Investigating the Use of Ultrasonic Guided Waves for Aging Wire Insulation Assessment
NASA Technical Reports Server (NTRS)
Anastasi, Robert F.; Madaras, Eric I.
2002-01-01
Aging wiring has become a critical issue to DoD, NASA, FAA, and Industry. The problem is that insulation on environmentally aged wire becomes brittle and cracks. This exposes the underlying conductive wire to the potential for short circuits and fire. The difficulty is that techniques to monitor aging wire problems focus on applying electrical sensing techniques that are not very sensitive to the wire insulation. Thus, the development of methods to quantify and monitor aging wire insulation is highly warranted. Measurement of wire insulation stiffness by ultrasonic guided waves is being examined. Initial laboratory tests were performed on a simple model consisting of a solid cylinder and then a solid cylinder with a polymer coating. Experimental measurements showed that the lowest order axisymmetric mode may be sensitive to stiffness changes in the wire insulation. To test this theory, mil-spec wire samples MIL-W-81381, MIL-W-22759/34, and MIL-W-22759/87 (typically found in aircraft) were heat-damaged in an oven, in a range of heating conditions. The samples were 12, 16, and 20 gauge and the heat-damage introduced material changes in the wire-insulation that made the originally flexible insulation brittle and darker in color. Axisymmetric mode phase velocity increased for the samples that were exposed to heat for longer duration. For example, the phase velocity in the 20-gauge MIL-W-22759/34 wire changed from a baseline value of 2790m/s to 3280m/s and 3530m/s for one-hour exposures to 3490C and 3990C, respectively. Although the heat-damage conditions are not the same as environmental aging, we believe that with further development and refinements, the ultrasonic guided waves can be used to inspect wire-insulation for detrimental environmental aging conditions.
2001-10-01
SAE Rings, Sealing, Butadiene-Acrylonitrile ( NBR ), Rubber Fuel and Low Temperature Resistant 60 - 70 MIL-R-83248C Rubber , Fluorocarbon...KAPTON/TEFLON (COMPOSITE) WIRE I.I.10 34 VI. REFERENCE DOCUMENTS Non-Metallics MIL-HDBK-149B Military Standardization Hand Book Rubber ...ASTM D-1414 Standard Test Methods for Rubber O-Rings ASTM D-412 Type II Standard Test Methods for Vulcanized Rubber and Thermoplastic
Engineering and Design. Containment and Disposal of Aqueous Film-Forming Foam Solution
1997-05-23
Aqueous Film-Forming Foam (AFFF) concentrate used in DoD facilities must be "MIL-SPEC" foam conforming to MIL - F - 24385 . MIL-SPEC foam is recognized...requirements, the MIL - F - 24385 provides for important chemical and physical properties not specified by other standards. "MIL-SPEC" AFFF concentrate...is the standard by which others are measured. Other commercially available AFFF concentrates are simply not comparable to those conforming to MIL - F - 24385 . 3.2
Aging Wire Insulation Assessment by Phase Spectrum Examination of Ultrasonic Guided Waves
NASA Technical Reports Server (NTRS)
Anastasi, Robert F.; Madaras, Eric I.
2003-01-01
Wire integrity has become an area of concern to the aerospace community including DoD, NASA, FAA, and Industry. Over time and changing environmental conditions, wire insulation can become brittle and crack. The cracks expose the wire conductor and can be a source of equipment failure, short circuits, smoke, and fire. The technique of using the ultrasonic phase spectrum to extract material properties of the insulation is being examined. Ultrasonic guided waves will propagate in both the wire conductor and insulation. Assuming the condition of the conductor remains constant then the stiffness of the insulator can be determined by measuring the ultrasonic guided wave velocity. In the phase spectrum method the guided wave velocity is obtained by transforming the time base waveform to the frequency domain and taking the phase difference between two waveforms. The result can then be correlated with a database, derived by numerical model calculations, to extract material properties of the wire insulator. Initial laboratory tests were performed on a simple model consisting of a solid cylinder and then a solid cylinder with a polymer coating. For each sample the flexural mode waveform was identified. That waveform was then transformed to the frequency domain and a phase spectrum was calculated from a pair of waveforms. Experimental results on the simple model compared well to numerical calculations. Further tests were conducted on aircraft or mil-spec wire samples, to see if changes in wire insulation stiffness can be extracted using the phase spectrum technique.
Evaluating Thermally Damaged Polyimide Insulated Wiring (MIL-W-81381) with Ultrasound
NASA Technical Reports Server (NTRS)
Madaras, Eric I.; Anastasi, Robert F.
2002-01-01
A series of experiments to investigate the use of ultrasound for measuring wire insulation have been conducted. Initial laboratory tests were performed on MIL-W-81381/7,/12, and /21 aviation wire, a wire that has polyimide (Kapton Registered Trademark) layers for insulation. Samples of this wiring were exposed to 370C temperatures for different periods of time to induce a range of thermal damage. For each exposure, 12 samples of each gauge (12, 16, and 20 gauges) were processed. The velocity of the lowest order axisymmetric ultrasonic guided mode, a mode that is sensitive to the geometry and stiffness of the wire conductor and insulation, was measured. The phase velocity for the 20-gauge MIL-W-81381/7 wire had a baseline value of 3023 +/- 78 m/s. After exposure to the high temperatures, the wire's phase velocity rapidly increased, and reached an asymptotic value of 3598 +/- 20 m/s after 100 hours exposure. Similar behavior was measured for the 16 gauge MIL-W-81381/21 wire and 12 gauge MIL-W-81381/12 wire which had baseline values of 3225 +/- 22 m/s and 3403 +/- 33 m/s respectively, and reached asymptotic values of 3668 +/- 19 m/s, and 3679 +/- 42 m/s respectively. These measured velocity changes represent changes of 19, 14, and 8 percent respectively for the 20, 16, and 12 gauge wires. Finally, some results for a wire with an ethylene tetrafluoroethylene insulation are reported. Qualitatively similar behaviors are noted ultrasonically.
Investigating the Use of Ultrasound for Evaluating Aging Wiring Insulation
NASA Technical Reports Server (NTRS)
Madaras, Eric I.; Anastasi, Robert F.
2001-01-01
This paper reviews our initial efforts to investigate the use of ultrasound to evaluate wire insulation. Our initial model was a solid conductor with heat shrink tubing applied. In this model, various wave modes were identified. Subsequently, several aviation classes of wires (MIL-W- 81381, MIL-W-22759/34, and MIL-W-22759/87) were measured. The wires represented polyimide and ethylene-tetraflouroethylene insulations, and combinations of polyimide and flouropolymer plastics. Wire gages of 12, 16, and 20 AWG sizes were measured. Finally, samples of these wires were subjected to high temperatures for short periods of time to cause the insulation to degrade. Subsequent measurements indicated easily detectable changes.
1989-08-04
Date Owners Declaration I, the undersigned, representing agree that as part of the joint Marketing Agreement between Roim Mil-Spec and Data General for...possible. Format pragma NLINE (name (, namei): Where: name Specfies the subprogram or neric unit you want inLined at each calL The subprogam or
1989-08-04
undersigned, representing /-- /Wz agree that as part of the joint Marketing Agreement between Rolm Mil-Spec and Data General for the Ada Development...the assembly (e wkhout the pragma. Source Code in the folowing emaple, prama NLINE applie to all tb calls to SQUARE in WrrH INLINF. procedure WITH
NASA Technical Reports Server (NTRS)
Teverovsky, Alexander
2011-01-01
Presentation discusses: (1) Why Multi-Layer Ceramic Capacitors(MLCCs) crack during manual soldering? Workmanship and parts issues. (2) Do existing qualification requirements assure crack-free soldering? MIL-spec Thermal Shock (TS) testing. MIL-spec Resistance to Soldering Heat (RSH) test. (3) What test can assure reliable soldering? Mechanical characteristics of ceramics. Comparison of three TS techniques: LND, TSD, and IWT. (4) Simulation of TS conditions.
2009-12-01
11 7 MIL - F -24385F specifications for unleaded gasoline in a 28 ft2pan ......................................14 8...successfully extinguish these fires. 1.2 Scope This program was designed to determine if Military Specification MIL - F -24385F ( MIL - SPEC) AFFF has the...To aid Air Force firefighters’ response to an incident involving SPK fuels, this program was designed to determine if Military Specification MIL - F
NASA Technical Reports Server (NTRS)
Reynolds, Philip
1987-01-01
The current situation relative to the military specification is that there is not one specific model of turbulence which people are using. Particular disagreement exists on how turbulence levels will vary with qualitative analysis. It does not tie one down to specifics. When it comes to flying quality specifications, many feel that one should stay with the definitions of the Cooper-Harper rating scale but allow the levels to shift depending on the level of turbulence. There is a ride quality specification in the MIL-SPEC having to do with flight control systems design that is related to a turbulence model. This spec (MIL-F8785C) and others are discussed.
Discrete Gust Model for Launch Vehicle Assessments
NASA Technical Reports Server (NTRS)
Leahy, Frank B.
2008-01-01
Analysis of spacecraft vehicle responses to atmospheric wind gusts during flight is important in the establishment of vehicle design structural requirements and operational capability. Typically, wind gust models can be either a spectral type determined by a random process having a wide range of wavelengths, or a discrete type having a single gust of predetermined magnitude and shape. Classical discrete models used by NASA during the Apollo and Space Shuttle Programs included a 9 m/sec quasi-square-wave gust with variable wavelength from 60 to 300 m. A later study derived discrete gust from a military specification (MIL-SPEC) document that used a "1-cosine" shape. The MIL-SPEC document contains a curve of non-dimensional gust magnitude as a function of non-dimensional gust half-wavelength based on the Dryden spectral model, but fails to list the equation necessary to reproduce the curve. Therefore, previous studies could only estimate a value of gust magnitude from the curve, or attempt to fit a function to it. This paper presents the development of the MIL-SPEC curve, and provides the necessary information to calculate discrete gust magnitudes as a function of both gust half-wavelength and the desired probability level of exceeding a specified gust magnitude.
Techniques for the determination of mass properties of earth-to-orbit transportation systems
NASA Technical Reports Server (NTRS)
Macconochie, I. O.; Klich, P. J.
1978-01-01
One estimating technique involves trending whereby projections of overall mass properties of vehicles are determined with few inputs. The second technique involves trending of individual subsystems using equations of the form KXN to the nth power or KX. Some constants and exponentials are provided for sample subsystems. Mass properties are reported in a format recommended by mil spec - 38310.
Extrusion of metal oxide superconducting wire, tube or ribbon
Dusek, Joseph T.
1993-10-05
A process for extruding a superconducting metal oxide composition YBa.sub.2 Cu.sub.3 O.sub.7-x provides a wire (tube or ribbon) having a cohesive mass and a degree of flexibility together with enhanced electrical properties. Wire diameters in the range of 6-85 mils have been produced with smaller wires on the order of 10 mils in diameter exhibiting enhanced flexibility for forming braided, or multistrand, configurations for greater current carrying capacity. The composition for extrusion contains a polymeric binder to provide a cohesive mass to bind the particles together during the extrusion process with the binder subsequently removed at lower temperatures during sintering. The composition for extrusion further includes a deflocculent, an organic plasticizer and a solvent which also are subsequently removed during sintering. Electrically conductive tubing with an inner diameter of 52 mil and an outer diameter of 87-355 mil has also been produced. Flat ribbons have been produced in the range of 10-125 mil thick by 100-500 mil wide. The superconducting wire, tube or ribbon may include an outer ceramic insulating sheath co-extruded with the wire, tubing or ribbon.
Extrusion of metal oxide superconducting wire, tube or ribbon
Dusek, Joseph T.
1993-01-01
A process for extruding a superconducting metal oxide composition YBa.sub.2 Cu.sub.3 O.sub.7-x provides a wire (tube or ribbon) having a cohesive mass and a degree of flexibility together with enhanced electrical properties. Wire diameters in the range of 6-85 mils have been produced with smaller wires on the order of 10 mils in diameter exhibiting enhanced flexibility for forming braided, or multistrand, configurations for greater current carrying capacity. The composition for extrusion contains a polymeric binder to provide a cohesive mass to bind the particles together during the extrusion process with the binder subsequently removed at lower temperatures during sintering. The composition for extrusion further includes a deflocculent, an organic plasticizer and a solvent which also are subsequently removed during sintering. Electrically conductive tubing with an inner diameter of 52 mil and an outer diameter of 87-355 mil has also been produced. Flat ribbons have been produced in the range of 10-125 mil thick by 100-500 mil wide. The superconducting wire, tube or ribbon may include an outer ceramic insulating sheath co-extruded with the wire, tubing or ribbon.
Aquatic Toxicity Screening of Fire Fighting Agents
2005-09-21
Aqueous Film Forming Foam ( AFFF ), the reference toxicant. The aquatic toxicity...Specification MIL-F-24385F Fire Extinguishing Agent, Aqueous Film Forming Foam ( AFFF ) Liquid Concentrate, For Fresh and Sea Water (MIL SPEC AFFF ). This...extinguish liquid hydrocarbon fuel fires involving aircraft operations. Several types of foam exist including protein, fluoroprotein and aqueous film
1994-08-01
version of the MIL SPEC, MIL - F - 24385 Rev. F’ 3. Figure 1 shows the results of the "modeling" experiments. This shows that, for a control time of 60...the military specification, MiL - F - 24385 ’. It was noted in the Background Section that the FAA does not have specific test criteria for foam agents, The...SPECIFICATION TESTS FOR FOAM Type of Foam_ United States/North America UL 162 All types MIL - F - 24385 A,14FT OF 555 Protein 2?GP74 (Canada) AFFF L-urope
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huff, Johnathon; McLean, Michael B.; Jenkins, Mark W.
2013-05-01
In microcircuit fabrication, the diameter and length of a bond wire have been shown to both affect the current versus fusing time ratio of a bond wire as well as the gap length of the fused wire. This study investigated the impact of current level on the time-to-open and gap length of 1 mil by 60 mil gold bond wires. During the experiments, constant current was provided for a control set of bond wires for 250ms, 410ms and until the wire fused; non-destructively pull-tested wires for 250ms; and notched wires. The key findings were that as the current increases, themore » gap length increases and 73% of the bond wires will fuse at 1.8A, and 100% of the wires fuse at 1.9A within 60ms. Due to the limited scope of experiments and limited data analyzed, further investigation is encouraged to confirm these observations.« less
NASA Technical Reports Server (NTRS)
Madaras, Eric I.; Anastasi, Robert F.
2002-01-01
Ultrasonic measurements were performed on MIL-W-81381/7, /12, and /21 wire, a polyimide (Kapton) insulated wire. The phase velocity for the 20-gauge MIL-W-81381/7 wire had a baseline value of 3023 plus or minus 78 m/s. After exposure to high temperatures, the wire's phase velocity rapidly increased, and reached an asymptotic value of 3598 plus or minus 20 m/s after 100 hours exposure. Similar responses were measured in other gauges. The baseline measurements of Young's moduli resulted in values of 5636 plus or minus 486, 7714 plus or minus 505, and 8767 plus or minus 292 KSI for the 20 ga, 16 ga, and 12 ga. wires respectively.
NASA Astrophysics Data System (ADS)
Kudtarkar, Santosh Anil
Microelectronics technology has been undergoing continuous scaling to accommodate customer driven demand for smaller, faster and cheaper products. This demand has been satisfied by using novel materials, design techniques and processes. This results in challenges for the chip connection technology and also the package technology. The focus of this research endeavor was restricted to wire bond interconnect technology using gold bonding wires. Wire bond technology is often regarded as a simple first level interconnection technique. In reality, however, this is a complex process that requires a thorough understanding of the interactions between the design, material and process variables, and their impact on the reliability of the bond formed during this process. This research endeavor primarily focused on low diameter, 0.8 mil thick (20 mum) diameter gold bonding wire. Within the scope of this research, the integrity of the ball bond formed by 1.0 mil (25 mum) and 0.8 mil (20 mum) diameter wires was compared. This was followed by the evaluation of bonds formed on bond pads having doped SiO2 (low k) as underlying structures. In addition, the effect of varying the percentage of the wire dopant, palladium and bonding process parameters (bonding force, bond time, ultrasonic energy) for 0.8 mil (20 mum) bonding wire was also evaluated. Finally, a degradation empirical model was developed to understand the decrease in the wire strength. This research effort helped to develop a fundamental understanding of the various factors affecting the reliability of a ball bond from a design (low diameter bonding wire), material (low k and bonding wire dopants), and process (wire bonding process parameters) perspective for a first level interconnection technique, namely wire bonding. The significance of this research endeavor was the systematic investigation of the ball bonds formed using 0.8 mil (20 microm) gold bonding wire within the wire bonding arena. This research addressed low k structures on 90 nm silicon technology, bonding wires with different percentage of doping element (palladium), and different levels of bonding process parameters. An empirical model to understand the high temperature effects for bonds formed using the low diameter wire was also developed.
Investigation of factors affecting the heater wire method of calibrating fine wire thermocouples
NASA Technical Reports Server (NTRS)
Keshock, E. G.
1972-01-01
An analytical investigation was made of a transient method of calibrating fine wire thermocouples. The system consisted of a 10 mil diameter standard thermocouple (Pt, Pt-13% Rh) and an 0.8 mil diameter chromel-alumel thermocouple attached to a 20 mil diameter electrically heated platinum wire. The calibration procedure consisted of electrically heating the wire to approximately 2500 F within about a seven-second period in an environment approximating atmospheric conditions at 120,000 feet. Rapid periodic readout of the standard and fine wire thermocouple signals permitted a comparison of the two temperature indications. An analysis was performed which indicated that the temperature distortion at the heater wire produced by the thermocouple junctions appears to be of negligible magnitude. Consequently, the calibration technique appears to be basically sound, although several practical changes which appear desirable are presented and discussed. Additional investigation is warranted to evaluate radiation effects and transient response characteristics.
Thorstenson, Glenys A; Kusy, Robert P
2002-09-01
When paired with a particular self-ligating bracket design, the material and the geometric characteristics of an archwire influence its resistance to sliding. Four designs of self-ligating brackets (1 with a slide, 3 with clips) were coupled with 5 types of archwires: 14-mil round austenitic nickel-titanium, 16 x 22-mil rectangular austenitic nickel-titanium, 19 x 25-mil rectangular austenitic nickel-titanium, 19 x 25-mil rectangular martensitic nickel-titanium, and 19 x 25-mil rectangular stainless steel. The resistance to sliding (RS) of each archwire-bracket couple was measured at second-order angles between -9 degrees and 9 degrees. Interbracket distances of 8 and 18 mm between the test bracket and the adjacent brackets mimicked closure of a premolar extraction. When clearance exists, the RS is negligible for self-ligating brackets with slides coupled to any size of wire as well as for those with clips when coupled to wires that do not contact the clip. Once the wire attains a certain size and contacts the clip, the RS depends on the archwire size, the bracket design, and the materials of the couple. When coupled with the 16 x 22-mil wire, the brackets with clips applied normal forces ranging from a low of 5.6 centi-Newtons (cN) (1 cN = 1 g) to a high of 230 cN. When clearance disappears, the RS increased proportionally with the second-order angle. The 19 x 25-mil stainless steel wires, which were the most stiff, increased at rates between 75 and 84 cN/degree; the 14-mil austenitic nickel-titanium wires, which were the least stiff, increased at rates from 2.6 to 5.4 cN/degree. The treatment objectives for a particular patient at a specific stage should determine the appropriate archwire-bracket combination.
New Insulation Constructions for Aerospace Wiring Applications. Volume 1. Testing and Evaluation
1991-06-01
28 S.3.2 CORONA INCEPTION AND EXTINCIION VOLTAGES 5 - 33 5.3.2.. AC CORONA INCEPTION AND EXTINCTION VOLTAGES 5...... - 33 5.3.2.2 DC CORONA ...SETUP ....... .. 5 - 27 5.10 DIELECTRIC CONSTANT TEST RESULTS .......... .. 5 - 32 5.11 AC CORONA INCEPTION AND EXTINCTION TEST, 22 AWG, 8.6 MIL WALL...AIRFRAME WIRE ... .......... 5 - 39 5.12 AC CORONA INCEPTION AND EXTINCTION TEST, 22 AWG, 5.8 MIL WALL, HOOK UP WIRE .... ........... 5 - 40 5.13 AC
NASA Technical Reports Server (NTRS)
1971-01-01
The reliability of semiconductor devices as influenced by the reliability of wire bonds used in the assembly of the devices is investigated. The specific type of failure dealt with involves fracture of wire bonds as a result of repeated flexure of the wire at the heel of the bond when the devices are operated in an on-off mode. The mechanism of failure is one of induced fracture of the wire. To improve the reliability of a chosen transistor, one-mil diameter wires of aluminum with various alloy additions were studied using an accelerated fatigue testing machine. In addition, the electroprobe was used to study the metallurgy of the wires as to microstructure and kinetics of the growth of insoluble phases. Thermocompression and ultrasonic bonding techniques were also investigated.
Corrosion Preventative Compounds (CPCs) Effect on Aircraft Electrical Wiring Components
2011-08-01
NOTES Focused Workshop on Cadmium Plating Alternatives, August 30-31, 2011, Baltimore, MD. Sponsored by SERDP/ESTCP. 14. ABSTRACT 15. SUBJECT...prepared by the Wiring Interconnections Laboratory of the Raytheon Technical Services Company LLC, Indianapolis, Indiana . Support of this investigation...MIL-DTL-38999 Series III, Class W A Cadmium (over suitable underplate) plated aluminum, silicone grommets and epoxy inserts MIL-DTL-38999 Series
Evaluation of three percent Aqueous Film Forming Foam (AFFF) concentrates as fire fighting agents
NASA Astrophysics Data System (ADS)
Jablonski, E. J.
1981-04-01
A large-scale fire test program involving 20,000-square foot JP-4 fuel fires was conducted to evaluate the fire suppression effectiveness and compatibility of 3 percent Aqueous Film Forming Foam (AFFF) agents in Air Force fire fighting vehicles. Three commercially available 3 percent AFFF concentrates were tested in accordance with military specification MIL-F-24385B. Test results are summarized in Appendix A. As a result of these tests, an updated Revision C to this MIL SPEC has been accomplished with new requirements for both 3 percent and 6 percent AFFF extinguishing agents.
NASA Technical Reports Server (NTRS)
Pryor, R. A.
1980-01-01
Three inch diameter Czochralski silicon substrates sliced directly to 5 mil, 8 mil, and 27 mil thicknesses with wire saw techniques were procured. Processing sequences incorporating either diffusion or ion implantation technologies were employed to produce n+p or n+pp+ solar cell structures. These cells were evaluated for performance, ease of fabrication, and cost effectiveness. It was determined that the use of 7 mil or even 4 mil wafers would provide near term cost reductions for solar cell manufacturers.
NASA Technical Reports Server (NTRS)
1972-01-01
A cost study comparing flat conductor cable (FCC) with small-gage wire (SGW) and conventional round conductor cable (RCC) is presented. This study was based on a vehicle wiring system consisting of 110,000 ft of conventional RCC equally divided between AWG sizes 20,22, and 24 using MIL-W-81044-type wire and MIL-C-26500 circular connectors. Basic cost data were developed on a similar-sized commercial jet airplane wiring system on a previous company R&D program in which advanced wiring techniques were carried through equivalent installations on an airplane mockup; and on data developed on typical average bundles during this program. Various cost elements included were engineering labor, operations (manufacturing) labor, material costs, and cost impact on payload. Engineering labor includes design, wiring system integration, wiring diagrams and cable assembly drawings, wire installations, and other related supporting functions such as the electronic data processing for the wiring. Operations labor includes mockup, tooling and production planning, fabrication, assembly, installation, and quality control cost impact on payload is the conversion of wiring system weight variations through use of different wiring concepts to program payload benefits in terms of dollars.
Impact Study of Synthetic and Alternative Fuel Usage in Army Aircraft Propulsion Systems.
1981-07-01
oil were Included for comparison. The elastomers tested represented all of the non- metallic materials found in aircraft fuel systems. The study on...a Buna N liner (adjacent to the fuel)surrounded by a wire braid and a special butyl-rubber outer hose . These hoses comformed to the following...or Stratoflex Incorporated. The hose usually has a nylon or wire braid on the outside conforming to MIL-C-83291 or MIL-C-83797. Two hose designs are
Precision wire feeder for small diameter wire
Brandon, Eldon D.; Hooper, Frederick M.; Reichenbach, Marvin L.
1992-01-01
A device for feeding small diameter wire having a diameter less than 0.04 mm (16 mil) to a welding station includes a driving wheel for controllably applying a non-deforming driving force to the wire to move the free end of the wire towards the welding station; and a tension device such as a torque motor for constantly applying a reverse force to the wire in opposition to the driving force to keep the wire taut.
Precision wire feeder for small diameter wire
Brandon, E.D.; Hooper, F.M.; Reichenbach, M.L.
1992-08-11
A device for feeding small diameter wire having a diameter less than 0.04 mm (16 mil) to a welding station includes a driving wheel for controllably applying a non-deforming driving force to the wire to move the free end of the wire towards the welding station; and a tension device such as a torque motor for constantly applying a reverse force to the wire in opposition to the driving force to keep the wire taut. 1 figure.
NASA Technical Reports Server (NTRS)
Jellison, J.
1986-01-01
This work is an illustrated handbook containing the rationale and procedure for the evaluation of multilayer printed wiring board construction integrity with respect to plated-through holes in accordance with the requirements of MIL-P-55110D, Printed Wiring Boards. It is intended as a practical aid for those concerned with determining the construction integrity of multilayer boards for high reliability applications. Photomicrographs of cross sectioned holes illustrate defect types, acceptable and unacceptable conditions, and methods of measurement. A procedure for specimen preparation is given, and appropriate paragraphs of the military specification are included and explained.
Flexible Microstrip Circuits for Superconducting Electronics
NASA Technical Reports Server (NTRS)
Chervenak, James; Mateo, Jennette
2013-01-01
Flexible circuits with superconducting wiring atop polyimide thin films are being studied to connect large numbers of wires between stages in cryogenic apparatus with low heat load. The feasibility of a full microstrip process, consisting of two layers of superconducting material separated by a thin dielectric layer on 5 mil (approximately 0.13 mm) Kapton sheets, where manageable residual stress remains in the polyimide film after processing, has been demonstrated. The goal is a 2-mil (approximately 0.051-mm) process using spin-on polyimide to take advantage of the smoother polyimide surface for achieving highquality metal films. Integration of microstrip wiring with this polyimide film may require high-temperature bakes to relax the stress in the polyimide film between metallization steps.
Zhang, Guijiang; Zang, Xiaohuan; Li, Zhi; Wang, Chun; Wang, Zhi
2014-11-01
In this study, polydimethylsiloxane/metal-organic frameworks (PDMS/MOFs), including PDMS/MIL-101 and PDMS/MOF-199, were immobilized onto a stainless steel wire through sol-gel technique as solid-phase microextraction (SPME) fiber coating. The prepared fibers were used for the extraction of some polycyclic aromatic hydrocarbons (PAHs) from water samples prior to gas chromatography-mass spectrometry (GC-MS) analysis. Under the optimized experiment conditions, the PDMS/MIL-101 coated fiber exhibited higher extraction efficiency towards PAHs than that of PDMS/MOF-199. Several parameters affecting the extraction of PAHs by SPME with PDMS/MIL-101 fiber, including the extraction temperature, extraction time, sample volume, salt addition and desorption conditions, were investigated. The limits of detection (LODs) were less than 4.0 ng L(-1) and the linearity was observed in the range from 0.01 to 2.0 µg L(-1) with the correlation coefficients (r) ranging from 0.9940 to 0.9986. The recoveries of the method for the PAHs from water samples at spiking levels of 0.05 and 0.2 µg L(-1) ranged from 78.2% to 110.3%. Single fiber repeatability and fiber-to-fiber reproducibility were less than 9.3% and 13.8%, respectively. Copyright © 2014 Elsevier B.V. All rights reserved.
Development and analysis of insulation constructions for aerospace wiring applications
NASA Astrophysics Data System (ADS)
Slenski, George A.; Woodford, Lynn M.
1993-03-01
The Wright Laboratory Materials Directorate at WPAFB, Ohio recently completed a research and development program under contract with the McDonnell Douglas Aerospace Company, St. Louis, Missouri. Program objectives were to develop wire insulation performance requirements, evaluate candidate insulations, and prepare preliminary specification sheets on the most promising candidates. Aircraft wiring continues to be a high maintenance item and a major contributor to electrically-related aircraft mishaps. Mishap data on aircraft show that chafing of insulation is the most common mode of wire failure. Improved wiring constructions are expected to increase aircraft performance and decrease costs by reducing maintenance actions. In the laboratory program, new insulation constructions were identified that had overall improved performance in evaluation tests when compared to currently available MIL-W-81381 and MIL-W-22759 wiring. These insulations are principally aromatic polyimide and crosslinked ethylene tetrafluoroethylene (ETFE), respectively. Candidate insulations identified in preliminary specification sheets were principally fluoropolymers with a polyimide inner layer. Examples of insulation properties evaluated included flammability, high temperature mechanical and electrical performance, fluid immersion, and susceptibility to arc propagation under applied power chafing conditions. Potential next generation wire insulation materials are also reviewed.
Damage to metallic samples produced by measured lightning currents
NASA Technical Reports Server (NTRS)
Fisher, Richard J.; Schnetzer, George H.
1991-01-01
A total of 10 sample disks of 2024-T3 aluminum and 4130 ferrous steel were exposed to rocket-triggered lightning currents at the Kennedy Space Center test site. The experimental configuration was arranged so that the samples were not exposed to the preliminary streamer, wire-burn, or following currents that are associated with an upward-initiated rocket-triggered flash but which are atypical of naturally initiated lightning. Return-stroke currents and continuing currents actually attaching to the sample were measured, augmented by close-up video recordings of approximately 3 feet of the channel above the sample and by 16-mm movies with 5-ms resolution. From these data it was possible to correlate individual damage spots with streamer, return-stroke, and continuing currents that produced them. Substantial penetration of 80-mil aluminum was produced by a continuing current of submedian amplitude and duration, and full penetration of a 35-mil steel sample occurred under an eightieth percentile continuing current. The primary purpose of the data acquired in these experiments is for use in improving and quantifying the fidelity of laboratory simulations of lightning burnthrough.
Full temperature single event upset characterization of two microprocessor technologies
NASA Technical Reports Server (NTRS)
Nichols, Donald K.; Coss, James R.; Smith, L. S.; Rax, Bernard; Huebner, Mark
1988-01-01
Data for the 9450 I3L bipolar microprocessor and the 80C86 CMOS/epi (vintage 1985) microprocessor are presented, showing single-event soft errors for the full MIL-SPEC temperature range of -55 to 125 C. These data show for the first time that the soft-error cross sections continue to decrease with decreasing temperature at subzero temperatures. The temperature dependence of the two parts, however, is very different.
Code of Federal Regulations, 2011 CFR
2011-07-01
... not less than 1000 mg/ft2 (1.08 mg/cm2) in accordance with military standard specification (mil. spec... shall also be available via the data output port, as specified in table L-1 of section 7.4.19 of this... available to the sampler operator for verification and change and for output via the data output port along...
Analysis of 2004 Round Robin Tests 1 and 4 Data
NASA Technical Reports Server (NTRS)
Hirsch, David; Beeson, Harold
2005-01-01
An analysis of 2004 round robin tests 1 and 4 data is presented. Test 1 burn length test results include: 1) Kydex, WSTF No. 04-38645 25.9% O2 @ 14.3 psia; 2) Kydex, 30% O2 @ 10.2 psia; 3) Royal Blue Cotton, Flame Resistant (WST No. 04-38644) 30% O2 @ 10.2 psia; and 4) Silicone 20.9% O2 @ 14.7 psia. Test 4 burn length test results include: 1) Raychem Electrical Wire, MIL M22759/32-20-9 30% O2 @ 10.2 psia; and 2) Raychem Electrical Wire, MIL M81044/12-20-9 20.9% O2 @ 14.7 psia.
USAF Test Pilot School. Flying Qualities Textbook, Volume 2, Part 1
1986-04-01
Qualities Flight Testing, Performance and Flying Qaulities Branch, Flight Test Engneerd ision, 6510th Test Wing, Air Force Flight Mayst Ce1ter, Edwards...For these aircraft, the program manager may re*uire a mil spec written specifically for the aircraft and control system involwd. 5.20.2 _EL k,Tt...OR MANAGED IN CONTEXT OF MISSION, WITH AVAILABLE PILOT ATTENTION. S UNCONTROLLABLE CONTROL WILL BE LOST DURING SOME PORTION OF MISSION. ACCEPTABLE
1991-03-01
test cases are gathered, studied, and evaluated; industry and other national European programs are studied; and experience is gained. This evolution ...application callable layer. The CGM Generator can be used to record device-independent picture descriptions. conceptually in parallel with the...contributors: I Organization Peter R. Bono Associates, Inc. Secretarial Support Susan Bonde , Diane Bono, E!aine Bono, Brenda Carson, Gillian Hall
Environmental testing and laser transmission results for ruggedized high power IR fiber cables
NASA Astrophysics Data System (ADS)
Busse, Lynda; Kung, Frederic; Florea, Catalin; Shaw, Brandon; Aggarwal, Ishwar; Sanghera, Jas
2013-03-01
We present successful results of high mid-IR laser power transmission as well as MIL-SPEC environmental testing (thermal cycling and vibration testing) of ruggedized, IR-transmitting chalcogenide glass fiber cables. The cables tested included chalcogenide fiber cables with endfaces imprinted with anti-reflective "moth eye" surfaces, whereby the reflection loss is reduced from about 17% per end to less than 3%. The cables with these moth eye surfaces also show excellent laser damage resistance.
Electrical short circuit and current overload tests on aircraft wiring
NASA Technical Reports Server (NTRS)
Cahill, Patricia
1995-01-01
The findings of electrical short circuit and current overload tests performed on commercial aircraft wiring are presented. A series of bench-scale tests were conducted to evaluate circuit breaker response to overcurrent and to determine if the wire showed any visible signs of thermal degradation due to overcurrent. Three types of wire used in commercial aircraft were evaluated: MIL-W-22759/34 (150 C rated), MIL-W-81381/12 (200 C rated), and BMS 1360 (260 C rated). A second series of tests evaluated circuit breaker response to short circuits and ticking faults. These tests were also meant to determine if the three test wires behaved differently under these conditions and if a short circuit or ticking fault could start a fire. It is concluded that circuit breakers provided reliable overcurrent protection. Circuit breakers may not protect wire from ticking faults but can protect wire from direct shorts. These tests indicated that the appearance of a wire subjected to a current that totally degrades the insulation looks identical to a wire subjected to a fire; however the 'fire exposed' conductor was more brittle than the conductor degraded by overcurrent. Preliminary testing indicates that direct short circuits are not likely to start a fire. Preliminary testing indicated that direct short circuits do not erode insulation and conductor to the extent that ticking faults did. Circuit breakers may not safeguard against the ignition of flammable materials by ticking faults. The flammability of materials near ticking faults is far more important than the rating of the wire insulation material.
USAF/WL robust 300 C wire insulation system program status
NASA Technical Reports Server (NTRS)
Wong, Wing
1995-01-01
The objective of this program is to identify, develop, and demonstrate an optimum wire insulation system capable of continuous operation at 300 C which possesses a combination of superior electrical (AC or DC), mechanical, and physical properties over Kapton derived insulations described in MIL-W-81381 and those hybrid materials commonly known as TKT constructions.
USAF/WL robust 300 C wire insulation system program status
NASA Astrophysics Data System (ADS)
Wong, Wing
1995-11-01
The objective of this program is to identify, develop, and demonstrate an optimum wire insulation system capable of continuous operation at 300 C which possesses a combination of superior electrical (AC or DC), mechanical, and physical properties over Kapton derived insulations described in MIL-W-81381 and those hybrid materials commonly known as TKT constructions.
The Performance of Aircraft Control Cables Under Service Conditions
1976-04-01
wires in the cables is illustr;tcd in Ifigs. I ald 2. Fatigue tests were also carried out on samples of galvanised steel cable (5 cwt. (2.49kN) minimumil...sheave ratio using the MIL-C-151I cable of 2.38 mm (3:32 in.) diameter would have been 13.3. For a satisfactory fatigue performance for 7 x 19 galvanised ...critical region in which cable life is relatively low". Reference 13 recommends a sheave ratio of 18 for 7 x 19 galvanised and stainless ,ables and a
Error studies of Halbach Magnets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brooks, S.
2017-03-02
These error studies were done on the Halbach magnets for the CBETA “First Girder” as described in note [CBETA001]. The CBETA magnets have since changed slightly to the lattice in [CBETA009]. However, this is not a large enough change to significantly affect the results here. The QF and BD arc FFAG magnets are considered. For each assumed set of error distributions and each ideal magnet, 100 random magnets with errors are generated. These are then run through an automated version of the iron wire multipole cancellation algorithm. The maximum wire diameter allowed is 0.063” as in the proof-of-principle magnets. Initially,more » 32 wires (2 per Halbach wedge) are tried, then if this does not achieve 1e-4 level accuracy in the simulation, 48 and then 64 wires. By “1e-4 accuracy”, it is meant the FOM defined by √(Σ n≥sextupole a n 2+b n 2) is less than 1 unit, where the multipoles are taken at the maximum nominal beam radius, R=23mm for these magnets. The algorithm initially uses 20 convergence interations. If 64 wires does not achieve 1e-4 accuracy, this is increased to 50 iterations to check for slow converging cases. There are also classifications for magnets that do not achieve 1e-4 but do achieve 1e-3 (FOM ≤ 10 units). This is technically within the spec discussed in the Jan 30, 2017 review; however, there will be errors in practical shimming not dealt with in the simulation, so it is preferable to do much better than the spec in the simulation.« less
Robust 300 C wire insulation system
NASA Technical Reports Server (NTRS)
Nairus, John G.
1994-01-01
The objective of this program is to identify, develop, and demonstrate an optimum wire insulation system that is capable of continuous operation at 300 C. The system is to possess a combination of superior electrical (AC or DC), mechanical, and physical properties over the KAPTON (trademark) derived insulations described in MIL-W-81381 and those hybrid constructions identified in Air Force contract F33615-89-C-5606, commonly known as TKT constructions.
NASA Technical Reports Server (NTRS)
1981-01-01
Presentations of a conference on the use of ruggedized minicomputers are summarized. The following topics are discussed: (1) the role of minicomputers in the development and/or certification of commercial or military airplanes in both the United States and Europe; (2) generalized software error detection techniques; (3) real time software development tools; (4) a redundancy management research tool for aircraft navigation/flight control sensors; (5) extended memory management techniques using a high order language; and (6) some comments on establishing a system maintenance scheme. Copies of presentation slides are also included.
Thermal and vibration testing of ruggedized IR-transmitting fiber cables
NASA Astrophysics Data System (ADS)
Busse, Lynda; Kung, Fred; Florea, Catalin; Shaw, Brandon; Aggarwal, Ishwar; Sanghera, Jas
2013-05-01
We present successful results obtained for thermal/ vibration testing of ruggedized, IR-transmitting chalcogenide glass fiber cables using a government facility with state-of-the-art equipment capable of MIL-SPEC environmental testing. We will also present results of a direct imprinting process to create novel "moth eye" patterned surfaces on the IR fiber cable ends that significantly reduces endface reflection losses from 17% to less than 3%. The cables with these imprinted "moth eye" ends transmit much higher IR laser power without damage than was obtained for previous cables with traditional AR coatings.
Tactical Vehicle Climate Control Testing
2017-03-31
MIL-STD-810G CN1. The greatest care must be taken to monitor this parameter during periods where the vehicle engine is running while in the chamber...a drain plug, wire pass-through, or the gunner’s hatch that can remain closed throughout testing to prevent damaging the cables. Avoid running ...drain plug, wire pass-through, or the gunner’s hatch, that can remain closed throughout testing to prevent damaging the cables. Avoid running cables
46 CFR 160.061-1 - Applicable specifications.
Code of Federal Regulations, 2011 CFR
2011-10-01
...—Iron and steel; sheet, tinned (tin plate). QQ-W-423—Wire, steel, corrosion-resisting HH-P-91—Packing, fiber, hard sheet. CCC-F-451—Flannel, canton. (2) Military specifications: MIL-H-2846—Hooks, fish, steel...
46 CFR 160.061-1 - Applicable specifications.
Code of Federal Regulations, 2010 CFR
2010-10-01
...—Iron and steel; sheet, tinned (tin plate). QQ-W-423—Wire, steel, corrosion-resisting HH-P-91—Packing, fiber, hard sheet. CCC-F-451—Flannel, canton. (2) Military specifications: MIL-H-2846—Hooks, fish, steel...
Characterization of Effluents Given Off by Wiring Insulation
NASA Technical Reports Server (NTRS)
Yost, William T.; Cramer, K. Elliott; Perey, Daniel F.
2003-01-01
When an insulated wire is heated, the insulation emits a variety of effluents. This paper discusses the basis of emissions of effluents from wiring insulation. Several species are emitted at relatively low temperatures, while others are emitted when the wire reaches higher temperatures. We isolate the emissions by relative molecular weight of the effluents and measure the effluent concentration both as a function of time (temperature held constant) and by wire temperature. We find that the Law of Mass Action describes and predicts the time-dependence of the emission of a specific effluent caused by the heating. The binding energy is determined by performing an Arrhenius Plot on the temperature data. These dependencies are discussed and working equations are derived. Data collected from 20 gauge wire (MIL-W-22759/11-20) is used to illustrate and confirm the validity of the theory.
Reference Proteome Extracts for Mass Spec Instrument Performance Validation and Method Development
Rosenblatt, Mike; Urh, Marjeta; Saveliev, Sergei
2014-01-01
Biological samples of high complexity are required to test protein mass spec sample preparation procedures and validate mass spec instrument performance. Total cell protein extracts provide the needed sample complexity. However, to be compatible with mass spec applications, such extracts should meet a number of design requirements: compatibility with LC/MS (free of detergents, etc.)high protein integrity (minimal level of protein degradation and non-biological PTMs)compatibility with common sample preparation methods such as proteolysis, PTM enrichment and mass-tag labelingLot-to-lot reproducibility Here we describe total protein extracts from yeast and human cells that meet the above criteria. Two extract formats have been developed: Intact protein extracts with primary use for sample preparation method development and optimizationPre-digested extracts (peptides) with primary use for instrument validation and performance monitoring
Environmental Influence of Gravity and Pressure on Arc Tracking of Insulated Wires Investigated
NASA Technical Reports Server (NTRS)
2005-01-01
Momentary short-circuit arcs between a defective polyimide-insulated wire and another conductor may thermally char (pyrolize) the insulating material. The charred polyimide, being conductive, can sustain the short-circuit arc, which may propagate along the wire through continuous pyrolization of the polyimide insulation (arc tracking). If the arcing wire is part of a multiple-wire bundle, the polyimide insulation of other wires within the bundle may become thermally charred and start arc tracking also (flash over). Such arc tracking can lead to complete failure of an entire wire bundle, causing other critical spacecraft or aircraft failures. Unfortunately, all tested candidate wire insulations for aerospace vehicles were susceptible to arc tracking. Therefore, a test procedure was designed at the NASA Lewis Research Center to select the insulation type least susceptible to arc tracking. This test procedure addresses the following three areas of concern: (1) probability of initiation, (2) probability of reinitiation (restrike), and (3) extent of arc tracking damage (propagation rate). Item 2 (restrike probability) is an issue if power can be terminated from and reapplied to the arcing wire (by a switch, fuse, or resettable circuit breaker). The degree of damage from an arcing event (item 3) refers to how easily the arc chars nearby insulation and propagates along the wire pair. Ease of nearby insulation charring can be determined by measuring the rate of arc propagation. Insulation that chars easily will propagate the arc faster than insulation that does not char very easily. A popular polyimide insulated wire for aerospace vehicles, MIL-W-81381, was tested to determine a degree of damage from an arcing event (item 3) in the following three environments: (1) microgravity with air at 1-atm pressure, (2) 1g with air at 1 atm, and (3) 1g within a 10^-6 Torr vacuum. The microgravity 1-atm air was the harshest environment, with respect to the rate of damage of arc tracking, for the 20 AWG (American Wiring Gauge) MIL-W-81381 wire insulation type . The vacuum environment resulted in the least damage. Further testing is planned to determine if the environmental results are consistent between insulation types and to evaluate the other two parameters associated with arc tracking susceptibility.
Electronics reliability fracture mechanics. Volume 2: Fracture mechanics
NASA Astrophysics Data System (ADS)
Kallis, J.; Duncan, L.; Buechler, D.; Backes, P.; Sandkulla, D.
1992-05-01
This is the second of two volumes. The other volume (WL-TR-92-3015) is 'Causes of Failures of Shop Replaceable Units and Hybrid Microcircuits.' The objective of the Electronics Reliability Fracture Mechanics (ERFM) program was to develop and demonstrate a life prediction technique for electronic assemblies, when subjected to environmental stresses of vibration and thermal cycling, based upon the mechanical properties of the materials and packaging configurations which make up an electronic system. The application of fracture mechanics to microscale phenomena in electronic assemblies was a pioneering research effort. The small scale made the experiments very difficult; for example, the 1-mil-diameter bond wires in microelectronic devices are 1/3 the diameter of a human hair. A number of issues had to be resolved to determine whether a fracture mechanics modelling approach is correct for the selected failures; specifically, the following two issues had to be resolved: What fraction of the lifetime is spent in crack initiation? Are macro fracture mechanics techniques, used in large structures such as bridges, applicable to the tiny structures in electronic equipment? The following structural failure mechanisms were selected for modelling: bondwire fracture from mechanical cycling; bondwire fracture from thermal (power) cycling; plated through hole (PTH) fracture from thermal cycling. The bondwire fracture test specimens were A1-1 percent Si wires, representative of wires used in the parts in the modules selected for detailed investigation in this program (see Vol. 1 of this report); 1-mil-diameter wires were tested in this program. The PTH test specimens were sections of 14-layer printed wiring boards of the type used.
Electron penetration of spacecraft thermal insulation
NASA Technical Reports Server (NTRS)
Powers, W. L.; Adams, B. F.; Inouye, G. T.
1981-01-01
The external thermal blanket with 13 mils of polyethylene which has the known range and stopping power as a function of electron energy is investiated. The most recent omnidirectional peak Jovian electron flux at 5 Jupiter radii is applied, the electron current penetrating the thermal blanket is calculated and allowed to impinge on a typical 20 mil polyethylene insulator surrounding a wire. The radiation dose rate to the insulator is then calculated and the electrical conductivity found. The results demonstrate that the increased electronic mobility is sufficient to keep the maximum induced electric field two orders of magnitude below the critical breakdown strength.
Evaluation of Wiring Constructions for Space Applications
NASA Technical Reports Server (NTRS)
Hammoud, Ahmad N.; Stavnes, Mark W.; Dickman, John E.; Burkhardt, Linda A.; Woodford, Lynn M.; Ide, James R.; Muegge, ED
1994-01-01
A NASA Office of Safety and Mission Assurance (OS&MA) program to develop lightweight, reliable, and safe wiring insulations for aerospace applications is being performed by the NASA Lewis Research Center (LeRC). As part of this effort, a new wiring construction utilizing high strength PTFE (poly tetrafluoroethylene) as the insulation has been tested and compared with the existing military standard polyimide-based MIL-W-81381 wire construction. Electrical properties which were investigated included ac corona inception and extinction voltages (sea level and 60,000 feet), time/current to smoke, and wire fusing time. The two constructions were also characterized in terms of their mechanical properties of flexural strength, abrasion resistance (23 C and 150 C), and dynamic cut-through (23 C and 200 C). The results obtained in this testing effort are presented and discussed in this paper.
Balliana, Eleonora; Aramendía, Maite; Resano, Martin; Barbante, Carlo; Vanhaecke, Frank
2013-03-01
Although in many cases Pb isotopic analysis can be relied on for provenance determination of ancient bronzes, sometimes the use of "non-traditional" isotopic systems, such as those of Cu and Sn, is required. The work reported on in this paper aimed at revising the methodology for Cu and Sn isotope ratio measurements in archaeological bronzes via optimization of the analytical procedures in terms of sample pre-treatment, measurement protocol, precision, and analytical uncertainty. For Cu isotopic analysis, both Zn and Ni were investigated for their merit as internal standard (IS) relied on for mass bias correction. The use of Ni as IS seems to be the most robust approach as Ni is less prone to contamination, has a lower abundance in bronzes and an ionization potential similar to that of Cu, and provides slightly better reproducibility values when applied to NIST SRM 976 Cu isotopic reference material. The possibility of carrying out direct isotopic analysis without prior Cu isolation (with AG-MP-1 anion exchange resin) was investigated by analysis of CRM IARM 91D bronze reference material, synthetic solutions, and archaeological bronzes. Both procedures (Cu isolation/no Cu isolation) provide similar δ (65)Cu results with similar uncertainty budgets in all cases (±0.02-0.04 per mil in delta units, k = 2, n = 4). Direct isotopic analysis of Cu therefore seems feasible, without evidence of spectral interference or matrix-induced effect on the extent of mass bias. For Sn, a separation protocol relying on TRU-Spec anion exchange resin was optimized, providing a recovery close to 100 % without on-column fractionation. Cu was recovered quantitatively together with the bronze matrix with this isolation protocol. Isotopic analysis of this Cu fraction provides δ (65)Cu results similar to those obtained upon isolation using AG-MP-1 resin. This means that Cu and Sn isotopic analysis of bronze alloys can therefore be carried out after a single chromatographic separation using TRU-Spec resin. Tin isotopic analysis was performed relying on Sb as an internal standard used for mass bias correction. The reproducibility over a period of 1 month (n = 42) for the mass bias-corrected Sn isotope ratios is in the range of 0.06-0.16 per mil (2 s), for all the ratios monitored.
Behroozian, Ahmad; Kachoei, Mojgan; Khatamian, Masumeh; Divband, Baharak
2016-01-01
Background. Any decrease in friction between orthodontic wire and bracket can accelerate tooth movement in the sliding technique and result in better control of anchorage. This study was carried out to evaluate frictional forces by coating orthodontic wires and porcelain brackets with zinc oxide nanoparticles (ZnO). Methods. In this in vitro study, we evaluated a combination of 120 samples of 0.019×0.025 stainless steel (SS) orthodonticwires and 22 mil system edgewise porcelain brackets with and without spherical zinc oxide nanoparticles. Spherical ZnOnanoparticles were deposited on wires and brackets by immersing them in ethanol solution and SEM (scanning electronmicroscope) evaluation confirmed the presence of the ZnO coating. The frictional forces were calculated between the wiresand brackets in four groups: group ZZ (coated wire and bracket), group OO (uncoated wire and bracket), group ZO (coatedwire and uncoated bracket) and group OZ (uncoated wire and coated bracket). Kolmogorov-Smirnov, Mann-Whitney andKruskal-Wallis tests were used for data analysis. Results. The frictional force in ZZ (3.07±0.4 N) was the highest (P <0.05), and OZ (2.18±0.5 N) had the lowest amount of friction (P <0.05) among the groups. There was no significant difference in frictional forces between the ZO and OO groups (2.65±0.2 and 2.70±0.2 N, respectively). Conclusion. Coating of porcelain bracket surfaces with ZnO nanoparticles can decrease friction in the sliding technique,and wire coating combined with bracket coating is not recommended due to its effect on friction. PMID:27429727
Lee, M H; Ahn, H J; Park, J H; Park, Y J; Song, K
2011-02-01
This paper presents a quantitative and rapid method of sequential separation of Pu, (90)Sr and (241)Am nuclides in environmental soil samples with an anion exchange resin and Sr Spec resin. After the sample solution was passed through an anion exchange column connected to a Sr Spec column, Pu isotopes were purified from the anion exchange column. Strontium-90 was separated from other interfering elements by the Sr Spec column. Americium-241 was purified from lanthanides by the anion exchange resin after oxalate co-precipitation. Measurement of Pu and Am isotopes was carried out using an α-spectrometer. Strontium-90 was measured by a low-level liquid scintillation counter. The radiochemical procedure of Pu, (90)Sr and (241)Am nuclides investigated in this study validated by application to IAEA reference materials and environmental soil samples. Copyright © 2010 Elsevier Ltd. All rights reserved.
Simpson, Jr, J A
1950-12-05
A multiple wire counter utilizing air at atmospheric pressure as the ionizing medium and having a window of a nylon sheet of less than 0.5 mil thickness coated with graphite. The window is permeable to alpha particles so that the counter is well adapted to surveying sources of alpha radiation.
Inline Electrical Connector Mate/Demate Pliers
NASA Technical Reports Server (NTRS)
Yutko, Brian; Dininny, Michael; Moscoso, Gerand; Dokos, Adam
2010-01-01
Military and aerospace industries use Mil-Spec type electrical connections on bulkhead panels that require inline access for mate and demate operations. These connectors are usually in tight proximity to other connectors, or recessed within panels. The pliers described here have been designed to work in such tight spaces, and consist of a mirrored set of parallel handles, two cross links, two return springs, and replaceable polyurethane-coated end effectors. The polyurethane eliminates metal-to-metal contact and provides a high-friction surface between the jaw and the connector. Operationally, the user would slide the pliers over the connector shell until the molded polyurethane lip makes contact with the connector shell edge. Then, by squeezing the handles, the end effector jaws grip the connector shell, allowing the connector to be easily disconnected by rotating the pliers. Mating the connector occurs by reversing the prescribed procedure, except the connector shell is placed into the jaws by hand. The molded lip within the jaw allows the user to apply additional force for difficult-to-mate connectors. Handle design has been carefully examined to maximize comfort, limit weight, incorporate tether locations, and improve ergonomics. They have been designed with an off-axis offset for wiring harness clearance, while placing the connector axis of rotation close to the user s axis of wrist rotation. This was done to eliminate fatigue during multiple connector panel servicing. To limit handle opening width, with user ergonomics in mind, the pliers were designed using a parallel jaw mechanism. A cross-link mechanism was used to complete this task, while ensuring smooth operation.
NASA Astrophysics Data System (ADS)
Randau, C.; Brokmeier, H. G.; Gan, W. M.; Hofmann, M.; Voeller, M.; Tekouo, W.; Al-hamdany, N.; Seidl, G.; Schreyer, A.
2015-09-01
The materials science neutron diffractometer STRESS-SPEC located at FRM II is a dedicated instrument for strain and pole figure measurements. Both methods make complementary demands on sample handling. On one hand pole figure measurements need a high degree of freedom to orient small samples and on the other hand in strain investigations it is often necessary to handle large and heavy components. Therefore a robot based sample positioning system was developed, which has the capability to provide both possibilities. Based on this new robot system further developments like a full automated sample changer system for texture measurements were accomplished. Moreover this system opens the door for combined strain and texture analysis at STRESS-SPEC.
Remotely Controlled Mixers for Light Microscopy Module (LMM) Colloid Samples
NASA Technical Reports Server (NTRS)
Kurk, Michael A. (Andy)
2015-01-01
Developed by NASA Glenn Research Center, the LMM aboard the International Space Station (ISS) is enabling multiple biomedical science experiments. Techshot, Inc., has developed a series of colloid specialty cell systems (C-SPECS) for use in the colloid science experiment module on the LMM. These low-volume mixing devices will enable uniform particle density and remotely controlled repetition of LMM colloid experiments. By automating the experiment process, C-SPECS allow colloid samples to be processed more quickly. In addition, C-SPECS will minimize the time the crew will need to spend on colloid experiments as well as eliminate the need for multiple and costly colloid samples, which are expended after a single examination. This high-throughput capability will lead to more efficient and productive use of the LMM. As commercial launch vehicles begin routine visits to the ISS, C-SPECS could become a significant means to process larger quantities of high-value materials for commercial customers.
An application specific integrated circuit based multi-anode microchannel array readout system
NASA Technical Reports Server (NTRS)
Smeins, Larry G.; Stechman, John M.; Cole, Edward H.
1991-01-01
Size reduction of two new multi-anode microchannel array (MAMA) readout systems is described. The systems are based on two analog and one digital application specific integrated circuits (ASICs). The new readout systems reduce volume over previous discrete designs by 80 percent while improving electrical performance on virtually every significant parameter. Emphasis is made on the packaging used to achieve the volume reduction. Surface mount technology (SMT) is combined with modular construction for the analog portion of the readout. SMT reliability concerns and the board area impact of MIL SPEC SMT components is addressed. Package selection for the analog ASIC is discussed. Future sytems will require even denser packaging and the volume reduction progression is shown.
Goodband, Emily L; Serrano, Gonçalo; Constantino-Casas, Fernando; Archer, Joy; Watson, Penny J; Williams, Tim L
2018-01-01
The objectives of this study were fourfold: technical validation of a commercial canine 1,2-o-dilauryl-rac-glycero glutaric acid-(6'-methylresorufin) ester (DGGR) lipase assay, to calculate a reference interval for DGGR lipase by the indirect a posteriori method, to establish biological validity of the assay, and to assess agreement between DGGR lipase and specific canine pancreatic lipase (Spec cPL) assays. Dogs with histologically confirmed acute pancreatitis (n=3), chronic pancreatitis (n=8) and normal pancreatic tissue (n=7) with stored (-80°C) serum samples were identified. Relevant controls were selected. Precision, reproducibility and linearity of DGGR lipase, and the effect of sample haemolysis and freezing, were assessed. Sensitivity and specificity of DGGR lipase and Spec cPL were determined. Agreement between these two parameters was calculated using Cohen's kappa coefficient (κ). The DGGR lipase assay demonstrated excellent precision, reproducibility and linearity. Sample haemolysis and storage at -80°C for 12 months did not influence the assay. DGGR lipase (>245IU/l) and Spec cPL (>400µg/l) both showed poor sensitivity but excellent specificity for acute pancreatitis, and poor to moderate sensitivity but excellent specificity for chronic pancreatitis. Substantial agreement (κ=0.679) was found between DGGR lipase and Spec cPL. The validated DGGR lipase assay had similar sensitivity and specificity for the diagnosis of acute and chronic pancreatitis to Spec cPL. DGGR lipase is a reliable alternative to Spec cPL for the diagnosis of pancreatitis.
Lunar Reconnaissance Orbiter (LRO) Command and Data Handling Flight Electronics Subsystem
NASA Technical Reports Server (NTRS)
Nguyen, Quang; Yuknis, William; Haghani, Noosha; Pursley, Scott; Haddad, Omar
2012-01-01
A document describes a high-performance, modular, and state-of-the-art Command and Data Handling (C&DH) system developed for use on the Lunar Reconnaissance Orbiter (LRO) mission. This system implements a complete hardware C&DH subsystem in a single chassis enclosure that includes a processor card, 48 Gbytes of solid-state recorder memory, data buses including MIL-STD-1553B, custom RS-422, SpaceWire, analog collection, switched power services, and interfaces to the Ka-Band and S-Band RF communications systems. The C&DH team capitalized on extensive experience with hardware and software with PCI bus design, SpaceWire networking, Actel FPGA design, digital flight design techniques, and the use of VxWorks for the real-time operating system. The resulting hardware architecture was implemented to meet the LRO mission requirements. The C&DH comprises an enclosure, a backplane, a low-voltage power converter, a single-board computer, a communications interface board, four data storage boards, a housekeeping and digital input/output board, and an analog data acquisition board. The interfaces between the C&DH and the instruments and avionics are connected through a SpaceWire network, a MIL-STD-1553 bus, and a combination of synchronous and asynchronous serial data transfers over RS-422 and LVDS (low-voltage differential-signaling) electrical interfaces. The C&DH acts as the spacecraft data system with an instrument data manager providing all software and internal bus scheduling, ingestion of science data, distribution of commands, and performing science operations in real time.
Advances in Low Carbon, High Strength Ferrous Alloys
1993-04-01
35 TABLES 1. Specified chemical compositions and mechanical properties for GMAW/SAW/ GTAW wire electrodes, MIL-XXXS type, for welding...minimum service temperature of +300 F. The chromium and molybdenum additions improved hardenability and promoted the formation of mar- tensite in thick...alloying ele- ments ( chromium , nickel and molybdenum) are required, especially for thick sections. Production of high strength steel plate for military
Manufacturing Methods and Technology for Microwave Stripline Circuits
1982-02-26
to the dielectric material so It does not peel during the etching and subsequent processing. The copper cladding requirements were defined by MIL-F...the B-stage,giv- ing acceptable peel strengths per the military requirements. For PTFE sub- strata printed wiring boards that are laminated using a...examining multilayers for measles and delaminations, and analytically by performing peel tests and glass transition temperatures. "STRIPLINE
MIL-100-Fe derived N-doped Fe/Fe3C@C electrocatalysts for efficient oxygen reduction reaction
NASA Astrophysics Data System (ADS)
Guo, Dakai; Han, Sancan; Wang, Jiacheng; Zhu, Yufang
2018-03-01
N-doped porous Fe/Fe3C@C electrocatalysts were prepared by the pyrolysis of the hexamethylenetetramine (HMT)-incorporated MIL-100-Fe at different temperatures (700-1000 °C) under N2 atmosphere. Rotary evaporation of MIL-100-Fe and HMT solution could make more N-enriched HMT molecules enter into the pores of MIL-100-Fe, thus improving nitrogen contents of the final pyrolyzed samples. All pyrolyzed samples show porous textures with middle specific surface areas. The X-ray photoelectron spectroscopy (XPS) results demonstrate the successful introduction of N atoms into carbon framework. Sample Fe-N2-800 prepared by annealing the precursors with the HMT/MIL-100-Fe weight ratio of 2 at 800 °C exhibits the best electrocatalytic activity towards the oxygen reduction reaction (ORR) in terms of onset potential and current density because of high graphitic N and pyridinic N content. The enwrapped Fe/Fe3C nanoparticles and Fe-Nx active sites in these samples could also boost the ORR activity synergistically. Moreover, sample Fe-N2-800 demonstrates a dominant four electron reduction process, as well as excellent long-term operation stability and methanol crossover resistance. Thus, the N-doped Fe/Fe3C@C composites derived from the HMT-incorporated MIL-100-Fe are promising electrocatalysts to replace Pt/C for ORR in practical applications.
Removal of uranium from soil sample digests for ICP-OES analysis of trace metals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Foust, R.D. Jr.; Bidabad, M.
1996-10-01
An analytical procedure has been developed to quantitatively remove uranium from soil sample digests, permitting ICP-OES analysis of trace metals. The procedure involves digesting a soil sample with standard procedures (EPA SW-846, Method 3050), and passing the sample digestate through commercially available resin (U/TEVA{sm_bullet}Spec, Eichrom Industries, Inc.) containing diarryl amylphosphonate as the stationary phase. Quantitative removal of uranium was achieved with soil samples containing up to 60% uranium, and percent recoveries averaged better than 85% for 9 of the 10 metals evaluated (Ag, As, Cd. Cr, Cu, Ni, Pb, Se and Tl). The U/TEVA{sm_bullet}Spec column was regenerated by washing withmore » 200 mL of a 0.01 M oxalic acid/0.02 M nitric acid solution, permitting re-use of the column. GFAAS analysis of a sample spiked with 56.5% uranium, after treatment of the digestate with a U/TEVA{sm_bullet}Spec resin column, resulted in percent recoveries of 97% or better for all target metals.« less
Advanced optical disk storage technology
NASA Technical Reports Server (NTRS)
Haritatos, Fred N.
1996-01-01
There is a growing need within the Air Force for more and better data storage solutions. Rome Laboratory, the Air Force's Center of Excellence for C3I technology, has sponsored the development of a number of operational prototypes to deal with this growing problem. This paper will briefly summarize the various prototype developments with examples of full mil-spec and best commercial practice. These prototypes have successfully operated under severe space, airborne and tactical field environments. From a technical perspective these prototypes have included rewritable optical media ranging from a 5.25-inch diameter format up to the 14-inch diameter disk format. Implementations include an airborne sensor recorder, a deployable optical jukebox and a parallel array of optical disk drives. They include stand-alone peripheral devices to centralized, hierarchical storage management systems for distributed data processing applications.
Lunar Meteorites Miller Range 090034, 090070 and 090075: Composition and Pairing
NASA Astrophysics Data System (ADS)
Martin, D. J. P.; Joy, K. H.
2014-09-01
Three Miller Range meteorites (MIL 34, MIL 70 and MIL 75) were analysed for their compositions and textures. Similarities indicate they are launch paired. Also, they are comparable to Apollo FAN samples so may originate from the lunar nearside.
Huang, Yan-Feng; Liu, Qiao-Huan; Li, Kang; Li, Ying; Chang, Na
2018-03-01
We adopted a facile hydrofluoric acid-free hydro-/solvothermal method for the preparation of four magnetic iron(III)-based framework composites (MIL-101@Fe 3 O 4 -COOH, MIL-101-NH 2 @Fe 3 O 4 -COOH, MIL-53@Fe 3 O 4 -COOH, and MIL-53-NH 2 @Fe 3 O 4 -COOH). The obtained four magnetic iron(III)-based framework composites were applied to magnetic separation and enrichment of the fungicides (prochloraz, myclobutanil, tebuconazole, and iprodione) from environmental samples before high-performance liquid chromatographic analysis. MIL-101-NH 2 @Fe 3 O 4 -COOH showed more remarkable pre-concentration ability for the fungicides as compared to the other three magnetic iron(III)-based framework composites. The extraction parameters affecting enrichment efficiency including extraction time, sample pH, elution time, and the desorption solvent were investigated and optimized. Under the optimized conditions, the standard curve of correlation coefficients were all above 0.991, the limits of detection were 0.04-0.4 μg/L, and the relative standard deviations were below 10.2%. The recoveries of two real water samples ranged from 71.1-99.1% at the low spiking level (30 μg/L). Therefore, the MIL-101-NH 2 @Fe 3 O 4 -COOH composites are attractive for the rapid and efficient extraction of fungicides from environmental water samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Current Welding Consumables Research in the U. S. Navy
1993-03-01
experimental alloy system has a lower C content than the MIL-120S wire and uses no chromium . These modifications are intended to improve resistance to hydrogen...120S system. Molybdemm is reportedly a more potent strengthener than chromium [Enis and Telford, 1%8], but has a less detrimental effect on hydrogen...carbon steel through the control of certain alloying elements such as manganese, chromium , and primarily carbon (Linnert, 1965]. This system can
NASA Technical Reports Server (NTRS)
Park, J.; Nyquist, L. E.; Shih, C.-Y.; Herzog, G. F.; Yamaguchi, A.; Shirai, N.; Ebihara, M.; Lindsay, F. N.; Delaney, J.; Turrin, B.;
2013-01-01
The Kaguya mission detected small but widespread outcrops of nearly pure ferroan anorthosite in and around large impact basins on the Moon. Along with certain lunar rocks, highly feldspathic lunar meteorites such as MIL 090034 (M34), 090036 (M36), and 090070 (M70) may provide samples of this material. We have measured the Ar-40/Ar-39 release patterns and cosmogenic Ar-38 concentrations of several small (<200 microg) samples separated from M34,36, and 70. From petrographic observations concluded that "some of the clasts and grains experienced generations of modifications," a conclusion that we examine in light of our data.
Zelaya, Ian A; Anderson, Jennifer A H; Owen, Micheal D K; Landes, Reid D
2011-03-23
Endogenous shikimic acid determinations are routinely used to assess the efficacy of glyphosate in plants. Numerous analytical methods exist in the public domain for the detection of shikimic acid, yet the most commonly cited comprise spectrophotometric and high-pressure liquid chromatography (HPLC) methods. This paper compares an HPLC and two spectrophotometric methods (Spec 1 and Spec 2) and assesses the effectiveness in the detection of shikimic acid in the tissues of glyphosate-treated plants. Furthermore, the study evaluates the versatility of two acid-based shikimic acid extraction methods and assesses the longevity of plant extract samples under different storage conditions. Finally, Spec 1 and Spec 2 are further characterized with respect to (1) the capacity to discern between shikimic acid and chemically related alicyclic hydroxy acids, (2) the stability of the chromophore (t1/2), (3) the detection limits, and (4) the cost and simplicity of undertaking the analytical procedure. Overall, spectrophotometric methods were more cost-effective and simpler to execute yet provided a narrower detection limit compared to HPLC. All three methods were specific to shikimic acid and detected the compound in the tissues of glyphosate-susceptible crops, increasing exponentially in concentration within 24 h of glyphosate application and plateauing at approximately 72 h. Spec 1 estimated more shikimic acid in identical plant extract samples compared to Spec 2 and, likewise, HPLC detection was more effective than spectrophotometric determinations. Given the unprecedented global adoption of glyphosate-resistant crops and concomitant use of glyphosate, an effective and accurate assessment of glyphosate efficacy is important. Endogenous shikimic acid determinations are instrumental in corroborating the efficacy of glyphosate and therefore have numerous applications in herbicide research and related areas of science as well as resolving many commercial issues as a consequence of glyphosate utilization.
NASA Astrophysics Data System (ADS)
Hallis, L. J.
2013-02-01
The weathering products present in igneous terrestrial Antarctic samples were analyzed, and compared with those found in the four Miller Range nakhlite Martian meteorites. The aim of these comparisons was to determine which of the alteration phases in the Miller Range nakhlites are produced by terrestrial weathering, and what effect rock composition has on these phases. Antarctic terrestrial samples MIL 05031 and EET 96400, along with the Miller Range nakhlites MIL 03346 and 090032, were found to contain secondary alteration assemblages at their externally exposed surfaces. Despite the difference in primary mineralogy, the assemblages of these rocks consist mostly of sulfates (jarosite in MIL 05031, jarosite and gypsum in EET 96400) and iddingsite-like Fe-clay. As neither of the terrestrial samples contains sulfur-bearing primary minerals, and these minerals are rare in the Miller Range nakhlites, it appears that SO42-, possibly along with some of the Na+, K+, and Ca+ in these phases, was sourced from wind-blown sea spray and biogenic emissions from the southern ocean. Cl enrichment in the terrestrially derived "iddingsite" of MIL 05031 and MIL 03346, and the presence of halite at the exterior edge of MIL 090032, can also be explained by this process. However, jarosite within and around the olivine-bound melt inclusions of MIL 090136 is present in the interior of the meteorite and, therefore, is probably the product of preterrestrial weathering on Mars.
Hydrocarbon-fuel/combustion-chamber-liner materials compatibility
NASA Technical Reports Server (NTRS)
Gage, Mark L.
1990-01-01
Results of material compatibility experiments using hydrocarbon fuels in contact with copper-based combustion chamber liner materials are presented. Mil-Spec RP-1, n- dodecane, propane, and methane fuels were tested in contact with OFHC, NASA-Z, and ZrCu coppers. Two distinct test methods were employed. Static tests, in which copper coupons were exposed to fuel for long durations at constant temperature and pressure, provided compatibility data in a precisely controlled environment. Dynamic tests, using the Aerojet Carbothermal Test Facility, provided fuel and copper compatibility data under realistic booster engine service conditions. Tests were conducted using very pure grades of each fuel and fuels to which a contaminant, e.g., ethylene or methyl mercaptan, was added to define the role played by fuel impurities. Conclusions are reached as to degradation mechanisms and effects, methods for the elimination of these mechanisms, selection of copper alloy combustion chamber liners, and hydrocarbon fuel purchase specifications.
Problems with aging wiring in Naval aircraft
NASA Technical Reports Server (NTRS)
Campbell, Frank J.
1994-01-01
The Navy is experiencing a severe aircraft electrical wiring maintenance problem as a result of the extensive use of an aromatic polyimide insulation that is deteriorating at a rate that was unexpected when this wire was initially selected. This problem has significantly affected readiness, reliability, and safety and has greatly increased the cost of ownership of Naval aircraft. Failures in wire harnesses have exhibited arcing and burning that will propagate drastically, to the interruption of many electrical circuits from a fault initiated by the failure of deteriorating wires. There is an urgent need for a capability to schedule aircraft rewiring in an orderly manner with a logically derived determination of which aircraft have aged to the point of absolute necessity. Excessive maintenance was demonstrated to result from the accelerated aging due to the parameters of moisture, temperature, and strain that exist in the Naval Aircraft environment. Laboratory studies have demonstrated that MIL-W-81381 wire insulation when aged at high humidities followed the classical Arrhenius thermal aging relationship. In an extension of the project a multifactor formula was developed that is now capable of predicting life under varying conditions of these service parameters. An automated test system has also been developed to analyze the degree of deterioration that has occurred in wires taken from an aircraft in order to obtain an assessment of remaining life. Since it is both physically and financially impossible to replace the wiring in all the Navy's aircraft at once, this system will permit expedient scheduling so that those aircraft that are most probable to have wiring failure problems can be overhauled first.
Photometric classification and redshift estimation of LSST Supernovae
NASA Astrophysics Data System (ADS)
Dai, Mi; Kuhlmann, Steve; Wang, Yun; Kovacs, Eve
2018-07-01
Supernova (SN) classification and redshift estimation using photometric data only have become very important for the Large Synoptic Survey Telescope (LSST), given the large number of SNe that LSST will observe and the impossibility of spectroscopically following up all the SNe. We investigate the performance of an SN classifier that uses SN colours to classify LSST SNe with the Random Forest classification algorithm. Our classifier results in an area-under-the-curve of 0.98 which represents excellent classification. We are able to obtain a photometric SN sample containing 99 per cent SNe Ia by choosing a probability threshold. We estimate the photometric redshifts (photo-z) of SNe in our sample by fitting the SN light curves using the SALT2 model with nested sampling. We obtain a mean bias (⟨zphot - zspec⟩) of 0.012 with σ (z_phot-z_spec/1+z_spec) = 0.0294 without using a host-galaxy photo-z prior, and a mean bias (⟨zphot - zspec⟩) of 0.0017 with σ (z_phot-z_spec/1+z_spec) = 0.0116 using a host-galaxy photo-z prior. Assuming a flat ΛCDM model with Ωm = 0.3, we obtain Ωm of 0.305 ± 0.008 (statistical errors only), using the simulated LSST sample of photometric SNe Ia (with intrinsic scatter σint = 0.11) derived using our methodology without using host-galaxy photo-z prior. Our method will help boost the power of SNe from the LSST as cosmological probes.
Xie, Lijun; Liu, Shuqin; Han, Zhubing; Jiang, Ruifen; Zhu, Fang; Xu, Weiqin; Su, Chengyong; Ouyang, Gangfeng
2017-09-01
The fiber coating is the key part of the solid-phase microextraction (SPME) technique, and it determines the sensitivity, selectivity, and repeatability of the analytical method. In this work, amine (NH 2 )-functionalized material of Institute Lavoisier (MIL)-53(Al) nanoparticles were successfully synthesized, characterized, and applied as the SPME fiber coating for efficient sample pretreatment owing to their unique structures and excellent adsorption properties. Under optimized conditions, the NH 2 -MIL-53(Al)-coated fiber showed good precision, low limits of detection (LODs) [0.025-0.83 ng L -1 for synthetic musks (SMs) and 0.051-0.97 ng L -1 for organochlorine pesticides (OCPs)], and good linearity. Experimental results showed that the NH 2 -MIL-53(Al) SPME coating was solvent resistant and thermostable. In addition, the extraction efficiencies of the NH 2 -MIL-53(Al) coating for SMs and OCPs were higher than those of commercially available SPME fiber coatings such as polydimethylsiloxane, polydimethylsiloxane-divinylbenzene, and polyacrylate. The reasons may be that the analytes are adsorbed on NH 2 -MIL-53(Al) primarily through π-π interactions, electron donor-electron acceptor interactions, and hydrogen bonds between the analytes and organic linkers of the material. Direct immersion (DI) SPME-gas chromatography-mass spectrometry methods based on NH 2 -MIL-53(Al) were successfully applied for the analysis of tap and river water samples. The recoveries were 80.3-115% for SMs and 77.4-117% for OCPs. These results indicate that the NH 2 -MIL-53(Al) coating may be a promising alternative to SPME coatings for the enrichment of SMs and OCPs.
The special radiation-hardened processors for new highly informative experiments in space
NASA Astrophysics Data System (ADS)
Serdin, O. V.; Antonov, A. A.; Dubrovsky, A. G.; Novogilov, E. A.; Zuev, A. L.
2017-01-01
The article provides a detailed description of the series of special radiation-hardened microprocessor developed by SRISA for use in space technology. The microprocessors have 32-bit and 64-bit KOMDIV architecture with embedded SpaceWire, RapidIO, Ethernet and MIL-STD-1553B interfaces. These devices are used in space telescope GAMMA-400 data acquisition system, and may also be applied to other experiments in space (such as observatory “Millimetron” etc.).
A method for identifying EMI critical circuits during development of a large C3
NASA Astrophysics Data System (ADS)
Barr, Douglas H.
The circuit analysis methods and process Boeing Aerospace used on a large, ground-based military command, control, and communications (C3) system are described. This analysis was designed to help identify electromagnetic interference (EMI) critical circuits. The methodology used the MIL-E-6051 equipment criticality categories as the basis for defining critical circuits, relational database technology to help sort through and account for all of the approximately 5000 system signal cables, and Macintosh Plus personal computers to predict critical circuits based on safety margin analysis. The EMI circuit analysis process systematically examined all system circuits to identify which ones were likely to be EMI critical. The process used two separate, sequential safety margin analyses to identify critical circuits (conservative safety margin analysis, and detailed safety margin analysis). These analyses used field-to-wire and wire-to-wire coupling models using both worst-case and detailed circuit parameters (physical and electrical) to predict circuit safety margins. This process identified the predicted critical circuits that could then be verified by test.
Ma, Ruiyang; Hao, Lin; Wang, Junmin; Wang, Chun; Wu, Qiuhua; Wang, Zhi
2016-09-01
An iron-embedded porous carbon material (MIL-53-C) was fabricated by the direct carbonization of MIL-53. The MIL-53-C possesses a high surface area and good magnetic behavior. The structure, morphology, magnetic property, and porosity of the MIL-53-C were studied by scanning electron microscopy, transmission electron microscopy, vibrating sample magnetometry, and N2 adsorption. With the use of MIL-53-C as the magnetic solid-phase extraction adsorbent, a simple and efficient method was developed for the magnetic solid-phase extraction of three hormones from water and human urine samples before high-performance liquid chromatography with UV detection. The developed method exhibits a good linear response in the range of 0.02-100 ng/mL for water and 0.5-100 ng/mL for human urine samples, respectively. The limit of detection (S/N = 3) for the analytes was 0.005-0.01 ng/mL for water sample and 0.1-0.3 ng/mL for human urine sample. The limit of quantification (S/N = 10) of the analytes were in the range of 0.015-0.030 and 0.3-0.9 ng/mL, respectively. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Jia, Xiuna; Zhao, Pan; Ye, Xiu; Zhang, Lianjun; Wang, Ting; Chen, Qinyu; Hou, Xiaohong
2017-07-01
As a novel material, metal-organic framework/graphite oxide (MIL-101(Cr)@GO) has great potential for the pretreatment of trace analytes. In the present study, MIL-101(Cr)@GO was synthesized using a solvothermal synthesis method at the nanoscale and was applied as sorbent in the dispersive micro-solid phase extraction (DMSPE) for the enrichment of the trace sulfonamides (SAs) from milk samples for the first time. Several experimental parameters including kinds of sorbents, the effect of pH, the amount of MIL-101(Cr)@GO, ionic strength, adsorption time, desorption solvent and desorption time were investigated. Under the optimal conditions, the linear ranges were from 0.1 to 10μg/L, 0.2-20μg/L or 0.5-50μg/L for the analytes with regression coefficients (r) from 0.9942 to 0.9999. The limits of detection were between 0.012 and 0.145μg/L. The recoveries ranged from 79.83% to 103.8% with relative standard deviations (RSDs)<10% (n=3). MIL-101(Cr)@GO exhibited remarkable advantages compared to MIL-101(Cr), MIL-100(Fe), activated carbon and other sorbent materials used in pretreatment methods. A simple, rapid, sensitive, inexpensive and less solvent consuming method of DMSPE-ultra-high performance liquid chromatography-tandem mass spectrometry (DMSPE-UHPLC-MS/MS) was successfully applied to the pre-concentration and determination of twelve SAs in milk samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Cuyler, Erin E; Byrne, Robert H
2018-08-22
A simple protocol was developed to measure seawater calcium carbonate saturation states (Ω spec ) spectrophotometrically. Saturation states are typically derived from the separate measurement of two other carbon system parameters, with each requiring unique instrumentation and often complex measurement protocols. Using the new protocol, the only required equipment is a thermostatted laboratory spectrophotometer. For each seawater sample, spectrophotometric measurements of pH (visible absorbance) are made in paired optical cells, one with and one without added nitric acid. Ultraviolet absorbance is measured to determine the amount of added acid based on the direct proportionality between nitrate concentration and UV absorbance. Coupled measurements of pH and the alkalinity change that accompanies the nitric acid addition allow calculation of a seawater sample's original carbonate ion concentration and saturation state. These paired absorbance measurements yield Ω spec (and other carbonate system parameters), with each sample requiring about 12 min processing time. Initially, an instrument-specific nitrate molar absorptivity coefficient must be determined (due to small but significant discrepancies in instrumental wavelength calibrations), but thereafter no further calibration is needed. In this work, the 1σ precision of replicate measurements of aragonite saturation state was found to be 0.020, and the average difference between Ω spec and Ω calculated conventionally from measured total alkalinity and pH (Ω calc ) was -0.11% ± 0.96% (a level of accuracy comparable to that obtained from spectrophotometric measurements of carbonate ion concentration). Over the entire range of experimental conditions, 0.97 < Ω < 3.17 (n = 125), all measurements attained the Global Ocean Acidification Observing Network's "weather level" goal for accuracy and 90% attained the more stringent "climate level" goal. When Ω spec was calculated from averages of duplicate samples (n = 56), the precision improved to 0.014 and the average difference between Ω spec and Ω calc improved to -0.11% ± 0.73%. Additionally, 97% of the duplicate-based Ω spec measurements attained the "climate level" accuracy goal. These results indicate that the simple measurement protocol developed in this work should be widely applicable for monitoring fundamental seawater changes associated with ocean acidification. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Sriskantharajah, S.; Cutting, S.; Lowry, D.; Grassineau, N.; Nisbet, E.
2003-04-01
Methane emissions from landfills are an important source of European greenhouse emissions, and could be reduced by a biological management program that used methanotrophs in landfill cover soils. Topsoil samples taken from a London Landfill were incubated on Nitrate Mineral Salts medium in the presence of methane. The resulting colonies were probed for methanotrophic DNA using PCR amplification. DNA from methanotroph positive colonies was cloned and sequenced for identification. Isolates belonging to the genera Methylocaldum, Methylomonas and Methylosinus were detected. Phylogenetic analysis suggests the presence of possible new species. In addition dried samples of the isolates were analysed for their stable carbon isotope (δ 13C) composition. The results were δ 13C values of -27 per mil and -25 per mil for Methylomonas isolates, -35 per mil and -44 per mil for Methylosinus isolates, -58 per mil and -60 per mil for some of the Methylocaldum isolates and -35 per mil and -45 per mil for the others. This isotopic variation is reflected in a phylogenetic tree of the isolates. The differences shown in the δ 13C analysis could be due to differing biochemical properties, and if the technique is further developed, it may be used for rapid identification of bacteria useful in landfill management for reducing methane emissions. The results suggest that useful reductions in methane emissions could be achieved by a careful design of landfill cover to culture methanotrophs.
Point-of-care device to diagnose and monitor neonatal jaundice in low-resource settings
Keahey, Pelham A.; Simeral, Mathieu L.; Schroder, Kristofer J.; Bond, Meaghan M.; Mtenthaonnga, Prince J.; Miros, Robert H.; Dube, Queen
2017-01-01
Newborns are at increased risk of jaundice, a condition in which excess bilirubin accumulates in blood. Left untreated, jaundice can lead to neurological impairment and death. Jaundice resulting from unconjugated hyperbilirubinemia is easily treated with exposure to blue light, and phototherapy systems have been developed for low-resource settings; however, there are no appropriate solutions to diagnose and monitor jaundice in these settings. To address this need we present BiliSpec, a low-cost reader and disposable lateral flow card designed to measure the concentration of total bilirubin from several drops of blood at the point of care. We evaluated the performance of BiliSpec, using blood from normal volunteers spiked with varying amounts of bilirubin; results measured using BiliSpec correlated well with a reference laboratory bilirubinometer (r = 0.996). We then performed a pilot clinical study using BiliSpec to measure total bilirubin in neonates at risk for jaundice at Queen Elizabeth Central Hospital in Blantyre, Malawi. Concentrations measured using BiliSpec correlated well with those measured using a laboratory reference standard in 94 patient samples ranging from 1.1 mg/dL to 23.0 mg/dL in concentration (r = 0.973). The mean difference between bilirubin levels measured with BiliSpec and the reference standard was 0.3 mg/dL (95% CI: −1.7–2.2 mg/dL). PMID:29203650
Photometric classification and redshift estimation of LSST Supernovae
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dai, Mi; Kuhlmann, Steve; Wang, Yun
Supernova (SN) classification and redshift estimation using photometric data only have become very important for the Large Synoptic Survey Telescope (LSST), given the large number of SNe that LSST will observe and the impossibility of spectroscopically following up all the SNe. We investigate the performance of an SN classifier that uses SN colours to classify LSST SNe with the Random Forest classification algorithm. Our classifier results in an area-under-the-curve of 0.98 which represents excellent classification. We are able to obtain a photometric SN sample containing 99 percent SNe Ia by choosing a probability threshold. We estimate the photometric redshifts (photo-z)more » of SNe in our sample by fitting the SN light curves using the SALT2 model with nested sampling. We obtain a mean bias (⟨zphot - zspec⟩) of 0.012 with σ(z phot -z spec 1+z spec )=0.0294 σ(zphot-zspec1+zspec)=0.0294 without using a host-galaxy photo-z prior, and a mean bias (⟨zphot - zspec⟩) of 0.0017 with σ(z phot -z spec 1+z spec )=0.0116 σ(zphot-zspec1+zspec)=0.0116 using a host-galaxy photo-z prior. Assuming a flat ΛCDM model with Ωm = 0.3, we obtain Ωm of 0.305 ± 0.008 (statistical errors only), using the simulated LSST sample of photometric SNe Ia (with intrinsic scatter σint = 0.11) derived using our methodology without using host-galaxy photo-z prior. Our method will help boost the power of SNe from the LSST as cosmological probes.« less
Liu, Yue; Hu, Jia; Li, Yan; Shang, Yun-Tao; Wang, Jia-Qi; Zhang, Ye; Wang, Zhong-Liang
2017-10-01
In this work, a CE method was developed to separate five anthraquinones: aloe-emodin, rhein, emodin, chrysophanol, and physcion. The CE method used a nano-sized metal organic framework MIL-101 (nMIL-101) as pseudostationary phase (PSP) and sorbent for dispersed particle extraction (DPE). The nMIL-101 was synthesized by microwave technique and was characterized by UV-vis, TEM, Zeta potential, X-ray diffraction spectrometry and micropore physisorption. In this method, anthraquinones were adsorbed by nMIL-101 of a fast kinetics within 10 min and then separated by CE. The CE conditions were optimized considering time, pH, buffer ionic strength, and nanoparticles concentration. The optimal CE condition is using 20 mM sodium borate buffer (pH 9.1) containing 15% methanol (v/v) and 400 mg/L nMIL-101 as additives within 8 min. The LODs varied from 24 to 57 μg/L, which were lower than those previously reported. Our method has been successfully applied to determine trace anthraquinones in environmental water samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Texture analysis at neutron diffractometer STRESS-SPEC
NASA Astrophysics Data System (ADS)
Brokmeier, H.-G.; Gan, W. M.; Randau, C.; Völler, M.; Rebelo-Kornmeier, J.; Hofmann, M.
2011-06-01
In response to the development of new materials and the application of materials and components in advanced technologies, non-destructive measurement methods of textures and residual stresses have gained worldwide significance in recent years. The materials science neutron diffractometer STRESS-SPEC at FRM II (Garching, Germany) is designed to be applied equally to texture and residual stress analyses by virtue of its very flexible configuration. Due to the high penetration capabilities of neutrons and the high neutron flux of STRESS-SPEC it allows a combined analysis of global texture, local texture, strain pole figure and FWHM pole figure in a wide variety of materials including metals, alloys, composites, ceramics and geological materials. Especially, the analysis of texture gradients in bulk materials using neutron diffraction has advantages over laboratory X-rays and EBSD for many scientific cases. Moreover, neutron diffraction is favourable for coarse-grained materials, where bulk information averaged over texture inhomogeneities is needed, and also stands out due to easy sample preparation. In future, the newly developed robot system for STRESS-SPEC will allow much more flexibility than an Eulerian cradle as on standard instruments. Five recent measurements are shown to demonstrate the wide range of possible texture applications at STRESS-SPEC diffractometer.
Trujillo-Rodríguez, María J; Nacham, Omprakash; Clark, Kevin D; Pino, Verónica; Anderson, Jared L; Ayala, Juan H; Afonso, Ana M
2016-08-31
This work describes the applicability of magnetic ionic liquids (MILs) in the analytical determination of a group of heavy polycyclic aromatic hydrocarbons. Three different MILs, namely, benzyltrioctylammonium bromotrichloroferrate (III) (MIL A), methoxybenzyltrioctylammonium bromotrichloroferrate (III) (MIL B), and 1,12-di(3-benzylbenzimidazolium) dodecane bis[(trifluoromethyl)sulfonyl)]imide bromotrichloroferrate (III) (MIL C), were designed to exhibit hydrophobic properties, and their performance examined in a microextraction method for hydrophobic analytes. The magnet-assisted approach with these MILs was performed in combination with high performance liquid chromatography and fluorescence detection. The study of the extraction performance showed that MIL A was the most suitable solvent for the extraction of polycyclic aromatic hydrocarbons and under optimum conditions the fast extraction step required ∼20 μL of MIL A for 10 mL of aqueous sample, 24 mmol L(-1) NaOH, high ionic strength content of NaCl (25% (w/v)), 500 μL of acetone as dispersive solvent, and 5 min of vortex. The desorption step required the aid of an external magnetic field with a strong NdFeB magnet (the separation requires few seconds), two back-extraction steps for polycyclic aromatic hydrocarbons retained in the MIL droplet with n-hexane, evaporation and reconstitution with acetonitrile. The overall method presented limits of detection down to 5 ng L(-1), relative recoveries ranging from 91.5 to 119%, and inter-day reproducibility values (expressed as relative standard derivation) lower than 16.4% for a spiked level of 0.4 μg L(-1) (n = 9). The method was also applied for the analysis of real samples, including tap water, wastewater, and tea infusion. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Goodrich, Cyrena Anne; Kita, Noriko T.; Sutton, Stephen R.; Wirick, Sue; Gross, Juliane
2017-05-01
Miller Range (MIL) 090340 and MIL 090206 are olivine-rich achondrites originally classified as ureilites. We investigate their petrography, mineral compositions, olivine Cr valences, equilibration temperatures, and (for MIL 090340) oxygen isotope compositions, and compare them with ureilites and other olivine-rich achondrites. We conclude that they are brachinite-like achondrites that provide new insights into the petrogenesis of brachinite clan meteorites. MIL 090340,6 has a granoblastic texture and consists of 97 modal % by area olivine (Fo = molar Mg/[Mg+Fe] = 71.3 ± 0.6). It also contains minor to trace augite, chromite, chlorapatite, orthopyroxene, metal, troilite, and terrestrial Fe-oxides. Approximately 80% by area of MIL 090206,5 has a granoblastic texture of olivine (Fo 72.3 ± 0.1) plus minor augite and chromite, similar to MIL 090340 but also containing minor plagioclase. The rest of the section consists of a single crystal of orthopyroxene ( 11 × 3 mm), poikilitically enclosing rounded grains of olivine (Fo = 76.1 ± 0.6), augite, chromite, metal, and sulfide. Equilibration temperatures for MIL 090340 and MIL 090206, calculated from olivine-spinel, olivine-augite, and two-pyroxene thermometry range from 800 to 930 °C. In both samples, symplectic intergrowths of Ca-poor orthopyroxene + opaque phases (Fe-oxides, sulfide, metal) occur as rims on and veins/patches within olivine. Before terrestrial weathering, the opaques were probably mostly sulfide, with minor metal. All petrologic properties of MIL 090340 and MIL 090206 are consistent with those of brachinite clan meteorites, and largely distinct from those of ureilites. Oxygen isotope compositions of olivine in MIL 090340 (δ18O = 5.08 ± 0.30‰, δ17O = 2.44 ± 0.21‰, and Δ17O = -0.20 ± 0.12‰) are also within the range of brachinite clan meteorites, and well distinguished from ureilites. Olivine Cr valences in MIL 090340 and the granoblastic area of MIL 090206 are 2.57 ± 0.06 and 2.59 ± 0.07, respectively, similar to those of three brachinites also analyzed here (Brachina, Hughes 026, Nova 003). They are higher than those of olivine in ureilites, even those containing chromite. The valence systematics of MIL 090340, MIL 090206, and the three analyzed brachinites (lower Fo = more oxidized Cr) are consistent with previous evidence that brachinite-like parent bodies were inherently more oxidized than the ureilite parent body. The symplectic orthopyroxene + sulfide/metal assemblages in MIL 090340, MIL 090206, and many brachinite clan meteorites have superficial similarities to characteristic "reduction rims" in ureilites. However, they differ significantly in detail. They likely formed by reaction of olivine with S-rich fluids, with only minor reduction. MIL 090340 and the granoblastic area of MIL 090206 are similar in modal mineralogy and texture to most brachinites, but have higher Fo values typical of brachinite-like achondrites. The poikilitic pyroxene area of MIL 090206 is more typical of brachinite-like achondrites. The majority of their properties suggest that MIL 090340 and MIL 090206 are residues of low-degree partial melting. The poikilitic area of MIL 090206 could be a result of limited melt migration, with trapping and recrystallization of a small volume of melt in the residual matrix. These two samples are so similar in mineral compositions, Cr valence, and cosmic ray exposure ages that they could be derived from the same lithologic unit on a common parent body.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goodrich, Cyrena Anne; Kita, Noriko T.; Sutton, Stephen R.
2017-05-01
Miller Range (MIL) 090340 and MIL 090206 are olivine-rich achondrites originally classified as ureilites. We investigate their petrography, mineral compositions, olivine Cr valences, equilibration temperatures, and (for MIL 090340) oxygen isotope compositions, and compare them with ureilites and other olivine-rich achondrites. We conclude that they are brachinite-like achondrites that provide new insights into the petrogenesis of brachinite clan meteorites. MIL 090340,6 has a granoblastic texture and consists of ~97 modal % by area olivine (Fo = molar Mg/[Mg+Fe] = 71.3 ± 0.6). It also contains minor to trace augite, chromite, chlorapatite, orthopyroxene, metal, troilite, and terrestrial Fe-oxides. Approximately 80% bymore » area of MIL 090206,5 has a granoblastic texture of olivine (Fo 72.3 ± 0.1) plus minor augite and chromite, similar to MIL 090340 but also containing minor plagioclase. The rest of the section consists of a single crystal of orthopyroxene (~11 × 3 mm), poikilitically enclosing rounded grains of olivine (Fo = 76.1 ± 0.6), augite, chromite, metal, and sulfide. Equilibration temperatures for MIL 090340 and MIL 090206, calculated from olivine-spinel, olivine-augite, and two-pyroxene thermometry range from ~800 to 930 °C. In both samples, symplectic intergrowths of Ca-poor orthopyroxene + opaque phases (Fe-oxides, sulfide, metal) occur as rims on and veins/patches within olivine. Before terrestrial weathering, the opaques were probably mostly sulfide, with minor metal. All petrologic properties of MIL 090340 and MIL 090206 are consistent with those of brachinite clan meteorites, and largely distinct from those of ureilites. Oxygen isotope compositions of olivine in MIL 090340 (δ18O = 5.08 ± 0.30‰, δ17O = 2.44 ± 0.21%, and Δ17O = -0.20 ± 0.12‰) are also within the range of brachinite clan meteorites, and well distinguished from ureilites. Olivine Cr valences in MIL 090340 and the granoblastic area of MIL 090206 are 2.57 ± 0.06 and 2.59 ± 0.07, respectively, similar to those of three brachinites also analyzed here (Brachina, Hughes 026, Nova 003). They are higher than those of olivine in ureilites, even those containing chromite. The valence systematics of MIL 090340, MIL 090206, and the three analyzed brachinites (lower Fo = more oxidized Cr) are consistent with previous evidence that brachinite-like parent bodies were inherently more oxidized than the ureilite parent body. The symplectic orthopyroxene + sulfide/metal assemblages in MIL 090340, MIL 090206, and many brachinite clan meteorites have superficial similarities to characteristic “reduction rims” in ureilites. However, they differ significantly in detail. They likely formed by reaction of olivine with S-rich fluids, with only minor reduction. MIL 090340 and the granoblastic area of MIL 090206 are similar in modal mineralogy and texture to most brachinites, but have higher Fo values typical of brachinite-like achondrites. The poikilitic pyroxene area of MIL 090206 is more typical of brachinite-like achondrites. The majority of their properties suggest that MIL 090340 and MIL 090206 are residues of low-degree partial melting. The poikilitic area of MIL 090206 could be a result of limited melt migration, with trapping and recrystallization of a small volume of melt in the residual matrix. These two samples are so similar in mineral compositions, Cr valence, and cosmic ray exposure ages that they could be derived from the same lithologic unit on a common parent body.« less
Liu, Yue; Hu, Jia; Li, Yan; Li, Xiao-Shuang; Wang, Zhong-Liang
2016-10-01
A novel method with high sensitivity for the rapid determination of chrysin, apigenin and luteolin in environment water samples was developed by double-pumps controlled on-line solid-phase extraction (SPE) coupled with high-performance liquid chromatography (HPLC). In the developed technique, metal organic framework MIL-101 was synthesized and applied as a sorbent for SPE. The as-synthesized MIL-101 was characterized by scanning electron microscope, X-ray diffraction spectrometry, thermal gravimetric analysis and micropore physisorption analysis. The MIL-101 behaved as a fast kinetics in the adsorption of chrysin, apigenin and luteolin. On-line SPE of chrysin, apigenin and luteolin was processed by loading a sample solution at a flow rate of 1.0 mL/min for 10 min. The extracted analytes were subsequently eluted into a ZORBAX Bonus-RP analytical column (25 cm long × 4.6 mm i.d.) for HPLC separation under isocratic condition with a mobile phase (MeOH: ACN: 0.02 M H 3 PO 4 = 35:35:30) at a flow rate of 1.0 mL/min. Experimental conditions, including ionic strength, sample pH, sample loading rates, sample loading time and desorption analytes time, were further optimized to obtain efficient preconcentration and high-precision determination of the analytes mentioned above. The method achieved the merits of simplicity, rapidity, sensitivity, wide linear range and high sample throughput. The possible mechanism for the adsorption of flavonoids on MIL-101 was proposed. The developed method has been applied to determine trace chrysin, apigenin and luteolin in a variety of environmental water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Chisvert, Alberto; Benedé, Juan L; Anderson, Jared L; Pierson, Stephen A; Salvador, Amparo
2017-08-29
With the aim of contributing to the development and improvement of microextraction techniques, a novel approach combining the principles and advantages of stir bar sorptive extraction (SBSE) and dispersive liquid-liquid microextraction (DLLME) is presented. This new approach, termed stir bar dispersive liquid microextraction (SBDLME), involves the addition of a magnetic ionic liquid (MIL) and a neodymium-core magnetic stir bar into the sample allowing the MIL coat the stir bar due to physical forces (i.e., magnetism). As long as the stirring rate is maintained at low speed, the MIL resists rotational (centrifugal) forces and remains on the stir bar surface in a manner closely resembling SBSE. By increasing the stirring rate, the rotational forces surpass the magnetic field and the MIL disperses into the sample solution in a similar manner to DLLME. After extraction, the stirring is stopped and the MIL returns to the stir bar without the requirement of an additional external magnetic field. The MIL-coated stir bar containing the preconcentrated analytes is thermally desorbed directly into a gas chromatographic system coupled to a mass spectrometric detector (TD-GC-MS). This novel approach opens new insights into the microextraction field, by using the benefits provided by SBSE and DLLME simultaneously, such as automated thermal desorption and high surface contact area, respectively, but most importantly, it enables the use of tailor-made solvents (i.e., MILs). To prove its utility, SBDLME has been used in the extraction of lipophilic organic UV filters from environmental water samples as model analytical application with excellent analytical features in terms of linearity, enrichment factors (67-791), limits of detection (low ng L -1 ), intra- and inter-day repeatability (RSD<15%) and relative recoveries (87-113%, 91-117% and 89-115% for river, sea and swimming pool water samples, respectively). Copyright © 2017 Elsevier B.V. All rights reserved.
Gao, Guihua; Li, Sijia; Li, Shuo; Wang, Yudan; Zhao, Pan; Zhang, Xiangyu; Hou, Xiaohong
2018-04-01
In this work, computational and experimental methods were used to study the adsorption of estrogens and glucocorticoids on metal-organic frameworks (MOFs). Computer-aided molecular simulation was applied to predict the adsorption of eight analytes on four MOFs (MIL-101(Cr), MIL-100(Fe), MIL-53(Al), and UiO-66(Zr)) by examining molecular interactions and calculating free binding energies. Subsequently, the four water-stable MOFs were synthesized and evaluated as adsorbents for the target hormones in aqueous solution. As the MOF exhibiting the highest adsorption capacity in both computations and experiments, MIL-53(Al) was chosen as a sorbent to develop a dispersive micro-solid-phase extraction procedure coupled to ultra-performance liquid chromatography tandem mass spectrometry for simultaneous determination of the target analytes in water and human urine samples. Experimental parameters affecting the extraction recoveries, including pH, ionic strength, MIL-53(Al) amount, extraction time, desorption time, and desorption solvent, were optimized. The optimized method provided a linear range of 0.005025-368.6μg/L with good correlation coefficients (0.9982 ≤ r 2 ≤ 0.9992), and limits of detection (S/N = 3) and quantification (S/N = 10) of 0.0015-1.0μg/L and 0.005-1.8μg/L, respectively. The analyte recoveries were in the range of 80.6-98.4% in water samples and 88.4-93.2% in urine samples. Furthermore, MIL-53(Al) showed good stability over 10 extraction cycles (RSD < 10.0%). Good agreement between experimental measurements and computational results showed the potential of this approach for elucidating adsorption mechanisms and predicating extraction efficiencies for MOFs and targets, providing new directions for the development and utilization of MOFs. Copyright © 2017 Elsevier B.V. All rights reserved.
Structurally stable, thin silicon solar cells
NASA Technical Reports Server (NTRS)
Arndt, R. A.; Meulenberg, A.
1984-01-01
A fabrication process for structurally stable thin solar cell wafers that produce good power output after irradiation is described. The fabrication process is as follows. A 6 mil, circular wafer is oxidized on both sides. One side is then patterned with a rectangular array of holes in the oxide that are nominally 75 mils square and separated by 2 mil spacings. Wells are then etched into the silicon with KOH to a depth of 4 mils, leaving a 2 mil, unetched thickness. Two areas on the surface are left unetched to provide pads for bonding or testing. All oxide is then removed and the rest of the processing is normal; the unetched face is used as the illuminated face. When all other processing is complete, a 2 X 2 cm cell is sawed from the starting wafer leaving a border that is approximately 10 mils wide. The effective thickness, determined by weighing an unmetallized sample, of such a cell is about 2.4 mil.
Experience of Data Handling with IPPM Payload
NASA Astrophysics Data System (ADS)
Errico, Walter; Tosi, Pietro; Ilstad, Jorgen; Jameux, David; Viviani, Riccardo; Collantoni, Daniele
2010-08-01
A simplified On-Board Data Handling system has been developed by CAEN AURELIA SPACE and ABSTRAQT as PUS-over-SpaceWire demonstration platform for the Onboard Payload Data Processing laboratory at ESTEC. The system is composed of three Leon2-based IPPM (Integrated Payload Processing Module) computers that play the roles of Instrument, Payload Data Handling Unit and Satellite Management Unit. Two PCs complete the test set-up simulating an external Memory Management Unit and the Ground Control Unit. Communication among units take place primarily through SpaceWire links; RMAP[2] protocol is used for configuration and housekeeping. A limited implementation of ECSS-E-70-41B Packet Utilisation Standard (PUS)[1] over CANbus and MIL-STD-1553B has been also realized. The Open Source RTEMS is running on the IPPM AT697E CPU as real-time operating system.
Soil Ciliates from Saudi Arabia, Including Descriptions of Two New Genera and Six New Species.
Foissner, Wilhelm; Quintela-Alonso, Pablo; Al-Rasheid, Khaled
2008-01-01
Six soil samples from natural and cultivated sites of Saudi Arabia were investigated for ciliate diversity, using the non-flooded Petri dish culture method, live observation, and silver impregnation. We identified 135 species, all new for the fauna of Saudi Arabia, of which seven were undescribed: Spathidium alqasabi nov. spec.; Enchelyodon alqasabi nov. spec.; Metauroleptus arabicus nov. gen., nov. spec.; Pseudohemisincirra arabica nov. gen., nov. spec.; Saudithrix terricola Berger, Al-Rasheid and Foissner, 2006; Oxytricha arabica nov. spec.; and Erimophrya monostyla nov. spec. Based on Spathidium alqasabi, S. seppelti foissneri Vd'ačný et al., 2006 and S. seppelti etoschense Foissner et al., 2002 are raised to species rank; for the latter, a new name is required to avoid homonymy: Spathidium fraterculum nov. nom. The new genus Metauroleptus, which possesses two long and two to three short ventral cirral rows, generates all dorsal kineties intrakinetally and produces caudal cirri exclusively in dorsal kinety 1. Metauroleptus belongs to the hypotrichs, while family classification remains doubtful. The same applies to the new hypotrich genus Pseudohemisincirra, which has frontoventral and transverse cirri, while buccal cirri and caudal cirri are absent. The number of species contained in Saudi Arabian soils, including sand dunes, is in the range reported from other regions of the earth, suggesting that ciliates are well adapted to dry habitats, possibly mainly by their ability to produce very resistant resting cysts, most surviving for a long time due to reduced metazoan predation.
Cipolat-Gotet, C; Cecchinato, A; Stocco, G; Bittante, G
2016-02-01
The aim of this study was to propose and test a new laboratory cheesemaking procedure [9-mL milk cheesemaking assessment (9-MilCA)], which records 15 traits related to milk coagulation, curd firming, syneresis, cheese yield, and curd nutrients recovery or whey loss. This procedure involves instruments found in many laboratories (i.e., heaters and lacto-dynamographs), with an easy modification of the sample rack for the insertion of 10-mL glass tubes. Four trials were carried out to test the 9-MilCA procedure. The first trial compared 8 coagulation and curd firming traits obtained using regular or modified sample racks to process milk samples from 60 cows belonging to 5 breeds and 3 farms (480 tests). The obtained patterns exhibited significant but irrelevant between-procedure differences, with better repeatability seen for 9-MilCA. The second trial tested the reproducibility and repeatability of the 7 cheesemaking traits obtained using the 9-MilCA procedure on individual samples from 60 cows tested in duplicate in 2 instruments (232 tests). The method yielded very repeatable outcomes for all 7 tested cheese yield and nutrient recovery traits (repeatability >98%), with the exception of the fresh cheese yield (84%), which was affected by the lower repeatability (67%) of the water retained in the curd. In the third trial (96 tests), we found that using centrifugation in place of curd cooking and draining (as adopted in several published studies) reduced the efficiency of whey separation, overestimated all traits, and worsened the repeatability. The fourth trial compared 9-MilCA with a more complex model cheese-manufacturing process that mimics industry practices, using 1,500-mL milk samples (72 cows, 216 tests). The average results obtained from 9-MilCA were similar to those obtained from the model cheeses, with between-method correlations ranging from 78 to 99%, except for the water retained in the curd (r=54%). Our results indicate that new 9-MilCA method is a powerful research tool that allows the rapid, inexpensive, and partly automated analysis processing 40 samples per day with 2 replicates each, using 1 lacto-dynamograph, 2 heaters, and 3 modified sample racks, and yields a complete picture of the cheesemaking process (e.g., milk gelation, curd firming, syneresis, and whey expulsion) as well as the cheese yield and the efficiency of energy or nutrients retention in the cheese or loss in the whey. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
High reliability bond program using small diameter aluminum wire
NASA Technical Reports Server (NTRS)
Macha, M.; Thiel, R. A.
1975-01-01
The program was undertaken to characterize the performance of small diameter aluminum wire ultrasonically bonded to conductors commonly encountered in hybrid assemblies, and to recommend guidelines for improving this performance. Wire, 25.4, 38.1 and 50.8 um (1, 1.5 and 2 mil), was used with bonding metallization consisting of thick film gold, thin film gold and aluminum as well as conventional aluminum pads on semiconductor chips. The chief tool for evaluating the performance was the double bond pull test in conjunction with a 72 hour - 150 C heat soak and -65 C to +150 C thermal cycling. In practice the thermal cycling was found to have relatively little effect compared to the heat soak. Pull strength will decrease after heat soak as a result of annealing of the aluminum wire; when bonded to thick film gold, the pull strength decreased by about 50% (weakening of the bond interface was the major cause of the reduction). Bonds to thin film gold lost about 30 - 40% of their initial pull strenth; weakening of the wire itself at the bond heel was the predominant cause. Bonds to aluminum substrate metallization lost only about 22%. Bonds between thick and thin film gold substrate metallization and semiconductor chips substantiated the previous conclusions but also showed that in about 20 to 25% of the cases, bond interface failure occurred at the semiconductor chip.
Stable-isotope ratios of hydrogen and oxygen in precipitation at Norman, Oklahoma, 1996-2008
Jaeschke, Jeanne B.; Scholl, Martha A.; Cozzarelli, Isabelle M.; Masoner, Jason R.; Christenson, Scott; Qi, Haiping
2011-01-01
Precipitation samples for measurement of stable-isotope ratios of hydrogen (delta2H) and oxygen (delta18O) were collected at the Norman Landfill Research Site in Norman, Oklahoma, from May 1996 to October 2008. Rainfall amounts also were measured at the site (U.S. Geological Survey gaging station 07229053) during the collection period. The delta2H of precipitation samples ranged from -121.9 to +8.3 per mil, and the delta18O of precipitation ranged from -16.96 to +0.50 per mil. The volume-weighted average values for delta2H and delta18O of precipitation over the 12-year measurement period were -31.13 per mil for delta2H and -5.57 per mil for delta18O. Average summer-season delta2H and delta18O values of precipitation usually were more positive (enriched in the heavier isotopes) than winter values.
NASA Technical Reports Server (NTRS)
Blue, G. D.; Moran, C. M.
1985-01-01
Corrosion rates of 304L stainless steel coupons in MON-1 oxidizer have been measured as a function of cleaning procedures employed, surface layer positions, propellant impurity levels, and short-term exposure durations (14 to 90 days). Of special interest was propellant contamination by buildup of soluble iron, which may cause flow decay. Surface treatments employed were combinations of cleaning, pickling, and passivation procedures. Propellants used were MIL-SPEC MON-1 and several types of purified NTO (i.e., low water, low chloride) which may, at a later time, be specified as spacecraft grade. Pretest coupon surface analysis by X-ray photoelectron spectroscopy (XPS-ESCA) has revealed important differences, for the different cleaning procedures, in the make-up of the surface layer, both in composition and state of chemical combination of the elements involved. Comparisons will be made of XPS/ESCA data, for different cleaning procedures, for specimens before and after propellant exposure.
Evaluation of Pd-Cr Wires for Strain Gage Application
NASA Technical Reports Server (NTRS)
Lei, Jih-Fen; Greer, L. C., III; Oberle, L. G.
1995-01-01
A newly developed alloy, palladium-13 weight percent chromium (Pd13Cr), was identified by United Technologies Research Center under a NASA contract to be the best material for high temperature strain gage applications. An electrical resistance strain gage that can provide accurate static strain measurement to a temperature higher than that of a commercially available gage is urgently needed in aerospace and aeronautics research. A strain gage made of a 25.4 micron (1 mil) diameter Pd13Cr wire has been recently demonstrated to be usable for static strain measurements to 800 C. This compares to the 400 C temperature limit of the commercially available strain gages. The performance of the Pd-Cr gage, however, strongly depends on the quality of the Pd13Cr wire. Four batches of Pd-Cr wires purchased from three different manufacturers were therefore evaluated to determine the best source of the wire for strain gage applications. The three suppliers were Precious Metal Institute in China, Sigmund Cohn Co., and G & S Titanium, Inc. in the United States. Two batches of wires obtained from Previous Metal Institute in 1987 and 1992, respectively are referred to herein as China87 and China92 wires. The mechanical, chemical and electrical properties of these wires, both as-received and after high temperature exposures at 800 C for 50 hours were analyzed. The elastic modulus and the failure strength of the wires were evaluated using a tensile test machine equipped with a laser speckle strain measurement system. The chemical and microstructural properties of the wires were inspected using a plasma atomic emission spectrometer and a scanning electron microscope (SEM) equipped with an energy dispersive X-ray spectroscope (EDS). The electrical stability and repeatability of the wires were determined by measuring the electrical resistance of the wires during three thermal cycles to 1000 C and a ten-hour soak at 1000 C. As a result of this study, the wire which has the highest strength, the least impurities content, the best oxidation resistance and the best electrical stability will be selected for upcoming strain gage applications.
Magnetic Design Guidelines for Electronic Power Supplies.
1986-09-30
henries ",= peak flux density in gauss d = wire (conductor) dia in mils CM = d2 = circular mi’s Irms = RMS current in amperes Idc = DC current in...component lac = RMS ac current in the inductor f = minimum frequency in hertz L = inductance in henries Then Eac 2 16.83 x 2, x 760 x .05 10 Eac 1 168.3 x 2...duty cycle x 1/f L inductance in henries *permeability in gauss/oersted H magnetizing force in oersteds ’. i g length of air gap in cm ic length of
Liu, Youxun; Geng, Yuanyuan; Yan, Mingyang; Huang, Juan
2017-06-02
The successful encapsulation of 2,2'-azino-bis(3-ethylbenzthiazoline-6-sulfonic acid) (ABTS), a well-known laccase mediator, within a mesoporous metal-organic framework sample (i.e., MIL-100(Fe)) was achieved using a one-pot hydrothermal synthetic method. The as-prepared ABTS@MIL-100(Fe) was characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy, nitrogen sorption, and cyclic voltammetry (CV). Our ABTS@MIL-100(Fe)-based electrode exhibited an excellent electrochemical response, indicating that MIL-100(Fe) provides an appropriate microenvironment for the immobilization and electroactivity of ABTS molecules. ABTS@MIL-100(Fe) was then evaluated as an immobilized laccase mediator for dye removal using indigo carmine (IC) as a model dye. Through the application of laccase in combination with a free (ABTS) or immobilized (ABTS@MIL-100(Fe)) mediator, decolorization yields of 95% and 94%, respectively, were obtained for IC after 50 min. In addition, following seven reuse cycles of ABTS@MIL-100(Fe) for dye treatment, a decolorization yield of 74% was obtained. Dye decolorization occurred through the breakdown of the chromophoric group by the Laccase/ABTS@MIL-100(Fe) system, and a catalytic mechanism was proposed. We therefore expect that the stability, reusability, and validity of ABTS@MIL-100(Fe) as a laccase mediator potentially render it a promising tool for dye removal, in addition to reducing the high running costs and potential toxicity associated with synthetic mediators.
Shrira, Amit; Shmotkin, Dov; Palgi, Yuval; Soffer, Yechiel; Hamama Raz, Yaira; Tal-Katz, Patricia; Ben-Ezra, Menachem; Benight, Charles C
2015-01-01
We examined how positive affect (PA) and meaning in life (MIL) conjointly regulate posttraumatic stress disorder (PTSD) symptoms and perceived coping self-efficacy. Hypotheses were guided by a recent holistic model, according to which PA and MIL should compensate for each other in relating to adaptation to high stress. The sample included 75 Israeli firefighters who took active part in extinguishing the 2010 Mount Carmel forest fire. PA and MIL helped to compensate for the other, demonstrating that when one of them was low, the other related to higher adaptation. That is, under low MIL, PA related to PTSD symptoms and coping self-efficacy, and under low PA, MIL related to PTSD symptoms and coping self-efficacy. The study design was cross-sectional and therefore precluded any causal inferences. The findings lend additional support to the holistic model and help to understand how subjective well-being and MIL correlate with adaptation to stress.
NASA Astrophysics Data System (ADS)
Rebelo Kornmeier, Joana; Ostermann, Andreas; Hofmann, Michael; Gibmeier, Jens
2014-02-01
Neutron strain diffractometers usually use slits to define a gauge volume within engineering samples. In this study a multi-channel parabolic neutron guide was developed to be used instead of the primary slit to minimise the loss of intensity and vertical definition of the gauge volume when using slits placed far away from the measurement position in bulky components. The major advantage of a focusing guide is that the maximum flux is not at the exit of the guide as for a slit system but at the focal point relatively far away from the exit of the guide. Monte Carlo simulations were used to optimise the multi-channel parabolic guide with respect to the instrument characteristics of the diffractometer STRESS-SPEC at the FRM II neutron source. Also the simulations are in excellent agreement with experimental measurements using the optimised multi-channel parabolic guide at the neutron diffractometer. In addition the performance of the guide was compared to the standard slit setup at STRESS-SPEC using a single bead weld sample used in earlier round robin tests for residual strain measurements.
Velocity profile of water vapor inside a cavity with two axial inlets and two outlets
NASA Astrophysics Data System (ADS)
Guadarrama-Cetina, José; Ruiz Chavarría, Gerardo
2014-03-01
To study the dynamics of Breath Figure phenomenon, a control of both the rate of flow and temperature of water vapor is required. The experimental setup widely used is a non hermetically closed chamber with cylindrical geometry and axial inlets and outlets. In this work we present measurements in a cylindrical chamber with diameter 10 cm and 1.5 cm height, keeping a constant temperature (10 °C). We are focused in the velocity field when a gradient of the temperatures is produced between the base plate and the vapor. With a flux of water vapor of 250 mil/min at room temperature (21 °C), the Reynolds number measured in one inlet is 755. Otherwise, the temperatures of water vapor varies from 21 to 40 °C. The velocity profile is obtained by hot wire anemometry. We identify the stagnations and the possibly instabilities regions for an empty plate and with a well defined shape obstacle as a fashion sample. Facultad de Ciencias, UNAM.
Helwerda, Renate A
2015-07-24
Twenty-three species of Acteonidae, Bullinidae and Ringiculidae are documented from the so-called "Cabarruyan" fauna from the Plio-Pleistocene of Pangasinan, the Philippines. There are eleven species of Acteonidae, one species of Bullinidae and eleven species of Ringiculidae. Seven species are described here as new, these are: Bathyacteon valdesi nov. spec., Bullina virgoides nov. spec., Ringicula bella nov. spec., R. circumscripta nov. spec., R. caelestis nov. spec., R. opima nov. spec. and Microglyphis angulata nov. spec.. The presence of Acteonidae and Bullinidae indicates that polychaete worms were also present.
TAB interconnects for space concentrator solar cell arrays
NASA Technical Reports Server (NTRS)
Avery, J.; Bauman, J. S.; Gallagher, P.; Yerkes, J. W.
1993-01-01
The Boeing Company has evaluated the use of Tape Automated Bonding (TAB) and Surface Mount Technology (SMT) for a highly reliable, low cost interconnect for concentrator solar cell arrays. TAB and SMT are currently used in the electronics industry for chip interconnects and printed circuit board assembly. TAB tape consists of sixty-four 3-mil/1-oz tin-plated copper leads on 8-mil centers. The leads are thermocompression gang bonded to GaAs concentrator solar cell with silver contacts. This bond, known as an Inner Lead Bond (ILB), allows for pretesting and sorting capability via nondestruct wire bond pull and flash testing. Destructive wire pull tests resulted in preferred mid-span failures. Improvements in fill factor were attributed to decreased contact resistance on TAB bonded cells. Preliminary thermal cycling and aging tests were shown excellent bond strength and metallurgical results. Auger scans of bond sites reveals an Ag-Cu-Tin composition. Improper bonds are identified through flash testing as a performance degradation. On going testing of cells are underway at Lewis Research Center. SMT techniques are utilized to excise and form TAB leads post ILB. The formed leads' shape isolates thermal mismatches between the cells and the flex circuit they are mounted on. TABed cells are picked and placed with a gantry x-y-z positioning system with pattern recognition. Adhesives are selected to avoid thermal expansion mismatch and promote thermal transfer to the flex circuit. TAB outer lead bonds are parallel gap welded (PGW) to the flex circuit to finish the concentrator solar cell subassembly.
Li, Xiao-jun; Yi, Eugene C; Kemp, Christopher J; Zhang, Hui; Aebersold, Ruedi
2005-09-01
There is an increasing interest in the quantitative proteomic measurement of the protein contents of substantially similar biological samples, e.g. for the analysis of cellular response to perturbations over time or for the discovery of protein biomarkers from clinical samples. Technical limitations of current proteomic platforms such as limited reproducibility and low throughput make this a challenging task. A new LC-MS-based platform is able to generate complex peptide patterns from the analysis of proteolyzed protein samples at high throughput and represents a promising approach for quantitative proteomics. A crucial component of the LC-MS approach is the accurate evaluation of the abundance of detected peptides over many samples and the identification of peptide features that can stratify samples with respect to their genetic, physiological, or environmental origins. We present here a new software suite, SpecArray, that generates a peptide versus sample array from a set of LC-MS data. A peptide array stores the relative abundance of thousands of peptide features in many samples and is in a format identical to that of a gene expression microarray. A peptide array can be subjected to an unsupervised clustering analysis to stratify samples or to a discriminant analysis to identify discriminatory peptide features. We applied the SpecArray to analyze two sets of LC-MS data: one was from four repeat LC-MS analyses of the same glycopeptide sample, and another was from LC-MS analysis of serum samples of five male and five female mice. We demonstrate through these two study cases that the SpecArray software suite can serve as an effective software platform in the LC-MS approach for quantitative proteomics.
Sharp, Jonathan D; Byrne, Robert H; Liu, Xuewu; Feely, Richard A; Cuyler, Erin E; Wanninkhof, Rik; Alin, Simone R
2017-08-15
This work describes an improved algorithm for spectrophotometric determinations of seawater carbonate ion concentrations ([CO 3 2- ] spec ) derived from observations of ultraviolet absorbance spectra in lead-enriched seawater. Quality-control assessments of [CO 3 2- ] spec data obtained on two NOAA research cruises (2012 and 2016) revealed a substantial intercruise difference in average Δ[CO 3 2- ] (the difference between a sample's [CO 3 2- ] spec value and the corresponding [CO 3 2- ] value calculated from paired measurements of pH and dissolved inorganic carbon). Follow-up investigation determined that this discordance was due to the use of two different spectrophotometers, even though both had been properly calibrated. Here we present an essential methodological refinement to correct [CO 3 2- ] spec absorbance data for small but significant instrumental differences. After applying the correction (which, notably, is not necessary for pH determinations from sulfonephthalein dye absorbances) to the shipboard absorbance data, we fit the combined-cruise data set to produce empirically updated parameters for use in processing future (and historical) [CO 3 2- ] spec absorbance measurements. With the new procedure, the average Δ[CO 3 2- ] offset between the two aforementioned cruises was reduced from 3.7 μmol kg -1 to 0.7 μmol kg -1 , which is well within the standard deviation of the measurements (1.9 μmol kg -1 ). We also introduce an empirical model to calculate in situ carbonate ion concentrations from [CO 3 2- ] spec . We demonstrate that these in situ values can be used to determine calcium carbonate saturation states that are in good agreement with those determined by more laborious and expensive conventional methods.
Water and carbon in rusty lunar rock 66095
Friedman, I.; Hardcastle, Kenneth G.; Gleason, J.D.
1974-01-01
Lunar rock 66095 contains a hydrated iron oxide and has an unusual amount of water for a lunar rock (140 to 750 parts per million), 90 percent of which is released below 690??C. The ??D of water released at these low temperatures varies from -75 to -140 per mil relative to standard mean ocean water (SMOW). The small amount of water released between 690?? and 1300??C has a ??D of about -175 ?? 25 per mil SMOW. These ??D values are not unusual for terrestrial water. The ??18O of water extracted from 110?? to 400??C has a value of + 5 ?? 1 per mil SMOW, similar to the value for lunar silicates from rock 66095 and different from the value of -4 to -22 per mil found for samples of terrestrial rust including samples of rusted meteoritic iron. The amount of carbon varies from 11 to 59 parts per million with a ??13C from -20 to -30 per mil relative to Pee Dee belemnite. Only very small amounts of reduced species (such as hydrogen, carbon monoxide, and methane) were found, in contrast to the analyses of other lunar rocks. Although it is possible that most of the water in the iron oxide (goethite) may be terrestrial in origin or may have exchanged with terrestrial water during sample return and handling, evidence presented herein suggests that this did not happen and that some lunar water may have a ??D that is indistinguishable from that of terrestrial water.
Battaglin, William A.; Kendall, Carol; Chang, Cecily C.Y.; Silva, Steven R.; Campbell, Donald H.
2001-01-01
Nitrate (NO3) and other nutrients discharged by the Mississippi River combined with seasonal stratification of the water column are known to cause a zone of depleted dissolved oxygen (hypoxic zone) in the Gulf of Mexico each summer. About 120 water and suspended sediment samples collected in 1997 and 1998 from 24 locations in the Mississippi River Basin were analyzed for the isotope ratios δ15N and δ18O of dissolved NO3, and δ15N and δ13C of suspended particulate organic material (POM). Sampling stations include both large rivers (drainage areas more than 30,000 square kilometers) that integrate the effects of many land uses, and smaller streams (drainage areas less than 2,500 square kilometers) that have relatively uniform land use within their drainage areas. The data are used to determine sources and transformations of NO3 in the Mississippi River.Results of this study demonstrate that much of the NO3 in the Mississippi River originates in the agriculturally dominated basins of the upper midwestern United States and is transported without significant transformation or other loss to the Gulf of Mexico. Results from major tributaries that drain into the Mississippi River suggest that NO3 is not significantly altered by denitrification in its journey, ultimately, to the Gulf of Mexico. The spatial variability of isotope ratios among the smaller streams appears to be related to the dominant nitrogen source in the basins. There are some distinct isotope differences among land-use types. For example, for both NO3 and POM, the majority of δ15N isotope ratio values from basins dominated by urban and undeveloped land are less than +5 per mil, whereas the majority of values from basins dominated by row crops and row crops and/or livestock production are greater than +5 per mil. Also, the median δ18O of NO3 isotope ratio value (+14.0 per mil) from undeveloped basins is more than 6 per mil higher than the median value (+7.3 per mil) from the row crop dominated basins and 5 per mil higher than the median value (+9.0 per mil) from the row crop and/or livestock production dominated basins. The median δ18O of NO3 isotope ratio value (+21.5 per mil) from urban basins is 6.5 per mil higher than the median value (+14.0 per mil) from the undeveloped basins. The majority of NO3 concentrations are greater than 3 milligrams per liter (mg/L) in basins dominated by row crops and row crops and/or livestock production, whereas all NO3 concentrations are less than 2 mg/L in basins dominated by urban and undeveloped land.
Sukumaran, Suja
2011-02-17
Nucleic acid quantitation procedures have advanced significantly in the last three decades. More and more, molecular biologists require consistent small-volume analysis of nucleic acid samples for their experiments. The BioSpec-nano provides a potential solution to the problems of inaccurate, non-reproducible results, inherent in current DNA quantitation methods, via specialized optics and a sensitive PDA detector. The BioSpec-nano also has automated functionality such that mounting, measurement, and cleaning are done by the instrument, thereby eliminating tedious, repetitive, and inconsistent placement of the fiber optic element and manual cleaning. In this study, data is presented on the quantification of DNA and protein, as well as on measurement reproducibility and accuracy. Automated sample contact and rapid scanning allows measurement in three seconds, resulting in excellent throughput. Data analysis is carried out using the built-in features of the software. The formula used for calculating DNA concentration is: Sample Concentration = DF · (OD260-OD320)· NACF (1) Where DF = sample dilution factor and NACF = nucleic acid concentration factor. The Nucleic Acid concentration factor is set in accordance with the analyte selected. Protein concentration results can be expressed as μg/mL or as moles/L by entering e280 and molecular weight values respectively. When residue values for Tyr, Trp and Cysteine (S-S bond) are entered in the e280Calc tab, the extinction coefficient values are calculated as e280 = 5500 x (Trp residues) + 1490 x (Tyr residues) + 125 x (cysteine S-S bond). The e280 value is used by the software for concentration calculation. In addition to concentration determination of nucleic acids and protein, the BioSpec-nano can be used as an ultra micro-volume spectrophotometer for many other analytes or as a standard spectrophotometer using 5 mm pathlength cells.
Sukumaran, Suja
2011-01-01
Nucleic Acid quantitation procedures have advanced significantly in the last three decades. More and more, molecular biologists require consistent small-volume analysis of nucleic acid samples for their experiments. The BioSpec-nano provides a potential solution to the problems of inaccurate, non-reproducible results, inherent in current DNA quantitation methods, via specialized optics and a sensitive PDA detector. The BioSpec-nano also has automated functionality such that mounting, measurement, and cleaning are done by the instrument, thereby eliminating tedious, repetitive, and inconsistent placement of the fiber optic element and manual cleaning. In this study, data is presented on the quantification of DNA and protein, as well as on measurement reproducibility and accuracy. Automated sample contact and rapid scanning allows measurement in three seconds, resulting in excellent throughput. Data analysis is carried out using the built-in features of the software. The formula used for calculating DNA concentration is: Sample Concentration = DF · (OD260-OD320)· NACF (1) Where DF = sample dilution factor and NACF = nucleic acid concentration factor. The Nucleic Acid concentration factor is set in accordance with the analyte selected1. Protein concentration results can be expressed as μg/ mL or as moles/L by entering e280 and molecular weight values respectively. When residue values for Tyr, Trp and Cysteine (S-S bond) are entered in the e280Calc tab, the extinction coefficient values are calculated as e280 = 5500 x (Trp residues) + 1490 x (Tyr residues) + 125 x (cysteine S-S bond). The e280 value is used by the software for concentration calculation. In addition to concentration determination of nucleic acids and protein, the BioSpec-nano can be used as an ultra micro-volume spectrophotometer for many other analytes or as a standard spectrophotometer using 5 mm pathlength cells. PMID:21372788
Lirio, Stephen; Liu, Wan-Ling; Lin, Chen-Lan; Lin, Chia-Her; Huang, Hsi-Ya
2016-01-08
In this study, aluminum based metal-organic framework (Al-MOF)-organic polymer monoliths were prepared via microwave-assisted polymerization of ethylene dimethacrylate (EDMA), butyl methacrylate (BMA) with different weight percentages of Al-MOF (MIL-53; 37.5-62.5%) and subsequently utilized as sorbent in solid-phase microextraction (SPME) of penicillins (penicillin G, penicillin V, oxacillin, cloxacillin, dicloxacillin, nafcillin). The Al-MOF-polymer was characterized using Fourier transform infrared (FTIR) spectroscopy, powder X-ray diffraction (XRD), scanning electron microscopy (SEM) and SEM-energy-dispersive X-ray spectroscopy (SEM-EDS) to clarify the retained crystalline structure well as the homogeneous dispersion of Al-MOF (MIL-53) in polymer monolith. The developed Al-MOF-polymer (MIL-53) monolithic column was evaluated according to its extraction recovery of penicillins. Several parameters affecting the extraction recoveries of penicillins using fabricated Al-MOF-polymer (MIL-53) monolithic column including different MIL-53 weight percentages, column length, pH, desorption solvent, and mobile phase flow rate were investigated. For comparison, different Al-based MOFs (MIL-68, CYCU-4 and DUT-5) were fabricated using the optimized condition for MIL-53-polymer (sample matrix at pH 3, 200μL desorption volume using methanol, 37.5% of MOF, 4-cm column length at 0.100mLmin(-1) flow rate). Among all the Al-MOF-polymers, MIL-53(Al)-polymer still afforded the best extraction recovery for penicillins ranging from 90.5 to 95.7% for intra-day with less than 3.5% relative standard deviations (RSDs) and inter-day precision were in the range of 90.7-97.6% with less than 4.2% RSDs. Meanwhile, the recoveries for column-to-column were in the range of 89.5-93.5% (<3.4% RSDs) while 88.5-90.5% (<5.8% RSDs) for batch-to-batch (n=3). Under the optimal conditions, the limit of detections were in the range of 0.06-0.26μgL(-1) and limit of quantifications between 0.20 and 0.87μgL(-1). Finally, the MIL-53-polymer was applied for the extraction of penicillin in river water and milk by spiking trace-level penicillin for as low as 50μgL(-1) and 100μgL(-1) with recoveries ranging from 80.8% to 90.9% (<6.7% RSDs) in river water and 81.1% to 100.7% (<7.1% RSDs) in milk sample, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.
Bernard, Mathieu; Braunschweig, Giliane; Fegg, Martin Johannes; Borasio, Gian Domenico
2015-09-29
The concept of meaning in life (MIL) has become a central one in recent years, particularly in psycho-oncology and palliative care. The Schedule for Meaning in Life Evaluation (SMILE) has been developed to allow individuals to choose the life areas that they consider to be important for their own MIL. This approach relates to the "World Health Organisation" definition of quality of life (QOL) as an individual's perception of his own position. The aims of this study were (i) to assess MIL in a representative sample of the Swiss population according to the three linguistic regions and (ii) to evaluate whether MIL constitutes a significant determinant of the perceived QOL. A telephone survey of the Swiss population, performed by a professional survey company, was conducted between November and December 2013. The interview included the SMILE, perceived QOL (0-10) and health status (1-5), and various sociodemographic variables. In the SMILE, an index of weighting (IOW, 20-100), an index of satisfaction (IOS, 0-100), and a total SMILE index (IOWS, 0-100) are calculated from the areas mentioned by the participants as providing MIL. Among the 6671 telephonic contacts realized, 1015 (15%) participants completed the survey: 405 French, 400 German and 210 Italian participants. "Family" (80.2%), "occupation/work" (51%), and "social relations" (43.3%) were the most cited MIL-relevant categories. Italian participants listed "health" more frequently than German and French participants (50.4% vs 31.5% and 24.8% respectively, χ(2) = 12.229, p = .002). Age, gender, education, employment, and marital status significantly influenced either the MIL scores or the MIL-relevant categories. Linear regression analyses indicate that 24.3% of the QOL variance (p = .000) is explained by health status (B = .609, IC = .490-.728, p = .000), MIL (B = .034, IC = .028-.041, p = .000) and socioeconomic status (F = 11.01, p = .000). The major finding of our analysis highlights the positive and significant influence of MIL on the perceived QOL in a representative sample of a general, multilingual and multicultural population. This result indicates that the existential dimension is not only determinant for QOL in some critical life events, as shown e.g. in psycho-oncology and palliative care, but also in everyday life.
NASA Astrophysics Data System (ADS)
Wang, Minghua; Yang, Longyu; Hu, Bin; Liu, Yongkang; Song, Yingpan; He, Linghao; Zhang, Zhihong; Fang, Shaoming
2018-07-01
A novel electrocatalyst based on amine-functionalized Ti-based metal-organic framework (NH2-MIL-125(Ti)) embedded with Cu3P nanocrystals (denoted by Cu3P@NH2-MIL-125(Ti)) was synthesized and used for electrocatalytic oxidation and detection of hydrazine in aqueous solution. A series of Cu3P@NH2-MIL-125(Ti) nanocomposites were obtained by adding Cu3P nanoparticles into the preparation system of NH2-MIL-125(Ti), with the Cu3P nanocrystals derived from the phospatization of Cu(OH)2 at high temperature. Based on the detailed characterizations and analysis of the chemical and physical performances of the series of Cu3P@NH2-MIL-125(Ti) nanocomposites at dosages of Cu3P nanocrystals at 5, 20, 50, and 100 mg, the good synergic effect between the Cu3P (50 mg) and the NH2-MIL-125(Ti) endows the as-prepared Cu3P50@NH2-MIL-125(Ti) nanocomposite with the excellent electrocatalytic activity toward the electrocatalytic oxidation of hydrazine. The Cu3P50@NH2-MIL-125(Ti)-based electrochemical sensor exhibited a detection limit of 79 nM (S/N = 3) within a wider linear range from 5 μM to 7.5 mM. Moreover, the developed sensor exhibited high selectivity toward the detection of hydrazine with the addition of certain common interferents and good applicability in real samples. All of these results imply that the Cu3P50@NH2-MIL-125(Ti) nanocomposite could be promising for detecting hydrazine and offer potential applications in the field of electroanalytical chemistry.
Li, Fengyuan; Li, Shuqiang; Jäger, Peter
2014-02-25
Five new Althepus species and one new Psiloderces species of the family Ochyroceratidae are described from Southeast Asia: Althepus erectus spec. nov. (male) and A. nophaseudi spec. nov. (male, female) from Laos, A. flabellaris spec. nov. (male, female) from Thailand, A. reduncus spec. nov. (male) from Myanmar, A. spiralis spec. nov. (male) from Malaysia, and Psiloderces dicellocerus spec. nov. (male) from Indonesia. Primary types are deposited in the Senckenberg Research Institute in Frankfurt, Germany (SMF).
Diffraction on heavy samples at STRESS-SPEC using a robot system
NASA Astrophysics Data System (ADS)
Al-Hamdany, N.; Gan, W. M.; Randau, C.; Brokmeier, H.-G.; Hofmann, M.
2015-04-01
The material science diffractometer STRESS-SPEC has high flux and a high flexible monochromator arrangement to optimize the needed wavelength. Many specific sample handling stages and sample environments are available. One of them is a Staubli RX 160 robot with nominal load capacity of 20 kg and more freedom for texture mapping than the Huber 512 Eulerian type cradle. Demonstration experiments of non-destructive pole figures and strain measurements of Cu-tube segments weighing 12 kg weight and 250 mm in length and 140 mm diameter have been carried out. The residual strains measured by the robot and by the XYZ- stage fit quite well, that means the robot is reliable for strain measurements. The texture of the Cu-tube has dominant recrystallization texture components represented by the cube and the rotated cube.
Detection and differentiation of biological species using microcalorimetric spectroscopy.
Arakawa, E T; Lavrik, N V; Rajic, S; Datskos, P G
2003-01-01
We report on the application of infrared (IR) microcalorimetric spectroscopy ( micro -CalSpec) to the identification and detection of trace amounts of biological species. Our approach combines principles of photothermal IR spectroscopy with ultrasensitive microcantilever (MC) thermal detectors. We have obtained photothermal IR spectra for DNA and RNA bases and for Bacillus Cereus (an anthrax simulant) in the wavelength range of 2.5-14.5 micro m (4000-690 cm(-1)). The measurements are accomplished by absorbing biological materials directly on a MC thermal detector. The main advantage of the developed micro -CalSpec is its unprecedented sensitivity as compared to any of the previously explored IR techniques, including FTIR and photothermal FTIR methods. Our results demonstrate that <10(-9)g of a biological sample is sufficient to obtain its characteristic micro -CalSpec spectrum that contains information-rich chemical (vibrational) signatures. This opens up a new opportunity to create inexpensive high-throughput analytical systems for biochemical detection.
Implementation of Ada protocols on Mil-STD-1553 B data bus
NASA Technical Reports Server (NTRS)
Ruhman, Smil; Rosemberg, Flavia
1986-01-01
Standardization activity of data communication in avionic systems started in 1968 for the purpose of total system integration and the elimination of heavy wire bundles carrying signals between various subassemblies. The growing complexity of avionic systems is straining the capabilities of MIL-STD-1553 B (first issued in 1973), but a much greater challenge to it is posed by Ada, the standard language adopted for real-time, computer embedded-systems. Hardware implementation of Ada communication protocols in a contention/token bus or token ring network is proposed. However, during the transition period when the current command/response multiplex data bus is still flourishing and the development environment for distributed multi-computer Ada systems is as yet lacking, a temporary accomodation of the standard language with the standard bus could be very useful and even highly desirable. By concentrating all status informtion and decisions at the bus controller, it was found to be possible to construct an elegant and efficient harware impelementation of the Ada protocols at the bus interface. This solution is discussed.
Laser Generation of Ultrasound.
1983-02-01
32 24 Tissue Soaked in Water on Tank ... ........ . . . . 34 25 2 Mil Teflon TFE Sample on Tank ... ........... ... 34 26 2 Mil Teflon PFA Sample on...frequency doubled from 1.06 to 0.532 um since more efficient ab- sorption of the laser took place at the latter wavelength. Von Gutfeld focused the...the temperature rise is 10000 C for aluminum but only 300 C for a plastic, since the ab- sorption depth is much larger. This is indeed confirmed by
Zhou, Qingxiang; Lei, Man; Wu, Yalin; Yuan, Yongyong
2017-03-03
Metal-organic framework material has been paid more attention because of its good physical and chemical properties. Nanoscale zero valent iron is also in the center of concern recently. Combination of their merits will give impressive results. Present study firstly synthesized a new magnetic nanomaterial nano-scale zero valent iron-functionalized metal-organic framworks MIL-101 (Fe@MIL-101) by co-precipitation method. The morphology and structure of the as-prepared Fe@MIL-101 were characterized by transmission electron microscopy and X-ray diffraction, etc. The experimental results showed that Fe@MIL-101 earned good adsorption ability to polycyclic aromatic hydrocarbons. The limits of detection of developed magnetic solid phase extraction were all below 0.064μgL -1 and precision can be expressed as relative standard deviation (RSD, %) and which was better than 4.4% (n=6). The real water analysis indicated that the spiked recoveries were satisfied, and Fe@MIL-101 earned excellent reusability. All these demonstrated that Fe@MIL-101 exhibited excellent adsorption capability to polycyclic aromatic hydrocarbons and would be a good adsorbent for development of new monitoring methods for environmental pollutants. Copyright © 2017 Elsevier B.V. All rights reserved.
Mod-5A wind turbine generator program design report. Volume 4: Drawings and specifications, book 1
NASA Astrophysics Data System (ADS)
1984-08-01
The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator is documented. Volume 4 contains the drawings and specifications that were developed in preparation for building the MOD-5A wind turbine generator. This is the first of five books of volume four. It contains structural design criteria, generator step-up transformer specs, specs for design, fabrication and testing of the system, specs for the ground control enclosure, systems specs, slip ring specs, and control system specs.
Mod-5A Wind Turbine Generator Program Design Report. Volume 4: Drawings and Specifications, Book 1
NASA Technical Reports Server (NTRS)
1984-01-01
The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator is documented. Volume 4 contains the drawings and specifications that were developed in preparation for building the MOD-5A wind turbine generator. This is the first of five books of volume four. It contains structural design criteria, generator step-up transformer specs, specs for design, fabrication and testing of the system, specs for the ground control enclosure, systems specs, slip ring specs, and control system specs.
Classification of Tree Species in Overstorey Canopy of Subtropical Forest Using QuickBird Images.
Lin, Chinsu; Popescu, Sorin C; Thomson, Gavin; Tsogt, Khongor; Chang, Chein-I
2015-01-01
This paper proposes a supervised classification scheme to identify 40 tree species (2 coniferous, 38 broadleaf) belonging to 22 families and 36 genera in high spatial resolution QuickBird multispectral images (HMS). Overall kappa coefficient (OKC) and species conditional kappa coefficients (SCKC) were used to evaluate classification performance in training samples and estimate accuracy and uncertainty in test samples. Baseline classification performance using HMS images and vegetation index (VI) images were evaluated with an OKC value of 0.58 and 0.48 respectively, but performance improved significantly (up to 0.99) when used in combination with an HMS spectral-spatial texture image (SpecTex). One of the 40 species had very high conditional kappa coefficient performance (SCKC ≥ 0.95) using 4-band HMS and 5-band VIs images, but, only five species had lower performance (0.68 ≤ SCKC ≤ 0.94) using the SpecTex images. When SpecTex images were combined with a Visible Atmospherically Resistant Index (VARI), there was a significant improvement in performance in the training samples. The same level of improvement could not be replicated in the test samples indicating that a high degree of uncertainty exists in species classification accuracy which may be due to individual tree crown density, leaf greenness (inter-canopy gaps), and noise in the background environment (intra-canopy gaps). These factors increase uncertainty in the spectral texture features and therefore represent potential problems when using pixel-based classification techniques for multi-species classification.
Four new species of pholcine spiders (Araneae: Pholcidae) from Southeast Asia.
Yao, Zhiyuan; Li, Shuqiang; Jäger, Peter
2014-04-30
Four new species belonging to four genera of the subfamily Pholcinae are reported from Southeast Asia: Belisana protumida spec. nov. (male, female), Khorata bayeri spec. nov. (male), Pholcus schawalleri spec. nov. (male), and Uthina khaosokensis spec. nov. (male).
NASA Astrophysics Data System (ADS)
Bobkov, S. G.; Serdin, O. V.; Arkhangelskiy, A. I.; Arkhangelskaja, I. V.; Suchkov, S. I.; Topchiev, N. P.
The problem of electronic component unification at the different levels (circuits, interfaces, hardware and software) used in space industry is considered. The task of computer systems for space purposes developing is discussed by example of scientific data acquisition system for space project GAMMA-400. The basic characteristics of high reliable and fault tolerant chips developed by SRISA RAS for space applicable computational systems are given. To reduce power consumption and enhance data reliability, embedded system interconnect made hierarchical: upper level is Serial RapidIO 1x or 4x with rate transfer 1.25 Gbaud; next level - SpaceWire with rate transfer up to 400 Mbaud and lower level - MIL-STD-1553B and RS232/RS485. The Ethernet 10/100 is technology interface and provided connection with the previously released modules too. Systems interconnection allows creating different redundancy systems. Designers can develop heterogeneous systems that employ the peer-to-peer networking performance of Serial RapidIO using multiprocessor clusters interconnected by SpaceWire.
MultiSpec: A Desktop and Online Geospatial Image Data Processing Tool
NASA Astrophysics Data System (ADS)
Biehl, L. L.; Hsu, W. K.; Maud, A. R. M.; Yeh, T. T.
2017-12-01
MultiSpec is an easy to learn and use, freeware image processing tool for interactively analyzing a broad spectrum of geospatial image data, with capabilities such as image display, unsupervised and supervised classification, feature extraction, feature enhancement, and several other functions. Originally developed for Macintosh and Windows desktop computers, it has a community of several thousand users worldwide, including researchers and educators, as a practical and robust solution for analyzing multispectral and hyperspectral remote sensing data in several different file formats. More recently MultiSpec was adapted to run in the HUBzero collaboration platform so that it can be used within a web browser, allowing new user communities to be engaged through science gateways. MultiSpec Online has also been extended to interoperate with other components (e.g., data management) in HUBzero through integration with the geospatial data building blocks (GABBs) project. This integration enables a user to directly launch MultiSpec Online from data that is stored and/or shared in a HUBzero gateway and to save output data from MultiSpec Online to hub storage, allowing data sharing and multi-step workflows without having to move data between different systems. MultiSpec has also been used in K-12 classes for which one example is the GLOBE program (www.globe.gov) and in outreach material such as that provided by the USGS (eros.usgs.gov/educational-activities). MultiSpec Online now provides teachers with another way to use MultiSpec without having to install the desktop tool. Recently MultiSpec Online was used in a geospatial data session with 30-35 middle school students at the Turned Onto Technology and Leadership (TOTAL) Camp in the summers of 2016 and 2017 at Purdue University. The students worked on a flood mapping exercise using Landsat 5 data to learn about land remote sensing using supervised classification techniques. Online documentation is available for MultiSpec (engineering.purdue.edu/ biehl/MultiSpec/) including a reference manual and several tutorials allowing young high-school students through research faculty to learn the basic functions in MultiSpec. Some of the tutorials have been translated to other languages by MultiSpec users.
Mod-5A wind turbine generator program design report. Volume 4: Drawings and specifications, book 2
NASA Technical Reports Server (NTRS)
1984-01-01
The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator is documented. There are four volumes. This volume contains the drawings and specifications that were developed in preparation for building the MOD-5A wind turbine generator. This is the second book of volume four. Some of the items it contains are specs for the emergency shutdown panel, specs for the simulator software, simulator hardware specs, site operator terminal requirements, control data system requirements, software project management plan, elastomeric teeter bearing requirement specs, specs for the controls electronic cabinet, and specs for bolt pretensioning.
NASA Astrophysics Data System (ADS)
Pašava, Jan; Tornos, Fernando; Chrastný, Vladislav
2014-10-01
We studied zinc and sulfur isotopes and the chemical composition of sphalerite samples from Picos de Europa (Aliva mine) and sphalerite and hydrozincite samples from La Florida mine, two carbonate-hosted Mississippi Valley-type (MVT) deposits located in northern Spain; despite being close, they are hosted in carbonatic rocks of different ages, Lower Carboniferous and Lower Cretaceous, respectively. The two generations of sphalerite at Picos de Europa show different δ66Zn values (stage 1 sphalerite +0.24 per mil and stage 2 sphalerite from -0.75 to +0.08 per mil). Both generations also differ in the sulfur isotope composition (stage 1 has δ34S = +6.6 and stage 2 has δ34S = -0.9 to +2.9 per mil) and the chemical composition (stage 1 sphalerite, compared to stage 2 sphalerite, is significantly enriched in Pb, As, Mn, Sb, slightly enriched in Ag, Ni, and Cu and depleted in Co, Ga, Tl, Te, Ge, and Sn). We suggest that Zn isotope fractionation was controlled predominantly by pH and T changes. High Zn isotope values reflect rapid precipitation of sphalerite from higher-temperature acidic fluids that carried Zn mostly as chloride species after interaction with carbonate rocks while lower Zn isotope values most likely resulted from a longer precipitation process from fluid at higher pH and decreasing T that carried dominantly Zn sulfide species. At La Florida, sphalerite samples show light 66Zn-depleted signatures with δ66Zn values from -0.80 to -0.01 per mil (mostly between -0.80 and -0.24 per mil) and δ34S values from +10.7 to +15.7 per mil without any relationship between the δ66Zn and δ34S values. Here, the variation in Zn isotope values is interpreted as related to mixing of fluids from two reservoirs. The Zn was carried by a single deep-seated and higher T (~250-320 °C) fluid, and precipitation took place after mixing with a connate S-rich fluid in a system with mH2S > mZn2+ as a result of change in pH, T, and Zn predominant species. The light δ66Zn accompanied by heavy δ34S values resulted from fractionation of Zn aqueous sulfides at near-neutral pH and decreasing T. Hydrozincite samples show much heavier δ66Zn values (+0.21 to +0.33 per mil), consistent with fractionation during supergene processes.
NASA Astrophysics Data System (ADS)
Kim, M.; Lee, I.; Lee, J.; Park, B.; Mayer, B.; Kaufman, A. J.; Park, S.; Kim, G.; Lee, K.
2008-12-01
Isotopic compositions of sulfur (δ34S) and oxygen (δ18O) were measured for the sulfate of the fresh water near the King Sejong Station, King George Island, Antarctica. Sejong station is located in the Barton peninsular of the King George Island. The geology around King Sejong station mainly composed of basalt-andesite, quart monzodiorite, and granodiorite. Lapilli tuff, conglomerate, sandstone, and siltstone occur along the southern and eastern shore of the Barton peninsula. Lapilli tuff also occurs on the highland located on southeastern part of the Barton peninsula. The δ34S values of sulfate extracted from fresh water samples at King Sejong Station range from 13.7 to 16.3 per mil excluding 1 sample. These sulfur values are very narrow in their range compared with those from anthropogenic sources. These sulfur values are 5 to 7 per mil lower than those of typical present seawater. Considering the rocks occurring near the King Sejong station, these sulfur isotopic values do not seem to be related to any evaporites of certain age. In Antarctic region the natural source of sulfate dissolved in water could be originated from marine biogenic source (DMS), sea-salt, volcanic source, or other continental sources. Most of the δ34S values of sulfate at King Sejong station seems to indicate the dominance of marine biogenic origin for the source of sulfur. The δ18O values of sulfate extracted from fresh water samples at King Sejong Station range from 1.9 to 6.4 per mil excluding 1 sample. These oxygen isotope values are lower than those of the sulfate in the present seawater by 6 per mil. However, both sulfur and oxygen isotope values strongly represent the influence of the seawater sulfate. One sample have 2.6 and -1.1 per mil in its δ34S and δ18O values, respectively, that are quite different from the isotopic values of other samples. This sample was collected in the highland far from the King Sejong station. Therefore this sample might reflect the composition of rather pure precipitation not affected by seawater sulfate. The atmospheric deposition might have been the major source of dissolved sulfate but it is not clear whether the source materials are from natural and/or anthropogenic origin.
High temperature (Al2O3) insulation and light weight conductors
NASA Technical Reports Server (NTRS)
Walker, H.
1981-01-01
The of an aluminum conductor with an aluminum oxide insulation film was investigated. Aluminum oxide insulated wire or strip (with a melting point of 2050 C) is unique for applications in the electronic, missile, atomic reactor, aerospace, and aircraft industries. The oxide film is highly flexible, suitable for all windings of any size and shape of coil (magnetic). Briefly touched upon are the ultraviolet, proton gamma radiation uses, as well as high vacuum and cryogenic applications. Since the film is inorganic and chemically inert, it does not age or deteriorate in storage and has good dielectric properties (1000 volts per mil).
High temperature (Al2O3) insulation and light weight conductors
NASA Astrophysics Data System (ADS)
Walker, H.
The of an aluminum conductor with an aluminum oxide insulation film was investigated. Aluminum oxide insulated wire or strip (with a melting point of 2050 C) is unique for applications in the electronic, missile, atomic reactor, aerospace, and aircraft industries. The oxide film is highly flexible, suitable for all windings of any size and shape of coil (magnetic). Briefly touched upon are the ultraviolet, proton gamma radiation uses, as well as high vacuum and cryogenic applications. Since the film is inorganic and chemically inert, it does not age or deteriorate in storage and has good dielectric properties (1000 volts per mil).
NASA Astrophysics Data System (ADS)
Linse, Katrin; Schwabe, Enrico
2018-02-01
While biodiversity patterns of Atlantic deep-sea bivalves and gastropods have served as model taxa for setting global latitudinal and bathymetric hypotheses, less is known on abyssal, amphi-Atlantic molluscan assemblage compositions. The Vema-TRANSIT expedition sampled 17 stations in the Vema Fracture Zone (VFZ) and the Puerto Rico Trench (PRT) by epibenthic sledge. These samples comprised a total of 1333 specimens and 64 morphospecies of the classes Caudofoveata (7 species), Solenogastres (7 spp.), Bivalvia (22 spp.), Gastropoda (24 spp.), and Scaphopoda (4 spp.) while Cephalopoda, Monoplacophora and Polyplacophora were absent. The majority of species was rare with 21 uniques (32.8% of all species) and 10 duplicates (15.6% of all species) and of these 15 (48% of rare/23.4% of all species) morphospecies were singletons and 8 (25.8% of rare/12.5% of all species) morphospecies were doubletons. Overall bivalves (686 specimens) were most abundant, followed by scaphopods (314 spec.), while solenogastres (180 spec.), caudofoveates (86 spec.) and gastropods (67 spec.) were less abundant. The abyssal macro-molluscan species composition did not vary significantly between the eastern and western Atlantic sides of the VFZ while abundances standardized to 1000 m2 trawled area were higher on the eastern side. The abyssal PRT stations resembled the VFZ ones in species composition and abundances, in the latter the eastern VFZ. The hadal PRT differed in species composition from the abyssal VFZ and PRT and abundances were similarly low like the western VFZ. The Mid-Atlantic Ridge appeared not to be a barrier for the dispersal of the mostly lecitotrophic or plankotrophic larval stages of the reported molluscan species in this study.
NASA Technical Reports Server (NTRS)
1999-01-01
Analytical Spectral Devices was able to commercialize the "engine" of SeaSpec. The Dual CCD developed for SeaSpec is used in our FieldSpecO Dual UV/VNIR/CCD. This product is very popular for coastal research. It allows for a small suitcase sized spectrometer to be placed in a boat and the attached fiber optic cable can be lowered 30 feet below the surface allowing researchers to perform the same studies as SeaSpec just not at the deep-water depths. Most of the people who inquire about SeaSpec end up purchasing a FieldSpec Dual CCD.SeaSpec was designed to withstand harsh marine environments and depths up to 200 m. While it meets these requirements it is the only instrument of its kind and we consider it a prototype. The first version was released in April 1997. It was tested, we made modification and returned the product in March 1998.
Sun, Zhengjuan; Liu, Yali; Li, Yuanfang
2015-03-15
A novel and rapid spectrofluorometry method for the recognition of 6-mercaptopurine (6-MP) has been developed based on luminescent metal-organic frameworks Fe-MIL-88NH2 as fluorescent probe. The strong fluorescence of Fe-MIL-88NH2 at 430 nm could be quenched by 6-MP directly, and the Fe-MIL-88NH2 shows high selectivity for 6-MP compared to other thiol-containing amino acids such as homocysteine (Hcy), cysteine (Cys), glutathione (GSH), etc. Under optimal conditions, the relative fluorescence intensity was linearly proportional to the concentration of 6-MP in the range of 5-600 μM with the detection limit at 1.17 μM (S/N=3). Furthermore, the present approach has been successfully applied to the determination of 6-MP in human serum samples. The possible fluorescence quenching mechanism has also been investigated, where it is revealed that the quenching was attributed to competition of absorption of the light source energy as well as electron transfer between Fe-MIL-88NH2 and 6-MP. Copyright © 2014 Elsevier B.V. All rights reserved.
Relative quantification of biomarkers using mixed-isotope labeling coupled with MS
Chapman, Heidi M; Schutt, Katherine L; Dieter, Emily M; Lamos, Shane M
2013-01-01
The identification and quantification of important biomarkers is a critical first step in the elucidation of biological systems. Biomarkers take many forms as cellular responses to stimuli and can be manifested during transcription, translation, and/or metabolic processing. Increasingly, researchers have relied upon mixed-isotope labeling (MIL) coupled with MS to perform relative quantification of biomarkers between two or more biological samples. MIL effectively tags biomarkers of interest for ease of identification and quantification within the mass spectrometer by using isotopic labels that introduce a heavy and light form of the tag. In addition to MIL coupled with MS, a number of other approaches have been used to quantify biomarkers including protein gel staining, enzymatic labeling, metabolic labeling, and several label-free approaches that generate quantitative data from the MS signal response. This review focuses on MIL techniques coupled with MS for the quantification of protein and small-molecule biomarkers. PMID:23157360
Babu, K Pradeep; Keerthi, V Naga; Madathody, Deepika; Prasanna, A Laxmi; Gopinath, Vidhya; Kumar, M Senthil; Kumar, A Nanda
2016-05-01
Recent metallurgical research and advancement in material science has benefited orthodontists in the selection of an appropriate wire size and alloy type, which is necessary to provide an optimum and predictable treatment results. The purpose of the study was to clinically evaluate and compare the surface characteristics of 16 x 22 stainless steel, Titanium molybdenum alloy, timolium, and titanium-niobium before and after placing them in a patient's mouth for 3 months using a scanning electron microscope (SEM). The total sample size was 40, which were divided into four groups (group 1 - stainless steel wires, 10 samples, group 2 - TMA wires, 10 samples, group 3 - timolium wires, 10 samples, and group 4 - titanium-niobium wires, 10 samples), and these were further subdivided into 5 each. The first subgroup of five samples was placed in the patient's mouth and was evaluated under SEM, and another subgroup of five samples was directly subjected to the SEM. Scanning electron microscopic evaluation of surface characteristics of unused 16 x 22 rectangular stainless steel wire under 500 x magnification showed an overall smooth surface. Stainless steel wire samples placed in the patient's mouth showed black hazy patches, which may be interoperated as areas of stress. TMA unused wires showed multiple small voids of areas and small craters with fewer elevated regions. The TMA wire samples placed in the patient's mouth showed black hazy patches and prominent ridges, making the wire rougher. Timolium unused archwires showed heavy roughness and voids, whereas wires tested in the patient's mouth showed homogeneous distribution of deep cracks and craters. Unused titanium-niobium archwires showed uniform prominent striations and ridges with occasional voids, whereas wires used in the patient's mouth showed prominent huge voids that could be interpreted as maximum stress areas. Stainless steel (group 1) used and unused wires showed smooth surface characteristics when compared with all the other three groups followed by timolium, which was superior to titanium-niobium wires and TMA wires. Timolium wires are superior to titanium-niobium wires and TMA wires.
Xiao, Zuowei; He, Man; Chen, Beibei; Hu, Bin
2016-08-15
In this work, the metal-organic frameworks (MOFs), MIL-101-Cr-NH2 was synthesized via a direct hydrothermal method, and a polydimethylsiloxane (PDMS)/MIL-101-Cr-NH2 coated stir bar was prepared by sol-gel technique. Good reproducibility was obtained for the preparation of PDMS/MIL-101-Cr-NH2 coated stir bar with the relative standard deviations (RSDs) ranging from 3.7 to 5.2% (n=7) in one batch, and from 5.4 to 9.2% (n=7) among different batches. With the high surface area and rich benzene ring structure of MIL-101-Cr-NH2, the prepared PDMS/MIL-101-Cr-NH2 coated stir bar presented higher extraction efficiency for target organophosphorus pesticides (OPPs, including phorate, diazinon, malathion, fenthion, quinalphos and ethion) over PDMS coated stir bar. Based on it, a new method of PDMS/MIL-101-Cr-NH2 coated stir bar sorptive extraction (SBSE) coupled to gas chromatography-flame photometric detection (GC-FPD) was proposed for the determination of six OPPs in environmental water samples. The operation parameters affecting the extraction efficiency of SBSE, including extraction time, stirring rate, desorption time and ionic strength, were investigated. Under the optimal conditions, the limits of detection (S/N=3) were found to be in the range of 0.043-0.085μgL(-1) for the six target OPPs, and the linear range was 0.5-100μgL(-1) for malathion and 0.2-100μgL(-1) for other five OPPs. The RSDs of the proposed method evaluated at 1µgL(-1) for each OPP were in the range of 5.9-8.7% (intra-day, n=7) and 6.1-10.7% (inter-day, n=5), respectively. The enrichment factors were varied from 110 to 151-fold (theoretical enrichment factor was 200-fold). The proposed method was applied to the analysis of OPPs in East Lake and pond water samples with recoveries in the range of 89.3-115% and 80.0-113% for the spiked East Lake and pond water samples, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.
A Survey on the Temporal and Spatial Distribution of Perchlorate in the Potomac River
Samples of river water and treated drinking water were obtained from eight sites along the Potomac River between western Maryland and Washington DC. Samples were collected each month from October 2007 to September 2008 and analyzed for perchlorate by ion chromatography/mass spec...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kornberg, H.A.; Cline, J.F.
Twenty-four sputum samples were taken from persons working in the vicinity of separation stacks from which radioactive particles are discharged. No evidence of specs'' were sound by radioautography of the sputum plates. Six samples were reset for longer exposure times in an attempt to detect particles of very low activity. Negative results were obtained. 1 tab.
Lei, Yun; Chen, Beibei; You, Linna; He, Man; Hu, Bin
2017-12-01
Polydimethylsiloxane (PDMS)/MIL-100(Fe) coated stir bar was prepared by sol gel technique, and good preparation reproducibility was achieved with relative standard deviations (RSDs) ranging from 2.6% to 7.5% (n=7) and 3.6% to 10.8% (n=7) for bar-to-bar and batch-to-batch, respectively. Compared with commercial PDMS coated stir bar (Gerstel) and PEG coated stir bar (Gerstel), the prepared PDMS/MIL-100(Fe) stir bar showed better extraction efficiency for target triazines compounds. It also exhibited relatively fast extraction/desorption kinetics and long lifespan. Based on it, a method of PDMS/MIL-100(Fe) coated stir bar sorptive extraction (SBSE)-high performance liquid chromatography-ultraviolet detector (HPLC-UV) was developed for the determination of six triazines (simazine, atrazine, prometon, ametryn, prometryne and prebane) in environmental water samples. Several parameters affecting SBSE of six target triazines including extraction time, stirring rate, sample pH, ionic strength, desorption solvent and desorption time were investigated. Under the optimal experimental conditions, the limits of detection (LODs, S/N=3) were found to be in the range of 0.021-0.079μgL -1 . The repeatability RSDs were in the range of 2.3-6.3% (n=7, c=0.5μgL -1 ) and the enrichment factors (EFs) ranged from 51.1 to 102-fold (theoretical EF was 200-fold). The proposed method was applied to the analysis of target triazines in environmental water samples, with recoveries of 98.0-118% and 94.0-107% for spiked East Lake water and local pond water samples, respectively. Copyright © 2017. Published by Elsevier B.V.
The new materials science diffractometer STRESS-SPEC at FRM-II
NASA Astrophysics Data System (ADS)
Hofmann, M.; Schneider, R.; Seidl, G. A.; Rebelo-Kornmeier, J.; Wimpory, R. C.; Garbe, U.; Brokmeier, H.-G.
2006-11-01
In response to the development of new materials and the application of materials and components in new technologies the direct measurement, calculation and evaluation of textures and residual stresses has gained worldwide significance in recent years. In order to cater for the development of these analytical techniques the Materials Science Diffractometer STRESS-SPEC at FRM-II is designed to be equally applied to texture or residual stress analysis by virtue of its flexible configuration and the high neutron flux at the sample position. The instrument is now available for routine operation and here we present details of first experiments and instrument performance.
Metal organic frameworks as a drug delivery system for flurbiprofen.
Al Haydar, Muder; Abid, Hussein Rasool; Sunderland, Bruce; Wang, Shaobin
2017-01-01
Metal organic frameworks (MOFs) have attracted more attention in the last decade because of a suitable pore size, large surface area, and high pore volume. Developing biocompatible MOFs such as the MIL family as a drug delivery system is possible. Flurbiprofen (FBP), a nonsteroidal anti-inflammatory agent, is practically insoluble in aqueous solution, and, therefore, needs suitable drug delivery systems. Different biocompatible MOFs such as Ca-MOF and Fe-MILs (53, 100, and 101) were synthesized and employed for FBP delivery. A sample of 50 mg of each MOF was mixed and stirred for 24 h with 10 mL of 5 mg FBP in acetonitrile (40%) in a sealed container. The supernatant of the mixture after centrifuging was analyzed by high-performance liquid chromatography to determine the loaded quantity of FBP on the MOF. The overnight-dried solid material after centrifuging the mixture was analyzed for loading percent using X-ray diffraction, Fourier-transform infrared spectroscopy, scanning electron microscopy, nuclear magnetic resonance, and FBP release profile. The loading values of FBP were achieved at 10.0%±1%, 20%±0.8%, 37%±2.3%, and 46%±3.1% on Ca-MOF, Fe-MIL-53, Fe-MIL-101, and Fe-MIL-100, respectively. The FBP release profiles were investigated in a phosphate buffer solution at pH 7.4. The total release of the FBP after 2 days was obtained at 72.9, 75.2, 78.3, and 90.3% for Ca-MOF, Fe-MIL-100, Fe-MIL-53, and Fe-MIL-101, respectively. The MOFs are shown to be a promising drug delivery option for FBP with a significant loading percent and relatively prolonged drug release.
Emaus, Miranda N; Clark, Kevin D; Hinners, Paige; Anderson, Jared L
2018-04-28
Nucleic acid extraction and purification represents a major bottleneck in DNA analysis. Traditional methods for DNA purification often require reagents that may inhibit quantitative polymerase chain reaction (qPCR) if not sufficiently removed from the sample. Approaches that employ magnetic beads may exhibit lower extraction efficiencies due to sedimentation and aggregation. In this study, four hydrophobic magnetic ionic liquids (MILs) were investigated as DNA extraction solvents with the goal of improving DNA enrichment factors and compatibility with downstream bioanalytical techniques. By designing custom qPCR buffers, we directly incorporated DNA-enriched MILs including trihexyl(tetradecyl)phosphonium tris(hexafluoroacetylaceto)nickelate(II) ([P 6,6,6,14 + ][Ni(hfacac) 3 - ]), [P 6,6,6,14 + ] tris(hexafluoroacetylaceto)colbaltate(II) ([Co(hfacac) 3 - ]), [P 6,6,6,14 + ] tris(hexafluoroacetylaceto)manganate(II) ([Mn(hfacac) 3 - ]), or [P 6,6,6,14 + ] tetrakis(hexafluoroacetylaceto)dysprosate(III) ([Dy(hfacac) 4 - ]) into reaction systems, thereby circumventing the need for time-consuming DNA recovery steps. Incorporating MILs into the reaction buffer did not significantly impact the amplification efficiency of the reaction (91.1%). High enrichment factors were achieved using the [P 6,6,6,14 + ][Ni(hfacac) 3 - ] MIL for the extraction of single-stranded and double-stranded DNA with extraction times as short as 2 min. When compared to a commercial magnetic bead-based platform, the [P 6,6,6,14 + ][Ni(hfacac) 3 - ] MIL was capable of producing higher enrichment factors for single-stranded DNA and similar enrichment factors for double-stranded DNA. The MIL-based method was applied for the extraction and direct qPCR amplification of mutation prone-KRAS oncogene fragment in plasma samples. Graphical abstract Magnetic ionic liquid solvents are shown to preconcentrate sufficient KRAS DNA template from an aqueous solution in as short as 2 min without using chaotropic salts or toxic organic solvents. By using custom-designed qPCR buffers, DNA can be directly amplified and quantified from four MILs examined in this study.
When Will It Be... USNO Seasons and Apsides Calculator
NASA Astrophysics Data System (ADS)
Chizek Frouard, Malynda; Bartlett, Jennifer Lynn
2018-01-01
The turning of the Earth’s seasons (solstices and equinoxes) and apsides (perihelions and aphelions) are times often used in observational astronomy and also of interest to the public. To avoid tedious calculations, the U.S. Naval Observatory (USNO) has developed an on-line interactive calculator, Earth’s Seasons and Apsides to provide information about events between 1600 and 2200. The new data service uses an Application Programming Interface (API), which returns values in JavaScript Object Notation (JSON) that can be incorporated into third-party websites or applications. For a requested year, the Earth’s Seasons and Apsides API provides the Gregorian calendar date and time of the Vernal Equinox, Summer Solstice, Autumnal Equinox, Winter Solstice, Aphelion, and Perihelion. The user may specify the time zone for their results, including the optional addition of U.S. daylight saving time for years after 1966.On-line documentation for using the API-enabled Earth’s Seasons and Apsides is available, including sample calls (http://aa.usno.navy.mil/data/docs/api.php). A traditional forms-based interface is available as well (http://aa.usno.navy.mil/data/docs/EarthSeasons.php). This data service replaces the popular Earth's Seasons: Equinoxes, Solstices, Perihelion, and Aphelion page that provided a static list of events for 2000–2025. The USNO also provides API-enabled data services for Complete Sun and Moon Data for One Day (http://aa.usno.navy.mil/data/docs/RS_OneDay.php), Dates of the Primary Phases of the Moon (http://aa.usno.navy.mil/data/docs/MoonPhase.php), Selected Christian Observances (http://aa.usno.navy.mil/data/docs/easter.php), Selected Islamic Observances (http://aa.usno.navy.mil/data/docs/islamic.php), Selected Jewish Observances (http://aa.usno.navy.mil/data/docs/passover.php), Julian Date Conversion (http://aa.usno.navy.mil/data/docs/JulianDate.php), and Sidereal Time (http://aa.usno.navy.mil/data/docs/siderealtime.php) as well as its Solar Eclipse Computer (http://aa.usno.navy.mil/data/docs/SolarEclipses.php).
The petrology and geochemistry of Miller Range 05035: A new lunar gabbroic meteorite
NASA Astrophysics Data System (ADS)
Joy, K. H.; Crawford, I. A.; Anand, M.; Greenwood, R. C.; Franchi, I. A.; Russell, S. S.
2008-08-01
Miller Range (MIL) 05035 is a lunar gabbroic meteorite. The mineralogy, Fe/Mn ratios in olivine and pyroxene, bulk-rock chemical composition and the bulk oxygen isotope values (δ 17O = 2.86-2.97‰ and δ 18O = 5.47-5.71‰) are similar to those of other mare basalts, and are taken as supporting evidence for a lunar origin for this meteorite. The sample is dominated by pyroxene grains (54-61% by area mode of thin section) along with large plagioclase feldspar (25-36% by mode) and accessory quartz, ilmenite, spinel, apatite and troilite. The bulk-rock major element composition of MIL 05035 indicates that the sample has a very low-Ti (VLT) to low-Ti lunar heritage (we measure bulk TiO 2 to be 0.9 Wt.%) and has low bulk incompatible trace element (ITE) concentrations, akin to samples from the VLT mare basalt suite. To account for these geochemical characteristics we hypothesize that MIL 05035's parental melt was derived from a mantle region dominated by early cumulates of the magma ocean (comprised principally of olivine and orthopyroxene). MIL 05035 is likely launch paired with the Asuka-881757 and Yamato-793169 basaltic lunar meteorites and the basaltic regolith breccia MET 01210. This group of meteorites (Y/A/M/M) therefore may be a part of a stratigraphic column consisting of an upper regolith environment underlain by a coarsening downwards basalt lava flow.
NASA Astrophysics Data System (ADS)
Madaras, Eric I.; Anastasi, Robert F.; Smith, Stephen W.; Seebo, Jeffrey P.; Walker, James L.; Lomness, Janice K.; Hintze, Paul E.; Kammerer, Catherine C.; Winfree, William P.; Russell, Richard W.
2008-02-01
There is currently no method for detecting corrosion under Shuttle tiles except for the expensive process of tile removal and replacement; hence NASA is investigating new NDE methods for detecting hidden corrosion. Time domain terahertz radiation has been applied to corrosion detection under tiles in samples ranging from small lab samples to a Shuttle with positive results. Terahertz imaging methods have been able to detect corrosion at thicknesses of 5 mils or greater under 1" thick Shuttle tiles and 7-12 mils or greater under 2" thick Shuttle tiles.
NASA Technical Reports Server (NTRS)
Madaras, Eric I.; Anastasi, Robert F.; Smith, Stephen W.; Seebo, Jeffrey P.; Walker, James L.; Lomness, Janice K.; Hintze, Paul E.; Kammerer, Catherine C.; Winfree, William P.; Russell, Richard W.
2007-01-01
There is currently no method for detecting corrosion under Shuttle tiles except for the expensive process of tile removal and replacement; hence NASA is investigating new NDE methods for detecting hidden corrosion. Time domain terahertz radiation has been applied to corrosion detection under tiles in samples ranging from small lab samples to a Shuttle with positive results. Terahertz imaging methods have been able to detect corrosion at thicknesses of 5 mils or greater under 1" thick Shuttle tiles and 7-12 mils or greater under 2" thick Shuttle tiles.
Xu, Xiao-Yu; Yan, Bing
2016-04-28
A pH sensor is fabricated via a reaction between an Al(III) salt and 2-aminoterephthalic acid in DMF which leads to a MOF (Al-MIL-101-NH2) with free amino groups. The Al-MIL-101-NH2 samples show good luminescence and an intact structure in aqueous solutions with pH ranging from 4.0 to 7.7. Given its exceptional stability and pH-dependent fluorescence intensity, Al-MIL-101-NH2 has been applied to fluorescent pH sensing. Significantly, in the whole experimental pH range (4.0-7.7), the fluorescence intensity almost increases with increasing pH (R(2) = 0.99688) which can be rationalized using a linear equation: I = 2.33 pH + 26.04. In addition, error analysis and cycling experiments have demonstrated the accuracy and utilizability of the sensor. In practical applications (PBS and lake water), Al-MIL-101-NH2 also manifests its analytical efficiency in pH sensing. And the samples can be easily isolated from an aqueous solution by incorporating Fe3O4 nanoparticles. Moreover, the possible sensing mechanism based on amino protonation is discussed in detail. This work is on of the few cases for integrated pH sensing systems in aqueous solution based on luminescent MOFs.
Zhang, Shuaihua; Yang, Qian; Li, Zhi; Wang, Wenjin; Zang, Xiaohuan; Wang, Chun; Wang, Zhi
2018-10-15
A hybrid composite featuring an iron-based metal-organic framework Material of Institute Lavoisier-88(Fe) and graphene oxide (MIL-88(Fe)/GO) was synthesized and used as the solid-phase microextraction (SPME) coating. The SPME fiber was prepared by covalent bonding of the MIL-88(Fe)/GO composite onto the stainless steel substrate. The fiber had a good durability and allowed >100 replicate extractions. The developed method, which combined the MIL-88(Fe)/GO coated fiber based SPME with gas chromatography-flame ionization detection (GC-FID), achieved low limits of detection (0.5-2.0 ng g -1 , S/N = 3) and good linearity (r 2 > 0.994) for the phthalic acid esters (PAEs) from various vegetable oil samples. The repeatability and fiber-to-fiber reproducibility were in the range of 4.0-9.1% and 5.7-11.4%, respectively. The method was successfully applied to the analysis of PAEs from vegetable oil samples with good recoveries (83.1-104.1%) and satisfactory precisions (RSDs < 10.5%), indicating that the MIL-88(Fe)/GO hybrid composite is a good coating material for the SPME of PAEs. Copyright © 2018 Elsevier Ltd. All rights reserved.
He, Xi; Yang, Wei; Li, Sijia; Liu, Yu; Hu, Baichun; Wang, Ting; Hou, Xiaohong
2018-01-24
An amino-functionalized magnetic framework composite of type Fe 3 O 4 -NH 2 @MIL-101(Cr) was synthesized using a solvothermal method. The material was characterized by scanning electron microscopy, X-ray diffraction, Fourier transform infrared spectroscopy, nitrogen adsorption, and magnetometry. The composite combines the advantages of amino-modified Fe 3 O 4 and MIL-101(Cr). The presence of amino groups facilitates the fairly specific adsorption of pyrethroids. The composite was employed as a sorbent for magnetic solid phase extraction of five pyrethroids from environmental water samples. Following desorption with acidified acetone, the pyrethroids were quantified by gas chromatography with electron capture detection. The detection limits for bifenthrin, fenpropathrin, λ-cyhalothrin, permethrin, and deltamethrin range from 5 to 9 pg·mL -1 . The method is rapid, accurate, and highly sensitive. The molecular interactions and free binding energies between MIL-101(Cr) and the five pyrethroids were calculated by means of molecular docking. Graphical abstract A novel functionalized magnetic framework composite of type Fe 3 O 4 -NH 2 @MIL-101(Cr) was synthesized. It was applied as a sorbent for magnetic solid phase extraction of pyrethroids prior to their quantitation by gas chromatography with electron capture detection. The molecular interactions of analytes and MIL-101(Cr) were studied.
Chen, Xiangrui; Gao, Shan; Liu, Weiwei; Song, Weibo; Al-Rasheid, Khaled A S; Warren, Alan
2012-03-01
The morphology of three marine colepid ciliates, Nolandia sinica spec. nov., Apocoleps caoi spec. nov. and Tiarina fusa (Claparède & Lachmann, 1858) Bergh, 1881, isolated from Chinese coastal waters, was investigated. N. sinica spec. nov. may be separated from its congeners by the structure of its armour plates, each of which may have up to five reniform windows. A. caoi spec. nov. is characterized by its large body with broad anterior end and by having 10-12 long, sharp posterior spines. New data and an improved diagnosis are supplied for Tiarina fusa (Claparède & Lachmann, 1858) Bergh, 1881, which has a spindle-shaped body, about 16 ciliary rows and a single adoral organelle. Sequence similarities with other available colepid species were determined.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zamora, Richard; Voter, Arthur; Uberuaga, Bla
2017-10-23
The SpecTAD software represents a refactoring of the Temperature Accelerated Dynamics (TAD2) code authored by Arthur F. Voter and Blas P. Uberuaga (LA-CC-02-05). SpecTAD extends the capabilities of TAD2, by providing algorithms for both temporal and spatial parallelism. The novel algorithms for temporal parallelism include both speculation and replication based techniques. SpecTAD also offers the optional capability to dynamically link to the open-source LAMMPS package.
A simple homogeneous model for regular and irregular metallic wire media samples
NASA Astrophysics Data System (ADS)
Kosulnikov, S. Y.; Mirmoosa, M. S.; Simovski, C. R.
2018-02-01
To simplify the solution of electromagnetic problems with wire media samples, it is reasonable to treat them as the samples of a homogeneous material without spatial dispersion. The account of spatial dispersion implies additional boundary conditions and makes the solution of boundary problems difficult especially if the sample is not an infinitely extended layer. Moreover, for a novel type of wire media - arrays of randomly tilted wires - a spatially dispersive model has not been developed. Here, we introduce a simplistic heuristic model of wire media samples shaped as bricks. Our model covers WM of both regularly and irregularly stretched wires.
MilQuant: a free, generic software tool for isobaric tagging-based quantitation.
Zou, Xiao; Zhao, Minzhi; Shen, Hongyan; Zhao, Xuyang; Tong, Yuanpeng; Wang, Qingsong; Wei, Shicheng; Ji, Jianguo
2012-09-18
Isobaric tagging techniques such as iTRAQ and TMT are widely used in quantitative proteomics and especially useful for samples that demand in vitro labeling. Due to diversity in choices of MS acquisition approaches, identification algorithms, and relative abundance deduction strategies, researchers are faced with a plethora of possibilities when it comes to data analysis. However, the lack of generic and flexible software tool often makes it cumbersome for researchers to perform the analysis entirely as desired. In this paper, we present MilQuant, mzXML-based isobaric labeling quantitator, a pipeline of freely available programs that supports native acquisition files produced by all mass spectrometer types and collection approaches currently used in isobaric tagging based MS data collection. Moreover, aside from effective normalization and abundance ratio deduction algorithms, MilQuant exports various intermediate results along each step of the pipeline, making it easy for researchers to customize the analysis. The functionality of MilQuant was demonstrated by four distinct datasets from different laboratories. The compatibility and extendibility of MilQuant makes it a generic and flexible tool that can serve as a full solution to data analysis of isobaric tagging-based quantitation. Copyright © 2012 Elsevier B.V. All rights reserved.
Luo, Xialin; Li, Gongke; Hu, Yufei
2017-04-01
In this work, a novel NH 2 -MIL-53(Al) incorporated poly(styrene-divinylbenzene-methacrylic acid) (poly(St-DVB-MAA)) monolith was prepared via chemical fabrication. Moreover, it has been efficiently applied to the in-tube solid-phase microextraction (SPME) for online coupling with high-performance liquid chromatography (HPLC) to the direct determination of five estrogens in human urine samples. The NH 2 -MIL-53(Al)-polymer monolith was suitable for in-tube SPME owing to its good permeability, high extraction efficiency, chemical stability, good reproducibility and long lifetime. The extraction conditions including extraction solvent, pH of sample solution, flow rate of extraction and desorption, and desorption volume were investigated. Under the optimum conditions, the enrichment factors were 180-304 and saturated amounts of extraction were 2326-21393 pmol for estriol, 17β-estradiol, estrone, ethinyl estradiol and progesterone, respectively. The adsorption mechanism was also explored which contributed to its strong extraction to target compounds. The proposed method had low limit of detection (2.0-40ng/L) and good linearity (with R 2 between 0.9908 and 0.9978). Four endogenous estrogens were detected in urine samples and the recoveries of all five analytes were ranged from 75.1-120% with relative standard deviations (RSDs) less than 8.7%. The results showed that the proposed online SPME-HPLC method based on NH 2 -MIL-53(Al)-polymer monolithic column was highly sensitive for directly monitoring trace amount of estrogens in human urine sample. Copyright © 2016 Elsevier B.V. All rights reserved.
Zhang, Jialing; Rector, John; Lin, John Q.; Young, Jonathan H.; Sans, Marta; Katta, Nitesh; Giese, Noah; Yu, Wendong; Nagi, Chandandeep; Suliburk, James; Liu, Jinsong; Bensussan, Alena; DeHoog, Rachel J.; Garza, Kyana Y.; Ludolph, Benjamin; Sorace, Anna G.; Syed, Anum; Zahedivash, Aydin; Milner, Thomas E.; Eberlin, Livia S.
2018-01-01
Conventional methods for histopathologic tissue diagnosis are labor- and time-intensive and can delay decision-making during diagnostic and therapeutic procedures. We report the development of an automated and biocompatible handheld mass spectrometry device for rapid and nondestructive diagnosis of human cancer tissues. The device, named MasSpec Pen, enables controlled and automated delivery of a discrete water droplet to a tissue surface for efficient extraction of biomolecules. We used the MasSpec Pen for ex vivo molecular analysis of 20 human cancer thin tissue sections and 253 human patient tissue samples including normal and cancerous tissues from breast, lung, thyroid, and ovary. The mass spectra obtained presented rich molecular profiles characterized by a variety of potential cancer biomarkers identified as metabolites, lipids, and proteins. Statistical classifiers built from the histologically validated molecular database allowed cancer prediction with high sensitivity (96.4%), specificity (96.2%), and overall accuracy (96.3%), as well as prediction of benign and malignant thyroid tumors and different histologic subtypes of lung cancer. Notably, our classifier allowed accurate diagnosis of cancer in marginal tumor regions presenting mixed histologic composition. Last, we demonstrate that the MasSpec Pen is suited for in vivo cancer diagnosis during surgery performed in tumor-bearing mouse models, without causing any observable tissue harm or stress to the animal. Our results provide evidence that the MasSpec Pen could potentially be used as a clinical and intraoperative technology for ex vivo and in vivo cancer diagnosis. PMID:28878011
Analysis of a MIL-L-27502 lubricant from a gas-turbine engine test by size-exclusion chromatography
NASA Technical Reports Server (NTRS)
Jones, W. R., Jr.; Morales, W.
1983-01-01
Size exclusion chromatography was used to determine the chemical degradation of MIL-L-27502 oil samples from a gas turbine engine test run at a bulk oil temperature of 216 C. Results revealed a progressive loss of primary ester and additive depletion and the formation of higher molecular weight products with time. The high molecular weight products absorbed strongly in the ultraviolet indicating the presence of chromophoric groups.
Comparison of five diagnostic tests for Giardia duodenalis in fecal samples from young dogs.
Uehlinger, Fabienne D; Naqvi, S Ali; Greenwood, Spencer J; McClure, J Trenton; Conboy, Gary; O'Handley, Ryan; Barkema, Herman W
2017-09-15
Five diagnostic tests were compared for the diagnosis of Giardia duodenalis in fecal samples of young dogs. Fecal samples were collected from 136 healthy dogs <1year old and examined using immunofluorescence antibody microscopy (IFA) after sucrose gradient centrifugation, zinc sulfate centrifugal flotation technique (ZSCT), SNAP ® Giardia test, and ProSpecT ® Giardia EZ Microplate assay. In addition, polymerase chain reaction (PCR) of the 16S rRNA gene was performed. Kappa (κ) statistic was calculated to assess diagnostic agreement between the IFA and each test. Using the IFA as the gold standard, the relative sensitivity and specificity of each test were determined. Subsequently, a Bayesian approach was used to estimate the sensitivity and specificity of each test in comparison to the IFA results. Giardia duodenalis was detected in 41% of the samples examined by IFA. The ZSCT resulted in 37% of positive samples, with a relative sensitivity and specificity of 86 and 98%, respectively. The SNAP ® Giardia test was positive in 40% of the samples, with a relative sensitivity and specificity of 91 and 96%, respectively. The ProSpecT ® test was positive in 51% of the samples, with a relative sensitivity and specificity of 100 and 83%, respectively. The relative sensitivity and specificity for PCR were 58 and 56%, respectively, with 55% of samples being PCR-positive. While the sensitivity and specificity estimates of each test in comparison to the IFA changed when using a Bayesian approach, the conclusions remained the same. While the ProSpecT ® test was the most sensitive test in this study, it is not designed for dogs and more costly than the other tests. The SNAP ® Giardia test performed similar to the ZSCT but may be more favorable because it is fast and easy to perform. Performance of the PCR was poor and the benefit of PCR may be in determining genotypes for evaluating zoonotic transfer between dogs and humans. Copyright © 2017 Elsevier B.V. All rights reserved.
Li, Xianjiang; Xing, Jiawei; Chang, Cuilan; Wang, Xin; Bai, Yu; Yan, Xiuping; Liu, Huwei
2014-06-01
MIL-101(Cr) is an excellent metal-organic framework with high surface area and nanoscale cavities, making it promising in solid-phase extraction. Herein, we used MIL-101(Cr) as a solid-phase extraction packing material combined with fast detection of direct analysis in real time mass spectrometry (DART-MS) for the analysis of triazine herbicides. After systematic optimization of the operation parameters, including the gas temperature of DART, the moving speed of the 1D platform, solvent for desorption, amount of MIL-101(Cr) extraction time, eluent volume and salt concentration, this method can realize the simultaneous detection of five kinds of triazine herbicides. The limits of detection were 0.1∼0.2 ng/mL and the linear ranges covered more than two orders of magnitude with the quantitation limits of 0.5∼1 ng/mL. Moreover, the developed method has been applied for the analysis of lake water samples and the recoveries for spiked analytes were in the range of 85∼110%. These results showed that solid-phase extraction with metal-organic frameworks is an efficient sample preparation approach for DART-MS analysis and could find more applications in environmental analysis. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Alternative Test Methods for Electronic Parts
NASA Technical Reports Server (NTRS)
Plante, Jeannette
2004-01-01
It is common practice within NASA to test electronic parts at the manufacturing lot level to demonstrate, statistically, that parts from the lot tested will not fail in service using generic application conditions. The test methods and the generic application conditions used have been developed over the years through cooperation between NASA, DoD, and industry in order to establish a common set of standard practices. These common practices, found in MIL-STD-883, MIL-STD-750, military part specifications, EEE-INST-002, and other guidelines are preferred because they are considered to be effective and repeatable and their results are usually straightforward to interpret. These practices can sometimes be unavailable to some NASA projects due to special application conditions that must be addressed, such as schedule constraints, cost constraints, logistical constraints, or advances in the technology that make the historical standards an inappropriate choice for establishing part performance and reliability. Alternate methods have begun to emerge and to be used by NASA programs to test parts individually or as part of a system, especially when standard lot tests cannot be applied. Four alternate screening methods will be discussed in this paper: Highly accelerated life test (HALT), forward voltage drop tests for evaluating wire-bond integrity, burn-in options during or after highly accelerated stress test (HAST), and board-level qualification.
Qi, Chao; Cai, Qianqian; Zhao, Pan; Jia, Xiuna; Lu, Nan; He, Lu; Hou, Xiaohong
2016-06-03
Metal-organic framework MIL-101(Cr) was successfully used as an efficient sorbent in a vortex-assisted dispersive solid-phase extraction (VA-DSPE) and applied for the determination and the pharmacokinetic of imatinib mesylate in rat plasma by UPLC-MS/MS. In the enrichment of imatinib from rat plasma, the analyte was efficiently adsorbed on MIL-101(Cr) and simply recovered by using initial mobile phase (0.1% formic acid-methanol (6:4 v/v)) as elution solvent. Meanwhile, the protein in the plasma samples was excluded from the porous structure of MIL-101(Cr), leading to direct extraction of drug molecule from protein-rich biological samples without any other pretreatment procedure. After being removed, the supernatant was filtered and directly injected into the UPLC-MS/MS for the analysis of the target. The experimental parameters, including nature of MOFs, amount of MIL-101(Cr), pH value of aqueous solution, extraction time, type and volume of elution solvent, were systematically optimized. After VA-DSPE, chromatographic separation was performed on an ACQUITY UPLC(®) BEH C18 column (2.1mm×100mm, 1.7μm) with a 3min gradient elution using 0.1% formic acid and methanol as mobile phase at a flow rate of 0.3mL/min. The detection was accomplished on a tandem mass spectrometer via an electrospray ionization (ESI) source by multiple reaction monitoring (MRM) in the positive ionization mode. The lower limit of quantification of 1ng/mL was achieved and the mean recovery of the analyte was higher than 81.2%. Moreover, computational simulation was primarily applied to predict the adsorption behavior and revealed the molecular interactions and free binding energies between MIL-101(Cr) and imatinib with the molecular modeling method, providing certain explanation of the adsorption mechanism. The originally established pretreatment and detection method has some merits, such as less solvent consumption, easy operation, higher sensitivity and lower matrix effect. And the MIL-101(Cr) exhibited a potential as an efficient sorbent in the enrichment of the analyte from complex biosamples. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chambers, Robert S.; Neidigk, Matthew A.
Sandia SPECabq is FORTRAN code that defines the user supplied subroutines needed to perform nonlinear viscoelastic analyses in the ABAQUS commercial finite element code based on the Simplified Potential Energy Clock (SPEC) Model. The SPEC model was published in the open literature in 2009. It must be compiled and linked with the ABAQUS libraries under the user supplied subroutine option of the ABAQUS executable script. The subroutine is used to analyze the thermomechanical behavior of isotropic polymers predicting things like how a polymer may undergo stress or volume relaxation under different temperature and loading environments. This subroutine enables the ABAQUSmore » finite element code to be used for analyzing the thermo-mechanical behavior of samples and parts that are made from glassy polymers.« less
xiSPEC: web-based visualization, analysis and sharing of proteomics data.
Kolbowski, Lars; Combe, Colin; Rappsilber, Juri
2018-05-08
We present xiSPEC, a standard compliant, next-generation web-based spectrum viewer for visualizing, analyzing and sharing mass spectrometry data. Peptide-spectrum matches from standard proteomics and cross-linking experiments are supported. xiSPEC is to date the only browser-based tool supporting the standardized file formats mzML and mzIdentML defined by the proteomics standards initiative. Users can either upload data directly or select files from the PRIDE data repository as input. xiSPEC allows users to save and share their datasets publicly or password protected for providing access to collaborators or readers and reviewers of manuscripts. The identification table features advanced interaction controls and spectra are presented in three interconnected views: (i) annotated mass spectrum, (ii) peptide sequence fragmentation key and (iii) quality control error plots of matched fragments. Highlighting or selecting data points in any view is represented in all other views. Views are interactive scalable vector graphic elements, which can be exported, e.g. for use in publication. xiSPEC allows for re-annotation of spectra for easy hypothesis testing by modifying input data. xiSPEC is freely accessible at http://spectrumviewer.org and the source code is openly available on https://github.com/Rappsilber-Laboratory/xiSPEC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malin, Martha J.; Bartol, Laura J.; DeWerd, Larry A., E-mail: mmalin@wisc.edu, E-mail: ladewerd@wisc.edu
2015-05-15
Purpose: To investigate why dose-rate constants for {sup 125}I and {sup 103}Pd seeds computed using the spectroscopic technique, Λ{sub spec}, differ from those computed with standard Monte Carlo (MC) techniques. A potential cause of these discrepancies is the spectroscopic technique’s use of approximations of the true fluence distribution leaving the source, φ{sub full}. In particular, the fluence distribution used in the spectroscopic technique, φ{sub spec}, approximates the spatial, angular, and energy distributions of φ{sub full}. This work quantified the extent to which each of these approximations affects the accuracy of Λ{sub spec}. Additionally, this study investigated how the simplified water-onlymore » model used in the spectroscopic technique impacts the accuracy of Λ{sub spec}. Methods: Dose-rate constants as described in the AAPM TG-43U1 report, Λ{sub full}, were computed with MC simulations using the full source geometry for each of 14 different {sup 125}I and 6 different {sup 103}Pd source models. In addition, the spectrum emitted along the perpendicular bisector of each source was simulated in vacuum using the full source model and used to compute Λ{sub spec}. Λ{sub spec} was compared to Λ{sub full} to verify the discrepancy reported by Rodriguez and Rogers. Using MC simulations, a phase space of the fluence leaving the encapsulation of each full source model was created. The spatial and angular distributions of φ{sub full} were extracted from the phase spaces and were qualitatively compared to those used by φ{sub spec}. Additionally, each phase space was modified to reflect one of the approximated distributions (spatial, angular, or energy) used by φ{sub spec}. The dose-rate constant resulting from using approximated distribution i, Λ{sub approx,i}, was computed using the modified phase space and compared to Λ{sub full}. For each source, this process was repeated for each approximation in order to determine which approximations used in the spectroscopic technique affect the accuracy of Λ{sub spec}. Results: For all sources studied, the angular and spatial distributions of φ{sub full} were more complex than the distributions used in φ{sub spec}. Differences between Λ{sub spec} and Λ{sub full} ranged from −0.6% to +6.4%, confirming the discrepancies found by Rodriguez and Rogers. The largest contribution to the discrepancy was the assumption of isotropic emission in φ{sub spec}, which caused differences in Λ of up to +5.3% relative to Λ{sub full}. Use of the approximated spatial and energy distributions caused smaller average discrepancies in Λ of −0.4% and +0.1%, respectively. The water-only model introduced an average discrepancy in Λ of −0.4%. Conclusions: The approximations used in φ{sub spec} caused discrepancies between Λ{sub approx,i} and Λ{sub full} of up to 7.8%. With the exception of the energy distribution, the approximations used in φ{sub spec} contributed to this discrepancy for all source models studied. To improve the accuracy of Λ{sub spec}, the spatial and angular distributions of φ{sub full} could be measured, with the measurements replacing the approximated distributions. The methodology used in this work could be used to determine the resolution that such measurements would require by computing the dose-rate constants from phase spaces modified to reflect φ{sub full} binned at different spatial and angular resolutions.« less
NASA Astrophysics Data System (ADS)
Bylyku, Elida
2009-04-01
In Albania in recent years it has been of increasing interest to determine various pollutants in the environment and their possible effects on human health. The radiochemical procedure used to identify Pu, Am, U, Th, and Sr radioisotopes in soil, sediment, water, coal, and milk samples is described. The analysis is carried out in the presence of respective tracer solutions and combines the procedure for Pu analysis based on anion exchange, the selective method for Sr isolation based on extraction chromatography using Sr-Spec resin, and the application of the TRU-Spec column for separation of Am fraction. An acid digestion method has been applied for the decomposition of samples. The radiochemical procedure involves the separation of Pu from Th, Am, and Sr by anion exchange, followed by the preconcentration of Am and Sr by coprecipitation with calcium oxalate. Am is separated from Sr by extraction chromatography. Uranium is separated from the bulk elements by liquid-liquid extraction using UTEVA® resin. Thin sources for alpha spectrometric measurements are prepared by microprecipitation with NdF3. Two International Atomic Energy Agency reference materials were analyzed in parallel with the samples.
Cho, Jin-Young; Lee, Hyoung-Joo; Jeong, Seul-Ki; Paik, Young-Ki
2017-12-01
Mass spectrometry (MS) is a widely used proteome analysis tool for biomedical science. In an MS-based bottom-up proteomic approach to protein identification, sequence database (DB) searching has been routinely used because of its simplicity and convenience. However, searching a sequence DB with multiple variable modification options can increase processing time, false-positive errors in large and complicated MS data sets. Spectral library searching is an alternative solution, avoiding the limitations of sequence DB searching and allowing the detection of more peptides with high sensitivity. Unfortunately, this technique has less proteome coverage, resulting in limitations in the detection of novel and whole peptide sequences in biological samples. To solve these problems, we previously developed the "Combo-Spec Search" method, which uses manually multiple references and simulated spectral library searching to analyze whole proteomes in a biological sample. In this study, we have developed a new analytical interface tool called "Epsilon-Q" to enhance the functions of both the Combo-Spec Search method and label-free protein quantification. Epsilon-Q performs automatically multiple spectral library searching, class-specific false-discovery rate control, and result integration. It has a user-friendly graphical interface and demonstrates good performance in identifying and quantifying proteins by supporting standard MS data formats and spectrum-to-spectrum matching powered by SpectraST. Furthermore, when the Epsilon-Q interface is combined with the Combo-Spec search method, called the Epsilon-Q system, it shows a synergistic function by outperforming other sequence DB search engines for identifying and quantifying low-abundance proteins in biological samples. The Epsilon-Q system can be a versatile tool for comparative proteome analysis based on multiple spectral libraries and label-free quantification.
Gallium Arsenide Pilot Line for High Performance Components
1988-06-02
shown in Figure 4. A complete functional and timing verification was performed by GOALIE , MOTIS, and ADVICE tools. GOALIE was used to convert the...using LTX2 and was verified using GOALIE , and ADVICE. S The performance of the circuits was measured using 256 test-vectors on an Advantest T3340...cycling per MIL STD 883C, Method 1010.7 Condition C. No evidence of damage was found. A sample of fifteen leads were pull tested per MIL STD 883C. Method
2013-12-01
points in the waveform. This is useful if the digitization rate is unnecessarily high and the waveform content remains unchanged at lower sampling...there is a precursor acoustic event not included in the waveform, like another impulse or high background noise. MIL-STD-1474E defines an exposure as...Breaking strain of annular ligament filaments Ramp 6 unitless ratio Ratio of resistance to stiffness of annular ligament at high loads So 1.00E+09
Feldspathic Meteorites MIL 090034 and 090070: Late Additions to the Lunar Crust
NASA Technical Reports Server (NTRS)
Nyquist, L. E.; Shirai, N.; Yamaguchi, A.; Shih, C.-Y.; Park, J.; Ebihara, M.
2016-01-01
Our studies of the Miller Range lunar meteorites MIL 090034, 090036, and 090070 show them to be a diverse suite of rocks from the lunar highlands hereafter referred to as MIL 34, MIL 36, and MIL 70, resp. MIL34 and MIL70, the focus of this work, are crystalline melt breccias. Plagioclase compositions in both peak sharply around An96-97. Mg numbers of olivine vary from 58-65 with a few higher values. MIL36 is a regolith breccia. MIL 34 and MIL 70 have some of the highest Al2O3 abundances of lunar highland meteorites, indicating that they have among the largest modal abundances of plagioclase for lunar meteorites. They have lower Sc and Cr abundances than nearly all lunar highland meteorites except Dho 081, Dho 489 and Dho 733. MIL34 and MIL70 also have similar cosmic ray exposure (CRE) ages of approximately 1-2 Ma indicating they are launch paired. (MIL36 has a larger CRE age approximately greater than 70 Ma). Park et al. found a variation in Ar-Ar ages among subsamples of MIL 34 and MIL70, but preferred ages of 3500+/-110 Ma for the "Dark" phase of MIL 34 anorthite and 3520+/-30 Ma for the "Light" phase of MIL70. Bouvier et al. reported a Pb-Pb age of 3894+/-39 Ma for a feldspathic clast of MIL 34 and a similar age for a melt lithology. Here we reexamine the Rb-Sr and Sm-Nd isotopic data, which show complexities qualitatively consistent with those of the Ar-Ar and Pb-Pb data. The Sm-Nd data in particular suggest that the feldspathic compositions of MIL 34 and MIL 70 formed during initial lunar geochemical differentiation, and REE modeling suggests a relatively late-stage formation.
Qian Tang, Xue; Dan Zhang, Yi; Wei Jiang, Zhong; Mei Wang, Dong; Zhi Huang, Cheng; Fang Li, Yuan
2018-03-01
In this work, Fe 3 O 4 and metal-organic framework MIL-101(Fe) composites (Fe 3 O 4 /MIL-101(Fe)) was demonstrated to possess excellent catalytic property to directly catalyze luminol chemiluminescence without extra oxidants. We utilized Fe 3 O 4 /MIL-101(Fe) to develop a ultra-sensitive quantitative analytical method for H 2 O 2 and glucose. The possible mechanism of the chemiluminescence reaction had been investigated. Under optimal conditions, the relative chemiluminescence intensity was linearly proportional to the logarithm of H 2 O 2 concentration in the range of 5-150nM with a limit of detection of 3.7nM (signal-to-noise ratio = 3), and glucose could be linearly detected in the range from 5 to 100nM and the detection limit was 4.9nM (signal-to-noise ratio = 3). Furthermore, the present approach was successfully applied to quantitative determination of H 2 O 2 in medical disinfectant and glucose in human serum samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Hunt, Charles D.
2015-01-01
Some fraction of septic leachate is expected in groundwater because there are unsewered suburban and commercial developments upslope from the Park that rely on cesspools and septic systems. However, stable isotopes of nitrate did not implicate septic-waste nitrogen (heavy δ15N values on the order of +10 per mil or greater). Instead, the heaviest δ15N values of +6 to +8 per mil were associated with the large fishponds, likely as a result of biotic cycling. Water samples with δ15N values of +3 to +5 per mil were still isotopically heavier than the upland groundwater value of +2 per mil and likely reflect addition of heavier nitrogen, possibly from septic sources, nitrogen-fixing vegetation, or vehicular exhaust. Pharmaceuticals, wastewater compounds, and volatile organic compounds indicated that if contamination is present, it appears to be at low, barely detectable, levels--at least as reflected by the results of this study. The most diagnostic indication of septic contamination was at monitoring well KAHO 2, closest to Kaloko Light Industrial Park, where three pharmaceuticals (carbamazepine, sulfamethoxazole, and thiobendazole) were detected at trace-level parts-per-trillion concentrations. A screening-level test for laundry fabric brighteners indicated positive detection at most sites; however, readings were quite low and if laundry graywater is present, it appears to be a small, dilute fraction. Because the weather was persistently dry throughout the study period, the USGS team was unable to conduct a wet-weather “storm” sampling. Wet-weather results are expected to differ from those reported here, though by how much remains unknown.
NASA Astrophysics Data System (ADS)
Burton, A. S.; Berger, E. L.; Locke, D. R.; Lewis, E. K.; Moore, J. F.
2018-04-01
Laser microprobe of surfaces utilizing a two laser setup whereby the desorption laser threshold is lowered below ionization, and the resulting neutral plume is examined using 157nm Vacuum Ultraviolet laser light for mass spec surface mapping.
Use of Management Statistics in ARL Libraries. SPEC Kit #153.
ERIC Educational Resources Information Center
Vasi, John
A Systems and Procedures Exchange Center (SPEC) survey conducted in 1986 investigated the collection and use of management statistics in Association of Research Libraries (ARL) member libraries, and SPEC Kit #134 (May 1987) summarized the kinds of statistics collected and the reasons given by the 91 respondents for collecting them. This more…
SPECS: The Kilometer-baseline Far-IR Interferometer in NASA's Space Science Roadmap Presentation
NASA Technical Reports Server (NTRS)
Abel, Tom; Allen, Ron; Benford, Dominic; Blain, Andrew; Bombardelli, Claudio; Calzetti, Daniela; DiPirro, Michael J.; Ehrenfreund, Pascale; Evans, Neal; Fischer, Jackie
2004-01-01
A viewgraph presentation describing the Submillimeter Probe of the Evolution of Cosmic Structure (SPECS) mission is shown. The topics include: 1) Context: community planning and study status; 2) Science goals; 3) Mission requirements; 4) Mission concepts for SPIRIT and SPECS; and 5) Tethered formation flying, a key enabling technology.
Management of Library Security. SPEC Kit 247 and SPEC Flyer 247.
ERIC Educational Resources Information Center
Soete, George J., Comp.; Zimmerman, Glen, Comp.
This SPEC (Systems and Procedures Exchange Center) Kit and Flyer reports results of a survey conducted in January 1999 that examined how ARL (Association of Research Libraries) member libraries assure the safety and security of persons, library materials, physical facilities, furnishings, computer equipment, etc. Forty-five of the 122 ARL member…
NASA Astrophysics Data System (ADS)
Matsuda, S.; Kasahara, Y.; Kojima, H.; Kasaba, Y.; Yagitani, S.; Ozaki, M.; Imachi, T.; Ishisaka, K.; Kurita, S.; Ota, M.; Kumamoto, A.; Tsuchiya, F.; Yoshizumi, M.; Matsuoka, A.; Teramoto, M.; Shinohara, I.
2017-12-01
Exploration of energization and Radiation in Geospace (ERG) is a mission for understanding particle acceleration, loss mechanisms, and the dynamic evolution of space storms in the context of cross-energy and cross-regional coupling [Miyoshi et al., 2012]. The ERG (ARASE) satellite was launched on December 20, 2016, and successfully inserted into an orbit. The Plasma Wave Experiment (PWE) is one of the science instruments on board the ERG satellite to measure electric field and magnetic field in the inner magnetosphere. PWE consists of three sub-components, EFD (Electric Field Detector), OFA/WFC (Onboard Frequency Analyzer and Waveform Capture), and HFA (High Frequency Analyzer). Especially, OFA/WFC measures electric and magnetic field spectrum and waveform from a few Hz to 20 kHz. OFA/WFC processes signals detected by a couple of dipole wire-probe antenna (WPT) and tri-axis magnetic search coils (MSC) installed onboard the satellite. The PWE-OFA subsystem calculates and produces three kind of data; OFA-SPEC (power spectrum), OFA-MATRIX (spectrum matrix), and OFA-COMPLEX (complex spectrum). They are continuously processed 24 hours per day and all data are sent to the ground. OFA-MATRIX and OFA-COMPLEX are used for polarization analyses and direction finding of the plasma waves. The PWE-WFC subsystem measures raw (64 kHz sampled) and down-sampled (1 kHz sampled) burst waveform detected by the WPT and the MSC sensors. It activates by a command, automatic triggering, and scheduling. The initial check-out process of the PWE successfully completed, and initial data has been obtained. In this presentation, we introduce onboard processing technique on PWE OFA/WFC and its initial results.
An, Jiwoo; Rahn, Kira L; Anderson, Jared L
2017-05-15
A headspace single drop microextraction (HS-SDME) method and a dispersive liquid-liquid microextraction (DLLME) method were developed using two tetrachloromanganate ([MnCl 4 2- ])-based magnetic ionic liquids (MIL) as extraction solvents for the determination of twelve aromatic compounds, including four polyaromatic hydrocarbons, by reversed phase high-performance liquid chromatography (HPLC). The analytical performance of the developed HS-SDME method was compared to the DLLME approach employing the same MILs. In the HS-SDME approach, the magnetic field generated by the magnet was exploited to suspend the MIL solvent from the tip of a rod magnet. The utilization of MILs in HS-SDME resulted in a highly stable microdroplet under elevated temperatures and long extraction times, overcoming a common challenge encountered in traditional SDME approaches of droplet instability. The low UV absorbance of the [MnCl 4 2- ]-based MILs permitted direct analysis of the analyte enriched extraction solvent by HPLC. In HS-SDME, the effects of ionic strength of the sample solution, temperature of the extraction system, extraction time, stir rate, and headspace volume on extraction efficiencies were examined. Coefficients of determination (R 2 ) ranged from 0.994 to 0.999 and limits of detection (LODs) varied from 0.04 to 1.0μgL -1 with relative recoveries from lake water ranging from 70.2% to 109.6%. For the DLLME method, parameters including disperser solvent type and volume, ionic strength of the sample solution, mass of extraction solvent, and extraction time were studied and optimized. Coefficients of determination for the DLLME method varied from 0.997 to 0.999 with LODs ranging from 0.05 to 1.0μgL -1 . Relative recoveries from lake water samples ranged from 68.7% to 104.5%. Overall, the DLLME approach permitted faster extraction times and higher enrichment factors for analytes with low vapor pressure whereas the HS-SDME approach exhibited better extraction efficiencies for analytes with relatively higher vapor pressure. Copyright © 2017 Elsevier B.V. All rights reserved.
Lu, Nan; Wang, Ting; Zhao, Pan; Zhang, Lianjun; Lun, Xiaowen; Zhang, Xueli; Hou, Xiaohong
2016-11-01
In the presented work, metal-organic framework (MOF) material MIL-101(Cr) (MIL, Matérial Institute Lavoisier) was used as a sorbent for vortex assisted dispersive micro-solid-phase extraction (VA-D-μ-SPE) of trace amount of metronidazole (MNZ), ronidazole (RNZ), secnidazole (SNZ), dimetridazole (DMZ), tinidazole (TNZ), and ornidazole (ONZ) in different environmental water samples. Ultra-high-performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) was used to quantify the target analytes. The extraction conditions, including type of sorbents, amount of MIL-101(Cr), solution pH, extraction method, extraction time, effect of salt, and elution conditions were investigated. Upon the optimal conditions, the developed method showed an excellent extraction performance with the average recovery ranging from 75.2 to 98.8 %. Good sensitivity levels were achieved with the detection limits of 0.03∼0.06 μg/L and the quantitation limits of 0.09∼0.20 μg/L. The linear ranges were varied from 0.1 to 20 for SNZ and ONZ and from 0.2 to 40 μg/L for MNZ, RNZ, DMZ, and TNZ (r 2 > 0.992), and repeatability of the method was satisfactory with the relative standard deviations (RSD) <8 %. Ultimately, the applicability of the method was successfully confirmed by the extraction and determination of 5-nitroimidazoles (5-NDZs) in 12 real water samples, showing the positive findings of MNZ and TNZ ranging from 0.3 to 1.0 μg/L. Furthermore, molecular docking was applied to explain the molecular interactions and free binding energies between MIL-101(Cr) and 5-NDZs, providing a deep insight into the adsorption mechanism. The proposed method exhibited the advantages of simplicity, rapidly, less solvent consumption, ease of operation, higher sensitivity, and lower matrix effect. Graphical abstract Schematic diagram of the extraction process and molecular docking investigation.
NASA Astrophysics Data System (ADS)
Larson, P. B.; Nichols, H. J.; Wolff, J. A.; Marti, J.
2001-12-01
As part of an ongoing project investigating assimilation in ocean island magmas, we are measuring stable isotope ratios of hydrothermally altered lithic fragments in phonolitic pyroclastic deposits from Tenerife, Canary Islands. Nepheline syenite blocks occur in the 0.196 Ma El Abrigo ignimbrite of the Diego Hernandez Formation (DHF). The DHF is the most recent of at least three caldera-forming magmatic cycles on Tenerife. The blocks are fragments of evolved plutons that are chemically similar to phonolites but extend to more strongly differentiated compositions. Distinct major and trace element concentrations suggest that the blocks derive from two intrusions, here referred to as A and B. The B syenites have chemical affinities with the El Abrigo phonolite, and some blocks contain small pockets of residual glass, suggesting that the B pluton may have been coeval with the El Abrigo magma. O isotope ratios of the B syenites lie within the range 4.8 to 7.0 per mil. The B samples are mostly fresh, and their higher O isotope ratios are near pristine magmatic values. Lower values occur in rocks with mild hydrothermal mineralogic alteration, and their values reflect limited high-temperature water-rock isotope exchange. O isotope ratios for A blocks are lower (0.1 to 6.3 per mil, most less than 2.0 per mil), and some samples show extensive mineral alteration. Near-ubiquitous alteration among the A samples, distinct major and trace element compositions, and lack of glass show that this syenite was older than, and unrelated to, the El Abrigo magma. Syenite D/H ratios range from -90 to -120 per mil. O vs H isotope relations indicate that an 18O-depleted meteoric water was the most important reservoir for the high-temperature hydrothermal fluid. Assimilation of altered syenite should provide a distinct stable isotope fingerprint that would be inherited by the product magma. DHF phonolites yield O ratios in the range 5.5 to 7.0 per mil, which may be this fingerprint. Assimilation of variably altered syenites, with accompanying fractionation, is a viable mechanism for producing this stable isotope variability in the magmas.
Sousa, R; Serrano, P; Gomes Dias, J; Oliveira, J C; Oliveira, A
2017-03-01
The aims of this study were to increase the diagnostic accuracy of the analysis of synovial fluid in the differentiation of prosthetic joint infection (PJI) by the addition of inexpensive biomarkers such as the levels of C-reactive protein (CRP), adenosine deaminase (ADA), alpha-2-macrogloblulin (α2M) and procalcitonin. Between January 2013 and December 2015, synovial fluid and removed implants were requested from 143 revision total joint arthroplasties. A total of 55 patients met inclusion criteria of the receipt of sufficient synovial fluid, tissue samples and removed implants for analysis. The diagnosis of PJI followed the definition from a recent International Consensus Meeting to create two groups of patients; septic and aseptic. Using receiver operating characteristic curves we determined the cutoff values and diagnostic accuracy for each marker. There were 23 PJIs and 32 patients with aseptic loosening. The levels of total leucocyte count, proportion of polymorphonuclear leucocytes (PMNs), CRP, ADA and α2M in the synovial fluid were all significantly higher in those with a PJI than in those with aseptic loosening. The levels of procalcitonin were comparable in the two groups. Cutoff values for the optimal performance in the diagnosis of infection were: total leucocyte count > 1463 cells/μL (sensitivity (Sens) 100%, specificity (Spec) 71.9%, positive predictive value (PPV) 71.9%, negative predictive value (NPV) 100%); proportion of PMNs > 81% (Sens 78.3%, Spec 75.0%, PPV 69.2%, NPV 82.8%); CRP > 6.7mg/L (Sens 78.3%, Spec 93.8%, PPV 90.0%, NPV 85.7%); ADA > 61U/L (Sens 78.3%, Spec 96.9%, PPV 94.7%, NPV 86.1%) and α2M > 958 mg/L (Sens 47.8%, Spec 96.9%, PPV 91.7%, NPV 72.1%). The addition of a raised level of CRP or ADA to the total leukocyte count increased the specificity: total leukocyte count > 1463 cells/μL and CRP > 6.7mg/L (Sens 78.3%, Spec 100%, PPV 100%, NPV 86.5%) or with ADA > 61U/L (Sens 78.3%, Spec 96.9%, PPV 94.7%, NPV 86.1%). The total leucocyte count in the synovial fluid offers great negative predictive value in the diagnosis of PJI and the addition of more specific markers such as CRP and ADA improves the positive predictive value. Thus the addition of simple and inexpensive markers to the measurement of the leucocyte count in the synovial fluid may reduce the number of equivocal results which demand more expensive investigation. Cite this article: Bone Joint J 2017;99-B:351-7. ©2017 The British Editorial Society of Bone & Joint Surgery.
Benedé, Juan L; Anderson, Jared L; Chisvert, Alberto
2018-01-01
In this work, a novel hybrid approach called stir bar dispersive liquid microextraction (SBDLME) that combines the advantages of stir bar sorptive extraction (SBSE) and dispersive liquid-liquid microextraction (DLLME) has been employed for the accurate and sensitive determination of ten polycyclic aromatic hydrocarbons (PAHs) in natural water samples. The extraction is carried out using a neodymium stir bar magnetically coated with a magnetic ionic liquid (MIL) as extraction device, in such a way that the MIL is dispersed into the solution at high stirring rates. Once the stirring is ceased, the MIL is magnetically retrieved onto the stir bar, and subsequently subjected to thermal desorption (TD) coupled to a gas chromatography-mass spectrometry (GC-MS) system. The main parameters involved in TD, as well as in the extraction step affecting the extraction efficiency (i.e., MIL amount, extraction time and ionic strength) were evaluated. Under the optimized conditions, the method was successfully validated showing good linearity, limits of detection and quantification in the low ng L -1 level, good intra- and inter-day repeatability (RSD < 13%) and good enrichment factors (18 - 717). This sensitive analytical method was applied to the determination of trace amounts of PAHs in three natural water samples (river, tap and rainwater) with satisfactory relative recovery values (84-115%), highlighting that the matrices under consideration do not affect the extraction process. Copyright © 2017 Elsevier B.V. All rights reserved.
Furniture Rack Corrosion Coupon Surveillance - 2012 Update
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mickalonis, J. I.; Murphy, T. R.; Berry, C. J.
Under the L Basin corrosion surveillance program furniture rack coupons immersed for 14 years (FY2009 coupons) and 16 years (FY2011 coupons) were analyzed and the results trended with coupons exposed for shorter times. In addition, a section harvested from an actual furniture rack that was immersed for 14 years was analyzed for pitting in the weld and heat-affected-zone (HAZ) regions. The L Basin operations maintained very good water quality over the entire immersion period for these samples. These results for FY2009 and FY2011 coupons showed that the average pit depths for the 6061 and 6063 base metal are 1 andmore » 2 mils, respectively, while those for the weld and HAZ are 3 and 4 mils, respectively. The results for the weld and HAZ regions are similar to coupons removed during the period of FY2003 to FY2007. These similarities indicate that the pit development occurred quickly followed by slow kinetics of increase in pit depth. For the actual furniture rack sample average pits of 5 and 2 mils were measured for the HAZ and weld, respectively. These results demonstrate that pitting corrosion of the aluminum furniture racks used to support the spent fuel occurs in waters of good quality. The corrosion kinetics or pit depth growth rate is much less that 1 mil/year, and would not impact long-term use of this material system for fuel storage racks in L Basin if good water quality is maintained.« less
NASA Astrophysics Data System (ADS)
Abdpour, Soheil; Kowsari, Elaheh; Moghaddam, Mohammad Reza Alavi
2018-06-01
The MIL-100(Fe)@MIL-53(Fe) was synthesized by the ultrasound method, while the initial solution for the preparation of the photocatalysts was included nanoparticles of MIL-100(Fe) and a precursor solution for the synthesizing of MIL-53(Fe). After an appropriate time of reaction, nanoparticles of MIL-100(Fe) were decorated on the surface of MIL-53(Fe). Phtoelectrochemical/electrochemical and photocatalytic degradation of methyl orange over MIL-100(Fe)@MIL-53(Fe) were explored. The phtoelectrochemical/electrochemical and photocatalytic performance of the prepared photocatalysts revealed that the introduction of nanoparticles of the MIL-100(Fe) on the surface of MIL-53(Fe) enhanced the photocatalytic performance of the resulted photocatalyst compared to pure MIL-53(Fe) and MIL-100(Fe). The enhanced photocatalytic efficiency is ascribed to increase the visible light region absorption and to decrease the electron-hole recombination rate in the hybrid photocatalyst. The present work demonstrated that the photocatalytic properties of metal organic frameworks (MOFs) can be improved by the fabrication of hybrid photocatalysts based on the different types of MOFs.
United States Air Force Analysis Extract AFSC 2A6X4 Aircraft Fuel Systems (ANG/AFRC)
2001-02-01
8217AFOMS (AETC) Randolph AFB TX’ V0226 Spec tools/equip use/oper - Rollers or Stitchers ...8217 V0226 Spec tools/equip use/oper - Rollers or Stitchers ANG ANG ANG RES RES...8217AFOMS (AETC) Randolph AFB TX’ V0226 Spec tools/equip use/oper - Rollers or Stitchers
Building Use Policies. SPEC Kit 144.
ERIC Educational Resources Information Center
Coyle, Patrick
This Systems and Procedures Exchange Center (SPEC) flyer/kit addresses some of the needs of Association of Research Libraries (ARL) members regarding library building use and the aesthetics and well-being of the materials and people in the building. The kit draws upon documents gathered as part of a 1986 Quick-SPEC survey that dealt with food and…
Web Page Development and Management. SPEC Kit 246 and SPEC Flyer 246.
ERIC Educational Resources Information Center
Liu, Yaping Peter, Comp.
This SPEC (Systems and Procedures Exchange Center) Kit and Flyer reports results of two surveys conducted in 1996 and 1998 that examined ARL (Association of Research Libraries) member libraries' World Wide Web history, development, use, and activities. Fifty-six out of the then 119 ARL member institutions responded to the 1996 survey, and 68 out…
Computerized Online Bibliographic Searching. SPEC Kit #154.
ERIC Educational Resources Information Center
Hocker, Susan
For this kit, 106 Association of Research Libraries (ARL) academic libraries were surveyed concerning: (1) current administration/organization; (2) evaluation; (3) patron relations; (4) services; and (5) the impact of online searching on collections. Responses were received from 83 libraries, many of which contributed sample materials. Analyses of…
Hydrogen Isotope Geochemistry of Mariana Trough Lavas
NASA Astrophysics Data System (ADS)
Oleary, J.; Kitchen, N.; Eiler, J.
2002-12-01
Basaltic lavas from the Marianas trough vary in water content from values similar to mid-ocean ridge basalts (MORBs) to ten times those values. These variations plausibly reflect addition of subducted water to the mantle wedge, but must also reflect variations in extent of melting and crystallization-differentiation. We report hydrogen isotope data for 18 samples of lavas from the Mariana trough; these measurements, when combined with other geochemical data, constrain the relative proportions of subducted vs. 'primitive' water in their mantle sources. Previous measurements of the hydrogen isotope composition of Mariana trough lavas [1] found a correlation between dD and measured water content, consistent with two-component mixing between water in the ambient MORB source and water from the subducted slab, but include only four samples, only two of which have known major and minor element geochemistry. Our purpose is to confirm this result and expand it to include a more representative sampling. Our measurements made use of a recently developed technique for on-line stepped heating, water reduction and hydrogen isotope mass spectrometry [2]. This method is appropriate for relatively small samples of basaltic glass (ca. 100 μg to 1 mg) and up to 10 analyses can be performed per day. Its principle advantages for our purposes are that it can be applied to even small or glass-poor samples and it is fast enough to permit replication of all data and analysis of relatively large numbers of standards. Hydrogen isotope compositions of Mariana trough lavas vary between -74 per mil and -34 per mil (SMOW); this compares with a range of -46 to -32 per mil for related lavas in [1] and is similar to the previously observed range for back-arc-basin basalts generally (-70 to -32 per mil). Two-thirds of our sample suite span a small range in dD (-40+/-4 ). We suggest this average is the most representative value for back arc basin basalts measured to-date. Our data are inconsistent with the correlation between dD and measured water content suggested for back-arc basin basalts by [ref], even considering only lavas spanning a small range in MgO. This suggests one or both of two things: (1) melting and/or crystallization differentiation produce variations in water abundance unrelated to the abundance and dD of water in the mantle source; (2) there are three or more reservoirs in the mantle wedge of the Mariana arc, all of which differ in dD and water content (i.e., such that data do not define a simple line in a plot of dD vs. 1/H2O). The first of these is significant, but there is also evidence for the second. In particular, dD values decrease monotonically with increasing abundance of highly incompatible trace elements and with increasing La/Sm and K2O/H2O ratios; the lowest dD sample in our suite is an enriched basalt (La/Sm = 3.6) with an 'arc like' K2O content (0.71 wt. %). These data suggest that water in the mantle wedge of the Mariana arc is derived from three sources: ambient water common to the MORB source (ca. 0.02 wt. % H2O; dD ~ -65 to -75 per mil), subducted water (dD ~ -30 per mil) and an enriched source having high abundances of water and other incompatible trace elements and a dD value of ca. -80 per mil. [1] Poreda, 1985, EPSL 73, 244-254 [2] Eiler and Kitchen, 2001, GCA 65, 24, 4467-4479
Defining defect specifications to optimize photomask production and requalification
NASA Astrophysics Data System (ADS)
Fiekowsky, Peter
2006-10-01
Reducing defect repairs and accelerating defect analysis is becoming more important as the total cost of defect repairs on advanced masks increases. Photomask defect specs based on printability, as measured on AIMS microscopes has been used for years, but the fundamental defect spec is still the defect size, as measured on the photomask, requiring the repair of many unprintable defects. ADAS, the Automated Defect Analysis System from AVI is now available in most advanced mask shops. It makes the use of pure printability specs, or "Optimal Defect Specs" practical. This software uses advanced algorithms to eliminate false defects caused by approximations in the inspection algorithm, classify each defect, simulate each defect and disposition each defect based on its printability and location. This paper defines "optimal defect specs", explains why they are now practical and economic, gives a method of determining them and provides accuracy data.
Wang, Ting; Wang, Jian; Zhang, Conglu; Yang, Zhao; Dai, Xinpeng; Cheng, Maosheng; Hou, Xiaohong
2015-08-07
An attractive metal-organic framework (MOF) MIL-101(Cr) material was synthesized at the nanoscale and applied as a sorbent in the porous membrane-protected micro-solid-phase extraction (μ-SPE) device for the pre-concentration of phthalate esters (PAEs) in drinking water samples for the first time. Parameters influencing the extraction efficiency, such as the selection of sorbent materials, pH adjustment, the effect of salt, magnetic-stirring extraction time, the desorption solvent and the desorption time, were investigated. Under the optimum conditions, the limits of detection from gas chromatography-mass spectrometric analysis for PAEs varied from 0.004 to 0.02 μg L(-1). The linear ranges were from 0.1 to 50 μg L(-1) or from 0.2 to 50 μg L(-1) for the analytes with the relative standard deviations fluctuating from 0.8 to 10.9% (n = 5). The enrichment factors (EFs) for the target PAEs were varied from 143 to 187. MIL-101(Cr) exhibited remarkable advantages compared to activated carbon and MIL-100(Fe). On the other hand, the computational method was first used to predict the adsorption of MIL-101(Cr) towards PAEs. The molecular interactions and the free binding energies between MIL-101(Cr) and PAEs were observed and calculated in terms of the molecular modeling method. MIL-101(Cr) showed high potential in the analysis of PAEs at trace levels in drinking water. The computational result was consistent with the detected enrichment factors. The computational modeling accurately predicted the extraction efficiency of MOF-based material towards the target analytes. Therefore, the combination of experimental and computational study provided a new strategy on the trace contaminant analysis.
Application of Ultrasonic Guided Waves for Evaluating Aging Wire Insulation
NASA Technical Reports Server (NTRS)
Anastasi, Robert F.; Madaras, Eric I.
2005-01-01
Aging wiring has become a critical issue to the aerospace and aircraft industries due to Shuttle and aircraft incidents. The problem is that over time the insulation on wire becomes brittle and cracks. This exposes the underlying conductive wire to the potential for short circuits and fire. Popular methods of monitoring aging wire problems focuses on applying electrical sensing techniques that are sensitive to the conductor's condition, but not very sensitive to the wire insulation's condition. Measurement of wire insulation stiffness and ultrasonic properties by ultrasonic guided waves is being examined. Experimental measurements showed that the lowest order extensional mode could be sensitive to stiffness changes in the wire insulation. To test this theory conventional wire samples were heat damaged in an oven, in a range of heating conditions. The samples were 12, 16, and 20 gauge and the heat damage introduced material changes in the wire insulation that made the originally flexible insulation brittle and darker in color. Results showed that extensional mode phase velocity increased for the samples that were exposed to heat for longer duration.
Interface for the rapid analysis of liquid samples by accelerator mass spectrometry
Turteltaub, Kenneth; Ognibene, Ted; Thomas, Avi; Daley, Paul F; Salazar Quintero, Gary A; Bench, Graham
2014-02-04
An interface for the analysis of liquid sample having carbon content by an accelerator mass spectrometer including a wire, defects on the wire, a system for moving the wire, a droplet maker for producing droplets of the liquid sample and placing the droplets of the liquid sample on the wire in the defects, a system that converts the carbon content of the droplets of the liquid sample to carbon dioxide gas in a helium stream, and a gas-accepting ion source connected to the accelerator mass spectrometer that receives the carbon dioxide gas of the sample in a helium stream and introduces the carbon dioxide gas of the sample into the accelerator mass spectrometer.
Katanik, M. T.; Schneider, S. K.; Rosenblatt, J. E.; Hall, G. S.; Procop, G. W.
2001-01-01
Detection of Giardia and Cryptosporidium in clinical stool specimens using the ColorPAC and ProSpecT enzyme immunoassays revealed 98.7% agreement for Giardia detection and 98.1% agreement for Cryptosporidium detection. Sensitivities were uniformly 100%. The specificities of the ColorPAC immunoassay for Giardia and Cryptosporidium detection were 100 and 99.5%, respectively, and those for the ProSpecT assay were 98.4 and 98.6%, respectively. The false-positive reactions with the ProSpecT assay occurred with specimens that were grossly bloody. PMID:11724874
49 CFR 571.5 - Matter incorporated by reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
.../. (1) MIL-S-13192, “Military Specification, Shoes, Men's, Dress, Oxford,” October 30, 1976, into § 571.214. (2) MIL-S-13192P, “Military Specification, Shoes, Men's, Dress, Oxford,” 1988, including Amendment 1, October 14, 1994, into § 571.208. (3) MIL-S-21711E, “Military Specification, Shoes, Women's,” 3...
49 CFR 571.5 - Matter incorporated by reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
.../. (1) MIL-S-13192, “Military Specification, Shoes, Men's, Dress, Oxford,” October 30, 1976, into § 571.214. (2) MIL-S-13192P, “Military Specification, Shoes, Men's, Dress, Oxford,” 1988, including Amendment 1, October 14, 1994, into § 571.208. (3) MIL-S-21711E, “Military Specification, Shoes, Women's,” 3...
49 CFR 571.5 - Matter incorporated by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
.../. (1) MIL-S-13192, “Military Specification, Shoes, Men's, Dress, Oxford,” October 30, 1976, into § 571.214. (2) MIL-S-13192P, “Military Specification, Shoes, Men's, Dress, Oxford,” 1988, including Amendment 1, October 14, 1994, into § 571.208. (3) MIL-S-21711E, “Military Specification, Shoes, Women's,” 3...
40 CFR Figure E-1 to Subpart E of... - Designation Testing Checklist
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Field Sampling Procedure (§ 53.30, .31, .34) Design Specification Tests Filter (L-6) Range of... Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II... Process or of Documented Evidence: Performance, Design or Application Spec. Corresponding to Sections of...
40 CFR Figure E-1 to Subpart E of... - Designation Testing Checklist
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Field Sampling Procedure (§ 53.30, .31, .34) Design Specification Tests Filter (L-6) Range of... Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II... Process or of Documented Evidence: Performance, Design or Application Spec. Corresponding to Sections of...
40 CFR Figure E-1 to Subpart E of... - Designation Testing Checklist
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Field Sampling Procedure (§ 53.30, .31, .34) Design Specification Tests Filter ( L-6) Range of... Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II... Process or of Documented Evidence: Performance, Design or Application Spec. Corresponding to Sections of...
Determining Indirect Cost Rates in Research Libraries. SPEC Kit 34.
ERIC Educational Resources Information Center
Association of Research Libraries, Washington, DC. Office of Management Studies.
This kit prepared by the Association of Research Libraries (ARL) contains 15 primary source documents on determining indirect cost rates in research libraries. The kit comprises: (1) six library cost studies and surveys, "Allocation of Library Expenditures to Research and Instruction" (University of Pennsylvania), "Sampling of Current Monograph…
Laser drilling of vias in dielectric for high density multilayer LSHI thick film circuits
NASA Technical Reports Server (NTRS)
Cocca, T.; Dakesian, S.
1977-01-01
A design analysis of a high density multilevel thick film digital microcircuit used for large scale integration is presented. The circuit employs 4 mil lines, 4 mil spaces and requires 4 mil diameter vias. Present screened and fired thick film technology is limited on a production basis to 16 mil square vias. A process whereby 4 mil diameter vias can be fabricated in production using laser technology was described along with a process to produce 4 mil diameter vias for conductor patterns which have 4 mil lines and 4 mil spacings.
Meaning in life in psychotherapy: The perspective of experienced psychotherapists.
Hill, Clara E; Kanazawa, Yoshi; Knox, Sarah; Schauerman, Iris; Loureiro, Darren; James, Danielle; Carter, Imani; King, Shakeena; Razzak, Suad; Scarff, Melanie; Moore, Jasmine
2017-07-01
Our goal was to explore the meaning experienced psychotherapists derive from providing psychotherapy, their beliefs about the role of meaning in life (MIL) in psychotherapy, how they worked with MIL with a client who explicitly presented concerns about MIL, and how they worked with a different client for whom MIL was a secondary and more implicit concern. Thirteen experienced psychotherapists were interviewed and data were analyzed using consensual qualitative research. Therapists derived self-oriented meaning (e.g., feeling gratified, fulfilled, connected) and other-oriented meaning (helping others, making the world a better place) from providing psychotherapy. They believed that MIL is fundamental and underlies all human concerns, including those brought to therapy. In contrast to the clients who had implicit MIL concerns, clients who explicitly presented MIL concerns were reported to have more interpersonal problems and physical problems, but about the same amount of psychological distress and loss/grief. Therapists used insight-oriented interventions, support, action-oriented interventions, and exploratory interventions to work with MIL with both types of clients, but used more exploratory interventions with implicit than explicit MIL clients. MIL is a salient topic for experienced, existentially oriented psychotherapists; they work with MIL extensively with some clients in psychotherapy. We recommend that therapists receive training to work with MIL in therapy, and that they pay attention to MIL concerns when they conduct psychotherapy. We also recommend additional research on MIL in psychotherapy.
Mini-Spec: A Compact, Fiber-Coupled, VPH Grating Spectrograph for Small Observatories
NASA Astrophysics Data System (ADS)
Nations, H. L.; Haynes, P.; Brewer, P.
2003-05-01
We report on the development and testing of what we believe to be the first VPH grating based spectrograph developed primarily for use at telescopes of modest aperture. To date, the most common instrument suite for such observatories is typically that of a CCD camera with attached filter wheel. While there is no doubt that a wide range of interesting and good science has been done with such instrumentation, the addition of a robust and easy to operate spectrograph would greatly increase the utility of such installations. While some commercial spectrographs exist for use on small telescopes, the authors have found them to be, with few exceptions, either inefficient, difficult for inexperienced students or amateurs to use, or not remotely operable. Correcting these deficiencies is thus the primary motivation for Mini-Spec. The design of Mini-Spec has been influenced by previous work the authors have done on a full-sized fiber-coupled spectrograph (Nations and Pierce, 2002). Mini-Spec uses some of those original design features, only reduced drastically in size. This size reduction (the spectrograph fits within a 7 inch cube), along with a much more careful choice of some critical components, has resulted in a dramatic reduction in cost. The spectrograph uses a highly efficient 1200 l/mm, 40 mm diameter vph grating on loan from Richard Rallison. Focus, central wavelength selection, and comparison lamps are all controlled via an RS-232 link and a custom Visual Basic GUI. Sample spectra of stellar and non-stellar targets will be presented along with a discussion of research projects admirably suited for this instrument. Funding for equipment has been provided by a NASA EPSCoR grant to PI Ron Canterna. HLN has been partially funded by a Wyoming Space Grant Faculty Fellowship.
Isotopic composition of carbon and hydrogen in some Apollo 14 and 15 lunar samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Friedman, I.; Hardcastle, K.G.; Gleason, J.D.
1974-01-01
Isotopic composition of carbon and hydrogen in some Apollo 14 and 15 lunar samples was determined by use of a newly constructed combustion line that yields low blanks for CO/sub 2/ and H/sub 2/. The results from combustion of fines and breccia from Apollo 14 lunar samples and of fines, breccia, and hasalt from Apollo 15 were compared with data obtained by heating samples in vacuo to over 1,350 deg C. The two techniques gave similar results. Total carbon in the flnes ranged from 51 to 110 p/m with a delta C/sup 13/ of 112 to --8 per mil (partsmore » per thousand) PDB. The breccias contain 22 to 50 p/m carbon with a delta C/sup 13/ of -21 to -25 per mil. The crystalline rock (sample 15555) has a carbon contert of about 7 p/m and a delta C/sup 13/ of --28 per mil. The total hydrogen in the fines ranges from 66 to 120 p/m with a (D/H) x 10/sup -6/ of 39 to 90. The breccias contain 8 to 38 p/m H/sub 2/ with a (D/H) x 10/sup -6/of 103 to 144. The crystalline rock contains about 2 p/m H/sub 2/ with a (D/H) x 10/sup -6/ of about 140. Arguments are presented to show that the contamination by Earth materials is not as serious a problem as has been proposed by previous authors. (auth)« less
USDA-ARS?s Scientific Manuscript database
We describe three new species of Rectiostoma Becker, 1982 from Costa Rica: R. annemayae Heikkilä and Metz spec. nov., R. eowilsoni Heikkilä and Metz spec. nov. and R. philipmayi Heikkilä and Metz spec. nov. We used a data set of DNA COI-barcodes accumulated for Lepidoptera collected at Area de Conse...
Multiple-instance ensemble learning for hyperspectral images
NASA Astrophysics Data System (ADS)
Ergul, Ugur; Bilgin, Gokhan
2017-10-01
An ensemble framework for multiple-instance (MI) learning (MIL) is introduced for use in hyperspectral images (HSIs) by inspiring the bagging (bootstrap aggregation) method in ensemble learning. Ensemble-based bagging is performed by a small percentage of training samples, and MI bags are formed by a local windowing process with variable window sizes on selected instances. In addition to bootstrap aggregation, random subspace is another method used to diversify base classifiers. The proposed method is implemented using four MIL classification algorithms. The classifier model learning phase is carried out with MI bags, and the estimation phase is performed over single-test instances. In the experimental part of the study, two different HSIs that have ground-truth information are used, and comparative results are demonstrated with state-of-the-art classification methods. In general, the MI ensemble approach produces more compact results in terms of both diversity and error compared to equipollent non-MIL algorithms.
Quantitative computed tomography applied to interstitial lung diseases.
Obert, Martin; Kampschulte, Marian; Limburg, Rebekka; Barańczuk, Stefan; Krombach, Gabriele A
2018-03-01
To evaluate a new image marker that retrieves information from computed tomography (CT) density histograms, with respect to classification properties between different lung parenchyma groups. Furthermore, to conduct a comparison of the new image marker with conventional markers. Density histograms from 220 different subjects (normal = 71; emphysema = 73; fibrotic = 76) were used to compare the conventionally applied emphysema index (EI), 15 th percentile value (PV), mean value (MV), variance (V), skewness (S), kurtosis (K), with a new histogram's functional shape (HFS) method. Multinomial logistic regression (MLR) analyses was performed to calculate predictions of different lung parenchyma group membership using the individual methods, as well as combinations thereof, as covariates. Overall correct assigned subjects (OCA), sensitivity (sens), specificity (spec), and Nagelkerke's pseudo R 2 (NR 2 ) effect size were estimated. NR 2 was used to set up a ranking list of the different methods. MLR indicates the highest classification power (OCA of 92%; sens 0.95; spec 0.89; NR 2 0.95) when all histogram analyses methods were applied together in the MLR. Highest classification power among individually applied methods was found using the HFS concept (OCA 86%; sens 0.93; spec 0.79; NR 2 0.80). Conventional methods achieved lower classification potential on their own: EI (OCA 69%; sens 0.95; spec 0.26; NR 2 0.52); PV (OCA 69%; sens 0.90; spec 0.37; NR 2 0.57); MV (OCA 65%; sens 0.71; spec 0.58; NR 2 0.61); V (OCA 66%; sens 0.72; spec 0.53; NR 2 0.66); S (OCA 65%; sens 0.88; spec 0.26; NR 2 0.55); and K (OCA 63%; sens 0.90; spec 0.16; NR 2 0.48). The HFS method, which was so far applied to a CT bone density curve analysis, is also a remarkable information extraction tool for lung density histograms. Presumably, being a principle mathematical approach, the HFS method can extract valuable health related information also from histograms from complete different areas. Copyright © 2018 Elsevier B.V. All rights reserved.
Kharadov, A V
2002-01-01
Aberrations (quantitative chaetotactic deviations, i.e. decreasing or increasing of setae numbers and variations in arrangement of setae) and anomalies (qualitative chaetotactic deviations, for example, partial reduction of scutum, shortening of a seta more than 1.5-2 times, merging of setae) were recorded for 13 taxonomically important morphological structures in the chigger mite species Neotrombicula sympatrica Stekolnikov, 2001. 3308 specimens were studied as a total. 17.2% of them had various morphological deviations. The most common types of aberrations were observed in the number and positions of genualae I (94 specimens), AM seta (79 spec.) and sternal setae (77 spec.). The aberrations of sternal and coxal setae were usually interrelated: the sternal seta was "transferred" from the sternal area onto the coxa, or the other way round take place. The specimens having aberrations of sternal setae were twice as numerous as the specimens with aberrations of coxal setae (77 against 35). The specimens with aberrations of dorsal setae and mastitarsala were very rare (2 spec. each). Among anomalies, the presence of nude galeal seta (91 spec.) and scutal anomalies (66 spec.) were prevalent. The most frequently one form of deviation only was observed in one specimen of N. sympatrica. Nevertheless, the specimens simultaneously having several aberrations or anomalies were also found. 17 types of such combinations were observed, that counts 20.6% of all specimens with deviations. Symmetric deviations, namely the presence of two nude galeal setae (31 spec.), presence of 2 genualae on both legs I (4 spec.), presence of 2 AM (2 spec.) and symmetric reduction of scutal angles (1 spec.), sometimes cause troubles in diagnostics. The quarter of variance in N. sympatrica and in the species N. monticola Schluger et Davydov, 1967 formerly studied by the author turned out as almost identical. The specimens with deviations counted 14.5% of all studied specimens in the latter species. However, the structures of variance in these species is different. In N. monticola, the aberrations of humeral setae were dominant (71.6%) (Kharadov, Chirov, 2001), while in N. sympatrica, the aberrations of other structures were prevalent: genualae I (24.8%), AM (20.9%) and sternal setae (20.4%).
iSAFT Protocol Validation Platform for On-Board Data Networks
NASA Astrophysics Data System (ADS)
Tavoularis, Antonis; Kollias, Vangelis; Marinis, Kostas
2014-08-01
iSAFT is an integrated powerful HW/SW environmentfor the simulation, validation & monitoring of satellite/spacecraft on-board data networks supporting simultaneously a wide range of protocols (RMAP, PTP, CCSDS Space Packet, TM/TC, CANopen, etc.) and network interfaces (SpaceWire, ECSS MIL-STD-1553, ECSS CAN). It is based on over 20 years of TELETEL's experience in the area of protocol validation in the telecommunications and aeronautical sectors, and it has been fully re-engineered in cooperation of TELETEL with ESA & space Primes, to comply with space on-board industrial validation requirements (ECSS, EGSE, AIT, AIV, etc.). iSAFT is highly modular and expandable to support new network interfaces & protocols and it is based on the powerful iSAFT graphical tool chain (Protocol Analyser / Recorder, TestRunner, Device Simulator, Traffic Generator, etc.).
Metallic positive expulsion diaphragms
NASA Technical Reports Server (NTRS)
Gleich, D.
1972-01-01
High-cycle life ring-reinforced hemispherical type positive expulsion diaphragm performance was demonstrated by room temperature fluid expulsion tests of 13" diameter, 8 mil thick stainless steel configurations. A maximum of eleven (11) leak-free, fluid expulsions were achieved by a 25 deg cone angle diaphragm hoop-reinforced with .110-inch cross-sectional diameter wires. This represents a 70% improvement in diaphragm reversal cycle life compared to results previously obtained. The reversal tests confirmed analytic predictions for diaphragm cycle life increases due to increasing values of diaphragm cone angle, radius to thickness ratio and material strain to necking capacity. Practical fabrication techniques were demonstrated for forming close-tolerance, thin corrugated shells and for obtaining closely controlled reinforcing ring stiffness required to maximize diaphragm cycle life. A non-destructive inspection technique for monitoring large local shell bending strains was developed.
NASA Astrophysics Data System (ADS)
Chen, Shuyi; Lu, Huigong; Wu, Yi-nan; Gu, Yifan; Li, Fengting; Morlay, Catherine
2016-09-01
Alumina-hercynite nano-spinel powders were prepared via one-step pyrolysis of iron-acetylacetone-doped Al-based metal-organic framework (MOF), i.e., MIL-53(Al). Organic ferric source, iron acetylacetone, was incorporated in situ into the framework of MIL-53(Al) during the solvothermal synthesis process. Under high-temperature pyrolysis, alumina derived from the MIL-53(Al) matrix and ferric oxides originated from the decomposition of organic ferric precursor in the framework were thermally converted into hercynite (FeAl2O4). The prepared samples were characterized using transmission electron microscopy, X-ray diffraction, N2 sorption, thermogravimetry, Raman spectroscopy and X-ray photoelectron spectroscopy. The final products were identified to be composed of alumina, hercynite and trace amounts of carbon depending on pyrolysis temperature. The experimental results showed that hercynite phase can be obtained and stabilized at low temperatures between 900 and 1100 °C under inert atmosphere. The final products were composed of nano-sized particles with an average size below 100 nm of individual crystal and specific surface areas of 18-49 m2 g-1.
A Comparative Study on the Meaning in Life of Patients with Cancer and Their Family Members.
Hassankhani, Hadi; Soheili, Amin; Hosseinpour, Issa; Eivazi Ziaei, Jamal; Nahamin, Mina
2017-12-01
Introduction: The overwhelming effects of cancer could be catastrophic for the patients and their family members, putting them at risk of experiencing uncertainty, loss, and an interruption in life. Also, it can influence their sense of meaning, a fundamental need equated with the purpose in life. Accordingly, this study aimed to compare the meaning in life (MiL) of patients with cancer and their family members. Methods: This descriptive comparative study was conducted on 400 patients with cancer and their family members admitted to university hospitals in Tabriz and Ardebil provinces, Iran. The participants were sampled conveniently and the Life Evaluation Questionnaire (LEQ) were used for collecting data analyzed through descriptive and inferential statistics in SPSS ver. 13 Software. Results: The mean score for the MiL of the patients with cancer and their family members was 119 (16.92) and 146.2 (17.07), respectively. There was a significant difference between patients with cancer and their family members in terms of MiL. Conclusion: The MiL of patients with cancer is lower than that of their family members, which indicates the need for further attention to the psychological processes and their modification in Iranian healthcare systems.
Shih, Yung-Han; Wang, Kuen-Yun; Singco, Brenda; Lin, Chia-Her; Huang, Hsi-Ya
2016-11-08
In this study, we first demonstrated the effect of two types of metal-organic framework-polymer (MOF-polymer) monoliths on in-tube solid-phase microextraction (IT-SPME) of sulfonamides. Sulfonamides were successfully adsorbed onto MIL-101(Cr)-polymer but were difficult to elute due to these sulfonamides could interact via Lewis acid-base interaction with the presence of Cr(III) coordinatively unsaturated metal sites (CUS). Moreover, the cage-type topology of MIL-101(Cr) that could produce multiple pathways thus complicates the desorption of the test analytes from the sorbent. Contrastingly, MIL-53(Al)-polymer provided weaker Al(III) CUS, and its one-dimensional channel pore structure could provide an unhindered pathway for sulfonamides transfer during elution. After optimizing the IT-SPME condition such as MOF content, pH of sample matrix, column length, extraction flow rate, and elution volume, the calculated extraction recovery of sulfonamides in MIL-53(Al)-polymer as analyzed by microemulsion electrokinetic chromatography (MEEKC) were in the range of 40%-90% with relative standard deviations (RSDs) below 5% and a reusability of at least 30 times.
NASA Technical Reports Server (NTRS)
Roskam, Jan; Ackers, Deane E.; Gerren, Donna S.
1995-01-01
A propulsion controlled aircraft (PCA) system has been developed at NASA Dryden Flight Research Center at Edwards Air Force Base, California, to provide safe, emergency landing capability should the primary flight control system of the aircraft fail. As a result of the successful PCA work being done at NASA Dryden, this project investigated the possibility of incorporating the PCA system as a backup flight control system in the design of a large, ultra-high capacity megatransport in such a way that flight path control using only the engines is not only possible, but meets MIL-Spec Level 1 or Level 2 handling quality requirements. An 800 passenger megatransport aircraft was designed and programmed into the NASA Dryden simulator. Many different analysis methods were used to evaluate the flying qualities of the megatransport while using engine thrust for flight path control, including: (1) Bode and root locus plot analysis to evaluate the frequency and damping ratio response of the megatransport; (2) analysis of actual simulator strip chart recordings to evaluate the time history response of the megatransport; and (3) analysis of Cooper-Harper pilot ratings by two NaSA test pilots.
Techniques for designing rotorcraft control systems
NASA Technical Reports Server (NTRS)
Levine, William S.; Barlow, Jewel
1993-01-01
This report summarizes the work that was done on the project from 1 Apr. 1992 to 31 Mar. 1993. The main goal of this research is to develop a practical tool for rotorcraft control system design based on interactive optimization tools (CONSOL-OPTCAD) and classical rotorcraft design considerations (ADOCS). This approach enables the designer to combine engineering intuition and experience with parametric optimization. The combination should make it possible to produce a better design faster than would be possible using either pure optimization or pure intuition and experience. We emphasize that the goal of this project is not to develop an algorithm. It is to develop a tool. We want to keep the human designer in the design process to take advantage of his or her experience and creativity. The role of the computer is to perform the calculation necessary to improve and to display the performance of the nominal design. Briefly, during the first year we have connected CONSOL-OPTCAD, an existing software package for optimizing parameters with respect to multiple performance criteria, to a simplified nonlinear simulation of the UH-60 rotorcraft. We have also created mathematical approximations to the Mil-specs for rotorcraft handling qualities and input them into CONSOL-OPTCAD. Finally, we have developed the additional software necessary to use CONSOL-OPTCAD for the design of rotorcraft controllers.
Liang, Li; Wang, Xinghua; Sun, Ying; Ma, Pinyi; Li, Xinpei; Piao, Huilan; Jiang, Yanxiao; Song, Daqian
2018-03-01
The metal-organic framework (MOF) functionalized magnetic graphene oxide/mesoporous silica composites (Fe 3 O 4 @SiO 2 -GO/MIL-101(Cr)) were synthesized and utilized as magnetic solid-phase extraction (MSPE) adsorbent for the extraction of seven triazine herbicides (terbuthylazine, secbumeton, terbumeton, atraton, atrazine, prometon and trietazine) in rice samples. Several experimental parameters, including type and volume of extraction solvent, amount of MIL-101(Cr), extraction time, volume of desorption solvent and desorption time were investigated and optimized. The limits of detection (LODs) of seven triazine herbicides obtained by using the proposed MSPE method combined with high performance liquid chromatography (HPLC) were in the range of 0.010-0.080µgkg -1 . The recoveries of the triazine herbicides in spiked rice samples ranged from of 83.9-103.5% with the relative standard deviations lower than 8.7%. The intra and inter-day (n = 6) precisions for all triazine herbicides at the spiked level of 100.0µgkg -1 were 1.4-5.9% and 2.6-7.8%, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.
Zheng, Shu; Xiao, Zuo-Xiang; Pan, Yue-Long; Han, Ming-Yong; Dong, Qi
2003-01-01
AIM: To explore the anti-tumor immunity against CT26 colon tumor of the microencapsulated cells modified with murine interleukine-12 (mIL-12) gene. METHODS: Mouse fibroblasts (NIH3T3) were stably transfected to express mIL-12 using expression plasmids carrying mIL-12 gene (p35 and p40), and NIH3T3-mIL-12 cells were encapsulated in alginate microcapsules for long-term delivery of mIL-12. mIL-12 released from the microencapsulated NIH3T3-mIL-12 cells was confirmed using ELISA assay. Transplantation of the microencapsulated NIH3T3-mIL-12 cells was performed in the tumor-bearing mice with CT26 cells. The anti-tumor responses and the anti-tumor activities of the microencapsulated NIH3T3-mIL-12 cells were evaluated. RESULTS: Microencapsulated NIH3T3-mIL-12 cells could release mIL-12 continuously and stably for a long time. After the microencapsulated NIH3T3-mIL-12 cells were transplanted subcutaneously into the tumor-bearing mice for 21 d, the serum concentrations of mIL-12, mIL-2 and mIFN-γ, the cytotoxicity of the CTL from the splenocytes and the NK activity in the treatment group were significantly higher than those in the controls. Moreover, mIL-12 released from the microencapsulated NIH3T3-mIL-12 cells resulted in a significant inhibition of tumor proliferation and a prolonged survival of tumor-bearing mice. CONCLUSION: The microencapsulated NIH3T3-mIL-12 cells have a significant therapeutic effect on the experimental colon tumor by activating anti-tumor immune responses in vivo. Microencapsulated and genetically engineered cells may be an extremely versatile tool for tumor gene therapy. PMID:12717836
Compressive and Flexural Tests on Adobe Samples Reinforced with Wire Mesh
NASA Astrophysics Data System (ADS)
Jokhio, G. A.; Al-Tawil, Y. M. Y.; Syed Mohsin, S. M.; Gul, Y.; Ramli, N. I.
2018-03-01
Adobe is an economical, naturally available, and environment friendly construction material that offers excellent thermal and sound insulations as well as indoor air quality. It is important to understand and enhance the mechanical properties of this material, where a high degree of variation is reported in the literature owing to lack of research and standardization in this field. The present paper focuses first on the understanding of mechanical behaviour of adobe subjected to compressive stresses as well as flexure and then on enhancing the same with the help of steel wire mesh as reinforcement. A total of 22 samples were tested out of which, 12 cube samples were tested for compressive strength, whereas 10 beams samples were tested for modulus of rupture. Half of the samples in each category were control samples i.e. without wire mesh reinforcement, whereas the remaining half were reinforced with a single layer of wire mesh per sample. It has been found that the compressive strength of adobe increases by about 43% after adding a single layer of wire mesh reinforcement. The flexural response of adobe has also shown improvement with the addition of wire mesh reinforcement.
Gavin, Patrick J.; Peterson, Lance R.; Pasquariello, Anna C.; Blackburn, Joanna; Hamming, Mark G.; Kuo, Kuo J.; Thomson, Richard B.
2004-01-01
Shiga toxin-producing Escherichia coli bacteria (STEC) are emerging pathogens capable of producing sporadic and epidemic diarrhea, hemorrhagic colitis, and potentially life-threatening hemolytic-uremic syndrome. Although the presence of E. coli O157 can be readily detected in stool by sorbitol-MacConkey agar culture (SMAC), STEC non-O157 serotypes cannot. In contrast to culture, testing for the presence of Shiga toxins 1 and 2 in stool detects both O157 and non-O157 STEC serotypes capable of causing disease. Over two consecutive summers, we evaluated the performance of the ProSpecT Shiga toxin E. coli Microplate assay (Alexon-Trend, Ramsey, Minn.), an enzyme immunoassay for the detection of Shiga toxins 1 and 2, on all stools submitted for culture of enteric pathogens, and the potential clinical impact of Shiga toxin detection. Twenty-nine stool specimens were STEC positive by ProSpecT assay. Twenty-seven of 29 STEC-positive isolates were confirmed by SMAC and serotyping or by a second enzyme immunoassay and PCR (positive predictive value, 93%). Thirteen of 27 confirmed Shiga toxin-producing strains were serotype O157. The remaining 14 strains represented 8 other serotypes. The ProSpecT assay was 100% sensitive and specific for detection of E. coli O157 in stool (7 of 7) compared to SMAC. In addition, the ProSpecT assay detected twice as many STEC as SMAC. Fifty-two percent of confirmed STEC-positive stools were nonbloody. Thus, in our population, screening strategies that test only visibly bloody stools for STEC would miss a majority of cases. Eleven (41%) STEC-positive patients were hospitalized, and eight (30%) developed severe disease (two developed hemolytic-uremic syndrome, and six developed hemorrhagic colitis). Prior to detection of STEC infection, seven (26%) and eight patients (30%) underwent unnecessary diagnostic procedures or received potentially deleterious empirical treatment, respectively. We propose that establishing a specific diagnosis of STEC may have prevented these potentially harmful interventions. We conclude that the ProSpecT assay is sensitive and specific for the detection of Shiga toxins 1 and 2 in stool and has potentially significant clinical impact for the individual patient and public health. Shiga toxin assays should be considered for routine use in settings where prevalence of STEC disease warrants testing. PMID:15071021
Fiorentini, Emiliano F; Escudero, Leticia B; Wuilloud, Rodolfo G
2018-04-19
A simple, highly efficient, batch, and centrifuge-less dispersive liquid-liquid microextraction method based on a magnetic ionic liquid (MIL-DLLME) and electrothermal atomic absorption spectrometry (ETAAS) detection was developed for ultra-trace Cd determination in honey. Initially, Cd(II) was chelated with ammonium diethyldithiophosphate (DDTP) at pH 0.5 followed by its extraction with the MIL trihexyl(tetradecyl)phosphonium tetrachloroferrate(III) ([P 6,6,6,14 ]FeCl 4 ) and acetonitrile as dispersant. The MIL phase containing the analyte was separated from the aqueous phase using only a magnet. A back-extraction procedure was applied to recover Cd from the MIL phase using diluted HNO 3 and this solution was directly injected into the graphite furnace of ETAAS instrument. An extraction efficiency of 93% and a sensitivity enhancement factor of 112 were obtained under optimal experimental conditions. The detection limit (LOD) was 0.4 ng L -1 Cd, while the relative standard deviation (RSD) was 3.8% (at 2 μg L -1 Cd and n = 10), calculated from the peak height of absorbance signals. This work reports the first application of the MIL [P 6,6,6,14 ]FeCl 4 along with the DLLME technique for the successful determination of Cd at trace levels in different honey samples. Graphical abstract Preconcentration of ultratraces of Cd in honey using a magnetic ionic liquid and dispersive liquid-liquid microextraction technique.
Usability study of a novel, self-lighted, disposable speculum: military applications.
Jones, Christina L; Gruber, Daniel D; Warner, William; Buller, Jerome L
2013-04-01
Data collected from a postutilization questionnaire were used to evaluate the usability of the OfficeSPEC disposable vaginal speculum, specifically the effectiveness, efficiency, and acceptability, in clinical, hospital, and austere environments. Usability data analysis showed the OfficeSPEC speculum had an effectiveness rating of 4.6/5, efficiency rating of 4.5/5, and acceptability rating of 4.6/5; overall usability in deployed environments was favorable. The overall rankings were 3.4 for plastic, 4.2 for metal (p < 0.001), and 4.5 for OfficeSPEC (p < 0.001). Cost analysis of the OfficeSPEC placed the disposable speculum as a reasonable alternative with yearly cost of $129,200, compared to traditional metal ($209,100) and plastic ($319,175). By evaluating the OfficeSPEC speculum within a usability framework, it proved to be practical, viable alternative in all environments, particularly in the forward deployed environment. Reprint & Copyright © 2013 Association of Military Surgeons of the U.S.
Seo, Pill Won; Khan, Nazmul Abedin; Hasan, Zubair; Jhung, Sung Hwa
2016-11-02
A highly porous metal-organic framework (MOF), MIL-101, was modified to introduce urea or melamine via grafting on open metal sites of the MOF. Adsorptive removal of three artificial sweeteners (ASWs) was studied using the MOFs, with or without modifications (including nitration), and activated carbon (AC). The adsorbed quantities (based on the weight of the adsorbent) of saccharin (SAC) under various conditions decreased in the order urea-MIL-101 > melamine-MIL-101 > MIL-101 > AC > O 2 N-MIL-101; however, the quantities based on unit surface area are in the order melamine-MIL-101 > urea-MIL-101 > MIL-101 > O 2 N-MIL-101. Similar ASWs [acesulfame (ACE) and cyclamate (CYC)] showed the same tendency. The mechanism for very favorable adsorption of SAC, ACE, and CYC over urea- and melamine-MIL-101 could be explained by H-bonding on the basis of the contents of -NH 2 groups on the MOFs and the adsorption results under a wide range of pH values. Moreover, the direction of H-bonding could be clearly defined (H acceptor: ASWs; H donor: MOFs). Urea-MIL-101 and melamine-MIL-101 could be suggested as competitive adsorbents for organic contaminants (such as ASWs) with electronegative atoms, considering their high adsorption capacity (for example, urea-MIL-101 had 2.3 times the SAC adsorption of AC) and ready regeneration.
2012-08-27
materials Examples: - Cheese whey , molasses, compost, or off-spec food products for inducing anaerobic conditions - Crushed concrete for use as...place of refined chemicals or materials Examples: - Cheese whey , molasses, compost, or off-spec food products for inducing anaerobic conditions... whey , molasses, compost, or off-spec food products for inducing anaerobic conditions - Crushed concrete for use as fill - Concrete from coal
ChinaSpec: a network of SIF observations to bridge flux measurements and remote sensing data
NASA Astrophysics Data System (ADS)
Zhang, Y.; Wang, S.; Liu, L.; Ju, W.; Zhu, X.
2017-12-01
Accurately quantifying atmosphere-biosphere interactions across multiple scale still remains a challenge. Remote sensing, especially satellite data, has been widely used as a solution to resolve the broad scale estimation of carbon flux by upscaling the point measurements of eddy covariance (EC) technique. However, critical gaps remain between the EC observations and coarse satellite data due to the scale mismatch. In this regard, it is necessary to build a network of in situ optical observations to bridge the scale-mismatch between EC measurements and satellite remote sensing data. Internationally, a few networks have already been established (e.g., SpecNet and EuroSpec), but still at its early stage. ChinaSpec is a network of linking in situ spectral measurements, especially sun-induce chlorophyll fluorescence (SIF), with point EC observations for better understanding the interactions of atmosphere-biosphere. One main focus of ChinsSpec is to conduct continuous field SIF measurements at multiple EC sites across the mainland of China. This will help us better understand the mechanics of SIF and photosynthesis, and resolve the missing gaps between recent SIF retrievals from coarse satellite data and EC observations. In this presentation, we introduce the background, current stage, and the development of ChinaSpec network.
Repercussion of noni mouthwash on surface characterization of Nickel-Titanium archwire.
Dilipkumar, Dhivya; Dhinahar, S; Deenadayalan, P; Tandon, Akshay; Suresh, Poonkuzhali
2017-01-01
Maintaining oral hygiene is very important during orthodontic therapy mouthwashes are prescribed as an adjunct to improve patient's oral hygiene. Commercially available mouthwashes e.g. Chlorhexidine, Listerine, fluoride containing mouthwashes have shown to alter the surface characteristics of orthodontic wires. Hence the purpose of the study was to evaluate the effect of Noni mouthwash on surface quality and compositional changes of Nickel Titanium orthodontic wires. In this in vitro study pre-formed 0.014 inch NiTi arch wire was used. The study comprised of two samples, one control and one test sample which were 25mm in length. Control sample was stored at room temperature without any manipulation while test sample was immersed in Noni mouthwash solution for 1.5 hours, after which the test specimen was removed from the mouthwash solution and rinsed with distilled water. Both control and test samples were sent for scanning electron microscopy analysis, to qualitatively characterize the topography of the wire surface. Electron dispersion spectrum analysis was done to evaluate the various components of both the wires. No significant difference in the average surface roughness for both wire samples was observed. There was no significant difference seen in the composition of wire after immersion in Noni mouthwash. Noni mouthwash did not have significant influence on the surface roughness or altered the composition of the Ni-Ti wire. Hence Noni mouthwash may be prescribed as a natural, non-destructive prophylactic agent for orthodontic patients.
SpecViz: Interactive Spectral Data Analysis
NASA Astrophysics Data System (ADS)
Earl, Nicholas Michael; STScI
2016-06-01
The astronomical community is about to enter a new generation of scientific enterprise. With next-generation instrumentation and advanced capabilities, the need has arisen to equip astronomers with the necessary tools to deal with large, multi-faceted data. The Space Telescope Science Institute has initiated a data analysis forum for the creation, development, and maintenance of software tools for the interpretation of these new data sets. SpecViz is a spectral 1-D interactive visualization and analysis application built with Python in an open source development environment. A user-friendly GUI allows for a fast, interactive approach to spectral analysis. SpecViz supports handling of unique and instrument-specific data, incorporation of advanced spectral unit handling and conversions in a flexible, high-performance interactive plotting environment. Active spectral feature analysis is possible through interactive measurement and statistical tools. It can be used to build wide-band SEDs, with the capability of combining or overplotting data products from various instruments. SpecViz sports advanced toolsets for filtering and detrending spectral lines; identifying, isolating, and manipulating spectral features; as well as utilizing spectral templates for renormalizing data in an interactive way. SpecViz also includes a flexible model fitting toolset that allows for multi-component models, as well as custom models, to be used with various fitting and decomposition routines. SpecViz also features robust extension via custom data loaders and connection to the central communication system underneath the interface for more advanced control. Incorporation with Jupyter notebooks via connection with the active iPython kernel allows for SpecViz to be used in addition to a user’s normal workflow without demanding the user drastically alter their method of data analysis. In addition, SpecViz allows the interactive analysis of multi-object spectroscopy in the same straight-forward, consistent way. Through the development of such tools, STScI hopes to unify astronomical data analysis software for JWST and other instruments, allowing for efficient, reliable, and consistent scientific results.
NASA Astrophysics Data System (ADS)
Li, Xianghui; Guo, Weilin; Liu, Zhonghua; Wang, Ruiqin; Liu, Hua
2016-04-01
Fe-based metal-organic frameworks (MOFs) including MIL-101(Fe), MIL-100(Fe), MIL-53(Fe), and MIL-88B(Fe) prepared via a facile solvothermal process were introduced as both adsorbents and catalysts to generate powerful radicals from persulfate for acid orange 7 (AO7) removal in aqueous solution. Various catalysts were described and characterized by X-ray diffraction, Fourier transform infrared spectroscopy, scanning electron microscopy and X-ray photoelectron spectra. Because of the high specific surface area of the materials, we studied the adsorption isotherms of the four MILs by the fitting of Langmuir adsorption isotherm. Meanwhile, the catalytic activities in persulfate oxidation system were investigated. The results showed that the sequence of the materials ability in the combination of adsorption and degradation was MIL-101(Fe) > MIL-100(Fe) > MIL-53(Fe) > MIL-88B(Fe), which had a close connection with the activity of metal ion in active site of the catalysts and their different cages in size. Moreover, the reactive species in MILs/persulfate system were identified as sulfate radicals and hydroxyl radicals. The reaction mechanism for persulfate activation over MILs was also studied.
High efficiency removal of triclosan by structure-directing agent modified mesoporous MIL-53(Al).
Dou, Rongni; Zhang, Junya; Chen, Yuancai; Feng, Siyuan
2017-03-01
In order to expand the potential applications of metal-organic frameworks (MOFs), structure directing agents modified mesoporous MIL-53(Al) (MIL-53(Al)-1) was investigated to adsorb triclosan (TCS) with two different initial concentrations. MIL-53(Al)-1 with high mesoporosity and total pore volume exhibited higher adsorption capacity and 4.4 times faster adsorption of TCS at low concentration (1 mg L -1 ) than that of microporous MIL-53(Al). Also, mesoporous as well as microporous MIL-53(Al) showed significant higher adsorption capacity and two orders of magnitude greater fast uptake of TCS than two kinds of mesoporous-activated carbon. The adsorption of TCS onto MIL-53(Al)-1 released more energy and had higher disorderliness than TCS on MIL-53(Al). The superior adsorption characteristics of MIL-53(Al)-1 were preserved over a wide pH range (4-9), at high concentration of ionic strengths, and in the presence of coexisting compounds (anions, cations, phenol, aniline, and humic acid). The selectivity adsorption and Fourier transform infrared (FT-IR) spectra revealed that TCS adsorption on MIL-53(Al)s was mainly driven by hydrophobicity interaction assisted with hydrogen bonding on MIL-53(Al)s. MIL-53(Al)s can be effectively regenerated several times by washing with 90% methanol-water (pH 11). All of the above results demonstrated MIL-53(Al)s are promising adsorbents for water purification. Graphical abstract.
Thermometry of the system “heat-resistant sample - incident plasma stream”
NASA Astrophysics Data System (ADS)
Sargsyan, M. A.; Chinnov, V. F.; Kavyrshin, D. I.; Gadzhiev, M. Kh; Khromov, M. A.; Chistolinov, A. V.; Senchenko, V. N.
2017-11-01
To study the interacting system “heat-resistant sample - an incident plasma stream” a setup of synchronized measurement equipment was developed and tested that recorded the main parameters of such interaction. Heat resistance tests were carried out on the samples of MPG-6 grade isotropic graphite, and samples of pyrolytic graphite that were subjected to a long (60 … 100 s) exposure to nitrogen, argon and air plasma streams at atmospheric pressure. As plasma generators a series of plasma torches with a vortex stabilization of the stream and an expanding anode channels was used. The temperature and composition of the plasma in the jet and near the sample were determined using two AvaSpec2048 and AvaSpec3648 scanning optical spectrometers and the MS5402i spectrograph with the Andor matrix at its outlet. The surface temperature of the sample was determined in real time using three independent ways: two pyrometric systems - a high-speed micro-pyrometer FMP1001 and a two-position visualization of the heated sample by high-speed Motion Pro X3 and VS-FAST cameras, and the spectral analysis of the wide-range thermal radiation of the samples. The main method for determining the rate of material loss during the action of a plasma jet on it was to analyze a two-position synchronous visualization of the “jet-sample” system. When a crater was formed on the surface of the sample under the “dagger” effect of a plasma jet, a video recording system of the crater zone was used, backlit using the “laser knife” method.
SEM evaluation of metallization on semiconductors. [Scanning Electron Microscope
NASA Technical Reports Server (NTRS)
Fresh, D. L.; Adolphsen, J. W.
1974-01-01
A test method for the evaluation of metallization on semiconductors is presented and discussed. The method has been prepared in MIL-STD format for submittal as a proposed addition to MIL-STD-883. It is applicable to discrete devices and to integrated circuits and specifically addresses batch-process oriented defects. Quantitative accept/reject criteria are given for contact windows, other oxide steps, and general interconnecting metallization. Figures are provided that illustrate typical types of defects. Apparatus specifications, sampling plans, and specimen preparation and examination requirements are described. Procedures for glassivated devices and for multi-metal interconnection systems are included.
Metallurgical investigation of wire breakage of tyre bead grade.
Palit, Piyas; Das, Souvik; Mathur, Jitendra
2015-10-01
Tyre bead grade wire is used for tyre making application. The wire is used as reinforcement inside the polymer of tyre. The wire is available in different size/section such as 1.6-0.80 mm thin Cu coated wire. During tyre making operation at tyre manufacturer company, wire failed frequently. In this present study, different broken/defective wire samples were collected from wire mill for detailed investigation of the defect. The natures of the defects were localized and similar in nature. The fracture surface was of finger nail type. Crow feet like defects including button like surface abnormalities were also observed on the broken wire samples. The defect was studied at different directions under microscope. Different advanced metallographic techniques have been used for detail investigation. The analysis revealed that, white layer of surface martensite was formed and it caused the final breakage of wire. In this present study we have also discussed about the possible reason for the formation of such kind of surface martensite (hard-phase).
Ardin, Maude; Cahais, Vincent; Castells, Xavier; Bouaoun, Liacine; Byrnes, Graham; Herceg, Zdenko; Zavadil, Jiri; Olivier, Magali
2016-04-18
The nature of somatic mutations observed in human tumors at single gene or genome-wide levels can reveal information on past carcinogenic exposures and mutational processes contributing to tumor development. While large amounts of sequencing data are being generated, the associated analysis and interpretation of mutation patterns that may reveal clues about the natural history of cancer present complex and challenging tasks that require advanced bioinformatics skills. To make such analyses accessible to a wider community of researchers with no programming expertise, we have developed within the web-based user-friendly platform Galaxy a first-of-its-kind package called MutSpec. MutSpec includes a set of tools that perform variant annotation and use advanced statistics for the identification of mutation signatures present in cancer genomes and for comparing the obtained signatures with those published in the COSMIC database and other sources. MutSpec offers an accessible framework for building reproducible analysis pipelines, integrating existing methods and scripts developed in-house with publicly available R packages. MutSpec may be used to analyse data from whole-exome, whole-genome or targeted sequencing experiments performed on human or mouse genomes. Results are provided in various formats including rich graphical outputs. An example is presented to illustrate the package functionalities, the straightforward workflow analysis and the richness of the statistics and publication-grade graphics produced by the tool. MutSpec offers an easy-to-use graphical interface embedded in the popular Galaxy platform that can be used by researchers with limited programming or bioinformatics expertise to analyse mutation signatures present in cancer genomes. MutSpec can thus effectively assist in the discovery of complex mutational processes resulting from exogenous and endogenous carcinogenic insults.
Berry, L M; Adams, R; Airey, M; Bracher, M G; Bourne, T; Carrington, B; Cross, A S; Davies, G C G; Finney, H M; Foulkes, R; Gozzard, N; Griffin, R A; Hailu, H; Lamour, S D; Lawson, A D; Lightwood, D J; McKnight, A J; O'Dowd, V L; Oxbrow, A K F; Popplewell, A G; Shaw, S; Stephens, P E; Sweeney, B; Tomlinson, K L; Uhe, C; Palframan, R T
2009-02-01
Interleukin-13 (IL-13) sequentially binds to IL-13Ralpha1 and IL-4Ralpha forming a high affinity signalling complex. This receptor complex is expressed on multiple cell types in the airway and signals through signal transducer and activator of transcription factor-6 (STAT-6) to stimulate the production of chemokines, cytokines and mucus. Antibodies have been generated, using the UCB Selected Lymphocyte Antibody Method (UCB SLAM), that block either binding of murine IL-13 (mIL-13) to mIL-13Ralpha1 and mIL-13Ralpha2, or block recruitment of mIL-4Ralpha to the mIL-13/mIL-13Ralpha1 complex. Monoclonal antibody (mAb) A was shown to bind to mIL-13 with high affinity (K(D) 11 pM) and prevent binding of mIL-13 to mIL-13Ralpha1. MAb B, that also bound mIL-13 with high affinity (K(D) 8 pM), was shown to prevent recruitment of mIL-4Ralpha to the mIL-13/mIL-13Ralpha1 complex. In vitro, mAbs A and B similarly neutralised mIL-13-stimulated STAT-6 activation and TF-1 cell proliferation. In vivo, mAbs A and B demonstrated equipotent, dose-dependent inhibition of eotaxin generation in mice stimulated by intraperitoneal administration of recombinant mIL-13. In an allergic lung inflammation model in mice, mAbs A and B equipotently inhibited muc5ac mucin mRNA upregulation in lung tissue measured two days after intranasal allergen challenge. These data support the design of therapeutics for the treatment of allergic airway disease that inhibits assembly of the high affinity IL-13 receptor signalling complex, by blocking the binding of IL-13 to IL-13Ralpha1 and IL-13Ralpha2, or the subsequent recruitment of IL-4Ralpha.
Liang, Yafei; Wang, Xuewan; Wu, Mianbin; Zhu, Wanping
2011-01-01
In this work, simultaneous isolation of lactoferrin (Lf) and lactoperoxidase (Lp) from defatted bovine colostrum by one-step cation exchange chromatography with SPEC 70 SLS ion-exchange resin was investigated. A RP-HPLC method for Lf and Lp determination was developed and optimized as the following conditions: detection wavelength of 220 nm, flow rate of 1 mL/min and acetonitrile concentration from 25% to 75% within 20 min. The adsorption process of Lf on SPEC 70 SLS resin was optimized using Lf standard as substrate. The maximum static binding capacity of SPEC 70 SLS resin was of 22.0 mg/g resin at 15 °C, pH 7.0 and adsorption time 3 h. The Lf adsorption process could be well described by the Langmuir adsorption isotherm model, with a maximum adsorption capacity of 21.73 mg/g resin at 15 °C. In batch fractionation of defatted colostrum, the binding capacities of SPEC 70 SLS resin for adsorbing Lf and Lp simultaneously under the abovementioned conditions were 7.60 and 6.89 mg/g resin, respectively, both of which were superior to those of CM Sepharose F.F. or SP Sepharose F.F. resins under the same conditions. As a result, SPEC 70 SLS resin was considered as a successful candidate for direct and economic purification of Lf and Lp from defatted colostrum. PMID:22016715
2011-01-01
Dawn.Nida@us.army.mil) Joshua Magnone (Joshua.Magnone@us.army.mil) Andre Senecal (Andy.Senecal@us.army.mil) ISSN 1477-3155 Article type Research Submission...Dawn.Nida@us.army.mil; Joshua Magnone - Joshua.Magnone@us.army.mil; Andre Senecal - Andy.Senecal@us.army.mil *Corresponding Author 2...Biol Eng 2007, 1:doi10.1186/1754-1611-1-2. 12. Senecal A, Magnone J, Marek P, Senecal K: Development of functional nanofibrous membrane assemblies
Seeing the light: The SpecUP educational spectrophotometer
NASA Astrophysics Data System (ADS)
Forbes, P. B. C.
2016-09-01
Spectrophotometry is a cross-cutting analytical technique, which finds use in disciplines ranging from chemistry to pharmacy, biochemistry, food science and physics. The SpecUP (Spectrophotometer of the University of Pretoria) is an educational spectrophotometer which was developed so that students could build their own instruments from components in a kit, and then utilise it to generate analytically useful results. This initiative allows for institutions to have more spectroscopy equipment available, as the SpecUP costs less than 40 as opposed to 2 000 which is the cost of an entry-level commercial instrument. This is of particular importance in a developing country context, where student numbers are typically high and resources are scarce. In addition, the SpecUP has moving parts and an open design which allows users to understand what is inside the "black box" of commercial instruments and to discover what happens when they adjust components, allowing for active, inquiry-based learning. The SpecUP user network currently spans South Africa, Tunisia, Namibia, Lesotho, Botswana, Kenya, Swaziland, Zimbabwe, Zambia, Ivory Coast, Egypt, Turkey and Italy.
NASA Technical Reports Server (NTRS)
Leveson, Nancy G.; Heimdahl, Mats P. E.; Reese, Jon Damon
1999-01-01
Previously, we defined a blackbox formal system modeling language called RSML (Requirements State Machine Language). The language was developed over several years while specifying the system requirements for a collision avoidance system for commercial passenger aircraft. During the language development, we received continual feedback and evaluation by FAA employees and industry representatives, which helped us to produce a specification language that is easily learned and used by application experts. Since the completion of the PSML project, we have continued our research on specification languages. This research is part of a larger effort to investigate the more general problem of providing tools to assist in developing embedded systems. Our latest experimental toolset is called SpecTRM (Specification Tools and Requirements Methodology), and the formal specification language is SpecTRM-RL (SpecTRM Requirements Language). This paper describes what we have learned from our use of RSML and how those lessons were applied to the design of SpecTRM-RL. We discuss our goals for SpecTRM-RL and the design features that support each of these goals.
A Comparative Study on the Meaning in Life of Patients with Cancer and Their Family Members
Hassankhani, Hadi; Soheili, Amin; Hosseinpour, Issa; Eivazi Ziaei, Jamal; Nahamin, Mina
2017-01-01
Introduction: The overwhelming effects of cancer could be catastrophic for the patients and their family members, putting them at risk of experiencing uncertainty, loss, and an interruption in life. Also, it can influence their sense of meaning, a fundamental need equated with the purpose in life. Accordingly, this study aimed to compare the meaning in life (MiL) of patients with cancer and their family members. Methods: This descriptive comparative study was conducted on 400 patients with cancer and their family members admitted to university hospitals in Tabriz and Ardebil provinces, Iran. The participants were sampled conveniently and the Life Evaluation Questionnaire (LEQ) were used for collecting data analyzed through descriptive and inferential statistics in SPSS ver. 13 Software. Results: The mean score for the MiL of the patients with cancer and their family members was 119 (16.92) and 146.2 (17.07), respectively. There was a significant difference between patients with cancer and their family members in terms of MiL. Conclusion: The MiL of patients with cancer is lower than that of their family members, which indicates the need for further attention to the psychological processes and their modification in Iranian healthcare systems PMID:29302572
Design and Performance of A High Resolution Micro-Spec: An Integrated Sub-Millimeter Spectrometer
NASA Technical Reports Server (NTRS)
Barrentine, Emily M.; Cataldo, Giuseppe; Brown, Ari D.; Ehsan, Negar; Noroozian, Omid; Stevenson, Thomas R.; U-Yen, Kongpop; Wollack, Edward J.; Moseley, S. Harvey
2016-01-01
Micro-Spec is a compact sub-millimeter (approximately 100 GHz--1:1 THz) spectrometer which uses low loss superconducting microstrip transmission lines and a single-crystal silicon dielectric to integrate all of the components of a diffraction grating spectrometer onto a single chip. We have already successfully evaluated the performance of a prototype Micro-Spec, with spectral resolving power, R=64. Here we present our progress towards developing a higher resolution Micro-Spec, which would enable the first science returns in a balloon flight version of this instrument. We describe modifications to the design in scaling from a R=64 to a R=256 instrument, as well as the ultimate performance limits and design concerns when scaling this instrument to higher resolutions.
NASA Technical Reports Server (NTRS)
Morris, R. V.; McKay, G. A.; Agresti, D. G.; Li, Loan
2008-01-01
Martian meteorite MIL03346 is described as an augite-rich cumulate rock with approx.80%, approx.3%, and approx.21% modal phase proportions of augite (CPX), olivine and glassy mesostasis, respectively, and is classified as a nakhlite [1]. The Mossbauer spectrum for whole rock (WR) MIL 03346 is unusual for Martian meteorites in that it has a distinct magnetite subspectrum (7% subspectral area) [2]. The meteorite also has products of pre-terrestrial aqueous alteration ("iddingsite") that is associated primarily with the basaltic glass and olivine. The Mossbauer spectrometers on the Mars Exploration Rovers have measured the Fe oxidation state and the Fe mineralogical composition of rocks and soils on the planet s surface since their landing in Gusev Crater and Meridiani Planum in January, 2004 [3,4]. The MIL 03346 meteorite provides an opportunity to "ground truth" or refine Fe phase identifications. This is particularly the case for the so-called "nanophase ferric oxide" (npOx) component. NpOx is a generic name for a ferric rich product of oxidative alteration. On Earth, where we can take samples apart and study individual phases, examples of npOx include ferrihydrite, schwertmannite, akagaaneite, and superparamagnetic (small particle) goethite and hematite. It is also possible for ferric iron to be associated to some unknown extent with igneous phases like pyroxene. We report here an electron microprobe (EMPA) and Moessbauer (MB) study of density separates of MIL 03346. The same separates were used for isotopic studies by [5]. Experimental techniques are described by [6,7].
NASA Astrophysics Data System (ADS)
López Días, Veneranda; Quang Hoang, Hung; Martínez-Carreras, Núria; Barnich, François; Wirtz, Tom; Pfister, Laurent; McDonnell, Jeffrey
2016-04-01
Hydrological studies relying on stable water isotopes to better understand water sources, flowpaths and transit times are currently limited by the coarse temporal resolution of sampling and analysis protocols. At present, two kinds of lab-based instruments are used : (i) the standard isotope ratio mass spectrometers (IRMS) [1] and (ii) the laser-based instruments [2, 3]. In both cases, samples need to be collected in the field and then transferred to the laboratory for the water isotopic ratio measurements (even further complex sample preparation is required for the IRMS). Hence, past and ongoing research targets the development of field deployable instruments for measuring stable water isotopes at high temporal frequencies. While recent studies have demonstrated that laser-based instruments may be taken to the field [4, 5], their size and power consumption still restrict their use to sites equipped with mains power or generators. Here, we present progress on the development of a field portable mass spectrometer (FieldSpec) for direct high frequency measurements of δ2H and δ18O ratios in water. The FieldSpec instrument is based upon the use of a double focusing magnetic sector mass spectrometer in combination with an electron impact ion source and a membrane dual inlet system. The instrument directly collects liquid water samples in the field, which are then converted into water vapour before being injected into the mass spectrometer for the stable isotope analysis. δ2H and δ18O are derived from the measured mass spectra. All the components are arranged in a vacuum case having a suit case type dimension with portable electronics and battery. Proof-of-concept experiments have been carried out to characterize the instrument. The results show that the FieldSpec instrument has good linearity (R2 = 0.99). The reproducibility of the instrument ranges between 1 and 4 ‰ for δ2H and between 0.1 and 0.4 ‰ for δ18O isotopic ratio measurements. A measurement frequency of less than 60 minutes per sample has been achieved. We intend to further increase the measurement frequency in the near future. In this presentation, we will describe the instrument, present experimental data reflecting its performance and discuss applications. [1] de Groot, P.A., 2004. Handbook of Stable Isotope Analytical Techniques, Vol.1. Elsevier, Amsterdam, 1234 pp [2] Lis, G., Wassenaar, L.I., Hendry, M.J., 2008. Analytical Chemistry 80 (1), 287-293. [3] Brand, W.A., Geilmann, H., Crosson, E.R., Rella, C.W., 2009. Rapid Communications in Mass Spectrometry 23, 1879-1884. [4] Berman, E.S.F., Gupta, M., Gabrielli, C., Garland, T., McDonnell, J.J., 2009. Water Resources Research 45 W1020, 1-7. [5] Munksgaard, N.C., Wurster, C.M., Bird, M.I., 2011. Rapid Communication Mass Spectrometry 25, 3706-3712.
NASA Astrophysics Data System (ADS)
Khorunzhev, G. A.; Burenin, R. A.; Meshcheryakov, A. V.; Sazonov, S. Yu.
2016-05-01
We have compiled a catalog of 903 candidates for type 1 quasars at redshifts 3 < z < 5.5 selected among the X-ray sources of the "serendipitous" XMM-Newton survey presented in the 3XMMDR4 catalog (the median X-ray flux is ≈5 × 10-15 erg s-1 cm-2 in the 0.5-2 keV energy band) and located at high Galactic latitudes | b| > 20° in Sloan Digital Sky Survey (SDSS) fields with a total area of about 300 deg2. Photometric SDSS data as well infrared 2MASS and WISE data were used to select the objects. We selected the point sources from the photometric SDSS catalog with a magnitude error δ mz' < 0.2 and a color i' - z' < 0.6 (to first eliminate the M-type stars). For the selected sources, we have calculated the dependences χ2( z) for various spectral templates from the library that we compiled for these purposes using the EAZY software. Based on these data, we have rejected the objects whose spectral energy distributions are better described by the templates of stars at z = 0 and obtained a sample of quasars with photometric redshift estimates 2.75 < z phot < 5.5. The selection completeness of known quasars at z spec > 3 in the investigated fields is shown to be about 80%. The normalized median absolute deviation (Δ z = | z spec - z phot|) is σ Δ z /(1+ z spec) = 0.07, while the outlier fraction is η = 9% when Δ z/(1 + z cпek.) > 0.2. The number of objects per unit area in our sample exceeds the number of quasars in the spectroscopic SDSS sample at the same redshifts approximately by a factor of 1.5. The subsequent spectroscopic testing of the redshifts of our selected candidates for quasars at 3 < z < 5.5 will allow the purity of this sample to be estimated more accurately.
CCSDS SOIS Subnetwork Services: A First Reference Implementation
NASA Astrophysics Data System (ADS)
Gunes-Lasnet, S.; Notebaert, O.; Farges, P.-Y.; Fowell, S.
2008-08-01
The CCSDS SOIS working groups are developing a range of standards for spacecraft onboard interfaces with the intention of promoting reuse of hardware and software designs across a range of missions while enabling interoperability of onboard systems from diverse sources. The CCSDS SOIS working groups released in June 2007 their red books for both Subnetwork and application support layers. In order to allow the verification of these recommended standards and to pave the way for future implementation onboard spacecrafts, it is essential for these standards to be prototyped on a representative spacecraft platform, to provide valuable feed back to the SOIS working group. A first reference implementation of both Subnetwork and Application Support SOIS services over SpaceWire and Mil-Std-1553 bus is thus being realised by SciSys Ltd and Astrium under an ESA contract.
Huo, Shu-Hui; An, Hai-Yan; Yu, Jing; Mao, Xue-Feng; Zhang, Zhe; Bai, Lei; Huang, Yan-Feng; Zhou, Peng-Xin
2017-09-29
In this study, we report a facile, environmental friendly fabrication of a type of magnetic metal-organic framework (MOF) MIL-100 that can be used for magnetic solid-phase extraction (MSPE). The magnetic MOF composites were fabricated using in situ calcination method. The as-synthesized materials exhibited both high porosity and magnetic characteristics. They used for the MSPE of polycyclic aromatic hydrocarbons (PAHs) from water samples. Such MOF-based magnetic solid-phase extraction in combination with gas chromatography equipped with a flame ionization detector (GC-FID), exhibited wide linearity (0.02-250μgL -1 ), low detection limits (4.6-8.9ngL -1 ), and high enrichment factors (452-907) for PAHs. The relative standard deviations (RSDs) for intra- and inter-day extractions of PAHs were ranging from 1.7% to 9.8% and 3.8% to 9.2%, respectively. The recoveries for spiked PAHs (1μgL -1 ) in water samples were in the range of 88.5% to 106.6%. The results showed that the special anion-π orbital (electron donor-acceptor) interaction and π-π stacking between magnetic MIL-100 and PAHs play an important role in the adsorption of PAHs. Copyright © 2017. Published by Elsevier B.V.
Standard Materials. A Descriptive List with Prices.
1962-03-12
steels (spec- 3.2.4. Freezing-point standards ------- 9 troscopic standards) ---------------- 24 3.2.5. Thermometric standards ------- 9 Ingot irons...metallo-organic materials soluble in lubri- the material is intended) wvith every other sample eating oils, thermometric cells, magnesium-treated...6.00 43g Zinc --------------------------------- 419.50 C ----------------------------- 350 6.00 3.2.5. Thermometric Cells These cells are primarily
USDA-ARS?s Scientific Manuscript database
Simultaneous chemical and sensory analysis based on gas chromatography-mass spectrometry-olfactometry (GC-MS-O) of air samples from livestock operations is a very useful approach for quantification of target odorous gases and also for ranking of odorous compounds. This information can help link spec...
Natural abundances of carbon isotopes in acetate from a coastal marine sediment
NASA Technical Reports Server (NTRS)
Blair, N. E.; Martens, C. S.; Des Marais, D. J.
1987-01-01
Measurements of the natural abundances of carbon isotopes were made in acetate samples isolated from the anoxic marine sediment of Cape Lookout Bight, North Carolina. The typical value of the total acetate carbon isotope ratio (delta 13C) was -16.1 +/- 0.2 per mil. The methyl and carboxyl groups were determined to be -26.4 +/- 0.3 and -6.0 +/- 0.3 per mil, respectively, for one sample. The isotopic composition of the acetate is thought to have resulted from isotopic discriminations that occurred during the cycling of that molecule. Measurements of this type, which have not been made previously in the natural environment, may provide information about the dominant microbial pathways in anoxic sediments as well as the processes that influence the carbon isotopic composition of biogenic methane from many sources.
NASA Astrophysics Data System (ADS)
Nelson, David; McManus, Barry; Shorter, Joanne; Zahniser, Mark; Ono, Shuhei
2014-05-01
The capacity for real time precise in situ measurements of isotopic ratios of a variety of trace gases at ambient concentrations continues to create new opportunities for the study of the exchanges and fluxes of gases in the environment. Aerodyne Research has made rapid progress in laser based instruments since our introduction in 2007 of the first truly field worthy instrument for real time measurements of isotopologues of carbon dioxide. We have focused on two instrument design platforms, with either one or two lasers. Absorption cells with more than 200 meters path length allow precise measurements of trace gases with low ambient concentrations. Most of our systems employ mid infrared quantum cascade lasers. However, recently available 3 micron antimonide based diode lasers are also proving useful for isotopic measurements. By substituting different lasers and detectors, we can simultaneously measure the isotopic composition of a variety of gases, including: H2O, CO2, CH4, N2O and CO. Our newest instrument for true simultaneous measurement of isotopologues of CO2 (12CO2, 13CO2, 12C18O16O) has (1 s) precision better than 0.1 per mil for both ratios. The availability of 10 Hz measurements allows measurement of isotopic fluxes via eddy correlation. The single laser instrument fits in a 19 inch rack and is only 25 cm tall. A two laser instrument is larger, but with that instrument we can also measure clumped isotopes of CO2, with 1 second precisions of: 2.3 per mil for 13C18O16O, and 6.7 per mil for 13C17O16O. The sample size for such a measurement corresponds to 0.2 micromole of pure CO2. Another variation on the two laser instrument simultaneously measures isotopologues of CO2 (12CO2, 13CO2, 12C18O16O) and H2O (H216O, H218O, HD16O). Preliminary results for water ratio precisions (in 1s) are 0.1 per mil for H218O and 0.3 per mil for HD16O, simultaneous (1 s) precisions for isotopologues of CO2 of ~0.1 per mil. Methane, nitrous oxide and carbon monoxide have such low ambient concentrations that real-time isotopologue measurements are a serious challenge. For these gases, we typically use our 200 m absorption cell. Several of these instruments have already been used for long term field measurements of isotopologues of methane, (12CH4, 13CH4), with a demonstrated (1 s) precision of 1.5 per mil. A new version of this instrument operating near 3.3 microns has recently been developed to quantify 13CH4 and CH3D simultaneously. In separate experiments at MIT, using trapped concentrated samples, we have made highly precise measurements of the abundance of the clumped isotope of methane: 13CH3D. We are also developing methods to monitor the isotopic abundance of the isotopes of CO and N2O. We have achieved a measurement precision for ambient 13CO (1 s) of 1.9 per mil. For the isotopologues of N2O (14N216O, 14N15N 16O, 15N14N 16O, 14N218O), we have demonstrated (1 s) precision at ambient levels (320 ppb) of ~3 per mil. For N2O, a quasi continuous preconcentrator has been used to give even better precisions (<0.1 per mil) and one is being developed for CO.
Liu, Dandan; Liu, Yunqi; Dai, Fangna; Zhao, Jinchong; Yang, Kang; Liu, Chenguang
2015-10-07
In this paper, an efficient method to fabricate Al-based metal organic framework (Al-MOF) MIL-96 crystals with controllable size and morphology, by mixing other forms of reactants to replace the coordination modulators or capping agents, is presented. The size and morphology of the MIL-96 crystals can be selectively varied by simply altering the ratio of dual reactants via their hydrolysis reaction. All the samples were characterized by X-ray powder diffraction (XRD), scanning electron microscopy (SEM), Fourier Transform Infrared (FT-IR) spectroscopy, thermogravimetric analysis (TGA) and nitrogen sorption. Then based on the BFDH theory, a mechanism for the impact of hydrolysis of reactants on the crystal size and morphology is presented and discussed. We also evaluated the performance of these MOFs as sorbents for capturing CO2, and they all show enhanced adsorption properties compared with the bulk material, displaying high adsorption capacities on CO2 at atmospheric pressure and ambient temperature.
Roszkowska, Milena; Stec, Daniel; Ciobanu, Daniel Adrian; Kaczmarek, Łukasz
2016-04-21
In 31 samples of mosses and lichens collected in the Argentinean province of Río Negro, 657 tardigrades, 53 exuviae and 219 free-laid eggs were found. In total, 20 species were identified: Diphascon chilenense, Dip. mitrense, Echiniscus bigranulatus, Ech. corrugicaudatus, Ech. merokensis merokensis, Ech. testudo, Hebesuncus mollispinus, Hypsibius convergens, Macrobiotus cf. anderssoni, Mac. andinus, Mac. kazmierskii, Mac. patagonicus, Mesobiotus szeptyckii, Mes. pseudoblocki sp. nov., Milnesium argentinum, Mil. beatae, Mil. brachyungue, Mil. granulatum, Mopsechiniscus granulosus, Minibiotus pseudostellarus sp. nov. Of the two new species, Mesobiotus pseudoblocki sp. nov. is most similar to Mes. blocki, but it differs mainly by the lack of dentate lunules, smaller eggs and presence of reticular design on egg processes. Minibiotus pseudostellarus sp. nov. is most similar to Min. constellatus, Min. eichhorni, Min. sidereus or Min. vinciguerrae, but it differs from them by the presence of 'pseudo-star'-shaped pores in the dorsal cuticle instead of fully developed 'stars' and by other morphometric characters.
Precision Cleaning of Oxygen Systems and Components
NASA Technical Reports Server (NTRS)
McLaughlin, Russell
2009-01-01
Currently, NASA uses Dichloropentafluoropropane (HCFC-225), a Class II ozone depleting substance (ODs), to clean contaminated oxygen systems. Starting in 20 15, the Montreal Protocols and Clean Air Act prohibit the production and importation of all hydrochlorofluorocarbons (HCFC), except for limited use in refrigeration applications. Thus, a new non-ozone depleting solvent needs to be developed for use in cleaning. Optimally, such a solvent should also be environmentally benign or green to avoid needing to replace the new solvent with yet another solvent in the future due to other environmental concerns. Work for the first year consisted of two parts. The first part was developing a method of testing the cleaning efficiency of potential solvents. Stainless steel coupons were contaminated with a known weight of various contaminants and contaminant combinations and then immersed in solvent for ten minutes. The coupons were then removed and dried in an oven until all solvent had evaporated. Once dry, the coupons were weighed and the mass of the non-volatile residue (NVR) left on the coupon was determined. The cleaning efficiency of the solvents is reported as percent cleaning, with 100% cleaning being zero NVR left on the test coupon. The second half of the first goal was to use the develop method to perform baseline testing on current solvents. The second part of the work was to begin exploring alternative cleaning solvents. A variety of hydrofluorocarbons (HFCs) were tested. Preliminary testing was also performed with ionic liquids and aqueous surfactant solutions. Once potential solvents were identified, an analysis of the performance and environmental characteristics of each was to be conducted. Four contaminants were specified for use in testing. These are Mil-Spec-H-5606 (5606), a hydraulic fluid, Mil-H-83282B (83282), another hydraulic fluid, diethylhexyl sebacate (Sebacate), and WD-40. The structures of these contaminants are all similar, with long aliphatic hydrocarbon chains of lengths between fifteen and fifty. Contaminants were tested both individually and in combination. All combinations were done with equal weights of the constituent contaminants.
Catastrophic photometric redshift errors: Weak-lensing survey requirements
Bernstein, Gary; Huterer, Dragan
2010-01-11
We study the sensitivity of weak lensing surveys to the effects of catastrophic redshift errors - cases where the true redshift is misestimated by a significant amount. To compute the biases in cosmological parameters, we adopt an efficient linearized analysis where the redshift errors are directly related to shifts in the weak lensing convergence power spectra. We estimate the number N spec of unbiased spectroscopic redshifts needed to determine the catastrophic error rate well enough that biases in cosmological parameters are below statistical errors of weak lensing tomography. While the straightforward estimate of N spec is ~10 6 we findmore » that using only the photometric redshifts with z ≤ 2.5 leads to a drastic reduction in N spec to ~ 30,000 while negligibly increasing statistical errors in dark energy parameters. Therefore, the size of spectroscopic survey needed to control catastrophic errors is similar to that previously deemed necessary to constrain the core of the z s – z p distribution. We also study the efficacy of the recent proposal to measure redshift errors by cross-correlation between the photo-z and spectroscopic samples. We find that this method requires ~ 10% a priori knowledge of the bias and stochasticity of the outlier population, and is also easily confounded by lensing magnification bias. In conclusion, the cross-correlation method is therefore unlikely to supplant the need for a complete spectroscopic redshift survey of the source population.« less
Gu, Zhi-Yuan; Yang, Cheng-Xiong; Chang, Na; Yan, Xiu-Ping
2012-05-15
In modern analytical chemistry researchers pursue novel materials to meet analytical challenges such as improvements in sensitivity, selectivity, and detection limit. Metal-organic frameworks (MOFs) are an emerging class of microporous materials, and their unusual properties such as high surface area, good thermal stability, uniform structured nanoscale cavities, and the availability of in-pore functionality and outer-surface modification are attractive for diverse analytical applications. This Account summarizes our research on the analytical applications of MOFs ranging from sampling to chromatographic separation. MOFs have been either directly used or engineered to meet the demands of various analytical applications. Bulk MOFs with microsized crystals are convenient sorbents for direct application to in-field sampling and solid-phase extraction. Quartz tubes packed with MOF-5 have shown excellent stability, adsorption efficiency, and reproducibility for in-field sampling and trapping of atmospheric formaldehyde. The 2D copper(II) isonicotinate packed microcolumn has demonstrated large enhancement factors and good shape- and size-selectivity when applied to on-line solid-phase extraction of polycyclic aromatic hydrocarbons in water samples. We have explored the molecular sieving effect of MOFs for the efficient enrichment of peptides with simultaneous exclusion of proteins from biological fluids. These results show promise for the future of MOFs in peptidomics research. Moreover, nanosized MOFs and engineered thin films of MOFs are promising materials as novel coatings for solid-phase microextraction. We have developed an in situ hydrothermal growth approach to fabricate thin films of MOF-199 on etched stainless steel wire for solid-phase microextraction of volatile benzene homologues with large enhancement factors and wide linearity. Their high thermal stability and easy-to-engineer nanocrystals make MOFs attractive as new stationary phases to fabricate MOF-coated capillaries for high-resolution gas chromatography (GC). We have explored a dynamic coating approach to fabricate a MOF-coated capillary for the GC separation of important raw chemicals and persistent organic pollutants with high resolution and excellent selectivity. We have combined a MOF-coated fiber for solid-phase microextraction with a MOF-coated capillary for GC separation, which provides an effective MOF-based tandem molecular sieve platform for selective microextraction and high-resolution GC separation of target analytes in complex samples. Microsized MOFs with good solvent stability are attractive stationary phases for high-performance liquid chromatography (HPLC). These materials have shown high resolution and good selectivity and reproducibility in both the normal-phase HPLC separation of fullerenes and substituted aromatics on MIL-101 packed columns and position isomers on a MIL-53(Al) packed column and the reversed-phase HPLC separation of a wide range of analytes from nonpolar to polar and acidic to basic solutes. Despite the above achievements, further exploration of MOFs in analytical chemistry is needed. Especially, analytical application-oriented engineering of MOFs is imperative for specific applications.
Bromberg, Lev; Hatton, T Alan
2011-12-01
Porous materials based on chromium(III) terephthalate metal organic frameworks (MIL-101) and their composites with phosphotungstic acid (PTA) were studied as heterogeneous acid catalysts in aldehyde-alcohol reactions exemplified by acetaldehyde-phenol (A-P) condensation and dimethylacetal formation from benzaldehyde and methanol (B-M reaction). The MIL-101 was synthesized solvothermically in water, and the MIL101/PTA composite materials were obtained by either impregnation of the already prepared MIL-101 porous matrix with phosphotungstic acid solution or by solvothermic treatment of aqueous mixtures of Cr(NO(3))(3), and terephthalic and phosphotungstic acids. The MIL101/PTA materials appeared to be effective catalysts for both A-P and B-M reactions occurring at room temperature, with half-lives ranging from 0.5 h (A-P) to 1.5-2 h (B-M) and turnover numbers over 600 for A-P and over 2900 for the B-M reaction, respectively. A synergistic effect of the strong acidic moieties (PTA) addition to mildly acidic Brønsted and Lewis acid cites of the MIL-101 was observed with the MIL101/PTA composites. The ability of the PTA and MIL101/PTA materials to strongly absorb and condense acetaldehyde vapors was discovered, with the MIL101/PTA absorbing over 10-fold its dry weight of acetaldehyde condensate at room temperature. The acetaldehyde was converted rapidly to crotonaldehyde and higher-molecular-weight compounds while in contact with MIL-101 and MIL101/PTA materials. The stability of the MIL-101 and MIL101/PTA catalysts was assessed within four cycles of the 1-day alcohol-aldehyde reactions in terms of the overall catalyst recovery, PTA or Cr content, and reaction rate constants in each cycle. The loss of the catalyst over 4 cycles was approximately 10 wt % for all tested catalysts due to the incomplete recovery and minute dissolution of the components. The reaction rates in all cycles remained unchanged and the catalyst losses stopped after the third cycle. The developed MIL101/PTA composites appear to be feasible for industrial catalytic applications. © 2011 American Chemical Society
Aldrighetti, Luca; Ratti, Francesca; Cillo, Umberto; Ferrero, Alessandro; Ettorre, Giuseppe Maria; Guglielmi, Alfredo; Giuliante, Felice; Calise, Fulvio
2017-09-01
The Italian Group of MILS (I Go MILS) prospective registry was established in 2014 with the goals to create a hub for data and projects on a national basis and to promote the diffusion and implementation of MILS programs on a national scale. The primary endpoint of the present study is to give a snapshot of the real diffusion and outcomes of MILS in Italy, while analyzing the role of the registry in the implementation of MILS programs nationwide. The I Go MILS Registry is a prospective and intention-to-treat registry opened to any Italian center performing MILS, without restriction criteria based on number of procedures. The Registry is developed through the eClinical, an electronic platform for the management of clinical trials and is based on 34 clinical variables, regarding indication, intra- and postoperative course. Clinical outcomes and data regarding implementation of MILS activity have been analyzed for the aim of the study. Between November 2014 and June 2017, data from 1678 MILS performed in 48 centers have been collected (mean number of procedures per center 35, range 1-302). 22% of procedures were performed for benign and 78% for malignant disease (HCC constituted the 49.1% and CRLM the 31.2% of malignant tumors). Major liver resections (>3 liver segments), including right and left hepatectomies, trisectionectomies and ALPPS procedures were 10% of the series. Mean blood loss was 200 ± 230 mL Morbidity rate was 20.5% and mortality was 0.3%. 10.4% of cases were converted to open approach. Median length of stay was 5 days. MILS/total resections ratio in 13 experienced centers increased from 14 to 30% after Registry establishment. MILS programs are well established in Italy, with progressive increase both in the number of cases and in the numerosity of centers. The I Go MILS Registry is playing a crucial role in monitoring the development of MILS in the real world on a national basis while giving a significant contribution to the implementation of MILS programs.
Ashley, Elizabeth A; Touabi, Malek; Ahrer, Margareta; Hutagalung, Robert; Htun, Khayae; Luchavez, Jennifer; Dureza, Christine; Proux, Stephane; Leimanis, Mara; Lwin, Myo Min; Koscalova, Alena; Comte, Eric; Hamade, Prudence; Page, Anne-Laure; Nosten, François; Guerin, Philippe J
2009-01-01
Background In areas where non-falciparum malaria is common rapid diagnostic tests (RDTs) capable of distinguishing malaria species reliably are needed. Such tests are often based on the detection of parasite lactate dehydrogenase (pLDH). Methods In Dawei, southern Myanmar, three pLDH based RDTs (CareStart™ Malaria pLDH (Pan), CareStart™ Malaria pLDH (Pan, Pf) and OptiMAL-IT®)were evaluated in patients presenting with clinically suspected malaria. Each RDT was read independently by two readers. A subset of patients with microscopically confirmed malaria had their RDTs repeated on days 2, 7 and then weekly until negative. At the end of the study, samples of study batches were sent for heat stability testing. Results Between August and November 2007, 1004 patients aged between 1 and 93 years were enrolled in the study. Slide microscopy (the reference standard) diagnosed 213 Plasmodium vivax (Pv) monoinfections, 98 Plasmodium falciparum (Pf) mono-infections and no malaria in 650 cases. The sensitivities (sens) and specificities (spec), of the RDTs for the detection of malaria were- CareStart Malaria™ pLDH (Pan) test: sens 89.1% [CI95 84.2-92.6], spec 97.6% [CI95 96.5-98.4] OptiMal-IT®: Pf+/- other species detection: sens 95.2% [CI95 87.5-98.2], spec 94.7% [CI95 93.3-95.8]; non-Pf detection alone: sens 89.6% [CI95 83.6-93.6], spec 96.5% [CI95 94.8-97.7] CareStart Malaria™ pLDH (Pan, Pf): Pf+/- other species: sens 93.5% [CI9585.4-97.3], spec 97.4% [95.9-98.3]; non-Pf: sens 78.5% [CI9571.1-84.4], spec 97.8% [CI95 96.3-98.7] Inter-observer agreement was excellent for all tests (kappa > 0.9). The median time for the RDTs to become negative was two days for the CareStart™ Malaria tests and seven days for OptiMAL-IT®. Tests were heat stable up to 90 days except for OptiMAL-IT® (Pf specific pLDH stable to day 20 at 35°C). Conclusion None of the pLDH-based RDTs evaluated was able to detect non-falciparum malaria with high sensitivity, particularly at low parasitaemias. OptiMAL-IT® performed best overall and would perform best in an area of high malaria prevalence among screened fever cases. However, heat stability was unacceptable and the number of steps to perform this test is a significant drawback in the field. A reliable, heat-stable, highly sensitive RDT, capable of diagnosing all Plasmodium species has yet to be identified. PMID:19860920
Ashley, Elizabeth A; Touabi, Malek; Ahrer, Margareta; Hutagalung, Robert; Htun, Khayae; Luchavez, Jennifer; Dureza, Christine; Proux, Stephane; Leimanis, Mara; Lwin, Myo Min; Koscalova, Alena; Comte, Eric; Hamade, Prudence; Page, Anne-Laure; Nosten, François; Guerin, Philippe J
2009-10-27
In areas where non-falciparum malaria is common rapid diagnostic tests (RDTs) capable of distinguishing malaria species reliably are needed. Such tests are often based on the detection of parasite lactate dehydrogenase (pLDH). In Dawei, southern Myanmar, three pLDH based RDTs (CareStart Malaria pLDH (Pan), CareStart Malaria pLDH (Pan, Pf) and OptiMAL-IT)were evaluated in patients presenting with clinically suspected malaria. Each RDT was read independently by two readers. A subset of patients with microscopically confirmed malaria had their RDTs repeated on days 2, 7 and then weekly until negative. At the end of the study, samples of study batches were sent for heat stability testing. Between August and November 2007, 1004 patients aged between 1 and 93 years were enrolled in the study. Slide microscopy (the reference standard) diagnosed 213 Plasmodium vivax (Pv) monoinfections, 98 Plasmodium falciparum (Pf) mono-infections and no malaria in 650 cases. The sensitivities (sens) and specificities (spec), of the RDTs for the detection of malaria were- CareStart Malaria pLDH (Pan) test: sens 89.1% [CI95 84.2-92.6], spec 97.6% [CI95 96.5-98.4]. OptiMal-IT: Pf+/- other species detection: sens 95.2% [CI95 87.5-98.2], spec 94.7% [CI95 93.3-95.8]; non-Pf detection alone: sens 89.6% [CI95 83.6-93.6], spec 96.5% [CI95 94.8-97.7]. CareStart Malaria pLDH (Pan, Pf): Pf+/- other species: sens 93.5% [CI95 85.4-97.3], spec 97.4% [95.9-98.3]; non-Pf: sens 78.5% [CI95 71.1-84.4], spec 97.8% [CI95 96.3-98.7]. Inter-observer agreement was excellent for all tests (kappa > 0.9). The median time for the RDTs to become negative was two days for the CareStart Malaria tests and seven days for OptiMAL-IT. Tests were heat stable up to 90 days except for OptiMAL-IT (Pf specific pLDH stable to day 20 at 35 degrees C). None of the pLDH-based RDTs evaluated was able to detect non-falciparum malaria with high sensitivity, particularly at low parasitaemias. OptiMAL-IT performed best overall and would perform best in an area of high malaria prevalence among screened fever cases. However, heat stability was unacceptable and the number of steps to perform this test is a significant drawback in the field. A reliable, heat-stable, highly sensitive RDT, capable of diagnosing all Plasmodium species has yet to be identified.
Tomascak, P.B.; Tera, F.; Helz, R.T.; Walker, R.J.
1999-01-01
We report measurements of the isotopic composition of lithium in basalts using a multicollector magnetic sector plasma-source mass spectrometer (MC-ICP-MS). This is the first application of this analytical technique to Li isotope determination. External precision of multiple replicate and duplicate measurements for a variety of sample types averages ??1.1??? (2?? population). The method allows for the rapid (???8 min/sample) analysis of small samples (???40 ng Li) relative to commonly used thermal ionization methods. The technique has been applied to a suite of samples from Kilauea Iki lava lake, Hawaii. The samples range from olivine-rich cumulitic lava to SiO2 - and K2O-enriched differentiated liquids, and have ??7Li (per mil deviation of sample 7Li/6Li relative to the L-SVEC standard) of +3.0 to +4.8. The data indicate a lack of per mil-level Li isotope fractionation as a result of crystal-liquid fractionation at temperatures greater than 1050??C. This conclusion has been tacitly assumed but never demonstrated, and is important to the interpretation of Li isotope results from such geochemically complex environments as island arcs. Copyright ?? 1999 Elsevier Science Ltd.
Ivins, Brian J; Lange, Rael T; Cole, Wesley R; Kane, Robert; Schwab, Karen A; Iverson, Grant L
2015-02-01
Base rates of low ANAM4 TBI-MIL scores were calculated in a convenience sample of 733 healthy male active duty soldiers using available military reference values for the following cutoffs: ≤2nd percentile (2 SDs), ≤5th percentile, <10th percentile, and <16th percentile (1 SD). Rates of low scores were also calculated in 56 active duty male soldiers who sustained an mTBI an average of 23 days (SD = 36.1) prior. 22.0% of the healthy sample and 51.8% of the mTBI sample had two or more scores below 1 SD (i.e., 16th percentile). 18.8% of the healthy sample and 44.6% of the mTBI sample had one or more scores ≤5th percentile. Rates of low scores in the healthy sample were influenced by cutoffs and race/ethnicity. Importantly, some healthy soldiers obtain at least one low score on ANAM4. These base rate analyses can improve the methodology for interpreting ANAM4 performance in clinical practice and research. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Gupta, Krishna M.; Zhang, Kang; Jiang, Jianwen
2015-01-01
A molecular simulation study is reported on glucose recovery from aqueous solutions by adsorption in metal-organic framework MIL-101. The F atom of MIL-101 is identified to be the most favorable adsorption site. Among three MIL-101-X (X = H, NH2 or CH3), the parent MIL-101 exhibits the highest adsorption capacity and recovery efficacy. Upon functionalization by -NH2 or -CH3 group, the steric hindrance in MIL-101 increases; consequently, the interactions between glucose and framework become less attractive, thus reducing the capacity and mobility of glucose. The presence of ionic liquid, 1-ethyl-3-methyl-imidazolium acetate, as an impurity reduces the strength of hydrogen-bonding between glucose and MIL-101, and leads to lower capacity and mobility. Upon adding anti-solvent (ethanol or acetone), a similar adverse effect is observed. The simulation study provides useful structural and dynamic properties of glucose in MIL-101, and it suggests that MIL-101 might be a potential candidate for glucose recovery. PMID:26242874
NASA Astrophysics Data System (ADS)
Gupta, Krishna M.; Zhang, Kang; Jiang, Jianwen
2015-08-01
A molecular simulation study is reported on glucose recovery from aqueous solutions by adsorption in metal-organic framework MIL-101. The F atom of MIL-101 is identified to be the most favorable adsorption site. Among three MIL-101-X (X = H, NH2 or CH3), the parent MIL-101 exhibits the highest adsorption capacity and recovery efficacy. Upon functionalization by -NH2 or -CH3 group, the steric hindrance in MIL-101 increases; consequently, the interactions between glucose and framework become less attractive, thus reducing the capacity and mobility of glucose. The presence of ionic liquid, 1-ethyl-3-methyl-imidazolium acetate, as an impurity reduces the strength of hydrogen-bonding between glucose and MIL-101, and leads to lower capacity and mobility. Upon adding anti-solvent (ethanol or acetone), a similar adverse effect is observed. The simulation study provides useful structural and dynamic properties of glucose in MIL-101, and it suggests that MIL-101 might be a potential candidate for glucose recovery.
SuperSpec, The On-Chip Spectrometer: Improved NEP and Antenna Performance
NASA Astrophysics Data System (ADS)
Wheeler, Jordan; Hailey-Dunsheath, S.; Shirokoff, E.; Barry, P. S.; Bradford, C. M.; Chapman, S.; Che, G.; Doyle, S.; Glenn, J.; Gordon, S.; Hollister, M.; Kovács, A.; LeDuc, H. G.; Mauskopf, P.; McGeehan, R.; McKenney, C.; Reck, T.; Redford, J.; Ross, C.; Shiu, C.; Tucker, C.; Turner, J.; Walker, S.; Zmuidzinas, J.
2018-05-01
SuperSpec is a new technology for mm and sub-mm spectroscopy. It is an on-chip spectrometer being developed for multi-object, moderate-resolution (R˜ 300 ), large bandwidth survey spectroscopy of high-redshift galaxies for the 1 mm atmospheric window. This band accesses the CO ladder in the redshift range of z = 0-4 and the [CII] 158 μm line from redshift z = 5-9. SuperSpec employs a novel architecture in which detectors are coupled to a series of resonant filters along a single microwave feedline instead of using dispersive optics. This construction allows for the creation of a full spectrometer occupying only ˜ 10 cm^2 of silicon, a reduction in size of several orders of magnitude when compared to standard grating spectrometers. This small profile enables the production of future multi-beam spectroscopic instruments envisioned for the millimeter band to measure the redshifts of dusty galaxies efficiently. The SuperSpec collaboration is currently pushing toward the deployment of a SuperSpec demonstration instrument in fall of 2018. The progress with the latest SuperSpec prototype devices is presented; reporting increased responsivity via a reduced inductor volume (2.6 μm^3 ) and the incorporation of a new broadband antenna. A detector NEP of 3-4 × 10^{-18} W/Hz^{0.5} is obtained, sufficient for background-limited observation on mountaintop sites. In addition, beam maps and efficiency measurements of a new wide-band dual bow-tie slot antenna are shown.
NASA Astrophysics Data System (ADS)
Fourqurean, J. W.; Fourqurean, J. W.; Anderson, W. T.; Anderson, W. T.
2001-12-01
The shallow marine waters surrounding the southern tip of Florida provide an ideal environment for seagrasses, which are the most common benthic community in the region. Yet, these communities are susceptible to a variety of anthropogenic disturbances, especially changes in water quality caused by an increase the nutrient flux to the near shore environment. In order to better understand the carbon and nitrogen isotopic ratio in marine plants, an extensive times series analysis was constructed from quarterly sampling of Thalassia testudinum (the dominate species in the study area) from 1996 through 1998. Sites for study where selected from permanent stations within the Florida Keys National Marine Sanctuary (FKNMS), from both sides of the Florida Keys - two stations on the bay side and two stations on the reef side. These data will also help to constrain elements of the carbon and nitrogen cycles affecting this region. The data analyzed over the three year study period show unique cyclic trends associated with seasonal changes in primary productivity and potentially changes in the nitrogen and carbon pools. Additionally, the analysis of our time series indicates that isotope food web studies need to take into account spatial and temporal changes when evaluating trophic levels. The mean carbon and nitrogen isotope values of T. testudinum from all 4 stations vary respectively from -7.2 per mil to -10.41 and 1.1 per mil to 2.2 per mil (n = 48). However, certain stations displayed anonymously depleted nitrogen isotope values, values as low as -1.2 per mil. These values potentially indicated that biogeochmical processes like N fixation, ammonification and denitrification cause regional pattern in the isotopic composition of the source DIN. Both carbon and nitrogen isotopes displayed seasonal enrichment-depletion trends, with maximum enrichment occurring during the summer. The overall seasonal variation for carbon 13 from the different stations ranged from 1 per mil to greater than 3 per mil; whereas seasonal variations in d15N between different stations ranged from about 1 per mil to greater than 5 per mil. Additionally certain sites showed a positive isotope values and productivity. These data indicate a high degree of seasonal variability due to changes in productivity, environmental parameters, and oceanographic controls. The more open settings are not restricted by the temperature changes occurring in the shallower water sites. Additionally, carbon and nitrogen sources can change due to the mineralization of OM from different sources from nearby mangrove islands and/or the Everglades to the north.
Studying Star and Planet Formation with the Submillimeter Probe of the Evolution of Cosmic Structure
NASA Technical Reports Server (NTRS)
Rinehart, Stephen A.
2005-01-01
The Submillimeter Probe of the Evolution of Cosmic Structure (SPECS) is a far- infrared/submillimeter (40-640 micrometers) spaceborne interferometry concept, studied through the NASA Vision Missions program. SPECS is envisioned as a 1-km baseline Michelson interferometer with two 4- meter collecting mirrors. To maximize science return, SPECS will have three operational modes: a photometric imaging mode, an intermediate spectral resolution mode (R approximately equal to 1000-3000), and a high spectral resolution mode (R approximately equal to 3 x 10(exp 5)). The first two of these modes will provide information on all sources within a 1 arcminute field-of-view (FOV), while the the third will include sources in a small (approximately equal to 5 arcsec) FOV. With this design, SPECS will have angular resolution comparable to the Hubble Space Telescope (50 mas) and sensitivity more than two orders of magnitude better than Spitzer (5sigma in 10ks of approximately equal to 3 x 10(exp 7) Jy Hz). We present here some of the results of the recently-completed Vision Mission Study for SPECS, and discuss the application of this mission to future studies of star and planet formation.
Second-generation Micro-Spec: a medium-resolution spectrometer-on-a-chip for submillimeter astronomy
NASA Astrophysics Data System (ADS)
Cataldo, Giuseppe; Barrentine, Emily M.; Bulcha, Berhanu T.; Ehsan, Negar; Hess, Larry A.; Noroozian, Omid; Stevenson, Thomas R.; U-Yen, Kongpop; Wollack, Edward; Moseley, Samuel Harvey
2018-01-01
This work reports on the design of a second-generation Micro-Spec (µ-Spec), a direct-detection spectrometer which integrates all the components of a diffraction-grating spectrometer onto a ~10-cm2 chip by means of superconducting microstrip transmission lines on a monocrystalline silicon substrate. The second-generation µ-Spec is designed to operate with a resolving power of 512 over the 500-1000 µm (300-600 GHz) wavelength range, a band of interest for several spectroscopic applications in astrophysics and the study of the early (z > 8) Universe. High-altitude balloon missions would provide the first testbed to demonstrate the µ-Spec technology in a space-like environment and would represent an economically viable venue for multiple observation campaigns.A brief overview of each instrument subsystem will be provided. Emphasis will be given to the design of the spectrometer’s two-dimensional diffractive region, through which the light of different wavelengths is focused on the kinetic inductance detectors along the focal plane. An optical design optimized for balloon missions through an optimization process that satisfies specific requirements on spectrometer’s size, operating spectral range and optical performance is presented in terms of geometric layout, spectral purity and efficiency.
Discrete event performance prediction of speculatively parallel temperature-accelerated dynamics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zamora, Richard James; Voter, Arthur F.; Perez, Danny
Due to its unrivaled ability to predict the dynamical evolution of interacting atoms, molecular dynamics (MD) is a widely used computational method in theoretical chemistry, physics, biology, and engineering. Despite its success, MD is only capable of modeling time scales within several orders of magnitude of thermal vibrations, leaving out many important phenomena that occur at slower rates. The Temperature Accelerated Dynamics (TAD) method overcomes this limitation by thermally accelerating the state-to-state evolution captured by MD. Due to the algorithmically complex nature of the serial TAD procedure, implementations have yet to improve performance by parallelizing the concurrent exploration of multiplemore » states. Here we utilize a discrete event-based application simulator to introduce and explore a new Speculatively Parallel TAD (SpecTAD) method. We investigate the SpecTAD algorithm, without a full-scale implementation, by constructing an application simulator proxy (SpecTADSim). Finally, following this method, we discover that a nontrivial relationship exists between the optimal SpecTAD parameter set and the number of CPU cores available at run-time. Furthermore, we find that a majority of the available SpecTAD boost can be achieved within an existing TAD application using relatively simple algorithm modifications.« less
Discrete event performance prediction of speculatively parallel temperature-accelerated dynamics
Zamora, Richard James; Voter, Arthur F.; Perez, Danny; ...
2016-12-01
Due to its unrivaled ability to predict the dynamical evolution of interacting atoms, molecular dynamics (MD) is a widely used computational method in theoretical chemistry, physics, biology, and engineering. Despite its success, MD is only capable of modeling time scales within several orders of magnitude of thermal vibrations, leaving out many important phenomena that occur at slower rates. The Temperature Accelerated Dynamics (TAD) method overcomes this limitation by thermally accelerating the state-to-state evolution captured by MD. Due to the algorithmically complex nature of the serial TAD procedure, implementations have yet to improve performance by parallelizing the concurrent exploration of multiplemore » states. Here we utilize a discrete event-based application simulator to introduce and explore a new Speculatively Parallel TAD (SpecTAD) method. We investigate the SpecTAD algorithm, without a full-scale implementation, by constructing an application simulator proxy (SpecTADSim). Finally, following this method, we discover that a nontrivial relationship exists between the optimal SpecTAD parameter set and the number of CPU cores available at run-time. Furthermore, we find that a majority of the available SpecTAD boost can be achieved within an existing TAD application using relatively simple algorithm modifications.« less
MISR Level 3 Radiance Versioning
Atmospheric Science Data Center
2016-11-04
... ESDT Product File Name Prefix Current Quality Designations MIL3DRD, MIL3MRD, MIL3QRD, and MIL3YRD ... Data Product Specification Rev K (PDF). Update to work with new format of the input PGE 1 files. F02_0007 ...
Harper, Jason
2018-03-02
Jason Harper, an electrical engineer in Argonne National Laboratory's EV-Smart Grid Interoperability Center, discusses his SpEC Module invention that will enable fast charging of electric vehicles in under 15 minutes. The module has been licensed to BTCPower.
NASA Technical Reports Server (NTRS)
Whitaker, A. F.; Little, S. A.; Wooden, V. A.
1980-01-01
Three types of high performance silicon solar cells, textured P(+)8 to 10 mil, planar P(+)8 to 10 mil and planar P(+)2 mil were evaluated for their low temperature and low intensity (LTLI) performance. Sixteen cells of each type were subjected to 11 temperatures and 9 intensities. The textured P(+)8 to 10 mil cells provided the best performance both at 1 astronomical unit and at LTLI conditions. The average efficiencies of this cell were 14.5 percent at 1 solar constant/+25 C and 18.7 percent at 0.086 solar constant/-100 C.
Wu, Jianfeng; Wang, Yu; Li, Jianqing; Song, Aiguo
2016-01-01
For suppressing the crosstalk problem due to wire resistances and contacted resistances of the long flexible cables in tactile sensing systems, we present a novel two-wire fast readout approach for the two-dimensional resistive sensor array in shared row-column fashion. In the approach, two wires are used for every driving electrode and every sampling electrode in the resistive sensor array. The approach with a high readout rate, though it requires a large number of wires and many sampling channels, solves the cable crosstalk problem. We also verified the approach’s performance with Multisim simulations and actual experiments. PMID:27213373
Temperature Sensing for Oil, Gas, and Structural Analysis
NASA Technical Reports Server (NTRS)
2006-01-01
In 1996, Systems and Processes Engineering Corporation (SPEC), of Austin, Texas, undertook a NASA Small Business Innovation Research (SBIR) contract with Langley Research Center to develop a compact and lightweight digital thermal sensing (DTS) system for monitoring the cryogenic tanks on the X-33 prototype aircraft. That technology, along with a processor developed by SPEC for Goddard Space Flight Center, was space-qualified and integrated into several NASA missions. SPEC formed an ancillary organization, SensorTran, Inc., to continue work developing the DTS technology for a variety of commercial and industrial applications.
NASA Astrophysics Data System (ADS)
Hegarty, Michael G.
2005-05-01
The U.S. Air Force is currently in the process of developing a revision to MIL-STD-1553 that will provide additional digital communication bandwidth beyond MIL-STD-1553B's 1 Megabit per second (Mbps) rate. The proposed revision to MIL-STD-1553 (referred to as MIL-STD-1553C) is targeting 200 Mbps as a baseline data rate. This paper explores the feasibility of the U.S. Air Force's proposed revision to MIL-STD-1553 based on studies conducted by Data Device Corporation (DDC). A combination of empirical and theoretical methods is used to determine if a MIL-STD-1553B network contains sufficient capacity to support the proposed 200 Mbps data rate. The results of DDC's analysis is that for some MIL-STD-1553 buses there is sufficient bandwidth to implement a broadband system in which legacy 1 Mbps 1553B waveforms could coexist with new 200 Mbps waveforms, thus providing an incremental high speed communication channel to existing MIL-STD-1553 buses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blum, R. D.; Srinivasan, S.; Kemper, F.
2014-11-01
K-band spectra are presented for a sample of 39 Spitzer Infrared Spectrograph (IRS) SAGE-Spec sources in the Large Magellanic Cloud. The spectra exhibit characteristics in very good agreement with their positions in the near-infrared—Spitzer color-magnitude diagrams and their properties as deduced from the Spitzer IRS spectra. Specifically, the near-infrared spectra show strong atomic and molecular features representative of oxygen-rich and carbon-rich asymptotic giant branch stars, respectively. A small subset of stars was chosen from the luminous and red extreme ''tip'' of the color-magnitude diagram. These objects have properties consistent with dusty envelopes but also cool, carbon-rich ''stellar'' cores. Modest amountsmore » of dust mass loss combine with the stellar spectral energy distribution to make these objects appear extreme in their near-infrared and mid-infrared colors. One object in our sample, HV 915, a known post-asymptotic giant branch star of the RV Tau type, exhibits CO 2.3 μm band head emission consistent with previous work that demonstrates that the object has a circumstellar disk.« less
Yang, Ji-Chun; Yin, Xue-Bo
2017-01-01
In this study, we report the synthesis and application of mesoporous CoFe2O4@MIL-100(Fe) hybrid magnetic nanoparticles (MNPs) for the simultaneous removal of inorganic arsenic (iAs). The hybrid adsorbent had a core-shell and mesoporous structure with an average diameter of 260 nm. The nanoscale size and mesoporous character impart a fast adsorption rate and high adsorption capacity for iAs. In total, 0.1 mg L−1 As(V) and As(III) could be adsorbed within 2 min, and the maximum adsorption capacities were 114.8 mg g−1 for As(V) and 143.6 mg g−1 for As(III), higher than most previously reported adsorbents. The anti-interference capacity for iAs adsorption was improved by the electrostatic repulsion and size exclusion effects of the MIL-100(Fe) shell, which also decreased the zero-charge point of the hybrid absorbent for a broad pH adsorption range. The adsorption mechanisms of iAs on the MNPs are proposed. An Fe-O-As structure was formed on CoFe2O4@MIL-100(Fe) through hydroxyl substitution with the deprotonated iAs species. Monolayer adsorption of As(V) was observed, while hydrogen bonding led to the multi-layer adsorption of neutral As(III) for its high adsorption capacity. The high efficiency and the excellent pH- and interference-tolerance capacities of CoFe2O4@MIL-100(Fe) allowed effective iAs removal from natural water samples, as validated with batch magnetic separation mode and a portable filtration strategy. PMID:28102334
NASA Astrophysics Data System (ADS)
Yang, Ji-Chun; Yin, Xue-Bo
2017-01-01
In this study, we report the synthesis and application of mesoporous CoFe2O4@MIL-100(Fe) hybrid magnetic nanoparticles (MNPs) for the simultaneous removal of inorganic arsenic (iAs). The hybrid adsorbent had a core-shell and mesoporous structure with an average diameter of 260 nm. The nanoscale size and mesoporous character impart a fast adsorption rate and high adsorption capacity for iAs. In total, 0.1 mg L-1 As(V) and As(III) could be adsorbed within 2 min, and the maximum adsorption capacities were 114.8 mg g-1 for As(V) and 143.6 mg g-1 for As(III), higher than most previously reported adsorbents. The anti-interference capacity for iAs adsorption was improved by the electrostatic repulsion and size exclusion effects of the MIL-100(Fe) shell, which also decreased the zero-charge point of the hybrid absorbent for a broad pH adsorption range. The adsorption mechanisms of iAs on the MNPs are proposed. An Fe-O-As structure was formed on CoFe2O4@MIL-100(Fe) through hydroxyl substitution with the deprotonated iAs species. Monolayer adsorption of As(V) was observed, while hydrogen bonding led to the multi-layer adsorption of neutral As(III) for its high adsorption capacity. The high efficiency and the excellent pH- and interference-tolerance capacities of CoFe2O4@MIL-100(Fe) allowed effective iAs removal from natural water samples, as validated with batch magnetic separation mode and a portable filtration strategy.
MIL-68 (In) nano-rods for the removal of Congo red dye from aqueous solution.
Jin, Li-Na; Qian, Xin-Ye; Wang, Jian-Guo; Aslan, Hüsnü; Dong, Mingdong
2015-09-01
MIL-68 (In) nano-rods were prepared by a facile solvothermal synthesis using NaOAc as modulator agent at 100°C for 30 min. The BET test showed that the specific surface area and pore volume of MIL-68 (In) nanorods were 1252 m(2) g(-1) and 0.80 cm(3) g(-1), respectively. The as-prepared MIL-68 (In) nanorods showed excellent adsorption capacity and rapid adsorption rate for removal of Congo red (CR) dye from water. The maximum adsorption capacity of MIL-68 (In) nanorods toward CR reached 1204 mg g(-1), much higher than MIL-68 (In) microrods and most of the previously reported adsorbents. The adsorption process of CR by MIL-68 (In) nano-rods was investigated and found to be obeying the Langmuir adsorption model in addition to pseudo-second-order rate equation. Moreover, the MIL-68 (In) nanorods showed an acceptable reusability after regeneration with ethanol. All information gives an indication that the as-prepared MIL-68 (In) nanorods show their potential as the adsorbent for highly efficient removal of CR in wastewater. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Glass, Dean E.; Olah, George A.; Prakash, G. K. Surya
2017-06-01
For the large scale fuel cell manufacture, the catalyst loading and layer thickness are critical factors affecting the performance and cost of membrane electrode assemblies (MEAs). The influence of catalyst layer thicknesses at the anode of a PEM based direct methanol fuel cell (DMFC) has been investigated. Catalysts were applied with the drawdown method with varied thicknesses ranging from 1 mil to 8 mils (1 mil = 25.4 μm) with a Pt/Ru anode loading of 0.25 mg cm-2 to 2.0 mg cm-2. The MEAs with the thicker individual layers (8 mils and 4 mils) performed better overall compared to the those with the thinner layers (1 mil and painted). The peak power densities for the different loading levels followed an exponential decrease of Pt/Ru utilization at the higher loading levels. The highest power density achieved was 49 mW cm-2 with the 4 mil layers at 2.0 mg cm-2 catalyst loading whereas the highest normalized power density was 116 mW mg-1 with the 8 mil layers at 0.25 mg cm-2 loading. The 8 mil drawdowns displayed a 50% and 23% increase in normalized power density compared to the 1 mil drawdowns at 0.25 mg cm-2 and 0.5 mg cm-2 loadings, respectively.
Wu, Bulong; Luo, Xiaobing; Zheng, Huai; Liu, Sheng
2011-11-21
Gold wire bonding is an important packaging process of lighting emitting diode (LED). In this work, we studied the effect of gold wire bonding on the angular uniformity of correlated color temperature (CCT) in white LEDs whose phosphor layers were coated by freely dispersed coating process. Experimental study indicated that different gold wire bonding impacts the geometry of phosphor layer, and it results in different fluctuation trends of angular CCT at different spatial planes in one LED sample. It also results in various fluctuating amplitudes of angular CCT distributions at the same spatial plane for samples with different wire bonding angles. The gold wire bonding process has important impact on angular uniformity of CCT in LED package. © 2011 Optical Society of America
Eclipse Science Results from the Airborne Infrared Spectrometer (AIR-Spec)
NASA Astrophysics Data System (ADS)
Samra, J.; Cheimets, P.; DeLuca, E.; Golub, L.; Judge, P. G.; Lussier, L.; Madsen, C. A.; Marquez, V.; Tomczyk, S.; Vira, A.
2017-12-01
We present the first science results from the commissioning flight of the Airborne Infrared Spectrometer (AIR-Spec), an innovative solar spectrometer that will observe the 2017 solar eclipse from the NSF/NCAR High-Performance Instrumented Airborne Platform for Environmental Research (HIAPER). During the eclipse, AIR-Spec will image five magnetically sensitive coronal emission lines between 1.4 and 4 microns to determine whether they may be useful probes of coronal magnetism. The instrument will measure emission line intensity, FWHM, and Doppler shift from an altitude of over 14 km, above local weather and most of the absorbing water vapor. Instrumentation includes an image stabilization system, feed telescope, grating spectrometer, infrared camera, and visible slit-jaw imager. Results from the 2017 eclipse are presented in the context of the mission's science goals. AIR-Spec will identify line strengths as a function of position in the solar corona and search for the high frequency waves that are candidates for heating and acceleration of the solar wind. The instrument will also identify large scale flows in the corona, particularly in polar coronal holes. Three of the five lines are expected to be strong in coronal hole plasmas because they are excited in part by scattered photospheric light. Line profile analysis will probe the origins of the fast and slow solar wind. Finally, the AIR-Spec measurements will complement ground based eclipse observations to provide detailed plasma diagnostics throughout the corona. AIR-Spec will measure infrared emission of ions observed in the visible from the ground, giving insight into plasma heating and acceleration at radial distances inaccessible to existing or planned spectrometers.
MultiSpec—a tool for multispectral hyperspectral image data analysis
NASA Astrophysics Data System (ADS)
Biehl, Larry; Landgrebe, David
2002-12-01
MultiSpec is a multispectral image data analysis software application. It is intended to provide a fast, easy-to-use means for analysis of multispectral image data, such as that from the Landsat, SPOT, MODIS or IKONOS series of Earth observational satellites, hyperspectral data such as that from the Airborne Visible-Infrared Imaging Spectrometer (AVIRIS) and EO-1 Hyperion satellite system or the data that will be produced by the next generation of Earth observational sensors. The primary purpose for the system was to make new, otherwise complex analysis tools available to the general Earth science community. It has also found use in displaying and analyzing many other types of non-space related digital imagery, such as medical image data and in K-12 and university level educational activities. MultiSpec has been implemented for both the Apple Macintosh ® and Microsoft Windows ® operating systems (OS). The effort was first begun on the Macintosh OS in 1988. The GLOBE ( http://www.globe.gov) program supported the development of a subset of MultiSpec for the Windows OS in 1995. Since then most (but not all) of the features in the Macintosh OS version have been ported to the Windows OS version. Although copyrighted, MultiSpec with its documentation is distributed without charge. The Macintosh and Windows versions and documentation on its use are available from the World Wide Web at URL: http://dynamo.ecn.purdue.edu/˜biehl/MultiSpec/ MultiSpec is copyrighted (1991-2001) by Purdue Research Foundation, West Lafayette, Indiana 47907.
NASA Technical Reports Server (NTRS)
Wingard, Doug
2006-01-01
After the rollout of Space Shuttle Discovery in April 2005 in preparation for return-to-flight, there was a failure of the Orbiter (OV-103) helium signature leak test in the gaseous hydrogen (GH2) system. Leakage was attributed to the Flow Control Valve (FCV) in Main Engine 3. The FCV determined to be the source of the leak for OV-103 is designated as LV-58. The nitrile/Buna N rubber O-ring seal was removed from LV-58, and failure analysis indicated radial cracks providing leak paths in one quadrant. Cracks were eventually found in 6 of 9 FCV O-rings among the three Shuttle Orbiters, though none were as severe as those for LV-58, OV-103. Testing by EM10 at MSFC on all 9 FCV O- rings included: laser dimensional, Shore A hardness and properties from a dynamic mechanical analyzer (DMA) and an Instron tensile machine. The following test data was obtained on the cracked quadrant of the LV-58, OV-103 O-ring: (1) the estimated compression set was only 9.5%, compared to none for the rest of the O-ring; (2) Shore A hardness for the O.D. was higher by almost 4 durometer points than for the rest of the O-ring; and (3) DMA data showed that the storage/elastic modulus E was almost 25% lower than for the rest of the O-ring. Of the 8 FCV O-rings tested on an Instron, 4 yielded tensile strengths that were below the MIL spec requirement of 1350 psi-a likely influence of rubber cracking. Comparisons were made between values of modulus determined by DNA (elastic) and Instron (Young s). Each nitrile/Buna N O-ring used in the FCV conforms to the MIL-P-25732C specification. A number of such O-rings taken from shelf storage at MSFC and Kennedy Space Center (KSC) were used to generate a reference curve of DMA glass transition temperature (Tg) vs. shelf storage time ranging from 8 to 26 years. A similar reference curve of TGA onset temperature (of rubber weight loss) vs. shelf storage time was also generated. The DMA and TGA data for the used FCV O-rings were compared to the reference curves. Correlations were also made between the DMA modulus (at 22 C) and Shore A hardness for all 9 of the FCV O-rings used among the three Shuttle Orbiters. The radial cracking in the FCV O-rings was determined to be due to ozone attack, as nitrile/Buna N rubber is susceptible to such attack. Nitrile/Buna N material under MIL-P25732C should be used in a hydraulic fluid environment to help protect it from cracking. However, the FCV O-rings were used in an air only environment. The FCV design has as much as a 9-mil gap that allows the O.D. of the O-ring to be directly exposed to ozone, pressurized air and some elevated temperatures, accelerating the weathering process that leads to O-ring cracking. Space Shuttle flights will likely not continue past 2010. Therefore, Shuttle management decided to continue using the nitrile/Buna N material for the FCVs, but have each O-ring replaced after 3 years to minimize any chances for crack initiation.
A mutli-technique search for the most primitive CO chondrites
NASA Astrophysics Data System (ADS)
Alexander, C. M. O'D.; Greenwood, R. C.; Bowden, R.; Gibson, J. M.; Howard, K. T.; Franchi, I. A.
2018-01-01
As part of a study to identify the most primitive COs and to look for weakly altered CMs amongst the COs, we have conducted a multi-technique study of 16 Antarctic meteorites that had been classified as primitive COs. For this study, we have determined: (1) the bulk H, C and N abundances and isotopes, (2) bulk O isotopic compositions, (3) bulk modal mineralogies, and (4) for some selected samples the abundances and compositions of their insoluble organic matter (IOM). Two of the 16 meteorites do appear to be CMs - BUC 10943 seems to be a fairly typical CM, while MIL 090073 has probably been heated. Of the COs, DOM 08006 appears to be the most primitive CO identified to date and is quite distinct from the other members of its pairing group. The other COs fall into two groups that are less primitive than DOM 08006 and ALH 77307, the previously most primitive CO. The first group is composed of members of the DOM 08004 pairing group, except DOM 08006. The second group is composed of meteorites belonging to the MIL 03377 and MIL 07099 pairing groups. These two pairing groups should probably be combined. There is a dichotomy in the bulk O isotopes between the primitive (all Antarctic finds) and the more metamorphosed COs (mostly falls). This dichotomy can only partly be explained by the terrestrial weathering experienced by the primitive Antarctic samples. It seems that the more equilibrated samples interacted to a greater extent with 16O-poor material, probably water, than the more primitive meteorites.
Bibliography on aircraft fire hazards and safety. Volume 1: Hazards. Part 1: Key numbers 1 to 817
NASA Technical Reports Server (NTRS)
Pelouch, J. J., Jr. (Compiler); Hacker, P. T. (Compiler)
1974-01-01
Ignition temperatures of n-hexane, n-octane, n-decane, JP-6 jet fuel, and aircraft engine oil MIL-7-7808 (0-60-18) were determined in air using heated Pyrex cylinders and Nichrome wires, rods, or tubes. Ignition temperature varied little with fuel-air ratio, but increased as the size of the heat source was decreased. Expressions are given which define the variation of the hot surface ignition temperatures of these combustibles with the radius and the surface area of the heat source. The expressions are applicable to stagnant or low velocity flow conditions (less than 0.2 in./sec.). In addition, the hot gas ignition temperatures of the combustible vapor-air mixtures were determined with jets of hot air. These ignition temperatures also varied little with fuel-air ratio and increased as the diameter of the heat sources was decreased.
Universal Reconfigurable Translator Module (URTM) Final Report
NASA Technical Reports Server (NTRS)
Leventhal, Edward; Machan, Roman; Jones, Rob
2009-01-01
This report describes the Universal Reconfigurable Translation Module, or URTM. The URTM was developed by Sigma Space Corporation for NASA in order to translate specific serial protocols, both logically and physically. At present, the prototype configuration has targeted MIL-STD-1553B (RT and BC), IEEE 1394b (Firewire), and ECSS-E-50-12A (SpaceWire). The objectives of this program were to study the feasibility of a configurable URTM to translate serial link data as might be used in a space-flight mission and to design, develop, document, and deliver an engineering prototype model of the URTM with a path to spaceflight. By simply connecting two of the three Physical Interface Modules (PIM) on either end of the RPTM (Reconfigurable Protocol Translator Module), the URTM then self configures via a library of interface translation functions, thereby allowing the two data links to communicate seamlessly.
Training Command EDIT Region Legal Service Office Japan Facebook EDIT Region Legal Service Office Mid Navy.mil Home Page Navy.mil Home Page Subscribe to Navy News Service Search Navy.mil Navy.mil Training and Readiness Center Facebook EDIT Afloat Training Group Mayport Facebook EDIT Afloat Training
NASA Astrophysics Data System (ADS)
Han, Tongtong; Li, Caifeng; Guo, Xiangyu; Huang, Hongliang; Liu, Dahuan; Zhong, Chongli
2016-12-01
A series of SiO2@aluminum-MOF(MIL-68) composites with different SiO2 loadings have been synthesized by a simple and mild compositing strategy for high-efficiency removal of aniline. As evidenced from SEM and TEM images as well as the particle size distribution, the incorporation of SiO2 can improve the dispersity of MIL-68(Al) in composites, and result in the smaller particle size than that of pristine MIL-68(Al). Besides, the adsorption of aniline over SiO2, MIL-68(Al), the physical mixture of these two materials, and SiO2@MIL-68(Al) composites was investigated comparatively, demonstrating a relatively high adsorption capacity (531.9 mg g-1) of 7% SiO2@MIL-68(Al) towards aniline. Combining the ultrafast adsorption dynamics (reaching equilibrium within 40 s) and great reusability, 7% SiO2@MIL-68(Al) shows excellent adsorption performance. This indicates that the SiO2@MIL-68(Al) composites possess great potential applications as a kind of fascinating adsorbent in water pollution protection.
Hicks, Joshua A; Trent, Jason; Davis, William E; King, Laura A
2012-03-01
Four studies tested the prediction that positive affect (PA) would relate more strongly to meaning in life (MIL) as a function of perceived time limitations. In Study 1 (N = 360), adults completed measures of PA and MIL. As predicted, PA related more strongly to MIL for older, compared to younger, participants. In Studies 2 and 3, adults (N = 514) indicated their current position in their life span, and rated their MIL. PA, whether naturally occurring (Study 2) or induced (Study 3), was a stronger predictor of MIL for individuals who perceived themselves as having a limited amount of time left to live. Finally, in Study 4 (N = 98) students completed a measure of PA, MIL, and future time perspective (FTP). Results showed that PA was more strongly linked to MIL for those who believed they had fewer opportunities left to pursue their goals. Overall, these findings suggest that the experience of PA becomes increasingly associated with the experience of MIL as the perception of future time becomes limited. The contribution of age related processes to judgments of well-being are discussed.
The Chlorine Isotope Composition of Martian Meteorites
NASA Astrophysics Data System (ADS)
Sharp, Z. D.; Shearer, C. K.; Agee, C.; Burger, P. V.; McKeegan, K. D.
2014-11-01
The Cl isotope composition of martian meteorites range from -3.8 to +8.6 per mil. Ol-phyric shergottites are lightest; crustally contaminated samples are heaviest, basaltic shergottites are in-between. The system is explained as two component mixing.
Germanium and Rare Earth Element accumulation in woody bioenergy crops
NASA Astrophysics Data System (ADS)
Hentschel, Werner
2016-04-01
Germanium and REEs are strategic elements that are used for high tech devices and engineered systems, however these elements are hardly concentrated into mineable ore deposits. Since these elements occur widely dispersed in the earth crust with concentrations of several mgṡkg-1 (Ge 1.6 mgṡkg-1, Nd 25 mgṡkg-1) a new possibility to gain these elements could be phytomining, a technique that uses plants to extract elements from soils via their roots. Since knowledge about accumulating plant species is quite limited we conducted research on the concentrations of strategic elements in wood and leaves of fast growing tree species (Salix spec., Populus spec., Betula pendula, Alnus glutinosa, Fraxinus excelsior, Acer pseudoplatanus). In total 35 study sites were selected in the mining affected area around Freiberg (Saxony, Germany), differing in their species composition and degree of contamination with toxic trace metals (Pb, As, Cd). On each site plant tissues (wood and leaves, respectively) of different species were sampled. In addition soil samples were taken from a soil depth of 0 - 30 cm and 30 - 60 cm. The aim of our work was to investigate correlations between the concentrations of the target elements in plant tissues and soil characteristics like pH, texture, nutrients and concentrations in six operationally defined soil fractions (mobile, acid soluble, oxidizable, amorphic oxides, crystalline oxides, residual or siliceous). Concentrations of elements in soil extracts and plant tissues were measured with ICP-MS. The element Nd was selected as representative for the group of REEs, since this element showed a high correlation with the concentrations of the other REE We found that the concentration of Nd in the leaves (0.31 mgṡkg-1Nd) were several times higher than in herbaceous species (0.05 mgṡkg-1 Nd). The concentration of Ge in leaves were ten times lower than that of Nd whereas in herbaceous species Nd and Ge were in equal magnitude. Within the tree species Populus spec. (0.77 mgṡkg-1) and Salix spec. (0.36 mgṡkg-1) showed by far the highest concentrations of Nd in leaves. Fraxinus excelsior (0.10 mgṡkg-1) and Betula pendula (0.06 mgṡkg-1) feature the lowest concentrations of Nd in leaves. We found significant correlations between the concentration of the target elements in the plant tissue and the concentration of these elements in the first steps of the sequential extraction of the soil samples. These studies have been carried out in the framework of the PhytoGerm project financed by the Federal Ministry of Education and Research, Germany.
SpecTracer: A Python-Based Interactive Solution for Echelle Spectra Reduction
NASA Astrophysics Data System (ADS)
Romero Matamala, Oscar Fernando; Petit, Véronique; Caballero-Nieves, Saida Maria
2018-01-01
SpecTracer is a newly developed interactive solution to reduce cross dispersed echelle spectra. The use of widgets saves the user the steep learning curves of currently available reduction software. SpecTracer uses well established image processing techniques based on IRAF to succesfully extract the stellar spectra. Comparisons with other reduction software, like IRAF, show comparable results, with the added advantages of ease of use, platform independence and portability. This tool can obtain meaningful scientific data and serve also as a training tool, especially for undergraduates doing research, in the procedure for spectroscopic analysis.
Vďačný, Peter; Foissner, Wilhelm
2017-04-01
Six metopid ciliates from soil of the Murray River floodplain in Australia were studied using live observation, various silver impregnation methods, scanning electron microscopy, and multivariate statistics. One of the species is affiliated with M. setosus while the others represent new taxa. Metopus filum nov. spec. is distinguished from most congeners by the slender body, the absence of cortical granules, and the low number of ciliary rows and adoral polykinetids. Metopus palaeformides nov. spec. most resembles Heterometopus palaeformis (Kahl, 1927) Foissner, 2016b but they can be distinguished by body size, the number of adoral polykinetids, and the oral area pattern. Metopus murrayensis nov. spec. is outstanding in having a globular macronucleus surrounded by innumerable refractive granules and a conspicuously thick preoral dome. Metopus rex nov. spec. and M. magnus nov. spec. are easily distinguished from most congeners by their large body size and the shape of the macronucleus. Moreover, M. rex displays up to 30μm long endosymbiotic bacteria while the micronucleus of M. magnus is uniquely situated in a small macronuclear concavity. Multivariate statistics corroborates the distinctness of these six metopid populations. Copyright © 2016 Elsevier GmbH. All rights reserved.
NASA Astrophysics Data System (ADS)
Cataldo, G.; Barrentine, E. M.; Bulcha, B. T.; Ehsan, N.; Hess, L. A.; Noroozian, O.; Stevenson, T. R.; U-Yen, K.; Wollack, E. J.; Moseley, S. H.
2018-04-01
Micro-Spec (µ-Spec) is a direct-detection spectrometer which integrates all the components of a diffraction-grating spectrometer onto a ˜ 10-cm^2 chip through the use of superconducting microstrip transmission lines on a single-crystal silicon substrate. A second-generation µ-Spec is being designed to operate with a spectral resolution of 512 in the submillimeter (500-1000 µm, 300-600 GHz) wavelength range, a band of interest for several spectroscopic applications in astrophysics. High-altitude balloon missions would provide the first test bed to demonstrate the µ-Spec technology in a space-like environment and would be an economically viable venue for multiple observation campaigns. This work reports on the current status of the instrument design and will provide a brief overview of each instrument subsystem. Particular emphasis will be given to the design of the spectrometer's two-dimensional diffractive region, through which the light of different wavelengths is focused on the detectors along the focal plane. An optimization process is employed to generate geometrical configurations of the diffractive region that satisfy specific requirements on spectrometer size, operating spectral range, and performance. An optical design optimized for balloon missions will be presented in terms of geometric layout, spectral purity, and efficiency.
SPECS: the kilometer-baseline far-IR interferometer in NASA's space science roadmap
NASA Astrophysics Data System (ADS)
Leisawitz, David T.; Abel, Tom; Allen, Ronald J.; Benford, Dominic J.; Blain, Andrew; Bombardelli, Claudio; Calzetti, Daniela; DiPirro, Michael J.; Ehrenfreund, Pascale; Evans, Neal J., II; Fischer, Jacqueline; Harwit, Martin; Hyde, Tristram T.; Kuchner, Marc J.; Leitner, Jesse A.; Lorenzini, Enrico C.; Mather, John C.; Menten, Karl M.; Moseley, Samuel H., Jr.; Mundy, Lee G.; Nakagawa, Takao; Neufeld, David A.; Pearson, John C.; Rinehart, Stephen A.; Roman, Juan; Satyapal, Shobita; Silverberg, Robert F.; Stahl, H. Philip; Swain, Mark R.; Swanson, Theodore D.; Traub, Wesley A.; Wright, Edward L.; Yorke, Harold W.
2004-10-01
Ultimately, after the Single Aperture Far-IR (SAFIR) telescope, astrophysicists will need a far-IR observatory that provides angular resolution comparable to that of the Hubble Space Telescope. At such resolution galaxies at high redshift, protostars, and nascent planetary systems will be resolved, and theoretical models for galaxy, star, and planet formation and evolution can be subjected to important observational tests. This paper updates information provided in a 2000 SPIE paper on the scientific motivation and design concepts for interferometric missions SPIRIT (the Space Infrared Interferometric Telescope) and SPECS (the Submillimeter Probe of the Evolution of Cosmic Structure). SPECS is a kilometer baseline far-IR/submillimeter imaging and spectral interferometer that depends on formation flying, and SPIRIT is a highly-capable pathfinder interferometer on a boom with a maximum baseline in the 30 - 50 m range. We describe recent community planning activities, remind readers of the scientific rationale for space-based far-infrared imaging interferometry, present updated design concepts for the SPIRIT and SPECS missions, and describe the main issues currently under study. The engineering and technology requirements for SPIRIT and SPECS, additional design details, recent technology developments, and technology roadmaps are given in a companion paper in the Proceedings of the conference on New Frontiers in Stellar Interferometry.
NASA Technical Reports Server (NTRS)
Kessel, Kurt R.
2014-01-01
The purpose of this testing is to determine the suitability of trivalent chromium conversion coatings that meet the requirements of MIL-DTL-5541, Type II, for use in applications where high-frequency electrical performance is important. This project will evaluate the ability of coated aluminum to form adequate EMI seals. Testing will assess performance of the trivalent chromium coatings against the known control hexavalent chromium MIL-DTL-5541 Type I Class 3 before and after they have been exposed to a set of environmental conditions. Performance will be assessed by evaluating shielding effectiveness (SE) test data from a variety of test samples comprised of different aluminum types and/or conversion coatings.
Knebel, Alexander; Friebe, Sebastian; Bigall, Nadja Carola; Benzaqui, Marvin; Serre, Christian; Caro, Jürgen
2016-03-23
MIL-96(Al) layers were prepared as supported metal-organic frameworks membrane via reactive seeding using the α-alumina support as the Al source for the formation of the MIL-96(Al) seeds. Depending on the solvent mixture employed during seed formation, two different crystal morphologies, with different orientation of the transport-active channels, have been formed. This crystal orientation and habit is predefined by the seed crystals and is kept in the subsequent growth of the seeds to continuous layers. In the gas separation of an equimolar H2/CO2 mixture, the hydrogen permeability of the two supported MIL-96(Al) layers was found to be highly dependent on the crystal morphology and the accompanied channel orientation in the layer. In addition to the neat supported MIL-96(Al) membrane layers, mixed-matrix membranes (MMMs, 10 wt % filler loading) as a composite of MIL-96(Al) particles as filler in a continuous Matrimid polymer phase have been prepared. Five particle sizes of MIL-96(Al) between 3.2 μm and 55 nm were synthesized. In the preparation of the MIL-96(Al)/Matrimid MMM (10 wt % filler loading), the following preparation problems have been identified: The bigger micrometer-sized MIL-96(Al) crystals show a trend toward sedimentation during casting of the MMM, whereas for nanoparticles aggregation and recrystallization to micrometer-sized MIL-96(Al) crystals has been observed. Because of these preparation problems for MMM, the neat supported MIL-96(Al) layers show a relatively high H2/CO2 selectivity (≈9) and a hydrogen permeance approximately 2 magnitudes higher than that of the best MMM.
Fog collecting biomimetic surfaces: Influence of microstructure and wettability.
Azad, M A K; Ellerbrok, D; Barthlott, W; Koch, K
2015-01-19
We analyzed the fog collection efficiency of three different sets of samples: replica (with and without microstructures), copper wire (smooth and microgrooved) and polyolefin mesh (hydrophilic, superhydrophilic and hydrophobic). The collection efficiency of the samples was compared in each set separately to investigate the influence of microstructures and/or the wettability of the surfaces on fog collection. Based on the controlled experimental conditions chosen here large differences in the efficiency were found. We found that microstructured plant replica samples collected 2-3 times higher amounts of water than that of unstructured (smooth) samples. Copper wire samples showed similar results. Moreover, microgrooved wires had a faster dripping of water droplets than that of smooth wires. The superhydrophilic mesh tested here was proved more efficient than any other mesh samples with different wettability. The amount of collected fog by superhydrophilic mesh was about 5 times higher than that of hydrophilic (untreated) mesh and was about 2 times higher than that of hydrophobic mesh.
KiwiSpec - an advanced spectrograph for high resolution spectroscopy: optical design and variations
NASA Astrophysics Data System (ADS)
Barnes, Stuart I.; Gibson, Steve; Nield, Kathryn; Cochrane, Dave
2012-09-01
The KiwiSpec R4-100 is an advanced high resolution spectrograph developed by KiwiStar Optics, Industrial Research Ltd, New Zealand. The instrument is based around an R4 echelle grating and a 100mm collimated beam diameter. The optical design employs a highly asymmetric white pupil design, whereby the transfer collimator has a focal length only 1/3 that of the primary collimator. This allows the cross-dispersers (VPH gratings) and camera optics to be small and low cost while also ensuring a very compact instrument. The KiwiSpec instrument will be bre-fed and is designed to be contained in both thermal and/or vacuum enclosures. The instrument concept is highly exible in order to ensure that the same basic design can be used for a wide variety of science cases. Options include the possibility of splitting the wavelength coverage into 2 to 4 separate channels allowing each channel to be highly optimized for maximum eciency. CCDs ranging from smaller than 2K2K to larger than 4K4K can be accommodated. This allows good (3-4 pixel) sampling of resolving powers ranging from below 50,000 to greater than 100,000. Among the specic design options presented here will be a two-channel concept optimized for precision radial velocities, and a four-channel concept developed for the Gemini High- Resolution Optical Spectrograph (GHOST). The design and performance of a single-channel prototype will be presented elsewhere in these proceedings.
Ruppert, Leslie F.; Trippi, Michael H.; Fedorko, Nick; Grady, William C.; Eble, Cortland F.; Schuller, William A.; Ruppert, Leslie F.; Ryder, Robert T.
2014-01-01
Methane contents of desorbed gas from coal samples in the Meadowfill Landfill study area ranged from 14.87 to 98.73 percent (corrected for air contamination) for the Harlem coal bed and Clarion coal zone, respectively. Proportions of methane to the sum of the higher molecular weight hydrocarbons ranged from about 40 to 340 as the desorbed gas contained only a small percentage of higher weight hydrocarbons. Coalbed methane from the Upper Kittanning upper split and the Upper Kittanning coal beds is thermogenic in origin with isotopic composition of carbon (carbon 13, 13C) in methane (expressed as δ13C in units of parts per thousand (per mil) relative to the Vienna Peedee belemnite (VPDB) standard) ranging from -46.6 to -48.7 per mil. Coalbed methane from the Brush Creek and Upper Freeport coal beds and the Clarion coal zone contains some biogenic methane with δ13C values ranging from -51.05 to -51.56 per mil.
Microstructure study of direct laser fabricated Ti alloys using powder and wire
NASA Astrophysics Data System (ADS)
Wang, Fude; Mei, J.; Wu, Xinhua
2006-11-01
A compositionally graded material has been fabricated using direct laser fabrication (DFL). Two types of feedstock were fed simultaneously into the laser focal point, a burn resistant (BurTi) alloy Ti-25V-15Cr-2Al-0.2C powder and a Ti-6Al-4V wire. The local composition of the alloy was changed by altering the ratio of powder to wire by varying the feed rate of the powder whilst maintaining a fixed feed rate of wire-feed. For the range of compositions between about 20% and 100% BurTi only the beta phase was observed and the composition and lattice parameter varied monotonically. The grain size was found to be much finer in these functionally graded samples than in laser fabricated Ti64. Some samples were made using the wire-feed alone, where it was found that the microstructure is different from that found when using powder feed alone. The results are discussed in terms of the power requirements for laser fabrication of powder and wire samples.
Assessment of Refueling Hose Visibility: Post-Cleaning Evaluation
2013-10-01
Cott, H.P., and Kinkade, R.G. (Eds.), Human Engineering Guide to Equipment Design. Washington, DC: GPO. F-35 Gen 5 HMDS spec for minimum...spectral band sensors: visible, near IR, and short-wave IR. These images will be captured for each of the samples set up for both the geometries...Contrast Ratio Near IR Black Reflectance White Reflectance Contrast Ratio Short Wave IR Black
Reliability Criteria for Thick Bonding Wire.
Dagdelen, Turker; Abdel-Rahman, Eihab; Yavuz, Mustafa
2018-04-17
Bonding wire is one of the main interconnection techniques. Thick bonding wire is widely used in power modules and other high power applications. This study examined the case for extending the use of traditional thin wire reliability criteria, namely wire flexure and aspect ratio, to thick wires. Eleven aluminum (Al) and aluminum coated copper (CucorAl) wire samples with diameter 300 μm were tested experimentally. The wire response was measured using a novel non-contact method. High fidelity FEM models of the wire were developed and validated. We found that wire flexure is not correlated to its stress state or fatigue life. On the other hand, aspect ratio is a consistent criterion of thick wire fatigue life. Increasing the wire aspect ratio lowers its critical stress and increases its fatigue life. Moreover, we found that CucorAl wire has superior performance and longer fatigue life than Al wire.
Reliability Criteria for Thick Bonding Wire
Yavuz, Mustafa
2018-01-01
Bonding wire is one of the main interconnection techniques. Thick bonding wire is widely used in power modules and other high power applications. This study examined the case for extending the use of traditional thin wire reliability criteria, namely wire flexure and aspect ratio, to thick wires. Eleven aluminum (Al) and aluminum coated copper (CucorAl) wire samples with diameter 300 μm were tested experimentally. The wire response was measured using a novel non-contact method. High fidelity FEM models of the wire were developed and validated. We found that wire flexure is not correlated to its stress state or fatigue life. On the other hand, aspect ratio is a consistent criterion of thick wire fatigue life. Increasing the wire aspect ratio lowers its critical stress and increases its fatigue life. Moreover, we found that CucorAl wire has superior performance and longer fatigue life than Al wire. PMID:29673194
MIL-STD-2411-1 Change 3. Notice Impacts to NAVAIR
2010-07-30
is Steve Rogan, NGA OCIO CE, 314-676- 0292, rogans@nga.mil. METRIC MIL-STD-2411-1 w/CHANGE 3 ______________ SUPERCEDING MIL-STD-2411-1 Change...JN Jan Mayen Is (NO) JA Japan DQ Jarvis Island (US) JE Jersey (UK) JQ Johnston Atoll (US) JO Jordan JU Juan De Nova Islands (FR) YV Juan
East Europe Report, Economic and Industrial Affairs
1984-09-11
added (UW) , return on production assets ( RVF ), profit and exports. These categories characterize the results of the work of the whole organization...prescribed goals No of VHJ’s Increase No of VHJ’s Decrease UW (mil. of Kcs) 9 147.5 6 184.8 Profit (mil. of Kcs) 6 66.0 8 289.0 RVF /return on prod. 7... RVF (percentage) No of Workers ZSMP (mil. of Kcs) PSMP (mil. of Kcs) Average Wage (Kcs) Allocation from Profits to FR (mil. of Kcs) VHJ’s with
Pairing Relationships Among Feldspathic Lunar Meteorites from Miller Range, Antarctica
NASA Technical Reports Server (NTRS)
Zeigler, Ryan A.; Korotev, R. L.; Jolliff, B. L.
2012-01-01
The Miller Range ice fields have been amongst the most prolific for lunar meteorites that ANSMET has searched [1-3]. Six different stones have been recovered during the 2005, 2007, and 2009 field seasons: MIL 05035 (142 g), MIL 07006 (1.4 g), MIL 090034 (196 g), MIL 090036 (245 g), MIL 090070 (137 g), and MIL 090075 (144 g). Of these, the five stones collected during the 2007 and 2009 seasons are feldspathic breccias. Previous work on the Miller Range feldspathic lunar meteorites (FLMs) has suggested that they are not all paired with each other [4-5]. Here we examine the pairing relationships among the Miller Range FLMs using petrography in concert with traceand major-element compositions.
Spec2Harv: Converting Spectrum output to HARVEST input
Eric J. Gustafson; Luke V. Rasmussen; Larry A. Leefers
2003-01-01
Spec2Harv was developed to automate the conversion of harvest schedules generated by the Spectrum model into script files that can be used by the HARVEST simulation model to simulate the implementation of the Spectrum schedules in a spatially explicit way.
Comparative range of orthodontic wires.
Ingram, S B; Gipe, D P; Smith, R J
1986-10-01
ADA specification No. 32 for determining the range (elastic limit) of orthodontic wires uses the bending of a wire section treated as a cantilever beam. An alternative method for defining the range of orthodontic wires proposed by Waters (1981) is to wrap wire sections around mandrels of varying diameters and measure the deformation imparted after unwrapping. Four brass mandrels with a total of 46 test diameters ranging from 3.5 to 60.0 mm were used in this study. Wire sections 9 cm in length were rolled on the mandrel with a hand lathe. The mandrel cross section required to produce a predetermined amount of deformation (2 mm arc height for a 5 cm chord) was defined as the yield diameter for that particular wire. No individual wire was tested twice so as to avoid introduction of strain history. Test samples of 488 different orthodontic wires supplied by nine commercial distributors were evaluated (a total of 4,747 samples). Stainless steel wires of identical dimensions had a large variation in range, depending on the state of strain hardening and heat treatment. For example, 0.020 inch round wire had yield diameters ranging from 22.8 mm for Australian special plus orange (TP Laboratories) to 42.9 mm for Nubryte gold (G.A.C. International). Chromium cobalt wires had less range than stainless steel before heat treatment, but increased greatly in range after heat treatment. Nitinol (Unitek) had the greatest range of all wires tested (yield diameter of 8.7 mm for 0.016 inch Nitinol). Multistranded stainless steel wires had yield diameters between 9.0 and 14.0 mm.
Bacterial colonization on coated and uncoated orthodontic wires: A prospective clinical trial.
Raji, Seyed Hamid; Shojaei, Hasan; Ghorani, Parinaz Saeidi; Rafiei, Elahe
2014-11-01
The advantages of coated orthodontic wires such as esthetic and their effects on reduced friction, corrosion and allergic reaction and the significant consequences of plaque accumulation on oral health encouraged us to assess bacterial colonization on these wires. A total of 18 (9 upper and 9 lower) epoxy resin coated 16 × 22 nickel-titanium wires (Spectra, GAC, USA) and 18 (9 upper and 9 lower) non-coated 16 × 22 nickel-titanium wires (Sentalloy, GAC, USA) with isolated packages were selected and sterilized before application. The samples were divided randomly between upper and lower arches in 18 patients and hence that every patient received one coated and one uncoated wire at the same time. Samples were removed and cut in equal lengths after 3 weeks and placed in phosphate buffered saline buffer. After separation of bacteria in trypsin and ethylenediaminetetraacetic acid solution, the diluted solution was cultured in blood agar and bacterial colony forming units were counted. Finally, the data was analyzed using the paired t-test and the significance was set at 0.05. Mean of bacterial colonization on uncoated wires was more than that of coated wires (P < 0.001). Bacterial plaque accumulation on epoxy resin coated nickel-titanium orthodontic wires is significantly lower than uncoated nickel-titanium wires.
The upper critical field of filamentary Nb3Sn conductors
NASA Astrophysics Data System (ADS)
Godeke, A.; Jewell, M. C.; Fischer, C. M.; Squitieri, A. A.; Lee, P. J.; Larbalestier, D. C.
2005-05-01
We have examined the upper critical field of a large and representative set of present multifilamentary Nb3Sn wires and one bulk sample over a temperature range from 1.4 K up to the zero-field critical temperature. Since all present wires use a solid-state diffusion reaction to form the A15 layers, inhomogeneities with respect to Sn content are inevitable, in contrast to some previously studied homogeneous samples. Our study emphasizes the effects that these inevitable inhomogeneities have on the field-temperature phase boundary. The property inhomogeneities are extracted from field-dependent resistive transitions which we find broaden with increasing inhomogeneity. The upper 90%-99% of the transitions clearly separates alloyed and binary wires but a pure, Cu-free binary bulk sample also exhibits a zero-temperature critical field that is comparable to the ternary wires. The highest μ0Hc2 detected in the ternary wires are remarkably constant: The highest zero-temperature upper critical fields and zero-field critical temperatures fall within 29.5±0.3 and 17.8±0.3K, respectively, independent of the wire layout. The complete field-temperature phase boundary can be described very well with the relatively simple Maki-DeGennes model using a two-parameter fit, independent of composition, strain state, sample layout, or applied critical state criterion.
Shaw, C D; Lonchamp, J; Downing, T; Imamura, H; Freeman, T M; Cotton, J A; Sanders, M; Blackburn, G; Dujardin, J C; Rijal, S; Khanal, B; Illingworth, C J R; Coombs, G H; Carter, K C
2016-03-01
In this study, we followed the genomic, lipidomic and metabolomic changes associated with the selection of miltefosine (MIL) resistance in two clinically derived Leishmania donovani strains with different inherent resistance to antimonial drugs (antimony sensitive strain Sb-S; and antimony resistant Sb-R). MIL-R was easily induced in both strains using the promastigote-stage, but a significant increase in MIL-R in the intracellular amastigote compared to the corresponding wild-type did not occur until promastigotes had adapted to 12.2 μM MIL. A variety of common and strain-specific genetic changes were discovered in MIL-adapted parasites, including deletions at the LdMT transporter gene, single-base mutations and changes in somy. The most obvious lipid changes in MIL-R promastigotes occurred to phosphatidylcholines and lysophosphatidylcholines and results indicate that the Kennedy pathway is involved in MIL resistance. The inherent Sb resistance of the parasite had an impact on the changes that occurred in MIL-R parasites, with more genetic changes occurring in Sb-R compared with Sb-S parasites. Initial interpretation of the changes identified in this study does not support synergies with Sb-R in the mechanisms of MIL resistance, though this requires an enhanced understanding of the parasite's biochemical pathways and how they are genetically regulated to be verified fully. © 2015 The Authors. Molecular Microbiology published by John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pierson, Stephen A.; Nacham, Omprakash; Clark, Kevin D.
Magnetic ionic liquids (MILs) are distinguished from traditional ionic liquids (ILs) by the incorporation of a paramagnetic component within their chemical structure. Hydrophobic MILs are novel solvents that can be used in many applications, including liquid–liquid extraction (LLE) and catalysis. Low viscosity and low water solubility are essential features that determine their feasibility in LLE. Here, we synthesized extremely hydrophobic MILs by using transition and rare earth metal hexafluoroacetylacetonate chelated anions paired with the trihexyl(tetradecyl)phosphonium ([P 66614 +]) cation. Hydrophobic MILs exhibiting water solubilities less than 0.01% (v/v) were synthesized in a rapid two-step procedure. Furthermore, the viscosities of themore » MILs are among some of the lowest ever reported for hydrophobic MILs (276.5–927.9 centipoise (cP) at 23.7 °C) dramatically improving the ease of handling these liquids. For the first time, the magnetic properties of MILs possessing hexafluoroacetylacetonate chelated metal anions synthesized in this study are reported using a superconducting quantum interference device (SQUID) magnetometer. We also achieved an effective magnetic moments (μ eff) as high as 9.7 and 7.7 Bohr magnetons (μ B) by incorporating high spin dysprosium and gadolinium ions, respectively, into the anion component of the MIL. The low viscosity, high hydrophobicity, and large magnetic susceptibility of these MILs make them highly attractive and promising solvents for separations and purification, liquid electrochromic materials, catalytic studies, as well as microfluidic applications.« less
Liu, Kai; Gao, Yanxin; Liu, Jing; Wen, Yifan; Zhao, Yingcan; Zhang, Kunyang; Yu, Gang
2016-04-05
Promising applications of metal-organic frameworks (MOFs) in various fields have raised concern over their environmental fate and safety upon inevitable discharge into aqueous environments. Currently, no information regarding the transformation processes of MOFs is available. Due to the presence of repetitive π-bond structure and semiconductive property, photochemical transformations are an important fate process that affects the performance of MOFs in practical applications. In the current study, the generation of reactive oxygen species (ROS) in isoreticular MIL-53s was studied. Scavengers were employed to probe the production of (1)O2, O2(•-), and •OH, respectively. In general, MIL-53(Cr) and MIL-53(Fe) are dominated by type I and II photosensitization reactions, respectively, and MIL-53(Al) appears to be less photoreactive. The generation of ROS in MIL-53(Fe) may be underestimated due to dismutation. Further investigation of MIL-53(Fe) encapsulated diclofenac transformation revealed that diclofenac can be easily transformed by MIL-53(Fe) generated ROS. However, the cytotoxicity results implied that the ROS generated from MIL-53s have little effect on the viability of the human hepatocyte (HepG2) cell line. These results suggest that the photogeneration of ROS by MOFs may be metal-node dependent, and the application of MIL-53s as drug carriers needs to be carefully considered due to their high photoreactivity.
Fly-by-Light Advanced Systems Hardware (FLASH) program
NASA Astrophysics Data System (ADS)
Bedoya, Carlos A.
1995-05-01
Fiber optics are immune to electromagnetic emissions and have the potential to eliminate this concern especially in flight critical applications if they can be developed to the same level of technology as current systems using wire to carry the signals. As aircraft become more and more dependent of digital signals to control all systems, the Electromagnetic Environment (EME) will become more and more a concern for the safe long term operation. The International Severe HIRF electromagnetic environment (EME) is less than 2000 Volts per meter below 400 MHz and reaches a maximum of 6,850 Volts per meter in the 4-6 GHz range. The normal assumption is that a metal or composite aircraft skin with appropriate seals provides 20 dB attenuation of the external environment. This reduces peak levels at the avionics boxes to less than 200 Volts per meter below 400 MHz and a maximum of 685 Volts per meter in the 406 GHz range. MIL-STD-461D imposed an additional box level requirement to 200 Volts per meter from 10 KHz to 40 GHz. This requirement equals or surpasses the attenuated HIRF environment over significant portions of the spectrum and implies that the aircraft must be designed to achieve and maintain this value throughout its service life. Although wires can be shielded and designed to achieve these requirements, it is a more expensive process, adds the weight of shielding and requires maintenance of the shielding integrity at all times. The very light weight and high bandwidth of fiber optics also offer the potential of eliminating the number of connections and weight savings in aircraft. For example on a one to one replacement of wire by fiber, it is estimated that fiber would weight about 1/20 the weight of wire. Current wire buses used for duplex communications in aircraft applications have a bandwidth of about 1 MHz while equivalent buses using fiber optics have a bandwidth of 20 MHz. For other applications such as video and avionics interfaces, fiber buses in the hundreds of MHz are available. Applications of fiber optic buses would then result in the reduction of wires and connections because of reduction in the number of buses needed for information transfer due to the fact that a large number of different signals can be sent across one fiber by multiplexing each signal. The Advanced Research Projects Agency (ARPA) Technology Reinvestment Project (TRP) Fly-by-Light Advanced Systems Hardware (FLASH) program addresses the development of Fly-by-Light Technology in order to apply the benefits of fiber optics to military and commercial aircraft.
Additive Manufacturing: Which DLA-Managed Legacy Parts are Potential AM Candidates
2016-07-01
william.t.veney.civ@mail.mil Mr. Scot Seitz Army/G4 717-770-4304 scot.s.seitz.civ@mail.mil Mr. Stephen Luckowski Army/RDECOM 973-724-3100...stephen.l.luckowski.civ@mail.mil Maj. Eric Kirchner Marine Corps/I&L 571-256-7105 eric.kirchner@usmc.mil Capt. Christopher Wood Marine Corps/I&L 571-256-2740
Forge.mil Home About FAQs News Resources Support Top 10 FAQs What is the Forge.mil Program? What is SoftwareForge? What is ProjectForge? Is there a Forge.mil site on SIPRNET? What is the difference between SoftwareForge and ProjectForge? What capabilities are available in the system? What are the guidelines for
New GREEN Products for the Military Aviation Maintenance Community
2012-05-01
Petroleum Base, for Preservation and Operation • MIL -H-19457 - Hydraulic Fluid, Fire-resistant, Non-neurotoxic • MIL -H- 81019 ...ENHANCEMENT STEWARDSHIP EXCELLENCE WORKFORCE DEVELOPMENT 14 New GREEN products (NAVAIR) MIL -PRF-85570...aircraft spot cleaners Mil -C-43616 • 6850-01-578-4978 type I • 6850-01-581-9413 type II • 6850-01-587-3779 type I
Systematic review of meaning in life assessment instruments.
Brandstätter, Monika; Baumann, Urs; Borasio, Gian Domenico; Fegg, Martin Johannes
2012-10-01
The construct of "meaning in life" (MiL) has raised the interest of clinicians working in psycho-oncology and end-of-life care. It has become a topic of scientific investigation where diverse assessment approaches have been applied. We present a comprehensive systematic review of existing MiL assessment instruments. Electronic searches of articles published in English peer-reviewed journals were performed in Psycinfo, Medline, Embase and Cinahl. Instruments are appraised with regard to ten measurement properties. In total, 59 nomothetic and idiographic MiL instruments were identified. Most instruments were developed in North America and meet basic psychometric criteria. They assess presence of and search for MiL, crisis and sources of MiL, meaning making, meaningful activity, MiL in the context of illness, breadth, depth, and other structural indicators. These aspects are largely consistent with existing MiL definitions. Nine out of 59 instruments included cancer populations in test development. This overview of available instruments underscores the complexity of the construct and might assist researchers to select an appropriate instrument for their research needs. Finally, it points to the need for more integrative theorizing and research on MiL. Copyright © 2012 John Wiley & Sons, Ltd.
Seo, Pill Won; Bhadra, Biswa Nath; Ahmed, Imteaz; Khan, Nazmul Abedin; Jhung, Sung Hwa
2016-10-03
Adsorption of typical pharmaceuticals and personal care products (PPCPs) (such as naproxen, ibuprofen and oxybenzone) from aqueous solutions was studied by using the highly porous metal-organic framework (MOF) MIL-101 with and without functionalization. Adsorption results showed that MIL-101s with H-donor functional groups such as -OH and -NH 2 were very effective for naproxen adsorption, despite a decrease in porosity, probably because of H-bonding between O atoms on naproxen and H atoms on the adsorbent. For this reason, MIL-101 with two functional groups capable of H-bonding (MIL-101-(OH) 2 ) exhibited remarkable adsorption capacity based on adsorbent surface area. The favorable contributions of -OH and -(OH) 2 on MIL-101 in the increased adsorption of ibuprofen and oxybenzone (especially based on porosity) confirmed again the importance of H-bonding mechanism. The adsorbent with the highest adsorption capacity, MIL-101-OH, was very competitive when compared with carbonaceous materials, mesoporous materials, and pristine MIL-101. Moreover, the MIL-101-OH could be recycled several times by simply washing with ethanol, suggesting potential application in the adsorptive removal of PPCPs from water.
NASA Astrophysics Data System (ADS)
Seo, Pill Won; Bhadra, Biswa Nath; Ahmed, Imteaz; Khan, Nazmul Abedin; Jhung, Sung Hwa
2016-10-01
Adsorption of typical pharmaceuticals and personal care products (PPCPs) (such as naproxen, ibuprofen and oxybenzone) from aqueous solutions was studied by using the highly porous metal-organic framework (MOF) MIL-101 with and without functionalization. Adsorption results showed that MIL-101s with H-donor functional groups such as -OH and -NH2 were very effective for naproxen adsorption, despite a decrease in porosity, probably because of H-bonding between O atoms on naproxen and H atoms on the adsorbent. For this reason, MIL-101 with two functional groups capable of H-bonding (MIL-101-(OH)2) exhibited remarkable adsorption capacity based on adsorbent surface area. The favorable contributions of -OH and -(OH)2 on MIL-101 in the increased adsorption of ibuprofen and oxybenzone (especially based on porosity) confirmed again the importance of H-bonding mechanism. The adsorbent with the highest adsorption capacity, MIL-101-OH, was very competitive when compared with carbonaceous materials, mesoporous materials, and pristine MIL-101. Moreover, the MIL-101-OH could be recycled several times by simply washing with ethanol, suggesting potential application in the adsorptive removal of PPCPs from water.
Seo, Pill Won; Bhadra, Biswa Nath; Ahmed, Imteaz; Khan, Nazmul Abedin; Jhung, Sung Hwa
2016-01-01
Adsorption of typical pharmaceuticals and personal care products (PPCPs) (such as naproxen, ibuprofen and oxybenzone) from aqueous solutions was studied by using the highly porous metal-organic framework (MOF) MIL-101 with and without functionalization. Adsorption results showed that MIL-101s with H-donor functional groups such as –OH and –NH2 were very effective for naproxen adsorption, despite a decrease in porosity, probably because of H-bonding between O atoms on naproxen and H atoms on the adsorbent. For this reason, MIL-101 with two functional groups capable of H-bonding (MIL-101-(OH)2) exhibited remarkable adsorption capacity based on adsorbent surface area. The favorable contributions of –OH and –(OH)2 on MIL-101 in the increased adsorption of ibuprofen and oxybenzone (especially based on porosity) confirmed again the importance of H-bonding mechanism. The adsorbent with the highest adsorption capacity, MIL-101-OH, was very competitive when compared with carbonaceous materials, mesoporous materials, and pristine MIL-101. Moreover, the MIL-101-OH could be recycled several times by simply washing with ethanol, suggesting potential application in the adsorptive removal of PPCPs from water. PMID:27695005
School Planning, Evaluation and Communication System (SPECS).
ERIC Educational Resources Information Center
Flocco, Edward C.
A comprehensive school planning tool is available from General Learning Corporation and the Center for the Advanced Study of Educational Administration at the University of Oregon. This School Planning, Evaluation and Communication System (SPECS) provides a deliverable system of training, implementation strategies and materials and technical…
Jäger, Peter; Minn, Myin Zu
2015-07-31
Specimens of the spider genera Ctenus Walckenaer, 1805 and Anahita Karsch, 1879 from Myanmar were investigated. Three species are described as new to science: Anahita popa spec. nov. (female; Mt Popa), Ctenus natmataung spec. nov. (male, female; Mt Victoria) and C. pingu spec. nov. (male, female; Mt Victoria). The female of C. cladarus Jäger, 2012 is described for the first time. Males of C. natmataung spec. nov. possess an easily breakable tip of their RTA. Two cases are reported where this part was clinging to the epigyne and a pointed appendix had penetrated the female's cuticle. This is the first such case reported within the RTA-clade. All three Ctenus spp. have very similar copulatory organs and are interpreted as a product of relatively recent speciation events. According to their elevational zonation, the driving factor for this speciation could be different climatic conditions at different elevations.
Chambers, Robert S.; Tandon, Rajan; Stavig, Mark E.
2015-07-07
In this study, to analyze the stresses and strains generated during the solidification of glass-forming materials, stress and volume relaxation must be predicted accurately. Although the modeling attributes required to depict physical aging in organic glassy thermosets strongly resemble the structural relaxation in inorganic glasses, the historical modeling approaches have been distinctly different. To determine whether a common constitutive framework can be applied to both classes of materials, the nonlinear viscoelastic simplified potential energy clock (SPEC) model, developed originally for glassy thermosets, was calibrated for the Schott 8061 inorganic glass and used to analyze a number of tests. A practicalmore » methodology for material characterization and model calibration is discussed, and the structural relaxation mechanism is interpreted in the context of SPEC model constitutive equations. SPEC predictions compared to inorganic glass data collected from thermal strain measurements and creep tests demonstrate the ability to achieve engineering accuracy and make the SPEC model feasible for engineering applications involving a much broader class of glassy materials.« less
76 FR 71315 - Endangered and Threatened Species; Take of Anadromous Fish
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-17
... the fish and would then sample them for biological information (fin tissue and scale samples). They..., measured, weighed, tissue-sampled, and checked for external marks and coded-wire tags depending on the.... Then the researchers would remove and preserve fish body tissues, otoliths, and coded wire tags (from...
Ionic liquids: solvents and sorbents in sample preparation.
Clark, Kevin D; Emaus, Miranda N; Varona, Marcelino; Bowers, Ashley N; Anderson, Jared L
2018-01-01
The applications of ionic liquids (ILs) and IL-derived sorbents are rapidly expanding. By careful selection of the cation and anion components, the physicochemical properties of ILs can be altered to meet the requirements of specific applications. Reports of IL solvents possessing high selectivity for specific analytes are numerous and continue to motivate the development of new IL-based sample preparation methods that are faster, more selective, and environmentally benign compared to conventional organic solvents. The advantages of ILs have also been exploited in solid/polymer formats in which ordinarily nonspecific sorbents are functionalized with IL moieties in order to impart selectivity for an analyte or analyte class. Furthermore, new ILs that incorporate a paramagnetic component into the IL structure, known as magnetic ionic liquids (MILs), have emerged as useful solvents for bioanalytical applications. In this rapidly changing field, this Review focuses on the applications of ILs and IL-based sorbents in sample preparation with a special emphasis on liquid phase extraction techniques using ILs and MILs, IL-based solid-phase extraction, ILs in mass spectrometry, and biological applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wire and Cable Cold Bending Test
NASA Technical Reports Server (NTRS)
Colozza, Anthony
2010-01-01
One of the factors in assessing the applicability of wire or cable on the lunar surface is its flexibility under extreme cold conditions. Existing wire specifications did not address their mechanical behavior under cold, cryogenic temperature conditions. Therefore tests were performed to provide this information. To assess this characteristic 35 different insulated wire and cable pieces were cold soaked in liquid nitrogen. The segments were then subjected to bending and the force was recorded. Any failure of the insulation or jacketing was also documented for each sample tested. The bending force tests were performed at room temperature to provide a comparison to the change in force needed to bend the samples due to the low temperature conditions. The results from the bending tests were plotted and showed how various types of insulated wire and cable responded to bending under cold conditions. These results were then used to estimate the torque needed to unroll the wire under these low temperature conditions.
NASA Astrophysics Data System (ADS)
Li, L.; Sadofsky, S. J.; Bebout, G. E.
2003-12-01
We are investigating the N and C contents and isotope ratios in subducting sediment sections in the two MARGINS Subduction Factory focus sites, the Izu-Bonin (IB) and Central America (CA) convergent margins (using samples obtained on DSDP/ODP Legs 125, 170, 185, and 205). The sediments from IB (Site 1149, and Leg 129) contain 5 to 661 ppm N with δ 15NAir values of +2.5 to +8.2 per mil (weighted average +4.6 per mil). Reduced-C concentrations range from 0.02 to 0.35% with δ 13CPDB values from -28.1 to -21.7 per mil. Calcite in carbonate-rich layers has δ 13C of +1.7 to +2.8 per mil and δ 18OVSMOW of +28.5 to +29.7 per mil. In comparison with IB, the CA sediment section (Site 1039) has far higher N content (663 to 2380 ppm N with δ 15N of +3.9 to +7.1 per mil; weighted average +5.6 per mil). Calcite in Site 1039 carbonate-rich layers hasδ 13C of +0.1 to +3.0 per mil and δ 18O of +29.9 to +32.1 per mil. At Site 1149, down-section decrease in N content, accompanied by decrease in δ 15N and C/N, is thought to reflect diagenesis, whereas at Site 1039, down-section decrease in N content (near 2000 ppm at surface, near 1000 ppm at 150 km) occurs without an obvious shift in δ 15N (reduced C data not yet available). Based on the C-N concentration data we've obtained, sediment C-N input fluxes are estimated at, for the IB margin, 2.5x106 g/km.year for N, 1.7x107 g/km.year for reduced C, and 9.2x108 g/km.year for oxidized C. For the CA margin, we estimate input fluxes of 8.9x106 g/km.year for N, and 1.3x109 g/km.year for oxidized C (work on reduced C is underway). Our input fluxes for C and N differ significantly from previously published input fluxes for the two margins based on estimated subducting sediment C-N concentrations, but errors are large. For the CA margin, the sediment-only N input flux of 9.8x109 g/year (for the entire 1100 km trench length), based on our results for Site 1039, can be compared with the arc volcanic output flux of 8.1x109 g/year of Fischer et al. (2002, Science; N input flux of 6.4x109 g/year estimated by those authors), indicating the incomplete return of subducted N to the surface in arcs. The magnitude of the N input flux in altered oceanic crust remains unknown (work on AOC N-δ 15N is underway) but should also be considered in such comparisons. All estimates of this type assume uniformity in the incoming sediment section along-strike in active trenches (known not to be the case). Shifts from δ 15N values measured for the two sediment sections to values near +7 per mil for the deeply subducted sediment component as suggested by studies of volcanic gases (e.g., Fischer et al., 2002; Hilton et al., 2002) could be accomplished by moderate loss of isotopically light N during metamorphic devolatilization across forearcs.
Magnetic ionic liquids in analytical chemistry: A review.
Clark, Kevin D; Nacham, Omprakash; Purslow, Jeffrey A; Pierson, Stephen A; Anderson, Jared L
2016-08-31
Magnetic ionic liquids (MILs) have recently generated a cascade of innovative applications in numerous areas of analytical chemistry. By incorporating a paramagnetic component within the cation or anion, MILs exhibit a strong response toward external magnetic fields. Careful design of the MIL structure has yielded magnetoactive compounds with unique physicochemical properties including high magnetic moments, enhanced hydrophobicity, and the ability to solvate a broad range of molecules. The structural tunability and paramagnetic properties of MILs have enabled magnet-based technologies that can easily be added to the analytical method workflow, complement needed extraction requirements, or target specific analytes. This review highlights the application of MILs in analytical chemistry and examines the important structural features of MILs that largely influence their physicochemical and magnetic properties. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Cataldo, Giuseppe; Moseley, S. H.; Wollack, E.; Hsieh, W.; Huang, W.; Stevenson, T.
2013-06-01
Micro-Spec (µ-Spec) is a high-sensitivity direct-detection spectrometer operating in the far-infrared and submillimeter regime. When combined with a cryogenic telescope, it provides an enabling technology for studying the epoch of reionization and initial galaxy formation. As a direct-detection spectrometer, µ-Spec can provide high sensitivity under the low background conditions provided by cryogenic telescopes such as the space infrared telescope for cosmology and astrophysics SPICA. The µ-Spec modules use low-loss superconducting microstrip transmission lines implemented on a single 4-inch-diameter wafer. Such a dramatic size reduction is enabled by the use of silicon, a material with an index of refraction about three times that of vacuum, which thus allows the microstrip lines to be one third their vacuum length. Using a large number of modules as well as reducing the negative effects of stray light also contributes positively to the enhanced sensitivity of such an instrument. µ-Spec can be compared to a grating spectrometer, in which the phase retardation generated by the reflection from the grating grooves is instead produced by propagation through transmission lines of different length. The µ-Spec optical design is based on the stigmatization and minimization of the light path function in a two-dimensional diffractive region. The power collected through a broadband antenna is progressively divided by binary microstrip power dividers. The position of the radiators is selected to provide zero phase errors at two stigmatic points, and a third stigmatic point is generated by introducing a differential phase shift in each radiator. To optimize the overall efficiency of the instrument, the emitters are directed to the center of the focal surface. A point design was developed for initial demonstration. Because of losses to other diffraction orders, the efficiency of the design presented is about 30%. Design variations on this implementation are illustrated which can lead to near-unit efficiency and will be the basis of future instruments. Measurements are being conducted to validate the designs.
Advanced Combat Helmet Technical Assessment
2013-05-29
Lastly, we assessed the participation of various stakeholders and industry experts such as active ACH manufacturers and test facilities. Findings... industrially accepted American National Standards Institute (ANSI Z1.4-2008, Sampling Visit us on the web at www.dodig.mil Results in Brief Advanced...statistically principled approach and the lot acceptance test protocol adopts a widely established and industrially accepted sampling procedure. We
A preliminary assessment of sources of nitrate in springwaters, Suwannee River basin, Florida
Katz, B.G.; Hornsby, H.D.
1998-01-01
A cooperative study between the Suwannee River Water Management District (SRWMD) and the U.S. Geological Survey (USGS) is evaluating sources of nitrate in water from selected springs and zones in the Upper Floridan aquifer in the Suwannee River Basin. A multi-tracer approach, which consists of the analysis of water samples for naturally occurring chemical and isotopic indicators, is being used to better understand sources and chronology of nitrate contamination in the middle Suwannee River region. In July and August 1997, water samples were collected and analyzed from six springs and two wells for major ions, nutrients, and dissolved organic carbon. These water samples also were analyzed for environmental isotopes [18O/16O, D/H, 13C/12C, 15N/14N] to determine sources of water and nitrate. Chlorofluorocarbons (CCl3F, CCl2F2, and C2Cl3F3) and tritium (3H) were analyzed to assess the apparent ages (residence time) of springwaters and water from the Upper Floridan aquifer. Delta 15N-NO3 values in water from the six springs range from 3.94 per mil (Little River Springs) to 8.39 per mil (Lafayette Blue Spring). The range of values indicates that nitrate in the sampled springwaters most likely originates from a mixture of inorganic (fertilizers) and organic (animal wastes) sources, although the higher delta 15N-NO3 value for Lafayette Blue Spring indicates that an organic source of nitrogen is likely at this site. Water samples from the two wells sampled in Lafayette County have high delta 15N-NO3 values of 10.98 and 12.1 per mil, indicating the likelihood of an organic source of nitrate. These two wells are located near dairy and poultry farms, where leachate from animal wastes may contribute nitrate to ground water. Based on analysis of chlorofluorocarbons in ground water, the mean residence time of water in springs ranges from about 12 to 25 years. Chlorofluorocarbons-modeled recharge dates for water samples from the two shallow zones in the Upper Floridan aquifer range from 1985 to 1989.
2013-04-01
III. Characterization of Polymorphic States in Energetic Samples of 1,3,5-Trinitro-1,3,5- Triazine ( RDX ) Fabricated Using Drop-on-Demand Inkjet...Asher, S. A. Deep-Ultraviolet Resonance Raman Excitation Profiles of NH4NO3, PETN, TNT, HMX , and RDX . Appl. Spec. 2012, 66 (9), 1013–1021. 19. Izake...L. A. The IV-III Polymorphic Phase- transition in Smmonium Nitrate – A Unique Example of Solvent Mediation. J. Phys. D. Apply. Phys. 1991, 24 (2
Food-web structure of seep sediment macrobenthos from the Gulf of Mexico
Demopoulos, Amanda W.J.; Gualtieri, Daniel; Kovacs, Kaitlin
2010-01-01
The slope environment of the Gulf of Mexico (GOM) supports dense communities of seep megafaunal invertebrates that rely on endosymbiotic bacteria for nutrition. Seep sediments also contain smaller macrofaunal invertebrates whose nutritional pathways are not well understood. Using stable-isotope analysis, we investigate the utilization of chemosynthetically fixed and methane-derived organic matter by macrofauna. Biological sampling was conducted in three lower-slope GOM seep environs: Green Canyon (GC852, 1428 m), Atwater Valley (AT340, 2230 m), and Alaminos Canyon (AC601, 2384 m). Infaunal delta13C and delta15N exhibited a broad range of values; most infauna appeared to be heterotrophic, although several taxa had very light delta15N and delta13C values, indicating possible reliance on chemoautotrophic symbioses. The lightest delta13C and delta15N values were observed in nematodes (delta13C=-54.6 + or - 0.1 per mil, delta15N=-6.1 + or - 0.2 per mil) and one gastropod (delta13C=-54.1 per mil, delta15N=-1.1 per mil) from Green Canyon. Mixing-model results indicated that sulfur-oxidizing Beggiatoa may be an important food source for seep infauna; the rate of utilization ranged from 60% to 100% at Green Canyon and Atwater Valley. The overall range in isotope values was similar across the three sites, suggesting that biogeochemical processes may be very similar in these geographically distinct areas.
Alqadami, Ayoub Abdullah; Naushad, Mu; Alothman, Zeid Abdullah; Ghfar, Ayman A
2017-10-18
The combination of magnetic nanoparticles and metal-organic frameworks (MOFs) has demonstrated their prospective for pollutant sequestration. In this work, a magnetic metal-organic framework nanocomposite (Fe 3 O 4 @AMCA-MIL53(Al) was prepared and used for the removal of U(VI) and Th(IV) metal ions from aqueous environment. Fe 3 O 4 @AMCA-MIL53(Al) nanocomposite was characterized by TGA, FTIR, SEM-EDX, XRD, HRTEM, BET, VSM (vibrating sample magnetometry), and XPS analyses. A batch technique was applied for the removal of the aforesaid metal ions using Fe 3 O 4 @AMCA-MIL53(Al) at different operating parameters. The isotherm and kinetic data were accurately described by the Langmuir and pseudo-second-order models. The adsorption capacity was calculated to be 227.3 and 285.7 mg/g for U(VI) and Th(IV), respectively, by fitting the equilibrium data to the Langmuir model. The kinetic studies demonstrated that the equilibrium time was 90 min for each metal ion. Various thermodynamic parameters were evaluated which indicated the endothermic and spontaneous nature of adsorption. The collected outcomes showed that Fe 3 O 4 @AMCA-MIL53(Al) was a good material for the exclusion of these metal ions from aqueous medium. The adsorbed metals were easily recovered by desorption in 0.01 M HCl. The excellent adsorption capacity and the response to the magnetic field made this novel material an auspicious candidate for environmental remediation technologies.
Ye, Jia; Gao, Yong
2012-01-01
Rotary instruments made of a new nickel-titanium (NiTi) alloy (M-Wire) have shown improved cyclic fatigue resistance and mechanical properties compared with those made of conventional superelastic NiTi wires. The objective of this study was to characterize microstructural changes of M-Wire throughout the cyclic fatigue process under controlled strain amplitude. The average fatigue life was calculated from 30 M-Wire samples that were subjected to a strain-controlled (≈ 4%) rotating bend fatigue test at room temperature and rotational speed of 300 rpm. Microstructural evolution of M-Wire has been investigated by different metallurgical characterization techniques, including differential scanning calorimetry, Vickers microhardness, and transmission electron microscopy at 4 different stages (as-received state, 30%, 60%, and 90% of average fatigue life). During rotating bend fatigue test, no statistically significant difference (P > .05) was found on austenite finish temperatures between as-received M-Wire and fatigued samples. However, significant differences (P < .05) were observed on Vickers microhardness for samples with 60% and 90% fatigue life compared with as-received and 30% fatigue life. Coincidentally, substantial growth of martensite grains and martensite twins was observed in microstructure under transmission electron microscopy after 60% fatigue life. The results of the present study suggested that endodontic instruments manufactured with M-Wire are expected to have higher strength and wear resistance than similar instruments made of conventional superelastic NiTi wires because of its unique nano-crystalline martensitic microstructure. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Ag{sup II} doped MIL-101 and its adsorption of iodine with high speed in solution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mao, Ping; Qi, Bingbing; Liu, Ying
In order to improve the adsorption speed of iodine from water, MIL-101 with extra-large specific surface area (3054 m{sup 2}/g) was chosen as a base material, and then, Ag was doped into MIL-101 to enhance its adsorption capacity through an incipient-wetness impregnation method. With the characterization of SEM-EDS, TEM, XRD, XPS, TGA, IR, and BET techniques, the resulting Ag was identified to be stay in the framework of MIL-101 stably in the form of Ag{sup II} (generally, Ag{sup II} cation is not stable). However, after the adsorption of I{sup −} anions, Ag{sup II} stay in the cages of MIL-101 inmore » the form of AgI/AgI{sub 3}. It is important to note that, all adsorbents show high adsorption speed of iodine in solution. The equilibrium adsorption time of the adsorbents were acquired by only a few minutes, which can be attributed to its large BET surface area. An interesting note is that, when the doping amount of Ag is less than 9%, the iodine anions adsorption capacity of Ag@MIL-101 is greater than its theoretical adsorption capacity. It shows that both physical adsorption and chemical adsorption are existed in the adsorption process. This study hopefully leads to a new and highly efficient Ag-based adsorbent for iodide adsorb from solutions. - Graphical abstract: Ag{sup II} stay in the framework of MIL-101 stably because of F{sup -}, after the adsorption of I{sup -} anions, Ag{sup I}I /Ag{sup I}I{sub 3} stay in the cages of MIL-101. The equilibrium adsorption time of Ag@MIL-101 were acquired by only a few minutes. - Highlights: • Ag{sup II} was doped into MIL-101 by an incipient-wetness impregnation method. • Both physical adsorption and chemical adsorption are verified in the adsorption process. • Ag@MIL-101 exhibits high adsorption speed and adsorption capacity. • Ag@MIL-101 can be effectively applied to the removal of radioactive iodide anions from water in acidic and neutral medium.« less
FIELD VERIFICATION OF LINERS FROM SANITARY LANDFILLS
Liner specimens from three existing landfill sites were collected and examined to determine the changes in their physical properties over time and to validate data being developed through laboratory research. Samples examined included a 15-mil PVC liner from a sludge lagoon in Ne...
Pool boiling of water on nano-structured micro wires at sub-atmospheric conditions
NASA Astrophysics Data System (ADS)
Arya, Mahendra; Khandekar, Sameer; Pratap, Dheeraj; Ramakrishna, S. Anantha
2016-09-01
Past decades have seen active research in enhancement of boiling heat transfer by surface modifications. Favorable surface modifications are expected to enhance boiling efficiency. Several interrelated mechanisms such as capillarity, surface energy alteration, wettability, cavity geometry, wetting transitions, geometrical features of surface morphology, etc., are responsible for change in the boiling behavior of modified surfaces. Not much work is available on pool boiling at low pressures on microscale/nanoscale geometries; low pressure boiling is attractive in many applications wherein low operating temperatures are desired for a particular working fluid. In this background, an experimental setup was designed and developed to investigate the pool boiling performance of water on (a) plain aluminum micro wire (99.999 % pure) and, (b) nano-porous alumina structured aluminum micro wire, both having diameter of 250 µm, under sub-atmospheric pressure. Nano-structuring on the plain wire surface was achieved via anodization. Two samples, A and B of anodized wires, differing by the degree of anodization were tested. The heater length scale (wire diameter) was much smaller than the capillary length scale. Pool boiling characteristics of water were investigated at three different sub-atmospheric pressures of 73, 123 and 199 mbar (corresponding to T sat = 40, 50 and 60 °C). First, the boiling characteristics of plain wire were measured. It was noticed that at sub-atmospheric pressures, boiling heat transfer performance for plain wire was quite low due to the increased bubble sizes and low nucleation site density. Subsequently, boiling performance of nano-structured wires (both Sample A and Sample B) was compared with plain wire and it was noted that boiling heat transfer for the former was considerably enhanced as compared to the plain wire. This enhancement is attributed to increased nucleation site density, change in wettability and possibly due to enhanced pore scale evaporation. A preliminary estimation of the bubble growth rates, measured by high speed videography, was undertaken and compared with classical bubble growth rate correlations. It was observed that the average bubble departure sizes on Sample B were larger as compared to plain wire, due to larger surface forces holding the bubble before departure. Bubble condensation in the thermal boundary layer was also captured.
Ectoderm gene activation in sea urchin embryos mediated by the CCAAT-binding factor.
Li, Xiaotao; Bhattacharya, Chitralekha; Dayal, Sandeep; Maity, Sankar; Klein, William H
2002-05-01
Transcriptional enhancers are short stretches of DNA that function to achieve highly specific patterns of gene expression. To identify the mechanisms by which enhancers achieve their specificity, we made use of an enhancer from the aboral ectoderm-specific spec2a gene of the sea urchin Strongylocentrotus purpuratus. The spec2a enhancer contains five cis-regulatory elements within 78 base pairs that interact with five distinct DNA-binding proteins to confer aboral ectoderm expression. Here, we present an analysis of the sea urchin CCAAT binding factor (CBF), which binds to a CCAAT motif within the spec2a enhancer. S. purpuratus CBF and SpOtx, a ubiquitously expressed factor, act together at closely placed cis-regulatory elements to mediate spec2a transcription in the ectoderm. SpCBF was the sole factor that bound to the spec2a CCAAT element, and two of the three subunits that make up the CBF holoprotein were cloned and shown to have high sequence conservation with their vertebrate orthologs. Based on its involvement in the regulation of several other sea urchin genes, SpCBF appears to be a major transcription factor in the sea urchin embryo for positive regulation of ectoderm gene expression. In addition to its role in vertebrate cell growth and proliferation, our results indicate that CBF also functions at the early stages of germ layer formation, namely ectoderm differentiation.
Use of reinforced inorganic cement materials for spark wire and drift chamber wire frames
NASA Technical Reports Server (NTRS)
1987-01-01
The results of a survey, materials test, and analysis study directed toward the development of an inorganic glass-fiber reinforced cement material for use in the construction of space qualified spark wire frames and drift chamber frames are presented. The purpose for this research was to evaluate the feasibility of using glass fiber reinforced cement (GFRC) for large dimensioned structural frames for supporting a number of precisely located spark wires in multiple planes. A survey of the current state of the art in fiber reinforced cement materials was made; material sample mixes were made and tested to determine their laboratory performances. Tests conducted on sample materials showed that compressive and flexural strengths of this material could approach values which would enable fabrication of structural spark wire frames.
NASA Astrophysics Data System (ADS)
Luecke, Andreas; Wissel, Holger; Mayr*, Christoph; Oehlerich, Markus; Ohlendorf, Christian; Zolitschka, Bernd; Pasado Science Team
2010-05-01
The ICDP project PASADO aims to develop a detailed paleoclimatic record for the southern part of the South American continent from sediments of Laguna Potrok Aike (51°58'S, 70°23'W), situated in the Patagonian steppe east of the Andean cordillera and north of the Street of Magellan. The precursor project SALSA recovered the Holocene and Late Glacial sediment infill of Laguna Potrok Aike and developed the environmental history of the semi-arid Patagonian steppe by a consequent interdisciplinary multi-proxy approach (e.g. Haberzettl et al., 2007). From September to November 2008 the ICDP deep drilling took place and successfully recovered in total 510 m of sediments from two sites resulting in a composite depth of 106 m for the selected main study Site 2. A preliminary age model places the record within the last 50.000 years. During the drilling campaign, the core catcher content of each drilled core run (3 m) was taken as separate sample to be shared and distributed between involved laboratories long before the main sampling party. A total of 70 core catcher samples describe the sediments of Site 2 and will form the base for more detailed investigations on the palaeoclimatic history of Patagonia. We here report on the organic carbon and nitrogen isotope composition of bulk sediment and plant debris of the core catcher samples. Similar investigations were performed for Holocene and Late Glacial sediments of Laguna Potrok Aike revealing insights into the organic matter dynamics of the lake and its catchment as well as into climatically induced hydrological variations with related lake level fluctuations (Mayr et al., 2009). The carbon and nitrogen content of the core catcher fine sediment fraction (<200 µm) is low to very low (around 1 % and 0.1 %, respectively) and requires particular attention in isotope analysis. The carbon isotope composition shows comparably little variation around a value of -26.0 per mil. The positive values of the Holocene and the Late Glacial (up to 22.0 per mil) are only sporadically reached down core. Compared to this, separated moss debris is remarkably 13C depleted with a minimum at 31.5 per mil. The nitrogen isotope ratios of glacial Laguna Potrok Aike sediments are lower (2.5 per mil) than those of the younger part of the record. The core catcher samples indicate several oscillations between 0.5 and 3.5 per mil. Data suggest a correlation between nitrogen isotopes and C/N ratios, but no linear relation between carbon isotopes and carbon content and an only weak relationship between carbon and nitrogen isotopes. Increasing nitrogen isotope values from 8000 cm downwards could probably be related to changed environmental conditions of Marine Isotope Stage 3 (MIS 3) compared to Marine Isotope Stage 2 (MIS 2). This will be further evaluated with higher resolution from the composite profile including a detailed study of discrete plant debris layers. References Haberzettl, T. et al. (2007). Lateglacial and Holocene wet-dry cycles in southern Patagonia: chronology, sedimentology and geochemistry of a lacustrine record from Laguna Potrok Aike, Argentina. The Holocene, 17: 297-310. Mayr, C. et al. (2009). Isotopic and geochemical fingerprints of environmental changes during the last 16,000 years on lacustrine organic matter from Laguna Potrok Aike (southern Patagonia, Argentina). Journal of Paleolimnology, 42: 81-102.
Nitrogen isotopic signatures in the Acapulco meteorite
NASA Technical Reports Server (NTRS)
Sturgeon, G.; Marti, K.
1991-01-01
N isotopic abundances are reported for a bulk sample of the unique meteorite Acapulco. Although the mineral chemistry indicates a high degree of recrystallization under redox conditions between those of H and E chondrites (Palme et al., 1981), the presence of two distinct N isotopic signatures shows that the carriers of these N components were not equilibrated. In stepwise pyrolysis, the larger (65 percent) N component is released mostly below 1000 C and reveals a signature of delta(N-15) = 8.9 + or - 1.2 per mil, which is within the range observed in chondrites. A second 'light' component appears above 1000 C and has a signature of delta(N-15) less than or equal to -110.5 + or - 4.0 per mil (uncorrected for spallation N-15).
Qualitative Collection Analysis: The Conspectus Methodology. SPEC Kit 151.
ERIC Educational Resources Information Center
Jakubs, Deborah
The introduction to this Systems and Procedures Exchange Center (SPEC) kit explains the Conspectus method, which was developed in 1980 by the Research Libraries Group (RLG) as a means of systematically and qualitatively evaluating large library collections. The discussion considers advantages and disadvantages of this tool, which evaluates past…
Serials Control and Deselection Projects. SPEC Kit 147.
ERIC Educational Resources Information Center
Association of Research Libraries, Washington, DC. Office of Management Studies.
This Systems and Procedures Exchange Center (SPEC) Kit on serials control and deselection projects provides a timely review of the efforts of research libraries to control the increasing costs of serial subscriptions. This kit contains documents from 13 libraries: University of California at Los Angeles and Riverside; Universities of Florida,…
Electronic Reference Service. SPEC Kit 251.
ERIC Educational Resources Information Center
Goetsch, Lori, Comp.
1999-01-01
The goals of this SPEC Kit were to report on the extent to which ARL (Association of Research Libraries) libraries provide electronic reference services and to offer a snapshot of the types of users reached, questions received, policies established, data-gathering techniques utilized, and innovations implemented. The first section of the kit…
Numeric Data Products and Services. SPEC Kit.
ERIC Educational Resources Information Center
Cook, Michael N., Comp.; Hernandez, John J., Comp.; Nicholson, Shawn, Comp.
2001-01-01
This SPEC (Systems and Procedures Exchange Center) Kit presents the results of a survey of Association of Research Libraries (ARL) member libraries. The survey addressed the following questions about numeric data (i.e., any information resource, print or non-print, with considerable numeric content) in academic libraries: (1) What relationships…
Planning Systems. SPEC Kit 13.
ERIC Educational Resources Information Center
Association of Research Libraries, Washington, DC. Office of Management Studies.
This kit on planning systems updates a 1974 Management Studies Office Systems and Procedures Exchange Center (SPEC) kit in which developments in planning activities among Association of Research Libraries (ARL) were reviewed. At the time of the original study, in 1972, planning techniques and systems were a subject of much interest because rising…
Managing Corporate Annual Reports. SPEC Kit 258.
ERIC Educational Resources Information Center
O'Connor, Lisa, Comp.
2000-01-01
The purpose of the survey for this SPEC (Systems and Procedures Exchange Center) Kit was to assess the current print corporate annual report collection practices of ARL (Association of Research Libraries) libraries, describe the effects of these collections, and recommend best practices for preserving these significant historical documents. The…
SPECS 2. Component Two: Program Budgeting and Cost Accounting.
ERIC Educational Resources Information Center
DuVall, Lloyd A.
The School Planning, Evaluation, and Communication System (SPECS) is an overall design for districtwide program assessment and development. It is both a way of interrelating planning and evaluation of individual programs and a way of comparing the outcomes of all district programs with the district's community-defined educational goals. Component…
Scholarly Information Centers in ARL Libraries. SPEC Kit 175.
ERIC Educational Resources Information Center
Allen, Nancy, Comp.; Godden, Irene, Comp.
Noting that the rapid evolution of telecommunications technology, the relentless advancement of computing capabilities, and the seemingly endless proliferation of electronic data have had a profound impact on research libraries, this Systems and Procedures Exchange Center (SPEC) kit explores the extent to which these technologies have come…
Library Reorganization & Restructuring. SPEC Kit 215.
ERIC Educational Resources Information Center
Eustis, Joanne D., Comp.; Kenney, Donald J. Comp.
As the entity traditionally responsible for serving the information needs of the university, research libraries have little choice but to change dramatically in the next 25 years. This SPEC Survey on library reorganization seeks to understand how librarians have sought to meet this challenge through the redesigning of their organization.…
Networked Information Resources. SPEC Kit 253.
ERIC Educational Resources Information Center
Bleiler, Richard, Comp.; Plum, Terry, Comp.
1999-01-01
This SPEC Kit, published six times per year, examines how Association of Research Libraries (ARL) libraries have structured themselves to identify networked information resources in the market, to evaluate them for purchase, to make purchasing decisions, to publicize them, and to assess their continued utility. In the summer of 1999, the survey…
Role of Libraries in Distance Education. SPEC Kit 216.
ERIC Educational Resources Information Center
Snyder, Carolyn A., Comp.; And Others
The Systems and Procedures Exchange Center (SPEC) surveyed 119 Association of Research Libraries (ARL) members to gather information about current distance education and distance learning initiatives in ARL libraries. The objectives of the survey were to: (1) identify libraries involved in distance education activities and determine the extent or…
Blast Coating of Superelastic NiTi Wire with PTFE to Enhance Wear Properties
NASA Astrophysics Data System (ADS)
Dunne, Conor F.; Roche, Kevin; Twomey, Barry; Hodgson, Darel; Stanton, Kenneth T.
2015-03-01
This work investigates the deposition of polytetrafluoroethylene (PTFE) onto a superelastic NiTi wire using an ambient temperature-coating technique known as CoBlast. The process utilises a stream of abrasive (Al2O3) and a coating medium (PTFE) sprayed simultaneously at the surface of the substrate. Superelastic NiTi wire is used in guidewire applications, and PTFE coatings are commonly applied to reduce damage to vessel walls during insertion and removal, and to aid in accurate positioning by minimising the force required to advance, retract or rotate the wire. The CoBlast coated wires were compared to wire treated with PTFE only. The coated samples were examined using variety of techniques: X-ray diffraction (XRD), microscopy, surface roughness, wear testing and flexural tests. The CoBlast coated samples had an adherent coating with a significant resistance to wear compared to the samples coated with PTFE only. The XRD revealed that the process gave rise to a stress-induced martensite phase in the NiTi which may enhance mechanical properties. The study indicates that the CoBlast process can be used to deposit thin adherent coatings of PTFE onto the surface of superelastic NiTi.
Defense AT and L. Volume 44, Number 3
2015-06-01
CommunityBrowser.aspx?id=527436 Product Support Key References https://acc.dau.mil/productsupport CLL 011 Performance-Based Life Cycle Product Support (PBL...http://icatalog.dau.mil/onlinecatalog/courses.aspx?crs_id=269 CLL 031 PBL Contracting Strategies http://icatalog.dau.mil/onlinecatalog/courses.aspx...CommunityBrowser.aspx?id=527436 Product Support Key References https://acc.dau.mil/productsupport CLL 011 Performance-Based Life Cycle Product Support (PBL) http
Liu, Tong; Hu, John; Zuo, Yuhu; Jin, Yazhong; Hou, Jumei
2016-04-01
Deep sequencing of small RNAs is a useful tool to identify novel small RNAs that may be involved in fungal growth and pathogenesis. In this study, we used HiSeq deep sequencing to identify 747,487 unique small RNAs from Curvularia lunata. Among these small RNAs were 1012 microRNA-like RNAs (milRNAs), which are similar to other known microRNAs, and 48 potential novel milRNAs without homologs in other organisms have been identified using the miRBase© database. We used quantitative PCR to analyze the expression of four of these milRNAs from C. lunata at different developmental stages. The analysis revealed several changes associated with germinating conidia and mycelial growth, suggesting that these milRNAs may play a role in pathogen infection and mycelial growth. A total of 8334 target mRNAs for the 1012 milRNAs that were identified, and 256 target mRNAs for the 48 novel milRNAs were predicted by computational analysis. These target mRNAs of milRNAs were also performed by gene ontology and Kyoto Encyclopedia of Genes and Genomes pathway analysis. To our knowledge, this study is the first report of C. lunata's milRNA profiles. This information will provide a better understanding of pathogen development and infection mechanism.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zadehahmadi, Farnaz; Tangestaninejad, Shahram, E-mail: stanges@sci.ui.ac.ir; Moghadam, Majid, E-mail: moghadamm@sci.ui.ac.ir
2014-10-15
In the present work, chloromethylated MIL-101(Cr) modified with imidazole, Im-MIL-101, was applied as a support for immobilizing of tetraphenylporphyrinatomangenese(III) chloride. The imidazole-bound MIL-101, Im-MIL-101, not only used as support for immobilization of manganese porphyrin but also applied as a heterogeneous axial base. The Mn(TPP)Cl@Im-MIL-101 catalyst was characterized by UV–vis, FT-IR, X-ray diffraction (XRD), N{sub 2} adsorption, field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray (EDX), elemental analysis and inductively coupled plasma (ICP) methods. The catalytic activity of this new catalytic system was investigated in the alkene epoxidation and alkane hydroxylation using NaIO{sub 4} as an oxidant in CH{sub 3}CN/H{submore » 2}O at room temperature. This heterogeneous catalyst is highly efficient, stable and reusable in the oxidation of hydrocarbons. - Highlights: • MIL-101 was modified by covalent post synthetic modification. • Mn(TPP)Cl was anchored to imidazole modified MIL-101 by covalent attachment. • A heterogeneous catalyst was prepared. • The catalyst was used for epoxidation of alkenes and hydroxylation of alkanes. • The catalyst was reusable.« less
Effects of intraoral aging on surface properties of coated nickel-titanium archwires.
Rongo, Roberto; Ametrano, Gianluca; Gloria, Antonio; Spagnuolo, Gianrico; Galeotti, Angela; Paduano, Sergio; Valletta, Rosa; D'Antò, Vincenzo
2014-07-01
To evaluate the effects of intraoral aging on surface properties of esthetic and conventional nickel-titanium (NiTi) archwires. Five NiTi wires were considered for this study (Sentalloy, Sentalloy High Aesthetic, Superelastic Titanium Memory Wire, Esthetic Superelastic Titanium Memory Wire, and EverWhite). For each type of wire, four samples were analyzed as received and after 1 month of clinical use by an atomic force microscope (AFM) and a scanning electronic microscope (SEM). To evaluate sliding resistance, two stainless steel plates with three metallic or three monocrystalline brackets, bonded in passive configuration, were manufactured; four as-received and retrieved samples for every wire were pulled five times at 5 mm/min for 1 minute by means of an Instron 5566, recording the greatest friction value (N). Data were analyzed by one-way analysis of variance and by Student's t-test. After clinical use, surface roughness increased considerably. The SEM images showed homogeneity for the as-received control wires; however, after clinical use esthetic wires exhibited a heterogeneous surface with craters and bumps. The lowest levels of friction were observed with the as-received Superelastic Titanium Memory Wire on metallic brackets. When tested on ceramic brackets, all the wires exhibited an increase in friction (t-test; P < .05). Furthermore, all the wires, except Sentalloy, showed a statistically significant increase in friction between the as-received and retrieved groups (t-test; P < .05). Clinical use of the orthodontic wires increases their surface roughness and the level of friction.
Uma, Kasimayan; Pan, Guan-Ting; Yang, Thomas C-K
2017-06-02
Abst r act: Metal organic framework (MOF) of MIL-101(Cr)-Silica (SiO₂) composites with highly mesoporous and uniform dispersions were synthesized by a microwave-assisted hydrothermal method followed by the sol-gel technique. Water vapor adsorption experiments were conducted on the MIL-101(Cr)-SiO₂ composites for industrial adsorption chiller applications. The effects of MIL-101(Cr)-SiO₂ mixing ratios (ranging from 0% to 52%), the surface area and amount of Lewis and Brønsted sites were comprehensively determined through water vapor adsorption experiments and the adsorption mechanism is also explained. The BET and Langmuir results indicate that the adsorption isotherms associated with the various MIL-101(Cr)-SiO₂ ratios demonstrated Type I and IV adsorption behavior, due to the mesoporous structure of the MIL-101(Cr)-SiO₂. It was observed that the increase in the amount of Lewis and Brønsted sites on the MIL-101(Cr)-SiO₂ composites significantly improves the water vapor adsorption efficiency, for greater stability during the water vapor adsorption experiments.
Amplifier Module for 260-GHz Band Using Quartz Waveguide Transitions
NASA Technical Reports Server (NTRS)
Padmanabhan, Sharmila; Fung, King Man; Kangaslahti, Pekka P.; Peralta, Alejandro; Soria, Mary M.; Pukala, David M.; Sin, Seth; Samoska, Lorene A.; Sarkozy, Stephen; Lai, Richard
2012-01-01
Packaging of MMIC LNA (monolithic microwave integrated circuit low-noise amplifier) chips at frequencies over 200 GHz has always been problematic due to the high loss in the transition between the MMIC chip and the waveguide medium in which the chip will typically be used. In addition, above 200 GHz, wire-bond inductance between the LNA and the waveguide can severely limit the RF matching and bandwidth of the final waveguide amplifier module. This work resulted in the development of a low-loss quartz waveguide transition that includes a capacitive transmission line between the MMIC and the waveguide probe element. This capacitive transmission line tunes out the wirebond inductance (where the wire-bond is required to bond between the MMIC and the probe element). This inductance can severely limit the RF matching and bandwidth of the final waveguide amplifier module. The amplifier module consists of a quartz E-plane waveguide probe transition, a short capacitive tuning element, a short wire-bond to the MMIC, and the MMIC LNA. The output structure is similar, with a short wire-bond at the output of the MMIC, a quartz E-plane waveguide probe transition, and the output waveguide. The quartz probe element is made of 3-mil quartz, which is the thinnest commercially available material. The waveguide band used is WR4, from 170 to 260 GHz. This new transition and block design is an improvement over prior art because it provides for better RF matching, and will likely yield lower loss and better noise figure. The development of high-performance, low-noise amplifiers in the 180-to- 700-GHz range has applications for future earth science and planetary instruments with low power and volume, and astrophysics array instruments for molecular spectroscopy. This frequency band, while suitable for homeland security and commercial applications (such as millimeter-wave imaging, hidden weapons detection, crowd scanning, airport security, and communications), also has applications to future NASA missions. The Global Atmospheric Composition Mission (GACM) in the NRC Decadel Survey will need low-noise amplifiers with extremely low noise temperatures, either at room temperature or for cryogenic applications, for atmospheric remote sensing.
Li, Na; Wu, Lijie; Nian, Li; Song, Ying; Lei, Lei; Yang, Xiao; Wang, Kun; Wang, Zhibing; Zhang, Liyuan; Zhang, Hanqi; Yu, Aimin; Zhang, Ziwei
2015-09-01
Non-polar solvent dynamic microwave assisted extraction was firstly applied to the treatment of high-fat soybean samples. In the dispersive micro-solid-phase extraction (D-µ-SPE), the herbicides in the high-fat extract were directly adsorbed on metal-organic frameworks MIL-101(Cr). The effects of several experimental parameters, including extraction solvent, microwave absorption medium, microwave power, volume and flow rate of extraction solvent, amount of MIL-101(Cr), and D-µ-SPE time, were investigated. At the optimal conditions, the limits of detection for the herbicides ranged from 1.56 to 2.00 μg kg(-1). The relative recoveries of the herbicides were in the range of 91.1-106.7%, and relative standard deviations were equal to or lower than 6.7%. The present method was simple, rapid and effective. A large amount of fat was also removed. This method was demonstrated to be suitable for treatment of high-fat samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Wiersum, Andrew D; Giovannangeli, Christophe; Vincent, Dominique; Bloch, Emily; Reinsch, Helge; Stock, Norbert; Lee, Ji Sun; Chang, Jong-San; Llewellyn, Philip L
2013-02-11
A high-throughput gas adsorption apparatus is presented for the evaluation of adsorbents of interest in gas storage and separation applications. This instrument is capable of measuring complete adsorption isotherms up to 40 bar on six samples in parallel using as little as 60 mg of material. Multiple adsorption cycles can be carried out and four gases can be used sequentially, giving as many as 24 adsorption isotherms in 24 h. The apparatus has been used to investigate the effect of metal center (MIL-100) and functional groups (CAU-10) on the adsorption of N(2), CO(2), and light hydrocarbons on MOFs. This demonstrates how it can serve to evaluate sample quality and adsorption reversibility, to determine optimum activation conditions and to estimate separation properties. As such it is a useful tool for the screening of novel adsorbents for different applications in gas separation, providing significant time savings in identifying potentially interesting materials.
Flux pinning and inhomogeneity in magnetic nanoparticle doped MgB2/Fe wires
NASA Astrophysics Data System (ADS)
Novosel, Nikolina; Pajić, Damir; Mustapić, Mislav; Babić, Emil; Shcherbakov, Andrey; Horvat, Joseph; Skoko, Željko; Zadro, Krešo
2010-06-01
The effects of magnetic nanoparticle doping on superconductivity of MgB2/Fe wires have been investigated. Fe2B and SiO2-coated Fe2B particles with average diameters 80 and 150 nm, respectively, were used as dopands. MgB2 wires with different nanoparticle contents (0, 3, 7.5, 12 wt.%) were sintered at temperature 750°C. The magnetoresistivity and critical current density Jc of wires were measured in the temperature range 2-40 K in magnetic field B <= 16 T. Both transport and magnetic Jc were determined. Superconducting transition temperature Tc of doped wires decreases quite rapidly with doping level (~ 0.5 K per wt.%). This results in the reduction of the irreversibility fields Birr(T) and critical current densities Jc(B,T) in doped samples (both at low (5 K) and high temperatures (20 K)). Common scaling of Jc(B,T) curves for doped and undoped wires indicates that the main mechanism of flux pinning is the same in both types of samples. Rather curved Kramer's plots for Jc of doped wires imply considerable inhomogeneity.
Garcia, Ediberto; Newfang, Daniel; Coyle, Jayme P; Blake, Charles L; Spencer, John W; Burrelli, Leonard G; Johnson, Giffe T; Harbison, Raymond D
2018-07-01
Three independently conducted asbestos exposure evaluations were conducted using wire gauze pads similar to standard practice in the laboratory setting. All testing occurred in a controlled atmosphere inside an enclosed chamber simulating a laboratory setting. Separate teams consisting of a laboratory technician, or technician and assistant simulated common tasks involving wire gauze pads, including heating and direct wire gauze manipulation. Area and personal air samples were collected and evaluated for asbestos consistent with the National Institute of Occupational Safety Health method 7400 and 7402, and the Asbestos Hazard Emergency Response Act (AHERA) method. Bulk gauze pad samples were analyzed by Polarized Light Microscopy and Transmission Electron Microscopy to determine asbestos content. Among air samples, chrysotile asbestos was the only fiber found in the first and third experiments, and tremolite asbestos for the second experiment. None of the air samples contained asbestos in concentrations above the current permissible regulatory levels promulgated by OSHA. These findings indicate that the level of asbestos exposure when working with wire gauze pads in the laboratory setting is much lower than levels associated with asbestosis or asbestos-related lung cancer and mesothelioma. Copyright © 2018. Published by Elsevier Inc.
Non-Lethal Weapons for Today’s Operations
2011-01-01
Division Chief Lieutenant Colonel Paul L. Scholl : paul.scholl@usmc.mil Acquisition Division Chief Kevin J. Swenson: kevin.swenson@usmc.mil Technology...Division Chief David B. Law: david.b.law1@usmc.mil Health Effects Officer Mary R. Williams : mary.r.williams1.ctr@usmc.mil Annual Report Editorial Board...Douglas J. Jerothe Lieutenant Colonel Paul L. Scholl Susan D. LeVine Kevin J. Swenson Kelley S. Hughes Alicia J. Owsiak Publication Management Bethel
Recent Developments in Silver/Zinc Rechargeable Cell Studies
NASA Technical Reports Server (NTRS)
Lewis, Harlan L.
2001-01-01
This viewgraph presentation discusses silver/zinc cell casing configurations and test results examining discharge capacity and silver migration comparisons. The following recommendations were proposed: 1) Use silver-treated cellophane instead of clear cellophane; 2) Use split wrap for cellophane whenever possible; and 3) Strongly consider use of sausage casing with PVA film in the following configuration: 1-mil (tubular) SC/1-mil PVA film/2.3-mil plain or 6-mil fiber-reinforced SC tubular.
Hydrogen storage behaviors of Ni-doped graphene Oxide/MIL-101 hybrid composites.
Lee, Seul-Yi; Park, Soo-Jin
2013-01-01
In this work, Ni-doped graphene oxide/MIL-101 hybrid composites (Ni--GO/MIL) were prepared to investigate their hydrogen storage behaviors. Ni--GO/MIL was synthesized by adding Ni--GO in situ during the synthesis of MIL-101 using a hydrothermal process, which was conducted by conventional convection heating with Cr(III) ion as a metal center and telephthalic acid as organic ligands. The crystalline structures and morphologies were measured by X-ray diffraction (XRD) and scanning electron microscopy (SEM), respectively. The specific surface area and micropore volume were investigated by N2/77 K adsorption isotherms using the Brunauer-Emmett-Teller (BET) method and Dubinin-Radushkevic (D-R) equation, respectively. The hydrogen storage capacity was investigated by BEL-HP at 77 K and 1 bar. The obtained results show that Ni--GO/MIL presents new directions for achieving novel hybrid materials with higher hydrogen storage capacity.
Meaning in Life: A conceptual model for disaster nursing practice.
Noviana, Uki; Miyazaki, Misako; Ishimaru, Mina
2016-04-01
This study aimed to develop a conceptual model for understanding meaning in life (MIL) using respondents' quotations in the primary qualitative studies. The primary studies were selected from the PsycINFO, PsycARTICLES and CINAHL databases using keywords 'meaning in life', 'meaning of life', 'purpose in life' and 'will to meaning'. Respondents' quotations in the primary studies were analysed interpretatively to identify MIL from the respondents' perspectives. The data were synthesized to integrate findings from 10 selected primary studies. The findings identified (i) six sources of MIL (e.g. having a significant others, having new experiences and performing spiritual activities); (ii) eight components of MIL (e.g. focusing on self, connecting to others, contributing to others and having a sense of direction and purpose); and (iii) the emotional outcomes of having MIL: happiness, satisfaction and joy. Through a discussion of the findings, a conceptual model of MIL emerged. © 2016 John Wiley & Sons Australia, Ltd.
Otero, Cassi L.
2007-01-01
The U.S. Geological Survey, in cooperation with the San Antonio Water System, conducted a 4-year study during 2002?06 to identify major flow paths in the Edwards aquifer in northeastern Bexar and southern Comal Counties (study area). In the study area, faulting directs ground water into three hypothesized flow paths that move water, generally, from the southwest to the northeast. These flow paths are identified as the southern Comal flow path, the central Comal flow path, and the northern Comal flow path. Statistical correlations between water levels for six observation wells and between the water levels and discharges from Comal Springs and Hueco Springs yielded evidence for the hypothesized flow paths. Strong linear correlations were evident between the datasets from wells and springs within the same flow path and the datasets from wells in areas where flow between flow paths was suspected. Geochemical data (major ions, stable isotopes, sulfur hexafluoride, and tritium and helium) were used in graphical analyses to obtain evidence of the flow path from which wells or springs derive water. Major-ion geochemistry in samples from selected wells and springs showed relatively little variation. Samples from the southern Comal flow path were characterized by relatively high sulfate and chloride concentrations, possibly indicating that the water in the flow path was mixing with small amounts of saline water from the freshwater/saline-water transition zone. Samples from the central Comal flow path yielded the most varied major-ion geochemistry of the three hypothesized flow paths. Central Comal flow path samples were characterized, in general, by high calcium concentrations and low magnesium concentrations. Samples from the northern Comal flow path were characterized by relatively low sulfate and chloride concentrations and high magnesium concentrations. The high magnesium concentrations characteristic of northern Comal flow path samples from the recharge zone in Comal County might indicate that water from the Trinity aquifer is entering the Edwards aquifer in the subsurface. A graph of the relation between the stable isotopes deuterium and delta-18 oxygen showed that, except for samples collected following an unusually intense rain storm, there was not much variation in stable isotope values among the flow paths. In the study area deuterium ranged from -36.00 to -20.89 per mil and delta-18 oxygen ranged from -6.03 to -3.70 per mil. Excluding samples collected following the intense rain storm, the deuterium range in the study area was -33.00 to -20.89 per mil and the delta-18 oxygen range was -4.60 to -3.70 per mil. Two ground-water age-dating techniques, sulfur hexafluoride concentrations and tritium/helium-3 isotope ratios, were used to compute apparent ages (time since recharge occurred) of water samples collected in the study area. In general, the apparent ages computed by the two methods do not seem to indicate direction of flow. Apparent ages computed for water samples in northeastern Bexar and southern Comal Counties do not vary greatly except for some very young water in the recharge zone in central Comal County.
Du, Yucheng; Wang, Liping; Wang, Jinshu; Zheng, Guangwei; Wu, Junshu; Dai, Hongxing
2015-03-01
Flower-, wire-, and sheet-like MnO2-deposited diatomites have been prepared using a hydrothermal method with Mn(Ac)2, KMnO4 and/or MnSO4 as Mn source and diatomite as support. Physical properties of the materials were characterized by means of numerous analytical techniques, and their behaviors in the adsorption of chromium(VI) were evaluated. It is shown that the MnO2-deposited diatomite samples with different morphologies possessed high surface areas and abundant surface hydroxyl groups (especially the wire-like MnO2/diatomite sample). The wire-like MnO2/diatomite sample showed the best performance in the removal of Cr(VI), giving the maximum Cr(VI) adsorption capacity of 101 mg/g. Copyright © 2014. Published by Elsevier B.V.
Brindha, M.; Kumaran, N. Kurunji; Rajasigamani, K.
2014-01-01
Aim: The aim of this study is to evaluate, the influence of four types of sterilization/disinfection procedures (autoclave, hot air oven, glutaraldehyde, and ultraviolet [UV] light) on the tensile strength and surface topography of three orthodontic wires (stainless steel (SS), titanium - molybdenum alloy [TMA], and cobalt chromium (CoCr)). Materials and Methods: Sample comprised of three types of 8 inches straight length segments of orthodontic wires. They were divided into three groups according to wire composition comprising of 50 samples each. Totally 50 samples of each group were then equally divided into five subgroups according to sterilization method. After sterilization and disinfection of the experimental group, surface topography was examined with scanning electron microscope (SEM) and tensile strength was tested using universal testing machine. Result: The results of this study show that the mean ultimate tensile strength (UTS) of SS wire after four sterilization procedures were similar to the control group (1845.815 ± 142.29 MPa). The mean UTS of TMA wire increases after four sterilization procedures when compared with the control group (874.107 ± 275.939 MPa). The mean UTS of CoCr wire remains same after UV light disinfection, but increases after other three sterilization procedures when compared with the control group (1449.759 ± 156.586 MPa). SEM photographs of the present study shows gross increase in pitting roughness of the surface topography of all the three types of wires after four types of sterilization. Conclusion: Orthodontists who want to offer maximum safety for their patients can sterilize orthodontic wires before placement, as it does not deteriorate the tensile strength and surface roughness of the alloys. PMID:25210383
Brindha, M; Kumaran, N Kurunji; Rajasigamani, K
2014-07-01
The aim of this study is to evaluate, the influence of four types of sterilization/disinfection procedures (autoclave, hot air oven, glutaraldehyde, and ultraviolet [UV] light) on the tensile strength and surface topography of three orthodontic wires (stainless steel (SS), titanium - molybdenum alloy [TMA], and cobalt chromium (CoCr)). Sample comprised of three types of 8 inches straight length segments of orthodontic wires. They were divided into three groups according to wire composition comprising of 50 samples each. Totally 50 samples of each group were then equally divided into five subgroups according to sterilization method. After sterilization and disinfection of the experimental group, surface topography was examined with scanning electron microscope (SEM) and tensile strength was tested using universal testing machine. The results of this study show that the mean ultimate tensile strength (UTS) of SS wire after four sterilization procedures were similar to the control group (1845.815 ± 142.29 MPa). The mean UTS of TMA wire increases after four sterilization procedures when compared with the control group (874.107 ± 275.939 MPa). The mean UTS of CoCr wire remains same after UV light disinfection, but increases after other three sterilization procedures when compared with the control group (1449.759 ± 156.586 MPa). SEM photographs of the present study shows gross increase in pitting roughness of the surface topography of all the three types of wires after four types of sterilization. Orthodontists who want to offer maximum safety for their patients can sterilize orthodontic wires before placement, as it does not deteriorate the tensile strength and surface roughness of the alloys.
Ultrasonic Guided Waves for Aging Wire Insulation Assessment
NASA Technical Reports Server (NTRS)
Anastasi, Robert F.; Madaras, Eric I.
2001-01-01
Environmentally aged wire insulation can become brittle and crack and thus expose the underlying conductive wire to the potential for short circuits and fire. The feasibility of using ultrasonic guided waves to measure insulation condition was examined. First a simple model to study guided wave propagation in a bare and thin plastic coated wire was examined and then some aviation grade wire samples that had been heat-damaged. Initial measurements indicate that ultrasonic guided wave velocity can be used to monitor insulation stiffness.
2007-06-01
fasteners. Enviromental Spec Storage Temperature: -26 to 160 °F, Operating Temperature: -22 to 160 °F, Operating Humidity Range: 5% to 100% Non...Accessories Double 90° tongue and groove case design, with anti-tamper fasteners. Enviromental Spec Storage Temperature: -26 to 160 °F, Operating
Nonbibliographic Machine-Readable Data Bases in ARL Libraries. SPEC Kit 105.
ERIC Educational Resources Information Center
Westerman, Mel
This document is one of ten kits distributed annually by the Systems and Procedures Exchange Center (SPEC), a clearinghouse operated by the Association of Research Libraries, Office of Management Studies (ARL/OMS) that provides a central source of timely information and materials on the management and operations of large academic and research…
"FluSpec": A Simulated Experiment in Fluorescence Spectroscopy
ERIC Educational Resources Information Center
Bigger, Stephen W.; Bigger, Andrew S.; Ghiggino, Kenneth P.
2014-01-01
The "FluSpec" educational software package is a fully contained tutorial on the technique of fluorescence spectroscopy as well as a simulator on which experiments can be performed. The procedure for each of the experiments is also contained within the package along with example analyses of results that are obtained using the software.
Evolution & Status of Approval Plans. SPEC Kit 221.
ERIC Educational Resources Information Center
Flood, Susan, Comp.
This report documents the results of a survey on the current use and management of approval plans, and compares them with similar studies published in SPEC kits in 1982 and 1988. Overall, Association of Research Libraries (ARL) institutions still consider approval plans to be efficient and cost effective. Survey results include: (1) the percentage…
1994-02-03
STS-60 pilot Ken Reightler (front left) and Mission Commander Charlie Bolden (front right) lead the way from the O&C bldg. enroute to Discovery at Pad 39A. Behidn are (from felt) Mission Specs Sega adn Krikalev: Payload Commander Chang-Diaz: and Misssion Spec Davis. (Op. No. D6022)(Item D-112C)
Interlibrary Loan Trends: Staffing and Organization. SPEC Kit #187.
ERIC Educational Resources Information Center
Dearie, Tammie Nickelson, Comp.; Steel, Virginia, Comp.
Topics related to research library interlibrary loan staffing and organizational structures were explored through a survey conducted by the Systems and Procedures Exchange Center (SPEC) of the Association of Research Libraries. Data gathered from 82 libraries show a very small increase in the number of full-time equivalents in loan units between…
Library Systems Office Organization. SPEC Kit and SPEC Flyer 211.
ERIC Educational Resources Information Center
Muir, Scott P., Comp.
The roles and responsibilities of the library systems officer continues to change as libraries move beyond the automation of library functions to offering resources in electronic formats and electronic access to information about collections beyond the walls of the home institution. This survey was designed to collect data and document some of the…
Collection Development Organization and Committees. SPEC Kit 11.
ERIC Educational Resources Information Center
Association of Research Libraries, Washington, DC. Office of Management Studies.
This kit focuses on information that is useful for starting a collection development program. It contains 7 position descriptions, 10 documents on the role of committees, 4 organization charts, 5 documents on the organization of functions, and an analysis of a Systems and Procedures Exchange Center (SPEC) collection development survey. The survey,…
Analysis of Cervical Supernatant Samples Luminescence Using 355 nm Laser
NASA Astrophysics Data System (ADS)
Vaitkuviene, A.; Gegzna, V.; Kurtinaitiene, R.; Stanikunas, R.; Rimiene, J.; Vaitkus, J.
2010-05-01
The biomarker discovery for accurate detection and diagnosis of cervical carcinoma and its malignant precursors represents one of the current challenges in clinical medicine. Laser induced autofluorescence spectra in cervical smear content were fitted to predict the cervical epithelium diagnosis as a lab off "optical biopsy" method. Liquid PAP supernatant sediment dried on Quartz plate spectroscopy was performed by 355 nm Nd YAG microlaser STA-1 (Standa, Ltd). For comparison a liquid supernatant spectroscopy was formed by laboratory "Perkin Elmer LS 50B spetrometer at 290, 300, 310 nm excitations. Analysis of spectrum was performed by approximation using the multi-peaks program with Lorentz functions for the liquid samples and with Gaussian functions for the dry samples. Ratio of spectral components area to the area under whole experimental curve (SPP) was calculated. The spectral components were compared by averages of SPP using Mann-Whitney U-test in histology groups. Results. Differentiation of Normal and HSIL/CIN2+ cases in whole supernatant could be performed by stationary laboratory lamp spectroscopy at excitation 290 nm and emission >379 nm with accuracy AUC 0,69, Sens 0,72, Spec 0,65. Differentiation Normal versus HSIL/CIN2+ groups in dried enriched supernatant could be performed by 355 nm microlaser excitation at emission 405-424 nm with accuracy (AUC 0,96, Sens 0,91, Spec 1.00). Diagnostic algorithm could be created for all histology groups differentiation under 355 nm excitation. Microlaser induced "optical biopsy "looks promising method for cervical screening at the point of care.
DFT algorithms for bit-serial GaAs array processor architectures
NASA Technical Reports Server (NTRS)
Mcmillan, Gary B.
1988-01-01
Systems and Processes Engineering Corporation (SPEC) has developed an innovative array processor architecture for computing Fourier transforms and other commonly used signal processing algorithms. This architecture is designed to extract the highest possible array performance from state-of-the-art GaAs technology. SPEC's architectural design includes a high performance RISC processor implemented in GaAs, along with a Floating Point Coprocessor and a unique Array Communications Coprocessor, also implemented in GaAs technology. Together, these data processors represent the latest in technology, both from an architectural and implementation viewpoint. SPEC has examined numerous algorithms and parallel processing architectures to determine the optimum array processor architecture. SPEC has developed an array processor architecture with integral communications ability to provide maximum node connectivity. The Array Communications Coprocessor embeds communications operations directly in the core of the processor architecture. A Floating Point Coprocessor architecture has been defined that utilizes Bit-Serial arithmetic units, operating at very high frequency, to perform floating point operations. These Bit-Serial devices reduce the device integration level and complexity to a level compatible with state-of-the-art GaAs device technology.
Garcia, Luís Filipe; de Oliveira, Luís Caldas; de Matos, David Martins
2016-01-01
This study compared the performance of two statistical location-aware pictogram prediction mechanisms, with an all-purpose (All) pictogram prediction mechanism, having no location knowledge. The All approach had a unique language model under all locations. One of the location-aware alternatives, the location-specific (Spec) approach, made use of specific language models for pictogram prediction in each location of interest. The other location-aware approach resulted from combining the Spec and the All approaches, and was designated the mixed approach (Mix). In this approach, the language models acquired knowledge from all locations, but a higher relevance was assigned to the vocabulary from the associated location. Results from simulations showed that the Mix and Spec approaches could only outperform the baseline in a statistically significant way if pictogram users reuse more than 50% and 75% of their sentences, respectively. Under low sentence reuse conditions there were no statistically significant differences between the location-aware approaches and the All approach. Under these conditions, the Mix approach performed better than the Spec approach in a statistically significant way.
Defense Standardization Program Status of Standardization Projects
1993-09-30
GS N 7320 0903 A-A-XXX VEGETABLE PEELING MACHINE ELEC GL B4 A 931 934 934 A GL YDI 99 GS N 7320 0904 MIL-D-13053D NOT 1 DOUGH TROUGHS GL H5 932 941...934 G GL YDi 99 GS U 7320 0906 MIL-D-2471D DOUGH DIVIDING MACHINE GL H5 931 941 934 G GL YDV 99 GS U 7320 0907 MIL-B-43386B NOT 1 BIN INGRE MOBILE GL...H5 932 941 934 G GL YDI 99 GS U 7320 0908 MIL-D-2351C DOUGH INTERMED PRF MACHINE GL H5 932 941 934 G GL YDV 99 GS U 7320 0909 MIL-D-2352C DOUGH
NASA Technical Reports Server (NTRS)
Righter, Kevin; Keller, L. P.; Rahman, Z.; Christoffersen, R.
2012-01-01
MIL 03346 is one of the most mesostasis-rich nakhlites [1] and thought to have equilibrated at oxygen fugacities near the fayalite-magnetite-quartz oxygen (FMQ) buffer ([2,3]). Studies of FeTi oxides in nakhlites have led to additional constraints on their equilibration temperatures and fO2s [4,5,6,7]. Comparison of these results to fO2s calculated for shergottites indicates that nakhlites are among the most oxidized samples from the martian meteorite suite [2]. The mesostasis of MIL 03346 contains skeletal titanomagnetite. Several scientists noticed several years ago (e.g. [8]) that this titanomagnetite contains very fine oxidation-driven exsolution lamellae (Figure 1). However, the lamellae are so small that they cannot be characterized by electron microprobe analysis (EMPA). Here we select several areas for focused ion beam (FIB) extraction, prepare transmission electron microscopy (TEM) foils, and identify and analyze the lamellae using TEM at the Johnson Space Center (JSC). The resulting analyses are combined with previous work on nakhlites to interpret the thermal and oxidation history of this meteorite group.
Infrared Radiometric Scanning System for Flexible Package Seal Defects
1973-12-01
spotted. Pccfcarres tasted Two types of packages currently used for therm- ally processed foods were tested. Both had an outer layer of 0.5-mil...polyester and a middle layer of 0.35- mil aluminum foil. The inner, heat-seal layer was either 3-mil high-dtnsity polyethylene or 3-mil mod- ified...a variety ol causes—including urease . moisture, occluded food fibres or particles, threads, voids and wrinkles. Defects as small as 0.5 mg. of free
Laughman, Brian; Wang, Ling; Lund, Thomas S.; Collins, Richard L.
2018-01-01
Abstract An anelastic numerical model is employed to explore the dynamics of gravity waves (GWs) encountering a mesosphere inversion layer (MIL) having a moderate static stability enhancement and a layer of weaker static stability above. Instabilities occur within the MIL when the GW amplitude approaches that required for GW breaking due to compression of the vertical wavelength accompanying the increasing static stability. Thus, MILs can cause large‐amplitude GWs to yield instabilities and turbulence below the altitude where they would otherwise arise. Smaller‐amplitude GWs encountering a MIL do not lead to instability and turbulence but do exhibit partial reflection and transmission, and the transmission is a smaller fraction of the incident GW when instabilities and turbulence arise within the MIL. Additionally, greater GW transmission occurs for weaker MILs and for GWs having larger vertical wavelengths relative to the MIL depth and for lower GW intrinsic frequencies. These results imply similar dynamics for inversions due to other sources, including the tropopause inversion layer, the high stability capping the polar summer mesopause, and lower frequency GWs or tides having sufficient amplitudes to yield significant variations in stability at large and small vertical scales. MILs also imply much stronger reflections and less coherent GW propagation in environments having significant fine structure in the stability and velocity fields than in environments that are smoothly varying. PMID:29576994
NASA Astrophysics Data System (ADS)
Fritts, David C.; Laughman, Brian; Wang, Ling; Lund, Thomas S.; Collins, Richard L.
2018-01-01
An anelastic numerical model is employed to explore the dynamics of gravity waves (GWs) encountering a mesosphere inversion layer (MIL) having a moderate static stability enhancement and a layer of weaker static stability above. Instabilities occur within the MIL when the GW amplitude approaches that required for GW breaking due to compression of the vertical wavelength accompanying the increasing static stability. Thus, MILs can cause large-amplitude GWs to yield instabilities and turbulence below the altitude where they would otherwise arise. Smaller-amplitude GWs encountering a MIL do not lead to instability and turbulence but do exhibit partial reflection and transmission, and the transmission is a smaller fraction of the incident GW when instabilities and turbulence arise within the MIL. Additionally, greater GW transmission occurs for weaker MILs and for GWs having larger vertical wavelengths relative to the MIL depth and for lower GW intrinsic frequencies. These results imply similar dynamics for inversions due to other sources, including the tropopause inversion layer, the high stability capping the polar summer mesopause, and lower frequency GWs or tides having sufficient amplitudes to yield significant variations in stability at large and small vertical scales. MILs also imply much stronger reflections and less coherent GW propagation in environments having significant fine structure in the stability and velocity fields than in environments that are smoothly varying.
Therapeutic effect of irradiation of magnetic infrared laser on osteoarthritis rat model.
Moon, Chul-Hwan; Kwon, Ogon; Woo, Chang-Hoon; Ahn, Hee-Duk; Kwon, Young-Sam; Park, Soo-Jin; Song, Chang-Hyun; Ku, Sae-Kwang
2014-01-01
Osteoarthritis (OA) is a degenerative joint disease caused by articular cartilage loss. Many complementary and alternative medicines for OA have been reported so far, but the effectiveness is controversial. Previously, we have shown anti-inflammatory effects of low level laser therapy with static magnetic field, magnetic infrared laser (MIL), in various animal models. Therefore, the beneficial effects were examined in OA rat model. Rats were divided by six groups; no treatment controls of sham and OA model, three MIL treatment groups of OA model at 6.65, 2.66 and 1.33 J cm(-2), and Diclofenac group of OA model with 2 mg kg(-1) diclofenac sodium. The OA control exhibited typical symptoms of OA, but 4-week MIL treatment improved the functional movement of knee joint with reduced edematous changes. In addition, cartilage GAGs were detected more in all MIL treatment groups than OA control. It suggests that 4-week MIL irradiation has dose-dependent anti-inflammatory and chondroprotective effects on OA. Histopathological analyses revealed that MIL treatment inhibits the cartilage degradation and enhances chondrocyte proliferation. The fact that MIL has an additional potential for the cartilage formation and no adverse effects can be regarded as great advantages for OA treatment. These suggest that MIL can be useful for OA treatment. © 2014 The American Society of Photobiology.
Increased Thermal Conductivity in Metal-Organic Heat Carrier Nanofluids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nandasiri, Manjula I.; Liu, Jian; McGrail, B. Peter
2016-06-15
Metal organic heat carriers (MOHCs) are recently developed nanofluids containing metal organic framework (MOF) nanoparticles dispersed in various base fluids including refrigerants (R245Fa) and methanol. MOHCs utilize the MOF properties to improve the thermo-physical properties of base fluids. Here, we report the synthesis and characterization of MOHCs containing nanoMIL-101(Cr) and graphene oxide (GO) in an effort to improve the thermo-physical properties of various base fluids. MOHC containing MIL-101(Cr)/GO nanocomposites showed enhanced surface area, porosity, and nitrogen adsorption compared with the intrinsic nano MIL-101(Cr) and the properties depend on the amount of GO added. Powder X-ray diffraction (PXRD) confirmed the preservedmore » crystallinity of MIL-101(Cr) in all nanocomposites with the absence of any unreacted GO. Scanning electron microscopy images confirmed the presence of near spherical MIL-101(Cr) nanoparticles in the range of 40-80 nm in diameter. MOHC nanofluids containing MIL-101(Cr)/GO in methanol exhibited significant enhancement in the thermal conductivity (by approxi-mately 50%) relative to that of the intrinsic nano MIL-101(Cr) in methanol. The thermal conductivity of base fluid (methanol) was enhanced by about 20 %. The enhancement in the thermal conductivity of nanoMIL-101(Cr) MOHCs due to graphene oxide functionalization is explained using a classical Maxwell model.« less
Speech-driven environmental control systems--a qualitative analysis of users' perceptions.
Judge, Simon; Robertson, Zoë; Hawley, Mark; Enderby, Pam
2009-05-01
To explore users' experiences and perceptions of speech-driven environmental control systems (SPECS) as part of a larger project aiming to develop a new SPECS. The motivation for this part of the project was to add to the evidence base for the use of SPECS and to determine the key design specifications for a new speech-driven system from a user's perspective. Semi-structured interviews were conducted with 12 users of SPECS from around the United Kingdom. These interviews were transcribed and analysed using a qualitative method based on framework analysis. Reliability is the main influence on the use of SPECS. All the participants gave examples of occasions when their speech-driven system was unreliable; in some instances, this unreliability was reported as not being a problem (e.g., for changing television channels); however, it was perceived as a problem for more safety critical functions (e.g., opening a door). Reliability was cited by participants as the reason for using a switch-operated system as back up. Benefits of speech-driven systems focused on speech operation enabling access when other methods were not possible; quicker operation and better aesthetic considerations. Overall, there was a perception of increased independence from the use of speech-driven environmental control. In general, speech was considered a useful method of operating environmental controls by the participants interviewed; however, their perceptions regarding reliability often influenced their decision to have backup or alternative systems for certain functions.
Ion Release and Galvanic Corrosion of Different Orthodontic Brackets and Wires in Artificial Saliva.
Tahmasbi, Soodeh; Sheikh, Tahereh; Hemmati, Yasamin B
2017-03-01
To investigate the galvanic corrosion of brackets manufactured by four different companies coupled with stainless steel (SS) or nickel-titanium (NiTi) wires in an artificial saliva solution. A total of 24 mandibular central incisor Roth brackets of four different manufacturers (American Orthodontics, Dentaurum, Shinye, ORJ) were used in this experimental study. These brackets were immersed in artificial saliva along with SS or NiTi orthodontic wires (0.016'', round) for 28 days. The electric potential difference of each bracket/ wire coupled with a saturated calomel reference electrode was measured via a voltmeter and recorded constantly. Corrosion rate (CR) was calculated, and release of ions was measured with an atomic absorption spectrometer. Stereomicroscope was used to evaluate all samples. Then, samples with corrosion were further assessed by scanning electron microscope and energy-dispersive X-ray spectroscopy. Two-way analysis of variance was used to analyze data. Among ions evaluated, release of nickel ions from Shinye brackets was significantly higher than that of other brackets. The mean potential difference was significantly lower in specimens containing a couple of Shinye brackets and SS wire compared with other specimens. No significant difference was observed in the mean CR of various groups (p > 0.05). Microscopic evaluation showed corrosion in two samples only: Shinye bracket coupled with SS wire and American Orthodontics bracket coupled with NiTi wire. Shinye brackets coupled with SS wire showed more susceptibility to galvanic corrosion. There were no significant differences among specimens in terms of the CR or released ions except the release of Ni ions, which was higher in Shinye brackets.
NASA Astrophysics Data System (ADS)
Deutsch, Assaf; Pevzner, Eliyahu; Jaronkin, Alex; Mayevsky, Avraham
2004-06-01
Monitoring of tissue vitality (oxygen supply/demand) in real time is very rare in clinical practice although its use as an early warning alarming system, for clinical care medicine, is very practical. In our previous communication (SPIE 2003) we described the Tissue Spectroscope - TiSpec02, by which tissue microcirculatory blood flow (TBF) and mitochondrial NADH fluorescence were measured using a single light source (390nm). In order to improve the measurement capabilities as well as to decrease dramatically the size and cost of this clinical device, we have changed the TiSpec02 into a multi-wavelength illumination system in the new TiSpec03. In order to measure microcirculatory blood flow by laser Doppler flowmetry we used a 785nm laser diode. For mitochondrial NADH fluorescence measurement we adopted the 370nm LED. For the determination of the oxygenation level of hemoglobin (HbO2) we used the 2-wavelength reflectance technique. This new monitored parameter that was added to the TiSpec03 increases the accuracy of the diagnosis of tissue vitality. The bundle of optical fibers used to connect the tissue to the TiSpec03, was integrated into a special anchoring methodology depending on the monitored tissue or organ. In order to test the performance of the improved TiSpec we have used it in experimental animals brain models exposed to various pathophysiological conditions. Rats and gerbils were anesthetized and the fiber optic probe was located epidurally used dental acrylic cement. During anoxia and ischemia the lack of O2 led to a clear decrease in TBF and HbO2 while NADH shows a large elevation. When brain activation was induced by cortical spreading depression (SD), the elevated O2 consumption was recorded as a large oxidation (decrease) of mitochondrial NADH while TBF increase dramatically. Blood HbO2 was not affected significantly by the SD wave.
Pan, Xuming; Zhu, Mingzhuang; Ma, Honggang; Al-Rasheid, Khaled A S; Hu, Xiaozhong
2013-09-01
The morphology and infraciliature of two novel marine scuticociliates, Metanophrys orientalis spec. nov. and Uronemella sinensis spec. nov., collected from sandy beaches at Qingdao, China, were investigated using live observation and protargol-staining methods. Metanophrys orientalis spec. nov. is distinguished by the following characteristics: marine habitat and a slender to elongate oval body with pointed anterior end and rounded caudal end, in vivo about 25-50 µm long; buccal field about a quarter to a third of body length; nine or ten somatic kineties with dikinetids approximately in anterior half of body, monokinetids in posterior half; membranelles 1 and 2 almost equal in length and composed of two and three longitudinal rows of kinetids respectively; paroral membrane with zigzag structure extending anteriorly to middle portion of membranelle 2; contractile vacuole pore located at posterior end of somatic kinety 1. The genus Uronemella is redefined as follows: marine form with an elongate-elliptical or inverted pear-shaped body; apical plate conspicuous; buccal field about two-thirds of body length, cytostome subequatorially located; oral apparatus Uronema-like; somatic kineties comprising a mixture of dikinetids and monokinetids. Uronemella sinensis spec. nov. is recognized by having an elongate-elliptical body with truncated apical frontal plate, size in vivo about 25-35 × 15-20 µm, nine or ten somatic kineties, membranelle 1 consisting of two or three basal bodies, contractile vacuole pore at posterior end of somatic kinety 1. This study also compared the small-subunit rRNA gene sequences of these two species with other closely related species to show the sequence divergence, which ranged from 3.53 to 9.60%. Phylogenetic analyses support the contention that the genus Uronemella is monophyletic, while Metanophrys is non-monophyletic.
Direct impact aerosol sampling by electrostatic precipitation
Braden, Jason D.; Harter, Andrew G.; Stinson, Brad J.; Sullivan, Nicholas M.
2016-02-02
The present disclosure provides apparatuses for collecting aerosol samples by ionizing an air sample at different degrees. An air flow is generated through a cavity in which at least one corona wire is disposed and electrically charged to form a corona therearound. At least one grounded sample collection plate is provided downstream of the at least one corona wire so that aerosol ions generated within the corona are deposited on the at least one grounded sample collection plate. A plurality of aerosol samples ionized to different degrees can be generated. The at least one corona wire may be perpendicular to the direction of the flow, or may be parallel to the direction of the flow. The apparatus can include a serial connection of a plurality of stages such that each stage is capable of generating at least one aerosol sample, and the air flow passes through the plurality of stages serially.
Tőkés, Tímea; Szentmártoni, Gyöngyvér; Torgyík, László; Kajáry, Kornélia; Lengyel, Zsolt; Györke, Tamás; Molnár, Béla Á; Tőkés, Anna-Mária; Kulka, Janina; Dank, Magdolna
2015-04-01
To evaluate (I) trastuzumab-containing primary systemic therapy (PST) in human epidermal growth factor receptor 2 (Her2) overexpressing breast carcinomas.; (II) compare the patients who achieved and those who did not achieve pathological complete remission (pCR), and (III) analyze the accuracy of different clinical-imaging modalities in tumor response monitoring. 188 patients who received PST between 2008 and 2014 were reviewed and 43 Her2 overexpressing breast cancer patients (28 Luminal B/Her2-positive and 15 Her2-positive) were enrolled. 26 patients received mostly taxane-based PST without trastuzumab (Group 1) and 17 patients received trastuzumab-containing PST (Group 2). We compared the concordance between pCR and complete remission (CR) defined by breast-ultrasound, CR defined by standard 18F-fluoro-deoxy-glucose positron emission tomography and computerized tomography (FDG-PET/CT) criteria (Method 1) and CR defined by a novel, breast cancer specific FDG-PET/CT criteria (Method 2). Sensitivity (sens), specificity (spec), and positive (PPV) and negative predictive values (NPV) were calculated. Ten patients (38.5%) in Group 1 and eight (47%) in Group 2 achieved pCR. pCR was significantly more frequent in Her2-positive than in Luminal B/Her2-positive tumors in both Group 1: (P=0.043) and Group 2: (P=0.029). PET/CT evaluated by the breast cancer specific criteria (Method 2) differentiated pCR from non-pCR more accurately in both groups (Group 1: sens=77.8%, spec=%, PPV=100%, NPV=71.4%; Group 2: sens=87.5%, spec=62.5%, PPV=70%, NPV=83.3%) than standard PET/CT criteria (Method 1) (Group 1: sens=22.2% spec=100% PPV=100% NPV=41.7%; in Group 2: sens=37.5%, spec=87.5%, PPV=75% NPV=58.3%) or breast ultrasound (Group 1, sens=83.3% spec=25% PPV=62.5% NPV=50%; Group 2, sens=100% spec=12.5% PPV=41.6% NPV=100%). The benefit of targeted treatment with trastuzumab-containing PST in Her2 overexpressing breast cancer was defined in terms of pCR rate. Luminal B/Her2-positive subtype needs further subdivision to identify patients who would benefit from PST. Combined evaluation of tumor response by our novel, breast cancer specific FDG-PET/CT criteria accurately differentiated pCR from non-pCR patients.
Alternative methods of refraction: a comparison of three techniques.
Smith, Kyla; Weissberg, Erik; Travison, Thomas G
2010-03-01
In the developing world, refractive error is a common untreated cause of visual impairment. Lay people may use portable tools to overcome this issue. This study compares three methods of measuring spherical refractive error (SE) performed by a lay technician to a subjective refraction (SR) in a controlled clinical setting and a field trial. Fifty subjects from Boston, MA (mean age, 24.3 y ± 1.5) and 50 from Nicaragua (mean age, 40 y ± 13.7) were recruited. Measures (performed on right eye only) included (1) AdSpecs, adjustable spectacles; (2) Focometer, focusable telescope; (3) Predetermined Lens Refraction (PLR), prescripted lens choices; (4) SR. Examiners were masked and techniques randomized. Student t-test compared mean SE determined by each method (95% confidence intervals). AdSpecs repeatability was evaluated by repeating measures of SE and visual acuity (VA). Mean (SD) SE for Boston subjects determined by SR was -2.46 D (3.2). Mean (SD) SE for AdSpecs, Focometer -2.41 D (2.69), -2.80 D (2.82). Among the 30 Boston subjects considered in analyses of PLR data (see Methods), PLR and SR obtained mean (SD) values of -0.65 D (1.36) and -0.41 D (1.67), respectively, a statistically significant difference of -0.24 D (p = 0.046, t = 2.09). Mean PLR SE had greatest deviation from SR, 0.67 D. 20/20 VA was achieved by SR, AdSpecs, Focometer, and PLR in 98, 88, 84, 96% of subjects. Mean (SD) SE for Nicaragua subjects determined by SR was +0.51 D (0.71). Mean (SD) SE for AdSpecs, Focometer, and PLR was +0.68 D (0.83), +0.42 D (1.13), +0.27 D (0.79). Mean PLR SE had the greatest deviation from the SR by 0.24 D, which was a statistically significant difference. 20/20 VA was achieved by SR, AdSpecs, Focometer, and PLR in 78, 66, 66, 88% of subjects. Repeated measures by AdSpecs were highly correlated. Although the mean value obtained by each technique may be similar to that obtained by SR, substantial and clinically meaningful differences may exist in some individuals; however, where SR is unavailable they could be a feasible alternative.
Verhaegh, Pauline; Bavalia, Roisin; Winkens, Bjorn; Masclee, Ad; Jonkers, Daisy; Koek, Ger
2018-06-01
Nonalcoholic fatty liver disease is a rapidly increasing health problem. Liver biopsy analysis is the most sensitive test to differentiate between nonalcoholic steatohepatitis (NASH) and simple steatosis (SS), but noninvasive methods are needed. We performed a systematic review and meta-analysis of noninvasive tests for differentiating NASH from SS, focusing on blood markers. We performed a systematic search of the PubMed, Medline and Embase (1990-2016) databases using defined keywords, limited to full-text papers in English and human adults, and identified 2608 articles. Two independent reviewers screened the articles and identified 122 eligible articles that used liver biopsy as reference standard. If at least 2 studies were available, pooled sensitivity (sens p ) and specificity (spec p ) values were determined using the Meta-Analysis Package for R (metafor). In the 122 studies analyzed, 219 different blood markers (107 single markers and 112 scoring systems) were identified to differentiate NASH from simple steatosis, and 22 other diagnostic tests were studied. Markers identified related to several pathophysiological mechanisms. The markers analyzed in the largest proportions of studies were alanine aminotransferase (sens p , 63.5% and spec p , 74.4%) within routine biochemical tests, adiponectin (sensp, 72.0% and spec p , 75.7%) within inflammatory markers, CK18-M30 (sens p , 68.4% and spec p , 74.2%) within markers of cell death or proliferation and homeostatic model assessment of insulin resistance (sens p , 69.0% and spec p , 72.7%) within the metabolic markers. Two scoring systems could also be pooled: the NASH test (differentiated NASH from borderline NASH plus simple steatosis with 22.9% sens p and 95.3% spec p ) and the GlycoNASH test (67.1% sens p and 63.8% spec p ). In the meta-analysis, we found no test to differentiate NASH from SS with a high level of pooled sensitivity and specificity (≥80%). However, some blood markers, when included in scoring systems in single studies, identified patients with NASH with ≥80% sensitivity and specificity. Replication studies and more standardized study designs are urgently needed. At present, no marker or scoring system can be recommended for use in clinical practice to differentiate NASH from simple steatosis. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Earle, Lieko
We have built Z-Spec, a broadband spectrometer for millimeter-wave astrophysics. The instrument's instantaneous bandwidth of 185-305 GHz covers the entire 1 millimeter atmospheric transmission window with a moderate resolving power ( R = n/Dn) of 250-350. The spectrometer employs a novel architecture called WaFIRS (Waveguide Far-Infrared Spectrometer) which confines the light propagation for a curved diffraction grating within a parallel-plate waveguide, resulting in a minimum mechanical envelope. An array of 160 silicon- nitride micromesh bolometers is cooled to 60 mK via an adiabatic demagnetization refrigerator (ADR) backed by a closed-cycle 3 He- 4 He sorption pump refrigerator. Z-Spec's compact design serves as a concept demonstration for a future far-infrared spectrometer aboard a cold telescope in space. Routine observations with Z-Spec from the Caltech Submillimeter Observatory on Mauna Kea have been conducted since April 2006, and the instrument currently achieves good sensitivities that are within a factor of two of the photon background limit set by the atmosphere and telescope. Z-Spec's primary science objectives are to determine the redshifts of faint submillimeter galaxies using the 12 CO rotational ladder, and to conduct systematic line surveys of local galaxies. The millimeter waveband hosts low- to mid- J rotational transitions for several molecular species which trace the dense interstellar gas associated with active star formation. Z-Spec's bandwidth offers a unique advantage over the traditional single-dish heterodyne approach: the spectral lines and the corresponding continua are all observed simultaneously, greatly reducing relative uncertainties in flux calibration and line-to-continuum ratios. The starburst galaxy NGC 253 was observed with Z-Spec in November 2006, for a total integration of 3.49 hours over two nights. NGC 253 is one of the brightest neighbors outside the Local Group of galaxies and its compact nuclear region is a site of prodigious star-formation. Twenty-one transitions in 13 species were detected at greater than 3s, including the well-known density tracers HCO + , HCN, HNC, and three transitions of CS. The results are compared with large-velocity-gradient (LVG) radiative-transfer simulations and the implications for the physical conditions of the gas in the starburst core are discussed.
Fernandes, Diana M; Barbosa, André D S; Pires, João; Balula, Salete S; Cunha-Silva, Luís; Freire, Cristina
2013-12-26
A novel hybrid composite material, PMo10V2@MIL-101 was prepared by the encapsulation of the tetra-butylammonium (TBA) salt of the vanadium-substituted phosphomolybdate [PMo10V2O40](5-) (PMo10V2) into the porous metal-organic framework (MOF) MIL-101(Cr). The materials characterization by powder X-ray diffraction, Fourier transform infrared spectra and scanning electron microscopy confirmed the preparation of the composite material without disruption of the MOF porous structure. Pyrolytic graphite electrodes modified with the original components (MIL-101(Cr), PMo10V2), and the composite material PMo10V2@MIL-101 were prepared and their electrochemical responses were studied by cyclic voltammetry. Surface confined redox processes were observed for all the immobilized materials. MIL-101(Cr) showed one-electron reduction process due to chromium centers (Cr(III) → Cr(II)), while PMo10V2 presented five reduction processes: the peak at more positive potentials is attributed to two superimposed 1-electron vanadium reduction processes (V(V) → V(IV)) and the other four peaks to Mo-centred two-electron reduction processes (Mo(VI) → Mo(V)). The electrochemical behavior of the composite material PMo10V2@MIL-101 showed both MIL-101(Cr) and PMo10V2 redox features, although with the splitting of the two vanadium processes and the shift of the Mo- and Cr- centered processes to more negative potentials. Finally, PMo10V2@MIL-101 modified electrode showed outstanding enhanced vanadium-based electrocatalytic properties towards ascorbic acid oxidation, in comparison with the free PMo10V2, as a result of its immobilization into the porous structure of the MOF. Furthermore, PMo10V2@MIL-101 modified electrode showed successful simultaneous detection of ascorbic acid and dopamine.
Uma, Kasimayan; Pan, Guan-Ting; Yang, Thomas C.-K.
2017-01-01
Metal organic framework (MOF) of MIL-101(Cr)-Silica (SiO2) composites with highly mesoporous and uniform dispersions were synthesized by a microwave-assisted hydrothermal method followed by the sol-gel technique. Water vapor adsorption experiments were conducted on the MIL-101(Cr)-SiO2 composites for industrial adsorption chiller applications. The effects of MIL-101(Cr)-SiO2 mixing ratios (ranging from 0% to 52%), the surface area and amount of Lewis and Brønsted sites were comprehensively determined through water vapor adsorption experiments and the adsorption mechanism is also explained. The BET and Langmuir results indicate that the adsorption isotherms associated with the various MIL-101(Cr)-SiO2 ratios demonstrated Type I and IV adsorption behavior, due to the mesoporous structure of the MIL-101(Cr)-SiO2. It was observed that the increase in the amount of Lewis and Brønsted sites on the MIL-101(Cr)-SiO2 composites significantly improves the water vapor adsorption efficiency, for greater stability during the water vapor adsorption experiments. PMID:28772969
NASA Astrophysics Data System (ADS)
Stalker, J. C.; Price, R. M.; Swart, P. K.
2005-05-01
Biscayne Bay is a sub-tropical estuary located on the carbonate platform of south Florida. The water occupying Biscayne Bay is a balance of saltwater influx from the open ocean and freshwater inputs from precipitation, surface water runoff, and submarine groundwater discharge. The bays watershed includes a total of 3 million inhabitants, the major urban centers of Miami and Ft. Lauderdale, as well as the Everglades system. With the development of south Florida, the natural diffuse groundwater and stream flow into the bay has been replaced by a large system of canals and levees in an effort to control flooding and drain swampland. The Comprehensive Everglades Restoration Plan includes changes in the freshwater deliveries to Biscayne Bay from point-source discharges via canals to non-point source discharges via wetlands and groundwater flow. The balance of salinity in Biscayne Bay effects sensitive seagrass and tidal ecosystems including numerous species of corals and other biota. A comprehensive understanding of the flow of freshwater into the bay is crucial to future planned developments and restorations. The goal of this study is to use naturally occurring geochemical constituents as tracers to identify and quantify the sources of freshwater, i.e. rainfall, canal flow, and groundwater, discharge to Biscayne Bay. In this study, discrete samples of precipitation, canal water, terrestrial groundwater, marine groundwater, and bay surface water are collected monthly and analyzed for the stable isotopes of hydrogen and oxygen as well as for major cations and anions. Initial results indicate that fresh groundwater has an isotopic signature (del 18O = -2.66 per mil, del D, -7.60 per mil) similar to rainfall (del 18O = -2.86 per mil, del D =-4.78 per mil). In contrast canal water has a heavy isotopic signature (del 18O = -0.46 per mil, del D = -2.48 per mil) due to evaporation. Thus it is possible to use stable isotopes of oxygen and hydrogen to separate canal water from precipitation and groundwater as a source of freshwater into the bay. Other geochemical constituents, such as calcium and magnesium are being investigated to further discern between the sources of canal water, rainfall and fresh groundwater. Both the stable isotopes and ion values will be placed in a mixing model to quantify and discern the dominant sources of freshwater into the Bay in both time and space.
Information Compendium on Nonflammable Hydraulic Fluid and Design Requirements for Its Adoption
1990-02-01
Titration. D 892 - Foaming Characteristics of Lubricating Oils. D 1744 - Water in Liquid Petroleum Products by Karl Fischer Reagent. A-2 MI L- H-UrnX... Method Standard 791C, Method 5308. MIL-H-6083 and MIL-H-46170 are tested at 121°C; NFH is tested at 1350C. * MIL-H-6083 and MIL-H-46170 are tested with...demonstrated such improved fire resistance that they were termed nonflammable hydraulic fluids. A new test method for measuring flame/fire propagation
Thermal degradation products from PVC film in food-wrapping operations.
Boettner, E A; Ball, G L
1980-07-01
Thermal degradation products of polyvinyl chloride (PVC) food-wrap films were studied under simulated supermarket conditons using a commercial wrapping machine with either a hot wire or a cool rod cutting device. A sampling hood was constructed around the wire/rod to confine and allow collection of thermal degradation products produced. Compounds analyzed and normal concentration ranges found included hydrogen chloride (1-10 micrograms per cut), plasticizer (1-50 micrograms per cut), benzene and toluene (each < 5-20 ng per cut), acrolein (25-150 ng per cut), and carbon monoxide (2-4 micrograms per cut) using the hot wire. Room air samples, collected during hot-wire cutting without the sampling hood, had < 0.25 ppm hydrogen chloride. Using the cool-rod cutting device hydrogen chloride, benzene, and toluene were not detected. Plasticizer was detected (25-86 micrograms per cut) using the cool rod.
Scanner baseliner monitoring and control in high volume manufacturing
NASA Astrophysics Data System (ADS)
Samudrala, Pavan; Chung, Woong Jae; Aung, Nyan; Subramany, Lokesh; Gao, Haiyong; Gomez, Juan-Manuel
2016-03-01
We analyze performance of different customized models on baseliner overlay data and demonstrate the reduction in overlay residuals by ~10%. Smart Sampling sets were assessed and compared with the full wafer measurements. We found that performance of the grid can still be maintained by going to one-third of total sampling points, while reducing metrology time by 60%. We also demonstrate the feasibility of achieving time to time matching using scanner fleet manager and thus identify the tool drifts even when the tool monitoring controls are within spec limits. We also explore the scanner feedback constant variation with illumination sources.
Dexterity testing of chemical-defense gloves. Technical report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robinette, K.M.; Ervin; Zehner, G.F.
1986-05-01
Chemical-defense gloves (12.5-mil Epichlorohydron/Butyl, 14-mil Epichlorohydron/Butyl, and 7-mil Butyl with Nomex overgloves) were subjected to four dexterity tests (O'Connor Finger Dexterity Test, Pennsylvania Bi-Manual Worksample-Assembly, Minnesota Rate of Manipulation Turning, and the Crawford Small Test). Results indicated that subjects performances were most impaired by the 7-mil Butyl with Nomex overglove. Though differences between the other three gloved conditions were not always statistically significant, subjects performed silghtly better while wearing the Epichlorohydron/Butyl gloves, no matter which thickness, than they did while wearing the 15-mil butyl gloves. High negative correlation between anthropometry and gloved tests scores of subjects suggested that poor glovemore » fit may also have affected subjects performances.« less
Technical Services Cost Studies in ARL Libraries. SPEC Kit 125.
ERIC Educational Resources Information Center
Hoerman, Heidi Lee
Based on a survey of Association of Research Libraries (ARL) member libraries in February 1986, this kit is designed to illustrate a wide range of alternative approaches to analyzing the costs of technical services. The kit consists of the following unedited primary-source documents: (1) SPEC Technical Services Costs Survey (Three-Year Update)…
United States Air Force Analysis Extract AFSC 2A6X4 Aircraft Fuel Systems (Active Duty)
2001-02-01
8217AFOMS (AETC) Randolph AFB TX’ V0226 Spec tools/equip use/oper - Rollers or Stitchers ACTIVE...8217AFOMS (AETC) Randolph AFB TX’ V0226 Spec tools/equip use/oper - Rollers or Stitchers ...equip use/oper - Rollers or Stitchers USAFE AETC PACAF AFSOC ACC AMC AFMC
Preparation and Presentation of the Library Budget. SPEC Kit 32.
ERIC Educational Resources Information Center
Association of Research Libraries, Washington, DC. Office of Management Studies.
This kit on the preparation and presentation of the library budget in Association of Research Libraries (ARL) institutions contains a concise summary of the results of a 1977 member survey on budget preparation and eight related primary source documents. The summary of the Systems and Procedures Exchange Center (SPEC) survey focuses on types of…
Organization Charts in ARL Libraries. SPEC Kit #170.
ERIC Educational Resources Information Center
Association of Research Libraries, Washington, DC. Office of Management Studies.
This kit is based on a review of the organization charts of 71 member libraries of the Association of Research Libraries (ARL) gathered in January 1991, compared with an earlier SPEC Kit published in 1986, and contains charts of 29 of the libraries. A summary of the chart analyses presents information about the titles of library directors,…
Evaluation of the Alexon-Trend ProSpecT Campylobacter Microplate Assay
Tolcin, Rita; LaSalvia, Margaret M.; Kirkley, Barbara A.; Vetter, Emily A.; Cockerill, Franklin R.; Procop, Gary W.
2000-01-01
We evaluated stool specimens known to contain or be free of Campylobacter by traditional culture, using the ProSpecT Campylobacter microplate assay (Alexon-Trend, Ramsey, Minn.). This rapid enzyme immunoassay for the detection of Campylobacter-specific antigens demonstrated 96% sensitivity and 99% specificity and is an acceptable alternative method of Campylobacter detection. PMID:11015419
Access Services: Organization and Management. SPEC Kit #179.
ERIC Educational Resources Information Center
Steel, Virginia, Comp.
This Systems and Exchange Center (SPEC) kit begins with a summary by Virginia Steel of the findings of a survey of Association of Research Libraries (ARL) member libraries that was conducted in 1991 to determine the prevalence of the organizational model of access services--i.e., a department or division responsible for the services and operations…
46 CFR 160.026-6 - Sampling, inspection, and tests of production lots.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Bacteriological limits and salt content MIL-W-15117 and U.S. Public Health “Drinking Water Standards.” (e) Lot..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Water, Emergency Drinking (In... lots. (a) General. Containers of emergency drinking water must be tested in accordance with the...
46 CFR 160.026-6 - Sampling, inspection, and tests of production lots.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Bacteriological limits and salt content MIL-W-15117 and U.S. Public Health “Drinking Water Standards.” (e) Lot..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Water, Emergency Drinking (In... lots. (a) General. Containers of emergency drinking water must be tested in accordance with the...
46 CFR 160.026-6 - Sampling, inspection, and tests of production lots.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Bacteriological limits and salt content MIL-W-15117 and U.S. Public Health “Drinking Water Standards.” (e) Lot..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Water, Emergency Drinking (In... lots. (a) General. Containers of emergency drinking water must be tested in accordance with the...
46 CFR 160.026-6 - Sampling, inspection, and tests of production lots.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Bacteriological limits and salt content MIL-W-15117 and U.S. Public Health “Drinking Water Standards.” (e) Lot..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Water, Emergency Drinking (In... lots. (a) General. Containers of emergency drinking water must be tested in accordance with the...
46 CFR 160.026-6 - Sampling, inspection, and tests of production lots.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Bacteriological limits and salt content MIL-W-15117 and U.S. Public Health “Drinking Water Standards.” (e) Lot..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Water, Emergency Drinking (In... lots. (a) General. Containers of emergency drinking water must be tested in accordance with the...
Code of Federal Regulations, 2010 CFR
2010-07-01
...://www.dtic.mil/whs/directives/corres/pdf/520008r.pdf. 10 Available athttp://www.dtic.mil/whs/directives... hostile acts or demonstrated hostile intent. 11 Available athttp://www.dtic.mil/whs/directives/corres/pdf/110022p.pdf. (D) Documentation of individual training covering weapons familiarization and qualification...
PROPOSED REVISION OF MIL-H-81019, HYDRAULIC FLUID, PETROLEUM BASE, ULTRA-LOW TEMPERATURE,
81019 in line with that of the fluid currently being supplied under MIL -H-5606B. (Author)...An investigation was conducted to revise specification requirements and test methods which would bring the quality of the fluid supplied under MIL -H
DC Voltage Interface Standards for Naval Applications
2015-06-24
norbert.doerry@navy.mil Dr. John Amy Naval Sea Systems Command United States Navy Washington DC , USA john.amy@navy.mil Abstract—. MIL-STD-1399...standards have been established for DC interfaces on U.S. naval surface ships. This paper provides recommendations for specific standard DC
NASA Astrophysics Data System (ADS)
Zadehahmadi, Farnaz; Tangestaninejad, Shahram; Moghadam, Majid; Mirkhani, Valiollah; Mohammadpoor-Baltork, Iraj; Khosropour, Ahmad R.; Kardanpour, Reihaneh
2014-10-01
In the present work, chloromethylated MIL-101(Cr) modified with imidazole, Im-MIL-101, was applied as a support for immobilizing of tetraphenylporphyrinatomangenese(III) chloride. The imidazole-bound MIL-101, Im-MIL-101, not only used as support for immobilization of manganese porphyrin but also applied as a heterogeneous axial base. The Mn(TPP)Cl@Im-MIL-101 catalyst was characterized by UV-vis, FT-IR, X-ray diffraction (XRD), N2 adsorption, field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray (EDX), elemental analysis and inductively coupled plasma (ICP) methods. The catalytic activity of this new catalytic system was investigated in the alkene epoxidation and alkane hydroxylation using NaIO4 as an oxidant in CH3CN/H2O at room temperature. This heterogeneous catalyst is highly efficient, stable and reusable in the oxidation of hydrocarbons.
NASA Tech Briefs, November 2004
NASA Technical Reports Server (NTRS)
2004-01-01
Topics include: Multifunction Imaging and Spectroscopic Instrument; Position-Finding Instrument Built Around a Magnetometer; Improved Measurement of Dispersion in an Optical Fiber; Probe for Sampling of Interstitial Fluid From Bone; Neuropsychological Testing of Astronauts; Method of Calibration for a Large Cathetometer System; Four-Channel PC/104 MIL-STD-1553 Circuit Board; Improved Method of Locating Defects in Wiring Insulation; Strobe Traffic Lights Warn of Approaching Emergency Vehicles; Improved Timing Scheme for Spaceborne Precipitation Radar; Concept for Multiple-Access Free-Space Laser Communications; Variable Shadow Screens for Imaging Optical Devices; Verifying Diagnostic Software; Initial Processing of Infrared Spectral Data; Activity-Centric Approach to Distributed Programming; Controlling Distributed Planning; New Material for Surface-Enhanced Raman Spectroscopy; Treated Carbon Nanofibers for Storing Energy in Aqueous KOH; Advanced Infant Car Seat Would Increase Highway Safety; Development of Biomorphic Flyers; Second-Generation Six-Limbed Experimental Robot; Miniature Linear Actuator for Small Spacecraft; Process for Making Single-Domain Magnetite Crystals; A New Process for Fabricating Random Silicon Nanotips; Resin-Transfer-Molding of a Tool Face; Improved Phase-Mask Fabrication of Fiber Bragg Gratings; Tool for Insertion of a Fiber-Optic Terminus in a Connector; Nanofluidic Size-Exclusion Chromatograph; Lightweight, Low-CTE Tubes Made From Biaxially Oriented LCPs; Using Redundancy To Reduce Errors in Magnetometer Readings; Compact Instrument for Measuring Profile of a Light Beam; Multilayer Dielectric Transmissive Optical Phase Modulator; Second-Generation Multi-Angle Imaging Spectroradiometer; Real-Time Adaptive Color Segmentation by Neural Networks; Research and Development in Optical Communications; Tests of Multibeam Scintillation Mitigation on Laser Uplinks; and Spaceborne Infrared Atmospheric Sounder.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Internet at http://www.dtic.mil/whs/directives/corres/pdf/300005p.pdf. 2 Copies available on the Internet at http://www.dtic.mil/whs/directives/corres/pdf/220502p.pdf. 3 Copies available on the Internet at http://www.dtic.mil/whs/directives/corres/pdf/231008p.pdf. ...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Internet at http://www.dtic.mil/whs/directives/corres/pdf/300005p.pdf. 2 Copies available on the Internet at http://www.dtic.mil/whs/directives/corres/pdf/220502p.pdf. 3 Copies available on the Internet at http://www.dtic.mil/whs/directives/corres/pdf/231008p.pdf. ...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Internet at http://www.dtic.mil/whs/directives/corres/pdf/300005p.pdf. 2 Copies available on the Internet at http://www.dtic.mil/whs/directives/corres/pdf/220502p.pdf. 3 Copies available on the Internet at http://www.dtic.mil/whs/directives/corres/pdf/231008p.pdf. ...
48 CFR 252.246-7001 - Warranty of data.
Code of Federal Regulations, 2011 CFR
2011-10-01
... calibration procedures under MIL-T-31000, General Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data Packages, Supp 1, or drawings and associated... Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data...
48 CFR 252.246-7001 - Warranty of data.
Code of Federal Regulations, 2014 CFR
2014-10-01
... calibration procedures under MIL-T-31000, General Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data Packages, Supp 1, or drawings and associated... Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data...
48 CFR 252.246-7001 - Warranty of data.
Code of Federal Regulations, 2013 CFR
2013-10-01
... calibration procedures under MIL-T-31000, General Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data Packages, Supp 1, or drawings and associated... Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data...
48 CFR 252.246-7001 - Warranty of data.
Code of Federal Regulations, 2010 CFR
2010-10-01
... calibration procedures under MIL-T-31000, General Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data Packages, Supp 1, or drawings and associated... Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data...
48 CFR 252.246-7001 - Warranty of data.
Code of Federal Regulations, 2012 CFR
2012-10-01
... calibration procedures under MIL-T-31000, General Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data Packages, Supp 1, or drawings and associated... Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data...
High Power Amplifier and Power Supply
NASA Technical Reports Server (NTRS)
Duong, Johnny; Stride, Scot; Harvey, Wayne; Haque, Inam; Packard, Newton; Ng, Quintin; Ispirian, Julie Y.; Waian, Christopher; Janes, Drew
2008-01-01
A document discusses the creation of a high-voltage power supply (HVPS) that is able to contain voltages up to -20 kV, keep electrical field strengths to below 200 V/mil (approximately equal to 7.87 kV/mm), and can provide a 200-nanosecond rise/fall time focus modulator swinging between cathode potential of 16.3 kV and -19.3 kV. This HVPS can protect the 95-GHz, pulsed extended interaction klystron (EIK) from arcs/discharges from all sources, including those from within the EIK fs vacuum envelope. This innovation has a multi-winding pulse transformer design, which uses new winding techniques to provide the same delays and rise/fall times (less than 10 nanoseconds) at different potential levels ranging from -20 kV to -16 kV. Another feature involves a high-voltage printed-wiring board that was corona-free at -20 kV DC with a 3- kV AC swing. The corona-free multilayer high-voltage board is used to simulate fields of less than 200 V/mil (approximately equal to 7.87 kV/mm) at 20 kV DC. Drive techniques for the modulator FETs (field-effect transistors) (four to 10 in a series) were created to change states (3,000-V swing) without abrupt steps, while still maintaining required delays and transition times. The packing scheme includes a potting mold to house a ten-stage modulator in the space that, in the past, only housed a four-stage modulator. Problems keeping heat down were solved using aluminum oxide substrate in the high-voltage section to limit temperature rise to less than 10 while withstanding -20 kV DC voltage and remaining corona-free.
Integrated soldier power and data system (ISPDS)
NASA Astrophysics Data System (ADS)
Ostroumov, Roman; Forrester, Thomas; Lee, Kang; Stephens, Robert; Lai, Anthony; Zahzah, Mohamad
2014-06-01
Physical Optics Corporation (POC) developed the body-worn Integrated Soldier Power and Data System (ISPDS), a configurable node for plug-in wired or wireless server/client or peer-to-peer computing with accommodations for power, sensor I/O interfaces, and energy harvesting. The enabling technology increases the efficacy of uniformed personnel and first responders and provides an option for reducing force structure associated with the need for hardware network infrastructure to enable a mobile digital communications architecture for dismounted troops. The ISPDS system addresses the DoD's need for an "intelligent" power control system in an effort to increase mission duration and maximize the first responders and warfighter's effectiveness without concern for the available energy resources (i.e., batteries). ISPDS maximizes durability and survivability, assesses influences that affect performance, and provides the network backbone and mobile node hardware. POC is producing two vest-integrated variants, one each for the U.S. Army PEO Ground Soldier and the Air Soldier, with each including state-of-the-art low-profile and robust wearable connectors, cabling, and harnesses, and an integrated low-profile power manager and conformal battery for data and power distribution. The innovative intelligent power controller (IPC), in the form of the ISPDS firmware and power sensing and control electronics, will enable ISPDS to optimize power levels both automatically and in accordance with manually set preferences. The IPC module is power dense and efficient, and adaptively provides lossless transfer of available harvested photovoltaic energy to the battery. The integrated systems were tested for suitable electrical, electromagnetic interference (EMI), and environmental performance as outlined in military standards such as MIL-STD- 810G and MIL STD-461F.
NASA Astrophysics Data System (ADS)
Lerner, M. I.; Bakina, O. V.; Pervikov, A. V.; Glazkova, E. A.; Lozhkomoev, A. S.; Vorozhtsov, A. B.
2018-05-01
X-ray phase analysis, transmission electron microscopy, and X-ray microanalysis were used to examine the structural-phase states of Fe-Cu and Fe-Ag bimetallic nanoparticles. The nanoparticles were obtained by the electric explosion of two twisted metal wires in argon atmosphere. It was demonstrated that the nanoparticles have the structure of Janus particles. Presence of the Janus particle structure in the samples indicates formation of binary melt under conditions of combined electric explosion of two wires. Phases based on supersaturated solid solutions were not found in the examined samples. The data obtained allow arguing that it is possible to achieve uniform mixing of the two-wire explosion products under the described experiment conditions.
NASA Astrophysics Data System (ADS)
Lerner, M. I.; Bakina, O. V.; Pervikov, A. V.; Glazkova, E. A.; Lozhkomoev, A. S.; Vorozhtsov, A. B.
2018-05-01
X-ray phase analysis, transmission electron microscopy, and X-ray microanalysis were used to examine the structural-phase states of Fe-Cu and Fe-Ag bimetallic nanoparticles. The nanoparticles were obtained by the electric explosion of two twisted metal wires in argon atmosphere. It was demonstrated that the nanoparticles have the structure of Janus particles. Presence of the Janus particle structure in the samples indicates formation of binary melt under conditions of combined electric explosion of two wires. Phases based on supersaturated solid solutions were not found in the examined samples. The data obtained allow arguing that it is possible to achieve uniform mixing of the two-wire explosion products under the described experiment conditions.
Delta14 CO2 Atmospheric Record from Schauinsland, Germany
Levin, Ingeborg [Institut fur Umweltphysik, University of Heidelberg, Heidelberg, Germany; Kromer, Bernd [Institut fur Umweltphysik, University of Heidelberg, Heidelberg, Germany
1997-01-01
All air samples at Schauinsland have been collected from a ventilated intake stack approximately 7m above the ground. Bi-weekly integrated CO2 samples from about 15-20 m3 of air have been continuously collected by dynamic quantitative absorption in carbonate-free sodium hydroxide (NaOH) solution. Air has been pumped through a rotating glass tube filled with a packed bed of Raschig rings (hard glass) to enlarge the surface of the absorbing NaOH solution (200 ml of 4 normal NaOH). The CO2 absorption is quantitative and samples represent mean values of 10 days to 2 weeks. In the laboratory, the samples are extracted from the NaOH solution in a vacuum system by adding hydrochloric or sulfuric acid. 13C analyses of the CO2 are by mass spectrometry and 14C analyses are by high precision proportional counting, after purification of the CO2 sample over charcoal (Schoch et al. 1980, Kromer and Münnich 1992). δ13C values are given relative to the V-PDB standard (Hut 1987) with the overall precision of a single analysis reported to be +/- 0.15 per mil (Levin and Kromer 1997). δ14C data are given relative to the NIST oxalic acid activity corrected for decay (Stuiver and Polach 1977) with the precision of a single δ14C measurement reported to be +/- 3-5 per mil (Levin and Kromer 1997).
Radiating dipole model of interference induced in spacecraft circuitry by surface discharges
NASA Technical Reports Server (NTRS)
Metz, R. N.
1984-01-01
Spacecraft in geosynchronous orbit can be charged electrically to high voltages by interaction with the space plasma. Differential charging of spacecraft surfaces leads to arc and blowoff discharging. The discharges are thought to upset interior, computer-level circuitry. In addition to capacitive or electrostatic effects, significant inductive and less significant radiative effects of these discharges exist and can be modeled in a dipole approximation. Flight measurements suggest source frequencies of 5 to 50 MHz. Laboratory tests indicate source current strengths of several amperes. Electrical and magnetic fields at distances of many centimeters from such sources can be as large as tens of volts per meter and meter squared, respectively. Estimates of field attenuation by spacecraft walls and structures suggest that interior fields may be appreciable if electromagnetic shielding is much thinner than about 0.025 mm (1 mil). Pickup of such fields by wires and cables interconnecting circuit components could be a source of interference signals of several volts amplitude.
Oxidation Kinetics of a NiPtTi High Temperature Shape Memory Alloy
NASA Technical Reports Server (NTRS)
Smialek, James L.; Humphrey, Donald L.; Noebe, Ronald D.
2007-01-01
A high temperature shape memory alloy (HTSMA), Ni30Pt50Ti, with an M(sub s) near 600 C, was isothermally oxidized in air for 100 hr over the temperature range of 500 to 900 C. Parabolic kinetics were confirmed by log-log and parabolic plots and showed no indication of fast transient oxidation. The overall behavior could be best described by the Arrhenius relationship: k(sub p) = 1.64 x 10(exp 12)[(-250 kJ/mole)/RT] mg(sup 2)/cm(sup 4)hr. This is about a factor of 4 reduction compared to values measured here for a binary Ni47Ti commercial SMA. The activation energy agreed with most literature values for TiO2 scale growth measured for elemental Ti and other NiTi alloys. Assuming uniform alloy depletion of a 20 mil (0.5 mm) dia. HTSMA wire, approx. 1 percent Ti reduction is predicted after 20,000 hr oxidation at 500 C, but becomes much more serious at higher temperatures.
46 CFR 160.026-1 - Applicable specifications and standard.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Water, Emergency Drinking (In... water is packed, form a part of this subpart: (1) Military specifications: MIL-L-7178—Lacquer; cellulose nitrate, gloss for aircraft use. MIL-E-15090—Enamel, equipment, light-gray (Formula No. 111). MIL-W-15117...
U.S. Air Force Aircrew Flight Protective Eyewear Program
2013-02-01
MIL-DTL-32000), fire - resistant hydraulic fluid (MIL-PRF-46170), petroleum-based hydraulic fluid (MIL-PRF-6083), gasoline (87% octane), motor oil...UPLC installed. ABRASION FPE spectacles and goggles shall maximize resistance to scratching/ abrasion to minimize interference with vision...Visual Area ................................................................................. 2 3.0 BALLISTIC AND IMPACT RESISTANCE : BALLISTIC
32 CFR 701.102 - Online resources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... online Web site (http://www.privacy.navy.mil). This Web site supplements this subpart and subpart G. It...) Web site (http://www.doncio.navy.mil). This Web site provides detailed guidance on PIAs. (c) DOD's PA Web site (http://www.defenselink.mil/privacy). This Web site is an excellent resource that contains a...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-08
... calibration procedures under MIL-T-31000, General Specification for Technical Data Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data Packages, Supp 1, or drawings and associated... Packages, Amendment 1, or MIL-T-47500, General Specification for Technical Data Packages, Supp 1, or...
NASA Technical Reports Server (NTRS)
Cataldo, Giuseppe; Moseley, S. H.; Hsieh, W.-T.; Huang, W,-C,; Stevenson, T. R.; Wollak, E. J.
2012-01-01
Micro-Spec (u-Spec) is a high-performance spectrometer working in the 250-700-micrometer wavelength range, whose modules use low-loss superconducting microstrip transmission lines on a single 4-inch-diameter silicon wafer. Creating the required phase delays in transmission lines rather than free space allows such an instrument to have, in principle, the performance of a meter-scale grating spectrometer. Such a dramatic size reduction enables classes of instruments for space that would be impossible with conventional technologies. This technology can dramatically enhance the long-wavelength capability of the space infrared telescope for cosmology and astrophysics SPICA. u-Spec is analogous to a grating spectrometer. The phase retardation generated by the reflection from the grating grooves is instead produced by propagation through a transmission line. The power received by a broadband antenna is progressively divided by binary microstrip power dividers, and the required phase delays are generated by different lengths of microstrip transmission lines. by arranging these outputs along a circular focal surface, the analog of a Rowland spectrometer can he created. The procedure to optimize the Micro-Spec design is based on the stigmatization and minimization of the light path function in a two-dimensional hounded region, which results in an optimized geometry arrangement with three stigmatic points. In addition, in order to optimize the overall efficiency of the instrument, the emitters are directed to the center of the focal surface. The electric field amplitude and phase as well as the power transmitted and absorbed throughout the region are analyzed. Measurements are planned in late summer to validate the designs.
2013-01-22
hydrofluoric acid in the hydro- thermal synthesis of MIL-101 MOF, and employed an optimized TMAOH/Cr(NO3)3/TPA/H2O (0.25/1/1/280) alkaline medium.41 MOF...identical to those of as-synthesized, parent MIL-101. This demonstrates that the framework integrity of MIL-101 was retained after both thermal water...Materials & Interfaces Research Article dx.doi.org/10.1021/am302359b | ACS Appl. Mater. Interfaces 2013, 5, 1269−12781272 of most zeolites or silicas
Testing of Fire Fighting Foam.
1980-11-01
for Fresh and Sea Water ( MIL - F - 24385 ); -(C) Underwriters Laboratories Inc. S andard for Air Foam Equipment and Liquid Con- centrates (UL162);4D...C. Test Facilities 6 D. Test Procedures 7 III. Results of Tests A. FRN-1007 33 B. MIL - F - 24385 34 C. UL 162 34 D. O- F -555C 35 E. Foam Quality 35 IV...1 gpm) H N-heptane in. inch (25.4 mm = 1 in.) ipm liters per minute M Motor Octane Rating MIL MIL - F - 24385 Test Method NFPA National Fire Protection
2016-05-01
measurements for distilled mustard (HD) and non- welded high-density polyethylene (HDPE) at 120 °F were completed for thicknesses of 20–80 mil for...extrapolation to the ~250 mil container thickness. A Fick’s law extrapolation inferred a breakthrough time of 10–11 days for the 250 mil non- welded HDPE at...8 3.2 Permeation Results for 20 mil HDPE at 100 °F: Welded ................................10 3.2.1 Confirmation Test: Welded
Engineering and Design Criteria for Navy Facilities.
1987-11-20
ELECTRIC, AND STANDS, GRIDDLE MI L-R-2357G (2) OCT. 1980 G INT AMD 3 RANGE, GAS, (CCMMERCIAL) HEAVY DUTY MI L-D-2467F JUL. 1987 E MAR. 1974. DOUGH ...3420D PACKAGING MATERIALS, VOLATILE CORROSION !NHIBITOR, TREATED, OPAQUE d~~ .; . . . .p -. % . % " - " MIL-D-3886F NOV i986 E P E 8 978 DOUGH ...10388G APR. 1982 PIPE FITTING, ONE OR MORE ENDS GPOVED MIL-S-1 1183E JUN. 1977 SCALE, DIAL AND BEAM INDICATING, BAKERS, DOUGH PIECE CHECK I NG MIL-M
NASA Astrophysics Data System (ADS)
Borglin, Johan; Guldbrand, Stina; Evenbratt, Hanne; Kirejev, Vladimir; Grönbeck, Henrik; Ericson, Marica B.
2015-12-01
Gold nanoparticles can be visualized in far-field multiphoton laser-scanning microscopy (MPM) based on the phenomena of multiphoton induced luminescence (MIL). This is of interest for biomedical applications, e.g., for cancer diagnostics, as MPM allows for working in the near-infrared (NIR) optical window of tissue. It is well known that the aggregation of particles causes a redshift of the plasmon resonance, but its implications for MIL applying far-field MPM should be further exploited. Here, we explore MIL from 10 nm gold nanospheres that are chemically deposited on glass substrates in controlled coverage gradients using MPM operating in NIR range. The substrates enable studies of MIL as a function of inter-particle distance and clustering. It was shown that MIL was only detected from areas on the substrates where the particle spacing was less than one particle diameter, or where the particles have aggregated. The results are interpreted in the context that the underlying physical phenomenon of MIL is a sequential two-photon absorption process, where the first event is driven by the plasmon resonance. It is evident that gold nanospheres in this size range have to be closely spaced or clustered to exhibit detectable MIL using far-field MPM operating in the NIR region.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borglin, Johan; Department of Physics, University of Gothenburg, Kemivägen 10, 412 96 Gothenburg; Guldbrand, Stina
Gold nanoparticles can be visualized in far-field multiphoton laser-scanning microscopy (MPM) based on the phenomena of multiphoton induced luminescence (MIL). This is of interest for biomedical applications, e.g., for cancer diagnostics, as MPM allows for working in the near-infrared (NIR) optical window of tissue. It is well known that the aggregation of particles causes a redshift of the plasmon resonance, but its implications for MIL applying far-field MPM should be further exploited. Here, we explore MIL from 10 nm gold nanospheres that are chemically deposited on glass substrates in controlled coverage gradients using MPM operating in NIR range. The substrates enablemore » studies of MIL as a function of inter-particle distance and clustering. It was shown that MIL was only detected from areas on the substrates where the particle spacing was less than one particle diameter, or where the particles have aggregated. The results are interpreted in the context that the underlying physical phenomenon of MIL is a sequential two-photon absorption process, where the first event is driven by the plasmon resonance. It is evident that gold nanospheres in this size range have to be closely spaced or clustered to exhibit detectable MIL using far-field MPM operating in the NIR region.« less
Tomás-Sábado, Joaquín; Villavicencio-Chávez, Christian; Monforte-Royo, Cristina; Guerrero-Torrelles, Mariona; Fegg, Martin Johannes; Balaguer, Albert
2015-12-01
Meaning in life (MiL) is a construct that varies across individuals, situations, cultures, and countries, and protects against emotional distress at the end of life. To examine MiL in inpatients with advanced cancer from Barcelona, Spain, and to compare the findings with those obtained in German and Swiss samples. This was a cross-sectional study in which the Schedule for Meaning in Life Evaluation (SMiLE) was administered. The SMiLE asks respondents to list individual areas that give meaning in their lives and then to rate their current level of importance and satisfaction with the listed areas. A total of 101 inpatients completed the SMiLE. The Index of Satisfaction was 76.8 ± 21.1, the Index of Weighting was 88.0 ± 13.0, and the Index of Weighted Satisfaction was 76.9 ± 20.7. Family, partnership, well-being, and friends were the four areas listed by the largest proportion of Spanish patients. Compared with the German sample, Spanish patients were more likely to list well-being (P < 0.01) and pleasure (P < 0.05) and less likely to list animals/nature, leisure time, and finances (P < 0.01). With respect to their Swiss counterparts, Spanish patients were more likely to list health (P < 0.01) and less likely to list friends, leisure time, animals/nature, and finances (P < 0.01). Differences were identified in the areas of MiL listed by the participants according to country of origin. Compared with their German and Swiss counterparts, the Spanish patients listed more areas involving interpersonal relationships. Interpersonal relationships, at both the family and wider social level, are reported to be the areas that give the greatest MiL to these patients. These aspects, therefore, should be considered when drawing up care plans designed to help patients achieve the maximum possible comfort and quality of life. Copyright © 2015 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.
Verifiable Task Assignment and Scheduling Controller
2017-07-01
15 Figure 8. Summary of results for NASA -TLX overall workload and individual...using the NASA Task Load Index ( NASA -TLX; Hart & Staveland, 1988), which was completed using a computerized version of the questionnaire. The...filled out the NASA -TLX. Then prior to the second trial, participants were trained on how to use SPEC. SPEC training consisted of: an explanation of the
ERIC Educational Resources Information Center
Soete, George J.
The problem of preserving digital information and the strategies that are and might be employed to address it are the focus of this fifth issue of "Transforming Libraries." Twenty-one individuals involved at the technical or policy level in developing strategies for preserving digital information were interviewed. There is consensus on a…
ERIC Educational Resources Information Center
Ford, Alan R.; Burns, William A.; Reeve, Scott W.
2004-01-01
A version of the classic gas phase infrared experiment was developed for students at Arkansas State University based on the shortcomings of the rotationally resolved infrared experiment. Chem Spec II is a noncommercial Windows-based software package developed to aid in the potentially complicated problem of assigning quantum numbers to observed…
30 CFR 250.806 - Safety and pollution prevention equipment quality assurance requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Gas Operations (as incorporated by reference in § 250.198); and (ii) API Spec Q1, Specification for... in § 250.198). (3) All SSV's and USV's must meet the technical specifications of API Spec 6A and 6AV1. All SSSVs must meet the technical specifications of API Specification 14A (as incorporated by...
30 CFR 250.806 - Safety and pollution prevention equipment quality assurance requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Gas Operations (as incorporated by reference in § 250.198); and (ii) API Spec Q1, Specification for... in § 250.198). (3) All SSV's and USV's must meet the technical specifications of API Spec 6A and 6AV1. All SSSVs must meet the technical specifications of API Specification 14A (as incorporated by...
30 CFR 250.806 - Safety and pollution prevention equipment quality assurance requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Gas Operations (as incorporated by reference in § 250.198); and (ii) API Spec Q1, Specification for... in § 250.198). (3) All SSV's and USV's must meet the technical specifications of API Spec 6A and 6AV1. All SSSVs must meet the technical specifications of API Specification 14A (as incorporated by...
Textile Fingerprinting for Dismount Analysis in the Visible, Near, and Shortwave Infrared Domain
2014-03-01
Laboratory setup of reflectance data collection. The green, 100% cotton shirt sample, contact probe, and black calibration panel used are labeled...32 3.2 100 Instances of Cotton Reflectance from ASD FieldSpec ® 3 Hi-Res Spectroradiometer using a contact probe, with a black reflectance panel as...eight a-class colors. The solid vertical black line represents the wavelength selected as a feature (430nm, 481nm, 530nm, 588nm
Role of the C-terminus in the activity, conformation, and stability of interleukin-6.
Ward, L. D.; Hammacher, A.; Zhang, J. G.; Weinstock, J.; Yasukawa, K.; Morton, C. J.; Norton, R. S.; Simpson, R. J.
1993-01-01
Two murine interleukin-6 (mIL-6) variants were constructed using the polymerase chain reaction (PCR), one lacking the last five residues (183-187) at the C-terminus (pMC5) and another with the last five residues of mIL-6 substituted by the corresponding residues of human IL-6 (pMC5H). The growth stimulatory activity of pMC5 on the mouse hybridoma cell line 7TD1 was < 0.05% of mIL-6, whereas pMC5H and mIL-6 were equipotent. The loss of biological activity of pMC5 correlated with its negligible receptor binding affinity on 7TD1 cells, while the binding of pMC5H was comparable to that of mIL-6. Both pMC5 and pMC5H, like mIL-6, failed to interact with recombinant soluble human IL-6 receptor when assayed by surface plasmon resonance-based biosensor analysis. These studies suggest that the C-terminal seven amino acids of human IL-6, alone, do not define species specificity for receptor binding. A variety of biophysical techniques, as well as the binding of a conformational-specific monoclonal antibody, indicated that the global fold of the mIL-6 variants was similar to that of mIL-6, although small changes in the NMR spectra, particularly for pMC5, were observed. Some of these changes involved residues widely separated in the primary structure. For instance, interactions involving Tyr-22 were influenced by the C-terminal amino acids suggesting that the N- and C-termini of mIL-6 are in close proximity. Equilibrium unfolding experiments indicated that pMC5 was 0.8 kcal/mol less stable than mIL-6, whereas pMC5H was 1.4 kcal/mol more stable. These studies emphasize the structural importance of the C-terminal amino acids of IL-6 and suggest that truncation or mutation of this region could lead to small but significant alterations in other regions of the molecule. PMID:8401231
Synthesis and magnetic properties of bundled and dispersed Co{sub 3}O{sub 4} nanowires
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, B.B.; Wang, P.F.; Xu, J.C.
Highlights: • Co{sub 3}O{sub 4} nanowires possessed the same diameter and the different interwires distance. • All samples possessed antiferromagnetism and superparamagnetism at high temperature. • The exchange bias effect was observed at low temperature. • The surface spin coupling restrained the surface effect of magnetic nanostructures. - Abstract: The magnetic Co{sub 3}O{sub 4} nanowires were synthesized using the templates of SBA-15, and then the well-dispersed nanowires (D-wires) were separated from the bundled ordered nanowires (B-wires) with the centrifugal technique. TEM images indicated that D-wires were highly dispersed Co{sub 3}O{sub 4} nanowires and B-wires existed in bundles. All samples possessedmore » the antiferromagnetism and superparamagnetism at high temperature. After revealing the intrinsic magnetic properties of Co{sub 3}O{sub 4} nanowires with D-wires, the magnetic behavior of B-wires was discussed in detail, and then the magnetic interaction between neighboring nanowires could be deduced. The exchange bias effect from the body Co{sub 3}O{sub 4} antiferromagnetism and surface ferromagnetism was observed at low temperature. The magnetization of B-wires was higher than that of D-wires, which was attributed to the constraint of the surface spin coupling between the neighboring nanowires to the surface affect of nanostructures.« less
Flash Point Performance Evaluation
2014-03-01
ACRONYMS AND ABBREVIATIONS Acronym Definition ASTM ASTM International, consensus standards and specifications B20 Biodiesel containing 20% FAME...HRJ-1 is a sample of HEFA SPK [10] that is used to blend semi-synthetic jet fuel. The B20-1 is a sample of a 20% biodiesel blend [20]. The US Army...Standard Specification for Diesel Fuel Oil, Biodiesel Blend (B6 to B20), ASTM International, W. Conshohocken, PA 21. MIL-DTL-25576E the Detail
Code of Federal Regulations, 2014 CFR
2014-07-01
...,” (available at http://www.dtic.mil/whs/directives/corres/pdf/520507p.pdf). Classified contract. As defined in... Military and Associated Terms” (available at http://www.dtic.mil/doctrine/new_pubs/jp1_02.pdf). Company. As..., “Joint Communication System” (available at http://www.dtic.mil/doctrine/new_pubs/jp6_0.pdf). Contractor...
32 CFR 117.55 - Responsibilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
...))” (available at http://www.dtic.mil/whs/directives/corres/pdf/514301p.pdf) and DoD Instruction 5220.22, “National Industrial Security Program” (see http://www.dtic.mil/whs/directives/corres/pdf/522022p.pdf): (1...://www.dtic.mil/whs/directives/corres/pdf/522022p.pdf). (1) Make FOCI determinations on a case-by-case...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Copies available on the Internet at http://www.dtic.mil/whs/directives/corres/pdf/100013p.pdf. (2) Non... Internet at http://www.dtic.mil/whs/directives/corres/pdf/605501p.pdf. (3) Any health care services...://www.dtic.mil/whs/directives/corres/pdf/302041p.pdf. (h) Emergency Health Care. The Secretaries of the...
32 CFR 239.15 - List of HAP field offices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Address: http://www.spk.usace.army.mil Alaska, Arizona, California, Nevada, Utah, Idaho, Oregon, Pacific....O. Box 889, Savannah, GA 31402-0889. 1-800-861-8144. Internet Address: http://www.sas.usace.army.mil..., TX 76102-0300. (817) 886-1112. 1-888-231-7751. Internet Address: http://www.swf.usace.army.mil...
Analysis of On-Board Oxygen and Nitrogen Generation Systems for Surface Vessels.
1983-06-01
and Pressure Vessel Code SAE AIR 822 Oxygen for General Aviation Aircraft SAE AIR 825 Oxygen for Aircrafts SAE AIR 1059 Transportation and Maintenance...OF THE TITLE MIL-T-27730 Threaded Components MIL-P-27401 A 40 Micron Filter For Nitrogen MIL-V-33650 Internal Straight Threads ASME Code VIII Boiler
Water Adsorption on Various Metal Organic Framework
NASA Astrophysics Data System (ADS)
Teo, H. W. B.; Chakraborty, A.
2017-12-01
In this paper, Metal Organic Framework (MOF) undergoes N2 and water adsorption experiment to observe how the material properties affects the water sorption performance. The achieved N2 isotherms is used to estimate the BET surface area, pore volume and, most importantly, the pore size distribution of the adsorbent material. It is noted that Aluminium Fumarate and CAU-10 has pore distribution of about 6Å while MIL-101(Cr) has 16 Å. The water adsorption isotherms at 25°C shows MIL-101(Cr) has a long hydrophobic length from relative pressure of 0 ≤ P/Ps ≤ 0.4 with a maximum water uptake of 1kg/kg sorbent. Alkali metal ions doped MIL-101(Cr) reduced the hydrophobic length and maximum water uptake of original MIL-101(Cr). Aluminium Fumarate and CAU-10 has lower water uptake, but the hydrophobic length of both materials is within relative pressure of P/Ps ≤ 0.2. The kinetic behaviour of doped MIL-101(Cr), Aluminium Fumarate and CAU-10 are faster than MIL-101(Cr).
Nanometric MIL-125-NH2 Metal–Organic Framework as a Potential Nerve Agent Antidote Carrier
Vilela, Sérgio M. F.; Salcedo-Abraira, Pablo; Colinet, Isabelle; Salles, Fabrice; Serre, Christian; Horcajada, Patricia
2017-01-01
The three-dimensional (3D) microporous titanium aminoterephthalate MIL-125-NH2 (MIL: Material of Institut Lavoisier) was successfully isolated as monodispersed nanoparticles, which are compatible with intravenous administration, by using a simple, safe and low-cost synthetic approach (100 °C/32 h under atmospheric pressure) so that for the first time it could be considered for encapsulation and the release of drugs. The nerve agent antidote 2-[(hydroxyimino)methyl]-1-methyl-pyridinium chloride (2-PAM or pralidoxime) was effectively encapsulated into the pores of MIL-125-NH2 as a result of the interactions between 2-PAM and the pore walls being mediated by π-stacking and hydrogen bonds, as deduced from infrared spectroscopy and Monte Carlo simulation studies. Finally, colloidal solutions of MIL-125-NH2 nanoparticles exhibited remarkable stability in different organic media, aqueous solutions at different pH and under relevant physiological conditions over time (24 h). 2-PAM was rapidly released from the pores of MIL-125-NH2 in vitro. PMID:29023426
Liger, D; vanderSpek, J C; Gaillard, C; Cansier, C; Murphy, J R; Leboulch, P; Gillet, D
1997-04-07
We have constructed two fusion proteins, DAB389-mIL-3 and DAB389-(Gly4Ser)2-mIL-3, in which the receptor-binding domain of diphtheria toxin is replaced by mouse interleukin-3 (IL-3). Cytotoxic activity of the fusion toxins was observed on three out of six cell lines assayed. This toxicity was mediated through binding to the IL-3 receptor as it was inhibited in a dose-dependent manner with murine IL-3 or anti-IL-3 neutralizing antibodies. DAB389-(Gly4Ser)2-mIL-3 was up to 5 times more toxic than DAB389-mIL-3, depending on the cell line (0.8 x 10(-10) M < IC50 < 3 x 10(-10) M). These proteins can be used for the detection of IL-3 receptors on mouse cells and should allow for the selective elimination of IL-3 receptor-positive pluripotent hematopoietic stem cells prior to bone marrow transplantation.
Dua, R; Nandlal, B
2004-03-01
The present study was conducted to compare and evaluate the tensile strength of silver soldered joints of stainless steel and cobalt-chromium orthodontic wires with band material. An attempt was made to observe the effect of joint site preparation by incorporation of tack welding and increasing metal to metal surface contact area by flattening an end of the wire prior to soldering along with the regularly used round wires without tack welding. A total of 180 wire specimens were soldered to 180 band specimens. Fifteen samples according to joint site preparation were included for each of the wire groups i.e. Gloria (S.S.), Remanium (S.S.) and Remaloy (Co-Cr) wires of 0.036" in diameter. The findings of the study were suggestive that all three wires may be used for preparing silver soldered joints irrespective of the quality of the wire. However, when subjecting the wire to joint site preparation, Gloria (S.S.) wire showed less tensile strength as compared to Remanium and Remaloy.
Zawawi, Khalid H; Malki, Ghadah A
2014-01-01
Objective: The aim of this study was to compare the amount of root resorption after orthodontic treatment between the bidimensional and the Roth straight-wire techniques. Another objective was to compare the amount of root resorption in the whole sample studied and record the prevalence of root resorption. Materials and Methods: The sample consisted of 40 patients (age ranged between 11 and 18 years) with Angle Class II division 1 malocclusions, treated nonextraction. Twenty patients were treated with bidimensional technique and 20 with a 0.018-inch Roth straight-wire technique. Root lengths of the maxillary incisors were measured on pre- and post-treatment periapical radiographs. Results: The results demonstrated that the bidimensional and Roth straight-wire groups showed significant root resorption after treatment, 1.11 (0.17) and 0.86 (0.05), respectively, P < 0.001. When comparing the amount of root shortening between the bidimensional and Roth straight-wire groups, there was no significant difference between the mean change from pre- to post-treatment between bidimensional group (mean = 1.00 ± 1.34) and Roth straight-wire group (mean = 0.88 ± 0.86), P = 0.63. Considering the whole sample, there was no root resoprtion in 32.5% of the analysed teeth. There was only mild resorption in 56.2%, moderate in 8.8% and severe in only 2.5% of the teeth. Conclusions: Treatment with the bidimensional technique did not produce an increase in the amount of root resorption. The prevalence and amount of root resorption was similar between bidimensional and Roth straight-wire techniques. PMID:25426453
Zawawi, Khalid H; Malki, Ghadah A
2014-10-01
The aim of this study was to compare the amount of root resorption after orthodontic treatment between the bidimensional and the Roth straight-wire techniques. Another objective was to compare the amount of root resorption in the whole sample studied and record the prevalence of root resorption. The sample consisted of 40 patients (age ranged between 11 and 18 years) with Angle Class II division 1 malocclusions, treated nonextraction. Twenty patients were treated with bidimensional technique and 20 with a 0.018-inch Roth straight-wire technique. Root lengths of the maxillary incisors were measured on pre- and post-treatment periapical radiographs. The results demonstrated that the bidimensional and Roth straight-wire groups showed significant root resorption after treatment, 1.11 (0.17) and 0.86 (0.05), respectively, P < 0.001. When comparing the amount of root shortening between the bidimensional and Roth straight-wire groups, there was no significant difference between the mean change from pre- to post-treatment between bidimensional group (mean = 1.00 ± 1.34) and Roth straight-wire group (mean = 0.88 ± 0.86), P = 0.63. Considering the whole sample, there was no root resoprtion in 32.5% of the analysed teeth. There was only mild resorption in 56.2%, moderate in 8.8% and severe in only 2.5% of the teeth. Treatment with the bidimensional technique did not produce an increase in the amount of root resorption. The prevalence and amount of root resorption was similar between bidimensional and Roth straight-wire techniques.
Correlating the EMC analysis and testing methods for space systems in MIL-STD-1541A
NASA Technical Reports Server (NTRS)
Perez, Reinaldo J.
1990-01-01
A study was conducted to improve the correlation between the electromagnetic compatibility (EMC) analysis models stated in MIL-STD-1541A and the suggested testing methods used for space systems. The test and analysis methods outlined in MIL-STD-1541A are described, and a comparative assessment of testing and analysis techniques as they relate to several EMC areas is presented. Suggestions on present analysis and test methods are introduced to harmonize and bring the analysis and testing tools in MIL-STD-1541A into closer agreement. It is suggested that test procedures in MIL-STD-1541A must be improved by providing alternatives to the present use of shielded enclosures as the primary site for such tests. In addition, the alternate use of anechoic chambers and open field test sites must be considered.
Low-Field and High-Field Characterization of THUNDER Actuators
NASA Technical Reports Server (NTRS)
Ounaies, Z.; Mossi, K.; Smith, R.; Bernd, J.; Bushnell, Dennis M. (Technical Monitor)
2001-01-01
THUNDER (THin UNimorph DrivER) actuators are pre-stressed piezoelectric devices developed at NASA Langley Research Center (LaRC) that exhibit enhanced strain capabilities. As a result, they are of interest in a variety of aerospace applications. Characterization of their performance as a function of electric field, temperature and frequency is needed in order to optimize their operation. Towards that end, a number of THUNDER devices were obtained from FACE International Co. with a stainless steel substrate varying in thickness from 1 mil to 20 mils. The various devices were evaluated to determine low-field and high-field displacement its well as the polarization hysteresis loops. The thermal stability of these drivers was evaluated by two different methods. First, the samples were thermally cycled under electric field by systematically increasing the maximum temperature from 25 C to 200 C while the displacement was being measured. Second, the samples were isothermally aged at 0 C, 50 C, 100 C. and 150 C in air, and the isothermal decay of the displacement was measured at room temperature as a function of time.
Building Safer Systems With SpecTRM
NASA Technical Reports Server (NTRS)
2003-01-01
System safety, an integral component in software development, often poses a challenge to engineers designing computer-based systems. While the relaxed constraints on software design allow for increased power and flexibility, this flexibility introduces more possibilities for error. As a result, system engineers must identify the design constraints necessary to maintain safety and ensure that the system and software design enforces them. Safeware Engineering Corporation, of Seattle, Washington, provides the information, tools, and techniques to accomplish this task with its Specification Tools and Requirements Methodology (SpecTRM). NASA assisted in developing this engineering toolset by awarding the company several Small Business Innovation Research (SBIR) contracts with Ames Research Center and Langley Research Center. The technology benefits NASA through its applications for Space Station rendezvous and docking. SpecTRM aids system and software engineers in developing specifications for large, complex safety critical systems. The product enables engineers to find errors early in development so that they can be fixed with the lowest cost and impact on the system design. SpecTRM traces both the requirements and design rationale (including safety constraints) throughout the system design and documentation, allowing engineers to build required system properties into the design from the beginning, rather than emphasizing assessment at the end of the development process when changes are limited and costly.System safety, an integral component in software development, often poses a challenge to engineers designing computer-based systems. While the relaxed constraints on software design allow for increased power and flexibility, this flexibility introduces more possibilities for error. As a result, system engineers must identify the design constraints necessary to maintain safety and ensure that the system and software design enforces them. Safeware Engineering Corporation, of Seattle, Washington, provides the information, tools, and techniques to accomplish this task with its Specification Tools and Requirements Methodology (SpecTRM). NASA assisted in developing this engineering toolset by awarding the company several Small Business Innovation Research (SBIR) contracts with Ames Research Center and Langley Research Center. The technology benefits NASA through its applications for Space Station rendezvous and docking. SpecTRM aids system and software engineers in developing specifications for large, complex safety critical systems. The product enables engineers to find errors early in development so that they can be fixed with the lowest cost and impact on the system design. SpecTRM traces both the requirements and design rationale (including safety constraints) throughout the system design and documentation, allowing engineers to build required system properties into the design from the beginning, rather than emphasizing assessment at the end of the development process when changes are limited and costly.
NASA Technical Reports Server (NTRS)
Baur, M. E.; Hayes, J. M.; Studley, S. A.; Walter, M. R.
1985-01-01
Several diamond drill cores from formations within the Hamersley Group of Western Australia have been studied for evidence of short-range variations in the isotopic compositions of the carbonates. For a set of 32 adjacent microbands analyzed in a specimen from the Marra Mamba Iron Formation, carbon isotope compositions of individual microbands ranged from -2.8 to -19.8 per mil compared to PDB and oxygen isotope compositions ranged from 10.2 to 20.8 per mil compared to SMOW. A pattern of alternating abundances was present, with the average isotopic contrasts between adjacent microbands being 3.0 per mil for carbon and 3.1 per mil for oxygen. Similar results were obtained for a suite of 34 microbands (in four groups) from the Bruno's Band unit of the Mount Sylvia Formation. Difficulties were experienced in preparing samples of single microbands from the Dales Gorge Member of the Brockman Iron Formation, but overall isotopic compositions were in good agreement with values reported by previous authors. Chemical analyses showed that isotopically light carbon and oxygen were correlated with increased concentrations of iron. The preservation of these millimeter-scale variations in isotopic abundances is interpreted as inconsistent with a metamorphic origin for the isotopically light carbon in the BIF carbonates. A biological origin is favored for the correlated variations in 13C and Fe, and it is suggested that the 13C-depleted carbonates may derive either from fermentative metabolism or from anaerobic respiration. A model is presented in which these processes occur near the sediment-water interface and are coupled with an initial oxidative precipitation of the iron.
Measuring meaning in life following cancer
Jim, Heather S.; Purnell, Jason Q.; Richardson, Susan A.; Golden-Kreutz, Deanna; Andersen, Barbara L.
2007-01-01
Meaning in life is a multi-faceted construct that has been conceptualized in diverse ways. It refers broadly to the value and purpose of life, important life goals, and for some, spirituality. We developed a measure of meaning in life derived from this conceptualization and designed to be a synthesis of relevant theoretical and empirical traditions. Two samples, all cancer patients, provided data for scale development and psychometric study. From exploratory and confirmatory factor analyses the Meaning in Life Scale (MiLS) emerged, and includes four aspects: Harmony and Peace, Life Perspective, Purpose and Goals, Confusion and Lessened Meaning, and Benefits of Spirituality. Supporting data for reliability (internal consistency, test–retest) and construct validity (convergent, discriminant, individual differences) are provided. The MiLS offers a theoretically based and psychometrically sound assessment of meaning in life suitable for use with cancer patients. PMID:16838197
Bending effects and temperature dependence of magnetic properties in a Fe-rich amorphous wire
NASA Astrophysics Data System (ADS)
Bordin, G.; Buttino, G.; Poppi, M.
2001-08-01
Amorphous wires with composition Fe 77.5Si 7.5B 15 exhibit a very peculiar magnetization process characterized by a single and quite large Barkhausen jump. This gives rise to a squared hysteresis loop at a critical magnetic field. The bistable behaviour, widely studied in wires with typical length of 10 cm and diameter of 125 μm, appears above a length of about 7 cm in straight wires and disappears for curvature radius within the range 2-12 cm in bent wires. In this work it is shown that bistability occurs in bent wires, whatever their curvature is, provided the wires are long enough. To this purpose spiral-shaped samples with several turns are considered. However, when the wire length is not a integer number of turns the magnetization reverses through many large Barkhausen jumps. In this condition, varying the measuring temperature can activate the energy barriers for the jumps.
Delamination of Pearlitic Steel Wires: The Defining Role of Prior-Drawing Microstructure
NASA Astrophysics Data System (ADS)
Durgaprasad, A.; Giri, S.; Lenka, S.; Sarkar, Sudip Kumar; Biswas, Aniruddha; Kundu, S.; Mishra, S.; Chandra, S.; Doherty, R. D.; Samajdar, I.
2018-06-01
This article reports the occasional (< 10 pct of the actual production) delamination of pearlitic wires subjected to a drawing strain of 2.5. The original wire rods which exhibited post-drawing delamination had noticeably lower axial alignment of the pearlite: 22 ± 5 pct vs 34 ± 4 pct in the nondelaminated wires. Although all wires had similar through-thickness texture and stress gradients, delaminated wires had stronger gradients in composition and higher hardness across the ferrite-cementite interface. Carbide dissolution and formation of supersaturated ferrite were clearly correlated with delamination, which could be effectively mitigated by controlled laboratory annealing at 673 K. Direct observations on samples subjected to simple shear revealed significant differences in shear localizations. These were controlled by pearlite morphology and interlamellar spacing. Prior-drawing microstructure of coarse misaligned pearlite thus emerged as a critical factor in the wire drawing-induced delamination of the pearlitic wires.
The Oxygen Isotopic Composition of MIL 090001: A CR2 Chondrite with Abundant Refractory Inclusions
NASA Technical Reports Server (NTRS)
Keller, Lindsay P.; McKeegan, K. D.; Sharp, Z. D.
2012-01-01
MIL 090001 is a large (>6 kg) carbonaceous chondrite that was classified as a member of the CV reduced subgroup (CVred) that was recovered during the 2009-2010 ANSMET field season [1]. Based on the abundance of refractory inclusions and the extent of aqueous alteration, Keller [2] suggested a CV2 classification. Here we report additional mineralogical and petrographic data for MIL 090001, its whole-rock oxygen isotopic composition and ion microprobe analyses of individual phases. The whole rock oxygen isotopic analyses show that MIL 090001 should be classified as a CR chondrite.
2016-03-01
Fabrication with 0.09-µm High-Electron-Mobility Transistors (HEMTs) Using 2-mil Gallium Nitride (GaN) on Silicon Carbide (SiC) by John E Penn...for Fabrication with 0.09-µm High-Electron-Mobility Transistors (HEMTs) using 2-mil Gallium Nitride (GaN) on Silicon Carbide by John E Penn...µm High-Electron-Mobility Transistors (HEMTs) using 2-mil Gallium Nitride (GaN) on Silicon Carbide 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buragohain, Amlan; Couck, Sarah; Van Der Voort, Pascal
Four existing and three new functionalized chromium terephthalates having MIL-101 topology and denoted as Cr-MIL-101-X (existing ones with X=–F, 1-F; –Cl, 2-Cl; –Br, 3-Br; –CH{sub 3}, 4-CH{sub 3}; new ones with X=–C{sub 6}H{sub 4}, 5-C{sub 6}H{sub 4}; –F{sub 2}, 6-F{sub 2}, –(CH{sub 3}){sub 2}, 7-(CH{sub 3}){sub 2}) were synthesized under hydrothermal conditions. All the materials except 5-C{sub 6}H{sub 4} could be prepared by a general synthetic route, in which the mixtures of CrO{sub 3}, H{sub 2}BDC-X (BDC=1,4-benzenedicarboxylate) linkers, conc. HCl and water with a molar ratio of 1:1:3.9:222.2 were reacted at 180 °C for 144 h. Compared to the 144more » h of synthesis time, three of the compounds, namely 1-Cl, 2-Br and 5-C{sub 6}H{sub 4}, could be prepared in much shorter reaction times (12–18 h at 180–210 °C). The materials possess high thermal stability up to 270–300 °C in an air atmosphere. The activated compounds exhibit significant porosity (S{sub BET} range: 1273–2135 m{sup 2} g{sup −1}). At 0 °C and 1 bar, the CO{sub 2} adsorption capacities of the compounds fall in the 1.7–2.9 mmol g{sup −1} range. Compounds 1-F and 6-F{sub 2} showed enhanced CO{sub 2} uptake values compared to parent Cr-MIL-101. The benzene adsorption capacities of the compounds lie in the range of 66.2–139.5 molecules per unit cell at 50 °C and p/p{sub 0}=0.35. The increased benzene uptake value of 1-F compared to un-functionalized Cr-MIL-101 and 4-CH{sub 3} suggests that the fluorination has induced more hydrophobicity in Cr-MIL-101 as compared to the methylation. - Graphical abstract: Benzene adsorption by seven functionalized Cr-MIL-101-X metal-organic framework (MOF) materials Display Omitted - Highlights: • Seven functionalized Cr-MIL-101-X materials were synthesized solvothermally. • All Cr-MIL-101-X materials exhibited high thermal stability up to 270–300 °C in air. • All Cr-MIL-101-X compounds displayed considerable porosity towards N{sub 2}, CO{sub 2} and benzene. • Mono- and di-fluorinated Cr-MIL-101 materials showed enhanced CO{sub 2} adsorption capacities. • Cr-MIL-101-F adsorbed more benzene than non- and methyl-functionalized Cr-MIL-101.« less
NASA Technical Reports Server (NTRS)
Mittlefehldt, David W.
2008-01-01
There are numerous types of differentiated meteorites, but most represent either the crusts or cores of their parent asteroids. Ureilites, olivine-pyroxene-graphite rocks, are exceptions; they are mantle restites [1]. Dunite is expected to be a common mantle lithology in differentiated asteroids. In particular, models of the eucrite parent asteroid contain large volumes of dunite mantle [2-4]. Yet dunites are very rare among meteorites, and none are known associated with the howardite, eucrite, diogenite (HED) suite. Spectroscopic measurements of 4 Vesta, the probable HED parent asteroid, show one region with an olivine signature [5] although the surface is dominated by basaltic and orthopyroxenitic material equated with eucrites and diogenites [6]. One might expect that a small number of dunitic or olivine-rich meteorites might be delivered along with the HED suite. The 46 gram meteoritic dunite MIL 03443 (Fig. 1) was recovered from the Miller Range ice field of Antarctica. This meteorite was tentatively classified as a mesosiderite because large, dunitic clasts are found in this type of meteorite, but it was noted that MIL 03443 could represent a dunite sample of the HED suite [7]. Here I will present a preliminary petrologic study of two thin sections of this meteorite.
ERIC Educational Resources Information Center
Nagle, John M.; Walker, Harold E.
The School Planning, Evaluation, and Communication System (SPECS) is an overall design for districtwide program assessment and development. It is both a way of interrelating planning and evaluation of individual programs and a way of comparing the outcomes of all district programs with the district's community-defined educational goals. This…
Vis- and NIR-based instruments for detection of black-tip damaged wheat kernels: A comparative study
USDA-ARS?s Scientific Manuscript database
Black-tip (BT) present in wheat kernels is a non-mycotoxic fungus that attacks the kernels wherein any of a number of molds forms a dark brown or black sooty mold at the tip of the wheat kernel. Three spectrometers covering the spectral ranges 950-1636nm (Spec1), 600-1045nm (Spec2), and 380-780nm (S...
Cast aluminium single crystals cross the threshold from bulk to size-dependent stochastic plasticity
NASA Astrophysics Data System (ADS)
Krebs, J.; Rao, S. I.; Verheyden, S.; Miko, C.; Goodall, R.; Curtin, W. A.; Mortensen, A.
2017-07-01
Metals are known to exhibit mechanical behaviour at the nanoscale different to bulk samples. This transition typically initiates at the micrometre scale, yet existing techniques to produce micrometre-sized samples often introduce artefacts that can influence deformation mechanisms. Here, we demonstrate the casting of micrometre-scale aluminium single-crystal wires by infiltration of a salt mould. Samples have millimetre lengths, smooth surfaces, a range of crystallographic orientations, and a diameter D as small as 6 μm. The wires deform in bursts, at a stress that increases with decreasing D. Bursts greater than 200 nm account for roughly 50% of wire deformation and have exponentially distributed intensities. Dislocation dynamics simulations show that single-arm sources that produce large displacement bursts halted by stochastic cross-slip and lock formation explain microcast wire behaviour. This microcasting technique may be extended to several other metals or alloys and offers the possibility of exploring mechanical behaviour spanning the micrometre scale.
NASA Astrophysics Data System (ADS)
Cataldo, Giuseppe; Moseley, S. H.; Hsieh, W.; Huang, W.; Stevenson, T.; Wollack, E.
2014-01-01
Many space-based observatories, such as Spitzer and Herschel, have opened the far-infrared (IR) window to the universe, revealing rich line and continuum spectra from objects ranging from interplanetary dust particles to galactic mergers and young galaxies in the early universe. Micro-Spec (µ-Spec) is proposed as a novel technology concept to enable new discoveries in the far-IR spectral range. µ-Spec will be a high-sensitivity, direct-detection spectrometer operating in the 450-1000 µm regime. It will have two antenna arrays, one for transmitting and one for receiving, and superconducting microstrip transmission lines for power division and phase delay. Using superconducting materials reduces losses at a minimum, thereby providing background-limited sensitivity (noise equivalent power, NEP, less than 3x10^-21 W/√Hz) at a resolution 1200, potentially making µ-Spec four orders of magnitude more sensitive than its most capable predecessors. Materials being investigated for the development of the instrument transmission line and detectors include niobium and niobium-titanium nitride for the former, and molybdenum nitride for the latter. In addition, the instrument will be integrated on a four-inch-diameter silicon chip. Such a dramatic size reduction is made possible by the fact that silicon has a refraction index three times that of vacuum, thereby allowing the transmission lines to be shorter than in vacuum by a factor of three. For all these reasons, µ-Spec can become an important capability under the low background conditions provided by space telescopes such as the space infrared telescope for cosmology and astrophysics SPICA, possible Explorers and cryogenically-cooled balloons. The discussion will illustrate a point design developed for initial demonstration with a 30% efficiency due to losses to other diffraction orders. Design variations on this implementation will be shown that lead to near-unity efficiency and will be the basis of future instruments. Models to analyze the properties of the superconductors will also be described along with transmission data used to test and validate the models.
Simultaneously efficient adsorption and photocatalytic degradation of tetracycline by Fe-based MOFs.
Wang, Dongbo; Jia, Feiyue; Wang, Hou; Chen, Fei; Fang, Ying; Dong, Wenbo; Zeng, Guangming; Li, Xiaoming; Yang, Qi; Yuan, Xingzhong
2018-06-01
Recently, Fe-based metal-organic frameworks (MOFs) have attracted increasing attention and been widely used. To date, however, it is unknown whether they can be employed to degrade tetracycline, one of the most widely used antibiotics. This work therefore aims to provide such support by comparing the performance of three Fe-based MOFs (namely, Fe-MIL-101, Fe-MIL-100, and Fe-MIL-53) in removing tetracycline. Experimental results showed that Fe-MIL-101 exhibited the best performance in tetracycline removal, with 96.6% of tetracycline being removed (initial tetracycline concentration at 50 mg/L) while Fe-MIL-100 and Fe-MIL-53 removed 57.4% and 40.6% under the same conditions. Additionally, the effects of adding dosage, adsorption time, and initial concentration of tetracycline on degradation efficiency were examined. It was found that the adsorption and photocatalytic degradation effect was better with the increase of time, the optimum dosage of Fe-MIL-101 was 0.5 g/L and the removal efficiency decreased with the increasing of initial tetracycline concentrations. Moreover, the trapping experiments and ESR tests indicated that O 2 -, OH and h + were the main active species in photocatalytic degradation process of tetracycline. Due to its high removal efficiency and simple synthesis, it could be used as a potential catalyst for degradation of tetracycline and other antibiotics. Copyright © 2018 Elsevier Inc. All rights reserved.
Interceptive Beam Diagnostics - Signal Creation and Materials Interactions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plum, Michael; Spallation Neutron Source, Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN
2004-11-10
The focus of this tutorial will be on interceptive beam diagnostics such as wire scanners, screens, and harps. We will start with an overview of the various ways beams interact with materials to create signals useful for beam diagnostics systems. We will then discuss the errors in a harp or wire scanner profile measurement caused by errors in wire position, number of samples, and signal errors. Finally we will apply our results to two design examples-the SNS wire scanner system and the SNS target harp.
MgB2 wire diameter reduction by hot isostatic pressing—a route for enhanced critical current density
NASA Astrophysics Data System (ADS)
Morawski, A.; Cetner, T.; Gajda, D.; Zaleski, A. J.; Häßler, W.; Nenkov, K.; Rindfleisch, M. A.; Tomsic, M.; Przysłupski, P.
2018-07-01
The effect of wire diameter reduction on the critical current density of pristine MgB2 wire was studied. Wires were treated by a hot isostatic pressing method at 570 °C and at pressures of up to 1.1 GPa. It was found that the wire diameter reduction induces an increase of up to 70% in the mass density of the superconducting cores. This feature leads to increases in critical current, critical current density, and pinning force density. The magnitude and field dependence of the critical current density are related to both grain connectivity and structural defects, which act as effective pinning centers. High field transport properties were obtained without doping of the MgB2 phase. A critical current density jc of 3500 A mm‑2 was reached at 4 K, 6 T for the best sample, which was a five-fold increase compared to MgB2 samples synthesized at ambient pressure.