Sample records for min analysis time

  1. Evaluation of the appropriate time period between sampling and analyzing for automated urinalysis

    PubMed Central

    Dolscheid-Pommerich, Ramona C.; Klarmann-Schulz, Ute; Conrad, Rupert; Stoffel-Wagner, Birgit; Zur, Berndt

    2016-01-01

    Introduction Preanalytical specifications for urinalysis must be strictly adhered to avoid false interpretations. Aim of the present study is to examine whether the preanalytical factor ‘time point of analysis’ significantly influences stability of urine samples for urine particle and dipstick analysis. Materials and methods In 321 pathological spontaneous urine samples, urine dipstick (Urisys™2400, Combur-10-Test™strips, Roche Diagnostics, Mannheim, Germany) and particle analysis (UF-1000 i™, Sysmex, Norderstedt, Germany) were performed within 90 min, 120 min and 240 min after urine collection. Results For urine particle analysis, a significant increase in conductivity (120 vs. 90 min: P < 0.001, 240 vs. 90 min: P < 0.001) and a significant decrease in WBC (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), RBC (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), casts (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001) and epithelial cells (120 vs. 90 min P = 0.610, 240 vs. 90 min P = 0.041) were found. There were no significant changes for bacteria. Regarding urine dipstick analysis, misclassification rates between measurements were significant for pH (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), leukocytes (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), nitrite (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), protein (120 vs. 90 min P < 0.001, 240 vs. 90 min P<0.001), ketone (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), blood (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), specific gravity (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001) and urobilinogen (120 vs. 90 min, P = 0.031). Misclassification rates were not significant for glucose and bilirubin. Conclusion Most parameters critically depend on the time window between sampling and analysis. Our study stresses the importance of adherence to early time points in urinalysis (within 90 min). PMID:26981022

  2. Non-linear Min protein interactions generate harmonics that signal mid-cell division in Escherichia coli

    PubMed Central

    Walsh, James C.; Angstmann, Christopher N.; Duggin, Iain G.

    2017-01-01

    The Min protein system creates a dynamic spatial pattern in Escherichia coli cells where the proteins MinD and MinE oscillate from pole to pole. MinD positions MinC, an inhibitor of FtsZ ring formation, contributing to the mid-cell localization of cell division. In this paper, Fourier analysis is used to decompose experimental and model MinD spatial distributions into time-dependent harmonic components. In both experiment and model, the second harmonic component is responsible for producing a mid-cell minimum in MinD concentration. The features of this harmonic are robust in both experiment and model. Fourier analysis reveals a close correspondence between the time-dependent behaviour of the harmonic components in the experimental data and model. Given this, each molecular species in the model was analysed individually. This analysis revealed that membrane-bound MinD dimer shows the mid-cell minimum with the highest contrast when averaged over time, carrying the strongest signal for positioning the cell division ring. This concurs with previous data showing that the MinD dimer binds to MinC inhibiting FtsZ ring formation. These results show that non-linear interactions of Min proteins are essential for producing the mid-cell positioning signal via the generation of second-order harmonic components in the time-dependent spatial protein distribution. PMID:29040283

  3. 18F-FET PET prior to recurrent high-grade glioma re-irradiation-additional prognostic value of dynamic time-to-peak analysis and early static summation images?

    PubMed

    Fleischmann, Daniel F; Unterrainer, Marcus; Bartenstein, Peter; Belka, Claus; Albert, Nathalie L; Niyazi, Maximilian

    2017-04-01

    Most high-grade gliomas (HGG) recur after initial multimodal therapy and re-irradiation (Re-RT) has been shown to be a valuable re-treatment option in selected patients. We evaluated the prognostic value of dynamic time-to-peak analysis and early static summation images in O-(2- 18 F-fluoroethyl)-l-tyrosine ( 18 F-FET) PET for patients treated with Re-RT ± concomitant bevacizumab. We retrospectively analyzed 72 patients suffering from recurrent HGG with 18 F-FET PET prior to Re-RT. PET analysis revealed the maximal tumor-to-background-ratio (TBR max ), the biological tumor volume, the number of PET-foci and pattern of time-activity-curves (TACs; increasing vs. decreasing). Furthermore, the novel PET parameters early TBR max (at 5-15 min post-injection) and minimal time-to-peak (TTP min ) were evaluated. Additional analysis was performed for gender, age, KPS, O6-methylguanine-DNA methyltransferase methylation status, isocitrate dehydrogenase 1 mutational status, WHO grade and concomitant bevacizumab therapy. The influence of PET and clinical parameters on post-recurrence survival (PRS) was investigated. Shorter TTP min was related to shorter PRS after Re-RT with 6 months for TTP min  < 12.5 min, 7 months for TTP min 12.5-25 min and 11 months for TTP min >25 min (p = 0.027). TTP min had a significant impact on PRS both on univariate (p = 0.027; continuous) and multivariate analysis (p = 0.011; continuous). Other factors significantly related to PRS on multivariate analysis were increasing vs. decreasing TACs (p = 0.008) and Karnofsky Performance Score (p = 0.015; <70 vs. ≥70). Early TBR max as well as the other conventional PET parameters were not significantly related to PRS on univariate analysis. Dynamic 18 F-FET PET with TTP min provides a high prognostic value for recurrent HGG prior to Re-RT, whereas early TBR max does not. Dynamic 18 F-FET PET using TTP min might help to personalize Re-RT treatment regimens in future through voxelwise TTP min analysis for dose painting purposes and PET-guided dose escalation.

  4. Comparison of salivary cortisol, heart rate, and oxygen saturation between early skin-to-skin contact with different initiation and duration times in healthy, full-term infants.

    PubMed

    Takahashi, Yuki; Tamakoshi, Koji; Matsushima, Miyoko; Kawabe, Tsutomu

    2011-03-01

    There are few studies that compare the physiological and biological efficacies between different early skin-to-skin contacts (SSC) post birth. To investigate physiologically and biochemically how early SSC with different initiation and duration time influence the stress post birth for full-term infants. Non-experimental study. Study I; Thirty-two infants who began SSC 5 min or less [birth SSC, mean initiation time (standard deviation): 1.6 (1.1) min] after birth and 36 infants who did so more than 5 min [very early SSC, 26.3 (5.0) min] in heart rate (HR) and oxygen saturation (SpO(2)) analysis. Study II; Eighteen infants who underwent SSC for 60 min or less [mean initiation time: 7.5 (12.2) min] and 61 infants who did so for more than 60 min [15.3 (12.5) min] in salivary cortisol analysis. HR and SpO(2) measured for 30 min post birth. Salivary cortisol concentration measured at 1 min, 60 min, and 120 min post birth. Birth SSC group reached HR stability of 120-160 bpm significantly faster than very early SSC group by Kaplan-Meier analysis (P=0.001 by log-rank test). As for SpO(2) stability of 92% and 96%, no significantly between-group difference was found. Salivary cortisol levels were significantly lower between 60 and 120 min after birth in SSC group, continuing for more than 60 min compared with SSC group for 60 min or less after adjustment for salivary cortisol level at 1 min besides the infant stress factors (P=0.046). Earlier SSC beginning within 5 min post birth and longer SSC continuing for more than 60 min within 120 min post birth are beneficial for stability of cardiopulmonary dynamics and the reduction of infant stress during the early period post birth. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  5. Short-term vs. long-term heart rate variability in ischemic cardiomyopathy risk stratification.

    PubMed

    Voss, Andreas; Schroeder, Rico; Vallverdú, Montserrat; Schulz, Steffen; Cygankiewicz, Iwona; Vázquez, Rafael; Bayés de Luna, Antoni; Caminal, Pere

    2013-01-01

    In industrialized countries with aging populations, heart failure affects 0.3-2% of the general population. The investigation of 24 h-ECG recordings revealed the potential of nonlinear indices of heart rate variability (HRV) for enhanced risk stratification in patients with ischemic heart failure (IHF). However, long-term analyses are time-consuming, expensive, and delay the initial diagnosis. The objective of this study was to investigate whether 30 min short-term HRV analysis is sufficient for comparable risk stratification in IHF in comparison to 24 h-HRV analysis. From 256 IHF patients [221 at low risk (IHFLR) and 35 at high risk (IHFHR)] (a) 24 h beat-to-beat time series (b) the first 30 min segment (c) the 30 min most stationary day segment and (d) the 30 min most stationary night segment were investigated. We calculated linear (time and frequency domain) and nonlinear HRV analysis indices. Optimal parameter sets for risk stratification in IHF were determined for 24 h and for each 30 min segment by applying discriminant analysis on significant clinical and non-clinical indices. Long- and short-term HRV indices from frequency domain and particularly from nonlinear dynamics revealed high univariate significances (p < 0.01) discriminating between IHFLR and IHFHR. For multivariate risk stratification, optimal mixed parameter sets consisting of 5 indices (clinical and nonlinear) achieved 80.4% AUC (area under the curve of receiver operating characteristics) from 24 h HRV analysis, 84.3% AUC from first 30 min, 82.2 % AUC from daytime 30 min and 81.7% AUC from nighttime 30 min. The optimal parameter set obtained from the first 30 min showed nearly the same classification power when compared to the optimal 24 h-parameter set. As results from stationary daytime and nighttime, 30 min segments indicate that short-term analyses of 30 min may provide at least a comparable risk stratification power in IHF in comparison to a 24 h analysis period.

  6. Increasing operating room efficiency through electronic medical record analysis.

    PubMed

    Attaallah, A F; Elzamzamy, O M; Phelps, A L; Ranganthan, P; Vallejo, M C

    2016-05-01

    We used electronic medical record (EMR) analysis to determine errors in operating room (OR) time utilisation. Over a two year period EMR data of 44,503 surgical procedures was analysed for OR duration, on-time, first case, and add-on time performance, within 19 surgical specialties. Maximal OR time utilisation at our institution could have saved over 302,620 min or 5,044 hours of OR efficiency over a two year period. Most specialties (78.95%) had inaccurately scheduled procedure times and therefore used the OR more than their scheduled allotment time. Significant differences occurred between the mean scheduled surgical durations (101.38 ± 87.11 min) and actual durations (108.18 ± 102.27 min; P < 0.001). Significant differences also occurred between the mean scheduled add-on durations (111.4 ± 75.5 min) and the actual add-on scheduled durations (118.6 ± 90.1 minutes; P < 0.001). EMR quality improvement analysis can be used to determine scheduling error and bias, in order to improve efficiency and increase OR time utilisation.

  7. Live-cell confocal microscopy and quantitative 4D image analysis of anchor cell invasion through the basement membrane in C. elegans

    PubMed Central

    Kelley, Laura C.; Wang, Zheng; Hagedorn, Elliott J.; Wang, Lin; Shen, Wanqing; Lei, Shijun; Johnson, Sam A.; Sherwood, David R.

    2018-01-01

    Cell invasion through basement membrane (BM) barriers is crucial during development, leukocyte trafficking, and for the spread of cancer. Despite its importance in normal and diseased states, the mechanisms that direct invasion are poorly understood, in large part because of the inability to visualize dynamic cell-basement membrane interactions in vivo. This protocol describes multi-channel time-lapse confocal imaging of anchor cell invasion in live C. elegans. Methods presented include outline slide preparation and worm growth synchronization (15 min), mounting (20 min), image acquisition (20-180 min), image processing (20 min), and quantitative analysis (variable timing). Images acquired enable direct measurement of invasive dynamics including invadopodia formation, cell membrane protrusions, and BM removal. This protocol can be combined with genetic analysis, molecular activity probes, and optogenetic approaches to uncover molecular mechanisms underlying cell invasion. These methods can also be readily adapted for real-time analysis of cell migration, basement membrane turnover, and cell membrane dynamics by any worm laboratory. PMID:28880279

  8. Ultratrace analysis of nine macrolides, including tulathromycin A (Draxxin), in edible animal tissues with minicolumn liquid chromatography tandem mass spectrometry.

    PubMed

    Martos, Perry A; Lehotay, Steven J; Shurmer, Bryn

    2008-10-08

    The analysis of nine macrolides is presented, including tulathromycin A (Draxxin), in beef, poultry, and pork muscle with a simple multiresidue extraction and analysis method using high-performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry. The sample preparation method involves extraction with acetonitrile and defatting with hexane followed by dilution of the extracts for analysis. Separation of the nine macrolides was performed using an Atlantis dC 18, 3 mum, 3.9 mm x 20 mm minicolumn (guard column). Detection was carried out with two multiple reaction monitoring experiments per macrolide. The method detection limits (MDLs) were based on three times standard deviation of eight repeat spikes at 3.0 ng/g of a mix of the nine macrolides in the various tissues. The MDLs and retention times for the macrolides were as follows: lincomycin, 0.19 ng/g (t R = 5.00 min); tulathromycin, 0.46 ng/g (t R = 5.63 min); spiramycin, 0.21 ng/g (t R = 6.06 min); pirlimycin, 0.10 ng/g (t R = 6.04 min); clindamycin, 0.16 ng/g (t R = 6.20 min); tilmicosin, 0.29 ng/g (t R = 6.38 min); erythromycin, 0.19 ng/g (t R = 6.62 min); tylosin, 0.10 ng/g (t R = 6.72 min); and josamycin, 0.09 ng/g (t R = 6.98 min). Precision at 25 ng/g (n = 4) ranged from 2.3 to 9.4% for the compounds from beef muscle. Of interest is the detection of incurred residues of tulathromycin A in edible calf tissue at 0.10-7 mug/g, which is presented here for the first time.

  9. Cost minimisation analysis: kilovoltage imaging with automated repositioning versus electronic portal imaging in image-guided radiotherapy for prostate cancer.

    PubMed

    Gill, S; Younie, S; Rolfo, A; Thomas, J; Siva, S; Fox, C; Kron, T; Phillips, D; Tai, K H; Foroudi, F

    2012-10-01

    To compare the treatment time and cost of prostate cancer fiducial marker image-guided radiotherapy (IGRT) using orthogonal kilovoltage imaging (KVI) and automated couch shifts and orthogonal electronic portal imaging (EPI) and manual couch shifts. IGRT treatment delivery times were recorded automatically on either unit. Costing was calculated from real costs derived from the implementation of a new radiotherapy centre. To derive cost per minute for EPI and KVI units the total annual setting up and running costs were divided by the total annual working time. The cost per IGRT fraction was calculated by multiplying the cost per minute by the duration of treatment. A sensitivity analysis was conducted to test the robustness of our analysis. Treatment times without couch shift were compared. Time data were analysed for 8648 fractions, 6057 from KVI treatment and 2591 from EPI treatment from a total of 294 patients. The median time for KVI treatment was 6.0 min (interquartile range 5.1-7.4 min) and for EPI treatment it was 10.0 min (interquartile range 8.3-11.8 min) (P value < 0.0001). The cost per fraction for KVI was A$258.79 and for EPI was A$345.50. The cost saving per fraction for KVI varied between A$66.09 and A$101.64 by sensitivity analysis. In patients where no couch shift was made, the median treatment delivery time for EPI was 8.8 min and for KVI was 5.1 min. Treatment time is less on KVI units compared with EPI units. This is probably due to automation of couch shift and faster evaluation of imaging on KVI units. Annual running costs greatly outweigh initial setting up costs and therefore the cost per fraction was less with KVI, despite higher initial costs. The selection of appropriate IGRT equipment can make IGRT practical within radiotherapy departments. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  10. Extending surgeon response times in tier 2 traumas does not adversely affect patient outcomes.

    PubMed

    Zimmerman, Steven Anthony; Reed, Christopher S; Reed, Alexander N; Jones, Ronald J; Chard, Annette; Reed, Donald N

    2018-06-01

    The presence of a trauma surgeon during patient resuscitations is required at most American College of Surgeons-verified trauma centers despite little evidence showing improved patient outcomes in the less-than-critically injured (Tier 2) trauma patients. This study was designed to identify the impact of extending required surgeon response times on outcomes in tier 2 trauma patients. An American College of Surgeons-verified level 2 trauma center extended the maximum allowed surgeon response time for tier 2 activations from 60 min to 120 min on November 1, 2011. Surgeon response time and patient outcomes of the retrospective control group (January 1, 2008-October 31, 2011) were then compared with the prospective test group (November 1, 2011-December 31, 2014). Primary outcomes included mortality and hospital length of stay (HLOS). Secondary outcomes were emergency department length of stay, and time from ED arrival to CT scan. A subset analysis of all patients evaluated by a surgeon within 60 min of arrival versus those evaluated by a surgeon after 60 min was also performed. The control and test groups were composed of 757 and 792 patients, and their mean injury severity score was 9.0 and 6.0, respectively. Emergency department length of stay showed a statistically significant increase of 12 min, whereas HLOS was unchanged throughout the study. Mortality was not significantly different between the groups. Subset analysis revealed a median surgeon arrival time of 15 min in the <60-min group and 85 min in the >60-min group, whereas the injury severity score, HLOS, and mortality were not significantly different between these subsets. No correlation existed between these outcomes and surgeon arrival time. Doubling required surgeon response time in tier 2 trauma patients does not produce negative outcomes in this patient group. Mandatory surgeon response times in similar patient groups can be re-evaluated to allow for greater flexibility of a limited surgeon workforce while still providing safe care. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Sugammadex efficacy for reversal of rocuronium- and vecuronium-induced neuromuscular blockade: A pooled analysis of 26 studies.

    PubMed

    Herring, William Joseph; Woo, Tiffany; Assaid, Christopher A; Lupinacci, Robert J; Lemmens, Hendrikus J; Blobner, Manfred; Khuenl-Brady, Karin S

    2017-09-01

    To summarize and compare efficacy of sugammadex with neostigmine or placebo for reversal of rocuronium- or vecuronium-induced neuromuscular blockade (NMB), and to demonstrate consistency of sugammadex results across various patient populations. Pooled analysis on data from 26 multicenter, randomized, Phase II and III studies. Operating room. 1855 adults undergoing surgery under general anesthesia and receiving rocuronium or vecuronium for NMB. Sugammadex (2.0mg/kg at second twitch reappearance [T 2 ; moderate NMB], 4.0mg/kg at 1-2 post-tetanic counts [PTC; deep NMB] or 16.0mg/kg at 3min after rocuronium 1.2mg/kg), neostigmine or placebo. Time to recovery of the train-of-four (TOF) ratio to 0.9. Geometric mean (95% CI) times to recovery to TOF ratio of 0.9 were 1.9 (1.8-2.0) min following sugammadex 2.0mg/kg and 10.6 (9.8-11.6) min following neostigmine administration at T 2 after rocuronium, and 2.9 (2.5-3.4) min and 17.4 (13.4-22.6) min, respectively, after vecuronium. Recovery times were 2.2 (2.1-2.3) min following sugammadex 4.0mg/kg and 19.0 (14.8-24.6) min following neostigmine administered at a target of 1-2 PTC after rocuronium, and 3.8 (3.0-5.0) min and 67.6 (56.3-81.2) min after vecuronium. Sugammadex administered 3min after rocuronium 1.2mg/kg resulted in rapid recovery (1.7 [1.5-2.0] min). Modest increases in mean recovery time were associated with vecuronium use (+1.6min [78%; (61%-98%)] versus rocuronium), mild-to-moderate renal impairment (+0.4min [20%; (9%-32%)] versus normal renal function) and geographic location (+1.0min [38%; (25%-52%)] in subjects in USA/Canada versus Europe/Japan). Sugammadex administered at recommended doses provides rapid and predictable reversal of rocuronium and vecuronium-induced moderate and deep NMB, and effective reversal 3min after rocuronium 1.2mg/kg. Robust recovery was seen across various patient factors, providing further confirmation of labeled dose recommendations. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Comparison of a fluorometric assay kit with high-performance liquid chromatography for the assessment of serum retinol concentration.

    PubMed

    Elom, Aglago Kouassivi; Imane, El Menchawy; Kaoutar, Benjeddou; Khalid, El Kari; Asmaa, El Hamdouchi; Mehdi, Azlaf; Noureddine, El Haloui; Hassan, Aguenaou

    2015-06-01

    Although high-performance liquid chromatography (HPLC) is the commonly used method for the analysis of retinol in biological samples, simple and rapid test kits are available. This study compared a rapid test kit (ICHECK Fluoro®) to HPLC for the assessment of serum retinol concentrations. For the analysis by HPLC, sample preparation included standard deproteinization and extraction phases. The analysis by ICHECK was performed by injecting serum into IEX reagent vials (n=89) and mixing manually for separation. After precipitation of the proteins, the vial was introduced into the chamber of the ICHECK Fluoro and analysed at 0 min (ICHECK0min) and 15 min later (ICHECK15min). Bland and Altman approach was applied to test the agreement between HPLC and ICHECK. Mean HPLC, ICHECK0min and ICHECK15min values were 421.2±106.0 µg/L, 423.1±118.3 µg/L and 413.2±107.6 µg/L, respectively. Retinol concentrations significantly decreased in the IEX solution over time (p<0.001). No significant proportional bias was observed between HPLC and ICHECK0min (r-0.038, p=0.73) and ICHECK15min (r=-0.024, p=0.82). Fixed biases (HPLC minus ICHECK) for ICHECK0min and ICHECK15min were respectively -1.9±23.1 µg/l (p=0.45) and 8.0±22.7 µg/l (p=0.002). ICHECK Fluoro may offer a reliable mean for assessing serum retinol for measurements performed with no significant time delay.

  13. Wear behavior of AA 5083/SiC nano-particle metal matrix composite: Statistical analysis

    NASA Astrophysics Data System (ADS)

    Hussain Idrisi, Amir; Ismail Mourad, Abdel-Hamid; Thekkuden, Dinu Thomas; Christy, John Victor

    2018-03-01

    This paper reports study on statistical analysis of the wear characteristics of AA5083/SiC nanocomposite. The aluminum matrix composites with different wt % (0%, 1% and 2%) of SiC nanoparticles were fabricated by using stir casting route. The developed composites were used in the manufacturing of spur gears on which the study was conducted. A specially designed test rig was used in testing the wear performance of the gears. The wear was investigated under different conditions of applied load (10N, 20N, and 30N) and operation time (30 mins, 60 mins, 90 mins, and 120mins). The analysis carried out at room temperature under constant speed of 1450 rpm. The wear parameters were optimized by using Taguchi’s method. During this statistical approach, L27 Orthogonal array was selected for the analysis of output. Furthermore, analysis of variance (ANOVA) was used to investigate the influence of applied load, operation time and SiC wt. % on wear behaviour. The wear resistance was analyzed by selecting “smaller is better” characteristics as the objective of the model. From this research, it is observed that experiment time and SiC wt % have the most significant effect on the wear performance followed by the applied load.

  14. When continuous observations just won't do: developing accurate and efficient sampling strategies for the laying hen.

    PubMed

    Daigle, Courtney L; Siegford, Janice M

    2014-03-01

    Continuous observation is the most accurate way to determine animals' actual time budget and can provide a 'gold standard' representation of resource use, behavior frequency, and duration. Continuous observation is useful for capturing behaviors that are of short duration or occur infrequently. However, collecting continuous data is labor intensive and time consuming, making multiple individual or long-term data collection difficult. Six non-cage laying hens were video recorded for 15 h and behavioral data collected every 2 s were compared with data collected using scan sampling intervals of 5, 10, 15, 30, and 60 min and subsamples of 2 second observations performed for 10 min every 30 min, 15 min every 1 h, 30 min every 1.5 h, and 15 min every 2 h. Three statistical approaches were used to provide a comprehensive analysis to examine the quality of the data obtained via different sampling methods. General linear mixed models identified how the time budget from the sampling techniques differed from continuous observation. Correlation analysis identified how strongly results from the sampling techniques were associated with those from continuous observation. Regression analysis identified how well the results from the sampling techniques were associated with those from continuous observation, changes in magnitude, and whether a sampling technique had bias. Static behaviors were well represented with scan and time sampling techniques, while dynamic behaviors were best represented with time sampling techniques. Methods for identifying an appropriate sampling strategy based upon the type of behavior of interest are outlined and results for non-caged laying hens are presented. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Effect of tracheostomy tube on work of breathing: Comparison of pre- and post-decannulation.

    PubMed

    Villalba, Darío; Feld, Viviana; Leiva, Valeria; Scrigna, Mariana; Distéfano, Eduardo; Pratto, Romina; Rodriguez, Matías; Collins, Jesica; Rocco, Ana; Matesa, Amelia; Rossi, Damián; Areas, Laura; Virgilio, Sacha; Golfarini, Nicolás; Gil-Rosetti, Gregorio; Diaz-Ballve, Pablo; Planells, Fernando

    2016-01-01

    To describe and compare the work of breathing (WOB) during spontaneous breathing under four conditions: (1) breathing through a tracheostomy tube with an inflated cuff, (2) breathing through the upper airway (UA) with a deflated cuff and occluded tube, (3) breathing through the UA with an occluded cuffless tube, and (4) postdecannulation. Patients who tolerated an occluded cuffless tube were included. Ventilatory variables and esophageal pressure were recorded. The pressure-time product (PTP), PTP/min, and PTP/min/tidal volume (PTP/min/VT) were measured. Each condition was measured for 5 min with a 15 min time interval between evaluations. Quantitative data are expressed as mean ± standard deviation. Single-factor analysis of variance was used, and the Games-Howell test was used for post hoc analysis of comparisons between group means ( P ≤ 0.05). Eight patients were studied under each of the four conditions described above. Statistically significant differences were found for PTP, PTP/min, and PTP/min/VT. In the post hoc analysis for PTP, significant differences among all conditions were found. For PTP/min, there was no significant difference between Conditions 2 and 4 ( P = 0.138), and for PTP/min/VT, there was no significant difference between Conditions 1 and 2 ( P = 0.072) or between Conditions 2 and 3 ( P = 0.106). A trend toward a higher PTP, PTP/min, and PTP/min/VT was observed when breathing through a cuffless tracheostomy tube. The four conditions differed with respect to WOB. Cuff inflation could result in a reduced WOB because there is less dead space. Cuffless tracheostomy tubes generate increased WOB, perhaps due to the material deformity caused by body temperature.

  16. 18F-DCFPyL PET/CT in the Detection of Prostate Cancer at 60 and 120 Minutes: Detection Rate, Image Quality, Activity Kinetics, and Biodistribution.

    PubMed

    Wondergem, Maurits; van der Zant, Friso M; Knol, Remco J J; Lazarenko, Sergiy V; Pruim, Jan; de Jong, Igle J

    2017-11-01

    There is increasing interest in PET/CT with prostate-specific membrane antigen (PSMA) tracers for imaging of prostate cancer because of the higher detection rates of prostate cancer lesions than with PET/CT with choline. For 68 Ga-PSMA-11 tracers, late imaging at 180 min after injection instead of imaging at 45-60 min after injection improves the detection of prostate cancer lesions. For 18 F-DCFPyL, improved detection rates have recently been reported in a small pilot study. In this study, we report the effects of PET/CT imaging at 120 min after injection of 18 F-DCFPyL in comparison to images acquired at 60 min after injection in a larger clinical cohort of 66 consecutive patients with histopathologically proven prostate cancer. Methods: Images were acquired 60 and 120 min after injection of 18 F-DCFPyL. We report the positive lesions specified for anatomic locations (prostate, seminal vesicles, local lymph nodes, distant lymph nodes, bone, and others) at both time points by visual analysis, the image quality at both time points, and a semiquantitative analysis of the tracer activity in both prostate cancer lesions as well as normal tissues at both time points. Results: Our data showed a significantly increasing uptake of 18 F-DCFPyL between 60 and 120 min after injection in 203 lesions characteristic for prostate cancer (median, 10.78 vs. 12.86, P < 0.001, Wilcoxon signed-rank test). By visual analysis, 38.5% of all patients showed more lesions using images at 120 min after injection than using images at 60 min after injection, and in 9.2% a change in TNM staging was found. All lesions seen on images 60 min after injection were also visible on images 120 min after injection. A significantly better mean signal-to-noise ratio of 11.93 was found for images acquired 120 min after injection ( P < 0.001, paired t test; signal-to-noise ratio at 60 min after injection, 11.15). Conclusion: 18 F-DCFPyL PET/CT images at 120 min after injection yield a higher detection rate of prostate cancer characteristic lesions than images at 60 min after injection. Further studies are needed to elucidate the best imaging time point for 18 F-DCFPyL. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  17. Evaluation of time, attendance of medical staff, and resources during interstitial brachytherapy for prostate cancer : DEGRO-QUIRO trial.

    PubMed

    Tselis, N; Maurer, U; Popp, W; Sack, H; Zamboglou, N

    2014-04-01

    The German Society of Radiation Oncology initiated a multicenter trial to evaluate core processes and subprocesses of radiotherapy by prospective evaluation of all important procedures in the most frequent malignancies treated by radiation therapy. The aim of this analysis was to assess the required resources for interstitial high-dose-rate (HDR) and low-dose-rate (LDR) prostate brachytherapy (BRT) based on actual time measurements regarding allocation of personnel and room occupation needed for specific procedures. Two radiotherapy centers (community hospital of Offenbach am Main and community hospital of Eschweiler) participated in this prospective study. Working time of the different occupational groups and room occupancies for the workflow of prostate BRT were recorded and methodically assessed during a 3-month period. For HDR and LDR BRT, a total of 560 and 92 measurements, respectively, were documented. The time needed for treatment preplanning was median 24 min for HDR (n = 112 measurements) and 6 min for LDR BRT (n = 21). Catheter implantation with intraoperative HDR real-time planning (n = 112), postimplantation HDR treatment planning (n = 112), and remotely controlled HDR afterloading irradiation (n = 112) required median 25, 39, and 50 min, respectively. For LDR real-time planning (n = 39) and LDR treatment postplanning (n = 32), the assessed median duration was 91 and 11 min, respectively. Room occupancy and overall mean medical staff times were 194 and 910 min respectively, for HDR, and 113 and 371 min, respectively, for LDR BRT. In this prospective analysis, the resource requirements for the application of HDR and LDR BRT of prostate cancer were assessed methodically and are presented for first time.

  18. Effect of delayed polymerization time and bracket manipulation on orthodontic bracket bonding

    NASA Astrophysics Data System (ADS)

    Ponikvar, Michael J.

    This study examined the effect of bracket manipulation in combination with delayed polymerization times on orthodontic bracket shear bond strength and degree of resin composite conversion. Orthodontics brackets were bonded to extracted third molars in a simulated oral environment after a set period of delayed polymerization time and bracket manipulation. After curing the bracket adhesive, each bracket underwent shear bond strength testing followed by micro-Raman spectroscopy analysis to measure the degree of conversion of the resin composite. Results demonstrated the shear bond strength and the degree of conversion of ceramic brackets did not vary over time. However, with stainless steel brackets there was a significant effect (p ≤ 0.05) of delay time on shear bond strength between the 0.5 min and 10 min bracket groups. In addition, stainless steel brackets showed significant differences related to degree of conversion over time between the 0.5 min and 5 min groups, in addition to the 0.5 min and 10 min groups. This investigation suggests that delaying bracket adhesive polymerization up to a period of 10 min then adjusting the orthodontic bracket may increase both shear bond strength and degree of conversion of stainless steel brackets while having no effect on ceramic brackets.

  19. Evaluation of Salmonella movement through the gut of the lesser mealworm, Alphitobius diaperinus (Coleoptera: Tenebrionidae).

    PubMed

    Zheng, Longyu; Crippen, Tawni L; Sheffield, Cynthia L; Poole, Toni L; Yu, Ziniu; Tomberlin, Jeffrey K

    2012-04-01

    The lesser mealworm, Alphitobius diaperinus is an important poultry pest prevalent during production that is capable of vectoring pathogens. This study was undertaken to determine the gut transit time of Salmonella for biosecurity risk analysis of pathogen dispersal into the environment. Adult and larval A. diaperinus were exposed to two concentrations of a fluorescently labeled Salmonella enterica for 15, 30, and 60 min time periods then externally disinfected to evaluate internal transfer of Salmonella. The insects were monitored every 30 min over 4 h and evacuated frass (feces) processed for the marker Salmonella. The minimum time monitored was 45 min (15 exposure+30 min time point), and the maximum was 5 h (60 exposure+4 h time point). Adults treated with 10(6) or 10(8) colony-forming units (cfu)/mL, which produced Salmonella positive frass within the 5 h experimental time, displayed a mean gut transit time of 144.4 min (range 90-270 min) and 186.3 min (range 120-300 min), respectively. Larvae treated with 10(6) or 10(8) cfu/mL displayed a mean gut transit time of 172.5 min (range 120-300 min) and 131.7 min (range 60-300 min), respectively. Understanding the sources and contribution of reservoir populations of pathogens in poultry production operations is important for development of biosecurity measures to mitigate their transfer. A. diaperinus are prevalent in production operations and difficult to suppress. Management standards accept the reutilization of litter in which insects survive between flock rotations. Removing litter and spreading it onto nearby fields results in the inadvertent dispersal of beetles. Few studies demonstrating the specific bacterial dispersal capacities of these insects have been performed. This study determined that Salmonella acquired internally, commonly transits the gut, allowed the insect to disperse viable pathogenic bacteria within 2-3 h.

  20. Optimizing value utilizing Toyota Kata methodology in a multidisciplinary clinic.

    PubMed

    Merguerian, Paul A; Grady, Richard; Waldhausen, John; Libby, Arlene; Murphy, Whitney; Melzer, Lilah; Avansino, Jeffrey

    2015-08-01

    Value in healthcare is measured in terms of patient outcomes achieved per dollar expended. Outcomes and cost must be measured at the patient level to optimize value. Multidisciplinary clinics have been shown to be effective in providing coordinated and comprehensive care with improved outcomes, yet tend to have higher cost than typical clinics. We sought to lower individual patient cost and optimize value in a pediatric multidisciplinary reconstructive pelvic medicine (RPM) clinic. The RPM clinic is a multidisciplinary clinic that takes care of patients with anomalies of the pelvic organs. The specialties involved include Urology, General Surgery, Gynecology, and Gastroenterology/Motility. From May 2012 to November 2014 we performed time-driven activity-based costing (TDABC) analysis by measuring provider time for each step in the patient flow. Using observed time and the estimated hourly cost of each of the providers we calculated the final cost at the individual patient level, targeting clinic preparation. We utilized Toyota Kata methodology to enhance operational efficiency in an effort to optimize value. Variables measured included cost, time to perform a task, number of patients seen in clinic, percent value-added time (VAT) to patients (face to face time) and family experience scores (FES). At the beginning of the study period, clinic costs were $619 per patient. We reduced conference time from 6 min/patient to 1 min per patient, physician preparation time from 8 min to 6 min and increased Medical Assistant (MA) preparation time from 9.5 min to 20 min, achieving a cost reduction of 41% to $366 per patient. Continued improvements further reduced the MA preparation time to 14 min and the MD preparation time to 5 min with a further cost reduction to $194 (69%) (Figure). During this study period, we increased the number of appointments per clinic. We demonstrated sustained improvement in FES with regards to the families overall experience with their providers. Value added time was increased from 60% to 78% but this was not significant. Time-based cost analysis effectively measures individualized patient cost. We achieved a 69% reduction in clinic preparation costs. Despite this reduction in costs, we were able to maintain VAT and sustain improvements in family experience. In caring for complex patients, lean management methodology enables optimization of value in a multidisciplinary clinic. Copyright © 2015. Published by Elsevier Ltd.

  1. Criterion-Related Validity of the Distance- and Time-Based Walk/Run Field Tests for Estimating Cardiorespiratory Fitness: A Systematic Review and Meta-Analysis.

    PubMed

    Mayorga-Vega, Daniel; Bocanegra-Parrilla, Raúl; Ornelas, Martha; Viciana, Jesús

    2016-01-01

    The main purpose of the present meta-analysis was to examine the criterion-related validity of the distance- and time-based walk/run tests for estimating cardiorespiratory fitness among apparently healthy children and adults. Relevant studies were searched from seven electronic bibliographic databases up to August 2015 and through other sources. The Hunter-Schmidt's psychometric meta-analysis approach was conducted to estimate the population criterion-related validity of the following walk/run tests: 5,000 m, 3 miles, 2 miles, 3,000 m, 1.5 miles, 1 mile, 1,000 m, ½ mile, 600 m, 600 yd, ¼ mile, 15 min, 12 min, 9 min, and 6 min. From the 123 included studies, a total of 200 correlation values were analyzed. The overall results showed that the criterion-related validity of the walk/run tests for estimating maximum oxygen uptake ranged from low to moderate (rp = 0.42-0.79), with the 1.5 mile (rp = 0.79, 0.73-0.85) and 12 min walk/run tests (rp = 0.78, 0.72-0.83) having the higher criterion-related validity for distance- and time-based field tests, respectively. The present meta-analysis also showed that sex, age and maximum oxygen uptake level do not seem to affect the criterion-related validity of the walk/run tests. When the evaluation of an individual's maximum oxygen uptake attained during a laboratory test is not feasible, the 1.5 mile and 12 min walk/run tests represent useful alternatives for estimating cardiorespiratory fitness. As in the assessment with any physical fitness field test, evaluators must be aware that the performance score of the walk/run field tests is simply an estimation and not a direct measure of cardiorespiratory fitness.

  2. Effect of continuous quality improvement analysis on the delivery of primary percutaneous revascularization for acute myocardial infarction: a community hospital experience.

    PubMed

    Caputo, Ronald P; Kosinski, Robert; Walford, Gary; Giambartolomei, Alex; Grant, William; Reger, Mark J; Simons, Alan; Esente, Paolo

    2005-04-01

    As time to reperfusion correlates with outcomes, a door-to-balloon time of 90 +/- 30 min for primary percutaneous coronary revascularization (PCI) for the treatment of acute myocardial infarction has been recently established as a guideline by the ACC/AHA. The purpose of this study is to assess the effects of a continuous quality assurance program designed to expedite primary angioplasty at a community hospital. A database of all primary PCI procedures was created in 1998. Two groups of consecutive patients treated with primary PCI were studied. Group 1 represented patients in the time period between 1 June 1998 to 1 November 1998 and group 2 represented patients in the period between 1 January 2000 and 16 June 2000. Continuous quality assurance analysis was performed. Modifications to the primary angioplasty program were initiated in the latter group. Time intervals to certain treatment landmarks were compared between the groups. Significant decreases in the time intervals from emergency room registration to initial electrocardiogram (8.4 +/- 8.2 vs. 3.7 +/- 19.5 min; P < 0.001), presentation to the catheterization laboratory to arterial access (13.5 +/- 12.9 vs. 11.6 +/- 5.8 min; P < 0.001), and emergency room registration to initial angioplasty balloon inflation (132.0 +/- 69.2 vs. 112 +/- 72.0 min; P < 0.001) were achieved. For the subgroup of patients presenting with diagnostic ST elevation myocardial infarction, a large decrease in the door-to-balloon time interval between group 1 and group 2 was demonstrated (114.15 +/- 9.67 vs. 87.92 +/- 10.93 min; P = NS), resulting in compliance with ACC/AHA guidelines. Continuous quality improvement analysis can expedite care for patients treated by primary PCI in the community hospital setting. Copyright 2005 Wiley-Liss, Inc.

  3. Prospective feasibility analysis of a novel off-line approach for MR-guided radiotherapy.

    PubMed

    Bostel, Tilman; Pfaffenberger, Asja; Delorme, Stefan; Dreher, Constantin; Echner, Gernot; Haering, Peter; Lang, Clemens; Splinter, Mona; Laun, Frederik; Müller, Marco; Jäkel, Oliver; Debus, Jürgen; Huber, Peter E; Sterzing, Florian; Nicolay, Nils H

    2018-05-01

    The present work aimed to analyze the feasibility of a shuttle-based MRI-guided radiation therapy (MRgRT) in the treatment of pelvic malignancies. 20 patients with pelvic malignancies were included in this prospective feasibility analysis. Patients underwent daily MRI in treatment position prior to radiotherapy at the German Cancer Research Center. Positional inaccuracies, time and patient compliance were assessed for the application of off-line MRgRT. In 78% of applied radiation fractions, MR imaging for position verification could be performed without problems. Additionally, treatment-related side effects and reduced patient compliance were only responsible for omission of MRI in 9% of radiation fractions. The study workflow took a median time of 61 min (range 47-99 min); duration for radiotherapy alone was 13 min (range 7-26 min). Patient positioning, MR imaging and CT imaging including patient repositioning and the shuttle transfer required median times of 10 min (range 7-14 min), 26 min (range 15-60 min), 5 min (range 3-8 min) and 8 min (range 2-36 min), respectively. To assess feasibility of shuttle-based MRgRT, the reference point coordinates for the x, y and z axis were determined for the MR images and CT obtained prior to the first treatment fraction and correlated with the coordinates of the planning CT. In our dataset, the median positional difference between MR imaging and CT-based imaging based on fiducial matching between MR and CT imaging was equal to or less than 2 mm in all spatial directions. The limited space in the MR scanner influenced patient selection, as the bore of the scanner had to accommodate the immobilization device and the constructed stereotactic frame. Therefore, obese, extremely muscular or very tall patients could not be included in this trial in addition to patients for whom exposure to MRI was generally judged inappropriate. This trial demonstrated for the first time the feasibility and patient compliance of a shuttle-based off-line approach to MRgRT of pelvic malignancies.

  4. [Ultraviolet radiation-induced apoptosis in human lens epithelial cells and its effect on Bcl-2 and Bax].

    PubMed

    Jia, Songbai; Shi, Jingming; Chen, Xuan; Tang, Luosheng

    2012-07-01

    To explore the apoptosis-inducing effect of ultraviolet(UV) radiation on human lens epithelial cells (HLEC), with particular focus on changes in Bcl-2 or Bax expression as possible mechanisms. All experimental groups were exposed to the same UV light source. HLEC were divided into 6 groups according to duration of UV radiation : 0 min group (control group), 5 min group, 10 min group,15 min group, and 30 min group. Analysis on apoptosis of HLEC was performed by flow cytometry analysis (FCA, Annexin V + PI staining). Changes of Bax and Bcl-2 expression in HLEC were detected by hybridization in situ. Apoptosis in HLEC increased with UV exposure time. The expression level of Bax mRNA was increased with the increase of UV exposure time, whereas the expression level of Bcl-2 mRNA decreased with the increase of UV exposure time. The proportion of apoptotic cells was negatively correlated with ratio of Bcl-2/Bax (r=-0.874, P<0.05). UA radiation can induce apoptosis of HLEC in vitro. Bcl-2 and Bax genes may play an important role in regulating this apoptotic process.

  5. Application of hydrocyanic acid vapor generation via focused microwave radiation to the preparation of industrial effluent samples prior to free and total cyanide determinations by spectrophotometric flow injection analysis.

    PubMed

    Quaresma, Maria Cristina Baptista; de Carvalho, Maria de Fátima Batista; Meirelles, Francis Assis; Santiago, Vânia Maria Junqueira; Santelli, Ricardo Erthal

    2007-02-01

    A sample preparation procedure for the quantitative determination of free and total cyanides in industrial effluents has been developed that involves hydrocyanic acid vapor generation via focused microwave radiation. Hydrocyanic acid vapor was generated from free cyanides using only 5 min of irradiation time (90 W power) and a purge time of 5 min. The HCN generated was absorbed into an accepting NaOH solution using very simple glassware apparatus that was appropriate for the microwave oven cavity. After that, the cyanide concentration was determined within 90 s using a well-known spectrophotometric flow injection analysis system. Total cyanide analysis required 15 min irradiation time (90 W power), as well as chemical conditions such as the presence of EDTA-acetate buffer solution or ascorbic acid, depending on the effluent to be analyzed (petroleum refinery or electroplating effluents, respectively). The detection limit was 0.018 mg CN l(-1) (quantification limit of 0.05 mg CN l(-1)), and the measured RSD was better than 8% for ten independent analyses of effluent samples (1.4 mg l(-1) cyanide). The accuracy of the procedure was assessed via analyte spiking (with free and complex cyanides) and by performing an independent sample analysis based on the standard methodology recommended by the APHA for comparison. The sample preparation procedure takes only 10 min for free and 20 min for total cyanide, making this procedure much faster than traditional methodologies (conventional heating and distillation), which are time-consuming (they require at least 1 h). Samples from oil (sour and stripping tower bottom waters) and electroplating effluents were analyzed successfully.

  6. Surgical site infection and timing of prophylactic antibiotics for appendectomy.

    PubMed

    Wu, Wan-Ting; Tai, Feng-Chuan; Wang, Pa-Chun; Tsai, Ming-Lin

    2014-12-01

    Pre-operative prophylactic antibiotics may decrease the frequency of surgical site infection after appendectomy. However, the optimal timing for administration of pre-operative prophylactic antibiotics is unknown. The purpose of this study was to evaluate the effect of timing of prophylactic antibiotics on the frequency of surgical site infection after appendectomy. Medical records were reviewed retrospectively for 577 consecutive patients who had appendectomy for acute appendicitis from 2006 to 2009. Quality assurance guidelines for timing of prophylactic antibiotics before the skin incision were changed from 0 to 30 min before the skin incision (before June 2008) to 30 to 60 min before the skin incision (after June 2008). Surgical site infection occurred in 28 patients (4.9%). There was no difference in frequency of surgical site infection with different timing of pre-operative prophylactic antibiotic (pre-operative time 0 to 30 min: 9 infections [3.6%]; 31 to 60 min: 13 infections [5.4%]; 61 to 120 min: 5 infections [7.0%]; >120 min: 1 infection [6.6%]). Multivariable analysis showed that surgical site infection was associated significantly with medical comorbidity but not perforated appendicitis. The frequency of surgical site infection was independent of timing of preoperative prophylactic antibiotics but was associated with the presence of medical comorbidity.

  7. Agonal sequences in eight filmed hangings: analysis of respiratory and movement responses to asphyxia by hanging.

    PubMed

    Sauvageau, Anny; LaHarpe, Romano; Geberth, Vernon J

    2010-09-01

    It has been proposed that filmed hangings may hold the key to a better understanding of human asphyxia, and The Working Group on Human Asphyxia was formed to systematically review and compare these video recordings. This study analyzed eight filmed hangings. Considering time 0 to represent the onset of the final hanging, rapid loss of consciousness was observed (at 8-18 sec), closely followed by convulsions (at 10-19 sec). A complex pattern of decerebrate rigidity and decorticate rigidity then followed. Between 1 min 38 sec and 2 min 15 sec, muscle tone seemed to be lost, the body becoming progressively flaccid. From then on, isolated body movements were observed from time to time, the last one occurring between 1 min 2 sec and 7 min 31 sec. As for the respiratory responses, all cases presented deep rhythmic abdominal respiratory movements (last one between 1 min 2 sec and 2 min 5 sec). © 2010 American Academy of Forensic Sciences.

  8. Shortened acquisition protocols for the quantitative assessment of the 2-tissue-compartment model using dynamic PET/CT 18F-FDG studies.

    PubMed

    Strauss, Ludwig G; Pan, Leyun; Cheng, Caixia; Haberkorn, Uwe; Dimitrakopoulou-Strauss, Antonia

    2011-03-01

    (18)F-FDG kinetics are quantified by a 2-tissue-compartment model. The routine use of dynamic PET is limited because of this modality's 1-h acquisition time. We evaluated shortened acquisition protocols up to 0-30 min regarding the accuracy for data analysis with the 2-tissue-compartment model. Full dynamic series for 0-60 min were analyzed using a 2-tissue-compartment model. The time-activity curves and the resulting parameters for the model were stored in a database. Shortened acquisition data were generated from the database using the following time intervals: 0-10, 0-16, 0-20, 0-25, and 0-30 min. Furthermore, the impact of adding a 60-min uptake value to the dynamic series was evaluated. The datasets were analyzed using dedicated software to predict the results of the full dynamic series. The software is based on a modified support vector machines (SVM) algorithm and predicts the compartment parameters of the full dynamic series. The SVM-based software provides user-independent results and was accurate at predicting the compartment parameters of the full dynamic series. If a squared correlation coefficient of 0.8 (corresponding to 80% explained variance of the data) was used as a limit, a shortened acquisition of 0-16 min was accurate at predicting the 60-min 2-tissue-compartment parameters. If a limit of 0.9 (90% explained variance) was used, a dynamic series of at least 0-20 min together with the 60-min uptake values is required. Shortened acquisition protocols can be used to predict the parameters of the 2-tissue-compartment model. Either a dynamic PET series of 0-16 min or a combination of a dynamic PET/CT series of 0-20 min and a 60-min uptake value is accurate for analysis with a 2-tissue-compartment model.

  9. Analysis of Investigational Drugs in Biological Fluids. Method Development and Routine Assay. Appendix A.

    DTIC Science & Technology

    1997-02-13

    AMINOPROPIOPHENONE IN DOG PLASMA 0 OCH 3 CH2 CH3 OCH2CHOHCH 2 OH H2 N& p-Aminopropiophenone Guaifenesin (WR 000,302) Internal Standard APPROVALS: This Analytical...40 - 80 il VOLUME: RUN TIME: 14 min (PAPP: 10.7 min; Guaifenesin (Internal Standard): 8.5 min) DETECTOR Wavelength: 316 nm SETTINGS: Absorption Range

  10. Correcting (18)F-fluoride PET static scan measurements of skeletal plasma clearance for tracer efflux from bone.

    PubMed

    Siddique, Musib; Frost, Michelle L; Moore, Amelia E B; Fogelman, Ignac; Blake, Glen M

    2014-03-01

    The aim of the study was to examine whether (18)F-fluoride PET ((18)F-PET) static scan measurements of bone plasma clearance (Ki) can be corrected for tracer efflux from bone from the time of injection. The efflux of tracer from bone mineral to plasma was described by a first-order rate constant kloss. A modified Patlak analysis was applied to 60-min dynamic (18)F-PET scans of the spine and hip acquired during trials on the bone anabolic agent teriparatide to find the best-fit values of kloss at the lumbar spine, total hip and femoral shaft. The resulting values of kloss were used to extrapolate the modified Patlak plots to 120 min after injection and derive a sequence of static scan estimates of Ki at 4-min intervals that were compared with the Patlak Ki values from the 60-min dynamic scans. A comparison was made with the results of the standard static scan analysis, which assumes kloss=0. The best-fit values of kloss for the spine and hip regions of interest averaged 0.006/min and did not change when patients were treated with teriparatide. Static scan values of Ki calculated using the modified analysis with kloss=0.006/min were independent of time between 10 and 120 min after injection and were in close agreement with findings from the dynamic scans. In contrast, by 2 h after injection the static scan Ki values calculated using the standard analysis underestimated the dynamic scan results by 20%. Using a modified analysis that corrects for F efflux from bone, estimates of Ki from static PET scans can be corrected for time up to 2 h after injection. This simplified approach may obviate the need to perform dynamic scans and hence shorten the scanning procedure for the patient and reduce the cost of studies. It also enables reliable estimates of Ki to be obtained from multiple skeletal sites with a single injection of tracer.

  11. Energy dependence of SEP electron and proton onset times

    NASA Astrophysics Data System (ADS)

    Xie, H.; Mäkelä, P.; Gopalswamy, N.; St. Cyr, O. C.

    2016-07-01

    We study the large solar energetic particle (SEP) events that were detected by GOES in the >10 MeV energy channel during December 2006 to March 2014. We derive and compare solar particle release (SPR) times for the 0.25-10.4 MeV electrons and 10-100 MeV protons for the 28 SEP events. In the study, the electron SPR times are derived with the time-shifting analysis (TSA) and the proton SPR times are derived using both the TSA and the velocity dispersion analysis (VDA). Electron anisotropies are computed to evaluate the amount of scattering for the events under study. Our main results include (1) near-relativistic electrons and high-energy protons are released at the same time within 8 min for most (16 of 23) SEP events. (2)There exists a good correlation between electron and proton acceleration, peak intensity, and intensity time profiles. (3) The TSA SPR times for 90.5 MeV and 57.4 MeV protons have maximum errors of 6 min and 10 min compared to the proton VDA release times, respectively, while the maximum error for 15.4 MeV protons can reach to 32 min. (4) For 7 low-intensity events of the 23, large delays occurred for 6.5 MeV electrons and 90.5 MeV protons relative to 0.5 MeV electrons. Whether these delays are due to times needed for the evolving shock to be strengthened or due to particle transport effects remains unsolved.

  12. Predictor variables of performance in recreational male long-distance inline skaters.

    PubMed

    Knechtle, Beat; Knechtle, Patrizia; Rüst, Christoph Alexander; Senn, Oliver; Rosemann, Thomas; Lepers, Romuald

    2011-06-01

    We investigated the associations between selected anthropometric and training characteristics with race time in 84 recreational male long-distance inline skaters at the longest inline marathon in Europe, the 'Inline One-eleven' over 111 km in Switzerland, using bi- and multivariate analysis. The mean (s) race time was 264 (41) min. The bivariate analysis showed that age (r = 0.30), body mass (r = 0.42), body mass index (r = 0.35), circumference of upper arm (r = 0.32), circumference of thigh (r = 0.29), circumference of calf (r = 0.38), skin-fold of thigh (r = 0.22), skin-fold of calf (r = 0.27), the sum of skin-folds (r = 0.43), percent body fat (r = 0.45), duration per training unit in inline skating (r = 0.33), and speed during training (r = -0.46) were significantly and positively correlated to race time. Stepwise multiple regression showed that duration per training unit (P = 0.003), age (P = 0.029) and percent body fat (P = 0.016) were the best correlated with race time. Race time in a long-distance inline race such as the 'Inline One-eleven' over 111 km with a mean race time of ∼260 min might be predicted by the following equation (r(2) = 0.41): Race time (min) = 114.91 + 0:51* (duration per training unit, min) + 0:85* (age, years) +3:78* (body fat, %) for recreational long-distance inline skaters.

  13. ANALYSIS OF STANDARD MULTI-PORT VS. SINGLE SITE ACCESS FOR LAPAROSCOPIC SKILLS TRAINING

    PubMed Central

    Cox, Daniel R; Zeng, Wenjing; Frisella, Margaret M; Brunt, L. Michael

    2015-01-01

    Introduction Single site access (SSA) laparoscopy is more challenging to perform than multi-port(MP) laparoscopy. We examined MP versus SSA skills training on laparoscopic performance in surgically naive individuals. Methods Forty end-of-1st year medical students were randomized into two groups. Both were trained on 4 basic laparoscopic drills (peg, rope, bean drop, pattern cutting) using a standard MP setup (Group 1) or SSA approach (Group 2). Time to proficiency and number of repetitions (reps) were recorded. Each group then crossed over to the alternate approach where the sequence was repeated. Data are mean ± SD and statistical analysis was with two-tailed, unpaired t-test. Results Total times to proficiency for the SSA and MP approaches was not significantly different between groups (Group 1 M-P 234.0 ± 114.9 min vs Group 2 SSA 216.4 ± 106.5 min, p=0.67). The MP-trained group took less time to reach proficiency on the standard MP setup than the SSA group on the SSA approach (119.1 ± 69.7 min vs 178.0 ± 93.4 min, p=0.058) with significantly fewer repetitions (77.6 ± 42.6 vs. 118.8 ± 54.3, p=0.027). The SSA-trained group took significantly less time to reach proficiency on the MP setup than the standard MP-trained group (38.4 ± 29.4 min vs. 119.1 ± 69.7 min; p=0.0013) requiring only a mean of 26.9 total repetitions. When the standard MP group crossed over to the SSA setup, they took significantly less time to reach proficiency with the SSA approach than the SSA-trained group (114.8 ± 50.5 min vs. 178.0 ± 93.4 min, p=0.026) but with more total repetitions than with the M-P approach (86.2 ± 35.2 vs 77.6 ± 42.6, p= NS). Conclusions Laparoscopic single site access skills training results in longer times and more repetitions to achieve proficiency than multi-port training, but the skills acquired transfer well to the multi-port approach. PMID:20872019

  14. The 'pit-crew' model for improving door-to-needle times in endovascular stroke therapy: a Six-Sigma project.

    PubMed

    Rai, Ansaar T; Smith, Matthew S; Boo, SoHyun; Tarabishy, Abdul R; Hobbs, Gerald R; Carpenter, Jeffrey S

    2016-05-01

    Delays in delivering endovascular stroke therapy adversely affect outcomes. Time-sensitive treatments such as stroke interventions benefit from methodically developed protocols. Clearly defined roles in these protocols allow for parallel processing of tasks, resulting in consistent delivery of care. To present the outcomes of a quality-improvement (QI) process directed at reducing stroke treatment times in a tertiary level academic medical center. A Six-Sigma-based QI process was developed over a 3-month period. After an initial analysis, procedures were implemented and fine-tuned to identify and address rate-limiting steps in the endovascular care pathway. Prospectively recorded treatment times were then compared in two groups of patients who were treated 'before' (n=64) or 'after' (n=30) the QI process. Three time intervals were measured: emergency room (ER) to arrival for CT scan (ER-CT), CT scan to interventional laboratory arrival (CT-Lab), and interventional laboratory arrival to groin puncture (Lab-puncture). The ER-CT time was 40 (±29) min in the 'before' and 26 (±15) min in the 'after' group (p=0.008). The CT-Lab time was 87 (±47) min in the 'before' and 51 (±33) min in the 'after' group (p=0.0002). The Lab-puncture time was 24 (±11) min in the 'before' and 15 (±4) min in the 'after' group (p<0.0001). The overall ER-arrival to groin-puncture time was reduced from 2 h, 31 min (±51) min in the 'before' to 1 h, 33 min (±37) min in the 'after' group, (p<0.0001). The improved times were seen for both working hours and off-hours interventions. A protocol-driven process can significantly improve efficiency of care in time-sensitive stroke interventions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  15. The fluoroscopy time, door to balloon time, contrast volume use and prevalence of vascular access site failure with transradial versus transfemoral approach in ST segment elevation myocardial infarction: A systematic review & meta-analysis.

    PubMed

    Singh, Sukhchain; Singh, Mukesh; Grewal, Navsheen; Khosla, Sandeep

    2015-12-01

    The authors aimed to conduct first systematic review and meta-analysis in STEMI patients evaluating vascular access site failure rate, fluoroscopy time, door to balloon time and contrast volume used with transradial vs transfemoral approach (TRA vs TFA) for PCI. The PubMed, CINAHL, clinicaltrials.gov, Embase and CENTRAL databases were searched for randomized trials comparing TRA versus TFA. Random effect models were used to conduct this meta-analysis. Fourteen randomized trials comprising 3758 patients met inclusion criteria. The access site failure rate was significantly higher TRA compared to TFA (RR 3.30, CI 2.16-5.03; P=0.000). Random effect inverse variance weighted prevalence rate meta-analysis showed that access site failure rate was predicted to be 4% (95% CI 3.0-6.0%) with TRA versus 1% (95% CI 0.0-1.0 %) with TFA. Door to balloon time (Standardized mean difference [SMD] 0.30 min, 95% CI 0.23-0.37 min; P=0.000) and fluoroscopy time (Standardized mean difference 0.14 min, 95% CI 0.06-0.23 min; P=0.001) were also significantly higher in TRA. There was no difference in the amount of contrast volume used with TRA versus TFA (SMD -0.05 ml, 95% CI -0.14 to 0.04 ml; P=0.275). Statistical heterogeneity was low in cross-over rate and contrast volume use, moderate in fluoroscopy time but high in the door to balloon time comparison. Operators need to consider higher cross-over rate with TRA compared to TFA in STEMI patients while attempting PCI. Fluoroscopy and door to balloon times are negligibly higher with TRA but there is no difference in terms of contrast volume use. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Predicting Vasovagal Syncope from Heart Rate and Blood Pressure: A Prospective Study in 140 Subjects.

    PubMed

    Virag, Nathalie; Erickson, Mark; Taraborrelli, Patricia; Vetter, Rolf; Lim, Phang Boon; Sutton, Richard

    2018-04-28

    We developed a vasovagal syncope (VVS) prediction algorithm for use during head-up tilt with simultaneous analysis of heart rate (HR) and systolic blood pressure (SBP). We previously tested this algorithm retrospectively in 1155 subjects, showing sensitivity 95%, specificity 93% and median prediction time of 59s. This study was prospective, single center, on 140 subjects to evaluate this VVS prediction algorithm and assess if retrospective results were reproduced and clinically relevant. Primary endpoint was VVS prediction: sensitivity and specificity >80%. In subjects, referred for 60° head-up tilt (Italian protocol), non-invasive HR and SBP were supplied to the VVS prediction algorithm: simultaneous analysis of RR intervals, SBP trends and their variability represented by low-frequency power generated cumulative risk which was compared with a predetermined VVS risk threshold. When cumulative risk exceeded threshold, an alert was generated. Prediction time was duration between first alert and syncope. Of 140 subjects enrolled, data was usable for 134. Of 83 tilt+ve (61.9%), 81 VVS events were correctly predicted and of 51 tilt-ve subjects (38.1%), 45 were correctly identified as negative by the algorithm. Resulting algorithm performance was sensitivity 97.6%, specificity 88.2%, meeting primary endpoint. Mean VVS prediction time was 2min 26s±3min16s with median 1min 25s. Using only HR and HR variability (without SBP) the mean prediction time reduced to 1min34s±1min45s with median 1min13s. The VVS prediction algorithm, is clinically-relevant tool and could offer applications including providing a patient alarm, shortening tilt-test time, or triggering pacing intervention in implantable devices. Copyright © 2018. Published by Elsevier Inc.

  17. Automatic updating of times remaining in surgical cases using bayesian analysis of historical case duration data and "instant messaging" updates from anesthesia providers.

    PubMed

    Dexter, Franklin; Epstein, Richard H; Lee, John D; Ledolter, Johannes

    2009-03-01

    Operating room (OR) whiteboards (status displays) communicate times remaining for ongoing cases to perioperative stakeholders (e.g., postanesthesia care unit, anesthesiologists, holding area, and control desks). Usually, scheduled end times are shown for each OR. However, these displays are inaccurate for predicting the time that remains in a case. Once a case scheduled for 2 h has been on-going for 1.5 h, the median time remaining is not 0.5 h but longer, and the amount longer differs among procedures. We derived the conditional Bayesian lower prediction bound of a case's duration, conditional on the minutes of elapsed OR time. Our derivations make use of the posterior predictive distribution of OR times following an exponential of a scaled Student t distribution that depends on the scheduled OR time and several parameters calculated from historical case duration data. The statistical method was implemented using Structured Query Language (SQL) running on the anesthesia information management system (AIMS) database server. In addition, AIMS workstations were sent instant messages displaying a pop-up dialog box asking for anesthesia providers' estimates for remaining times. The dialogs caused negotiated interruptions (i.e., the anesthesia provider could reply immediately, keep the dialog displayed, or defer response). There were no announcements, education, or efforts to promote buy-in. After a case had been in the OR longer than scheduled, the median remaining OR time for the case changes little over time (e.g., 35 min left at 2:30 pm and also at 3:00 pm while the case was still on-going). However, the remaining time differs substantially among surgeons and scheduled procedure(s) (16 min longer [10th percentile], 35 min [50th], and 86 min [90th]). We therefore implemented an automatic method to estimate the times remaining in cases. The system was operational for >119 of each day's 120 5-min intervals. When instant message dialogs appearing on AIMS workstations were used to elicit estimates of times remaining from anesthesia providers, acknowledgment was on average within 1.2 min (95% confidence interval [CI] 1.1-1.3 min). The 90th percentile of latencies was 6.5 min (CI: 4.4-7.0 min). For cases taking nearly as long as or longer than scheduled, each 1 min progression of OR time reduces the median time remaining in a case by <1 min. We implemented automated calculation of times remaining for every case at a 29 OR hospital.

  18. Prediction of lactate threshold and fixed blood lactate concentrations from 3200-m running performance in male runners.

    PubMed

    Weltman, A; Snead, D; Seip, R; Schurrer, R; Levine, S; Rutt, R; Reilly, T; Weltman, J; Rogol, A

    1987-12-01

    To determine the effectiveness of a 3200-m time trial for predicting VO2 and running velocity at lactate threshold (LT), fixed blood lactate concentrations of 2.0, 2.5, and 4.0 mM, and peak, 42 male runners (means age = 31.1 +/- 8.3 years; means ht = 176.8 +/- 6.6 cm; means wt = 70.4 +/- 10.0 kg) completed a VO2 peak/LT test and a 3200-m time trial. The continuous treadmill protocol started at 0% grade 150 m/min and increased 10 m/min every 3 min until exhaustion. Velocity at LT, 2.0, 2.5, and 4.0 mM was determined from individual velocity blood lactate relationships, and VO2 values were determined from individual plots ov VO2 vs velocity. VO2 peak and velocity peak were chosen as the highest values observed. Oxygen uptake at LT, 2.0, 2.5, 4.0 mM, and peak was 52.51, 56.61, 58.31, 61.70, and 64.21 ml/kg.min-1, respectively, while the velocities associated with LT, 2.0, 2.5, 4.0 mM, and peak were 235.5, 251.5, 259.8, 273.5, and 285.5 m/min, respectively. During the 3200-m time trial (means time = 11.28 +/- 0.96 min), 400-m split times and cumulative times were recorded. Twenty-nine subjects were randomly assigned to a validation sample and the remaining subjects were used for cross-validation purposes. Regression analysis revealed that a 3200-m time trial was a good predictor of both VO2 (ml/kg.min-1) and velocity (m/min) at LT, 2.0, 2.5, 4.0 mM, and peak.

  19. Minimal Window Duration for Accurate HRV Recording in Athletes.

    PubMed

    Bourdillon, Nicolas; Schmitt, Laurent; Yazdani, Sasan; Vesin, Jean-Marc; Millet, Grégoire P

    2017-01-01

    Heart rate variability (HRV) is non-invasive and commonly used for monitoring responses to training loads, fitness, or overreaching in athletes. Yet, the recording duration for a series of RR-intervals varies from 1 to 15 min in the literature. The aim of the present work was to assess the minimum record duration to obtain reliable HRV results. RR-intervals from 159 orthostatic tests (7 min supine, SU, followed by 6 min standing, ST) were analyzed. Reference windows were 4 min in SU (min 3-7) and 4 min in ST (min 9-13). Those windows were subsequently divided and the analyses were repeated on eight different fractioned windows: the first min (0-1), the second min (1-2), the third min (2-3), the fourth min (3-4), the first 2 min (0-2), the last 2 min (2-4), the first 3 min (0-3), and the last 3 min (1-4). Correlation and Bland & Altman statistical analyses were systematically performed. The analysis window could be shortened to 0-2 instead of 0-4 for RMSSD only, whereas the 4-min window was necessary for LF and total power. Since there is a need for 1 min of baseline to obtain a steady signal prior the analysis window, we conclude that studies relying on RMSSD may shorten the windows to 3 min (= 1+2) in SU or seated position only and to 6 min (= 1+2 min SU plus 1+2 min ST) if there is an orthostatic test. Studies relying on time- and frequency-domain parameters need a minimum of 5 min (= 1+4) min SU or seated position only but require 10 min (= 1+4 min SU plus 1+4 min ST) for the orthostatic test.

  20. Impact of perioperative blood pressure variability on health resource utilization after cardiac surgery: an analysis of the ECLIPSE trials.

    PubMed

    Aronson, Solomon; Levy, Jerrold H; Lumb, Philip D; Fontes, Manuel; Wang, Yamei; Crothers, Tracy A; Sulham, Katherine A; Navetta, Marco S

    2014-06-01

    To examine the impact of blood pressure control on hospital health resource utilization using data from the ECLIPSE trials. Post-hoc analysis of data from 3 prospective, open-label, randomized clinical trials (ECLIPSE trials). Sixty-one medical centers in the United States. Patients 18 years or older undergoing cardiac surgery. Clevidipine was compared with nitroglycerin, sodium nitroprusside, and nicardipine. The ECLIPSE trials included 3 individual randomized open-label studies comparing clevidipine to nitroglycerin, sodium nitroprusside, and nicardipine. Blood pressure control was assessed as the integral of the cumulative area under the curve (AUC) outside specified systolic blood pressure ranges, such that lower AUC represents less variability. This analysis examined surgery duration, time to extubation, as well as intensive care unit (ICU) and hospital length of stay (LOS) in patients with AUC≤10 mmHg×min/h compared to patients with AUC>10 mmHg×min/h. One thousand four hundred ten patients were included for analysis; 736 patients (52%) had an AUC≤10 mmHg×min/h, and 674 (48%) had an AUC>10 mmHg×min/h. The duration of surgery and ICU LOS were similar between groups. Time to extubation and postoperative LOS were both significantly shorter (p = 0.05 and p<0.0001, respectively) in patients with AUC≤10. Multivariate analysis demonstrates AUC≤10 was significantly and independently associated with decreased time to extubation (hazard ratio 1.132, p = 0.0261) and postoperative LOS (hazard ratio 1.221, p = 0.0006). Based on data derived from the ECLIPSE studies, increased perioperative BP variability is associated with delayed time to extubation and increased postoperative LOS. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. The enhancement in electrical analysis of the nitrogen doped amorphous carbon thin films (a-C:N) prepared by aerosol-assisted CVD

    NASA Astrophysics Data System (ADS)

    Fadzilah, A. N.; Dayana, K.; Rusop, M.

    2018-05-01

    This paper reports on the deposition of Nitrogen doped amorphous carbon (a-C:N) by Aerosol-assisted Chemical Vapor Deposition (AACVD) using natural source of camphor oil as the precursor material. 5 samples were deposited at 5 different deposition times from 15 min to 90 min, with 15 min interval for each sample. The highest slope of linear graph was noted at the sample with 45 min deposition time, showing the lowest electrical resistance of the sample. From I-V characteristic, the sample deposited at 45 min has the highest electrical conductivity due to high sp2 carbon bonding ratio. Nanostructured behavior of N doped a-C:N was also investigated by FESEM micrograph resulting with the particle size less than 100nm.

  2. Analysis of reperfusion time trends in patients with ST-elevation myocardial infarction across New York State from 2004 to 2012.

    PubMed

    Al'Aref, Subhi J; Wong, S Chiu; Swaminathan, Rajesh V; McNair, Patrick; Feldman, Dmitriy N; Kim, Luke K; Singh, Harsimran S; Bergman, Geoffrey; Minutello, Robert M

    2017-04-01

    Registry-driven data have shown a significant decrease in door-to-balloon (DTB) times in patients with ST-elevation myocardial infarction (STEMI) receiving percutaneous coronary intervention (PCI). We sought to determine the trends in reperfusion times (symptom-onset to door (SOTD) and DTB times) in patients presenting with STEMI across New York State. We retrospectively examined 35,613 STEMI patients receiving PCI from 2004 to 2012 and compared median SOTD and DTB times across years. Patients with SOTD time >12h and DTB time >3h were excluded. There was a statistically significant trend towards shorter DTB times (median DTB time of 83min (IQR 53, 116) in 2004 to a median DTB time of 59min (IQR 40, 78) in 2012, P<0.01 for trend) and SOTD times (median SOTD time of 127min (IQR 64, 241) in 2004 to a median SOTD time of 116min (IQR 60, 205) in 2012, P<0.01 for trend). In subgroup analysis, demographics and the presence of co-morbid conditions did not influence the trend in reperfusion times. However, women had longer reperfusion times than men in 2012. After adjusting for confounding variables, DTB was a significant predictor of in-hospital mortality (HR=1.04 (per 10minutes), P<0.01). There was a significant decrease in reperfusion times from 2004 to 2012 in STEMI patients across New York State. This trend was significant regardless of the presence of co-morbid conditions, although a significant gap in reperfusion times persists between men and women. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Criterion-Related Validity of the Distance- and Time-Based Walk/Run Field Tests for Estimating Cardiorespiratory Fitness: A Systematic Review and Meta-Analysis

    PubMed Central

    Mayorga-Vega, Daniel; Bocanegra-Parrilla, Raúl; Ornelas, Martha; Viciana, Jesús

    2016-01-01

    Objectives The main purpose of the present meta-analysis was to examine the criterion-related validity of the distance- and time-based walk/run tests for estimating cardiorespiratory fitness among apparently healthy children and adults. Materials and Methods Relevant studies were searched from seven electronic bibliographic databases up to August 2015 and through other sources. The Hunter-Schmidt’s psychometric meta-analysis approach was conducted to estimate the population criterion-related validity of the following walk/run tests: 5,000 m, 3 miles, 2 miles, 3,000 m, 1.5 miles, 1 mile, 1,000 m, ½ mile, 600 m, 600 yd, ¼ mile, 15 min, 12 min, 9 min, and 6 min. Results From the 123 included studies, a total of 200 correlation values were analyzed. The overall results showed that the criterion-related validity of the walk/run tests for estimating maximum oxygen uptake ranged from low to moderate (rp = 0.42–0.79), with the 1.5 mile (rp = 0.79, 0.73–0.85) and 12 min walk/run tests (rp = 0.78, 0.72–0.83) having the higher criterion-related validity for distance- and time-based field tests, respectively. The present meta-analysis also showed that sex, age and maximum oxygen uptake level do not seem to affect the criterion-related validity of the walk/run tests. Conclusions When the evaluation of an individual’s maximum oxygen uptake attained during a laboratory test is not feasible, the 1.5 mile and 12 min walk/run tests represent useful alternatives for estimating cardiorespiratory fitness. As in the assessment with any physical fitness field test, evaluators must be aware that the performance score of the walk/run field tests is simply an estimation and not a direct measure of cardiorespiratory fitness. PMID:26987118

  4. Thermal analysis of a planetary transmission with spherical roller bearings operating after complete loss of oil

    NASA Technical Reports Server (NTRS)

    Coe, H. H.

    1984-01-01

    Planetsys and Spherbean, two computer programs developed for the analysis of rolling element bearings, were used to simulate the thermal performance of an OH-58 helicopter main rotor transmission. A steady state and a transient thermal analysis were made and temperatures thus calculated were compared with experimental data obtained from a transmission that was operated to destruction, which occurred about 30 min after all the oil was drained from the transmission. Temperatures predicted by Spherbean were within 3% of the corresponding measured values at 15 min elapsed time and within 9% at 25 min. Spherbean also indicates a potential for high bearing cage temperatures with misalignment and outer ring rotation.

  5. Intrathecal dexmedetomidine as adjuvant for spinal anaesthesia for perianal ambulatory surgeries: A randomised double-blind controlled study.

    PubMed

    Nethra, S S; Sathesha, M; Dixit, Aanchal; Dongare, Pradeep A; Harsoor, S S; Devikarani, D

    2015-03-01

    The newer trend in regional anaesthesia for ambulatory anorectal surgeries advocate use of lower dose of local anaesthetic, providing segmental block with adjuvants such as opioids and α2 agonists to prolong analgesia. The current study investigated effects of addition of 5 μg of dexmedetomidine to 6 mg of hyperbaric bupivacaine on duration of analgesia, sensory and motor block characteristics for perianal ambulatory surgeries. This study is a prospective randomised controlled double blind study. Forty adult patients between 18 and 55 years of age were divided into 2 groups. Group D received intrathecal 0.5% hyperbaric bupivacaine 6 mg (1.2 ml) with injection dexmedetomidine 5 μg in 0.5 ml of normal saline and Group N received intrathecal 0.5% hyperbaric bupivacaine 6 mg (1.2 ml) with 0.5 ml of normal saline. The parameters assessed were time to regression of sensory blockade, motor blockade, ambulation, time to void, first administration of analgesic. Statistical analysis was done using appropriate tests. Time for regression of sensory level and time for first administration of analgesic were prolonged in Group D (430.05 ± 89.13 min, 459.8 ± 100.9 min, respectively) in comparison to Group N (301.10 ± 94.86 min, 321.85 ± 95.08 min, respectively). However, the duration of motor blockade, time to ambulation, and time to void were also significantly prolonged in Group D (323.05 ± 54.58 min, 329.55 ± 54.06 min, 422.30 ± 87.59 min) than in Group N (220.10 ± 63.61 min, 221.60 ± 63.84 min, 328.45 ± 113.38 min). Intrathecal dexmedetomidine 5 μg added to intrathecal bupivacaine 6 mg as adjuvant may not be suitable for ambulatory perianal surgeries due to prolongation of motor blockade.

  6. A mathematical model of diurnal variations in human plasma melatonin levels

    NASA Technical Reports Server (NTRS)

    Brown, E. N.; Choe, Y.; Shanahan, T. L.; Czeisler, C. A.

    1997-01-01

    Studies in animals and humans suggest that the diurnal pattern in plasma melatonin levels is due to the hormone's rates of synthesis, circulatory infusion and clearance, circadian control of synthesis onset and offset, environmental lighting conditions, and error in the melatonin immunoassay. A two-dimensional linear differential equation model of the hormone is formulated and is used to analyze plasma melatonin levels in 18 normal healthy male subjects during a constant routine. Recently developed Bayesian statistical procedures are used to incorporate correctly the magnitude of the immunoassay error into the analysis. The estimated parameters [median (range)] were clearance half-life of 23.67 (14.79-59.93) min, synthesis onset time of 2206 (1940-0029), synthesis offset time of 0621 (0246-0817), and maximum N-acetyltransferase activity of 7.17(2.34-17.93) pmol x l(-1) x min(-1). All were in good agreement with values from previous reports. The difference between synthesis offset time and the phase of the core temperature minimum was 1 h 15 min (-4 h 38 min-2 h 43 min). The correlation between synthesis onset and the dim light melatonin onset was 0.93. Our model provides a more physiologically plausible estimate of the melatonin synthesis onset time than that given by the dim light melatonin onset and the first reliable means of estimating the phase of synthesis offset. Our analysis shows that the circadian and pharmacokinetics parameters of melatonin can be reliably estimated from a single model.

  7. Daytime Napping and the Risk of Cardiovascular Disease and All-Cause Mortality: A Prospective Study and Dose-Response Meta-Analysis.

    PubMed

    Yamada, Tomohide; Hara, Kazuo; Shojima, Nobuhiro; Yamauchi, Toshimasa; Kadowaki, Takashi

    2015-12-01

    To summarize evidence about the association between daytime napping and the risk of cardiovascular disease and all-cause mortality, and to quantify the potential dose-response relation. Meta-analysis of prospective cohort studies. Electronic databases were searched for articles published up to December 2014 using the terms nap, cardiovascular disease, and all-cause mortality. We selected well-adjusted prospective cohort studies reporting risk estimates for cardiovascular disease and all-cause mortality related to napping. Eleven prospective cohort studies were identified with 151,588 participants (1,625,012 person-years) and a mean follow-up period of 11 years (60% women, 5,276 cardiovascular events, and 18,966 all-cause deaths). Pooled analysis showed that a long daytime nap (≥ 60 min/day) was associated with a higher risk of cardiovascular disease (rate ratio [RR]: 1.82 [1.22-2.71], P = 0.003, I(2) = 37%) compared with not napping. All-cause mortality was associated with napping for ≥ 60 min/day (RR: 1.27 [1.11-1.45], P < 0.001, I(2) = 0%) compared with not napping. In contrast, napping for < 60 min/day was not associated with cardiovascular disease (P = 0.98) or all-cause mortality (P = 0.08). Meta-analysis demonstrated a significant J-curve dose-response relation between nap time and cardiovascular disease (P for nonlinearity = 0.01). The RR initially decreased from 0 to 30 min/day. Then it increased slightly until about 45 min/day, followed by a sharp increase at longer nap times. There was also a positive linear relation between nap time and all-cause mortality (P for non-linearity = 0.97). Nap time and cardiovascular disease may be associated via a J-curve relation. Further studies are needed to confirm the efficacy of a short nap. © 2015 Associated Professional Sleep Societies, LLC.

  8. Anterolateral minithoracotomy versus median sternotomy for the treatment of congenital heart defects: a meta-analysis and systematic review.

    PubMed

    Ding, Chao; Wang, Chunmao; Dong, Aiqiang; Kong, Minjian; Jiang, Daming; Tao, Kaiyu; Shen, Zhonghua

    2012-05-04

    Anterolateral Minithoracotomy (ALMT) for the radical correction of Congenital Heart Defects is an alternative to Median Sternotomy (MS) due to reduce operative trauma accelerating recovery and yield a better cosmetic outcome after surgery. Our purpose is to conduct whether ALMT would bring more short-term benefits to patients than conventional Median Sternotomy by using a meta-analysis of case-control study in the published English Journal. 6 case control studies published in English from 1997 to 2011 were identified and synthesized to compare the short-term postoperative outcomes between ALMT and MS. These outcomes were cardiopulmonary bypass time, aortic cross-clamp time, intubation time, intensive care unit stay time, and postoperative hospital stay time. ALMT had significantly longer cardiopulmonary bypass times (8.00 min more, 95% CI 0.36 to 15.64 min, p = 0.04). Some evidence proved that aortic cross-clamp time of ALMT was longer, yet not significantly (2.38 min more, 95% CI -0.15 to 4.91 min, p = 0.06). In addition, ALMT had significantly shorter intubation time (1.66 hrs less, 95% CI -3.05 to -0.27 hrs, p = 0.02). Postoperative hospital stay time was significantly shorter with ALMT (1.52 days less, 95% CI -2.71 to -0.33 days, p = 0.01). Some evidence suggested a reduction in ICU stay time in the ALMT group. However, this did not prove to be statistically significant (0.88 days less, 95% CI -0.81 to 0.04 days, p = 0.08). ALMT can bring more benefits to patients with Congenital Heart Defects by reducing intubation time and postoperative hospital stay time, though ALMT has longer CPB time and aortic cross-clamp time.

  9. Comparison of myocardial perfusion imaging between the new high-speed gamma camera and the standard anger camera.

    PubMed

    Tanaka, Hirokazu; Chikamori, Taishiro; Hida, Satoshi; Uchida, Kenji; Igarashi, Yuko; Yokoyama, Tsuyoshi; Takahashi, Masaki; Shiba, Chie; Yoshimura, Mana; Tokuuye, Koichi; Yamashina, Akira

    2013-01-01

    Cadmium-zinc-telluride (CZT) solid-state detectors have been recently introduced into the field of myocardial perfusion imaging. The aim of this study was to prospectively compare the diagnostic performance of the CZT high-speed gamma camera (Discovery NM 530c) with that of the standard 3-head gamma camera in the same group of patients. The study group consisted of 150 consecutive patients who underwent a 1-day stress-rest (99m)Tc-sestamibi or tetrofosmin imaging protocol. Image acquisition was performed first on a standard gamma camera with a 15-min scan time each for stress and for rest. All scans were immediately repeated on a CZT camera with a 5-min scan time for stress and a 3-min scan time for rest, using list mode. The correlations between the CZT camera and the standard camera for perfusion and function analyses were strong within narrow Bland-Altman limits of agreement. Using list mode analysis, image quality for stress was rated as good or excellent in 97% of the 3-min scans, and in 100% of the ≥4-min scans. For CZT scans at rest, similarly, image quality was rated as good or excellent in 94% of the 1-min scans, and in 100% of the ≥2-min scans. The novel CZT camera provides excellent image quality, which is equivalent to standard myocardial single-photon emission computed tomography, despite a short scan time of less than half of the standard time.

  10. Residential Environment for Outdoor Play Among Children in Latino Farmworker Families.

    PubMed

    Arcury, Thomas A; Suerken, Cynthia K; Ip, Edward H; Moore, Justin B; Quandt, Sara A

    2017-04-01

    Child health and development benefit from physical activity. This analysis describes the residential play environment for children aged 2-4 years in farmworker families, their parent-reported levels of play and media time, and the association of residential environment with play and media time. Mothers with a child aged 2-4 years in farmworker families (n = 248) completed interviews over 2 years. Outcome measures were daily outdoor play time and media time. Measures of the residential environment included physical and social components. The mean min/day for outdoor play was 81.8 (SD 57.3) at baseline, 111.4 (SD 90.1) at year 1 follow-up, and 103.6 (SD 76.2) at year 2 follow-up. The mean media min/day at baseline was 83.8 (SD 64.3), 93.7 (SD 80.3) min/day at year 1 follow-up, and 59.9 min/day (SD (45.6) at year 2 follow-up. One additional person per bedroom was associated with 6 fewer min/day with media. The addition of each age appropriate toy was associated with an additional 12.3 min/day of outdoor play. An additional type of inappropriate media was associated with 6.8 more min/day with media. These results suggest changes to the residential environment to improve physical activity among children in Latino farmworker families.

  11. Influence of Selenization Time on Microstructural, Optical, and Electrical Properties of Cu2ZnGeSe4 Films

    NASA Astrophysics Data System (ADS)

    Swapna Mary, G.; Hema Chandra, G.; Anantha Sunil, M.; Gupta, Mukul

    2018-01-01

    We have studied the effects of selenization time on the microstructural, optical, and electrical properties of stacked (Cu/Se/ZnSe/Se/Ge/Se) × 4 layers to demonstrate growth of Cu2ZnGeSe4 (CZGSe) thin films. Electron beam evaporation was used to deposit CZGSe films on glass substrates for selenization in high vacuum at 450°C for different times (15 min, 30 min, 45 min, and 60 min). The incomplete reaction of the precursor layers necessitates selenization at higher temperature for different durations to achieve desirable microstructural and optoelectronic properties. Energy-dispersive spectroscopic measurements revealed that the stacked layers selenized at 450°C for 30 min were nearly stoichiometric with atomic ratios of Cu/(Zn + Ge) = 0.88, Zn/Ge = 1.11, and Se/(Cu + Zn + Ge) = 1.03. X-ray diffraction analysis revealed that the stacks selenized at 450°C for 30 min crystallized in tetragonal stannite structure. Selenization-time-dependent Raman measurements of the selenized stacks are systematically presented to understand the growth of CZGSe. The elemental distribution through depth as a function of selenization time was investigated using secondary-ion mass spectroscopy. The ionic valency of the constituent elements in CZGSe films selenized at 450°C for 30 min was examined using high-resolution x-ray photoelectron spectroscopy. Significant changes were observed in the surface morphology of the stacked layers with increase in selenization time. The effects of defects on the electrical properties and of binary phases on the optical properties are discussed.

  12. Effects of Fentanyl on Emergence Agitation in Children under Sevoflurane Anesthesia: Meta-Analysis of Randomized Controlled Trials

    PubMed Central

    Xiong, Wei; Zhou, Qin; Yang, Peng; Huang, Xiongqing

    2015-01-01

    Background and Objectives The goal of this meta-analysis study was to assess the effects of fentanyl on emergence agitation (EA) under sevoflurane anesthesia in children. Subjects and Methods We searched electronic databases (PubMed, Embase, Web of Science and the Cochrane Central Register of Controlled Trials) for articles published until December 2014. Randomized controlled trials (RCTs) that assessed the effects of fentanyl and placebo on EA under sevoflurane anesthesia in children that the outcome were the incidence of EA, postoperative pain, emergence time or adverse effects were included in this meta-analysis. Results A total of 16 studies, including 1362 patients (737 patients for the fentanyl group and 625 for the placebo group), were evaluated in final analysis. We found that administration of fentanyl decreased the incidences of EA (RR = 0.37, 95% CI 0.27~0.49, P<0.00001) and postoperative pain (RR = 0.59, 95% CI 0.41~0.85, P = 0.004) but increased the incidence of postoperative nausea and vomiting (PONV) (RR = 2.23, 95% CI 1.33~3.77, P = 0.003). The extubation time (WMD = 0.71 min, 95% CI 0.12~1.3, P = 0.02), emergence time (WMD = 4.90 min, 95% CI 2.49~7.30, P<0.0001), and time in the postanesthesia care unit (PACU) (WMD = 2.65 min, 95% CI 0.76~4.53, P = 0.006) were slightly increased. There were no significant differences in the time to discharge of day patients (WMD = 3.72 min, 95% CI -2.80~10.24, P = 0.26). Conclusion Our meta-analysis suggests that fentanyl decreases the incidence of EA under sevoflurane anesthesia in children and postoperative pain, but has a higher incidence of PONV. Considering the inherent limitations of the included studies, more RCTs with extensive follow-up should be performed to validate our findings in the future. PMID:26275039

  13. Genetic diversity and genome-wide association analysis of cooking time in dry bean (Phaseolus vulgaris L.).

    PubMed

    Cichy, Karen A; Wiesinger, Jason A; Mendoza, Fernando A

    2015-08-01

    Fivefold diversity for cooking time found in a panel of 206 Phaseolus vulgaris accessions. Fastest accession cooks nearly 20 min faster than average.   SNPs associated with cooking time on Pv02, 03, and 06. Dry beans (Phaseolus vulgaris L.) are a nutrient dense food and a dietary staple in parts of Africa and Latin America. One of the major factors that limits greater utilization of beans is their long cooking times compared to other foods. Cooking time is an important trait with implications for gender equity, nutritional value of diets, and energy utilization. Very little is known about the genetic diversity and genomic regions involved in determining cooking time. The objective of this research was to assess cooking time on a panel of 206 P. vulgaris accessions, use genome- wide association analysis (GWAS) to identify genomic regions influencing this trait, and to test the ability to predict cooking time by raw seed characteristics. In this study 5.5-fold variation for cooking time was found and five bean accessions were identified which cook in less than 27 min across 2 years, where the average cooking time was 37 min. One accession, ADP0367 cooked nearly 20 min faster than average. Four of these five accessions showed close phylogenetic relationship based on a NJ tree developed with ~5000 SNP markers, suggesting a potentially similar underlying genetic mechanism. GWAS revealed regions on chromosomes Pv02, Pv03, and Pv06 associated with cooking time. Vis/NIR scanning of raw seed explained 68 % of the phenotypic variation for cooking time, suggesting with additional experimentation, it may be possible to use this spectroscopy method to non-destructively identify fast cooking lines as part of a breeding program.

  14. Reduction of the Nailfold Capillary Blood Velocity in Cigarette Smokers

    PubMed Central

    Kim, Kwang-Min; Lee, Duck-Joo

    2012-01-01

    Background Cigarette smoking causes cardiovascular disease and activates markers of endothelial dysfunction or injury. We investigated the nailfold capillary blood velocity (NCV) in cigarette smokers compared to non-smokers. Methods Forty-eight men (eighteen non-smokers and thirty smokers) were recruited. We measured NCV using nailfold capillary microscopy and exhaled carbon monoxide (ECO) concentration three times (before smoking; NCV0min and ECO0min, and after smoking; NCV5min, ECO5min, NCV30min, and ECO30min), in a condition of fasting in the case of smokers. In non-smokers, the same measurements were taken without smoking. Additionally, personal cigarette smoking and alcohol drinking history were acquired by a self-administrated questionnaire. Results Mean age, waist circumference, ECO0min, ECO5min, and ECO30min was higher and NCV5min and NCV30min were significantly lower in smokers compared to non-smokers. Total smoking years were negatively correlated with NCV5min. Average pack of the daily smoking, total pack-years, as well as total smoking years were also negatively correlated with NCV30min by regression analysis. After adjustment of significantly different variables, NCV30min was significantly lower in smokers. In the subgroup analysis, the interleukin-6 level was significantly increased in subjects with a long period of cigarette smoking compared with non-smokers. Conclusion Reduction of NCV in smokers is associated with personal smoking history, not with body composition or certain oxidative stress markers. PMID:23267426

  15. Influence of growth time on crystalline structure, morphologic and optical properties of In2O3 thin films

    NASA Astrophysics Data System (ADS)

    Attaf, A.; Bouhdjar, A.; Saidi, H.; Benkhetta, Y.; Bendjedidi, H.; Nouadji, M.; Lehraki, N.

    2015-03-01

    Indium oxide (In2O3) thin films are successfully deposited on glass substrate at different deposition timings by ultrasonic spray technique using Indium chloride (InCl3) material source witch is prepared with dissolvent Ethanol (C2H5-OH), the physical properties of these films are characterized by XRD, MEB,UV-visible. XRD analysis revealed that the films are polycrystalline in nature having centered cubic crystal structure and symmetry space group I213 with a preferred grain orientation along to (222) plane when the deposition time changes from 4 to 10 min but after t = 10 min, especially when t = 13 min we found that the majority of grains preferred the plane (400). The maximum value of grain size D = 61,51 nm is attained for In2O3 films grown at t =10 min. the average transmittance is about 72%, The optical gap energy is found to decrease from 3.8 to 3.66 eV with growth time Increased from 4 to 10 min but after t = 10 min the value of Eg will increase to 3.72 eV. A systematic study on the influence of growth time on the properties of In2O3 thin films deposited by ultrasonic spray at 400 °C has been reported.

  16. Hyphenation of ultra performance liquid chromatography (UPLC) with inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of bromine containing preservatives.

    PubMed

    Bendahl, Lars; Hansen, Steen Honoré; Gammelgaard, Bente; Sturup, Stefan; Nielsen, Camilla

    2006-02-24

    Ultra performance liquid chromatography (UPLC) was coupled to inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of three bromine-containing preservatives, monitoring the 79Br and 81Br isotopes simultaneously. Due to the efficiency of the 1.7 microm column packing material, the resolution of the test substances was only slightly affected when the linear flow velocity was increased from 0.5 to 1.9 mm s(-1). However, the sensitivity of ICP-MS detection decreased when the linear flow velocity was increased from 0.5 to 1.9 mm s(-1). Analytical figures of merit were determined at an intermediate and at a high linear velocity. The precision was better than 2.2% R.S.D. and regression analysis showed that a linear response was achieved at both flow rates (R2 > 0.9993, n = 36). The analysis time was less than 4.5 min at a flow rate of 50 microL min(-1) and limits of detection and quantification were better than 3.3 and 11 microg BrL(-1), respectively. The analysis time was reduced to 2.7 min when the flow rate was increased to 90 microL min(-1) and limits of detection and quantification were better than 20 and 65 microg BrL(-1), respectively. The method was applied for quantitative analysis of bromine-containing preservatives in commercially available cosmetic products.

  17. A comparative analysis of massed vs. distributed practice on basic math fact fluency growth rates.

    PubMed

    Schutte, Greg M; Duhon, Gary J; Solomon, Benjamin G; Poncy, Brian C; Moore, Kathryn; Story, Bailey

    2015-04-01

    To best remediate academic deficiencies, educators need to not only identify empirically validated interventions but also be able to apply instructional modifications that result in more efficient student learning. The current study compared the effect of massed and distributed practice with an explicit timing intervention to evaluate the extent to which these modifications lead to increased math fact fluency on basic addition problems. Forty-eight third-grade students were placed into one of three groups with each of the groups completing four 1-min math explicit timing procedures each day across 19 days. Group one completed all four 1-min timings consecutively; group two completed two back-to-back 1-min timings in the morning and two back-to-back 1-min timings in the afternoon, and group three completed one, 1-min independent timing four times distributed across the day. Growth curve modeling was used to examine the progress throughout the course of the study. Results suggested that students in the distributed practice conditions, both four times per day and two times per day, showed significantly higher fluency growth rates than those practicing only once per day in a massed format. These results indicate that combining distributed practice with explicit timing procedures is a useful modification that enhances student learning without the addition of extra instructional time when targeting math fact fluency. Copyright © 2015 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  18. The response time threshold for predicting favourable neurological outcomes in patients with bystander-witnessed out-of-hospital cardiac arrest.

    PubMed

    Ono, Yuichi; Hayakawa, Mineji; Iijima, Hiroaki; Maekawa, Kunihiko; Kodate, Akira; Sadamoto, Yoshihiro; Mizugaki, Asumi; Murakami, Hiromoto; Katabami, Kenichi; Sawamura, Atsushi; Gando, Satoshi

    2016-10-01

    It is well established that the period of time between a call being made to emergency medical services (EMS) and the time at which the EMS arrive at the scene (i.e. the response time) affects survival outcomes in patients who experience out-of-hospital cardiac arrest (OHCA). However, the relationship between the response time and favourable neurological outcomes remains unclear. We therefore aimed to determine a response time threshold in patients with bystander-witnessed OHCA that is associated with positive neurological outcomes and to assess the relationship between the response time and neurological outcomes in patients with OHCA. This study was a retrospective, observational analysis of data from 204,277 episodes of bystander-witnessed OHCA between 2006 and 2012 in Japan. We used classification and regression trees (CARTs) and receiver operating characteristic (ROC) curve analyses to determine the threshold of response time associated with favourable neurological outcomes (Cerebral Performance Category 1 or 2) 1 month after cardiac arrest. Both CARTs and ROC analyses indicated that a threshold of 6.5min was associated with improved neurological outcomes in all bystander-witnessed OHCA events of cardiac origin. Furthermore, bystander cardiopulmonary resuscitation (CPR) prolonged the threshold of response time by 1min (up to 7.5min). The adjusted odds ratio for favourable neurological outcomes in patients with OHCA who received care within ≤6.5min was 1.935 (95% confidential interval: 1.834-2.041, P<0.001). A response time of ≤6.5min was closely associated with favourable neurological outcomes in all bystander-witnessed patients with OHCA. Bystander CPR prolonged the response time threshold by 1min. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Daytime Napping and the Risk of Cardiovascular Disease and All-Cause Mortality: A Prospective Study and Dose-Response Meta-Analysis

    PubMed Central

    Yamada, Tomohide; Hara, Kazuo; Shojima, Nobuhiro; Yamauchi, Toshimasa; Kadowaki, Takashi

    2015-01-01

    Study Objectives: To summarize evidence about the association between daytime napping and the risk of cardiovascular disease and all-cause mortality, and to quantify the potential dose-response relation. Design: Meta-analysis of prospective cohort studies. Methods and Results: Electronic databases were searched for articles published up to December 2014 using the terms nap, cardiovascular disease, and all-cause mortality. We selected well-adjusted prospective cohort studies reporting risk estimates for cardiovascular disease and all-cause mortality related to napping. Eleven prospective cohort studies were identified with 151,588 participants (1,625,012 person-years) and a mean follow-up period of 11 years (60% women, 5,276 cardiovascular events, and 18,966 all-cause deaths). Pooled analysis showed that a long daytime nap (≥ 60 min/day) was associated with a higher risk of cardiovascular disease (rate ratio [RR]: 1.82 [1.22–2.71], P = 0.003, I2 = 37%) compared with not napping. All-cause mortality was associated with napping for ≥ 60 min/day (RR: 1.27 [1.11–1.45], P < 0.001, I2 = 0%) compared with not napping. In contrast, napping for < 60 min/day was not associated with cardiovascular disease (P = 0.98) or all-cause mortality (P = 0.08). Meta-analysis demonstrated a significant J-curve dose-response relation between nap time and cardiovascular disease (P for nonlinearity = 0.01). The RR initially decreased from 0 to 30 min/day. Then it increased slightly until about 45 min/day, followed by a sharp increase at longer nap times. There was also a positive linear relation between nap time and all-cause mortality (P for non-linearity = 0.97). Conclusions: Nap time and cardiovascular disease may be associated via a J-curve relation. Further studies are needed to confirm the efficacy of a short nap. Citation: Yamada T, Hara K, Shojima N, Yamauchi T, Kadowaki T. Daytime napping and the risk of cardiovascular disease and all-cause mortality: a prospective study and dose-response meta-analysis. SLEEP 2015;38(12):1945–1953. PMID:26158892

  20. Online time and resource management based on surgical workflow time series analysis.

    PubMed

    Maktabi, M; Neumuth, T

    2017-02-01

    Hospitals' effectiveness and efficiency can be enhanced by automating the resource and time management of the most cost-intensive unit in the hospital: the operating room (OR). The key elements required for the ideal organization of hospital staff and technical resources (such as instruments in the OR) are an exact online forecast of both the surgeon's resource usage and the remaining intervention time. This paper presents a novel online approach relying on time series analysis and the application of a linear time-variant system. We calculated the power spectral density and the spectrogram of surgical perspectives (e.g., used instrument) of interest to compare several surgical workflows. Considering only the use of the surgeon's right hand during an intervention, we were able to predict the remaining intervention time online with an error of 21 min 45 s ±9 min 59 s for lumbar discectomy. Furthermore, the performance of forecasting of technical resource usage in the next 20 min was calculated for a combination of spectral analysis and the application of a linear time-variant system (sensitivity: 74 %; specificity: 75 %) focusing on just the use of surgeon's instrument in question. The outstanding benefit of these methods is that the automated recording of surgical workflows has minimal impact during interventions since the whole set of surgical perspectives need not be recorded. The resulting predictions can help various stakeholders such as OR staff and hospital technicians. Moreover, reducing resource conflicts could well improve patient care.

  1. Relationship Between Reported and Measured Sleep Times

    PubMed Central

    Silva, Graciela E.; Goodwin, James L.; Sherrill, Duane L.; Arnold, Jean L.; Bootzin, Richard R.; Smith, Terry; Walsleben, Joyce A.; Baldwin, Carol M.; Quan, Stuart F.

    2007-01-01

    Study Objective: Subjective and objective assessments of sleep may be discrepant due to sleep misperception and measurement effects, the latter of which may change the quality and quantity of a person's usual sleep. This study compared sleep times from polysomnography (PSG) with self-reports of habitual sleep and sleep estimated on the morning after a PSG in adults. Design: Total sleep time and sleep onset latency obtained from unattended home PSGs were compared to sleep times obtained from a questionnaire completed before the PSG and a Morning Survey completed the morning after the PSG. Participants: A total of 2,113 subjects who were ≥ 40 years of age were included in this analysis. Measures and Results: Subjects were 53% female, 75% Caucasian, and 38% obese. The mean habitual sleep time (HABTST), morning estimated sleep time (AMTST), and PSG total sleep times (PSGTST) were 422 min, 379 min, and 363 min, respectively. The mean habitual sleep onset latency, morning estimated sleep onset latency, and PSG sleep onset latency were 17.0 min, 21.8 min, and 16.9 min, respectively. Models adjusting for related demographic factors showed that HABTST and AMTST differ significantly from PSGTST by 61 and 18 minutes, respectively. Obese and higher educated people reported less sleep time than their counterparts. Similarly, small but significant differences were seen for sleep latency. Conclusions: In a community population, self-reported total sleep times and sleep latencies are overestimated even on the morning following overnight PSG. Citation: Silva GE; Goodwin JL; Sherrill DL; Arnold JL; Bootzin RR; Smith T; Walsleben JA; Baldwin CM; Quan SF. Relationship between reported and measured sleep times: the sleep heart health study (SHHS). J Clin Sleep Med 2007;3(6):622-630. PMID:17993045

  2. Dynamic 3D analysis of myocardial sympathetic innervation: an experimental study using 123I-MIBG and a CZT camera.

    PubMed

    Giorgetti, Assuero; Burchielli, Silvia; Positano, Vincenzo; Kovalski, Gil; Quaranta, Angela; Genovesi, Dario; Tredici, Manuel; Duce, Valerio; Landini, Luigi; Trivella, Maria Giovanna; Marzullo, Paolo

    2015-03-01

    Data on the in vivo myocardial kinetics of (123)I-metaiodobenzylguanidine ((123)I-MIBG) are scarce and have always been obtained using planar acquisitions. To clarify the normal kinetics of (123)I-MIBG in vivo over time, we designed an experimental protocol using a 3-dimensional (3D) dynamic approach with a cadmium zinc telluride (CZT) camera. We studied 6 anesthetized pigs (mean body weight, 37 ± 4 kg). Left ventricular myocardial perfusion and sympathetic innervation were assessed using (99m)Tc-tetrofosmin (26 ± 6 MBq), (123)I-MIBG (54 ± 14 MBq), and a CZT camera. A normal perfusion/function match on gated SPECT was the inclusion criterion. A dynamic acquisition in list mode started simultaneously with the bolus injection of (123)I-MIBG, and data were collected every 5 min for the first 20 min and then at acquisition steps of 30, 60, 90, and 120 min. Each step was reconstructed using dedicate software and reframed (60 s/frame). On the reconstructed transaxial slice that best showed the left ventricular cavity, regions of interest were drawn to obtain myocardial and blood pool activities. Myocardial time-activity curves were generated by interpolating data between contiguous acquisition steps, corrected for radiotracer decay and injected dose, and fitted to a bicompartmental model. Time to myocardial maximum signal intensity (MSI), MSI value, radiotracer retention index (RI, myocardial activity/blood pool integral), and washout rate were calculated. The mediastinal signal was measured and fitted to a linear model. The myocardial MSI of (123)I-MIBG was reached within 5.57 ± 4.23 min (range, 2-12 min). The mean MSI was 0.426% ± 0.092%. Myocardial RI decreased over time and reached point zero at 176 ± 31 min (range, 140-229 min). The ratio between myocardial and mediastinal signal at 15 and 125 min and extrapolated at 176 and 4 h was 5.45% ± 0.61%, 4.33% ± 1.23% (not statistically significant vs. 15 min), 3.95% ± 1.46% (P < 0.03 vs. 125 min), and 3.63% ± 1.64% (P < 0.03 vs. 176 min), respectively. Mean global washout rate at 125 min was 15% ± 14% (range, 0%-34%), and extrapolated data at 176 min and 4 h were 18% ± 18% (range, 0.49%-45%) and 25% ± 23% (range, 1.7%-56.2%; not statistically significant vs. 176 min), respectively. 3D dynamic analysis of (123)I-MIBG suggests that myocardial peak uptake is reached more quickly than previously described. Myocardial RI decreases over time and, on average, is null about 3 h after injection. The combination of an early peak and variations in delayed myocardial uptake could result in a wide physiologic range of washout rates. Mediastinal activity appears to be constant over time and significantly lower than previously described in planar studies, resulting in a higher heart-to-mediastinum ratio. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  3. Numerical analysis of temperature field in the high speed rotary dry-milling process

    NASA Astrophysics Data System (ADS)

    Wu, N. X.; Deng, L. J.; Liao, D. H.

    2018-01-01

    For the effect of the temperature field in the ceramic dry granulation. Based on the Euler-Euler mathematical model, at the same time, made ceramic dry granulation experiment equipment more simplify and established physical model, the temperature of the dry granulation process was simulated with the granulation time. The relationship between the granulation temperature and granulation effect in dry granulation process was analyzed, at the same time, the correctness of numerical simulation was verified by measuring the fluidity index of ceramic bodies. Numerical simulation and experimental results showed that when granulation time was 4min, 5min, 6min, maximum temperature inside the granulation chamber was: 70°C, 85°C, 95°C. And the equilibrium of the temperature in the granulation chamber was weakened, the fluidity index of the billet particles was: 56.4. 89.7. 81.6. Results of the research showed that when granulation time was 5min, the granulation effect was best. When the granulation chamber temperature was more than 85°C, the fluidity index and the effective particles quantity of the billet particles were reduced.

  4. Minimal Window Duration for Accurate HRV Recording in Athletes

    PubMed Central

    Bourdillon, Nicolas; Schmitt, Laurent; Yazdani, Sasan; Vesin, Jean-Marc; Millet, Grégoire P.

    2017-01-01

    Heart rate variability (HRV) is non-invasive and commonly used for monitoring responses to training loads, fitness, or overreaching in athletes. Yet, the recording duration for a series of RR-intervals varies from 1 to 15 min in the literature. The aim of the present work was to assess the minimum record duration to obtain reliable HRV results. RR-intervals from 159 orthostatic tests (7 min supine, SU, followed by 6 min standing, ST) were analyzed. Reference windows were 4 min in SU (min 3–7) and 4 min in ST (min 9–13). Those windows were subsequently divided and the analyses were repeated on eight different fractioned windows: the first min (0–1), the second min (1–2), the third min (2–3), the fourth min (3–4), the first 2 min (0–2), the last 2 min (2–4), the first 3 min (0–3), and the last 3 min (1–4). Correlation and Bland & Altman statistical analyses were systematically performed. The analysis window could be shortened to 0–2 instead of 0–4 for RMSSD only, whereas the 4-min window was necessary for LF and total power. Since there is a need for 1 min of baseline to obtain a steady signal prior the analysis window, we conclude that studies relying on RMSSD may shorten the windows to 3 min (= 1+2) in SU or seated position only and to 6 min (= 1+2 min SU plus 1+2 min ST) if there is an orthostatic test. Studies relying on time- and frequency-domain parameters need a minimum of 5 min (= 1+4) min SU or seated position only but require 10 min (= 1+4 min SU plus 1+4 min ST) for the orthostatic test. PMID:28848382

  5. A scintigraphic analysis of colonic movement in patients with colostomy: changes of colonic transit time after acquaintance with irrigation.

    PubMed

    Yasuda, S; Fujii, H; Yamamoto, K; Nakagawa, M; Watanabe, I; Nakano, H

    1992-01-01

    For the purpose of making a functional assessment of colostomy irrigation, eight patients were examined. Group A was composed of four patients whose experience of irrigation was less than one year. Group B was composed of four patients who had undergone irrigation for more than two years. The capacity of the remnant colon was determined by a barium enema. Next, 74 MBq of milking technetium 99 diethylene triamine penta-acetic acid (99mTc-DTPA) was instilled with a predetermined amount of water (37 degrees C). A dynamic scan was performed for 45 min. The mean evacuation time of Groups A and B were 6 min 56 s +/- 2 min 33 s and 13 min 27 s +/- 10 min 50 s, respectively. The mean half emptying time of Groups A and B were 142.5 s +/- 7.9 s and 309.0 s +/- 181.9 s. The results suggest that the remnant colon may be habituated with irrigation. Colostomy irrigation which uses a single instillation of a measured volume of tepid water is recommended.

  6. Photodegradation of imidacloprid insecticide by Ag-deposited titanate nanotubes: a study of intermediates and their reaction pathways.

    PubMed

    Grover, Inderpreet Singh; Singh, Satnam; Pal, Bonamali

    2014-12-31

    The present work demonstrates the influence of Ag-loading (0.2-1.0 wt %) onto sodium titanate nanotubes (TNT) for complete photomineralization of the neurotoxic imidacloprid (IMI) insecticide under UV light illumination. It has been observed that degradation of IMI follows pseudo-first-order kinetics, where 0.5 wt % Ag-loaded TNT exhibited highest apparent rate constant (2.2 × 10(-2) min(-1)) and corresponding least half-life (t1/2) of 31 min for IMI relative to bare P25-TiO2 (3.4 × 10(-3) min(-1), t1/2 = 230 min). The mineralization of IMI intermediates to CO2 during its photooxidation has been described by time course GC-MS and GC analysis and has been correlated with the kinetic analysis. The investigation for the role and quantitative estimation of the fate of heteroatoms (N, O, and Cl) present in IMI revealed an increase in the amount of nitrate, nitrite, and chloride ions with time during its photooxidation. On the basis of these results a mechanistic pathway for photomineralization of IMI is proposed.

  7. Characteristics analysis of acupuncture electroencephalograph based on mutual information Lempel—Ziv complexity

    NASA Astrophysics Data System (ADS)

    Luo, Xi-Liu; Wang, Jiang; Han, Chun-Xiao; Deng, Bin; Wei, Xi-Le; Bian, Hong-Rui

    2012-02-01

    As a convenient approach to the characterization of cerebral cortex electrical information, electroencephalograph (EEG) has potential clinical application in monitoring the acupuncture effects. In this paper, a method composed of the mutual information method and Lempel—Ziv complexity method (MILZC) is proposed to investigate the effects of acupuncture on the complexity of information exchanges between different brain regions based on EEGs. In the experiments, eight subjects are manually acupunctured at ‘Zusanli’ acupuncture point (ST-36) with different frequencies (i.e., 50, 100, 150, and 200 times/min) and the EEGs are recorded simultaneously. First, MILZC values are compared in general. Then average brain connections are used to quantify the effectiveness of acupuncture under the above four frequencies. Finally, significance index P values are used to study the spatiality of the acupuncture effect on the brain. Three main findings are obtained: (i) MILZC values increase during the acupuncture; (ii) manual acupunctures (MAs) with 100 times/min and 150 times/min are more effective than with 50 times/min and 200 times/min; (iii) contralateral hemisphere activation is more prominent than ipsilateral hemisphere's. All these findings suggest that acupuncture contributes to the increase of brain information exchange complexity and the MILZC method can successfully describe these changes.

  8. Impact of Glucose Measurement Processing Delays on Clinical Accuracy and Relevance

    PubMed Central

    Jangam, Sujit R.; Hayter, Gary; Dunn, Timothy C.

    2013-01-01

    Background In a hospital setting, glucose is often measured from venous blood in the clinical laboratory. However, laboratory glucose measurements are typically not available in real time. In practice, turn-around times for laboratory measurements can be minutes to hours. This analysis assesses the impact of turn-around time on the effective clinical accuracy of laboratory measurements. Methods Data obtained from an earlier study with 58 subjects with type 1 diabetes mellitus (T1DM) were used for this analysis. In the study, glucose measurements using a YSI glucose analyzer were obtained from venous blood samples every 15 min while the subjects were at the health care facility. To simulate delayed laboratory results, each YSI glucose value from a subject was paired with one from a later time point (from the same subject) separated by 15, 30, 45, and 60 min. To assess the clinical accuracy of a delayed YSI result relative to a real-time result, the percentage of YSI pairs that meet the International Organization for Standardization (ISO) 15197:2003(E) standard for glucose measurement accuracy (±15 mg/dl for blood glucose < 75 mg/dl, ±20% for blood glucose ≥ 75 mg/dl) was calculated. Results It was observed that delays of 15 min or more reduce clinical accuracy below the ISO 15197:2003(E) recommendation of 95%. The accuracy was less than 65% for delays of 60 min. Conclusion This analysis suggests that processing delays in glucose measurements reduce the clinical relevance of results in patients with T1DM and may similarly degrade the clinical value of measurements in other patient populations. PMID:23759399

  9. Impact of glucose measurement processing delays on clinical accuracy and relevance.

    PubMed

    Jangam, Sujit R; Hayter, Gary; Dunn, Timothy C

    2013-05-01

    In a hospital setting, glucose is often measured from venous blood in the clinical laboratory. However, laboratory glucose measurements are typically not available in real time. In practice, turn-around times for laboratory measurements can be minutes to hours. This analysis assesses the impact of turn-around time on the effective clinical accuracy of laboratory measurements. Data obtained from an earlier study with 58 subjects with type 1 diabetes mellitus (T1DM) were used for this analysis. In the study, glucose measurements using a YSI glucose analyzer were obtained from venous blood samples every 15 min while the subjects were at the health care facility. To simulate delayed laboratory results, each YSI glucose value from a subject was paired with one from a later time point (from the same subject) separated by 15, 30, 45, and 60 min. To assess the clinical accuracy of a delayed YSI result relative to a real-time result, the percentage of YSI pairs that meet the International Organization for Standardization (ISO) 15197:2003(E) standard for glucose measurement accuracy (±15 mg/dl for blood glucose < 75 mg/dl, ±20% for blood glucose ≥ 75 mg/dl) was calculated. It was observed that delays of 15 min or more reduce clinical accuracy below the ISO 15197:2003(E) recommendation of 95%. The accuracy was less than 65% for delays of 60 min. This analysis suggests that processing delays in glucose measurements reduce the clinical relevance of results in patients with T1DM and may similarly degrade the clinical value of measurements in other patient populations. © 2013 Diabetes Technology Society.

  10. Effect of sugammadex on coagulation as detected by rotational thromboelastometry in morbidly obese patients.

    PubMed

    Carron, Michele; Bertini, Diana; Prandini, Tancredi; Fanton, Francesca; Foletto, Mirto; Ori, Carlo; Perissinotto, Egle; Simioni, Paolo

    2018-02-01

    Sugammadex, which is used to reverse rocuronium-induced neuromuscular blockade, has a limited and transient effect on activated partial thromboplastin time and prothrombin time. However, no data are available on the effects of sugammadex on coagulation in morbidly obese patients, as assessed by rotational thromboelastometry (ROTEM®). Sixty patients received sugammadex 2 mg/kg or 4 mg/kg to reverse moderate or deep rocuronium-induced neuromuscular blockade (N.=30/group) at the end of surgery under desflurane anesthesia. Arterial blood samples were collected before and 3 min and 30 min after sugammadex administration for ROTEM® analysis, including measurements of clotting time (CT), clot formation time, α angle, and maximum clot firmness in INTEM, EXTEM, and FIBTEM assays. Major and minor bleeding events were also monitored during the postoperative period. Sugammadex 2 and 4 mg/kg has a limited and transient (<30 min) effect on INTEM CTs of 7.7% (P=0.04) and 10.7% (P<0.0001), respectively. There were no relevant effects on other ROTEM® parameters. A multivariate analysis indicated a significant effect of total sugammadex dose (<250, 250-500, >500 mg) on the INTEM CT (P=0.002). A regression analysis showed a positive relationship between sugammadex dose and INTEM CT value at 3 min after administration (coefficient = 0.052 s; 95% CI: 0.005-0.098 s; P=0.03). No major or minor bleeding events were observed in either group during the postoperative period. Sugammadex produces a slight effect on coagulation in morbidly obese patients, without increasing the risk for postoperative bleeding.

  11. Prospective analysis of time out-of-home and objectively measured walking duration during a week in a large cohort of older adults.

    PubMed

    Rapp, Kilian; Mikolaizak, Stefanie; Rothenbacher, Dietrich; Denkinger, Michael D; Klenk, Jochen

    2018-01-01

    Physical activity is considered an effective measure to promote health in older people. There is evidence that the number of outdoor trips increases physical activity by increasing walking duration. The objective of this study was to analyse the relationship between daily time out-of-home and walking duration. Furthermore, predictors for walking duration and time out-of-home were evaluated. Walking duration was measured prospectively over a 1 week period by a body-fixed sensor and the time out-of-home was assessed by a questionnaire at the same days. Seven thousand, two hundred and forty-three days from 1289 older people (mean age 75.4 years) with both sensor-based measures and completed questionnaires were included in the analyses. To account for several observation days per participant multilevel regression analyses were applied. Analyses were stratified according to the time out-of-home (more or less than 100 min/day). In the group with less than 100 min out-of-home, each additional minute out-of-home added 20 s to overall walking duration. If the time exceeded 100 min the additional increase of walking duration was only moderate or weak. Leaving the home once added 40 min of walking, the following trips 15 to 20 min. Increasing age, lower gait speed, comorbidities, low temperature, rain and specific week days (Sunday) decreased both the time out-of-home and walking duration. Other variables like gender (female), isolation or living with a spouse reduced the time out-of-home without affecting walking duration. Being out-of-home increases daily walking duration. The association is strongest if the time out-of-home is 100 min or less.

  12. SU-F-T-266: Dynalogs Based Evaluation of Different Dose Rate IMRT Using DVH and Gamma Index

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmed, S; Ahmed, S; Ahmed, F

    2016-06-15

    Purpose: This work investigates the impact of low and high dose rate on IMRT through Dynalogs by evaluating Gamma Index and Dose Volume Histogram. Methods: The Eclipse™ treatment planning software was used to generate plans on prostate and head and neck sites. A range of dose rates 300 MU/min and 600 MU/min were applied to each plan in order to investigate their effect on the beam ON time, efficiency and accuracy. Each plan had distinct monitor units per fraction, delivery time, mean dose rate and leaf speed. The DVH data was used in the assessment of the conformity and planmore » quality.The treatments were delivered on Varian™ Clinac 2100C accelerator equipped with 120 leaf millennium MLC. Dynalogs of each plan were analyzed by MATLAB™ program. Fluence measurements were performed using the Sun Nuclear™ 2D diode array and results were assessed, based on Gamma analysis of dose fluence maps, beam delivery statistics and Dynalogs data. Results: Minor differences found by adjusted R-squared analysis of DVH’s for all the plans with different dose rates. It has been also found that more and larger fields have greater time reduction at high dose rate and there was a sharp decrease in number of control points observed in dynalog files by switching dose rate from 300 MU/min to 600 MU/min. Gamma Analysis of all plans passes the confidence limit of ≥95% with greater number of passing points in 300 MU/min dose rate plans. Conclusion: The dynalog files are compatible tool for software based IMRT QA. It can work perfectly parallel to measurement based QA setup and stand-by procedure for pre and post delivery of treatment plan.« less

  13. Novel Index (Hepatic Receptor: IHR) to Evaluate Hepatic Functional Reserve Using (99m)Tc-GSA Scintigraphy.

    PubMed

    Hasegawa, Daisuke; Onishi, Hideo; Matsutomo, Norikazu

    2016-02-01

    This study aimed to evaluate the novel index of hepatic receptor (IHR) on the regression analysis derived from time activity curve of the liver for hepatic functional reserve. Sixty patients had undergone (99m)Tc-galactosyl serum albumin ((99m)Tc-GSA) scintigraphy in the retrospective clinical study. Time activity curves for liver were obtained by region of interest (ROI) on the whole liver. A novel hepatic functional predictor was calculated with multiple regression analysis of time activity curves. In the multiple regression function, the objective variables were the indocyanine green (ICG) retention rate at 15 min, and the explanatory variables were the liver counts in 3-min intervals until end from beginning. Then, this result was defined by IHR, and we analyzed the correlation between IHR and ICG, uptake ratio of the heart at 15 minutes to that at 3 minutes (HH15), uptake ratio of the liver to the liver plus heart at 15 minutes (LHL15), and index of convexity (IOC). Regression function of IHR was derived as follows: IHR=0.025×L(6)-0.052×L(12)+0.027×L(27). The multiple regression analysis indicated that liver counts at 6 min, 12 min, and 27 min were significantly related to objective variables. The correlation coefficient between IHR and ICG was 0.774, and the correlation coefficient between ICG and conventional indices (HH15, LHL15, and IOC) were 0.837, 0.773, and 0.793, respectively. IHR had good correlation with HH15, LHL15, and IOC. The finding results suggested that IHR would provide clinical benefit for hepatic functional assessment in the (99m)Tc-GSA scintigraphy.

  14. Validation of an ultrasound dilution technology for cardiac output measurement and shunt detection in infants and children.

    PubMed

    Lindberg, Lars; Johansson, Sune; Perez-de-Sa, Valeria

    2014-02-01

    To validate cardiac output measurements by ultrasound dilution technology (COstatus monitor) against those obtained by a transit-time ultrasound technology with a perivascular flow probe and to investigate ultrasound dilution ability to estimate pulmonary to systemic blood flow ratio in children. Prospective observational clinical trial. Pediatric cardiac operating theater in a university hospital. In 21 children (6.1 ± 2.6 kg, mean ± SD) undergoing heart surgery, cardiac output was simultaneously recorded by ultrasound dilution (extracorporeal arteriovenous loop connected to existing arterial and central venous catheters) and a transit-time ultrasound probe applied to the ascending aorta, and when possible, the main pulmonary artery. The pulmonary to systemic blood flow ratio estimated from ultrasound dilution curve analysis was compared with that estimated from transit-time ultrasound technology. Bland-Altman analysis of the whole cohort (90 pairs, before and after surgery) showed a bias between transit-time ultrasound (1.01 ± 0.47 L/min) and ultrasound dilution technology (1.03 ± 0.51 L/min) of -0.02 L/min, limits of agreement -0.3 to 0.3 L/min, and percentage error of 31%. In children with no residual shunts, the bias was -0.04 L/min, limits of agreement -0.28 to 0.2 L/min, and percentage error 19%. The pooled co efficient of variation was for the whole cohort 3.5% (transit-time ultrasound) and 6.3% (ultrasound dilution), and in children without shunt, it was 2.9% (transit-time ultrasound) and 4% (ultrasound dilution), respectively. Ultrasound dilution identified the presence of shunts (pulmonary to systemic blood flow ≠ 1) with a sensitivity of 100% and a specificity of 92%. Mean pulmonary to systemic blood flow ratio by transit-time ultrasound was 2.6 ± 1.0 and by ultrasound dilution 2.2 ± 0.7 (not significant). The COstatus monitor is a reliable technique to measure cardiac output in children with high sensitivity and specificity for detecting the presence of shunts.

  15. Lack of sensitivity of staffing for 8-hour sessions to standard deviation in daily actual hours of operating room time used for surgeons with long queues.

    PubMed

    Pandit, Jaideep J; Dexter, Franklin

    2009-06-01

    At multiple facilities including some in the United Kingdom's National Health Service, the following are features of many surgical-anesthetic teams: i) there is sufficient workload for each operating room (OR) list to almost always be fully scheduled; ii) the workdays are organized such that a single surgeon is assigned to each block of time (usually 8 h); iii) one team is assigned per block; and iv) hardly ever would a team "split" to do cases in more than one OR simultaneously. We used Monte-Carlo simulation using normal and Weibull distributions to estimate the times to complete lists of cases scheduled into such 8 h sessions. For each combination of mean and standard deviation, inefficiencies of use of OR time were determined for 10 h versus 8 h of staffing. When the mean actual hours of OR time used averages < or = 8 h 25 min, 8 h of staffing has higher OR efficiency than 10 h for all combinations of standard deviation and relative cost of over-run to under-run. When mean > or = 8 h 50 min, 10 h staffing has higher OR efficiency. For 8 h 25 min < mean < 8 h 50 min, the economic break-even point depends on conditions. For example, break-even is: (a) 8 h 27 min for Weibull, standard deviation of 60 min and relative cost of over-run to under-run of 2.0 versus (b) 8 h 48 min for normal, standard deviation of 0 min and relative cost ratio of 1.50. Although the simplest decision rule would be to staff for 8 h if the mean workload is < or = 8 h 40 min and to staff for 10 h otherwise, performance was poor. For example, for the Weibull distribution with mean 8 h 40 min, standard deviation 60 min, and relative cost ratio of 2.00, the inefficiency of use of OR time would be 34% larger if staffing were planned for 8 h instead of 10 h. For surgical teams with 8 h sessions, use the following decision rule for anesthesiology and OR nurse staffing. If actual hours of OR time used averages < or = 8 h 25 min, plan 8 h staffing. If average > or = 8 h 50 min, plan 10 h staffing. For averages in between, perform the full analysis of McIntosh et al. (Anesth Analg 2006;103:1499-516).

  16. Optimization of torrefaction conditions of coffee industry residues using desirability function approach.

    PubMed

    Buratti, C; Barbanera, M; Lascaro, E; Cotana, F

    2018-03-01

    The aim of the present study is to analyze the influence of independent process variables such as temperature, residence time, and heating rate on the torrefaction process of coffee chaff (CC) and spent coffee grounds (SCGs). Response surface methodology and a three-factor and three-level Box-Behnken design were used in order to evaluate the effects of the process variables on the weight loss (W L ) and the Higher Heating Value (HHV) of the torrefied materials. Results showed that the effects of the three factors on both responses were sequenced as follows: temperature>residence time>heating rate. Data obtained from the experiments were analyzed by analysis of variance (ANOVA) and fitted to second-order polynomial models by using multiple regression analysis. Predictive models were determined, able to obtain satisfactory fittings of the experimental data, with coefficient of determination (R 2 ) values higher than 0.95. An optimization study using Derringer's desired function methodology was also carried out and the optimal torrefaction conditions were found: temperature 271.7°C, residence time 20min, heating rate 5°C/min for CC and 256.0°C, 20min, 25°C/min for SCGs. The experimental values closely agree with the corresponding predicted values. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Using the MDCT thick slab MinIP method for the follow-up of pulmonary emphysema.

    PubMed

    Lan, Hai; Nishitani, Hiromu; Nishihara, Sadamitsu; Ueno, Junji; Takao, Shoichiro; Iwamoto, Seiji; Kawanaka, Takashi; Mahmut, Mawlan; Qingge, Si

    2011-08-01

    The purpose of this study was to evaluate the usefulness of thick slab minimum intensity projection (MinIP) as a follow-up method in patients with pulmonary emphysema. This method was used to determine the presence or absence of changes over time in the lung field based on multi-detector-row CT (MDCT) data. Among patients diagnosed with pulmonary emphysema who underwent 16-MDCT (slice thickness, 1 mm) twice at an interval of 6 months or more, 12 patients without changes in the lung field and 14 with clear changes in the lung field were selected as subjects. An image interpretation experiment was performed by five image interpreters. Pulmonary emphysema was followed up using two types of thick slab MinIP (thick slab MinIP 1 and 2) and multi-planar reformation (MPR), and the results of image interpretation were evaluated by receiver operating characteristic (ROC) analysis. In addition, the time required for image interpretation was compared among the three follow-up methods. The area under the ROC curve (Az) was 0.794 for thick slab MinIP 1, 0.778 for the thick slab MinIP 2, and 0.759 for MPR, showing no significant differences among the three methods. Individual differences in each item were significantly more marked for MPR than for thick slab MinIP. The time required for image interpretation was around 18 seconds for thick slab MinIP 1, 11 seconds for thick slab MinIP 2, and approximately 127 seconds for MPR, showing significant differences among the three methods. There were no significant differences in the results of image interpretation regarding the presence or absence of changes in the lung fields between thick slab MinIP and MPR. However, thick slab MinIP showed a shorter image interpretation time and smaller individual differences in the results among image interpreters than MPR, suggesting the usefulness of this method for determining the presence or absence of changes with time in the lung fields of patients with pulmonary emphysema.

  18. Effects of Whey, Caseinate, or Milk Protein Ingestion on Muscle Protein Synthesis after Exercise

    PubMed Central

    Kanda, Atsushi; Nakayama, Kyosuke; Sanbongi, Chiaki; Nagata, Masashi; Ikegami, Shuji; Itoh, Hiroyuki

    2016-01-01

    Whey protein (WP) is characterized as a “fast” protein and caseinate (CA) as a “slow” protein according to their digestion and absorption rates. We hypothesized that co-ingestion of milk proteins (WP and CA) may be effective for prolonging the muscle protein synthesis response compared to either protein alone. We therefore compared the effect of ingesting milk protein (MP) to either WP or CA alone on muscle protein synthesis after exercise in rats. We also compared the effects of these milk-derived proteins to a control, soy protein (SP). Male Sprague-Dawley rats swam for two hours. Immediately after exercise, one of the following four solutions was administered: WP, CA, MP, or SP. Individual rats were euthanized at designated postprandial time points and triceps muscle samples collected for measurement of the protein fractional synthesis rate (FSR). FSR tended to increase in all groups post-ingestion, although the initial peaks of FSR occurred at different times (WP, peak time = 60 min, FSR = 7.76%/day; MP, peak time = 90 min, FSR = 8.34%/day; CA, peak time = 120 min, FSR = 7.85%/day). Milk-derived proteins caused significantly greater increases (p < 0.05) in FSR compared with SP at different times (WP, 60 min; MP, 90 and 120 min; CA, 120 min). Although statistical analysis could not be performed, the calculated the area under the curve (AUC) values for FSR following this trend were: MP, 534.61; CA, 498.22; WP, 473.46; and SP, 406.18. We conclude that ingestion of MP, CA or WP causes the initial peak time in muscle protein synthesis to occur at different times (WP, fast; MP, intermediate; CA, slow) and the dairy proteins have a superior effect on muscle protein synthesis after exercise compared with SP. PMID:27271661

  19. Effects of Whey, Caseinate, or Milk Protein Ingestion on Muscle Protein Synthesis after Exercise.

    PubMed

    Kanda, Atsushi; Nakayama, Kyosuke; Sanbongi, Chiaki; Nagata, Masashi; Ikegami, Shuji; Itoh, Hiroyuki

    2016-06-03

    Whey protein (WP) is characterized as a "fast" protein and caseinate (CA) as a "slow" protein according to their digestion and absorption rates. We hypothesized that co-ingestion of milk proteins (WP and CA) may be effective for prolonging the muscle protein synthesis response compared to either protein alone. We therefore compared the effect of ingesting milk protein (MP) to either WP or CA alone on muscle protein synthesis after exercise in rats. We also compared the effects of these milk-derived proteins to a control, soy protein (SP). Male Sprague-Dawley rats swam for two hours. Immediately after exercise, one of the following four solutions was administered: WP, CA, MP, or SP. Individual rats were euthanized at designated postprandial time points and triceps muscle samples collected for measurement of the protein fractional synthesis rate (FSR). FSR tended to increase in all groups post-ingestion, although the initial peaks of FSR occurred at different times (WP, peak time = 60 min, FSR = 7.76%/day; MP, peak time = 90 min, FSR = 8.34%/day; CA, peak time = 120 min, FSR = 7.85%/day). Milk-derived proteins caused significantly greater increases (p < 0.05) in FSR compared with SP at different times (WP, 60 min; MP, 90 and 120 min; CA, 120 min). Although statistical analysis could not be performed, the calculated the area under the curve (AUC) values for FSR following this trend were: MP, 534.61; CA, 498.22; WP, 473.46; and SP, 406.18. We conclude that ingestion of MP, CA or WP causes the initial peak time in muscle protein synthesis to occur at different times (WP, fast; MP, intermediate; CA, slow) and the dairy proteins have a superior effect on muscle protein synthesis after exercise compared with SP.

  20. Randomised controlled non-inferiority trial of primary care-based facilitated access to an alcohol reduction website: cost-effectiveness analysis

    PubMed Central

    Wallace, Paul; Struzzo, Pierluigi; Vedova, Roberto Della; Scafuri, Francesca; Tersar, Costanza; Lygidakis, Charilaos; McGregor, Richard; Scafato, Emanuele; Freemantle, Nick

    2017-01-01

    Objectives To evaluate the 12-month costs and quality-adjusted life years (QALYs) gained to the Italian National Health Service of facilitated access to a website for hazardous drinkers compared with a standard face-to-face brief intervention (BI). Design Randomised 1:1 non-inferiority trial. Setting Practices of 58 general practitioners (GPs) in Italy. Participants Of 9080 patients (>18 years old) approached to take part in the trial, 4529 (49·9%) logged on to the website and 3841 (84.8%) undertook online screening for hazardous drinking. 822 (21.4%) screened positive and 763 (19.9%) were recruited to the trial. Interventions Patients were randomised to receive either a face-to-face BI or access via a brochure from their GP to an alcohol reduction website (facilitated access). Primary and secondary outcome measures The primary outcome is the cost per QALY gained of facilitated access compared with face-to-face. A secondary analysis includes total costs and benefits per 100 patients, including number of hazardous drinkers prevented at 12 months. Results The average time required for the face-to-face BI was 8 min (95% CI 7.5 min to 8.6 min). Given the maximum time taken for facilitated access of 5 min, face-to-face is an additional 3 min: equivalent to having time for another GP appointment for every three patients referred to the website. Complete case analysis adjusting for baseline the difference in QALYs for facilitated access is 0.002 QALYs per patient (95% CI −0.007 to 0.011). Conclusions Facilitated access to a website to reduce hazardous drinking costs less than a face-to-face BI given by a GP with no worse outcomes. The lower cost of facilitated access, particularly in regards to investment of time, may facilitate the increase in provision of BIs for hazardous drinking. Trial registration number NCT01638338;Post-results. PMID:29102983

  1. Field Analysis of Polychlorinated Biphenyls (PCBs) in Soil Using Solid-Phase Microextraction (SPME) and a Portable Gas Chromatography-Mass Spectrometry System.

    PubMed

    Zhang, Mengliang; Kruse, Natalie A; Bowman, Jennifer R; Jackson, Glen P

    2016-05-01

    An expedited field analysis method was developed for the determination of polychlorinated biphenyls (PCBs) in soil matrices using a portable gas chromatography-mass spectrometry (GC-MS) instrument. Soil samples of approximately 0.5 g were measured with a portable scale and PCBs were extracted by headspace solid-phase microextraction (SPME) with a 100 µm polydimethylsiloxane (PDMS) fiber. Two milliliters of 0.2 M potassium permanganate and 0.5 mL of 6 M sulfuric acid solution were added to the soil matrices to facilitate the extraction of PCBs. The extraction was performed for 30 min at 100 ℃ in a portable heating block that was powered by a portable generator. The portable GC-MS instrument took less than 6 min per analysis and ran off an internal battery and helium cylinder. Six commercial PCB mixtures, Aroclor 1016, 1221, 1232, 1242, 1248, 1254, and 1260, could be classified based on the GC chromatograms and mass spectra. The detection limit of this method for Aroclor 1260 in soil matrices is approximately 10 ppm, which is sufficient for guiding remediation efforts in contaminated sites. This method was applicable to the on-site analysis of PCBs with a total analysis time of 37 min per sample. However, the total analysis time could be improved to less than 7 min per sample by conducting the rate-limiting extraction step for different samples in parallel. © The Author(s) 2016.

  2. A dryer for rapid response on-line expired gas measurements.

    PubMed

    Deno, N S; Kamon, E

    1979-06-01

    A dryer is described for use in on-line breath-by-breath gas analysis systems. The dryer continuously removes water vapor by condensation and controls the sample gas at 2 degrees C dew-point temperature or 5 Torr water vapor partial pressure. It is designed to operate at gas sampling flow rates from 0.5 to 1 1.min-1. The step-response time for the described system including a Beckman LB-2 CO2 analyzer, sampling tubing, and dryer is 120 ms at 1 l.min-1. The time required for gas samples to transport through the dryer is 105 ms at a gas sampling-flow rate of 1 l.min=1.

  3. Effect of cooking time on some nutrient and antinutrient components of bambaragroundnut seeds.

    PubMed

    Omoikhoje, Stanley Omoh; Aruna, Mohammed Bashiru; Bamgbose, Adeyemi Mustapha

    2009-02-01

    The proximate composition, gross energy, mineral composition, percentage sugar, oligosaccharides and antinutrient substances of bambaragroundnut seeds subjected to different cooking times were determined. The seeds were cooked for 30, 60, 90 and 120 min. Results of the proximate analysis showed that only the ether extract and ash were significantly (P < 0.05) reduced as the cooking time increased. In contrast, gross energy values significantly (P < 0.05) increased with increased cooking time. Amongst, the mineral elements assayed, calcium, magnesium and iron were significantly (P < 0.05) increased, while phosphorous, potassium, sodium and copper were reduced significantly (P > 0.05) with inreased cooking time. Percentage sucrose and glucose of bambaragroundnut seeds were significantly (P < 0.05) lowest in the raw form, but increased progressively with increased of cooking time. Raffinose and stachyose levels were reduced significantly by increased cookinf time (P < 0.05) with the least value in seeds cooked for 120 min. Trypsin inhibitor, hemagglutinin and tannin were completely eliminated in seeds cooked for 60 min or longer, but the phytin level was reduced significantly (P < 0.05) by cooking. For a significant detoxification of antinutrient substances and for optimal bioavailability of the component nutrients of bambaragroundnut seeds, an optimum cooking time of 60 min at 100 degrees C is therefore recommended.

  4. Procedures in the 13C octanoic acid breath test for measurement of gastric emptying: analysis using Bland-Altman methods.

    PubMed

    Clegg, Miriam E; Shafat, Amir

    2010-08-01

    The (13)C octanoic acid breath test (OBT) was first developed as an alternative method of measuring gastric emptying (GE) to scintigraphy. There has been much debate about the test duration and how often measurements need to be taken. This study aims to address these issues. For 78 GE tests using the (13)C OBT, GE lag phase (T(lag)) was calculated while sampling more frequently than the recommended every 15 min. Comparisons between T(lag) were completed using Bland-Altman plots. Similarly, 4 or 6 h test durations were assessed to establish if they yield the same GE half time (T(half)). From one volunteer, samples were taken every 1 min for the first 30 min and then every 15 min until 6 h. GE times were then calculated using different combinations of sampling times. Evidence of a visible T(lag) was also explored from this data. Findings indicated that taking samples every 5 min for the first 30 min instead of every 15 min did not change the GE T(lag) based on Bland-Altman plots. The correlation between these two methods was also high (r(2) = 0.9957). The findings showed that the difference between the two sampling durations 4 and 6 h was large and the correlation between the methods was low (r(2) = 0.8335). Samples taken at a rate of one breath per min indicated lack of a visible T(lag). Sampling for the (13)C OBT should be completed every 15 min for 6 h.

  5. Hydrolysis of bamboo biomass by subcritical water treatment.

    PubMed

    Mohan, Mood; Banerjee, Tamal; Goud, Vaibhav V

    2015-09-01

    The aim of present study was to obtain total reducing sugars (TRS) from bamboo under subcritical water (SCW) treatment in a batch reactor at the temperature ranging from 170 °C to 220 °C and 40 min hydrolysis time. Experiments were performed to investigate the effects of temperature and time on TRS yield. The maximum TRS yield (42.21%) was obtained at lower temperature (180 °C), however longer reaction time (25 min). X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopy, and scanning electron microscopy (SEM) analysis were used to characterise treated and untreated bamboo samples. The XRD profile revealed that crystallinity of bamboo increased to 71.90% with increase in temperature up to 210 °C and decreased thereafter to 70.92%. The first-order reaction kinetic model was used to fit the experimental data to obtain rate constants. From the Arrhenius plot, activation energy and pre-exponential factor at 25 min time were found to be 17.97 kJ mol(-1) and 0.154 min(-1), respectively. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. The SmartOR: a distributed sensor network to improve operating room efficiency.

    PubMed

    Huang, Albert Y; Joerger, Guillaume; Fikfak, Vid; Salmon, Remi; Dunkin, Brian J; Bass, Barbara L; Garbey, Marc

    2017-09-01

    Despite the significant expense of OR time, best practice achieves only 70% efficiency. Compounding this problem is a lack of real-time data. Most current OR utilization programs require manual data entry. Automated systems require installation and maintenance of expensive tracking hardware throughout the institution. This study developed an inexpensive, automated OR utilization system and analyzed data from multiple operating rooms. OR activity was deconstructed into four room states. A sensor network was then developed to automatically capture these states using only three sensors, a local wireless network, and a data capture computer. Two systems were then installed into two ORs, recordings captured 24/7. The SmartOR recorded the following events: any room activity, patient entry/exit time, anesthesia time, laparoscopy time, room turnover time, and time of preoperative patient identification by the surgeon. From November 2014 to December 2015, data on 1003 cases were collected. The mean turnover time was 36 min, and 38% of cases met the institutional goal of ≤30 min. Data analysis also identified outlier cases (>1 SD from mean) in the domains of time from patient entry into the OR to intubation (11% of cases) and time from extubation to patient exiting the OR (11% of cases). Time from surgeon identification of patient to scheduled procedure start time was 11 min (institution bylaws require 20 min before scheduled start time), yet OR teams required 22 min on average to bring a patient into the room after surgeon identification. The SmartOR automatically and reliably captures data on OR room state and, in real time, identifies outlier cases that may be examined closer to improve efficiency. As no manual entry is required, the data are indisputable and allow OR teams to maintain a patient-centric focus.

  7. Anterolateral minithoracotomy versus median sternotomy for the treatment of congenital heart defects: a meta-analysis and systematic review

    PubMed Central

    2012-01-01

    Background Anterolateral Minithoracotomy (ALMT) for the radical correction of Congenital Heart Defects is an alternative to Median Sternotomy (MS) due to reduce operative trauma accelerating recovery and yield a better cosmetic outcome after surgery. Our purpose is to conduct whether ALMT would bring more short-term benefits to patients than conventional Median Sternotomy by using a meta-analysis of case–control study in the published English Journal. Methods 6 case control studies published in English from 1997 to 2011 were identified and synthesized to compare the short-term postoperative outcomes between ALMT and MS. These outcomes were cardiopulmonary bypass time, aortic cross-clamp time, intubation time, intensive care unit stay time, and postoperative hospital stay time. Results ALMT had significantly longer cardiopulmonary bypass times (8.00 min more, 95% CI 0.36 to 15.64 min, p = 0.04). Some evidence proved that aortic cross-clamp time of ALMT was longer, yet not significantly (2.38 min more, 95% CI −0.15 to 4.91 min, p = 0.06). In addition, ALMT had significantly shorter intubation time (1.66 hrs less, 95% CI −3.05 to −0.27 hrs, p = 0.02). Postoperative hospital stay time was significantly shorter with ALMT (1.52 days less, 95% CI −2.71 to −0.33 days, p = 0.01). Some evidence suggested a reduction in ICU stay time in the ALMT group. However, this did not prove to be statistically significant (0.88 days less, 95% CI −0.81 to 0.04 days, p = 0.08). Conclusion ALMT can bring more benefits to patients with Congenital Heart Defects by reducing intubation time and postoperative hospital stay time, though ALMT has longer CPB time and aortic cross-clamp time. PMID:22559820

  8. Accurate computer-aided quantification of left ventricular parameters: experience in 1555 cardiac magnetic resonance studies from the Framingham Heart Study.

    PubMed

    Hautvast, Gilion L T F; Salton, Carol J; Chuang, Michael L; Breeuwer, Marcel; O'Donnell, Christopher J; Manning, Warren J

    2012-05-01

    Quantitative analysis of short-axis functional cardiac magnetic resonance images can be performed using automatic contour detection methods. The resulting myocardial contours must be reviewed and possibly corrected, which can be time-consuming, particularly when performed across all cardiac phases. We quantified the impact of manual contour corrections on both analysis time and quantitative measurements obtained from left ventricular short-axis cine images acquired from 1555 participants of the Framingham Heart Study Offspring cohort using computer-aided contour detection methods. The total analysis time for a single case was 7.6 ± 1.7 min for an average of 221 ± 36 myocardial contours per participant. This included 4.8 ± 1.6 min for manual contour correction of 2% of all automatically detected endocardial contours and 8% of all automatically detected epicardial contours. However, the impact of these corrections on global left ventricular parameters was limited, introducing differences of 0.4 ± 4.1 mL for end-diastolic volume, -0.3 ± 2.9 mL for end-systolic volume, 0.7 ± 3.1 mL for stroke volume, and 0.3 ± 1.8% for ejection fraction. We conclude that left ventricular functional parameters can be obtained under 5 min from short-axis functional cardiac magnetic resonance images using automatic contour detection methods. Manual correction more than doubles analysis time, with minimal impact on left ventricular volumes and ejection fraction. Copyright © 2011 Wiley Periodicals, Inc.

  9. Suitability of feeding and chewing time for estimation of feed intake in dairy cows.

    PubMed

    Pahl, C; Hartung, E; Grothmann, A; Mahlkow-Nerge, K; Haeussermann, A

    2016-09-01

    Monitoring of feeding and rumination behaviour can provide useful information for dairy herd management. The feeding behaviour of dairy cows can be recorded by different techniques, such as video cameras, weighing troughs or chewing sensors. Among feeding characteristics, individual feed intake of cows is of utmost interest, but as weighing troughs have high space and cost requirements they are used primarily in research studies. The objective of the present study was to evaluate whether records on feeding time or chewing activity or a combination of both contain enough information to estimate feed intake with sufficient accuracy. Feed intake and feeding time per cow were recorded by means of weighing troughs. Concurrently, chewing activity of seven cows was recorded by MSR-ART pressure sensors during five to eight measuring days per cow. Feeding and chewing behaviour were evaluated in time slots (1 min) and additionally assigned to feeding bouts for further analysis. The 1 min time slots were classified into feeding/no feeding or chewing/no chewing by the two systems, and agreement was found in 92.2% of the records. On average, cows spent 270±39 min/day at the feeding troughs and chewed 262±48 min/day. The average fresh matter intake (FMI) was 49.6±5.1 kg/day. Feed intake was divided into 9.7 bouts/day during which cows fed in average 27.8±21.7 min/bout and chewed 27.0±23.1 min/bout. The correlation between FMI and feeding time was r=0.891 and between FMI and chewing time r=0.780 overall cows. Hence, both systems delivered suitable information for estimating feed intake.

  10. Impact of varying analytical methodologies on grain particle size determination.

    PubMed

    Kalivoda, J R; Jones, C K; Stark, C R

    2017-01-01

    The determination of particle size is an important quality control measurement for feed manufacturers, nutritionists, and producers. The current approved method for determining the geometric mean diameter by weight (d) and geometric standard deviation (S) of grains is standard ANSI/ASAE S319.4. This method controls many variables, including the suggested quantity of initial material and the type, number, and size of sieves. However, the method allows for variations in sieving time, sieve agitators, and the use of a dispersion agent. The objective of this experiment was to determine which method of particle size analysis best estimated the particle size of various cereal grain types. Eighteen samples of either corn, sorghum, or wheat were ground and analyzed using different variations of the approved method. Treatments were arranged in a 5 × 3 factorial arrangement with 5 sieving methods: 1) 10-min sieving time with sieve agitators and no dispersion agent, 2) 10-min sieving time with sieve agitators and dispersion agent, 3) 15-min sieving time with no sieve agitators or dispersion agent, 4) 15-min sieving time with sieve agitators and no dispersion agent, and 5) 15-min sieving time with sieve agitators and dispersion agent conducted in 3 grain types (ground corn, sorghum, and wheat) with 4 replicates per treatment. The analytical method that resulted in the lowest d and greatest S was considered desirable because it was presumably representative of increased movement of particles to their appropriate sieve. Analytical method affected d and S ( ≤ 0.05) measured by both standards. Inclusion of sieve agitators and dispersion agent in the sieve stack resulted in the lowest d, regardless of sieving time. Inclusion of dispersion agent reduced d ( ≤ 0.05) by 32 and 36 µm when shaken for 10 and 15 min, respectively, compared to the same sample analyzed without dispersion agent. The addition of the dispersion agent also increased S. The dispersion agent increased the quantity of very fine particles collected in the pan; therefore, S was significantly greater ( ≤ 0.05). Corn and sorghum ground using the same mill parameters had similar d ( > 0.05), but wheat ground using the same mill parameters was 120 to 104 µm larger ( ≤ 0.05) than corn and sorghum, respectively. Both sieve agitators and dispersion agent should be included when conducting particle size analysis. The results indicate that 10 and 15 min of sieving time produced similar results.

  11. The impact of place of enrollment and delay to reperfusion on 90-day post-infarction mortality in the ASSENT-4 PCI trial: assessment of the safety and efficacy of a new treatment strategy with percutaneous coronary intervention.

    PubMed

    Ross, Allan M; Huber, Kurt; Zeymer, Uwe; Armstrong, Paul W; Granger, Christopher B; Goldstein, Patrick; Bogaerts, Kris; Van de Werf, Frans

    2009-10-01

    We have performed a retrospective analysis of the data stratified by time to treatment and by enrollment site: percutaneous coronary intervention hospitals (PCIH), nonpercutaneous coronary intervention hospitals (NoPCIH), or in a pre-hospital setting (PreH). The ASSENT-4 PCI (Assessment of the Safety and Efficacy of a New Treatment Strategy with Percutaneous Coronary Intervention) trial intended to test the hypothesis that in ST-segment elevation myocardial infarction (STEMI) patients an upfront fibrinolytic bolus before PCI ("facilitated PCI") compared with primary PCI would benefit STEMI patients facing a long pre-PCI delay. Seven hundred forty-nine patients (45%) presented directly to PCIH, 578 (34%) presented to NoPCIH, and 334 (20%) were randomized and initially treated in the PreH setting. Patients in the PreH-facilitated group had the shortest delays (pain-to-fibrinolytic treatment 125 min) and the lowest 90-day mortality (3.1%). Among patients randomized to primary PCI, the shortest time from pain to first balloon was similarly in the PreH group (223 min). They had the lowest mortality of the primary PCI patient groups (4.1%). The highest mortality (8.4%) was in patients presenting to a PCIH and assigned to the facilitated strategy. Their pain-to-lysis time was 174 min and pain-to-PCI time 266 min (or 92 min after lysis). Few patients fit the target population, long delays to PCI for whom facilitated PCI was designed. Patients treated early after pain onset in the PreH setting do well after a facilitated approach. Despite limitations of post hoc subgroup analysis, these observations suggest caution in extrapolating the results of the ASSENT-4 trial to the "real world" where many patients might have potentially short pain-to-fibrinolysis time but are facing a long transport time to primary PCI.

  12. Door-to-balloon delays before primary angioplasty in the Regional Acute Myocardial Infarction Registry of Brittany. An analysis of the Observatoire Régional Breton sur l'Infarctus du myocarde (ORBI).

    PubMed

    Leurent, Guillaume; Fougerou, Claire; Pennec, Pierre-Yves; Filippi, Emmanuelle; Moquet, Benoît; Druelles, Philippe; Hacot, Jean-Philippe; Rialan, Antoine; Rouault, Gilles; Gervais, Renaud; Bedossa, Marc; Boulmier, Dominique; Boulanger, Bertrand; Hamon, Christian; Treuil, Josiane; Coudert, Isabelle; Courcoux, Hubert; Le Breton, Hervé

    2009-11-01

    Minimizing delays to coronary reperfusion is critical in the management of acute myocardial infarction (AMI). To determine delays in in-hospital management and factors associated with delays of over 45min. We analysed data from the Observatoire Régional Breton sur l'Infarctus, a registry of AMI patients admitted within 24h of symptom onset (July 2007 to December 2008) to an interventional cardiology centre in Brittany. Prehospital delay was defined as time between first responder arrival at the patient and patient arrival at an interventional cardiovascular centre. In-hospital delay was defined as time between admission to the interventional cardiovascular centre and first balloon inflation. Patients were grouped according to duration of in-hospital delay (>45 vs

  13. Comparability of children's sedentary time estimates derived from wrist worn GENEActiv and hip worn ActiGraph accelerometer thresholds.

    PubMed

    Boddy, Lynne M; Noonan, Robert J; Kim, Youngwon; Rowlands, Alex V; Welk, Greg J; Knowles, Zoe R; Fairclough, Stuart J

    2018-03-28

    To examine the comparability of children's free-living sedentary time (ST) derived from raw acceleration thresholds for wrist mounted GENEActiv accelerometer data, with ST estimated using the waist mounted ActiGraph 100count·min -1 threshold. Secondary data analysis. 108 10-11-year-old children (n=43 boys) from Liverpool, UK wore one ActiGraph GT3X+ and one GENEActiv accelerometer on their right hip and left wrist, respectively for seven days. Signal vector magnitude (SVM; mg) was calculated using the ENMO approach for GENEActiv data. ST was estimated from hip-worn ActiGraph data, applying the widely used 100count·min -1 threshold. ROC analysis using 10-fold hold-out cross-validation was conducted to establish a wrist-worn GENEActiv threshold comparable to the hip ActiGraph 100count·min -1 threshold. GENEActiv data were also classified using three empirical wrist thresholds and equivalence testing was completed. Analysis indicated that a GENEActiv SVM value of 51mg demonstrated fair to moderate agreement (Kappa: 0.32-0.41) with the 100count·min -1 threshold. However, the generated and empirical thresholds for GENEActiv devices were not significantly equivalent to ActiGraph 100count·min -1 . GENEActiv data classified using the 35.6mg threshold intended for ActiGraph devices generated significantly equivalent ST estimates as the ActiGraph 100count·min -1 . The newly generated and empirical GENEActiv wrist thresholds do not provide equivalent estimates of ST to the ActiGraph 100count·min -1 approach. More investigation is required to assess the validity of applying ActiGraph cutpoints to GENEActiv data. Future studies are needed to examine the backward compatibility of ST data and to produce a robust method of classifying SVM-derived ST. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  14. Measurement of excitation functions and analysis of isomeric population in some reactions induced by proton on natural indium at low energy

    NASA Astrophysics Data System (ADS)

    Muhammed Shan, P. T.; Musthafa, M. M.; Najmunnisa, T.; Mohamed Aslam, P.; Rajesh, K. K.; Hajara, K.; Surendran, P.; Nair, J. P.; Shanbagh, Anil; Ghugre, S.

    2018-06-01

    The excitation functions for reaction residues populated via 115In(p , p) 115 mIn, 115In(p , pn) 114 mIn, 115In(p , p 2 n) 113 mIn, 113In(p , p) 113 mIn, 115In(p , nα) 111 mCd, 115In(p , 3 n) 113Sn and 113In(p , n) 113Sn channels were measured over the proton energy range of 8-22 MeV using stacked foil activation technique. Theoretical analysis of the data were performed within the framework of two statistical model codes EMPIRE-3.2 and TALYS-1.8. Isomeric cross section ratio for isomeric pairs m,g 115In, m,g 114In, m,g 113In, 113Sn m,g and m,g 111Cd were determined for the first time. The dependence of isomeric cross section ratio on various factors are analysed.

  15. Time-efficiency analysis of the treatment with monolithic implant crowns in a digital workflow: a randomized controlled trial.

    PubMed

    Joda, Tim; Brägger, Urs

    2016-11-01

    The aim of the randomized controlled trial was to analyze time-efficiency of a treatment with implant crowns made of monolithic lithium disilicate (LS2) plus titanium base vs. porcelain fuse to zirconium dioxide (ZrO 2 ) in a digital workflow. Twenty study participants were included for single-tooth replacement in premolar and molar sites. Baseline was the start of the prosthetic treatment. All patients received transocclusal screw-retained implant reconstructions on a soft tissue level-type implant. The 3D implant position was captured with intraoral optical scanning (IOS). After randomization, ten patients were restored with CAD-/CAM-produced monolithic LS2-crowns bonded to prefabricated titanium abutments without any physical models (test), and ten patients with CAD-/CAM-fabricated ZrO 2 -suprastructures and hand-layered ceramic veneering with milled master models (control). Every single clinical and laboratory work step was timed in minutes and then analyzed for time-efficiency with Wilcoxon Rank Sum Tests. Direct costs were assessed for laboratory fees for first line production in Swiss Francs (CHF). Two clinical appointments were necessary for IOS and seating of all implant crowns. The mean total production time, as the sum of clinical plus laboratory work steps, was significantly different, resulting in 75.3 min (SD ± 2.1) for test and 156.6 min (SD ± 4.6) for control [P = 0.0001]. Analysis for clinical treatment sessions showed a significantly shorter mean chair time for the complete digital workflow of 20.8 min (SD ± 0.3) compared to 24.1 min (SD ± 1.1) [P = 0.001]. Even more obvious were the results for the mean laboratory work time with a significant reduction of 54.5 min (SD ± 4.9) vs. 132.5 min (SD ± 8.7), respectively [P = 0.0001]. The test workflow was more time-efficient than the controls for implant-supported crowns; notably, laboratory fabrication steps could be effectively shortened with the digital process of monolithic LS2 plus titanium base resulting in more than 30% reduced overall treatment costs. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Wait times in the emergency department for patients with mental illness

    PubMed Central

    Atzema, Clare L.; Schull, Michael J.; Kurdyak, Paul; Menezes, Natasja M.; Wilton, Andrew S.; Vermuelen, Marian J.; Austin, Peter C.

    2012-01-01

    Background: It has been suggested that patients with mental illness wait longer for care than other patients in the emergency department. We determined wait times for patients with and without mental health diagnoses during crowded and noncrowded periods in the emergency department. Methods: We conducted a population-based retrospective cohort analysis of adults seen in 155 emergency departments in Ontario between April 2007 and March 2009. We compared wait times and triage scores for patients with mental illness to those for all other patients who presented to the emergency department during the study period. Results: The patients with mental illness (n = 51 381) received higher priority triage scores than other patients, regardless of crowding. The time to assessment by a physician was longer overall for patients with mental illness than for other patients (median 82, interquartile range [IQR] 41–147 min v. median 75 [IQR 36–140] min; p < 0.001). The median time from the decision to admit the patient to hospital to ward transfer was markedly shorter for patients with mental illness than for other patients (median 74 [IQR 15–215] min v. median 152 [IQR 45–605] min; p < 0.001). After adjustment for other variables, patients with mental illness waited 10 minutes longer to see a physician compared with other patients during noncrowded periods (95% confidence interval [CI] 8 to 11), but they waited significantly less time than other patients as crowding increased (mild crowding: −14 [95% CI −12 to −15] min; moderate crowding: −38 [95% CI −35 to −42] min; severe crowding: −48 [95% CI −39 to −56] min; p < 0.001). Interpretation: Patients with mental illness were triaged appropriately in Ontario’s emergency departments. These patients waited less time than other patients to see a physician under crowded conditions and only slightly longer under noncrowded conditions. PMID:23148052

  17. Determinants of [13N]ammonia kinetics in hepatic PET experiments: a minimal recirculatory model.

    PubMed

    Weiss, Michael; Roelsgaard, Klaus; Bender, Dirk; Keiding, Susanne

    2002-12-01

    The aim of this study was the development of a modelling approach for the analysis of the systemic kinetics of the tracer nitrogen-13 ammonia administered for dynamic liver scanning. The radioactive half-life of this tracer is 9.8 min, which limits the time span in which data are available in a positron emission tomography experimental setting. A circulatory pharmacokinetic model was applied to the metabolism of ammonia in anaesthetised pigs, which incorporated data from serial measurements of [(13)N]ammonia and [(13)N]metabolite activity in arterial and portal venous blood together with blood flow rates through the portal vein and through the hepatic artery obtained over 20 min after intravenous injection of [(13)N]ammonia. Model analysis showed that up to 20 min after injection the time course of [(13)N]ammonia concentration in arterial blood is primarily determined by distribution kinetics (steady-state volume of distribution 1,856+/-531 ml kg(-1)). Simultaneous fitting of arterial ammonia and metabolite blood concentrations allowed for estimation of the hepatic [(13)N]ammonia clearance (10.25+/-1.84 ml min(-1) kg(-1)), which accounted for the formation of the circulating metabolites.

  18. Respiratory sinus arrhythmia: time domain characterization using autoregressive moving average analysis

    NASA Technical Reports Server (NTRS)

    Triedman, J. K.; Perrott, M. H.; Cohen, R. J.; Saul, J. P.

    1995-01-01

    Fourier-based techniques are mathematically noncausal and are therefore limited in their application to feedback-containing systems, such as the cardiovascular system. In this study, a mathematically causal time domain technique, autoregressive moving average (ARMA) analysis, was used to parameterize the relations of respiration and arterial blood pressure to heart rate in eight humans before and during total cardiac autonomic blockade. Impulse-response curves thus generated showed the relation of respiration to heart rate to be characterized by an immediate increase in heart rate of 9.1 +/- 1.8 beats.min-1.l-1, followed by a transient mild decrease in heart rate to -1.2 +/- 0.5 beats.min-1.l-1 below baseline. The relation of blood pressure to heart rate was characterized by a slower decrease in heart rate of -0.5 +/- 0.1 beats.min-1.mmHg-1, followed by a gradual return to baseline. Both of these relations nearly disappeared after autonomic blockade, indicating autonomic mediation. Maximum values obtained from the respiration to heart rate impulse responses were also well correlated with frequency domain measures of high-frequency "vagal" heart rate control (r = 0.88). ARMA analysis may be useful as a time domain representation of autonomic heart rate control for cardiovascular modeling.

  19. Fast analysis of curcuminoids from turmeric (Curcuma longa L.) by high-performance liquid chromatography using a fused-core column.

    PubMed

    Osorio-Tobón, J Felipe; Carvalho, Pedro I N; Barbero, Gerardo Fernández; Nogueira, Gislaine Chrystina; Rostagno, Mauricio Ariel; Meireles, Maria Angela de Almeida

    2016-06-01

    The recent development of fused-core technology in HPLC columns is enabling faster and highly efficient separations. This technology was evaluated for the development of a fast method for the analysis of main curcuminoids (curcumin, demethoxycurcumin and bisdemethoxycurcumin) present in extracts of turmeric (Curcuma longa L.). A step-by-step strategy was used to optimize temperature (40-55 °C), flow rate (1.0-2.5 mL min(-1)), mobile phase composition and equilibration time (1-5 min). A gradient method was developed using acidified water and acetonitrile combined with high column temperature (55 °C) and flow rate (2.5 mL min(-1)). Optimized conditions provided a method for the separation of these three curcuminoids in approximately 1.3 min with a total analysis time (sample-to-sample) of 7 min, including the clean-up and the re-equilibration of the column. Evaluation of chromatographic performance revealed excellent intraday and interday reproducibility (>99%), resolution (>2.23), selectivity (>1.12), peak symmetry (1.24-1.42) while presenting low limits of detection (<0.40 mg L(-1)) and quantification (<1.34 mg L(-1)). The robustness of the method was calculated according to the concentration/dilution of the sample and the injection volume. Several combinations of methanol and ethanol with water as sample solvents were evaluated and the best chromatographic results and extraction rate were obtained using 100% methanol. Finally, the developed method was validated with different extracts of turmeric rhizome and products that use turmeric in their formulation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Demonstration of the Safety and Feasibility of Robotically Assisted Percutaneous Coronary Intervention in Complex Coronary Lesions: Results of the CORA-PCI Study (Complex Robotically Assisted Percutaneous Coronary Intervention).

    PubMed

    Mahmud, Ehtisham; Naghi, Jesse; Ang, Lawrence; Harrison, Jonathan; Behnamfar, Omid; Pourdjabbar, Ali; Reeves, Ryan; Patel, Mitul

    2017-07-10

    The aims of this study were to evaluate the feasibility and technical success of robotically assisted percutaneous coronary intervention (R-PCI) for the treatment of coronary artery disease (CAD) in clinical practice, especially in complex lesions, and to determine the safety and clinical success of R-PCI compared with manual percutaneous coronary intervention (M-PCI). R-PCI is safe and feasible for simple coronary lesions. The utility of R-PCI for complex coronary lesions is unknown. All consecutive PCI procedures performed robotically (study group) or manually (control group) over 18 months were included. R-PCI technical success, defined as the completion of the procedure robotically or with partial manual assistance and without a major adverse cardiovascular event, was determined. Procedures ineligible for R-PCI (i.e., atherectomy, planned 2-stent strategy for bifurcation lesion, chronic total occlusion requiring hybrid approach) were excluded for analysis from the M-PCI group. Clinical success, defined as completion of the PCI procedure without a major adverse cardiovascular event, procedure time, stent use, and fluoroscopy time were compared between groups. A total of 315 patients (mean age 67.7 ± 11.8 years; 78% men) underwent 334 PCI procedures (108 R-PCIs, 157 lesions, 78.3% type B2/C; 226 M-PCIs, 336 lesions, 68.8% type B2/C). Technical success with R-PCI was 91.7% (rate of manual assistance 11.1%, rate of manual conversion 7.4%, rate of major adverse cardiovascular events 0.93%). Clinical success (99.1% with R-PCI vs. 99.1% with M-PCI; p = 1.00), stent use (stents per procedure 1.59 ± 0.79 with R-PCI vs. 1.54 ± 0.75 with M-PCI; p = 0.73), and fluoroscopy time (18.2 ± 10.4 min with R-PCI vs. 19.2 ± 11.4 min with M-PCI; p = 0.39) were similar between the groups, although procedure time was longer in the R-PCI group (44:30 ± 26:04 min:s vs. 36:34 ± 23:03 min:s; p = 0.002). Propensity-matched analysis confirmed that procedure time was longer in the robotic group (42:59 ± 26:14 min:s with R-PCI vs. 34:01 ± 17:14 min:s with M-PCI; p = 0.007), although clinical success remained similar (98.8% with R-PCI vs. 100% with M-PCI; p = 1.00). This study demonstrates the feasibility, safety, and high technical success of R-PCI for the treatment of complex coronary disease. Furthermore, comparable clinical outcomes, without an adverse effect on stent use or fluoroscopy time, were observed with R-PCI and M-PCI. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  1. Comparative pharmacokinetics of yohimbine in steers, horses and dogs.

    PubMed Central

    Jernigan, A D; Wilson, R C; Booth, N H; Hatch, R C; Akbari, A

    1988-01-01

    In steers, horses and dogs, the comparative pharmacokinetics of yohimbine were determined using model-independent analysis. The intravenous dose of yohimbine was 0.25 mg/kg of body weight in steers, 0.075 or 0.15 mg/kg in horses, and 0.4 mg/kg in dogs. The mean residence time (+/- SD) of yohimbine was 86.7 +/- 46.2 min in steers, 106.2 +/- 72.1 to 118.7 +/- 35.0 min in horses, and 163.6 +/- 49.7 min in dogs. The mean apparent volume of distribution of yohimbine at steady state was 4.9 +/- 1.4 L/kg for steers, 2.7 +/- 1.0 to 4.6 +/- 1.9 L/kg for horses, and 4.5 +/- 1.8 L/kg for dogs. The total body clearance of yohimbine was 69.6 +/- 35.1 mL/min/kg for steers, 34.0 +/- 19.4 to 39.6 +/- 16.6 mL/min/kg for horses, and 29.6 +/- 14.7 mL/min/kg for dogs. Between-species comparisons indicated that the mean area under the serum concentration versus time curve was significantly greater (P less than 0.05) in dogs than in horses. There were no significant differences (P greater than 0.05) between the means for the apparent volume of distribution, clearance, mean residence time, terminal rate constant, and area under the curve between horses given the two doses of yohimbine. The harmonic mean effective half-life (+/- pseudo standard deviation) of yohimbine was 46.7 +/- 24.4 min in steers, 52.8 +/- 27.8 to 76.1 +/- 23.1 min in horses, and 104.1 +/- 32.1 min in dogs. The data may explain why steers, horses, and dogs given certain sedatives and anesthetics do not relapse when aroused by an intravenous injection of yohimbine hydrochloride. PMID:3370551

  2. Differences between work and leisure in temporal patterns of objectively measured physical activity among blue-collar workers.

    PubMed

    Hallman, David M; Mathiassen, Svend Erik; Gupta, Nidhi; Korshøj, Mette; Holtermann, Andreas

    2015-09-28

    Leisure time physical activity (LTPA) is generally associated with favorable cardiovascular health outcomes, while occupational physical activity (OPA) shows less clear, or even opposite, cardiovascular effects. This apparent paradox is not sufficiently understood, but differences in temporal patterns of OPA and LTPA have been suggested as one explanation. Our aim was to investigate the extent to which work and leisure (non-occupational time) differ in temporal activity patterns among blue-collar workers, and to assess the modification of these patterns by age and gender. This study was conducted on a cross-sectional sample of male (n = 108) and female (n = 83) blue-collar workers, aged between 21 and 65 years. Physical activity and sedentary behavior were assessed using accelerometers (Actigraph GT3X+) worn on the thigh and trunk for four consecutive days. Temporal patterns of OPA and LTPA were retrieved using Exposure Variation Analysis (EVA), and expressed in terms of percentage of work and leisure time spent in uninterrupted periods of different durations (<1 min, 1-5 min, 5-10 min, 10-30 min, 30-60 min and > 60 min) of sitting, standing, and walking. Repeated measures ANOVA and linear regression analyses were used to test a) possible differences between OPA and LTPA in selected EVA derivatives, and b) the modification of these differences by age and gender. OPA showed a larger percentage time walking in brief (<5 min) periods [mean (SD): 33.4 % (12.2)], and less time in prolonged (>30 min) sitting [7.0 % (9.3)] than LTPA [walking 15.4 % (5.0); sitting 31.9 % (15.3)], even after adjustment for the difference between work and leisure in total time spent in each activity type. These marked differences in the temporal pattern of OPA and LTPA were modified by gender, but not age. We found that the temporal patterns of OPA and LTPA among blue-collar workers were markedly different even after adjustment for total physical activity time, and that this difference was modified by gender. We recommend using EVA derivatives in future studies striving to disentangle the apparent paradoxical cardiovascular effect of physical activity at work and during leisure.

  3. Time to treatment with intravenous alteplase and outcome in stroke: an updated pooled analysis of ECASS, ATLANTIS, NINDS, and EPITHET trials.

    PubMed

    Lees, Kennedy R; Bluhmki, Erich; von Kummer, Rüdiger; Brott, Thomas G; Toni, Danilo; Grotta, James C; Albers, Gregory W; Kaste, Markku; Marler, John R; Hamilton, Scott A; Tilley, Barbara C; Davis, Stephen M; Donnan, Geoffrey A; Hacke, Werner; Allen, Kathryn; Mau, Jochen; Meier, Dieter; del Zoppo, Gregory; De Silva, D A; Butcher, K S; Parsons, M W; Barber, P A; Levi, C; Bladin, C; Byrnes, G

    2010-05-15

    Early administration of intravenous recombinant tissue plasminogen activator (rt-PA) after ischaemic stroke improves outcome. Previous analysis of combined data from individual patients suggested potential benefit beyond 3 h from stroke onset. We re-examined the effect of time to treatment with intravenous rt-PA (alteplase) on therapeutic benefit and clinical risk by adding recent trial data to the analysis. We added data from ECASS III (821 patients) and EPITHET (100 patients) to a pool of common data elements from six other trials of alteplase for acute stroke (2775 patients). We used multivariate logistic regression to assess the relation of stroke onset to start of treatment (OTT) with treatment on favourable 3-month outcome (defined as modified Rankin score 0-1), mortality, and occurrence and outcome of clinically relevant parenchymal haemorrhage. The presence of an arterial occlusion was inferred from the patient's symptoms and absence of haemorrhage or other causes of ischaemic stroke. Vascular imaging was not a requirement in the trials. All patients with confirmed OTT within 360 min were included in the analysis. Treatment was started within 360 min of stroke onset in 3670 patients randomly allocated to alteplase (n=1850) or to placebo (n=1820). Odds of a favourable 3-month outcome increased as OTT decreased (p=0.0269) and no benefit of alteplase treatment was seen after around 270 min. Adjusted odds of a favourable 3-month outcome were 2.55 (95% CI 1.44-4.52) for 0-90 min, 1.64 (1.12-2.40) for 91-180 min, 1.34 (1.06-1.68) for 181-270 min, and 1.22 (0.92-1.61) for 271-360 min in favour of the alteplase group. Large parenchymal haemorrhage was seen in 96 (5.2%) of 1850 patients assigned to alteplase and 18 (1.0%) of 1820 controls, with no clear relation to OTT (p=0.4140). Adjusted odds of mortality increased with OTT (p=0.0444) and were 0.78 (0.41-1.48) for 0-90 min, 1.13 (0.70-1.82) for 91-180 min, 1.22 (0.87-1.71) for 181-270 min, and 1.49 (1.00-2.21) for 271-360 min. Patients with ischaemic stroke selected by clinical symptoms and CT benefit from intravenous alteplase when treated up to 4.5 h. To increase benefit to a maximum, every effort should be taken to shorten delay in initiation of treatment. Beyond 4.5 h, risk might outweigh benefit. None. Copyright 2010 Elsevier Ltd. All rights reserved.

  4. The German Environmental Survey for Children (GerES IV): reference values and distributions for time-location patterns of German children.

    PubMed

    Conrad, André; Seiwert, Margarete; Hünken, Andreas; Quarcoo, David; Schlaud, Martin; Groneberg, David

    2013-01-01

    Children's time-location patterns are important determinants of environmental exposure and other health-relevant factors. Building on data of the German Environmental Survey for Children (GerES IV), our study aimed at deriving reference values and distributions for time-location patterns of 3-14-year-old German children. We also investigated if GerES IV data are appropriate for evaluating associations with children's health determinants by linking them to data of the National Health Interview and Examination Survey for Children and Adolescents (KiGGS). Parents reported on the time their children usually spend at home, in other indoor environments, and outdoors. This information was characterized by statistical parameters, which were also calculated for different strata concerning socio-demography and the residential environment. Consequently, group differences were evaluated by t-tests and univariate ANOVA. Reference distributions were fitted to the time-location data by a Maximum Likelihood approach to make them also useable in probabilistic exposure modeling. Finally, associations between data on the children's physical activity as well as body weight and their outdoor time were investigated by bivariate correlation analysis and cross tabulation. On daily average, German children spend 15 h and 31 min at home, 4 h and 46 min in other indoor environments, and 3 h and 43 min outdoors. Time spent at home and outdoors decreases with age while time spent in other indoor environments increases. Differences in time-location patterns were also observed for the socio-economic status (SES) and immigration status. E.g., children with a high SES spend 24 min less outdoors than low SES children. Immigrants spend on daily average 20 min more at home and 15 min less outdoors than non-immigrant children. Outdoor time was associated with parameters of the residential environment like the building development. Children living in 1- or 2-family houses spend more time outdoors than children living in building blocks (3 h 48 min vs. 3 h 29 min). Physical activity correlates with outdoor time. For children with diminished age-specific outdoor time, a higher prevalence of obesity was observed (odds ratio: 3.2, 95% CI: 1.5-7.1). GerES IV provides a compilation of current time-location reference values and distributions on German children. This data hint to substantial differences in time-location patterns within the population to be considered in environmental health risk assessment. Copyright © 2012 Elsevier GmbH. All rights reserved.

  5. Robot-sewn ileoileal anastomosis during robot-assisted cystectomy.

    PubMed

    Loertzer, P; Siemer, S; Stöckle, M; Ohlmann, C H

    2018-07-01

    To analyze the feasibility and perioperative results of patients undergoing robot-assisted cystectomy with intracorporeal urinary diversion and robot-sewn ileoileal anastomosis. This is a mono-centric analysis of perioperative data from 48 consecutive patients undergoing robot-assisted cystectomy with intracorporeal urinary diversion and robot-sewn ileoileal anastomosis. Data include the preoperative variables, operative and postoperative course and complication rates related to bowel anastomosis. End points were time spent for anastomosis and intra- and postoperative complication rates. Median operating time was 23.0 (13-60) min for the ileoileal anastomosis. Median overall operating time was 295 (200-780) min, with a median of 282 (200-418) min and 414.0 (225-780) min for the ileum conduit (N = 35) and ileal neobladder (N = 13). Two patients developed paralytic ileus; in another patient acute peritonitis occurred, but was caused by urinary leakage and therefore unrelated to the bowel anastomosis. No anastomotic leakage was noticed. Costs for the robot-sewn anastomosis was 8€ compared to 1250€ for a stapled anastomosis which was performed in previous cases. Limitations are the non-comparative nature of the analysis and the limited number of patients. Robot-sewn ileoileal anastomosis is feasible with low complication rates. Compared to the stapled anastomosis, a robot-sewn ileoileal anastomosis may serve as an alternative and cost-saving approach.

  6. Nonhuman primate model of polytraumatic hemorrhagic shock recapitulates early platelet dysfunction observed following severe injury in humans.

    PubMed

    Schaub, Leasha J; Moore, Hunter B; Cap, Andrew P; Glaser, Jacob J; Moore, Ernest E; Sheppard, Forest R

    2017-03-01

    Platelet dysfunction has been described as an early component of trauma-induced coagulopathy. The platelet component of trauma-induced coagulopathy remains to be fully elucidated and translatable animal models are required to facilitate mechanistic investigations. We sought to determine if the early platelet dysfunction described in trauma patients could be recapitulated in a nonhuman primate model of polytraumatic hemorrhagic shock. Twenty-four male rhesus macaques weighting 7 to 14 kg were subjected to 60 minutes (min) of severe pressure-targeted controlled hemorrhagic shock (HS) with and without other injuries. After 60 min, resuscitation with 0.9% NaCl and whole blood was initiated. Platelet counts and platelet aggregation assays were performed at baseline (BSLN), end of shock (EOS; T = 60 min), end of resuscitation (EOR; T = 180 min), and T = 360 min on overall cohort. Results are reported as mean ± standard deviation (SD) or median (interquartile range). Statistical analysis was conducted using Spearmen correlation, one-way analysis of variance, two-way repeated-measures analysis of variance, paired t-test or Wilcoxon nonparametric test, with p < 0.05 considered significant. Platelet count in all injury cohorts decreased over time, but no animals developed thrombocytopenia. Correlations were observed between platelet aggregation and platelet count for all agonists: adenosine diphosphate, thrombin recognition-activating peptide-6, collagen, and arachidonic acid. Overall, compared to BSLN, platelet aggregation decreased for all agonist at EOS, EOR, and T = 360 min. When normalized to platelet count, platelet aggregation in response to agonist thrombin recognition-activating peptide-6 demonstrated no change from BSLN at subsequent time points. Aggregation to adenosine diphosphate was significantly less at EOR but not EOS or T = 360 min compared to BSLN. Platelet aggregation to collagen and arachidonic acid was not significantly different at EOS compared to BSLN but was significantly less at EOR and T = 360 min. Nonhuman primates manifest early platelet dysfunction in response to polytraumatic hemorrhagic shock, consistent with that reported in severely injured human patients. Nonhuman primate models potentially are translationally valuable for understanding the mechanisms and pathophysiology of trauma-induced platelet dysfunction.

  7. Impact of bradycardia or asystole on neonatal cardiopulmonary resuscitation at birth.

    PubMed

    Kumar, Vasantha Hs; Skrobacz, Annie; Ma, Changxing

    2017-08-01

    Fetal hypoxia from intrapartum events can lead to absent heart rate (HR) or bradycardia at birth requiring aggressive neonatal resuscitation. Neonatal resuscitation guidelines do not differentiate bradycardia (HR <100 beats/min) from absent HR at birth. Given that HR is the primary determinant of resuscitation, we hypothesize that infants with no HR at 1 min would require more extensive resuscitation with worse clinical outcome than infants with bradycardia at 1 min. A retrospective analysis was performed in infants born between 1 January 2000 and 31 December 2015 with no HR at 1 min (defined as Apgar score [AS] = 0 at 1 min; absent HR [AHR] group) or bradycardia at 1 min (AS = 1 at 1 min). Patient demographics, resuscitation characteristics and clinical outcomes were analyzed in both the groups. Apgar score was significantly lower in the AHR group over time. The AHR group had significantly higher rates of intubation, chest compression (CC) and i.v. epinephrine (i.v. epi); resulting in longer duration of CC, time to HR > 100 beats/min and duration of resuscitation. Systematic hypotension and death were higher in the AHR group. On logistic regression, CC and cord pH were significantly correlated with AS = 0 at 1 min. Gestational age, birthweight, AS at 5 min, cord pH and first blood gas pH after resuscitation were related to overall mortality. Infants with AHR at 1 min did worse than infants with bradycardia. Education focused on effective positive pressure ventilation and early use of i.v. epinephrine is essential for successful resuscitation of the depressed newborn. © 2017 Japan Pediatric Society.

  8. Immediate effects of tongue trills associated with transcutaneous electrical nerve stimulation (TENS).

    PubMed

    Fabron, Eliana Maria Gradim; Petrini, Andressa Schweitzer; Cardoso, Vanessa de Moraes; Batista, João Carlos Torgal; Motonaga, Suely Mayumi; Marino, Viviane Cristina de Castro

    2017-06-08

    To investigate vocal quality variability after applying tongue trills associated with transcutaneous electrical nerve stimulation (TENS) on the larynx of women with normal laryngeal function. Additionally, to verify the effect of this technique over time on voice quality. Participants were 40 women (average 23.4 years) without vocal complaints. The procedure involved tongue trills with or without TENS for 3 minutes, rest and repeating the technique for another 2 minutes. The participants' voices were recorded before (Pre), after three minutes (Post 3min) and after two additional minutes (Post 5min) applying the technique. TENS with two electrodes was used on the thyroid cartilage. Self-assessment, acoustic and perceptual analysis were performed. When comparing tongue trills in isolation and associated with TENS, a greater sense of stability in phonation (self-assessment) and improvement in voice quality (perceptual evaluation) was observed in the combination technique. There was no statistical difference in acoustics findings between tongue trills in isolation and associated with TENS. When comparing the time effect of tongue trills with TENS in self-assessment there was a perception of less muscle tension (3min) and greater comfort during phonation (5 min); in the acoustic analysis, there was an increase of F0 (3 and 5 min) and intensity (5 min) when compared to Pre-moment; in the perceptual evaluation, better voice quality (3min). Comparing tongue trills in isolation and associated with TENS, there were changes in the comfort and muscle tension perception, as well as in vocal quality. On the other hand, tongue trills associated with TENS performed in 3 or 5 minutes resulted in beneficial effects on the voice identified in the assessments.

  9. Effect of dexmedetomidine on intraocular pressure in patients undergoing robot-assisted laparoscopic radical prostatectomy under total intravenous anesthesia: A randomized, double blinded placebo controlled clinical trial.

    PubMed

    Kitamura, Sakiko; Takechi, Kenichi; Nishihara, Tasuku; Konishi, Amane; Takasaki, Yasushi; Yorozuya, Toshihiro

    2018-06-05

    To study the effects of intraoperative dexmedetomidine on the intraocular pressure (IOP) in patients undergoing robot-assisted laparoscopic radical prostatectomy (RALRP) under propofol-remifentanil anesthesia. Double-blind, randomized controlled trial. Operating room. Forty consenting male patients aged ≥20 to <80 years with American Society of Anesthesiologists physical status classes I and II. The patients were randomly assigned to either dexmedetomidine (DEX) (n = 20) or control (n = 20) group. Anesthesia was induced and maintained using propofol, remifentanil, and rocuronium. In the dexmedetomidine group, dexmedetomidine was administered at 0.4 μg/kg/h immediately after anesthesia induction until the end of the surgery, whereas normal saline was administered as placebo in the control group. IOP was measured using a rebound tonometer. Time points of measuring IOP were as follows: T1: before anesthesia induction, T2: 5 min after intubation, T3: 60 min after placing patient in the Trendelenburg position, T4: 120 min after placing patient in the Trendelenburg position, T5: 180 min after placing patient in the Trendelenburg position, T6: 5 min after placing patient in a horizontal position, T7: 5 min after extubation, and T8: 30 min after extubation. A linear mixed model analysis demonstrated a significant intergroup difference in IOP over time and during pneumoperitoneum in the steep Trendelenburg position. IOP at T5 was significantly lower in the dexmedetomidine group than in the control group even after post-hoc analysis in the steep Trendelenburg position periods with Bonferroni correction. Dexmedetomidine combined with propofol decreases IOP in the steep Trendelenburg position during RALRP. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Performance analysis of 60-min to 1-min integration time rain rate conversion models in Malaysia

    NASA Astrophysics Data System (ADS)

    Ng, Yun-Yann; Singh, Mandeep Singh Jit; Thiruchelvam, Vinesh

    2018-01-01

    Utilizing the frequency band above 10 GHz is in focus nowadays as a result of the fast expansion of radio communication systems in Malaysia. However, rain fade is the critical factor in attenuation of signal propagation for frequencies above 10 GHz. Malaysia is located in a tropical and equatorial region with high rain intensity throughout the year, and this study will review rain distribution and evaluate the performance of 60-min to 1-min integration time rain rate conversion methods for Malaysia. Several conversion methods such as Segal, Chebil & Rahman, Burgeono, Emiliani, Lavergnat and Gole (LG), Simplified Moupfouma, Joo et al., fourth order polynomial fit and logarithmic model have been chosen to evaluate the performance to predict 1-min rain rate for 10 sites in Malaysia. After the completion of this research, the results show that Chebil & Rahman model, Lavergnat & Gole model, Fourth order polynomial fit and Logarithmic model have shown the best performances in 60-min to 1-min rain rate conversion over 10 sites. In conclusion, it is proven that there is no single model which can claim to perform the best across 10 sites. By averaging RMSE and SC-RMSE over 10 sites, Chebil and Rahman model is the best method.

  11. Determination of optimum time for intravenous cannulation after induction with sevoflurane and nitrous oxide in children premedicated with midazolam.

    PubMed

    Kilicaslan, Alper; Gök, Funda; Erol, Atilla; Okesli, Selmin; Sarkilar, Gamze; Otelcioglu, Seref

    2014-06-01

    It has been shown that early placement of an intravenous line in children administered sevoflurane anesthesia increased the incidence of laryngospasm and movement. However, the optimal time for safe cannulation after the loss of the eyelash reflex during the administration of sevoflurane and nitrous oxide is not known. The aim of the study was to determine the optimum time for intravenous cannulation after the induction of anesthesia with sevoflurane and nitrous oxide in children premedicated with oral midazolam. We performed a prospective, observer-blinded, up-down sequential, allocation study, and children, aged 2-6 years, ASA physical status I, scheduled for an elective procedure undergoing inhalational induction were included in the study. Anesthesia was induced with sevoflurane and nitrous oxide after premedication with oral midazolam. For the first child, 4 min after the loss of the eyelash reflex, the intravenous cannulation was attempted by an experienced anesthesiologist. The time for intravenous cannulation was considered adequate if movement, coughing, or laryngospasm did not occur. The time for cannulation was increased by 15 s if the time was inadequate in the previous patient, and conversely, the time for cannulation was decreased by 15 s if the time was adequate in the previous patient. The probit test was used in the analysis of up-down sequences. A total of 32 children were enrolled sequentially during the study period. The adequate time for effective intravenous cannulation after induction with sevoflurane and nitrous oxide in 50% and 95% of patients were 1.29 min (95% confidence interval, 0.96-1.54 min) and 1.86 min (95% confidence interval 1.58-4.35 min), respectively. We recommend waiting 2 min for attempting intravenous placement following the loss of the eyelash reflex in children sedated with midazolam and receiving an inhalation induction with sevoflurane and nitrous oxide. © 2014 John Wiley & Sons Ltd.

  12. Electroactive polymer gels based on epoxy resin

    NASA Astrophysics Data System (ADS)

    Samui, A. B.; Jayakumar, S.; Jayalakshmi, C. G.; Pandey, K.; Sivaraman, P.

    2007-04-01

    Five types of epoxy gels have been synthesized from common epoxy resins and hardeners. Fumed silica and nanoclay, respectively, were used as fillers and butyl methacrylate/acrylamide were used as monomer(s) for making interpenetrating polymer networks (IPNs) in three compositions. Swelling study, tensile property evaluation, dynamic mechanical thermal analysis, thermo-gravimetric analysis, scanning electron microscopy and electroactive property evaluation were done. The gels have sufficient mechanical strength and the time taken for bending to 20° was found to be 22 min for forward bias whereas it was just 12 min for reverse bias.

  13. Dual extraction of essential oil and podophyllotoxin from creeping juniper (Juniperus horizontalis).

    PubMed

    Cantrell, Charles L; Zheljazkov, Valtcho D; Carvalho, Camila R; Astatkie, Tess; Jeliazkova, Ekaterina A; Rosa, Luiz H

    2014-01-01

    Juniperus horizontalis Moench (Family Cupressaceae), commonly called creeping juniper, is a widely distributed species in the United States and much of Canada. It is potentially a source for two important chemical products, the anticancer drug synthetic precursor, podophyllotoxin and essential oils. The objectives of this study were to ascertain the likelihood of utilizing J. horizontalis needles for the simultaneous production of both (-)-podophyllotoxin and essential oil components and to determine the optimum distillation time (DT) needed for the production of essential oil containing a specific ratio of constituents. Eleven different distillation times were tested in this study: 20, 40, 80, 160, 180, 240, 480, 600, 720, 840, and 960 min. Total essential oil content increased with increasing distillation time from a minimum of 0.023% at 20 min to a maximum of 1.098% at 960 min. The major constituents present in the oil were alpha-pinene, sabinene, and limonene. The percent concentration of sabinene in the essential oil varied from a high of 46.6% at 80 min to a low of 30.2% at 960 min, that of limonene changed very little as a result of distillation time and remained near 30% for all distillation times, whereas the concentration of alpha-pinene was 9.6% at 20 min DT and decreased to 4.2% at 960 min. Post distillation analysis of needles revealed elevated amounts of (-)-podophyllotoxin remaining in the tissue varied in the amount of podophyllotoxin present, from a low of 0.281% to a high of 0.364% as compared to undistilled needles which gave 0.217% podophyllotoxin. As a result of this study, specific essential oil components can now be targeted in J. horizontalis by varying the distillation time. Furthermore, needles can be successfully utilized as a source of both essential oil and podophyllotoxin, consecutively.

  14. Microwave-immobilized polybutadiene stationary phase for reversed-phase high-performance liquid chromatography.

    PubMed

    Lopes, Nilva P; Collins, Kenneth E; Jardim, Isabel C S F

    2004-03-19

    Polybutadiene (PBD) has been immobilized on high-performance liquid chromatography (HPLC) silica by microwave radiation at various power levels (52-663 W) and actuation times (3-60 min). Columns prepared from these reversed-phase HPLC materials, as well as from similar non-irradiated materials, were tested with standard sample mixtures and characterized by elemental analysis (%C) and infrared spectroscopy. A microwave irradiation of 20 min at 663 W gives a layer of immobilized PBD that presented good performance. Longer irradiation times give thicker immobilized layers having less favorable chromatographic properties.

  15. Effects of chronic low back pain, age and gender on vertical spinal creep.

    PubMed

    Kanlayanaphotporn, R; Trott, P; Williams, M; Fulton, I

    2003-05-15

    This study investigated the effect of chronic low back pain, age, gender, and time of measurement on the magnitude of vertical spinal creep (VSC) and its recovery. A mixed design, involving three independent variables (chronic low back pain, age, and gender) and one repeated variable (time), was used. One hundred and six subjects of both genders, with and without chronic low back pain, aged between 20 and 60 years, participated in the study. The measurement of VSC and its recovery was performed using a seated stadiometer that allowed continuous measurement of VSC without changing the subject's posture over 25 min. Unloaded VSC was measured during the initial 5 min, followed by 10 min with an additional load of 15% of the subject's body weight and then for a further 10 min after the removal of the load. Subjects were grouped into one of eight categories according to the presence of chronic low back pain, age (20-39 years or 40-60 years) and gender. Repeated measures analysis of variance was computed. A significant increase in VSC with time of measurement was observed (p<0.001). No significant main effects for chronic low back pain, age, or gender were found at any time during the 25-min VSC testing protocol. Significant interactions were found between age and gender during the loaded (p=0.02) and unloaded (p=0.02) phases. A significant interaction was found between chronic low back pain and gender at the end of the unloaded phase (p=0.04). These findings suggest a combined influence of chronic low back pain, age, and gender on VSC and its recovery and that the dominance of each variable changed with the time of the measurement. Thus, subjects who differ in the presence of chronic low back pain, age, and gender should not be combined for statistical analysis of VSC and its recovery.

  16. Association between maternal education and objectively measured physical activity and sedentary time in adolescents

    PubMed Central

    Sherar, Lauren B; Griffin, Tom P; Ekelund, Ulf; Cooper, Ashley R; Esliger, Dale W; van Sluijs, Esther M F; Bo Andersen, Lars; Cardon, Greet; Davey, Rachel; Froberg, Karsten; Hallal, Pedro C; Janz, Kathleen F; Kordas, Katarzyna; Kriemler, Susi; Pate, Russell R; Puder, Jardena J; Sardinha, Luis B; Timperio, Anna F; Page, Angie S

    2016-01-01

    Background Investigating socioeconomic variation in physical activity (PA) and sedentary time is important as it may represent a pathway by which socioeconomic position (SEP) leads to ill health. Findings on the association between children's SEP and objectively assessed PA and/or sedentary time are mixed, and few studies have included international samples. Objective Examine the associations between maternal education and adolescent's objectively assessed PA and sedentary time. Methods This is an observational study of 12 770 adolescents (10–18 years) pooled from 10 studies from Europe, Australia, Brazil and the USA. Original PA data were collected between 1997 and 2009. The associations between maternal education and accelerometer variables were examined using robust multivariable regression, adjusted for a priori confounders (ie, body mass index, monitor wear time, season, age and sex) and regression coefficients combined across studies using random effects meta-analyses. Analyses were conducted in March 2014. Results Adolescents of university educated mothers spent more time sedentary (9.5 min/day, p=0.005) and less time in light activity (10 min/day, p<0.001) compared with adolescents of high school educated mothers. Pooled analysis across two studies from Brazil and Portugal (analysed separately because of the different coding of maternal education) showed that children of higher educated mothers (tertiary vs primary/secondary) spent less time in moderate to vigorous PA (MVPA) (6.6 min/day, p=0.001) and in light PA (39.2 min/day: p<0.001), and more time sedentary (45.9 min/day, p<0.001). Conclusions Across a number of international samples, adolescents of mothers with lower education may not be at a disadvantage in terms of overall objectively measured PA. PMID:26802168

  17. One-dimensional growth of hexagonal rods of metastable h-MoO3 using one-pot, rapid and environmentally benign supercritical fluid processing

    NASA Astrophysics Data System (ADS)

    Thangasamy, Pitchai; Shanmugapriya, Vadivel; Sathish, Marappan

    2018-05-01

    A facile and one-pot supercritical fluid method was demonstrated for the synthesis of phase pure crystalline h-MoO3 microrods within a short reaction time of 5 min at 400 °C. The formation of h-MoO3 was confirmed by X-ray diffraction (XRD), Fourier transform infrared (FT-IR) and Raman spectroscopic analysis. Scanning electron microscopy (SEM) and Transmission electron microscopy (TEM) images clearly revealed the formation of hexagonal h-MoO3 rods. Further, photoluminescence emission peaks corresponding to band to band transition was observed in the h-MoO3 microrods. It was observed that when increasing the reaction time from 5 min to 30 min at 400 °C, h-MoO3 microrods undergoes disintegration to α-MoO3 thin nanorods. Interestingly, h-MoO3 microrods were also formed in a reaction time of 30 min at 400 °C when reducing the volume of nitric acid from 1 mL to ∼0.5 mL. The short reaction time and simple synthetic strategy makes this method can be suitable for the synthesis of other semiconductor nanomaterials for diverse applications.

  18. Analysis of organic volatile flavor compounds in fermented stinky tofu using SPME with different fiber coatings.

    PubMed

    Liu, Yuping; Miao, Zhiwei; Guan, Wei; Sun, Baoguo

    2012-03-26

    The organic volatile flavor compounds in fermented stinky tofu (FST) were studied using SPME-GC/MS. A total of 39 volatile compounds were identified, including nine esters, seven alcohols, five alkenes, four sulfides, three heterocycles, three carboxylic acids, three ketones, two aldehydes, one phenol, one amine and one ether. These compounds were determined by MS, and conformed by comparison of the retention times of the separated constituents with those of authentic samples and by comparison of retention indexes (RIs) of separated constituents with the RIs reported in the literature. The predominant volatile compound in FST was indole, followed by dimethyl trisulfide, phenol, dimethyl disulfide and dimethyl tetrasulfide. In order to find a better extraction time, the extraction times was optimized for each type of SPME fiber; the results show that the best extraction time for Carboxen/PDMS is 60 min, for PDMS/DVB 30 min, for DVB/CAR/PDMS 60 min and for PDMS 75 min. Of the four fibers used in this work, Carboxen/PDMS is found to be the most suitable to extract the organic volatile flavor compounds in fermented stinky tofu.

  19. Effect of perioperative inefficiency on neurosurgical theatre efficacy: A 15-year analysis.

    PubMed

    Kamat, Ameya S; Parker, Andrew

    2015-01-01

    Effective utilisation of operating theatre time is an important issue in neurosurgery. There is a commonly held belief amongst surgeons that throughput of theatre is decreasing secondary to worsening perioperative delays. The aim of this paper is to explore some of the factors that lead to delays in the perioperative period by determining whether there has been a trend in the increasing length of case time over a fifteen-year period. Case notes of all elective patients who consented for surgery between January 1998 and the end of 2012 were reviewed. Only patients who underwent elective surgery were included. Variables recorded included transit time from the ward to theatre, anaesthetic time, surgical time and time spent in recovery. These were compared over the 15-year period to look for apparent trends. The total number of patients who consented for elective surgery at our institution between January 1998 and December 2012 was 6760. The mean anaesthetic time considering all operations performed was 43 mins each over the 15-year period. Anaesthetic time was deemed to be trending upwards from 1998 where the mean time was 27 -60 mins in December 2012, thus reflecting an increase of 33 mins. The mean surgical times over the 15-year period were 131 mins. However in 1998, mean surgical time was 127 mins compared with 133 mins in 2012. For the operations analysed, anaesthetic time seems to be increasing and has effectively doubled over a 15-year period. Surgical time and non-clinical time are shown to be virtually constant. This delays the overall theatre list and increases the cancellation rate. For compensating this, changes need to be made when allocating resources to both elective and emergency theatres. Staff recruitment needs to be assessed and internal audits need to be conducted within institutions to analyse ways to optimise the throughput of an operation theatre. If these principles are not adhered to, it will have a negative impact as our populations, and hence our case loads increase to instrumental levels. This will in turn have a negative impact on health workers and patients alike.

  20. Time series study of EUV spicules observed by SUMER/SoHO

    NASA Astrophysics Data System (ADS)

    Xia, L. D.; Popescu, M. D.; Doyle, J. G.; Giannikakis, J.

    2005-08-01

    Here we study the dynamic properties of EUV spicules seen at the solar limb. The selected data were obtained as time series in polar coronal holes by SUMER/SoHO. The short exposure time and the almost fixed position of the spectrometer's slit allow the analysis of spicule properties such as occurrence, lifetime and Doppler velocity. Our data reveal that spicules occur repeatedly at the same location with a birth rate of around 0.16/min as estimated at 10´´ above the limb and a lifetime ranging from 15 down to ≈3 min. We are able to see some spicules showing a process of “falling after rising” indicated by the sudden change of the Doppler velocity sign. A periodicity of ≈5 min is sometimes discernible in their occurrence. Most spicules have a height between 10´´ and 20´´ above the limb. Some can stretch up to 40´´; these “long macro-spicules” seem to be comprised of a group of high spicules. Some of them have an obvious periodicity in the radiance of ≈5 min.

  1. Effect of Sr Additive Amount and Holding Time on Microstructure of A390 Aluminum Alloy

    NASA Astrophysics Data System (ADS)

    Zhang, J. H.; Xing, S. M.; Han, Q. Y.; Guo, Q.; Wang, R. F.

    2017-11-01

    The microstructure of A390 alloy under different Sr additive amounts and holding times was studied by means of direct reading spectrum analysis, energy spectrum analysis, optical microscope and electron microscope. The results show that Sr has a good modification to eutectic Si, while it has a negative effect on primary silicon. The Sr addition will increase the size of primary silicon. When the addition amount of Al-10Sr alloy is 0.6%, the modification of eutectic silicon is the optimum. The Sr has a short incubation period and a fine modification at 10min, but it is more serious burning rate in small furnace smelting, and the modification effect disappears basically after 100min.

  2. Sex difference in Double Iron ultra-triathlon performance

    PubMed Central

    2013-01-01

    Background The present study examined the sex difference in swimming (7.8 km), cycling (360 km), running (84 km), and overall race times for Double Iron ultra-triathletes. Methods Sex differences in split times and overall race times of 1,591 men and 155 women finishing a Double Iron ultra-triathlon between 1985 and 2012 were analyzed. Results The annual number of finishes increased linearly for women and exponentially for men. Men achieved race times of 1,716 ± 243 min compared to 1,834 ± 261 min for women and were 118 ± 18 min (6.9%) faster (p < 0.01). Men finished swimming within 156 ± 63 min compared to women with 163 ± 31 min and were 8 ± 32 min (5.1 ± 5.0%) faster (p < 0.01). For cycling, men (852 ± 196 min) were 71 ± 70 min (8.3 ± 3.5%) faster than women (923 ± 126 min) (p < 0.01). Men completed the run split within 710 ± 145 min compared to 739 ± 150 min for women and were 30 ± 5 min (4.2 ± 3.4%) faster (p = 0.03). The annual three fastest men improved race time from 1,650 ± 114 min in 1985 to 1,339 ± 33 min in 2012 (p < 0.01). Overall race time for women remained unchanged at 1,593 ± 173 min with an unchanged sex difference of 27.1 ± 8.6%. In swimming, the split times for the annual three fastest women (148 ± 14 min) and men (127 ± 20 min) remained unchanged with an unchanged sex difference of 26.8 ± 13.5%. In cycling, the annual three fastest men improved the split time from 826 ± 60 min to 666 ± 18 min (p = 0.02). For women, the split time in cycling remained unchanged at 844 ± 54 min with an unchanged sex difference of 25.2 ± 7.3%. In running, the annual fastest three men improved split times from 649 ± 77 min to 532 ± 16 min (p < 0.01). For women, however, the split times remained unchanged at 657 ± 70 min with a stable sex difference of 32.4 ± 12.5%. Conclusions To summarize, the present findings showed that men were faster than women in Double Iron ultra-triathlon, men improved overall race times, cycling and running split times, and the sex difference remained unchanged across years for overall race time and split times. The sex differences for overall race times and split times were higher than reported for Ironman triathlon. PMID:23849631

  3. Effects of prehospital epinephrine administration on neurologically intact survival in bystander-witnessed out-of-hospital cardiac arrest patients with non-shockable rhythm depend on prehospital cardiopulmonary resuscitation duration required to hospital arrival.

    PubMed

    Funada, Akira; Goto, Yoshikazu; Tada, Hayato; Shimojima, Masaya; Hayashi, Kenshi; Kawashiri, Masa-Aki; Yamagishi, Masakazu

    2018-06-23

    The effects of prehospital epinephrine administration on post-arrest neurological outcome in out-of-hospital cardiac arrest (OHCA) patients with non-shockable rhythm remain unclear. To examine the time-dependent effectiveness of prehospital epinephrine administration, we analyzed 118,396 bystander-witnessed OHCA patients with non-shockable rhythm from the prospectively recorded all-Japan OHCA registry between 2011 and 2014. Patients who achieved prehospital return of spontaneous circulation without prehospital epinephrine administration were excluded. Patients with prehospital epinephrine administration were stratified according to the time from the initiation of cardiopulmonary resuscitation (CPR) by emergency medical service (EMS) providers to the first epinephrine administration (≤ 10, 11-19, and ≥ 20 min). Patients without prehospital epinephrine administration were stratified according to the time from CPR initiation by EMS providers to hospital arrival (≤ 10, 11-19, and ≥ 20 min). The primary outcome was 1-month neurologically intact survival (cerebral performance category 1 or 2; CPC 1-2). Multivariate logistic regression analysis demonstrated that there was no significant difference in the chance of 1-month CPC 1-2 between patients who arrived at hospital in ≤ 10 min without prehospital epinephrine administration and patients with time to epinephrine administration ≤ 19 min. However, compared to patients who arrived at hospital in ≤ 10 min without prehospital epinephrine administration, patients with time to epinephrine administration ≥ 20 min and patients who arrived at hospital in 11-19, and ≥ 20 min without prehospital epinephrine administration were significantly associated with decreased chance of 1-month CPC 1-2 (p < 0.05, < 0.05, and < 0.001, respectively). In conclusion, when prehospital CPR duration from CPR initiation by EMS providers to hospital arrival estimated to be ≥ 11 min, prehospital epinephrine administered ≤ 19 min from CPR initiation by EMS providers could improve neurologically intact survival in bystander-witnessed OHCA patients with non-shockable rhythm.

  4. A 5-year analysis of the helicopter air mercy service in Richards Bay, South Africa.

    PubMed

    D'Andrea, P A; van Hoving, D J; Wood, D; Smith, W P

    2014-02-01

    A helicopter emergency medical service (HEMS) was established in 2005 in Richards Bay, KwaZulu-Natal, South Africa, to provide primary response and inter-facility transfers to a largely rural area with a population of 3.4 million people. To describe the first 5 years of operation of the HEMS. A chart review of all flights from 1 January 2006 to 31 December 2010 was conducted. A total of 1 429 flights were undertaken; 3 were excluded from analysis (missing folders). Most flights (88.4%) were inter-facility transfers (IFTs). Almost 10% were cancelled after takeoff. The breakdown by age was 61.9% adult, 15.1% paediatric and 21.6% neonate. The main indications for IFTs were obstetrics (34.5%), paediatrics (27.9%) and trauma (15.9%). For primary response most cases were trauma (72.9%) and obstetrics (11.3%). The median on-scene time for neonates was significantly longer (48 min, interquartile range (IQR) 35 - 64 min) than that for adults (36 min, IQR 26 - 48; p < 0.001) and paediatrics (36 min, IQR 25 - 51; p < 0.02). On-scene times for doctor-paramedic crews (45 min, IQR 27 - 50) were significantly longer than for paramedic-only crews (38 min, IQR 27 - 57; p < 0.001). The low flight-to-population ratio and primary response rate may indicate under-utilisation of the air medical service in an area with a shortage of advanced life support crews and long transport distances. Further studies on HEMSs in rural Africa are needed, particularly with regard to cost-benefit analyses, optimal activation criteria and triage systems.

  5. Hyperventilation accelerates rise in arterial blood concentrations of sevoflurane in gynecologic patients.

    PubMed

    Lu, Chih-Cherng; Lin, Tso-Chou; Hsu, Che-Hao; Yu, Mu-Hsien; Ku, Chih-Hung; Chen, Ta-Liang; Chen, Ruei-Ming; Ho, Shung-Tai

    2013-02-01

    We investigated whether ventilation volumes affected arterial blood sevoflurane concentration (A (sev)) and its uptake into the body during general anesthesia. Thirty female patients undergoing elective gynecologic surgery were randomly allocated into three groups: hyperventilation, normal ventilation, and hypoventilation. Inspiratory (CI(sev)) and end-tidal ((sev)) sevoflurane concentrations were routinely measured by infrared analysis, and A (sev) were analyzed by gas chromatography for 40 min after intubation. Cardiac index and total peripheral vascular resistance were measured with a Finometer. During the first 10 min after sevoflurane administration, A (sev) in the hyperventilation group was the highest and differed significantly from those in the normal ventilation group, followed by those in the hypoventilation group. In addition, hyperventilation significantly increased the slope of A (sev) over time in the first 5 min, but there were no differences in slopes in the 5-10, 10-20, and 20-40 min periods, which indicates no difference in sevoflurane bodily uptake among the three groups after 5 min. Hyperventilation accelerated the rate of A (sev) increase immediately after sevoflurane administration, which was time dependent with respect to different alveolar ventilation levels.

  6. Time-driven activity-based costing: A dynamic value assessment model in pediatric appendicitis.

    PubMed

    Yu, Yangyang R; Abbas, Paulette I; Smith, Carolyn M; Carberry, Kathleen E; Ren, Hui; Patel, Binita; Nuchtern, Jed G; Lopez, Monica E

    2017-06-01

    Healthcare reform policies are emphasizing value-based healthcare delivery. We hypothesize that time-driven activity-based costing (TDABC) can be used to appraise healthcare interventions in pediatric appendicitis. Triage-based standing delegation orders, surgical advanced practice providers, and a same-day discharge protocol were implemented to target deficiencies identified in our initial TDABC model. Post-intervention process maps for a hospital episode were created using electronic time stamp data for simple appendicitis cases during February to March 2016. Total personnel and consumable costs were determined using TDABC methodology. The post-intervention TDABC model featured 6 phases of care, 33 processes, and 19 personnel types. Our interventions reduced duration and costs in the emergency department (-41min, -$23) and pre-operative floor (-57min, -$18). While post-anesthesia care unit duration and costs increased (+224min, +$41), the same-day discharge protocol eliminated post-operative floor costs (-$306). Our model incorporating all three interventions reduced total direct costs by 11% ($2753.39 to $2447.68) and duration of hospitalization by 51% (1984min to 966min). Time-driven activity-based costing can dynamically model changes in our healthcare delivery as a result of process improvement interventions. It is an effective tool to continuously assess the impact of these interventions on the value of appendicitis care. II, Type of study: Economic Analysis. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Breast MRI at Very Short TE (minTE): Image Analysis of minTE Sequences on Non-Fat-Saturated, Subtracted T1-Weighted Images.

    PubMed

    Wenkel, Evelyn; Janka, Rolf; Geppert, Christian; Kaemmerer, Nadine; Hartmann, Arndt; Uder, Michael; Hammon, Matthias; Brand, Michael

    2017-02-01

    Purpose  The aim was to evaluate a minimum echo time (minTE) protocol for breast magnetic resonance imaging (MRI) in patients with breast lesions compared to a standard TE (nTE) time protocol. Methods  Breasts of 144 women were examined with a 1.5 Tesla MRI scanner. Additionally to the standard gradient-echo sequence with nTE (4.8 ms), a variant with minimum TE (1.2 ms) was used in an interleaved fashion which leads to a better temporal resolution and should reduce the scan time by approximately 50 %. Lesion sizes were measured and the signal-to-noise ratio (SNR) as well as the contrast-to-noise ratio (CNR) were calculated. Subjective confidence was evaluated using a 3-point scale before looking at the nTE sequences (1 = very sure that I can identify a lesion and classify it, 2 = quite sure that I can identify a lesion and classify it, 3 = definitely want to see nTE for final assessment) and the subjective image quality of all examinations was evaluated using a four-grade scale (1 = sharp, 2 = slight blur, 3 = moderate blur and 4 = severe blur/not evaluable) for lesion and skin sharpness. Lesion morphology and contrast enhancement were also evaluated. Results  With minTE sequences, no lesion was rated with "definitely want to see nTE sequences for final assessment". The difference of the longitudinal and transverse diameter did not differ significantly (p > 0.05). With minTE, lesions and skin were rated to be significantly more blurry (p < 0.01 for lesions and p < 0.05 for skin). There was no difference between both sequences with respect to SNR, CNR, lesion morphology, contrast enhancement and detection of multifocal disease. Conclusion  Dynamic breast MRI with a minTE protocol is feasible without a major loss of information (SNR, CNR, lesion morphology, contrast enhancement and lesion sizes) and the temporal resolution can be increased by a factor of 2 using minTE sequences. Key points   · Increase of temporal resolution for a better in-flow curve.. · Dynamic breast MRI with a shorter TE time is possible without relevant loss of information.. · Possible decrease of the overall scan time.. Citation Format · Wenkel E, Janka R, Geppert C et al. Breast MRI at Very Short TE (minTE): Image Analysis of minTE Sequences on Non-Fat-Saturated, Subtracted T1-Weighted Images. Fortschr Röntgenstr 2017; 189: 137 - 145. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Intraarticular Sacroiliac Joint Injection Under Computed Tomography Fluoroscopic Guidance: A Technical Note to Reduce Procedural Time and Radiation Dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paik, Nam Chull, E-mail: pncspine@gmail.com

    2016-07-15

    PurposeA technique for computed tomography fluoroscopy (CTF)-guided intraarticular (IA) sacroiliac joint (SIJ) injection was devised to limit procedural time and radiation dose.MethodsOur Institutional Review Board approved this retrospective analysis and waived the requirement for informed consent. Overall, 36 consecutive diagnostic or therapeutic IA SIJ injections (unilateral, 20; bilateral, 16) performed in 34 patients (female, 18; male, 16) with a mean age of 45.5 years (range 20–76 years) under CTF guidance were analyzed, assessing technical success (i.e., IA contrast spread), procedural time, and radiation dose.ResultsAll injections were successful from a technical perspective and were free of serious complications. Respective median proceduralmore » times and effective doses of SIJ injection were as follows: unilateral, 5.28 min (range 3.58–8.00 min) and 0.11 millisievert (mSv; range 0.07–0.24 mSv); and bilateral, 6.72 min (range 4.17–21.17 min) and 0.11 mSv (range 0.09–0.51 mSv).ConclusionsGiven the high rate of technical success achieved in limited time duration and with little radiation exposure, CTF-guided IA SIJ injection is a practical and low-risk procedure.« less

  9. A visual parallel-BCI speller based on the time-frequency coding strategy.

    PubMed

    Xu, Minpeng; Chen, Long; Zhang, Lixin; Qi, Hongzhi; Ma, Lan; Tang, Jiabei; Wan, Baikun; Ming, Dong

    2014-04-01

    Spelling is one of the most important issues in brain-computer interface (BCI) research. This paper is to develop a visual parallel-BCI speller system based on the time-frequency coding strategy in which the sub-speller switching among four simultaneously presented sub-spellers and the character selection are identified in a parallel mode. The parallel-BCI speller was constituted by four independent P300+SSVEP-B (P300 plus SSVEP blocking) spellers with different flicker frequencies, thereby all characters had a specific time-frequency code. To verify its effectiveness, 11 subjects were involved in the offline and online spellings. A classification strategy was designed to recognize the target character through jointly using the canonical correlation analysis and stepwise linear discriminant analysis. Online spellings showed that the proposed parallel-BCI speller had a high performance, reaching the highest information transfer rate of 67.4 bit min(-1), with an average of 54.0 bit min(-1) and 43.0 bit min(-1) in the three rounds and five rounds, respectively. The results indicated that the proposed parallel-BCI could be effectively controlled by users with attention shifting fluently among the sub-spellers, and highly improved the BCI spelling performance.

  10. Influence of ageing time on hardness, microstructure and wear behaviour of AISI2507 super duplex stainless steel

    NASA Astrophysics Data System (ADS)

    Davanageri, Mahesh; Narendranath, S.; Kadoli, Ravikiran

    2017-08-01

    The effect of ageing time on hardness, microstructure and wear behaviour of super duplex stainless AISI 2507 is examined. The material was solution treated at 1050 °C and water quenched, further the ageing has been carried out at 850 °C for 30 min, 60 min and 90 min. The chromium (Cr) and molybdenum (Mo) enriched intermetallic sigma phase (σ) were found to precipitate at the ferrite/austenite interface and within the ferrite region. The concentration of intermetallic sigma phase (σ), which was quantified by a combination of scanning electron microscopy and image analysis, increases with increasing ageing time, leading to significant increase in the hardness. The x-ray diffraction (XRD) and energy dispersive x-ray (EDX) was employed to investigate the element distribution and phase identification. Wear characterstics of the aged super duplex stainless steel were measured by varying normal loads, sliding speeds, sliding distance and compared with solution treated (as-cast) specimens. Scanning electron microscopy was used to assist in analysis of worn out surfaces. The outcomes suggested that the increase in percentage of sigma phase increases hardness and wear resistance in heat-treated specimens compared to solution treated specimens (as-cast).

  11. Observation of the solar eclipse of 20 March 2015 at the Pruhonice station

    NASA Astrophysics Data System (ADS)

    Mošna, Zbyšek; Boška, Josef; Knížová, Petra Koucká; Šindelářová, Tereza; Kouba, Daniel; Chum, Jaroslav; Rejfek, Luboš; Potužníková, Kateřina; Arikan, Feza; Toker, Cenk

    2018-06-01

    Response of the atmosphere to the Solar Eclipse on 20 March 2015 is described for mid-latitude region of Czech Republic. For the first time we show join analysis using Digisonde vertical sounding, manually processed Digisonde drift measurement, and Continuous Doppler Sounding for the solar eclipse study. The critical frequencies foE, foF1 and foF2 show changes with different time offset connected to the solar eclipse. Digisonde drift measurement shows significant vertical plasma drifts in F2 region deviating from daily mean course with amplitudes reaching 15-20 m/s corresponding to the time of solar eclipse. Continuous Doppler Sounding shows propagation of waves in the NE direction with velocities between 70 and 100 m/s with a peak 30 min after first contact. We observed increased and persistent wave activity at heights between 150 and 250 km at time about 20-40 min after beginning of SE with central period 65 min.

  12. Effect of intravenous gadolinium-DTPA on diffusion-weighted imaging of brain tumors: a short temporal interval assessment.

    PubMed

    Li, Xiang; Qu, Jin-Rong; Luo, Jun-Peng; Li, Jing; Zhang, Hong-Kai; Shao, Nan-Nan; Kwok, Keith; Zhang, Shou-Ning; Li, Yan-le; Liu, Cui-Cui; Zee, Chi-Shing; Li, Hai-Liang

    2014-09-01

    To determine the effect of intravenous administration of gadolinium (Gd) contrast medium (Gd-DTPA) on diffusion-weighted imaging (DWI) for the evaluation of normal brain parenchyma vs. brain tumor following a short temporal interval. Forty-four DWI studies using b values of 0 and 1000 s/mm(2) were performed before, immediately after, 1 min after, 3 min after, and 5 min after the administration of Gd-DTPA on 62 separate lesions including 15 meningioma, 17 glioma and 30 metastatic lesions. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and apparent diffusion coefficient (ADC) values of the brain tumor lesions and normal brain tissues were measured on pre- and postcontrast images. Statistical analysis using paired t-test between precontrast and postcontrast data were obtained on three brain tumors and normal brain tissue. The SNR and CNR of brain tumors and the SNR of normal brain tissue showed no statistical differences between pre- and postcontrast (P > 0.05). The ADC values on the three cases of brain tumors demonstrated significant initial increase on the immediate time point (P < 0.01) and decrease on following the 1 min time point (P < 0.01) after contrast. Significant decrease of ADC value was still found at 3min and 5min time point in the meningioma group (P < 0.01) with gradual normalization over time. The ADC values of normal brain tissues demonstrated significant initial elevation on the immediately postcontrast DWI sequence (P < 0.01). Contrast medium can cause a slight but statistically significant change on the ADC value within a short temporal interval after the contrast administration. The effect is both time and lesion-type dependent. © 2013 Wiley Periodicals, Inc.

  13. Mechanism-based pharmacokinetic-pharmacodynamic modeling of the antinociceptive effect of buprenorphine in healthy volunteers.

    PubMed

    Yassen, Ashraf; Olofsen, Erik; Romberg, Raymonda; Sarton, Elise; Danhof, Meindert; Dahan, Albert

    2006-06-01

    The objective of this investigation was to characterize the pharmacokinetic-pharmacodynamic relation of buprenorphine's antinociceptive effect in healthy volunteers. Data on the time course of the antinociceptive effect after intravenous administration of 0.05-0.6 mg/70 kg buprenorphine in healthy volunteers was analyzed in conjunction with plasma concentrations by nonlinear mixed-effects analysis. A three-compartment pharmacokinetic model best described the concentration time course. Four structurally different pharmacokinetic-pharmacodynamic models were evaluated for their appropriateness to describe the time course of buprenorphine's antinociceptive effect: (1) E(max) model with an effect compartment model, (2) "power" model with an effect compartment model, (3) receptor association-dissociation model with a linear transduction function, and (4) combined biophase equilibration/receptor association-dissociation model with a linear transduction function. The latter pharmacokinetic-pharmacodynamic model described the time course of effect best and was used to explain time dependencies in buprenorphine's pharmacodynamics. The model converged, yielding precise estimation of the parameters characterizing hysteresis and the relation between relative receptor occupancy and antinociceptive effect. The rate constant describing biophase equilibration (k(eo)) was 0.00447 min(-1) (95% confidence interval, 0.00299-0.00595 min(-1)). The receptor dissociation rate constant (k(off)) was 0.0785 min(-1) (95% confidence interval, 0.0352-0.122 min(-1)), and k(on) was 0.0631 ml . ng(-1) . min(-1) (95% confidence interval, 0.0390-0.0872 ml . ng(-1) . min(-1)). This is consistent with observations in rats, suggesting that the rate-limiting step in the onset and offset of the antinociceptive effect is biophase distribution rather than slow receptor association-dissociation. In the dose range studied, no saturation of receptor occupancy occurred explaining the lack of a ceiling effect for antinociception.

  14. Caffeine and Bicarbonate for Speed. A Meta-Analysis of Legal Supplements Potential for Improving Intense Endurance Exercise Performance

    PubMed Central

    Christensen, Peter M.; Shirai, Yusuke; Ritz, Christian; Nordsborg, Nikolai B.

    2017-01-01

    A 1% change in average speed is enough to affect medal rankings in intense Olympic endurance events lasting ~45 s to 8 min which for example includes 100 m swimming and 400 m running (~1 min), 1,500 m running and 4000 m track cycling (~4 min) and 2,000 m rowing (~6-8 min). To maximize the likelihood of winning, athletes utilizes legal supplements with or without scientifically documented beneficial effects on performance. Therefore, a continued systematic evidence based evaluation of the possible ergogenic effects is of high importance. A meta-analysis was conducted with a strict focus on closed-end performance tests in humans in the time domain from 45 s to 8 min. These test include time-trials or total work done in a given time. This selection criterion results in a high relevance for athletic performance. Only peer-reviewed placebo controlled studies were included. The often applied and potentially ergogenic supplements beta-alanine, bicarbonate, caffeine and nitrate were selected for analysis. Following a systematic search in Pubmed and SportsDiscuss combined with evaluation of cross references a total of 7 (beta-alanine), 25 (bicarbonate), 9 (caffeine), and 5 (nitrate) studies was included in the meta-analysis. For each study, performance was converted to an average speed (km/h) from which an effect size (ES; Cohens d with 95% confidence intervals) was calculated. A small effect and significant performance improvement relative to placebo was observed for caffeine (ES: 0.41 [0.15–0.68], P = 0.002) and bicarbonate (ES: 0.40 [0.27–0.54], P < 0.001). Trivial and non-significant effects on performance was observed for nitrate (ES: 0.19 [−0.03–0.40], P = 0.09) and beta-alanine (ES: 0.17 [−0.12–0.46], P = 0.24). Thus, caffeine's and bicarbonate's ergogenic effect is clearly documented for intense endurance performance. Importantly, for all supplements an individualized approach may improve the ergogenic effect on performance. PMID:28536531

  15. Randomised controlled non-inferiority trial of primary care-based facilitated access to an alcohol reduction website: cost-effectiveness analysis.

    PubMed

    Hunter, Rachael; Wallace, Paul; Struzzo, Pierluigi; Vedova, Roberto Della; Scafuri, Francesca; Tersar, Costanza; Lygidakis, Charilaos; McGregor, Richard; Scafato, Emanuele; Freemantle, Nick

    2017-11-03

    To evaluate the 12-month costs and quality-adjusted life years (QALYs) gained to the Italian National Health Service of facilitated access to a website for hazardous drinkers compared with a standard face-to-face brief intervention (BI). Randomised 1:1 non-inferiority trial. Practices of 58 general practitioners (GPs) in Italy. Of 9080 patients (>18 years old) approached to take part in the trial, 4529 (49·9%) logged on to the website and 3841 (84.8%) undertook online screening for hazardous drinking. 822 (21.4%) screened positive and 763 (19.9%) were recruited to the trial. Patients were randomised to receive either a face-to-face BI or access via a brochure from their GP to an alcohol reduction website (facilitated access). The primary outcome is the cost per QALY gained of facilitated access compared with face-to-face. A secondary analysis includes total costs and benefits per 100 patients, including number of hazardous drinkers prevented at 12 months. The average time required for the face-to-face BI was 8 min (95% CI 7.5 min to 8.6 min). Given the maximum time taken for facilitated access of 5 min, face-to-face is an additional 3 min: equivalent to having time for another GP appointment for every three patients referred to the website. Complete case analysis adjusting for baseline the difference in QALYs for facilitated access is 0.002 QALYs per patient (95% CI -0.007 to 0.011). Facilitated access to a website to reduce hazardous drinking costs less than a face-to-face BI given by a GP with no worse outcomes. The lower cost of facilitated access, particularly in regards to investment of time, may facilitate the increase in provision of BIs for hazardous drinking. NCT01638338;Post-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Effect of Time Lenght Fermentation to Katsuobushi Oxidation Rate As Fish Flavor Based

    NASA Astrophysics Data System (ADS)

    Amalia, U.; Rianingsih, L.; Wijayanti, I.

    2018-02-01

    Katsuobushi or dried smoked skipjack had a distinctive flavor and widely used in traditional Japanese cuisine. This study aimed to evaluate the oxidation rate of Katsuobushi with different lenght fermentation. The processing treatment of the product were the differences of fish boiling time (30 min and 60 min) and the lenght of fermentation: 1 week, 2 weeks and 3 weeks. The glutamic acid content, the oxidation rate (thiobarbituric acid and peroxide value) and Total Plate Count of katsuobushi were analyzed statistically using analysis of varians. Significant differences were found among 3 weeks of fermentation compare to 1 weeks fermentation (P < 0.05). The conclusion of this study was katsuobushi with 60 min boiling and 3 weeks fermentation was potential to be developed become basic ingredients for the fish flavor.

  17. Investigations into the efficacy of different procedures for surgical hand disinfection between consecutive operations.

    PubMed

    Rehork, B; Rüden, H

    1991-10-01

    In order to examine whether thorough surgical hand disinfection (handwashing plus hand disinfection) between consecutive operations is necessary, tests were carried out simulating normal clinical conditions. The tests were performed according to the guidelines for the evaluation of disinfection procedures of the German Society for Hygiene and Microbiology. Surgical hand disinfection was as follows: handwashing with soap without antimicrobial additives and subsequent 5-min disinfection with 60% n-propanol. This was followed by simulated operations of 30 or 120 min duration with a 30-min break between operations, during which half of the test group kept on the surgical gloves, while the other half removed them. The second surgical hand disinfection was done without prior handwashing by 50% of the test group. The disinfection time was reduced from 5 to 1 min by 50% of the test group. The results were evaluated by means of explorative data analysis and inductive statistical methods. Removing the surgical gloves during the interoperative break did not result in significantly higher numbers of colony forming units (cfu) compared with retaining the gloves. This was also the case after a subsequent handwashing. At the second surgical hand disinfection, after a simulated operation of 60 min duration (including break), there was no significant difference in the numbers of cfus between the test group who had washed their hands and those who had not. Reducing the disinfection time from 5 min to 1 min was not associated with a significant increase in the number of cfus. However, after a simulated operating time of 150 min (including the break), the second surgical hand disinfection with handwashing resulted in a significantly lower number of microorganisms than disinfection alone. In half the tests, the numbers of cfu were significantly lower when the test group disinfected their hands for 5 min rather than 1 min.

  18. Evaluation of the impact of a total automation system in a large core laboratory on turnaround time.

    PubMed

    Lou, Amy H; Elnenaei, Manal O; Sadek, Irene; Thompson, Shauna; Crocker, Bryan D; Nassar, Bassam

    2016-11-01

    Growing financial and workload pressures on laboratories coupled with user demands for faster turnaround time (TAT) has steered the implementation of total laboratory automation (TLA). The current study evaluates the impact of a complex TLA on core laboratory efficiency through the analysis of the In-lab to Report TAT (IR-TAT) for five representative tests based on the different requested priorities. Mean, median and outlier percentages (OP) for IR-TAT were determined following TLA implementation and where possible, compared to the pre-TLA era. The shortest mean IR-TAT via the priority lanes of the TLA was 22min for Complete Blood Count (CBC), followed by 34min, 39min and 40min for Prothrombin time (PT), urea and potassium testing respectively. The mean IR-TAT for STAT CBC loaded directly on to the analyzers was 5min shorter than that processed via the TLA. The mean IR-TATs for both STAT potassium and urea via offline centrifugation were comparable to that processed by the TLA. The longest mean IR-TAT via regular lanes of the TLA was 62min for Thyroid-Stimulating Hormone (TSH) while the shortest was 17min for CBC. All parameters for IR-TAT for CBC and PT tests decreased significantly post- TLA across all requested priorities in particular the outlier percentage (OP) at 30 and 60min. TLA helps to efficiently manage substantial volumes of samples across all requested priorities. Manual processing for small STAT volumes, at both the initial centrifugation stage and front loading directly on to analyzers, is however likely to yield the shortest IR-TAT. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Transthoracic impedance used to evaluate performance of cardiopulmonary resuscitation during out of hospital cardiac arrest.

    PubMed

    Stecher, Frederik S; Olsen, Jan-Aage; Stickney, Ronald E; Wik, Lars

    2008-12-01

    There is a need to measure cardiopulmonary resuscitation (CPR) in order to document whether ambulance personnel follow CPR guidelines. Our goal was to do this using defibrillator technology based on changes in transthoracic impedance (TTI) produced by chest compressions and ventilations. 122 incidents of out-of-hospital cardiac arrest between May 2003 and February 2004 were analysed based on data recorded from defibrillators in Oslo EMS. New software was used to analyze chest compressions and ventilations based on changes in thoracic impedance between the defibrillator pads, as well as ECG and other event data. In total, 25+/-14% (varying from 76% to 3%) of the time chest compressions were not performed on patients without spontaneous circulation (NFR=No Flow Ratio). When adjusting for time spent on analysis of ECG, pulse check and defibrillation, NFR was 20+/-13% (varying from 70% to 3%). Mean compressions delivered per minute was 87+/-16 and the compression rate during active compressions was 117+/-9min(-1). Individual variation was 31-117min(-1) (mean) and 95-144min(-1) (active periods). A mean of 14+/-3ventilations/min was recorded, varying from 8 to 26min(-1). Compared with the rest of the episode, the first 5min had a significantly higher proportion of time without chest compressions; 30+/-17% (p<0.001) and significantly lower mean compression and ventilation rates; 80+/-19min(-1) and 12+/-4min(-1), respectively (p<0.001 in both cases). Core CPR values can be measured from TTI signals by using a standard defibrillator and new software. NFR was 25% (20% adjusted) with great rescuer variability.

  20. Time Delay of CGM Sensors

    PubMed Central

    Schmelzeisen-Redeker, Günther; Schoemaker, Michael; Kirchsteiger, Harald; Freckmann, Guido; Heinemann, Lutz; del Re, Luigi

    2015-01-01

    Background: Continuous glucose monitoring (CGM) is a powerful tool to support the optimization of glucose control of patients with diabetes. However, CGM systems measure glucose in interstitial fluid but not in blood. Rapid changes in one compartment are not accompanied by similar changes in the other, but follow with some delay. Such time delays hamper detection of, for example, hypoglycemic events. Our aim is to discuss the causes and extent of time delays and approaches to compensate for these. Methods: CGM data were obtained in a clinical study with 37 patients with a prototype glucose sensor. The study was divided into 5 phases over 2 years. In all, 8 patients participated in 2 phases separated by 8 months. A total number of 108 CGM data sets including raw signals were used for data analysis and were processed by statistical methods to obtain estimates of the time delay. Results: Overall mean (SD) time delay of the raw signals with respect to blood glucose was 9.5 (3.7) min, median was 9 min (interquartile range 4 min). Analysis of time delays observed in the same patients separated by 8 months suggests a patient dependent delay. No significant correlation was observed between delay and anamnestic or anthropometric data. The use of a prediction algorithm reduced the delay by 4 minutes on average. Conclusions: Prediction algorithms should be used to provide real-time CGM readings more consistent with simultaneous measurements by SMBG. Patient specificity may play an important role in improving prediction quality. PMID:26243773

  1. Dynamical glucometry: Use of multiscale entropy analysis in diabetes

    NASA Astrophysics Data System (ADS)

    Costa, Madalena D.; Henriques, Teresa; Munshi, Medha N.; Segal, Alissa R.; Goldberger, Ary L.

    2014-09-01

    Diabetes mellitus (DM) is one of the world's most prevalent medical conditions. Contemporary management focuses on lowering mean blood glucose values toward a normal range, but largely ignores the dynamics of glucose fluctuations. We probed analyte time series obtained from continuous glucose monitor (CGM) sensors. We show that the fluctuations in CGM values sampled every 5 min are not uncorrelated noise. Next, using multiscale entropy analysis, we quantified the complexity of the temporal structure of the CGM time series from a group of elderly subjects with type 2 DM and age-matched controls. We further probed the structure of these CGM time series using detrended fluctuation analysis. Our findings indicate that the dynamics of glucose fluctuations from control subjects are more complex than those of subjects with type 2 DM over time scales ranging from about 5 min to 5 h. These findings support consideration of a new framework, dynamical glucometry, to guide mechanistic research and to help assess and compare therapeutic interventions, which should enhance complexity of glucose fluctuations and not just lower mean and variance of blood glucose levels.

  2. Effects of elevated artificial pneumoperitoneum pressure on invasive blood pressure and levels of blood gases.

    PubMed

    Hypolito, Octavio; Azevedo, João Luiz; Gama, Fernanda; Azevedo, Otavio; Miyahira, Susana Abe; Pires, Oscar César; Caldeira, Fabiana Alvarenga; Silva, Thamiris

    2014-01-01

    to evaluate the clinical, hemodynamic, gas analysis and metabolic repercussions of high transient pressures of pneumoperitoneum for a short period of time to ensure greater security for introduction of the first trocar. sixty-seven patients undergoing laparoscopic procedures were studied and randomly distributed in P12 group: n=30 (intraperitoneal pressure [IPP] 12mmHg) and P20 group: n=37 (IPP of 20mmHg). Mean arterial pressure (MAP) was evaluated by catheterization of the radial artery; and through gas analysis, pH, partial pressure of oxygen (PaO2), partial pressure of CO2 (PaCO2), bicarbonate (HCO3) and alkalinity (BE) were evaluated. These parameters were measured in both groups at time zero before pneumoperitoneum (TP0); at time 1 (TP1) when IPP reaches 12mmHg in both groups; at time 2 (TP2) after five min with IPP=12mmHg in P12 and after 5min with IPP=20mmHg at P20; and at time 3 (TP3) after 10min with IPP=12mmHg in P12 and with return of IPP from 20 to 12mmHg, starting 10min after TP1 in P20. Different values from those considered normal for all parameters assessed, or the appearance of atypical organic phenomena, were considered as clinical changes. there were statistically significant differences in P20 group in MAP, pH, HCO3 and BE, but within normal limits. No clinical and pathological changes were observed. high and transient intra-abdominal pressure causes changes in MAP, pH, HCO3 and BE, but without any clinical impact on the patient. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  3. Spectrophotometric analysis of the effectiveness of a novel in-office laser-assisted tooth bleaching method using Er,Cr:YSGG laser.

    PubMed

    Dionysopoulos, Dimitrios; Strakas, Dimitrios; Tolidis, Kosmas; Tsitrou, Effrosyni; Koumpia, Effimia; Koliniotou-Koumpia, Eugenia

    2017-11-01

    The purpose of this in vitro study was to compare the effectiveness of a novel Er,Cr:YSGG laser-assisted in-office tooth bleaching method with a conventional method by spectrophotometric analysis of the tooth color change. Furthermore, the influence of the application time of the bleaching gel on the effectiveness of the methods and the maintenance of the results 7 days and 1 month after the treatments were also evaluated. Twenty-four bovine incisors were stained and randomly distributed into four groups. Group 1 specimens received an in-office bleaching treatment with 35% H 2 O 2 for 2 × 15 min. Group 2 specimens received the same treatment but with extended application time (2 × 20 min). In Group 3, the same in-office bleaching procedure (2 × 15 min) was carried out as that in Group 1, using Er,Cr:YSGG laser irradiation for 2 × 15 s on each specimen to catalyze the reaction of H 2 O 2 breakdown. Group 4 specimens received the same bleaching treatment as Group 3 but with extended application time (2 × 20 min). Er,Cr:YSGG laser-assisted tooth bleaching treatment is more effective than the conventional treatment regarding color change of the teeth. Application time of the bleaching agent may influence the effectiveness of the methods. The color change of the tested treatments decreases after 7 days and 1 month. The clinical relevance of this study is that this novel laser-assisted bleaching treatment may be more advantageous in color change and application time compared to the conventional bleaching treatment.

  4. Postoperative recovery after anesthesia in morbidly obese patients: a systematic review and meta-analysis of randomized controlled trials.

    PubMed

    Liu, Feng-Lin; Cherng, Yih-Giun; Chen, Shin-Yan; Su, Yen-Hao; Huang, Shih-Yu; Lo, Po-Han; Lee, Yen-Ying; Tam, Ka-Wai

    2015-08-01

    Obese patients present a challenge to safe general anesthesia because of impaired cardiopulmonary physiology and increased risks of aspiration and acute upper airway obstruction. Since studies are lacking regarding the postoperative effects on recovery from general anesthesia in morbidly obese patients, we conducted a systematic review and meta-analysis of recovery outcomes in morbidly obese patients who had undergone general anesthesia. We systematically searched the PubMed, EMBASE™, Cochrane, and Scopus™ databases for randomized controlled trials that evaluated the outcome of anesthesia with desflurane, sevoflurane, isoflurane, or propofol in morbidly obese patients. Using a random effects model, we conducted meta-analyses to assess recovery times (eye opening, hand squeezing, tracheal extubation, and stating name or birth date), time to discharge from the postanesthesia care unit (PACU), and the incidence and severity of postoperative nausea and vomiting (PONV). We reviewed results for 11 trials and found that patients given desflurane took less time: to respond to commands to open their eyes (weighted mean difference [WMD] -3.10 min; 95% confidence interval (CI): -5.13 to -1.08), to squeeze the investigator's hand (WMD -7.83 min; 95% CI: -8.81 to -6.84), to be prepared for tracheal extubation (WMD -3.88 min; 95% CI: -7.42 to -0.34), and to state their name (WMD -7.15 min; 95% CI: -11.00 to -3.30). We did not find significant differences in PACU discharge times, PONV, or the PACU analgesic requirement. Postoperative recovery was significantly faster after desflurane than after sevoflurane, isoflurane, or propofol anesthesia in obese patients. No clinically relevant differences were observed regarding PACU discharge time, incidence of PONV, or postoperative pain scores. The systematic review was registered with PROSPERO (CRD42014009480).

  5. Post-exercise heart-rate recovery correlates to resting heart-rate variability in healthy men.

    PubMed

    Molina, Guilherme Eckhardt; Fontana, Keila Elizabeth; Porto, Luiz Guilherme Grossi; Junqueira, Luiz Fernando

    2016-12-01

    The relationship between post-exercise heart-rate recovery (HRR) and resting cardiac autonomic modulation is an incompletely explored issue. To correlate HRR with resting supine and orthostatic autonomic status. HRR at the 1st, 3th, and 5th min following maximal treadmill exercise were correlated with 5-min time-domain (CV, pNN50 and rMSSD) and frequency-domain (TP, LF, HF, LFn, HFn, and LF/HF ratio) indices of heart-rate variability (HRV) in both supine and standing positions in 31 healthy physically active non-athletes men. Statistical analysis employed non-parametric tests with two-tailed p value set at 5 %. Absolute HRR and Δ %HRR at each post-exercise time did not correlated with HRV in supine position, as well as at 1st min in standing position. At the 3rd min and 5th min, these measures negatively correlated with pNN50, rMSSD, TP, and HF indices, and only in the 5th min, they showed negative correlation with HFn and positive correlation with LF, LFn, and LF/HF ratio in the standing position. Coefficient of HRR (CHRR) at the 1st min negatively correlated with pNN50 and rMSSD and at 3rd and 5th min showed positive correlation with LFn and LF/HF ratio in supine position. With HRV indices in standing position CHRR from the 1st to 5th min showed the same respective negative and positive correlations as the other measures. HRR from the 1st to 5th min post-exercise negatively correlated with parasympathetic modulation in resting orthostatic, but showed no correlation in supine position. At the 3rd and 5th min, a positive correlation with combined sympathetic-parasympathetic modulation in both positions was observed.

  6. Analysis of black pepper volatiles by solid phase microextraction-gas chromatography: A comparison of terpenes profiles with hydrodistillation.

    PubMed

    Jeleń, Henryk H; Gracka, Anna

    2015-10-30

    Solid phase microextraction (SPME) is widely used in food flavor compounds analysis in majority for profiling volatile compounds. Based on such profiles conclusions are often drawn concerning the percentage composition of volatile compounds in particular food, spices or raw materials. This paper focuses on the usefulness of SPME for the profiling of volatile compounds from spices using black pepper as an example. SPME profiles obtained in different analytical conditions were compared to the profile of pepper volatiles obtained using hydrodistillation in Clevenger apparatus. The profiles of both monoterpenes and sesquiterpenes of black pepper were highly dependent on sample weight (0.1 and 1g samples were tested), and extraction time (durations from 2 to 120min were tested), regardless of the SPME fiber used (PDMS and CAR/PDMS coatings were used). The characteristic phenomenon for extraction from dry ground pepper was the decrease of monoterpenes % share in volatiles with increasing extraction times, whereas at the same time the % contents of sesquiterpenes increased. Addition of water to ground pepper substantially changed extraction kinetics and mutual proportions of mono to sesquiterpenes compared to dry samples by minimizing changes in mono- to sesquiterpenes ratio in different extraction times. Obtained results indicate that SPME can be a fast extraction method for volatiles of black pepper. Short extraction times (2-10min) in conjunction with the fast GC analysis (2.1min) proposed here may offer fast alternative to hydrodistillation allowing black pepper terpenes characterization. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Development and application of a specially designed heating system for temperature-programmed high-performance liquid chromatography using subcritical water as the mobile phase.

    PubMed

    Teutenberg, T; Goetze, H-J; Tuerk, J; Ploeger, J; Kiffmeyer, T K; Schmidt, K G; Kohorst, W gr; Rohe, T; Jansen, H-D; Weber, H

    2006-05-05

    A specially designed heating system for temperature-programmed HPLC was developed based on experimental measurements of eluent temperature inside a stainless steel capillary using a very thin thermocouple. The heating system can be operated at temperatures up to 225 degrees C and consists of a preheating, a column heating and a cooling unit. Fast cycle times after a temperature gradient can be realized by an internal silicone oil bath which cools down the preheating and column heating unit. Long-term thermal stability of a polybutadiene-coated zirconium dioxide column has been evaluated using a tubular oven in which the column was placed. The packing material was stable after 50h of operation at 185 degrees C. A mixture containing four steroids was separated at ambient conditions using a mobile phase of 25% acetonitrile:75% deionized water and a mobile phase of pure deionized water at 185 degrees C using the specially designed heating system and the PBD column. Analysis time could be drastically reduced from 17 min at ambient conditions and a flow rate of 1 mL/min to only 1.2 min at 185 degrees C and a flow rate of 5 mL/min. At these extreme conditions, no thermal mismatch was observed and peaks were not distorted, thus underlining the performance of the developed heating system. Temperature programming was performed by separating cytostatic and antibiotic drugs with a temperature gradient using only water as the mobile phase. In contrast to an isocratic elution of this mixture at room temperature, overall analysis time could be reduced two-fold from 20 to 10 min.

  8. Automatic sleep staging using empirical mode decomposition, discrete wavelet transform, time-domain, and nonlinear dynamics features of heart rate variability signals.

    PubMed

    Ebrahimi, Farideh; Setarehdan, Seyed-Kamaledin; Ayala-Moyeda, Jose; Nazeran, Homer

    2013-10-01

    The conventional method for sleep staging is to analyze polysomnograms (PSGs) recorded in a sleep lab. The electroencephalogram (EEG) is one of the most important signals in PSGs but recording and analysis of this signal presents a number of technical challenges, especially at home. Instead, electrocardiograms (ECGs) are much easier to record and may offer an attractive alternative for home sleep monitoring. The heart rate variability (HRV) signal proves suitable for automatic sleep staging. Thirty PSGs from the Sleep Heart Health Study (SHHS) database were used. Three feature sets were extracted from 5- and 0.5-min HRV segments: time-domain features, nonlinear-dynamics features and time-frequency features. The latter was achieved by using empirical mode decomposition (EMD) and discrete wavelet transform (DWT) methods. Normalized energies in important frequency bands of HRV signals were computed using time-frequency methods. ANOVA and t-test were used for statistical evaluations. Automatic sleep staging was based on HRV signal features. The ANOVA followed by a post hoc Bonferroni was used for individual feature assessment. Most features were beneficial for sleep staging. A t-test was used to compare the means of extracted features in 5- and 0.5-min HRV segments. The results showed that the extracted features means were statistically similar for a small number of features. A separability measure showed that time-frequency features, especially EMD features, had larger separation than others. There was not a sizable difference in separability of linear features between 5- and 0.5-min HRV segments but separability of nonlinear features, especially EMD features, decreased in 0.5-min HRV segments. HRV signal features were classified by linear discriminant (LD) and quadratic discriminant (QD) methods. Classification results based on features from 5-min segments surpassed those obtained from 0.5-min segments. The best result was obtained from features using 5-min HRV segments classified by the LD classifier. A combination of linear/nonlinear features from HRV signals is effective in automatic sleep staging. Moreover, time-frequency features are more informative than others. In addition, a separability measure and classification results showed that HRV signal features, especially nonlinear features, extracted from 5-min segments are more discriminative than those from 0.5-min segments in automatic sleep staging. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. 3D modeling and characterization of a calorimetric flow rate sensor for sweat rate sensing applications

    NASA Astrophysics Data System (ADS)

    Iftekhar, Ahmed Tashfin; Ho, Jenny Che-Ting; Mellinger, Axel; Kaya, Tolga

    2017-03-01

    Sweat-based physiological monitoring has been intensively explored in the last decade with the hopes of developing real-time hydration monitoring devices. Although the content of sweat (electrolytes, lactate, urea, etc.) provides significant information about the physiology, it is also very important to know the rate of sweat at the time of sweat content measurements because the sweat rate is known to alter the concentrations of sweat compounds. We developed a calorimetric based flow rate sensor using PolydimethylSiloxane that is suitable for sweat rate applications. Our simple approach on using temperature-based flow rate detection can easily be adapted to multiple sweat collection and analysis devices. Moreover, we have developed a 3D finite element analysis model of the device using COMSOL Multiphysics™ and verified the flow rate measurements. The experiment investigated flow rate values from 0.3 μl/min up to 2.1 ml/min, which covers the human sweat rate range (0.5 μl/min-10 μl/min). The 3D model simulations and analytical model calculations covered an even wider range in order to understand the main physical mechanisms of the device. With a verified 3D model, different environmental heat conditions could be further studied to shed light on the physiology of the sweat rate.

  10. Association between leisure time physical activity and depressive symptoms in men.

    PubMed

    Sieverdes, John C; Ray, Billy M; Sui, Xuemei; Lee, Duck-Chul; Hand, Gregory A; Baruth, Meghan; Blair, Steven N

    2012-02-01

    We examined the association between depressive symptoms and physical activity (PA) in a sample of men from the Aerobics Center Longitudinal Study. Secondary analysis included stratification by age and body mass index (BMI). Our cross-sectional analysis included 9580 men, age 20-87 yr, who completed the 10-item Center for Epidemiological Studies Depression Scale during 1996-2006. A score of 10 or higher defined depressive symptoms. Four PA categories based on the 2008 PA guidelines were created from a self-report leisure time PA questionnaire: inactive (0 MET·min·wk(-1)), low (1-499 MET·min·wk(-1)), medium (500-999 MET·min·wk(-1)), and high (≥1000 MET·min·wk(-1)). There were 727 men with depressive symptoms. Cross-sectional analyses showed a significant inverse relationship between PA categories and depressive symptoms (P for trend < 0.0001). This reduction in odds was shown across all types of measured leisure time activities (odds ratios = 0.36-0.58). Compared with the inactive group, the light, medium, and high PA categories were 24%, 51%, and 51% less likely to exhibit depressive symptoms, respectively. The inverse relationship was maintained for age and BMI groups except for those 60 yr or older, who exhibited fewer depressive symptoms than other ages. Men with a BMI of 30 kg·m(-2) or higher lowered their odds of depressive symptoms for all PA categories, whereas those with a BMI less than 30 kg·m(-2) needed at least 500 MET·min·wk(-1) to show a similar association. Overall, our analyses found an inverse association between PA and depressive symptoms. Most of this benefit was seen in the medium PA category, which seemed to plateau around 500 MET·min·wk(-1). This indicates that men meeting the 2008 PA Guidelines may not only experience physical health benefits but also reduce the likelihood of depressive symptoms.

  11. Time displacement and confidence to participate in physical activity.

    PubMed

    Rhodes, Ryan E; Blanchard, Chris M

    2011-09-01

    Time spent on sedentary behaviors is often blamed for low physical activity rates, but tests of time displacement are limited. The purpose of this study was to examine time-graded assessments of self-efficacy to engage in physical activity compared to either high- or low-ranked sedentary leisure behaviors among a workplace sample. Several demographic factors were examined as moderators of time displacement. Participants were a worksite sample of 2,009 men and women who completed measures of demographics, physical activity, and self-efficacy after performing a thought listing procedure to generate their most-/least-preferred sedentary leisure-time behaviors. Repeated measures analysis of variance across four gradients of available leisure-time (20, 30, 60, 120 min) showed some evidence of displacement (20 min less confident than 120 min) when considering their most preferred sedentary behavior but not their least preferred. These results, however, were moderated by age, occupational work hours, free time, education, and physical activity status. Targeted interventions for young professionals with high work hours and limited physical activity experience seem prudent in order to improve their self-efficacy to achieve regular physical activity through sedentary behavior control.

  12. Decompression Sickness After Air Break in Prebreathe Described with a Survival Model

    NASA Technical Reports Server (NTRS)

    Conkin, J.; Pilmanis, A. A.

    2010-01-01

    Data from Brooks City-Base show the decompression sickness (DCS) and venous gas emboli (VGE) consequences of air breaks in a resting 100% O2 prebreathe (PB) prior to a hypobaric exposure. METHODS: DCS and VGE survival times from 95 controls for a 60 min PB prior to 2-hr or 4-hr exposures to 4.37 psia are statistically compared to 3 break in PB conditions: a 10 min (n=40), 20 min (n=40), or 60 min break (n=32) 30 min into the PB followed by 30 min of PB. Ascent rate was 1,524 meters / min and all exposures included light exercise and 4 min of VGE monitoring of heart chambers at 16 min intervals. DCS survival time for combined control and air breaks were described with an accelerated log logistic model where exponential N2 washin during air break was described with a 10 min half-time and washout during PB with a 60 min half-time. RESULTS: There was no difference in VGE or DCS survival times among 3 different air breaks, or when air breaks were compared to control VGE times. However, 10, 20, and 60 min air breaks had significantly earlier survival times compared to control DCS times, certainly early in the exposures. CONCLUSION: Air breaks of 10, 20, and 60 min after 30 min of a 60 min PB reduced DCS survival time. The survival model combined discrete comparisons into a global description mechanistically linked to asymmetrical N2 washin and washout kinetics based on inspired pN2. Our unvalidated regression is used to compute additional PB time needed to compensate for an air break in PB within the range of tested conditions.

  13. Modeling the effects of exercise during 100% oxygen prebreathe on the risk of hypobaric decompression sickness

    NASA Technical Reports Server (NTRS)

    Loftin, K. C.; Conkin, J.; Powell, M. R.

    1997-01-01

    BACKGROUND: Several previous studies indicated that exercise during prebreathe with 100% O2 decreased the incidence of hypobaric decompression sickness (DCS). We report a meta-analysis of these investigations combined with a new study in our laboratory to develop a statistical model as a predictive tool for DCS. HYPOTHESIS: Exercise during prebreathe increases N2 elimination in a theoretical 360-min half-time compartment decreasing the incidence of DCS. METHODS: A dose-response probability tissue ratio (TR) model with 95% confidence limits was created for two groups, prebreathe with exercise (n = 113) and resting prebreathe (n = 113), using nonlinear regression analysis with maximum likelihood optimization. RESULTS: The model predicted that prebreathe exercise would reduce the residual N2 in a 360-min half-time compartment to a level analogous to that in a 180-min compartment. This finding supported the hypothesis. The incidence of DCS for the exercise prebreathe group was significantly decreased (Chi-Square = 17.1, p < 0.0001) from the resting prebreathe group. CONCLUSIONS: The results suggested that exercise during prebreathe increases tissue perfusion and N2 elimination approximately 2-fold and markedly lowers the risk of DCS. Based on the model, the prebreathe duration may be reduced from 240 min to a predicted 91 min for the protocol in our study, but this remains to be verified. The model provides a useful planning tool to develop and test appropriate prebreathe exercise protocols and to predict DCS risks for astronauts.

  14. Supported liquid membrane coupled on-line to potentiometric stripping analysis at a mercury-coated reticulated vitreous carbon electrode for trace metal determinations in urine.

    PubMed

    Djane, N K; Armalis, S; Ndung'u, K; Johansson, G; Mathiasson, L

    1998-02-01

    A method for trace metal determinations in complex matrices is presented. The method combines supported liquid membrane (SLM) sample clean-up and enrichment with potentiometric stripping analysis (PSA) in a flow system using reticulated vitreous carbon (RVC) as the electrode material. The membrane contained 40% m/m di-2-ethylhexylphosphoric acid dissolved in kerosene. Lead was used as a model substance in high-purity water and urine samples. The samples were enriched after a simple pH adjustment. The SLM enrichment time was 10 min when the last 5 min electrodeposition on the RVC electrode at -1.0 V (versus Ag/AgCl) was performed simultaneously. The influence of various experimental parameters such as deposition time, deposition potential and flow rate on the lead signal was investigated. With a 10 min SLM enrichment including a 5 min deposition time, the detection limit for lead was 0.3 microgram l-1. The relative standard deviation for lead concentrations in the range 4-20 micrograms l-1 was 0.05%. The overall SLM-PSA system was found to be stable for at least 100 urine analyses. The method was validated by running a reference urine sample. The result obtained (five replicates) was 9.7 micrograms l-1 (standard deviation 1.8 micrograms l-1) which is within the recommended range of 9.2-10.8 micrograms l-1.

  15. Effect of pedal rate and power output on rating of perceived exertion during cycle ergometry exercise.

    PubMed

    Hamer, Mark; Boutcher, Yati N; Boutcher, Stephen H

    2005-12-01

    This study examined differentiated rating of perceived exertion (RPE), heart rate, and heart-rate variability during light cycle ergometry exercise at two different pedal rates. 30 healthy men (22.6 +/- 0.9 yr.) were recruited from a student population and completed a continuous 20-min. cycle ergometry exercise protocol, consisting of a 4-min. warm-up (60 rev./min., 30 Watts), followed by four bouts of 4 min. at different combinations of pedal rate (40 or 80 rev./min.) and power output (40 or 80 Watts). The order of the four combinations was counterbalanced across participants. Heart rate was measured using a polar heart-rate monitor, and parasympathetic balance was assessed through time series analysis of heart-rate variability. Measures were compared using a 2 (pedal rate) x 2 (power output) repeated-measures analysis of variance. RPE was significantly greater (p<.05) at 80 versus 40 rev./min. at 40 W. For both power outputs heart rate was significantly increased, and the high frequency component of heart-rate variability was significantly reduced at 80 compared with 40 rev./min. These findings indicate the RPE was greater at higher than at lower pedalling rates for a light absolute power output which contrasts with previous findings based on use of higher power output. Also, pedal rate had a significant effect on heart rate and heart-rate variability at constant power output.

  16. A localizing circumferential compression device increases survival after coral snake envenomation to the torso of an animal model.

    PubMed

    Hack, Jason B; Deguzman, Jocelyn M; Brewer, Kori L; Meggs, William J; O'Rourke, Dorcas

    2011-07-01

    Pressure immobilization bandages have been shown to delay onset of systemic toxicity after Eastern coral snake (Micrurus fulvius) envenomation to the distal extremity. To assess the efficacy of a novel compression device in delaying onset of systemic toxicity after truncal envenomations with Eastern coral snake (Micrurus fulvius) venom in a porcine model. With University approval, nine juvenile pigs (11 kg to 22 kg) were sedated, anesthetized, and intubated but not paralyzed to ensure continuous spontaneous respirations in a university animal laboratory. Each animal was injected subcutaneously with 10 mg of M. fulvius venom in a pre-selected area of the trunk. After 1 min, six animals had the application of a novel, localizing circumferential compression (LoCC) device applied to the bite site (treatment group) and three animals had no treatment (control group). The device was composed of a rigid polymer clay form molded into a hollow fusiform shape with an internal dimension of 8 × 5 × 3 cm and an elastic belt wrapped around the animal securing the device in place. Vital signs were recorded at 30-min intervals. End points included a respiratory rate below 3 breaths/min, oxygen saturation < 80%, or survival to 8 h. Survival to 8 h was analyzed using Fisher's exact test, with p < 0.05 indicating significance. Survival analysis was performed using the Mantel-Cox test to assess time to death with outcomes represented in a Kaplan-Meier Cumulative survival plot. Five of the six pigs in the treatment group survived 8 h (293-480 min). None of the control pigs survived to 8 h (Fisher's exact p = 0.04), with mean time of respiratory failure 322 min (272-382 min). Survival analysis showed a significant delay in time to event in the treatment group compared to the control group (p = 0.04). The LoCC device used in this study delayed the onset of systemic toxicity and significantly increased survival time after artificial truncal envenomation by Eastern coral snake venom. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Effects of cooking and storage on residues of cyadox in chicken muscle.

    PubMed

    Zhang, Yanling; Wang, Yulian; Huang, Lingli; Chen, Dongmei; Tao, Yanfei; Yuan, Zonghui

    2005-12-14

    The aim of this study was to investigate the depletion of residues of cyadox in chicken muscle over time. The heat stabilities of cyadox (CYX) and its two metabolites, 1,4-bisdesoxycyadox (BDCYX) and quinoxaline-2-carboxylic acid (QCA), in water, cooking oil, and as incurred residues in chicken muscle were investigated. CYX was shown to be unstable with a half-life of about 37.7 min in 100 degrees C water. In hot cooking oil at 180 degrees C, all three compounds were unstable. CYX decreased quickly and was not able to be detected after heating for 2 min. Diode-array analysis of CYX standard solution in cooking oil indicated that a portion of BDCYX was formed. The residues of CYX and BDCYX deteriorated rapidly in frozen storage, while that of QCA changed slowly. Muscles containing CYX residues were boiled, microwaved, or fried for the specified times. During boiling, CYX and BDCYX were reduced 94% and 81% in 10 min, respectively. During microwave cooking, CYX and BDCYX were reduced 54% and 47% in 2.5 min, respectively. During frying, CYX and BDCYX were reduced 86% and 76%, respectively. No significant reduction of QCA was found for the three cooking methods. The half-lives of CYX residues in cooked chicken muscles were estimated as follows: 2.22 min for CYX and 4.44 min for BDCYX by boiling; 6.66 min for CYX and 9.36 min for BDCYX by microwaving.

  18. Effect of storage temperature and equilibration time on polymethyl methacrylate (PMMA) bone cement polymerization in joint replacement surgery.

    PubMed

    Koh, Bryan T H; Tan, J H; Ramruttun, Amit Kumarsing; Wang, Wilson

    2015-11-17

    In cemented joint arthroplasty, the handling characteristics (doughing, working, and setting times) of polymethyl methacrylate (PMMA) bone cement is important as it determines the amount of time surgeons have to optimally position an implant. Storage conditions (temperature and humidity) and the time given for PMMA cement to equilibrate to ambient operating theater (OT) temperatures are often unregulated and may lead to inconsistencies in its handling characteristics. This has not been previously studied. Hence, the purpose of this study was to investigate the effect of storage temperatures on the handling characteristics of PMMA cement and the duration of equilibration time needed at each storage temperature to produce consistent and reproducible doughing, setting, and working times. SmartSet® HV cement was stored at three different controlled temperatures: 20 °C (control), 24 °C, and 28 °C for at least 24 h prior to mixing. The cement components were then brought into a room kept at 20 °C and 50 % humidity. Samples were allowed to equilibrate to ambient conditions for 15, 30, 45, and 60 min. The cement components were mixed and the dough time, temperature-versus-time curve (Lutron TM-947SD, Lutron Electronics, Inc., Coopersburg, PA), and setting time were recorded. Analysis was performed using the two-way ANOVA test (IBM SPSS Statistics V.22). At 20 °C (control) storage temperature, the mean setting time was 534 ± 17 s. At 24 °C storage temperature, the mean setting time was 414 ± 6 s (p < 0.001*) with 15 min of equilibration, 446 ± 11 s (p < 0.001*) with 30 min of equilibration, 501 ± 12 s (p < 0.001*) with 45 min of equilibration, and 528 ± 15 (p > 0.05) with 60 min of equilibration. At 28 °C storage temperature, the mean setting time was 381 ± 8 s (p < 0.001*) with 15 min of equilibration, 432 ± 30 s (p < 0.001*) with 30 min of equilibration, 487 ± 9 (p < 0.001*) with 45 min of equilibration, and 520 ± 16 s (p > 0.05) with 60 min of equilibration. This study reflects the extent to which storage temperatures and equilibration times can potentially affect the handling characteristics of PMMA cement. We recommend institutions to have a well-regulated temperature and humidity-controlled facility for storage of bone cements and a protocol to standardize the equilibration time of cements prior to use in the OT to improve consistency and reproducibility of the handling characteristics of PMMA cement.

  19. Factors associated with recovery from 1 minute Apgar score <4 in live, singleton, term births: an analysis of Malaysian National Obstetrics Registry data 2010-2012.

    PubMed

    Jeganathan, Ravichandran; Karalasingam, Shamala D; Hussein, Julia; Allotey, Pascale; Reidpath, Daniel D

    2017-04-08

    The neonatal Apgar score at 5 min has been found to be a better predictor of outcomes than the Apgar score at 1 min. A baby, however, must pass through the first minute of life to reach the fifth. There has been no research looking at predictors of recovery (Apgar scores ≥7) by 5 min in neonates with 1 min Apgar scores <4. An analysis of observational data was conducted using live, singleton, term births recorded in the Malaysian National Obstetrics Registry between 2010 and 2012. A total of 272,472 live, singleton, term births without congential anomalies were recorded, of which 1,580 (0.59%) had 1 min Apgar scores <4. Descriptive methods and bi- and multi-variable logistic regression were used to identify risk factors associated with recovery (5 min Apgar score ≥7) from 1 min Apgar scores <4. Less than 1% of births have a 1 min Apgar scores <4. Only 29.4% of neonates with 1 min Apgar scores <4 recover to a 5 min Apgar score ≥7. Among uncomplicated vaginal deliveries, after controlling for other factors, deliveries by a doctor of neonates with a 1 min Apgar score <4 had odds of recovery 2.4 times greater than deliveries of neonates with a 1 min Apgar score <4 by a nurse-midwife. Among deliveries of neonates with a 1 min Apgar score <4 by doctors, after controlling for other factors, planned and unplanned CS was associated with better odds of recovery than uncomplicated vaginal deliveries. Recovery was also associated with maternal obesity, and there was some ethnic variation - in the adjusted analysis indigenous (Orang Asal) Malaysians had lower odds of recovery. A 1 min Apgar score <4 is relatively rare, and less than a third recover by five minutes. In those newborns the qualification of the person performing the delivery and the type of delivery are independent predictors of recovery as is maternal BMI and ethnicity. These are associations only, not necessarily causes, and they point to potential areas of research into health systems factors in the labour room, as well as possible biological and cultural factors.

  20. Effects of guided breath exercise on complex behaviour of heart rate dynamics.

    PubMed

    Tavares, Bruna S; de Paula Vidigal, Giovanna; Garner, David M; Raimundo, Rodrigo D; de Abreu, Luiz Carlos; Valenti, Vitor E

    2017-11-01

    Cardiac autonomic regulation is influenced by changes in respiratory rate, which has been demonstrated by linear analysis of heart rate variability (HRV). Conversely, the complex behaviour is not well defined for HRV during this physiological state. In this sense, Higuchi Fractal Dimension is applied directly to the time series. It analyses the fractal dimension of discrete time sequences and is simpler and faster than correlation dimension and many other classical measures derived from chaos theory. We investigated chaotic behaviour of heart rate dynamics during guided breath exercises. We investigated 21 healthy male volunteers aged between 18 and 30 years. HRV was analysed 10 min before and 10 min during guided breath exercises. HRV was analysed in the time and frequency domain for linear analysis and through HFD for non-linear analysis. Linear analysis indicated that SDNN, pNN50, RMSSD, LF, HF and LF/HF increased during guided breath exercises. HFD analysis illustrated that between K max 20 to K max 120 intervals, was enhanced during guided breath exercises. Guided breath exercises acutely increased chaotic behaviour of HRV measured by HFD. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  1. Exogenous platelet-activating factor improves the motility of human spermatozoa evaluated with C.A.S.A.: optimal concentration and incubation time.

    PubMed

    Grassi, G; Cappello, N; Gheorghe, M F; Salton, L; Di Bisceglie, C; Manieri, C; Benedetto, C

    2010-11-01

    The objective of this study is to determine the optimal conditions for human semen incubation treated with exogenous platelet activating factor (ePAF) for intra-uterine insemination (IUI). This prospective study was carried out on 32 infertile men and each semen sample was processed with the ISolate Sperm Separation Medium, washed with sperm washing medium (SWM) and resuspended either in SWM alone (control samples), or with ePAF 0.1, 0.5, and 1.0 μM. Each concentration was subsequently incubated and evaluated at 5, 15, 30, and 60 min. The motility parameters were evaluated by the computer-aided sperm analysis (C.A.S.A.) system. Curvilinear velocity, straight line velocity, average path velocity, rapid and progressive motility significantly increased compared to control samples at an ePAF concentration of 0.1 μM (with at least 15 min of incubation). The best results were obtained with ePAF concentrations of: 0.1 μM (60 min of incubation) and 0.5 μM (30-60 min of incubation). In conclusion, results are enhanced when ePAF is added to standard semen preparation for IUI. An ePAF concentration of 0.1 μM, with an incubation time of 15 min, can be used for semen samples with normal motility. Whilst, for semen samples with poor motility, the ePAF concentration is best increased to 0.5 μM and/or the incubation time prolonged to 60 min.

  2. High-Throughput Microfludic Applications

    PubMed Central

    Doneanu, A.; Murphy, J.; Johnson, J.; Cohen, S.; Astarita, G.; Chakraborty, A.; Martin, LeRoy

    2013-01-01

    A novel platform was developed for the expansion of microfludic LC-MS beyond typical nanoscale applications into areas traditionally performed at analytical scales. The material used to fabricate the device allows for pressures of 12,000 psi. The integrated metal electrospray emitter supports flow rates from 100s of nl/min up to 8 μl/min and allows for the use of 150 μm in ID separation channels. Peak widths are on par with commercial ultra-high pressure LC instrumentation and cycle times as low as 10 min. System versatility will be demonstrated by several examples including intact proteins analysis, lipidomics and biopharmaceutical applications. All experiments were performed using a nanoflow system coupled with an oaTOF mass spectrometer fitted with an electrospray ionization source designed to accommodate the microfluidic device. The emitter is connected to a packed channel by zero dead-volume connections and incorporates the use of nebulising gas. The separation channel was 150 μm × 5 cm and packed with sub-2-μm reverse-phased particles of various chemistries. For intact protein analysis, using Ribonuclease A, Cyctochrome C, Holotransferrin and Apomyoglobin, good resolution was achieved using shorter alkyl chain resins. Additionally, light and heavy chains of reduced monoclonal antibodies could be separated. Separations were performed at 80°C, using a 3 μL/min linear gradient from 20% to 55% ACN over 5 min. Applicability for biopharmaceutical use is shown with minute amounts of Trastuzumab, demonstrating peak widths less than 6 s with 90% sequence coverage. Methionine oxidation and sites of glycosylation were also detected. The method was also employed for lipid analysis showing improved separation for the major classes, particularly inter and intra forms. The microfluidic system offered high retention time reproducibility with RSD values smaller than 0.2%. This is especially useful for lipidomic analysis, which requires the comparison of a large number of LC-MS chromatograms from multiple sample sets.

  3. Toward Capturing Momentary Changes of Heart Rate Variability by a Dynamic Analysis Method

    PubMed Central

    Zhang, Haoshi; Zhu, Mingxing; Zheng, Yue; Li, Guanglin

    2015-01-01

    The analysis of heart rate variability (HRV) has been performed on long-term electrocardiography (ECG) recordings (12~24 hours) and short-term recordings (2~5 minutes), which may not capture momentary change of HRV. In this study, we present a new method to analyze the momentary HRV (mHRV). The ECG recordings were segmented into a series of overlapped HRV analysis windows with a window length of 5 minutes and different time increments. The performance of the proposed method in delineating the dynamics of momentary HRV measurement was evaluated with four commonly used time courses of HRV measures on both synthetic time series and real ECG recordings from human subjects and dogs. Our results showed that a smaller time increment could capture more dynamical information on transient changes. Considering a too short increment such as 10 s would cause the indented time courses of the four measures, a 1-min time increment (4-min overlapping) was suggested in the analysis of mHRV in the study. ECG recordings from human subjects and dogs were used to further assess the effectiveness of the proposed method. The pilot study demonstrated that the proposed analysis of mHRV could provide more accurate assessment of the dynamical changes in cardiac activity than the conventional measures of HRV (without time overlapping). The proposed method may provide an efficient means in delineating the dynamics of momentary HRV and it would be worthy performing more investigations. PMID:26172953

  4. Pre-clinical validation of a new intra-operative "dual beam Doppler" blood flowmeter in an artificial circuit.

    PubMed

    Cikirikcioglu, Mustafa; Cikirikcioglu, Y Banu; Khabiri, Ebrahim; Djebaili, M Karim; Kalangos, Afksendiyos; Walpoth, Beat H

    2006-01-01

    Intra-operative flow measurement during coronary or peripheral bypass operations is helpful for ruling out technical failures and for prediction of complication and patency rates. Preclinical validation of the flowmeters is required in order to rely on the intra-operatively measured results. The aim of this study is to evaluate a new "dual beam Doppler" blood flowmeter before clinical application and to compare it with the established "transit time flow measure-ment" technique in an artificial circuit. Measurements were performed in an experimental flow model using pig blood and pig arteries. Three different flowmeters were used: Quantix OR (dual beam doppler flowmeter), CardioMed (transit time flowmeter), and Transonic (transit time flowmeter). Three validation tests were performed to assess correlation, precision, and repeatability of devices. (1) Correlation and agreement analysis was performed with various flow amounts (10-350 mL/min) (n = 160). (2) Device reproducibility and measurement stability were tested with a constant flow (flow amount = 300 mL/min) (n = 30). (3) A user accuracy test (intra- and inter-observer variability) was performed by 5 different observers with a constant flow (flow amount = 205 mL/min) (n = 75). Time collected true flow was used as a reference method in all steps and all tests were performed in a blind manner. Results are shown as mean values +/- standard deviations. Pear-son's correlation and Bland-Altman plot analyses were used to compare measurements. The mean flow was 167 +/- 98 mL/min for true flow and 162 +/- 94 mL/min, 165 +/- 94 mL/min, and 166 +/- 100 mL/min for Quantix OR, CardioMed, and Transonic, respectively. Correlation coefficients between Quantix OR, Medi-Stim, Transonic, and time collected true flow were over 0.98 (P = .01). Most of the measured results ( > 90%) were between +/- 1.96 SD agreement limits in Bland and Altman plot analysis. All devices showed good results in the reproducibility test. During the user accuracy test, larger variance changes were observed between intra- and inter-observer results with the dual beam Doppler flowmeter compared to the 2 used transit time flowmeters when used for single sided vessel access without stabilization device (available from the manufacturer). All 3 tested flowmeters showed an excellent correlation to the true flow in an artificial circuit and the accuracy of the tested devices was within agreement limits. Reproducibility of all devices was good and linear. The new dual beam Doppler flow measurement technique compares favorably to the classic transit time method. Clinical use may depend on operator, location, and condition, thus more studies may be required to ensure uniform results using the currently available blood flow measurement devices.

  5. Rapid ELISA Using a Film-Stack Reaction Field with Micropillar Arrays

    PubMed Central

    Suzuki, Yuma; Morioka, Kazuhiro; Ohata, Soichiro; Nakajima, Hizuru; Uchiyama, Katsumi; Yang, Ming

    2017-01-01

    A film-stack reaction field with a micropillar array using a motor stirrer was developed for the high sensitivity and rapid enzyme-linked immunosorbent assay (ELISA) reaction. The effects of the incubation time of a protein (30 s, 5 min, and 10 min) on the fluorescence intensity in ELISAs were investigated using a reaction field with different micropillar array dimensions (5-µm, 10-µm and 50-µm gaps between the micropillars). The difference in fluorescence intensity between the well with the reaction field of 50-µm gap for the incubation time of 30 s and the well without the reaction field with for incubation time of 10 min was 6%. The trend of the fluorescence intensity in the gap between the micro pillars in the film-stack reaction field was different between the short incubation time and the long incubation time. The theoretical analysis of the physical parameters related with the biomolecule transport indicated that the reaction efficiency defined in this study was the dominant factor determining the fluorescence intensity for the short incubation time, whereas the volumetric rate of the circulating flow through the space between films and the specific surface area were the dominant factors for the long incubation time. PMID:28696378

  6. Rapid ELISA Using a Film-Stack Reaction Field with Micropillar Arrays.

    PubMed

    Suzuki, Yuma; Morioka, Kazuhiro; Ohata, Soichiro; Shimizu, Tetsuhide; Nakajima, Hizuru; Uchiyama, Katsumi; Yang, Ming

    2017-07-11

    A film-stack reaction field with a micropillar array using a motor stirrer was developed for the high sensitivity and rapid enzyme-linked immunosorbent assay (ELISA) reaction. The effects of the incubation time of a protein (30 s, 5 min, and 10 min) on the fluorescence intensity in ELISAs were investigated using a reaction field with different micropillar array dimensions (5-µm, 10-µm and 50-µm gaps between the micropillars). The difference in fluorescence intensity between the well with the reaction field of 50-µm gap for the incubation time of 30 s and the well without the reaction field with for incubation time of 10 min was 6%. The trend of the fluorescence intensity in the gap between the micro pillars in the film-stack reaction field was different between the short incubation time and the long incubation time. The theoretical analysis of the physical parameters related with the biomolecule transport indicated that the reaction efficiency defined in this study was the dominant factor determining the fluorescence intensity for the short incubation time, whereas the volumetric rate of the circulating flow through the space between films and the specific surface area were the dominant factors for the long incubation time.

  7. Study of 1-min rain rate integration statistic in South Korea

    NASA Astrophysics Data System (ADS)

    Shrestha, Sujan; Choi, Dong-You

    2017-03-01

    The design of millimeter wave communication links and the study of propagation impairments at higher frequencies due to a hydrometeor, particularly rain, require the knowledge of 1-min. rainfall rate data. Signal attenuation in space communication results are due to absorption and scattering of radio wave energy. Radio wave attenuation due to rain depends on the relevance of a 1-min. integration time for the rain rate. However, in practice, securing these data over a wide range of areas is difficult. Long term precipitation data are readily available. However, there is a need for a 1-min. rainfall rate in the rain attenuation prediction models for a better estimation of the attenuation. In this paper, we classify and survey the prominent 1-min. rain rate models. Regression analysis was performed for the study of cumulative rainfall data measured experimentally for a decade in nine different regions in South Korea, with 93 different locations, using the experimental 1-min. rainfall accumulation. To visualize the 1-min. rainfall rate applicable for the whole region for 0.01% of the time, we have considered the variation in the rain rate for 40 stations across South Korea. The Kriging interpolation method was used for spatial interpolation of the rain rate values for 0.01% of the time into a regular grid to obtain a highly consistent and predictable rainfall variation. The rain rate exceeded the 1-min. interval that was measured through the rain gauge compared to the rainfall data estimated using the International Telecommunication Union Radio Communication Sector model (ITU-R P.837-6) along with the empirical methods as Segal, Burgueno et al., Chebil and Rahman, logarithmic, exponential and global coefficients, second and third order polynomial fits, and Model 1 for Icheon regions under the regional and average coefficient set. The ITU-R P. 837-6 exhibits a lower relative error percentage of 3.32% and 12.59% in the 5- and 10-min. to 1-min. conversion, whereas the higher error percentages of 24.64%, 46.44% and 58.46% for the 20-, 30- and 60-min. to 1-min., conversion were obtained in the Icheon region. The available experimental rainfall data were sampled on equiprobable rain-rate values where the application of these models to experimentally obtained data exhibits a variable error rate. This paper aims to provide a better survey of various conversion methods to model a 1-min. rain rate applicable to the South Korea regions with a suitable contour plot at 0.01% of the time.

  8. Influence of acute consumption of caffeine vs. placebo over Bia-derived measurements of body composition: a randomized, double-blind, crossover design.

    PubMed

    Williamson, Cassie M; Nickerson, Brett S; Bechke, Emily E; McLester, Cherilyn N; Kliszczewicz, Brian M

    2018-01-01

    Bioelectrical impedance analysis (BIA) is often used to estimate total body water (TBW), intracellular body water (ICW), extracellular body water (ECW), and body fat percentage (BF%). A common restriction for BIA analysis is abstinence from caffeine 12-h prior to testing. However, research has yet to determine whether the consumption of caffeine influences BIA testing results. The purpose of this study was to determine if the consumption of caffeine influences BIA-derived BF% and body water values in habitual caffeine users. Twenty apparently healthy males (26.6 ± 4.1 years) identified as habitual caffeine consumers (≥ one 95 mg serving per day ≥ four days per week) participated in this study. Participants came to the lab on three occasions, the first visit serving as the control (CON) with no supplementation. The remaining two visits were performed in a randomized double-blind, cross-over fashion. Participants consumed 200 mg of dextrose (PLA) or caffeine (CAF) in capsule form. During each visit, seven multi-frequency BIA measurements were conducted before (PRE) and after (15-min, 30-min, 45-min, 60-min, 75-min, 90-min) consumption. Repeated measures ANOVA revealed BF% for CAF was lower than the CON and PLA conditions at PRE and 15-min ( p  < 0.001, p  = 0.004), but not statistically significant for the remaining time points (i.e., 30-, 45-, 60-, 75-, and 90-min). However, the effect size (ES) of the BF% differences were trivial. The CON, PLA, and CAF conditions had higher PRE ICW values than their associated post time points (i.e., 15-, 30-, 45-, 60-, 75-, and 90-min). Similar to BF%, ES of the mean differences for ICW were trivial. No other differences were observed. Caffeine consumption in habitual users produced trivial changes in TBW, ECW, ICW, or BF%. Therefore, the pre-testing guidelines for caffeine consumption may not be necessary in habitual caffeine consumers.

  9. Chemical removal of necrotic periodontal ligament on delayed replanted teeth by sodium hypochlorite: morphological analysis and microhardness indentation test of cementum.

    PubMed

    Bai, J; Qin, M; Zhao, Y-M; Huang, M-W; Ji, A-P

    2016-04-01

    To compare the efficacy of sodium hypochlorite (NaOCl) used at different concentrations and working times for removing necrotic periodontal ligament (PDL) from delayed replanted teeth and to observe the effects of NaOCl on surface structure and microhardness of cementum. A total of 88 healthy premolars with a single root extracted for orthodontic purposes were selected and kept dry at room temperature for 1 h. The teeth were divided into 11 groups: group 1 (control): roots were untreated; group 2: necrotic PDL was removed with gauze; groups 3-11: teeth were immersed in NaOCl at different concentrations (1, 2.5 and 5.25%) and for different working times (5, 10 and 15 min). The specimens in each group were inspected separately for cementum integrity and the presence of PDL remnants by histomorphometric analysis, confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). Another 14 healthy premolars with roots divided into two pieces were selected for Vickers microhardness indentation tests before and after NaOCl treatment. The data were analysed statistically using Wilcoxon signed-rank test of two-related samples (P = 0.05). In teeth treated with 1% NaOCl for 15 min or 5.25% NaOCl for 5 min, the cementum remained morphologically intact without cracks, and PDL remnants were absent. In the 1% NaOCl for 15 min group, the microstructure of cementum was arranged more regularly, as observed ×8000 magnification by SEM. Teeth in each of the other groups displayed cementum damage and/or the presence of PDL remnants. Microhardness tests revealed that treatment with 1% NaOCl for 15 min or 5.25% NaOCl for 5 min significantly decreased microhardness of root cementum (P < 0.05). Use of either 1% NaOCl for 15 min or 5.25% NaOCl for 5 min was effective at removing necrotic PDL from the delayed replanted teeth whilst having a minimal influence on cementum integrity. However, 1% NaOCl for 15 min was less damaging to cementum. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  10. Fully automated spectrometric protocols for determination of antioxidant activity: advantages and disadvantages.

    PubMed

    Sochor, Jiri; Ryvolova, Marketa; Krystofova, Olga; Salas, Petr; Hubalek, Jaromir; Adam, Vojtech; Trnkova, Libuse; Havel, Ladislav; Beklova, Miroslava; Zehnalek, Josef; Provaznik, Ivo; Kizek, Rene

    2010-11-29

    The aim of this study was to describe behaviour, kinetics, time courses and limitations of the six different fully automated spectrometric methods--DPPH, TEAC, FRAP, DMPD, Free Radicals and Blue CrO5. Absorption curves were measured and absorbance maxima were found. All methods were calibrated using the standard compounds Trolox® and/or gallic acid. Calibration curves were determined (relative standard deviation was within the range from 1.5 to 2.5%). The obtained characteristics were compared and discussed. Moreover, the data obtained were applied to optimize and to automate all mentioned protocols. Automatic analyzer allowed us to analyse simultaneously larger set of samples, to decrease the measurement time, to eliminate the errors and to provide data of higher quality in comparison to manual analysis. The total time of analysis for one sample was decreased to 10 min for all six methods. In contrary, the total time of manual spectrometric determination was approximately 120 min. The obtained data provided good correlations between studied methods (R=0.97-0.99).

  11. Desflurane Allows for a Faster Emergence When Compared to Sevoflurane without Affecting the Baseline Cognitive Recovery Time.

    PubMed

    Werner, Joseph G; Castellon-Larios, Karina; Thongrong, Cattleya; Knudsen, Bodo E; Lowery, Deborah S; Antor, Maria A; Bergese, Sergio Daniel

    2015-01-01

    We compared the effect of desflurane and sevoflurane on anesthesia recovery time in patients undergoing urological cystoscopic surgery. The Short Orientation-Memory-Concentration Test (SOMCT) measured and compared cognitive impairment between groups and coughing was assessed throughout the anesthetic. This investigation included 75 ambulatory patients. Patients were randomized to receive either desflurane or sevoflurane. Inhalational anesthetics were discontinued after removal of the cystoscope and once repositioning of the patient was final. Coughing assessment and awakening time from anesthesia were assessed by a blinded observer. Statistical analysis was performed by using t-test for parametric variables and Mann-Whitney U test for non-parametric variables. The primary endpoint, mean time to eye-opening, was 5.0 ± 2.5 min for desflurane and 7.9 ± 4.1 min for sevoflurane (p < 0.001). There were no significant differences in time to SOMCT recovery (p = 0.109), overall time spent in the post-anesthesia care unit (PACU) (p = 0.924) or time to discharge (p = 0.363). Median time until readiness for discharge was 9 min in the desflurane group, while the sevoflurane group had a median time of 20 min (p = 0.020). The overall incidence of coughing during the perioperative period was significantly higher in the desflurane (p = 0.030). We re-confirmed that patients receiving desflurane had a faster emergence and met the criteria to be discharged from the PACU earlier. No difference was found in time to return to baseline cognition between desflurane and sevoflurane.

  12. Is liver SUV stable over time in ¹⁸F-FDG PET imaging?

    PubMed

    Laffon, Eric; Adhoute, Xavier; de Clermont, Henri; Marthan, Roger

    2011-12-01

    This work investigated whether (18)F-FDG PET standardized uptake value (SUV) is stable over time in the normal human liver. The SUV-versus-time curve, SUV(t), of (18)F-FDG in the normal human liver was derived from a kinetic model analysis. This derivation involved mean values of (18)F-FDG liver metabolism that were obtained from a patient series (n = 11), and a noninvasive population-based input function was used in each individual. Mean values (±95% reliability limits) of the (18)F-FDG uptake and release rate constant and of the fraction of free tracer in blood and interstitial volume were as follows: K = 0.0119 mL·min(-1)·mL(-1) (±0.0012), k(R) = 0.0065·min(-1) (±0.0009), and F = 0.21 mL·mL(-1) (±0.11), respectively. SUV(t) (corrected for (18)F physical decay) was derived from these mean values, showing that it smoothly peaks at 75-80 min on average after injection and that it is within 5% of the peak value between 50 and 110 min after injection. In the normal human liver, decay-corrected SUV(t) remains nearly constant (with a reasonable ±2.5% relative measurement uncertainty) if the time delay between tracer injection and PET acquisition is in the range of 50-110 min. In current clinical practice, the findings suggest that SUV of the normal liver can be used for comparison with SUV of suspected malignant lesions, if comparison is made within this time range.

  13. Melamine detection in infant formula powder using near- and mid-infrared spectroscopy.

    PubMed

    Mauer, Lisa J; Chernyshova, Alona A; Hiatt, Ashley; Deering, Amanda; Davis, Reeta

    2009-05-27

    Near- and mid-infrared spectroscopy methods (NIR, FTIR-ATR, FTIR-DRIFT) were evaluated for the detection and quantification of melamine in infant formula powder. Partial least-squares (PLS) models were established for correlating spectral data to melamine concentration: R(2) > 0.99, RMSECV ≤ 0.9, and RPD ≥ 12. Factorization analysis of spectra was able to differentiate unadulterated infant formula powder from samples containing 1 ppm melamine with no misclassifications, a confidence level of 99.99%, and selectivity > 2. These nondestructive methods require little or no sample preparation. The NIR method has an assay time of 1 min, and a 2 min total time to detection. The FTIR methods require up to 5 min for melamine detection. Therefore, NIR and FTIR methods enable rapid detection of 1 ppm melamine in infant formula powder.

  14. Effects of TEA·HCl hardening accelerator on the workability of cement-based materials

    NASA Astrophysics Data System (ADS)

    Pan, Wenhao; Ding, Zhaoyang; Chen, Yanwen

    2017-03-01

    The aim of the test is to research the influence rules of TEA·HCl on the workability of cement paste and concrete. Based on the features of the new hardening accelerator, an experimental analysis system were established through different dosages of hardening accelerator, and the feasibility of such accelerator to satisfy the need of practical engineering was verified. The results show that adding of the hardening accelerator can accelerate the cement hydration, and what’s more, when the dosage was 0.04%, the setting time was the shortest while the initial setting time and final setting time were 130 min and 180 min, respectively. The initial fluidity of cement paste of adding accelerator was roughly equivalent compared with that of blank. After 30 min, fluidity loss would decrease with the dosage increasing, but fluidity may increase. The application of the hardening accelerator can make the early workability of concrete enhance, especially the slump loss of 30 min can improve more significantly. The bleeding rate of concrete significantly decreases after adding TEA·HCl. The conclusion is that the new hardening accelerator can meet the need of the workability of cement-based materials in the optimum dosage range.

  15. Decreasing triage time: effects of implementing a step-wise ESI algorithm in an EHR.

    PubMed

    Villa, Stephen; Weber, Ellen J; Polevoi, Steven; Fee, Christopher; Maruoka, Andrew; Quon, Tina

    2018-06-01

    To determine if adapting a widely-used triage scale into a computerized algorithm in an electronic health record (EHR) shortens emergency department (ED) triage time. Before-and-after quasi-experimental study. Urban, tertiary care hospital ED. Consecutive adult patient visits between July 2011 and June 2013. A step-wise algorithm, based on the Emergency Severity Index (ESI-5) was programmed into the triage module of a commercial EHR. Duration of triage (triage interval) for all patients and change in percentage of high acuity patients (ESI 1 and 2) completing triage within 15 min, 12 months before-and-after implementation of the algorithm. Multivariable analysis adjusted for confounders; interrupted time series demonstrated effects over time. Secondary outcomes examined quality metrics and patient flow. About 32 546 patient visits before and 33 032 after the intervention were included. Post-intervention patients were slightly older, census was higher and admission rate slightly increased. Median triage interval was 5.92 min (interquartile ranges, IQR 4.2-8.73) before and 2.8 min (IQR 1.88-4.23) after the intervention (P < 0.001). Adjusted mean triage interval decreased 3.4 min (95% CI: -3.6, -3.2). The proportion of high acuity patients completing triage within 15 min increased from 63.9% (95% CI 62.5, 65.2%) to 75.0% (95% CI 73.8, 76.1). Monthly time series demonstrated immediate and sustained improvement following the intervention. Return visits within 72 h and door-to-balloon time were unchanged. Total length of stay was similar. The computerized triage scale improved speed of triage, allowing more high acuity patients to be seen within recommended timeframes, without notable impact on quality.

  16. ST-Segment Analysis Using Wireless Technology in Acute Myocardial Infarction (STAT-MI) trial.

    PubMed

    Dhruva, Vivek N; Abdelhadi, Samir I; Anis, Ather; Gluckman, William; Hom, David; Dougan, William; Kaluski, Edo; Haider, Bunyad; Klapholz, Marc

    2007-08-07

    Our goal was to examine the effects of implementing a fully automated wireless network to reduce door-to-intervention times (D2I) in ST-segment elevation myocardial infarction (STEMI). Wireless technologies used to transmit prehospital electrocardiograms (ECGs) have helped to decrease D2I times but have unrealized potential. A fully automated wireless network that facilitates simultaneous 12-lead ECG transmission from emergency medical services (EMS) personnel in the field to the emergency department (ED) and offsite cardiologists via smartphones was developed. The system is composed of preconfigured Bluetooth devices, preprogrammed receiving/transmitting stations, dedicated e-mail servers, and smartphones. The network facilitates direct communication between offsite cardiologists and EMS personnel, allowing for patient triage directly to the cardiac catheterization laboratory from the field. Demographic, laboratory, and time interval data were prospectively collected and compared with calendar year 2005 data. From June to December 2006, 80 ECGs with suspected STEMI were transmitted via the network. Twenty patients with ECGs consistent with STEMI were triaged to the catheterization laboratory. Improvement was seen in mean door-to-cardiologist notification (-14.6 vs. 61.4 min, p < 0.001), door-to-arterial access (47.6 vs. 108.1 min, p < 0.001), time-to-first angiographic injection (52.8 vs. 119.2 min, p < 0.001), and D2I times (80.1 vs. 145.6 min, p < 0.001) compared with 2005 data. A fully automated wireless network that transmits ECGs simultaneously to the ED and offsite cardiologists for the early evaluation and triage of patients with suspected STEMI can decrease D2I times to <90 min and has the potential to be broadly applied in clinical practice.

  17. Postactivation Potentation Effects From Accommodating Resistance Combined With Heavy Back Squats on Short Sprint Performance.

    PubMed

    Wyland, Timothy P; Van Dorin, Joshua D; Reyes, G Francis Cisco

    2015-11-01

    Applying accommodating resistance combined with isoinertial resistance has been demonstrated to be effective in improving neuromuscular attributes important for sport performance. The main purpose of this study was to determine whether short sprints can be acutely enhanced after several sets of back squats with or without accommodating resistance. Twenty recreationally resistance-trained males (age: 23.3 ± 4.4 years; height: 178.9 ± 6.5 cm; weight: 88.3 ± 10.8 kg) performed pre-post testing on 9.1-m sprint time. Three different interventions were implemented in randomized order between pre-post 9.1-m sprints. On 3 separate days, subjects either sat for 5 minutes (CTRL), performed 5 sets of 3 repetitions at 85% of their 1 repetition maximum (1RM) with isoinertial load (STND), or performed 5 sets of 3 repetitions at 85% of their 1RM, with 30% of the total resistance coming from elastic band tension (BAND) between pre-post 9.1-m sprint testing. Posttesting for 9.1-m sprint time occurred immediately after the last set of squats (Post-Immediate) and on every minute for 4 minutes after the last set of squats (Post-1min, Post-2min, Post-3min, and Post-4min). Repeated-measures analysis of variance statistical analyses revealed no significant changes in sprint time across posttesting times during the CTRL and STND condition. During the BAND condition, sprint time significantly decreased from Post-Immediate to Post-4min (p = 0.002). The uniqueness of accommodating resistance could create an optimal postactivation potentiation effect to increase neuromuscular performance. Coaches and athletes can implement heavy accommodating resistance exercises to their warm-up when improving acute sprint time is desired.

  18. Inference and analysis of xenon outflow curves under multi-pulse injection in two-dimensional chromatography.

    PubMed

    Shu-Jiang, Liu; Zhan-Ying, Chen; Yin-Zhong, Chang; Shi-Lian, Wang; Qi, Li; Yuan-Qing, Fan

    2013-10-11

    Multidimensional gas chromatography is widely applied to atmospheric xenon monitoring for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). To improve the capability for xenon sampling from the atmosphere, sampling techniques have been investigated in detail. The sampling techniques are designed by xenon outflow curves which are influenced by many factors, and the injecting condition is one of the key factors that could influence the xenon outflow curves. In this paper, the xenon outflow curves of single-pulse injection in two-dimensional gas chromatography has been tested and fitted as a function of exponential modified Gaussian distribution. An inference formula of the xenon outflow curve for six-pulse injection is derived, and the inference formula is also tested to compare with its fitting formula of the xenon outflow curve. As a result, the curves of both the one-pulse and six-pulse injections obey the exponential modified Gaussian distribution when the temperature of the activated carbon column's temperature is 26°C and the flow rate of the carrier gas is 35.6mLmin(-1). The retention time of the xenon peak for one-pulse injection is 215min, and the peak width is 138min. For the six-pulse injection, however, the retention time is delayed to 255min, and the peak width broadens to 222min. According to the inferred formula of the xenon outflow curve for the six-pulse injection, the inferred retention time is 243min, the relative deviation of the retention time is 4.7%, and the inferred peak width is 225min, with a relative deviation of 1.3%. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Operational Efficiency and Productivity Improvement Initiatives in a Large Cardiac Catheterization Laboratory.

    PubMed

    Reed, Grant W; Hantz, Scott; Cunningham, Rebecca; Krishnaswamy, Amar; Ellis, Stephen G; Khot, Umesh; Rak, Joe; Kapadia, Samir R

    2018-02-26

    This study sought to report outcomes from an efficiency improvement project in a large cardiac cath lab. Operational inefficiencies are common in the cath lab, yet solutions are challenging. A detailed report describing and providing solutions for these inefficiencies may be valuable in guiding improvements in productivity. In this observational study, the authors report metrics of efficiency before and after a cath lab quality improvement program in June 2014. Main outcomes included lab room start times, room turnaround times, laboratory use, and employee satisfaction. Time series analysis was used to assess trend over time. Chi-square testing and analysis of variance were used to assess change before and after the initiative. The principal changes included implementation of a pyramidal nursing schedule, increased use of an electronic scheduling system, and increased utilization of a preparation and recovery area. Comparing before with after the program, start times improved an average of 17 min, and on-time starts improved from 61.8% to 81.7% (p = 0.0024). Turnaround times improved from 20.5 min to 16.4 min (trend p < 0.0001), and the proportion of days at full lab utilization improved from 7.7% to 77.3% (p < 0.00001). There were no increases in overtime, night, or weekend cases. There was a reduction in full time employees from 36.1 in 2013 to 29.6 in 2016, with an improvement in employee satisfaction. A systematic approach to reducing inefficiencies can improve cath lab start times, turnaround times, and overall productivity. This knowledge may be helpful in assisting other cath labs in similar efficiency improvement initiatives. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. 12 min/week of high-intensity interval training reduces aortic reservoir pressure in individuals with metabolic syndrome: a randomized trial.

    PubMed

    Ramos, Joyce S; Dalleck, Lance C; Ramos, Maximiano V; Borrani, Fabio; Roberts, Llion; Gomersall, Sjaan; Beetham, Kassia S; Dias, Katrin A; Keating, Shelley E; Fassett, Robert G; Sharman, James E; Coombes, Jeff S

    2016-10-01

    Decreased aortic reservoir function leads to a rise in aortic reservoir pressure that is an independent predictor of cardiovascular events. Although there is evidence that high-intensity interval training (HIIT) would be useful to improve aortic reservoir pressure, the optimal dose of high-intensity exercise to improve aortic reservoir function has yet to be investigated. Therefore, this study compared the effect of different volumes of HIIT and moderate-intensity continuous training (MICT) on aortic reservoir pressure in participants with the metabolic syndrome (MetS). Fifty individuals with MetS were randomized into one of the following 16-week training programs: MICT [n = 17, 30 min at 60-70% peak heart rate (HRpeak), five times/week]; 4 × 4-min high-intensity interval training (4HIIT) (n = 15, 4 × 4 min bouts at 85-95% HRpeak, interspersed with 3 min of active recovery at 50-70% HRpeak, three times/week); and 1 × 4-min high-intensity interval training (1HIIT) (n = 18, 1 × 4 min bout at 85-95% HRpeak, three times/week). Aortic reservoir pressure was calculated from radial applanation tonometry. Although not statistically significant, there was a trend for a small-to-medium group × time interaction effect on aortic reservoir pressure, indicating a positive adaptation following 1HIIT compared with 4HIIT and MICT [F (2,46) = 2.9, P = 0.07, η = 0.06]. This is supported by our within-group analysis wherein only 1HIIT significantly decreased aortic reservoir pressure from pre to postintervention (pre-post: 1HIIT 33 ± 16 to 31 ± 13, P = 0.03; MICT 29 ± 9-28 ± 8, P = 0.78; 4HIIT 28 ± 10-30 ± 9 mmHg, P = 0.10). Three sessions of 4 min of high-intensity exercise per week (12 min/week) was sufficient to improve aortic reservoir pressure, and thus may be a time-efficient exercise modality for reducing cardiovascular risk in individuals with MetS.

  1. A Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form.

    PubMed

    Darsazan, Bahar; Shafaati, Alireza; Mortazavi, Seyed Alireza; Zarghi, Afshin

    2017-01-01

    A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C 18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 mL/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a retention time of 5.8 ± 0.01 min. No interferences were observed from its stress degradation products. The method was validated according to the international guidelines. Linear regression analysis of data for the calibration plot showed a linear relationship between peak area and concentration over the range of 0.5-16 μg/mL; the regression coefficient was 0.9999and the linear regression equation was y = 24844x-2941.3. The detection (LOD) and quantification (LOQ) limits were 0.12 and 0.35 μg/mL, respectively. The results proved the method was fast (analysis time less than 7 min), precise, reproducible, and accurate for analysis of ADV over a wide range of concentration. The proposed specific method was used for routine quantification of ADV in pharmaceutical bulk and a tablet dosage form.

  2. High-throughput analysis of bergamot essential oil by fast solid-phase microextraction-capillary gas chromatography-flame ionization detection.

    PubMed

    Tranchida, Peter Quinto; Presti, Maria Lo; Costa, Rosaria; Dugo, Paola; Dugo, Giovanni; Mondello, Luigi

    2006-01-20

    The advantages of using a narrow-bore column in headspace solid-phase microextraction-gas chromatographic (HS-SPME-GC) analysis are investigated. An automated rapid HS-SPME-GC method for the determination of volatile compounds in a complex sample (bergamot essential oil) was developed. A low-capacity (7 microm) SPME fibre was employed, enabling a short equilibration time (15 min). The absorbed volatile compounds were then separated in 12.5 min on a 10 m x 0.1 mm I.D. capillary. The fast GC method was characterized by relatively moderate GC parameters (head pressure: 173 kPa; temperature program rate: 12 degrees C/min). The employment of the low-capacity fibre also suited the reduced sample capacity of the capillary employed, hence column overloading was avoided. Analytical repeatibility was determined in terms of retention times (maximum RSD: 0.32%) and peak areas (maximum RSD: 9.80%). The results obtained were compared to those derived from a conventional HS-SPME-GC (a 30 microm SPME fibre and 0.25 mm I.D. capillary were used) application on the same sample. In this respect, a great reduction of analytical time was obtained both with regard to the conventional SPME equilibration and GC run times, which both required 50 min. Peak resolution was altogether comparable in both applications. Although a slight loss in terms of sensitivity was observed in the rapid approach (generally within the 25-50% range), this did not impair the detection of all peaks of interest. Finally, the selectivities of the 30 and 7 microm fibres were evaluated and, as expected, these were in good agreement.

  3. Technical note: Improving modeling of coagulation, curd firming, and syneresis of sheep milk.

    PubMed

    Cipolat-Gotet, Claudio; Pazzola, Michele; Ferragina, Alessandro; Cecchinato, Alessio; Dettori, Maria L; Vacca, Giuseppe M

    2018-04-18

    The importance of milk coagulation properties for milk processing, cheese yield, and quality is widely recognized. The use of traditional coagulation traits presents several limitations for testing bovine milk and even more for sheep milk, due to its rapid coagulation and curd firming, and early syneresis of coagulum. The aim of this technical note is to test and improve model fitting for assessing coagulation, curd firming, and syneresis of sheep milk. Using milk samples from 87 Sarda ewes, we performed in duplicate lactodynamographic testing. On each of the 174 analyzed milk aliquots, using 180 observations from each aliquot (one every 15 s for 45 min after rennet addition), we compared 4 different curd firming models as a function of time (CF t , mm) using a nonlinear procedure. The most accurate and informative results were observed using a modified 4-parameter model, structured as follows: [Formula: see text] , where t is time, RCT eq (min) is the gelation time, CF P (mm) is the potential asymptotical CF at an infinite time, k CF (%/min) is the curd firming rate constant, and k SR (%/min) is the curd syneresis rate constant. To avoid nonconvergence and computational problems due to interrelations among the equation parameters, CF P was preliminarily defined as a function of maximum observed curd firmness (CF max , mm) recorded during the analysis. For this model, all the modeling equations of individual sheep milk aliquots were converging, with a negligible standard error of the estimates (coefficient of determination >0.99 for all individual sample equations). Repeatability of the modeled parameters was acceptable, also in the presence of curd syneresis during the lactodynamographic analysis. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  4. Physiological responses and external validity of a new setting for taekwondo combat simulation.

    PubMed

    Hausen, Matheus; Soares, Pedro Paulo; Araújo, Marcus Paulo; Porto, Flávia; Franchini, Emerson; Bridge, Craig Alan; Gurgel, Jonas

    2017-01-01

    Combat simulations have served as an alternative framework to study the cardiorespiratory demands of the activity in combat sports, but this setting imposes rule-restrictions that may compromise the competitiveness of the bouts. The aim of this study was to assess the cardiorespiratory responses to a full-contact taekwondo combat simulation using a safe and externally valid competitive setting. Twelve male national level taekwondo athletes visited the laboratory on two separate occasions. On the first visit, anthropometric and running cardiopulmonary exercise assessments were performed. In the following two to seven days, participants performed a full-contact combat simulation, using a specifically designed gas analyser protector. Oxygen uptake ([Formula: see text]), heart rate (HR) and capillary blood lactate measurements ([La-]) were obtained. Time-motion analysis was performed to compare activity profile. The simulation yielded broadly comparable activity profiles to those performed in competition, a mean [Formula: see text] of 36.6 ± 3.9 ml.kg-1.min-1 (73 ± 6% [Formula: see text]) and mean HR of 177 ± 10 beats.min-1 (93 ± 5% HRPEAK). A peak [Formula: see text] of 44.8 ± 5.0 ml.kg-1.min-1 (89 ± 5% [Formula: see text]), a peak heart rate of 190 ± 13 beats.min-1 (98 ± 3% HRmax) and peak [La-] of 12.3 ± 2.9 mmol.L-1 was elicited by the bouts. Regarding time-motion analysis, combat simulation presented a similar exchange time, a shorter preparation time and a longer exchange-preparation ratio. Taekwondo combats capturing the full-contact competitive elements of a bout elicit moderate to high cardiorespiratory demands on the competitors. These data are valuable to assist preparatory strategies within the sport.

  5. Physiological responses and external validity of a new setting for taekwondo combat simulation

    PubMed Central

    2017-01-01

    Combat simulations have served as an alternative framework to study the cardiorespiratory demands of the activity in combat sports, but this setting imposes rule-restrictions that may compromise the competitiveness of the bouts. The aim of this study was to assess the cardiorespiratory responses to a full-contact taekwondo combat simulation using a safe and externally valid competitive setting. Twelve male national level taekwondo athletes visited the laboratory on two separate occasions. On the first visit, anthropometric and running cardiopulmonary exercise assessments were performed. In the following two to seven days, participants performed a full-contact combat simulation, using a specifically designed gas analyser protector. Oxygen uptake (V˙O2), heart rate (HR) and capillary blood lactate measurements ([La-]) were obtained. Time-motion analysis was performed to compare activity profile. The simulation yielded broadly comparable activity profiles to those performed in competition, a mean V˙O2 of 36.6 ± 3.9 ml.kg-1.min-1 (73 ± 6% V˙O2PEAK) and mean HR of 177 ± 10 beats.min-1 (93 ± 5% HRPEAK). A peak V˙O2 of 44.8 ± 5.0 ml.kg-1.min-1 (89 ± 5% V˙O2PEAK), a peak heart rate of 190 ± 13 beats.min-1 (98 ± 3% HRmax) and peak [La-] of 12.3 ± 2.9 mmol.L–1 was elicited by the bouts. Regarding time-motion analysis, combat simulation presented a similar exchange time, a shorter preparation time and a longer exchange-preparation ratio. Taekwondo combats capturing the full-contact competitive elements of a bout elicit moderate to high cardiorespiratory demands on the competitors. These data are valuable to assist preparatory strategies within the sport. PMID:28158252

  6. Investigation of endothelial function by pulse contour analysis: a protocol for drug administration and timing of pulse contour assessment

    PubMed Central

    Gordon, Sarah E; Cartwright, Neil; Griffiths, Mark J D

    2009-01-01

    AIMS Pulse contour analysis (PCA) obtained by finger photoplethysmography produces a digital volume pulse (DVP) including an inflection point in its down-slope. The reflection index (RI: ratio of the inflection point height over the maximal DVP) is responsive to vasodilatation. We aimed to optimize the drug dose and time interval for assessing endothelial function using PCA in healthy volunteers and patients with severe coronary artery disease. METHODS Time and dose to RI response relationships were constructed in 16 volunteers and nine patients to inhaled salbutamol (100–400 µg) or sublingual nitroglycerin (NTG; 25–400 µg). RESULTS For the volunteers, the time to maximum RI response to inhaled salbutamol and sublingual NTG was 10.73 ± 0.41 and 3.66 ± 0.21 min, respectively. A plateau in the RI response to salbutamol occurred between 5 and 15 min after inhalation and results were averaged over this period. A dose-dependent response was observed to inhaled salbutamol and sublingual NTG (P= 0.05 and P < 0.001 by repeated-measures anova, respectively) in healthy volunteers. By contrast, in patients with severe coronary artery disease inhaled salbutamol (100–400 µg) did not cause a significant change in RI. CONCLUSIONS In healthy volunteers the RI response to inhaled salbutamol (100–200 µg) averaged over 5–15 min after administration may be used to investigate endothelial function by PCA. The response to sublingual NTG (50 µg) should be determined at 4 min. This technique may not be suitable for the assessment of endothelial function in subjects with extensive coronary artery disease owing to the small responses observed and potential confounding effect of vasoactive medication. PMID:19843066

  7. Development, optimization, validation and application of faster gas chromatography - flame ionization detector method for the analysis of total petroleum hydrocarbons in contaminated soils.

    PubMed

    Zubair, Abdulrazaq; Pappoe, Michael; James, Lesley A; Hawboldt, Kelly

    2015-12-18

    This paper presents an important new approach to improving the timeliness of Total Petroleum Hydrocarbon (TPH) analysis in the soil by Gas Chromatography - Flame Ionization Detector (GC-FID) using the CCME Canada-Wide Standard reference method. The Canada-Wide Standard (CWS) method is used for the analysis of petroleum hydrocarbon compounds across Canada. However, inter-laboratory application of this method for the analysis of TPH in the soil has often shown considerable variability in the results. This could be due, in part, to the different gas chromatography (GC) conditions, other steps involved in the method, as well as the soil properties. In addition, there are differences in the interpretation of the GC results, which impacts the determination of the effectiveness of remediation at hydrocarbon-contaminated sites. In this work, multivariate experimental design approach was used to develop and validate the analytical method for a faster quantitative analysis of TPH in (contaminated) soil. A fractional factorial design (fFD) was used to screen six factors to identify the most significant factors impacting the analysis. These factors included: injection volume (μL), injection temperature (°C), oven program (°C/min), detector temperature (°C), carrier gas flow rate (mL/min) and solvent ratio (v/v hexane/dichloromethane). The most important factors (carrier gas flow rate and oven program) were then optimized using a central composite response surface design. Robustness testing and validation of model compares favourably with the experimental results with percentage difference of 2.78% for the analysis time. This research successfully reduced the method's standard analytical time from 20 to 8min with all the carbon fractions eluting. The method was successfully applied for fast TPH analysis of Bunker C oil contaminated soil. A reduced analytical time would offer many benefits including an improved laboratory reporting times, and overall improved clean up efficiency. The method was successfully applied for the analysis of TPH of Bunker C oil in contaminated soil. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  8. Determination of volume-time curves for the right ventricle and its outflow tract for functional analyses.

    PubMed

    Gabbert, Dominik D; Entenmann, Andreas; Jerosch-Herold, Michael; Frettlöh, Felicitas; Hart, Christopher; Voges, Inga; Pham, Minh; Andrade, Ana; Pardun, Eileen; Wegner, P; Hansen, Traudel; Kramer, Hans-Heiner; Rickers, Carsten

    2013-12-01

    The determination of right ventricular volumes and function is of increasing interest for the postoperative care of patients with congenital heart defects. The presentation of volumetry data in terms of volume-time curves allows a comprehensive functional assessment. By using manual contour tracing, the generation of volume-time curves is exceedingly time-consuming. This study describes a fast and precise method for determining volume-time curves for the right ventricle and for the right ventricular outflow tract. The method applies contour detection and includes a feature for identifying the right ventricular outflow tract volume. The segregation of the outflow tract is performed by four-dimensional curved smooth boundary surfaces defined by prespecified anatomical landmarks. The comparison with manual contour tracing demonstrates that the method is accurate and improves the precision of the measurement. Compared to manual contour tracing the bias is <0.1% ± 4.1% (right ventricle) and -2.6% ± 20.0% (right ventricular outflow tract). The standard deviations of inter- and intraobserver variabilities for determining the volume of the right ventricular outflow tract are reduced to less than half the values of manual contour tracing. The time consumption per patient is reduced from 341 ± 80 min (right ventricle) and 56 ± 11 min (right ventricular outflow tract) using manual contour tracing to 46 ± 9 min for a combined analysis of right ventricle and right ventricular outflow tract. The analysis of volume-time curves for the right ventricle and its outflow tract discloses new evaluation methods in clinical routine and science. Copyright © 2013 Wiley Periodicals, Inc.

  9. Toxicogenomic response of Mycobacterium bovis BCG to peracetic acid and a comparative analysis of the M. bovis BCG response to three oxidative disinfectants.

    PubMed

    Nde, Chantal W; Toghrol, Freshteh; Jang, Hyeung-Jin; Bentley, William E

    2011-04-01

    Tuberculosis is a leading cause of death worldwide and infects thousands of Americans annually. Mycobacterium bovis causes tuberculosis in humans and several animal species. Peracetic acid is an approved tuberculocide in hospital and domestic environments. This study presents for the first time the transcriptomic changes in M. bovis BCG after treatment with 0.1 mM peracetic acid for 10 and 20 min. This study also presents for the first time a comparison among the transcriptomic responses of M. bovis BCG to three oxidative disinfectants: peracetic acid, sodium hypochlorite, and hydrogen peroxide after 10 min of treatment. Results indicate that arginine biosynthesis, virulence, and oxidative stress response genes were upregulated after both peracetic acid treatment times. Three DNA repair genes were downregulated after 10 and 20 min and cell wall component genes were upregulated after 20 min. The devR-devS signal transduction system was upregulated after 10 min, suggesting a role in the protection against peracetic acid treatment. Results also suggest that peracetic acid and sodium hypochlorite both induce the expression of the ctpF gene which is upregulated in hypoxic environments. Further, this study reveals that in M. bovis BCG, hydrogen peroxide and peracetic acid both induce the expression of katG involved in oxidative stress response and the mbtD and mbtI genes involved in iron regulation/virulence.

  10. Global statistical maps of extreme-event magnetic observatory 1 min first differences in horizontal intensity

    USGS Publications Warehouse

    Love, Jeffrey J.; Coisson, Pierdavide; Pulkkinen, Antti

    2016-01-01

    Analysis is made of the long-term statistics of three different measures of ground level, storm time geomagnetic activity: instantaneous 1 min first differences in horizontal intensity ΔBh, the root-mean-square of 10 consecutive 1 min differences S, and the ramp change R over 10 min. Geomagnetic latitude maps of the cumulative exceedances of these three quantities are constructed, giving the threshold (nT/min) for which activity within a 24 h period can be expected to occur once per year, decade, and century. Specifically, at geomagnetic 55°, we estimate once-per-century ΔBh, S, and R exceedances and a site-to-site, proportional, 1 standard deviation range [1 σ, lower and upper] to be, respectively, 1000, [690, 1450]; 500, [350, 720]; and 200, [140, 280] nT/min. At 40°, we estimate once-per-century ΔBh, S, and R exceedances and 1 σ values to be 200, [140, 290]; 100, [70, 140]; and 40, [30, 60] nT/min.

  11. Carbon isotopic analysis of atmospheric methane by isotope-ratio-monitoring gas chromatography-mass spectrometry

    NASA Technical Reports Server (NTRS)

    Merritt, Dawn A.; Hayes, J. M.; Des Marais, David J.

    1995-01-01

    Less than 15 min are required for the determination of delta C(sub PDB)-13 with a precision of 0.2 ppt(1 sigma, single measurement) in 5-mL samples of air containing CH4 at natural levels (1.7 ppm). An analytical system including a sample-introduction unit incorporating a preparative gas chromatograph (GC) column for separation of CH4 from N2, O2, and Ar is described. The 15-min procedure includes time for operation of that system, high-resolution chromatographic separation of the CH4, on-line combustion and purification of the products, and isotopic calibration. Analyses of standards demonstrate that systematic errors are absent and that there is no dependence of observed values of delta on sample size. For samples containing 100 ppm or more CH4, preconcentration is not required and the analysis time is less than 5 min. The system utilizes a commercially available, high-sensitivity isotope-ratio mass spectrometer. For optimal conditions of smaple handling and combustion, performance of the system is within a factor of 2 of the shot-noise limit. The potential exists therefore for analysis of samples as small as 15 pmol CH4 with a standard deviation of less than 1 ppt.

  12. Focused microwave-assisted extraction combined with solid-phase microextraction and gas chromatography-mass spectrometry for the selective analysis of cocaine from coca leaves.

    PubMed

    Bieri, Stefan; Ilias, Yara; Bicchi, Carlo; Veuthey, Jean-Luc; Christen, Philippe

    2006-04-21

    An effective combination of focused microwave-assisted extraction (FMAE) with solid-phase microextraction (SPME) prior to gas chromatography (GC) is described for the selective extraction and quantitative analysis of cocaine from coca leaves (Erythroxylum coca). This approach required switching from an organic extraction solvent to an aqueous medium more compatible with SPME liquid sampling. SPME was performed in the direct immersion mode with a universal 100 microm polydimethylsiloxane (PDMS) coated fibre. Parameters influencing this extraction step, such as solution pH, sampling time and temperature are discussed. Furthermore, the overall extraction process takes into account the stability of cocaine in alkaline aqueous solutions at different temperatures. Cocaine degradation rate was determined by capillary electrophoresis using the short end injection procedure. In the selected extraction conditions, less than 5% of cocaine was degraded after 60 min. From a qualitative point of view, a significant gain in selectivity was obtained with the incorporation of SPME in the extraction procedure. As a consequence of SPME clean-up, shorter columns could be used and analysis time was reduced to 6 min compared to 35 min with conventional GC. Quantitative results led to a cocaine content of 0.70 +/- 0.04% in dry leaves (RSD <5%) which agreed with previous investigations.

  13. Impact of the Timing of Metoprolol Administration During STEMI on Infarct Size and Ventricular Function.

    PubMed

    García-Ruiz, Jose M; Fernández-Jiménez, Rodrigo; García-Alvarez, Ana; Pizarro, Gonzalo; Galán-Arriola, Carlos; Fernández-Friera, Leticia; Mateos, Alonso; Nuno-Ayala, Mario; Aguero, Jaume; Sánchez-González, Javier; García-Prieto, Jaime; López-Melgar, Beatriz; Martínez-Tenorio, Pedro; López-Martín, Gonzalo J; Macías, Angel; Pérez-Asenjo, Braulio; Cabrera, José A; Fernández-Ortiz, Antonio; Fuster, Valentín; Ibáñez, Borja

    2016-05-10

    Pre-reperfusion administration of intravenous (IV) metoprolol reduces infarct size in ST-segment elevation myocardial infarction (STEMI). This study sought to determine how this cardioprotective effect is influenced by the timing of metoprolol therapy having either a long or short metoprolol bolus-to-reperfusion interval. We performed a post hoc analysis of the METOCARD-CNIC (effect of METOprolol of CARDioproteCtioN during an acute myocardial InfarCtion) trial, which randomized anterior STEMI patients to IV metoprolol or control before mechanical reperfusion. Treated patients were divided into short- and long-interval groups, split by the median time from 15 mg metoprolol bolus to reperfusion. We also performed a controlled validation study in 51 pigs subjected to 45 min ischemia/reperfusion. Pigs were allocated to IV metoprolol with a long (-25 min) or short (-5 min) pre-perfusion interval, IV metoprolol post-reperfusion (+60 min), or IV vehicle. Cardiac magnetic resonance (CMR) was performed in the acute and chronic phases in both clinical and experimental settings. For 218 patients (105 receiving IV metoprolol), the median time from 15 mg metoprolol bolus to reperfusion was 53 min. Compared with patients in the short-interval group, those with longer metoprolol exposure had smaller infarcts (22.9 g vs. 28.1 g; p = 0.06) and higher left ventricular ejection fraction (LVEF) (48.3% vs. 43.9%; p = 0.019) on day 5 CMR. These differences occurred despite total ischemic time being significantly longer in the long-interval group (214 min vs. 160 min; p < 0.001). There was no between-group difference in the time from symptom onset to metoprolol bolus. In the animal study, the long-interval group (IV metoprolol 25 min before reperfusion) had the smallest infarcts (day 7 CMR) and highest long-term LVEF (day 45 CMR). In anterior STEMI patients undergoing primary angioplasty, the sooner IV metoprolol is administered in the course of infarction, the smaller the infarct and the higher the LVEF. These hypothesis-generating clinical data are supported by a dedicated experimental large animal study. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. A visual parallel-BCI speller based on the time-frequency coding strategy

    NASA Astrophysics Data System (ADS)

    Xu, Minpeng; Chen, Long; Zhang, Lixin; Qi, Hongzhi; Ma, Lan; Tang, Jiabei; Wan, Baikun; Ming, Dong

    2014-04-01

    Objective. Spelling is one of the most important issues in brain-computer interface (BCI) research. This paper is to develop a visual parallel-BCI speller system based on the time-frequency coding strategy in which the sub-speller switching among four simultaneously presented sub-spellers and the character selection are identified in a parallel mode. Approach. The parallel-BCI speller was constituted by four independent P300+SSVEP-B (P300 plus SSVEP blocking) spellers with different flicker frequencies, thereby all characters had a specific time-frequency code. To verify its effectiveness, 11 subjects were involved in the offline and online spellings. A classification strategy was designed to recognize the target character through jointly using the canonical correlation analysis and stepwise linear discriminant analysis. Main results. Online spellings showed that the proposed parallel-BCI speller had a high performance, reaching the highest information transfer rate of 67.4 bit min-1, with an average of 54.0 bit min-1 and 43.0 bit min-1 in the three rounds and five rounds, respectively. Significance. The results indicated that the proposed parallel-BCI could be effectively controlled by users with attention shifting fluently among the sub-spellers, and highly improved the BCI spelling performance.

  15. Ultrasound assisted extraction of polysaccharides from hazelnut skin.

    PubMed

    Yılmaz, Tuncay; Tavman, Şebnem

    2016-03-01

    In this study ultrasound assisted extraction (UAE) of polysaccharides from hazelnut skin has been studied. Optimum sonication time has been evaluated depending on responses such as amount of carbohydrate and dried sample and thermogravimetric analysis. Chemical and structural properties of extracted material have been determined by Fourier transform spectroscopy attenuated-total reflectance (FTIR-ATR) spectroscopy. Pretreated hazelnut skin powders were extracted in distilled water. Mixture was sonicated by ultrasonic processor probe for 15, 30, 45, 60, 90, and 120 min. The results of UAE showed that maximum ethanol insoluble extracts in 60 min and the highest dry matter content could be obtained in 120 min extraction. Although total carbohydrate content of ethanol insoluble dry extract decreased with time, total carbohydrate in ethanol soluble fraction increased. Polysaccharides extracted from hazelnut skin were assumed to be pectic polysaccharide according to the literature survey of FTIR analysis result. Application time of UAE has an important effect on extraction of polysaccharide from hazelnut skin. This affect could be summarized by enhancing extraction yield up to critical level. Decrease of the yield in ethanol insoluble part could be explained by polymer decomposition. Most suitable model was hyperbolic model by having the lowest root mean square error and the highest R(2) values. © The Author(s) 2015.

  16. "Personal best times in an olympic distance triathlon and a marathon predict an ironman race time for recreational female triathletes".

    PubMed

    Rüst, Christoph Alexander; Knechtle, Beat; Wirth, Andrea; Knechtle, Patrizia; Ellenrieder, Birte; Rosemann, Thomas; Lepers, Romuald

    2012-06-30

    "The aim of this study was to investigate whether the characteristics of anthropometry, training or previous performance were related to an Ironman race time in recreational female Ironman triathletes. These characteristics were correlated to an Ironman race time for 53 recreational female triathletes in order to determine the predictor variables, and so be able to predict an Ironman race time for future novice triathletes. In the bi-variate analysis, no anthropometric characteristic was related to race time. The weekly cycling kilometers (r = -0.35) and hours (r = -0.32), as well as the personal best time in an Olympic distance triathlon (r = 0.49) and in a marathon (r = 0.74) were related to an Ironman race time (< 0.05). Stepwise multiple regressions showed that both the personal best time in an Olympic distance triathlon ( P = 0.0453) and in a marathon (P = 0.0030) were the best predictors for the Ironman race time (n = 28, r² = 0.53). The race time in an Ironman triathlon might be partially predicted by the following equation (r² = 0.53, n = 28): Race time (min) = 186.3 + 1.595 × (personal best time in an Olympic distance triathlon, min) + 1.318 × (personal best time in a marathon, min) for recreational female Ironman triathletes."

  17. Association between maternal education and objectively measured physical activity and sedentary time in adolescents.

    PubMed

    Sherar, Lauren B; Griffin, Tom P; Ekelund, Ulf; Cooper, Ashley R; Esliger, Dale W; van Sluijs, Esther M F; Bo Andersen, Lars; Cardon, Greet; Davey, Rachel; Froberg, Karsten; Hallal, Pedro C; Janz, Kathleen F; Kordas, Katarzyna; Kriemler, Susi; Pate, Russell R; Puder, Jardena J; Sardinha, Luis B; Timperio, Anna F; Page, Angie S

    2016-06-01

    Investigating socioeconomic variation in physical activity (PA) and sedentary time is important as it may represent a pathway by which socioeconomic position (SEP) leads to ill health. Findings on the association between children's SEP and objectively assessed PA and/or sedentary time are mixed, and few studies have included international samples. Examine the associations between maternal education and adolescent's objectively assessed PA and sedentary time. This is an observational study of 12 770 adolescents (10-18 years) pooled from 10 studies from Europe, Australia, Brazil and the USA. Original PA data were collected between 1997 and 2009. The associations between maternal education and accelerometer variables were examined using robust multivariable regression, adjusted for a priori confounders (ie, body mass index, monitor wear time, season, age and sex) and regression coefficients combined across studies using random effects meta-analyses. Analyses were conducted in March 2014. Adolescents of university educated mothers spent more time sedentary (9.5 min/day, p=0.005) and less time in light activity (10 min/day, p<0.001) compared with adolescents of high school educated mothers. Pooled analysis across two studies from Brazil and Portugal (analysed separately because of the different coding of maternal education) showed that children of higher educated mothers (tertiary vs primary/secondary) spent less time in moderate to vigorous PA (MVPA) (6.6 min/day, p=0.001) and in light PA (39.2 min/day: p<0.001), and more time sedentary (45.9 min/day, p<0.001). Across a number of international samples, adolescents of mothers with lower education may not be at a disadvantage in terms of overall objectively measured PA. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. Preclinical Feasibility of a Technology Framework for MRI-guided Iliac Angioplasty

    PubMed Central

    Rube, Martin A.; Fernandez-Gutierrez, Fabiola; Cox, Benjamin F.; Holbrook, Andrew B.; Houston, J. Graeme; White, Richard D.; McLeod, Helen; Fatahi, Mahsa; Melzer, Andreas

    2015-01-01

    Purpose Interventional MRI has significant potential for image guidance of iliac angioplasty and related vascular procedures. A technology framework with in-room image display, control, communication and MRI-guided intervention techniques was designed and tested for its potential to provide safe, fast and efficient MRI-guided angioplasty of the iliac arteries. Methods A 1.5T MRI scanner was adapted for interactive imaging during endovascular procedures using new or modified interventional devices such as guidewires and catheters. A perfused vascular phantom was used for testing. Pre-, intra- and post-procedural visualization and measurement of vascular morphology and flow was implemented. A detailed analysis of X-Ray fluoroscopic angiography workflow was conducted and applied. Two interventional radiologists and one physician in training performed 39 procedures. All procedures were timed and analyzed. Results MRI-guided iliac angioplasty procedures were successfully performed with progressive adaptation of techniques and workflow. The workflow, setup and protocol enabled a reduction in table time for a dedicated MRI-guided procedure to 6 min 33 s with a mean procedure time of 9 min 2 s, comparable to the mean procedure time of 8 min 42 s for the standard X-Ray guided procedure. Conclusions MRI-guided iliac vascular interventions were found to be feasible and practical using this framework and optimized workflow. In particular the real-time flow analysis was found to be helpful for pre- and post-interventional assessments. Design optimization of the catheters and in vivo experiments are required before clinical evaluation. PMID:25102933

  19. Energy-Dispersive X-Ray Fluorescence Spectrometry: A Long Overdue Addition to the Chemistry Curriculum

    ERIC Educational Resources Information Center

    Palmer, Peter T.

    2011-01-01

    Portable Energy-Dispersive X-Ray Fluorescence (XRF) analyzers have undergone significant improvements over the past decade. Salient advantages of XRF for elemental analysis include minimal sample preparation, multielement analysis capabilities, detection limits in the low parts per million (ppm) range, and analysis times on the order of 1 min.…

  20. Time-Dependent Computed Tomographic Perfusion Thresholds for Patients With Acute Ischemic Stroke.

    PubMed

    d'Esterre, Christopher D; Boesen, Mari E; Ahn, Seong Hwan; Pordeli, Pooneh; Najm, Mohamed; Minhas, Priyanka; Davari, Paniz; Fainardi, Enrico; Rubiera, Marta; Khaw, Alexander V; Zini, Andrea; Frayne, Richard; Hill, Michael D; Demchuk, Andrew M; Sajobi, Tolulope T; Forkert, Nils D; Goyal, Mayank; Lee, Ting Y; Menon, Bijoy K

    2015-12-01

    Among patients with acute ischemic stroke, we determine computed tomographic perfusion (CTP) thresholds associated with follow-up infarction at different stroke onset-to-CTP and CTP-to-reperfusion times. Acute ischemic stroke patients with occlusion on computed tomographic angiography were acutely imaged with CTP. Noncontrast computed tomography and magnectic resonance diffusion-weighted imaging between 24 and 48 hours were used to delineate follow-up infarction. Reperfusion was assessed on conventional angiogram or 4-hour repeat computed tomographic angiography. Tmax, cerebral blood flow, and cerebral blood volume derived from delay-insensitive CTP postprocessing were analyzed using receiver-operator characteristic curves to derive optimal thresholds for combined patient data (pooled analysis) and individual patients (patient-level analysis) based on time from stroke onset-to-CTP and CTP-to-reperfusion. One-way ANOVA and locally weighted scatterplot smoothing regression was used to test whether the derived optimal CTP thresholds were different by time. One hundred and thirty-two patients were included. Tmax thresholds of >16.2 and >15.8 s and absolute cerebral blood flow thresholds of <8.9 and <7.4 mL·min(-1)·100 g(-1) were associated with infarct if reperfused <90 min from CTP with onset <180 min. The discriminative ability of cerebral blood volume was modest. No statistically significant relationship was noted between stroke onset-to-CTP time and the optimal CTP thresholds for all parameters based on discrete or continuous time analysis (P>0.05). A statistically significant relationship existed between CTP-to-reperfusion time and the optimal thresholds for cerebral blood flow (P<0.001; r=0.59 and 0.77 for gray and white matter, respectively) and Tmax (P<0.001; r=-0.68 and -0.60 for gray and white matter, respectively) parameters. Optimal CTP thresholds associated with follow-up infarction depend on time from imaging to reperfusion. © 2015 American Heart Association, Inc.

  1. Do players and staff sleep more during the pre- or competitive season of elite rugby league?

    PubMed

    Caia, Johnpaul; Scott, Tannath J; Halson, Shona L; Kelly, Vincent G

    2017-09-01

    This study establishes the sleep behaviour of players and staff during the pre- and competitive seasons of elite rugby league. For seven days during both the pre- and competitive seasons, seven rugby league players and nine full-time staff from one professional Australian rugby league club had their sleep monitored via wrist actigraphy and self-report sleep diaries. Two-way repeated measures analysis of variance determined differences between the pre- and competitive season in players and staff, with effect sizes (ES) used to interpret the practical magnitude of differences. Findings show an earlier bed time and wake time for players (-34 min, ES = 1.5; ±0.5 and -39 min, 2.1; ±0.5 respectively) and staff (-29 min, ES = 0.8; ±0.3 and -35 min, ES = 1.7; ±0.4 respectively) during pre-season when compared to the competitive season. Despite this, no differences were seen when considering the amount of time in bed, sleep duration or sleep efficiency obtained between the pre- and competitive seasons. Our results suggest that early morning training sessions scheduled during pre-season advances wake time in elite rugby league. However, both players and staff can aim to avoid reductions in sleep duration and sleep efficiency with subsequent adjustment of night time sleep patterns. This may be particularly pertinent for staff, who wake earlier than players during both the pre- and competitive seasons.

  2. [Time lag effect between poplar' s sap flow velocity and microclimate factors in agroforestry system in West Liaoning Province].

    PubMed

    Di, Sun; Guan, De-xin; Yuan, Feng-hui; Wang, An-zhi; Wu, Jia-bing

    2010-11-01

    By using Granier's thermal dissipation probe, the sap flow velocity of the poplars in agroforestry system in west Liaoning was continuously measured, and the microclimate factors were measured synchronously. Dislocation contrast method was applied to analyze the sap flow velocity and corresponding air temperature, air humidity, net radiation, and vapor pressure deficit to discuss the time lag effect between poplar' s sap flow velocity and microclimate factors on sunny days. It was found that the poplar's sap flow velocity advanced of air temperature, air humidity, and vapor pressure deficit, and lagged behind net radiation. The sap flow velocity in June, July, August, and September was advanced of 70, 30, 50, and 90 min to air temperature, of 80, 30, 40, and 90 min to air humidity, and of 90, 50, 70, and 120 min to vapor pressure deficit, but lagged behind 10, 10, 40, and 40 min to net radiation, respectively. The time lag time of net radiation was shorter than that of air temperature, air humidity, and vapor pressure. The regression analysis showed that in the cases the time lag effect was contained and not, the determination coefficients between comprehensive microclimate factor and poplar's sap flow velocity were 0.903 and 0.855, respectively, indicating that when the time lag effect was contained, the determination coefficient was ascended by 2.04%, and thus, the simulation accuracy of poplar's sap flow velocity was improved.

  3. Application of principal component analysis for the optimisation of lead(II) biosorption.

    PubMed

    Wajda, Łukasz; Duda-Chodak, Aleksandra; Tarko, Tomasz; Kamiński, Paweł

    2017-10-03

    Current study was focused on optimising lead(II) biosorption carried out by living cells of Arthrospira platensis using Principal Component Analysis. Various experimental conditions were considered: initial metal concentration (50 and 100 mg/l), solution pH (4.0, 4.5, 5.0, 5.5) and contact time (10, 20, 30, 40, 50 and 60 min) at constant rotary speed 200 rpm. It was found that when the biomass was separated from experimental solutions by the filtration, almost 50% of initial metal dose was removed by the filter paper. Moreover, pH was the most important parameter influencing examined processes. The Principal Component Analysis indicated that the most optimum conditions for lead(II) biosorption were metal initial concentration 100 mg/l, pH 4.5 and time 60 min. According to the analysis of the first component it might be stated that the lead(II) uptake increases in time. In overall, it was found to be useful for analysing data obtained in biosorption experiments and eliminating insignificant experimental conditions. Experimental data fitted Langmuir and Dubinin-Radushkevich models indicating that physical and chemical absorption take place at the same time. Further studies are necessary to verify how sorption-desorption cycles affect A. platensis cells.

  4. Process improvement to enhance existing stroke team activity toward more timely thrombolytic treatment.

    PubMed

    Cho, Han-Jin; Lee, Kyung Yul; Nam, Hyo Suk; Kim, Young Dae; Song, Tae-Jin; Jung, Yo Han; Choi, Hye-Yeon; Heo, Ji Hoe

    2014-10-01

    Process improvement (PI) is an approach for enhancing the existing quality improvement process by making changes while keeping the existing process. We have shown that implementation of a stroke code program using a computerized physician order entry system is effective in reducing the in-hospital time delay to thrombolysis in acute stroke patients. We investigated whether implementation of this PI could further reduce the time delays by continuous improvement of the existing process. After determining a key indicator [time interval from emergency department (ED) arrival to intravenous (IV) thrombolysis] and conducting data analysis, the target time from ED arrival to IV thrombolysis in acute stroke patients was set at 40 min. The key indicator was monitored continuously at a weekly stroke conference. The possible reasons for the delay were determined in cases for which IV thrombolysis was not administered within the target time and, where possible, the problems were corrected. The time intervals from ED arrival to the various evaluation steps and treatment before and after implementation of the PI were compared. The median time interval from ED arrival to IV thrombolysis in acute stroke patients was significantly reduced after implementation of the PI (from 63.5 to 45 min, p=0.001). The variation in the time interval was also reduced. A reduction in the evaluation time intervals was achieved after the PI [from 23 to 17 min for computed tomography scanning (p=0.003) and from 35 to 29 min for complete blood counts (p=0.006)]. PI is effective for continuous improvement of the existing process by reducing the time delays between ED arrival and IV thrombolysis in acute stroke patients.

  5. What provides a better value for your time? The use of relative value units to compare posterior segmental instrumentation of vertebral segments.

    PubMed

    Orr, R Douglas; Sodhi, Nipun; Dalton, Sarah E; Khlopas, Anton; Sultan, Assem A; Chughtai, Morad; Newman, Jared M; Savage, Jason; Mroz, Thomas E; Mont, Michael A

    2018-02-02

    Relative value units (RVUs) are a compensation model based on the effort required to provide a procedure or service to a patient. Thus, procedures that are more complex and require greater technical skill and aftercare, such as multilevel spine surgery, should provide greater physician compensation. However, there are limited data comparing RVUs with operative time. Therefore, this study aims to compare mean (1) operative times; (2) RVUs; and (3) RVU/min between posterior segmental instrumentation of 3-6, 7-12, and ≥13 vertebral segments, and to perform annual cost difference analysis. A total of 437 patients who underwent instrumentation of 3-6 segments (Cohort 1, current procedural terminology [CPT] code: 22842), 67 patients who had instrumentation of 7-12 segments (Cohort 2, CPT code: 22843), and 16 patients who had instrumentation of ≥13 segments (Cohort 3, CPT code: 22844) were identified from the National Surgical Quality Improvement Program (NSQIP) database. Mean operative times, RVUs, and RVU/min, as well as an annualized cost difference analysis, were calculated and compared using Student t test. This study received no funding from any party or entity. Cohort 1 had shorter mean operative times than Cohorts 2 and 3 (217 minutes vs. 325 minutes vs. 426 minutes, p<.05). Cohort 1 had a lower mean RVU than Cohorts 2 and 3 (12.6 vs. 13.4 vs. 16.4). Cohort 1 had a greater RVU/min than Cohorts 2 and 3 (0.08 vs. 0.05, p<.05; vs. 0.08 vs. 0.05, p>.05). A $112,432.12 annualized cost difference between Cohorts 1 and 2, a $176,744.76 difference between Cohorts 1 and 3, and a $64,312.55 difference between Cohorts 2 and 3 were calculated. The RVU/min takes into account not just the value provided but also the operative times required for highly complex cases. The RVU/min for fewer vertebral level instrumentation being greater (0.08 vs. 0.05), as well as the $177,000 annualized cost difference, indicates that compensation is not proportional to the added time, effort, and skill for more complex cases. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. [HPLC fingerprint chromatogram of Polygonum multiflorum from Guizhou].

    PubMed

    Li, Yan; Wang, Hui-Juan; Lin, Bing; Zhao, Zhi; Zhou, Ying

    2012-12-01

    To establish the fingerprint of Polygonum multiflorum from Guizhou and provide a standard for its quality control. HPLC analysis was performed on Agillent ZABAX-C18 (4.6 mm x 250 mm, 5 microm), gradient eluted composed of acetonitrile-0.4% water solution of phosphoric acid. Column temperature was set at 25 degrees C and the flow rate was 1 mL/min. The detection wavelength was 280 nm and the analysis time was 60 min. 9 common peaks were identified. The RSD of the relative retention time and the relative peak area were less than 3% in analyzing its precision, stability and repeatability of the common peaks, and the similarity of the 16 batches of sample was more than 0.9. The method is simple and reliable, and it can provide a standard and guidance for quality control of Polygonum multiflorum.

  7. Prime Time Light Exposures Do Not Seem to Improve Maximal Physical Performance in Male Elite Athletes, but Enhance End-Spurt Performance.

    PubMed

    Knaier, Raphael; Schäfer, Juliane; Rossmeissl, Anja; Klenk, Christopher; Hanssen, Henner; Höchsmann, Christoph; Cajochen, Christian; Schmidt-Trucksäss, Arno

    2017-01-01

    Many sports competitions take place during television prime time, a time of the day when many athletes have already exceeded their time of peak performance. We assessed the effect of different light exposure modalities on physical performance and melatonin levels in athletes during prime time. Seventy-two young, male elite athletes with a median (interquartile range) age of 23 (21; 29) years and maximum oxygen uptake (VO2max) of 63 (58; 66) ml/kg/min were randomly assigned to three different light exposure groups: bright light (BRIGHT), blue monochromatic light (BLUE), and control light (CONTROL). Each light exposure lasted 60 min and was scheduled to start 17 h after each individual's midpoint of sleep (median time: 9:17 pm). Immediately after light exposure, a 12-min time trial was performed on a bicycle ergometer. The test supervisor and participants were blinded to the light condition each participant was exposed to. The median received light intensities and peak wavelengths (photopic lx/nm) measured at eye level were 1319/545 in BRIGHT, 203/469 in BLUE, and 115/545 in CONTROL. In a multivariate analysis adjusted for individual VO2max, total work performed in 12 min did not significantly differ between the three groups. The amount of exposure to non-image forming light was positively associated with the performance gain during the time trial, defined as the ratio of the work performed in the first and last minute of the time trial, and with stronger melatonin suppression. Specifically, a tenfold increase in the exposure to melanopic light was associated with a performance gain of 8.0% (95% confidence interval: 2.6, 13.3; P = 0.004) and a melatonin decrease of -0.9 pg/ml (95% confidence interval: -1.5, -0.3; P = 0.006). Exposure to bright or blue light did not significantly improve maximum cycling performance in a 12-min all-out time trial. However, it is noteworthy that the estimated difference of 4.1 kJ between BRIGHT and CONTROL might represent an important performance advantage justifying further studies. In conclusion, we report novel evidence that evening light exposure, which strongly impacts the human circadian timing system, enables elite athletes to better maintain performance across a 12-min cycling time trial.

  8. Prime Time Light Exposures Do Not Seem to Improve Maximal Physical Performance in Male Elite Athletes, but Enhance End-Spurt Performance

    PubMed Central

    Knaier, Raphael; Schäfer, Juliane; Rossmeissl, Anja; Klenk, Christopher; Hanssen, Henner; Höchsmann, Christoph; Cajochen, Christian; Schmidt-Trucksäss, Arno

    2017-01-01

    Many sports competitions take place during television prime time, a time of the day when many athletes have already exceeded their time of peak performance. We assessed the effect of different light exposure modalities on physical performance and melatonin levels in athletes during prime time. Seventy-two young, male elite athletes with a median (interquartile range) age of 23 (21; 29) years and maximum oxygen uptake (VO2max) of 63 (58; 66) ml/kg/min were randomly assigned to three different light exposure groups: bright light (BRIGHT), blue monochromatic light (BLUE), and control light (CONTROL). Each light exposure lasted 60 min and was scheduled to start 17 h after each individual's midpoint of sleep (median time: 9:17 pm). Immediately after light exposure, a 12-min time trial was performed on a bicycle ergometer. The test supervisor and participants were blinded to the light condition each participant was exposed to. The median received light intensities and peak wavelengths (photopic lx/nm) measured at eye level were 1319/545 in BRIGHT, 203/469 in BLUE, and 115/545 in CONTROL. In a multivariate analysis adjusted for individual VO2max, total work performed in 12 min did not significantly differ between the three groups. The amount of exposure to non-image forming light was positively associated with the performance gain during the time trial, defined as the ratio of the work performed in the first and last minute of the time trial, and with stronger melatonin suppression. Specifically, a tenfold increase in the exposure to melanopic light was associated with a performance gain of 8.0% (95% confidence interval: 2.6, 13.3; P = 0.004) and a melatonin decrease of −0.9 pg/ml (95% confidence interval: −1.5, −0.3; P = 0.006). Exposure to bright or blue light did not significantly improve maximum cycling performance in a 12-min all-out time trial. However, it is noteworthy that the estimated difference of 4.1 kJ between BRIGHT and CONTROL might represent an important performance advantage justifying further studies. In conclusion, we report novel evidence that evening light exposure, which strongly impacts the human circadian timing system, enables elite athletes to better maintain performance across a 12-min cycling time trial. PMID:28507521

  9. Protection of quality and innovation in radiation oncology: the prospective multicenter trial QUIRO of DEGRO: evaluation of time, attendance of medical staff, and resources during radiotherapy with tomotherapy.

    PubMed

    Winkler, Cornelia; Duma, M N; Popp, W; Sack, H; Budach, V; Molls, M; Kampfer, S

    2014-10-01

    The technical progress in radiotherapy in recent years has been tremendous. This also implies a change of human and time resources. However, there is a lack of data on this topic. Therefore, the DEGRO initiated several studies in the QUIRO project on this subject. The present publication focuses on results for tomotherapy systems and compares them with other IMRT techniques. Over a period of several months, time allocation was documented using a standard form at two university hospitals. The required time for individual steps in the treatment planning process was recorded for all involved professional groups (physicist, technician, and physician) by themselves. The time monitoring at the treatment machines was performed by auxiliary employees (student research assistants). Evaluation of the data was performed for all recorded data as well as by tumor site. A comparison was made between the two involved institutions. A total of 1,691 records were analyzed: 148 from head and neck (H&N) tumors, 460 from prostate cancer, 136 from breast cancer, and 947 from other tumor entities. The mean value of all data from both centers for the definition of the target volumes for H&N tumors took a radiation oncology specialist 75 min, while a physicist needed for the physical treatment planning 214 min. For prostate carcinomas, the times were 60 and 147 min, respectively, and for the group of other entities 63 and 192 min, respectively. For the first radiation treatment, the occupancy time of the linear accelerator room was 31, 26, and 30 min for each entity (H&N, prostate, other entities, respectively). For routine treatments 22, 18, and 21 min were needed for the particular entities. Major differences in the time required for the individual steps were observed between the two centers. This study gives an overview of the time and personnel requirements in radiation therapy using a tomotherapy system. The most representative analysis could be done for the room occupancy times during treatment in both centers. Due to the partly small amount of data and differing planning workflows between the two centers, it is problematic to draw a firm conclusion with regard to planning times. Overall, the time required for the tomotherapy treatment and planning is slightly higher compared to other IMRT techniques.

  10. Reaction profiling by ultra high-pressure liquid chromatography/time-of-flight mass spectrometry in support of the synthesis of DNA-encoded libraries.

    PubMed

    Hargiss, Leonard O; Zipp, G Greg; Jessop, Theodore C; Sun, Xuejun; Keyes, Philip; Rawlins, David B; Liang, Zhi; Park, Kum Joo; Gu, Huizhong

    2014-11-15

    An ultra high-pressure liquid chromatography/mass spectrometry (UHPLC/MS) separation and analysis method has been devised for open access analysis of synthetic reactions used in the production of DNA-encoded chemical libraries. The aqueous mobile phase is 100mM hexafluoroisopropanol and 8.6mM triethylamine; the organic mobile phase is methanol. The UHPLC separation uses a C18 OST column (50mm×2.1mm×1.7μm) at 60°C, with a flow rate of 0.6mL/min. Gradient concentration is from 10 to 40% B in 1.0min, increasing to 95% B at 1.2min. Cycle time was about 5min. This method provides a detection limit of a 20-mer oligonucleotide by mass spectrometry of better than 1pmol on-column. Linear UV response for 20-mer extends from 2 to 200pmol/μL in concentration, same-day relative average deviations are less than 5% and bias (observed minus expected) is less than 10%. Deconvoluted mass spectra are generated for components in the predicted mass range using a maximum entropy algorithm. Mass accuracy of deconvoluted spectra is typically 20ppm or better for isotopomers of oligonucleotides up to 7000Da. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Exercise Capacity and Response to Training Quantitative Trait Loci in a NZW X 129S1 Intercross and Combined Cross Analysis of Inbred Mouse Strains

    PubMed Central

    Massett, Michael P.; Avila, Joshua J.; Kim, Seung Kyum

    2015-01-01

    Genetic factors determining exercise capacity and the magnitude of the response to exercise training are poorly understood. The aim of this study was to identify quantitative trait loci (QTL) associated with exercise training in mice. Based on marked differences in training responses in inbred NZW (-0.65 ± 1.73 min) and 129S1 (6.18 ± 3.81 min) mice, a reciprocal intercross breeding scheme was used to generate 285 F2 mice. All F2 mice completed an exercise performance test before and after a 4-week treadmill running program, resulting in an increase in exercise capacity of 1.54 ± 3.69 min (range = -10 to +12 min). Genome-wide linkage scans were performed for pre-training, post-training, and change in run time. For pre-training exercise time, suggestive QTL were identified on Chromosomes 5 (57.4 cM, 2.5 LOD) and 6 (47.8 cM, 2.9 LOD). A significant QTL for post-training exercise capacity was identified on Chromosome 5 (43.4 cM, 4.1 LOD) and a suggestive QTL on Chromosomes 1 (55.7 cM, 2.3 LOD) and 8 (66.1 cM, 2.2 LOD). A suggestive QTL for the change in run time was identified on Chromosome 6 (37.8 cM, 2.7 LOD). To identify shared QTL, this data set was combined with data from a previous F2 cross between B6 and FVB strains. In the combined cross analysis, significant novel QTL for pre-training exercise time and change in exercise time were identified on Chromosome 12 (54.0 cM, 3.6 LOD) and Chromosome 6 (28.0 cM, 3.7 LOD), respectively. Collectively, these data suggest that combined cross analysis can be used to identify novel QTL and narrow the confidence interval of QTL for exercise capacity and responses to training. Furthermore, these data support the use of larger and more diverse mapping populations to identify the genetic basis for exercise capacity and responses to training. PMID:26710100

  12. Technical Performance Reduces during the Extra-Time Period of Professional Soccer Match-Play

    PubMed Central

    Harper, Liam D.; West, Daniel J.; Stevenson, Emma; Russell, Mark

    2014-01-01

    Despite the importance of extra-time in determining progression in specific soccer tournament matches, few studies have profiled the demands of 120-minutes of soccer match-play. With a specific focus on the extra-time period, and using a within-match approach, we examined the influence of prolonged durations of professional soccer match-play on markers of technical (i.e., skilled) performance. In 18 matches involving professional European teams played between 2010 and 2014, this retrospective study quantified the technical actions observed during eight 15-minute epochs (E1: 00∶00–14∶59 min, E2: 15∶00–29∶59 min, E3: 30∶00–44∶59 min, E4: 45∶00–59∶59 min, E5: 60∶00–74∶59 min, E6: 75∶00–89∶59 min, E7: 90∶00–104∶59 min, E8: 105∶00–119∶59 min). Analysis of players who completed the demands of the full 120 min of match-play revealed that the cumulative number of successful passes observed during E8 (61±23) was lower than E1–4 (E1: 88±23, P = 0.001; E2: 77±21, P = 0.005; E3: 79±18, P = 0.001; E4: 80±21, P = 0.001) and E7 (73±20, P = 0.002). Similarly, the total number of passes made in E8 (71±25) was reduced when compared to E1 (102±22, P = 0.001), E3 (91±19, P = 0.002), E4 (93±22, P≤0.0005) and E7 (84±20, P = 0.001). The cumulative number of successful dribbles reduced in E8 (9±4) when compared to E1 (14±4, P = 0.001) and E3 (12±4, P≤0.0005) and the total time the ball was in play was less in E8 (504±61 s) compared to E1 (598±70 s, P≤0.0005). These results demonstrate that match-specific factors reduced particular indices of technical performance in the second half of extra-time. Interventions that seek to maintain skilled performance throughout extra-time warrant further investigation. PMID:25343724

  13. Flow injection analysis of organic peroxide explosives using acid degradation and chemiluminescent detection of released hydrogen peroxide.

    PubMed

    Mahbub, Parvez; Zakaria, Philip; Guijt, Rosanne; Macka, Mirek; Dicinoski, Greg; Breadmore, Michael; Nesterenko, Pavel N

    2015-10-01

    The applicability of acid degradation of organic peroxides into hydrogen peroxide in a pneumatically driven flow injection system with chemiluminescence reaction with luminol and Cu(2+) as a catalyst (FIA-CL) was investigated for the fast and sensitive detection of organic peroxide explosives (OPEs). The target OPEs included hexamethylene triperoxide diamine (HMTD), triacetone triperoxide (TATP) and methylethyl ketone peroxide (MEKP). Under optimised conditions maximum degradations of 70% and 54% for TATP and HMTD, respectively were achieved at 162 µL min(-1), and 9% degradation for MEKP at 180 µL min(-1). Flow rates were precisely controlled in this single source pneumatic pressure driven multi-channel FIA system by model experiments on mixing of easily detectable component solutions. The linear range for detection of TATP, HMTD and H2O2 was 1-200 µM (r(2)=0.98-0.99) at both flow rates, while that for MEKP was 20-200 µM (r(2)=0.97) at 180 µL min(-1). The detection limits (LODs) obtained were 0.5 µM for TATP, HMTD and H2O2 and 10 µM for MEKP. The detection times varied from 1.5 to 3 min in this FIA-CL system. Whilst the LOD for H2O2 was comparable with those reported by other investigators, the LODs and analysis times for TATP and HMTD were superior, and significantly, this is the first time the detection of MEKP has been reported by FIA-CL. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Tachycardic and non-tachycardic responses in trauma patients with haemorrhagic injuries.

    PubMed

    Reisner, Andrew T; Edla, Shwetha; Liu, Jianbo; Liu, Jiankun; Khitrov, Maxim Y; Reifman, Jaques

    2018-04-30

    Analyses of large databases have demonstrated that the association between heart rate (HR) and blood loss is weaker than what is taught by Advanced Trauma Life Support training. However, those studies had limited ability to generate a more descriptive paradigm, because they only examined a single HR value per patient. In a comparative, retrospective analysis, we studied the temporal characteristics of HR through time in adult trauma patients with haemorrhage, based on documented injuries and transfusion of ≥3 units of red blood cells (RBCs). We analysed archived vital-sign data of up to 60 min during either pre-hospital or emergency department care. We identified 133 trauma patients who met the inclusion criteria for major haemorrhage and 1640 control patients without haemorrhage. There were 55 haemorrhage patients with a normal median HR and 78 with tachycardia. Median ΔHR was -0.8 and +0.7 bpm per 10 min, respectively. Median time to documented hypotension was 8 and 5 min, respectively. RBCs were not significantly different; median volumes were 6 (IQR: 4-13) and 10 units (IQR: 5-16), respectively. Time-to-hypotension and mortality were not significantly different. Tachycardic patients were significantly younger (P < 0.05). Only 10 patients with normal HR developed transient/temporary tachycardia, and only 11 tachycardic patients developed a transient/temporary normal HR. The current analysis suggests that some trauma patients with haemorrhage are continuously tachycardic while others have a normal HR. For both cohorts, hypotension typically develops within 30 min, without any consistent temporal increases or trends in HR. Published by Elsevier Ltd.

  15. Anesthetic Activity of Alfaxalone Compared with Ketamine in Mice

    PubMed Central

    Siriarchavatana, Parkpoom; Ayers, Jessica D; Kendall, Lon V

    2016-01-01

    Alfaxalone encased in hydroxypropyl-β-cyclodextrin is a neuroactive steroid compound that has recently been approved in the United States for use as an anesthetic in dogs and cats. We evaluated the use of alfaxalone compared with ketamine, both alone and in combination with xylazine, for anesthesia of C57BL/6 mice. We assessed time to onset of anesthesia, duration of action, reflex responses, respiratory rate, and clinical signs. Alfaxalone (80 mg/kg IP) induced a light surgical plane of anesthesia in all mice, with a time to onset of 2.2 ± 0.2 min and duration of 57.1 ± 3.8 min, whereas ketamine (80 mg/kg IP) provided only sedative effects (time to onset, 5.4 ± 0.4 min; duration, 6.9 ± 0.8 min). Clinically, alfaxalone caused a spectrum of activities, including popcorn-like jumping movements after injection, intense scratching of the face, hyperresponsiveness to noise or touch, and marked limb jerking during recovery. Adding xylazine to the single-agent protocols achieved deep surgical anesthesia (duration: alfaxalone + xylazine, 80.3 ± 17.8 min; ketamine + xylazine, 37.4 ± 8.2 min) and ameliorated the adverse clinical signs. Our preliminary analysis suggests that, because of its side effects, alfaxalone alone is not a viable anesthetic option for mice. Although alfaxalone combined with xylazine appeared to be a more viable option, some mice still experienced mild adverse reactions, and the long duration of action might be problematic regarding the maintenance of body temperature and monitoring of recovery. Further studies evaluating different routes of administration and drug combinations are warranted. PMID:27423149

  16. Effect of tramadol as an adjuvant to local anesthetics for brachial plexus block: A systematic review and meta-analysis

    PubMed Central

    Ju, Bum Jun; Jang, Yoo Kyung; You, Hae Seun; Kang, Hyun; Park, Ji Yong

    2017-01-01

    Background Tramadol, a 4-phenyl-piperidine analog of codeine, has a unique action in that it has a central opioidergic, noradrenergic, serotonergic analgesic, and peripheral local anesthetic (LA) effect. Many studies have reported contradictory findings regarding the peripheral analgesic effect of tramadol as an adjuvant to LA in brachial plexus block (BPB). This meta-analysis aimed to evaluate the effects of tramadol as an adjunct to LA in BPB during shoulder or upper extremity surgery. Methods We searched the PubMed, EMBASE, Cochrane, KoreaMed databases, and Google Scholar for eligible randomized controlled trials (RCTs) that compared BPB with LA alone and BPB with LA and tramadol. Primary outcomes were the effects of tramadol as an adjuvant on duration of sensory block, motor block, and analgesia. Secondary outcomes were the effects of tramadol as an adjuvant on time to onset of sensory block and motor block and on adverse effects. We performed the meta-analysis using Review Manager 5.3 software. Results We identified 16 RCTs with 751 patients. BPB with tramadol prolonged the duration of sensory block (mean difference [MD], -61.5 min; 95% CI, -95.5 to -27.6; P = 0.0004), motor block (MD, -65.6 min; 95% CI, -101.5 to -29.7; P = 0.0003), and analgesia (MD, -125.5 min; 95% CI, -175.8 to -75.3; P < 0.0001) compared with BPB without tramadol. Tramadol also shortened the time to onset of sensory block (MD, 2.1 min; 95% CI, 1.1 to 3.1; P < 0.0001) and motor block (MD, 1.2 min; 95% CI, 0.2 to 2.1; P = 0.010). In subgroup analysis, the duration of sensory block, motor block, and analgesia was prolonged for BPB with tramadol 100 mg (P < 0.05) but not for BPB with tramadol 50 mg. The quality of evidence was high for duration of analgesia according to the GRADE system. Adverse effects were comparable between the studies. Conclusions In upper extremity surgery performed under BPB, use of tramadol 100 mg as an adjuvant to LA appears to prolong the duration of sensory block, motor block, and analgesia, and shorten the time to onset of sensory and motor blocks without altering adverse effects. PMID:28953949

  17. Effect of tramadol as an adjuvant to local anesthetics for brachial plexus block: A systematic review and meta-analysis.

    PubMed

    Shin, Hye Won; Ju, Bum Jun; Jang, Yoo Kyung; You, Hae Seun; Kang, Hyun; Park, Ji Yong

    2017-01-01

    Tramadol, a 4-phenyl-piperidine analog of codeine, has a unique action in that it has a central opioidergic, noradrenergic, serotonergic analgesic, and peripheral local anesthetic (LA) effect. Many studies have reported contradictory findings regarding the peripheral analgesic effect of tramadol as an adjuvant to LA in brachial plexus block (BPB). This meta-analysis aimed to evaluate the effects of tramadol as an adjunct to LA in BPB during shoulder or upper extremity surgery. We searched the PubMed, EMBASE, Cochrane, KoreaMed databases, and Google Scholar for eligible randomized controlled trials (RCTs) that compared BPB with LA alone and BPB with LA and tramadol. Primary outcomes were the effects of tramadol as an adjuvant on duration of sensory block, motor block, and analgesia. Secondary outcomes were the effects of tramadol as an adjuvant on time to onset of sensory block and motor block and on adverse effects. We performed the meta-analysis using Review Manager 5.3 software. We identified 16 RCTs with 751 patients. BPB with tramadol prolonged the duration of sensory block (mean difference [MD], -61.5 min; 95% CI, -95.5 to -27.6; P = 0.0004), motor block (MD, -65.6 min; 95% CI, -101.5 to -29.7; P = 0.0003), and analgesia (MD, -125.5 min; 95% CI, -175.8 to -75.3; P < 0.0001) compared with BPB without tramadol. Tramadol also shortened the time to onset of sensory block (MD, 2.1 min; 95% CI, 1.1 to 3.1; P < 0.0001) and motor block (MD, 1.2 min; 95% CI, 0.2 to 2.1; P = 0.010). In subgroup analysis, the duration of sensory block, motor block, and analgesia was prolonged for BPB with tramadol 100 mg (P < 0.05) but not for BPB with tramadol 50 mg. The quality of evidence was high for duration of analgesia according to the GRADE system. Adverse effects were comparable between the studies. In upper extremity surgery performed under BPB, use of tramadol 100 mg as an adjuvant to LA appears to prolong the duration of sensory block, motor block, and analgesia, and shorten the time to onset of sensory and motor blocks without altering adverse effects.

  18. Analysis of apple beverages treated with high-power ultrasound: a quality function deployment approach.

    PubMed

    Režek Jambrak, Anet; Šimunek, Marina; Grbeš, Franjo; Mandura, Ana; Djekic, Ilija

    2018-04-01

    The objective of this paper was to demonstrate application of quality function deployment in analysing effects of high power ultrasound on quality properties of apple juices and nectars. In order to develop a quality function deployment model, joint with instrumental analysis of treated samples, a field survey was performed to identify consumer preferences towards quality characteristics of juices/nectar. Based on field research, the three most important characteristics were 'taste' and 'aroma' with 28.5% of relative absolute weight importance, followed by 'odour' (16.9%). The quality function deployment model showed that the top three 'quality scores' for apple juice were treatments with amplitude 90 µm, 9 min treatment time and sample temperature 40 °C; 60 µm, 9 min, 60 °C; and 90 µm, 6 min, 40 °C. For nectars, the top three were treatments 120 µm, 9 min, 20 °C; 60 µm, 9 min, 60 °C; and A2.16 60 µm, 9 min, 20 °C. This type of quality model enables a more complex measure of large scale of different quality parameters. Its simplicity should be understood as its practical advantage and, as such, this tool can be a part of design quality when using novel preservation technologies. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  19. Performance comparison of heuristic algorithms for task scheduling in IaaS cloud computing environment.

    PubMed

    Madni, Syed Hamid Hussain; Abd Latiff, Muhammad Shafie; Abdullahi, Mohammed; Abdulhamid, Shafi'i Muhammad; Usman, Mohammed Joda

    2017-01-01

    Cloud computing infrastructure is suitable for meeting computational needs of large task sizes. Optimal scheduling of tasks in cloud computing environment has been proved to be an NP-complete problem, hence the need for the application of heuristic methods. Several heuristic algorithms have been developed and used in addressing this problem, but choosing the appropriate algorithm for solving task assignment problem of a particular nature is difficult since the methods are developed under different assumptions. Therefore, six rule based heuristic algorithms are implemented and used to schedule autonomous tasks in homogeneous and heterogeneous environments with the aim of comparing their performance in terms of cost, degree of imbalance, makespan and throughput. First Come First Serve (FCFS), Minimum Completion Time (MCT), Minimum Execution Time (MET), Max-min, Min-min and Sufferage are the heuristic algorithms considered for the performance comparison and analysis of task scheduling in cloud computing.

  20. Performance comparison of heuristic algorithms for task scheduling in IaaS cloud computing environment

    PubMed Central

    Madni, Syed Hamid Hussain; Abd Latiff, Muhammad Shafie; Abdullahi, Mohammed; Usman, Mohammed Joda

    2017-01-01

    Cloud computing infrastructure is suitable for meeting computational needs of large task sizes. Optimal scheduling of tasks in cloud computing environment has been proved to be an NP-complete problem, hence the need for the application of heuristic methods. Several heuristic algorithms have been developed and used in addressing this problem, but choosing the appropriate algorithm for solving task assignment problem of a particular nature is difficult since the methods are developed under different assumptions. Therefore, six rule based heuristic algorithms are implemented and used to schedule autonomous tasks in homogeneous and heterogeneous environments with the aim of comparing their performance in terms of cost, degree of imbalance, makespan and throughput. First Come First Serve (FCFS), Minimum Completion Time (MCT), Minimum Execution Time (MET), Max-min, Min-min and Sufferage are the heuristic algorithms considered for the performance comparison and analysis of task scheduling in cloud computing. PMID:28467505

  1. Determination of semi-volatile additives in wines using SPME and GC-MS.

    PubMed

    Sagandykova, Gulyaim N; Alimzhanova, Mereke B; Nurzhanova, Yenglik T; Kenessov, Bulat

    2017-04-01

    Parameters of headspace solid-phase microextraction, such as fiber coating (85μm CAR/PDMS), extraction time (2min for white and 3min for red wines), temperature (85°C), pre-incubation time (15min) were optimized for identification and quantification of semi-volatile additives (propylene glycol, sorbic and benzoic acids) in wines. To overcome problems in their determination, an evaporation of the wine matrix was performed. Using the optimized method, screening of 25 wine samples was performed, and the presence of propylene glycol, sorbic and benzoic acids was found in 22, 20 and 6 samples, respectively. Analysis of different wines using a standard addition approach showed good linearity in concentration ranges 0-250, 0-125, and 0-250mg/L for propylene glycol, sorbic and benzoic acids, respectively. The proposed method can be recommended for quality control of wine and disclosing adulterated samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Physical exertion and immediate mental performance of sixth-grade children.

    PubMed

    McNaughten, D; Gabbard, C

    1993-12-01

    The intent of this investigation was to examine the potential influence of varying durations of physical exertion at different times of the day on immediate mathematical performance by 120 sixth-grade boys and girls. Subjects were assigned to two control and two treatment groups (Solomon Four-group Design), with treated subjects administered physical exertion (paced walking at controlled moderate intensity) for durations of 20, 30, and 40 min. at three different times of the school day [8:30 a.m., 11:50 a.m. (before lunch), 2:20 p.m.] over 3 weeks. After each exertion session, subjects were immediately administered a 90-sec. mathematical computation test. Analysis indicated no significant differences in mathematical performance at any duration in the morning, but scores were significantly higher at 11:50 a.m. and 2:20 p.m. at 30- and 40-min. durations in comparison to the 20-min. duration. There were no differences by gender of subject.

  3. Structural and optical properties of PbS thin films grown by chemical bath deposition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seghaier, S.; Kamoun, N.; Guasch, C.

    2007-09-19

    Lead sulphide thin films are grown on glass substrates at various deposition times tD, in the range of 40-60 min per step of 2 min, using the chemical bath deposition technique. X-ray diffraction and atomic force microscopy are used to characterize the film structure. The surface composition is analysed by Auger electron spectroscopy. It appears that the as-prepared thin films are polycrystalline with cubic structure. Nanometric scale crystallites are uniformly distributed on the surface. They exhibit almost a stoechiometric composition with a [Pb]/[S] ratio equal to 1.10. Optical properties are studied in the range of 300-3300 nm by spectrophotometric measurements.more » Analysis of the optical absorption data of lead sulphide thin layers reveals a narrow optical direct band gap equal to 0.46 eV for the layer corresponding to a deposition time equal to 60 min.« less

  4. Cycling Time Trial Performance 4 Hours After Glycogen-Lowering Exercise Is Similarly Enhanced by Recovery Nondairy Chocolate Beverages Versus Chocolate Milk.

    PubMed

    Upshaw, Adam U; Wong, Tiffany S; Bandegan, Arash; Lemon, Peter W

    2016-02-01

    Postexercise chocolate milk ingestion has been shown to enhance both glycogen resynthesis and subsequent exercise performance. To assess whether nondairy chocolate beverage ingestion post-glycogen-lowering exercise can enhance 20-km cycling time trial performance 4 hr later, eight healthy trained male cyclists (21.8 ± 2.3y, VO2max = 61.2 ± 1.4 ml·kg-1·min-1; M ± SD) completed a series of intense cycling intervals designed to lower muscle glycogen (Jentjens & Jeukendrup, 2003) followed by 4 hr of recovery and a subsequent 20-km cycling time trial. During the first 2 hr of recovery, participants ingested chocolate dairy milk (DAIRYCHOC), chocolate soy beverage (SOYCHOC), chocolate hemp beverage (HEMPCHOC), low-fat dairy milk (MILK), or a low-energy artificially sweetened, flavored beverage (PLACEBO) at 30-min intervals in a double-blind, counterbalanced repeated-measures design. All drinks, except the PLACEBO (247 kJ) were isoenergetic (2,107 kJ), and all chocolate-flavored drinks provided 1-g CHO·kg body mass-1·h-1. Fluid intake across treatments was equalized (2,262 ± 148 ml) by ingesting appropriate quantities of water based on drink intake. The CHO:PRO ratio was 4:1, 1.5:1, 4:1, and 6:1 for DAIRYCHOC, MILK, SOYCHOC, and HEMPCHOC, respectively. One-way analysis of variance with repeated measures showed time trial performance (DAIRYCHOC = 34.58 ± 2.5 min, SOYCHOC = 34.83 ± 2.2 min, HEMPCHOC = 34.88 ± 1.1 min, MILK = 34.47 ± 1.7 min) was enhanced similarly vs PLACEBO (37.85 ± 2.1) for all treatments (p = .019) These data suggest that postexercise macronutrient and total energy intake are more important for same-day 20-km cycling time trial performance after glycogen-lowering exercise than protein type or protein-to-carbohydrate ratio.

  5. Hospital blood bank information systems accurately reflect patient transfusion: results of a validation study.

    PubMed

    McQuilten, Zoe K; Schembri, Nikita; Polizzotto, Mark N; Akers, Christine; Wills, Melissa; Cole-Sinclair, Merrole F; Whitehead, Susan; Wood, Erica M; Phillips, Louise E

    2011-05-01

    Hospital transfusion laboratories collect information regarding blood transfusion and some registries gather clinical outcomes data without transfusion information, providing an opportunity to integrate these two sources to explore effects of transfusion on clinical outcomes. However, the use of laboratory information system (LIS) data for this purpose has not been validated previously. Validation of LIS data against individual patient records was undertaken at two major centers. Data regarding all transfusion episodes were analyzed over seven 24-hour periods. Data regarding 596 units were captured including 399 red blood cell (RBC), 95 platelet (PLT), 72 plasma, and 30 cryoprecipitate units. They were issued to: inpatient 221 (37.1%), intensive care 109 (18.3%), outpatient 95 (15.9%), operating theater 45 (7.6%), emergency department 27 (4.5%), and unrecorded 99 (16.6%). All products recorded by LIS as issued were documented as transfused to intended patients. Median time from issue to transfusion initiation could be calculated for 535 (89.8%) components: RBCs 16 minutes (95% confidence interval [CI], 15-18 min; interquartile range [IQR], 7-30 min), PLTs 20 minutes (95% CI, 15-22 min; IQR, 10-37 min), fresh-frozen plasma 33 minutes (95% CI, 14-83 min; IQR, 11-134 min), and cryoprecipitate 3 minutes (95% CI, -10 to 42 min; IQR, -15 to 116 min). Across a range of blood component types and destinations comparison of LIS data with clinical records demonstrated concordance. The difference between LIS timing data and patient clinical records reflects expected time to transport, check, and prepare transfusion but does not affect the validity of linkage for most research purposes. Linkage of clinical registries with LIS data can therefore provide robust information regarding individual patient transfusion. This enables analysis of joint data sets to determine the impact of transfusion on clinical outcomes. © 2010 American Association of Blood Banks.

  6. Modelling of the optimal bupivacaine dose for spinal anaesthesia in ambulatory surgery based on data from systematic review.

    PubMed

    Lemoine, Adrien; Mazoit, Jean X; Bonnet, Francis

    2016-11-01

    Spinal bupivacaine is used for day-case surgery but the appropriate dose that guarantees hospital discharge is unknown. We sought to determine the spinal bupivacaine dose that prevents delayed hospital discharge in ambulatory surgery. Systematic review of clinical trials. Comprehensive search in electronic databases of studies published between 1996 and 2014 reporting the use of spinal bupivacaine in ambulatory patients. Additional articles were retrieved through hyperlinks and by manually searching reference lists in original articles, review articles and correspondence published in English and French. Data were used to calculate, motor block duration and discharge time, an estimated maximal effect (Emax: maximum theoretical time of motor block) and the effective dose to obtain half of Emax (D50) with 95% confidence intervals (CIs). A simulation was performed to determine the dose corresponding to a time to recovery of 300 min for motor function, and 360 min for discharge, in 95% of the patients. In total, 23 studies (1062 patients) were included for analysis of the time to recovery of motor function, and 12 studies (618 patients) for the time to hospital discharge. The Emax for recovery of motor function was 268 min [95% CI (189 to 433 min)] and the D50 was 3.9 mg [95% CI (2.3 to 6.2 mg)]. A 7.5-mg dose of bupivacaine enables resolution of motor block and ambulation within 300 min in 95% of the patients. A 5-mg dose or less was associated with an unacceptable failure rate. Ambulatory surgery is possible under spinal anaesthesia with bupivacaine although the dose range that ensures reliable anaesthesia with duration short enough to guarantee ambulatory management is narrow.

  7. Timelines in the management of adrenal crisis - targets, limits and reality.

    PubMed

    Hahner, Stefanie; Hemmelmann, Nina; Quinkler, Marcus; Beuschlein, Felix; Spinnler, Christina; Allolio, Bruno

    2015-04-01

    To evaluate current management timelines in adrenal crisis (AC) and to establish time targets and time limits for emergency treatment. Patients from a prospective study who had reported an AC (n = 46) were contacted and asked about management of their AC. A survey among 24 European endocrinologists collected expert recommendations concerning time targets and time limits for contact-arrival time of emergency health professionals and presentation of emergency card-glucocorticoid (GC) injection time. Median time targets and time limits regarded by experts as adequate for contact-arrival time were 45 and 90 min, respectively, and for card-injection time 15 and 30 min, respectively. Thirty-seven of 46 patients could be interviewed. All patients were equipped with an emergency card but only 23 (62%) with an emergency kit. Seven patients (19%) were trained in GC self-injection. The median time interval between contacting a health professional and arrival was 20 min (range 2-2880 min); ≤45 min: n = 32 (86%), <90 min: n = 34 (92%). The median time interval between arrival and administration of GC was 30 min (range 2-2400 min); ≤15 min: n = 17 (46%), ≤30 min: n = 20 (54%). While the time between contacting health professionals and their arrival was within the limits set by experts, initiation of GC administration was delayed in 46% of patients. Thus, improved management of AC needs to focus on shortening the presentation of card-injection time. Given the current reality in the management of AC, promotion of self-injection of GC (s.c. or i.m.) is warranted. © 2014 John Wiley & Sons Ltd.

  8. 18F-PSMA-1007 PET/CT at 60 and 120 minutes in patients with prostate cancer: biodistribution, tumour detection and activity kinetics.

    PubMed

    Rahbar, Kambiz; Afshar-Oromieh, Ali; Bögemann, Martin; Wagner, Stefan; Schäfers, Michael; Stegger, Lars; Weckesser, Matthias

    2018-03-14

    PSMA-targeted PET in patients with prostate cancer (PCa) has a significant impact on treatment decisions. By far the most frequently used PSMA ligand is 68 Ga-labelled PSMA-11. However, due to the availability of larger amounts of activity, 18 F-labelled PSMA ligands are of major interest. The aim of the present study was to evaluate the biodistribution and performance of the novel 18 F-labelled ligand PSMA-1007 at two different time points. This retrospective analysis included 40 consecutive patients (mean age 68.7 ± 8.1 years) referred for PSMA PET/CT. 18 F-PSMA-1007 PET/CT was performed for localization of biochemical relapse, primary staging or therapy follow-up. Circular regions of interest were placed on representative slices of the liver, spleen, kidney, abdominal aortic blood pool, bone marrow (fourth lumbar vertebral body), urinary bladder and gluteus muscle at 60 and 120 min after injection. In malignant lesions the maximum standardized uptake (SUV max ) was measured within volumes of interest at both time points. All SUVs at 60 min were compared with those at 120 min after injection. The activity in the blood pool, urinary bladder and gluteus muscle was very low and decreased significantly over time (P < 0.001). Uptake in the liver, spleen and kidney showed a significant increase over time and uptake in the bone marrow remained stable. Overall, 135 PCa lesions were detected at 60 min and 136 lesions at 120 min after injection. The median SUV max increased significantly (P < 0.001) from 10.98 to 15.51 between 60 and 120 min. PCa lesions show a significant increase in 18 F-PSMA-1007 uptake at 120 min compared with 60 min after injection. In addition, accumulation of the tracer in the urinary bladder was very low leading to improved contrast of adjacent PCa lesions. Increasing accumulation in the liver may limit the sensitivity of the tracer in detecting liver metastases.

  9. The golden 35 min of stroke intervention with ADAPT: effect of thrombectomy procedural time in acute ischemic stroke on outcome.

    PubMed

    Alawieh, Ali; Pierce, Alyssa K; Vargas, Jan; Turk, Aquilla S; Turner, Raymond D; Chaudry, M Imran; Spiotta, Alejandro M

    2018-03-01

    In acute ischemic stroke (AIS), extending mechanical thrombectomy procedural times beyond 60 min has previously been associated with an increased complication rate and poorer outcomes. After improvements in thrombectomy methods, to reassess whether this relationship holds true with a more contemporary thrombectomy approach: a direct aspiration first pass technique (ADAPT). We retrospectively studied a database of patients with AIS who underwent ADAPT thrombectomy for large vessel occlusions. Patients were dichotomized into two groups: 'early recan', in which recanalization (recan) was achieved in ≤35 min, and 'late recan', in which procedures extended beyond 35 min. 197 patients (47.7% women, mean age 66.3 years) were identified. We determined that after 35 min, a poor outcome was more likely than a good (modified Rankin Scale (mRS) score 0-2) outcome. The baseline National Institutes of Health Stroke Scale (NIHSS) score was similar between 'early recan' (n=122) (14.7±6.9) and 'late recan' patients (n=75) (15.9±7.2). Among 'early recan' patients, recanalization was achieved in 17.8±8.8 min compared with 70±39.8 min in 'late recan' patients. The likelihood of achieving a good outcome was higher in the 'early recan' group (65.2%) than in the 'late recan' group (38.2%; p<0.001). Patients in the 'late recan' group had a higher likelihood of postprocedural hemorrhage, specifically parenchymal hematoma type 2, than those in the 'early recan' group. Logistic regression analysis showed that baseline NIHSS, recanalization time, and atrial fibrillation had a significant impact on 90-day outcomes. Our findings suggest that extending ADAPT thrombectomy procedure times beyond 35 min increases the likelihood of complications such as intracerebral hemorrhage while reducing the likelihood of a good outcome. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  10. Introduction of an operating room information management system improved overall operating room efficiency.

    PubMed

    De Deyne, Cathy; Heylen, René

    2004-01-01

    Operating Room (OR) information systems should manage the OR time, assigned to every surgeon, thereby minimizing the sum of costs of unused OR time and minimizing the costs of elective cases performed outside normal allocated OR time (excess OR-time). The aim of this paper is to illustrate how the introduction of an OR information system influenced daily OR activity performance. Since January 2001, we introduced an OR information system with a visual, airport-like, screen as central part, displaying all scheduled OR activity linked in real-time activity with all OR theatres. For the aim of this paper, we compared all data of OR activity for elective abdominal surgery (EAS) for the first half of 2000 compared to the first half of 2001, after the introduction of our information system. In 2000, 764 elective cases were performed, compared to 815 cases in 2001. For both periods, the total OR time allocated to EAS for this 6 months period was 805 h. For 2000, the total duration of OR activity for EAS was 1044 h 50 min (implicating 239 h 50 min over-time), compared to 1127 h 35 min (implicating 322 h 35 min overtime) for 2001. For 2000, we recorded 147 h 20 min excess time (=exceeding the time limits of OR activity and inducing extra costs) and 46h45min unused OR time. For 2001, we recorded 123 h 04 min excess time and 35 h 21 min unused time. In conclusion, in 2001 we recorded an increase in total OR activity for elective abdominal surgery by 7% in number of procedures and by 8% in total duration. However, in 2001 we recorded a decrease in excess time by 16% (123 h 04 min vs 147 h 20 min), which was for a large part due to a 23% decrease in unused OR time in 2001 compared to 2000 (35 h 21min vs 46 h 45 min). Therefore, the introduction of an OR information system, with a real-time visual display of ongoing OR activity, resulted in a increased performance of OR activity, with more OR procedures performed despite less excess time and less extra costs.

  11. Pilot Analysis of Late Conversion to Belatacept in Kidney Transplant Recipients for Biopsy-Proven Chronic Tacrolimus Toxicity

    PubMed Central

    Rosales, Ivy

    2018-01-01

    Background Calcineurin inhibitors are associated with chronic nephrotoxicity, manifesting as interstitial fibrosis/tubular atrophy (IF/TA) and arteriolar hyalinosis. Conversion from tacrolimus to belatacept may be one strategy to preserve renal function. Methods We conducted a retrospective review of renal transplant patients followed at our institution who were converted to belatacept and found to have chronic tacrolimus toxicity on biopsy. The primary outcome was eGFR at conversion as compared to eGFR at 3, 6, 12, and 24 months after conversion. We also assessed incidence of infection and rates of allograft survival at 1 year. Results The average time between transplant and conversion was 11.9 years. There was no decrease in eGFR at any postconversion time point as compared with preconversion. The mean eGFR at time of preconversion was 32.9 mL/min, as compared with 35.6 mL/min at 3 months (p = 0.09), 34.1 mL/min at 6 months (p = 0.63), 34.9 mL/min at 12 months (p = 0.57), and 39.6 mL/min at 24 months after conversion (p = 0.92). Four of 7 patients had increases in their eGFR after conversion. All grafts were functioning at 1 year after conversion. Conclusion While this study was limited by a small number of patients, belatacept conversion stabilized eGFR at all time points in patients with late allograft function due to chronic tacrolimus toxicity, with a trend towards increased eGFR at 3 months. PMID:29854421

  12. Evidence for Sequential and Increasing Activation of Replication Origins along Replication Timing Gradients in the Human Genome

    PubMed Central

    Guilbaud, Guillaume; Rappailles, Aurélien; Baker, Antoine; Chen, Chun-Long; Arneodo, Alain; Goldar, Arach; d'Aubenton-Carafa, Yves; Thermes, Claude; Audit, Benjamin; Hyrien, Olivier

    2011-01-01

    Genome-wide replication timing studies have suggested that mammalian chromosomes consist of megabase-scale domains of coordinated origin firing separated by large originless transition regions. Here, we report a quantitative genome-wide analysis of DNA replication kinetics in several human cell types that contradicts this view. DNA combing in HeLa cells sorted into four temporal compartments of S phase shows that replication origins are spaced at 40 kb intervals and fire as small clusters whose synchrony increases during S phase and that replication fork velocity (mean 0.7 kb/min, maximum 2.0 kb/min) remains constant and narrowly distributed through S phase. However, multi-scale analysis of a genome-wide replication timing profile shows a broad distribution of replication timing gradients with practically no regions larger than 100 kb replicating at less than 2 kb/min. Therefore, HeLa cells lack large regions of unidirectional fork progression. Temporal transition regions are replicated by sequential activation of origins at a rate that increases during S phase and replication timing gradients are set by the delay and the spacing between successive origin firings rather than by the velocity of single forks. Activation of internal origins in a specific temporal transition region is directly demonstrated by DNA combing of the IGH locus in HeLa cells. Analysis of published origin maps in HeLa cells and published replication timing and DNA combing data in several other cell types corroborate these findings, with the interesting exception of embryonic stem cells where regions of unidirectional fork progression seem more abundant. These results can be explained if origins fire independently of each other but under the control of long-range chromatin structure, or if replication forks progressing from early origins stimulate initiation in nearby unreplicated DNA. These findings shed a new light on the replication timing program of mammalian genomes and provide a general model for their replication kinetics. PMID:22219720

  13. Time dependent reduction in platelet aggregation using the multiplate analyser and hirudin blood due to platelet clumping.

    PubMed

    Chapman, Kent; Favaloro, Emmanuel J

    2018-05-01

    The Multiplate is a popular instrument that measures platelet function using whole blood. Potentially considered a point of care instrument, it is also used by hemostasis laboratories. The instrument is usually utilized to assess antiplatelet medication or as a screen of platelet function. According to the manufacturer, testing should be performed within 0.5-3 hours of blood collection, and preferably using manufacturer provided hirudin tubes. We report time-associated reduction in platelet aggregation using the Multiplate and hirudin blood collection tubes, for all the major employed agonists. Blood for Multiplate analysis was collected into manufacturer supplied hirudin tubes, and 21 consecutive samples assessed using manufacturer supplied agonists (ADP, arachidonic acid, TRAP, collagen and ristocetin), at several time-points post-sample collection within the recommended test time period. Blood was also collected into EDTA as a reference method for platelet counts, with samples collected into sodium citrate and hirudin used for comparative counts. All platelet agonists showed a diminution of response with time. Depending on the agonist, the reduction caused 5-20% and 22-47% of responses initially in the normal reference range to fall below the reference range at 120min and 180min, respectively. Considering any agonist, 35% and 67% of initially "normal" responses became 'abnormal' at 120 min and 180 min, respectively. Platelet counts showed generally minimal changes in EDTA blood, but were markedly reduced over time in both citrate and hirudin blood, with up to 40% and 60% reduction, respectively, at 240 min. The presence of platelet clumping (micro-aggregate formation) was also observed in a time dependent manner, especially for hirudin. In conclusion, considering any platelet agonist, around two-thirds of samples can, within the recommended 0.5-3 hour testing window post-blood collection, yield a reduction in platelet aggregation that may lead to a change in interpretation (i.e., normal to reduced). Thus, the stability of Multiplate testing can more realistically be considered as being between 30-120 min of blood collection for samples collected into hirudin.

  14. Microwave-Assisted Synthesis of Goethite Nanoparticles Used for Removal of Cr(VI) from Aqueous Solution

    PubMed Central

    Kynicky, Jindrich; Adam, Vojtech

    2017-01-01

    The microwave-assisted synthesis of goethite nanoparticles has been studied. The samples were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), thermogravimetric analysis (TGA), differential thermal analysis (DTA) and Brunauer–Emmett–Teller (BET) method. Goethite rod-like nanoparticles have been successfully synthesized in 10 min of microwave treating at 100 °C. Particle size is in the range from 30 to 60 nm in width and from 200 to 350 nm in length. BET analysis indicated that the surface area of the product is 158.31 m2g−1. The feasibility of Cr(VI) removal fromaqueous solution depends on the pH of the solution and contact time. The maximum adsorptionis reached at pH 4.0 and 540 min of contact time. The adsorption kinetics was analyzedby the pseudo-first- and second-order models and the results reveal that the adsorption process obeys the pseudo-second-order model. The adsorption data were fitted well with the Langmuir adsorption isotherm. PMID:28773142

  15. [Local fractal analysis of noise-like time series by all permutations method for 1-115 min periods].

    PubMed

    Panchelyuga, V A; Panchelyuga, M S

    2015-01-01

    Results of local fractal analysis of 329-per-day time series of 239Pu alpha-decay rate fluctuations by means of all permutations method (APM) are presented. The APM-analysis reveals in the time series some steady frequency set. The coincidence of the frequency set with the Earth natural oscillations was demonstrated. A short review of works by different authors who analyzed the time series of fluctuations in processes of different nature is given. We have shown that the periods observed in those works correspond to the periods revealed in our study. It points to a common mechanism of the phenomenon observed.

  16. Modeling a 15-min extravehicular activity prebreathe protocol using NASA's exploration atmosphere (56.5 kPa/34% O2)

    NASA Astrophysics Data System (ADS)

    Abercromby, Andrew F. J.; Conkin, Johnny; Gernhardt, Michael L.

    2015-04-01

    NASA's plans for future human exploration missions utilize a new atmosphere of 56.5 kPa (8.2 psia), 34% O2, 66% N2 to enable rapid extravehicular activity (EVA) capability with minimal gas losses; however, existing EVA prebreathe protocols to mitigate risk of decompression sickness (DCS) are not applicable to the new exploration atmosphere. We provide preliminary analysis of a 15-min prebreathe protocol and examine the potential benefits of intermittent recompression (IR) and an abbreviated N2 purge on crew time and gas consumables usage. A probabilistic model of decompression stress based on an established biophysical model of DCS risk was developed, providing significant (p<0.0001) prediction and goodness-of-fit with 84 cases of DCS in 668 human altitude exposures including a variety of pressure profiles. DCS risk for a 15-min prebreathe protocol was then estimated under different exploration EVA scenarios. Estimated DCS risk for all EVA scenarios modeled using the 15-min prebreathe protocol ranged between 6.1% and 12.1%. Supersaturation in neurological tissues (5- and 10-min half-time compartments) is prevented and tissue tensions in faster half-time compartments (≤40 min), where the majority of whole-body N2 is located, are reduced to about the levels (30.0 vs. 27.6 kPa) achieved during a standard Shuttle prebreathe protocol. IR reduced estimated DCS risk from 9.7% to 7.9% (1.8% reduction) and from 8.4% to 6.1% (2.3% reduction) for the scenarios modeled; the penalty of N2 reuptake during IR may be outweighed by the benefit of decreased bubble size. Savings of 75% of purge gas and time (0.22 kg gas and 6 min of crew time per person per EVA) are achievable by abbreviating the EVA suit purge to 20% N2 vs. 5% N2 at the expense of an increase in estimated DCS risk from 9.7% to 12.1% (2.4% increase). A 15-min prebreathe protocol appears feasible using the new exploration atmosphere. IR between EVAs may enable reductions in suit purge and prebreathe requirements, decompression stress, and/or suit operating pressures. Ground trial validation is required before operational implementation.

  17. Pseudoephedrine and preexercise feeding: influence on performance.

    PubMed

    Pritchard-Peschek, Kellie R; Osborne, Mark A; Slater, Gary J; Taaffe, Dennis R; Jenkins, David G

    2013-06-01

    This study examined the influence of preexercise food intake on plasma pseudoephedrine (PSE) concentrations and subsequent high-intensity exercise. In addition, urinary PSE concentrations were measured under the same conditions and compared with the present threshold of the World Anti-Doping Agency (WADA). Ten highly trained male cyclists and triathletes (age = 30.6 ± 6.6 yr, body mass [BM] = 72.9 ± 5.1 kg, and V˙O2max = 64.8 ± 4.5 mL·kg·min; mean ± SD) undertook four cycling time trials (TT), each requiring the completion of a set amount of work (7 kJ·kg BM) in the shortest possible time. Participants were randomized into a fed or nonfed condition and orally ingested 2.8 mg·kg BM of PSE or a placebo (PLA) 90 min before exercise; in the fed trials, they consumed a meal providing 1.5 g·kg BM of CHO. Venous blood was sampled at 30, 50, and 70 min and pre-warm-up and postexercise for the analysis of plasma PSE and catecholamine concentrations, and urine was also collected for the analysis of PSE concentration. Independent of the preexercise meal, 2.8 mg·kg BM of PSE did not significantly improve cycling TT performance. The fed trials resulted in lower plasma PSE concentrations at all time points compared with the nonfed trials. Both plasma epinephrine and blood lactate concentrations were higher in the PSE compared with the PLA trials, and preexercise and postexercise urinary PSE concentrations were significantly higher than the threshold (150 μg·mL) used by WADA to determine illicit PSE use. Irrespective of the preexercise meal, cycling TT performance of approximately 30 min was not improved after PSE supplementation. Furthermore, 2.8 mg·kg BM of PSE taken 90 min before exercise, with or without food, resulted in urinary PSE concentrations exceeding the present WADA threshold.

  18. Early endocrine attending surgeon presence increases operating room efficiency.

    PubMed

    Clark, Audra; Dackiw, Alan P; White, Wendy D; Nwariaku, Fiemu E; Holt, Shelby A; Rabaglia, Jennifer L; Oltmann, Sarah C

    2016-10-01

    Preincision operating room (OR) preparation varies greatly. Cases requiring exacting preoperative setup may be more sensitive to inconsistent team members and trainees. Leadership and oversight by the surgeon may facilitate a timely start. The study hypothesized that early attending presence in the OR expedites surgery start time, improving efficiency, and decreasing cost. Prospective data collection of endocrine surgery cases at an urban teaching hospital was performed. Time points recorded in minutes. Cost/min of OR time was $54. Patients classified as in the OR ≤10 min before attending arrival or >10 min before attending arrival. A total of 227 cases (166 thyroid, 54 parathyroid, 10 adrenal) were performed over 14 mo. Of the patients, 128 were in the OR ≤10 min before attending arrival, and 99 patients were >10 min (3 ± 3 min versus 35 ± 14 min, P < 0.01). The ≤10 min procedures started sooner after patient arrival in OR (40 ± 11 versus 63 ± 19, P < 0.01) which equated to $1202 of savings before incision. Although attending time in the OR before incision was equivalent between groups for adrenal and parathyroid, time to incision was shorter in the ≤10 min groups, saving $2416 ± 477 and $1458 ± 244, respectively (P < 0.01). Attending time in OR before thyroidectomy was 13 min longer in ≤10 min than >10 min (P < 0.01), but incisions were made 20 min sooner (P < 0.01) equating to $1076 ± 120 in savings. Early attending presence in the OR shortens time to incision. For parathyroid and adrenal cases, this does not require additional surgeon time. In ORs without consistent teams, early attending presence in the OR improves efficiency and yields significant cost savings. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Multicenter Clinical Trials Using 18F-FDG PET to Measure Early Response to Oncologic Therapy: Effects of Injection-to-Acquisition Time Variability on Required Sample Size.

    PubMed

    Kurland, Brenda F; Muzi, Mark; Peterson, Lanell M; Doot, Robert K; Wangerin, Kristen A; Mankoff, David A; Linden, Hannah M; Kinahan, Paul E

    2016-02-01

    Uptake time (interval between tracer injection and image acquisition) affects the SUV measured for tumors in (18)F-FDG PET images. With dissimilar uptake times, changes in tumor SUVs will be under- or overestimated. This study examined the influence of uptake time on tumor response assessment using a virtual clinical trials approach. Tumor kinetic parameters were estimated from dynamic (18)F-FDG PET scans of breast cancer patients and used to simulate time-activity curves for 45-120 min after injection. Five-minute uptake time frames followed 4 scenarios: the first was a standardized static uptake time (the SUV from 60 to 65 min was selected for all scans), the second was uptake times sampled from an academic PET facility with strict adherence to standardization protocols, the third was a distribution similar to scenario 2 but with greater deviation from standards, and the fourth was a mixture of hurried scans (45- to 65-min start of image acquisition) and frequent delays (58- to 115-min uptake time). The proportion of out-of-range scans (<50 or >70 min, or >15-min difference between paired scans) was 0%, 20%, 44%, and 64% for scenarios 1, 2, 3, and 4, respectively. A published SUV correction based on local linearity of uptake-time dependence was applied in a separate analysis. Influence of uptake-time variation was assessed as sensitivity for detecting response (probability of observing a change of ≥30% decrease in (18)F-FDG PET SUV given a true decrease of 40%) and specificity (probability of observing an absolute change of <30% given no true change). Sensitivity was 96% for scenario 1, and ranged from 73% for scenario 4 (95% confidence interval, 70%-76%) to 92% (90%-93%) for scenario 2. Specificity for all scenarios was at least 91%. Single-arm phase II trials required an 8%-115% greater sample size for scenarios 2-4 than for scenario 1. If uptake time is known, SUV correction methods may raise sensitivity to 87%-95% and reduce the sample size increase to less than 27%. Uptake-time deviations from standardized protocols occur frequently, potentially decreasing the performance of (18)F-FDG PET response biomarkers. Correcting SUV for uptake time improves sensitivity, but algorithm refinement is needed. Stricter uptake-time control and effective correction algorithms could improve power and decrease costs for clinical trials using (18)F-FDG PET endpoints. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  20. A pilot study: the efficacy of virgin coconut oil as ocular rewetting agent on rabbit eyes.

    PubMed

    Mutalib, Haliza Abdul; Kaur, Sharanjeet; Ghazali, Ahmad Rohi; Chinn Hooi, Ng; Safie, Nor Hasanah

    2015-01-01

    Purpose. An open-label pilot study of virgin coconut oil (VCO) was conducted to determine the safety of the agent as ocular rewetting eye drops on rabbits. Methods. Efficacy of the VCO was assessed by measuring NIBUT, anterior eye assessment, corneal staining, pH, and Schirmer value before instillation and at 30 min, 60 min, and two weeks after instillation. Friedman test was used to analyse any changes in all the measurable variables over the period of time. Results. Only conjunctival redness with instillation of saline agent showed significant difference over the period of time (P < 0.05). However, further statistical analysis had shown no significant difference at 30 min, 60 min, and two weeks compared to initial measurement (P > 0.05). There were no changes in the NIBUT, limbal redness, palpebral conjunctiva redness, corneal staining, pH, and Schirmer value over the period of time for each agent (P > 0.05). Conclusion. VCO acts as safe rewetting eye drops as it has shown no significant difference in the measurable parameter compared to commercial brand eye drops and saline. These study data suggest that VCO is safe to be used as ocular rewetting agent on human being.

  1. Response surface methodology approach for optimization of adsorption of Janus Green B from aqueous solution onto ZnO/Zn(OH)2-NP-AC: Kinetic and isotherm study

    NASA Astrophysics Data System (ADS)

    Ghaedi, M.; Khafri, H. Zare; Asfaram, A.; Goudarzi, A.

    2016-01-01

    The Janus Green B (JGB) adsorption onto homemade ZnO/Zn(OH)2 nanoparticles loaded on activated carbon (AC) which characterized by FESEM and XRD analysis has been reported. Combination of response surface methodology (RSM) and central composite design (CCD) has been employed to model and optimize variables using STATISTICA 10.0 software. The influence of parameters over pH (2.0-8.0), adsorbent (0.004-0.012 g), sonication time (4-8 min) and JGB concentration (3-21 mg L-1) on JGB removal percentage was investigated and their main and interaction contribution was examined. It was revealed that 21 mg L-1 JGB, 0.012 g ZnO/Zn(OH)2-NP-AC at pH 7.0 and 7 min sonication time permit to achieve removal percentage more than 99%. Finally, a good agreement between experimental and predicted values after 7 min was achieved using pseudo-second-order rate equation. The Langmuir adsorption is appropriate for correlation of equilibrium data. The small amount of adsorbent (0.008-0.015 g) is applicable for successful removal of JGB (RE > 99%) in short time (7 min) with high adsorption capacity (81.3-98.03 mg g-1).

  2. A Pilot Study: The Efficacy of Virgin Coconut Oil as Ocular Rewetting Agent on Rabbit Eyes

    PubMed Central

    Mutalib, Haliza Abdul; Kaur, Sharanjeet; Ghazali, Ahmad Rohi; Chinn Hooi, Ng; Safie, Nor Hasanah

    2015-01-01

    Purpose. An open-label pilot study of virgin coconut oil (VCO) was conducted to determine the safety of the agent as ocular rewetting eye drops on rabbits. Methods. Efficacy of the VCO was assessed by measuring NIBUT, anterior eye assessment, corneal staining, pH, and Schirmer value before instillation and at 30 min, 60 min, and two weeks after instillation. Friedman test was used to analyse any changes in all the measurable variables over the period of time. Results. Only conjunctival redness with instillation of saline agent showed significant difference over the period of time (P < 0.05). However, further statistical analysis had shown no significant difference at 30 min, 60 min, and two weeks compared to initial measurement (P > 0.05). There were no changes in the NIBUT, limbal redness, palpebral conjunctiva redness, corneal staining, pH, and Schirmer value over the period of time for each agent (P > 0.05). Conclusion. VCO acts as safe rewetting eye drops as it has shown no significant difference in the measurable parameter compared to commercial brand eye drops and saline. These study data suggest that VCO is safe to be used as ocular rewetting agent on human being. PMID:25802534

  3. Is da Vinci Xi Better than da Vinci Si in Robotic Rectal Cancer Surgery? Comparison of the 2 Generations of da Vinci Systems.

    PubMed

    Ozben, Volkan; Cengiz, Turgut B; Atasoy, Deniz; Bayraktar, Onur; Aghayeva, Afag; Erguner, Ilknur; Baca, Bilgi; Hamzaoglu, Ismail; Karahasanoglu, Tayfun

    2016-10-01

    We aimed to compare perioperative outcomes for procedures using the latest generation of da Vinci robot versus its previous version in rectal cancer surgery. Fifty-three patients undergoing robotic rectal cancer surgery between January 2010 and March 2015 were included. Patients were classified into 2 groups (Xi, n=28 vs. Si, n=25) and perioperative outcomes were analyzed. The groups had significant differences including operative procedure, hybrid technique and redocking (P>0.05). In univariate analysis, the Xi group had shorter console times (265.7 vs. 317.1 min, P=0.006) and total operative times (321.6 vs. 360.4 min, P=0.04) and higher number of lymph nodes harvested (27.5 vs. 17.0, P=0.008). In multivariate analysis, Xi robot was associated with a shorter console time (odds ratio: 0.09, P=0.004) with no significant differences regarding other outcomes. Both generations of da Vinci robot led to similar short-term outcomes in rectal cancer surgery, but the Xi robot allowed shorter console times.

  4. Two-steps microwave-assisted treatment on acid hydrolysis of sago pith for bioethanol production

    NASA Astrophysics Data System (ADS)

    Sunarti, T. C.; Yanti, S. D.; Ruriani, E.

    2017-05-01

    Sago is a genus of palm that can be utilized to produce fermentable sugars as substrate for bioethanol. Sago pith is a heterogeneous substrate consists of starch and fiber. Acid hydrolysis by microwave heating radiation can break down starch and fibers together in a very short time, so it is considered to be very efficient process. The use of microwave energy (as power level) and variation of heating time can produce fermentable sugar with certain characteristics. This study included the preparation and analysis of sago pith flour; process of acid hydrolysis (0.3 M and 0.5 M H2SO4) using two steps microwave heating, first with power level 30% (1, 2 and 3 min) and second with power level 70% (3 min); and ethanol production. The conventional treatment (autoclaving at 121°C for 15 min) was carried for the comparison. The highest fermentable sugar (105.7 g/l) was resulted from microwave heating with power level 30% for 2 min followed by the power level 70% for 3 min. This hydrolyzate then used as substrate for bioethanol fermentation and partially neutralized (pH 3, 4, 5) by using yeast Issatchenkia orientalis, and the highest ethanol (2.8 g/l) was produced in pH 5.

  5. The Influence of Running on Foot Posture and In-Shoe Plantar Pressures.

    PubMed

    Bravo-Aguilar, María; Gijón-Noguerón, Gabriel; Luque-Suarez, Alejandro; Abian-Vicen, Javier

    2016-03-01

    Running can be considered a high-impact practice, and most people practicing continuous running experience lower-limb injuries. The aim of this study was to determine the influence of 45 min of running on foot posture and plantar pressures. The sample comprised 116 healthy adults (92 men and 24 women) with no foot-related injuries. The mean ± SD age of the participants was 28.31 ± 6.01 years; body mass index, 23.45 ± 1.96; and training time, 11.02 ± 4.22 h/wk. Outcome measures were collected before and after 45 min of running at an average speed of 12 km/h, and included the Foot Posture Index (FPI) and a baropodometric analysis. The results show that foot posture can be modified after 45 min of running. The mean ± SD FPI changed from 6.15 ± 2.61 to 4.86 ± 2.65 (P < .001). Significant decreases in mean plantar pressures in the external, internal, rearfoot, and forefoot edges were found after 45 min of running. Peak plantar pressures in the forefoot decreased after running. The pressure-time integral decreased during the heel strike phase in the internal edge of the foot. In addition, a decrease was found in the pressure-time integral during the heel-off phase in the internal and rearfoot edges. The findings suggest that after 45 min of running, a pronated foot tends to change into a more neutral position, and decreased plantar pressures were found after the run.

  6. CYP2C19 progress curve analysis and mechanism-based inactivation by three methylenedioxyphenyl compounds.

    PubMed

    Salminen, Kaisa A; Meyer, Achim; Imming, Peter; Raunio, Hannu

    2011-12-01

    Several in vitro criteria were used to assess whether three methylenedioxyphenyl (MDP) compounds, the isoquinoline alkaloids bulbocapnine, canadine, and protopine, are mechanism-based inactivators of CYP2C19. The recently reported fluorometric CYP2C19 progress curve analysis approach was applied first to determine whether these alkaloids demonstrate time-dependent inhibition. In this experiment, bulbocapnine, canadine, and protopine displayed time dependence and saturation in their inactivation kinetics with K(I) and k(inact) values of 72.4 ± 14.7 μM and 0.38 ± 0.036 min(-1), 2.1 ± 0.63 μM and 0.18 ± 0.015 min(-1), and 7.1 ± 2.3 μM and 0.24 ± 0.021 min(-1), respectively. Additional studies were performed to determine whether other specific criteria for mechanism-based inactivation were fulfilled: NADPH dependence, irreversibility, and involvement of a catalytic step in the enzyme inactivation. CYP2C19 activity was not significantly restored by dialysis when it had been inactivated by the alkaloids in the presence of a NADPH-regenerating system, and a metabolic-intermediate complex-associated increase in absorbance at approximately 455 nm was observed. In conclusion, the CYP2C19 progress curve analysis method revealed time-dependent inhibition by these alkaloids, and additional experiments confirmed its quasi-irreversible nature. This study revealed that the CYP2C19 progress curve analysis method is useful for identifying novel mechanism-based inactivators and yields a wealth of information in one run. The alkaloids bulbocapnine, canadine, and protopine, present in herbal medicines, are new mechanism-based inactivators and the first MDP compounds exhibiting quasi-irreversible inactivation of CYP2C19.

  7. Kinetic analysis of IMP split dose method for two consecutive measurement of cerebral blood flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nishizawa, S.; Yonekura, Y.; Tanaka, F.

    1994-05-01

    The split dose method for two consecutive measurements of cerebral blood flow (CBF) with I-123 IMP seems to offer a great merit to the SPECT study of the brain. However, because of complexity of the dynamics of IMP, it is not clear if microsphere (MS) model permits a estimation of CBF for the 2nd dose. We applied kinetic (KN) analysis based on 2 compartment model to the dynamic SPECT scan data, and compared the results with those obtained by MS model. Dynamic SPECT (1-min scans for 50 min) was performed using 3-head SPECT camera in 5 patients to test themore » reproducibility of measured CBF and in 9 patients to test the vascular response to acetazolamide (ACZ). Two doses of IMP (111 MBq each) were injected at the time of, and 25 min after, the scan initiation. ACZ (1g) was administered at 13 min. Arterial blood samples were drawn manually during the scan and an octanol extracted input function was obtained. Dynamic scan data for 22 min was used for CBF by KN analysis (K1), and 4-min scan data at 5 min for CBF by MS model (Km), for each dose. For 2nd CBF by MS model, simple subtraction of brain activity due to the I st dose was done using 4-min scan data just prior to the 2nd dose. Reproducibility of measured CBF by KN analysis was excellent (r=0.949, 1st K1=39.2{plus_minus}5.6 and 2nd K1=38.5{plus_minus}6.6 ml/l00g/min: mean{plus_minus}SD). Vascular response to ACZ was good (1st K1=42.4{plus_minus}7.8 to 2nd K1=67.9{plus_minus}10.0) in areas without ischemia, but poor (1st K1=41.1{plus_minus}8.5 to 2nd K1=46.1{plus_minus}11.1) in ischemic areas. Compared to KN analysis, MS model underestimated 3.5% for the 1st CBF measurement and 12.8% for the 2nd. However, excellent correlation was observed not only between 1st K1 and Km (r=0.993, slope=0.920) but between 2nd K1 and Km (r=0.994, slope=0.814), and the results permitted a reasonable correction for Km.« less

  8. MinOmics, an Integrative and Immersive Tool for Multi-Omics Analysis.

    PubMed

    Maes, Alexandre; Martinez, Xavier; Druart, Karen; Laurent, Benoist; Guégan, Sean; Marchand, Christophe H; Lemaire, Stéphane D; Baaden, Marc

    2018-06-21

    Proteomic and transcriptomic technologies resulted in massive biological datasets, their interpretation requiring sophisticated computational strategies. Efficient and intuitive real-time analysis remains challenging. We use proteomic data on 1417 proteins of the green microalga Chlamydomonas reinhardtii to investigate physicochemical parameters governing selectivity of three cysteine-based redox post translational modifications (PTM): glutathionylation (SSG), nitrosylation (SNO) and disulphide bonds (SS) reduced by thioredoxins. We aim to understand underlying molecular mechanisms and structural determinants through integration of redox proteome data from gene- to structural level. Our interactive visual analytics approach on an 8.3 m2 display wall of 25 MPixel resolution features stereoscopic three dimensions (3D) representation performed by UnityMol WebGL. Virtual reality headsets complement the range of usage configurations for fully immersive tasks. Our experiments confirm that fast access to a rich cross-linked database is necessary for immersive analysis of structural data. We emphasize the possibility to display complex data structures and relationships in 3D, intrinsic to molecular structure visualization, but less common for omics-network analysis. Our setup is powered by MinOmics, an integrated analysis pipeline and visualization framework dedicated to multi-omics analysis. MinOmics integrates data from various sources into a materialized physical repository. We evaluate its performance, a design criterion for the framework.

  9. Analysis of sulfidic linkages formed in natural rubber latex medical gloves by using X-ray absorption near edge structure

    NASA Astrophysics Data System (ADS)

    Chankrachang, M.; Limphirat, W.; Yongyingsakthavorn, P.; Nontakaew, U.; Tohsan, A.

    2017-09-01

    A study of sulfidic linkages formed in natural rubber (NR) latex medical gloves by using X-ray Absorption Near Edge Structure (XANES) is presented in this paper. The NR latex compound was prepared by using prevulcanization method, that is, it was prevulcanized at room temperature for 24 hrs before utilization. After the 24 hrs of prevulcanization, the latex film samples were obtained by dipping process. The dipped films were subjected to vulcanize at 110°C for 5 to 25 min. It was observed that after the compound was prevulcanized for 24 hrs, polysulfidic linkages were mainly formed in the sample. It was however found that after curing at 110°C for 5-25 min, the polysulfidic linkages are tended to change into disulfide linkages. Especially, in the case of 25 minutes cured sample, disulfide linkages are found to be the main linkages. In term of tensile strength, it was observed that when cure time increased from 5 - 10 min, tensile strengths were also increased. But when the cure time of the film is 25 minutes, tensile strength was slightly dropped. The dropped of tensile strength when cure time is longer than 10 minutes can be ascribed to a degradation of polysulfidic and disulfidic linkages during curing. Therefore, by using XANES analysis, it was found to be very useful to understand the cure characteristic, thus it can be very helpful to optimize cure time and tensile properties of the product.

  10. Study of Initial Stages of Ball-Milling of Cu Powder Using X-ray Diffraction

    NASA Astrophysics Data System (ADS)

    Gayathri, N.; Mukherjee, Paramita

    2018-04-01

    The initial stage of size refinement of Cu powder is studied using detailed X-ray diffraction (XRD) analysis to understand the mechanism of formation of nanomaterials during the ball-milling process. The study was restricted to samples obtained for milling time up to 240 min to understand the deformation mechanism at the early stages of ball milling. Various model based approaches for the analysis of the XRD were used to study the evolution of the microstructural parameters such as domain size and microstrain along the different crystallographic planes. It was seen that the domain size saturates at a low value along the (311) plane whereas the size along the (220) and (200) plane is still higher. The r.m.s microstrain showed a non-monotonic change along the different crystallographic directions up to the milling time of 240 min.

  11. MinION Analysis and Reference Consortium: Phase 2 data release and analysis of R9.0 chemistry.

    PubMed

    Jain, Miten; Tyson, John R; Loose, Matthew; Ip, Camilla L C; Eccles, David A; O'Grady, Justin; Malla, Sunir; Leggett, Richard M; Wallerman, Ola; Jansen, Hans J; Zalunin, Vadim; Birney, Ewan; Brown, Bonnie L; Snutch, Terrance P; Olsen, Hugh E

    2017-01-01

    Long-read sequencing is rapidly evolving and reshaping the suite of opportunities for genomic analysis. For the MinION in particular, as both the platform and chemistry develop, the user community requires reference data to set performance expectations and maximally exploit third-generation sequencing. We performed an analysis of MinION data derived from whole genome sequencing of Escherichia coli K-12 using the R9.0 chemistry, comparing the results with the older R7.3 chemistry. We computed the error-rate estimates for insertions, deletions, and mismatches in MinION reads. Run-time characteristics of the flow cell and run scripts for R9.0 were similar to those observed for R7.3 chemistry, but with an 8-fold increase in bases per second (from 30 bps in R7.3 and SQK-MAP005 library preparation, to 250 bps in R9.0) processed by individual nanopores, and less drop-off in yield over time. The 2-dimensional ("2D") N50 read length was unchanged from the prior chemistry. Using the proportion of alignable reads as a measure of base-call accuracy, 99.9% of "pass" template reads from 1-dimensional ("1D")  experiments were mappable and ~97% from 2D experiments. The median identity of reads was ~89% for 1D and ~94% for 2D experiments. The total error rate (miscall + insertion + deletion ) decreased for 2D "pass" reads from 9.1% in R7.3 to 7.5% in R9.0 and for template "pass" reads from 26.7% in R7.3 to 14.5% in R9.0. These Phase 2 MinION experiments serve as a baseline by providing estimates for read quality, throughput, and mappability. The datasets further enable the development of bioinformatic tools tailored to the new R9.0 chemistry and the design of novel biological applications for this technology. K: thousand, Kb: kilobase (one thousand base pairs), M: million, Mb: megabase (one million base pairs), Gb: gigabase (one billion base pairs).

  12. Intervention on Surgical Systemic-to-Pulmonary Artery Shunts: Carotid Versus Femoral Access.

    PubMed

    Ligon, R Allen; Ooi, Yinn K; Kim, Dennis W; Vincent, Robert N; Petit, Christopher J

    2017-09-11

    The purpose of this study was to compare results between the femoral arterial (FA) and carotid arterial (CA) approaches in catheter-based interventions on Blalock-Taussig shunts (BTS). Transcatheter intervention on BTS is often performed in shunt-dependent, hypoxemic infants. The approach to BTS intervention likely has an impact on timeliness and overall success. The authors reviewed all cases of catheter intervention for BTS obstruction between 2012 and 2017 for their institution. They sought to compare procedural success rates and time, sheath time, time to arterial access, and time from access to stent implantation between FA and CA approaches. There were 42 BTS interventions between 34 patients. BTS intervention was more successful from the CA approach (p = 0.035). Among the FA cohort, BTS intervention was unsuccessful in 8 cases (25%), 5 of which were converted to CA with subsequent success. The CA cohort had lower procedure time (62 min vs. 104 min; p = 0.01) and anesthesia time (119 min vs. 151 min; p = 0.01). Additionally, CA access was associated with shorter time to arterial access (4.0 min vs. 9.3 min; p < 0.01), time to placement of the guidewire through the BTS (6.5 min vs. 13 min; p < 0.01), and time from the final sheath to BTS stent implantation (9 min vs. 20 min; p < 0.01). Operators should consider the route of access to the BTS deliberately. The authors' approach has been the carotid artery as an alternative access site-associated with greater procedural success, shorter procedural time, and shorter time to stent implantation. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Plasma concentrations, behavioural and physiological effects following intravenous and intramuscular detomidine in horses.

    PubMed

    Mama, K R; Grimsrud, K; Snell, T; Stanley, S

    2009-11-01

    Detomidine hydrochloride is used to provide sedation, muscle relaxation and analgesia in horses, but a lack of information pertaining to plasma concentration has limited the ability to correlate drug concentration with effect. To build on previous information and assess detomidine for i.v. and i.m. use in horses by simultaneously assessing plasma drug concentrations, physiological parameters and behavioural characteristics. Systemic effects would be seen following i.m. and i.v. detomidine administration and these effects would be positively correlated with plasma drug concentrations. Behavioural (e.g. head position) and physiological (e.g. heart rate) responses were recorded at fixed time points from 4 min to 24 h after i.m. or i.v. detomidine (30 microg/kg bwt) administration to 8 horses. Route of administration was assigned using a balanced crossover design. Blood was sampled at predetermined time points from 0.5 min to 48 h post administration for subsequent detomidine concentration measurements using liquid chromatography-mass spectrometry. Data were summarised as mean +/- s.d. for subsequent analysis of variance for repeated measures. Plasma detomidine concentration peaked earlier (1.5 min vs. 1.5 h) and was significantly higher (105.4 +/- 71.6 ng/ml vs. 6.9 +/- 1.4 ng/ml) after i.v. vs. i.m. administration. Physiological and behavioural changes were of a greater magnitude and observed at earlier time points for i.v. vs. i.m. groups. For example, head position decreased from an average of 116 cm in both groups to a low value 35 +/- 23 cm from the ground 10 min following i.v. detomidine and to 64 +/- 24 cm 60 min after i.m. detomidine. Changes in heart rate followed a similar pattern; low value of 17 beats/min 10 min after i.v. administration and 29 beats/min 30 min after i.m. administration. Plasma drug concentration and measured effects were correlated positively and varied with route of administration following a single dose of detomidine. Results support a significant influence of route of administration on desirable and undesirable drug effects that influence case management.

  14. A Comprehensive Two-Dimensional Retention Time Alignment Algorithm To Enhance Chemometric Analysis of Comprehensive Two-Dimensional Separation Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pierce, Karisa M.; Wood, Lianna F.; Wright, Bob W.

    2005-12-01

    A comprehensive two-dimensional (2D) retention time alignment algorithm was developed using a novel indexing scheme. The algorithm is termed comprehensive because it functions to correct the entire chromatogram in both dimensions and it preserves the separation information in both dimensions. Although the algorithm is demonstrated by correcting comprehensive two-dimensional gas chromatography (GC x GC) data, the algorithm is designed to correct shifting in all forms of 2D separations, such as LC x LC, LC x CE, CE x CE, and LC x GC. This 2D alignment algorithm was applied to three different data sets composed of replicate GC x GCmore » separations of (1) three 22-component control mixtures, (2) three gasoline samples, and (3) three diesel samples. The three data sets were collected using slightly different temperature or pressure programs to engender significant retention time shifting in the raw data and then demonstrate subsequent corrections of that shifting upon comprehensive 2D alignment of the data sets. Thirty 12-min GC x GC separations from three 22-component control mixtures were used to evaluate the 2D alignment performance (10 runs/mixture). The average standard deviation of the first column retention time improved 5-fold from 0.020 min (before alignment) to 0.004 min (after alignment). Concurrently, the average standard deviation of second column retention time improved 4-fold from 3.5 ms (before alignment) to 0.8 ms (after alignment). Alignment of the 30 control mixture chromatograms took 20 min. The quantitative integrity of the GC x GC data following 2D alignment was also investigated. The mean integrated signal was determined for all components in the three 22-component mixtures for all 30 replicates. The average percent difference in the integrated signal for each component before and after alignment was 2.6%. Singular value decomposition (SVD) was applied to the 22-component control mixture data before and after alignment to show the restoration of trilinearity to the data, since trilinearity benefits chemometric analysis. By applying comprehensive 2D retention time alignment to all three data sets (control mixtures, gasoline samples, and diesel samples), classification by principal component analysis (PCA) substantially improved, resulting in 100% accurate scores clustering.« less

  15. Effects of delayed polymerization time and bracket manipulation on orthodontic resin modified glass ionomer adhesive

    NASA Astrophysics Data System (ADS)

    Gilbert, Danielle Wiggins

    This study examined the effect of varying delayed polymerization times in combination with bracket manipulation on shear bond strength (SBS), degree of conversion (DC), and adhesive remnant index (ARI) score when using a resin modified glass ionomer (RMGI) adhesive. Specimens were divided into three groups of clinically relevant delay times (0.5, 2, and 4-min) to simulate the delay that frequently occurs between bracket placement and manipulation and subsequent light curing. Based on an analysis of variance (alpha=.05), the SBS was not significantly different between the three groups. While one of the goals of this study was to be the first study to quantify DC of RMGI using Raman microspectroscopy, several challenges, including weak peak signal with and without fluorescence, were encountered and as a result, DC could not be determined. A significant difference (p<0.05) in ARI score was detected between the 0.5-min and 4.0-min delay groups with more adhesive remaining on the bracket with increasing delay time. A Spearman correlation between SBS and ARI indicated no positive association between SBS and ARI measures across delay times. The results of this study suggest that clinically relevant delay times of 0.5, 2, and 4-min do not negatively impact the SBS of a RMGI adhesive. However, with increasing delay time, the results suggest that more adhesive might remain on the bracket during debonding. With more adhesive remaining on the bracket, this could be beneficial in that less adhesive needs to be removed from enamel by grinding at the time of bracket removal when orthodontic treatment is completed.

  16. Stair climbing/descending exercise for a short time decreases blood glucose levels after a meal in people with type 2 diabetes.

    PubMed

    Honda, Hiroto; Igaki, Makoto; Hatanaka, Yuki; Komatsu, Motoaki; Tanaka, Shin-Ichiro; Miki, Tetsuo; Suzuki, Taiga; Takaishi, Tetsuo; Hayashi, Tatsuya

    2016-01-01

    We examined whether stair climbing-descending exercise (ST-EX), a convenient method to increase physical activity in daily life, for a short period would acutely improve the postprandial blood glucose (BG) response in people with type 2 diabetes (T2D). 16 people with T2D (age 65.4±1.1 years) participated in 2 separate sessions. After an overnight fast, each participant consumed a test meal and then kept resting for 180 min, except when performing each 3 min bout of ST-EX at 60 and 120 min after the meal (ST-EX session), or kept resting for 180 min (REST session). ST-EX comprised 6 continuous repetitions of climbing to the second floor (21 steps) at a rate of 80-110 steps/min followed by walking down slowly to the first floor at a free step rate. The BG at 60 min after the meal during the ST-EX session (immediately before the first ST-EX) did not differ from that during the REST session, but analysis of variance revealed a significant interaction between time and treatment (p<0.01). The BG at 150 min after the meal (30 min after the second ST-EX) was significantly lower than that during the REST session (p<0.01). The area under the curve was also 18% lower during the ST-EX session than during the REST session (p<0.05). The heart rate and blood lactate levels indicated that the actual intensity of ST-EX was 'hard'. In contrast, the rating of perceived exertion (RPE) indicated that the overall intensity of ST-EX was 'moderate' because of decreased RPE scores during descent. The present findings suggest that performing 3 min ST-EX 60 and 120 min after a meal may be a useful strategy to accelerate the decrease in postprandial BG levels in people with T2D.

  17. Fast and sensitive optical toxicity bioassay based on dual wavelength analysis of bacterial ferricyanide reduction kinetics.

    PubMed

    Pujol-Vila, F; Vigués, N; Díaz-González, M; Muñoz-Berbel, X; Mas, J

    2015-05-15

    Global urban and industrial growth, with the associated environmental contamination, is promoting the development of rapid and inexpensive general toxicity methods. Current microbial methodologies for general toxicity determination rely on either bioluminescent bacteria and specific medium solution (i.e. Microtox(®)) or low sensitivity and diffusion limited protocols (i.e. amperometric microbial respirometry). In this work, fast and sensitive optical toxicity bioassay based on dual wavelength analysis of bacterial ferricyanide reduction kinetics is presented, using Escherichia coli as a bacterial model. Ferricyanide reduction kinetic analysis (variation of ferricyanide absorption with time), much more sensitive than single absorbance measurements, allowed for direct and fast toxicity determination without pre-incubation steps (assay time=10 min) and minimizing biomass interference. Dual wavelength analysis at 405 (ferricyanide and biomass) and 550 nm (biomass), allowed for ferricyanide monitoring without interference of biomass scattering. On the other hand, refractive index (RI) matching with saccharose reduced bacterial light scattering around 50%, expanding the analytical linear range in the determination of absorbent molecules. With this method, different toxicants such as metals and organic compounds were analyzed with good sensitivities. Half maximal effective concentrations (EC50) obtained after 10 min bioassay, 2.9, 1.0, 0.7 and 18.3 mg L(-1) for copper, zinc, acetic acid and 2-phenylethanol respectively, were in agreement with previously reported values for longer bioassays (around 60 min). This method represents a promising alternative for fast and sensitive water toxicity monitoring, opening the possibility of quick in situ analysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Fast electrophoretic analysis of individual mitochondria using microchip capillary electrophoresis with laser induced fluorescence detection.

    PubMed

    Duffy, Ciarán F; MacCraith, Brian; Diamond, Dermot; O'Kennedy, Richard; Arriaga, Edgar A

    2006-08-01

    The analysis of mitochondria by capillary electrophoresis usually takes longer than 20 min per replicate which may compromise the quality of the mitochondria due to degradation. In addition, low sample consumption may be beneficial in the analysis of rare or difficult samples. In this report, we demonstrate the ability to analyze individual mitochondrial events in picoliter-volume samples (approximately 80 pL) taken from a bovine liver preparation using microchip capillary electrophoresis with laser-induced fluorescence detection (micro-chip CE-LIF). Using a commercial "double-T" glass microchip, the sample was electrokinetically loaded in the "double-T" intersection and then subjected to electrophoretic separation along the main separation channel. In order to decrease interactions of mitochondria with channel walls during the analysis, poly(vinyl alcohol) was used as a dynamic coating. This procedure eliminates the need for complicated covalent surface modifications within the channels that were previously used in capillary electrophoresis methods. For analysis, mitochondria, isolated from bovine liver tissue, were selectively labelled using 10-nonyl acridine orange (NAO). The results consist of electropherograms where each mitochondrial event is a narrow spike (240 +/- 44 ms). While the spike intensity is representative of its NAO content, its migration time is used to calculate and describe its electrophoretic mobility, which is a property still largely unexplored for intracellular organelles. The five-fold decrease in separation time (4 min for microchip versus 20 min for capillary electrophoresis) makes microchip electrophoretic separations of organelles a faster, sensitive, low-sample volume alternative for the characterization of individual organelle properties and for investigations of subcellular heterogeneity.

  19. Soft-copy sonography: cost reduction sensitivity analysis in a pediatric hospital.

    PubMed

    Don, S; Albertina, M J; Ammann, D

    1998-03-01

    Our objective was to determine whether interpreting sonograms of pediatric patients using soft-copy (computer workstation) instead of laser-printed film could reduce costs for a pediatric radiology department. We used theoretic models of growth to analyze costs. The costs of a sonographic picture archiving and communication system (three interface devices, two workstations, a network server, maintenance expenses, and storage media costs) were compared with the potential savings of eliminating film and increasing technologist efficiency or reducing the number of technologists. The model was based on historic trends and future capitation estimates that will reduce fee-for-service reimbursement. The effects of varying the study volume and reducing technologists' work hours were analyzed. By converting to soft-copy interpretation, we saved 6 min 32 sec per examination by eliminating film processing waiting time, thus reducing examination time from 30 min to 24 min. During an average day of 27 examinations, 176 min were saved. However, 33 min a day were spent retrieving prior studies from long-term storage; thus, 143 extra minutes a day were available for scanning. This improved efficiency could result in five more sonograms a day obtained by converting to soft-copy interpretation, using existing staff and equipment. Alternatively, five examinations a day would equate to one half of a full-time equivalent technologists position. Our analysis of costs considered that the hospital's anticipated growth of sonography and the depreciation of equipment during 5 years resulted in a savings of more than $606,000. Increasing the examinations by just 200 sonograms in the first year and no further growth resulted in a savings of more than $96,000. If the number of sonograms stayed constant, elimination of film printing alone resulted in a loss of approximately $157,000; reduction of one half of a full-time equivalent technologist's position would recuperate approximately $134,000 of that loss. Soft-copy sonography can save money through improved technologist efficiency, thereby increasing the number of sonograms obtained and revenue generated. If the number of sonograms does not increase, elimination of printing costs and reduction of staff technologists will not result in a savings.

  20. Swim drink study: a randomised controlled trial of during-exercise rehydration and swimming performance.

    PubMed

    Briars, Graham L; Gordon, Gillian Suzanne; Lawrence, Andrew; Turner, Andrew; Perry, Sharon; Pillbrow, Dan; Walston, Florence Einstein; Molyneux, Paul

    2017-01-01

    To determine whether during-exercise rehydration improves swimming performance and whether sports drink or water have differential effects on performance. Randomised controlled multiple crossover trial. A UK competitive swimming club. 19 club-level competitive swimmers, median age (range) 13 (11-17) years. Subjects were scheduled to drink ad libitum commercial isotonic sports drink (3.9 g sugars and 0.13 g salt per 100 mL) or water (three sessions each) or no drink (six sessions) in the course of twelve 75 min training sessions, each of which was followed by a 30 min test set of ten 100 m maximum-effort freestyle sprints each starting at 3 min intervals. Times for the middle 50 m of each sprint measured using electronic timing equipment in a Federation Internationale de Natation (FINA)-compliant six-lane 25 m competition swimming pool. Software-generated individual random session order in sealed envelopes. Analysis subset of eight sessions randomly selected by software after data collection completed. Participants blind to drink allocation until session start. In the analysis data set of 1118 swims, there was no significant difference between swim times for drinking and not drinking nor between drinking water or a sports drink. Mean (SEM) 50 m time for no-drink swims was 38.077 (0.128) s and 38.105 (0.131) s for drink swims, p=0.701. Mean 50 m times were 38.031 (0.184) s for drinking sports drink and 38.182 (0.186) s for drinking water, p=0.073. Times after not drinking were 0.027 s faster than after drinking (95% CI 0.186 s faster to 0.113 s slower). Times after drinking sports drink were 0.151 s faster than after water (95% CI 0.309 s faster to 0.002 s slower). Mean (SEM) dehydration from exercise was 0.42 (0.11)%. Drinking water or sports drink over 105 min of sustained effort swimming training does not improve swimming performance. ISRCTN: 49860006.

  1. Optimal imaging and analysis of human vaginal coating by drug delivery gels

    PubMed Central

    Henderson, Marcus H; Couchman, Grace M; Walmer, David K; Peters, Jennifer J; Owen, Derek H; Brown, Matthew A; Lavine, Michael L; Katz, David F

    2007-01-01

    Objective We used a new optical imaging technique to compare human intravaginal coating distributions of Conceptrol® and Advantage™. These gels are surrogates for future microbicidal gels, differing in molecular structures and biophysical properties. Methods For each protocol, a 3-mL gel bolus was inserted to the posterior fornix while the woman was in the supine position. She then either: (1) remained supine (10 min); or (2) sat up (1 min), stood up (1 min), sat down (1 min), and returned to supine for a net elapsed time of 10 min. The imaging device is sized/shaped like a phallus, and measurements while the device was inserted provide data that simulate peri-intromission coating. Results Coating by Advantage™ was more extensive and uniform than coating by Conceptrol®, with smaller bare spots of uncoated epithelium. Change in posture tended to increase extent and uniformity of coating, details differing between gels. Conclusions Results are consistent with predictions of mechanistic coating theory, using gel rheological data as inputs. PMID:17241845

  2. Comparative analysis of ultrasound changes in the vastus lateralis muscle following myofascial release and thermotherapy: a pilot study.

    PubMed

    Ichikawa, Kazuna; Takei, Hitoshi; Usa, Hideyuki; Mitomo, Shoh; Ogawa, Daisuke

    2015-04-01

    This study aimed to compare the effects of myofascial release (MFR) and hot pack therapy (HPT) on fascial gliding and flexibility of the vastus lateralis muscle. Three treatments were applied to the left vastus lateralis muscles of each participant (12 healthy males): MFR for 4 min, superficial HPT for 10 min, and superficial HPT for 20 min. Deep fascial motion was measured by B-mode ultrasound, whereas muscle stiffness was measured by real-time elastography (RTE) and a durometer before and after the interventions. Only MFR resulted in changes in both deep fascial motion and muscle stiffness measured by RTE. Durometer-measured muscle stiffness revealed changes following both MFR and 20-min HPT but not 10-min HPT. HPT may produce only superficial effects. Because MFR improved all measured parameters, continuous stretching and pressure are probably important for improving fascial gliding and flexibility of the vastus lateralis muscle. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Glass fabrics self-cracking catalytic growth of boron nitride nanotubes

    NASA Astrophysics Data System (ADS)

    Wang, Jilin; Peng, Daijang; Long, Fei; Wang, Weimin; Gu, Yunle; Mo, Shuyi; Zou, Zhengguang; Fu, Zhengyi

    2017-02-01

    Glass fabrics were used to fabricate boron nitride nanotubes (BNNTs) with a broad diameter range through a combined chemical vapor deposition and self-propagation high-temperature synthesis (CVD-SHS) method at different holding times (0min, 30min, 90min, 180min and 360min). SEM characterization has been employed to investigate the macro and micro structure/morphology changes of the glass fabrics and BNNTs in detail. SEM image analysis has provided direct experimental evidences for the rationality of the optimized self-cracking catalyst VLS growth mechanism, including the transformation situations of the glass fabrics and the BNNTs growth processes respectively. This paper was the further research and compensation for the theory and experiment deficiencies in the new preparation method of BNNTs reported in our previous work. In addition, it is likely that the distinctive self-cracking catalyst VLS growth mechanism could provide a new idea to preparation of other inorganic functional nano-materials using similar one-dimensional raw materials as growth templates and catalysts.

  4. Occurrence and duration of various operational definitions of sedentary bouts and cross-sectional associations with cardiometabolic health indicators: the ENERGY-project.

    PubMed

    Altenburg, T M; de Niet, M; Verloigne, M; De Bourdeaudhuij, I; Androutsos, O; Manios, Y; Kovacs, E; Bringolf-Isler, B; Brug, J; Chinapaw, M J M

    2015-02-01

    This study examined the occurrence and duration of sedentary bouts and explored the cross-sectional association with health indicators in children applying various operational definitions of sedentary bouts. Accelerometer data of 647 children (10-13 years old) were collected in five European countries. We analyzed sedentary time (<100 cpm) accumulated in bouts of at least 5, 10, 20 or 30 min based on four operational definitions, allowing 0, 30 or 60s ≥100 cpm within bouts. Health indicators included anthropometrics (i.e. waist circumference and body mass index (BMI)) and in a subsample from two European countries (n=112) fasting capillary blood levels of glucose, C-peptide, high-density- and low-density cholesterol, and triglycerides. Data collection took place from March to July 2010. Associations were adjusted for age, gender, moderate-to-vigorous physical activity, total wear time and country. Occurrence of sedentary bouts varied largely between the various definitions. Children spent most of their sedentary time in bouts of ≥5 min while bouts of ≥20 min were rare. Linear regression analysis revealed few significant associations of sedentary time accumulated in bouts of ≥5-30 min with health indicators. Moreover, we found that more associations became significant when allowing no tolerance time within sedentary bouts. Despite a few significant associations, we found no convincing evidence for an association between sedentary time accumulated in bouts and health indicators in 10-13 year old children. Copyright © 2015. Published by Elsevier Inc.

  5. Kinetics of removal of intravenous testosterone pulses in normal men.

    PubMed

    Veldhuis, Johannes D; Keenan, Daniel M; Liu, Peter Y; Takahashi, Paul Y

    2010-04-01

    Testosterone is secreted into the bloodstream episodically, putatively distributing into total, bioavailable (bio) nonsex hormone-binding globulin (nonSHBG-bound), and free testosterone moieties. The kinetics of total, bio, and free testosterone pulses are unknown. Design Adrenal and gonadal steroidogenesis was blocked pharmacologically, glucocorticoid was replaced, and testosterone was infused in pulses in four distinct doses in 14 healthy men under two different paradigms (a total of 220 testosterone pulses). Testosterone kinetics were assessed by deconvolution analysis of total, free, bioavailable, SHBG-bound, and albumin-bound testosterone concentration-time profiles. Independently of testosterone dose or paradigm, rapid-phase half-lives (min) of total, free, bioavailable, SHBG-bound, and albumin-bound testosterone were comparable at 1.4+/-0.22 min (grand mean+/-S.E.M. of geometric means). Slow-phase testosterone half-lives were highest for SHBG-bound testosterone (32 min) and total testosterone (27 min) with the former exceeding that of free testosterone (18 min), bioavailable testosterone (14 min), and albumin-bound testosterone (18 min; P<0.001). Collective outcomes indicate that i) the rapid phase of testosterone disappearance from point sampling in the circulation is not explained by testosterone dose; ii) SHBG-bound testosterone and total testosterone kinetics are prolonged; and iii) the half-lives of bioavailable, albumin-bound, and free testosterone are short. A frequent-sampling strategy comprising an experimental hormone clamp, estimation of hormone concentrations as bound and free moieties, mimicry of physiological pulses, and deconvolution analysis may have utility in estimating the in vivo kinetics of other hormones, substrates, and metabolites.

  6. Rheological Characterization as an Alternative Method to Indentation for Determining the Setting Time of Restorative and Endodontic Cements

    PubMed Central

    Nicholson, Timothy M.; Kahler, Bill

    2017-01-01

    This study explored an alternative approach using rheology to assess setting time. The following cements were tested: ProRoot® MTA (Dentsply, Tulsa, OK, USA), Biodentine® (Septodont, Saint Maur des Fosses, France), Fuji VII®, FujiVII® EP, and Fuji IX® (from GC Corporation, Tokyo, Japan), RealSeal SE™ Sealer (SybronEndo, Amersfoort, The Netherlands), AH 26® and AH Plus (both from Dentsply DeTrey, Konstanz, Germany). Freshly mixed cements were placed into a strain-controlled rheometer (1 rad·s−1 with an applied strain of 0.01%). From measurements of elastic modulus over time, the time taken to reach 90% of the plateau elastic modulus (designated as the setting time) was determined for each cement. In increasing order, the setting times were as follows: Fuji VII EP 3.3 min, Fuji VII 3.6 min, Fuji IX 3.7 min, ProRoot MTA 5.1 min, Biodentine 15.9 min, RealSeal 22.2 min, AH Plus 5933 min, and AH 26 5067 min. However, ProRoot MTA did not yield reliable results. The time to reach the 90% plateau elastic modulus correlates well with the setting time of glass ionomer cements and Biodentine. Using this approach gives much longer setting times for endodontic sealers than previously recognized. PMID:29261125

  7. Distribution of crystalloid fluid changes with the rate of infusion: a population-based study.

    PubMed

    Hahn, R G; Drobin, D; Zdolsek, J

    2016-05-01

    Crystalloid fluid requires 30 min for complete distribution throughout the extracellular fluid space and tends to cause long-standing peripheral edema. A kinetic analysis of the distribution of Ringer's acetate with increasing infusion rates was performed to obtain a better understanding of these characteristics of crystalloids. Data were retrieved from six studies in which 76 volunteers and preoperative patients had received between 300 ml and 2375 ml of Ringer's acetate solution at a rate of 20-80 ml/min (0.33-0.83 ml/min/kg). Serial measurements of the blood hemoglobin concentration were used as inputs in a kinetic analysis based on a two-volume model with micro-constants, using software for nonlinear mixed effects. The micro-constants describing distribution (k12) and elimination (k10) were unchanged when the rate of infusion increased, with half-times of 16 and 26 min, respectively. In contrast, the micro-constant describing how rapidly the already distributed fluid left the peripheral space (k21) decreased by 90% when the fluid was infused more rapidly, corresponding to an increase in the half-time from 3 to 30 min. The central volume of distribution (V(c)) doubled. The return of Ringer's acetate from the peripheral fluid compartment to the plasma was slower with high than with low infusion rates. Edema is a normal consequence of plasma volume expansion with this fluid, even in healthy volunteers. The results are consistent with the view that the viscoelastic properties of the interstitial matrix are responsible for the distribution and redistribution characteristics of crystalloid fluid. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  8. Effects of one versus two bouts of moderate intensity physical activity on selective attention during a school morning in Dutch primary schoolchildren: A randomized controlled trial.

    PubMed

    Altenburg, Teatske M; Chinapaw, Mai J M; Singh, Amika S

    2016-10-01

    Evidence suggests that physical activity is positively related to several aspects of cognitive functioning in children, among which is selective attention. To date, no information is available on the optimal frequency of physical activity on cognitive functioning in children. The current study examined the acute effects of one and two bouts of moderate-intensity physical activity on children's selective attention. Randomized controlled trial (ISRCTN97975679). Thirty boys and twenty-six girls, aged 10-13 years, were randomly assigned to three conditions: (A) sitting all morning working on simulated school tasks; (B) one 20-min physical activity bout after 90min; and (C) two 20-min physical activity bouts, i.e. at the start and after 90min. Selective attention was assessed at five time points during the morning (i.e. at baseline and after 20, 110, 130 and 220min), using the 'Sky Search' subtest of the 'Test of Selective Attention in Children'. We used GEE analysis to examine differences in Sky Search scores between the three experimental conditions, adjusting for school, baseline scores, self-reported screen time and time spent in sports. Children who performed two 20-min bouts of moderate-intensity physical activity had significantly better Sky Search scores compared to children who performed one physical activity bout or remained seated the whole morning (B=-0.26; 95% CI=[-0.52; -0.00]). Our findings support the importance of repeated physical activity during the school day for beneficial effects on selective attention in children. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  9. Microwave Energy Increases Fatty Acid Methyl Ester Yield in Human Whole Blood Due to Increased Sphingomyelin Transesterification.

    PubMed

    Metherel, Adam H; Aristizabal Henao, Juan J; Ciobanu, Flaviu; Taha, Ameer Y; Stark, Ken D

    2015-09-01

    Dried blood spots (DBS) by fingertip prick collection for fatty acid profiling are becoming increasingly popular due to ease of collection, minimal invasiveness and its amenability to high-throughput analyses. Herein, we assess a microwave-assisted direct transesterification method for the production of fatty acid methyl esters (FAME) from DBS. Technical replicates of human whole blood were collected and 25-μL aliquots were applied to chromatography strips prior to analysis by a standard 3-h transesterification method or microwave-assisted direct transesterification method under various power (variable vs constant), time (1-5 min) and reagent (1-10% H2SO4 in methanol) conditions. In addition, a standard method was compared to a 5-min, 30-W power microwave in 1% H2SO4 method for FAME yield from whole blood sphingomyelin, and sphingomyelin standards alone and spiked in whole blood. Microwave-assisted direct transesterification yielded no significant differences in both quantitative (nmol/100 µL) and qualitative (mol%) fatty acid assessments after as little as 1.5- and 1-min reaction times, respectively, using the variable power method and 5% H2SO4 in methanol. However, 30-W power for 5 min increased total FAME yield of the technical replicates by 14%. This increase appears largely due to higher sphingomyelin-derived FAME yield of up to 109 and 399% compared to the standard method when determined from whole blood or pure standards, respectively. In conclusion, microwave-assisted direct transesterification of DBS achieved in as little as 1-min, and 5-min reaction times increase total fatty acids primarily by significantly improving sphingomyelin-derived fatty acid yield.

  10. Novel method for high-throughput phenotyping of sleep in mice.

    PubMed

    Pack, Allan I; Galante, Raymond J; Maislin, Greg; Cater, Jacqueline; Metaxas, Dimitris; Lu, Shan; Zhang, Lin; Von Smith, Randy; Kay, Timothy; Lian, Jie; Svenson, Karen; Peters, Luanne L

    2007-01-17

    Assessment of sleep in mice currently requires initial implantation of chronic electrodes for assessment of electroencephalogram (EEG) and electromyogram (EMG) followed by time to recover from surgery. Hence, it is not ideal for high-throughput screening. To address this deficiency, a method of assessment of sleep and wakefulness in mice has been developed based on assessment of activity/inactivity either by digital video analysis or by breaking infrared beams in the mouse cage. It is based on the algorithm that any episode of continuous inactivity of > or =40 s is predicted to be sleep. The method gives excellent agreement in C57BL/6J male mice with simultaneous assessment of sleep by EEG/EMG recording. The average agreement over 8,640 10-s epochs in 24 h is 92% (n = 7 mice) with agreement in individual mice being 88-94%. Average EEG/EMG determined sleep per 2-h interval across the day was 59.4 min. The estimated mean difference (bias) per 2-h interval between inactivity-defined sleep and EEG/EMG-defined sleep was only 1.0 min (95% confidence interval for mean bias -0.06 to +2.6 min). The standard deviation of differences (precision) was 7.5 min per 2-h interval with 95% limits of agreement ranging from -13.7 to +15.7 min. Although bias significantly varied by time of day (P = 0.0007), the magnitude of time-of-day differences was not large (average bias during lights on and lights off was +5.0 and -3.0 min per 2-h interval, respectively). This method has applications in chemical mutagenesis and for studies of molecular changes in brain with sleep/wakefulness.

  11. Change of brown coal oxidation kinetic characteristics by promoting additives appending in the form of copper salts

    NASA Astrophysics Data System (ADS)

    Larionov, K. B.; Mishakov, I. V.; Gromov, A. A.; Zenkov, A. V.

    2017-11-01

    Process of brown coal oxidation with 5%wt content of copper-salt additives of various nature (Cu (NO3)2, CuSO4 and Cu(CH3COO)2) was studied. The experiment has been performed by thermogravimetric analysis at a heating rate of 2.5°C/min to a maximum temperature of 600°C in the air. Analytical evaluation of oxidation process kinetic characteristics has been conducted based on the results of TGA. It has been established that addition of initiating agents leads to significant reduction in the initial ignition temperature of coal (ΔTi = 15÷40°C), shortening of the sample warm-up time to the ignition point (Δte = 6÷12 min) and reduction of the sample burning time (Δtf = 40÷54 min). The following series of additives activity affecting ignition temperature of coals has been established: Cu(CH3COO)2 > Cu(NO3)2 > CuSO4. Additionally, the opposite can be said about the effect of additives on residence time of the sample in its combustion area (CuSO4 > Cu(NO3)2 > Cu(CH3COO)2). According to mass spectrometric analysis, presence of NOx, SO2, CO2 (intense peaks at 190÷290°C) was recorded in oxidation products of modified samples, which is explained by partial or complete decomposition of salts.

  12. Factor analysis and predictive validity of microcomputer-based tests

    NASA Technical Reports Server (NTRS)

    Kennedy, R. S.; Baltzley, D. R.; Turnage, J. J.; Jones, M. B.

    1989-01-01

    11 tests were selected from two microcomputer-based performance test batteries because previously these tests exhibited rapid stability (less than 10 min, of practice) and high retest reliability efficiencies (r greater than 0.707 for each 3 min. of testing). The battery was administered three times to each of 108 college students (48 men and 60 women) and a factor analysis was performed. Two of the three identified factors appear to be related to information processing ("encoding" and "throughput/decoding"), and the third named an "output/speed" factor. The spatial, memory, and verbal tests loaded on the "encoding" factor and included Grammatical Reasoning, Pattern Comparison, Continuous Recall, and Matrix Rotation. The "throughput/decoding" tests included perceptual/numerical tests like Math Processing, Code Substitution, and Pattern Comparison. The output speed factor was identified by Tapping and Reaction Time tests. The Wonderlic Personnel Test was group administered before the first and after the last administration of the performance tests. The multiple Rs in the total sample between combined Wonderlic as a criterion and less than 5 min. of microcomputer testing on Grammatical Reasoning and Math Processing as predictors ranged between 0.41 and 0.52 on the three test administrations. Based on these results, the authors recommend a core battery which, if time permits, would consist of two tests from each factor. Such a battery is now known to permit stable, reliable, and efficient assessment.

  13. Effectiveness of different final irrigation protocols in removing debris in flattened root canals.

    PubMed

    Nadalin, Michele Regina; Perez, Danyel Elias da Cruz; Vansan, Luiz Pascoal; Paschoala, Cristina; Souza-Neto, Manoel Damião; Saquy, Paulo César

    2009-01-01

    This study evaluated in vitro the capacity of debris removal from the apical third of flattened root canals, using different final irrigation protocols. Thirty human mandibular central incisors with a mesiodistal flattened root were prepared using rotary instrumentation by Endo-Flare 25.12 and Hero 642 30.06, 35.02, 40.02 files, irrigated with 2 mL of 1% NaOCl after each file. The specimens were randomly distributed into 5 groups according to the final irrigation of root canals: Group I: 10 mL of distilled water (control), Group II: 10 mL of 1% NaOCl for 8 min, Group III: 2 mL of 1% NaOCl for 2 min (repeated 4 times), Group IV: 10 mL of 2.5% NaOCl for 8 min, and Group V: 10 mL of 2.5% NaOCl for 2 min (repeated 4 times). The apical thirds of the specimens were subjected to histological processing and 6-microm cross-sections were obtained and stained with hematoxylin-eosin. The specimens were examined under optical microscopy at x40 magnification and the images were subjected to morphometric analysis using the Scion image-analysis software. The total area of root canal and the area with debris were measured in square millimeters. Analysis of variance showed no statistically significant difference (p>0.05) among the groups GI (2.39 +/- 3.59), GII (2.91 +/- 2.21), GIII (0.73 +/- 1.36), GIV (0.95 +/- 0.84) and GV (0.51 +/- 0.22). In conclusion, the final irrigation protocols evaluated in this study using the Luer syringe presented similar performance in the removal of debris from the apical third of flattened root canals.

  14. Quantification of steviol glycosides in food products, Stevia leaves and formulations by planar chromatography, including proof of absence for steviol and isosteviol.

    PubMed

    Wald, Julian P; Morlock, Gertrud E

    2017-07-14

    Steviol glycosides may degrade in food products under certain processing and storage conditions. Hence, a method was developed that separated in the same chromatographic run seven important steviol glycosides, and additionally as a sum parameter, their reported breakdown products steviol and isosteviol. Through derivatizations with the 2-naphthol and the primuline reagent, the detection was selective and inexpensive. In case needed, the baseline separation of steviol and isosteviol was also demonstrated after a plate cut and subsequent short development (two-step method). The HPTLC method was robust with regard to varying sample matrix loads, as the stationary phase was used only once. A high sample throughput was achieved, i.e. 23 separations were performed in parallel on one plate. The total analysis time took 1h (30min application, 15min separation and 15min derivatization/densitometry) leading to a calculated analysis time of 2.6min per sample. The solvent consumption was 8mL in total (0.4mL per analysis). HPTLC-ESI-MS was employed for confirmation of the results obtained. Mass spectra were recorded only from the zones of interest, and not from matrix or background, leading to decisive advantages, such as less need for MS cleaning. The optimized HPTLC method was shown to effectively support quality control, as marketed samples may be falsified with cheaper synthetic sweeteners, which was also demonstrated in this study. The accuracy of the densitometric quantification in HPTLC was considered as high, as standards and samples were separated on fresh adsorbent and detected simultaneously under identical conditions, which minimized the influence of errors. Finally, the Aliivibrio fischeri bioassay was employed to obtain information on bioactive compounds in Stevia leaf extracts. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Sleeping Pill Administration Time and Patient Subjective Satisfaction.

    PubMed

    Chung, Seockhoon; Youn, Soyoung; Yi, Kikyoung; Park, Boram; Lee, Suyeon

    2016-01-01

    Taking hypnotic agents 30 min before bedtime is the usual suggested administration time, but some patients report dissatisfaction with their sleeping pills. We investigated whether the timing of sleeping pill administration influences patient subjective satisfaction with these drugs. One hundred twelve patients with primary insomnia currently taking benzodiazepine or nonbenzodiazepine gamma-aminobutyric acid (GABA) agonists as sleeping pills were selected. The time of administration for their sleeping pills, bedtime, sleep onset time, and wake up time were obtained from their medical records. Subjects were also categorized into satisfied or dissatisfied groups. Hypnotic agents administration time (p < 0.001) and bedtime (p < 0.001), but not sleep onset or wake up time, occurred later in the night in the satisfied group. The durations from administration of pills to sleep onset (33.6 ± 20.7 min) and to wake up time (7.2 ± 1.2 h) were significantly shorter in the satisfied group when compared to the dissatisfied group (135.9 ± 73.4 min and 9.3 ± 1.5 h for time to sleep onset and wake up, respectively). Logistic regression analysis revealed that patient subjective satisfaction with hypnotic agents could be predicted by a short duration from administration of pills to sleep onset (odds ratio = 0.01; 95% confidence interval [0.001-0.09]) and a short duration from administration of pills to wake up time (0.53; [0.31-0.89], F = 49.9, p < 0.001). Taking sleeping pills at a later time and a shorter interval between pill administration and wake up time may increase patient subjective satisfaction with hypnotic agents. We propose that physicians advise patients to take sleeping pills approximately 7 h before their usual getting-out-of-bed time instead of the current standard of 30 min before bedtime. © 2016 American Academy of Sleep Medicine.

  16. Fast and comprehensive analysis of secondary metabolites in cocoa products using ultra high-performance liquid chromatography directly after pressurized liquid extraction.

    PubMed

    Damm, Irina; Enger, Eileen; Chrubasik-Hausmann, Sigrun; Schieber, Andreas; Zimmermann, Benno F

    2016-08-01

    Fast methods for the extraction and analysis of various secondary metabolites from cocoa products were developed and optimized regarding speed and separation efficiency. Extraction by pressurized liquid extraction is automated and the extracts are analyzed by rapid reversed-phase ultra high-performance liquid chromatography and normal-phase high-performance liquid chromatography methods. After extraction, no further sample treatment is required before chromatographic analysis. The analytes comprise monomeric and oligomeric flavanols, flavonols, methylxanthins, N-phenylpropenoyl amino acids, and phenolic acids. Polyphenols and N-phenylpropenoyl amino acids are separated in a single run of 33 min, procyanidins are analyzed by normal-phase high-performance liquid chromatography within 16 min, and methylxanthins require only 6 min total run time. A fourth method is suitable for phenolic acids, but only protocatechuic acid was found in relevant quantities. The optimized methods were validated and applied to 27 dark chocolates, one milk chocolate, two cocoa powders and two food supplements based on cocoa extract. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Year-long continuous personal exposure to PM 2.5 recorded by a fast responding portable nephelometer

    NASA Astrophysics Data System (ADS)

    Braniš, Martin; Kolomazníková, Jana

    2010-08-01

    Personal exposure to particulate matter of aerodynamic diameter under 2.5 μm (PM 2.5) was monitored using a DustTrak nephelometer. The battery-operated unit, worn by an adult individual for a period of approximately one year, logged integrated average PM 2.5 concentrations over 5 min intervals. A detailed time-activity diary was used to record the experimental subject's movement and the microenvironments visited. Altogether 239 days covering all the months (except April) were available for the analysis. In total, 60 463 acceptable 5-min averages were obtained. The dataset was divided into 7 indoor and 4 outdoor microenvironments. Of the total time, 84% was spent indoors, 10.9% outdoors and 5.1% in transport. The indoor 5-min PM 2.5 average was higher (55.7 μg m -3) than the outdoor value (49.8 μg m -3). The highest 5-min PM 2.5 average concentration was detected in restaurant microenvironments (1103 μg m -3), the second highest 5-min average concentration was recorded in indoor spaces heated by stoves burning solid fuels (420 μg m -3). The lowest 5-min mean aerosol concentrations were detected outdoors in rural/natural environments (25 μg m -3) and indoors at the monitored person's home (36 μg m -3). Outdoor and indoor concentrations of PM 2.5 measured by the nephelometer at home and during movement in the vicinity of the experimental subject's home were compared with those of the nearest fixed-site monitor of the national air quality monitoring network. The high correlation coefficient (0.78) between the personal and fixed-site monitor aerosol concentrations suggested that fixed-site monitor data can be used as proxies for personal exposure in residential and some other microenvironments. Collocated measurements with a reference method (β-attenuation) showed a non-linear systematic bias of the light-scattering method, limiting the use of direct concentration readings for exact exposure analysis.

  18. Assessing the impact of total extracorporeal circulation on hemodynamics in an ovine fetal model.

    PubMed

    Xiao, Fei; Zhuang, Jian; Zhou, Cheng-Bin; Chen, Ji-Mei; Cen, Jian-Zheng; Xu, Gang; Wen, Shu-Sheng

    2017-09-01

    The present study aimed to evaluate the impact of total extracorporeal circulation on hemodynamics and placental function in an ovine fetal model. Mid-term ovine fetuses (n=6) underwent extracorporeal circulation (30 min), cardioplegic arrest (20 min) and monitoring (120 min). The ascending aorta and umbilical cords of the fetuses were occluded during the bypass and an extracorporeal membrane oxygenator was used as the oxygen source. Biventricular intracardiac pressures, echocardiographic data, blood gas levels and placental function variables were recorded, and statistical analysis was performed using the repeated-measure analysis of variance test. The data indicated that fetal heart rate and blood pressure at 30, 60, 90 and 120 min following the bypass were stable relative to pre-arrest baseline (pre-bypass) values (P>0.05). However, end diastolic pressures in the ovine right ventricles post-bypass were significantly increased at 30, 60, 90 and 120 min relative to pre-bypass pressures (P<0.05). The pulsatility index also increased at 30 min post-bypass relative to the pre-bypass score (0.91±0.06 vs. 0.61±0.14; P=0.007). The mean resistivity index at all time points post-bypass was consistent with the pre-bypass score (P>0.05), while the mean Tei index values for the left and right ventricles post-bypass were significantly higher at all time points relative to pre-bypass values (P<0.05). The pre-bypass fetal blood pH, SaO 2 , base excess and lactate values were maintained during arrest (P>0.05). Fetal hemodynamics and placental function additionally remained stable for up to 2 h upon reperfusion following total extracorporeal circulation and cardioplegic arrest. Collectively these data suggest that the reproducible ovine fetal model may be useful in the evaluation of fetal cardiac surgery.

  19. Imaging human intrasynaptic dopamine release by IV cocaine and amphetamine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wong, D.F.; Hong, C.; Yokoi, F.

    1995-05-01

    Intrasynaptic dopamine (DA) release was measured with C-11 Raclopride (RAC) PET in 15 human subjects with two psychostimulant drugs, IV cocaine or IV amphetamine (AMPH). Eleven cocaine users received IV saline then cocaine with high specific activity (SA) tracer RAC by IV bolus. To determine the optimal timing of drug administration, subjects received 48mg cocaine at 0 min.(1 subject), 4 min.(3 subjects) or 10 min.(7 subjects) post injection (mpi). One received 32mg at 4 and 16mg at 10 mpi. In a separate paradigm, the effect of AMPH not only on the binding of Hi SA but also on the receptormore » density (B{sub max}) using Hi SA and low SA was examined. Four normals received 2 pairs of Hi SA and Low SA RAC PET scans, each pair separated by 1 week to estimate 2 B{sub max}`s, one affected by AMPH. Before the 2nd pair, 0.3mg/kg IV AMPH was given in the times corresponding to the AMPH times for the 1s B{sub max} measurement. All were scanned on a GE 4096WB+PET with 50 frames over 90 min with radial arterial plasma sampling and HPLC metabolite correction. Neuropsychological-endocrine testing was done concurrently. All subjects had a marked psychophysiological response for cocaine or AMPH (less with Low SA RAC). However, evidence of substantial DA release was not consistent with IV cocaine nor correlated with any timing of cocaine vs. RAC, except for an overall trend for RAC reduction with cocaine. The % change in k{sub 3}/k{sub 4} by graphical analysis ranged from +10 to -21%, with similar changes by other methods of quantification, such as k{sub 3}/k{sub 4} constrained to cerebellar K{sub 1}/k{sub 2}, and simple tissue ratios comparisons. IV AMPH showed DA release (19% {plus_minus} 2 (SEM) decrease) in all Hi SA RAC (k{sub 3}/k{sub 4}) by graphical analysis. The calculation of B{sub max} in putamen using Scatchard analysis (baseline B{sub max}29{plus_minus}2) showed 12 to 28% decreases following AMPH.« less

  20. Cyclodextrin-modified MEKC for enantioseparation of hexaconazole, penconazole, and myclobutanil.

    PubMed

    Wan Ibrahim, Wan Aini; Hermawan, Dadan; Sanagi, M Marsin; Aboul-Enein, Hassan Y

    2009-02-01

    A CD-modified micellar EKC (CD-MEKC) method with 2-hydroxypropyl-gamma-CD (HP-gamma-CD) as chiral selector for the enantioseparation of three chiral triazole fungicides, namely hexaconazole, penconazole, and myclobutanil, is reported for the first time. Simultaneous enantioseparation of the three triazole fungicides was successfully achieved using a CD-MEKC system containing 40 mM HP-gamma-CD and 50 mM SDS in 25 mM phosphate buffer (pH 3.0) solution with resolutions (R(s)) greater than 1.60, peak efficiencies (N) greater than 200,000 for all enantiomers and an analysis time within 15 min compared to 36 min as previously reported using sulfated-beta-CD.

  1. Improving on-time surgical starts: the impact of implementing pre-OR timeouts and performance pay.

    PubMed

    Martin, Luke; Langell, John

    2017-11-01

    Operating room (OR) time is expensive. Underutilized OR time negatively impacts efficiency and is an unnecessary cost for hospitals. The purpose of this study was to evaluate the impact of a pre-OR timeout and performance pay incentive on the frequency of on-time, first surgical starts. At a single Veterans Affairs Medical Center, we implemented a pre-OR timeout in the form of a safety-briefing checklist and a modest performance pay incentive for on-time starts (>90% compliance) for attending surgeons. Data were collected on all first-start cases beginning before implementation in 2008 and continued through 2015. Each year, an average of 960 first starts occurred across nine surgical divisions. Before implementation of either the timeout or pay incentive, only 15% of cases started on time, and by 2015, greater than 72% were on time (P < 0.001). Over the study period, there were significant improvements in on-time starts (P = 0.01), of delays <15 min (P = 0.01), and of delays 16 to 30 min (P = 0.04). The trends for delays of 31 to 60 min or >60 min were not significant (P = 0.31; P = 0.81). Assuming a loss of 7 min per case for delays <15 min and 20 min per case for delays of 16 to 30 min, the total OR time saved from implementing these measures was 37,556 min. At an estimated cost of $20/min, gross savings from this project were $751,120. Implementation of a pre-OR timeout and performance pay for on-time starts significantly improves OR utilization and reduces unnecessary costs. Published by Elsevier Inc.

  2. Uncertainty analysis of gas flow measurements using clearance-sealed piston provers in the range from 0.0012 g min-1 to 60 g min-1

    NASA Astrophysics Data System (ADS)

    Bobovnik, G.; Kutin, J.; Bajsić, I.

    2016-08-01

    This paper deals with an uncertainty analysis of gas flow measurements using a compact, high-speed, clearance-sealed realization of a piston prover. A detailed methodology for the uncertainty analysis, covering the components due to the gas density, dimensional and time measurements, the leakage flow, the density correction factor and the repeatability, is presented. The paper also deals with the selection of the isothermal and adiabatic measurement models, the treatment of the leakage flow and discusses the need for averaging multiple consecutive readings of the piston prover. The analysis is prepared for the flow range (50 000:1) covered by the three interchangeable flow cells. The results show that using the adiabatic measurement model and averaging the multiple readings, the estimated expanded measurement uncertainty of the gas mass flow rate is less than 0.15% in the flow range above 0.012 g min-1, whereas it increases for lower mass flow rates due to the leakage flow related effects. At the upper end of the measuring range, using the adiabatic instead of the isothermal measurement model, as well as averaging multiple readings, proves important.

  3. Insights into the Sulfur Mineralogy of Martian Soil at Rocknest, Gale Crater, Enabled by Evolved Gas Analyses

    NASA Technical Reports Server (NTRS)

    McAdam, A.; Franz, H.; Archer, P., Jr.; Freissinet, C.; Sutter, B.; Glavin, D.; Eigenbrode, J.; Bower, H.; Stern, J.; Mchaffy, P.; hide

    2013-01-01

    The first solid samples analysed by the Chemistry and Mineralogy (CheMin) instrument and Sample Analysis at Mars (SAM) instrument suite on the Mars Science Laboratory (MSL) consisted of < 150 m fines sieved from aeolian bedform material at a site named Rocknest. All four samples of this material analyzed by SAM s evolved gas analysis mass spectrometry (EGA-MS) released H2O, CO2, O2, and SO2 (Fig. 1), as well as H2S and possibly NO. This is the first time evolved SO2 (and evolved H2S) has been detected from thermal analysis of martian materials. The identity of these evolved gases and temperature (T) of evolution can support mineral detection by CheMin and place constraints on trace volatile-bearing phases present below the CheMin detection limit or difficult to characterize with XRD (e.g., X-ray amorphous phases). Constraints on phases responsible for evolved CO2 and O2 are detailed elsewhere [1,2,3]. Here, we focus on potential constraints on phases that evolved SO2, H2S, and H2O during thermal analysis.

  4. Hyperoxia and Hypoxic Hypoxia Effects on Simple and Choice Reaction Times.

    PubMed

    Dart, Todd; Gallo, Megan; Beer, Jeremy; Fischer, Joseph; Morgan, Thomas; Pilmanis, Andrew

    2017-12-01

    Effects of exposure to hyperoxia (PiO2 > 105 mmHg), normoxia (PiO2 95-105 mmHg) and hypoxia (PiO2 < 95 mmHg) on simple and choice reaction performance tasks were evaluated. Ten subjects performed simple and choice reaction time tests (SRT and CRT, respectively) at ground level for 40 min (20 min normoxic, 20 min hyperoxic, randomly assigned), 3048 m (10,000 ft) for 75 min (15 min hyperoxic, 60 min hypoxic), 4572 m (15,000 ft) for 60 min (15 min hyperoxic, 45 min hypoxic), and 6096 m (20,000 ft) for 35 min (15 min hyperoxic, 20 min hypoxic). SRT and CRT tests were also conducted at ground level 1 h after normoxic rest (recovery) to assess any recovery time effect on these psychomotor tasks. Total response time (TRT) significantly increased by 15 ms to 25 ms at all three altitudes for both the SRT and CRT tasks. At and below 4572 m, the performance changes were gradual over the duration of the exposures, whereas at 6096 m these changes were immediate. After 1 h, no performance decrement was measured. There was no statistical evidence that ground-level performance on these tasks was improved in hyperoxic vs. normoxic conditions. Results suggest mild decrements in reaction time due to hypoxia may occur as low as 3048 m (10,000 ft) while hyperoxia showed no positive effect on accuracy or reaction time at ground level or higher when performing simple and choice psychomotor reaction tasks.Dart T, Gallo M, Beer J, Fischer J, Morgan T, Pilmanis A. Hyperoxia and hypoxic hypoxia effects on simple and choice reaction times. Aerosp Med Hum Perform. 2017; 88(12):1073-1080.

  5. Temporal changes in geographic disparities in access to emergency heart attack and stroke care: are we any better today?

    PubMed

    Busingye, Doreen; Pedigo, Ashley; Odoi, Agricola

    2011-12-01

    The objective of this study was to investigate temporal changes in geographic access to emergency heart attack and stroke care. Network analysis was used to compute travel time to the nearest emergency room (ER), cardiac, and stroke centers in Middle Tennessee. Populations within 30, 60, and 90 min driving time to the nearest ER, cardiac and stroke centers were identified. There were improvements in timely access to cardiac and stroke centers over the study period (1999-2010). There were significant (p<0.0001) increases in the proportion of the population with access to cardiac centers within 30 min from 29.4% (1999) to 62.4% (2009) while that for stroke changed from 5.4% (2004) to 46.1% (2010). Most (96%) of the population had access to an ER within 30 min from 1999 to 2010. Access to care has improved in the last decade but more still needs to be done to address disparities in rural communities. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Nonlinear analysis of gait kinematics to track changes in oxygen consumption in prolonged load carriage walking: a pilot study.

    PubMed

    Schiffman, Jeffrey M; Chelidze, David; Adams, Albert; Segala, David B; Hasselquist, Leif

    2009-09-18

    Linking human mechanical work to physiological work for the purpose of developing a model of physical fatigue is a complex problem that cannot be solved easily by conventional biomechanical analysis. The purpose of the study was to determine if two nonlinear analysis methods can address the fundamental issue of utilizing kinematic data to track oxygen consumption from a prolonged walking trial: we evaluated the effectiveness of dynamical systems and fractal analysis in this study. Further, we selected, oxygen consumption as a measure to represent the underlying physiological measure of fatigue. Three male US Army Soldier volunteers (means: 23.3 yr; 1.80 m; 77.3 kg) walked for 120 min at 1.34 m/s with a 40-kg load on a level treadmill. Gait kinematic data and oxygen consumption (VO(2)) data were collected over the 120-min period. For the fractal analysis, utilizing stride interval data, we calculated fractal dimension. For the dynamical systems analysis, kinematic angle time series were used to estimate phase space warping based features at uniform time intervals: smooth orthogonal decomposition (SOD) was used to extract slowly time-varying trends from these features. Estimated fractal dimensions showed no apparent trend or correlation with independently measured VO(2). While inter-individual difference did exist in the VO(2) data, dominant SOD time trends tracked and correlated with the VO(2) for all volunteers. Thus, dynamical systems analysis using gait kinematics may be suitable to develop a model to predict physiologic fatigue based on biomechanical work.

  7. New microwave-integrated Soxhlet extraction. An advantageous tool for the extraction of lipids from food products.

    PubMed

    Virot, Matthieu; Tomao, Valérie; Colnagui, Giulio; Visinoni, Franco; Chemat, Farid

    2007-12-07

    A new process of Soxhlet extraction assisted by microwave was designed and developed. The process is performed in four steps, which ensures complete, rapid and accurate extraction of the samples. A second-order central composite design (CCD) has been used to investigate the performance of the new device. The results provided by analysis of variance and Pareto chart, indicated that the extraction time was the most important factor followed by the leaching time. The response surface methodology allowed us to determine optimal conditions for olive oil extraction: 13 min of extraction time, 17 min of leaching time, and 720 W of irradiation power. The proposed process is suitable for lipids determination from food. Microwave-integrated Soxhlet (MIS) extraction has been compared with a conventional technique, Soxhlet extraction, for the extraction of oil from olives (Aglandau, Vaucluse, France). The oils extracted by MIS for 32 min were quantitatively (yield) and qualitatively (fatty acid composition) similar to those obtained by conventional Soxhlet extraction for 8 h. MIS is a green technology and appears as a good alternative for the extraction of fat and oils from food products.

  8. Optimization of a Solid-Phase Microextraction method for the Gas Chromatography-Mass Spectrometry analysis of blackberry (Rubus ulmifolius Schott) fruit volatiles.

    PubMed

    D'Agostino, M F; Sanz, J; Sanz, M L; Giuffrè, A M; Sicari, V; Soria, A C

    2015-07-01

    A Solid-Phase Microextraction method for the Gas Chromatography-Mass Spectrometry analysis of blackberry (Rubus sp.) volatiles has been fully optimized by means of a Box-Behnken experimental design. The optimized operating conditions (Carboxen/Polydimethylsiloxane fiber coating, 66°C, 20 min equilibrium time and 16 min extraction time) have been applied to the characterization for the first time of the volatile composition of Rubus ulmifolius Schott blackberries collected in Italy and Spain. A total of 74 volatiles of different functionality were identified; esters and aliphatic alcohols were the predominant classes in both sample types. Methylbutanal (2.02-25.70%), ethanol (9.84-68.21%), 2,3-butanedione (2.31-14.71%), trans-2-hexenal (0.49-17.49%), 3-hydroxy-2-butanone (0.08-7.39%), 1-hexanol (0.56-16.39%), 1-octanol (0.49-10.86%) and methylbutanoic acid (0.53-21.48%) were the major compounds in most blackberries analyzed. Stepwise multiple regression analysis of semiquantitative data showed that only two variables (ethyl decanoate and ethyl acetate) were necessary for a successful differentiation of blackberries according to their harvest location. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Post-exercise heart rate variability recovery: a time-frequency analysis.

    PubMed

    Peçanha, Tiago; de Paula-Ribeiro, Marcelle; Nasario-Junior, Olivassé; de Lima, Jorge Roberto Perrout

    2013-12-01

    Most studies investigating the effects of non-pharmacological interventions, such as physical training (PT), on cardiac autonomic control, assessed the HRV only in resting conditions. Recently, a new time-frequency mathematical approach based on the short-time Fourier transform (STFT) method has been validated for the assessment of HRV in non-stationary conditions such as the immediate post-exercise period. The aim of this study was to evaluate the effects of the PT on post-exercise cardiac autonomic control using the time-frequency STFT analysis of the HRV. Twenty-one healthy male volunteers participated in this study. The subjects were initially evaluated for their physical exercise/sport practice and allocated to groups of low physical training ((Low)PT, n = 13) or high physical training (H(igh)PT, n = 8). The post-exercise HRV was assessed by the STFT method, which provides the analysis of dynamic changes in the power of the low- and high-frequency spectral components (LF and HF, respectively) of the HRV during the whole recovery period. Greater LF (from the min 5 to 10) and HF (from the min 6 to 10) in the post-exercise period in the H(igh)PT compared to the (Low)PT group (P < 0.05) was observed. These results indicate that exercise training exerts beneficial effects on post-exercise cardiac autonomic control.

  10. Searching for the synergistic effect between aclidinium and formoterol: From bench to bedside.

    PubMed

    Cazzola, Mario; Calzetta, Luigino; Ora, Josuel; Puxeddu, Ermanno; Rogliani, Paola; Matera, Maria Gabriella

    2015-10-01

    Aim of our study was to understand if the interaction between aclidinium and formoterol administered at therapeutic doses leads to a synergistic rather than additive broncholytic effect. We tested the type of effect ex vivo on isolated human bronchi and then in vivo in COPD patients. The analysis of the interaction between aclidinium and formoterol in vitro was measured by applying the Unified Theory, whereas that in COPD patients was measured by applying the Bliss Independence criterion. Aclidinium and formoterol administered alone completely relaxed human isolated bronchial tissues sub-maximally pre-contracted with ACh in a concentration-dependent manner with similar potency (EC50: aclidinium 4.64 ± 0.78 nM, formoterol 2.71 ± 0.21), whereas the interaction of aclidinium plus formoterol produced moderate to strong synergism. Changes in FEV1 values showed that inhaled aclidinium and formoterol induced a significant and time-dependent bronchodilatory effect during the study time. The inhalation of aclidinium and formoterol in combination significantly anticipated at 5 min post-administration the bronchodilatory effect of FEV1, compared with the effect of drugs administered alone. There was a synergistic interaction for FEV1 at 5 min and from 120 min to 240 min post-inhalation, whereas from 30 min to 60 min post-administration the drug interaction was additive. This study shows that aclidinium and formoterol can produce a significant synergistic interaction that may have a role also in the clinic setting. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Spectral sensitivity of the photointrinsic iris in the red-eared slider turtle (Trachemys scripta elegans).

    PubMed

    Sipe, Grayson O; Dearworth, James R; Selvarajah, Brian P; Blaum, Justin F; Littlefield, Tory E; Fink, Deborah A; Casey, Corinne N; McDougal, David H

    2011-01-01

    Our goal in this study was to examine the red-eared slider turtle for a photomechanical response (PMR) and define its spectral sensitivity. Pupils of enucleated eyes constricted to light by ∼11%, which was one-third the response measured in alert behaving turtles at ∼33%. Rates of constriction in enucleated eyes that were measured by time constants (1.44-3.70 min) were similar to those measured in turtles at 1.97 min. Dilation recovery rates during dark adaptation for enucleated eyes were predicted using line equations and computed times for reaching maximum sizes between 26 and 44 min. Times were comparable to the measures in turtles where maximum pupil size occurred within 40 min and possessed a time constant of 12.78 min. Hill equations were used to derive irradiance threshold values from enucleated hemisected eyes and then plot a spectral sensitivity curve. The analysis of the slopes and maximum responses revealed contribution from at least two different photopigments, one with a peak at 410 nm and another with a peak at 480 nm. Fits by template equations suggest that contractions are triggered by multiple photopigments in the iris including an opsin-based visual pigment and some other novel photopigment, or a cryptochrome with an absorbance spectrum significantly different from that used in our model. In addition to being regulated by retinal feedback via parasympathetic nervous pathways, the results support that the iris musculature is photointrinsically responsive. In the turtle, the control of its direct pupillary light response (dPLR) includes photoreceptive mechanisms occurring both in its iris and in its retina. Copyright © 2010 Elsevier Ltd. All rights reserved.

  12. Ultra-Short-Term Heart Rate Variability is Sensitive to Training Effects in Team Sports Players.

    PubMed

    Nakamura, Fabio Y; Flatt, Andrew A; Pereira, Lucas A; Ramirez-Campillo, Rodrigo; Loturco, Irineu; Esco, Michael R

    2015-09-01

    The aim of this study was to test the possibility of the ultra-short-term lnRMSSD (measured in 1-min post-1-min stabilization period) to detect training induced adaptations in futsal players. Twenty-four elite futsal players underwent HRV assessments pre- and post-three or four weeks preseason training. From the 10-min HRV recording period, lnRMSSD was analyzed in the following time segments: 1) from 0-5 min (i.e., stabilization period); 2) from 0-1 min; 1-2 min; 2-3 min; 3-4 min; 4-5 min and; 3) from 5-10 min (i.e., criterion period). The lnRMSSD was almost certainly higher (100/00/00) using the magnitude-based inference in all periods at the post- moment. The correlation between changes in ultra-short-term lnRMSSD (i.e., 0-1 min; 1-2 min; 2-3 min; 3-4 min; 4-5 min) and lnRMSSDCriterion ranged between 0.45-0.75, with the highest value (p = 0.75; 90% CI: 0.55 - 0.85) found between ultra-short-term lnRMDSSD at 1-2 min and lnRMSSDCriterion. In conclusion, lnRMSSD determined in a short period of 1-min is sensitive to training induced changes in futsal players (based on the very large correlation to the criterion measure), and can be used to track cardiac autonomic adaptations. Key pointsThe ultra-short-term (1 min) natural log of the root-mean-square difference of successive normal RR intervals (lnRMSSD) is sensitive to training effects in futsal playersThe ultra-short-term lnRMSSD may simplify the assessment of the cardiac autonomic changes in the field compared to the traditional and lengthier (10 min duration) analysisCoaches are encouraged to implement the ultra-short-term heart rate variability in their routines to monitor team sports athletes.

  13. Ultra-Short-Term Heart Rate Variability is Sensitive to Training Effects in Team Sports Players

    PubMed Central

    Nakamura, Fabio Y.; Flatt, Andrew A.; Pereira, Lucas A.; Ramirez-Campillo, Rodrigo; Loturco, Irineu; Esco, Michael R.

    2015-01-01

    The aim of this study was to test the possibility of the ultra-short-term lnRMSSD (measured in 1-min post-1-min stabilization period) to detect training induced adaptations in futsal players. Twenty-four elite futsal players underwent HRV assessments pre- and post-three or four weeks preseason training. From the 10-min HRV recording period, lnRMSSD was analyzed in the following time segments: 1) from 0-5 min (i.e., stabilization period); 2) from 0-1 min; 1-2 min; 2-3 min; 3-4 min; 4-5 min and; 3) from 5-10 min (i.e., criterion period). The lnRMSSD was almost certainly higher (100/00/00) using the magnitude-based inference in all periods at the post- moment. The correlation between changes in ultra-short-term lnRMSSD (i.e., 0-1 min; 1-2 min; 2-3 min; 3-4 min; 4-5 min) and lnRMSSDCriterion ranged between 0.45-0.75, with the highest value (p = 0.75; 90% CI: 0.55 – 0.85) found between ultra-short-term lnRMDSSD at 1-2 min and lnRMSSDCriterion. In conclusion, lnRMSSD determined in a short period of 1-min is sensitive to training induced changes in futsal players (based on the very large correlation to the criterion measure), and can be used to track cardiac autonomic adaptations. Key points The ultra-short-term (1 min) natural log of the root-mean-square difference of successive normal RR intervals (lnRMSSD) is sensitive to training effects in futsal players The ultra-short-term lnRMSSD may simplify the assessment of the cardiac autonomic changes in the field compared to the traditional and lengthier (10 min duration) analysis Coaches are encouraged to implement the ultra-short-term heart rate variability in their routines to monitor team sports athletes PMID:26336347

  14. Finding the signal in the noise: Could social media be utilized for early hospital notification of multiple casualty events?

    PubMed Central

    Moore, Sara; Wakam, Glenn; Hubbard, Alan E.; Cohen, Mitchell J.

    2017-01-01

    Introduction Delayed notification and lack of early information hinder timely hospital based activations in large scale multiple casualty events. We hypothesized that Twitter real-time data would produce a unique and reproducible signal within minutes of multiple casualty events and we investigated the timing of the signal compared with other hospital disaster notification mechanisms. Methods Using disaster specific search terms, all relevant tweets from the event to 7 days post-event were analyzed for 5 recent US based multiple casualty events (Boston Bombing [BB], SF Plane Crash [SF], Napa Earthquake [NE], Sandy Hook [SH], and Marysville Shooting [MV]). Quantitative and qualitative analysis of tweet utilization were compared across events. Results Over 3.8 million tweets were analyzed (SH 1.8 m, BB 1.1m, SF 430k, MV 250k, NE 205k). Peak tweets per min ranged from 209–3326. The mean followers per tweeter ranged from 3382–9992 across events. Retweets were tweeted a mean of 82–564 times per event. Tweets occurred very rapidly for all events (<2 mins) and represented 1% of the total event specific tweets in a median of 13 minutes of the first 911 calls. A 200 tweets/min threshold was reached fastest with NE (2 min), BB (7 min), and SF (18 mins). If this threshold was utilized as a signaling mechanism to place local hospitals on standby for possible large scale events, in all case studies, this signal would have preceded patient arrival. Importantly, this threshold for signaling would also have preceded traditional disaster notification mechanisms in SF, NE, and simultaneous with BB and MV. Conclusions Social media data has demonstrated that this mechanism is a powerful, predictable, and potentially important resource for optimizing disaster response. Further investigated is warranted to assess the utility of prospective signally thresholds for hospital based activation. PMID:28982201

  15. [Deep brain recording and length of surgery in stereotactic and functional neurosurgery for movement disorders].

    PubMed

    Teijeiro, Juan; Macías, Raúl J; Maragoto, Carlos; García, Iván; Alvarez, Mario; Quintanal, Nelson E

    2014-01-01

    Our objectives were to study the length of multi-unit recordings (MURs) of brain activity in 20 years of movement disorder neurosurgeries and to determine the number of times in which it was necessary for the teams using single-unit recording (SUR) to explore all the electrode tracks in the simultaneously recorded sites (SRS). This was a retrospective descriptive statistical analysis of MUR length on 4,296 tracks in 952 surgeries. The exclusion criteria were: tracks with fewer than 5 recorded signals, tracks that had a signal length different from the habitual 2s, or there being unusual situations not related to the MUR, as well as the first 20 surgeries of each surgical target. This yielded a total of 3,448 tracks in 805 surgeries. We also determined the number of the total 952 surgeries in which all the tracks in the SURs of the SRS were explored. The mean and its confidence interval (P=.05) of time per MUR track were 5.49±0.16min in subthalamic nucleus surgery, 8.82±0.24min in the medial or internal globus pallidus) and 18.51±1.31min in the ventral intermediate nucleus of the thalamus. For the total sum of tracks per surgery, in 75% of cases the total time was less than 39min in subthalamic nucleus, almost 42min in the medial or internal globus pallidus and less than 1h and 17min in ventral intermediate nucleus of the thalamus. All the tracks in the SUR SRS were explored in only 4.2% of the surgeries. The impact of MUR on surgical time is acceptable for this guide in objective localization for surgical targets, without having to use several simultaneous electrodes (not all indispensable in most of the cases). Consequently, there is less risk for the patient. Copyright © 2013 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  16. Individual ball possession in soccer

    PubMed Central

    Hoernig, Martin

    2017-01-01

    This paper describes models for detecting individual and team ball possession in soccer based on position data. The types of ball possession are classified as Individual Ball Possession (IBC), Individual Ball Action (IBA), Individual Ball Control (IBC), Team Ball Possession (TBP), Team Ball Control (TBC) und Team Playmaking (TPM) according to different starting points and endpoints and the type of ball control involved. The machine learning approach used is able to determine how long the ball spends in the sphere of influence of a player based on the distance between the players and the ball together with their direction of motion, speed and the acceleration of the ball. The degree of ball control exhibited during this phase is classified based on the spatio-temporal configuration of the player controlling the ball, the ball itself and opposing players using a Bayesian network. The evaluation and application of this approach uses data from 60 matches in the German Bundesliga season of 2013/14, including 69,667 IBA intervals. The identification rate was F = .88 for IBA and F = .83 for IBP, and the classification rate for IBC was κ = .67. Match analysis showed the following mean values per match: TBP 56:04 ± 5:12 min, TPM 50:01 ± 7:05 min and TBC 17:49 ± 8:13 min. There were 836 ± 424 IBC intervals per match and their number was significantly reduced by -5.1% from the 1st to 2nd half. The analysis of ball possession at the player level indicates shortest accumulated IBC times for the central forwards (0:49 ± 0:43 min) and the longest for goalkeepers (1:38 ± 0:58 min), central defenders (1:38 ± 1:09 min) and central midfielders (1:27 ± 1:08 min). The results could improve performance analysis in soccer, help to detect match events automatically, and allow discernment of higher value tactical structures, which is based on individual ball possession. PMID:28692649

  17. Optimizing Cold Water Immersion for Exercise-Induced Hyperthermia: A Meta-analysis.

    PubMed

    Zhang, Yang; Davis, Jon-Kyle; Casa, Douglas J; Bishop, Phillip A

    2015-11-01

    Cold water immersion (CWI) provides rapid cooling in events of exertional heat stroke. Optimal procedures for CWI in the field are not well established. This meta-analysis aimed to provide structured analysis of the effectiveness of CWI on the cooling rate in healthy adults subjected to exercise-induced hyperthermia. An electronic search (December 2014) was conducted using the PubMed and Web of Science. The mean difference of the cooling rate between CWI and passive recovery was calculated. Pooled analyses were based on a random-effects model. Sources of heterogeneity were identified through a mixed-effects model Q statistic. Inferential statistics aggregated the CWI cooling rate for extrapolation. Nineteen studies qualified for inclusion. Results demonstrate CWI elicited a significant effect: mean difference, 0.03°C·min(-1); 95% confidence interval, 0.03-0.04°C·min(-1). A conservative, observed estimate of the CWI cooling rate was 0.08°C·min(-1) across various conditions. CWI cooled individuals twice as fast as passive recovery. Subgroup analyses revealed that cooling was more effective (Q test P < 0.10) when preimmersion core temperature ≥38.6°C, immersion water temperature ≤10°C, ambient temperature ≥20°C, immersion duration ≤10 min, and using torso plus limbs immersion. There is insufficient evidence of effect using forearms/hands CWI for rapid cooling: mean difference, 0.01°C·min(-1); 95% confidence interval, -0.01°C·min(-1) to 0.04°C·min(-1). A combined data summary, pertaining to 607 subjects from 29 relevant studies, was presented for referencing the weighted cooling rate and recovery time, aiming for practitioners to better plan emergency procedures. An optimal procedure for yielding high cooling rates is proposed. Using prompt vigorous CWI should be encouraged for treating exercise-induced hyperthermia whenever possible, using cold water temperature (approximately 10°C) and maximizing body surface contact (whole-body immersion).

  18. Cumulative lactate and hospital mortality in ICU patients

    PubMed Central

    2013-01-01

    Background Both hyperlactatemia and persistence of hyperlactatemia have been associated with bad outcome. We compared lactate and lactate-derived variables in outcome prediction. Methods Retrospective observational study. Case records from 2,251 consecutive intensive care unit (ICU) patients admitted between 2001 and 2007 were analyzed. Baseline characteristics, all lactate measurements, and in-hospital mortality were recorded. The time integral of arterial blood lactate levels above the upper normal threshold of 2.2 mmol/L (lactate-time-integral), maximum lactate (max-lactate), and time-to-first-normalization were calculated. Survivors and nonsurvivors were compared and receiver operating characteristic (ROC) analysis were applied. Results A total of 20,755 lactate measurements were analyzed. Data are srpehown as median [interquartile range]. In nonsurvivors (n = 405) lactate-time-integral (192 [0–1881] min·mmol/L) and time-to-first normalization (44.0 [0–427] min) were higher than in hospital survivors (n = 1846; 0 [0–134] min·mmol/L and 0 [0–75] min, respectively; all p < 0.001). Normalization of lactate <6 hours after ICU admission revealed better survival compared with normalization of lactate >6 hours (mortality 16.6% vs. 24.4%; p < 0.001). AUC of ROC curves to predict in-hospital mortality was the largest for max-lactate, whereas it was not different among all other lactate derived variables (all p > 0.05). The area under the ROC curves for admission lactate and lactate-time-integral was not different (p = 0.36). Conclusions Hyperlactatemia is associated with in-hospital mortality in a heterogeneous ICU population. In our patients, lactate peak values predicted in-hospital mortality equally well as lactate-time-integral of arterial blood lactate levels above the upper normal threshold. PMID:23446002

  19. [Controlled evaluation of a high-resolution three-dimensional magnetic detector system (3D-MAGMA) as a proof of concept - examination of healthy volunteers before and after application of Metoclopramide (MCP)].

    PubMed

    Jacob, V Y P; Stallmach, A; Felber, J

    2016-06-01

    Changes in gastric and small bowel motility are a common clinical problem. Currently diagnostic options are limited because each method harbors certain disadvantages. It has been shown that the high-resolution three-dimensional magnetic detector system 3D-MAGMA is capable of reliably measuring gastric and small intestine motor activity. This system allows precise localization of a small magnetic marker and determination of its three-dimensional orientation inside a human body. The aim of the current study was to determine if 3D-MAGMA is reliably able to detect changes in gastric and small bowel motility under controlled conditions. MCP was used as a well known prokinetic agent to shorten the gastric and small bowel passage. 8 healthy volunteers (fasting) underwent motility testing of the stomach and small bowel by 3D-MAGMA with and without administration of MCP (10 mg orally). Among other data the time the capsule needed to pass through the stomach and the duodenum and the time the capsule needed to pass through the first 50 cm of the jejunum were recorded. The retention time of the capsule in the stomach under physiological conditions was 49.1 minutes (median; min. 18 min; max. 88.8 min). The median time the capsule needed to pass through the duodenum was 13.8 minutes (median; min. 1.7 min; max. 24.8 min). The time the capsule needed to pass through the first 50 cm of the jejunum under physiological conditions was 33.0 minutes (median; min. 20.2 min; max. 67.2 min). The retention time of the capsule in the stomach decreased significantly after administration of MCP to 20.9 minutes (median; min. 1.7 min; max. 62.8 min; p = 0.008). The time the capsule needed to pass through the duodenum was also reduced to 7.1 minutes (median; min. 3.1 min; max. 18.3 min; p = 0.055). The time the capsule needed to pass through the first 50 cm of the jejunum was also reduced to 21.7 minutes (median; min. 10.7 min; max. 31.2 min; p = 0.069). 3D-MAGMA is able to accurately detect changes in gastric and small bowel motility. Its clinical use appears conceivable especially in patients with diseases that have impact on gastric and small bowel motility. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Analysis of high-resolution foreign exchange data of USD-JPY for 13 years

    NASA Astrophysics Data System (ADS)

    Mizuno, Takayuki; Kurihara, Shoko; Takayasu, Misako; Takayasu, Hideki

    2003-06-01

    We analyze high-resolution foreign exchange data consisting of 20 million data points of USD-JPY for 13 years to report firm statistical laws in distributions and correlations of exchange rate fluctuations. A conditional probability density analysis clearly shows the existence of trend-following movements at time scale of 8-ticks, about 1 min.

  1. Stability of binary and ternary model oil-field particle suspensions: a multivariate analysis approach.

    PubMed

    Dudásová, Dorota; Rune Flåten, Geir; Sjöblom, Johan; Øye, Gisle

    2009-09-15

    The transmission profiles of one- to three-component particle suspension mixtures were analyzed by multivariate methods such as principal component analysis (PCA) and partial least-squares regression (PLS). The particles mimic the solids present in oil-field-produced water. Kaolin and silica represent solids of reservoir origin, whereas FeS is the product of bacterial metabolic activities, and Fe(3)O(4) corrosion product (e.g., from pipelines). All particles were coated with crude oil surface active components to imitate particles in real systems. The effects of different variables (concentration, temperature, and coating) on the suspension stability were studied with Turbiscan LAb(Expert). The transmission profiles over 75 min represent the overall water quality, while the transmission during the first 15.5 min gives information for suspension behavior during a representative time period for the hold time in the separator. The behavior of the mixed particle suspensions was compared to that of the single particle suspensions and models describing the systems were built. The findings are summarized as follows: silica seems to dominate the mixture properties in the binary suspensions toward enhanced separation. For 75 min, temperature and concentration are the most significant, while for 15.5 min, concentration is the only significant variable. Models for prediction of transmission spectra from run parameters as well as particle type from transmission profiles (inverse calibration) give a reasonable description of the relationships. In ternary particle mixtures, silica is not dominant and for 75 min, the significant variables for mixture (temperature and coating) are more similar to single kaolin and FeS/Fe(3)O(4). On the other hand, for 15.5 min, the coating is the most significant and this is similar to one for silica (at 15.5 min). The model for prediction of transmission spectra from run parameters gives good estimates of the transmission profiles. Although the model for prediction of particle type from transmission parameters is able to predict some particles, further improvement is required before all particles are consistently correctly classified. Cross-validation was done for both models and estimation errors are reported.

  2. Kinetic Modeling of the Tau PET Tracer 18F-AV-1451 in Human Healthy Volunteers and Alzheimer Disease Subjects.

    PubMed

    Barret, Olivier; Alagille, David; Sanabria, Sandra; Comley, Robert A; Weimer, Robby M; Borroni, Edilio; Mintun, Mark; Seneca, Nicholas; Papin, Caroline; Morley, Thomas; Marek, Ken; Seibyl, John P; Tamagnan, Gilles D; Jennings, Danna

    2017-07-01

    18 F-AV-1451 is currently the most widely used of several experimental tau PET tracers. The objective of this study was to evaluate 18 F-AV-1451 binding with full kinetic analysis using a metabolite-corrected arterial input function and to compare parameters derived from kinetic analysis with SUV ratio (SUVR) calculated over different imaging time intervals. Methods: 18 F-AV-1451 PET brain imaging was completed in 16 subjects: 4 young healthy volunteers (YHV), 4 aged healthy volunteers (AHV), and 8 Alzheimer disease (AD) subjects. Subjects were imaged for 3.5 h, with arterial blood samples obtained throughout. PET data were analyzed using plasma and reference tissue-based methods to estimate the distribution volume, binding potential (BP ND ), and SUVR. BP ND and SUVR were calculated using the cerebellar cortex as a reference region and were compared across the different methods and across the 3 groups (YHV, AHV, and AD). Results: AD demonstrated increased 18 F-AV-1451 retention compared with YHV and AHV based on both invasive and noninvasive analyses in cortical regions in which paired helical filament tau accumulation is expected in AD. A correlation of R 2 > 0.93 was found between BP ND (130 min) and SUVR-1 at all time intervals. Cortical SUVR curves reached a relative plateau around 1.0-1.2 for YHV and AHV by approximately 50 min, but increased in AD by up to approximately 20% at 110-130 min and approximately 30% at 160-180 min relative to 80-100 min. Distribution volume (130 min) was lower by 30%-35% in the YHV than AHV. Conclusion: Our data suggest that although 18 F-AV-1451 SUVR curves do not reach a plateau and are still increasing in AD, an SUVR calculated over an imaging window of 80-100 min (as currently used in clinical studies) provides estimates of paired helical filament tau burden in good correlation with BP ND , whereas SUVR sensitivity to regional cerebral blood changes needs further investigation. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  3. Smartphone transmission of electrocardiography images to reduce time of cardiac catheterization laboratory activation.

    PubMed

    Chao, Chun-Chieh; Chen, Yi-Chun; Shih, Chun-Ming; Hou, Sen-Kuang; Seethala, Raghu R; Aisiku, Imoigele P; Huang, Chuan-Chin; Hou, Peter C; Kao, Wei-Fong

    2018-06-01

    This retrospective study evaluated the use of a smartphone application to facilitate communication between the emergency physician (EP) and the interventional cardiologist in order to minimize the time to cardiac catheterization laboratory (CCL) activation and time to percutaneous coronary intervention (PCI). We retrospectively collected pertinent time-points in the management of patients diagnosed with STEMI in the emergency department and their outcome. The primary outcome was the reduction in the time from ECG interpretation to CCL activation after the implementation of a smartphone application. A total of 84 patients were enrolled. Patients' electrocardiography (ECG) were described by traditional verbal communication via telephone (group 1, n = 40) and by additional smartphone transmission of ECG images to an interventional cardiologist (group 2, n = 44). Relevant time-points were recorded for analysis. The time from ECG interpretation to CCL activation was reduced from 28.3 ± 4.1 in group 1 to 17.6 ± 2.3 min in group 2 (p = 0.03). Similarly, the time from ECG interpretation to balloon inflation time (D2B) decreased from 93.1 to 73.4 min (p = 0.025). Comparing group 2 with group 1, the door to balloon (D2B) time improved to 90.4 ± 9.8 from 119.3 ± 16.3 min (p = 0.23), the proportion of patients with a D2B time less than 90 min increased to 70.5% from 52.5% (p = 0.09), and the mortality rate decreased to 2.2% from 12.5% (p = 0.07). The additional use of a smartphone application to transmit ECG information to interventional cardiologists by EPs facilitated communication and reduced the decision time to CCL activation and percutaneous intervention. Copyright © 2017. Published by Elsevier Taiwan LLC.

  4. Oxytocin and Cortisol Levels in Dog Owners and Their Dogs Are Associated with Behavioral Patterns: An Exploratory Study

    PubMed Central

    Petersson, Maria; Uvnäs-Moberg, Kerstin; Nilsson, Anne; Gustafson, Lise-Lotte; Hydbring-Sandberg, Eva; Handlin, Linda

    2017-01-01

    We have previously shown that dog–owner interaction results in increasing oxytocin levels in owners and dogs, decreasing cortisol levels in owners but increasing cortisol levels in dogs. The present study aimed to further investigate whether oxytocin and cortisol levels in the previously tested owners and dogs were associated with their behaviors during the interaction experiment. Ten female volunteer dog–owners and their male Labrador dogs participated in a 60 min interaction experiment with interaction taking place during 0–3 min and blood samples for analysis of oxytocin and cortisol were collected at 0, 1, 3, 5, 15, 30, and 60 min. The entire experiment was videotaped and the following variables were noted; the different types (stroking, scratching, patting and activating touch, i.e., scratching and patting combined) as well as the frequency of touch applied by the owner, the number of times the owner touched her dog, the dog’s positions and time spent in each position. Correlations were analyzed between the behavioral variables and basal oxytocin levels, maximum oxytocin levels, delta oxytocin levels, basal cortisol levels and cortisol levels at 15 min. Owners with low oxytocin levels before and during the interaction touched their dogs more frequently (0 min: Rs = -0.683, p = 0.042; oxytocin maximum: Rs = -0.783, p = 0.013). The lower the dogs’ oxytocin levels during the interaction, the more stroking they received (Rs = -0.717, p = 0.041). The more frequently activating touch was applied by the owner, the higher the dogs’ cortisol levels became (15 min: Rs = 0.661, p = 0.038). The higher the owners’ maximum oxytocin level the fewer position changes the dogs made (Rs = -0.817, p = 0.007) and the shorter time they spent sitting (Rs = -0.786, p = 0.036), whereas the higher the owners’ basal cortisol levels, the longer time the dogs spent standing (0 min: Rs = 0.683, p = 0.041). In conclusion, oxytocin and cortisol levels, both in dogs and in their owners, are associated with the way the owners interact with their dogs and also with behaviors caused by the interaction. PMID:29081760

  5. Bodrum-Kos (Turkey-Greece) Mw 6.6 earthquake and tsunami of 20 July 2017: a test for the Mediterranean tsunami warning system

    NASA Astrophysics Data System (ADS)

    Heidarzadeh, Mohammad; Necmioglu, Ocal; Ishibe, Takeo; Yalciner, Ahmet C.

    2017-12-01

    Various Tsunami Service Providers (TSPs) within the Mediterranean Basin supply tsunami warnings including CAT-INGV (Italy), KOERI-RETMC (Turkey), and NOA/HL-NTWC (Greece). The 20 July 2017 Bodrum-Kos (Turkey-Greece) earthquake (Mw 6.6) and tsunami provided an opportunity to assess the response from these TSPs. Although the Bodrum-Kos tsunami was moderate (e.g., runup of 1.9 m) with little damage to properties, it was the first noticeable tsunami in the Mediterranean Basin since the 21 May 2003 western Mediterranean tsunami. Tsunami waveform analysis revealed that the trough-to-crest height was 34.1 cm at the near-field tide gauge station of Bodrum (Turkey). Tsunami period band was 2-30 min with peak periods at 7-13 min. We proposed a source fault model for this tsunami with the length and width of 25 and 15 km and uniform slip of 0.4 m. Tsunami simulations using both nodal planes produced almost same results in terms of agreement between tsunami observations and simulations. Different TSPs provided tsunami warnings at 10 min (CAT-INGV), 19 min (KOERI-RETMC), and 18 min (NOA/HL-NTWC) after the earthquake origin time. Apart from CAT-INGV, whose initial Mw estimation differed 0.2 units with respect to the final value, the response from the other two TSPs came relatively late compared to the desired warning time of 10 min, given the difficulties for timely and accurate calculation of earthquake magnitude and tsunami impact assessment. It is argued that even if a warning time of 10 min was achieved, it might not have been sufficient for addressing near-field tsunami hazards. Despite considerable progress and achievements made within the upstream components of NEAMTWS (North East Atlantic, Mediterranean and Connected seas Tsunami Warning System), the experience from this moderate tsunami may highlight the need for improving operational capabilities of TSPs, but more importantly for effectively integrating civil protection authorities into NEAMTWS and strengthening tsunami education programs.

  6. Oxytocin and Cortisol Levels in Dog Owners and Their Dogs Are Associated with Behavioral Patterns: An Exploratory Study.

    PubMed

    Petersson, Maria; Uvnäs-Moberg, Kerstin; Nilsson, Anne; Gustafson, Lise-Lotte; Hydbring-Sandberg, Eva; Handlin, Linda

    2017-01-01

    We have previously shown that dog-owner interaction results in increasing oxytocin levels in owners and dogs, decreasing cortisol levels in owners but increasing cortisol levels in dogs. The present study aimed to further investigate whether oxytocin and cortisol levels in the previously tested owners and dogs were associated with their behaviors during the interaction experiment. Ten female volunteer dog-owners and their male Labrador dogs participated in a 60 min interaction experiment with interaction taking place during 0-3 min and blood samples for analysis of oxytocin and cortisol were collected at 0, 1, 3, 5, 15, 30, and 60 min. The entire experiment was videotaped and the following variables were noted; the different types (stroking, scratching, patting and activating touch, i.e., scratching and patting combined) as well as the frequency of touch applied by the owner, the number of times the owner touched her dog, the dog's positions and time spent in each position. Correlations were analyzed between the behavioral variables and basal oxytocin levels, maximum oxytocin levels, delta oxytocin levels, basal cortisol levels and cortisol levels at 15 min. Owners with low oxytocin levels before and during the interaction touched their dogs more frequently (0 min: R s = -0.683, p = 0.042; oxytocin maximum: R s = -0.783, p = 0.013). The lower the dogs' oxytocin levels during the interaction, the more stroking they received ( R s = -0.717, p = 0.041). The more frequently activating touch was applied by the owner, the higher the dogs' cortisol levels became (15 min: R s = 0.661, p = 0.038). The higher the owners' maximum oxytocin level the fewer position changes the dogs made ( R s = -0.817, p = 0.007) and the shorter time they spent sitting ( R s = -0.786, p = 0.036), whereas the higher the owners' basal cortisol levels, the longer time the dogs spent standing (0 min: R s = 0.683, p = 0.041). In conclusion, oxytocin and cortisol levels, both in dogs and in their owners, are associated with the way the owners interact with their dogs and also with behaviors caused by the interaction.

  7. Analysis of dextromethorphan and dextrorphan in decomposed skeletal tissues by microwave assisted extraction, microplate solid-phase extraction and gas chromatography- mass spectrometry (MAE-MPSPE-GCMS).

    PubMed

    Fraser, Candice D; Cornthwaite, Heather M; Watterson, James H

    2015-08-01

    Analysis of decomposed skeletal tissues for dextromethorphan (DXM) and dextrorphan (DXT) using microwave assisted extraction (MAE), microplate solid-phase extraction (MPSPE) and gas chromatography-mass spectrometry (GC-MS) is described. Rats (n = 3) received 100 mg/kg DXM (i.p.) and were euthanized by CO2 asphyxiation roughly 20 min post-dose. Remains decomposed to skeleton outdoors and vertebral bones were recovered, cleaned, and pulverized. Pulverized bone underwent MAE using methanol as an extraction solvent in a closed microwave system, followed by MPSPE and GC-MS. Analyte stability under MAE conditions was assessed and found to be stable for at least 60 min irradiation time. The majority (>90%) of each analyte was recovered after 15 min. The MPSPE-GCMS method was fit to a quadratic response (R(2)  > 0.99), over the concentration range 10-10 000 ng⋅mL(-1) , with coefficients of variation <20% in triplicate analysis. The MPSPE-GCMS method displayed a limit of detection of 10 ng⋅mL(-1) for both analytes. Following MAE for 60 min (80 °C, 1200 W), MPSPE-GCMS analysis of vertebral bone of DXM-exposed rats detected both analytes in all samples (DXM: 0.9-1.5 µg⋅g(-1) ; DXT: 0.5-1.8 µg⋅g(-1) ). Copyright © 2014 John Wiley & Sons, Ltd.

  8. A break-even analysis of major ear surgery.

    PubMed

    Wasson, J D; Phillips, J S

    2015-10-01

    To determine variables which affect cost and profit for major ear surgery and perform a break-even analysis. Retrospective financial analysis. UK teaching hospital. Patients who underwent major ear surgery under general anaesthesia performed by the senior author in main theatre over a 2-year period between dates of 07 September 2010 and 07 September 2012. Income, cost and profit for each major ear patient spell. Variables that affect major ear surgery profitability. Seventy-six patients met inclusion criteria. Wide variation in earnings, with a median net loss of £-1345.50 was observed. Income was relatively uniform across all patient spells; however, theatre time of major ear surgery at a cost of £953.24 per hour varied between patients and was the main determinant of cost and profit for the patient spell. Bivariate linear regression of earnings on theatre time identified 94% of variation in earnings was due to variation in theatre time (r = -0.969; P < 0.0001) and derived a break-even time for major ear surgery of 110.6 min. Theatre time was dependent on complexity of procedure and number of OPCS4 procedures performed, with a significant increase in theatre time when three or more procedures were performed during major ear surgery (P = 0.015). For major ear surgery to either break-even or return a profit, total theatre time should not exceed 110 min and 36 s. © 2015 John Wiley & Sons Ltd.

  9. Effect of an Antimicrobial Compound on Different Processes within the Oscillation of Min Proteins in E. coli Bacterial Cells

    NASA Astrophysics Data System (ADS)

    Giuliani, Maximiliano; Dutcher, John

    2013-03-01

    A key step in the life of a bacterium is its division into two daughter cells of equal size. This process is carefully controlled and regulated so that equal partitioning of the cellular machinery is obtained. In E. coli, this regulation is accomplished, in part, by the Min protein system. The Min proteins undergo an oscillation between the poles of rod-shaped E. coli bacteria. We use high magnification, time-resolved total internal reflection fluorescence microscopy to characterize the temporal distributions of different processes within the oscillation: the MinD-MinE interaction time, the residence time for membrane bound MinD, and the recruitment time for MinD to be observed at the opposite pole. We also characterize the change in each of these processes in the presence of the antimicrobial compound polymyxin B (PMB). We show that the times corresponding to the removal of MinD from one pole and the recruitment of MinD at the opposite pole are correlated. We explain this correlation through the existence of a concentration threshold. The effect of PMB on the concentration threshold is used to identify which process within the oscillation is most affected.

  10. Influence of various environmental parameters on sweat gland activity.

    PubMed

    McMullen, Roger L; Gillece, Tim; Lu, Guojin; Laura, Donna; Chen, Susan

    2013-01-01

    The choice of environmental conditions when conducting antiperspirant studies greatly affects the quantity of sweat output. Our initial goal in this work was to develop an in-house procedure to test the efficacy of antiperspirant products using replica techniques in combination with image analysis. To ameliorate the skin replica method, we conducted rheological studies using dynamic mechanical analysis of the replica formulation. In terms of sweat output quantification, our preliminary results revealed a considerable amount of variation using the replica technique, leading us to conduct more fundamental studies of the factors that influence sweating behavior and how to best design the experimental strategy. In accordance with the FDA's protocol for antiperspirant testing, we carried out gravimetric analyses of axillae sweating under a variety of environmental conditions including temperature and humidity control. Subjects were first acclimatized in an environmentally controlled room for 30 min, and then placed in a sauna for an additional 30 or 45 min, depending on which test we administered. In Test 1 (30 min total in the sauna), the first 10 min in the sauna was another equilibration period, followed by a 20 min sweat production stage. We monitored axillae sweating during the last 20 min in the sauna by gravimetric analysis. At time (t) = 30 min in the sauna, skin replicas were taken and later analyzed using imaging and image analysis techniques. Test 1 was carried out on over 25 subjects, both male and female, from various racial backgrounds. In Test 2, subjects spent 45 min in the sauna after the initial 30-min period in the environmental room. During the 45 min, we obtained gravimetric readings of absorbent pads placed in the axillae. We conducted studies at various temperature and relative humidity settings. We also studied the influence of several external parameters on sudoriferous activity. Test 2 was a range-finding experiment on two subjects to determine the optimized environmental conditions for the hot room procedure. In addition to the replica and gravimetric techniques, we also measured flux density to determine the onset of firing of sweat glands to ensure that our environmental preconditioning step (30 min in the environmental room) brought subjects to the point that their sweat glands were activated. Although flux density measurements are usually carried out to determine transepidermal water loss (TEWL), we found that they can be equally useful for monitoring the onset of sweat production. Thermal infrared imaging experiments were also carried out allowing us to generate full-body images of subjects containing anatomical thermal distribution data with high accuracy. Overall, we conclude that our in-house hot room procedure offers much potential as an effective and cost-efficient screening tool for narrowing copious antiperspirant formulations to a select few for expensive clinical evaluation.

  11. Recovery of dynamic balance after general anesthesia with sevoflurane in short-duration oral surgery.

    PubMed

    Fujisawa, Toshiaki; Miyamoto, Eriko; Takuma, Shigeru; Shibuya, Makiko; Kurozumi, Akihiro; Kimura, Yukifumi; Kamekura, Nobuhito; Fukushima, Kazuaki

    2009-01-01

    Recovery of dynamic balance, involving adjustment of the center of gravity, is essential for safe discharge on foot after ambulatory anesthesia. The purpose of this study was to assess the recovery of dynamic balance after general anesthesia with sevoflurane, using two computerized dynamic posturographies. Nine hospitalized patients undergoing oral surgery of less than 2 h duration under general anesthesia (air-oxygensevoflurane) were studied. A dynamic balance test, assessing the ability of postural control against unpredictable perturbation stimuli (Stability System; Biodex Medical), a walking analysis test using sheets with foot pressure sensors (Walk Way-MG1000; Anima), and two simple psychomotor function tests were performed before anesthesia (baseline), and 150 and 210 min after the emergence from anesthesia. Only the double-stance phase in the walking analysis test showed a significant difference between baseline and results at 150 min. None of the other variables showed any differences among results at baseline and at 150 and 210 min. The recovery times for dynamic balance and psychomotor function seem to be within 150 min after emergence from general anesthesia with sevoflurane in patients undergoing oral surgery of less than 2-h duration.

  12. Role of sugammadex in accelerating postoperative discharge: A meta-analysis.

    PubMed

    Carron, Michele; Zarantonello, Francesco; Lazzarotto, Nadia; Tellaroli, Paola; Ori, Carlo

    2017-06-01

    Sugammadex has been introduced for reversal of neuromuscular blockade (NMB) induced by rocuronium (or vecuronium). Although its efficacy and safety have been established, data are conflicting as to whether it accelerates discharge to the surgical ward compared with neostigmine, which is traditionally used for reversing NMB. The object of this systematic review and meta-analysis was to review the research comparing sugammadex and neostigmine in the context of patient discharge after general anesthesia. Systematic review and meta-analysis. University medical hospital. Five-hundred eighteen patients from six studies were included. A comprehensive search was conducted using PubMed, Web of Science, Google Scholar, and Cochrane Library electronic databases to identify randomized controlled trials written in English. Two reviewers independently selected the studies, extracted data regarding postoperative discharge, and assessed the trials' methodological quality and evidence level. Postoperative discharge time was determined from the operating room (OR) to the postanesthesia care unit (PACU) and from the PACU to the surgical ward. This study was conducted using PRISMA methodology. Time to discharge after NMB reversal with sugammadex or neostigmine. Compared with neostigmine, sugammadex was associated with a significantly faster discharge from the OR to the PACU (mean difference [MD]=22.14min, 95% CI (14.62, 29.67), P<0.0001, I 2 =0%) and from the PACU to the surgical ward (MD=16.95min, 95% CI (0.23, 33.67), P=0.0469, I 2 =98.4%). Similarly, discharge-readiness was shorter for sugammadex than for neostigmine from the OR to the PACU (MD=5.58min, 95% CI (3.03, 8.14), P≤0.0001, I 2 =0%). However, discharge-readiness was similar in both groups for patients moving from the PACU to the surgical ward (MD=-1.10min, 95% CI (-5.69, 3.50), P=0.6394, I 2 =25.3%). Results from this meta-analysis suggest that sugammadex accelerates postoperative discharge of patients after general anesthesia compared with neostigmine. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Rapid planar chromatographic analysis of 25 water-soluble dyes used as food additives.

    PubMed

    Morlock, Gertrud E; Oellig, Claudia

    2009-01-01

    A rapid planar chromatographic method for identification and quantification of 25 water-soluble dyes in food was developed. In a horizontal developing chamber, the chromatographic separation on silica gel 60F254 high-performance thin-layer chromatography plates took 12 min for 40 runs in parallel, using 8 mL ethyl acetate-methanol-water-acetic acid (65 + 23 + 11 + 1, v/v/v/v) mobile phase up to a migration distance of 50 mm. However, the total analysis time, inclusive of application and evaluation, took 60 min for 40 runs. Thus, the overall time/run can be calculated as 1.5 min with a solvent consumption of 200 microL. A sample throughput of 1000 runs/8 h day can be reached by switching between the working stations (application, development, and evaluation) in a 20 min interval, which triples the analysis throughput. Densitometry was performed by absorption measurement using the multiwavelength scan mode in the UV and visible ranges. Repeatabilities [relative standard deviation (RSD), 4 determinations] at the first or second calibration level showed precisions of mostly < or = 2.7%, ranging between 0.2 and 5.2%. Correlation coefficient values (R > or = 0.9987) and RSD values (< or = 4.2%) of the calibration curves were highly satisfactory using classical quantification. However, digital evaluation of the plate image was also used for quantification, which resulted in RSD values of the calibration curves of mostly < or = 3.0%, except for two < or = 6.0%. The method was applied for the analysis of some energy drinks and bakery ink formulations, directly applied after dilution. By recording of absorbance spectra in the visible range, the identities of the dyes found in the samples were ascertained by comparison with the respective standard bands (correlation coefficients > or = 0.9996). If necessary for confirmation, online mass spectra were recorded within a minute.

  14. Impact of the aspirated volume of fat tissue in the insulin resistance after liposuction.

    PubMed

    Oliveira, Sérgio de Souza; Cibantos, Jubert Sanches; Ripari, Wagner Targa; Aguilar-Nascimento, José Eduardo de

    2013-01-01

    To investigate insulin resistance imposed by liposuction, correlating its intensity with the extent of the operation. The sample consisted of 20 female patients without comorbidities, aged between 21 and 43 years, body mass index between 19 and 27 kg/m², undergoing liposuction alone or associated with breasts' prosthesis. We assessed insulin resistance at the beginning and end of the procedure by calculating the Homeostasis Model Assessment (HOMA-IR). The operative variables were length of liposuction, breast prosthesis time, body areas submitted to liposuction and total fat aspirated. The liposuction time was 94-278 min (mean = 174 min), duration of breast prosthesis 20-140 min (mean = 65 min) and total fat aspirated 680-4280 g (mean = 1778 g). Statistical analysis was performed by considering a division line of 1500 g of aspirated fat and there was a significantly increased insulin resistance by HOMA index greater in the group > 1500 g (123% increase) than in the group d" 1500 g (an increase of 53 %) from the baseline data (p = 0.02). Other operative variables showed no significant correlation. Insulin resistance shows significant increase in liposuction, and it is correlated to the volume of aspirated fat.

  15. Circular Stapler-Assisted Extraperitoneal Colostomy in Laparoscopic Abdominoperineal Resection: a Single Surgeon Experience.

    PubMed

    Zhang, Peng; Bai, Jie; Shuai, Xiaoming; Chang, Weilong; Gao, Jinbo; Liu, Xinghua; Wang, Guobin; Tao, Kaixiong

    2016-03-01

    Nowadays, laparoscopic abdominoperineal resection (LAPR) not only has the same oncologic safety of open surgery and but also has the common advantages of laparoscopic surgery. However, given the difficulty in operation and long operative time, laparoscopic extraperitoneal colostomy construction is rarely practiced and reported. In this study, we describe technique of extraperitoneal colostomy using circular stapler following LAPR and demonstrate its efficacy and safety. This is a retrospective analysis of prospectively maintained data of 42 patients who underwent LAPR with circular stapler-assisted extraperitoneal colostomy in our department between July 2011 and June 2014. The mean time for extraperitoneal colostomy construction was 25 min (18-33 min). The mean operative time, estimated blood loss, postoperative gastrointestinal function recovery time, and duration of postoperative hospital stay were 160 min (115-225 min), 45 ml (10-250 ml), 33 h (26-45 h), and 8.6 days (6-13 days), respectively; 4.8 % of the patients had postoperative short-term complications. There were no stenosis, prolapse, and parastomal hernia observed in follow-up period. At 6 months after operation, 26 patients (62 %) claimed to be satisfied with their postoperative stool habits, 29 patients (69 %) had sensation to defecate per stoma, and 11 (26.2 %) patients had the ability to defer defecation for solid or liquid stool per stoma. Circular stapler-assisted extraperitoneal colostomy is an easy, effective, and safe technique following LAPR and appears to minimize the occurrence of stomal complications and improve the quality of life for patients.

  16. The effects of a single session of spinal manipulation on strength and cortical drive in athletes.

    PubMed

    Christiansen, Thomas Lykke; Niazi, Imran Khan; Holt, Kelly; Nedergaard, Rasmus Wiberg; Duehr, Jens; Allen, Kathryn; Marshall, Paul; Türker, Kemal S; Hartvigsen, Jan; Haavik, Heidi

    2018-04-01

    The primary purpose of this study was to investigate whether a single session of spinal manipulation (SM) increases strength and cortical drive in the lower limb (soleus muscle) of elite Taekwondo athletes. Soleus-evoked V-waves, H-reflex and maximum voluntary contraction (MVC) of the plantar flexors were recorded from 11 elite Taekwondo athletes using a randomized controlled crossover design. Interventions were either SM or passive movement control. Outcomes were assessed at pre-intervention and at three post-intervention time periods (immediate post, post 30 min and post 60 min). A multifactorial repeated measures ANOVA was conducted to assess within and between group differences. Time and session were used as factors. A post hoc analysis was carried out, when an interactive effect was present. Significance was set at p ≤ 0.05. SM increased MVC force [F(3,30) = 5.95, p < 0.01], and V-waves [F(3,30) = 4.25, p = 0.01] over time compared to the control intervention. Between group differences were significant for all time periods (p < 0.05) except for the post60 force measurements (p = 0.07). A single session of SM increased muscle strength and corticospinal excitability to ankle plantar flexor muscles in elite Taekwondo athletes. The increased MVC force lasted for 30 min and the corticospinal excitability increase persisted for at least 60 min.

  17. Exploring Dental Providers’ Workflow in an Electronic Dental Record Environment

    PubMed Central

    Schwei, Kelsey M; Cooper, Ryan; Mahnke, Andrea N.; Ye, Zhan

    2016-01-01

    Summary Background A workflow is defined as a predefined set of work steps and partial ordering of these steps in any environment to achieve the expected outcome. Few studies have investigated the workflow of providers in a dental office. It is important to understand the interaction of dental providers with the existing technologies at point of care to assess breakdown in the workflow which could contribute to better technology designs. Objective The study objective was to assess electronic dental record (EDR) workflows using time and motion methodology in order to identify breakdowns and opportunities for process improvement. Methods A time and motion methodology was used to study the human-computer interaction and workflow of dental providers with an EDR in four dental centers at a large healthcare organization. A data collection tool was developed to capture the workflow of dental providers and staff while they interacted with an EDR during initial, planned, and emergency patient visits, and at the front desk. Qualitative and quantitative analysis was conducted on the observational data. Results Breakdowns in workflow were identified while posting charges, viewing radiographs, e-prescribing, and interacting with patient scheduler. EDR interaction time was significantly different between dentists and dental assistants (6:20 min vs. 10:57 min, p = 0.013) and between dentists and dental hygienists (6:20 min vs. 9:36 min, p = 0.003). Conclusions On average, a dentist spent far less time than dental assistants and dental hygienists in data recording within the EDR. PMID:27437058

  18. Chronotype, bed timing and total sleep time in seniors

    PubMed Central

    Monk, Timothy H.; Buysse, Daniel J.

    2014-01-01

    Many older adults (seniors) experience problems with getting enough sleep. Because of the link between sleep and circadian rhythms, changes in bedtime lead to changes in the amount of sleep obtained. Although primarily determined genetically, chronotype changes with advancing age towards a more morning-type (M-type) orientation. In a 2006 study, we have found a linear relationship, by which the earlier a senior’s bedtime, the more sleep she/he will obtain. The aim of this study was to see whether this relationship differs for M-type seniors, as compared to seniors outside the M-type category. Retired seniors (n = 954, 535 M, 410F, 65 years+, mean age 74.4 years) taking part in a telephone interview were divided into M-types and Other types (O-types) using the Composite Scale of Morningness (CSM). The relationship between bedtime and Total Sleep Time (TST), and between rise-time and TST, was tested using linear regression separately for M-types and O-types. For each participant, habitual bedtime, rise-time and total Sleep Time (TST) [after removing time spent in unwanted wakefulness] were obtained using a telephone version of the Sleep Timing Questionnaire (STQ). Both chronotype groups showed a significant linear relationship between bedtime and TST (p<0.001); with earlier bedtimes leading to more TST (M-type 5.6 min; O-type 4.4 min per 10 min change [slope difference p = 0.05]); and an opposite relationship between rise-time and TST with earlier rise-times leading to less TST (M-type 6.7 min; O-type 4.2 min per 10 min change [slope difference p 0.001]). M-types retired to bed 56 min earlier (p<0.001), awoke 93 min earlier (p<0.001) and obtained 23 min less TST (p<0.001) than O-types. In conclusion, both chronotypes showed TST to be related in a linear way to bedtime and rise-time; the overall shorter TST in M-types was due to them rising 93 min earlier, but only retiring to bed 56 min earlier than O-types; as well as having a steeper rise-time versus TST relationship. PMID:24517139

  19. Electrocardiogram frequency change by extracorporeal blood perfusion in a swine ventricular fibrillation model

    PubMed Central

    2013-01-01

    Background Extracorporeal cardiopulmonary resuscitation (ECPR) refers to the application of extracorporeal blood circulation with oxygenation as a resuscitation tool. The objective of this study is to observe the frequency component changes in the electrocardiogram (ECG) by ECPR during prolonged ventricular fibrillation (VF). Methods Six swine were prepared as a VF model. Extracorporeal blood circulation with a pulsatile blood pump and oxygenator was set up for the model. ECG signals were measured for 13 min during VF and analyzed using frequency analysis methods. The median frequency (MF), dominant frequency (DF), and amplitude spectrum area (AMSA) were calculated from a spectrogram obtained using short-time Fourier transform (STFT). Results MF decreased from 11 Hz at the start to 9 Hz at 2 min after VF and then increased to 11 Hz at 4.5 min after VF. DF started at 7 Hz and increased to 11 Hz within the first min and decreased to 9 Hz at 2 min, then increased to 12 Hz at 4.5 min after VF. Both frequency components decreased gradually from 4.5 min until 10 min after VF. After the oxygenated blood perfusion was initiated, both MF and DF increased remarkably and exceeded 12 and 14 Hz, respectively. Similarly, AMSA decreased gradually for the first 10 min, but increased remarkably and varied beyond 13 mV∙Hz after the oxygenated blood supply started. Remarkable frequency increases in ECG due to the oxygenated blood perfusion during ECPR were observed in the swine VF model. Conclusions The ECG frequency analysis during ECPR can give the resuscitation provider important information about the cardiac perfusion status and the appropriateness of the ECPR setup as well as the prediction of defibrillation success. PMID:24274395

  20. Cardiovascular, respiratory and sedative effects of intramuscular alfaxalone, butorphanol and dexmedetomidine compared with ketamine, butorphanol and dexmedetomidine in healthy cats.

    PubMed

    Cremer, Jeannette; Riccó, Carolina H

    2017-11-01

    Objectives The aim of the study was to evaluate the cardiorespiratory effects, quality of sedation and recovery of intramuscular alfaxalone-dexmedetomidine-butorphanol (ADB) and ketamine-dexmedetomidine-butorphanol (KDB), in cats. Methods Nine adult, healthy cats (6.63 ± 1.42 kg) were enrolled in a blinded, randomized, crossover experimental design. Cats were sedated twice intramuscularly, once with ADB (alfaxalone 1 mg/kg, dexmedetomidine 0.005 mg/kg, butorphanol 0.2 mg/kg), and once with KDB (ketamine 5 mg/kg, dexmedetomidine 0.005 mg/kg, butorphanol 0.2 mg/kg), in random order. Data collected included heart rate (HR), arterial blood pressure and blood gas analysis, respiratory rate, and sedation score. Analysis of variance with Bonferroni post-hoc correction was used for parametric data, and a Wilcoxon signed rank test was used for non-parametric data. Significance was set at P <0.05. Results Total sedation time was shorter for ADB (90.71 ± 15.12 mins vs 147.00 ± 47.75 mins). Peak sedation was observed within 15 mins in both groups. Quality of recovery was excellent in both groups. HR decreased over time in both groups. Diastolic and mean arterial pressure decreased over time for ADB, becoming significant after 30 mins. All cardiovascular variables were within the clinically acceptable range in both groups. Arterial partial pressure of oxygen was significantly decreased from baseline for KDB at all time points (73 ± 2.5 mmHg [9.7 ± 0.3 kPa] vs ADB 83 ± 2.6 mmHg [11 ± 0.3 kPa]). Hypoventilation was not observed. Conclusions and relevance Both protocols produced acceptable cardiovascular stability. Sedation and recovery quality were good, albeit sedation was shorter with ADB. Although oxygenation was better maintained in the ADB group, all sedated cats should receive oxygen supplementation.

  1. The very low-frequency band of heart rate variability represents the slow recovery component after a mental stress task.

    PubMed

    Usui, Harunobu; Nishida, Yusuke

    2017-01-01

    The very low-frequency (VLF) band of heart rate variability (HRV) has different characteristics compared with other HRV components. Here we investigated differences in HRV changes after a mental stress task. After the task, the high-frequency (HF) band and ratio of high- to low-frequency bands (LF/HF) immediately returned to baseline. We evaluated the characteristics of VLF band changes after a mental stress task. We hypothesized that the VLF band decreases during the Stroop color word task and there would be a delayed recovery for 2 h after the task (i.e., the VLF change would exhibit a "slow recovery"). Nineteen healthy, young subjects were instructed to rest for 10 min, followed by a Stroop color word task for 20 min. After the task, the subjects were instructed to rest for 120 min. For all subjects, R-R interval data were collected; analysis was performed for VLF, HF, and LF/HF ratio. HRV during the rest time and each 15-min interval of the recovery time were compared. An analysis of the covariance was performed to adjust for the HF band and LF/HF ratio as confounding variables of the VLF component. HF and VLF bands significantly decreased and the LF/HF ratio significantly increased during the task compared with those during rest time. During recovery, the VLF band was significantly decreased compared with the rest time. After the task, the HF band and LF/HF ratio immediately returned to baseline and were not significantly different from the resting values. After adjusting for HF and LF/HF ratio, the VLF band had significantly decreased compared with that during rest. The VLF band is the "slow recovery" component and the HF band and LF/HF ratio are the "quick recovery" components of HRV. This VLF characteristic may clarify the unexplained association of the VLF band in cardiovascular disease prevention.

  2. Optimization of collision/reaction gases for determination of 90Sr in atmospheric particulate matter by inductively coupled plasma tandem mass spectrometry after direct introduction of air via a gas-exchange device

    NASA Astrophysics Data System (ADS)

    Suzuki, Yoshinari; Ohara, Ryota; Matsunaga, Kirara

    2017-09-01

    Nuclear power plant accidents release radioactive strontium 90 (90Sr) into the environment. Monitoring of 90Sr, although important, is difficult and time consuming because it emits only beta radiation. We have developed a new analytical system that enables real-time analysis of 90Sr in atmospheric particulate matter with an analytical run time of only 10 min. Briefly, after passage of an air sample through an impactor, a small fraction of the sample is introduced into a gas-exchange device, where the air is replaced by Ar. Then the sample is directly introduced into an inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) system equipped with a collision/reaction cell to eliminate isobaric interferences on 90Sr from 90Zr+, 89Y1H+, and 90Y+. Experiments with various reaction gas conditions revealed that these interferences could be minimized under the following optimized conditions: 1.0 mL min- 1 O2, 10.0 mL min- 1 H2, and 1.0 mL min- 1 NH3. The estimated background equivalent concentration and estimated detection limit of the system were 9.7 × 10- 4 and 3.6 × 10- 4 ng m- 3, respectively, which are equivalent to 4.9 × 10- 6 and 1.8 × 10- 6 Bq cm- 3. Recoveries of Sr in PM2.5 measured by real-time analysis compared to those obtained by simultaneously collection on filter was 53 ± 23%, and using this recovery, the detection limit as PM2.5 was estimated to be 3.4 ± 1.5 × 10- 6 Bq cm- 3. That is, this system enabled detection of 90Sr at concentrations < 5 × 10- 6 Bq cm- 3 even considering the insufficient fusion/vaporization/ionization efficiency of Sr in PM2.5.

  3. ABOLISHING AND ESTABLISHING OPERATION ANALYSES OF SOCIAL ATTENTION AS POSITIVE REINFORCEMENT FOR PROBLEM BEHAVIOR

    PubMed Central

    McGinnis, Molly A; Houchins-Juárez, Nealetta; McDaniel, Jill L; Kennedy, Craig H

    2010-01-01

    Three participants whose problem behavior was maintained by contingent attention were exposed to 45-min presessions in which attention was withheld, provided on a fixed-time (FT) 15-s schedule, or provided on an FT 120-s schedule. Following each presession, participants were then tested in a 15-min session similar to the social attention condition of an analogue functional analysis. The results showed establishing operation conditions increased problem behavior during tests and that abolishing operation conditions decreased problem behavior during tests. PMID:20808502

  4. Abolishing and establishing operation analyses of social attention as positive reinforcement for problem behavior.

    PubMed

    McGinnis, Molly A; Houchins-Juárez, Nealetta; McDaniel, Jill L; Kennedy, Craig H

    2010-03-01

    Three participants whose problem behavior was maintained by contingent attention were exposed to 45-min presessions in which attention was withheld, provided on a fixed-time (FT) 15-s schedule, or provided on an FT 120-s schedule. Following each presession, participants were then tested in a 15-min session similar to the social attention condition of an analogue functional analysis. The results showed establishing operation conditions increased problem behavior during tests and that abolishing operation conditions decreased problem behavior during tests.

  5. Constellation analysis of an integrated AIS/remote sensing spaceborne system for ship detection

    NASA Astrophysics Data System (ADS)

    Graziano, Maria Daniela; D'Errico, Marco; Razzano, Elena

    2012-08-01

    A future system integrating data from remote sensing and upcoming AIS satellites is analyzed through the development of a novel design method for global, discontinuous coverage constellations. It is shown that 8 AIS satellites suffice to guarantee global coverage and a ship location update of 50 min if the spaceborne AIS receiver has a swath of 2800 nm. Furthermore, synergic utilization of COSMO/SkyMed and Radarsat-C data would provide a mean revisit time of 7 h, with AIS information available within 25 min from SAR data acquisition.

  6. Factors affecting match performance in professional Australian football.

    PubMed

    Sullivan, Courtney; Bilsborough, Johann C; Cianciosi, Michael; Hocking, Joel; Cordy, Justin T; Coutts, Aaron J

    2014-05-01

    To determine the physical activity measures and skill-performance characteristics that contribute to coaches' perception of performance and player performance rank in professional Australian Football (AF). Prospective, longitudinal. Physical activity profiles were assessed via microtechnology (GPS and accelerometer) from 40 professional AF players from the same team during 15 Australian Football League games. Skill-performance measure and player-rank scores (Champion Data Rank) were provided by a commercial statistical provider. The physical-performance variables, skill involvements, and individual player performance scores were expressed relative to playing time for each quarter. A stepwise multiple regression was used to examine the contribution of physical activity and skill involvements to coaches' perception of performance and player rank in AF. Stepwise multiple-regression analysis revealed that 42.2% of the variance in coaches' perception of a player's performance could be explained by the skill-performance characteristics (player rank/min, effective kicks/min, pressure points/min, handballs/min, and running bounces/ min), with a small contribution from physical activity measures (accelerations/min) (adjusted R2 = .422, F6,282 = 36.054, P < .001). Multiple regression also revealed that 66.4% of the adjusted variance in player rank could be explained by total disposals/min, effective kicks/min, pressure points/min, kick clangers/min, marks/min, speed (m/min), and peak speed (adjusted R2 = .664, F7,281 = 82.289, P < .001). Increased physical activity throughout a match (speed [m/min] β - 0.097 and peak speed β - 0.116) negatively affects player rank in AF. Skill performance rather than increased physical activity is more important to coaches' perception of performance and player rank in professional AF.

  7. Operating room efficiency improvement after implementation of a postoperative team assessment.

    PubMed

    Porta, Christopher R; Foster, Andrew; Causey, Marlin W; Cordier, Patricia; Ozbirn, Roger; Bolt, Stephen; Allison, Dennis; Rush, Robert

    2013-03-01

    Operating room time is highly resource intensive, and delays can be a source of lost revenue and surgeon frustration. Methods to decrease these delays are important not only for patient care, but to maximize operating room resource utilization. The purpose of this study was to determine the root cause of operating room delays in a standardized manner to help improve overall operating room efficiency. We performed a single-center prospective observational study analyzing operating room utilization and efficiency after implementing an executive-driven standardized postoperative team debriefing system from January 2010 to December 2010. A total of 11,342 procedures were performed over the 1-y study period (elective 86%, urgent 11%, and emergent 3%), with 1.3 million min of operating room time, 865,864 min of surgeon operative time (62.5%), and 162,958 min of anesthesia time (11.8%). Overall, the average operating room delay was 18 min and varied greatly based on the surgical specialty. The longest delays were due to need for radiology (40 min); other significant delays were due to supply issues (22.7 min), surgeon issues (18 min), nursing issues (14 min), and room turnover (14 min). Over the 1-y period, there was a decrease in mean delay duration, averaging a decrease in delay of 0.147 min/mo with an overall 9% decrease in the mean delay times. With regard to overall operating room utilization, there was a 39% decrease in overall un-utilized available OR time that was due to delays, improving efficiency by 2334 min (212 min/mo). During this study interval no sentinel events occurred in the operating room. A standardized postoperative debrief tracking system is highly beneficial in identifying and reducing overall operative delays and improving operating room utilization. Published by Elsevier Inc.

  8. Multiscale adaptive analysis of circadian rhythms and intradaily variability: Application to actigraphy time series in acute insomnia subjects

    PubMed Central

    Rivera, Ana Leonor; Toledo-Roy, Juan C.; Ellis, Jason; Angelova, Maia

    2017-01-01

    Circadian rhythms become less dominant and less regular with chronic-degenerative disease, such that to accurately assess these pathological conditions it is important to quantify not only periodic characteristics but also more irregular aspects of the corresponding time series. Novel data-adaptive techniques, such as singular spectrum analysis (SSA), allow for the decomposition of experimental time series, in a model-free way, into a trend, quasiperiodic components and noise fluctuations. We compared SSA with the traditional techniques of cosinor analysis and intradaily variability using 1-week continuous actigraphy data in young adults with acute insomnia and healthy age-matched controls. The findings suggest a small but significant delay in circadian components in the subjects with acute insomnia, i.e. a larger acrophase, and alterations in the day-to-day variability of acrophase and amplitude. The power of the ultradian components follows a fractal 1/f power law for controls, whereas for those with acute insomnia this power law breaks down because of an increased variability at the 90min time scale, reminiscent of Kleitman’s basic rest-activity (BRAC) cycles. This suggests that for healthy sleepers attention and activity can be sustained at whatever time scale required by circumstances, whereas for those with acute insomnia this capacity may be impaired and these individuals need to rest or switch activities in order to stay focused. Traditional methods of circadian rhythm analysis are unable to detect the more subtle effects of day-to-day variability and ultradian rhythm fragmentation at the specific 90min time scale. PMID:28753669

  9. A rapid method for the measurement of sulfur hexafluoride (SF6), trifluoromethyl sulfur pentafluoride (SF5CF3), and Halon 1211 (CF2ClBr) in hydrologic tracer studies

    USGS Publications Warehouse

    Busenberg, Eurybiades; Plummer, Niel

    2010-01-01

    A rapid headspace method for the simultaneous laboratory determination of intentionally introduced hydrologic tracers, sulfur hexafluoride (SF6), trifluoromethyl sulfur pentafluoride (SF5CF3), Halon 1211 (CF2ClBr), and other halocarbons in water and gases is described. The high sensitivity of the procedure allows for introduction of minimal tracer mass (a few grams) into hydrologic systems with a large dynamic range of analytical detection (dilutions to 1:108). Analysis times by gas chromatography with electron capture detector are less than 1 min for SF6; about 2 min for SF6 and SF5CF3; and 4 min for SF6, SF5CF3, and Halon 1211. Many samples can be rapidly collected, preserved in stoppered septum bottles, and analyzed at a later time in the laboratory. Examples are provided showing the effectiveness of the gas tracer test studies in varied hydrogeological settings.

  10. A rapid method for the measurement of sulfur hexafluoride (SF6), trifluoromethyl sulfur pentafluoride (SF5CF3), and Halon 1211 (CF2ClBr) in hydrologic tracer studies

    NASA Astrophysics Data System (ADS)

    Busenberg, Eurybiades; Plummer, L. Niel

    2010-11-01

    A rapid headspace method for the simultaneous laboratory determination of intentionally introduced hydrologic tracers, sulfur hexafluoride (SF6), trifluoromethyl sulfur pentafluoride (SF5CF3), Halon 1211 (CF2ClBr), and other halocarbons in water and gases is described. The high sensitivity of the procedure allows for introduction of minimal tracer mass (a few grams) into hydrologic systems with a large dynamic range of analytical detection (dilutions to 1:108). Analysis times by gas chromatography with electron capture detector are less than 1 min for SF6; about 2 min for SF6 and SF5CF3; and 4 min for SF6, SF5CF3, and Halon 1211. Many samples can be rapidly collected, preserved in stoppered septum bottles, and analyzed at a later time in the laboratory. Examples are provided showing the effectiveness of the gas tracer test studies in varied hydrogeological settings.

  11. Determination of ammonium ion by fluorometry or spectrophotometry after on-line derivatization with o-phthalaldehyde

    NASA Technical Reports Server (NTRS)

    Goyal, S. S.; Rains, D. W.; Huffaker, R. C.

    1988-01-01

    A fast, sensitive, simple, and highly reproducible method for routine assay of ammonium ion (NH4+) was developed by using HPLC equipment. The method is based on the reaction of NH4+ with o-phthalaldehyde (OPA) in the presence of 2-mercaptoethanol. After an on-line derivatization, the resulting NH4(+)-OPA product was quantified by using fluorometric or spectrophotometric detection. For fluorometric detection, the excitation and emission wavelengths were 410 and 470 nm, respectively. The spectrophotometric detection was made by measuring absorbance at 410 nm. Results on the effects of OPA-reagent composition and pH, reaction temperature, sample matrix, and linearity of the assay are presented. Even though it took about 2 min from the time of sample injection to the appearance of sample peak, sample injections could be overlapped at an interval of about 1 min. Thus, the actual time needed for analysis was about 1 min per assay. The method can be used in a fully automated mode by using an autosampler injector.

  12. Effects of dairy factory, milk casein content and titratable acidity on coagulation properties in Trentingrana dairy industry.

    PubMed

    Penasa, Mauro; Toffanin, Valentina; Cologna, Nicola; Cassandro, Martino; De Marchi, Massimo

    2016-05-01

    The objective of the present study was to investigate the effect of environmental factors, milk casein content and titratable acidity on milk coagulation properties (MCP) of samples routinely collected in the Trento province (northeast Italy) under field conditions. Rennet coagulation time (RCT, min), curd-firming time (k20, min) and curd firmness (a30, mm) were determined by Formagraph on 14 971 samples from 635 herds associated to 17 dairy factories. Besides MCP, fat, protein, and casein percentages, titratable acidity (TA), and somatic cell and bacterial counts were available. A standardised index of milk aptitude to coagulate (IAC) was derived using information of RCT and a30. An analysis of variance was conducted on MCP and IAC using a fixed effects linear model. Approximately 3% of milk samples did not form a curd within the testing time (30 min) and k20 was missing for 26% of milks. The percentage of samples without information on k20 largely differed among dairy factories (1·7-20·9%). Significant differences were estimated between the best and the worst dairy factory for RCT (-2 min), k20 (-1·2 min), a30 (+3·4 mm) and IAC (+2·6 points). Milk casein content and TA were important factors in explaining the variation of MCP and IAC, supporting the central role of these two traits on technological properties. The Trento province is heterogeneous in terms of dairy systems and this could explain the differences among dairy factories.

  13. Time-kill kinetic analysis of antimicrobial chemotherapy based on hydrogen peroxide photolysis against Streptococcus mutans biofilm.

    PubMed

    Shirato, Midori; Nakamura, Keisuke; Kanno, Taro; Lingström, Peter; Niwano, Yoshimi; Örtengren, Ulf

    2017-08-01

    A recently developed antimicrobial technique utilizing hydroxyl radicals generated by hydrogen peroxide (H 2 O 2 ) photolysis represents a promising new therapy for preventing and treating dental caries. The present study compared the antimicrobial time-kill kinetics of H 2 O 2 photolysis, conventional antiseptics, and antimicrobial photodynamic therapy (aPDT) against biofilm-forming Streptococcus mutans (cariogenic bacteria) grown on hydroxyapatite disks. H 2 O 2 photolysis was performed by irradiating the biofilm immersed in 3% H 2 O 2 with 365-nm light-emitting diode (LED) light at an irradiance of 1000mW/cm 2 for up to 1.5min. Antiseptic treatments consisted of 0.2% chlorhexidine gluconate, 0.5% povidone-iodine, and 3% H 2 O 2 . The biofilm was immersed in each antiseptic for up to 4min. aPDT was performed by irradiating the biofilm immersed in 100μM methylene blue or toluidine blue O with 655-nm laser light at 1000mW/cm 2 for up to 4min. Based on the time-kill assay, the decimal reduction value (D-value) of each treatment was determined. With a D-value of 0.06min, H 2 O 2 photolysis exhibited the highest bactericidal effect against biofilm-forming S. mutans. In contrast, antiseptics and aPDT exerted a slower bactericidal effect, with D-values of 0.9-2.7min. In conclusion, the antimicrobial technique based on H 2 O 2 photolysis using 365-nm LED represents a strong adjunctive chemotherapy for dental caries treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Excitation and desensitization of mouse rod photoreceptors in vivo following bright adapting light

    PubMed Central

    Kang Derwent, Jennifer J; Qtaishat, Nasser M; Pepperberg, David R

    2002-01-01

    Electroretinographic (ERG) methods were used to determine response properties of mouse rod photoreceptors in vivo following adapting illumination that produced a significant extent of rhodopsin bleaching. Bleaching levels prevailing at ∼10 min and ∼20 min after the adapting exposure were on average 14% and 9%, respectively, based on the analysis of visual cycle retinoids in the eye tissues. Recovery of the rod response to the adapting light was monitored by analysing the ERG a-wave response to a bright probe flash presented at varying times during dark adaptation. A paired-flash procedure, in which the probe flash was presented at defined times after a weak test flash of fixed strength, was used to determine sensitivity of the rod response to the test flash. Recovery of the response to the adapting light was 80% complete at 13.5 ± 3.0 min (mean ± s.d.; n = 7) after adapting light offset. The adapting light caused prolonged desensitization of the weak-flash response derived from paired-flash data. By comparison with results obtained in the absence of the adapting exposure, desensitization determined with a test-probe interval of 80 ms was ∼fourfold after 5 min of dark adaptation and ∼twofold after 20 min. The results indicate, for mouse rods in vivo, that the time scale for recovery of weak-flash sensitivity substantially exceeds that for the recovery of circulating current following significant rhodopsin bleaching. The lingering desensitization may reflect a reduced efficiency of signal transmission in the phototransduction cascade distinct from that due to residual excitation. PMID:12015430

  15. Covert checks by standardised patients of general practitioners' delivery of new periodic health examinations: clustered cross-sectional study from a consumer organisation

    PubMed Central

    Thaler, Kylie; Harris, Mark F

    2012-01-01

    Objective To assess if data collected by a consumer organisation are valid for a health service research study on physicians' performance in preventive care. To report first results of the analysis of physicians performance like consultation time and guideline adherence in history taking. Design Secondary data analysis of a clustered cross-sectional direct observation survey. Setting General practitioners (GPs) in Vienna, Austria, visited unannounced by mystery shoppers (incognito standardised patients (ISPs)). Participants 21 randomly selected GPs were visited by two different ISPs each. 40 observation protocols were realised. Main outcome measures Robustness of sampling and data collection by the consumer organisation. GPs consultation and waiting times, guideline adherence in history taking. Results The double stratified random sampling method was robust and representative for the private and contracted GPs mix of Vienna. The clinical scenarios presented by the ISPs were valid and believable, and no GP realised the ISPs were not genuine patients. The average consultation time was 46 min (95% CI 37 to 54 min). Waiting times differed more than consultation times between private and contracted GPs. No differences between private and contracted GPs in terms of adherence to the evidence-based guidelines regarding history taking including questions regarding alcohol use were found. According to the analysis, 20% of the GPs took a perfect history (95% CI 9% to 39%). Conclusions The analysis of secondary data collected by a consumer organisation was a valid method for drawing conclusions about GPs preventive practice. Initial results, like consultation times longer than anticipated, and the moderate quality of history taking encourage continuing the analysis on available clinical data. PMID:22872721

  16. Use of an operating microscope during spine surgery is associated with minor increases in operating room times and no increased risk of infection.

    PubMed

    Basques, Bryce A; Golinvaux, Nicholas S; Bohl, Daniel D; Yacob, Alem; Toy, Jason O; Varthi, Arya G; Grauer, Jonathan N

    2014-10-15

    Retrospective database review. To evaluate whether microscope use during spine procedures is associated with increased operating room times or increased risk of infection. Operating microscopes are commonly used in spine procedures. It is debated whether the use of an operating microscope increases operating room time or confers increased risk of infection. The American College of Surgeons National Surgical Quality Improvement Program database, which includes data from more than 370 participating hospitals, was used to identify patients undergoing elective spinal procedures with and without the use of an operating microscope for the years 2011 and 2012. Bivariate and multivariate linear regressions were used to test the association between microscope use and operating room times. Bivariate and multivariate logistic regressions were similarly conducted to test the association between microscope use and infection occurrence within 30 days of surgery. A total of 23,670 elective spine procedures were identified, of which 2226 (9.4%) used an operating microscope. The average patient age was 55.1±14.4 years. The average operative time (incision to closure) was 125.7±82.0 minutes.Microscope use was associated with minor increases in preoperative room time (+2.9 min, P=0.013), operative time (+13.2 min, P<0.001), and total room time (+18.6 min, P<0.001) on multivariate analysis.A total of 328 (1.4%) patients had an infection within 30 days of surgery. Multivariate analysis revealed no significant difference between the microscope and nonmicroscope groups for occurrence of any infection, superficial surgical site infection, deep surgical site infection, organ space infection, or sepsis/septic shock, regardless of surgery type. We did not find operating room times or infection risk to be significant deterrents for use of an operating microscope during spine surgery. 3.

  17. A prospective observational study comparing a physiological scoring system with time-based discharge criteria in pediatric ambulatory surgical patients.

    PubMed

    Armstrong, James; Forrest, Helen; Crawford, Mark W

    2015-10-01

    Discharge criteria based on physiological scoring systems can be used in the postanesthesia care unit (PACU) to fast-track patients after ambulatory surgery; however, studies comparing physiological scoring systems with traditional time-based discharge criteria are lacking. The purpose of this study was to compare PACU discharge readiness times using physiological vs time-based discharge criteria in pediatric ambulatory surgical patients. We recorded physiological observations from consecutive American Society of Anesthesiologists physical status I-III patients aged 1-18 yr who were admitted to the PACU after undergoing ambulatory surgery in a tertiary academic pediatric hospital. The physiological score was a combination of the Aldrete and Chung systems. Scores were recorded every 15 min starting upon arrival in the PACU. Patients were considered fit for discharge once they attained a score ≥12 (maximum score, 14), provided no score was zero, with the time to achieve a score ≥12 defining the criteria-based discharge (CBD) time. Patients were discharged from the PACU when both the CBD and the existing time-based discharge (TBD) criteria were met. The CBD and TBD data were compared using Kaplan-Meier and log-rank analysis. Observations from 506 children are presented. Median (interquartile range [IQR]) age was 5.5 [2.8-9.9] yr. Median [IQR] CBD and TBD PACU discharge readiness times were 30 [15-45] min and 60 [45-60] min, respectively. Analysis of Kaplan-Meier curves indicated a significant difference in discharge times using the different criteria (hazard ratio, 5.43; 95% confidence interval, 4.51 to 6.53; P < 0.001). All patients were discharged home without incident. This prospective study suggests that discharge decisions based on physiological criteria have the potential for significantly speeding the transit of children through the PACU, thereby enhancing PACU efficiency and resource utilization.

  18. [Efficacy of preoxygenation using tidal volume breathing: a comparison of Mapleson A, Bain's and Circle system].

    PubMed

    Arora, Suman; Gupta, Priyanka; Arya, Virender Kumar; Bhatia, Nidhi

    Efficacy of preoxygenation depends upon inspired oxygen concentration, its flow rate, breathing system configuration and patient characteristics. We hypothesized that in actual clinical scenario, where breathing circuit is not primed with 100% oxygen, patients may need more time to achieve EtO 2 ≥90%, and this duration may be different among various breathing systems. We thus studied the efficacy of preoxygenation using unprimed Mapleson A, Bain's and Circle system with tidal volume breathing at oxygen flow rates of 5L.min -1 and 10L.min -1 . Patients were randomly allocated into one of the six groups, wherein they were preoxygenated using either Mapleson A, Bain's or Circle system at O 2 flow rate of either 5L.min -1 or 10L.min -1 . The primary outcome measure of our study was the time taken to achieve EtO 2 ≥90% at 5 and 10L.min -1 flow rates. At oxygen flow rate of 5L.min -1 , time to reach EtO 2 ≥90% was significantly longer with Bain's system (3.7±0.67min) than Mapleson A and Circle system (2.9±0.6, 3.3±0.97min, respectively). However at oxygen flow rate of 10L.min -1 this time was significantly shorter and comparable among all the three breathing systems (2.33±0.38min with Mapleson, 2.59±0.50min with Bain's and 2.60±0.47min with Circle system). With spontaneous normal tidal volume breathing at oxygen flow rate of 5L.min -1 , Mapleson A can optimally preoxygenate patients within 3min while Bain's and Circle system require more time. However at O 2 flow rate of 10L.min -1 all the three breathing systems are capable of optimally preoxygenating the patients in less than 3min. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  19. One-day quantitative cross-sectional study of family information time in 90 intensive care units in France.

    PubMed

    Fassier, Thomas; Darmon, Michel; Laplace, Christian; Chevret, Sylvie; Schlemmer, Benoit; Pochard, Frédéric; Azoulay, Elie

    2007-01-01

    Providing family members with clear, honest, and timely information is a major task for intensive care unit physicians. Time spent informing families has been associated with effectiveness of information but has not been measured in specifically designed studies. To measure time spent informing families of intensive care unit patients. One-day cross-sectional study in 90 intensive care units in France. Clocked time spent by physicians informing the families of each of 951 patients hospitalized in the intensive care unit during a 24-hr period. Median family information time was 16 (interquartile range, 8-30) mins per patient, with 20% of the time spent explaining the diagnosis, 20% on explaining treatments, and 60% on explaining the prognosis. One third of the time was spent listening to family members. Multivariable analysis identified one factor associated with less information time (room with more than one bed) and seven factors associated with more information time, including five patient-related factors (surgery on the study day, higher Logistic Organ Dysfunction score, coma, mechanical ventilation, and worsening clinical status) and two family-related factors (first contact with family and interview with the spouse). Median information time was 20 (interquartile range, 10-39) mins when three factors were present and 106.5 (interquartile range, 103-110) mins when five were present. This study identifies factors associated with information time provided by critical care physicians to family members of critically ill patients. Whether information time correlates with communication difficulties or communication skills needs to be evaluated. Information time provided by residents and nurses should be studied.

  20. Geographic Access to US Neurocritical Care Units Registered with the Neurocritical Care Society

    PubMed Central

    Shutter, Lori A.; Branas, Charles C.; Adeoye, Opeolu; Albright, Karen C.; Carr, Brendan G.

    2018-01-01

    Background Neurocritical care provides multidisciplinary, specialized care to critically ill neurological patients, yet an understanding of the proportion of the population able to rapidly access specialized Neurocritical Care Units (NCUs) in the United States is currently unknown. We sought to quantify geographic access to NCUs by state, division, region, and for the US as a whole. In addition, we examined how mode of transportation (ground or air ambulance), and prehospital transport times affected population access to NCUs. Methods Data were obtained from the Neurocritical Care Society (NCS), US Census Bureau and the Atlas and Database of Air Medical Services. Empirically derived prehospital time intervals and validated models estimating prehospital ground and air travel times were used to calculate total prehospital times. A discrete total prehospital time interval was calculated for each small unit of geographic analysis (block group) and block group populations were summed to determine the proportion of Americans able to reach a NCU within discrete time intervals (45, 60, 75, and 90 min). Results are presented for different geographies and for different modes of prehospital transport (ground or air ambulance). Results There are 73 NCUs in the US using ground transportation alone, 12.8, 20.5, 27.4, and 32.6% of the US population are within 45, 60, 75, and 90 min of an NCU, respectively. Use of air ambulances increases access to 36.8, 50.4, 60, and 67.3 within 45, 60, 75, and 90 min, respectively. The Northeast has the highest access rates in the US using ground ambulances and for 45, 60, and 75 min transport times with the addition of air ambulances. At 90 min, the West has the highest access rate. The Southern region has the lowest ground and air access to NCUs access rates for all transport times. Conclusions Using NCUs registered with the NCS, current geographic access to NCUs is limited in the US, and geographic disparities in access to care exist. While additional NCUs may exist beyond those identified by the NCS database, we identify geographies with limited access to NCUs and offer a population-based planning perspective on the further development of the US neurocritical care system. PMID:22045246

  1. Single freeze per vein strategy with the second-generation cryoballoon for atrial fibrillation: a propensity score-matched study between 180- and 240-s application time in a large cohort of patients.

    PubMed

    De Regibus, Valentina; Abugattas, Juan-Pablo; Iacopino, Saverio; Mugnai, Giacomo; Storti, Cesare; Conte, Giulio; Auricchio, Angelo; Ströker, Erwin; Coutiño, Hugo-Enrique; Takarada, Ken; Salghetti, Francesca; Lusoc, Ian; Capulzini, Lucio; Brugada, Pedro; de Asmundis, Carlo; Chierchia, Gian-Battista

    2017-11-02

    The single-freeze strategy using the second-generation cryoballoon (CB-A, Arctic Front Advance, Medtronic, Minneapolis, MN, USA) has been reported to be as effective as the recommended double-freeze approach in several single-centre studies. In this retrospective, international, multicentre study, we compare the 3-min single-freeze strategy with the 4-min single-freeze strategy. Four hundred and thirty-two patients having undergone pulmonary vein isolation (PVI) by means of CB-A using a single-freeze strategy were considered for this analysis. A cohort of patients who were treated with a 3-min strategy (Group 1) was compared with a propensity score-matched cohort of patients who underwent a 4-min strategy (Group 2). Pulmonary vein isolation was successfully achieved in all the veins using the 28-mm CB-A. The procedural and fluoroscopy times were lower in Group 1 (67.8 ± 17 vs. 73.8 ± 26.3, P < 0.05; 14.9 ± 7.8 vs. 24.2 ± 10.6 min, P < 0.05). The most frequent complication was PNP, with no difference between the two groups (P = 0.67). After a mean follow-up of 13 ± 8 months, taking into consideration a blanking period of 3 months, 85.6% of patients in Group 1 and 87% of patients in Group 2 were free from arrhythmia recurrence at final follow-up (P = 0.67). There is no difference in acute success, rate of complications, and freedom from atrial fibrillation recurrences during the follow-up between 3-min and 4-min per vein freeze strategies. The procedural and fluoroscopy times were significantly shorter in 3-min per vein strategy. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For Permissions, please email: journals.permissions@oup.com.

  2. Changing from primary to secondary school highlights opportunities for school environment interventions aiming to increase physical activity and reduce sedentary behaviour: a longitudinal cohort study.

    PubMed

    Marks, Jennifer; Barnett, Lisa M; Strugnell, Claudia; Allender, Steven

    2015-05-08

    There is little empirical evidence of the impact of transition from primary to secondary school on obesity-related risk behaviour. The purpose of this study was to examine the effect of a change of school system on physical activity (PA) and sedentary behaviour in pre-early adolescents. Fifteen schools in Victoria, Australia were recruited at random from the bottom two strata of a five level socio-economic scale. In nine schools, students in year 6 primary school transitioned to a different school for year 7 secondary school, while in six schools (combined primary-secondary), students remained in the same school environment from year 6 to year 7. Time 1 (T1) measures were collected from students (N=245) in year 6 (age 11-13). Time 2 (T2) data were collected from 243 (99%) of the original student cohort when in year 7. PA and sedentary behaviour data were collected objectively (via ActiGraph accelerometer) and subjectively (via child self-report recall questionnaire). School environment data were collected via school staff survey. Change of behaviour analyses were conducted longitudinally i) for all students and ii) by change/no change of school. Mixed model regression analysis tested for behavioural interaction effects of changing/not changing school. Sixty-three percent (N=152) changed schools from T1 to T2. Across all students we observed declines in average daily moderate to vigorous physical activity (MVPA) (-4 min) and light PA (-23 min), and increases in average daily sedentary behaviour (16 min), weekday leisure screen time (17 min) and weekday homework screen time (25 min), all P<0.05. Compared to students who remained in the same school environment, students who changed school reported a greater reduction in PA intensity at recess and lunch, less likelihood to cycle to/from school, greater increase in weekday (41 mins) and weekend (45 mins) leisure screen time (P<0.05) and greater encouragement to participate in sport. School staff surveys identified that sport participation encouragement was greater in primary and combined primary-secondary than secondary schools (P<0.05). Transitioning from primary to secondary school negatively impacts on children's PA and sedentary behaviour, and has further compounding effects on behaviour type by changing school environments.

  3. The Effect of UVC Irradiation on the Mechanical Properties of Chitosan Membrane in Sterilization Process

    NASA Astrophysics Data System (ADS)

    Rupiasih, N. N.; Sumadiyasa, M.; Putra, I. K.

    2018-04-01

    The present study, we report about the effect of UVC irradiation on the mechanical properties of chitosan membrane in the sterilization process. The membrane used was chitosan membrane 2% which prepared by a casting method using chitosan as matrix and acetic acid 1% as a solvent. The UVC source used was germicidal ultraviolet (UVG) which widely used for sterilization purposes. Variation doses were done by the varying time of irradiation, e.g. 5 min, 15 min, 30 min, and 60 min. Those samples are named as S1, S2, S3, and S4, respectively. Chitosan membrane before irradiation namely S0 also used for comparative study. The effect of UVC irradiation on the mechanical properties of membranes has been examined by different techniques including FTIR, DMA, and the water uptake capability. The results showed that ultimate tensile strength (UTS) and moduli of elasticity (E) were increased by increasing the irradiation time. From FTIR analysis obtained that no new molecules were formed in irradiated membranes. The water uptakes capability of the membranes after irradiation was smaller compared with before irradiation, and among the irradiated membranes, the water uptake capabilities were increased by increasing the exposure time. These observations suggested that more care should be taken during the sterilization process and outdoor used of the membrane. The other side, the UVC irradiation can improve the mechanical properties of the membranes.

  4. [Relationship between physical activity and hemodynamic parameters in adults].

    PubMed

    Gómez-Sánchez, L; García-Ortiz, L; Recio-Rodríguez, J I; Patino-Alonso, M C; Agudo-Conde, C; Gómez-Marcos, M A

    2015-01-01

    To analyze the relationship between physical activity, as assessed by accelerometer, with central and peripheral augmentation index and carotid intima media thickness (IMT) in adults. This study analyzed 263 subjects who were included in the EVIDENT study. Physical activity was assessed during 7 days using the ActigraphGT3X accelerometer (counts/min). Carotid ultrasound was used to measure carotid IMT. The Sphygmo Cor System was used to measure central and peripheral augmentation index (CAIx and PAIx). Mean age 55.85±12 years; 59.30% female; 26.7 body mass index and blood pressure 120/77mmHg. Mean physician activity counts/min was 244.37 and 2.63±10.26min/day of vigorous or very vigorous activity. Physical activity showed an inverse correlation with PAIx (r=-0.179; P<.01) and vigorous activity day time with IMT(r=-0.174; P<.01), CAIx (r=-0.217; P<.01) and PAIx (r=-0.324; P<.01). After adjusting for confounding factors in the multiple regression analysis, the inverse association of CAIx with counts/min and the time spent in vigorous/very vigorous activity was maintained. The results suggest that both physical activity and time spent in vigorous or vigorous activity are associated with the central augmentation index in adults. Copyright © 2015 SEHLELHA. Published by Elsevier Espana. All rights reserved.

  5. A comparison of volume clamp method-based continuous noninvasive cardiac output (CNCO) measurement versus intermittent pulmonary artery thermodilution in postoperative cardiothoracic surgery patients.

    PubMed

    Wagner, Julia Y; Körner, Annmarie; Schulte-Uentrop, Leonie; Kubik, Mathias; Reichenspurner, Hermann; Kluge, Stefan; Reuter, Daniel A; Saugel, Bernd

    2018-04-01

    The CNAP technology (CNSystems Medizintechnik AG, Graz, Austria) allows continuous noninvasive arterial pressure waveform recording based on the volume clamp method and estimation of cardiac output (CO) by pulse contour analysis. We compared CNAP-derived CO measurements (CNCO) with intermittent invasive CO measurements (pulmonary artery catheter; PAC-CO) in postoperative cardiothoracic surgery patients. In 51 intensive care unit patients after cardiothoracic surgery, we measured PAC-CO (criterion standard) and CNCO at three different time points. We conducted two separate comparative analyses: (1) CNCO auto-calibrated to biometric patient data (CNCO bio ) versus PAC-CO and (2) CNCO calibrated to the first simultaneously measured PAC-CO value (CNCO cal ) versus PAC-CO. The agreement between the two methods was statistically assessed by Bland-Altman analysis and the percentage error. In a subgroup of patients, a passive leg raising maneuver was performed for clinical indications and we present the changes in PAC-CO and CNCO in four-quadrant plots (exclusion zone 0.5 L/min) in order to evaluate the trending ability of CNCO. The mean difference between CNCO bio and PAC-CO was +0.5 L/min (standard deviation ± 1.3 L/min; 95% limits of agreement -1.9 to +3.0 L/min). The percentage error was 49%. The concordance rate was 100%. For CNCOcal, the mean difference was -0.3 L/min (±0.5 L/min; -1.2 to +0.7 L/min) with a percentage error of 19%. In this clinical study in cardiothoracic surgery patients, CNCO cal showed good agreement when compared with PAC-CO. For CNCO bio , we observed a higher percentage error and good trending ability (concordance rate 100%).

  6. The acute physiological stress response to an emergency alarm and mobilization during the day and at night.

    PubMed

    Hall, Sarah J; Aisbett, Brad; Tait, Jamie L; Turner, Anne I; Ferguson, Sally A; Main, Luana C

    2016-01-01

    The purpose of this study was to investigate the acute physiological stress response to an emergency alarm and mobilization during the day and at night. Sixteen healthy males aged 25 ± 4 years (mean ± SD) spent four consecutive days and nights in a sleep laboratory. This research used a within-participants design with repeated measures for time, alarm condition (alarm or control), and trial (day or night). When an alarm sounded, participants were required to mobilize immediately. Saliva samples for cortisol analysis were collected 0 min, 15 min, 30 min, 45 min, 60 min, 90 min, and 120 min after mobilization, and at corresponding times in control conditions. Heart rate was measured continuously throughout the study. Heart rate was higher in the day (F(20,442) = 9.140, P < 0.001) and night (F(23,459) = 8.356, P < 0.001) alarm conditions compared to the respective control conditions. There was no difference in saliva cortisol between day alarm and day control conditions. Cortisol was higher (F(6,183) = 2.450, P < 0.001) following the night alarm and mobilization compared to the night control condition. The magnitude of difference in cortisol between night control and night alarm conditions was greater (F(6,174) = 4.071, P < 0.001) than the magnitude of difference between the day control and day alarm conditions. The augmented heart rate response to the day and night alarms supports previous observations in field settings. Variations in the cortisol responses between conditions across the day and night may relate to differences in participants' ability to interpret the alarm when sleeping versus when awake.

  7. The acute physiological stress response to an emergency alarm and mobilization during the day and at night

    PubMed Central

    Hall, Sarah J; Aisbett, Brad; Tait, Jamie L; Turner, Anne I; Ferguson, Sally A; Main, Luana C

    2016-01-01

    The purpose of this study was to investigate the acute physiological stress response to an emergency alarm and mobilization during the day and at night. Sixteen healthy males aged 25 ± 4 years (mean ± SD) spent four consecutive days and nights in a sleep laboratory. This research used a within-participants design with repeated measures for time, alarm condition (alarm or control), and trial (day or night). When an alarm sounded, participants were required to mobilize immediately. Saliva samples for cortisol analysis were collected 0 min, 15 min, 30 min, 45 min, 60 min, 90 min, and 120 min after mobilization, and at corresponding times in control conditions. Heart rate was measured continuously throughout the study. Heart rate was higher in the day (F20,442 = 9.140, P < 0.001) and night (F23,459 = 8.356, P < 0.001) alarm conditions compared to the respective control conditions. There was no difference in saliva cortisol between day alarm and day control conditions. Cortisol was higher (F6,183 = 2.450, P < 0.001) following the night alarm and mobilization compared to the night control condition. The magnitude of difference in cortisol between night control and night alarm conditions was greater (F6,174 = 4.071, P < 0.001) than the magnitude of difference between the day control and day alarm conditions. The augmented heart rate response to the day and night alarms supports previous observations in field settings. Variations in the cortisol responses between conditions across the day and night may relate to differences in participants’ ability to interpret the alarm when sleeping versus when awake. PMID:27157688

  8. Plasma Exosomal miRNA-122-5p and miR-300-3p as Potential Markers for Transient Ischaemic Attack in Rats.

    PubMed

    Li, Dong-Bin; Liu, Jing-Li; Wang, Wei; Luo, Xiu-Mei; Zhou, Xia; Li, Jin-Pin; Cao, Xiao-Li; Long, Xiao-Hong; Chen, Jia-Gui; Qin, Chao

    2018-01-01

    Background: Differentiation of transient ischaemic attack (TIA) from ischaemic stroke within the thrombolysis time window is difficult. Although TIA may be diagnosed within this window, the latest imaging technologies are complex and costly. Serum markers, which are non-invasive, rapid and economic, are used for diagnosis and prognosis of various diseases. Exosome-derived miRNA markers for TIA are unknown. Methods: We examined focal brain ischaemia produced by occlusion of the middle cerebral artery (MCAo) for 5 min, 10 min, and 2 h in rats. Exosomal miRNAs with consistent trends in cerebrospinal fluid (CSF) and plasma were identified by deep sequencing and quantitative real-time polymerase chain reaction (qRT-PCR). The areas under the curve (AUC) of the receiver operating characteristic (ROC) curve were used to evaluate the diagnostic accuracy of these miRNAs for TIA in rats. Results: Rno-miR-122-5p and rno-miR-300-3p were selected. Plasma exosomal rno-miR-122-5p was significantly downregulated in 10 min ischaemic rats compared with control and 5 min plasma. Plasma exosomal rno-miR-300-3p was significantly upregulated in 5 min ischaemic rats compared with control, 10 min and 2 h rats. Plasma and CSF levels of these miRNAs were correlated. ROC analysis showed high AUC values for rno-miR-122-5p (0.960) and rno-miR-300-3p (0.970) in the 10 and 5 min rats, respectively, compared with controls. Conclusions: Plasma exosomal rno-miR-122-5p and rno-miR-300-3p may be blood-based TIA biomarkers.

  9. Time-dependent effect of clonidine on microvascular permeability during endotoxemia.

    PubMed

    Schmidt, Karsten; Hernekamp, Jochen Frederick; Philipsenburg, Christoph; Zivkovic, Aleksandar R; Brenner, Thorsten; Hofer, Stefan

    2015-09-01

    Endothelial leakage with accompanying tissue edema and increased leukocyte adhesion are characteristics of the vascular inflammatory response. Tissue edema formation is a key mechanism in sepsis pathophysiology contributing to impaired tissue oxygenation and the development of shock. Sepsis mortality is directly associated with the severity of these microcirculatory alterations. Dysfunction of the sympathetic nervous system can have deleterious effects in generalized inflammation. This study evaluated the effect of the adrenergic alpha 2 agonist clonidine on microvascular permeability and leukocyte adhesion during endotoxemia. Macromolecular leakage, leukocyte adhesion, and venular wall shear rate were examined in mesenteric postcapillary venules of rats by using intravital microscopy (IVM). Lipopolysaccharide (LPS) (4mg/kg/h) or equivalent volumes of saline were continuously infused following baseline IVM at 0min. IVM was repeated after 60 and 120min in endotoxemic and nonendotoxemic animals. Clonidine (10μg/kg) was applied as an i.v. bolus. Animals received either (i) saline alone, (ii) clonidine alone, (iii) clonidine 45min prior to LPS, (iv) clonidine 10min prior to LPS, (v) clonidine 30min after LPS, or (vi) LPS alone. Due to nonparametric data distribution, Wilcoxon test and Dunn's multiple comparisons test were used for data analysis. Data were considered statistically significant at p<0.05. LPS significantly increased microvascular permeability and leukocyte adhesion and decreased venular wall shear rate. Clonidine significantly reduced microvascular permeability when applied 45min before or 30min after LPS administration. Leukocyte adhesion and venular wall shear rate were not affected by clonidine during endotoxemia. Clonidine reduces microvascular permeability in endotoxemic animals in a time-dependent manner. Adrenergic alpha 2 agonists might prove beneficial in stabilizing capillary leakage during inflammation. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Single-sample method for the estimation of glomerular filtration rate in children

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tauxe, W.N.; Bagchi, A.; Tepe, P.G.

    1987-03-01

    A method for the determination of the glomerular filtration rate (GFR) in children which involves the use of a single-plasma sample (SPS) after the injection of a radioactive indicator such as radioiodine labeled diatrizoate (Hypaque) has been developed. This is analogous to previously published SPS techniques of effective renal plasma flow (ERPF) in adults and children and GFR SPS techniques in adults. As a reference standard, GFR has been calculated from compartment analysis of injected radiopharmaceuticals (Sapirstein Method). Theoretical volumes of distribution were calculated at various times after injection (Vt) by dividing the total injected counts (I) by the plasmamore » concentration (Ct) expressed in liters, determined by counting an aliquot of plasma in a well type scintillation counter. Errors of predicting GFR from the various Vt values were determined as the standard error of estimate (Sy.x) in ml/min. They were found to be relatively high early after injection and to fall to a nadir of 3.9 ml/min at 91 min. The Sy.x Vt relationship was examined in linear, quadratic, and exponential form, but the simpler linear relationship was found to yield the lowest error. Other data calculated from the compartment analysis of the reference plasma disappearance curves are presented, but at this time have apparently little clinical relevance.« less

  11. Forecasting of UV-Vis absorbance time series using artificial neural networks combined with principal component analysis.

    PubMed

    Plazas-Nossa, Leonardo; Hofer, Thomas; Gruber, Günter; Torres, Andres

    2017-02-01

    This work proposes a methodology for the forecasting of online water quality data provided by UV-Vis spectrometry. Therefore, a combination of principal component analysis (PCA) to reduce the dimensionality of a data set and artificial neural networks (ANNs) for forecasting purposes was used. The results obtained were compared with those obtained by using discrete Fourier transform (DFT). The proposed methodology was applied to four absorbance time series data sets composed by a total number of 5705 UV-Vis spectra. Absolute percentage errors obtained by applying the proposed PCA/ANN methodology vary between 10% and 13% for all four study sites. In general terms, the results obtained were hardly generalizable, as they appeared to be highly dependent on specific dynamics of the water system; however, some trends can be outlined. PCA/ANN methodology gives better results than PCA/DFT forecasting procedure by using a specific spectra range for the following conditions: (i) for Salitre wastewater treatment plant (WWTP) (first hour) and Graz West R05 (first 18 min), from the last part of UV range to all visible range; (ii) for Gibraltar pumping station (first 6 min) for all UV-Vis absorbance spectra; and (iii) for San Fernando WWTP (first 24 min) for all of UV range to middle part of visible range.

  12. Application of Raman spectroscopy for on-line monitoring of low dose blend uniformity.

    PubMed

    Hausman, Debra S; Cambron, R Thomas; Sakr, Adel

    2005-07-14

    On-line Raman spectroscopy was used to evaluate the effect of blending time on low dose, 1%, blend uniformity of azimilide dihydrochloride. An 8 qt blender was used for the experiments and instrumented with a Raman probe through the I-bar port. The blender was slowed to 6.75 rpm to better illustrate the blending process (normal speed is 25 rpm). Uniformity was reached after 20 min of blending at 6.75 rpm (135 revolutions or 5.4 min at 25 rpm). On-line Raman analysis of blend uniformity provided more benefits than traditional thief sampling and off-line analysis. On-line Raman spectroscopy enabled generating data rich blend profiles, due to the ability to collect a large number of samples during the blending process (sampling every 20s). In addition, the Raman blend profile was rapidly generated, compared to the lengthy time to complete a blend profile with thief sampling and off-line analysis. The on-line Raman blend uniformity results were also significantly correlated (p-value < 0.05) to the HPLC uniformity results of thief samples.

  13. The relationship between time spent communicating and communication outcomes on a hospital medicine service.

    PubMed

    Rothberg, Michael B; Steele, John R; Wheeler, John; Arora, Ashish; Priya, Aruna; Lindenauer, Peter K

    2012-02-01

    Quality care depends on effective communication between caregivers, but it is unknown whether time spent communicating is associated with communication outcomes. To assess the association between time spent communicating, agreement on plan of care, and patient satisfaction. Time-motion study with cross-sectional survey. Academic medical center. Physicians, patients, and nurses on a hospital medicine service. Hospitalists' forms of communication were timed with a stopwatch. Physician-nurse agreement on the plan of care and patient satisfaction with physician communication were assessed via survey. Eighteen hospitalists were observed caring for 379 patients. On average, physicians spent more time per patient on written than verbal communication (median: 9.2 min. vs. 6.3 min, p<0.001). Verbal communication was greatest with patients (mean time 5.3 min, range 0-37 min), then other physicians (1.4 min), families (1.1 min), nurses (1.1 min), and case managers (0.4 min). There was no verbal communication with nurses in 30% of cases. Nurses and physicians agreed most about planned procedures (87%), principal diagnosis (74%), tests ordered (73%), anticipated discharge date (69%) and least regarding medication changes (59%). There was no association between time spent communicating and agreement on plan of care. Among 123 patients who completed surveys (response rate 32%), time physicians spent talking to patients was not correlated with patients' satisfaction with physician communication (Pearson correlation coefficient = 0.09, p=0.30). Hospitalists vary in the amount of time they spend communicating, but we found no association between time spent and either patient satisfaction or nurse-physician agreement on plan of care.

  14. One-Step Pyrolytic Synthesis of Multiwalled Carbon Nanotubes: The Role of Resupply of Carbon Species on the Quality Control.

    PubMed

    Rajavel, Krishnamoorthy; Saravanan, Padmanapan; Kumar, Ramasamy Thangavelu Rajendra

    2018-05-01

    An investigation on varying experimental parameters such as solution quantity (2.5, 5 and 7.5 mL) and reaction time (15, 30, 45 and 60 min) was carried out for the production of high-quality multiwalled carbon nanotubes (MWCNTs) in one step pyrolysis. Structural analysis revealed the uniform diameter distribution and the length of nanotubes in the range of 60-80 nm and 0.4-2 μm, respectively. Raman and X-ray diffraction analysis showed a remarkable reduction in defect density with increase in graphitization degree, upon increasing the solution volume and reaction time. MWCNTs prepared at higher solution quantity (7.5 mL) with higher reaction time (60 min) showed higher crystallinity (70% graphitization) and lower defect density (ID/IG: 0.56). The attainment in equilibrium of evaporation cum precipitation in formation of high quality nanotubes structure is evaluated. An effective resupplying of condensed precursors by re-evaporation leads for the achievement of low defect density nanotubes with higher product yield is achieved.

  15. Polysaccharide based edible coating on sapota fruit

    NASA Astrophysics Data System (ADS)

    Menezes, Joslin; Athmaselvi, K. A.

    2016-10-01

    Sapota fruits are highly perishable and have short shelf life at the ambient conditions. The edible coatings have been used on different agricultural products in order to extend their post harvest life. In the present study, the polysaccharide based edible coating made up of sodium alginate and pectin (2%) was studied on the shelf life of sapota fruits. The coating of the fruits is done by dipping method with two dipping time (2 and 4 min). The both control and coated sapota fruits were stored at refrigerated temperature (4±1°C). The physico-chemical analysis including acidity, total soluble solids, ascorbic acid, pH, weight loss, colour and firmness were measured on 1, 8, 15, 23 and 30th day of storage. There was significant difference (p≤0.05) in these physico-chemical parameters between control and coated sapota fruits with 2 and 4 min dipping time. The sensory analysis of control and coated sapota fruits showed that, the polysaccharide coating with 2 minutes dipping time was effective in maintaining the organoleptic properties of the fruits.

  16. Scale-specific effects: A report on multiscale analysis of acupunctured EEG in entropy and power

    NASA Astrophysics Data System (ADS)

    Song, Zhenxi; Deng, Bin; Wei, Xile; Cai, Lihui; Yu, Haitao; Wang, Jiang; Wang, Ruofan; Chen, Yingyuan

    2018-02-01

    Investigating acupuncture effects contributes to improving clinical application and understanding neuronal dynamics under external stimulation. In this report, we recorded electroencephalography (EEG) signals evoked by acupuncture at ST36 acupoint with three stimulus frequencies of 50, 100 and 200 times per minutes, and selected non-acupuncture EEGs as the control group. Multiscale analyses were introduced to investigate the possible acupuncture effects on complexity and power in multiscale level. Using multiscale weighted-permutation entropy, we found the significant effects on increased complexity degree in EEG signals induced by acupuncture. The comparison of three stimulation manipulations showed that 100 times/min generated most obvious effects, and affected most cortical regions. By estimating average power spectral density, we found decreased power induced by acupuncture. The joint distribution of entropy and power indicated an inverse correlation, and this relationship was weakened by acupuncture effects, especially under the manipulation of 100 times/min frequency. Above findings are more evident and stable in large scales than small scales, which suggests that multiscale analysis allows evaluating significant effects in specific scale and enables to probe the inherent characteristics underlying physiological signals.

  17. Measurements of acoustic environments for urban soundscapes: choice of homogeneous periods, optimization of durations, and selection of indicators.

    PubMed

    Brocolini, Laurent; Lavandier, Catherine; Quoy, Mathias; Ribeiro, Carlos

    2013-07-01

    In order to minimize the duration of acoustic measurements and to characterize homogeneous areas from a temporal point of view, a series of six location measurements was carried out continuously during three months in Paris. Around fifty thousand samples of 5-min, 10-min, 15-min, 20-min, 30-min, and 1-h duration measurements were extracted for each location. Each sample is characterized by eleven energy indicators and ten event descriptors. In this paper, analysis of a crossroad location is detailed. Through hierarchical ascendant classification and artificial neural networks classification, it is shown that four homogeneous periods can be detected: two during the night, one during the day, and one transition corresponding either to the awakening or to the moment when the city falls asleep. 10-min measurements are necessary to discriminate these time periods at the crossroad location. At the end of the paper, a comparison with the other locations shows that minimum duration states in between 10 and 20 min. The homogeneous periods are connected to the human activities and depend on the location. Energy indicators such as LAeq, LA10, or LA90 and event indicators are necessary to characterize the different clusters.

  18. The negative effect of hyperbaric oxygen therapy at the acute phase of electrochemical esophageal burn induced by button battery ingestion.

    PubMed

    Aydin, Atakan; Aktas, Samil; Hafiz, Gunter; Kabakas, Fatih; Erer, Metin; Bilgic, Bilge

    2004-07-01

    Ingestion of button battery, if lodges in esophagus, causes mucosal destruction in esophagus and may damage surrounding tissues due to electrochemical reactions which may lead to esophagus perforation, tracheosefageal fistula and other serious problems. We designed an experimental study to test the effect of hyperbaric oxygen therapy on battery induced electrochemical tissue damage in the esophagus of a rabbit model and possible change with duration of contact time. Button batteries were inserted in esophagus of 40 rabbits which were divided into four groups. Groups 1 and 2 had 15 min of duration of contact time of battery in esophagus, while Groups 3 and 4 had 30 min. Groups 1 and 3 had hyperbaric oxygen therapy for 3 days; Groups 2 and 4 did not. At the end of 3rd day all animals were sacrified and samples were taken from the esophagus for determination of malondialdehyde levels and for histopathological examination to compare: mucosal destruction, muscular layer involvement, perforation and tracheal involvement between groups. Malondialdehyde levels, mucosal destruction, muscular layer involvement, perforation and tracheal involvement were significantly higher in groups which had 30 min of contact time compared to groups which had 15 min. The same assessments were significantly higher in Group 1 (15 min of contact time with hyperbaric oxygen therapy) compared to Group 2 (15 min of contact time without hyperbaric oxygen therapy). However, the difference between Group 3 (30 min of contact time with hyperbaric oxygen therapy) and Group 4 (30 min of contact time, no hyperbaric oxygen therapy) was not significant. Our study demonstrated that if contact time is 15 min HBO had an additive adverse effect to electrochemically burned esophagus by increasing free radicals and eventually tissue damage. However, if the contact time is 30 min its adverse effect is shielded by huge electrochemical destruction due to long contact time.

  19. Patient and Organizational Factors Associated With Delays in Antimicrobial Therapy for Septic Shock.

    PubMed

    Amaral, Andre C K B; Fowler, Robert A; Pinto, Ruxandra; Rubenfeld, Gordon D; Ellis, Paul; Bookatz, Brian; Marshall, John C; Martinka, Greg; Keenan, Sean; Laporta, Denny; Roberts, Daniel; Kumar, Anand

    2016-12-01

    To identify clinical and organizational factors associated with delays in antimicrobial therapy for septic shock. In a retrospective cohort of critically ill patients with septic shock. Twenty-four ICUs. A total of 6,720 patients with septic shock. None. Higher Acute Physiology Score (+24 min per 5 Acute Physiology Score points; p < 0.0001); older age (+16 min per 10 yr; p < 0.0001); presence of comorbidities (+35 min; p < 0.0001); hospital length of stay before hypotension: less than 3 days (+50 min; p < 0.0001), between 3 and 7 days (+121 min; p < 0.0001), and longer than 7 days (+130 min; p < 0.0001); and a diagnosis of pneumonia (+45 min; p < 0.01) were associated with longer times to antimicrobial therapy. Two variables were associated with shorter times to antimicrobial therapy: community-acquired infections (-53 min; p < 0.001) and higher temperature (-15 min per 1°C; p < 0.0001). After adjusting for confounders, admissions to academic hospitals (+52 min; p< 0.05), and transfers from medical wards (medical vs surgical ward admission; +39 min; p < 0.05) had longer times to antimicrobial therapy. Admissions from the emergency department (emergency department vs surgical ward admission, -47 min; p< 0.001) had shorter times to antimicrobial therapy. We identified clinical and organizational factors that can serve as evidence-based targets for future quality-improvement initiatives on antimicrobial timing. The observation that academic hospitals are more likely to delay antimicrobials should be further explored in future trials.

  20. Allergic reactions to milk appear sooner than reactions to hen's eggs: a retrospective study.

    PubMed

    Yanagida, Noriyuki; Minoura, Takanori; Kitaoka, Setsuko

    2016-01-01

    Oral food challenge test doses are recommended to be performed at least 20 min apart; however, the times of symptom provocation from the start of the oral food challenge have never been compared between different foods. In this study, the durations from the start of the oral food challenge to symptom development in children with egg or milk allergy were compared. Thirty-eight and 74 children who had previously passed oral food challenges to 96 g of yogurt and pumpkin cake containing ¼ whole egg underwent oral food challenges with 200 mL raw cow's milk and 1 whole scrambled egg, respectively; of these, 15/38 and 33/74 children had a reaction. The median ages of patients with a positive challenge were 5.8 and 5.1 years for milk and eggs, respectively. The median times for the first symptom occurrence were 20 min (range, 5-55 min) and 50 min (5-480 min), respectively (p = 0.009). The first symptoms developed within 30, 60, and 90 min in 12/15 (80 %), 15/15 (100 %), and 15/15 (100 %) children with milk allergies, and in 10/33 (30.3 %), 20/33 (60.6 %), and 26/33 (78.8 %) children with egg allergies, respectively. The median times of peak symptoms were 50 min (10-210 min) and 120 min (30-560 min) (p = 0.001), and those of symptom disappearance were 90 min (30-240 min) and 180 min (80-700 min) for milk and eggs (p = 0.002), respectively. Based on the results of our study, symptoms developed within 30 min for only a subset of patients for eggs, and may even take upwards of 60 min to develop. The times of symptom disappearance were 90 min and 180 min for milk and eggs, respectively, indicating that egg-allergic patients should be observed for a longer period time than milk-allergic patients. Allergic reactions induced by milk appeared and disappeared sooner than those induced by eggs.

  1. A comparison of plasma levobupivacaine concentrations following transversus abdominis plane block and rectus sheath block.

    PubMed

    Yasumura, R; Kobayashi, Y; Ochiai, R

    2016-05-01

    Levobupivacaine is commonly used as the local anaesthetic of choice in peripheral nerve blocks, but its pharmacokinetics have not been fully investigated. We compared the changes in plasma concentrations of levobupivacaine following transversus abdominis plane block and rectus sheath block. Fifty woman undergoing laparoscopy were randomly allocated to receive either a transversus abdominis plane block or an rectus sheath block. In both groups, 2.5 mg.kg(-1) levobupivacaine was administered, and blood samples were obtained 15 min, 30 min, 60 min and 120 min after injection. The mean maximum plasma concentration (Cmax) and mean time to reach Cmax (Tmax) as determined by non-linear regression analysis were 1.05 μg.ml(-1) and 32.4 min in the transversus abdominis plane group and 0.95 μg.ml(-1) and 60.9 min in the rectus sheath group, respectively. The plasma concentration of levobupivacaine peaked earlier in the transversus abdominis plane group than in the rectus sheath group and the maximum plasma concentration depended on the dose administered but not the procedure. © 2016 The Association of Anaesthetists of Great Britain and Ireland.

  2. A study on quantitative analysis of exposure dose caused by patient depending on time and distance in nuclear medicine examination

    NASA Astrophysics Data System (ADS)

    Kim, H. S.; Cho, J. H.; Shin, S. G.; Dong, K. R.; Chung, W. K.; Chung, J. E.

    2013-01-01

    This study evaluated possible actions that can help protect against and reduce radiation exposure by measuring the exposure dose for each type of isotope that is used frequently in nuclear medicine before performing numerical analysis of the effective half-life based on the measurement results. From July to August in 2010, the study targeted 10, 6 and 5 people who underwent an 18F-FDG (fludeoxyglucose) positron emission tomography (PET) scan, 99mTc-HDP bone scan, and 201Tl myocardial single-photon emission computed tomography (SPECT) scan, respectively, in the nuclear medicine department. After injecting the required medicine into the subjects, a survey meter was used to measure the dose depending on the distance from the heart and time elapsed. For the 18F-FDG PET scan, the dose decreased by approximately 66% at 90 min compared to that immediately after the injection and by 78% at a distance of 1 m compared to that at 0.3 m. In the 99mTc-HDP bone scan, the dose decreased by approximately 71% in 200 min compared to that immediately after the injection and by approximately 78% at a distance of 1 m compared to that at 0.3 m. In the 201Tl myocardial SPECT scan, the dose decreased by approximately 30% in 250 min compared to that immediately after the injection and by approximately 55% at a distance of 1 m compared to that at 0.3 m. In conclusion, the dose decreases by a large margin depending on the distance and time. In conclusion, this study measured the exposure doses by isotopes, distance from the heart and exposure time, and found that the doses were reduced significantly according the distance and the time.

  3. Micro vs. macrodiscectomy: Does use of the microscope reduce complication rates?

    PubMed

    Murphy, Meghan E; Hakim, Jeffrey S; Kerezoudis, Panagiotis; Alvi, Mohammed Ali; Ubl, Daniel S; Habermann, Elizabeth B; Bydon, Mohamad

    2017-01-01

    A single level discectomy is one of the most common procedures performed by spine surgeons. While some practitioners utilize the microscope, others do not. We postulate improved visualization with an intraoperative microscope decreases complications and inferior outcomes. A multicenter surgical registry was utilized for this retrospective cohort analysis. Patients with degenerative spinal diagnoses undergoing elective single level discectomies from 2010 to 2014 were included. Univariate analysis was performed comparing demographics, patient characteristics, operative data, and outcomes for discectomies performed with and without a microscope. Multivariable logistic regression analysis was then applied to compare outcomes of micro- and macrodiscectomies. Query of the registry yielded 23,583 patients meeting inclusion criteria. On univariate analysis the microscope was used in a greater proportion of the oldest age group as well as Hispanic white patients. Patients with any functional dependency, history of congestive heart failure, chronic corticosteroid use, or anemia (hematocrit<35%) also had greater proportions of microdiscectomies. Thoracic region discectomies more frequently involved use of the microscope than cervical or lumbar discectomies (25.0% vs. 16.4% and 13.0%, respectively, p<0.001). Median operative time (IQR) was increased in microscope cases [80min (60, 108) vs. 74min (54, 102), p<0.001]. Of the patients that required reoperation within 30days, 2.5% of them had undergone a microdiscectomy compared to 1.9% who had undergone a macrodiscectomy, p=0.044. On multivariable analysis, microdiscectomies were more likely to have an operative time in the top quartile of discectomy operative times, ≥103min (OR 1.256, 95% CI 1.151-1.371, p<0.001). In regards to other multivariable outcome models for any complication, surgical site infection, dural tears, reoperation, and readmission, no significant association with microdiscectomy was found. The use of the microscope was found to significantly increase the odds of longer operative time, but not influence rates of postoperative complications. Thus, without evidence from this study that the microscope decreases complications, the use of the microscope should be at the surgeon's discretion, validating the use of both macro and micro approaches to discectomy as acceptable standards of care. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. The 2008 Super Tuesday Tornado Outbreak: Synthetic Dual Doppler Analysis of Contrasting Tornadic Storm Types

    NASA Technical Reports Server (NTRS)

    Knupp, Kevin R.; Coleman, Timothy; Carey, Larry; Peterson, Walt; Elkins, Calvin

    2008-01-01

    During the Super Tuesday Tornado Outbreak on 5-6 February, a significant number of storms passed within about 40 km of WSR-88D radars. This distance, combined with the significant motion vector (from the southwest at 20-25 m per second) of relatively steady storms, is amenable to a synthetic dual Doppler analysis during the times when the storms passed the WSR-88D locations. Nine storms will be analyzed using the SDD technique. The following table provides their general characteristics and nearest approach to the 88D radars. For this data set, storm structure ranges from isolated supercell to QLCS. Each storm will be analyzed for a 40-60 min period during passage by the WSR-88D radar to determine general storm properties. Analysis of high-resolution single Doppler data around the time of passage (plus or minus 30 min), combined with 1-2 SDD analyses, will be used to examine the kinematic structure of low-level circulations (e.g., mesocyclone, downdraft) and the relation to the parent storm. This analysis may provide insights on the fundamental differences between cyclonic circulations in supercell storms and those within QCLS's.

  5. A quick, optimized method for routine analysis of essential and trans-octadecenoic acids in edible fats and oils by GLC.

    PubMed

    Rodríguez-Alcalá, Luis Miguel; Calvo, María Visitación; Fontecha, Javier

    2013-01-01

    A gas chromatography procedure using a 30-m capillary column (VF-23ms) has been optimized for quick analysis (run time less than 20 min). The method is suitable for routine analysis of the fatty acid composition of edible fat and oil samples (milk, fish, vegetal and synthetic origin). The results were comparable with those obtained with a 100-m-long CP-Sil 88 column (run times between 60 and more than 100 min) in the analysis of geometric and positional isomers of polyunsaturated fatty acids. The achieved resolution of compounds from 4 to 26 carbon atoms with 0-6 double bonds, as omega-3 and omega-6 fatty acids, major trans-octadecenoic isomers and conjugated linoleic acid isomers, was higher than those reported in other proposed and reference methods for similar samples using short-length columns. The response factors obtained from the fatty acid composition of reference milk fat exhibited high feasibility and the inter-assay (VF23ms versus CP-Sil 88) and intra-assays based on relative standard deviation showed good accuracy, because they were lower than 10%.

  6. Data feedback reduces door-to-balloon time in patients with ST-elevation myocardial infarction undergoing primary percutaneous coronary intervention.

    PubMed

    Lin, Jeng-Feng; Hsu, Shun-Yi; Wu, Semon; Liau, Chiau-Suong; Chang, Heng-Chia; Liu, Chih-Jen; Huang, Hsuan-Li; Ho, Yao-Tsan; Weng, Shu-Li; Ko, Yu-Lin

    2011-01-01

    Current guidelines recommend a goal of door-to-balloon (D2B) time < 90 min for patients undergoing primary percutaneous coronary intervention (PCI) for ST-elevation myocardial infarction (STEMI). We aim to prospectively determine the effect of data feedback on D2B time and its seven individual components in primary PCI. From December 7, 2007, to June 2, 2009, 116 consecutive patients with STEMI who received PCI within 12 h of symptom onset were enrolled, including 56 patients before and 60 patients after the implementation of data feedback on July 28, 2008. The proportion of patients treated within 90 min increased from 26.8 to 55.0% (p = 0.002). On multivariable analyses, data feedback (OR 5.3, p = 0.003), known coronary artery disease (OR 5.6, p = 0.043), regular hours presentation (OR 3.3, p = 0.048), and arrival by transfer (OR 14.0, p = 0.003) were independent predictors of a D2B time less than 90 min. Median D2B time decreased from 112 min before data feedback to 87 min after data feedback (p < 0.001). The most significant decrease occurred in median door-to-ECG (11 vs. 3 min, p < 0.001), consult-to-cardiologist (5 vs. 3 min, p < 0.001), and puncture-to-balloon (21 vs. 17 min, p = 0.004) time. Data feedback to the emergency department and catheterization laboratory staff decreases D2B time in primary PCI. This simple approach may be the best first step to decrease D2B time in hospitals that are still striving to achieve the goal of D2B time < 90 min.

  7. Determination of red blood cell fatty acid profiles: Rapid and high-confident analysis by chemical ionization-gas chromatography-tandem mass spectrometry.

    PubMed

    Schober, Yvonne; Wahl, Hans Günther; Renz, Harald; Nockher, Wolfgang Andreas

    2017-01-01

    Cellular fatty acid (FA) profiles have been acknowledged as biomarkers in various human diseases. Nevertheless, common FA analysis by gas chromatography mass spectrometry (GC-MS) requires long analysis time. Hence, there is a need for feasible methods for high throughput analysis in clinical studies. FA was extracted from red blood cells (RBC) and derivatized to fatty acid methyl esters (FAME). A method using gas chromatography tandem mass spectrometry (GC-MS/MS) with ammonia-induced chemical ionization (CI) was developed for the analysis of FA profiles in human RBC. We compared this method with classical single GC-MS using electron impact ionization (EI). The FA profiles of 703 RBC samples were determined by GC-MS/MS. In contrast to EI ammonia-induced CI resulted in adequate amounts of molecular ions for further fragmentation of FAME. Specific fragments for confident quantification and fragmentation were determined for 45 FA. The GC-MS/MS method has a total run time of 9min compared to typical analysis times of up to 60min in conventional GC-MS. Intra and inter assay variations were <10% for all FA analyzed. Analysis of RBC FA composition revealed an age-dependent increase of the omega-3 eicosapentaenoic and docosahexaenoic acid, and a decline of the omega-6 linoleic acid with a corresponding rise of the omega-3 index. The combination of ammonia-induced CI and tandem mass spectrometry after GC separation allows for high-throughput, robust and confident analysis of FA profiles in the clinical laboratory. Copyright © 2016. Published by Elsevier B.V.

  8. Assessing Causality in the Association between Child Adiposity and Physical Activity Levels: A Mendelian Randomization Analysis

    PubMed Central

    Richmond, Rebecca C.; Davey Smith, George; Ness, Andy R.; den Hoed, Marcel; McMahon, George; Timpson, Nicholas J.

    2014-01-01

    Background Cross-sectional studies have shown that objectively measured physical activity is associated with childhood adiposity, and a strong inverse dose–response association with body mass index (BMI) has been found. However, few studies have explored the extent to which this association reflects reverse causation. We aimed to determine whether childhood adiposity causally influences levels of physical activity using genetic variants reliably associated with adiposity to estimate causal effects. Methods and Findings The Avon Longitudinal Study of Parents and Children collected data on objectively assessed activity levels of 4,296 children at age 11 y with recorded BMI and genotypic data. We used 32 established genetic correlates of BMI combined in a weighted allelic score as an instrumental variable for adiposity to estimate the causal effect of adiposity on activity. In observational analysis, a 3.3 kg/m2 (one standard deviation) higher BMI was associated with 22.3 (95% CI, 17.0, 27.6) movement counts/min less total physical activity (p = 1.6×10−16), 2.6 (2.1, 3.1) min/d less moderate-to-vigorous-intensity activity (p = 3.7×10−29), and 3.5 (1.5, 5.5) min/d more sedentary time (p = 5.0×10−4). In Mendelian randomization analyses, the same difference in BMI was associated with 32.4 (0.9, 63.9) movement counts/min less total physical activity (p = 0.04) (∼5.3% of the mean counts/minute), 2.8 (0.1, 5.5) min/d less moderate-to-vigorous-intensity activity (p = 0.04), and 13.2 (1.3, 25.2) min/d more sedentary time (p = 0.03). There was no strong evidence for a difference between variable estimates from observational estimates. Similar results were obtained using fat mass index. Low power and poor instrumentation of activity limited causal analysis of the influence of physical activity on BMI. Conclusions Our results suggest that increased adiposity causes a reduction in physical activity in children and support research into the targeting of BMI in efforts to increase childhood activity levels. Importantly, this does not exclude lower physical activity also leading to increased adiposity, i.e., bidirectional causation. Please see later in the article for the Editors' Summary PMID:24642734

  9. (18)F-alfatide II and (18)F-FDG dual-tracer dynamic PET for parametric, early prediction of tumor response to therapy.

    PubMed

    Guo, Jinxia; Guo, Ning; Lang, Lixin; Kiesewetter, Dale O; Xie, Qingguo; Li, Quanzheng; Eden, Henry S; Niu, Gang; Chen, Xiaoyuan

    2014-01-01

    A single dynamic PET acquisition using multiple tracers administered closely in time could provide valuable complementary information about a tumor's status under quasiconstant conditions. This study aimed to investigate the utility of dual-tracer dynamic PET imaging with (18)F-alfatide II ((18)F-AlF-NOTA-E[PEG4-c(RGDfk)]2) and (18)F-FDG for parametric monitoring of tumor responses to therapy. We administered doxorubicin to one group of athymic nude mice with U87MG tumors and paclitaxel protein-bound particles to another group of mice with MDA-MB-435 tumors. To monitor therapeutic responses, we performed dual-tracer dynamic imaging, in sessions that lasted 90 min, starting with injection via the tail vein catheters with (18)F-alfatide II, followed 40 min later by (18)F-FDG. To achieve signal separation of the 2 tracers, we fit a 3-compartment reversible model to the time-activity curve of (18)F-alfatide II for the 40 min before (18)F-FDG injection and then extrapolated to 90 min. The (18)F-FDG tumor time-activity curve was isolated from the 90-min dual-tracer tumor time-activity curve by subtracting the fitted (18)F-alfatide II tumor time-activity curve. With separated tumor time-activity curves, the (18)F-alfatide II binding potential (Bp = k3/k4) and volume of distribution (VD) and (18)F-FDG influx rate ((K1 × k3)/(k2 + k3)) based on the Patlak method were calculated to validate the signal recovery in a comparison with 60-min single-tracer imaging and to monitor therapeutic response. The transport and binding rate parameters K1-k3 of (18)F-alfatide II, calculated from the first 40 min of the dual-tracer dynamic scan, as well as Bp and VD correlated well with the parameters from the 60-min single-tracer scan (R(2) > 0.95). Compared with the results of single-tracer PET imaging, (18)F-FDG tumor uptake and influx were recovered well from dual-tracer imaging. On doxorubicin treatment, whereas no significant changes in static tracer uptake values of (18)F-alfatide II or (18)F-FDG were observed, both (18)F-alfatide II Bp and (18)F-FDG influx from kinetic analysis in tumors showed significant decreases. For therapy of MDA-MB-435 tumors with paclitaxel protein-bound particles, a significant decrease was observed only with (18)F-alfatide II Bp value from kinetic analysis but not (18)F-FDG influx. The parameters fitted with compartmental modeling from the dual-tracer dynamic imaging are consistent with those from single-tracer imaging, substantiating the feasibility of this methodology. Even though no significant differences in tumor size were found until 5 d after doxorubicin treatment started, at day 3 there were already substantial differences in (18)F-alfatide II Bp and (18)F-FDG influx rate. Dual-tracer imaging can measure (18)F-alfatide II Bp value and (18)F-FDG influx simultaneously to evaluate tumor angiogenesis and metabolism. Such changes are known to precede anatomic changes, and thus parametric imaging may offer the promise of early prediction of therapy response.

  10. Predictor variables for a half marathon race time in recreational male runners

    PubMed Central

    Rüst, Christoph Alexander; Knechtle, Beat; Knechtle, Patrizia; Barandun, Ursula; Lepers, Romuald; Rosemann, Thomas

    2011-01-01

    The aim of this study was to investigate predictor variables of anthropometry, training, and previous experience in order to predict a half marathon race time for future novice recreational male half marathoners. Eighty-four male finishers in the ‘Half Marathon Basel’ completed the race distance within (mean and standard deviation, SD) 103.9 (16.5) min, running at a speed of 12.7 (1.9) km/h. After multivariate analysis of the anthropometric characteristics, body mass index (r = 0.56), suprailiacal (r = 0.36) and medial calf skin fold (r = 0.53) were related to race time. For the variables of training and previous experience, speed in running of the training sessions (r = −0.54) were associated with race time. After multivariate analysis of both the significant anthropometric and training variables, body mass index (P = 0.0150) and speed in running during training (P = 0.0045) were related to race time. Race time in a half marathon might be partially predicted by the following equation (r2 = 0.44): Race time (min) = 72.91 + 3.045 * (body mass index, kg/m2) −3.884 * (speed in running during training, km/h) for recreational male runners. To conclude, variables of both anthropometry and training were related to half marathon race time in recreational male half marathoners and cannot be reduced to one single predictor variable. PMID:24198577

  11. Predictor variables for a half marathon race time in recreational male runners.

    PubMed

    Rüst, Christoph Alexander; Knechtle, Beat; Knechtle, Patrizia; Barandun, Ursula; Lepers, Romuald; Rosemann, Thomas

    2011-01-01

    The aim of this study was to investigate predictor variables of anthropometry, training, and previous experience in order to predict a half marathon race time for future novice recreational male half marathoners. Eighty-four male finishers in the 'Half Marathon Basel' completed the race distance within (mean and standard deviation, SD) 103.9 (16.5) min, running at a speed of 12.7 (1.9) km/h. After multivariate analysis of the anthropometric characteristics, body mass index (r = 0.56), suprailiacal (r = 0.36) and medial calf skin fold (r = 0.53) were related to race time. For the variables of training and previous experience, speed in running of the training sessions (r = -0.54) were associated with race time. After multivariate analysis of both the significant anthropometric and training variables, body mass index (P = 0.0150) and speed in running during training (P = 0.0045) were related to race time. Race time in a half marathon might be partially predicted by the following equation (r(2) = 0.44): Race time (min) = 72.91 + 3.045 * (body mass index, kg/m(2)) -3.884 * (speed in running during training, km/h) for recreational male runners. To conclude, variables of both anthropometry and training were related to half marathon race time in recreational male half marathoners and cannot be reduced to one single predictor variable.

  12. Dynamic ultrasonic nebulisation extraction coupled with headspace ionic liquid-based single-drop microextraction for the analysis of the essential oil in Forsythia suspensa.

    PubMed

    Yang, Jinjuan; Wei, Hongmin; Teng, Xiane; Zhang, Hanqi; Shi, Yuhua

    2014-01-01

    Ionic liquids have attracted much attention as an extraction solvent instead of traditional organic solvent in single-drop microextraction. However, non-volatile ionic liquids are difficult to couple with gas chromatography. Thus, the following injection system for the determination of organic compounds is described. To establish an environmentally friendly, simple, and effective extraction method for preparation and analysis of the essential oil from aromatic plants. The dynamic ultrasonic nebulisation extraction was coupled with headspace ionic liquid-based single-drop microextraction(UNE-HS/IL/SDME)for the extraction of essential oils from Forsythia suspense fruits. After 13 min of extraction for 50 mg sample, the extracts in ionic liquid were evaporated rapidly in the gas chromatography injector through a thermal desorption unit (5 s). The traditional extraction method was carried out for comparative study. The optimum conditions were: 3 μL of 1-methyl-3-octylimidazolium hexafluorophosphate was selected as the extraction solvent, the sample amount was 50 mg, the flow rate of purging gas was 200 mL/min, the extraction time was 13 min, the injection volume was 2 μL, and the thermal desorption temperature and time were 240 °C and 5 s respectively. Comparing with hydrodistillation (HD), the proposed method was environment friendly and efficient. The proposed method is environmentally friendly, time saving, with high efficiency and low consumption. It would extend the application range of the HS/SDME and would be useful especially for aromatic plants analysis. Copyright © 2013 John Wiley & Sons, Ltd.

  13. DNA analysis using an integrated microchip for multiplex PCR amplification and electrophoresis for reference samples.

    PubMed

    Le Roux, Delphine; Root, Brian E; Reedy, Carmen R; Hickey, Jeffrey A; Scott, Orion N; Bienvenue, Joan M; Landers, James P; Chassagne, Luc; de Mazancourt, Philippe

    2014-08-19

    A system that automatically performs the PCR amplification and microchip electrophoretic (ME) separation for rapid forensic short tandem repeat (STR) forensic profiling in a single disposable plastic chip is demonstrated. The microchip subassays were optimized to deliver results comparable to conventional benchtop methods. The microchip process was accomplished in sub-90 min compared with >2.5 h for the conventional approach. An infrared laser with a noncontact temperature sensing system was optimized for a 45 min PCR compared with the conventional 90 min amplification time. The separation conditions were optimized using LPA-co-dihexylacrylamide block copolymers specifically designed for microchip separations to achieve accurate DNA size calling in an effective length of 7 cm in a plastic microchip. This effective separation length is less than half of other reports for integrated STR analysis and allows a compact, inexpensive microchip design. This separation quality was maintained when integrated with microchip PCR. Thirty samples were analyzed conventionally and then compared with data generated by the microfluidic chip system. The microfluidic system allele calling was 100% concordant with the conventional process. This study also investigated allelic ladder consistency over time. The PCR-ME genetic profiles were analyzed using binning palettes generated from two sets of allelic ladders run three and six months apart. Using these binning palettes, no allele calling errors were detected in the 30 samples demonstrating that a microfluidic platform can be highly consistent over long periods of time.

  14. Cold plasma inactivates Salmonella Stanley and Escherichia coli O157:H7 inoculated on golden delicious apples.

    PubMed

    Niemira, Brendan A; Sites, Joseph

    2008-07-01

    Cold plasma generated in a gliding arc was applied to outbreak strains of Escherichia coli O157:H7 and Salmonella Stanley on agar plates and inoculated onto the surfaces of Golden Delicious apples. This novel sanitizing technology inactivated both pathogens on agar plates, with higher flow rate (40 liters/min) observed to be more efficacious than were lower flow rates (20 liters/min), irrespective of treatment time (1 or 2 min). Golden Delicious apples were treated with various flow rates (10, 20, 30, or 40 liters/min) of cold plasma for various times (1, 2, or 3 min), applied to dried spot inoculations. All treatments resulted in significant (P < 0.05) reductions from the untreated control, with 40 liters/min more effective than were lower flow rates. Inactivation of Salmonella Stanley followed a time-dependent reduction for all flow rates. Reductions after 3 min ranged from 2.9 to 3.7 log CFU/ml, close to the limit of detection. For E. coli O157:H7, 40 liters/min gave similar reductions for all treatment times, 3.4 to 3.6 log CFU/ml. At lower flow rates, inactivation was related to exposure time, with 3 min resulting in reductions of 2.6 to 3 log CFU/ml. Temperature increase of the treated apples was related to exposure time for all flow rates. The maximum temperature of any plasma-treated apple was 50.8 degrees C (28 degrees C above ambient), after 20 liters/min for 3 min, indicating that antimicrobial effects were not the result of heat. These results indicate that cold plasma is a nonthermal process that can effectively reduce human pathogens inoculated onto fresh produce.

  15. Comparison of bacterial genome assembly software for MinION data and their applicability to medical microbiology.

    PubMed

    Judge, Kim; Hunt, Martin; Reuter, Sandra; Tracey, Alan; Quail, Michael A; Parkhill, Julian; Peacock, Sharon J

    2016-09-01

    Translating the Oxford Nanopore MinION sequencing technology into medical microbiology requires on-going analysis that keeps pace with technological improvements to the instrument and release of associated analysis software. Here, we use a multidrug-resistant Enterobacter kobei isolate as a model organism to compare open source software for the assembly of genome data, and relate this to the time taken to generate actionable information. Three software tools (PBcR, Canu and miniasm) were used to assemble MinION data and a fourth (SPAdes) was used to combine MinION and Illumina data to produce a hybrid assembly. All four had a similar number of contigs and were more contiguous than the assembly using Illumina data alone, with SPAdes producing a single chromosomal contig. Evaluation of the four assemblies to represent the genome structure revealed a single large inversion in the SPAdes assembly, which also incorrectly integrated a plasmid into the chromosomal contig. Almost 50 %, 80 % and 90 % of MinION pass reads were generated in the first 6, 9 and 12 h, respectively. Using data from the first 6 h alone led to a less accurate, fragmented assembly, but data from the first 9 or 12 h generated similar assemblies to that from 48 h sequencing. Assemblies were generated in 2 h using Canu, indicating that going from isolate to assembled data is possible in less than 48 h. MinION data identified that genes responsible for resistance were carried by two plasmids encoding resistance to carbapenem and to sulphonamides, rifampicin and aminoglycosides, respectively.

  16. Creep and Creep Recovery Response of Load Cells Tested According to U.S. and International Evaluation Procedures

    PubMed Central

    Bartel, Thomas W.; Yaniv, Simone L.

    1997-01-01

    The 60 min creep data from National Type Evaluation Procedure (NTEP) tests performed at the National Institute of Standards and Technology (NIST) on 65 load cells have been analyzed in order to compare their creep and creep recovery responses, and to compare the 60 min creep with creep over shorter time periods. To facilitate this comparison the data were fitted to a multiple-term exponential equation, which adequately describes the creep and creep recovery responses of load cells. The use of such a curve fit reduces the effect of the random error in the indicator readings on the calculated values of the load cell creep. Examination of the fitted curves show that the creep recovery responses, after inversion by a change in sign, are generally similar in shape to the creep response, but smaller in magnitude. The average ratio of the absolute value of the maximum creep recovery to the maximum creep is 0.86; however, no reliable correlation between creep and creep recovery can be drawn from the data. The fitted curves were also used to compare the 60 min creep of the NTEP analysis with the 30 min creep and other parameters calculated according to the Organization Internationale de Métrologie Légale (OIML) R 60 analysis. The average ratio of the 30 min creep value to the 60 min value is 0.84. The OIML class C creep tolerance is less than 0.5 of the NTEP tolerance for classes III and III L. PMID:27805151

  17. Root cause analysis of laboratory turnaround times for patients in the emergency department.

    PubMed

    Fernandes, Christopher M B; Worster, Andrew; Hill, Stephen; McCallum, Catherine; Eva, Kevin

    2004-03-01

    Laboratory investigations are essential to patient care and are conducted routinely in emergency departments (EDs). This study reports the turnaround times at an academic, tertiary care ED, using root cause analysis to identify potential areas of improvement. Our objectives were to compare the laboratory turnaround times with established benchmarks and identify root causes for delays. Turnaround and process event times for a consecutive sample of hemoglobin and potassium measurements were recorded during an 8-day study period using synchronized time stamps. A log transformation (ln [minutes + 1]) was performed to normalize the time data, which were then compared with established benchmarks using one-sample t tests. The turnaround time for hemoglobin was significantly less than the established benchmark (n = 140, t = -5.69, p < 0.001) and that of potassium was significantly greater (n = 121, t = 12.65, p < 0.001). The hemolysis rate was 5.8%, with 0.017% of samples needing recollection. Causes of delays included order-processing time, a high proportion (43%) of tests performed on patients who had been admitted but were still in the ED waiting for a bed, and excessive laboratory process times for potassium. The turnaround time for hemoglobin (18 min) met the established benchmark, but that for potassium (49 min) did not. Root causes for delay were order-processing time, excessive queue and instrument times for potassium and volume of tests for admitted patients. Further study of these identified causes of delays is required to see whether laboratory TATs can be reduced.

  18. Teen at work: the burden of a double shift on daily activities.

    PubMed

    Teixeira, Liliane Reis; Fischer, Frida Marina; Nagai, Roberta; Turte, Samantha Lemos

    2004-01-01

    The purpose of this study was to the evaluate time spent by working and nonworking adolescents on daily activities (work, home duties, school, transportation, other activities, leisure, sleep, and naps). Twenty-seven students, 8 male workers, 8 female workers, 5 male nonworkers, and 6 female nonworkers, ages 14-18 yrs participated in the study. They attended evening classes Monday-Friday (19:00-22:30h) in a public school in the city of São Paulo, Brazil. The students answered a comprehensive questionnaire on the characterization of their life, work, and health conditions. Simultaneously, they wore actigraphs (Ambulatory Monitoring, Inc.) and completed a diary of their daily activities (time spent at work, on home duties, commuting, leisure, other activities) for a minimum of 10 to a maximum of 17 consecutive days. The means of the variables were tested for differences by a two-factor (work and sex) ANOVA and Student-t test applied to pair-wise samples (weekdays and weekends). The average duration during weekdays of working time was 7 h 09 min and home duties 0 h 48 min. As for commuting time, there was a work effect [F(1,23) = 4.9; p = 0.04]; mean commuting time was 2 h 22 min for workers (males and females) and 1 h 25 min for nonworkers. There was a significant difference between workers and nonworkers [F(1,23) = 4.6; p = 0.04] regarding extra-cirricular class activities; workers spent a mean of 3 min/day on them as opposed to 1 h 14 min by nonworkers. The average daily time spent on leisure activities by workers was 6h 31 min; whereas, for nonworkers it was 7h 38min. Time spent in school amounted to 2h 47min for workers in comparison to 3h 22min by nonworkers. There was a significant work effect upon sleep [F(1,23)= 10.0; p <0.01]. The work effect upon nighttime sleep duration was significant [F(1,23)= 16.7; p <0.01]. Male workers showed a mean night sleep of 6 h 57 min and female workers 07h 15min. The average nighttime sleep duration for nonworkers was 9 h 06 min. There was a significant interactive effect between work and sex [F(1,23)= 5.6; p=0.03] for naps. Female workers showed took shortest nap on average (36 min; SD = 26 min), and female nonworkers the longest naps (1 h 45min; SD= 35min). Study and employment exert significant impact on the life and activities of high school students. Work affects sleep and nap duration plus the amount of time spent in school and other extra-curricular activities.

  19. A novel fast gas chromatography method for higher time resolution measurements of speciated monoterpenes in air

    NASA Astrophysics Data System (ADS)

    Jones, C. E.; Kato, S.; Nakashima, Y.; Kajii, Y.

    2014-05-01

    Biogenic emissions supply the largest fraction of non-methane volatile organic compounds (VOC) from the biosphere to the atmospheric boundary layer, and typically comprise a complex mixture of reactive terpenes. Due to this chemical complexity, achieving comprehensive measurements of biogenic VOC (BVOC) in air within a satisfactory time resolution is analytically challenging. To address this, we have developed a novel, fully automated Fast Gas Chromatography (Fast-GC) based technique to provide higher time resolution monitoring of monoterpenes (and selected other C9-C15 terpenes) during plant emission studies and in ambient air. To our knowledge, this is the first study to apply a Fast-GC based separation technique to achieve quantification of terpenes in ambient air. Three chromatography methods have been developed for atmospheric terpene analysis under different sampling scenarios. Each method facilitates chromatographic separation of selected BVOC within a significantly reduced analysis time compared to conventional GC methods, whilst maintaining the ability to quantify individual monoterpene structural isomers. Using this approach, the C9-C15 BVOC composition of single plant emissions may be characterised within a 14.5 min analysis time. Moreover, in-situ quantification of 12 monoterpenes in unpolluted ambient air may be achieved within an 11.7 min chromatographic separation time (increasing to 19.7 min when simultaneous quantification of multiple oxygenated C9-C10 terpenoids is required, and/or when concentrations of anthropogenic VOC are significant). These analysis times potentially allow for a twofold to fivefold increase in measurement frequency compared to conventional GC methods. Here we outline the technical details and analytical capability of this chromatographic approach, and present the first in-situ Fast-GC observations of 6 monoterpenes and the oxygenated BVOC (OBVOC) linalool in ambient air. During this field deployment within a suburban forest ~30 km west of central Tokyo, Japan, the Fast-GC limit of detection with respect to monoterpenes was 4-5 ppt, and the agreement between Fast-GC and PTR-MS derived total monoterpene mixing ratios was consistent with previous GC/PTR-MS comparisons. The measurement uncertainties associated with the Fast-GC quantification of monoterpenes are ≤ 12%, while larger uncertainties (up to ~25%) are associated with the OBVOC and sesquiterpene measurements.

  20. Post heroin dose tissue distribution of 6-monoacetylmorphine (6-MAM) with MALDI imaging.

    PubMed

    Teklezgi, Belin G; Pamreddy, Annapurna; Baijnath, Sooraj; Gopal, Nirmala D; Naicker, Tricia; Kruger, Hendrik G; Govender, Thavendran

    2017-08-01

    Heroin is an illicit opioid drug which is commonly abused and leads to dependence and addiction. Heroin is considered a pro-drug and is rapidly converted to its major active metabolite 6-monoacetylmorphine (6-MAM) which mediates euphoria and reward through the stimulation of opioid receptors in the brain. The aim of this study was to investigate the distribution and localization of 6-MAM in the healthy Sprague Dawley rat brain following intraperitoneal (i.p) administration of heroin (10 mg/kg), using matrix-assisted laser desorption/ionization mass spectrometric imaging (MALDI-MSI), in combination with quantification via liquid chromatography mass spectrometry (LC-MS/MS). These findings revealed that 6-MAM is present both in plasma and brain tissue with a T max of 5 min (2.8 µg/mL) and 15 min (1.1 µg/mL), respectively. MSI analysis of the brain showed high intensities of 6-MAM in the thalamus-hypothalamus and mesocorticolimbic system including areas of the cortex, caudate putamen, and ventral pallidum regions. This finding correlates with the distribution of opioid receptors in the brain, according to literature. In addition, we report a time-dependent distribution in the levels of 6-MAM, from 1 min with the highest intensity of the drug observed at 15 min, with sparse distribution at 45 min before decreasing at 60 min. This is the first study to use MSI as a brain imaging technique to detect a morphine's distribution over time in the brain.

  1. TH-A-9A-10: Prostate SBRT Delivery with Flattening-Filter-Free Mode: Benefit and Accuracy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, T; Yuan, L; Sheng, Y

    Purpose: Flattening-filter-free (FFF) beam mode offered on TrueBeam™ linac enables delivering IMRT at 2400 MU/min dose rate. This study investigates the benefit and delivery accuracy of using high dose rate in the context of prostate SBRT. Methods: 8 prostate SBRT patients were retrospectively studied. In 5 cases treated with 600-MU/min dose rate, continuous prostate motion data acquired during radiation-beam-on was used to analyze motion range. In addition, the initial 1/3 of prostate motion trajectories during each radiation-beam-on was separated to simulate motion range if 2400-MU/min were used. To analyze delivery accuracy in FFF mode, MLC trajectory log files from anmore » additional 3 cases treated at 2400-MU/min were acquired. These log files record MLC expected and actual positions every 20ms, and therefore can be used to reveal delivery accuracy. Results: (1) Benefit. On average treatment at 600-MU/min takes 30s per beam; whereas 2400-MU/min requires only 11s. When shortening delivery time to ~1/3, the prostate motion range was significantly smaller (p<0.001). Largest motion reduction occurred in Sup-Inf direction, from [−3.3mm, 2.1mm] to [−1.7mm, 1.7mm], followed by reduction from [−2.1mm, 2.4mm] to [−1.0mm, 2.4mm] in Ant-Pos direction. No change observed in LR direction [−0.8mm, 0.6mm]. The combined motion amplitude (vector norm) confirms that average motion and ranges are significantly smaller when beam-on was limited to the 1st 1/3 of actual delivery time. (2) Accuracy. Trajectory log file analysis showed excellent delivery accuracy with at 2400 MU/min. Most leaf deviations during beam-on were within 0.07mm (99-percentile). Maximum leaf-opening deviations during each beam-on were all under 0.1mm for all leaves. Dose-rate was maintained at 2400-MU/min during beam-on without dipping. Conclusion: Delivery prostate SBRT with 2400 MU/min is both beneficial and accurate. High dose rates significantly reduced both treatment time and intra-beam prostate motion range. Excellent delivery accuracy was confirmed with very small leaf motion deviation.« less

  2. Sweat test for cystic fibrosis: Wearable sweat sensor vs. standard laboratory test.

    PubMed

    Choi, Dong-Hoon; Thaxton, Abigail; Jeong, In Cheol; Kim, Kain; Sosnay, Patrick R; Cutting, Garry R; Searson, Peter C

    2018-03-23

    Sweat chloride testing for diagnosis of cystic fibrosis (CF) involves sweat induction, collection and handling, and measurement in an analytical lab. We have developed a wearable sensor with an integrated salt bridge for real-time measurement of sweat chloride concentration. Here, in a proof-of-concept study, we compare the performance of the sensor to current clinical practice in CF patients and healthy subjects. Sweat was induced on both forearms of 10 individuals with CF and 10 healthy subjects using pilocarpine iontophoresis. A Macroduct sweat collection device was attached to one arm and sweat was collected for 30 min and then sent for laboratory analysis. A sensor was attached to the other arm and the chloride ion concentration monitored in real time for 30 min using a Bluetooth transceiver and smart phone app. Stable sweat chloride measurements were obtained within 15 min following sweat induction using the wearable sensor. We define the detection time as the time at which the standard deviation of the real-time chloride ion concentration remained below 2 mEq/L for 5 min. The sweat volume for sensor measurements at the detection time was 13.1 ± 11.4 μL (SD), in many cases lower than the minimum sweat volume of 15 μL for conventional testing. The mean difference between sweat chloride concentrations measured by the sensor and the conventional laboratory practice was 6.2 ± 9.5 mEq/L (SD), close to the arm-to-arm variation of about 3 mEq/L. The Pearson correlation coefficient between the two measurements was 0.97 highlighting the excellent agreement between the two methods. A wearable sensor can be used to make real-time measurements of sweat chloride within 15 min following sweat induction, requiring a small sweat volume, and with excellent agreement to standard methods. Copyright © 2018 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  3. Carbon Dioxide Versus Air Insufflation for Elective Colonoscopy: A Meta-Analysis and Systematic Review of Randomized Controlled Trials.

    PubMed

    Memon, Muhammed A; Memon, Breda; Yunus, Rossita M; Khan, Shahjahan

    2016-04-01

    The aim of this study was to conduct a meta-analysis and systematic review of randomized controlled trials (RCTs) comparing 2 methods of colonic insufflation for elective colonoscopy, that is, carbon dioxide (CO2) or air, and to evaluate their efficiency, safety, and side effects. Prospective RCTs comparing CO2 versus air insufflation for colonic distension during colonoscopy were selected by searching PubMed, Medline, Embase, Science Citation Index, Current Contents, and the Cochrane Central Register of Controlled Trials published between January 1980 and October 2014. The outcome variables analyzed included procedural and immediate postprocedural pain (during, end, or within 15 min after procedure), early postprocedural pain (between 30 and 120 min), intermediate postprocedural pain (360 min) and late postprocedural pain (720 to 1140 min), cecal/ileal intubation rate, cecal/ileal intubation time, and total colonoscopy examination time. These outcomes were unanimously decided to be important as they influence the practical approach toward patient management within and outside of hospital. Random effects model was used to calculate the effect size of both binary and continuous data. Heterogeneity among the outcome variables of these trials was determined by the Cochran Q statistic and I2 index. The meta-analysis was prepared in accordance with PRISMA guidelines. Twenty-four RCTs totaling 3996 patients (CO2=2017, Air=1979) were analyzed. Statistically significant differences for the pooled effect size were observed for procedural and immediate postprocedural pain [weighted mean difference (WMD)=0.49; 95% confidence interval (CI), 0.32, 0.73; P=0.0005], early postprocedural pain between 30 and 120 minutes (WMD=0.25; 95% CI, 0.12, 0.49; P<0.0001), intermediate postprocedural pain, that is, 360 minutes after completion (WMD=0.35; 95% CI, 0.23, 0.52; P<0.0001), and late postprocedural pain between 720 and 1440 minutes (WMD=0.53; 95% CI, 0.34, 0.84; P=0.0061). Comparable effects were noted for cecal/ileal intubation rate (WMD=0.86; 95% CI, 0.61, 1.22; P=0.3975), cecal/ileal intubation time (WMD=-0.64; 95% CI, -1.38, 0.09; P=0.0860), and total examination time (WMD=-0.20; 95% CI, -0.96, 0.57; P=0.6133). On the basis of our meta-analysis and systematic review, we conclude that CO2 insufflation significantly reduces abdominal pain during and following the procedure lasting up to 24 hours. There is no difference in the cecal/ileal intubation rate and time and total examination time between the 2 methods. CO2 retention with CO2 insufflation during and after the colonoscopy shows inconsequential variation compared with air insufflation and has no adverse effect on patients. CO2 instead of air should be routinely utilized for colonoscopy.

  4. Synthesis and application of Pb-MCM-41/ZnNiO2 as a novel mesoporous nanocomposite adsorbent for the decontamination of chloroethyl phenyl sulfide (CEPS)

    NASA Astrophysics Data System (ADS)

    Sadeghi, Meysam; Yekta, Sina; Ghaedi, Hamed

    2017-04-01

    In the current research, MCM-41 was successfully prepared by the sol-gel method and lead ions (Pb2+) were loaded in the synthesized MCM-41 mesoporous structure to prepare Pb-MCM-41. The ZnO-NiO nanoparticles (ZnNiO2 NPs) as a type of bimetallic oxides were then dispersed and deposited on the surface of Pb-MCM-41 through indirect method to gain the final Pb-MCM-41/ZnNiO2 nanocomposite adsorbent. The characterization study of samples carried out by SEM-EDAX, AFM, XRD and FTIR techniques. Pb-MCM-41/ZnNiO2 nanocomposite as a destructive adsorbent has been proposed for the first time for the decontamination process of chloroethyl phenyl sulfide (CEPS), a mimic of bis(chloroethyl) sulfide (i.e. sulfur mustard), and were confirmed using GC-FID, GC-MS and FTIR instruments. Besides, the effect of different experimental parameters including contact time, catalyst dose and initial concentration of CEPS on the decontamination efficiency of this agent simulant were also perused. The GC-FID analysis results verified that the maximum decontamination of CEPS was more than 90% yield. The parameters such as: contact time (240 min), adsorbent dose (0.4 g/L), and initial concentration (10 mg/L) were investigated and considered as optimized conditions for the noted reaction. Moreover, the reaction kinetic information was surveyed by employing first order model. The values of the rate constant (k) and half-life (t1/2) were determined as 0.0128 min-1 and 54.1406 min, and 0.0012 min-1 and 577.5 min for CEPS and its hydrolysis/elimination products, respectively. Data demonstrates the role of the hydrolysis and elimination products, i.e. hydroxy ethyl phenyl sulfide (HEPS) and phenyl vinyl sulfide (PVS) in the reaction of CEPS with Pb-MCM-41/ZnNiO2 nanocomposite and GC-MS analysis was exerted to identify and quantify simulant destruction products. It was clarified that Pb-MCM-41/ZnNiO2 nanocomposite gains a high capacity and potential for the effective decontamination of CEPS.

  5. Accessibility of general practitioners and selected specialist physicians by car and by public transport in a rural region of Germany.

    PubMed

    Stentzel, Ulrike; Piegsa, Jens; Fredrich, Daniel; Hoffmann, Wolfgang; van den Berg, Neeltje

    2016-10-19

    The accessibility of medical care facilities in sparsely populated rural regions is relevant especially for elderly people which often represent a large segment of the population in such regions. Elderly people have higher morbidity risks and a higher demand for medical care. Although travelling with private cars is the dominating traffic mode in rural regions, accessibility by public transport is increasingly important especially because of limited mobility of elderly people. The aim of this study was to determine accessibility both by car and public transport to general practitioners (GP) and selected specialist physicians for a whole region and to detect areas with poor to no access in the county Vorpommern-Greifswald, which is a rural and sparsely populated region in the very northeast of Germany. Accessibility of medical care facilities by car was calculated on the basis of a network analysis within a geographic information system (GIS) with routable street data. Accessibility by public transport was calculated using GIS and a network analysis based on the implementation of Dijkstra's algorithm. The travelling time to general practitioners (GP) by car in the study region ranges from 0.1 to 22.9 min. This is a significant difference compared to other physician groups. Traveling times to specialist physicians are 0.4 to 42.9 min. A minority of 80 % of the inhabitants reach the specialist physicians within 20 min. The accessibility of specialist physicians by public transport is poor. The travel time (round trip) to GPs averages 99.3 min, to internists 143.0, to ophthalmologists 129.3 and to urologists 159.9 min. These differences were significant. Assumed was a one hour appointment on a Tuesday at 11 am. 8,973 inhabitants (3.8 %) have no connection to a GP by public transport. 15,455 inhabitants (6.5 %) have no connection to specialist internists. Good accessibility by public transport is not a question of distance but of transport connections. GIS analyses can detect areas with imminent or manifest deficits in the accessibility of health care providers. Accessibility analyses should be established instruments in planning issues.

  6. Refining paracervical block techniques for pain control in first trimester surgical abortion: a randomized controlled noninferiority trial.

    PubMed

    Renner, Regina-Maria; Edelman, Alison B; Nichols, Mark D; Jensen, Jeffrey T; Lim, Jeong Y; Bednarek, Paula H

    2016-11-01

    Our objective was to evaluate two different aspects of the paracervical block (PCB) technique for first trimester surgical abortion, to compare a 3-min wait prior to cervical dilation to no wait and to compare four-site with two-site injection. We conducted two consecutive randomized, single-blinded noninferiority trials. In the first trial, women <11 weeks gestational age received a 20-mL 1% buffered lidocaine four-site PCB with either a 3-min wait between PCB injection and dilation or no wait. In the second trial, we compared a four-site with a two-site PCB. We evaluated dilation pain [100-mm visual analogue scale (VAS)] as the primary outcome. Secondary outcomes included pain at additional time points, anxiety, satisfaction and adverse events. Both trials fully enrolled (total n=332). Results were inconclusive as to whether no wait was noninferior to waiting 3-min prior to cervical dilation for dilation pain [VAS: 63 mm (SD, 24 mm) vs. 56 mm (SD, 32mm)] and as to whether a two-site PCB was noninferior to a four-site block [VAS: 68 mm (SD, 21 mm) vs. 60 mm (SD, 30 mm)]. Noninferiority analysis was inconclusive because the confidence interval of the mean pain score difference between groups included the predefined inferiority margin of 13-mm pain difference. Superiority analysis showed the four-site PCB to be superior to the two-site PCB. It remained inconclusive whether a 3-min wait time between PCB and cervical dilation provides noninferior pain control for first trimester surgical abortion. However, a four-site PCB appeared to be superior to a two-site PCB. It remained inconclusive whether a 3-min wait time between PCB and cervical dilation or using a two-site instead of a four-site PCB provided noninferior pain control for first trimester surgical abortion. This study did not assess whether the combination of the two separate factors provides additive benefit. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Functional integration of PCR amplification and capillary eletrophoresis in a microfabricated DNA analysis device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woolley, A.T.; deMello, A.J.; Mathies, R.A.

    Microfabricated silicon PCR reactors and glass capillary electrophoresis (CE) chips have been successfully coupled to form an integrated DNA analysis system. This construct combines the rapid thermal cycling capabilities of microfabricated PCR devices (10{degree}C/s heating, 2.5{degree}C/s cooling) with the high-speed (<120 s) DNA separations provided by microfabricated CE chips. The PCR chamber and the CE chip were directly linked through a photolithographically fabricated channel filled with hydroxyethylcellulose sieving matrix. Electrophoretic injection directly from the PCR chamber through the cross injection channel was used as an `electrophoretic valve` to couple the PCR and CE devices on-chip. To demonstrate the functionality ofmore » this system, a 15 min PCR amplification of a {Beta}-globin target cloned in m13 was immediately followed by high-speed CE chip separation in under 120 s, providing a rapid PCR-CE analysis in under 20 min. A rapid assay for genomic Salmonella DNA was performed in under 45 min, demonstrating that challenging amplifications of diagnostically interesting targets can also be performed. Real-time monitoring of PCR target amplification in these integrated PCR-CE devices is also feasible. 33 refs., 6 figs.« less

  8. S-Adenosylhomocysteine Assay in the Urine by Capillary Electrophoresis.

    PubMed

    Luzyanin, B P; Ivanov, A V; Viryus, E D; Kubatiev, A A

    2015-08-01

    We present a simple and effective method for measuring urine S-adenosylhomocysteine by capillary electrophoresis without using modifiers. The detection threshold of the method is 0.1 μM S-adenosylhomocysteine, the time of analysis 13 min, reproducibility at physiological concentrations within 4%.

  9. The effects of recovery duration during high-intensity interval exercise on time spent at high rates of oxygen consumption, oxygen kinetics and blood lactate.

    PubMed

    Smilios, Ilias; Myrkos, Aristides; Zafeiridis, Andreas; Toubekis, Argyris; Spassis, Apostolos; Tokmakidis, Savas P

    2017-03-13

    The recovery duration and the work to recovery ratio are important aspects to consider when designing a high-intensity aerobic interval exercise (HIIE). This study examined the effects of recovery duration on total exercise time performed above 80, 90 and 95% of maximum oxygen consumption (VO2max) and heart rate (HRmax) during a single-bout HIIE. We also evaluated the effects on VO2 and HR kinetics, blood lactate concentration and rating of perceived exertion (RPE). Eleven moderately trained males (22.1±1 yrs.) executed, on three separate sessions, 4×4-min runs at 90% of maximal aerobic velocity (MAV) with 2-min, 3-min and 4-min of active recovery. Recovery duration did not affect the percentage of VO2max attained and the total exercise time above 80, 90 and 95% of VO2max. Exercise time above 80 and 90% of HRmax was longer with 2 and 3 min (p<0.05) as compared with the 4-min recovery. Oxygen uptake and HR amplitude were lower, mean response time slower (p<0.05), and blood lactate and RPE higher with 2-min compared to 4-min recovery (p<0.05). In conclusion, aerobic metabolism attains its upper functional limits with either 2, or 3 or 4 min of recovery during the 4×4 min HIIE; thus, all rest durations could be used for the enhancement of aerobic capacity in sports, fitness, and clinical settings. The short (2 min) compared to longer (4 min) recovery, however, evokes greater cardiovascular and metabolic stress, and activates to a greater extent anaerobic glycolysis, and hence, could be used by athletes to induce greater overall physiological challenge.

  10. Optimization of homonuclear 2D NMR for fast quantitative analysis: application to tropine-nortropine mixtures.

    PubMed

    Giraudeau, Patrick; Guignard, Nadia; Hillion, Emilie; Baguet, Evelyne; Akoka, Serge

    2007-03-12

    Quantitative analysis by (1)H NMR is often hampered by heavily overlapping signals that may occur for complex mixtures, especially those containing similar compounds. Bidimensional homonuclear NMR spectroscopy can overcome this difficulty. A thorough review of acquisition and post-processing parameters was carried out to obtain accurate and precise, quantitative 2D J-resolved and DQF-COSY spectra in a much reduced time, thus limiting the spectrometer instabilities in the course of time. The number of t(1) increments was reduced as much as possible, and standard deviation was improved by optimization of spectral width, number of transients, phase cycling and apodization function. Localized polynomial baseline corrections were applied to the relevant chemical shift areas. Our method was applied to tropine-nortropine mixtures. Quantitative J-resolved spectra were obtained in less than 3 min and quantitative DQF-COSY spectra in 12 min, with an accuracy of 3% for J-spectroscopy and 2% for DQF-COSY, and a standard deviation smaller than 1%.

  11. Rapid analysis of 3,4-methylenedioxymethamphetamine: a comparison of nonaqueous capillary electrophoresis/fluorescence detection with GC/MS.

    PubMed

    Fang, Ching; Chung, Yu-Lin; Liu, Ju-Tsung; Lin, Cheng-Huang

    2002-02-18

    Because of the increasing use of 3,4-methylenedioxymethamphetamine (3,4-MDMA), a rapid and sensitive analytical technique is required for its detection and determination. Using nonaqueous capillary electrophoresis/fluorescence spectroscopy (NACE/FS) detection, it is possible to determine this drug at the level 0.5 ppm without any pre-treatment in less than 5 min. After liquid-liquid extraction, the sample can be condensed and a detection limit of 3,4-MDMA in urine of 50 ppb (S/N = 3) can be achieved. The precision of the method was evaluated by measuring the repeatability and intermediate precision of migration time and the corrected peak height by comparison with a 3,4-MDMA-D5 internal standard. With the conventional GC/MS method, it is necessary to derivatize the 3,4-MDMA before injection and the GC migration time also is in excess of 20 min. Therefore, NACE/FS represents a good complementary method to GC/MS for use in forensic analysis.

  12. Effective Thermal Inactivation of the Spores of Bacillus cereus Biofilms Using Microwave.

    PubMed

    Park, Hyong Seok; Yang, Jungwoo; Choi, Hee Jung; Kim, Kyoung Heon

    2017-07-28

    Microwave sterilization was performed to inactivate the spores of biofilms of Bacillus cereus involved in foodborne illness. The sterilization conditions, such as the amount of water and the operating temperature and treatment time, were optimized using statistical analysis based on 15 runs of experimental results designed by the Box-Behnken method. Statistical analysis showed that the optimal conditions for the inactivation of B. cereus biofilms were 14 ml of water, 108°C of temperature, and 15 min of treatment time. Interestingly, response surface plots showed that the amount of water is the most important factor for microwave sterilization under the present conditions. Complete inactivation by microwaves was achieved in 5 min, and the inactivation efficiency by microwave was obviously higher than that by conventional steam autoclave. Finally, confocal laser scanning microscopy images showed that the principal effect of microwave treatment was cell membrane disruption. Thus, this study can contribute to the development of a process to control food-associated pathogens.

  13. Influence evaluation of loading conditions during pressurized thermal shock transients based on thermal-hydraulics and structural analyses

    NASA Astrophysics Data System (ADS)

    Katsuyama, Jinya; Uno, Shumpei; Watanabe, Tadashi; Li, Yinsheng

    2018-03-01

    The thermal hydraulic (TH) behavior of coolant water is a key factor in the structural integrity assessments on reactor pressure vessels (RPVs) of pressurized water reactors (PWRs) under pressurized thermal shock (PTS) events, because the TH behavior may affect the loading conditions in the assessment. From the viewpoint of TH behavior, configuration of plant equipment and their dimensions, and operator action time considerably influence various parameters, such as the temperature and flow rate of coolant water and inner pressure. In this study, to investigate the influence of the operator action time on TH behavior during a PTS event, we developed an analysis model for a typical Japanese PWR plant, including the RPV and the main components of both primary and secondary systems, and performed TH analyses by using a system analysis code called RELAP5. We applied two different operator action times based on the Japanese and the United States (US) rules: Operators may act after 10 min (Japanese rules) and 30 min (the US rules) after the occurrence of PTS events. Based on the results of TH analysis with different operator action times, we also performed structural analyses for evaluating thermal-stress distributions in the RPV during PTS events as loading conditions in the structural integrity assessment. From the analysis results, it was clarified that differences in operator action times significantly affect TH behavior and loading conditions, as the Japanese rule may lead to lower stresses than that under the US rule because an earlier operator action caused lower pressure in the RPV.

  14. Determination of dasatinib in the tablet dosage form by ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis.

    PubMed

    Gonzalez, Aroa Garcia; Taraba, Lukáš; Hraníček, Jakub; Kozlík, Petr; Coufal, Pavel

    2017-01-01

    Dasatinib is a novel oral prescription drug proposed for treating adult patients with chronic myeloid leukemia. Three analytical methods, namely ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis, were developed, validated, and compared for determination of the drug in the tablet dosage form. The total analysis time of optimized ultra high performance liquid chromatography and capillary zone electrophoresis methods was 2.0 and 2.2 min, respectively. Direct ultraviolet detection with detection wavelength of 322 nm was employed in both cases. The optimized sequential injection analysis method was based on spectrophotometric detection of dasatinib after a simple colorimetric reaction with folin ciocalteau reagent forming a blue-colored complex with an absorbance maximum at 745 nm. The total analysis time was 2.5 min. The ultra high performance liquid chromatography method provided the lowest detection and quantitation limits and the most precise and accurate results. All three newly developed methods were demonstrated to be specific, linear, sensitive, precise, and accurate, providing results satisfactorily meeting the requirements of the pharmaceutical industry, and can be employed for the routine determination of the active pharmaceutical ingredient in the tablet dosage form. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Sleeping Pill Administration Time and Patient Subjective Satisfaction

    PubMed Central

    Chung, Seockhoon; Youn, Soyoung; Yi, Kikyoung; Park, Boram; Lee, Suyeon

    2016-01-01

    Study Objectives: Taking hypnotic agents 30 min before bedtime is the usual suggested administration time, but some patients report dissatisfaction with their sleeping pills. We investigated whether the timing of sleeping pill administration influences patient subjective satisfaction with these drugs. Methods: One hundred twelve patients with primary insomnia currently taking benzodiazepine or nonbenzodiazepine gamma-aminobutyric acid (GABA) agonists as sleeping pills were selected. The time of administration for their sleeping pills, bedtime, sleep onset time, and wake up time were obtained from their medical records. Subjects were also categorized into satisfied or dissatisfied groups. Results: Hypnotic agents administration time (p < 0.001) and bedtime (p < 0.001), but not sleep onset or wake up time, occurred later in the night in the satisfied group. The durations from administration of pills to sleep onset (33.6 ± 20.7 min) and to wake up time (7.2 ± 1.2 h) were significantly shorter in the satisfied group when compared to the dissatisfied group (135.9 ± 73.4 min and 9.3 ± 1.5 h for time to sleep onset and wake up, respectively). Logistic regression analysis revealed that patient subjective satisfaction with hypnotic agents could be predicted by a short duration from administration of pills to sleep onset (odds ratio = 0.01; 95% confidence interval [0.001–0.09]) and a short duration from administration of pills to wake up time (0.53; [0.31–0.89], F = 49.9, p < 0.001). Conclusions: Taking sleeping pills at a later time and a shorter interval between pill administration and wake up time may increase patient subjective satisfaction with hypnotic agents. We propose that physicians advise patients to take sleeping pills approximately 7 h before their usual getting-out-of-bed time instead of the current standard of 30 min before bedtime. Citation: Chung S, Youn S, Yi K, Park B, Lee S. Sleeping pill administration time and patient subjective satisfaction. J Clin Sleep Med 2016;12(1):57–62. PMID:26285113

  16. Comparison of drug administration logistics between prothrombin complex concentrates and plasma in the emergency department.

    PubMed

    Alarfaj, Sumaiah J; Jarrell, Daniel H; Patanwala, Asad E

    2018-03-24

    Prothrombin complex concentrate (PCC) is used as an alternative to fresh frozen plasma (FFP) for emergency bleeding. The primary objective of this study was to compare the time from order to start of administration between 3-factor PCC (PCC3), 4-factor (PCC4), and FFP in the emergency department (ED). The secondary objective was to evaluate the effect of an ED pharmacist on time to administration of PCCs. This was a single center three-arm retrospective cohort study. Adult patients in the ED with bleeding were included. The primary outcome measure was the time from order to administration, which was compared between PCC3, PCC4, and FFP. The time from order to administration was also compared when the ED pharmacist was involved versus not involved in the care of patients receiving PCC. There were 90 patients included in the study cohort (30 in each group). The median age was 69years (IQR 57-82years), and 57% (n=52) were male. The median time from order to administration was 36min (IQR 20-58min) for PCC3, 34min (IQR 18-48min) for PCC4, and 92min (IQR 63-133) for FFP (PCC3 versus PCC4, p=0.429; PCC3 versus FFP, p<0.001; PCC4 versus FFP, p<0.001). The median time from order to administration was significantly decreased when the ED pharmacist was involved (24min [IQR 15-35min] versus 42min [IQR 32-59min], p<0.001). Time from order to administration is faster with PCC than FFP. ED pharmacist involvement decreases the time from order to administration of PCC. Copyright © 2018. Published by Elsevier Inc.

  17. Clevidipine for severe hypertension in patients with renal dysfunction: A VELOCITY trial analysis

    PubMed Central

    PEACOCK, W FRANK; VARON, JOSEPH; EBRAHIMI, RAMIN; DUNBAR, LALA; POLLACK, CHARLES V

    2011-01-01

    Introduction. Acute and severe hypertension is common, especially in patients with renal dysfunction (RD). Clevidipine is a rapidly acting (t½∼1 min) intravenous (IV) dihydropyridine calcium-channel blocker metabolized by blood and tissue esterases and may be useful in patients with RD. The purpose of this analysis was to assess the safety and efficacy of clevidipine in patients with RD. Methods. VELOCITY, a multicenter open-label study of severe hypertension, enrolled 126 patients with persistent systolic blood pressure (SBP) >180 mmHg. Investigators pre-specified a SBP initial target range (ITR) for each patient to be achieved within 30 min. Blood pressure monitoring was by cuff. Clevidipine was infused via peripheral IV at 2 mg/h for at least 3 min, then doubled every 3 min as needed to a maximum of 32 mg/h (non-weightbased treat-to-target protocol). Per protocol, clevidipine was continued for at least 18 h (96 h maximum). RD was diagnosed and reported as an end-organ injury by the investigator and was defined as requiring dialysis or an initial creatinine >2.0 mg/dl. Primary endpoints were the percentage of patients within the ITR by 30 min and the percentage below the ITR after 3 min of clevidipine infusion. Results. Of the 24 patients with moderate to severe RD, most (13/24) were dialysis dependent. Forty-six percent were male, with mean age 51 >14 years; 63% were black and 96% had a hypertension history. Median time to achieve the ITR was 8.5 min. Almost 90% of patients reached the ITR in 30 min without evidence of overshoot and were maintained on clevidipine through 18 h. Most patients (88%) transitioned to oral antihypertensive therapy within 6 h of clevidipine termination. Conclusions. This report is the first demonstrating that clevidipine is safe and effective in RD complicated by severe hypertension. Prolonged infusion maintained blood pressure within a target range and allowed successful transition to oral therapy. PMID:21091269

  18. Batch and Continuous Ultrasound Assisted Extraction of Boldo Leaves (Peumus boldus Mol.).

    PubMed

    Petigny, Loïc; Périno-Issartier, Sandrine; Wajsman, Joël; Chemat, Farid

    2013-03-12

    Vegetal extracts are widely used as primary ingredients for various products from creams to perfumes in the pharmaceutical, nutraceutic and cosmetic industries. Having concentrated and active extract is essential, as the process must extract as much soluble material as possible in a minimum time, using the least possible volume of solvent. The boldo leaves extract is of great interest for the industry as it holds a great anti-oxidant activity due to high levels of flavonoids and alkaloids such as boldine. Ultrasound Assisted Extraction (UAE) has been used to improve the efficiency of the plant extraction, reducing extraction time, increasing the concentration of the extract with the same amount of solvent and plant material. After a preliminary study, a response surface method has been used to optimize the extraction of soluble material from the plant. The results provided by the statistical analysis revealed that the optimized conditions were: sonication power 23 W/cm2 for 40 min and a temperature of 36 °C. The optimized parameters of the UAE provide a better extraction compared to a conventional maceration in terms of process time (30 min instead of 120 min), higher yield, more energy saving, cleanliness, safety and product quality.

  19. Batch and Continuous Ultrasound Assisted Extraction of Boldo Leaves (Peumus boldus Mol.)

    PubMed Central

    Petigny, Loïc; Périno-Issartier, Sandrine; Wajsman, Joël; Chemat, Farid

    2013-01-01

    Vegetal extracts are widely used as primary ingredients for various products from creams to perfumes in the pharmaceutical, nutraceutic and cosmetic industries. Having concentrated and active extract is essential, as the process must extract as much soluble material as possible in a minimum time, using the least possible volume of solvent. The boldo leaves extract is of great interest for the industry as it holds a great anti-oxidant activity due to high levels of flavonoids and alkaloids such as boldine. Ultrasound Assisted Extraction (UAE) has been used to improve the efficiency of the plant extraction, reducing extraction time, increasing the concentration of the extract with the same amount of solvent and plant material. After a preliminary study, a response surface method has been used to optimize the extraction of soluble material from the plant. The results provided by the statistical analysis revealed that the optimized conditions were: sonication power 23 W/cm2 for 40 min and a temperature of 36 °C. The optimized parameters of the UAE provide a better extraction compared to a conventional maceration in terms of process time (30 min instead of 120 min), higher yield, more energy saving, cleanliness, safety and product quality. PMID:23481637

  20. Statistical optimization of ultraviolet irradiate conditions for vitamin D₂ synthesis in oyster mushrooms (Pleurotus ostreatus) using response surface methodology.

    PubMed

    Wu, Wei-Jie; Ahn, Byung-Yong

    2014-01-01

    Response surface methodology (RSM) was used to determine the optimum vitamin D2 synthesis conditions in oyster mushrooms (Pleurotus ostreatus). Ultraviolet B (UV-B) was selected as the most efficient irradiation source for the preliminary experiment, in addition to the levels of three independent variables, which included ambient temperature (25-45°C), exposure time (40-120 min), and irradiation intensity (0.6-1.2 W/m2). The statistical analysis indicated that, for the range which was studied, irradiation intensity was the most critical factor that affected vitamin D2 synthesis in oyster mushrooms. Under optimal conditions (ambient temperature of 28.16°C, UV-B intensity of 1.14 W/m2, and exposure time of 94.28 min), the experimental vitamin D2 content of 239.67 µg/g (dry weight) was in very good agreement with the predicted value of 245.49 µg/g, which verified the practicability of this strategy. Compared to fresh mushrooms, the lyophilized mushroom powder can synthesize remarkably higher level of vitamin D2 (498.10 µg/g) within much shorter UV-B exposure time (10 min), and thus should receive attention from the food processing industry.

  1. Decalcifying capability of irrigating solutions on root canal dentin mineral content

    PubMed Central

    Poggio, Claudio; Dagna, Alberto; Vinci, Andrea; Beltrami, Riccardo; Cucca, Lucia; Giardino, Luciano

    2015-01-01

    Background: Chelating agents are believed to aid root canal irrigation and to be able to remove the inorganic smear layer. Aims: The purpose of the present study was to evaluate and to compare the decalcifying capability of different irrigating solutions (Tubuliclean, Largal Ultra, ethylenediaminetetraacetic acid 17%, Tetraclean, Tetraclean NA). Materials and Methods: Sixty maxillary central incisors were used. Root canals were instrumented and irrigated. From each root, four comparable slices of cervical dentin were obtained. At three successive 5-min interval immersion times, the concentration of calcium extracted from root canal dentin was assessed with an inductively coupled plasma-atomic emission spectrometer. Statistical Analysis Used: Data were analyzed by means of Kruskal Wallis and Mann–Whitney tests. Significance was predetermined at P < 0.05. Results and Conclusions: For all irrigating solutions, the maximum amount of Ca2+ extracted from root canal dentin samples was reached after 10 min contact time except for citric acid-based agents (Tetraclean and Tetraclean NA) which induced a higher and still increasing calcium release even after 10 min contact time. In order to obtain an efficient decalcifying action on dentin and to facilitate the biomechanical procedures, citric acid-based irrigants can be applied. PMID:26097355

  2. Characterisation of the volatile profile of coconut water from five varieties using an optimised HS-SPME-GC analysis.

    PubMed

    Prades, Alexia; Assa, Rebecca Rachel Ablan; Dornier, Manuel; Pain, Jean-Pierre; Boulanger, Renaud

    2012-09-01

    Coconut (Cocos nucifera L.) water is a refreshing tropical drink whose international market has recently been growing. However, little is yet known about its physicochemical composition, particularly its aroma. This study set out to characterise the volatile profile of water from five coconut varieties. Aroma compounds were characterised by headspace solid phase microextraction gas chromatography (HS-SPME-GC) analysis. An experimental design was established to optimise SPME conditions, leading to an equilibration time of 10 min followed by an extraction time of 60 min at 50 °C. Accordingly, immature coconut water from WAT (West African Tall), PB121 (MYD × WAT Hybrid), MYD (Malayan Yellow Dwarf), EGD (Equatorial Guinea Green Dwarf) and THD (Thailand Aromatic Green Dwarf) palms was analysed and described. Ketones were mainly present in the Tall and Hybrid varieties, whereas aldehydes were most abundant in the Dwarf palms. Tall coconut water was characterised by a high lactone content. THD exhibited a high ethyl octanoate level. The cluster analysis of the volatile fraction from the five coconut cultivars was found to be related to their genetic classification. The volatile compounds of immature coconut water from five varieties were characterised for the first time. Volatile profile analysis could be a useful tool for the selection of Dwarf coconut varieties, which are mainly consumed as a beverage. Copyright © 2012 Society of Chemical Industry.

  3. High throughput on-chip analysis of high-energy charged particle tracks using lensfree imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luo, Wei; Shabbir, Faizan; Gong, Chao

    2015-04-13

    We demonstrate a high-throughput charged particle analysis platform, which is based on lensfree on-chip microscopy for rapid ion track analysis using allyl diglycol carbonate, i.e., CR-39 plastic polymer as the sensing medium. By adopting a wide-area opto-electronic image sensor together with a source-shifting based pixel super-resolution technique, a large CR-39 sample volume (i.e., 4 cm × 4 cm × 0.1 cm) can be imaged in less than 1 min using a compact lensfree on-chip microscope, which detects partially coherent in-line holograms of the ion tracks recorded within the CR-39 detector. After the image capture, using highly parallelized reconstruction and ion track analysis algorithms running on graphics processingmore » units, we reconstruct and analyze the entire volume of a CR-39 detector within ∼1.5 min. This significant reduction in the entire imaging and ion track analysis time not only increases our throughput but also allows us to perform time-resolved analysis of the etching process to monitor and optimize the growth of ion tracks during etching. This computational lensfree imaging platform can provide a much higher throughput and more cost-effective alternative to traditional lens-based scanning optical microscopes for ion track analysis using CR-39 and other passive high energy particle detectors.« less

  4. Reallocating sedentary time to moderate-to-vigorous physical activity but not to light-intensity physical activity is effective to reduce adiposity among youths: a systematic review and meta-analysis.

    PubMed

    García-Hermoso, A; Saavedra, J M; Ramírez-Vélez, R; Ekelund, U; Del Pozo-Cruz, B

    2017-09-01

    The aim of the study was to summarize the evidence of the effects of reallocating time spent in sedentary behaviours in different activity intensities on youth's adiposity. Five databases were searched. Studies that reported the effects of replacing sedentary behaviour with light-intensity physical activity (LIPA) and/or moderate-to-vigorous physical activity (MVPA) on at least one adiposity parameter. The estimated regression coefficients (β) and 95% CIs were combined and meta-analysed. Data from 7,351 youths and five studies were analysed. Pooled analysis from cross-sectional studies shows that replacing sedentary time with LIPA showed no significant associations with any adiposity-related outcomes. Replacing sedentary time with MVPA was statistically associated with total body fat percentage (β = -2.512; p = 0.003), but not with body mass index or waist circumference. In subgroup analysis, the greatest magnitude of association was observed from studies where 60 min of sedentary behaviour was reallocated to 60 min of MVPA (β = -4.535; p < 0.001). Our results highlight the importance of promoting MVPA, which may improve body composition phenotypes in young people. This information can be used to develop more effective lifestyle interventions. © 2017 World Obesity Federation.

  5. [Analysis of the PNIF measurement (Peak Nas Inspiratory Flow) in ECAP study (The Epidemiology of Allergic Diseases in Poland)].

    PubMed

    Modzelewska, Dominika; Krzych-Fałta, Edyta; Lusawa, Adam; Samoliński, Bolesław

    2012-01-01

    Measurement of PNIF is often used as a indicator in provocation studies or used for assessment the therapeutic effect of medicines. Unfortunately, there is a lack of norm for this parameter. Therefore, the aim of this study was to assess a few variables which are advisable to estimate the norm for PNIF measurements. The study was a part of the ECAP study (The Epidemiology of Allergic Diseases in Poland). Study group was selected randomly: children aged 6-7, 13-14 and adults. Subjects were inhabitants of 8 cities: Białystok, Gdańsk, Katowice, Kraków, Lublin, Poznań, Warszawa i Wrocław and one village district: zamojski and krasnystawski. PNIF level had been measured among qualified respondents by In-Check inspiratory flow meter manufactured by Clement. Clark. PNIF level was measured before and after application of Oxalin (0,05%) aimed at improve patency of nasal passages. The study was conducted three times, the highest value was noted. There were 4674 qualified subjects, of which 27,6% were children aged 6-7, 27,7%-children aged 13-14 and 44,7%-adults. Results were quantified by Statistica 10 programme and Microsoft Excel programme. Analysis were conducted in regards of sex, age, health status and study area. SEX: Statistically significant higher level of PNIF, as before as after application of medicine, were observed among man than woman. Average level of PNIF after application of medicine among adult man were 151,99 l/min (SD=61,73 l/min), boys aged 13-14-127,62 l/min (SD=53,0), boys aged 6-7- 54,44 l/min (SD=33,44 l/min). Average level of PNIF after application of medicine among adult woman were 119,31 l/min (SD= 45,71 l/min), girls aged 13-14- 109,13 l/min (SD=42,86 l/ min), girls aged 6-7- 61,35 l/min (SD= 31,56 l/min). AGE: There was observed statistically significant difference between age's groups. Average level of PNIF among adults were 131,91 l/min (SD=54,82 l/min), children aged 13-14- 118,68 l/min (SD=49,23 l/min), children aged 6-7- 64,27 l/min (SD=32,64 l/min). Health status: Statistically significant higher level of PNIF were observed among healthy people than sick subjects, among all age's group, except among children aged 6-7. Average level of PNIF, after application of medicine were following: among adults: sick - 128,94 l/min (SD=54,66 l/min), healthy-134,94 l/min (SD=54,84 l/min), children aged 13-14: sick- 116,73 l/min (SD=48,48 l/min), healthy- 120,68 l/min (SD=49,92 l/min) and children aged 6-7: sick- 64,8 l/min (SD=32,25 l/min), healthy- 63,79 l/min (SD=33,0 l/min). Also there was noted statistically significant difference between subject with periodic allergic rhinitis than chronic allergic rhinitis. Statistically significant higher level of PNIF was observed among subjects living in urban area than rural area, as before as after application of medicine, among all age's groups. There were found statistically significant differences between age, sex, health status and study area. PNIF measurement is valuable study assessing. PNIF measurement is valuable parameter assessing rhinitis status.

  6. Temporal rainfall disaggregation using a multiplicative cascade model for spatial application in urban hydrology

    NASA Astrophysics Data System (ADS)

    Müller, H.; Haberlandt, U.

    2018-01-01

    Rainfall time series of high temporal resolution and spatial density are crucial for urban hydrology. The multiplicative random cascade model can be used for temporal rainfall disaggregation of daily data to generate such time series. Here, the uniform splitting approach with a branching number of 3 in the first disaggregation step is applied. To achieve a final resolution of 5 min, subsequent steps after disaggregation are necessary. Three modifications at different disaggregation levels are tested in this investigation (uniform splitting at Δt = 15 min, linear interpolation at Δt = 7.5 min and Δt = 3.75 min). Results are compared both with observations and an often used approach, based on the assumption that a time steps with Δt = 5.625 min, as resulting if a branching number of 2 is applied throughout, can be replaced with Δt = 5 min (called the 1280 min approach). Spatial consistence is implemented in the disaggregated time series using a resampling algorithm. In total, 24 recording stations in Lower Saxony, Northern Germany with a 5 min resolution have been used for the validation of the disaggregation procedure. The urban-hydrological suitability is tested with an artificial combined sewer system of about 170 hectares. The results show that all three variations outperform the 1280 min approach regarding reproduction of wet spell duration, average intensity, fraction of dry intervals and lag-1 autocorrelation. Extreme values with durations of 5 min are also better represented. For durations of 1 h, all approaches show only slight deviations from the observed extremes. The applied resampling algorithm is capable to achieve sufficient spatial consistence. The effects on the urban hydrological simulations are significant. Without spatial consistence, flood volumes of manholes and combined sewer overflow are strongly underestimated. After resampling, results using disaggregated time series as input are in the range of those using observed time series. Best overall performance regarding rainfall statistics are obtained by the method in which the disaggregation process ends at time steps with 7.5 min duration, deriving the 5 min time steps by linear interpolation. With subsequent resampling this method leads to a good representation of manhole flooding and combined sewer overflow volume in terms of hydrological simulations and outperforms the 1280 min approach.

  7. Is questionnaire-based sitting time inaccurate and can it be improved? A cross-sectional investigation using accelerometer-based sitting time

    PubMed Central

    Gupta, Nidhi; Christiansen, Caroline Stordal; Hanisch, Christiana; Bay, Hans; Burr, Hermann; Holtermann, Andreas

    2017-01-01

    Objectives To investigate the differences between a questionnaire-based and accelerometer-based sitting time, and develop a model for improving the accuracy of questionnaire-based sitting time for predicting accelerometer-based sitting time. Methods 183 workers in a cross-sectional study reported sitting time per day using a single question during the measurement period, and wore 2 Actigraph GT3X+ accelerometers on the thigh and trunk for 1–4 working days to determine their actual sitting time per day using the validated Acti4 software. Least squares regression models were fitted with questionnaire-based siting time and other self-reported predictors to predict accelerometer-based sitting time. Results Questionnaire-based and accelerometer-based average sitting times were ≈272 and ≈476 min/day, respectively. A low Pearson correlation (r=0.32), high mean bias (204.1 min) and wide limits of agreement (549.8 to −139.7 min) between questionnaire-based and accelerometer-based sitting time were found. The prediction model based on questionnaire-based sitting explained 10% of the variance in accelerometer-based sitting time. Inclusion of 9 self-reported predictors in the model increased the explained variance to 41%, with 10% optimism using a resampling bootstrap validation. Based on a split validation analysis, the developed prediction model on ≈75% of the workers (n=132) reduced the mean and the SD of the difference between questionnaire-based and accelerometer-based sitting time by 64% and 42%, respectively, in the remaining 25% of the workers. Conclusions This study indicates that questionnaire-based sitting time has low validity and that a prediction model can be one solution to materially improve the precision of questionnaire-based sitting time. PMID:28093433

  8. Lean processes for optimizing OR capacity utilization: prospective analysis before and after implementation of value stream mapping (VSM).

    PubMed

    Schwarz, Patric; Pannes, Klaus Dieter; Nathan, Michel; Reimer, Hans Jorg; Kleespies, Axel; Kuhn, Nicole; Rupp, Anne; Zügel, Nikolaus Peter

    2011-10-01

    The decision to optimize the processes in the operating tract was based on two factors: competition among clinics and a desire to optimize the use of available resources. The aim of the project was to improve operating room (OR) capacity utilization by reduction of change and throughput time per patient. The study was conducted at Centre Hospitalier Emil Mayrisch Clinic for specialized care (n = 618 beds) Luxembourg (South). A prospective analysis was performed before and after the implementation of optimized processes. Value stream analysis and design (value stream mapping, VSM) were used as tools. VSM depicts patient throughput and the corresponding information flows. Furthermore it is used to identify process waste (e.g. time, human resources, materials, etc.). For this purpose, change times per patient (extubation of patient 1 until intubation of patient 2) and throughput times (inward transfer until outward transfer) were measured. VSM, change and throughput times for 48 patient flows (VSM A(1), actual state = initial situation) served as the starting point. Interdisciplinary development of an optimized VSM (VSM-O) was evaluated. Prospective analysis of 42 patients (VSM-A(2)) without and 75 patients (VSM-O) with an optimized process in place were conducted. The prospective analysis resulted in a mean change time of (mean ± SEM) VSM-A(2) 1,507 ± 100 s versus VSM-O 933 ± 66 s (p < 0.001). The mean throughput time VSM-A(2) (mean ± SEM) was 151 min (±8) versus VSM-O 120 min (±10) (p < 0.05). This corresponds to a 23% decrease in waiting time per patient in total. Efficient OR capacity utilization and the optimized use of human resources allowed an additional 1820 interventions to be carried out per year without any increase in human resources. In addition, perioperative patient monitoring was increased up to 100%.

  9. An online monitor of the oxidative capacity of aerosols (o-MOCA)

    NASA Astrophysics Data System (ADS)

    Eiguren-Fernandez, Arantzazu; Kreisberg, Nathan; Hering, Susanne

    2017-02-01

    The capacity of airborne particulate matter to generate reactive oxygen species (ROS) has been correlated with the generation of oxidative stress both in vitro and in vivo. The cellular damage from oxidative stress, and by implication with ROS, is associated with several common diseases, such as asthma and chronic obstructive pulmonary disease (COPD), and some neurological diseases. Yet currently available chemical and in vitro assays to determine the oxidative capacity of ambient particles require large samples, analyses are typically done offline, and the results are not immediate.Here we report the development of an online monitor of the oxidative capacity of aerosols (o-MOCA) to provide online, time-resolved assessment of the capacity of airborne particles to generate ROS. Our approach combines the Liquid Spot Sampler (LSS), which collects particles directly into small volumes of liquid, and a chemical module optimized for online measurement of the oxidative capacity of aerosol using the dithiothreitol (DTT) assay. The LSS uses a three-stage, laminar-flow water condensation approach to enable the collection of particles as small as 5 nm into liquid. The DTT assay has been improved to allow the online, time-resolved analysis of samples collected with the LSS but could be adapted to other collection methods or offline analysis of liquid extracts.The o-MOCA was optimized and its performance evaluated using the 9,10-phenanthraquinone (PQ) as a standard redox-active compound. Laboratory testing shows minimum interferences or carryover between consecutive samples, low blanks, and a reproducible, linear response between the DTT consumption rate (nmol min-1) and PQ concentration (µM). The calculated limit of detection for o-MOCA was 0.15 nmol min-1. The system was validated with a diesel exhaust particle (DEP) extract, previously characterized and used for the development, improvement, and validation of the standard DTT analysis. The DTT consumption rates (nmol min-1) obtained with the o-MOCA were within experimental uncertainties of those previously reported for these DEP samples. In ambient air testing, the fully automated o-MOCA was run unattended for 3 days with 3 h time resolution and showed a diurnal and daily variability in the measured consumption rates (nmol min-1 m-3).

  10. A preliminary study on determining the time window of hypothermia cerebral protection in rat cortex by laser speckle flowmetry

    NASA Astrophysics Data System (ADS)

    Wang, Wenjia; Li, Qiang; Zeng, Shaoqun; Luo, Qingming; Li, Pengcheng

    2007-02-01

    Laser speckle imaging technique was used to characterize the spatiotemporal changes in cerebral blood flow (CBF) in rat cortex induced by the local ultraprofound hypothermia(0°C) with the duration time of 1 min, 2 min, 5 min, 7 min and 10 min. The experimental results showed significant difference of the spatiotemporal characteristics of changes in CBF between short term and long term of ultraprofound hypothermia. For the short duration of ultraprofound hypothermia (1 min, 2 min and 5 min), the hypothermia cause the CBF decrease firstly, and then the CBF increase rapidly when the temperature is recovered to 37°C, exceeding the baseline level and lasting 10+/-3 min, finally return to the baseline. This trend of changes in CBF is similar in the regions of artery, vein and parenchyma, but with different amplitude. For the duration time of 7 min, the changes in CBF also exhibit the similar decrease induced by ultraprofound hypothermia and the rapid increase induced by the temperature recovering, however the increase does not show the overshoot, but only reach around 75% of the baseline level. For the duration of 10 min of ultraprofound hypothermia, the CBF does not increase rapidly when the temperature is recovered to 37°C, but remains at the low level of CBF for 12+/-2 min, and then increases gradually at artery sites, or increases rapidly and then decrease slightly later at the vein and parenchyma sites. Similar as the case in the duration time of 7 min, the final CBF only recovers to about 75% of the baseline level. The experimental results suggest that the CBF can not recover to the baseline after a long duration of ultraprofound hypothermia longer than 7 min.

  11. Economic and workflow analysis of a blood bank automated system.

    PubMed

    Shin, Kyung-Hwa; Kim, Hyung Hoi; Chang, Chulhun L; Lee, Eun Yup

    2013-07-01

    This study compared the estimated costs and times required for ABO/Rh(D) typing and unexpected antibody screening using an automated system and manual methods. The total cost included direct and labor costs. Labor costs were calculated on the basis of the average operator salaries and unit values (minutes), which was the hands-on time required to test one sample. To estimate unit values, workflows were recorded on video, and the time required for each process was analyzed separately. The unit values of ABO/Rh(D) typing using the manual method were 5.65 and 8.1 min during regular and unsocial working hours, respectively. The unit value was less than 3.5 min when several samples were tested simultaneously. The unit value for unexpected antibody screening was 2.6 min. The unit values using the automated method for ABO/Rh(D) typing, unexpected antibody screening, and both simultaneously were all 1.5 min. The total cost of ABO/Rh(D) typing of only one sample using the automated analyzer was lower than that of testing only one sample using the manual technique but higher than that of testing several samples simultaneously. The total cost of unexpected antibody screening using an automated analyzer was less than that using the manual method. ABO/Rh(D) typing using an automated analyzer incurs a lower unit value and cost than that using the manual technique when only one sample is tested at a time. Unexpected antibody screening using an automated analyzer always incurs a lower unit value and cost than that using the manual technique.

  12. The effectiveness of eucalyptus oil, orange oil, and xylene in dissolving different endodontic sealers.

    PubMed

    Yadav, Hemant Kumar; Yadav, Rakesh Kumar; Chandra, Anil; Thakkar, Rahul Rameshbhai

    2016-01-01

    The objective of this study was to evaluate the dissolution effectiveness of eucalyptus oil, orange oil, xylene, and distilled water on three different endodontic sealers. About 240 samples of root canal sealers (eighty for each sealer) were prepared and divided into four groups of 20 each for immersion in different organic solvents. Each group was further subdivided into two subgroups (n = 10) for 2 and 10 min of immersion time. The mean percentage of weight loss was determined for each sealer in each solvent at both time periods. Data were statistically analyzed by two factor analysis of variance and significance of mean difference was obtained by Tukey's post hoc test (P < 0.05). The lowest level of solubility was observed for Adseal followed by Apexit Plus and Endomethasone N at both time periods in all solvents. Apexit Plus showed no significant (P > 0.05) difference in its dissolution in all the organic solvents except distilled water at both the time periods. The solubility profile of Endomethasone N and Adseal did not differ significantly among eucalyptus oil, orange oil, and xylene at 2 min and between eucalyptus oil and orange oil at 10 min. However, at 10 min, Endomethasone N and Adseal showed a more pronounced solubility in xylene as compared to both eucalyptus oil and orange oil. In general, xylene was the most effective in dissolving root canal sealers than other organic solvents. Essential oils (eucalyptus oil and orange oil) were found similar in their ability to dissolve Apexit Plus and Endomethasone N.

  13. [Resection anastomosis of the small intestine by celioscopy in swine. Comparative experimental study between manual and mechanical anastomosis].

    PubMed

    Noël, P; Fagot, H; Fabre, J M; Mann, C; Quenet, F; Guillon, F; Baumel, H; Domergue, J

    1994-01-01

    Laparoscopic intestinal anastomosis is not very reliable and needs to be evaluate in an experimental model in animals before being performed in man. The purpose of this study was to evaluate the feasibility, efficacy and safety of manual anastomosis comparatively to the standard stapling suture. Twenty female pigs weighing 20 +/- 5 kg. were used for this study. A 5 cm ileal segment resection was performed under laparoscopy. The animals were assigned to 2 groups. Group I: 10 animals underwent end-to-end hand-swen anastomosis with Polyglactin 910, dec 1.5. Group II: 10 animals underwent side-to-side anastomosis using the Endo stapler. Operating time and anastomosis time were compared using the Mann-Whitney test for statistical analysis. On the 15th postoperative day, the animals were sacrificed and the anastomoses were evaluated. There was no operating death in the 2 groups. The operative time was significantly longer in group I than in group II (p < 0.01), with 180 +/- 40 min vs 49 +/- 25 min respectively. This difference was due to the anastomosis time of 130 +/- 40 min vs 16 +/- 6 min respectively (p < 0.01). There was 1 postoperative death related to fistula and peritonitis in group I and none in group II. The post-operative follow-ing showed 5 anastomotic leakages (4 in group I and 1 in group II) and 2 relative stenoses in group I. This study shows the simplicity and rapidity of performing stapling intestinal anastomosis under laparoscopy. Hand-sewn anastomosis is technically more difficult to perform under laparoscopy and requires a greater experience.

  14. Short-term incubation of positive blood cultures in brain-heart infusion broth accelerates identification of bacteria by matrix-assisted laser desorption/ionization time-of-flight mass-spectrometry.

    PubMed

    Torres, Ignacio; Gimenez, Estela; Pascual, Tania; Bueno, Felipe; Huntley, Dixie; Martínez, Mireia; Navarro, David

    2017-12-01

    Fast identification of bacteria directly from positive blood cultures (BCs) by matrix-assisted laser desorption/ionization time-of-flight mass-spectrometry (MALDI-TOF MS) can be achieved either using the MALDI Sepsityper kit (protein extraction method) or after a short-term pre-cultivation step on solid medium. We developed a new method that involves short-term enrichment of positive BCs in brain-heart infusion broth (BHI) prior to MALDI-TOF MS analysis. Eighty-four BCs flagged as positive were included in this study; these were processed in parallel either directly using the MALDI Sepsityper kit or following a short-term culture either in BHI or on Columbia blood agar with 5 % sheep blood (CBA). Bacterial species were successfully identified in 91.6, 89.2 and 65.4 % of cases after pre-cultivation for 4 h in BHI, on CBA, or by using the MALDI Sepsityper kit, respectively. Overall, the mean incubation time to correct identification was shorter when pre-cultures were performed in BHI; the mean time for Gram-negative rods was 78.2 min in BHI and 108.2 min on CBA (P=0.045), and the mean time for Gram-positive cocci was 128.5 min in BHI and 169.6 min on CBA (P=0.013). Short-term enrichment of BCs in BHI accelerates identification of a number of bacterial species by MALDI-TOF MS. Further prospective studies are needed to validate our method and gauge its potential clinical impact on the management of bloodstream bacterial infections.

  15. Association between delay to coronary reperfusion and outcome in patients with acute coronary syndrome undergoing extracorporeal cardiopulmonary resuscitation.

    PubMed

    Kuroki, Norihiro; Abe, Daisuke; Iwama, Toru; Suzuki, Kou; Sugiyama, Kazuhiro; Akashi, Akiko; Hamabe, Yuichi; Aonuma, Kazutaka; Sato, Akira

    2017-05-01

    The prognostic effect of early coronary reperfusion therapy with extracorporeal cardiopulmonary resuscitation (ECPR) in patients with cardiac arrest due to acute coronary syndrome (ACS) has yet to be clarified. We investigated the relationship between time interval from collapse to start of ECPR (CtoE) and coronary reperfusion (CtoR) time and neurological outcome in patients with cardiac arrest due to ACS. A cohort of 119 consecutive patients (63±12 years old) with ACS who underwent ECPR and percutaneous coronary intervention(PCI) at our hospital was registered from January 2005 to June 2016. We analyzed patient clinical outcome, which was defined as survival with good neurological outcome at 30 days. We divided the patients into four groups according to CtoR time: Group 1 (time<60min: n=19), Group 2 (60≤time<90min: n=19), Group 3 (time≥90min: n=70) and Group 4 (unsuccessful coronary reperfusion: n=11). One hundred patients (84%) were successful of PCI. A Kaplan-Meier curve showed that Group 1 had the best outcome among the four groups (good neurological outcome at 30 days; 74% vs 37% vs 23% vs 9%, P<0.0001). In receiver operating characteristics analysis for good neurological outcome at 30 days, the cutoff values for CtoE was 40min. The delay CtoE and CtoR time were independent predictors of poor neurological outcome at 30 days after adjusting multiple confounders (CtoE time; Hazard ratio (HR):1.026, 95% confidential intervals(CI): 1.011-1.042, P=0.001), (CtoR time; HR: 1.004, 95% CI: 1.001-1.008, P=0.020). A shorter CtoE and CtoR predicts better clinical outcome in patients with ACS undergoing ECPR. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Differences of energy expenditure while sitting versus standing: A systematic review and meta-analysis.

    PubMed

    Saeidifard, Farzane; Medina-Inojosa, Jose R; Supervia, Marta; Olson, Thomas P; Somers, Virend K; Erwin, Patricia J; Lopez-Jimenez, Francisco

    2018-03-01

    Background Replacing sitting with standing is one of several recommendations to decrease sedentary time and increase the daily energy expenditure, but the difference in energy expenditure between standing versus sitting has been controversial. This systematic review and meta-analysis aimed to determine this difference. Designs and methods We searched Ovid MEDLINE, Ovid Embase Scopus, Web of Science and Google Scholar for observational and experimental studies that compared the energy expenditure of standing versus sitting. We calculated mean differences and 95% confidence intervals using a random effects model. We conducted different predefined subgroup analyses based on characteristics of participants and study design. Results We identified 658 studies and included 46 studies with 1184 participants for the final analysis. The mean difference in energy expenditure between sitting and standing was 0.15 kcal/min (95% confidence interval (CI) 0.12-0.17). The difference among women was 0.1 kcal/min (95% CI 0.0-0.21), and was 0.19 kcal/min (95% CI 0.05-0.33) in men. Observational studies had a lower difference in energy expenditure (0.11 kcal/min, 95% CI 0.08-0.14) compared to randomised trials (0.2 kcal/min, 95% CI 0.12-0.28). By substituting sitting with standing for 6 hours/day, a 65 kg person will expend an additional 54 kcal/day. Assuming no increase in energy intake, this difference in energy expenditure would be translated into the energy content of about 2.5 kg of body fat mass in 1 year. Conclusions The substitution of sitting with standing could be a potential solution for a sedentary lifestyle to prevent weight gain in the long term. Future studies should aim to assess the effectiveness and feasibility of this strategy.

  17. Determination of Single-Kidney Glomerular Filtration Rate in Human Subjects by Using CT

    PubMed Central

    Kwon, Soon Hyo; Saad, Ahmed; Herrmann, Sandra M.; Textor, Stephen C.

    2015-01-01

    Purpose To test the hypothesis that computed tomography (CT)–derived measurements of single-kidney glomerular filtration rate (GFR) obtained in human subjects with 64-section CT agree with those obtained with iothalamate clearance, a rigorous reference standard. Materials and Methods The institutional review board approved this HIPAA-compliant study, and written informed consent was obtained. Ninety-six patients (age range, 51–73 years; 46 men, 50 women) with essential (n = 56) or renovascular (n = 40) hypertension were prospectively studied in controlled conditions (involving sodium intake and renin-angiotensin blockade). Single-kidney perfusion, volume, and GFR were measured by using multidetector CT time-attenuation curves and were compared with GFR measured by using iothalamate clearance, as assigned to the right and left kidney according to relative volumes. The reproducibility of CT GFR over a 3-month period (n = 21) was assessed in patients with renal artery stenosis who were undergoing stable medical treatment. Statistical analysis included the t test, Wilcoxon signed rank test, linear regression, and Bland-Altman analysis. Results CT GFR values were similar to those of iothalamate clearance (mean ± standard deviation, 38.2 mL/min ± 18 vs 41.6 mL/min ± 17; P = .062). Stenotic kidney CT GFR in patients with renal artery stenosis was lower than contralateral kidney GFR or essential hypertension single-kidney GFR (mean, 23.1 mL/min ± 13 vs 36.9 mL/min ± 17 [P = .0008] and 45.2 mL/min ± 16 [P = .019], respectively), as was iothalamate clearance (mean, 26.9 mL/min ± 14 vs 38.5 mL/min ± 15 [P = .0004] and 49.0 mL/min ± 14 [P = .001], respectively). CT GFR correlated well with iothalamate GFR (linear regression, CT GFR = 0.88*iothalamate GFR, r2 = 0.89, P < .0001), and Bland-Altman analysis was used to confirm the agreement. CT GFR was also moderately reproducible in medically treated patients with renal artery stenosis (concordance coefficient correlation, 0.835) but was unaffected by revascularization (mean, 25.3 mL/min ± 15.2 vs 30.3 mL/min ± 18.5; P = .097). Conclusion CT assessments of single-kidney GFR are reproducible and agree well with a reference standard. CT can be useful to obtain minimally invasive estimates of bilateral single-kidney function in human subjects. © RSNA, 2015 PMID:25848903

  18. Distillation time effect on lavender essential oil yield and composition.

    PubMed

    Zheljazkov, Valtcho D; Cantrell, Charles L; Astatkie, Tess; Jeliazkova, Ekaterina

    2013-01-01

    Lavender (Lavandula angustifolia Mill.) is one of the most widely grown essential oil crops in the world. Commercial extraction of lavender oil is done using steam distillation. The objective of this study was to evaluate the effect of the length of the distillation time (DT) on lavender essential oil yield and composition when extracted from dried flowers. Therefore, the following distillation times (DT) were tested in this experiment: 1.5 min, 3 min, 3.75 min, 7.5 min, 15 min, 30 min, 60 min, 90 min, 120 min, 150 min, 180 min, and 240 min. The essential oil yield (range 0.5-6.8%) reached a maximum at 60 min DT. The concentrations of cineole (range 6.4-35%) and fenchol (range 1.7-2.9%) were highest at the 1.5 min DT and decreased with increasing length of the DT. The concentration of camphor (range 6.6-9.2%) reached a maximum at 7.5-15 min DT, while the concentration of linalool acetate (range 15-38%) reached a maximum at 30 min DT. Results suggest that lavender essential oil yield may not increase after 60 min DT. The change in essential oil yield, and the concentrations of cineole, fenchol and linalool acetate as DT changes were modeled very well by the asymptotic nonlinear regression model. DT may be used to modify the chemical profile of lavender oil and to obtain oils with differential chemical profiles from the same lavender flowers. DT must be taken into consideration when citing or comparing reports on lavender essential oil yield and composition.

  19. Analysis of Running and Technical Performance in Substitute Players in International Male Rugby Union Competition.

    PubMed

    Lacome, Mathieu; Piscione, Julien; Hager, Jean-Philippe; Carling, Christopher

    2016-09-01

    To investigate the patterns and performance of substitutions in 18 international 15-a-side men's rugby union matches. A semiautomatic computerized time-motion system compiled 750 performance observations for 375 players (422 forwards, 328 backs). Running and technical-performance measures included total distance run, high-intensity running (>18.0 km/h), number of individual ball possessions and passes, percentage of passes completed, and number of attempted and percentage of successful tackles. A total of 184 substitutions (85.2%) were attributed to tactical and 32 (14.8%) to injury purposes respectively. The mean period for non-injury-purpose substitutions in backs (17.7%) occurred between 70 and 75 min, while forward substitutions peaked equally between 50-55 and 60-65 min (16.4%). Substitutes generally demonstrated improved running performance compared with both starter players who completed games and players whom they replaced (small differences, ES -0.2 to 0.5) in both forwards and backs over their entire time played. There was also a trend for better running performance in forward and back substitutes over their first 10 min of play compared with the final 10 min for replaced players (small to moderate differences, ES 0.3-0.6). Finally, running performance in both forward and back substitutes was generally lower (ES -0.1 to 0.3, unclear or small differences) over their entire 2nd-half time played compared with their first 10 min of play. The impact of substitutes on technical performance was generally considered unclear. This information provides practitioners with practical data relating to the physical and technical contributions of substitutions that subsequently could enable optimization of their impact on match play.

  20. Effect of limited ischemia time on the amount and function of mitochondria within human skeletal muscle cells.

    PubMed

    Jawhar, A; Ponelies, N; Schild, L

    2016-12-01

    The clinical success of total knee arthroplasty (TKA) depends substantially on the quadriceps muscle function. A frequently applied thigh tourniquet during TKA may induce ischemia related injuries to quadriceps muscle cells. Animal limb muscles subjected to 2-5 h ischemia revealed dysfunctional mitochondria, which in turn compromised the cellular bioenergetics and increased the level of reactive oxygen species. The hypothesis of the present study was that tourniquet application during TKA for 60 min (min) affects the amount and function of mitochondria within musculus vastus medialis cells. In a randomized clinical trial, 10 patients enrolled to undergo primary TKA. The patients were randomly assigned to the tourniquet (n = 5) or non-tourniquet group (n = 5) after obtaining a written informed consent. For each of the groups, the first muscle biopsy was harvested immediately after performing the surgical approach and the second biopsy exactly 60 min later. All biopsies (5 × 5 × 5 mm) 125 mm 3 were harvested from musculus vastus medialis and snap-frozen in liquid nitrogen. The biochemical analysis of the prepared muscle tissues included the measurement of activities of mitochondrial respiratory chain enzyme complexes I-III and citrate synthase. Tourniquet-induced 60 min ischemia time did not significantly change the activities of the mitochondrial respiratory chain enzymes complexes I-III of the skeletal muscle cells. The citrate synthase activities found to be not significantly different between both groups. The use of tourniquet during TKA within a limited time period of 60 min remained without substantial effects on the amount and function of mitochondria within human skeletal muscle cells.

  1. LED therapy or cryotherapy between exercise intervals in Wistar rats: anti-inflammatory and ergogenic effects.

    PubMed

    da Costa Santos, Vanessa Batista; de Paula Ramos, Solange; Milanez, Vinícius Flávio; Corrêa, Julio Cesar Molina; de Andrade Alves, Rubens Igor; Dias, Ivan Frederico Lupiano; Nakamura, Fábio Yuzo

    2014-03-01

    The aim of this study was to test, between two bouts of exercise, the effects of light-emitting diode (LED) therapy and cryotherapy regarding muscle damage, inflammation, and performance. Male Wistar rats were allocated in four groups: control, passive recovery (PR), cryotherapy (Cryo), and LED therapy. The animals were submitted to 45 min of swimming exercise followed by 25 min of recovery and then a second bout of either 45 min of exercise (muscle damage analysis) or time to exhaustion (performance). During the rest intervals, the rats were kept in passive rest (PR), submitted to cold water immersion (10 min, 10 °C) or LED therapy (940 nm, 4 J/cm(2)) of the gastrocnemius muscle. Blood samples were collected to analyze creatine kinase activity (CK), C-reactive protein (CRP), and leukocyte counts. The soleus muscles were evaluated histologically. Time to exhaustion was recorded during the second bout of exercise. After a second bout of 45 min, the results demonstrated leukocytosis in the PR and Cryo groups. Neutrophil counts were increased in all test groups. CK levels were increased in the Cryo group. CRP was increased in PR animals. The PR group presented a high frequency of necrosis, but the LED group had fewer necrotic areas. Edema formation was prevented, and fewer areas of inflammatory cells were observed in the LED group. The time to exhaustion was greater in both the LED and Cryo groups, without differences in CK levels. CRP was decreased in LED animals. We conclude that LED therapy and cryotherapy can improve performance, although LED therapy is more efficient in preventing muscle damage and local and systemic inflammation.

  2. Mechanical strength and hydrophobicity of cotton fabric after SF6 plasma treatment

    NASA Astrophysics Data System (ADS)

    Kamlangkla, K.; Paosawatyanyong, B.; Pavarajarn, V.; Hodak, Jose H.; Hodak, Satreerat K.

    2010-08-01

    Surface treatments to tailor fabric properties are in high demand by the modern garment industry. We studied the effect of radio-frequency inductively coupled SF plasma on the surface characteristics of cotton fabric. The duration of the treatment and the SF pressure were varied systematically. We measured the hydrophobicity of treated cotton as a function of storage time and washing cycles. We used the weight loss (%) along with the etching rate, the tensile strength, the morphology changes and the hydrophobicity of the fabric as observables after treatments with different plasma conditions. The weight loss remains below 1% but it significantly increases when the treatment time is longer than 5 min. Substantial changes in the surface morphology of the fiber are concomitant with the increased etching rate and increased weight loss with measurable consequences in their mechanical characteristics. The measured water absorption time reaches the maximum of 210 min when the SF pressure is higher than 0.3 Torr. The water contact angle ( 149°) and the absorption time (210 min) of cotton treated with extreme conditions appear to be durable as long as the fabric is not washed. X-ray photoelectron spectroscopy analysis reveals that the water absorption time of the fabric follows the same increasing trend as the fluorine/carbon ratio at the fabric surface and atom density of fluorine measured by Ar actinometer.

  3. Combined Effect of Long Processing Time and Na2SiF6 on the Properties of PEO Coatings Formed on AZ91D

    NASA Astrophysics Data System (ADS)

    Rehman, Zeeshan Ur; Koo, Bon Heun

    2016-08-01

    In this study, protective ceramic coatings were prepared on AZ91D magnesium alloy by plasma electrolytic oxidation (PEO) to improve the corrosion and mechanical properties of AZ91D magnesium alloy. The process was conducted in silicate-fluoride-based electrolyte solution. It was found that the average micro-hardness of the coating was significantly increased with an increase in the PEO processing time. The highest value of the average micro-hardness ~1271.2 HV was recorded for 60-min processing time. The phase analysis of the coatings indicated that they were mainly composed of Mg2SiO4, MgO, and MgF2 phases. The surface and cross-sectional study demonstrated that porosity was largely reduced with processing time, together with the change in pore geometry from irregular to spherical shape. The results of the polarization test in 3.5 wt.% NaCl solution revealed that aggressive corrosion took place for 5-min sample; however, the corrosion current was noticeably decreased to 0.43 × 10-7 A/cm2 for the 60-min-coated sample. The superior nobility and hardness for long processing time are suggested to be due to the dense and highly thick coating, coupled with the presence of MgF2 phase.

  4. [Comparison of validity and safety between holmium: YAG laser and traditional surgery in partial nephrectomy].

    PubMed

    Bi, Sheng; Xia, Ming

    2015-08-11

    To compare the validity and safety between holmium: YAG laser and traditional surgery in partial nephrectomy. A total of 28 patients were divided into two groups (holmium: YAG laser group without renal artery clamping and traditional surgery group with renal artery clamping). The intraoperative blood loss, total operative time, renal artery clamping time, postoperative hospital stay, separated renal function, postoperative complications and depth of tissue injury were recorded. The intraoperative blood loss, total operative time, renal artery clamping time, postoperative hospital stay, separated renal function, postoperative complications and depth of tissue injury were 80 ml, 77 min, 0 min, 7.4 days, 35 ml/min, 0, 0.9 cm, respectively, in holmium: YAG laser group. And in traditional surgery group were 69 ml, 111 min, 25.5 min, 7.3 days, 34 ml/min, 0, 2.0 cm, respectively. The differences of total operative time, renal artery clamping time and depth of tissue injury between two groups were statistically significant. The others were not statistically significant. Holmium: YAG laser is effective and safe in partial nephrectomy. It can decrease the total operative time, minimize the warm ischemia time and enlarge the extent of surgical excision.

  5. Evaluation of a new imaging tool for use with major trauma cases in the emergency department.

    PubMed

    Crönlein, Moritz; Holzapfel, Konstantin; Beirer, Marc; Postl, Lukas; Kanz, Karl-Georg; Pförringer, Dominik; Huber-Wagner, Stefan; Biberthaler, Peter; Kirchhoff, Chlodwig

    2016-11-17

    The aim of this study was to evaluate potential benefits of a new diagnostic software prototype (Trauma Viewer, TV) automatically reformatting computed tomography (CT) data on diagnostic speed and quality, compared to CT-image data evaluation using a conventional CT console. Multiple trauma CT data sets were analysed by one expert radiology and one expert traumatology fellow independently twice, once using the TV and once using the secondary conventional CT console placed in the CT control room. Actual analysis time and precision of diagnoses assessment were evaluated. The TV and CT-console results were compared respectively, but also a comparison to the initial multiple trauma CT reports assessed by emergency radiology fellows considered as the gold standard was performed. Finally, design and function of the Trauma Viewer were evaluated in a descriptive manner. CT data sets of 30 multiple trauma patients were enrolled. Mean time needed for analysis of one CT dataset was 2.43 min using the CT console and 3.58 min using the TV respectively. Thus, secondary conventional CT console analysis was on average 1.15 min shorter compared to the TV analysis. Both readers missed a total of 11 diagnoses using the secondary conventional CT console compared to 12 missed diagnoses using the TV. However, none of these overlooked diagnoses resulted in an Abbreviated Injury Scale (AIS) > 2 corresponding to life threatening injuries. Even though it took the two expert fellows a little longer to analyse the CT scans on the prototype TV compared to the CT console, which can be explained by the new user interface of the TV, our preliminary results demonstrate that, after further development, the TV might serve as a new diagnostic feature in the trauma room management. Its high potential to improve time and quality of CT-based diagnoses might help in fast decision making regarding treatment of severely injured patients.

  6. Rapid screening and determination of 11 new psychoactive substances by direct analysis in real time mass spectrometry and liquid chromatography/quadrupole time-of-flight mass spectrometry.

    PubMed

    Nie, Honggang; Li, Xianjiang; Hua, Zhendong; Pan, Wei; Bai, Yanping; Fu, Xiaofang

    2016-08-01

    With the amounts and types of new psychoactive substances (NPSs) increasing rapidly in recent years, an excellent high-throughput method for the analysis of these compounds is urgently needed. In this article, a rapid screening method and a quantitative analysis method for 11 NPSs are described and compared, respectively. A simple direct analysis in real time mass spectrometry (DART-MS) method was developed for the analysis of 11 NPSs including three categories of these substances present on the global market such as four cathinones, one phenylethylamine, and six synthetic cannabinoids. In order to analyze these compounds quantitatively with better accuracy and sensitivity, another rapid analytical method with a low limit of detection (LOD) was also developed using liquid chromatography/electrospray ionization quadrupole time-of-flight mass spectrometry (LC/QTOFMS). The 11 NPSs could be determined within 0.5 min by DART-MS. Furthermore, they could also be separated and determined within 5 min by the LC/QTOFMS method. The two methods both showed good linearity with correlation coefficients (r(2) ) higher than 0.99. The LODs for all these target NPSs by DART-MS and LC/QTOFMS ranged from 5 to 40 ng mL(-1) and 0.1 to 1 ng mL(-1) , respectively. Confiscated samples, named as "music vanilla" and "bath salt", and 11 spiked samples were firstly screened by DART-MS and then determined by LC/QTOFMS. The identification of NPSs in confiscated materials was successfully achieved, and the proposed analytical methodology could offer rapid screening and accurate analysis results. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Modeling short duration extreme precipitation patterns using copula and generalized maximum pseudo-likelihood estimation with censoring

    NASA Astrophysics Data System (ADS)

    Bargaoui, Zoubeida Kebaili; Bardossy, Andràs

    2015-10-01

    The paper aims to develop researches on the spatial variability of heavy rainfall events estimation using spatial copula analysis. To demonstrate the methodology, short time resolution rainfall time series from Stuttgart region are analyzed. They are constituted by rainfall observations on continuous 30 min time scale recorded over a network composed by 17 raingages for the period July 1989-July 2004. The analysis is performed aggregating the observations from 30 min up to 24 h. Two parametric bivariate extreme copula models, the Husler-Reiss model and the Gumbel model are investigated. Both involve a single parameter to be estimated. Thus, model fitting is operated for every pair of stations for a giving time resolution. A rainfall threshold value representing a fixed rainfall quantile is adopted for model inference. Generalized maximum pseudo-likelihood estimation is adopted with censoring by analogy with methods of univariate estimation combining historical and paleoflood information with systematic data. Only pairs of observations greater than the threshold are assumed as systematic data. Using the estimated copula parameter, a synthetic copula field is randomly generated and helps evaluating model adequacy which is achieved using Kolmogorov Smirnov distance test. In order to assess dependence or independence in the upper tail, the extremal coefficient which characterises the tail of the joint bivariate distribution is adopted. Hence, the extremal coefficient is reported as a function of the interdistance between stations. If it is less than 1.7, stations are interpreted as dependent in the extremes. The analysis of the fitted extremal coefficients with respect to stations inter distance highlights two regimes with different dependence structures: a short spatial extent regime linked to short duration intervals (from 30 min to 6 h) with an extent of about 8 km and a large spatial extent regime related to longer rainfall intervals (from 12 h to 24 h) with an extent of 34 to 38 km.

  8. A systematic review and meta-analysis of carbohydrate benefits associated with randomized controlled competition-based performance trials.

    PubMed

    Pöchmüller, Martin; Schwingshackl, Lukas; Colombani, Paolo C; Hoffmann, Georg

    2016-01-01

    Carbohydrate supplements are widely used by athletes as an ergogenic aid before and during sports events. The present systematic review and meta-analysis aimed at synthesizing all available data from randomized controlled trials performed under real-life conditions. MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials were searched systematically up to February 2015. Study groups were categorized according to test mode and type of performance measurement. Subgroup analyses were done with reference to exercise duration and range of carbohydrate concentration. Random effects and fixed effect meta-analyses were performed using the Software package by the Cochrane Collaboration Review Manager 5.3. Twenty-four randomized controlled trials met the objectives and were included in the present systematic review, 16 of which provided data for meta-analyses. Carbohydrate supplementations were associated with a significantly shorter exercise time in groups performing submaximal exercise followed by a time trial [mean difference -0.9 min (95 % confidence interval -1.7, -0.2), p = 0.02] as compared to controls. Subgroup analysis showed that improvements were specific for studies administering a concentration of carbohydrates between 6 and 8 % [mean difference -1.0 min (95 % confidence interval -1.9, -0.0), p = 0.04]. Concerning groups with submaximal exercise followed by a time trial measuring power accomplished within a fixed time or distance, mean power output was significantly higher following carbohydrate load (mean difference 20.2 W (95 % confidence interval 9.0, 31.5), p = 0.0004]. Likewise, mean power output was significantly increased following carbohydrate intervention in groups with time trial measuring power within a fixed time or distance (mean difference 8.1 W (95 % confidence interval 0.5, 15.7) p = 0.04]. Due to the limitations of this systematic review, results can only be applied to a subset of athletes (trained male cyclists). For those, we could observe a potential ergogenic benefit of carbohydrate supplementation especially in a concentration range between 6 and 8 % when exercising longer than 90 min.

  9. A novel Fast Gas Chromatography based technique for higher time resolution measurements of speciated monoterpenes in air

    NASA Astrophysics Data System (ADS)

    Jones, C. E.; Kato, S.; Nakashima, Y.; Kajii, Y.

    2013-12-01

    Biogenic emissions supply the largest fraction of non-methane volatile organic compounds (VOC) from the biosphere to the atmospheric boundary layer, and typically comprise a complex mixture of reactive terpenes. Due to this chemical complexity, achieving comprehensive measurements of biogenic VOC (BVOC) in air within a satisfactory time resolution is analytically challenging. To address this, we have developed a novel, fully automated Fast Gas Chromatography (Fast-GC) based technique to provide higher time resolution monitoring of monoterpenes (and selected other C9-C15 terpenes) during plant emission studies and in ambient air. To our knowledge, this is the first study to apply a Fast-GC based separation technique to achieve quantification of terpenes in air. Three chromatography methods have been developed for atmospheric terpene analysis under different sampling scenarios. Each method facilitates chromatographic separation of selected BVOC within a significantly reduced analysis time compared to conventional GC methods, whilst maintaining the ability to quantify individual monoterpene structural isomers. Using this approach, the C10-C15 BVOC composition of single plant emissions may be characterised within a ~ 14 min analysis time. Moreover, in situ quantification of 12 monoterpenes in unpolluted ambient air may be achieved within an ~ 11 min chromatographic separation time (increasing to ~ 19 min when simultaneous quantification of multiple oxygenated C9-C10 terpenoids is required, and/or when concentrations of anthropogenic VOC are significant). This corresponds to a two- to fivefold increase in measurement frequency compared to conventional GC methods. Here we outline the technical details and analytical capability of this chromatographic approach, and present the first in situ Fast-GC observations of 6 monoterpenes and the oxygenated BVOC linalool in ambient air. During this field deployment within a suburban forest ~ 30 km west of central Tokyo, Japan, the Fast-GC limit of detection with respect to monoterpenes was 4-5 ppt, and the agreement between Fast-GC and PTR-MS derived total monoterpene mixing ratios was consistent with previous GC/PTR-MS comparisons. The measurement uncertainties associated with the Fast-GC quantification of monoterpenes are ≤ 10%, while larger uncertainties (up to ~ 25%) are associated with the OBVOC and sesquiterpene measurements.

  10. A simple ergonomic measure reduces fluoroscopy time during ERCP: A multivariate analysis.

    PubMed

    Jowhari, Fahd; Hopman, Wilma M; Hookey, Lawrence

    2017-03-01

    Background and study aims  Endoscopic retrograde cholangiopancreatgraphy (ERCP) carries a radiation risk to patients undergoing the procedure and the team performing it. Fluoroscopy time (FT) has been shown to have a linear relationship with radiation exposure during ERCP. Recent modifications to our ERCP suite design were felt to impact fluoroscopy time and ergonomics. This multivariate analysis was therefore undertaken to investigate these effects, and to identify and validate various clinical, procedural and ergonomic factors influencing the total fluoroscopy time during ERCP. This would better assist clinicians with predicting prolonged fluoroscopic durations and to undertake relevant precautions accordingly. Patients and methods  A retrospective analysis of 299 ERCPs performed by 4 endoscopists over an 18-month period, at a single tertiary care center was conducted. All inpatients/outpatients (121 males, 178 females) undergoing ERCP for any clinical indication from January 2012 to June 2013 in the chosen ERCP suite were included in the study. Various predetermined clinical, procedural and ergonomic factors were obtained via chart review. Univariate analyses identified factors to be included in the multivariate regression model with FT as the dependent variable. Results  Bringing the endoscopy and fluoroscopy screens next to each other was associated with a significantly lesser FT than when the screens were separated further (-1.4 min, P  = 0.026). Other significant factors associated with a prolonged FT included having a prior ERCP (+ 1.4 min, P  = 0.031), and more difficult procedures (+ 4.2 min for each level of difficulty, P  < 0.001). ERCPs performed by high-volume endoscopists used lesser FT vs. low-volume endoscopists (-1.82, P = 0.015). Conclusions  Our study has identified and validated various factors that affect the total fluoroscopy time during ERCP. This is the first study to show that decreasing the distance between the endoscopy and fluoroscopy screens in the ERCP suite significantly reduces the total fluoroscopy time, and therefore radiation exposure to patients and staff involved in the procedure.

  11. Second ventilatory threshold from heart-rate variability: valid when the upper body is involved?

    PubMed

    Mourot, Laurent; Fabre, Nicolas; Savoldelli, Aldo; Schena, Federico

    2014-07-01

    To determine the most accurate method based on spectral analysis of heart-rate variability (SA-HRV) during an incremental and continuous maximal test involving the upper body, the authors tested 4 different methods to obtain the heart rate (HR) at the second ventilatory threshold (VT(2)). Sixteen ski mountaineers (mean ± SD; age 25 ± 3 y, height 177 ± 8 cm, mass 69 ± 10 kg) performed a roller-ski test on a treadmill. Respiratory variables and HR were continuously recorded, and the 4 SA-HRV methods were compared with the gas-exchange method through Bland and Altman analyses. The best method was the one based on a time-varying spectral analysis with high frequency ranging from 0.15 Hz to a cutoff point relative to the individual's respiratory sinus arrhythmia. The HR values were significantly correlated (r(2) = .903), with a mean HR difference with the respiratory method of 0.1 ± 3.0 beats/min and low limits of agreements (around -6 /+6 beats/min). The 3 other methods led to larger errors and lower agreements (up to 5 beats/min and around -23/+20 beats/min). It is possible to accurately determine VT(2) with an HR monitor during an incremental test involving the upper body if the appropriate HRV method is used.

  12. SARA South Observations and Analysis of the Solar Type, Totally Eclipsing, Over Contact Binary, PY Aquarii

    NASA Astrophysics Data System (ADS)

    Chamberlain, Heather; Samec, Ronald G.; Caton, Daniel Bruce; Van Hamme, Walter

    2018-01-01

    PY Aqr (GSC 05191-00853) is a solar Type (T ~ 5750K) eclipsing binary. It was observed in July to October, 2017 at Cerro Tololo in remote mode with the 0.6-m SARA South reflector. Two times of minimum light were calculated from our present observations, a primary and a secondary eclipse:HJD Min I = 2457951.7762±0.0006 HJD Min II = 2458019.5295±00.0003. Both weighted as 1.0.In addition, four timings were determined from online data given in IBVS 5600 and five observations at minima were determined from archived All Sky Automated Survey Data:HJD Min I = 2452908.3165, 2452912.33612 HJD Min II = 2452877.5621, 2452913.34465. All weighted as 0.5.ASAS Observations at minima: 2452094.688, 2453478.882, 2453266.576, 2452093.685 and 54729.600. Each weighted as 0.10The following linear and quadratic ephemerides were determined from all available times of minimum light:JD Hel Min I=2452951.7443±0.0008d + 0.402093441±0.000000099 X E {1} JD Hel Min I=2452951.7439±0.0007d + 0.4020912±0.0000007 X E +0.00000000018 ± 0.00000000006 X E2 {2}A BVRI Bessell filtered simultaneous Wilson-Devinney Program (W-D) solution reveals that the system has a mass ratio of ~0.34 and a component temperature difference of only ~40 K. One low luminosity (Tfact ~ 0.94, ~66 degree radius) large cool region of spots was iterated on the primary component in the WD Synthetic Light Curve computations. It appears in the Southern Hemisphere (colatitude 155 degrees). The Roche Lobe fill-out of the binary is ~17%. The inclination is ~86 degrees. An eclipse duration of ~10 minutes was determined for the primary eclipse and the light curve solution. Additional and more detailed information is given in this report.

  13. Design and Uncertainty Analysis for a PVTt Gas Flow Standard

    PubMed Central

    Wright, John D.; Johnson, Aaron N.; Moldover, Michael R.

    2003-01-01

    A new pressure, volume, temperature, and, time (PVTt) primary gas flow standard at the National Institute of Standards and Technology has an expanded uncertainty (k = 2) of between 0.02 % and 0.05 %. The standard spans the flow range of 1 L/min to 2000 L/min using two collection tanks and two diverter valve systems. The standard measures flow by collecting gas in a tank of known volume during a measured time interval. We describe the significant and novel features of the standard and analyze its uncertainty. The gas collection tanks have a small diameter and are immersed in a uniform, stable, thermostatted water bath. The collected gas achieves thermal equilibrium rapidly and the uncertainty of the average gas temperature is only 7 mK (22 × 10−6 T). A novel operating method leads to essentially zero mass change in and very low uncertainty contributions from the inventory volume. Gravimetric and volume expansion techniques were used to determine the tank and the inventory volumes. Gravimetric determinations of collection tank volume made with nitrogen and argon agree with a standard deviation of 16 × 10−6 VT. The largest source of uncertainty in the flow measurement is drift of the pressure sensor over time, which contributes relative standard uncertainty of 60 × 10−6 to the determinations of the volumes of the collection tanks and to the flow measurements. Throughout the range 3 L/min to 110 L/min, flows were measured independently using the 34 L and the 677 L collection systems, and the two systems agreed within a relative difference of 150 × 10−6. Double diversions were used to evaluate the 677 L system over a range of 300 L/min to 1600 L/min, and the relative differences between single and double diversions were less than 75 × 10−6. PMID:27413592

  14. Removal of Methylene Blue and Orange-G from Waste Water Using Magnetic Biochar

    NASA Astrophysics Data System (ADS)

    Mubarak, N. M.; Fo, Y. T.; Al-Salim, Hikmat Said; Sahu, J. N.; Abdullah, E. C.; Nizamuddin, S.; Jayakumar, N. S.; Ganesan, P.

    2015-04-01

    The study on the removal of methylene blue (MB) and orange-G dyes using magnetic biochar derived from the empty fruit bunch (EFB) was carried out. Process parameters such as pH, adsorbent dosage, agitation speed and contact time were optimized using Design-Expert Software v.6.0.8. The statistical analysis reveals that the optimum conditions for the maximum adsorption of MB are at pH 2 and pH 10, dosage 1.0 g, and agitation speed and contact time of 125 rpm and 120 min respectively. While for orange-G, at pH 2, dosage 1.0 g, and agitation speed and contact time of 125 rpm and 120 min respectively. The maximum adsorption capacity of 31.25 mg/g and 32.36 mg/g for MB and orange-G respectively. The adsorption kinetic for both dyes obeyed pseudo-second order.

  15. Comparison of Hemostasis Times With a Kaolin-Based Hemostatic Pad (QuikClot Radial) vs Mechanical Compression (TR Band) Following Transradial Access: A Pilot Prospective Study.

    PubMed

    Roberts, Jonathan S; Niu, Jianli; Pastor-Cervantes, Juan A

    2017-10-01

    Hemostasis following transradial access (TRA) is usually achieved by mechanical compression. We investigated use of the QuikClot Radial hemostasis pad (Z-Medica) compared with the TR Band (Terumo Medical) to shorten hemostasis after TRA. Thirty patients undergoing TRA coronary angiography and/or percutaneous coronary intervention were randomized into three cohorts post TRA: 10 patients received mechanical compression with the TR Band, 10 patients received 30 min of compression with the QuikClot Radial pad, and 10 patients received 60 min of compression with the QuikClot Radial pad. Times to hemostasis and access-site complications were recorded. Radial artery patency was evaluated 1 hour after hemostasis by the reverse Barbeau's test. There were no differences in patient characteristics, mean dose of heparin (7117 ± 1054 IU), or mean activated clotting time value (210 ± 50 sec) at the end of procedure among the three groups. Successful hemostasis was achieved in 100% of patients with both the 30-min and 60-min compression groups using the QuikClot pad. Hemostasis failure occurred in 50% of patients when the TR Band was initially weaned at the protocol-driven time (40 min after sheath removal). Mean compression time for hemostasis with the TR Band was 149.4 min compared with 30.7 min and 60.9 min for the 30-min and 60-min QuikClot groups, respectively. No radial artery occlusion occurred in any subject at the end of the study. Use of the QuikClot Radial pad following TRA in this pilot trial significantly shortened hemostasis times when compared with the TR Band, with no increased complications noted.

  16. Global Statistical Maps of Extreme-Event Magnetic Observatory 1 Min First Differences in Horizontal Intensity

    NASA Technical Reports Server (NTRS)

    Love, Jeffrey J.; Coïsson, Pierdavide; Pulkkinen, Antti

    2016-01-01

    Analysis is made of the long-term statistics of three different measures of ground level, storm time geomagnetic activity: instantaneous 1 min first differences in horizontal intensity (delta)Bh, the root-mean-square of 10 consecutive 1 min differences S, and the ramp change R over 10 min. Geomagnetic latitude maps of the cumulative exceedances of these three quantities are constructed, giving the threshold(nTmin) for which activity within a 24 h period can be expected to occur once per year, decade, and century. Specifically, at geomagnetic 55deg, we estimate once-per-century (delta)Bh, S, and R exceedances and a site-to-site,proportional, 1 standard deviation range [1(sigma), lower and upper] to be, respectively, 1000, [690, 1450]; 500,[350, 720]; and 200, [140, 280] nTmin. At 40deg, we estimate once-per-century (delta)Bh, S, and R exceedances and1(sigma) values to be 200, [140, 290]; 100, [70, 140]; and 40, [30, 60] nTmin.

  17. Optical coherence tomography analysis of hydrofluoric acid decontamination of human cornea by mannitol solution.

    PubMed

    Nosé, Ricardo M; Daga, Fabio B; Nosé, Walton; Kasahara, Niro

    2017-03-01

    To evaluate the efficacy of mannitol solution as a decontamination agent on the chemical burn of the human corneas. Eight donor corneas from an eye bank were exposed to 25μl of 2.5% hydrofluoric acid (HF) solution on a filter paper for 20s. Three eyes were rinsed with 1000ml of mannitol 20% for 15min immediately after removal of the filter paper, 3 other were rinsed with sodium chloride (NaCl) 0.9% (1000ml for 15min) and two eyes were not rinsed. Microstructural changes were monitored in the time domain by optical coherence tomography (OCT) imaging for 75min. NaCl reduced the penetration depth to approximately half the thickness of the cornea at 15min; scattering within the anterior cornea was higher than that for the unrinsed eye. With mannitol, no increased scattering was observed in the posterior part of the corneal stroma within a time period of 1h after rinsing. OCT images revealed low-scattering intensity within the anterior stroma at the end of the rinsing period. In eye bank human corneas, mannitol proved to be an efficient agent to decontaminate HF burn. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  18. Laboratory Automation and Intra-Laboratory Turnaround Time: Experience at the University Hospital Campus Bio-Medico of Rome.

    PubMed

    Angeletti, Silvia; De Cesaris, Marina; Hart, Jonathan George; Urbano, Michele; Vitali, Massimiliano Andrea; Fragliasso, Fulvio; Dicuonzo, Giordano

    2015-12-01

    Intra-laboratory turnaround time (TAT) is a key indicator of laboratory performance. Improving TAT is a complex task requiring staff education, equipment acquisition, and adequate TAT monitoring. The aim of the present study was to evaluate the intra-laboratory TAT after laboratory automation implementation (June 2013-June 2014) and to compare it to that in the preautomation period (July 2012-May 2013). Intra-laboratory TAT was evaluated both as the mean TAT registered and the percentage of outlier (OP) exams. The mean TAT was 36, 38, and 34 min during the study periods, respectively. These values respected the goal TAT established at 45 min. The OP, calculated at 45 min as well as at 60 min, decreased from 26 to 21 and from 11 to 5, respectively. From a focused analysis on blood count cell, troponin I, and prothrombin (PT) test, TAT improvement was more evident for tests requiring longer preanalytical process. The follow-up of TAT from June 2013 to June 2014 revealed the reduction of the mean TAT as well as of the OP exams after automation implementation and that automation more strongly affects the test in the preanalytical phase including centrifugation of the sample, such as troponin I and PT. © 2015 Society for Laboratory Automation and Screening.

  19. Laser Guidance in C-Arm Cone-Beam CT-Guided Radiofrequency Ablation of Osteoid Osteoma Reduces Fluoroscopy Time

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kroes, Maarten W., E-mail: Maarten.Kroes@radboudumc.nl; Busser, Wendy M. H.; Hoogeveen, Yvonne L.

    PurposeTo assess whether laser guidance can reduce fluoroscopy and procedure time of cone-beam computed tomography (CBCT)-guided radiofrequency (RF) ablations of osteoid osteoma compared to freehand CBCT guidance.Materials and Methods32 RF ablations were retrospectively analyzed, 17 laser-guided and 15 procedures using the freehand technique. Subgroup selection of 18 ablations in the hip–pelvic region with a similar degree of difficulty was used for a direct comparison. Data are presented as median (ranges).ResultsComparison of all 32 ablations resulted in fluoroscopy times of 365 s (193–878 s) for freehand and 186 s (75–587 s) for laser-guided procedures (p = 0.004). Corresponding procedure times were 56 min (35–97 min) and 52 min (30–85 min) (p = 0.355).more » The subgroup showed comparable target sizes, needle path lengths, and number of scans between groups. Fluoroscopy times were lower for laser-guided procedures, 215 s (75–413 s), compared to 384 s (193–878 s) for freehand (p = 0.012). Procedure times were comparable between groups, 51 min (30–72 min) for laser guidance and 58 min (35–79 min) for freehand (p = 0.172).ConclusionAdding laser guidance to CBCT-guided osteoid osteoma RF ablations significantly reduced fluoroscopy time without increasing procedure time.Level of EvidenceLevel 4, case series.« less

  20. Time motion and video analysis of classical ballet and contemporary dance performance.

    PubMed

    Wyon, M A; Twitchett, E; Angioi, M; Clarke, F; Metsios, G; Koutedakis, Y

    2011-11-01

    Video analysis has become a useful tool in the preparation for sport performance and its use has highlighted the different physiological demands of seemingly similar sports and playing positions. The aim of the current study was to examine the performance differences between classical ballet and contemporary dance. In total 93 dance performances (48 ballet and 45 contemporary) were analysed for exercise intensity, changes in direction and specific discrete skills (e. g., jumps, lifts). Results revealed significant differences between the 2 dance forms for exercise intensity (p<0.001), changes in direction (p<0.001) and discrete skills (p<0.05) with gender differences noted in the latter (p<0.05). Ballet was characterised by longer periods at rest (38 s x min(-1)) and high to very high exercise intensities (9 s x min(-1)), whilst contemporary dance featured more continuous moderate exercise intensities (27 s x min(-1)). These differences have implications on the energy systems utilised during performance with ballet potentially stressing the anaerobic system more than contemporary dance. The observed high rates in the discrete skills in ballet (5 jumps x min(-1); 2 lifts x min(-1)) can cause local muscular damage, particularly in relatively weaker individuals. In conclusion, classical ballet and contemporary dance performances are as significantly different in the underlying physical demands placed on their performers as the artistic aspects of the choreography. © Georg Thieme Verlag KG Stuttgart · New York.

  1. 4D spiral imaging of flows in stenotic phantoms and subjects with aortic stenosis.

    PubMed

    Negahdar, M J; Kadbi, Mo; Kendrick, Michael; Stoddard, Marcus F; Amini, Amir A

    2016-03-01

    The utility of four-dimensional (4D) spiral flow in imaging of stenotic flows in both phantoms and human subjects with aortic stenosis is investigated. The method performs 4D flow acquisitions through a stack of interleaved spiral k-space readouts. Relative to conventional 4D flow, which performs Cartesian readout, the method has reduced echo time. Thus, reduced flow artifacts are observed when imaging high-speed stenotic flows. Four-dimensional spiral flow also provides significant savings in scan times relative to conventional 4D flow. In vitro experiments were performed under both steady and pulsatile flows in a phantom model of severe stenosis (one inch diameter at the inlet, with 87% area reduction at the throat of the stenosis) while imaging a 6-cm axial extent of the phantom, which included the Gaussian-shaped stenotic narrowing. In all cases, gradient strength and slew rate for standard clinical acquisitions, and identical field of view and resolution were used. For low steady flow rates, quantitative and qualitative results showed a similar level of accuracy between 4D spiral flow (echo time [TE] = 2 ms, scan time = 40 s) and conventional 4D flow (TE = 3.6 ms, scan time = 1:01 min). However, in the case of high steady flow rates, 4D spiral flow (TE = 1.57 ms, scan time = 38 s) showed better visualization and accuracy as compared to conventional 4D flow (TE = 3.2 ms, scan time = 51 s). At low pulsatile flow rates, a good agreement was observed between 4D spiral flow (TE = 2 ms, scan time = 10:26 min) and conventional 4D flow (TE = 3.6 ms, scan time = 14:20 min). However, in the case of high flow-rate pulsatile flows, 4D spiral flow (TE = 1.57 ms, scan time = 10:26 min) demonstrated better visualization as compared to conventional 4D flow (TE = 3.2 ms, scan time = 14:20 min). The feasibility of 4D spiral flow was also investigated in five normal volunteers and four subjects with mild-to-moderate aortic stenosis. The approach achieved TE = 1.68 ms and scan time = 3:44 min. The conventional sequence achieved TE = 2.9 ms and scan time = 5:23 min. In subjects with aortic stenosis, we also compared both MRI methods with Doppler ultrasound (US) in the measurement of peak velocity, time to peak systolic velocity, and eject time. Bland-Altman analysis revealed that, when comparing peak velocities, the discrepancy between Doppler US and 4D spiral flow was significantly less than the discrepancy between Doppler and 4D Cartesian flow (2.75 cm/s vs. 10.25 cm/s), whereas the two MR methods were comparable (-5.75 s vs. -6 s) for time to peak. However, for the estimation of eject time, relative to Doppler US, the discrepancy for 4D conventional flow was smaller than that of 4D spiral flow (-16.25 s vs. -20 s). Relative to conventional 4D flow, 4D spiral flow achieves substantial reductions in both the TE and scan times; therefore, utility for it should be sought in a variety of in vivo and complex flow imaging applications. © 2015 Wiley Periodicals, Inc.

  2. A systematic review and meta-analysis of workplace intervention strategies to reduce sedentary time in white-collar workers.

    PubMed

    Chu, A H Y; Ng, S H X; Tan, C S; Win, A M; Koh, D; Müller-Riemenschneider, F

    2016-05-01

    Prolonged sedentary behaviour has been associated with various detrimental health risks. Workplace sitting is particularly important, providing it occupies majority of total daily sedentary behaviour among desk-based employees. The aim of this systematic review and meta-analysis was to examine the effectiveness of workplace interventions overall, and according to different intervention strategies (educational/behavioural, environmental and multi-component interventions) for reducing sitting among white-collar working adults. Articles published through December 2015 were identified in five online databases and manual searches. Twenty-six controlled intervention studies published between 2003 and 2015 of 4568 working adults were included. All 26 studies were presented qualitatively, and 21 studies with a control group without any intervention were included in the meta-analysis. The pooled intervention effect showed a significant workplace sitting reduction of -39.6 min/8-h workday (95% confidence interval [CI]: -51.7, -27.5), favouring the intervention group. Multi-component interventions reported the greatest workplace sitting reduction (-88.8 min/8-h workday; 95% CI: -132.7, -44.9), followed by environmental (-72.8 min/8-h workday; 95% CI: -104.9, -40.6) and educational/behavioural strategies -15.5 min/8-h workday (95% CI:-22.9,-8.2). Our study found consistent evidence for intervention effectiveness in reducing workplace sitting, particularly for multi-component and environmental strategies. Methodologically rigorous studies using standardized and objectively determined outcomes are warranted. © 2016 World Obesity. © 2016 World Obesity.

  3. [Analysis of triterpenoids in Ganoderma lucidum by microwave-assisted continuous extraction].

    PubMed

    Lu, Yan-fang; An, Jing; Jiang, Ye

    2015-04-01

    For further improving the extraction efficiency of microwave extraction, a microwave-assisted contijuous extraction (MACE) device has been designed and utilized. By contrasting with the traditional methods, the characteristics and extraction efficiency of MACE has also been studied. The method was validated by the analysis of the triterpenoids in Ganoderma lucidum. The extraction conditions of MACE were: using 95% ethanol as solvent, microwave power 200 W and radiation time 14.5 min (5 cycles). The extraction results were subsequently compared with traditional heat reflux extraction ( HRE) , soxhlet extraction (SE), ultrasonic extraction ( UE) as well as the conventional microwave extraction (ME). For triterpenoids, the two methods based on the microwaves (ME and MACE) were in general capable of finishing the extraction in 10, 14.5 min, respectively, while other methods should consume 60 min and even more than 100 min. Additionally, ME can produce comparable extraction results as the classical HRE and higher extraction yield than both SE and UE, however, notably lower extraction yield than MASE. More importantly, the purity of the crud extract by MACE is far better than the other methods. MACE can effectively combine the advantages of microwave extraction and soxhlet extraction, thus enabling a more complete extraction of the analytes of TCMs in comparison with ME. And therefore makes the analytic result more accurate. It provides a novel, high efficient, rapid and reliable pretreatment technique for the analysis of TCMs, and it could potentially be extended to ingredient preparation or extracting techniques of TCMs.

  4. Analgesic efficacy and bioavailability of ketorolac in postoperative pain: a probability analysis.

    PubMed

    Pérez-Urizar, J; Granados-Soto, V; Castañeda-Hernández, G; Hong, E; González, C; Martínez, J L; Flores-Murrieta, F J

    2000-01-01

    The analgesic efficacy and bioavailability of 30 mg intramuscular ketorolac was studied in 24 patients with severe or very severe postoperative pain. Pain and pain relief were determined by a five-point verbal rating scale and data were submitted to a probability analysis. Ketorolac plasma levels were determined by high-performance liquid chromatography. Two patients chose not to finish the study; 22 patients completed the study achieving at least good pain relief. Of these 22 patients, 13 reached complete pain relief. Ketorolac was rapidly absorbed. Notwithstanding, pain relief increased gradually, showing considerable delay with regard to plasma concentrations. Analysis of the probability-time curves revealed that 25% of the patients obtained moderate pain relief at 7 min after ketorolac administration, 50% at 11 min, 75% at 29 min, and 95% at 60 min. Good pain relief was achieved in 25, 50, and 75% of the patients at 1.1, 1.8, and 2.7 h, respectively. Complete pain relief was achieved in 25% and 50% of the patients at 2.6 h and 3.7 h, respectively. The probability of exhibiting an acceptable pain relief in responsive patients for more than 5 h was 0.97. No serious side effects were detected. Results show that 30 mg intramuscular ketorolac is an adequate treatment for postoperative pain in the Mexican population. Therefore, the use of higher doses is not justified. Due to gradual installation of analgesia, administration of additional analgesic medication before 1 h is not recommended.

  5. Differences in Spatio-Temporal Behavior of Zebrafish in the Open Tank Paradigm after a Short-Period Confinement into Dark and Bright Environments

    PubMed Central

    Rosemberg, Denis B.; Rico, Eduardo P.; Mussulini, Ben Hur M.; Piato, Ângelo L.; Calcagnotto, Maria E.; Bonan, Carla D.; Dias, Renato D.; Blaser, Rachel E.; Souza, Diogo O.; de Oliveira, Diogo L.

    2011-01-01

    The open tank paradigm, also known as novel tank diving test, is a protocol used to evaluate the zebrafish behavior. Several characteristics have been described for this species, including scototaxis, which is the natural preference for dark environments in detriment of bright ones. However, there is no evidence regarding the influence of “natural stimuli” in zebrafish subjected to novelty-based paradigms. In this report, we evaluated the spatio-temporal exploratory activity of the short-fin zebrafish phenotype in the open tank after a short-period confinement into dark/bright environments. A total of 44 animals were individually confined during a 10-min single session into one of three environments: black-painted, white-painted, and transparent cylinders (dark, bright, and transparent groups). Fish were further subjected to the novel tank test and their exploratory profile was recorded during a 15-min trial. The results demonstrated that zebrafish increased their vertical exploratory activity during the first 6-min, where the bright group spent more time and travelled a higher distance in the top area. Interestingly, all behavioral parameters measured for the dark group were similar to the transparent one. These data were confirmed by automated analysis of track and occupancy plots and also demonstrated that zebrafish display a classical homebase formation in the bottom area of the tank. A detailed spatio-temporal study of zebrafish exploratory behavior and the construction of representative ethograms showed that the experimental groups presented significant differences in the first 3-min vs. last 3-min of test. Although the main factors involved in these behavioral responses still remain ambiguous and require further investigation, the current report describes an alternative methodological approach for assessing the zebrafish behavior after a forced exposure to different environments. Additionally, the analysis of ethologically-relevant patterns across time could be a potential phenotyping tool to evaluate the zebrafish exploratory profile in the open tank task. PMID:21559304

  6. Between-game variation of physical soccer performance measures in highly trained youth soccer players.

    PubMed

    Doncaster, Greg; Unnithan, Viswanath

    2017-07-12

    To assess the between-game variation in measures of physical performance during 11 v 11 soccer match-play, over a short period of time, in highly trained youth soccer players. A single cohort observational study design was employed. Physical match performance data were collected from 17 male, highly trained youth soccer players (age: 13.3 ± 0.4 y) over three, 2 x 20min, 11 v 11 matches. Using 10 Hz GPS, the variables selected for analyses were total distance (TD), high-speed running (HSR), very high-speed running (VHSR), number of high-speed running efforts (HSReff) and number of very high-speed running efforts (VHSReff). Match data was also separated into cumulative 5 min epochs, to identify the peak 5 min epoch and the mean of the cumulative 5 min epochs for each match. Variability was quantified using the coefficient of variation (CV), Standard error of measurement (SEM) and intra-class correlation coefficient (ICC). Between- and within-player smallest worthwhile changes (SWC) were also calculated for each variable to aid in the interpretation of the data. Analysis of the variance between games reported a low CV for TD (3.8%) but larger CVs for HSR (33.3%), HSReff (35.4%) and VHSR and VHSReff (59.6 and 57.4 %, respectively). Analysis of 5 min epochs (peak and average) found an increase in the CVs beyond that of the values reported for the whole match. Between-player SWC in high intensity physical performance data ranged from 24.7 - 42.4 %, whereas within-player SWC ranged from 1.2 - 79.9%. The between-game variability of high and very high intensity activities in youth soccer players, across three soccer matches over a short period of time (2 weeks), is relatively 'large' and specific to the individual, thus highlighting the need for caution when interpreting physical performance data between games and players.

  7. Determination of PNU-248686A, a novel matrix metalloproteinase inhibitor, in human plasma by liquid chromatography-tandem mass spectrometry, following protein precipitation in the 96-well plate format.

    PubMed

    Frigerio, E; Cenacchi, V; James, C A

    2003-02-14

    A sensitive, specific and high-throughput analytical method for the quantitation of PNU-248686A (I), in human plasma has been developed. I, sodium (2R)-3-[[(4'-chloro(1,1'-biphenyl)-4-yl]sulfonyl]-2-hydroxy-2-[(phenylsulfanyl)methyl] propanoate, is an orally active matrix metalloproteinase (MMP) inhibitor developed for the treatment of solid tumors over-expressing MMPs. Concentrations of I, as free acid, were determined in human plasma by LC-MS-MS after plasma protein precipitation in the 96-well plate format. Aliquots of plasma (50 microl) were placed into the plates and 0.2 ml of methanol was added. The plates were shaken for 5 min and centrifuged at 1500 g for 10 min. Aliquots of 10 microl of the supernatants were then directly injected into the LC-MS-MS system. A Symmetry Shield C. column (50 x 2.1 mm, 3.5 microm) was used to perform the chromatographic analysis. The mobile phase was 5 mM ammonium formate buffer solution pH 5.0-acetonitrile (60:40. v/v) with a flow-rate of 0.3 ml/min. Retention time of I was about 1.2 min. Total cycle time was 2.5 min. MS detection used the Applied Biosystems-MDS Sciex API 3000 with TurbolonSpray interface and single reaction monitoring (461 --> 251 m/z transition) operated in negative ion mode. Calibration curves were constructed by plotting the area of the compound (y) against its concentration (x). A weighed linear regression (weighting factor 1/x(2)) was used to calculate I concentrations in quality control and unknown samples. The method was fully validated over the range of 5.0-5000 ng/ml. The suitability and robustness of the method for in vivo samples was confirmed by analysis of plasma samples from a pilot clinical study.

  8. Kinetics of thermal destruction of Salmonella in ground chicken containing trans-cinnamaldehyde and carvacrol.

    PubMed

    Juneja, Vijay K; Yadav, Ajit S; Hwang, Cheng-An; Sheen, Shiowshuh; Mukhopadhyay, Sudarsan; Friedman, Mendel

    2012-02-01

    We investigated the heat resistance of an eight-strain cocktail of Salmonella serovars in chicken supplemented with trans cinnamaldehyde (0 to 1.0%, wt/wt) and carvacrol (0 to 1.0%, wt/wt). Inoculated meat was packaged in bags that were completely immersed in a circulating water bath and held at 55 to 71°C for predetermined lengths of time. The recovery medium was tryptic soy agar supplemented with 0.6% yeast extract and 1% sodium pyruvate. D-values in chicken, determined by linear regression, were 17.45, 2.89, 0.75, and 0.29 min at 55, 60, 65, and 71°C, respectively (z = 9.02°C). Using a survival model for nonlinear survival curves, D-values in chicken ranged from 13.52 min (D(1), major population) and 51.99 min (D(2), heat-resistant subpopulation) at 55°C to 0.15 min (D(1)) and 1.49 min (D(2)) at 71°C. When the Salmonella cocktail was in chicken supplemented with 0.1 to 1.0% trans-cinnamaldehyde or carvacrol, D-values calculated by both approaches were consistently less at all temperatures. This observation suggests that the addition of natural antimicrobials to chicken renders Salmonella serovars more sensitive to the lethal effect of heat. Thermal death times from this study will be beneficial to the food industry in designing hazard analysis and critical control point plans to effectively eliminate Salmonella contamination in chicken products used in this study.

  9. Organizational factors affecting length of stay in the emergency department: initial observational study.

    PubMed

    Bashkin, Osnat; Caspi, Sigalit; Haligoa, Rachel; Mizrahi, Sari; Stalnikowicz, Ruth

    2015-01-01

    Length of stay (LOS) is considered a key measure of emergency department throughput, and from the perspective of the patient, it is perceived as a measure of healthcare service quality. Prolonged LOS can be caused by various internal and external factors. This study examined LOS in the emergency department and explored the main factors that influence LOS and cause delay in patient care. Observations of 105 patients were performed over a 3-month period at the emergency room of a community urban hospital. Observers monitored patients from the moment of entrance to the department until discharge or admission to another hospital ward. Analysis revealed a general average total emergency department LOS of 438 min. Significant differences in average LOS were found between admitted patients (Mean = 544 min, SD = 323 min) and discharged patients (Mean = 291 min, SD = 286 min). In addition, nurse and physician change of shifts and admissions to hospital wards were found to be significant factors associated with LOS. Using an Ishikawa causal diagram, we explored various latent organizational factors that may prolong this time. The study identified several factors that are associated with high average emergency department LOS. High LOS may lead to increases in expenditures and may have implications for patient safety, whereas certain organizational changes, communication improvement, and time management may have a positive effect on it. Interdisciplinary methods can be used to explore factors causing prolonged emergency department LOS and contribute to a better understanding of them.

  10. Structural analysis of commercial ceramides by gas chromatography-mass spectrometry.

    PubMed

    Bleton, J; Gaudin, K; Chaminade, P; Goursaud, S; Baillet, A; Tchapla, A

    2001-05-11

    A simple method using gas chromatography-mass spectrometry was applied to analyse structures of ceramides. Identification of trimethylsilylated ceramides were obtained in short analysis times (derivatization of ceramides in 30 min at room temperature and 20 min gas chromatography mass spectrometry run) even for complex mixtures. For example in ceramide Type III, 18 peaks were observed which represent 27 various structures. The coeluted compounds were ceramides containing the same functional groups and the same carbon number but with a different distribution on the two alkyl chains of the molecule. They were accurately differentiated by mass spectrometry. Therefore, 83 structures of trimethylsilylated ceramides were identified in 11 different commercial mixtures. For 52 structures of these, mass spectral data were not described in the literature, neither full mass spectra nor characteristic fragments.

  11. Tracer Kinetic Analysis of (S)-¹⁸F-THK5117 as a PET Tracer for Assessing Tau Pathology.

    PubMed

    Jonasson, My; Wall, Anders; Chiotis, Konstantinos; Saint-Aubert, Laure; Wilking, Helena; Sprycha, Margareta; Borg, Beatrice; Thibblin, Alf; Eriksson, Jonas; Sörensen, Jens; Antoni, Gunnar; Nordberg, Agneta; Lubberink, Mark

    2016-04-01

    Because a correlation between tau pathology and the clinical symptoms of Alzheimer disease (AD) has been hypothesized, there is increasing interest in developing PET tracers that bind specifically to tau protein. The aim of this study was to evaluate tracer kinetic models for quantitative analysis and generation of parametric images for the novel tau ligand (S)-(18)F-THK5117. Nine subjects (5 with AD, 4 with mild cognitive impairment) received a 90-min dynamic (S)-(18)F-THK5117 PET scan. Arterial blood was sampled for measurement of blood radioactivity and metabolite analysis. Volume-of-interest (VOI)-based analysis was performed using plasma-input models; single-tissue and 2-tissue (2TCM) compartment models and plasma-input Logan and reference tissue models; and simplified reference tissue model (SRTM), reference Logan, and SUV ratio (SUVr). Cerebellum gray matter was used as the reference region. Voxel-level analysis was performed using basis function implementations of SRTM, reference Logan, and SUVr. Regionally averaged voxel values were compared with VOI-based values from the optimal reference tissue model, and simulations were made to assess accuracy and precision. In addition to 90 min, initial 40- and 60-min data were analyzed. Plasma-input Logan distribution volume ratio (DVR)-1 values agreed well with 2TCM DVR-1 values (R(2)= 0.99, slope = 0.96). SRTM binding potential (BP(ND)) and reference Logan DVR-1 values were highly correlated with plasma-input Logan DVR-1 (R(2)= 1.00, slope ≈ 1.00) whereas SUVr(70-90)-1 values correlated less well and overestimated binding. Agreement between parametric methods and SRTM was best for reference Logan (R(2)= 0.99, slope = 1.03). SUVr(70-90)-1 values were almost 3 times higher than BP(ND) values in white matter and 1.5 times higher in gray matter. Simulations showed poorer accuracy and precision for SUVr(70-90)-1 values than for the other reference methods. SRTM BP(ND) and reference Logan DVR-1 values were not affected by a shorter scan duration of 60 min. SRTM BP(ND) and reference Logan DVR-1 values were highly correlated with plasma-input Logan DVR-1 values. VOI-based data analyses indicated robust results for scan durations of 60 min. Reference Logan generated quantitative (S)-(18)F-THK5117 DVR-1 parametric images with the greatest accuracy and precision and with a much lower white-matter signal than seen with SUVr(70-90)-1 images. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  12. Low cycle fatigue and creep fatigue interaction behavior of 9Cr-0.5Mo-1.8W-V-Nb heat-resistant steel at high temperature

    NASA Astrophysics Data System (ADS)

    Wang, Xiaowei; Zhang, Wei; Gong, Jianming; Wahab, Magd Abdel

    2018-07-01

    In this paper, Low Cycle Fatigue (LCF) and Creep-Fatigue Interaction (CFI) behavior of 9Cr-0.5Mo-1.8 W-V-Nb heat-resistant steel (ASME Grade P92 steel) at elevated temperature of 600 °C are investigated. Strain controlled LCF tests are conducted in fully reversed triangular waveform at different strain amplitudes ranging from 0.2% to 0.8%. CFI tests are conducted at 0.4% strain amplitude in trapezoid waveform with tensile hold time varying from 1 min to 60 min and compressive hold time varying from 1 min to 10 min. During LCF and CFI loadings, the evolution of cyclic stress, mean stress and stress relaxation behavior are investigated. It turns out that the softening behavior and lifetime degradation are dependent on strain amplitude, hold time and hold direction. In addition, the microstructure evolution and fracture behavior are characterized by optical, scanning and transmission electron microscope. The initial rapid softening behavior is attributed to the quick elimination of low angle boundaries, whereas no obvious microstructure alteration appears in the stable stage. Fracture behavior analysis reveals creep voids in long-term CFI tests facilitates the initiation and propagation of secondary cracks. The different responses of outer surface oxidation layer during cycling provides an explanation for severer damage of compressive hold and also accounts for the observed various fracture behavior of failed samples.

  13. Enhanced Ethanol Gas Sensing Properties of SnO2-Core/ZnO-Shell Nanostructures

    PubMed Central

    Tharsika, T.; Haseeb, A. S. M. A.; Akbar, Sheikh A.; Sabri, Mohd Faizul Mohd; Hoong, Wong Yew

    2014-01-01

    An inexpensive single-step carbon-assisted thermal evaporation method for the growth of SnO2-core/ZnO-shell nanostructures is described, and the ethanol sensing properties are presented. The structure and phases of the grown nanostructures are investigated by field-emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM) and X-ray diffraction (XRD) techniques. XRD analysis indicates that the core-shell nanostructures have good crystallinity. At a lower growth duration of 15 min, only SnO2 nanowires with a rectangular cross-section are observed, while the ZnO shell is observed when the growth time is increased to 30 min. Core-shell hierarchical nanostructures are present for a growth time exceeding 60 min. The growth mechanism for SnO2-core/ZnO-shell nanowires and hierarchical nanostructures are also discussed. The sensitivity of the synthesized SnO2-core/ZnO-shell nanostructures towards ethanol sensing is investigated. Results show that the SnO2-core/ZnO-shell nanostructures deposited at 90 min exhibit enhanced sensitivity to ethanol. The sensitivity of SnO2-core/ZnO-shell nanostructures towards 20 ppm ethanol gas at 400 °C is about ∼5-times that of SnO2 nanowires. This improvement in ethanol gas response is attributed to high active sensing sites and the synergistic effect of the encapsulation of SnO2 by ZnO nanostructures. PMID:25116903

  14. Clinical, operational and economic outcomes of point-of-care blood gas analysis in COPD patients.

    PubMed

    Oliver, Paloma; Buno, Antonio; Alvarez-Sala, Rodolfo; Fernandez-Calle, Pilar; Alcaide, Maria Jose; Casitas, Raquel; Garcia-Quero, Cristina; Madero, Rosario; Gomez-Rioja, Ruben; Iturzaeta, Jose Manuel

    2015-04-01

    Arterial blood gas analysis is relevant in chronic obstructive pulmonary disease (COPD) management. The aim of this study was to evaluate whether the use of a blood gas analyzer in pulmonology departments improves the clinical, operational and economic outcomes when compared with clinical laboratory measurements. It is an observational prospective study. 112 patients were selected. After specimen collection, the measurement was performed both in pulmonology office as point-of-care and in laboratory. We evaluated clinical outcomes (modification of the indication of long-term oxygen therapy (LTOT) according to results, changes in blood gas analysis results, relationship of the partial pressure of oxygen (PaO2) obtained in the medical visit and velocity of change of the PaO2, influence of total haemoglobin concentration and the change in PaO2), operational outcomes (turnaround time (TAT) from specimen collection to receiving the blood gas analysis report) and economic outcomes (overall cost per process of patient care). There were discrepancies in the indication of LTOT in 13.4% of patients. All parameters showed changes. PaO2 levels showed changes in 2 ways, though they frequently increase over time. The correlation was not good in the other two clinical outcomes. The median TATs in pulmonology office were 1 min versus 79 in laboratory, with 52 min for specimen preparation and transport and 17 min for TAT intralaboratory. The overall cost for the 112 patients in pulmonology office and laboratory was 16,769.89€ and 22,260.97€ respectively. The use of a blood gas analyzer in a pulmonology office improves clinical, operational and economic outcomes when compared with clinical laboratory. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Chitosan based grey wastewater treatment--a statistical design approach.

    PubMed

    Thirugnanasambandham, K; Sivakumar, V; Prakash Maran, J; Kandasamy, S

    2014-01-01

    In this present study, grey wastewater was treated under different operating conditions such as agitation time (1-3 min), pH (2.5-5.5), chitosan dose (0.3-0.6g/l) and settling time (10-20 min) using response surface methodology (RSM). Four factors with three levels Box-Behnken response surface design (BBD) were employed to optimize and investigate the effect of process variables on the responses such as turbidity, BOD and COD removal. The results were analyzed by Pareto analysis of variance (ANOVA) and second order polynomial models were developed in order to predict the responses. Under the optimum conditions, experimental values such as turbidity (96%), BOD (91%) and COD (73%) removals are closely agreed with predicted values. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. The analysis of axisymmetric viscoelasticity, time-dependent recovery, and hydration in rat tail intervertebral discs by radial compression test.

    PubMed

    Lin, Leou-Chyr; Hedman, Thomas P; Wang, Shyu-Jye; Huoh, Michael; Chang, Shih-Youeng

    2009-05-01

    The goal of this study was to develop a nondestructive radial compression technique and to investigate the viscoelastic behavior of the rat tail disc under repeated radial compression. Rat tail intervertebral disc underwent radial compression relaxation testing and creep testing using a custom-made gravitational creep machine. The axisymmetric viscoelasticity and time-dependent recovery were determined. Different levels of hydration (with or without normal saline spray) were supplied to evaluate the effect of changes in viscoelastic properties. Viscoelasticity was found to be axisymmetric in rat-tail intervertebral discs at four equidistant locations. Complete relaxation recovery was found to take 20 min, whereas creep recovery required 25 min. Hydration was required for obtaining viscoelastic axisymmetry and complete viscoelastic recovery.

  17. Volatile compounds and phenolic composition of virgin olive oil: optimization of temperature and time of exposure of olive pastes to air contact during the mechanical extraction process.

    PubMed

    Servili, Maurizio; Selvaggini, Roberto; Taticchi, Agnese; Esposto, Sonia; Montedoro, GianFrancesco

    2003-12-31

    The operative conditions of malaxation such as temperature and time of exposure of olive pastes to air contact (TEOPAC) affect volatile and phenolic composition of virgin olive oil (VOO) and, as a consequence, its sensory and healthy qualities. In this paper, optimal temperature and TEOPAC during malaxation were studied, in lab scale, in two Italian cultivars using phenolic compounds, volatile composition, and sensory analysis of VOO as markers. The optimal temperature and TEOPAC, selected by response surface modeling,were cultivar-dependent being 30 min of TEOPAC at the lowest temperature investigated (22 degrees C) and 0 min of TEOPAC at 26 degrees C for Frantoio and Moraiolo cultivars, respectively.

  18. Physiological and performance effects of carbohydrate gels consumed prior to the extra-time period of prolonged simulated soccer match-play.

    PubMed

    Harper, Liam D; Briggs, Marc A; McNamee, Ged; West, Daniel J; Kilduff, Liam P; Stevenson, Emma; Russell, Mark

    2016-06-01

    The physiological and performance effects of carbohydrate-electrolyte gels consumed before the 30min extra-time period of prolonged soccer-specific exercise were investigated. Randomised, double-blind, crossover. Eight English Premier League academy soccer players performed 120min of soccer-specific exercise on two occasions while consuming fluid-electrolyte beverages before exercise, at half-time and 90min. Carbohydrate-electrolyte (0.7±0.1gkg(-1) BM) or energy-free placebo gels were consumed ∼5min before extra-time. Blood samples were taken before exercise, at half-time and every 15min during exercise. Physical (15-m and 30-m sprint speed, 30-m sprint maintenance and countermovement jump height) and technical (soccer dribbling) performance was assessed throughout each trial. Carbohydrate-electrolyte gels improved dribbling precision (+29±20%) and raised blood glucose concentrations by 0.7±0.8mmoll(-1) during extra-time (both p<0.01). Supplementation did not affect sprint velocities (15m and 30m), 30-m sprint maintenance or dribbling speed as reductions compared to 0-15min values occurred at 105-120min irrespective of trial (all p<0.05). Plasma osmolality and blood sodium concentrations increased post-exercise vs. the opening 15min (p<0.05) but no effect of supplementation existed. Selected markers of physical performance (jump height, 30-m sprint velocity and 30-m repeated sprint maintenance) also reduced by >3% during half-time (all p<0.05). Carbohydrate-electrolyte gel ingestion raised blood glucose concentrations and improved dribbling performance during the extra-time period of simulated soccer match-play. Supplementation did not attenuate reductions in physical performance and hydration status that occurred during extra-time. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  19. Descriptive analysis of objectively assessed physical activity among talented soccer players: a study of three Norwegian professional football clubs.

    PubMed

    Sæther, Stig Arve; Aspvik, Nils Petter

    2016-01-01

    Talented football players are expected to overcome large training and match loads, indicating a high weekly level of physical activity (PA). With the use of accelerometers, the aim of this study was to objectively describe the players' total time spent in moderate-to-vigorous PA (MVPA), vigorous PA (VPA) and very vigorous PA (VVPA) per day in 1 week. Since high-intensity PA has been highlighted as important in terms of overall PA load, we also included 2 and 4 min bouts of VPA. Data were collected in three junior teams in professional football clubs in March (club 1: 2014, club 2: 2012 and club 3: 2011). A one-way analysis of variance was applied to analyse differences between the three respective clubs. The players averaged 77.2-86.2 min in MVPA, 14.9-18.5 min in VPA and 1.0-3.1 in VVPA per day. While there were no differences in total time spent in MVPA and VPA per day, VVPA was significantly higher in club 1 (p<0.01) compared with clubs 2 and 3. Moreover, when using the VPA bouts, club 3 (p<0.01) achieved significantly more time in this intensity compared with clubs 1 and 2. This study acknowledges the importance of including both club-related and non-club-related PA when analysing talented football players' PA level. We suggest that future studies examining players' PA with accelerometers should emphasise time spent in high-intensity PA and how this is associated with physical overload, psychological burnout and risk of injury.

  20. Descriptive analysis of objectively assessed physical activity among talented soccer players: a study of three Norwegian professional football clubs

    PubMed Central

    Sæther, Stig Arve; Aspvik, Nils Petter

    2017-01-01

    Background Talented football players are expected to overcome large training and match loads, indicating a high weekly level of physical activity (PA). Aims With the use of accelerometers, the aim of this study was to objectively describe the players’ total time spent in moderate-to-vigorous PA (MVPA), vigorous PA (VPA) and very vigorous PA (VVPA) per day in 1 week. Since high-intensity PA has been highlighted as important in terms of overall PA load, we also included 2 and 4 min bouts of VPA. Methods Data were collected in three junior teams in professional football clubs in March (club 1: 2014, club 2: 2012 and club 3: 2011). A one-way analysis of variance was applied to analyse differences between the three respective clubs. Results The players averaged 77.2–86.2 min in MVPA, 14.9–18.5 min in VPA and 1.0–3.1 in VVPA per day. While there were no differences in total time spent in MVPA and VPA per day, VVPA was significantly higher in club 1 (p<0.01) compared with clubs 2 and 3. Moreover, when using the VPA bouts, club 3 (p<0.01) achieved significantly more time in this intensity compared with clubs 1 and 2. Conclusion This study acknowledges the importance of including both club-related and non-club-related PA when analysing talented football players’ PA level. We suggest that future studies examining players’ PA with accelerometers should emphasise time spent in high-intensity PA and how this is associated with physical overload, psychological burnout and risk of injury. PMID:28879031

  1. [Quick Start-up and Sustaining of Shortcut Nitrification in Continuous Flow Reactor].

    PubMed

    Wu, Peng; Zhang Shi-ying; Song, Yin-ling; Xu, Yue-zhong; Shen, Yao-liang

    2016-04-15

    How to achieve fast and stable startup of shortcut nitrification has a very important practical value for treatment of low C/N ratio wastewater. Thus, the quick start-up and sustaining of shortcut nitrification were investigated in continuous flow reactor targeting at the current situation of urban wastewater treatment plant using a continuous flow process. The results showed that quick start-up of shortcut nitrification could be successfully achieved in a continuous flow reactor after 60 days' operation with intermittent aeration and controlling of three stages of stop/aeration time (15 min/45 min, 45 min/45 min and 30 min/30 min). The nitrification rates could reach 90% or 95% respectively, while influent ammonia concentrations were 50 or 100 mg · L⁻¹ with stop/aeration time of 30 min/30 min. In addition, intermittent aeration could inhibit the activity of nitrite oxidizing bacteria (NOB), while short hydraulic retention time (HRT) may wash out NOB. And a combined use of both measures was beneficial to sustain shortcut nitrification.

  2. Locating helicopter emergency medical service bases to optimise population coverage versus average response time.

    PubMed

    Garner, Alan A; van den Berg, Pieter L

    2017-10-16

    New South Wales (NSW), Australia has a network of multirole retrieval physician staffed helicopter emergency medical services (HEMS) with seven bases servicing a jurisdiction with population concentrated along the eastern seaboard. The aim of this study was to estimate optimal HEMS base locations within NSW using advanced mathematical modelling techniques. We used high resolution census population data for NSW from 2011 which divides the state into areas containing 200-800 people. Optimal HEMS base locations were estimated using the maximal covering location problem facility location optimization model and the average response time model, exploring the number of bases needed to cover various fractions of the population for a 45 min response time threshold or minimizing the overall average response time to all persons, both in green field scenarios and conditioning on the current base structure. We also developed a hybrid mathematical model where average response time was optimised based on minimum population coverage thresholds. Seven bases could cover 98% of the population within 45mins when optimised for coverage or reach the entire population of the state within an average of 21mins if optimised for response time. Given the existing bases, adding two bases could either increase the 45 min coverage from 91% to 97% or decrease the average response time from 21mins to 19mins. Adding a single specialist prehospital rapid response HEMS to the area of greatest population concentration decreased the average state wide response time by 4mins. The optimum seven base hybrid model that was able to cover 97.75% of the population within 45mins, and all of the population in an average response time of 18 mins included the rapid response HEMS model. HEMS base locations can be optimised based on either percentage of the population covered, or average response time to the entire population. We have also demonstrated a hybrid technique that optimizes response time for a given number of bases and minimum defined threshold of population coverage. Addition of specialized rapid response HEMS services to a system of multirole retrieval HEMS may reduce overall average response times by improving access in large urban areas.

  3. High performance liquid chromatography time of flight electrospray ionization mass spectrometry for quantification of sesquiterpenes in Chrysanthemi indici Flos active extract

    PubMed Central

    Fu, Ling; Wang, Pan; Sun, Yiqun; Wang, Yangyang; Zhao, Jing; Ye, Yuting; Zhang, Yanbin; Bi, Yuefeng

    2015-01-01

    Background: Chrysanthemi indici Flos, a traditional herbal medicine is used to clearing heat–toxicity, removing the liver fire, and improving eyesight. In our preliminary work, an active extract of CTC in C. An indici Flos with anti-hepatitis B virus and liver protective activity was found by HepG2.2.1.5 test and experiment of protein synthesis in mice's injured liver. In this work, we aimed to study the active faction CTC further by qualitative and quantitative analysis method. Materials and Methods: High performance liquid chromatography time of flight electrospray ionization mass spectrometry (HPLC TOF ESI-MS) analysis method of the CTC was established. Cumambrin A and angeloylcumambrin B in CTC were analyzed by high performance liquid chromatography-ultraviolet-evaporative light scattering detector (HPLC-UV-ELSD) analysis methods. A binary gradient elution program was conducted for chromatographic separation with acetonitrile (A) and ultrapure water (B) as follows: 0–10 min, 42–46% A; 10–20 min, 46–55% A; 20–25 min, 55–60% A; and 25–35 min, 60–75% A. The column temperature and UV wavelength were set at 30°C and 205 nm. Result: Ten constituents including (3R, 5R, 6S, 7S, 10R)-7-(2-hydroxy-2-propyl)-10-methyl-4-methyleneperhy, dronaphthal-ene-3, 5, 6-triol acetone solvate; (+)-edusmance-4, (14)-ene-11, 13-diol; linarin; luteolin; apigenin; tricin; 5, 3’,4’- trimethyl-6,7-dimethoxy flavones; cumambrin A; acacetin; and angeloylcumambrin B in CTC were identified by HPLC TOF ESI-MS. The contents of sesquiterpenes in CTC were decreased by storing years. Conclusions: The results showed that both UV and ELSD methods were feasible, accurate, and the determination results were in good consistency. The contents of two sesquiterpenes decreased with storing years. Two sesquiterpenes could be used as quality control for C. indici flos CTC. PMID:26600718

  4. Trade-offs between commuting time and health-related activities.

    PubMed

    Christian, Thomas J

    2012-10-01

    To further understand documented associations between obesity and urban sprawl, this research describes individuals' trade-offs between health-related activities and commuting time. A cross-section of 24,861 working-age individuals employed full-time and residing in urban counties is constructed from the American Time Use Survey (2003-2010). Data are analyzed using seemingly unrelated regressions to quantify health-related activity decreases in response to additional time spent commuting. Outcomes are total daily minutes spent in physical activity at a moderate or greater intensity, preparing food, eating meals with family, and sleeping. Commuting time is measured as all travel time between home and work and vice versa. The mean commuting time is 62 min daily, the median is 55 min, and 10.1% of workers commute 120 min or more. Spending an additional 60 min daily commuting above average is associated with a 6% decrease in aggregate health-related activities and spending an additional 120 min is associated with a 12% decrease. The greatest percentage of commuting time comes from sleeping time reductions (28-35%). Additionally, larger proportions of commuting time are taken from physical activity and food preparation relative to the mean commuting length: of 60 min spent commuting, 16.1% is taken from physical activity and 4.1% is taken from food preparation; of 120 min commuting, 20.3% is taken from physical activity and 5.6% is taken from food preparation. The results indicate that longer commutes are associated with behavioral patterns which over time may contribute to obesity and other poor health outcomes. These findings will assist both urban planners and researchers wishing to understand time constraints' impacts on health.

  5. A randomized controlled trial of light versus deep propofol sedation for elective outpatient colonoscopy: recall, procedural conditions, and recovery.

    PubMed

    Allen, Megan; Leslie, Kate; Hebbard, Geoffrey; Jones, Ian; Mettho, Tejinder; Maruff, Paul

    2015-11-01

    This study aimed to determine if the incidence of recall was equivalent between light and deep sedation for colonoscopy. Secondary analysis included complications, patient clinical recovery, and post-procedure cognitive impairment. Two hundred patients undergoing elective outpatient colonoscopy were randomized to light (bispectral index [BIS] 70-80) or deep (BIS < 60) sedation with propofol and fentanyl. Recall was assessed by the modified Brice questionnaire, and cognition at baseline and discharge was assessed using a Cogstate test battery. The median (interquartile range [IQR]) BIS values were different in the two groups (69 [65-74] light sedation vs 53 [46-59] deep sedation; P < 0.0001). The incidence of recall was 12% in the light sedation group and 1% in the deep sedation group. The risk difference for recall was 0.11 (90% confidence interval, 0.05 to 0.17) in the intention-to-treat analysis, thus refuting equivalence in recall between light and deep sedation (0.05 significance level; 10% equivalence margin). Overall sedation-related complications were more frequent with deep sedation than with light sedation (66% vs 47%, respectively; P = 0.008). Recovery was more rapid with light sedation than with deep sedation as determined by the mean (SD) time to reach a score of 5 on the Modified Observer's Assessment of Alertness/Sedation Scale [3 (4) min vs 7 (4) min, respectively; P < 0.001] and by the median [IQR] time to readiness for hospital discharge (65 [57-80] min vs 74 [63-86] min, respectively; P = 0.001). The incidence of post-procedural cognitive impairment was similar in those randomized to light (19%) vs deep (16%) sedation (P = 0.554). Light sedation was not equivalent to deep sedation for procedural recall, the spectrum of complications, or recovery times. This study provides evidence to inform discussions with patients about sedation for colonoscopy. This trial was registered at the Australian and New Zealand Clinical Trials Registry, number 12611000320954.

  6. A comparison study on a sulfonated graphene-polyaniline nanocomposite coated fiber for analysis of nicotine in solid samples through the traditional and vacuum-assisted HS-SPME.

    PubMed

    Ghiasvand, Alireza; Koonani, Samira; Yazdankhah, Fatemeh; Farhadi, Saeid

    2018-02-05

    A simple, rapid, and reliable headspace solid-phase microextraction (HS-SPME) procedure, reinforced by applying vacuum in the extraction vial, was developed. It was applied for the extraction of nicotine in solid samples prior to determination by gas chromatography-flame ionization detection (GC-FID). First, the surface of a narrow stainless steel wire was made porous and adhesive by platinization to obtain a durable, higher surface area, and resistant fiber. Then, a thin film of sulfonated graphene/polyaniline (Sulf-G/PANI) nanocomposite was synthesized and simultaneously coated on the platinized fiber using the electrophoretic deposition (EPD) method. It was demonstrated that the extraction efficiency remarkably increased by applying the reduced-pressure condition in the extraction vial. To evaluate the conventional HS-SPME and vacuum-assisted HS-SPME (VA-HS-SPME) platforms, all experimental parameters affecting the extraction efficiency including desorption time and temperature, extraction time and temperature and moisture content of sample matrix were optimized. The highest extraction efficiency was obtained at 60°C, 10min (extraction temperature and time) and 280°C, 2min (desorption condition), for VA-HS-SPME strategy, while for conventional HS-SPME the extraction and desorption conditions found to be 100°C, 30min and 280°C, 2min, respectively. The Sulf-G/PANI coated fiber showed high thermal stability, good chemical/mechanical resistance, and long lifetime. For analysis of nicotine in solid samples using VA-HS-SPME-GC-FID, linear dynamic range (LDR) was 0.01-30μgg -1 (R 2 =0.996), the relative standard deviation (RSD%, n=6), for analyses of 1μgg -1 nicotine was calculated 3.4% and limit of detection (LOD) found to be 0.002μgg -1 . The VA-HS-SPME-GC-FID strategy was successfully carried out for quantitation of nicotine in hair and tobacco real samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Effects of Sprint versus High-Intensity Aerobic Interval Training on Cross-Country Mountain Biking Performance: A Randomized Controlled Trial.

    PubMed

    Inoue, Allan; Impellizzeri, Franco M; Pires, Flávio O; Pompeu, Fernando A M S; Deslandes, Andrea C; Santos, Tony M

    2016-01-01

    The current study compared the effects of high-intensity aerobic training (HIT) and sprint interval training (SIT) on mountain biking (MTB) race simulation performance and physiological variables, including peak power output (PPO), lactate threshold (LT) and onset of blood lactate accumulation (OBLA). Sixteen mountain bikers (mean ± SD: age 32.1 ± 6.4 yr, body mass 69.2 ± 5.3 kg and VO2max 63.4 ± 4.5 mL∙kg(-1)∙min(-1)) completed graded exercise and MTB performance tests before and after six weeks of training. The HIT (7-10 x [4-6 min--highest sustainable intensity / 4-6 min-CR100 10-15]) and SIT (8-12 x [30 s--all-out intensity / 4 min--CR100 10-15]) protocols were included in the participants' regular training programs three times per week. Post-training analysis showed no significant differences between training modalities (HIT vs. SIT) in body mass, PPO, LT or OBLA (p = 0.30 to 0.94). The Cohen's d effect size (ES) showed trivial to small effects on group factor (p = 0.00 to 0.56). The interaction between MTB race time and training modality was almost significant (p = 0.08), with a smaller ES in HIT vs. SIT training (ES = -0.43). A time main effect (pre- vs. post-phases) was observed in MTB race performance and in several physiological variables (p = 0.001 to 0.046). Co-variance analysis revealed that the HIT (p = 0.043) group had significantly better MTB race performance measures than the SIT group. Furthermore, magnitude-based inferences showed HIT to be of likely greater benefit (83.5%) with a lower probability of harmful effects (0.8%) compared to SIT. The results of the current study suggest that six weeks of either HIT or SIT may be effective at increasing MTB race performance; however, HIT may be a preferable strategy. ClinicalTrials.gov NCT01944865.

  8. A surrogate method for comparison analysis of salivary concentrations of Xylitol-containing products

    PubMed Central

    Riedy, Christine A; Milgrom, Peter; Ly, Kiet A; Rothen, Marilynn; Mueller, Gregory; Hagstrom, Mary K; Tolentino, Ernie; Zhou, Lingmei; Roberts, Marilyn C

    2008-01-01

    Background Xylitol chewing gum has been shown to reduce Streptococcus mutans levels and decay. Two studies examined the presence and time course of salivary xylitol concentrations delivered via xylitol-containing pellet gum and compared them to other xylitol-containing products. Methods A within-subjects design was used for both studies. Study 1, adults (N = 15) received three xylitol-containing products (pellet gum (2.6 g), gummy bears (2.6 g), and commercially available stick gum (Koolerz, 3.0 g)); Study 2, a second group of adults (N = 15) received three xylitol-containing products (pellet gum, gummy bears, and a 33% xylitol syrup (2.67 g). For both studies subjects consumed one xylitol product per visit with a 7-day washout between each product. A standardized protocol was followed for each product visit. Product order was randomly determined at the initial visit. Saliva samples (0.5 mL to 1.0 mL) were collected at baseline and up to 10 time points (~16 min in length) after product consumption initiated. Concentration of xylitol in saliva samples was analyzed using high-performance liquid chromatography. Area under the curve (AUC) for determining the average xylitol concentration in saliva over the total sampling period was calculated for each product. Results In both studies all three xylitol products (Study 1: pellet gum, gummy bears, and stick gum; Study 2: pellet gum, gummy bears, and syrup) had similar time curves with two xylitol concentration peaks during the sampling period. Study 1 had its highest mean peaks at the 4 min sampling point while Study 2 had its highest mean peaks between 13 to 16 minutes. Salivary xylitol levels returned to baseline at about 18 minutes for all forms tested. Additionally, for both studies the total AUC for the xylitol products were similar compared to the pellet gum (Study 1: pellet gum – 51.3 μg.min/mL, gummy bears – 59.6 μg.min/mL, and stick gum – 46.4 μg.min/mL; Study 2: pellet gum – 63.0 μg.min/mL, gummy bears – 55.9 μg.min/mL, and syrup – 59.0 μg.min/mL). Conclusion The comparison method demonstrated high reliability and validity. In both studies other xylitol-containing products had time curves and mean xylitol concentration peaks similar to xylitol pellet gum suggesting this test may be a surrogate for longer studies comparing various products. PMID:18267030

  9. Effect of ambient light on the time needed to complete a fetal biophysical profile: A randomized controlled trial.

    PubMed

    Said, Heather M; Gupta, Shweta; Vricella, Laura K; Wand, Katy; Nguyen, Thinh; Gross, Gilad

    2017-10-01

    The objective of this study is to determine whether ambient light serves as a fetal stimulus to decrease the amount of time needed to complete a biophysical profile. This is a randomized controlled trial of singleton gestations undergoing a biophysical profile. Patients were randomized to either ambient light or a darkened room. The primary outcome was the time needed to complete the biophysical profile. Secondary outcomes included total and individual component biophysical profile scores and scores less than 8. A subgroup analysis of different maternal body mass indices was also performed. 357 biophysical profile studies were analyzed. 182 studies were performed with ambient light and 175 were performed in a darkened room. There was no difference in the median time needed to complete the biophysical profile based on exposure to ambient light (6.1min in darkened room versus 6.6min with ambient light; P=0.73). No difference was found in total or individual component biophysical profile scores. Subgroup analysis by maternal body mass index did not demonstrate shorter study times with ambient light exposure in women who were normal weight, overweight or obese. Ambient light exposure did not decrease the time needed to complete the biophysical profile. There was no evidence that ambient light altered fetal behavior observed during the biophysical profile. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Participation and Performance Trends in Triple Iron Ultra-triathlon – a Cross-sectional and Longitudinal Data Analysis

    PubMed Central

    Rüst, Christoph Alexander; Knechtle, Beat; Knechtle, Patrizia; Rosemann, Thomas; Lepers, Romuald

    2012-01-01

    Purpose The aims of the present study were to investigate (i) the changes in participation and performance and (ii) the gender difference in Triple Iron ultra-triathlon (11.4 km swimming, 540 km cycling and 126.6 km running) across years from 1988 to 2011. Methods For the cross-sectional data analysis, the association between with overall race times and split times was investigated using simple linear regression analyses and analysis of variance. For the longitudinal data analysis, the changes in race times for the five men and women with the highest number of participations were analysed using simple linear regression analyses. Results During the studied period, the number of finishers were 824 (71.4%) for men and 80 (78.4%) for women. Participation increased for men (r 2=0.27, P<0.01) while it remained stable for women (8%). Total race times were 2,146 ± 127.3 min for men and 2,615 ± 327.2 min for women (P<0.001). Total race time decreased for men (r 2=0.17; P=0.043), while it increased for women (r 2=0.49; P=0.001) across years. The gender difference in overall race time for winners increased from 10% in 1992 to 42% in 2011 (r 2=0.63; P<0.001). The longitudinal analysis of the five women and five men with the highest number of participations showed that performance decreased in one female (r 2=0.45; P=0.01). The four other women as well as all five men showed no change in overall race times across years. Conclusions Participation increased and performance improved for male Triple Iron ultra-triathletes while participation remained unchanged and performance decreased for females between 1988 and 2011. The reasons for the increase of the gap between female and male Triple Iron ultra-triathletes need further investigations. PMID:23012633

  11. Sodium bicarbonate ingestion and individual variability in time-to-peak pH.

    PubMed

    Sparks, Andy; Williams, Emily; Robinson, Amy; Miller, Peter; Bentley, David J; Bridge, Craig; Mc Naughton, Lars R

    2017-01-01

    This study determined variability in time-to-peak pH after consumption of 300 mg kg - 1 of sodium bicarbonate. Seventeen participants (mean ± SD: age 21.38 ± 1.5 years; mass 75.8 ± 5.8 kg; height 176.8 ± 7.6 cm) reported to the laboratory where a resting capillary sample was taken. Then, 300 mg kg -1 of NaHCO 3 in 450 ml of flavoured water was ingested. Participants rested for 90 min and repeated blood samples were procured at 10 min intervals for 60 min and then every 5 min until 90 min. Blood pH concentrations were measured. Results suggested that time-to-peak pH (64.41 ± 18.78 min) was variable with a range of 10-85 min and a coefficient of variation of 29.16%. A bimodal distribution occurred, at 65 and 75 min. In conclusion, athletes, when using NaHCO 3 as an ergogenic aid, should determine their time-to-peak pH to best utilize the added buffering capacity this substance allows.

  12. Estimation of immunization providers' activities cost, medication cost, and immunization dose errors cost in Iraq.

    PubMed

    Al-lela, Omer Qutaiba B; Bahari, Mohd Baidi; Al-abbassi, Mustafa G; Salih, Muhannad R M; Basher, Amena Y

    2012-06-06

    The immunization status of children is improved by interventions that increase community demand for compulsory and non-compulsory vaccines, one of the most important interventions related to immunization providers. The aim of this study is to evaluate the activities of immunization providers in terms of activities time and cost, to calculate the immunization doses cost, and to determine the immunization dose errors cost. Time-motion and cost analysis study design was used. Five public health clinics in Mosul-Iraq participated in the study. Fifty (50) vaccine doses were required to estimate activities time and cost. Micro-costing method was used; time and cost data were collected for each immunization-related activity performed by the clinic staff. A stopwatch was used to measure the duration of activity interactions between the parents and clinic staff. The immunization service cost was calculated by multiplying the average salary/min by activity time per minute. 528 immunization cards of Iraqi children were scanned to determine the number and the cost of immunization doses errors (extraimmunization doses and invalid doses). The average time for child registration was 6.7 min per each immunization dose, and the physician spent more than 10 min per dose. Nurses needed more than 5 min to complete child vaccination. The total cost of immunization activities was 1.67 US$ per each immunization dose. Measles vaccine (fifth dose) has a lower price (0.42 US$) than all other immunization doses. The cost of a total of 288 invalid doses was 744.55 US$ and the cost of a total of 195 extra immunization doses was 503.85 US$. The time spent on physicians' activities was longer than that spent on registrars' and nurses' activities. Physician total cost was higher than registrar cost and nurse cost. The total immunization cost will increase by about 13.3% owing to dose errors. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Effect of intrinsic motivation on affective responses during and after exercise: latent curve model analysis.

    PubMed

    Shin, Myoungjin; Kim, Inwoo; Kwon, Sungho

    2014-12-01

    Understanding the relationship between affect and exercise is helpful in predicting human behavior with respect to exercise participation. The goals of the present study were to investigate individual differences in affective response during and after exercise and to identify the role of intrinsic motivation in affective changes. 30 active male college students (M age = 21.4 yr.) who regularly participated in sports activities volunteered to answer a questionnaire measuring intrinsic motivation toward running activities and performed a 20-min. straight running protocol at heavy intensity (about 70% of VO2max). Participants' affective responses were measured every 5 min. from the beginning of the run to 10 min. after completing the run. Latent curve model analysis indicated that individuals experienced different changes in affective state during exercise, moderated by intrinsic motivation. Higher intrinsic motivation was associated with more positive affect during exercise. There were no significant individual differences in the positive tendency of the participants' affective responses after exercise over time. Intrinsic motivation seems to facilitate positive feelings during exercise and encourages participation in exercise.

  14. Validation of an ultra-fast UPLC-UV method for the separation of antituberculosis tablets.

    PubMed

    Nguyen, Dao T-T; Guillarme, Davy; Rudaz, Serge; Veuthey, Jean-Luc

    2008-04-01

    A simple method using ultra performance LC (UPLC) coupled with UV detection was developed and validated for the determination of antituberculosis drugs in combined dosage form, i. e. isoniazid (ISN), pyrazinamide (PYR) and rifampicin (RIF). Drugs were separated on a short column (2.1 mm x 50 mm) packed with 1.7 mum particles, using an elution gradient procedure. At 30 degrees C, less than 2 min was necessary for the complete separation of the three antituberculosis drugs, while the original USP method was performed in 15 min. Further improvements were obtained with the combination of UPLC and high temperature (up to 90 degrees C), namely HT-UPLC, which allows the application of higher mobile phase flow rates. Therefore, the separation of ISN, PYR and RIF was performed in less than 1 min. After validation (selectivity, trueness, precision and accuracy), both methods (UPLC and HT-UPLC) have proven suitable for the routine quality control analysis of antituberculosis drugs in combined dosage form. Additionally, a large number of samples per day can be analysed due to the short analysis times.

  15. An Accelerated Analytical Process for the Development of STR Profiles for Casework Samples.

    PubMed

    Laurin, Nancy; Frégeau, Chantal J

    2015-07-01

    Significant efforts are being devoted to the development of methods enabling rapid generation of short tandem repeat (STR) profiles in order to reduce turnaround times for the delivery of human identification results from biological evidence. Some of the proposed solutions are still costly and low throughput. This study describes the optimization of an analytical process enabling the generation of complete STR profiles (single-source or mixed profiles) for human identification in approximately 5 h. This accelerated process uses currently available reagents and standard laboratory equipment. It includes a 30-min lysis step, a 27-min DNA extraction using the Promega Maxwell(®) 16 System, DNA quantification in <1 h using the Qiagen Investigator(®) Quantiplex HYres kit, fast amplification (<26 min) of the loci included in AmpFℓSTR(®) Identifiler(®), and analysis of the profiles on the 3500-series Genetic Analyzer. This combination of fast individual steps produces high-quality profiling results and offers a cost-effective alternative approach to rapid DNA analysis. © 2015 American Academy of Forensic Sciences.

  16. In vitro and in vivo delivery of the secretagogue diadenosine tetraphosphate from conventional and silicone hydrogel soft contact lenses

    PubMed Central

    Dominguez-Godinez, Carmen Olalla; Martin-Gil, Alba; Carracedo, Gonzalo; Guzman-Aranguez, Ana; González-Méijome, José Manuel; Pintor, Jesús

    2013-01-01

    Purpose To evaluate the possible use of soft contact lenses (CL) to improve the secretagogue role of diadenosine tetraphosphate (Ap4A) promoting tear secretion. Methods Two conventional hydrogel CL (Omafilcon A and Ocufilcon D) and two silicone hydrogel (SiH) CL (Comfilcon A and Balafilcon A) were used. Ap4A was loaded into the lenses by soaking in a 1 mM Ap4A solution during 12 h. In vitro experiments were performed by placing the lenses in multi-wells during 2 h containing 1 ml of ultrapure water. 100 μl aliquots were taken at time zero and every minute for the first 10 min, and then every 15 min. In vivo experiments were performed in New Zealand rabbits and both the dinucleotide release from SiH and tear secretion were measured by means of Schirmer strips and high-pressure liquid chromatography (HPLC) analysis. Results Ap4A in vitro release experiments in hydrogel CL presented a release time 50 (RT50) of 3.9 ± 0.2 min and 3.1 ± 0.1 min for the non-ionic and the ionic CL, respectively. SiH CL released also Ap4A with RT50 values of 5.1 ± 0.1 min for the non-ionic and 2.7 ± 0.1 min for the ionic CL. In vivo experiments with SiH CL showed RT50 values of 9.3 ± 0.2 min and 8.5 ± 0.2 min for the non-ionic and the ionic respectively. The non-ionic lens Ap4A release was able to induce tear secretion above baseline tear levels for almost 360 min. Conclusion The delivery of Ap4A is slower and the effect lasts longer with non-ionic lenses than ionic lenses.

  17. Rapid and Sensitive Quantification of Ursolic Acid and Oleanolic Acid in Human Plasma Using Ultra-performance Liquid Chromatography-Mass Spectrometry.

    PubMed

    Stebounova, Larissa; Ebert, Scott M; Murry, Logan T; Adams, Christopher M; Murry, Daryl J

    2018-04-26

    Ultra-performance liquid chromatography (UPLC) interfaced with atmospheric pressure chemical ionization mass-spectrometry was used to separate and quantify ursolic acid (UA) and oleanolic acid (OA) in human plasma. UA and OA were extracted from 0.5 mL human plasma using supported liquid extraction and separated utilizing an Acquity UPLC HSS column. The method has been validated for both UA and OA quantitation with a limit of detection of 0.5 ng/mL. The UPLC separations are carried out with isocratic elution with methanol and 5 mM ammonium acetate in water (85:15) as a mobile phase at a flow rate of 0.4 mL/min. The assay was linear from 1 ng/mL to 100 ng/mL for both analytes. The total analysis time was 7 min with the retention times of 3.25 (internal standard), 3.65 (UA) and 3.85 min (OA). Recovery of drug from plasma ranged from 70% to 115%. Analysis of quality control samples at 3, 30 and 80 ng/mL (n = 14) had an intra-day coefficient of variation of 9.9%, 4.3% and 5.5%, respectively. A proof-of-concept study in human patients who consumed apple peels indicates that this analytical method could be applied to clinical studies of UA and/or OA in human subjects.

  18. Estimating the dim light melatonin onset of adolescents within a 6-h sampling window: the impact of sampling rate and threshold method

    PubMed Central

    Crowley, Stephanie J.; Suh, Christina; Molina, Thomas A.; Fogg, Louis F.; Sharkey, Katherine M.; Carskadon, Mary A.

    2016-01-01

    Objective/Background Circadian rhythm sleep-wake disorders often manifest during the adolescent years. Measurement of circadian phase such as the Dim Light Melatonin Onset (DLMO) improves diagnosis and treatment of these disorders, but financial and time costs limit the use of DLMO phase assessments in clinic. The current analysis aims to inform a cost-effective and efficient protocol to measure the DLMO in older adolescents by reducing the number of samples and total sampling duration. Patients/Methods A total of 66 healthy adolescents (26 males) aged 14.8 to 17.8 years participated in a study in which sleep was fixed for one week before they came to the laboratory for saliva collection in dim light (<20 lux). Two partial 6-h salivary melatonin profiles were derived for each participant. Both profiles began 5 h before bedtime and ended 1 h after bedtime, but one profile was derived from samples taken every 30 mins (13 samples) and the other from samples taken every 60 mins (7 samples). Three standard thresholds (first 3 melatonin values mean + 2 SDs, 3 pg/mL, and 4 pg/mL) were used to compute the DLMO. Agreement between DLMOs derived from 30-min and 60-min sampling rates was determined using a Bland-Altman analysis; agreement between sampling rate DLMOs was defined as ± 1 h. Results and Conclusions Within a 6-h sampling window, 60-min sampling provided DLMO estimates that were within ± 1 h of DLMO from 30-min sampling, but only when an absolute threshold (3 pg/mL or 4 pg/mL) was used to compute the DLMO. Future analyses should be extended to include adolescents with circadian rhythm sleep-wake disorders. PMID:27318227

  19. Non-thermal plasma for inactivated-vaccine preparation.

    PubMed

    Wang, Guomin; Zhu, Ruihao; Yang, Licong; Wang, Kaile; Zhang, Qian; Su, Xia; Yang, Bing; Zhang, Jue; Fang, Jing

    2016-02-17

    Vaccines are of great importance in controlling the spread of infectious diseases in poultry farming. The safety and efficacy of vaccines are also essential. To explore the feasibility of a novel technology (non-thermal plasma) in inactivated vaccine preparation, an alternating current atmospheric pressure non-thermal plasma (NTP) jet with Ar/O2/N2 as the operating gas was used to inactivate a Newcastle disease virus (NDV, LaSota) strain and H9N2 avian influenza virus (AIV, A/Chicken/Hebei/WD/98) for vaccine preparation. The results showed that complete inactivation could be achieved with 2 min of NTP treatment for both NDV and AIV. Moreover, a proper NTP treatment time is needed for inactivation of a virus without destruction of the antigenic determinants. Compared to traditional formaldehyde-inactivated vaccine, the vaccine made from NDV treated by NTP for 2 min (NTP-2 min-NDV-vaccine) could induce a higher NDV-specific antibody titer in specific pathogen-free (SPF) chickens, and the results of a chicken challenge experiment showed that NTP-2 min-NDV-vaccine could protect SPF chickens from a lethal NDV challenge. Vaccines made from AIV treated by NTP for 2 min (NTP-2 min-AIV-vaccine) also showed a similar AIV-specific antibody titer compared with traditional AIV vaccines prepared using formaldehyde inactivation. Studies of the morphological changes of the virus, chemical analysis of NDV allantoic fluid and optical emission spectrum analysis of NTP suggested that reactive oxygen species and reactive nitrogen species produced by NTP played an important role in the virus inactivation process. All of these results demonstrated that it could be feasible to use non-thermal NTP as an alternative strategy to prepare inactivated vaccines for Newcastle disease and avian influenza. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Pharmacokinetics of lidocaine and its metabolite in peridural anesthesia administered to pregnant women with gestational diabetes mellitus.

    PubMed

    Moisés, Elaine Christine Dantas; Duarte, Luciana de Barros; Cavalli, Ricardo de Carvalho; Marques, Maria Paula; Lanchote, Vera Lúcia; Duarte, Geraldo; da Cunha, Sérgio Pereira

    2008-12-01

    Peridural blockade with lidocaine, bupivacaine, and fentanyl is an anesthetic procedure extensively used in obstetrics, justifying the pharmacokinetic study of these drugs during labor. To investigate the influence of the physiopathological changes of gestational diabetes mellitus (GDM) on the pharmacokinetics of lidocaine and its metabolite monoethylglycinexylidide (MEGX) in pregnant women subjected to peridural anesthesia. Ten normal pregnant women (group 1) and six pregnant women with GDM (group 2) were studied, all of them at term. The patients received 200 mg 2% lidocaine hydrochloride without a vasoconstrictor by the peridural locoregional route. Maternal blood samples were collected at predetermined times for the analysis of lidocaine and MEGX by chromatography and pharmacokinetic analysis. The median pharmacokinetic parameters of lidocaine for groups 1 and 2 (P

  1. Impact of ultraviolet radiation treatments on the quality of freshly prepared tomato (Solanum lycopersicum) juice.

    PubMed

    Bhat, Rajeev

    2016-12-15

    Impact of ultraviolet (UV-C) radiation treatments (0, 15, 30 and 60min) on freshly extracted tomato juice quality (physicochemical properties, antioxidant activity and microbial load) was evaluated. On exposure to UV-C, level of water activity, total soluble solids, and titratable acidity exhibited non-significant increase up to 30min of exposure time. Regarding colour analysis, L∗ value significantly increased with subsequent decrease in a∗ and b∗ values post UV-C treatments. Clarity, DPPH (1,1-diphenyl-2-picrylhydrazyl) radical scavenging activity and total phenolics content significantly increased, whereas ascorbic acid level significantly reduced at 60min of UV-C exposure time. So also, lycopene content exhibited a non-significant decrease after UV-C treatment. Microbial studies showed reduction in total plate count and total mould counts post UV-C treatment. Overall, UV-C treatment being a physical, non-thermal method of food preservation holds the ability to improve or preserve vital quality parameters in freshly prepared tomato juices, and henceforth possesses high scope for commercial exploration. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Oil extraction from Scenedesmus obliquus using a continuous microwave system--design, optimization, and quality characterization.

    PubMed

    Balasubramanian, Sundar; Allen, James D; Kanitkar, Akanksha; Boldor, Dorin

    2011-02-01

    A 1.2 kW, 2450 MHz resonant continuous microwave processing system was designed and optimized for oil extraction from green algae (Scenedesmus obliquus). Algae-water suspension (1:1 w/w) was heated to 80 and 95°C, and subjected to extraction for up to 30 min. Maximum oil yield was achieved at 95°C and 30 min. The microwave system extracted 76-77% of total recoverable oil at 20-30 min and 95°C, compared to only 43-47% for water bath control. Extraction time and temperature had significant influence (p<0.0001) on extraction yield. Oil analysis indicated that microwaves extracted oil containing higher percentages of unsaturated and essential fatty acids (indicating higher quality). This study validates for the first time the efficiency of a continuous microwave system for extraction of lipids from algae. Higher oil yields, faster extraction rates and superior oil quality demonstrate this system's feasibility for oil extraction from a variety of feedstock. Copyright © 2010 Elsevier Ltd. All rights reserved.

  3. Treatment and technical intervention time analysis of a robotic stereotactic radiotherapy system.

    PubMed

    Crop, F; Lacornerie, T; Szymczak, H; Felin, A; Bailleux, C; Mirabel, X; Lartigau, E

    2014-02-01

    The purpose of this study is to obtain a better operational knowledge of Stereotactic Body Radiotherapy (SBRT) treatments with CyberKnife(r). An analysis of both In-room Times (IRT) and technical interventions of 5 years of treatments was performed, during which more than 1600 patients were treated for various indications, including liver (21%), lung (29%), intracranial (13%), head and neck (11%) and prostate (7%). Technical interventions were recorded along with the time of the failure, time to the intervention, and the complexity and duration of the repair. Analyses of Time Between Failures (TBF) and Service Disrupting TBF(disr) were performed. Treatment time data and variability per indication and following different system upgrades were evaluated. Large variations of IRTs were found between indications, but also large variations for each indication. The combination of the time reduction Tool (using Iris(r)) and Improved Stop Handling was of major impact to shortening of treatment times. The first implementation of the Iris collimator alone did not lead to significantly shorter IRTs for us except during prostate treatments. This was mostly due to the addition at the same time of larger rotational compensation for prostate treatments (58 instead of 1.58). Significant differences of duration between the first fraction and following fractions of a treatment, representing the necessity of defining imaging parameters and explanation to patients, were found for liver (12 min) and lung treatments using Xsight(r) Spine (5 min). Liver and lung treatments represent the longest IRT's and involve the largest variability's in IRT. The malfunction rate of the system followed a Weibull distribution with the shape and scale parameters of 0.8 and 39.7. Mean TBF(disr) was 68 work hours. 60 to 80% of the service disrupting interventions were resolved within 30-60 min, 5% required external intervention and 30% occurred in the morning. The presented results can be applied in the evaluation of the required machine time in order to implement robotic radiosurgery for different indications. The analytical distributions of IRTs and technical interruptions can be used for simulations.

  4. The Effect of Lipid Emulsion on Pharmacokinetics of Bupivacaine in Rats: Long-Chain Triglyceride Versus Long- and Medium-Chain Triglyceride.

    PubMed

    Tang, Wan; Wang, Quanguang; Shi, Kejian; Dong, Jiaojiao; Lin, Shengxian; Zhao, Shishi; Wu, Cong; Xia, Yun; Papadimos, Thomas J; Xu, Xuzhong

    2016-11-01

    Lipid infusions have been proposed to treat local anesthetic-induced cardiac toxicity. This study compared the effects of long-chain triglyceride (LCT) emulsions with those of long- and medium-chain triglyceride (LCT/MCT) emulsions on the pharmacokinetics of bupivacaine in a rat model. After administration of intravenous infusion of bupivacaine at 2 mg·kg·min for 5 minutes in Sprague-Dawley (SD) rats, either Intralipid 20%, an LCT emulsion (LCT group, n = 6), or Lipovenoes 20%, an LCT/MCT emulsion (LCT/MCT group, n = 6), was infused at 2mg·kg·min for 5 minutes. The concentrations of total plasma bupivacaine and bupivacaine that were not bound by lipid (lipid unbound) were measured by a liquid chromatography-tandem mass spectrometric method. A 2-compartmental analysis was performed to calculate the lipid-bound percentage of bupivacaine and its pharmacokinetics. In the LCT group, the clearance (15 ± 2 vs 10 ± 1 mL·min·kg, P = .003) was higher; the volume of distribution (0.57 ± 0.10 vs 0.36 ± 0.11 L·kg, P = .007) and K21 (0.0100 ± 0.0018 vs 0.0070 ± 0.0020 min, P = .021, P' = .032) were larger; and the area under the blood concentration-time curve 0 - t; (605 ± 82 vs 867 ± 110 mgL·min, P =.001) and the area under the blood concentration-time curve (0 - ∞) (697 ± 111 vs 991 ± 121 mgL·min, P =.001) were less, when compared with the LCT/MCT group. LCT emulsions are more effective than LCT/MCT emulsions in the metabolism of bupivacaine through demonstration of a superior pharmacokinetic profile.

  5. Effect of processing conditions on oil point pressure of moringa oleifera seed.

    PubMed

    Aviara, N A; Musa, W B; Owolarafe, O K; Ogunsina, B S; Oluwole, F A

    2015-07-01

    Seed oil expression is an important economic venture in rural Nigeria. The traditional techniques of carrying out the operation is not only energy sapping and time consuming but also wasteful. In order to reduce the tedium involved in the expression of oil from moringa oleifera seed and develop efficient equipment for carrying out the operation, the oil point pressure of the seed was determined under different processing conditions using a laboratory press. The processing conditions employed were moisture content (4.78, 6.00, 8.00 and 10.00 % wet basis), heating temperature (50, 70, 85 and 100 °C) and heating time (15, 20, 25 and 30 min). Results showed that the oil point pressure increased with increase in seed moisture content, but decreased with increase in heating temperature and heating time within the above ranges. Highest oil point pressure value of 1.1239 MPa was obtained at the processing conditions of 10.00 % moisture content, 50 °C heating temperature and 15 min heating time. The lowest oil point pressure obtained was 0.3164 MPa and it occurred at the moisture content of 4.78 %, heating temperature of 100 °C and heating time of 30 min. Analysis of Variance (ANOVA) showed that all the processing variables and their interactions had significant effect on the oil point pressure of moringa oleifera seed at 1 % level of significance. This was further demonstrated using Response Surface Methodology (RSM). Tukey's test and Duncan's Multiple Range Analysis successfully separated the means and a multiple regression equation was used to express the relationship existing between the oil point pressure of moringa oleifera seed and its moisture content, processing temperature, heating time and their interactions. The model yielded coefficients that enabled the oil point pressure of the seed to be predicted with very high coefficient of determination.

  6. Isocapnic hyperventilation shortens washout time for sevoflurane - an experimental in vivo study.

    PubMed

    Hallén, K; Stenqvist, O; Ricksten, S-E; Lindgren, S

    2016-10-01

    Isocapnic hyperventilation (IHV) is a method that fastens weaning from inhalation anaesthesia by increasing airway concentration of carbon dioxide (CO2 ) during hyperventilation (HV). In an animal model, we evaluated a technique of adding CO2 directly to the breathing circuit of a standard anaesthesia apparatus. Eight anaesthetised pigs weighing 28 ± 2 kg were intubated and mechanically ventilated. From a baseline ventilation of 5 l/min, HV was achieved by doubling minute volume and fresh gas flow. Respiratory rate was increased from 15 to 22/min. The CO2 absorber was disconnected and CO2 was delivered (DCO2 ) to the inspiratory limb of a standard breathing circuit via a mixing box. Time required to decrease end-tidal sevoflurane concentration from 2.7% to 0.2% was defined as washout time. Respiration and haemodynamics were monitored by blood gas analysis, spirometry, electric impedance tomography and pulse contour analysis. A DCO2 of 261 ± 19 ml/min was necessary to achieve isocapnia during HV. The corresponding FICO2 -level remained stable at 3.1 ± 0.3%. During IHV, washout of sevoflurane was three times faster, 433 ± 135 s vs. 1387 ± 204 s (P < 0.001). Arterial CO2 tension and end-tidal CO2 , was 5.2 ± 0.4 kPa and 5.6 ± 0.4%, respectively, before IHV and 5.1 ± 0.3 kPa and 5.7 ± 0.3%, respectively, during IHV. In this experimental in vivo model of isocapnic hyperventilation, the washout time of sevoflurane anaesthesia was one-third compared to normal ventilation. The method for isocapnic hyperventilation described can potentially be transferred to a clinical setting with the intention to decrease emergence time from inhalation anaesthesia. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  7. Re-engineering Ammunition Residue Management in IMCOM-SE

    DTIC Science & Technology

    2008-06-01

    Max Accoutability ) Non-Automatic Return Item Recycling (OBJ: Max Items, Max Profit) Regionalize Store Brass (OBJ: Min Time) Demilitarize... Accoutability ) Non-Automatic Return Item Recycling (OBJ: Max Items, Max Profit) Regionalize Store Brass (OBJ: Min Time) Demilitarize Brass (OBJ: Min

  8. Tolerance of brown bear spermatozoa to conditions of pre-freezing cooling rate and equilibration time.

    PubMed

    López-Urueña, E; Alvarez, M; Gomes-Alves, S; Martínez-Rodríguez, C; Borragan, S; Anel-López, L; de Paz, P; Anel, L

    2014-06-01

    Specific protocols for the cryopreservation of endangered Cantabrian brown bear spermatozoa are critical to create a genetic resource bank. The aim of this study was to assess the effect of cooling rates and equilibration time before freezing on post-thawed brown bear spermatozoa quality. Electroejaculates from 11 mature bears were extended to 100 × 10(6) spermatozoa/mL in a TES-Tris-Fructose-based extender, cryopreserved following performance of the respective cooling/equilibration protocol each sample was assigned to, and stored at -196 °C for further assessment. Before freezing, after thawing, and after 1 hour's incubation post-thawing at 37 °C (thermal stress test), the quality of the samples was assessed for motility by computer-assisted semen analysis, and for viability (SYBR-14/propidium iodide), acrosomal status (peanut agglutinin-fluorescein isothiocyanate /propidium iodide), and sperm chromatin stability (SCSA) by flow cytometry. In experiment 1, three cooling rates (0.25 °C/min, 1 °C/min, and 4 °C/min) to 5 °C were assessed. After thawing, total motility (%TM) was higher and percentage of damaged acrosomes (%dACR) was lower (P < 0.05) for 0.25 °C/min than for 4 °C/min. The thermal stress test data indicated equally poor quality (P < 0.05) for the 4 °C/min cooled samples in viability (%VIAB), %dACR, %TM, and progressive motility (%PM). In experiment 2, the effect of a pre-freezing equilibration period at 5 °C for 1 hour (cooling at 0.25 °C/min) was evaluated. Samples kept at 5 °C for 1 hour showed higher (P < 0.05) values than the nonequilibrated ones for both thawing (%dACR) and thermal stress test (%VIAB, %TM, and %PM). In experiment 3, samples stored without cooling and equilibration (direct freezing) were compared with the samples cooled at 0.25 °C/min and equilibrated for 1 hour (control freezing). Using thermal stress test, we observed that direct freezing causes damage in viability, acrosomal status, and motility of spermatozoa compared with the control group (P < 0.05). In conclusion, our results suggest that slow cooling rates to 5 °C and at least 1 hour equilibration time are necessary for the effective cryopreservation of brown bear sperm. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Relationships between older adults' use of time and cardio-respiratory fitness, obesity and cardio-metabolic risk: A compositional isotemporal substitution analysis.

    PubMed

    Dumuid, D; Lewis, L K; Olds, T S; Maher, C; Bondarenko, C; Norton, L

    2018-04-01

    Older adults' health has been linked with time in moderate-to-vigorous physical activity (MVPA), and recent studies suggest time in sedentary behaviour may also be important. Time-use behaviours (MVPA, light physical activity, sedentary time and sleep) are co-dependent, and therefore their associations with health should be examined in an integrated manner. This is the first study to investigate the relationship between older adults' reallocation of time among these time-use behaviours and markers of cardio-respiratory fitness, obesity and cardio-metabolic risk. Cross-sectional study of 122 Australians (65 ± 3 y, 61% female). Daily time use: average daily minutes spent in MVPA, light physical activity, sedentary time and sleep derived from 24-h, 7-day accelerometry, were conceptualised as a time-use composition. Cardio-respiratory fitness: graded submaximal cycle ergometer test. Obesity: objectively measured body mass index (BMI) and waist-to-hip ratio (WHR). Cardio-metabolic risk: sphygmomanometer-measured resting blood pressure and fingertip blood sampling for fasting total cholesterol and glucose. Time-use composition was significantly associated with obesity markers (BMI, p = 0.001; WHR, p < 0.001). The reallocation of 15 min to MVPA from any of the other behaviours was associated with approximately +1.1 (95% confidence interval 0.2; 1.9) ml/kg -1  min -1 VO 2max , -0.7 (-1.0; -0.3) BMI units and -1.2 (-1.8; -0.7) WHR percentage points, while the opposite reallocation (15 min from MVPA to other behaviours) was associated with larger difference estimates of -1.8 (-3.2; -0.4) ml/kg -1  min -1 VO 2max , +1.2 (0.5; 1.9) BMI units and +2.1 (1.2; 3.1) WHR percentage points. These findings reinforce the importance of MVPA for health among older adults. Interventions to maintain MVPA, even without increasing it, may be valuable. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. National youth sedentary behavior and physical activity daily patterns using latent class analysis applied to accelerometry.

    PubMed

    Evenson, Kelly R; Wen, Fang; Hales, Derek; Herring, Amy H

    2016-05-03

    Applying latent class analysis (LCA) to accelerometry can help elucidated underlying patterns. This study described the patterns of accelerometer-determined sedentary behavior and physical activity among youth by applying LCA to a nationally representative United States (US) sample. Using 2003-2006 National Health and Nutrition Examination Survey data, 3998 youths 6-17 years wore an ActiGraph 7164 accelerometer for one week, providing > =3 days of wear for > =8 h/day from 6:00 am-midnight. Cutpoints defined sedentary behavior (<100 counts/minute), light activity (100-2295 counts/minute), moderate to vigorous physical activity (MVPA; > = 2296 counts/minute), and vigorous activity (> = 4012 counts/minute). To account for wear time differences, outcomes were expressed as percent of day in a given intensity. LCA was used to classify daily (Monday through Sunday) patterns of average counts/minute, sedentary behavior, light activity, MVPA, and vigorous activity separately. The latent classes were explored overall and by age (6-11, 12-14, 15-17 years), gender, and whether or not youth attended school during measurement. Estimates were weighted to account for the sampling frame. For average counts/minute/day, four classes emerged from least to most active: 40.9% of population (mean 323.5 counts/minute/day), 40.3% (559.6 counts/minute/day), 16.5% (810.0 counts/minute/day), and 2.3% (1132.9 counts/minute/day). For percent of sedentary behavior, four classes emerged: 13.5% of population (mean 544.6 min/day), 30.1% (455.1 min/day), 38.5% (357.7 min/day), and 18.0% (259.2 min/day). For percent of light activity, four classes emerged: 12.3% of population (mean 222.6 min/day), 29.3% (301.7 min/day), 41.8% (384.0 min/day), and 16.6% (455.5 min/day). For percent of MVPA, four classes emerged: 59.9% of population (mean 25.0 min/day), 33.3% (60.9 min/day), 3.1% (89.0 min/day), and 3.6% (109.3 min/day). For percent of vigorous activity, three classes emerged: 76.8% of population (mean 7.1 min/day), 18.5% (23.9 min/day), and 4.7% (47.4 min/day). Classes were developed by age, gender, and school attendance since some patterns differed when stratifying by these factors. The models supported patterns for average intensity, sedentary behavior, light activity, MVPA, and vigorous activity. These latent class derived patterns can be used in other youth studies to explore correlates or outcomes and to target sedentary behavior or physical activity interventions.

  11. Measurement of citrate in urine using liquid chromatography tandem mass spectrometry: comparison with an enzymatic method.

    PubMed

    Keevil, B G; Owen, L; Thornton, S; Kavanagh, J

    2005-09-01

    Measurement of urine citrate is used to assess the risk of further urinary stone formation and to assess the benefit of treatment in affected individuals. We wanted to develop a simple and rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the analysis of urinary citrate and to compare it with our current enzymatic assay. For the LC-MS/MS assay, samples were prepared in a deep-well block by adding 10 microL of urine and 20 microL of internal standard to 400 microL of water. After mixing, 3 microL of the diluted sample was injected into the LC-MS/MS system. An LC system was used to isocratically elute a C18 column (50 x 2.1 mm) with 0.4 mL/min water containing 2 mmol/L ammonium acetate and 0.1% (v/v) formic acid. A step gradient of 100% methanol containing 2 mmol/L ammonium acetate and 0.1% (v/v) formic acid was used to wash the column. The retention times were 1.4 min for citrate and 1.4 min for d4-citrate. Cycle time was 4.0 min, injection to injection. The analytes were monitored using a tandem mass spectrometer operated in multiple reaction monitoring mode using the following transitions, citrate m/z 191.0>111.0 and d4-citrate m/z 195.0>113.0. Within and between-batch coefficients of variation were <3% over the range 480-3800 micromol/L. The lower limit of quantification was 24.0 micromol/L. Regression analysis showed LC-MS/MS = 0.8781 (enzymatic assay) + 102.5, r = 0.964, n = 73. We have developed a simple LC-MS/MS method for urinary citrate measurement that shows acceptable performance.

  12. Enhanced charge transport and photovoltaic performance of PBDTTT-C-T/PC70BM solar cells via UV-ozone treatment.

    PubMed

    Adhikary, Prajwal; Venkatesan, Swaminathan; Adhikari, Nirmal; Maharjan, Purna P; Adebanjo, Olusegun; Chen, Jihua; Qiao, Qiquan

    2013-10-21

    In this work, the electron transport layer of PBDTTT-C-T/PC70BM polymer solar cells were subjected to UV-ozone treatment, leading to improved cell performances from 6.46% to 8.34%. The solar cell efficiency reached a maximum of 8.34% after an optimal 5 minute UV-ozone treatment, and then decreased if treated for a longer time. To the best of our knowledge, the mechanism behind the effects of UV-ozone treatment on the improvement of charge transport and cell performance is not fully understood. We have developed a fundamental understanding of the UV-ozone treatment mechanism, which explains both the enhancements in charge transport and photovoltaic performance at an optimal treatment time, and also the phenomenon whereby further treatment time leads to a drop in cell efficiency. Transient photocurrent measurements indicated that the cell charge transport times were 1370 ns, 770 ns, 832 ns, 867 ns, and 1150 ns for the 0 min, 5 min, 10 min, 15 min, and 20 min UV-ozone treatment times, respectively. Therefore the 5 min UV-ozone treatment time led to the shortest transport time and the most efficient charge transport in the cells. The 5 min UV-ozone treated sample exhibited the highest peak intensity (E2) in the Raman spectra of the treated films, at about 437 cm(-1), indicating that it possessed the best wurtzite phase crystallinity of the ZnO films. Further increasing the UV-ozone treatment time from 5 to 20 min induced the formation of p-type defects (e.g. interstitial oxygen atoms), pushing the ZnO Fermi-level further away from the vacuum level, and decreasing the wurtzite crystallinity.

  13. Novel rechargeable calcium phosphate nanoparticle-containing orthodontic cement.

    PubMed

    Xie, Xian-Ju; Xing, Dan; Wang, Lin; Zhou, Han; Weir, Michael D; Bai, Yu-Xing; Xu, Hockin Hk

    2017-03-01

    White spot lesions (WSLs), due to enamel demineralization, occur frequently in orthodontic treatment. We recently developed a novel rechargeable dental composite containing nanoparticles of amorphous calcium phosphate (NACP) with long-term calcium (Ca) and phosphate (P) ion release and caries-inhibiting capability. The objectives of this study were to develop the first NACP-rechargeable orthodontic cement and investigate the effects of recharge duration and frequency on the efficacy of ion re-release. The rechargeable cement consisted of pyromellitic glycerol dimethacrylate (PMGDM) and ethoxylated bisphenol A dimethacrylate (EBPADMA). NACP was mixed into the resin at 40% by mass. Specimens were tested for orthodontic bracket shear bond strength (SBS) to enamel, Ca and P ion initial release, recharge and re-release. The new orthodontic cement exhibited an SBS similar to commercial orthodontic cement without CaP release (P>0.1). Specimens after one recharge treatment (e.g., 1 min immersion in recharge solution repeating three times in one day, referred to as "1 min 3 times") exhibited a substantial and continuous re-release of Ca and P ions for 14 days without further recharge. The ion re-release did not decrease with increasing the number of recharge/re-release cycles (P>0.1). The ion re-release concentrations at 14 days versus various recharge treatments were as follows: 1 min 3 times>3 min 2 times>1 min 2 times>6 min 1 time>3 min 1 time>1 min 1 time. In conclusion, although previous studies have shown that NACP nanocomposite remineralized tooth lesions and inhibited caries, the present study developed the first orthodontic cement with Ca and P ion recharge and long-term release capability. This NACP-rechargeable orthodontic cement is a promising therapy to inhibit enamel demineralization and WSLs around orthodontic brackets.

  14. Inter-ictal spike detection using a database of smart templates.

    PubMed

    Lodder, Shaun S; Askamp, Jessica; van Putten, Michel J A M

    2013-12-01

    Visual analysis of EEG is time consuming and suffers from inter-observer variability. Assisted automated analysis helps by summarizing key aspects for the reviewer and providing consistent feedback. Our objective is to design an accurate and robust system for the detection of inter-ictal epileptiform discharges (IEDs) in scalp EEG. IED Templates are extracted from the raw data of an EEG training set. By construction, the templates are given the ability to learn by searching for other IEDs within the training set using a time-shifted correlation. True and false detections are remembered and classifiers are trained for improving future predictions. During detection, trained templates search for IEDs in the new EEG. Overlapping detections from all templates are grouped and form one IED. Certainty values are added based on the reliability of the templates involved. For evaluation, 2160 templates were used on an evaluation dataset of 15 continuous recordings containing 241 IEDs (0.79/min). Sensitivities up to 0.99 (7.24fp/min) were reached. To reduce false detections, higher certainty thresholds led to a mean sensitivity of 0.90 with 2.36fp/min. By using many templates, this technique is less vulnerable to variations in spike morphology. A certainty value for each detection allows the system to present findings in a more efficient manner and simplifies the review process. Automated spike detection can assist in visual interpretation of the EEG which may lead to faster review times. Copyright © 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  15. The Cost of Increasing Physical Activity and Maintaining Weight for Mid-Life Sedentary African American Women

    PubMed Central

    Johnson, Tricia; Schoeny, Michael; Fogg, Louis; Wilbur, JoEllen

    2015-01-01

    Objective To evaluate the marginal costs of increasing physical activity and maintaining weight for a lifestyle physical activity program targeting sedentary African American women. Methods Outcomes included change in minutes of total moderate to vigorous physical activity, leisure time moderate to vigorous physical activity and walking per week, and weight stability between baseline and maintenance at 48 weeks. Marginal cost effectiveness ratios (MCERs) were calculated for each outcome, and 95% confidence intervals were computed using a bootstrap method. The analysis was from the societal perspective and calculated in 2013 US dollars. Results For the 260 participants in the analysis, program costs were $165 ± 19, and participant costs were $164 ± 35, for a total cost of $329 ± 49. The MCER for change in walking was $1.50/min/wk (95% CI: 1.28, 1.87), $1.73/min/wk (95% CI: 1.41, 2.18) for change in moderate to vigorous physical activity, and $1.94/min/wk (95% CI: 1.58, 2.40) for leisure-time moderate to vigorous physical activity. The MCER for weight stability was $412 (95% CI: 399, 456). Discussion The Women's Lifestyle Physical Activity Program is a relatively low cost strategy for increasing physical activity. The marginal cost of increasing physical activity is lower than for weight stability. The participant costs related to time in the program were nearly half of the total costs, suggesting that practitioners and policy-makers should consider the participant cost when disseminating a lifestyle physical activity program into practice. PMID:26797232

  16. Tortuous iliac systems--a significant burden to conventional cannulation in the visceral segment: is there a role for robotic catheter technology?

    PubMed

    Riga, Celia V; Bicknell, Colin D; Hamady, Mohamad; Cheshire, Nicholas

    2012-10-01

    To attempt to quantify the effect of varying degrees of iliac tortuosity on maneuverability and "torquability" of endovascular catheters in the visceral segment, comparing conventional and robotic cannulation techniques. In a fenestrated endograft within a pulsatile phantom, 10 experienced operators cannulated the renal arteries via three different access vessels of varying iliac tortuosity with the use of conventional and robotic techniques. All procedures were performed in the angiography suite and recorded for blinded video assessment for quantitative (time, catheter-tip movements) and qualitative metrics (operator performance scores). In total, 120 cannulations were observed. With increasing iliac tortuosity, median time and number of catheter movements required for renal cannulation with conventional techniques increased in stepwise fashion for mild, moderate, and severe iliac tortuosity (times, 7.6 min [interquartile range (IQR), 4.6-9.3 min] vs 6.9 min [4.2-11.4 min] vs 17.7 min [13.3-22.6 min], respectively; movements, 184 [IQR, 110-351] vs 251 [207-395] vs 569 [409-616], respectively). Median renal cannulation times were significantly reduced with the use of the robotic system irrespective of mild, moderate, or severe tortuosity (times, 1.4 min [IQR, 1.1-1.9 min] vs 3 min [2.3-3.3 min] vs 2.8 min [1.5-3.9 min], respectively; movements, 19 [IQR, 14-27] vs 46 [43-58] vs 45 [40-66], respectively; P < .005). Overall operator performance scores improved significantly with the use of the robotic system irrespective of iliac tortuosity severity. In cases of moderate to severe iliac tortuosity, conventional catheter manipulation and control becomes an issue. The improvement in positional control and predictability seen with advanced catheter designs may be amplified in cases of severe iliac tortuosity. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  17. Sedentary behaviour patterns and carotid intima-media thickness in Spanish healthy adult population.

    PubMed

    García-Hermoso, Antonio; Martínez-Vizcaíno, Vicente; Recio-Rodríguez, José Ignacio; Sánchez-López, Mairena; Gómez-Marcos, Manuel Ángel; García-Ortiz, Luis

    2015-04-01

    The aim of this study was to analyze the association between sedentary behaviour, as assessed by an accelerometer, and mean carotid intima-media thickness (IMT). The study included 263 healthy subjects belonging to the EVIDENT study (59.3% women). Carotid IMT was measured by carotid ultrasonography. Sedentary behaviour was measured objectively over 7 days using ActiGraph accelerometers. Thresholds of 10 consecutive minutes were used to establish sedentary bouts, and assess the number (n/day), and length ≥10 min (min/day). Total sedentary time and sedentary time in bouts ≥10 min was higher in participants with a larger mean carotid IMT (>P75). Otherwise, this sedentary time in bouts ≥10 min parameter was weakly associated with augmented carotid IMT injury in the logistic regression model. Total sedentary time and sedentary time in bouts ≥10 min, as assessed by accelerometer, was positively but weakly associated with carotid IMT. Equally, this sedentary time in bouts ≥10 min was associated with carotid injury, but disappears after adjusting for potential confounders. These findings support that reducing sedentary time and increasing breaks in bouts of sedentary time might represent a useful additional strategy in the cardiovascular disease prevention. Clinical Trials.gov Identifier: NCT01083082. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. Biofuel from jute stick by pyrolysis technology

    NASA Astrophysics Data System (ADS)

    Ferdous, J.; Parveen, M.; Islam, M. R.; Haniu, H.; Takai, K.

    2017-06-01

    In this study the conversion of jute stick into biofuels and chemicals by externally heated fixed-bed pyrolysis reactor have been taken into consideration. The solid jute stick was characterized through proximate and ultimate analysis, gross calorific values and thermo-gravimetric analysis to investigate their suitability as feedstock for this consideration. The solid biomass particles were fed into the reactor by gravity feed type reactor feeder. The products were oil, char and gases. The liquid and char products were collected separately while the gas was flared into the atmosphere. The process conditions were varied by fixed-bed temperature; feed stock particle size, N2 gas flow rate and running time. All parameters were found to influence the product yields significantly. The maximum liquid yields were 50 wt% of solid jute stick at reactor temperature 425°C for N2 gas flow rate 6 l/min, feed particle size 1180-1700 µm and running time 30 min. Liquid products obtained at these conditions were characterized by physical properties, chemical analysis and GC-MS techniques. The results show that it is possible to obtained liquid products that are comparable to petroleum fuels and valuable chemical feedstock from the selected biomass if the pyrolysis conditions are chosen accordingly.

  19. DSC, X-ray and FTIR studies of a gemfibrozil/dimethyl-β-cyclodextrin inclusion complex produced by co-grinding.

    PubMed

    Aigner, Z; Berkesi, O; Farkas, G; Szabó-Révész, P

    2012-01-05

    The steps of formation of an inclusion complex produced by the co-grinding of gemfibrozil and dimethyl-β-cyclodextrin were investigated by differential scanning calorimetry (DSC), X-ray powder diffractometry (XRPD) and Fourier transform infrared (FTIR) spectroscopy with curve-fitting analysis. The endothermic peak at 59.25°C reflecting the melting of gemfibrozil progressively disappeared from the DSC curves of the products on increase of the duration of co-grinding. The crystallinity of the samples too gradually decreased, and after 35min of co-grinding the product was totally amorphous. Up to this co-grinding time, XRPD and FTIR investigations indicated a linear correlation between the cyclodextrin complexation and the co-grinding time. After co-grinding for 30min, the ratio of complex formation did not increase. These studies demonstrated that co-grinding is a suitable method for the complexation of gemfibrozil with dimethyl-β-cyclodextrin. XRPD analysis revealed the amorphous state of the gemfibrozil-dimethyl-β-cyclodextrin product. FTIR spectroscopy with curve-fitting analysis may be useful as a semiquantitative analytical method for discriminating the molecular and amorphous states of gemfibrozil. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. 'Stroke Room': Diagnosis and Treatment at a Single Location for Rapid Intraarterial Stroke Treatment.

    PubMed

    Ragoschke-Schumm, Andreas; Yilmaz, Umut; Kostopoulos, Panagiotis; Lesmeister, Martin; Manitz, Matthias; Walter, Silke; Helwig, Stefan; Schwindling, Lenka; Fousse, Mathias; Haass, Anton; Garner, Dominique; Körner, Heiko; Roumia, Safwan; Grunwald, Iris; Nasreldein, Ali; Halmer, Ramona; Liu, Yang; Schlechtriemen, Thomas; Reith, Wolfgang; Fassbender, Klaus

    2015-01-01

    For patients with acute ischemic stroke, intra-arterial treatment (IAT) is considered to be an effective strategy for removing the obstructing clot. Because outcome crucially depends on time to treatment ('time-is-brain' concept), we assessed the effects of an intervention based on performing all the time-sensitive diagnostic and therapeutic procedures at a single location on the delay before intra-arterial stroke treatment. Consecutive acute stroke patients with large vessel occlusion who obtained IAT were evaluated before and after implementation (April 26, 2010) of an intervention focused on performing all the diagnostic and therapeutic measures at a single site ('stroke room'). After implementation of the intervention, the median intervals between admission and first angiography series were significantly shorter for 174 intervention patients (102 min, interquartile range (IQR) 85-120 min) than for 81 control patients (117 min, IQR 89-150 min; p < 0.05), as were the intervals between admission and clot removal or end of angiography (152 min, IQR 123-185 min vs. 190 min, IQR 163-227 min; p < 0.001). However, no significant differences in clinical outcome were observed. This study shows for the, to our knowledge, first time that for patients with acute ischemic stroke, stroke diagnosis and treatment at a single location ('stroke room') saves crucial time until IAT. © 2015 S. Karger AG, Basel.

Top