SLAM examination of solar cells and solar cell welds. [Scanning Laser Acoustic Microscope
NASA Technical Reports Server (NTRS)
Stella, P. M.; Vorres, C. L.; Yuhas, D. E.
1981-01-01
The scanning laser acoustic microscope (SLAM) has been evaluated for non-destructive examination of solar cells and interconnector bonds. Using this technique, it is possible to view through materials in order to reveal regions of discontinuity such as microcracks and voids. Of particular interest is the ability to evaluate, in a unique manner, the bonds produced by parallel gap welding. It is possible to not only determine the area and geometry of the bond between the tab and cell, but also to reveal any microcracks incurred during the welding. By correlating the SLAM results with conventional techniques of weld evaluation a more confident weld parameter optimization can be obtained.
Microscopic evaluation and physiochemical analysis of Dillenia indica leaf
Kumar, S; Kumar, V; Prakash, Om
2011-01-01
Objective To study detail microscopic evaluation and physiochemical analysis of Dillenia indica (D. indica) leaf. Methods Fresh leaf sample and dried power of the leaf were studied macroscopically and microscopically. Preliminary phytochemical investigation of plant material was done. Other WHO recommended parameters for standardizations were also performed. Results The detail microscopy revealed the presence of anomocytic stomata, unicellular trichome, xylem fibres, calcium oxalate crystals, vascular bundles, etc. Leaf constants such as stomatal number, stomatal index, vein-islet number and veinlet termination numbers were also measured. Physiochemical parameters such as ash values, loss on drying, extractive values, percentage of foreign matters, swelling index, etc. were also determined. Preliminary phytochemical screening showed the presence of steroids, terpenoids, glycosides, fatty acids, flavonoids, phenolic compounds and carbohydrates. Conclusions The microscopic and physiochemical analysis of the D. indica leaf is useful in standardization for quality, purity and sample identification. PMID:23569789
Automatic Focus Adjustment of a Microscope
NASA Technical Reports Server (NTRS)
Huntsberger, Terrance
2005-01-01
AUTOFOCUS is a computer program for use in a control system that automatically adjusts the position of an instrument arm that carries a microscope equipped with an electronic camera. In the original intended application of AUTOFOCUS, the imaging microscope would be carried by an exploratory robotic vehicle on a remote planet, but AUTOFOCUS could also be adapted to similar applications on Earth. Initially control software other than AUTOFOCUS brings the microscope to a position above a target to be imaged. Then the instrument arm is moved to lower the microscope toward the target: nominally, the target is approached from a starting distance of 3 cm in 10 steps of 3 mm each. After each step, the image in the camera is subjected to a wavelet transform, which is used to evaluate the texture in the image at multiple scales to determine whether and by how much the microscope is approaching focus. A focus measure is derived from the transform and used to guide the arm to bring the microscope to the focal height. When the analysis reveals that the microscope is in focus, image data are recorded and transmitted.
Baco, Eduard; Rud, Erik; Vlatkovic, Ljiljana; Svindland, Aud; Eggesbø, Heidi B; Hung, Andrew J; Matsugasumi, Toru; Bernhard, Jean-Christophe; Gill, Inderbir S; Ukimura, Osamu
2015-02-01
Tumor contact length is defined as the amount of prostate cancer in contact with the prostatic capsule. We evaluated the ability of magnetic resonance imaging determined tumor contact length to predict microscopic extracapsular extension compared to existing predictors of extracapsular extension. We retrospectively analyzed the records of 111 consecutive patients with magnetic resonance imaging/ultrasound fusion targeted, biopsy proven prostate cancer who underwent radical prostatectomy from January 2010 to July 2013. Median patient age was 64 years and median prostate specific antigen was 8.9 ng/ml. Clinical stage was cT1 in 93 cases (84%) and cT2 in 18 (16%). Postoperative pathological analysis confirmed pT2 in 71 patients (64%) and pT3 in 40 (36%). We evaluated 1) in the radical prostatectomy specimen the correlation of microscopic extracapsular extension with pathological cancer volume, pathological tumor contact length and Gleason score, 2) the correlation between microscopic extracapsular extension and magnetic resonance imaging tumor contact length, and 3) the ability of preoperative variables to predict microscopic extracapsular extension. Logistic regression analysis revealed that pathological tumor contact length correlated better with microscopic extracapsular extension than the predictive power of pathological cancer volume (0.821 vs 0.685). The Spearman correlation between pathological and magnetic resonance imaging tumor contact length was r = 0.839 (p <0.0001). ROC AUC analysis revealed that magnetic resonance imaging tumor contact length outperformed cancer core involvement on targeted biopsy and the Partin tables to predict microscopic extracapsular extension (0.88 vs 0.70 and 0.63, respectively). At a magnetic resonance imaging tumor contact length threshold of 20 mm the accuracy for diagnosing microscopic extracapsular extension was superior to that of conventional magnetic resonance imaging criteria (82% vs 67%, p = 0.015). We developed a predicted probability plot curve of extracapsular extension according to magnetic resonance imaging tumor contact length. Magnetic resonance imaging determined tumor contact length could be a promising quantitative predictor of microscopic extracapsular extension. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Kang, Jung-Mi; Cho, Pyo-Yun; Moe, Mya; Lee, Jinyoung; Jun, Hojong; Lee, Hyeong-Woo; Ahn, Seong Kyu; Kim, Tae Im; Pak, Jhang Ho; Myint, Moe Kyaw; Lin, Khin; Kim, Tong-Soo; Na, Byoung-Kuk
2017-03-16
Accurate diagnosis of Plasmodium infection is crucial for prompt malaria treatment and surveillance. Microscopic examination has been widely applied as the gold standard for malaria diagnosis in most part of malaria endemic areas, but its diagnostic value has been questioned, particularly in submicroscopic malaria. In this study, the diagnostic performance of microscopic examination and nested polymerase chain reaction (PCR) was evaluated to establish optimal malaria diagnosis method in Myanmar. A total of 1125 blood samples collected from residents in the villages and towns located in Naung Cho, Pyin Oo Lwin, Tha Beik Kyin townships and Mandalay of Upper Myanmar were screened by microscopic examination and species-specific nested PCR method. Among the 1125 blood samples, 261 samples were confirmed to be infected with malaria by microscopic examination. Evaluation of the 1125 samples by species-specific nested PCR analysis revealed that the agreement between microscopic examination and nested PCR was 87.3% (261/299). Nested PCR successfully detected 38 Plasmodium falciparum or Plasmodium vivax infections, which were missed in microscopic examination. Microscopic examinations also either misdiagnosed the infected Plasmodium species, or did not detect mixed infections with different Plasmodium species in 31 cases. The nested PCR method is more reliable than conventional microscopic examination for the diagnosis of malaria infections, and this is particularly true in cases of mixed infections and submicroscopic infections. Given the observed higher sensitivity and specificity of nested PCR, the molecular method holds enormous promise in malaria diagnosis and species differentiation, and can be applied as an effective monitoring tool for malaria surveillance, control and elimination in Myanmar.
The response of single human cells to zero-gravity
NASA Technical Reports Server (NTRS)
Montgomery, P. O., Jr.; Cook, J. E.; Reynolds, R. C.; Paul, J. S.; Hayflick, L.; Stock, D.; Shulz, W. W.; Kimzey, S. L.; Thirolf, R. G.; Rogers, T.
1977-01-01
Microscopic and histochemical evaluations of human embrionic lung cells after exposure to zero-gravity are reported. Growth curves, DNA microspectrophotometry, phase microscopy, and ultrastructural studies of fixed cells revealed no effects on the cultures. Minor unexplained differences have been found in biochemical constituents of the samples.
Englhard, Anna S; Betz, Tom; Volgger, Veronika; Lankenau, Eva; Ledderose, Georg J; Stepp, Herbert; Homann, Christian; Betz, Christian S
2017-07-01
Endoscopic examination followed by tissue biopsy is the gold standard in the evaluation of lesions of the upper aerodigestive tract. However, it can be difficult to distinguish between healthy mucosa, dysplasia, and invasive carcinoma. Optical coherence tomography (OCT) is a non-invasive technique which acquires high-resolution, cross-sectional images of tissue in vivo. Integrated into a surgical microscope, it allows the intraoperative evaluation of lesions simultaneously with microscopic visualization. In a prospective case series, we evaluated the use of OCT integrated into a surgical microscope during microlaryngoscopy to help differentiating various laryngeal pathologies. 33 patients with laryngeal pathologies were examined with an OCT- microscope (OPMedT iOCT-camera, HS Hi-R 1000G-microscope, Haag-Streit Surgical GmbH, Wedel, Germany) during microlaryngoscopy. The suspected intraoperative diagnoses were compared to the histopathological reports of subsequent tissue biopsies. Hands-free non-contact OCT revealed high-resolution images of the larynx with a varying penetration depth of up to 1.2 mm and an average of 0.6 mm. Picture quality was variable. OCT showed disorders of horizontal tissue layering in dysplasias with a disruption of the basement membrane in carcinomas. When comparing the suspected diagnosis during OCT-supported microlaryngoscopy with histology, 79% of the laryngeal lesions could be correctly identified. Premalignant lesions were difficult to diagnose and falsely classified as carcinoma. OCT integrated into a surgical microscope seems to be a promising adjunct tool to discriminate pathologies of the upper aerodigestive tract intraoperatively. However, picture quality and penetration depth were variable. Although premalignant lesions were difficult to diagnose, the system proved overall helpful for the intraoperative discrimination of benign and malignant tumors. Further studies will be necessary to define its value in the future. Lasers Surg. Med. 49:490-497, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Chhabra, Sanjay; Yadav, Seema; Talwar, Sangeeta
2014-05-01
The study was aimed to acquire better understanding of C-shaped canal systems in mandibular second molar teeth through a clinical approach using sophisticated techniques such as surgical operating microscope and cone beam computed tomography (CBCT). A total of 42 extracted mandibular second molar teeth with fused roots and longitudinal grooves were collected randomly from native Indian population. Pulp chamber floors of all specimens were examined under surgical operating microscope and classified into four types (Min's method). Subsequently, samples were subjected to CBCT scan after insertion of K-files size #10 or 15 into each canal orifice and evaluated using the cross-sectional and 3-dimensional images in consultation with dental radiologist so as to obtain more accurate results. Minimum distance between the external root surface on the groove and initial file placed in the canal was also measured at different levels and statistically analyzed. Out of 42 teeth, maximum number of samples (15) belonged to Type-II category. A total of 100 files were inserted in 86 orifices of various types of specimens. Evaluation of the CBCT scan images of the teeth revealed that a total of 21 canals were missing completely or partially at different levels. The mean values for the minimum thickness were highest at coronal followed by middle and apical third levels in all the categories. Lowest values were obtained for teeth with Type-III category at all three levels. The present study revealed anatomical variations of C-shaped canal system in mandibular second molars. The prognosis of such complex canal anatomies can be improved by simultaneous employment of modern techniques such as surgical operating microscope and CBCT.
Kim, Dong Wook; Kim, Hak Jin; Lee, Jun Woo
2010-06-01
OK-432 is known to be a potent sclerosant of cystic lesions. The purpose of this study was to evaluate both its safety and pathologic effects after the infusion of OK-432 into the peritoneal cavity of rats. Twenty male rats were used in this study. Twelve rats were infused intraperitoneally with 0.2 Klinishe Einheit of OK-432 melted in 2 mL of normal saline (group 1: the treated group); four rats each were infused intraperitoneally with 0.5 mL of 99% ethanol (group 2) and normal saline (group 3), and served as the control groups. An abdominal ultrasonographic examination was performed both before and after the infusions in all rats. Three rats in group 1 and one rat in each of groups 2 and 3 were sacrificed each week following the infusion. Gross and microscopic evaluations of the peritoneum and abdominal cavity were performed on each rat. In group 1, the abdomen was clear on gross inspection and the peritoneum was unremarkable on microscopic examination. In group 2, mild-to-moderate peritoneal adhesions were revealed grossly, and inflammation and fibrosis of the peritoneum were demonstrated microscopically. In group 3, no specific abnormalities were noted on gross or microscopic examinations. Leakage or abnormal infusion of OK-432 solution into the peritoneal cavity during sclerotherapy of intra-abdominal or retroperitoneal cystic lesions does not result in any significant complications. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Recently, a bottle of ERM bacterin that was approximately 35-years-old and labeled by Wildlife Vaccines with a serial number of 236 and an expiration date of October 18, 1982 was discovered in a storage closet at room temperature at the Clear Springs Foods Research Division. Microscopic evaluation a...
Investigating Dissolution and Precipitation Phenomena with a Smartphone Microscope
ERIC Educational Resources Information Center
Lumetta, Gregg J.; Arcia, Edgar
2016-01-01
A novel smartphone microscope can be used to observe the dissolution and crystallization of sodium chloride at a microscopic level. Observation of these seemingly simple phenomena through the microscope at 100× magnification can actually reveal some surprising behavior. These experiments offer the opportunity to discuss some basic concepts such as…
Basques, Bryce A.; Golinvaux, Nicholas S.; Bohl, Daniel D.; Yacob, Alem; Toy, Jason O.; Varthi, Arya G.; Grauer, Jonathan N.
2014-01-01
Study Design Retrospective database review. Objective To evaluate whether microscope use during spine procedures is associated with increased operating room times or increased risk of infection. Summary of Background Data Operating microscopes are commonly used in spine procedures. It is debated whether the use of an operating microscope increases operating room time or confers increased risk of infection. Methods The American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) database, which includes data from over 370 participating hospitals, was used to identify patients undergoing elective spinal procedures with and without an operating microscope for the years 2011 and 2012. Bivariate and multivariate linear regressions were used to test the association between microscope use and operating room times. Bivariate and multivariate logistic regressions were similarly conducted to test the association between microscope use and infection occurrence within 30 days of surgery. Results A total of 23,670 elective spine procedures were identified, of which 2,226 (9.4%) used an operating microscope. The average patient age was 55.1 ± 14.4 years. The average operative time (incision to closure) was 125.7 ± 82.0 minutes. Microscope use was associated with minor increases in preoperative room time (+2.9 minutes, p=0.013), operative time (+13.2 minutes, p<0.001), and total room time (+18.6 minutes, p<0.001) on multivariate analysis. A total of 328 (1.4%) patients had an infection within 30 days of surgery. Multivariate analysis revealed no significant difference between the microscope and non-microscope groups for occurrence of any infection, superficial surgical site infection (SSI), deep SSI, organ space infection, or sepsis/septic shock, regardless of surgery type. Conclusions We did not find operating room times or infection risk to be significant deterrents for use of an operating microscope during spine surgery. PMID:25188600
Rothschild, Bruce
2016-05-01
The ability of health care professionals to provide patient care is potentially compromised when predicated on untested, although longstanding, perspectives. One such example is urinalysis testing, which has been currently simplified to use only urine testing strips for detection of microscopic hematuria. To determine whether urine testing strips are sufficient for identification of clinically significant findings in urinalysis. To determine the presence of microscopic hematuria, I examined a collection of urine specimens that had tested heme negative during the 3-month study period. Of the 342 patients from whom urine specimens were examined during this interval, 50 had microscopic hematuria, despite having tested negative for heme via urine testing strip. Also, 30% were not receiving any medication known to produce microscopic hematuria, and 18% had clinically significant pathology. Diagnosis of significant clinical pathologic manifestations would have been compromised had microscopic examination not been performed on the urine specimens from the cohort individuals. Examination of the novel approach of including microscopic examination of specimens in a specific clinical situation challenges the dominant paradigm of reliance on assaying using urine testing strips only, revealing that the current method is not only unreliable for determining microscopic hematuria but also is less than optimal in general clinical practice. The findings of this study provide evidence of the importance of microscopic evaluation as a routine component of urinalysis. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Eyelid skin as a potential site for drug delivery to conjunctiva and ocular tissues.
See, Gerard Lee; Sagesaka, Ayano; Sugasawa, Satoko; Todo, Hiroaki; Sugibayashi, Kenji
2017-11-25
The feasibility of topical application onto the (lower) eyelid skin to deliver hydrophilic and lipophilic compounds into the conjunctiva and ocular tissues was evaluated by comparing with conventional eye drop application. Skin permeation and the concentration of several model compounds, and skin impedance were determined utilizing eyelid skin from hairless rats, as well as abdominal skin in the same animals for comparison. In vitro static diffusion cells were used to assess the skin permeation in order to provide key insights into the relationship between the skin sites and drugs. The obtained results revealed that drug permeation through the eyelid skin was much higher than that through abdominal skin regardless of the drug lipophilicity. Specifically, diclofenac sodium salt and tranilast exhibited approximately 6-fold and 11-fold higher permeability coefficients, respectively, through eyelid skin compared with abdominal skin. Histomorphological evaluation and in vivo distribution of model fluorescent dyes were also examined in the conjunctiva and skin after eyelid administration by conventional microscope and confocal laser scanning microscope analyses. The result revealed that eyelid skin has a thinner stratum corneum, thereby showing lower impedance, which could be the reason for the higher drug permeation through eyelid skin. Comparative evaluation of lipophilic and hydrophilic model compounds administered via the eyelid skin over 8h revealed stronger fluorescence intensity in the skin and surrounding tissues compared with eye drop administration. These results suggested that the (lower) eyelid skin is valuable as a prospective site for ophthalmic medicines. Copyright © 2017 Elsevier B.V. All rights reserved.
Madry, Henning; Ziegler, Raphaela; Orth, Patrick; Goebel, Lars; Ong, Mei Fang; Kohn, Dieter; Cucchiarini, Magali; Pape, Dietrich
2013-01-01
To evaluate whether medial open wedge high tibial osteotomy (HTO) results in structural and biochemical changes in the lateral meniscus in adult sheep. Three experimental groups with biplanar osteotomies of the right proximal tibiae were tested: (a) closing wedge HTO resulting in 4.5° of tibial varus, (b) open wedge HTO resulting in 4.5° of tibial valgus (standard correction) and (c) open wedge HTO resulting in 9.5° of valgus (overcorrection), each of which was compared to the contralateral knees with normal limb axes. After 6 months, the lateral menisci were macroscopically and microscopically evaluated. The proteoglycan and DNA contents of the red-red and white-white zones of the anterior, middle and posterior third were determined. Semiquantitative macroscopic and microscopic grading revealed no structural differences between groups. The red-red zone of the middle third of the lateral menisci of animals that underwent overcorrection exhibited a significant 0.7-fold decrease in mean DNA contents compared with the control knee without HTO (P = 0.012). Comparative estimation of the DNA and proteoglycan contents and proteoglycan/DNA ratios of all other parts and zones of the lateral menisci did not reveal significant differences between groups. Open wedge HTO does not lead to significant macroscopic and microscopic structural changes in the lateral meniscus after 6 months in vivo. Overcorrection significantly decreases the proliferative activity of the cells in the red-red zone of the middle third in the sheep model.
NASA Astrophysics Data System (ADS)
Viard, Clément; Nakashima, Kiyoko; Lamory, Barbara; Pâques, Michel; Levecq, Xavier; Château, Nicolas
2011-03-01
This research is aimed at characterizing in vivo differences between healthy and pathological retinal tissues at the microscopic scale using a compact adaptive optics (AO) retinal camera. Tests were performed in 120 healthy eyes and 180 eyes suffering from 19 different pathological conditions, including age-related maculopathy (ARM), glaucoma and rare diseases such as inherited retinal dystrophies. Each patient was first examined using SD-OCT and infrared SLO. Retinal areas of 4°x4° were imaged using an AO flood-illumination retinal camera based on a large-stroke deformable mirror. Contrast was finally enhanced by registering and averaging rough images using classical algorithms. Cellular-resolution images could be obtained in most cases. In ARM, AO images revealed granular contents in drusen, which were invisible in SLO or OCT images, and allowed the observation of the cone mosaic between drusen. In glaucoma cases, visual field was correlated to changes in cone visibility. In inherited retinal dystrophies, AO helped to evaluate cone loss across the retina. Other microstructures, slightly larger in size than cones, were also visible in several retinas. AO provided potentially useful diagnostic and prognostic information in various diseases. In addition to cones, other microscopic structures revealed by AO images may also be of interest in monitoring retinal diseases.
High throughput secondary electron imaging of organic residues on a graphene surface
NASA Astrophysics Data System (ADS)
Zhou, Yangbo; O'Connell, Robert; Maguire, Pierce; Zhang, Hongzhou
2014-11-01
Surface organic residues inhibit the extraordinary electronic properties of graphene, hindering the development of graphene electronics. However, fundamental understanding of the residue morphology is still absent due to a lack of high-throughput and high-resolution surface characterization methods. Here, we demonstrate that secondary electron (SE) imaging in the scanning electron microscope (SEM) and helium ion microscope (HIM) can provide sub-nanometer information of a graphene surface and reveal the morphology of surface contaminants. Nanoscale polymethyl methacrylate (PMMA) residues are visible in the SE imaging, but their contrast, i.e. the apparent lateral dimension, varies with the imaging conditions. We have demonstrated a quantitative approach to readily obtain the physical size of the surface features regardless of the contrast variation. The fidelity of SE imaging is ultimately determined by the probe size of the primary beam. HIM is thus evaluated to be a superior SE imaging technique in terms of surface sensitivity and image fidelity. A highly efficient method to reveal the residues on a graphene surface has therefore been established.
Ma, Junlong; Wang, Chengbin; Yue, Jiaxin; Li, Mianyang; Zhang, Hongrui; Ma, Xiaojing; Li, Xincui; Xue, Dandan; Qing, Xiaoyan; Wang, Shengjiang; Xiang, Daijun; Cong, Yulong
2013-01-01
Several automated urine sediment analyzers have been introduced to clinical laboratories. Automated microscopic pattern recognition is a new technique for urine particle analysis. We evaluated the analytical and diagnostic performance of the UriSed automated microscopic analyzer and compared with manual microscopy for urine sediment analysis. Precision, linearity, carry-over, and method comparison were carried out. A total of 600 urine samples sent for urinalysis were assessed using the UriSed automated microscopic analyzer and manual microscopy. Within-run and between-run precision of the UriSed for red blood cells (RBC) and white blood cells (WBC) were acceptable at all levels (CV < 20%). Within-run and between-run imprecision of the UriSed testing for cast, squamous epithelial cells (EPI), and bacteria (BAC) were good at middle level and high level (CV < 20%). The linearity analysis revealed substantial agreement between the measured value and the theoretical value of the UriSed for RBC, WBC, cast, EPI, and BAC (r > 0.95). There was no carry-over. RBC, WBC, and squamous epithelial cells with sensitivities and specificities were more than 80% in this study. There is substantial agreement between the UriSed automated microscopic analyzer and the manual microscopy methods. The UriSed provides for a rapid turnaround time.
Basques, Bryce A; Golinvaux, Nicholas S; Bohl, Daniel D; Yacob, Alem; Toy, Jason O; Varthi, Arya G; Grauer, Jonathan N
2014-10-15
Retrospective database review. To evaluate whether microscope use during spine procedures is associated with increased operating room times or increased risk of infection. Operating microscopes are commonly used in spine procedures. It is debated whether the use of an operating microscope increases operating room time or confers increased risk of infection. The American College of Surgeons National Surgical Quality Improvement Program database, which includes data from more than 370 participating hospitals, was used to identify patients undergoing elective spinal procedures with and without the use of an operating microscope for the years 2011 and 2012. Bivariate and multivariate linear regressions were used to test the association between microscope use and operating room times. Bivariate and multivariate logistic regressions were similarly conducted to test the association between microscope use and infection occurrence within 30 days of surgery. A total of 23,670 elective spine procedures were identified, of which 2226 (9.4%) used an operating microscope. The average patient age was 55.1±14.4 years. The average operative time (incision to closure) was 125.7±82.0 minutes.Microscope use was associated with minor increases in preoperative room time (+2.9 min, P=0.013), operative time (+13.2 min, P<0.001), and total room time (+18.6 min, P<0.001) on multivariate analysis.A total of 328 (1.4%) patients had an infection within 30 days of surgery. Multivariate analysis revealed no significant difference between the microscope and nonmicroscope groups for occurrence of any infection, superficial surgical site infection, deep surgical site infection, organ space infection, or sepsis/septic shock, regardless of surgery type. We did not find operating room times or infection risk to be significant deterrents for use of an operating microscope during spine surgery. 3.
Costa, Walder; Silva, Alcino Lázaro da; Costa, Gustavo Rocha; Vidigal, Paula Vieira Teixeira; Pereira, Fernando Henrique
2015-07-01
To evaluate the effects of isoxsuprine and nicotine on TRAM. Forty eight 48 Wistar rats distributed into four Groups (n=12). All rats received medication managed daily for 20 days: saline solution (SA), nicotine solution (NI), isoxsuprine solution (IS) and nicotine solution (NI) + isoxsuprine solution (IS). On day 21st the rats were submitted to the caudally based, right unipedicled TRAM flap and after 48 hours, made the macroscopic evaluation of the surface of the flap, photographic documentation and collection of material for histology. Data from macroscopic evaluation were analyzed by ANOVA and microscopic evaluation by Kruskal-Wallis test, with significance level of 5%. In the macroscopic evaluation of isoxsuprine Group retail presented absolute numbers: final area (p=0.001*) and viable area (p=0.006*) with the highest values; necrosis (p=0.001*) had the lowest value. Microscopic examination revealed no significant findings in the study of TRAM under the action of isoxsuprine and nicotine to the percentage of necrosis in the left and right cranial and caudal regions. There was significant improvement in viability of TRAM using the isoxsuprine solution alone. No influence using nicotine alone and in association with isoxsuprine.
DO-increasing effects of a microscopic bubble generating system in a fish farm.
Endo, Akira; Srithongouthai, Sarawut; Nashiki, Hisatsune; Teshiba, Ichiro; Iwasaki, Takaaki; Hama, Daigo; Tsutsumi, Hiroaki
2008-01-01
We have developed a "microscopic bubble generating system for the fish farm" and evaluated its ability to improve the quality of seawater and costs of it in marine cages of red sea bream (Pagrus major) in Kusuura Bay, Japan. Our results revealed that DO concentration of bubbling net pens increased and became significantly higher than the level outside the net pen (between 0.52 and 0.87 mg/L), and the whole water column was nearly saturated. Temperatures of the bubbling net pens decreased slightly between 0.08 and 0.12 degrees C in all the layers. Furthermore, micro-bubbles seemed to reach the deeper water due to the downward flow and diffusion. This study demonstrated that the microscopic bubble generating system developed in our research project could increase efficiently the dissolved oxygen concentration throughout all water layers of the fish farm. A capital and operation costs of the system is recoverable within a year.
NASA Astrophysics Data System (ADS)
Tian, Chenguang; Lu, Huimin; Zhao, Liyuan
The super-light LA141 (Mg-14%Li-1%Al) alloy was produced and processed by high-pressure torsion (HPT) under the imposed pressure of 3 GPa and different shear strains γ through 3, 6, 9 and 12 turns at room temperature (RT). The microstructure evolution of the alloy during the HPT treatment was investigated by transmission electron microscope (TEM) and optical microscope (OM). It turned out that the grains were substantially refined, and the optical microscope revealed that the grains of HPT processed samples at the edge of the disc were finer by comparison with the ones near the center of the disc. Later, Vickers indentation analysis was used to evaluate the micro-hardness of deformed samples, and tension test was employed to obtain the strength and elongation at room temperature. The results indicated that the micro-hardness and tensile strength had increased to a certain extent, and the elongation had been significantly improved.
4D microscope-integrated OCT improves accuracy of ophthalmic surgical maneuvers
NASA Astrophysics Data System (ADS)
Carrasco-Zevallos, Oscar; Keller, Brenton; Viehland, Christian; Shen, Liangbo; Todorich, Bozho; Shieh, Christine; Kuo, Anthony; Toth, Cynthia; Izatt, Joseph A.
2016-03-01
Ophthalmic surgeons manipulate micron-scale tissues using stereopsis through an operating microscope and instrument shadowing for depth perception. While ophthalmic microsurgery has benefitted from rapid advances in instrumentation and techniques, the basic principles of the stereo operating microscope have not changed since the 1930's. Optical Coherence Tomography (OCT) has revolutionized ophthalmic imaging and is now the gold standard for preoperative and postoperative evaluation of most retinal and many corneal procedures. We and others have developed initial microscope-integrated OCT (MIOCT) systems for concurrent OCT and operating microscope imaging, but these are limited to 2D real-time imaging and require offline post-processing for 3D rendering and visualization. Our previously presented 4D MIOCT system can record and display the 3D surgical field stereoscopically through the microscope oculars using a dual-channel heads-up display (HUD) at up to 10 micron-scale volumes per second. In this work, we show that 4D MIOCT guidance improves the accuracy of depth-based microsurgical maneuvers (with statistical significance) in mock surgery trials in a wet lab environment. Additionally, 4D MIOCT was successfully performed in 38/45 (84%) posterior and 14/14 (100%) anterior eye human surgeries, and revealed previously unrecognized lesions that were invisible through the operating microscope. These lesions, such as residual and potentially damaging retinal deformation during pathologic membrane peeling, were visualized in real-time by the surgeon. Our integrated system provides an enhanced 4D surgical visualization platform that can improve current ophthalmic surgical practice and may help develop and refine future microsurgical techniques.
Electron microscopic evaluation of a gold glaucoma micro shunt after explantation.
Berk, Thomas A; Tam, Diamond Y; Werner, Liliana; Mamalis, Nick; Ahmed, Iqbal Ike K
2015-03-01
We present a case of an explanted gold glaucoma micro shunt (GMS Plus) and the subsequent light and electron microscopic analyses. The shunt was implanted in a patient with medically refractive glaucoma. The intraocular pressure (IOP) was stable at 12 mm Hg 6 months postoperatively but spiked to 26 mm Hg 6 months later; membranous growth was visible on the implant gonioscopically. A second gold micro shunt was placed 2 years after the first. The IOP was 7 mm Hg 1 week postoperatively but increased to 23 mm Hg 3 weeks later; similar membranous growth was visible on this implant. One of the shunts was explanted, and light and scanning electron microscopic analyses revealed encapsulation around the shunt exterior and connective tissue invasion of the microstructure. This represents the first electron microscopic analysis of an explanted gold glaucoma micro shunt and the first unequivocal images of the fibrotic pseudo-capsule traversing its microchannels and fenestrations. Dr. Ahmed is a consultant to and has received research grants from Solx, Inc. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Dental enamel defect diagnosis through different technology-based devices.
Kobayashi, Tatiana Yuriko; Vitor, Luciana Lourenço Ribeiro; Carrara, Cleide Felício Carvalho; Silva, Thiago Cruvinel; Rios, Daniela; Machado, Maria Aparecida Andrade Moreira; Oliveira, Thais Marchini
2018-06-01
Dental enamel defects (DEDs) are faulty or deficient enamel formations of primary and permanent teeth. Changes during tooth development result in hypoplasia (a quantitative defect) and/or hypomineralisation (a qualitative defect). To compare technology-based diagnostic methods for detecting DEDs. Two-hundred and nine dental surfaces of anterior permanent teeth were selected in patients, 6-11 years of age, with cleft lip with/without cleft palate. First, a conventional clinical examination was conducted according to the modified Developmental Defects of Enamel Index (DDE Index). Dental surfaces were evaluated using an operating microscope and a fluorescence-based device. Interexaminer reproducibility was determined using the kappa test. To compare groups, McNemar's test was used. Cramer's V test was used for comparing the distribution of index codes obtained after classification of all dental surfaces. Cramer's V test revealed statistically significant differences (P < .0001) in the distribution of index codes obtained using the different methods; the coefficients were 0.365 for conventional clinical examination versus fluorescence, 0.961 for conventional clinical examination versus operating microscope and 0.358 for operating microscope versus fluorescence. The sensitivity of the operating microscope and fluorescence method was statistically significant (P = .008 and P < .0001, respectively). Otherwise, the results did not show statistically significant differences in accuracy and specificity for either the operating microscope or the fluorescence methods. This study suggests that the operating microscope performed better than the fluorescence-based device and could be an auxiliary method for the detection of DEDs. © 2017 FDI World Dental Federation.
NASA Astrophysics Data System (ADS)
Quintavalla, M.; Pozzi, P.; Verhaegen, Michelle; Bijlsma, Hielke; Verstraete, Hans; Bonora, S.
2018-02-01
Adaptive Optics (AO) has revealed as a very promising technique for high-resolution microscopy, where the presence of optical aberrations can easily compromise the image quality. Typical AO systems however, are almost impossible to implement on commercial microscopes. We propose a simple approach by using a Multi-actuator Adaptive Lens (MAL) that can be inserted right after the objective and works in conjunction with an image optimization software allowing for a wavefront sensorless correction. We presented the results obtained on several commercial microscopes among which a confocal microscope, a fluorescence microscope, a light sheet microscope and a multiphoton microscope.
Lauten, Alexander; Laube, Adrian; Schubert, Harald; Bischoff, Sabine; Nietzsche, Sandor; Horstkötter, Kim; Poudel-Bochmann, Bhawana; Franz, Marcus; Lichtenberg, Artur; Figulla, Hans R; Akhyari, Payam
2015-01-01
Caval valve implantation has been suggested for transcatheter treatment of severe tricuspid regurgitation (TR). Combining the interventional technique with the promising surgical experience with decellularized valves, we sought to evaluate the functional and structural outcome of decellularized pericardial tissue valves (dTVs) in the low-pressure venous circulation in a chronic model of TR. Sixteen pericardial tissue valves were heterotopically implanted in the inferior and superior vena cava in a sheep model (54-98 kg; median 74.5 kg, n = 8) of severe TR. The devices were assembled using self-expanding nitinol stents and bovine pericardia decellularized by a detergent-based protocol (group dTV; n = 8). Glutaraldehyde-fixed pericardial tissue valves served as control (GaTV, n = 8). After 6 months, device function and structural maturation were analyzed using echocardiographic, histologic, immunohistologic, and electron microscopic approaches. After implantation, cardiac output increased significantly from 3.7 ± 1.1 l/min to 4.8 ± 1.1 l/min (P < 0.05) and competent valve function was verified by angiography. At 6 months, angiographic and echocardiographic evaluation revealed moderate to severe regurgitation in all GaTV. In contrast, five of the eight dTVs functioned well with only minor regurgitation. In these animals, autopsy revealed preserved valve structure with tender leaflets without signs of thrombosis or calcification. Conversely, GaTV showed severe degeneration with large calcification areas. Microscopic and histologic analysis confirmed endothelial repopulation in both valve types. However, additional interstitial reseeding was observed in decellularized valves. In the venous circulation in severe TR, decellularized valves show superior functional performance compared to Ga-fixed tissue valves. Macroscopic and microscopic analyses suggest preserved structural integrity and advanced endothelial and interstitial repopulation with evidence of less degradation in dTV. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.
Ojha, Saroj Kumar; Javdekar, Sadashiv Bhaskar; Dhir, Sangeeta
2015-01-01
Context: Plaque control has been shown to be pivotal in maintaining the optimal periodontal health. Mechanical plaque control is the most popular option for establishing the optimal oral health. Toothbrushes have been the novel tool for mechanical cleansing. However, the abrasive potential of the toothbrushes on the enamel surface is an area in gray. Aims: The aim of this in vitro study is to evaluate the abrasivity of the toothbrush versus the velcro fasteners. Materials and Methods: The mounted teeth of both the groups were subjected to abrasion test, and the tooth surfaces were observed for the possible abrasions from the oscillating strokes (toothbrush) and frictional contacts (hook and loop velcro) and examined under the scanning electron microscope. Results: Comparative assessment of both velcro (hook and loop) and toothbrush bristles did not reveal any evidence of abrasion on the tooth specimens. Conclusions: Veclro fasteners are safe and qualitatively at par to the manual toothbrush for their efficacy and efficiency in teeth cleansing PMID:26229264
NASA Astrophysics Data System (ADS)
Ebrahimi, Izadyar; Gashti, Mazeyar Parvinzadeh
2018-07-01
In this study, we focused on the synthesis of polypyrrole-MWCNT-Ag composites and we evaluated their electrical properties to determine the electromagnetic interference shielding performance. We reduced silver nanoparticles in composites using two different in situ methods: UV-reduction and chemical deposition. Composites were characterized using spectroscopic and microscopic tools for evaluation of the chemical, morphological, electrical conductivity and electromagnetic shielding effectiveness. Results from Fourier transform infrared spectroscopy and dispersive Raman microscope showed chemical interactions between silver and the polypyrrole-MWCNT composite due to the charge-transfer within the structure. X-ray diffraction confirmed appearance of two new peaks for silver nanoparticles embedded in polypyrrole-MWCNT independent to reduction method. According to microscopy images, silver nanoparticles were homogenously distributed at the PPy-MWCNTs interfaces by UV reduction, while, chemical reduction resulted to deposition of silver within the PPy matrix. Finally, our results revealed that the polypyrrole-MWCNT-Ag composite produced via UV-reduction has higher electrical conductivity and shielding effectiveness in comparison to chemically reduced one.
Gardiner, David W; Baines, Frances M; Pandher, Karamjeet
2009-12-01
A male ball python (Python regius) and a female blue tongue skink (Tiliqua spp.) of unknown age were evaluated for anorexia, lethargy, excessive shedding, corneal opacity (python), and weight loss (skink) of approximately three weeks' duration. These animals represented the worst affected animals from a private herpetarium where many animals exhibited similar signs. At necropsy, the python had bilateral corneal opacity and scattered moderate dysecdysis. The skink had mild dysecdysis, poor body condition, moderate intestinal nematodiasis, and mild liver atrophy. Microscopic evaluation revealed epidermal erosion and ulceration, with severe epidermal basal cell degeneration and necrosis, and superficial dermatitis (python and skink). Severe bilateral ulcerative keratoconjunctivitis with bacterial colonization was noted in the ball python. Microscopic findings within the skin and eyes were suggestive of ultraviolet (UV) radiation damage or of photodermatitis and photokeratoconjunctivitis. Removal of the recently installed new lamps from the terrariums of the surviving reptiles resulted in resolution of clinical signs. Evaluation of a sample lamp of the type associated with these cases revealed an extremely high UV output, including very-short-wavelength UVB, neither found in natural sunlight nor emitted by several other UVB lamps unassociated with photokeratoconjunctivitis. Exposure to high-intensity and/or inappropriate wavelengths of UV radiation may be associated with significant morbidity, and even mortality, in reptiles. Veterinarians who are presented with reptiles with ocular and/or cutaneous disease of unapparent cause should fully evaluate the specifics of the vivarium light sources. Further research is needed to determine the characteristics of appropriate and of toxic UV light for reptiles kept in captivity.
Qiang, Yujie; Guo, Lei; Zhang, Shengtao; Li, Wenpo; Yu, Shanshan; Tan, Jianhong
2016-01-01
The inhibitive ability of 2,6-diaminopyridine, tartaric acid and their synergistic effect towards mild steel corrosion in 0.5 M HCl solution was evaluated at various concentrations using potentiodynamic polarization measurements, electrochemical impedance spectroscopy (EIS), and weight loss experiments. Corresponding surfaces of mild steel were examined by atomic force microscope (AFM), field emission scanning electron microscope (FE-SEM), energy dispersive X-ray spectroscopy (EDX), X-ray photoelectron spectroscopy (XPS) analysis. The experimental results are in good agreement and reveal a favorable synergistic effect of 2,6-diaminopyridine with tartaric acid, which could protect mild steel from corrosion effectively. Besides, quantum chemical calculations and Monte Carlo simulation were used to clarify the inhibition mechanism of the synergistic effect. PMID:27628901
Cionni, Robert J; Pei, Ron; Dimalanta, Ramon; Lubeck, David
2015-08-01
To evaluate the intensity and stability of the red reflex produced by ophthalmic surgical microscopes with nearly-collimated versus focused illumination systems and to assess surgeon preference in a simulated surgical setting. This two-part evaluation consisted of postproduction surgical video analysis of red reflex intensity and a microscope use and preference survey completed by 13 experienced cataract surgeons. Survey responses were based on bench testing and experience in a simulated surgical setting. A microscope with nearly-collimated beam illumination and two focused beam microscopes were assessed. Red reflex intensity and stability were greater with the nearly-collimated microscope illumination system. In the bench testing survey, surgeons reported that the red reflex was maintained over significantly greater distances away from pupillary center, and depth of focus was numerically greater with nearly-collimated illumination relative to focused illumination. Most participating surgeons (≥64%) reported a preference for the microscope with nearly-collimated illumination with regard to red reflex stability, depth of focus, visualization, surgical working distance, and perceived patient comfort. The microscope with nearly-collimated illumination produced a more intense and significantly more stable red reflex and was preferred overall by more surgeons. This is the first report of an attempt to quantify red reflex intensity and stability and to evaluate surgically-relevant parameters between microscope systems. The data and methods presented here may provide a basis for future studies attempting to quantify differences between surgical microscopes that may affect surgeon preference and microscope use in ophthalmic surgery.
Investigating Dissolution and Precipitation Phenomena with a Smartphone Microscope
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lumetta, Gregg J.; Arcia, Edgar
A novel smartphone microscope can be used to observe the dissolution and crystallization of sodium chloride at a microscopic level. Observation of these seemingly simple phenomena through the microscope at 100× magnification can actually reveal some surprising behavior. These experiments offer the opportunity to discuss some basic concepts such as how the morphological features of the crystals dictates how the dissolution process proceeds, and how materials can be purified by re-crystallization techniques.
Green tea extract induces protective autophagy in A549 non-small lung cancer cell line.
Izdebska, Magdalena; Klimaszewska-Wiśniewska, Anna; Hałas, Marta; Gagat, Maciej; Grzanka, Alina
2015-12-31
For many decades, polyphenols, including green tea extract catechins, have been reported to exert multiple anti-tumor activities. However, to date the mechanisms of their action have not been completely elucidated. Thus, the aim of this study was to assess the effect of green tea extract on non-small lung cancer A549 cells. A549 cells following treatment with GTE were analyzed using the inverted light and fluorescence microscope. In order to evaluate cell sensitivity and cell death, the MTT assay and Tali image-based cytometer were used, respectively. Ultrastructural alterations were assessed using a transmission electron microscope. The obtained data suggested that GTE, even at the highest dose employed (150 μM), was not toxic to A549 cells. Likewise, the treatment with GTE resulted in only a very small dose-dependent increase in the population of apoptotic cells. However, enhanced accumulation of vacuole-like structures in response to GTE was seen at the light and electron microscopic level. Furthermore, an increase in the acidic vesicular organelles and LC3-II puncta formation was observed under the fluorescence microscope, following GTE treatment. The analysis of the functional status of autophagy revealed that GTE-induced autophagy may provide self-protection against its own cytotoxicity, since we observed that the blockage of autophagy by bafilomycin A1 decreased the viability of A549 cells and potentiated necrotic cell death induction in response to GTE treatment. Collectively, our results revealed that A549 cells are insensitive to both low and high concentrations of the green tea extract, probably due to the induction of cytoprotective autophagy. These data suggest that a potential utility of GTE in lung cancer therapy may lie in its synergistic combinations with drugs or small molecules that target autophagy, rather than in monotherapy.
Seasonal variation of plankton communities influenced by environmental factors in an artificial lake
NASA Astrophysics Data System (ADS)
Li, Xuemei; Yu, Yuhe; Zhang, Tanglin; Feng, Weisong; Ao, Hongyi; Yan, Qingyun
2012-05-01
We evaluated the seasonal variation in plankton community composition in an artificial lake. We conducted microscopic analysis and denaturing gradient gel electrophoresis (DGGE) of PCR-amplified partial 16S rRNA and 18S rRNA genes to characterize the plankton community. The clustering of unweighted pair group method with arithmetic mean (UPGMA) was then used to investigate the similarity of these plankton communities. DGGE fingerprinting revealed that samples collected at the different sites within a season shared high similarity and were generally grouped together. In contrast, we did not observe any seasonal variation based on microscopic analysis. Redundancy analysis (RDA) of the plankton operational taxonomic units (OTUs) in relation to environmental factors revealed that transparency was negatively correlated with the first axis ( R=-0.931), and temperature and total phosphorus (TP) were positively correlated with the first axis ( R=0.736 and R=0.660, respectively). In conclusion, plankton communities in the artificial lake exhibited significant seasonal variation. Transparency, phosphorus and temperature appear to be the major factors driving the differences in plankton composition.
McCall, Brian; Olsen, Randall J; Nelles, Nicole J; Williams, Dawn L; Jackson, Kevin; Richards-Kortum, Rebecca; Graviss, Edward A; Tkaczyk, Tomasz S
2014-03-01
A prototype miniature objective that was designed for a point-of-care diagnostic array microscope for detection of Mycobacterium tuberculosis and previously fabricated and presented in a proof of concept is evaluated for its effectiveness in detecting acid-fast bacteria. To evaluate the ability of the microscope to resolve submicron features and details in the image of acid-fast microorganisms stained with a fluorescent dye, and to evaluate the accuracy of clinical diagnoses made with digital images acquired with the objective. The lens prescription data for the microscope design are presented. A test platform is built by combining parts of a standard microscope, a prototype objective, and a digital single-lens reflex camera. Counts of acid-fast bacteria made with the prototype objective are compared to counts obtained with a standard microscope over matched fields of view. Two sets of 20 smears, positive and negative, are diagnosed by 2 pathologists as sputum smear positive or sputum smear negative, using both a standard clinical microscope and the prototype objective under evaluation. The results are compared to a reference diagnosis of the same sample. More bacteria are counted in matched fields of view in digital images taken with the prototype objective than with the standard clinical microscope. All diagnostic results are found to be highly concordant. An array microscope built with this miniature lens design will be able to detect M tuberculosis with high sensitivity and specificity.
Cionni, Robert J.; Pei, Ron; Dimalanta, Ramon; Lubeck, David
2015-01-01
Purpose To evaluate the intensity and stability of the red reflex produced by ophthalmic surgical microscopes with nearly-collimated versus focused illumination systems and to assess surgeon preference in a simulated surgical setting. Methods This two-part evaluation consisted of postproduction surgical video analysis of red reflex intensity and a microscope use and preference survey completed by 13 experienced cataract surgeons. Survey responses were based on bench testing and experience in a simulated surgical setting. A microscope with nearly-collimated beam illumination and two focused beam microscopes were assessed. Results Red reflex intensity and stability were greater with the nearly-collimated microscope illumination system. In the bench testing survey, surgeons reported that the red reflex was maintained over significantly greater distances away from pupillary center, and depth of focus was numerically greater with nearly-collimated illumination relative to focused illumination. Most participating surgeons (≥64%) reported a preference for the microscope with nearly-collimated illumination with regard to red reflex stability, depth of focus, visualization, surgical working distance, and perceived patient comfort. Conclusions The microscope with nearly-collimated illumination produced a more intense and significantly more stable red reflex and was preferred overall by more surgeons. Translational Relevance This is the first report of an attempt to quantify red reflex intensity and stability and to evaluate surgically-relevant parameters between microscope systems. The data and methods presented here may provide a basis for future studies attempting to quantify differences between surgical microscopes that may affect surgeon preference and microscope use in ophthalmic surgery. PMID:26290778
Unsteady Crystal Growth Due to Step-Bunch Cascading
NASA Technical Reports Server (NTRS)
Vekilov, Peter G.; Lin, Hong; Rosenberger, Franz
1997-01-01
Based on our experimental findings of growth rate fluctuations during the crystallization of the protein lysozym, we have developed a numerical model that combines diffusion in the bulk of a solution with diffusive transport to microscopic growth steps that propagate on a finite crystal facet. Nonlinearities in layer growth kinetics arising from step interaction by bulk and surface diffusion, and from step generation by surface nucleation, are taken into account. On evaluation of the model with properties characteristic for the solute transport, and the generation and propagation of steps in the lysozyme system, growth rate fluctuations of the same magnitude and characteristic time, as in the experiments, are obtained. The fluctuation time scale is large compared to that of step generation. Variations of the governing parameters of the model reveal that both the nonlinearity in step kinetics and mixed transport-kinetics control of the crystallization process are necessary conditions for the fluctuations. On a microscopic scale, the fluctuations are associated with a morphological instability of the vicinal face, in which a step bunch triggers a cascade of new step bunches through the microscopic interfacial supersaturation distribution.
The trajectories of secondary electrons in the scanning electron microscope.
Konvalina, Ivo; Müllerová, Ilona
2006-01-01
Three-dimensional simulations of the trajectories of secondary electrons (SE) in the scanning electron microscope have been performed for plenty of real configurations of the specimen chamber, including all its basic components. The primary purpose was to evaluate the collection efficiency of the Everhart-Thornley detector of SE and to reveal fundamental rules for tailoring the set-ups in which efficient signal acquisition can be expected. Intuitive realizations about the easiness of attracting the SEs towards the biased front grid of the detector have shown themselves likely as false, and all grounded objects in the chamber have been proven to influence the spatial distribution of the signal-extracting field. The role of the magnetic field penetrating from inside the objective lens is shown to play an ambiguous role regarding possible support for the signal collection.
Laser confocal microscope for analysis of 3013 inner container closure weld region
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinez-Rodriguez, M. J.
As part of the protocol to investigate the corrosion in the inner container closure weld region (ICCWR) a laser confocal microscope (LCM) was used to perform close visual examination of the surface and measurements of corrosion features on the surface. However, initial analysis of selected destructively evaluated (DE) containers using the LCM revealed several challenges for acquiring, processing and interpreting the data. These challenges include topography of the ICCWR sample, surface features, and the amount of surface area for collecting data at high magnification conditions. In FY17, the LCM parameters were investigated to identify the appropriate parameter values for datamore » acquisition and identification of regions of interest. Using these parameter values, selected DE containers were analyzed to determine the extent of the ICCWR to be examined.« less
Mohamed, Amr M; Abdel-Rady, Ahmed; Ahmed, Laila S; El-Hosary, Amira
2012-05-25
The aim of the present study was to evaluate the validity of Theileria annulata surface protein (TaSP)-ELISA, in comparison with traditional microscopic test, for the diagnosis of T. annulata infection among Egyptian baladi cattle (Bos taurus) and water buffaloes (Bubalus bubalis). Molecular confirmation of infection using T. annulata merozoite surface (Tams-1) target amplification by PCR was used as a gold standard. A total of 76 clinically suspected animals including 64 baladi cattle and 12 water buffaloes were investigated in the current study by the three methods. Based on the PCR-confirmed results, the evaluation study revealed higher sensitivity of TaSP-ELISA (72.9% and 75%) as compared to microscopic examination (58.3% and 50%) among cattle and buffaloes, respectively. On the other hand, the specificity of TaSP-ELISA in diagnosis of T. annulata infection was higher (87.5%) in baladi cattle as compared to water buffaloes (37.5%). In conclusion, TaSP-ELISA was shown to be suitable for the diagnosis of T. annulata infection in cattle under field conditions. Copyright © 2011 Elsevier B.V. All rights reserved.
Sensarn, Steven; Zavaleta, Cristina L; Segal, Ehud; Rogalla, Stephan; Lee, Wansik; Gambhir, Sanjiv S; Bogyo, Matthew; Contag, Christopher H
2016-12-01
Early and effective detection of cancers of the gastrointestinal tract will require novel molecular probes and advances in instrumentation that can reveal functional changes in dysplastic and malignant tissues. Here, we describe adaptation of a wide-field clinical fiberscope to perform wide-field fluorescence imaging while preserving its white-light capability for the purpose of providing wide-field fluorescence imaging capability to point-of-care microscopes. We developed and used a fluorescent fiberscope to detect signals from a quenched probe, BMV109, that becomes fluorescent when cleaved by, and covalently bound to, active cathepsin proteases. Cathepsins are expressed in inflammation- and tumor-associated macrophages as well as directly from tumor cells and are a promising target for cancer imaging. The fiberscope has a 1-mm outer diameter enabling validation via endoscopic exams in mice, and therefore we evaluated topically applied BMV109 for the ability to detect colon polyps in an azoxymethane-induced colon tumor model in mice. This wide-field endoscopic imaging device revealed consistent and clear fluorescence signals from BMV109 that specifically localized to the polypoid regions as opposed to the normal adjacent colon tissue (p < 0.004) in the murine colon carcinoma model. The sensitivity of detection of BMV109 with the fluorescence fiberscope suggested utility of these tools for early detection at hard-to-reach sites. The fiberscope was designed to be used in conjunction with miniature, endoscope-compatible fluorescence microscopes for dual wide-field and microscopic cancer detection.
Paknazhad, Niloofar; Mowlavi, Gholamreza; Dupouy Camet, Jean; Jelodar, Mohammad Esmaeili; Mobedi, Iraj; Makki, Mahsasadat; Kia, Eshrat Beigom; Rezaeian, Mostafa; Mohebali, Mehdi; Sarlak, Siamak; Najafi, Faezeh
2016-01-22
The Molavi street archeological site south of Tehran accidentally provided a unique opportunity for paleoparasitological studies in Iran. A female skeleton was unearthed and evaluated to be 7000 years old. Soil samples were collected around the pelvic and sacrum bones. Careful microscopic investigation of rehydrated soil samples revealed the presence of one Enterobius vermicularis egg attached to the skeleton sacral region. The present finding likely represents the oldest evidence of a human pinworm infection in Asia.
Zhang, Ding; Wang, Huai-Ji; Cui, Xiu-Ming; Wang, Cheng-Xiao
2017-06-01
In this work, imidazolium ionic liquids (imidazolium ILs) were employed as the novel chemical permeation enhancers (CPEs) and their performances and mechanisms of action were deeply investigated. Testosterone was used as a model drug to investigate the transdermal delivery enhancement of twenty imdidazolium ILs. The results suggested that the promotion activity connected to the structure and composition of the ILs. The quantitative structure-activity relationship (QSAR) model revealed a good linearity between the electronic properties of ILs and their enhancements. Furthermore, the transepidermal water loss (TEWL) and scanning laser confocal microscope (CLSM) examinations showed the strong improvement of ILs on skin barrier permeability, which were well correlated with the drug penetration profiles. The total reflection-Fourier transform infrared spectroscopy (ATR-FTIR) and atomic force microscope (AFM) evaluations of skins indicated that the ILs can disrupt the regular and compact arrangements of the corneocytes, change the surface properties of stratum corneum, and make the skin structure more permeable. Our work demonstrated the significant skin permeation promotion profiles of the imidazolium ILs, which are of great potential in transdermal drug delivery systems.
Kuijpers, D I M; Hillen, F; Frank, J A
2006-08-01
A 24-year-old female working in the Department of Pathology of a University Hospital developed an acute peri-ocular eczema clearly being related to her daily work at the microscope. Patch testing revealed delayed type hypersensitivity against the black rubber mix, N-isopropyl-N'-phenyl paraphenylenediamine, N-cyclohexyl-N'-phenyl paraphenylenediamine and the rubber ring situated on the ocular of the respective microscope. This is the first report, to our knowledge, on peri-orbital allergic contact eczema because of sensitization with rubber components of a microscope.
Al-Maghrabi, Jaudah Ahmed; Khabaz, Mohamad Nidal
2017-09-04
The World Health Organization has recognized Xp11.2 translocation-associated renal cell carcinoma (RCC) as a distinct neoplasm that arises within the kidney. Although many reports of extrarenal carcinoma may be found in the literature, to the best of our knowledge, Xp11 translocation-associated RCC with intact kidneys has not been documented. This report describes a multilobulated right retroperitoneal soft tissue mass (7.9×5.3×12.6 cm) of a 37-year-old man complaining of abdominal pain in the right side. The patient underwent a computed tomography-guided biopsy. Microscopic evaluation reveals a tumor with papillary and sheaths architectures with cells revealing clear to eosinophilic cytoplasm. Immunohistochemical evaluation on the biopsy reveals that the tumor is positive for PAX-8, CD10, and TFE3. It is negative for CK7, EMA, Vimentin, RCC, CK8/18, D20, CD3, PLAP, OCT4, CD30, MART-1, Inhibin, S-100, HMB-45, Desmin, SMA, and DOG-1. The diagnosis was malignant epithelioid neoplasm and the diagnosis of translocation RCC was suggested. Excision was recommended. The patient underwent right radical nephrectomy with removal of this large mass. Pathologic examination showed a large cystic and solid, nonhomogenous mass with some necrotic areas, originating from the perirenal fat between the adrenal gland and the kidney. Microscopic features showed a tumor with papillary, rhabdoid, and clear cell features. Immunohistochemical stains showed that the tumor cells positively expressed AMACR, PAX-8, CD10, RCC, and TFE3, but were negative for cytokeratins, vimentin, HMB-45, desmin, SMA, EMA, and MSA. Cytogenetic studies confirmed the diagnosis of Xp11.2 translocation-associated RCC with positive TFE3 gene rearrangement. To the best of our knowledge, this type of extrarenal tumor has never been reported.
NASA Astrophysics Data System (ADS)
Manigandan, K.; Srivatsan, T. S.
2015-06-01
In this paper, the results of an experimental study that focused on evaluating the conjoint influence of microstructure and test specimen orientation on fully reversed strain-controlled fatigue behavior of the high alloy steel X2M are presented and discussed. The cyclic stress response of this high-strength alloy steel revealed initial hardening during the first few cycles followed by gradual softening for most of fatigue life. Cyclic strain resistance exhibited a linear trend for the variation of elastic strain amplitude with reversals to failure, and plastic strain amplitude with reversals to failure. Fracture morphology was the same at the macroscopic level over the entire range of cyclic strain amplitudes examined. However, at the fine microscopic level, the alloy steel revealed fracture to be essentially ductile with features reminiscent of predominantly "locally" ductile and isolated brittle mechanisms. The mechanisms governing stress response at the fine microscopic level, fatigue life, and final fracture behavior are presented and discussed in light of the mutually interactive influences of intrinsic microstructural effects, deformation characteristics of the microstructural constituents during fully reversed strain cycling, cyclic strain amplitude, and resultant response stress.
Hot-stage microscopy for determination of API fragmentation: comparison with other methods.
Šimek, Michal; Grünwaldová, Veronika; Kratochvíl, Bohumil
2016-08-01
Although the fragmentation of the active pharmaceutical ingredient (API) is a phenomenon that is mentioned in many literature sources, no well-suited analytical tools for its investigation are currently known. We used the hot-stage microscopy method, already presented in our previous work, and studied the real fragmentation of the tadalafil particles in model tablets which were prepared under different compaction pressures. The morphology, spectral imaging and evaluation of plastic and elastic energies were also analyzed to support the hot-stage method. The prepared blend of tadalafil and excipients was compacted under a several forces from 5 to 35 kN to reveal the trend of fragmentation. The exact fragmentation of tadalafil with increased compaction pressure was revealed by the hot-stage microscopic method and it was in good agreement with plastic and elastic energies. Conversely, spectral imaging, which is being used for this analysis, was considered to be inaccurate methodology as mainly agglomerates, not individual particles, were measured. The availability of the hot-stage microscopic method equips pharmaceutical scientists with an in vitro assessment technique that will more reliably determine the fragmentation of the API in finished tablets and the behavior of the particles when compacted.
A scoring scheme for evaluating magnetofossil identifications
NASA Astrophysics Data System (ADS)
Kopp, R. E.; Kirschvink, J. L.
2007-12-01
In many Quaternary lacustrine and marine settings, fossil magnetotactic bacteria are a major contributor to sedimentary magnetization [1]. Magnetite particles produced by magnetotactic bacteria have traits, shaped by natural selection, that increase the efficiency with which the bacteria utilize iron and also facilitate the recognition of the particles' biological origin. In particular, magnetotactic bacteria generally produce particles with characteristic shapes and narrow size and shape distributions that lie within the single domain stability field. The particles have effective positive magnetic anisotropy, produced by alignment in chains and frequently by particle elongation. In addition, the crystals are often nearly stochiometric and have few crystallographic defects. Yet, despite these distinctive traits, there are few identified magnetofossils that predate the Quaternary, and many putative identifications are highly controversial. We propose a six-criteria scoring scheme for evaluating identifications based on the quality of the geological, magnetic, and electron microscopic evidence. Our criteria are: (1) whether the geological context is well-constrained stratigraphically, and whether paleomagnetic evidence suggests a primary magnetization; (2) whether magnetic or microscopic evidence support the presence of significant single-domain magnetite; (3) whether magnetic or ferromagnetic resonance evidence indicates narrow size and shape distributions, and whether microscopic evidence reveals single-domain particles with truncated edges, elongate single-domain particles, and/or narrow size and shape distributions; (4) whether ferromagnetic resonance, low-temperature magnetic, or electron microscopic evidence reveals the presence of chains; (5) whether low-temperature magnetometry, energy dispersive X-ray spectroscopy, or other techniques demonstrate the near-stochiometry of the particles; and (6) whether high-resolution TEM indicates the near- absence of crystallographic defects. We use criterion 1 to set the threshold for determining whether a magnetofossil identification is robust. Criteria 3 and 4 are assigned numerical scores that range from 0 to 4, while criteria 2, 5, and 6 are evaluated based on presence or absence. Based on this scheme, the oldest robust magnetofossils yet found come from the Cretaceous chalk beds of southern England [2], though Lower Cambrian limestones of the Pestrotsvet Formation, Siberia Platform, only marginally fail to meet our robust criteria [3]. Although magnetofossils have also been reported from Proterozoic, Archean, and Martian rocks, none of these identifications are robust. References: [1] R. E. Kopp and J. L. Kirschvink (2007). Earth Sci. Rev. doi:10.1016/j.earscirev.2007.08.001. [2] P. Montgomery et al. (1998). Earth Planet. Sci. Lett. 156: 209-224. [3] S. B. R. Chang et al. (1987). Phys. Earth Planet. Int. 46: 289-303.
Salakij, Chaleow; Salakij, Jarernsak; Apibal, Suntaree; Narkkong, Nual-Anong; Chanhome, Lawan; Rochanapat, Nirachara
2002-01-01
King cobras (Ophiophagus hannah) have been captive-bred at Queen Saovabha Memorial Institute since 1996 to supply venom for antivenom production. Hematologic tests would be useful for evaluating the health of the snakes, however, basic hematologic data and morphology have not been described for this species. The purpose of this study was to determine basic hematologic values and evaluate light microscopic, cytochemical, and electron microscopic characteristics of king cobra blood cells. Blood samples from 13 wild-caught and 15 captive-bred king cobras were collected into EDTA from the ventral caudal vein. A CBC was done using standard methods. Significant differences between groups were determined using t-tests. Cytochemical stains (periodic acid-Schiff [PAS], Sudan black B [SBB], alpha-naphthyl acetate esterase [ANAE], acid phosphatase [AcP], and beta-glucuronidase [beta-glu]), and scanning and transmission electron microscopy were done using standard techniques. Eighteen snakes (64.3%) were positive for Hepatozoon infection. Hepatozoon organisms were detected nearly twice as frequently in wild-caught (11/13) as in captive-bred (7/15) snakes. Total WBC, azurophil, and lymphocyte counts were higher and fibrinogen concentration was lower in Hepatozoon-positive snakes. Captive-bred snakes had higher RBC values, lower azurophil, heterophil, and punctate reticulocyte percentages, and higher lymphocyte numbers compared with wild-caught snakes. Lymphocytes were the most commonly observed WBCs, and stained positive with PAS, ANAE, AcP, and beta-glu. Azurophil granules stained positive with SBB, PAS, and ANAE. Heterophils were the largest WBCs; their granules stained with SBB, ANAE, and beta-glu. Basophil granules stained with PAS, SBB, ANAE, and beta-glu. Thrombocytes were strongly positive with PAS. Transmission electron microscopic examination revealed organelles within all WBCs except eosinophils and revealed the gamonts of Hepatozoon sp in RBCs and azurophils. These results provide comparative hematologic data and a guide for identification of blood cells in wild-caught and captive-bred king cobra snakes. Hepatozoon infection was relatively common, but was not associated with severe hematologic abnormalities.
Ray, Robin; Barañano, David E; Fortun, Jorge A; Schwent, Bryan J; Cribbs, Blaine E; Bergstrom, Chris S; Hubbard, G Baker; Srivastava, Sunil K
2011-11-01
To evaluate the use of microscope mounted spectral domain optical coherence tomography (SD-OCT) to detect changes in retinal anatomy during macular surgery. Retrospective, observational case series. We included 25 eyes of 24 consecutive patients who underwent SD-OCT during macular surgery. A retrospective review of operative techniques, outcomes, and imaging for all patients who underwent intraoperative microscope mounted SD-OCT during surgery for macular hole or epiretinal membrane (ERM) from April 2009 to April 2010 was performed. Qualitative and quantitative characteristics of intraoperative and postoperative changes in retinal anatomy were studied. Intraoperative change in macular hole dimensions and retinal thickness in patients with ERM owing to surgical manipulation measured using SD-OCT. Intraoperative SD-OCT from 13 eyes of 13 patients undergoing surgery for macular hole was reviewed. Two cases had images of suboptimal quality and were excluded. The remaining 11 eyes were subjected to quantitative analysis, which revealed stability of macular hole height and central hole diameter after internal limiting membrane (ILM) peeling, but an increase in the diameter of subretinal fluid under the macula in ten of 11 eyes (average 87% wider). Intraoperative imaging from 12 eyes of 11 patients undergoing surgery for ERM was analyzed. Quantitative analysis revealed an average increase of retinal thickness after ILM peel of <2%. Ten of 12 eyes developed a new subretinal hyporeflectance, which likely represents shallow detachment of the macula, after uncomplicated membrane peel. Use of intraoperative SD-OCT has provided new insight into the changes to retinal anatomy during macular surgery and may prove to be a useful tool for vitreoretinal surgery. Further study is warranted to determine whether intraoperative changes such as the creation of shallow retinal detachments during uncomplicated macular surgery affects visual recovery. Proprietary or commercial disclosure may be found after the references. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Optical coherence tomography (OCT) of a murine model of chronic kidney disease
NASA Astrophysics Data System (ADS)
Wang, Hsing-Wen; Guo, Hengchang; Andrews, Peter M.; Anderson, Erik; Chen, Y.
2015-03-01
Chronic Kidney Disease (CKD) is characterized by a progressive loss in renal function over time. Pathology can provide valuable insights into the progression of CKD by analyzing the status of glomeruli and the uriniferous tubules over time. Optical coherence tomography (OCT) is a new procedure that can analyze the microscopic structure of the kidney in a non-invasive manner. This is especially important because there are significant artifacts associated with excision biopsies and immersion fixation procedures. Recently, we have shown that OCT can provide real time images of kidney microstructure and Doppler OCT (DOCT) can image glomerular renal blood flow in vivo without administrating exogenous contrast agents. In this study, we used OCT to evaluate CKD in a model induced by intravenous Adriamycin injection into Munich-Wistar rats. We evaluated tubular density and tubular diameter from OCT images at several post- Adriamycin induction time points and compared them with conventional light microscopic histological imaging. Proteinurea and serum creatinine were used as physiological markers of the extent of CKD. Preliminary OCT results revealed changes in tubular density due to tubular necrosis and interstitial fibrosis within the first 4 weeks following Adriamycin injection. From week 4 to 8 after Adriamycin induction, changes in tubular density and diameter occurred due to both tubular loss and tubular dilation. The results suggest OCT can provide additional information about kidney histopathology in CKD. DOCT revealed reduced blood flow in some glomeruli probably as a consequence of focal glomerularsclerosis.
Formative Assessment Probes: Representing Microscopic Life
ERIC Educational Resources Information Center
Keeley, Page
2011-01-01
This column focuses on promoting learning through assessment. The author discusses the formative assessment probe "Pond Water," which reveals how elementary children will often apply what they know about animal structures to newly discovered microscopic organisms, connecting their knowledge of the familiar to the unfamiliar through…
Brilhante, Raimunda Sâmia Nogueira; Correia, Edmilson Emanuel Monteiro; Guedes, Glaucia Morgana de Melo; Pereira, Vandbergue Santos; Oliveira, Jonathas Sales de; Bandeira, Silviane Praciano; Alencar, Lucas Pereira de; Andrade, Ana Raquel Colares de; Castelo-Branco, Débora de Souza Collares Maia; Cordeiro, Rossana de Aguiar; Pinheiro, Adriana de Queiroz; Chaves, Lúcio Jackson Queiroz; Pereira Neto, Waldemiro de Aquino; Sidrim, José Júlio Costa; Rocha, Marcos Fábio Gadelha
2017-07-01
The aim of this study was to evaluate the in vitro and ex vivo biofilm-forming ability of dermatophytes on a nail fragment. Initially, four isolates of Trichophyton rubrum, six of Trichophyton tonsurans, three of Trichophyton mentagrophytes, ten of Microsporum canis and three of Microsporum gypseum were tested for production biomass by crystal violet assay. Then, one strain per species presenting the best biofilm production was chosen for further studies by optical microscopy (Congo red staining), confocal laser scanning (LIVE/DEAD staining) and scanning electron (secondary electron) microscopy. Biomass quantification by crystal violet assay, optical microscope images of Congo red staining, confocal microscope and scanning electron microscope images revealed that all species studied are able to form biofilms both in vitro and ex vivo, with variable density and architecture. M. gypseum, T. rubrum and T. tonsurans produced robust biofilms, with abundant matrix and biomass, while M. canis produced the weakest biofilms compared to other species. This study sheds light on biofilms of different dermatophyte species, which will contribute to a better understanding of the pathophysiology of dermatophytosis. Further studies of this type are necessary to investigate the processes involved in the formation and composition of dermatophyte biofilms.
Jolliff, B.; Knoll, A.; Morris, R.V.; Moersch, J.; McSween, H.; Gilmore, M.; Arvidson, R.; Greeley, R.; Herkenhoff, K.; Squyres, S.
2002-01-01
Blind field tests of the Field Integration Design and Operations (FIDO) prototype Mars rover were carried out 7-16 May 2000. A Core Operations Team (COT), sequestered at the Jet Propulsion Laboratory without knowledge of test site location, prepared command sequences and interpreted data acquired by the rover. Instrument sensors included a stereo panoramic camera, navigational and hazard-avoidance cameras, a color microscopic imager, an infrared point spectrometer, and a rock coring drill. The COT designed command sequences, which were relayed by satellite uplink to the rover, and evaluated instrument data. Using aerial photos and Airborne Visible and Infrared Imaging Spectrometer (AVIRIS) data, and information from the rover sensors, the COT inferred the geology of the landing site during the 18 sol mission, including lithologic diversity, stratigraphic relationships, environments of deposition, and weathering characteristics. Prominent lithologic units were interpreted to be dolomite-bearing rocks, kaolinite-bearing altered felsic volcanic materials, and basalt. The color panoramic camera revealed sedimentary layering and rock textures, and geologic relationships seen in rock exposures. The infrared point spectrometer permitted identification of prominent carbonate and kaolinite spectral features and permitted correlations to outcrops that could not be reached by the rover. The color microscopic imager revealed fine-scale rock textures, soil components, and results of coring experiments. Test results show that close-up interrogation of rocks is essential to investigations of geologic environments and that observations must include scales ranging from individual boulders and outcrops (microscopic, macroscopic) to orbital remote sensing, with sufficient intermediate steps (descent images) to connect in situ and remote observations.
Sensarn, Steven; Zavaleta, Cristina L.; Segal, Ehud; Rogalla, Stephan; Lee, Wansik; Gambhir, Sanjiv S.; Bogyo, Matthew; Contag, Christopher H.
2017-01-01
Purpose Early and effective detection of cancers of the gastrointestinal tract will require novel molecular probes and advances in instrumentation that can reveal functional changes in dysplastic and malignant tissues. Here, we describe adaptation of a wide-field clinical fiberscope to perform wide-field fluorescence imaging while preserving its white-light capability for the purpose of providing wide-field fluorescence imaging capability to point-of-care microscopes. Procedures We developed and used a fluorescent fiberscope to detect signals from a quenched probe, BMV109, that becomes fluorescent when cleaved by, and covalently bound to, active cathepsin proteases. Cathepsins are expressed in inflammation- and tumor-associated macrophages as well as directly from tumor cells and are a promising target for cancer imaging. The fiberscope has a 1-mm outer diameter enabling validation via endoscopic exams in mice, and therefore we evaluated topically applied BMV109 for the ability to detect colon polyps in an azoxymethane-induced colon tumor model in mice. Results This wide-field endoscopic imaging device revealed consistent and clear fluorescence signals from BMV109 that specifically localized to the polypoid regions as opposed to the normal adjacent colon tissue (p < 0.004) in the murine colon carcinoma model. Conclusions The sensitivity of detection of BMV109 with the fluorescence fiberscope suggested utility of these tools for early detection at hard-to-reach sites. The fiberscope was designed to be used in conjunction with miniature, endoscope-compatible fluorescence microscopes for dual wide-field and microscopic cancer detection. PMID:27154508
Spectral confocal reflection microscopy using a white light source
NASA Astrophysics Data System (ADS)
Booth, M.; Juškaitis, R.; Wilson, T.
2008-08-01
We present a reflection confocal microscope incorporating a white light supercontinuum source and spectral detection. The microscope provides images resolved spatially in three-dimensions, in addition to spectral resolution covering the wavelength range 450-650nm. Images and reflection spectra of artificial and natural specimens are presented, showing features that are not normally revealed in conventional microscopes or confocal microscopes using discrete line lasers. The specimens include thin film structures on semiconductor chips, iridescent structures in Papilio blumei butterfly scales, nacre from abalone shells and opal gemstones. Quantitative size and refractive index measurements of transparent beads are derived from spectral interference bands.
Abdulkader, Marwah M; Yousef, Mohammad M; Abdelhadi, Mohamad K; Amr, Samir S; Alabsi, Eyad S; Al-Abbadi, Mousa A
2013-05-01
We present a 27-yr-old female with gonadal dysgenesis (46, XY), who presented to our hospital with poor consciousness, aphasia, restlessness, and visual hallucination. Physical examination revealed normal breast development and normal external female genetalia. Computed tomography scan of the head and neck revealed the presence of brain edema, hydrocephalous, and a localized hypodense lesion in the hypothalamus. Her serum was positive for the anti-Ma2, which is associated with paraneoplastic encephalitis syndrome. Computed tomography of the abdomen revealed the presence of a 7.5×5.3×3.0 cm solid pelvic mass. Interestingly, a single microscopic focus of dysgerminoma was identified in a background of stromal fibrosis and focal dystrophic calcifications. No ovarian stroma or testicular tissue was identified. To our knowledge, this is the first case of gonadal dysgenesis presenting with anti-Ma2 paraneoplastic encephalitis with dysgerminoma. A discussion about paraneoplastic encephalitis with a microscopic dysgerminoma associated with anti-Ma2 antibody is presented.
Performance evaluation of image segmentation algorithms on microscopic image data.
Beneš, Miroslav; Zitová, Barbara
2015-01-01
In our paper, we present a performance evaluation of image segmentation algorithms on microscopic image data. In spite of the existence of many algorithms for image data partitioning, there is no universal and 'the best' method yet. Moreover, images of microscopic samples can be of various character and quality which can negatively influence the performance of image segmentation algorithms. Thus, the issue of selecting suitable method for a given set of image data is of big interest. We carried out a large number of experiments with a variety of segmentation methods to evaluate the behaviour of individual approaches on the testing set of microscopic images (cross-section images taken in three different modalities from the field of art restoration). The segmentation results were assessed by several indices used for measuring the output quality of image segmentation algorithms. In the end, the benefit of segmentation combination approach is studied and applicability of achieved results on another representatives of microscopic data category - biological samples - is shown. © 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.
1978-01-01
The assertion that ingestion of human erythrocytes is restricted to invasive strains of Entamoeba histolytica has not been evaluated previously by comparative studies. In this report we describe the in vitro ingestion of human erythrocytes by pathogenic and nonpathogenic Entamoeba. Microscopic evaluation of erythrophagocytosis by eight different Entamoeba grown in culture revealed that strains of E. histolytica isolated from cases of human dysentery show a much higher rate of erythrocyte ingestion than nonpathogenic strains. However, all strains are able to phagocytize erythrocytes. The extremely high rate of phagocytic activity shown by pathogenic E. histolytica could be one of the properties related to the pathogenicity of this parasitic protozoan. PMID:722237
Sticktight fleas associated with fowl pox in a backyard chicken flock in California.
Gustafson, C R; Bickford, A A; Cooper, G L; Charlton, B R
1997-01-01
A mixed breed rooster, from a backyard flock of 13 chickens, was received at California Veterinary Diagnostic Laboratory System-Turlock Branch for postmortem examination. The bird presented with thickened, featherless, scab-encrusted skin around the head region. Numerous sticktight fleas were found attached to the encrusted skin. Microscopic evaluation of the skin revealed a lymphoplasmacytic reaction in the dermis with visible embedded flea mouthparts. Also noted histologically in this region were epidermal hyperplasia and ballooned epidermal cells containing intracytoplasmic inclusions indicative of fowl poxvirus.
Randell, Rebecca; Ruddle, Roy A; Mello-Thoms, Claudia; Thomas, Rhys G; Quirke, Phil; Treanor, Darren
2013-01-01
To create and evaluate a virtual reality (VR) microscope that is as efficient as the conventional microscope, seeking to support the introduction of digital slides into routine practice. A VR microscope was designed and implemented by combining ultra-high-resolution displays with VR technology, techniques for fast interaction, and high usability. It was evaluated using a mixed factorial experimental design with technology and task as within-participant variables and grade of histopathologist as a between-participant variable. Time to diagnosis was similar for the conventional and VR microscopes. However, there was a significant difference in the mean magnification used between the two technologies, with participants working at a higher level of magnification on the VR microscope. The results suggest that, with the right technology, efficient use of digital pathology for routine practice is a realistic possibility. Further work is required to explore what magnification is required on the VR microscope for histopathologists to identify diagnostic features, and the effect on this of the digital slide production process. © 2012 Blackwell Publishing Limited.
Current Approach to the Evaluation and Management of Microscopic Colitis.
Cotter, Thomas G; Pardi, Darrell S
2017-02-01
Microscopic colitis is a common cause of chronic watery diarrhea, particularly in the elderly. The accompanying symptoms, which include abdominal pain and fatigue, can markedly impair patients' quality of life. Diagnosis is based upon characteristic histologic findings of the colonic mucosa. This review focuses on the current approach to evaluation and management of patients with microscopic colitis. Although the incidence of microscopic colitis has been increasing over time, recent epidemiological studies show stabilization at 21.0-24.7 cases per 100,000 person-years. Recent research has further expanded our knowledge of the underlying pathophysiology and emphasized the entity of drug-induced microscopic colitis and the association with celiac disease. Two recent randomized studies have confirmed the effectiveness of oral budesonide for both induction and maintenance treatment of microscopic colitis and is now endorsed by the American Gastroenterological Association as first-line treatment. The incidence of microscopic colitis has stabilized at just over 20 cases per 100,000 person-years. Celiac disease and drug-induced microscopic colitis should be considered in all patients diagnosed with microscopic colitis. There are a number of treatments available for patients with microscopic colitis; however, budesonide is the only option well studied in controlled trials and is effective for both induction and maintenance treatment.
The impact of loupes and microscopes on vision in endodontics.
Perrin, P; Neuhaus, K W; Lussi, A
2014-05-01
To report on an intraradicular visual test in a simulated clinical setting under different optical conditions. Miniaturized visual tests with E-optotypes (bar distance from 0.01 to 0.05 mm) were fixed inside the root canal system of an extracted maxillary molar at different locations: at the orifice, a depth of 5 mm and the apex. The tooth was mounted in a phantom head for a simulated clinical setting. Unaided vision was compared with Galilean loupes (2.5× magnification) with integrated light source and an operating microscope (6× magnification). The influence of the dentists' age within two groups was evaluated: <40 years (n = 9) and ≥40 years (n = 15). Some younger dentists were able to identify the E-optotypes at the orifice, but otherwise, natural vision did not reveal any measurable result. With Galilean loupes, the younger dentists <40 years could see a 0.05 mm structure at the root canal orifice, in contrast to the older group ≥40 years. Only the microscope allowed the observation of structures inside the root canal, independent of age. Unaided vision and Galilean loupes with an integrated light source could not provide any measurable vision inside the root canal, but younger dentists <40 years could detect with Galilean loupes a canal orifice corresponding to the tip of the smallest endodontic instruments. Dentists over 40 years of age were dependent on the microscope to inspect the root canal system. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Neodymium:yttrium-aluminum-garnet laser fusion of endarterectomy flaps.
Humphrey, P W; Slocum, M M; Loy, T S; Silver, D
1995-07-01
This study evaluated the efficacy of neodymium:yttrium-aluminum-garnet laser welding of flaps in canine arteries and in securing the distal flap during human carotid endarterectomy. Endarterectomy flaps were created in both common carotid and both common femoral arteries in 12 dogs. The flaps were repaired with either the neodymium:yttrium-aluminum-garnet laser or with 6-0 polypropylene sutures. The arteries were removed after duplex scanning at either 7 or 28 days. Eighteen high carotid endarterectomy flaps in 16 patients have been subsequently secured with the laser welding technique. Laser repairs (125 +/- 19 joule) of the canine arteries were completed more quickly than suture repairs (mean 25 seconds vs 135 seconds, respectively; p < 0.04). Duplex ultrasonography revealed no discernable differences between the two groups of arteries. Arteries studied at 7 days revealed three microscopic flaps (two suture, one laser), more subintimal fibroblastic proliferation in suture than laser-repaired carotid arteries (3: 1, p = 0.0530), and similar amounts of inflammation in suture- and laser-repaired arteries. Arteries studied at 28 days revealed one microscopic intimal flap (suture-repaired); equal fibroblastic and inflammatory responses in suture- and laser-repaired vessels; and no evidence of laser thermal injury. Eighteen carotid endarterectomy flaps have been successfully fused with no immediate or long-term complications in 16 patients (follow-up of 0 to 24 months). Laser fusion appears to be a safe and effective method for securing distal carotid endarterectomy flaps.
de Carvalhosa, Artur Aburad; de Araújo Estrela, Cyntia Rodrigues; Borges, Alvaro Henrique; Guedes, Orlando Aguirre; Estrela, Carlos
2014-10-01
Radiographic images may lead to misinterpretations of lesions of endodontic and nonendodontic origin. This report describes a case of a 10-year follow-up of a calcifying odontogenic cyst (COC) in the periapical region of a vital maxillary central incisor in a 9-year-old boy. The patient revealed a history of a swelling in the periapical area of tooth #9. The patient denied any dental trauma or history of pain. Clinical examination revealed no mobility, but there was discrete discomfort when horizontal pressure was applied. Pulp vitality was present in all maxillary anterior teeth. Radiographs revealed an oval radiolucent lesion in the periapical region of maxillary central incisor. The therapeutic option was enucleation of the periapical lesion and histologic examination of the specimen. Microscopic findings suggested the diagnosis of a COC. At a follow-up visit 10 years after surgery, panoramic and periapical radiographs showed new bone formation; the patient did not have any pain, and pulp vitality was maintained in all teeth in this area. A COC should be part of the differential diagnosis of other jaw lesions, such as apical periodontitis. The definitive diagnosis of a COC can only be made after microscopic evaluation of the specimen. The follow-up is a helpful reference because it confirms the survival of pulp tissue and no recurrence of the COC. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Wilberts, B L; Arruda, P H; Kinyon, J M; Madson, D M; Frana, T S; Burrough, E R
2014-11-01
Swine dysentery is classically associated with infection by Brachyspira hyodysenteriae, the only current officially recognized Brachyspira sp. that consistently imparts strong beta-hemolysis on blood agar. Recently, several strongly beta-hemolytic Brachyspira have been isolated from swine with clinical dysentery that are not identified as B. hyodysenteriae by PCR including the recently proposed species "Brachyspira hampsonii." In this study, 6-week-old pigs were inoculated with either a clinical isolate of "B. hampsonii" (EB107; n = 10) clade II or a classic strain of B. hyodysenteriae (B204; n = 10) to compare gross and microscopic lesions and alterations in colonic mucin expression in pigs with clinical disease versus controls (n = 6). Gross lesions were similar between infected groups. No histologic difference was observed between infected groups with regard to neutrophilic inflammation, colonic crypt depth, mucosal ulceration, or hemorrhage. Histochemical and immunohistochemical evaluation of the apex of the spiral colon revealed decreased expression of sulphated mucins, decreased expression of MUC4, and increased expression of MUC5AC in diseased pigs compared to controls. No difference was observed between diseased pigs in inoculated groups. This study reveals significant alterations in colonic mucin expression in pigs with acute swine dysentery and further reveals that these and other microscopic changes are similar following infection with "B. hampsonii" clade II or B. hyodysenteriae. © The Author(s) 2014.
EVALUATION OF CONFOCAL MICROSCOPY SYSTEM PERFORMANCE
BACKGROUND. The confocal laser scanning microscope (CLSM) has enormous potential in many biological fields. Currently there is a subjective nature in the assessment of a confocal microscope's performance by primarily evaluating the system with a specific test slide provided by ea...
Scanning tunneling microscopy and atomic force microscopy: application to biology and technology.
Hansma, P K; Elings, V B; Marti, O; Bracker, C E
1988-10-14
The scanning tunneling microscope (STM) and the atomic force microscope (AFM) are scanning probe microscopes capable of resolving surface detail down to the atomic level. The potential of these microscopes for revealing subtle details of structure is illustrated by atomic resolution images including graphite, an organic conductor, an insulating layered compound, and individual adsorbed oxygen atoms on a semiconductor. Application of the STM for imaging biological materials directly has been hampered by the poor electron conductivity of most biological samples. The use of thin conductive metal coatings and replicas has made it possible to image some biological samples, as indicated by recently obtained images of a recA-DNA complex, a phospholipid bilayer, and an enzyme crystal. The potential of the AFM, which does not require a conductive sample, is shown with molecular resolution images of a nonconducting organic monolayer and an amino acid crystal that reveals individual methyl groups on the ends of the amino acids. Applications of these new microscopes to technology are demonstrated with images of an optical disk stamper, a diffraction grating, a thin-film magnetic recording head, and a diamond cutting tool. The STM has even been used to improve the quality of diffraction gratings and magnetic recording heads.
Szleszkowski, Ł; Hałoń, A; Thannhäuser, A; Jurek, T
2015-01-01
Assessment of the usefulness of intravital lesions in the proximal attachment of the sternocleidomastoid muscle and the mastoid process of the temporal bone in medico-legal evaluation of death by hanging. The study material was obtained from the bodies of 35 people who died by hanging. The control group comprised specimens collected from 30 people who died of non-traumatic causes. The structures under study were examined macro- and microscopically. The basic change which could be recognized as a marker of intravitality of hanging was the presence of a macroscopically extensive blotchy area of abundant ecchymosis in the proximal muscle attachment, similar to that found in the distal attachment, and the presence of abundant diffuse intraosseous ecchymoses in the mastoid process. None of the cases revealed any ecchymoses in the proximal attachment of the muscle that would be similar to those present in the distal attachment. Discolourations within the mastoid processes, macroscopically suggestive of extensive intraosseous effusions arising from the mechanism of stretching, were not confirmed by microscopic evaluation and occurred at the same frequency as in the control group. Limitations of the study were related to the method which involved sample collection by means of bone chisels, decalcification and preparation of specimens, which had an effect, for example, on the measurable evaluation of the degree of congestion. The study has failed to provide convincing and unambiguous data on the usefulness of examining mastoid processes and proximal attachments of the sternocleidomastoid muscles during autopsy to determine the presence of intravitality features of hanging. A description of research methodology and its associated difficulties, e.g. with the interpretation of results, can also be useful for the planning of similar studies by other researchers.
Evaluation of a completely robotized neurosurgical operating microscope.
Kantelhardt, Sven R; Finke, Markus; Schweikard, Achim; Giese, Alf
2013-01-01
Operating microscopes are essential for most neurosurgical procedures. Modern robot-assisted controls offer new possibilities, combining the advantages of conventional and automated systems. We evaluated the prototype of a completely robotized operating microscope with an integrated optical coherence tomography module. A standard operating microscope was fitted with motors and control instruments, with the manual control mode and balance preserved. In the robot mode, the microscope was steered by a remote control that could be fixed to a surgical instrument. External encoders and accelerometers tracked microscope movements. The microscope was additionally fitted with an optical coherence tomography-scanning module. The robotized microscope was tested on model systems. It could be freely positioned, without forcing the surgeon to take the hands from the instruments or avert the eyes from the oculars. Positioning error was about 1 mm, and vibration faded in 1 second. Tracking of microscope movements, combined with an autofocus function, allowed determination of the focus position within the 3-dimensional space. This constituted a second loop of navigation independent from conventional infrared reflector-based techniques. In the robot mode, automated optical coherence tomography scanning of large surface areas was feasible. The prototype of a robotized optical coherence tomography-integrated operating microscope combines the advantages of a conventional manually controlled operating microscope with a remote-controlled positioning aid and a self-navigating microscope system that performs automated positioning tasks such as surface scans. This demonstrates that, in the future, operating microscopes may be used to acquire intraoperative spatial data, volume changes, and structural data of brain or brain tumor tissue.
Woess, Claudia; Unterberger, Seraphin Hubert; Roider, Clemens; Ritsch-Marte, Monika; Pemberger, Nadin; Cemper-Kiesslich, Jan; Hatzer-Grubwieser, Petra; Parson, Walther; Pallua, Johannes Dominikus
2017-01-01
Due to the influence of many environmental processes, a precise determination of the post-mortem interval (PMI) of skeletal remains is known to be very complicated. Although methods for the investigation of the PMI exist, there still remains much room for improvement. In this study the applicability of infrared (IR) microscopic imaging techniques such as reflection-, ATR- and Raman- microscopic imaging for the estimation of the PMI of human skeletal remains was tested. PMI specific features were identified and visualized by overlaying IR imaging data with morphological tissue structures obtained using light microscopy to differentiate between forensic and archaeological bone samples. ATR and reflection spectra revealed that a more prominent peak at 1042 cm-1 (an indicator for bone mineralization) was observable in archeological bone material when compared with forensic samples. Moreover, in the case of the archaeological bone material, a reduction in the levels of phospholipids, proteins, nucleic acid sugars, complex carbohydrates as well as amorphous or fully hydrated sugars was detectable at (reciprocal wavelengths/energies) between 3000 cm-1 to 2800 cm-1. Raman spectra illustrated a similar picture with less ν2PO43-at 450 cm-1 and ν4PO43- from 590 cm-1 to 584 cm-1, amide III at 1272 cm-1 and protein CH2 deformation at 1446 cm-1 in archeological bone material/samples/sources. A semi-quantitative determination of various distributions of biomolecules by chemi-maps of reflection- and ATR- methods revealed that there were less carbohydrates and complex carbohydrates as well as amorphous or fully hydrated sugars in archaeological samples compared with forensic bone samples. Raman- microscopic imaging data showed a reduction in B-type carbonate and protein α-helices after a PMI of 3 years. The calculated mineral content ratio and the organic to mineral ratio displayed that the mineral content ratio increases, while the organic to mineral ratio decreases with time. Cluster-analyses of data from Raman microscopic imaging reconstructed histo-anatomical features in comparison to the light microscopic image and finally, by application of principal component analyses (PCA), it was possible to see a clear distinction between forensic and archaeological bone samples. Hence, the spectral characterization of inorganic and organic compounds by the afore mentioned techniques, followed by analyses such as multivariate imaging analysis (MIAs) and principal component analyses (PCA), appear to be suitable for the post mortem interval (PMI) estimation of human skeletal remains.
Roider, Clemens; Ritsch-Marte, Monika; Pemberger, Nadin; Cemper-Kiesslich, Jan; Hatzer-Grubwieser, Petra; Parson, Walther; Pallua, Johannes Dominikus
2017-01-01
Due to the influence of many environmental processes, a precise determination of the post-mortem interval (PMI) of skeletal remains is known to be very complicated. Although methods for the investigation of the PMI exist, there still remains much room for improvement. In this study the applicability of infrared (IR) microscopic imaging techniques such as reflection-, ATR- and Raman- microscopic imaging for the estimation of the PMI of human skeletal remains was tested. PMI specific features were identified and visualized by overlaying IR imaging data with morphological tissue structures obtained using light microscopy to differentiate between forensic and archaeological bone samples. ATR and reflection spectra revealed that a more prominent peak at 1042 cm-1 (an indicator for bone mineralization) was observable in archeological bone material when compared with forensic samples. Moreover, in the case of the archaeological bone material, a reduction in the levels of phospholipids, proteins, nucleic acid sugars, complex carbohydrates as well as amorphous or fully hydrated sugars was detectable at (reciprocal wavelengths/energies) between 3000 cm-1 to 2800 cm-1. Raman spectra illustrated a similar picture with less ν2PO43−at 450 cm-1 and ν4PO43− from 590 cm-1 to 584 cm-1, amide III at 1272 cm-1 and protein CH2 deformation at 1446 cm-1 in archeological bone material/samples/sources. A semi-quantitative determination of various distributions of biomolecules by chemi-maps of reflection- and ATR- methods revealed that there were less carbohydrates and complex carbohydrates as well as amorphous or fully hydrated sugars in archaeological samples compared with forensic bone samples. Raman- microscopic imaging data showed a reduction in B-type carbonate and protein α-helices after a PMI of 3 years. The calculated mineral content ratio and the organic to mineral ratio displayed that the mineral content ratio increases, while the organic to mineral ratio decreases with time. Cluster-analyses of data from Raman microscopic imaging reconstructed histo-anatomical features in comparison to the light microscopic image and finally, by application of principal component analyses (PCA), it was possible to see a clear distinction between forensic and archaeological bone samples. Hence, the spectral characterization of inorganic and organic compounds by the afore mentioned techniques, followed by analyses such as multivariate imaging analysis (MIAs) and principal component analyses (PCA), appear to be suitable for the post mortem interval (PMI) estimation of human skeletal remains. PMID:28334006
Aqeel, Yousuf; Siddiqui, Ruqaiyyah; Ateeq, Muhammad; Raza Shah, Muhammad; Kulsoom, Huma; Khan, Naveed Ahmed
2015-01-01
Light microscopy and electron microscopy have been successfully used in the study of microbes, as well as free-living protists. Unlike light microscopy, which enables us to observe living organisms or the electron microscope which provides a two-dimensional image, atomic force microscopy provides a three-dimensional surface profile. Here, we observed two free-living amoebae, Acanthamoeba castellanii and Balamuthia mandrillaris under the phase contrast inverted microscope, transmission electron microscope and atomic force microscope. Although light microscopy was of lower magnification, it revealed functional biology of live amoebae such as motility and osmoregulation using contractile vacuoles of the trophozoite stage, but it is of limited value in defining the cyst stage. In contrast, transmission electron microscopy showed significantly greater magnification and resolution to reveal the ultra-structural features of trophozoites and cysts including intracellular organelles and cyst wall characteristics but it only produced a snapshot in time of a dead amoeba cell. Atomic force microscopy produced three-dimensional images providing detailed topographic description of shape and surface, phase imaging measuring boundary stiffness, and amplitude measurements including width, height and length of A. castellanii and B. mandrillaris trophozoites and cysts. These results demonstrate the importance of the application of various microscopic methods in the biological and structural characterization of the whole cell, ultra-structural features, as well as surface components and cytoskeleton of protist pathogens. © 2014 The Author(s) Journal of Eukaryotic Microbiology © 2014 International Society of Protistologists.
DOT National Transportation Integrated Search
2003-01-01
This study evaluated existing traffic signal optimization programs including Synchro,TRANSYT-7F, and genetic algorithm optimization using real-world data collected in Virginia. As a first step, a microscopic simulation model, VISSIM, was extensively ...
NASA Astrophysics Data System (ADS)
Zhou, Jialing; He, Honghui; Wang, Ye; Ma, Hui
2017-02-01
Fiber structure changes in the various pathological processes, such as the increase of fibrosis in liver diseases, the derangement of fiber in cervical cancer and so on. Currently, clinical pathologic diagnosis is regarded as the golden criterion, but different doctors with discrepancy in knowledge and experience may obtain different conclusions. Up to a point, quantitative evaluation of the fiber structure in the pathological tissue can be of great service to quantitative diagnosis. Mueller matrix measurement is capable of probing comprehensive microstructural information of samples and different wavelength of lights can provide more information. In this paper, we use a Mueller matrix microscope with light sources in six different wavelength. We use unstained, dewaxing liver tissue slices in four stages and the pathological biopsy of the filtration channels from rabbit eyes as samples. We apply the Mueller matrix polar decomposition (MMPD) parameter δ which corresponds to retardance to liver slices. The mean value of abnormal region get bigger when the level of fibrosis get higher and light in short wavelength is more sensitive to the microstructure of fiber. On the other hand, we use the Mueller matrix transformation (MMT) parameter Φ which is associated to the angel of fast axis in the analysis of the slices of the filtration channels from rabbit eyes. The value of kurtosis and the value of skewness shows big difference between new born region and normal region and can reveal the arrangement of fiber. These results indicate that the Mueller matrix microscope has great potential in auxiliary diagnosis.
NASA Astrophysics Data System (ADS)
Loukanov, Alexandre; Filipov, Chavdar; Valcheva, Violeta; Lecheva, Marta; Emin, Saim
2015-04-01
The semiconductor zinc oxide nanomaterial (ZnO or ZnO:H) is widely used in advanced biosensor technology for the design of highly-sensitive detector elements for various applications. In the attempt to evaluate its effect on common microorganisms, two types of nanostructured transducer films have been used (average diameter 600-1000 nm). They have been prepared by using both wet sol-gel method and magnetron sputtering. Their polycrystalline structure and specific surface features have been analyzed by X-ray diffraction (XRD), scanning electron microscope, and atomic force microscope. The assessment of growth stimulation of bacteria was determined using epifluorescent microscope by cell staining with Live/Dead BacLight kit. In our experiments, the growth stimulation of Gram-positive and Gram-negative bacteria on nanostructured ZnO film is demonstrated by Bacillus cereus and Pseudomonas putida. These two bacterial species have been selected, because they are well known and studied in biosensor technologies, with structural difference of their cell walls. These pathogens are easy for with common source in the liquid food or some commercial products. Our data has revealed that the method of transducer film preparation influences strongly bacterial inhibition and division. These results present the transforming signal precisely, when ZnO is used in biosensor applications.
High-speed vibrational imaging and spectral analysis of lipid bodies by compound Raman microscopy.
Slipchenko, Mikhail N; Le, Thuc T; Chen, Hongtao; Cheng, Ji-Xin
2009-05-28
Cells store excess energy in the form of cytoplasmic lipid droplets. At present, it is unclear how different types of fatty acids contribute to the formation of lipid droplets. We describe a compound Raman microscope capable of both high-speed chemical imaging and quantitative spectral analysis on the same platform. We used a picosecond laser source to perform coherent Raman scattering imaging of a biological sample and confocal Raman spectral analysis at points of interest. The potential of the compound Raman microscope was evaluated on lipid bodies of cultured cells and live animals. Our data indicate that the in vivo fat contains much more unsaturated fatty acids (FAs) than the fat formed via de novo synthesis in 3T3-L1 cells. Furthermore, in vivo analysis of subcutaneous adipocytes and glands revealed a dramatic difference not only in the unsaturation level but also in the thermodynamic state of FAs inside their lipid bodies. Additionally, the compound Raman microscope allows tracking of the cellular uptake of a specific fatty acid and its abundance in nascent cytoplasmic lipid droplets. The high-speed vibrational imaging and spectral analysis capability renders compound Raman microscopy an indispensible analytical tool for the study of lipid-droplet biology.
Kransdorf, Evan P; Fishbein, Mike C; Czer, Lawrence S C; Patel, Jignesh K; Velleca, Angela; Tazelaar, Henry D; Roy, R Raina; Steidley, D Eric; Kobashigawa, Jon A; Luthringer, Daniel J
2016-08-01
The pathologic features of chronic Chagas cardiomyopathy may not be widely appreciated in the United States. We sought to describe the gross, microscopic, immunohistochemical, and molecular pathology features useful to diagnose chronic Chagas cardiomyopathy. The features from a case series of cardiectomy specimens of patients undergoing heart transplantation (12 patients) or mechanical circulatory support device implantation (one patient) for chronic Chagas cardiomyopathy at three institutions in the United States are reported and analyzed. Gross findings included enlarged and dilated ventricles (100% of cases), mural thrombi (54%), epicardial plaques (42%), and left ventricular aneurysm (36%). Microscopic evaluation revealed myocarditis (100% of cases) characterized by mononuclear cell infiltration, fibrosis (100%), nonnecrotizing granulomas (62%), and giant cells (38%). Two specimens (15%) showed rare intracellular amastigotes. Immunohistochemical assays for Trypanosoma cruzi organisms were negative in all cardiectomy specimens, whereas tissue polymerase chain reaction was positive in six (54%) of 11 cases. The gross and microscopic features of chronic Chagas cardiomyopathy in the United States appear similar to those reported in endemic countries. Importantly, tissue polymerase chain reaction may be useful to confirm the diagnosis. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Surface Roughening Behavior of 6063 Aluminum Alloy during Bulging by Spun Tubes
Cai, Yang; Wang, Xiaosong; Yuan, Shijian
2017-01-01
Severe surface roughening during the hydroforming of aluminum alloy parts can produce surface defects that severely restrict their application in the automobile and aerospace industry. To understand the relation between strain, grain size and surface roughness under biaxial stress conditions, hydro-bulging tests of aluminum alloy tubes were carried out, and the tubes with different grain sizes were prepared by a spinning and annealing process. The surface roughness was measured by a laser scanning confocal microscope to evaluate the surface roughening macroscopical behavior, and the corresponding microstructures were observed using electron back-scattered diffraction (EBSD) to reveal the roughening microscopic behavior. The results obtained show that the surface roughness increased with both strain and grain size under biaxial stress. No surface defects were observed on the surface when the grain size was less than 105 μm if the strain was less than 18%, or when the grain size was between 130 and 175 μm if the strain was less than 15.88% and 7.15%, respectively. The surface roughening microscopic behavior was identified as an inhomogeneous grain size distribution, which became more pronounced with increasing grain size and resulted in greater local deformation. Concentrated grain orientation also results in severe inhomogeneous deformation during plastics deformation, and serious surface roughening. PMID:28772658
Smartphone confocal microscopy for imaging cellular structures in human skin in vivo.
Freeman, Esther E; Semeere, Aggrey; Osman, Hany; Peterson, Gary; Rajadhyaksha, Milind; González, Salvador; Martin, Jeffery N; Anderson, R Rox; Tearney, Guillermo J; Kang, Dongkyun
2018-04-01
We report development of a low-cost smartphone confocal microscope and its first demonstration of in vivo human skin imaging. The smartphone confocal microscope uses a slit aperture and diffraction grating to conduct two-dimensional confocal imaging without using any beam scanning devices. Lateral and axial resolutions of the smartphone confocal microscope were measured as 2 and 5 µm, respectively. In vivo confocal images of human skin revealed characteristic cellular structures, including spinous and basal keratinocytes and papillary dermis. Results suggest that the smartphone confocal microscope has a potential to examine cellular details in vivo and may help disease diagnosis in resource-poor settings, where conducting standard histopathologic analysis is challenging.
Smartphone confocal microscopy for imaging cellular structures in human skin in vivo
Freeman, Esther E.; Semeere, Aggrey; Osman, Hany; Peterson, Gary; Rajadhyaksha, Milind; González, Salvador; Martin, Jeffery N.; Anderson, R. Rox; Tearney, Guillermo J.; Kang, Dongkyun
2018-01-01
We report development of a low-cost smartphone confocal microscope and its first demonstration of in vivo human skin imaging. The smartphone confocal microscope uses a slit aperture and diffraction grating to conduct two-dimensional confocal imaging without using any beam scanning devices. Lateral and axial resolutions of the smartphone confocal microscope were measured as 2 and 5 µm, respectively. In vivo confocal images of human skin revealed characteristic cellular structures, including spinous and basal keratinocytes and papillary dermis. Results suggest that the smartphone confocal microscope has a potential to examine cellular details in vivo and may help disease diagnosis in resource-poor settings, where conducting standard histopathologic analysis is challenging. PMID:29675328
Influence of graphene quantum dots on electrical properties of polymer composites
NASA Astrophysics Data System (ADS)
Arthisree, D.; Joshi, Girish M.
2017-07-01
We successfully prepared synthetic nanocomposite (SNC) by dispersing graphene quantum dots (GQD) in cellulose acetate (CA) polymer system. The dispersion and occupied network of GQD were foreseen by microscopic techniques. The variation of plane to crossed linked array network was observed by the polarizing optical microscopic (POM) technique. The scanning electron microscopy (SEM) revealed the leaves like impressions of GQD in host polymer system. The series network of GQD occupied in CA at higher resolution was confirmed by transmission electron microscopy (TEM). The two dimensional (2D) topographic images demonstrated an entangled polymer network to plane morphology. The variation in surface roughness was evaluated from the dimensional (3D) topography. The influence of temperature on AC conductivity with highest value (4 × 10-5 S cm-1), contributes to the decrease in activation energy. The DC conductivity obeys the percolation criteria co-related to the GQD loading by weight fraction. Furthermore, this synthetic nanocomposite is feasible for the development of sensing and electrical applications.
The relation of apple texture with cell wall nanostructure studied using an atomic force microscope.
Cybulska, Justyna; Zdunek, Artur; Psonka-Antonczyk, Katarzyna M; Stokke, Bjørn T
2013-01-30
In this study, the relation of the nanostructure of cell walls with their texture was investigated for six different apple cultivars. Cell wall material (CWM) and cellulose microfibrils were imaged by atomic force microscope (AFM). The mean diameter of cellulose microfibrils for each cultivar was estimated based on the AFM height topographs obtained using the tapping mode of dried specimens. Additionally, crystallinity of cellulose microfibrils and pectin content was determined. Texture of apple cultivars was evaluated by sensory and instrumental analysis. Differences in cellulose diameter as determined from the AFM height topographs of the nanostructure of cell walls of the apple cultivars are found to relate to the degree of crystallinity and pectin content. Cultivars with thicker cellulose microfibrils also revealed crisper, harder and juicier texture, and greater acoustic emission. The data suggest that microfibril thickness affects the mechanical strength of cell walls which has consequences for sensory and instrumental texture. Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Zhian; Yang, Xing; Fu, Yun; Du, Ke
2015-11-01
Ultrathin molybdenum diselenide nanosheets are decorated on the surface of multi-walled carbon nanotubes (MWCNT) via a one-step hydrothermal method. Uniform MoSe2 nanosheets are firmly anchored on MWCNT according to the characterizations of scanning electron microscope (SEM), transmission electron microscope (TEM). When evaluated as anodes for sodium storage, the MoSe2@MWCNT composites deliver a reversible specific capacity of 459 mAh g-1 at a current of 200 mA g-1 over 90 cycles, and a specific capacity of 385 mAh g-1 even at a current rate of 2000 mAh g-1, which is better than the MoSe2 nanosheets. The enhanced electrochemical performance of the MoSe2@MWCNT composites can be ascribed to the synergic effects of MoSe2 nanosheets and MWCNT. The high capacity and good rate performance reveal that the MoSe2@MWCNT composites are very promising for applications in sodium-ion batteries.
Iwasaki, S; Asami, T; Wanichanon, C
1996-04-01
Various species of turtles are adapted to different environments, such as freshwater, seawater, and terrestrial habitats. Comparisons of histological and ultrastructural features of the tongue of the juvenile Hawksbill turtle, Eretmochelys imbricata bissa, with those of freshwater turtles should reveal some aspects of the relationship between the structure of the lingual epithelium and the environment. The light microscope, scanning electron microscope and transmission electron microscope were used. Light microscopy revealed that the mucosal epithelium of the tongue was of the keratinized, stratified squamous type. Under the scanning electron microscope, no lingual papillae were visible on the dorsal surface of the tongue. Micropits and the thickening of cell margins were clearly seen on the surface of cells located on the outermost side. The transmission electron microscope revealed that the cells in the intermediate layer were gradually flattened from the basal side to the surface side, as were their nuclei. In the shallow intermediate layer, the cells were significantly flattened, and their nuclei were condensed or had disappeared. The cytoplasm contained keratohyalin granules, tonofibrils, free ribosomes, mitochondria, and rough endoplasmic reticulum. Numerous free ribosomes were attached to the surface of small keratohyalin granules. The cells of the keratinized layer were significantly flattened, and their nuclei had completely disappeared. Most of cytoplasm was filled with keratin fibers of high electron density. Keratin fibers of the shedding cells, which were located on the outermost side of the keratinized layer, appeared looser, and each fiber, which was somewhat thicker than the tonofibrils and tonofilaments, was clearly distinguishable. The lingual epithelium of the juvenile Hawksbill turtle differs significantly from that of the adult freshwater turtle, in spite of the similarity in gross morphology of the tongues of these species.
Yokota, Yasuyuki; Miyamoto, Hiroo; Imanishi, Akihito; Takeya, Jun; Inagaki, Kouji; Morikawa, Yoshitada; Fukui, Ken-Ichi
2018-05-09
Electric double-layer transistors based on ionic liquid/organic semiconductor interfaces have been extensively studied during the past decade because of their high carrier densities at low operation voltages. Microscopic structures and the dynamics of ionic liquids likely determine the device performance; however, knowledge of these is limited by a lack of appropriate experimental tools. In this study, we investigated ionic liquid/organic semiconductor interfaces using molecular dynamics to reveal the microscopic properties of ionic liquids. The organic semiconductors include pentacene, rubrene, fullerene, and 7,7,8,8-tetracyanoquinodimethane (TCNQ). While ionic liquids close to the substrate always form the specific layered structures, the surface properties of organic semiconductors drastically alter the ionic dynamics. Ionic liquids at the fullerene interface behave as a two-dimensional ionic crystal because of the energy gain derived from the favorable electrostatic interaction on the corrugated periodic substrate.
Kamonwanon, Pranithida; Yodmongkol, Sirasa; Chantarachindawong, Rojcharin; Thaweeboon, Sroisiri; Thaweeboon, Boonyanit; Srikhirin, Toemsak
2015-08-01
Wear resistance is a limitation of artificial denture teeth. Improving the wear resistance of conventional artificial denture teeth is of value to prosthodontic patients. The purpose of this in vitro study was to evaluate the wear resistance and hardness of modified polymethyl methacrylate artificial denture teeth compared to 5 commercially available artificial tooth materials. This study evaluated 180 artificial denture teeth (6 groups) that included 3 groups of conventional artificial teeth (MajorDent, Cosmo HXL, and Gnathostar), 2 groups of composite resin artificial teeth (Endura and SR Orthosit PE), and 1 group of modified surface artificial teeth. The flattened buccal surface of each tooth (n=15) was prepared for investigation with the Vickers hardness test and the elucidate wear test (n=15) by using a brushing machine. Each group was loaded for 18,000 cycles, at 2 N, and 150 rpm. The wear value was identified with a profilometer. The data were statistically analyzed by using 1-way ANOVA and post hoc Turkey honestly significant difference tests (α=.001). The tribologies were observed under a scanning electron microscope, and the cytotoxicities were evaluated by MTT assay. The Vickers hardnesses ranged from 28.48 to 39.36. The wear depths and worn surface area values ranged from 1.12 to 10.79 μm and from 6.74 to 161.95 μm(2). The data revealed that the modified artificial denture teeth were significantly harder and exhibited significantly higher wear resistance than did the conventional artificial teeth (P<.001). The scanning electron microscopic images revealed cross sections of the conventional artificial denture teeth with intensively worn surface areas after brushing. The cytotoxicity test revealed 97.85% cell viability, which indicates the nontoxicity of the modified surface of this material. Within the limitations of this study, the polymethyl methacrylate modified surface artificial denture teeth was not significantly different from that of the composite resin artificial denture teeth, with the exceptions that the surface was harder and more wear resistant. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Shapira, Adi; Konopnicki, Muriel; Hammad-Saied, Mohammed; Shabad, Evelyn
2014-07-01
Pearson disease is a rare, usually fatal, mitochondrial disorder affecting primarily the bone marrow and the exocrine pancreas. We report a previously healthy 10-week-old girl who presented with profound macrocytic anemia followed by pancytopenia, synthetic liver dysfunction with liver steatosis, and metabolic acidosis with high lactate levels. She had no pancreatic involvement. Multiple cytoplasmic vacuoles in myelocytes and monocytes were seen upon microscopic evaluation of the bone marrow. Genetic analysis of the mitochondrial genome revealed a 5 kbp deletion, thus establishing the diagnosis of Pearson disease.
Visonà, S D; Chen, Y; Bernardi, P; Andrello, L; Osculati, A
2018-03-01
Deaths from electricity, generally, do not have specific findings at the autopsy. The diagnosis is commonly based on the circumstances of the death and the morphologic findings, above all the current mark. Yet, the skin injury due to an electrocution and other kinds of thermal injuries often cannot be differentiated with certainty. Therefore, there is a great interest in finding specific markers of electrocution. The search for the metallization of the skin through Scanning Electron Microscope equipped with Energy Dispersive X-Ray Spectroscopy (EDS) probe is of special importance in order to achieve a definite diagnosis in case of suspected electrocution. We selected five cases in which the electrocution was extremely likely considering the circumstances of the death. In each case a forensic autopsy was performed. Then, the skin specimens were stained with Hematoxylin Eosin and Perls. On the other hand, the skin lesions were examined with a scanning electron microscope equipped with EDS probe in order to evaluate the morphological ultrastructural features and the presence of deposits on the surface of the skin. The typical skin injury of the electrocution (current mark) were macroscopically detected in all of the cases. The microscopic examination of the skin lesions revealed the typical spherical vacuoles in the horny layer and, in the epidermis, the elongation of the cell nuclei as well as necrosis. Perls staining was negative in 4 out 6 cases. Ultrastructural morphology revealed the evident vacuolization of the horny layer, elongation of epidermic cells, coagulation of the elastic fibers. In the specimens collected from the site of contact with the conductor of case 1 and 2, the presence of the Kα peaks of iron was detected. In the corresponding specimens taken from cases 2, 4, 5 the microanalysis showed the Kα peaks of titanium. In case 3, titanium and carbon were found. In the suspicion of electrocution, the integrated use of different tools is recommended, including macroscopic observation, H&E staining, iron-specific staining, scanning electron microscopy and EDS microanalysis. Only the careful interpretation of the results provided by all these methods can allow the pathologist to correctly identify the cause of the death. Particularly, the present study suggests that the microanalysis (SEM-EDS) represents a very useful tool for the diagnosis of electrocution, allowing the detection and the identification of the metals embedded in the skin and their evaluation in the context of the ultrastructural morphology. Copyright © 2018. Published by Elsevier B.V.
Evaluation and purchase of confocal microscopes: Numerous factors to consider
The purchase of a confocal microscope can be a complex and difficult decision for an individual scientist, group or evaluation committee. This is true even for scientists that have used confocal technology for many years. The task of reaching the optimal decision becomes almost i...
Stewart, Sherry M; Dowers, Kristy L; Cerda, Jacey R; Schoenfeld-Tacher, Regina M; Kogan, Lori R
2014-01-01
Microscopy (skill of using a microscope) and the concepts of cytology (study of cells) and histology (study of tissues) are most often taught in professional veterinary medicine programs through the traditional method of glass slides and light microscopes. Several limiting factors in veterinary training programs are encouraging educators to explore innovative options for teaching microscopy skills and the concepts of cytology and histology. An anonymous online survey was administered through the Colorado Veterinary Medical Association to Colorado veterinarians working in private practice. It was designed to assess their current usage of microscopes for cytological and histological evaluation of specimens and their perceptions of microscope use in their veterinary education. The first part of the survey was answered by 183 veterinarians, with 104 indicating they had an onsite diagnostic lab. Analysis pertaining to the use of the microscope in practice and in veterinary programs was conducted on this subset. Most respondents felt the amount of time spent in the curriculum using a microscope was just right for basic microscope use and using the microscope for viewing and learning about normal and abnormal histological sections and clinical cytology. Participants felt more emphasis could be placed on clinical and diagnostic cytology. Study results suggest that practicing veterinarians frequently use microscopes for a wide variety of cytological diagnostics. However, only two respondents indicated they prepared samples for histological evaluation. Veterinary schools should consider these results against the backdrop of pressure to implement innovative teaching techniques to meet the changing needs of the profession.
A Novel Hyperspectral Microscopic Imaging System for Evaluating Fresh Degree of Pork.
Xu, Yi; Chen, Quansheng; Liu, Yan; Sun, Xin; Huang, Qiping; Ouyang, Qin; Zhao, Jiewen
2018-04-01
This study proposed a rapid microscopic examination method for pork freshness evaluation by using the self-assembled hyperspectral microscopic imaging (HMI) system with the help of feature extraction algorithm and pattern recognition methods. Pork samples were stored for different days ranging from 0 to 5 days and the freshness of samples was divided into three levels which were determined by total volatile basic nitrogen (TVB-N) content. Meanwhile, hyperspectral microscopic images of samples were acquired by HMI system and processed by the following steps for the further analysis. Firstly, characteristic hyperspectral microscopic images were extracted by using principal component analysis (PCA) and then texture features were selected based on the gray level co-occurrence matrix (GLCM). Next, features data were reduced dimensionality by fisher discriminant analysis (FDA) for further building classification model. Finally, compared with linear discriminant analysis (LDA) model and support vector machine (SVM) model, good back propagation artificial neural network (BP-ANN) model obtained the best freshness classification with a 100 % accuracy rating based on the extracted data. The results confirm that the fabricated HMI system combined with multivariate algorithms has ability to evaluate the fresh degree of pork accurately in the microscopic level, which plays an important role in animal food quality control.
A Novel Hyperspectral Microscopic Imaging System for Evaluating Fresh Degree of Pork
Xu, Yi; Chen, Quansheng; Liu, Yan; Sun, Xin; Huang, Qiping; Ouyang, Qin; Zhao, Jiewen
2018-01-01
Abstract This study proposed a rapid microscopic examination method for pork freshness evaluation by using the self-assembled hyperspectral microscopic imaging (HMI) system with the help of feature extraction algorithm and pattern recognition methods. Pork samples were stored for different days ranging from 0 to 5 days and the freshness of samples was divided into three levels which were determined by total volatile basic nitrogen (TVB-N) content. Meanwhile, hyperspectral microscopic images of samples were acquired by HMI system and processed by the following steps for the further analysis. Firstly, characteristic hyperspectral microscopic images were extracted by using principal component analysis (PCA) and then texture features were selected based on the gray level co-occurrence matrix (GLCM). Next, features data were reduced dimensionality by fisher discriminant analysis (FDA) for further building classification model. Finally, compared with linear discriminant analysis (LDA) model and support vector machine (SVM) model, good back propagation artificial neural network (BP-ANN) model obtained the best freshness classification with a 100 % accuracy rating based on the extracted data. The results confirm that the fabricated HMI system combined with multivariate algorithms has ability to evaluate the fresh degree of pork accurately in the microscopic level, which plays an important role in animal food quality control. PMID:29805285
Wide-field computational imaging of pathology slides using lens-free on-chip microscopy.
Greenbaum, Alon; Zhang, Yibo; Feizi, Alborz; Chung, Ping-Luen; Luo, Wei; Kandukuri, Shivani R; Ozcan, Aydogan
2014-12-17
Optical examination of microscale features in pathology slides is one of the gold standards to diagnose disease. However, the use of conventional light microscopes is partially limited owing to their relatively high cost, bulkiness of lens-based optics, small field of view (FOV), and requirements for lateral scanning and three-dimensional (3D) focus adjustment. We illustrate the performance of a computational lens-free, holographic on-chip microscope that uses the transport-of-intensity equation, multi-height iterative phase retrieval, and rotational field transformations to perform wide-FOV imaging of pathology samples with comparable image quality to a traditional transmission lens-based microscope. The holographically reconstructed image can be digitally focused at any depth within the object FOV (after image capture) without the need for mechanical focus adjustment and is also digitally corrected for artifacts arising from uncontrolled tilting and height variations between the sample and sensor planes. Using this lens-free on-chip microscope, we successfully imaged invasive carcinoma cells within human breast sections, Papanicolaou smears revealing a high-grade squamous intraepithelial lesion, and sickle cell anemia blood smears over a FOV of 20.5 mm(2). The resulting wide-field lens-free images had sufficient image resolution and contrast for clinical evaluation, as demonstrated by a pathologist's blinded diagnosis of breast cancer tissue samples, achieving an overall accuracy of ~99%. By providing high-resolution images of large-area pathology samples with 3D digital focus adjustment, lens-free on-chip microscopy can be useful in resource-limited and point-of-care settings. Copyright © 2014, American Association for the Advancement of Science.
Utility and safety of a novel surgical microscope laser light source
Bakhit, Mudathir S.; Suzuki, Kyouichi; Sakuma, Jun; Fujii, Masazumi; Murakami, Yuta; Ito, Yuhei; Sugano, Tetsuo; Saito, Kiyoshi
2018-01-01
Objective Tissue injuries caused by the thermal effects of xenon light microscopes have previously been reported. Due to this, the development of a safe microscope light source became a necessity. A newly developed laser light source is evaluated regarding its effectiveness and safety as an alternative to conventional xenon light source. Methods We developed and tested a new laser light source for surgical microscopes. Four experiments were conducted to compare xenon and laser lights: 1) visual luminance comparison, 2) luminous and light chromaticity measurements, 3) examination and analysis of visual fatigue, and 4) comparison of focal temperature elevation due to light source illumination using porcine muscle samples. Results Results revealed that the laser light could be used at a lower illumination value than the xenon light (p < 0.01). There was no significant difference in visual fatigue status between the laser light and the xenon light. The laser light was superior to the xenon light regarding luminous intensity and color chromaticity. The focal temperature elevation of the muscle samples was significantly higher when irradiated with xenon light in vitro than with laser light (p < 0.01). Conclusion The newly developed laser light source is more efficient and safer than a conventional xenon light source. It lacks harmful ultraviolet waves, has a longer lifespan, a lower focal temperature than that of other light sources, a wide range of brightness and color production, and improved safety for the user’s vision. Further clinical trials are necessary to validate the impact of this new light source on the patient’s outcome and prognosis. PMID:29390016
Hakki, S S; Celenligil-Nazliel, H; Karaduman, A; Usubütün, A; Ertoy, D; Ayhan, A; Ruacan, S
2001-04-01
Epidermolysis bullosa acquisita (EBA) is an uncommon, acquired, chronic subepidermal bullous disease. This report describes a case of EBA with gingival involvement. A 43-year-old woman with EBA was referred to our clinic for periodontal therapy because of gingival tenderness and bleeding. She has been on cyclosporin A therapy for the last 2 years. Clinical findings were analyzed. Anterior gingivectomy operations were performed in 2 stages. The samples obtained during the surgery were examined using histopathologic, immunohistologic, and electronmicroscopic methods. Long-term effects of the surgical periodontal treatment on gingiva were evaluated both clinically and microscopically. The dentition displayed minimal enamel hypoplasia. Decayed, missing, and filled surfaces score was found to be elevated. Periodontal examination showed generalized diffuse gingival inflammation and gingival enlargement localized mainly to the anterior region. Nikolsky's sign was positive. However, wound healing was uneventful after the operations. Microscopic findings were similar to those obtained from the skin. Twenty-one months after the operations, Nikolsky's sign was negative and no remarkable gingival inflammation was noted. Microscopic examination revealed that the blisters were fewer in number and smaller in size. These results indicate that gingival tissues may also be involved in EBA. Uneventful wound healing after periodontal surgery in this case suggests that periodontal surgery can be performed in patients with EBA. Moreover, both our clinical and histopathologic findings imply that gingivectomy proves useful in maintaining gingival integrity in these patients. Our data may also suggest that the patients with EBA are highly likely to develop dental caries.
Scanning electron microscope observation of dislocations in semiconductor and metal materials.
Kuwano, Noriyuki; Itakura, Masaru; Nagatomo, Yoshiyuki; Tachibana, Shigeaki
2010-08-01
Scanning electron microscope (SEM) image contrasts have been investigated for dislocations in semiconductor and metal materials. It is revealed that single dislocations can be observed in a high contrast in SEM images formed by backscattered electrons (BSE) under the condition of a normal configuration of SEM. The BSE images of dislocations were compared with those of the transmission electron microscope and scanning transmission electron microscope (STEM) and the dependence of BSE image contrast on the tilting of specimen was examined to discuss the origin of image contrast. From the experimental results, it is concluded that the BSE images of single dislocations are attributed to the diffraction effect and related with high-angle dark-field images of STEM.
Desai, Darshan B; Aldawsari, Mabkhoot Mudith S; Alharbi, Bandar Mohammed H; Sen, Sanchari; Grave de Peralta, Luis
2015-09-01
We show that various setups for optical microscopy which are commonly used in biomedical laboratories behave like efficient microscope condensers that are responsible for observed subwavelength resolution. We present a series of experiments and simulations that reveal how inclined illumination from such unexpected condensers occurs when the sample is perpendicularly illuminated by a microscope's built-in white-light source. In addition, we demonstrate an inexpensive add-on optical module that serves as an efficient and lightweight microscope condenser. Using such add-on optical module in combination with a low-numerical-aperture objective lens and Fourier plane imaging microscopy technique, we demonstrate detection of photonic crystals with a period nearly eight times smaller than the Rayleigh resolution limit.
Pathologists dislike sound? Evaluation of a computerised training microscope.
Gray, E; Duvall, E; Sprey, J; Bird, C C
1998-01-01
AIM: To evaluate the use of multimedia enhancements, using a computerised microscope, in the training of microscope skills. METHODS: The HOME microscope provides facilities to highlight features of interest in conjunction with either text display or aural presentation. A pilot study was carried out with 10 individuals, eight of whom were at different stages of pathology training. A tutorial was implemented employing sound or text, and each individual tested each version. Both the subjective impressions of users and objective measurement of their patterns of use were recorded. RESULTS: Although both versions improved learning, users took longer to work through the aural than the text version; 90% of users preferred the text only version, including all eight individuals involved in pathology training. CONCLUSIONS: Pathologists appear to prefer visual rather than aural input when using teaching systems such as the HOME microscope and sound does not give added value to the training experience. Images PMID:9659250
Evaluation environment for digital and analog pathology: a platform for validation studies
Gallas, Brandon D.; Gavrielides, Marios A.; Conway, Catherine M.; Ivansky, Adam; Keay, Tyler C.; Cheng, Wei-Chung; Hipp, Jason; Hewitt, Stephen M.
2014-01-01
Abstract. We present a platform for designing and executing studies that compare pathologists interpreting histopathology of whole slide images (WSIs) on a computer display to pathologists interpreting glass slides on an optical microscope. eeDAP is an evaluation environment for digital and analog pathology. The key element in eeDAP is the registration of the WSI to the glass slide. Registration is accomplished through computer control of the microscope stage and a camera mounted on the microscope that acquires real-time images of the microscope field of view (FOV). Registration allows for the evaluation of the same regions of interest (ROIs) in both domains. This can reduce or eliminate disagreements that arise from pathologists interpreting different areas and focuses on the comparison of image quality. We reduced the pathologist interpretation area from an entire glass slide (10 to 30 mm2) to small ROIs (<50 μm2). We also made possible the evaluation of individual cells. We summarize eeDAP’s software and hardware and provide calculations and corresponding images of the microscope FOV and the ROIs extracted from the WSIs. The eeDAP software can be downloaded from the Google code website (project: eeDAP) as a MATLAB source or as a precompiled stand-alone license-free application. PMID:26158076
Evaluation environment for digital and analog pathology: a platform for validation studies.
Gallas, Brandon D; Gavrielides, Marios A; Conway, Catherine M; Ivansky, Adam; Keay, Tyler C; Cheng, Wei-Chung; Hipp, Jason; Hewitt, Stephen M
2014-10-01
We present a platform for designing and executing studies that compare pathologists interpreting histopathology of whole slide images (WSIs) on a computer display to pathologists interpreting glass slides on an optical microscope. eeDAP is an evaluation environment for digital and analog pathology. The key element in eeDAP is the registration of the WSI to the glass slide. Registration is accomplished through computer control of the microscope stage and a camera mounted on the microscope that acquires real-time images of the microscope field of view (FOV). Registration allows for the evaluation of the same regions of interest (ROIs) in both domains. This can reduce or eliminate disagreements that arise from pathologists interpreting different areas and focuses on the comparison of image quality. We reduced the pathologist interpretation area from an entire glass slide (10 to [Formula: see text]) to small ROIs ([Formula: see text]). We also made possible the evaluation of individual cells. We summarize eeDAP's software and hardware and provide calculations and corresponding images of the microscope FOV and the ROIs extracted from the WSIs. The eeDAP software can be downloaded from the Google code website (project: eeDAP) as a MATLAB source or as a precompiled stand-alone license-free application.
Particle nonuniformity effects on particle cloud flames in low gravity
NASA Technical Reports Server (NTRS)
Berlad, A. L.; Tangirala, V.; Seshadri, K.; Facca, L. T.; Ogrin, J.; Ross, H.
1991-01-01
Experimental and analytical studies of particle cloud combustion at reduced gravity reveal the substantial roles that particle cloud nonuniformities may play in particle cloud combustion. Macroscopically uniform, quiescent particle cloud systems (at very low gravitational levels and above) sustain processes which can render them nonuniform on both macroscopic and microscopic scales. It is found that a given macroscopically uniform, quiescent particle cloud flame system can display a range of microscopically nonuniform features which lead to a range of combustion features. Microscopically nonuniform particle cloud distributions are difficult experimentally to detect and characterize. A uniformly distributed lycopodium cloud of particle-enriched microscopic nonuniformities in reduced gravity displays a range of burning velocities for any given overall stoichiometry. The range of observed and calculated burning velocities corresponds to the range of particle enriched concentrations within a characteristic microscopic nonuniformity. Sedimentation effects (even in reduced gravity) are also examined.
Day, C L; Harrist, T J; Gorstein, F; Sober, A J; Lew, R A; Friedman, R J; Pasternack, B S; Kopf, A W; Fitzpatrick, T B; Mihm, M C
1981-01-01
A review of the microscope slides of the primary tumors for 596 patients with clinical Stage I melanoma revealed that primary lesions displayed two distinct patterns of invasion: 1) single cell invasion with direct extension of the main body of tumor into the reticular dermis or subcutaneous fat, and 2) invasion with "microscope satellites" (i.e. discrete tumor nests greater than 0.05 mm in diameter, that were separated from the main body of the tumor by normal reticular dermal collagen or subcutaneous fat). The five-year disease free survival rate for 95 patients with "microscopic satellites" was 36% +/- 6%. This is in contrast to a five-year disease free survival rate of 89% +/- 2% for 501 patients without these satellites (p = 4.3 x 10(-29), generalized Wilcoxon test). "Microscopic satellites" (present vs absent) was comparable to histologic ulceration in its additive prognostic effect of tumor thickness (Breslow). PMID:7247529
Cha, Yoon Jin; Nahm, Ji Hae; Ko, Ji Eun; Shin, Hyun Joo; Chang, Jong-Hee; Cho, Nam Hoon
2015-01-01
Purpose We aimed to evaluate the histologic and radiologic findings of vascular lesions after stereotactic radiosurgery (SRS) categorized as radiation-induced cavernous hemangioma (RICH). Materials and Methods Among 89 patients who underwent neurosurgery for cavernous hemangioma, eight RICHs from 7 patients and 10 de novo CHs from 10 patients were selected for histopathological and radiological comparison. Results Histologically, RICHs showed hematoma-like gross appearance. Microscopically, RICH exhibited a hematoma-like area accompanied by proliferation of thin-walled vasculature with fibrin deposits and infiltrating foamy macrophages. In contrast, CHs demonstrated localized malformed vasculature containing fresh and old clotted blood on gross examination. Typically, CHs consisted of thick, ectatic hyalinized vessels lined by endothelium under a light microscope. Magnetic resonance imaging of RICHs revealed some overlapping but distinct features with CHs, including enhancing cystic and solid components with absence or incomplete popcorn-like appearance and partial hemosiderin rims. Conclusion Together with histologic and radiologic findings, RICH may result from blood-filled space after tissue destruction by SRS, accompanied with radiation-induced reactive changes rather than vascular malformation. Thus, the term "RICH" would be inappropriate, because it is more likely to be an inactive organizing hematoma rather than proliferation of malformed vasculature. PMID:26446658
Jain, Gaurav K; Pathan, Shadab A; Akhter, Sohail; Jayabalan, Nirmal; Talegaonkar, Sushma; Khar, Roop K; Ahmad, Farhan J
2011-02-01
The interaction of PLGA-chitosan Nanoplexes with ocular mucosa was investigated ex vivo and in vivo to assess their potential as ocular delivery system. Fluorescent Rhodamine Nanoplexes (Rd-Nanoplexes) were prepared by ionotropic gelation method. The size and morphology of Nanoplexes was investigated by TEM, SEM and PCS. The corneal retention, uptake and penetration of Nanoplexes were analyzed by spectrofluorimetry and confocal microscopy. Corneas from Rd-Nanoplexes-treated rabbits were evaluated for the in vivo uptake and ocular tolerance. The Nanoplexes prepared were round with a mean diameter of 115.6±17nm and the encapsulation efficiency of Rd was 59.4±2.5%. Data from ex vivo and in vivo studies showed that the amounts of Rd in the cornea were significantly higher for Nanoplexes than for a control Rd solution, these amounts being fairly constant for up to 24h. Confocal microscopy of the corneas revealed paracellular and transcellular uptake of the Nanoplexes. The uptake mechanism postulated was adsorptive-mediated endocytosis and opening of the tight junctions between epithelial cells. No alteration was microscopically observed after ocular surface exposure to Nanoplexes. Taken together, these data demonstrate that Nanoplexes are potentially useful as ocular drug carriers. Copyright © 2010 Elsevier B.V. All rights reserved.
Using laser technological unit ALTI "Karavella" for precision components of IEP production
NASA Astrophysics Data System (ADS)
Labin, N. A.; Chursin, A. D.; Paramonov, V. S.; Klimenko, V. I.; Paramonova, G. M.; Kolokolov, I. S.; Vinogradov, K. Y.; Betina, L. L.; Bulychev, N. A.; Dyakov, Yu. A.; Zakharyan, R. A.; Kazaryan, M. A.; Koshelev, K. K.; Kosheleva, O. K.; Grigoryants, A. G.; Shiganov, I. N.; Krasovskii, V. I.; Sachkov, V. I.; Plyaka, P. S.; Feofanov, I. N.; Chen, C.
2015-12-01
The paper revealed the using of industrial production equipment ALTI "Karavella-1", "Karavella-1M", "Karavella-2" and "Karavella-2M" precision components of IEP production [1-4]. The basis for the ALTI using in the IEP have become the positive results of research and development of technologies of foil (0.01-0.2 mm) and thin sheets (0.3-1 mm) materials micromachining by pulsed radiation CVL [5, 6]. To assess the micromachining quality and precision the measuring optical microscope (UHL VMM200), projection microscope (Mitutoyo PV5100) and Carl Zeiss microscope were used.
Real-time terahertz near-field microscope.
Blanchard, F; Doi, A; Tanaka, T; Hirori, H; Tanaka, H; Kadoya, Y; Tanaka, K
2011-04-25
We report a terahertz near-field microscope with a high dynamic range that can capture images of a 370 x 740 μm2 area at 35 frames per second. We achieve high spatial resolution (14 μm corresponding to λ/30 for a center frequency at 0.7 THz) on a large area by combining two novel techniques: terahertz generation by tilted-pulse-front excitation and electro-optic balanced imaging detection using a thin crystal. To demonstrate the microscope capability, we reveal the field enhancement at the gap position of a dipole antenna after the irradiation of a terahertz pulse.
Design and analysis of multilayer x ray/XUV microscope
NASA Technical Reports Server (NTRS)
Shealy, David L.
1990-01-01
The design and analysis of a large number of normal incidence multilayer x ray microscopes based on the spherical mirror Schwarzschild configuration is examined. Design equations for the spherical mirror Schwarzschild microscopes are summarized and used to evaluate mirror parameters for microscopes with magnifications ranging from 2 to 50x. Ray tracing and diffraction analyses are carried out for many microscope configurations to determine image resolution as a function of system parameters. The results are summarized in three publication included herein. A preliminary study of advanced reflecting microscope configurations, where aspherics are used in place of the spherical microscope mirror elements, has indicated that the aspherical elements will improve off-axis image resolution and increase the effective field of view.
Spagnuolo, G; Ametrano, G; D'Antò, V; Rengo, C; Simeone, M; Riccitiello, F; Amato, M
2012-12-01
To evaluate the effects of repeated autoclave sterilization cycles on surface topography of conventional nickel-titanium ( NiTi ) and titanium nitride ( TiN )-coated rotary instruments. A total of 60 NiTi rotary instruments, 30 ProTaper (Dentsply Maillefer) and 30 TiN -coated AlphaKite (Komet/Gebr. Brasseler), were analysed. Instruments were evaluated in the as-received condition and after 1, 5 and 10 sterilization cycles. After sterilization, the samples were observed using scanning electron microscope (SEM), and surface chemical analysis was performed on each instrument with energy dispersive X-ray spectroscopy (EDS). Moreover, the samples were analysed by atomic force microscopy (AFM), and roughness average (Ra) and the root mean square value (RMS) of the scanned surface profiles were recorded. Data were analysed by means of anova followed by Tukey's test. Scanning electron microscope observations revealed the presence of pitting and deep milling marks in all instruments. EDS analysis confirmed that both types of instruments were composed mainly of nickel and titanium, whilst AlphaKite had additional nitride. After multiple autoclave sterilization cycles, SEM examinations revealed an increase in surface alterations, and EDS values indicated changes in chemical surface composition in all instruments. Ra and RMS values of ProTaper significantly increased after 5 (P = 0.006) and 10 cycles (P = 0.002) with respect to the as-received instruments, whilst AlphaKite showed significant differences compared with the controls after 10 cycles (P = 0.03). Multiple autoclave sterilization cycles modified the surface topography and chemical composition of conventional and TiN -coated NiTi rotary instruments. © 2012 International Endodontic Journal.
Acoustic Emission of Deformation Twinning in Magnesium.
Mo, Chengyang; Wisner, Brian; Cabal, Mike; Hazeli, Kavan; Ramesh, K T; El Kadiri, Haitham; Al-Samman, Talal; Molodov, Konstantin D; Molodov, Dmitri A; Kontsos, Antonios
2016-08-06
The Acoustic Emission of deformation twinning in Magnesium is investigated in this article. Single crystal testing with combined full field deformation measurements, as well as polycrystalline testing inside the scanning electron microscope with simultaneous monitoring of texture evolution and twin nucleation were compared to testing at the laboratory scale with respect to recordings of Acoustic Emission activity. Single crystal testing revealed the formation of layered twin boundaries in areas of strain localization which was accompanied by distinct changes in the acoustic data. Testing inside the microscope directly showed twin nucleation, proliferation and growth as well as associated crystallographic reorientations. A post processing approach of the Acoustic Emission activity revealed the existence of a class of signals that appears in a strain range in which twinning is profuse, as validated by the in situ and ex situ microscopy observations. Features extracted from such activity were cross-correlated both with the available mechanical and microscopy data, as well as with the Acoustic Emission activity recorded at the laboratory scale for similarly prepared specimens. The overall approach demonstrates that the method of Acoustic Emission could provide real time volumetric information related to the activation of deformation twinning in Magnesium alloys, in spite of the complexity of the propagation phenomena, the possible activation of several deformation modes and the challenges posed by the sensing approach itself when applied in this type of materials evaluation approach.
Acoustic Emission of Deformation Twinning in Magnesium
Mo, Chengyang; Wisner, Brian; Cabal, Mike; Hazeli, Kavan; Ramesh, K. T.; El Kadiri, Haitham; Al-Samman, Talal; Molodov, Konstantin D.; Molodov, Dmitri A.; Kontsos, Antonios
2016-01-01
The Acoustic Emission of deformation twinning in Magnesium is investigated in this article. Single crystal testing with combined full field deformation measurements, as well as polycrystalline testing inside the scanning electron microscope with simultaneous monitoring of texture evolution and twin nucleation were compared to testing at the laboratory scale with respect to recordings of Acoustic Emission activity. Single crystal testing revealed the formation of layered twin boundaries in areas of strain localization which was accompanied by distinct changes in the acoustic data. Testing inside the microscope directly showed twin nucleation, proliferation and growth as well as associated crystallographic reorientations. A post processing approach of the Acoustic Emission activity revealed the existence of a class of signals that appears in a strain range in which twinning is profuse, as validated by the in situ and ex situ microscopy observations. Features extracted from such activity were cross-correlated both with the available mechanical and microscopy data, as well as with the Acoustic Emission activity recorded at the laboratory scale for similarly prepared specimens. The overall approach demonstrates that the method of Acoustic Emission could provide real time volumetric information related to the activation of deformation twinning in Magnesium alloys, in spite of the complexity of the propagation phenomena, the possible activation of several deformation modes and the challenges posed by the sensing approach itself when applied in this type of materials evaluation approach. PMID:28773786
NASA Astrophysics Data System (ADS)
Kim, Eun-Hye; Yang, Chan-Woo; Park, Jin-Woo
2012-05-01
In this study, we investigate the effect of interlayers on the mechanical properties of transparent conductive oxide (TCO) on flexible polymer substrates. Indium tin oxide (ITO), which is the most widely used TCO film, and Ti, which is the most widely used adhesive interlayer, are selected as the coating and the interlayer, respectively. These films are deposited on the polymer substrates using dc-magnetron sputtering to achieve varying thicknesses. The changes in the following critical factors for film cracking and delamination are analyzed: the internal stress (σi) induced in the coatings during deposition using a white light interferometer, the crystallinity using a transmission electron microscope, and the surface roughness of ITO caused by the interlayer using an atomic force microscope. The resistances to the cracking and delamination of ITO are evaluated using a fragmentation test. Our tests and analyses reveal the important role of the interlayers, which significantly reduce the compressive σi that is induced in the ITO and increase the resistance to the buckling delamination of the ITO. However, the relaxation of σi is not beneficial to cracking because there is less compensation for the external tension as σi further decreases. Based on these results, the microstructural control is revealed as a more influential factor than σi for improving crack resistance.
Richter, Johan C O; Haj-Hosseini, Neda; Hallbeck, Martin; Wårdell, Karin
2017-06-01
Visualization of the tumor is crucial for differentiating malignant tissue from healthy brain during surgery, especially in the tumor marginal zone. The aim of the study was to introduce a fluorescence spectroscopy-based hand-held probe (HHF-probe) for tumor identification in combination with the fluorescence guided resection surgical microscope (FGR-microscope), and evaluate them in terms of diagnostic performance and practical aspects of fluorescence detection. Eighteen operations were performed on 16 patients with suspected high-grade glioma. The HHF-probe and the FGR-microscope were used for detection of protoporphyrin (PpIX) fluorescence induced by 5-aminolevulinic acid (5-ALA) and evaluated against histopathological analysis and visual grading done through the FGR-microscope by the surgeon. A ratio of PpIX fluorescence intensity to the autofluorescence intensity (fluorescence ratio) was used to quantify the spectra detected by the probe. Fluorescence ratio medians (range 0 - 40) measured by the probe were related to the intensity of the fluorescence in the FGR-microscope, categorized as "none" (0.3, n=131), "weak" (1.6, n=34) and "strong" (5.4, n=28). Of 131 "none" points in the FGR-microscope, 88 (67%) exhibited fluorescence with the HHF-probe. For the tumor marginal zone, the area under the receiver operator characteristics (ROC) curve was 0.49 for the FGR-microscope and 0.65 for the HHF-probe. The probe was integrated in the established routine of tumor resection using the FGR-microscope. The HHF-probe was superior to the FGR-microscope in sensitivity; it detected tumor remnants after debulking under the FGR-microscope. The combination of the HHF-probe and the FGR-microscope was beneficial especially in the tumor marginal zone. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Naji, Ghassan Abdul-Hamid; Omar, Ros Anita; Yahya, Rosiyah
2017-03-01
In all-ceramic systems, a high incidence of veneer chip-off has been reported in clinical studies. Coefficient of thermal expansion (CTE) behaviour is one of the factors that may increase residual stress in the interface and influence the veneer/core bond strength. Therefore, this study aimed to evaluate the effect of sodalite zeolite-infiltration on the CTE behaviour and bond strength of different all-ceramic prostheses. The case-study groups were synthesized sodalite zeolite-infiltrated alumina (IA-SOD) and synthesized sodalite zeolite-infiltrated zirconia-toughened alumina (ZTA) (IZ-SOD), while the control groups were glass-infiltrated alumina (IA-glass) and glass-infiltrated ZTA (IZ-glass). Forty cylindrical-shaped samples measuring 5 mm in diameter and 10 mm in height were tested for CTE using a thermo-mechanical analyser machine, and forty disc-shaped ceramic samples measuring 12 mm in diameter and 1.2 ± 0.2 mm in thickness were prepared using specially designed stainless steel split mould and veneered by cylinder-shaped (2 mm high × 2 mm diameter) low-fusing porcelain (Vita VM7). The veneer/core samples were sintered and tested for shear bond strength using a high precision universal testing machine. Scanning electron microscope, stereo microscope, atomic force microscope, and energy-dispersive X-ray spectroscopy were used to investigate the structural characteristics of samples at the fracture surface. The collected data were analyzed with a one-way ANOVA and Tukey HSD test (α=.05). IZ-SOD revealed highest CTE and shear bond strength values, while the IA-glass revealed the lowest values than the other groups. There was no significant difference in CTE and bond strength among IZ-SOD, IA-SOD and IZ-glass samples (p>0.05). The experimental SOD zeolite-infiltrated samples revealed higher CTE mismatch and bond strength along with a more favourable mode of failure than did the commercial glass-infiltrated samples. Sandblast technique is considered as effective conditioning procedure for enhancing the surface roughness of SOD zeolite-infiltrated frameworks which subsequently improving the bond strength. Copyright © 2016 Elsevier Ltd. All rights reserved.
Bond strength and interactions of machined titanium-based alloy with dental cements.
Wadhwani, Chandur; Chung, Kwok-Hung
2015-11-01
The most appropriate luting agent for restoring cement-retained implant restorations has yet to be determined. Leachable chemicals from some types of cement designed for teeth may affect metal surfaces. The purpose of this in vitro study was to evaluate the shear bond strength and interactions of machined titanium-based alloy with dental luting agents. Eight dental luting agents representative of 4 different compositional classes (resin, polycarboxylate, glass ionomer, and zinc oxide-based cements) were used to evaluate their effect on machined titanium-6 aluminum-4 vanadium (Ti-6Al-4V) alloy surfaces. Ninety-six paired disks were cemented together (n=12). After incubation in a 37°C water bath for 7 days, the shear bond strength was measured with a universal testing machine (Instron) and a custom fixture with a crosshead speed of 5 mm/min. Differences were analyzed statistically with 1-way ANOVA and Tukey HSD tests (α=.05). The debonded surfaces of the Ti alloy disks were examined under a light microscope at ×10 magnification to record the failure pattern, and the representative specimens were observed under a scanning electron microscope. The mean ±SD of shear failure loads ranged from 3.4 ±0.5 to 15.2 ±2.6 MPa. The retention provided by both polycarboxylate cements was significantly greater than that of all other groups (P<.05). The scanning electron microscope examination revealed surface pits only on the bonded surface cemented with the polycarboxylate cements. Cementation with polycarboxylate cement obtained higher shear bond strength. Some chemical interactions occurred between the machined Ti-6Al-4V alloy surface and polycarboxylate cements during cementation. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Módis, László; Szalai, Eszter; Németh, Gábor; Berta, András
2010-01-01
The study was conducted to assess the central corneal thickness (CCT) of the healthy cornea with a recently developed noncontact specular microscope (EM-3000; Tomey) and compare the results with those measured with a contact specular microscope and an ultrasound pachymeter. Agreement between measurements taken by 2 investigators was also studied. The right eyes of 41 healthy individuals who had negative history of contact lens wear, ophthalmic disease, or ocular surgery were examined. The CCT was determined sequentially with a noncontact specular microscope, a contact specular microscope (EM-1000; Tomey), and an ultrasound pachymeter (AL-2000; Tomey). Each evaluation with the specular microscopes was performed by 2 independent operators. A significant difference was detected in pachymetry measurements among the 3 instruments (p=0.01; analysis of variance). The mean CCT values were lower measured with the ultrasound pachymeter (537+/-30 microm) than the contact endothelial microscope (543+/-37 microm, p=0.17, Student t-test) and the noncontact microscope (549+/-33 microm, p<0.0001) (operator 1). There was no statistically significant difference in CCT measurements between the 2 endothelial microscopes (p=0.19). We found significant correlations (p<0.0001) in thickness measurements between each pair of instruments (r=0.91, noncontact microscopy and ultrasound pachymetry; r=0.74, noncontact and contact microscopy; r=0.72, contact microscopy and ultrasound pachymetry; Spearman rank correlation). The strong correlations among the 3 pachymetry devices suggest that the tested instruments provide reliable measurements; however, they cannot be used interchangeably.
An investigation of the compressive strength of Kevlar 49/epoxy composites
NASA Technical Reports Server (NTRS)
Kulkarni, S. V.; Rosen, B. W.; Rice, J. S.
1975-01-01
Tests were performed to evaluate the effect of a wide range of variables including matrix properties, interface properties, fiber prestressing, secondary reinforcement, and others on the ultimate compressive strength of Kevlar 49/epoxy composites. Scanning electron microscopy is used to assess the resulting failure surfaces. In addition, a theoretical study is conducted to determine the influence of fiber anisotropy and lack of perfect bond between fiber and matrix on the shear mode microbuckling. The experimental evaluation of the effect of various constituent and process characteristics on the behavior of these unidirectional composites in compression did not reveal any substantial increase in strength. However, theoretical evaluations indicate that the high degree of fiber anisotropy results in a significant drop in the predicted stress level for internal instability. Scanning electron microscope data analysis suggests that internal fiber failure and smooth surface debonding could be responsible for the measured low compressive strengths.
Fast and Adaptive Auto-focusing Microscope
NASA Astrophysics Data System (ADS)
Obara, Takeshi; Igarashi, Yasunobu; Hashimoto, Koichi
Optical microscopes are widely used in biological and medical researches. By using the microscope, we can observe cellular movements including intracellular ions and molecules tagged with fluorescent dyes at a high magnification. However, a freely motile cell easily escapes from a 3D field of view of the typical microscope. Therefore, we propose a novel auto-focusing algorithm and develop a auto-focusing and tracking microscope. XYZ positions of a microscopic stage are feedback controlled to focus and track the cell automatically. A bright-field image is used to estimate a cellular position. XY centroids are used to estimate XY positions of the tracked cell. To estimate Z position, we use a diffraction pattern around the cell membrane. This estimation method is so-called Depth from Diffraction (DFDi). However, this method is not robust for individual differences between cells because the diffraction pattern depends on each cellular shape. Therefore, in this study, we propose a real-time correction of DFDi by using 2D Laplacian of an intracellular area as a goodness of the focus. To evaluate the performance of our developed algorithm and microscope, we auto-focus and track a freely moving paramecium. In this experimental result, the paramecium is auto-focused and kept inside the scope of the microscope during 45s. The evaluated focal error is within 5µm, while a length and a thickness of the paramecium are about 200µm and 50µm, respectively.
NASA Astrophysics Data System (ADS)
Rajkuberan, Chandrasekaran; Sudha, Kannaiah; Sathishkumar, Gnanasekar; Sivaramakrishnan, Sivaperumal
2015-02-01
The present study aimed to synthesis silver nanoparticles (AgNPs) in a greener route using aqueous latex extract of Calotropis gigantea L. toward biomedical applications. Initially, synthesis of AgNPs was confirmed through UV-Vis spectroscopy which shows the surface plasmonic resonance peak (SPR) at 420 nm. Fourier transform infrared spectroscopy (FTIR) analysis provides clear evidence that protein fractions present in the latex extract act as reducing and stabilizing bio agents. Energy dispersive X-ray (EDAX) spectroscopy confirms the presence of silver as a major constituent element. X-ray diffractograms displays that the synthesized AgNPs were biphasic crystalline nature. Electron microscopic studies such as Field emission scanning electron microscopic (Fe-SEM) and Transmission electron microscope (TEM) reveals that synthesized AgNPs are spherical in shape with the size range between 5 and 30 nm. Further, crude latex aqueous extract and synthesized AgNPs were evaluated against different bacterial pathogens such as Bacillus cereus, Enterococci sp, Shigella sp, Pseudomonas aeruginosa, Klebsiella pneumonia, Staphylococcus aureus and Escherichia coli. Compared to the crude latex aqueous extract, biosynthesized AgNPs exhibits a remarkable antimicrobial activity. Likewise invitro anticancer study manifests the cytotoxicity value of synthesized AgNPs against tested HeLa cells. The output of this study clearly suggesting that biosynthesized AgNPs using latex of C. gigantea can be used as promising nanomaterial for therapeutic application in context with nanodrug formulation.
Gürbüzer, Bahadir; Pikdöken, Levent; Tunali, Mustafa; Urhan, Muammer; Küçükodaci, Zafer; Ercan, Feriha
2010-05-01
To evaluate the effect of platelet-rich fibrin (PRF) on the early bone healing process with bone scintigraphy based on technetium-99m methylene diphosphonate uptake in third molar extraction sockets. Fourteen patients with bilaterally soft tissue impacted third mandibular molars were included in the study. The right and left impacted third molars were surgically extracted in the same session. PRF was randomly administered into one of the extraction sockets, whereas the contralateral sockets were left without treatment. Four weeks after surgery, scintigrams were obtained to evaluate scintigraphic differences between PRF-treated and non-PRF-treated sockets. After completion of the clinical study, PRF samples were evaluated by light and scanning electron microscopy. The average increase in technetium-99m methylene diphosphonate uptake as an indication of enhanced bone healing did not differ significantly between PRF-treated and non-PRF-treated sockets 4 weeks postoperatively (P > .05). Abundant fibrin and inflammatory cells were observed by light microscopic examination of PRF samples. Scanning electron microscopic analysis of PRF revealed the existence of platelet aggregates in a fibrin network and crystalline particles on the outer surface of PRF. PRF might not lead to enhanced bone healing in soft tissue impacted mandibular third molar extraction sockets 4 weeks after surgery. PRF exhibits the potential characteristics of an autologous fibrin matrix. However, whether the presence of crystal-like particles on the outer surface of PRF alters bone healing should be investigated further. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Optimal resolution in Fresnel incoherent correlation holographic fluorescence microscopy
Brooker, Gary; Siegel, Nisan; Wang, Victor; Rosen, Joseph
2011-01-01
Fresnel Incoherent Correlation Holography (FINCH) enables holograms and 3D images to be created from incoherent light with just a camera and spatial light modulator (SLM). We previously described its application to microscopic incoherent fluorescence wherein one complex hologram contains all the 3D information in the microscope field, obviating the need for scanning or serial sectioning. We now report experiments which have led to the optimal optical, electro-optic, and computational conditions necessary to produce holograms which yield high quality 3D images from fluorescent microscopic specimens. An important improvement from our previous FINCH configurations capitalizes on the polarization sensitivity of the SLM so that the same SLM pixels which create the spherical wave simulating the microscope tube lens, also pass the plane waves from the infinity corrected microscope objective, so that interference between the two wave types at the camera creates a hologram. This advance dramatically improves the resolution of the FINCH system. Results from imaging a fluorescent USAF pattern and a pollen grain slide reveal resolution which approaches the Rayleigh limit by this simple method for 3D fluorescent microscopic imaging. PMID:21445140
Stoicescu, Adriana; Andrei, M; Becheanu, G; Stoicescu, M; Nicolaie, T; Diculescu, M
2012-01-01
Some patients previously diagnosed with irritable bowel syndrome (IBS) may develop microscopic colitis or small intestinal bacterial overgrowth (SIBO). To estimate the prevalence of microscopic colitis and SIBO in patients with IBS, to evaluate the symptoms and the efficacy of treatment. We examined patients with IBS admitted in our clinic during a three-year period. We identified patients with microscopic colitis by performing total colonoscopy with multiple biopsies from normal intestinal mucosa and those with SIBO by performing a H2-breath test with glucose. We compared the symptoms and the effectiveness of the treatment. Out of the 132 patients initially diagnosed with IBS 3% (n=4) had microscopic colitis and 43.9% (n=58) had SIBO. Diarrhea was the main symptom in patients with microscopic colitis and SIBO (p=0.041), while abdominal pain, abdominal bloating and flatulence were prominent in IBS patients (p=0.042; p=0.039; p=0.048). Specific treatment with rifaximin in SIBO patients negativated H2-breath test in 70.9% cases. Patients suspected to have irritable bowel syndrome should be evaluated for microscopic colitis and SIBO. The proper diagnosis and the specific treatment may cure some difficult cases of the so called "irritable bowel syndrome".
Chandrappa, Mahesh Martur; Meharwade, Prasanna Mahadevasa; Srinivasan, Raghu; Bhandary, Shreetha; Nasreen, Farhat
2016-01-01
The objective of this study was to evaluate the effectiveness of 5.25% sodium hypochlorite (NaOCl), 2% chlorhexidine (CHX), and 2% peracetic acid (PAA) in disinfecting Resilon cones and to evaluate topographical changes microscopically under scanning electron microscope (SEM) after rapid chemical disinfection. Resilon cones were disinfected in an ultraviolet (UV) light chamber for 20 min and contaminated by immersing in a microbial suspension of Enterococcus faecalis for 30 min. The contaminated cones were then immersed in the 5.25% NaOCl, 2% CHX, and 2% PAA for 1 min, 5 min, and 10 min, separately. The cones were then incubated at 37°C in thioglycollate broth for 7 days and examined for turbidity. The samples showing turbidity were subcultured on blood agar and incubated at 37°C for 48 h. Gram staining was done to confirm that the cultured bacteria were E. faecalis. Surface changes of disinfected Resilon cones were evaluated under SEM. The data were analyzed statistically using Kruskal-Wallis, analysis of variance (ANOVA), and Mann-Whitney U-test. In eliminating E. faecalis, 5.25% NaOCl was most effective followed by 2% PAA and 2% CHX. Topographic examination of tested Resilon cones revealed some surface deposits after disinfection with 5.25% NaOCl and 2% CHX, whereas 2% PAA caused surface erosion. In disinfecting Resilon cones, 5.25% NaOCl is most effective followed by 2% PAA and 2% CHX.
The Evaluation of a New Approach to Teaching Microscopic Anatomy. Final Report.
ERIC Educational Resources Information Center
Scranton, James R.
This project was a partial evaluation of the new approach to teaching medical microscopic anatomy developed at the University of Iowa. The format of the course included specific objectives given to the students in advance, with the main sources of information coming from independent readings and laboratory exercises, demonstration of mastery of…
Desai, Nandini J.; Gupta, B. D.; Patel, Pratik Narendrabhai
2014-01-01
Introduction: Obtaining images of slides viewed by a microscope can be invaluable for both diagnosis and teaching.They can be transferred among technologically-advanced hospitals for further consultation and evaluation. But a standard microscopic photography camera unit (MPCU)(MIPS-Microscopic Image projection System) is costly and not available in resource poor settings. The aim of our endeavour was to find a comparable and cheaper alternative method for photomicrography. Materials and Methods: We used a NIKON Coolpix S6150 camera (box type digital camera) with Olympus CH20i microscope and a fluorescent microscope for the purpose of this study. Results: We got comparable results for capturing images of light microscopy, but the results were not as satisfactory for fluorescent microscopy. Conclusion: A box type digital camera is a comparable, less expensive and convenient alternative to microscopic photography camera unit. PMID:25478350
Scanning electron microscopic study of a Ciloxan bottle blocked by ciprofloxacin crystals.
John, T
2001-12-01
To report blockage of a commercially available ciprofloxacin bottle by white crystalline deposits. This study evaluated the ultrastructural features of the ciprofloxacin crystals. A patient underwent intensive topical treatment of an infectious corneal ulcer with commercially available ciprofloxacin 0.3% ophthalmic solution. During treatment, the patient was unable to obtain medication from the ciprofloxacin bottle and required a new prescription. Examination of the bottle revealed that about 50% of the medication remained, but compression of the bottle with any amount of force failed to deliver any medication. On closer examination, a white material partially filled the nozzle track of the bottle and was on the outer bottle near the nozzle and the inner surface of the bottle cap. These white crystalline deposits were evaluated by scanning electron microscopy. Plate-like, needle, cable and spaghetti-like crystals were found. The needle crystals formed multiple petaloid patterns. This is the first report of blockage of a commercially available ciprofloxacin 0.3% bottle by ciprofloxacin crystals and the inability to deliver medication from the bottle. Ultrastructural study of the white crystalline deposits revealed four types of ciprofloxacin crystals.
NASA Astrophysics Data System (ADS)
Wen, Jing; Ma, Haibo
2017-07-01
For computing the intra-chain excitonic couplings in polymeric systems, here we propose a new fragmentation approach. A comparison for the energetic and spatial properties of the low-lying excited states in PPV between our scheme and full quantum chemical calculations, reveals that our scheme can nicely reproduce full quantum chemical results in weakly coupled systems. Further wavefunction analysis indicate that improved description for strongly coupled system can be achieved by the inclusion of the higher excited states within each fragments. Our proposed scheme is helpful for building the bridge linking the phenomenological descriptions of excitons and microscopic modeling for realistic polymers.
Evaluation of synthetic linear motor-molecule actuation energetics
Brough, Branden; Northrop, Brian H.; Schmidt, Jacob J.; Tseng, Hsian-Rong; Houk, Kendall N.; Stoddart, J. Fraser; Ho, Chih-Ming
2006-01-01
By applying atomic force microscope (AFM)-based force spectroscopy together with computational modeling in the form of molecular force-field simulations, we have determined quantitatively the actuation energetics of a synthetic motor-molecule. This multidisciplinary approach was performed on specifically designed, bistable, redox-controllable [2]rotaxanes to probe the steric and electrostatic interactions that dictate their mechanical switching at the single-molecule level. The fusion of experimental force spectroscopy and theoretical computational modeling has revealed that the repulsive electrostatic interaction, which is responsible for the molecular actuation, is as high as 65 kcal·mol−1, a result that is supported by ab initio calculations. PMID:16735470
Amphibian ocular malformation associated with frog virus 3.
Burton, Elizabeth C; Miller, Debra L; Styer, Eloise L; Gray, Matthew J
2008-09-01
During an on-going amphibian ecology study, a free-ranging American bullfrog (Rana catesbeiana) metamorph was captured in a pitfall trap adjacent to a constructed farm pond at the Plateau Research and Education Center (PREC) on the Cumberland Plateau near Crossville, Tennessee, USA. Grossly, the right eye was approximately 50% the size of the left. Stereo and light microscopic examination revealed two granulomas within the orbit. Electron microscopic examination revealed virus particles scattered throughout one structure but mostly aggregated toward the center. Subsequent PCR and sequencing (GenBank accession Number EF175670) confirmed frog virus 3 (FV3). This represents the first report of a malformation in an anuran associated with FV3.
Dynamic views of living cell fine structure revealed by birefringence imaging
NASA Astrophysics Data System (ADS)
Oldenbourg, Rudolf
2001-11-01
We have been developing and applying a new type of polarized light microscope, the new Pol-Scope, which dramatically enhances the unique capabilities of the traditional polarizing microscope. In living cells, without applying exogenous dyes or florescent labels, we have studied the dynamic organization of filamentous actin in neuronal growth cones and improved the efficiency of spindle imaging for in-vitro fertilization and enucleation procedures.
Electron microscope evidence of virus infection in cultured marine fish
NASA Astrophysics Data System (ADS)
Sun, Xiu-Qin; Zhang, Jin-Xing; Qu, Ling-Yun
2000-09-01
Electron microscope investigation on the red sea bream ( Pagrosomus major), bastard halibut ( Paralichthys olivaceus) and stone flounder ( Kareius bicoloratus) in North China revealed virus infection in the bodies of the dead and diseased fish. These viruses included the lymphocystis disease virus (LDV), parvovirus, globular virus, and a kind of baculavirus which was not discovered and reported before and is now tentatively named baculavirus of stone flounder ( Kareius bicoloratus).
Dental microwear textures: reconstructing diets of fossil mammals
NASA Astrophysics Data System (ADS)
DeSantis, Larisa R. G.
2016-06-01
Dietary information of fossil mammals can be revealed via the analysis of tooth morphology, tooth wear, tooth geochemistry, and the microscopic wear patterns on tooth surfaces resulting from food processing. Although dental microwear has long been used by anthropologists and paleontologists to clarify diets in a diversity of mammals, until recently these methods focused on the counting of wear features (e.g., pits and scratches) from two-dimensional surfaces (typically via scanning electron microscopes or low-magnification light microscopes). The analysis of dental microwear textures can instead reveal dietary information in a broad range of herbivorous, omnivorous, and carnivorous mammals by characterizing microscopic tooth surfaces in three-dimensions, without the counting of individual surface features. To date, dental microwear textures in ungulates, xenarthrans, marsupials, carnivorans, and primates (including humans and their ancestors) are correlated with known dietary behavior in extant taxa and reconstruct ancient diets in a diversity of prehistoric mammals. For example, tough versus hard object feeding can be characterized across disparate phylogenetic groups and can distinguish grazers, folivorous, and flesh consumers (tougher food consumers) from woody browsers, frugivores, and bone consumers (harder object feeders). This paper reviews how dental microwear textures can be useful to reconstructing diets in a broad array of living and extinct mammals, with commentary on areas of future research.
Yu, Kun-Zi; Yan, Hua; Tai, Hai-Chuan; Zhang, Nan-Ping; Cheng, Xian-Long; Guo, Zeng-Xi; Ma, Shuang-Cheng; Wei, Feng
2017-07-01
The Chinese Materia Medica, Tiepishihu, used as a tonic for over one thousand years, is a well-known precious medicine in China. According to the Chinese Pharmacopoeia, its source is the species Dendrobium officinale Kimura et Migo, which is distinguished from other species in Dendrobium genus. However, these species from the same genus are similar with Tiepishihu and caused confusion in the market. To find a quick and simple method to distinguish Tiepishihu from other similar species, histologic and microscopic methods were combined together to investigate the transverse section of stem of Tiepishihu and other similar species. Phloroglucinol test solution with hydrochloric acid was used to reveal the lignified tissue by staining the transverse section of Tiepishihu and similar species. Results revealed the unique identification characteristics to distinguish Tiepishihu from similar species, which were difficult to distinguish by other methods. The identification characteristics of Tiepishihu include the cells of vascular bundle sheath were stained red, parenchyma cells were not stained red. What's more, other species can be distinguished from each other with microscopic and histological characteristics. These characteristics proved stable and can be easily observed by normal light microscopic examination. This method is rapid, accurate, stable, and inexpensive. © 2017 Wiley Periodicals, Inc.
Highly dispersible diamond nanoparticles for pretreatment of diamond films on Si substrate
NASA Astrophysics Data System (ADS)
Zhao, Shenjie; Huang, Jian; Zhou, Xinyu; Ren, Bing; Tang, Ke; Xi, Yifan; Wang, Lin; Wang, Linjun; Lu, Yicheng
2018-03-01
High quality diamond film on Si substrate was synthesized by coating diamond nanoparticles prepared by polyglycerol grafting (ND-PG) dispersion as pre-treatment method. Transmission electron microscope indicates that ND-PG is much more dispersible than untreated nanoparticles in organic solvents. The surface morphology was characterized by scanning electron microscope while atomic force microscope was conducted to measure the surface roughness. Microstructure properties were carried out by Raman spectroscopy and X-ray diffraction. The results revealed an increase in nucleation density, an acceleration of growth rate and an improvement of film crystalline quality by using spin-coating ND-PG pretreatment.
Plasma sprayed Fe(76)Nd(16)B(8) permanent magnets
NASA Technical Reports Server (NTRS)
Overfelt, R. A.; Anderson, C. D.; Flanagan, W. F.
1986-01-01
Thin coatings (0.16 mm) and thick coatings (0.50 mm) of Fe(76)Nd(16)B(8) were deposited on stainless-steel substrates by low pressure plasma spraying. Microscopic examination of the coatings in a light microscope revealed excessive porosity, but good bonding to the substrate. Fracture cross sections examined in a scanning electron microscope showed the grains to be equiaxed and approximately 1 micron or less in diameter in the as-sprayed condition. The intrinsic coercivities of the as-sprayed coatings varied from 5.8 to 10.9 kOe. The effects of postspray heat treatments on the intrinsic coercivity are also given.
Controlling electrostatic charging of nanocrystalline diamond at nanoscale.
Verveniotis, Elisseos; Kromka, Alexander; Rezek, Bohuslav
2013-06-11
Constant electrical current in the range of -1 to -200 pA is applied by an atomic force microscope (AFM) in contact mode regime to induce and study local electrostatic charging of oxygen-terminated nanocrystalline diamond (NCD) thin films. The NCD films are deposited on silicon in 70 nm thickness and with 60% relative sp(2) phase content. Charging current is monitored by conductive AFM. Electric potential contrast induced by the current is evaluated by Kelvin force microscopy (KFM). KFM shows well-defined, homogeneous, and reproducible microscopic patterns that are not influenced by inherent tip-surface junction fluctuations during the charging process. The charged patterns are persistent for at least 72 h due to charge trapping inside the NCD film. The current-induced charging also clearly reveals field-induced detrapping at current amplitudes >-50 pA and tip instability at >-150 pA, both of which limit the achievable potential contrast. In addition, we show that the field also determines the range of electronic states that can trap the charge. We present a model and discuss implications for control of the nanoscale charging process.
Combining spiral and target wave detection to analyze excitable media dynamics
NASA Astrophysics Data System (ADS)
Geberth, Daniel; Hütt, Marc-Thorsten
2010-01-01
Excitable media dynamics is the lossless active transmission of waves of excitation over a field of coupled elements, such as electrical excitation in heart tissue or nerve fibers, cAMP signaling in the slime mold Dictyostelium discoideum or waves of chemical activity in the Belousov-Zhabotinsky reaction. All these systems follow essentially the same generic dynamics, including undamped wave transmission and the self-organized emergence of circular target and self-sustaining spiral waves. We combine spiral recognition, using the established phase singularity technique, and a novel three-dimensional fitting algorithm for noise-resistant target wave recognition to extract all important events responsible for the layout of the asymptotic large-scale pattern. Space-time plots of these combined events reveal signatures of events leading to spiral formation, illuminating the microscopic mechanisms at work. This strategy can be applied to arbitrary excitable media data from either models or experiments, giving insight into for example the microscopic causes for formation of pathological spiral waves in heart tissue, which could lead to novel techniques for diagnosis, risk evaluation and treatment.
Plasmodium malariae in the Colombian Amazon region: you don't diagnose what you don't suspect.
Niño, Carlos Hernando; Cubides, Juan Ricardo; Camargo-Ayala, Paola Andrea; Rodríguez-Celis, Carlos Arturo; Quiñones, Teódulo; Cortés-Castillo, Moisés Tomás; Sánchez-Suárez, Lizeth; Sánchez, Ricardo; Patarroyo, Manuel Elkin; Patarroyo, Manuel Alfonso
2016-11-29
Malaria is a worldwide public health problem; parasites from the genus Plasmodium spp. are the aetiological agent of this disease. The parasite is mainly diagnosed by microscope-based techniques. However, these have limited sensitivity. Many asymptomatic infections are sub-microscopic and can only be detected by molecular methods. This study was aimed at comparing nested PCR results to those obtained by microscope for diagnosing malaria and to present epidemiological data regarding malaria in Colombia's Amazon department. A total of 1392 blood samples (taken by venepuncture) from symptomatic patients in Colombia's Amazon department were analysed in parallel by thick blood smear (TBS) test and nested PCR for determining Plasmodium spp. infection and identifying infecting species, such as Plasmodium vivax, Plasmodium malariae and/or Plasmodium falciparum. Descriptive statistics were used for comparing the results from both tests regarding detection of the disease, typing infecting species and their prevalence in the study region. Bearing the microscope assay in mind as gold standard, PCR diagnosis performance was evaluated by statistical indicators. The present study revealed great differences between both diagnostic tests, as well as suggesting high P. malariae prevalence from a molecular perspective. This differed profoundly from previous studies in this region of Colombia, usually based on the TBS test, suggesting that diagnosis by conventional techniques could lead to underestimating the prevalence of certain Plasmodium spp. having high circulation in this area. The present results highlight the need for modifying state malaria surveillance schemes for more efficient strategies regarding the detection of this disease in endemic areas. The importance of PCR as a back-up test in cases of low parasitaemia or mixed infection is also highlighted.
Abuabara, Allan; Baratto-Filho, Flares; Aguiar Anele, Juliana; Leonardi, Denise Piotto; Sousa-Neto, Manoel Damião
2013-01-01
The success of endodontic treatment depends on the identification of all root canals. Technological advances have facilitated this process as well as the assessment of internal anatomical variations. The aim of this study was to compare the efficacy of clinical and radiological methods in locating second mesiobuccal canals (MB2) in maxillary first molars. Fifty patients referred for analysis; access and clinical analysis; cone-beam endodontic treatment of their maxillary first molars were submitted to the following assessments: analysis; access and clinical analysis; cone-beam computed tomography (CBCT); post-CBCT clinical analysis; clinical analysis using an operating microscope; and clinical analysis after Start X ultrasonic inserts in teeth with negative results in all previous analyses. Periapical radiographic analysis revealed the presence of MB2 in four (8%) teeth, clinical analysis in 25 (50%), CBCT analysis in 27 (54%) and clinical analysis following CBCT and using an operating microscope in 27 (54%) and 29 (58%) teeth, respectively. The use of Start X ultrasonic inserts allowed one to detect two additional teeth with MB2 (62%). According to Vertucci's classification 48% of the mesiobuccal canals found were type I, 28% type II, 18% type IV and 6% type V. Statistical analysis showed no significant differences (p > 0.5) in the ability of CBCT to detect MB2 canals when compared with clinical assessment with or without an operating microscope. A significant difference (p < 0.001)was found only between periapical radiography and clinical/CBCT evaluations. Combined use of different methods increased the detection ofthe second canal in MB roots, but without statistical difference among CBCT, operating microscope, Start X and clinical analysis.
Shiloh, Roy; Remez, Roei; Lu, Peng-Han; Jin, Lei; Lereah, Yossi; Tavabi, Amir H; Dunin-Borkowski, Rafal E; Arie, Ady
2018-06-01
Nearly eighty years ago, Scherzer showed that rotationally symmetric, charge-free, static electron lenses are limited by an unavoidable, positive spherical aberration. Following a long struggle, a major breakthrough in the spatial resolution of electron microscopes was reached two decades ago by abandoning the first of these conditions, with the successful development of multipole aberration correctors. Here, we use a refractive silicon nitride thin film to tackle the second of Scherzer's constraints and demonstrate an alternative method for correcting spherical aberration in a scanning transmission electron microscope. We reveal features in Si and Cu samples that cannot be resolved in an uncorrected microscope. Our thin film corrector can be implemented as an immediate low cost upgrade to existing electron microscopes without re-engineering of the electron column or complicated operation protocols and can be extended to the correction of additional aberrations. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
The maxillary molar endodontic access opening: A microscope-based approach
Mamoun, John Sami
2016-01-01
This article reviews the basic clinical techniques of performing a maxillary molar endodontic access opening, starting from the initial access opening into the pulp chamber, to the point where a size #10 file has been advanced to the apices of all three or four (or more) canals. The article explains how the use of the dental surgical operating microscope or microscope-level loupes magnification of ×6–8 or greater, combined with head-mounted or coaxial illumination, improve the ability of a dentist to identify microscopic root canal orifices, which facilitates the efficient creation of conservative access openings with adequate straight-line access in maxillary molars. Magnified photos illustrate various microscopic anatomical structures or landmarks of the initial access opening. Techniques are explored for implementing an access opening for teeth with vital versus necrotic pulpal tissues. The article also explores the use of piezoelectric or ultrasonic instruments for revealing root canal orifices and for removing pulp stones or calcified pulpal tissue inside the pulp chamber. PMID:27403069
Experiments on terahertz 3D scanning microscopic imaging
NASA Astrophysics Data System (ADS)
Zhou, Yi; Li, Qi
2016-10-01
Compared with the visible light and infrared, terahertz (THz) radiation can penetrate nonpolar and nonmetallic materials. There are many studies on the THz coaxial transmission confocal microscopy currently. But few researches on the THz dual-axis reflective confocal microscopy were reported. In this paper, we utilized a dual-axis reflective confocal scanning microscope working at 2.52 THz. In contrast with the THz coaxial transmission confocal microscope, the microscope adopted in this paper can attain higher axial resolution at the expense of reduced lateral resolution, revealing more satisfying 3D imaging capability. Objects such as Chinese characters "Zhong-Hua" written in paper with a pencil and a combined sheet metal which has three layers were scanned. The experimental results indicate that the system can extract two Chinese characters "Zhong," "Hua" or three layers of the combined sheet metal. It can be predicted that the microscope can be applied to biology, medicine and other fields in the future due to its favorable 3D imaging capability.
ERIC Educational Resources Information Center
Leinonen, Risto; Asikainen, Mervi A.; Hirvonen, Pekka E.
2015-01-01
This study concentrates on evaluating the consistency of upper-division students' use of the second law of thermodynamics at macroscopic and microscopic levels. Data were collected by means of a paper and pencil test (N = 48) focusing on the macroscopic and microscopic features of the second law concerned with heat transfer processes. The data…
Portable, battery-operated, fluorescence field microscope for the developing world
NASA Astrophysics Data System (ADS)
Miller, Andrew R.; Davis, Gregory; Pierce, Mark; Oden, Z. Maria; Richards-Kortum, Rebecca
2010-02-01
In many areas of the world, current methods for diagnosis of infectious diseases such as malaria and tuberculosis involve microscopic evaluation of a patient specimen. Advances in fluorescence microscopy can improve diagnostic sensitivity and reduce time and expertise necessary to interpret diagnostic results. However, modern research-grade microscopes are neither available nor appropriate for use in many settings in the developing world. To address this need, we designed, fabricated, and tested a portable, battery-powered, bright field and fluorescence inverted field microscope, optimized for infrastructural constraints of the developing world. We characterized an initial prototype constructed with rapidprototyping techniques, which utilized low-cost, over-the-counter components such as a battery-powered LED flashlight as the light source. The microscope exhibited suitable spatial resolution (0.8 μm) in fluorescence mode to resolve M. tuberculosis bacilli. In bright field mode, malaria parasites were resolvable at 1000x magnification. The initial prototype cost 480 USD and we estimate that the microscope can be manufactured for 230 USD. While future studies are planned to evaluate ease-of-use and reliability, our current system serves as a proof of concept that combined fluorescence and bright field microscopy is possible in a low-cost and portable system.
Multifocal colitis associated with an epidemic of chronic diarrhea.
Janda, R C; Conklin, J L; Mitros, F A; Parsonnet, J
1991-02-01
An outbreak of a chronic diarrheal syndrome was detected between May and August 1987 in rural Henderson County, Illinois. Seventy-two individuals were affected. Epidemiological studies performed by the Center for Disease Control implicated the water of a local restaurant as the source of the outbreak. Five patients underwent a comprehensive evaluation. Their mean age was 51 years, and they had a mean of 12 watery stools daily (range, 6-40). Detailed microbiological evaluations failed to identify a pathological organism. Stool studies showed a mean stool weight of 392 g/24 h with a normal fat content. Results of all biochemical studies of serum were normal. Chemical analysis of stool water suggested a secretory diarrhea. Colonoscopy revealed patchy erythema, and light microscopic examination of colonic biopsy specimens revealed multifocal areas of acute inflammation in the superficial mucosa in 4 of 5 patients. Electron microscopy of the affected areas revealed no viral particles. After 2 years, all of our patients continued to experience chronic diarrhea. One patient agreed to a follow-up colonoscopy; histological abnormalities of the colonic mucosa persisted after 2 years. We speculate that an infectious process arising from a contaminated water system induced a chronic, secretory diarrhea characterized by multifocal colitis. This histological abnormality may serve as a marker of an infectious, chronic diarrhea.
Clinical, microscopic, and molecular aspects of canine leproid granuloma in the United States.
Foley, J E; Borjesson, D; Gross, T L; Rand, C; Needham, M; Poland, A
2002-03-01
Leproid granulomas from seven dogs in the United States were evaluated. Gross characteristics included nodular and ulcerated dermal and subcutaneous lesions primarily on the caudal aspects of the pinnae and to a lesser extent on the muzzle, face, and forelimbs. In all except one dog, there was complete regression of the lesions within 6 months, either with no therapy or after surgical resection. Cytology or histopathology revealed pyogranulomatous inflammation with few to many acid-fast mycobacterial bacilli within macrophages. The organisms could not be cultivated in vitro. DNA sequencing of part of the 16S ribosomal RNA gene region revealed 99-100% homology among fragments from five of these dogs and fragments from dogs in the south Pacific. This syndrome occurs in dogs in North America and the prognosis is excellent, in contrast to the prognosis for rapid-growing or tuberculous mycobacteriosis.
Moore, Jayma A; Payne, Scott A
2012-01-01
Fungi often are found within plant tissues where they cannot be visualized with the scanning electron microscope (SEM). We present a simple way to reveal cell interiors while avoiding many common causes of artifact. Freeze-fracture of leaf tissue using liquid nitrogen during the 100% ethanol step of the dehydration process just before critical point drying is useful in exposing intracellular fungi to the SEM.
eeDAP: An Evaluation Environment for Digital and Analog Pathology.
Gallas, Brandon D; Cheng, Wei-Chung; Gavrielides, Marios A; Ivansky, Adam; Keay, Tyler; Wunderlich, Adam; Hipp, Jason; Hewitt, Stephen M
2014-01-01
The purpose of this work is to present a platform for designing and executing studies that compare pathologists interpreting histopathology of whole slide images (WSI) on a computer display to pathologists interpreting glass slides on an optical microscope. Here we present eeDAP, an evaluation environment for digital and analog pathology. The key element in eeDAP is the registration of the WSI to the glass slide. Registration is accomplished through computer control of the microscope stage and a camera mounted on the microscope that acquires images of the real time microscope view. Registration allows for the evaluation of the same regions of interest (ROIs) in both domains. This can reduce or eliminate disagreements that arise from pathologists interpreting different areas and focuses the comparison on image quality. We reduced the pathologist interpretation area from an entire glass slide (≈10-30 mm) 2 to small ROIs <(50 um) 2 . We also made possible the evaluation of individual cells. We summarize eeDAP's software and hardware and provide calculations and corresponding images of the microscope field of view and the ROIs extracted from the WSIs. These calculations help provide a sense of eeDAP's functionality and operating principles, while the images provide a sense of the look and feel of studies that can be conducted in the digital and analog domains. The eeDAP software can be downloaded from code.google.com (project: eeDAP) as Matlab source or as a precompiled stand-alone license-free application.
Iatrogenic surgical microscope skin burns: A systematic review of the literature and case report.
Lopez, Joseph; Soni, Ashwin; Calva, Daniel; Susarla, Srinivas M; Jallo, George I; Redett, Richard
2016-06-01
Cutaneous burns associated with microscope-use are perceived to be uncommon adverse events in microsurgery. Currently, it is unknown what factors are associated with these iatrogenic events. In this report, we describe the case of a 1-year-old patient who suffered a full thickness skin burn from a surgical microscope after a L4-S1 laminectomy. Additionally, we present a systematic review of the literature that assessed the preoperative risk, outcome, and management of iatrogenic microscope skin burns. Lastly, a summary of the Food and Drug Administration's (FDA) Manufacturer and User Facility Device Experience (MAUDE) database of voluntary adverse events was reviewed and analyzed for clinical cases of microscope thermal injuries. The systematic literature review identified only seven articles related to microsurgery-related cutaneous burns. From these seven studies, 15 clinical cases of iatrogenic skin burns were extracted for analysis. The systematic review of the FDA MAUDE database revealed only 60 cases of cutaneous burns associated with surgical microscopes since 2004. Few cases of microscope burns have been described in the literature; this report is, to our knowledge, one of the first comprehensive reports of this iatrogenic event in the literature. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
İnce, Fatma Demet; Ellidağ, Hamit Yaşar; Koseoğlu, Mehmet; Şimşek, Neşe; Yalçın, Hülya; Zengin, Mustafa Osman
2016-08-01
Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. 209 urine samples were analyzed by the Iris iQ200 ELITE (İris Diagnostics, USA), Dirui FUS-200 (DIRUI Industrial Co., China) automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient) and the rates within the same grading were evaluated. For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals) have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization.
Pituitary apoplexy in a teenager--case report.
Chao, Chen-Cheng; Lin, Chun-Ju
2014-06-01
Pituitary apoplexy is a rare clinical emergency which results from hemorrhage or infarction in the pituitary gland. We present a 14-year-old girl with pituitary apoplexy and review the literature. Our patient experienced blurred vision, nausea, and headache. Her best-corrected visual acuity was 20/200 and 20/20. Confrontation test visual field testing revealed bitemporal hemianopsia. Brain imaging demonstrated a suprasellar mass. The microscopic endonasal transsphenoidal approach only found 5-10 mL brownish fluid-like material. Pathology confirmed no malignancy. Pituitary apoplexy was diagnosed. Her nausea and headache gradually improved. Six months after operation, her best-corrected visual acuity had improved to 20/30 and 20/20. Although pituitary apoplexy is rare in pediatric patients, prompt evaluation including detailed ophthalmic examination, biochemical evaluation, endocrine workup, and image study are very important. Copyright © 2014 Elsevier Inc. All rights reserved.
Sandu, Irina Crina Anca; Bracci, Susanna; Lobefaro, Mariella; Sandu, Ion
2010-08-01
This article covers a methodology for evaluating the effectiveness of cleaning two Russian icons. The icons belong to a group of five from the same iconographic school, dating from the 16th to 17th centuries. An integrated and complementary approach to varnish and overpaint removal involved microscopic techniques (optical and scanning electron microscopy) and colorimetry (CIE L*a*b* system). The materials and techniques used in these icons have been characterized previously. Cleaning revealed extensive overpainting that had not only dramatically changed the original appearance, but also the meaning and attribution of one of the two icons. The analyses carried out were useful in determining the extent of the overpainting and led to a better assessment of the results and effectiveness of the restoration. (c) 2009 Wiley-Liss, Inc.
Franzen, Angela A; Pigatto, João A T; Abib, Fernando C; Albuquerque, Luciane; Laus, José L
2010-07-01
The purpose of this study was to investigate the effect of age on endothelial morphology and morphometry in cats. The corneal endothelium was studied using a contact specular microscope. A total of 18 cats (Felis catus Linnaeus, 1758) were evaluated in this study. The subjects were divided into three groups of six cats each in function of age: G1 (1 to 3 months old), G2 (5 to 12 months old), and G3 (24 to 40 months old). The examination presented data as endothelial cell density (ECD), average cell area, corneal thickness, polymegathism, and pleomorphism. Results revealed ECD decrease in corneas of normal cats with age, as well as a corresponding increase in endothelial cell area and pleomorphism. The present work suggests that the endothelial parameters evaluated change with advancing age.
NASA Astrophysics Data System (ADS)
Emre, Seker; Mehmet, Ali Kilicarslan; Serdar, Polat; Emre, Ozkir; Suat, Pat
2016-04-01
This study aimed to evaluate the surface roughness and wetting properties of various dental prosthetic materials after different durations of non-thermal atmospheric plasma (NTAP) treatment. One hundred and sixty discs of titanium (Ti) (n:40), cobalt chromium (Co-Cr) (n:40), yttrium stabilized tetragonal zirconia polycrystals (Y-TZP) (n:40) and polymethylmethacrylate (PMMA) (n:40) materials were machined and smoothed with silicon carbide papers. The surface roughness was evaluated in a control group and in groups with different plasma exposure times [1-3-5 s]. The average surface roughness (Ra) and contact angle (CA) measurements were recorded via an atomic force microscope (AFM) and tensiometer, respectively. Surface changes were examined with a scanning electron microscope (SEM). Data were analyzed with two-way analysis of variance (ANOVA) and the Tukey HSD test α=0.05). According to the results, the NTAP surface treatment significantly affected the roughness and wettability properties (P < 0.05). SEM images reveal that more grooves were present in the NTAP groups. With an increase in the NTAP application time, an apparent increment was observed for Ra, except in the PMMA group, and a remarkable reduction in CA was observed in all groups. It is concluded that the NTAP technology could enhance the roughening and wetting performance of various dental materials. supported by the Department of Scientific Research, Eskisehir Osmangazi University, Turkey (No. 201441045)
Microscope-Integrated OCT Feasibility and Utility With the EnFocus System in the DISCOVER Study.
Runkle, Anne; Srivastava, Sunil K; Ehlers, Justis P
2017-03-01
To evaluate the feasibility and utility of a novel microscope-integrated intraoperative optical coherence tomography (OCT) system. The DISCOVER study is an investigational device study evaluating microscope-integrated intraoperative OCT systems for ophthalmic surgery. This report focuses on subjects imaged with the EnFocus prototype system (Leica Microsystems/Bioptigen, Morrisville, NC). OCT was performed at surgeon-directed milestones. Surgeons completed a questionnaire after each case to evaluate the impact of OCT on intraoperative management. Fifty eyes underwent imaging with the EnFocus system. Successful imaging was obtained in 46 of 50 eyes (92%). In eight cases (16%), surgical management was changed based on intraoperative OCT findings. In membrane peeling procedures, intraoperative OCT findings were discordant from the surgeon's initial impression in seven of 20 cases (35%). This study demonstrates the feasibility of microscope-integrated intraoperative OCT using the Bioptigen EnFocus system. Intraoperative OCT may provide surgeons with additional information that may influence surgical decision-making. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:216-222.]. Copyright 2017, SLACK Incorporated.
Ultrastructural effects of silicone oil on the clear crystalline lens of the human eye.
Soliman, Wael; Sharaf, Mohamed; Abdelazeem, Khaled; El-Gamal, Dalia; Nafady, Allam
2018-03-01
To evaluate light and electron microscopic changes of the anterior capsule and its epithelium after clear lens extraction of vitrectomized myopic eyes with silicone oil tamponade. This prospective, controlled, non-randomized, interventional study included 20 anterior lens capsular specimens that were excised during combined clear lens extraction and silicone oil removal from previously vitrectomized highly myopic patients with silicone oil tamponade for previous retinal detachment surgeries. The specimens were examined via light microscopy and electron microscopy and compared with 20 anterior capsule specimens removed during clear lens extraction of non-vitrectomized highly myopic eyes. Light microscopic examination of clear lens anterior capsule specimens of vitrectomized myopic eyes filled with silicone oil showed relatively more flat cells with irregular outline of lens' epithelial cells with wide intercellular spaces, deeply stained nuclei, and multiple intracytoplasmic vacuoles. Scanning electron microscopy revealed collagenous surfaces filled with multiple pits, depressions, and abnormal deposits. Transmission electron microscopy revealed lens epithelial cells with apoptotic changes, many cytoplasmic vacuoles, and filopodia-like protrusions between lens epithelial cells and the capsule. Epithelial proliferation and multilayering were also observed. silicone oil may play a role in the development of apoptotic and histopathological changes in clear lens epithelial cells. Clarity of the lens at the time of silicone oil removal does not indicate an absence of cataractous changes. We found justification of combined clear lens extraction and silicone oil removal or combined phacovitrectomy when silicone oil injection is planned, but further long-term studies with larger patient groups are required.
NASA Astrophysics Data System (ADS)
Pronyaev, Vladimir G.; Capote, Roberto; Trkov, Andrej; Noguere, Gilles; Wallner, Anton
2017-09-01
An IAEA project to update the Neutron Standards is near completion. Traditionally, the Thermal Neutron Constants (TNC) evaluated data by Axton for thermal-neutron scattering, capture and fission on four fissile nuclei and the total nu-bar of 252Cf(sf) are used as input in the combined least-square fit with neutron cross section standards. The evaluation by Axton (1986) was based on a least-square fit of both thermal-spectrum averaged cross sections (Maxwellian data) and microscopic cross sections at 2200 m/s. There is a second Axton evaluation based exclusively on measured microscopic cross sections at 2200 m/s (excluding Maxwellian data). Both evaluations disagree within quoted uncertainties for fission and capture cross sections and total multiplicities of uranium isotopes. There are two factors, which may lead to such difference: Westcott g-factors with estimated 0.2% uncertainties used in the Axton's fit, and deviation of the thermal spectra from Maxwellian shape. To exclude or mitigate the impact of these factors, a new combined GMA fit of standards was undertaken with Axton's TNC evaluation based on 2200 m/s data used as a prior. New microscopic data at the thermal point, available since 1986, were added to the combined fit. Additionally, an independent evaluation of TNC was undertaken using CONRAD code. Both GMA and CONRAD results are consistent within quoted uncertainties. New evaluation shows a small increase of fission and capture thermal cross sections, and a corresponding decrease in evaluated thermal nubar for uranium isotopes and 239Pu.
Dark-field imaging with the scanning transmission x-ray microscope
NASA Astrophysics Data System (ADS)
Morrison, G. R.; Browne, M. T.
1992-01-01
The King's College London scanning transmission x-ray microscope in use on beam line 5U2 at the SRS, SERC Daresbury Laboratory, has been modified to allow dark-field images to be formed using only the x rays scattered by the specimen. Experiments have been performed with a number of different detector geometries, and this has confirmed that the strongest scattering arises from edges or thickness gradients in the specimen. Although the dark-field signal is only a small fraction of the normal transmitted bright-field signal, features can be revealed with high contrast, and it has proved possible to detect the presence of features that are below the resolution limit of the microscope.
Polar nature of stress-induced twin walls in ferroelastic CaTiO3
NASA Astrophysics Data System (ADS)
Yokota, H.; Niki, S.; Haumont, R.; Hicher, P.; Uesu, Y.
2017-08-01
A compressive uniaxial mechanical stress is applied on ferroelastic CaTiO3 (CTO), and a change in the domain structure is observed under a polarization microscope and a second harmonic generation (SHG) microscope. New twin walls (TWs) appear perpendicular to the original TWs under stress. The SHG microscope observations and analyses confirm that this type of stress-induced TWs is polar, similar to the original TWs, and is crystallographically prominent with monoclinic symmetry m. A quantitative estimation of this stress-induced effect reveals that CTO is hard ferroelastic in the sense that the TW movement requires a large stress. A possible application of this phenomenon is discussed.
NASA Astrophysics Data System (ADS)
Mao, Gaojun; Cao, Rui; Guo, Xili; Jiang, Yong; Chen, Jianhong
2017-12-01
The kinetic processes of nucleation and growth of bainite laths in reheated weld metals are observed and analyzed by a combination of a laser confocal scanning microscope and an electron backscattering diffraction with a field emission scanning electron microscope. The results indicate that the surface relief induced by phase transformation is able to reveal the real microstructural morphologies of bainite laths when viewed from various angles. Five nucleation modes and six types of growth behaviors of bainite laths are revealed. The bainite lath growth rates are measured to vary over a wide range, from 2 μm/s to higher than 2000 μm/s. The orientations of the bainite laths within a prior austenite grain are examined and denoted as different variants. On the basis of variant identification, the reason is analyzed for various growth rates which are demonstrated to be affected by (1) the density of the high-angle misorientation in it, (2) the included angle between habit planes of different variants, and (3) the direction of lath growth with respect to the free (polished) surface.
Feldman, Erica; Narayan, Anisha; Taylor, William
2016-01-01
Background : The natural, inflammatory repair processes of an injured intervertebral degenerative disc can propagate further injury and destruction. While there are many different treatment modalities of the pain related to degenerative disc disease, none are actually reparative in nature. Treatment strategies to repair a degenerative disc without inducing a destructive inflammatory milieu have been elusive. Purpose: The purpose of this experiment is to discover the feasibility of reconstructing an injured intervertebral disc using an injected, inert polymer as the foundation for endogenous collagen growth. Study Design: In this ovine model of six subjects in total, we introduce a modality where a large inert polymer, polymethyl methacrylate (PMMA), in conjunction bovine collagen (BC) is injected into the intervertebral disc. Following six months of observation, histologic specimens were evaluated macroscopically and microscopically for evidence of a benefit of the injectable PMMA/BC. Methods: We obtained six merino sheep for this study. Concentric injuries were made to four of their lumbar intervertebral discs. Two of those levels were treated with a percutaneous injection of 0.3 cc of PMMA/BC. The remaining lumbar levels were left untreated and were our controls. After six months, all subjects were sacrificed. Their four levels were extracted and were examined macroscopically and microscopically. Results: All subjects tolerated the lumbar injury and percutaneous injection of PMMA/BC well. After the six month interval, all subjects have demonstrated an intact architecture of their lumbar disc height at the macroscopic and microscopic level. Microscopically, there was no evidence of external migration of the PMMA/BC microspheres, nor was there any evidence of an inflammatory response by its presence. Notably, the PMMA/BC microspheres were well-incorporated into the concentric disc tears and had undergone endogenous collagen formation in its environment. Treatment levels were revealing for maintenance of disc height without evidence of an ongoing degeneration. The controlled levels were revealing for continued disc degeneration with loss of disc height and evolving injury at the level of the concentric tear. Conclusions: This ovine model demonstrates a novel and promising technique for prevention and arrest of lumbar intervertebral disc degeneration. PMID:27630802
Macroscopic characterisations of Web accessibility
NASA Astrophysics Data System (ADS)
Lopes, Rui; Carriço, Luis
2010-12-01
The Web Science framework poses fundamental questions on the analysis of the Web, by focusing on how microscopic properties (e.g. at the level of a Web page or Web site) emerge into macroscopic properties and phenomena. One research topic on the analysis of the Web is Web accessibility evaluation, which centres on understanding how accessible a Web page is for people with disabilities. However, when framing Web accessibility evaluation on Web Science, we have found that existing research stays at the microscopic level. This article presents an experimental study on framing Web accessibility evaluation into Web Science's goals. This study resulted in novel accessibility properties of the Web not found at microscopic levels, as well as of Web accessibility evaluation processes themselves. We observed at large scale some of the empirical knowledge on how accessibility is perceived by designers and developers, such as the disparity of interpretations of accessibility evaluation tools warnings. We also found a direct relation between accessibility quality and Web page complexity. We provide a set of guidelines for designing Web pages, education on Web accessibility, as well as on the computational limits of large-scale Web accessibility evaluations.
Microscope self-calibration based on micro laser line imaging and soft computing algorithms
NASA Astrophysics Data System (ADS)
Apolinar Muñoz Rodríguez, J.
2018-06-01
A technique to perform microscope self-calibration via micro laser line and soft computing algorithms is presented. In this technique, the microscope vision parameters are computed by means of soft computing algorithms based on laser line projection. To implement the self-calibration, a microscope vision system is constructed by means of a CCD camera and a 38 μm laser line. From this arrangement, the microscope vision parameters are represented via Bezier approximation networks, which are accomplished through the laser line position. In this procedure, a genetic algorithm determines the microscope vision parameters by means of laser line imaging. Also, the approximation networks compute the three-dimensional vision by means of the laser line position. Additionally, the soft computing algorithms re-calibrate the vision parameters when the microscope vision system is modified during the vision task. The proposed self-calibration improves accuracy of the traditional microscope calibration, which is accomplished via external references to the microscope system. The capability of the self-calibration based on soft computing algorithms is determined by means of the calibration accuracy and the micro-scale measurement error. This contribution is corroborated by an evaluation based on the accuracy of the traditional microscope calibration.
Atomic Force Microscope for Imaging and Spectroscopy
NASA Technical Reports Server (NTRS)
Pike, W. T.; Hecht, M. H.; Anderson, M. S.; Akiyama, T.; Gautsch, S.; deRooij, N. F.; Staufer, U.; Niedermann, Ph.; Howald, L.; Mueller, D.
2000-01-01
We have developed, built, and tested an atomic force microscope (AFM) for extraterrestrial applications incorporating a micromachined tip array to allow for probe replacement. It is part of a microscopy station originally intended for NASA's 2001 Mars lander to identify the size, distribution, and shape of Martian dust and soil particles. As well as imaging topographically down to nanometer resolution, this instrument can be used to reveal chemical information and perform infrared and Raman spectroscopy at unprecedented resolution.
Albert, Réka; Vásárhelyi, Gábor; Bodó, Gábor; Kenyeres, Annamária; Wolf, Ervin; Papp, Tamás; Terdik, Tünde; Módis, László; Felszeghy, Szabolcs
2012-09-01
One of the most promising applications for the restoration of small or moderately sized focal articular lesions is mosaicplasty (MP). Although recurrent hemarthrosis is a rare complication after MP, recently, various strategies have been designed to find an effective filling material to prevent postoperative bleeding from the donor site. The porous biodegradable polymer Polyactive (PA; a polyethylene glycol terephthalate - polybutylene terephthalate copolymer) represents a promising solution in this respect. A histological evaluation of the longterm PA-filled donor sites obtained from 10 experimental horses was performed. In this study, attention was primarily focused on the bone tissue developed in the plug. A computer-assisted image analysis and quantitative polarized light microscopic measurements of decalcified, longitudinally sectioned, dimethylmethylene blue (DMMB)- and picrosirius red (PS) stained sections revealed that the coverage area of the bone trabecules in the PA-filled donor tunnels was substantially (25%) enlarged compared to the neighboring cancellous bone. For this quantification, identical ROIs (regions of interest) were used and compared. The birefringence retardation values were also measured with a polarized light microscope using monochromatic light. Identical retardation values could be recorded from the bone trabeculae developed in the PA and in the neighboring bone, which indicates that the collagen orientation pattern does not differ significantly among these bone trabecules. Based on our new data, we speculate that PA promotes bone formation, and some of the currently identified degradation products of PA may enhance osteo-conduction and osteoinduction inside the donor canal.
Jeyanthi, Venkadapathi; Velusamy, Palaniyandi
2016-06-01
The aim of this study was to purify, characterize and evaluate the antibacterial activity of bioactive compound against methicillin-resistant Staphylococcus aureus (MRSA). The anti-MRSA compound was produced by a halophilic bacterial strain designated as MHB1. The MHB1 strain exhibited 99 % similarity to Bacillus amyloliquefaciens based on 16S rRNA gene analysis. The culture conditions of Bacillus amyloliquefaciens MHB1 were optimized using nutritional and environmental parameters for enhanced anti-MRSA compound production. The pure bioactive compound was isolated using silica gel column chromatography and Semi-preparative High-performance liquid chromatography (Semi-preparative HPLC). The Thin layer chromatography, Fourier transform infrared spectroscopy and proton NMR ((1)H NMR) analysis indicated the phenolic nature of the compound. The molecular mass of the purified compound was 507 Da as revealed by Liquid chromatography-mass spectrometry (LC-MS) analysis. The compound inhibited the growth of MRSA with minimum inhibitory concentration (MIC) of 62.5 µg mL(-1). MRSA bacteria exposed to 4× MIC of the compound and the cell viability was determined using flow cytometric analysis. Scanning electron microscope and Transmission electron microscope analysis was used to determine the ultrastructural changes in bacteria. This is the first report on isolation of anti-MRSA compound from halophilic B. amyloliquefaciens MHB1 and could act as a promising biocontrol agent.
NASA Astrophysics Data System (ADS)
Yue, Honghao; Lu, Yifan; Deng, Zongquan; Tzou, Hornsen
2018-03-01
Paraboloidal membrane shells of revolution are commonly used as key components for advanced aerospace structures and aviation mechanical systems. Due to their high flexibility and low damping property, active vibration control is of significant importance for these in-orbit membrane structures. To explore the dynamic control behavior of space flexible paraboloidal membrane shells, precision distributed actuation and control effectiveness of free-floating paraboloidal membrane shells with piezoelectric actuators are investigated. Governing equations of the shell structronic system are presented first. Then, distributed control forces and control actions are formulated. A transverse mode shape function of the paraboloidal shell based on the membrane approximation theory and specified boundary condition is assumed in the modal control force analysis. The actuator induced modal control forces on the paraboloidal shell are derived. The expressions of microscopic local modal control forces are obtained by shrinking the actuator area into infinitesimal and the four control components are investigated respectively to predict the spatial microscopic actuation behavior. Geometric parameter (height-radius ratio and shell thickness) effects on the modal actuation behavior are explored when evaluating the micro-control efficiency. Four different cases are discussed and the results reveal the fact that shallow (e.g., antennas/reflectors) and deep (e.g., rocket/missile fairing) paraboloidal shells exhibit totally different modal actuation behaviors due to their curvature differences. Analytical results in this paper can serve as guidelines for optimal actuator placement for vibration control of different paraboloidal structures.
Bouquot, J E; LaMarche, M G
1999-02-01
Previous studies have identified focal areas of alveolar tenderness, elevated mucosal temperature, radiographic abnormality, and increased radioisotope uptake or "hot spots" within the quadrant of pain in most patients with chronic, idiopathic facial pain (phantom pain, atypical facial neuralgia, and atypical facial pain). This retrospective investigation radiographically and microscopically evaluated intramedullary bone in a certain subset of patients with histories of endodontics, extraction, and fixed partial denture placement in an area of "idiopathic" pain. Patients from 12 of the United States were identified through tissue samples, histories, and radiographs submitted to a national biopsy service. Imaging tests, coagulation tests, and microscopic features were reviewed. Of 38 consecutive idiopathic facial pain patients, 32 were women. Approximately 90% of subpontic bone demonstrated either ischemic osteonecrosis (68%), chronic osteomyelitis (21%), or a combination (11%). More than 84% of the patients had abnormal radiographic changes in subpontic bone, and 5 of 9 (56%) patients who underwent radioisotope bone scan revealed hot spots in the region. Of the 14 patients who had laboratory testing for coagulation disorders, 71% were positive for thrombophilia, hypofibrinolysis, or both (normal: 2% to 7%). Ten pain-free patients with abnormal subpontic bone on radiographs were also reviewed. Intraosseous ischemia and chronic inflammation were suggested as a pathoetiologic mechanism for at least some patients with atypical facial pain. These conditions were also offered as an explanation for poor healing of extraction sockets and positive radioisotope scans.
Hahn, Paul; Migacz, Justin; O'Donnell, Rachelle; Day, Shelley; Lee, Annie; Lin, Phoebe; Vann, Robin; Kuo, Anthony; Fekrat, Sharon; Mruthyunjaya, Prithvi; Postel, Eric A; Izatt, Joseph A; Toth, Cynthia A
2013-01-01
The authors have recently developed a high-resolution microscope-integrated spectral domain optical coherence tomography (MIOCT) device designed to enable OCT acquisition simultaneous with surgical maneuvers. The purpose of this report is to describe translation of this device from preclinical testing into human intraoperative imaging. Before human imaging, surgical conditions were fully simulated for extensive preclinical MIOCT evaluation in a custom model eye system. Microscope-integrated spectral domain OCT images were then acquired in normal human volunteers and during vitreoretinal surgery in patients who consented to participate in a prospective institutional review board-approved study. Microscope-integrated spectral domain OCT images were obtained before and at pauses in surgical maneuvers and were compared based on predetermined diagnostic criteria to images obtained with a high-resolution spectral domain research handheld OCT system (HHOCT; Bioptigen, Inc) at the same time point. Cohorts of five consecutive patients were imaged. Successful end points were predefined, including ≥80% correlation in identification of pathology between MIOCT and HHOCT in ≥80% of the patients. Microscope-integrated spectral domain OCT was favorably evaluated by study surgeons and scrub nurses, all of whom responded that they would consider participating in human intraoperative imaging trials. The preclinical evaluation identified significant improvements that were made before MIOCT use during human surgery. The MIOCT transition into clinical human research was smooth. Microscope-integrated spectral domain OCT imaging in normal human volunteers demonstrated high resolution comparable to tabletop scanners. In the operating room, after an initial learning curve, surgeons successfully acquired human macular MIOCT images before and after surgical maneuvers. Microscope-integrated spectral domain OCT imaging confirmed preoperative diagnoses, such as full-thickness macular hole and vitreomacular traction, and demonstrated postsurgical changes in retinal morphology. Two cohorts of five patients were imaged. In the second cohort, the predefined end points were exceeded with ≥80% correlation between microscope-mounted OCT and HHOCT imaging in 100% of the patients. This report describes high-resolution MIOCT imaging using the prototype device in human eyes during vitreoretinal surgery, with successful achievement of predefined end points for imaging. Further refinements and investigations will be directed toward fully integrating MIOCT with vitreoretinal and other ocular surgery to image surgical maneuvers in real time.
Microscopic characterization of Scoparia dulcis Linn.(Scrophulariaceae)
Mishra, Manas Ranjan; Mishra, Ashutosh; Pradhan, Dusmanta Kumar; Behera, Rajani Kanta; Jha, Shivesh; Panda, Ashok Kumar; Choudhary, Punit Ram
2012-01-01
This manuscript covers a detailed pharmacognostic evaluation of Scoparia dulcis Linn. whole plant (Scrophulariaceae), including morphology, microscopy, physicochemical, and phytochemical screening. Microscopy of different plant part was done by performing transverse sections and longitudinal sections, which were identified by the different staining reagents and dyes. Physicochemical constants were done for whole plant; it includes ash value, extractive value and moisture content. Phytochemical screening was done for aqueous and methanolic extract in maceration and soxhletion, results revealed the presence of alkaloids, glycosides, carbohydrates, phenolic compound, flavonoids, saponins, proteins, and amino acids. These study includes parameters to establish the authenticity of S. dulcis and can possibly help to differentiate the drug from its other species. PMID:23929991
Microscopic characterization of Scoparia dulcis Linn.(Scrophulariaceae).
Mishra, Manas Ranjan; Mishra, Ashutosh; Pradhan, Dusmanta Kumar; Behera, Rajani Kanta; Jha, Shivesh; Panda, Ashok Kumar; Choudhary, Punit Ram
2012-07-01
This manuscript covers a detailed pharmacognostic evaluation of Scoparia dulcis Linn. whole plant (Scrophulariaceae), including morphology, microscopy, physicochemical, and phytochemical screening. Microscopy of different plant part was done by performing transverse sections and longitudinal sections, which were identified by the different staining reagents and dyes. Physicochemical constants were done for whole plant; it includes ash value, extractive value and moisture content. Phytochemical screening was done for aqueous and methanolic extract in maceration and soxhletion, results revealed the presence of alkaloids, glycosides, carbohydrates, phenolic compound, flavonoids, saponins, proteins, and amino acids. These study includes parameters to establish the authenticity of S. dulcis and can possibly help to differentiate the drug from its other species.
Kumagai, Kazuhiro; Sekiguchi, Takashi
2009-03-01
To understand secondary electron (SE) image formation with in-lens and out-lens detector in low-voltage scanning electron microscopy (LV-SEM), we have evaluated SE signals of an in-lens and an out-lens detector in LV-SEM. From the energy distribution spectra of SEs with various boosting voltages of the immersion lens system, we revealed that the electrostatic field of the immersion lens mainly collects electrons with energy lower than 40eV, acting as a low-pass filter. This effect is also observed as a contrast change in LV-SEM images taken by in-lens and out-lens detectors.
NASA Astrophysics Data System (ADS)
Zhao, Junjie; Dong, Xiaochen; Bian, Mengmeng; Zhao, Junfeng; Zhang, Yao; Sun, Yue; Chen, JianHua; Wang, XuHong
2014-09-01
Hydroxyapatite (HAP), fluorapatite (Fap) and chlorapatite (Clap) were prepared by solution combustion method with further annealing at 800 °C. The characterization and structural features of the synthesized powders were evaluated by the powder X-ray diffraction (XRD, Fourier transform infrared spectroscopy (FT-IR), scanning electron microscope (SEM) and transmission electron microscopy (TEM) techniques. Characterization results from XRD and Rietveld analysis revealed that OH- in the HAP lattice were gradually substituted with the increase of F- and Cl- content and totally substituted at the molar concentration of 0.28 and 0.6, respectively. The results from FI-IR have also confirmed the incorporation of substituted anions in the apatite structure.
Chandrappa, Mahesh Martur; Meharwade, Prasanna Mahadevasa; Srinivasan, Raghu; Bhandary, Shreetha; Nasreen, Farhat
2016-01-01
Aim: The objective of this study was to evaluate the effectiveness of 5.25% sodium hypochlorite (NaOCl), 2% chlorhexidine (CHX), and 2% peracetic acid (PAA) in disinfecting Resilon cones and to evaluate topographical changes microscopically under scanning electron microscope (SEM) after rapid chemical disinfection. Materials and Methods: Resilon cones were disinfected in an ultraviolet (UV) light chamber for 20 min and contaminated by immersing in a microbial suspension of Enterococcus faecalis for 30 min. The contaminated cones were then immersed in the 5.25% NaOCl, 2% CHX, and 2% PAA for 1 min, 5 min, and 10 min, separately. The cones were then incubated at 37°C in thioglycollate broth for 7 days and examined for turbidity. The samples showing turbidity were subcultured on blood agar and incubated at 37°C for 48 h. Gram staining was done to confirm that the cultured bacteria were E. faecalis. Surface changes of disinfected Resilon cones were evaluated under SEM. Statistical Analysis Used: The data were analyzed statistically using Kruskal-Wallis, analysis of variance (ANOVA), and Mann–Whitney U-test. Result: In eliminating E. faecalis, 5.25% NaOCl was most effective followed by 2% PAA and 2% CHX. Topographic examination of tested Resilon cones revealed some surface deposits after disinfection with 5.25% NaOCl and 2% CHX, whereas 2% PAA caused surface erosion. Conclusion: In disinfecting Resilon cones, 5.25% NaOCl is most effective followed by 2% PAA and 2% CHX. PMID:27099418
eeDAP: An Evaluation Environment for Digital and Analog Pathology
Gallas, Brandon D.; Cheng, Wei-Chung; Gavrielides, Marios A.; Ivansky, Adam; Keay, Tyler; Wunderlich, Adam; Hipp, Jason; Hewitt, Stephen M.
2017-01-01
Purpose The purpose of this work is to present a platform for designing and executing studies that compare pathologists interpreting histopathology of whole slide images (WSI) on a computer display to pathologists interpreting glass slides on an optical microscope. Methods Here we present eeDAP, an evaluation environment for digital and analog pathology. The key element in eeDAP is the registration of the WSI to the glass slide. Registration is accomplished through computer control of the microscope stage and a camera mounted on the microscope that acquires images of the real time microscope view. Registration allows for the evaluation of the same regions of interest (ROIs) in both domains. This can reduce or eliminate disagreements that arise from pathologists interpreting different areas and focuses the comparison on image quality. Results We reduced the pathologist interpretation area from an entire glass slide (≈10–30 mm)2 to small ROIs <(50 um)2. We also made possible the evaluation of individual cells. Conclusions We summarize eeDAP’s software and hardware and provide calculations and corresponding images of the microscope field of view and the ROIs extracted from the WSIs. These calculations help provide a sense of eeDAP’s functionality and operating principles, while the images provide a sense of the look and feel of studies that can be conducted in the digital and analog domains. The eeDAP software can be downloaded from code.google.com (project: eeDAP) as Matlab source or as a precompiled stand-alone license-free application. PMID:28845079
Baghaie, Ahmadreza; Pahlavan Tafti, Ahmad; Owen, Heather A; D'Souza, Roshan M; Yu, Zeyun
2017-01-01
Scanning Electron Microscope (SEM) as one of the major research and industrial equipment for imaging of micro-scale samples and surfaces has gained extensive attention from its emerge. However, the acquired micrographs still remain two-dimensional (2D). In the current work a novel and highly accurate approach is proposed to recover the hidden third-dimension by use of multi-view image acquisition of the microscopic samples combined with pre/post-processing steps including sparse feature-based stereo rectification, nonlocal-based optical flow estimation for dense matching and finally depth estimation. Employing the proposed approach, three-dimensional (3D) reconstructions of highly complex microscopic samples were achieved to facilitate the interpretation of topology and geometry of surface/shape attributes of the samples. As a byproduct of the proposed approach, high-definition 3D printed models of the samples can be generated as a tangible means of physical understanding. Extensive comparisons with the state-of-the-art reveal the strength and superiority of the proposed method in uncovering the details of the highly complex microscopic samples.
Pashmakova, Medora B; Piccione, Julie; Bishop, Micah A; Nelson, Whitney R; Lawhon, Sara D
2017-05-01
OBJECTIVE To evaluate the agreement between results of microscopic examination and bacterial culture of bile samples from dogs and cats with hepatobiliary disease for detection of bactibilia. DESIGN Cross-sectional study. ANIMALS 31 dogs and 21 cats with hepatobiliary disease for which subsequent microscopic examination and bacterial culture of bile samples was performed from 2004 through 2014. PROCEDURES Electronic medical records of included dogs and cats were reviewed to extract data regarding diagnosis, antimicrobials administered, and results of microscopic examination and bacterial culture of bile samples. Agreement between these 2 diagnostic tests was assessed by calculation of the Cohen κ value. RESULTS 17 (33%) dogs and cats had bactibilia identified by microscopic examination of bile samples, and 11 (21%) had bactibilia identified via bacterial culture. Agreement between these 2 tests was substantial (percentage agreement [positive and negative results], 85%; κ = 0.62; 95% confidence interval, 0.38 to 0.89) and improved to almost perfect when calculated for only animals that received no antimicrobials within 24 hours prior to sample collection (percentage agreement, 94%; κ = 0.84; 95% confidence interval, 0.61 to 1.00). CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that agreement between microscopic examination and bacterial culture of bile samples for detection of bactibilia is optimized when dogs and cats are not receiving antimicrobials at the time of sample collection. Concurrent bacterial culture and microscopic examination of bile samples are recommended for all cats and dogs evaluated for hepatobiliary disease.
DOT National Transportation Integrated Search
2004-01-01
Microscopic traffic simulation models have been widely accepted and applied in transportation engineering and planning practice for the past decades because simulation is cost-effective, safe, and fast. To achieve high fidelity and credibility for a ...
DOT National Transportation Integrated Search
2006-01-01
A previous study developed a procedure for microscopic simulation model calibration and validation and evaluated the procedure via two relatively simple case studies using three microscopic simulation models. Results showed that default parameters we...
A pragmatic guide to multiphoton microscope design
Young, Michael D.; Field, Jeffrey J.; Sheetz, Kraig E.; Bartels, Randy A.; Squier, Jeff
2016-01-01
Multiphoton microscopy has emerged as a ubiquitous tool for studying microscopic structure and function across a broad range of disciplines. As such, the intent of this paper is to present a comprehensive resource for the construction and performance evaluation of a multiphoton microscope that will be understandable to the broad range of scientific fields that presently exploit, or wish to begin exploiting, this powerful technology. With this in mind, we have developed a guide to aid in the design of a multiphoton microscope. We discuss source selection, optical management of dispersion, image-relay systems with scan optics, objective-lens selection, single-element light-collection theory, photon-counting detection, image rendering, and finally, an illustrated guide for building an example microscope. PMID:27182429
NASA Astrophysics Data System (ADS)
Schmit, Joanna; Novak, Matt; Bui, Son
2015-09-01
3D microscopes based on white light interference (WLI) provide precise measurement for the topography of engineering surfaces. However, the display of an object in its true colors as observed under white illumination is often desired; this traditionally has presented a challenge for WLI-based microscopes. Such 3D color display is appealing to the eye and great for presentations, and also provides fast evaluation of certain characteristics like defects, delamination, or deposition of different materials. Determination of color as observed by interferometric objectives is not straightforward; we will present how color imaging capabilities similar to an ordinary microscope can be obtained in interference microscopes based on WLI and we will give measurement and imaging examples of a few industrial samples.
Miyai, K; Abraham, J L; Linthicum, D S; Wagner, R M
1976-10-01
Several methods of tissue preparation and different modes of operation of the scanning electron microscope were used to study the ultrastructure of rat liver. Rat livers were perfusion fixed with buffered 2 per cent paraformaldehyde or a mixture of 1.5 per cent paraformaldehyde and 1 per cent glutaraldehyde and processed as follows. Tissue blocks were postfixed in buffered 2 per cent osmium tetroxide followed sequentially by the ligand-mediated osmium binding technique, dehydration and cryofracture in ethanol, and critical point drying. They were then examined without metal coating in the scanning electron microscope operating in the secondary electron and backscattered electron modes. Fifty-micrometer sections were cut with a tissue sectioner, stained with lead citrate, postfixed with osmium, dehydrated, critical point dried, and examined in the secondary electron and back-scattered electron modes. Frozen sections (0.25 to 0.75 mum. thick) were cut by the method of Tokuyasu (Toluyasu KT: J Cell Biol 57:551, 1973) and their scanning transmission electron microscope images were examined either with a scanning transmission electron microscope detector or with a conversion stub using the secondary electron detector. Secondary electron images of the liver prepared by ligand-mediated osmium binding and subsequent cryofracture revealed such intracellular structures as cisternae of the endoplasmic reticulum, lysosomes, mitochondria, lipid droplets, nucleolus and nuclear chromatin, as well as the usual surface morphology, Lipocytes in the perisinusoidal space were readily identified. Backscattered electron images. Unembedded frozen sections had little drying artifact and were virtually free of freezing damage. The scanning transmission electron microscope image revealed those organelles visualized by the secondary electron mode in the ligand-mediated osmium binding-treated tissue.
Vaughan, Alicia F.; Johnson, Jeffrey R.; Herkenhoff, Kenneth E.; Sullivan, Robert; Landis, Geoffrey A.; Goetz, Walter; Madsen, Morten B.
2010-01-01
This work describes dust deposits on the Spirit Rover over 2000 sols through examination of Pancam and Microscopic Imager observations of specific locations on the rover body, including portions of the solar array, Pancam and Mini-TES calibration targets, and the magnets. This data set reveals the three "cleaning events" experienced by Spirit to date, the spectral properties of dust, and the tendency of dust particles to form aggregates 100 um and larger.
NASA Astrophysics Data System (ADS)
Hameed, M. Shahul; Princice, J. Joseph; Babu, N. Ramesh; Zahirullah, S. Syed; Deshmukh, Sampat G.; Arunachalam, A.
2018-05-01
Transparent conductive Sn doped ZnO nanorods have been deposited at various doping level by spray pyrolysis technique on glass substrate. The structural, surface morphological and optical properties of these films have been investigated with the help of X-ray diffraction (XRD), scanning electron microscope (SEM), atomic force microscope (AFM) and UV-Vis spectrophotometer respectively. XRD patterns revealed a successful high quality growth of single crystal ZnO nanorods with hexagonal wurtzite structure having (002) preferred orientation. The scanning electron microscope (SEM) image of the prepared films exposed the uniform distribution of Sn doped ZnO nanorod shaped grains. All these films were highly transparent in the visible region with average transmittance of 90%.
NASA Astrophysics Data System (ADS)
Zhang, Shuai; Zhang, Bo; He, Jinliang
2014-06-01
Corona discharge is one of the major design factors for extra-high voltage and ultra-high voltage DC/AC transmission lines. Under different voltages, corona discharge reveals different characteristics. This paper aims at investigating DC and AC coronas on the microscopic scale. To obtain the specific characteristics of DC and AC coronas, a new measurement approach that utilizes a coaxial wire-cylinder corona cage is designed in this paper, and wires of different diameters are used in the experiment. Based on the measurements, the respective microscopic characteristics of DC and AC coronas are analyzed and compared. With differences in characteristics between DC and AC coronas proposed, this study provides useful insights into DC/AC corona discharges on transmission line applications.
Collier, Larissa; Dunham, Stacey; Braun, Mark W; O'Loughlin, Valerie Dean
2012-01-01
Many studies that evaluate the introduction of technology in the classroom focus on student performance and student evaluations. This study focuses on instructor evaluation of the introduction of virtual microscopy into an undergraduate anatomy class. Semi-structured interviews were conducted with graduate teaching assistants (TA) and analyzed through qualitative methods. This analysis showed that the teaching assistants found the virtual microscope to be an advantageous change in the classroom. They cite the ease of use of the virtual microscope, access to histology outside of designated laboratory time, and increasing student collaboration in class as the primary advantages. The teaching assistants also discuss principal areas where the use of the virtual microscope can be improved from a pedagogical standpoint, including requiring students to spend more time working on histology in class. Copyright © 2011 American Association of Anatomists.
Ueberrueck, T; Meyer, L; Zippel, R; Nestler, G; Wahlers, T; Gastinger, I
2005-02-01
To investigate the intraluminal and extraluminal healing behaviour of a new metallic silver coated, gelatine impregnated vascular graft. Comparative animal experimental investigation with randomisation of the animals to control and experimental groups. 24 pigs were assigned to two control and two experimental groups. The prostheses were interposed in the pigs' infrarenal aorta. For the evaluation, macroscopic, histological and immunohistochemical criteria were applied. The macroscopic evaluation after explantation of the prosthesis revealed similar healing characteristics in the control and experimental groups. The microscopic determination of neo-intimal thickness showed no significant differences between the groups; nor did the immunohistochemical investigations show any significant difference between the control group and the silver-coated prosthesis group. No disadvantage of the silver coating in terms of healing and graft patency was found. A possible advantage in terms of the antibacterial effect of the silver coating must be investigated in the clinical setting.
NASA Astrophysics Data System (ADS)
Kiani, Mohammad Amin; Ahmadi, Seyed Javad; Outokesh, Mohammad; Adeli, Ruhollah; Mohammadi, Aghil
2017-12-01
In this research, the characteristics of the prepared samples in epoxy matrix by means of X-ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDS), as well as scanning electron microscope (SEM) are evaluated. Meanwhile, the obtained mechanical properties of the specimen are investigated. Thermogravimetric analysis (TGA) is also employed to evaluate the thermal degradation of manufactured nanocomposites. The thermal neutron absorption properties of nanocomposites containing 3 wt% of montmorillonite nanoclay (closite30B) have been studied experimentally, using an Am-Be point source. Mechanical tests reveal that the higher B4C concentrations, the more tensile strengths, but lower Young's modulus in all samples under consideration. TGA analysis also shows that thermal stability of the nanocomposite, increases in presence of B4C. Finally, neutron absorption analysis shows that increasing the B4C concentration leads to a nonlinearly build-up of neutron absorption cross section.
Electromagnetic nondestructive evaluation of tempering process in AISI D2 tool steel
NASA Astrophysics Data System (ADS)
Kahrobaee, Saeed; Kashefi, Mehrdad
2015-05-01
The present paper investigates the potential of using eddy current technique as a reliable nondestructive tool to detect microstructural changes during the different stages of tempering treatment in AISI D2 tool steel. Five stages occur in tempering of the steel: precipitation of ɛ carbides, formation of cementite, retained austenite decomposition, secondary hardening effect and spheroidization of carbides. These stages were characterized by destructive methods, including dilatometry, differential scanning calorimetry, X-ray diffraction, scanning electron microscopic observations, and hardness measurements. The microstructural changes alter the electrical resistivity/magnetic saturation, which, in turn, influence the eddy current signals. Two EC parameters, induced voltage sensed by pickup coil and impedance point detected by excitation coil, were evaluated as a function of tempering temperature to characterize the microstructural features, nondestructively. The study revealed that a good correlation exists between the EC parameters and the microstructural changes.
Bi2Te3 thin hexagonal nanoplatelets: Synthesis and its characterization studies
NASA Astrophysics Data System (ADS)
Vinoth, S.; Balaganapathi, T.; KaniAmuthan, B.; Arun, T.; Muthuselvam, I. Panneer; Chou, Fang-Cheng; Thilakan, P.
2017-08-01
Solvothermal synthesis and optimization of pure Bismuth telluride (Bi2Te3) hexagonal nanoplatelets was carried out from Bismuth Oxide (Bi2O3) and Tellurium dioxide (TeO2). XRD measurements revealed a sensitive change in crystallization behaviour in correlation with variation in Te/Bi stoichiometry identified through the exchange in intensities between (10 10 ̅) and (110) peaks. Further, Energy Dispersive X-ray (EDAX) analysis revealed the variation in Te/Bi ratio with respect to autoclave temperature. Field emission scanning electron Microscope (FESEM) and the high resolution transmission electron Microscope (HRTEM) studies show the complete growth of hexagonal nanoplatelets at 200 °C. Confocal Micro-Raman measurements revealed the occurrence of symmetry breaking in the synthesized hexagonal nanoplatelets. The electrical conductivity and the activation energy were recorded as 6.01×10-3 S/m and 0.042 eV respectively. Highest maximum absolute value of Seebeck coefficient of -355 μV/K was obtained for the hexagonal nanoplatelets.
Wang, Ye; He, Honghui; Chang, Jintao; Zeng, Nan; Liu, Shaoxiong; Li, Migao; Ma, Hui
2015-12-01
Polarized light imaging can provide rich microstructural information of samples, and has been applied to the detections of various abnormal tissues. In this paper, we report a polarized light microscope based on Mueller matrix imaging by adding the polarization state generator and analyzer (PSG and PSA) to a commercial transmission optical microscope. The maximum errors for the absolute values of Mueller matrix elements are reduced to 0.01 after calibration. This Mueller matrix microscope has been used to examine human cervical and liver cancerous tissues with fibrosis. Images of the transformed Mueller matrix parameters provide quantitative assessment on the characteristic features of the pathological tissues. Contrast mechanism of the experimental results are backed up by Monte Carlo simulations based on the sphere-cylinder birefringence model, which reveal the relationship between the pathological features in the cancerous tissues at the cellular level and the polarization parameters. Both the experimental and simulated data indicate that the microscopic transformed Mueller matrix parameters can distinguish the breaking down of birefringent normal tissues for cervical cancer, or the formation of birefringent surrounding structures accompanying the inflammatory reaction for liver cancer. With its simple structure, fast measurement and high precision, polarized light microscope based on Mueller matrix shows a good diagnosis application prospect. Copyright © 2015 Elsevier Ltd. All rights reserved.
Nishiyama, Hidetoshi; Suga, Mitsuo; Ogura, Toshihiko; Maruyama, Yuusuke; Koizumi, Mitsuru; Mio, Kazuhiro; Kitamura, Shinichi; Sato, Chikara
2010-03-01
Direct observation of subcellular structures and their characterization is essential for understanding their physiological functions. To observe them in open environment, we have developed an inverted scanning electron microscope with a detachable, open-culture dish, capable of 8 nm resolution, and combined with a fluorescence microscope quasi-simultaneously observing the same area from the top. For scanning electron microscopy from the bottom, a silicon nitride film window in the base of the dish maintains a vacuum between electron gun and open sample dish while allowing electrons to pass through. Electrons are backscattered from the sample and captured by a detector under the dish. Cells cultured on the open dish can be externally manipulated under optical microscopy, fixed, and observed using scanning electron microscopy. Once fine structures have been revealed by scanning electron microscopy, their component proteins may be identified by comparison with separately prepared fluorescence-labeled optical microscopic images of the candidate proteins, with their heavy-metal-labeled or stained ASEM images. Furthermore, cell nuclei in a tissue block stained with platinum-blue were successfully observed without thin-sectioning, which suggests the applicability of this inverted scanning electron microscope to cancer diagnosis. This microscope visualizes mesoscopic-scale structures, and is also applicable to non-bioscience fields including polymer chemistry. (c) 2010 Elsevier Inc. All rights reserved.
Warthin tumor: a curious entity--case reports and review of literature.
Faur, Alexandra; Lazăr, Elena; Cornianu, Mărioara; Dema, Alis; Vidita, Camelia Gurban; Găluşcan, Atena
2009-01-01
Warthin tumor was first described in the American literature, by Aldred Warthin, in 1929, the pathologist who named this tumor papillary cystadenoma lymphomatosum, but since than it was also knew as adenolymphoma, cystadenolymphoma, and Warthin tumor. Because of its microscopically appearance and unknown origin, this tumor entity is still fascinating head and neck surgeons and pathologist. We evaluate the histopathological aspect of Warthin tumors using Hematoxylin-Eosin stain, and immunohistochemical and histological techniques. We reviewed the medical record of patients with salivary gland tumors diagnosed at County Hospital of Timisoara from 2002-2008. In six years, 22 cases with Warthin tumor were diagnosed and among them 17 men and five women, with average age 58.47. The analysis showed that 77.27% of Warthin tumors occurred in men, and the main histopathological aspect was with 50% epithelial component. The stromal component showed a prominent B-cell population by staining with CD20, and histological techniques for mucin were positive, and reticulin fibers were revealed while using Gordon-Sweets stain. The standard and the histological and immunohistochemical techniques highlighted the complex and variable microscopical appearance of Warthin tumor that the pathologist should consider when a diagnosis for this tumor is to be considered.
NASA Astrophysics Data System (ADS)
Paulkumar, Kanniah; Gnanajobitha, Gnanadhas; Vanaja, Mahendran; Pavunraj, Manickam; Annadurai, Gurusamy
2017-09-01
Synthesis of nanoparticles and nanocomposites using green route is a major focus of modern nanotechnology. Herein we demonstrate the synthesis of silver nanoparticle and silver based chitosan bionanocomposite using the stem extract of Saccharum officinarum. The absorbance peak at 460 nm in the UV-Vis spectrum reveals the synthesis of silver nanoparticles using the stem extract of Saccharum officinarum. The size of the synthesized silver nanoparticle was in the range of 10-60 nm obtained from transmission electron microscope (TEM) analysis. The presence of silver nanoparticles on the chitosan suspension was identified by scanning electron microscope (SEM) and energy dispersive x-ray spectroscopy (EDS). The presence of possible functional group involved in the reduction of silver metal ions into silver nanoparticles was identified by Fourier transform infrared spectroscopy (FTIR) analysis. The antibacterial activity of the synthesized silver based chitosan bionanocomposite was evaluated against Bacillus subtilis (MTCC 3053), Klebsiella planticola (MTCC 2277), Streptococcus faecalis (ATCC 8043), Pseudomonas aeruginosa (ATCC 9027) and Escherichia coli (ATCC 8739). The antibacterial activity of silver based chitosan bionanocomposite has remarkable scope in medicine, food packaging, textile and pharmaceuticals.
Paulkumar, Kanniah; Gnanajobitha, Gnanadhas; Vanaja, Mahendran; Rajeshkumar, Shanmugam; Malarkodi, Chelladurai; Pandian, Kannaiyan; Annadurai, Gurusamy
2014-01-01
Utilization of biological materials in synthesis of nanoparticles is one of the hottest topics in modern nanoscience and nanotechnology. In the present investigation, the silver nanoparticles were synthesized by using the leaf and stem extract of Piper nigrum. The synthesized nanoparticle was characterized by UV-vis spectroscopy, X-ray diffraction (XRD), scanning electron microscope (SEM), transmission electron microscope (TEM), energy dispersive X-ray analysis (EDAX), and Fourier Transform Infrared Spectroscopy (FTIR). The observation of the peak at 460 nm in the UV-vis spectra for leaf- and stem-synthesized silver nanoparticles reveals the reduction of silver metal ions into silver nanoparticles. Further, XRD analysis has been carried out to confirm the crystalline nature of the synthesized silver nanoparticles. The TEM images show that the leaf- and stem-synthesized silver nanoparticles were within the size of about 7-50 nm and 9-30 nm, respectively. The FTIR analysis was performed to identify the possible functional groups involved in the synthesis of silver nanoparticles. Further, the antibacterial activity of the green-synthesized silver nanoparticles was examined against agricultural plant pathogens. The antibacterial property of silver nanoparticles is a beneficial application in the field of agricultural nanotechnology.
NASA Astrophysics Data System (ADS)
Deng, Yun; Hajilou, Tarlan; Barnoush, Afrooz
2017-06-01
To evaluate the hydrogen (H)-induced embrittlement in iron aluminium intermetallics, especially the one with stoichiometric composition of 50 at.% Al, a novel in situ micro-cantilever bending test was applied within an environmental scanning electron microscope (ESEM), which provides both a full process monitoring and a clean, in situ H-charging condition. Two sets of cantilevers were analysed in this work: one set of un-notched cantilevers, and the other set with focused ion beam-milled notch laying on two crystallographic planes: (010) and (110). The cantilevers were tested under two environmental conditions: vacuum (approximately 5 × 10-4 Pa) and ESEM (450 Pa water vapour). Crack initiation at stress-concentrated locations and propagation to cause catastrophic failure were observed when cantilevers were tested in the presence of H; while no cracking occurred when tested in vacuum. Both the bending strength for un-notched beams and the fracture toughness for notched beams were reduced under H exposure. The hydrogen embrittlement (HE) susceptibility was found to be orientation dependent: the (010) crystallographic plane was more fragile to HE than the (110) plane. This article is part of the themed issue 'The challenges of hydrogen and metals'.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCall, Keisha C.; Humm, John L.; Bartlett, Rachel
Purpose: The behavior of copper-64-diacetyl-bis(N(4)-methylthiosemicarbazone) ({sup 64}Cu-ATSM) in hypoxic tumors was examined through a combination of in vivo dynamic positron emission tomography (PET) and ex vivo autoradiographic and histologic evaluation using a xenograft model of head-and-neck squamous cell carcinoma. Methods and Materials: {sup 64}Cu-ATSM was administered during dynamic PET imaging, and temporal changes in {sup 64}Cu-ATSM distribution within tumors were evaluated for at least 1 hour and up to 18 hours. Animals were sacrificed at either 1 hour (cohort A) or after 18 hours (cohort B) postinjection of radiotracer and autoradiography performed. Ex vivo analysis of microenvironment subregions was conductedmore » by immunohistochemical staining for markers of hypoxia (pimonidazole hydrochloride) and blood flow (Hoechst-33342). Results: Kinetic analysis revealed rapid uptake of radiotracer by tumors. The net influx (K{sub i}) constant was 12-fold that of muscle, whereas the distribution volume (V{sub d}) was 5-fold. PET images showed large tumor-to-muscle ratios, which continually increased over the entire 18-hour course of imaging. However, no spatial changes in {sup 64}Cu-ATSM distribution occurred in PET imaging at 20 minutes postinjection. Microscopic intratumoral distribution of {sup 64}Cu-ATSM and pimonidazole were not correlated at 1 hour or after 18 hours postinjection, nor was {sup 64}Cu-ATSM and Hoechst-33342. Conclusions: The oxygen partial pressures at which {sup 64}Cu-ATSM and pimonidazole are reduced and bound in cells are theorized to be distinct and separable. However, this study demonstrated that microscopic distributions of these tracers within tumors are independent. Researchers have shown {sup 64}Cu-ATSM uptake to be specific to malignant expression, and this work has also demonstrated clear tumor targeting by the radiotracer.« less
A New Method to Develop Human Dental Pulp Cells and Platelet-rich Fibrin Complex.
He, Xuan; Chen, Wen-Xia; Ban, Guifei; Wei, Wei; Zhou, Jun; Chen, Wen-Jin; Li, Xian-Yu
2016-11-01
Platelet-rich fibrin (PRF) has been used as a scaffold material in various tissue regeneration studies. In the previous methods to combine seed cells with PRF, the structure of PRF was damaged, and the manipulation time in vitro was also increased. The objective of this in vitro study was to explore an appropriate method to develop a PRF-human dental pulp cell (hDPC) complex to maintain PRF structure integrity and to find out the most efficient part of PRF. The PRF-hDPC complex was developed at 3 different time points during PRF preparation: (1) the before centrifugation (BC) group, the hDPC suspension was added to the venous blood before blood centrifugation; (2) the immediately after centrifugation (IAC) group, the hDPC suspension was added immediately after blood centrifugation; (3) the after centrifugation (AC) group, the hDPC suspension was added 10 minutes after blood centrifugation; and (4) the control group, PRF without hDPC suspension. The prepared PRF-hDPC complexes were cultured for 7 days. The samples were fixed for histologic, immunohistochemistry, and scanning electron microscopic evaluation. Real-time polymerase chain reaction was performed to evaluate messenger RNA expression of alkaline phosphatase and dentin sialophosphoprotein. Enzyme-linked immunosorbent assay quantification for growth factors was performed within the different parts of the PRF. Histologic, immunohistochemistry, and scanning electron microscopic results revealed that hDPCs were only found in the BC group and exhibited favorable proliferation. Real-time polymerase chain reaction revealed that alkaline phosphatase and dentin sialophosphoprotein expression increased in the cultured PRF-hDPC complex. The lower part of the PRF released the maximum quantity of growth factors. Our new method to develop a PRF-hDPCs complex maintained PRF structure integrity. The hDPCs were distributed in the buffy coat, which might be the most efficient part of PRF. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Laterally modulated excitation microscopy: improvement of resolution by using a diffraction grating
NASA Astrophysics Data System (ADS)
Heintzmann, Rainer; Cremer, Christoph G.
1999-01-01
High spatial frequencies in the illuminating light of microscopes lead to a shift of the object spatial frequencies detectable through the objective lens. If a suitable procedure is found for evaluation of the measured data, a microscopic image with a higher resolution than under flat illumination can be obtained. A simple method for generation of a laterally modulated illumination pattern is discussed here. A specially constructed diffraction grating was inserted in the illumination beam path at the conjugate object plane (position of the adjustable aperture) and projected through the objective into the object. Microscopic beads were imaged with this method and evaluated with an algorithm based on the structure of the Fourier space. The results indicate an improvement of resolution.
Evaluation and purchase of confocal microscopes: numerous factors to consider.
Zucker, Robert M; Chua, Michael
2010-10-01
The purchase of a confocal microscope is a difficult decision. Many factors need to be considered, which include hardware, software, company, support, service, and price. These issues are discussed to help guide the purchasing process. © 2010 by John Wiley & Sons, Inc.
Harris, T; Leaven, T; Heidger, P; Kreiter, C; Duncan, J; Dick, F
2001-02-01
Emerging technology now exists to digitize a gigabyte of information from a glass slide, save it in a highly compressed file format, and deliver it over the web. By accessing these images with a standard web browser and viewer plug-in, a computer can emulate a real microscope and glass slide. Using this new technology, the immediate aims of our project were to digitize the glass slides from urinary tract, male genital, and endocrine units and implement them in the Spring 2000 Histology course at the University of Iowa, and to carry out a formative evaluation of the virtual slides of these three units in a side-by-side comparison with the regular microscope laboratory. The methods and results of this paper will describe the technology employed to create the virtual slides, and the formative evaluation carried out in the course. Anat Rec (New Anat) 265:10-14, 2001. Copyright 2001 Wiley-Liss, Inc.
Schollaen, Karina; Heinrich, Ingo; Helle, Gerhard
2014-02-01
UV-laser-based microscopic systems were utilized to dissect and sample organic tissue for stable isotope measurements from thin wood cross-sections. We tested UV-laser-based microscopic tissue dissection in practice for high-resolution isotopic analyses (δ(13) C/δ(18) O) on thin cross-sections from different tree species. The method allows serial isolation of tissue of any shape and from millimetre down to micrometre scales. On-screen pre-defined areas of interest were automatically dissected and collected for mass spectrometric analysis. Three examples of high-resolution isotopic analyses revealed that: in comparison to δ(13) C of xylem cells, woody ray parenchyma of deciduous trees have the same year-to-year variability, but reveal offsets that are opposite in sign depending on whether wholewood or cellulose is considered; high-resolution tree-ring δ(18) O profiles of Indonesian teak reflect monsoonal rainfall patterns and are sensitive to rainfall extremes caused by ENSO; and seasonal moisture signals in intra-tree-ring δ(18) O of white pine are weighted by nonlinear intra-annual growth dynamics. The applications demonstrate that the use of UV-laser-based microscopic dissection allows for sampling plant tissue at ultrahigh resolution and unprecedented precision. This new technique facilitates sampling for stable isotope analysis of anatomical plant traits like combined tree eco-physiological, wood anatomical and dendroclimatological studies. © 2013 The Authors. New Phytologist © 2013 New Phytologist Trust.
Razak, Adam A; Horridge, Michelle; Connolly, Daniel J; Warren, Daniel J; Mirza, Showkat; Muraleedharan, Vakkat; Sinha, Saurabh
2013-02-01
Pituitary surgery has seen a recent shift from a microscopic to an endoscopic trans-sphenoidal approach. We present our early experience with endoscopic surgery and compare the outcome with our recent microscopic experience. From January 2008 until present time, 80 consecutive patients underwent trans-sphenoidal pituitary surgery in our institution. Until September 2009, all patients had a microscopic trans-septal approach. After this time, the patients underwent endoscopic trans-sphenoidal surgery. All patients underwent pre- and post-operative MRI and full endocrinological evaluation. Data was collected prospectively including tumour volume, endocrine function, visual function, length of stay and complications. There were 40 patients in each group. In the microscopic group, there were 26 non-functioning tumours and 14 functioning tumours. In the endoscopic group, there were 24 non-functioning and 16 functioning tumours. There were significantly better results in terms of tumour resection (p = 0.002) and remission (p = 0.018) in the endoscopic group. In this group there was also a lower incidence of CSF leaks and a shorter length of stay for secreting tumours (p = 0.005). 1 patient in the endoscopic group died at day 43 post-operatively, having initially presented in a poor clinical state with pituitary apoplexy. Microscopic trans-sphenoidal surgery remains the benchmark for future surgical techniques. Our early results suggest that endoscopic trans-sphenoidal surgery provides favourable results in both tumour resection and control of secreting tumours in comparison with microscopic surgery. Further longer-term evaluation is required to ensure the outcome of endoscopic surgery.
Ichikawa, Tsuyoshi; Suzuki, Kyouichi; Watanabe, Yoichi; Sato, Taku; Sakuma, Jun; Saito, Kiyoshi
2016-01-01
To perform intraoperative fluorescence angiography (FAG) under a microscope without an integrated FAG function with reasonable cost and sufficient quality for evaluation, we made a small and easy to use device for fluorescein FAG (FAG filter). We investigated the practical use of this FAG filter during aneurysm surgery, revascularization surgery, and brain tumor surgery. The FAG filter consists of two types of filters: an excitatory filter and a barrier filter. The excitatory filter excludes all wavelengths except for blue light and the barrier filter passes long waves except for blue light. By adding this FAG filter to a microscope without an integrated FAG function, light from the microscope illuminating the surgical field becomes blue, which is blocked by the barrier filter. We put the FAG filter on the objective lens of the operating microscope correctly and fluorescein sodium was injected intravenously or intra-arterially. Fluorescence (green light) from vessels in the surgical field and the dyed tumor were clearly observed through the microscope and recorded by a memory device. This method was easy and could be performed in a short time (about 10 seconds). Blood flow of small vessels deep in the surgical field could be observed. Blood flow stagnation could be evaluated. However, images from this method were inferior to those obtained by currently commercially available microscopes with an integrated FAG function. In brain tumor surgery, a stained tumor on the brain surface could be observed using this method. FAG could be performed with a microscope without an integrated FAG function easily with only this FAG filter.
ICHIKAWA, Tsuyoshi; SUZUKI, Kyouichi; WATANABE, Yoichi; SATO, Taku; SAKUMA, Jun; SAITO, Kiyoshi
2016-01-01
To perform intraoperative fluorescence angiography (FAG) under a microscope without an integrated FAG function with reasonable cost and sufficient quality for evaluation, we made a small and easy to use device for fluorescein FAG (FAG filter). We investigated the practical use of this FAG filter during aneurysm surgery, revascularization surgery, and brain tumor surgery. The FAG filter consists of two types of filters: an excitatory filter and a barrier filter. The excitatory filter excludes all wavelengths except for blue light and the barrier filter passes long waves except for blue light. By adding this FAG filter to a microscope without an integrated FAG function, light from the microscope illuminating the surgical field becomes blue, which is blocked by the barrier filter. We put the FAG filter on the objective lens of the operating microscope correctly and fluorescein sodium was injected intravenously or intra-arterially. Fluorescence (green light) from vessels in the surgical field and the dyed tumor were clearly observed through the microscope and recorded by a memory device. This method was easy and could be performed in a short time (about 10 seconds). Blood flow of small vessels deep in the surgical field could be observed. Blood flow stagnation could be evaluated. However, images from this method were inferior to those obtained by currently commercially available microscopes with an integrated FAG function. In brain tumor surgery, a stained tumor on the brain surface could be observed using this method. FAG could be performed with a microscope without an integrated FAG function easily with only this FAG filter. PMID:26597335
Scanning Electron Microscopic Evaluation of Several Resharpening Techniques.
1982-08-19
AD-AI20 320 ARMY INST OF DENTAL RESEARCH WASHINGTON OC F/6 6/5 SCANNING ELECTRON MICROSCOPIC EVALUATION OF SEVERAL RESHARPENIN-ETC(U) UNLASSIFIE D...NIT NUMBERS US Army Institute of Dental Research Walter Reed Army Medical Center N/A Washington, DC 20012 it. CONTROLLING OFFICE NAME AND ADORESS I...several resharpening techniques by Donald J. DeNucci, DDS, MS and Carson L. Mader, DMD, MSD United States Army Institute of Dental Research Walter Reed
NASA Astrophysics Data System (ADS)
Hong, S. Lee; Bodfish, James W.; Newell, Karl M.
2006-03-01
We investigated the relationship between macroscopic entropy and microscopic complexity of the dynamics of body rocking and sitting still across adults with stereotyped movement disorder and mental retardation (profound and severe) against controls matched for age, height, and weight. This analysis was performed through the examination of center of pressure (COP) motion on the mediolateral (side-to-side) and anteroposterior (fore-aft) dimensions and the entropy of the relative phase between the two dimensions of motion. Intentional body rocking and stereotypical body rocking possessed similar slopes for their respective frequency spectra, but differences were revealed during maintenance of sitting postures. The dynamics of sitting in the control group produced lower spectral slopes and higher complexity (approximate entropy). In the controls, the higher complexity found on each dimension of motion was related to a weaker coupling between dimensions. Information entropy of the relative phase between the two dimensions of COP motion and irregularity (complexity) of their respective motions fitted a power-law function, revealing a relationship between macroscopic entropy and microscopic complexity across both groups and behaviors. This power-law relation affords the postulation that the organization of movement and posture dynamics occurs as a fractal process.
Raman-atomic force microscopy of the ommatidial surfaces of Dipteran compound eyes.
Anderson, Mark S; Gaimari, Stephen D
2003-06-01
The ommatidial lens surfaces of the compound eyes in several species of files (Insecta: Diptera) and a related order (Mecoptera) were analyzed using a recently developed Raman-atomic force microscope. We demonstrate in this work that the atomic force microscope (AFM) is a potentially useful instrument for gathering phylogenetic data and that the newly developed Raman-AFM may extend this application by revealing nanometer-scale surface chemistry. This is the first demonstration of apertureless near-field Raman spectroscopy on an intact biological surface. For Chrysopilus testaceipes Bigot (Rhagionidae), this reveals unique cerebral cortex-like surface ridges with periodic variation in height and surface chemistry. Most other Brachyceran flies, and the "Nematoceran" Sylvicola fenestralis (Scopoli) (Anisopodidae), displayed the same morphology, while other taxa displayed various other characteristics, such as a nodule-like (Tipula (Triplicitipula) sp. (Tipulidae)) or coalescing nodule-like (Tabanus punctifer Osten Sacken (Tabanidae)) morphology, a smooth morphology with distinct pits and grooves (Dilophus orbatus (Say) (Bibionidae)), or an entirely smooth surface (Bittacus chlorostigma MacLachlan (Mecoptera: Bittacidae)). The variation in submicrometer structure and surface chemistry provides a new information source of potential phylogenetic importance, suggesting the Raman-atomic force microscope could provide a new tool useful to systematic and evolutionary inquiry.
Raman-atomic force microscopy of the ommatidial surfaces of Dipteran compound eyes
NASA Technical Reports Server (NTRS)
Anderson, Mark S.; Gaimari, Stephen D.
2003-01-01
The ommatidial lens surfaces of the compound eyes in several species of files (Insecta: Diptera) and a related order (Mecoptera) were analyzed using a recently developed Raman-atomic force microscope. We demonstrate in this work that the atomic force microscope (AFM) is a potentially useful instrument for gathering phylogenetic data and that the newly developed Raman-AFM may extend this application by revealing nanometer-scale surface chemistry. This is the first demonstration of apertureless near-field Raman spectroscopy on an intact biological surface. For Chrysopilus testaceipes Bigot (Rhagionidae), this reveals unique cerebral cortex-like surface ridges with periodic variation in height and surface chemistry. Most other Brachyceran flies, and the "Nematoceran" Sylvicola fenestralis (Scopoli) (Anisopodidae), displayed the same morphology, while other taxa displayed various other characteristics, such as a nodule-like (Tipula (Triplicitipula) sp. (Tipulidae)) or coalescing nodule-like (Tabanus punctifer Osten Sacken (Tabanidae)) morphology, a smooth morphology with distinct pits and grooves (Dilophus orbatus (Say) (Bibionidae)), or an entirely smooth surface (Bittacus chlorostigma MacLachlan (Mecoptera: Bittacidae)). The variation in submicrometer structure and surface chemistry provides a new information source of potential phylogenetic importance, suggesting the Raman-atomic force microscope could provide a new tool useful to systematic and evolutionary inquiry.
U.S. EPA Method 1623 is used to detect and quantify Cruptosporidum spp. oocysts in ater. The protocol consists of filtration, immunomagnetic separation (IMS), staining with a fluorescent antibody, and microscopic analysis. Microscopic analysis includes detection by fluorescent ...
Fathi, M M; El-Dlebshany, A E; El-Deen, M Bahie; Radwan, L M; Rayan, G N
2016-11-01
An experiment was conducted to evaluate egg quality and ultrastuctural measurements of eggshell using a Scanning Electron Microscope (SEM) in 2 lines (selected and control) of Japanese quail. A selection program was applied over 22 consecutive generations for higher egg production and lower broken egg percentage. The results revealed that the females of the selected line produced significantly (P < 0.01) higher egg mass compared to that of the control line. Also, the selection procedure significantly improved feed conversion ratio. The eggshells of the selected line had a higher breaking strength compared to those of the control line, although there was no difference between them in shell thickness. Significantly higher wet (P < 0.01) and dry (P < 0.05) eggshell percentages were found in the selected line. In general, the eggshells of the selected line had a lower total score (good) of ultrastructural evaluation compared to the control line. According to scanning electron microscope data, the incidence of certain structural variants was more common in eggshells of the control line suggesting poor shell strength. The incidence of alignment was more prevalent in control eggshells compared to selected ones, suggesting lower resistance to breakage. Late fusion and large interstitial spaces of the palisade layer indicating decreased resistance to fracture were observed in control eggshells. It could be concluded that the improvement eggshell quality may be caused by the long-term selection for lower cracked and broken egg rates from generation to generation. © 2016 Poultry Science Association Inc.
Akkad, Dina M. H. El; El-Gebaly, Naglaa Saad M.; Yousof, Hebat-Allah Salah A.; Ismail, Mousa A. M.
2016-01-01
Head lice, Pediculus humanus capitis, infestation is an important public health problem in Egypt. Inadequate application of topical pediculicides and the increasing resistance to the commonly used pediculicides made the urgent need for the development of new agents able to induce irreversible changes in the exposed lice leading to their mortality. The aim of the present work is to evaluate pediculicidal efficacy of some natural products such as olive oil, tea tree oil, lemon juice, and ivermectin separately in comparison with tetramethrin-piperonyl butoxide (licid), as a standard pediculicide commonly used in Egypt. The effects of these products were evaluated by direct observation using dissecting and scanning electron microscopes (SEM). Results showed that after 1 hr exposure time in vitro, absolute (100%) mortalities were recorded after exposure to 1% ivermectin and fresh concentrate lemon juice. The mortalities were decreased to 96.7% after exposure to tea tree oil. Very low percentage of mortality (23.3%) was recorded after 1 hr of exposure to extra virgin olive oil. On the other hand, the reference pediculicide (licid) revealed only mortality rate of 93.3%. On the contrary, no mortalities were recorded in the control group exposed to distilled water. By SEM examination, control lice preserved outer smooth architecture, eyes, antenna, respiratory spiracles, sensory hairs, and legs with hook-like claws. In contrast, dead lice which had been exposed to pediculicidal products showed damage of outer smooth architecture, sensory hairs, respiratory spiracles and/or clinching claws according to pediculicidal products used. PMID:27658606
Regenerating Heart Using a Novel Compound and Human Wharton Jelly Mesenchymal Stem Cells.
Rabbani, Shahram; Soleimani, Masoud; Imani, Mohammad; Sahebjam, Mohammad; Ghiaseddin, Ali; Nassiri, Seyed Mahdi; Majd Ardakani, Jalil; Tajik Rostami, Maryam; Jalali, Arash; Mousanassab, Bahmanshir; Kheradmandi, Mahsa; Ahmadi Tafti, Seyed Hossein
2017-04-01
Myocardial infarction is a major problem in health system and most conventional therapy is not led to restoration of the health. Stem cell therapy is a method to regenerate the heart but today appropriate cell source and scaffold selection as extracellular matrix to achieve the best effect is disputing. In this study a combination of human Wharton jelly mesenchymal stem cells (HWJMSCs) with a novel compound consisting polyethylene glycol (PEG), hyaluronic acid and chitosan is presented to heart regeneration. After proliferation and expansion of HWJMSCs, these cells were mixed with scaffold and injected into the infarcted rabbit myocardium. After two months cardiac function and infarcted area were evaluated. Immunohistochemistry performed for vessel count and demonstrating of differentiation ability into cardiomyocytes. To confirm this ability PCR was done. Scanning electron microscope was used to evaluate angiogenesis. Improving cardiac function was higher in cell/scaffold group than the others and it was confirmed by SPECT results which showed least defect size in the myocardium. There were a lot of neoangiogenesis in the target group and also cardiomyogenesis observed in cell/scaffold group. PCR results confirmed the presence of differentiated cardiomyocytes and SEM showed well developed vessel in this group. Comparing macroscopic and microscopic results between all groups revealed that HWJMSC in combination with this scaffold led to brilliant results regarding cardiac function, angiogenesis and cardiogenesis. It is recommended using these cells and materials for cardiac tissue engineering and regeneration therapy. Copyright © 2017 IMSS. Published by Elsevier Inc. All rights reserved.
Karvonen, Henna M; Lehtonen, Siri T; Sormunen, Raija T; Harju, Terttu H; Lappi-Blanco, Elisa; Bloigu, Risto S; Kaarteenaho, Riitta L
2012-09-01
The characteristic features of myofibroblasts in various lung disorders are poorly understood. We have evaluated the ultrastructure and invasive capacities of myofibroblasts cultured from small volumes of diagnostic bronchoalveolar lavage (BAL) fluid samples from patients with different types of lung diseases. Cells were cultured from samples of BAL fluid collected from 51 patients that had undergone bronchoscopy and BAL for diagnostic purposes. The cells were visualized by transmission electron microscopy and immunoelectron microscopy to achieve ultrastructural localization of alpha-smooth muscle actin (α-SMA) and fibronectin. The levels of α-SMA protein and mRNA and fibronectin mRNA were measured by western blot and quantitative real-time reverse transcriptase polymerase chain reaction. The invasive capacities of the cells were evaluated. The cultured cells were either fibroblasts or myofibroblasts. The structure of the fibronexus, and the amounts of intracellular actin, extracellular fibronectin and cell junctions of myofibroblasts varied in different diseases. In electron and immunoelectron microscopy, cells cultured from interstitial lung diseases (ILDs) expressed more actin filaments and α-SMA than normal lung. The invasive capacity of the cells obtained from patients with idiopathic pulmonary fibrosis was higher than that from patients with other type of ILDs. Cells expressing more actin filaments had a higher invasion capacity. It is concluded that electron and immunoelectron microscopic studies of myofibroblasts can reveal differential features in various diseases. An analysis of myofibroblasts cultured from diagnostic BAL fluid samples may represent a new kind of tool for diagnostics and research into lung diseases.
Shafiu Kamba, Abdullahi; Ismail, Maznah; Tengku Ibrahim, Tengku Azmi; Zakaria, Zuki Abu Bakar; Hassan Gusau, Lawal
2014-01-01
Bones are the most frequent site for breast cancer cells to settle and spread (metastasise); bone metastasis is considered to have a substantial impact on the quality of patients with common cancers. However, majority of breast cancers develop insensitivity to conventional chemotherapy which provides only palliation and can induce systemic side effects. In this study we evaluated the effect of free Dox and CaCO3/Dox nanocrystal on MCF-7 breast cancer using MTT (3-[4, 5-dimethylthiazol-2-yl]-2, 5-diphenyl tetrazolium bromide), neural red, and lactate dehydrogenase colorimetric assays while DNA fragmentation and BrdU genotoxicity were also examined. Apoptogenic protein Bax, cytochrome C, and caspase-3 protein were analysed. Morphological changes of MCF-7 were determined using contrast light microscope and scanning and transmission electron microscope (SEM and TEM). The findings of the analysis revealed higher toxicity of CaCO3/Dox nanocrystal and effective cells killing compared to free Dox, morphological changes such as formation of apoptotic bodies, membrane blebbing, and absent of microvilli as indicated by the SEM analysis while TEM revealed the presence of chromatin condensation, chromosomal DNA fragmentation, cell shrinkage, and nuclear fragmentation. Results of TUNEL assay verified that most of the cells undergoes apoptosis by internucleosomal fragmentation of genomic DNA whereas the extent of apoptotic cells was calculated using the apoptotic index (AI). Therefore, the biobased calcium carbonate nanocrystals such as Dox carriers may serve as an alternative to conventional delivery system. PMID:25028650
Wu, Yong-Xiang; Zhu, Guo-Xia; Liu, Xin-Qin; Sun, Fei; Zhou, Ke; Wang, Shuang; Wang, Chun-Mei; Jia, Jin-Wen; Song, Jian-Tao; Lu, Lian-Jun
2014-12-24
Noise exposure (NE) is a severe modern health hazard that induces hearing impairment. However, the noise-induced ultrastructural changes of blood-labyrinth barrier (BLB) and the potential involvements of tight junction proteins (TJP) remain inconclusive. We investigated the effects of NE on not only the ultrastructure of cochlea and permeability of BLB but also the expression of TJP within the guinea pig cochlea. Male albino guinea pigs were exposed to white noise for 4 h or 2 consecutive days (115 dB sound pressure level, 6 hours per day) and the hearing impairments and light microscopic change of BLB were evaluated with auditory brainstem responses (ABR) and the cochlear sensory epithelia surface preparation, respectively. The cochlear ultrastructure and BLB permeability after NE 2d were revealed with transmission electron microscope (TEM) and lanthanum nitrate-tracing techniques, respectively. The potential alterations of TJPs Claudin-5 and Occludin were quantified with immunohistochemistry and western blot. NE induced significant hearing impairment and NE 2d contributed to significant outer hair cell (OHC) loss that is most severe in the first row of outer hair cells. Furthermore, the loosen TJ and an obvious leakage of lanthanum nitrate particles beneath the basal lamina were revealed with TEM. Moreover, a dose-dependent decrease of Claudin-5 and Occludin was observed in the cochlea after NE. All these findings suggest that both decrease of Claudin-5 and Occludin and increased BLB permeability are involved in the pathologic process of noise-induced hearing impairment; however, the causal relationship and underlying mechanisms should be further investigated.
Clinical Evaluation of Tylosin as a Treatment of Vibrionic Dysentery in Swine
Doornenbal, H.
1965-01-01
A 5 year history of swine dysentery and treatment has been described. In 1964, a severe outbreak diagnosed as Vibrionic dysentery in 166 litters farrowed from January — March caused a death loss of 30.3 per cent of the total number weaned. This outbreak was not checked with an organic arsenic, sodium arsanilate, which had previously been relatively effective. A subsequent farrow of 133 litters (June — August, 1964) was infected and again sodium arsanilate was ineffective. Microscopic examination of smears of representative fecal samples revealed the presence of a heavy concentration of vibrio-like organisms. Two test-barns, housing 140 and 172 pigs respectively, were treated with tylosin-tartrate, using one side of each barn as a control, while the other side was being treated. Subsequently, the control sides were treated. Both levels of tylosin used, 1 gm and 2 gm per U.S. gallon of water, resulted in the disappearance of fluid feces within 48 hours of treatment. Soft, granular feces were still present 6-9 days after the start of treatment at the 1 gm level, while in case of the 2 gm level of tylosin, all feces were normal on the third day after medication started. Microscopic examination of feces collected on the third day of treatment still revealed the presence of some vibrio-like organisms. However, these organisms could not be detected in examination of feces collected between 10 to 25 days after treatment. In this test there was no recurrence of dysentery. ImagesFIG. 1FIG. 2 PMID:14300858
NASA Astrophysics Data System (ADS)
Sharifi Golru, S.; Attar, M. M.; Ramezanzadeh, B.
2015-08-01
The objective of this work is to investigate the effects of zirconium-based (Zr) conversion coating on the adhesion properties and corrosion resistance of an epoxy/polyamide coating applied on the aluminium alloy 1050 (AA1050). Field emission scanning electron microscope (FE-SEM), energy dispersive X-ray spectrum (EDS), atomic force microscope (AFM) and contact angle measuring device were employed in order to characterize the surface characteristics of the Zr treated AA1050 samples. The epoxy/polyamide coating was applied on the untreated and Zr treated samples. The epoxy coating adhesion to the aluminium substrate was evaluated by pull-off test before and after 30 days immersion in 3.5% w/w NaCl solution. In addition, the electrochemical impedance spectroscopy (EIS) and salt spray tests were employed to characterize the corrosion protection properties of the epoxy coating applied on the AA1050 samples. Results revealed that the surface treatment of AA1050 by zirconium conversion coating resulted in the increase of surface free energy and surface roughness. The dry and recovery (adhesion strength after 30 days immersion in the 3.5 wt% NaCl solution) adhesion strengths of the coatings applied on the Zr treated aluminium samples were greater than untreated sample. In addition, the adhesion loss of the coating applied on the Zr treated aluminium substrate was lower than other samples. Also, the results obtained from EIS and salt spray test clearly revealed that the Zr conversion coating could enhance the corrosion protective performance of the epoxy coating significantly.
Santer, Melvin
2009-01-01
During the years 1714 to 1721, Richard Bradley, who was later to become the first Professor of Botany at Cambridge University, proposed a unified, unique, living agent theory of the cause of infectious diseases of plants and animals and the plague of humans. Bradley's agents included microscopic organisms, revealed by the studies of Robert Hooke and Antony van Leeuwenhoek. His theory derived from his experimental studies of plants and their diseases and from microscopic observation of animalcules in different naturally occurring and artificial environments. He concluded that there was a microscopic world of "insects" that lived and reproduced under the appropriate conditions, and that infectious diseases of plants were caused by such "insects." Since there are structural and functional similarities between plants and animals, Bradley concluded that microscopic organisms caused human and animal infectious diseases as well. However, his living agent cause of infectious diseases was not accepted by the contemporary scientific society.
Acoustical nanometre-scale vibrations of live cells detected by a near-field optical setup
NASA Astrophysics Data System (ADS)
Piga, Rosaria; Micheletto, Ruggero; Kawakami, Yoichi
2007-04-01
The Scanning Near-field Optical Microscope (SNOM) is able to detect tiny vertical movement on the cell membrane in the range of only 1 nanometer or less, about 3 orders of magnitude better than conventional optical microscopes. Here we show intriguing data of cell membrane nanometer-scale dynamics associated to different phenomena of the cell’s The Scanning Near-field Optical Microscope (SNOM) is able to detect tiny vertical movement on the cell membrane in the range of only 1 nanometer or less, about 3 orders of magnitude better than conventional optical microscopes. Here we show intriguing data of cell membrane nanometer-scale dynamics associated to different phenomena of the cell’s life, such as cell cycle and cell death, on rat pheochromocytoma line PC12. Working in culture medium with alive and unperturbed samples, we could detect nanometer-sized movements; Fourier components revealed a clear distinct behavior associated to regulation of neurite outgrowth and changes on morphology after necrotic stimulus.
Multiresolution multiscale active mask segmentation of fluorescence microscope images
NASA Astrophysics Data System (ADS)
Srinivasa, Gowri; Fickus, Matthew; Kovačević, Jelena
2009-08-01
We propose an active mask segmentation framework that combines the advantages of statistical modeling, smoothing, speed and flexibility offered by the traditional methods of region-growing, multiscale, multiresolution and active contours respectively. At the crux of this framework is a paradigm shift from evolving contours in the continuous domain to evolving multiple masks in the discrete domain. Thus, the active mask framework is particularly suited to segment digital images. We demonstrate the use of the framework in practice through the segmentation of punctate patterns in fluorescence microscope images. Experiments reveal that statistical modeling helps the multiple masks converge from a random initial configuration to a meaningful one. This obviates the need for an involved initialization procedure germane to most of the traditional methods used to segment fluorescence microscope images. While we provide the mathematical details of the functions used to segment fluorescence microscope images, this is only an instantiation of the active mask framework. We suggest some other instantiations of the framework to segment different types of images.
[Evaluation of the surface of the new intraocular lenses in the scanning electron microscope].
Kałuzny, B J; Szatkowski, J; Kałuzny, J J
2001-01-01
To evaluate the surface of the new PC IOLs commercially available in Poland in 2000. Representative samples of new posterior chamber IOLs produced by 6 different companies (Alcon, Lensita, Medicontur, Opsia, Rayner, Storz), 5 of each, underwent surface examination with Novoscan 30 scanning electron microscope. Although, in general, smooth surface of optic and haptic parts were observed, three samples with irregularities were found. Comparing to previous evaluation performed in 1994, significant improvement in quality of IOLs surface was noted. No considerable differences in this field between above mentioned producers were observed.
Masuda, Yoshiko Murakami; Hossain, Mozammal; Wang, Xiaogu; Matsuoka, Emi; Okano, Tomohiro; Matsumoto, Koukichi
2006-09-01
To investigate the efficacy of Er,Cr:YSGG (erbium,chromium:yttrium scandium gallium garnet) laser irradiation in root canal preparation and to evaluate its effect on eruption of rat incisors after disturbance of the enamel organ in the pulp, 20 canals of lower left incisor teeth were prepared by K-files followed by Er,Cr:YSGG laser irradiation, and 20 canals of right incisors were subjected to K-files only (control). At 1 week after irradiation, both sides of incisors erupted at the same level from the gingival margin. Histological findings showed that laser irradiation produced a slightly larger damage in the pulp than that of control. Scanning electron microscope observation revealed that laser-treated surface revealed a rough, irregular, and very clean surface; there was almost no evidence of debris or smear layer, and dentinal tubules were opened. Adequate power of Er,Cr:YSGG laser irradiation is effective in root canal preparation without disturbance of the eruption.
Sangappa, M.; Thiagarajan, Padma
2015-01-01
The antibiogram study of methicillin resistant Staphylococcus aureus isolates revealed 100% resistance to vancomycin, bacitracin, erythromycin, ciprofloxacin and nalidixic acid. Eight isolates (53.3%) showed resistance to co-trimoxazole and one isolate to rifampicin, which was the drug of choice. An effort was made to evaluate the antimethicillin resistant Staphylococcus aureus activity of silver oxide (Ag2O) nanoparticles synthesized from Aspergillus terreus VIT 2013. Production of Ag2O nanoparticles was confirmed by color change of fungal filtrate and UV light absorption at 450 nm. X-ray diffraction pattern showed 2θ values at 27, 32, 38 and 57°, which corresponded to the cubic structure of Ag2O nanocrystals. Fourier transform infrared spectroscopy indicated the presence of primary amine, carbonyl group, NO2 and silver, revealing protein mediated nanoparticle production. The scanning electron microscope image showed freely dispersed Ag2O nanoparticles. The nanoparticles were active against all methicillin resistant isolates and hence can be used as antibacterial agents against drug resistant bacteria. PMID:26009646
Sass, H J; Büldt, G; Beckmann, E; Zemlin, F; van Heel, M; Zeitler, E; Rosenbusch, J P; Dorset, D L; Massalski, A
1989-09-05
Porin is an integral membrane protein that forms channels across the outer membrane of Escherichia coli. Electron microscopic studies of negatively stained two-dimensional porin crystals have shown three stain accumulations per porin trimer, revealing the locations of pores spanning the membrane. In this study, reconstituted porin lattices embedded in glucose were investigated using the low-dose technique on a cryo-electron microscope equipped with a helium-cooled superconducting objective lens. The specimen temperature was maintained at 5 K to yield an improved microscopic and specimen stability. Under these conditions, we obtained for the first time electron diffraction patterns from porin lattices to a resolution of 3.2 A and images showing optical diffraction up to a resolution of 4.9 A. Applying correlation averaging techniques to the digitized micrographs, we were able to reconstruct projected images of the porin trimer to a resolution of up to 3.5 A. In the final projection maps, amplitudes from electron diffraction and phases from these images were combined. The predominant feature is a high-density narrow band (about 6 A in thickness) that delineates the outer perimeter of the trimer. Since the molecule consists of almost exclusively beta-sheet structure, as revealed by spectroscopic data, we conclude that this band is a cylindrical beta-pleated sheet crossing the membrane nearly perpendicularly to its plane. Another intriguing finding is a low-density area (about 70 A2) situated in the centre of the trimer.
Microscopic studies of polycrystalline nanoparticle growth in free space
NASA Astrophysics Data System (ADS)
Mohan, A.; Kaiser, M.; Verheijen, M. A.; Schropp, R. E. I.; Rath, J. K.
2017-06-01
We have extensively studied by multiple microscopic techniques the growth and crystallization of silicon nanoparticles in pulsed SiH4/Ar plasmas. We observe that the crystallinity of the particles can be tuned from amorphous to crystalline by altering the plasma ON time, tON. Three phases can be identified as a function of tON. Microscopic studies reveal that, in the initial gas phase (phase I) single particles of polycrystalline nature are formed which according to our hypothesis grow out of a single nucleus. The individual crystallites of the polycrystalline particles become bigger crystalline regions which marks the onset of cauliflower shaped particles (phase II). At longer tON (phase III) distinct cauliflower particles are formed by the growth of these crystalline regions by local epitaxy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Shuai, E-mail: zhangshuai94@gmail.com; Zhang, Bo, E-mail: shizbcn@mail.tsinghua.edu.cn; He, Jinliang, E-mail: hejl@tsinghua.edu.cn
Corona discharge is one of the major design factors for extra-high voltage and ultra-high voltage DC/AC transmission lines. Under different voltages, corona discharge reveals different characteristics. This paper aims at investigating DC and AC coronas on the microscopic scale. To obtain the specific characteristics of DC and AC coronas, a new measurement approach that utilizes a coaxial wire-cylinder corona cage is designed in this paper, and wires of different diameters are used in the experiment. Based on the measurements, the respective microscopic characteristics of DC and AC coronas are analyzed and compared. With differences in characteristics between DC and ACmore » coronas proposed, this study provides useful insights into DC/AC corona discharges on transmission line applications.« less
Iancu, Violeta; Hla, Saw-Wai
2006-01-01
Single chlorophyll-a molecules, a vital resource for the sustenance of life on Earth, have been investigated by using scanning tunneling microscope manipulation and spectroscopy on a gold substrate at 4.6 K. Chlorophyll-a binds on Au(111) via its porphyrin unit while the phytyl-chain is elevated from the surface by the support of four CH3 groups. By injecting tunneling electrons from the scanning tunneling microscope tip, we are able to bend the phytyl-chain, which enables the switching of four molecular conformations in a controlled manner. Statistical analyses and structural calculations reveal that all reversible switching mechanisms are initiated by a single tunneling-electron energy-transfer process, which induces bond rotation within the phytyl-chain. PMID:16954201
Ehlers, Justis P.; Tao, Yuankai K.; Farsiu, Sina; Maldonado, Ramiro; Izatt, Joseph A.
2011-01-01
Purpose. To demonstrate an operating microscope-mounted spectral domain optical coherence tomography (MMOCT) system for human retinal and model surgery imaging. Methods. A prototype MMOCT system was developed to interface directly with an ophthalmic surgical microscope, to allow SDOCT imaging during surgical viewing. Nonoperative MMOCT imaging was performed in an Institutional Review Board–approved protocol in four healthy volunteers. The effect of surgical instrument materials on MMOCT imaging was evaluated while performing retinal surface, intraretinal, and subretinal maneuvers in cadaveric porcine eyes. The instruments included forceps, metallic and polyamide subretinal needles, and soft silicone-tipped instruments, with and without diamond dusting. Results. High-resolution images of the human retina were successfully obtained with the MMOCT system. The optical properties of surgical instruments affected the visualization of the instrument and the underlying retina. Metallic instruments (e.g., forceps and needles) showed high reflectivity with total shadowing below the instrument. Polyamide material had a moderate reflectivity with subtotal shadowing. Silicone instrumentation showed moderate reflectivity with minimal shadowing. Summed voxel projection MMOCT images provided clear visualization of the instruments, whereas the B-scans from the volume revealed details of the interactions between the tissues and the instrumentation (e.g., subretinal space cannulation, retinal elevation, or retinal holes). Conclusions. High-quality retinal imaging is feasible with an MMOCT system. Intraoperative imaging with model eyes provides high-resolution depth information including visualization of the instrument and intraoperative tissue manipulation. This study demonstrates a key component of an interactive platform that could provide enhanced information for the vitreoretinal surgeon. PMID:21282565
Ehlers, Justis P; Tao, Yuankai K; Farsiu, Sina; Maldonado, Ramiro; Izatt, Joseph A; Toth, Cynthia A
2011-05-16
To demonstrate an operating microscope-mounted spectral domain optical coherence tomography (MMOCT) system for human retinal and model surgery imaging. A prototype MMOCT system was developed to interface directly with an ophthalmic surgical microscope, to allow SDOCT imaging during surgical viewing. Nonoperative MMOCT imaging was performed in an Institutional Review Board-approved protocol in four healthy volunteers. The effect of surgical instrument materials on MMOCT imaging was evaluated while performing retinal surface, intraretinal, and subretinal maneuvers in cadaveric porcine eyes. The instruments included forceps, metallic and polyamide subretinal needles, and soft silicone-tipped instruments, with and without diamond dusting. High-resolution images of the human retina were successfully obtained with the MMOCT system. The optical properties of surgical instruments affected the visualization of the instrument and the underlying retina. Metallic instruments (e.g., forceps and needles) showed high reflectivity with total shadowing below the instrument. Polyamide material had a moderate reflectivity with subtotal shadowing. Silicone instrumentation showed moderate reflectivity with minimal shadowing. Summed voxel projection MMOCT images provided clear visualization of the instruments, whereas the B-scans from the volume revealed details of the interactions between the tissues and the instrumentation (e.g., subretinal space cannulation, retinal elevation, or retinal holes). High-quality retinal imaging is feasible with an MMOCT system. Intraoperative imaging with model eyes provides high-resolution depth information including visualization of the instrument and intraoperative tissue manipulation. This study demonstrates a key component of an interactive platform that could provide enhanced information for the vitreoretinal surgeon.
Só, Marcus Vinícius Reis; De Figueiredo, Jose Antônio Poli; Freitas Fachin, Elaine Vianna; Húngaro Duarte, Marco Antônio; Pereira, Jefferson Ricardo; Kuga, Milton Carlos; Da Rosa, Ricardo Abreu
2012-09-01
To evaluate the efficacy of ProTaper Universal rotary retreatment system and the influence of sealer type on the presence of filling debris in the reinstrumented canals viewed in an operative clinical microscope. Forty-five palatal root canals of first molars were filled with gutta-percha and one of the following sealers: G1, EndoFill; G2, AH Plus; G3, Sealapex. The canals were then reinstrumented with ProTaper Universal rotary system. Roots were longitudinally sectioned and examined under an operative clinical microscope (10×), and the amount of filling debris on canal walls was analyzed using the AutoCAD 2004 software. A single operator used a specific software tool to outline the canal area and the filling debris area in each third (cervical, middle, and apical), as well as the total canal area. Data were analyzed by Kruskal-Wallis test and Tukey test at P < 0.05. Sealapex demonstrated significant differences in the average of filling debris area/canal among the 3 thirds. This group revealed that apical third showed more debris than the both cervical and middle third (P < 0.0001). Endofill presented significantly more filling debris than Sealapex in the cervical third (P < 0.05). In the middle (P = 0.12) and apical third (P = 0.10), there were no differences amongst groups. Debris was left in all canal thirds, regardless of the retreatment technique. The greatest differences between techniques and sealers were found in the cervical third. Copyright © 2012 Wiley Periodicals, Inc.
Zhang, Yushu; Zhang, Chuanlian; Liu, Kemiao; Zhu, Xia; Liu, Fang; Ge, Xiaofen
2018-05-01
The aim of the present study is to develop novel approach for the green synthesis of titanium oxide nanoparticles (TiO 2 NPs) using Eichhornia crassipes extract and calcined at different temperatures for evaluate the wound healing activity in the femoral fracture. The synthesized TiO 2 are formed different (plate and rod-like) nanostructures at various calcination temperatures. These samples were characterized by X-ray diffraction (XRD), Fourier transform-infrared spectroscopy (FTIR), Field emission scanning electron microscope (FE-SEM) and transmission electron microscope (TEM). Microscopic studies of TiO 2 NPs revealed that the synthesized TiO 2 NPs are formed well-defined rod-like structures at 400 °C with size ranged from 200 nm to 500 nm. The characterized plate and rod-like TiO 2 NPs are combined with human morphogenetic protein (HbMP) to improving its wound healing activity and osteoblast properties on femoral fractures. The biocompatibility was tested by using human bone marrow mesenchymal stem cells (BMSC) cells and antibacterial efficacy analyzed using human pathogenica bacteria Staphylococcus aureus and Escherichia coli through agar well diffusion assay. The green synthesized rod-like TiO 2 NPs combined with HbMP has been exhibited effective bone fusion behaviors with biomechanical properties and also improved antibacterial activity against pathogenic bacteria. From this study results, it is suggested that green synthesized TiO 2 NPs could be used effectively in biomedical application. Copyright © 2018. Published by Elsevier B.V.
NASA Technical Reports Server (NTRS)
2004-01-01
This image, taken by an instrument called the microscopic imager on the Mars Exploration Rover Spirit, reveals an imprint left by another instrument, the Moessbauer spectrometer. The imprint is at a location within the rover wheel track named 'Middle of Road.' Both instruments are located on the rover's instrument deployment device, or 'arm.'
Not only was the Moessbauer spectrometer able to gain important mineralogical information about this site, it also aided in the placement of the microscopic imager. On hard rocks, the microscopic imager uses its tiny metal sensor to determine proper placement for best possible focus. However, on the soft martian soil this guide would sink, prohibiting proper placement of the microscopic imager. After the Moessbauer spectrometer's much larger, donut-shaped plate touches the surface, Spirit can correctly calculate where to position the microscopic imager.Scientists find this image particularly interesting because of the compacted nature of the soil that was underneath the Moessbauer spectrometer plate. Also of interest are the embedded, round grains and the fractured appearance of the material disturbed within the hole. The material appears to be slightly cohesive. The field of view in this image, taken on Sol 43 (February 16, 2004), measures approximately 3 centimeters (1.2 inches) across.Cell adhesion monitoring of human induced pluripotent stem cell based on intrinsic molecular charges
NASA Astrophysics Data System (ADS)
Sugimoto, Haruyo; Sakata, Toshiya
2014-01-01
We have shown a simple way for real-time, quantitative, non-invasive, and non-label monitoring of human induced pluripotent stem (iPS) cell adhesion by use of a biologically coupled-gate field effect transistor (bio-FET), which is based on detection of molecular charges at cell membrane. The electrical behavior revealed quantitatively the electrical contacts of integrin-receptor at the cell membrane with RGDS peptide immobilized at the gate sensing surface, because that binding site was based on cationic α chain of integrin. The platform based on the bio-FET would provide substantial information to evaluate cell/material bio-interface and elucidate biding mechanism of adhesion molecules, which could not be interpreted by microscopic observation.
A case of bifocal endometriosis involving a pfannenstiel incision.
Evsen, Mehmet Sidik; Sak, Muhammet Erdal; Yalinkaya, Ahmet; Firat, Ugur; Caca, Fatma Nur
2011-01-01
A 25-year-old woman was referred to our clinic for atypical cyclic pain and masses at both ends of a Pfannenstiel incision scar. Ultrasound of the anterior abdominal wall showed two masses. Both masses were hypoechoic, heterogeneous lesions located at opposite ends of the scar. The lesions were surgically excised with. Microscopic examination revealed endometrial gland structures with endometrial stroma in fibroadipose tissue in sections of both specimens indicative of endometriosis. Incisional endometriosis (IE) is a form of extrapelvic endometriosis especially in scars of obstetric or gynecologic surgery IE may be multifocal at surgical scars. We report the a case of bifocal incisional endometriosis in Pfannesteil scar. Whole scar evaluation should be done for incisional endometriosis and surgical excision should be performed for treatment.
Structural and optical properties of ZnO nanorods synthesized via template free approach
NASA Astrophysics Data System (ADS)
Kajal, Priyanka; D, Pooja; Jaggi, Neena
2016-06-01
In this paper, we report a novel method for synthesis of semiconducting ZnO nanorods using Zinc acetate dehydrate precursor in a methanol—de-ionized (1:5) mixture via template free approach. Scanning electron microscope (SEM) and transmission electron microscope (TEM) images of as synthesized nanorods revealed hexagonal symmetry of rods, whereas x-ray diffraction (XRD) analysis for structure and phase has shown high crystallinity with wurtzite crystal structure. The structural characterization by FT-IR analysis revealed presence of various groups on as synthesized ZnO nanorods, whereas the UV-Vis analysis has shown a blue shift in the absorption spectra as compared to bulk ZnO due to quantum confinement of charge carriers. Photoluminescence (PL) spectroscopy study has also been performed revealing a good degree of phosphorescence in the ZnO nanorods. Further, thermo gravimetric analysis (TGA) revealed that as synthesized nanorods by present method are highly stable at high temperature (1000 °C). This study provides an alternative, less expensive and a very simple method for the fabrication of ZnO nanorods in abundance, which can be further used for various sensing applications, in particular, gas sensing.
NASA Astrophysics Data System (ADS)
Nebogatikov, V.; Nikitiuk, A.; Konysheva, A.; Ignatyev, P.; Grishko, V.; Naimark, O.
2017-09-01
Quantitative phase microscopy is a new method to measure and evaluate the microlevel processes characterized by the high resolution and providing ample opportunities to quantitatively analyze various parameters, including specimens from biological matter. In this study, a laser interference microscope was used to evaluate the state of cancer cells (living and apoptotic). Apoptotic cancer cells were obtained by treatment of MCF-7 cells with the use of betulin-based α-bromomethyl ketone (BMK) derivative. When using the microscope, the main differences in the morphometric parameters of living and apoptotic cells such as height, diameter, perimeter, area and volume were appraised. The criteria that can be used as markers of apoptosis activation were identified.
Khalaf, Salah; Ariffin, Zaihan; Husein, Adam; Reza, Fazal
2015-07-01
This study aimed to compare the surface roughness of maxillofacial silicone elastomers fabricated in noncoated and coated gypsum materials. This study was also conducted to characterize the silicone elastomer specimens after surfaces were modified. A gypsum mold was coated with clear acrylic spray. The coated mold was then used to produce modified silicone experimental specimens (n = 35). The surface roughness of the modified silicone elastomers was compared with that of the control specimens, which were prepared by conventional flasking methods (n = 35). An atomic force microscope (AFM) was used for surface roughness measurement of silicone elastomer (unmodified and modified), and a scanning electron microscope (SEM) was used to evaluate the topographic conditions of coated and noncoated gypsum and silicone elastomer specimens (unmodified and modified) groups. After the gypsum molds were characterized, the fabricated silicone elastomers molded on noncoated and coated gypsum materials were evaluated further. Energy-dispersive X-ray spectroscopy (EDX) analysis of gypsum materials (noncoated and coated) and silicone elastomer specimens (unmodified and modified) was performed to evaluate the elemental changes after coating was conducted. Independent t test was used to analyze the differences in the surface roughness of unmodified and modified silicone at a significance level of p < 0.05. Roughness was significantly reduced in the silicone elastomers processed against coated gypsum materials (p < 0.001). The AFM and SEM analysis results showed evident differences in surface smoothness. EDX data further revealed the presence of the desired chemical components on the surface layer of unmodified and modified silicone elastomers. Silicone elastomers with lower surface roughness of maxillofacial prostheses can be obtained simply by coating a gypsum mold. © 2014 by the American College of Prosthodontists.
Factors Essential for Prostate Cancer Metastasis Revealed Through a Novel 3D Microtissue Assay
2016-06-01
with Ob-niche spheroid and then conducted confocal microscopic analysis with frozen sections for HRE -mediated GFP expression. The results...activity in response to CoCl2. (B) The microscopic images demonstrate the HRE -dependent expression of GFP in a spheroid-specific manner. (C) The...io n C om bi ne d A375 MB231 Fr oz en s ec . 582 µm B C D SecNLuc Puro 4x HRE 0 5 10 15 None 100 A375 0 1 2 3 4 5 6 None 100
Electron microscopic and optical studies of prism faces of synthetic quartz
NASA Technical Reports Server (NTRS)
Buzek, B. C.; Vagh, A. S.
1977-01-01
Application of electron and optical microscopic techniques to the study of growth spirals on quartz crystal faces is described. Attention is centered on the centers of the spirals and on screw ledges; overhanging kinks are revealed on one side of the spiral centers. The possibility that these special features may have developed after growth of the crystals went to completion is explored. The conjecture is raised that such structures might result from adsorption of growth-inhibiting impurities at the center of the growth spiral on the quartz habit faces.
An ocular cysticercosis case: Caused by Asian genotype of Taenia solium.
Sharma, M; Beke, N; Khurana, S; Bhatti, H S; Sehgal, R; Malla, N
2015-01-01
An ocular cysticercosis case of a 42-year-old male, who presented with anterior uveitis is being reported. Microscopical examination of the cyst revealed presence of only one hooklet suggestive of T. solium cysticercus. Mitochondrial DNA analysis confirmed it to be T. solium cysticercus of Asian genotype. This is the first report on molecular typing of cysticercus isolate from ocular cysticercosis patient in India. The study suggests that the molecular analysis of cox1 gene may be a useful diagnostic tool in cases where microscopic examination is not confirmatory.
Clinical experience of external -route retinal detachment surgery under a surgical microscope.
Xu, Hui
2014-03-01
To evaluate the efficacy of external-route retinal reattachment surgery under a surgical microscope. A total of 86 patients (86 eyes) with rhegmatogenous retinal detachment underwent external-route retinal detachment surgery under a surgical microscope. Drainage of subretinal fluid, transscleral cryotherapy, scleral buckling, and intravitreal injection of gas were performed intraoperatively. Among 85 patients, 81 achieved postoperative retinal re-attachment after the first surgery and 5 after two surgeries. The visual acuity was elevated in 67 patients, unchanged in 15, and decreased in 4. External-route retinal reattachment surgery under a surgical microscope is a convenient procedure for physicians to master and worthy of widespread application in clinical settings.
Handy Microscopic Close-Range Videogrammetry
NASA Astrophysics Data System (ADS)
Esmaeili, F.; Ebadi, H.
2017-09-01
The modeling of small-scale objects is used in different applications such as medicine, industry, and cultural heritage. The capability of modeling small-scale objects using imaging with the help of hand USB digital microscopes and use of videogrammetry techniques has been implemented and evaluated in this paper. Use of this equipment and convergent imaging of the environment for modeling, provides an appropriate set of images for generation of three-dimensional models. The results of the measurements made with the help of a microscope micrometer calibration ruler have demonstrated that self-calibration of a hand camera-microscope set can help obtain a three-dimensional detail extraction precision of about 0.1 millimeters on small-scale environments.
Stothard, J Russell; Kabatereine, Narcis B; Tukahebwa, Edridah M; Kazibwe, Francis; Mathieson, William; Webster, Joanne P; Fenwick, Alan
2005-11-01
A novel, inexpensive handheld microscope, the Meade Readiview, was evaluated for field diagnosis of intestinal schistosomiasis by comparison of sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) against conventional compound microscopy as part of a parasitologic survey in nine sentinel schools and a rapid mapping survey across 22 schools in Uganda. Fecal smears from 685 primary school children were examined and the overall prevalence of Schistosoma mansoni was 45%. However, prevalence by school ranged widely from 0% to 100%. For individual diagnosis the Readiview had a sensitivity of 85%, a specificity of 96%, a PPV of 95%, and an NPV of 88%. Due to the poorer movement control of the glass slide on the Readiview stage, fecal smears with less than four eggs could be overlooked. At the highest magnification (160x), egg-like objects could be confounding. Estimating prevalence by school was usually within +/- 7% of that of conventional microscopy. Since the Readiview is more robust and portable, both in size and weight, and one-tenth as expensive as the traditional compound microscope, a change in the logistics and costs associated with field infection surveillance is possible. This inexpensive microscope is a pragmatic alternative to the compound microscope. It could play an important role in the collection of prevalence data to better guide anthelmintic drug delivery and also empower the diagnostic capacity of peripheral health centers where compound microscopes are few or absent.
Experimental evaluation of environmental scanning electron microscopes at high chamber pressure.
Fitzek, H; Schroettner, H; Wagner, J; Hofer, F; Rattenberger, J
2015-11-01
In environmental scanning electron microscopy (ESEM) high pressure applications have become increasingly important. Wet or biological samples can be investigated without time-consuming sample preparation and potential artefacts from this preparation can be neglected. Unfortunately, the signal-to-noise ratio strongly decreases with increasing chamber pressure. To evaluate the high pressure performance of ESEM and to compare different electron microscopes, information about spatial resolution and detector type is not enough. On the one hand, the scattering of the primary electron beam increases, which vanishes the contrast in images; and on the other hand, the secondary electrons (SE) signal amplification decreases. The stagnation gas thickness (effective distance the beam has to travel through the imaging gas) as well as the SE detection system depend on the microscope and for a complete and serious evaluation of an ESEM or low vacuum SEM it is necessary to specify these two parameters. A method is presented to determine the fraction of scattered and unscattered electrons and to calculate the stagnation gas thickness (θ). To evaluate the high pressure performance of the SE detection system, a method is presented that allows for an analysis of a single image and the calculation of the signal-to-noise ratio of this image. All investigations are performed on an FEI ESEM Quanta 600 (field emission gun) and an FEI ESEM Quanta 200 (thermionic gun). These methods and measurements should represent opportunities for evaluating the high pressure performance of an ESEM. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.
Bogoch, Isaac I; Koydemir, Hatice C; Tseng, Derek; Ephraim, Richard K D; Duah, Evans; Tee, Joseph; Andrews, Jason R; Ozcan, Aydogan
2017-06-01
AbstractSchistosomiasis affects over 170 million people in Africa. Here we compare a novel, low-cost mobile phone microscope to a conventional light microscope for the label-free diagnosis of Schistosoma haematobium infections in a rural Ghanaian school setting. We tested the performance of our handheld microscope using 60 slides that were randomly chosen from an ongoing epidemiologic study in school-aged children. The mobile phone microscope had a sensitivity of 72.1% (95% confidence interval [CI]: 56.1-84.2), specificity of 100% (95% CI: 75.9-100), positive predictive value of 100% (95% CI: 86.3-100), and a negative predictive value of 57.1% (95% CI: 37.4-75.0). With its modest sensitivity and high specificity, this handheld and cost-effective mobile phone-based microscope is a stepping-stone toward developing a powerful tool in clinical and public health settings where there is limited access to conventional laboratory diagnostic support.
Gram stain of pleural fluid ... mixing it with a violet stain (called a Gram stain). A laboratory specialist uses a microscope to ... reveals an abnormal collection of pleural fluid. The Gram stain can help identify the bacteria that might ...
Nishiyama, Hidetoshi; Suga, Mitsuo; Ogura, Toshihiko; Maruyama, Yuusuke; Koizumi, Mitsuru; Mio, Kazuhiro; Kitamura, Shinichi; Sato, Chikara
2010-11-01
Direct observation of subcellular structures and their characterization is essential for understanding their physiological functions. To observe them in open environment, we have developed an inverted scanning electron microscope with a detachable, open-culture dish, capable of 8 nm resolution, and combined with a fluorescence microscope quasi-simultaneously observing the same area from the top. For scanning electron microscopy from the bottom, a silicon nitride film window in the base of the dish maintains a vacuum between electron gun and open sample dish while allowing electrons to pass through. Electrons are backscattered from the sample and captured by a detector under the dish. Cells cultured on the open dish can be externally manipulated under optical microscopy, fixed, and observed using scanning electron microscopy. Once fine structures have been revealed by scanning electron microscopy, their component proteins may be identified by comparison with separately prepared fluorescence-labeled optical microscopic images of the candidate proteins, with their heavy-metal-labeled or stained ASEM images. Furthermore, cell nuclei in a tissue block stained with platinum-blue were successfully observed without thin-sectioning, which suggests the applicability of this inverted scanning electron microscope to cancer diagnosis. This microscope visualizes mesoscopic-scale structures, and is also applicable to non-bioscience fields including polymer chemistry. Copyright © 2010 Elsevier Inc. All rights reserved.
Vokes, David E.; Jackson, Ryan; Guo, Shuguang; Perez, Jorge A.; Su, Jianping; Ridgway, James M.; Armstrong, William B.; Chen, Zhongping; Wong, Brian J. F.
2014-01-01
Objectives Optical coherence tomography (OCT) is a new imaging modality that uses near-infrared light to produce cross-sectional images of tissue with a resolution approaching that of light microscopy. We have previously reported use of OCT imaging of the vocal folds (VFs) during direct laryngoscopy with a probe held in contact or near-contact with the VFs. This aim of this study was to develop and evaluate a novel OCT system integrated with a surgical microscope to allow hands-free OCT imaging of the VFs, which could be performed simultaneously with microscopic visualization. Methods We performed a prospective evaluation of a new method of acquiring OCT images of the VFs. Results An OCT system was successfully integrated with a surgical microscope to permit noncontact OCT imaging of the VFs of 10 patients. With this novel device we were able to identify VF epithelium and lamina propria; however, the resolution was reduced compared to that achieved with the standard contact or near-contact OCT. Conclusions Optical coherence tomography is able to produce high-resolution images of vocal fold mucosa to a maximum depth of 1.6 mm. It may be used in the diagnosis of VF lesions, particularly early squamous cell carcinoma, in which OCT can show disruption of the basement membrane. Mounting the OCT device directly onto the operating microscope allows hands-free noncontact OCT imaging and simultaneous conventional microscopic visualization of the VFs. However, the lateral resolution of the OCT microscope system is 50 µm, in contrast to the conventional handheld probe system (10 µm). Although such images at this resolution are still useful clinically, improved resolution would enhance the system’s performance, potentially enabling real-time OCT-guided microsurgery of the larynx. PMID:18700431
A comparison of microscopic ink characteristics of 35 commercially available surgical margin inks.
Milovancev, Milan; Löhr, Christiane V; Bildfell, Robert J; Gelberg, Howard B; Heidel, Jerry R; Valentine, Beth A
2013-11-01
To compare microscopic characteristics of commercially available surgical margin inks used for surgical pathology specimens. Prospective in vitro study. Thirty-five different surgical margin inks (black, blue, green, orange, red, violet, and yellow from 5 different manufacturers). Inks were applied to uniform, single-source, canine cadaveric full-thickness ventral abdominal tissue blocks. Tissue blocks and ink manufacturers were randomly paired and each color was applied to a length of the cut tissue margin. After drying, tissues were fixed in formalin, and 3 radial slices were obtained from each color section and processed for routine histologic evaluation, yielding 105 randomly numbered slides with each manufacturer's color represented in triplicate. Slides were evaluated by 5 blinded, board-certified veterinary anatomic pathologists using a standardized scoring scheme. Statistical analyses were performed to evaluate for ink manufacturer effects on scores, correlation among different subjective variables, and pathologist agreement. Black and blue had the most consistently high scores whereas red and violet had the most consistently low overall scores, across all manufacturers. All colors tested, except yellow, had statistically significant differences in overall scores among individual manufacturers. Overall score was significantly correlated to all other subjective microscopic scores evaluated. The average Spearman correlation coefficient among the 10 pairwise pathologists overall ink scores was 0.60. There are statistically significant differences in microscopic ink characteristics among manufacturers, with a notable degree of inter-pathologist agreement. © Copyright 2013 by The American College of Veterinary Surgeons.
Novel Concept of Attaching Endoscope Holder to Microscope for Two Handed Endoscopic Tympanoplasty.
Khan, Mubarak M; Parab, Sapna R
2016-06-01
The well established techniques in tympanoplasty are routinely performed with operating microscopes for many decades now. Endoscopic ear surgeries provide minimally invasive approach to the middle ear and evolving new science in the field of otology. The disadvantage of endoscopic ear surgeries is that it is one-handed surgical technique as the non-dominant left hand of the surgeon is utilized for holding and manipulating the endoscope. This necessitated the need for development of the endoscope holder which would allow both hands of surgeon to be free for surgical manipulation and also allow alternate use of microscope during tympanoplasty. To report the preliminary utility of our designed and developed endoscope holder attachment gripping to microscope for two handed technique of endoscopic tympanoplasty. Prospective Non Randomized Clinical Study. Our endoscope holder attachment for microscope was designed and developed to aid in endoscopic ear surgery and to overcome the disadvantage of single handed endoscopic surgery. It was tested for endoscopic Tympanoplasty. The design of the endoscope holder attachment is described in detail along with its manipulation and manoeuvreing. A total of 78 endoholder assisted type 1 endoscopic cartilage tympanoplasties were operated to evaluate its feasibility for the two handed technique and to evaluate the results of endoscopic type 1 cartilage tympanoplasty. In early follow up period ranging from 6 to 20 months, the graft uptake was seen in 76 ears with one residual perforation and 1 recurrent perforations giving a success rate of 97.435 %. Our endocsope holder attachment for gripping microscope is a good option for two handed technique in endoscopic type 1 cartilage tympanoplasty. The study reports the successful application and use of our endoscope holder attachment for gripping microscope in two handed technique of endoscopic type 1 cartilage tympanoplasty and comparable results with microscopic techniques. IV.
USDA-ARS?s Scientific Manuscript database
This study was designed to evaluate hyperspectral microscope images for early and rapid detection of Salmonella serotypes: S. Enteritidis, S. Heidelberg, S. Infantis, S. Kentucky, and S. Typhimurium at incubation times of 6, 8, 10, 12, and 24 hours. Images were collected by an acousto-optical tunab...
Quantitative phase tomography by using x-ray microscope with Foucault knife-edge scanning filter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Watanabe, Norio; Tsuburaya, Yuji; Shimada, Akihiro
2016-01-28
Quantitative phase tomography was evaluated by using a differential phase microscope with a Foucault knife-edge scanning filter. A 3D x-ray phase image of polystyrene beads was obtained at 5.4 keV. The reconstructed refractive index was fairly good agreement with the Henke’s tabulated data.
NASA Astrophysics Data System (ADS)
Santos, C.; Piedade, C.; Uggowitzer, P. J.; Montemor, M. F.; Carmezim, M. J.
2015-08-01
This work reports the one-step fabrication of a novel coating on ultra high purity magnesium using a parallel nano assembling process. The multifunctional biodegradable surface was obtained by adding hydroxyapatite nanoparticles (HapNP) plus graphene oxide (GO). The coating was characterized by scanning electron microscope (SEM), transmission electron microscope (TEM), X-ray diffractometer (XRD), micro-Raman spectroscopy. The thin phosphate coating (thickness of 1 μm) reveals a uniform coverage with cypress like structures. The incorporation of HapNP and GO promotes the hydrophilic behavior of the coating surface. The results revealed that the proposed coating can be used to tailor the surface properties such as wettability by adjusting the contents of HapNP and GO. The in vitro degradation rate of the coated magnesium suggests that the presence of HapNP and GO/HapNP in the phosphate coating decreased the current density compared to the single phosphate coating and uncoated magnesium. This study also reveals the HapNP/GO/phosphate coating induces apatite formation, showing suitable degradability that makes it a promising coating candidate for enhanced bone regeneration.
Crossover of Microscopic Dynamics in Metallic Supercooled Liquid Observed by NMR
NASA Astrophysics Data System (ADS)
Wu, Yue; Li, Lilong
2004-03-01
Nuclear magnetic resonance (NMR) is used to characterize local atomic motions in the glassy and supercooled liquid states of the bulk metallic glass system Pd_43Ni_10Cu_27P_20. It is shown that NMR is very effective in detecting local motions such as vibrations in metallic systems. The temperature dependence of the Knight shift reveals that certain local atomic motion decreases rapidly below a crossover temperature T_c. Above Tc as well as below the glass transition temperature Tg the mean-squared amplitude of local motions is shown to depend linearly on the temperature. The observed rapid decrease below Tc cannot be explained by heterogeneity effects. It reveals that qualitative changes of microscopic properties in the supercooled liquid take place at temperatures significantly above T_g. The observed phenomenon can be explained in terms of a rapid disappearance of certain local motions below Tc as suggested by the mode-coupling theory.
Zhang, Lingxin; Carpenter, Danielle; Dehner, Louis P
2016-01-01
A 30-year-old man with past medical history of atrial fibrillation/flutter passed away after presenting with sudden-onset cardiac dysfunction. The postmortem examination revealed cardiac tamponade secondary to rupture of a 7.2-cm pericardial perivascular epithelioid cell tumor (PEComa). The tumor grossly appeared to arise from the transverse pericardial sinus and focally penetrated the epicardium of the right atrium. Microscopically, it was composed of predominately spindle cells with low nuclear grade, no pleomorphism, or readily apparent mitoses. Immunohistochemistry revealed cytoplasmic reactivity for HMB-45, desmin, and smooth muscle actin. Electron microscopic findings were characterized by melanosome-like structures intermixed with intermediate filaments and abundant stacked endoplasmic reticulum. The present case is unique among previously reported pericardial/myocardial PEComas as a first example resulting in unexpected cardiac tamponade and sudden cardiac death. Copyright © 2016 Elsevier Inc. All rights reserved.
Amemiya, T; Nomura, S
1975-01-01
Clinical, laboratory and pathological findings of a patient in bronchial carcinoma with choroidal metastasis were presented. X-ray examination of the chest suggested the tumor shadow in the posterior segmental bronchus of the right upper lobe of the lung (r-B2b), while funduscopy and fluorescein angiography revealed the presence of choroidal tumor. ACTH levels in tumor tissues at autopsy and in serum were measured and definitely demonstrated and elevated. Histopathologically, the primary lesion was r-B2b and diagnosed as a mucocellular type of adenocarcinoma. The choroidal lesion was metastatic carcinoma. Electron microscopic examination of the choroidal lesion reembedded for electron microscopy from celloidin-embedded materials for light microscopy could reveal the presence of characteristic cytoplasmic granules referred to as neurosecretory-type granules. It is extremely rare that a hormone-producing metastatic carcinoma of the choroid from the bronchus has been proved.
[Persistence of the primordial vitreous body and buphthalmos].
Cernea, P; Simionescu, C; Bosun, I
1995-01-01
Persistence of the hyperplasic primordial vitreous body is determined by a deletion of embryonal development of the vitreous body and of the hyaloid vascular system. Infant aged 3.5 years presents persistence of primordial vitreous body with crystalline dislocation in the camera aquosa and secondary buphthalmos of the left eye and microphthalmos with dislocation of the crystalline in the vitreous body of the right eye. At the back of the right eye we noticed a whitish mass, richly vascularized with vestiges from the hyaloid artery, but the posterior half of the vitreous cavity is filled with microscopic blood; the fibrovascular membrane is made of conjunctive tissue set in parallel layers and vessels with macrolipophagic degeneration. Microscopic investigation of retina reveals glial hyperplasia zones in the neighbourhood of the vitreous body. In the present paper the authors show the persistence of the primordial vitreous body in the left eye and bilateral dislocation of the crystalline, revealing multiple ocular malformations.
Rheological and structural properties of sea cucumber Stichopus japonicus during heat treatment
NASA Astrophysics Data System (ADS)
Gao, Xin; Xue, Dongmei; Zhang, Zhaohui; Xu, Jiachao; Xue, Changhu
2005-07-01
Changes in tissue structure, rheological properties and water content of raw and heated sea cucumber meat were studied. Sea cucumber Stichopus japonicus was heated at 25°C , 70°C and 100°C water for 5 min. The structural changes were observed using a light microscope and the rheological parameters (rupture strength, adhesive strength and deformation) determined using a texture meter. Microscopic photograph revealed that the structural change of heated meat was greater than that of raw meat. The rupture strength, adhesive strength and deformation of raw meat were smaller than those of the heated meat. Meanwhile, rheological parameters showed positive correlation with heating temperature. These changes are mainly caused by thermal denaturation and gelatinization of collagen during heating. These changes were also evidenced in observations using a light microscope and differential scanning calorimetry.
Novel Starch-PVA Polymer for Microparticle Preparation and Optimization Using Factorial Design Study
Chattopadhyay, Helen; De, Amit Kumar; Datta, Sriparna
2015-01-01
The aim of our present work was to optimize the ratio of a very novel polymer, starch-polyvinyl alcohol (PVA), for controlled delivery of Ornidazole. Polymer-coated drug microparticles were prepared by emulsion method. Microscopic study, scanning electron microscopic study, and atomic force microscopic study revealed that the microparticles were within 10 micrometers of size with smooth spherical shape. The Fourier transform infrared spectroscopy showed absence of drug polymer interaction. A statistical 32 full factorial design was used to study the effect of different concentration of starch and PVA on the drug release profile. The three-dimensional plots gave us an idea about the contribution of each factor on the release kinetics. Hence this novel polymer of starch and polyvinyl alcohol can be utilized for control release of the drug from a targeted delivery device. PMID:27347511
The fatigue life study of polyphenylene sulfide composites filled with continuous glass fibers
NASA Astrophysics Data System (ADS)
Ye, Junjie; Hong, Yun; Wang, Yongkun; Zhai, Zhi; Shi, Baoquan; Chen, Xuefeng
2018-04-01
In this study, an effective microscopic model is proposed to investigate the fatigue life of composites containing continuous glass fibers, which is surrounded by polyphenylene sulfide (PPS) matrix materials. The representative volume element is discretized by parametric elements. Moreover, the microscopic model is established by employing the relation between average surface displacements and average surface tractions. Based on the experimental data, the required fatigue failure parameters of the PPS are determined. Two different fiber arrangements are considered for comparisons. Numerical analyses indicated that the square edge packing provides a more accuracy. In addition, microscopic structural parameters (fiber volume fraction, fiber off-axis angle) effect on the fatigue life of Glass/PPS composites is further discussed. It is revealed that fiber strength degradation effects on the fatigue life of continuous fiber-reinforced composites can be ignored.
Ferreira, Ricardo; Prado, Maíra; de Jesus Soares, Adriana; Zaia, Alexandre Augusto; de Souza-Filho, Francisco José
2015-08-01
The aim of the present study was to evaluate the influence of using a clinical microscope while performing mechanical cleaning of post space walls on the bond strength of a fiberglass post to dentin. Forty-five bovine roots were used. After preparation, roots were filled using gutta-percha and Pulp Canal Sealer (SybronEndo, Orange, CA). Subsequently, for post space preparation, the roots were divided into 3 groups: control (only heat condenser + specific bur of the post system); cleaning without a microscope, mechanical cleaning (after the procedure described in the control group, round burs were used to improve cleaning); and cleaning with a microscope, mechanical cleaning performed with round burs visualized under a clinical microscope. Then, fiberglass posts were cemented. The roots were prepared and evaluated by the push-out test. Data were analyzed using Kruskal-Wallis and Student-Newman-Keuls tests (P < .05). The failure pattern was classified as follows: adhesive between the cement and dentin, adhesive dentin/cement/post, mixed cohesive within dentin, mixed cohesive post, and mixed cohesive post/dentin. The bond strength values (mean ± standard deviation) were control (cervical 1.17 ± 1.1, middle 0.40 ± 0.3, apical 0.52 ± 0.3, and total 0.95 ± 1.9), cleaning without a microscope (cervical 1.66 ± 2.3, middle 0.65 ± 1.1, apical 0.79 ± 1.2, and total1.04 ± 1.7), and cleaning with a microscope (cervical 3.26 ± 2.8, middle 1.97 ± 3.5, apical 1.85 ± 4.1, and total 2.37 ± 3.5). In the cleaning with a microscope group, the bond strength values were significantly higher than those in the other groups. In all groups, the main failure pattern was adhesive between cement and dentin. The use of a clinical microscope while performing mechanical cleaning during post space preparation improved the bond strength of a fiberglass post to dentin. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Nielsen, Tommy Kjærgaard; Østraat, Øyvind; Graumann, Ole; Pedersen, Bodil Ginnerup; Andersen, Gratien; Høyer, Søren; Borre, Michael
2017-08-01
The present study investigates how computed tomography perfusion scans and magnetic resonance imaging correlates with the histopathological alterations in renal tissue after cryoablation. A total of 15 pigs were subjected to laparoscopic-assisted cryoablation on both kidneys. After intervention, each animal was randomized to a postoperative follow-up period of 1, 2, or 4 weeks, after which computed tomography perfusion and magnetic resonance imaging scans were performed. Immediately after imaging, open bilateral nephrectomy was performed allowing for histopathological examination of the cryolesions. On computed tomography perfusion and magnetic resonance imaging examinations, rim enhancement was observed in the transition zone of the cryolesion 1week after laparoscopic-assisted cryoablation. This rim enhancement was found to subside after 2 and 4 weeks of follow-up, which was consistent with the microscopic examinations revealing of fibrotic scar tissue formation in the peripheral zone of the cryolesion. On T2 magnetic resonance imaging sequences, a thin hypointense rim surrounded the cryolesion, separating it from the adjacent renal parenchyma. Microscopic examinations revealed hemorrhage and later hemosiderin located in the peripheral zone. No nodular or diffuse contrast enhancement was found in the central zone of the cryolesions at any follow-up stage on neither computed tomography perfusion nor magnetic resonance imaging. On microscopic examinations, the central zone was found to consist of coagulative necrosis 1 week after laparoscopic-assisted cryoablation, which was partially replaced by fibrotic scar tissue 4 weeks following laparoscopic-assisted cryoablation. Both computed tomography perfusion and magnetic resonance imaging found the renal collecting system to be involved at all 3 stages of follow-up, but on microscopic examination, the urothelium was found to be intact in all cases. In conclusion, cryoablation effectively destroyed renal parenchyma, leaving the urothelium intact. Both computed tomography perfusion and magnetic resonance imaging reflect the microscopic findings but with some differences, especially regarding the peripheral zone. Magnetic resonance imaging seems an attractive modality for early postoperative follow-up.
NASA Astrophysics Data System (ADS)
Cisek, Richard
Physical and functional properties of advanced nano-composite materials and biological structures are determined by self-organized atoms and molecules into nanostructures and in turn by microscopic organization of the nanostructures into assemblies of higher structural complexity. Therefore, microscopes are indispensable tools for structural investigations at various levels of organization. In this work, novel nonlinear optical microscopy methods were developed to non-invasively study structural organization at the nanoscopic and microscopic levels. Atomic organization of semiconductor nanowires, molecular organization of amylose biocrystallites in starch granules, and microscopic organization of several photosynthetic organisms was elucidated. The structure of ZnSe nanowires, key components in many modern nanodevices, was investigated using polarization harmonic generation microscopy. Based on nonlinear optical properties of the different crystal lattices, zinc blende and wurtzite nanowires were differentiated, and the three-dimensional orientation of the zinc blende nanowires could be found. The structure of starch granules, a model biocrystal, important in food as well as health sciences, was also investigated using polarization harmonic microscopy. The study was combined with ab initio calculations using the crystal structures of amylose A and B, revealing that second harmonic signals originate from the hydroxide and hydrogen bonds in the starch granules. Visualization of several photosynthetic organisms including the green algae, Chlamydomonas reinhardtii, two species of cyanobacteria, Leptolyngbya sp. and Anabaena sp., aggregates of light-harvesting pigment-protein complexes as well as chloroplasts from green plants were also explored, revealing that future nonlinear microscopy applications could include structural studies of cell walls, the Chlamydomonas eyespot, and photosynthetic membranes. In this study, several nonlinear optical microscopy modalities were developed for quantitative structural investigations of nano and micro-sized architectures. Non-invasive extraction of crystallographic information in microscopic samples will have a number of potential benefits, for example, in clinical applications, allowing observations of disease states inside tissues without the need for biopsy. Industrial nanotechnology will benefit from fast determination of nanostructures with nonlinear microscopy that will improve quality of nanodevices.
Mitra, Shouvik; Patra, Prasun; Pradhan, Saheli; Debnath, Nitai; Dey, Kushal Kumar; Sarkar, Sampad; Chattopadhyay, Dhrubajyoti; Goswami, Arunava
2015-04-15
A simple chemical method has been devised for deliberate incorporation of zinc oxide nanoparticles (ZNPs) within mesoporous nanosilica (mSiO2) matrix to yield zinc oxide nanoparticles embedded in mesoporous nanosilica (ZnO@mSiO2). ZnO@mSiO2 inhibited the growth of four strains of fungi in a dose dependant manner. A series of biochemical assays revealed generation of oxidative stress from ZnO@mSiO2 for such biocidal response. We proposed transient superoxide and its subsequent conversion to H2O2 played a pivotal role behind such biocidal response as revealed from our systematic evaluation. This resulted morphological alteration of fungi through increase in number of facets, in correlation we found up-regulation in oxidative stress related genes. Bioavailability within the fungal sample was confirmed from microscopic, spectroscopic, biophysical techniques. Protein carbonylation of fungal species was the chemical outcome of such above mentioned stress and quantified by high performance liquid chromatography (HPLC) via subsequent hydrazone derivatization. Several in vitro and in vivo evaluations revealed the biocompatibility of ZnO@mSiO2. Altogether this report claims a new biocidal agent with a detailed mode of action focusing on the origin and quantification of oxidative stress through biophysical and biochemical techniques for the first time for real time applications. Copyright © 2014 Elsevier Inc. All rights reserved.
Kho, Steven; Marfurt, Jutta; Handayuni, Irene; Pava, Zuleima; Noviyanti, Rintis; Kusuma, Andreas; Piera, Kim A; Burdam, Faustina H; Kenangalem, Enny; Lampah, Daniel A; Engwerda, Christian R; Poespoprodjo, Jeanne R; Price, Ric N; Anstey, Nicholas M; Minigo, Gabriela; Woodberry, Tonia
2016-06-21
Plasmodium falciparum and Plasmodium vivax infections compromise dendritic cell (DC) function and expand regulatory T (Treg) cells in both clinical disease (malaria) and experimental human sub-microscopic infection. Conversely, in asymptomatic microscopy-positive (patent) P. falciparum or P. vivax infection in endemic areas, blood DC increase or retain HLA-DR expression and Treg cells exhibit reduced activation, suggesting that DC and Treg cells contribute to the control of patent asymptomatic infection. The effect of sub-microscopic (sub-patent) asymptomatic Plasmodium infection on DC and Treg cells in malaria-endemic area residents remains unclear. In a cross-sectional household survey conducted in Papua, Indonesia, 162 asymptomatic adults were prospectively evaluated for DC and Treg cells using field-based flow cytometry. Of these, 161 individuals (99 %) were assessed retrospectively by polymerase chain reaction (PCR), 19 of whom had sub-microscopic infection with P. falciparum and 15 with sub-microscopic P. vivax infection. Flow cytometric data were re-analysed after re-grouping asymptomatic individuals according to PCR results into negative controls, sub-microscopic and microscopic parasitaemia to examine DC and Treg cell phenotype in sub-microscopic infection. Asymptomatic adults with sub-microscopic P. falciparum or P. vivax infection had DC HLA-DR expression and Treg cell activation comparable to PCR-negative controls. Sub-microscopic P. falciparum infection was associated with lower peripheral CD4(+) T cells and lymphocytes, however sub-microscopic Plasmodium infection had no apparent effect on DC sub-set number or Treg cell frequency. In contrast to the impairment of DC maturation/function and the activation of Treg cells seen with sub-microscopic parasitaemia in primary experimental human Plasmodium infection, no phenotypic evidence of dysregulation of DC and Treg cells was observed in asymptomatic sub-microscopic Plasmodium infection in Indonesian adults. This is consistent with DC and Treg cells retaining their functional capacity in sub-microscopic asymptomatic infection with P. falciparum or P. vivax in malaria-endemic areas.
NASA Astrophysics Data System (ADS)
Wang, J.; Guo, J. P.; Yi, J. J.; Huang, Q. G.; Li, H. M.; Li, Y. F.; Gao, K. J.; Yang, W. T.
2014-08-01
This paper reports the preparation of coral-shaped topological morphology nascent polyethylene (PE) particles promoted by the novel heterogeneous non-metallocene catalyst (m-CH3PhO)TiCl3/carbon nanotubes (CNTs), with AlEt3 used as a cocatalyst. Scanning electron microscope (SEM), high resolution transmission electron microscope (HR-TEM) and inductively coupled plasma (ICP) emission spectroscopy were used to determine the morphology of the catalyst particles and the content of (m-CH3PhO)TiCl3. The carbon nanotube surface was treated with Grignard Reagent prior to reacting with (m-CH3PhO)TiCl3. The catalyst system could effectively catalyze ethylene polymerization and ethylene with 1- hexene copolymerization, the catalytic activity could reach up to 5.8 kg/((gTi)h). Morphology of the obtained polymer particles by SEM and HR-TEM technique revealed that the nascent polyethylene particles looked like coral shape in micro-size. The multiwalled carbon nanotubes (MWCNTs) supported catalysts polymerized ethylene to form polymer nanocomposite in situ. The microscopic examination of this nanocomposite revealed that carbon nanoparticles in PE matrix had a good distribution and the cryogenically fractured surface was ductile-like when polymerization time was 2 min.
Silicone intraocular lens surface calcification in a patient with asteroid hyalosis.
Matsumura, Kazuhiro; Takano, Masahiko; Shimizu, Kimiya; Nemoto, Noriko
2012-07-01
To confirm a substance presence on the posterior intraocular lens (IOL) surface in a patient with asteroid hyalosis. An 80-year-old man had IOLs for approximately 12 years. Opacities and neodymium-doped yttrium aluminum garnet pits were observed on the posterior surface of the right IOL. Asteroid hyalosis and an epiretinal membrane were observed OD. An IOL exchange was performed on 24 March 2008, and the explanted IOL was analyzed using a light microscope and a transmission electron microscope with a scanning electron micrograph and an energy-dispersive X-ray spectrometer for elemental analysis. To confirm asteroid hyalosis, asteroid bodies were examined with the ionic liquid (EtMeIm+ BF4-) method using a field emission scanning electron microscope (FE-SEM) with digital beam control RGB mapping. X-ray spectrometry of the deposits revealed high calcium and phosphorus peaks. Spectrometry revealed that the posterior IOL surface opacity was due to a calcium-phosphorus compound. Examination of the asteroid bodies using FE-SEM with digital beam control RGB mapping confirmed calcium and phosphorus as the main components. Calcium hydrogen phosphate dihydrate deposits were probably responsible for the posterior IOL surface opacity. Furthermore, analysis of the asteroid bodies demonstrated that calcium and phosphorus were its main components.
Visualizing chemical functionality in plant cell walls
Zeng, Yining; Himmel, Michael E.; Ding, Shi-You
2017-11-30
Understanding plant cell wall cross-linking chemistry and polymeric architecture is key to the efficient utilization of biomass in all prospects from rational genetic modification to downstream chemical and biological conversion to produce fuels and value chemicals. In fact, the bulk properties of cell wall recalcitrance are collectively determined by its chemical features over a wide range of length scales from tissue, cellular to polymeric architectures. Microscopic visualization of cell walls from the nanometer to the micrometer scale offers an in situ approach to study their chemical functionality considering its spatial and chemical complexity, particularly the capabilities of characterizing biomass non-destructivelymore » and in real-time during conversion processes. Microscopic characterization has revealed heterogeneity in the distribution of chemical features, which would otherwise be hidden in bulk analysis. Key microscopic features include cell wall type, wall layering, and wall composition - especially cellulose and lignin distributions. Microscopic tools, such as atomic force microscopy, stimulated Raman scattering microscopy, and fluorescence microscopy, have been applied to investigations of cell wall structure and chemistry from the native wall to wall treated by thermal chemical pretreatment and enzymatic hydrolysis. While advancing our current understanding of plant cell wall recalcitrance and deconstruction, microscopic tools with improved spatial resolution will steadily enhance our fundamental understanding of cell wall function.« less
Visualizing chemical functionality in plant cell walls
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zeng, Yining; Himmel, Michael E.; Ding, Shi-You
Understanding plant cell wall cross-linking chemistry and polymeric architecture is key to the efficient utilization of biomass in all prospects from rational genetic modification to downstream chemical and biological conversion to produce fuels and value chemicals. In fact, the bulk properties of cell wall recalcitrance are collectively determined by its chemical features over a wide range of length scales from tissue, cellular to polymeric architectures. Microscopic visualization of cell walls from the nanometer to the micrometer scale offers an in situ approach to study their chemical functionality considering its spatial and chemical complexity, particularly the capabilities of characterizing biomass non-destructivelymore » and in real-time during conversion processes. Microscopic characterization has revealed heterogeneity in the distribution of chemical features, which would otherwise be hidden in bulk analysis. Key microscopic features include cell wall type, wall layering, and wall composition - especially cellulose and lignin distributions. Microscopic tools, such as atomic force microscopy, stimulated Raman scattering microscopy, and fluorescence microscopy, have been applied to investigations of cell wall structure and chemistry from the native wall to wall treated by thermal chemical pretreatment and enzymatic hydrolysis. While advancing our current understanding of plant cell wall recalcitrance and deconstruction, microscopic tools with improved spatial resolution will steadily enhance our fundamental understanding of cell wall function.« less
Visualizing chemical functionality in plant cell walls.
Zeng, Yining; Himmel, Michael E; Ding, Shi-You
2017-01-01
Understanding plant cell wall cross-linking chemistry and polymeric architecture is key to the efficient utilization of biomass in all prospects from rational genetic modification to downstream chemical and biological conversion to produce fuels and value chemicals. In fact, the bulk properties of cell wall recalcitrance are collectively determined by its chemical features over a wide range of length scales from tissue, cellular to polymeric architectures. Microscopic visualization of cell walls from the nanometer to the micrometer scale offers an in situ approach to study their chemical functionality considering its spatial and chemical complexity, particularly the capabilities of characterizing biomass non-destructively and in real-time during conversion processes. Microscopic characterization has revealed heterogeneity in the distribution of chemical features, which would otherwise be hidden in bulk analysis. Key microscopic features include cell wall type, wall layering, and wall composition-especially cellulose and lignin distributions. Microscopic tools, such as atomic force microscopy, stimulated Raman scattering microscopy, and fluorescence microscopy, have been applied to investigations of cell wall structure and chemistry from the native wall to wall treated by thermal chemical pretreatment and enzymatic hydrolysis. While advancing our current understanding of plant cell wall recalcitrance and deconstruction, microscopic tools with improved spatial resolution will steadily enhance our fundamental understanding of cell wall function.
Ximenes, Marcos; Triches, Thaisa C; Beltrame, Ana Paula C A; Hilgert, Leandro A; Cardoso, Mariane
2013-01-01
This study evaluated the efficacy of 2 final irrigation solutions for removal of the smear layer (SL) from root canals of primary teeth, using scanning electron microscope (SEM) analysis. Thirty primary molars were selected and a single operator instrumented the canals. The initial irrigation was done with a 1% sodium hypochlorite (NaOCl) solution. After the preparation, the roots were randomly divided into 3 groups for final irrigation: Group 1, 1% NaOCl (n = 10); Group 2, 17% EDTA + 1% NaOCl (n = 10); and Group 3, 17% EDTA + saline solution (n = 10). The roots were prepared for SEM analysis (magnification 1000X). The photomicrographs were independently analyzed by 2 investigators with SEM experience, attributing scores to each root third in terms of SL removal. Kruskal-Wallis and Mann-Whitney tests revealed that there was no statistical difference between the groups (P = 0.489). However, a statistical difference was found (P < 0.05) in a comparison of root thirds, with the apical third having the worst results. Comparing the thirds within the same group, all canals showed statistical differences between the cervical and apical thirds (P < 0.05). The authors determined that no substance or association of substances were able to completely remove SL.
Laistler, Elmar; Poirier-Quinot, Marie; Lambert, Simon A; Dubuisson, Rose-Marie; Girard, Olivier M; Moser, Ewald; Darrasse, Luc; Ginefri, Jean-Christophe
2015-02-01
To demonstrate the feasibility of a highly sensitive superconducting surface coil for microscopic MRI of the human skin in vivo in a clinical 1.5 Tesla (T) scanner. A 12.4-mm high-temperature superconducting coil was used at 1.5T for phantom and in vivo skin imaging. Images were inspected to identify fine anatomical skin structures. Signal-to-noise ratio (SNR) improvement by the high-temperature superconducting (HTS) coil, as compared to a commercial MR microscopy coil was quantified from phantom imaging; the gain over a geometrically identical coil made from copper (cooled or not) was theoretically deduced. Noise sources were identified to evaluate the potential of HTS coils for future studies. In vivo skin images with isotropic 80 μm resolution were demonstrated revealing fine anatomical structures. The HTS coil improved SNR by a factor 32 over the reference coil in a nonloading phantom. For calf imaging, SNR gains of 380% and 30% can be expected over an identical copper coil at room temperature and 77 K, respectively. The high sensitivity of HTS coils allows for microscopic imaging of the skin at 1.5T and could serve as a tool for dermatology in a clinical setting. © 2013 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Gangarapu, Manjari; Sarangapany, Saran; Suja, Devipriya P.; Arava, Vijaya Bhaskara Rao
2018-04-01
In this study, synthesis of Ag-Cu alloy bimetal nanoparticles anchored on high surface and porous ZnO using a facile, greener and low-cost aqeous bark extract of Aglaia roxburghiana for highly active, ultra-rapid and stable catalyst is performed. The nanocomposite was scrupulously characterized using UV-Vis spectrophotometer, X-ray diffraction, Raman spectrophotometer, high-resolution transmission electron microscope, selected area (electron) diffraction, scanning electron microscope with energy dispersive X-ray spectroscopy, and Fourier-transform infrared spectroscopy. The catalytic activity of the green synthesized Ag-Cu bimetal nanocomposite was evaluated in the reduction of 4-nitrophenol (4-NP), methylene blue (MB) and rhodamine B (Rh B) dyes. The different types of dye exhibited very high and effective catalytic activity within few seconds. The theoretical investigations reveal that the unique synergistic effect of Ag-Cu nanoparticles and immobilization over ZnO assists in the reduction of 4-NP, MB and Rh B. Loading and leaching of metal nanoparticles were obtained using inductively coupled plasma atomic emission spectroscopy. Moreover, the stable and efficient recyclability of nanocomposite by centrifugation after completion of the reaction was demonstrated. The results lead to the design different possible bimetal on ZnO with boosting and an effective catalyst for the environmental applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cho, Kyung J.; Cho, David R.
Purpose: To evaluate the safety and the effectiveness of CO{sub 2} splenoportography with the 'skinny' needle. Methods: A flexible, 22 gauge needle ('skinny' needle) was introduced into the exteriorized spleens of five pigs. After checking the intrasplenic positioning withCO{sub 2} injection, increasing doses of CO{sub 2} (10-60cm{sup 3}) were injected using a dedicated CO{sub 2}injector with digital imaging. The puncture sites were observed during and after CO{sub 2} injections, and after removal of the needle.The spleens were then removed for gross and microscopic examination. Results: In all animals digital subtractionCO{sub 2} splenoportograms showed the splenic, extra- and intrahepatic portal veins,more » and the most distal portion of the superiormesenteric vein. No CO{sub 2} extravasation occurred in the spleen. There was no significant bleeding from the puncture site after removal of the needle. Gross and microscopic examination revealed no evidence of splenic rupture or intrasplenic hematoma. Conclusion: CO{sub 2} splenoportography with the 'skinny' needle is a safe and simple method of visualizing the portal vein and its branches. Careful appraisals of the clinical usefulness of the method will be needed in various clinical settings.« less
Swimming Motility Reduces Deposition to Silica Surfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Nanxi; Massoudieh, Arash; Liang, Xiaomeng
The role of swimming motility on bacterial transport and fate in porous media was evaluated. We present microscopic evidence showing that strong swimming motility reduces attachment of Azotobacter vinelandii cells to silica surfaces. Applying global and cluster statistical analyses to microscopic videos taken under non-flow conditions, wild type, flagellated A. vinelandii strain DJ showed strong swimming ability with an average speed of 13.1 μm/s, DJ77 showed impaired swimming averaged at 8.7 μm/s, and both the non-flagellated JZ52 and chemically treated DJ cells were non-motile. Quantitative analyses of trajectories observed at different distances above the collector of a radial stagnation pointmore » flow cell (RSPF) revealed that both swimming and non-swimming cells moved with the flow when at a distance of at least 20 μm from the collector surface. Near the surface, DJ cells showed both horizontal and vertical movement diverging them from reaching surfaces, while chemically treated DJ cells moved with the flow to reach surfaces, suggesting that strong swimming reduced attachment. In agreement with the RSPF results, the deposition rates obtained for two-dimensional multiple-collector micromodels were also lowest for DJ, while DJ77 and JZ52 showed similar values. Strong swimming specifically reduced deposition on the upstream surfaces of the micromodel collectors.« less
Gorji, Mohammad Saleh; Razak, Khairunisak Abdul; Cheong, Kuan Yew
2013-10-15
Given the enormous importance of Au nanoparticles (NPs) deposition on Si substrates as the precursor for various applications, we present an alternative approach to deposit Au NPs on linker-free n- and p-type Si substrates. It is demonstrated that, all conditions being similar, there is a significant difference between densities of the deposited NPs on both substrates. The Zeta-potential and polarity of charges surrounding the hydroxylamine reduced seeded growth Au NPs, are determined by a Zetasizer. To investigate the surface properties of Si substrates, contact angle measurement is performed. Field-emission scanning electron microscope is then utilized to distinguish the NPs density on the substrates. Finally, Al/Si Schottky barrier diodes with embedded Au NPs are fabricated, and their structural and electrical characteristics are further evaluated using an energy-filtered transmission electron microscope and current-voltage measurements, respectively. The results reveal that the density of NPs is significantly higher on n-type Si substrate and consequently has more pronounced effects on the electrical characteristics of the diode. It is concluded that protonation of Si-OH group on Si surface in low pH is responsible for the immobilization of Au NPs, which eventually contributes to the lowering of barrier height and enhances the electrical characteristics. Copyright © 2013 Elsevier Inc. All rights reserved.
Changes Induced by Exposure of the Human Lung to Glass Fiber–Reinforced Plastic
Abbate, Carmelo; Giorgianni, Concetto; Brecciaroli, Renato; Giacobbe, Giovanni; Costa, Chiara; Cavallari, Vittorio; Albiero, Francesca; Catania, Stefania; Tringali, Maria Antonietta; Martino, Lucia Barbaro; Abbate, Simona
2006-01-01
The inhalation of glass dusts mixed in resin, generally known as glass fiber–reinforced plastic (GRP), represents a little-studied occupational hazard. The few studies performed have highlighted nonspecific lung disorders in animals and in humans. In the present study we evaluated the alteration of the respiratory system and the pathogenic mechanisms causing the changes in a group of working men employed in different GRP processing operations and exposed to production dusts. The study was conducted on a sample of 29 male subjects whose mean age was 37 years and mean length of service 11 years. All of the subjects were submitted to a clinical check-up, basic tests, and bronchoalveolar lavage (BAL); microscopic studies and biochemical analysis were performed on the BAL fluid. Tests of respiratory function showed a large number of obstructive syndromes; scanning electron microscopy highlighted qualitative and quantitative alterations of the alveolar macrophages; and transmission electron microscopy revealed the presence of electron-dense cytoplasmatic inclusions indicating intense and active phlogosis (external inflammation). Biochemical analyses highlighted an increase in protein content associated with alterations of the lung oxidant/antioxidant homeostasis. Inhalation of GRP, independent of environmental concentration, causes alterations of the cellular and humoral components of pulmonary interstitium; these alterations are identified microscopically as acute alveolitis. PMID:17107859
Paulkumar, Kanniah; Gnanajobitha, Gnanadhas; Vanaja, Mahendran; Rajeshkumar, Shanmugam; Malarkodi, Chelladurai; Pandian, Kannaiyan; Annadurai, Gurusamy
2014-01-01
Utilization of biological materials in synthesis of nanoparticles is one of the hottest topics in modern nanoscience and nanotechnology. In the present investigation, the silver nanoparticles were synthesized by using the leaf and stem extract of Piper nigrum. The synthesized nanoparticle was characterized by UV-vis spectroscopy, X-ray diffraction (XRD), scanning electron microscope (SEM), transmission electron microscope (TEM), energy dispersive X-ray analysis (EDAX), and Fourier Transform Infrared Spectroscopy (FTIR). The observation of the peak at 460 nm in the UV-vis spectra for leaf- and stem-synthesized silver nanoparticles reveals the reduction of silver metal ions into silver nanoparticles. Further, XRD analysis has been carried out to confirm the crystalline nature of the synthesized silver nanoparticles. The TEM images show that the leaf- and stem-synthesized silver nanoparticles were within the size of about 7–50 nm and 9–30 nm, respectively. The FTIR analysis was performed to identify the possible functional groups involved in the synthesis of silver nanoparticles. Further, the antibacterial activity of the green-synthesized silver nanoparticles was examined against agricultural plant pathogens. The antibacterial property of silver nanoparticles is a beneficial application in the field of agricultural nanotechnology. PMID:24558336
NASA Astrophysics Data System (ADS)
Abbaslou, Reza Malek; Vosoughi, Vahid; Dalai, Ajay K.
2017-10-01
Carbon nanotubes (CNTs) are different from other porous substrates such as activated carbon due to their high external surfaces. This structural feature can lead in some uncertainties in the results of nitrogen adsorption analysis for characterization of CNTs. In this paper, the results of microscopic analyses and nitrogen adsorption method for characterization of carbon nanotubes were compared. Five different types of CNTs with different structures were either synthesized or purchased. The CNT samples were characterized by high resolution transmission electron microscopy (HRTEM), scanning electron microscopy (SEM) and N2 adsorption analysis. The comparisons between the results from the microscopic analyses and N2 adsorption showed that the total pore volume and BET surface measurements include the internal and external porosity of CNTs. Therefore, the interpretation of N2 adsorption data required accurate TEM analysis. In addition, the evaluation of pore size distribution curves from all CNT samples in this study and several instances in the literature revealed the presence of a common peak in the range of 2-5 nm. This peak does not explain the inner pore size distribution. The presence of this common peak can be attributed to the strong adsorption of N2 on the junction of touched and crossed nanotubes.
Bio-reinforced self-healing concrete using magnetic iron oxide nanoparticles.
Seifan, Mostafa; Sarmah, Ajit K; Ebrahiminezhad, Alireza; Ghasemi, Younes; Samani, Ali Khajeh; Berenjian, Aydin
2018-03-01
Immobilization has been reported as an efficient technique to address the bacterial vulnerability for application in bio self-healing concrete. In this study, for the first time, magnetic iron oxide nanoparticles (IONs) are being practically employed as the protective vehicle for bacteria to evaluate the self-healing performance in concrete environment. Magnetic IONs were successfully synthesized and characterized using different techniques. The scanning electron microscope (SEM) images show the efficient adsorption of nanoparticles to the Bacillus cells. Microscopic observation illustrates that the incorporation of the immobilized bacteria in the concrete matrix resulted in a significant crack healing behavior, while the control specimen had no healing characteristics. Analysis of bio-precipitates revealed that the induced minerals in the cracks were calcium carbonate. The effect of magnetic immobilized cells on the concrete water absorption showed that the concrete specimens supplemented with decorated bacteria with IONs had a higher resistance to water penetration. The initial and secondary water absorption rates in bio-concrete specimens were 26% and 22% lower than the control specimens. Due to the compatible behavior of IONs with the concrete compositions, the results of this study proved the potential application of IONs for developing a new generation of bio self-healing concrete.
Cytotoxicity of 45S5 bioglass paste used for dentine hypersensitivity treatment.
Bakry, Ahmed Samir; Tamura, Yukihiko; Otsuki, Masayuki; Kasugai, Shohei; Ohya, Keiichi; Tagami, Junji
2011-09-01
45S5 bioglass mixed with 50% phosphoric acid has been suggested to treat dentine hypersensitivity and incipient enamel caries. This study is going to evaluate the biocompatibility of using the aforementioned technique with the rat pulpal cells. The relative cytotoxicity of 45S5 bioglass on rat dental pulp cells was compared to the cytotoxicity of a temporary filling material (Caviton; GC, Japan), Type 1 glass ionomer cement (Fuji I; GC, Tokyo, Japan) and commercial desensitising agent (SuperSeal; Phoenix Dental, Fenton, MI, USA) using a transwell insert model. Cell viability was measured by means of a 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay. The number of viable cell counts were compared using one way ANOVA (p<0.05). The morphological alterations of the pulp cells were observed directly by phase contrast microscope. The results of this study indicated that cell viability recorded by the 45S5 bioglass paste group did not differ significantly from those of the Caviton, glass ionomer or superseal, moreover pulpal cells microscopic analysis revealed that 45S5 bioglass elicited minimal toxic effect. 45S5 bioglass paste can serve as a biocompatible material that can potentially be used safely on dentine. Copyright © 2011 Elsevier Ltd. All rights reserved.
Effects of hydrogen peroxide on the light reflectance and morphology of bovine enamel.
Kwon, Y H; Huo, M S; Kim, K H; Kim, S K; Kim, Y J
2002-05-01
The purpose of this study was to examine the effects of a bleaching agent (30% hydrogen peroxide) on the surface of bovine enamel using a scanning electron microscope and a UV-VIS-NIR spectrophotometer. Five non-carious bovine incisors were bleached for 0, 1, 2 and 3 days using 30% hydrogen peroxide. The light reflectance spectrum was measured using a spectrophotometer with diffuse reflectance mode. Colour values and colour differences in the teeth were evaluated from the reflectance measurements with the CIE L*a*b* colour coordinate system. Surface alterations in the bleached and unbleached teeth were studied using a scanning electron microscope. The change of reflectance in the teeth was related to the change of colour. Most reflectance change occurred within a 1-day bleaching, and this result was confirmed by a CIE L*a*b* colour coordinate system. The colour differences in the bleached teeth were significant enough to be perceived by the observer's eye. The comparison of bleached to unbleached bovine enamel revealed that the bleached surface showed non-uniform slight morphological alterations, and it developed varying degrees of surface porosity. This study indicates that the bleached bovine teeth showed apparent colour differences as well as slight morphological alterations after bleaching.
Evaluation of criteria for the postmortem diagnosis of mycoplasmal pneumonia of swine.
Armstrong, C H; Scheidt, A B; Thacker, H L; Runnels, L J; Freeman, M J
1984-01-01
Ten swine from each of five herds believed to be affected with mycoplasmal pneumonia of swine and ten swine from each of five herds believed to be mycoplasmal pneumonia-free were selected for postmortem study. Lungs from the 100 swine were examined; grossly and microscopically for lesions typical of mycoplasmal pneumonia of swine and culturally and by an indirect immunofluorescent procedure for the presence of Mycoplasma hyopneumoniae. Nineteen of the lungs had both gross and microscopic lesions typical of mycoplasmal pneumonia of swine and 13 (68%) of these were infected, i.e. were culturally and/or indirect immunofluorescent positive. Absence of gross lesions did not prove freedom from mycoplasmal pneumonia, 14 of 73 (19%) grossly normal lungs were found to be infected with M. hyopneumoniae. Comparison of the indirect immunofluorescent and cultural examination, as methods of diagnosing mycoplasma pneumonia, revealed that neither procedure alone was reliable in the case of negative results. Ten lungs were indirect immunofluorescent negative and culturally positive and seven were culturally negative and indirect immunofluorescent positive (11 lungs were positive by both procedures). It was concluded that a definitive diagnosis of mycoplasmal pneumonia of swine requires that M. hyopneumoniae be visualized in indirect immunofluorescent stained lung sections or that it be recovered culturally. PMID:6434167
Deng, Yun; Hajilou, Tarlan; Barnoush, Afrooz
2017-07-28
To evaluate the hydrogen (H)-induced embrittlement in iron aluminium intermetallics, especially the one with stoichiometric composition of 50 at.% Al, a novel in situ micro-cantilever bending test was applied within an environmental scanning electron microscope (ESEM), which provides both a full process monitoring and a clean, in situ H-charging condition. Two sets of cantilevers were analysed in this work: one set of un-notched cantilevers, and the other set with focused ion beam-milled notch laying on two crystallographic planes: (010) and (110). The cantilevers were tested under two environmental conditions: vacuum (approximately 5 × 10 -4 Pa) and ESEM (450 Pa water vapour). Crack initiation at stress-concentrated locations and propagation to cause catastrophic failure were observed when cantilevers were tested in the presence of H; while no cracking occurred when tested in vacuum. Both the bending strength for un-notched beams and the fracture toughness for notched beams were reduced under H exposure. The hydrogen embrittlement (HE) susceptibility was found to be orientation dependent: the (010) crystallographic plane was more fragile to HE than the (110) plane.This article is part of the themed issue 'The challenges of hydrogen and metals'. © 2017 The Author(s).
Changes induced by exposure of the human lung to glass fiber-reinforced plastic.
Abbate, Carmelo; Giorgianni, Concetto; Brecciaroli, Renato; Giacobbe, Giovanni; Costa, Chiara; Cavallari, Vittorio; Albiero, Francesca; Catania, Stefania; Tringali, Maria Antonietta; Martino, Lucia Barbaro; Abbate, Simona
2006-11-01
The inhalation of glass dusts mixed in resin, generally known as glass fiber-reinforced plastic (GRP), represents a little-studied occupational hazard. The few studies performed have highlighted nonspecific lung disorders in animals and in humans. In the present study we evaluated the alteration of the respiratory system and the pathogenic mechanisms causing the changes in a group of working men employed in different GRP processing operations and exposed to production dusts. The study was conducted on a sample of 29 male subjects whose mean age was 37 years and mean length of service 11 years. All of the subjects were submitted to a clinical check-up, basic tests, and bronchoalveolar lavage (BAL); microscopic studies and biochemical analysis were performed on the BAL fluid. Tests of respiratory function showed a large number of obstructive syndromes; scanning electron microscopy highlighted qualitative and quantitative alterations of the alveolar macrophages; and transmission electron microscopy revealed the presence of electron-dense cytoplasmatic inclusions indicating intense and active phlogosis (external inflammation). Biochemical analyses highlighted an increase in protein content associated with alterations of the lung oxidant/antioxidant homeostasis. Inhalation of GRP, independent of environmental concentration, causes alterations of the cellular and humoral components of pulmonary interstitium; these alterations are identified microscopically as acute alveolitis.
Wang, Fang; Sun, Ying; Cao, Meng; Nishi, Ryuji
2016-04-01
This study investigates the influence of structure depth on image blurring of micrometres-thick films by experiment and simulation with a conventional transmission electron microscope (TEM). First, ultra-high-voltage electron microscope (ultra-HVEM) images of nanometer gold particles embedded in thick epoxy-resin films were acquired in the experiment and compared with simulated images. Then, variations of image blurring of gold particles at different depths were evaluated by calculating the particle diameter. The results showed that with a decrease in depth, image blurring increased. This depth-related property was more apparent for thicker specimens. Fortunately, larger particle depth involves less image blurring, even for a 10-μm-thick epoxy-resin film. The quality dependence on depth of a 3D reconstruction of particle structures in thick specimens was revealed by electron tomography. The evolution of image blurring with structure depth is determined mainly by multiple elastic scattering effects. Thick specimens of heavier materials produced more blurring due to a larger lateral spread of electrons after scattering from the structure. Nevertheless, increasing electron energy to 2MeV can reduce blurring and produce an acceptable image quality for thick specimens in the TEM. Copyright © 2016 Elsevier Ltd. All rights reserved.
Kenton, Kimberly
2017-09-01
This month we focus on current research in asymptomatic microscopic hematuria. Dr. Kenton discusses four recent publications, which are concluded with a "bottom line" that is a take-home message. A complete reference for each can be found on on this page along with direct links to abstracts.
[Description and histology identification of several algae of Sargassum sp].
Dong, Yan; Li, Yushan; Cui, Zheng; Zhang, Zhicheng; Liu, Dongchun; Wang, Chunyang
2002-04-01
This paper reported the description characters and microscopical identification of seven kinds of algae of Sargassum sp., Sargassum pallidum (Tum.) C. Ag., S. fusiforme (Harv.) Setch., S. horneri (Tum.) C. Ag., S. hemiphyllum (Turh.) C. Ag., S. thunbergii (Mert.) O'Kuntze, S. polycystum C. Ag. and S. kjellmanianum Yendo. The results revealed that there were clear differences in the description characters and microscopical identification of the seven kinds of algae of Sargassum sp. These studies provided a scientific basis for distinguishing crude drug of algae, developing and making use of alga natural resources of Sargassum sp.
Second-harmonic generation microscopy of tooth
NASA Astrophysics Data System (ADS)
Kao, Fu-Jen; Wang, Yung-Shun; Huang, Mao-Kuo; Huang, Sheng-Lung; Cheng, Ping C.
2000-07-01
In this study, we have developed a high performance microscopic system to perform second-harmonic (SH)imaging on a tooth. The high sensitivity of the system allows an acquisition rate of 300 seconds/frame with a resolution at 512x512 pixels. The surface SH signal generated from the tooth is also carefully verified through micro-spectroscopy, polarization rotation, and wavelength tuning. In this way, we can ensure the authenticity of the signal. The enamel that encapsulates the dentine is known to possess highly ordered structures. The anisotrophy of the structure is revealed in the microscopic SH images of the tooth sample.
Examining the contents of isolated Xenopus germinal vesicles.
Gall, Joseph G; Wu, Zheng'an
2010-05-01
One can manually isolate the giant oocyte nucleus or germinal vesicle (GV) of Xenopus from a living oocyte with nothing more complicated than jewelers' forceps and a dissecting microscope. Similarly, one can remove the nuclear envelope by hand and allow the lampbrush chromosomes and other nuclear organelles to spread on a microscope slide. After centrifugation, the nuclear contents adhere tightly to the slide, where they can be subjected to immunostaining or fluorescent in situ hybridization for visualization by conventional or confocal microscopy. Preparations of isolated GV contents reveal details of nuclear structure that are almost impossible to attain by more conventional techniques.
Matsubara, Hiroki; Kikugawa, Gota; Ishikiriyama, Mamoru; Yamashita, Seiji; Ohara, Taku
2017-09-21
Thermal conductivity of a material can be comprehended as being composed of microscopic building blocks relevant to the energy transfer due to a specific microscopic process or structure. The building block is called the partial thermal conductivity (PTC). The concept of PTC is essential to evaluate the contributions of various molecular mechanisms to heat conduction and has been providing detailed knowledge of the contribution. The PTC can be evaluated by equilibrium molecular dynamics (EMD) and non-equilibrium molecular dynamics (NEMD) in different manners: the EMD evaluation utilizes the autocorrelation of spontaneous heat fluxes in an equilibrium state whereas the NEMD one is based on stationary heat fluxes in a non-equilibrium state. However, it has not been fully discussed whether the two methods give the same PTC or not. In the present study, we formulate a Green-Kubo relation, which is necessary for EMD to calculate the PTCs equivalent to those by NEMD. Unlike the existing theories, our formulation is based on the local equilibrium hypothesis to describe a clear connection between EMD and NEMD simulations. The equivalence of the two derivations of PTCs is confirmed by the numerical results for liquid methane and butane. The present establishment of the EMD-NEMD correspondence makes the MD analysis of PTCs a robust way to clarify the microscopic origins of thermal conductivity.
Gao, Yi-ning; Wang, Dan-ying; Pan, Zong-fu; Mei, Yu-qin; Wang, Zhi-qiang; Zhu, Dan-yan; Lou, Yi-jia
2012-07-01
To set up a platform for phenotype-based primary screening of drug candidates promoting neuronal subtype differentiation in embryonic stem cells (ES) with light microscope. Hanging drop culture 4-/4+ method was employed to harvest the cells around embryoid body (EB) at differentiation endpoint. Morphological evaluation for neuron-like cells was performed with light microscope. Axons for more than three times of the length of the cell body were considered as neuron-like cells. The compound(s) that promote neuron-like cells was further evaluated. Icariin (ICA, 10(-6)mol/L) and Isobavachin (IBA, 10(-7)mol/L) were selected to screen the differentiation-promoting activity on ES cells. Immunofluorescence staining with specific antibodies (ChAT, GABA) was used to evaluate the neuron subtypes. The cells treated with IBA showed neuron-like phenotype, but the cells treated with ICA did not exhibit the morphological changes. ES cells treated with IBA was further confirmed to be cholinergic and GABAergic neurons. Phenotypic screening with light microscope for molecules promoting neuronal differentiation is an effective method with advantages of less labor and material consuming and time saving, and false-positive results derived from immunofluorescence can be avoided. The method confirms that IBA is able to facilitate ES cells differentiating into neuronal cells, including cholinergic neurons and GABAergic neurons.
Oral lactoferrin protects against experimental candidiasis in mice
Velliyagounder, Kabilan; Alsaedi, Wijdan; Alabdulmohsen, Waad; Markowitz, Kenneth; Fine, Daniel H.
2015-01-01
Aims To determine the role of lactoferrin in protecting the oral cavities of mice against Candida albicans infection in lactoferrin knockout (LFKO−/−) mice were compared to wild-type (WT) mice. We also determine the protective role of human lactoferrin in the LFKO−/− mice. Methods and Results Antibiotic treated immunosuppressed mice were inoculated with C. albicans (or sham infection) by oral swab and evaluated for the severity of infection after 7 days of infection. To determine the protective role of hLF, we added 0.3% solution of hLF to the drinking water given to some of the mice. CFU count, scoring of lesions and microscopic observations were carried out to determine the severity of infection. LFKO−/−I mice showed a 2 log (P=0.001) higher CFUs of C. albicans in the oral cavity compared to the WTI mice. LFKO−/−I mice given hLF had a 3 log (P=0.001) reduction in CFUs in the oral cavity compared to untreated LFKO−/−I mice. The severity of infection, observed by light microscopy revealed that the tongue of the LFKO−/−I mice showed more white patches compared to WTI and LFKO−/−I+hLF mice. Scanning electron microscopic observation revealed that more filiform papillae were destroyed in LFKO−/−I mice when compared to WTI or LFKO−/−I +hLF mice. Conclusions Human lactoferrin is important in protecting mice from oral C. albicans infection. Administered hLF may be used to prevent C. albicans infection. Significance and Impact of the Study Human lactoferrin, a multifunctional iron-binding glycoprotein can be used as a therapeutic active ingredient in oral health care products against C. albicans. PMID:25319508
Oral lactoferrin protects against experimental candidiasis in mice.
Velliyagounder, K; Alsaedi, W; Alabdulmohsen, W; Markowitz, K; Fine, D H
2015-01-01
To determine the role of human lactoferrin (hLF) in protecting the oral cavities of mice against Candida albicans infection in lactoferrin knockout (LFKO(-/-)) mice was compared to wild-type (WT) mice. We also aim to determine the protective role of hLF in LFKO(-/-) mice. Antibiotic-treated immunosuppressed mice were inoculated with C. albicans (or sham infection) by oral swab and evaluated for the severity of infection after 7 days of infection. To determine the protective role of hLF, we added 0·3% solution of hLF to the drinking water given to some of the mice. CFU count, scoring of lesions and microscopic observations were carried out to determine the severity of infection. LFKO(-/-) I mice showed a 2 log (P = 0·001) higher CFUs of C. albicans in the oral cavity compared to the WT mice infected with C. albicans (WTI). LFKO(-/-) I mice given hLF had a 3 log (P = 0·001) reduction in CFUs in the oral cavity compared to untreated LFKO(-/-) I mice. The severity of infection, observed by light microscopy, revealed that the tongue of the LFKO(-/-) I mice showed more white patches compared to WTI and LFKO(-/-) I + hLF mice. Scanning electron microscopic observations revealed that more filiform papillae were destroyed in LFKO(-/-) I mice when compared to WTI or LFKO(-/-) I + hLF mice. Human LF is important in protecting mice from oral C. albicans infection. Administered hLF may be used to prevent C. albicans infection. Human LF, a multifunctional iron-binding glycoprotein can be used as a therapeutic active ingredient in oral healthcare products against C. albicans. © 2014 The Society for Applied Microbiology.
No difference in mitochondrial distribution is observed in human oocytes after cryopreservation.
Stimpfel, Martin; Vrtacnik-Bokal, Eda; Virant-Klun, Irma
2017-08-01
The primary aim of this study was to determine if any difference in mitochondrial distribution can be observed between fresh and cryopreserved (slow-frozen/thawed and vitrified/warmed) oocytes when oocytes are stained with Mitotracker Red CMXRos and observed under a conventional fluorescent microscope. Additionally, the influence of cryopreservation procedure on the viable rates of oocytes at different maturation stages was evaluated. The germinal vesicle (GV) and MII oocytes were cryopreserved with slow-freezing and vitrification. After thawing/warming, oocytes were stained using Mitotracker Red CMXRos and observed under a conventional fluorescent microscope. Mitotracker staining revealed that in GV oocytes the pattern of mitochondrial distribution appeared as aggregated clusters around the whole oocyte. In mature MII oocytes, three different patterns of mitochondrial distribution were observed; a smooth pattern around the polar body with aggregated clusters at the opposite side of the polar body, a smooth pattern throughout the whole cell, and aggregated clusters as can be seen in GV oocytes. There were no significant differences in the observed patterns between fresh, vitrified/warmed and frozen/thawed oocytes. When comparing the viable rates of oocytes after two different cryopreservation procedures, the results showed no significant differences, although the trend of viable MII oocytes tends to be higher after vitrification/warming and for viable GV oocytes it tends to be higher after slow-freezing/thawing. Mitotracker Red CMXRos staining of mitochondria in oocytes did not reveal differences in mitochondrial distribution between fresh and cryopreserved oocytes at different maturity stages. Additionally, no difference was observed in the viable rates of GV and MII oocytes after slow-freezing/thawing and vitrification/warming.
Krämer, Norbert; Reinelt, Christian; Richter, Gert; Petschelt, Anselm; Frankenberger, Roland
2009-06-01
This controlled prospective split-mouth study evaluated the clinical behavior of two different resin composites in extended Class II cavities over a period of four years. Thirty patients received 68 direct resin composite restorations (Grandio bonded with Solobond M: n=36, Tetric Ceram bonded with Syntac: n=32) by one dentist in a private practice. All restorations were replacement fillings, 24 cavities (35%) revealed no enamel at the bottom of the proximal box, in 33 cavities (48%) the proximal enamel width was less than 0.5mm. The restorations were examined according to modified USPHS criteria at baseline, and after six months, one, two, and four years. At each recall, impressions were taken for replica preparation. Replicas of 44 select subjects were assessed for marginal quality under a stereo light microscope (SLM) at 130x and 22 replicas were assessed under a scanning electron microscope (SEM) at 200x. Both recall rate and survival rate were 100% after four years of clinical service. No significant difference was found between the restorative materials (p>0.05; Mann-Whitney U-test). Hypersensitivities were significantly reduced over time (p<0.05; Friedman test). A significant deterioration over time was found for the criteria marginal integrity (66% bravo after four years), tooth integrity (15% bravo), filling integrity (73% bravo) and proximal contact (p<0.05; Friedman test). SLM and SEM analysis of restoration margins revealed differences in the amount of perfect margins, in favor of Tetric Ceram (p<0.05). Both materials performed satisfactorily over the four-year observation period. Due to the extension of the restorations, wear was clearly visible after four years of clinical service with 50% bravo ratings.
Yurt, Kıymet Kübra; Kivrak, Elfide Gizem; Altun, Gamze; Mohamed, Hamza; Ali, Fathelrahman; Gasmalla, Hosam Eldeen; Kaplan, Suleyman
2018-02-26
A quantitative description of a three-dimensional (3D) object based on two-dimensional images can be made using stereological methods These methods involve unbiased approaches and provide reliable results with quantitative data. The quantitative morphology of the nervous system has been thoroughly researched in this context. In particular, various novel methods such as design-based stereological approaches have been applied in neuoromorphological studies. The main foundations of these methods are systematic random sampling and a 3D approach to structures such as tissues and organs. One key point in these methods is that selected samples should represent the entire structure. Quantification of neurons, i.e. particles, is important for revealing degrees of neurodegeneration and regeneration in an organ or system. One of the most crucial morphometric parameters in biological studies is thus the "number". The disector counting method introduced by Sterio in 1984 is an efficient and reliable solution for particle number estimation. In order to obtain precise results by means of stereological analysis, counting items should be seen clearly in the tissue. If an item in the tissue cannot be seen, these cannot be analyzed even using unbiased stereological techniques. Staining and sectioning processes therefore play a critical role in stereological analysis. The purpose of this review is to evaluate current neuroscientific studies using optical and physical disector counting methods and to discuss their definitions and methodological characteristics. Although the efficiency of the optical disector method in light microscopic studies has been revealed in recent years, the physical disector method is more easily performed in electron microscopic studies. Also, we offered to readers summaries of some common basic staining and sectioning methods, which can be used for stereological techniques in this review. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kheiralla, Zeinab Mohamed Hassan; Rushdy, Abeer Ahmed; Betiha, Mohamed Ahmed; Yakob, Naglaa Abdullah Nasif
2014-08-01
Syntheses of silver nanocomposites (AgNPs@MMT) were fabricated with different silver nanoparticles to montmorillonite clay (MMT) ratios using microwave-assisted synthesis method, and silver nitrate was used as the precursor of silver nanoparticles. The antibacterial activities of the nanocomposite were evaluated against Staphylococcus aureus and Pseudomonas aeruginosa bacteria by the disk diffusion and macrodilution broth techniques. The prepared nanocomposites were characterized by N2 adsorption-desorption isotherms, X-ray diffraction (XRD), field emission scanning electron microscope, high-resolution transmission electron microscope (HRTEM), X-ray fluorescence spectroscopy and Fourier transform infrared spectroscopy. The wide-angle XRD patterns and HRTEM images demonstrate that silver nanoparticles were fabricated on surface and within MMT channels. The diameters of the AgNPs were below 15 nm, as indicated by UV-Vis absorption, which effectively controlled by the pores of the MMT host. Data revealed that 5 % AgNP@MMT nanocomposite is much more effective than silver nitrate and shows strong antibacterial activities. The efficiency of antibiotics increased when combined with 5 % AgNP@MMT nanocomposite against both the tested strains. The increase in fold area was higher in case of P. aeruginosa than S. aureus. The highest percentage of fold increases was found for Sulfamethaxole/Trimethoprim and Oxacillin followed by Levofloxaci and Nalidixic acid against P.aeruginosa. On the other hand, Imipenem increases activity in presence of AgNP@MMT nanocomposite against S. aureus. Overall, the synergistic effect of antibiotics and nanoparticles clearly revealed that nanoparticles can be effectively used in combination with antibiotics in order to improve their efficiency against various pathogenic microbes. The suspensions of the synthesized nanocomposites were found to be stable over a long time without any sign of detachment of AgNPs.
Provo-Klimek, Judy A; Troyer, Deryl L
2002-01-01
The authors have previously reported the development of a novel technique for sampling and preparing tissue slides for routine microscopic examination, without the use of a microtome. Termed "RAMP" (Rapid Adhesive Mediated Procedure), this simple, albeit somewhat crude, technique holds promise as a method that can be used in the field by veterinary practitioners for rapid microscopic evaluations to obtain early preliminary estimates of the nature of a mass or lesion. We incorporated the use of this method into a gross anatomy course in an attempt to gauge its utility for novices in tissue sampling and histology slide preparation. By having each group of students take a tissue sample from their cadaver, the activity simulated an actual necropsy situation in which practitioners in the field might use the technique. Because students were able to follow their specimen from sampling to microscopic examination, the activity provided a valuable integration of their learning of gross and microscopic anatomy. We conducted an evaluation of the process and the resulting slides with two successive classes of students. We conclude that the RAMP method is reasonably successful in the hands of individuals not trained in tissue preparation; was well received by the students as a valuable learning tool; and could potentially yield useful histological information for practicing veterinarians. Limitations of the method are also discussed.
Pseudogynecomastia due to neurofibromatosis--a light microscopic and ultrastructural study.
Lipper, S; Willson, C F; Copeland, K C
1981-08-01
A six year old boy with bilateral breast enlargement was found to have a normal endocrine status. Resected tissue revealed the features of pseudogynecomastia due to a proliferation of fibrous tissue traversed by neuroid structures. Multinucleated giant cells were present within the fibrous tissue. Ultrastructural study revealed organized nerve elements in a collagenous stroma. The multinucleated giant cells appeared to be variants of the predominant stromal fibroblasts.
Chen, Ye; Liu, Jonathan T C
2013-06-01
Dual-axis confocal (DAC) microscopy has been found to exhibit superior rejection of out-of-focus and multiply scattered background light compared to conventional single-axis confocal microscopy. DAC microscopes rely on the use of separated illumination and collection beam paths that focus and intersect at a single focal volume (voxel) within tissue. While it is generally recognized that the resolution and contrast of a DAC microscope depends on both the crossing angle of the DAC beams, 2θ, and the focusing numerical aperture of the individual beams, α, a detailed study to investigate these dependencies has not been performed. Contrast and resolution are considered as two main criteria to assess the performance of a point-scanned DAC microscope (DAC-PS) and a line-scanned DAC microscope (DAC-LS) as a function of θ and α. The contrast and resolution of these designs are evaluated by Monte-Carlo scattering simulations and diffraction theory calculations, respectively. These results can be used for guiding the optimal designs of DAC-PS and DAC-LS microscopes.
Neděla, Vilém; Hřib, Jiří; Havel, Ladislav; Hudec, Jiří; Runštuk, Jiří
2016-05-01
This article describes the surface structure of Norway spruce early somatic embryos (ESEs) as a typical culture with asynchronous development. The microstructure of extracellular matrix covering ESEs were observed using the environmental scanning electron microscope as a primary tool and using the scanning electron microscope with cryo attachment and laser electron microscope as a complementary tool allowing our results to be proven independently. The fresh samples were observed in conditions of the air environment of the environmental scanning electron microscope (ESEM) with the pressure from 550Pa to 690Pa and the low temperature of the sample from -18°C to -22°C. The samples were studied using two different types of detector to allow studying either the thin surface structure or material composition. The scanning electron microscope with cryo attachment was used for imaging frozen extracellular matrix microstructure with higher resolution. The combination of both electron microscopy methods was suitable for observation of "native" plant samples, allowing correct evaluation of our results, free of error and artifacts. Copyright © 2016 Elsevier Ltd. All rights reserved.
Corrosion resistance evaluation of Pd-free Ag-Au-Pt-Cu dental alloys.
Fujita, Takeshi; Shiraishi, Takanobu; Takuma, Yasuko; Hisatsune, Kunihiro
2011-01-01
The corrosion resistance of nine experimental Pd-free Ag-Au-Pt-Cu dental alloys in a 0.9% NaCl solution was investigated using cyclic voltammetry (CV), optical microscopy, and scanning electron microscopy (SEM). CV measurements revealed that the breakdown potential (E(bd)) and zero current potential (E(zc)) increased with increasing Au/(Au+Ag) atomic ratio. Thus, the Au/(Au+Ag) atomic ratio, but not the Cu content, influenced the corrosion resistance of Ag-Au-Pt-Cu alloys. After the forward scan of CV, both optical and scanning electron microscope images showed that in all the experimental alloys, the matrix phase was corroded but not the second phase. From corrosion resistance viewpoint, the Ag-Au-Pt-Cu alloys seemed to be suitable for clinical application.
Retinoblastoma in the adolescent. Unusual clinical and histopathology findings.
Hernández-Ayuso, I; Ríos y Valles-Valles, D; Lome-Maldonado, C; Gómez-Leal, A; Rodríguez-Martínez, H A; Rodríguez-Reyes, A A
2016-03-01
A 17-year- old male with 2years history of an intraocular mass and progressive visual loss of the left eye. Spontaneous sclera rupture occurred during enucleation. Microscopic evaluation with H-E, PAS and immunohistochemistry (NSE, GAFP, SYN, CD99) revealed a small blue round cell malignant neoplasm with extensive necrosis and apoptosis. The optic nerve, ciliary body, choroid, anterior chamber, and sclera were infiltrated. SYN was positive and CD99 was negative in neoplastic cells, consistent with a poorly differentiated retinoblastoma. Retinoblastoma is the most frequent primary intraocular malignant tumour in childhood, but occasionally older patients can be affected. Immunohistochemistry is mandatory in poorly differentiated retinoblastomas. Copyright © 2015 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.
Disseminated sinus histiocytosis with massive lymphadenopathy: its pathologic aspects.
Buchino, J J; Byrd, R P; Kmetz, D R
1982-01-01
Sinus histiocytosis with massive lymphadenopathy (SHML) is generally regarded as a benign, self-limited, pseudolymphomatous process requiring little or no therapy. We studied a 13-year-old black boy with a ten-year clinical course of SHML that had varying, intermittent sites of extranodal involvement, including bone, submandibular gland, trachea, eye, and spinal cord. At the time of death, which was attributed to SHML, additional extranodal sites of involvement included thymus, kidney, heart, liver, and base of brain. Microscopic examination of the SHML lesions at the time of autopsy revealed varying stages of development, from proliferation to involution. This case illustrates that SHML may involve multiple organ systems, can kill, and that histologic evaluation of disease activity at one site cannot be used as an indicator of activity at another.
Adsorption and inhibitive properties of sildenafil (Viagra) for zinc in hydrochloric acid solution
NASA Astrophysics Data System (ADS)
Fouda, A. S.; Ibrahim, H.; Atef, M.
Sildenafil (Viagra) was investigated as corrosion inhibitor for Zn in 1 M HCl solution using chemical and electrochemical methods at 25 °C. Electrochemical results showed that this drug is efficient inhibitor for Zn in HCl and the inhibition efficiency (IE) reached to 91% at 300 ppm. The IE increases with the drug concentration and decreases with increasing temperature. The adsorption of this drug on Zn surface follows Langmuir adsorption isotherm. The polarization plots revealed that Sildenafil acts as a mixed-type inhibitor. The thermodynamic parameters of activation and adsorption were calculated and discussed. The surface morphology of the Zn specimens was evaluated using scanning electron microscope (SEM), energy dispersive X-ray (EDX), atomic force microscopy (AFM) and Fourier transform infrared spectroscopy (FTIR) techniques.
NASA Astrophysics Data System (ADS)
Ghanbari, Alireza; Attar, Mohammadreza Mohammadzade
2014-10-01
In this study, the anti-corrosion performance of phosphated and zirconium treated mild steel (ZTMS) with and without organic coating was evaluated using AC and DC electrochemical techniques. The topography and morphology of the zirconium treated samples were studied using atomic force microscopy (AFM) and field emission scanning electron microscope (FE-SEM) respectively. The results revealed that the anti-corrosion performance of the phosphate layer was superior to the zirconium conversion layer without an organic coating due to very low thickness and porous nature of the ZTMS. Additionally, the corrosion behavior of the organic coated substrates was substantially different. It was found that the corrosion protection performance of the phosphate steel and ZTMS with an organic coating is in the same order.
Robot-assisted vasovasostomy using a single layer anastomosis.
Marshall, Michael T; Doudt, Alexander D; Berger, Jonathan H; Auge, Brian K; Christman, Matthew S; Choe, Chong H
2017-09-01
Of all patients who have vasectomies performed in the United States, upwards of 6% will pursue a vasectomy reversal. Currently, the gold-standard reversal procedure is a microscopic vasovasostomy utilizing either a one or two-layer vasal anastomosis. Unfortunately, most urologists do not perform these procedures as they require extensive training and experience in microsurgery. The objective of our study was to evaluate the feasibility and success rate of robot-assisted vasovasostomy performed at our institution. We completed a retrospective review of our experience with vasectomy reversal utilizing the da Vinci ® Surgical System and a single layer vasal anastomosis. A successful reversal was defined as a return of sperm on semen analysis or light microscopy. Since 2009 we have completed 79 robotic vasectomy reversals, 60 of which utilized a single-layer vasal anastomosis. The average obstructive interval was 5.7 ± 2.2 years. Average operative time was 192 min. 42 patients returned for a post-operative semen evaluation at an average time of 4.3 months post-procedure revealing a success rate of 88% (37 out of 42). Post-operative semen parameters were significant for an average sperm density of 31.0 million/mL with an average motility of 29.1%. Robot-assisted vasovasostomy with a single layer anastomosis has overall success rates that are similar to that of reported microscopic vasovasostomy rates. Although more study is warranted with regard to cost, we feel as though our study demonstrates an alternative approach to vasectomy reversal that can be performed successfully by urologists trained in robotic surgery.
Comparison of candidate materials for a synthetic osteo-odonto keratoprosthesis device.
Tan, Xiao Wei; Perera, A Promoda P; Tan, Anna; Tan, Donald; Khor, K A; Beuerman, Roger W; Mehta, Jodhbir S
2011-01-05
Osteo-odonto keratoprosthesis is one of the most successful forms of keratoprosthesis surgery for end-stage corneal and ocular surface disease. There is a lack of detailed comparison studies on the biocompatibilities of different materials used in keratoprosthesis. The aim of this investigation was to compare synthetic bioinert materials used for keratoprosthesis surgery with hydroxyapatite (HA) as a reference. Test materials were sintered titanium oxide (TiO(2)), aluminum oxide (Al(2)O(3)), and yttria-stabilized zirconia (YSZ) with density >95%. Bacterial adhesion on the substrates was evaluated using scanning electron microscopy and the spread plate method. Surface properties of the implant discs were scanned using optical microscopy. Human keratocyte attachment and proliferation rates were assessed by cell counting and MTT assay at different time points. Morphologic analysis and immunoblotting were used to evaluate focal adhesion formation, whereas cell adhesion force was measured with a multimode atomic force microscope. The authors found that bacterial adhesion on the TiO(2), Al(2)O(3), and YSZ surfaces were lower than that on HA substrates. TiO(2) significantly promoted keratocyte proliferation and viability compared with HA, Al(2)O(3,) and YSZ. Immunofluorescent imaging analyses, immunoblotting, and atomic force microscope measurement revealed that TiO(2) surfaces enhanced cell spreading and cell adhesion compared with HA and Al(2)O(3). TiO(2) is the most suitable replacement candidate for use as skirt material because it enhanced cell functions and reduced bacterial adhesion. This would, in turn, enhance tissue integration and reduce device failure rates during keratoprosthesis surgery.
Exuberant mucometra associated with atresia of the cervix in a queen.
Batista-Arteaga, M; Santana, M; Espinosa-de-los-Monteros, A; Déniz, S; Alamo, D; Herráez, P
2012-10-01
This short communication reports the clinical, ultrasonographic and histopathological findings in a cat with atresia of the uterine cervix and mucometra. After 6 months of continuous oestrous behaviour, a remarkable abdominal enlargement was observed in a 14-year-old queen. A presumptive diagnosis of mucometra was concluded after the ultrasound evaluation and based on clinical signs and blood analyses. Ovariohysterectomy revealed a notable symmetrical distension (4-5 cm in diameter) of both uterine horns that were filled with fluid (690 ml); microbiological analyses confirmed the aseptic nature of the uterine fluid. Ovarian follicular cysts and cystic subsurface epithelial structures, >1.5 cm in diameter, were present in both ovaries and no corpora lutea were observed. Gross and microscopic evaluation of the uterus confirmed the development of cystic endometrial hyperplasia and the absence of an internal cervical os. The endometrial hyperplasia and mucometra could have developed as a consequence of repeated oestrogenic stimulation. © 2011 Blackwell Verlag GmbH.
Failure Analysis and Magnetic Evaluation of Tertiary Superheater Tube Used in Gas-Fired Boiler
NASA Astrophysics Data System (ADS)
Mohapatra, J. N.; Patil, Sujay; Sah, Rameshwar; Krishna, P. C.; Eswarappa, B.
2018-02-01
Failure analysis was carried out on a prematurely failed tertiary superheater tube used in gas-fired boiler. The analysis includes a comparative study of visual examination, chemical composition, hardness and microstructure at failed region, adjacent and far to failure as well as on fresh tube. The chemistry was found matching to the standard specification, whereas the hardness was low in failed tube compared to the fish mouth opening region and the fresh tube. Microscopic examination of failed sample revealed the presence of spheroidal carbides of Cr and Mo predominantly along the grain boundaries. The primary cause of failure is found to be localized heating. Magnetic hysteresis loop (MHL) measurements were carried out to correlate the magnetic parameters with microstructure and mechanical properties to establish a possible non-destructive evaluation (NDE) for health monitoring of the tubes. The coercivity of the MHL showed a very good correlation with microstructure and mechanical properties deterioration enabling a possible NDE technique for the health monitoring of the tubes.
Riyaz, N; Sasidharanpillai, S; Rahima, S; Bindu, V; Shaan, M; Raghavan, N T; Mohan, L; Janardhanan, A K
2015-08-01
Pyoderma gangrenosum (PG) is a neutrophilic dermatosis of unknown aetiology. We report a 27-year-old male patient with diabetes, who presented with a nonhealing ulcer on the left leg, pruritic hyperpigmented papules distributed over the trunk and limbs, and chronic diarrhoea. He had eosinophilia, low haemoglobin and serum IgE levels, and raised erythrocyte sedimentation rate. Histopathology of the leg ulcer was consistent with the diagnosis of PG, while the histology of the hyperpigmented papule revealed tissue eosinophilia. Subsequent evaluation was conclusive of the diagnosis of PG, idiopathic hypereosinophilic syndrome (IHES) and selective IgE deficiency. Dexamethasone pulse therapy achieved resolution of the ulcer and reduction in the eosinophilia. Further evaluation for the persistent diarrhoea led to a diagnosis of lymphocytic colitis (LC), which responded to budesonide. To our knowledge, the association of PG with IHES, selective IgE deficiency or LC has not been previously reported. © 2015 British Association of Dermatologists.
Bellefeuille, M; Peters, D F; Nolin, M; Slusarewicz, P; Telgenhoff, D
2017-05-01
Collagen cross-linking is an attractive therapeutic route aimed at supplementing natural collagen stabilisation. In this study the toxicity of the cross-linker genipin (GP) was examined in avascular (tendon) and vascular (dermis) tissue. High doses of GP were injected intratendinously into three yearling horses and evaluated at various time points up to 30 days. A second group of three yearlings were injected into the dermis and evaluated at various time points up to 1 year. Metrics used included lameness, circumferential swelling, ultrasound evaluation, microscopic morphology, collagen production and systemic effect on blood parameters. The tendon injection sites exhibited mild lameness and swelling with no apparent systemic toxicity or stabilisation defects. Treated tendons exhibited increased linear collagen microscopically. Dermal injections showed similar results, with mild swelling at the injection site. Microscopic morphology resulted in a decrease in dermal collagen at 30 days post-injection. Dermis injected at the high dose of 355 mmol/L examined 1 year post-treatment appeared similar to the untreated biopsies; however, there was an increase in mature collagen. GP injection appeared to be well tolerated, with transient lameness and mild circumferential swelling when injected into the tendon and local tissue swelling when injected into the dermis. No systemic hypersensitivities or toxicities were observed. Microscopically, GP resulted in increased linear collagen in tendons at 30 days post-injection and overall increased collagen in dermal tissue when evaluated 1 year post-injection. © 2017 Australian Veterinary Association.
Kaufmann, Ronnie; Blum, Shlomo E; Elad, Daniel; Zur, Gila
2016-08-01
Point-of-care Dermatophyte Test Medium (PoC-DTM) is a diagnostic procedure to rule in/rule out dermatophytosis in veterinary clinics. To evaluate the performance of PoC-DTM in the clinic compared to DTM plate culture in a mycology laboratory and to compare results obtained by general practitioners and referral clinicians. Hair samples were collected from 47 cats and 54 dogs with suspected dermatophytosis and from nine healthy controls (seven cats and two dogs). This was a multicentre blinded study. In one group (65 suspected cases, 9 healthy controls), PoC-DTM results were evaluated by clinicians in a referral clinic (SP group) who examined the colony morphology macroscopically and microscopically. In the other group (36 suspected cases) PoC-DTM results were evaluated by clinicians from general practice for colour change only, with no macroscopic or microscopic examination (GP group). All hair samples were also cultured on DTM plates in a mycology laboratory. Laboratory culture was considered the gold standard for comparison. Agreements between tests were 97% (two false positive; κ = 0.839) and 80.6% (five false positives and two false negatives; κ = 0.466) in the SP and GP groups, respectively. This difference between groups was significant (P = 0.024). When applying macroscopic and microscopic evaluation of the colony, PoC-DTM is accurate for diagnosing dermatophytes with only a 3% chance of error. However, when macroscopic and microscopic examination is not included there is significant (19.4%) chance for an incorrect diagnosis. © 2016 ESVD and ACVD.
Fractal evaluation of drug amorphicity from optical and scanning electron microscope images
NASA Astrophysics Data System (ADS)
Gavriloaia, Bogdan-Mihai G.; Vizireanu, Radu C.; Neamtu, Catalin I.; Gavriloaia, Gheorghe V.
2013-09-01
Amorphous materials are metastable, more reactive than the crystalline ones, and have to be evaluated before pharmaceutical compound formulation. Amorphicity is interpreted as a spatial chaos, and patterns of molecular aggregates of dexamethasone, D, were investigated in this paper by using fractal dimension, FD. Images having three magnifications of D were taken from an optical microscope, OM, and with eight magnifications, from a scanning electron microscope, SEM, were analyzed. The average FD for pattern irregularities of OM images was 1.538, and about 1.692 for SEM images. The FDs of the two kinds of images are less sensitive of threshold level. 3D images were shown to illustrate dependence of FD of threshold and magnification level. As a result, optical image of single scale is enough to characterize the drug amorphicity. As a result, the OM image at a single scale is enough to characterize the amorphicity of D.
Mangar, Preeti; Saha, Aniruddha
2018-01-01
The aim of the present study is to evaluate plant growth promoting and biocontrol efficacy of a Serratia marcescens strain ETR17 isolated from tea rhizosphere for the effective management of root rot disease in tea. Isolated bacterial culture ETR17 showed significant level of in vitro antagonism against nine different foliar and root pathogens of tea. The phenotypic and molecular characterization of ETR17 revealed the identity of the bacterium as Serratia marcescens. The bacterium was found to produce several hydrolytic enzymes like chitinase, protease, lipase, cellulase and plant growth promoting metabolites like IAA and siderophore. Scanning electron microscopic studies on the interaction zone between pathogen and antagonistic bacterial isolate revealed severe deformities in the fungal mycelia. Spectral analyses (LC-ESI-MS, UV-VIS spectrophotometry and HPLC) and TLC indicated the presence of the antibiotics pyrrolnitrin and prodigiosin in the extracellular bacterial culture extracts. Biofilm formation by ETR17 on polystyrene surface was also observed. In vivo application of talc-based formulations prepared with the isolate ETR17 in tea plantlets under green house conditions revealed effective reduction of root-rot disease as well as plant growth promotion to a considerable extent. Viability studies with the ETR17 talc formulation showed the survivability of the isolate up to six months at room temperature. The sustenance of ETR17 (concentration of 8-9x108 cfu g-1) in the soil after the application of talc formulation was recorded by ELISA. Safety studies revealed that ETR17 did not produce hemolysin as observed in pathogenic Serratia strains. The biocontrol strain reported in this study can be used for field application in order to minimize the use of chemical fungicides for disease control in tea gardens. PMID:29466418
Dhar Purkayastha, Gargee; Mangar, Preeti; Saha, Aniruddha; Saha, Dipanwita
2018-01-01
The aim of the present study is to evaluate plant growth promoting and biocontrol efficacy of a Serratia marcescens strain ETR17 isolated from tea rhizosphere for the effective management of root rot disease in tea. Isolated bacterial culture ETR17 showed significant level of in vitro antagonism against nine different foliar and root pathogens of tea. The phenotypic and molecular characterization of ETR17 revealed the identity of the bacterium as Serratia marcescens. The bacterium was found to produce several hydrolytic enzymes like chitinase, protease, lipase, cellulase and plant growth promoting metabolites like IAA and siderophore. Scanning electron microscopic studies on the interaction zone between pathogen and antagonistic bacterial isolate revealed severe deformities in the fungal mycelia. Spectral analyses (LC-ESI-MS, UV-VIS spectrophotometry and HPLC) and TLC indicated the presence of the antibiotics pyrrolnitrin and prodigiosin in the extracellular bacterial culture extracts. Biofilm formation by ETR17 on polystyrene surface was also observed. In vivo application of talc-based formulations prepared with the isolate ETR17 in tea plantlets under green house conditions revealed effective reduction of root-rot disease as well as plant growth promotion to a considerable extent. Viability studies with the ETR17 talc formulation showed the survivability of the isolate up to six months at room temperature. The sustenance of ETR17 (concentration of 8-9x108 cfu g-1) in the soil after the application of talc formulation was recorded by ELISA. Safety studies revealed that ETR17 did not produce hemolysin as observed in pathogenic Serratia strains. The biocontrol strain reported in this study can be used for field application in order to minimize the use of chemical fungicides for disease control in tea gardens.
Chhabra, Priyanka; Tyagi, Priyanka; Bhatnagar, Aseem; Mittal, Gaurav; Kumar, Amit
2016-01-01
Objective: To develop a chitosan-based scaffold and carry out a complete comprehensive study encompassing optimization of exact chitosan strength, product characterization, toxicity evaluation, in vitro validation in cell culture experiments, and finally in vivo efficacy in animal excision wound model. Materials and Methods: Developed chitosan scaffolds (CSs) were optimized for tissue engineering and wound healing efficacy by means of microstructure, toxicity, and biocompatibility evaluation. Results: Scanning electron microscope (SEM) studies revealed that porosity of CS decreased with increase in chitosan concentration. Chemical stability and integrity of scaffolds were confirmed by Fourier transform infrared studies. Highest swelling percentage (SP) of 500% was observed in 2%, while lowest (200%) was observed in 1% CS. Reabsorption and noncytotoxic property of optimized scaffold were established by enzymatic degradation and MTT assay. Enzymatic degradation suggested 20–45% of weight loss (WL) within 14 days of incubation. Cytotoxicity analysis showed that scaffolds were noncytotoxic against normal human dermal fibroblast human dermal fibroblast cell lines. Significant cellular adherence over the scaffold surface with normal cellular morphology was confirmed using SEM analysis. In vivo efficacy evaluation was carried out by means of reduction in wound size on Sprague-Dawley rats. Sprague-Dawley rats treated with optimized scaffold showed ~ 100% wound healing in comparison to ~80% healing in betadine-treated animals within 14 days. Histological examination depicted advance re-epithelization with better organization of collagen bundle in wound area treated with 2% CS in comparison to conventional treatment or no treatment. Conclusion: This study, thus, reveals that 2% CSs were found to have a great potential in wound healing. PMID:28216954
Identification of Campylobacter with hyperspectral microscope imaging
USDA-ARS?s Scientific Manuscript database
Campylobacter is the major group of bacteria responsible for foodborne gastroenteritis in humans worldwide. Most of the cases of campylobacteriosis have revealed their poultry origins so that various detection methods have been employed from the farm to processing levels. Especially Campylobacter ...
Scanned gate microscopy of inter-edge channel scattering in the quantum Hall regime
NASA Astrophysics Data System (ADS)
Woodside, Michael T.; Vale, Chris; McEuen, Paul L.; Kadow, C.; Maranowski, K. D.; Gossard, A. C.
2000-03-01
Novel scanned probe techniques have recently been used to study in detail the microscopic properties of 2D electron gases in the quantum Hall regime [1]. We report local measurements of the scattering between edge states in a quantum Hall conductor with non-equilibrium edge state populations. Using an atomic force microscope (AFM) tip as a local gate to perturb the edge states, we find that the scattering is dominated by individual, microscopic scattering sites, which we directly image and characterise. The dependence of the scattering on the AFM tip voltage reveals that it involves tunneling both through quasi-bound impurity states and through disorder-induced weak links between the edge states. [1] S. H. Tessmer et al., Nature 392, 51 (1998); K. L. McCormick et al., Phys. Rev. B 59, 4654 (1999); A. Yacoby et al., Solid State Comm. 111, 1 (1999).
A simple backscattering microscope for fast tracking of biological molecules
Sowa, Yoshiyuki; Steel, Bradley C.; Berry, Richard M.
2010-01-01
Recent developments in techniques for observing single molecules under light microscopes have helped reveal the mechanisms by which molecular machines work. A wide range of markers can be used to detect molecules, from single fluorophores to micron sized markers, depending on the research interest. Here, we present a new and simple objective-type backscattering microscope to track gold nanoparticles with nanometer and microsecond resolution. The total noise of our system in a 55 kHz bandwidth is ∼0.6 nm per axis, sufficient to measure molecular movement. We found our backscattering microscopy to be useful not only for in vitro but also for in vivo experiments because of lower background scattering from cells than in conventional dark-field microscopy. We demonstrate the application of this technique to measuring the motion of a biological rotary molecular motor, the bacterial flagellar motor, in live Escherichia coli cells. PMID:21133475
Polarized Light Microscopy in Reproductive and Developmental Biology
KOIKE-TANI, MAKI; TANI, TOMOMI; MEHTA, SHALIN B.; VERMA, AMITABH; OLDENBOURG, RUDOLF
2016-01-01
SUMMARY The polarized light microscope reveals orientational order in native molecular structures inside living cells, tissues, and whole organisms. It is a powerful tool used to monitor and analyze the early developmental stages of organisms that lend themselves to microscopic observations. In this article, we briefly discuss the components specific to a traditional polarizing microscope and some historically important observations on: chromosome packing in the sperm head, the first zygote division of the sea urchin, and differentiation initiated by the first asymmetric cell division in the sand dollar. We then introduce the LC-PolScope and describe its use for measuring birefringence and polarized fluorescence in living cells and tissues. Applications range from the enucleation of mouse oocytes to analyzing the polarized fluorescence of the water strider acrosome. We end with new results on the birefringence of the developing chick brain, which we analyzed between developmental stages of days 12–20. PMID:23901032
Elastically driven intermittent microscopic dynamics in soft solids
NASA Astrophysics Data System (ADS)
Bouzid, Mehdi; Colombo, Jader; Barbosa, Lucas Vieira; Del Gado, Emanuela
2017-06-01
Soft solids with tunable mechanical response are at the core of new material technologies, but a crucial limit for applications is their progressive aging over time, which dramatically affects their functionalities. The generally accepted paradigm is that such aging is gradual and its origin is in slower than exponential microscopic dynamics, akin to the ones in supercooled liquids or glasses. Nevertheless, time- and space-resolved measurements have provided contrasting evidence: dynamics faster than exponential, intermittency and abrupt structural changes. Here we use 3D computer simulations of a microscopic model to reveal that the timescales governing stress relaxation, respectively, through thermal fluctuations and elastic recovery are key for the aging dynamics. When thermal fluctuations are too weak, stress heterogeneities frozen-in upon solidification can still partially relax through elastically driven fluctuations. Such fluctuations are intermittent, because of strong correlations that persist over the timescale of experiments or simulations, leading to faster than exponential dynamics.
Zhuang, Kaiwen; Ran, Xin; Lei, Song; Zhang, Chaoliang; Lama, Jebina; Ran, Yuping
2014-01-01
Trichophyton violaceum is a pathogen of tinea capitis and usually cause infection of scalp and hair in children. To investigate the parasitic form of T. violaceum in the human hair tissue, the infected hair strands were collected from a 9-year-old boy with tinea capitis due to T. violaceum and observed under both the scanning electron microscope (SEM) and transmission electron microscope (TEM). The SEM and TEM findings revealed that T. violaceum parasitically lives in the hair shaft in various forms and the morphological transformation of the fungus from hyphae into arthrospores was noted. The involved hair shaft was damaged to the great extent and its ultrastructural changes were evident. Those morphological characteristics of T. violaceum and the three-dimensional ultastructure changes of infected hairs give a better knowledge about the host-fungus relationship in tinea capitis. © 2014 Wiley Periodicals, Inc.
Bone structure of the temporo-mandibular joint in the individuals aged 18-25.
Parafiniuk, M; Gutsch-Trepka, A; Trepka, S; Sycz, K; Wolski, S; Parafiniuk, W
1998-01-01
Osteohistometric studies were performed in 15 female and 15 male cadavers aged 18-25. Condyloid process and right and left acetabulum of the temporo-mandibular joint have been studied. Density has been investigated using monitor screen linked with microscope (magnification 80x). Density in the spongy part of the condyloid process was 26.67-26.77%; in the subchondrial layer--72.13-72.72%, and in the acetabular wall 75.03-75.91%. Microscopic structure of the bones of the temporo-mandibular joint revealed no differences when compared with images of compact and cancellous bone shown in the histology textbooks. Sex and the side of the body had no influence on microscopic image and proportional bone density. Isles of chondrocytes in the trabeculae of the spongy structure of the condyloid process were found in 4 cases and isles of the condensed bone resembling the compact pattern in 7 cases.
Evaluation of Encapsulated Inhibitor for Autonomous Corrosion Protection
NASA Technical Reports Server (NTRS)
Johnsey, M. N.; Li, W.; Buhrow, J. W.; Calle, L. M.; Pearman, B. P.; Zhang, X.
2015-01-01
This work concerns the development of smart coating technologies based on microencapsulation for the autonomous control of corrosion. Microencapsulation allows the incorporation of corrosion inhibitors into coating which provides protection through corrosion-controlled release of these inhibitors.One critical aspect of a corrosion protective smart coating is the selection of corrosion inhibitor for encapsulation and comparison of the inhibitor function before and after encapsulation. For this purpose, a systematic approach is being used to evaluate free and encapsulated corrosion inhibitors by salt immersion. Visual, optical microscope, and Scanning Electron Microscope (with low-angle backscatter electron detector) are used to evaluate these inhibitors. It has been found that the combination of different characterization tools provide an effective method for evaluation of early stage localized corrosion and the effectiveness of corrosion inhibitors.
Analysis of three microscopic characters for separating the wood of Pinus contorta and P. ponderosa
Alex C. Wiedenhoeft; Regis B. Miller; Terra J. Theim
2003-01-01
Three microscopic characters were evaluated for the identification of Pinus contorta and Pinus ponderosa. The tangential diameter of the resin canals, including the epithelium, was compared to the tangential diameter of the entire resin canal complex. The latter measurement was shown to give diagnostic results for these species. Data from the examination of ray...
Single-channel stereoscopic ophthalmology microscope based on TRD
NASA Astrophysics Data System (ADS)
Radfar, Edalat; Park, Jihoon; Lee, Sangyeob; Ha, Myungjin; Yu, Sungkon; Jang, Seulki; Jung, Byungjo
2016-03-01
A stereoscopic imaging modality was developed for the application of ophthalmology surgical microscopes. A previous study has already introduced a single-channel stereoscopic video imaging modality based on a transparent rotating deflector (SSVIM-TRD), in which two different view angles, image disparity, are generated by imaging through a transparent rotating deflector (TRD) mounted on a stepping motor and is placed in a lens system. In this case, the image disparity is a function of the refractive index and the rotation angle of TRD. Real-time single-channel stereoscopic ophthalmology microscope (SSOM) based on the TRD is improved by real-time controlling and programming, imaging speed, and illumination method. Image quality assessments were performed to investigate images quality and stability during the TRD operation. Results presented little significant difference in image quality in terms of stability of structural similarity (SSIM). A subjective analysis was performed with 15 blinded observers to evaluate the depth perception improvement and presented significant improvement in the depth perception capability. Along with all evaluation results, preliminary results of rabbit eye imaging presented that the SSOM could be utilized as an ophthalmic operating microscopes to overcome some of the limitations of conventional ones.
The impact of the condenser on cytogenetic image quality in digital microscope system.
Ren, Liqiang; Li, Zheng; Li, Yuhua; Zheng, Bin; Li, Shibo; Chen, Xiaodong; Liu, Hong
2013-01-01
Optimizing operational parameters of the digital microscope system is an important technique to acquire high quality cytogenetic images and facilitate the process of karyotyping so that the efficiency and accuracy of diagnosis can be improved. This study investigated the impact of the condenser on cytogenetic image quality and system working performance using a prototype digital microscope image scanning system. Both theoretical analysis and experimental validations through objectively evaluating a resolution test chart and subjectively observing large numbers of specimen were conducted. The results show that the optimal image quality and large depth of field (DOF) are simultaneously obtained when the numerical aperture of condenser is set as 60%-70% of the corresponding objective. Under this condition, more analyzable chromosomes and diagnostic information are obtained. As a result, the system shows higher working stability and less restriction for the implementation of algorithms such as autofocusing especially when the system is designed to achieve high throughput continuous image scanning. Although the above quantitative results were obtained using a specific prototype system under the experimental conditions reported in this paper, the presented evaluation methodologies can provide valuable guidelines for optimizing operational parameters in cytogenetic imaging using the high throughput continuous scanning microscopes in clinical practice.
Yoshikawa, Shinichi; Murata, Ryo; Shida, Shigenari; Uwai, Koji; Suzuki, Tsuneyoshi; Katsumata, Shunji; Takeshita, Mitsuhiro
2010-01-01
We observed the surface morphological structures of 60 mg tablets of Loxonin, Loxot, and Lobu using scanning electron microscope (SEM) and atomic force microscope (AFM) to evaluate the dissolution rates. We found a significant difference among the initial dissolution rates of the three kinds of loxoprofen sodium tablets. Petal forms of different sizes were commonly observed on the surface of the Loxonin and Loxot tablets in which loxoprofen sodium was confirmed by measuring the energy-dispersible X-ray (EDX) spectrum of NaKalpha using SEM. However, a petal form was not observed on the surface of the Lobu tablet, indicating differences among the drug production processes. Surface area and particle size of the principal ingredient in tablets are important factors for dissolution rate. The mean size of the smallest fine particles constituting each tablet was also determined with AFM. There was a correlation between the initial dissolution rate and the mean size of the smallest particles in each tablet. Visualizing tablet surface morphology using SEM and AFM provides information on the drug production processes and initial dissolution rate, and is associated with the time course of pharmacological activities after tablet administration.
Travis, Erika K; Vargas, F Hernan; Merkel, Jane; Gottdenker, Nicole; Miller, R Eric; Parker, Patricia G
2006-01-01
The flightless cormorant (Phalacrocorax harrisi) is an endemic species of the Galápagos Islands, Ecuador. Health studies of the species have not previously been conducted. In August 2003, baseline samples were collected from flightless cormorant colonies on the islands of Isabela and Fernandina. Seventy-six birds, from nestlings to adults, were evaluated. Genetic sexing of 70 cormorants revealed 37 females and 33 males. Hematology assessment consisted of packed cell volume (n=19), leukograms (n=69), and blood smear evaluation (n=69). Microscopic evaluation of blood smears revealed microfilaria in 33% (23/69) of the cormorants. Plasma chemistries were performed on 46 cormorants. There was no significant difference in chemistry values or complete blood counts between male and female cormorants or between age groups. Based on a serologic survey to assess exposure to avian pathogens, birds (n=69) were seronegative for West Nile virus, avian paramyxovirus type 1 (Newcastle disease virus), avian paramyxovirus types 2 and 3, avian influenza, infectious bursal disease, infectious bronchitis, Marek's disease (herpes), reovirus, avian encephalomyelitis, and avian adenovirus type 2. Antibodies to avian adenovirus type 1 and Chlamydophila psittaci were found in 31% (21/68) and 11% (7/65) of flightless cormorants respectively. Chlamydophila psittaci was detected via polymerase chain reaction in 6% (2/33) of the cormorants. The overall negative serologic findings of this research suggest that the flightless cormorant is an immunologically naïve species, which may have a reduced capacity to cope with the introduction of novel pathogens.
Choice and maintenance of equipment for electron crystallography.
Mills, Deryck J; Vonck, Janet
2013-01-01
The choice of equipment for an electron crystallography laboratory will ultimately be determined by the available budget; nevertheless, the ideal lab will have two electron microscopes: a dedicated 300 kV cryo-EM with a field emission gun and a smaller LaB(6) machine for screening. The high-end machine should be equipped with photographic film or a very large CCD or CMOS camera for 2D crystal data collection; the screening microscope needs a mid-size CCD for rapid evaluation of crystal samples. The microscope room installations should provide adequate space and a special environment that puts no restrictions on the collection of high-resolution data. Equipment for specimen preparation includes a carbon coater, glow discharge unit, light microscope, plunge freezer, and liquid nitrogen containers and storage dewars. When photographic film is to be used, additional requirements are a film desiccator, dark room, optical diffractometer, and a film scanner. Having the electron microscopes and ancillary equipment well maintained and always in optimum condition facilitates the production of high-quality data.
Five years of experience teaching pathology to dental students using the WebMicroscope
2011-01-01
Background We describe development and evaluation of the user-friendly web based virtual microscopy - WebMicroscope for teaching and learning dental students basic and oral pathology. Traditional students microscopes were replaced by computer workstations. Methods The transition of the basic and oral pathology courses from light to virtual microscopy has been completed gradually over a five-year period. A pilot study was conducted in academic year 2005/2006 to estimate the feasibility of integrating virtual microscopy into a traditional light microscopy-based pathology course. The entire training set of glass slides was subsequently converted to virtual slides and placed on the WebMicroscope server. Giving access to fully digitized slides on the web with a browser and a viewer plug-in, the computer has become a perfect companion of the student. Results The study material consists now of over 400 fully digitized slides which covering 15 entities in basic and systemic pathology and 15 entities in oral pathology. Digitized slides are linked with still macro- and microscopic images, organized with clinical information into virtual cases and supplemented with text files, syllabus, PowerPoint presentations and animations on the web, serving additionally as material for individual studies. After their examinations, the students rated the use of the software, quality of the images, the ease of handling the images, and the effective use of virtual slides during the laboratory practicals. Responses were evaluated on a standardized scale. Because of the positive opinions and support from the students, the satisfaction surveys had shown a progressive improvement over the past 5 years. The WebMicroscope as a didactic tool for laboratory practicals was rated over 8 on a 1-10 scale for basic and systemic pathology and 9/10 for oral pathology especially as various students’ suggestions were implemented. Overall, the quality of the images was rated as very good. Conclusions An overwhelming majority of our students regarded a possibility of using virtual slides at their convenience as highly desirable. Our students and faculty consider the use of the virtual microscope for the study of basic as well as oral pathology as a significant improvement over the light microscope. PMID:21489183
Microscope sterility during spine surgery.
Bible, Jesse E; O'Neill, Kevin R; Crosby, Colin G; Schoenecker, Jonathan G; McGirt, Matthew J; Devin, Clinton J
2012-04-01
Prospective study. Assess the contamination rates of sterile microscope drapes after spine surgery. The use of the operating microscope has become more prevalent in certain spine procedures, providing superior magnification, visualization, and illumination of the operative field. However, it may represent an additional source of bacterial contamination and increase the risk of developing a postoperative infection. This study included 25 surgical spine cases performed by a single spine surgeon that required the use of the operative microscope. Sterile culture swabs were used to obtain samples from 7 defined locations on the microscope drape after its use during the operation. The undraped technician's console was sampled in each case as a positive control, and an additional 25 microscope drapes were swabbed immediately after they were applied to the microscope to obtain negative controls. Swab samples were assessed for bacterial growth on 5% sheep blood Columbia agar plates using a semiquantitative technique. No growth was observed on any of the 25 negative control drapes. In contrast, 100% of preoperative and 96% of postoperative positive controls demonstrated obvious contamination. In the postoperative group, all 7 sites of evaluation were found to be contaminated with rates of 12% to 44%. Four of the 7 evaluated locations were found to have significant contamination rates compared with negative controls, including the shafts of the optic eyepieces on the main surgeon side (24%, P = 0.022), "forehead" portion on both the main surgeon (24%, P = 0.022) and assistant sides (28%, P = 0.010), and "overhead" portion of the drape (44%, P = 0.0002). Bacterial contamination of the operative microscope was found to be significant after spine surgery. Contamination was more common around the optic eyepieces, likely due to inadvertent touching of unsterile portions. Similarly, all regions above the eyepieces also have a propensity for contamination because of unknown contact with unsterile parts of the surgeon. Therefore, we believe that changing gloves after making adjustments to the optic eyepieces and avoid handling any portion of the drape above the eyepieces may decrease the risks of intraoperative contamination and possibly postoperative infection as well.
NASA Astrophysics Data System (ADS)
Aqeel Salim, Ali; Bidin, Noriah; Bakhtiar, Hazri; Krishna Ghoshal, Sib; Azawi, Mohammed Al; Krishnan, Ganesan
2018-05-01
Organic nanoparticles development is under exploration due to its beneficial applications in nanobiomedical and research interests. PLAL technique of Q-switched 1064-Nd: YAG (10 ns pulse duration, repetition rate 1 Hz and laser energy 20-100 mJ) has inherent advantages and rapid growth of nanoparticles when compared to conventional methods because of the controlled fabricated nanoparticles, stability, and purity. Cinnamon sticks as a target are immersed in 5 ml ethanol medium and irradiated by a laser beam for the growth process. The morphology, optical characteristic, and bonding structure of cinnamon nanoparticles (CNPs) are determined and evaluated by transmission electron microscope (TEM), UV-Visible spectroscopy and Fourier transform infrared spectroscopy (FTIR). Spherical, homogenous and high crystallinity CNPs was revealed within the particle size range of 2 - 28 nm. The absorption band was found in the ultraviolent region around 259 nm and 319 nm. The present of FTIR spectra confirmed that the nanoparticles were covered by plant secondary metabolites. The experimental findings revealed that the synthesize CNPs in ethanol has a potential for nanomedicine applications.
Shahid, Muhammad; Bukhari, Shazia Anwer; Gul, Yousra; Munir, Hira; Anjum, Fozia; Zuber, Mohammad; Jamil, Tahir; Zia, Khalid Mahmood
2013-11-01
This article is aimed to discuss the modification of guar gum through microwave irradiation by varying the time of irradiation. The characterization of the modified products was carried out using FTIR spectroscopic analysis. The FT-IR spectrum of the pure guar gum (GG) sample showed a broad peak at 3298 cm(-1) while the modified GG sample displayed a peak at 1541 cm(-1) which was absent in the crude sample. The X-ray diffraction (XRD) analysis confirmed the increase in crystallinity due to grafting of the sample with polyacrylamide (GG-g-PAM). Scanning electron microscope (SEM) images revealed that granular form of guar gum was changed into fibrillar structure after grafting. Thermo-gravimetric analysis of the modified samples was also carried out and discussed. The role of guar gum as a matrix for controlled release of drug triamcinolone was evaluated. The GG-acrylamide grafted samples presented a correlation between drug release and time of microwave exposure. The results revealed that such modified product has potential applications in colonic drug delivery system. Copyright © 2013 Elsevier B.V. All rights reserved.
Refilling of carbon nanotube cartridges for 3D nanomanufacturing
NASA Astrophysics Data System (ADS)
Bekarevich, Raman; Toyoda, Masami; Baba, Shuichi; Nakata, Toshihiko; Hirahara, Kaori
2016-03-01
Metal-filled carbon nanotubes (CNTs) are known to be used as pen-tip injectors for 3D manufacturing on the nanoscale. However, the CNT interior cannot accumulate enough material to fabricate complex metallic nanostructures. Therefore a method for refilling the CNT cartridge needs to be developed. The strategy for refilling of CNT cartridges is suggested in this study. Controlled growth of gold nanowires in the interior of isolated CNTs using a real-time manipulator installed in a transmission electron microscope is reported herein. The encapsulation process of discrete gold nanoparticles in the hollow spaces of open-ended multi-wall CNTs was evaluated in detail. The experimental results reveal that the serial loading of isolated gold nanoparticles allows the control of the length of the loaded nanowires with nanometer accuracy. Thermophoresis and the coalescence of gold nanoparticles are assumed to be the primary mechanisms responsible for gold loading into a CNT cartridge.Metal-filled carbon nanotubes (CNTs) are known to be used as pen-tip injectors for 3D manufacturing on the nanoscale. However, the CNT interior cannot accumulate enough material to fabricate complex metallic nanostructures. Therefore a method for refilling the CNT cartridge needs to be developed. The strategy for refilling of CNT cartridges is suggested in this study. Controlled growth of gold nanowires in the interior of isolated CNTs using a real-time manipulator installed in a transmission electron microscope is reported herein. The encapsulation process of discrete gold nanoparticles in the hollow spaces of open-ended multi-wall CNTs was evaluated in detail. The experimental results reveal that the serial loading of isolated gold nanoparticles allows the control of the length of the loaded nanowires with nanometer accuracy. Thermophoresis and the coalescence of gold nanoparticles are assumed to be the primary mechanisms responsible for gold loading into a CNT cartridge. Electronic supplementary information (ESI) available: Variations of loading of the initial nanoparticle into the CNT, movies demonstrating the processes of the loading of the initial nanoparticle and elongation of encapsulated nanowire. See DOI: 10.1039/c5nr08712k
Anisotropic type-I superconductivity and anomalous superfluid density in OsB2
NASA Astrophysics Data System (ADS)
Bekaert, J.; Vercauteren, S.; Aperis, A.; Komendová, L.; Prozorov, R.; Partoens, B.; Milošević, M. V.
2016-10-01
We present a microscopic study of superconductivity in OsB2, and discuss the origin and characteristic length scales of the superconducting state. From first-principles we show that OsB2 is characterized by three different Fermi sheets, and we prove that this fermiology complies with recent quantum-oscillation experiments. Using the found microscopic properties, and experimental data from the literature, we employ Ginzburg-Landau relations to reveal that OsB2 is a distinctly type-I superconductor with a very low Ginzburg-Landau parameter κ —a rare property among compound materials. We show that the found coherence length and penetration depth corroborate the measured thermodynamic critical field. Moreover, our calculation of the superconducting gap structure using anisotropic Eliashberg theory and ab initio calculated electron-phonon interaction as input reveals a single but anisotropic gap. The calculated gap spectrum is shown to give an excellent account for the unconventional behavior of the superfluid density of OsB2 measured in experiments as a function of temperature. This reveals that gap anisotropy can explain such behavior, observed in several compounds, which was previously attributed solely to a two-gap nature of superconductivity.
NASA Astrophysics Data System (ADS)
Pandey, J. C.; Choubey, P. N.; Raj, Manish
2008-07-01
The article presents the investigation results of inclusion bands generally formed toward the loose end/inner radius of continuously cast (CC) strands of thermomechanically treated (TMT) rebar grade cast through curved molds. The main analytical tool used for this purpose was an ultrasonic C-scan image analysis system to reveal this band, and the defects detected in this band using the preceding technique were further measured and analyzed in an optical microscope and a scanning electron microscope (SEM) using energy-dispersive system (EDS). The investigation results revealed the presence of macrolevel globular macroinclusions in the size range 50 to 711 μm. The main constituents of the globular inclusions were found to be SiO2 and MnO. Impact test results revealed reduction in ductility in these bands when compared with the billet material without inclusion band toward the opposite face from the inner radius face. In Charpy testing, reduction in the impact energy in these bands was found to be 0.2 kg m. It is important to monitor the severity of macroinclusions present in these bands to avoid the cracking of TMT rebars during hot rolling.
Anisotropic type-I superconductivity and anomalous superfluid density in OsB 2
Bekaert, Jonas; Vercauteren, S.; Aperis, A.; ...
2016-10-12
Here, we present a microscopic study of superconductivity in OsB 2, and discuss the origin and characteristic length scales of the superconducting state. From first-principles we show that OsB 2 is characterized by three different Fermi sheets, and we prove that this fermiology complies with recent quantum-oscillation experiments. Using the found microscopic properties, and experimental data from the literature, we employ Ginzburg-Landau relations to reveal that OsB 2 is a distinctly type-I superconductor with a very low Ginzburg-Landau parameter κ—a rare property among compound materials. We show that the found coherence length and penetration depth corroborate the measured thermodynamic criticalmore » field. Moreover, our calculation of the superconducting gap structure using anisotropic Eliashberg theory and ab initio calculated electron-phonon interaction as input reveals a single but anisotropic gap. The calculated gap spectrum is shown to give an excellent account for the unconventional behavior of the superfluid density of OsB 2 measured in experiments as a function of temperature. This reveals that gap anisotropy can explain such behavior, observed in several compounds, which was previously attributed solely to a two-gap nature of superconductivity.« less
Investigation of Structure and Property of Indian Cocos nucifera L. Fibre
NASA Astrophysics Data System (ADS)
Basu, Gautam; Mishra, Leena; Samanta, Ashis Kumar
2017-12-01
Structure and physico-mechanical properties of Cocos nucifera L. fibre from a specific agro-climatic region of India, was thoroughly studied. Fine structure of the fibre was examined by Fourier Transform Infra-Red (FTIR) spectroscopy, Thermo-Gravimetric Analysis (TGA), X-Ray Diffraction (XRD), component analysis, Scanning Electron Microscope (SEM) and optical microscope. SEM shows prominent longitudinal cracks and micro-pores on the surface. XRD shows a low degree of crystallinity (45%), bigger crystallite size, and even the presence of appreciable amount of non-cellulose matter. FTIR reveals presence of large quantities of hydroxyl, phenolic and aldehyde groups. Component and thermal analyses indicates presence of cellulose and lignin as major components. Physical parameters reveal that, fibres are highly variable in length (range 44-305 mm), and diameter (range 100-795 µm). Mechanical properties of the fibre viz. breaking tenacity, breaking extensibility, specific work of rupture, and coefficient of friction were measured. Microbial decomposition test under soil reveals excellent durability of coconut fibre which makes it appropriate for the application in geotextiles. Mass specific electrical resistance of 4 Ω-kg/m2 indicates its enhanced insulation as compared to the jute.
Brantley, William A; Guo, Wenhua; Clark, William A T; Iijima, Masahiro
2008-02-01
Previous temperature-modulated differential scanning calorimetry (TMDSC) study of nickel-titanium orthodontic wires revealed a large exothermic low-temperature peak that was attributed to transformation within martensitic NiTi. The purpose of this study was to use transmission electron microscopy (TEM) to verify this phase transformation in a clinically popular nickel-titanium wire, identify its mechanism and confirm other phase transformations found by TMDSC, and to provide detailed information about the microstructure of this wire. The 35 degrees C Copper nickel-titanium wire (Ormco) with cross-section dimensions of 0.016 in. x 0.022 in. used in the earlier TMDSC investigation was selected. Foils were prepared for TEM analyses by mechanical grinding, polishing, dimpling, ion milling and plasma cleaning. Standard bright-field and dark-field TEM images were obtained, along with convergent-beam electron diffraction patterns. A cryo-stage with the electron microscope (Phillips CM 200) permitted the specimen to be observed at -187, -45, and 50 degrees C, as well as at room temperature. Microstructures were also observed with an optical microscope and a scanning electron microscope. Room temperature microstructures had randomly oriented, elongated grains that were twinned. Electron diffraction patterns confirmed that phase transformations took place over temperature ranges previously found by TMDSC. TEM observations revealed a high dislocation density and fine-scale oxide particles, and that twinning is the mechanism for the low-temperature transformation in martensitic NiTi. TEM confirmed the low-temperature peak and other phase transformations observed by TMDSC, and revealed that twinning in martensite is the mechanism for the low-temperature peak. The high dislocation density and fine-scale oxide particles in the microstructure are the result of the wire manufacturing process.
Differential phase acoustic microscope for micro-NDE
NASA Technical Reports Server (NTRS)
Waters, David D.; Pusateri, T. L.; Huang, S. R.
1992-01-01
A differential phase scanning acoustic microscope (DP-SAM) was developed, fabricated, and tested in this project. This includes the acoustic lens and transducers, driving and receiving electronics, scanning stage, scanning software, and display software. This DP-SAM can produce mechanically raster-scanned acoustic microscopic images of differential phase, differential amplitude, or amplitude of the time gated returned echoes of the samples. The differential phase and differential amplitude images provide better image contrast over the conventional amplitude images. A specially designed miniature dual beam lens was used to form two foci to obtain the differential phase and amplitude information of the echoes. High image resolution (1 micron) was achieved by applying high frequency (around 1 GHz) acoustic signals to the samples and placing two foci close to each other (1 micron). Tone burst was used in this system to obtain a good estimation of the phase differences between echoes from the two adjacent foci. The system can also be used to extract the V(z) acoustic signature. Since two acoustic beams and four receiving modes are available, there are 12 possible combinations to produce an image or a V(z) scan. This provides a unique feature of this system that none of the existing acoustic microscopic systems can provide for the micro-nondestructive evaluation applications. The entire system, including the lens, electronics, and scanning control software, has made a competitive industrial product for nondestructive material inspection and evaluation and has attracted interest from existing acoustic microscope manufacturers.
Cruz-Ramírez, Miriam Elizabeth; Sulvarán-Victoria, Diana
2017-01-01
Introduction Microscopic haematuria is common in adults and it has been reported in 13% of postmenopausal women. Objective To evaluate the changes in urinary sediment after the use of vaginal conjugated oestrogens. Material and methods Postmenopausal women with vaginal dryness were studied. In all them a urinalysis was done, looking for density, pH, and the presence of leukocytes and erythrocytes. In order to be included in the study, all of the women had to have microscopic haematuria, considered as the presence of 3 or more erythrocytes in the urinary sediment. All received vaginally 1 g of conjugated equine oestrogens cream 3 times per week for one month, moment in which a new urinalysis was carried out and the same parameters were evaluated. Results Twenty-four women were studied. The median age was 62 years (40-83), and the time since menopause was 144 months (24-336). When comparing the values between baseline and end of treatment urinalyses, no significant differences in pH and urinary density were found. The number of leukocytes significantly decreased after treatment (3.0 [1-6] vs. 1.0 [1-6], p < 0.026), and the erythrocytes number decreased (4.5 [3-12] vs. 0.0 [0-2], p < 0.001). Conclusion In postmenopausal women with microscopic haematuria and vaginal dryness, it is worth considering administration of local oestrogen for one month, and after repeat the urine exam, before deciding to begin the microscopic haematuria study protocol. PMID:29507575
Quantitative orientation-independent differential interference contrast (DIC) microscopy
NASA Astrophysics Data System (ADS)
Shribak, Michael; LaFountain, James; Biggs, David; Inoué, Shinya
2007-02-01
We describe a new DIC technique, which records phase gradients within microscopic specimens independently of their orientation. The proposed system allows the generation of images representing the distribution of dry mass (optical path difference) in the specimen. Unlike in other forms of interference microscopes, this approach does not require a narrow illuminating cone. The orientation-independent differential interference contrast (OI-DIC) system can also be combined with orientation-independent polarization (OI-Pol) measurements to yield two complementary images: one showing dry mass distribution (which is proportional to refractive index) and the other showing distribution of birefringence (due to structural or internal anisotropy). With a model specimen used for this work -- living spermatocytes from the crane fly, Nephrotoma suturalis --- the OI-DIC image clearly reveals the detailed shape of the chromosomes while the polarization image quantitatively depicts the distribution of the birefringent microtubules in the spindle, both without any need for staining or other modifications of the cell. We present examples of a pseudo-color combined image incorporating both orientation-independent DIC and polarization images of a spermatocyte at diakinesis and metaphase of meiosis I. Those images provide clear evidence that the proposed technique can reveal fine architecture and molecular organization in live cells without perturbation associated with staining or fluorescent labeling. The phase image was obtained using optics having a numerical aperture 1.4, thus achieving a level of resolution never before achieved with any interference microscope.
NASA Astrophysics Data System (ADS)
William, R. V.; Sivaprakash, P.; Marikani, A.; Reddy, V. Raghavendra; Arumugam, S.
2018-02-01
We present here the experimental results of BiFe0.75Cr0.25O3 (BFCO) thin film deposited by sol-gel spin coating technique directly on Pt(111)/Ti/SiO2/Si substrate at different thicknesses. The crystal structure of BFCO has been investigated using X-ray diffraction which acts as a double perovskite structure with high crystallinity obtained at 400 °C. Further microscopic studies such as scanning electron microscope (SEM) with EDAX, transmission electron microscope (TEM) were also used in identifying the grain size and particle distribution over Pt (111) substrate. Atomic force microscopy (AFM) on the films at a different thickness (- 80 to - 250 nm) reveals that the surface roughness and other amplitude parameters increases with the increase in thickness signifying an increase of grain size with thickness. Increase in grain size and substrate clamping effect between the BFCO film and the substrate induces change in ferroelectric polarization and dielectric properties in relation to thickness effect. Similarly, decrease in magnetization from 9.241 emu/cm3 (- 80 nm) to 5.7791 emu/cm3 (- 250 nm) is attributed to the formation of anti-sites and anti-phase boundaries in the films. In addition, temperature dependence of magnetization reveals ferromagnetic super-exchange interaction of BFCO which is unlike the spin structure of antiferromagnetic BiFeO3.
Atomic Force Microscope Studies of the Fusion of Floating Lipid Bilayers
Abdulreda, Midhat H.; Moy, Vincent T.
2007-01-01
This study investigated the fusion of apposing floating bilayers of egg L-α-phosphatidylcholine (egg PC) or 1,2-dimyristoyl-sn-glycero-3-phosphocholine. Atomic force microscope measurements of fusion forces under different compression rates were acquired to reveal the energy landscape of the fusion process under varied lipid composition and temperature. Between compression rates of ∼1000 and ∼100,000 pN/s, applied forces in the range from ∼100 to ∼500 pN resulted in fusion of floating bilayers. Our atomic force microscope measurements indicated that one main energy barrier dominated the fusion process. The acquired dynamic force spectra were fit with a simple model based on the transition state theory with the assumption that the fusion activation potential is linear. A significant shift in the energy landscape was observed when bilayer fluidity and composition were modified, respectively, by temperature and different cholesterol concentrations (15% ≤ chol ≤ 25%). Such modifications resulted in a more than twofold increase in the width of the fusion energy barrier for egg PC and 1,2-dimyristoyl-sn-glycero-3-phosphocholine floating bilayers. The addition of 25% cholesterol to egg PC bilayers increased the activation energy by ∼1.0 kBT compared with that of bilayers with egg PC alone. These results reveal that widening of the energy barrier and consequently reduction in its slope facilitated membrane fusion. PMID:17400691
Atomic force microscope studies of the fusion of floating lipid bilayers.
Abdulreda, Midhat H; Moy, Vincent T
2007-06-15
This study investigated the fusion of apposing floating bilayers of egg L-alpha-phosphatidylcholine (egg PC) or 1,2-dimyristoyl-sn-glycero-3-phosphocholine. Atomic force microscope measurements of fusion forces under different compression rates were acquired to reveal the energy landscape of the fusion process under varied lipid composition and temperature. Between compression rates of approximately 1000 and approximately 100,000 pN/s, applied forces in the range from approximately 100 to approximately 500 pN resulted in fusion of floating bilayers. Our atomic force microscope measurements indicated that one main energy barrier dominated the fusion process. The acquired dynamic force spectra were fit with a simple model based on the transition state theory with the assumption that the fusion activation potential is linear. A significant shift in the energy landscape was observed when bilayer fluidity and composition were modified, respectively, by temperature and different cholesterol concentrations (15% < or = chol < or = 25%). Such modifications resulted in a more than twofold increase in the width of the fusion energy barrier for egg PC and 1,2-dimyristoyl-sn-glycero-3-phosphocholine floating bilayers. The addition of 25% cholesterol to egg PC bilayers increased the activation energy by approximately 1.0 k(B)T compared with that of bilayers with egg PC alone. These results reveal that widening of the energy barrier and consequently reduction in its slope facilitated membrane fusion.
NASA Astrophysics Data System (ADS)
Pavlos, George P.
2017-12-01
In this study, we present the highlights of complexity theory (Part I) and significant experimental verifications (Part II) and we try to give a synoptic description of complexity theory both at the microscopic and at the macroscopic level of the physical reality. Also, we propose that the self-organization observed macroscopically is a phenomenon that reveals the strong unifying character of the complex dynamics which includes thermodynamical and dynamical characteristics in all levels of the physical reality. From this point of view, macroscopical deterministic and stochastic processes are closely related to the microscopical chaos and self-organization. The scientific work of scientists such as Wilson, Nicolis, Prigogine, Hooft, Nottale, El Naschie, Castro, Tsallis, Chang and others is used for the development of a unified physical comprehension of complex dynamics from the microscopic to the macroscopic level. Finally, we provide a comprehensive description of the novel concepts included in the complexity theory from microscopic to macroscopic level. Some of the modern concepts that can be used for a unified description of complex systems and for the understanding of modern complexity theory, as it is manifested at the macroscopic and the microscopic level, are the fractal geometry and fractal space-time, scale invariance and scale relativity, phase transition and self-organization, path integral amplitudes, renormalization group theory, stochastic and chaotic quantization and E-infinite theory, etc.
Intraocular Gnathostoma spinigerum. Clinicopathologic study of two cases with review of literature.
Biswas, J; Gopal, L; Sharma, T; Badrinath, S S
1994-01-01
Live intraocular nematode is a rare occurrence that is mostly reported in Southeast Asian countries. Common nematodes that are seen live in the eye are microfilaria, Gnathostoma, and Angiostrongylus. Approximately 12 cases of intraocular gnathostomiasis have been reported in the literature. Two cases of intraocular gnathostoma, removed by vitrectomy in the first case and by paracentesis in the second case, are reported. Morphologic study of the parasites in wet preparation was performed under dissecting microscope and fixed in Karnovosky's fixative. Light microscopic and scanning electron microscopic studies were also performed. The first patient had anterior uveitis, multiple iris holes, and dense vitreous haze with fibrous proliferation over the optic disc. On resolution of the vitreous haze, a live worm was seen in the vitreous cavity. The second patient had anterior uveitis with secondary glaucoma, multiple iris holes, mild vitritis, and focal subretinal haemorrhage with subretinal tracts. Four days later a live worm was seen in the anterior chamber and removed. Microscopic study of the parasites from both patients revealed typical head bulb with four circumferential rows of hooklets, and fine cuticular spines were seen on the surface of the body. Iris holes, uveitis, and subretinal haemorrhage with subretinal tract can be characteristic features of intraocular gnathostomiasis. Identification of this parasite can be made by typical features, which can be identified on light and scanning electron microscopic study.
Caruso, Valentina; Cummaudo, Marco; Maderna, Emanuela; Cappella, Annalisa; Caudullo, Giorgio; Scarpulla, Valentina; Cattaneo, Cristina
2018-02-01
The present study aims to evaluate the preservation of the microstructure of skeletal remains collected from four different known burial sites (archaeological and contemporary). Histological analysis on undecalcified and decalcified thin sections was performed in order to assess which of the two techniques is more affected by taphonomic insults. A histological analysis was performed on both undecalcified and decalcified thin sections of 40 long bones and the degree of diagenetic change was evaluated using transmitted and polarized light microscopy according to the Oxford Histological Index (OHI). In order to test the optical behavior of bone tissue, thin sections were observed by polarized light microscopy and the intensity of birefringence was evaluated. The more ancient samples are generally characterized by a low OHI (0-1) with extensive microscopic focal destruction; recent samples exhibited a better preservation of bone micromorphology. When comparing undecalcified to decalcified thin sections, the latter showed an amelioration in the conservation of microscopic structure. As regards the birefringence, it was very low in all the undecalcified thin sections, whereas decalcification process seems to improve its visibility. The preservation of the bone microscopic structure appears to be influenced not only by age, but also by the burial context. Undecalcified bones appear to be more affected by taphonomical alterations, probably because of the thickness of the thin sections; on the contrary, decalcified thin sections proved to be able to tackle this issue allowing a better reading of the bone tissue. © 2017 Wiley Periodicals, Inc.
Synthesis of gold nanoparticles with graphene oxide.
Wang, Wenshuo; He, Dawei; Zhang, Xiqing; Duan, Jiahua; Wu, Hongpeng; Xu, Haiteng; Wang, Yongsheng
2014-05-01
Single sheets of functionalized graphene oxide are derived through chemical exfoliation of natural flake graphite. We present an effective synthetic method of graphene-gold nanoparticles hybrid nanocomposites. AFM (Atomic Force Microscope) was used to measure the thickness of the individual GO nanosheet. FTIR (Fourier transform infrared) spectroscopy was used to verify the attachment of oxygen functionalities on the surface of graphene oxide. TEM (Transmission Electron Microscope) data revealed the average diameters of the gold colloids and characterized the composite particles situation. Absorption spectroscopy showed that before and after synthesis the gold particle size did not change. Our studies indicate that the hybrid is potential substrates for catalysts and biosensors.
Mapping flexible protein domains at subnanometer resolution with the atomic force microscope.
Müller, D J; Fotiadis, D; Engel, A
1998-06-23
The mapping of flexible protein domains with the atomic force microscope is reviewed. Examples discussed are the bacteriorhodopsin from Halobacterium salinarum, the head-tail-connector from phage phi29, and the hexagonally packed intermediate layer from Deinococcus radiodurans which all were recorded in physiological buffer solution. All three proteins undergo reversible structural changes that are reflected in standard deviation maps calculated from aligned topographs of individual protein complexes. Depending on the lateral resolution (up to 0.8 nm) flexible surface regions can ultimately be correlated with individual polypeptide loops. In addition, multivariate statistical classification revealed the major conformations of the protein surface.
NASA Astrophysics Data System (ADS)
Raja, Anju M.; Xu, Shuoyu; Sun, Wanxin; Zhou, Jianbiao; Tai, Dean C. S.; Chen, Chien-Shing; Rajapakse, Jagath C.; So, Peter T. C.; Yu, Hanry
2010-09-01
Pulse-modulated second harmonic imaging microscopes (PM-SHIMs) exhibit improved signal-to-noise ratio (SNR) over conventional SHIMs on sensitive imaging and quantification of weak collagen signals inside tissues. We quantify the spatial distribution of sparse collagen inside a xenograft model of human acute myeloid leukemia (AML) tumor specimens treated with a new drug against receptor tyrosine kinase (ABT-869), and observe a significant increase in collagen area percentage, collagen fiber length, fiber width, and fiber number after chemotherapy. This finding reveals new insights into tumor responses to chemotherapy and suggests caution in developing new drugs and therapeutic regimens against cancers.
The future of electron microscopy
Zhu, Yimei; Durr, Hermann
2015-04-01
Seeing is believing. So goes the old adage and seen evidence is undoubtedly satisfying because it can be interpreted easily, though not always correctly. For centuries, humans have developed such instruments as telescopes that observe the heavens and microscopes that reveal bacteria and viruses. The 2014 Nobel Prize in Chemistry was awarded to Eric Betzig, Stefan Hell, and William Moerner for their foundational work on superresolution fluorescence microscopy in which they overcame the Abbe diffraction limit for the resolving power of conventional light microscopes. (See Physics Today, December 2014, page 18.) That breakthrough enabled discoveries in biological research and testifiesmore » to the importance of modern microscopy.« less
NASA Astrophysics Data System (ADS)
Terabe, K.; Takekawa, S.; Nakamura, M.; Kitamura, K.; Higuchi, S.; Gotoh, Y.; Gruverman, A.
2002-09-01
We have investigated the ferroelectric domain structure formed in a Sr0.61Ba0.39Nb2O6 single crystal by cooling the crystal through the Curie point. Imaging the etched surface structure using a scanning force microscope (SFM) in both the topographic mode and the piezoresponse mode revealed that a multidomain structure of nanoscale islandlike domains was formed. The islandlike domains could be inverted by applying an appropriate voltage using a conductive SFM tip. Furthermore, a nanoscale periodically inverted-domain structure was artificially fabricated using the crystal which underwent poling treatment.
Yoshizawa, Shunsuke; Kim, Howon; Kawakami, Takuto; Nagai, Yuki; Nakayama, Tomonobu; Hu, Xiao; Hasegawa, Yukio; Uchihashi, Takashi
2014-12-12
We have studied the superconducting Si(111)-(√7×√3)-In surface using a ³He-based low-temperature scanning tunneling microscope. Zero-bias conductance images taken over a large surface area reveal that vortices are trapped at atomic steps after magnetic fields are applied. The crossover behavior from Pearl to Josephson vortices is clearly identified from their elongated shapes along the steps and significant recovery of superconductivity within the cores. Our numerical calculations combined with experiments clarify that these characteristic features are determined by the relative strength of the interterrace Josephson coupling at the atomic step.
NASA Astrophysics Data System (ADS)
Chen, CHAI; Yiik Diew, WONG
2017-02-01
This study provides an integrated strategy, encompassing microscopic simulation, safety assessment, and multi-attribute decision-making, to optimize traffic performance at downstream merging area of signalized intersections. A Fuzzy Cellular Automata (FCA) model is developed to replicate microscopic movement and merging behavior. Based on simulation experiment, the proposed FCA approach is able to provide capacity and safety evaluation of different traffic scenarios. The results are then evaluated through data envelopment analysis (DEA) and analytic hierarchy process (AHP). Optimized geometric layout and control strategies are then suggested for various traffic conditions. An optimal lane-drop distance that is dependent on traffic volume and speed limit can thus be established at the downstream merging area.
Naval Research Laboratory Major Facilities 2008
2008-10-01
Development Laboratory • Secure Supercomputing Facility • CBD/Tilghman Island IR Field Evaluation Facility • Ultra-Short-Pulse Laser Effects Research...EMI Test Facility • Proximity Operations Testbed GENERAL INFORMATION • Maps EX EC U TI V E D IR EC TO RA TE Code 1100 – Institute for Nanoscience...facility: atomic force microscope (AFM); benchtop transmission electron microscope (TEM); cascade probe station; critical point dryer ; dual beam focused
Advance in quality assessment of Chinese materia medica using microscopic and morphological methods.
Miao, Xiao-Su; Cui, Qing-Yu; Wang, Zhao-Yi; Liu, Xiao-Na; Zhao, An-Bang; Qiao, Yan-Jiang; Wu, Zhi-Sheng
2017-09-01
Quality evaluation plays a vital role in ensuring safety and effectiveness of Chinese materia medica (CMM). Microscopic and morphological technologies can be used to distinguish CMM's characteristics, such as shape, size, texture, section, and smell, for authenticity and quality control of CMM. The microscopic and morphological applications of novel micro-technology, colorimeter, and texture analyzer for CMM identification are summarized and the future prospect is discussed in this paper. Various styles and complex sources of CMM are systemically reviewed, including cormophyte medicinal materials, fruit and seeds, pollen grain, and spore materials. Copyright © 2017 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.
Dang-Trinh, Minh-Anh; Angeles, Jose Ma M; Moendeg, Kharleezelle J; Macalanda, Adrian Miki C; Higuchi, Luna; Oto, Chiho; Kirinoki, Masashi; Chigusa, Yuichi; Kawazu, Shin-Ichiro
2018-06-01
Schistosoma japonicum, causing zoonotic intestinal schistosomiasis, is found in China, the Philippines and parts of Indonesia. Severe disease manifestations are basically due to the deposition of eggs in some vital organs such as the liver, spleen and brain. Traditionally, histopathological microscopic examination of the egg burden was used to evaluate the intensity of infection in the affected organs. However, this technique is laborious, time-consuming and requires trained personnel. In this study, real time PCR targeting the mitochondrial NADH dehydrogenase I gene was used to compare with microscopic examination of tissue sections in evaluating the egg burdens in different affected organs. Livers, spleens and brains of the S. japonicum infected mice after 8 and 18 weeks post-infection (p.i) were harvested and examined. Results showed that there were statistically significant correlations between the egg burden evaluated by tissue section examination, and the Ct values of the real time PCR of livers with heavy egg burden at 8 (r = -0.81) and 18 (r = -0.80) weeks p.i. Furthermore, a correlation (r = -0.56) between the egg burden assessed by the microscopic examination and Ct value of the real time PCR of spleens with moderate egg burden after 18 weeks p.i and not 8 weeks p.i was also observed. Brains with low egg burden showed no schistosome eggs in the microscopic examination, however one sample tested positive by real time PCR. These results suggested that real time PCR is useful in evaluating schistosome egg burden in the organs of the experimentally infected mice model that will give further insights into the pathology of schistosomiasis. Copyright © 2018 Elsevier Inc. All rights reserved.
Nasal rhinosporidiosis in a mule.
Berrocal, Alexis; López, Alfonso
2007-03-01
A mass was removed from the nostril of a mule that exhibited unilateral epistaxis and nasal discharge. Impression smears revealed oval structures consistent with spores of Rhinosporidium seeberi. Microscopically, the mass was composed of fibrovascular granulomatous tissue containing sporangia R. seeberi. Surgical excision and antifungal treatment proved curative.
Diffraction-limited IR Microspectroscopy with IRENI
J. Sedlmair; B. Illman; M. Unger; C. Hirschmugl
2012-01-01
In a unique way, IRENI (Infrared environmental Imaging), operated at the Synchrotron Radiation Center in Madison, combines IR spectroscopy and IR imaging, revealing the chemical morphology of a sample. Most storage ring based IR confocal microscopes have to overcome a trade-off between spatial resolution versus...
[Syphilitic pleuritis. Description of a clinical case].
Cattini, G C; Greco, N; Tosto, L; Falcieri, E; Biagini, G
1983-02-25
A rare case of luetic pleurisy diagnosed in a patient with tertiary syphilis, when the aetiological agent was discovered in the pleuritic exudate is described. The spirochaetes, first revealed by dark field microscopy, were studied further under the electron microscope, using negative colouring and fine sections.
Yaghoubi, Ali; Pourjam, Ebrahim; Álvarez-Ortega, Sergio; Liébanas, Gracia; Atighi, Mohammad Reza; Pedram, Majid
2016-09-01
Discopersicus iranicus n. gen., n. comb., previously described from Iran as a new species under the genus Discotylenchus , is illustrated using light microscope and scanning electron microscope (SEM) observations and further studied using molecular characters. SEM studies revealed the newly proposed genus has oblique amphidial apertures on the lateral sides of the lip region. SEM images are also provided for two species of Discotylenchus , namely D. discretus and D. brevicaudatus , as the first SEM study of the genus . These results confirmed longitudinal amphidial aperture type on lateral sides of the lip region in genus Discotylenchus , as noted by Siddiqi while erecting the genus with D. discretus as the type species . Molecular phylogenetic analyses using partial small subunit (SSU) and large subunit (LSU) rDNA sequences revealed the affinity of the genus Discopersicus n. gen. with members of the subfamily Boleodorinae, as supported by morphological characters (mainly, the oblique amphidial opening).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Shan, E-mail: coralgao@hotmail.com; Engineering Ceramics Key Laboratory of Shandong Province, Shandong University, Jinan 250061; Sun, Kangning, E-mail: sunkangning@sdu.edu.cn
Highlights: ► We succeeded in synthesizing hydroxyapatite nano fibers by a chemical method. ► The reaction temperature is only 90 °C. ► The synthetic hydroxyapatite nano fiber is single crystal. - Abstract: We report a novel chemical precipitation route for the synthesis of hydroxyapatite (Ca{sub 10}(PO{sub 4}){sub 6}(OH){sub 2}, HA) fibers using surfactants as templates. Fourier transform infrared spectroscopy (FTIR) and powder X-ray diffraction (PXRD) reveal the characteristic peaks of HA. Transmission electron microscope (TEM) and high-resolution TEM revealed the nano structure, crystallinity and morphology of the HA fibers. The morphology of the HA fibers after calcinations were characterized bymore » scanning electron microscope (SEM). Br{sup −} ions were quickly replaced by the excess PO{sub 4}{sup 3−} ions in the solution after the addition of cetyltrime-thylammonium bromide (CTAB). Meanwhile, CTAB formed a rod-like micelles. Precursors reacted with PO{sub 4}{sup 3−} at the surface of CTAB micelles and finally formed the nanofiber structure.« less
Larosa, Claudio; Salerno, Marco; de Lima, Juliana Silva; Merijs Meri, Remo; da Silva, Milena Fernandes; de Carvalho, Luiz Bezerra; Converti, Attilio
2018-08-01
Incorporating enzymes into calcium alginate beads is an effective method to immobilise them and to preserve, at the same time, their catalytic activity. Sodium alginate was mixed with Aspergillus ficuum tannase in aqueous solution, and tannase-loaded calcium alginate beads were prepared using a simple droplet-based microfluidic system. Extensive experimental analysis was carried out to characterise the samples. Microscopic imaging revealed morphological differences between the surfaces of bare alginate matrix and tannase-loaded alginate beads. Thermal analysis allowed assessing the hydration contents of alginate and revealed the presence of tannase entrapped in the loaded beads, which was confirmed by vibrational spectroscopy. X-ray diffraction allowed us to conclude that alginate of tannase-loaded beads is not crystalline, which would make them suitable as carriers for possible controlled release. Moreover, they could be used in food applications to improve tea quality or clarify juices. Copyright © 2018 Elsevier B.V. All rights reserved.
Nair, P N
1983-01-01
A crypto-lymphatic unit was observed at the left lateral aspect of the uvula of a mature female monkey, Macaca fascicularis. A light- and transmission electron-microscopic investigation revealed that the lumen of the crypt was filled with bacteria, desquamated epithelial cells, lymphocytes and neutrophils. The non-keratinized stratified squamous epithelium of the crypt was fragmented and showed heavy mononuclear cell infiltration and surface discontinuities, exposing lymphoid cells to foreign material. The lymphatic parenchyma consisted of organized lymphatic tissue including germinal centres. The resident cell population included lymphocytes of varying size, blastforming B- and T-lymphocytes and two types of reticular cells resembling the fibroblastic reticulum cell and the follicular dendritic cell, respectively. Occasionally granulocytes were encountered. At its base and laterally the crypto-lymphatic unit was ensheathed by a thin connective tissue capsule. Three other monkeys of the same species failed to reveal similar structures at the same site.
Srinivasan, Vivek J.; Mandeville, Emiri T.; Can, Anil; Blasi, Francesco; Climov, Mihail; Daneshmand, Ali; Lee, Jeong Hyun; Yu, Esther; Radhakrishnan, Harsha; Lo, Eng H.; Sakadžić, Sava; Eikermann-Haerter, Katharina; Ayata, Cenk
2013-01-01
Progress in experimental stroke and translational medicine could be accelerated by high-resolution in vivo imaging of disease progression in the mouse cortex. Here, we introduce optical microscopic methods that monitor brain injury progression using intrinsic optical scattering properties of cortical tissue. A multi-parametric Optical Coherence Tomography (OCT) platform for longitudinal imaging of ischemic stroke in mice, through thinned-skull, reinforced cranial window surgical preparations, is described. In the acute stages, the spatiotemporal interplay between hemodynamics and cell viability, a key determinant of pathogenesis, was imaged. In acute stroke, microscopic biomarkers for eventual infarction, including capillary non-perfusion, cerebral blood flow deficiency, altered cellular scattering, and impaired autoregulation of cerebral blood flow, were quantified and correlated with histology. Additionally, longitudinal microscopy revealed remodeling and flow recovery after one week of chronic stroke. Intrinsic scattering properties serve as reporters of acute cellular and vascular injury and recovery in experimental stroke. Multi-parametric OCT represents a robust in vivo imaging platform to comprehensively investigate these properties. PMID:23940761
Diffusion MRI at 25: Exploring brain tissue structure and function
Bihan, Denis Le; Johansen-Berg, Heidi
2013-01-01
Diffusion MRI (or dMRI) came into existence in the mid-1980s. During the last 25 years, diffusion MRI has been extraordinarily successful (with more than 300,000 entries on Google Scholar for diffusion MRI). Its main clinical domain of application has been neurological disorders, especially for the management of patients with acute stroke. It is also rapidly becoming a standard for white matter disorders, as diffusion tensor imaging (DTI) can reveal abnormalities in white matter fiber structure and provide outstanding maps of brain connectivity. The ability to visualize anatomical connections between different parts of the brain, non-invasively and on an individual basis, has emerged as a major breakthrough for neurosciences. The driving force of dMRI is to monitor microscopic, natural displacements of water molecules that occur in brain tissues as part of the physical diffusion process. Water molecules are thus used as a probe that can reveal microscopic details about tissue architecture, either normal or in a diseased state. PMID:22120012
Anatomy of a Nanoscale Conduction Channel Reveals the Mechanism of a High-Performance Memristor
NASA Astrophysics Data System (ADS)
Miao, Feng; Strachan, John Paul; Yang, J. Joshua; Yi, Wei; Goldfarb, Ilan; Zhang, M.-X.; Torrezan, Antonio C.; Eschbach, Peter; Kelley, Ronald D.; Medeiros-Ribeiro, Gilberto; Williams, R. Stanley
2012-02-01
Two major challenges for resistance memory devices (memristors) based on conductivity changes in oxide materials are better performance and understanding of the microscopic picture of the switching. After researchers' relentless pursuit for years, tantalum oxide-based memristors have rapidly risen to be the top candidate, showing fast speed, high endurance and excellent scalability. While the microscopic picture of these devices remains obscure, by employing a precise method for locating and directly visualizing the conduction channel, here we observed a nanoscale channel consisting of an amorphous Ta(O) solid solution surrounded by crystalline Ta2O5. Structural and chemical analyses of the channel combined with temperature dependent transport measurements revealed a unique resistance switching mechanism: the modulation of the channel elemental composition, and thus the conductivity, by the cooperative influence of drift, diffusion and thermophoresis, which seem to enable the high switching performance observed. (Miao*, Strachan*, Yang* et al., Advanced Materials. DOI: 10.1002/adma201103379 (2011))
Lu, Mao; Ran, Yuping; Dai, Yaling; Lei, Song; Zhang, Chaoliang; Zhuang, Kaiwen; Hu, Wenying
2016-01-01
This study was aimed to explain the formation mechanisms of corkscrew hairs and cigarette-ash-shaped hairs observed by dermoscopy of tinea capitis. In the present work, the ultrastructure of the involved hairs collected from a girl with tinea capitis caused by Trichophyton violaceum was observed by scanning electron microscope (SEM) and transmission electron microscope (TEM). SEM observation of the corkscrew hair revealed bent hair shaft and asymmetrically disrupted cuticle layer. TEM findings demonstrated the hair shaft became weak. The corkscrew hairs closely covered by scales on the scalp were observed under dermoscopy. We speculate that the formation of corkscrew hairs is a result of a combination of internal damage due to hair degradation by T. violaceum and external resistance due to scales covering the hair. SEM observation of the cigarette-ash-shaped hair revealed irregularly disrupted and incompact end, which might represent the stump of the broken corkscrew hair after treatment. © Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Lin, Yung-Chi; Shih, Toung-Yi; Tien, Shih-Kang; Duh, Jenq-Gong
2007-11-01
Interfacial morphologies and microstructure of Sn-3Ag-0.5Cu/Ni-P under bump metallization (UBM) with various phosphorous contents were investigated by transmission electron microscope (TEM) and field emission electron probe microanalyzer (FE-EPMA). It was revealed that as the Ni-Sn-P compound was formed between the solder matrix and Ni-P UBM, the conventionally so-called phosphorous-rich (P-rich) layer was transformed to a series of layer compounds, including Ni3P, Ni12P5 and Ni2P. The relationship between Ni-Sn-P formation and evolution of P-rich layers was probed by electron microscopic characterization with the aid of the phase diagram of Ni-P. On the basis of the TEM micrograph, the selected area diffraction (SAD) pattern, and the FE-EPMA results, the detailed phase evolution of P-rich layers in the SnAgCu/Ni-P joint was revealed and proposed.
Demonstration of bacterial biofilms in culture-negative silicone stent and jones tube.
Parsa, Kami; Schaudinn, Christoph; Gorur, Amita; Sedghizadeh, Parish P; Johnson, Thomas; Tse, David T; Costerton, John W
2010-01-01
To demonstrate the presence of bacterial biofilms on a dacryocystorhinostomy silicone stent and a Jones tube. One dacryocystorhinostomy silicone stent and one Jones tube were removed from 2 patients who presented with an infection of their respective nasolacrimal system. Cultures were obtained, and the implants were processed for scanning electron microscopy and confocal laser scanning microscopy, advanced microscopic methods that are applicable for detection of uncultivable biofilm organisms. Routine bacterial cultures revealed no growth, but bacterial biofilms on outer and inner surfaces of both implants were confirmed by advanced microscopic techniques. To the authors' knowledge, this is the first article that documents the presence of biofilms on a Crawford stent or a Jones tube on patients who presented with infections involving the nasolacrimal system. Although initial cultures revealed absence of any bacterial growth, confocal laser scanning microscopy and scanning electron microscopy documented bacterial colonization. Clinicians should consider the role of biofilms and the limitation of our standard culturing techniques while treating patients with device- or implant-related infections.
Correction of image drift and distortion in a scanning electron microscopy.
Jin, P; Li, X
2015-12-01
Continuous research on small-scale mechanical structures and systems has attracted strong demand for ultrafine deformation and strain measurements. Conventional optical microscope cannot meet such requirements owing to its lower spatial resolution. Therefore, high-resolution scanning electron microscope has become the preferred system for high spatial resolution imaging and measurements. However, scanning electron microscope usually is contaminated by distortion and drift aberrations which cause serious errors to precise imaging and measurements of tiny structures. This paper develops a new method to correct drift and distortion aberrations of scanning electron microscope images, and evaluates the effect of correction by comparing corrected images with scanning electron microscope image of a standard sample. The drift correction is based on the interpolation scheme, where a series of images are captured at one location of the sample and perform image correlation between the first image and the consequent images to interpolate the drift-time relationship of scanning electron microscope images. The distortion correction employs the axial symmetry model of charged particle imaging theory to two images sharing with the same location of one object under different imaging fields of view. The difference apart from rigid displacement between the mentioned two images will give distortion parameters. Three-order precision is considered in the model and experiment shows that one pixel maximum correction is obtained for the employed high-resolution electron microscopic system. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.
NASA Astrophysics Data System (ADS)
Foley, Andrew; Alam, Khan; Lin, Wenzhi; Wang, Kangkang; Chinchore, Abhijit; Corbett, Joseph; Savage, Alan; Chen, Tianjiao; Shi, Meng; Pak, Jeongihm; Smith, Arthur
2014-03-01
A custom low-temperature (4.2 K) scanning tunneling microscope system has been developed which is combined directly with a custom molecular beam epitaxy facility (and also including pulsed laser epitaxy) for the purpose of studying surface nanomagnetism of complex spintronic materials down to the atomic scale. For purposes of carrying out spin-polarized STM measurements, the microscope is built into a split-coil, 4.5 Tesla superconducting magnet system where the magnetic field can be applied normal to the sample surface; since, as a result, the microscope does not include eddy current damping, vibration isolation is achieved using a unique combination of two stages of pneumatic isolators along with an acoustical noise shield, in addition to the use of a highly stable as well as modular `Pan'-style STM design with a high Q factor. First 4.2 K results reveal, with clear atomic resolution, various reconstructions on wurtzite GaN c-plane surfaces grown by MBE, including the c(6x12) on N-polar GaN(0001). Details of the system design and functionality will be presented.
Husmann, Polly R; O'Loughlin, Valerie Dean; Braun, Mark W
2009-10-01
This study compares overall laboratory averages and individual test scores along with a student survey to determine the effects of using virtual microscopy in place of optical microscopes in a large undergraduate human anatomy course. T-tests revealed that the first two laboratory examinations (of four) and the overall laboratory averages were significantly increased compared with the previous year. We hypothesize that this is due to students' ability to use and understand the technology quickly as opposed to learning how to maneuver an optical microscope. Students also responded positively in a survey about the virtual microscope, indicating that increased accessibility, ease of use, and the ability to understand the material were important components of the virtual microscope. In addition, an increase in student collaboration was noted because multiple students were able to view the image at a time. This level of acceptance of virtual microscopy has been reported in previous studies, though this level of increased examination scores is rare. We attribute this to differences between the medical students, with whom this technology has been researched in the past, and undergraduate introductory students.
Microscopic relaxations in a protein sustained down to 160 K in a non-glass forming organic solvent
Mamontov, Eugene; O'Neil, Hugh
2016-05-03
In this paper, we have studied microscopic dynamics of a protein in carbon disulfide, a non-glass forming solvent, down to its freezing temperature of ca. 160 K. We have utilized quasielastic neutron scattering. A comparison of lysozyme hydrated with water and dissolved in carbon disulfide reveals a stark difference in the temperature dependence of the protein's microscopic relaxation dynamics induced by the solvent. In the case of hydration water, the common protein glass-forming solvent, the protein relaxation slows down in response to a large increase in the water viscosity on cooling down, exhibiting a well-known protein dynamical transition. The dynamicalmore » transition disappears in non-glass forming carbon disulfide, whose viscosity remains a weak function of temperature all the way down to freezing at just below 160 K. The microscopic relaxation dynamics of lysozyme dissolved in carbon disulfide is sustained down to the freezing temperature of its solvent at a rate similar to that measured at ambient temperature. Finally, our results demonstrate that protein dynamical transition is not merely solvent-assisted, but rather solvent-induced, or, more precisely, is a reflection of the temperature dependence of the solvent's glass-forming dynamics.« less
Effect of silica nanoparticle filler on microscopic polymer α-relaxation dynamics
NASA Astrophysics Data System (ADS)
Saito, Makina; Mashita, Ryo; Kishimoto, Hiroyuki; Masuda, Ryo; Yoda, Yoshitaka; Seto, Makoto
2017-11-01
Tyre rubber has been continuously developed to improve its performance, but the microscopic mechanisms behind these improvements, e.g. by adding nanoparticles to the rubber, are still not fully understood. We study the microscopic polymer dynamics of a rubber nanocomposite system consisting of polymer polybutadiene with 20 volume% of silica nanoparticles with diameters of 100 nm via quasi-elastic scattering experiments using gamma-ray time-domain interferometry. The result shows that the presence of silica nanoparticles caused the inter-chain α-relaxation dynamics to slow down in a shallowly supercooled state suggesting that the presence of the nanoparticles that came in contact with the polymer controlled the timescale of the polymer's α-relaxation dynamics. Conversely, the presence of nanoparticles less affects the dynamics in a lower temperature region near T g. It is consistent with the result of the differential scanning calorimetry study showing negligible T g difference among the pure polymer and the nanocomposite system. It also shows that the quasi-elastic scattering experiment can be used to reveal the polymer dynamics in nanocomposites and is appropriate for characterising their microscopic dynamics for the purpose of improving tyre performance.
NASA Astrophysics Data System (ADS)
Jiang, N.; Deguchi, M.; Wang, C. L.; Won, J. H.; Jeon, H. M.; Mori, Y.; Hatta, A.; Kitabatake, M.; Ito, T.; Hirao, T.; Sasaki, T.; Hiraki, A.
1997-04-01
A transmission electron microscope (TEM) study of ion-implanted chemical-vapor-deposited (CVD) diamond is presented. CVD diamond used for transmission electron microscope observation was directly deposited onto Mo TEM grids. As-deposited specimens were irradiated by C (100 keV) ions at room temperature with a wide range of implantation doses (10 12-10 17/cm 2). Transmission electron diffraction (TED) patterns indicate that there exists a critical dose ( Dc) for the onset of amorphization of CVD diamond as a result of ion induced damage and the value of critical dose is confirmed to be about 3 × 10 15/cm 2. The ion-induced transformation process is clearly revealed by high resolution electron microscope (HREM) images. For a higher dose implantation (7 × 10 15/cm 2) a large amount of diamond phase is transformed into amorphous carbon and many tiny misoriented diamond blocks are found to be left in the amorphous solid. The average size of these misoriented diamond blocks is only about 1-2 nm. Further bombardment (10 17/cm 2) almost kills all of the diamond phase within the irradiated volume and moreover leads to local formation of micropolycrystalline graphite.
Complexity theory and physical unification: From microscopic to oscopic level
NASA Astrophysics Data System (ADS)
Pavlos, G. P.; Iliopoulos, A. C.; Karakatsanis, L. P.; Tsoutsouras, V. G.; Pavlos, E. G.
During the last two decades, low dimensional chaotic or self-organized criticality (SOC) processes have been observed by our group in many different physical systems such as space plasmas, the solar or the magnetospheric dynamics, the atmosphere, earthquakes, the brain activity as well as in informational systems. All these systems are complex systems living far from equilibrium with strong self-organization and phase transition character. The theoretical interpretation of these natural phenomena needs a deeper insight into the fundamentals of complexity theory. In this study, we try to give a synoptic description of complexity theory both at the microscopic and at the oscopic level of the physical reality. Also, we propose that the self-organization observed oscopically is a phenomenon that reveals the strong unifying character of the complex dynamics which includes thermodynamical and dynamical characteristics in all levels of the physical reality. From this point of view, oscopical deterministic and stochastic processes are closely related to the microscopical chaos and self-organization. In this study the scientific work of scientists such as Wilson, Nicolis, Prigogine, Hooft, Nottale, El Naschie, Castro, Tsallis, Chang and others is used for the development of a unified physical comprehension of complex dynamics from the microscopic to the oscopic level.
Keratinocytes in culture accumulate phagocytosed melanosomes in the perinuclear area.
Ando, Hideya; Niki, Yoko; Yoshida, Masaki; Ito, Masaaki; Akiyama, Kaoru; Kim, Jin-Hwa; Yoon, Tae-Jin; Lee, Jeung-Hoon; Matsui, Mary S; Ichihashi, Masamitsu
2010-02-01
There are many techniques for evaluating melanosome transfer to keratinocytes but the spectrophotometric quantification of melanosomes incorporated by keratinocyte phagocytosis has not been previously reported. Here we describe a new method that allows the spectrophotometric visualization of melanosome uptake by normal human keratinocytes in culture. Fontana-Masson staining of keratinocytes incubated with isolated melanosomes showed the accumulation of incorporated melanosomes in the perinuclear areas of keratinocytes within 48 h. Electron microscopic observations of melanosomes ingested by keratinocytes revealed that many phagosomes containing clusters of melanosomes or their fragments were localized in the perinuclear area. A known inhibitor of keratinocyte phagocytosis which inhibits protease-activated receptor-2, i.e., soybean trypsin inhibitor, decreased melanosome uptake by keratinocytes in a dose-dependent manner. These data suggest that our method is a useful model to quantitate keratinocyte phagocytosis of melanosomes visually in vitro.
NASA Astrophysics Data System (ADS)
Imantalab, O.; Fattah-alhosseini, A.; Keshavarz, M. K.; Mazaheri, Y.
2016-02-01
In this work, electrochemical behavior of annealed (micro-) and nano-grained pure copper (fabricated by accumulative roll bonding process) in phosphate buffer solutions of various pH values ranging from 10.69 to 12.59 has been studied. Before any electrochemical measurements, evaluation of microstructure was obtained by optical microscope and transmission electron microscopy. To investigate the electrochemical behavior of the samples, the potentiodynamic polarization, Mott-Schottky analysis, and electrochemical impedance spectroscopy (EIS) were carried out. Potentiodynamic polarization plots and EIS measurements revealed that as a result of grain refinement, the passive behavior of the nano-grained sample was improved compared to that of annealed pure copper. Also, Mott-Schottky analysis indicated that the passive films behaved as p-type semiconductors and grain refinement did not change the semiconductor type of passive films.
NASA Astrophysics Data System (ADS)
Xu, Wenhua; Wang, Zhenyu; Han, En-Hou; Liu, Chunbo
2017-12-01
The failure behavior for two kinds of phenolic-epoxy/tetraglycidyl metaxylediamine composite coatings in 60 °C borax aqueous solution was evaluated using electrochemical methods (EIS) combined with scanning electron microscopy, confocal laser scanning microscope, water immersion test, and Raman spectrum. The main focus was on the effect of curing agent on the corrosion protection of coatings. Results revealed that the coating cured by phenolic modified aromatic amine possessed more compact cross-linked structure, better wet adhesion, lower water absorption (0.064 mg h-1 cm-2) and its impedance values was closed to 108 Ω cm2 after immersion for 576 h, while the coating cured by modified aromatic ring aliphatic amine was lower than 105 Ω cm2. The corrosion mechanism of the two coatings is discussed.
Yang, Hui-Hui; Wang, Xi-Shu; Wang, Ya-Ming; Wang, Yan-Ling; Zhang, Zhi-Hao
2017-01-01
Rotating bending fatigue tests have been performed to evaluate the corrosion fatigue performance and its influence factors of 7075-T7351 Al alloy in different media, namely air and a 5.0 wt % NaCl aqueous solution. All samples were coated by microarc oxidation (MAO) coating technology; some samples were followed by an epoxy resin pore-sealing treatment. Microscopic analyses of the surfaces and fracture cross-sections of samples were carried out. The results reveal that the sample with a MAO coating of 10 μm thickness and pore-sealing treatment by epoxy resin possesses optimal corrosion fatigue performance in the different media. The MAO coating with a pore-sealing treatment significantly improves the corrosion fatigue limit of 7075-T7351 Al alloy. PMID:28772970
Evaluation of blood oxidant/antioxidant balance in dogs with sarcoptic mange.
Camkerten, Ilker; Sahin, T; Borazan, G; Gokcen, A; Erel, O; Das, A
2009-04-06
The aim of this study was to investigate of oxidant/antioxidant balance in dogs with sarcoptic mange. The study materials consisted of totally 30 cross-breed male dogs; 15 with sarcoptic mange (study group) and 15 healthy as control. Blood samples for analyses were taken from control and study group. In study group, microscopic examination of dermal scrapings of 15 dogs revealed S. scabies. Lipid hydroperoxide level, total oxidant status and oxidative stress index in dogs with sarcoptic mange were higher (P<0.01, P<0.01 and P<0.05, respectively) than the control. Otherwise; sulphydril levels in dogs with sarcoptic mange were lower (P<0.05) than that of control. No significant differences were observed in total antioxidant capacity between groups. Our results suggest a possible relationship between oxidant/antioxidant imbalance and sarcoptic mange infestation in dogs.
Cieślik, Monika; Kot, Marcin; Reczyński, Witold; Engvall, Klas; Rakowski, Wiesław; Kotarba, Andrzej
2012-01-01
The mechanical and protective properties of parylene N and C coatings (2-20 μm) on stainless steel 316L implant materials were investigated. The coatings were characterized by scanning electron and confocal microscopes, microindentation and scratch tests, whereas their protective properties were evaluated in terms of quenching metal ion release from stainless steel to simulated body fluid (Hanks solution). The obtained results revealed that for parylene C coatings, the critical load for initial cracks is 3-5 times higher and the total metal ions release is reduced 3 times more efficiently compared to parylene N. It was thus concluded that parylene C exhibits superior mechanical and protective properties for application as a micrometer coating material for stainless steel implants. Copyright © 2011 Elsevier B.V. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Sunshine trees (Senna surattensis Burm.) exhibiting unusual stem fasciation symptoms were observed in Yunnan, China. Morphological abnormalities of the affected plants included enlargement and flattening of stems and excessive proliferation of shoots. An electron microscopic investigation revealed...
USDA-ARS?s Scientific Manuscript database
Four Roller pigeons (Columba livia f. dom.) at the Philadelphia Zoo died suddenly. Necropsy examination revealed macroscopic hepatitis. Microscopically, the predominant lesions were in liver, characterized with necrosis and mixed cell inflammatory response. Sarcocystis calchasi-like schizonts and fr...
Almutlak, Mohammed A; Aloniazan, Turki; May, William
2017-01-01
A 55-year-old male presented with reduced vision due to senile cataract. The patient consented to undergo real-time intraoperative anterior segment-optical coherence tomography (AS-OCT) during phacoemulsification with intraocular lens (IOL) implantation. Images were captured at various points during the surgery. The use of AS-OCT incorporated into the surgical microscope was evaluated as an adjunct to cataract surgery. We were able to successfully evaluate, in real-time, wound architecture, the attachment of Descemet's membrane, the posterior capsule, and IOL position. Real-time AS-OCT can be used to proactively address potential complications and verify IOL placement intraoperatively.
Watching fat digestion: a microscopic method assessing intraluminal lipolysis.
Alliet, P; Eggermont, E
1990-01-01
We investigated the utility of a microscopic method assessing lipolytic activity of duodenal fluid. The method is based on evaluating microscopically physicochemical changes along time when olive oil is mixed with duodenal fluid in the presence of excess bile salts (13 mM) and calcium ions (8 mM) at pH 6.5. Data are analyzed on duodenal aspirations from 155 children referred for failure to thrive or gastrointestinal disorders. The "fat digestion index" (FDI) is the percentage of intact olive oil droplets that underwent complete hydrolysis or are transformed into amorphous reticular bodies (ARB) at steady state. In all patients with proven exocrine pancreatic disorder, a FDI less than 25% was found. This value was thus considered as a cut-off value. When no microscopic lipolysis (FDI = 0) was observed, exocrine pancreatic enzyme assays are suggestive for a total exocrine pancreatic insufficiency. In the group of children with FDI ranging 5-25%, however, no statistical difference in exocrine pancreatic enzymes could be found, as compared to control values. Our tests thus evaluate fat digestion in a dynamic way. It further seems to give additional information on intraluminal lipolysis as compared to exocrine pancreatic enzyme concentrations, since it gives an idea about the integrated action of (co)lipase and bile salts.
Clinical use of a portable dual microscope system for smartphone (Conference Presentation)
NASA Astrophysics Data System (ADS)
Kurachi, Cristina; Brognara, Gabriel; Gómez-García, Pablo A.; Carbinatto, Fernanda; Silva, Eduardo V.; Lombardi, Wellington; Inada, Natália M.; Bagnato, Vanderlei S.
2016-03-01
Cervical cancer is still one of the most relevant women cancer types, since the 5-year survival rate is of only around 68%. Prevention and early diagnosis are the best strategies to improve cervical cancer prognosis. Conventional diagnosis procedure in Gynecology is mainly based on the macroscopic clinical evaluation, Pap smear cytology, and biopsy, if needed. A portable microscope with dual configuration and its use for diagnosis in Gynecology is investigated. The microscope has interchangeable parts that allow its use for cytopathology smear samples or in situ endoscopic tissue interrogation, both using acriflavine as a nuclei marker. Patients of the Women Ambulatory of the School of Medicine (UNIARA, Araraquara, Brazil) were interrogated during the colposcopy examination. The cervix was initially cleaned using an acetic acid solution, and a 0.05% (wt/vol) acriflavine in saline solution was topically applied at the tissue surface using a cotton swab. Microendoscopy images were taken from clinically normal cervix mucosa and from detected lesions. An image processing is performed to evaluate the cell nuclei morphology and the cytoplasm/nuclei ratio. The Pap smear results and the histology analyses are taken as gold standard for the diagnosis. Preliminary results in 5 patients demonstrated the potential use of our microscope at the clinical setting.
The Impact of the Condenser on Cytogenetic Image Quality in Digital Microscope System
Ren, Liqiang; Li, Zheng; Li, Yuhua; Zheng, Bin; Li, Shibo; Chen, Xiaodong; Liu, Hong
2013-01-01
Background: Optimizing operational parameters of the digital microscope system is an important technique to acquire high quality cytogenetic images and facilitate the process of karyotyping so that the efficiency and accuracy of diagnosis can be improved. OBJECTIVE: This study investigated the impact of the condenser on cytogenetic image quality and system working performance using a prototype digital microscope image scanning system. Methods: Both theoretical analysis and experimental validations through objectively evaluating a resolution test chart and subjectively observing large numbers of specimen were conducted. Results: The results show that the optimal image quality and large depth of field (DOF) are simultaneously obtained when the numerical aperture of condenser is set as 60%–70% of the corresponding objective. Under this condition, more analyzable chromosomes and diagnostic information are obtained. As a result, the system shows higher working stability and less restriction for the implementation of algorithms such as autofocusing especially when the system is designed to achieve high throughput continuous image scanning. Conclusions: Although the above quantitative results were obtained using a specific prototype system under the experimental conditions reported in this paper, the presented evaluation methodologies can provide valuable guidelines for optimizing operational parameters in cytogenetic imaging using the high throughput continuous scanning microscopes in clinical practice. PMID:23676284
Gorler, Oguzhan; Saygin, Aysegul Goze
2017-06-01
Laser modalities and direct metal laser sintering (DMLS) have a potential to enhance micromechanical bonding between dental super- and infrastructures. However, the effect of different manufacturing methods on the metal-ceramic bond strength needs further evaluation. We investigated the effect of surface treatment with Er:YAG, Nd:YAG, and Ho:YAG lasers on the shear bond strength (SBS) of high-fusion dental porcelains (Vita and G-Ceram) to infrastructures prepared with DMLS in vitro settings. Study specimens (n = 128) were randomly divided into study subsets (n = 8), considering treatment types applied on the surface of infrastructures, including sandblasting and selected laser modalities; infrastructure types as direct laser sintered (DLS) and Ni-Cr based; and superstructure porcelains as Vita and G-Ceram. The SBS test was performed to assess the effectiveness of surface modifications that were also examined with a stereo microscope. Considering laser procedure types, the highest SBS values were obtained by Er:YAG laser, followed by, with a decreasing efficiency, Ho:YAG laser and sandblasting procedures, and Nd:YAG laser procedure (p < 0.05). Nd:YAG laser decreases the bonding of Vita and G-Ceram in all the infrastructures compared with sandblasting. Considering porcelains, the highest SBS values were obtained by Vita (p < 0.05). Considering infrastructures, the highest SBS values were obtained by DMLS procedure (p < 0.05). The laser procedures caused surface irregularities as revealed by the stereo microscopic examination. In current experimental settings, Er:YAG laser applied to DLS infrastructure veneered with Vita porcelain increases bonding strength more distinctly, and Nd:YAG laser applied to Ni-Cr-based infrastructure veneered with G-Ceram porcelain alters bonding strength unfavorably.
Dabaghian, Farid; Khademian, Sedigheh; Azadi, Amir; Zarshenas, Mohammad
2016-05-01
As the most common form of dementia, Alzheimer disease is characterized by progressive loss of memory and deterioration of cognitive functions. It is predicted that about 75.63 million people would suffer from dementia by 2030. Apart from conventional remedies, the application of herbal medicines is on the rise. There are numerous natural medicaments reported in the traditional manuscript of Persian medicine. Accordingly, in the present study, the intended remedy was selected and an appropriate pharmacognostical and pharmaceutical evaluations were performed. By searching through the traditional pharmaceutical manuscripts such as Qarabadeen-e-Salehi, Qarabadeen-e-Azam, Qarabadeen-e-Ghaderi and Canon of Medicine, a simple but proven compound remedy (frankincense and black pepper) was selected. A floating tablet was designed and formulated from those herbal components. Related pharmaceutical assessments such as weight variation, hardness, friability, and disintegration tests as well as pharmacognostical evaluations such as microscopic characterization, TLC, GC/MS, FT/IR fingerprints, and radical scavenging activity assessment (DPPH) were performed. The resulting formulation, as a floating tablet, included 60% of frankincense gum and 15% of black pepper along with appropriate pharmaceutical ingredients (weight variation: 0.219±0.004 g, hardness: 6.50±0.67, friability: 0.45%, disintegration time >30 min). Microscopic characterization demonstrated stone cells, calcium oxalate crystals, sclereids of endocarp and pitted cells of mesocarp of pepper fruits as well as oil drops of frankincense gum. TLC fingerprinting showed classes of secondary metabolites related to both components. GC/MS analysis revealed Acetyl acetate and trans-Caryophyllene as the main constituent. Moderate radical scavenging activity (IC50 >100 µg/ml) was calculated for the methanol extract of tablets. Carrying out and validating a GC method for standardization of the formulated tablet, and having the structure for the effectiveness of these medicinal herbs in Alzheimer may be the horizon for a new Alzheimer-targeted medicine.
Dabaghian, Farid; Khademian, Sedigheh; Azadi, Amir; Zarshenas, Mohammad
2016-05-01
As the most common form of dementia, Alzheimer disease is characterized by progressive loss of memory and deterioration of cognitive functions. It is predicted that about 75.63 million people would suffer from dementia by 2030. Apart from conventional remedies, the application of herbal medicines is on the rise. There are numerous natural medicaments reported in the traditional manuscript of Persian medicine. Accordingly, in the present study, the intended remedy was selected and an appropriate pharmacognostical and pharmaceutical evaluations were performed. By searching through the traditional pharmaceutical manuscripts such as Qarabadeen-e-Salehi, Qarabadeen-e-Azam, Qarabadeen-e-Ghaderi and Canon of Medicine, a simple but proven compound remedy (frankincense and black pepper) was selected. A floating tablet was designed and formulated from those herbal components. Related pharmaceutical assessments such as weight variation, hardness, friability, and disintegration tests as well as pharmacognostical evaluations such as microscopic characterization, TLC, GC/MS, FT/IR fingerprints, and radical scavenging activity assessment (DPPH) were performed. The resulting formulation, as a floating tablet, included 60% of frankincense gum and 15% of black pepper along with appropriate pharmaceutical ingredients (weight variation: 0.219±0.004 g, hardness: 6.50±0.67, friability: 0.45%, disintegration time >30 min). Microscopic characterization demonstrated stone cells, calcium oxalate crystals, sclereids of endocarp and pitted cells of mesocarp of pepper fruits as well as oil drops of frankincense gum. TLC fingerprinting showed classes of secondary metabolites related to both components. GC/MS analysis revealed Acetyl acetate and trans-Caryophyllene as the main constituent. Moderate radical scavenging activity (IC 50 >100 µg/ml) was calculated for the methanol extract of tablets. Carrying out and validating a GC method for standardization of the formulated tablet, and having the structure for the effectiveness of these medicinal herbs in Alzheimer may be the horizon for a new Alzheimer-targeted medicine.
Size determination of Acipenser ruthenus spermatozoa in different types of electron microscopy.
Psenicka, Martin; Tesarová, Martina; Tesitel, Jakub; Nebesárová, Jana
2010-07-01
In this study three types of scanning electron microscopes were used for the size determination of spermatozoa of sterlet Acipenser ruthenus - high vacuum scanning electron microscope (SEM, JEOL 6300), environmental scanning electron microscope (ESEM, Quanta 200 FEG), field emission scanning electron microscope (FESEM, JEOL 7401F) with cryoattachment Alto 2500 (Gatan) and transmission electron microscope (TEM, JEOL 1010). The use of particular microscopes was tied with different specimen preparation techniques. The aim of this study was to evaluate to what degree the type of used electron microscope can influence the size of different parts of spermatozoa. For high vacuum SEM the specimen was prepared using two slightly different procedures. After chemical fixation with 2.5% glutaraldehyde in 0.1M phosphate buffer and post-fixation by 1% osmium tetroxide, the specimen was dehydrated by acetone series and dried either by critical point method or by means of t-butylalcohol. For ESEM fresh, unfixed material was used, which was dropped on microscopic copper grids. In FESEM working in cryo-mode the specimen was observed in a frozen state. Ultrathin sections from chemically fixed and Epon embedded specimens were prepared for TEM observation. Distinct parts of sterlet spermatozoa were measured in each microscope and the data obtained was statistically processed. Results confirmed that the classical chemical procedure of specimen preparation for SEM including critical point drying method led to a significant contraction of all measured values, which could deviate up to 30% in comparison with values measured on the fresh chemically untreated specimen in ESEM. Surprisingly sperm dimensions determinated on ultrathin sections by TEM are comparable with values obtained in ESEM or FESEM. Copyright 2010 Elsevier Ltd. All rights reserved.
B2 Grain Growth Behavior of a Ti-22Al-25Nb Alloy Fabricated by Hot Pressing Sintering
NASA Astrophysics Data System (ADS)
Jia, Jianbo; Liu, Wenchao; Xu, Yan; Chen, Chen; Yang, Yue; Luo, Junting; Zhang, Kaifeng
2018-05-01
Grain growth behavior of a powder metallurgy (P/M) Ti-22Al-25Nb alloy was investigated by applying a series of isothermal treatment tests over a wide range of temperatures and holding times. An isothermal treatment scheme was conducted in the B2 phase region (1070-1110 °C) and α 2 + B2 phase region (1010-1050 °C) at holding times of 10, 30 min, 1, 2, and 3 h, respectively. The effects of temperature and holding time on the microstructure evolution and microhardness of the P/M Ti-22Al-25Nb alloy at elevated temperatures were evaluated using optical microscope, scanning electron microscope, x-ray diffraction, and Vickers hardness test techniques. The results revealed that the alloy's treated microstructure was closely linked to temperature and holding time, respectively. The change law of B2 grain growth with holding time and temperature can be well interpreted by the Beck equation and Hillert equation, respectively. The B2 grain growth exponent n and activation energy Q were acquired based on experimental data in the α 2 + B2 and B2 phase regions. In addition, the grain growth contour map for the P/M Ti-22Al-25Nb alloy was constructed to depict variations in B2 grain size based on holding time and temperature.
Abeytunge, Sanjee; Larson, Bjorg; Peterson, Gary; Morrow, Monica; Rajadhyaksha, Milind
2017-01-01
Abstract. Confocal microscopy is an emerging technology for rapid imaging of freshly excised tissue without the need for frozen- or fixed-section processing. Initial studies have described imaging of breast tissue using fluorescence confocal microscopy with small regions of interest, typically 750×750 μm2. We present exploration with a microscope, termed confocal strip-mosaicking microscope (CSM microscope), which images an area of 2×2 cm2 of tissue with cellular-level resolution in 10 min of excision. Using the CSM microscope, we imaged 34 fresh, human, large breast tissue specimens from 18 patients, blindly analyzed by a board-certified pathologist and subsequently correlated with the corresponding standard fixed histopathology. Invasive tumors and benign tissue were clearly identified in CSM strip-mosaic images. Thirty specimens were concordant for image-to-histopathology correlation while four were discordant. PMID:28327961
High-Temperature Shape Memory Alloys
NASA Astrophysics Data System (ADS)
Biffi, C. A.; Tuissi, A.
2014-10-01
In this paper, an experimental study of laser micro-processing on a Cu-Zr-based shape memory alloy (SMA), which is suitable for high-temperature (HT) applications, is discussed. A first evaluation of the interaction between a laser beam and Zr50Cu28Ni7Co15 HT SMA is highlighted. Single laser pulses at various levels of power and pulse duration were applied to evaluate their effect on the sample surfaces. Blind and through microholes were produced with sizes on the order of a few hundreds of microns; the results were characterized from the morphological viewpoint using a scanning electron microscope. The high beam quality allows the holes to be created with good circularity and little melted material around the hole periphery. An analysis of the chemical composition was performed using energy dispersive spectroscopy, revealing that compositional changes were limited, while important oxidation occurred on the hole surfaces. Additionally, laser micro-cutting tests were also proposed to evaluate the cut edge morphology and dimensions. The main result of this paper concerned the good behavior of the material upon interaction with the laser beam, which suggests that microfeatures can be successfully produced in this alloy.
NASA Astrophysics Data System (ADS)
Wang, Bohan; Wang, Hsing-Wen; Guo, Hengchang; Anderson, Erik; Tang, Qinggong; Wu, Tongtong; Falola, Reuben; Smith, Tikina; Andrews, Peter M.; Chen, Yu
2017-12-01
Chronic kidney disease (CKD) is characterized by a progressive loss of renal function over time. Histopathological analysis of the condition of glomeruli and the proximal convolutional tubules over time can provide valuable insights into the progression of CKD. Optical coherence tomography (OCT) is a technology that can analyze the microscopic structures of a kidney in a nondestructive manner. Recently, we have shown that OCT can provide real-time imaging of kidney microstructures in vivo without administering exogenous contrast agents. A murine model of CKD induced by intravenous Adriamycin (ADR) injection is evaluated by OCT. OCT images of the rat kidneys have been captured every week up to eight weeks. Tubular diameter and hypertrophic tubule population of the kidneys at multiple time points after ADR injection have been evaluated through a fully automated computer-vision system. Results revealed that mean tubular diameter and hypertrophic tubule population increase with time in post-ADR injection period. The results suggest that OCT images of the kidney contain abundant information about kidney histopathology. Fully automated computer-aided diagnosis based on OCT has the potential for clinical evaluation of CKD conditions.
NASA Astrophysics Data System (ADS)
Capote, R.; Herman, M.; Obložinský, P.; Young, P. G.; Goriely, S.; Belgya, T.; Ignatyuk, A. V.; Koning, A. J.; Hilaire, S.; Plujko, V. A.; Avrigeanu, M.; Bersillon, O.; Chadwick, M. B.; Fukahori, T.; Ge, Zhigang; Han, Yinlu; Kailas, S.; Kopecky, J.; Maslov, V. M.; Reffo, G.; Sin, M.; Soukhovitskii, E. Sh.; Talou, P.
2009-12-01
We describe the physics and data included in the Reference Input Parameter Library, which is devoted to input parameters needed in calculations of nuclear reactions and nuclear data evaluations. Advanced modelling codes require substantial numerical input, therefore the International Atomic Energy Agency (IAEA) has worked extensively since 1993 on a library of validated nuclear-model input parameters, referred to as the Reference Input Parameter Library (RIPL). A final RIPL coordinated research project (RIPL-3) was brought to a successful conclusion in December 2008, after 15 years of challenging work carried out through three consecutive IAEA projects. The RIPL-3 library was released in January 2009, and is available on the Web through http://www-nds.iaea.org/RIPL-3/. This work and the resulting database are extremely important to theoreticians involved in the development and use of nuclear reaction modelling (ALICE, EMPIRE, GNASH, UNF, TALYS) both for theoretical research and nuclear data evaluations. The numerical data and computer codes included in RIPL-3 are arranged in seven segments: MASSES contains ground-state properties of nuclei for about 9000 nuclei, including three theoretical predictions of masses and the evaluated experimental masses of Audi et al. (2003). DISCRETE LEVELS contains 117 datasets (one for each element) with all known level schemes, electromagnetic and γ-ray decay probabilities available from ENSDF in October 2007. NEUTRON RESONANCES contains average resonance parameters prepared on the basis of the evaluations performed by Ignatyuk and Mughabghab. OPTICAL MODEL contains 495 sets of phenomenological optical model parameters defined in a wide energy range. When there are insufficient experimental data, the evaluator has to resort to either global parameterizations or microscopic approaches. Radial density distributions to be used as input for microscopic calculations are stored in the MASSES segment. LEVEL DENSITIES contains phenomenological parameterizations based on the modified Fermi gas and superfluid models and microscopic calculations which are based on a realistic microscopic single-particle level scheme. Partial level densities formulae are also recommended. All tabulated total level densities are consistent with both the recommended average neutron resonance parameters and discrete levels. GAMMA contains parameters that quantify giant resonances, experimental gamma-ray strength functions and methods for calculating gamma emission in statistical model codes. The experimental GDR parameters are represented by Lorentzian fits to the photo-absorption cross sections for 102 nuclides ranging from 51V to 239Pu. FISSION includes global prescriptions for fission barriers and nuclear level densities at fission saddle points based on microscopic HFB calculations constrained by experimental fission cross sections.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Capote, R.; Herman, M.; Oblozinsky, P.
We describe the physics and data included in the Reference Input Parameter Library, which is devoted to input parameters needed in calculations of nuclear reactions and nuclear data evaluations. Advanced modelling codes require substantial numerical input, therefore the International Atomic Energy Agency (IAEA) has worked extensively since 1993 on a library of validated nuclear-model input parameters, referred to as the Reference Input Parameter Library (RIPL). A final RIPL coordinated research project (RIPL-3) was brought to a successful conclusion in December 2008, after 15 years of challenging work carried out through three consecutive IAEA projects. The RIPL-3 library was released inmore » January 2009, and is available on the Web through (http://www-nds.iaea.org/RIPL-3/). This work and the resulting database are extremely important to theoreticians involved in the development and use of nuclear reaction modelling (ALICE, EMPIRE, GNASH, UNF, TALYS) both for theoretical research and nuclear data evaluations. The numerical data and computer codes included in RIPL-3 are arranged in seven segments: MASSES contains ground-state properties of nuclei for about 9000 nuclei, including three theoretical predictions of masses and the evaluated experimental masses of Audi et al. (2003). DISCRETE LEVELS contains 117 datasets (one for each element) with all known level schemes, electromagnetic and {gamma}-ray decay probabilities available from ENSDF in October 2007. NEUTRON RESONANCES contains average resonance parameters prepared on the basis of the evaluations performed by Ignatyuk and Mughabghab. OPTICAL MODEL contains 495 sets of phenomenological optical model parameters defined in a wide energy range. When there are insufficient experimental data, the evaluator has to resort to either global parameterizations or microscopic approaches. Radial density distributions to be used as input for microscopic calculations are stored in the MASSES segment. LEVEL DENSITIES contains phenomenological parameterizations based on the modified Fermi gas and superfluid models and microscopic calculations which are based on a realistic microscopic single-particle level scheme. Partial level densities formulae are also recommended. All tabulated total level densities are consistent with both the recommended average neutron resonance parameters and discrete levels. GAMMA contains parameters that quantify giant resonances, experimental gamma-ray strength functions and methods for calculating gamma emission in statistical model codes. The experimental GDR parameters are represented by Lorentzian fits to the photo-absorption cross sections for 102 nuclides ranging from {sup 51}V to {sup 239}Pu. FISSION includes global prescriptions for fission barriers and nuclear level densities at fission saddle points based on microscopic HFB calculations constrained by experimental fission cross sections.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Capote, R.; Herman, M.; Capote,R.
We describe the physics and data included in the Reference Input Parameter Library, which is devoted to input parameters needed in calculations of nuclear reactions and nuclear data evaluations. Advanced modelling codes require substantial numerical input, therefore the International Atomic Energy Agency (IAEA) has worked extensively since 1993 on a library of validated nuclear-model input parameters, referred to as the Reference Input Parameter Library (RIPL). A final RIPL coordinated research project (RIPL-3) was brought to a successful conclusion in December 2008, after 15 years of challenging work carried out through three consecutive IAEA projects. The RIPL-3 library was released inmore » January 2009, and is available on the Web through http://www-nds.iaea.org/RIPL-3/. This work and the resulting database are extremely important to theoreticians involved in the development and use of nuclear reaction modelling (ALICE, EMPIRE, GNASH, UNF, TALYS) both for theoretical research and nuclear data evaluations. The numerical data and computer codes included in RIPL-3 are arranged in seven segments: MASSES contains ground-state properties of nuclei for about 9000 nuclei, including three theoretical predictions of masses and the evaluated experimental masses of Audi et al. (2003). DISCRETE LEVELS contains 117 datasets (one for each element) with all known level schemes, electromagnetic and {gamma}-ray decay probabilities available from ENSDF in October 2007. NEUTRON RESONANCES contains average resonance parameters prepared on the basis of the evaluations performed by Ignatyuk and Mughabghab. OPTICAL MODEL contains 495 sets of phenomenological optical model parameters defined in a wide energy range. When there are insufficient experimental data, the evaluator has to resort to either global parameterizations or microscopic approaches. Radial density distributions to be used as input for microscopic calculations are stored in the MASSES segment. LEVEL DENSITIES contains phenomenological parameterizations based on the modified Fermi gas and superfluid models and microscopic calculations which are based on a realistic microscopic single-particle level scheme. Partial level densities formulae are also recommended. All tabulated total level densities are consistent with both the recommended average neutron resonance parameters and discrete levels. GAMMA contains parameters that quantify giant resonances, experimental gamma-ray strength functions and methods for calculating gamma emission in statistical model codes. The experimental GDR parameters are represented by Lorentzian fits to the photo-absorption cross sections for 102 nuclides ranging from {sup 51}V to {sup 239}Pu. FISSION includes global prescriptions for fission barriers and nuclear level densities at fission saddle points based on microscopic HFB calculations constrained by experimental fission cross sections.« less
Protein immobilization onto electrochemically synthesized CoFe nanowires
Torati, Sri Ramulu; Reddy, Venu; Yoon, Seok Soo; Kim, CheolGi
2015-01-01
CoFe nanowires have been synthesized by the electrodeposition technique into the pores of a polycarbonate membrane with a nominal pore diameter of 50 nm, and the composition of CoFe nanowires varying by changing the source concentration of iron. The synthesized nanowire surfaces were functionalized with amine groups by treatment with aminopropyltriethoxysilane (APTES) linker, and then conjugated with streptavidin-Cy3 protein via ethyl (dimethylaminopropyl) carbodiimide and N-hydroxysuccinimide coupling chemistry. The oxide surface of CoFe nanowire is easily modified with aminopropyltriethoxysilane to form an amine terminating group, which is covalently bonded to streptavidin-Cy3 protein. The physicochemical properties of the nanowires were analyzed through different characterization techniques such as scanning electron microscope, energy dispersive spectroscopy, and vibrating sample magnetometer. Fluorescence microscopic studies and Fourier transform infrared studies confirmed the immobilization of protein on the nanowire surface. In addition, the transmission electron microscope analysis reveals the thin protein layer which is around 12–15 nm on the nanowire surfaces. PMID:25609966
Faria, Luiz F O; Paschoal, Vitor H; Lima, Thamires A; Ferreira, Fabio F; Freitas, Rafael S; Ribeiro, Mauro C C
2017-10-26
A local order-disorder transition has been disclosed in the thermophysical behavior of the ionic liquid 1-benzyl-3-methylimidazolium dicyanamide, [Bzmim][N(CN) 2 ], and its microscopic nature revealed by spectroscopic techniques. Differential scanning calorimetry and specific heat measurements show a thermal event of small enthalpy variation taking place in the range 250-260 K, which is not due to crystallization or melting. Molecular dynamic simulations and X-ray diffraction measurements have been used to discuss the segregation of domains in the liquid structure of [Bzmim][N(CN) 2 ]. Raman and NMR spectroscopy measurements as a function of temperature indicate that the microscopic origin of the event observed in the calorimetric measurements comes from structural rearrangement involving the benzyl group. The results indicate that the characteristic structural heterogeneity allow for rearrangements within local domains implying the good glass-forming ability for the low viscosity ionic liquid [Bzmim][N(CN) 2 ]. This work sheds light on our understanding of the microscopic origin behind complex thermal behavior of ionic liquids.
Unravelling the secret of seed-based gels in water: the nanoscale 3D network formation.
Samateh, Malick; Pottackal, Neethu; Manafirasi, Setareh; Vidyasagar, Adiyala; Maldarelli, Charles; John, George
2018-05-09
Chia (Salvia hispanica) and basil (Ocimum basilicum) seeds have the intrinsic ability to form a hydrogel concomitant with moisture-retention, slow releasing capability and proposed health benefits such as curbing diabetes and obesity by delaying digestion process. However, the underlying mode of gelation at nanoscopic level is not clearly explained or explored. The present study elucidates and corroborates the hypothesis that the gelling behavior of such seeds is due to their nanoscale 3D-network formation. The preliminary study revealed the influence of several conditions like polarity, pH and hydrophilicity/hydrophobicity on fiber extrusion from the seeds which leads to gelation. Optical microscopic analysis clearly demonstrated bundles of fibers emanating from the seed coat while in contact with water, and live growth of fibers to form 3D network. Scanning electron microscope (SEM) and transmission electron microscope (TEM) studies confirmed 3D network formation with fiber diameters ranging from 20 to 50 nm.
Dynamic Contact Angle at the Nanoscale: A Unified View.
Lukyanov, Alex V; Likhtman, Alexei E
2016-06-28
Generation of a dynamic contact angle in the course of wetting is a fundamental phenomenon of nature. Dynamic wetting processes have a direct impact on flows at the nanoscale, and therefore, understanding them is exceptionally important to emerging technologies. Here, we reveal the microscopic mechanism of dynamic contact angle generation. It has been demonstrated using large-scale molecular dynamics simulations of bead-spring model fluids that the main cause of local contact angle variations is the distribution of microscopic force acting at the contact line region. We were able to retrieve this elusive force with high accuracy. It has been directly established that the force distribution can be solely predicted on the basis of a general friction law for liquid flow at solid surfaces by Thompson and Troian. The relationship with the friction law provides both an explanation of the phenomenon of dynamic contact angle and a methodology for future predictions. The mechanism is intrinsically microscopic, universal, and irreducible and is applicable to a wide range of problems associated with wetting phenomena.
Venâncio, Daniel P.; Andersen, Monica L.; Vilamaior, Patricia S. L.; Santos, Fernanda C.; Zager, Adriano; Tufik, Sérgio; Taboga, Sebastião R.; De Mello, Marco T.
2012-01-01
We investigated the effect of 96 h paradoxical sleep deprivation (PSD) and 21-day sleep restriction (SR) on prostate morphology using stereological assays in male rats. After euthanasia, the rat ventral prostate was removed, weighed, and prepared for conventional light microscopy. Microscopic analysis of the prostate reveals that morphology of this gland was altered after 96 h of PSD and 21 days of SR, with the most important alterations occurring in the epithelium and stroma in the course of both procedures compared with the control group. Both 96 h PSD and 21-day SR rats showed lower serum testosterone and higher corticosterone levels than control rats. The significance of our result referring to the sleep deprivation was responsible for deep morphological alterations in ventral prostate tissue, like to castration microscopic modifications. This result is due to the marked alterations in hormonal status caused by PSD and SR. PMID:22927719
NASA Astrophysics Data System (ADS)
Nagazi, Med-Yassine; Brambilla, Giovanni; Meunier, Gérard; Marguerès, Philippe; Périé, Jean-Noël; Cipelletti, Luca
2017-01-01
We couple a laser-based, space-resolved dynamic light scattering apparatus to a universal traction machine for mechanical extensional tests. We perform simultaneous optical and mechanical measurements on polyether ether ketone, a semi-crystalline polymer widely used in the industry. Due to the high turbidity of the sample, light is multiply scattered by the sample and the diffusing wave spectroscopy (DWS) formalism is used to interpret the data. Space-resolved DWS yields spatial maps of the sample strain and of the microscopic dynamics. An excellent agreement is found between the strain maps thus obtained and those measured by a conventional stereo-digital image correlation technique. The microscopic dynamics reveals both affine motion and plastic rearrangements. Thanks to the extreme sensitivity of DWS to displacements as small as 1 nm, plastic activity and its spatial localization can be detected at an early stage of the sample strain, making the technique presented here a valuable complement to existing material characterization methods.
NASA Astrophysics Data System (ADS)
Zahoor, Ahmad; Teng, Qiu; Wang, Haiqiao; Choudhry, M. A.; Li, Xiaoyu
2011-06-01
Ag@polycarbazole coaxial nanocables (CNCs) have been successfully fabricated by the oxidative polymerization of carbazole over Ag nanowires (NWs) in acetonitrile. The morphology of Ag NWs and CNCs was studied by employing a transmission electron microscope (TEM) and a scanning electron microscope (SEM), which showed them to be a monodisperse material. The thickness of the polymer sheath was found to be 5 nm to 8 nm by observation under a high-resolution transmission electron microscope (HR-TEM). Energy dispersive X-ray spectroscopy (EDS), FT-IR and Raman measurements were used to characterize the polymer sheath, which demonstrated it to be a carbon material in polycarbazole form. X-ray photoelectron spectroscopy (XPS) was used for an interfacial study, which revealed that Ag surface atoms remained intact during polymer growth. In the end, zeta potential showed that the dispersion stability of Ag NWs increased due to polymer encapsulation, which is significant to obtain a particular alignment for anisotropic measurement of electrical conductivity.
Tatlisumak, Ertugrul; Inan, Sevinc; Asirdizer, Mahmut; Apaydin, Nihal; Hayretdag, Ceyda; Kose, Can; Tekdemir, Ibrahim
2009-03-01
Approximately 10% of all deaths in the world occur as a result of stroke. Determination of the time schedule of the pathologic events in a stroke patient is invaluable for a forensic specialist. The aim of this study was to define the schedule of the macroscopic and microscopic changes that occurred in a rat model of permanent focal ischemia for providing useful clues for the evaluation of stroke patients. Male Wistar rats weighing 250 to 350 g were used in this study. Permanent focal brain ischemia was applied by the suture occlusion method. The animals were divided into 7 experimental groups (n = 6) with time schedules including 1.5, 3, 6, 12, 24, 72 hours, and the sham. Brains were harvested at the end of the determined time schedule. Lesions in the frontoparietal cortex were evaluated macroscopically first and later hematoxylin eosin stained sections from the infarct core were investigated microscopically. Macroscopically, enlargement of the ipsilateral hemisphere was mild at 6 hour, apparent at 12 and 24 hours, and mild again at 72 hours. Microscopically, ischemic changes were apparent even at 1.5 hour. Red neurons and infiltration of the parenchyma with neutrophil leukocytes were observed at 12 hours. Pannecrosis and massive leukocyte infiltration were observed at 72 hours. Macroscopic and microscopic findings obtained from a rat model may provide clues for determination of the time-dependent changes due to brain ischemia in human subjects. Finally, the benefits of determination of time course of pathologic changes in the brain for forensic scientists were discussed.
Ladd, Bryan M; Tackla, Ryan D; Gupte, Akshay; Darrow, David; Sorenson, Jeffery; Zuccarello, Mario; Grande, Andrew W
2017-03-01
Our pilot study evaluated the effectiveness of our telementoring-telescripting model to facilitate seamless communication between surgeons while the operating surgeon is using a microscope. As a first proof of concept, 4 students identified 20 anatomic landmarks on a dry human skull with or without telementoring guidance. To assess the ability to communicate operative information, a senior neurosurgery resident evaluated the student's ability and timing to complete a stepwise craniotomy on a cadaveric head, with and without telementoring guidance; a second portion included exposure of the anterior circulation. The mentor was able to annotate directly onto the operator's visual field, which was visible to the operator without looking away from the binocular view. The students showed that they were familiar with half (50% ± 10%) of the structures for identification and none was familiar with the steps to complete a craniotomy before using our system. With the guidance of a remote surgeon projected into the visual field of the microscope, the students were able to correctly identify 100% of the structures and complete a craniotomy. Our system also proved effective in guiding a more experienced neurosurgery resident through complex operative steps associated with exposure of the anterior circulation. Our pilot study showed a platform feasible in providing effective operative direction to inexperienced operators while operating using a microscope. A remote mentor was able to view the visual field of the microscope, annotate on the visual stream, and have the annotated stream appear in the binocular view for the operating mentee. Copyright © 2016 Elsevier Inc. All rights reserved.
Elliott, Jonathan T; Dsouza, Alisha V; Marra, Kayla; Pogue, Brian W; Roberts, David W; Paulsen, Keith D
2016-09-01
Fluorescence guided surgery has the potential to positively impact surgical oncology; current operating microscopes and stand-alone imaging systems are too insensitive or too cumbersome to maximally take advantage of new tumor-specific agents developed through the microdose pathway. To this end, a custom-built illumination and imaging module enabling picomolar-sensitive near-infrared fluorescence imaging on a commercial operating microscope is described. The limits of detection and system specifications are characterized, and in vivo efficacy of the system in detecting ABY-029 is evaluated in a rat orthotopic glioma model following microdose injections, showing the suitability of the device for microdose phase 0 clinical trials.
Dsouza, Alisha V.; Marra, Kayla; Pogue, Brian W.; Roberts, David W.; Paulsen, Keith D.
2016-01-01
Fluorescence guided surgery has the potential to positively impact surgical oncology; current operating microscopes and stand-alone imaging systems are too insensitive or too cumbersome to maximally take advantage of new tumor-specific agents developed through the microdose pathway. To this end, a custom-built illumination and imaging module enabling picomolar-sensitive near-infrared fluorescence imaging on a commercial operating microscope is described. The limits of detection and system specifications are characterized, and in vivo efficacy of the system in detecting ABY-029 is evaluated in a rat orthotopic glioma model following microdose injections, showing the suitability of the device for microdose phase 0 clinical trials. PMID:27699098
Seo, Hyejin; Nam, Dong Heun; Lee, Jong Yeon; Park, Su Jin; Kim, Yu Jeong; Kim, Seong-Woo; Chung, Tae-Young; Inoue, Makoto; Kim, Terry
2018-02-01
To evaluate macular photostress and visual experience between coaxial microscope illumination versus oblique intracameral illumination during cataract surgery. Gachon University Gil Hospital, Incheon, South Korea. Prospective case series. Consecutive patients who had cataract surgery using microscope illumination and intracameral illumination were included. The patients were asked to complete a questionnaire (seeing strong lights, feeling photophobia, feeling startled (fright) when seeing lights, seeing any colors, seeing any instruments or surgical procedures, and estimating intraoperative visual function) designed to describe their cataract surgery experience. The images projected on the retina of the model eye (rear view) with artificial opaque fragments in the anterior chamber during simulating cataract surgery were compared between the 2 illumination types. Sixty patients completed the questionnaire. Scores for strong lights, photophobia, fright, and color perception were significantly higher with microscope illumination than with intracameral illumination (all P < .001). More patients preferred the intracameral illumination (45 [75.0%]) to the microscope illumination (13 [21.7%]). In the rear-view images created in a model eye, only the bright microscope light in the center was seen without any lens image in the microscope illumination. However, in the intracameral illumination, the less bright light from the light pipe in the periphery and the lens fragments were seen more clearly. In a view of the patients' visual experience, oblique intracameral illumination caused less subjective photostress and was preferred over coaxial microscope illumination. Objective findings from the model-eye experiment correlated to the result of visual experience. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Imaia, a new truffle genus to accommodate TerJezia gigantea
Gabor M. Kovacs; James M. Trappe; Abulmagid Alsheikh; Karoly Boka
2008-01-01
Originally described from Japan by Sanshi Imai in 1933, the hypogeous ascomycete Terjezia gigantea was subsequently discovered in the Appalachian Mountains of the USA. Morphological, electron microscopic, and phylogenetic studies of specimens collected in both regions revealed that, despite this huge geographic disjunction, (1) the Japanese and...
career at NREL in 1995 by conducting scanning tunneling microscope (STM) studies of the atomic structure revealed a new strain-induced step structure and contributed to the development of world-record-efficiency NREL's Computational Materials Science team, probing the atomic structure of dislocations in III-V
Scanning Probe Platform | Materials Science | NREL
level; this image obtained using a scanning tunneling microscope shows gray and white clusters of produce high-resolution color images or maps like this one obtained using scanning tunneling luminescence gray clusters. Gold substrate: (Left) STM image reveals the terraces of the H2 flamed substrate. (Right
Shayani Rad, Maryam; Khameneh, Bahman; Sabeti, Zahra; Mohajeri, Seyed Ahmad; Fazly Bazzaz, Bibi Sedigheh
2016-10-01
In the present work, the effect of monomer composition on silver nanoparticles' (SNPs) binding capacity of hydrogels was investigated and their antibacterial efficacy was evaluated. Three series of poly-hydroxyethyl methacrylate (HEMA) hydrogels were prepared using methacrylic acid (MAA), methacrylamide (MAAM), and 4-vinylpyridine (4VP) as co-monomers, and ethylene glycol dimethacrylate (EGDMA) as cross-linker. SNPs binding capacity of hydrogels was evaluated in different concentrations (2, 10, and 20 ppm). In vitro antibacterial activity of SNP-loaded hydrogels was studied against Pseudomonas aeruginosa (P. aeruginosa) isolated from patients' eyes. Then, inhibitory effect of hydrogels in biofilm formation was evaluated in the presence of Staphylococcus epidermidis (S. epidermidis) (DSMZ 3270). Our data indicated that poly(HEMA-co-MAA-co-EGDMA) had superior binding affinity for SNPs in comparison with other hydrogels. All SNP-loaded hydrogels demonstrated excellent antimicrobial effects at all times against P. aeruginosa and S. epidermidis after soaking in 10 and 20 ppm SNP suspensions. Scanning electron microscope (SEM) images revealed excellent inhibitory effect of SNPs against biofilm formation on the surface of the hydrogels. This study indicated the effect of monomer compositions in SNP loading capacity of poly(HEMA) hydrogels and antibacterial efficacy of SNP-loaded hydrogels against P. aeruginosa and S. epidermidis, but further in vivo evaluation is necessary.
Microscopic relaxations in a protein sustained down to 160K in a non-glass forming organic solvent.
Mamontov, E; O'Neill, H
2017-01-01
We have studied microscopic dynamics of a protein in carbon disulfide, a non-glass forming solvent, down to its freezing temperature of ca. 160K. We have utilized quasielastic neutron scattering. A comparison of lysozyme hydrated with water and dissolved in carbon disulfide reveals a stark difference in the temperature dependence of the protein's microscopic relaxation dynamics induced by the solvent. In the case of hydration water, the common protein glass-forming solvent, the protein relaxation slows down in response to a large increase in the water viscosity on cooling down, exhibiting a well-known protein dynamical transition. The dynamical transition disappears in non-glass forming carbon disulfide, whose viscosity remains a weak function of temperature all the way down to freezing at just below 160K. The microscopic relaxation dynamics of lysozyme dissolved in carbon disulfide is sustained down to the freezing temperature of its solvent at a rate similar to that measured at ambient temperature. Our results demonstrate that protein dynamical transition is not merely solvent-assisted, but rather solvent-induced, or, more precisely, is a reflection of the temperature dependence of the solvent's glass-forming dynamics. We hypothesize that, if the long debated idea regarding the direct link between the microscopic relaxations and the biological activity in proteins is correct, then not only the microscopic relaxations, but also the activity, could be sustained in proteins all the way down to the freezing temperature of a non-glass forming solvent with a weak temperature dependence of its viscosity. This article is part of a Special Issue entitled "Science for Life" Guest Editor: Dr. Austen Angell, Dr. Salvatore Magazù and Dr. Federica Migliardo. Copyright © 2016 Elsevier B.V. All rights reserved.
Jana, Batakrishna; Mondal, Goutam; Biswas, Atanu; Chakraborty, Indrani; Saha, Abhijit; Kurkute, Prashant; Ghosh, Surajit
2013-11-01
A versatile method of dual chemical functionalization of graphene oxide (GO) with Tris-[nitrilotris(acetic acid)] (Tris-NTA) and biotin for cellular delivery of oligohistidine- and biotin-tagged biomolecules is reported. Orthogonally functionalized GO surfaces with Tris-NTA and biotin to obtain a dual-functionalized GO (DFGO) are prepared and characterized by various spectroscopic and microscopic techniques. Fluorescence microscopic images reveal that DFGO surfaces are capable of binding oligohistidine-tagged biomolecules/proteins and avidin/biotin-tagged biomolecules/proteins orthogonally. The DFGO nanoparticles are non-cytotoxic in nature and can deliver oligohistidine- and biotin-tagged biomolecules simultaneously into the cell. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Low temperature synthesis of coiled carbon nanotubes and their magnetic properties
NASA Astrophysics Data System (ADS)
Krishna, Vemula Mohana; Somanathan, T.; Manikandan, E.
2018-04-01
In this paper, coiled like structure of carbon nanotubes (c-CNTs) have been effectively grown on bi-metal substituted α-alumina nanoparticles catalyst by chemical vapor deposition (CVD) system. Highly graphitized and dense bundles of carbon product were attained at a low temperature of 550 °C. The coiled carbon nanostructures in very longer lengths were noticed by field emission scanning electron microscope (FESEM) observation. Furthermore, high purity material was achieved, which correlates the energy dispersive x-ray spectroscopy (EDX) analysis. High resolution transmission electron microscope (HRTEM) revealed the diameter and graphitization of coiled structures. The superparamagnetic like behavior was observed at room temperature for the as-synthesized product, which was found by VSM investigation.
Ultrastructural changes in tracheal epithelial cells exposed to oxygen
NASA Technical Reports Server (NTRS)
Philpott, D. E.; Harrison, G. A.; Turnbill, C.; Black, S.
1977-01-01
White albino rats were sacrificed after 24, 36, 48, 72, and 96 h of exposure to 100% O2 at 1 atm. Tissue was prepared for the scanning electron microscope (SEM) by Critical Point Drying and for the transmission electron microscope (TEM) by plastic embedding. Scanning microscopy showed a loss of microvilli after 48 h of exposure. Cilia appeared relatively normal with SEM, but TEM revealed changes in the outer membrane. In TEM, nonciliated cells appeared swollen and often encroached on the ciliated cells. A heavy mucous blanket remained even after processing. All the changes observed that are induced by oxygen exposure contribute to mucostasis, reducing and/or halting mucociliary clearance.
Nasu, Tetsuo
2005-10-01
The resin casts of the respiratory and vascular systems in pigeon lung were examined using a scanning electron microscope. The primary bronchi branched to form many secondary bronchi that anastomosed with each other via the parabronchi. Numerous infundibula protruded from the parabronchi via the atria and ramified into the air capillaries. The pulmonary artery entered into the lung and branched into three vessels that coursed the interparabronchial parts. The intraparabronchial arterioles penetrated the gas-exchange tissue to form the anastomosing networks of blood capillaries. The observation of the double casts of the respiratory and vascular systems revealed three-dimensional complicated networks of air capillaries and blood capillaries.
Improvement of acoustical characteristics : wideband bamboo based polymer composite
NASA Astrophysics Data System (ADS)
Farid, M.; Purniawan, A.; Rasyida, A.; Ramadhani, M.; Komariyah, S.
2017-07-01
Environmental friendly and comfortable materials are desirable for applications in the automobile interior. The objective of this research was to examine and develop bamboo based polymer composites applied to the sound absorption materials of automobile door panels. Morphological analysis of the polyurethane/bamboo powder composite materials was carried out using scanning electron microscope to reveal the microscopic material behavior and followed by the FTIR and TGA testing. The finding demonstrated that this acoustical polymer composite materials provided a potential wideband sound absorption material. The range of frequency can be controlled between 500 and 4000 Hz with an average of sound absorption coefficient around 0.411 and it met to the door panels criteria.
The deflection of carbon composite carbon nanotube / graphene using molecular dynamics simulation
NASA Astrophysics Data System (ADS)
Kolesnikova, A. S.; Kirillova, I. V.; Kossovich, L. U.
2018-02-01
For the first time, the dependence of the bending force on the transverse displacement of atoms in the center of the composite material consisting of graphene and parallel oriented zigzag nanotubes was studied. Mathematical modeling of the action of the needle of the atomic force microscope was carried out using the single-layer armchair carbon nanotube. Armchair nanotubes are convenient for using them as a needle of an atomic force microscope, because their edges are not sharpened (unlike zigzag tubes). Consequently, armchair nanotubes will cause minimal damage upon contact with the investigation object. The geometric parameters of the composite was revealed under the action of the bending force of 6μN.
NASA Technical Reports Server (NTRS)
Stanley, A. G.; Gauthier, M. K.
1977-01-01
A successful diagnostic technique was developed using a scanning electron microscope (SEM) as a precision tool to determine ionization effects in integrated circuits. Previous SEM methods radiated the entire semiconductor chip or major areas. The large area exposure methods do not reveal the exact components which are sensitive to radiation. To locate these sensitive components a new method was developed, which consisted in successively irradiating selected components on the device chip with equal doses of electrons /10 to the 6th rad (Si)/, while the whole device was subjected to representative bias conditions. A suitable device parameter was measured in situ after each successive irradiation with the beam off.
Evaluating coral reef health in American Samoa
Work, Thierry M.; Rameyer, Robert A.
2005-01-01
The study of coral disease has suffered from an absence of systematic approaches that are commonly used to determine causes of diseases in animals. There is a critical need to develop a standardized and portable nomenclature for coral lesions in the field and to incorporate more commonly available biomedical tools in coral disease surveys to determine the potential causes of lesions in corals. We characterized lesions in corals from American Samoa based on gross and microscopic morphology and classified them as discoloration, growth anomalies, or tissue loss. The most common microscopic finding in corals manifesting discoloration was the depletion of zooxanthellae, followed by necrosis, sometimes associated with invasive algae or fungi. The most common microscopic lesion in corals manifesting tissue loss was cell necrosis often associated with algae, fungi, or protozoa. Corals with growth anomaly had microscopic evidence of hyperplasia of gastrovascular canals, followed by necrosis associated with algae or metazoa (polychaete worms). Several species of apparently normal corals also had microscopic changes, including the presence of bacterial aggregates or crustacea in tissues. A single type of gross lesion (e.g., discoloration) could have different microscopic manifestations. This phenomenon underlines the importance of using microscopy to provide a more systematic description of coral lesions and to detect potential pathogens associated with these lesions.
Lunter, Dominique Jasmin
2016-01-01
The aim of the study was to elucidate the effect of sample preparation and microscope configuration on the results of confocal Raman microspectroscopic evaluation of the penetration of a pharmaceutical active into the skin (depth profiling). Pig ear skin and a hydrophilic formulation containing procaine HCl were used as a model system. The formulation was either left on the skin during the measurement, or was wiped off or washed off prior to the analysis. The microscope configuration was varied with respect to objectives and pinholes used. Sample preparation and microscope configuration had a tremendous effect on the results of depth profiling. Regarding sample preparation, the best results could be observed when the formulation was washed off the skin prior to the analysis. Concerning microscope configuration, the use of a 40 × 0.6 numerical aperture (NA) objective in combination with a 25-µm pinhole or a 100 × 1.25 NA objective in combination with a 50-µm pinhole was found to be advantageous. Complete removal of the sample from the skin before the analysis was found to be crucial. A thorough analysis of the suitability of the chosen microscope configuration should be performed before acquiring concentration depth profiles. © 2016 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Siebelmann, Sebastian; Steven, Philipp; Hos, Deniz; Hüttmann, Gereon; Lankenau, Eva; Bachmann, Björn; Cursiefen, Claus
2016-01-01
Boston keratoprosthesis (KPro) type I is a technique to treat patients with corneal diseases that are not amenable to conventional keratoplasty. Correct assembly and central implantation of the prosthesis are crucial for postoperative visual recovery. This study investigates the potential benefit of intraoperative optical coherence tomography (OCT) to monitor KPro surgery. Retrospective case series are presented for two patients who underwent Boston KPro type I implantation. The surgery in both patients was monitored intraoperatively using a commercially available intraoperative OCT (iOCT) device mounted on a surgical microscope. Microscope-integrated intraoperative OCT was able to evaluate the correct assembly and implantation of the KPro. All parts of the prosthesis were visible, and interfaces between the corneal graft and titanium backplate or anterior optics were clearly depictable. Moreover, iOCT visualized a gap between the backplate and graft in one case, and in the other case, a gap between the anterior optic and graft. Neither gap was visible with a conventional surgical microscope. The gap between the anterior optic and the graft could easily be corrected. Microscope-integrated iOCT delivers enhanced information, adding to the normal surgical microscope view during KPro surgery. Correct assembly can be controlled as well as the correct placement of the Boston KPro into the anterior chamber.
Mansoor, Awais; Ahmed, Wamiq M; Samarapungavan, Ala; Cirillo, John; Schwarte, David; Robinson, J Paul; Duerstock, Bradley S
2010-01-01
A web-based application was developed to remotely view slide specimens and control all functions of a research-level light microscopy workstation, called AccessScope. Students and scientists with upper limb mobility and visual impairments are often unable to use a light microscope by themselves and must depend on others in its operation. Users with upper limb mobility impairments and low vision were recruited to assist in the design process of the AccessScope personal computer (PC) user interface. Participants with these disabilities were evaluated in their ability to use AccessScope to perform microscopical tasks. AccessScope usage was compared with inspecting prescanned slide images by grading participants' identification and understanding of histological features and knowledge of microscope operation. With AccessScope subjects were able to independently perform common light microscopy functions through an Internet browser by employing different PC pointing devices or accessibility software according to individual abilities. Subjects answered more histology and microscope usage questions correctly after first participating in an AccessScope test session. AccessScope allowed users with upper limb or visual impairments to successfully perform light microscopy without assistance. This unprecedented capability is crucial for students and scientists with disabilities to perform laboratory coursework or microscope-based research and pursue science, technology, engineering, and mathematics fields.
Juszczak, K; Gil, K; Wyczolkowski, M; Thor, P J
2010-08-01
Neurogenic inflammation is linked to urinary bladder overactivity development. Cyclophosphamide (CYP) damages all mucosal defence lines of urinary bladder and induces cystitis with overactivity. The aim of this study was to estimate the effect of CYP on rat urinary bladder function, histological structure and mastocytes numbers following acute and chronic CYP treatment. Fourty two female rats were divided into four groups: I (control), II (acute cystitis), III (chronic cystitis), IV (sham group). Acute and chronic cystitis were induced by CYP in single dose and four doses (1(st), 3(rd), 5(th), 7(th) day), respectively. In group I-III the cystometric evaluation was performed. Sections of the bladder were stained with HE and toluidine blue for the detection of mastocytes. The severity of inflammation was examined according to mucosal abrasion, haemorrhage, leukocyte infiltration and oedema. Acute and chronic CYP treatment caused inflammatory macroscopic and microscopic changes (mucosal abrasion, haemorrhage, oedema) and increased infiltration of inflammatory cells in urinary bladder. Acute treatment induced the infiltration of mastocytes within bladder wall contrary to chronic one decrement. Acute treatment caused more severe mucosal abrasion, whereas chronic one revealed more developed haemorrhage changes. Additionally, cystometric evaluation revealed urinary bladder overactivity development in both types of cystitis. Basal pressure and detrusor overactivity index after acute treatment increased considerably in comparison with the increase obtained after chronic one. Our results proved that acute model of CYP-induced cystitis in rats is more credible for further evaluation of neurogenic inflammation response in pathogenesis of overactive bladder as compared to chronic one.
Role of anti-adhesive barriers following rotator cuff repair surgery: an experimental study.
Kalem, Mahmut; Şahin, Ercan; Songür, Murat; Zehir, Sinan; Armangil, Mehmet; Demirtaş, Mehmet A
2016-01-01
This experimental study investigates the effectiveness of expanded polytetrafluoroethylene (Dualmesh®, Gore Medical, Flagstaff, AZ, USA), sodium hyaluronate-carboxymethyl cellulose (Seprafilm®, Genzyme, Cambridge, MA, USA), and polysiloxane (silicone) as anti-adhesive barriers for inhibition of fibrosis in the subacromial area following rotator cuff repair. Rabbit rotator cuff tenotomy and repair was conducted on 24 rabbits in 4 groups: control (Group A), Dualmesh® (Group B), Seprafilm® (Group C), and silicone (Group D). Anti-adhesive barrier materials were sutured over the repaired rotator cuff. Macroscopic and histological evaluations were made at the end of the sixth postoperative week. Macroscopic evaluation revealed that minimal adhesion occurred in the control and silicone groups, while the Seprafilm® and Dualmesh® groups showed evidence of fibrosis. Microscopic evaluation revealed diffuse fibrosis and collagen accumulation in the Dualmesh® and Seprafilm® groups, whereas minimal collagen deposition and inflammatory cell reaction was found among the silicone and control groups. Significant differences were found between the silicone and Dualmesh® (p=0.001) and silicone and Seprafilm® groups (p=0.002), as well as between the control and Dualmesh® (p=0.002) and control and Seprafilm® groups (p=0.002). Expanded polytetrafluoroethylene (ePTFE/Dualmesh®) and sodium hyaluronate carboxymethyl cellulose (SH-CMC/Seprafilm®) did not prevent or attenuate postoperative subacromial fibrosis following cuff tear repair. Nor did silicone prevent or attenuate fibrosis. More detailed research is needed for development of an effective anti-adhesive barrier for use after rotator cuff tear surgery.
NASA Astrophysics Data System (ADS)
Yannouleas, Constantine; Brandt, Benedikt B.; Landman, Uzi
2016-07-01
Advances with trapped ultracold atoms intensified interest in simulating complex physical phenomena, including quantum magnetism and transitions from itinerant to non-itinerant behavior. Here we show formation of antiferromagnetic ground states of few ultracold fermionic atoms in single and double well (DW) traps, through microscopic Hamiltonian exact diagonalization for two DW arrangements: (i) two linearly oriented one-dimensional, 1D, wells, and (ii) two coupled parallel wells, forming a trap of two-dimensional, 2D, nature. The spectra and spin-resolved conditional probabilities reveal for both cases, under strong repulsion, atomic spatial localization at extemporaneously created sites, forming quantum molecular magnetic structures with non-itinerant character. These findings usher future theoretical and experimental explorations into the highly correlated behavior of ultracold strongly repelling fermionic atoms in higher dimensions, beyond the fermionization physics that is strictly applicable only in the 1D case. The results for four atoms are well described with finite Heisenberg spin-chain and cluster models. The numerical simulations of three fermionic atoms in symmetric DWs reveal the emergent appearance of coupled resonating 2D Heisenberg clusters, whose emulation requires the use of a t-J-like model, akin to that used in investigations of high T c superconductivity. The highly entangled states discovered in the microscopic and model calculations of controllably detuned, asymmetric, DWs suggest three-cold-atom DW quantum computing qubits.
A super-infection in the cornea caused by Stemphylium, Acremonium, and α-Streptococcus.
Hotta, Fumika; Eguchi, Hiroshi; Nishimura, Keiko; Kogiso, Masahiro; Ishimaru, Mayumi; Kusaka, Shunji; Shimomura, Yoshikazu; Yaguchi, Takashi
2017-03-09
Polymicrobial keratitis with fungus and bacteria can lead to blindness and is challenging to treat. Here, we introduce a case of fungal keratitis caused by two different strains in addition to definite bacterial super-infection caused by an α-Streptococcus sp., and describe the importance of microscopic examination. A 74-year-old woman, who had a past history of infection with leprosy, presented with conjunctival hyperaemia, pain, and corneal opacity in her right eye. Under the presumptive diagnosis of infectious keratitis, corneal scrapings were stained by various reagents and inoculated on several agar plates. Microscopic findings of the scrapings revealed fungi and a small number of Gram-positive cocci. Multiple anti-fungal therapies with levofloxacin ophthalmic solution were administered. Although empiric treatment was initially effective, keratitis recurred 10 days after its initiation. Repeated corneal scraping revealed an abundance of Gram-positive chain cocci and a small amount of fungi, resulting in the switching of an antibiotic medication from levofloxacin to moxifloxacin and cefmenoxime. Keratitis resolved gradually after the conversion. Stemphylium sp., Acremonium sp., and α-Streptococcus sp. were simultaneously isolated from the corneal scrapings. To the best of our knowledge, this is the first case of fungal keratitis caused by Stemphylium sp., and also the first case of super-infection in the cornea caused by two different fungi and one bacterium. Microscopic examination of the corneal scrapings was beneficial in rapid decision of changing to appropriate drug according to the dominancy of pathogenicity.
Dermoscopic and reflectance confocal microscopic features of exogenous ochronosis.
Gil, Inmaculada; Segura, Sonia; Martínez-Escala, Estela; Lloreta, Josep; Puig, Susana; Vélez, Mariano; Pujol, Ramón M; Herrero-González, Josep E
2010-09-01
Exogenous ochronosis presents as an acquired asymptomatic hyperpigmentation on photoexposed areas, predominantly over bony prominences, and is caused by the topical application of several skin-lightening agents. We describe a 63-year-old Hispanic woman who developed exogenous ochronosis lesions on her face after using topical bleaching creams containing hydroquinone, 2% to 3%, and oxybenzone, 2%, for several years. Dermoscopy revealed irregular brown-gray globular, annular, and arciform structures that corresponded to focal deposition of ochronotic pigment on the dermis. These deposits correlated with multiple banana-shaped nonrefractile structures seen using reflectance confocal microscopy. Histopathologic sections revealed the deposition of a banana-shaped, yellow to brown material in the papillary and middle dermis. Ultrastructural examination revealed an amorphous electron-dense material mostly located in the core of elastic fibers and also in smaller amounts in the interstitium with prominent degenerative changes in the elastic fibers. A good correlation was observed between the results of both noninvasive techniques and the diagnostic histologic features of this condition. We characterized by means of dermoscopy, reflectance confocal microscopy, and electronic microscopy a case of exogenous ochronosis. To our knowledge, this is the first description of reflectance confocal microscopic findings in this condition. Dermoscopy and reflectance confocal microscopy are proved to be useful noninvasive techniques for the diagnosis of this pigmentary disorder.
Optical and Probe Diagnostics Applied to Reacting Flows
NASA Technical Reports Server (NTRS)
Ticich, Thomas M.
2003-01-01
The general theme of the research my NASA colleague and I have planned is "Optical and probe diagnostics applied to reacting flows". We plan to explore three major threads during the fellowship period. The first interrogates the flame synthesis of carbon nanotubes using aerosol catalysts. Having demonstrated the viability of the technique for nanotube synthesis, we seek to understand the details of this reacting system which are important to its practical application. Laser light scattering will reveal changes in particle size at various heights above the burner. Analysis of the flame gas by mass spectroscopy will reveal the chemical composition of the mixture. Finally, absorption measurements will map the nanotube concentration within the flow. The second thread explores soot oxidation kinetics. Despite the impact of soot on engine performance, fire safety and pollution, models for its oxidation are inhibited by uncertainty in the values of the oxidation rate. We plan to employ both optical and microscopic measurements to refine this rate. Cavity ring-down absorption measurements of the carbonaceous aerosol can provide a measure of the mass concentration with time and, hence, an oxidation rate. Spectroscopic and direct probe measurements will provide the temperature of the system needed for subsequent modeling. These data will be benchmarked against changes in soot nanostructures as revealed by transmission electron microscopic images from directly sampled material.
NASA Astrophysics Data System (ADS)
Lesage, F.; Castonguay, A.; Tardif, P. L.; Lefebvre, J.; Li, B.
2015-09-01
A combined serial OCT/confocal scanner was designed to image large sections of biological tissues at microscopic resolution. Serial imaging of organs embedded in agarose blocks is performed by cutting through tissue using a vibratome which sequentially cuts slices in order to reveal new tissue to image, overcoming limited light penetration encountered in microscopy. Two linear stages allow moving the tissue with respect to the microscope objective, acquiring a 2D grid of volumes (1x1x0.3 mm) with OCT and a 2D grid of images (1x1mm) with the confocal arm. This process is repeated automatically, until the entire sample is imaged. Raw data is then post-processed to re-stitch each individual acquisition and obtain a reconstructed volume of the imaged tissue. This design is being used to investigate correlations between white matter and microvasculature changes with aging and with increase in pulse pressure following transaortic constriction in mice. The dual imaging capability of the system allowed to reveal different contrast information: OCT imaging reveals changes in refractive indices giving contrast between white and grey matter in the mouse brain, while transcardial perfusion of FITC or pre-sacrifice injection of Evans Blue shows microsvasculature properties in the brain with confocal imaging.
Andersson, Richard L.; Ström, Valter; Gedde, Ulf W.; Mallon, Peter E.; Hedenqvist, Mikael S.; Olsson, Richard T.
2014-01-01
A missing cornerstone in the development of tough micro/nano fibre systems is an understanding of the fibre failure mechanisms, which stems from the limitation in observing the fracture of objects with dimensions one hundredth of the width of a hair strand. Tensile testing in the electron microscope is herein adopted to reveal the fracture behaviour of a novel type of toughened electrospun poly(methyl methacrylate)/poly(ethylene oxide) fibre mats for biomedical applications. These fibres showed a toughness more than two orders of magnitude greater than that of pristine PMMA fibres. The in-situ microscopy revealed that the toughness were not only dependent on the initial molecular alignment after spinning, but also on the polymer formulation that could promote further molecular orientation during the formation of micro/nano-necking. The true fibre strength was greater than 150 MPa, which was considerably higher than that of the unmodified PMMA (17 MPa). This necking phenomenon was prohibited by high aspect ratio cellulose nanocrystal fillers in the ultra–tough fibres, leading to a decrease in toughness by more than one order of magnitude. The reported necking mechanism may have broad implications also within more traditional melt–spinning research. PMID:25208692
Dixit, Rahul P; Nagarsenker, Mangal S
2010-12-01
The study describes development of solid microemulsions (SME) for improved delivery of simvastatin (SMV). Pseudo-ternary phase diagrams were constructed and MEs were optimized for oil and drug content. SMEs were prepared using colloidal silicon dioxide to adsorb the liquid ME. MEs were characterized for mean globule size in aqueous medium and the SMEs were evaluated for powder characteristics, mean globule size after dilution with water, dissolution profile and for in vivo efficacy in rats. X-ray diffraction studies indicated complete amorphization and/or solubilization of SMV in the SMEs. It was supported by scanning electronic microscopic studies, which did not show evidence of precipitation of the drug on the surface of the carrier. Dissolution studies revealed remarkable increase in dissolution of the drug as compared to plain drug. All the formulations provided significant reduction in the total cholesterol levels in hyperlipidemic rats with reference to rats of control group (p < 0.05). The proposed SMEs have potential to deliver water insoluble drugs like SMV by oral route for better efficacy. © 2010 Wiley-Liss, Inc. and the American Pharmacists Association
Clinical and prognostic aspects of adrenocortical neoplasms in childhood.
Teinturier, C; Pauchard, M S; Brugières, L; Landais, P; Chaussain, J L; Bougnères, P F
1999-02-01
A retrospective study of 54 children was undertaken to define the clinical presentation and secretory patterns of adrenal tumors and to evaluate the outcome of surgical resection and medical therapy. Different factors were studied in univariate and multivariate analysis by using the Cox proportional hazard model. Median age at diagnosis was 4 years. Boys and girls were affected equally. The disease was revealed by virilization (61%) or by a palpable mass (39%) with a 0.1-5.5 year delay from initial symptoms. At initial examination, we found that 76% of children were virilized. Ninety-four percent of the tested tumors secreted androgens, which were associated with glucocorticoids in 36%. Adrenal tumors in children were smaller than in adults. Half of them measured less than 10 cm. There were recurrences in 40% of children. The survival rate at 5 years was 49%, 70% if resection was microscopically complete and 7% if not (P < 0.001). In children, rare adrenal tumors have different diagnostic and prognostic characteristics than in adults; however, recurrences remain frequent. The efficacy of chemotherapy, mainly o,p'-DDD (Mitotane), remains to be evaluated in comparative trials.
Dubey, J P
2018-04-25
Water buffalo (Bubalus bubalis) is important for the economy of Asia, South America and parts of Europe. Coccidiosis is an important cause of neonatal mortality in livestock, including buffalo. Of more than 12 species of Eimeria in buffalo, Eimeria bareillyi is the most pathogenic. There are uncertainties concerning its asexual and sexual development. During a previously reported outbreak of fatal enteritis associated with E. bareillyi in buffaloes in the Netherlands, sections of small intestine were re-evaluated histologically and by transmission electron microscopy (TEM) to seek details of endogenous development. Profuse asexual multiplication occurred in the jejunum and ileum. Light microscopic examination revealed that parasites divided in two (probably endodyogeny) or more organisms. There were two or more generations of morphologically different merozoites; some of these observations were confirmed by TEM. Details of gametogonic development, including oocyst wall formation are provided. Schizogonic and gametogonic development described in the present study can serve as a guide for differential diagnosis of Eimeria species in histological sections of intestines of buffaloes.
Yilmaz, Yucel; Dalmis, Anya; Gurbuz, Taskin; Simsek, Sera
2004-12-01
The aim of this investigation was to compare the tensile strength, microleakage, and Scanning Electron Microscope (SEM) evaluations of SSCs cemented using different adhesive cements on primary molars. Sixty-three extracted primary first molars were used. Tooth preparations were done. Crowns were altered and adapted for investigation purpose, and then cemented using glass ionomer cement (Aqua Meron), resin modified cement (RelyX Luting), and resin cement (Panavia F) on the prepared teeth. Samples were divided into two groups of 30 samples each for tensile strength and microleakage tests. The remaining three samples were used for SEM evaluation. Data were analyzed with one-way ANOVA and Tukey test. The statistical analysis of ANOVA revealed significant differences among the groups for both tensile strength and microleakage tests (p < 0.05). Tukey test showed statistically significant difference between Panavia F and RelyX Luting (p < 0.05), but none between the others (p > 0.05). This study showed that the higher the retentive force a crown possessed, the lower would be the possibility of microleakage.
NASA Astrophysics Data System (ADS)
Yang, Xiaochen; Clements, Logan W.; Luo, Ma; Narasimhan, Saramati; Thompson, Reid C.; Dawant, Benoit M.; Miga, Michael I.
2017-03-01
Intra-operative soft tissue deformation, referred to as brain shift, compromises the application of current imageguided surgery (IGS) navigation systems in neurosurgery. A computational model driven by sparse data has been used as a cost effective method to compensate for cortical surface and volumetric displacements. Stereoscopic microscopes and laser range scanners (LRS) are the two most investigated sparse intra-operative imaging modalities for driving these systems. However, integrating these devices in the clinical workflow to facilitate development and evaluation requires developing systems that easily permit data acquisition and processing. In this work we present a mock environment developed to acquire stereo images from a tracked operating microscope and to reconstruct 3D point clouds from these images. A reconstruction error of 1 mm is estimated by using a phantom with a known geometry and independently measured deformation extent. The microscope is tracked via an attached tracking rigid body that facilitates the recording of the position of the microscope via a commercial optical tracking system as it moves during the procedure. Point clouds, reconstructed under different microscope positions, are registered into the same space in order to compute the feature displacements. Using our mock craniotomy device, realistic cortical deformations are generated. Our experimental results report approximately 2mm average displacement error compared with the optical tracking system. These results demonstrate the practicality of using tracked stereoscopic microscope as an alternative to LRS to collect sufficient intraoperative information for brain shift correction.
Habibi, Gholamreza; Esmaeilnia, Kasra; Hablolvarid, Mohammad Hasan; Afshari, Asghar; Zamen, Mohsen; Bozorgi, Soghra
2016-01-01
Equine piroplasmosis (EP) is the cause of persistent tick-borne infection with no symptoms, but the most important problem of EP is due to the persistent carrier state. Carrier animals to Babesia (Theileria) equi (Laveran 1901) and B. caballi (Nuttall, 1910) infestation could be identified by extremely sensitive PCR-based method. The purpose of this study was to identify the causative agents of equine piroplasmosis based on molecular and microscopic assays in equids from Kurdistan Province, Iran. Thirty one horse and mule blood samples were used with history of living in Kurdistan Province of Iran. The blood specimens were utilized for T. equi and B. caballi DNA identification by PCR and Giemsa stained smears for microscopic observation. The results clearly showed the presence of B. (Theileria) equi DNA in 30 of 31 blood samples (96.77%), but the microscopic examination revealed the 3 of 31 positive Babesia like organisms in the red blood cells (9.67%). The obtained results demonstrated the presence of hidden B. (Theileria) equi infection in horses with previous habitance in Kurdistan Province of Iran. The carrier animals became a main source of infection and can transmit the disease. Therefore, hidden infection might be considered as a health threatening and limiting factor in animals used in therapeutic antisera research and production centers.
Method to deterministically study photonic nanostructures in different experimental instruments.
Husken, B H; Woldering, L A; Blum, C; Vos, W L
2009-01-01
We describe an experimental method to recover a single, deterministically fabricated nanostructure in various experimental instruments without the use of artificially fabricated markers, with the aim to study photonic structures. Therefore, a detailed map of the spatial surroundings of the nanostructure is made during the fabrication of the structure. These maps are made using a series of micrographs with successively decreasing magnifications. The graphs reveal intrinsic and characteristic geometric features that can subsequently be used in different setups to act as markers. As an illustration, we probe surface cavities with radii of 65 nm on a silica opal photonic crystal with various setups: a focused ion beam workstation; a scanning electron microscope (SEM); a wide field optical microscope and a confocal microscope. We use cross-correlation techniques to recover a small area imaged with the SEM in a large area photographed with the optical microscope, which provides a possible avenue to automatic searching. We show how both structural and optical reflectivity data can be obtained from one and the same nanostructure. Since our approach does not use artificial grids or markers, it is of particular interest for samples whose structure is not known a priori, like samples created solely by self-assembly. In addition, our method is not restricted to conducting samples.
Wang, Zhen; Xiao, Zhiyu; Huang, Chuanshou; Wen, Liping; Zhang, Weiwen
2017-01-01
The present article studied the effect of ultrasonic surface rolling process (USRP) on the microstructure and wear behavior of a selective laser melted Ti-6Al-4V alloy. Surface characteristics were investigated using optical microscope, nano-indentation, scanning electron microscope, transmission electron microscope and laser scanning confocal microscope. Results indicated that the thickness of pore-free surfaces increased to 100~200 μm with the increasing ultrasonic surface rolling numbers. Severe work hardening occurred in the densified layer, resulting in the formation of refined grains, dislocation walls and deformation twins. After 1000 N 6 passes, about 15.5% and 14.1% increment in surficial Nano-hardness and Vickers-hardness was obtained, respectively. The hardness decreased gradually from the top surface to the substrate. Wear tests revealed that the friction coefficient declined from 0.74 (polished surface) to 0.64 (USRP treated surface) and the wear volume reduced from 0.205 mm−3 to 0.195 mm−3. The difference in wear volume between USRP treated and polished samples increased with sliding time. The enhanced wear resistance was concluded to be associated with the improvement of hardness and shear resistance and also the inhibition of delamination initiation. PMID:29048344
Noise induced chaos in optically driven colloidal rings.
NASA Astrophysics Data System (ADS)
Roichman, Yael; Zaslavsky, George; Grier, David G.
2007-03-01
Given a constant flux of energy, many driven dissipative systems rapidly organize themselves into configurations that support steady state motion. Examples include swarming of bacterial colonies, convection in shaken sandpiles, and synchronization in flowing traffic. How simple objects interacting in simple ways self-organize generally is not understood, mainly because so few of the available experimental systems afford the necessary access to their microscopic degrees of freedom. This talk introduces a new class of model driven dissipative systems typified by three colloidal spheres circulating around a ring-like optical trap known as an optical vortex. By controlling the interplay between hydrodynamic interactions and fixed disorder we are able to drive a transition from a previously predicted periodic steady state to fully developed chaos. In addition, by tracking both microscopic trajectories and macroscopic collective fluctuations the relation between the onset of microscopic weak chaos and the evolution of space-time self-similarity in macroscopic transport properties is revealed. In a broader scope, several optical vortices can be coupled to create a large dissipative system where each building block has internal degrees of freedom. In such systems the little understood dynamics of processes like frustration and jamming, fluctuation-dissipation relations and the propagation of collective motion can be tracked microscopically.
Bile acid malabsorption in patients with chronic diarrhoea: clinical value of SeHCAT test.
Wildt, S; Nørby Rasmussen, S; Lysgård Madsen, J; Rumessen, J J
2003-08-01
Bile acid malabsorption (BAM), a cause of chronic diarrhoea, can be diagnosed by the SeHCAT test. The purpose of this study was to evaluate the usefulness of SeHCAT testing by assessing the extent of BAM and describing the clinical characteristics in a group of patients with chronic diarrhoea. Clinical outcome after treatment with cholestyramine was also evaluated. During a 5-year period (1997-2001) the SeHCAT test was performed in 135 patients in whom a primary programme for diagnostic evaluation of chronic diarrhoea had not revealed a cause. File data from 133 patients could be evaluated. In 44% of patients, bile acid absorption was normal with SeHCAT retention > or = 15%. Impaired SeHCAT retention was found in 56%. All patients with ileocaecal resections had retention values < 10%. Patients with microscopic colitis presented with BAM in 39%. Only one patient with idiopathic BAM presented with steatorrhoea as opposed to 11 patients with type 1 and 3 BAM. Patients with idiopathic BAM and/or SeHCAT retention values < 5% had the best response to treatment with cholestyramine. The SeHCAT test is of value in evaluation of patients with chronic diarrhoea as a second-line investigation with a high diagnostic yield. The only a priori parameter to predict BAM was the existence of ileocaecal resections. The result of the SeHCAT test seems to predict the benefit of treatment with cholestyramine.
Microscopic diffusion anisotropy in the human brain: Age-related changes.
Lawrenz, Marco; Brassen, Stefanie; Finsterbusch, Jürgen
2016-11-01
The fractional anisotropy (FA) that can be derived from diffusion tensor imaging (DTI), is ambiguous because it not only depends on the tissue microstructure but also on the axon or fiber orientation distribution within a voxel. Measures of the microscopic diffusion anisotropy, like the microscopic anisotropy index (MA) that can be determined with so-called double-wave-vector (DWV) or double diffusion encoding (DDE) imaging, are independent of this orientation distribution and, thus, offer a more direct and undisguised access to the tissue structure on a cellular or microscopic scale. In this study, FA and MA measurements were performed in a group of aged (>60y), healthy volunteers and compared to the data obtained recently for a group of young (<33y), healthy volunteers to reveal age-related differences. The coefficients-of-variation (CV) determined for the aged group were considerably lower for MA than for FA in average and in most of the 16 ROIs analyzed due to lower between-subject variations of MA. FA differences between the young and the aged group were in line with previous DTI studies. MA was also decreased in the aged group but in more of the 16 ROIs and with a higher significance. Furthermore, MA differences were also observed in frontal brain regions containing fiber crossings that did not reveal significant FA differences, i.e. MA seems to provide a better sensitivity to detect microstructural changes in such regions. In some non-cortical gray matter structures like the putamen, FA was increased but MA was decreased in the aged group which could indicate a coherent fiber orientation in the aged group related to the loss of crossing or fanning fibers. In conclusion, MA not only could improve the detectability of differences of the tissue microstructure but, in conjunction with FA, could also help to identify the underlying changes. Copyright © 2016 Elsevier Inc. All rights reserved.
[In vitro and in vivo antibacterial activities of sulopenem, a new penem antibiotic].
Komoto, A; Otsuki, M; Nishino, T
1996-04-01
The in vitro and in vivo antibacterial activities of sulopenem, a new penem, were evaluated in comparison with imipenem (IPM), meropenem (MEPM), ceftazidime (CAZ) and flomoxef (FMOX). Sulopenem had broad and potent antibacterial spectra against Gram-positive and Gram-negative bacteria, including Enterococcus faecalis, Proteus vulgaris, Morganella morganii, Enterobacter spp. and Citrobacter freundii. Sulopenem showed concentration-dependent bactericidal activities against Staphylococcus aureus, Escherichia coli, Klebsiella pneumoniae and Acinetobacter calcoaceticus. Morphological observation using phase-contrast microscope revealed that sulopenem induced spherical cell formation with E. coli and K. pneumoniae at lower concentrations and bacteriolysis at higher concentrations. Therapeutic efficacies of sulopenem against systemic infections in mice were almost equal to those of imipenem against Streptococcus pneumoniae. While its therapeutic efficacies were superior to those of meropenem, ceftazidime and flomoxef against S. aureus and S. pneumoniae, they were inferior to those of imipenem/cilastatin against S. aureus, K. pneumoniae and A. calcoaceticus.
In-situ evaluation of the degradable carbon influence for industrial waste water treatment
NASA Astrophysics Data System (ADS)
Fayomi, O. S. I.; Olukanni, D. O.; Fayomi, G. U.; Joseph, O. O.; Popoola, A. P. I.
2016-07-01
A photochemical investigation and synergetic blend for wastewater purification was carried out. Blends of different peels: Potato-, Apple and Pineapples-peals (PAP-peals) were impregnated with aqueous solutions of ZnCl2 following the variant of the incipient wetness method for activation of activated carbon (AC). Different concentrations were used to produce impregnation ratios. Activation was carried out in a tube furnace by heating to 700°C with 1 hour soaking time. Scanning Electron Microscopic with attached energy dispersive spectrometer (SEM/EDS), Atomic Adsorption Spectrometry (AAS) and Fourier Transform Infrared spectrometer (FTIS) equipments were used for the characterization of the AC produced. The result shows that PAP-peals derived activated carbons had micro porous characteristics. The study revealed that these new combined adsorbents materials are inexpensive, easily available and they have applications for the removal of Cu, Pb and Cr contained in industrial effluents.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deibler, Lisa Anne; Brown, Arthur; Puskar, Joseph D.
Drawn 304L stainless steel tubing was subjected to 42 different annealing heat treatments with the goal of initializing a microstructural model to select a heat treatment to soften the tubing from a hardness of 305 Knoop to 225–275 Knoop. The amount of recrystallization and grain size caused by 18 heat treatments were analyzed via optical microscopy and image analysis, revealing the full range of recrystallization from 0 to 100%. The formation of carbides during the longer duration and higher-temperature heat treatments was monitored via transmission electron microscope evaluation. The experimental results informed a model which includes recovery, recrystallization, and grainmore » growth to predict microstructure and hardness. After initialization of the model, it was able to predict hardness with a R 2 value of 0.95 and recrystallization with an R 2 value of 0.99. As a result, the model was then utilized in the design and testing of a heat treatment to soften the tubing.« less
Changes in functional metabolism in the rat central nervous system following spaceflight
NASA Technical Reports Server (NTRS)
Murakami, D. M.; Miller, J. D.; Fuller, C. A.
1985-01-01
The neuronal metabolism and soma size of neurons within the paraventricular nucleus (PVN) and the supraoptic nucleus of rats are analyzed. Five male Sprague-Dawley rats were flown on Spacelab 3 for 7 days under a 12:12 light/dark cycle and unlimited food and water, and a control group was kept on the ground under similar conditions. The preparation of the hypothalamus of the rats for microscopic examination using thionin or the cytochrome oxidase (CYOX) technique is described. CYOX activity and soma size within the PVN are evaluated. The effects of water drinking pattern and space flight on CYOX activity and soma size are investigated. The data reveal that the flight rats with normal drinking patterns display a decrease in neuronal metabolism within the vasopressin-containing neurons of the hypothalamus and this metabolic change may reflect fluid shifts caused by microgravity.
Ghosh, Sudipta; Indukuri, Kiran; Bondalapati, Somasekhar; Saikia, Anil K; Rangan, Latha
2013-08-01
The labdane diterpene, (E)-labda-8(17), 12-diene-15, 16-dial (compound A) and its epoxide analogue, (E)-8β, 17-Epoxylabd-12-ene-15, 16-dial (compound B) were isolated from the seeds of Alpinia nigra for the first time. The antibacterial activities of both compounds were evaluated against three Gram-positive and four Gram-negative bacteria, and flow cytometric analysis revealed that these compounds caused significant damage to the bacterial cell membranes. Further, field emission scanning electron microscope imaging and cell leakage analysis confirmed that the labdane diterpenes were responsible for bacterial cell membrane damage and disintegration. Our findings provide new insight into the broad-spectrum effects of two natural labdane diterpenes that may be useful in the future development of herbal antibiotic products. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
In-situ evaluation of the degradable carbon influence for industrial waste water treatment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fayomi, O. S. I., E-mail: ojo.fayomi@covenantuniversity.edu.ng, E-mail: fayomio@tut.ac.za, E-mail: ojosundayfayomi3@gmail.com; Department of Chemical, Metallurgical and Materials Engineering, Tshwane University of Technology, P.M.B. X680, Pretoria; Olukanni, D. O.
A photochemical investigation and synergetic blend for wastewater purification was carried out. Blends of different peels: Potato-, Apple and Pineapples-peals (PAP-peals) were impregnated with aqueous solutions of ZnCl{sub 2} following the variant of the incipient wetness method for activation of activated carbon (AC). Different concentrations were used to produce impregnation ratios. Activation was carried out in a tube furnace by heating to 700°C with 1 hour soaking time. Scanning Electron Microscopic with attached energy dispersive spectrometer (SEM/EDS), Atomic Adsorption Spectrometry (AAS) and Fourier Transform Infrared spectrometer (FTIS) equipments were used for the characterization of the AC produced. The result showsmore » that PAP-peals derived activated carbons had micro porous characteristics. The study revealed that these new combined adsorbents materials are inexpensive, easily available and they have applications for the removal of Cu, Pb and Cr contained in industrial effluents.« less
NASA Astrophysics Data System (ADS)
Pomorski, K.; Nerlo-Pomorska, B.; Bartel, J.; Schmitt, C.
2018-03-01
The fission-fragment mass and total kinetic energy (TKE) distributions are evaluated in a quantum mechanical framework using elongation, mass asymmetry, neck degree of freedom as the relevant collective parameters in the Fourier shape parametrization recently developed by us. The potential energy surfaces (PES) are calculated within the macroscopic-microscopic model based on the Lublin-Strasbourg Drop (LSD), the Yukawa-folded (YF) single-particle potential and a monopole pairing force. The PES are presented and analysed in detail for even-even Plutonium isotopes with A = 236-246. They reveal deep asymmetric valleys. The fission-fragment mass and TKE distributions are obtained from the ground state of a collective Hamiltonian computed within the Born-Oppenheimer approximation, in the WKB approach by introducing a neck-dependent fission probability. The calculated mass and total kinetic energy distributions are found in good agreement with the data.
Intestinal leishmaniasis in acquired immunodeficiency syndrome.
Molaei, M; Minakari, M; Pejhan, Sh; Mashayekhi, R; Modaress Fatthi, A R; Zali, M R
2011-05-01
In endemic regions, visceral leishmaniasis is one of the most common opportunistic infections in HIV positive patients. Simultaneous infection with Leishmania and HIV has been reported in some countries but this is the first report of such a case in Iran. Our patient was a 27 years old man with intermittent night fever, abdominal pain, loss of appetite, vomiting, watery diarrhea and severe weight loss for 6 months. He had low socio-economic status with an imprisonment history. The patient was quite cachectic and had low grade fever. Physical exam and upper GI endoscopy revealed oropharyngeal candidiasis. Microscopic evaluation of duodenal biopsy material showed Leishmania amastigotes in macrophages of lamina propria. Leishman bodies were also observed in bone marrow aspiration specimen. Serologic tests were positive for Leishmania infantum. HIV antibody was also positive with a CD4+cell count of 80/μl. The diagnosis was acquired immunodeficiency syndrome with simultaneous visceral leishmaniasis involving intestinal mucosa.
Relevant principal factors affecting the reproducibility of insect primary culture.
Ogata, Norichika; Iwabuchi, Kikuo
2017-06-01
The primary culture of insect cells often suffers from problems with poor reproducibility in the quality of the final cell preparations. The cellular composition of the explants (cell number and cell types), surgical methods (surgical duration and surgical isolation), and physiological and genetic differences between donors may be critical factors affecting the reproducibility of culture. However, little is known about where biological variation (interindividual differences between donors) ends and technical variation (variance in replication of culture conditions) begins. In this study, we cultured larval fat bodies from the Japanese rhinoceros beetle, Allomyrina dichotoma, and evaluated, using linear mixed models, the effect of interindividual variation between donors on the reproducibility of the culture. We also performed transcriptome analysis of the hemocyte-like cells mainly seen in the cultures using RNA sequencing and ultrastructural analyses of hemocytes using a transmission electron microscope, revealing that the cultured cells have many characteristics of insect hemocytes.
Voylov, Dmitry N.; Holt, Adam P.; Doughty, Benjamin; ...
2017-01-10
In this paper, the structure and polymer–nanoparticle interactions among physically adsorbed poly(2-vinylpyridine) chains on the surface of silica nanoparticles (NPs) were systematically studied as a function of molecular weight (MW) by sum frequency generation (SFG) and X-ray photoelectron (XPS) spectroscopies. Analysis of XPS data identified hydrogen bonds between the polymer and NPs, while SFG evaluated the change in the number of free OH sites on the NP’s surface. Our data revealed that the hydrogen bonds and amount of the free ¯OH sites have a significant dependence on the polymer’s MW. Finally, these results provide clear experimental evidence that the interactionmore » of physically adsorbed chains with nanoparticles is strongly MW dependent and aids in unraveling the microscopic mechanism responsible for the strong MW dependence of dynamics of the interfacial layer in polymer nanocomposites.« less
Oxygen Nanobubble Tracking by Light Scattering in Single Cells and Tissues.
Bhandari, Pushpak; Wang, Xiaolei; Irudayaraj, Joseph
2017-03-28
Oxygen nanobubbles (ONBs) have significant potential in targeted imaging and treatment in cancer diagnosis and therapy. Precise localization and tracking of single ONBs is demonstrated based on hyperspectral dark-field microscope (HSDFM) to image and track single oxygen nanobubbles in single cells. ONBs were proposed as promising contrast-generating imaging agents due to their strong light scattering generated from nonuniformity of refractive index at the interface. With this powerful platform, we have revealed the trajectories and quantities of ONBs in cells, and demonstrated the relation between the size and diffusion coefficient. We have also evaluated the presence of ONBs in the nucleus with respect to an increase in incubation time and have quantified the uptake in single cells in ex vivo tumor tissues. Our results demonstrate that HSDFM can be a versatile platform to detect and measure cellulosic nanoparticles at the single-cell level and to assess the dynamics and trajectories of this delivery system.
Graphene oxide nanostructures modified multifunctional cotton fabrics
NASA Astrophysics Data System (ADS)
Krishnamoorthy, Karthikeyan; Navaneethaiyer, Umasuthan; Mohan, Rajneesh; Lee, Jehee; Kim, Sang-Jae
2012-06-01
Surface modification of cotton fabrics using graphene oxide (GO) nanostructures was reported. Scanning electron microscopic (SEM) investigations revealed that the GO nanostructure was coated onto the cotton fabric. The molecular level interaction between the graphene oxide and the cotton fabric is studied in detail using the Fourier transform infra-red (FTIR) spectra. Thermogravimetric analysis (TGA) showed that GO loaded cotton fabrics have enhanced thermal stability compared to the bare cotton fabrics. The photocatalytic activity of the GO-coated cotton fabrics was investigated by measuring the photoreduction of resazurin (RZ) into resorufin (RF) under UV light irradiation. The antibacterial activity was evaluated against both Gram-negative and Gram-positive bacteria and the results indicated that the GO-coated cotton fabrics are more toxic towards the Gram-positive ones. Our results provide a way to develop graphene oxide-based devices for the biomedical applications for improving health care.
NASA Astrophysics Data System (ADS)
Hazeli, K.; Cuadra, J.; Vanniamparambil, P. A.; Carmi, R.; Kontsos, A.
This study presents a hybrid experimental mechanics approach combining multi-scale mechanical testing, in situ nondestructive evaluation and targeted microscopic quantification to identify and quantify critical micro structural parameters that affect properties and overall plasticity of Mg alloys. Room temperature monotonic and cyclic experiments monitored by Digital Image Correlation (DIC) coupled with Acoustic Emission (AE) of Mg Alloys of the AZ series were used for this investigation. Data obtained using the optico-acoustic nondestructive system revealed for the first time the direct connection between surface strain localization effects similar to Luder's bands and pronounced twin activity. Electron Back Scatter Diffraction (EBSD) measurements showed the profuse and spatially inhomogeneous nature of twinning at early stages of plasticity which is related with the onset of yielding and the macroscopic plateau region in the stress-strain curve. Furthermore, twinning/detwinning activity was identified in several grains of tested specimens and during characteristic points of fatigue cycles.
Abeywickrama, Chathura S; Baumann, Hannah J; Alexander, Nicolas; Shriver, Leah P; Konopka, Michael; Pang, Yi
2018-05-09
A series of benzothiazolium-based hemicyanines (3a-3f) have been synthesized. Evaluation of their photophysical properties shows that they exhibit improved photophysical characteristics. In comparison with the available commercial MitoTrackers, the new probes revealed an enhanced Stokes shift (Δλ ∼ 80 nm) and minimized aggregation for increased sensitivity. The synthesized probes are found to exhibit excellent selectivity for mitochondrial staining in an oligodendrocyte cell line. Probes show almost no fluorescence in aqueous environments, while the fluorescence is increased by ∼10-fold in organic solvents, making it possible for mitochondrial imaging without the need for post-staining washing. Since the absorption peaks of probes are close to the laser wavelengths of 561 and 640 nm on a commercial confocal microscope, e.g.3a exhibits λabs ∼ 620 nm and λem ∼ 702 nm, they could be useful probes for mitochondrial tracking in live cells.
Comments on ”Evidence of the hydrogen release mechanism in bulk MgH2”
NASA Astrophysics Data System (ADS)
Surrey, Alexander; Nielsch, Kornelius; Rellinghaus, Bernd
2017-04-01
The effect of an electron beam induced dehydrogenation of MgH2 in the transmission electron microscope (TEM) is largely underestimated by Nogita et al., and led the authors to a misinterpretation of their TEM observations. Firstly, the selected area diffraction (SAD) pattern is falsely interpreted. A re-evaluation of the SAD pattern reveals that no MgH2 is present in the sample, but that it rather consists of Mg and MgO only. Secondly, the transformation of the sample upon in-situ heating in the TEM cannot be ascribed to dehydrogenation, but is rather to be explained by the (nanoscale) Kirkendall effect, which leads to the formation of hollow MgO shells without any metallic Mg in their cores. Hence, the conclusions drawn from the TEM investigation are invalid, as the authors apparently have never studied MgH2.
Qualitative investigation of fresh human scalp hair with full-field optical coherence tomography
NASA Astrophysics Data System (ADS)
Choi, Woo June; Pi, Long-Quan; Min, Gihyeon; Lee, Won-Soo; Lee, Byeong Ha
2012-03-01
We have investigated depth-resolved cellular structures of unmodified fresh human scalp hairs with ultrahigh-resolution full-field optical coherence tomography (FF-OCT). The Linnik-type white light interference microscope has been home-implemented to observe the micro-internal layers of human hairs in their natural environment. In hair shafts, FF-OCT has qualitatively revealed the cellular hair compartments of cuticle and cortex layers involved in keratin filaments and melanin granules. No significant difference between black and white hair shafts was observed except for absence of only the melanin granules in the white hair, reflecting that the density of the melanin granules directly affects the hair color. Anatomical description of plucked hair bulbs was also obtained with the FF-OCT in three-dimensions. We expect this approach will be useful for evaluating cellular alteration of natural hairs on cosmetic assessment or diagnosis of hair diseases.
The Microstructure of Lunar Micrometeorite Impact Craters
NASA Technical Reports Server (NTRS)
Noble, S. K.; Keller, L. P.; Christoffersen, R.; Rahman, Z.
2016-01-01
The peak of the mass flux of impactors striking the lunar surface is made up of objects approximately 200 micrometers in diameter that erode rocks, comminute regolith grains, and produce agglutinates. The effects of these micro-scale impacts are still not fully understood. Much effort has focused on evaluating the physical and optical effects of micrometeorite impacts on lunar and meteoritic material using pulsed lasers to simulate the energy deposited into a substrate in a typical hypervelocity impact. Here we characterize the physical and chemical changes that accompany natural micrometeorite impacts into lunar rocks with long surface exposure to the space environment (12075 and 76015). Transmission electron microscope (TEM) observations were obtained from cross-sections of approximately 10-20 micrometers diameter craters that revealed important micro-structural details of micrometeorite impact processes, including the creation of npFe (sup 0) in the melt, and extensive deformation around the impact site.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Voylov, Dmitry N.; Holt, Adam P.; Doughty, Benjamin
In this paper, the structure and polymer–nanoparticle interactions among physically adsorbed poly(2-vinylpyridine) chains on the surface of silica nanoparticles (NPs) were systematically studied as a function of molecular weight (MW) by sum frequency generation (SFG) and X-ray photoelectron (XPS) spectroscopies. Analysis of XPS data identified hydrogen bonds between the polymer and NPs, while SFG evaluated the change in the number of free OH sites on the NP’s surface. Our data revealed that the hydrogen bonds and amount of the free ¯OH sites have a significant dependence on the polymer’s MW. Finally, these results provide clear experimental evidence that the interactionmore » of physically adsorbed chains with nanoparticles is strongly MW dependent and aids in unraveling the microscopic mechanism responsible for the strong MW dependence of dynamics of the interfacial layer in polymer nanocomposites.« less
Homogeneous lithium electrodeposition with pyrrolidinium-based ionic liquid electrolytes.
Grande, Lorenzo; von Zamory, Jan; Koch, Stephan L; Kalhoff, Julian; Paillard, Elie; Passerini, Stefano
2015-03-18
In this study, we report on the electroplating and stripping of lithium in two ionic liquid (IL) based electrolytes, namely N-butyl-N-methylpyrrolidinium bis(fluorosulfonyl) imide (Pyr14FSI) and N-butyl-N-methylpyrrolidinium bis(trifluoromethanesulfonyl)imide (Pyr14TFSI), and mixtures thereof, both on nickel and lithium electrodes. An improved method to evaluate the Li cycling efficiency confirmed that homogeneous electroplating (and stripping) of Li is possible with TFSI-based ILs. Moreover, the presence of native surface features on lithium, directly observable via scanning electron microscope imaging, was used to demonstrate the enhanced electrolyte interphase (SEI)-forming ability, that is, fast cathodic reactivity of this class of electrolytes and the suppressed dendrite growth. Finally, the induced inhomogeneous deposition enabled us to witness the SEI cracking and revealed previously unreported bundled Li fibers below the pre-existing SEI and nonrod-shaped protuberances resulting from Li extrusion.
NASA Astrophysics Data System (ADS)
Habibullah, Parvaiz; Siddiqui, Ghazala; Saleem, Yasir
2017-05-01
Seashells are comprised largely of a brittle ceramic material (calcite, the stuff of chalk) in the form of microscopic slates. Shells, such as the abalones, reinforced with a kind of protein mortar in efforts to evaluate on how seashells repair themselves. We have identified the protein and mechanism on how the protein mortar stretches itself into ligaments that bridge the gap, with the help of scanning electron microscope (SEM).
A 25% tannic acid solution as a root canal irrigant cleanser: a scanning electron microscope study.
Bitter, N C
1989-03-01
A scanning electron microscope was used to evaluate the cleansing properties of a 25% tannic acid solution on the dentinal surface in the pulp chamber of endodontically prepared teeth. This was compared with the amorphous smear layer of the canal with the use of hydrogen peroxide and sodium hypochlorite solution as an irrigant. The tannic acid solution removed the smear layer more effectively than the regular cleansing agent.
NASA Astrophysics Data System (ADS)
Izatt, Susan D.; Choma, Michael A.; Israel, Steven; Wessells, Robert J.; Bodmer, Rolf; Izatt, Joseph A.
2005-03-01
Real time in vivo optical coherence tomography (OCT) imaging of the adult fruit fly Drosophila melanogaster heart using a newly designed OCT microscope allows accurate assessment of cardiac anatomy and function. D. melanogaster has been used extensively in genetic research for over a century, but in vivo evaluation of the heart has been limited by available imaging technology. The ability to assess phenotypic changes with micrometer-scale resolution noninvasively in genetic models such as D. melanogaster is needed in the advancing fields of developmental biology and genetics. We have developed a dedicated small animal OCT imaging system incorporating a state-of-the-art, real time OCT scanner integrated into a standard stereo zoom microscope which allows for simultaneous OCT and video imaging. System capabilities include A-scan, B-scan, and M-scan imaging as well as automated 3D volumetric acquisition and visualization. Transverse and sagittal B-mode scans of the four chambered D. melanogaster heart have been obtained with the OCT microscope and are consistent with detailed anatomical studies from the literature. Further analysis by M-mode scanning is currently under way to assess cardiac function as a function of age and sex by determination of shortening fraction and ejection fraction. These studies create control cardiac data on the wild type D. melanogaster, allowing subsequent evaluation of phenotypic cardiac changes in this model after regulated genetic mutation.
Cho, Won-Sang; Kim, Jeong Eun; Kang, Hyun-Seung; Ha, Eun Jin; Jung, Minwoong; Lee, Choonghee; Shin, Il Hyung; Kang, Uk
2017-04-01
Neuroendoscopy is useful for assessing status of perforators, parent arteries, and aneurysms beyond the straight line of microscopic view during aneurysm clipping. We aimed to evaluate the clinical usefulness of our endoscopic indocyanine green angiography (ICGA) system, which can simultaneously display visible light and indocyanine green fluorescent images. Surgical clipping of 16 unruptured aneurysms in 10 patients was performed via the keyhole approach. Using our endoscopic ICGA and commercial microscopic ICGA systems, we prospectively compared 10 targeted cerebral aneurysms at the posterior communicating (n = 4) and anterior choroidal (n = 6) arteries. Microscopic ICGA and endoscopic ICGA were feasible during surgery. Microscopic ICGA displayed 50% of branch orifices, 100% of branch trunks, and 20% of exact clip positions, whereas endoscopic ICGA showed 100% of these. Based on endoscopic ICGA findings such as incomplete clipping and compromise of parent arteries or branches, clips were repositioned in 2 cases, and additional clips were applied in 2 cases. Complete occlusion and residual neck states were achieved in 6 and 4 aneurysms after surgery. There were no neurologic deficits within 3 months after surgery except for frontalis palsy and anosmia in each patient. The endoscopic ICGA system with dual imaging of visible light and indocyanine green fluorescence was very useful for assessing geometry of aneurysms and surrounding vessels before clipping and for evaluating completeness of clip position after clipping. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Shrivastava, Prakash K.; Asthana, Rajesh; Roy, Sandip K.; Swain, Ashit K.; Dharwadkar, Amit
2012-07-01
The scientific study of quartz grains is a powerful tool in deciphering the depositional environment and mode of transportation of sediments, and ultimately the origin and classification of sediments. Surface microfeatures, angularity, chemical features, and grain-size analysis of quartz grains, collectively reveal the sedimentary and physicochemical processes that acted on the grains during different stages of their geological history. Here, we apply scanning electron microscopic (SEM) analysis to evaluating the sedimentary provenance, modes of transport, weathering characteristics, alteration, and sedimentary environment of selected detrital quartz grains from the peripheral part of two epi-shelf lakes (ESL-1 and ESL-2) of the Schirmacher Oasis of East Antarctica. Our study reveals that different styles of physical weathering, erosive signatures, and chemical precipitation variably affected these quartz grains before final deposition as lake sediments. Statistical analysis (central tendencies, sorting, skewness, and kurtosis) indicates that these quartz-bearing sediments are poorly sorted glaciofluvial sediments. Saltation and suspension seem to have been the two dominant modes of transportation, and chemical analysis of these sediments indicates a gneissic provenance.
Light microscopic study of periapical lesions associated with asymptomatic apical periodontitis.
Kabak, S L; Kabak, Y S; Anischenko, S L
2005-04-01
The purpose of the study has been to evaluate the degree of chronic inflammation in tissues surrounding the apex of the tooth root in patients with apical periodontitis in the remission phase. The material included 37 apical granulomas and radicular cysts obtained as a result of apiectomy, and 20 teeth which were removed together with the focus of the periapical inflammation. Routine histological techniques, as well as the immunofluorescent and immuno-chemical methods were used to examine the material. Despite the absence of clinical symptoms in 23 of 57 cases, the morphological signs of chronic inflammation were observed in the apical area of the tooth root. Morphological signs of viral invasion of epithelial and stromal cells in the radicular cyst wall were revealed in six cases. The presence of the virus of Herpes simplex I in epithelial cells (five cases) and adenoviral invasion (one case) was confirmed by immuno-fluorescent and immuno-chemical methods. Histological examination often reveals morphological signs of an active inflammatory process in the periapical tissues of patients treated during clinical remission. In our opinion, the presence of viruses in the epithelial cells of the radicular cyst may contribute to the persistence of the active stage of the inflammatory process.
NASA Astrophysics Data System (ADS)
Veerapandian, Murugan; Zhang, Linghe; Krishnamoorthy, Karthikeyan; Yun, Kyusik
2013-10-01
A comprehensive investigation of anti-bacterial properties of graphene oxide (GO) and ultraviolet (UV) irradiated GO nanosheets was carried out. Microscopic characterization revealed that the GO nanosheet-like structures had wavy features and wrinkles or thin grooves. Fundamental surface chemical states of GO nanosheets (before and after UV irradiation) were investigated using x-ray photoelectron spectroscopy and ultraviolet photoelectron spectroscopy. Minimum inhibitory concentration (MIC) results revealed that UV irradiated GO nanosheets have more pronounced anti-bacterial behavior than GO nanosheets and standard antibiotic, kanamycin. The MIC of UV irradiated GO nanosheets was 0.125 μg ml-1 for Escherichia coli and Salmonella typhimurium, 0.25 μg ml-1 for Bacillus subtilis and 0.5 μg ml-1 for Enterococcus faecalis, ensuring its potential as an anti-infective agent for controlling the growth of pathogenic bacteria. The minimum bactericidal concentration of normal GO nanosheets was determined to be two-fold higher than its corresponding MIC value, indicating promising bactericidal activity. The mechanism of anti-bacterial action was evaluated by measuring the enzymatic activity of β-d-galactosidase for the hydrolysis of o-nitrophenol-β-d-galactopyranoside.
NASA Astrophysics Data System (ADS)
Wang, Yabin; Liu, Zhong; Huang, Yudong; Qi, Yutai
2015-11-01
In the first part, a novel design route for metal protection against corrosion was proposed, and a class of triazinedithiolsilane compounds was conceived as protector for copper. The protective capability of the polymeric nanofilm, fabricated by self-assembling one representative (abbreviated as TESPA) of triazinedithiolsilane compounds onto copper surface, has been investigated and evaluated by electrochemical tests. The results show that the polymeric nanofilm significantly inhibits copper corrosion. This study, on the one hand, concentrates on the chemical composition of the TESPA polymeric nanofilm by means of X-ray photoelectron spectroscopy (XPS). The XPS results reveal that the chemical bonds between copper and TESPA monomers, three dimensional disulfide units and siloxane networks are responsible for the satisfactory protection of TESPA polymeric nanofilm against copper corrosion. On the other hand, scanning electron microscope (SEM) and energy-dispersive spectroscopy (EDS) are utilized to reveal the morphology and the uniformity of the TESPA polymeric nanofilm. The SEM-EDS results demonstrate that the copper surfaces are uniformly covered with TESPA self-assembled monolayer and the polymeric nanofilm. The TESPA-covered copper surfaces turn out to be smoother than that of the bare copper surface.
The ultrastructural features of the premalignant oral lesions.
Olinici, Doiniţa; Cotrutz, Carmen Elena; Mihali, Ciprian Valentin; Grecu, Vasile Bogdan; Botez, Emanuela Ana; Stoica, Laura; Onofrei, Pavel; Condurache, Oana; Dimitriu, Daniela Cristina
2018-01-01
Premalignant oral lesions are among the most important risk factors for the development of oral squamocellular carcinoma. Recent population studies indicate a significant rise in the prevalence of leukoplakia, erythroplakia/erythroleukoplakia, actinic cheilitis, submucous fibrosis and erosive lichen planus. Since standard histopathological examination has numerous limitations regarding the accurate appreciation of potential malignant transformation, the present study aims to aid these evaluations using the transmission electron microscopy (TEM) technique, which emphasizes ultrastructural changes pertaining to this pathology. Oral mucosa fragments collected from 43 patients that were clinically and histopathologically diagnosed with leukoplakia, erosive actinic cheilitis and erosive lichen planus have been processed through the classic technique for the examination using TEM and were examined using a Philips CM100 transmission electron microscope. The electron microscopy study has confirmed the histopathological diagnosis of the tissue samples examined using photonic microscopy and has furthermore revealed a series of ultrastructural details that on the one hand indicate the tendency for malignant transformation, and on the other reveal characteristic features of tumor development. All the details furnished by TEM complete the overall picture of morphological changes, specific to these lesions, indicating the importance of using these techniques in establishing both a correct diagnosis and prognosis.
Manickam, Cordelia; Dwivedi, Varun; Miller, Jayla; Papenfuss, Tracey; Renukaradhya, Gourapura J
2013-02-01
Porcine respiratory and reproductive syndrome (PRRS) is an economically important disease of pigs worldwide. Currently used PRRSV vaccines provide incomplete protection. Recently, we identified Mycobacterium tuberculosis whole cell lysate (Mtb WCL) as a potent mucosal adjuvant to modified live PRRSV vaccine (PRRS-MLV). In this study, pigs were unvaccinated or vaccinated with PRRS-MLV plus Mtb WCL, intranasally, and challenged with either homologous (strain VR2332) or virulent heterologous (strain MN184) PRRSV; subsequently, euthanized at three time points post-challenge to evaluate lung immune responses. Microscopic examination of lung sections revealed reduced disruption of the lung architecture and less of interstitial pneumonia in vaccinated, compared to unvaccinated MN184 challenged pigs. The restimulated lung and peripheral blood mononuclear cells revealed increased proliferation of CD8(+) lymphocytes, and in the lung homogenate increased secretion of nitric oxide was detected in vaccinated MN184 challenged pigs. In summary, the adjuvant effects of Mtb WCL to PRRS-MLV resulted in favorable anti-PRRSV immune microenvironment in the lungs to help better viral clearance.
Comparative evaluation of monocular augmented-reality display for surgical microscopes.
Rodriguez Palma, Santiago; Becker, Brian C; Lobes, Louis A; Riviere, Cameron N
2012-01-01
Medical augmented reality has undergone much development recently. However, there is a lack of studies quantitatively comparing the different display options available. This paper compares the effects of different graphical overlay systems in a simple micromanipulation task with "soft" visual servoing. We compared positioning accuracy in a real-time visually-guided task using Micron, an active handheld tremor-canceling microsurgical instrument, using three different displays: 2D screen, 3D screen, and microscope with monocular image injection. Tested with novices and an experienced vitreoretinal surgeon, display of virtual cues in the microscope via an augmented reality injection system significantly decreased 3D error (p < 0.05) compared to the 2D and 3D monitors when confounding factors such as magnification level were normalized.
NASA Astrophysics Data System (ADS)
Amanokura, Jin; Ono, Hiroshi; Hombo, Kyoko
2011-05-01
In order to obtain a high-speed copper chemical mechanical polishing (CMP) process for through silicon vias (TSV) application, we developed a new Cu CMP slurry through friction analysis of Cu reaction layer by an atomic force microscope (AFM) technique. A lateral modulation friction force microscope (LM-FFM) is able to measure the friction value properly giving a vibration to the layer. We evaluated the torsional displacement between the probe of the LM-FFM and the Cu reaction layer under a 5 nm vibration to cancel the shape effect of the Cu reaction layer. The developed Cu CMP slurry forms a frictionally easy-removable Cu reaction layer.
Low-power, low-cost urinalysis system with integrated dipstick evaluation and microscopic analysis.
Smith, Gennifer T; Li, Linkai; Zhu, Yue; Bowden, Audrey K
2018-06-21
We introduce a coupled dipstick and microscopy device for analyzing urine samples. The device is capable of accurately assessing urine dipstick results while simultaneously imaging the microscopic contents within the sample. We introduce a long working distance, cellphone-based microscope in combination with an oblique illumination scheme to accurately visualize and quantify particles within the urine sample. To facilitate accurate quantification, we couple the imaging set-up with a power-free filtration system. The proposed device is reusable, low-cost, and requires very little power. We show that results obtained with the proposed device and custom-built app are consistent with those obtained with the standard clinical protocol, suggesting the potential clinical utility of the device.
Wound Signaling: Monkeywrenching Macrophage Migration with Microscopes, Movies, and Math.
Galko, Michael J
2016-08-08
Drosophila hemocytes (blood cells) have emerged as a powerful system to image wound-induced inflammatory responses in vivo. New work reveals that layering mathematical modeling on top of imaging may be the most powerful tool yet for determining the properties of wound-induced signals. Copyright © 2016 Elsevier Ltd. All rights reserved.
Disseminated yeast (Order Saccharomycetales) infection in a Muscovy duckling (Cairina moschata)
Ravi, Madhu; Hill, Janet E.; Fernando, Champika; Wobeser, Gary
2016-01-01
A Muscovy duckling was presented for necropsy due to ongoing mortalities on a farm. Microscopic examination revealed multisystemic inflammatory lesions with intralesional and intracytoplasmic yeast-like organisms. We identified these agents as yeast belonging to the Order Saccharomycetales based on sequence data obtained from the ribosomal RNA operon. PMID:27807382
The Scanning Electron Microscope and the Archaeologist
ERIC Educational Resources Information Center
Ponting, Matthew
2004-01-01
Images from scanning electron microscopy are now quite common and they can be of great value in archaeology. Techniques such as secondary electron imaging, backscattered electron imaging and energy-dispersive x-ray analysis can reveal information such as the presence of weevils in grain in Roman Britain, the composition of Roman coins and the…
ERIC Educational Resources Information Center
Eyring, LeRoy
1980-01-01
Describes methods for using the high-resolution electron microscope in conjunction with other tools to reveal the identity and environment of atoms. Problems discussed include the ultimate structure of real crystalline solids including defect structure and the mechanisms of chemical reactions. (CS)
Demodicosis in an American bison.
Vestweber, J G; Ridley, R K; Nietfeld, J C; Wilkerson, M J
1999-01-01
An 18-month-old, male American bison (Bison bison) was presented with 7- to 9-mm size nodules periorbital, perineal, and on the ventral surface of the tail. Demodex spp. were identified from the exudate by microscopic examination. Examination 6 mo later revealed that the infestation had nearly cleared without treatment. Images Figure 1. Figure 2. PMID:10367158
Evolution of the Digital Society Reveals Balance between Viral and Mass Media Influence
NASA Astrophysics Data System (ADS)
Kleineberg, Kaj-Kolja; Boguñá, Marián
2014-07-01
Online social networks (OSNs) enable researchers to study the social universe at a previously unattainable scale. The worldwide impact and the necessity to sustain the rapid growth of OSNs emphasize the importance of unraveling the laws governing their evolution. Empirical results show that, unlike many real-world growing networked systems, OSNs follow an intricate path that includes a dynamical percolation transition. In light of these results, we present a quantitative two-parameter model that reproduces the entire topological evolution of a quasi-isolated OSN with unprecedented precision from the birth of the network. This allows us to precisely gauge the fundamental macroscopic and microscopic mechanisms involved. Our findings suggest that the coupling between the real preexisting underlying social structure, a viral spreading mechanism, and mass media influence govern the evolution of OSNs. The empirical validation of our model, on a macroscopic scale, reveals that virality is 4-5 times stronger than mass media influence and, on a microscopic scale, individuals have a higher subscription probability if invited by weaker social contacts, in agreement with the "strength of weak ties" paradigm.
The Mechanisms of Aberrant Protein Aggregation
NASA Astrophysics Data System (ADS)
Cohen, Samuel; Vendruscolo, Michele; Dobson, Chris; Knowles, Tuomas
2012-02-01
We discuss the development of a kinetic theory for understanding the aberrant loss of solubility of proteins. The failure to maintain protein solubility results often in the assembly of organized linear structures, commonly known as amyloid fibrils, the formation of which is associated with over 50 clinical disorders including Alzheimer's and Parkinson's diseases. A true microscopic understanding of the mechanisms that drive these aggregation processes has proved difficult to achieve. To address this challenge, we apply the methodologies of chemical kinetics to the biomolecular self-assembly pathways related to protein aggregation. We discuss the relevant master equation and analytical approaches to studying it. In particular, we derive the underlying rate laws in closed-form using a self-consistent solution scheme; the solutions that we obtain reveal scaling behaviors that are very generally present in systems of growing linear aggregates, and, moreover, provide a general route through which to relate experimental measurements to mechanistic information. We conclude by outlining a study of the aggregation of the Alzheimer's amyloid-beta peptide. The study identifies the dominant microscopic mechanism of aggregation and reveals previously unidentified therapeutic strategies.
Dynamic heterogeneity in an orientational glass
NASA Astrophysics Data System (ADS)
Caballero, Nirvana B.; Zuriaga, Mariano; Tamarit, Josep Lluís; Serra, Pablo
2017-11-01
The family of compounds CBrnCl4-n has been proven helpful in unraveling microscopic mechanisms responsible for glassy behavior. Some of the family members show translational ordered phases with minimal disorder which appears to reveal glassy features, thus deserving special attention in the search for universal glass anomalies. In this work, we studied CBrCl3 dynamics by performing extensive molecular dynamics simulations. Molecules of this compound perform reorientational discrete jumps, where the atoms exchange equivalent positions among each other revealing a cage-orientational jump motion fully comparable to the cage-rototranslational jump motion in supercooled liquids. Correlation times were calculated from rotational autocorrelation functions showing good agreement with previous reported dielectric results. From mean waiting and persistence times calculated directly from trajectory results, we are able to explain which microscopic mechanisms lead to characteristic times associated with α- and β-relaxation times measured experimentally. We found that two nonequivalent groups of molecules have a longer characteristic time than the other two nonequivalent groups, both of them belonging to the asymmetric unit of the monoclinic (C2/c) lattice.
Systemic microsporidiosis in inland bearded dragons (Pogona vitticeps).
Jacobson, E R; Green, D E; Undeen, A H; Cranfield, M; Vaughn, K L
1998-09-01
One laboratory-hatched and -reared inland bearded dragon (Pogona vitticeps) (No. 1) and two privately owned inland bearded dragons (Nos. 2 and 3) died, showing nonspecific signs of illness. Light microscopic examination of hematoxylin and eosin-stained tissue sections from lizard No. 1 revealed severe hepatic necrosis with clusters of light basophilic intracytoplasmic microorganisms packing and distending hepatocytes and free in areas of necrosis. Similar microorganisms were within cytoplasmic vacuoles in distended renal epithelial cells, pulmonary epithelial cells, gastric mucosal epithelial cells, enterocytes, and capillary endothelial cells and ventricular ependymal cells in the brain. In lizard Nos. 2 and 3, microorganisms of similar appearance were in macrophages in granulomatous inflammation in the colon, adrenal glands, and ovaries. The microorganism was gram positive and acid fast and had a small polar granule that stained using the periodic acid-Schiff reaction. Electron microscopic examination of deparaffinized liver of lizard No. 1 revealed merogonic and sporogonic stages of a protozoan compatible with members of the phylum Microspora. This report provides the first description of microsporidiosis in bearded dragons and is only the second report of this infection in a lizard.
NASA Astrophysics Data System (ADS)
Manigandan, K.; Srivatsan, T. S.; Vasudevan, V. K.; Tammana, D.; Poorganji, B.
2016-01-01
In this paper, the results of a study on microstructural influences on mechanical behavior of the high-strength alloy steel Tenax™ 310 are presented and discussed. Under the influence of fully reversed strain cycling, the stress response of this alloy steel revealed softening from the onset of deformation. Cyclic strain resistance exhibited a linear trend for the variation of both elastic strain amplitude with reversals-to-failure, and plastic strain amplitude with reversals-to-failure. Fracture morphology was essentially the same at the macroscopic level over the entire range of cyclic strain amplitudes examined. However, at the fine microscopic level, this high-strength alloy steel revealed fracture to be mixed-mode with features reminiscent of "locally" ductile and brittle mechanisms. The macroscopic mechanisms governing stress response at the fine microscopic level, resultant fatigue life, and final fracture behavior are presented and discussed in light of the mutually interactive influences of intrinsic microstructural effects, deformation characteristics of the microstructural constituents during fully reversed strain cycling, cyclic strain amplitude, and resultant response stress.
Lacap, Donnabella C; Smith, Gavin J D; Warren-Rhodes, Kimberley; Pointing, Stephen B
2005-07-01
Cyanobacterial mats were characterized from pools of 45-60 degrees C in near-neutral pH, low-sulphide geothermal springs in the Philippines. Mat structure did not vary with temperature. All mats possessed highly ordered layers of airspaces at both the macroscopic and microscopic level, and these appear to be an adaptation to a free-floating growth habit. Upper mat layers supported biomass with elevated carotenoid:chlorophyll a ratios and an as yet uncharacterized waxy layer on the dorsal surface. Microscopic examination revealed mats comprised a single Fischerella morphotype, with abundant heterocysts throughout mats at all temperatures. Molecular analysis of mat community structure only partly matched morphological identification. All samples supported greater 16S rDNA-defined diversity than morphology suggested, with a progressive loss in the number of genotypes with increasing temperature. Fischerella-like sequences were recovered from mats occurring at all temperatures, but some mats also yielded Oscillatoria-like sequences, although corresponding phenotypes were not observed. Phylogenetic analysis revealed that Fischerella-like sequences were most closely affiliated with Fischerella major and the Oscillatoria-like sequences with Oscillatoria amphigranulata.
Microstructural and thermal study of Al-Si-Mg/melon shell ash particulate composite
NASA Astrophysics Data System (ADS)
Abdulwahab, M.; Umaru, O. B.; Bawa, M. A.; Jibo, H. A.
The microstructural study via scanning electron microscope (SEM) and thermal study via differential scanning calorimetric (DSC) study of Al-7%Si-0.3Mg/melon shell ash particulate composite has been carried out. The melon shell ash was used in the production of MMC ranging from 5% to 20% at interval of 5% addition using stir casting method. The melon shell ash was characterized using X-ray fluorescent (XRF) that reveal the presence of CaO, SiO2, Al2O3, MgO, and TiO2 as major compounds. The composite was machined and subjected to heat treatment. Microstructural analyses of the composite produced were done using scanning electron microscope (SEM). The microstructure obtained reveals a dark ceramic (reinforcer) and white metallic phase. Equally, the 5 wt% DSC result gives better thermal conductivity than other proportions (10 wt%, 15 wt%, and 20 wt%). These results showed that an improved property of Al-Si-Mg alloy was achieved using melon shell ash particles as reinforcement up to a maximum of 20 wt% for microstructural and 5% wt DSC respectively.
Martínez, J; Martorell, J; Abarca, M L; Olvera, A; Ramis, A; Woods, L; Cheville, N; Juan-Sallés, C; Moya, A; Riera, A; Soto, S
2012-01-01
Between 2008 and 2009, three pet ferrets from different sources presented with acute episode of dyspnoea. Cytological examination of pleural exudates revealed severe purulent inflammation with abundant clusters of rod-shaped microorganisms with a clear surrounding halo. Treatment was ineffective and the ferrets died 2-5 days later. Two ferrets were subjected to necropsy examination, which revealed pyothorax, mediastinal lymphadenopathy and multiple white nodules (1-2mm) in the lungs. Microscopical examination showed multifocal necrotizing-pyogranulomatous pleuropneumonia and lymphadenitis with aggregates of encapsulated microorganisms, some of which were positively stained by periodic acid-Schiff and alcian blue. In-situ hybridization for Pneumocystis spp., Ziehl-Neelsen staining and immunohistochemistry for distemper, coronavirus and influenza antigen were negative in all cases. Electron microscopically, the bacteria were 2-3 μm long with a thick electron-lucent capsule. Microbiology from one ferret yielded a pure culture of gram-negative bacteria identified phenotypically as Pseudomonas luteola. This speciation was later confirmed by 16S RNA gene amplification. Copyright © 2011. Published by Elsevier Ltd.
Dynamic heterogeneity in an orientational glass.
Caballero, Nirvana B; Zuriaga, Mariano; Tamarit, Josep Lluís; Serra, Pablo
2017-11-14
The family of compounds CBr n Cl 4-n has been proven helpful in unraveling microscopic mechanisms responsible for glassy behavior. Some of the family members show translational ordered phases with minimal disorder which appears to reveal glassy features, thus deserving special attention in the search for universal glass anomalies. In this work, we studied CBrCl 3 dynamics by performing extensive molecular dynamics simulations. Molecules of this compound perform reorientational discrete jumps, where the atoms exchange equivalent positions among each other revealing a cage-orientational jump motion fully comparable to the cage-rototranslational jump motion in supercooled liquids. Correlation times were calculated from rotational autocorrelation functions showing good agreement with previous reported dielectric results. From mean waiting and persistence times calculated directly from trajectory results, we are able to explain which microscopic mechanisms lead to characteristic times associated with α- and β-relaxation times measured experimentally. We found that two nonequivalent groups of molecules have a longer characteristic time than the other two nonequivalent groups, both of them belonging to the asymmetric unit of the monoclinic (C2/c) lattice.
Harman, Francesca E; Corbett, Melanie C; Stevens, Julian D
2010-08-01
To evaluate differences in visual recovery after phacoemulsification with direct or tilted surgical microscope illumination using a macular photostress test. Western Eye Hospital, Imperial College Health Care National Health Service Trust, London, United Kingdom. This randomized double-masked controlled trial enrolled patients presenting to a daycare unit for single-eye cataract surgery. Inclusion criteria were no ocular pathology other than cataract, corneal keratometric astigmatism less than 1.50 diopters, intended target of emmetropia in the operated eye, and cataract grade 1 to 3 (Lens Opacification Classification System II). Exclusion criteria were an abnormal preoperative photostress test. Patients were randomized to have phacoemulsification with the operating microscope angled 15 degrees nasal to the fovea (study group) or with the operating microscope directly overhead around the optic disc region (control group). The same surgeon performed all phacoemulsification procedures using a standardized technique and topical anesthesia. Outcome measures were uncorrected (UDVA) and corrected (CDVA) distance visual acuity 10 minutes and 60 minutes postoperatively. In the 30 patients evaluated, the mean UDVA 10 minutes postoperatively was 0.40 logMAR +/- 0.26 (SD) in the study group and 0.72 +/- 0.36 logMAR in the control group (P<.01). The mean CDVA was 0.18 +/- 0.26 logMAR and 0.44 +/- 0.30 logMAR, respectively (P = .016). There was no significant between-group difference in acuity at 60 minutes. Tilting the microscope beam away from the fovea resulted in faster visual recovery and less macular photic stress. No author has a financial or proprietary interest in any material or method mentioned. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.