Sample records for microsoft windows application

  1. Windows Program For Driving The TDU-850 Printer

    NASA Technical Reports Server (NTRS)

    Parrish, Brett T.

    1995-01-01

    Program provides WYSIWYG compatibility between video display and printout. PDW is Microsoft Windows printer-driver computer program for use with Raytheon TDU-850 printer. Provides previously unavailable linkage between printer and IBM PC-compatible computers running Microsoft Windows. Enhances capabilities of Raytheon TDU-850 hardcopier by emulating all textual and graphical features normally supported by laser/ink-jet printers and makes printer compatible with any Microsoft Windows application. Also provides capabilities not found in laser/ink-jet printer drivers by providing certain Windows applications with ability to render high quality, true gray-scale photographic hardcopy on TDU-850. Written in C language.

  2. Scientific Data Analysis Toolkit: A Versatile Add-in to Microsoft Excel for Windows

    ERIC Educational Resources Information Center

    Halpern, Arthur M.; Frye, Stephen L.; Marzzacco, Charles J.

    2018-01-01

    Scientific Data Analysis Toolkit (SDAT) is a rigorous, versatile, and user-friendly data analysis add-in application for Microsoft Excel for Windows (PC). SDAT uses the familiar Excel environment to carry out most of the analytical tasks used in data analysis. It has been designed for student use in manipulating and analyzing data encountered in…

  3. EventSlider User Manual

    DTIC Science & Technology

    2016-09-01

    is a Windows Presentation Foundation (WPF) control developed using the .NET framework in Microsoft Visual Studio. As a WPF control, it can be used in...any WPF application as a graphical visual element. The purpose of the control is to visually display time-related events as vertical lines on a...available on the control. 15. SUBJECT TERMS Windows Presentation Foundation, WPF, control, C#, .NET framework, Microsoft Visual Studio 16. SECURITY

  4. A VBA Desktop Database for Proposal Processing at National Optical Astronomy Observatories

    NASA Astrophysics Data System (ADS)

    Brown, Christa L.

    National Optical Astronomy Observatories (NOAO) has developed a relational Microsoft Windows desktop database using Microsoft Access and the Microsoft Office programming language, Visual Basic for Applications (VBA). The database is used to track data relating to observing proposals from original receipt through the review process, scheduling, observing, and final statistical reporting. The database has automated proposal processing and distribution of information. It allows NOAO to collect and archive data so as to query and analyze information about our science programs in new ways.

  5. A personal digital assistant application (MobilDent) for dental fieldwork data collection, information management and database handling.

    PubMed

    Forsell, M; Häggström, M; Johansson, O; Sjögren, P

    2008-11-08

    To develop a personal digital assistant (PDA) application for oral health assessment fieldwork, including back-office and database systems (MobilDent). System design, construction and implementation of PDA, back-office and database systems. System requirements for MobilDent were collected, analysed and translated into system functions. User interfaces were implemented and system architecture was outlined. MobilDent was based on a platform with. NET (Microsoft) components, using an SQL Server 2005 (Microsoft) for data storage with Windows Mobile (Microsoft) operating system. The PDA devices were Dell Axim. System functions and user interfaces were specified for MobilDent. User interfaces for PDA, back-office and database systems were based on. NET programming. The PDA user interface was based on Windows suitable to a PDA display, whereas the back-office interface was designed for a normal-sized computer screen. A synchronisation module (MS Active Sync, Microsoft) was used to enable download of field data from PDA to the database. MobilDent is a feasible application for oral health assessment fieldwork, and the oral health assessment database may prove a valuable source for care planning, educational and research purposes. Further development of the MobilDent system will include wireless connectivity with download-on-demand technology.

  6. Extension of the PC version of VEPFIT with input and output routines running under Windows

    NASA Astrophysics Data System (ADS)

    Schut, H.; van Veen, A.

    1995-01-01

    The fitting program VEPFIT has been extended with applications running under the Microsoft-Windows environment facilitating the input and output of the VEPFIT fitting module. We have exploited the Microsoft-Windows graphical users interface by making use of dialog windows, scrollbars, command buttons, etc. The user communicates with the program simply by clicking and dragging with the mouse pointing device. Keyboard actions are limited to a minimum. Upon changing one or more input parameters the results of the modeling of the S-parameter and Ps fractions versus positron implantation energy are updated and displayed. This action can be considered as the first step in the fitting procedure upon which the user can decide to further adapt the input parameters or to forward these parameters as initial values to the fitting routine. The modeling step has proven to be helpful for designing positron beam experiments.

  7. MOST PROBABLE NUMBER (MPN) CALCULATOR Version 2.0 User and System Installation and Administration Manual

    EPA Science Inventory

    The new MPN Calculator is an easy-to-use stand alone Windows application built by Avineon, Inc. for the EPA. The calculator was built using Microsoft .NET (dot NET) version 3.5 SP1 (C#) and Windows Presentation Foundation technologies. The new calculator not only combines the mai...

  8. Microsoft's Vista: Guarantees People with Special Needs Access to Computers

    ERIC Educational Resources Information Center

    Williams, John M.

    2006-01-01

    In this article, the author discusses the accessibility features of Microsoft's Windows Vista. One of the most innovative aspects of Windows Vista is a new accessibility and automated testing model called Microsoft UI Automation, which reduces development costs not only for accessible and assistive technology (AT) developers, but also for…

  9. GeoWorks Considered. Part I: A GUI for the Rest of Us. Part II: Doing Windows Right.

    ERIC Educational Resources Information Center

    Flanders, Bruce; Lewis, Paul

    1991-01-01

    Describes GeoWorks, a new graphical user interface (GUI) that works on older, less powerful IBM PCs and compatibles. The PC/GEOS (PC/Graphical Environment Operating System) is explained, user friendliness is emphasized, comparisons are made to Microsoft Windows, and GeoWorks applications software is described. (LRW)

  10. An add-in implementation of the RESAMPLING syntax under Microsoft EXCEL.

    PubMed

    Meineke, I

    2000-10-01

    The RESAMPLING syntax defines a set of powerful commands, which allow the programming of probabilistic statistical models with few, easily memorized statements. This paper presents an implementation of the RESAMPLING syntax using Microsoft EXCEL with Microsoft WINDOWS(R) as a platform. Two examples are given to demonstrate typical applications of RESAMPLING in biomedicine. Details of the implementation with special emphasis on the programming environment are discussed at length. The add-in is available electronically to interested readers upon request. The use of the add-in facilitates numerical statistical analyses of data from within EXCEL in a comfortable way.

  11. Human Factors Feedback: Brain Acoustic Monitor

    DTIC Science & Technology

    2012-02-01

    Microsoft Office Excel .................................................................12  iv 4.  Conclusions 13  5.  References 15  Appendix A...Panasonic Toughbook system. †Toughbook is registered trademark of Panasonic Corporation. ‡Windows is a registered trademark of Microsoft Corporation. 4...was preloaded with Microsoft Windows XP service pack 2 OS. This OS is widely used on IBM-style personal computers, and the BAM system did not

  12. PCS: a pallet costing system for wood pallet manufacturers (version 1.0 for Windows®)

    Treesearch

    A. Jefferson, Jr. Palmer; Cynthia D. West; Bruce G. Hansen; Marshall S. White; Hal L. Mitchell

    2002-01-01

    The Pallet Costing System (PCS) is a computer-based, Microsoft Windows® application that computes the total and per-unit cost of manufacturing an order of wood pallets. Information about the manufacturing facility, along with the pallet-order requirements provided by the customer, is used in determining production cost. The major cost factors addressed by PCS...

  13. Using OpenOffice as a Portable Interface to JAVA-Based Applications

    NASA Astrophysics Data System (ADS)

    Comeau, T.; Garrett, B.; Richon, J.; Romelfanger, F.

    2004-07-01

    STScI previously used Microsoft Word and Microsoft Access, a Sybase ODBC driver, and the Adobe Acrobat PDF writer, along with a substantial amount of Visual Basic, to generate a variety of documents for the internal Space Telescope Grants Administration System (STGMS). While investigating an upgrade to Microsoft Office XP, we began considering alternatives, ultimately selecting an open source product, OpenOffice.org. This reduces the total number of products required to operate the internal STGMS system, simplifies the build system, and opens the possibility of moving to a non-Windows platform. We describe the experience of moving from Microsoft Office to OpenOffice.org, and our other internal uses of OpenOffice.org in our development environment.

  14. hi_dni_10km

    Science.gov Websites

    Microsoft Windows XP Version 5.1 (Build 2600) Service Pack 3; ESRI ArcCatalog 9.3.0.1770 en Monthly and @NREL.gov 10km Direct Normal Microsoft Windows XP Version 5.1 (Build 2600) Service Pack 3; ESRI ArcCatalog

  15. --No Title--

    Science.gov Websites

    } ItemDescription Microsoft Windows XP Version 5.1 (Build 2600) Service Pack 3; ESRI ArcCatalog 9.3.1.3000 en Annual Student RPP 303-384-7278 nick.grue@nrel.gov Microsoft Windows XP Version 5.1 (Build 2600) Service Pack 3

  16. LTCP 2D Graphical User Interface. Application Description and User's Guide

    NASA Technical Reports Server (NTRS)

    Ball, Robert; Navaz, Homayun K.

    1996-01-01

    A graphical user interface (GUI) written for NASA's LTCP (Liquid Thrust Chamber Performance) 2 dimensional computational fluid dynamic code is described. The GUI is written in C++ for a desktop personal computer running under a Microsoft Windows operating environment. Through the use of common and familiar dialog boxes, features, and tools, the user can easily and quickly create and modify input files for the LTCP code. In addition, old input files used with the LTCP code can be opened and modified using the GUI. The application is written in C++ for a desktop personal computer running under a Microsoft Windows operating environment. The program and its capabilities are presented, followed by a detailed description of each menu selection and the method of creating an input file for LTCP. A cross reference is included to help experienced users quickly find the variables which commonly need changes. Finally, the system requirements and installation instructions are provided.

  17. SNP_tools: A compact tool package for analysis and conversion of genotype data for MS-Excel

    PubMed Central

    Chen, Bowang; Wilkening, Stefan; Drechsel, Marion; Hemminki, Kari

    2009-01-01

    Background Single nucleotide polymorphism (SNP) genotyping is a major activity in biomedical research. Scientists prefer to have a facile access to the results which may require conversions between data formats. First hand SNP data is often entered in or saved in the MS-Excel format, but this software lacks genetic and epidemiological related functions. A general tool to do basic genetic and epidemiological analysis and data conversion for MS-Excel is needed. Findings The SNP_tools package is prepared as an add-in for MS-Excel. The code is written in Visual Basic for Application, embedded in the Microsoft Office package. This add-in is an easy to use tool for users with basic computer knowledge (and requirements for basic statistical analysis). Conclusion Our implementation for Microsoft Excel 2000-2007 in Microsoft Windows 2000, XP, Vista and Windows 7 beta can handle files in different formats and converts them into other formats. It is a free software. PMID:19852806

  18. SNP_tools: A compact tool package for analysis and conversion of genotype data for MS-Excel.

    PubMed

    Chen, Bowang; Wilkening, Stefan; Drechsel, Marion; Hemminki, Kari

    2009-10-23

    Single nucleotide polymorphism (SNP) genotyping is a major activity in biomedical research. Scientists prefer to have a facile access to the results which may require conversions between data formats. First hand SNP data is often entered in or saved in the MS-Excel format, but this software lacks genetic and epidemiological related functions. A general tool to do basic genetic and epidemiological analysis and data conversion for MS-Excel is needed. The SNP_tools package is prepared as an add-in for MS-Excel. The code is written in Visual Basic for Application, embedded in the Microsoft Office package. This add-in is an easy to use tool for users with basic computer knowledge (and requirements for basic statistical analysis). Our implementation for Microsoft Excel 2000-2007 in Microsoft Windows 2000, XP, Vista and Windows 7 beta can handle files in different formats and converts them into other formats. It is a free software.

  19. Integrating Existing Applications in Hypermedia Learning Material (General Issues & Experiences with OLE Technology).

    ERIC Educational Resources Information Center

    Borst Pauwels, H. W. J.; And Others

    The integration of existing applications in hypermedia environments is a promising approach towards more flexible and user-friendly hypermedia learning materials. A hypermedia courseware editor, called HyDE (Hypermedia Document Editor) was developed using Microsoft Windows TM OLE technology. OLE (object Linking and Embedding) stands for an…

  20. Windows 8: What Educators Need to Know

    ERIC Educational Resources Information Center

    Vedder, Richard G.

    2012-01-01

    In October 2012, Microsoft will release the commercial version of its next operating system, presently called "Windows 8." This version represents a significant departure from the past. Microsoft wants this operating system to meet user needs regardless of physical platform (e.g., desktop, notebook, tablet, mobile phone). As part of this mission,…

  1. Risk Assessment of the Naval Postgraduate School Gigabit Network

    DTIC Science & Technology

    2004-09-01

    Management Server (1) • Ras Server (1) • Remedy Server (1) • Samba Server(2) • SQL Servers (3) • Web Servers (3) • WINS Server (1) • Library...Server Bob Sharp INCA Windows 2000 Advanced Server NPGS Landesk SQL 2000 Alan Pires eagle Microsoft Windows 2000 Advanced Server EWS NPGS Landesk...Advanced Server Special Projects NPGS SQL Alan Pires MC01BDB Microsoft Windows 2000 Advanced Server Special Projects NPGS SQL 2000 Alan Pires

  2. Unobtrusive Social Network Data From Email

    DTIC Science & Technology

    2008-12-01

    PERSON Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 outlook archived files and stores that data into an SQL - database. Communication...Applications ( VBA ) program was installed on the personal computers (PC) of all participants, in the session window of their Microsoft Outlook. Details of

  3. GLobal Integrated Design Environment

    NASA Technical Reports Server (NTRS)

    Kunkel, Matthew; McGuire, Melissa; Smith, David A.; Gefert, Leon P.

    2011-01-01

    The GLobal Integrated Design Environment (GLIDE) is a collaborative engineering application built to resolve the design session issues of real-time passing of data between multiple discipline experts in a collaborative environment. Utilizing Web protocols and multiple programming languages, GLIDE allows engineers to use the applications to which they are accustomed in this case, Excel to send and receive datasets via the Internet to a database-driven Web server. Traditionally, a collaborative design session consists of one or more engineers representing each discipline meeting together in a single location. The discipline leads exchange parameters and iterate through their respective processes to converge on an acceptable dataset. In cases in which the engineers are unable to meet, their parameters are passed via e-mail, telephone, facsimile, or even postal mail. The result of this slow process of data exchange would elongate a design session to weeks or even months. While the iterative process remains in place, software can now exchange parameters securely and efficiently, while at the same time allowing for much more information about a design session to be made available. GLIDE is written in a compilation of several programming languages, including REALbasic, PHP, and Microsoft Visual Basic. GLIDE client installers are available to download for both Microsoft Windows and Macintosh systems. The GLIDE client software is compatible with Microsoft Excel 2000 or later on Windows systems, and with Microsoft Excel X or later on Macintosh systems. GLIDE follows the Client-Server paradigm, transferring encrypted and compressed data via standard Web protocols. Currently, the engineers use Excel as a front end to the GLIDE Client, as many of their custom tools run in Excel.

  4. Centralized Monitoring of the Microsoft Windows-based computers of the LHC Experiment Control Systems

    NASA Astrophysics Data System (ADS)

    Varela Rodriguez, F.

    2011-12-01

    The control system of each of the four major Experiments at the CERN Large Hadron Collider (LHC) is distributed over up to 160 computers running either Linux or Microsoft Windows. A quick response to abnormal situations of the computer infrastructure is crucial to maximize the physics usage. For this reason, a tool was developed to supervise, identify errors and troubleshoot such a large system. Although the monitoring of the performance of the Linux computers and their processes was available since the first versions of the tool, it is only recently that the software package has been extended to provide similar functionality for the nodes running Microsoft Windows as this platform is the most commonly used in the LHC detector control systems. In this paper, the architecture and the functionality of the Windows Management Instrumentation (WMI) client developed to provide centralized monitoring of the nodes running different flavour of the Microsoft platform, as well as the interface to the SCADA software of the control systems are presented. The tool is currently being commissioned by the Experiments and it has already proven to be very efficient optimize the running systems and to detect misbehaving processes or nodes.

  5. Human-Robot Interface Controller Usability for Mission Planning on the Move

    DTIC Science & Technology

    2012-11-01

    5 Figure 3. Microsoft Xbox 360 controller for Windows...6 Figure 5. Microsoft Trackball Explorer. .........................................................................................7 Figure 6...Xbox 360 Controller is a registered trademark of Microsoft Corporation. 4 3.2.1 HMMWV The HMMWV was equipped with a diesel engine

  6. Karst database development in Minnesota: Design and data assembly

    USGS Publications Warehouse

    Gao, Y.; Alexander, E.C.; Tipping, R.G.

    2005-01-01

    The Karst Feature Database (KFD) of Minnesota is a relational GIS-based Database Management System (DBMS). Previous karst feature datasets used inconsistent attributes to describe karst features in different areas of Minnesota. Existing metadata were modified and standardized to represent a comprehensive metadata for all the karst features in Minnesota. Microsoft Access 2000 and ArcView 3.2 were used to develop this working database. Existing county and sub-county karst feature datasets have been assembled into the KFD, which is capable of visualizing and analyzing the entire data set. By November 17 2002, 11,682 karst features were stored in the KFD of Minnesota. Data tables are stored in a Microsoft Access 2000 DBMS and linked to corresponding ArcView applications. The current KFD of Minnesota has been moved from a Windows NT server to a Windows 2000 Citrix server accessible to researchers and planners through networked interfaces. ?? Springer-Verlag 2005.

  7. Astronaut Office Scheduling System Software

    NASA Technical Reports Server (NTRS)

    Brown, Estevancio

    2010-01-01

    AOSS is a highly efficient scheduling application that uses various tools to schedule astronauts weekly appointment information. This program represents an integration of many technologies into a single application to facilitate schedule sharing and management. It is a Windows-based application developed in Visual Basic. Because the NASA standard office automation load environment is Microsoft-based, Visual Basic provides AO SS developers with the ability to interact with Windows collaboration components by accessing objects models from applications like Outlook and Excel. This also gives developers the ability to create newly customizable components that perform specialized tasks pertaining to scheduling reporting inside the application. With this capability, AOSS can perform various asynchronous tasks, such as gathering/ sending/ managing astronauts schedule information directly to their Outlook calendars at any time.

  8. The Case for an Open Data Model

    DTIC Science & Technology

    1998-08-01

    Microsoft Word, Pagemaker, and Framemaker , and the drawing programs MacDraw, Adobe Illustrator, and Microsoft PowerPoint, use their own proprietary...needs a custom word counting tool, since no utility could work in Word and other word processors. Framemaker for Windows does not have a word counting...supplied in 2 At least none that I could find in Framemaker 5.5 for Windows. Another problem with

  9. A Tale of Two Observing Systems: Interoperability in the World of Microsoft Windows

    NASA Astrophysics Data System (ADS)

    Babin, B. L.; Hu, L.

    2008-12-01

    Louisiana Universities Marine Consortium's (LUMCON) and Dauphin Island Sea Lab's (DISL) Environmental Monitoring System provide a unified coastal ocean observing system. These two systems are mirrored to maintain autonomy while offering an integrated data sharing environment. Both systems collect data via Campbell Scientific Data loggers, store the data in Microsoft SQL servers, and disseminate the data in real- time on the World Wide Web via Microsoft Internet Information Servers and Active Server Pages (ASP). The utilization of Microsoft Windows technologies presented many challenges to these observing systems as open source tools for interoperability grow. The current open source tools often require the installation of additional software. In order to make data available through common standards formats, "home grown" software has been developed. One example of this is the development of software to generate xml files for transmission to the National Data Buoy Center (NDBC). OOSTethys partners develop, test and implement easy-to-use, open-source, OGC-compliant software., and have created a working prototype of networked, semantically interoperable, real-time data systems. Partnering with OOSTethys, we are developing a cookbook to implement OGC web services. The implementation will be written in ASP, will run in a Microsoft operating system environment, and will serve data via Sensor Observation Services (SOS). This cookbook will give observing systems running Microsoft Windows the tools to easily participate in the Open Geospatial Consortium (OGC) Oceans Interoperability Experiment (OCEANS IE).

  10. Micrometeoroid and Orbital Debris (MMOD) Shield Ballistic Limit Analysis Program

    NASA Technical Reports Server (NTRS)

    Ryan, Shannon

    2013-01-01

    This software implements penetration limit equations for common micrometeoroid and orbital debris (MMOD) shield configurations, windows, and thermal protection systems. Allowable MMOD risk is formulated in terms of the probability of penetration (PNP) of the spacecraft pressure hull. For calculating the risk, spacecraft geometry models, mission profiles, debris environment models, and penetration limit equations for installed shielding configurations are required. Risk assessment software such as NASA's BUMPERII is used to calculate mission PNP; however, they are unsuitable for use in shield design and preliminary analysis studies. The software defines a single equation for the design and performance evaluation of common MMOD shielding configurations, windows, and thermal protection systems, along with a description of their validity range and guidelines for their application. Recommendations are based on preliminary reviews of fundamental assumptions, and accuracy in predicting experimental impact test results. The software is programmed in Visual Basic for Applications for installation as a simple add-in for Microsoft Excel. The user is directed to a graphical user interface (GUI) that requires user inputs and provides solutions directly in Microsoft Excel workbooks.

  11. ScreenRecorder: A Utility for Creating Screenshot Video Using Only Original Equipment Manufacturer (OEM) Software on Microsoft Windows Systems

    DTIC Science & Technology

    2015-01-01

    class within Microsoft Visual Studio . 2 It has been tested on and is compatible with Microsoft Vista, 7, and 8 and Visual Studio Express 2008...the ScreenRecorder utility assumes a basic understanding of compiling and running C++ code within Microsoft Visual Studio . This report does not...of Microsoft Visual Studio , the ScreenRecorder utility was developed as a C++ class that can be compiled as a library (static or dynamic) to be

  12. Challenging Google, Microsoft Unveils a Search Tool for Scholarly Articles

    ERIC Educational Resources Information Center

    Carlson, Scott

    2006-01-01

    Microsoft has introduced a new search tool to help people find scholarly articles online. The service, which includes journal articles from prominent academic societies and publishers, puts Microsoft in direct competition with Google Scholar. The new free search tool, which should work on most Web browsers, is called Windows Live Academic Search…

  13. WinSCP for Windows File Transfers | High-Performance Computing | NREL

    Science.gov Websites

    WinSCP for Windows File Transfers WinSCP for Windows File Transfers WinSCP for can used to securely transfer files between your local computer running Microsoft Windows and a remote computer running Linux

  14. CO2calc: A User-Friendly Seawater Carbon Calculator for Windows, Mac OS X, and iOS (iPhone)

    USGS Publications Warehouse

    Robbins, L.L.; Hansen, M.E.; Kleypas, J.A.; Meylan, S.C.

    2010-01-01

    A user-friendly, stand-alone application for the calculation of carbonate system parameters was developed by the U.S. Geological Survey Florida Shelf Ecosystems Response to Climate Change Project in response to its Ocean Acidification Task. The application, by Mark Hansen and Lisa Robbins, USGS St. Petersburg, FL, Joanie Kleypas, NCAR, Boulder, CO, and Stephan Meylan, Jacobs Technology, St. Petersburg, FL, is intended as a follow-on to CO2SYS, originally developed by Lewis and Wallace (1998) and later modified for Microsoft Excel? by Denis Pierrot (Pierrot and others, 2006). Besides eliminating the need for using Microsoft Excel on the host system, CO2calc offers several improvements on CO2SYS, including: An improved graphical user interface for data entry and results Additional calculations of air-sea CO2 fluxes (for surface water calculations) The ability to tag data with sample name, comments, date, time, and latitude/longitude The ability to use the system time and date and latitude/ longitude (automatic retrieval of latitude and longitude available on iPhone? 3, 3GS, 4, and Windows? hosts with an attached National Marine Electronics Association (NMEA)-enabled GPS) The ability to process multiple files in a batch processing mode An option to save sample information, data input, and calculated results as a comma-separated value (CSV) file for use with Microsoft Excel, ArcGIS,? or other applications An option to export points with geographic coordinates as a KMZ file for viewing and editing in Google EarthTM

  15. The Microsoft Biology Foundation Applications for High-Throughput Sequencing

    PubMed Central

    Mercer, S.

    2010-01-01

    w9-2 The need for reusable libraries of bioinformatics functions has been recognized for many years and a number of language-specific toolkits have been constructed. Such toolkits have served as valuable nucleation points for the community, promoting the sharing of code and establishing standards. The majority of DNA sequencing machines and many other standard pieces of lab equipment are controlled by PCs using Windows, and a Microsoft genomics toolkit would enable initial processing and quality control to happen closer to the instrumentation and provide opportunities for added-value services within core facilities. The Microsoft Biology Foundation (MBF) is an open source software library, freely available for both commercial and academic use, available as an early-stage betafrom mbf.codeplex.com. This presentation will describe the structure and goals of MBF and demonstrate some of its uses.

  16. Windows Terminal Servers Orchestration

    NASA Astrophysics Data System (ADS)

    Bukowiec, Sebastian; Gaspar, Ricardo; Smith, Tim

    2017-10-01

    Windows Terminal Servers provide application gateways for various parts of the CERN accelerator complex, used by hundreds of CERN users every day. The combination of new tools such as Puppet, HAProxy and Microsoft System Center suite enable automation of provisioning workflows to provide a terminal server infrastructure that can scale up and down in an automated manner. The orchestration does not only reduce the time and effort necessary to deploy new instances, but also facilitates operations such as patching, analysis and recreation of compromised nodes as well as catering for workload peaks.

  17. Experience with ActiveX control for simple channel access

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Timossi, C.; Nishimura, H.; McDonald, J.

    2003-05-15

    Accelerator control system applications at Berkeley Lab's Advanced Light Source (ALS) are typically deployed on operator consoles running Microsoft Windows 2000 and utilize EPICS[2]channel access for data access. In an effort to accommodate the wide variety of Windows based development tools and developers with little experience in network programming, ActiveX controls have been deployed on the operator stations. Use of ActiveX controls for use in the accelerator control environment has been presented previously[1]. Here we report on some of our experiences with the use and development of these controls.

  18. NaturalReader: A New Generation Text Reader

    ERIC Educational Resources Information Center

    Flood, Jacqueline

    2007-01-01

    NaturalReader (http://www.naturalreaders.com/) is a new generation text reader, which means that it reads any machine readable text using synthesized speech without having to copy and paste the selected text into the NaturalReader application window. It installs a toolbar directly into all of the Microsoft Office[TM] programs and uses a mini-board…

  19. A mobile field-work data collection system for the wireless era of health surveillance.

    PubMed

    Forsell, Marianne; Sjögren, Petteri; Renard, Matthew; Johansson, Olle

    2011-03-01

    In many countries or regions the capacity of health care resources is below the needs of the population and new approaches for health surveillance are needed. Innovative projects, utilizing wireless communication technology, contribute to reliable methods for field-work data collection and reporting to databases. The objective was to describe a new version of a wireless IT-support system for field-work data collection and administration. The system requirements were drawn from the design objective and translated to system functions. The system architecture was based on fieldwork experiences and administrative requirements. The Smartphone devices were HTC Touch Diamond2s, while the system was based on a platform with Microsoft .NET components, and a SQL Server 2005 with Microsoft Windows Server 2003 operating system. The user interfaces were based on .NET programming, and Microsoft Windows Mobile operating system. A synchronization module enabled download of field data to the database, via a General Packet Radio Services (GPRS) to a Local Area Network (LAN) interface. The field-workers considered the here-described applications user-friendly and almost self-instructing. The office administrators considered that the back-office interface facilitated retrieval of health reports and invoice distribution. The current IT-support system facilitates short lead times from fieldwork data registration to analysis, and is suitable for various applications. The advantages of wireless technology, and paper-free data administration need to be increasingly emphasized in development programs, in order to facilitate reliable and transparent use of limited resources.

  20. Access to Microsoft Windows 95 for Persons with Low Vision: An Overview.

    ERIC Educational Resources Information Center

    Shragai, Y.

    1995-01-01

    This article examines Windows 95, pointing out differences and improvements from Windows 3.1 for persons with low vision. Windows 95 is seen as providing substantially greater accessibility than Windows 3.1, though the graphical user interface may still pose serious problems for some users with low vision. (DB)

  1. HPC in a HEP lab: lessons learned from setting up cost-effective HPC clusters

    NASA Astrophysics Data System (ADS)

    Husejko, Michal; Agtzidis, Ioannis; Baehler, Pierre; Dul, Tadeusz; Evans, John; Himyr, Nils; Meinhard, Helge

    2015-12-01

    In this paper we present our findings gathered during the evaluation and testing of Windows Server High-Performance Computing (Windows HPC) in view of potentially using it as a production HPC system for engineering applications. The Windows HPC package, an extension of Microsofts Windows Server product, provides all essential interfaces, utilities and management functionality for creating, operating and monitoring a Windows-based HPC cluster infrastructure. The evaluation and test phase was focused on verifying the functionalities of Windows HPC, its performance, support of commercial tools and the integration with the users work environment. We describe constraints imposed by the way the CERN Data Centre is operated, licensing for engineering tools and scalability and behaviour of the HPC engineering applications used at CERN. We will present an initial set of requirements, which were created based on the above constraints and requests from the CERN engineering user community. We will explain how we have configured Windows HPC clusters to provide job scheduling functionalities required to support the CERN engineering user community, quality of service, user- and project-based priorities, and fair access to limited resources. Finally, we will present several performance tests we carried out to verify Windows HPC performance and scalability.

  2. An interactive program for computer-aided map design, display, and query: EMAPKGS2

    USGS Publications Warehouse

    Pouch, G.W.

    1997-01-01

    EMAPKGS2 is a user-friendly, PC-based electronic mapping tool for use in hydrogeologic exploration and appraisal. EMAPKGS2 allows the analyst to construct maps interactively from data stored in a relational database, perform point-oriented spatial queries such as locating all wells within a specified radius, perform geographic overlays, and export the data to other programs for further analysis. EMAPKGS2 runs under Microsoft?? Windows??? 3.1 and compatible operating systems. EMAPKGS2 is a public domain program available from the Kansas Geological Survey. EMAPKGS2 is the centerpiece of WHEAT, the Windows-based Hydrogeologic Exploration and Appraisal Toolkit, a suite of user-friendly Microsoft?? Windows??? programs for natural resource exploration and management. The principal goals in development of WHEAT have been ease of use, hardware independence, low cost, and end-user extensibility. WHEAT'S native data format is a Microsoft?? Access?? database. WHEAT stores a feature's geographic coordinates as attributes so they can be accessed easily by the user. The WHEAT programs are designed to be used in conjunction with other Microsoft?? Windows??? software to allow the natural resource scientist to perform work easily and effectively. WHEAT and EMAPKGS have been used at several of Kansas' Groundwater Management Districts and the Kansas Geological Survey on groundwater management operations, groundwater modeling projects, and geologic exploration projects. ?? 1997 Elsevier Science Ltd.

  3. Music@Microsoft.Windows: Composing Ambience

    ERIC Educational Resources Information Center

    Rickert, Thomas

    2010-01-01

    It is well known, of course, that all Windows versions except for 3.1 have a brief (four to six second) piece of music indicating that Windows is booted and ready for use. While the music may indicate Windows has booted, it bears no immediately discernable relation to the various uses we might actually put Windows to--working, gaming,…

  4. Bird Vision System

    NASA Technical Reports Server (NTRS)

    2008-01-01

    The Bird Vision system is a multicamera photogrammerty software application that runs on a Microsoft Windows XP platform and was developed at Kennedy Space Center by ASRC Aerospace. This software system collects data about the locations of birds within a volume centered on the Space Shuttle and transmits it in real time to the laptop computer of a test director in the Launch Control Center (LCC) Firing Room.

  5. User's guide to UGRS: the Ultimate Grading and Remanufacturing System (version 5.0).

    Treesearch

    John Moody; Charles J. Gatchell; Elizabeth S. Walker; Powsiri Klinkhachorn

    1998-01-01

    The Ultimate Grading and Remanufacturing System (UGRS) is the latest generation of advanced computer programs for lumber grading. It is designed to be a training and research tool that allows grading of lumber according to 1998 NHLA rules and remanufacturing for maximum dollar value. A 32-bit application that runs under all Microsoft Windows operating systems, UGRS...

  6. Program Processes Thermocouple Readings

    NASA Technical Reports Server (NTRS)

    Quave, Christine A.; Nail, William, III

    1995-01-01

    Digital Signal Processor for Thermocouples (DART) computer program implements precise and fast method of converting voltage to temperature for large-temperature-range thermocouple applications. Written using LabVIEW software. DART available only as object code for use on Macintosh II FX or higher-series computers running System 7.0 or later and IBM PC-series and compatible computers running Microsoft Windows 3.1. Macintosh version of DART (SSC-00032) requires LabVIEW 2.2.1 or 3.0 for execution. IBM PC version (SSC-00031) requires LabVIEW 3.0 for Windows 3.1. LabVIEW software product of National Instruments and not included with program.

  7. Low-cost real-time 3D PC distributed-interactive-simulation (DIS) application for C4I

    NASA Astrophysics Data System (ADS)

    Gonthier, David L.; Veron, Harry

    1998-04-01

    A 3D Distributed Interactive Simulation (DIS) application was developed and demonstrated in a PC environment. The application is capable of running in the stealth mode or as a player which includes battlefield simulations, such as ModSAF. PCs can be clustered together, but not necessarily collocated, to run a simulation or training exercise on their own. A 3D perspective view of the battlefield is displayed that includes terrain, trees, buildings and other objects supported by the DIS application. Screen update rates of 15 to 20 frames per second have been achieved with fully lit and textured scenes thus providing high quality and fast graphics. A complete PC system can be configured for under $2,500. The software runs under Windows95 and WindowsNT. It is written in C++ and uses a commercial API called RenderWare for 3D rendering. The software uses Microsoft Foundation classes and Microsoft DirectPlay for joystick input. The RenderWare libraries enhance the performance through optimization for MMX and the Pentium Pro processor. The RenderWare and the Righteous 3D graphics board from Orchid Technologies with an advertised rendering rate of up to 2 million texture mapped triangles per second. A low-cost PC DIS simulator that can partake in a real-time collaborative simulation with other platforms is thus achieved.

  8. RDNAnalyzer: A tool for DNA secondary structure prediction and sequence analysis.

    PubMed

    Afzal, Muhammad; Shahid, Ahmad Ali; Shehzadi, Abida; Nadeem, Shahid; Husnain, Tayyab

    2012-01-01

    RDNAnalyzer is an innovative computer based tool designed for DNA secondary structure prediction and sequence analysis. It can randomly generate the DNA sequence or user can upload the sequences of their own interest in RAW format. It uses and extends the Nussinov dynamic programming algorithm and has various application for the sequence analysis. It predicts the DNA secondary structure and base pairings. It also provides the tools for routinely performed sequence analysis by the biological scientists such as DNA replication, reverse compliment generation, transcription, translation, sequence specific information as total number of nucleotide bases, ATGC base contents along with their respective percentages and sequence cleaner. RDNAnalyzer is a unique tool developed in Microsoft Visual Studio 2008 using Microsoft Visual C# and Windows Presentation Foundation and provides user friendly environment for sequence analysis. It is freely available. http://www.cemb.edu.pk/sw.html RDNAnalyzer - Random DNA Analyser, GUI - Graphical user interface, XAML - Extensible Application Markup Language.

  9. Using Microsoft Access XP: A How-To-Do-It Manual for Librarians. How-To-Do-It Manuals for Librarians, Number 120.

    ERIC Educational Resources Information Center

    Butler, E. Sonny; Napier, Timothy R.

    This manual is designed to assist librarians in programming unique database applications that meet specific library needs. Chapter 1 goes over the basic functions of working with Windows, describes terms such as multitasking, and shows how to use the menu and tool bars. Chapter 2 covers the basics, defines some useful terms, and presents the steps…

  10. Software for Real-Time Analysis of Subsonic Test Shot Accuracy

    DTIC Science & Technology

    2014-03-01

    used the C++ programming language, the Open Source Computer Vision ( OpenCV ®) software library, and Microsoft Windows® Application Programming...video for comparison through OpenCV image analysis tools. Based on the comparison, the software then computed the coordinates of each shot relative to...DWB researchers wanted to use the Open Source Computer Vision ( OpenCV ) software library for capturing and analyzing frames of video. OpenCV contains

  11. WinHPC System | High-Performance Computing | NREL

    Science.gov Websites

    System WinHPC System NREL's WinHPC system is a computing cluster running the Microsoft Windows operating system. It allows users to run jobs requiring a Windows environment such as ANSYS and MATLAB

  12. Design considerations of CareWindows, a Windows 3.0-based graphical front end to a Medical Information Management System using a pass-through-requester architecture.

    PubMed Central

    Ward, R. E.; Purves, T.; Feldman, M.; Schiffman, R. M.; Barry, S.; Christner, M.; Kipa, G.; McCarthy, B. D.; Stiphout, R.

    1991-01-01

    The Care Windows development project demonstrated the feasibility of an approach designed to add the benefits of an event-driven, graphically-oriented user interface to an existing Medical Information Management System (MIMS) without overstepping economic and logistic constraints. The design solution selected for the Care Windows project incorporates three important design features: (1) the effective de-coupling of severs from requesters, permitting the use of an extensive pre-existing library of MIMS servers, (2) the off-loading of program control functions of the requesters to the workstation processor, reducing the load per transaction on central resources and permitting the use of object-oriented development environments available for microcomputers, (3) the selection of a low end, GUI-capable workstation consisting of a PC-compatible personal computer running Microsoft Windows 3.0, and (4) the development of a highly layered, modular workstation application, permitting the development of interchangeable modules to insure portability and adaptability. PMID:1807665

  13. Integrated Approach to User Account Management

    NASA Technical Reports Server (NTRS)

    Kesselman, Glenn; Smith, William

    2007-01-01

    IT environments consist of both Windows and other platforms. Providing user account management for this model has become increasingly diffi cult. If Microsoft#s Active Directory could be enhanced to extend a W indows identity for authentication services for Unix, Linux, Java and Macintosh systems, then an integrated approach to user account manag ement could be realized.

  14. PC vs. Mac--Which Way Should You Go?

    ERIC Educational Resources Information Center

    Wodarz, Nan

    1997-01-01

    Outlines the factors in hardware, software, and administration to consider in developing specifications for choosing a computer operating system. Compares Microsoft Windows 95/NT that runs on PC/Intel-based systems and System 7.5 that runs on the Apple-based systems. Lists reasons why the Microsoft platform clearly stands above the Apple platform.…

  15. Knowledge Glyphs: Visualization Theory Development to Support C2 Practice

    DTIC Science & Technology

    2006-03-01

    interface’s graphic structure (Calder and Linton, 2003). "• ’Glyphs’ as components of a typographical set (Microsoft Typography Standards). "* ’DataGlyphs...MOOTW) factors MIL STD 2525’s symbology set was designed for application in the context of geospatial representations - i.e., geographical maps. It is...the visual elements used to portray discrete entities. In a conventional windowing environment, such entities are likely to be graphically portrayed

  16. MAT - MULTI-ATTRIBUTE TASK BATTERY FOR HUMAN OPERATOR WORKLOAD AND STRATEGIC BEHAVIOR RESEARCH

    NASA Technical Reports Server (NTRS)

    Comstock, J. R.

    1994-01-01

    MAT, a Multi-Attribute Task battery, gives the researcher the capability of performing multi-task workload and performance experiments. The battery provides a benchmark set of tasks for use in a wide range of laboratory studies of operator performance and workload. MAT incorporates tasks analogous to activities that aircraft crew members perform in flight, while providing a high degree of experiment control, performance data on each subtask, and freedom to use non-pilot test subjects. The MAT battery primary display is composed of four separate task windows which are as follows: a monitoring task window which includes gauges and warning lights, a tracking task window for the demands of manual control, a communication task window to simulate air traffic control communications, and a resource management task window which permits maintaining target levels on a fuel management task. In addition, a scheduling task window gives the researcher information about future task demands. The battery also provides the option of manual or automated control of tasks. The task generates performance data for each subtask. The task battery may be paused and onscreen workload rating scales presented to the subject. The MAT battery was designed to use a serially linked second computer to generate the voice messages for the Communications task. The MATREMX program and support files, which are included in the MAT package, were designed to work with the Heath Voice Card (Model HV-2000, available through the Heath Company, Benton Harbor, Michigan 49022); however, the MATREMX program and support files may easily be modified to work with other voice synthesizer or digitizer cards. The MAT battery task computer may also be used independent of the voice computer if no computer synthesized voice messages are desired or if some other method of presenting auditory messages is devised. MAT is written in QuickBasic and assembly language for IBM PC series and compatible computers running MS-DOS. The code in MAT is written for Microsoft QuickBasic 4.5 and Microsoft Macro Assembler 5.1. This package requires a joystick and EGA or VGA color graphics. An 80286, 386, or 486 processor machine is highly recommended. The standard distribution medium for MAT is a 5.25 inch 360K MS-DOS format diskette. The files are compressed using the PKZIP file compression utility. PKUNZIP is included on the distribution diskette. MAT was developed in 1992. IBM PC is a registered trademark of International Business Machines. MS-DOS, Microsoft QuickBasic, and Microsoft Macro Assembler are registered trademarks of Microsoft Corporation. PKZIP and PKUNZIP are registered trademarks of PKWare, Inc.

  17. Judo strategy. The competitive dynamics of Internet time.

    PubMed

    Yoffie, D B; Cusumano, M A

    1999-01-01

    Competition on the Internet is creating fierce battles between industry giants and small-scale start-ups. Smart start-ups can avoid those conflicts by moving quickly to uncontested ground and, when that's no longer possible, turning dominant players' strengths against them. The authors call this competitive approach judo strategy. They use the Netscape-Microsoft battles to illustrate the three main principles of judo strategy: rapid movement, flexibility, and leverage. In the early part of the browser wars, for instance, Netscape applied the principle of rapid movement by being the first company to offer a free stand-alone browser. This allowed Netscape to build market share fast and to set the market standard. Flexibility became a critical factor later in the browser wars. In December 1995, when Microsoft announced that it would "embrace and extend" competitors' Internet successes, Netscape failed to give way in the face of superior strength. Instead it squared off against Microsoft and even turned down numerous opportunities to craft deep partnerships with other companies. The result was that Netscape lost deal after deal when competing with Microsoft for common distribution channels. Netscape applied the principle of leverage by using Microsoft's strengths against it. Taking advantage of Microsoft's determination to convert the world to Windows or Windows NT, Netscape made its software compatible with existing UNIX systems. While it is true that these principles can't replace basic execution, say the authors, without speed, flexibility, and leverage, very few companies can compete successfully on Internet time.

  18. NCWin — A Component Object Model (COM) for processing and visualizing NetCDF data

    USGS Publications Warehouse

    Liu, Jinxun; Chen, J.M.; Price, D.T.; Liu, S.

    2005-01-01

    NetCDF (Network Common Data Form) is a data sharing protocol and library that is commonly used in large-scale atmospheric and environmental data archiving and modeling. The NetCDF tool described here, named NCWin and coded with Borland C + + Builder, was built as a standard executable as well as a COM (component object model) for the Microsoft Windows environment. COM is a powerful technology that enhances the reuse of applications (as components). Environmental model developers from different modeling environments, such as Python, JAVA, VISUAL FORTRAN, VISUAL BASIC, VISUAL C + +, and DELPHI, can reuse NCWin in their models to read, write and visualize NetCDF data. Some Windows applications, such as ArcGIS and Microsoft PowerPoint, can also call NCWin within the application. NCWin has three major components: 1) The data conversion part is designed to convert binary raw data to and from NetCDF data. It can process six data types (unsigned char, signed char, short, int, float, double) and three spatial data formats (BIP, BIL, BSQ); 2) The visualization part is designed for displaying grid map series (playing forward or backward) with simple map legend, and displaying temporal trend curves for data on individual map pixels; and 3) The modeling interface is designed for environmental model development by which a set of integrated NetCDF functions is provided for processing NetCDF data. To demonstrate that the NCWin can easily extend the functions of some current GIS software and the Office applications, examples of calling NCWin within ArcGIS and MS PowerPoint for showing NetCDF map animations are given.

  19. Surviving sepsis--a 3D integrative educational simulator.

    PubMed

    Ježek, Filip; Tribula, Martin; Kulhánek, Tomáš; Mateják, Marek; Privitzer, Pavol; Šilar, Jan; Kofránek, Jiří; Lhotská, Lenka

    2015-08-01

    Computer technology offers greater educational possibilities, notably simulation and virtual reality. This paper presents a technology which serves to integrate multiple modalities, namely 3D virtual reality, node-based simulator, Physiomodel explorer and explanatory physiological simulators employing Modelica language and Unity3D platform. This emerging tool chain should allow the authors to concentrate more on educational content instead of application development. The technology is demonstrated through Surviving sepsis educational scenario, targeted on Microsoft Windows Store platform.

  20. RDNAnalyzer: A tool for DNA secondary structure prediction and sequence analysis

    PubMed Central

    Afzal, Muhammad; Shahid, Ahmad Ali; Shehzadi, Abida; Nadeem, Shahid; Husnain, Tayyab

    2012-01-01

    RDNAnalyzer is an innovative computer based tool designed for DNA secondary structure prediction and sequence analysis. It can randomly generate the DNA sequence or user can upload the sequences of their own interest in RAW format. It uses and extends the Nussinov dynamic programming algorithm and has various application for the sequence analysis. It predicts the DNA secondary structure and base pairings. It also provides the tools for routinely performed sequence analysis by the biological scientists such as DNA replication, reverse compliment generation, transcription, translation, sequence specific information as total number of nucleotide bases, ATGC base contents along with their respective percentages and sequence cleaner. RDNAnalyzer is a unique tool developed in Microsoft Visual Studio 2008 using Microsoft Visual C# and Windows Presentation Foundation and provides user friendly environment for sequence analysis. It is freely available. Availability http://www.cemb.edu.pk/sw.html Abbreviations RDNAnalyzer - Random DNA Analyser, GUI - Graphical user interface, XAML - Extensible Application Markup Language. PMID:23055611

  1. Acceptance of direct physician access to a computer-based patient record in a managed care setting.

    PubMed

    Dewey, J B; Manning, P; Brandt, S

    1993-01-01

    Kaiser Permanente Mid-Atlantic States has developed a fully integrated outpatient information system which currently runs on an IBM ES9000 on a VM platform written in MUMPS. The applications include Lab, Radiology, Transcription, Appointments. Pharmacy, Encounter tracking, Hospitalizations, Referrals, Phone Advice, Pap tracking, Problem list, Immunization tracking, and Patient demographics. They are department specific and require input and output from a dumb terminal. We have developed a physician's work station to access this information using PC compatible computers running Microsoft Windows and a custom Microsoft Visual Basic 2.0 environment which draws from these 14 applications giving the physician a comprehensive view of all electronic medical records. Through rapid prototyping, voluntary participation, formal training and gradual implementation we have created an enthusiastic response. 95% of our physician PC users access the system each month. The use ranges from 0.2 to 3.0 screens of data viewed per patient visit. This response continues to drive the process toward still greater user acceptance and further practice enhancement.

  2. P43-S Computational Biology Applications Suite for High-Performance Computing (BioHPC.net)

    PubMed Central

    Pillardy, J.

    2007-01-01

    One of the challenges of high-performance computing (HPC) is user accessibility. At the Cornell University Computational Biology Service Unit, which is also a Microsoft HPC institute, we have developed a computational biology application suite that allows researchers from biological laboratories to submit their jobs to the parallel cluster through an easy-to-use Web interface. Through this system, we are providing users with popular bioinformatics tools including BLAST, HMMER, InterproScan, and MrBayes. The system is flexible and can be easily customized to include other software. It is also scalable; the installation on our servers currently processes approximately 8500 job submissions per year, many of them requiring massively parallel computations. It also has a built-in user management system, which can limit software and/or database access to specified users. TAIR, the major database of the plant model organism Arabidopsis, and SGN, the international tomato genome database, are both using our system for storage and data analysis. The system consists of a Web server running the interface (ASP.NET C#), Microsoft SQL server (ADO.NET), compute cluster running Microsoft Windows, ftp server, and file server. Users can interact with their jobs and data via a Web browser, ftp, or e-mail. The interface is accessible at http://cbsuapps.tc.cornell.edu/.

  3. Wireless network interface energy consumption implications of popular streaming formats

    NASA Astrophysics Data System (ADS)

    Chandra, Surendar

    2001-12-01

    With the proliferation of mobile streaming multimedia, available battery capacity constrains the end-user experience. Since streaming applications tend to be long running, wireless network interface card's (WNIC) energy consumption is particularly an acute problem. In this work, we explore the WNIC energy consumption implications of popular multimedia streaming formats from Microsoft (Windows media), Real (Real media) and Apple (Quick Time). We investigate the energy consumption under varying stream bandwidth and network loss rates. We also explore history-based client-side strategies to reduce the energy consumed by transitioning the WNICs to a lower power consuming sleep state. We show that Microsoft media tends to transmit packets at regular intervals; streams optimized for 28.8 Kbps can save over 80% in energy consumption with 2% data loss. A high bandwidth stream (768 Kbps) can still save 57% in energy consumption with less than 0.3% data loss. For high bandwidth streams, Microsoft media exploits network-level packet fragmentation, which can lead to excessive packet loss (and wasted energy) in a lossy network. Real stream packets tend to be sent closer to each other, especially at higher bandwidths. Quicktime packets sometimes arrive in quick succession; most likely an application level fragmentation mechanism. Such packets are harder to predict at the network level without understanding the packet semantics.

  4. A Windows application for computing standardized mortality ratios and standardized incidence ratios in cohort studies based on calculation of exact person-years at risk.

    PubMed

    Geiss, Karla; Meyer, Martin

    2013-09-01

    Standardized mortality ratios and standardized incidence ratios are widely used in cohort studies to compare mortality or incidence in a study population to that in the general population on a age-time-specific basis, but their computation is not included in standard statistical software packages. Here we present a user-friendly Microsoft Windows program for computing standardized mortality ratios and standardized incidence ratios based on calculation of exact person-years at risk stratified by sex, age and calendar time. The program offers flexible import of different file formats for input data and easy handling of general population reference rate tables, such as mortality or incidence tables exported from cancer registry databases. The application of the program is illustrated with two examples using empirical data from the Bavarian Cancer Registry. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  5. Software For Design And Analysis Of Tanks And Cylindrical Shells

    NASA Technical Reports Server (NTRS)

    Luz, Paul L.; Graham, Jerry B.

    1995-01-01

    Skin-stringer Tank Analysis Spreadsheet System (STASS) computer program developed for use as preliminary design software tool that enables quick-turnaround design and analysis of structural domes and cylindrical barrel sections in propellant tanks or other cylindrical shells. Determines minimum required skin thicknesses for domes and cylindrical shells to withstand material failure due to applied pressures (ullage and/or hydrostatic) and runs buckling analyses on cylindrical shells and skin-stringers. Implemented as workbook program, using Microsoft Excel v4.0 on Macintosh II. Also implemented using Microsoft Excel v4.0 for Microsoft Windows v3.1 IBM PC.

  6. Development of a Simple Image Processing Application that Makes Abdominopelvic Tumor Visible on Positron Emission Tomography/Computed Tomography Image.

    PubMed

    Pandey, Anil Kumar; Saroha, Kartik; Sharma, Param Dev; Patel, Chetan; Bal, Chandrashekhar; Kumar, Rakesh

    2017-01-01

    In this study, we have developed a simple image processing application in MATLAB that uses suprathreshold stochastic resonance (SSR) and helps the user to visualize abdominopelvic tumor on the exported prediuretic positron emission tomography/computed tomography (PET/CT) images. A brainstorming session was conducted for requirement analysis for the program. It was decided that program should load the screen captured PET/CT images and then produces output images in a window with a slider control that should enable the user to view the best image that visualizes the tumor, if present. The program was implemented on personal computer using Microsoft Windows and MATLAB R2013b. The program has option for the user to select the input image. For the selected image, it displays output images generated using SSR in a separate window having a slider control. The slider control enables the user to view images and select one which seems to provide the best visualization of the area(s) of interest. The developed application enables the user to select, process, and view output images in the process of utilizing SSR to detect the presence of abdominopelvic tumor on prediuretic PET/CT image.

  7. Creating a Parallel Version of VisIt for Microsoft Windows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whitlock, B J; Biagas, K S; Rawson, P L

    2011-12-07

    VisIt is a popular, free interactive parallel visualization and analysis tool for scientific data. Users can quickly generate visualizations from their data, animate them through time, manipulate them, and save the resulting images or movies for presentations. VisIt was designed from the ground up to work on many scales of computers from modest desktops up to massively parallel clusters. VisIt is comprised of a set of cooperating programs. All programs can be run locally or in client/server mode in which some run locally and some run remotely on compute clusters. The VisIt program most able to harness today's computing powermore » is the VisIt compute engine. The compute engine is responsible for reading simulation data from disk, processing it, and sending results or images back to the VisIt viewer program. In a parallel environment, the compute engine runs several processes, coordinating using the Message Passing Interface (MPI) library. Each MPI process reads some subset of the scientific data and filters the data in various ways to create useful visualizations. By using MPI, VisIt has been able to scale well into the thousands of processors on large computers such as dawn and graph at LLNL. The advent of multicore CPU's has made parallelism the 'new' way to achieve increasing performance. With today's computers having at least 2 cores and in many cases up to 8 and beyond, it is more important than ever to deploy parallel software that can use that computing power not only on clusters but also on the desktop. We have created a parallel version of VisIt for Windows that uses Microsoft's MPI implementation (MSMPI) to process data in parallel on the Windows desktop as well as on a Windows HPC cluster running Microsoft Windows Server 2008. Initial desktop parallel support for Windows was deployed in VisIt 2.4.0. Windows HPC cluster support has been completed and will appear in the VisIt 2.5.0 release. We plan to continue supporting parallel VisIt on Windows so our users will be able to take full advantage of their multicore resources.« less

  8. Computer Architecture's Changing Role in Rebooting Computing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeBenedictis, Erik P.

    In this paper, Windows 95 started the Wintel era, in which Microsoft Windows running on Intel x86 microprocessors dominated the computer industry and changed the world. Retaining the x86 instruction set across many generations let users buy new and more capable microprocessors without having to buy software to work with new architectures.

  9. Schools Facing the Expiration of Windows XP

    ERIC Educational Resources Information Center

    Cavanagh, Sean

    2013-01-01

    Microsoft's plans to end support for Windows XP, believed to be the dominant computer operating system in K-12 education, could pose big technological and financial challenges for districts nationwide--issues that many school systems have yet to confront. The giant software company has made it clear for years that it plans to stop supporting XP…

  10. Computer Architecture's Changing Role in Rebooting Computing

    DOE PAGES

    DeBenedictis, Erik P.

    2017-04-26

    In this paper, Windows 95 started the Wintel era, in which Microsoft Windows running on Intel x86 microprocessors dominated the computer industry and changed the world. Retaining the x86 instruction set across many generations let users buy new and more capable microprocessors without having to buy software to work with new architectures.

  11. Configuration Tool for the Trusted Computing Exemplar Project

    DTIC Science & Technology

    2009-12-01

    languages were examined: Microsoft .NET [8], Apple Cocoa (Objective-C) [9], wxPython [10], and Java [11]. Since every language has its pros and...languages using the criteria described above. Based on the developer’s limited experience and knowledge of Microsoft .NET and Apple Cocoa (Objective...became a tabbed panel within a separate window panel. Figure 9 depicts this evolution of the conceptual design. In Figure 9, the table column

  12. Web GIS in practice X: a Microsoft Kinect natural user interface for Google Earth navigation

    PubMed Central

    2011-01-01

    This paper covers the use of depth sensors such as Microsoft Kinect and ASUS Xtion to provide a natural user interface (NUI) for controlling 3-D (three-dimensional) virtual globes such as Google Earth (including its Street View mode), Bing Maps 3D, and NASA World Wind. The paper introduces the Microsoft Kinect device, briefly describing how it works (the underlying technology by PrimeSense), as well as its market uptake and application potential beyond its original intended purpose as a home entertainment and video game controller. The different software drivers available for connecting the Kinect device to a PC (Personal Computer) are also covered, and their comparative pros and cons briefly discussed. We survey a number of approaches and application examples for controlling 3-D virtual globes using the Kinect sensor, then describe Kinoogle, a Kinect interface for natural interaction with Google Earth, developed by students at Texas A&M University. Readers interested in trying out the application on their own hardware can download a Zip archive (included with the manuscript as additional files 1, 2, &3) that contains a 'Kinnogle installation package for Windows PCs'. Finally, we discuss some usability aspects of Kinoogle and similar NUIs for controlling 3-D virtual globes (including possible future improvements), and propose a number of unique, practical 'use scenarios' where such NUIs could prove useful in navigating a 3-D virtual globe, compared to conventional mouse/3-D mouse and keyboard-based interfaces. PMID:21791054

  13. Web GIS in practice X: a Microsoft Kinect natural user interface for Google Earth navigation.

    PubMed

    Boulos, Maged N Kamel; Blanchard, Bryan J; Walker, Cory; Montero, Julio; Tripathy, Aalap; Gutierrez-Osuna, Ricardo

    2011-07-26

    This paper covers the use of depth sensors such as Microsoft Kinect and ASUS Xtion to provide a natural user interface (NUI) for controlling 3-D (three-dimensional) virtual globes such as Google Earth (including its Street View mode), Bing Maps 3D, and NASA World Wind. The paper introduces the Microsoft Kinect device, briefly describing how it works (the underlying technology by PrimeSense), as well as its market uptake and application potential beyond its original intended purpose as a home entertainment and video game controller. The different software drivers available for connecting the Kinect device to a PC (Personal Computer) are also covered, and their comparative pros and cons briefly discussed. We survey a number of approaches and application examples for controlling 3-D virtual globes using the Kinect sensor, then describe Kinoogle, a Kinect interface for natural interaction with Google Earth, developed by students at Texas A&M University. Readers interested in trying out the application on their own hardware can download a Zip archive (included with the manuscript as additional files 1, 2, &3) that contains a 'Kinnogle installation package for Windows PCs'. Finally, we discuss some usability aspects of Kinoogle and similar NUIs for controlling 3-D virtual globes (including possible future improvements), and propose a number of unique, practical 'use scenarios' where such NUIs could prove useful in navigating a 3-D virtual globe, compared to conventional mouse/3-D mouse and keyboard-based interfaces.

  14. Software Intensive Systems

    DTIC Science & Technology

    2006-07-01

    Architect, Developer and Platform Evangelism • Microsoft Dynamic Systems Initiative-- John Wilson, Architect Windows Management • Windows Lifecycle...Presentations • Aegis--Reuben Pitts & CDR John Ailes, Program Executive Office, Integrated Warfare Systems • Long Term Mine Reconnaissance (LMRS)--CAPT...Paul Imes • Joint Tactical Radio System (JTRS)--Richard North, JPEO JTRS & Leonard Schiavone , MITRE • Single Integrated Air Picture (SIAP)--CAPT

  15. The battle between Unix and Windows NT.

    PubMed

    Anderson, H J

    1997-02-01

    For more than a decade, Unix has been the dominant back-end operating system in health care. But that prominent position is being challenged by Windows NT, touted by its developer, Microsoft Corp., as the operating system of the future. CIOs and others are attempting to figure out which system is the best choice in the long run.

  16. SBexpert users guide (version 1.0): a knowledge-based decision-support system for spruce beetle management.

    Treesearch

    Keith M. Reynolds; Edward H. Holsten; Richard A. Werner

    1994-01-01

    SBexpert version 1.0 is a knowledge-based decision-support system for spruce beetle (Dendroctonus rutipennis (Kby.)) management developed for use in Microsoft Windows with the KnowledgePro Windows development language. The SBexpert users guide provides detailed instructions on the use of all SBexpert features. SBexpert has four main topics (...

  17. Configuration Tool Prototype for the Trusted Computing Exemplar Project

    DTIC Science & Technology

    2009-12-01

    languages were examined: Microsoft .NET [8], Apple Cocoa (Objective-C) [9], wxPython [10], and Java [11]. Since every language has its pros and...languages using the criteria described above. Based on the developer’s limited experience and knowledge of Microsoft .NET and Apple Cocoa (Objective...a tabbed panel within a separate window panel. Figure 9 depicts this evolution of the conceptual design. In Figure 9, the table column headers are

  18. Survey of Network Visualization Tools

    DTIC Science & Technology

    2007-12-01

    Dimensionality • 2D Comments: Deployment Type: • Components for tool building • Standalone Tool OS: • Windows Extensibility • ActiveX ...Visual Basic Comments: Interoperability Daisy is fully compliant with Microsoft’s ActiveX , therefore, other Windows based programs can...other functions that improve analytic decision making. Available in ActiveX , C++, Java, and .NET editions. • Tom Sawyer Visualization: Enables you to

  19. SBexpert users guide (version 2.0): a knowledge-based decision-support system for spruce beetle management.

    Treesearch

    Keith M. Reynolds; Edward H. Holsten

    1997-01-01

    SBexpert version 2.0 is a knowledge-based decision-support system for spruce beetle (Dendroctonus rufipennis (Kby.)) management developed for use in Microsoft (MS) Windows with the KnowledgePro Windows development language. Version 2.0 is a significant enhancement of version 1.0. The SBexpert users guide provides detailed instructions on the use of...

  20. UIMX: A User Interface Management System For Scientific Computing With X Windows

    NASA Astrophysics Data System (ADS)

    Foody, Michael

    1989-09-01

    Applications with iconic user interfaces, (for example, interfaces with pulldown menus, radio buttons, and scroll bars), such as those found on Apple's Macintosh computer and the IBM PC under Microsoft's Presentation Manager, have become very popular, and for good reason. They are much easier to use than applications with traditional keyboard-oriented interfaces, so training costs are much lower and just about anyone can use them. They are standardized between applications, so once you learn one application you are well along the way to learning another. The use of one reinforces the common elements between applications of the interface, and, as a result, you remember how to use them longer. Finally, for the developer, their support costs can be much lower because of their ease of use.

  1. MARVIN: a medical research application framework based on open source software.

    PubMed

    Rudolph, Tobias; Puls, Marc; Anderegg, Christoph; Ebert, Lars; Broehan, Martina; Rudin, Adrian; Kowal, Jens

    2008-08-01

    This paper describes the open source framework MARVIN for rapid application development in the field of biomedical and clinical research. MARVIN applications consist of modules that can be plugged together in order to provide the functionality required for a specific experimental scenario. Application modules work on a common patient database that is used to store and organize medical data as well as derived data. MARVIN provides a flexible input/output system with support for many file formats including DICOM, various 2D image formats and surface mesh data. Furthermore, it implements an advanced visualization system and interfaces to a wide range of 3D tracking hardware. Since it uses only highly portable libraries, MARVIN applications run on Unix/Linux, Mac OS X and Microsoft Windows.

  2. Performance Measurements for the Microsoft Kinect Skeleton

    DTIC Science & Technology

    2012-03-01

    Information Inter- faces and Presentation]: User Interfaces—Input devices and strate- gies; 1 INTRODUCTION The Microsoft Kinect for Xbox 360 (“Kinect...these values. 2 MEASUREMENTS We conducted our tests on a machine configured with Windows 7 Ultimate (Service Pack 1) equipped with two Intel Core2...test. We tested with one , two, and three users present, although only two skeletons may be tracked. 2.1 Range We need to know how close and how far a

  3. Approaches in highly parameterized inversion—PEST++ Version 3, a Parameter ESTimation and uncertainty analysis software suite optimized for large environmental models

    USGS Publications Warehouse

    Welter, David E.; White, Jeremy T.; Hunt, Randall J.; Doherty, John E.

    2015-09-18

    The PEST++ Version 3 software suite can be compiled for Microsoft Windows®4 and Linux®5 operating systems; the source code is available in a Microsoft Visual Studio®6 2013 solution; Linux Makefiles are also provided. PEST++ Version 3 continues to build a foundation for an open-source framework capable of producing robust and efficient parameter estimation tools for large environmental models.

  4. Calibration of the Total and Static Pressure Transducers in the DSTO Transonic Wind Tunnel

    DTIC Science & Technology

    2010-08-01

    handled by the ActiveX control MSCOMM32.OCX which is not part of the Microsoft Windows operating system. It is, however, included as part of the...implemented new measures to register ActiveX controls in its Windows suite of operating systems, which has made the above file obsolete and it could no...longer be used if the Windows operating system were updated. If this is the case, then the new version of ActiveX control files can be installed using

  5. Visual Sample Plan Version 7.0 User's Guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matzke, Brett D.; Newburn, Lisa LN; Hathaway, John E.

    2014-03-01

    User's guide for VSP 7.0 This user's guide describes Visual Sample Plan (VSP) Version 7.0 and provides instructions for using the software. VSP selects the appropriate number and location of environmental samples to ensure that the results of statistical tests performed to provide input to risk decisions have the required confidence and performance. VSP Version 7.0 provides sample-size equations or algorithms needed by specific statistical tests appropriate for specific environmental sampling objectives. It also provides data quality assessment and statistical analysis functions to support evaluation of the data and determine whether the data support decisions regarding sites suspected of contamination.more » The easy-to-use program is highly visual and graphic. VSP runs on personal computers with Microsoft Windows operating systems (XP, Vista, Windows 7, and Windows 8). Designed primarily for project managers and users without expertise in statistics, VSP is applicable to two- and three-dimensional populations to be sampled (e.g., rooms and buildings, surface soil, a defined layer of subsurface soil, water bodies, and other similar applications) for studies of environmental quality. VSP is also applicable for designing sampling plans for assessing chem/rad/bio threat and hazard identification within rooms and buildings, and for designing geophysical surveys for unexploded ordnance (UXO) identification.« less

  6. Microsoft, libraries and open source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2010-04-26

    We are finally starting to see the early signs of transformation inscholarly publishing. The innovations we've been expecting for years areslowly being adopted, but we can also expect the pace of change toaccelerate in the coming 3 to 5 years. At the same time, many of ritualsand artifacts of the scholarly communication lifecycle are still rooted ina centuries-old model.  What are the primary goals of scholarlycommunication, and what will be the future role of librarians in thatcycle?  What are the obstacles in information flow (many of our owndesign) that can be removed?Is the library profession moving fast enough to staymore » ahead of the curve...or are we ever going to be struggling to keep up? With the advent of thedata deluge, all-XML workflows, the semantic Web, cloud servicesand increasingly intelligent mobile devices - what are the implicationsfor libraries, archivists, publishers, scholarly societies as well asindividual researchers and scholars? The opportunities are many - butcapitalizing on this ever-evolving landscape will require significantchanges to our field, changes that we are not currently well-positioned toenact. This talk will map the current scholarly communication landscape -highlighting recent exciting developments, and will focus on therepercussions and some specific recommendations for the broader field ofinformation management.About the speaker:Alex Wade is the Director for Scholarly Communication within Microsoft'sExternal Research division, where he oversees several projects related toresearcher productivity tools, semantic information capture, and theinteroperability of information systems. Alex holds a Bachelor's degree inPhilosophy from U.C. Berkeley, and a Masters of Librarianship degree fromthe University of Washington.During his career at Microsoft, Alex has managed the corporate search andtaxonomy management services; has shipped a SharePoint-based document andworkflow management solution for Sarbanes-Oxley compliance; and served asSenior Program Manager for Windows Search in Windows Vista and Windows 7.Prior to joining Microsoft, Alex held Systems Librarian, EngineeringLibrarian, Philosophy Librarian, and technical library positions at theUniversity of Washington, the University of Michigan, and U.C. Berkeley.Web: http://research.microsoft.com/en-us/people/awade/ « less

  7. State Cancer Profiles

    MedlinePlus

    ... the site again. The following web browsers and operating systems are sufficiently secure and advanced. These version numbers ... also acceptable. Microsoft Internet Explorer 7, if your operating system is Windows Vista or later. No version of ...

  8. PWL 1.0 Personal WaveLab: an object-oriented workbench for seismogram analysis on Windows systems

    NASA Astrophysics Data System (ADS)

    Bono, Andrea; Badiali, Lucio

    2005-02-01

    Personal WaveLab 1.0 wants to be the starting point for an ex novo development of seismic time-series analysis procedures for Windows-based personal computers. Our objective is two-fold. Firstly, being itself a stand-alone application, it allows to do "basic" digital or digitised seismic waveform analysis. Secondly, thanks to its architectural characteristics it can be the basis for the development of more complex and power featured applications. An expanded version of PWL, called SisPick!, is currently in use at the Istituto Nazionale di Geofisica e Vulcanologia (Italian Institute of Geophysics and Volcanology) for real-time monitoring with purposes of Civil Protection. This means that about 90 users tested the application for more than 1 year, making its features more robust and efficient. SisPick! was also employed in the United Nations Nyragongo Project, in Congo, and during the Stromboli emergency in summer of 2002. The main appeals of the application package are: ease of use, object-oriented design, good computational speed, minimal need of disk space and the complete absence of third-party developed components (including ActiveX). Windows environment spares the user scripting or complex interaction with the system. The system is in constant development to answer the needs and suggestions of its users. Microsoft Visual Basic 6 source code, installation package, test data sets and documentation are available at no cost.

  9. MAX: Multiplatform Applications for XAFS

    NASA Astrophysics Data System (ADS)

    Alain, Michalowicz; Jacques, Moscovici; Diane, Muller-Bouvet; Karine, Provost

    2009-11-01

    MAX is a new EXAFS and XANES analysis package, replacing our old "EXAFS pour le Mac" software suite. The major improvement is the ability to work with strictly the same code, compiled at once for Microsoft Windows, Apple MacOSX and LINUX systems, justifying the title "Multiplatform Applications for XAFS". It is organized as four modules: ABSORBIX (X-ray absorbance and fluorescence self-absorption calculations), CHEROKEE (EXAFS and XANES data treatment), ROUNDMIDNIGHT (EXAFS modeling and fit) and CRYSTALFFREV (from crystal structures and molecular modeling to FEFF EXAFS and XANES theoretical calculations). Most features developed in "EXAFS pour le Mac" are still available, but with much improvements in the user's interface, data treatment algorithms and new functionalities.

  10. A DSS for sustainable development and environmental protection of agricultural regions.

    PubMed

    Manos, Basil D; Papathanasiou, Jason; Bournaris, Thomas; Voudouris, Kostas

    2010-05-01

    This paper presents a decision support system (DSS) for sustainable development and environmental protection of agricultural regions developed in the framework of the Interreg-Archimed project entitled WaterMap (development and utilization of vulnerability maps for the monitoring and management of groundwater resources in the ARCHIMED areas). Its aim is to optimize the production plan of an agricultural region taking in account the available resources, the environmental parameters, and the vulnerability map of the region. The DSS is based on an optimization multicriteria model. The spatial integration of vulnerability maps in the DSS enables regional authorities to design policies for optimal agricultural development and groundwater protection from the agricultural land uses. The DSS can further be used to simulate different scenarios and policies by the local stakeholders due to changes on different social, economic, and environmental parameters. In this way, they can achieve alternative production plans and agricultural land uses as well as to estimate economic, social, and environmental impacts of different policies. The DSS is computerized and supported by a set of relational databases. The corresponding software has been developed in a Microsoft Windows XP platform, using Microsoft Visual Basic, Microsoft Access, and the LINDO library. For demonstration reasons, the paper includes an application of the DSS in a region of Northern Greece.

  11. Multimedia proceedings of the 10th Office Information Technology Conference

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hudson, B.

    1993-09-10

    The CD contains the handouts for all the speakers, demo software from Apple, Adobe, Microsoft, and Zylabs, and video movies of the keynote speakers. Adobe Acrobat is used to provide full-fidelity retrieval of the speakers` slides and Apple`s Quicktime for Macintosh and Windows is used for video playback. ZyIndex is included for Windows users to provide a full-text search engine for selected documents. There are separately labelled installation and operating instructions for Macintosh and Windows users and some general materials common to both sets of users.

  12. Development and Implementation of GPS Correlator Structures in MATLAB and Simulink with Focus on SDR Applications: Implementation of a Standard GPS Correlator Architecture (Baseline) Implementation of the MIT Quicksynch Sparse Algorithm Development and Implementation of Parallel Circular Correlator Constructs

    DTIC Science & Technology

    2014-05-01

    software is available for a wide variety of operating systems , including Unix, FreeBSD, Linux, Solaris, Novell NetWare, OS X, Microsoft Windows, OS/2, TPF...Word for Xenix systems . Subsequent versions were later written for several other platforms including IBM PCs running DOS (1983), Apple Macintosh ...this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204

  13. The evolution of the ISOLDE control system

    NASA Astrophysics Data System (ADS)

    Jonsson, O. C.; Catherall, R.; Deloose, I.; Drumm, P.; Evensen, A. H. M.; Gase, K.; Focker, G. J.; Fowler, A.; Kugler, E.; Lettry, J.; Olesen, G.; Ravn, H. L.; Isolde Collaboration

    The ISOLDE on-line mass separator facility is operating on a Personal Computer based control system since spring 1992. Front End Computers accessing the hardware are controlled from consoles running Microsoft Windows ™ through a Novell NetWare4 ™ local area network. The control system is transparently integrated in the CERN wide office network and makes heavy use of the CERN standard office application programs to control and to document the running of the ISOLDE isotope separators. This paper recalls the architecture of the control system, shows its recent developments and gives some examples of its graphical user interface.

  14. The evolution of the ISOLDE control system

    NASA Astrophysics Data System (ADS)

    Jonsson, O. C.; Catherall, R.; Deloose, I.; Evensen, A. H. M.; Gase, K.; Focker, G. J.; Fowler, A.; Kugler, E.; Lettry, J.; Olesen, G.; Ravn, H. L.; Drumm, P.

    1996-04-01

    The ISOLDE on-line mass separator facility is operating on a Personal Computer based control system since spring 1992. Front End Computers accessing the hardware are controlled from consoles running Microsoft Windows® through a Novell NetWare4® local area network. The control system is transparently integrated in the CERN wide office network and makes heavy use of the CERN standard office application programs to control and to document the running of the ISOLDE isotope separators. This paper recalls the architecture of the control system, shows its recent developments and gives some examples of its graphical user interface.

  15. PETRO.CALC.PLOT, Microsoft Excel macros to aid petrologic interpretation

    USGS Publications Warehouse

    Sidder, G.B.

    1994-01-01

    PETRO.CALC.PLOT is a package of macros which normalizes whole-rock oxide data to 100%, calculates the cation percentages and molecular proportions used for normative mineral calculations, computes the apices for ternary diagrams, determines sums and ratios of specific elements of petrologic interest, and plots 33 X-Y graphs and five ternary diagrams. PETRO.CALC.PLOT also may be used to create other diagrams as desired by the user. The macros run in Microsoft Excel 3.0 and 4.0 for Macintosh computers and in Microsoft Excel 3.0 and 4.0 for Windows. Macros provided in PETRO.CALC.PLOT minimize repetition and time required to recalculate and plot whole-rock oxide data for petrologic analysis. ?? 1994.

  16. Mobile Monitoring Stations and Web Visualization of Biotelemetric System - Guardian II

    NASA Astrophysics Data System (ADS)

    Krejcar, Ondrej; Janckulik, Dalibor; Motalova, Leona; Kufel, Jan

    The main area of interest of our project is to provide solution which can be used in different areas of health care and which will be available through PDAs (Personal Digital Assistants), web browsers or desktop clients. The realized system deals with an ECG sensor connected to mobile equipment, such as PDA/Embedded, based on Microsoft Windows Mobile operating system. The whole system is based on the architecture of .NET Compact Framework, and Microsoft SQL Server. Visualization possibilities of web interface and ECG data are also discussed and final suggestion is made to Microsoft Silverlight solution along with current screenshot representation of implemented solution. The project was successfully tested in real environment in cryogenic room (-136OC).

  17. Cross-Platform Development Techniques for Mobile Devices

    DTIC Science & Technology

    2013-09-01

    many other platforms including Windows, Blackberry , and Symbian. Each of these platforms has their own distinct architecture and programming language...sales of iPhones and the increasing use of Android-based devices have forced less successful competitors such as Microsoft, Blackberry , and Symbian... Blackberry and Windows Phone are planned [12] in this tool’s attempt to reuse code with a unified JavaScript API while at the same time supporting unique

  18. Exposing Vital Forensic Artifacts of USB Devices in the Windows 10 Registry

    DTIC Science & Technology

    2015-06-01

    12b. DISTRIBUTION CODE 13. ABSTRACT (maximum 200 words) Digital media devices are regularly seized pursuant to criminal investigations and...ABSTRACT Digital media devices are regularly seized pursuant to criminal investigations and Microsoft Windows is the most commonly encountered... digital footprints available on seized computers that assist in re-creating a crime scene and telling the story of the events that occurred. Part of this

  19. e-Phys: a suite of intracellular neurophysiology programs integrating COM (component object model) technologies.

    PubMed

    Nguyen, Quoc-Thang; Miledi, Ricardo

    2003-09-30

    Current computer programs for intracellular recordings often lack advanced data management, are usually incompatible with other applications and are also difficult to adapt to new experiments. We have addressed these shortcomings in e-Phys, a suite of electrophysiology applications for intracellular recordings. The programs in e-Phys use Component Object Model (COM) technologies available in the Microsoft Windows operating system to provide enhanced data storage, increased interoperability between e-Phys and other COM-aware applications, and easy customization of data acquisition and analysis thanks to a script-based integrated programming environment. Data files are extensible, hierarchically organized and integrated in the Windows shell by using the Structured Storage technology. Data transfers to and from other programs are facilitated by implementing the ActiveX Automation standard and distributed COM (DCOM). ActiveX Scripting allows experimenters to write their own event-driven acquisition and analysis programs in the VBScript language from within e-Phys. Scripts can reuse components available from other programs on other machines to create distributed meta-applications. This paper describes the main features of e-Phys and how this package was used to determine the effect of the atypical antipsychotic drug clozapine on synaptic transmission at the neuromuscular junction.

  20. Alview: Portable Software for Viewing Sequence Reads in BAM Formatted Files.

    PubMed

    Finney, Richard P; Chen, Qing-Rong; Nguyen, Cu V; Hsu, Chih Hao; Yan, Chunhua; Hu, Ying; Abawi, Massih; Bian, Xiaopeng; Meerzaman, Daoud M

    2015-01-01

    The name Alview is a contraction of the term Alignment Viewer. Alview is a compiled to native architecture software tool for visualizing the alignment of sequencing data. Inputs are files of short-read sequences aligned to a reference genome in the SAM/BAM format and files containing reference genome data. Outputs are visualizations of these aligned short reads. Alview is written in portable C with optional graphical user interface (GUI) code written in C, C++, and Objective-C. The application can run in three different ways: as a web server, as a command line tool, or as a native, GUI program. Alview is compatible with Microsoft Windows, Linux, and Apple OS X. It is available as a web demo at https://cgwb.nci.nih.gov/cgi-bin/alview. The source code and Windows/Mac/Linux executables are available via https://github.com/NCIP/alview.

  1. Development of a mobile emergency patient information and imaging communication system based on CDMA-1X EVDO

    NASA Astrophysics Data System (ADS)

    Yang, Keon Ho; Jung, Haijo; Kang, Won-Suk; Jang, Bong Mun; Kim, Joong Il; Han, Dong Hoon; Yoo, Sun-Kook; Yoo, Hyung-Sik; Kim, Hee-Joung

    2006-03-01

    The wireless mobile service with a high bit rate using CDMA-1X EVDO is now widely used in Korea. Mobile devices are also increasingly being used as the conventional communication mechanism. We have developed a web-based mobile system that communicates patient information and images, using CDMA-1X EVDO for emergency diagnosis. It is composed of a Mobile web application system using the Microsoft Windows 2003 server and an internet information service. Also, a mobile web PACS used for a database managing patient information and images was developed by using Microsoft access 2003. A wireless mobile emergency patient information and imaging communication system is developed by using Microsoft Visual Studio.NET, and JPEG 2000 ActiveX control for PDA phone was developed by using the Microsoft Embedded Visual C++. Also, the CDMA-1X EVDO is used for connections between mobile web servers and the PDA phone. This system allows fast access to the patient information database, storing both medical images and patient information anytime and anywhere. Especially, images were compressed into a JPEG2000 format and transmitted from a mobile web PACS inside the hospital to the radiologist using a PDA phone located outside the hospital. Also, this system shows radiological images as well as physiological signal data, including blood pressure, vital signs and so on, in the web browser of the PDA phone so radiologists can diagnose more effectively. Also, we acquired good results using an RW-6100 PDA phone used in the university hospital system of the Sinchon Severance Hospital in Korea.

  2. Analysis of matters associated with the transferring of object-oriented applications to platform .Net using C# programming language

    NASA Astrophysics Data System (ADS)

    Sarsimbayeva, S. M.; Kospanova, K. K.

    2015-11-01

    The article provides the discussion of matters associated with the problems of transferring of object-oriented Windows applications from C++ programming language to .Net platform using C# programming language. C++ has always been considered to be the best language for the software development, but the implicit mistakes that come along with the tool may lead to infinite memory leaks and other errors. The platform .Net and the C#, made by Microsoft, are the solutions to the issues mentioned above. The world economy and production are highly demanding applications developed by C++, but the new language with its stability and transferability to .Net will bring many advantages. An example can be presented using the applications that imitate the work of queuing systems. Authors solved the problem of transferring of an application, imitating seaport works, from C++ to the platform .Net using C# in the scope of Visual Studio.

  3. Digital PIV (DPIV) Software Analysis System

    NASA Technical Reports Server (NTRS)

    Blackshire, James L.

    1997-01-01

    A software package was developed to provide a Digital PIV (DPIV) capability for NASA LaRC. The system provides an automated image capture, test correlation, and autocorrelation analysis capability for the Kodak Megaplus 1.4 digital camera system for PIV measurements. The package includes three separate programs that, when used together with the PIV data validation algorithm, constitutes a complete DPIV analysis capability. The programs are run on an IBM PC/AT host computer running either Microsoft Windows 3.1 or Windows 95 using a 'quickwin' format that allows simple user interface and output capabilities to the windows environment.

  4. MEGA7: Molecular Evolutionary Genetics Analysis Version 7.0 for Bigger Datasets.

    PubMed

    Kumar, Sudhir; Stecher, Glen; Tamura, Koichiro

    2016-07-01

    We present the latest version of the Molecular Evolutionary Genetics Analysis (Mega) software, which contains many sophisticated methods and tools for phylogenomics and phylomedicine. In this major upgrade, Mega has been optimized for use on 64-bit computing systems for analyzing larger datasets. Researchers can now explore and analyze tens of thousands of sequences in Mega The new version also provides an advanced wizard for building timetrees and includes a new functionality to automatically predict gene duplication events in gene family trees. The 64-bit Mega is made available in two interfaces: graphical and command line. The graphical user interface (GUI) is a native Microsoft Windows application that can also be used on Mac OS X. The command line Mega is available as native applications for Windows, Linux, and Mac OS X. They are intended for use in high-throughput and scripted analysis. Both versions are available from www.megasoftware.net free of charge. © The Author 2016. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. 49 CFR 1104.3 - Copies.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... fully evaluate evidence, all spreadsheets must be fully accessible and manipulable. Electronic databases... Microsoft Open Database Connectivity (ODBC) standard. ODBC is a Windows technology that allows a database software package to import data from a database created using a different software package. We currently...

  6. 49 CFR 1104.3 - Copies.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... fully evaluate evidence, all spreadsheets must be fully accessible and manipulable. Electronic databases... Microsoft Open Database Connectivity (ODBC) standard. ODBC is a Windows technology that allows a database software package to import data from a database created using a different software package. We currently...

  7. 49 CFR 1104.3 - Copies.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... fully evaluate evidence, all spreadsheets must be fully accessible and manipulable. Electronic databases... Microsoft Open Database Connectivity (ODBC) standard. ODBC is a Windows technology that allows a database software package to import data from a database created using a different software package. We currently...

  8. 49 CFR 1104.3 - Copies.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... fully evaluate evidence, all spreadsheets must be fully accessible and manipulable. Electronic databases... Microsoft Open Database Connectivity (ODBC) standard. ODBC is a Windows technology that allows a database software package to import data from a database created using a different software package. We currently...

  9. Concurrent validity of the Microsoft Kinect for Windows v2 for measuring spatiotemporal gait parameters.

    PubMed

    Dolatabadi, Elham; Taati, Babak; Mihailidis, Alex

    2016-09-01

    This paper presents a study to evaluate the concurrent validity of the Microsoft Kinect for Windows v2 for measuring the spatiotemporal parameters of gait. Twenty healthy adults performed several sequences of walks across a GAITRite mat under three different conditions: usual pace, fast pace, and dual task. Each walking sequence was simultaneously captured with two Kinect for Windows v2 and the GAITRite system. An automated algorithm was employed to extract various spatiotemporal features including stance time, step length, step time and gait velocity from the recorded Kinect v2 sequences. Accuracy in terms of reliability, concurrent validity and limits of agreement was examined for each gait feature under different walking conditions. The 95% Bland-Altman limits of agreement were narrow enough for the Kinect v2 to be a valid tool for measuring all reported spatiotemporal parameters of gait in all three conditions. An excellent intraclass correlation coefficient (ICC2, 1) ranging from 0.9 to 0.98 was observed for all gait measures across different walking conditions. The inter trial reliability of all gait parameters were shown to be strong for all walking types (ICC3, 1 > 0.73). The results of this study suggest that the Kinect for Windows v2 has the capacity to measure selected spatiotemporal gait parameters for healthy adults. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. Smartphone Applications for the Clinical Oncologist in UK Practice.

    PubMed

    Rozati, Hamoun; Shah, Sonya Pratik; Shah, Neha

    2015-06-01

    A number of medical smartphone applications have been developed to assist clinical oncology specialists. Concerns have arisen that the information provided may not be under sufficient scrutiny. This study aims to analyse the current applications available for clinical oncologists in the UK. Applications aimed specifically at physician clinical oncologists were searched for on the major smartphone operating systems: Apple iOS; Google Android; Microsoft Windows OS; and Blackberry OS. All applications were installed and analysed. The applications were scrutinised to assess the following information: cost; whether the information included was referenced; when the information was last updated; and whether they made any reference to UK guidelines. A novel rating score based on these criteria was applied to each application. Fifty applications were identified: 24 for Apple's iOS; 23 for Google's Android; 2 for Blackberry OS; and 1 for Windows OS. The categories of applications available were: drug reference; journal reference; learning; clinical calculators; decision support; guidelines; and dictionaries. Journal reference and guideline applications scored highly on our rating system. Drug reference application costs were prohibitive. Learning tools were poorly referenced and not up-to-date. Smartphones provide easy access to information. There are numerous applications devoted to oncology physicians, many of which are free and contain referenced, up-to-date data. The cost and quality of drug reference and learning applications have significant scope for improvement. A regulatory body is needed to ensure the presence of peer-reviewed, validated applications to ensure their reliability.

  11. 49 CFR 1104.3 - Copies.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Microsoft Open Database Connectivity (ODBC) standard. ODBC is a Windows technology that allows a database software package to import data from a database created using a different software package. We currently...-compatible format. All databases must be supported with adequate documentation on data attributes, SQL...

  12. INDOOR AIR QUALITY AND INHALATION EXPOSURE - SIMULATION TOOL KIT

    EPA Science Inventory

    A Microsoft Windows-based indoor air quality (IAQ) simulation software package is presented. Named Simulation Tool Kit for Indoor Air Quality and Inhalation Exposure, or IAQX for short, this package complements and supplements existing IAQ simulation programs and is desi...

  13. 78 FR 65440 - Notice of Funds Availability (NOFA) Inviting Applications for the Native American CDFI Assistance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-31

    ... of multiple mandatory documents including: (1) a PDF fillable Applicant intake form; (2) a Microsoft Excel Workbook; (3) a Microsoft Word Narrative template; and (4) other mandatory attachments. (Applicants must use the Microsoft Word Narrative template the CDFI Fund provides; alternative templates...

  14. Software for Allocating Resources in the Deep Space Network

    NASA Technical Reports Server (NTRS)

    Wang, Yeou-Fang; Borden, Chester; Zendejas, Silvino; Baldwin, John

    2003-01-01

    TIGRAS 2.0 is a computer program designed to satisfy a need for improved means for analyzing the tracking demands of interplanetary space-flight missions upon the set of ground antenna resources of the Deep Space Network (DSN) and for allocating those resources. Written in Microsoft Visual C++, TIGRAS 2.0 provides a single rich graphical analysis environment for use by diverse DSN personnel, by connecting to various data sources (relational databases or files) based on the stages of the analyses being performed. Notable among the algorithms implemented by TIGRAS 2.0 are a DSN antenna-load-forecasting algorithm and a conflict-aware DSN schedule-generating algorithm. Computers running TIGRAS 2.0 can also be connected using SOAP/XML to a Web services server that provides analysis services via the World Wide Web. TIGRAS 2.0 supports multiple windows and multiple panes in each window for users to view and use information, all in the same environment, to eliminate repeated switching among various application programs and Web pages. TIGRAS 2.0 enables the use of multiple windows for various requirements, trajectory-based time intervals during which spacecraft are viewable, ground resources, forecasts, and schedules. Each window includes a time navigation pane, a selection pane, a graphical display pane, a list pane, and a statistics pane.

  15. 78 FR 65431 - Notice of Funds Availability (NOFA) Inviting Applications for the Community Development Financial...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-31

    ... form; (2) a Microsoft Excel Workbook; (3) a Microsoft Word Narrative template; and (4) other mandatory attachments. (Applicants must use the Microsoft Word Narrative template the CDFI Fund provides; alternative...

  16. CHROMA: consensus-based colouring of multiple alignments for publication.

    PubMed

    Goodstadt, L; Ponting, C P

    2001-09-01

    CHROMA annotates multiple protein sequence alignments by consensus to produce formatted and coloured text suitable for incorporation into other documents for publication. The package is designed to be flexible and reliable, and has a simple-to-use graphical user interface running under Microsoft Windows. Both the executables and source code for CHROMA running under Windows and Linux (portable command-line only) are freely available at http://www.lg.ndirect.co.uk/chroma. Software enquiries should be directed to CHROMA@lg.ndirect.co.uk.

  17. PIV Data Validation Software Package

    NASA Technical Reports Server (NTRS)

    Blackshire, James L.

    1997-01-01

    A PIV data validation and post-processing software package was developed to provide semi-automated data validation and data reduction capabilities for Particle Image Velocimetry data sets. The software provides three primary capabilities including (1) removal of spurious vector data, (2) filtering, smoothing, and interpolating of PIV data, and (3) calculations of out-of-plane vorticity, ensemble statistics, and turbulence statistics information. The software runs on an IBM PC/AT host computer working either under Microsoft Windows 3.1 or Windows 95 operating systems.

  18. Cloud Collaboration: Cloud-Based Instruction for Business Writing Class

    ERIC Educational Resources Information Center

    Lin, Charlie; Yu, Wei-Chieh Wayne; Wang, Jenny

    2014-01-01

    Cloud computing technologies, such as Google Docs, Adobe Creative Cloud, Dropbox, and Microsoft Windows Live, have become increasingly appreciated to the next generation digital learning tools. Cloud computing technologies encourage students' active engagement, collaboration, and participation in their learning, facilitate group work, and support…

  19. A PC-based single-ADC multi-parameter data acquisition system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodring, M.; Kegel, G.H.R.; Egan, J.J.

    1995-10-01

    A personal computer (PC) based mult parameter data acquisition system using the Microsoft Window operating environment has been designed and constructed. An IBI AT compatible personal computer with an Intel 486DX5 microprocessor was combined with a National Instruments ATIDIO 32 digital I/O card, a single Canberra 8713 ADC with 13-bit resolution and a modified Canberra 8223 8-input analog multiplexer to acquil data from experiments carried out at the UML Van de Graa accelerator. The accelerator data acquisition (ADAC) computer environment was programmed in Microsoft Visual BASIC for use i Windows. ADAC allows event-mode data acquisition with up to eight parametersmore » (modifiable to 64) and the simultaneous display parameters during acquisition. Additional features of ADAC include replay of event-mode data and graphical analysis/display of data. TV ADAC environment is easy to upgrade or expand, inexpensive 1 implement, and is specifically designed to meet the needs of nuclei spectroscopy.« less

  20. Fault isolation detection expert (FIDEX). Part 1: Expert system diagnostics for a 30/20 Gigahertz satellite transponder

    NASA Technical Reports Server (NTRS)

    Durkin, John; Schlegelmilch, Richard; Tallo, Donald

    1992-01-01

    LeRC has recently completed the design of a Ka-band satellite transponder system, as part of the Advanced Communication Technology Satellite (ACTS) System. To enhance the reliability of this satellite, NASA funded the University of Akron to explore the application of an expert system to provide the transponder with an autonomous diagnosis capability. The results of this research was the development of a prototype diagnosis expert system called FIDEX (fault-isolation and diagnosis expert). FIDEX is a frame-based expert system that was developed in the NEXPERT Object development environment by Neuron Data, Inc. It is a MicroSoft Windows version 3.0 application, and was designed to operate on an Intel i80386 based personal computer system.

  1. Model driven development of clinical information sytems using openEHR.

    PubMed

    Atalag, Koray; Yang, Hong Yul; Tempero, Ewan; Warren, Jim

    2011-01-01

    openEHR and the recent international standard (ISO 13606) defined a model driven software development methodology for health information systems. However there is little evidence in the literature describing implementation; especially for desktop clinical applications. This paper presents an implementation pathway using .Net/C# technology for Microsoft Windows desktop platforms. An endoscopy reporting application driven by openEHR Archetypes and Templates has been developed. A set of novel GUI directives has been defined and presented which guides the automatic graphical user interface generator to render widgets properly. We also reveal the development steps and important design decisions; from modelling to the final software product. This might provide guidance for other developers and form evidence required for the adoption of these standards for vendors and national programs alike.

  2. CatReg Software for Categorical Regression Analysis (May 2016)

    EPA Science Inventory

    CatReg 3.0 is a Microsoft Windows enhanced version of the Agency’s categorical regression analysis (CatReg) program. CatReg complements EPA’s existing Benchmark Dose Software (BMDS) by greatly enhancing a risk assessor’s ability to determine whether data from separate toxicologic...

  3. Analog Spectrophotometers in the Digital Age: Data Acquisition on a Budget

    ERIC Educational Resources Information Center

    Nazarenko, Alexander Y.; Nazarenko, Natalie A.

    2005-01-01

    The interfacing of various spectrometers with analog output to a personal computer running Microsoft Excel in the Windows environment is described. This low cost data acquisition solution is a useful replacement of a chart recorder for various UV-visible and infrared scanning spectrophotometers.

  4. First Experiences with Kinect v2 Sensor for Close Range 3d Modelling

    NASA Astrophysics Data System (ADS)

    Lachat, E.; Macher, H.; Mittet, M.-A.; Landes, T.; Grussenmeyer, P.

    2015-02-01

    RGB-D cameras, also known as range imaging cameras, are a recent generation of sensors. As they are suitable for measuring distances to objects at high frame rate, such sensors are increasingly used for 3D acquisitions, and more generally for applications in robotics or computer vision. This kind of sensors became popular especially since the Kinect v1 (Microsoft) arrived on the market in November 2010. In July 2014, Windows has released a new sensor, the Kinect for Windows v2 sensor, based on another technology as its first device. However, due to its initial development for video games, the quality assessment of this new device for 3D modelling represents a major investigation axis. In this paper first experiences with Kinect v2 sensor are related, and the ability of close range 3D modelling is investigated. For this purpose, error sources on output data as well as a calibration approach are presented.

  5. USB Storage Device Forensics for Windows 10.

    PubMed

    Arshad, Ayesha; Iqbal, Waseem; Abbas, Haider

    2018-05-01

    Significantly increased use of USB devices due to their user-friendliness and large storage capacities poses various threats for many users/companies in terms of data theft that becomes easier due to their efficient mobility. Investigations for such data theft activities would require gathering critical digital information capable of recovering digital forensics artifacts like date, time, and device information. This research gathers three sets of registry and logs data: first, before insertion; second, during insertion; and the third, after removal of a USB device. These sets are analyzed to gather evidentiary information from Registry and Windows Event log that helps in tracking a USB device. This research furthers the prior research on earlier versions of Microsoft Windows and compares it with latest Windows 10 system. Comparison of Windows 8 and Windows 10 does not show much difference except for new subkey under USB Key in registry. However, comparison of Windows 7 with latest version indicates significant variances. © 2017 American Academy of Forensic Sciences.

  6. Capturing, Codifying and Scoring Complex Data for Innovative, Computer-Based Items.

    ERIC Educational Resources Information Center

    Luecht, Richard M.

    The Microsoft Certification Program (MCP) includes many new computer-based item types, based on complex cases involving the Windows 2000 (registered) operating system. This Innovative Item Technology (IIT) has presented challenges beyond traditional psychometric considerations such as capturing and storing the relevant response data from…

  7. PowerPoint Workshop for Teachers[TM].

    ERIC Educational Resources Information Center

    Caughlin, Janet

    This guide for teachers to the Microsoft PowerPoint multimedia presentation program begins with a section that introduces what PowerPoint is and why teachers should use it, Windows 95/98 basics, Macintosh basics, getting started, PowerPoint toolbars, and presentation tips. The next section discusses learning PowerPoint, including creating a…

  8. HPC: Rent or Buy

    ERIC Educational Resources Information Center

    Fredette, Michelle

    2012-01-01

    "Rent or buy?" is a question people ask about everything from housing to textbooks. It is also a question universities must consider when it comes to high-performance computing (HPC). With the advent of Amazon's Elastic Compute Cloud (EC2), Microsoft Windows HPC Server, Rackspace's OpenStack, and other cloud-based services, researchers now have…

  9. Ideas without Words--Internationalizing Business Presentations.

    ERIC Educational Resources Information Center

    Sondak, Norman; Sondak, Eileen

    This paper presents elements of the computer graphics environment including information on: Lotus 1-2-3; Apple Macintosh; Desktop Publishing; Object-Oriented Programming; and Microsoft's Windows 3. A brief scenario illustrates the use of the minimization principle in presenting a new product to a group of international financiers. A taxonomy of…

  10. Optimizing Secure Communication Standards for Disadvantaged Networks

    DTIC Science & Technology

    2009-09-01

    created using LATEX with the editor Kile [5]. 5.1.2 Libraries and APIs Several libraries were important to the successful completion of this study. The...Explorer. http://www.microsoft.com/windows/ internet-explorer/default.aspx. [5] Kile - An Integrated LaTeX Environment. http://kile.sourceforge.net/. [6

  11. SIMULATION TOOL KIT FOR INDOOR AIR QUALITY AND INHALATION EXPOSURE (IAQX) VERSION 1.0 USER'S GUIDE

    EPA Science Inventory

    The User's Guide describes a Microsoft Windows-based indoor air quality (IAQ) simulation software package designed Simulation Tool Kit for Indoor Air Quality and Inhalation Exposure, or IAQX for short. This software complements and supplements existing IAQ simulation programs and...

  12. Cloud computing for comparative genomics with windows azure platform.

    PubMed

    Kim, Insik; Jung, Jae-Yoon; Deluca, Todd F; Nelson, Tristan H; Wall, Dennis P

    2012-01-01

    Cloud computing services have emerged as a cost-effective alternative for cluster systems as the number of genomes and required computation power to analyze them increased in recent years. Here we introduce the Microsoft Azure platform with detailed execution steps and a cost comparison with Amazon Web Services.

  13. THE USE OF COMPUTER MODELING PACKAGES TO ILLUSTRATE UNCERTAINTY IN RISK ASSESSMENTS: AN EASE OF USE AND INTERPRETATION COMPARISON

    EPA Science Inventory

    Consistent improvements in processor speed and computer access have substantially increased the use of computer modeling by experts and non-experts alike. Several new computer modeling packages operating under graphical operating systems (i.e. Microsoft Windows or Macintosh) m...

  14. Cloud Computing for Comparative Genomics with Windows Azure Platform

    PubMed Central

    Kim, Insik; Jung, Jae-Yoon; DeLuca, Todd F.; Nelson, Tristan H.; Wall, Dennis P.

    2012-01-01

    Cloud computing services have emerged as a cost-effective alternative for cluster systems as the number of genomes and required computation power to analyze them increased in recent years. Here we introduce the Microsoft Azure platform with detailed execution steps and a cost comparison with Amazon Web Services. PMID:23032609

  15. PR-EDB: Power Reactor Embrittlement Database - Version 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Jy-An John; Subramani, Ranjit

    2008-03-01

    The aging and degradation of light-water reactor pressure vessels is of particular concern because of their relevance to plant integrity and the magnitude of the expected irradiation embrittlement. The radiation embrittlement of reactor pressure vessel materials depends on many factors, such as neutron fluence, flux, and energy spectrum, irradiation temperature, and preirradiation material history and chemical compositions. These factors must be considered to reliably predict pressure vessel embrittlement and to ensure the safe operation of the reactor. Large amounts of data from surveillance capsules are needed to develop a generally applicable damage prediction model that can be used for industrymore » standards and regulatory guides. Furthermore, the investigations of regulatory issues such as vessel integrity over plant life, vessel failure, and sufficiency of current codes, Standard Review Plans (SRPs), and Guides for license renewal can be greatly expedited by the use of a well-designed computerized database. The Power Reactor Embrittlement Database (PR-EDB) is such a comprehensive collection of data for U.S. designed commercial nuclear reactors. The current version of the PR-EDB lists the test results of 104 heat-affected-zone (HAZ) materials, 115 weld materials, and 141 base materials, including 103 plates, 35 forgings, and 3 correlation monitor materials that were irradiated in 321 capsules from 106 commercial power reactors. The data files are given in dBASE format and can be accessed with any personal computer using the Windows operating system. "User-friendly" utility programs have been written to investigate radiation embrittlement using this database. Utility programs allow the user to retrieve, select and manipulate specific data, display data to the screen or printer, and fit and plot Charpy impact data. The PR-EDB Version 3.0 upgrades Version 2.0. The package was developed based on the Microsoft .NET framework technology and uses Microsoft Access for backend data storage, and Microsoft Excel for plotting graphs. This software package is compatible with Windows (98 or higher) and has been built with a highly versatile user interface. PR-EDB Version 3.0 also contains an "Evaluated Residual File" utility for generating the evaluated processed files used for radiation embrittlement study.« less

  16. ERMes: Open Source Simplicity for Your E-Resource Management

    ERIC Educational Resources Information Center

    Doering, William; Chilton, Galadriel

    2009-01-01

    ERMes, the latest version of electronic resource management system (ERM), is a relational database; content in different tables connects to, and works with, content in other tables. ERMes requires Access 2007 (Windows) or Access 2008 (Mac) to operate as the database utilizes functionality not available in previous versions of Microsoft Access. The…

  17. SigrafW: An Easy-to-Use Program for Fitting Enzyme Kinetic Data

    ERIC Educational Resources Information Center

    Leone, Francisco Assis; Baranauskas, Jose Augusto; Furriel, Rosa Prazeres Melo; Borin, Ivana Aparecida

    2005-01-01

    SigrafW is Windows-compatible software developed using the Microsoft[R] Visual Basic Studio program that uses the simplified Hill equation for fitting kinetic data from allosteric and Michaelian enzymes. SigrafW uses a modified Fibonacci search to calculate maximal velocity (V), the Hill coefficient (n), and the enzyme-substrate apparent…

  18. Creating FGDC and NBII metadata with Metavist 2005.

    Treesearch

    David J. Rugg

    2004-01-01

    This report documents a computer program for creating metadata compliant with the Federal Geographic Data Committee (FGDC) 1998 metadata standard or the National Biological Information Infrastructure (NBII) 1999 Biological Data Profile for the FGDC standard. The software runs under the Microsoft Windows 2000 and XP operating systems, and requires the presence of...

  19. 77 FR 55153 - Magnuson-Stevens Act Provisions; Fisheries Off West Coast States; Pacific Coast Groundfish...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-07

    ... regulations erroneously state that an operating system such as ``Windows 2007'' may be used; there is no such operating system so this system is removed. Corrections to Regulations Implemented as Part of the 2011-2012... follows: Sec. 660.15 Equipment requirements. * * * * * (d) * * * (1) * * * (v) Operating system: Microsoft...

  20. Keeping PCs up to Date Can Be Fun

    ERIC Educational Resources Information Center

    Goldsborough, Reid

    2004-01-01

    The "joy" of computer maintenance takes many forms. These days, automation is the byword. Operating systems such as Microsoft Windows and utility suites such as Symantec's Norton Internet Security let you automatically keep crucial parts of your computer system up to date. It's fun to watch the technology keep tabs on itself. This document offers…

  1. Equilibrator: Modeling Chemical Equilibria with Excel

    ERIC Educational Resources Information Center

    Vander Griend, Douglas A.

    2011-01-01

    Equilibrator is a Microsoft Excel program for learning about chemical equilibria through modeling, similar in function to EQS4WIN, which is no longer supported and does not work well with newer Windows operating systems. Similar to EQS4WIN, Equilibrator allows the user to define a system with temperature, initial moles, and then either total…

  2. SOLVE The performance analyst for hardwood sawmills

    Treesearch

    Jeff Palmer; Jan Wiedenbeck; Elizabeth Porterfield

    2009-01-01

    Presents the users manual and CD-ROM for SOLVE, a computer program that helps sawmill managers improve efficiency and solve problems commonly found in hardwood sawmills. SOLVE provides information on key operational factors including log size distribution, lumber grade yields, lumber recovery factor and overrun, and break-even log costs. (Microsoft Windows? Edition)...

  3. Modular Open-Source Software for Item Factor Analysis

    ERIC Educational Resources Information Center

    Pritikin, Joshua N.; Hunter, Micheal D.; Boker, Steven M.

    2015-01-01

    This article introduces an item factor analysis (IFA) module for "OpenMx," a free, open-source, and modular statistical modeling package that runs within the R programming environment on GNU/Linux, Mac OS X, and Microsoft Windows. The IFA module offers a novel model specification language that is well suited to programmatic generation…

  4. A simple method to compare firing pin marks using stereomicroscope and Microsoft office (Windows 8) tools.

    PubMed

    Suresh, R

    2017-08-01

    Pertinent marks of fired cartridge cases such as firing pin, breech face, extractor, ejector, etc. are used for firearm identification. A non-standard semiautomatic pistol and four .22rim fire cartridges (head stamp KF) is used for known source comparison study. Two test fired cartridge cases are examined under stereomicroscope. The characteristic marks are captured by digital camera and comparative analysis of striation marks is done by using different tools available in the Microsoft word (Windows 8) of a computer system. The similarities of striation marks thus obtained are highly convincing to identify the firearm. In this paper, an effort has been made to study and compare the striation marks of two fired cartridge cases using stereomicroscope, digital camera and computer system. Comparison microscope is not used in this study. The method described in this study is simple, cost effective, transport to field study and can be equipped in a crime scene vehicle to facilitate immediate on spot examination. The findings may be highly helpful to the forensic community, law enforcement agencies and students. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. A Review of Nutritional Tracking Mobile Applications for Diabetes Patient Use.

    PubMed

    Darby, Alaina; Strum, Matthew W; Holmes, Erin; Gatwood, Justin

    2016-03-01

    Diabetes, a prevalent disease in the United States, is greatly impacted by lifestyle choices, notably nutrition. The goal of this research was to determine which of the nutritional tracking applications (apps) available for Apple (Cupertino, CA) iOS, Android® (Google, Mountain View, CA), and Windows (Microsoft, Redmond, WA) platforms should be a first recommendation to diabetes patients searching for a smartphone app to aid in dietary logging and, for some apps, other varying lifestyle and health data. This project did so by identifying the smartphone apps available on the iTunes® (Apple), Google Play, and Microsoft stores that have nutritional tracking capabilities and are of potential benefit to a patient with diabetes based on certain criteria. Each of the individual apps was then evaluated to determine which would be of most benefit to a diabetes patient. The apps were assessed based on several parameters, such as their food databases, logging options, additional tracking options, interoperability with other devices and apps, and diabetes-specific resources. This information was then compiled and evaluated to determine which apps would be of most benefit for diabetes patients. This research provides valuable information for both patients and healthcare providers because the results of this study can be used as a reference for practitioners wishing to make app recommendations for diabetes patients who are implementing lifestyle change as an aspect of therapy.

  6. SuperState: a computer program for the control of operant behavioral experimentation.

    PubMed

    Zhang, Fuqiang

    2006-09-15

    Operant behavioral researches require precise control of experimental devices for delivering stimuli and monitoring behavioral responses. The author developed a software solution named SuperState for controlling hardware devices and running reinforcement schedules. The Microsoft Windows compatible software was written by use of an object-oriented programming language Borland Delphi 5.0, which has simplified the programming of the application. SuperState is a stand-alone easy-to-use green software, without the need for the experimenter to master any scripting languages. It features: (1) control of multiple operant cages running independent reinforcement schedules; (2) enough cage devices (16 digital inputs and 16 digital outputs for each cage) suitable for the need of most operant behavioral equipments; (3) control of most standard ISA-type digital interface cards including Med-Associates Super-port cards and a PCI-type card AC6412, and highly expandable to support other PCI-type interface cards; (4) high-resolution device control (1ms); (5) a built-in real-time cumulative recorder; (6) extensive data analyzing including event recorder, cumulative recorder, block analyzing; the summarized results can be transferred easily to Microsoft Excel spreadsheets through the Clipboard.

  7. MetNetMaker: a free and open-source tool for the creation of novel metabolic networks in SBML format.

    PubMed

    Forth, Thomas; McConkey, Glenn A; Westhead, David R

    2010-09-15

    An application has been developed to help with the creation and editing of Systems Biology Markup Language (SBML) format metabolic networks up to the organism scale. Networks are defined as a collection of Kyoto Encyclopedia of Genes and Genomes (KEGG) LIGAND reactions with an optional associated Enzyme Classification (EC) number for each reaction. Additional custom reactions can be defined by the user. Reactions within the network can be assigned flux constraints and compartmentalization is supported for each reaction in addition to the support for reactions that occur across compartment boundaries. Exported networks are fully SBML L2V4 compatible with an optional L2V1 export for compatibility with old versions of the COBRA toolbox. The software runs in the free Microsoft Access 2007 Runtime (Microsoft Inc.), which is included with the installer and works on Windows XP SP2 or better. Full source code is viewable in the full version of Access 2007 or 2010. Users must have a license to use the KEGG LIGAND database (free academic licensing is available). Please go to www.bioinformatics.leeds.ac.uk/~pytf/metnetmaker for software download, help and tutorials.

  8. Pyrolaser Operating System

    NASA Technical Reports Server (NTRS)

    Roberts, Floyd E., III

    1994-01-01

    Software provides for control and acquisition of data from optical pyrometer. There are six individual programs in PYROLASER package. Provides quick and easy way to set up, control, and program standard Pyrolaser. Temperature and emisivity measurements either collected as if Pyrolaser in manual operating mode or displayed on real-time strip charts and stored in standard spreadsheet format for posttest analysis. Shell supplied to allow macros, which are test-specific, added to system easily. Written using Labview software for use on Macintosh-series computers running System 6.0.3 or later, Sun Sparc-series computers running Open-Windows 3.0 or MIT's X Window System (X11R4 or X11R5), and IBM PC or compatible computers running Microsoft Windows 3.1 or later.

  9. VA's Integrated Imaging System on three platforms.

    PubMed

    Dayhoff, R E; Maloney, D L; Majurski, W J

    1992-01-01

    The DHCP Integrated Imaging System provides users with integrated patient data including text, image and graphics data. This system has been transferred from its original two screen DOS-based MUMPS platform to an X window workstation and a Microsoft Windows-based workstation. There are differences between these various platforms that impact on software design and on software development strategy. Data structures and conventions were used to isolate hardware, operating system, imaging software, and user-interface differences between platforms in the implementation of functionality for text and image display and interaction. The use of an object-oriented approach greatly increased system portability.

  10. VA's Integrated Imaging System on three platforms.

    PubMed Central

    Dayhoff, R. E.; Maloney, D. L.; Majurski, W. J.

    1992-01-01

    The DHCP Integrated Imaging System provides users with integrated patient data including text, image and graphics data. This system has been transferred from its original two screen DOS-based MUMPS platform to an X window workstation and a Microsoft Windows-based workstation. There are differences between these various platforms that impact on software design and on software development strategy. Data structures and conventions were used to isolate hardware, operating system, imaging software, and user-interface differences between platforms in the implementation of functionality for text and image display and interaction. The use of an object-oriented approach greatly increased system portability. PMID:1482983

  11. WORKING WITH WHAEM2000: SOURCE WATER ASSESSMENT FOR A GLACIAL OUTWASH WELLFIELD, VINCENNES, INDIANA (REVISED MARCH 2003)

    EPA Science Inventory

    The purpose of this document is to introduce the use of the ground water geohydrology computer program WhAEM for Microsoft Windows (32-bit), or WhAEM2000. WhAEM2000 is a public domain, ground-water flow model designed to facilitate capture zone delineation and protection area map...

  12. A Mobile Computing Solution for Collecting Functional Analysis Data on a Pocket PC

    ERIC Educational Resources Information Center

    Jackson, James; Dixon, Mark R.

    2007-01-01

    The present paper provides a task analysis for creating a computerized data system using a Pocket PC and Microsoft Visual Basic. With Visual Basic software and any handheld device running the Windows MOBLE operating system, this task analysis will allow behavior analysts to program and customize their own functional analysis data-collection…

  13. Guidance from the Graphical User Interface (GUI) Experience: What GUI Teaches about Technology Access.

    ERIC Educational Resources Information Center

    National Council on Disability, Washington, DC.

    This report investigates the use of the graphical user interface (GUI) in computer programs, the problems it creates for individuals with visual impairments or blindness, and advocacy efforts concerning this issue, which have been targeted primarily at Microsoft, producer of Windows. The report highlights the concerns of individuals with visual…

  14. An introduction to UGRS: the ultimate grading and remanufacturing system

    Treesearch

    John Moody; Charles J. Gatchell; Elizabeth S. Walker; Powsiri Klinkhachorn

    1998-01-01

    The Ultimate Grading and Remanufactming System (UGRS) is an advanced computer program for grading and remanufacturing lumber. It is an interactive program that will both grade lumber according to NHLA rules and remanufacture it for maximum value. UGRS is written to run under Microsoft Windows 3.0 or later updates and provides a sophisticated graphical user interface....

  15. South Carolina's SC LENDS: Optimizing Libraries, Transforming Lending

    ERIC Educational Resources Information Center

    Hamby, Rogan; McBride, Ray; Lundberg, Maria

    2011-01-01

    Since SC LENDS started operating in June 2009, more public libraries have come on board. All of this on the back end connects to a Mozilla-based staff client that has distributions for Mac OS X and Microsoft Windows, using SSL encryption to keep communications secure and private between remote libraries and the servers hosted at a high-end…

  16. Simultsonic: A Simulation Tool for Ultrasonic Inspection

    NASA Astrophysics Data System (ADS)

    Krishnamurthy, Adarsh; Karthikeyan, Soumya; Krishnamurthy, C. V.; Balasubramaniam, Krishnan

    2006-03-01

    A simulation program SIMULTSONIC is under development at CNDE to help determine and/or help optimize ultrasonic probe locations for inspection of complex components. SIMULTSONIC provides a ray-trace based assessment initially followed by a displacement or pressure field-based assessment for user-specified probe positions and user-selected component. Immersion and contact modes of inspection are available in SIMULTSONIC. The code written in Visual C++ operating in Microsoft Windows environment provides an interactive user interface. In this paper, the application of SIMULTSONIC to the inspection of very thin-walled pipes (with 450 um wall thickness) is described. Ray trace based assessment was done using SIMULTSONIC to determine the standoff distance and the angle of oblique incidence for an immersion mode focused transducer. A 3-cycle Hanning window pulse was chosen for simulations. Experiments were carried out to validate the simulations. The A-scans and the associated B-Scan images obtained through simulations show good correlation with experimental results, both with the arrival time of the signal as well as with the signal amplitudes. The scope of SIMULTSONIC to deal with parametrically represented surfaces will also be discussed.

  17. Seismpol_ a visual-basic computer program for interactive and automatic earthquake waveform analysis

    NASA Astrophysics Data System (ADS)

    Patanè, Domenico; Ferrari, Ferruccio

    1997-11-01

    A Microsoft Visual-Basic computer program for waveform analysis of seismic signals is presented. The program combines interactive and automatic processing of digital signals using data recorded by three-component seismic stations. The analysis procedure can be used in either an interactive earthquake analysis or an automatic on-line processing of seismic recordings. The algorithm works in the time domain using the Covariance Matrix Decomposition method (CMD), so that polarization characteristics may be computed continuously in real time and seismic phases can be identified and discriminated. Visual inspection of the particle motion in hortogonal planes of projection (hodograms) reduces the danger of misinterpretation derived from the application of the polarization filter. The choice of time window and frequency intervals improves the quality of the extracted polarization information. In fact, the program uses a band-pass Butterworth filter to process the signals in the frequency domain by analysis of a selected signal window into a series of narrow frequency bands. Significant results supported by well defined polarizations and source azimuth estimates for P and S phases are also obtained for short-period seismic events (local microearthquakes).

  18. CloudMC: a cloud computing application for Monte Carlo simulation.

    PubMed

    Miras, H; Jiménez, R; Miras, C; Gomà, C

    2013-04-21

    This work presents CloudMC, a cloud computing application-developed in Windows Azure®, the platform of the Microsoft® cloud-for the parallelization of Monte Carlo simulations in a dynamic virtual cluster. CloudMC is a web application designed to be independent of the Monte Carlo code in which the simulations are based-the simulations just need to be of the form: input files → executable → output files. To study the performance of CloudMC in Windows Azure®, Monte Carlo simulations with penelope were performed on different instance (virtual machine) sizes, and for different number of instances. The instance size was found to have no effect on the simulation runtime. It was also found that the decrease in time with the number of instances followed Amdahl's law, with a slight deviation due to the increase in the fraction of non-parallelizable time with increasing number of instances. A simulation that would have required 30 h of CPU on a single instance was completed in 48.6 min when executed on 64 instances in parallel (speedup of 37 ×). Furthermore, the use of cloud computing for parallel computing offers some advantages over conventional clusters: high accessibility, scalability and pay per usage. Therefore, it is strongly believed that cloud computing will play an important role in making Monte Carlo dose calculation a reality in future clinical practice.

  19. Converting laserdisc video to digital video: a demonstration project using brain animations.

    PubMed

    Jao, C S; Hier, D B; Brint, S U

    1995-01-01

    Interactive laserdiscs are of limited value in large group learning situations due to the expense of establishing multiple workstations. The authors implemented an alternative to laserdisc video by using indexed digital video combined with an expert system. High-quality video was captured from a laserdisc player and combined with waveform audio into an audio-video-interleave (AVI) file format in the Microsoft Video-for-Windows environment (Microsoft Corp., Seattle, WA). With the use of an expert system, a knowledge-based computer program provided random access to these indexed AVI files. The program can be played on any multimedia computer without the need for laserdiscs. This system offers a high level of interactive video without the overhead and cost of a laserdisc player.

  20. Online Maps and Cloud-Supported Location-Based Services across a Manifold of Devices

    NASA Astrophysics Data System (ADS)

    Kröpfl, M.; Buchmüller, D.; Leberl, F.

    2012-07-01

    Online mapping, miniaturization of computing devices, the "cloud", Global Navigation Satellite System (GNSS) and cell tower triangulation all coalesce into an entirely novel infrastructure for numerous innovative map applications. This impacts the planning of human activities, navigating and tracking these activities as they occur, and finally documenting their outcome for either a single user or a network of connected users in a larger context. In this paper, we provide an example of a simple geospatial application making use of this model, which we will use to explain the basic steps necessary to deploy an application involving a web service hosting geospatial information and a client software consuming the web service through an API. The application allows an insurance claim specialist to add claims to a cloud-based database including a claim location. A field agent then uses a smartphone application to query the database by proximity, and heads out to capture photographs as supporting documentation for the claim. Once the photos have been uploaded to the web service, a second web service for image matching is called in order to try and match the current photograph to previously submitted assets. Image matching is used as a pre-verification step to determine whether the coverage of the respective object is sufficient for the claim specialist to process the claim. The development of the application was based on Microsoft's® Bing Maps™, Windows Phone™, Silverlight™, Windows Azure™ and Visual Studio™, and was completed in approximately 30 labour hours split among two developers.

  1. WORKING WITH WHAEM2000: CAPTURE ZONE DELINEATION FOR A CITY WELLFIELD IN A VALLEY FILL GLACIAL OUTWASH AQUIFER SUPPORTING WELLHEAD PROTECTION

    EPA Science Inventory

    The purpose of this document is to introduce through a case study the use of the ground water geohydrology computer program WhAEM for Microsoft Windows (32-bit), or WhAEM2000. WhAEM2000 is a public domain, ground-water flow model designed to facilitate capture zone delineation an...

  2. Ordered Effects of Technology Education Units on Higher-Order Critical Thinking Skills of Middle School Students

    ERIC Educational Resources Information Center

    Mojica, Kern D.

    2010-01-01

    In this quasi-experimental quantitative study, 105 eighth grade students at a suburban middle school in New York State participated in a seven month-long project involving the ordered effects of the technology education units of Lego[R] Mindstorms(TM) NXT Robotics System, Digital Storytelling with Microsoft Windows Movie Maker, and the Marble Maze…

  3. Urban Crowns: crown analysis software to assist in quantifying urban tree benefits

    Treesearch

    Matthew F. Winn; Sang-Mook Lee Bradley; Philip A. Araman

    2010-01-01

    UrbanCrowns is a Microsoft® Windows®-based computer program developed by the U.S. Forest Service Southern Research Station. The software assists urban forestry professionals, arborists, and community volunteers in assessing and monitoring the crown characteristics of urban trees (both deciduous and coniferous) using a single side-view digital photograph. Program output...

  4. Design and implementation of I2Vote--an interactive image-based voting system using windows mobile devices.

    PubMed

    van Ooijen, P M A; Broekema, A; Oudkerk, M

    2011-08-01

    To develop, implement and test a novel audience response system (ARS) that allows image based interaction for radiology education. The ARS developed in this project is based on standard Personal Digital Assistants (PDAs) (HP iPAQ 114 classic handheld) running Microsoft® Windows Mobile® 6 Classic with a large 3.5 in. TFT touch screen (320×240 pixel resolution), high luminance and integrated IEEE 802.11b/g wireless. For software development Visual Studio 2008 professional (Microsoft) was used and all components were written in C#. Two test sessions were conducted to test the software technically followed by two real classroom tests in a radiology class for medical students on thoracic radiology. The novel ARS, called I2Vote, was successfully implemented and provided an easy to use, stable setup. The acceptance of both students and teachers was very high and the interaction with the students improved because of the anonymous interaction possibility. An easy to use handheld based ARS that enables interactive, image-based, teaching is achieved. The system effectively adds an extra dimension to the use of an ARS. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  5. Xyce Parallel Electronic Simulator Reference Guide Version 6.7.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keiter, Eric R.; Aadithya, Karthik Venkatraman; Mei, Ting

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users' Guide [1] . The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce . This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users' Guide [1] . The information herein is subject to change without notice. Copyright c 2002-2017 Sandia Corporation. All rights reserved. Trademarks Xyce TM Electronic Simulator and Xyce TMmore » are trademarks of Sandia Corporation. Orcad, Orcad Capture, PSpice and Probe are registered trademarks of Cadence Design Systems, Inc. Microsoft, Windows and Windows 7 are registered trademarks of Microsoft Corporation. Medici, DaVinci and Taurus are registered trademarks of Synopsys Corporation. Amtec and TecPlot are trademarks of Amtec Engineering, Inc. All other trademarks are property of their respective owners. Contacts World Wide Web http://xyce.sandia.gov https://info.sandia.gov/xyce (Sandia only) Email xyce@sandia.gov (outside Sandia) xyce-sandia@sandia.gov (Sandia only) Bug Reports (Sandia only) http://joseki-vm.sandia.gov/bugzilla http://morannon.sandia.gov/bugzilla« less

  6. Artificial Intelligence for Pathologists Is Not Near--It Is Here: Description of a Prototype That Can Transform How We Practice Pathology Tomorrow.

    PubMed

    Ye, Jay J

    2015-07-01

    Pathologists' daily tasks consist of both the professional interpretation of slides and the secretarial tasks of translating these interpretations into final pathology reports, the latter of which is a time-consuming endeavor for most pathologists. To describe an artificial intelligence that performs secretarial tasks, designated as Secretary-Mimicking Artificial Intelligence (SMILE). The underling implementation of SMILE is a collection of computer programs that work in concert to "listen to" the voice commands and to "watch for" the changes of windows caused by slide bar code scanning; SMILE responds to these inputs by acting upon PowerPath Client windows (Sunquest Information Systems, Tucson, Arizona) and its Microsoft Word (Microsoft, Redmond, Washington) Add-In window, eventuating in the reports being typed and finalized. Secretary-Mimicking Artificial Intelligence also communicates relevant information to the pathologist via the computer speakers and message box on the screen. Secretary-Mimicking Artificial Intelligence performs many secretarial tasks intelligently and semiautonomously, with rapidity and consistency, thus enabling pathologists to focus on slide interpretation, which results in a marked increase in productivity, decrease in errors, and reduction of stress in daily practice. Secretary-Mimicking Artificial Intelligence undergoes encounter-based learning continually, resulting in a continuous improvement in its knowledge-based intelligence. Artificial intelligence for pathologists is both feasible and powerful. The future widespread use of artificial intelligence in our profession is certainly going to transform how we practice pathology.

  7. MARD—A moving average rose diagram application for the geosciences

    NASA Astrophysics Data System (ADS)

    Munro, Mark A.; Blenkinsop, Thomas G.

    2012-12-01

    MARD 1.0 is a computer program for generating smoothed rose diagrams by using a moving average, which is designed for use across the wide range of disciplines encompassed within the Earth Sciences. Available in MATLAB®, Microsoft® Excel and GNU Octave formats, the program is fully compatible with both Microsoft® Windows and Macintosh operating systems. Each version has been implemented in a user-friendly way that requires no prior experience in programming with the software. MARD conducts a moving average smoothing, a form of signal processing low-pass filter, upon the raw circular data according to a set of pre-defined conditions selected by the user. This form of signal processing filter smoothes the angular dataset, emphasising significant circular trends whilst reducing background noise. Customisable parameters include whether the data is uni- or bi-directional, the angular range (or aperture) over which the data is averaged, and whether an unweighted or weighted moving average is to be applied. In addition to the uni- and bi-directional options, the MATLAB® and Octave versions also possess a function for plotting 2-dimensional dips/pitches in a single, lower, hemisphere. The rose diagrams from each version are exportable as one of a selection of common graphical formats. Frequently employed statistical measures that determine the vector mean, mean resultant (or length), circular standard deviation and circular variance are also included. MARD's scope is demonstrated via its application to a variety of datasets within the Earth Sciences.

  8. SutraPrep, a pre-processor for SUTRA, a model for ground-water flow with solute or energy transport

    USGS Publications Warehouse

    Provost, Alden M.

    2002-01-01

    SutraPrep facilitates the creation of three-dimensional (3D) input datasets for the USGS ground-water flow and transport model SUTRA Version 2D3D.1. It is most useful for applications in which the geometry of the 3D model domain and the spatial distribution of physical properties and boundary conditions is relatively simple. SutraPrep can be used to create a SUTRA main input (?.inp?) file, an initial conditions (?.ics?) file, and a 3D plot of the finite-element mesh in Virtual Reality Modeling Language (VRML) format. Input and output are text-based. The code can be run on any platform that has a standard FORTRAN-90 compiler. Executable code is available for Microsoft Windows.

  9. PubChemSR: A search and retrieval tool for PubChem

    PubMed Central

    Hur, Junguk; Wild, David J

    2008-01-01

    Background Recent years have seen an explosion in the amount of publicly available chemical and related biological information. A significant step has been the emergence of PubChem, which contains property information for millions of chemical structures, and acts as a repository of compounds and bioassay screening data for the NIH Roadmap. There is a strong need for tools designed for scientists that permit easy download and use of these data. We present one such tool, PubChemSR. Implementation PubChemSR (Search and Retrieve) is a freely available desktop application written for Windows using Microsoft .NET that is designed to assist scientists in search, retrieval and organization of chemical and biological data from the PubChem database. It employs SOAP web services made available by NCBI for extraction of information from PubChem. Results and Discussion The program supports a wide range of searching techniques, including queries based on assay or compound keywords and chemical substructures. Results can be examined individually or downloaded and exported in batch for use in other programs such as Microsoft Excel. We believe that PubChemSR makes it straightforward for researchers to utilize the chemical, biological and screening data available in PubChem. We present several examples of how it can be used. PMID:18482452

  10. Customising Microsoft Office to Develop a Tutorial Learning Environment

    ERIC Educational Resources Information Center

    Deacon, Andrew; Jaftha, Jacob; Horwitz, David

    2004-01-01

    Powerful applications such as Microsoft Office's Excel and Word are widely used to perform common tasks in the workplace and in education. Scripting within these applications allows unanticipated user requirements to be addressed. We show that such extensibility, intended to support office automation-type applications, is well suited to the…

  11. A hypermedia reference system to the Forest Ecosystem Management Assessment team report and some related publications.

    Treesearch

    K.M. Reynolds; H.M. Rauscher; C.V. Worth

    1995-01-01

    The hypermedia system, ForestEM, was developed in HyperWriter for use in Microsoft Windows. ForestEM version 1.0 includes text and figures from the FEMAT report and the Record of Decision and Standards and Guidelines. Hypermedia introduces two fundamental changes to knowledge management. The first is the capability to interactively store and retrieve large amounts of...

  12. Visual Information for the Desktop, version 1.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2006-03-29

    VZIN integrates visual analytics capabilities into popular desktop tools to aid a user in searching and understanding an information space. VZIN allows users to Drag-Drop-Visualize-Explore-Organize information within tools such as Microsoft Office, Windows Explorer, Excel, and Outlook. VZIN is tailorable to specific client or industry requirements. VZIN follows the desktop metaphors so that advanced analytical capabilities are available with minimal user training.

  13. Improved Distance Learning Environment For Marine Forces Reserve

    DTIC Science & Technology

    2016-09-01

    keyboard, to 20 form a desktop computer . Laptop computers share similar components but add mobility to the user. If additional desktop computers ...for stationary computing devices such as desktop PCs and laptops include the Microsoft Windows, Mac OS, and Linux families of OSs 44 (Hopkins...opportunities to all Marines. For active duty Marines, government-provided desktops and laptops (GPDLs) typically support DL T&E or learning resource

  14. YouTube War: Fighting in a World of Cameras in Every Cell Phone and Photoshop on Every Computer

    DTIC Science & Technology

    2009-11-01

    free MovieMaker 2 program that Microsoft includes with its Windows XP operating system. Mike Wendland, “From ENG to SNG : TV Technology for Covering the...the deployed soldier. 51. Wendland, “From ENG to SNG .” 52. This is based in part on the typology in Ben Venzke, “Jihadi Master Video Guide, JMVG

  15. MultiSpec—a tool for multispectral hyperspectral image data analysis

    NASA Astrophysics Data System (ADS)

    Biehl, Larry; Landgrebe, David

    2002-12-01

    MultiSpec is a multispectral image data analysis software application. It is intended to provide a fast, easy-to-use means for analysis of multispectral image data, such as that from the Landsat, SPOT, MODIS or IKONOS series of Earth observational satellites, hyperspectral data such as that from the Airborne Visible-Infrared Imaging Spectrometer (AVIRIS) and EO-1 Hyperion satellite system or the data that will be produced by the next generation of Earth observational sensors. The primary purpose for the system was to make new, otherwise complex analysis tools available to the general Earth science community. It has also found use in displaying and analyzing many other types of non-space related digital imagery, such as medical image data and in K-12 and university level educational activities. MultiSpec has been implemented for both the Apple Macintosh ® and Microsoft Windows ® operating systems (OS). The effort was first begun on the Macintosh OS in 1988. The GLOBE ( http://www.globe.gov) program supported the development of a subset of MultiSpec for the Windows OS in 1995. Since then most (but not all) of the features in the Macintosh OS version have been ported to the Windows OS version. Although copyrighted, MultiSpec with its documentation is distributed without charge. The Macintosh and Windows versions and documentation on its use are available from the World Wide Web at URL: http://dynamo.ecn.purdue.edu/˜biehl/MultiSpec/ MultiSpec is copyrighted (1991-2001) by Purdue Research Foundation, West Lafayette, Indiana 47907.

  16. Microsoft Excel Software Usage for Teaching Science and Engineering Curriculum

    ERIC Educational Resources Information Center

    Singh, Gurmukh; Siddiqui, Khalid

    2009-01-01

    In this article, our main objective is to present the use of Microsoft Software Excel 2007/2003 for teaching college and university level curriculum in science and engineering. In particular, we discuss two interesting and fascinating examples of interactive applications of Microsoft Excel targeted for undergraduate students in: 1) computational…

  17. Developing cloud applications using the e-Science Central platform.

    PubMed

    Hiden, Hugo; Woodman, Simon; Watson, Paul; Cala, Jacek

    2013-01-28

    This paper describes the e-Science Central (e-SC) cloud data processing system and its application to a number of e-Science projects. e-SC provides both software as a service (SaaS) and platform as a service for scientific data management, analysis and collaboration. It is a portable system and can be deployed on both private (e.g. Eucalyptus) and public clouds (Amazon AWS and Microsoft Windows Azure). The SaaS application allows scientists to upload data, edit and run workflows and share results in the cloud, using only a Web browser. It is underpinned by a scalable cloud platform consisting of a set of components designed to support the needs of scientists. The platform is exposed to developers so that they can easily upload their own analysis services into the system and make these available to other users. A representational state transfer-based application programming interface (API) is also provided so that external applications can leverage the platform's functionality, making it easier to build scalable, secure cloud-based applications. This paper describes the design of e-SC, its API and its use in three different case studies: spectral data visualization, medical data capture and analysis, and chemical property prediction.

  18. Developing cloud applications using the e-Science Central platform

    PubMed Central

    Hiden, Hugo; Woodman, Simon; Watson, Paul; Cala, Jacek

    2013-01-01

    This paper describes the e-Science Central (e-SC) cloud data processing system and its application to a number of e-Science projects. e-SC provides both software as a service (SaaS) and platform as a service for scientific data management, analysis and collaboration. It is a portable system and can be deployed on both private (e.g. Eucalyptus) and public clouds (Amazon AWS and Microsoft Windows Azure). The SaaS application allows scientists to upload data, edit and run workflows and share results in the cloud, using only a Web browser. It is underpinned by a scalable cloud platform consisting of a set of components designed to support the needs of scientists. The platform is exposed to developers so that they can easily upload their own analysis services into the system and make these available to other users. A representational state transfer-based application programming interface (API) is also provided so that external applications can leverage the platform's functionality, making it easier to build scalable, secure cloud-based applications. This paper describes the design of e-SC, its API and its use in three different case studies: spectral data visualization, medical data capture and analysis, and chemical property prediction. PMID:23230161

  19. Component-Based Visualization System

    NASA Technical Reports Server (NTRS)

    Delgado, Francisco

    2005-01-01

    A software system has been developed that gives engineers and operations personnel with no "formal" programming expertise, but who are familiar with the Microsoft Windows operating system, the ability to create visualization displays to monitor the health and performance of aircraft/spacecraft. This software system is currently supporting the X38 V201 spacecraft component/system testing and is intended to give users the ability to create, test, deploy, and certify their subsystem displays in a fraction of the time that it would take to do so using previous software and programming methods. Within the visualization system there are three major components: the developer, the deployer, and the widget set. The developer is a blank canvas with widget menu items that give users the ability to easily create displays. The deployer is an application that allows for the deployment of the displays created using the developer application. The deployer has additional functionality that the developer does not have, such as printing of displays, screen captures to files, windowing of displays, and also serves as the interface into the documentation archive and help system. The third major component is the widget set. The widgets are the visual representation of the items that will make up the display (i.e., meters, dials, buttons, numerical indicators, string indicators, and the like). This software was developed using Visual C++ and uses COTS (commercial off-the-shelf) software where possible.

  20. Fracture network evaluation program (FraNEP): A software for analyzing 2D fracture trace-line maps

    NASA Astrophysics Data System (ADS)

    Zeeb, Conny; Gomez-Rivas, Enrique; Bons, Paul D.; Virgo, Simon; Blum, Philipp

    2013-10-01

    Fractures, such as joints, faults and veins, strongly influence the transport of fluids through rocks by either enhancing or inhibiting flow. Techniques used for the automatic detection of lineaments from satellite images and aerial photographs, LIDAR technologies and borehole televiewers significantly enhanced data acquisition. The analysis of such data is often performed manually or with different analysis software. Here we present a novel program for the analysis of 2D fracture networks called FraNEP (Fracture Network Evaluation Program). The program was developed using Visual Basic for Applications in Microsoft Excel™ and combines features from different existing software and characterization techniques. The main novelty of FraNEP is the possibility to analyse trace-line maps of fracture networks applying the (1) scanline sampling, (2) window sampling or (3) circular scanline and window method, without the need of switching programs. Additionally, binning problems are avoided by using cumulative distributions, rather than probability density functions. FraNEP is a time-efficient tool for the characterisation of fracture network parameters, such as density, intensity and mean length. Furthermore, fracture strikes can be visualized using rose diagrams and a fitting routine evaluates the distribution of fracture lengths. As an example of its application, we use FraNEP to analyse a case study of lineament data from a satellite image of the Oman Mountains.

  1. Holographic Rovers: Augmented Reality and the Microsoft HoloLens

    NASA Technical Reports Server (NTRS)

    Toler, Laura

    2017-01-01

    Augmented Reality is an emerging field in technology, and encompasses Head Mounted Displays, smartphone apps, and even projected images. HMDs include the Meta 2, Magic Leap, Avegant Light Field, and the Microsoft HoloLens, which is evaluated specifically. The Microsoft HoloLens is designed to be used as an AR personal computer, and is being optimized with that goal in mind. Microsoft allied with the Unity3D game engine to create an SDK for interested application developers that can be used in the Unity environment.

  2. Assessment & Commitment Tracking System (ACTS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bryant, Robert A.; Childs, Teresa A.; Miller, Michael A.

    2004-12-20

    The ACTS computer code provides a centralized tool for planning and scheduling assessments, tracking and managing actions associated with assessments or that result from an event or condition, and "mining" data for reporting and analyzing information for improving performance. The ACTS application is designed to work with the MS SQL database management system. All database interfaces are written in SQL. The following software is used to develop and support the ACTS application: Cold Fusion HTML JavaScript Quest TOAD Microsoft Visual Source Safe (VSS) HTML Mailer for sending email Microsoft SQL Microsoft Internet Information Server

  3. Subcellular object quantification with Squassh3C and SquasshAnalyst.

    PubMed

    Rizk, Aurélien; Mansouri, Maysam; Ballmer-Hofer, Kurt; Berger, Philipp

    2015-11-01

    Quantitative image analysis plays an important role in contemporary biomedical research. Squassh is a method for automatic detection, segmentation, and quantification of subcellular structures and analysis of their colocalization. Here we present the applications Squassh3C and SquasshAnalyst. Squassh3C extends the functionality of Squassh to three fluorescence channels and live-cell movie analysis. SquasshAnalyst is an interactive web interface for the analysis of Squassh3C object data. It provides segmentation image overview and data exploration, figure generation, object and image filtering, and a statistical significance test in an easy-to-use interface. The overall procedure combines the Squassh3C plug-in for the free biological image processing program ImageJ and a web application working in conjunction with the free statistical environment R, and it is compatible with Linux, MacOS X, or Microsoft Windows. Squassh3C and SquasshAnalyst are available for download at www.psi.ch/lbr/SquasshAnalystEN/SquasshAnalyst.zip.

  4. Using NetMeeting for remote configuration of the Otto Bock C-Leg: technical considerations.

    PubMed

    Lemaire, E D; Fawcett, J A

    2002-08-01

    Telehealth has the potential to be a valuable tool for technical and clinical support of computer controlled prosthetic devices. This pilot study examined the use of Internet-based, desktop video conferencing for remote configuration of the Otto Bock C-Leg. Laboratory tests involved connecting two computers running Microsoft NetMeeting over a local area network (IP protocol). Over 56 Kbs(-1), DSL/Cable, and 10 Mbs(-1) LAN speeds, a prosthetist remotely configured a user's C-Leg by using Application Sharing, Live Video, and Live Audio. A similar test between sites in Ottawa and Toronto, Canada was limited by the notebook computer's 28 Kbs(-1) modem. At the 28 Kbs(-1) Internet-connection speed, NetMeeting's application sharing feature was not able to update the remote Sliders window fast enough to display peak toe loads and peak knee angles. These results support the use of NetMeeting as an accessible and cost-effective tool for remote C-Leg configuration, provided that sufficient Internet data transfer speed is available.

  5. GPFrontend and GPGraphics: graphical analysis tools for genetic association studies.

    PubMed

    Uebe, Steffen; Pasutto, Francesca; Krumbiegel, Mandy; Schanze, Denny; Ekici, Arif B; Reis, André

    2010-09-21

    Most software packages for whole genome association studies are non-graphical, purely text based programs originally designed to run with UNIX-like operating systems. Graphical output is often not intended or supposed to be performed with other command line tools, e.g. gnuplot. Using the Microsoft .NET 2.0 platform and Visual Studio 2005, we have created a graphical software package to analyze data from microarray whole genome association studies, both for a DNA-pooling based approach as well as regular single sample data. Part of this package was made to integrate with GenePool 0.8.2, a previously existing software suite for GNU/Linux systems, which we have modified to run in a Microsoft Windows environment. Further modifications cause it to generate some additional data. This enables GenePool to interact with the .NET parts created by us. The programs we developed are GPFrontend, a graphical user interface and frontend to use GenePool and create metadata files for it, and GPGraphics, a program to further analyze and graphically evaluate output of different WGA analysis programs, among them also GenePool. Our programs enable regular MS Windows users without much experience in bioinformatics to easily visualize whole genome data from a variety of sources.

  6. Microsoft Biology Initiative: .NET Bioinformatics Platform and Tools

    PubMed Central

    Diaz Acosta, B.

    2011-01-01

    The Microsoft Biology Initiative (MBI) is an effort in Microsoft Research to bring new technology and tools to the area of bioinformatics and biology. This initiative is comprised of two primary components, the Microsoft Biology Foundation (MBF) and the Microsoft Biology Tools (MBT). MBF is a language-neutral bioinformatics toolkit built as an extension to the Microsoft .NET Framework—initially aimed at the area of Genomics research. Currently, it implements a range of parsers for common bioinformatics file formats; a range of algorithms for manipulating DNA, RNA, and protein sequences; and a set of connectors to biological web services such as NCBI BLAST. MBF is available under an open source license, and executables, source code, demo applications, documentation and training materials are freely downloadable from http://research.microsoft.com/bio. MBT is a collection of tools that enable biology and bioinformatics researchers to be more productive in making scientific discoveries.

  7. Repurposing the Microsoft Kinect for Windows v2 for external head motion tracking for brain PET.

    PubMed

    Noonan, P J; Howard, J; Hallett, W A; Gunn, R N

    2015-11-21

    Medical imaging systems such as those used in positron emission tomography (PET) are capable of spatial resolutions that enable the imaging of small, functionally important brain structures. However, the quality of data from PET brain studies is often limited by subject motion during acquisition. This is particularly challenging for patients with neurological disorders or with dynamic research studies that can last 90 min or more. Restraining head movement during the scan does not eliminate motion entirely and can be unpleasant for the subject. Head motion can be detected and measured using a variety of techniques that either use the PET data itself or an external tracking system. Advances in computer vision arising from the video gaming industry could offer significant benefits when re-purposed for medical applications. A method for measuring rigid body type head motion using the Microsoft Kinect v2 is described with results presenting  ⩽0.5 mm spatial accuracy. Motion data is measured in real-time at 30 Hz using the KinectFusion algorithm. Non-rigid motion is detected using the residual alignment energy data of the KinectFusion algorithm allowing for unreliable motion to be discarded. Motion data is aligned to PET listmode data using injected pulse sequences into the PET/CT gantry allowing for correction of rigid body motion. Pilot data from a clinical dynamic PET/CT examination is shown.

  8. Repurposing the Microsoft Kinect for Windows v2 for external head motion tracking for brain PET

    NASA Astrophysics Data System (ADS)

    Noonan, P. J.; Howard, J.; Hallett, W. A.; Gunn, R. N.

    2015-11-01

    Medical imaging systems such as those used in positron emission tomography (PET) are capable of spatial resolutions that enable the imaging of small, functionally important brain structures. However, the quality of data from PET brain studies is often limited by subject motion during acquisition. This is particularly challenging for patients with neurological disorders or with dynamic research studies that can last 90 min or more. Restraining head movement during the scan does not eliminate motion entirely and can be unpleasant for the subject. Head motion can be detected and measured using a variety of techniques that either use the PET data itself or an external tracking system. Advances in computer vision arising from the video gaming industry could offer significant benefits when re-purposed for medical applications. A method for measuring rigid body type head motion using the Microsoft Kinect v2 is described with results presenting  ⩽0.5 mm spatial accuracy. Motion data is measured in real-time at 30 Hz using the KinectFusion algorithm. Non-rigid motion is detected using the residual alignment energy data of the KinectFusion algorithm allowing for unreliable motion to be discarded. Motion data is aligned to PET listmode data using injected pulse sequences into the PET/CT gantry allowing for correction of rigid body motion. Pilot data from a clinical dynamic PET/CT examination is shown.

  9. Application of Microsoft's ActiveX and DirectX technologies to the visulization of physical system dynamics

    NASA Astrophysics Data System (ADS)

    Mann, Christopher; Narasimhamurthi, Natarajan

    1998-08-01

    This paper discusses a specific implementation of a web and complement based simulation systems. The overall simulation container is implemented within a web page viewed with Microsoft's Internet Explorer 4.0 web browser. Microsoft's ActiveX/Distributed Component Object Model object interfaces are used in conjunction with the Microsoft DirectX graphics APIs to provide visualization functionality for the simulation. The MathWorks' Matlab computer aided control system design program is used as an ActiveX automation server to provide the compute engine for the simulations.

  10. Reactive Aggregate Model Protecting Against Real-Time Threats

    DTIC Science & Technology

    2014-09-01

    on the underlying functionality of three core components. • MS SQL server 2008 backend database. • Microsoft IIS running on Windows server 2008...services. The capstone tested a Linux-based Apache web server with the following software implementations: • MySQL as a Linux-based backend server for...malicious compromise. 1. Assumptions • GINA could connect to a backend MS SQL database through proper configuration of DotNetNuke. • GINA had access

  11. Comparing the Microsoft Kinect to a traditional mouse for adjusting the viewed tissue densities of three-dimensional anatomical structures

    NASA Astrophysics Data System (ADS)

    Juhnke, Bethany; Berron, Monica; Philip, Adriana; Williams, Jordan; Holub, Joseph; Winer, Eliot

    2013-03-01

    Advancements in medical image visualization in recent years have enabled three-dimensional (3D) medical images to be volume-rendered from magnetic resonance imaging (MRI) and computed tomography (CT) scans. Medical data is crucial for patient diagnosis and medical education, and analyzing these three-dimensional models rather than two-dimensional (2D) slices would enable more efficient analysis by surgeons and physicians, especially non-radiologists. An interaction device that is intuitive, robust, and easily learned is necessary to integrate 3D modeling software into the medical community. The keyboard and mouse configuration does not readily manipulate 3D models because these traditional interface devices function within two degrees of freedom, not the six degrees of freedom presented in three dimensions. Using a familiar, commercial-off-the-shelf (COTS) device for interaction would minimize training time and enable maximum usability with 3D medical images. Multiple techniques are available to manipulate 3D medical images and provide doctors more innovative ways of visualizing patient data. One such example is windowing. Windowing is used to adjust the viewed tissue density of digital medical data. A software platform available at the Virtual Reality Applications Center (VRAC), named Isis, was used to visualize and interact with the 3D representations of medical data. In this paper, we present the methodology and results of a user study that examined the usability of windowing 3D medical imaging using a Kinect™ device compared to a traditional mouse.

  12. PIV/HPIV Film Analysis Software Package

    NASA Technical Reports Server (NTRS)

    Blackshire, James L.

    1997-01-01

    A PIV/HPIV film analysis software system was developed that calculates the 2-dimensional spatial autocorrelations of subregions of Particle Image Velocimetry (PIV) or Holographic Particle Image Velocimetry (HPIV) film recordings. The software controls three hardware subsystems including (1) a Kodak Megaplus 1.4 camera and EPIX 4MEG framegrabber subsystem, (2) an IEEE/Unidex 11 precision motion control subsystem, and (3) an Alacron I860 array processor subsystem. The software runs on an IBM PC/AT host computer running either the Microsoft Windows 3.1 or Windows 95 operating system. It is capable of processing five PIV or HPIV displacement vectors per second, and is completely automated with the exception of user input to a configuration file prior to analysis execution for update of various system parameters.

  13. Aircraft stress sequence development: A complex engineering process made simple

    NASA Technical Reports Server (NTRS)

    Schrader, K. H.; Butts, D. G.; Sparks, W. A.

    1994-01-01

    Development of stress sequences for critical aircraft structure requires flight measured usage data, known aircraft loads, and established relationships between aircraft flight loads and structural stresses. Resulting cycle-by-cycle stress sequences can be directly usable for crack growth analysis and coupon spectra tests. Often, an expert in loads and spectra development manipulates the usage data into a typical sequence of representative flight conditions for which loads and stresses are calculated. For a fighter/trainer type aircraft, this effort is repeated many times for each of the fatigue critical locations (FCL) resulting in expenditure of numerous engineering hours. The Aircraft Stress Sequence Computer Program (ACSTRSEQ), developed by Southwest Research Institute under contract to San Antonio Air Logistics Center, presents a unique approach for making complex technical computations in a simple, easy to use method. The program is written in Microsoft Visual Basic for the Microsoft Windows environment.

  14. NASA Lewis Steady-State Heat Pipe Code Architecture

    NASA Technical Reports Server (NTRS)

    Mi, Ye; Tower, Leonard K.

    2013-01-01

    NASA Glenn Research Center (GRC) has developed the LERCHP code. The PC-based LERCHP code can be used to predict the steady-state performance of heat pipes, including the determination of operating temperature and operating limits which might be encountered under specified conditions. The code contains a vapor flow algorithm which incorporates vapor compressibility and axially varying heat input. For the liquid flow in the wick, Darcy s formula is employed. Thermal boundary conditions and geometric structures can be defined through an interactive input interface. A variety of fluid and material options as well as user defined options can be chosen for the working fluid, wick, and pipe materials. This report documents the current effort at GRC to update the LERCHP code for operating in a Microsoft Windows (Microsoft Corporation) environment. A detailed analysis of the model is presented. The programming architecture for the numerical calculations is explained and flowcharts of the key subroutines are given

  15. How reliable is computerized assessment of readability?

    PubMed

    Mailloux, S L; Johnson, M E; Fisher, D G; Pettibone, T J

    1995-01-01

    To assess the consistency and comparability of readability software programs, four software programs (Corporate Voice, Grammatix IV, Microsoft Word for Windows, and RightWriter) were compared. Standard materials included 28 pieces of printed educational materials on human immunodeficiency virus/acquired immunodeficiency syndrome distributed nationally and the Gettysburg Address. Statistical analyses for the educational materials revealed that each of the three formulas assessed (Flesch-Kincaid, Flesch Reading Ease, and Gunning Fog Index) provided significantly different grade equivalent scores and that the Microsoft Word program provided significantly lower grade levels and was more inconsistent in the scores provided. For the Gettysburg Address, considerable variation was revealed among formulas, with the discrepancy being up to two grade levels. When averaging across formulas, there was a variation of 1.3 grade levels between the four software programs. Given the variation between formulas and programs, implications for decisions based on results of these software programs are provided.

  16. Space Station Furnace Facility Management Information System (SSFF-MIS) Development

    NASA Technical Reports Server (NTRS)

    Meade, Robert M.

    1996-01-01

    This report summarizes the chronology, results, and lessons learned from the development of the SSFF-MIS. This system has been nearly two years in development and has yielded some valuable insights into specialized MIS development. General: In December of 1994, the Camber Corporation and Science Applications International Corporation (SAIC) were contracted to design, develop, and implement a MIS for Marshall Space Flight Center's Space Station Furnace Facility Project. The system was to be accessible from both EBM-Compatible PC and Macintosh platforms. The system was required to contain data manually entered into the MIS as well as data imported from other MSFC sources. Electronic interfaces were established for each data source and retrieval was to be performed at prescribed time intervals. The SOW requirement that predominantly drove the development software selection was the dual-platform (IBM-PC and Macintosh) requirement. The requirement that the system would be maintained by Government personnel influenced the selection of Commercial Off-the-shelf software because of its inherent stability and readily available documentation and support. Microsoft FoxPro Professional 2.6 for Windows and Macintosh was selected as the development tool. This is a software development tool that has been in use for many years. It is stable and powerful. Microsoft has since released the replacement for this product, Microsoft Visual FoxPro, but at the time of this development, it was only available on the Windows platform. The initial contract included included the requirement for capabilities relating to the Work- and Organizational Breakdown Structures, cost (plan and actuals), workforce (plan and actuals), critical path scheduling, trend analysis, procurements and contracts, interface to manufacturing, Safety and Mission Assurance, risk analysis, and technical performance indicators. It also required full documentation of the system and training of users. During the course of the contract, the requirements for Safety and Mission Assurance interface, risk analysis, and technical performance indicators were deleted. Additional capabilities were added as reflected in the Contract Chronology below. Modification 4 added the requirement for Support Contractor manpower data, the ability to manually input data not imported from non-nal sources, a general 'health' indicator screen, and remote usage. Mod 6 included the ability to change the level of planning of Civil Service Manpower at any time and the ability to manually enter Op Codes in the manufacturing data where such codes were not provided by the EMPACS database. Modification 9 included a number of changes to report contents and formats. Modification 11 required the preparation of a detailed System Design Document.

  17. Simple Web-based interactive key development software (WEBiKEY) and an example key for Kuruna (Poaceae: Bambusoideae).

    PubMed

    Attigala, Lakshmi; De Silva, Nuwan I; Clark, Lynn G

    2016-04-01

    Programs that are user-friendly and freely available for developing Web-based interactive keys are scarce and most of the well-structured applications are relatively expensive. WEBiKEY was developed to enable researchers to easily develop their own Web-based interactive keys with fewer resources. A Web-based multiaccess identification tool (WEBiKEY) was developed that uses freely available Microsoft ASP.NET technologies and an SQL Server database for Windows-based hosting environments. WEBiKEY was tested for its usability with a sample data set, the temperate woody bamboo genus Kuruna (Poaceae). WEBiKEY is freely available to the public and can be used to develop Web-based interactive keys for any group of species. The interactive key we developed for Kuruna using WEBiKEY enables users to visually inspect characteristics of Kuruna and identify an unknown specimen as one of seven possible species in the genus.

  18. Architecture for removable media USB-ARM

    DOEpatents

    Shue, Craig A.; Lamb, Logan M.; Paul, Nathanael R.

    2015-07-14

    A storage device is coupled to a computing system comprising an operating system and application software. Access to the storage device is blocked by a kernel filter driver, except exclusive access is granted to a first anti-virus engine. The first anti-virus engine is directed to scan the storage device for malicious software and report results. Exclusive access may be granted to one or more other anti-virus engines and they may be directed to scan the storage device and report results. Approval of all or a portion of the information on the storage device is based on the results from the first anti-virus engine and the other anti-virus engines. The storage device is presented to the operating system and access is granted to the approved information. The operating system may be a Microsoft Windows operating system. The kernel filter driver and usage of anti-virus engines may be configurable by a user.

  19. [Application of three compartment model and response surface model to clinical anesthesia using Microsoft Excel].

    PubMed

    Abe, Eiji; Abe, Mari

    2011-08-01

    With the spread of total intravenous anesthesia, clinical pharmacology has become more important. We report Microsoft Excel file applying three compartment model and response surface model to clinical anesthesia. On the Microsoft Excel sheet, propofol, remifentanil and fentanyl effect-site concentrations are predicted (three compartment model), and probabilities of no response to prodding, shaking, surrogates of painful stimuli and laryngoscopy are calculated using predicted effect-site drug concentration. Time-dependent changes in these calculated values are shown graphically. Recent development in anesthetic drug interaction studies are remarkable, and its application to clinical anesthesia with this Excel file is simple and helpful for clinical anesthesia.

  20. A Dedicated Computational Platform for Cellular Monte Carlo T-CAD Software Tools

    DTIC Science & Technology

    2015-07-14

    computer that establishes an encrypted Virtual Private Network ( OpenVPN [44]) based on the Secure Socket Layer (SSL) paradigm. Each user is given a...security certificate for each device used to connect to the computing nodes. Stable OpenVPN clients are available for Linux, Microsoft Windows, Apple OSX...platform is granted by an encrypted connection base on the Secure Socket Layer (SSL) protocol, and implemented in the OpenVPN Virtual Personal Network

  1. The Design, Development and Testing of a Multi-process Real-time Software System

    DTIC Science & Technology

    2007-03-01

    programming large systems stems from the complexity of dealing with many different details at one time. A sound engineering approach is to break...controls and 3) is portable to other OS platforms such as Microsoft Windows. Next, to reduce the complexity of the programming tasks, the system...processes depending on how often the process has to check to see if common data was modified. A good method for one process to quickly notify another

  2. Trust Me: Design Patterns for Constructing Trustworthy Trust Indicators

    DTIC Science & Technology

    2009-04-01

    contacted by Microsoft to participate in user studies, and screened out participants who either did not use Hotmail for their email or did not use IE as...purpose. We decided to tell participants that we were working on improvements for Windows Live Hotmail , and therefore we would be observing them interacting...minutes. At this point, the experimenter observed them log into their Hotmail accounts, and then left the room to observe them from our observation

  3. HapMap filter 1.0: a tool to preprocess the HapMap genotypic data for association studies.

    PubMed

    Zhang, Wei; Duan, Shiwei; Dolan, M Eileen

    2008-05-13

    The International HapMap Project provides a resource of genotypic data on single nucleotide polymorphisms (SNPs), which can be used in various association studies to identify the genetic determinants for phenotypic variations. Prior to the association studies, the HapMap dataset should be preprocessed in order to reduce the computation time and control the multiple testing problem. The less informative SNPs including those with very low genotyping rate and SNPs with rare minor allele frequencies to some extent in one or more population are removed. Some research designs only use SNPs in a subset of HapMap cell lines. Although the HapMap website and other association software packages have provided some basic tools for optimizing these datasets, a fast and user-friendly program to generate the output for filtered genotypic data would be beneficial for association studies. Here, we present a flexible, straight-forward bioinformatics program that can be useful in preparing the HapMap genotypic data for association studies by specifying cell lines and two common filtering criteria: minor allele frequencies and genotyping rate. The software was developed for Microsoft Windows and written in C++. The Windows executable and source code in Microsoft Visual C++ are available at Google Code (http://hapmap-filter-v1.googlecode.com/) or upon request. Their distribution is subject to GNU General Public License v3.

  4. MAPPI-DAT: data management and analysis for protein-protein interaction data from the high-throughput MAPPIT cell microarray platform.

    PubMed

    Gupta, Surya; De Puysseleyr, Veronic; Van der Heyden, José; Maddelein, Davy; Lemmens, Irma; Lievens, Sam; Degroeve, Sven; Tavernier, Jan; Martens, Lennart

    2017-05-01

    Protein-protein interaction (PPI) studies have dramatically expanded our knowledge about cellular behaviour and development in different conditions. A multitude of high-throughput PPI techniques have been developed to achieve proteome-scale coverage for PPI studies, including the microarray based Mammalian Protein-Protein Interaction Trap (MAPPIT) system. Because such high-throughput techniques typically report thousands of interactions, managing and analysing the large amounts of acquired data is a challenge. We have therefore built the MAPPIT cell microArray Protein Protein Interaction-Data management & Analysis Tool (MAPPI-DAT) as an automated data management and analysis tool for MAPPIT cell microarray experiments. MAPPI-DAT stores the experimental data and metadata in a systematic and structured way, automates data analysis and interpretation, and enables the meta-analysis of MAPPIT cell microarray data across all stored experiments. MAPPI-DAT is developed in Python, using R for data analysis and MySQL as data management system. MAPPI-DAT is cross-platform and can be ran on Microsoft Windows, Linux and OS X/macOS. The source code and a Microsoft Windows executable are freely available under the permissive Apache2 open source license at https://github.com/compomics/MAPPI-DAT. jan.tavernier@vib-ugent.be or lennart.martens@vib-ugent.be. Supplementary data are available at Bioinformatics online. © The Author 2017. Published by Oxford University Press.

  5. WorldWide Telescope: A Newly Open Source Astronomy Visualization System

    NASA Astrophysics Data System (ADS)

    Fay, Jonathan; Roberts, Douglas A.

    2016-01-01

    After eight years of development by Microsoft Research, WorldWide Telescope (WWT) was made an open source project at the end of June 2015. WWT was motivated by the desire to put new surveys of objects, such as the Sloan Digital Sky Survey in the context of the night sky. The development of WWT under Microsoft started with the creation of a Windows desktop client that is widely used in various education, outreach and research projects. Using this, users can explore the data built into WWT as well as data that is loaded in. Beyond exploration, WWT can be used to create tours that present various datasets a narrative format.In the past two years, the team developed a collection of web controls, including an HTML5 web client, which contains much of the functionality of the Windows desktop client. The project under Microsoft has deep connections with several user communities such as education through the WWT Ambassadors program, http://wwtambassadors.org/ and with planetariums and museums such as the Adler Planetarium. WWT can also support research, including using WWT to visualize the Bones of the Milky Way and rich connections between WWT and the Astrophysical Data Systems (ADS, http://labs.adsabs.harvard.edu/adsabs/). One important new research connection is the use of WWT to create dynamic and potentially interactive supplements to journal articles, which have been created in 2015.Now WWT is an open source community lead project. The source code is available in GitHub (https://github.com/WorldWideTelescope). There is significant developer documentation on the website (http://worldwidetelescope.org/Developers/) and an extensive developer workshops (http://wwtworkshops.org/?tribe_events=wwt-developer-workshop) has taken place in the fall of 2015.Now that WWT is open source anyone who has the interest in the project can be a contributor. As important as helping out with coding, the project needs people interested in documentation, testing, training and other roles.

  6. Version 3.0 of EMINERS - Economic Mineral Resource Simulator

    USGS Publications Warehouse

    Duval, Joseph S.

    2012-01-01

    Quantitative mineral resource assessment, as developed by the U.S. Geological Survey (USGS), consists of three parts: (1) development of grade and tonnage mineral deposit models; (2) delineation of tracts permissive for each deposit type; and (3) probabilistic estimation of the numbers of undiscovered deposits for each deposit type. The estimate of the number of undiscovered deposits at different levels of probability is the input to the EMINERS (Economic Mineral Resource Simulator) program. EMINERS uses a Monte Carlo statistical process to combine probabilistic estimates of undiscovered mineral deposits with models of mineral deposit grade and tonnage to estimate mineral resources. Version 3.0 of the EMINERS program is available as this USGS Open-File Report 2004-1344. Changes from version 2.0 include updating 87 grade and tonnage models, designing new templates to produce graphs showing cumulative distribution and summary tables, and disabling economic filters. The economic filters were disabled because embedded data for costs of labor and materials, mining techniques, and beneficiation methods are out of date. However, the cost algorithms used in the disabled economic filters are still in the program and available for reference for mining methods and milling techniques. The release notes included with this report give more details on changes in EMINERS over the years. EMINERS is written in C++ and depends upon the Microsoft Visual C++ 6.0 programming environment. The code depends heavily on the use of Microsoft Foundation Classes (MFC) for implementation of the Windows interface. The program works only on Microsoft Windows XP or newer personal computers. It does not work on Macintosh computers. For help in using the program in this report, see the "Quick-Start Guide for Version 3.0 of EMINERS-Economic Mineral Resource Simulator" (W.J. Bawiec and G.T. Spanski, 2012, USGS Open-File Report 2009-1057, linked at right). It demonstrates how to execute EMINERS software using default settings and existing deposit models.

  7. A multiobjective decision support/numerical modeling approach for design and evaluation of shallow landfill burial systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ascough, II, James Clifford

    1992-05-01

    The capability to objectively evaluate design performance of shallow landfill burial (SLB) systems is of great interest to diverse scientific disciplines, including hydrologists, engineers, environmental scientists, and SLB regulators. The goal of this work was to develop and validate a procedure for the nonsubjective evaluation of SLB designs under actual or simulated environmental conditions. A multiobjective decision module (MDM) based on scoring functions (Wymore, 1988) was implemented to evaluate SLB design performance. Input values to the MDM are provided by hydrologic models. The MDM assigns a total score to each SLB design alternative, thereby allowing for rapid and repeatable designmore » performance evaluation. The MDM was validated for a wide range of SLB designs under different climatic conditions. Rigorous assessment of SLB performance also requires incorporation of hydrologic probabilistic analysis and hydrologic risk into the overall design. This was accomplished through the development of a frequency analysis module. The frequency analysis module allows SLB design event magnitudes to be calculated based on the hydrologic return period. The multiobjective decision and freqeuncy anslysis modules were integrated in a decision support system (DSS) framework, SLEUTH (Shallow Landfill Evaluation Using Transport and Hydrology). SLEUTH is a Microsoft Windows {trademark} application, and is written in the Knowledge Pro Windows (Knowledge Garden, Inc., 1991) development language.« less

  8. Computer assisted data analysis in intensive care: the ICDEV project--development of a scientific database system for intensive care (Intensive Care Data Evaluation Project).

    PubMed

    Metnitz, P G; Laback, P; Popow, C; Laback, O; Lenz, K; Hiesmayr, M

    1995-01-01

    Patient Data Management Systems (PDMS) for ICUs collect, present and store clinical data. Various intentions make analysis of those digitally stored data desirable, such as quality control or scientific purposes. The aim of the Intensive Care Data Evaluation project (ICDEV), was to provide a database tool for the analysis of data recorded at various ICUs at the University Clinics of Vienna. General Hospital of Vienna, with two different PDMSs used: CareVue 9000 (Hewlett Packard, Andover, USA) at two ICUs (one medical ICU and one neonatal ICU) and PICIS Chart+ (PICIS, Paris, France) at one Cardiothoracic ICU. CONCEPT AND METHODS: Clinically oriented analysis of the data collected in a PDMS at an ICU was the beginning of the development. After defining the database structure we established a client-server based database system under Microsoft Windows NI and developed a user friendly data quering application using Microsoft Visual C++ and Visual Basic; ICDEV was successfully installed at three different ICUs, adjustment to the different PDMS configurations were done within a few days. The database structure developed by us enables a powerful query concept representing an 'EXPERT QUESTION COMPILER' which may help to answer almost any clinical questions. Several program modules facilitate queries at the patient, group and unit level. Results from ICDEV-queries are automatically transferred to Microsoft Excel for display (in form of configurable tables and graphs) and further processing. The ICDEV concept is configurable for adjustment to different intensive care information systems and can be used to support computerized quality control. However, as long as there exists no sufficient artifact recognition or data validation software for automatically recorded patient data, the reliability of these data and their usage for computer assisted quality control remain unclear and should be further studied.

  9. Adobe acrobat: an alternative electronic teaching file construction methodology independent of HTML restrictions.

    PubMed

    Katzman, G L

    2001-03-01

    The goal of the project was to create a method by which an in-house digital teaching file could be constructed that was simple, inexpensive, independent of hypertext markup language (HTML) restrictions, and appears identical on multiple platforms. To accomplish this, Microsoft PowerPoint and Adobe Acrobat were used in succession to assemble digital teaching files in the Acrobat portable document file format. They were then verified to appear identically on computers running Windows, Macintosh Operating Systems (OS), and the Silicon Graphics Unix-based OS as either a free-standing file using Acrobat Reader software or from within a browser window using the Acrobat browser plug-in. This latter display method yields a file viewed through a browser window, yet remains independent of underlying HTML restrictions, which may confer an advantage over simple HTML teaching file construction. Thus, a hybrid of HTML-distributed Adobe Acrobat generated WWW documents may be a viable alternative for digital teaching file construction and distribution.

  10. "Just Another Tool for Online Studies” (JATOS): An Easy Solution for Setup and Management of Web Servers Supporting Online Studies

    PubMed Central

    Lange, Kristian; Kühn, Simone; Filevich, Elisa

    2015-01-01

    We present here “Just Another Tool for Online Studies” (JATOS): an open source, cross-platform web application with a graphical user interface (GUI) that greatly simplifies setting up and communicating with a web server to host online studies that are written in JavaScript. JATOS is easy to install in all three major platforms (Microsoft Windows, Mac OS X, and Linux), and seamlessly pairs with a database for secure data storage. It can be installed on a server or locally, allowing researchers to try the application and feasibility of their studies within a browser environment, before engaging in setting up a server. All communication with the JATOS server takes place via a GUI (with no need to use a command line interface), making JATOS an especially accessible tool for researchers without a strong IT background. We describe JATOS’ main features and implementation and provide a detailed tutorial along with example studies to help interested researchers to set up their online studies. JATOS can be found under the Internet address: www.jatos.org. PMID:26114751

  11. Worldwide Telescope as an earth and planetary science educational platform

    NASA Astrophysics Data System (ADS)

    Fatland, D. R.; Rush, K.; van Ingen, C.; Wong, C.; Fay, J.; Xu, Y.; Fay, D.

    2009-12-01

    Worldwide Telescope (WWT) -available at no cost from Microsoft Research as both Windows desktop and web browser applications - enables personal computers to function as virtual telescopes for viewing the earth, the solar system and the cosmos across many wavelengths. Bringing together imagery from ground and space-based telescopes as well as photography from Mars rovers and Apollo astronauts, WWT is designed to work as both a research tool and a platform for educational exploration. Central to the latter purpose is the Tour authoring facility which enables a student or educator to create narrative stories with dynamic perspective, voice-over narrative, background sound and superimposed content. We describe here the application of recent developments in WWT, particularly the 2009 updates, towards planetary science education with particular emphasis on WWT earth models. Two core themes informing this development are the notions of enabling social networking through WWT Communities and including the earth as part of the bigger picture, in effect swinging the telescope around from the deep sky to look back at our observatory. moon, earth (WWT solar system view)

  12. PyCorrFit-generic data evaluation for fluorescence correlation spectroscopy.

    PubMed

    Müller, Paul; Schwille, Petra; Weidemann, Thomas

    2014-09-01

    We present a graphical user interface (PyCorrFit) for the fitting of theoretical model functions to experimental data obtained by fluorescence correlation spectroscopy (FCS). The program supports many data file formats and features a set of tools specialized in FCS data evaluation. The Python source code is freely available for download from the PyCorrFit web page at http://pycorrfit.craban.de. We offer binaries for Ubuntu Linux, Mac OS X and Microsoft Windows. © The Author 2014. Published by Oxford University Press.

  13. Implementation of Wireless Input Methods (Game Controllers and Accelerometers) for Simulated Weapon Trigger Fire in the Computer Assisted Rehabilitation Environment (CAREN)

    DTIC Science & Technology

    2013-08-22

    software. Using this weapon, two ways of sending trigger fire response to the D-Flow software were proposed. One was to integrate a wireless game...Logitech International, S.A., Romanel-sur- Morges, Switzerland) and the Xbox 360 wireless controller for Windows (Microsoft, Redmond, WA). The circuit board...power on and off the game controller so that the batteries do not drain (though these devices will time out after approximately 10 minutes of

  14. Object-oriented developmental environment for image-analysis applications: implementation for 2D gel electrophoretogram analysis.

    PubMed

    Pánek, J; Vohradský, J

    1997-06-01

    The principal motivation was to design an environment for the development of image-analysis applications which would allow the integration of independent modules into one frame and make available tools for their build-up, running, management and mutual communication. The system was designed as modular, consisting of the core and work modules. The system core focuses on overall management and provides a library of classes for build-up of the work modules, their user interface and data communication. The work modules carry practical implementation of algorithms and data structures for the solution of a particular problem, and were implemented as dynamic-link libraries. They are mutually independent and run as individual threads, communicating with each other via a unified mechanism. The environment was designed to simplify the development and testing of new algorithms or applications. An example of implementation for the particular problem of the analysis of two-dimensional (2D) gel electrophoretograms is presented. The environment was designed for the Windows NT operating system with the use of Microsoft Foundation Class Library employing the possibilities of C++ programming language. Available on request from the authors.

  15. User's Manual: Routines for Radiative Heat Transfer and Thermometry

    NASA Technical Reports Server (NTRS)

    Risch, Timothy K.

    2016-01-01

    Determining the intensity and spectral distribution of radiation emanating from a heated surface has applications in many areas of science and engineering. Areas of research in which the quantification of spectral radiation is used routinely include thermal radiation heat transfer, infrared signature analysis, and radiation thermometry. In the analysis of radiation, it is helpful to be able to predict the radiative intensity and the spectral distribution of the emitted energy. Presented in this report is a set of routines written in Microsoft Visual Basic for Applications (VBA) (Microsoft Corporation, Redmond, Washington) and incorporating functions specific to Microsoft Excel (Microsoft Corporation, Redmond, Washington) that are useful for predicting the radiative behavior of heated surfaces. These routines include functions for calculating quantities of primary importance to engineers and scientists. In addition, the routines also provide the capability to use such information to determine surface temperatures from spectral intensities and for calculating the sensitivity of the surface temperature measurements to unknowns in the input parameters.

  16. Implementing Audio-CASI on Windows’ Platforms

    PubMed Central

    Cooley, Philip C.; Turner, Charles F.

    2011-01-01

    Audio computer-assisted self interviewing (Audio-CASI) technologies have recently been shown to provide important and sometimes dramatic improvements in the quality of survey measurements. This is particularly true for measurements requiring respondents to divulge highly sensitive information such as their sexual, drug use, or other sensitive behaviors. However, DOS-based Audio-CASI systems that were designed and adopted in the early 1990s have important limitations. Most salient is the poor control they provide for manipulating the video presentation of survey questions. This article reports our experiences adapting Audio-CASI to Microsoft Windows 3.1 and Windows 95 platforms. Overall, our Windows-based system provided the desired control over video presentation and afforded other advantages including compatibility with a much wider array of audio devices than our DOS-based Audio-CASI technologies. These advantages came at the cost of increased system requirements --including the need for both more RAM and larger hard disks. While these costs will be an issue for organizations converting large inventories of PCS to Windows Audio-CASI today, this will not be a serious constraint for organizations and individuals with small inventories of machines to upgrade or those purchasing new machines today. PMID:22081743

  17. Measuring and Inferring the State of the User via the Microsoft Kinect with Application to Cyber Security Research

    DTIC Science & Technology

    2018-01-16

    ARL-TN-0864 ● JAN 2018 US Army Research Laboratory Measuring and Inferring the State of the User via the Microsoft Kinect with...Application to Cyber Security Research by Christopher J Garneau Approved for public release; distribution is unlimited...this report when it is no longer needed. Do not return it to the originator. ARL-TN-0864● JAN 2018 US Army Research Laboratory

  18. [MapDraw: a microsoft excel macro for drawing genetic linkage maps based on given genetic linkage data].

    PubMed

    Liu, Ren-Hu; Meng, Jin-Ling

    2003-05-01

    MAPMAKER is one of the most widely used computer software package for constructing genetic linkage maps.However, the PC version, MAPMAKER 3.0 for PC, could not draw the genetic linkage maps that its Macintosh version, MAPMAKER 3.0 for Macintosh,was able to do. Especially in recent years, Macintosh computer is much less popular than PC. Most of the geneticists use PC to analyze their genetic linkage data. So a new computer software to draw the same genetic linkage maps on PC as the MAPMAKER for Macintosh to do on Macintosh has been crying for. Microsoft Excel,one component of Microsoft Office package, is one of the most popular software in laboratory data processing. Microsoft Visual Basic for Applications (VBA) is one of the most powerful functions of Microsoft Excel. Using this program language, we can take creative control of Excel, including genetic linkage map construction, automatic data processing and more. In this paper, a Microsoft Excel macro called MapDraw is constructed to draw genetic linkage maps on PC computer based on given genetic linkage data. Use this software,you can freely construct beautiful genetic linkage map in Excel and freely edit and copy it to Word or other application. This software is just an Excel format file. You can freely copy it from ftp://211.69.140.177 or ftp://brassica.hzau.edu.cn and the source code can be found in Excel's Visual Basic Editor.

  19. BanTeC: a software tool for management of corneal transplantation.

    PubMed

    López-Alvarez, P; Caballero, F; Trias, J; Cortés, U; López-Navidad, A

    2005-11-01

    Until recently, all cornea information at our tissue bank was managed manually, no specific database or computer tool had been implemented to provide electronic versions of documents and medical reports. The main objective of the BanTeC project was therefore to create a computerized system to integrate and classify all the information and documents used in the center in order to facilitate management of retrieved, transplanted corneal tissues. We used the Windows platform to develop the project. Microsoft Access and Microsoft Jet Engine were used at the database level and Data Access Objects was the chosen data access technology. In short, the BanTeC software seeks to computerize the tissue bank. All the initial stages of the development have now been completed, from specification of needs, program design and implementation of the software components, to the total integration of the final result in the real production environment. BanTeC will allow the generation of statistical reports for analysis to improve our performance.

  20. A Java viewer to publish Digital Imaging and Communications in Medicine (DICOM) radiologic images on the World Wide Web.

    PubMed

    Setti, E; Musumeci, R

    2001-06-01

    The world wide web is an exciting service that allows one to publish electronic documents made of text and images on the internet. Client software called a web browser can access these documents, and display and print them. The most popular browsers are currently Microsoft Internet Explorer (Microsoft, Redmond, WA) and Netscape Communicator (Netscape Communications, Mountain View, CA). These browsers can display text in hypertext markup language (HTML) format and images in Joint Photographic Expert Group (JPEG) and Graphic Interchange Format (GIF). Currently, neither browser can display radiologic images in native Digital Imaging and Communications in Medicine (DICOM) format. With the aim to publish radiologic images on the internet, we wrote a dedicated Java applet. Our software can display radiologic and histologic images in DICOM, JPEG, and GIF formats, and provides a a number of functions like windowing and magnification lens. The applet is compatible with some web browsers, even the older versions. The software is free and available from the author.

  1. Controlling EPICS from a web browser.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, K., Jr.

    1999-04-13

    An alternative to using a large graphical display manager like MEDM [1,2] to interface to a control system, is to use individual control objects, such as text boxes, meters, etc., running in a browser. This paper presents three implementations of this concept, one using ActiveX controls, one with Java applets, and another with Microsoft Agent. The ActiveX controls have performance nearing that of MEDM, but they only work on Windows platforms. The Java applets require a server to get around Web security restrictions and are not as fast, but they have the advantage of working on most platforms and withmore » both of the leading Web browsers. The agent works on Windows platforms with and without a browser and allows voice recognition and speech synthesis, making it somewhat more innovative than MEDM.« less

  2. imDEV: a graphical user interface to R multivariate analysis tools in Microsoft Excel

    USDA-ARS?s Scientific Manuscript database

    Interactive modules for data exploration and visualization (imDEV) is a Microsoft Excel spreadsheet embedded application providing an integrated environment for the analysis of omics data sets with a user-friendly interface. Individual modules were designed to provide toolsets to enable interactive ...

  3. Validation of the Microsoft Kinect® camera system for measurement of lower extremity jump landing and squatting kinematics.

    PubMed

    Eltoukhy, Moataz; Kelly, Adam; Kim, Chang-Young; Jun, Hyung-Pil; Campbell, Richard; Kuenze, Christopher

    2016-01-01

    Cost effective, quantifiable assessment of lower extremity movement represents potential improvement over standard tools for evaluation of injury risk. Ten healthy participants completed three trials of a drop jump, overhead squat, and single leg squat task. Peak hip and knee kinematics were assessed using an 8 camera BTS Smart 7000DX motion analysis system and the Microsoft Kinect® camera system. The agreement and consistency between both uncorrected and correct Kinect kinematic variables and the BTS camera system were assessed using interclass correlations coefficients. Peak sagittal plane kinematics measured using the Microsoft Kinect® camera system explained a significant amount of variance [Range(hip) = 43.5-62.8%; Range(knee) = 67.5-89.6%] in peak kinematics measured using the BTS camera system. Across tasks, peak knee flexion angle and peak hip flexion were found to be consistent and in agreement when the Microsoft Kinect® camera system was directly compared to the BTS camera system but these values were improved following application of a corrective factor. The Microsoft Kinect® may not be an appropriate surrogate for traditional motion analysis technology, but it may have potential applications as a real-time feedback tool in pathological or high injury risk populations.

  4. Developing movement recognition application with the use of Shimmer sensor and Microsoft Kinect sensor.

    PubMed

    Guzsvinecz, Tibor; Szucs, Veronika; Sik Lányi, Cecília

    2015-01-01

    Nowadays the development of virtual reality-based application is one of the most dynamically growing areas. These applications have a wide user base, more and more devices which are providing several kinds of user interactions and are available on the market. In the applications where the not-handheld devices are not necessary, the potential is that these can be used in educational, entertainment and rehabilitation applications. The purpose of this paper is to examine the precision and the efficiency of the not-handheld devices with user interaction in the virtual reality-based applications. The first task of the developed application is to support the rehabilitation process of stroke patients in their homes. A newly developed application will be introduced in this paper, which uses the two popular devices, the Shimmer sensor and the Microsoft Kinect sensor. To identify and to validate the actions of the user these sensors are working together in parallel mode. For the problem solving, the application is available to record an educational pattern, and then the software compares this pattern to the action of the user. The goal of the current research is to examine the extent of the difference in the recognition of the gestures, how precisely the two sensors are identifying the predefined actions. This could affect the rehabilitation process of the stroke patients and influence the efficiency of the rehabilitation. This application was developed in C# programming language and uses the original Shimmer connecting application as a base. During the working of this application it is possible to teach five-five different movements with the use of the Shimmer and the Microsoft Kinect sensors. The application can recognize these actions at any later time. This application uses a file-based database and the runtime memory of the application to store the saved data in order to reach the actions easier. The conclusion is that much more precise data were collected from the Microsoft Kinect sensor than the Shimmer sensors.

  5. Quick-start guide for version 3.0 of EMINERS - Economic Mineral Resource Simulator

    USGS Publications Warehouse

    Bawiec, Walter J.; Spanski, Gregory T.

    2012-01-01

    Quantitative mineral resource assessment, as developed by the U.S. Geological Survey (USGS), consists of three parts: (1) development of grade and tonnage mineral deposit models; (2) delineation of tracts permissive for each deposit type; and (3) probabilistic estimation of the numbers of undiscovered deposits for each deposit type (Singer and Menzie, 2010). The estimate of the number of undiscovered deposits at different levels of probability is the input to the EMINERS (Economic Mineral Resource Simulator) program. EMINERS uses a Monte Carlo statistical process to combine probabilistic estimates of undiscovered mineral deposits with models of mineral deposit grade and tonnage to estimate mineral resources. It is based upon a simulation program developed by Root and others (1992), who discussed many of the methods and algorithms of the program. Various versions of the original program (called "MARK3" and developed by David H. Root, William A. Scott, and Lawrence J. Drew of the USGS) have been published (Root, Scott, and Selner, 1996; Duval, 2000, 2012). The current version (3.0) of the EMINERS program is available as USGS Open-File Report 2004-1344 (Duval, 2012). Changes from version 2.0 include updating 87 grade and tonnage models, designing new templates to produce graphs showing cumulative distribution and summary tables, and disabling economic filters. The economic filters were disabled because embedded data for costs of labor and materials, mining techniques, and beneficiation methods are out of date. However, the cost algorithms used in the disabled economic filters are still in the program and available for reference for mining methods and milling techniques included in Camm (1991). EMINERS is written in C++ and depends upon the Microsoft Visual C++ 6.0 programming environment. The code depends heavily on the use of Microsoft Foundation Classes (MFC) for implementation of the Windows interface. The program works only on Microsoft Windows XP or newer personal computers. It does not work on Macintosh computers. This report demonstrates how to execute EMINERS software using default settings and existing deposit models. Many options are available when setting up the simulation. Information and explanations addressing these optional parameters can be found in the EMINERS Help files. Help files are available during execution of EMINERS by selecting EMINERS Help from the pull-down menu under Help on the EMINERS menu bar. There are four sections in this report. Part I describes the installation, setup, and application of the EMINERS program, and Part II illustrates how to interpret the text file that is produced. Part III describes the creation of tables and graphs by use of the provided Excel templates. Part IV summarizes grade and tonnage models used in version 3.0 of EMINERS.

  6. Random Vibrations

    NASA Technical Reports Server (NTRS)

    Messaro. Semma; Harrison, Phillip

    2010-01-01

    Ares I Zonal Random vibration environments due to acoustic impingement and combustion processes are develop for liftoff, ascent and reentry. Random Vibration test criteria for Ares I Upper Stage pyrotechnic components are developed by enveloping the applicable zonal environments where each component is located. Random vibration tests will be conducted to assure that these components will survive and function appropriately after exposure to the expected vibration environments. Methodology: Random Vibration test criteria for Ares I Upper Stage pyrotechnic components were desired that would envelope all the applicable environments where each component was located. Applicable Ares I Vehicle drawings and design information needed to be assessed to determine the location(s) for each component on the Ares I Upper Stage. Design and test criteria needed to be developed by plotting and enveloping the applicable environments using Microsoft Excel Spreadsheet Software and documenting them in a report Using Microsoft Word Processing Software. Conclusion: Random vibration liftoff, ascent, and green run design & test criteria for the Upper Stage Pyrotechnic Components were developed by using Microsoft Excel to envelope zonal environments applicable to each component. Results were transferred from Excel into a report using Microsoft Word. After the report is reviewed and edited by my mentor it will be submitted for publication as an attachment to a memorandum. Pyrotechnic component designers will extract criteria from my report for incorporation into the design and test specifications for components. Eventually the hardware will be tested to the environments I developed to assure that the components will survive and function appropriately after exposure to the expected vibration environments.

  7. Platform-independent software for medical image processing on the Internet

    NASA Astrophysics Data System (ADS)

    Mancuso, Michael E.; Pathak, Sayan D.; Kim, Yongmin

    1997-05-01

    We have developed a software tool for image processing over the Internet. The tool is a general purpose, easy to use, flexible, platform independent image processing software package with functions most commonly used in medical image processing.It provides for processing of medical images located wither remotely on the Internet or locally. The software was written in Java - the new programming language developed by Sun Microsystems. It was compiled and tested using Microsoft's Visual Java 1.0 and Microsoft's Just in Time Compiler 1.00.6211. The software is simple and easy to use. In order to use the tool, the user needs to download the software from our site before he/she runs it using any Java interpreter, such as those supplied by Sun, Symantec, Borland or Microsoft. Future versions of the operating systems supplied by Sun, Microsoft, Apple, IBM, and others will include Java interpreters. The software is then able to access and process any image on the iNternet or on the local computer. Using a 512 X 512 X 8-bit image, a 3 X 3 convolution took 0.88 seconds on an Intel Pentium Pro PC running at 200 MHz with 64 Mbytes of memory. A window/level operation took 0.38 seconds while a 3 X 3 median filter took 0.71 seconds. These performance numbers demonstrate the feasibility of using this software interactively on desktop computes. Our software tool supports various image processing techniques commonly used in medical image processing and can run without the need of any specialized hardware. It can become an easily accessible resource over the Internet to promote the learning and of understanding image processing algorithms. Also, it could facilitate sharing of medical image databases and collaboration amongst researchers and clinicians, regardless of location.

  8. First-year dental students' motivation and attitudes for choosing the dental profession.

    PubMed

    Avramova, Nadya; Yaneva, Krassimira; Bonev, Boyko

    2014-01-01

    To determine first-year dental students' current motivation and attitudes for choosing the dental profession at the Faculty of Dental Medicine, Medical University - Sofia, Bulgaria. An anonymous questionnaire, consisting of 12 questions about students' socio-demographic profile and their motivation for choosing dentistry, was administered to 119 first-year dental students at the Faculty of Dental Medicine of the Medical University of Sofia. The study was conducted at the beginning of the 2012-2013 academic year. The data was processed and analyzed with the following software: Microsoft Windows Server 2008 R2; Microsoft SQL Server 2008; Internet Information Server 7.5.; Microsoft SharePoint Server 2010. The majority of the students (73%) were self-motivated for choosing dentistry as a career; 61% of them did not have relatives in the medical profession; 43% chose dental medicine because it is a prestigious, humane and noble profession; 50% - for financial security; 59% - because of the independence that it provides. There were no significant differences in the motivation between males and females. Independence, financial security and 'prestige' were the predominant motivating factors in this group of first-year dental students. Determining the reasons for choosing dentistry has important implications for the selection and training of students as well as for their future job satisfaction. Copyright © 2014 by Academy of Sciences and Arts of Bosnia and Herzegovina.

  9. Software for illustrative presentation of basic clinical characteristics of laboratory tests--GraphROC for Windows.

    PubMed

    Kairisto, V; Poola, A

    1995-01-01

    GraphROC for Windows is a program for clinical test evaluation. It was designed for the handling of large datasets obtained from clinical laboratory databases. In the user interface, graphical and numerical presentations are combined. For simplicity, numerical data is not shown unless requested. Relevant numbers can be "picked up" from the graph by simple mouse operations. Reference distributions can be displayed by using automatically optimized bin widths. Any percentile of the distribution with corresponding confidence limits can be chosen for display. In sensitivity-specificity analysis, both illness- and health-related distributions are shown in the same graph. The following data for any cutoff limit can be shown in a separate click window: clinical sensitivity and specificity with corresponding confidence limits, positive and negative likelihood ratios, positive and negative predictive values and efficiency. Predictive values and clinical efficiency of the cutoff limit can be updated for any prior probability of disease. Receiver Operating Characteristics (ROC) curves can be generated and combined into the same graph for comparison of several different tests. The area under the curve with corresponding confidence interval is calculated for each ROC curve. Numerical results of analyses and graphs can be printed or exported to other Microsoft Windows programs. GraphROC for Windows also employs a new method, developed by us, for the indirect estimation of health-related limits and change limits from mixed distributions of clinical laboratory data.

  10. HeatmapGenerator: high performance RNAseq and microarray visualization software suite to examine differential gene expression levels using an R and C++ hybrid computational pipeline.

    PubMed

    Khomtchouk, Bohdan B; Van Booven, Derek J; Wahlestedt, Claes

    2014-01-01

    The graphical visualization of gene expression data using heatmaps has become an integral component of modern-day medical research. Heatmaps are used extensively to plot quantitative differences in gene expression levels, such as those measured with RNAseq and microarray experiments, to provide qualitative large-scale views of the transcriptonomic landscape. Creating high-quality heatmaps is a computationally intensive task, often requiring considerable programming experience, particularly for customizing features to a specific dataset at hand. Software to create publication-quality heatmaps is developed with the R programming language, C++ programming language, and OpenGL application programming interface (API) to create industry-grade high performance graphics. We create a graphical user interface (GUI) software package called HeatmapGenerator for Windows OS and Mac OS X as an intuitive, user-friendly alternative to researchers with minimal prior coding experience to allow them to create publication-quality heatmaps using R graphics without sacrificing their desired level of customization. The simplicity of HeatmapGenerator is that it only requires the user to upload a preformatted input file and download the publicly available R software language, among a few other operating system-specific requirements. Advanced features such as color, text labels, scaling, legend construction, and even database storage can be easily customized with no prior programming knowledge. We provide an intuitive and user-friendly software package, HeatmapGenerator, to create high-quality, customizable heatmaps generated using the high-resolution color graphics capabilities of R. The software is available for Microsoft Windows and Apple Mac OS X. HeatmapGenerator is released under the GNU General Public License and publicly available at: http://sourceforge.net/projects/heatmapgenerator/. The Mac OS X direct download is available at: http://sourceforge.net/projects/heatmapgenerator/files/HeatmapGenerator_MAC_OSX.tar.gz/download. The Windows OS direct download is available at: http://sourceforge.net/projects/heatmapgenerator/files/HeatmapGenerator_WINDOWS.zip/download.

  11. Simple Web-based interactive key development software (WEBiKEY) and an example key for Kuruna (Poaceae: Bambusoideae)1

    PubMed Central

    Attigala, Lakshmi; De Silva, Nuwan I.; Clark, Lynn G.

    2016-01-01

    Premise of the study: Programs that are user-friendly and freely available for developing Web-based interactive keys are scarce and most of the well-structured applications are relatively expensive. WEBiKEY was developed to enable researchers to easily develop their own Web-based interactive keys with fewer resources. Methods and Results: A Web-based multiaccess identification tool (WEBiKEY) was developed that uses freely available Microsoft ASP.NET technologies and an SQL Server database for Windows-based hosting environments. WEBiKEY was tested for its usability with a sample data set, the temperate woody bamboo genus Kuruna (Poaceae). Conclusions: WEBiKEY is freely available to the public and can be used to develop Web-based interactive keys for any group of species. The interactive key we developed for Kuruna using WEBiKEY enables users to visually inspect characteristics of Kuruna and identify an unknown specimen as one of seven possible species in the genus. PMID:27144109

  12. Efficient processing of two-dimensional arrays with C or C++

    USGS Publications Warehouse

    Donato, David I.

    2017-07-20

    Because fast and efficient serial processing of raster-graphic images and other two-dimensional arrays is a requirement in land-change modeling and other applications, the effects of 10 factors on the runtimes for processing two-dimensional arrays with C and C++ are evaluated in a comparative factorial study. This study’s factors include the choice among three C or C++ source-code techniques for array processing; the choice of Microsoft Windows 7 or a Linux operating system; the choice of 4-byte or 8-byte array elements and indexes; and the choice of 32-bit or 64-bit memory addressing. This study demonstrates how programmer choices can reduce runtimes by 75 percent or more, even after compiler optimizations. Ten points of practical advice for faster processing of two-dimensional arrays are offered to C and C++ programmers. Further study and the development of a C and C++ software test suite are recommended.Key words: array processing, C, C++, compiler, computational speed, land-change modeling, raster-graphic image, two-dimensional array, software efficiency

  13. Automated Routines for Calculating Whole-Stream Metabolism: Theoretical Background and User's Guide

    USGS Publications Warehouse

    Bales, Jerad D.; Nardi, Mark R.

    2007-01-01

    In order to standardize methods and facilitate rapid calculation and archival of stream-metabolism variables, the Stream Metabolism Program was developed to calculate gross primary production, net ecosystem production, respiration, and selected other variables from continuous measurements of dissolved-oxygen concentration, water temperature, and other user-supplied information. Methods for calculating metabolism from continuous measurements of dissolved-oxygen concentration and water temperature are fairly well known, but a standard set of procedures and computation software for all aspects of the calculations were not available previously. The Stream Metabolism Program addresses this deficiency with a stand-alone executable computer program written in Visual Basic.NET?, which runs in the Microsoft Windows? environment. All equations and assumptions used in the development of the software are documented in this report. Detailed guidance on application of the software is presented, along with a summary of the data required to use the software. Data from either a single station or paired (upstream, downstream) stations can be used with the software to calculate metabolism variables.

  14. Automated Diagnosis Of Conditions In A Plant-Growth Chamber

    NASA Technical Reports Server (NTRS)

    Clinger, Barry R.; Damiano, Alfred L.

    1995-01-01

    Biomass Production Chamber Operations Assistant software and hardware constitute expert system that diagnoses mechanical failures in controlled-environment hydroponic plant-growth chamber and recommends corrective actions to be taken by technicians. Subjects of continuing research directed toward development of highly automated closed life-support systems aboard spacecraft to process animal (including human) and plant wastes into food and oxygen. Uses Microsoft Windows interface to give technicians intuitive, efficient access to critical data. In diagnostic mode, system prompts technician for information. When expert system has enough information, it generates recovery plan.

  15. MEGA X: Molecular Evolutionary Genetics Analysis across Computing Platforms.

    PubMed

    Kumar, Sudhir; Stecher, Glen; Li, Michael; Knyaz, Christina; Tamura, Koichiro

    2018-06-01

    The Molecular Evolutionary Genetics Analysis (Mega) software implements many analytical methods and tools for phylogenomics and phylomedicine. Here, we report a transformation of Mega to enable cross-platform use on Microsoft Windows and Linux operating systems. Mega X does not require virtualization or emulation software and provides a uniform user experience across platforms. Mega X has additionally been upgraded to use multiple computing cores for many molecular evolutionary analyses. Mega X is available in two interfaces (graphical and command line) and can be downloaded from www.megasoftware.net free of charge.

  16. Artificial intelligence, neural network, and Internet tool integration in a pathology workstation to improve information access

    NASA Astrophysics Data System (ADS)

    Sargis, J. C.; Gray, W. A.

    1999-03-01

    The APWS allows user friendly access to several legacy systems which would normally each demand domain expertise for proper utilization. The generalized model, including objects, classes, strategies and patterns is presented. The core components of the APWS are the Microsoft Windows 95 Operating System, Oracle, Oracle Power Objects, Artificial Intelligence tools, a medical hyperlibrary and a web site. The paper includes a discussion of how could be automated by taking advantage of the expert system, object oriented programming and intelligent relational database tools within the APWS.

  17. [Automated anesthesia record system].

    PubMed

    Zhu, Tao; Liu, Jin

    2005-12-01

    Based on Client/Server architecture, a software of automated anesthesia record system running under Windows operation system and networks has been developed and programmed with Microsoft Visual C++ 6.0, Visual Basic 6.0 and SQL Server. The system can deal with patient's information throughout the anesthesia. It can collect and integrate the data from several kinds of medical equipment such as monitor, infusion pump and anesthesia machine automatically and real-time. After that, the system presents the anesthesia sheets automatically. The record system makes the anesthesia record more accurate and integral and can raise the anesthesiologist's working efficiency.

  18. McStas 1.7 - a new version of the flexible Monte Carlo neutron scattering package

    NASA Astrophysics Data System (ADS)

    Willendrup, Peter; Farhi, Emmanuel; Lefmann, Kim

    2004-07-01

    Current neutron instrumentation is both complex and expensive, and accurate simulation has become essential both for building new instruments and for using them effectively. The McStas neutron ray-trace simulation package is a versatile tool for producing such simulations, developed in collaboration between Risø and ILL. The new version (1.7) has many improvements, among these added support for the popular Microsoft Windows platform. This presentation will demonstrate a selection of the new features through a simulation of the ILL IN6 beamline.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roger Lew; Ronald L. Boring; Thomas A. Ulrich

    Operators of critical processes, such as nuclear power production, must contend with highly complex systems, procedures, and regulations. Developing human-machine interfaces (HMIs) that better support operators is a high priority for ensuring the safe and reliable operation of critical processes. Human factors engineering (HFE) provides a rich and mature set of tools for evaluating the performance of HMIs, but the set of tools for developing and designing HMIs is still in its infancy. Here we propose that Microsoft Windows Presentation Foundation (WPF) is well suited for many roles in the research and development of HMIs for process control.

  20. EVALIDatorReports: Reporting beyond the FIADB

    Treesearch

    Patrick D. Miles

    2009-01-01

    Tools for analyzing data collected by the U.S. Forest Service's Forest Inventory and Analysis (FIA) program are available in Microsoft Access© format. Databases have been created for every state, except Hawaii, and are available for downloading. EVALIDatorReports is a Visual Basic Application that is stored within each Microsoft Access© database...

  1. The Web-Database Connection Tools for Sharing Information on the Campus Intranet.

    ERIC Educational Resources Information Center

    Thibeault, Nancy E.

    This paper evaluates four tools for creating World Wide Web pages that interface with Microsoft Access databases: DB Gateway, Internet Database Assistant (IDBA), Microsoft Internet Database Connector (IDC), and Cold Fusion. The system requirements and features of each tool are discussed. A sample application, "The Virtual Help Desk"…

  2. EasyModeller: A graphical interface to MODELLER

    PubMed Central

    2010-01-01

    Background MODELLER is a program for automated protein Homology Modeling. It is one of the most widely used tool for homology or comparative modeling of protein three-dimensional structures, but most users find it a bit difficult to start with MODELLER as it is command line based and requires knowledge of basic Python scripting to use it efficiently. Findings The study was designed with an aim to develop of "EasyModeller" tool as a frontend graphical interface to MODELLER using Perl/Tk, which can be used as a standalone tool in windows platform with MODELLER and Python preinstalled. It helps inexperienced users to perform modeling, assessment, visualization, and optimization of protein models in a simple and straightforward way. Conclusion EasyModeller provides a graphical straight forward interface and functions as a stand-alone tool which can be used in a standard personal computer with Microsoft Windows as the operating system. PMID:20712861

  3. Real-time image reconstruction and display system for MRI using a high-speed personal computer.

    PubMed

    Haishi, T; Kose, K

    1998-09-01

    A real-time NMR image reconstruction and display system was developed using a high-speed personal computer and optimized for the 32-bit multitasking Microsoft Windows 95 operating system. The system was operated at various CPU clock frequencies by changing the motherboard clock frequency and the processor/bus frequency ratio. When the Pentium CPU was used at the 200 MHz clock frequency, the reconstruction time for one 128 x 128 pixel image was 48 ms and that for the image display on the enlarged 256 x 256 pixel window was about 8 ms. NMR imaging experiments were performed with three fast imaging sequences (FLASH, multishot EPI, and one-shot EPI) to demonstrate the ability of the real-time system. It was concluded that in most cases, high-speed PC would be the best choice for the image reconstruction and display system for real-time MRI. Copyright 1998 Academic Press.

  4. Teaching Simulation and Computer-Aided Separation Optimization in Liquid Chromatography by Means of Illustrative Microsoft Excel Spreadsheets

    ERIC Educational Resources Information Center

    Fasoula, S.; Nikitas, P.; Pappa-Louisi, A.

    2017-01-01

    A series of Microsoft Excel spreadsheets were developed to simulate the process of separation optimization under isocratic and simple gradient conditions. The optimization procedure is performed in a stepwise fashion using simple macros for an automatic application of this approach. The proposed optimization approach involves modeling of the peak…

  5. Optimizing and controlling earthmoving operations using spatial technologies

    NASA Astrophysics Data System (ADS)

    Alshibani, Adel

    This thesis presents a model designed for optimizing, tracking, and controlling earthmoving operations. The proposed model utilizes, Genetic Algorithm (GA), Linear Programming (LP), and spatial technologies including Global Positioning Systems (GPS) and Geographic Information Systems (GIS) to support the management functions of the developed model. The model assists engineers and contractors in selecting near optimum crew formations in planning phase and during construction, using GA and LP supported by the Pathfinder Algorithm developed in a GIS environment. GA is used in conjunction with a set of rules developed to accelerate the optimization process and to avoid generating and evaluating hypothetical and unrealistic crew formations. LP is used to determine quantities of earth to be moved from different borrow pits and to be placed at different landfill sites to meet project constraints and to minimize the cost of these earthmoving operations. On the one hand, GPS is used for onsite data collection and for tracking construction equipment in near real-time. On the other hand, GIS is employed to automate data acquisition and to analyze the collected spatial data. The model is also capable of reconfiguring crew formations dynamically during the construction phase while site operations are in progress. The optimization of the crew formation considers: (1) construction time, (2) construction direct cost, or (3) construction total cost. The model is also capable of generating crew formations to meet, as close as possible, specified time and/or cost constraints. In addition, the model supports tracking and reporting of project progress utilizing the earned-value concept and the project ratio method with modifications that allow for more accurate forecasting of project time and cost at set future dates and at completion. The model is capable of generating graphical and tabular reports. The developed model has been implemented in prototype software, using Object-Oriented Programming, Microsoft Foundation Classes (MFC), and has been coded using visual C++ V.6. Microsoft Access is employed as database management system. The developed software operates in Microsoft windows' environment. Three example applications were analyzed to validate the development made and to illustrate the essential features of the developed model.

  6. Understanding the Degrees of Freedom of Sample Variance by Using Microsoft Excel

    ERIC Educational Resources Information Center

    Ding, Jian-Hua; Jin, Xian-Wen; Shuai, Ling-Ying

    2017-01-01

    In this article, the degrees of freedom of the sample variance are simulated by using the Visual Basic for Applications of Microsoft Excel 2010. The simulation file dynamically displays why the sample variance should be calculated by dividing the sum of squared deviations by n-1 rather than n, which is helpful for students to grasp the meaning of…

  7. Microsoft excel spreadsheets for calculation of P-V-T relations and thermodynamic properties from equations of state of MgO, diamond and nine metals as pressure markers in high-pressure and high-temperature experiments

    NASA Astrophysics Data System (ADS)

    Sokolova, Tatiana S.; Dorogokupets, Peter I.; Dymshits, Anna M.; Danilov, Boris S.; Litasov, Konstantin D.

    2016-09-01

    We present Microsoft Excel spreadsheets for calculation of thermodynamic functions and P-V-T properties of MgO, diamond and 9 metals, Al, Cu, Ag, Au, Pt, Nb, Ta, Mo, and W, depending on temperature and volume or temperature and pressure. The spreadsheets include the most common pressure markers used in in situ experiments with diamond anvil cell and multianvil techniques. The calculations are based on the equation of state formalism via the Helmholtz free energy. The program was developed using Visual Basic for Applications in Microsoft Excel and is a time-efficient tool to evaluate volume, pressure and other thermodynamic functions using T-P and T-V data only as input parameters. This application is aimed to solve practical issues of high pressure experiments in geosciences and mineral physics.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wahanani, Nursinta Adi, E-mail: sintaadi@batan.go.id; Natsir, Khairina, E-mail: sintaadi@batan.go.id; Hartini, Entin, E-mail: sintaadi@batan.go.id

    Data processing software packages such as VSOP and MCNPX are softwares that has been scientifically proven and complete. The result of VSOP and MCNPX are huge and complex text files. In the analyze process, user need additional processing like Microsoft Excel to show informative result. This research develop an user interface software for output of VSOP and MCNPX. VSOP program output is used to support neutronic analysis and MCNPX program output is used to support burn-up analysis. Software development using iterative development methods which allow for revision and addition of features according to user needs. Processing time with this softwaremore » 500 times faster than with conventional methods using Microsoft Excel. PYTHON is used as a programming language, because Python is available for all major operating systems: Windows, Linux/Unix, OS/2, Mac, Amiga, among others. Values that support neutronic analysis are k-eff, burn-up and mass Pu{sup 239} and Pu{sup 241}. Burn-up analysis used the mass inventory values of actinide (Thorium, Plutonium, Neptunium and Uranium). Values are visualized in graphical shape to support analysis.« less

  9. IRiS: construction of ARG networks at genomic scales.

    PubMed

    Javed, Asif; Pybus, Marc; Melé, Marta; Utro, Filippo; Bertranpetit, Jaume; Calafell, Francesc; Parida, Laxmi

    2011-09-01

    Given a set of extant haplotypes IRiS first detects high confidence recombination events in their shared genealogy. Next using the local sequence topology defined by each detected event, it integrates these recombinations into an ancestral recombination graph. While the current system has been calibrated for human population data, it is easily extendible to other species as well. IRiS (Identification of Recombinations in Sequences) binary files are available for non-commercial use in both Linux and Microsoft Windows, 32 and 64 bit environments from https://researcher.ibm.com/researcher/view_project.php?id = 2303 parida@us.ibm.com.

  10. Microsoft health patient journey demonstrator.

    PubMed

    Disse, Kirsten

    2008-01-01

    As health care becomes more reliant on electronic systems, there is a need to standardise display elements to promote patient safety and clinical efficiency. The Microsoft Health Common User Interface (MSCUI) programme, developed by Microsoft and the National Health Service (NHS) was born out of this need and creates guidance and controls designed to increase patient safety and clinical effectiveness through consistent interface treatments. The Microsoft Health Patient Journey Demonstrator is a prototype tool designed to provide exemplar implementations of MSCUI guidance on a Microsoft platform. It is a targeted glimpse at a visual interface for the integration of health-relevant information, including electronic medical records. We built the demonstrator in Microsoft Silverlight 2, our application technology which brings desktop functionality and enriched levels of user experience to health settings worldwide via the internet. We based the demonstrator on an easily recognisable clinical scenario which offered us the most scope for demonstrating MSCUI guidance and innovation. The demonstrator is structured in three sections (administration, primary care and secondary care) each of which illustrates the activities associated within the setting relevant to our scenario. The demonstrator is published on the MSCUI website www.mscui.net The MSCUI patient journey demonstrator has been successful in raising awareness and increasing interest in the CUI programme.

  11. A Robust Function to Return the Cumulative Density of Non-Central F Distributions in Microsoft Office Excel

    ERIC Educational Resources Information Center

    Nelson, James Byron

    2016-01-01

    The manuscript presents a Visual Basic[superscript R] for Applications function that operates within Microsoft Office Excel[superscript R] to return the area below the curve for a given F within a specified non-central F distribution. The function will be of use to Excel users without programming experience wherever a non-central F distribution is…

  12. Marker-less respiratory motion modeling using the Microsoft Kinect for Windows

    NASA Astrophysics Data System (ADS)

    Tahavori, F.; Alnowami, M.; Wells, K.

    2014-03-01

    Patient respiratory motion is a major problem during external beam radiotherapy of the thoracic and abdominal regions due to the associated organ and target motion. In addition, such motion introduces uncertainty in both radiotherapy planning and delivery and may potentially vary between the planning and delivery sessions. The aim of this work is to examine subject-specific external respiratory motion and its associated drift from an assumed average cycle which is the basis for many respiratory motion compensated applications including radiotherapy treatment planning and delivery. External respiratory motion data were acquired from a group of 20 volunteers using a marker-less 3D depth camera, Kinect for Windows. The anterior surface encompassing thoracic and abdominal regions were subject to principal component analysis (PCA) to investigate dominant variations. The first principal component typically describes more than 70% of the motion data variance in the thoracic and abdominal surfaces. Across all of the subjects used in this study, 58% of subjects demonstrate largely abdominal breathing and 33% exhibited largely thoracic dominated breathing. In most cases there is observable drift in respiratory motion during the 300s capture period, which is visually demonstrated using Kernel Density Estimation. This study demonstrates that for this cohort of apparently healthy volunteers, there is significant respiratory motion drift in most cases, in terms of amplitude and relative displacement between the thoracic and abdominal respiratory components. This has implications for the development of effective motion compensation methodology.

  13. uSIMPK. An Excel for Windows-based simulation program for instruction of basic pharmacokinetics principles to pharmacy students.

    PubMed

    Brocks, Dion R

    2015-07-01

    Pharmacokinetics can be a challenging topic to teach due to the complex relationships inherent between physiological parameters, mathematical descriptors and equations, and their combined impact on shaping the blood fluid concentration vs. time curves of drugs. A computer program was developed within Microsoft Excel for Windows, designed to assist in the instruction of basic pharmacokinetics within an entry-to-practice pharmacy class environment. The program is composed of a series of spreadsheets (modules) linked by Visual Basic for Applications, intended to illustrate the relationships between pharmacokinetic and in some cases physiological parameters, doses and dose rates and the drug blood fluid concentration vs. time curves. Each module is accompanied by a simulation user's guide, prompting the user to change specific independent parameters and then observe the impact of the change(s) on the drug concentration vs. time curve and on other dependent parameters. "Slider" (or "scroll") bars can be selected to readily see the effects of repeated changes on the dependencies. Topics covered include one compartment single dose administration (iv bolus, oral, short infusion), intravenous infusion, repeated doses, renal and hepatic clearance, nonlinear elimination, two compartment model, plasma protein binding and the relationship between pharmacokinetics and drug effect. The program has been used in various forms in the classroom over a number of years, with positive ratings generally being received from students for its use in the classroom. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  14. CIS4/403: Design and Implementation of an Intranet-based system for Real-Time Tele-Consultation in Oncology

    PubMed Central

    Eccher, C; Berloffa, F; Demichelis, F; Larcher, B; Galvagni, M; Sboner, A; Graiff, A; Forti, S

    1999-01-01

    Introduction This study describes a tele-consultation system (TCS) developed to provide a computing environment over a Wide Area Network (WAN) in North Italy (Province of Trento), that can be used by two or more physicians to share medical data and to work co-operatively on medical records. A pilot study has been carried out in oncology to assess the effectiveness of the system. The aim of this project is to facilitate the management of oncology patients by improving communication among the specialists of central and district hospitals. Methods and Results The TCS is an Intranet-based solution. The Intranet is based on a PC WAN with Windows NT Server, Microsoft SQL Server, and Internet Information Server. TCS is composed of native and custom applications developed in the Microsoft Windows (9x and NT) environment. The basic component of the system is the multimedia digital medical record, structured as a collection of HTML and ASP pages. A distributed relational database will allow users to store and retrieve medical records, accessed by a dedicated Web browser via the Web Server. The medical data to be stored and the presentation architecture of the clinical record had been determined in close collaboration with the clinicians involved in the project. TCS will allow a multi-point tele-consultation (TC) among two or more participants on remote computers, providing synchronized surfing through the clinical report. A set of collaborative and personal tools, whiteboard with drawing tools, point-to-point digital audio-conference, chat, local notepad, e-mail service, are integrated in the system to provide an user friendly environment. TCS has been developed as a client-server architecture. The client part of the system is based on the Microsoft Web Browser control and provides the user interface and the tools described above. The server part, running all the time on a dedicated computer, accepts connection requests and manages the connections among the participants in a TC, allowing multiple TC to run simultaneously. TCS has been developed in Visual C++ environment using MFC library and COM technology; ActiveX controls have been written in Visual Basic to perform dedicated tasks from the inside of the HTML clinical report. Before deploying the system in the hospital departments involved in the project, TCS has been tested in our laboratory by clinicians involved in the project to evaluate the usability of the system. Discussion TCS has the potential to support a "multi-disciplinary distributed virtual oncological meeting". The specialists of different departments and of different hospitals can attend "virtual meetings" and interactively discuss on medical data. An expected benefit of the "virtual meeting" should be the possibility to provide expert remote advice from oncologists to peripheral cancer units in formulating treatment plans, conducting follow-up sessions and supporting clinical research.

  15. LICSS - a chemical spreadsheet in microsoft excel

    PubMed Central

    2012-01-01

    Background Representations of chemical datasets in spreadsheet format are important for ready data assimilation and manipulation. In addition to the normal spreadsheet facilities, chemical spreadsheets need to have visualisable chemical structures and data searchable by chemical as well as textual queries. Many such chemical spreadsheet tools are available, some operating in the familiar Microsoft Excel environment. However, within this group, the performance of Excel is often compromised, particularly in terms of the number of compounds which can usefully be stored on a sheet. Summary LICSS is a lightweight chemical spreadsheet within Microsoft Excel for Windows. LICSS stores structures solely as Smiles strings. Chemical operations are carried out by calling Java code modules which use the CDK, JChemPaint and OPSIN libraries to provide cheminformatics functionality. Compounds in sheets or charts may be visualised (individually or en masse), and sheets may be searched by substructure or similarity. All the molecular descriptors available in CDK may be calculated for compounds (in batch or on-the-fly), and various cheminformatic operations such as fingerprint calculation, Sammon mapping, clustering and R group table creation may be carried out. We detail here the features of LICSS and how they are implemented. We also explain the design criteria, particularly in terms of potential corporate use, which led to this particular implementation. Conclusions LICSS is an Excel-based chemical spreadsheet with a difference: • It can usefully be used on sheets containing hundreds of thousands of compounds; it doesn't compromise the normal performance of Microsoft Excel • It is designed to be installed and run in environments in which users do not have admin privileges; installation involves merely file copying, and sharing of LICSS sheets invokes automatic installation • It is free and extensible LICSS is open source software and we hope sufficient detail is provided here to enable developers to add their own features and share with the community. PMID:22301088

  16. LICSS - a chemical spreadsheet in microsoft excel.

    PubMed

    Lawson, Kevin R; Lawson, Jonty

    2012-02-02

    Representations of chemical datasets in spreadsheet format are important for ready data assimilation and manipulation. In addition to the normal spreadsheet facilities, chemical spreadsheets need to have visualisable chemical structures and data searchable by chemical as well as textual queries. Many such chemical spreadsheet tools are available, some operating in the familiar Microsoft Excel environment. However, within this group, the performance of Excel is often compromised, particularly in terms of the number of compounds which can usefully be stored on a sheet. LICSS is a lightweight chemical spreadsheet within Microsoft Excel for Windows. LICSS stores structures solely as Smiles strings. Chemical operations are carried out by calling Java code modules which use the CDK, JChemPaint and OPSIN libraries to provide cheminformatics functionality. Compounds in sheets or charts may be visualised (individually or en masse), and sheets may be searched by substructure or similarity. All the molecular descriptors available in CDK may be calculated for compounds (in batch or on-the-fly), and various cheminformatic operations such as fingerprint calculation, Sammon mapping, clustering and R group table creation may be carried out.We detail here the features of LICSS and how they are implemented. We also explain the design criteria, particularly in terms of potential corporate use, which led to this particular implementation. LICSS is an Excel-based chemical spreadsheet with a difference:• It can usefully be used on sheets containing hundreds of thousands of compounds; it doesn't compromise the normal performance of Microsoft Excel• It is designed to be installed and run in environments in which users do not have admin privileges; installation involves merely file copying, and sharing of LICSS sheets invokes automatic installation• It is free and extensibleLICSS is open source software and we hope sufficient detail is provided here to enable developers to add their own features and share with the community.

  17. CoalVal-A coal resource valuation program

    USGS Publications Warehouse

    Rohrbacher, Timothy J.; McIntosh, Gary E.

    2010-01-01

    CoalVal is a menu-driven Windows program that produces cost-of-mining analyses of mine-modeled coal resources. Geological modeling of the coal beds and some degree of mine planning, from basic prefeasibility to advanced, must already have been performed before this program can be used. United States Geological Survey mine planning is done from a very basic, prefeasibility standpoint, but the accuracy of CoalVal's output is a reflection of the accuracy of the data entered, both for mine costs and mine planning. The mining cost analysis is done by using mine cost models designed for the commonly employed, surface and underground mining methods utilized in the United States. CoalVal requires a Microsoft Windows? 98 or Windows? XP operating system and a minimum of 1 gigabyte of random access memory to perform operations. It will not operate on Microsoft Vista?, Windows? 7, or Macintosh? operating systems. The program will summarize the evaluation of an unlimited number of coal seams, haulage zones, tax entities, or other area delineations for a given coal property, coalfield, or basin. When the reader opens the CoalVal publication from the USGS website, options are provided to download the CoalVal publication manual and the CoalVal Program. The CoalVal report is divided into five specific areas relevant to the development and use of the CoalVal program: 1. Introduction to CoalVal Assumptions and Concepts. 2. Mine Model Assumption Details (appendix A). 3. CoalVal Project Tutorial (appendix B). 4. Program Description (appendix C). 5. Mine Model and Discounted Cash Flow Formulas (appendix D). The tutorial explains how to enter coal resource and quality data by mining method; program default values for production, operating, and cost variables; and ones own operating and cost variables into the program. Generated summary reports list the volume of resource in short tons available for mining, recoverable short tons by mining method; the seam or property being mined; operating cost per ton; and discounted cash flow cost per ton to mine and process the resources. Costs are calculated as loaded in a unit train, free-on-board the tipple, at a rate of return prescribed by the evaluator. The recoverable resources (in short tons) may be grouped by incremental cost over any range chosen by the user. For example, in the Gillette coalfield evaluation, the discounted cash flow mining cost (at an 8 percent rate of return) and its associated tonnage may be grouped by any applicable increment (for example, $0.10 per ton, $0.20 per ton, and so on) and using any dollar per ton range that is desired (for example, from $4.00 per ton to $15.00 per ton). This grouping ability allows the user to separate the coal reserves from the nonreserve resources and to construct cost curves to determine the effects of coal market fluctuations on the availability of coal for fuel whether for the generation of electricity or for coal-to-liquids processes. Coking coals are not addressed in this report.

  18. Xyce Parallel Electronic Simulator Reference Guide Version 6.4

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keiter, Eric R.; Mei, Ting; Russo, Thomas V.

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users' Guide [1] . The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce . This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users' Guide [1] . Trademarks The information herein is subject to change without notice. Copyright c 2002-2015 Sandia Corporation. All rights reserved. Xyce TM Electronic Simulator and Xyce TMmore » are trademarks of Sandia Corporation. Portions of the Xyce TM code are: Copyright c 2002, The Regents of the University of California. Produced at the Lawrence Livermore National Laboratory. Written by Alan Hindmarsh, Allan Taylor, Radu Serban. UCRL-CODE-2002-59 All rights reserved. Orcad, Orcad Capture, PSpice and Probe are registered trademarks of Cadence Design Systems, Inc. Microsoft, Windows and Windows 7 are registered trademarks of Microsoft Corporation. Medici, DaVinci and Taurus are registered trademarks of Synopsys Corporation. Amtec and TecPlot are trademarks of Amtec Engineering, Inc. Xyce 's expression library is based on that inside Spice 3F5 developed by the EECS Department at the University of California. The EKV3 MOSFET model was developed by the EKV Team of the Electronics Laboratory-TUC of the Technical University of Crete. All other trademarks are property of their respective owners. Contacts Bug Reports (Sandia only) http://joseki.sandia.gov/bugzilla http://charleston.sandia.gov/bugzilla World Wide Web http://xyce.sandia.gov http://charleston.sandia.gov/xyce (Sandia only) Email xyce@sandia.gov (outside Sandia) xyce-sandia@sandia.gov (Sandia only)« less

  19. SPICODYN: A Toolbox for the Analysis of Neuronal Network Dynamics and Connectivity from Multi-Site Spike Signal Recordings.

    PubMed

    Pastore, Vito Paolo; Godjoski, Aleksandar; Martinoia, Sergio; Massobrio, Paolo

    2018-01-01

    We implemented an automated and efficient open-source software for the analysis of multi-site neuronal spike signals. The software package, named SPICODYN, has been developed as a standalone windows GUI application, using C# programming language with Microsoft Visual Studio based on .NET framework 4.5 development environment. Accepted input data formats are HDF5, level 5 MAT and text files, containing recorded or generated time series spike signals data. SPICODYN processes such electrophysiological signals focusing on: spiking and bursting dynamics and functional-effective connectivity analysis. In particular, for inferring network connectivity, a new implementation of the transfer entropy method is presented dealing with multiple time delays (temporal extension) and with multiple binary patterns (high order extension). SPICODYN is specifically tailored to process data coming from different Multi-Electrode Arrays setups, guarantying, in those specific cases, automated processing. The optimized implementation of the Delayed Transfer Entropy and the High-Order Transfer Entropy algorithms, allows performing accurate and rapid analysis on multiple spike trains from thousands of electrodes.

  20. Enhanced, Partially Redundant Emergency Notification System

    NASA Technical Reports Server (NTRS)

    Pounds, Clark D.

    2005-01-01

    The Johnson Space Center Emergency Notification System (JENS) software utilizes pre-existing computation and communication infrastructure to augment a prior variable-tone, siren-based, outdoor alarm system, in order to enhance the ability to give notice of emergencies to employees working in multiple buildings. The JENS software includes a component that implements an administrative Web site. Administrators can grant and deny access to the administrative site and to an originator Web site that enables authorized individuals to quickly compose and issue alarms. The originator site also facilitates maintenance and review of alarms already issued. A custom client/server application program enables an originator to notify every user who is logged in on a Microsoft Windows-based desktop computer by means of a pop-up message that interrupts, but does not disrupt, the user s work. Alternatively or in addition, the originator can send an alarm message to recipients on an e-mail distribution list and/or can post the notice on an internal Web site. An alarm message can consist of (1) text describing the emergency and suggesting a course of action and (2) a replica of the corresponding audible outdoor alarm.

  1. Managing Attribute—Value Clinical Trials Data Using the ACT/DB Client—Server Database System

    PubMed Central

    Nadkarni, Prakash M.; Brandt, Cynthia; Frawley, Sandra; Sayward, Frederick G.; Einbinder, Robin; Zelterman, Daniel; Schacter, Lee; Miller, Perry L.

    1998-01-01

    ACT/DB is a client—server database application for storing clinical trials and outcomes data, which is currently undergoing initial pilot use. It stores most of its data in entity—attribute—value form. Such data are segregated according to data type to allow indexing by value when possible, and binary large object data are managed in the same way as other data. ACT/DB lets an investigator design a study rapidly by defining the parameters (or attributes) that are to be gathered, as well as their logical grouping for purposes of display and data entry. ACT/DB generates customizable data entry. The data can be viewed through several standard reports as well as exported as text to external analysis programs. ACT/DB is designed to encourage reuse of parameters across multiple studies and has facilities for dictionary search and maintenance. It uses a Microsoft Access client running on Windows 95 machines, which communicates with an Oracle server running on a UNIX platform. ACT/DB is being used to manage the data for seven studies in its initial deployment. PMID:9524347

  2. [Development of analysis software package for the two kinds of Japanese fluoro-d-glucose-positron emission tomography guideline].

    PubMed

    Matsumoto, Keiichi; Endo, Keigo

    2013-06-01

    Two kinds of Japanese guidelines for the data acquisition protocol of oncology fluoro-D-glucose-positron emission tomography (FDG-PET)/computed tomography (CT) scans were created by the joint task force of the Japanese Society of Nuclear Medicine Technology (JSNMT) and the Japanese Society of Nuclear Medicine (JSNM), and published in Kakuigaku-Gijutsu 27(5): 425-456, 2007 and 29(2): 195-235, 2009. These guidelines aim to standardize PET image quality among facilities and different PET/CT scanner models. The objective of this study was to develop a personal computer-based performance measurement and image quality processor for the two kinds of Japanese guidelines for oncology (18)F-FDG PET/CT scans. We call this software package the "PET quality control tool" (PETquact). Microsoft Corporation's Windows(™) is used as the operating system for PETquact, which requires 1070×720 image resolution and includes 12 different applications. The accuracy was examined for numerous applications of PETquact. For example, in the sensitivity application, the system sensitivity measurement results were equivalent when comparing two PET sinograms obtained from the PETquact and the report. PETquact is suited for analysis of the two kinds of Japanese guideline, and it shows excellent spec to performance measurements and image quality analysis. PETquact can be used at any facility if the software package is installed on a laptop computer.

  3. An Interactive Microsoft(registered tm) Excel Program for Tracking a Single Evaporating Droplet in Crossflow

    NASA Technical Reports Server (NTRS)

    Liew, K. H.; Urip, E.; Yang, S. L.; Marek, C. J.

    2004-01-01

    Droplet interaction with a high temperature gaseous crossflow is important because of its wide application in systems involving two phase mixing such as in combustion requiring quick mixing of fuel and air with the reduction of pollutants and for jet mixing in the dilution zone of combustors. Therefore, the focus of this work is to investigate dispersion of a two-dimensional atomized and evaporating spray jet into a two-dimensional crossflow. An interactive Microsoft Excel program for tracking a single droplet in crossflow that has previously been developed will be modified to include droplet evaporation computation. In addition to the high velocity airflow, the injected droplets are also subjected to combustor temperature and pressure that affect their motion in the flow field. Six ordinary differential equations are then solved by 4th-order Runge-Kutta method using Microsoft Excel software. Microsoft Visual Basic programming and Microsoft Excel macrocode are used to produce the data and plot graphs describing the droplet's motion in the flow field. This program computes and plots the data sequentially without forcing the user to open other types of plotting programs. A user's manual on how to use the program is included.

  4. A Microsoft-Excel-based tool for running and critically appraising network meta-analyses--an overview and application of NetMetaXL.

    PubMed

    Brown, Stephen; Hutton, Brian; Clifford, Tammy; Coyle, Doug; Grima, Daniel; Wells, George; Cameron, Chris

    2014-09-29

    The use of network meta-analysis has increased dramatically in recent years. WinBUGS, a freely available Bayesian software package, has been the most widely used software package to conduct network meta-analyses. However, the learning curve for WinBUGS can be daunting, especially for new users. Furthermore, critical appraisal of network meta-analyses conducted in WinBUGS can be challenging given its limited data manipulation capabilities and the fact that generation of graphical output from network meta-analyses often relies on different software packages than the analyses themselves. We developed a freely available Microsoft-Excel-based tool called NetMetaXL, programmed in Visual Basic for Applications, which provides an interface for conducting a Bayesian network meta-analysis using WinBUGS from within Microsoft Excel. . This tool allows the user to easily prepare and enter data, set model assumptions, and run the network meta-analysis, with results being automatically displayed in an Excel spreadsheet. It also contains macros that use NetMetaXL's interface to generate evidence network diagrams, forest plots, league tables of pairwise comparisons, probability plots (rankograms), and inconsistency plots within Microsoft Excel. All figures generated are publication quality, thereby increasing the efficiency of knowledge transfer and manuscript preparation. We demonstrate the application of NetMetaXL using data from a network meta-analysis published previously which compares combined resynchronization and implantable defibrillator therapy in left ventricular dysfunction. We replicate results from the previous publication while demonstrating result summaries generated by the software. Use of the freely available NetMetaXL successfully demonstrated its ability to make running network meta-analyses more accessible to novice WinBUGS users by allowing analyses to be conducted entirely within Microsoft Excel. NetMetaXL also allows for more efficient and transparent critical appraisal of network meta-analyses, enhanced standardization of reporting, and integration with health economic evaluations which are frequently Excel-based.

  5. A Microsoft-Excel-based tool for running and critically appraising network meta-analyses—an overview and application of NetMetaXL

    PubMed Central

    2014-01-01

    Background The use of network meta-analysis has increased dramatically in recent years. WinBUGS, a freely available Bayesian software package, has been the most widely used software package to conduct network meta-analyses. However, the learning curve for WinBUGS can be daunting, especially for new users. Furthermore, critical appraisal of network meta-analyses conducted in WinBUGS can be challenging given its limited data manipulation capabilities and the fact that generation of graphical output from network meta-analyses often relies on different software packages than the analyses themselves. Methods We developed a freely available Microsoft-Excel-based tool called NetMetaXL, programmed in Visual Basic for Applications, which provides an interface for conducting a Bayesian network meta-analysis using WinBUGS from within Microsoft Excel. . This tool allows the user to easily prepare and enter data, set model assumptions, and run the network meta-analysis, with results being automatically displayed in an Excel spreadsheet. It also contains macros that use NetMetaXL’s interface to generate evidence network diagrams, forest plots, league tables of pairwise comparisons, probability plots (rankograms), and inconsistency plots within Microsoft Excel. All figures generated are publication quality, thereby increasing the efficiency of knowledge transfer and manuscript preparation. Results We demonstrate the application of NetMetaXL using data from a network meta-analysis published previously which compares combined resynchronization and implantable defibrillator therapy in left ventricular dysfunction. We replicate results from the previous publication while demonstrating result summaries generated by the software. Conclusions Use of the freely available NetMetaXL successfully demonstrated its ability to make running network meta-analyses more accessible to novice WinBUGS users by allowing analyses to be conducted entirely within Microsoft Excel. NetMetaXL also allows for more efficient and transparent critical appraisal of network meta-analyses, enhanced standardization of reporting, and integration with health economic evaluations which are frequently Excel-based. PMID:25267416

  6. Epi info - present and future.

    PubMed

    Su, Y; Yoon, S S

    2003-01-01

    Epi Info is a suite of public domain computer programs for public health professionals developed by the Centers for Disease Control and Prevention (CDC). Epi Info is used for rapid questionnaire design, data entry and validation, data analysis including mapping and graphing, and creation of reports. Epi Info was originally created in 1985 using Turbo Pascal. In 1998, the last version of Epi Info for DOS, version 6, was released. Epi Info for DOS is currently supported by CDC but is no longer updated. The current version, Epi Info 2002, is Windows-based software developed using Microsoft Visual Basic. Approximately 300,000 downloads of Epi Info software occurred in 2002 from approximately 130 countries. These numbers make Epi Info probably one of the most widely distributed and used public domain programs in the world. The DOS version of Epi Info was translated into 13 languages, and efforts are underway to translate the Windows version into other major languages. Versions already exist for Spanish, French, Portuguese, Chinese, Japanese, and Arabic.

  7. Enigma Version 12

    NASA Technical Reports Server (NTRS)

    Shores, David; Goza, Sharon P.; McKeegan, Cheyenne; Easley, Rick; Way, Janet; Everett, Shonn; Guerra, Mark; Kraesig, Ray; Leu, William

    2013-01-01

    Enigma Version 12 software combines model building, animation, and engineering visualization into one concise software package. Enigma employs a versatile user interface to allow average users access to even the most complex pieces of the application. Using Enigma eliminates the need to buy and learn several software packages to create an engineering visualization. Models can be created and/or modified within Enigma down to the polygon level. Textures and materials can be applied for additional realism. Within Enigma, these models can be combined to create systems of models that have a hierarchical relationship to one another, such as a robotic arm. Then these systems can be animated within the program or controlled by an external application programming interface (API). In addition, Enigma provides the ability to use plug-ins. Plugins allow the user to create custom code for a specific application and access the Enigma model and system data, but still use the Enigma drawing functionality. CAD files can be imported into Enigma and combined to create systems of computer graphics models that can be manipulated with constraints. An API is available so that an engineer can write a simulation and drive the computer graphics models with no knowledge of computer graphics. An animation editor allows an engineer to set up sequences of animations generated by simulations or by conceptual trajectories in order to record these to highquality media for presentation. Enigma Version 12 Lyndon B. Johnson Space Center, Houston, Texas 28 NASA Tech Briefs, September 2013 Planetary Protection Bioburden Analysis Program NASA's Jet Propulsion Laboratory, Pasadena, California This program is a Microsoft Access program that performed statistical analysis of the colony counts from assays performed on the Mars Science Laboratory (MSL) spacecraft to determine the bioburden density, 3-sigma biodensity, and the total bioburdens required for the MSL prelaunch reports. It also contains numerous tools that report the data in various ways to simplify the reports required. The program performs all the calculations directly in the MS Access program. Prior to this development, the data was exported to large Excel files that had to be cut and pasted to provide the desired results. The program contains a main menu and a number of submenus. Analyses can be performed by using either all the assays, or only the accountable assays that will be used in the final analysis. There are three options on the first menu: either calculate using (1) the old MER (Mars Exploration Rover) statistics, (2) the MSL statistics for all the assays, or This software implements penetration limit equations for common micrometeoroid and orbital debris (MMOD) shield configurations, windows, and thermal protection systems. Allowable MMOD risk is formulated in terms of the probability of penetration (PNP) of the spacecraft pressure hull. For calculating the risk, spacecraft geometry models, mission profiles, debris environment models, and penetration limit equations for installed shielding configurations are required. Risk assessment software such as NASA's BUMPERII is used to calculate mission PNP; however, they are unsuitable for use in shield design and preliminary analysis studies. The software defines a single equation for the design and performance evaluation of common MMOD shielding configurations, windows, and thermal protection systems, along with a description of their validity range and guidelines for their application. Recommendations are based on preliminary reviews of fundamental assumptions, and accuracy in predicting experimental impact test results. The software is programmed in Visual Basic for Applications for installation as a simple add-in for Microsoft Excel. The user is directed to a graphical user interface (GUI) that requires user inputs and provides solutions directly in Microsoft Excel workbooks. This work was done by Shannon Ryan of the USRA Lunar and Planetary Institute for Johnson Space Center. Further information is contained in a TSP (see page 1). MSC- 24582-1 Micrometeoroid and Orbital Debris (MMOD) Shield Ballistic Limit Analysis Program Lyndon B. Johnson Space Center, Houston, Texas Commercially, because it is so generic, Enigma can be used for almost any project that requires engineering visualization, model building, or animation. Models in Enigma can be exported to many other formats for use in other applications as well. Educationally, Enigma is being used to allow university students to visualize robotic algorithms in a simulation mode before using them with actual hardware.

  8. D Capturing Performances of Low-Cost Range Sensors for Mass-Market Applications

    NASA Astrophysics Data System (ADS)

    Guidi, G.; Gonizzi, S.; Micoli, L.

    2016-06-01

    Since the advent of the first Kinect as motion controller device for the Microsoft XBOX platform (November 2010), several similar active and low-cost range sensing devices have been introduced on the mass-market for several purposes, including gesture based interfaces, 3D multimedia interaction, robot navigation, finger tracking, 3D body scanning for garment design and proximity sensors for automotive. However, given their capability to generate a real time stream of range images, these has been used in some projects also as general purpose range devices, with performances that for some applications might be satisfying. This paper shows the working principle of the various devices, analyzing them in terms of systematic errors and random errors for exploring the applicability of them in standard 3D capturing problems. Five actual devices have been tested featuring three different technologies: i) Kinect V1 by Microsoft, Structure Sensor by Occipital, and Xtion PRO by ASUS, all based on different implementations of the Primesense sensor; ii) F200 by Intel/Creative, implementing the Realsense pattern projection technology; Kinect V2 by Microsoft, equipped with the Canesta TOF Camera. A critical analysis of the results tries first of all to compare them, and secondarily to focus the range of applications for which such devices could actually work as a viable solution.

  9. Application of visual basic in high-throughput mass spectrometry-directed purification of combinatorial libraries.

    PubMed

    Li, B; Chan, E C Y

    2003-01-01

    We present an approach to customize the sample submission process for high-throughput purification (HTP) of combinatorial parallel libraries using preparative liquid chromatography electrospray ionization mass spectrometry. In this study, Visual Basic and Visual Basic for Applications programs were developed using Microsoft Visual Basic 6 and Microsoft Excel 2000, respectively. These programs are subsequently applied for the seamless electronic submission and handling of data for HTP. Functions were incorporated into these programs where medicinal chemists can perform on-line verification of the purification status and on-line retrieval of postpurification data. The application of these user friendly and cost effective programs in our HTP technology has greatly increased our work efficiency by reducing paper work and manual manipulation of data.

  10. The personal receiving document management and the realization of email function in OAS

    NASA Astrophysics Data System (ADS)

    Li, Biqing; Li, Zhao

    2017-05-01

    This software is an independent software system, suitable for small and medium enterprises, contains personal office, scientific research project management and system management functions, independently run in relevant environment, and to solve practical needs. This software is an independent software system, using the current popular B/S (browser/server) structure and ASP.NET technology development, using the Windows 7 operating system, Microsoft SQL Server2005 Visual2008 and database as a development platform, suitable for small and medium enterprises, contains personal office, scientific research project management and system management functions, independently run in relevant environment, and to solve practical needs.

  11. A Mobile Computing Solution for Collecting Functional Analysis Data on a Pocket PC

    PubMed Central

    Jackson, James; Dixon, Mark R

    2007-01-01

    The present paper provides a task analysis for creating a computerized data system using a Pocket PC and Microsoft Visual Basic. With Visual Basic software and any handheld device running the Windows Moble operating system, this task analysis will allow behavior analysts to program and customize their own functional analysis data-collection system. The program will allow the user to select the type of behavior to be recorded, choose between interval and frequency data collection, and summarize data for graphing and analysis. We also provide suggestions for customizing the data-collection system for idiosyncratic research and clinical needs. PMID:17624078

  12. PyFDAP: automated analysis of fluorescence decay after photoconversion (FDAP) experiments.

    PubMed

    Bläßle, Alexander; Müller, Patrick

    2015-03-15

    We developed the graphical user interface PyFDAP for the fitting of linear and non-linear decay functions to data from fluorescence decay after photoconversion (FDAP) experiments. PyFDAP structures and analyses large FDAP datasets and features multiple fitting and plotting options. PyFDAP was written in Python and runs on Ubuntu Linux, Mac OS X and Microsoft Windows operating systems. The software, a user guide and a test FDAP dataset are freely available for download from http://people.tuebingen.mpg.de/mueller-lab. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  13. Layered virus protection for the operations and administrative messaging system

    NASA Technical Reports Server (NTRS)

    Cortez, R. H.

    2002-01-01

    NASA's Deep Space Network (DSN) is critical in supporting the wide variety of operating and plannedunmanned flight projects. For day-to-day operations it relies on email communication between the three Deep Space Communication Complexes (Canberra, Goldstone, Madrid) and NASA's Jet Propulsion Laboratory. The Operations & Administrative Messaging system, based on the Microsoft Windows NTand Exchange platform, provides the infrastructure that is required for reliable, mission-critical messaging. The reliability of this system, however, is threatened by the proliferation of email viruses that continue to spread at alarming rates. A layered approach to email security has been implemented across the DSN to protect against this threat.

  14. Architecture of the software for LAMOST fiber positioning subsystem

    NASA Astrophysics Data System (ADS)

    Peng, Xiaobo; Xing, Xiaozheng; Hu, Hongzhuan; Zhai, Chao; Li, Weimin

    2004-09-01

    The architecture of the software which controls the LAMOST fiber positioning sub-system is described. The software is composed of two parts as follows: a main control program in a computer and a unit controller program in a MCS51 single chip microcomputer ROM. And the function of the software includes: Client/Server model establishment, observation planning, collision handling, data transmission, pulse generation, CCD control, image capture and processing, and data analysis etc. Particular attention is paid to the ways in which different parts of the software can communicate. Also software techniques for multi threads, SOCKET programming, Microsoft Windows message response, and serial communications are discussed.

  15. Computer-Based Medical System

    NASA Technical Reports Server (NTRS)

    1998-01-01

    SYMED, Inc., developed a unique electronic medical records and information management system. The S2000 Medical Interactive Care System (MICS) incorporates both a comprehensive and interactive medical care support capability and an extensive array of digital medical reference materials in either text or high resolution graphic form. The system was designed, in cooperation with NASA, to improve the effectiveness and efficiency of physician practices. The S2000 is a MS (Microsoft) Windows based software product which combines electronic forms, medical documents, records management, and features a comprehensive medical information system for medical diagnostic support and treatment. SYMED, Inc. offers access to its medical systems to all companies seeking competitive advantages.

  16. The ISOLDE control system

    NASA Astrophysics Data System (ADS)

    Deloose, I.; Pace, A.

    1994-12-01

    The two CERN isotope separators named ISOLDE have been running on the new Personal Computer (PC) based control system since April 1992. The new architecture that makes heavy use of the commercial software and hardware of the PC market has been implemented on the 1700 geographically distributed control channels of the two separators and their experimental area. Eleven MSDOS Intel-based PCs with approximately 80 acquisition and control boards are used to access the equipment and are controlled from three PCs running Microsoft Windows used as consoles through a Novell Local Area Network. This paper describes the interesting solutions found and discusses the reduced programming workload and costs that have been obtained.

  17. 'Isotopo' a database application for facile analysis and management of mass isotopomer data.

    PubMed

    Ahmed, Zeeshan; Zeeshan, Saman; Huber, Claudia; Hensel, Michael; Schomburg, Dietmar; Münch, Richard; Eylert, Eva; Eisenreich, Wolfgang; Dandekar, Thomas

    2014-01-01

    The composition of stable-isotope labelled isotopologues/isotopomers in metabolic products can be measured by mass spectrometry and supports the analysis of pathways and fluxes. As a prerequisite, the original mass spectra have to be processed, managed and stored to rapidly calculate, analyse and compare isotopomer enrichments to study, for instance, bacterial metabolism in infection. For such applications, we provide here the database application 'Isotopo'. This software package includes (i) a database to store and process isotopomer data, (ii) a parser to upload and translate different data formats for such data and (iii) an improved application to process and convert signal intensities from mass spectra of (13)C-labelled metabolites such as tertbutyldimethylsilyl-derivatives of amino acids. Relative mass intensities and isotopomer distributions are calculated applying a partial least square method with iterative refinement for high precision data. The data output includes formats such as graphs for overall enrichments in amino acids. The package is user-friendly for easy and robust data management of multiple experiments. The 'Isotopo' software is available at the following web link (section Download): http://spp1316.uni-wuerzburg.de/bioinformatics/isotopo/. The package contains three additional files: software executable setup (installer), one data set file (discussed in this article) and one excel file (which can be used to convert data from excel to '.iso' format). The 'Isotopo' software is compatible only with the Microsoft Windows operating system. http://spp1316.uni-wuerzburg.de/bioinformatics/isotopo/. © The Author(s) 2014. Published by Oxford University Press.

  18. 75 FR 11841 - Repowering Assistance Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-12

    ... application window. SUMMARY: RBS is announcing a new application window to submit applications for the...-time application window for remaining FY 2009 funds. Paperwork Reduction Act In accordance with the... allocate all of the FY 2009 authorized funds. Therefore, the Agency is opening a new application window to...

  19. Micromechanical combined stress analysis: MICSTRAN, a user manual

    NASA Technical Reports Server (NTRS)

    Naik, R. A.

    1992-01-01

    Composite materials are currently being used in aerospace and other applications. The ability to tailor the composite properties by the appropriate selection of its constituents, the fiber and matrix, is a major advantage of composite materials. The Micromechanical Combined Stress Analysis (MICSTRAN) code provides the materials engineer with a user-friendly personal computer (PC) based tool to calculate overall composite properties given the constituent fiber and matrix properties. To assess the ability of the composite to carry structural loads, the materials engineer also needs to calculate the internal stresses in the composite material. MICSTRAN is a simple tool to calculate such internal stresses with a composite ply under combined thermomechanical loading. It assumes that the fibers have a circular cross-section and are arranged either in a repeating square or diamond array pattern within a ply. It uses a classical elasticity solution technique that has been demonstrated to calculate accurate stress results. Input to the program consists of transversely isotropic fiber properties and isotropic matrix properties such as moduli, Poisson's ratios, coefficients of thermal expansion, and volume fraction. Output consists of overall thermoelastic constants and stresses. Stresses can be computed under the combined action of thermal, transverse, longitudinal, transverse shear, and longitudinal shear loadings. Stress output can be requested along the fiber-matrix interface, the model boundaries, circular arcs, or at user-specified points located anywhere in the model. The MICSTRAN program is Windows compatible and takes advantage of the Microsoft Windows graphical user interface which facilitates multitasking and extends memory access far beyond the limits imposed by the DOS operating system.

  20. Quantification of color vision using a tablet display.

    PubMed

    Chacon, Alicia; Rabin, Jeff; Yu, Dennis; Johnston, Shawn; Bradshaw, Timothy

    2015-01-01

    Accurate color vision is essential for optimal performance in aviation and space environments using nonredundant color coding to convey critical information. Most color tests detect color vision deficiency (CVD) but fail to diagnose type or severity of CVD, which are important to link performance to occupational demands. The computer-based Cone Contrast Test (CCT) diagnoses type and severity of CVD. It is displayed on a netbook computer for clinical application, but a more portable version may prove useful for deployments, space and aviation cockpits, as well as accident and sports medicine settings. Our purpose was to determine if the CCT can be conducted on a tablet display (Windows 8, Microsoft, Seattle, WA) using touch-screen response input. The CCT presents colored letters visible only to red (R), green (G), and blue (B) sensitive retinal cones to determine the lowest R, G, and B cone contrast visible to the observer. The CCT was measured in 16 color vision normals (CVN) and 16 CVDs using the standard netbook computer and a Windows 8 tablet display calibrated to produce equal color contrasts. Both displays showed 100% specificity for confirming CVN and 100% sensitivity for detecting CVD. In CVNs there was no difference between scores on netbook vs. tablet displays. G cone CVDs showed slightly lower G cone CCT scores on the tablet. CVD can be diagnosed with a tablet display. Ease-of-use, portability, and complete computer capabilities make tablets ideal for multiple settings, including aviation, space, military deployments, accidents and rescue missions, and sports vision. Chacon A, Rabin J, Yu D, Johnston S, Bradshaw T. Quantification of color vision using a tablet display.

  1. CIS3/398: Implementation of a Web-Based Electronic Patient Record for Transplant Recipients

    PubMed Central

    Fritsche, L; Lindemann, G; Schroeter, K; Schlaefer, A; Neumayer, H-H

    1999-01-01

    Introduction While the "Electronic patient record" (EPR) is a frequently quoted term in many areas of healthcare, only few working EPR-systems are available so far. To justify their use, EPRs must be able to store and display all kinds of medical information in a reliable, secure, time-saving, user-friendly way at an affordable price. Fields with patients who are attended to by a large number of medical specialists over a prolonged period of time are best suited to demonstrate the potential benefits of an EPR. The aim of our project was to investigate the feasibility of an EPR based solely on "of-the-shelf"-software and Internet-technology in the field of organ transplantation. Methods The EPR-system consists of three main elements: Data-storage facilities, a Web-server and a user-interface. Data are stored either in a relational database (Sybase Adaptive 11.5, Sybase Inc., CA) or in case of pictures (JPEG) and files in application formats (e. g. Word-Documents) on a Windows NT 4.0 Server (Microsoft Corp., WA). The entire communication of all data is handled by a Web-server (IIS 4.0, Microsoft) with an Active Server Pages extension. The database is accessed by ActiveX Data Objects via the ODBC-interface. The only software required on the user's computer is the Internet Explorer 4.01 (Microsoft), during the first use of the EPR, the ActiveX HTML Layout Control is automatically added. The user can access the EPR via Local or Wide Area Network or by dial-up connection. If the EPR is accessed from outside the firewall, all communication is encrypted (SSL 3.0, Netscape Comm. Corp., CA).The speed of the EPR-system was tested with 50 repeated measurements of the duration of two key-functions: 1) Display of all lab results for a given day and patient and 2) automatic composition of a letter containing diagnoses, medication, notes and lab results. For the test a 233 MHz Pentium II Processor with 10 Mbit/s Ethernet connection (ping-time below 10 ms) over 2 hubs to the server (400 MHz Pentium II, 256 MB RAM) was used. Results So far the EPR-system has been running for eight consecutive months and contains complete records of 673 transplant recipients with an average follow-up of 9.9 (SD :4.9) years and a total of 1.1 million lab values. Instruction to enable new users to perform basic operations took less than two hours in all cases. The average duration of laboratory access was 0.9 (SD:0.5) seconds, the automatic composition of a letter took 6.1 (SD:2.4) seconds. Apart from the database and Windows NT, all other components are available for free. The development of the EPR-system required less than two person-years. Conclusion Implementation of an Electronic patient record that meets the requirements of comprehensiveness, reliability, security, speed, user-friendliness and affordability using a combination of "of-the-shelf" software-products can be feasible, if the current state-of-the-art internet technology is applied.

  2. A new version of Visual tool for estimating the fractal dimension of images

    NASA Astrophysics Data System (ADS)

    Grossu, I. V.; Felea, D.; Besliu, C.; Jipa, Al.; Bordeianu, C. C.; Stan, E.; Esanu, T.

    2010-04-01

    This work presents a new version of a Visual Basic 6.0 application for estimating the fractal dimension of images (Grossu et al., 2009 [1]). The earlier version was limited to bi-dimensional sets of points, stored in bitmap files. The application was extended for working also with comma separated values files and three-dimensional images. New version program summaryProgram title: Fractal Analysis v02 Catalogue identifier: AEEG_v2_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEEG_v2_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 9999 No. of bytes in distributed program, including test data, etc.: 4 366 783 Distribution format: tar.gz Programming language: MS Visual Basic 6.0 Computer: PC Operating system: MS Windows 98 or later RAM: 30 M Classification: 14 Catalogue identifier of previous version: AEEG_v1_0 Journal reference of previous version: Comput. Phys. Comm. 180 (2009) 1999 Does the new version supersede the previous version?: Yes Nature of problem: Estimating the fractal dimension of 2D and 3D images. Solution method: Optimized implementation of the box-counting algorithm. Reasons for new version:The previous version was limited to bitmap image files. The new application was extended in order to work with objects stored in comma separated values (csv) files. The main advantages are: Easier integration with other applications (csv is a widely used, simple text file format); Less resources consumed and improved performance (only the information of interest, the "black points", are stored); Higher resolution (the points coordinates are loaded into Visual Basic double variables [2]); Possibility of storing three-dimensional objects (e.g. the 3D Sierpinski gasket). In this version the optimized box-counting algorithm [1] was extended to the three-dimensional case. Summary of revisions:The application interface was changed from SDI (single document interface) to MDI (multi-document interface). One form was added in order to provide a graphical user interface for the new functionalities (fractal analysis of 2D and 3D images stored in csv files). Additional comments: User friendly graphical interface; Easy deployment mechanism. Running time: In the first approximation, the algorithm is linear. References:[1] I.V. Grossu, C. Besliu, M.V. Rusu, Al. Jipa, C.C. Bordeianu, D. Felea, Comput. Phys. Comm. 180 (2009) 1999-2001.[2] F. Balena, Programming Microsoft Visual Basic 6.0, Microsoft Press, US, 1999.

  3. 7 CFR 2201.17 - Submission of applications.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... completed application. (b) Application deadline. One or more application windows will be announced. The duration of each application window for submission of applications will be approximately 120 days. Notice of an application window will be published in the Federal Register. ...

  4. Research of GIS-services applicability for solution of spatial analysis tasks.

    NASA Astrophysics Data System (ADS)

    Terekhin, D. A.; Botygin, I. A.; Sherstneva, A. I.; Sherstnev, V. S.

    2017-01-01

    Experiments for working out the areas of applying various gis-services in the tasks of spatial analysis are discussed in this paper. Google Maps, Yandex Maps, Microsoft SQL Server are used as services of spatial analysis. All services have shown a comparable speed of analyzing the spatial data when carrying out elemental spatial requests (building up the buffer zone of a point object) as well as the preferences of Microsoft SQL Server in operating with more complicated spatial requests. When building up elemental spatial requests, internet-services show higher efficiency due to cliental data handling with JavaScript-subprograms. A weak point of public internet-services is an impossibility to handle data on a server side and a barren variety of spatial analysis functions. Microsoft SQL Server offers a large variety of functions needed for spatial analysis on the server side. The authors conclude that when solving practical problems, the capabilities of internet-services used in building up routes and completing other functions with spatial analysis with Microsoft SQL Server should be involved.

  5. A Microsoft Kinect-Based Point-of-Care Gait Assessment Framework for Multiple Sclerosis Patients.

    PubMed

    Gholami, Farnood; Trojan, Daria A; Kovecses, Jozsef; Haddad, Wassim M; Gholami, Behnood

    2017-09-01

    Gait impairment is a prevalent and important difficulty for patients with multiple sclerosis (MS), a common neurological disorder. An easy to use tool to objectively evaluate gait in MS patients in a clinical setting can assist clinicians to perform an objective assessment. The overall objective of this study is to develop a framework to quantify gait abnormalities in MS patients using the Microsoft Kinect for the Windows sensor; an inexpensive, easy to use, portable camera. Specifically, we aim to evaluate its feasibility for utilization in a clinical setting, assess its reliability, evaluate the validity of gait indices obtained, and evaluate a novel set of gait indices based on the concept of dynamic time warping. In this study, ten ambulatory MS patients, and ten age and sex-matched normal controls were studied at one session in a clinical setting with gait assessment using a Kinect camera. The expanded disability status scale (EDSS) clinical ambulation score was calculated for the MS subjects, and patients completed the Multiple Sclerosis walking scale (MSWS). Based on this study, we established the potential feasibility of using a Microsoft Kinect camera in a clinical setting. Seven out of the eight gait indices obtained using the proposed method were reliable with intraclass correlation coefficients ranging from 0.61 to 0.99. All eight MS gait indices were significantly different from those of the controls (p-values less than 0.05). Finally, seven out of the eight MS gait indices were correlated with the objective and subjective gait measures (Pearson's correlation coefficients greater than 0.40). This study shows that the Kinect camera is an easy to use tool to assess gait in MS patients in a clinical setting.

  6. Rapid application design of an electronic clinical skills portfolio for undergraduate medical students.

    PubMed

    Dornan, Tim; Lee, Catherine; Stopford, Adam; Hosie, Liam; Maredia, Neil; Rector, Alan

    2005-04-01

    The aim was to find how to use information and communication technology to present the clinical skills content of an undergraduate medical curriculum. Rapid application design was used to develop the product, and technical action research was used to evaluate the development process. A clinician-educator, two medical students, two computing science masters students, two other project workers, and a hospital education informatics lead, formed a design team. A sample of stakeholders took part in requirements planning workshops and continued to advise the team throughout the project. A university hospital had many features that favoured fast, inexpensive, and successful system development: a clearly defined and readily accessible user group; location of the development process close to end-users; fast, informal communication; leadership by highly motivated and senior end-users; devolved authority and lack of any rigidly imposed management structure; cooperation of clinicians because the project drew on their clinical expertise to achieve scholastic goals; a culture of learning and involvement of highly motivated students. A detailed specification was developed through storyboarding, use case diagramming, and evolutionary prototyping. A very usable working product was developed within weeks. "SkillsBase" is a database web application using Microsoft Active Server Pages, served from a Microsoft Windows 2000 Server operating system running Internet Information Server 5.0. Graphing functionality is provided by the KavaChart applet. It presents the skills curriculum, provides a password-protected portfolio function, and offers training materials. The curriculum can be presented in several different ways to help students reflect on their objectives and progress towards achieving them. The reflective portfolio function is entirely private to each student user and allows them to document their progress in attaining skills, as judged by self, peer and tutor assessment, and examinations. Training materials include web links and materials developed locally using pedagogic principles developed by the SkillsBase team. Although the usability of SkillsBase has been proven, uptake of software that has arisen 'bottom-up' from within the curriculum has proved slow. We plan to incorporate the SkillsBase services into a more comprehensive virtual managed learning environment, anticipating that presenting the functionality in an environment that is routinely used by students and teachers will increase uptake and use.

  7. Spotlight-8 Image Analysis Software

    NASA Technical Reports Server (NTRS)

    Klimek, Robert; Wright, Ted

    2006-01-01

    Spotlight is a cross-platform GUI-based software package designed to perform image analysis on sequences of images generated by combustion and fluid physics experiments run in a microgravity environment. Spotlight can perform analysis on a single image in an interactive mode or perform analysis on a sequence of images in an automated fashion. Image processing operations can be employed to enhance the image before various statistics and measurement operations are performed. An arbitrarily large number of objects can be analyzed simultaneously with independent areas of interest. Spotlight saves results in a text file that can be imported into other programs for graphing or further analysis. Spotlight can be run on Microsoft Windows, Linux, and Apple OS X platforms.

  8. Tablet—next generation sequence assembly visualization

    PubMed Central

    Milne, Iain; Bayer, Micha; Cardle, Linda; Shaw, Paul; Stephen, Gordon; Wright, Frank; Marshall, David

    2010-01-01

    Summary: Tablet is a lightweight, high-performance graphical viewer for next-generation sequence assemblies and alignments. Supporting a range of input assembly formats, Tablet provides high-quality visualizations showing data in packed or stacked views, allowing instant access and navigation to any region of interest, and whole contig overviews and data summaries. Tablet is both multi-core aware and memory efficient, allowing it to handle assemblies containing millions of reads, even on a 32-bit desktop machine. Availability: Tablet is freely available for Microsoft Windows, Apple Mac OS X, Linux and Solaris. Fully bundled installers can be downloaded from http://bioinf.scri.ac.uk/tablet in 32- and 64-bit versions. Contact: tablet@scri.ac.uk PMID:19965881

  9. Software Review: A program for testing capture-recapture data for closure

    USGS Publications Warehouse

    Stanley, Thomas R.; Richards, Jon D.

    2005-01-01

    Capture-recapture methods are widely used to estimate population parameters of free-ranging animals. Closed-population capture-recapture models, which assume there are no additions to or losses from the population over the period of study (i.e., the closure assumption), are preferred for population estimation over the open-population models, which do not assume closure, because heterogeneity in detection probabilities can be accounted for and this improves estimates. In this paper we introduce CloseTest, a new Microsoft® Windows-based program that computes the Otis et al. (1978) and Stanley and Burnham (1999) closure tests for capture-recapture data sets. Information on CloseTest features and where to obtain the program are provided.

  10. Sbexpert users guide (version 1.0): A knowledge-based decision-support system for spruce beetle management. Forest Service general technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reynolds, K.M.; Holsten, E.H.; Werner, R.A.

    1995-03-01

    SBexpert version 1.0 is a knowledge-based decision-support system for management of spruce beetle developed for use in Microsoft Windows. The users guide provides detailed instructions on the use of all SBexpert features. SBexpert has four main subprograms; introduction, analysis, textbook, and literature. The introduction is the first of the five subtopics in the SBexpert help system. The analysis topic is an advisory system for spruce beetle management that provides recommendation for reducing spruce beetle hazard and risk to spruce stands and is the main analytical topic in SBexpert. The textbook and literature topics provide complementary decision support for analysis.

  11. Cloud Computing Based E-Learning System

    ERIC Educational Resources Information Center

    Al-Zoube, Mohammed; El-Seoud, Samir Abou; Wyne, Mudasser F.

    2010-01-01

    Cloud computing technologies although in their early stages, have managed to change the way applications are going to be developed and accessed. These technologies are aimed at running applications as services over the internet on a flexible infrastructure. Microsoft office applications, such as word processing, excel spreadsheet, access database…

  12. Kinect as a Tool for Gait Analysis: Validation of a Real-Time Joint Extraction Algorithm Working in Side View

    PubMed Central

    Cippitelli, Enea; Gasparrini, Samuele; Spinsante, Susanna; Gambi, Ennio

    2015-01-01

    The Microsoft Kinect sensor has gained attention as a tool for gait analysis for several years. Despite the many advantages the sensor provides, however, the lack of a native capability to extract joints from the side view of a human body still limits the adoption of the device to a number of relevant applications. This paper presents an algorithm to locate and estimate the trajectories of up to six joints extracted from the side depth view of a human body captured by the Kinect device. The algorithm is then applied to extract data that can be exploited to provide an objective score for the “Get Up and Go Test”, which is typically adopted for gait analysis in rehabilitation fields. Starting from the depth-data stream provided by the Microsoft Kinect sensor, the proposed algorithm relies on anthropometric models only, to locate and identify the positions of the joints. Differently from machine learning approaches, this solution avoids complex computations, which usually require significant resources. The reliability of the information about the joint position output by the algorithm is evaluated by comparison to a marker-based system. Tests show that the trajectories extracted by the proposed algorithm adhere to the reference curves better than the ones obtained from the skeleton generated by the native applications provided within the Microsoft Kinect (Microsoft Corporation, Redmond, WA, USA, 2013) and OpenNI (OpenNI organization, Tel Aviv, Israel, 2013) Software Development Kits. PMID:25594588

  13. A survey of tools for the analysis of quantitative PCR (qPCR) data.

    PubMed

    Pabinger, Stephan; Rödiger, Stefan; Kriegner, Albert; Vierlinger, Klemens; Weinhäusel, Andreas

    2014-09-01

    Real-time quantitative polymerase-chain-reaction (qPCR) is a standard technique in most laboratories used for various applications in basic research. Analysis of qPCR data is a crucial part of the entire experiment, which has led to the development of a plethora of methods. The released tools either cover specific parts of the workflow or provide complete analysis solutions. Here, we surveyed 27 open-access software packages and tools for the analysis of qPCR data. The survey includes 8 Microsoft Windows, 5 web-based, 9 R-based and 5 tools from other platforms. Reviewed packages and tools support the analysis of different qPCR applications, such as RNA quantification, DNA methylation, genotyping, identification of copy number variations, and digital PCR. We report an overview of the functionality, features and specific requirements of the individual software tools, such as data exchange formats, availability of a graphical user interface, included procedures for graphical data presentation, and offered statistical methods. In addition, we provide an overview about quantification strategies, and report various applications of qPCR. Our comprehensive survey showed that most tools use their own file format and only a fraction of the currently existing tools support the standardized data exchange format RDML. To allow a more streamlined and comparable analysis of qPCR data, more vendors and tools need to adapt the standardized format to encourage the exchange of data between instrument software, analysis tools, and researchers.

  14. 78 FR 61350 - Tribal Mobility Fund Phase I Auction (Auction 902); Short-Form Application Filing Window...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-03

    ... Fund Phase I Auction (Auction 902); Short-Form Application Filing Window Rescheduled To Open on... rescheduling of the filing window for short-form applications and release an updated list of eligible areas for... Application Filing Window Rescheduled To Open on September 30, 2013 1. The Bureaus announce that the filing...

  15. Simple proteomics data analysis in the object-oriented PowerShell.

    PubMed

    Mohammed, Yassene; Palmblad, Magnus

    2013-01-01

    Scripting languages such as Perl and Python are appreciated for solving simple, everyday tasks in bioinformatics. A more recent, object-oriented command shell and scripting language, Windows PowerShell, has many attractive features: an object-oriented interactive command line, fluent navigation and manipulation of XML files, ability to consume Web services from the command line, consistent syntax and grammar, rich regular expressions, and advanced output formatting. The key difference between classical command shells and scripting languages, such as bash, and object-oriented ones, such as PowerShell, is that in the latter the result of a command is a structured object with inherited properties and methods rather than a simple stream of characters. Conveniently, PowerShell is included in all new releases of Microsoft Windows and therefore already installed on most computers in classrooms and teaching labs. In this chapter we demonstrate how PowerShell in particular allows easy interaction with mass spectrometry data in XML formats, connection to Web services for tools such as BLAST, and presentation of results as formatted text or graphics. These features make PowerShell much more than "yet another scripting language."

  16. Neuropsychological Testing of Astronauts

    NASA Technical Reports Server (NTRS)

    Flynn, Christopher; Vander Ark, Steve; Eksuzian, Daniel; Sipes, Walter; Kane, Robert; Vanderploeg, Rodney; Retzlaff, Paul; Elsmore, Tim; Moore, Jeffrey

    2004-01-01

    The Spaceflight Cognitive Assessment Tool for Windows (WinSCAT) is a computer program that administers a battery of five timed neuro-cognitive tests. WinSCAT was developed to give astronauts an objective and automated means of assessing their cognitive functioning during space flight, as compared with their own baseline performances measured during similar prior testing on the ground. WinSCAT is also intended for use by flight surgeons to assess cognitive impairment after exposure of astronauts to such cognitive assaults as head trauma, decompression sickness, and exposure to toxic gas. The tests were selected from among a group of tests, denoted the Automated Neuropsychological Assessment Metrics, that were created by the United States Navy and Army for use in evaluating the cognitive impairment of military personnel who have been subjected to medication or are suspected to have sustained brain injuries. These tests have been validated in a variety of clinical settings and are now in the public domain. The tests are presented in a Microsoft Windows shell that facilitates administration and enables immediate reporting of test scores in numerical and graphical forms.

  17. Spectral Analysis Tool 6.2 for Windows

    NASA Technical Reports Server (NTRS)

    Morgan, Feiming; Sue, Miles; Peng, Ted; Tan, Harry; Liang, Robert; Kinman, Peter

    2006-01-01

    Spectral Analysis Tool 6.2 is the latest version of a computer program that assists in analysis of interference between radio signals of the types most commonly used in Earth/spacecraft radio communications. [An earlier version was reported in Software for Analyzing Earth/Spacecraft Radio Interference (NPO-20422), NASA Tech Briefs, Vol. 25, No. 4 (April 2001), page 52.] SAT 6.2 calculates signal spectra, bandwidths, and interference effects for several families of modulation schemes. Several types of filters can be modeled, and the program calculates and displays signal spectra after filtering by any of the modeled filters. The program accommodates two simultaneous signals: a desired signal and an interferer. The interference-to-signal power ratio can be calculated for the filtered desired and interfering signals. Bandwidth-occupancy and link-budget calculators are included for the user s convenience. SAT 6.2 has a new software structure and provides a new user interface that is both intuitive and convenient. SAT 6.2 incorporates multi-tasking, multi-threaded execution, virtual memory management, and a dynamic link library. SAT 6.2 is designed for use on 32- bit computers employing Microsoft Windows operating systems.

  18. Application for internal dosimetry using biokinetic distribution of photons based on nuclear medicine images.

    PubMed

    Leal Neto, Viriato; Vieira, José Wilson; Lima, Fernando Roberto de Andrade

    2014-01-01

    This article presents a way to obtain estimates of dose in patients submitted to radiotherapy with basis on the analysis of regions of interest on nuclear medicine images. A software called DoRadIo (Dosimetria das Radiações Ionizantes [Ionizing Radiation Dosimetry]) was developed to receive information about source organs and target organs, generating graphical and numerical results. The nuclear medicine images utilized in the present study were obtained from catalogs provided by medical physicists. The simulations were performed with computational exposure models consisting of voxel phantoms coupled with the Monte Carlo EGSnrc code. The software was developed with the Microsoft Visual Studio 2010 Service Pack and the project template Windows Presentation Foundation for C# programming language. With the mentioned tools, the authors obtained the file for optimization of Monte Carlo simulations using the EGSnrc; organization and compaction of dosimetry results with all radioactive sources; selection of regions of interest; evaluation of grayscale intensity in regions of interest; the file of weighted sources; and, finally, all the charts and numerical results. The user interface may be adapted for use in clinical nuclear medicine as a computer-aided tool to estimate the administered activity.

  19. System-of-Systems Technology-Portfolio-Analysis Tool

    NASA Technical Reports Server (NTRS)

    O'Neil, Daniel; Mankins, John; Feingold, Harvey; Johnson, Wayne

    2012-01-01

    Advanced Technology Life-cycle Analysis System (ATLAS) is a system-of-systems technology-portfolio-analysis software tool. ATLAS affords capabilities to (1) compare estimates of the mass and cost of an engineering system based on competing technological concepts; (2) estimate life-cycle costs of an outer-space-exploration architecture for a specified technology portfolio; (3) collect data on state-of-the-art and forecasted technology performance, and on operations and programs; and (4) calculate an index of the relative programmatic value of a technology portfolio. ATLAS facilitates analysis by providing a library of analytical spreadsheet models for a variety of systems. A single analyst can assemble a representation of a system of systems from the models and build a technology portfolio. Each system model estimates mass, and life-cycle costs are estimated by a common set of cost models. Other components of ATLAS include graphical-user-interface (GUI) software, algorithms for calculating the aforementioned index, a technology database, a report generator, and a form generator for creating the GUI for the system models. At the time of this reporting, ATLAS is a prototype, embodied in Microsoft Excel and several thousand lines of Visual Basic for Applications that run on both Windows and Macintosh computers.

  20. Fish Karyome: A karyological information network database of Indian Fishes.

    PubMed

    Nagpure, Naresh Sahebrao; Pathak, Ajey Kumar; Pati, Rameshwar; Singh, Shri Prakash; Singh, Mahender; Sarkar, Uttam Kumar; Kushwaha, Basdeo; Kumar, Ravindra

    2012-01-01

    'Fish Karyome', a database on karyological information of Indian fishes have been developed that serves as central source for karyotype data about Indian fishes compiled from the published literature. Fish Karyome has been intended to serve as a liaison tool for the researchers and contains karyological information about 171 out of 2438 finfish species reported in India and is publically available via World Wide Web. The database provides information on chromosome number, morphology, sex chromosomes, karyotype formula and cytogenetic markers etc. Additionally, it also provides the phenotypic information that includes species name, its classification, and locality of sample collection, common name, local name, sex, geographical distribution, and IUCN Red list status. Besides, fish and karyotype images, references for 171 finfish species have been included in the database. Fish Karyome has been developed using SQL Server 2008, a relational database management system, Microsoft's ASP.NET-2008 and Macromedia's FLASH Technology under Windows 7 operating environment. The system also enables users to input new information and images into the database, search and view the information and images of interest using various search options. Fish Karyome has wide range of applications in species characterization and identification, sex determination, chromosomal mapping, karyo-evolution and systematics of fishes.

  1. Preliminary In-Flight Loads Analysis of In-Line Launch Vehicles using the VLOADS 1.4 Program

    NASA Technical Reports Server (NTRS)

    Graham, J. B.; Luz, P. L.

    1998-01-01

    To calculate structural loads of in-line launch vehicles for preliminary design, a very useful computer program is VLOADS 1.4. This software may also be used to calculate structural loads for upper stages and planetary transfer vehicles. Launch vehicle inputs such as aerodynamic coefficients, mass properties, propellants, engine thrusts, and performance data are compiled and analyzed by VLOADS to produce distributed shear loads, bending moments, axial forces, and vehicle line loads as a function of X-station along the vehicle's length. Interface loads, if any, and translational accelerations are also computed. The major strength of the software is that it enables quick turnaround analysis of structural loads for launch vehicles during the preliminary design stage of its development. This represents a significant improvement over the alternative-the time-consuming, and expensive chore of developing finite element models. VLOADS was developed as a Visual BASIC macro in a Microsoft Excel 5.0 work book on a Macintosh. VLOADS has also been implemented on a PC computer using Microsoft Excel 7.0a for Windows 95. VLOADS was developed in 1996, and the current version was released to COSMIC, NASA's Software Technology Transfer Center, in 1997. The program is a copyrighted work with all copyright vested in NASA.

  2. Performance analysis of the Microsoft Kinect sensor for 2D Simultaneous Localization and Mapping (SLAM) techniques.

    PubMed

    Kamarudin, Kamarulzaman; Mamduh, Syed Muhammad; Shakaff, Ali Yeon Md; Zakaria, Ammar

    2014-12-05

    This paper presents a performance analysis of two open-source, laser scanner-based Simultaneous Localization and Mapping (SLAM) techniques (i.e., Gmapping and Hector SLAM) using a Microsoft Kinect to replace the laser sensor. Furthermore, the paper proposes a new system integration approach whereby a Linux virtual machine is used to run the open source SLAM algorithms. The experiments were conducted in two different environments; a small room with no features and a typical office corridor with desks and chairs. Using the data logged from real-time experiments, each SLAM technique was simulated and tested with different parameter settings. The results show that the system is able to achieve real time SLAM operation. The system implementation offers a simple and reliable way to compare the performance of Windows-based SLAM algorithm with the algorithms typically implemented in a Robot Operating System (ROS). The results also indicate that certain modifications to the default laser scanner-based parameters are able to improve the map accuracy. However, the limited field of view and range of Kinect's depth sensor often causes the map to be inaccurate, especially in featureless areas, therefore the Kinect sensor is not a direct replacement for a laser scanner, but rather offers a feasible alternative for 2D SLAM tasks.

  3. Performance Analysis of the Microsoft Kinect Sensor for 2D Simultaneous Localization and Mapping (SLAM) Techniques

    PubMed Central

    Kamarudin, Kamarulzaman; Mamduh, Syed Muhammad; Shakaff, Ali Yeon Md; Zakaria, Ammar

    2014-01-01

    This paper presents a performance analysis of two open-source, laser scanner-based Simultaneous Localization and Mapping (SLAM) techniques (i.e., Gmapping and Hector SLAM) using a Microsoft Kinect to replace the laser sensor. Furthermore, the paper proposes a new system integration approach whereby a Linux virtual machine is used to run the open source SLAM algorithms. The experiments were conducted in two different environments; a small room with no features and a typical office corridor with desks and chairs. Using the data logged from real-time experiments, each SLAM technique was simulated and tested with different parameter settings. The results show that the system is able to achieve real time SLAM operation. The system implementation offers a simple and reliable way to compare the performance of Windows-based SLAM algorithm with the algorithms typically implemented in a Robot Operating System (ROS). The results also indicate that certain modifications to the default laser scanner-based parameters are able to improve the map accuracy. However, the limited field of view and range of Kinect's depth sensor often causes the map to be inaccurate, especially in featureless areas, therefore the Kinect sensor is not a direct replacement for a laser scanner, but rather offers a feasible alternative for 2D SLAM tasks. PMID:25490595

  4. Security Implications of OPC, OLE, DCOM, and RPC in Control Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2006-01-01

    OPC is a collection of software programming standards and interfaces used in the process control industry. It is intended to provide open connectivity and vendor equipment interoperability. The use of OPC technology simplifies the development of control systems that integrate components from multiple vendors and support multiple control protocols. OPC-compliant products are available from most control system vendors, and are widely used in the process control industry. OPC was originally known as OLE for Process Control; the first standards for OPC were based on underlying services in the Microsoft Windows computing environment. These underlying services (OLE [Object Linking and Embedding],more » DCOM [Distributed Component Object Model], and RPC [Remote Procedure Call]) have been the source of many severe security vulnerabilities. It is not feasible to automatically apply vendor patches and service packs to mitigate these vulnerabilities in a control systems environment. Control systems using the original OPC data access technology can thus inherit the vulnerabilities associated with these services. Current OPC standardization efforts are moving away from the original focus on Microsoft protocols, with a distinct trend toward web-based protocols that are independent of any particular operating system. However, the installed base of OPC equipment consists mainly of legacy implementations of the OLE for Process Control protocols.« less

  5. Informatics in radiology (infoRAD): free DICOM image viewing and processing software for the Macintosh computer: what's available and what it can do for you.

    PubMed

    Escott, Edward J; Rubinstein, David

    2004-01-01

    It is often necessary for radiologists to use digital images in presentations and conferences. Most imaging modalities produce images in the Digital Imaging and Communications in Medicine (DICOM) format. The image files tend to be large and thus cannot be directly imported into most presentation software, such as Microsoft PowerPoint; the large files also consume storage space. There are many free programs that allow viewing and processing of these files on a personal computer, including conversion to more common file formats such as the Joint Photographic Experts Group (JPEG) format. Free DICOM image viewing and processing software for computers running on the Microsoft Windows operating system has already been evaluated. However, many people use the Macintosh (Apple Computer) platform, and a number of programs are available for these users. The World Wide Web was searched for free DICOM image viewing or processing software that was designed for the Macintosh platform or is written in Java and is therefore platform independent. The features of these programs and their usability were evaluated. There are many free programs for the Macintosh platform that enable viewing and processing of DICOM images. (c) RSNA, 2004.

  6. xdamp Version 6 : an IDL-based data and image manipulation program.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ballard, William Parker

    2012-04-01

    The original DAMP (DAta Manipulation Program) was written by Mark Hedemann of Sandia National Laboratories and used the CA-DISSPLA{trademark} (available from Computer Associates International, Inc., Garden City, NY) graphics package as its engine. It was used to plot, modify, and otherwise manipulate the one-dimensional data waveforms (data vs. time) from a wide variety of accelerators. With the waning of CA-DISSPLA and the increasing popularity of Unix(reg sign)-based workstations, a replacement was needed. This package uses the IDL(reg sign) software, available from Research Systems Incorporated, a Xerox company, in Boulder, Colorado, as the engine, and creates a set of widgets tomore » manipulate the data in a manner similar to the original DAMP and earlier versions of xdamp. IDL is currently supported on a wide variety of Unix platforms such as IBM(reg sign) workstations, Hewlett Packard workstations, SUN(reg sign) workstations, Microsoft(reg sign) Windows{trademark} computers, Macintosh(reg sign) computers and Digital Equipment Corporation VMS(reg sign) and Alpha(reg sign) systems. Thus, xdamp is portable across many platforms. We have verified operation, albeit with some minor IDL bugs, on personal computers using Windows 7 and Windows Vista; Unix platforms; and Macintosh computers. Version 6 is an update that uses the IDL Virtual Machine to resolve the need for licensing IDL.« less

  7. Visualization of molecular structures using HoloLens-based augmented reality

    PubMed Central

    Hoffman, MA; Provance, JB

    2017-01-01

    Biological molecules and biologically active small molecules are complex three dimensional structures. Current flat screen monitors are limited in their ability to convey the full three dimensional characteristics of these molecules. Augmented reality devices, including the Microsoft HoloLens, offer an immersive platform to change how we interact with molecular visualizations. We describe a process to incorporate the three dimensional structures of small molecules and complex proteins into the Microsoft HoloLens using aspirin and the human leukocyte antigen (HLA) as examples. Small molecular structures can be introduced into the HoloStudio application, which provides native support for rotating, resizing and performing other interactions with these molecules. Larger molecules can be imported through the Unity gaming development platform and then Microsoft Visual Developer. The processes described here can be modified to import a wide variety of molecular structures into augmented reality systems and improve our comprehension of complex structural features. PMID:28815109

  8. imDEV: a graphical user interface to R multivariate analysis tools in Microsoft Excel.

    PubMed

    Grapov, Dmitry; Newman, John W

    2012-09-01

    Interactive modules for Data Exploration and Visualization (imDEV) is a Microsoft Excel spreadsheet embedded application providing an integrated environment for the analysis of omics data through a user-friendly interface. Individual modules enables interactive and dynamic analyses of large data by interfacing R's multivariate statistics and highly customizable visualizations with the spreadsheet environment, aiding robust inferences and generating information-rich data visualizations. This tool provides access to multiple comparisons with false discovery correction, hierarchical clustering, principal and independent component analyses, partial least squares regression and discriminant analysis, through an intuitive interface for creating high-quality two- and a three-dimensional visualizations including scatter plot matrices, distribution plots, dendrograms, heat maps, biplots, trellis biplots and correlation networks. Freely available for download at http://sourceforge.net/projects/imdev/. Implemented in R and VBA and supported by Microsoft Excel (2003, 2007 and 2010).

  9. GLobal Integrated Design Environment (GLIDE): A Concurrent Engineering Application

    NASA Technical Reports Server (NTRS)

    McGuire, Melissa L.; Kunkel, Matthew R.; Smith, David A.

    2010-01-01

    The GLobal Integrated Design Environment (GLIDE) is a client-server software application purpose-built to mitigate issues associated with real time data sharing in concurrent engineering environments and to facilitate discipline-to-discipline interaction between multiple engineers and researchers. GLIDE is implemented in multiple programming languages utilizing standardized web protocols to enable secure parameter data sharing between engineers and researchers across the Internet in closed and/or widely distributed working environments. A well defined, HyperText Transfer Protocol (HTTP) based Application Programming Interface (API) to the GLIDE client/server environment enables users to interact with GLIDE, and each other, within common and familiar tools. One such common tool, Microsoft Excel (Microsoft Corporation), paired with its add-in API for GLIDE, is discussed in this paper. The top-level examples given demonstrate how this interface improves the efficiency of the design process of a concurrent engineering study while reducing potential errors associated with manually sharing information between study participants.

  10. Calibration of Kinect for Xbox One and Comparison between the Two Generations of Microsoft Sensors

    PubMed Central

    Pagliari, Diana; Pinto, Livio

    2015-01-01

    In recent years, the videogame industry has been characterized by a great boost in gesture recognition and motion tracking, following the increasing request of creating immersive game experiences. The Microsoft Kinect sensor allows acquiring RGB, IR and depth images with a high frame rate. Because of the complementary nature of the information provided, it has proved an attractive resource for researchers with very different backgrounds. In summer 2014, Microsoft launched a new generation of Kinect on the market, based on time-of-flight technology. This paper proposes a calibration of Kinect for Xbox One imaging sensors, focusing on the depth camera. The mathematical model that describes the error committed by the sensor as a function of the distance between the sensor itself and the object has been estimated. All the analyses presented here have been conducted for both generations of Kinect, in order to quantify the improvements that characterize every single imaging sensor. Experimental results show that the quality of the delivered model improved applying the proposed calibration procedure, which is applicable to both point clouds and the mesh model created with the Microsoft Fusion Libraries. PMID:26528979

  11. Calibration of Kinect for Xbox One and Comparison between the Two Generations of Microsoft Sensors.

    PubMed

    Pagliari, Diana; Pinto, Livio

    2015-10-30

    In recent years, the videogame industry has been characterized by a great boost in gesture recognition and motion tracking, following the increasing request of creating immersive game experiences. The Microsoft Kinect sensor allows acquiring RGB, IR and depth images with a high frame rate. Because of the complementary nature of the information provided, it has proved an attractive resource for researchers with very different backgrounds. In summer 2014, Microsoft launched a new generation of Kinect on the market, based on time-of-flight technology. This paper proposes a calibration of Kinect for Xbox One imaging sensors, focusing on the depth camera. The mathematical model that describes the error committed by the sensor as a function of the distance between the sensor itself and the object has been estimated. All the analyses presented here have been conducted for both generations of Kinect, in order to quantify the improvements that characterize every single imaging sensor. Experimental results show that the quality of the delivered model improved applying the proposed calibration procedure, which is applicable to both point clouds and the mesh model created with the Microsoft Fusion Libraries.

  12. CProb: a computational tool for conducting conditional probability analysis.

    PubMed

    Hollister, Jeffrey W; Walker, Henry A; Paul, John F

    2008-01-01

    Conditional probability is the probability of observing one event given that another event has occurred. In an environmental context, conditional probability helps to assess the association between an environmental contaminant (i.e., the stressor) and the ecological condition of a resource (i.e., the response). These analyses, when combined with controlled experiments and other methodologies, show great promise in evaluating ecological conditions from observational data and in defining water quality and other environmental criteria. Current applications of conditional probability analysis (CPA) are largely done via scripts or cumbersome spreadsheet routines, which may prove daunting to end-users and do not provide access to the underlying scripts. Combining spreadsheets with scripts eases computation through a familiar interface (i.e., Microsoft Excel) and creates a transparent process through full accessibility to the scripts. With this in mind, we developed a software application, CProb, as an Add-in for Microsoft Excel with R, R(D)com Server, and Visual Basic for Applications. CProb calculates and plots scatterplots, empirical cumulative distribution functions, and conditional probability. In this short communication, we describe CPA, our motivation for developing a CPA tool, and our implementation of CPA as a Microsoft Excel Add-in. Further, we illustrate the use of our software with two examples: a water quality example and a landscape example. CProb is freely available for download at http://www.epa.gov/emap/nca/html/regions/cprob.

  13. Physiologically based pharmacokinetic modeling using microsoft excel and visual basic for applications.

    PubMed

    Marino, Dale J

    2005-01-01

    Abstract Physiologically based pharmacokinetic (PBPK) models are mathematical descriptions depicting the relationship between external exposure and internal dose. These models have found great utility for interspecies extrapolation. However, specialized computer software packages, which are not widely distributed, have typically been used for model development and utilization. A few physiological models have been reported using more widely available software packages (e.g., Microsoft Excel), but these tend to include less complex processes and dose metrics. To ascertain the capability of Microsoft Excel and Visual Basis for Applications (VBA) for PBPK modeling, models for styrene, vinyl chloride, and methylene chloride were coded in Advanced Continuous Simulation Language (ACSL), Excel, and VBA, and simulation results were compared. For styrene, differences between ACSL and Excel or VBA compartment concentrations and rates of change were less than +/-7.5E-10 using the same numerical integration technique and time step. Differences using VBA fixed step or ACSL Gear's methods were generally <1.00E-03, although larger differences involving very small values were noted after exposure transitions. For vinyl chloride and methylene chloride, Excel and VBA PBPK model dose metrics differed by no more than -0.013% or -0.23%, respectively, from ACSL results. These differences are likely attributable to different step sizes rather than different numerical integration techniques. These results indicate that Microsoft Excel and VBA can be useful tools for utilizing PBPK models, and given the availability of these software programs, it is hoped that this effort will help facilitate the use and investigation of PBPK modeling.

  14. Electronic Attack Platform Placement Optimization

    DTIC Science & Technology

    2014-09-01

    Processing in VBA ...............................................................33 2. Client-Server Using Two Different Excel Application...6 Figure 3. Screenshot of the VBA IDE contained within all Microsoft Office products...application using MS Excel’s Applicatin.OnTime method. .....................................33 Figure 20. WINSOCK API Functions needed to use TCP via VBA

  15. Excel2Genie: A Microsoft Excel application to improve the flexibility of the Genie-2000 Spectroscopic software.

    PubMed

    Forgács, Attila; Balkay, László; Trón, Lajos; Raics, Péter

    2014-12-01

    Excel2Genie, a simple and user-friendly Microsoft Excel interface, has been developed to the Genie-2000 Spectroscopic Software of Canberra Industries. This Excel application can directly control Canberra Multichannel Analyzer (MCA), process the acquired data and visualize them. Combination of Genie-2000 with Excel2Genie results in remarkably increased flexibility and a possibility to carry out repetitive data acquisitions even with changing parameters and more sophisticated analysis. The developed software package comprises three worksheets: display parameters and results of data acquisition, data analysis and mathematical operations carried out on the measured gamma spectra. At the same time it also allows control of these processes. Excel2Genie is freely available to assist gamma spectrum measurements and data evaluation by the interested Canberra users. With access to the Visual Basic Application (VBA) source code of this application users are enabled to modify the developed interface according to their intentions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. MLM Builder: An Integrated Suite for Development and Maintenance of Arden Syntax Medical Logic Modules

    PubMed Central

    Sailors, R. Matthew

    1997-01-01

    The Arden Syntax specification for sharable computerized medical knowledge bases has not been widely utilized in the medical informatics community because of a lack of tools for developing Arden Syntax knowledge bases (Medical Logic Modules). The MLM Builder is a Microsoft Windows-hosted CASE (Computer Aided Software Engineering) tool designed to aid in the development and maintenance of Arden Syntax Medical Logic Modules (MLMs). The MLM Builder consists of the MLM Writer (an MLM generation tool), OSCAR (an anagram of Object-oriented ARden Syntax Compiler), a test database, and the MLManager (an MLM management information system). Working together, these components form a self-contained, unified development environment for the creation, testing, and maintenance of Arden Syntax Medical Logic Modules.

  17. AMIDE: a free software tool for multimodality medical image analysis.

    PubMed

    Loening, Andreas Markus; Gambhir, Sanjiv Sam

    2003-07-01

    Amide's a Medical Image Data Examiner (AMIDE) has been developed as a user-friendly, open-source software tool for displaying and analyzing multimodality volumetric medical images. Central to the package's abilities to simultaneously display multiple data sets (e.g., PET, CT, MRI) and regions of interest is the on-demand data reslicing implemented within the program. Data sets can be freely shifted, rotated, viewed, and analyzed with the program automatically handling interpolation as needed from the original data. Validation has been performed by comparing the output of AMIDE with that of several existing software packages. AMIDE runs on UNIX, Macintosh OS X, and Microsoft Windows platforms, and it is freely available with source code under the terms of the GNU General Public License.

  18. 75 FR 50986 - Notice of Contract Proposal (NOCP) for Payments to Eligible Advanced Biofuel Producers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-18

    ... remaining available Fiscal Year 2009 program funds. This Notice opens an application window for certain... opening a new application window from August 18, 2010 through September 17, 2010 to accept applications... opening a new application window to accept additional applications for the remaining available Fiscal Year...

  19. An Introduction to X Window Application Development

    DTIC Science & Technology

    1992-03-23

    Acquisition and Policy Evaluation program using Cognitive Feed- back ( ESKAPE /CF) from the SunView windowing system to X Window. The new application...the generic X Window System. This thesis converts an Expert System Knowledge Acquisition and Policy Evaluation program using Cognitive Feedback ( ESKAPE ...15 IV. XESKAPE/CF: THE X WINDOW VERSION OF ESKAPE /CF ........................ 16 A. FUNCTIONAL COMPARISON TO

  20. 77 FR 32034 - Policies To Promote Rural Radio Service and To Streamline Allotment and Assignment Procedures

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-31

    ... Qualifications Window (``TQ Window''). During the TQ Window, any Tribe or Tribal entity that could qualify to add... filed Form 301 application to be considered at this stage, then during the TQ Window the original Tribal... acceptable application is filed during the TQ Window, whether by the original Tribal allotment proponent...

  1. 47 CFR 73.870 - Processing of LPFM broadcast station applications.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Notice a window filing period for applications for new LPFM stations and major modifications in the... authorized LPFM stations will be accepted only during the appropriate window. Applications submitted prior to the window opening date identified in the Public Notice will be returned as premature. Applications...

  2. Microsoft Repository Version 2 and the Open Information Model.

    ERIC Educational Resources Information Center

    Bernstein, Philip A.; Bergstraesser, Thomas; Carlson, Jason; Pal, Shankar; Sanders, Paul; Shutt, David

    1999-01-01

    Describes the programming interface and implementation of the repository engine and the Open Information Model for Microsoft Repository, an object-oriented meta-data management facility that ships in Microsoft Visual Studio and Microsoft SQL Server. Discusses Microsoft's component object model, object manipulation, queries, and information…

  3. Investigating Navy Officer Retention Using Data Farming

    DTIC Science & Technology

    2015-09-01

    runs on Microsoft Access . Contractors from SAG Corporation translated the code into Visual Basic for Applications ( VBA ), bringing several benefits...18  b.  Accessions ............................................................. 18  c.  Promotions...Strategic Actions Group SEED Simulation Experiments & Efficient Design URL Unrestricted Line VBA Visual Basic for Applications VV&A Verification

  4. Ajax and Firefox: New Web Applications and Browsers

    ERIC Educational Resources Information Center

    Godwin-Jones, Bob

    2005-01-01

    Alternative browsers are gaining significant market share, and both Apple and Microsoft are releasing OS upgrades which portend some interesting changes in Web development. Of particular interest for language learning professionals may be new developments in the area of Web browser based applications, particularly using an approach dubbed "Ajax."…

  5. FIREMON Database

    Treesearch

    John F. Caratti

    2006-01-01

    The FIREMON database software allows users to enter data, store, analyze, and summarize plot data, photos, and related documents. The FIREMON database software consists of a Java application and a Microsoft® Access database. The Java application provides the user interface with FIREMON data through data entry forms, data summary reports, and other data management tools...

  6. 75 FR 11889 - Request for Comments on Proposed NIH, AHRQ and CDC Process Change for Electronic Submission of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-12

    ... impact of eliminating the correction window from the electronic grant application submission process on... process a temporary error correction window to ensure a smooth and successful transition for applicants. This window provides applicants a period of time beyond the grant application due date to correct any...

  7. Use phase signals to promote lifetime extension for Windows PCs.

    PubMed

    Hickey, Stewart; Fitzpatrick, Colin; O'Connell, Maurice; Johnson, Michael

    2009-04-01

    This paper proposes a signaling methodology for personal computers. Signaling may be viewed as an ecodesign strategy that can positively influence the consumer to consumer (C2C) market process. A number of parameters are identified that can provide the basis for signal implementation. These include operating time, operating temperature, operating voltage, power cycle counts, hard disk drive (HDD) self-monitoring, and reporting technology (SMART) attributes and operating system (OS) event information. All these parameters are currently attainable or derivable via embedded technologies in modern desktop systems. A case study detailing a technical implementation of how the development of signals can be achieved in personal computers that incorporate Microsoft Windows operating systems is presented. Collation of lifetime temperature data from a system processor is demonstrated as a possible means of characterizing a usage profile for a desktop system. In addition, event log data is utilized for devising signals indicative of OS quality. The provision of lifetime usage data in the form of intuitive signals indicative of both hardware and software quality can in conjunction with consumer education facilitate an optimal remarketing strategy for used systems. This implementation requires no additional hardware.

  8. A Comprehensive Software and Database Management System for Glomerular Filtration Rate Estimation by Radionuclide Plasma Sampling and Serum Creatinine Methods.

    PubMed

    Jha, Ashish Kumar

    2015-01-01

    Glomerular filtration rate (GFR) estimation by plasma sampling method is considered as the gold standard. However, this method is not widely used because the complex technique and cumbersome calculations coupled with the lack of availability of user-friendly software. The routinely used Serum Creatinine method (SrCrM) of GFR estimation also requires the use of online calculators which cannot be used without internet access. We have developed user-friendly software "GFR estimation software" which gives the options to estimate GFR by plasma sampling method as well as SrCrM. We have used Microsoft Windows(®) as operating system and Visual Basic 6.0 as the front end and Microsoft Access(®) as database tool to develop this software. We have used Russell's formula for GFR calculation by plasma sampling method. GFR calculations using serum creatinine have been done using MIRD, Cockcroft-Gault method, Schwartz method, and Counahan-Barratt methods. The developed software is performing mathematical calculations correctly and is user-friendly. This software also enables storage and easy retrieval of the raw data, patient's information and calculated GFR for further processing and comparison. This is user-friendly software to calculate the GFR by various plasma sampling method and blood parameter. This software is also a good system for storing the raw and processed data for future analysis.

  9. A comparison of traditional textbook and interactive computer learning of neuromuscular block.

    PubMed

    Ohrn, M A; van Oostrom, J H; van Meurs, W L

    1997-03-01

    We designed an educational software package, RELAX, for teaching first-year anesthesiology residents about the pharmacology and clinical management of neuromuscular blockade. The software uses an interactive, problem-based approach and moves the user through cases in an operating room environment. It can be run on personal computers with Microsoft Windows (Microsoft Corp., Redmond, WA) and combines video, graphics, and text with mouse-driven user input. We utilized test scores 1) to determine whether our software was beneficial to be the educational progress of anesthesiology residents and 2) to compare computer-based learning with textbook learning. Twenty-three residents were divided into two groups matched for age and sex, and a pretest was administered to all 23 residents. There was no significant difference (P > 0.05) in the pretest scores of the two groups. Three weeks later, both groups were subjected to an educational intervention; one with our computer software and the other with selected textbooks. Both groups took a posttest immediately after the intervention. The test scores of the computer group improved significantly more (P < 0.05) than those of the textbook group. Although prior to the study the two groups showed no statistical difference in their familiarity with computers, the computer group reported much higher satisfaction with their learning experience than did the textbook group (P < 0.0001).

  10. "TPSX: Thermal Protection System Expert and Material Property Database"

    NASA Technical Reports Server (NTRS)

    Squire, Thomas H.; Milos, Frank S.; Rasky, Daniel J. (Technical Monitor)

    1997-01-01

    The Thermal Protection Branch at NASA Ames Research Center has developed a computer program for storing, organizing, and accessing information about thermal protection materials. The program, called Thermal Protection Systems Expert and Material Property Database, or TPSX, is available for the Microsoft Windows operating system. An "on-line" version is also accessible on the World Wide Web. TPSX is designed to be a high-quality source for TPS material properties presented in a convenient, easily accessible form for use by engineers and researchers in the field of high-speed vehicle design. Data can be displayed and printed in several formats. An information window displays a brief description of the material with properties at standard pressure and temperature. A spread sheet window displays complete, detailed property information. Properties which are a function of temperature and/or pressure can be displayed as graphs. In any display the data can be converted from English to SI units with the click of a button. Two material databases included with TPSX are: 1) materials used and/or developed by the Thermal Protection Branch at NASA Ames Research Center, and 2) a database compiled by NASA Johnson Space Center 9JSC). The Ames database contains over 60 advanced TPS materials including flexible blankets, rigid ceramic tiles, and ultra-high temperature ceramics. The JSC database contains over 130 insulative and structural materials. The Ames database is periodically updated and expanded as required to include newly developed materials and material property refinements.

  11. CERN alerter—RSS based system for information broadcast to all CERN offices

    NASA Astrophysics Data System (ADS)

    Otto, R.

    2008-07-01

    Nearly every large organization uses a tool to broadcast messages and information across the internal campus (messages like alerts announcing interruption in services or just information about upcoming events). These tools typically allow administrators (operators) to send 'targeted' messages which are sent only to specific groups of users or computers, e/g only those located in a specified building or connected to a particular computing service. CERN has a long history of such tools: CERNVMS's SPM_quotMESSAGE command, Zephyr [2] and the most recent the NICE Alerter based on the NNTP protocol. The NICE Alerter used on all Windows-based computers had to be phased out as a consequence of phasing out NNTP at CERN. The new solution to broadcast information messages on the CERN campus continues to provide the service based on cross-platform technologies, hence minimizing custom developments and relying on commercial software as much as possible. The new system, called CERN Alerter, is based on RSS (Really Simple Syndication) [9] for the transport protocol and uses Microsoft SharePoint as the backend for database and posting interface. The windows-based client relies on Internet Explorer 7.0 with custom code to trigger the window pop-ups and the notifications for new events. Linux and Mac OS X clients could also rely on any RSS readers to subscribe to targeted notifications. The paper covers the architecture and implementation aspects of the new system.

  12. BERKELEY LAB WINDOW

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Curcija, Dragan Charlie; Zhu, Ling; Czarnecki, Stephen

    WINDOW features include: - Microsoft Windows TM interface - algorithms for the calculation of total fenestration product U-values and Solar Heat Gain Coefficient consistent with ASHRAE SPC 142, ISO 15099, and the National Fenestration Rating Council - a Condensation Resistance Index in accordance with the NFRC 500 Standard - and integrated database of properties - imports data from other LBNL window analysis software: - Import THERM file into the Frame Library - Import records from IGDB and OPtics5 into the Glass Library for the optical properties of coated and uncoated glazings, laminates, and applied films. Program Capabilities WINDOW 7.2 offersmore » the following features: The ability to analyze products made from any combination of glazing layers, gas layers, frames, spacers, and dividers under any environmental conditions and at any tilt; The ability to model complex glazing systems such as venetian blinds and roller shades. Directly accessible libraries of window system components, (glazing systems, glazing layers, gas fills, frame and divider elements), and environmental conditions; The choice of working in English (IP), or Systeme International (SI) units; The ability to specify the dimensions and thermal properties of each frame element (header, sills, jamb, mullion) in a window; A multi-band (wavelength-by-wavelength) spectral model; A Glass Library which can access spectral data files for many common glazing materials from the Optics5database; A night-sky radiative model; A link with the DOE-2.1E and Energy Plus building energy analysis program. Performance Indices and Other Results For a user-defined fenestration system and user-defined environmental conditions, WINDOW calculates: The U-value, solar heat gain coefficient, shading coefficient, and visible transmittance for the complete window system; The U-value, solar heat gain coefficient, shading coefficient, and visible transmittance for the glazing system (center-of-glass values); The U-values of the frame and divider elements and corresponding edge-of-glass areas (based on generic correlations); The total solar and visible transmittance and reflectances of the glazing system. Color properties, i.e. L*, a*, and b* color coordinates, dominant wavelength, and purity for transmitted and reflected (outdoor) solar radiation; The damage-weighted transmittance of the glazing system between 0.3 an 0.38 microns; The angular dependence of the solar and visible transmittances, solar and visible reflectances, solar absorptance, and solar heat gain coefficient of the glazing system; The percent relative humidity of the inside and outside air for which condensation will occur on the interior and exterior glazing surfaces respectively; The center-of-glass temperature distribution.« less

  13. imDEV: a graphical user interface to R multivariate analysis tools in Microsoft Excel

    PubMed Central

    Grapov, Dmitry; Newman, John W.

    2012-01-01

    Summary: Interactive modules for Data Exploration and Visualization (imDEV) is a Microsoft Excel spreadsheet embedded application providing an integrated environment for the analysis of omics data through a user-friendly interface. Individual modules enables interactive and dynamic analyses of large data by interfacing R's multivariate statistics and highly customizable visualizations with the spreadsheet environment, aiding robust inferences and generating information-rich data visualizations. This tool provides access to multiple comparisons with false discovery correction, hierarchical clustering, principal and independent component analyses, partial least squares regression and discriminant analysis, through an intuitive interface for creating high-quality two- and a three-dimensional visualizations including scatter plot matrices, distribution plots, dendrograms, heat maps, biplots, trellis biplots and correlation networks. Availability and implementation: Freely available for download at http://sourceforge.net/projects/imdev/. Implemented in R and VBA and supported by Microsoft Excel (2003, 2007 and 2010). Contact: John.Newman@ars.usda.gov Supplementary Information: Installation instructions, tutorials and users manual are available at http://sourceforge.net/projects/imdev/. PMID:22815358

  14. Institutional Transformation 2.5 Building Module Help Manual.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Villa, Daniel

    The Institutional Transformation (IX) building module is a software tool developed at Sandia National Laboratories to evaluate energy conservation measures (ECMs) on hundreds of DOE-2 building energy models simultaneously. In IX, ECMs can be designed through parameterizing DOE-2 building models and doing further processing via visual basic for applications subroutines. IX provides the functionality to handle multiple building models for different years, which enables incrementally changing a site of hundreds of buildings over time. It also enables evaluation of the effects of changing climate, comparisons between data and modeling results, and energy use of centralized utility buildings (CUBs). IX consistsmore » of a Microsoft Excel(r) user interface, Microsoft Access(r) database, and Microsoft Excel(r) CUB build utility whose functionalities are described in detail in this report. In addition to descriptions of the user interfaces, descriptions of every ECM already designed in IX is included. SAND2016-8983 IX 2.5 Help Manual« less

  15. Simplified Application of Material Efficiency Green Metrics to Synthesis Plans: Pedagogical Case Studies Selected from "Organic Syntheses"

    ERIC Educational Resources Information Center

    Andraos, John

    2015-01-01

    This paper presents a simplified approach for the application of material efficiency metrics to linear and convergent synthesis plans encountered in organic synthesis courses. Computations are facilitated and automated using intuitively designed Microsoft Excel spreadsheets without invoking abstract mathematical formulas. The merits of this…

  16. An Innovative Spreadsheet Application to Teach Management Science Decision Criteria

    ERIC Educational Resources Information Center

    Hozak, Kurt

    2018-01-01

    This article describes a Microsoft Excel-based application that uses humorous voice synthesis and timed competition to make it more fun and engaging to learn management science decision criteria. In addition to providing immediate feedback and easily customizable tips that facilitate self-learning, the software randomly generates both the problem…

  17. Comparing Learning Outcomes among Community-College Students Based on the Use of a Microsoft Word Simulator

    ERIC Educational Resources Information Center

    Felts, Renee R.

    2013-01-01

    As increasing numbers of students enroll in introductory computer application courses, instructors have difficulty providing the needed assistance in the traditional laboratory setting. Simulators have been used to facilitate college instruction, but the effectiveness of using a simulator in an introductory computer application course had not yet…

  18. Application for internal dosimetry using biokinetic distribution of photons based on nuclear medicine images*

    PubMed Central

    Leal Neto, Viriato; Vieira, José Wilson; Lima, Fernando Roberto de Andrade

    2014-01-01

    Objective This article presents a way to obtain estimates of dose in patients submitted to radiotherapy with basis on the analysis of regions of interest on nuclear medicine images. Materials and Methods A software called DoRadIo (Dosimetria das Radiações Ionizantes [Ionizing Radiation Dosimetry]) was developed to receive information about source organs and target organs, generating graphical and numerical results. The nuclear medicine images utilized in the present study were obtained from catalogs provided by medical physicists. The simulations were performed with computational exposure models consisting of voxel phantoms coupled with the Monte Carlo EGSnrc code. The software was developed with the Microsoft Visual Studio 2010 Service Pack and the project template Windows Presentation Foundation for C# programming language. Results With the mentioned tools, the authors obtained the file for optimization of Monte Carlo simulations using the EGSnrc; organization and compaction of dosimetry results with all radioactive sources; selection of regions of interest; evaluation of grayscale intensity in regions of interest; the file of weighted sources; and, finally, all the charts and numerical results. Conclusion The user interface may be adapted for use in clinical nuclear medicine as a computer-aided tool to estimate the administered activity. PMID:25741101

  19. Use of graph algorithms in the processing and analysis of images with focus on the biomedical data.

    PubMed

    Zdimalova, M; Roznovjak, R; Weismann, P; El Falougy, H; Kubikova, E

    2017-01-01

    Image segmentation is a known problem in the field of image processing. A great number of methods based on different approaches to this issue was created. One of these approaches utilizes the findings of the graph theory. Our work focuses on segmentation using shortest paths in a graph. Specifically, we deal with methods of "Intelligent Scissors," which use Dijkstra's algorithm to find the shortest paths. We created a new software in Microsoft Visual Studio 2013 integrated development environment Visual C++ in the language C++/CLI. We created a format application with a graphical users development environment for system Windows, with using the platform .Net (version 4.5). The program was used for handling and processing the original medical data. The major disadvantage of the method of "Intelligent Scissors" is the computational time length of Dijkstra's algorithm. However, after the implementation of a more efficient priority queue, this problem could be alleviated. The main advantage of this method we see in training that enables to adapt to a particular kind of edge, which we need to segment. The user involvement has a significant influence on the process of segmentation, which enormously aids to achieve high-quality results (Fig. 7, Ref. 13).

  20. WavePropaGator: interactive framework for X-ray free-electron laser optics design and simulations.

    PubMed

    Samoylova, Liubov; Buzmakov, Alexey; Chubar, Oleg; Sinn, Harald

    2016-08-01

    This article describes the WavePropaGator ( WPG ) package, a new interactive software framework for coherent and partially coherent X-ray wavefront propagation simulations. The package has been developed at European XFEL for users at the existing and emerging free-electron laser (FEL) facilities, as well as at the third-generation synchrotron sources and future diffraction-limited storage rings. The WPG addresses the needs of beamline scientists and user groups to facilitate the design, optimization and improvement of X-ray optics to meet their experimental requirements. The package uses the Synchrotron Radiation Workshop ( SRW ) C/C++ library and its Python binding for numerical wavefront propagation simulations. The framework runs reliably under Linux, Microsoft Windows 7 and Apple Mac OS X and is distributed under an open-source license. The available tools allow for varying source parameters and optics layouts and visualizing the results interactively. The wavefront history structure can be used for tracking changes in every particular wavefront during propagation. The batch propagation mode enables processing of multiple wavefronts in workflow mode. The paper presents a general description of the package and gives some recent application examples, including modeling of full X-ray FEL beamlines and start-to-end simulation of experiments.

  1. Leveraging Pattern Semantics for Extracting Entities in Enterprises

    PubMed Central

    Tao, Fangbo; Zhao, Bo; Fuxman, Ariel; Li, Yang; Han, Jiawei

    2015-01-01

    Entity Extraction is a process of identifying meaningful entities from text documents. In enterprises, extracting entities improves enterprise efficiency by facilitating numerous applications, including search, recommendation, etc. However, the problem is particularly challenging on enterprise domains due to several reasons. First, the lack of redundancy of enterprise entities makes previous web-based systems like NELL and OpenIE not effective, since using only high-precision/low-recall patterns like those systems would miss the majority of sparse enterprise entities, while using more low-precision patterns in sparse setting also introduces noise drastically. Second, semantic drift is common in enterprises (“Blue” refers to “Windows Blue”), such that public signals from the web cannot be directly applied on entities. Moreover, many internal entities never appear on the web. Sparse internal signals are the only source for discovering them. To address these challenges, we propose an end-to-end framework for extracting entities in enterprises, taking the input of enterprise corpus and limited seeds to generate a high-quality entity collection as output. We introduce the novel concept of Semantic Pattern Graph to leverage public signals to understand the underlying semantics of lexical patterns, reinforce pattern evaluation using mined semantics, and yield more accurate and complete entities. Experiments on Microsoft enterprise data show the effectiveness of our approach. PMID:26705540

  2. Leveraging Pattern Semantics for Extracting Entities in Enterprises.

    PubMed

    Tao, Fangbo; Zhao, Bo; Fuxman, Ariel; Li, Yang; Han, Jiawei

    2015-05-01

    Entity Extraction is a process of identifying meaningful entities from text documents. In enterprises, extracting entities improves enterprise efficiency by facilitating numerous applications, including search, recommendation, etc. However, the problem is particularly challenging on enterprise domains due to several reasons. First, the lack of redundancy of enterprise entities makes previous web-based systems like NELL and OpenIE not effective, since using only high-precision/low-recall patterns like those systems would miss the majority of sparse enterprise entities, while using more low-precision patterns in sparse setting also introduces noise drastically. Second, semantic drift is common in enterprises ("Blue" refers to "Windows Blue"), such that public signals from the web cannot be directly applied on entities. Moreover, many internal entities never appear on the web. Sparse internal signals are the only source for discovering them. To address these challenges, we propose an end-to-end framework for extracting entities in enterprises, taking the input of enterprise corpus and limited seeds to generate a high-quality entity collection as output. We introduce the novel concept of Semantic Pattern Graph to leverage public signals to understand the underlying semantics of lexical patterns, reinforce pattern evaluation using mined semantics, and yield more accurate and complete entities. Experiments on Microsoft enterprise data show the effectiveness of our approach.

  3. Lyme Disease Data

    MedlinePlus

    ... County-level Lyme disease data from 2000-2016 Microsoft Excel file [Excel CSV – 209KB] ––Right–click the link ... PDF file Microsoft PowerPoint file Microsoft Word file Microsoft Excel file Audio/Video file Apple Quicktime file RealPlayer ...

  4. IDEOM: an Excel interface for analysis of LC-MS-based metabolomics data.

    PubMed

    Creek, Darren J; Jankevics, Andris; Burgess, Karl E V; Breitling, Rainer; Barrett, Michael P

    2012-04-01

    The application of emerging metabolomics technologies to the comprehensive investigation of cellular biochemistry has been limited by bottlenecks in data processing, particularly noise filtering and metabolite identification. IDEOM provides a user-friendly data processing application that automates filtering and identification of metabolite peaks, paying particular attention to common sources of noise and false identifications generated by liquid chromatography-mass spectrometry (LC-MS) platforms. Building on advanced processing tools such as mzMatch and XCMS, it allows users to run a comprehensive pipeline for data analysis and visualization from a graphical user interface within Microsoft Excel, a familiar program for most biological scientists. IDEOM is provided free of charge at http://mzmatch.sourceforge.net/ideom.html, as a macro-enabled spreadsheet (.xlsb). Implementation requires Microsoft Excel (2007 or later). R is also required for full functionality. michael.barrett@glasgow.ac.uk Supplementary data are available at Bioinformatics online.

  5. Measuring Waves and Erosion in Underwater Oil Blobs and Monitoring Other Arbitrary Surfaces with a Kinect v2 Time-of-Flight Camera

    NASA Astrophysics Data System (ADS)

    Butkiewicz, T.

    2014-12-01

    We developed free software that enables researchers to utilize Microsoft's new Kinect for Windows v2 sensor for a range of coastal and ocean mapping applications, as well as monitoring and measuring experimental scenes. While the original Kinect device used structured light and had very poor resolution, many geophysical researchers found uses for it in their experiments. The new next generation of this sensor uses time-of-flight technology, and can produce higher resolution depth measurements with an order of magnitude more accuracy. It also is capable of measurement through and under water. An analysis tool in our application lets users quickly select any arbitrary surface in the sensor's view. The tools automatically scans the surface, then calibrates and aligns a measurement volume to it. Depth readings from the sensor are converted into 3D point clouds, and points falling within this volume are projected into surface coordinates. Raster images can be output which consist of height fields aligned to the surface, generated from these projected measurements and interpolations between them. Images have a simple 1 pixel = 1 mm resolution and intensity values representing mm in height from the base-plane, which enables easy measurement and calculations to be conducted on the images in other analysis packages. Single snapshots can be taken manually on demand, or the software can monitor the surface automatically, capturing frames at preset intervals. This produces time lapse animations of dynamically changing surfaces. We apply this analysis tool to an experiment studying the behavior of underwater oil in response to flowing water of different speeds and temperatures. Blobs of viscous oils are placed in a flume apparatus, which circulates water past them. Over the course of a couple hours, the oil blobs spread out, waves slowly ripple across their surfaces, and erosions occur as smaller blobs break off from the main blob. All of this can be captured in 3D, with mm accuracy, through the water using the Kinect for Windows v2 sensor and our K2MapKit software.

  6. Scale up of large ALON® and spinel windows

    NASA Astrophysics Data System (ADS)

    Goldman, Lee M.; Kashalikar, Uday; Ramisetty, Mohan; Jha, Santosh; Sastri, Suri

    2017-05-01

    Aluminum Oxynitride (ALON® Transparent Ceramic) and Magnesia Aluminate Spinel (Spinel) combine broadband transparency with excellent mechanical properties. Their cubic structure means that they are transparent in their polycrystalline form, allowing them to be manufactured by conventional powder processing techniques. Surmet has scaled up its ALON® production capability to produce and deliver windows as large as 4.4 sq ft. We have also produced our first 6 sq ft window. We are in the process of producing 7 sq ft ALON® window blanks for armor applications; and scale up to even larger, high optical quality blanks for Recce window applications is underway. Surmet also produces spinel for customers that require superior transmission at the longer wavelengths in the mid wave infra-red (MWIR). Spinel windows have been limited to smaller sizes than have been achieved with ALON. To date the largest spinel window produced is 11x18-in, and windows 14x20-in size are currently in process. Surmet is now scaling up its spinel processing capability to produce high quality window blanks as large as 19x27-in for sensor applications.

  7. Matching the best viewing angle in depth cameras for biomass estimation based on poplar seedling geometry.

    PubMed

    Andújar, Dionisio; Fernández-Quintanilla, César; Dorado, José

    2015-06-04

    In energy crops for biomass production a proper plant structure is important to optimize wood yields. A precise crop characterization in early stages may contribute to the choice of proper cropping techniques. This study assesses the potential of the Microsoft Kinect for Windows v.1 sensor to determine the best viewing angle of the sensor to estimate the plant biomass based on poplar seedling geometry. Kinect Fusion algorithms were used to generate a 3D point cloud from the depth video stream. The sensor was mounted in different positions facing the tree in order to obtain depth (RGB-D) images from different angles. Individuals of two different ages, e.g., one month and one year old, were scanned. Four different viewing angles were compared: top view (0°), 45° downwards view, front view (90°) and ground upwards view (-45°). The ground-truth used to validate the sensor readings consisted of a destructive sampling in which the height, leaf area and biomass (dry weight basis) were measured in each individual plant. The depth image models agreed well with 45°, 90° and -45° measurements in one-year poplar trees. Good correlations (0.88 to 0.92) between dry biomass and the area measured with the Kinect were found. In addition, plant height was accurately estimated with a few centimeters error. The comparison between different viewing angles revealed that top views showed poorer results due to the fact the top leaves occluded the rest of the tree. However, the other views led to good results. Conversely, small poplars showed better correlations with actual parameters from the top view (0°). Therefore, although the Microsoft Kinect for Windows v.1 sensor provides good opportunities for biomass estimation, the viewing angle must be chosen taking into account the developmental stage of the crop and the desired parameters. The results of this study indicate that Kinect is a promising tool for a rapid canopy characterization, i.e., for estimating crop biomass production, with several important advantages: low cost, low power needs and a high frame rate (frames per second) when dynamic measurements are required.

  8. Xyce Parallel Electronic Simulator Users' Guide Version 6.7.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keiter, Eric R.; Aadithya, Karthik Venkatraman; Mei, Ting

    This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been designed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: Capability to solve extremely large circuit problems by supporting large-scale parallel com- puting platforms (up to thousands of processors). This includes support for most popular parallel and serial computers. A differential-algebraic-equation (DAE) formulation, which better isolates the device model package from solver algorithms. This allows one tomore » develop new types of analysis without requiring the implementation of analysis-specific device models. Device models that are specifically tailored to meet Sandia's needs, including some radiation- aware devices (for Sandia users only). Object-oriented code design and implementation using modern coding practices. Xyce is a parallel code in the most general sense of the phrase -- a message passing parallel implementation -- which allows it to run efficiently a wide range of computing platforms. These include serial, shared-memory and distributed-memory parallel platforms. Attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows. The information herein is subject to change without notice. Copyright c 2002-2017 Sandia Corporation. All rights reserved. Trademarks Xyce TM Electronic Simulator and Xyce TM are trademarks of Sandia Corporation. Orcad, Orcad Capture, PSpice and Probe are registered trademarks of Cadence Design Systems, Inc. Microsoft, Windows and Windows 7 are registered trademarks of Microsoft Corporation. Medici, DaVinci and Taurus are registered trademarks of Synopsys Corporation. Amtec and TecPlot are trademarks of Amtec Engineering, Inc. All other trademarks are property of their respective owners. Contacts World Wide Web http://xyce.sandia.gov https://info.sandia.gov/xyce (Sandia only) Email xyce@sandia.gov (outside Sandia) xyce-sandia@sandia.gov (Sandia only) Bug Reports (Sandia only) http://joseki-vm.sandia.gov/bugzilla http://morannon.sandia.gov/bugzilla« less

  9. Users guide for WoodCite, a product cost quotation tool for wood component manufacturers [computer program

    Treesearch

    Jeff Palmer; Adrienn Andersch; Jan Wiedenbeck; Urs. Buehlmann

    2014-01-01

    WoodCite is a Microsoft® Access-based application that allows wood component manufacturers to develop product price quotations for their current and potential customers. The application was developed by the U.S. Forest Service and Virginia Polytechnic Institute and State University, in cooperation with the Wood Components Manufacturers Association.

  10. Preparing Content-Rich Learning Environments with VPython and Excel, Controlled by Visual Basic for Applications

    ERIC Educational Resources Information Center

    Prayaga, Chandra

    2008-01-01

    A simple interface between VPython and Microsoft (MS) Office products such as Word and Excel, controlled by Visual Basic for Applications, is described. The interface allows the preparation of content-rich, interactive learning environments by taking advantage of the three-dimensional (3D) visualization capabilities of VPython and the GUI…

  11. Augmented Reality Technology Using Microsoft HoloLens in Anatomic Pathology.

    PubMed

    Hanna, Matthew G; Ahmed, Ishtiaque; Nine, Jeffrey; Prajapati, Shyam; Pantanowitz, Liron

    2018-05-01

    Context Augmented reality (AR) devices such as the Microsoft HoloLens have not been well used in the medical field. Objective To test the HoloLens for clinical and nonclinical applications in pathology. Design A Microsoft HoloLens was tested for virtual annotation during autopsy, viewing 3D gross and microscopic pathology specimens, navigating whole slide images, telepathology, as well as real-time pathology-radiology correlation. Results Pathology residents performing an autopsy wearing the HoloLens were remotely instructed with real-time diagrams, annotations, and voice instruction. 3D-scanned gross pathology specimens could be viewed as holograms and easily manipulated. Telepathology was supported during gross examination and at the time of intraoperative consultation, allowing users to remotely access a pathologist for guidance and to virtually annotate areas of interest on specimens in real-time. The HoloLens permitted radiographs to be coregistered on gross specimens and thereby enhanced locating important pathologic findings. The HoloLens also allowed easy viewing and navigation of whole slide images, using an AR workstation, including multiple coregistered tissue sections facilitating volumetric pathology evaluation. Conclusions The HoloLens is a novel AR tool with multiple clinical and nonclinical applications in pathology. The device was comfortable to wear, easy to use, provided sufficient computing power, and supported high-resolution imaging. It was useful for autopsy, gross and microscopic examination, and ideally suited for digital pathology. Unique applications include remote supervision and annotation, 3D image viewing and manipulation, telepathology in a mixed-reality environment, and real-time pathology-radiology correlation.

  12. Simulation of complex pharmacokinetic models in Microsoft Excel.

    PubMed

    Meineke, Ingolf; Brockmöller, Jürgen

    2007-12-01

    With the arrival of powerful personal computers in the office numerical methods are accessible to everybody. Simulation of complex processes therefore has become an indispensible tool in research and education. In this paper Microsoft EXCEL is used as a platform for a universal differential equation solver. The software is designed as an add-in aiming at a minimum of required user input to perform a given task. Four examples are included to demonstrate both, the simplicity of use and the versatility of possible applications. While the layout of the program is admittedly geared to the needs of pharmacokineticists, it can be used in any field where sets of differential equations are involved. The software package is available upon request.

  13. 75 FR 10455 - Broadband Initiatives Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-08

    ... Application Window for Notice of Funds Availability (NOFA) and solicitation of applications. SUMMARY: On...). In response to requests by a wide variety of stakeholders, RUS is extending the application window...

  14. What's New with MS Office Suites

    ERIC Educational Resources Information Center

    Goldsborough, Reid

    2012-01-01

    If one buys a new PC, laptop, or netbook computer today, it probably comes preloaded with Microsoft Office 2010 Starter Edition. This is a significantly limited, advertising-laden version of Microsoft's suite of productivity programs, Microsoft Office. This continues the trend of PC makers providing ever more crippled versions of Microsoft's…

  15. Utilizing Microsoft Mathematics in Teaching and Learning Calculus

    ERIC Educational Resources Information Center

    Oktaviyanthi, Rina; Supriani, Yani

    2015-01-01

    The experimental design was conducted to investigate the use of Microsoft Mathematics, free software made by Microsoft Corporation, in teaching and learning Calculus. This paper reports results from experimental study details on implementation of Microsoft Mathematics in Calculus, students' achievement and the effects of the use of Microsoft…

  16. Experimental Design: Utilizing Microsoft Mathematics in Teaching and Learning Calculus

    ERIC Educational Resources Information Center

    Oktaviyanthi, Rina; Supriani, Yani

    2015-01-01

    The experimental design was conducted to investigate the use of Microsoft Mathematics, free software made by Microsoft Corporation, in teaching and learning Calculus. This paper reports results from experimental study details on implementation of Microsoft Mathematics in Calculus, students' achievement and the effects of the use of Microsoft…

  17. Software Re-Engineering of the Human Factors Analysis and Classification System - (Maintenance Extension) Using Object Oriented Methods in a Microsoft Environment

    DTIC Science & Technology

    2001-09-01

    replication) -- all from Visual Basic and VBA . In fact, we found that the SQL Server engine actually had a plethora of options, most formidable of...2002, the new SQL Server 2000 database engine, and Microsoft Visual Basic.NET. This thesis describes our use of the Spiral Development Model to...versions of Microsoft products? Specifically, the pending release of Microsoft Office 2002, the new SQL Server 2000 database engine, and Microsoft

  18. USER'S GUIDE FOR THE MUNICIPAL SOLID WASTE LIFE-CYCLE DATABASE

    EPA Science Inventory

    The report describes how to use the municipal solid waste (MSW) life cycle database, a software application with Microsoft Access interfaces, that provides environmental data for energy production, materials production, and MSW management activities and equipment. The basic datab...

  19. Aquarius - A Modelling Package for Groundwater Flow and Coupled Heat Transport in the Range 0.1 to 100 MPa and 0.1 to 1000 C

    NASA Astrophysics Data System (ADS)

    Cook, S. J.

    2009-05-01

    Aquarius is a Windows application that models fluid flow and heat transport under conditions in which fluid buoyancy can significantly impact patterns and magnitudes of fluid flow. The package is designed as a visualization tool through which users can examine flow systems in environments, both low temperature aquifers and regions with elevated PT regimes such as deep sedimentary basins, hydrothermal systems, and contact thermal aureoles. The package includes 4 components: (1) A finite-element mesh generator/assembler capable of representing complex geologic structures. Left-hand, right-hand and alternating linear triangles can be mixed within the mesh. Planer horizontal, planer vertical and cylindrical vertical coordinate sections are supported. (2) A menu-selectable system for setting properties and boundary/initial conditions. The design retains mathematical terminology for all input parameters such as scalars (e.g., porosity), tensors (e.g., permeability), and boundary/initial conditions (e.g., fixed potential). This makes the package an effective instructional aide by linking model requirements with the underlying mathematical concepts of partial differential equations and the solution logic of boundary/initial value problems. (3) Solution algorithms for steady-state and time-transient fluid flow/heat transport problems. For all models, the nonlinear global matrix equations are solved sequentially using over-relaxation techniques. Matrix storage design allows for large (e.g., 20000) element models to run efficiently on a typical PC. (4) A plotting system that supports contouring nodal data (e.g., head), vector plots for flux data (e.g., specific discharge), and colour gradient plots for elemental data (e.g., porosity), water properties (e.g., density), and performance measures (e.g., Peclet numbers). Display graphics can be printed or saved in standard graphic formats (e.g., jpeg). This package was developed from procedural codes in C written originally to model the hydrothermal flow system responsible for contact metamorphism of Utah's Alta Stock (Cook et al., AJS 1997). These codes were reprogrammed in Microsoft C# to take advantage of object oriented design and the capabilities of Microsoft's .NET framework. The package is available at no cost by e-mail request from the author.

  20. Using web-based video to enhance physical examination skills in medical students.

    PubMed

    Orientale, Eugene; Kosowicz, Lynn; Alerte, Anton; Pfeiffer, Carol; Harrington, Karen; Palley, Jane; Brown, Stacey; Sapieha-Yanchak, Teresa

    2008-01-01

    Physical examination (PE) skills among U.S. medical students have been shown to be deficient. This study examines the effect of a Web-based physical examination curriculum on first-year medical student PE skills. Web-based video clips, consisting of instruction in 77 elements of the physical examination, were created using Microsoft Windows Moviemaker software. Medical students' PE skills were evaluated by standardized patients before and after implementation of the Internet-based video. Following implementation of this curriculum, there was a higher level of competency (from 87% in 2002-2003 to 91% in 2004-2005), and poor performances on standardized patient PE exams substantially diminished (from a 14%-22%failure rate in 2002-2003, to 4% in 2004-2005. A significant improvement in first-year medical student performance on the adult PE occurred after implementing Web-based instructional video.

  1. SwarmSight: Measuring the Temporal Progression of Animal Group Activity Levels from Natural Scene and Laboratory Videos

    PubMed Central

    Birgiolas, Justas; Jernigan, Christopher M.; Smith, Brian H.; Crook, Sharon M.

    2016-01-01

    We describe SwarmSight (available at: https://github.com/justasb/SwarmSight), a novel, open-source, Microsoft Windows software tool for quantitative assessment of the temporal progression of animal group activity levels from recorded videos. The tool utilizes a background subtraction machine vision algorithm and provides an activity metric that can be used to quantitatively assess and compare animal group behavior. Here we demonstrate the tool utility by analyzing defensive bee behavior as modulated by alarm pheromones, wild bird feeding onset and interruption, and cockroach nest finding activity. While more sophisticated, commercial software packages are available, SwarmSight provides a low-cost, open-source, and easy-to-use alternative that is suitable for a wide range of users, including minimally trained research technicians and behavioral science undergraduate students in classroom laboratory settings. PMID:27130170

  2. How to make your own response boxes: A step-by-step guide for the construction of reliable and inexpensive parallel-port response pads from computer mice.

    PubMed

    Voss, Andreas; Leonhart, Rainer; Stahl, Christoph

    2007-11-01

    Psychological research is based in large parts on response latencies, which are often registered by keypresses on a standard computer keyboard. Recording response latencies with a standard keyboard is problematic because keypresses are buffered within the keyboard hardware before they are signaled to the computer, adding error variance to the recorded latencies. This can be circumvented by using external response pads connected to the computer's parallel port. In this article, we describe how to build inexpensive, reliable, and easy-to-use response pads with six keys from two standard computer mice that can be connected to the PC's parallel port. We also address the problem of recording data from the parallel port with different software packages under Microsoft's Windows XP.

  3. A Multidisciplinary Tool for Systems Analysis of Planetary Entry, Descent, and Landing (SAPE)

    NASA Technical Reports Server (NTRS)

    Samareh, Jamshid A.

    2009-01-01

    SAPE is a Python-based multidisciplinary analysis tool for systems analysis of planetary entry, descent, and landing (EDL) for Venus, Earth, Mars, Jupiter, Saturn, Uranus, Neptune, and Titan. The purpose of SAPE is to provide a variable-fidelity capability for conceptual and preliminary analysis within the same framework. SAPE includes the following analysis modules: geometry, trajectory, aerodynamics, aerothermal, thermal protection system, and structural sizing. SAPE uses the Python language-a platform-independent open-source software for integration and for the user interface. The development has relied heavily on the object-oriented programming capabilities that are available in Python. Modules are provided to interface with commercial and government off-the-shelf software components (e.g., thermal protection systems and finite-element analysis). SAPE runs on Microsoft Windows and Apple Mac OS X and has been partially tested on Linux.

  4. The Functional Measurement Experiment Builder suite: two Java-based programs to generate and run functional measurement experiments.

    PubMed

    Mairesse, Olivier; Hofmans, Joeri; Theuns, Peter

    2008-05-01

    We propose a free, easy-to-use computer program that does not requires prior knowledge of computer programming to generate and run experiments using textual or pictorial stimuli. Although the FM Experiment Builder suite was initially programmed for building and conducting FM experiments, it can also be applied for non-FM experiments that necessitate randomized, single, or multifactorial designs. The program is highly configurable, allowing multilingual use and a wide range of different response formats. The outputs of the experiments are Microsoft Excel compatible .xls files that allow easy copy-paste of the results into Weiss's FM CalSTAT program (2006) or any other statistical package. Its Java-based structure is compatible with both Windows and Macintosh operating systems, and its compactness (< 1 MB) makes it easily distributable over the Internet.

  5. Microsoft in Southeast Europe: A Conversation with Goran Radman

    ERIC Educational Resources Information Center

    Pendergast, William; Frayne, Colette; Kelley, Patricia

    2009-01-01

    Goran Radman (GR) joined Microsoft in 1996 and served until Fall 2008 as Microsoft Chairman, Southeast Europe (SEE) and Chairman, East and Central Europe (ECEE). Based in Croatia, where he enjoys sailing the Adriatic coast and islands, he spoke with the authors during 2008 and 2009 about his experience launching Microsoft's commercial presence in…

  6. Microsoft's Tom Corddry on Multimedia, the Information Superhighway and the Future of Online.

    ERIC Educational Resources Information Center

    Herther, Nancy K.

    1994-01-01

    Tom Corddry, Microsoft Corporation's Creative Director for the Consumer Division, is interviewed about the Microsoft Home line of products and the development of related CD-ROM and multimedia products. Reasons for Microsoft's entry into the content market and its challenges, the market's future, and the company's interest in developing online…

  7. A novel web-enabled healthcare solution on health vault system.

    PubMed

    Liao, Lingxia; Chen, Min; Rodrigues, Joel J P C; Lai, Xiaorong; Vuong, Son

    2012-06-01

    Complicated Electronic Medical Records (EMR) systems have created problems in systems regarding an easy implementation and interoperability for a Web-enabled Healthcare Solution, which is normally provided by an independent healthcare giver with limited IT knowledge and interests. An EMR system with well-designed and user-friendly interface, such as Microsoft HealthVault System used as the back-end platform of a Web-enabled healthcare application will be an approach to deal with these problems. This paper analyzes the patient oriented Web-enabled healthcare service application as the new trend to delivery healthcare from hospital/clinic-centric to patient-centric, the current e-healthcare applications, and the main backend EMR systems. Then, we present a novel web-enabled healthcare solution based on Microsoft HealthVault EMR system to meet customers' needs, such as, low total cost, easily development and maintenance, and good interoperability. A sample system is given to show how the solution can be fulfilled, evaluated, and validated. We expect that this paper will provide a deep understanding of the available EMR systems, leading to insights for new solutions and approaches driven to next generation EMR systems.

  8. Prevalence of early loss of primary teeth in 5-10-year-old school children in Chidambaram town.

    PubMed

    Ahamed, S Syed Shaheed; Reddy, Venugopal N; Krishnakumar, R; Mohan, Muthu G; Sugumaran, Durai K; Rao, Arun P

    2012-01-01

    The premature loss of primary teeth may reduce arch length required for the succeeding tooth and, hence, predisposes crowding, rotation and impaction of the permanent teeth. There are only limited studies carried out about the prevalence of early loss of primary teeth. The present study was performed to evaluate the prevalence of early loss of primary teeth in school children in Chidambaram town in Tamilnadu, India. A total of 1121 school children (561 boys and 560 girls) between 5 and 10 years of age were selected for the study. An experienced examiner performed all clinical examinations under natural light. Data including age and missing tooth was collected. Microsoft Excel/2000 (Microsoft Office XP) data spreadsheet was used and later exported to the Statistical Package for Social Science (SPSS) for Windows (version 10.0). Descriptive statistics was applied and, from the results, chi-square tests were applied at a level of significance of 5% (P < 0.05). The results showed that 16.5% of the sample had early loss of primary teeth, but no differences were observed between genders (P > 0.05). The greatest prevalence was found among the 8-year olds (5.08%), and the most commonly missing teeth were the right lower primary first molars (16.82%). It can be concluded that the prevalence of early loss was high and that the lower primary molars were the most commonly missing teeth in the present study.

  9. 47 CFR 73.871 - Amendment of LPFM broadcast station applications.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... limitation during the pertinent filing window. (b) Amendments that would improve the comparative position of new and major change applications will not be accepted after the close of the pertinent filing window... the pertinent filing window. Subject to the provisions of this section, such amendments may be filed...

  10. Application programming in C# environment with recorded user software interactions and its application in autopilot of VMAT/IMRT treatment planning.

    PubMed

    Wang, Henry; Xing, Lei

    2016-11-08

    An autopilot scheme of volumetric-modulated arc therapy (VMAT)/intensity-modulated radiation therapy (IMRT) planning with the guidance of prior knowl-edge is established with recorded interactions between a planner and a commercial treatment planning system (TPS). Microsoft (MS) Visual Studio Coded UI is applied to record some common planner-TPS interactions as subroutines. The TPS used in this study is a Windows-based Eclipse system. The interactions of our application program with Eclipse TPS are realized through a series of subrou-tines obtained by prerecording the mouse clicks or keyboard strokes of a planner in operating the TPS. A strategy to autopilot Eclipse VMAT/IMRT plan selection process is developed as a specific example of the proposed "scripting" method. The autopiloted planning is navigated by a decision function constructed with a reference plan that has the same prescription and similar anatomy with the case at hand. The calculation proceeds by alternating between the Eclipse optimization and the outer-loop optimization independent of the Eclipse. In the C# program, the dosimetric characteristics of a reference treatment plan are used to assess and modify the Eclipse planning parameters and to guide the search for a clinically sensible treatment plan. The approach is applied to plan a head and neck (HN) VMAT case and a prostate IMRT case. Our study demonstrated the feasibility of application programming method in C# environment with recorded interactions of planner-TPS. The process mimics a planner's planning process and automatically provides clinically sensible treatment plans that would otherwise require a large amount of manual trial and error of a planner. The proposed technique enables us to harness a commercial TPS by application programming via the use of recorded human computer interactions and provides an effective tool to greatly facilitate the treatment planning process. © 2016 The Authors.

  11. 77 FR 26241 - Announcement of Grant Application Deadlines and Funding Levels

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-03

    ... window for Fiscal Year (FY) 2012. In addition, RUS announces the minimum and maximum amounts for... supplement existing projects are welcomed (grant applications must be submitted during the application window...

  12. MEA-Tools: an open source toolbox for the analysis of multi-electrode data with MATLAB.

    PubMed

    Egert, U; Knott, Th; Schwarz, C; Nawrot, M; Brandt, A; Rotter, S; Diesmann, M

    2002-05-30

    Recent advances in electrophysiological techniques have created new tools for the acquisition and storage of neuronal activity recorded simultaneously with numerous electrodes. These techniques support the analysis of the function as well as the structure of individual electrogenic cells in the context of surrounding neuronal or cardiac network. Commercially available tools for the analysis of such data, however, cannot be easily adapted to newly emerging requirements for data analysis and visualization, and cross compatibility between them is limited. In this report we introduce a free open source toolbox called microelectrode array tools (MEA-Tools) for the analysis of multi-electrode data based on the common data analysis environment MATLAB (version 5.3-6.1, The Mathworks, Natick, MA). The toolbox itself is platform independent. The file interface currently supports files recorded with MCRack (Multi Channel Systems, Reutlingen, Germany) under Microsoft Windows 95, 98, NT, and 2000, but can be adapted to other data acquisition systems. Functions are controlled via command line input and graphical user interfaces, and support common requirements for the analysis of local field potentials, extracellular spike activity, and continuous recordings, in addition to supplementary data acquired by additional instruments, e.g. intracellular amplifiers. Data may be processed as continuous recordings or time windows triggered to some event.

  13. 75 FR 14401 - Amendment of Certain of the Commission's Rules of Practice and Procedure and Rules of Commission...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-25

    ... were created, such as Microsoft Excel, Microsoft Word, or Microsoft PowerPoint (``native format'')? We... (condensed) or expanded (detailed) format Export search results to Excel or PDF As noted above, system is...., Microsoft Word ``.doc'' format or non-copy protected text- searchable ``.pdf'' format)? Should submissions...

  14. Quantitative thermodynamic predication of interactions between nucleic acid and non-nucleic acid species using Microsoft excel.

    PubMed

    Zou, Jiaqi; Li, Na

    2013-09-01

    Proper design of nucleic acid sequences is crucial for many applications. We have previously established a thermodynamics-based quantitative model to help design aptamer-based nucleic acid probes by predicting equilibrium concentrations of all interacting species. To facilitate customization of this thermodynamic model for different applications, here we present a generic and easy-to-use platform to implement the algorithm of the model with Microsoft(®) Excel formulas and VBA (Visual Basic for Applications) macros. Two Excel spreadsheets have been developed: one for the applications involving only nucleic acid species, the other for the applications involving both nucleic acid and non-nucleic acid species. The spreadsheets take the nucleic acid sequences and the initial concentrations of all species as input, guide the user to retrieve the necessary thermodynamic constants, and finally calculate equilibrium concentrations for all species in various bound and unbound conformations. The validity of both spreadsheets has been verified by comparing the modeling results with the experimental results on nucleic acid sequences reported in the literature. This Excel-based platform described here will allow biomedical researchers to rationalize the sequence design of nucleic acid probes using the thermodynamics-based modeling even without relevant theoretical and computational skills. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  15. Using Microsoft Access: A How-To-Do-It Manual for Librarians. How-To-Do-It Manuals for Librarians, Number 76.

    ERIC Educational Resources Information Center

    Butler, E. Sonny

    Much of what librarians do today requires adeptness in creating and manipulating databases. Many new computers bought by libraries every year come packaged with Microsoft Office and include Microsoft Access. This database program features a seamless interface between Microsoft Office's other programs like Word, Excel, and PowerPoint. This book…

  16. A mobile information management system used in textile enterprises

    NASA Astrophysics Data System (ADS)

    Huang, C.-R.; Yu, W.-D.

    2008-02-01

    The mobile information management system (MIMS) for textile enterprises is based on Microsoft Visual Studios. NET2003 Server, Microsoft SQL Server 2000, C++ language and wireless application protocol (WAP) and wireless markup language (WML) technology. The portable MIMS is composed of three-layer structures, i.e. showing layer; operating layer; and data visiting layer corresponding to the port-link module; processing module; and database module. By using the MIMS, not only the information exchanges become more convenient and easier, but also the compatible between the giant information capacity and a micro-cell phone and functional expansion nature in operating and designing can be realized by means of build-in units. The development of MIMS is suitable for the utilization in textile enterprises.

  17. Towards a detailed anthropometric body characterization using the Microsoft Kinect.

    PubMed

    Domingues, Ana; Barbosa, Filipa; Pereira, Eduardo M; Santos, Márcio Borgonovo; Seixas, Adérito; Vilas-Boas, João; Gabriel, Joaquim; Vardasca, Ricardo

    2016-01-01

    Anthropometry has been widely used in different fields, providing relevant information for medicine, ergonomics and biometric applications. However, the existent solutions present marked disadvantages, reducing the employment of this type of evaluation. Studies have been conducted in order to easily determine anthropometric measures considering data provided by low-cost sensors, such as the Microsoft Kinect. In this work, a methodology is proposed and implemented for estimating anthropometric measures considering the information acquired with this sensor. The measures obtained with this method were compared with the ones from a validation system, Qualisys. Comparing the relative errors determined with state-of-art references, for some of the estimated measures, lower errors were verified and a more complete characterization of the whole body structure was achieved.

  18. [Development and application of emergency medical information management system].

    PubMed

    Wang, Fang; Zhu, Baofeng; Chen, Jianrong; Wang, Jian; Gu, Chaoli; Liu, Buyun

    2011-03-01

    To meet the needs of clinical practice of rescuing critical illness and develop the information management system of the emergency medicine. Microsoft Visual FoxPro, which is one of Microsoft's visual programming tool, is used to develop computer-aided system included the information management system of the emergency medicine. The system mainly consists of the module of statistic analysis, the module of quality control of emergency rescue, the module of flow path of emergency rescue, the module of nursing care in emergency rescue, and the module of rescue training. It can realize the system management of emergency medicine and,process and analyze the emergency statistical data. This system is practical. It can optimize emergency clinical pathway, and meet the needs of clinical rescue.

  19. Macros for Educational Research.

    ERIC Educational Resources Information Center

    Woodrow, Janice E. J.

    1988-01-01

    Describes the design and operation of two macros written in the programming language of Microsoft's EXCEL for educational research applications. The first macro determines the frequency of responses to a Likert-type questionnaire or multiple-choice test; the second performs a one-way analysis of variance test. (Author/LRW)

  20. Automated delineation and characterization of watersheds for more than 3,000 surface-water-quality monitoring stations active in 2010 in Texas

    USGS Publications Warehouse

    Archuleta, Christy-Ann M.; Gonzales, Sophia L.; Maltby, David R.

    2012-01-01

    The U.S. Geological Survey (USGS), in cooperation with the Texas Commission on Environmental Quality, developed computer scripts and applications to automate the delineation of watershed boundaries and compute watershed characteristics for more than 3,000 surface-water-quality monitoring stations in Texas that were active during 2010. Microsoft Visual Basic applications were developed using ArcGIS ArcObjects to format the source input data required to delineate watershed boundaries. Several automated scripts and tools were developed or used to calculate watershed characteristics using Python, Microsoft Visual Basic, and the RivEX tool. Automated methods were augmented by the use of manual methods, including those done using ArcMap software. Watershed boundaries delineated for the monitoring stations are limited to the extent of the Subbasin boundaries in the USGS Watershed Boundary Dataset, which may not include the total watershed boundary from the monitoring station to the headwaters.

  1. Lagrangian technique to calculate window interface velocity from shock velocity measurements: Application for quartz windows

    DOE PAGES

    McCoy, Chad A.; Knudson, Marcus D.

    2017-08-24

    Measurement of the window interface velocity is a common technique for investigating the dynamic response materials at high strain rates. However, these measurements are limited in pressure to the range where the window remains transparent. The most common window material for this application is lithium fluoride, which under single shock compression becomes opaque at ~200 GPa. To date, no other window material has been identified for use at higher pressures. Here, we present a Lagrangian technique to calculate the interface velocity from a continuously measured shock velocity, with application to quartz. The quartz shock front becomes reflective upon melt, atmore » ~100 GPa, enabling the use of velocity interferometry to continuously measure the shock velocity. This technique overlaps with the range of pressures accessible with LiF windows and extends the region where wave profile measurements are possible to pressures in excess of 2000 GPa. Lastly, we show through simulated data that the technique accurately reproduces the interface velocity within 20% of the initial state, and that the Lagrangian technique represents a significant improvement over a simple linear approximation.« less

  2. Lagrangian technique to calculate window interface velocity from shock velocity measurements: Application for quartz windows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCoy, Chad A.; Knudson, Marcus D.

    Measurement of the window interface velocity is a common technique for investigating the dynamic response materials at high strain rates. However, these measurements are limited in pressure to the range where the window remains transparent. The most common window material for this application is lithium fluoride, which under single shock compression becomes opaque at ~200 GPa. To date, no other window material has been identified for use at higher pressures. Here, we present a Lagrangian technique to calculate the interface velocity from a continuously measured shock velocity, with application to quartz. The quartz shock front becomes reflective upon melt, atmore » ~100 GPa, enabling the use of velocity interferometry to continuously measure the shock velocity. This technique overlaps with the range of pressures accessible with LiF windows and extends the region where wave profile measurements are possible to pressures in excess of 2000 GPa. Lastly, we show through simulated data that the technique accurately reproduces the interface velocity within 20% of the initial state, and that the Lagrangian technique represents a significant improvement over a simple linear approximation.« less

  3. Lobster eye as a collector for water window microscopy

    NASA Astrophysics Data System (ADS)

    Pina, L.; Maršíková, V.; Inneman, A.; Nawaz, M. F.; Jančárek, A.; Havlíková, R.

    2017-08-01

    Imaging in EUV, SXR and XR spectral bands of radiation is of increasing interest. Material science, biology and hot plasma are examples of relevant fast developing areas. Applications include spectroscopy, astrophysics, Soft X-ray Ray metrology, Water Window microscopy, radiography and tomography. Especially Water Window imaging has still not fully recognized potential in biology and medicine microscopy applications. Theoretical study and design of Lobster Eye (LE) optics as a collector for water window (WW) microscopy and comparison with a similar size ellipsoidal mirror condensor are presented.

  4. Application of ZigBee sensor network to data acquisition and monitoring

    NASA Astrophysics Data System (ADS)

    Terada, Mitsugu

    2009-01-01

    A ZigBee sensor network for data acquisition and monitoring is presented in this paper. It is configured using a commercially available ZigBee solution. A ZigBee module is connected via a USB interface to a Microsoft Windows PC, which works as a base station in the sensor network. Data collected by remote devices are sent to the base station PC, which is set as a data sink. Each remote device is built of a commercially available ZigBee module product and a sensor. The sensor is a thermocouple connected to a cold junction compensator amplifier. The signal from the amplifier is input to an AD converter port on the ZigBee module. Temperature data are transmitted according to the ZigBee protocol from the remote device to the data sink PC. The data sampling rate is one sampling per second; the highest possible rate is four samplings per second. The data are recorded in the hexadecimal number format by device control software, and the data file is stored in text format on the data sink PC. Time-dependent data changes can be monitored using the macro function of spreadsheet software. The system is considered a useful tool in the field of education, based on the results of trial use for measurement in an undergraduate laboratory class at a university.

  5. CDC Vital Signs: Adult Smoking among People with Mental Illness

    MedlinePlus

    ... PDF file Microsoft PowerPoint file Microsoft Word file Microsoft Excel ... National Center for Chronic Disease Prevention and Health Promotion, Office on Smoking and Health Page maintained by: Office ...

  6. Photos of MRSA Infections

    MedlinePlus

    ... and Team Healthcare Providers Prevention Information and Advice Posters for the Athletic Community General MRSA Information and ... site? Adobe PDF file Microsoft PowerPoint file Microsoft Word file Microsoft Excel file Audio/Video file Apple ...

  7. A general method to determine sampling windows for nonlinear mixed effects models with an application to population pharmacokinetic studies.

    PubMed

    Foo, Lee Kien; McGree, James; Duffull, Stephen

    2012-01-01

    Optimal design methods have been proposed to determine the best sampling times when sparse blood sampling is required in clinical pharmacokinetic studies. However, the optimal blood sampling time points may not be feasible in clinical practice. Sampling windows, a time interval for blood sample collection, have been proposed to provide flexibility in blood sampling times while preserving efficient parameter estimation. Because of the complexity of the population pharmacokinetic models, which are generally nonlinear mixed effects models, there is no analytical solution available to determine sampling windows. We propose a method for determination of sampling windows based on MCMC sampling techniques. The proposed method attains a stationary distribution rapidly and provides time-sensitive windows around the optimal design points. The proposed method is applicable to determine sampling windows for any nonlinear mixed effects model although our work focuses on an application to population pharmacokinetic models. Copyright © 2012 John Wiley & Sons, Ltd.

  8. Conducting Automated Test Assembly Using the Premium Solver Platform Version 7.0 with Microsoft Excel and the Large-Scale LP/QP Solver Engine Add-In

    ERIC Educational Resources Information Center

    Cor, Ken; Alves, Cecilia; Gierl, Mark J.

    2008-01-01

    This review describes and evaluates a software add-in created by Frontline Systems, Inc., that can be used with Microsoft Excel 2007 to solve large, complex test assembly problems. The combination of Microsoft Excel 2007 with the Frontline Systems Premium Solver Platform is significant because Microsoft Excel is the most commonly used spreadsheet…

  9. Windows Instant Messaging App Forensics: Facebook and Skype as Case Studies

    PubMed Central

    Yang, Teing Yee; Dehghantanha, Ali; Choo, Kim-Kwang Raymond; Muda, Zaiton

    2016-01-01

    Instant messaging (IM) has changed the way people communicate with each other. However, the interactive and instant nature of these applications (apps) made them an attractive choice for malicious cyber activities such as phishing. The forensic examination of IM apps for modern Windows 8.1 (or later) has been largely unexplored, as the platform is relatively new. In this paper, we seek to determine the data remnants from the use of two popular Windows Store application software for instant messaging, namely Facebook and Skype on a Windows 8.1 client machine. This research contributes to an in-depth understanding of the types of terrestrial artefacts that are likely to remain after the use of instant messaging services and application software on a contemporary Windows operating system. Potential artefacts detected during the research include data relating to the installation or uninstallation of the instant messaging application software, log-in and log-off information, contact lists, conversations, and transferred files. PMID:26982207

  10. Windows Instant Messaging App Forensics: Facebook and Skype as Case Studies.

    PubMed

    Yang, Teing Yee; Dehghantanha, Ali; Choo, Kim-Kwang Raymond; Muda, Zaiton

    2016-01-01

    Instant messaging (IM) has changed the way people communicate with each other. However, the interactive and instant nature of these applications (apps) made them an attractive choice for malicious cyber activities such as phishing. The forensic examination of IM apps for modern Windows 8.1 (or later) has been largely unexplored, as the platform is relatively new. In this paper, we seek to determine the data remnants from the use of two popular Windows Store application software for instant messaging, namely Facebook and Skype on a Windows 8.1 client machine. This research contributes to an in-depth understanding of the types of terrestrial artefacts that are likely to remain after the use of instant messaging services and application software on a contemporary Windows operating system. Potential artefacts detected during the research include data relating to the installation or uninstallation of the instant messaging application software, log-in and log-off information, contact lists, conversations, and transferred files.

  11. Putting the School Interoperability Framework to the Test

    ERIC Educational Resources Information Center

    Mercurius, Neil; Burton, Glenn; Hopkins, Bill; Larsen, Hans

    2004-01-01

    The Jurupa Unified School District in Southern California recently partnered with Microsoft, Dell and the Zone Integration Group for the implementation of a School Interoperability Framework (SIF) database repository model throughout the district (Magner 2002). A two-week project--the Integrated District Education Applications System, better known…

  12. Designing an eMap to Teach Multimedia Applications Online

    ERIC Educational Resources Information Center

    Ruffini, Michael F.

    2004-01-01

    Teachers and students use multimedia software to create interactive presentations and content projects. Popular multimedia programs include: Microsoft's PowerPoint[R], Knowledge Adventure's HyperStudio[R], and Macromedia's Director MX 2004[R]. Creating multimedia projects engage students in active learning and thinking as they complete projects…

  13. Students Computer Literacy: Perception versus Reality

    ERIC Educational Resources Information Center

    Wilkinson, Kelly

    2006-01-01

    Students believe that they are computer literate. When asked, students perceive themselves as skilled in a variety of computer applications. This research compares students' perceptions with their reality. Students did not perform well on pretests of Microsoft Office, but improved their posttests scores with instruction. The study also examined…

  14. Section 508 Electronic Information Accessibility Requirements for Software Development

    NASA Technical Reports Server (NTRS)

    Ellis, Rebecca

    2014-01-01

    Section 508 Subpart B 1194.21 outlines requirements for operating system and software development in order to create a product that is accessible to users with various disabilities. This portion of Section 508 contains a variety of standards to enable those using assistive technology and with visual, hearing, cognitive and motor difficulties to access all information provided in software. The focus on requirements was limited to the Microsoft Windows® operating system as it is the predominant operating system used at this center. Compliance with this portion of the requirements can be obtained by integrating the requirements into the software development cycle early and by remediating issues in legacy software if possible. There are certain circumstances with software that may arise necessitating an exemption from these requirements, such as design or engineering software using dynamically changing graphics or numbers to convey information. These exceptions can be discussed with the Section 508 Coordinator and another method of accommodation used.

  15. MetaQuant: a tool for the automatic quantification of GC/MS-based metabolome data.

    PubMed

    Bunk, Boyke; Kucklick, Martin; Jonas, Rochus; Münch, Richard; Schobert, Max; Jahn, Dieter; Hiller, Karsten

    2006-12-01

    MetaQuant is a Java-based program for the automatic and accurate quantification of GC/MS-based metabolome data. In contrast to other programs MetaQuant is able to quantify hundreds of substances simultaneously with minimal manual intervention. The integration of a self-acting calibration function allows the parallel and fast calibration for several metabolites simultaneously. Finally, MetaQuant is able to import GC/MS data in the common NetCDF format and to export the results of the quantification into Systems Biology Markup Language (SBML), Comma Separated Values (CSV) or Microsoft Excel (XLS) format. MetaQuant is written in Java and is available under an open source license. Precompiled packages for the installation on Windows or Linux operating systems are freely available for download. The source code as well as the installation packages are available at http://bioinformatics.org/metaquant

  16. Surgical simulation software for insertion of pedicle screws.

    PubMed

    Eftekhar, Behzad; Ghodsi, Mohammad; Ketabchi, Ebrahim; Rasaee, Saman

    2002-01-01

    As the first step toward finding noninvasive alternatives to the traditional methods of surgical training, we have developed a small, stand-alone computer program that simulates insertion of pedicle screws in different spinal vertebrae (T10-L5). We used Delphi 5.0 and DirectX 7.0 extension for Microsoft Windows. This is a stand-alone and portable program. The program can run on most personal computers. It provides the trainee with visual feedback during practice of the technique. At present, it uses predefined three-dimensional images of the vertebrae, but we are attempting to adapt the program to three-dimensional objects based on real computed tomographic scans of the patients. The program can be downloaded at no cost from the web site: www.tums.ac.ir/downloads As a preliminary work, it requires further development, particularly toward better visual, auditory, and even proprioceptive feedback and use of the individual patient's data.

  17. Using Cross-Sectional Imaging to Convey Organ Relationships: An Integrated Learning Environment for Students of Gross Anatomy

    PubMed Central

    Forman, Bruce H.; Eccles, Randy; Piggins, Judith; Raila, Wayne; Estey, Greg; Barnett, G. Octo

    1990-01-01

    We have developed a visually oriented, computer-controlled learning environment designed for use by students of gross anatomy. The goals of this module are to reinforce the concepts of organ relationships and topography by using computed axial tomographic (CAT) images accessed from a videodisc integrated with color graphics and to introduce students to cross-sectional radiographic anatomy. We chose to build the program around CAT scan images because they not only provide excellent structural detail but also offer an anatomic orientation (transverse) that complements that used in the dissection laboratory (basically a layer-by-layer, anterior-to-posterior, or coronal approach). Our system, built using a Microsoft Windows-386 based authoring environment which we designed and implemented, integrates text, video images, and graphics into a single screen display. The program allows both user browsing of information, facilitated by hypertext links, and didactic sessions including mini-quizzes for self-assessment.

  18. Development of yarn breakage detection software system based on machine vision

    NASA Astrophysics Data System (ADS)

    Wang, Wenyuan; Zhou, Ping; Lin, Xiangyu

    2017-10-01

    For questions spinning mills and yarn breakage cannot be detected in a timely manner, and save the cost of textile enterprises. This paper presents a software system based on computer vision for real-time detection of yarn breakage. The system and Windows8.1 system Tablet PC, cloud server to complete the yarn breakage detection and management. Running on the Tablet PC software system is designed to collect yarn and location information for analysis and processing. And will be processed after the information through the Wi-Fi and http protocol sent to the cloud server to store in the Microsoft SQL2008 database. In order to follow up on the yarn break information query and management. Finally sent to the local display on time display, and remind the operator to deal with broken yarn. The experimental results show that the system of missed test rate not more than 5%o, and no error detection.

  19. Chemicalome and metabolome profiling of polymethoxylated flavonoids in Citri Reticulatae Pericarpium based on an integrated strategy combining background subtraction and modified mass defect filter in a Microsoft Excel Platform.

    PubMed

    Zeng, Su-Ling; Duan, Li; Chen, Bai-Zhong; Li, Ping; Liu, E-Hu

    2017-07-28

    Detection of metabolites in complex biological matrixes is a great challenge because of the background noise and endogenous components. Herein, we proposed an integrated strategy that combined background subtraction program and modified mass defect filter (MMDF) data mining in a Microsoft Excel platform for chemicalome and metabolome profiling of the polymethoxylated flavonoids (PMFs) in Citri Reticulatae Pericarpium (CRP). The exogenously-sourced ions were firstly filtered out by the developed Visual Basic for Applications (VBA) program incorporated in the Microsoft Office. The novel MMDF strategy was proposed for detecting both target and untarget constituents and metabolites based on narrow, well-defined mass defect ranges. The approach was validated to be powerful, and potentially useful for the metabolite identification of both single compound and homologous compound mixture. We successfully identified 30 and 31 metabolites from rat biosamples after oral administration of nobiletin and tangeretin, respectively. A total of 56 PMFs compounds were chemically characterized and 125 metabolites were captured. This work demonstrated the feasibility of the integrated approach for reliable characterization of the constituents and metabolites in herbal medicines. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. High-temperature, high-pressure optical port for rocket engine applications

    NASA Technical Reports Server (NTRS)

    Delcher, Ray; Nemeth, ED; Powers, W. T.

    1993-01-01

    This paper discusses the design, fabrication, and test of a window assembly for instrumentation of liquid-fueled rocket engine hot gas systems. The window was designed to allow optical measurements of hot gas in the SSME fuel preburner and appears to be the first window designed for application in a rocket engine hot gas system. Such a window could allow the use of a number of remote optical measurement technologies including: Raman temperature and species concentration measurement, Raleigh temperature measurements, flame emission monitoring, flow mapping, laser-induced florescence, and hardware imaging during engine operation. The window assembly has been successfully tested to 8,000 psi at 1000 F and over 11,000 psi at room temperature. A computer stress analysis shows the window will withstand high temperature and cryogenic thermal shock.

  1. STEREO: a program on a PC-Windows 95 platform for recording and evaluating quantitative stereologic investigations of multistage hepatocarcinogenesis in rodents.

    PubMed

    Xu, Y H; Dragan, Y P; Campbell, H A; Pitot, H C

    1998-04-01

    The most common organ site of neoplasms induced by carcinogenic chemicals in the rodent bioassay is the liver. The development of cancer in rodent liver is a multistage process involving sequentially the stages of initiation, promotion, and progression. During the stages of promotion and progression, numerous lesions termed altered hepatic foci (AHF) develop. STEREO was developed for the purpose of efficient and accurate quantitation of AHF and related lesions in experimental and test rodents. The system utilized is equipped with a microcomputer (IBM-compatible PC running Windows 95) and a Summagraphics MICROGRID or SummaSketch tablet digitizer. The program records information from digitization of single or serial sections obtained randomly from rat liver tissue. With this information and the methods of quantitative stereology, both the number and volume percentage fraction of AHF in liver are calculated in three dimensions. The recorded data files can be printed graphically or in the format of tabular numerical data. The results of stereologic calculations are stored on floppy disks and can be sorted into different categories and analyzed or displayed with the use of statistics and graphic functions built into the overall program. Results may also be exported into Microsoft Excel for use at a later time. Any IBM-compatible PC capable of utilizing Windows 95 and MS Office can be used with STEREO, which offers inexpensive, easily operated software to obtain three-dimensional information from sections of two dimensions for the identification and relative potency of initiators, promoters, and progressors, and for the establishment of information potentially useful in developing estimations of risk for human cancer.

  2. Software components for medical image visualization and surgical planning

    NASA Astrophysics Data System (ADS)

    Starreveld, Yves P.; Gobbi, David G.; Finnis, Kirk; Peters, Terence M.

    2001-05-01

    Purpose: The development of new applications in medical image visualization and surgical planning requires the completion of many common tasks such as image reading and re-sampling, segmentation, volume rendering, and surface display. Intra-operative use requires an interface to a tracking system and image registration, and the application requires basic, easy to understand user interface components. Rapid changes in computer and end-application hardware, as well as in operating systems and network environments make it desirable to have a hardware and operating system as an independent collection of reusable software components that can be assembled rapidly to prototype new applications. Methods: Using the OpenGL based Visualization Toolkit as a base, we have developed a set of components that implement the above mentioned tasks. The components are written in both C++ and Python, but all are accessible from Python, a byte compiled scripting language. The components have been used on the Red Hat Linux, Silicon Graphics Iris, Microsoft Windows, and Apple OS X platforms. Rigorous object-oriented software design methods have been applied to ensure hardware independence and a standard application programming interface (API). There are components to acquire, display, and register images from MRI, MRA, CT, Computed Rotational Angiography (CRA), Digital Subtraction Angiography (DSA), 2D and 3D ultrasound, video and physiological recordings. Interfaces to various tracking systems for intra-operative use have also been implemented. Results: The described components have been implemented and tested. To date they have been used to create image manipulation and viewing tools, a deep brain functional atlas, a 3D ultrasound acquisition and display platform, a prototype minimally invasive robotic coronary artery bypass graft planning system, a tracked neuro-endoscope guidance system and a frame-based stereotaxy neurosurgery planning tool. The frame-based stereotaxy module has been licensed and certified for use in a commercial image guidance system. Conclusions: It is feasible to encapsulate image manipulation and surgical guidance tasks in individual, reusable software modules. These modules allow for faster development of new applications. The strict application of object oriented software design methods allows individual components of such a system to make the transition from the research environment to a commercial one.

  3. Enhancing Instruction through Constructivism, Cooperative Learning, and Cloud Computing

    ERIC Educational Resources Information Center

    Denton, David W.

    2012-01-01

    Cloud computing technologies, such as Google Docs and Microsoft Office Live, have the potential to enhance instructional methods predicated on constructivism and cooperative learning. Cloud-based application features like file sharing and online publishing are prompting departments of education across the nation to adopt these technologies.…

  4. The Effects of Elaboration on Self-Learning Procedures from Text.

    ERIC Educational Resources Information Center

    Yang, Fu-mei

    This study investigated the effects of augmenting and deleting elaborations in an existing self-instructional text for a micro-computer database application, "Microsoft Works User's Manual." A total of 60 undergraduate students were randomly assigned to the original, elaborated, or unelaborated text versions. The elaborated version…

  5. Open Scenario Study, Phase II Report: Assessment and Development of Approaches for Satisfying Unclassified Scenario Needs

    DTIC Science & Technology

    2010-01-01

    interface, another providing the application logic (a program used to manipulate the data), and a server running Microsoft SQL Server or Oracle RDBMS... Oracle ) • Mysql (Open Source) • Other What application server software will be needed? • Application Server • CGI PHP/Perl (Open Source...are used throughout DoD and serve a variety of functions. While DoD has a codified and institutionalized process for the development of a common set

  6. Continuation of research into software for space operations support: Conversion of the display manager to X Windows/Motif, volume 2

    NASA Technical Reports Server (NTRS)

    Collier, Mark D.; Killough, Ronnie; Martin, Nancy L.

    1990-01-01

    NASA is currently using a set of applications called the Display Builder and Display Manager. They run on Concurrent systems and heavily depend on the Graphic Kernel System (GKS). At this time however, these two applications would more appropriately be developed in X Windows, in which a low X is used for all actual text and graphics display and a standard widget set (such as Motif) is used for the user interface. Use of the X Windows will increase performance, improve the user interface, enhance portability, and improve reliability. Prototype of X Window/Motif based Display Manager provides the following advantages over a GKS based application: improved performance by using a low level X Windows, display of graphic and text will be more efficient; improved user interface by using Motif; Improved portability by operating on both Concurrent and Sun workstations; and Improved reliability.

  7. A Review on Technical and Clinical Impact of Microsoft Kinect on Physical Therapy and Rehabilitation

    PubMed Central

    Mousavi Hondori, Hossein; Khademi, Maryam

    2014-01-01

    This paper reviews technical and clinical impact of the Microsoft Kinect in physical therapy and rehabilitation. It covers the studies on patients with neurological disorders including stroke, Parkinson's, cerebral palsy, and MS as well as the elderly patients. Search results in Pubmed and Google scholar reveal increasing interest in using Kinect in medical application. Relevant papers are reviewed and divided into three groups: (1) papers which evaluated Kinect's accuracy and reliability, (2) papers which used Kinect for a rehabilitation system and provided clinical evaluation involving patients, and (3) papers which proposed a Kinect-based system for rehabilitation but fell short of providing clinical validation. At last, to serve as technical comparison to help future rehabilitation design other sensors similar to Kinect are reviewed. PMID:27006935

  8. A Review on Technical and Clinical Impact of Microsoft Kinect on Physical Therapy and Rehabilitation.

    PubMed

    Mousavi Hondori, Hossein; Khademi, Maryam

    2014-01-01

    This paper reviews technical and clinical impact of the Microsoft Kinect in physical therapy and rehabilitation. It covers the studies on patients with neurological disorders including stroke, Parkinson's, cerebral palsy, and MS as well as the elderly patients. Search results in Pubmed and Google scholar reveal increasing interest in using Kinect in medical application. Relevant papers are reviewed and divided into three groups: (1) papers which evaluated Kinect's accuracy and reliability, (2) papers which used Kinect for a rehabilitation system and provided clinical evaluation involving patients, and (3) papers which proposed a Kinect-based system for rehabilitation but fell short of providing clinical validation. At last, to serve as technical comparison to help future rehabilitation design other sensors similar to Kinect are reviewed.

  9. 78 FR 68839 - Tribal Mobility Fund Phase I Auction Rescheduled for February 25, 2014; Notice of Changes to...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-15

    ...) announce the rescheduling of Auction 902 and revise the dates and deadlines for the filing window for short...-auction deadlines for Auction 902. 2. The Auction 902 short-form application filing window opened at 12... short-form application (FCC Form 180) filing window will reopen on November 18, 2013, at 12:00 noon ET...

  10. A powerful and efficient set test for genetic markers that handles confounders

    PubMed Central

    Listgarten, Jennifer; Lippert, Christoph; Kang, Eun Yong; Xiang, Jing; Kadie, Carl M.; Heckerman, David

    2013-01-01

    Motivation: Approaches for testing sets of variants, such as a set of rare or common variants within a gene or pathway, for association with complex traits are important. In particular, set tests allow for aggregation of weak signal within a set, can capture interplay among variants and reduce the burden of multiple hypothesis testing. Until now, these approaches did not address confounding by family relatedness and population structure, a problem that is becoming more important as larger datasets are used to increase power. Results: We introduce a new approach for set tests that handles confounders. Our model is based on the linear mixed model and uses two random effects—one to capture the set association signal and one to capture confounders. We also introduce a computational speedup for two random-effects models that makes this approach feasible even for extremely large cohorts. Using this model with both the likelihood ratio test and score test, we find that the former yields more power while controlling type I error. Application of our approach to richly structured Genetic Analysis Workshop 14 data demonstrates that our method successfully corrects for population structure and family relatedness, whereas application of our method to a 15 000 individual Crohn’s disease case–control cohort demonstrates that it additionally recovers genes not recoverable by univariate analysis. Availability: A Python-based library implementing our approach is available at http://mscompbio.codeplex.com. Contact: jennl@microsoft.com or lippert@microsoft.com or heckerma@microsoft.com Supplementary information: Supplementary data are available at Bioinformatics online. PMID:23599503

  11. Xyce Parallel Electronic Simulator Reference Guide Version 6.6.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keiter, Eric R.; Aadithya, Karthik Venkatraman; Mei, Ting

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users' Guide [1] . The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce . This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users' Guide [1] . The information herein is subject to change without notice. Copyright c 2002-2016 Sandia Corporation. All rights reserved. Acknowledgements The BSIM Group at the University ofmore » California, Berkeley developed the BSIM3, BSIM4, BSIM6, BSIM-CMG and BSIM-SOI models. The BSIM3 is Copyright c 1999, Regents of the University of California. The BSIM4 is Copyright c 2006, Regents of the University of California. The BSIM6 is Copyright c 2015, Regents of the University of California. The BSIM-CMG is Copyright c 2012 and 2016, Regents of the University of California. The BSIM-SOI is Copyright c 1990, Regents of the University of California. All rights reserved. The Mextram model has been developed by NXP Semiconductors until 2007, Delft University of Technology from 2007 to 2014, and Auburn University since April 2015. Copyrights c of Mextram are with Delft University of Technology, NXP Semiconductors and Auburn University. The MIT VS Model Research Group developed the MIT Virtual Source (MVS) model. Copyright c 2013 Massachusetts Institute of Technology (MIT). The EKV3 MOSFET model was developed by the EKV Team of the Electronics Laboratory-TUC of the Technical University of Crete. Trademarks Xyce TM Electronic Simulator and Xyce TM are trademarks of Sandia Corporation. Orcad, Orcad Capture, PSpice and Probe are registered trademarks of Cadence Design Systems, Inc. Microsoft, Windows and Windows 7 are registered trademarks of Microsoft Corporation. Medici, DaVinci and Taurus are registered trademarks of Synopsys Corporation. Amtec and TecPlot are trademarks of Amtec Engineering, Inc. All other trademarks are property of their respective owners. Contacts World Wide Web http://xyce.sandia.gov https://info.sandia.gov/xyce (Sandia only) Email xyce@sandia.gov (outside Sandia) xyce-sandia@sandia.gov (Sandia only) Bug Reports (Sandia only) http://joseki-vm.sandia.gov/bugzilla http://morannon.sandia.gov/bugzilla« less

  12. FastStats: Kidney Disease

    MedlinePlus

    ... PDF file Microsoft PowerPoint file Microsoft Word file Microsoft Excel file Audio/Video file Apple Quicktime file RealPlayer file Text file Zip Archive file SAS file ePub file RIS file Page last reviewed: February 18, 2013 Page last updated: March 30, 2017 Content source: ...

  13. Constructing complex graphics applications with CLIPS and the X window system

    NASA Technical Reports Server (NTRS)

    Faul, Ben M.

    1990-01-01

    This article will demonstrate how the artificial intelligence concepts in CLIPS used to solve problems encountered in the design and implementation of graphics applications within the UNIX-X Window System environment. The design of an extended version of CLIPS, called XCLIPS, is presented to show how the X Windows System graphics can be incorporated without losing DOS compatibility. Using XCLIPS, a sample scientific application is built that applies solving capabilities of both two and three dimensional graphics presentations in conjunction with the standard CLIPS features.

  14. Scabies: Workplace Frequently Asked Questions (FAQs)

    MedlinePlus

    ... PDF file Microsoft PowerPoint file Microsoft Word file Microsoft Excel file Audio/Video file Apple Quicktime file RealPlayer file Text file Zip Archive file SAS file ePub file RIS file Page last reviewed: July 19, 2013 Page last updated: July 19, 2013 Content source: ...

  15. ImmunoRatio: a publicly available web application for quantitative image analysis of estrogen receptor (ER), progesterone receptor (PR), and Ki-67

    PubMed Central

    2010-01-01

    Introduction Accurate assessment of estrogen receptor (ER), progesterone receptor (PR), and Ki-67 is essential in the histopathologic diagnostics of breast cancer. Commercially available image analysis systems are usually bundled with dedicated analysis hardware and, to our knowledge, no easily installable, free software for immunostained slide scoring has been described. In this study, we describe a free, Internet-based web application for quantitative image analysis of ER, PR, and Ki-67 immunohistochemistry in breast cancer tissue sections. Methods The application, named ImmunoRatio, calculates the percentage of positively stained nuclear area (labeling index) by using a color deconvolution algorithm for separating the staining components (diaminobenzidine and hematoxylin) and adaptive thresholding for nuclear area segmentation. ImmunoRatio was calibrated using cell counts defined visually as the gold standard (training set, n = 50). Validation was done using a separate set of 50 ER, PR, and Ki-67 stained slides (test set, n = 50). In addition, Ki-67 labeling indexes determined by ImmunoRatio were studied for their prognostic value in a retrospective cohort of 123 breast cancer patients. Results The labeling indexes by calibrated ImmunoRatio analyses correlated well with those defined visually in the test set (correlation coefficient r = 0.98). Using the median Ki-67 labeling index (20%) as a cutoff, a hazard ratio of 2.2 was obtained in the survival analysis (n = 123, P = 0.01). ImmunoRatio was shown to adapt to various staining protocols, microscope setups, digital camera models, and image acquisition settings. The application can be used directly with web browsers running on modern operating systems (e.g., Microsoft Windows, Linux distributions, and Mac OS). No software downloads or installations are required. ImmunoRatio is open source software, and the web application is publicly accessible on our website. Conclusions We anticipate that free web applications, such as ImmunoRatio, will make the quantitative image analysis of ER, PR, and Ki-67 easy and straightforward in the diagnostic assessment of breast cancer specimens. PMID:20663194

  16. ImmunoRatio: a publicly available web application for quantitative image analysis of estrogen receptor (ER), progesterone receptor (PR), and Ki-67.

    PubMed

    Tuominen, Vilppu J; Ruotoistenmäki, Sanna; Viitanen, Arttu; Jumppanen, Mervi; Isola, Jorma

    2010-01-01

    Accurate assessment of estrogen receptor (ER), progesterone receptor (PR), and Ki-67 is essential in the histopathologic diagnostics of breast cancer. Commercially available image analysis systems are usually bundled with dedicated analysis hardware and, to our knowledge, no easily installable, free software for immunostained slide scoring has been described. In this study, we describe a free, Internet-based web application for quantitative image analysis of ER, PR, and Ki-67 immunohistochemistry in breast cancer tissue sections. The application, named ImmunoRatio, calculates the percentage of positively stained nuclear area (labeling index) by using a color deconvolution algorithm for separating the staining components (diaminobenzidine and hematoxylin) and adaptive thresholding for nuclear area segmentation. ImmunoRatio was calibrated using cell counts defined visually as the gold standard (training set, n = 50). Validation was done using a separate set of 50 ER, PR, and Ki-67 stained slides (test set, n = 50). In addition, Ki-67 labeling indexes determined by ImmunoRatio were studied for their prognostic value in a retrospective cohort of 123 breast cancer patients. The labeling indexes by calibrated ImmunoRatio analyses correlated well with those defined visually in the test set (correlation coefficient r = 0.98). Using the median Ki-67 labeling index (20%) as a cutoff, a hazard ratio of 2.2 was obtained in the survival analysis (n = 123, P = 0.01). ImmunoRatio was shown to adapt to various staining protocols, microscope setups, digital camera models, and image acquisition settings. The application can be used directly with web browsers running on modern operating systems (e.g., Microsoft Windows, Linux distributions, and Mac OS). No software downloads or installations are required. ImmunoRatio is open source software, and the web application is publicly accessible on our website. We anticipate that free web applications, such as ImmunoRatio, will make the quantitative image analysis of ER, PR, and Ki-67 easy and straightforward in the diagnostic assessment of breast cancer specimens.

  17. 24 CFR 200.955 - Supplementary specific requirements under the HUD building product standard and certification...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... under the HUD building product standard and certification program for fenestration products (windows and... fenestration products (windows and doors). (a) Applicable standards. (1) All windows and doors shall be... Windows and Glass Doors. (2) This standard has been approved by the Director of the Federal Register for...

  18. Closed Loop Experiment Manager (CLEM)-An Open and Inexpensive Solution for Multichannel Electrophysiological Recordings and Closed Loop Experiments.

    PubMed

    Hazan, Hananel; Ziv, Noam E

    2017-01-01

    There is growing need for multichannel electrophysiological systems that record from and interact with neuronal systems in near real-time. Such systems are needed, for example, for closed loop, multichannel electrophysiological/optogenetic experimentation in vivo and in a variety of other neuronal preparations, or for developing and testing neuro-prosthetic devices, to name a few. Furthermore, there is a need for such systems to be inexpensive, reliable, user friendly, easy to set-up, open and expandable, and possess long life cycles in face of rapidly changing computing environments. Finally, they should provide powerful, yet reasonably easy to implement facilities for developing closed-loop protocols for interacting with neuronal systems. Here, we survey commercial and open source systems that address these needs to varying degrees. We then present our own solution, which we refer to as Closed Loop Experiments Manager (CLEM). CLEM is an open source, soft real-time, Microsoft Windows desktop application that is based on a single generic personal computer (PC) and an inexpensive, general-purpose data acquisition board. CLEM provides a fully functional, user-friendly graphical interface, possesses facilities for recording, presenting and logging electrophysiological data from up to 64 analog channels, and facilities for controlling external devices, such as stimulators, through digital and analog interfaces. Importantly, it includes facilities for running closed-loop protocols written in any programming language that can generate dynamic link libraries (DLLs). We describe the application, its architecture and facilities. We then demonstrate, using networks of cortical neurons growing on multielectrode arrays (MEA) that despite its reliance on generic hardware, its performance is appropriate for flexible, closed-loop experimentation at the neuronal network level.

  19. Trace element reference values in tissues from inhabitants of the EU. XII. Development of BioReVa program for statistical treatment.

    PubMed

    Iversen, B S; Sabbioni, E; Fortaner, S; Pietra, R; Nicolotti, A

    2003-01-20

    Statistical data treatment is a key point in the assessment of trace element reference values being the conclusive stage of a comprehensive and organized evaluation process of metal concentration in human body fluids. The EURO TERVIHT project (Trace Elements Reference Values in Human Tissues) was started for evaluating, checking and suggesting harmonized procedures for the establishment of trace element reference intervals in body fluids and tissues. Unfortunately, different statistical approaches are being used in this research field making data comparison difficult and in some cases impossible. Although international organizations such as International Federation of Clinical Chemistry (IFCC) or International Union of Pure and Applied Chemistry (IUPAC) have issued recommended guidelines for reference values assessment, including the statistical data treatment, a unique format and a standardized data layout is still missing. The aim of the present study is to present a software (BioReVa) running under Microsoft Windows platform suitable for calculating the reference intervals of trace elements in body matrices. The main scope for creating an ease-of-use application was to control the data distribution, to establish the reference intervals according to the accepted recommendation, on the base of the simple statistic, to get a standard presentation of experimental data and to have an application to which further need could be integrated in future. BioReVa calculates the IFCC reference intervals as well as the coverage intervals recommended by IUPAC as a supplement to the IFCC intervals. Examples of reference values and reference intervals calculated with BioReVa software concern Pb and Se in blood; Cd, In and Cr in urine, Hg and Mo in hair of different general European populations. University of Michigan

  20. Closed Loop Experiment Manager (CLEM)—An Open and Inexpensive Solution for Multichannel Electrophysiological Recordings and Closed Loop Experiments

    PubMed Central

    Hazan, Hananel; Ziv, Noam E.

    2017-01-01

    There is growing need for multichannel electrophysiological systems that record from and interact with neuronal systems in near real-time. Such systems are needed, for example, for closed loop, multichannel electrophysiological/optogenetic experimentation in vivo and in a variety of other neuronal preparations, or for developing and testing neuro-prosthetic devices, to name a few. Furthermore, there is a need for such systems to be inexpensive, reliable, user friendly, easy to set-up, open and expandable, and possess long life cycles in face of rapidly changing computing environments. Finally, they should provide powerful, yet reasonably easy to implement facilities for developing closed-loop protocols for interacting with neuronal systems. Here, we survey commercial and open source systems that address these needs to varying degrees. We then present our own solution, which we refer to as Closed Loop Experiments Manager (CLEM). CLEM is an open source, soft real-time, Microsoft Windows desktop application that is based on a single generic personal computer (PC) and an inexpensive, general-purpose data acquisition board. CLEM provides a fully functional, user-friendly graphical interface, possesses facilities for recording, presenting and logging electrophysiological data from up to 64 analog channels, and facilities for controlling external devices, such as stimulators, through digital and analog interfaces. Importantly, it includes facilities for running closed-loop protocols written in any programming language that can generate dynamic link libraries (DLLs). We describe the application, its architecture and facilities. We then demonstrate, using networks of cortical neurons growing on multielectrode arrays (MEA) that despite its reliance on generic hardware, its performance is appropriate for flexible, closed-loop experimentation at the neuronal network level. PMID:29093659

  1. Three-dimensional laser window formation for industrial application

    NASA Technical Reports Server (NTRS)

    Verhoff, Vincent G.; Kowalski, David

    1993-01-01

    The NASA Lewis Research Center has developed and implemented a unique process for forming flawless three-dimensional, compound-curvature laser windows to extreme accuracies. These windows represent an integral component of specialized nonintrusive laser data acquisition systems that are used in a variety of compressor and turbine research testing facilities. These windows are molded to the flow surface profile of turbine and compressor casings and are required to withstand extremely high pressures and temperatures. This method of glass formation could also be used to form compound-curvature mirrors that would require little polishing and for a variety of industrial applications, including research view ports for testing devices and view ports for factory machines with compound-curvature casings. Currently, sodium-alumino-silicate glass is recommended for three-dimensional laser windows because of its high strength due to chemical strengthening and its optical clarity. This paper discusses the main aspects of three-dimensional laser window formation. It focuses on the unique methodology and the peculiarities that are associated with the formation of these windows.

  2. Inclusion in the Microsoft Workforce

    ERIC Educational Resources Information Center

    Exceptional Parent, 2008

    2008-01-01

    Since 1975, Microsoft has been a worldwide leader in software, services, and solutions that help people and businesses realize their full potential. Loren Mikola, the Disability Inclusion Program Manager at Microsoft, ensures that this technology also reaches and includes the special needs population and, through the hiring of individuals with…

  3. FastStats: Chronic Liver Disease and Cirrhosis

    MedlinePlus

    ... PDF file Microsoft PowerPoint file Microsoft Word file Microsoft Excel file Audio/Video file Apple Quicktime file RealPlayer file Text file Zip Archive file SAS file ePub file RIS file Page last reviewed: May 30, 2013 Page last updated: October 6, 2016 Content source: ...

  4. Developing and Evaluating an Oral Skills Training Website Supported by Automatic Speech Recognition Technology

    ERIC Educational Resources Information Center

    Chen, Howard Hao-Jan

    2011-01-01

    Oral communication ability has become increasingly important to many EFL students. Several commercial software programs based on automatic speech recognition (ASR) technologies are available but their prices are not affordable for many students. This paper will demonstrate how the Microsoft Speech Application Software Development Kit (SASDK), a…

  5. Enhancing the Classroom Experience: Instructor Use of Tablets

    ERIC Educational Resources Information Center

    Cummings, Jeff; Hill, Stephen

    2015-01-01

    Instructors continually search for innovative approaches to interact with and engage students in the classroom. The tablet offers a potential innovation for this purpose. Tablet devices from Apple, Microsoft, and other hardware vendors have overcome many of the challenges of the past (e.g. cost and limited applications) to become useful tools for…

  6. 78 FR 49061 - Valuation of Federal Coal for Advance Royalty Purposes and Information Collection Applicable to...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-12

    ... use available information technology (for example: Spreadsheet programs, i.e., Microsoft Excel, web...) 231- 3221, or by email at [email protected] . SUPPLEMENTARY INFORMATION: I. Background A. Pre... part 1218, subpart I, titled ``Federal Coal Advance Royalty.'' B. The EPAct On August 8, 2005, the...

  7. Building Higher-Order Markov Chain Models with EXCEL

    ERIC Educational Resources Information Center

    Ching, Wai-Ki; Fung, Eric S.; Ng, Michael K.

    2004-01-01

    Categorical data sequences occur in many applications such as forecasting, data mining and bioinformatics. In this note, we present higher-order Markov chain models for modelling categorical data sequences with an efficient algorithm for solving the model parameters. The algorithm can be implemented easily in a Microsoft EXCEL worksheet. We give a…

  8. 77 FR 4891 - Technical Corrections to Commission Regulations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-01

    ... removes 18 CFR 4.34(b)(5)(iv) concerning new requests for water quality certification if an application to... material adverse impact on the water quality in the discharge from the project or proposed project. The... PDF and Microsoft Word format for viewing, printing, and/or downloading. To access this document in e...

  9. Gaussian-Type Orbitals versus Slater-Type Orbitals: A Comparison

    ERIC Educational Resources Information Center

    Magalha~es, Alexandre L.

    2014-01-01

    The advantages of Gaussian-type orbitals (GTO) over Slater-type orbitals (STO) in quantum chemistry calculations are clarified here by means of a holistic approach. The popular Microsoft Office Excel program was used to create an interactive application with which students are able to explore the features of GTO, including automatic calculations…

  10. Learning Technology Skills through Social Entrepreneurialism

    ERIC Educational Resources Information Center

    Pendleton, Jean

    2009-01-01

    When the author first arrived at Charleston Collegiate School, she was handed a college-level Microsoft business applications textbook and told she'd be teaching a one-semester ninth grade technology course. Since the course had never been taught before, she was given little more direction than: "Teach them Office and anything else you think they…

  11. Teaching Computer Skills to Beginners: What and How?

    ERIC Educational Resources Information Center

    Dunsworth, Qi; Martin, Florence; Igoe, Ann

    2004-01-01

    This report describes an evaluation of Computer Literacy, which is an undergraduate general studies course, offered by College of Education at a large southwestern university. The purpose of this course is to provide knowledge about computer and computing, and application skills in using Microsoft Office software. The course is coordinated by a…

  12. What Web 2.0 Can Teach Us about Learning

    ERIC Educational Resources Information Center

    Maloney, Edward J.

    2007-01-01

    The past 15 years have seen a significant increase in the use of technology in higher education. In fact, professors now find it difficult to imagine teaching without the Internet, course-management systems, Microsoft Office, e-mail, and other technological applications. Course-management systems allow faculty members to deliver materials to their…

  13. Environmental flow allocation and statistics calculator

    USGS Publications Warehouse

    Konrad, Christopher P.

    2011-01-01

    The Environmental Flow Allocation and Statistics Calculator (EFASC) is a computer program that calculates hydrologic statistics based on a time series of daily streamflow values. EFASC will calculate statistics for daily streamflow in an input file or will generate synthetic daily flow series from an input file based on rules for allocating and protecting streamflow and then calculate statistics for the synthetic time series. The program reads dates and daily streamflow values from input files. The program writes statistics out to a series of worksheets and text files. Multiple sites can be processed in series as one run. EFASC is written in MicrosoftRegistered Visual BasicCopyright for Applications and implemented as a macro in MicrosoftOffice Excel 2007Registered. EFASC is intended as a research tool for users familiar with computer programming. The code for EFASC is provided so that it can be modified for specific applications. All users should review how output statistics are calculated and recognize that the algorithms may not comply with conventions used to calculate streamflow statistics published by the U.S. Geological Survey.

  14. Do-It-Yourself: A Special Library's Approach to Creating Dynamic Web Pages Using Commercial Off-The-Shelf Applications

    NASA Technical Reports Server (NTRS)

    Steeman, Gerald; Connell, Christopher

    2000-01-01

    Many librarians may feel that dynamic Web pages are out of their reach, financially and technically. Yet we are reminded in library and Web design literature that static home pages are a thing of the past. This paper describes how librarians at the Institute for Defense Analyses (IDA) library developed a database-driven, dynamic intranet site using commercial off-the-shelf applications. Administrative issues include surveying a library users group for interest and needs evaluation; outlining metadata elements; and, committing resources from managing time to populate the database and training in Microsoft FrontPage and Web-to-database design. Technical issues covered include Microsoft Access database fundamentals, lessons learned in the Web-to-database process (including setting up Database Source Names (DSNs), redesigning queries to accommodate the Web interface, and understanding Access 97 query language vs. Standard Query Language (SQL)). This paper also offers tips on editing Active Server Pages (ASP) scripting to create desired results. A how-to annotated resource list closes out the paper.

  15. Application of Thinned-Skull Cranial Window to Mouse Cerebral Blood Flow Imaging Using Optical Microangiography

    PubMed Central

    Wang, Ruikang K.

    2014-01-01

    In vivo imaging of mouse brain vasculature typically requires applying skull window opening techniques: open-skull cranial window or thinned-skull cranial window. We report non-invasive 3D in vivo cerebral blood flow imaging of C57/BL mouse by the use of ultra-high sensitive optical microangiography (UHS-OMAG) and Doppler optical microangiography (DOMAG) techniques to evaluate two cranial window types based on their procedures and ability to visualize surface pial vessel dynamics. Application of the thinned-skull technique is found to be effective in achieving high quality images for pial vessels for short-term imaging, and has advantages over the open-skull technique in available imaging area, surgical efficiency, and cerebral environment preservation. In summary, thinned-skull cranial window serves as a promising tool in studying hemodynamics in pial microvasculature using OMAG or other OCT blood flow imaging modalities. PMID:25426632

  16. Progress Report--Microsoft Office 2003 Lynchburg College Tutorials

    ERIC Educational Resources Information Center

    Murray, Tom

    2004-01-01

    For the past several years Lynchburg College has developed Microsoft tutorials for use with academic classes and faculty, student and staff training. The tutorials are now used internationally. Last year Microsoft and Verizon sponsored a tutorial web site at http://www.officetutorials.com. This website recognizes ASCUE members for their wonderful…

  17. The quest to make accessibility a corporate article of faith at Microsoft: case study of corporate culture and human resource dimensions.

    PubMed

    Sandler, Leonard A; Blanck, Peter

    2005-01-01

    This case study examines efforts by Microsoft Corporation to enhance the diversity of its workforce and improve the accessibility and usability of its products and services for persons with disabilities. The research explores the relation among the Americans with Disabilities Act of 1990, corporate leadership, attitudes and behaviors towards individuals with disabilities, and dynamics that shape organizational culture at Microsoft. Implications for Microsoft, other employers, researchers, and the disability community are discussed. 2005 John Wiley & Sons, Ltd.

  18. Using a Hydrological Model to Determine Environmentally Safer Windows for Herbicide Application

    Treesearch

    J.L. Michael; M.C. Smith; W.G. Knisel; D.G. Neary; W.P. Fowler; D.J. Turton

    1996-01-01

    A modification of the GLEAMS model was used to determine application windows which would optimise efficacy and environmental safety for herbicide application to a forest site. Herbicide/soil partition coefficients were determined using soil samples collected from the study site for two herbicides (imazapyr, Koc=46, triclopyr ester, K

  19. 49 CFR 571.205(a) - Glazing equipment manufactured before September 1, 2006 and glazing materials used in vehicles...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... vehicle windows for driver visibility, and to minimize the possibility of occupants being thrown through the vehicle windows in collisions. S3. Application. This standard applies to glazing equipment...) [Reserved] (j) Windows and doors in motor homes, except for the windshield and windows to the immediate...

  20. PKSolver: An add-in program for pharmacokinetic and pharmacodynamic data analysis in Microsoft Excel.

    PubMed

    Zhang, Yong; Huo, Meirong; Zhou, Jianping; Xie, Shaofei

    2010-09-01

    This study presents PKSolver, a freely available menu-driven add-in program for Microsoft Excel written in Visual Basic for Applications (VBA), for solving basic problems in pharmacokinetic (PK) and pharmacodynamic (PD) data analysis. The program provides a range of modules for PK and PD analysis including noncompartmental analysis (NCA), compartmental analysis (CA), and pharmacodynamic modeling. Two special built-in modules, multiple absorption sites (MAS) and enterohepatic circulation (EHC), were developed for fitting the double-peak concentration-time profile based on the classical one-compartment model. In addition, twenty frequently used pharmacokinetic functions were encoded as a macro and can be directly accessed in an Excel spreadsheet. To evaluate the program, a detailed comparison of modeling PK data using PKSolver and professional PK/PD software package WinNonlin and Scientist was performed. The results showed that the parameters estimated with PKSolver were satisfactory. In conclusion, the PKSolver simplified the PK and PD data analysis process and its output could be generated in Microsoft Word in the form of an integrated report. The program provides pharmacokinetic researchers with a fast and easy-to-use tool for routine and basic PK and PD data analysis with a more user-friendly interface. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  1. Emissions & Generation Resource Integrated Database (eGRID), eGRID2010

    EPA Pesticide Factsheets

    The Emissions & Generation Resource Integrated Database (eGRID) is a comprehensive source of data on the environmental characteristics of almost all electric power generated in the United States. These environmental characteristics include air emissions for nitrogen oxides, sulfur dioxide, carbon dioxide, methane, and nitrous oxide; emissions rates; net generation; resource mix; and many other attributes.eGRID2010 contains the complete release of year 2007 data, as well as years 2005 and 2004 data. Excel spreadsheets, full documentation, summary data, eGRID subregion and NERC region representational maps, and GHG emission factors are included in this data set. The Archived data in eGRID2002 contain years 1996 through 2000 data.For year 2007 data, the first Microsoft Excel workbook, Plant, contains boiler, generator, and plant spreadsheets. The second Microsoft Excel workbook, Aggregation, contains aggregated data by state, electric generating company, parent company, power control area, eGRID subregion, NERC region, and U.S. total levels. The third Microsoft Excel workbook, ImportExport, contains state import-export data, as well as U.S. generation and consumption data for years 2007, 2005, and 2004. For eGRID data for years 2005 and 2004, a user friendly web application, eGRIDweb, is available to select, view, print, and export specified data.

  2. The valuable use of Microsoft Kinect™ sensor 3D kinematic in the rehabilitation process in basketball

    NASA Astrophysics Data System (ADS)

    Braidot, Ariel; Favaretto, Guillermo; Frisoli, Melisa; Gemignani, Diego; Gumpel, Gustavo; Massuh, Roberto; Rayan, Josefina; Turin, Matías

    2016-04-01

    Subjects who practice sports either as professionals or amateurs, have a high incidence of knee injuries. There are a few publications that show studies from a kinematic point of view of lateral-structure-knee injuries, including meniscal (meniscal tears or chondral injury), without anterior cruciate ligament rupture. The use of standard motion capture systems for measuring outdoors sport is hard to implement due to many operative reasons. Recently released, the Microsoft Kinect™ is a sensor that was developed to track movements for gaming purposes and has seen an increased use in clinical applications. The fact that this device is a simple and portable tool allows the acquisition of data of sport common movements in the field. The development and testing of a set of protocols for 3D kinematic measurement using the Microsoft Kinect™ system is presented in this paper. The 3D kinematic evaluation algorithms were developed from information available and with the use of Microsoft’s Software Development Kit 1.8 (SDK). Along with this, an algorithm for calculating the lower limb joints angles was implemented. Thirty healthy adult volunteers were measured, using five different recording protocols for sport characteristic gestures which involve high knee injury risk in athletes.

  3. Active X based standards for healthcare integration.

    PubMed

    Greenberg, D S; Welcker, B

    1998-02-01

    With cost pressures brought to the forefront by the growth of managed care, the integration of healthcare information systems is more important than ever. Providers of healthcare information are under increasing pressure to provide timely information to end users in a cost effective manner. Organizations have had to decide between the strong functionality that a multi-vendor 'best of breed' architecture provides and the strong integration provided by a single-vendor solution. As connectivity between systems increased, these interfaces were migrated to work across serial and eventually, network, connections. In addition, the content of the information became standardized through efforts like HL7 and ANSI X12 and Edifact. Although content-based standards go a long way towards facilitating interoperability, there is also quite a bit of work required to connect two systems even when they both adhere to the standard. A key to accomplishing this goal is increasing the connectivity between disparate systems in the healthcare environment. Microsoft is working with healthcare organizations and independent software vendors to bring Microsoft's powerful enterprise object technology, ActiveX, to the healthcare industry. Whilst object orientation has been heralded as the 'next big thing' in computer applications development, Microsoft believe that, in fact, component software is the technology which will provide the greatest benefit to end users.

  4. Rugged sensor window materials for harsh environments

    NASA Astrophysics Data System (ADS)

    Bayya, Shyam; Villalobos, Guillermo; Kim, Woohong; Sanghera, Jasbinger; Hunt, Michael; Aggarwal, Ishwar D.

    2014-09-01

    There are several military or commercial systems operating in very harsh environments that require rugged windows. On some of these systems, windows become the single point of failure. These applications include sensor or imaging systems, high-energy laser weapons systems, submarine photonic masts, IR countermeasures and missiles. Based on the sea or land or air based platforms the window or dome on these systems must withstand wave slap, underwater or ground based explosions, or survive flight through heavy rain and sand storms while maintaining good optical transmission in the desired wavelength range. Some of these applications still use softer ZnS or fused silica windows because of lack of availability of rugged materials in shapes or sizes required. Sapphire, ALON and spinel are very rugged materials with significantly higher strengths compared to ZnS and fused silica. There have been recent developments in spinel, ALON and sapphire materials to fabricate in large sizes and conformal shapes. We have been developing spinel ceramics for several of these applications. We are also developing β-SiC as a transparent window material as it has higher hardness, strength, and toughness than sapphire, ALON and spinel. This paper gives a summary of our recent findings.

  5. Algorithm improvement program nuclide identification algorithm scoring criteria and scoring application.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Enghauser, Michael

    2016-02-01

    The goal of the Domestic Nuclear Detection Office (DNDO) Algorithm Improvement Program (AIP) is to facilitate gamma-radiation detector nuclide identification algorithm development, improvement, and validation. Accordingly, scoring criteria have been developed to objectively assess the performance of nuclide identification algorithms. In addition, a Microsoft Excel spreadsheet application for automated nuclide identification scoring has been developed. This report provides an overview of the equations, nuclide weighting factors, nuclide equivalencies, and configuration weighting factors used by the application for scoring nuclide identification algorithm performance. Furthermore, this report presents a general overview of the nuclide identification algorithm scoring application including illustrative examples.

  6. Web servicing the biological office.

    PubMed

    Szugat, Martin; Güttler, Daniel; Fundel, Katrin; Sohler, Florian; Zimmer, Ralf

    2005-09-01

    Biologists routinely use Microsoft Office applications for standard analysis tasks. Despite ubiquitous internet resources, information needed for everyday work is often not directly and seamlessly available. Here we describe a very simple and easily extendable mechanism using Web Services to enrich standard MS Office applications with internet resources. We demonstrate its capabilities by providing a Web-based thesaurus for biological objects, which maps names to database identifiers and vice versa via an appropriate synonym list. The client application ProTag makes these features available in MS Office applications using Smart Tags and Add-Ins. http://services.bio.ifi.lmu.de/prothesaurus/

  7. Microsoft's Book-Search Project Has a Surprise Ending

    ERIC Educational Resources Information Center

    Foster, Andrea L.

    2008-01-01

    It is hard to imagine a Microsoft venture falling under the weight of a competitor. That's the post-mortem offered by many academic librarians as they ponder the software giant's recent and sudden announcement that it is shutting down its book-digitization project. The librarians' conclusion: Google did it. Microsoft quietly revealed in May that…

  8. Escape Excel: A tool for preventing gene symbol and accession conversion errors.

    PubMed

    Welsh, Eric A; Stewart, Paul A; Kuenzi, Brent M; Eschrich, James A

    2017-01-01

    Microsoft Excel automatically converts certain gene symbols, database accessions, and other alphanumeric text into dates, scientific notation, and other numerical representations. These conversions lead to subsequent, irreversible, corruption of the imported text. A recent survey of popular genomic literature estimates that one-fifth of all papers with supplementary gene lists suffer from this issue. Here, we present an open-source tool, Escape Excel, which prevents these erroneous conversions by generating an escaped text file that can be safely imported into Excel. Escape Excel is implemented in a variety of formats (http://www.github.com/pstew/escape_excel), including a command line based Perl script, a Windows-only Excel Add-In, an OS X drag-and-drop application, a simple web-server, and as a Galaxy web environment interface. Test server implementations are accessible as a Galaxy interface (http://apostl.moffitt.org) and simple non-Galaxy web server (http://apostl.moffitt.org:8000/). Escape Excel detects and escapes a wide variety of problematic text strings so that they are not erroneously converted into other representations upon importation into Excel. Examples of problematic strings include date-like strings, time-like strings, leading zeroes in front of numbers, and long numeric and alphanumeric identifiers that should not be automatically converted into scientific notation. It is hoped that greater awareness of these potential data corruption issues, together with diligent escaping of text files prior to importation into Excel, will help to reduce the amount of Excel-corrupted data in scientific analyses and publications.

  9. Biosurveillance applying scan statistics with multiple, disparate data sources.

    PubMed

    Burkom, Howard S

    2003-06-01

    Researchers working on the Department of Defense Global Emerging Infections System (DoD-GEIS) pilot system, the Electronic Surveillance System for the Early Notification of Community-Based Epidemics (ESSENCE), have applied scan statistics for early outbreak detection using both traditional and nontraditional data sources. These sources include medical data indexed by International Classification of Disease, 9th Revision (ICD-9) diagnosis codes, as well as less-specific, but potentially timelier, indicators such as records of over-the-counter remedy sales and of school absenteeism. Early efforts employed the Kulldorff scan statistic as implemented in the SaTScan software of the National Cancer Institute. A key obstacle to this application is that the input data streams are typically based on time-varying factors, such as consumer behavior, rather than simply on the populations of the component subregions. We have used both modeling and recent historical data distributions to obtain background spatial distributions. Data analyses have provided guidance on how to condition and model input data to avoid excessive clustering. We have used this methodology in combining data sources for both retrospective studies of known outbreaks and surveillance of high-profile events of concern to local public health authorities. We have integrated the scan statistic capability into a Microsoft Access-based system in which we may include or exclude data sources, vary time windows separately for different data sources, censor data from subsets of individual providers or subregions, adjust the background computation method, and run retrospective or simulated studies.

  10. Electronic data capture in a rural African setting: evaluating experiences with different systems in Malawi.

    PubMed

    King, Carina; Hall, Jenny; Banda, Masford; Beard, James; Bird, Jon; Kazembe, Peter; Fottrell, Ed

    2014-01-01

    As hardware for electronic data capture (EDC), such as smartphones or tablets, becomes cheaper and more widely available, the potential for using such hardware as data capture tools in routine healthcare and research is increasing. We aim to highlight the advantages and disadvantages of four EDC systems being used simultaneously in rural Malawi: two for Android devices (CommCare and ODK Collect), one for PALM and Windows OS (Pendragon), and a custom-built application for Android (Mobile InterVA--MIVA). We report on the personal field and development experience of fieldworkers, project managers, and EDC system developers. Fieldworkers preferred using EDC to paper-based systems, although some struggled with the technology at first. Highlighted features include in-built skip patterns for all systems, and specifically the 'case' function that CommCare offers. MIVA as a standalone app required considerably more time and expertise than the other systems to create and could not be customised for our specific research needs; however, it facilitates standardised routine data collection. CommCare and ODK Collect both have user-friendly web-interfaces for form development and good technical support. CommCare requires Internet to build an application and download it to a device, whereas all steps can be done offline with ODK Collect, a desirable feature in low connectivity settings. Pendragon required more complex programming of logic, using a Microsoft Access application, and generally had less technical support. Start-up costs varied between systems, and all were considered more expensive than setting up a paper-based system; however running costs were generally low and therefore thought to be cost-effective over the course of our projects. EDC offers many opportunities for efficient data collection, but brings some issues requiring consideration when designing a study; the decision of which hardware and software to use should be informed by the aim of data collection, budget, and local circumstances.

  11. Electronic data capture in a rural African setting: evaluating experiences with different systems in Malawi

    PubMed Central

    King, Carina; Hall, Jenny; Banda, Masford; Beard, James; Bird, Jon; Kazembe, Peter; Fottrell, Ed

    2014-01-01

    Background As hardware for electronic data capture (EDC), such as smartphones or tablets, becomes cheaper and more widely available, the potential for using such hardware as data capture tools in routine healthcare and research is increasing. Objective We aim to highlight the advantages and disadvantages of four EDC systems being used simultaneously in rural Malawi: two for Android devices (CommCare and ODK Collect), one for PALM and Windows OS (Pendragon), and a custom-built application for Android (Mobile InterVA – MIVA). Design We report on the personal field and development experience of fieldworkers, project managers, and EDC system developers. Results Fieldworkers preferred using EDC to paper-based systems, although some struggled with the technology at first. Highlighted features include in-built skip patterns for all systems, and specifically the ‘case’ function that CommCare offers. MIVA as a standalone app required considerably more time and expertise than the other systems to create and could not be customised for our specific research needs; however, it facilitates standardised routine data collection. CommCare and ODK Collect both have user-friendly web-interfaces for form development and good technical support. CommCare requires Internet to build an application and download it to a device, whereas all steps can be done offline with ODK Collect, a desirable feature in low connectivity settings. Pendragon required more complex programming of logic, using a Microsoft Access application, and generally had less technical support. Start-up costs varied between systems, and all were considered more expensive than setting up a paper-based system; however running costs were generally low and therefore thought to be cost-effective over the course of our projects. Conclusions EDC offers many opportunities for efficient data collection, but brings some issues requiring consideration when designing a study; the decision of which hardware and software to use should be informed by the aim of data collection, budget, and local circumstances. PMID:25363364

  12. Information Management System Development for the Investigation, Reporting, and Analysis of Human Error in Naval Aviation Maintenance

    DTIC Science & Technology

    2001-09-01

    of MEIMS was programmed in Microsoft Access 97 using Visual Basic for Applications ( VBA ). This prototype had very little documentation. The FAA...using Acess 2000 as an interface and SQL server as the database engine. Question 1: Did you have any problems accessing the program? Y / N

  13. Creating an Interactive PDF

    ERIC Educational Resources Information Center

    Branzburg, Jeffrey

    2008-01-01

    There are many ways to begin a PDF document using Adobe Acrobat. The easiest and most popular way is to create the document in another application (such as Microsoft Word) and then use the Adobe Acrobat software to convert it to a PDF. In this article, the author describes how he used Acrobat's many tools in his project--an interactive…

  14. LINUX, Virtualization, and the Cloud: A Hands-On Student Introductory Lab

    ERIC Educational Resources Information Center

    Serapiglia, Anthony

    2013-01-01

    Many students are entering Computer Science education with limited exposure to operating systems and applications other than those produced by Apple or Microsoft. This gap in familiarity with the Open Source community can quickly be bridged with a simple exercise that can also be used to strengthen two other important current computing concepts,…

  15. The Impact of Computer-Based Instruction on the Development of EFL Learners' Writing Skills

    ERIC Educational Resources Information Center

    Zaini, A.; Mazdayasna, G.

    2015-01-01

    The current study investigated the application and effectiveness of computer assisted language learning (CALL) in teaching academic writing to Iranian EFL (English as a Foreign Language) learners by means of Microsoft Word Office. To this end, 44 sophomore intermediate university students majoring in English Language and Literature at an Iranian…

  16. The Effectiveness of Web-Based Multimedia Applications Simulation in Teaching and Learning

    ERIC Educational Resources Information Center

    Ziden, Azidah Abu; Rahman, Muhammad Faizal Abdul

    2013-01-01

    This study focuses on the effectiveness of using multimedia virtual simulation in Islamic Studies in Malaysia. Virtual simulation methods embedded in Microsoft PowerPoint was used in this study to determine the effectiveness of these modes to motivate students on the topic of pilgrimage in the Islamic Studies subject. Pilgrimage topic has been…

  17. Transnational Private Authority in Education Policy in Jordan and South Africa: The Case of Microsoft Corporation

    ERIC Educational Resources Information Center

    Bhanji, Zahra

    2012-01-01

    The purpose of this article is to explore Microsoft Corporation as a new international actor shaping educational reforms and practices. This study examines how the implementation of Microsoft's global Partners in Learning (PiL) program varied and was mediated by national politics and national institutional practices in two different contexts,…

  18. MONO FOR CROSS-PLATFORM CONTROL SYSTEM ENVIRONMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nishimura, Hiroshi; Timossi, Chris

    2006-10-19

    Mono is an independent implementation of the .NET Frameworkby Novell that runs on multiple operating systems (including Windows,Linux and Macintosh) and allows any .NET compatible application to rununmodified. For instance Mono can run programs with graphical userinterfaces (GUI) developed with the C# language on Windows with VisualStudio (a full port of WinForm for Mono is in progress). We present theresults of tests we performed to evaluate the portability of our controlssystem .NET applications from MS Windows to Linux.

  19. Gait assessment using the Microsoft Xbox One Kinect: Concurrent validity and inter-day reliability of spatiotemporal and kinematic variables.

    PubMed

    Mentiplay, Benjamin F; Perraton, Luke G; Bower, Kelly J; Pua, Yong-Hao; McGaw, Rebekah; Heywood, Sophie; Clark, Ross A

    2015-07-16

    The revised Xbox One Kinect, also known as the Microsoft Kinect V2 for Windows, includes enhanced hardware which may improve its utility as a gait assessment tool. This study examined the concurrent validity and inter-day reliability of spatiotemporal and kinematic gait parameters estimated using the Kinect V2 automated body tracking system and a criterion reference three-dimensional motion analysis (3DMA) marker-based camera system. Thirty healthy adults performed two testing sessions consisting of comfortable and fast paced walking trials. Spatiotemporal outcome measures related to gait speed, speed variability, step length, width and time, foot swing velocity and medial-lateral and vertical pelvis displacement were examined. Kinematic outcome measures including ankle flexion, knee flexion and adduction and hip flexion were examined. To assess the agreement between Kinect and 3DMA systems, Bland-Altman plots, relative agreement (Pearson's correlation) and overall agreement (concordance correlation coefficients) were determined. Reliability was assessed using intraclass correlation coefficients, Cronbach's alpha and standard error of measurement. The spatiotemporal measurements had consistently excellent (r≥0.75) concurrent validity, with the exception of modest validity for medial-lateral pelvis sway (r=0.45-0.46) and fast paced gait speed variability (r=0.73). In contrast kinematic validity was consistently poor to modest, with all associations between the systems weak (r<0.50). In those measures with acceptable validity, the inter-day reliability was similar between systems. In conclusion, while the Kinect V2 body tracking may not accurately obtain lower body kinematic data, it shows great potential as a tool for measuring spatiotemporal aspects of gait. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Reliability and concurrent validity of the Microsoft Xbox One Kinect for assessment of standing balance and postural control.

    PubMed

    Clark, Ross A; Pua, Yong-Hao; Oliveira, Cristino C; Bower, Kelly J; Thilarajah, Shamala; McGaw, Rebekah; Hasanki, Ksaniel; Mentiplay, Benjamin F

    2015-07-01

    The Microsoft Kinect V2 for Windows, also known as the Xbox One Kinect, includes new and potentially far improved depth and image sensors which may increase its accuracy for assessing postural control and balance. The aim of this study was to assess the concurrent validity and reliability of kinematic data recorded using a marker-based three dimensional motion analysis (3DMA) system and the Kinect V2 during a variety of static and dynamic balance assessments. Thirty healthy adults performed two sessions, separated by one week, consisting of static standing balance tests under different visual (eyes open vs. closed) and supportive (single limb vs. double limb) conditions, and dynamic balance tests consisting of forward and lateral reach and an assessment of limits of stability. Marker coordinate and joint angle data were concurrently recorded using the Kinect V2 skeletal tracking algorithm and the 3DMA system. Task-specific outcome measures from each system on Day 1 and 2 were compared. Concurrent validity of trunk angle data during the dynamic tasks and anterior-posterior range and path length in the static balance tasks was excellent (Pearson's r>0.75). In contrast, concurrent validity for medial-lateral range and path length was poor to modest for all trials except single leg eyes closed balance. Within device test-retest reliability was variable; however, the results were generally comparable between devices. In conclusion, the Kinect V2 has the potential to be used as a reliable and valid tool for the assessment of some aspects of balance performance. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. VIS-IR transmitting BGG glass windows

    NASA Astrophysics Data System (ADS)

    Bayya, Shyam S.; Chin, Geoff D.; Sanghera, Jasbinder S.; Aggarwal, Ishwar D.

    2003-09-01

    BaO-Ga2O3-GeO2 (BGG) glasses have the desired properties for various window applications in the 0.5-5 μm wavelength region. These glasses are low cost alternatives to the currently used window materials. Fabrication of a high optical quality 18" diameter BGG glass window has been demonstrated with a transmitted wave front error of λ/10 at 632 nm. BGG substrates have also been successfully tested for environmental weatherability (MIL-F-48616) and rain erosion durability up to 300 mph. Preliminary EMI grids have been successfully applied on BGG glasses demonstrating attenuation of 20dB in X and Ku bands. Although the mechanical properties of BGG glasses are acceptable for various window applications, it is demonstrated here that the properties can be further improved significantly by the glassceramization process. The ceramization process does not add any significant cost to the final window material. The crystallite size in the present glass-ceramic limits its transmission to the 2-5 μm region.

  2. Continuation of research into software for space operations support, volume 1

    NASA Technical Reports Server (NTRS)

    Collier, Mark D.; Killough, Ronnie; Martin, Nancy L.

    1990-01-01

    A prototype workstation executive called the Hardware Independent Software Development Environment (HISDE) was developed. Software technologies relevant to workstation executives were researched and evaluated and HISDE was used as a test bed for prototyping efforts. New X Windows software concepts and technology were introduced into workstation executives and related applications. The four research efforts performed included: (1) Research into the usability and efficiency of Motif (an X Windows based graphic user interface) which consisted of converting the existing Athena widget based HISDE user interface to Motif demonstrating the usability of Motif and providing insight into the level of effort required to translate an application from widget to another; (2) Prototype a real time data display widget which consisted of research methods for and prototyping the selected method of displaying textual values in an efficient manner; (3) X Windows performance evaluation which consisted of a series of performance measurements which demonstrated the ability of low level X Windows to display textural information; (4) Convert the Display Manager to X Window/Motif which is the application used by NASA for data display during operational mode.

  3. A Novel Technique for Running the NASA Legacy Code LAPIN Synchronously With Simulations Developed Using Simulink

    NASA Technical Reports Server (NTRS)

    Vrnak, Daniel R.; Stueber, Thomas J.; Le, Dzu K.

    2012-01-01

    This report presents a method for running a dynamic legacy inlet simulation in concert with another dynamic simulation that uses a graphical interface. The legacy code, NASA's LArge Perturbation INlet (LAPIN) model, was coded using the FORTRAN 77 (The Portland Group, Lake Oswego, OR) programming language to run in a command shell similar to other applications that used the Microsoft Disk Operating System (MS-DOS) (Microsoft Corporation, Redmond, WA). Simulink (MathWorks, Natick, MA) is a dynamic simulation that runs on a modern graphical operating system. The product of this work has both simulations, LAPIN and Simulink, running synchronously on the same computer with periodic data exchanges. Implementing the method described in this paper avoided extensive changes to the legacy code and preserved its basic operating procedure. This paper presents a novel method that promotes inter-task data communication between the synchronously running processes.

  4. Performance (Off-Design) Cycle Analysis for a Turbofan Engine With Interstage Turbine Burner

    NASA Technical Reports Server (NTRS)

    Liew, K. H.; Urip, E.; Yang, S. L.; Mattingly, J. D.; Marek, C. J.

    2005-01-01

    This report presents the performance of a steady-state, dual-spool, separate-exhaust turbofan engine, with an interstage turbine burner (ITB) serving as a secondary combustor. The ITB, which is located in the transition duct between the high- and the low-pressure turbines, is a relatively new concept for increasing specific thrust and lowering pollutant emissions in modern jet-engine propulsion. A detailed off-design performance analysis of ITB engines is written in Microsoft(Registered Trademark) Excel (Redmond, Washington) macrocode with Visual Basic Application to calculate engine performances over the entire operating envelope. Several design-point engine cases are pre-selected using a parametric cycle-analysis code developed previously in Microsoft(Registered Trademark) Excel, for off-design analysis. The off-design code calculates engine performances (i.e. thrust and thrust-specific-fuel-consumption) at various flight conditions and throttle settings.

  5. Applying Fused Silica and Other Transparent Window Materials in Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Salem, Jon

    2017-01-01

    A variety of transparent ceramics, such as AlONs and spinels, that were developed for military applications hold promise as spacecraft windows. Window materials in spacecraft such as the Space Shuttle must meet many requirements such as maintaining cabin pressure, sustaining thermal shock, and tolerating damage from hyper-velocity impact while providing superior optical characteristics. The workhorse transparent material for space missions from Apollo to the International Space Station has been fused silica due in part to its low density, low coefficient of expansion and optical quality. Despite its successful use, fused silica exhibits lower fracture toughness and impact resistance as compared to newer materials. Can these newer transparent ceramics lighten spacecraft window systems and might they be useful for applications such as phone screens? This presentation will compare recent optical ceramics to fused silica and demonstrate how weight can be saved.

  6. Rigid thin windows for vacuum applications

    DOEpatents

    Meyer, Glenn Allyn; Ciarlo, Dino R.; Myers, Booth Richard; Chen, Hao-Lin; Wakalopulos, George

    1999-01-01

    A thin window that stands off atmospheric pressure is fabricated using photolithographic and wet chemical etching techniques and comprises at least two layers: an etch stop layer and a protective barrier layer. The window structure also comprises a series of support ribs running the width of the window. The windows are typically made of boron-doped silicon and silicon nitride and are useful in instruments such as electron beam guns and x-ray detectors. In an electron beam gun, the window does not impede the electrons and has demonstrated outstanding gun performance and survivability during the gun tube manufacturing process.

  7. A New Definition for Ground Control

    NASA Technical Reports Server (NTRS)

    2002-01-01

    LandForm(R) VisualFlight(R) blends the power of a geographic information system with the speed of a flight simulator to transform a user's desktop computer into a "virtual cockpit." The software product, which is fully compatible with all Microsoft(R) Windows(R) operating systems, provides distributed, real-time three-dimensional flight visualization over a host of networks. From a desktop, a user can immediately obtain a cockpit view, a chase-plane view, or an airborne tracker view. A customizable display also allows the user to overlay various flight parameters, including latitude, longitude, altitude, pitch, roll, and heading information. Rapid Imaging Software sought assistance from NASA, and the VisualFlight technology came to fruition under a Phase II SBIR contract with Johnson Space Center in 1998. Three years later, on December 13, 2001, Ken Ham successfully flew NASA's X-38 spacecraft from a remote, ground-based cockpit using LandForm VisualFlight as part of his primary situation awareness display in a flight test at Edwards Air Force Base, California.

  8. InfoTrac TFD: a microcomputer implementation of the Transcription Factor Database TFD with a graphical user interface.

    PubMed

    Hoeck, W G

    1994-06-01

    InfoTrac TFD provides a graphical user interface (GUI) for viewing and manipulating datasets in the Transcription Factor Database, TFD. The interface was developed in Filemaker Pro 2.0 by Claris Corporation, which provides cross platform compatibility between Apple Macintosh computers running System 7.0 and higher and IBM-compatibles running Microsoft Windows 3.0 and higher. TFD ASCII-tables were formatted to fit data into several custom data tables using Add/Strip, a shareware utility and Filemaker Pro's lookup feature. The lookup feature was also put to use to allow TFD data tables to become linked within a flat-file database management system. The 'Navigator', consisting of several pop-up menus listing transcription factor abbreviations, facilitates the search for transcription factor entries. Data are presented onscreen in several layouts, that can be further customized by the user. InfoTrac TFD makes the transcription factor database accessible to a much wider community of scientists by making it available on two popular microcomputer platforms.

  9. Fast and accurate resonance assignment of small-to-large proteins by combining automated and manual approaches.

    PubMed

    Niklasson, Markus; Ahlner, Alexandra; Andresen, Cecilia; Marsh, Joseph A; Lundström, Patrik

    2015-01-01

    The process of resonance assignment is fundamental to most NMR studies of protein structure and dynamics. Unfortunately, the manual assignment of residues is tedious and time-consuming, and can represent a significant bottleneck for further characterization. Furthermore, while automated approaches have been developed, they are often limited in their accuracy, particularly for larger proteins. Here, we address this by introducing the software COMPASS, which, by combining automated resonance assignment with manual intervention, is able to achieve accuracy approaching that from manual assignments at greatly accelerated speeds. Moreover, by including the option to compensate for isotope shift effects in deuterated proteins, COMPASS is far more accurate for larger proteins than existing automated methods. COMPASS is an open-source project licensed under GNU General Public License and is available for download from http://www.liu.se/forskning/foass/tidigare-foass/patrik-lundstrom/software?l=en. Source code and binaries for Linux, Mac OS X and Microsoft Windows are available.

  10. Software for Analyzing Sequences of Flow-Related Images

    NASA Technical Reports Server (NTRS)

    Klimek, Robert; Wright, Ted

    2004-01-01

    Spotlight is a computer program for analysis of sequences of images generated in combustion and fluid physics experiments. Spotlight can perform analysis of a single image in an interactive mode or a sequence of images in an automated fashion. The primary type of analysis is tracking of positions of objects over sequences of frames. Features and objects that are typically tracked include flame fronts, particles, droplets, and fluid interfaces. Spotlight automates the analysis of object parameters, such as centroid position, velocity, acceleration, size, shape, intensity, and color. Images can be processed to enhance them before statistical and measurement operations are performed. An unlimited number of objects can be analyzed simultaneously. Spotlight saves results of analyses in a text file that can be exported to other programs for graphing or further analysis. Spotlight is a graphical-user-interface-based program that at present can be executed on Microsoft Windows and Linux operating systems. A version that runs on Macintosh computers is being considered.

  11. The designing and implementation of PE teaching information resource database based on broadband network

    NASA Astrophysics Data System (ADS)

    Wang, Jian

    2017-01-01

    In order to change traditional PE teaching mode and realize the interconnection, interworking and sharing of PE teaching resources, a distance PE teaching platform based on broadband network is designed and PE teaching information resource database is set up. The designing of PE teaching information resource database takes Windows NT 4/2000Server as operating system platform, Microsoft SQL Server 7.0 as RDBMS, and takes NAS technology for data storage and flow technology for video service. The analysis of system designing and implementation shows that the dynamic PE teaching information resource sharing platform based on Web Service can realize loose coupling collaboration, realize dynamic integration and active integration and has good integration, openness and encapsulation. The distance PE teaching platform based on Web Service and the design scheme of PE teaching information resource database can effectively solve and realize the interconnection, interworking and sharing of PE teaching resources and adapt to the informatization development demands of PE teaching.

  12. Gener: a minimal programming module for chemical controllers based on DNA strand displacement

    PubMed Central

    Kahramanoğulları, Ozan; Cardelli, Luca

    2015-01-01

    Summary: Gener is a development module for programming chemical controllers based on DNA strand displacement. Gener is developed with the aim of providing a simple interface that minimizes the opportunities for programming errors: Gener allows the user to test the computations of the DNA programs based on a simple two-domain strand displacement algebra, the minimal available so far. The tool allows the user to perform stepwise computations with respect to the rules of the algebra as well as exhaustive search of the computation space with different options for exploration and visualization. Gener can be used in combination with existing tools, and in particular, its programs can be exported to Microsoft Research’s DSD tool as well as to LaTeX. Availability and implementation: Gener is available for download at the Cosbi website at http://www.cosbi.eu/research/prototypes/gener as a windows executable that can be run on Mac OS X and Linux by using Mono. Contact: ozan@cosbi.eu PMID:25957353

  13. Operation and control software for APNEA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McClelland, J.H.; Storm, B.H. Jr.; Ahearn, J.

    1997-11-01

    The human interface software for the Lockheed Martin Specialty Components (LMSC) Active/Passive Neutron Examination & Analysis System (APENA) provides a user friendly operating environment for the movement and analysis of waste drums. It is written in Microsoft Visual C++ on a Windows NT platform. Object oriented and multitasking techniques are used extensively to maximize the capability of the system. A waste drum is placed on a loading platform with a fork lift and then automatically moved into the APNEA chamber in preparation for analysis. A series of measurements is performed, controlled by menu commands to hardware components attached as peripheralmore » devices, in order to create data files for analysis. The analysis routines use the files to identify the pertinent radioactive characteristics of the drum, including the type, location, and quantity of fissionable material. At the completion of the measurement process, the drum is automatically unloaded and the data are archived in preparation for storage as part of the drum`s data signature. 3 figs.« less

  14. Beta reduction factors for protective clothing at the Oak Ridge National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Franklin, G.L.; Gonzalez, P.L.

    1998-12-31

    Beta reduction factors (f{sub {beta}}) for protective clothing (PC) at the Oak Ridge National Laboratory (ORNL) have been determined for a variety of protective clothing combinations. Data was collected to determine the experimental f{sub {beta}} for several combinations of PCs under laboratory conditions. Radiation dose rates were measured with an open window Bicron{reg_sign} RSO-5 ion chamber for two distinct beta energy groups (E{sub max} = 1.218 {times} 10{sup {minus}13} J(0.860 MeV) and 3.653 {times} 10{sup {minus}13} J (2.280 MeV)). Data points determined, as the ratio of unattenuated (no PCs) to attenuated (PCs), were used to derive a set of equationsmore » using the Microsoft{reg_sign} Excel Linet function. Field comparison tests were then conducted to determine the validity of these beta reduction factors. The f{sub {beta}} from the field tests were significantly less than the experimental f{sub {beta}}, indicating that these factors will yield conservative results.« less

  15. Fast and Accurate Resonance Assignment of Small-to-Large Proteins by Combining Automated and Manual Approaches

    PubMed Central

    Niklasson, Markus; Ahlner, Alexandra; Andresen, Cecilia; Marsh, Joseph A.; Lundström, Patrik

    2015-01-01

    The process of resonance assignment is fundamental to most NMR studies of protein structure and dynamics. Unfortunately, the manual assignment of residues is tedious and time-consuming, and can represent a significant bottleneck for further characterization. Furthermore, while automated approaches have been developed, they are often limited in their accuracy, particularly for larger proteins. Here, we address this by introducing the software COMPASS, which, by combining automated resonance assignment with manual intervention, is able to achieve accuracy approaching that from manual assignments at greatly accelerated speeds. Moreover, by including the option to compensate for isotope shift effects in deuterated proteins, COMPASS is far more accurate for larger proteins than existing automated methods. COMPASS is an open-source project licensed under GNU General Public License and is available for download from http://www.liu.se/forskning/foass/tidigare-foass/patrik-lundstrom/software?l=en. Source code and binaries for Linux, Mac OS X and Microsoft Windows are available. PMID:25569628

  16. [Establishment and management of electronic appointment library for dental implant patients].

    PubMed

    Dong, Zheng-jie; Xu, Kan

    2013-10-01

    To design an excel form which can prompt dental implant patient appointment through color change, which can scientifically manage implant EMR library through appropriate interlinkage and number. An excel form based on operating system Windows XP was designed and software 2003 Microsoft excel was used, which was configured to change color with the passage of time by the use of command "conditional format". An excel form was designed. The color turned to red automatically on the day the patient underwent implant surgery. It turned to yellow when the patient recalled 2 weeks after the first operation, to green when the patient underwent secondary operation. It was designed to be gray when all the procedures of implant restoration was finished. In addition, we could know patients' main implant situation through directly opening his EMR when clicking on his name or number. Dentists can remind the implant patient appointment schedule through color change of an excel form, and can consult the implant patient EMR directly through interlinkage or number.

  17. Gener: a minimal programming module for chemical controllers based on DNA strand displacement.

    PubMed

    Kahramanoğulları, Ozan; Cardelli, Luca

    2015-09-01

    : Gener is a development module for programming chemical controllers based on DNA strand displacement. Gener is developed with the aim of providing a simple interface that minimizes the opportunities for programming errors: Gener allows the user to test the computations of the DNA programs based on a simple two-domain strand displacement algebra, the minimal available so far. The tool allows the user to perform stepwise computations with respect to the rules of the algebra as well as exhaustive search of the computation space with different options for exploration and visualization. Gener can be used in combination with existing tools, and in particular, its programs can be exported to Microsoft Research's DSD tool as well as to LaTeX. Gener is available for download at the Cosbi website at http://www.cosbi.eu/research/prototypes/gener as a windows executable that can be run on Mac OS X and Linux by using Mono. ozan@cosbi.eu. © The Author 2015. Published by Oxford University Press.

  18. Modelling and Simulation of the Knee Joint with a Depth Sensor Camera for Prosthetics and Movement Rehabilitation

    NASA Astrophysics Data System (ADS)

    Risto, S.; Kallergi, M.

    2015-09-01

    The purpose of this project was to model and simulate the knee joint. A computer model of the knee joint was first created, which was controlled by Microsoft's Kinect for Windows. Kinect created a depth map of the knee and lower leg motion independent of lighting conditions through an infrared sensor. A combination of open source software such as Blender, Python, Kinect SDK and NI_Mate were implemented for the creation and control of the simulated knee based on movements of a live physical model. A physical size model of the knee and lower leg was also created, the movement of which was controlled remotely by the computer model and Kinect. The real time communication of the model and the robotic knee was achieved through programming in Python and Arduino language. The result of this study showed that Kinect in the modelling of human kinematics and can play a significant role in the development of prosthetics and other assistive technologies.

  19. How architecture wins technology wars.

    PubMed

    Morris, C R; Ferguson, C H

    1993-01-01

    Signs of revolutionary transformation in the global computer industry are everywhere. A roll call of the major industry players reads like a waiting list in the emergency room. The usual explanations for the industry's turmoil are at best inadequate. Scale, friendly government policies, manufacturing capabilities, a strong position in desktop markets, excellent software, top design skills--none of these is sufficient, either by itself or in combination, to ensure competitive success in information technology. A new paradigm is required to explain patterns of success and failure. Simply stated, success flows to the company that manages to establish proprietary architectural control over a broad, fast-moving, competitive space. Architectural strategies have become crucial to information technology because of the astonishing rate of improvement in microprocessors and other semiconductor components. Since no single vendor can keep pace with the outpouring of cheap, powerful, mass-produced components, customers insist on stitching together their own local systems solutions. Architectures impose order on the system and make the interconnections possible. The architectural controller is the company that controls the standard by which the entire information package is assembled. Microsoft's Windows is an excellent example of this. Because of the popularity of Windows, companies like Lotus must conform their software to its parameters in order to compete for market share. In the 1990s, proprietary architectural control is not only possible but indispensable to competitive success. What's more, it has broader implications for organizational structure: architectural competition is giving rise to a new form of business organization.

  20. U.S. Geological Survey groundwater toolbox, a graphical and mapping interface for analysis of hydrologic data (version 1.0): user guide for estimation of base flow, runoff, and groundwater recharge from streamflow data

    USGS Publications Warehouse

    Barlow, Paul M.; Cunningham, William L.; Zhai, Tong; Gray, Mark

    2015-01-01

    This report is a user guide for the streamflow-hydrograph analysis methods provided with version 1.0 of the U.S. Geological Survey (USGS) Groundwater Toolbox computer program. These include six hydrograph-separation methods to determine the groundwater-discharge (base-flow) and surface-runoff components of streamflow—the Base-Flow Index (BFI; Standard and Modified), HYSEP (Fixed Interval, Sliding Interval, and Local Minimum), and PART methods—and the RORA recession-curve displacement method and associated RECESS program to estimate groundwater recharge from streamflow data. The Groundwater Toolbox is a customized interface built on the nonproprietary, open source MapWindow geographic information system software. The program provides graphing, mapping, and analysis capabilities in a Microsoft Windows computing environment. In addition to the four hydrograph-analysis methods, the Groundwater Toolbox allows for the retrieval of hydrologic time-series data (streamflow, groundwater levels, and precipitation) from the USGS National Water Information System, downloading of a suite of preprocessed geographic information system coverages and meteorological data from the National Oceanic and Atmospheric Administration National Climatic Data Center, and analysis of data with several preprocessing and postprocessing utilities. With its data retrieval and analysis tools, the Groundwater Toolbox provides methods to estimate many of the components of the water budget for a hydrologic basin, including precipitation; streamflow; base flow; runoff; groundwater recharge; and total, groundwater, and near-surface evapotranspiration.

  1. Algorithm Improvement Program Nuclide Identification Algorithm Scoring Criteria And Scoring Application - DNDO.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Enghauser, Michael

    2015-02-01

    The goal of the Domestic Nuclear Detection Office (DNDO) Algorithm Improvement Program (AIP) is to facilitate gamma-radiation detector nuclide identification algorithm development, improvement, and validation. Accordingly, scoring criteria have been developed to objectively assess the performance of nuclide identification algorithms. In addition, a Microsoft Excel spreadsheet application for automated nuclide identification scoring has been developed. This report provides an overview of the equations, nuclide weighting factors, nuclide equivalencies, and configuration weighting factors used by the application for scoring nuclide identification algorithm performance. Furthermore, this report presents a general overview of the nuclide identification algorithm scoring application including illustrative examples.

  2. Using Animation in Microsoft PowerPoint to Enhance Engagement and Learning in Young Learners with Developmental Delay

    ERIC Educational Resources Information Center

    Parette, Howard P., Jr.; Hourcade, Jack; Blum, Craig

    2011-01-01

    Over the past decade, a wide array of instructional technology applications have found their way into early intervention settings. Of particular importance to young learners who evidence developmental delays or are at risk for school failure are those technologies with the potential to more effectively teach basic emergent literacy skills: (1)…

  3. Handling of computational in vitro/in vivo correlation problems by Microsoft Excel: I. Principles and some general algorithms.

    PubMed

    Langenbucher, Frieder

    2002-01-01

    Most computations in the field of in vitro/in vivo correlations can be handled directly by Excel worksheets, without the need for specialized software. Following a summary of Excel features, applications are illustrated for numerical computation of AUC and Mean, Wagner-Nelson and Loo-Riegelman absorption plots, and polyexponential curve fitting.

  4. 75 FR 27926 - Notice of Availability of Interpretive Rule on the Applicability of Current Water Conservation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-19

    ... the message. Comments and suggestions should be provided in WordPerfect, Microsoft Word, PDF, or text file format. The full text of the interpretive rule is available at http://www1.eere.energy.gov.... The full text of the interpretive rule is available at http://www1.eere.energy.gov/buildings/appliance...

  5. Optimal Window and Lattice in Gabor Transform. Application to Audio Analysis.

    PubMed

    Lachambre, Helene; Ricaud, Benjamin; Stempfel, Guillaume; Torrésani, Bruno; Wiesmeyr, Christoph; Onchis-Moaca, Darian

    2015-01-01

    This article deals with the use of optimal lattice and optimal window in Discrete Gabor Transform computation. In the case of a generalized Gaussian window, extending earlier contributions, we introduce an additional local window adaptation technique for non-stationary signals. We illustrate our approach and the earlier one by addressing three time-frequency analysis problems to show the improvements achieved by the use of optimal lattice and window: close frequencies distinction, frequency estimation and SNR estimation. The results are presented, when possible, with real world audio signals.

  6. The concurrent validity and intrarater reliability of the Microsoft Kinect to measure thoracic kyphosis.

    PubMed

    Quek, June; Brauer, Sandra G; Treleaven, Julia; Clark, Ross A

    2017-09-01

    This study aims to investigate the concurrent validity and intrarater reliability of the Microsoft Kinect to measure thoracic kyphosis against the Flexicurve. Thirty-three healthy individuals (age: 31±11.0 years, men: 17, height: 170.2±8.2 cm, weight: 64.2±12.0 kg) participated, with 29 re-examined for intrarater reliability 1-7 days later. Thoracic kyphosis was measured using the Flexicurve and the Microsoft Kinect consecutively in both standing and sitting positions. Both the kyphosis index and angle were calculated. The Microsoft Kinect showed excellent concurrent validity (intraclass correlation coefficient=0.76-0.82) and reliability (intraclass correlation coefficient=0.81-0.98) for measuring thoracic kyphosis (angle and index) in both standing and sitting postures. This study is the first to show that the Microsoft Kinect has excellent validity and intrarater reliability to measure thoracic kyphosis, which is promising for its use in the clinical setting.

  7. Prism Window for Optical Alignment

    NASA Technical Reports Server (NTRS)

    Tang, Hong

    2008-01-01

    A prism window has been devised for use, with an autocollimator, in aligning optical components that are (1) required to be oriented parallel to each other and/or at a specified angle of incidence with respect to a common optical path and (2) mounted at different positions along the common optical path. The prism window can also be used to align a single optical component at a specified angle of incidence. Prism windows could be generally useful for orienting optical components in manufacture of optical instruments. "Prism window" denotes an application-specific unit comprising two beam-splitter windows that are bonded together at an angle chosen to obtain the specified angle of incidence.

  8. Ocean Engineering Studies Compiled 1991. Volume 6. Acrylic Windows - Typical Applications in Pressure Housings

    DTIC Science & Technology

    1991-01-01

    either the metallic or plastic composite pressure envelope. The ASME Boiler and Pressure Vessel Code Section 8 provides such design criteria, and the...fabricated of metallic or piastic composite materials. To preclude potential catastrophic failures of windows designed on the basis of inadequate data, in...pressure-resistant acrylic windows (reference 12). Acrylic windows are usually machined from Plexiglas G plate, which is limited in thickness to 4 inches

  9. Sci—Thur AM: YIS - 10: Use of the Microsoft Kinect for applications of patient surface data to radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guillet, Dominique; Syme, Alasdair; DeBlois, François

    Current techniques to acquire patient surface data are often very expensive and lack flexibility. In this study, the use of the Microsoft Kinect to reliably acquire 3D scans of patient surface is investigated. A design is presented to make the system easily applicable to the clinic. Potential applications of the device to radiotherapy are also presented. Scan reproducibility was tested by repeatedly scanning an anthropomorphic phantom. Scan accuracy was tested by comparing Kinect scans to the surface extracted from a CT dataset of a Rando® anthropomorphic phantom, which was considered as the true reference surface. Average signed distances of 0.12more » ± 2.34 mm and 0.13 ± 2.04 mm were obtained between the compared surfaces for reproducibility and accuracy respectively. This is conclusive, since it indicates that the variations observed come largely from noise distributed around an average distance close to 0 mm. Moreover, the range of the noise is small enough for the system to reliably capture a patient's surface. A system was also designed using two Kinects used together to acquire 3D surfaces in a quick and stable way that is applicable to the clinic. Finally, applications of the device to radiotherapy are demonstrated. Its use to detect local positioning errors is presented, where small local variations difficult to see with the naked eye are clearly visible. The system was also used to predict collisions using gantry and patient scans and thus ensure the safety of unconventional trajectories.« less

  10. Why American business demands twenty-first century learning: A company perspective.

    PubMed

    Knox, Allyson

    2006-01-01

    Microsoft is an innovative corporation demonstrating the kind and caliber of job skills needed in the twenty-first century. It demonstrates its commitment to twenty-first century skills by holding its employees accountable to a set of core competencies, enabling the company to run effectively. The author explores how Microsoft's core competencies parallel the Partnership for 21st Century Skills learning frameworks. Both require advanced problem-solving skills and a passion for technology, both expect individuals to be able to work in teams, both look for a love of learning, and both call for the self-confidence to honestly self-evaluate. Microsoft also works to cultivate twenty-first century skills among future workers, investing in education to help prepare young people for competitive futures. As the need for digital literacy has become imperative, technology companies have taken the lead in facilitating technology training by partnering with schools and communities. Microsoft is playing a direct role in preparing students for what lies ahead in their careers. To further twenty-first century skills, or core competencies, among the nation's youth, Microsoft has established Partners in Learning, a program that helps education organizations build partnerships that leverage technology to improve teaching and learning. One Partners in Learning grantee is Global Kids, a nonprofit organization that trains students to design online games focused on global social issues resonating with civic and global competencies. As Microsoft believes the challenges of competing in today's economy and teaching today's students are substantial but not insurmountable, such partnerships and investments demonstrate Microsoft's belief in and commitment to twenty-first century skills.

  11. New vibration-rotation code for tetraatomic molecules exhibiting wide-amplitude motion: WAVR4

    NASA Astrophysics Data System (ADS)

    Kozin, Igor N.; Law, Mark M.; Tennyson, Jonathan; Hutson, Jeremy M.

    2004-11-01

    A general computational method for the accurate calculation of rotationally and vibrationally excited states of tetraatomic molecules is developed. The resulting program is particularly appropriate for molecules executing wide-amplitude motions and isomerizations. The program offers a choice of coordinate systems based on Radau, Jacobi, diatom-diatom and orthogonal satellite vectors. The method includes all six vibrational dimensions plus three rotational dimensions. Vibration-rotation calculations with reduced dimensionality in the radial degrees of freedom are easily tackled via constraints imposed on the radial coordinates via the input file. Program summaryTitle of program: WAVR4 Catalogue number: ADUN Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADUN Program obtainable from: CPC Program Library, Queen's University of Belfast, N. Ireland Licensing provisions: Persons requesting the program must sign the standard CPC nonprofit use license Computer: Developed under Tru64 UNIX, ported to Microsoft Windows and Sun Unix Operating systems under which the program has been tested: Tru64 Unix, Microsoft Windows, Sun Unix Programming language used: Fortran 90 Memory required to execute with typical data: case dependent No. of lines in distributed program, including test data, etc.: 11 937 No. of bytes in distributed program, including test data, etc.: 84 770 Distribution format: tar.gz Nature of physical problem: WAVR4 calculates the bound ro-vibrational levels and wavefunctions of a tetraatomic system using body-fixed coordinates based on generalised orthogonal vectors. Method of solution: The angular coordinates are treated using a finite basis representation (FBR) based on products of spherical harmonics. A discrete variable representation (DVR) [1] based on either Morse-oscillator-like or spherical-oscillator functions [2] is used for the radial coordinates. Matrix elements are computed using an efficient Gaussian quadrature in the angular coordinates and the DVR approximation in the radial coordinates. The solution of the secular problem is carried through a series of intermediate diagonalisations and truncations. Restrictions on the complexity of the problem: (1) The size of the final Hamiltonian matrix that can be practically diagonalised; (2) The DVR approximation for a radial coordinate fails for values of the coordinate near zero—this is remedied only for one radial coordinate by using analytical integration. Typical running time: problem-dependent Unusual features of the program: A user-supplied subroutine to evaluate the potential energy is a program requirement. External routines: BLAS and LAPACK are required. References: [1] J.C. Light, I.P. Hamilton, J.V. Lill, J. Chem. Phys. 92 (1985) 1400. [2] J.R. Henderson, C.R. Le Sueur, J. Tennyson, Comp. Phys. Comm. 75 (1993) 379.

  12. ModBack - simplified contaminant source zone delineation using backtracking

    NASA Astrophysics Data System (ADS)

    Thielsch, K.; Herold, M.; Ptak, T.

    2012-12-01

    Contaminated groundwater poses a serious threat to drinking water resources all over the world. Even though contaminated water might be detected in observation wells, a proper clean up is often only successful if the source of the contamination is detected and subsequently removed, contained or remediated. The high costs of groundwater remediation could be possibly significantly reduced if, from the outset, a focus is placed on source zone detection. ModBack combines several existing modelling tools in one easy to use GIS-based interface helping to delineate potential contaminant source zones in the subsurface. The software is written in Visual Basic 3.5 and uses the ArcObjects library to implement all required GIS applications. It can run without modification on any Microsoft Windows based PC with sufficient RAM and at least Microsoft .NET Framework 3.5. Using ModBack requires additional installation of the following software: Processing Modflow Pro 7.0, ModPath, CSTREAM (Bayer-Raich et al., 2003), Golden Software Surfer and Microsoft Excel. The graphical user interface of ModBack is separated into four blocks of procedures dealing with: data input, groundwater modelling, backtracking and analyses. Geographical data input includes all georeferenced information pertaining to the study site. Information on subsurface contamination is gathered either by conventional sampling of monitoring wells or by conducting integral pumping tests at control planes with a specific sampling scheme. Hydraulic data from these pumping tests together with all other available information are then used to set up a groundwater flow model of the study site, which provides the flow field for transport simulations within the subsequent contamination backtracking procedures, starting from the defined control planes. The backtracking results are then analysed within ModBack. The potential areas of contamination source presence or absence are determined based on the procedure used by Jarsjö et al. (2005). The contaminant plume length can be estimated using plume length statistics, first order rate degradation equations or calculations based on site specific hydraulic and chemical parameters. Furthermore, an analytical tool is included to identify the distribution of contaminants across a control plane. All relevant output can be graphically displayed and saved as vector data to be later used in GIS software. ModBack has been already used to delimit the zones of source presence or absence at several test sites. With ModBack, a tool is now available which enables environmental consultants, engineers and environmental agencies to delineate possible sources of contamination already at the planning stage of site investigation and remediation measures, helping to significantly reduce costs of contaminated site management. Bayer-Raich, M., Jarsjö, J., Holder, T. and Ptak, T. (2003): "Numerical estimations of contaminant mass flow rate based on concentration measurements in pumping wells", ModelCare 2002: A Few Steps Closer to Reality, IAHS Publication No. 277, 10-16. Jarsjö, J., Bayer-Raich, M., Ptak, T. (2005): "Monitoring groundwater contamination and delineating source zones at industrial sites: Uncertainty analyses using integral pumping tests", Journal of Contaminant Hydrology, 79, 107-134

  13. When are Overcomplete Representations Identifiable? Uniqueness of Tensor Decompositions Under Expansion Constraints

    DTIC Science & Technology

    2013-06-16

    Science Dept., University of California, Irvine, USA 92697. Email : a.anandkumar@uci.edu,mjanzami@uci.edu. Daniel Hsu and Sham Kakade are with...Microsoft Research New England, 1 Memorial Drive, Cambridge, MA 02142. Email : dahsu@microsoft.com, skakade@microsoft.com 1 a latent space dimensionality...Sparse coding for multitask and transfer learning. ArxXiv preprint, abs/1209.0738, 2012. [34] G.H. Golub and C.F. Van Loan. Matrix Computations. The

  14. A Simple Method for Reproducing Orbital Plots for Illustration Using Microsoft Paint and Microsoft Excel

    NASA Astrophysics Data System (ADS)

    Niebuhr, Cole

    2018-04-01

    Papers published in the astronomical community, particularly in the field of double star research, often contain plots that display the positions of the component stars relative to each other on a Cartesian coordinate plane. Due to the complexities of plotting a three-dimensional orbit into a two-dimensional image, it is often difficult to include an accurate reproduction of the orbit for comparison purposes. Methods to circumvent this obstacle do exist; however, many of these protocols result in low-quality blurred images or require specific and often expensive software. Here, a method is reported using Microsoft Paint and Microsoft Excel to produce high-quality images with an accurate reproduction of a partial orbit.

  15. Cubic spline interpolation with overlapped window and data reuse for on-line Hilbert Huang transform biomedical microprocessor.

    PubMed

    Chang, Nai-Fu; Chiang, Cheng-Yi; Chen, Tung-Chien; Chen, Liang-Gee

    2011-01-01

    On-chip implementation of Hilbert-Huang transform (HHT) has great impact to analyze the non-linear and non-stationary biomedical signals on wearable or implantable sensors for the real-time applications. Cubic spline interpolation (CSI) consumes the most computation in HHT, and is the key component for the HHT processor. In tradition, CSI in HHT is usually performed after the collection of a large window of signals, and the long latency violates the realtime requirement of the applications. In this work, we propose to keep processing the incoming signals on-line with small and overlapped data windows without sacrificing the interpolation accuracy. 58% multiplication and 73% division of CSI are saved after the data reuse between the data windows.

  16. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (UNIX VERSION)

    NASA Technical Reports Server (NTRS)

    Donnell, B.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with COOL (that is, a rule can pattern match on objects created using COOL). CLIPS 6.0 provides the capability to define functions, overloaded functions, and global variables interactively. In addition, CLIPS can be embedded within procedural code, called as a subroutine, and integrated with languages such as C, FORTRAN and Ada. CLIPS can be easily extended by a user through the use of several well-defined protocols. CLIPS provides several delivery options for programs including the ability to generate stand alone executables or to load programs from text or binary files. CLIPS 6.0 provides support for the modular development and execution of knowledge bases with the defmodule construct. CLIPS modules allow a set of constructs to be grouped together such that explicit control can be maintained over restricting the access of the constructs by other modules. This type of control is similar to global and local scoping used in languages such as C or Ada. By restricting access to deftemplate and defclass constructs, modules can function as blackboards, permitting only certain facts and instances to be seen by other modules. Modules are also used by rules to provide execution control. The CRSV (Cross-Reference, Style, and Verification) utility included with previous version of CLIPS is no longer supported. The capabilities provided by this tool are now available directly within CLIPS 6.0 to aid in the development, debugging, and verification of large rule bases. COSMIC offers four distribution versions of CLIPS 6.0: UNIX (MSC-22433), VMS (MSC-22434), MACINTOSH (MSC-22429), and IBM PC (MSC-22430). Executable files, source code, utilities, documentation, and examples are included on the program media. All distribution versions include identical source code for the command line version of CLIPS 6.0. This source code should compile on any platform with an ANSI C compiler. Each distribution version of CLIPS 6.0, except that for the Macintosh platform, includes an executable for the command line version. For the UNIX version of CLIPS 6.0, the command line interface has been successfully implemented on a Sun4 running SunOS, a DECstation running DEC RISC ULTRIX, an SGI Indigo Elan running IRIX, a DEC Alpha AXP running OSF/1, and an IBM RS/6000 running AIX. Command line interface executables are included for Sun4 computers running SunOS 4.1.1 or later and for the DEC RISC ULTRIX platform. The makefiles may have to be modified slightly to be used on other UNIX platforms. The UNIX, Macintosh, and IBM PC versions of CLIPS 6.0 each have a platform specific interface. Source code, a makefile, and an executable for the Windows 3.1 interface version of CLIPS 6.0 are provided only on the IBM PC distribution diskettes. Source code, a makefile, and an executable for the Macintosh interface version of CLIPS 6.0 are provided only on the Macintosh distribution diskettes. Likewise, for the UNIX version of CLIPS 6.0, only source code and a makefile for an X-Windows interface are provided. The X-Windows interface requires MIT's X Window System, Version 11, Release 4 (X11R4), the Athena Widget Set, and the Xmu library. The source code for the Athena Widget Set is provided on the distribution medium. The X-Windows interface has been successfully implemented on a Sun4 running SunOS 4.1.2 with the MIT distribution of X11R4 (not OpenWindows), an SGI Indigo Elan running IRIX 4.0.5, and a DEC Alpha AXP running OSF/1 1.2. The VAX version of CLIPS 6.0 comes only with the generic command line interface. ASCII makefiles for the command line version of CLIPS are provided on all the distribution media for UNIX, VMS, and DOS. Four executables are provided with the IBM PC version: a windowed interface executable for Windows 3.1 built using Borland C++ v3.1, an editor for use with the windowed interface, a command line version of CLIPS for Windows 3.1, and a 386 command line executable for DOS built using Zortech C++ v3.1. All four executables are capable of utilizing extended memory and require an 80386 CPU or better. Users needing an 8086/8088 or 80286 executable must recompile the CLIPS source code themselves. Users who wish to recompile the DOS executable using Borland C++ or MicroSoft C must use a DOS extender program to produce an executable capable of using extended memory. The version of CLIPS 6.0 for IBM PC compatibles requires DOS v3.3 or later and/or Windows 3.1 or later. It is distributed on a set of three 1.4Mb 3.5 inch diskettes. A hard disk is required. The Macintosh version is distributed in compressed form on two 3.5 inch 1.4Mb Macintosh format diskettes, and requires System 6.0.5, or higher, and 1Mb RAM. The version for DEC VAX/VMS is available in VAX BACKUP format on a 1600 BPI 9-track magnetic tape (standard distribution medium) or a TK50 tape cartridge. The UNIX version is distributed in UNIX tar format on a .25 inch streaming magnetic tape cartridge (Sun QIC-24). For the UNIX version, alternate distribution media and formats are available upon request. The CLIPS 6.0 documentation includes a User's Guide and a three volume Reference Manual consisting of Basic and Advanced Programming Guides and an Interfaces Guide. An electronic version of the documentation is provided on the distribution medium for each version: in MicroSoft Word format for the Macintosh and PC versions of CLIPS, and in both PostScript format and MicroSoft Word for Macintosh format for the UNIX and DEC VAX versions of CLIPS. CLIPS was developed in 1986 and Version 6.0 was released in 1993.

  17. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (IBM PC VERSION)

    NASA Technical Reports Server (NTRS)

    Donnell, B.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with COOL (that is, a rule can pattern match on objects created using COOL). CLIPS 6.0 provides the capability to define functions, overloaded functions, and global variables interactively. In addition, CLIPS can be embedded within procedural code, called as a subroutine, and integrated with languages such as C, FORTRAN and Ada. CLIPS can be easily extended by a user through the use of several well-defined protocols. CLIPS provides several delivery options for programs including the ability to generate stand alone executables or to load programs from text or binary files. CLIPS 6.0 provides support for the modular development and execution of knowledge bases with the defmodule construct. CLIPS modules allow a set of constructs to be grouped together such that explicit control can be maintained over restricting the access of the constructs by other modules. This type of control is similar to global and local scoping used in languages such as C or Ada. By restricting access to deftemplate and defclass constructs, modules can function as blackboards, permitting only certain facts and instances to be seen by other modules. Modules are also used by rules to provide execution control. The CRSV (Cross-Reference, Style, and Verification) utility included with previous version of CLIPS is no longer supported. The capabilities provided by this tool are now available directly within CLIPS 6.0 to aid in the development, debugging, and verification of large rule bases. COSMIC offers four distribution versions of CLIPS 6.0: UNIX (MSC-22433), VMS (MSC-22434), MACINTOSH (MSC-22429), and IBM PC (MSC-22430). Executable files, source code, utilities, documentation, and examples are included on the program media. All distribution versions include identical source code for the command line version of CLIPS 6.0. This source code should compile on any platform with an ANSI C compiler. Each distribution version of CLIPS 6.0, except that for the Macintosh platform, includes an executable for the command line version. For the UNIX version of CLIPS 6.0, the command line interface has been successfully implemented on a Sun4 running SunOS, a DECstation running DEC RISC ULTRIX, an SGI Indigo Elan running IRIX, a DEC Alpha AXP running OSF/1, and an IBM RS/6000 running AIX. Command line interface executables are included for Sun4 computers running SunOS 4.1.1 or later and for the DEC RISC ULTRIX platform. The makefiles may have to be modified slightly to be used on other UNIX platforms. The UNIX, Macintosh, and IBM PC versions of CLIPS 6.0 each have a platform specific interface. Source code, a makefile, and an executable for the Windows 3.1 interface version of CLIPS 6.0 are provided only on the IBM PC distribution diskettes. Source code, a makefile, and an executable for the Macintosh interface version of CLIPS 6.0 are provided only on the Macintosh distribution diskettes. Likewise, for the UNIX version of CLIPS 6.0, only source code and a makefile for an X-Windows interface are provided. The X-Windows interface requires MIT's X Window System, Version 11, Release 4 (X11R4), the Athena Widget Set, and the Xmu library. The source code for the Athena Widget Set is provided on the distribution medium. The X-Windows interface has been successfully implemented on a Sun4 running SunOS 4.1.2 with the MIT distribution of X11R4 (not OpenWindows), an SGI Indigo Elan running IRIX 4.0.5, and a DEC Alpha AXP running OSF/1 1.2. The VAX version of CLIPS 6.0 comes only with the generic command line interface. ASCII makefiles for the command line version of CLIPS are provided on all the distribution media for UNIX, VMS, and DOS. Four executables are provided with the IBM PC version: a windowed interface executable for Windows 3.1 built using Borland C++ v3.1, an editor for use with the windowed interface, a command line version of CLIPS for Windows 3.1, and a 386 command line executable for DOS built using Zortech C++ v3.1. All four executables are capable of utilizing extended memory and require an 80386 CPU or better. Users needing an 8086/8088 or 80286 executable must recompile the CLIPS source code themselves. Users who wish to recompile the DOS executable using Borland C++ or MicroSoft C must use a DOS extender program to produce an executable capable of using extended memory. The version of CLIPS 6.0 for IBM PC compatibles requires DOS v3.3 or later and/or Windows 3.1 or later. It is distributed on a set of three 1.4Mb 3.5 inch diskettes. A hard disk is required. The Macintosh version is distributed in compressed form on two 3.5 inch 1.4Mb Macintosh format diskettes, and requires System 6.0.5, or higher, and 1Mb RAM. The version for DEC VAX/VMS is available in VAX BACKUP format on a 1600 BPI 9-track magnetic tape (standard distribution medium) or a TK50 tape cartridge. The UNIX version is distributed in UNIX tar format on a .25 inch streaming magnetic tape cartridge (Sun QIC-24). For the UNIX version, alternate distribution media and formats are available upon request. The CLIPS 6.0 documentation includes a User's Guide and a three volume Reference Manual consisting of Basic and Advanced Programming Guides and an Interfaces Guide. An electronic version of the documentation is provided on the distribution medium for each version: in MicroSoft Word format for the Macintosh and PC versions of CLIPS, and in both PostScript format and MicroSoft Word for Macintosh format for the UNIX and DEC VAX versions of CLIPS. CLIPS was developed in 1986 and Version 6.0 was released in 1993.

  18. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (MACINTOSH VERSION)

    NASA Technical Reports Server (NTRS)

    Riley, G.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with COOL (that is, a rule can pattern match on objects created using COOL). CLIPS 6.0 provides the capability to define functions, overloaded functions, and global variables interactively. In addition, CLIPS can be embedded within procedural code, called as a subroutine, and integrated with languages such as C, FORTRAN and Ada. CLIPS can be easily extended by a user through the use of several well-defined protocols. CLIPS provides several delivery options for programs including the ability to generate stand alone executables or to load programs from text or binary files. CLIPS 6.0 provides support for the modular development and execution of knowledge bases with the defmodule construct. CLIPS modules allow a set of constructs to be grouped together such that explicit control can be maintained over restricting the access of the constructs by other modules. This type of control is similar to global and local scoping used in languages such as C or Ada. By restricting access to deftemplate and defclass constructs, modules can function as blackboards, permitting only certain facts and instances to be seen by other modules. Modules are also used by rules to provide execution control. The CRSV (Cross-Reference, Style, and Verification) utility included with previous version of CLIPS is no longer supported. The capabilities provided by this tool are now available directly within CLIPS 6.0 to aid in the development, debugging, and verification of large rule bases. COSMIC offers four distribution versions of CLIPS 6.0: UNIX (MSC-22433), VMS (MSC-22434), MACINTOSH (MSC-22429), and IBM PC (MSC-22430). Executable files, source code, utilities, documentation, and examples are included on the program media. All distribution versions include identical source code for the command line version of CLIPS 6.0. This source code should compile on any platform with an ANSI C compiler. Each distribution version of CLIPS 6.0, except that for the Macintosh platform, includes an executable for the command line version. For the UNIX version of CLIPS 6.0, the command line interface has been successfully implemented on a Sun4 running SunOS, a DECstation running DEC RISC ULTRIX, an SGI Indigo Elan running IRIX, a DEC Alpha AXP running OSF/1, and an IBM RS/6000 running AIX. Command line interface executables are included for Sun4 computers running SunOS 4.1.1 or later and for the DEC RISC ULTRIX platform. The makefiles may have to be modified slightly to be used on other UNIX platforms. The UNIX, Macintosh, and IBM PC versions of CLIPS 6.0 each have a platform specific interface. Source code, a makefile, and an executable for the Windows 3.1 interface version of CLIPS 6.0 are provided only on the IBM PC distribution diskettes. Source code, a makefile, and an executable for the Macintosh interface version of CLIPS 6.0 are provided only on the Macintosh distribution diskettes. Likewise, for the UNIX version of CLIPS 6.0, only source code and a makefile for an X-Windows interface are provided. The X-Windows interface requires MIT's X Window System, Version 11, Release 4 (X11R4), the Athena Widget Set, and the Xmu library. The source code for the Athena Widget Set is provided on the distribution medium. The X-Windows interface has been successfully implemented on a Sun4 running SunOS 4.1.2 with the MIT distribution of X11R4 (not OpenWindows), an SGI Indigo Elan running IRIX 4.0.5, and a DEC Alpha AXP running OSF/1 1.2. The VAX version of CLIPS 6.0 comes only with the generic command line interface. ASCII makefiles for the command line version of CLIPS are provided on all the distribution media for UNIX, VMS, and DOS. Four executables are provided with the IBM PC version: a windowed interface executable for Windows 3.1 built using Borland C++ v3.1, an editor for use with the windowed interface, a command line version of CLIPS for Windows 3.1, and a 386 command line executable for DOS built using Zortech C++ v3.1. All four executables are capable of utilizing extended memory and require an 80386 CPU or better. Users needing an 8086/8088 or 80286 executable must recompile the CLIPS source code themselves. Users who wish to recompile the DOS executable using Borland C++ or MicroSoft C must use a DOS extender program to produce an executable capable of using extended memory. The version of CLIPS 6.0 for IBM PC compatibles requires DOS v3.3 or later and/or Windows 3.1 or later. It is distributed on a set of three 1.4Mb 3.5 inch diskettes. A hard disk is required. The Macintosh version is distributed in compressed form on two 3.5 inch 1.4Mb Macintosh format diskettes, and requires System 6.0.5, or higher, and 1Mb RAM. The version for DEC VAX/VMS is available in VAX BACKUP format on a 1600 BPI 9-track magnetic tape (standard distribution medium) or a TK50 tape cartridge. The UNIX version is distributed in UNIX tar format on a .25 inch streaming magnetic tape cartridge (Sun QIC-24). For the UNIX version, alternate distribution media and formats are available upon request. The CLIPS 6.0 documentation includes a User's Guide and a three volume Reference Manual consisting of Basic and Advanced Programming Guides and an Interfaces Guide. An electronic version of the documentation is provided on the distribution medium for each version: in MicroSoft Word format for the Macintosh and PC versions of CLIPS, and in both PostScript format and MicroSoft Word for Macintosh format for the UNIX and DEC VAX versions of CLIPS. CLIPS was developed in 1986 and Version 6.0 was released in 1993.

  19. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (DEC VAX VMS VERSION)

    NASA Technical Reports Server (NTRS)

    Donnell, B.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with COOL (that is, a rule can pattern match on objects created using COOL). CLIPS 6.0 provides the capability to define functions, overloaded functions, and global variables interactively. In addition, CLIPS can be embedded within procedural code, called as a subroutine, and integrated with languages such as C, FORTRAN and Ada. CLIPS can be easily extended by a user through the use of several well-defined protocols. CLIPS provides several delivery options for programs including the ability to generate stand alone executables or to load programs from text or binary files. CLIPS 6.0 provides support for the modular development and execution of knowledge bases with the defmodule construct. CLIPS modules allow a set of constructs to be grouped together such that explicit control can be maintained over restricting the access of the constructs by other modules. This type of control is similar to global and local scoping used in languages such as C or Ada. By restricting access to deftemplate and defclass constructs, modules can function as blackboards, permitting only certain facts and instances to be seen by other modules. Modules are also used by rules to provide execution control. The CRSV (Cross-Reference, Style, and Verification) utility included with previous version of CLIPS is no longer supported. The capabilities provided by this tool are now available directly within CLIPS 6.0 to aid in the development, debugging, and verification of large rule bases. COSMIC offers four distribution versions of CLIPS 6.0: UNIX (MSC-22433), VMS (MSC-22434), MACINTOSH (MSC-22429), and IBM PC (MSC-22430). Executable files, source code, utilities, documentation, and examples are included on the program media. All distribution versions include identical source code for the command line version of CLIPS 6.0. This source code should compile on any platform with an ANSI C compiler. Each distribution version of CLIPS 6.0, except that for the Macintosh platform, includes an executable for the command line version. For the UNIX version of CLIPS 6.0, the command line interface has been successfully implemented on a Sun4 running SunOS, a DECstation running DEC RISC ULTRIX, an SGI Indigo Elan running IRIX, a DEC Alpha AXP running OSF/1, and an IBM RS/6000 running AIX. Command line interface executables are included for Sun4 computers running SunOS 4.1.1 or later and for the DEC RISC ULTRIX platform. The makefiles may have to be modified slightly to be used on other UNIX platforms. The UNIX, Macintosh, and IBM PC versions of CLIPS 6.0 each have a platform specific interface. Source code, a makefile, and an executable for the Windows 3.1 interface version of CLIPS 6.0 are provided only on the IBM PC distribution diskettes. Source code, a makefile, and an executable for the Macintosh interface version of CLIPS 6.0 are provided only on the Macintosh distribution diskettes. Likewise, for the UNIX version of CLIPS 6.0, only source code and a makefile for an X-Windows interface are provided. The X-Windows interface requires MIT's X Window System, Version 11, Release 4 (X11R4), the Athena Widget Set, and the Xmu library. The source code for the Athena Widget Set is provided on the distribution medium. The X-Windows interface has been successfully implemented on a Sun4 running SunOS 4.1.2 with the MIT distribution of X11R4 (not OpenWindows), an SGI Indigo Elan running IRIX 4.0.5, and a DEC Alpha AXP running OSF/1 1.2. The VAX version of CLIPS 6.0 comes only with the generic command line interface. ASCII makefiles for the command line version of CLIPS are provided on all the distribution media for UNIX, VMS, and DOS. Four executables are provided with the IBM PC version: a windowed interface executable for Windows 3.1 built using Borland C++ v3.1, an editor for use with the windowed interface, a command line version of CLIPS for Windows 3.1, and a 386 command line executable for DOS built using Zortech C++ v3.1. All four executables are capable of utilizing extended memory and require an 80386 CPU or better. Users needing an 8086/8088 or 80286 executable must recompile the CLIPS source code themselves. Users who wish to recompile the DOS executable using Borland C++ or MicroSoft C must use a DOS extender program to produce an executable capable of using extended memory. The version of CLIPS 6.0 for IBM PC compatibles requires DOS v3.3 or later and/or Windows 3.1 or later. It is distributed on a set of three 1.4Mb 3.5 inch diskettes. A hard disk is required. The Macintosh version is distributed in compressed form on two 3.5 inch 1.4Mb Macintosh format diskettes, and requires System 6.0.5, or higher, and 1Mb RAM. The version for DEC VAX/VMS is available in VAX BACKUP format on a 1600 BPI 9-track magnetic tape (standard distribution medium) or a TK50 tape cartridge. The UNIX version is distributed in UNIX tar format on a .25 inch streaming magnetic tape cartridge (Sun QIC-24). For the UNIX version, alternate distribution media and formats are available upon request. The CLIPS 6.0 documentation includes a User's Guide and a three volume Reference Manual consisting of Basic and Advanced Programming Guides and an Interfaces Guide. An electronic version of the documentation is provided on the distribution medium for each version: in MicroSoft Word format for the Macintosh and PC versions of CLIPS, and in both PostScript format and MicroSoft Word for Macintosh format for the UNIX and DEC VAX versions of CLIPS. CLIPS was developed in 1986 and Version 6.0 was released in 1993.

  20. Optical Characterization of Window Materials for Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Tedjojuwono, Ken K.; Clark, Natalie; Humphreys, William M., Jr.

    2013-01-01

    An optical metrology laboratory has been developed to characterize the optical properties of optical window materials to be used for aerospace applications. Several optical measurement systems have been selected and developed to measure spectral transmittance, haze, clarity, birefringence, striae, wavefront quality, and wedge. In addition to silica based glasses, several optical lightweight polymer materials and transparent ceramics have been investigated in the laboratory. The measurement systems and selected empirical results for non-silica materials are described. These measurements will be used to form the basis of acceptance criteria for selection of window materials for future aerospace vehicle and habitat designs.

Top