Riemannian and Lorentzian flow-cut theorems
NASA Astrophysics Data System (ADS)
Headrick, Matthew; Hubeny, Veronika E.
2018-05-01
We prove several geometric theorems using tools from the theory of convex optimization. In the Riemannian setting, we prove the max flow-min cut (MFMC) theorem for boundary regions, applied recently to develop a ‘bit-thread’ interpretation of holographic entanglement entropies. We also prove various properties of the max flow and min cut, including respective nesting properties. In the Lorentzian setting, we prove the analogous MFMC theorem, which states that the volume of a maximal slice equals the flux of a minimal flow, where a flow is defined as a divergenceless timelike vector field with norm at least 1. This theorem includes as a special case a continuum version of Dilworth’s theorem from the theory of partially ordered sets. We include a brief review of the necessary tools from the theory of convex optimization, in particular Lagrangian duality and convex relaxation.
Study of process parameter on mist lubrication of Titanium (Grade 5) alloy
NASA Astrophysics Data System (ADS)
Maity, Kalipada; Pradhan, Swastik
2017-02-01
This paper deals with the machinability of Ti-6Al-4V alloy with mist cooling lubrication using carbide inserts. The influence of process parameter on the cutting forces, evolution of tool wear, surface finish of the workpiece, material removal rate and chip reduction coefficient have been investigated. Weighted principal component analysis coupled with grey relational analysis optimization is applied to identify the optimum setting of the process parameter. Optimal condition of the process parameter was cutting speed at 160 m/min, feed at 0.16 mm/rev and depth of cut at 1.6 mm. Effects of cutting speed and depth of cut on the type of chips formation were observed. Most of the chips forms were long tubular and long helical type. Image analyses of the segmented chip were examined to study the shape and size of the saw tooth profile of serrated chips. It was found that by increasing cutting speed from 95 m/min to 160 m/min, the free surface lamella of the chips increased and the visibility of the saw tooth segment became clearer.
Multiple-objective optimization in precision laser cutting of different thermoplastics
NASA Astrophysics Data System (ADS)
Tamrin, K. F.; Nukman, Y.; Choudhury, I. A.; Shirley, S.
2015-04-01
Thermoplastics are increasingly being used in biomedical, automotive and electronics industries due to their excellent physical and chemical properties. Due to the localized and non-contact process, use of lasers for cutting could result in precise cut with small heat-affected zone (HAZ). Precision laser cutting involving various materials is important in high-volume manufacturing processes to minimize operational cost, error reduction and improve product quality. This study uses grey relational analysis to determine a single optimized set of cutting parameters for three different thermoplastics. The set of the optimized processing parameters is determined based on the highest relational grade and was found at low laser power (200 W), high cutting speed (0.4 m/min) and low compressed air pressure (2.5 bar). The result matches with the objective set in the present study. Analysis of variance (ANOVA) is then carried out to ascertain the relative influence of process parameters on the cutting characteristics. It was found that the laser power has dominant effect on HAZ for all thermoplastics.
Warnken, Tobias; Delarocque, Julien; Schumacher, Svenja; Huber, Korinna; Feige, Karsten
2018-01-19
Insulin dysregulation (ID) with basal or postprandial hyperinsulinemia is one of the key findings in horses and ponies suffering from the equine metabolic syndrome (EMS). Assessment of ID can easily be performed in clinical settings by the use of oral glucose challenge tests. Oral glucose test (OGT) performed with 1 g/kg bodyweight (BW) glucose administered via naso-gastric tube allows the exact administration of a defined glucose dosage in a short time. However, reliable cut-off values have not been available so far. Therefore, the aim of the study was to describe variations in insulin response to OGT via naso-gastric tubing and to provide a clinical useful cut-off value for ID when using the insulin quantification performed with an equine-optimized insulin enzyme-linked immunosorbent assay. Data visualization revealed no clear separation in the serum insulin concentration of insulin sensitive and insulin dysregulated horses during OGT. Therefore, a model based clustering method was used to circumvent the use of an arbitrary limit for categorization. This method considered all data-points for the classification, taking into account the individual insulin trajectory during the OGT. With this method two clusters were differentiated, one with low and one with high insulin responses during OGT. The cluster of individuals with low insulin response was consistently detected, independently of the initialization parameters of the algorithm. In this cluster the 97.5% quantile of insulin is 110 µLU/mL at 120 min. We suggest using this insulin concentration of 110 µLU/mL as a cut-off value for samples obtained at 120 min in OGT. OGT performed with 1 g/kg BW glucose and administration via naso-gastric tubing can easily be performed under clinical settings. Application of the cut-off value of 110 µLU/mL at 120 min allows assessment of ID in horses.
NASA Astrophysics Data System (ADS)
Cui, Shawn X.; Freedman, Michael H.; Sattath, Or; Stong, Richard; Minton, Greg
2016-06-01
The classical max-flow min-cut theorem describes transport through certain idealized classical networks. We consider the quantum analog for tensor networks. By associating an integral capacity to each edge and a tensor to each vertex in a flow network, we can also interpret it as a tensor network and, more specifically, as a linear map from the input space to the output space. The quantum max-flow is defined to be the maximal rank of this linear map over all choices of tensors. The quantum min-cut is defined to be the minimum product of the capacities of edges over all cuts of the tensor network. We show that unlike the classical case, the quantum max-flow=min-cut conjecture is not true in general. Under certain conditions, e.g., when the capacity on each edge is some power of a fixed integer, the quantum max-flow is proved to equal the quantum min-cut. However, concrete examples are also provided where the equality does not hold. We also found connections of quantum max-flow/min-cut with entropy of entanglement and the quantum satisfiability problem. We speculate that the phenomena revealed may be of interest both in spin systems in condensed matter and in quantum gravity.
Polynomial Supertree Methods Revisited
Brinkmeyer, Malte; Griebel, Thasso; Böcker, Sebastian
2011-01-01
Supertree methods allow to reconstruct large phylogenetic trees by combining smaller trees with overlapping leaf sets into one, more comprehensive supertree. The most commonly used supertree method, matrix representation with parsimony (MRP), produces accurate supertrees but is rather slow due to the underlying hard optimization problem. In this paper, we present an extensive simulation study comparing the performance of MRP and the polynomial supertree methods MinCut Supertree, Modified MinCut Supertree, Build-with-distances, PhySIC, PhySIC_IST, and super distance matrix. We consider both quality and resolution of the reconstructed supertrees. Our findings illustrate the tradeoff between accuracy and running time in supertree construction, as well as the pros and cons of voting- and veto-based supertree approaches. Based on our results, we make some general suggestions for supertree methods yet to come. PMID:22229028
The effect of cutting parameters on the performance of ZTA-MgO cutting tool
NASA Astrophysics Data System (ADS)
Ali, A. M.; Hamidon, N. E.; Zaki, N. K. M.; Mokhtar, S.; Azhar, A. Z. A.; Bahar, R.; Ahmad, Z. A.
2018-01-01
The effect of cutting parameters on the performances of ZTA-MgO ceramic cutting tool investigated. The aim of this project is to discover the effect of cutting speed and feedrate on the performance of the ZTA-MgO cutting tool via wear and surface roughness measurement. CNC turning machining performed using the cutting speed, Vc range from 354 to 471 m/min and the feed rate, f 0.1, 0.3 and 0.5 mm/rev while the depth of cut, d is kept constant at 0.2 mm. The flank wear, crater wear, and chipping were measured accordingly using optical microscope, Matlab programming and SEM. Surface roughness of machined stainless steel 316L surface were measured using the surface roughness tester (Mitutoyo MTR097-8. The result showing the increment trend of flank wear with increment of cutting speed and feed rate with the lowest value of flank wear, 0.061 mm achieved at Vc = 354 m/min and f = 0.1 mm/rev while the highest flank wear is 0.480 mm at Vc = 471 m/min and f = 0.5 mm/rev. The increasing pattern also observed in the crater wear results. The lowest area of crater wear is 2.2736 mm2 at Vc = 354 m/min and f = 0.1 mm/rev while the highest value is 4.8524 mm2 at Vc = 471 m/min and f = 0.5 mm/rev. As for the surface roughness, the higher the cutting speed, the lower the average roughness (Ra) value. Cutting speed, Vc = 471 m/min with f = 0.1 mm/rev has the lowest value of Ra which is 0.72µm.
Machining of bone: Analysis of cutting force and surface roughness by turning process.
Noordin, M Y; Jiawkok, N; Ndaruhadi, P Y M W; Kurniawan, D
2015-11-01
There are millions of orthopedic surgeries and dental implantation procedures performed every year globally. Most of them involve machining of bones and cartilage. However, theoretical and analytical study on bone machining is lagging behind its practice and implementation. This study views bone machining as a machining process with bovine bone as the workpiece material. Turning process which makes the basis of the actually used drilling process was experimented. The focus is on evaluating the effects of three machining parameters, that is, cutting speed, feed, and depth of cut, to machining responses, that is, cutting forces and surface roughness resulted by the turning process. Response surface methodology was used to quantify the relation between the machining parameters and the machining responses. The turning process was done at various cutting speeds (29-156 m/min), depths of cut (0.03 -0.37 mm), and feeds (0.023-0.11 mm/rev). Empirical models of the resulted cutting force and surface roughness as the functions of cutting speed, depth of cut, and feed were developed. Observation using the developed empirical models found that within the range of machining parameters evaluated, the most influential machining parameter to the cutting force is depth of cut, followed by feed and cutting speed. The lowest cutting force was obtained at the lowest cutting speed, lowest depth of cut, and highest feed setting. For surface roughness, feed is the most significant machining condition, followed by cutting speed, and with depth of cut showed no effect. The finest surface finish was obtained at the lowest cutting speed and feed setting. © IMechE 2015.
Hip and Wrist Accelerometer Algorithms for Free-Living Behavior Classification.
Ellis, Katherine; Kerr, Jacqueline; Godbole, Suneeta; Staudenmayer, John; Lanckriet, Gert
2016-05-01
Accelerometers are a valuable tool for objective measurement of physical activity (PA). Wrist-worn devices may improve compliance over standard hip placement, but more research is needed to evaluate their validity for measuring PA in free-living settings. Traditional cut-point methods for accelerometers can be inaccurate and need testing in free living with wrist-worn devices. In this study, we developed and tested the performance of machine learning (ML) algorithms for classifying PA types from both hip and wrist accelerometer data. Forty overweight or obese women (mean age = 55.2 ± 15.3 yr; BMI = 32.0 ± 3.7) wore two ActiGraph GT3X+ accelerometers (right hip, nondominant wrist; ActiGraph, Pensacola, FL) for seven free-living days. Wearable cameras captured ground truth activity labels. A classifier consisting of a random forest and hidden Markov model classified the accelerometer data into four activities (sitting, standing, walking/running, and riding in a vehicle). Free-living wrist and hip ML classifiers were compared with each other, with traditional accelerometer cut points, and with an algorithm developed in a laboratory setting. The ML classifier obtained average values of 89.4% and 84.6% balanced accuracy over the four activities using the hip and wrist accelerometer, respectively. In our data set with average values of 28.4 min of walking or running per day, the ML classifier predicted average values of 28.5 and 24.5 min of walking or running using the hip and wrist accelerometer, respectively. Intensity-based cut points and the laboratory algorithm significantly underestimated walking minutes. Our results demonstrate the superior performance of our PA-type classification algorithm, particularly in comparison with traditional cut points. Although the hip algorithm performed better, additional compliance achieved with wrist devices might justify using a slightly lower performing algorithm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cui, Shawn X., E-mail: xingshan@math.ucsb.edu; Quantum Architectures and Computation Group, Microsoft Research, Redmond, Washington 98052; Freedman, Michael H., E-mail: michaelf@microsoft.com
2016-06-15
The classical max-flow min-cut theorem describes transport through certain idealized classical networks. We consider the quantum analog for tensor networks. By associating an integral capacity to each edge and a tensor to each vertex in a flow network, we can also interpret it as a tensor network and, more specifically, as a linear map from the input space to the output space. The quantum max-flow is defined to be the maximal rank of this linear map over all choices of tensors. The quantum min-cut is defined to be the minimum product of the capacities of edges over all cuts ofmore » the tensor network. We show that unlike the classical case, the quantum max-flow=min-cut conjecture is not true in general. Under certain conditions, e.g., when the capacity on each edge is some power of a fixed integer, the quantum max-flow is proved to equal the quantum min-cut. However, concrete examples are also provided where the equality does not hold. We also found connections of quantum max-flow/min-cut with entropy of entanglement and the quantum satisfiability problem. We speculate that the phenomena revealed may be of interest both in spin systems in condensed matter and in quantum gravity.« less
NASA Astrophysics Data System (ADS)
Afolalu, S. A.; Okokpujie, I. P.; Salawu, E. Y.; Abioye, A. A.; Abioye, O. P.; Ikumapayi, O. M.
2018-04-01
The degree of holding temperature and time play a major role in nano-case treatment of cutting tools which immensely contributed to its performance during machining operation. The objective of this research work is to carryout comparative study of performance of nano-case treatment tools developed using low and medium carbon steel as work piece. Turning operation was carried out under two different categories with specific work piece on universal lathe machine using HSS cutting tools 100 mm × 12mm × 12mm that has been nano-case treated under varying conditions of temperatures and timeof 800,850, 900, 950°C and 60, 90, 120 mins respectively. The turning parameters used in evaluating this experiment were cutting speed of 270, 380 and 560mm/min, feed rate of 0.15, 0.20 and 0.25 mm/min, depth of cut of 2mm, work piece diameter of 25mm and rake angle of 7° each at three levels. The results of comparative study of their performances revealed that the timespent in the machining of low carbon steel material at a minimum temperature and time of 800°C, 60 mins were1.50, 2.17 mins while at maximum temperature and time of 950°C, 120 mins were 1.19, 2.02 mins. It was also observed that at a corresponding constant speed of 270,380 and 560mm/min at higher temperature and time, a relative increased in the length of cut were observed. Critical observation of the result showed that at higher case hardening temperature and time (950°C/120mins), the HSS cutting tool gave a better performance as lesser time was consumed during the turning operation.
Comparing cutting efficiencies of diamond burs using a high-speed electric handpiece.
Chung, Evelyn M; Sung, Eric C; Wu, Ben; Caputo, Angelo A
2006-01-01
This study sought to compare the cutting efficiency of different diamond burs on initial use as well as during repeated use, alternating with sterilization. Long, round-end, tapered diamond burs with similar diameter, profile, and diamond coarseness (125-150 microm grit) were used. A high-torque, high-speed electric handpiece (set at 200,000 rpm) was utilized with a coolant flow rate of 25 mL/min. Burs were tested under a constant load of 170 g while cuts were made on a machinable ceramic substrate block. Each bur was subjected to five consecutive cuts for 30 seconds of continuous operation and the cutting depths were measured. All burs performed similarly on the first cut. Cutting efficiencies for three of the bur groups decreased significantly after the first cycle; however, by the fifth cycle, all bur groups performed similarly without any significant differences (p > 0.05). A scanning electron microscope revealed significant crystal loss after each use.
Venkitanarayanan, K S; Ezeike, G O; Hung, Y C; Doyle, M P
1999-08-01
One milliliter of culture containing a five-strain mixture of Escherichia coli O157:H7 (approximately 10(10) CFU) was inoculated on a 100-cm2 area marked on unscarred cutting boards. Following inoculation, the boards were air-dried under a laminar flow hood for 1 h, immersed in 2 liters of electrolyzed oxidizing water or sterile deionized water at 23 degrees C or 35 degrees C for 10 or 20 min; 45 degrees C for 5 or 10 min; or 55 degrees C for 5 min. After each temperature-time combination, the surviving population of the pathogen on cutting boards and in soaking water was determined. Soaking of inoculated cutting boards in electrolyzed oxidizing water reduced E. coli O157:H7 populations by > or = 5.0 log CFU/100 cm2 on cutting boards. However, immersion of cutting boards in deionized water decreased the pathogen count only by 1.0 to 1.5 log CFU/100 cm2. Treatment of cutting boards inoculated with Listeria monocytogenes in electrolyzed oxidizing water at selected temperature-time combinations (23 degrees C for 20 min, 35 degrees C for 10 min, and 45 degrees C for 10 min) substantially reduced the populations of L. monocytogenes in comparison to the counts recovered from the boards immersed in deionized water. E. coli O157:H7 and L. monocytogenes were not detected in electrolyzed oxidizing water after soaking treatment, whereas the pathogens survived in the deionized water used for soaking the cutting boards. This study revealed that immersion of kitchen cutting boards in electrolyzed oxidizing water could be used as an effective method for inactivating foodborne pathogens on smooth, plastic cutting boards.
Pabiou, T; Fikse, W F; Amer, P R; Cromie, A R; Näsholm, A; Berry, D P
2012-09-01
The objective of this study was to quantify the genetic associations between a range of carcass-related traits including wholesale cut weights predicted from video image analysis (VIA) technology, and a range of pre-slaughter performance traits in commercial Irish cattle. Predicted carcass cut weights comprised of cut weights based on retail value: lower value cuts (LVC), medium value cuts (MVC), high value cuts (HVC) and very high value cuts (VHVC), as well as total meat, fat and bone weights. Four main sources of data were used in the genetic analyses: price data of live animals collected from livestock auctions, live-weight data and linear type collected from both commercial and pedigree farms as well as from livestock auctions and weanling quality recorded on-farm. Heritability of carcass cut weights ranged from 0.21 to 0.39. Genetic correlations between the cut traits and the other performance traits were estimated using a series of bivariate sire linear mixed models where carcass cut weights were phenotypically adjusted to a constant carcass weight. Strongest positive genetic correlations were obtained between predicted carcass cut weights and carcass value (min r g(MVC) = 0.35; max r(g(VHVC)) = 0.69), and animal price at both weaning (min r(g(MVC)) = 0.37; max r(g(VHVC)) = 0.66) and post weaning (min r(g(MVC)) = 0.50; max r(g(VHVC)) = 0.67). Moderate genetic correlations were obtained between carcass cut weights and calf price (min r g(HVC) = 0.34; max r g(LVC) = 0.45), weanling quality (min r(g(MVC)) = 0.12; max r (g(VHVC)) = 0.49), linear scores for muscularity at both weaning (hindquarter development: min r(g(MVC)) = -0.06; max r(g(VHVC)) = 0.46), post weaning (hindquarter development: min r(g(MVC)) = 0.23; max r(g(VHVC)) = 0.44). The genetic correlations between total meat weight were consistent with those observed with the predicted wholesale cut weights. Total fat and total bone weights were generally negatively correlated with carcass value, auction prices and weanling quality. Total bone weight was, however, positively correlated with skeletal scores at weaning and post weaning. These results indicate that some traits collected early in life are moderate-to-strongly correlated with carcass cut weights predicted from VIA technology. This information can be used to improve the accuracy of selection for carcass cut weights in national genetic evaluations.
The machined surface of magnesium AZ31 after rotary turning at air cooling condition
NASA Astrophysics Data System (ADS)
Akhyar, G.; Purnomo, B.; Hamni, A.; Harun, S.; Burhanuddin, Y.
2018-04-01
Magnesium is a lightweight metal that is widely used as an alternative to iron and steel. Magnesium has been applied in the automotive industry to reduce the weight of a component, but the machining process has the disadvantage that magnesium is highly flammable because it has a low flash point. High temperature can cause the cutting tool wear and contributes to the quality of the surface roughness. The purpose of this study is to obtain the value of surface roughness and implement methods of rotary cutting tool and air cooling output vortex tube cooler to minimize the surface roughness values. Machining parameters that is turning using rotary cutting tool at speed the workpiece of (Vw) 50, 120, 160 m/min, cutting speed of rotary tool of (Vt) 25, 50, 75 m/min, feed rate of (f) 0.1, 0.15, 0.2 mm/rev, and depth of cut of 0.3 mm. Type of tool used is a carbide tool diameter of 16 mm and air cooling pressure of 6 bar. The results show the average value of the lowest surface roughness on the speed the workpiece of 80 m/min, cutting speed of rotary tool of 50 m/min, feed rate of 0.2 mm/rev, and depth of cut of 0.3 mm. While the average value of the highest surface roughness on the speed the workpiece of 160 m/min, cutting speed of rotary tool of 50 m/min, feed rate of 0.2 mm/rev, and depth of cut of 0.3 mm. The influence of machining parameters concluded the higher the speed of the workpiece the surface roughness value higher. Otherwise the higher cutting speed of rotary tool then the lower the surface roughness value. The observation on the surface of the rotary tool, it was found that no uniform tool wear which causes non-uniform surface roughness. The use of rotary cutting tool contributing to lower surface roughness values generated.
Wright, Dannen D; Wright, Alex J; Boulter, Tyler D; Bernhisel, Ashlie A; Stagg, Brian C; Zaugg, Brian; Pettey, Jeff H; Ha, Larry; Ta, Brian T; Olson, Randall J
2017-09-01
To determine the optimum bottle height, vacuum, aspiration rate, and power settings in the peristaltic mode of the Whitestar Signature Pro machine with Ellips FX tip action (transversal). John A. Moran Eye Center Laboratories, University of Utah, Salt Lake City, Utah, USA. Experimental study. Porcine lens nuclei were hardened with formalin and cut into 2.0 mm cubes. Lens cubes were emulsified using transversal and fragment removal time (efficiency), and fragment bounces off the tip (chatter) were measured to determine optimum aspiration rate, bottle height, vacuum, and power settings in the peristaltic mode. Efficiency increased in a linear fashion with increasing bottle height and vacuum. The most efficient aspiration rate was 50 mL/min, with 60 mL/min statistically similar. Increasing power increased efficiency up to 90% with increased chatter at 100%. The most efficient values for the settings tested were bottle height at 100 cm, vacuum at 600 mm Hg, aspiration rate of 50 or 60 mL/min, and power at 90%. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Evaluation of Hard Coating Performance in Drilling Compacted Graphite Iron (CGI)
NASA Astrophysics Data System (ADS)
de Paiva, José M. F.; Amorim, Fred L.; Soares, P.; Torres, Ricardo D.
2013-10-01
The aim of this investigation was to compare the performance of the following commercial coatings system, TiAlN/TiN, AlCrN, and TiSiN/AlCrN, deposited in cemented carbide tools in drilling compact graphite iron (CGI). The drilling tests were conducted adopting two cutting speeds: 80 or 150 m/min. For each test condition, the tool flank wear, the machining feed force, and the circularity and the roughness of the resulting drilled hole were determined. At the cutting speed of 80 m/min, the results revealed that the tool life, in terms of flank wear, was improved for the Cr-based coatings, while the multilayered coatings presented a better performance at the cutting speed of 150 m/min. It was also found that feed force is substantially increased when drilling at a cutting speed of 150 m/min. The holes drilled with the TiSiN/AlCrN at a cutting speed of 150 m/min showed the best circularity. The drill roughness is directly influenced by the coating system wear and iron adhesion. Consequently, it was found that the lowest holes' roughness was obtained with TiSiN/AlCrN at 80 m/min.
Tool wear analysis during duplex stainless steel trochoidal milling
NASA Astrophysics Data System (ADS)
Amaro, Paulo; Ferreira, Pedro; Simões, Fernando
2018-05-01
In this study a tool with interchangeable inserts of sintered carbides coated with AlTiN were used to mill a duplex stainless steel with trochoidal strategies. Cutting speed range from 120 to 300 m/min were used and t he evaluation of tool deterioration and tool life was made according international standard ISO 8688-1. It was observed a progressive development of a flank wear and a cumulative cyclic process of localized adhesion of the chip to the cutting edge, followed by chipping, loss of the coating and substrate exposure. The tool life reached a maximum of 35 min. for cutting speed of 120 m/min. However, it was possible to maintain a tool life of 20-25 minutes when the cutting speed was increased up to 240 m/min.
NASA Astrophysics Data System (ADS)
Nor Khairusshima, M. K.; Hafiz Zakwan, B. Muhammad; Suhaily, M.; Sharifah, I. S. S.; Shaffiar, N. M.; Rashid, M. A. N.
2018-01-01
Carbon Fibre Reinforced Plastic (CFRP) composite has become one of famous materials in industry, such as automotive, aeronautics, aerospace and aircraft. CFRP is attractive due to its properties, which promising better strength and high specification of mechanical properties other than its high resistance to corrosion. Other than being abrasive material due to the carbon nature, CFRP is an anisotropic material, which the knowledge of machining metal and steel cannot be applied during machining CFRP. The improper technique and parameters used to machine CFRP may result in high tool wear. This paper is to study the tool wear of 8 mm diameter carbide cutting tool during milling CFRP. To predict the suitable cutting parameters within range of 3500-6220 (rev/min), 200-245 (mm/min), and 0.4-1.8 (mm) for cutting speed, speed, feed rate and depth of cut respectively, which produce optimized result (less tool wear), Response Surface Methodology (RSM) has been used. Based on the developed mathematical model, feed rate was identified as the primary significant item that influenced tool wear. The optimized cutting parameters are cutting speed, feed and depth of cut of 3500 rev/min, 200 mm/min and 0.5 mm, respectively, with tool wear of 0.0267 mm. It is also can be observed that as the cutting speed and feed rate increased the tool wear is increasing.
NASA Astrophysics Data System (ADS)
Shin, Jae Sung; Oh, Seong Yong; Park, Hyunmin; Chung, Chin-Man; Seon, Sangwoo; Kim, Taek-Soo; Lee, Lim; Lee, Jonghwan
2018-01-01
A cutting study with a high-power ytterbium-doped fiber laser was conducted for the dismantling of nuclear facilities. Stainless steel and carbon steel plates of various thicknesses were cut at a laser power of 6-kW. Despite the use of a low output of 6-kW, the cutting was successful for both stainless steel and carbon steel plates of up to 100 mm in thickness. In addition, the maximum cutting speeds against the thicknesses were obtained to evaluate the cutting performance. As representative results, the maximum cutting speeds for a 60-mm thickness were 72 mm/min for the stainless steel plates and 35 mm/min for the carbon steel plates, and those for a 100-mm thickness were 7 mm/min for stainless steel and 5 mm/min for carbon steel plates. These results show an efficient cutting capability of about 16.7 mm by kW, whereas other groups have shown cutting capabilities of ∼10 mm by kW. Moreover, the maximum cutting speeds were faster for the same thicknesses than those from other groups. In addition, the kerf widths of 60-mm and 100-mm thick steels were also obtained as another important parameter determining the amount of secondary waste. The front kerf widths were ∼1.0 mm and the rear kerf widths were larger than the front kerf widths but as small as a few millimeters.
Siegel, Sharon C; Patel, Tejas
2016-10-01
This study compared different diamond burs and different water flow rates on the cutting efficiency of sectioning through lithium disilicate glass ceramic. The authors used a standardized cutting regimen with 4 brands of diamond burs to section through lithium disilicate glass ceramic blocks. Twelve diamonds of each brand cut through the blocks in randomized order. In the first part of the study, the authors recorded sectioning rates in millimeters per minute for each diamond bur as a measure of cutting efficiency. In the second part of the study, the authors compared sectioning rates using only 1 brand of diamond bur, with 3 different water flow rates. The authors averaged and compared cutting rates of each brand of diamond bur and the cutting rates for each flow rate using an analysis of variance and determined the differences with a Tukey honest significant difference test. One diamond bur cut significantly slower than the other 3, and one diamond bur cut significantly faster than 2 of the others. The diamond bur cutting efficiency through lithium disilicate glass ceramic with a 20 mL/min water flow rate was significantly higher than 15 mL/min. There are differences in cutting efficiency between diamond burs when sectioning lithium disilicate glass ceramic. Use a minimum of 20 mL/min of water coolant flow when sectioning lithium disilicate glass ceramic with dental diamond burs to maximize cutting efficiency. Recommendations for specific diamond burs with a coarse grit and water flow rate of 20 mL/min can be made when removing or adjusting restorations made from lithium disilicate glass ceramic. Copyright © 2016 American Dental Association. Published by Elsevier Inc. All rights reserved.
Arelin, Viktor; Schmidt, Julius J; Kayser, Nathalie; Kühn-Velten, W Nikolaus; Suhling, Hendrik; Eden, Gabriele; Kielstein, Jan T
2016-06-01
The synthetic opioid methadone hydrochloride has a low molecular weight of 346 D, a high volume of distribution (4 - 7 L/kg), and is lipophilic. It is used as an analgesic and for the maintenance treatment of opiate dependence. In drug addicts, methadone is frequently involved in mixed intoxications that can lead to death. Here we present the case of a drug addict in whom a high cut-off dialysis membrane together with extended dialysis was used in the setting of suspected overdose and acute kidney injury. Although the observed dialyzer plasma clearance (31.5 mL/min) and reduction ratio (38%) were higher than previously reported for standard hemodialysis, the total amount of methadone in the spent dialysate after 1 extended dialysis session was quite low. Hence, even extended dialysis with a high cut-off membrane does not seem to offer a clinically relevant benefit in the setting of overdose for enhanced methadone removal. On the other hand, in patients undergoing high cut-off dialysis for the removal of light chains, methadone could still be used as an analgesic without an additional dose after high cut-off hemodialysis.
Løkke, Mette Marie; Edelenbos, Merete; Larsen, Erik; Feilberg, Anders
2012-01-01
Volatile organic compounds (VOCs) in cut onions (Allium cepa L.) were continuously measured by PTR-MS during the first 120 min after cutting. The headspace composition changed rapidly due to the very reactive volatile sulfurous compounds emitted from onion tissue after cell disruption. Mass spectral signals corresponding to propanethial S-oxide (the lachrymatory factor) and breakdown products of this compound dominated 0–10 min after cutting. Subsequently, propanethiol and dipropyl disulfide predominantly appeared, together with traces of thiosulfinates. The concentrations of these compounds reached a maximum at 60 min after cutting. Propanethiol was present in highest concentrations and had an odor activity value 20 times higher than dipropyl disulfide. Thus, propanethiol is suggested to be the main source of the characteristic onion odor. Monitoring the rapid changes of VOCs in the headspace of cut onion necessitates a high time resolution, and PTR-MS is demonstrated to be a very suitable method for monitoring the headspace of freshly cut onions directly after cutting without extraction or pre-concentration. PMID:23443367
Corneal cut closure using temperature-controlled CO2 laser soldering system.
Tal, Kfir; Strassmann, Eyal; Loya, Nino; Ravid, Avi; Kariv, Noam; Weinberger, Dov; Katzir, Abraham; Gaton, Dan D
2015-05-01
We aimed to evaluate the effectiveness of temperature-controlled laser soldering for repair of large perforated corneas in a porcine model. Eight Yorkshire pigs aged 6 months underwent 6-mm-deep 180° crescent-shaped trephination of the central corneas. Right corneal injuries were repaired by placement of 47 % bovine albumin along the cut followed by CO2 laser soldering (power density 16 W/cm(2)) to a target temperature of 65(°). Left corneal injuries were repaired with 10/0 nylon sutures. The groups were compared for operative time, leakage, and histopathological findings. Mean tissue temperature was 63 ± 4 °C. Mean operative time was 31.57 ± 2.8 min in laser-soldered eyes and 41.38 ± 2.3 min in controls (p < 0.0001, unpaired Student's t test). Compared to controls, the soldered corneas had less neovascularization, complete re-epithelization, and mild stromal inflammation. There was no leakage in either group. Combined CO2 laser and radiometer is effective for the in vivo repair of corneal cuts. These results have important implications for modern corneal surgery. Further studies are needed in the clinical setting.
Influence of microwave sterilization on the cutting capacity of carbide burs.
Fais, Laiza Maria Grassi; Pinelli, Lígia Antunes Pereira; Adabo, Gelson Luis; Silva, Regina Helena Barbosa Tavares da; Marcelo, Caroline Canhizares; Guaglianoni, Dalton Geraldo
2009-01-01
This study compared the cutting capacity of carbide burs sterilized with microwaves and traditional sterilization methods. Sixty burs were divided into 5 groups according to the sterilization methods: dry heat (G1), autoclave (G2), microwave irradiation (G3), glutaraldehyde (G4) or control - no sterilization (G5). The burs were used to cut glass plates in a cutting machine set for twelve 2.5-min periods and, after each period, they were sterilized (except G5) following the protocol established for each group. The cutting capacity of the burs was determined by a weight-loss method. Data were analyzed statistically by Kruskal-Wallis and Dunn's test. The means of the cutting amount performed by each group after the 12 periods were G1 = 0.2167 +/- 0.0627 g; G2 = 0.2077 +/- 0.0231 g; G3 = 0.1980 +/- 0.0326 g; G4 = 0.1203 +/- 0.0459 g; G5 = 0.2642 +/- 0.0359 g. There were statistically significant differences among the groups (p<0.05); only dry heat sterilization was similar to the control. Sterilization by dry heat was the method that least affected the cutting capacity of the carbide burs and microwave sterilization was not better than traditional sterilization methods.
Chiu, T-H; Duan, J; Liu, C; Su, Y-C
2006-12-01
To determine the efficacy of electrolysed oxidizing (EO) water in inactivating Vibrio parahaemolyticus on kitchen cutting boards and food contact surfaces. Cutting boards (bamboo, wood and plastic) and food contact surfaces (stainless steel and glazed ceramic tile) were inoculated with V. parahaemolyticus. Viable cells of V. parahaemolyticus were detected on all cutting boards and food contact surfaces after 10 and 30 min, respectively, at room temperatures. Soaking inoculated food contact surfaces and cutting boards in distilled water for 1 and 3 min, respectively, resulted in various reductions of V. parahaemolyticus, but failed to remove the organism completely from surfaces. However, the treatment of EO water [pH 2.7, chlorine 40 ppm, oxidation-reduction potential 1151 mV] for 30, 45, and 60 s, completely inactivated V. parahaemolyticus on stainless steel, ceramic tile, and plastic cutting boards, respectively. EO water could be used as a disinfecting agent for inactivating V. parahaemolyticus on plastic and wood cutting boards and food contact surfaces. Rinsing the food contact surfaces with EO water or soaking cutting boards in EO water for up to 5 min could be a simple strategy to reduce cross-contamination of V. parahaemolyticus during food preparation.
Wang, Bing; Liu, Zhanqiang; Hou, Xin; Zhao, Jinfu
2018-03-21
The paper aims to investigate the influences of material constitutive and fracture parameters in addition to cutting speed on chip formation during high-speed cutting of Inconel 718. Finite element analyses for chip formation are conducted with Johnson-Cook constitutive and fracture models. Meanwhile, experiments of high-speed orthogonal cutting are performed to verify the simulation results with cutting speeds ranging from 50 m/min to 7000 m/min. The research indicates that the chip morphology transforms from serrated to fragmented at the cutting speed of 7000 m/min due to embrittlement of the workpiece material under ultra-high cutting speeds. The parameter of shear localization sensitivity is put forward to describe the influences of material mechanical properties on serrated chip formation. The results demonstrate that the effects of initial yield stress and thermal softening coefficient on chip shear localization are much more remarkable than the other constitutive parameters. For the material fracture parameters, the effects of initial fracture strain and exponential factor of stress state on chip shear localization are more much prominent. This paper provides guidance for controlling chip formation through the adjustment of material mechanical properties and the selection of appropriate cutting parameters.
Hou, Xin; Zhao, Jinfu
2018-01-01
The paper aims to investigate the influences of material constitutive and fracture parameters in addition to cutting speed on chip formation during high-speed cutting of Inconel 718. Finite element analyses for chip formation are conducted with Johnson–Cook constitutive and fracture models. Meanwhile, experiments of high-speed orthogonal cutting are performed to verify the simulation results with cutting speeds ranging from 50 m/min to 7000 m/min. The research indicates that the chip morphology transforms from serrated to fragmented at the cutting speed of 7000 m/min due to embrittlement of the workpiece material under ultra-high cutting speeds. The parameter of shear localization sensitivity is put forward to describe the influences of material mechanical properties on serrated chip formation. The results demonstrate that the effects of initial yield stress and thermal softening coefficient on chip shear localization are much more remarkable than the other constitutive parameters. For the material fracture parameters, the effects of initial fracture strain and exponential factor of stress state on chip shear localization are more much prominent. This paper provides guidance for controlling chip formation through the adjustment of material mechanical properties and the selection of appropriate cutting parameters. PMID:29561770
Bae, Jin-Hyuk; Yi, Jaeyoung; Kim, Sungtae; Shim, June-Sung; Lee, Keun-Woo
2014-01-01
Cutting efficiency is one of the most important factors to consider when a specific dental diamond rotary instrument is selected. However, the selection of a dental diamond rotary instrument is based on clinical experience rather than any scientific evidence. The purpose of this study was to identify how the cutting efficiency of different types of dental diamond rotary instrument changed with repeated cuts and disinfection. Four types of diamond rotary instrument from 2 dental manufacturers (Shofu, Jin Dental) were investigated with a high-speed air-turbine handpiece. The groups were as follows: S cham group (n=10): chamfer design from Shofu; J cham group (n=10): chamfer design from Jin Dental; S thin group (n=10): thin tapered design from Shofu; J thin group (n=10): thin tapered design from Jin Dental. Changes in the cutting efficiency of diamond rotary instruments on glass ceramic blocks were measured after repeated cuts. Changes in cutting efficiency also were measured for 30 diamond rotary instruments, the same type as those used in group J cham after disinfection with ethylene oxide gas, immersion in solution, or autoclaving. One-way ANOVA, 2-way ANOVA, and repeated-measures ANOVA were used to identify differences in cutting efficiency, in total cutting efficiency, and change trend in cutting efficiency (α=.05). The Tukey honestly significant difference method was used for the post hoc tests. The principal metal components of the diamond rotary instruments were detected with x-ray spectrometry. The mean (standard deviation [SD]) total cutting efficiency after 10 cuts in the 4 groups was in the following order: J cham group (0.210 ± 0.064 g/min) > S cham group (0.170 ± 0.064 g/min) > J thin group (0.130 ± 0.042 g/min) > S thin group (0.010 ± 0.040 g/min) (P<.05).The decrease in the cutting efficiency was greatest after the first cut. The cutting efficiency was not influenced by repeated disinfection. The cutting efficiencies of diamond rotary instruments with different designs and particle sizes showed a decreasing trend after repeated cuts but did not show any change after various disinfecting procedures. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Bit Threads and Holographic Entanglement
NASA Astrophysics Data System (ADS)
Freedman, Michael; Headrick, Matthew
2017-05-01
The Ryu-Takayanagi (RT) formula relates the entanglement entropy of a region in a holographic theory to the area of a corresponding bulk minimal surface. Using the max flow-min cut principle, a theorem from network theory, we rewrite the RT formula in a way that does not make reference to the minimal surface. Instead, we invoke the notion of a "flow", defined as a divergenceless norm-bounded vector field, or equivalently a set of Planck-thickness "bit threads". The entanglement entropy of a boundary region is given by the maximum flux out of it of any flow, or equivalently the maximum number of bit threads that can emanate from it. The threads thus represent entanglement between points on the boundary, and naturally implement the holographic principle. As we explain, this new picture clarifies several conceptual puzzles surrounding the RT formula. We give flow-based proofs of strong subadditivity and related properties; unlike the ones based on minimal surfaces, these proofs correspond in a transparent manner to the properties' information-theoretic meanings. We also briefly discuss certain technical advantages that the flows offer over minimal surfaces. In a mathematical appendix, we review the max flow-min cut theorem on networks and on Riemannian manifolds, and prove in the network case that the set of max flows varies Lipshitz continuously in the network parameters.
High speed machinability of the aerospace alloy AA7075 T6 under different cooling conditions
NASA Astrophysics Data System (ADS)
Imbrogno, Stano; Rinaldi, Sergio; Suarez, Asier Gurruchaga; Arrazola, Pedro J.; Umbrello, Domenico
2018-05-01
This paper describes the results of an experimental investigation aimed to st udy the machinability of AA7075 T6 (160 HV) for aerospace industry at high cutting speeds. The paper investigates the effects of different lubri-cooling strategies (cryogenic, M QL and dry) during high speed turning process on cutting forces, tool wear, chip morphology and cutting temperatures. The cutting speeds selected were 1000m/min, 1250m/min and 1500 m/min, while the feed rate values used were 0.1mm/rev and 0.3 mm/rev. The results of cryogenic and M QL application is compared with dry application. It was found that the cryogenic and M QL lubri-cooling techniques could represent a functional alternative to the common dry cutting application in order to implement a more effect ive high speed turning process. Higher cuttingparameters would be able to increase the productivity and reduce the production costs. The effects of the cutting parameters and on the variables object of study were investigated and the role of the different lubri-cooling conditions was assessed.
NASA Astrophysics Data System (ADS)
Seon, Sangwoo; Shin, Jae Sung; Oh, Seong Yong; Park, Hyunmin; Chung, Chin-Man; Kim, Taek-Soo; Lee, Lim; Lee, Jonghwan
2018-07-01
A study was conducted to improve the cutting performance of a 60-mm thick stainless steel plate using a 6-kW fiber laser. Two techniques for improving the initial cutting performance were evaluated by preheating the work piece with a waiting time and step-like cutting speed increase. Both techniques showed improved cutting results compared to constant speed cutting. Among them, the method with a step-like cutting speed increase showed the better result in terms of cutting performance. As a result, a 60-mm thick stainless steel plate was cut at a maximum cutting speed of 72 mm/min with a preheating cutting speed of 24 mm/min. In order to confirm the effect of preheating, an additional experiment was performed to measure the temperature variation during the cutting process. Through this experiment, preheating temperature conditions were found to allow the specimen to be cut. It is expected that the results of this work will contribute to improving the cutting performance of thick metal structures in various industrial fields, as well as the dismantling of nuclear facilities using lasers in the future.
Min-cut segmentation of cursive handwriting in tabular documents
NASA Astrophysics Data System (ADS)
Davis, Brian L.; Barrett, William A.; Swingle, Scott D.
2015-01-01
Handwritten tabular documents, such as census, birth, death and marriage records, contain a wealth of information vital to genealogical and related research. Much work has been done in segmenting freeform handwriting, however, segmentation of cursive handwriting in tabular documents is still an unsolved problem. Tabular documents present unique segmentation challenges caused by handwriting overlapping cell-boundaries and other words, both horizontally and vertically, as "ascenders" and "descenders" overlap into adjacent cells. This paper presents a method for segmenting handwriting in tabular documents using a min-cut/max-flow algorithm on a graph formed from a distance map and connected components of handwriting. Specifically, we focus on line, word and first letter segmentation. Additionally, we include the angles of strokes of the handwriting as a third dimension to our graph to enable the resulting segments to share pixels of overlapping letters. Word segmentation accuracy is 89.5% evaluating lines of the data set used in the ICDAR2013 Handwriting Segmentation Contest. Accuracy is 92.6% for a specific application of segmenting first and last names from noisy census records. Accuracy for segmenting lines of names from noisy census records is 80.7%. The 3D graph cutting shows promise in segmenting overlapping letters, although highly convoluted or overlapping handwriting remains an ongoing challenge.
INFLUENCE OF MICROWAVE STERILIZATION ON THE CUTTING CAPACITY OF CARBIDE BURS
Fais, Laiza Maria Grassi; Pinelli, Lígia Antunes Pereira; Adabo, Gelson Luis; da Silva, Regina Helena Barbosa Tavares; Marcelo, Caroline Canhizares; Guaglianoni, Dalton Geraldo
2009-01-01
Objective: This study compared the cutting capacity of carbide burs sterilized with microwaves and traditional sterilization methods. Material and Methods: Sixty burs were divided into 5 groups according to the sterilization methods: dry heat (G1), autoclave (G2), microwave irradiation (G3), glutaraldehyde (G4) or control – no sterilization (G5). The burs were used to cut glass plates in a cutting machine set for twelve 2.5-min periods and, after each period, they were sterilized (except G5) following the protocol established for each group. The cutting capacity of the burs was determined by a weight-loss method. Data were analyzed statistically by Kruskal-Wallis and Dunn's test. Results: The means of the cutting amount performed by each group after the 12 periods were G1 = 0.2167 ± 0.0627 g; G2 = 0.2077 ± 0.0231 g; G3 = 0.1980 ± 0.0326 g; G4 = 0.1203 ± 0.0459 g; G5 = 0.2642 ± 0.0359 g. There were statistically significant differences among the groups (p<0.05); only dry heat sterilization was similar to the control. Conclusion: Sterilization by dry heat was the method that least affected the cutting capacity of the carbide burs and microwave sterilization was not better than traditional sterilization methods. PMID:20027431
The correlation between fetal bradycardia area in the second stage of labor and acidemia at birth.
Tranquilli, Andrea L; Biagini, Alessandra; Greco, Pantaleo; Di Tommaso, Mariarosaria; Giannubilo, Stefano R
2013-09-01
To quantify fetal bradycardia in the second stage of labor and to determine the threshold of the area that correlates with neonatal acidemia. We analyzed the cardiotocograms of 33 women with single pregnancy and term spontaneous labor who presented fetal bradycardia in the second stage of labor. We retrospectively calculated the fetal bradycardia area in the last 60 min before delivery with an upper limit of 90 bpm and correlated the area with neonatal pH. The study of the regression line determined the cut-off threshold between fetal well-being and distress. Significance was set at p < 0.05. The linear correlation between the bradycardia area and neonatal pH indicate that increasing bradycardia area was correlated with significant pH decrease. The threshold value of the area indicative of severe acidemia was ≥ 12.72 cm(2) (Pearson r = -0.76, p < 0.002). The diagnostic accuracy of the test was 73%. The PPV = 78.5% and the NPV = 68.4%. With such a cut-off, the timing of acidemia can be calculated as 25 min for a fetal heart rate (FHR) of 80 bpm, 13 min for a FHR of 70 bpm, 8 min for a FHR of 60 bpm, 6 min for a FHR of 50 bpm and 5 min for a FHR of 40 bpm. The bradycardia area in the second stage of labor significantly correlates with an accurate timing of fetal acidemia. Regardless of the cause of the bradycardia, the time for intervention is often short, meaning that any available intervention may be ineffective in preventing acidemia or even injury.
Handpiece coolant flow rates and dental cutting.
von Fraunhofer, J A; Siegel, S C; Feldman, S
2000-01-01
High-speed handpieces incorporate water coolant sprays to remove cutting debris and minimize thermal insult to the pulp. Little data exists on optimal coolant flow rates during clinical procedures. This study compared the effect of different coolant flow rates on diamond stone cutting efficiency. Cutting studies were performed on Macor machinable ceramic using a previously developed test regimen--a KaVo high-speed handpiece at a cutting force of 91.5 g (0.9 N). Cutting was performed with round end tapered medium grit diamond stones under cooling water flow rates of 15, 20, 25, 30 and 44 ml/min, with cutting rates determined as the time to transect the 13 mm square cross-section of the Macor bar. Each bur was used for five cuts, with six burs used for each flow rate, for a total of 150 measurements. The data were analyzed by one-way ANOVA with a post hoc Scheffé test. The cutting studies indicated that diamond stone cutting rates increased with higher coolant flow rates over the range of 15-44 ml/min. The data suggest that higher coolant flow rates promote cutting efficiency.
Ortiz-Flores, Andrés E; Santacruz, Elisa; Jiménez-Mendiguchia, Lucía; García-Cano, Ana; Nattero-Chávez, Lia; Escobar-Morreale, Héctor F; Luque-Ramírez, Manuel
2018-05-05
Aiming to validate the use of a single poststimulus sampling protocol for cosyntropin test short standard high-dose test (SST) in our institution, our primary objectives were (1) to determine the concordance between 30 and 60 min serum cortisol (SC) measurements during SST; and (2) to evaluate the diagnostic agreement between both sampling times when using classic or assay-specific and sex-specific SC cut-off values. The secondary objectives included (1) estimating the specificity and positive predictive value of 30 and 60 min sampling times while considering the suspected origin of adrenal insufficiency (AI); and (2) obtaining assay-specific cut-off values for SC after SST in a group of subjects with normal hypothalamic-pituitary-adrenal (HPA) axis. This is a retrospective chart review study conducted at a Spanish academic hospital from 2011 to 2015. Two groups were evaluated: (1) a main study group including 370 patients in whom SC was measured at 30 and 60 min during SST; and (2) a confirmative group that included 150 women presenting with a normal HPA axis in whom SST was conducted to rule out late-onset congenital adrenal hyperplasia. Diagnostic agreement between both sampling times was assessed by considering both classic (500 nmol/L) and assay-specific SC cut-off concentrations. Diagnostic agreement between both sampling times was greater when applying sex-specific and assay-specific cut-off values instead of the classic cut-off values. For suspected primary AI, 30 min SC determination was enough to establish a diagnosis in over 95% of cases, without missing any necessary treatment. When central AI is suspected, 60 min SC measurement was more specific, establishing a diagnosis in over 97% of cases. Sex-specific and assay-specific SC cut-off values improve the diagnostic accuracy of SST. For primary disease, a subnormal SC response at 30 min is a reliable marker of adrenal dysfunction. On the contrary, when central AI is suspected, 60 min SC measurement improves the diagnostic accuracy of the test. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Adegboye, Amanda R A; Anderssen, Sigmund A; Froberg, Karsten; Sardinha, Luis B; Heitmann, Berit L; Steene-Johannessen, Jostein; Kolle, Elin; Andersen, Lars B
2011-07-01
To define the optimal cut-off for low aerobic fitness and to evaluate its accuracy to predict clustering of risk factors for cardiovascular disease in children and adolescents. Study of diagnostic accuracy using a cross-sectional database. European Youth Heart Study including Denmark, Portugal, Estonia and Norway. 4500 schoolchildren aged 9 or 15 years. Aerobic fitness was expressed as peak oxygen consumption relative to bodyweight (mlO(2)/min/kg). Risk factors included in the composite risk score (mean of z-scores) were systolic blood pressure, triglyceride, total cholesterol/HDL-cholesterol ratio, insulin resistance and sum of four skinfolds. 14.5% of the sample, with a risk score above one SD, were defined as being at risk. Receiver operating characteristic analysis was used to define the optimal cut-off for sex and age-specific distribution. In girls, the optimal cut-offs for identifying individuals at risk were: 37.4 mlO(2)/min/kg (9-year-old) and 33.0 mlO(2)/min/kg (15-year-old). In boys, the optimal cut-offs were 43.6 mlO(2)/min/kg (9-year-old) and 46.0 mlO(2)/min/kg (15-year-old). Specificity (range 79.3-86.4%) was markedly higher than sensitivity (range 29.7-55.6%) for all cut-offs. Positive predictive values ranged from 19% to 41% and negative predictive values ranged from 88% to 90%. The diagnostic accuracy for identifying children at risk, measured by the area under the curve (AUC), was significantly higher than what would be expected by chance (AUC >0.5) for all cut-offs. Aerobic fitness is easy to measure, and is an accurate tool for screening children with clustering of cardiovascular risk factors. Promoting physical activity in children with aerobic fitness level lower than the suggested cut-points might improve their health.
Measuring moderate-intensity walking in older adults using the ActiGraph accelerometer.
Barnett, Anthony; van den Hoek, Daniel; Barnett, David; Cerin, Ester
2016-12-08
Accelerometry is the method of choice for objectively assessing physical activity in older adults. Many studies have used an accelerometer count cut point corresponding to 3 metabolic equivalents (METs) derived in young adults during treadmill walking and running with a resting metabolic rate (RMR) assumed at 3.5 mL · kg -1 · min -1 (corresponding to 1 MET). RMR is lower in older adults; therefore, their 3 MET level occurs at a lower absolute energy expenditure making the cut point derived from young adults inappropriate for this population. The few studies determining older adult specific moderate-to-vigorous intensity physical activity (MVPA) cut points had methodological limitations, such as not measuring RMR and using treadmill walking. This study determined a MVPA hip-worn accelerometer cut point for older adults using measured RMR and overground walking. Following determination of RMR, 45 older adults (mean age 70.2 ± 7 years, range 60-87.6 years) undertook an outdoor, overground walking protocol with accelerometer count and energy expenditure determined at five walking speeds. Mean RMR was 2.8 ± 0.6 mL · kg -1 · min -1 . The MVPA cut points (95% CI) determined using linear mixed models were: vertical axis 1013 (734, 1292) counts · min -1 ; vector magnitude 1924 (1657, 2192) counts · min -1 ; and walking speed 2.5 (2.2, 2.8) km · hr -1 . High levels of inter-individual variability in cut points were found. These MVPA accelerometer and speed cut points for walking, the most popular physical activity in older adults, were lower than those for younger adults. Using cut points determined in younger adults for older adult population studies is likely to underestimate time spent engaged in MVPA. In addition, prescription of walking speed based on the adult cut point is likely to result in older adults working at a higher intensity than intended.
NASA Astrophysics Data System (ADS)
Ravi, S.; Pradeep Kumar, M.
2011-09-01
Milling of hardened steel generates excessive heat during the chip formation process, which increases the temperature of cutting tool and accelerates tool wear. Application of conventional cutting fluid in milling process may not effectively control the heat generation also it has inherent health and environmental problems. To minimize health hazard and environmental problems caused by using conventional cutting fluid, a cryogenic cooling set up is developed to cool tool-chip interface using liquid nitrogen (LN 2). This paper presents results on the effect of LN 2 as a coolant on machinability of hardened AISI H13 tool steel for varying cutting speed in the range of 75-125 m/min during end milling with PVD TiAlN coated carbide inserts at a constant feed rate. The results show that machining with LN 2 lowers cutting temperature, tool flank wear, surface roughness and cutting forces as compared with dry and wet machining. With LN 2 cooling, it has been found that the cutting temperature was reduced by 57-60% and 37-42%; the tool flank wear was reduced by 29-34% and 10-12%; the surface roughness was decreased by 33-40% and 25-29% compared to dry and wet machining. The cutting forces also decreased moderately compared to dry and wet machining. This can be attributed to the fact that LN 2 machining provides better cooling and lubrication through substantial reduction in the cutting zone temperature.
Boris, Ronald S; Eun, Daniel; Bhandari, Akshay; Lyall, Kathryn; Bhandari, Mahendra; Rogers, Craig; Alassi, Osama; Menon, Mani
2007-01-01
A potassium-titanyl-phosphate (KTP) laser through robotic endo-wrist instrument has been evaluated as an ablative and hemostatic tool in robotic assisted laparoscopic partial nephrectomy (RALPN). Ten RALPN were performed in five domestic female pigs. The partial nephrectomies were performed with bulldog clamping of the pedicle. Flexible glass fiber carrying 532-nm green light laser was used through a robotic endowrist instrument in two cases. Power usage from 4 to 10 W was tested. The laser probe was explored both as a cutting knife and for hemostasis. The pelvicalyceal system was closed with a running suture. Partial nephrectomies using KTP laser were performed without complications. Mean operative times and warm ischemia times for laser cases were 96 and 18 min, respectively. Mean estimated blood loss was 60 ml compared with 50 ml for non-laser cases. Complete hemostasis with the laser alone could be achieved with a power of 4 W and was found to be effective. In our hands the laser fiber powered up to 10 W was not effective as a quick cutting agent. Histopathologic analysis of the renal remnant revealed a cauterized surface effect with average laser penetration depth less than 1 mm and minimal surrounding cellular injury. The new robotic endowrist instrument carrying flexible glass fiber transmitting 532-nm green light laser is a useful addition to the armamentarium of the robotic urologic setup. Its control by the console surgeon enables quicker and more complete hemostasis of the cut surface in renal sparing surgery using a porcine model. Histologically proven lased depth of less than 1 mm suggests minimal parenchyma damage in an acute setting. Laser application as a cutting agent, however, requires further investigation with interval power settings beyond the limits of this preliminary study. We estimate that effective cutting should be possible with a setting lower than traditionally recommended for solid organs.
Optimization of CO2 laser cutting parameters on Austenitic type Stainless steel sheet
NASA Astrophysics Data System (ADS)
Parthiban, A.; Sathish, S.; Chandrasekaran, M.; Ravikumar, R.
2017-03-01
Thin AISI 316L stainless steel sheet widely used in sheet metal processing industries for specific applications. CO2 laser cutting is one of the most popular sheet metal cutting processes for cutting of sheets in different profile. In present work various cutting parameters such as laser power (2000 watts-4000 watts), cutting speed (3500mm/min - 5500 mm/min) and assist gas pressure (0.7 Mpa-0.9Mpa) for cutting of AISI 316L 2mm thickness stainless sheet. This experimentation was conducted based on Box-Behenken design. The aim of this work is to develop a mathematical model kerf width for straight and curved profile through response surface methodology. The developed mathematical models for straight and curved profile have been compared. The Quadratic models have the best agreement with experimental data, and also the shape of the profile a substantial role in achieving to minimize the kerf width. Finally the numerical optimization technique has been used to find out best optimum laser cutting parameter for both straight and curved profile cut.
Estimation of tool wear length in finish milling using a fuzzy inference algorithm
NASA Astrophysics Data System (ADS)
Ko, Tae Jo; Cho, Dong Woo
1993-10-01
The geometric accuracy and surface roughness are mainly affected by the flank wear at the minor cutting edge in finish machining. A fuzzy estimator obtained by a fuzzy inference algorithm with a max-min composition rule to evaluate the minor flank wear length in finish milling is introduced. The features sensitive to minor flank wear are extracted from the dispersion analysis of a time series AR model of the feed directional acceleration of the spindle housing. Linguistic rules for fuzzy estimation are constructed using these features, and then fuzzy inferences are carried out with test data sets under various cutting conditions. The proposed system turns out to be effective for estimating minor flank wear length, and its mean error is less than 12%.
The membrane may be an important factor in browning of fresh-cut pear.
Li, Zhenghong; Zhang, Yuxing; Ge, Huibo
2017-09-01
Surface browning is an important cause of deterioration of fresh-cut fruit during postharvest handling. In this paper, four pear cultivars with different extents of natural browning were selected to analyse the factors involved in browning. The main results are as follows: the lipoxygenase (LOX) activity of 'Mantianhong' and 'Yali' pears was higher accompanied by a stronger degree of browning, while the LOX activity in 'Xueqing' and 'Xinli 7' pears was lower, with less browning. A higher unsaturated fatty acid ratio of pear resulted in reduced browning. The cell membranes disappeared 30min after being cut in 'Mantianhong' pear, which browns easily; however, the cell membranes were still intact 30min after being cut in 'Xueqing' pear, which does not brown easily. Therefore, it can be assumed that the stability of the cell membrane plays an important role in inhibiting browning of fresh-cut pears. Copyright © 2017. Published by Elsevier Ltd.
Honey in combination with vacuum impregnation to prevent enzymatic browning of fresh-cut apples.
Jeon, M; Zhao, Y
2005-05-01
This study evaluated the antioxidative capacity of 13 US Northwest honeys from different floral sources and their anti-browning effect on fresh-cut apples. The inhibitory effect of honey on enzymatic browning of fresh-cut apples were studied by simply immersing apple slices in 10% honey solution for 30 min or vacuum impregnating (vacuum at 75 mmHg for 15 min followed with 30 min restoration at atmospheric pressure) in the same honey solution. The 10% diluted high-fructose corn syrup solution was used as a comparison. The surface color of the apple slices was monitored during 14 days of storage at 3 degrees C and 90% relative humidity. Physicochemical properties of the apples immediately after treatment were also evaluated. Wildflower honey had the darkest color and the highest antioxidative capacity among all test honeys. Vacuum impregnation with honey was more effective in controlling browning discoloration than that of simple immersion treatment. Honey in combination with vacuum impregnating operation may have a great potential for developing high-quality fresh-cut fruits.
Pottel, Hans; Hoste, Liesbeth; Delanaye, Pierre
2015-05-01
The chronic kidney disease (CKD) classification system for children is similar to that for adults, with both mainly based on estimated glomerular filtration rate (eGFR) combined with fixed cut-off values. The main cut-off eGFR value used to define CKD is 60 mL/min/1.73 m(2), a value that is also applied for children older than 2 years of age, adolescents and young adults. Based on a literature search, we evaluated inclusion criteria for eGFR in clinical trials or research studies on CKD for children. We also collected information on direct measurements of GFR (mGFR) in children and adolescents, with the aim to estimate the normal reference range for GFR. Using serum creatinine (Scr) normal reference values and Scr-based eGFR-equations, we also evaluated the correspondence between Scr normal reference values and (e)GFR normal reference values. Based on our literature search, the inclusion of children in published CKD studies has been based on cut-off values for eGFR of >60 mL/min/1.73 m(2). The lower reference limits for mGFR far exceed this adult threshold. Using eGFR values calculated using Scr-based formulas, we found that abnormal Scr levels in children already correspond to eGFR values that are below a cut-off of 75 mL/min/1.73 m(2). Abnormal GFR in children, adolescents and young adults starts below 75 mL/min/1.73 m(2), and as abnormality is a sign of disease, we recommend referring children, adolescents and young adults with an (e)GFR of <75 mL/min/1.73 m(2) for further clinical assessment.
Human connectome module pattern detection using a new multi-graph MinMax cut model.
De, Wang; Wang, Yang; Nie, Feiping; Yan, Jingwen; Cai, Weidong; Saykin, Andrew J; Shen, Li; Huang, Heng
2014-01-01
Many recent scientific efforts have been devoted to constructing the human connectome using Diffusion Tensor Imaging (DTI) data for understanding the large-scale brain networks that underlie higher-level cognition in human. However, suitable computational network analysis tools are still lacking in human connectome research. To address this problem, we propose a novel multi-graph min-max cut model to detect the consistent network modules from the brain connectivity networks of all studied subjects. A new multi-graph MinMax cut model is introduced to solve this challenging computational neuroscience problem and the efficient optimization algorithm is derived. In the identified connectome module patterns, each network module shows similar connectivity patterns in all subjects, which potentially associate to specific brain functions shared by all subjects. We validate our method by analyzing the weighted fiber connectivity networks. The promising empirical results demonstrate the effectiveness of our method.
Establishing school day pedometer step count cut-points using ROC curves in low-income children.
Burns, Ryan D; Brusseau, Timothy A; Fu, You; Hannon, James C
2016-05-01
Previous research has not established pedometer step count cut-points that discriminate children that meet school day physical activity recommendations using a tri-axial ActiGraph accelerometer criterion. The purpose of this study was to determine step count cut-points that associate with 30min of school day moderate-to-vigorous physical activity (MVPA) in school-aged children. Participants included 1053 school-aged children (mean age=8.4±1.8years) recruited from three low-income schools from the state of Utah in the U.S. Physical activity was assessed using Yamax DigiWalker CW600 pedometers and ActiGraph wGT3X-BT triaxial accelerometers that were concurrently worn during school hours. Data were collected at each school during the 2014-2015 school year. Receiver operating characteristic (ROC) curves were used to determine pedometer step count cut-points that associated with at least 30min of MVPA during school hours. Cut-points were determined using the maximum Youden's J statistic (J max). For the total sample, the area-under-the-curve (AUC) was 0.77 (p<0.001) with a pedometer cut-point of 5505 steps (J max=0.46, Sensitivity=63%, Specificity=84%; Accuracy=76%). Step counts showed greater diagnostic ability in girls (AUC=0.81, p<0.001; Cut-point=5306 steps; Accuracy=78.8%) compared to boys (AUC=0.72, p<0.01; Cut-point=5786 steps; Accuracy=71.4%). Pedometer step counts showed good diagnostic ability in girls and fair diagnostic ability in boys for discriminating children that met at least 30min of MVPA during school hours. Copyright © 2016 Elsevier Inc. All rights reserved.
Hiura, Masahito; Nakajima, Osamu; Mori, Toshizumi; Kitano, Katsuya
2005-10-01
We evaluated the accuracy of visually reading the whole blood Rapicheck H-FABP panel test using the quantitative plasma H-FABP concentration as the reference. Consecutive patients with chest pain (n = 237) who were suspected of having acute myocardial infarction were recruited. The appearance of an evident test line within 5 min was given a grade of +3 (strongly positive), appearance within 15 min +2 (moderately positive) and the appearance of a weak test line within 15 min +1 (weakly positive). The concordance rates were 91.8% for positive, 70.1% for negative and 80.2% for overall. Plasma H-FABP concentrations were above the cut-off value for 9.2% of negative (0) results. Fifty percent of weakly positive (+1) and 25.0% of moderately positive (+2) results had H-FABP concentrations lower than the cut-off value. All of the strongly positive (+3) were above the cut-off value. These results suggested that the false-positive and false-negative results of Rapicheck H-FABP were caused by over or underestimation in visual reading when the plasma H-FABP concentration was near the cut-off concentration. Low accuracy of visual reading of Rapicheck H-FABP was due to poor estimation by manual reading around the cut-off value.
High-power CO(2) laser with a Gauss-core resonator for high-speed cutting of thin metal sheets.
Takenaka, Y; Nishimae, J; Tanaka, M; Motoki, Y
1997-01-01
A novel resonator, the Gauss-core resonator, based on a stable resonator configuration designed to yield a highly focusing beam operating in a large-volume TEM(00) mode, is presented. A 6.2 kW linearly polarized output beam with an M(2) factor of 1.7 is obtained experimentally for a high-power cw CO(2) laser. The capability of the Gauss-core resonator to process laser materials is also studied. We can cut 1-mm-thick mild (soft) steel with a maximum cutting speed of 58 m/min at 5.6 kW and 0.2-mm-thick steel 145 m/min at 2.8 kW.
Pedometer steps/min in physical education: does the pedometer matter?
Scruggs, Philip W
2013-01-01
The investigation sought to replicate previous Yamax physical education steps/min findings by quantifying physical activity via pedometry albeit with the Walk4Life (W4L) pedometer. Specifically, the objective was to determine steps/min cut point intervals for the 33% and 50% physical activity (i.e., percent of lesson time engaged in physical activity [%PA]) physical education guidelines via the W4L pedometer. Field-based criterion-referenced validation. Data were collected from 75 lessons on 411 fifth- through twelfth-grade (M(age)=13.83±2.17 y) participants who had concurrently measured pedometer and behavioural observation data. The W4L and Yamax pedometer outcome measure was steps/min, and observation measure was %PA. Pearson r correlation and diagnostic (i.e., sensitivity, specificity, and receiver-operating characteristic [ROC] curve) tests were conducted. (a) Steps/min and %PA demonstrated a strong relationship (W4L, r=0.96, p=0.0001; Yamax, r=0.96, p=0.0001), (b) W4L pedometer steps/min accurately discriminated (ROC area under curve ≥ 98%) between achievement or non-achievement of %PA guidelines, (c) the W4L steps/min cut point intervals for the 33%PA guideline (55.0-59.5) were significantly lower than those found for the Yamax pedometer (60.8-65.0), and (d) a borderline overlap was found between W4L (75.7-79.5) and Yamax (79.1-85.8) steps/min cut point intervals for the 50%PA guideline. W4L steps/min demonstrated a strong relationship with %PA, and outstanding accuracy for physical education physical activity guideline discrimination; however, steps/min values indicative of physical education physical activity guideline achievement is pedometer brand dependent, and should be considered for steps/min implementation and surveillance. Copyright © 2012 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Anan, Ruito; Matsuoka, Hironori; Ono, Hajime; Ryu, Takahiro; Nakae, Takashi; Shuto, Schuichi; Watanabe, Suguru; Sato, Yuta
2017-04-01
This study examined the improvements to the tool life and finished surface roughness by using water-miscible cutting fluids in carbon fiber reinforced plastics end milling. In cutting tests, it was found that the use of emulsion type, soluble type, and solution type cutting fluids improved tool life compared with the case of dry cutting. Specifically, significant differences in tool life were observed at a high cutting speed of 171 m/min. In addition, the finished surface exhibited a low level of roughness when the solution type cutting fluid was used, regardless of the cutting speed.
Superpixel Cut for Figure-Ground Image Segmentation
NASA Astrophysics Data System (ADS)
Yang, Michael Ying; Rosenhahn, Bodo
2016-06-01
Figure-ground image segmentation has been a challenging problem in computer vision. Apart from the difficulties in establishing an effective framework to divide the image pixels into meaningful groups, the notions of figure and ground often need to be properly defined by providing either user inputs or object models. In this paper, we propose a novel graph-based segmentation framework, called superpixel cut. The key idea is to formulate foreground segmentation as finding a subset of superpixels that partitions a graph over superpixels. The problem is formulated as Min-Cut. Therefore, we propose a novel cost function that simultaneously minimizes the inter-class similarity while maximizing the intra-class similarity. This cost function is optimized using parametric programming. After a small learning step, our approach is fully automatic and fully bottom-up, which requires no high-level knowledge such as shape priors and scene content. It recovers coherent components of images, providing a set of multiscale hypotheses for high-level reasoning. We evaluate our proposed framework by comparing it to other generic figure-ground segmentation approaches. Our method achieves improved performance on state-of-the-art benchmark databases.
Cutting efficiency of nickel-titanium rotary and reciprocating instruments after prolonged use.
Gambarini, Gianluca; Giansiracusa Rubini, Alessio; Sannino, Giampaolo; Di Giorgio, Gianni; Di Giorgio, Fabrizio; Piasecki, Lucila; Al-Sudani, Dina; Plotino, Gianluca; Testarelli, Luca
2016-01-01
The aim of the present study was to compare the cutting efficiency of Twisted File instruments used in continuous rotation or TF Adaptive motion and evaluate if prolonged use significantly affected their cutting ability. 20 new NiTi instruments were used in the present study (TF tip size 35, 0.06 taper; Sybron-Endo, Orange, CA, USA), divided into 2 subgroups of 10 instruments each, depending on which movement was selected on the endodontic motor. Group 1: TF instruments were activated using the program TF continuous rotation at 500 rpm and torque set at 2 N; Group 2: TF instruments were activated using the reciprocating TF Adaptive motion. Cutting efficiency was tested in a device developed to test the cutting ability of endodontic instruments. Each instrument cut 10 plastic blocks (10 uses) and the length of the surface cut in a plastic block after 1 min was measured in a computerized program with a precision of 0.1 mm. Maximum penetration depth was calculated after 1 use and after 10 uses, and mean and standard deviation (SD) of each group was calculated. Data were statistically analyzed with a one-way ANOVA test (P < 0.05). TF instruments used in continuous rotation (Group 1) cut a mean depth of 10.4 mm (SD = 0.6 mm) after the first use and 10.1 mm (SD 1.1 mm) after 10 uses, while TF instruments used with the Adaptive motion cut a mean depth of 9.9 mm (SD = 0.7 mm) after the first use and 9.6 mm (SD = 0.9 mm) after 10 uses. There was no statistically significant difference between the two groups investigated (P > 0.05) nor between instruments after 1 or 10 uses. In conclusion, the TFA motion showed a lateral cutting ability similar to continuous rotation and all tested instruments exhibited the same cutting ability after prolonged use.
Deza, M A; Araujo, M; Garrido, M J
2007-01-01
This study evaluated the efficacy of neutral electrolyzed water (NEW; 64.1 mg/liter of active chlorine) to reduce populations of Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, and Listeria monocytogenes on plastic and wooden kitchen cutting boards. Its effectiveness was compared with that of a sodium hypochlorite solution (NaClO; 62.3 mg/liter of active chlorine). Inoculated portions of cutting boards were rinsed in either NEW or NaClO solutions, or deionized water (control). Plastic boards were rinsed for 1 min and wooden boards for 1 and 5 min. After each treatment, the surviving population of each strain was determined on the surface and in the soaking water. No significant difference (P > or = 0.05) was found between the final populations of each strain with regard to the treatment solutions (NEW or NaClO). However, a significant difference (P < or = 0.05) was revealed between surface materials after 1 min of washing. Whereas in plastic boards the initial bacterial populations were reduced by 5 log CFU/50 cm2, in wooden cutting boards they underwent a reduction of <3 log CFU/50 cm2. A 5-min exposure time yielded reductions of about 4 log CFU/50 cm2. The surviving populations of all bacteria in NEW and NaCIO washing solutions were <1 log CFU/ml after soaking both surfaces. This study revealed that NEW treatment is an effective method for reducing microbial contamination on plastic and wooden cutting boards. NEW efficacy was comparable to that of NaCIO, with the advantage of having a larger storage time.
Ruiz, Jonatan R; Cavero-Redondo, Ivan; Ortega, Francisco B; Welk, Gregory J; Andersen, Lars B; Martinez-Vizcaino, Vicente
2016-09-26
Poor cardiorespiratory fitness is associated with cardiovascular disease risk factors. To perform a systematic review and meta-analysis of the relationship between poor cardiorespiratory fitness and cardiovascular disease risk in children and adolescents. Systematic literature search (1980 to 11 April 2015) for studies that determined a cardiorespiratory fitness cut point that predicted cardiovascular disease risk in children and adolescents. We identified 7 studies that included 9280 children and adolescents (49% girls) aged 8-19 years from 14 countries. Cardiovascular disease risk was already present in boys (6-39%) and girls (6-86%). Boys with low fitness (<41.8 mL/kg/min) had a 5.7 times greater likelihood of having cardiovascular disease risk (95% CI 4.8 to 6.7). The comparable diagnostic OR for girls with low fitness (<34.6 mL/kg/min) was 3.6 (95% CI 3.0 to 4.3). The 95% confidence region of cardiorespiratory fitness associated with low cardiovascular disease risk ranges, 41.8-47.0 mL/kg/min in boys (eg, stages 6-8 for a boy aged 15 years) and 34.6-39.5 mL/kg/min in girls (eg, stages 3-5 for a girl aged 15 years). The cardiorespiratory fitness cut point to avoid cardiovascular disease risk ranged 41.8 mL/kg/min in boys and was 34.6 mL/kg/min in girls. Fitness levels below 42 and 35 mL/kg/min for boys and girls, respectively, should raise a red flag. These translate to 6 and 3 stages on the shuttle run test for a boy and a girl, both aged 15 years, respectively. These cut points identify children and adolescents who may benefit from primary and secondary cardiovascular prevention programming. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
NASA Astrophysics Data System (ADS)
Bogoljubova, M. N.; Afonasov, A. I.; Kozlov, B. N.; Shavdurov, D. E.
2018-05-01
A predictive simulation technique of optimal cutting modes in the turning of workpieces made of nickel-based heat-resistant alloys, different from the well-known ones, is proposed. The impact of various factors on the cutting process with the purpose of determining optimal parameters of machining in concordance with certain effectiveness criteria is analyzed in the paper. A mathematical model of optimization, algorithms and computer programmes, visual graphical forms reflecting dependences of the effectiveness criteria – productivity, net cost, and tool life on parameters of the technological process - have been worked out. A nonlinear model for multidimensional functions, “solution of the equation with multiple unknowns”, “a coordinate descent method” and heuristic algorithms are accepted to solve the problem of optimization of cutting mode parameters. Research shows that in machining of workpieces made from heat-resistant alloy AISI N07263, the highest possible productivity will be achieved with the following parameters: cutting speed v = 22.1 m/min., feed rate s=0.26 mm/rev; tool life T = 18 min.; net cost – 2.45 per hour.
Finding minimum-quotient cuts in planar graphs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, J.K.; Phillips, C.A.
Given a graph G = (V, E) where each vertex v {element_of} V is assigned a weight w(v) and each edge e {element_of} E is assigned a cost c(e), the quotient of a cut partitioning the vertices of V into sets S and {bar S} is c(S, {bar S})/min{l_brace}w(S), w(S){r_brace}, where c(S, {bar S}) is the sum of the costs of the edges crossing the cut and w(S) and w({bar S}) are the sum of the weights of the vertices in S and {bar S}, respectively. The problem of finding a cut whose quotient is minimum for a graph hasmore » in recent years attracted considerable attention, due in large part to the work of Rao and Leighton and Rao. They have shown that an algorithm (exact or approximation) for the minimum-quotient-cut problem can be used to obtain an approximation algorithm for the more famous minimumb-balanced-cut problem, which requires finding a cut (S,{bar S}) minimizing c(S,{bar S}) subject to the constraint bW {le} w(S) {le} (1 {minus} b)W, where W is the total vertex weight and b is some fixed balance in the range 0 < b {le} {1/2}. Unfortunately, the minimum-quotient-cut problem is strongly NP-hard for general graphs, and the best polynomial-time approximation algorithm known for the general problem guarantees only a cut whose quotient is at mostO(lg n) times optimal, where n is the size of the graph. However, for planar graphs, the minimum-quotient-cut problem appears more tractable, as Rao has developed several efficient approximation algorithms for the planar version of the problem capable of finding a cut whose quotient is at most some constant times optimal. In this paper, we improve Rao`s algorithms, both in terms of accuracy and speed. As our first result, we present two pseudopolynomial-time exact algorithms for the planar minimum-quotient-cut problem. As Rao`s most accurate approximation algorithm for the problem -- also a pseudopolynomial-time algorithm -- guarantees only a 1.5-times-optimal cut, our algorithms represent a significant advance.« less
Finding minimum-quotient cuts in planar graphs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, J.K.; Phillips, C.A.
Given a graph G = (V, E) where each vertex v [element of] V is assigned a weight w(v) and each edge e [element of] E is assigned a cost c(e), the quotient of a cut partitioning the vertices of V into sets S and [bar S] is c(S, [bar S])/min[l brace]w(S), w(S)[r brace], where c(S, [bar S]) is the sum of the costs of the edges crossing the cut and w(S) and w([bar S]) are the sum of the weights of the vertices in S and [bar S], respectively. The problem of finding a cut whose quotient is minimummore » for a graph has in recent years attracted considerable attention, due in large part to the work of Rao and Leighton and Rao. They have shown that an algorithm (exact or approximation) for the minimum-quotient-cut problem can be used to obtain an approximation algorithm for the more famous minimumb-balanced-cut problem, which requires finding a cut (S,[bar S]) minimizing c(S,[bar S]) subject to the constraint bW [le] w(S) [le] (1 [minus] b)W, where W is the total vertex weight and b is some fixed balance in the range 0 < b [le] [1/2]. Unfortunately, the minimum-quotient-cut problem is strongly NP-hard for general graphs, and the best polynomial-time approximation algorithm known for the general problem guarantees only a cut whose quotient is at mostO(lg n) times optimal, where n is the size of the graph. However, for planar graphs, the minimum-quotient-cut problem appears more tractable, as Rao has developed several efficient approximation algorithms for the planar version of the problem capable of finding a cut whose quotient is at most some constant times optimal. In this paper, we improve Rao's algorithms, both in terms of accuracy and speed. As our first result, we present two pseudopolynomial-time exact algorithms for the planar minimum-quotient-cut problem. As Rao's most accurate approximation algorithm for the problem -- also a pseudopolynomial-time algorithm -- guarantees only a 1.5-times-optimal cut, our algorithms represent a significant advance.« less
Characterization of Particulate Fume and Oxides Emission from Stainless Steel Plasma Cutting.
Wang, Jun; Hoang, Tien; Floyd, Evan L; Regens, James L
2017-04-01
Plasma cutting is a metal fabrication process that employs an electrically conductive plasma arc to cut metals. The metal fume emitted from stainless steel plasma cutting may consist of hexavalent chromium (Cr6+), which is a carcinogen, and other toxicants. Overexposure to plasma cutting fume may cause pulmonary toxicity and other health effects. This study was to evaluate the effects of operation parameters (arc current and arc time) on the fume formation rates, Cr6+ and other oxides concentrations, particle size distributions (PSD), and particle morphology. A fume chamber and high-volume pump were used to collect fume produced from cutting ER308L stainless steel plates with arc currents varying between 20 and 50 A. The amount of fume collected on glass fiber filters was gravimetrically determined and normalized to arc time. Cr6+ and other oxides in the fume were analyzed using ion chromatography. PSD of the fume was examined using a scanning mobility particle sizer and an aerodynamic particle sizer for fine and coarse fractions, respectively. The particle morphology was imaged through a transmission electron microscope (TEM). Total fume generation rate increased with arc current and ranged from 16.5 mg min-1 at 20 A to 119.0 mg min-1 at 50 A. Cr6+ emissions (219.8-480.0 µg min-1) from the plasma cutting were higher than welding fume in a previous study. Nitrogen oxides level can be an indicator of oxidation level and Cr6+ formation (R = 0.93). Both PSD measurement and TEM images confirmed a multimodal size distribution. A high concentration of a fine fraction of particles with geometric mean sizes from 96 to 235 nm was observed. Higher arc current yielded more particles, while lower arc current was not able to penetrate the metal plates. Hence, the worker should optimize the arc current to balance cut performance and fume emission. The findings indicated that arc current was the dominant factor in fume emission from plasma cutting. Appropriate ventilation and respiratory protection should be used to reduce workers' exposure. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
NASA Astrophysics Data System (ADS)
Bashir, K.; Alkali, A. U.; Elmunafi, M. H. S.; Yusof, N. M.
2018-04-01
Recent trend in turning hardened materials have gained popularity because of its immense machinability benefits. However, several machining processes like thermal assisted machining and cryogenic machining have reveal superior machinability benefits over conventional dry turning of hardened materials. Various engineering materials have been studied. However, investigations on AISI O1 tool steel have not been widely reported. In this paper, surface finish and surface integrity dominant when hard turning AISI O1 tool steel is analysed. The study is focused on the performance of wiper coated ceramic tool with respect to surface roughness and surface integrity of hardened tool steel. Hard turned tool steel was machined at varying cutting speed of 100, 155 and 210 m/min and feed rate of 0.05, 0.125 and 0.20mm/rev. The depth of cut of 0.2mm was maintained constant throughout the machining trials. Machining was conducted using dry turning on 200E-axis CNC lathe. The experimental study revealed that the surface finish is relatively superior at higher cutting speed of 210m/min. The surface finish increases when cutting speed increases whereas surface finish is generally better at lower feed rate of 0.05mm/rev. The experimental study conducted have revealed that phenomena such as work piece vibration due to poor or improper mounting on the spindle also contributed to higher surface roughness value of 0.66Ra during turning at 0.2mm/rev. Traces of white layer was observed when viewed with optical microscope which shows evidence of cutting effects on the turned work material at feed rate of 0.2 rev/min
Aerosol penetration through a model transport system: Comparison of theory and experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
McFarland, A.R.; Wong, F.S.; Anand, N.K.
1991-09-01
Numerical predictions were made of aerosol penetration through a model transport system. A physical model of the system was constructed and tested in an aerosol wind tunnel to obtain comparative data. The system was 26.6 mm in diameter and consisted of an inlet and three straight sections (oriented horizontally, vertically, and at 45{degree}). Particle sizes covered a range in which losses were primarily caused by inertial and gravitational effects (3-25 {mu}m aerodynamic equivalent diameter (AED)). Tests were conducted at two flow rates (70 and 130 l/min) and two inlet orientations (parallel and perpendicular to the free stream). Wind speed wasmore » 3 m/s for all test cases. The cut points for aerosol penetration through the experimental model vis-a-vis the numerical results are as follows: At a flow rate of 70 l/min with the inlet at 0{degree}, the experimentally observed cut point was 16.2 {mu}m AED while the numerically predicted value was 18.2 {mu}m AED while the numerically predicted value was 18.2 {mu}m AED. At 130 l/min and 0{degree}, the experimental cut point was 12.8 {mu}m AED as compared with a numerically value of 13.7 {mu}m AED. At 70l/min and a 90{degree}, the experimental cut point was 12.0 {mu}m AED while the numerically calculated value was 11.1 {mu}m AED. Slopes of the experimental penetration curves are somewhat steeper than the numerically predicted counterparts.« less
Zhang, Xin-Quan; Yang, Wen-Yu; Wan, Yan; Ma, Ying-Mei; Zhu, Yong-Qun; Peng, Yan; Huang, Lin-Kai
2014-01-01
In order to find a way to induce rooting on cuttings of Hemarthria compressa cv. Ya’an under controlled conditions, a project was carried out to study the effect of naphthalene acetic acid (NAA) on rooting in stem cuttings and related physiological changes during the rooting process of Hemarthria compressa. The cuttings were treated with five concentrations of NAA (0, 100, 200 300, 400 mg/l) at three soaking durations (10, 20, 30 minutes), and cuttings without treatment were considered as control. Samples were planted immediately into pots after treatment. IAA-oxidase (IAAO) activity, peroxidase (POD) activity and polyphenol oxidase (PPO) activity were determined after planting. Results showed that NAA had positive effect on rooting at the concentration of 200 mg/l compared to other concentrations at 30 days after planting (DAP). Among the three soaking durations, 20 minutes (min) of 200 mg/l NAA resulted in higher percentages of rooting, larger numbers of adventitious roots and heavier root dry weight per cutting. The lowest IAAO activity was obtained when soaked at 200 mg/l NAA for 20 min soaking duration. This was consistent with the best rooting ability, indicating that the lower IAAO activity, the higher POD activity and PPO activity could be used as an indicator of better rooting ability for whip grass cuttings and might serve as a good marker for rooting ability in cuttings. PMID:24595064
NASA Astrophysics Data System (ADS)
Pan, Minqiang; Zeng, Dehuai; Tang, Yong
A novel multi-cutter milling process for multiple parallel microchannels with manifolds is proposed to address the challenge of mass manufacture as required for cost-effective commercial applications. Several slotting cutters are stacked together to form a composite tool for machining microchannels simultaneously. The feasibility of this new fabrication process is experimentally investigated under different machining conditions and reaction characteristics of methanol steam reforming for hydrogen production. The influences of cutting parameters and the composite tool on the microchannel qualities and burr formation are analyzed. Experimental results indicate that larger cutting speed, smaller feed rate and cutting depth are in favor of obtaining relatively good microchannel qualities and small burrs. Of all the cutting parameters considered in these experiments, 94.2 m min -1 cutting speed, 23.5 mm min -1 feed rate and 0.5 mm cutting depth are found to be the optimum value. According to the comparisons of experimental results of multi-cutter milling process and estimated one of other alternative methods, it is found that multi-cutter milling process shows much shorter machining time and higher work removal rate than that of other alternative methods. Reaction characteristics of methanol steam reforming in microchannels also indicate that multi-cutter milling process is probably suitable for a commercial application.
Peechakara, Seenia; Bena, James; Clarke, Nigel J; McPhaul, Michael J; Reitz, Richard E; Weil, Robert J; Recinos, Pablo; Kennedy, Laurence; Hamrahian, Amir H
2017-09-01
The appropriate cosyntropin dose during cosyntropin stimulation tests remains uncertain. We conducted a prospective, randomized pilot study to compare 1 μg IV low dose cosyntropin test, 25 μg IM medium dose cosyntropin test, and 250 μg IM standard dose cosyntropin test to evaluate secondary adrenal insufficiency. Insulin tolerance test was used as the gold standard. The study included patients with hypothalamic/pituitary disease (n = 10) with at least one pituitary axis deficiency other than ACTH deficiency and controls (n = 12). All tests were done in random order. Sensitivity and specificity were calculated for total cortisol and serum free cortisol cut-off levels during cosyntropin stimulation tests. The median (range) age and F/M sex ratios for patients and controls were 54 years (23-62), 2/8, and 33 years (21-51), 6/6, respectively. The best total cortisol cut-off during low dose cosyntropin test, medium dose cosyntropin test, 30 min and 60 min standard dose cosyntropin test were 14.6 μg/dL (100% sensitivity & specificity), 18.7 μg/dL (100% sensitivity, 88% specificity), 16.1 (100% sensitivity & specificity), and 19.5 μg/dL (100% sensitivity & specificity), respectively. There was no difference in the ROC curve for cortisol values between the cosyntropin stimulation tests (p > 0.41). Using a cortisol cut-off of 18 μg/dL during cosyntropin stimulation tests, only cortisol level at 30 min during standard dose cosyntropin test provided discrimination similar to insulin tolerance test. The best peak free cortisol cut-off levels were 1 μg/dL for insulin tolerance test, 0.9 μg/dL for low dose cosyntropin test, 0.9 μg/dL for medium dose cosyntropin test, and 0.9 μg/dL and 1.3 μg/dL for 30 min and 60 min standard dose cosyntropin test, respectively. All cosyntropin stimulation tests had excellent correlations with insulin tolerance test, when appropriate cut-offs were used. This pilot study does not suggest an advantage in using 25 μg cosyntropin dose during the cosyntropin stimulation test. A serum free cortisol cut-off of 0.9 μg/dL may be used as pass criterion during low dose cosyntropin test, standard dose cosyntropin test cosyntropin test, and 30 min standard dose cosyntropin test.
High speed turning of compacted graphite iron using controlled modulation
NASA Astrophysics Data System (ADS)
Stalbaum, Tyler Paul
Compacted graphite iron (CGI) is a material which emerged as a candidate material to replace cast iron (CI) in the automotive industry for engine block castings. Its thermal and mechanical properties allow the CGI-based engines to operate at higher cylinder pressures and temperatures than CI-based engines, allowing for lower fuel emissions and increased fuel economy. However, these same properties together with the thermomechanical wear mode in the CGI-CBN system result in poor machinability and inhibit CGI from seeing wide spread use in the automotive industry. In industry, machining of CGI is done only at low speeds, less than V = 200 m/min, to avoid encountering rapid wear of the cutting tools during cutting. Studies have suggested intermittent cutting operations such as milling suffer less severe tool wear than continuous cutting. Furthermore, evidence that a hard sulfide layer which forms over the cutting edge in machining CI at high speeds is absent during machining CGI is a major factor in the difference in machinability of these material systems. The present study addresses both of these issues by modification to the conventional machining process to allow intermittent continuous cutting. The application of controlled modulation superimposed onto the cutting process -- modulation-assisted machining (MAM) -- is shown to be quite effective in reducing the wear of cubic boron nitride (CBN) tools when machining CGI at high machining speeds (> 500 m/min). The tool life is at least 20 times greater than found in conventional machining of CGI. This significant reduction in wear is a consequence of reduction in the severity of the tool-work contact conditions with MAM. The propensity for thermochemical wear of CBN is thus reduced. It is found that higher cutting speed (> 700 m/min) leads to lower tool wear with MAM. The MAM configuration employing feed-direction modulation appears feasible for implementation at high speeds and offers a solution to this challenging class of industrial machining applications. This study's approach is by series of high speed turning tests of CGI with CBN tools, comparing conventional machining to MAM for similar parameters otherwise, by tool wear measurements and machinability observations.
Experimental and analytical investigation of the thermal necrosis in high-speed drilling of bone.
Shakouri, Ehsan; Sadeghi, Mohammad H; Maerefat, Mehdi; Shajari, Shaghayegh
2014-04-01
Bone loss due to thermo necrosis may weaken the purchase of surgically placed screws and pins, causing them to loosen postoperatively. The heat generated during the bone drilling is proportional to cutting speed and force and may be partially dissipated by the blood and tissue fluids, and somehow carried away by the chips formed. Increasing cutting speed will reduce cutting force and machining time. Therefore, it is of interest to study the effects of the increasing cutting speed on bone drilling characteristics. In this article, the effects of the increasing cutting speed ranging from 500 up to 18,000 r/min on the thrust force and the temperature rise are studied for bovine femur bone. The results of this study reveal that the high-speed drilling of 6000-7000 r/min may effectively reduce the two parameters of maximum cortical temperature and duration of exposure at temperatures above the allowable levels, which in turn reduce the probability of thermal necrosis in the drill site. This is due to the reduction of the cutting force and the increase in the chip disposal speed. However, more increases in the drill bit rotational speed result in an increase in the amount of temperature elevation, not because of sensible change in drilling force but a considerable increase in friction among the chips, drill bit and the hole walls.
Ferrentino, Giovanna; Balzan, Sara; Dorigato, Andrea; Pegoretti, Alessandro; Spilimbergo, Sara
2012-05-01
The objective of the present study was the evaluation of the effectiveness of supercritical carbon dioxide (SC-CO(2)) as a nonthermal technology for the pasteurization of fresh-cut coconut, as an example of ready-to-eat and minimally processed food. First, the inactivation kinetics of microbiota on coconut were determined using SC-CO(2) treatments (pressures at 8 and 12 MPa, temperatures from 24 to 45 °C, treatment times from 5 to 60 min). Second, the effects of SC-CO(2) on the hardness and microstructure of fresh-cut coconut processed at the optimal conditions for microbial reduction were investigated. SC-CO(2) treatment of 15 min at 45 °C and 12 MPa induced 4 log CFU/g reductions of mesophilic microorganisms, lactic acid bacteria, total coliforms, and yeasts and molds. The hardness of coconut was not affected by the treatment but the samples developed an irregular and disorderly microstructure. Results suggested the potential of SC-CO(2) in preserving fresh-cut fruits and ready-to-eat products. © 2012 Institute of Food Technologists®
CUTSETS - MINIMAL CUT SET CALCULATION FOR DIGRAPH AND FAULT TREE RELIABILITY MODELS
NASA Technical Reports Server (NTRS)
Iverson, D. L.
1994-01-01
Fault tree and digraph models are frequently used for system failure analysis. Both type of models represent a failure space view of the system using AND and OR nodes in a directed graph structure. Fault trees must have a tree structure and do not allow cycles or loops in the graph. Digraphs allow any pattern of interconnection between loops in the graphs. A common operation performed on digraph and fault tree models is the calculation of minimal cut sets. A cut set is a set of basic failures that could cause a given target failure event to occur. A minimal cut set for a target event node in a fault tree or digraph is any cut set for the node with the property that if any one of the failures in the set is removed, the occurrence of the other failures in the set will not cause the target failure event. CUTSETS will identify all the minimal cut sets for a given node. The CUTSETS package contains programs that solve for minimal cut sets of fault trees and digraphs using object-oriented programming techniques. These cut set codes can be used to solve graph models for reliability analysis and identify potential single point failures in a modeled system. The fault tree minimal cut set code reads in a fault tree model input file with each node listed in a text format. In the input file the user specifies a top node of the fault tree and a maximum cut set size to be calculated. CUTSETS will find minimal sets of basic events which would cause the failure at the output of a given fault tree gate. The program can find all the minimal cut sets of a node, or minimal cut sets up to a specified size. The algorithm performs a recursive top down parse of the fault tree, starting at the specified top node, and combines the cut sets of each child node into sets of basic event failures that would cause the failure event at the output of that gate. Minimal cut set solutions can be found for all nodes in the fault tree or just for the top node. The digraph cut set code uses the same techniques as the fault tree cut set code, except it includes all upstream digraph nodes in the cut sets for a given node and checks for cycles in the digraph during the solution process. CUTSETS solves for specified nodes and will not automatically solve for all upstream digraph nodes. The cut sets will be output as a text file. CUTSETS includes a utility program that will convert the popular COD format digraph model description files into text input files suitable for use with the CUTSETS programs. FEAT (MSC-21873) and FIRM (MSC-21860) available from COSMIC are examples of programs that produce COD format digraph model description files that may be converted for use with the CUTSETS programs. CUTSETS is written in C-language to be machine independent. It has been successfully implemented on a Sun running SunOS, a DECstation running ULTRIX, a Macintosh running System 7, and a DEC VAX running VMS. The RAM requirement varies with the size of the models. CUTSETS is available in UNIX tar format on a .25 inch streaming magnetic tape cartridge (standard distribution) or on a 3.5 inch diskette. It is also available on a 3.5 inch Macintosh format diskette or on a 9-track 1600 BPI magnetic tape in DEC VAX FILES-11 format. Sample input and sample output are provided on the distribution medium. An electronic copy of the documentation in Macintosh Microsoft Word format is included on the distribution medium. Sun and SunOS are trademarks of Sun Microsystems, Inc. DEC, DeCstation, ULTRIX, VAX, and VMS are trademarks of Digital Equipment Corporation. UNIX is a registered trademark of AT&T Bell Laboratories. Macintosh is a registered trademark of Apple Computer, Inc.
An, Qinglong; Ming, Weiwei; Chen, Ming
2015-01-01
Ductile cutting are most widely used in fabricating high-quality optical glass components to achieve crack-free surfaces. For ultra-precision machining of brittle glass materials, critical undeformed chip thickness (CUCT) commonly plays a pivotal role in determining the transition point from ductile cutting to brittle cutting. In this research, cutting characteristics in nanometric cutting of BK7 and fused silica glasses, including machined surface morphology, surface roughness, cutting force and specific cutting energy, were investigated with nanometric plunge-cutting experiments. The same cutting speed of 300 mm/min was used in the experiments with single-crystal diamond tool. CUCT was determined according to the mentioned cutting characteristics. The results revealed that 320 nm was found as the CUCT in BK7 cutting and 50 nm was determined as the size effect of undeformed chip thickness. A high-quality machined surface could be obtained with the undeformed chip thickness between 50 and 320 nm at ductile cutting stage. Moreover, no CUCT was identified in fused silica cutting with the current cutting conditions, and brittle-fracture mechanism was confirmed as the predominant chip-separation mode throughout the nanometric cutting operation. PMID:28788010
An, Qinglong; Ming, Weiwei; Chen, Ming
2015-03-27
Ductile cutting are most widely used in fabricating high-quality optical glass components to achieve crack-free surfaces. For ultra-precision machining of brittle glass materials, critical undeformed chip thickness (CUCT) commonly plays a pivotal role in determining the transition point from ductile cutting to brittle cutting. In this research, cutting characteristics in nanometric cutting of BK7 and fused silica glasses, including machined surface morphology, surface roughness, cutting force and specific cutting energy, were investigated with nanometric plunge-cutting experiments. The same cutting speed of 300 mm/min was used in the experiments with single-crystal diamond tool. CUCT was determined according to the mentioned cutting characteristics. The results revealed that 320 nm was found as the CUCT in BK7 cutting and 50 nm was determined as the size effect of undeformed chip thickness. A high-quality machined surface could be obtained with the undeformed chip thickness between 50 and 320 nm at ductile cutting stage. Moreover, no CUCT was identified in fused silica cutting with the current cutting conditions, and brittle-fracture mechanism was confirmed as the predominant chip-separation mode throughout the nanometric cutting operation.
Surface morphology study in high speed milling of soda lime glass
NASA Astrophysics Data System (ADS)
Konneh, Mohamed; Bagum, Mst. Nasima; Ali, Mohammad Yeakub; Amin, A. K. M. Nurul
2018-05-01
Soda lime glass has a wide range of applications in optical, bio-medical and semi-conductor industries. It is undeniably a challenging task to produce micro finish surface on an amorphous brittle solid like soda lime glass due to its low fracture toughness. In order to obtain such a finish surface, ductile machining has been exploited, as this usually cause's plastic flow which control crack propagation. At sub-micro scale cutting parameters, researchers achieved nano finish surface in micro milling operation using coated tool. However it is possible to enhance the rate of material removal (RMR) of soda lime glass at flexible cutting condition. High speed cutting at micro meter level, extend of thermal softening might be prominent than the strain gradient strengthening. The purpose of this study was to explore the effects of high cutting speed end milling parameters on the surface texture of soda lime glass using uncoated carbide tool. The spindle speed, depth of cut and feed rate were varied from 20,000 to 40,000 rpm, 10 to 30 mm/min and 30 to 50 µm respectively. Mathematical model of roughness has been developed using Response Surface Methodology (RSM). Experimental verification confirmed that surface roughness (Ra) 0.38 µm is possible to achieve at increased RMR, 4.71 mm3/min.
Erdakov, Ivan Nikolaevich; Taha, Mohamed~Adel; Soliman, Mahmoud Sayed; El Rayes, Magdy Mostafa
2018-01-01
Magnesium alloys are widely used in aerospace vehicles and modern cars, due to their rapid machinability at high cutting speeds. A novel Edgeworth–Pareto optimization of an artificial neural network (ANN) is presented in this paper for surface roughness (Ra) prediction of one component in computer numerical control (CNC) turning over minimal machining time (Tm) and at prime machining costs (C). An ANN is built in the Matlab programming environment, based on a 4-12-3 multi-layer perceptron (MLP), to predict Ra, Tm, and C, in relation to cutting speed, vc, depth of cut, ap, and feed per revolution, fr. For the first time, a profile of an AZ61 alloy workpiece after finish turning is constructed using an ANN for the range of experimental values vc, ap, and fr. The global minimum length of a three-dimensional estimation vector was defined with the following coordinates: Ra = 0.087 μm, Tm = 0.358 min/cm3, C = $8.2973. Likewise, the corresponding finish-turning parameters were also estimated: cutting speed vc = 250 m/min, cutting depth ap = 1.0 mm, and feed per revolution fr = 0.08 mm/rev. The ANN model achieved a reliable prediction accuracy of ±1.35% for surface roughness. PMID:29772670
Silva, Diego Augusto; Tremblay, Mark; Pelegrini, Andreia; Dos Santos Silva, Roberto Jeronimo; Cabral de Oliveira, Antonio Cesar; Petroski, Edio Luiz
2016-05-01
Criterion-referenced cut-points for health-related fitness measures are lacking. This study aimed to determine the associations between aerobic fitness and high blood pressure levels (HBP) to determine the cut-points that best predict HBP among adolescents. This cross-sectional school-based study with sample of 875 adolescents aged 14-19 years was conducted in southern Brazil. Aerobic fitness was assessed using the modified Canadian Aerobic Fitness Test (mCAFT). Systolic and diastolic blood pressure were measured by the oscillometric method with a digital sphygmomanometer. Analyses controlled for sociodemographic variables, physical activity, body mass and biological maturation. Receiver Operating Characteristic (ROC) curves demonstrated that mCAFT measures could discriminate HBP in both sexes (female: AUC = 0.70; male: AUC = 0.63). The cut-points with the best discriminatory power for HBP were 32 mL·kg-1·min-1 for females and 40 mL·kg-1·min-1 for males. Females (OR = 8.4; 95% CI: 2.1, 33.7) and males (OR: 2.5; CI 95%: 1.2, 5.2) with low aerobic fitness levels were more likely to have HBP. mCAFT measures are inversely associated with BP and cut-points from ROC analyses have good discriminatory power for HBP.
ERIC Educational Resources Information Center
Lin, Jie
2006-01-01
The Bookmark standard-setting procedure was developed to address the perceived problems with the most popular method for setting cut-scores: the Angoff procedure (Angoff, 1971). The purposes of this article are to review the Bookmark procedure and evaluate it in terms of Berk's (1986) criteria for evaluating cut-score setting methods. The…
NASA Astrophysics Data System (ADS)
Wu, Ray Chun Tung; Chung, C. Y.
2012-12-01
To determine the variation of A f along the axial length of rotary nickel-titanium endodontic files (RNEF). Three commercial brands of 4% taper RNEF: GTX (#20, 25 mm, Dentsply Tulsa Dental Specialties, Tulsa, OK, USA), K3 (#25, 25 mm) and TF (Twisted File #25, 27 mm) (Sybron Kerr, Orange, CA, USA) were cut into segments at 4 mm increment from the working tip. Regional specimens were measured for differential heat-flow over thermal cycling, generally with continuous heating or cooling (5 °C/min) and 5 min hold at set temperatures (start, finish temperatures): GTX: -55, 90 °C; K3: -55, 45 °C; TF: -55, 60 °C; using differential scanning calorimeter. This experiment demonstrated regional differences in A f along the axial length of GTX and K3 files. Similar variation was not obvious in the TF samples. A contributory effect of regional difference in strain-hardening due to grinding and machining during manufacturing is proposed.
Multi-phase simultaneous segmentation of tumor in lung 4D-CT data with context information.
Shen, Zhengwen; Wang, Huafeng; Xi, Weiwen; Deng, Xiaogang; Chen, Jin; Zhang, Yu
2017-01-01
Lung 4D computed tomography (4D-CT) plays an important role in high-precision radiotherapy because it characterizes respiratory motion, which is crucial for accurate target definition. However, the manual segmentation of a lung tumor is a heavy workload for doctors because of the large number of lung 4D-CT data slices. Meanwhile, tumor segmentation is still a notoriously challenging problem in computer-aided diagnosis. In this paper, we propose a new method based on an improved graph cut algorithm with context information constraint to find a convenient and robust approach of lung 4D-CT tumor segmentation. We combine all phases of the lung 4D-CT into a global graph, and construct a global energy function accordingly. The sub-graph is first constructed for each phase. A context cost term is enforced to achieve segmentation results in every phase by adding a context constraint between neighboring phases. A global energy function is finally constructed by combining all cost terms. The optimization is achieved by solving a max-flow/min-cut problem, which leads to simultaneous and robust segmentation of the tumor in all the lung 4D-CT phases. The effectiveness of our approach is validated through experiments on 10 different lung 4D-CT cases. The comparison with the graph cut without context constraint, the level set method and the graph cut with star shape prior demonstrates that the proposed method obtains more accurate and robust segmentation results.
Modeling and Analysis of CNC Milling Process Parameters on Al3030 based Composite
NASA Astrophysics Data System (ADS)
Gupta, Anand; Soni, P. K.; Krishna, C. M.
2018-04-01
The machining of Al3030 based composites on Computer Numerical Control (CNC) high speed milling machine have assumed importance because of their wide application in aerospace industries, marine industries and automotive industries etc. Industries mainly focus on surface irregularities; material removal rate (MRR) and tool wear rate (TWR) which usually depends on input process parameters namely cutting speed, feed in mm/min, depth of cut and step over ratio. Many researchers have carried out researches in this area but very few have taken step over ratio or radial depth of cut also as one of the input variables. In this research work, the study of characteristics of Al3030 is carried out at high speed CNC milling machine over the speed range of 3000 to 5000 r.p.m. Step over ratio, depth of cut and feed rate are other input variables taken into consideration in this research work. A total nine experiments are conducted according to Taguchi L9 orthogonal array. The machining is carried out on high speed CNC milling machine using flat end mill of diameter 10mm. Flatness, MRR and TWR are taken as output parameters. Flatness has been measured using portable Coordinate Measuring Machine (CMM). Linear regression models have been developed using Minitab 18 software and result are validated by conducting selected additional set of experiments. Selection of input process parameters in order to get best machining outputs is the key contributions of this research work.
Surface Roughness Optimization Using Taguchi Method of High Speed End Milling For Hardened Steel D2
NASA Astrophysics Data System (ADS)
Hazza Faizi Al-Hazza, Muataz; Ibrahim, Nur Asmawiyah bt; Adesta, Erry T. Y.; Khan, Ahsan Ali; Abdullah Sidek, Atiah Bt.
2017-03-01
The main challenge for any manufacturer is to achieve higher quality of their final products with maintains minimum machining time. In this research final surface roughness analysed and optimized with maximum 0.3 mm flank wear length. The experiment was investigated the effect of cutting speed, feed rate and depth of cut on the final surface roughness using D2 as a work piece hardened to 52-56 HRC, and coated carbide as cutting tool with higher cutting speed 120-240 mm/min. The experiment has been conducted using L9 design of Taguchi collection. The results have been analysed using JMP software.
Chakraborty, Subir Kumar; Kumbhar, Baburao K; Chakraborty, Shalini; Yadav, Pravesh
2011-04-01
Five blends of refined wheat flour (RWF) (63.2 - 96.8, %RWF) and millet were used to manufacture biscuits baked for varying time (3.3-6.7 min) and temperature (166.6 - 183.4 °C). The manufactured biscuits were evaluated in terms of textural attributes (crispness, hardness and cutting strength) and overall acceptability (OAA). Results showed that increasing the amount of RWF in biscuits decreased (p < 0.01) hardness. Prolonging the baking time led to a decrease (p < 0.01) in hardness and cutting strength and a significant increase (p < 0.05) in OAA. Increase in baking temperature was followed by an increase in crispness (p < 0.01) and OAA (p < 0.1), while hardness and cutting strength (p < 0.01) decreased. Optimum processing condition generated form the models was, - blend ratio, 90%RWF; baking time, 6 min and baking temperature, 170 °C. The predicted responses in terms of crispness, hardness, cutting strength and OAA were 45, 0.3N, 27.2N and 8.9, respectively. The desirability of the optimum conditions was 0.98.
Cutting film violence: effects on perceptions, enjoyment, and arousal.
Berry, M; Gray, T; Donnerstein, E
1999-10-01
The authors investigated the effects of cutting specific graphic scenes of film violence on self-reports of arousal, enjoyability, and perceptions of violence among a sample of U.S. students. In 3 studies, they varied film exposure from 1 1/2 min in the 1st study to a complete motion picture (American vs. British version of same film) in the 3rd. In all 3 studies, the participants rated the cut versions as less violent than the uncut versions. The participants distinguished quite subtle differences in levels of violence, even when the cuts were minor and contextualized within an entire movie. Cutting the movie significantly increased its enjoyability for the women; for the men, there was no significant difference. Cutting violent films made no difference in arousal for the men but substantially lowered self-report levels of arousal for the women.
Liu, Yingzi; Yang, Xiuqin; Jing, Xiaoyan; He, Xinmiao; Wang, Liang; Liu, Yang; Liu, Di
2017-01-01
The Min pig (Sus scrofa) is a well-known indigenous breed in China. One of its main advantages over European breeds is its high meat quality. Additionally, different cuts of pig also show some different traits of meat quality. To explore the underlying mechanism responsible for the differences of meat quality between different breeds or cuts, the longissimus dorsi muscle (LM) and the biceps femoris muscle (BF) from Min and Large White pigs were investigated using transcriptome analysis. The gene expression profiling identified 1371 differentially expressed genes (DEGs) between LM muscles from Min and Large White pigs, and 114 DEGs between LM and BF muscles from the same Min pigs. Gene Ontology (GO) enrichment of biological functions and Kyoto Encyclopedia of Genes and Genomes (KEGG) analysis showed that the gene products were mainly involved in the IRS1/Akt/FoxO1 signaling pathway, adenosine 5′-monophosphate-activated protein kinase (AMPK) cascade effects, lipid metabolism and amino acid metabolism pathway. Such pathways contributed to fatty acid metabolism, intramuscular fat deposition, and skeletal muscle growth in Min pig. These results give an insight into the mechanisms underlying the formation of skeletal muscle and provide candidate genes for improving meat quality. It will contribute to improving meat quality of pigs through molecular breeding. PMID:29271915
Sinclair, R C F; Batterham, A M; Davies, S; Cawthorn, L; Danjoux, G R
2012-01-01
For perioperative risk stratification, a robust, practical test could be used where cardiopulmonary exercise testing (CPET) is unavailable. The aim of this study was to assess the utility of the 6 min walk test (6MWT) distance to discriminate between low and high anaerobic threshold (AT) in patients awaiting major non-cardiac surgery. In 110 participants, we obtained oxygen consumption at the AT from CPET and recorded the distance walked (in m) during a 6MWT. Receiver operating characteristic (ROC) curve analysis was used to derive two different cut-points for 6MWT distance in predicting an AT of <11 ml O(2) kg(-1) min(-1); one using the highest sum of sensitivity and specificity (conventional method) and the other adopting a 2:1 weighting in favour of sensitivity. In addition, using a novel linear regression-based technique, we obtained lower and upper cut-points for 6MWT distance that are predictive of an AT that is likely to be (P≥0.75) <11 or >11 ml O(2) kg(-1) min(-1). The ROC curve analysis revealed an area under the curve of 0.85 (95% confidence interval, 0.77-0.91). The optimum cut-points were <440 m (conventional method) and <502 m (sensitivity-weighted approach). The regression-based lower and upper 6MWT distance cut-points were <427 and >563 m, respectively. Patients walking >563 m in the 6MWT do not routinely require CPET; those walking <427 m should be referred for further evaluation. In situations of 'clinical uncertainty' (≥427 but ≤563 m), the number of clinical risk factors and magnitude of surgery should be incorporated into the decision-making process. The 6MWT is a useful clinical tool to screen and risk stratify patients in departments where CPET is unavailable.
Al-Qadiri, Hamzah M; Ovissipour, Mahmoudreza; Al-Alami, Nivin; Govindan, Byju N; Shiroodi, Setareh Ghorban; Rasco, Barbara
2016-05-01
Bactericidal activity of neutral electrolyzed water (NEW), quaternary ammonium (QUAT), and lactic acid-based solutions was investigated using a manual spraying technique against Salmonella Typhimurium, Escherichia coli O157:H7, Campylobacter jejuni, Listeria monocytogenes and Staphylococcus aureus that were inoculated onto the surface of scarred polypropylene and wooden food cutting boards. Antimicrobial activity was also examined when using cutting boards in preparation of raw chopped beef, chicken tenders or salmon fillets. Viable counts of survivors were determined as log10 CFU/100 cm(2) within 0 (untreated control), 1, 3, and 5 min of treatment at ambient temperature. Within the first minute of treatment, NEW and QUAT solutions caused more than 3 log10 bacterial reductions on polypropylene surfaces whereas less than 3 log10 reductions were achieved on wooden surfaces. After 5 min of treatment, more than 5 log10 reductions were achieved for all bacterial strains inoculated onto polypropylene surfaces. Using NEW and QUAT solutions within 5 min reduced Gram-negative bacteria by 4.58 to 4.85 log10 compared to more than 5 log10 reductions in Gram-positive bacteria inoculated onto wooden surfaces. Lactic acid treatment was significantly less effective (P < 0.05) compared to NEW and QUAT treatments. A decline in antimicrobial effectiveness was observed (0.5 to <2 log10 reductions were achieved within the first minute) when both cutting board types were used to prepare raw chopped beef, chicken tenders or salmon fillets. © 2016 Institute of Food Technologists®
Study on Finite Element Method of Stress Field in Aluminum Alloy High-Speed Milling Process
NASA Astrophysics Data System (ADS)
Zhang, Wei; Li, Shunming; Wu, Qijun; An, Zenghui
2017-11-01
Three-dimensional numerical simulation model has been built by means of Advantage FEM. Perform simulation the stress fields of 7050-T7451 aluminum alloy in high speed milling process at the speed range of 628 m/min∼5946 m/min. The dynamic change and speed’s influence of stress fields and residual stress in machined layer is systematically analyzed. Some conclusions were drawn. With the cutting process development, the stress field converts to the stress state that crushing stress occupies a leading position. The magnitudes of crushing stress in all directions reduce with milling processes as the effect of Thermal-Mechanical-Coupled weakens; With the cutting speed increasing the magnitudes of crushing stress in all directions fluctuate near -950Mpa first, and then increase at the speed of 3000m/min; The residual pulling stress beneath the surface 0.03mm has been found and the magnitude increases with the cutting speed. A good agreement was obtained between predictions and experiments.
CO 2 laser cutting of MDF . 1. Determination of process parameter settings
NASA Astrophysics Data System (ADS)
Lum, K. C. P.; Ng, S. L.; Black, I.
2000-02-01
This paper details an investigation into the laser processing of medium-density fibreboard (MDF). Part 1 reports on the determination of process parameter settings for the effective cutting of MDF by CO 2 laser, using an established experimental methodology developed to study the interrelationship between and effects of varying laser set-up parameters. Results are presented for both continuous wave (CW) and pulse mode (PM) cutting, and the associated cut quality effects have been commented on.
Abbas, Adel Taha; Pimenov, Danil Yurievich; Erdakov, Ivan Nikolaevich; Taha, Mohamed Adel; Soliman, Mahmoud Sayed; El Rayes, Magdy Mostafa
2018-05-16
Magnesium alloys are widely used in aerospace vehicles and modern cars, due to their rapid machinability at high cutting speeds. A novel Edgeworth⁻Pareto optimization of an artificial neural network (ANN) is presented in this paper for surface roughness ( Ra ) prediction of one component in computer numerical control (CNC) turning over minimal machining time ( T m ) and at prime machining costs ( C ). An ANN is built in the Matlab programming environment, based on a 4-12-3 multi-layer perceptron (MLP), to predict Ra , T m , and C , in relation to cutting speed, v c , depth of cut, a p , and feed per revolution, f r . For the first time, a profile of an AZ61 alloy workpiece after finish turning is constructed using an ANN for the range of experimental values v c , a p , and f r . The global minimum length of a three-dimensional estimation vector was defined with the following coordinates: Ra = 0.087 μm, T m = 0.358 min/cm³, C = $8.2973. Likewise, the corresponding finish-turning parameters were also estimated: cutting speed v c = 250 m/min, cutting depth a p = 1.0 mm, and feed per revolution f r = 0.08 mm/rev. The ANN model achieved a reliable prediction accuracy of ±1.35% for surface roughness.
NASA Astrophysics Data System (ADS)
Rahman, Mohamed Abd; Yeakub Ali, Mohammad; Saddam Khairuddin, Amir
2017-03-01
This paper presents the study on vibration and surface roughness of Inconel 718 workpiece produced by micro end-milling using Mikrotools Integrated Multi-Process machine tool DT-110 with control parameters; spindle speed (15000 rpm and 30000 rpm), feed rate (2 mm/min and 4 mm/min) and depth of cut (0.10 mm and 0.15mm). The vibration was measured using DYTRAN accelerometer instrument and the average surface roughness Ra was measured using Wyko NT1100. The analysis of variance (ANOVA) by using Design Expert software revealed that feed rate and depth of cut are the most significant factors on vibration meanwhile for average surface roughness, Ra, spindle speed is the most significant factor.
Effects of aging on the fundamental color chemistry of dark-cutting beef.
English, A R; Wills, K M; Harsh, B N; Mafi, G G; VanOverbeke, D L; Ramanathan, R
2016-09-01
The objective of the current study was to evaluate the effects of aging on myoglobin chemistry of dark-cutting beef. Ten USDA Choice (mean pH = 5.6; normal pH beef) and 10 no-roll dark cutter (mean pH = 6.4) strip loins were obtained from a commercial packing plant within 3 d of harvest. Loins were cut into 4 sections, vacuum packaged, randomly assigned to 0-, 21-, 42-, and 62-d aging at 2°C in the dark. Following aging, loin sections were cut into 2.5-cm-thick steaks and were used to determine bloom development, oxygen consumption (OC), metmyoglobin reducing activity (MRA), and lipid oxidation. Surface color readings were measured using a HunterLab Miniscan XE Plus spectrophotometer. A significant muscle type × aging time interaction resulted for OC ( < 0.001). Normal pH steaks declined more ( < 0.001) in OC during aging than dark-cutting beef. On d 0, dark-cutting beef had a greater OC ( < 0.001) than normal pH beef. There was a significant muscle type × oxygenation time × aging period interaction for L* values, deoxymyoglobin (DeoxyMb), and oxymyoglobin (OxyMb). When dark-cutting sections were aged for 62 d, both 0 and 60 min bloom development L* values were greater ( < 0.0001) than 0 min dark-cutting sections aged for 21 or 42 d. At all aging periods, normal pH beef had greater OxyMb content and lower DeoxyMb ( < 0.0001) during bloom development than dark-cutting beef. An aging period × muscle type interaction was significant for % overall reflectance ( = 0.0017) and absorbance ( = 0.0038). Dark cutting and normal pH beef loin sections aged for 62 d had greater reflectance ( < 0.0001) than 21 d. On d 0, dark-cutting beef had greater ( < 0.0001) MRA than normal pH beef. There were no significant ( = 0.14) differences in MRA between 42 and 62 d between dark-cutting and normal pH beef. Dark cutting steaks had lower thiobarbituric acid reactive substances values ( < 0.0001) than normal pH steaks. The results indicate that characterizing the myoglobin chemistry during aging will help to design strategies to improve appearance of high pH beef.
Villemain, Olivier; Kwiecinski, Wojciech; Bel, Alain; Robin, Justine; Bruneval, Patrick; Arnal, Bastien; Tanter, Mickael; Pernot, Mathieu; Messas, Emmanuel
2016-10-01
Basal chordae surgical section has been shown to be effective in reducing ischaemic mitral regurgitation (IMR). Achieving this section by non-invasive mean can considerably decrease the morbidity of this intervention on already infarcted myocardium. We investigated in vitro and in vivo the feasibility and safety of pulsed cavitational focused ultrasound (histotripsy) for non-invasive chordal cutting guided by real-time 3D echocardiography. Experiments were performed on 12 sheep hearts, 5 in vitro on explanted sheep hearts and 7 in vivo on beating sheep hearts. In vitro, the mitral valve (MV) apparatus including basal and marginal chordae was removed and fixed on a holder in a water tank. High-intensity ultrasound pulses were emitted from the therapeutic device (1-MHz focused transducer, pulses of 8 µs duration, peak negative pressure of 17 MPa, repetition frequency of 100 Hz), placed at a distance of 64 mm under 3D echocardiography guidance. In vivo, after sternotomy, the same therapeutic device was applied on the beating heart. We analysed MV coaptation and chordae by real-time 3D echocardiography before and after basal chordal cutting. After sacrifice, the MV apparatus were harvested for anatomical and histological post-mortem explorations to confirm the section of the chordae. In vitro, all chordae were completely cut after a mean procedure duration of 5.5 ± 2.5 min. The procedure duration was found to increase linearly with the chordae diameter. In vivo, the central basal chordae of the anterior leaflet were completely cut. The mean procedure duration was 20 ± 9 min (min = 14, max = 26). The sectioned chordae was visible on echocardiography, and MV coaptation remained normal with no significant mitral regurgitation. Anatomical and histological post-mortem explorations of the hearts confirmed the section of the chordae. Histotripsy guided by 3D echo achieved successfully to cut MV chordae in vitro and in vivo in beating heart. We hope that this technique will open the door in the near future to the non-invasive treatment of functional IMR. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
The Cut-Score Operating Function: A New Tool to Aid in Standard Setting
ERIC Educational Resources Information Center
Grabovsky, Irina; Wainer, Howard
2017-01-01
In this essay, we describe the construction and use of the Cut-Score Operating Function in aiding standard setting decisions. The Cut-Score Operating Function shows the relation between the cut-score chosen and the consequent error rate. It allows error rates to be defined by multiple loss functions and will show the behavior of each loss…
A Comparison of Cut Scores Using Multiple Standard Setting Methods.
ERIC Educational Resources Information Center
Impara, James C.; Plake, Barbara S.
This paper reports the results of using several alternative methods of setting cut scores. The methods used were: (1) a variation of the Angoff method (1971); (2) a variation of the borderline group method; and (3) an advanced impact method (G. Dillon, 1996). The results discussed are from studies undertaken to set the cut scores for fourth grade…
Wu, Yong-Jie; Huang, Xue-Lin; Chen, Qi-Zhu; Li, Xiao-Ju; Engelmann, Florent
2007-02-01
In this paper, we described the direct somatic embryogenesis from both immature cotyledon cuts and nucelli in the same mango cultivar (Mangifera indica L. var Zihua), studied the effect of growth conditions of embryogenic cultures (EMs) on cryopreservation and compared the cryopreservation response of EMs induced from these two different explants. Histological studies demonstrated that EMs derived from nucelli could be induced directly from epidermal cells of both sides of nucelli, whereas EMs derived from cotyledon cuts were induced only from epidermal cells of the adaxial side of the cotyledons. EMs from either nucelli or cotyledon cuts could be maintained in liquid medium or on solid medium and cryopreserved using a vitrification procedure. Success of cryopreservation of EMs depended on the dehydration treatment and the defined growth conditions during culture but not on their origins. When EMs were sampled during their exponential growth phase in liquid medium and dehydrated with PVS(3) solution for 5 min, survival of the EMs induced from cotyledon cuts and nucelli reached 77.7 and 80%, respectively, after cryopreservation in liquid nitrogen for 24 h. Furthermore, when dehydrated with PVS(3) solution for 30 min, all EMs induced from cotyledon cuts and 96.7% of EMs induced from nucelli could survive after cryopreservation. Cryopreservation did not affect the plant regeneration potential of EMs through somatic embryogenesis. The protocols of somatic embryogenesis and cryopreservation of mango EMs established in this study may offer potential ways to improve mango germplasm conservation and genetic improvement.
Effects of the closing speed of stapler jaws on bovine pancreases.
Chikamoto, Akira; Hashimoto, Daisuke; Ikuta, Yoshiaki; Tsuji, Akira; Abe, Shinya; Hayashi, Hiromitsu; Imai, Katsunori; Nitta, Hidetoshi; Ishiko, Takatoshi; Watanabe, Masayuki; Beppu, Toru; Baba, Hideo
2014-01-01
The division of the pancreatic parenchyma using a stapler is important in pancreatic surgery, especially for laparoscopic surgery. However, this procedure has not yet been standardized. We analyzed the effects of the closing speed of stapler jaws using bovine pancreases for each method. Furthermore, we assigned 10 min to the slow compression method, 5 min to the medium-fast compression method, and 30 s to the rapid compression (RC) method. The time allotted to holding (3 min) and dividing (30 s) was equal under each testing situation. We found that the RC method showed a high-pressure tolerance compared with the other two groups (rapid, 126 ± 49.0 mmHg; medium-fast, 55.5 ± 25.8 mmHg; slow, 45.0 ± 15.7 mmHg; p < 0.01), although the histological findings of the cut end were similar. The histological findings of the pancreatic capsule and parenchyma after the compression by staple jaws without firing also were similar. RC may provide an advantage as measured by pressure tolerance. A small series of distal pancreatectomy with a stapler that compares the speed of different stapler jaw closing times is required to prove the feasibility of these results after the confirmation of the advantages of the RC method under various settings.
Hydraulic Resistance of Vitreous Cutters: The Impact of Blade Design and Cut Rate.
Rossi, Tommaso; Querzoli, Giorgio; Angelini, Giampiero; Malvasi, Carlo; Rossi, Alessandro; Morini, Mario; Esposito, Graziana; Micera, Alessandra; di Luca, Natale Mario; Ripandelli, Guido
2016-07-01
To measure the hydraulic resistance (HR) of vitreous cutters equipped with a Regular guillotine Blade (RB) or double edge blade (DEB) at cut rates comprised between 0 and 12,000 cuts per minute (CPM) and compare it with vitreous fragment size. This was an in vitro experimental study; in vivo HR measure and vitreous sampling. HR, defined as aspiration pressure/flow rate, was measured in balanced salt solution (BSS; Alcon, Fort Worth, TX) (in vitro) and during pars plana vitrectomy of 20 consecutive patients aged 18 to 65, undergoing macular surgery. HR was recorded at increasing cut rates (500-6000 CPM for the RB and 500-12,000 CPM for the DEB; 5 mL/min flow). Vitreous samples were withdrawn and analyzed with Western and collagen type II and IX immunostaining to evaluate protein size. The main outcome measures were hydraulic resistance (mm Hg/ml/min [±SD]) and optic density for Western blot and immunostaining. RB and DEB showed identical HR in BSS between 0 and 3000 CPM. Above 3000 CPM, RB HR steadily increased, and was significantly higher than DEB HR. Vitreous HR was also similar for the two blades between 0 and 1500 CPM. Above 1500 CPM, RB offered a significantly higher resistance. Western blot and immunostaining of vitreous samples did not yield a significant difference in size, regardless of blade type and cut rate. DEB is more efficient, offering a lower HR than RB over 1500 CPM in human vitreous. There is no viscosity reduction as a function of cut-rate between 1500 and 12,000 CPM, as HR does not vary. Future vitreous cutters will benefit of a DEB; optimal cut rate needs to be defined, and the simple increase of cut rate does not provide benefits after a certain limit to be assessed.
Effectiveness of assisted and unassisted cough capacity in amyotrophic lateral sclerosis patients.
Sancho, Jesús; Servera, Emilio; Bañuls, Pilar; Marín, Julio
2017-11-01
Decreased cough capacity during a respiratory infection is one of the main causes of acute respiratory failure and hospitalisation in amyotrophic lateral sclerosis (ALS). To determine whether a respiratory measurement could identify the effectiveness of cough capacity in ALS during a respiratory infection. This was a prospective study of all ALS patients who were treated at a respiratory care unit due to a respiratory infection from 2012 to 2016. The effectiveness of unassisted and assisted coughing was evaluated and respiratory function tests were performed during the acute episode. Forty-eight ALS patients were enrolled, with only four having an effective unassisted cough. The variable which predicted unassisted cough effectiveness was peak cough flow (PCF) (OR 4499.27; 95%CI 3.60-3219086.19; p = 0.022) with a cut-off point of 2.77 L/s (166 L/min). For manually assisted coughing, the predictor of cough effectiveness was manually assisted PCF (cut-off point of 2.82-169 L/min) (OR 2198.602; 95% CI 3.750-1351691.42; p = 0.019). Mechanically assisted PCF (cut-off point of 2.95-177 L/min) was found to be the predictor of mechanically assisted coughing effectiveness (OR 23.40; 95% CI 2.11-258.96; p = 0.010). During a respiratory infection in ALS patients, the effectiveness of assisted and unassisted cough capacity depends on the PCF generated.
Gaibazzi, Nicola; Petrucci, Nicola; Ziacchi, Vigilio
2004-03-01
Previous work showed a strong inverse association between 1-min heart rate recovery (HRR) after exercising on a treadmill and all-cause mortality. The aim of this study was to determine whether the results could be replicated in a wide population of real-world exercise ECG candidates in our center, using a standard bicycle exercise test. Between 1991 and 1997, 1420 consecutive patients underwent ECG exercise testing performed according to our standard cycloergometer protocol. Three pre-specified cut-point values of 1-min HRR, derived from previous studies in the medical literature, were tested to see whether they could identify a higher-risk group for all-cause mortality; furthermore, we tested the possible association between 1-min HRR as a continuous variable and mortality using logistic regression. Both methods showed a lack of a statistically significant association between 1-min HRR and all-cause mortality. A weak trend toward an inverse association, although not statistically significant, could not be excluded. We could not validate the clear-cut results from some previous studies performed using the treadmill exercise test. The results in our study may only "not exclude" a mild inverse association between 1-min HRR measured after cycloergometer exercise testing and all-cause mortality. The 1-min HRR measured after cycloergometer exercise testing was not clinically useful as a prognostic marker.
Machinability of IPS Empress 2 framework ceramic.
Schmidt, C; Weigl, P
2000-01-01
Using ceramic materials for an automatic production of ceramic dentures by CAD/CAM is a challenge, because many technological, medical, and optical demands must be considered. The IPS Empress 2 framework ceramic meets most of them. This study shows the possibilities for machining this ceramic with economical parameters. The long life-time requirement for ceramic dentures requires a ductile machined surface to avoid the well-known subsurface damages of brittle materials caused by machining. Slow and rapid damage propagation begins at break outs and cracks, and limits life-time significantly. Therefore, ductile machined surfaces are an important demand for machine dental ceramics. The machining tests were performed with various parameters such as tool grain size and feed speed. Denture ceramics were machined by jig grinding on a 5-axis CNC milling machine (Maho HGF 500) with a high-speed spindle up to 120,000 rpm. The results of the wear test indicate low tool wear. With one tool, you can machine eight occlusal surfaces including roughing and finishing. One occlusal surface takes about 60 min machining time. Recommended parameters for roughing are middle diamond grain size (D107), cutting speed v(c) = 4.7 m/s, feed speed v(ft) = 1000 mm/min, depth of cut a(e) = 0.06 mm, width of contact a(p) = 0.8 mm, and for finishing ultra fine diamond grain size (D46), cutting speed v(c) = 4.7 m/s, feed speed v(ft) = 100 mm/min, depth of cut a(e) = 0.02 mm, width of contact a(p) = 0.8 mm. The results of the machining tests give a reference for using IPS Empress(R) 2 framework ceramic in CAD/CAM systems. Copyright 2000 John Wiley & Sons, Inc.
Exploiting Elementary Landscapes for TSP, Vehicle Routing and Scheduling
2015-09-03
Traveling Salesman Problem (TSP) and Graph Coloring are elementary. Problems such as MAX-kSAT are a superposition of k elementary landscapes. This...search space. Problems such as the Traveling Salesman Problem (TSP), Graph Coloring, the Frequency Assignment Problem , as well as Min-Cut and Max-Cut...echoing our earlier esults on the Traveling Salesman Problem . Using two locally optimal solutions as “parent” solutions, we have developed a
High-speed fiber laser cutting of thick stainless steel for dismantling tasks
NASA Astrophysics Data System (ADS)
Shin, Jae Sung; Oh, Seong Yong; Park, Hyunmin; Chung, Chin-Man; Seon, Sangwoo; Kim, Taek-Soo; Lee, Lim; Choi, Byung-Seon; Moon, Jei-Kwon
2017-09-01
A high-speed fiber laser cutting technology of thick steels for dismantling tasks was achieved using a 6-kW fiber laser system. At first, a new cutting head for efficient cutting of thick steels was developed, which was composed by a collimator with a focal length of 160 mm and mirror-type focusing objects with a long focal length of 600 mm. The long focal length of the focusing object made it possible for the beam size to be small through the thick cutting material and the cutting efficiency was expected to increase compared with the short focal length. In addition, folding the beam facilitated the compact cutting head with a size of 160 mm (width) × 80 mm (height) × 640 mm (length) and a weight of 6.9 kg. In the cutting experiment, the laser beam was delivered to the cutting head by a 25-m long process fiber with a core diameter of 100 μm. The cutting performances were studied against the thicknesses of stainless steel plates. A maximum cutting speed of 72 mm/min was obtained for the 60-mm thick stainless steel plate cutting and the cut specimen showed an excellent kerf shape and a narrow kerf width. To the best of our knowledge, this cutting speed was higher than other previously reported results when cutting with a 6-kW laser power.
Declercq, Peter; Gijsen, Matthias; Meijers, Björn; Schetz, Marie; Nijs, Stefaan; D'Hoore, André; Wauters, Joost; Spriet, Isabel
2018-05-07
Formulae estimating glomerular filtration rate (GFR) are frequently used to guide drug dosing. The objectives of this prospective single-center study were to evaluate agreement between these equations and measured creatinine clearance (CrCl) in non-critically ill surgery patients with normal kidney function and augmented renal clearance (ARC, CrCl ≥ 130 mL/min/1.73 m²), to determine predictors for disagreement, define a GFR estimator cut-off value identifying ARC and determine the ARC prevalence and duration in non-critically ill surgical patients. Hospitalized adult non-critically ill abdominal and trauma surgery patients were eligible for inclusion. Measured CrCl based on an 8-hour urinary collection (CrCl 8h ) was used as the primary method for determining kidney function. Agreement between equations and measured CrCl 8h was assessed in terms of precision, defined as a bias within ±10 mL/min/1.73 m². Predictors for disagreement were identified for the most precise estimator using an ordinal logistic regression model with negative bias, agreement and positive bias as outcome variables. A receiver operating characteristic (ROC) analysis was performed to identify an estimator cut-off predicting ARC, which was subsequently applied for the daily proportion of patients displaying ARC and ARC duration. During the study period (14/11/2013 - 13/05/2014), in 232 adult non-critically ill abdominal and trauma surgery patients, all estimators tend to underestimate CrCl 8h (mean bias ranging from 17 to 22 mL/min/1.73 m²), especially in patients displaying ARC (mean bias ranging from 44 to 56 mL/min/1.73 m²). eGFR CKD-EPI performed the best. Younger age and low ASA score independently predicted underestimation of CrCl 8h . Three different eGFR CKD-EPI cut-offs with decreasing sensitivity and increasing specificity (84, 95 and 112 mL/min/1.73 m²) identified, respectively, 65%, 44% and 14% patients displaying ARC. The median ARC duration was 4, 4 and 3 days, respectively. In surgical patients, eGFR frequently underestimates measured CrCl, especially in young patients with low ASA score. eGFR cut-offs predicting ARC were identified. © 2018 John Wiley & Sons Ltd.
Quantitative assessment of the enamel machinability in tooth preparation with dental diamond burs.
Song, Xiao-Fei; Jin, Chen-Xin; Yin, Ling
2015-01-01
Enamel cutting using dental handpieces is a critical process in tooth preparation for dental restorations and treatment but the machinability of enamel is poorly understood. This paper reports on the first quantitative assessment of the enamel machinability using computer-assisted numerical control, high-speed data acquisition, and force sensing systems. The enamel machinability in terms of cutting forces, force ratio, cutting torque, cutting speed and specific cutting energy were characterized in relation to enamel surface orientation, specific material removal rate and diamond bur grit size. The results show that enamel surface orientation, specific material removal rate and diamond bur grit size critically affected the enamel cutting capability. Cutting buccal/lingual surfaces resulted in significantly higher tangential and normal forces, torques and specific energy (p<0.05) but lower cutting speeds than occlusal surfaces (p<0.05). Increasing material removal rate for high cutting efficiencies using coarse burs yielded remarkable rises in cutting forces and torque (p<0.05) but significant reductions in cutting speed and specific cutting energy (p<0.05). In particular, great variations in cutting forces, torques and specific energy were observed at the specific material removal rate of 3mm(3)/min/mm using coarse burs, indicating the cutting limit. This work provides fundamental data and the scientific understanding of the enamel machinability for clinical dental practice. Copyright © 2014 Elsevier Ltd. All rights reserved.
Castle, Toen; Sussman, Daniel M.; Tanis, Michael; Kamien, Randall D.
2016-01-01
Kirigami uses bending, folding, cutting, and pasting to create complex three-dimensional (3D) structures from a flat sheet. In the case of lattice kirigami, this cutting and rejoining introduces defects into an underlying 2D lattice in the form of points of nonzero Gaussian curvature. A set of simple rules was previously used to generate a wide variety of stepped structures; we now pare back these rules to their minimum. This allows us to describe a set of techniques that unify a wide variety of cut-and-paste actions under the rubric of lattice kirigami, including adding new material and rejoining material across arbitrary cuts in the sheet. We also explore the use of more complex lattices and the different structures that consequently arise. Regardless of the choice of lattice, creating complex structures may require multiple overlapping kirigami cuts, where subsequent cuts are not performed on a locally flat lattice. Our additive kirigami method describes such cuts, providing a simple methodology and a set of techniques to build a huge variety of complex 3D shapes. PMID:27679822
Castle, Toen; Sussman, Daniel M; Tanis, Michael; Kamien, Randall D
2016-09-01
Kirigami uses bending, folding, cutting, and pasting to create complex three-dimensional (3D) structures from a flat sheet. In the case of lattice kirigami, this cutting and rejoining introduces defects into an underlying 2D lattice in the form of points of nonzero Gaussian curvature. A set of simple rules was previously used to generate a wide variety of stepped structures; we now pare back these rules to their minimum. This allows us to describe a set of techniques that unify a wide variety of cut-and-paste actions under the rubric of lattice kirigami, including adding new material and rejoining material across arbitrary cuts in the sheet. We also explore the use of more complex lattices and the different structures that consequently arise. Regardless of the choice of lattice, creating complex structures may require multiple overlapping kirigami cuts, where subsequent cuts are not performed on a locally flat lattice. Our additive kirigami method describes such cuts, providing a simple methodology and a set of techniques to build a huge variety of complex 3D shapes.
ERIC Educational Resources Information Center
Shulruf, Boaz; Turner, Rolf; Poole, Phillippa; Wilkinson, Tim
2013-01-01
The decision to pass or fail a medical student is a "high stakes" one. The aim of this study is to introduce and demonstrate the feasibility and practicality of a new objective standard-setting method for determining the pass/fail cut-off score from borderline grades. Three methods for setting up pass/fail cut-off scores were compared: the…
Orthogonal cutting of cancellous bone with application to the harvesting of bone autograft.
Malak, Sharif F F; Anderson, Iain A
2008-07-01
Autogenous bone graft harvesting results in cell death within the graft and trauma at the donor site. The latter can be mitigated by using minimally invasive tools and techniques, while cell morbidity may be reduced by improving cutter design and cutting parameters. We have performed orthogonal cutting experiments on bovine cancellous bone samples, to gain a basic understanding of the cutting mechanism and to determine design guidelines for tooling. Measurements were performed at cutting speeds from 11.2 to 5000 mm/min, with tool rake angles of 23 degrees, 45 degrees and 60 degrees, and depths of cut in the range of 0.1-3.0 mm. Horizontal and vertical cutting forces were measured, and the chip formation process video recorded. Continuous chip formation was observed for rake angles of 45 degrees and 60 degrees , and depths of cut greater than 0.8 mm. Chip formation for depths of cut greater than 1.0 mm was accompanied by bone marrow extruding out of the free surfaces and away from the rake face. Specific cutting energies decreased with increasing rake angle, increasing depth of cut and increasing cutting speed. Our orthogonal cutting experiments showed that a rake angle of 60 degrees and a depth of cut of 1mm, will avoid excessive fragmentation, keep specific cutting energy low and promote bone marrow extrusion, which may be beneficial for cell survival. We demonstrate how drill bit clearance angle and feed rate can be calculated facilitating a 1mm depth of cut.
NASA Astrophysics Data System (ADS)
Lawal, S. A.; Choudhury, I. A.; Nukman, Y.
2015-01-01
The understanding of cutting fluids performance in turning process is very important in order to improve the efficiency of the process. This efficiency can be determined based on certain process parameters such as flank wear, cutting forces developed, temperature developed at the tool chip interface, surface roughness on the work piece, etc. In this study, the objective is to determine the influence of cutting fluids on flank wear during turning of AISI 4340 with coated carbide inserts. The performances of three types of cutting fluids were compared using Taguchi experimental method. The results show that palm kernel oil based cutting fluids performed better than the other two cutting fluids in reducing flank wear. Mathematical models for cutting parameters such as cutting speed, feed rate, depth of cut and cutting fluids were obtained from regression analysis using MINITAB 14 software to predict flank wear. Experiments were conducted based on the optimized values to validate the regression equations for flank wear and 5.82 % error was obtained. The optimal cutting parameters for the flank wear using S/N ratio were 160 m/min of cutting speed (level 1), 0.18 mm/rev of feed (level 1), 1.75 mm of depth of cut (level 2) and 2.97 mm2/s palm kernel oil based cutting fluid (level 3). ANOVA shows cutting speed of 85.36 %; and feed rate 4.81 %) as significant factors.
Min-Cut Based Segmentation of Airborne LIDAR Point Clouds
NASA Astrophysics Data System (ADS)
Ural, S.; Shan, J.
2012-07-01
Introducing an organization to the unstructured point cloud before extracting information from airborne lidar data is common in many applications. Aggregating the points with similar features into segments in 3-D which comply with the nature of actual objects is affected by the neighborhood, scale, features and noise among other aspects. In this study, we present a min-cut based method for segmenting the point cloud. We first assess the neighborhood of each point in 3-D by investigating the local geometric and statistical properties of the candidates. Neighborhood selection is essential since point features are calculated within their local neighborhood. Following neighborhood determination, we calculate point features and determine the clusters in the feature space. We adapt a graph representation from image processing which is especially used in pixel labeling problems and establish it for the unstructured 3-D point clouds. The edges of the graph that are connecting the points with each other and nodes representing feature clusters hold the smoothness costs in the spatial domain and data costs in the feature domain. Smoothness costs ensure spatial coherence, while data costs control the consistency with the representative feature clusters. This graph representation formalizes the segmentation task as an energy minimization problem. It allows the implementation of an approximate solution by min-cuts for a global minimum of this NP hard minimization problem in low order polynomial time. We test our method with airborne lidar point cloud acquired with maximum planned post spacing of 1.4 m and a vertical accuracy 10.5 cm as RMSE. We present the effects of neighborhood and feature determination in the segmentation results and assess the accuracy and efficiency of the implemented min-cut algorithm as well as its sensitivity to the parameters of the smoothness and data cost functions. We find that smoothness cost that only considers simple distance parameter does not strongly conform to the natural structure of the points. Including shape information within the energy function by assigning costs based on the local properties may help to achieve a better representation for segmentation.
Quantification of Internal Filtration in Hollow Fiber Hemodialyzers with Medium Cut-Off Membrane.
Lorenzin, Anna; Neri, Mauro; Lupi, Andrea; Todesco, Martina; Santimaria, Monica; Alghisi, Alberta; Brendolan, Alessandra; Ronco, Claudio
2018-06-08
Inadequate removal of molecules between 5 and 50 KDa may cause long-term complication in chronic hemodialysis. Medium cut-off (MCO) is a new class of membranes with enhanced sieving properties and negligible albumin loss. MCO membrane makes it possible to perform expanded hemodialysis (HDx), a technique based on high internal filtration (IF).The present study is designed to quantify IF in 2 MCO dialyzers (Theranova 400 and 500, Baxter, Deerfield, USA) using a nuclear imaging technique previously validated. Blood and dialysate compartment pressure drop along with transmembrane pressure; they were measured in a closed in vitro circuit with human blood (blood flow [QB] = 300 and 400 mL/min; dialysate flow 500 mL/min; net ultrafiltration rate 0 mL/min). A non-diffusible marker molecule (albumin macro-aggregates labeled with 99Tc metastable) was injected in the blood compartment and nuclear emission was recorded by a gamma camera. Relative variations in the concentration of the marker molecule along the length of the filter were used to calculate local cross filtration. Based on marker concentration profiles, IF was estimated. For Theranova 400, IF were 29.7 and 41.6 mL/min for QB of 300 and 400 mL/min. For Theranova 500, IF were 31.6 and 53.1 mL/min for QB of 300 and 400 mL/min respectively. MCO membrane provides significant amounts of IF due to the particular combination between hydraulic permeability of the membrane and reduced inner diameter of the fibers. High IF combined with enhanced sieving profile of MCO membrane leads to improved removal of a wider spectrum of uremia retention molecules in HDx, without requiring complex equipment. © 2018 S. Karger AG, Basel.
Green Turning of FCD 700 Ductile Cast Iron Using Coated Carbide Tool
NASA Astrophysics Data System (ADS)
Rodzi, Mohd Nor Azmi Mohd; Ghani, Jaharah A.; Eghawail, A. M.; Othman, Kamal; Rahman, Mohd. Nizam Ab.; Haron, Che Hassan Che
2010-10-01
This paper presents the performance of carbide coated cutting insert in turning FCD700 ductile cast iron in various dry machining conditions (without air, using air and chilled air). The turning parameters studied were, cutting speed of 120 m/min., feed rate of 0.15 mm/rev-0.4 mm/rev, and depth of cut of 0.6 mm-1.0 mm. The results show that the tool life was significantly controlled by the type of air coolant used, whereas the cutting force and surface roughness were not influenced by these coolants. Chilled air was found to be significantly improved the tool life by about 30% and 40% respectively when compared with normal air and without air conditions. The wear mechanism was predominantly controlled by the flank and crater wears on the flank and rake faces respectively. Due to the low cutting speed used in the experiment, both flank and crater wears were uniformly formed along the cutting edge and no catastrophic failure was observed under the scanning electron microscope (SEM).
An Investigation of Undefined Cut Scores with the Hofstee Standard-Setting Method
ERIC Educational Resources Information Center
Wyse, Adam E.; Babcock, Ben
2017-01-01
This article provides an overview of the Hofstee standard-setting method and illustrates several situations where the Hofstee method will produce undefined cut scores. The situations where the cut scores will be undefined involve cases where the line segment derived from the Hofstee ratings does not intersect the score distribution curve based on…
SIGPI. Fault Tree Cut Set System Performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patenaude, C.J.
1992-01-13
SIGPI computes the probabilistic performance of complex systems by combining cut set or other binary product data with probability information on each basic event. SIGPI is designed to work with either coherent systems, where the system fails when certain combinations of components fail, or noncoherent systems, where at least one cut set occurs only if at least one component of the system is operating properly. The program can handle conditionally independent components, dependent components, or a combination of component types and has been used to evaluate responses to environmental threats and seismic events. The three data types that can bemore » input are cut set data in disjoint normal form, basic component probabilities for independent basic components, and mean and covariance data for statistically dependent basic components.« less
SIGPI. Fault Tree Cut Set System Performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patenaude, C.J.
1992-01-14
SIGPI computes the probabilistic performance of complex systems by combining cut set or other binary product data with probability information on each basic event. SIGPI is designed to work with either coherent systems, where the system fails when certain combinations of components fail, or noncoherent systems, where at least one cut set occurs only if at least one component of the system is operating properly. The program can handle conditionally independent components, dependent components, or a combination of component types and has been used to evaluate responses to environmental threats and seismic events. The three data types that can bemore » input are cut set data in disjoint normal form, basic component probabilities for independent basic components, and mean and covariance data for statistically dependent basic components.« less
Rashno, Abdolreza; Nazari, Behzad; Koozekanani, Dara D.; Drayna, Paul M.; Sadri, Saeed; Rabbani, Hossein
2017-01-01
A fully-automated method based on graph shortest path, graph cut and neutrosophic (NS) sets is presented for fluid segmentation in OCT volumes for exudative age related macular degeneration (EAMD) subjects. The proposed method includes three main steps: 1) The inner limiting membrane (ILM) and the retinal pigment epithelium (RPE) layers are segmented using proposed methods based on graph shortest path in NS domain. A flattened RPE boundary is calculated such that all three types of fluid regions, intra-retinal, sub-retinal and sub-RPE, are located above it. 2) Seed points for fluid (object) and tissue (background) are initialized for graph cut by the proposed automated method. 3) A new cost function is proposed in kernel space, and is minimized with max-flow/min-cut algorithms, leading to a binary segmentation. Important properties of the proposed steps are proven and quantitative performance of each step is analyzed separately. The proposed method is evaluated using a publicly available dataset referred as Optima and a local dataset from the UMN clinic. For fluid segmentation in 2D individual slices, the proposed method outperforms the previously proposed methods by 18%, 21% with respect to the dice coefficient and sensitivity, respectively, on the Optima dataset, and by 16%, 11% and 12% with respect to the dice coefficient, sensitivity and precision, respectively, on the local UMN dataset. Finally, for 3D fluid volume segmentation, the proposed method achieves true positive rate (TPR) and false positive rate (FPR) of 90% and 0.74%, respectively, with a correlation of 95% between automated and expert manual segmentations using linear regression analysis. PMID:29059257
Reliability and validity of the PHQ-9 for screening late-life depression in Chinese primary care.
Chen, Shulin; Chiu, Helen; Xu, Baihua; Ma, Yan; Jin, Tao; Wu, Manhua; Conwell, Yeates
2010-11-01
The aim of this study was to examine the reliability and validation of the 9-item Patient Health Questionnaire (PHQ-9) for late-life depression in Chinese primary care. In the primary care clinics (PCCs) of Hangzhou city, we recruited 364 older patients (aged ≥ 60) for the PHQ-9 screening. Then 77 of them were further interviewed with Structured Clinical Interview for DSM Disorders (SCID) for the diagnosis of major depression in late life. Statistic strategies for the feasibility, reliability, validity, and receiver operating characteristic curve were performed. The mean administration time was 7.5 min, and the Cronbach's α was 0.91. The optimal cut-off score of PHQ-9 ≥ 9 revealed a sensitivity of 0.86, specificity of 0.77, and positive likelihood ratio of 5.73. The area under the curve (AUC) in this study was 0.92 (SD = 0.02, 95% CI 0.88-0.96). The PHQ-2 also revealed good sensitivity (0.84) and specificity (0.90) at the cut-off point ≥ 3. The PHQ-9 performs well and has acceptable psychometric properties for screening of patients with late-life depression in Chinese primary care settings.
NASA Astrophysics Data System (ADS)
M, Vasu; Shivananda Nayaka, H.
2018-06-01
In this experimental work dry turning process carried out on EN47 spring steel with coated tungsten carbide tool insert with 0.8 mm nose radius are optimized by using statistical technique. Experiments were conducted at three different cutting speeds (625, 796 and 1250 rpm) with three different feed rates (0.046, 0.062 and 0.093 mm/rev) and depth of cuts (0.2, 0.3 and 0.4 mm). Experiments are conducted based on full factorial design (FFD) 33 three factors and three levels. Analysis of variance is used to identify significant factor for each output response. The result reveals that feed rate is the most significant factor influencing on cutting force followed by depth of cut and cutting speed having less significance. Optimum machining condition for cutting force obtained from the statistical technique. Tool wear measurements are performed with optimum condition of Vc = 796 rpm, ap = 0.2 mm, f = 0.046 mm/rev. The minimum tool wear observed as 0.086 mm with 5 min machining. Analysis of tool wear was done by confocal microscope it was observed that tool wear increases with increasing cutting time.
NASA Astrophysics Data System (ADS)
Zhang, Jie; Tao, Sha; Wang, Brian; Zhao, Jay
2017-02-01
In this paper, micro-processing of three kinds of super-hard materials of poly-crystal diamond (PCD)/tungsten-carbide (WC), CVD-diamond and cubic boron nitride (CNB) has been systematically studied using nanosecond laser (532nm and 355nm), and ultrafast laser (532nm and 515nm). Our purpose is to investigate a full laser micro-cutting solution to achieve a ready-to-use cutting tool insert (CTI). The results show a clean cut with little burns and recasting at edge. The cutting speed of 2-10mm/min depending on thickness was obtained. The laser ablation process was also studied by varying laser parameters (wavelength, pulse width, pulse energy, repetition rate) and tool path to improve cutting speed. Also, studies on material removal efficiency (MRE) of PCD/WC with 355nm-ns and 515nm-fs laser as a function of laser fluence show that 355nm-ns laser is able to achieve higher MRE for PCD and WC. Thus, ultrafast laser is not necessarily used for superhard material cutting. Instead, post-polishing with ultrafast laser can be used to clean cutting surface and improve smoothness.
Suggestions for getting more forestry in the logging plan.
Robert H. Ruth; Roy R. Silen
1950-01-01
The staggered-setting system of clear-cutting is fast becoming prevailing practice in the Douglas-fir region. The trend is away from large, continuous clear cuts to clear-cutting smaller units of timber of less than 80 acres. These are called staggered settings because the surrounding stand is left uncut to provide seed and serve as a firebreak. Major aims of this...
ERIC Educational Resources Information Center
Giraud, Gerald T.; Buckendahl, Chad; Lucas, Mike
This study examined the efficacy of teacher judgment in the process of setting mastery scores (cut scores) for fourth-grade mathematics in local school districts in Nebraska in terms of agreement between teacher classification of students and classification by the cut score obtained by this classification. The study also examined cut scores in…
Adopting Cut Scores: Post-Standard-Setting Panel Considerations for Decision Makers
ERIC Educational Resources Information Center
Geisinger, Kurt F.; McCormick, Carina M.
2010-01-01
Standard-setting studies utilizing procedures such as the Bookmark or Angoff methods are just one component of the complete standard-setting process. Decision makers ultimately must determine what they believe to be the most appropriate standard or cut score to use, employing the input of the standard-setting panelists as one piece of information…
Maxwell Strata and Cut Locus in the Sub-Riemannian Problem on the Engel Group
NASA Astrophysics Data System (ADS)
Ardentov, Andrei A.; Sachkov, Yuri L.
2017-12-01
We consider the nilpotent left-invariant sub-Riemannian structure on the Engel group. This structure gives a fundamental local approximation of a generic rank 2 sub-Riemannian structure on a 4-manifold near a generic point (in particular, of the kinematic models of a car with a trailer). On the other hand, this is the simplest sub-Riemannian structure of step three. We describe the global structure of the cut locus (the set of points where geodesics lose their global optimality), the Maxwell set (the set of points that admit more than one minimizer), and the intersection of the cut locus with the caustic (the set of conjugate points along all geodesics). The group of symmetries of the cut locus is described: it is generated by a one-parameter group of dilations R+ and a discrete group of reflections Z2 × Z2 × Z2. The cut locus admits a stratification with 6 three-dimensional strata, 12 two-dimensional strata, and 2 one-dimensional strata. Three-dimensional strata of the cut locus are Maxwell strata of multiplicity 2 (for each point there are 2 minimizers). Two-dimensional strata of the cut locus consist of conjugate points. Finally, one-dimensional strata are Maxwell strata of infinite multiplicity, they consist of conjugate points as well. Projections of sub-Riemannian geodesics to the 2-dimensional plane of the distribution are Euler elasticae. For each point of the cut locus, we describe the Euler elasticae corresponding to minimizers coming to this point. Finally, we describe the structure of the optimal synthesis, i. e., the set of minimizers for each terminal point in the Engel group.
Li, Fang; Wang, Qian; Yao, Gui Hua; Zhang, Peng Fei; Ge, Zhi Ming; Zhang, Mei; Zhang, Yun
2008-01-01
Real-time three-dimensional (3D) echocardiography (RT-3DE) has emerged as a new technique in measuring left atrial and ventricular volume. However, the impact of cutting planes of RT-3DE on the accuracy of volume measurement in patients with a normal or enlarged heart is still unknown. We enrolled 30 normal subjects (control group) and 30 patients with heart failure (patient group). RT-3DE was performed to measure maximal volume of the left atrium (LAVmax) and left ventricular end-diastole volume (LVEDV) with 2-, 4-, 8- and 16-cutting planes, compared with cardiac magnetic resonance imaging (CMRI). In both groups, LAVmax by RT-3DE using 2- and 4-cutting planes was significantly underestimated (mean difference: -10.4 +/- 16.6 mL, p = 0.001 and -8.8 +/- 14.2 mL, p = 0.002 in the control group and -13.4 +/- 19.6 mL, p = 0.001 and -11.2 +/- 17.5 mL, p = 0.001 in the patient group, respectively). These differences became nonsignificant when 8- and 16-cutting planes were adopted (mean difference: -2.1 +/- 7.6 mL and -1.9 +/- 7.4 mL in the control group and -2.7 +/- 8.4 mL and -2.2 +/- 8.3 mL in the patient group, respectively). The agreement for LVEDV was acceptable when 4- or more cutting planes were used in the control group and when 8- or 16-cutting planes were used in the patient group. The time expense for data analysis of LAVmax with 8-image planes was only 7 +/- 4 min in the control group and 6 +/- 5 min in the patient group, almost halving that of the 16-image planes. Similarly, 4- and 8-cutting planes were required for an accurate measurement of LVEDV in the control and patient groups, respectively. In conclusion, RT-3DE with 8-cutting planes is both accurate and timesaving for measurement of LAVmax and LVEDV in patients with normal or enlarged left atria and ventricles.
Hand-arm vibration in orthopaedic surgery: a neglected risk.
Mahmood, F; Ferguson, K B; Clarke, J; Hill, K; Macdonald, E B; Macdonald, D J M
2017-12-30
Hand-arm vibration syndrome is an occupational disease caused by exposure to hand-arm transmitted vibration. The Health and Safety Executive has set limits for vibration exposure, including an exposure action value (EAV), where steps should be taken to reduce exposure, and an exposure limit value (ELV), beyond which vibrating equipment must not be used for the rest of the working day. To measure hand-arm transmitted vibration among orthopaedic surgeons, who routinely use hand-operated saws. We undertook a cadaveric study measuring vibration associated with a tibial cut using battery-operated saws. Three surgeons undertook three tibial cuts each on cadaveric tibiae. Measurements were taken using a frequency-weighted root mean square acceleration, with the vibration total value calculated as the root of the sums squared in each of the three axes. A mean (SD) vibration magnitude of 1 (0.2) m/s2 in the X-axis, 10.3 (1.9) m/s2 in the Y-axis and 4.2 (1.3) m/s2 in the Z-axis was observed. The weighted root mean squared magnitude of vibration was 11.3 (1.7) m/s2. These results suggest an EAV of 23 min and ELV of 1 h 33 min using this equipment. Our results demonstrate that use of a battery-operated sagittal saw can transmit levels of hand-arm vibration approaching the EAV or ELV through prolonged use. Further study is necessary to quantify this risk and establish whether surveillance is necessary for orthopaedic surgeons. © The Author 2017. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com
MIRAP, microcomputer reliability analysis program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jehee, J.N.T.
1989-01-01
A program for a microcomputer is outlined that can determine minimal cut sets from a specified fault tree logic. The speed and memory limitations of the microcomputers on which the program is implemented (Atari ST and IBM) are addressed by reducing the fault tree's size and by storing the cut set data on disk. Extensive well proven fault tree restructuring techniques, such as the identification of sibling events and of independent gate events, reduces the fault tree's size but does not alter its logic. New methods are used for the Boolean reduction of the fault tree logic. Special criteria formore » combining events in the 'AND' and 'OR' logic avoid the creation of many subsuming cut sets which all would cancel out due to existing cut sets. Figures and tables illustrates these methods. 4 refs., 5 tabs.« less
Belen, Erdal; Ozal, Ender; Bayyigit, Akif; Gunaydın, Senay; Helvacı, Aysen
Myocardial injury after non-cardiac surgery (MINS) is closely related to increased cardiovascular mortality. To evaluate the relationship between MINS and interarm systolic blood pressure difference (IASBPD), which has previously been shown to correlate with the frequency of cardiovascular events and arterial arteriosclerotic processes. This observational, single-centre cohort study included 240 consecutive noncardiac surgery patients aged ≥ 45 years. Simultaneous blood pressure recordings were taken preoperatively and IASBPD was calculated. Patients' electrocardiography recordings and high sensitivity cardiac troponin T (hscTnT) levels were obtained for a period of three days postoperatively. Postoperatively, 27 (11.3%) patients were found to have MINS when hscTnT ≥ 14 ng/L was taken as a cut-off value. IASBPD > 10 mm Hg was found in 44 (18.3%) patients. When IASBPD was accepted to be a continuous variable, there was a higher IASBPD value in the MINS group (9.4 ± 5.0 vs. 4.5 ± 3.8, p < 0.000). When patients were grouped as those having IASBPD > 10 mm Hg and those not, exaggerate IASBPD was found to be more frequent in patients developing MINS (16 [59.3%] vs. 28 [13.1%], respectively, p < 0.000). Multiple logistic regression analysis found IASBPD > 10 mm Hg to be independently associated with the development of MINS (OR: 30.82; CI: 9.14-103.98; p < 0.000). Receiver operating char-acteristic curve analysis showed that the optimal IASBPD cut-off value for predicting MINS was 11.5 mm Hg, with a sensitivity of 61.0% and specificity of 89.1% (AUC = 0.79; 95% CI 0.71-0.87). Increased IASBPD is closely related to development of MINS. The preoperative measurement of blood pressure from both arms may be an important and easy to use clinical tool in determining cardiovascular risk.
A high performance sensor for triaxial cutting force measurement in turning.
Zhao, You; Zhao, Yulong; Liang, Songbo; Zhou, Guanwu
2015-04-03
This paper presents a high performance triaxial cutting force sensor with excellent accuracy, favorable natural frequency and acceptable cross-interference for high speed turning process. Octagonal ring is selected as sensitive element of the designed sensor, which is drawn inspiration from ring theory. A novel structure of two mutual-perpendicular octagonal rings is proposed and three Wheatstone full bridge circuits are specially organized in order to obtain triaxial cutting force components and restrain cross-interference. Firstly, the newly developed sensor is tested in static calibration; test results indicate that the sensor possesses outstanding accuracy in the range of 0.38%-0.83%. Secondly, impacting modal tests are conducted to identify the natural frequencies of the sensor in triaxial directions (i.e., 1147 Hz, 1122 Hz and 2035 Hz), which implies that the devised sensor can be used for cutting force measurement in a high speed lathe when the spindle speed does not exceed 17,205 rev/min in continuous cutting condition. Finally, an application of the sensor in turning process is operated to show its performance for real-time cutting force measurement; the measured cutting forces demonstrate a good accordance with the variation of cutting parameters. Thus, the developed sensor possesses perfect properties and it gains great potential for real-time cutting force measurement in turning.
A High Performance Sensor for Triaxial Cutting Force Measurement in Turning
Zhao, You; Zhao, Yulong; Liang, Songbo; Zhou, Guanwu
2015-01-01
This paper presents a high performance triaxial cutting force sensor with excellent accuracy, favorable natural frequency and acceptable cross-interference for high speed turning process. Octagonal ring is selected as sensitive element of the designed sensor, which is drawn inspiration from ring theory. A novel structure of two mutual-perpendicular octagonal rings is proposed and three Wheatstone full bridge circuits are specially organized in order to obtain triaxial cutting force components and restrain cross-interference. Firstly, the newly developed sensor is tested in static calibration; test results indicate that the sensor possesses outstanding accuracy in the range of 0.38%–0.83%. Secondly, impacting modal tests are conducted to identify the natural frequencies of the sensor in triaxial directions (i.e., 1147 Hz, 1122 Hz and 2035 Hz), which implies that the devised sensor can be used for cutting force measurement in a high speed lathe when the spindle speed does not exceed 17,205 rev/min in continuous cutting condition. Finally, an application of the sensor in turning process is operated to show its performance for real-time cutting force measurement; the measured cutting forces demonstrate a good accordance with the variation of cutting parameters. Thus, the developed sensor possesses perfect properties and it gains great potential for real-time cutting force measurement in turning. PMID:25855035
Making the Cut: Lattice Kirigami Rules
NASA Astrophysics Data System (ADS)
Castle, Toen; Cho, Yigil; Gong, Xingting; Jung, Euiyeon; Sussman, Daniel M.; Yang, Shu; Kamien, Randall D.
2014-12-01
In this Letter we explore and develop a simple set of rules that apply to cutting, pasting, and folding honeycomb lattices. We consider origami-like structures that are extrinsically flat away from zero-dimensional sources of Gaussian curvature and one-dimensional sources of mean curvature, and our cutting and pasting rules maintain the intrinsic bond lengths on both the lattice and its dual lattice. We find that a small set of rules is allowed providing a framework for exploring and building kirigami—folding, cutting, and pasting the edges of paper.
Liver vessels segmentation using a hybrid geometrical moments/graph cuts method
Esneault, Simon; Lafon, Cyril; Dillenseger, Jean-Louis
2010-01-01
This paper describes a fast and fully-automatic method for liver vessel segmentation on CT scan pre-operative images. The basis of this method is the introduction of a 3-D geometrical moment-based detector of cylindrical shapes within the min-cut/max-flow energy minimization framework. This method represents an original way to introduce a data term as a constraint into the widely used Boykov’s graph cuts algorithm and hence, to automate the segmentation. The method is evaluated and compared with others on a synthetic dataset. Finally, the relevancy of our method regarding the planning of a -necessarily accurate- percutaneous high intensity focused ultrasound surgical operation is demonstrated with some examples. PMID:19783500
Tanisaka, Yuki; Ryozawa, Shomei; Kobayashi, Masanori; Harada, Maiko; Kobatake, Tsutomu; Omiya, Kumiko; Iwano, Hirotoshi; Arai, Shin; Nonaka, Kouichi; Mashimo, Yumi
2018-02-01
Covered self-expandable metallic stents (CSEMS) may provide palliative drainage for unresectable distal malignant biliary strictures. Laser-cut CSEMS allows easy positioning due to its characteristic of minimal stent shortening. Endoscopic stent removal is sometimes recommended for recurrent biliary obstruction (RBO). However, there are no previous reports of endoscopic removal of laser-cut CSEMS. The current study presents data from 6 patients who were placed a laser-cut CSEMS for unresectable distal malignant biliary strictures, and later endoscopic stent removal was attempted for RBO at the present institute. The duration of stent placement, the procedural success rate, the procedural duration, and accidental complications were evaluated. The mean duration of stent placement was 156±37.9 days (range, 117-205). The procedural success rate was 100%. The mean procedural duration was 11.8±7.5 min (range, 5-24). No complications were reported. Laser-cut CSEMS were safely removed from all patients. The present case report is the first to demonstrate that Endoscopic stent removal of laser-cut CSEMS was safely performed.
Abdel Razek, Ahmed Abdel Khalek; Nada, Nadia
2018-05-01
The prognostic parameters of head and neck squamous cell carcinoma (HNSCC) include the pathological degree of tumor differentiation, clinical staging, and presence of metastatic cervical lymph nodes. To correlate tumor blood flow (TBF) acquired from arterial spin labeling (ASL) perfusion-weighted MR imaging with pathological degree of tumor differentiation, clinical stage, and nodal metastasis of HNSCC. Retrospective analysis of 43 patients (31 male, 12 female with a mean age of 65 years) with HNSCC that underwent ASL of head and neck and TBF of HNSCC was calculated. Tumor staging and metastatic lymph nodes were determined. The stages of HNSCC were stage 1 (n = 7), stage II (n = 12), stage III (n = 11) and stage IV (n = 13). Metastatic cervical lymph nodes were seen in 24 patients. The degree of tumor differentiation was determined through pathological examination. The mean TBF of poorly and undifferentiated HNSCC (157.4 ± 6.7 mL/100 g/min) was significantly different (P = 0.001) than that of well-to-moderately differentiated (142.5 ± 5.7 mL/100 g/min) HNSCC. The cut-off TBF used to differentiate well-moderately differentiated from poorly and undifferentiated HNSCC was 152 mL/100 g/min with an area under the curve of 0.658 and accuracy of 88.4%. The mean TBF of stages I, II (146.10 ± 9.1 mL/100 g/min) was significantly different (P = 0.014) than that of stages III, IV (153.33 ± 9.3 mL/100 g/min) HNSCC. The cut-off TBF used to differentiate stages I, II from stages III and IV was 148 mL/100 g/min with an area under the curve of 0.701 and accuracy of 69.8%. The TBF was higher in patients with metastatic cervical lymph nodes. The cut-off TBF suspect metastatic node was 147 mL/100 g/min with an area under the curve of 0.671 and accuracy of 67.4%. TBF is a non-invasive imaging parameter that well correlated with pathological degree of tumor differentiation, clinical stage of tumor and nodal metastasis of HNSCC.
2011-01-01
Background There is a need for valid population level measures of physical activity in young children. The aim of this paper is to report the development, and the reliability and validity, of the Preschool-age Children's Physical Activity Questionnaire (Pre-PAQ) which was designed to measure activity of preschool-age children in the home environment in population studies. Methods Pre-PAQ was completed by 103 families, and validated against accelerometry for 67 children (mean age 3.8 years, SD 0.74; males 53%). Pre-PAQ categorizes activity into five progressive levels (stationary no movement, stationary with limb or trunk movement, slow, medium, or fast-paced activity). Pre-PAQ Levels 1-2 (stationary activities) were combined for analyses. Accelerometer data were categorized for stationary, sedentary (SED), non-sedentary (non-SED), light (LPA), moderate (MPA) and vigorous (VPA) physical activity using manufacturer's advice (stationary) or the cut-points described by Sirard et al and Reilly et al. Bland-Altman methods were used to assess agreement between the questionnaire and the accelerometer measures for corresponding activity levels. Reliability of the Pre-PAQ over one week was determined using intraclass correlations (ICC) or kappa (κ) values and percentage of agreement of responses between the two questionnaire administrations. Results Pre-PAQ had good agreement with LPA (mean difference 1.9 mins.day-1) and VPA (mean difference -4.8 mins.day-1), was adequate for stationary activity (mean difference 7.6 mins.day-1) and poor for sedentary activity, whether defined using the cut-points of Sirard et al (mean difference -235.4 mins.day-1) or Reilly et al (mean difference -208.6 mins.day-1) cut-points. Mean difference between the measures for total activity (i.e. Reilly's non-sedentary or Sirard's LMVPA) was 20.9 mins.day-1 and 45.2 mins.day-1. The limits of agreement were wide for all categories. The reliability of Pre-PAQ question responses ranged from 0.31-1.00 (ICC (2, 1)) for continuous measures and 0.60-0.97 (κ) for categorical measures. Conclusions Pre-PAQ has acceptable validity and reliability and appears promising as a population measure of activity behavior but it requires further testing on a more broadly representative population to affirm this. Pre-PAQ fills an important niche for researchers to measure activity in preschool-age children and concurrently to measure parental, family and neighborhood factors that influence these behaviors. PMID:21813025
Dwyer, Genevieve M; Hardy, Louise L; Peat, Jennifer K; Baur, Louise A
2011-08-04
There is a need for valid population level measures of physical activity in young children. The aim of this paper is to report the development, and the reliability and validity, of the Preschool-age Children's Physical Activity Questionnaire (Pre-PAQ) which was designed to measure activity of preschool-age children in the home environment in population studies. Pre-PAQ was completed by 103 families, and validated against accelerometry for 67 children (mean age 3.8 years, SD 0.74; males 53%). Pre-PAQ categorizes activity into five progressive levels (stationary no movement, stationary with limb or trunk movement, slow, medium, or fast-paced activity). Pre-PAQ Levels 1-2 (stationary activities) were combined for analyses. Accelerometer data were categorized for stationary, sedentary (SED), non-sedentary (non-SED), light (LPA), moderate (MPA) and vigorous (VPA) physical activity using manufacturer's advice (stationary) or the cut-points described by Sirard et al and Reilly et al. Bland-Altman methods were used to assess agreement between the questionnaire and the accelerometer measures for corresponding activity levels. Reliability of the Pre-PAQ over one week was determined using intraclass correlations (ICC) or kappa (κ) values and percentage of agreement of responses between the two questionnaire administrations. Pre-PAQ had good agreement with LPA (mean difference 1.9 mins.day⁻¹) and VPA (mean difference -4.8 mins.day⁻¹), was adequate for stationary activity (mean difference 7.6 mins.day⁻¹) and poor for sedentary activity, whether defined using the cut-points of Sirard et al (mean difference -235.4 mins.day⁻¹) or Reilly et al (mean difference -208.6 mins.day⁻¹) cut-points. Mean difference between the measures for total activity (i.e. Reilly's non-sedentary or Sirard's LMVPA) was 20.9 mins.day⁻¹ and 45.2 mins.day⁻¹. The limits of agreement were wide for all categories. The reliability of Pre-PAQ question responses ranged from 0.31-1.00 (ICC (2, 1)) for continuous measures and 0.60-0.97 (κ) for categorical measures. Pre-PAQ has acceptable validity and reliability and appears promising as a population measure of activity behavior but it requires further testing on a more broadly representative population to affirm this. Pre-PAQ fills an important niche for researchers to measure activity in preschool-age children and concurrently to measure parental, family and neighborhood factors that influence these behaviors.
Liu, Hui; Zhao, Li-Xia; Xu, Guang; Yao, Ming-Hua; Zhang, Ai-Hong; Xu, Hui-Xiong; Wu, Rong
2015-01-01
The study was to explore diagnostic value of the virtual touch tissue imaging quantification (VTIQ) in distinguishing benign and malignant breast lesions of variable sizes. We performed conventional ultrasound and VTIQ in 139 breast lesions. The lesions were categorized into three groups according to size (group 1, ≤ 10 mm; group 2, 10-20 mm; and group 3, > 20 mm), and their mean, min, and max shear wave velocities (SWVs) were measured. Diagnoses were confirmed by pathological examination after surgery or needle biopsy. Receiver-operating characteristic curves (ROC) were constructed to determine the optimum cut-off values, calculate the area under curve (AUC), the sensitivity, specificity and accuracy for each velocity. For all groups, the mean, min, and max SWVs of malignant lesions were significantly higher than those of benign lesions (P < 0.05). The cut-off values of mean, min, and max SWVs were not significantly different among the three groups. In addition, the diagnostic performance of mean, min, and max SWV values is analogous, regardless of lesion size. In conclusion, VTIQ is a strong complement to conventional ultrasound, which is a promising method in the differential diagnosis of the breast lesions with different sizes. Further studies validate our results as well as reduce the number of unnecessary biopsies, regardless of size is warranted. PMID:26550234
Tibana, Ramires A; Nascimento, Dahan da C; de Sousa, Nuno M F; de Almeida, Jeeser A; Moraes, Milton R; Durigan, João Luiz Quagliotti; Collier, Scott R; Prestes, Jonato
2015-11-01
The aim of the present study was to compare the response of systolic blood pressure (SBP), mean blood pressure (MBP) and diastolic blood pressure (DBP) following combined training with 1 set or with 3 sets of resistance exercise (RE). Sixteen women with metabolic syndrome (MetS) were randomly assigned to perform two combined exercise protocols and a control session (CON): 1-set, 30 min of aerobic exercise (AE) at 65-70% of reserve heart rate and 1 set of 8-12 repetitions at 80% of 10-RM in six resistance exercises; 3-sets, same protocol but with 3 sets; and CON, 30 min of seated rest. The SBP, MBP and DBP were measured before and every 15 min during 90 min following the experimental sessions. The SBP displayed a decrease (P ≤ 0.05) during the 90 min following the RE session with 1-set and 3-set, while MBP was decreased (P ≤ 0.05) up to 75 min after 1-set and up to 30 min after the 3-set exercise session compared with pre-intervention values. There was a decrease in DBP only for the greatest individual decrease following 1-set (-6.1 mmHg) and 3-set (-4.9 mmHg) combined exercise sessions, without differences between them. The rate-pressure product and heart rate remained significantly higher (P ≤ 0.05) 75 min and 90 min after the combined exercise session with 1- and 3-sets compared with the CON, respectively. In conclusion, a low-volume RE combined with AE resulted in similar decrease of SBP when compared with RE with 3-sets in women with MetS, which could be beneficial in situations of limited time. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Venkatesan, K
2017-07-01
Inconel 718, a high-temperature alloy, is a promising material for high-performance aerospace gas turbine engines components. However, the machining of the alloy is difficult owing to immense shear strength, rapid work hardening rate during turning, and less thermal conductivity. Hence, like ceramics and composites, the machining of this alloy is considered as difficult-to-turn materials. Laser assisted turning method has become a promising solution in recent years to lessen cutting stress when materials that are considered difficult-to-turn, such as Inconel 718 is employed. This study investigated the influence of input variables of laser assisted machining on the machinability aspect of the Inconel 718. The comparison of machining characteristics has been carried out to analyze the process benefits with the variation of laser machining variables. The laser assisted machining variables are cutting speeds of 60-150 m/min, feed rates of 0.05-0.125 mm/rev with a laser power between 1200 W and 1300 W. The various output characteristics such as force, roughness, tool life and geometrical characteristic of chip are investigated and compared with conventional machining without application of laser power. From experimental results, at a laser power of 1200 W, laser assisted turning outperforms conventional machining by 2.10 times lessening in cutting force, 46% reduction in surface roughness as well as 66% improvement in tool life when compared that of conventional machining. Compared to conventional machining, with the application of laser, the cutting speed of carbide tool has increased to a cutting condition of 150 m/min, 0.125 mm/rev. Microstructural analysis shows that no damage of the subsurface of the workpiece.
NASA Astrophysics Data System (ADS)
Schrock, David James
The objective of this work is to identify some of the tool wear mechanisms at the material level for the machining of titanium and to provide some understanding of these mechanisms for use in physics based tool wear models. Turning experiments were conducted at cutting speeds of 61m/min, 91m/min, and 122m/min on Ti-6Al-4V, an alloy of titanium, using two different grades of tungsten carbide cutting inserts and one grade of polycrystalline diamond inserts. Three-dimensional wear data and two-dimensional wear profiles of the rake face were generated using Confocal Laser Scanning Microscopy to quantify the tool wear mechanisms. Additionally, the microstructure of the deformed work material (chip) and un-deformed parent material (work piece) were studied using Orientation Imaging Microscopy (OIM). Observations from tool wear studies on the PCD inserts revealed the presence of two fundamentally different wear mechanisms operating at the different cutting speeds. Microstructural analyses of the chip and the work material showed phase dependent tool wear mechanisms for machining titanium. There is a high likelihood of phase change occurring in the work material during machining, with a transformation from the alpha phase to the beta phase. The observed dramatic increase in wear is attributed to a combination of increased diffusivity in the beta phase of the titanium alloy in conjunction with a higher degree of recrystallization of the prior beta phase upon cooling. Results of other observations such as the influence of carbide grain size on tool wear are also discussed.
Development of AISI 316L stainless steel coronary stent
NASA Astrophysics Data System (ADS)
García-López, Erika; Siller, Héctor R.; Rodríguez, Ciro A.
2018-02-01
Coronary stents are manufactured through a sequence of processes and each step demands the process control to assure surface quality. This study is focused on the influence of laser cutting parameters and electropolishing on average surface roughness and back wall dross percentage for fiber laser cutting of AISI 316L coronary struts. A preliminary test and a design of experiments (DOE) were implemented to determine the limiting cutting conditions and the effect of these parameters on quality indicators. Preliminary results identify four cutting zones from a non-cut zone to a burned zone, in a frequency range between 1000 and 1500 Hz and a peak power between 160 to 180 W for clean cuts. From the DOE results, several interactions between factors were observed; however, a laser frequency of 1000 to 1500 Hz and a cutting speed of 250 mm/min minimize the backwall dross percentage and the surface roughness to values less than 2% and 0.9 μm, respectively. After the laser conditions selection, coronary stents were manufactured and electropolished to reduce the surface roughness on the strut edge. Electropolishing results indicate a surface roughness reduction from 0.9 μm to 0.3 μm after 300 s of electropolishing time.
HEUS, Ronald; DENHARTOG, Emiel A.
2017-01-01
To determine safe working conditions in emergency situations at petro-chemical plants in the Netherlands a study was performed on three protective clothing combinations (operator’s, firefighter’s and aluminized). The clothing was evaluated at four different heat radiation levels (3.0, 4.6, 6.3 and 10.0 k∙W∙m−2) in standing and walking posture with a thermal manikin RadMan™. Time till pain threshold (43°C) is set as a cut-off criterion for regular activities. Operator’s clothing did not fulfil requirements to serve as protective clothing for necessary activities at heat radiation levels above 1.5 k∙W∙m−2 as was stated earlier by Den Hartog and Heus1). With firefighter’s clothing it was possible to work almost three min up to 4.6 k∙W∙m−2. At higher heat radiation levels firefighter’s clothing gave insufficient protection and aluminized clothing should be used. Maximum working times in aluminized clothing at 6.3 k∙W∙m−2 was about five min. At levels of 10.0 k∙W∙m−2 (emergency conditions) emergency responders should move immediately to lower heat radiation levels. PMID:28978903
Gender Difference of Gastric Emptying in Healthy Volunteers and Patients with Functional Dyspepsia.
Mori, Hideki; Suzuki, Hidekazu; Matsuzaki, Juntaro; Taniguchi, Kanami; Shimizu, Toshiyuki; Yamane, Tsuyoshi; Masaoka, Tatsuhiro; Kanai, Takanori
2017-01-01
Delayed gastric emptying is one of the reasons why functional dyspepsia (FD) occurs. The 13C-acetate breath test is widely used to evaluate gastric emptying. Nevertheless, the standard value of 13C-acetate breath test has not taken into account the gender difference of gastric emptying among healthy individuals. The main aim of this study was to readjust the standard value of 13C-acetate breath test in the light of gender differences. In addition, we clarified the prevalence and clinical characteristics of delayed gastric emptying in patients with FD using the modified standard values of 13C-acetate breath test. Fifty-two healthy individuals and 126 patients with patients with FD were enrolled. Gastric emptying was evaluated by the 13C-acetate breath test. The cut-off points of Tmax for the diagnosis of delayed gastric emptying were determined on the basis of results from healthy individuals making a distinction of genders. Gastroesophageal reflux symptoms, dyspeptic symptoms, scores of anxiety and depression, age, body mass index (BMI), smoking and alcohol consumption were compared between the delayed gastric emptying group and the non-delayed gastric emptying group. Since gastric emptying was delayed in healthy women compared with that in healthy men (Tmax, 53.6 ± 19.3 vs. 42.7 ± 16.9 min, p = 0.04), we set the cut-off points of Tmax at 60 min in men and at 75 min in women. In patients with FD, the prevalence of delayed gastric emptying was not different between men and women with the modified standard values of 13C-acetate breath test. (31.0 vs. 27.4%, p = 0.68). BMI was lower in the delayed gastric emptying group than in the non-delayed group among the male patients. Reflux symptoms were more severe in delayed gastric emptying group than in the non-delayed group among the female patients. The standard values of 13C-acetate breath test should be modified bearing the gender difference in mind. It provides us more appropriate information to understand the mechanisms of FD. © 2016 S. Karger AG, Basel.
Kim, Yoon-Hee; Jeong, Seul-Gi; Back, Kyeong-Hwan; Park, Ki-Hwan; Chung, Myung-Sub; Kang, Dong-Hyun
2013-09-16
The effect of various conditions on inactivation of foodborne pathogens and quality of fresh-cut lettuce during ultraviolet (254 nm, UVC) radiation was investigated. Lettuce was inoculated with a cocktail of Escherichia coli O157:H7, Salmonella Typhimurium, and Listeria monocytogenes and treated at different temperatures (4 and 25 °C), distances between sample and lamp (10 and 50 cm), type of exposure (illuminated from one or two sides), UV intensities (1.36 to 6.80 mW/cm²), and exposure times (0.5 to 10 min), sequentially. UV treatment at 25 °C for 1 min achieved 1.45-, 1.35-, and 2.12-log reductions in surface-inoculated E. coli O157:H7, S. Typhimurium, and L. monocytogenes, respectively, whereas the reduction of these pathogens at 4 °C was 0.31, 0.57, and 1.16 log, respectively. UV radiation was most effective when distance from UV lamp to the sample was minimal (10 cm) and radiation area was maximal (two-sided exposure). All UV intensities significantly (P<0.05) reduced the three pathogens after 10 min exposure, but the effect of treatment was correlated with UV intensity and exposure time. Color values and texture parameters of lettuce subjected to UV treatment under the optimum conditions (25 °C, 10 cm between sample and lamp, two-sided exposure, 6.80 mW/cm²) were not significantly (P>0.05) different from those of nontreated samples up to 5 min exposure. However, these qualities significantly (P<0.05) changed at prolonged treatment time. These results suggest that UV radiation under optimized conditions could reduce foodborne pathogens without adversely affecting color quality properties of fresh-cut lettuce. © 2013 Elsevier B.V. All rights reserved.
Investigation of wear land and rate of locally made HSS cutting tool
NASA Astrophysics Data System (ADS)
Afolalu, S. A.; Abioye, A. A.; Dirisu, J. O.; Okokpujie, I. P.; Ajayi, O. O.; Adetunji, O. R.
2018-04-01
Production technology and machining are inseparable with cutting operation playing important roles. Investigation of wear land and rate of cutting tool developed locally (C=0.56%) with an HSS cutting tool (C=0.65%) as a control was carried out. Wear rate test was carried out using Rotopol -V and Impact tester. The samples (12) of locally made cutting tools and one (1) sample of a control HSS cutting tool were weighed to get the initial weight and grit was fixed at a point for the sample to revolve at a specific time of 10 mins interval. Approach of macro transfer particles that involved mechanism of abrasion and adhesion which was termed as mechanical wear to handle abrasion adhesion processes was used in developing equation for growth wear at flank. It was observed from the wear test that best minimum wear rate of 1.09 × 10-8 and 2.053 × 10-8 for the tools developed and control were measured. MATLAB was used to simulate the wear land and rate under different conditions. Validated results of both the experimental and modeling showed that cutting speed has effect on wear rate while cutting time has predicted measure on wear land. Both experimental and modeling result showed best performances of tools developed over the control.
Efficient Interconnection Schemes for VLSI and Parallel Computation
1989-08-01
Definition: Let R be a routing network. A set S of wires in R is a (directed) cut if it partitions the network into two sets of processors A and B ...such that every path from a processor in A to a processor in B contains a wire in S. The capacity cap(S) is the number of wires in the cut. For a set of...messages M, define the load load(M, S) of M on a cut S to be the number of messages in M from a processor in A to a processor in B . The load factor
Hyperspectral Image Classification With Markov Random Fields and a Convolutional Neural Network
NASA Astrophysics Data System (ADS)
Cao, Xiangyong; Zhou, Feng; Xu, Lin; Meng, Deyu; Xu, Zongben; Paisley, John
2018-05-01
This paper presents a new supervised classification algorithm for remotely sensed hyperspectral image (HSI) which integrates spectral and spatial information in a unified Bayesian framework. First, we formulate the HSI classification problem from a Bayesian perspective. Then, we adopt a convolutional neural network (CNN) to learn the posterior class distributions using a patch-wise training strategy to better use the spatial information. Next, spatial information is further considered by placing a spatial smoothness prior on the labels. Finally, we iteratively update the CNN parameters using stochastic gradient decent (SGD) and update the class labels of all pixel vectors using an alpha-expansion min-cut-based algorithm. Compared with other state-of-the-art methods, the proposed classification method achieves better performance on one synthetic dataset and two benchmark HSI datasets in a number of experimental settings.
Todd Rogers, W; Docherty, David; Petersen, Stewart
2014-01-01
The bookmark method for setting cut-scores was used to re-set the cut-score for the Canadian Forces Firefighter Physical Fitness Maintenance Evaluation (FF PFME). The time required to complete 10 tasks that together simulate a first-response firefighting emergency was accepted as a measure of work capacity. A panel of 25 Canadian Forces firefighter supervisors set cut-scores in three rounds. Each round involved independent evaluation of nine video work samples, where the times systematically increased from 400 seconds to 560 seconds. Results for Round 1 were discussed before moving to Round 2 and results for Round 2 were discussed before moving to Round 3. Accounting for the variability among panel members at the end of Round 3, a cut-score of 481 seconds (mean Round 3 plus 2 SEM) was recommended. Firefighters who complete the FF PFME in 481 seconds or less have the physical capacity to complete first-response firefighting work.
Automatic Optical Crack Tracking for Double Cantilever Beam Specimens
2015-01-01
Developments Corp., Brookeville, OH, USA) are stacked in a [90/0]8 layup sequence. An Ethylene tetrafluoroethylene ( ETFE ) film (25μm thick) is placed...DCB samples are cut using a diamond-blade wet saw from the 4-mm-thick panel to approximately 25 mm wide and 150 mm long (60 mm ETFE , 90 mm neat...to the interior ETFE film termination interface is approximately 47 mm. Crosshead speed is (+) 5 mm/min during loading and (−) 25 mm/min for
George, Rubin; Menon, Vidya P; Edathadathil, Fabia; Balachandran, Sabarish; Moni, Merlin; Sathyapalan, Dipu; Prasanna, Preetha; S, Gokuldas; Paul, Jerry; K K, Chandrababu; Kumar, Lakshmi; Pillai, Ashok
2018-05-01
Asymptomatic myocardial injury following noncardiac surgery (MINS) is an independent predictor of 30-day mortality and may go unrecognized based on standard diagnostic definition for myocardial infarction (MI). Given lack of published research on MINS in India, our study aims to determine incidence of MINS in patients undergoing noncardiac surgery at our tertiary care hospital, and evaluate the clinical characteristics including 30-day outcome.The prospective observational study included patients >65 years or >45 years with either hypertension (HTN), diabetes mellitus (DM), coronary artery disease (CAD), cerebrovascular accident (CVA), or peripheral arterial disease undergoing noncardiac surgery. MINS was peak troponin level of ≥0.03 ng/dL at 12-hour or 24-hour postoperative. All patients were followed for 30 days postoperatively. Predictors of MINS and mortality were analyzed using multivariate logistic regression. Patients categorized based on peak troponin cut-off values determined by receiver operating characteristic curve were analyzed by Kaplan-Meir test to compare the survival of patients between the groups.Among 1075 patients screened during 34-month period, the incidence of MINS was 17.5% (188/1075). Patients with DM, CAD, or who underwent peripheral nerve block anaesthesia were 1.5 (P < .01), 2 (P < .001), and 12 (P < .001) times, respectively, more likely to develop MINS than others. Patients with heart rates ≥96 bpm before induction of anesthesia were significantly associated with MINS (P = .005) and mortality (P = .02). The 30-day mortality in MINS cohort was 11.7% (22/188, 95% CI 7.5%-17.2%) vs 2.5% (23/887, 95% CI 1.7%-3.9%) in patients without MINS (P < .001). ECG changes (P = .002), peak troponin values >1 ng/mL (P = .01) were significantly associated with mortality. A peak troponin cut-off of >0.152 ng/mL predicted mortality among MINS patients at 72% sensitivity and 58% specificity. Lack of antithrombotic therapy following MINS was independent predictor of mortality (P < .001), with decreased mortality in patients who took post-op ASA (Aspirin) or Clopidogrel. Mortality among MINS patients with post-op ASA intake is 6.7% vs 12.1% among MINS patients without post-op ASA intake. Mortality among MINS patients with post-op Clopidogrel intake is 10.5% vs 11.8% among MINS patients without post-op Clopidogrel intake.A higher (17.5%, 95% CI 15-19%) incidence of MINS was observed in our patient cohort with significant association with 30-day mortality. Serial postoperative monitoring of troponin following noncardiac surgery as standard of care, would identify "at risk" patients translating to improved outcomes.
Predicted yields from selected cutting prescriptions in northern Minnesota.
Pamela J. Jakes; W. Brad Smith
1980-01-01
Includes predicted yields based on two sets of cutting prescriptions in northern Minnesota. Indicates that given a specific set of assumptions, average annual growing-stock removals for the decade 1977-1986 would be from 69% to 124% higher than 1976 growing-stock removals.
Electrical contact tool set station
Byers, M.E.
1988-02-22
An apparatus is provided for the precise setting to zero of electrically conductive cutting tools used in the machining of work pieces. An electrically conductive cylindrical pin, tapered at one end to a small flat, rests in a vee-shaped channel in a base so that its longitudinal axis is parallel to the longitudinal axis of the machine's spindle. Electronic apparatus is connected between the cylindrical pin and the electrically conductive cutting tool to produce a detectable signal when contact between tool and pin is made. The axes of the machine are set to zero by contact between the cutting tool and the sides, end or top of the cylindrical pin. Upon contact, an electrical circuit is completed, and the detectable signal is produced. The tool can then be set to zero for that axis. Should the tool contact the cylindrical pin with too much force, the cylindrical pin would be harmlessly dislodged from the vee-shaped channel, preventing damage either to the cutting tool or the cylindrical pin. 5 figs.
A fast bottom-up algorithm for computing the cut sets of noncoherent fault trees
DOE Office of Scientific and Technical Information (OSTI.GOV)
Corynen, G.C.
1987-11-01
An efficient procedure for finding the cut sets of large fault trees has been developed. Designed to address coherent or noncoherent systems, dependent events, shared or common-cause events, the method - called SHORTCUT - is based on a fast algorithm for transforming a noncoherent tree into a quasi-coherent tree (COHERE), and on a new algorithm for reducing cut sets (SUBSET). To assure sufficient clarity and precision, the procedure is discussed in the language of simple sets, which is also developed in this report. Although the new method has not yet been fully implemented on the computer, we report theoretical worst-casemore » estimates of its computational complexity. 12 refs., 10 figs.« less
Taxing sugar-sweetened beverages: a survey of knowledge, attitudes and behaviours
Rivard, Cheryl; Smith, Danielle; McCann, Susan E; Hyland, Andrew
2016-01-01
Objective To assess current beverage consumption patterns and anticipated reaction to an added 20% tax on these products. Design A random-digit dialled telephone interview lasting 20min was administered to assess demographics, beverage consumption behaviours and intentions regarding consumption of sugar-sweetened beverages in the event of an additional tax on these beverages. Setting Respondents were recruited throughout the USA. Subjects The study included 592 adults. Results Sixty-nine per cent of respondents reported consuming at least one prepackaged sugar-sweetened beverage in the past week; those who consumed sugar-sweetened beverages averaged seven pre-packaged beverages per week. Ninety-one per cent knew that frequent consumption of soft drinks increases risk of obesity. Thirty-six per cent supported a tax on sugar-sweetened beverages with greatest support among those aged 18–24 years, those with BMI<30kg/m2 and those with higher levels of education (P<0.05). Over one-third of respondents said that they would cut back on their sweetened beverage consumption in the event of an added 20% tax on these beverages. Conclusions Our findings suggest that an added tax on these beverages could influence some to cut down on their consumption, reducing their risk of obesity and related illnesses. PMID:22269063
Parametric effects of turning Ti-6Al-4V alloys with aluminum oxide nanolubricants with SDBS
NASA Astrophysics Data System (ADS)
Ali, M. A. M.; Azmi, A. I.; Khalil, A. N. M.
2017-09-01
Applications of nanolubricants have been claimed to improve machinability of aerospace metals due to reduction of friction as a results of the rolling action of billions of nanoparticles at the tool-chip interface. In addition, the need to pursue for an eco-friendly machining has pushed researchers toward implementing alternative lubrication methods through minimal quantity lubrication (MQL). However, the gap in the current literature regarding the performance of nanolubricants via MQL has restricted the widespread use of this lubricant and technique in industries. The present work aims to understand the parametric effects of nanoparticles concentration, cutting speed, feed rate and nozzle angle during machining of titanium alloy, Ti-6AL-4V. Multiple performance of machinability outputs such as surface roughness, tool wear and power consumption were simultaneously determined via Taguchi orthogonal array and grey relational analyses. Prior to machining tests, the nanolubricants stabilities were investigated through the addition of surfactant; sodium dodecyl benzene sulfonate (SDBS). The results clearly indicated that inclusion of SDBS surfactant managed to reduce agglomeration in the base lubricant. Meanwhile, grey relational analyses revealed that the combination of 0.6 % nanoparticles concentration, cutting speed of 85 m/min, feed rate of 0.1 mm/rev and nozzle angle of 60o as desired setting for all the three machining outputs.
Abreu, Celina Wanderley; Santosb, Jarbas F; Passos, Sheila Pestana; Michida, Silvia Masae; Takahashi, Fernando Eidi; Bottino, Marco Antonio
2011-06-01
This study evaluated the effect of cutting initiation location and cutting speed on the bond strength between resin cement and feldspathic ceramic. Thirty-six blocks (6.4 x 6.4 x 4.8 mm) of ceramic (Vita VM7) were produced. The ceramic surfaces were etched with 10% hydrofluoric acid gel for 60 s and then silanized. Each ceramic block was placed in a silicon mold with the treated surface exposed. A resin cement (Variolink II) was injected into the mold over the treated surface and polymerized. The resin cement-ceramic blocks were divided into two groups according to experimental conditions: a) cutting initiation location - resin cement, ceramic and interface; and b) cutting speed - 10,000, 15,000, and 20,000 rpm. The specimens were sectioned to achieve non-trimmed bar specimens. The microtensile test was performed in a universal testing machine (1 mm/min). The failure modes were examined using an optical light microscope and SEM. Bond strength results were analyzed using one-way ANOVA and Tukey's test (α = 0.05). Significant influences of cutting speed and initiation location on bond strength (p < 0.05) were observed. The highest mean was achieved for specimens cut at 15,000 rpm at the interface (15.12 ± 5.36 MPa). The lowest means were obtained for specimens cut at the highest cutting speed in resin cement (8.50 ± 3.27 MPa), and cut at the lowest cutting speed in ceramic (8.60 ± 2.65 MPa). All groups showed mainly mixed failure (75% to 100%). The cutting speed and initiation location are important factors that should be considered during specimen preparation for microtensile bond strength testing, as both may influence the bond strength results.
Engineering the shape and structure of materials by fractal cut.
Cho, Yigil; Shin, Joong-Ho; Costa, Avelino; Kim, Tae Ann; Kunin, Valentin; Li, Ju; Lee, Su Yeon; Yang, Shu; Han, Heung Nam; Choi, In-Suk; Srolovitz, David J
2014-12-09
In this paper we discuss the transformation of a sheet of material into a wide range of desired shapes and patterns by introducing a set of simple cuts in a multilevel hierarchy with different motifs. Each choice of hierarchical cut motif and cut level allows the material to expand into a unique structure with a unique set of properties. We can reverse-engineer the desired expanded geometries to find the requisite cut pattern to produce it without changing the physical properties of the initial material. The concept was experimentally realized and applied to create an electrode that expands to >800% the original area with only very minor stretching of the underlying material. The generality of our approach greatly expands the design space for materials so that they can be tuned for diverse applications.
2013-01-01
Background To develop a side-view imaging technique for observing the dynamic behavior of posterior chamber structures (PCSs) in porcine eyes which mimics closed-eye cataract surgery in humans. Methods Enucleated porcine eyes were placed into liquid nitrogen for 5 seconds and immediately bisected at about a 45-degree angle to the equatorial plane. The anterior portion was attached firmly to a glass slide with superglue and sprinkled with wheat flour. Phacoemulsification and aspiration (PEA) was performed as in humans on 10 consecutive porcine eyes. The movements of the PCSs were monitored through the glass slide with a high-resolution video camera set below the cut surface of the eye. The intraocular pressure (IOP) was monitored during the surgery. The highest IOP, operation time, and volume of irrigation fluid of 10 whole eyes were compared to that obtained from the bisected eyes glued to a glass slide. In a second set of experiments, the strength of the seal between the bisected eye and the glass slide was tested in three sets of eyes: 1) frozen eye fixed with superglue with wheat flour for 3 min; 2) frozen eye fixed with superglue for 3 min; and 3) non-frozen eye fixed with superglue for 30 min. The highest IOP that led to a disruption of the seal was compared among the three groups. Results PEA was successfully performed on 9 of 10 (90%) eyes with the movements of the PCSs clearly observed. The average maximum intraocular pressure of the 9 bisected eyes was 55.8 ± 4.7 mmHg and that for the 10 unbisected eyes was 55.3 ± 5.0 mmHg (P = 0.650). The frozen eye fixed with superglue in combination with wheat flour (Group 1) had the strongest sealing strength with an average IOP at the breaking point of 117.3 ± 36.2 mmHg. Conclusions Our side-view imaging technique can be used to evaluate the changes of the PCSs during intraocular surgery and for surgical training of new residents. PMID:24053470
Supapvanich, S; Mitrsang, P; Srinorkham, P; Boonyaritthongchai, P; Wongs-Aree, C
2016-06-01
The effect of natural coating by using fresh Aloe vera (A. vera) gel alleviating browning of fresh-cut wax apple fruits cv. Taaptimjaan was investigated. The fresh-cut fruits were dipped in fresh A. vera gel at various concentrations of 0, 25, 75 or 100 % (v/v) for 2 min at 4 ± 1 °C for 6 days. Lightness (L*), whiteness index (WI), browning index (BI), total color difference (ΔE*), sensorial quality attributes, total phenolic (TP) content, antioxidant activity and polyphenol oxidase (PPO) and peroxidase (POD) activities were determined. During storage, L* and WI of the fresh-cut fruits surface decreased whilst their BI and ΔE* increased. A. vera coating maintained the L* and WI and delayed the increase in BI and ΔE*, especially at 75 % A. vera dip. The fresh-cut fruits dipped in 75 % A. vera had the lowest browning score, the highest acceptance score and delayed the increase in TP content and PPO activity. However POD activity was induced by A. vera coating. Antioxidant activity had no effect on browning incidence of the fresh-cut fruits. Consequently, A. vera gel coating could maintain quality and retarded browning of fresh-cut wax apple fruits during storage.
NASA Astrophysics Data System (ADS)
Yingfei, Ge; de Escalona, Patricia Muñoz; Galloway, Alexander
2017-01-01
The efficiency of a machining process can be measured by evaluating the quality of the machined surface and the tool wear rate. The research reported herein is mainly focused on the effect of cutting parameters and tool wear on the machined surface defects, surface roughness, deformation layer and residual stresses when dry milling Stellite 6, deposited by overlay on a carbon steel surface. The results showed that under the selected cutting conditions, abrasion, diffusion, peeling, chipping and breakage were the main tool wear mechanisms presented. Also the feed rate was the primary factor affecting the tool wear with an influence of 83%. With regard to the influence of cutting parameters on the surface roughness, the primary factors were feed rate and cutting speed with 57 and 38%, respectively. In addition, in general, as tool wear increased, the surface roughness increased and the deformation layer was found to be influenced more by the cutting parameters rather than the tool wear. Compressive residual stresses were observed in the un-machined surface, and when machining longer than 5 min, residual stress changed 100% from compression to tension. Finally, results showed that micro-crack initiation was the main mechanism for chip formation.
ERIC Educational Resources Information Center
Eckes, Thomas
2017-01-01
This paper presents an approach to standard setting that combines the prototype group method (PGM; Eckes, 2012) with a receiver operating characteristic (ROC) analysis. The combined PGM-ROC approach is applied to setting cut scores on a placement test of English as a foreign language (EFL). To implement the PGM, experts first named learners whom…
Rooting Cuttings of Cottonwood, WilIow, and Sycamore
Charles B. Briscoe
1963-01-01
Cuttings of cottonwood, willow, and sycamore were collectd monthly through the year and set in nursery beds. Every species yield an appreciable percentage of rooted cuttings every month. The best month was March; the worst month was June. Willow rooted more cuttings than cottonwood or sycamore, and those which rooted grew faster. Cottonwood grew faster than sycamore....
Cardiac tissue slices: preparation, handling, and successful optical mapping.
Wang, Ken; Lee, Peter; Mirams, Gary R; Sarathchandra, Padmini; Borg, Thomas K; Gavaghan, David J; Kohl, Peter; Bollensdorff, Christian
2015-05-01
Cardiac tissue slices are becoming increasingly popular as a model system for cardiac electrophysiology and pharmacology research and development. Here, we describe in detail the preparation, handling, and optical mapping of transmembrane potential and intracellular free calcium concentration transients (CaT) in ventricular tissue slices from guinea pigs and rabbits. Slices cut in the epicardium-tangential plane contained well-aligned in-slice myocardial cell strands ("fibers") in subepicardial and midmyocardial sections. Cut with a high-precision slow-advancing microtome at a thickness of 350 to 400 μm, tissue slices preserved essential action potential (AP) properties of the precutting Langendorff-perfused heart. We identified the need for a postcutting recovery period of 36 min (guinea pig) and 63 min (rabbit) to reach 97.5% of final steady-state values for AP duration (APD) (identified by exponential fitting). There was no significant difference between the postcutting recovery dynamics in slices obtained using 2,3-butanedione 2-monoxime or blebistatin as electromechanical uncouplers during the cutting process. A rapid increase in APD, seen after cutting, was caused by exposure to ice-cold solution during the slicing procedure, not by tissue injury, differences in uncouplers, or pH-buffers (bicarbonate; HEPES). To characterize intrinsic patterns of CaT, AP, and conduction, a combination of multipoint and field stimulation should be used to avoid misinterpretation based on source-sink effects. In summary, we describe in detail the preparation, mapping, and data analysis approaches for reproducible cardiac tissue slice-based investigations into AP and CaT dynamics. Copyright © 2015 the American Physiological Society.
Cardiac tissue slices: preparation, handling, and successful optical mapping
Wang, Ken; Lee, Peter; Mirams, Gary R.; Sarathchandra, Padmini; Borg, Thomas K.; Gavaghan, David J.; Kohl, Peter
2015-01-01
Cardiac tissue slices are becoming increasingly popular as a model system for cardiac electrophysiology and pharmacology research and development. Here, we describe in detail the preparation, handling, and optical mapping of transmembrane potential and intracellular free calcium concentration transients (CaT) in ventricular tissue slices from guinea pigs and rabbits. Slices cut in the epicardium-tangential plane contained well-aligned in-slice myocardial cell strands (“fibers”) in subepicardial and midmyocardial sections. Cut with a high-precision slow-advancing microtome at a thickness of 350 to 400 μm, tissue slices preserved essential action potential (AP) properties of the precutting Langendorff-perfused heart. We identified the need for a postcutting recovery period of 36 min (guinea pig) and 63 min (rabbit) to reach 97.5% of final steady-state values for AP duration (APD) (identified by exponential fitting). There was no significant difference between the postcutting recovery dynamics in slices obtained using 2,3-butanedione 2-monoxime or blebistatin as electromechanical uncouplers during the cutting process. A rapid increase in APD, seen after cutting, was caused by exposure to ice-cold solution during the slicing procedure, not by tissue injury, differences in uncouplers, or pH-buffers (bicarbonate; HEPES). To characterize intrinsic patterns of CaT, AP, and conduction, a combination of multipoint and field stimulation should be used to avoid misinterpretation based on source-sink effects. In summary, we describe in detail the preparation, mapping, and data analysis approaches for reproducible cardiac tissue slice-based investigations into AP and CaT dynamics. PMID:25595366
Sheng, Ning; Zheng, Hao; Xiao, Yao; Wang, Zhe; Li, Menglin; Zhang, Jinlan
2017-09-29
Chemical profile for Chinese medicine formulas composed of several herbs is always a challenge due to a big array of small molecules with high chemical diversity so much as isomers. The present paper develops a feasible strategy to characterize and identify complex chemical constituents of a four-herb traditional Chinese medicine formula, Denzhan Shenmai (DZSM) by integrating comprehensive two-dimensional liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (LC×LC-qTOF-MS) with multiple heart-cutting two-dimensional liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (MHC-qTOF-MS). DZSM was separated by C8×C18 HPLC column system for comprehensive two-dimensional liquid chromatography system and 283 compounds most of which belonged to phenolic acid, flavonoid, saponin and lignan families were characterized and identified within 75min. Some isomers and compounds at low level were analyzed on C8×Chiral HPLC column system for multiple heart-cutting two-dimensional liquid chromatography system with 1D and 2D optimized gradient elution program. These 1D cutting fractions were successively separated on 2D chiral chromatographic column under extended the 2D gradient elution time from 30s to 5.0min. 12 pairs of isomer compounds were separated with good resolution. The combination of LC×LC and MHC system provides a powerful technique for global chemical profiling of DZSM and provided feasible strategy for other complex systems. Copyright © 2017 Elsevier B.V. All rights reserved.
Predicting successful supraclavicular brachial plexus block using pulse oximeter perfusion index.
Abdelnasser, A; Abdelhamid, B; Elsonbaty, A; Hasanin, A; Rady, A
2017-08-01
Supraclavicular nerve block is a popular approach for anaesthesia for upper limb surgeries. Conventional methods for evaluation of block success are time consuming and need patient cooperation. The aim of this study was to evaluate whether the perfusion index (PI) can be used to predict and provide a cut-off value for ultrasound-guided supraclavicular nerve block success. The study included 77 patients undergoing elective orthopaedic procedures under ultrasound-guided supraclavicular nerve block. After local anaesthetic injection, sensory block success was assessed every 3 min by pinprick, and motor block success was assessed every 5 min by the ability to flex the elbow and the hand against resistance. The PI was recorded at baseline and at 10, 20, and 30 min after anaesthetic injection in both blocked and non-blocked limbs. The PI ratio was calculated as the PI after 10 min divided by the PI at the baseline. Receiver operating characteristic curves were constructed for the accuracy of the PI in detection of block success. The PI was higher in the blocked limb at all time points, and this was paralleled by a higher PI ratio compared with the unblocked limb. Both the PI and the PI ratio at 10 min after injection showed a sensitivity and specificity of 100% for block success at cut-off values of 3.3 and 1.4, respectively. The PI is a useful tool for evaluation of successful supraclavicular nerve block. A PI ratio of > 1.4 is a good predictor for block success. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Setting Meaningful Criterion-Reference Cut Scores as an Effective Professional Development
ERIC Educational Resources Information Center
Munyofu, Paul
2010-01-01
The state of Pennsylvania, like many organizations interested in performance improvement, routinely engages in professional development activities. Educators in this hands-on activity engaged in setting meaningful criterion-referenced cut scores for career and technical education assessments using two methods. The main purposes of this study were…
Nicholson, Timothy M.; Kahler, Bill
2017-01-01
This study explored an alternative approach using rheology to assess setting time. The following cements were tested: ProRoot® MTA (Dentsply, Tulsa, OK, USA), Biodentine® (Septodont, Saint Maur des Fosses, France), Fuji VII®, FujiVII® EP, and Fuji IX® (from GC Corporation, Tokyo, Japan), RealSeal SE™ Sealer (SybronEndo, Amersfoort, The Netherlands), AH 26® and AH Plus (both from Dentsply DeTrey, Konstanz, Germany). Freshly mixed cements were placed into a strain-controlled rheometer (1 rad·s−1 with an applied strain of 0.01%). From measurements of elastic modulus over time, the time taken to reach 90% of the plateau elastic modulus (designated as the setting time) was determined for each cement. In increasing order, the setting times were as follows: Fuji VII EP 3.3 min, Fuji VII 3.6 min, Fuji IX 3.7 min, ProRoot MTA 5.1 min, Biodentine 15.9 min, RealSeal 22.2 min, AH Plus 5933 min, and AH 26 5067 min. However, ProRoot MTA did not yield reliable results. The time to reach the 90% plateau elastic modulus correlates well with the setting time of glass ionomer cements and Biodentine. Using this approach gives much longer setting times for endodontic sealers than previously recognized. PMID:29261125
Madentzidou, Eleftheria; Gerasopoulos, Dimitrios; Siomos, Anastasios; Bloukas, Ioannis
2012-12-01
Fresh cut leek was mixed with salt for 0.5 (IM) and 5 (LM) min or remained untreated (control) and stored alone or mixed with minced meat and seasonings, cased and stored at 15 °C for 7 days. The fresh cut leek and sausage metabolics and sausage microbiological and physicochemical traits were measured during storage. Sausages with LM leek had significantly higher counts of lactic acid bacteria, faster rates of pH drop and dehydration and increased red color compared with the other treatments. Sausage to fresh cut leek peaks of CO₂ or C₂H₄ production was 5 or 2 fold higher in LM than the other treatments indicating that the sausage flora was the source of both. The use of salt-stressed fresh cut leek before manufacture of sausages enhances microbial activity as well as its stability and shortens the necessary storage time needed for the development of the quality characteristics of Greek traditional sausages. Copyright © 2012 Elsevier Ltd. All rights reserved.
Nowacka, Malgorzata; Fijalkowska, Aleksandra; Wiktor, Artur; Dadan, Magdalena; Tylewicz, Urszula; Dalla Rosa, Marco; Witrowa-Rajchert, Dorota
2018-02-01
The aim of the study was to investigate the effect of ultrasound treatment in two osmotic solutions, carried out at different time, on some physical properties, antioxidant activity and cell survival of cranberries. Ultrasound treatment was conducted at 21kHz for 30 and 60min in liquid medium: 61.5% sucrose solution and 30% sucrose solution with 0.1% steviol glycosides addition. Some samples before the ultrasound treatment were subjected to cutting or blanching. The results showed that dry matter content and concentration of the dissolved substances increased during ultrasound treatment in osmotic solution, however higher value was observed for treatment in 61.5% sucrose solution and for longer time. Water activity and volume of cranberries did not change after the ultrasonic treatment. Combined treatment led to colour and antioxidant activity alterations as well. A cell viability of whole and cut samples decreased after 60min of osmotic treatment and completely lost in the blanched samples. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Singh, Nepal; Singh, Rakesh K.; Bhunia, Arun K.; Stroshine, Richard L.; Simon, James E.
2001-03-01
There have been numerous studies on effectiveness of different sanitizers for microbial inactivation. However, results obtained from different studies indicate that microorganism cannot be easily removed from fresh cut vegetables because of puncture and cut surfaces with varying surface topographies. In this study, three step disinfection approach was evaluated for inactivation of E. coli O157:H7 on shredded lettuce leaves. Sequential application of thyme oil, ozonated water, and aqueous chlorine dioxide was evaluated in which thyme oil was applied first followed by ozonated water and aqueous chlorine dioxide. Shredded lettuce leaves inoculated with cocktail culture of E. coli O157:H7 (C7927, EDL 933 and 204 P), were washed with ozonated water (15 mg/l for 10min), aqueous chlorine dioxide (10 mg/l,for 10min) and thyme oil suspension (0.1%, v/v for 5min). Washing of lettuce leaves with ozonated water, chlorine dioxide and thyme oil suspension resulted in 0.44, 1.20, and 1.46 log reduction (log10 cfu/g), respectively. However, the sequential treatment achieved approximately 3.13 log reductions (log10 cfu/g). These results demonstrate the efficacy of sequential treatments in decontaminating shredded lettuce leaves containing E. coli O157:H7.
Shulruf, Boaz; Turner, Rolf; Poole, Phillippa; Wilkinson, Tim
2013-05-01
The decision to pass or fail a medical student is a 'high stakes' one. The aim of this study is to introduce and demonstrate the feasibility and practicality of a new objective standard-setting method for determining the pass/fail cut-off score from borderline grades. Three methods for setting up pass/fail cut-off scores were compared: the Regression Method, the Borderline Group Method, and the new Objective Borderline Method (OBM). Using Year 5 students' OSCE results from one medical school we established the pass/fail cut-off scores by the abovementioned three methods. The comparison indicated that the pass/fail cut-off scores generated by the OBM were similar to those generated by the more established methods (0.840 ≤ r ≤ 0.998; p < .0001). Based on theoretical and empirical analysis, we suggest that the OBM has advantages over existing methods in that it combines objectivity, realism, robust empirical basis and, no less importantly, is simple to use.
SAR-based change detection using hypothesis testing and Markov random field modelling
NASA Astrophysics Data System (ADS)
Cao, W.; Martinis, S.
2015-04-01
The objective of this study is to automatically detect changed areas caused by natural disasters from bi-temporal co-registered and calibrated TerraSAR-X data. The technique in this paper consists of two steps: Firstly, an automatic coarse detection step is applied based on a statistical hypothesis test for initializing the classification. The original analytical formula as proposed in the constant false alarm rate (CFAR) edge detector is reviewed and rewritten in a compact form of the incomplete beta function, which is a builtin routine in commercial scientific software such as MATLAB and IDL. Secondly, a post-classification step is introduced to optimize the noisy classification result in the previous step. Generally, an optimization problem can be formulated as a Markov random field (MRF) on which the quality of a classification is measured by an energy function. The optimal classification based on the MRF is related to the lowest energy value. Previous studies provide methods for the optimization problem using MRFs, such as the iterated conditional modes (ICM) algorithm. Recently, a novel algorithm was presented based on graph-cut theory. This method transforms a MRF to an equivalent graph and solves the optimization problem by a max-flow/min-cut algorithm on the graph. In this study this graph-cut algorithm is applied iteratively to improve the coarse classification. At each iteration the parameters of the energy function for the current classification are set by the logarithmic probability density function (PDF). The relevant parameters are estimated by the method of logarithmic cumulants (MoLC). Experiments are performed using two flood events in Germany and Australia in 2011 and a forest fire on La Palma in 2009 using pre- and post-event TerraSAR-X data. The results show convincing coarse classifications and considerable improvement by the graph-cut post-classification step.
Vähä-Ypyä, Henri; Vasankari, Tommi; Husu, Pauliina; Mänttäri, Ari; Vuorimaa, Timo; Suni, Jaana; Sievänen, Harri
2015-01-01
Our recent study of three accelerometer brands in various ambulatory activities showed that the mean amplitude deviation (MAD) of the resultant acceleration signal performed best in separating different intensity levels and provided excellent agreement between the three devices. The objective of this study was to derive a regression model that estimates oxygen consumption (VO2) from MAD values and validate the MAD-based cut-points for light, moderate and vigorous locomotion against VO2 within a wide range of speeds. 29 participants performed a pace-conducted non-stop test on a 200 m long indoor track. The initial speed was 0.6 m/s and it was increased by 0.4 m/s every 2.5 minutes until volitional exhaustion. The participants could freely decide whether they preferred to walk or run. During the test they carried a hip-mounted tri-axial accelerometer and mobile metabolic analyzer. The MAD was calculated from the raw acceleration data and compared to directly measured incident VO2. Cut-point between light and moderate activity was set to 3.0 metabolic equivalent (MET, 1 MET = 3.5 ml · kg-1 · min-1) and between moderate and vigorous activity to 6.0 MET as per standard use. The MAD and VO2 showed a very strong association. Within individuals, the range of r values was from 0.927 to 0.991 providing the mean r = 0.969. The optimal MAD cut-point for 3.0 MET was 91 mg (milligravity) and 414 mg for 6.0 MET. The present study showed that the MAD is a valid method in terms of the VO2 within a wide range of ambulatory activities from slow walking to fast running. Being a device-independent trait, the MAD facilitates directly comparable, accurate results on the intensity of physical activity with all accelerometers providing tri-axial raw data.
a Framework for AN Automatic Seamline Engine
NASA Astrophysics Data System (ADS)
Al-Durgham, M.; Downey, M.; Gehrke, S.; Beshah, B. T.
2016-06-01
Seamline generation is a crucial last step in the ortho-image mosaicking process. In particular, it is required to convolute residual geometric and radiometric imperfections that stem from various sources. In particular, temporal differences in the acquired data will cause the scene content and illumination conditions to vary. These variations can be modelled successfully. However, one is left with micro-differences that do need to be considered in seamline generation. Another cause of discrepancies originates from the rectification surface as it will not model the actual terrain and especially human-made objects perfectly. Quality of the image orientation will also contribute to the overall differences between adjacent ortho-rectified images. Our approach takes into consideration the aforementioned differences in designing a seamline engine. We have identified the following essential behaviours of the seamline in our engine: 1) Seamlines must pass through the path of least resistance, i.e., overlap areas with low radiometric differences. 2) Seamlines must not intersect with breaklines as that will lead to visible geometric artefacts. And finally, 3), shorter seamlines are generally favourable; they also result in faster operator review and, where necessary, interactive editing cycles. The engine design also permits alteration of the above rules for special cases. Although our preliminary experiments are geared towards line imaging systems (i.e., the Leica ADS family), our seamline engine remains sensor agnostic. Hence, our design is capable of mosaicking images from various sources with minimal effort. The main idea behind this engine is using graph cuts which, in spirit, is based of the max-flow min-cut theory. The main advantage of using graph cuts theory is that the generated solution is global in the energy minimization sense. In addition, graph cuts allows for a highly scalable design where a set of rules contribute towards a cost function which, in turn, influences the path of minimum resistance for the seamlines. In this paper, the authors present an approach for achieving quality seamlines relatively quickly and with emphasis on generating truly seamless ortho-mosaics.
ERIC Educational Resources Information Center
Oladele, Babatunde
2017-01-01
The aim of the current study is to analyse the 2014 Post UTME scores of candidates in the university of Ibadan towards the establishment of cut off using two methods of standard settings. Prospective candidates who seek admission to higher institution are often denied admission through the Post UTME exercise. There is no single recommended…
NASA Astrophysics Data System (ADS)
Fishkova, T. Ya.
2018-01-01
An optimal set of geometric and electrical parameters of a high-aperture electrostatic charged-particle spectrograph with a range of simultaneously recorded energies of E/ E min = 1-50 has been found by computer simulation, which is especially important for the energy analysis of charged particles during fast processes in various materials. The spectrograph consists of two coaxial electrodes with end faces closed by flat electrodes. The external electrode with a conical-cylindrical form is cut into parts with potentials that increase linearly, except for the last cylindrical part, which is electrically connected to the rear end electrode. The internal cylindrical electrode and the front end electrode are grounded. In the entire energy range, the system is sharply focused on the internal cylindrical electrode, which provides an energy resolution of no worse than 3 × 10-3.
Honl, M; Rentzsch, R; Müller, G; Brandt, C; Bluhm, A; Hille, E; Louis, H; Morlock, M
2000-01-01
Water-jet cutting techniques have been used in industrial applications for many different materials. Recently these techniques have been developed into a revolutionary cutting tool for soft tissues in visceral surgery. The present study investigates the usage of this cutting technology for the revision surgery of endoprostheses. In the first part of the study, samples of bovine bone and acrylic bone cement (PMMA) were cut using an industrial jet cutting device with pure water. Below 400 bar, only PMMA was cut; above 400 bar, bone was also cut, but only pressures above 800 bar resulted in clinically useful rates of material removal (cut depth 2. 4 mm at 10 mm/min traverse speed). In the second part of the study, the effect of adding biocompatible abrasives to the water in order to reduce the required pressure was investigated, resulting in a significantly higher removal of material. At 600 bar, PMMA was cut 5. 2 mm deep with plain water and 15.2 mm deep with added abrasives. The quality of the cuts was increased by the abrasive. Though there was no clear selectivity between bone and PMMA any more, the rate of material removal at similar pressures was significantly higher for PMMA than for bone (600 bar: 1.6 mm cut depth for bone samples, 15.2 mm for PMMA). The measured cut depths with either method were not influenced by a change of the cutting direction with respect to the main direction of the osteons in the bone. However, a reduction of the jet surface angle (90 degrees to 23 degrees ) resulted for bone in a significantly lower cut depth at 600 bar (plain water: 0.62 mm vs. 0.06 mm; abrasive: 1.61 mm vs. 0.60 mm). The laboratory experiments indicate that abrasive water jets may be suitable for cutting biomaterials like bone and bone cement. Copyright 2000 John Wiley & Sons, Inc.
Raise cutting diameters for increased returns
H. Clay Smith; G. R., Jr. Trimble; Paul S. DeBald
1979-01-01
Diameter-limit cutting is widely used to harvest logs in eastern hardwoods. Studies show that cutting limits are often set so low that they sacrifice financial returns. The value of lumber cut from logs is largely dependent on the diameter, grade, and tree species. As tree size increases so does the proportion of higher grade lumber, and this is reflected in improved...
Mahmood, S; Basarab, J A; Dixon, W T; Bruce, H L
2016-11-01
Previous research has suggested that cattle predisposed to dark cutting can be identified from live animal or carcass characteristics. This hypothesis was tested using production and phenotype data from an existing data set collected from heifers (n=467) on study at three farms. Carcasses in the data set graded Canada AAA (n=136), AA (n=296), A (n=14), and B4 (dark cutting, n=21). Farm was identified as significant (P=0.0268) by CATMOD analysis and slaughter weight and carcass weight accounted for the variation in dark cutting frequency across the farms. Analysis of variance indicated that dark cutting heifers had reduced weight at weaning (P<0.0001) and at slaughter (P<0.0001), and produced reduced weight carcasses (P<0.0001). Results of logistic regression indicated that the probability of dark cutting was decreased in heifers slaughtered at live weight greater than 550kg and in carcasses weighing greater than 325kg. Copyright © 2016 Elsevier Ltd. All rights reserved.
A Low-Pressure Oxygen Storage System for Oxygen Supply in Low-Resource Settings.
Rassool, Roger P; Sobott, Bryn A; Peake, David J; Mutetire, Bagayana S; Moschovis, Peter P; Black, Jim Fp
2017-12-01
Widespread access to medical oxygen would reduce global pneumonia mortality. Oxygen concentrators are one proposed solution, but they have limitations, in particular vulnerability to electricity fluctuations and failure during blackouts. The low-pressure oxygen storage system addresses these limitations in low-resource settings. This study reports testing of the system in Melbourne, Australia, and nonclinical field testing in Mbarara, Uganda. The system included a power-conditioning unit, a standard oxygen concentrator, and an oxygen store. In Melbourne, pressure and flows were monitored during cycles of filling/emptying, with forced voltage fluctuations. The bladders were tested by increasing pressure until they ruptured. In Mbarara, the system was tested by accelerated cycles of filling/emptying and then run on grid power for 30 d. The low-pressure oxygen storage system performed well, including sustaining a pressure approximately twice the standard working pressure before rupture of the outer bag. Flow of 1.2 L/min was continuously maintained to a simulated patient during 30 d on grid power, despite power failures totaling 2.9% of the total time, with durations of 1-176 min (mean 36.2, median 18.5). The low-pressure oxygen storage system was robust and durable, with accelerated testing equivalent to at least 2 y of operation revealing no visible signs of imminent failure. Despite power cuts, the system continuously provided oxygen, equivalent to the treatment of one child, for 30 d under typical power conditions for sub-Saharan Africa. The low-pressure oxygen storage system is ready for clinical field trials. Copyright © 2017 by Daedalus Enterprises.
Stewart, Barclay T; Gyedu, Adam; Quansah, Robert; Addo, Wilfred Larbi; Afoko, Akis; Agbenorku, Pius; Amponsah-Manu, Forster; Ankomah, James; Appiah-Denkyira, Ebenezer; Baffoe, Peter; Debrah, Sam; Donkor, Peter; Dorvlo, Theodor; Japiong, Kennedy; Kushner, Adam L; Morna, Martin; Ofosu, Anthony; Oppong-Nketia, Victor; Tabiri, Stephen; Mock, Charles
2016-01-01
Prospective clinical audit of trauma care improves outcomes for the injured in high-income countries (HICs). However, equivalent, context-appropriate audit filters for use in low- and middle-income country (LMIC) district-level hospitals have not been well established. We aimed to develop context-appropriate trauma care audit filters for district-level hospitals in Ghana, was well as other LMICs more broadly. Consensus on trauma care audit filters was built between twenty panellists using a Delphi technique with four anonymous, iterative surveys designed to elicit: (i) trauma care processes to be measured; (ii) important features of audit filters for the district-level hospital setting; and (iii) potentially useful filters. Filters were ranked on a scale from 0 to 10 (10 being very useful). Consensus was measured with average percent majority opinion (APMO) cut-off rate. Target consensus was defined a priori as: a median rank of ≥9 for each filter and an APMO cut-off rate of ≥0.8. Panellists agreed on trauma care processes to target (e.g. triage, phases of trauma assessment, early referral if needed) and specific features of filters for district-level hospital use (e.g. simplicity, unassuming of resource capacity). APMO cut-off rate increased successively: Round 1--0.58; Round 2--0.66; Round 3--0.76; and Round 4--0.82. After Round 4, target consensus on 22 trauma care and referral-specific filters was reached. Example filters include: triage--vital signs are recorded within 15 min of arrival (must include breathing assessment, heart rate, blood pressure, oxygen saturation if available); circulation--a large bore IV was placed within 15 min of patient arrival; referral--if referral is activated, the referring clinician and receiving facility communicate by phone or radio prior to transfer. This study proposes trauma care audit filters appropriate for LMIC district-level hospitals. Given the successes of similar filters in HICs and obstetric care filters in LMICs, the collection and reporting of prospective trauma care audit filters may be an important step towards improving care for the injured at district-level hospitals in LMICs. Copyright © 2015 Elsevier Ltd. All rights reserved.
Hoofs, H.; Jansen, N. W. H.; Mohren, D. C. L.; Jansen, M. W. J.; Kant, I. J.
2015-01-01
Background The Strength and Difficulties Questionnaire (SDQ) is a screening instrument for psychosocial problems in children and adolescents, which is applied in “individual” and “collective” settings. Assessment in the individual setting is confidential for clinical applications, such as preventive child healthcare, while assessment in the collective setting is anonymous and applied in (epidemiological) research. Due to administration differences between the settings it remains unclear whether results and conclusions actually can be used interchangeably. This study therefore aims to investigate whether the SDQ is invariant across settings. Methods Two independent samples were retrieved (mean age = 14.07 years), one from an individual setting (N = 6,594) and one from a collective setting (N = 4,613). The SDQ was administered in the second year of secondary school in both settings. Samples come from the same socio-geographic population in the Netherlands. Results Confirmatory factor analysis showed that the SDQ was measurement invariant/equivalent across settings and gender. On average, children in the individual setting scored lower on total difficulties (mean difference = 2.05) and the psychosocial problems subscales compared to those in the collective setting. This was also reflected in the cut-off points for caseness, defined by the 90th percentiles, which were lower in the individual setting. Using cut-off points from the collective in the individual setting therefore resulted in a small number of cases, 2 to 3%, while ∼10% is expected. Conclusion The SDQ has the same connotation across the individual and collective setting. The observed structural differences regarding the mean scores, however, undermine the validity of the cross-use of absolute SDQ-scores between these settings. Applying cut-off scores from the collective setting in the individual setting could, therefore, result in invalid conclusions and potential misuse of the instrument. To correctly apply cut-off scores these should be retrieved from the applied setting. PMID:25886464
Thormar, H; Hilmarsson, H
2010-09-01
Contamination in the kitchen with foodborne bacteria is a risk factor in human exposure to these pathogens, an important route being transfer of bacteria from contaminated cutting boards and other surfaces to humans. The aim of this study was to test microbicidal emulsions of glycerol monocaprate (monocaprin) against Campylobacter on contaminated cutting boards. Plastic and wooden cutting boards, soiled with meat juice heavily contaminated with Campylobacter, were treated for 2 min with emulsions of monocaprin (MC) made in water or in buffer at low pH. Viable Campylobacter counts were reduced below the detectable level on plastic board surfaces after treatment with MC emulsions with or without 1.25% washing-up liquids (WUL). The counts were also greatly reduced on wooden boards (P < 0.05). Monocaprin emulsions and mixtures of MC emulsions and WUL may be useful as sanitizers/disinfectants in kitchens and in other food preparing and processing facilities. Cleaning with MC emulsions with or without WUL may reduce the risk of human exposure to Campylobacter.
Yeoh, Wei Keat; Ali, Asgar
2017-02-01
Ultrasound treatment at different power output (0, 25 and 29W) and exposure time (10 and 15min) was used to investigate its effect on the phenolic metabolism enzymes, total phenolic content and antioxidant capacity of fresh-cut pineapple. Following ultrasound treatment at 25 and 29W, the activity of phenylalanine ammonia lyase (PAL) was increased significantly (P<0.05) by 2.0 and 1.9-fold, when compared to control. Meanwhile, both the activity of polyphenol oxidase (PPO) and polyphenol peroxidase (POD) in fresh-cut pineapple was significantly (P<0.05) lower than control upon subjected to ultrasound treatment. In the present study, induction of PAL was found to significantly (P<0.001) correlate with higher total phenolic content and thus higher antioxidant capacity in fresh-cut pineapple. Results suggest that hormetic dosage of ultrasound treatment can enhance the activity of PAL and total phenolic content and hence the total antioxidant capacity to encounter with oxidative stress. Copyright © 2016. Published by Elsevier Ltd.
Zhang, Chenxing; Bald, Matthew; Tang, Maolong; Li, Yan; Huang, David
2015-01-01
PURPOSE To evaluate interface quality of different corneal lamellar–cut depths with the femtosecond laser and determine a feasible range of depth for femtosecond laser–assisted lamellar anterior keratoplasty. SETTING Casey Eye Institute, Portland, Oregon, USA. DESIGN Experimental study. METHODS Full lamellar cuts were made on 20 deepithelialized human cadaver corneas using the femtosecond laser. The cut depth was 17% to 21% (100 μm), 31%, 35%, 38% to 40%, and 45% to 48% of the central stromal thickness. Scanning electron microscopy images of cap and bed surfaces were subjectively graded for ridge and roughness using a scale of 1 to 5 (1 = best). The graft–host match was evaluated by photography and optical coherence tomography in a simulated procedure. RESULTS The ridge score was correlated with the cut depth (P = .0078, R = 0.58) and better correlated with the percentage cut depth (P = .00024, R = 0.73). The shallowest cuts had the least ridges (score 1.25). The 31% cut depth produced significantly less ridges (score 2.15) than deeper cuts. The roughness score ranged from 2.19 to 3.08 for various depths. A simulated procedure using a 100 μm host cut and a 177 μm (31%) graft had a smooth interface and flush anterior junction using an inverted side-cut design. CONCLUSIONS The femtosecond laser produced more ridges in deeper lamellar cuts. A depth setting of 31% stromal thickness might produce adequate surface quality for femtosecond laser–assisted lamellar anterior keratoplasty. The inverted side-cut design produced good edge apposition even when the graft was thicker than the host lamellar–cut depth. PMID:25747165
Wille, Sarah M R; Di Fazio, Vincent; Toennes, Stefan W; van Wel, Janelle H P; Ramaekers, Johannes G; Samyn, Nele
2015-03-01
Oral fluid (OF) is potentially useful to detect driving under the influence of drugs because of its ease of sampling. While cannabis is the most prevalent drug in Europe, sensitivity issues for Δ(9) -tetrahydrocannabinol (THC) screening and problems during OF collection are observed. The ability of a recently improved OF screening device - the DrugWipe5S(®) , to detect recent THC use in chronic cannabis smokers, was studied. Ten subjects participated in a double-blind placebo-controlled study. The subjects smoked two subsequent doses of THC; 300 µg/kg and 150 µg/kg with a pause of 75 min using a Volcano vapourizer. DrugWipe5S(®) screening and OF collection using the Quantisal™ device were performed at baseline, 5 min after each administration and 80 min after the last inhalation. Blood samples were drawn simultaneously. The screening devices (n = 80) were evaluated visually after 8 min, while the corresponding OF and serum samples were analyzed respectively with ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) or gas chromatography-mass spectrometry (GC-MS). Neat OF THC concentrations ranged from 12 361 ng/g 5 min after smoking down to 34 ng/g 80 min later. Under placebo conditions, a median THC concentration of 8 ng/g OF (0-746 ng/g) and < 1 ng/ mL serum (0-7.8 ng/mL) was observed. The DrugWipe5S(®) was positive just after smoking (90%); however, sensitivity rapidly decreased within 1.5 h (50%). Sensitivity of DrugWipe5S(®) should be improved. As chronic cannabis users have high residual THC concentrations in their serum and OF, confirmation cut-offs should be set according to the aim of detecting recent drug use or establishing zero tolerance. Copyright © 2014 John Wiley & Sons, Ltd.
The complexity of identifying Ryu-Takayanagi surfaces in AdS 3/CFT 2
Bao, Ning; Chatwin-Davies, A.
2016-11-07
Here, we present a constructive algorithm for the determination of Ryu-Takayanagi surfaces in AdS 3/CFT 2 which exploits previously noted connections between holographic entanglement entropy and max-flow/min-cut. We then characterize its complexity as a polynomial time algorithm.
Control of spoiler Pseudomonas spp. on fresh cut vegetables by neutral electrolyzed water.
Pinto, Loris; Ippolito, Antonio; Baruzzi, Federico
2015-09-01
In the present study, we evaluated the antimicrobial activity of neutral electrolyzed water (NEW) against 14 strains of spoilage Pseudomonas of fresh cut vegetables under cold storage. The NEW, produced from solutions of potassium and sodium chloride, and sodium bicarbonate developed up to 4000 mg/L of free chlorine, depending on the salt and relative concentration used. The antimicrobial effect of the NEW was evaluated against different bacterial strains at 10(5) cells/ml, with different combinations of free chlorine concentration/contact time; all concentrations above 100 mg/L, regardless of the salt used, were found to be bactericidal already after 2 min. When catalogna chicory and lettuce leaves were dipped for 5 min in diluted NEW, microbial loads of mesophilic bacteria and Enterobacteriaceae were reduced on average of 1.7 log cfu/g. In addition, when lettuce leaves were dipped in a cellular suspension of the spoiler Pseudomonas chicorii I3C strain, diluted NEW was able to reduce Pseudomonas population of about 1.0 log cfu/g. Thanks to its high antimicrobial activity against spoilage microorganisms, and low cost of operation, the application of cycles of electrolysis to the washing water looks as an effective tool in controlling fresh cut vegetable microbial spoilage contamination occurring during washing steps. Copyright © 2015 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gusri, A. I.; Che Hassan, C. H.; Jaharah, A. G.
2011-01-17
The performance of Chemical Vapor Deposition (CVD) carbide insert with ISO designation of CCMT 12 04 04 LF, when turning titanium alloys was investigated. There were four layers of coating materials for this insert i.e.TiN-Al2O3-TiCN-TiN. The insert performance was evaluated based on the insert's edge resistant towards the machining parameters used at high cutting speed range of machining Ti-6Al-4V ELI. Detailed study on the wear mechanism at the cutting edge of CVD carbide tools was carried out at cutting speed of 55-95 m/min, feed rate of 0.15-0.35 mm/rev and depth of cut of 0.10-0.20 mm. Wear mechanisms such as abrasivemore » and adhesive were observed on the flank face. Crater wear due to diffusion was also observed on the rake race. The abrasive wear occurred more at nose radius and the fracture on tool were found at the feed rate of 0.35 mm/rev and the depth of cut of 0.20 mm. The adhesion wear takes place after the removal of the coating or coating delaminating. Therefore, adhesion or welding of titanium alloy onto the flank and rake faces demonstrates a strong bond at the workpiece-tool interface.« less
NASA Astrophysics Data System (ADS)
Gusri, A. I.; Che Hassan, C. H.; Jaharah, A. G.
2011-01-01
The performance of Chemical Vapor Deposition (CVD) carbide insert with ISO designation of CCMT 12 04 04 LF, when turning titanium alloys was investigated. There were four layers of coating materials for this insert i.e.TiN-Al2O3-TiCN-TiN. The insert performance was evaluated based on the insert's edge resistant towards the machining parameters used at high cutting speed range of machining Ti-6Al-4V ELI. Detailed study on the wear mechanism at the cutting edge of CVD carbide tools was carried out at cutting speed of 55-95 m/min, feed rate of 0.15-0.35 mm/rev and depth of cut of 0.10-0.20 mm. Wear mechanisms such as abrasive and adhesive were observed on the flank face. Crater wear due to diffusion was also observed on the rake race. The abrasive wear occurred more at nose radius and the fracture on tool were found at the feed rate of 0.35 mm/rev and the depth of cut of 0.20 mm. The adhesion wear takes place after the removal of the coating or coating delaminating. Therefore, adhesion or welding of titanium alloy onto the flank and rake faces demonstrates a strong bond at the workpiece-tool interface.
A minimization method on the basis of embedding the feasible set and the epigraph
NASA Astrophysics Data System (ADS)
Zabotin, I. Ya; Shulgina, O. N.; Yarullin, R. S.
2016-11-01
We propose a conditional minimization method of the convex nonsmooth function which belongs to the class of cutting-plane methods. During constructing iteration points a feasible set and an epigraph of the objective function are approximated by the polyhedral sets. In this connection, auxiliary problems of constructing iteration points are linear programming problems. In optimization process there is some opportunity of updating sets which approximate the epigraph. These updates are performed by periodically dropping of cutting planes which form embedding sets. Convergence of the proposed method is proved, some realizations of the method are discussed.
Whiting, Penny; Birnie, Kate; Sterne, Jonathan A C; Jameson, Catherine; Skinner, Rod; Phillips, Bob
2018-05-01
We conducted a systematic review and individual patient data (IPD) meta-analysis to examine the utility of cystatin C for evaluation of glomerular function in children with cancer. Eligible studies evaluated the accuracy of cystatin C for detecting poor renal function in children undergoing chemotherapy. Study quality was assessed using QUADAS-2. Authors of four studies shared IPD. We calculated the correlation between log cystatin C and GFR stratified by study and measure of cystatin C. We dichotomized the reference standard at GFR 80 ml/min/1.73m 2 and stratified cystatin C at 1 mg/l, to calculate sensitivity and specificity in each study and according to age group (0-4, 5-12, and ≥ 13 years). In sensitivity analyses, we investigated different GFR and cystatin C cut points. We used logistic regression to estimate the association of impaired renal function with log cystatin C and quantified diagnostic accuracy using the area under the ROC curve (AUC). Six studies, which used different test and reference standard thresholds, suggested that cystatin C has the potential to monitor renal function in children undergoing chemotherapy for malignancy. IPD data (504 samples, 209 children) showed that cystatin C has poor sensitivity (63%) and moderate specificity (89%), although use of a GFR cut point of < 60 ml/min/1.73m 2 (data only available from two of the studies) estimated sensitivity to be 92% and specificity 81.3%. The AUC for the combined data set was 0.890 (95% CI 0.826, 0.951). Diagnostic accuracy appeared to decrease with age. Cystatin C has better diagnostic accuracy than creatinine as a test for glomerular dysfunction in young people undergoing treatment for cancer. Diagnostic accuracy is not sufficient for it to replace current reference standards for predicting clinically relevant impairments that may alter dosing of important nephrotoxic agents.
Proficiency Standards and Cut-Scores for Language Proficiency Tests.
ERIC Educational Resources Information Center
Moy, Raymond H.
1984-01-01
Discusses the problems associated with "grading on a curve," the approach often used for standard setting on language proficiency tests. Proposes four main steps presented in the setting of a non-arbitrary cut-score. These steps not only establish a proficiency standard checked by external criteria, but also check to see that the test covers the…
Dray, Xavier; Donatelli, Gianfranco; Krishnamurty, Devi Mukkai; Dubcenco, Elena; Wroblewski, Ronald J; Assumpcao, Lia; Giday, Samuel A; Buscaglia, Jonathan M; Shin, Eun J; Magno, Priscilla; Pipitone, Laurie J; Marohn, Michael R; Kantsevoy, Sergey V; Kalloo, Anthony N
2010-09-01
Lasers 2-microm in wavelength offer efficient tissue cutting with limited thermal damage in biological tissue. To evaluate the dissection capabilities of a 2-microm continuous-wave laser for NOTES procedures. We conducted 18 acute animal experiments. Group 1 (three animals): transcolonic access to the peritoneal cavity (15-W transcolonic laser puncture, balloon dilation over the laser probe). Group 2 (six animals): transcolonic access with needle-knife puncture and balloon dilation. Group 3 (three animals): transgastric access to the peritoneal cavity (similar technique as group 1) followed by laser-assisted dissection of the kidney. In one animal of group 3, a therapeutic target (hematoma) was created by percutaneous puncture of the kidney. Group 4 (six animals): transgastric access (similar to the technique of group 2). Translumenal access to the peritoneal cavity was achieved in 2-3 min in group 1 (significantly shorter than with the needle-knife-assisted technique, 4-5 min, p=0.02) and in 7-10 min in group 3 (compared to 6-17 min in group 4, p=0.88). In group 3, laser dissection of the parietal peritoneum and of perinephric connective tissue allowed access to the retroperitoneum with complete removal of a blood collection in the animal with puncture trauma. Laser dissection demonstrated good maneuverability, clean and rapid cutting, and excellent hemostasis. Peritoneoscopy and necropsy showed no damage of targeted tissue and surrounding organs. The 2-microm continuous-wave laser system showed promising capabilities for highly precise and safe dissection during NOTES procedures.
Vision-based Nano Robotic System for High-throughput Non-embedded Cell Cutting
NASA Astrophysics Data System (ADS)
Shang, Wanfeng; Lu, Haojian; Wan, Wenfeng; Fukuda, Toshio; Shen, Yajing
2016-03-01
Cell cutting is a significant task in biology study, but the highly productive non-embedded cell cutting is still a big challenge for current techniques. This paper proposes a vision-based nano robotic system and then realizes automatic non-embedded cell cutting with this system. First, the nano robotic system is developed and integrated with a nanoknife inside an environmental scanning electron microscopy (ESEM). Then, the positions of the nanoknife and the single cell are recognized, and the distance between them is calculated dynamically based on image processing. To guarantee the positioning accuracy and the working efficiency, we propose a distance-regulated speed adapting strategy, in which the moving speed is adjusted intelligently based on the distance between the nanoknife and the target cell. The results indicate that the automatic non-embedded cutting is able to be achieved within 1-2 mins with low invasion benefiting from the high precise nanorobot system and the sharp edge of nanoknife. This research paves a way for the high-throughput cell cutting at cell’s natural condition, which is expected to make significant impact on the biology studies, especially for the in-situ analysis at cellular and subcellular scale, such as cell interaction investigation, neural signal transduction and low invasive cell surgery.
George, Dominic Soloman; Razali, Zuliana; Santhirasegaram, Vicknesha; Somasundram, Chandran
2015-02-01
The effects of ultraviolet (UV-C) and medium heat (70 °C) treatments on the quality of fresh-cut Chokanan mango and Josephine pineapple were investigated. Quality attributes included physicochemical properties (pH, titratable acidity, and total soluble solids), ascorbic acid content (vitamin C), antioxidant activity, as well as microbial inactivation. Consumers' acceptance was also investigated through sensory evaluation of the attributes (appearance, texture, aroma and taste). Furthermore, shelf-life study of samples stored at 4 ± 1 °C was conducted for 15 d. The fresh-cut fruits were exposed to UV-C for 0, 15, 30, and 60 min while heat treatments were carried out at 70 °C for 0, 5, 10 and 20 min. Both UV-C and medium heat treatments resulted in no significant changes to the physicochemical attributes of both fruits. The ascorbic acid content of UV-C treated fruits was unaffected; however, medium heat treatment resulted in deterioration of ascorbic acids in both fruits. The antioxidants were enhanced with UV-C treatment which could prove invaluable to consumers. Heat treatments on the other hand resulted in decreased antioxidant activities. Microbial count in both fruits was significantly reduced by both treatments. The shelf life of the fresh-cut fruits were also successfully extended to a maximum of 15 d following treatments. As for consumers' acceptance, UV-C treated fruits were the most accepted as compared to their heat-treated counterparts. The results obtained through this study support the use of UV-C treatment for better retention of quality, effective microbial inactivation and enhancement of health promoting compounds for the benefit of consumers. © 2015 Institute of Food Technologists®
Thermographic measurements of high-speed metal cutting
NASA Astrophysics Data System (ADS)
Mueller, Bernhard; Renz, Ulrich
2002-03-01
Thermographic measurements of a high-speed cutting process have been performed with an infrared camera. To realize images without motion blur the integration times were reduced to a few microseconds. Since the high tool wear influences the measured temperatures a set-up has been realized which enables small cutting lengths. Only single images have been recorded because the process is too fast to acquire a sequence of images even with the frame rate of the very fast infrared camera which has been used. To expose the camera when the rotating tool is in the middle of the camera image an experimental set-up with a light barrier and a digital delay generator with a time resolution of 1 ns has been realized. This enables a very exact triggering of the camera at the desired position of the tool in the image. Since the cutting depth is between 0.1 and 0.2 mm a high spatial resolution was also necessary which was obtained by a special close-up lens allowing a resolution of app. 45 microns. The experimental set-up will be described and infrared images and evaluated temperatures of a titanium alloy and a carbon steel will be presented for cutting speeds up to 42 m/s.
Ukuku, Dike O; Huang, Lihan; Sommers, Christopher
2015-07-01
For health reasons, people are consuming fresh-cut fruits with or without minimal processing and, thereby, exposing themselves to the risk of foodborne illness if such fruits are contaminated with bacterial pathogens. This study investigated survival and growth parameters of Escherichia coli O157:H7, Salmonella, Listeria monocytogenes, and aerobic mesophilic bacteria transferred from cantaloupe rind surfaces to fresh-cut pieces during fresh-cut preparation. All human bacterial pathogens inoculated on cantaloupe rind surfaces averaged ∼4.8 log CFU/cm(2), and the populations transferred to fresh-cut pieces before washing treatments ranged from 3 to 3.5 log CFU/g for all pathogens. A nisin-based sanitizer developed in our laboratory and chlorinated water at 1,000 mg/liter were evaluated for effectiveness in minimizing transfer of bacterial populations from cantaloupe rind surface to fresh-cut pieces. Inoculated and uninoculated cantaloupes were washed for 5 min before fresh-cut preparation and storage of fresh-cut pieces at 5 and 10°C for 15 days and at 22°C for 24 h. In fresh-cut pieces from cantaloupe washed with chlorinated water, only Salmonella was found (0.9 log CFU/g), whereas E. coli O157:H7 and L. monocytogenes were positive only by enrichment. The nisin-based sanitizer prevented transfer of human bacteria from melon rind surfaces to fresh-cut pieces, and the populations in fresh-cut pieces were below detection even by enrichment. Storage temperature affected survival and the growth rate for each type of bacteria on fresh-cut cantaloupe. Specific growth rates of E. coli O157:H7, Salmonella, and L. monocytogenes in fresh-cut pieces were similar, whereas the aerobic mesophilic bacteria grew 60 to 80 % faster and had shorter lag phases.
26 CFR 1.585-7 - Elective cut-off method of changing from the reserve method of section 585.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 26 Internal Revenue 7 2011-04-01 2009-04-01 true Elective cut-off method of changing from the... § 1.585-7 Elective cut-off method of changing from the reserve method of section 585. (a) General rule...)) may elect to use the cut-off method set forth in this section. Any such election must be made at the...
Nickley, Joyce; Pesce, Amadeo J; Krock, Kevin
2017-08-01
Cocaine is a common drug of abuse. To detect its use, a screening detection concentration for the cocaine metabolite benzoylecgonine is commonly set at 150 ng/mL and its confirmatory cut-off is set at 100 ng/mL. Studies have suggested that these cut-offs may be set too high, allowing some patients with this substance abuse problem to be missed or improperly monitored. With the advent of liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology it is possible to reliably detect and quantify lower concentrations of its metabolite benzoylecgonine as part of a larger drug panel. One purpose of the study was to establish if there was a significant increase in detection of cocaine use with a ten-fold more sensitive cut-off. A very sensitive dilute and shoot assay for benzoylecgonine was developed with a lower limit of quantitation of 5 ng/mL. Validation of the 5 ng/mL cut-off was achieved by plotting all the positive cocaine observations as a frequency distribution on a logarithmic scale. The number of positive results with measurable concentrations below the typical industry 100 ng/mL cut-off level but above the high sensitivity 5 ng/mL cut-off level was observed to be 51.9% of the observed positives. The lower cut-off also allowed a re-evaluation of the window of detection after cessation of use. It was observed to be between 17 and 22 days. © 2016 Precision Diagnostics, LLC. Drug Testing and Analysis published by John Wiley & Sons, Ltd. © 2016 Precision Diagnostics, LLC. Drug Testing and Analysis published by John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Okokpujie, Imhade Princess; Ikumapayi, Omolayo M.; Okonkwo, Ugochukwu C.; Salawu, Enesi Y.; Afolalu, Sunday A.; Dirisu, Joseph O.; Nwoke, Obinna N.; Ajayi, Oluseyi O.
2017-12-01
In recent machining operation, tool life is one of the most demanding tasks in production process, especially in the automotive industry. The aim of this paper is to study tool wear on HSS in end milling of aluminium 6061 alloy. The experiments were carried out to investigate tool wear with the machined parameters and to developed mathematical model using response surface methodology. The various machining parameters selected for the experiment are spindle speed (N), feed rate (f), axial depth of cut (a) and radial depth of cut (r). The experiment was designed using central composite design (CCD) in which 31 samples were run on SIEG 3/10/0010 CNC end milling machine. After each experiment the cutting tool was measured using scanning electron microscope (SEM). The obtained optimum machining parameter combination are spindle speed of 2500 rpm, feed rate of 200 mm/min, axial depth of cut of 20 mm, and radial depth of cut 1.0mm was found out to achieved the minimum tool wear as 0.213 mm. The mathematical model developed predicted the tool wear with 99.7% which is within the acceptable accuracy range for tool wear prediction.
Dai, Jianrong; Que, William
2004-12-07
This paper introduces a method to simultaneously minimize the leaf travel distance and the tongue-and-groove effect for IMRT leaf sequences to be delivered in segmental mode. The basic idea is to add a large enough number of openings through cutting or splitting existing openings for those leaf pairs with openings fewer than the number of segments so that all leaf pairs have the same number of openings. The cutting positions are optimally determined with a simulated annealing technique called adaptive simulated annealing. The optimization goal is set to minimize the weighted summation of the leaf travel distance and tongue-and-groove effect. Its performance was evaluated with 19 beams from three clinical cases; one brain, one head-and-neck and one prostate case. The results show that it can reduce the leaf travel distance and (or) tongue-and-groove effect; the reduction of the leaf travel distance reaches its maximum of about 50% when minimized alone; the reduction of the tongue-and-groove reaches its maximum of about 70% when minimized alone. The maximum reduction in the leaf travel distance translates to a 1 to 2 min reduction in treatment delivery time per fraction, depending on leaf speed. If the method is implemented clinically, it could result in significant savings in treatment delivery time, and also result in significant reduction in the wear-and-tear of MLC mechanics.
Consistency of Standard Setting in an Augmented State Testing System
ERIC Educational Resources Information Center
Lissitz, Robert W.; Wei, Hua
2008-01-01
In this article we address the issue of consistency in standard setting in the context of an augmented state testing program. Information gained from the external NRT scores is used to help make an informed decision on the determination of cut scores on the state test. The consistency of cut scores on the CRT across grades is maintained by forcing…
Setting Cut-Scores: A Critical Review of the Angoff and Modified Angoff Methods
ERIC Educational Resources Information Center
Ricker, Kathryn L.
2006-01-01
The purpose of this article is to review critically the Angoff (1971) and modified Angoff methods for setting cut-scores. The criteria used in this review were originally proposed by Berk (1986). The assumptions of the Angoff method and other current issues surrounding this method are also discussed. Recommendations are made for using the Angoff…
NASA Astrophysics Data System (ADS)
Maity, Kalipada; Pradhan, Swastik
2018-04-01
In this study, machining of titanium alloy (grade 5) is carried out using MT-CVD coated cutting tool. Titanium alloys possess superior strength-to-weight ratio with good corrosion resistance. Most of the industries used titanium alloy for the manufacturing of various types of lightweight components. The parts made from Ti-6Al-4V largely used in aerospace, biomedical, automotive and marine sectors. The conventional machining of this material is very difficult, due to low thermal conductivity and high chemical reactivity properties. To achieve a good surface finish with minimum tool wear of cutting tool, the machining is carried out using MT-CVD coated cutting tool. The experiment is carried out using of Taguchi L27 array layout with three cutting variables and levels. To find out the optimum parametric setting desirability function analysis (DFA) approach is used. The analysis of variance is studied to know the percentage contribution of each cutting variables. The optimum parametric setting results calculated from DFA were validated through the confirmation test.
Kanz, K-G; Huber-Wagner, S; Lefering, R; Kay, M; Qvick, M; Biberthaler, P; Mutschler, W
2006-04-01
The surgical treatment capacity of a hospital constitutes a significant restriction in the capability to deal with critically injured patients from multiple or mass casualty incidents (MCI). With regard to the time needed for life-saving operative interventions there are no basic reference values available in the literature, which can aid in detailed planning for management of mass casualty incidents. The data of 20,815 trauma patients, recorded in the trauma registry hosted by the German Association for Trauma Surgery DGU, were analyzed to extract the median duration of life-saving surgical interventions carried out in an operating theatre. Inclusion criteria were an ISS > or = 16 and the performance of relevant ICPM coded procedures within 6 h after trauma room admission. Orthopedic procedures as well as the placement of ICP catheters and chest tubes or performance of laparoscopies were not included. Complete data sets with the required variables were available from 9,988 trauma patients with an ISS > or = 16, and included 7,907 interventions that took place within 6 h after hospital admission. From among 1,228 patients 1,793 operations could be identified as relevant life-saving emergency operations. Acute injury to the abdomen was the major cause accounting for 54.1% of all emergency surgical procedures with a median intervention duration of 137 min followed by head injuries accounting for 26.3% with a median duration of 110 min. Interventions in the pelvis amounted to 11.5% taking an average of 136 min, 5.0% were in the thorax requiring 91 min and 3.1% major amputations with 142 min. The average cut to suture time for all emergency surgical interventions was 130 min. A prerequisite for estimating the surgical operation capacity for critically injured patients of an MCI is the number of OR teams available during and outside of the normal working hours of the hospital. The average operation time of 130 min calculated from investigation of 1,793 emergency life-saving surgical procedures provides a realistic guideline. Used in combination with the number of available OR teams the prospective treatment capacity can be estimated and projected into an actual incident admission capacity. The identification and numerical value of such significant variables are the basis for operations research and realistic planning in emergency and disaster medicine.
NASA Astrophysics Data System (ADS)
Vitshas, A. A.; Zelentsov, A. G.; Lopota, V. A.; Menakhin, V. P.; Panchenko, V. P.; Soroka, A. M.
2014-02-01
The results of the experimental and theoretical investigations aimed at determining the characteristics and features of precision slot cutting with a large number of calibers in sheets of low-carbon steel using the radiation of a single-mode fiber laser with pulse power up to 1 kW are presented. The description of the experimental installation, performance conditions of investigations, and variable parameters are described. Precision cutting of low-carbon steel up to 10 mm with the number of calibers ranging from 30 to 70 at a slot width of ≈60 μm is performed for the first time. Such cutting occurs only in the pulsed-periodic mode using single-mode radiation with a pulse duration of 2-3 ms, a pulse ratio of 2-4, and oxygen, whose influence differs in principle both in various cut regions over the sheet thickness and from cutting with a CO2 laser. The cutting velocity (100-50 mm/min) of sheet steel up to thicknesses of 10 mm with deep channeling, roughness parameters, hardness of the cut surface, which insignificantly (by ≈20%) exceeds the hardness of untreated steel, the phase structure of steel, and the scales of their varying inside metal are measured. The efficiency (≈3%) of precision cutting and the efficiency of transportation of radiation (25%) in large-caliber slot orifices in the "waveguide" mode are determined by the experimental data. The useful specific energy contribution of the laser radiation is w l = N l/( hbv) ≈ 2 × 1012 J/m2 for all studied thicknesses of sheet samples accurate to 20%. A qualitative model of the laser-oxygen precision cutting with deep channeling, which explains the cyclic and interrupting character of cutting and necessity of using oxygen as the cutting gas, is proposed.
Rooting response of azalea cultivars to hot water treatment used for pathogen conrol
USDA-ARS?s Scientific Manuscript database
Submerging terminal leafy cuttings of Rhododendron L. 'Gumpo White' ('Gumpo White' azalea) in 50 °C water for 21 min was previously shown to eliminate binucleate Rhizoctonia species, the cause of azalea web blight, from plant tissues. Prior to considering commercial use of this practice, a better un...
The mechanism of ethanol treatment on inhibiting lettuce enzymatic browning and microbial growth
USDA-ARS?s Scientific Manuscript database
Tissue browning of fresh-cut lettuce greatly affects its quality and consumers’ appreciation. This study investigated the effects of ethanol treatment on enzymatic browning and natural microflora growth of lettuce stem discs. After treated with 20% ethanol for 2 min and then drained by a spinner, le...
A characterization of linearly repetitive cut and project sets
NASA Astrophysics Data System (ADS)
Haynes, Alan; Koivusalo, Henna; Walton, James
2018-02-01
For the development of a mathematical theory which can be used to rigorously investigate physical properties of quasicrystals, it is necessary to understand regularity of patterns in special classes of aperiodic point sets in Euclidean space. In one dimension, prototypical mathematical models for quasicrystals are provided by Sturmian sequences and by point sets generated by substitution rules. Regularity properties of such sets are well understood, thanks mostly to well known results by Morse and Hedlund, and physicists have used this understanding to study one dimensional random Schrödinger operators and lattice gas models. A key fact which plays an important role in these problems is the existence of a subadditive ergodic theorem, which is guaranteed when the corresponding point set is linearly repetitive. In this paper we extend the one-dimensional model to cut and project sets, which generalize Sturmian sequences in higher dimensions, and which are frequently used in mathematical and physical literature as models for higher dimensional quasicrystals. By using a combination of algebraic, geometric, and dynamical techniques, together with input from higher dimensional Diophantine approximation, we give a complete characterization of all linearly repetitive cut and project sets with cubical windows. We also prove that these are precisely the collection of such sets which satisfy subadditive ergodic theorems. The results are explicit enough to allow us to apply them to known classical models, and to construct linearly repetitive cut and project sets in all pairs of dimensions and codimensions in which they exist. Research supported by EPSRC grants EP/L001462, EP/J00149X, EP/M023540. HK also gratefully acknowledges the support of the Osk. Huttunen foundation.
Implementation of Steiner point of fuzzy set.
Liang, Jiuzhen; Wang, Dejiang
2014-01-01
This paper deals with the implementation of Steiner point of fuzzy set. Some definitions and properties of Steiner point are investigated and extended to fuzzy set. This paper focuses on establishing efficient methods to compute Steiner point of fuzzy set. Two strategies of computing Steiner point of fuzzy set are proposed. One is called linear combination of Steiner points computed by a series of crisp α-cut sets of the fuzzy set. The other is an approximate method, which is trying to find the optimal α-cut set approaching the fuzzy set. Stability analysis of Steiner point of fuzzy set is also studied. Some experiments on image processing are given, in which the two methods are applied for implementing Steiner point of fuzzy image, and both strategies show their own advantages in computing Steiner point of fuzzy set.
DG TO FT - AUTOMATIC TRANSLATION OF DIGRAPH TO FAULT TREE MODELS
NASA Technical Reports Server (NTRS)
Iverson, D. L.
1994-01-01
Fault tree and digraph models are frequently used for system failure analysis. Both types of models represent a failure space view of the system using AND and OR nodes in a directed graph structure. Each model has its advantages. While digraphs can be derived in a fairly straightforward manner from system schematics and knowledge about component failure modes and system design, fault tree structure allows for fast processing using efficient techniques developed for tree data structures. The similarities between digraphs and fault trees permits the information encoded in the digraph to be translated into a logically equivalent fault tree. The DG TO FT translation tool will automatically translate digraph models, including those with loops or cycles, into fault tree models that have the same minimum cut set solutions as the input digraph. This tool could be useful, for example, if some parts of a system have been modeled using digraphs and others using fault trees. The digraphs could be translated and incorporated into the fault trees, allowing them to be analyzed using a number of powerful fault tree processing codes, such as cut set and quantitative solution codes. A cut set for a given node is a group of failure events that will cause the failure of the node. A minimum cut set for a node is any cut set that, if any of the failures in the set were to be removed, the occurrence of the other failures in the set will not cause the failure of the event represented by the node. Cut sets calculations can be used to find dependencies, weak links, and vital system components whose failures would cause serious systems failure. The DG TO FT translation system reads in a digraph with each node listed as a separate object in the input file. The user specifies a terminal node for the digraph that will be used as the top node of the resulting fault tree. A fault tree basic event node representing the failure of that digraph node is created and becomes a child of the terminal root node. A subtree is created for each of the inputs to the digraph terminal node and the root of those subtrees are added as children of the top node of the fault tree. Every node in the digraph upstream of the terminal node will be visited and converted. During the conversion process, the algorithm keeps track of the path from the digraph terminal node to the current digraph node. If a node is visited twice, then the program has found a cycle in the digraph. This cycle is broken by finding the minimal cut sets of the twice visited digraph node and forming those cut sets into subtrees. Another implementation of the algorithm resolves loops by building a subtree based on the digraph minimal cut sets calculation. It does not reduce the subtree to minimal cut set form. This second implementation produces larger fault trees, but runs much faster than the version using minimal cut sets since it does not spend time reducing the subtrees to minimal cut sets. The fault trees produced by DG TO FT will contain OR gates, AND gates, Basic Event nodes, and NOP gates. The results of a translation can be output as a text object description of the fault tree similar to the text digraph input format. The translator can also output a LISP language formatted file and an augmented LISP file which can be used by the FTDS (ARC-13019) diagnosis system, available from COSMIC, which performs diagnostic reasoning using the fault tree as a knowledge base. DG TO FT is written in C-language to be machine independent. It has been successfully implemented on a Sun running SunOS, a DECstation running ULTRIX, a Macintosh running System 7, and a DEC VAX running VMS. The RAM requirement varies with the size of the models. DG TO FT is available in UNIX tar format on a .25 inch streaming magnetic tape cartridge (standard distribution) or on a 3.5 inch diskette. It is also available on a 3.5 inch Macintosh format diskette or on a 9-track 1600 BPI magnetic tape in DEC VAX FILES-11 format. Sample input and sample output are provided on the distribution medium. An electronic copy of the documentation in Macintosh Microsoft Word format is provided on the distribution medium. DG TO FT was developed in 1992. Sun, and SunOS are trademarks of Sun Microsystems, Inc. DECstation, ULTRIX, VAX, and VMS are trademarks of Digital Equipment Corporation. UNIX is a registered trademark of AT&T Bell Laboratories. Macintosh is a registered trademark of Apple Computer, Inc. System 7 is a trademark of Apple Computers Inc. Microsoft Word is a trademark of Microsoft Corporation.
Sharma, Udit; Kataria, Vinod; Shekhawat, N S
2018-02-01
Tamarix aphylla (L.) Karst., a drought resistant halophyte tree, is an agroforestry species which can be used for reclamation of waterlogged saline and marginal lands. Due to very low seed viability and unsuitable conditions for seed germination, the tree is becoming rare in Indian Thar desert. Present study concerns the evaluation of aeroponics technique for vegetative propagation of T. aphylla . Effect of various exogenous auxins (indole-3-acetic acid, indole-3-butyric acid, naphthalene acetic acid) at different concentrations (0.0, 1.0, 2.0, 3.0, 5.0, 10.0 mg l -1 ) was examined for induction of adventitious rooting and other morphological features. Among all three auxins tested individually, maximum rooting response (79%) was observed with IBA 2.0 mg l -1 . However, stem cuttings treated with a combination of auxins (2.0 mg l -1 IBA and 1.0 mg l -1 IAA) for 15 min resulted in 87% of rooting response. Among three types of stem cuttings (apical shoot, newly sprouted cuttings, mature stem cuttings), maximum rooting (~ 90%) was observed on mature stem cuttings. Number of roots and root length were significantly higher in aeroponically rooted stem cuttings as compared to stem cuttings rooted in soil conditions. Successfully rooted and sprouted plants were transferred to polybags with 95% survival rate. This is the first report on aeroponic culture of Tamarix aphylla which can be utilized in agroforestry practices, marginal land reclamation and physiological studies.
Malau-Aduli, Bunmi Sherifat; Teague, Peta-Ann; D'Souza, Karen; Heal, Clare; Turner, Richard; Garne, David L; van der Vleuten, Cees
2017-12-01
A key issue underpinning the usefulness of the OSCE assessment to medical education is standard setting, but the majority of standard-setting methods remain challenging for performance assessment because they produce varying passing marks. Several studies have compared standard-setting methods; however, most of these studies are limited by their experimental scope, or use data on examinee performance at a single OSCE station or from a single medical school. This collaborative study between 10 Australian medical schools investigated the effect of standard-setting methods on OSCE cut scores and failure rates. This research used 5256 examinee scores from seven shared OSCE stations to calculate cut scores and failure rates using two different compromise standard-setting methods, namely the Borderline Regression and Cohen's methods. The results of this study indicate that Cohen's method yields similar outcomes to the Borderline Regression method, particularly for large examinee cohort sizes. However, with lower examinee numbers on a station, the Borderline Regression method resulted in higher cut scores and larger difference margins in the failure rates. Cohen's method yields similar outcomes as the Borderline Regression method and its application for benchmarking purposes and in resource-limited settings is justifiable, particularly with large examinee numbers.
Economic technology of laser cutting
NASA Astrophysics Data System (ADS)
Fedin, Alexander V.; Shilov, Igor V.; Vassiliev, Vladimir V.; Malov, Dmitri V.; Peskov, Vladimir N.
2000-02-01
The laser cutting of color metals and alloys by a thickness more than 2 mm has significant difficulties due to high reflective ability and large thermal conduction. We made it possible to raise energy efficiency and quality of laser cutting by using a laser processing system (LPS) consisting both of the YAG:Nd laser with passive Q-switching on base of LiF:F2- crystals and the CO2 laser. A distinctive feature of the LPS is that the radiation of different lasers incorporated in a coaxial beam has simultaneously high level of peak power (more than 400 kW in a TEM00 mode) and significant level of average power (up to 800 W in a TEM01 mode of the CO2 laser). The application of combined radiation for cutting of an aluminum alloy of D16 type made it possible to decrease the cutting energy threshold in 1.7 times, to increase depth of treatment from 2 up to 4 mm, and velocity from 0.015 up to 0.7 m/min, and also to eliminate application of absorptive coatings. At cutting of steels the velocity of treatment was doubled, and also an oxygen flow was eliminated from the technological process and replaced by the air. The obtained raise of energy efficiency and quality of cutting is explained by an essential size reducing of a formed penetration channel and by the shifting of a thermal cutting mode from melting to evaporation. The evaluation of interaction efficiency of a combined radiation was produced on the basis of non-stationary thermal-hydrodynamic model of a heating source moving as in the cutting direction, and also into the depth of material.
NASA Astrophysics Data System (ADS)
Khidhir, Basim A.; Mohamed, Bashir
2011-02-01
Machining parameters has an important factor on tool wear and surface finish, for that the manufacturers need to obtain optimal operating parameters with a minimum set of experiments as well as minimizing the simulations in order to reduce machining set up costs. The cutting speed is one of the most important cutting parameter to evaluate, it clearly most influences on one hand, tool life, tool stability, and cutting process quality, and on the other hand controls production flow. Due to more demanding manufacturing systems, the requirements for reliable technological information have increased. For a reliable analysis in cutting, the cutting zone (tip insert-workpiece-chip system) as the mechanics of cutting in this area are very complicated, the chip is formed in the shear plane (entrance the shear zone) and is shape in the sliding plane. The temperature contributed in the primary shear, chamfer and sticking, sliding zones are expressed as a function of unknown shear angle on the rake face and temperature modified flow stress in each zone. The experiments were carried out on a CNC lathe and surface finish and tool tip wear are measured in process. Machining experiments are conducted. Reasonable agreement is observed under turning with high depth of cut. Results of this research help to guide the design of new cutting tool materials and the studies on evaluation of machining parameters to further advance the productivity of nickel based alloy Hastelloy - 276 machining.
Code of Federal Regulations, 2011 CFR
2011-01-01
.... (1) Each cut sample shall be drawn from the bale after it is tied out following the ginning process.... (2) Where it is necessary to draw two sets of samples, a single cut should be made in each side of the bale, and the portion of cotton removed from each cut should be broken in half across the layers...
A calibration protocol for population-specific accelerometer cut-points in children.
Mackintosh, Kelly A; Fairclough, Stuart J; Stratton, Gareth; Ridgers, Nicola D
2012-01-01
To test a field-based protocol using intermittent activities representative of children's physical activity behaviours, to generate behaviourally valid, population-specific accelerometer cut-points for sedentary behaviour, moderate, and vigorous physical activity. Twenty-eight children (46% boys) aged 10-11 years wore a hip-mounted uniaxial GT1M ActiGraph and engaged in 6 activities representative of children's play. A validated direct observation protocol was used as the criterion measure of physical activity. Receiver Operating Characteristics (ROC) curve analyses were conducted with four semi-structured activities to determine the accelerometer cut-points. To examine classification differences, cut-points were cross-validated with free-play and DVD viewing activities. Cut-points of ≤ 372, >2160 and >4806 counts • min(-1) representing sedentary, moderate and vigorous intensity thresholds, respectively, provided the optimal balance between the related needs for sensitivity (accurately detecting activity) and specificity (limiting misclassification of the activity). Cross-validation data demonstrated that these values yielded the best overall kappa scores (0.97; 0.71; 0.62), and a high classification agreement (98.6%; 89.0%; 87.2%), respectively. Specificity values of 96-97% showed that the developed cut-points accurately detected physical activity, and sensitivity values (89-99%) indicated that minutes of activity were seldom incorrectly classified as inactivity. The development of an inexpensive and replicable field-based protocol to generate behaviourally valid and population-specific accelerometer cut-points may improve the classification of physical activity levels in children, which could enhance subsequent intervention and observational studies.
Szummer, Karolina; Evans, Marie; Carrero, Juan Jesus; Alehagen, Urban; Dahlström, Ulf; Benson, Lina; Lund, Lars H
2017-01-01
It is unknown how the creatinine-based renal function estimations differ for dose adjustment cut-offs and risk prediction in patients with heart failure. The renal function was similar with the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) (median 59 mL/min/1.73 m 2 , IQR 42 to 77) and Modification of Diet in Renal Disease Study (MDRD) (59 mL/min/1.73 m 2 , IQR 43 to 75) and slightly lower with the Cockcroft-Gault (CG) equation (57 mL/min, IQR 39 to 82). Across the commonly used renal function stages, the CKD-EPI and the MDRD classified patients into the same stage in 87.2% (kappa coefficient 0.83, p<0.001); the CKD-EPI and the CG equation agreed in 52.3% (kappa coefficient 0.39, p<0.001). Hence, a differing number of patients will receive dose adjustment depending on which formula is used as cut-off. The CG equation predicted worse prognosis better (c-statistics 0.740, 95% CI 0.734 to 0.746) than CKD-EPI (0.697, 95% CI 0.690 to 0.703, p<0.001) and MDRD (0.680, 95% CI 0.734 to 0.746). Using net reclassification improvement (NRI), the CG identified 12.8% more patients at higher risk of death as compared with the CKD-EPI equation. Patients registered in the Swedish Heart Failure Registry (n= 40 736) with standardised creatinine values between 2000 and 2012 had their renal function estimated with the CKD-EPI, the MDRD and the CG. Agreement between the formulas was compared for categories. Prediction of death was assessed with c-statistics and with NRI. The choice of renal function estimation formula has clinical implications and differing results at various cut-off levels. For prognosis, the CG predicts mortality better than the CKD-EPI and MDRD.
Szummer, Karolina; Evans, Marie; Carrero, Juan Jesus; Alehagen, Urban; Dahlström, Ulf; Benson, Lina; Lund, Lars H
2017-01-01
Background It is unknown how the creatinine-based renal function estimations differ for dose adjustment cut-offs and risk prediction in patients with heart failure. Method and results The renal function was similar with the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) (median 59 mL/min/1.73 m2, IQR 42 to 77) and Modification of Diet in Renal Disease Study (MDRD) (59 mL/min/1.73 m2, IQR 43 to 75) and slightly lower with the Cockcroft-Gault (CG) equation (57 mL/min, IQR 39 to 82). Across the commonly used renal function stages, the CKD-EPI and the MDRD classified patients into the same stage in 87.2% (kappa coefficient 0.83, p<0.001); the CKD-EPI and the CG equation agreed in 52.3% (kappa coefficient 0.39, p<0.001). Hence, a differing number of patients will receive dose adjustment depending on which formula is used as cut-off. The CG equation predicted worse prognosis better (c-statistics 0.740, 95% CI 0.734 to 0.746) than CKD-EPI (0.697, 95% CI 0.690 to 0.703, p<0.001) and MDRD (0.680, 95% CI 0.734 to 0.746). Using net reclassification improvement (NRI), the CG identified 12.8% more patients at higher risk of death as compared with the CKD-EPI equation. Patients registered in the Swedish Heart Failure Registry (n= 40 736) with standardised creatinine values between 2000 and 2012 had their renal function estimated with the CKD-EPI, the MDRD and the CG. Agreement between the formulas was compared for categories. Prediction of death was assessed with c-statistics and with NRI. Conclusion The choice of renal function estimation formula has clinical implications and differing results at various cut-off levels. For prognosis, the CG predicts mortality better than the CKD-EPI and MDRD. PMID:28761677
Substance P release in the spinal cord during the exercise pressor reflex in anaesthetized cats.
Wilson, L B; Fuchs, I E; Matsukawa, K; Mitchell, J H; Wall, P T
1993-01-01
1. The purpose of this study was to determine if static skeletal muscle contraction causes the release of substance P(SP) in the L7-dorsal horn region of the spinal cord. A laminectomy was performed to expose the spinal cord of alpha-chloralose anaesthetized cats. The L6 spinal root was cut. A microdialysis probe was inserted into the L7 dorsal horn region ipsilateral to the contracting triceps surae muscle. The probe was perfused with a buffer solution at 3 microliters/min. Substance P-like immunoreactivity (SP-LI) was measured, from the microdialysis samples, by radioimmunoassay. 2. A 5-9 min contraction of the triceps surae muscle was evoked by alternate electrical stimulation of the peripheral ends of the cut L7 and S1 ventral roots. Basal SP-LI release was 0.20 +/- 0.03 fmol/100 microliters and was increased to 0.54 +/- 0.05 fmol/100 microliters (mean +/- S.D.) by static muscle contraction. This increase was greatly attenuated after cutting the L7 and S1 dorsal roots (0.23 +/- 0.03 to 0.39 +/- 0.08 fmol/100 microliters) or completely abolished by muscle paralysis (0.27 +/- 0.03 to 0.31 +/- 0.01 fmol/100 microliters). Muscle contraction also increased mean arterial blood pressure (MAP) 29 +/- 20 mmHg and heart rate (HR) 11 +/- 5 beats/min (mean +/- S.D.). These cardiovascular changes to muscle contraction were abolished by sectioning the dorsal roots or when the ventral roots were electrically stimulated after the cats were paralysed. 3. These results demonstrate that static contraction of skeletal muscle increases the release of SP-LI in the dorsal horn of the spinal cord. Furthermore, these data support the hypothesis that SP plays a role in mediating the cardiovascular responses evoked during static exercise. PMID:7683719
NASA Astrophysics Data System (ADS)
Miranda, G.; Ferreira, P.; Buciumeanu, M.; Cabral, A.; Fredel, M.; Silva, F. S.; Henriques, B.
2017-08-01
The current trend to replace cobalt in diamond cutting tools (DCT) for stone cutting has motivated the study of alternative materials for this end. The present study characterizes several copper-nickel-based materials (Cu-Ni; Cu-Ni-10Sn, Cu-Ni-15Sn, Cu-Ni-Sn-2WC and Cu-Ni-Sn-10WC) for using as matrix material for diamond cutting tools for stone. Copper-nickel-based materials were produced by hot pressing, at a temperature of 850 °C during 15 min and under an applied pressure of 50 MPa. The mechanical properties were evaluated though the shear strength and hardness values. The microstructures and fracture surfaces were analyzed by SEM. The wear behavior of all specimens was assessed using a reciprocating ball-on-plate tribometer. The hot pressing produced compacts with good densification. Sn and WC promoted enhanced mechanical properties and wear performance to Cu-Ni alloys. Cu-Ni-10Sn and Cu-Ni-10Sn-2WC displayed the best compromise between mechanical and wear performance.
Cooking frozen and thawed roasts: beef, pork, and lamb cuts.
Fulton, C; Davis, C
1975-09-01
Cooking time, yield, and palatability of paired beef, pork, and lamb roasts cooked from the frozen and thawed states were compared. Cooking time for all roasts averaged from 3 to 22 min. per pound longer for meat cooked from the frozen state. The longer cooking time from the frozen state. The longer cooking time from the frozen state was greater for roasts with a large amount of bone and for cuts cooked by braising than for less bony roasts and cuts cooked by roasting. Except for thawed beef rump roasts, which had a higher yield of cooked lean meat, yield of cooked lean meat from the various cuts of beef, pork, and lamb was not affected by the state at the start of cooking. Collectively, all pork roasts had a higher yield of cooked lean meat when cooked from the frozen state. Juiciness and natural flavor of the roasts were not affected by the state at the start of cooking. Lamb leg and rib roasts were more tender when cooked from the thawed state.
Karpowicz, Jolanta; Gryz, Krzysztof; Leszko, Wieslaw; Zradziński, Patryk
2013-01-01
Use of electro surgery units (ESU) in surgeries is linked with electromagnetic field emission, which is assessed according to the requirements of occupational health and safety legislation. Surgeons' exposure characteristics was monitored during 11 surgeries (proctectomy, patency of artery, hepatectomy, cystectomy, tonsilectomy, laparoscopy) by real time of monopolar ESU activity recorder. Investigations of root-mean-square value of electric and magnetic field strength was also performed at various modes of ESU operations during cutting (output power, 55-150 W; frequency, 330-445 kHz) and coagulating (40-240 W, 335-770 kHz). Statistical parameters of distribution of ESU operation over any 6-min periods (according to international requirements regarding protection against adverse thermal effects of electromagnetic field) were assessed. Electric field strength, measured 10 cm from the cable supplying an active electrode was 147-675 V/m during cutting and 297-558 V/m during coagulating; magnetic field strength was less than 0.2 A/m in both modes. Monitoring of ESUs showed the following ranges of their operation during surgeries 5-66% of time over starting 3 min of surgery, 3-40% over starting 6 min, and the distribution of their use over any 6-min periods 0-12% (median) / 7-43% (maximum value). The real operation time of ESUs ing surgeries was significantly shorter than that declared by workers. The distance of at least 15 cm between cables, connecting electrodes with generator and workers meets the requirements of the Polish legislation on permissible exposure limits. The assessment of localized exposure of the hand needs a detailed analysis of the SAR ratio distribution and further studies are required.
3D segmentation of lung CT data with graph-cuts: analysis of parameter sensitivities
NASA Astrophysics Data System (ADS)
Cha, Jung won; Dunlap, Neal; Wang, Brian; Amini, Amir
2016-03-01
Lung boundary image segmentation is important for many tasks including for example in development of radiation treatment plans for subjects with thoracic malignancies. In this paper, we describe a method and parameter settings for accurate 3D lung boundary segmentation based on graph-cuts from X-ray CT data1. Even though previously several researchers have used graph-cuts for image segmentation, to date, no systematic studies have been performed regarding the range of parameter that give accurate results. The energy function in the graph-cuts algorithm requires 3 suitable parameter settings: K, a large constant for assigning seed points, c, the similarity coefficient for n-links, and λ, the terminal coefficient for t-links. We analyzed the parameter sensitivity with four lung data sets from subjects with lung cancer using error metrics. Large values of K created artifacts on segmented images, and relatively much larger value of c than the value of λ influenced the balance between the boundary term and the data term in the energy function, leading to unacceptable segmentation results. For a range of parameter settings, we performed 3D image segmentation, and in each case compared the results with the expert-delineated lung boundaries. We used simple 6-neighborhood systems for n-link in 3D. The 3D image segmentation took 10 minutes for a 512x512x118 ~ 512x512x190 lung CT image volume. Our results indicate that the graph-cuts algorithm was more sensitive to the K and λ parameter settings than to the C parameter and furthermore that amongst the range of parameters tested, K=5 and λ=0.5 yielded good results.
Villa, Gianluca; Neri, Mauro; De Rosa, Silvia; Samoni, Sara; Chelazzi, Cosimo; Romagnoli, Stefano; Lorenzin, Anna; de Cal, Massimo; Ronco, Claudio; De Gaudio, Angelo Raffaele
2018-06-08
Convective therapies with high cut-off membranes (HCO) are usually not recommended because of theoretical excessive albumin loss. The aim of this in vitro study is to demonstrate the noninferior safety of pre-dilution hemodiafiltration with HCO (HCO-CVVHDF) with isotonic citrate anticoagulation (18 mmol/L) with respect to heparin anticoagulated hemodialysis with HCO (HCO-CVVHD) in terms of albumin removal and citrate load. -Albumin removal was compared in vitro between 3 pre--dilution-HCO-CVVHDF with citrate anticoagulation and 3 -HCO-CVVHD with heparin anticoagulation during 30-min single-pass and 180-min recirculation phases. Considering concentrations and flows in the extracorporeal circuit, the transmembrane albumin removal was 2.06 (1.51; 2.09) g and 2.09 (1.9; 2.8) g respectively for HCO-CVVHDF and HCO-CVVHD, during the single-pass phase; 2.8 (2.67; 4.59) g and 2.54 (2.35; 4.67) g, respectively, for HCO-CVVHDF and HCO-CVVHD during the recirculation phase. Based on the citrate saturation coefficients, a citrate metabolic load of 8.86 mmol/h has been calculated for HCO-CVVHDF. HCO-CVVHDF performed with regional anticoagulation with 18 mmol/L citrate solution does not induce higher -albumin transmembrane removal compared to HCO-CVVHD. © 2018 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Hiremath, Vijaykumar; Badiger, Pradeep; Auradi, V.; Dundur, S. T.; Kori, S. A.
2016-02-01
Amongst advanced materials, metal matrix composites (MMC) are gaining importance as materials for structural applications in particular, particulate reinforced aluminium MMCs have received considerable attention due to their superior properties such as high strength to weight ratio, excellent low-temperature performance, high wear resistance, high thermal conductivity. The present study aims at studying and comparing the machinability aspects of B4Cp reinforced 6061Al alloy metal matrix composites reinforced with 37μm and 88μm particulates produced by stir casting method. The micro structural characterization of the prepared composites is done using Scanning Electron Microscopy equipped with EDX analysis (Hitachi Su-1500 model) to identify morphology and distribution of B4C particles in the 6061Al matrix. The specimens are turned on a conventional lathe machine using a Polly crystalline Diamond (PCD) tool to study the effect of particle size on the cutting forces and the surface roughness under varying machinability parameters viz., Cutting speed (29-45 m/min.), Feed rate (0.11-0.33 mm/rev.) and depth of cut (0.5-1mm). Results of micro structural characterization revealed fairly uniform distribution of B4C particles (in both cases i.e., 37μm and 88μm) in 6061Al matrix. The surface roughness of the composite is influenced by cutting speed. The feed rate and depth of cut have a negative influence on surface roughness. The cutting forces decreased with increase in cutting speed whereas cutting forces increased with increase in feed and depth of cut. Higher cutting forces are noticed while machining Al6061 base alloy compared to reinforced composites. Surface finish is high during turning of the 6061Al base alloy and surface roughness is high with 88μm size particle reinforced composites. As the particle size increases Surface roughness also increases.
Durmuş, Gündüz; Belen, Erdal; Can, Mehmet Mustafa
The neutrophil to lymphocyte ratio (NLR), has been proposed as potential indicator of cardiovascular events. Our aim was to determine the relationship between NLR and development of myocardial injury after non-cardiac surgery (MINS). This observational cohort study included 255 consecutive noncardiac surgery patients aged ≥45 years. Electrocardiography recordings and high sensitivity cardiac troponin T (hscTnT) levels of the patients were obtained for a period of 3 days postoperatively. MINS was detected in 30 (11.8%) patients using the cut-off level of ≥14 ng/L for hscTnT. In the MINS group NLR (3.79 ± 0.7 vs. 2.69 ± 0.6, p < 0.000) values were higher than non-NLR group. The NLR to be independently associated with the development of MINS (OR: 11.690; CI: 4.619-29.585, p < 0.000). NLR seems to be a simple, easy and cheap tool to predict the development of MINS in patient undergoing non-cardiac surgery. Copyright © 2018 Elsevier Inc. All rights reserved.
Urine Biomarkers and Perioperative Acute Kidney Injury: The Impact of Preoperative Estimated GFR
Koyner, Jay L.; Coca, Steven G.; Thiessen-Philbrook, Heather; Patel, Uptal D.; Shlipak, Michael; Garg, Amit X.; Parikh, Chirag R.
2015-01-01
Background The interaction between baseline kidney function and the performance of biomarkers of acute kidney injury (AKI) on the development of AKI is unclear. Study Design Post-hoc analysis of prospective cohort study. Setting & Participants The 1,219 TRIBE-AKI Consortium adult cardiac surgery cohort participants. Predictor Unadjusted post-operative urinary biomarkers of AKI measured within 6 hours of surgery. Outcome AKI was defined as greater than or equal to AKI Network stage 1 (any AKI) as well as a doubling of serum creatinine from the pre-operative value or the need for emergent dialysis (severe AKI). Measurements Stratified analyses by a pre-operative eGFR ≤ 60 ml/min/1.73 m2 vs. > 60 ml/min/1.73 m2. Results 180 (42%) patients with a pre-operative eGFR ≤ 60 ml/min/1.73m2 developed clinical AKI compared to 246 (31%) in those with an eGFR >60 ml/min//1.73m2 (p<0.001). For log2-transformed biomarker concentrations there was a significant interaction between any AKI and baseline eGFR for interleukin 18 (IL-18; p=0.007) and borderline significance for liver-type fatty acid binding protein (p=0.06). For all biomarkers, the adjusted relative risk (RR) point estimates for the risk of any AKI were higher in those with elevated baseline eGFRs compared to those with an eGFR ≤ 60 ml/min/1.73m2. However the difference in magnitude of these risks were quite low (adjusted RRs were 1.04 [95% CI, 0.99–1.09] and 1.11 [95% CI, 1.07–1.15] for those with a pre-operative eGFR ≤ 60 ml/min/1.73 m2 and those with higher eGFRs, respectively). Although no biomarker displayed an interaction for baseline eGFR and severe AKI, log2-transformed IL-18 and kidney injury molecule 1 (KIM-1) had significant adjusted RRs for severe AKI in those with and without baseline eGFR ≤ 60 ml/min/1.73 m2. Limitations Limited numbers of patients with severe AKI and emergent dialysis. Conclusions The association between early post-operative AKI urinary biomarkers and AKI is modified by preoperative eGFR. The degree of this modification and its impact on the biomarker-AKI association is small across biomarkers. Our findings suggest that distinct biomarker cut-offs for those with and without a pre-operative eGFR ≤ 60 ml/min/1.73 m2 is not necessary. PMID:26386737
Jerry F. Franklin
1963-01-01
Clear cutting is the standard harvesting system in old-growth Douglas-fir (Pseudotsuga menziesii) forests in the Pacific Northwest. Usually these clear cuts are in "staggered settings" of 15 to 80 acres with the surrounding stand left uncut to provide seed and serve as a firebreak. However, satisfactory natural regeneration of Douglas-fir...
2014-01-24
2013 was a big year for Ames Research Center's space exploration programs, including several new launches, and continuing a long history of cutting-edge innovations. Projects listed include: LADEE, IRIS, Kepler, PhoneSat, TechEdSat, NLAS, K10 Rover, Seedling Growth-1, Cell Biology Tech Demonstration, ADEPT, Spaceloft 7 and 8, CheMin, MSL, MRO, Bion-M1, Pioneer 11.
USDA-ARS?s Scientific Manuscript database
Whole cantaloupes either not inoculated or inoculated with Salmonella Poona were submerged in water, 100 ppm chlorine, acidified calcium sulfate (ACS: 1.2% Safe2O ACS50), 1000 ppm acidified sodium chlorite (Sanova), 80 ppm peroxyacetic acid (Tsunami), and combination of ACS and Tsunami for 10 min. ...
Liao, C-H; Fett, W F
2005-01-01
To investigate the resuscitation of acid-injured Salmonella enterica in selected enrichment broths, in apple juice and on cut surfaces of apple and cucumber slices. Following exposure to 2.4% acetic acid for 7 min, S. enterica (serovars Mbandaka, Chester and Newport) cells were used to inoculate enrichment broths, phosphate-buffered saline (PBS), apple juice and fruit slices. Injured Salmonella cells resuscitated and regained the ability to form colonies on selective agar (Xylose-Lysine-Tergitol 4) if they were incubated in lactose broth (LB), universal pre-enrichment broth (UPB) or buffered peptone water (BPW), but not in tetrathionate broth, PBS or apple juice. The resuscitation occurred at a significantly (P > 0.05) faster rate in UPB than in LB or BPW. The resuscitation also occurred on the surfaces of fresh-cut cucumber at 20 degrees C, but not at 4 degrees C. Acid-injured Salmonella cells resuscitated in nonselective enrichment broths at different rates, but not in selective enrichment broth, apple juice, PBS or on fresh-cut apple. Pre-enrichment of food samples in UPB prior to selective enrichment is recommended. Injured Salmonella cells have the ability to resuscitate on fresh-cut surfaces of cucumber when stored at abusive temperatures.
NASA Astrophysics Data System (ADS)
Octarina, Sisca; Radiana, Mutia; Bangun, Putra B. J.
2018-01-01
Two dimensional cutting stock problem (CSP) is a problem in determining the cutting pattern from a set of stock with standard length and width to fulfill the demand of items. Cutting patterns were determined in order to minimize the usage of stock. This research implemented pattern generation algorithm to formulate Gilmore and Gomory model of two dimensional CSP. The constraints of Gilmore and Gomory model was performed to assure the strips which cut in the first stage will be used in the second stage. Branch and Cut method was used to obtain the optimal solution. Based on the results, it found many patterns combination, if the optimal cutting patterns which correspond to the first stage were combined with the second stage.
Effect of agitation time on nutrient distribution in full-scale CSTR biogas digesters.
Kress, Philipp; Nägele, Hans-Joachim; Oechsner, Hans; Ruile, Stephan
2018-01-01
The aim of this work was to study the impact of reduced mixing time in a full-scale CSTR biogas reactor from 10 to 5 and to 2min in half an hour on the distribution of DM, acetic acid and FOS/TAC as a measure to cut electricity consumption. The parameters in the digestate were unevenly distributed with the highest concentration measured at the point of feeding. By reducing mixing time, the FOS/TAC value increases by 16.6%. A reduced mixing time of 2min lead to an accumulation of 15% biogas in the digestate. Copyright © 2017 Elsevier Ltd. All rights reserved.
Racking Response of Reinforced Concrete Cut and Cover Tunnel
DOT National Transportation Integrated Search
2016-01-01
Currently, the knowledge base and quantitative data sets concerning cut and cover tunnel seismic response are scarce. In this report, a large-scale experimental program is conducted to assess: i) stiffness, capacity, and potential seismically-induced...
Karnowski, Thomas P [Knoxville, TN; Tobin, Jr., Kenneth W.; Muthusamy Govindasamy, Vijaya Priya [Knoxville, TN; Chaum, Edward [Memphis, TN
2012-07-10
A method for assigning a confidence metric for automated determination of optic disc location that includes analyzing a retinal image and determining at least two sets of coordinates locating an optic disc in the retinal image. The sets of coordinates can be determined using first and second image analysis techniques that are different from one another. An accuracy parameter can be calculated and compared to a primary risk cut-off value. A high confidence level can be assigned to the retinal image if the accuracy parameter is less than the primary risk cut-off value and a low confidence level can be assigned to the retinal image if the accuracy parameter is greater than the primary risk cut-off value. The primary risk cut-off value being selected to represent an acceptable risk of misdiagnosis of a disease having retinal manifestations by the automated technique.
A new method for digital video documentation in surgical procedures and minimally invasive surgery.
Wurnig, P N; Hollaus, P H; Wurnig, C H; Wolf, R K; Ohtsuka, T; Pridun, N S
2003-02-01
Documentation of surgical procedures is limited to the accuracy of description, which depends on the vocabulary and the descriptive prowess of the surgeon. Even analog video recording could not solve the problem of documentation satisfactorily due to the abundance of recorded material. By capturing the video digitally, most problems are solved in the circumstances described in this article. We developed a cheap and useful digital video capturing system that consists of conventional computer components. Video images and clips can be captured intraoperatively and are immediately available. The system is a commercial personal computer specially configured for digital video capturing and is connected by wire to the video tower. Filming was done with a conventional endoscopic video camera. A total of 65 open and endoscopic procedures were documented in an orthopedic and a thoracic surgery unit. The median number of clips per surgical procedure was 6 (range, 1-17), and the median storage volume was 49 MB (range, 3-360 MB) in compressed form. The median duration of a video clip was 4 min 25 s (range, 45 s to 21 min). Median time for editing a video clip was 12 min for an advanced user (including cutting, title for the movie, and compression). The quality of the clips renders them suitable for presentations. This digital video documentation system allows easy capturing of intraoperative video sequences in high quality. All possibilities of documentation can be performed. With the use of an endoscopic video camera, no compromises with respect to sterility and surgical elbowroom are necessary. The cost is much lower than commercially available systems, and setting changes can be performed easily without trained specialists.
Mohan, Alladi; Reddy, S. Aparna; Sachan, Alok; Sarma, K.V.S.; Kumar, D. Prabath; Panchagnula, Mahesh V.; Rao, P.V.L.N. Srinivasa; Kumar, B. Siddhartha; Krishnaprasanthi, P.
2016-01-01
Background & Objectives: Glycosylated haemoglobin (HbA1c) has been in use for more than a decade, as a diagnostic test for type 2 diabetes. Validity of HbA1c needs to be established in the ethnic population in which it is intended to be used. The objective of this study was to derive and validate a HbA1c cut-off value for the diagnosis of type 2 diabetes in the ethnic population of Rayalaseema area of south India. Methods: In this cross-sectional study, consecutive patients suspected to have type 2 diabetes underwent fasting plasma glucose (FPG) and 2 h post-load plasma glucose (2 h-PG) measurements after a 75 g glucose load and HbA1c estimation. They were classified as having diabetes as per the American Diabetes Association criteria [(FPG ≥7 mmol/l (≥126 mg/dl) and/or 2 h-PG ≥11.1 mmol/l (≥200 mg/dl)]. In the training data set (n = 342), optimum cut-off value of HbA1c for defining type 2 diabetes was derived by receiver-operator characteristic (ROC) curve method using oral glucose tolerance test results as gold standard. This cut-off was validated in a validation data set (n = 341). Results: On applying HbA1c cut-off value of >6.3 per cent (45 mmol/mol) to the training data set, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for diagnosing type 2 diabetes were calculated to be 90.6, 85.2, 80.8 and 93.0 per cent, respectively. When the same cut-off value was applied to the validation data set, sensitivity, specificity, PPV and NPV were 88.8, 81.9, 74.0 and 92.7 per cent, respectively, although the latter were consistently smaller than the proportions for the training data set, the differences being not significant. Interpretation & conclusions: HbA1c >6.3 per cent (45 mmol/mol) appears to be the optimal cut-off value for the diagnosis of type 2 diabetes applicable to the ethnic population of Rayalaseema area of Andhra Pradesh state in south India. PMID:27934801
Holtmeier, Julia; Leuschner, Maria; Schneider, Arne; Leuschner, Ulrich; Caspary, Wolfgang F; Braden, Barbara
2006-11-01
The 13C-methacetin breath test quantitatively evaluates cytochrome P450-dependent liver function. The 13C-galactose breath test non-invasively measures the galactose oxidation capacity of the liver. The aim of this study was to find out whether these breath tests are sensitive parameters also in non-cirrhotic patients with primary biliary cirrhosis. Nineteen patients with early-stage primary biliary cirrhosis (no cirrhotic alterations in the liver biopsy, Ludwig stage I-III) and 20 healthy controls underwent the 13C-methacetin and 13C-galactose breath tests. Patients with primary biliary cirrhosis metabolized less 13C-methacetin than controls (cumulative recovery within 30 min 7.5+/-2.4% versus 14.0+/-2.6%; p < 0.001). When a cut-off > 9.8% was used for the cumulative recovery after 30 min, the methacetin breath test reached 84.2% sensitivity and 95.0 specificity. In the 13C-galactose breath test, the percentage recovery at 60 min in patients was 3.1+/-1.3%/h, and 6.3+/-1.1%/h in controls (p < 0.001). Using a cut-off > 4.7%/h, the galactose breath test reached 89.5% sensitivity and 95.0 specificity. In non-cirrhotic, early-stage, primary biliary cirrhosis the 13C-methacetin breath test and the 13C-galactose breath test reliably indicate decreased liver function. The 13C-galactose breath test can also predict the histological score.
Greater vertical spot spacing to improve femtosecond laser capsulotomy quality.
Schultz, Tim; Joachim, Stephanie C; Noristani, Rozina; Scott, Wendell; Dick, H Burkhard
2017-03-01
To evaluate the effect of adapted capsulotomy laser settings on the cutting quality in femtosecond laser-assisted cataract surgery. Ruhr-University Eye Clinic, Bochum, Germany. Prospective randomized case series. Eyes were treated with 1 of 2 laser settings. In Group 1, the regular standard settings were used (incisional depth 600 μm, pulse energy 4 μJ, horizontal spot spacing 5 μm, vertical spot spacing 10 μm, treatment time 1.2 seconds). In Group 2, vertical spot spacing was increased to 15 μm and the treatment time was 1.0 seconds. Light microscopy was used to evaluate the cut quality of the capsule edge. The size and number of tags (misplaced laser spots, which form a second cut of the capsule with high tear risk) were evaluated in a blinded manner. Groups were compared using the Mann-Whitney U test. The study comprised 100 eyes (50 eyes in each group). Cataract surgery was successfully completed in all eyes, and no anterior capsule tear occurred during the treatment. Histologically, significant fewer tags were observed with the new capsulotomy laser setting. The mean score for the number and size of free tags was significantly lower in this group than with the standard settings (P < .001). The new laser settings improved cut quality and reduced the number of tags. The modification has the potential to reduce the risk for radial capsule tears in femtosecond laser-assisted cataract surgery. With the new settings, no tags and no capsule tears were observed under the operating microscope in any eye. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Orthogonal cutting of laser beam melted parts
NASA Astrophysics Data System (ADS)
Götze, Elisa; Zanger, Frederik; Schulze, Volker
2018-05-01
The finishing process of parts manufactured by laser beam melting is of high concern due to the lack of surface accuracy. Therefore, the focus of this work lies on the influence of the build-up direction of the parts and their effect on the finishing process. The orthogonal cutting reveals findings in the fields of chip formation, involved forces and temperatures appearing during machining. In the investigations, the cutting depth was varied between 0.05 and 0.15 mm representing a finishing process and the cutting velocity ranges from 30 to 200 m/min depending on the material. The experiments contain the materials stainless steel (AISI 316L), titanium (Ti6Al4V) and nickel-base alloy (IN718). The two materials named latter are of high interest in the aerospace sector and at the same time titanium is used in the medical field due to its biocompatibility. For the materials IN718 and Ti6Al4V a negative rake angle of -7.5° and for stainless steel a rake angle of 12.5° are chosen for the cutting experiments. The results provide the base for processing strategies. Therefore, the specimens were solely laser beam melted without post-processing like heat treatment. The evaluation of the experiments shows that an increase in cutting speed has different effects depending on the material. For stainless steel the measured forces regarding the machining direction to the layers approach the same values. In contrast, the influence of the layers regarding the forces appearing during orthogonal cutting of the materials IN718 and Ti6Al4V differ for lower cutting speeds.
Cut set-based risk and reliability analysis for arbitrarily interconnected networks
Wyss, Gregory D.
2000-01-01
Method for computing all-terminal reliability for arbitrarily interconnected networks such as the United States public switched telephone network. The method includes an efficient search algorithm to generate minimal cut sets for nonhierarchical networks directly from the network connectivity diagram. Efficiency of the search algorithm stems in part from its basis on only link failures. The method also includes a novel quantification scheme that likewise reduces computational effort associated with assessing network reliability based on traditional risk importance measures. Vast reductions in computational effort are realized since combinatorial expansion and subsequent Boolean reduction steps are eliminated through analysis of network segmentations using a technique of assuming node failures to occur on only one side of a break in the network, and repeating the technique for all minimal cut sets generated with the search algorithm. The method functions equally well for planar and non-planar networks.
NASA Astrophysics Data System (ADS)
Stock, Karl; Diebolder, Rolf; Hausladen, Florian; Hibst, Raimund
2014-03-01
It is well known that flashlamp pumped Er:YAG lasers allow efficient bone ablation due to strong absorption at 3μm by water. Preliminary experiments revealed also a newly developed diode pumped Er:YAG laser system (Pantec Engineering AG) to be an efficient tool for use for bone surgery. The aim of the present in vitro study is the investigation of a new power increased version of the laser system with higher pulse energy and optimization of the treatment set-up to get high cutting quality, efficiency, and ablation depth. Optical simulations were performed to achieve various focus diameters and homogeneous beam profile. An appropriate experimental set-up with two different focusing units, a computer controlled linear stage with sample holder, and a shutter unit was realized. By this we are able to move the sample (slices of pig bone) with a defined velocity during the irradiation. Cutting was performed under appropriate water spray by moving the sample back and forth. After each path the ablation depth was measured and the focal plane was tracked to the actual bottom of the groove. Finally, the cuts were analyzed by light microcopy regarding the ablation quality and geometry, and thermal effects. In summary, the results show that with carefully adapted irradiation parameters narrow and deep cuts (ablation depth > 6mm, aspect ratio approx. 20) are possible without carbonization. In conclusion, these in vitro investigations demonstrate that high efficient bone cutting is possible with the diode pumped Er:YAG laser system using appropriate treatment set-up and parameters.
High-precision micro/nano-scale machining system
Kapoor, Shiv G.; Bourne, Keith Allen; DeVor, Richard E.
2014-08-19
A high precision micro/nanoscale machining system. A multi-axis movement machine provides relative movement along multiple axes between a workpiece and a tool holder. A cutting tool is disposed on a flexible cantilever held by the tool holder, the tool holder being movable to provide at least two of the axes to set the angle and distance of the cutting tool relative to the workpiece. A feedback control system uses measurement of deflection of the cantilever during cutting to maintain a desired cantilever deflection and hence a desired load on the cutting tool.
Next-to-leading order γ γ + 2 - jet production at the LHC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bern, Z.; Dixon, L. J.; Febres Cordero, F.
We present next-to-leading-order QCD predictions for cross sections and for a comprehensive set of distributions in γγ+2-jet production at the Large Hadron Collider. We consider the contributions from loop amplitudes for two photons and four gluons, but we neglect top quarks. We use BlackHat together with SHERPA to carry out the computation. We use a Frixione cone isolation for the photons. We study standard sets of cuts on the jets and the photons and also sets of cuts appropriate for studying backgrounds to Higgs-boson production via vector-boson fusion.
Khalid, Rizvan; Knowles, Toby G; Wotton, Steve B
2015-12-01
Blood lost at exsanguination during the Halal slaughter of lambs was compared between the slaughter methods of Traditional Religious Slaughter without stunning (TRS), Electric Head-Only Stunning (EHOS) and Post-Cut Electric Head-Only Stunning (PCEHOS). Two protocols were examined, Experimental (80 lambs) and Commercial (360 lambs), assessing varying periods of animal orientation during the 4 min bleeding process (upright orientation before vertical hanging). Live-weight, blood weight (Experimental only), carcass weights and by-product weights were recorded. The Experimental protocol highlighted an increase in blood loss at 60s in EHOS and PCEHOS compared to TRS (P<0.001) but by 90 s there was no significant difference. A post-slaughter change in animal orientation from an upright to a vertical hanging position aided the amount of blood loss. The bleeding of lambs is largely completed by 2 min. There were no significant differences (P>0.05) in final blood loss between treatments. This research was undertaken to inform discussion on the merits of different slaughter methods compatible with Halal requirements. Copyright © 2015. Published by Elsevier Ltd.
Western Wind Data Set | Grid Modernization | NREL
replicates the stochastic nature of wind power plant output. NREL modeled hysteresis around wind turbine cut where wind speeds are often near wind turbine cut-out (~25 m/s), SCORE output does not replicate the Vestas V90). The hysteresis-corrected SCORE is an attempt to put the wind turbine hysteresis at cut-out
3. Oblique view of building in setting; view to northwest, ...
3. Oblique view of building in setting; view to northwest, 65mm lens. Railroad cut in foreground was made in 1928 when Southern Pacific Railroad realigned its main line in connection with the construction of its Martinez-Benicia Bridge. It was this cut which led to continual settlement of the southeast corner of the building, resulting in its structural failure. - Benicia Arsenal, Powder Magazine No. 5, Junction of Interstate Highways 680 & 780, Benicia, Solano County, CA
Selma, María V; Allende, Ana; López-Gálvez, Francisco; Conesa, María A; Gil, María I
2008-09-01
The purpose of this research was to investigate the disinfection efficacy of ozone (O(3)) and UV-C illumination (UV), and their combination (O(3)-UV) for reducing microbial flora of fresh-cut onion, escarole, carrot, and spinach wash waters collected from the industry. Furthermore, the influence of water physicochemical parameters on the decontamination efficacy and the effect of these technologies on physicochemical quality of wash water were analyzed. O(3), UV, and O(3)-UV were effective disinfection treatments on vegetable wash water, with a maximum microbial reduction of 6.6 log CFU mL(-1) after 60 min treatment with O(3)-UV. However, maximum total microbial reductions achieved by UV and O(3) treatments after 60 min were 4.0 and 5.9 log CFU mL(-1), lower than by O(3)-UV treatment. Furthermore, turbidity of wash water was reduced significantly by O(3) and O(3)-UV treatments, while UV treatment did not affect the physicochemical quality of the water. Conclusions derived from this study illustrate that O(3) and O(3)-UV are alternatives to other sanitizers used in the fresh-cut washing processes. The use of these technologies would allow less frequent changing of spent water and the use of much lower sanitizer doses. Nevertheless, in specific applications such as carrot wash water, where levels of undesirable microbial and chemical constituents are lower than other vegetable wash water, UV treatment could be an appropriate treatment considering cost-effectiveness criteria.
Post-dive ultrasound detection of gas in the liver of rats and scuba divers.
L'abbate, Antonio; Marabotti, Claudio; Kusmic, Claudia; Pagliazzo, Antonino; Navari, Alessandro; Positano, Vincenzo; Palermo, Mario; Benassi, Antonio; Bedini, Remo
2011-09-01
In a previous study, we obtained histologic documentation of liver gas embolism in the rat model of rapid decompression. The aim of the study was to assess in the same model occurrence and time course of liver embolism using 2-D ultrasound imaging, and to explore by this means putative liver gas embolism in recreational scuba divers. Following 42 min compression at 7 ATA breathing air and 12 min decompression, eight surviving female rats were anesthetized and the liver imaged by ultrasound at 20 min intervals up to 120 min. A significant enhancement of echo signal was recorded from 60 to 120 min as compared to earlier post-decompression times. Enzymatic markers of liver damage (AST, ALT, and GGT) increased significantly at 24 h upon decompression. Twelve healthy experienced divers were studied basally and at 15-min intervals up to 60 min following a 30-min scuba dive at 30 msw depth. At 30 min upon surfacing echo images showed significant signal enhancement that progressed and reached plateau at 45 and 60 min. Total bilirubin at 24 h increased significantly (p = 0.02) with respect to basal values although within the reference range. In conclusion, 2-D ultrasound liver imaging allowed detection of gas embolism in the rat and defined the time course of gas accumulation. Its application to scuba divers revealed liver gas accumulation in all subjects in the absence of clear-cut evidence of liver damage or of any symptom. The clinical significance of our findings remains to be investigated.
A New On-Line Detecting Apparatus of the Residual Chlorine in Disinfectant for Fresh-Cut Vegetables
NASA Astrophysics Data System (ADS)
Hu, Chao; Su, Shu-Qiang; Li, Bao-Guo; Liu, Meng-Fang
With the fast development of modern food and beverage industry, fresh-cut vegetables have wider application than before. During the process of sterilization in fresh-cut vegetables, the concentration of chloric disinfectant is usually so high that the common sensor can't be used directly on the product line. In order to solve this problem, we have invented a new detecting apparatus which could detect high concentration of chloric disinfectant directly. In this paper, the working principle, main monitor indicators, application and technical creations of the on-line apparatus have been discussed, and we also carried on the experimental analysis for its performance. The actual demands in factory could be met when the detecting flux is 2L/min, the dilution ratio is 15 and input amount of the disinfectant is 200ml per time, the max of the detecting deviation achieves ±4.8ppm(mg/L). The main detecting range of residual chlorine is 0~300ppm.
Docimo, T; Francese, G; De Palma, M; Mennella, D; Toppino, L; Lo Scalzo, R; Mennella, G; Tucci, M
2016-06-08
Color, taste, flavor, nutritional value, and shelf life are important factors determining quality and healthiness of food and vegetables. These factors are strongly affected by browning processes, occurring after fruit or vegetable cutting. Characterization of ten eggplant genotypes for chlorogenic acid (CGA) content, total phenols (TP), polyphenoloxidase (PPO) activity, and browning tendency corroborated a lack of significant correlations between biochemical factors and fruit flesh browning. Further in-depth molecular and biochemical analyses of two divergent eggplant genetic lines, AM199 (high browning) and AM086 (low browning), within 30 min from cutting, highlighted differences in the physiological mechanisms underlying the browning process. qRT-PCR analysis revealed distinct activation mechanisms of CGA biosynthetic and PPO genes in the two genetic lines. Metabolic data on CGA, sugars, and ascorbic acid contents confirmed that their different browning tendency matched with different metabolic responses to cutting. Our findings suggest that the complex mechanism of flesh browning in the two eggplant genetic lines might be mediated by multiple specific factors.
Ultrasound-Guided Percutaneous Tenotomy of Biceps Tendon: Technical Feasibility on Cadavers.
Sconfienza, Luca Maria; Mauri, Giovanni; Messina, Carmelo; Aliprandi, Alberto; Secchi, Francesco; Sardanelli, Francesco; Randelli, Pietro Simone
2016-10-01
We tested the technical feasibility of ultrasound-guided percutaneous tenotomy of the long head of the biceps tendon (LHBT) in cadavers. Both shoulders of two fresh cadavers were scanned anteriorly to evaluate the extra-articular portion of the LHBT. Under ultrasound monitoring, a scalpel was advanced obliquely up to touch the superficial medial side of the LHBT, cutting it until the tendon was not visible anymore. Ultrasound evaluation was repeated after the procedure, and anatomic dissection was performed. The procedure was 100% feasible: four cuts were made to completely sever the tendon; the duration was less than 1 min. Skin incision measured 5 mm in two cases and 6 mm in two cases. Anatomic dissection confirmed complete tendon cut in all cases with proximal and distal tendon stumps very close to each other. Ultrasound-guided percutaneous LHBT tenotomy was 100% technically feasible in cadavers with a quick procedure and minimal cutaneous incision. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Nitric oxide inhibition of alcohol dehydrogenase in fresh-cut apples ( Malus domestica Borkh).
Amissah, Joris Gerald Niilante; Hotchkiss, Joseph H; Watkins, Chris B
2013-11-20
The effects of nitric oxide (NO) and nitrite treatment on alcohol dehydrogenase activity and the shelf life of apple tissue were investigated. Fresh-cut apple slices were stored for 2 days at 6 °C in 0.25-1% NO (v/v, balance N2) or 100% N2 atmospheres. Slices were also treated with 1% NO or 2 mM sodium nitrite (NaNO2) for 20 min, stored for 6 weeks in 100% N2 at 6 °C, and analyzed for acetaldehyde, ethanol, and ethyl acetate accumulation, firmness, and color. Compared with N2 or deionized water controls, treatment with 1% NO or 2 mM NaNO2 inhibited ethanol accumulation, whereas that of acetaldehyde increased. Ethyl acetate accumulation was inhibited only by NO. Slice firmness was not affected by NO or NaNO2 treatment, but slices were darker than the untreated controls. NO and nitrite may extend the shelf life of fresh-cut produce with low concentrations of phenolic compounds.
Calibration and field application of a Sierra Model 235 cascade impactor.
Knuth, R H
1984-06-01
A Sierra Model 235 slotted impactor was used to measure the particle size distribution of ore dust in uranium concentrating mills. The impactor was calibrated at a flow rate of 0.21 m3/min, using solid monodisperse particles of methylene blue and an impaction surface of Whatman #41 filter paper soaked in mineral oil. The reduction from the impactor's design flow rate of 1.13 m3/min (40 cfm) to 0.21 m3/min (7.5 cfm), a necessary adjustment because of the anticipated large particles sizes of ore dust, increased the stage cut-off diameters by an average factor of 2.3. Evaluation of field test results revealed that the underestimation of mass median diameters, often caused by the rebound and reentrainment of solid particles from dry impaction surfaces, was virtually eliminated by using the oiled Whatman #41 impaction surface.
A decorated raven bone from the Zaskalnaya VI (Kolosovskaya) Neanderthal site, Crimea
Evans, Sarah; Stepanchuk, Vadim; Tsvelykh, Alexander; d’Errico, Francesco
2017-01-01
We analyze a radius bone fragment of a raven (Corvus corax) from Zaskalnaya VI rock shelter, Crimea. The object bears seven notches and comes from an archaeological level attributed to a Micoquian industry dated to between 38 and 43 cal kyr BP. Our study aims to examine the degree of regularity and intentionality of this set of notches through their technological and morphometric analysis, complemented by comparative experimental work. Microscopic analysis of the notches indicate that they were produced by the to-and-fro movement of a lithic cutting edge and that two notches were added to fill in the gap left between previously cut notches, probably to increase the visual consistency of the pattern. Multivariate analysis of morphometric data recorded on the archaeological notches and sets of notches cut by nine modern experimenters on radii of domestic turkeys shows that the variations recorded on the Zaskalnaya set are comparable to experimental sets made with the aim of producing similar, parallel, equidistant notches. Identification of the Weber Fraction, the constant that accounts for error in human perception, for equidistant notches cut on bone rods and its application to the Zaskalnaya set of notches and thirty-six sets of notches incised on seventeen Upper Palaeolithic bone objects from seven sites indicate that the Zaskalnaya set falls within the range of variation of regularly spaced experimental and Upper Palaeolithic sets of notches. This suggests that even if the production of the notches may have had a utilitarian reason the notches were made with the goal of producing a visually consistent pattern. This object represents the first instance of a bird bone from a Neanderthal site bearing modifications that cannot be explained as the result of butchery activities and for which a symbolic argument can be built on direct rather than circumstantial evidence. PMID:28355292
Inferring microbial interaction networks from metagenomic data using SgLV-EKF algorithm.
Alshawaqfeh, Mustafa; Serpedin, Erchin; Younes, Ahmad Bani
2017-03-27
Inferring the microbial interaction networks (MINs) and modeling their dynamics are critical in understanding the mechanisms of the bacterial ecosystem and designing antibiotic and/or probiotic therapies. Recently, several approaches were proposed to infer MINs using the generalized Lotka-Volterra (gLV) model. Main drawbacks of these models include the fact that these models only consider the measurement noise without taking into consideration the uncertainties in the underlying dynamics. Furthermore, inferring the MIN is characterized by the limited number of observations and nonlinearity in the regulatory mechanisms. Therefore, novel estimation techniques are needed to address these challenges. This work proposes SgLV-EKF: a stochastic gLV model that adopts the extended Kalman filter (EKF) algorithm to model the MIN dynamics. In particular, SgLV-EKF employs a stochastic modeling of the MIN by adding a noise term to the dynamical model to compensate for modeling uncertainties. This stochastic modeling is more realistic than the conventional gLV model which assumes that the MIN dynamics are perfectly governed by the gLV equations. After specifying the stochastic model structure, we propose the EKF to estimate the MIN. SgLV-EKF was compared with two similarity-based algorithms, one algorithm from the integral-based family and two regression-based algorithms, in terms of the achieved performance on two synthetic data-sets and two real data-sets. The first data-set models the randomness in measurement data, whereas, the second data-set incorporates uncertainties in the underlying dynamics. The real data-sets are provided by a recent study pertaining to an antibiotic-mediated Clostridium difficile infection. The experimental results demonstrate that SgLV-EKF outperforms the alternative methods in terms of robustness to measurement noise, modeling errors, and tracking the dynamics of the MIN. Performance analysis demonstrates that the proposed SgLV-EKF algorithm represents a powerful and reliable tool to infer MINs and track their dynamics.
Tibana, Ramires A; Vieira, Denis C L; Tajra, Vitor; Bottaro, Martim; de Salles, Belmiro F; Willardson, Jeffrey M; Prestes, Jonato
2013-12-01
This study compared two different rest intervals (RI) between sets of resistance exercise. Ten resistance-trained men (M age = 24.3, SD = 3.5 yr.; M weigh t= 80.0 kg, SD = 15.3; M height = 1.75 m, SD = 0.04) performed five sets of Smith machine bench presses at 60% of one repetition maximum, either with 1.5 min. or 3 min. RI between sets. Their repetition performance, total training volume, velocity, fatigue, rating of perceived exertion, and muscular power were measured. All of these measures indicated that performance was significantly better and fatigue was significantly lower in the 3 min. RI as compared with the 1.5 min. RI, except the rating of perceived exertion which did not show a significant difference. A longer RI between sets promotes superior performance for the bench press.
Calcium Sulfates at Gale Crater and Limitations on Gypsum Stability
NASA Technical Reports Server (NTRS)
Vantiman, D. T.; Martinez, G. M.; Rampe, E. B.; Bristow, T. F.; Blake, D. F.; Yen, A. H.; Ming, D. W.; Rapin, W.; Meslin, P. -Y.; Morookian, J. M.;
2017-01-01
The Mars Science Laboratory rover has been exploring sedimentary rocks of the Bradbury group and overlying Murray formation, as well as the unconformably overlying Stimson formation. Early in exploration, and continuing to present, there have been observations of many Ca-sulfate veins that cut all three stratigraphic units. The CheMin XRD instrument on Curiosity provides complete mineralogy for drilled or scooped samples, with explicit identification of gypsum, bassanite, and anhydrite (crystal structure of so-called "soluble anhydrite," or gamma-CaSO4, is so similar to bassanite that it can't be distinguished at CheMin 2-theta resolution; here we refer to these similar dehydrated forms simply as bassanite).
COMCAN: a computer program for common cause analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burdick, G.R.; Marshall, N.H.; Wilson, J.R.
1976-05-01
The computer program, COMCAN, searches the fault tree minimal cut sets for shared susceptibility to various secondary events (common causes) and common links between components. In the case of common causes, a location check may also be performed by COMCAN to determine whether barriers to the common cause exist between components. The program can locate common manufacturers of components having events in the same minimal cut set. A relative ranking scheme for secondary event susceptibility is included in the program.
One cutting plane algorithm using auxiliary functions
NASA Astrophysics Data System (ADS)
Zabotin, I. Ya; Kazaeva, K. E.
2016-11-01
We propose an algorithm for solving a convex programming problem from the class of cutting methods. The algorithm is characterized by the construction of approximations using some auxiliary functions, instead of the objective function. Each auxiliary function bases on the exterior penalty function. In proposed algorithm the admissible set and the epigraph of each auxiliary function are embedded into polyhedral sets. In connection with the above, the iteration points are found by solving linear programming problems. We discuss the implementation of the algorithm and prove its convergence.
Liu, Pou; Kantola, Kalle; Fukuda, Toshio; Arai, Fumihito
2009-05-01
We report that a series of in situ nanofabrication techniques of nanostructures, including cutting, bending and soldering of carbon nanotubes (CNTs), inside a field emission scanning electron microscope (FE-SEM) used for nanoassembly of nanostructures. The CNTs can be cut with electron beam assisted with oxygen gas. The cutting was developed for the bending of CNT, if some conditions of the cutting technique are changed. These include the increase of the acceleration voltage and/or setting the oxygen gas nozzle farther from the sample, and/or reducing the irradiation time. Using the proposed bending method angles larger than 90 degrees can be formed and the location of the kink can be set accurately. It is also shown that tungsten can be deposited on a substrate by the electron-beam-induced deposition, if the oxygen of the proposed cutting technique is replaced by W(CO)6. In this paper, these three nanofabrication methods were employed in the creation of a two dimensional (2D) nanostructure, the letters N and U, and a three dimensional (3D) nanostructure, the letter N. The 2D letters were constructed from 6 CNTs assembled on a substrate while the 3D letter N was bended from a single CNT and fixed to stand on a substrate. Based on the high performance of the proposed techniques, it is suggested that the cutting, bending, and soldering techniques inside SEM will become widely utilized in the fabrication and assembly of nanodevices and in the characterization of nanomaterials.
An experimental investigation of pulsed laser-assisted machining of AISI 52100 steel
NASA Astrophysics Data System (ADS)
Panjehpour, Afshin; Soleymani Yazdi, Mohammad R.; Shoja-Razavi, Reza
2014-11-01
Grinding and hard turning are widely used for machining of hardened bearing steel parts. Laser-assisted machining (LAM) has emerged as an efficient alternative to grinding and hard turning for hardened steel parts. In most cases, continuous-wave lasers were used as a heat source to cause localized heating prior to material removal by a cutting tool. In this study, an experimental investigation of pulsed laser-assisted machining of AISI 52100 bearing steel was conducted. The effects of process parameters (i.e., laser mean power, pulse frequency, pulse energy, cutting speed and feed rate) on state variables (i.e., material removal temperature, specific cutting energy, surface roughness, microstructure, tool wear and chip formation) were investigated. At laser mean power of 425 W with frequency of 120 Hz and cutting speed of 70 m/min, the benefit of LAM was shown by 25% decrease in specific cutting energy and 18% improvement in surface roughness, as compared to those of the conventional machining. It was shown that at constant laser power, the increase of laser pulse energy causes the rapid increase in tool wear rate. Pulsed laser allowed efficient control of surface temperature and heat penetration in material removal region. Examination of the machined subsurface microstructure and microhardness profiles showed no change under LAM and conventional machining. Continuous chips with more uniform plastic deformation were produced in LAM.
Femtosecond laser cutting of human corneas for the subbasal nerve plexus evaluation.
Kowtharapu, B S; Marfurt, C; Hovakimyan, M; Will, F; Richter, H; Wree, A; Stachs, O; Guthoff, R F
2017-01-01
Assessment of various morphological parameters of the corneal subbasal nerve plexus is a valuable method of documenting the structural and presumably functional integrity of the corneal innervation in health and disease. The aim of this work is to establish a rapid, reliable and reproducible method for visualization of the human corneal SBP using femtosecond laser cut corneal tissue sections. Trephined healthy corneal buttons were fixed and processed using TissueSurgeon-a femtosecond laser based microtome, to obtain thick tissue sections of the corneal epithelium and anterior stroma cut parallel to the ocular surface within approximately 15 min. A near infrared femtosecond laser was focused on to the cornea approximately 70-90 μm from the anterior surface to induce material separation using TissueSurgeon. The obtained corneal sections were stained following standard immunohistochemical procedures with anti-neuronal β-III tubulin antibody for visualization of the corneal nerves. Sections that contained the epithelium and approximately 20-30 μm of anterior stroma yielded excellent visualisation of the SBP with minimal optical interference from underlying stromal nerves. In conclusion, the results of this study have demonstrated that femtosecond laser cutting of the human cornea offers greater speed, ease and reliability than standard tissue preparation methods for obtaining high quality thick sections of the anterior cornea cut parallel to the ocular surface. © 2016 The Authors Journal of Microscopy © 2016 Royal Microscopical Society.
Waghmare, Roji B; Annapure, Uday S
2017-10-01
The aim of this study was to determine the potential of hydrogen peroxide (H 2 O 2 ) and modified atmosphere packaging (MAP) on quality of fresh-cut cluster beans. Fresh-cut cluster beans were dipped in a solution of 2% H 2 O 2 for 2 min, packed in an atmosphere of (5% O 2 , 10% CO 2 , 85% N 2 ) and stored in polypropylene bags at 5 °C for 35 days. Passive MAP was created by consuming O 2 and producing CO 2 by fresh-cut cluster beans. The combined effect of H 2 O 2 and MAP on physico-chemical analysis (Headspace gas, weight loss, chlorophyll, hardness and color), microbial quality (mesophilic aerobics and yeasts and molds) and sensory analysis were studied. Chemical treatment and MAP both are equally effective in extending the shelf life at 5 °C for 28 days. Hence, MAP can be an alternative for chemical treatment to achieve a shelf life of 28 days for fresh-cut cluster beans. Control samples, without chemical treatment and modified atmosphere, stored at 5 °C were spoiled after 14 days. Chemical treatment followed by MAP underwent minimum changes in weight, chlorophyll, hardness and color of fresh-cut cluster beans. Combination treatment gives a storage life of 35 days.
Plash, Walker B; Diedrich, André; Biaggioni, Italo; Garland, Emily M; Paranjape, Sachin Y; Black, Bonnie K; Dupont, William D; Raj, Satish R
2013-01-01
POTS (postural tachycardia syndrome) is characterized by an increased heart rate (ΔHR) of ≥30 bpm (beats/min) with symptoms related to upright posture. Active stand (STAND) and passive head-up tilt (TILT) produce different physiological responses. We hypothesized these different responses would affect the ability of individuals to achieve the POTS HR increase criterion. Patients with POTS (n=15) and healthy controls (n=15) underwent 30 min of tilt and stand testing. ΔHR values were analysed at 5 min intervals. ROC (receiver operating characteristic) analysis was performed to determine optimal cut point values of ΔHR for both tilt and stand. Tilt produced larger ΔHR than stand for all 5 min intervals from 5 min (38±3 bpm compared with 33±3 bpm; P=0.03) to 30 min (51±3 bpm compared with 38±3 bpm; P<0.001). Sn (sensitivity) of the 30 bpm criterion was similar for all tests (TILT10=93%, STAND10=87%, TILT30=100%, and STAND30=93%). Sp (specificity) of the 30 bpm criterion was less at both 10 and 30 min for tilt (TILT10=40%, TILT30=20%) than stand (STAND10=67%, STAND30=53%). The optimal ΔHR to discriminate POTS at 10 min were 38 bpm (TILT) and 29 bpm (STAND), and at 30 min were 47 bpm (TILT) and 34 bpm (STAND). Orthostatic tachycardia was greater for tilt (with lower Sp for POTS diagnosis) than stand at 10 and 30 min. The 30 bpm ΔHR criterion is not suitable for 30 min tilt. Diagnosis of POTS should consider orthostatic intolerance criteria and not be based solely on orthostatic tachycardia regardless of test used.
DOT National Transportation Integrated Search
2015-10-01
At present, there is little fundamental guidance available to assist contractors in choosing when to schedule saw cuts on joints. To : conduct pavement finishing and sawing activities effectively, however, contractors need to know when a concrete mix...
Short-term vs. long-term heart rate variability in ischemic cardiomyopathy risk stratification.
Voss, Andreas; Schroeder, Rico; Vallverdú, Montserrat; Schulz, Steffen; Cygankiewicz, Iwona; Vázquez, Rafael; Bayés de Luna, Antoni; Caminal, Pere
2013-01-01
In industrialized countries with aging populations, heart failure affects 0.3-2% of the general population. The investigation of 24 h-ECG recordings revealed the potential of nonlinear indices of heart rate variability (HRV) for enhanced risk stratification in patients with ischemic heart failure (IHF). However, long-term analyses are time-consuming, expensive, and delay the initial diagnosis. The objective of this study was to investigate whether 30 min short-term HRV analysis is sufficient for comparable risk stratification in IHF in comparison to 24 h-HRV analysis. From 256 IHF patients [221 at low risk (IHFLR) and 35 at high risk (IHFHR)] (a) 24 h beat-to-beat time series (b) the first 30 min segment (c) the 30 min most stationary day segment and (d) the 30 min most stationary night segment were investigated. We calculated linear (time and frequency domain) and nonlinear HRV analysis indices. Optimal parameter sets for risk stratification in IHF were determined for 24 h and for each 30 min segment by applying discriminant analysis on significant clinical and non-clinical indices. Long- and short-term HRV indices from frequency domain and particularly from nonlinear dynamics revealed high univariate significances (p < 0.01) discriminating between IHFLR and IHFHR. For multivariate risk stratification, optimal mixed parameter sets consisting of 5 indices (clinical and nonlinear) achieved 80.4% AUC (area under the curve of receiver operating characteristics) from 24 h HRV analysis, 84.3% AUC from first 30 min, 82.2 % AUC from daytime 30 min and 81.7% AUC from nighttime 30 min. The optimal parameter set obtained from the first 30 min showed nearly the same classification power when compared to the optimal 24 h-parameter set. As results from stationary daytime and nighttime, 30 min segments indicate that short-term analyses of 30 min may provide at least a comparable risk stratification power in IHF in comparison to a 24 h analysis period.
Parente, Alberto; Perez-Egido, Laura; Romero, Rosa Maria; Ortiz, Ruben; Burgos, Laura; Angulo, Jose Maria
2016-01-01
The aim of this study is to analyze results of retrograde endopyelotomy with cutting balloon for treatment of ureteropelvic junction obstruction (UPJO) in infants. We routinely treat patients with UPJO under 18 months of age with retrograde high-pressure balloon dilatation of the pelviureteric junction (PUJ). During the procedure, in these cases where narrowing at the PUJ persists, endopyelotomy with cutting balloon is performed. Endopyelotomy is performed over guidewire with 5-mm Cutting Balloon™ under fluoroscopic control. Double-J stents is left in situ for 4 weeks. We retrospectively analyzed the postoperative, clinical, and radiological outcome infants treated with cutting balloon endopyelotomy between 2007 and 2015. Sixteen patients required cutting balloon endopyelotomy to achieve complete resolution of narrowing of the waist observed during high-pressure balloon dilatation of the PUJ. Mean operative time was 35 ± 21 min (mean ± SD) and hospital stay was <24 h in all patients. Complete resolution of the narrowing at the PUJ under fluoroscopy was achieved in all cases, with no perioperative complications. One patient presented with urinary tract infection, postoperatively (Clavien grade II). Preoperatively, all cases had grade IV SFU hydronephrosis with parenchymal thinning. During follow-up, resolution of the hydronephrosis was observed in 11 patients (grade I SFU). In four infants, there was an improvement of the hydronephrosis (grade II SFU) and the renogram curve. In one case, an open pyeloplasty was required due to persistent hydronephrosis and obstructive curve. We believe that endopyelotomy with cutting balloon could be a valid and safe option in minimally invasive management of UPJO in infants.
Determination of laser cutting process conditions using the preference selection index method
NASA Astrophysics Data System (ADS)
Madić, Miloš; Antucheviciene, Jurgita; Radovanović, Miroslav; Petković, Dušan
2017-03-01
Determination of adequate parameter settings for improvement of multiple quality and productivity characteristics at the same time is of great practical importance in laser cutting. This paper discusses the application of the preference selection index (PSI) method for discrete optimization of the CO2 laser cutting of stainless steel. The main motivation for application of the PSI method is that it represents an almost unexplored multi-criteria decision making (MCDM) method, and moreover, this method does not require assessment of the considered criteria relative significances. After reviewing and comparing the existing approaches for determination of laser cutting parameter settings, the application of the PSI method was explained in detail. Experiment realization was conducted by using Taguchi's L27 orthogonal array. Roughness of the cut surface, heat affected zone (HAZ), kerf width and material removal rate (MRR) were considered as optimization criteria. The proposed methodology is found to be very useful in real manufacturing environment since it involves simple calculations which are easy to understand and implement. However, while applying the PSI method it was observed that it can not be useful in situations where there exist a large number of alternatives which have attribute values (performances) very close to those which are preferred.
Pattern-set generation algorithm for the one-dimensional multiple stock sizes cutting stock problem
NASA Astrophysics Data System (ADS)
Cui, Yaodong; Cui, Yi-Ping; Zhao, Zhigang
2015-09-01
A pattern-set generation algorithm (PSG) for the one-dimensional multiple stock sizes cutting stock problem (1DMSSCSP) is presented. The solution process contains two stages. In the first stage, the PSG solves the residual problems repeatedly to generate the patterns in the pattern set, where each residual problem is solved by the column-generation approach, and each pattern is generated by solving a single large object placement problem. In the second stage, the integer linear programming model of the 1DMSSCSP is solved using a commercial solver, where only the patterns in the pattern set are considered. The computational results of benchmark instances indicate that the PSG outperforms existing heuristic algorithms and rivals the exact algorithm in solution quality.
USDA Nutrient Data Set for Retail Veal Cuts
USDA-ARS?s Scientific Manuscript database
The U.S. Department of Agriculture (USDA) Nutrient Data Laboratory (NDL), in collaboration with Colorado State University, conducted a research study designed to update and expand the data on veal cuts in the USDA National Nutrient Database for Standard Reference (SR). This research has been necess...
Smith, P; Endris, R; Kronvall, G; Thomas, V; Verner-Jeffreys, D; Wilhelm, C; Dalsgaard, I
2016-02-01
Epidemiological cut-off values were developed for application to antibiotic susceptibility data for Flavobacterium psychrophilum generated by standard CLSI test protocols. The MIC values for ten antibiotic agents against Flavobacterium psychrophilum were determined in two laboratories. For five antibiotics, the data sets were of sufficient quality and quantity to allow the setting of valid epidemiological cut-off values. For these agents, the cut-off values, calculated by the application of the statistically based normalized resistance interpretation method, were ≤16 mg L(-1) for erythromycin, ≤2 mg L(-1) for florfenicol, ≤0.025 mg L(-1) for oxolinic acid (OXO), ≤0.125 mg L(-1) for oxytetracycline and ≤20 (1/19) mg L(-1) for trimethoprim/sulphamethoxazole. For ampicillin and amoxicillin, the majority of putative wild-type observations were 'off scale', and therefore, statistically valid cut-off values could not be calculated. For ormetoprim/sulphadimethoxine, the data were excessively diverse and a valid cut-off could not be determined. For flumequine, the putative wild-type data were extremely skewed, and for enrofloxacin, there was inadequate separation in the MIC values for putative wild-type and non-wild-type strains. It is argued that the adoption of OXO as a class representative for the quinolone group would be a valid method of determining susceptibilities to these agents. © 2014 John Wiley & Sons Ltd.
Jambassi Filho, José Claudio; Gurjão, André Luiz Demantova; Ceccato, Marilia; Prado, Alexandre Konig Garcia; Gallo, Luiza Herminia; Gobbi, Sebastião
2017-09-01
This study investigated the chronic effects of different rest intervals (RIs) between sets on dynamic and isometric muscle strength and muscle activity. We used a repeated-measures design (pretraining and posttraining) with independent groups (different RI). Twenty-one resistance-trained older women (66.4 ± 4.4 years) were randomly assigned to either a 1-minute RI group (G-1 min; n = 10) or 3-minute RI group (G-3 min; n = 11). Both groups completed 3 supervised sessions per week during 8 weeks. In each session, participants performed 3 sets of 15 repetitions of leg press exercise, with a load that elicited muscle failure in the third set. Fifteen maximum repetitions, maximal voluntary contraction, peak rate of force development, and integrated electromyography activity of the vastus lateralis and vastus medialis muscles were assessed pretraining and posttraining. There was a significant increase in load of 15 maximum repetitions posttraining for G-3 min only (3.6%; P < 0.05). However, posttraining results showed no significant differences between G-1 min and G-3 min groups for all dependent variables (P > 0.05). The findings suggest that different RIs between sets did not influence dynamic and isometric muscle strength and muscle activity in resistance-trained older women.
Bayesian segmentation of atrium wall using globally-optimal graph cuts on 3D meshes.
Veni, Gopalkrishna; Fu, Zhisong; Awate, Suyash P; Whitaker, Ross T
2013-01-01
Efficient segmentation of the left atrium (LA) wall from delayed enhancement MRI is challenging due to inconsistent contrast, combined with noise, and high variation in atrial shape and size. We present a surface-detection method that is capable of extracting the atrial wall by computing an optimal a-posteriori estimate. This estimation is done on a set of nested meshes, constructed from an ensemble of segmented training images, and graph cuts on an associated multi-column, proper-ordered graph. The graph/mesh is a part of a template/model that has an associated set of learned intensity features. When this mesh is overlaid onto a test image, it produces a set of costs which lead to an optimal segmentation. The 3D mesh has an associated weighted, directed multi-column graph with edges that encode smoothness and inter-surface penalties. Unlike previous graph-cut methods that impose hard constraints on the surface properties, the proposed method follows from a Bayesian formulation resulting in soft penalties on spatial variation of the cuts through the mesh. The novelty of this method also lies in the construction of proper-ordered graphs on complex shapes for choosing among distinct classes of base shapes for automatic LA segmentation. We evaluate the proposed segmentation framework on simulated and clinical cardiac MRI.
Laser cutting metallic plates using a 2kW direct diode laser source
NASA Astrophysics Data System (ADS)
Fallahi Sichani, E.; Hauschild, D.; Meinschien, J.; Powell, J.; Assunção, E. G.; Blackburn, J.; Khan, A. H.; Kong, C. Y.
2015-07-01
This paper investigates the feasibility of using a 2kW direct diode laser source for producing high-quality cuts in a variety of materials. Cutting trials were performed in a two-stage experimental procedure. The first phase of trials was based on a one-factor-at-a-time change of process parameters aimed at exploring the process window and finding a semi-optimum set of parameters for each material/thickness combination. In the second phase, a full factorial experimental matrix was performed for each material and thickness, as a result of which, the optimum cutting parameters were identified. Characteristic values of the optimum cuts were then measured as per BS EN ISO 9013:2002.
Machinability of CAD-CAM materials.
Chavali, Ramakiran; Nejat, Amir H; Lawson, Nathaniel C
2017-08-01
Although new materials are available for computer-aided design and computer-aided manufacturing (CAD-CAM) fabrication, limited information is available regarding their machinability. The depth of penetration of a milling tool into a material during a timed milling cycle may indicate its machinability. The purpose of this in vitro study was to compare the tool penetration rate for 2 polymer-containing CAD-CAM materials (Lava Ultimate and Enamic) and 2 ceramic-based CAD-CAM materials (e.max CAD and Celtra Duo). The materials were sectioned into 4-mm-thick specimens (n=5/material) and polished with 320-grit SiC paper. Each specimen was loaded into a custom milling apparatus. The apparatus pushed the specimens against a milling tool (E4D Tapered 2016000) rotating at 40 000 RPM with a constant force of 0.98 N. After a 6-minute timed milling cycle, the length of each milling cut was measured with image analysis software under a digital light microscope. Representative specimens and milling tools were examined with scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy. The penetration rate of Lava Ultimate (3.21 ±0.46 mm/min) and Enamic (2.53 ±0.57 mm/min) was significantly greater than that of e.max CAD (1.12 ±0.32 mm/min) or Celtra Duo (0.80 ±0.21 mm/min) materials. SEM observations showed little tool damage, regardless of material type. Residual material was found on the tools used with polymer-containing materials, and wear of the embedding medium was seen on the tools used with the ceramic-based materials. Edge chipping was noted on cuts made in the ceramic-based materials. Lava Ultimate and Enamic have greater machinability and less edge chipping than e.max CAD and Celtra Duo. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Novel use of an ultrasonic bone-cutting device for endoscopic-assisted craniosynostosis surgery.
Chaichana, Kaisorn L; Jallo, George I; Dorafshar, Amir H; Ahn, Edward S
2013-07-01
Endoscopic-assisted craniosynostosis surgery is associated with less blood loss and shorter operative times as compared to open surgery. However, in infants who have low circulating blood volumes, the endoscopic approach is still associated with significant blood loss. A major source of blood loss is the bone that is cut during surgery. We discuss the novel use of an ultrasonic bone-cutting device for craniosynostosis surgery, which decreases bone bleeding. This device, which has primarily only been used for spine and skull base surgery, may help reduce blood loss in these infants. All patients with single suture craniosynostosis who were operated on with the use of an ultrasonic bone-cutting device were identified. The information retrospectively recorded from patient charts included patient age, suture involved, blood loss, operative times, complications, preoperative hemoglobin, postoperative hemoglobin, length of hospital stay, and follow-up times. Thirteen patients (12 males, 1 female) underwent surgery with an ultrasonic bone-cutting device during the reviewed period. The average age (±standard deviation) of the patients was 11.8 (±1.6) weeks. Four patients had metopic synostosis and nine patients had sagittal synostosis. The average surgery time was 84 (±13) min. The median (interquartile range) blood loss was 20 (10-70) cc. No patients required blood transfusions. Three patients had dural tears. We demonstrate the novel use of an ultrasonic bone-cutting device for endoscopic-assisted craniosynostosis surgery. This device limited blood loss while maintaining short operative times for infants with low circulating blood volumes.
NASA Astrophysics Data System (ADS)
Kalejs, J. P.
1994-01-01
Mobil Solar Energy Corporation currently practices a unique crystal growth technology for producing crystalline silicon sheet, which is then cut with lasers into wafers. The wafers are processed into solar cells and incorporated into modules for photovoltaic applications. The silicon sheet is produced using a method known as Edge-defined Film-fed growth (EFG), in the form of hollow eight-sided polygons (octagons) with 10 cm faces. These are grown to lengths of 5 meters and thickness of 300 microns, with continuous melt replenishment, in compact furnaces designed to operate at a high sheet area production area of 135 sq cm/min. The present Photovoltaic Manufacturing Technology (PVMaT) three-year program seeks to advance the manufacturing line capabilities of the Mobil Solar crystal growth and cutting technologies. If successful, these advancements will provide significant reductions in already low silicon raw material usage, improve process productivity, laser cutting throughput and yield, and so lower both individual wafer cost and the cost of module production. This report summarizes the significant technical improvements in EFG technology achieved in Phase 1 of this program. Technical results are reported for each of the three main program areas: (1) thin octagon growth (crystal growth) -- to reduce the thickness of the octagon to an interim goal of 250 microns during Phase 1, with an ultimate goal of achieving 200 micron thicknesses; (2) laser cutting -- to improve the laser cutting process, so as to produce wafers with decreased laser cutting damage at increased wafer throughput rates; and (3) process control and product specification -- to implement advanced strategies in crystal growth process control and productivity designed to increase wafer yields.
ADVANCED CUTTINGS TRANSPORT STUDY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stefan Miska; Nicholas Takach; Kaveh Ashenayi
2004-07-31
We have tested the loop elevation system. We raised the mast to approximately 25 to 30 degrees from horizontal. All went well. However, while lowering the mast, it moved laterally a couple of degrees. Upon visual inspection, severe spalling of the concrete on the face of the support pillar, and deformation of the steel support structure was observed. At this time, the facility is ready for testing in the horizontal position. A new air compressor has been received and set in place for the ACTS test loop. A new laboratory has been built near the ACTS test loop Roughened cupsmore » and rotors for the viscometer (RS300) were obtained. Rheologies of aqueous foams were measured using three different cup-rotor assemblies that have different surface roughness. The relationship between surface roughness and foam rheology was investigated. Re-calibration of nuclear densitometers has been finished. The re-calibration was also performed with 1% surfactant foam. A new cuttings injection system was installed at the bottom of the injection tower. It replaced the previous injection auger. A mechanistic model for cuttings transport with aerated mud has been developed. Cuttings transport mechanisms with aerated water at various conditions were experimentally investigated. A total of 39 tests were performed. Comparisons between the model predictions and experimental measurements show a satisfactory agreement. Results from the ultrasonic monitoring system indicated that we could distinguish between different sand levels. We also have devised ways to achieve consistency of performance by securing the sensors in the caps in exactly the same manner as long as the sensors are not removed from the caps. A preliminary test was conducted on the main flow loop at 100 gpm flow rate and 20 lb/min cuttings injection rate. The measured bed thickness using the ultrasonic method showed a satisfactory agreement with nuclear densitometer readings. Thirty different data points were collected after the test section was put into liquid holdup mode. Readings indicated 2.5 to 2.7 inches of sand. The corresponding nuclear densitometers readings were between 2.5 and 3.1 inches. Lab tests were conducted to check an on-line viewing system. Sharp images were obtained through a CCD camera with the use of a ring light or fiber light. A prototype device for measuring the average bubble size for the foam generator-viscometer was constructed from a 1/2 inch fitting. The new windowed cell has been received and installed on the ACTF Bubble Characterization Cart.« less
Diagnosing Postural Tachycardia Syndrome: Comparison of Tilt Test versus Standing Hemodynamics
Plash, Walker B; Diedrich, André; Biaggioni, Italo; Garland, Emily M; Paranjape, Sachin Y; Black, Bonnie K; Dupont, William D; Raj, Satish R
2012-01-01
Postural tachycardia syndrome (POTS) is characterized by increased heart rate (ΔHR) of ≥30 bpm with symptoms related to upright posture. Active stand (STAND) and passive head-up tilt (TILT) produce different physiological responses. We hypothesized these different responses would affect the ability of individuals to achieve the POTS HR increase criterion. Patients with POTS (n=15) and healthy controls (n=15) underwent 30 min of TILT and STAND testing. ΔHR values were analyzed at 5 min intervals. Receiver Operating Characteristics analysis was performed to determine optimal cut point values of ΔHR for both TILT and STAND. TILT produced larger ΔHR than STAND for all 5 min intervals from 5 min (38±3 bpm vs. 33±3 bpm; P=0.03) to 30 min (51±3 bpm vs. 38±3 bpm; P<0.001). Sensitivity (Sn) of the 30 bpm criterion was similar for all tests (TILT-10=93%, STAND-10=87%, TILT30=100%, and STAND30=93%). Specificity (Sp) of the 30 bpm criterion was less at both 10 and 30 min for TILT (TILT10=40%, TILT30=20%) than STAND (STAND10=67%, STAND30=53%). The optimal ΔHR to discriminate POTS at 10 min were 38 bpm (TILT) and 29 bpm (STAND), and at 30 min were 47 bpm (TILT) and 34 bpm (STAND). Orthostatic tachycardia was greater for TILT (with lower specificity for POTS diagnosis) than STAND at 10 and 30 min. The 30 bpm ΔHR criterion is not suitable for 30 min TILT. Diagnosis of POTS should consider orthostatic intolerance criteria and not be based solely on orthostatic tachycardia regardless of test used. PMID:22931296
Effect of Cutting Tool Properties and Depth of Cut in Rock Cutting: An Experimental Study
NASA Astrophysics Data System (ADS)
Rostamsowlat, Iman
2018-06-01
The current paper is designed to investigate the effect of worn (blunt) polycrystalline diamond compact cutter properties on both the contact stress (σ) and friction coefficient ( μ) mobilized at the wear flat-rock interface at different inclination angles of the wear flat surface and at a wide range of depths of cut. An extensive and comprehensive set of cutting experiments is carried out on two sedimentary rocks (one limestone and one sandstone) using a state-of-the-art rock cutting equipment (Wombat) and various blunt cutters. Experiments with blunt cutters are characterized by different wear flat inclination angles (β), different wear flat surface roughness (Ra), different wear flat material, and different cutting tool velocities ({\\varvec{v}}) were conducted. The experimental results show that both the contact stress and friction coefficient are predominantly affected by the wear flat roughness at all inclination angles of the wear flat; however, the cutting tool velocity has a negligible influence on both the contact stress and friction coefficient. Further investigations suggest that the contact stress is greatly affected by the depth of cut within the plastic regime of frictional contact while the contact stress is insensitive to the depth of cut within the elastic regime.
32 CFR 644.504 - Disposal plan for timber.
Code of Federal Regulations, 2011 CFR
2011-07-01
... merchantable dead timber will be marked for cutting in accordance with the land management plan, Master Plan, or forestry supplement thereto, and cutting will be limited to the timber so marked. The disposal... affecting the installations, and the requirements of such measures will be set forth specifically. (e) Any...
Mansur, Ahmad Rois; Oh, Deog-Hwan
2015-06-01
This study evaluated the efficacy of individual treatments (thermosonication [TS+DW] and slightly acidic electrolyzed water [SAcEW]) and their combination on reducing Escherichia coli O157:H7, Listeria monocytogenes, and spoilage microorganisms (total bacterial counts [TBC], Enterobacteriaceae, Pseudomonas spp., and yeast and mold counts [YMC]) on fresh-cut kale. For comparison, the antimicrobial efficacies of sodium chlorite (SC; 100 mg/L) and sodium hypochlorite (SH; 100 mg/L) were also evaluated. Each 10 g sample of kale leaves was inoculated to contain approximately 6 log CFU/g of E. coli O157:H7 or L. monocytogenes. Each inoculated or uninoculated samples was then dip treated with deionized water (DW; control), TS+DW, and SAcEW at various treatment conditions (temperature, physicochemical properties, and time) to assess the efficacy of each individual treatment. The efficacy of TS+DW or SAcEW was enhanced at 40 °C for 3 min, with an acoustic energy density of 400 W/L for TS+DW and available chlorine concentration of 5 mg/L for SAcEW. At 40 °C for 3 min, combined treatment of thermosonication 400 W/L and SAcEW 5 mg/L (TS+SAcEW) was more effective in reducing microorganisms compared to the individual treatments (SAcEW, SC, SH, and TS+DW) and combined treatments (TS+SC and TS+SH), which significantly (P < 0.05) reduced E. coli O157:H7, L. monocytogenes, TBC, Enterobacteriaceae, Pseudomonas spp., and YMC by 3.32, 3.11, 3.97, 3.66, 3.62, and >3.24 log CFU/g, respectively. The results suggest that the combined treatment of TS+SAcEW has the potential as a decontamination process in fresh-cut industry. © 2015 Institute of Food Technologists®
Elsharkawy, Aisha; Alboraie, Mohamed; Fouad, Rabab; Asem, Noha; Abdo, Mahmoud; Elmakhzangy, Hesham; Mehrez, Mai; Khattab, Hany; Esmat, Gamal
2017-12-01
Transient elastography is widely used to assess fibrosis stage in chronic hepatitis C (CHC). We aimed to establish and validate different transient elastography cut-off values for significant fibrosis and cirrhosis in CHC genotype 4 patients. The data of 100 treatment-naive CHC patients (training set) and 652 patients (validation set) were analysed. The patients were subjected to routine pretreatment laboratory investigations, liver biopsy and histopathological staging of hepatic fibrosis according to the METAVIR scoring system. Transient elastography was performed before and in the same week as liver biopsy using FibroScan (Echosens, Paris, France). Transient elastography results were correlated to different stages of hepatic fibrosis in both the training and validation sets. ROC curves were constructed. In the training set, the best transient elastography cut-off values for significant hepatic fibrosis (≥F2 METAVIR), advanced hepatic fibrosis (≥F3 METAVIR) and cirrhosis (F4 METAVIR) were 7.1, 9 and 12.2 kPa, with sensitivities of 87%, 87.5% and 90.9% and specificities of 100%, 99.9% and 99.9%, respectively. The application of these cut-offs in the validation set showed sensitivities of 85.5%, 82.8% and 92% and specificities of 86%, 89.4% and 99.01% for significant hepatic fibrosis, advanced hepatic fibrosis and cirrhosis, respectively. Transient elastography performs well for significant hepatic fibrosis, advanced hepatic fibrosis and cirrhosis, with validated cut-offs of 7.1, 9 and 12.2 kPa, respectively, in genotype 4 CHC patients. Copyright © 2017 Pan-Arab Association of Gastroenterology. Published by Elsevier B.V. All rights reserved.
Higher Education Faculty Engagement in a Modified Mapmark Standard Setting
ERIC Educational Resources Information Center
Horst, S. Jeanne; DeMars, Christine E.
2016-01-01
The Mapmark standard setting method was adapted to a higher education setting in which faculty leaders were highly involved. Eighteen university faculty members participated in a day-long standard setting for a general education communications test. In Round 1, faculty set initial cut-scores for each of four student learning objectives. In Rounds…
Jiao, W; Zhao, Y; Xuan, Y; Wang, M
2015-02-01
For thoracoscopic upper lobectomies, most cutting endostaplers must be inserted through the camera port when using a two-port approach. Access to the hilar vasculature through only the utility port remains a challenge. In this study, we describe a procedure to access the hilar vasculature without transferring the endostapler site during a thoracoscopic right upper lobectomy. A 2.5-cm utility anterior incision was made in the fourth intercostal space. The posterior mediastinal visceral pleura were dissected to expose the posterior portion of the right upper bronchus and the anterior trunk of the right pulmonary artery. The pleura over the right hilar vasculature were then peeled with an electrocoagulation hook. The anterior trunk of the right pulmonary artery was then transected with a cutting endostapler through the utility port firstly. This crucial maneuver allowed the endostapler access to the right upper lobe pulmonary vein. The hilar structures were then easily handled in turn. This novel technique was performed successfully in 32 patients, with no perioperative deaths. The average operation time was 120.6 min (range 75-180 min). This novel technique permits effective control of the hilar vessels through the utility port, enabling simple, safe, quick and effective resection.
Krzemińska, Sylwia; Rzymski, Władysław M.; Malesa, Monika; Borkowska, Urszula; Oleksy, Mariusz
2016-01-01
Resistance to permeation of noxious chemical substances should be accompanied by resistance to mechanical factors because the glove material may be torn, cut or punctured in the workplace. This study reports on glove materials, protecting against mineral oils and mechanical hazards, made of carboxylated acrylonitrile–butadiene rubber (XNBR) latex. The obtained materials were characterized by a very high resistance of the produced materials to oil permeation (breakthrough time > 480 min). The mechanical properties, and especially tear resistance, of the studied materials were improved after the addition of modified bentonite (nanofiller) to the XNBR latex mixture. The nanocomposite meets the requirements in terms of parameters characterizing tear, abrasion, cut and puncture resistance. Therefore, the developed material may be used for the production of multifunctional protective gloves. PMID:26757889
Heart rate recovery, exercise capacity, and mortality risk in male veterans.
Kokkinos, Peter; Myers, Jonathan; Doumas, Michael; Faselis, Charles; Pittaras, Andreas; Manolis, Athanasios; Kokkinos, John Peter; Narayan, Puneet; Papademetriou, Vasilios; Fletcher, Ross
2012-04-01
Both impaired heart rate recovery (HRR) and low fitness are associated with higher mortality risk. In addition, HRR is influenced by fitness status. The interaction between HRR, mortality, and fitness has not been clearly defined. Thus, we sought to evaluate the association between HRR and all-cause mortality and to assess the effects of fitness on this association. Treadmill exercise testing was performed in 5974 male veterans for clinical reasons at two Veterans Affairs Medical Centers (Washington, DC and Palo Alto, CA). HRR was calculated at 1 and 2 min of recovery. All-cause mortality was determined over a mean 6.2-year follow-up period. Mortality risk was significantly and inversely associated with HRR, only at 2 min. A cut-off value of 14 beats/min at 2 min recovery was the strongest predictor of mortality for the cohort (hazard ratio = 2.4; CI 1.6-3.5). The mortality risk was overestimated when exercise capacity was not considered. When both low fitness and low HRR were present (≤6 metabolic equivalents and ≤14 beats/min), mortality risk was approximately seven-fold higher compared to the High-fit + High-HRR group (>6 metabolic equivalents and >14 beats/min). HRR at 2 min post exercise is strongly and inversely associated with all-cause mortality. Exercise capacity affects HRR-associated mortality substantially and should be considered when applying HRR to estimate mortality.
Pereira, Catarina L N; Baptista, Fátima; Infante, Paulo
2014-01-01
This study examined the effect of the type, level and amount of physical activity in falls and fall-related injuries. Participants were 506 community-dwelling adults aged >50 years (390 women: 67.7 ± 6.8 years and 116 men: 69.6 ± 6.6 years). Falls, fall-related injuries (slight and severe), and physical activity (type, level and energy expenditure) were evaluated by questionnaires. Confounders included co-morbidities, fear of falling, environmental hazards and physical fitness. After adjustment for confounders, logistic analysis revealed that the likelihood of falling decreased by 2% for each 100 metabolic expenditure (MET-min/week) of total physical activity and increased by 5% for each 100 MET-min/week of vigorous-intensity physical activity; total physical activity >1125 MET-min/week and vigorous physical activity <500 MET-min/week were identified as cut-off values discriminating non-fallers from fallers. Compared to the low physical activity level, increased physical activity levels diminished the likelihood of the occurrence of severe fall-related injuries by 76% (moderate) and 58% (high; p < 0.05) in fallers. Being active, especially sufficiently active, reduces fall-related injuries by decreasing falls and by safeguarding against severe injuries when falls occur. At least 1125 MET-min/week of total physical activity including >500 MET-min/week of vigorous intensity seems to prevent falls and, therefore, fall-related injuries.
How Do River Meanders Change with Sea Level Rise and Fall?
NASA Astrophysics Data System (ADS)
Scamardo, J. E.; Kim, W.
2016-12-01
River meander patterns are controlled by numerous factors, including variations in water discharge, sediment input, and base level. However, the effect of sea level rise and fall on meandering rivers has not been thoroughly quantified. This study examines geomorphic changes to meandering rivers as a result of sea level rise and fall. Twenty experimental runs using coarse-grained walnut shell sediment (D50= 500 microns) in a flume tank (2.4m x 0.6m x 0.1m) tested the optimal initial conditions for creating meandering rivers in a laboratory setting as well as variations in base level rise and fall rates. Geomorphic changes were recorded by camera images every 20 seconds for a duration of 4 hours per experiment. Seventeen experiments tested the effects of changes in initial base levels, water discharge between 200 and 400 mL/min, and sediment to water input ratios between 1:1000 and 1:250 while measuring sinuosity, channel geometry, and the timescale of the channel to reach a stable form. Sinuosity and channel activity increased with increasing water discharge, initial base level, and the sediment to water ratio to a point after which the activity decreased with increasing sediment input. Base-level change experiments used initial conditions of 400 mL/min, a 1:750 sediment to water input ratio, and a 6 cm initial base-level to induce river meanders for the initial 2 hours before base-level change occurred. Three separate experiments investigated the effects of increasing rates of sea level change: 0.07 cm/min, 0.1 cm/min, and 0.2 cm/min. Experimental sea level was decreased constantly from a high-stand of 6 cm to a low-stand of 2 cm back to the high-stand base-level in each experiment. The rates of change in the experiments scale roughly from central to glacial cycles. In all three experiments, sea level fall induced meander cut-off while sea level rise prompted greater rates of meander bend erosion and meander growth. Sinuosity increased by 12%, 13.5%, and 24%, respectively in the three experiments, with most sinuosity changes occurring in the downstream reach of the channel. These experiments could provide insight into long term effects of sea level change on modern meandering fluvial systems as well as provide a key to interpreting past fluvial changes in the stratigraphic record.
Surface quality and topographic inspection of variable compliance part after precise turning
NASA Astrophysics Data System (ADS)
Nieslony, P.; Krolczyk, G. M.; Wojciechowski, S.; Chudy, R.; Zak, K.; Maruda, R. W.
2018-03-01
The paper presents the problem of precise turning of the mould parts with variable compliance and demonstrates a topographic inspection of the machined surface quality. The study was conducted for the cutting tools made of cemented carbide with coatings, in a range of variable cutting parameters. The long shaft with special axial hole, made of hardened 55NiCrMoV6 steel was selected as a workpiece. The carried out study included the stiffness measurement of the machining system, as well as the investigation of cutting force components. In this context, the surface topography parameters were evaluated using the stylus profile meter and analysed. The research revealed that the surface topography, alongside the 3D functional parameters, and PSD influences the performance of the machined surface. The lowest surface roughness parameters values, equalled to Sa = 1 μm and Sz = 4.3 μm have been obtained during turning with cutting speed vc = 90 m/min. The stable turning of variable compliance part affects the surface texture formation with a unidirectional perpendicular, anisotropic structure. Nevertheless, in case of unstable turning, the characteristic chatter marks are observed, and process dynamics has greater contribution in formation of surface finish than turning kinematics and elastic plastic deformation of workpiece.
Reliability and Validity of 10 Different Standard Setting Procedures.
ERIC Educational Resources Information Center
Halpin, Glennelle; Halpin, Gerald
Research indicating that different cut-off points result from the use of different standard-setting techniques leaves decision makers with a disturbing dilemma: Which standard-setting method is best? This investigation of the reliability and validity of 10 different standard-setting approaches was designed to provide information that might help…
NASA Technical Reports Server (NTRS)
Girala, A. S. (Inventor)
1981-01-01
A self clamping cutting tool which includes a handle attached to a C-shaped housing is described. Rotatably mounted within the housing is a C-shaped tool body carrying a set of clamping rolls, two support rolls, and an edged cutting roll (64). The support rolls are disposed to one side of the axis of a pipe and the cutting roll is disposed to the other side of a pipe axis so that these rolls contact a pipe at three circumferential points. Cutter advancing apparatus advance the cutting roll toward the support rollers. The support rolls and cutting roll are rotatable independently of the C-shaped housing. A one way ratchet mechanism disposed between the C-shaped housing and the C-shaped tool body permits operation by movement in one rotational direction about the pipe axis.
Transport on percolation clusters with power-law distributed bond strengths.
Alava, Mikko; Moukarzel, Cristian F
2003-05-01
The simplest transport problem, namely finding the maximum flow of current, or maxflow, is investigated on critical percolation clusters in two and three dimensions, using a combination of extremal statistics arguments and exact numerical computations, for power-law distributed bond strengths of the type P(sigma) approximately sigma(-alpha). Assuming that only cutting bonds determine the flow, the maxflow critical exponent v is found to be v(alpha)=(d-1)nu+1/(1-alpha). This prediction is confirmed with excellent accuracy using large-scale numerical simulation in two and three dimensions. However, in the region of anomalous bond capacity distributions (0< or =alpha< or =1) we demonstrate that, due to cluster-structure fluctuations, it is not the cutting bonds but the blobs that set the transport properties of the backbone. This "blob dominance" avoids a crossover to a regime where structural details, the distribution of the number of red or cutting bonds, would set the scaling. The restored scaling exponents, however, still follow the simplistic red bond estimate. This is argued to be due to the existence of a hierarchy of so-called minimum cut configurations, for which cutting bonds form the lowest level, and whose transport properties scale all in the same way. We point out the relevance of our findings to other scalar transport problems (i.e., conductivity).
Simulation for Rough Mill Options
Janice K. Wiedenbeck
1992-01-01
How is rough mill production affected by lumber length? Lumber grade? Cutting quality? Cutting sizes? How would equipment purchase plans be prioritized? How do personnel shifts affect system productivity? What effect would a reduction in machine set-up time have on material flow? Simulation modeling is being widely used in many industries to provide valuable insight...
Minimizing Expected Maximum Risk from Cyber-Attacks with Probabilistic Attack Success
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhuiyan, Tanveer H.; Nandi, Apurba; Medal, Hugh
The goal of our work is to enhance network security by generating partial cut-sets, which are a subset of edges that remove paths from initially vulnerable nodes (initial security conditions) to goal nodes (critical assets), on an attack graph given costs for cutting an edge and a limited overall budget.
Metrics for Food Preparation, Baking, Meat Cutting.
ERIC Educational Resources Information Center
Cooper, Gloria S., Ed.; Magisos, Joel H., Ed.
Designed to meet the job-related metric measurement needs of food preparation, baking, meat cutting students, this instructional package is one of five for the home economics occupations cluster, part of a set of 55 packages for metric instruction in different occupations. The package is intended for students who already know the occupational…
ERIC Educational Resources Information Center
Pettifor, Ann
2010-01-01
With the main political parties set on reducing public spending, one might be forgiven for supposing that "savage" cuts are the only way forward. However, the author believes there are alternatives, and that is why public education about the financial system is so important. Today, UK is trying to clear up a mess--a mess made by the…
Mathematical modelling and linear stability analysis of laser fusion cutting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hermanns, Torsten; Schulz, Wolfgang; Vossen, Georg
A model for laser fusion cutting is presented and investigated by linear stability analysis in order to study the tendency for dynamic behavior and subsequent ripple formation. The result is a so called stability function that describes the correlation of the setting values of the process and the process’ amount of dynamic behavior.
Hammer, T; Höche, T; Heichel, J
2018-01-01
Femtosecond lasers (fs-lasers) are established cutting instruments for the creation of LASIK flaps. Previous studies often showed even rougher surfaces after application of fs-laser systems compared to lamellar keratotomy with mechanical microkeratomes. When cutting the cornea with fs-lasers, an intrastromal gas development occurs, which has a potentially negative influence on the cutting quality if the gas cannot be dissipated; therefore, manufacturers have chosen the way of gas assimilation in so-called pockets. The investigated system creates a tunnel which opens under the conjunctiva. The aim of this study was to investigate the effects of a tunnel as well as the influence of different spot distances on the quality of cut surfaces and edges. In this experimental study on freshly enucleated porcine eyes (n = 15), the following cuts were carried out with the FS-200 (Wavelight, Erlangen, Germany): 1. standard setting (spot and line separation 8 µm), 2. with tunnel for gas drainage, 3. without gas-conducting tunnel, 4. with increased spot spacing (spot and line separation 9 μm instead of 8 μm) and 5. with reduced spot spacing (spot and line separation 7 μm instead of 8 μm). Subsequently, scanning electron microscopy (FEI Quanta 650, Hillsboro, OR) of the cut edges and surfaces as well as the gas drain tunnel were performed. The evaluation was based on an established score. The current fs-laser system (200 Hz) is able to create smooth cutting surfaces and sharp edges. The changed density of laser pulses compared to the standard settings with a reduced or increased distance between the pulses, did not achieve any further improvement in the surface quality. The gas-conducting tunnel could be detected by scanning electron microscope. In the case of cutting without a tunnel, roughened surfaces and irregularities on the cutting edges were found. When the FS-200 fs-laser is used, LASIK cuts with very smooth cut surfaces and sharp cutting edges are achieved. This is only valid as long as an additional tunnel with the fs-laser is placed under the conjunctiva. It can be assumed that the resulting gas is effectively drained through this tunnel. The installation of the tunnel represents a new possibility to replace previous techniques of gas assimilation in deeper lying cutting areas.
Isose, Sagiri; Misawa, Sonoko; Sonoo, Masahiro; Shimuzu, Toshio; Oishi, Chizuko; Shibuya, Kazumoto; Nasu, Saiko; Sekiguchi, Yukari; Mitsuma, Satsuki; Beppu, Minako; Omori, Shigeki; Komori, Tetsuo; Kokubun, Norito; Inaba, Akira; Hirashima, Fumiko; Kuwabara, Satoshi
2014-10-01
In current electrodiagnostic criteria for chronic inflammatory demyelinating polyneuropathy, the cutoff values of distal compound muscle action potential (DCMAP) duration are defined using electromyogram low-cut filter setting of 20 Hz. We aimed to assess effects of low-cut filter on DCMAP duration (10 vs. 20 Hz). We prospectively measured DCMAP duration in 130 normal controls and 42 patients, fulfilling diagnostic criteria for typical chronic inflammatory demyelinating polyneuropathy by European Federation of Neurological Societies/Peripheral Nerve Society. Distal compound muscle action potential duration was significantly shortened with 20-Hz than 10-Hz filtering. When the cutoff values were defined as the upper limit of normal (ULN, mean + 2.5SD), the sensitivity/specificity was 67%/95% in 10-Hz recordings, and 69%/95% in 20-Hz recordings. This diagnostic accuracy was similar to that defined by receiver operating characteristic analyses. Distal compound muscle action potential duration significantly affected by the low-cut electromyogram filter setting, but with at least 10 and 20 Hz, the diagnostic accuracy is similar.
Female genital cutting in Hargeisa, Somaliland: is there a move towards less severe forms?
Lunde, Ingvild Bergom; Sagbakken, Mette
2014-05-01
According to several sources, little progress is being made in eliminating the cutting of female genitalia. This paper, based on qualitative interviews and observations, explores perceptions of female genital cutting and elimination of the phenomenon in Hargeisa, Somaliland. Two main groups of participants were interviewed: (1) 22 representatives of organisations whose work directly relates to female genital cutting; and (2) 16 individuals representing different groups of society. It was found that there is an increasing use of medical staff and equipment when a girl undergoes the procedure of female genital cutting; the use of terminology is crucial in understanding current perceptions of female genital cutting; religion is both an important barrier and facilitator of elimination; and finally, traditional gender structures are currently being challenged in Hargeisa. The findings of this study suggest that it is important to consider current perceptions on practices of female genital cutting and on abandonment of female genital cutting, in order to gain useful knowledge on the issue of elimination. The study concludes that elimination of female genital cutting is a multifaceted process which is constantly negotiated in a diversity of social settings. Copyright © 2014 Reproductive Health Matters. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Majumder, Himadri; Maity, Kalipada
2018-03-01
Shape memory alloy has a unique capability to return to its original shape after physical deformation by applying heat or thermo-mechanical or magnetic load. In this experimental investigation, desirability function analysis (DFA), a multi-attribute decision making was utilized to find out the optimum input parameter setting during wire electrical discharge machining (WEDM) of Ni-Ti shape memory alloy. Four critical machining parameters, namely pulse on time (TON), pulse off time (TOFF), wire feed (WF) and wire tension (WT) were taken as machining inputs for the experiments to optimize three interconnected responses like cutting speed, kerf width, and surface roughness. Input parameter combination TON = 120 μs., TOFF = 55 μs., WF = 3 m/min. and WT = 8 kg-F were found to produce the optimum results. The optimum process parameters for each desired response were also attained using Taguchi’s signal-to-noise ratio. Confirmation test has been done to validate the optimum machining parameter combination which affirmed DFA was a competent approach to select optimum input parameters for the ideal response quality for WEDM of Ni-Ti shape memory alloy.
Stress and Strain Distributions during Machining of Ti-6Al-4V at Ambient and Cryogenic Temperatures
NASA Astrophysics Data System (ADS)
Rahman, Md. Fahim
Dry and liquid nitrogen pre-cooled Ti-6Al-4V samples were machined at a cutting speed of 43.2 m/min and at low (0.1 mm/rev) to high (0.4 mm/rev) feed rates for understanding the effects of temperature and strain rate on chip microstructures. During cryogenic machining, it was observed that between feed rates of 0.10 and 0.30 mm/rev, a 25% pressure reduction on tool occurred. Smaller number of chips and low tool/chip contact time and temperature were observed (compared to dry machining under ambient conditions). An in-situ set-up that consisted of a microscope and a lathe was constructed and helped to propose a novel serrated chip formation mechanism when microstructures (strain localization) and surface roughness were considered. Dimpled fracture surfaces observed in high-speed-machined chips were formed due to stable crack propagation that was also recorded during in-situ machining. An instability criterion was developed that showed easier strain localization within the 0.10-0.30mm/rev feed rate range.
The Lacanian Concept of Cut in Light of Lacan's Interactions with Maud Mannoni
Razon, Laure; Putois, Olivier; Vanier, Alain
2017-01-01
This article sets out to shed light on the Lacanian concept of cut (introduced in 1961–1962): it refers to the symbolic (i.e., linguistic) operation which produces the object a and thereby enables separation, through which the subject emerges. To that effect, we show how this concept benefitted from Lacan's interactions with Maud Mannoni (1923-1998), who focused on clinical situations where implementing a cut in the subject's environment is the only way to enable a separation between the child and the Other. Lacan first drew on Mannoni's clinical elaborations about the retarded child's alienation to the maternal fantasy: when the mother's unconscious doesn't leave room for the cut, it prevents the separation through which the child could become a subject. Lacan generalized this in the late 1960s: he broadened Mannoni's alienation to the maternal fantasy to characterize a type of child symptom, where children become their mother's non-separated, de-phallicized object a. Then, in the 1970s, Mannoni proposed an original theoretico-clinical setting to address the configurations where the object a isn't separated: in the splintered institution, the team follows on projects of activities (professional, personal, etc.) outside the institution voiced by children who haven't previously encountered the symbolic cut, by helping them realize these external projects. By thus acknowledging their attempts at establishing a cut and giving them consistency, the splintered institution helps them psychically elaborate separation. PMID:29312050
NASA Astrophysics Data System (ADS)
Copur, Hanifi; Bilgin, Nuh; Balci, Cemal; Tumac, Deniz; Avunduk, Emre
2017-06-01
This study aims at determining the effects of single-, double-, and triple-spiral cutting patterns; the effects of tool cutting speeds on the experimental scale; and the effects of the method of yield estimation on cutting performance by performing a set of full-scale linear cutting tests with a conical cutting tool. The average and maximum normal, cutting and side forces; specific energy; yield; and coarseness index are measured and compared in each cutting pattern at a 25-mm line spacing, at varying depths of cut per revolution, and using two cutting speeds on five different rock samples. The results indicate that the optimum specific energy decreases by approximately 25% with an increasing number of spirals from the single- to the double-spiral cutting pattern for the hard rocks, whereas generally little effect was observed for the soft- and medium-strength rocks. The double-spiral cutting pattern appeared to be more effective than the single- or triple-spiral cutting pattern and had an advantage of lower side forces. The tool cutting speed had no apparent effect on the cutting performance. The estimation of the specific energy by the yield based on the theoretical swept area was not significantly different from that estimated by the yield based on the muck weighing, especially for the double- and triple-spiral cutting patterns and with the optimum ratio of line spacing to depth of cut per revolution. This study also demonstrated that the cutterhead and mechanical miner designs, semi-theoretical deterministic computer simulations and empirical performance predictions and optimization models should be based on realistic experimental simulations. Studies should be continued to obtain more reliable results by creating a larger database of laboratory tests and field performance records for mechanical miners using drag tools.
A Review on High-Speed Machining of Titanium Alloys
NASA Astrophysics Data System (ADS)
Rahman, Mustafizur; Wang, Zhi-Gang; Wong, Yoke-San
Titanium alloys have been widely used in the aerospace, biomedical and automotive industries because of their good strength-to-weight ratio and superior corrosion resistance. However, it is very difficult to machine them due to their poor machinability. When machining titanium alloys with conventional tools, the tool wear rate progresses rapidly, and it is generally difficult to achieve a cutting speed of over 60m/min. Other types of tool materials, including ceramic, diamond, and cubic boron nitride (CBN), are highly reactive with titanium alloys at higher temperature. However, binder-less CBN (BCBN) tools, which do not have any binder, sintering agent or catalyst, have a remarkably longer tool life than conventional CBN inserts even at high cutting speeds. In order to get deeper understanding of high speed machining (HSM) of titanium alloys, the generation of mathematical models is essential. The models are also needed to predict the machining parameters for HSM. This paper aims to give an overview of recent developments in machining and HSM of titanium alloys, geometrical modeling of HSM, and cutting force models for HSM of titanium alloys.
Small gravitationally elicited voltage transients in pea stems
NASA Technical Reports Server (NTRS)
Pickard, B. G.
1984-01-01
Decapitated veritcal stem segments were observed for 45 min, noting the number of transients mu V for each 5-min interval. Results for two sets of stem segments are plotted. The average frequencies were 0.72 + or -0.05 and 0.66 + or - 0.04 per 5 min. One set of segments was swiveled gently to the horizontal position; then, recording continued for another 90 min. Transients continued in the vertical controls at a closely similar average rate 0.78 + or - 0.04 per 5 min. However, after the first 5-min interval the horizontally placed plants exhibited transients at an increased average rate of 1.08 + or - 0.04 per 5 min. The frequency of transients also increased following horizontal placement of intact shoots. However, it appears that this increase had two components: one due to gravity reception, and one due to the redistribution of indolacetic acid (IAA) believed to mediate gravitropic curvature (or, more specifically, to the increase of IAA in the lower tissue.
Sogi, D S; Siddiq, M; Roidoung, S; Dolan, K D
2012-11-01
Mango (Mangifera indica L.) is a major tropical fruit that has not been exploited for fresh-cut or minimally processed products on a scale similar to apples, pineapples, or melons. The objective of this study was to investigate the effect of infrared (IR) treatment on total phenolics, carotenoids, ascorbic acid, and antioxidant properties of fresh-cut cubes from 'Tommy Atkin' mangoes. Mango cubes were IR treated (5, 10, 15 min) and evaluated at 4-d intervals during 16-d storage at 4 ± 1 °C. Total phenolics, carotenoids, and ascorbic acid content in fresh-cut control mango cubes were 43.33, 1.37, and 15.97 mg/100 g FW, respectively. IR treatments increased total phenolics (59.23 to 71.16 mg/100 g FW) and decreased ascorbic acid (12.14 to 15.38 mg/100 g, FW). Total carotenoids showed a mixed trend (1.13 to 1.66 mg/100 g, FW). The IR treatment showed a significant positive impact on antioxidant properties (μM TE/100 g, FW) of mango cubes, as assayed by ABTS (261.5 compared with 338.0 to 416.4), DPPH (270.5 compared with 289.4 to 360.5), and ORAC (6686 compared with 8450 to 12230). Total phenolics, carotenoids, ascorbic acid, and antioxidant capacity decreased over 16-d storage. However, IR treated samples had consistently higher ABTS, DPPH, and total phenolics during storage. It was demonstrated that IR treatment can be effectively used in improving antioxidant properties of fresh-cut mangoes with minimal effect on the visual appearance. Various methods/treatments are in use for extending the quality of fresh-cut fruits, including mild heat treatment. This study explored the application of infrared (IR) heat for processing fresh-cut mango cubes and evaluated its effect on vitamin C and antioxidant capacity during 16-d storage. This is the first study reporting on the use of IR heat in fresh-cut fruits. IR treatment was shown to be effective in retaining antioxidant properties of fresh-cut mango cubes with minimal effect on the visual appearance. © 2012 Institute of Food Technologists®
Simple to complex modeling of breathing volume using a motion sensor.
John, Dinesh; Staudenmayer, John; Freedson, Patty
2013-06-01
To compare simple and complex modeling techniques to estimate categories of low, medium, and high ventilation (VE) from ActiGraph™ activity counts. Vertical axis ActiGraph™ GT1M activity counts, oxygen consumption and VE were measured during treadmill walking and running, sports, household chores and labor-intensive employment activities. Categories of low (<19.3 l/min), medium (19.3 to 35.4 l/min) and high (>35.4 l/min) VEs were derived from activity intensity classifications (light <2.9 METs, moderate 3.0 to 5.9 METs and vigorous >6.0 METs). We examined the accuracy of two simple techniques (multiple regression and activity count cut-point analyses) and one complex (random forest technique) modeling technique in predicting VE from activity counts. Prediction accuracy of the complex random forest technique was marginally better than the simple multiple regression method. Both techniques accurately predicted VE categories almost 80% of the time. The multiple regression and random forest techniques were more accurate (85 to 88%) in predicting medium VE. Both techniques predicted the high VE (70 to 73%) with greater accuracy than low VE (57 to 60%). Actigraph™ cut-points for light, medium and high VEs were <1381, 1381 to 3660 and >3660 cpm. There were minor differences in prediction accuracy between the multiple regression and the random forest technique. This study provides methods to objectively estimate VE categories using activity monitors that can easily be deployed in the field. Objective estimates of VE should provide a better understanding of the dose-response relationship between internal exposure to pollutants and disease. Copyright © 2013 Elsevier B.V. All rights reserved.
Molecular dynamic simulation for nanometric cutting of single-crystal face-centered cubic metals.
Huang, Yanhua; Zong, Wenjun
2014-01-01
In this work, molecular dynamics simulations are performed to investigate the influence of material properties on the nanometric cutting of single crystal copper and aluminum with a diamond cutting tool. The atomic interactions in the two metallic materials are modeled by two sets of embedded atom method (EAM) potential parameters. Simulation results show that although the plastic deformation of the two materials is achieved by dislocation activities, the deformation behavior and related physical phenomena, such as the machining forces, machined surface quality, and chip morphology, are significantly different for different materials. Furthermore, the influence of material properties on the nanometric cutting has a strong dependence on the operating temperature.
A new IRT-based standard setting method: application to eCat-listening.
García, Pablo Eduardo; Abad, Francisco José; Olea, Julio; Aguado, David
2013-01-01
Criterion-referenced interpretations of tests are highly necessary, which usually involves the difficult task of establishing cut scores. Contrasting with other Item Response Theory (IRT)-based standard setting methods, a non-judgmental approach is proposed in this study, in which Item Characteristic Curve (ICC) transformations lead to the final cut scores. eCat-Listening, a computerized adaptive test for the evaluation of English Listening, was administered to 1,576 participants, and the proposed standard setting method was applied to classify them into the performance standards of the Common European Framework of Reference for Languages (CEFR). The results showed a classification closely related to relevant external measures of the English language domain, according to the CEFR. It is concluded that the proposed method is a practical and valid standard setting alternative for IRT-based tests interpretations.
Validity Issues in Standard-Setting Studies
ERIC Educational Resources Information Center
Pant, Hans A.; Rupp, Andre A.; Tiffin-Richards, Simon P.; Koller, Olaf
2009-01-01
Standard-setting procedures are a key component within many large-scale educational assessment systems. They are consensual approaches in which committees of experts set cut-scores on continuous proficiency scales, which facilitate communication of proficiency distributions of students to a wide variety of stakeholders. This communicative function…
Eisenhofer, Graeme; Lattke, Peter; Herberg, Maria; Siegert, Gabriele; Qin, Nan; Därr, Roland; Hoyer, Jana; Villringer, Arno; Prejbisz, Aleksander; Januszewicz, Andrzej; Remaley, Alan; Martucci, Victoria; Pacak, Karel; Ross, H Alec; Sweep, Fred C G J; Lenders, Jacques W M
2013-01-01
Measurements of plasma normetanephrine and metanephrine provide a useful diagnostic test for phaeochromocytoma, but this depends on appropriate reference intervals. Upper cut-offs set too high compromise diagnostic sensitivity, whereas set too low, false-positives are a problem. This study aimed to establish optimal reference intervals for plasma normetanephrine and metanephrine. Blood samples were collected in the supine position from 1226 subjects, aged 5-84 y, including 116 children, 575 normotensive and hypertensive adults and 535 patients in whom phaeochromocytoma was ruled out. Reference intervals were examined according to age and gender. Various models were examined to optimize upper cut-offs according to estimates of diagnostic sensitivity and specificity in a separate validation group of 3888 patients tested for phaeochromocytoma, including 558 with confirmed disease. Plasma metanephrine, but not normetanephrine, was higher (P < 0.001) in men than in women, but reference intervals did not differ. Age showed a positive relationship (P < 0.0001) with plasma normetanephrine and a weaker relationship (P = 0.021) with metanephrine. Upper cut-offs of reference intervals for normetanephrine increased from 0.47 nmol/L in children to 1.05 nmol/L in subjects over 60 y. A curvilinear model for age-adjusted compared with fixed upper cut-offs for normetanephrine, together with a higher cut-off for metanephrine (0.45 versus 0.32 nmol/L), resulted in a substantial gain in diagnostic specificity from 88.3% to 96.0% with minimal loss in diagnostic sensitivity from 93.9% to 93.6%. These data establish age-adjusted cut-offs of reference intervals for plasma normetanephrine and optimized cut-offs for metanephrine useful for minimizing false-positive results.
Eisenhofer, Graeme; Lattke, Peter; Herberg, Maria; Siegert, Gabriele; Qin, Nan; Därr, Roland; Hoyer, Jana; Villringer, Arno; Prejbisz, Aleksander; Januszewicz, Andrzej; Remaley, Alan; Martucci, Victoria; Pacak, Karel; Ross, H Alec; Sweep, Fred C G J; Lenders, Jacques W M
2016-01-01
Background Measurements of plasma normetanephrine and metanephrine provide a useful diagnostic test for phaeochromocytoma, but this depends on appropriate reference intervals. Upper cut-offs set too high compromise diagnostic sensitivity, whereas set too low, false-positives are a problem. This study aimed to establish optimal reference intervals for plasma normetanephrine and metanephrine. Methods Blood samples were collected in the supine position from 1226 subjects, aged 5–84 y, including 116 children, 575 normotensive and hypertensive adults and 535 patients in whom phaeochromocytoma was ruled out. Reference intervals were examined according to age and gender. Various models were examined to optimize upper cut-offs according to estimates of diagnostic sensitivity and specificity in a separate validation group of 3888 patients tested for phaeochromocytoma, including 558 with confirmed disease. Results Plasma metanephrine, but not normetanephrine, was higher (P < 0.001) in men than in women, but reference intervals did not differ. Age showed a positive relationship (P < 0.0001) with plasma normetanephrine and a weaker relationship (P = 0.021) with metanephrine. Upper cut-offs of reference intervals for normetanephrine increased from 0.47 nmol/L in children to 1.05 nmol/L in subjects over 60 y. A curvilinear model for age-adjusted compared with fixed upper cut-offs for normetanephrine, together with a higher cut-off for metanephrine (0.45 versus 0.32 nmol/L), resulted in a substantial gain in diagnostic specificity from 88.3% to 96.0% with minimal loss in diagnostic sensitivity from 93.9% to 93.6%. Conclusions These data establish age-adjusted cut-offs of reference intervals for plasma normetanephrine and optimized cut-offs for metanephrine useful for minimizing false-positive results. PMID:23065528
Study on the separation effect of high-speed ultrasonic vibration cutting.
Zhang, Xiangyu; Sui, He; Zhang, Deyuan; Jiang, Xinggang
2018-07-01
High-speed ultrasonic vibration cutting (HUVC) has been proven to be significantly effective when turning Ti-6Al-4V alloy in recent researches. Despite of breaking through the cutting speed restriction of the ultrasonic vibration cutting (UVC) method, HUVC can also achieve the reduction of cutting force and the improvements in surface quality and cutting efficiency in the high-speed machining field. These benefits all result from the separation effect that occurs during the HUVC process. Despite the fact that the influences of vibration and cutting parameters have been discussed in previous researches, the separation analysis of HUVC should be conducted in detail in real cutting situations, and the tool geometry parameters should also be considered. In this paper, three situations are investigated in details: (1) cutting without negative transient clearance angle and without tool wear, (2) cutting with negative transient clearance angle and without tool wear, and (3) cutting with tool wear. And then, complete separation state, partial separation state and continuous cutting state are deduced according to real cutting processes. All the analysis about the above situations demonstrate that the tool-workpiece separation will take place only if appropriate cutting parameters, vibration parameters, and tool geometry parameters are set up. The best separation effect was obtained with a low feedrate and a phase shift approaching 180 degrees. Moreover, flank face interference resulted from the negative transient clearance angle and tool wear contributes to an improved separation effect that makes the workpiece and tool separate even at zero phase shift. Finally, axial and radial transient cutting force are firstly obtained to verify the separation effect of HUVC, and the cutting chips are collected to weigh the influence of flank face interference. Copyright © 2018 Elsevier B.V. All rights reserved.
Construct Maps as a Foundation for Standard Setting
ERIC Educational Resources Information Center
Wyse, Adam E.
2013-01-01
Construct maps are tools that display how the underlying achievement construct upon which one is trying to set cut-scores is related to other information used in the process of standard setting. This article reviews what construct maps are, uses construct maps to provide a conceptual framework to view commonly used standard-setting procedures (the…
Chikata, Yusuke; Ohnishi, Saki; Nishimura, Masaji
2017-05-01
High-flow nasal cannula therapy (HFNC) for neonate/infants can deliver up to 10 L/min of heated and humidified gas, and F IO 2 can be adjusted to between 0.21 and 1.0. With adults, humidification and actual F IO 2 are known to vary according to inspiratory and HFNC gas flow, tidal volume (V T ), and ambient temperature. There have been few studies focused on humidification and F IO 2 in HFNC settings for neonates/infants, so we performed a bench study to investigate the influence of gas flow, ambient temperature, and respiratory parameters on humidification and actual F IO 2 in a neonate/infant simulation. HFNC gas flow was set at 3, 5, and 7 L/min, and F IO 2 was set at 0.3, 0.5, and 0.7. Spontaneous breathing was simulated using a 2-bellows-in-a-box model of a neonate lung. Tests were conducted with V T settings of 20, 30, and 40 mL and breathing frequencies of 20 and 30 breaths/min. Inspiratory time was 0.8 s with decelerating flow waveform. The HFNC tube was placed in an incubator, which was either set at 37°C or turned off. Absolute humidity (AH) and actual F IO 2 were measured for 1 min using a hygrometer and an oxygen analyzer, and data for the final 3 breaths were extracted. At all settings, when the incubator was turned on, AH was greater than when it was turned off ( P < .001). When the incubator was turned off, as gas flow increased, AH increased ( P < .001); however, V T did not affect AH ( P = .16). As gas flow increased, actual F IO 2 more closely corresponded to set F IO 2 . When gas flow was 3 L/min, measured F IO 2 decreased proportionally more at each F IO 2 setting increment ( P < .001). AH was affected by ambient temperature and HFNC gas flow. Actual F IO 2 depended on V T when gas flow was 3 L/min. Copyright © 2017 by Daedalus Enterprises.
Farooq, U; Malecki, I A; Mahmood, M; Martin, G B
2017-06-01
One of the basic steps in objective analysis of sperm motility is the subdivision of a motile sperm population into slow, medium and rapid categories based on their velocity. However, for CASA analysis of quail sperm, the velocity values for categorization of slow, medium and rapid sperm have not yet been standardized. To identify the cut-off values of "velocity curvilinear" (VCL) for quail sperm categorization, we captured and analysed 22,300 tracks of quail sperm using SCA ® -CASA. The median and mean VCL values were 85 and 97 μm/s. To define the VCL cut-off values, we used two methods. In the first, we identified the upper (rapid sperm) and lower (slow sperm) cut-off values using: (i) median VCL ± 25% or ± 50% or ± 75% of median VCL value; (ii) first and third quartile values of VCL data (i.e. 25% cut-off setting); and (iii) 33% and 66% of VCL data. Among these settings, sperm categories and their corresponding motility characteristics recorded using the "25%" setting (i.e. slow ≤36 ≤ medium ≤154 ≤ rapid) were found the most realistic and coherent with male ranking by fertility. In the second method, we calculated heteroscedasticity in the total VCL data using PCA and the two-step clustering method. With this approach, the mean of the high and low clusters was 165 and 51 μm/s, respectively. Together, the mean from two methods suggested that, for SCA ® -CASA categorization of quail sperm, sperm should be classed as "rapid" at VCL ≥160 μm/s and "slow" at VCL ≤45 μm/s. © 2017 Blackwell Verlag GmbH.
A Modified MinMax k-Means Algorithm Based on PSO.
Wang, Xiaoyan; Bai, Yanping
The MinMax k -means algorithm is widely used to tackle the effect of bad initialization by minimizing the maximum intraclustering errors. Two parameters, including the exponent parameter and memory parameter, are involved in the executive process. Since different parameters have different clustering errors, it is crucial to choose appropriate parameters. In the original algorithm, a practical framework is given. Such framework extends the MinMax k -means to automatically adapt the exponent parameter to the data set. It has been believed that if the maximum exponent parameter has been set, then the programme can reach the lowest intraclustering errors. However, our experiments show that this is not always correct. In this paper, we modified the MinMax k -means algorithm by PSO to determine the proper values of parameters which can subject the algorithm to attain the lowest clustering errors. The proposed clustering method is tested on some favorite data sets in several different initial situations and is compared to the k -means algorithm and the original MinMax k -means algorithm. The experimental results indicate that our proposed algorithm can reach the lowest clustering errors automatically.
House GOP Presses for Deep Cuts to Education
ERIC Educational Resources Information Center
Klein, Alyson
2011-01-01
Republicans in the U.S. House of Representatives appear determined to make deep cuts to education and related programs in the temporary spending bill that would keep the federal government operating for the rest of the fiscal year, even as President Barack Obama seeks a modest funding boost next year. That sets up a fiscal face-off in the…
Creating a standardized and simplified cutting bill using group technology
Urs Buehlmann; Janice K. Wiedenbeck; R., Jr. Noble; D. Earl Kline
2008-01-01
From an analytical viewpoint, the relationship between rough mill cutting bill part requirements and lumber yield is highly complex. Part requirements can have almost any length, width, and quantity distribution within the boundaries set by physical limitations, such as maximum length and width of parts. This complexity makes it difficult to understand the specific...
How fast to northern hardwoods grow?
Rapheal Zon; H.F. Scholz
1929-01-01
The knowledge of the rate at which trees grow in virgin forests, after clear cutting and under selective logging, is indispensable in any forest calculations or forest practice. The enactment of the Forest Crop Law, which brought under its operation about 175,000 acres of cut-over land during the first year, the example set by several progressive lumbermen in selective...
Reiner, Caecilia S; Gordic, Sonja; Puippe, Gilbert; Morsbach, Fabian; Wurnig, Moritz; Schaefer, Niklaus; Veit-Haibach, Patrick; Pfammatter, Thomas; Alkadhi, Hatem
2016-03-01
To evaluate in patients with hepatocellular carcinoma (HCC), whether assessment of tumor heterogeneity by histogram analysis of computed tomography (CT) perfusion helps predicting response to transarterial radioembolization (TARE). Sixteen patients (15 male; mean age 65 years; age range 47-80 years) with HCC underwent CT liver perfusion for treatment planning prior to TARE with Yttrium-90 microspheres. Arterial perfusion (AP) derived from CT perfusion was measured in the entire tumor volume, and heterogeneity was analyzed voxel-wise by histogram analysis. Response to TARE was evaluated on follow-up imaging (median follow-up, 129 days) based on modified Response Evaluation Criteria in Solid Tumors (mRECIST). Results of histogram analysis and mean AP values of the tumor were compared between responders and non-responders. Receiver operating characteristics were calculated to determine the parameters' ability to discriminate responders from non-responders. According to mRECIST, 8 patients (50%) were responders and 8 (50%) non-responders. Comparing responders and non-responders, the 50th and 75th percentile of AP derived from histogram analysis was significantly different [AP 43.8/54.3 vs. 27.6/34.3 mL min(-1) 100 mL(-1)); p < 0.05], while the mean AP of HCCs (43.5 vs. 27.9 mL min(-1) 100 mL(-1); p > 0.05) was not. Further heterogeneity parameters from histogram analysis (skewness, coefficient of variation, and 25th percentile) did not differ between responders and non-responders (p > 0.05). If the cut-off for the 75th percentile was set to an AP of 37.5 mL min(-1) 100 mL(-1), therapy response could be predicted with a sensitivity of 88% (7/8) and specificity of 75% (6/8). Voxel-wise histogram analysis of pretreatment CT perfusion indicating tumor heterogeneity of HCC improves the pretreatment prediction of response to TARE.
Banda, Jorge A; Haydel, K Farish; Davila, Tania; Desai, Manisha; Bryson, Susan; Haskell, William L; Matheson, Donna; Robinson, Thomas N
2016-01-01
To examine the effects of accelerometer epoch lengths, wear time (WT) algorithms, and activity cut-points on estimates of WT, sedentary behavior (SB), and physical activity (PA). 268 7-11 year-olds with BMI ≥ 85th percentile for age and sex wore accelerometers on their right hips for 4-7 days. Data were processed and analyzed at epoch lengths of 1-, 5-, 10-, 15-, 30-, and 60-seconds. For each epoch length, WT minutes/day was determined using three common WT algorithms, and minutes/day and percent time spent in SB, light (LPA), moderate (MPA), and vigorous (VPA) PA were determined using five common activity cut-points. ANOVA tested differences in WT, SB, LPA, MPA, VPA, and MVPA when using the different epoch lengths, WT algorithms, and activity cut-points. WT minutes/day varied significantly by epoch length when using the NHANES WT algorithm (p < .0001), but did not vary significantly by epoch length when using the ≥ 20 minute consecutive zero or Choi WT algorithms. Minutes/day and percent time spent in SB, LPA, MPA, VPA, and MVPA varied significantly by epoch length for all sets of activity cut-points tested with all three WT algorithms (all p < .0001). Across all epoch lengths, minutes/day and percent time spent in SB, LPA, MPA, VPA, and MVPA also varied significantly across all sets of activity cut-points with all three WT algorithms (all p < .0001). The common practice of converting WT algorithms and activity cut-point definitions to match different epoch lengths may introduce significant errors. Estimates of SB and PA from studies that process and analyze data using different epoch lengths, WT algorithms, and/or activity cut-points are not comparable, potentially leading to very different results, interpretations, and conclusions, misleading research and public policy.
NASA Astrophysics Data System (ADS)
Cheluszka, Piotr
2017-12-01
This article discusses the issue of selecting a pick system for cutting mining machinery, concerning the reduction of vibrations in the cutting system, particularly in a load-carrying structure at work. Numerical analysis was performed on a telescopic roadheader boom equipped with transverse heads. A frequency range of the boom's free vibrations with a set structure and dynamic properties were determined based on a dynamic model. The main components excited by boom vibrations, generated through the process of cutting rock, were identified. This was closely associated with the stereometry of the cutting heads. The impact on the pick system (the number of picks and their arrangement along the side of the cutting head) was determined by the intensity of the external boom load elements, especially in resonance zones. In terms of the anti-resonance criterion, an advantageous system of cutting head picks was determined as a result of the analysis undertaken. The correct selection of the pick system was ascertained based on a computer simulation of the dynamic loads and vibrations of a roadheader telescopic boom.
NASA Astrophysics Data System (ADS)
Zhang, P. P.; Guo, Y.; Wang, B.
2017-05-01
The main problems in milling difficult-to-machine materials are the high cutting temperature and rapid tool wear. However it is impossible to investigate tool wear in machining. Tool wear and cutting chip formation are two of the most important representations for machining efficiency and quality. The purpose of this paper is to develop the model of tool wear with cutting chip formation (width of chip and radian of chip) on difficult-to-machine materials. Thereby tool wear is monitored by cutting chip formation. A milling experiment on the machining centre with three sets cutting parameters was performed to obtain chip formation and tool wear. The experimental results show that tool wear increases gradually along with cutting process. In contrast, width of chip and radian of chip decrease. The model is developed by fitting the experimental data and formula transformations. The most of monitored errors of tool wear by the chip formation are less than 10%. The smallest error is 0.2%. Overall errors by the radian of chip are less than the ones by the width of chip. It is new way to monitor and detect tool wear by cutting chip formation in milling difficult-to-machine materials.
Panos, Marios Z; Koumi, Andriani
2014-05-01
The 40W-0.8 l/min setting is widely recommended for argon plasma coagulation (APC) in the right colon. Until March 2012, we used the 60W-1.2 l/min setting for all sites of the colon. By auditing our experience, we assessed the safety-risk profile of the 60W-1.2 l/min setting in the right and left colon. All cases treated with APC by a single endoscopist, using the 60W-1.2 l/min setting for all sites of the colon between October 2001 and December 2007 were identified retrospectively and site, type, number of lesions, and complications were recorded. Between January 2008 and March 2012, information was recorded prospectively. In the retrospective audit, 290 lesions (101 cecum/ascending, 120 sigmoid/descending, 69 transverse) were treated in 241 patient endoscopies. There were no perforations. In the prospective audit, 156 lesions (83 cecum/ascending, 47 sigmoid/descending, 26 transverse) were treated in 132 patient endoscopies. There was 1/83 (1.2%) perforation in the cecum/ascending colon and none in the transverse or sigmoid/descending (n.s.). Combined, the results yield a cecal/ascending perforation rate of 1/153 (0.6%) patient endoscopies, 1/184 (0.5%) lesions treated and overall perforation rate for all sites of the colon of 1/373 (0.3%) patient endoscopies and 1/446 (0.2%) lesions. Post-polypectomy syndrome and delayed bleeding each occurred in 3/373 (0.8%) patient endoscopies and 3/446 (0.7%) lesions. There were no deaths. In the cecum and ascending colon, the APC perforation rate at the 60W-1.2 l/min setting was no higher than in the left colon and is similar to that reported in previously published series. Therefore, it appears safe, provided the precautions we describe are strictly followed.
Implications for social policy of variability in racial groups.
Helms, Janet E
2008-11-01
Social policy and federal and state legislation require the use of single cut scores when tests of cognitive ability, knowledge, or skills (CAKS) are used to make high-stakes assessment decisions, such as whether students or employees may be promoted. Rationales offered for the requirement are that cut scores provide objective standards and are fairer than using subjective criteria, such as racial group membership. It is argued that failure to consider threats to statistical conclusion validity, such as differences in variability between groups, obscures the differential impact of using a common cut score as the basis for highstakes decisions. Analyses of 40 Black and White samples revealed that (a) Whites might be considerably advantaged and Blacks might be considerably disadvantaged by the same cut score and (b) depending on where the cut score is set, decisions based on ratios of numbers of Whites numbers of Blacks might be fairer than use of CAKS test cut scores. Implications for assessment practice and social policy are discussed.
Hogan, Barbara; Rasche, Christoph; von Reinersdorff, Andrea Braun
2012-06-01
The number of patients seeking treatment in emergency departments is rising, although many governments are seeking to reduce expenditure on health. Emergency departments must achieve more with the same resources or perform the same functions with fewer resources. Patients demand higher emergency clinical care quality, with low waiting times viewed as a key quality criterion by many patients. The objective of this study was to create an improved working system in emergency departments that cuts patient waiting times for first specialty physician contact. Techniques from industrial flow management were applied to the working process of an emergency department and the concept was named 'First View.' A total of 3269 patient contacts using the First View Concept during a treatment month showed statistical significance. Before introduction, a total 3230 patients in a comparative treatment month had a median waiting time before the first doctor contact of 47.6 min, a first quartile waiting time of 36.1 min, and a third quartile waiting time of 62.7 min. After introduction, 3269 patients had a median waiting time before first specialty physician contact of 11.2 min, a first quartile waiting time of 9.1 min, and a third quartile waiting time of 15.2 min. Industrial flow concepts can achieve significant improvements in emergency department workflows in countries in which sufficient numbers of specialty physicians are available. More attention to the organization of emergency department working processes is needed, especially involving lean management.
Christensen, A. Kent
1971-01-01
A simple method has been developed that allows frozen thin sections of fresh-frozen tissue to be cut on a virtually unmodified ultramicrotome kept at room temperature. A bowl-shaped Dewar flask with a knifeholder in its depths replaces the stage of the microtome; a bar extends down into the bowl from the microtome's cutting arm and bears the frozen tissue near its lower end. When the microtome is operated, the tissue passes a glass or diamond knife in the depths of the bowl as in normal cutting. The cutting temperature is maintained by flushing the bowl with cold nitrogen gas, and can be set anywhere from about -160°C up to about -30°C. The microtome is set for a cutting thickness of 540–1000 A. Sections are picked up from the dry knife edge, and are placed on membrane-coated grids, flattened with the polished end of a copper rod, and either dried in nitrogen gas or freeze-dried. Throughout the entire process the tissue is kept cold and does not come in contact with any solvent. The morphology seen in frozen thin sections of rat pancreas and liver generally resembles that in conventional preparations, although freezing damage and low contrast limit the detail that can be discerned. Among unusual findings is a frequent abundance of mitochondrial granules in material prepared by this method. PMID:4942776
Matsha, Tandi E.; Kengne, Andre-Pascal; Yako, Yandiswa Y.; Hon, Gloudina M.; Hassan, Mogamat S.; Erasmus, Rajiv T.
2013-01-01
Background The proposed waist-to-height ratio (WHtR) cut-off of 0.5 is less optimal for cardiometabolic risk screening in children in many settings. The purpose of this study was to determine the optimal WHtR for children from South Africa, and investigate variations by gender, ethnicity and residence in the achieved value. Methods Metabolic syndrome (MetS) components were measured in 1272 randomly selected learners, aged 10–16 years, comprising of 446 black Africans, 696 mixed-ancestry and 130 Caucasians. The Youden’s index and the closest-top-left (CTL) point approaches were used to derive WHtR cut-offs for diagnosing any two MetS components, excluding the waist circumference. Results The two approaches yielded similar cut-off in girls, 0.465 (sensitivity 50.0, specificity 69.5), but two different values in boys, 0.455 (42.9, 88.4) and 0.425 (60.3, 67.7) based on the Youden’s index and the CTL point, respectively. Furthermore, WHtR cut-off values derived differed substantially amongst the regions and ethnic groups investigated, whereby the highest cut-off was observed in semi-rural and white children, respectively, Youden’s index0.505 (31.6, 87.1) and CTL point 0.475 (44.4, 75.9). Conclusion The WHtR cut-off of 0.5 is less accurate for screening cardiovascular risk in South African children. The optimal value in this setting is likely gender and ethnicity-specific and sensitive to urbanization. PMID:23967160
Evaluation of the Kuper-Tuca SX36 snow plow cutting edges.
DOT National Transportation Integrated Search
2010-06-01
For the winter of 2009-2010, the MaineDOT experimented with three sets of the Kuper Tuca SX36 : plow blades. Two of these sets were used in the Region 4, Bangor maintenance facility and one set was : used in the Region 3, Turner facility. : Maine...
Wong, Adrian; Xiong, Yun-yun; Wang, Defeng; Lin, Shi; Chu, Winnie W C; Kwan, Pauline W K; Nyenhuis, David; Black, Sandra E; Wong, Ka Sing Lawrence; Mok, Vincent
2013-05-01
Vascular cognitive impairment (VCI) affects up to half of stroke survivors and predicts poor outcomes. Valid and reliable assessement for VCI is lacking, especially for the Chinese population. In 2005, the National Institute of Neurological Disorders and Stroke and Canadian Stroke Network (NINDS-CSN) Harmonisation workshop proposed a set of three neuropsychology protocols for VCI evaluation. This paper is to introduce the protocol design and to report the psychometric properties of the Chinese NINDS-CSN VCI protocols. Fifty patients with mild stroke (mean National Institute of Health Stroke Scale 2.2 (SD=3.2)) and 50 controls were recruited. The NINDS-CSN VCI protocols were adapted into Chinese. We assessed protocols' (1) external validity, defined by how well the protocol summary scores differentiated patients from controls using receiver operating characteristics (ROC) curve analysis; (2) concurrent validity, by correlations with functional measures including Stroke Impact Scale memory score and Chinese Disability Assessment for Dementia; (3) internal consistency; and (4) ease of administration. All three protocols differentiated patients from controls (area under ROC for the three protocols between 0.77 to 0.79, p<0.001), and significantly correlated with the functional measures (Pearson r ranged from 0.37 to 0.51). A cut-off of 19/20 on MMSE identified only one-tenth of patients classified as impaired on the 5-min protocol. Cronbach's α across the four cognitive domains of the 60-min protocol was 0.78 for all subjects and 0.76 for stroke patients. The Chinese NINDS-CSN VCI protocols are valid and reliable for cognitive assessment in Chinese patients with mild stroke.
Life under the Spending Caps: The Clinton Fiscal Year 1995 Budget.
ERIC Educational Resources Information Center
Leonard, Paul; Greenstein, Robert
The stage for the introduction of the Clinton Administration's fiscal year 1995 budget was largely set by the passage of the budget reconciliation bill signed into law in August 1993. In developing the budget, the Administration had to come up with enough spending cuts to meet the spending caps--as well as billions of dollars in additional cuts to…
Reproduction following small group cuttings in virgin Douglas-fir.
Norman P. Worthington
1953-01-01
Quick and adequate regeneration of Douglas-fir forests as they are harvested is a major forest management problem in the Puget Sound region. Clear-cutting by staggered settings has not always resulted in adequate regeneration even where no part of the area is more than one-fourth mile from a seed source. Single tree selection, experimented with extensively, has many...
A Guide for Setting the Cut-Scores to Minimize Weighted Classification Errors in Test Batteries
ERIC Educational Resources Information Center
Grabovsky, Irina; Wainer, Howard
2017-01-01
In this article, we extend the methodology of the Cut-Score Operating Function that we introduced previously and apply it to a testing scenario with multiple independent components and different testing policies. We derive analytically the overall classification error rate for a test battery under the policy when several retakes are allowed for…
Orthodontic instrument sterilization with microwave irradiation.
Yezdani, Arif; Mahalakshmi, Krishnan; Padmavathy, Kesavaram
2015-04-01
This study was designed to evaluate the efficiency of microwave sterilization of orthodontic instruments and molar bands immersed in plain distilled water with and without oral rinse, and to ascertain the minimum time of exposure required to sterilize. The orthodontic instruments (hinged and nonhinged), molar bands and mouth mirrorsused in the patient 's mouth were selected for the study. The instruments were divided into two groups - Group I with oral rinse-set A (0.01% chlorhexidine gluconate) and set B (0.025% betadine) and Group II (included sets C and D without oral rinse). The instruments of set A, B and C were microwaved at 2,450 MHz, 800 W for 5 min, whereas, set D was microwaved for 10 min at the same above mentioned specifications. The efficacy of sterilization was assessed by stab inoculation of the instruments onto trypticase soya agar plates. The plates were checked for bacterial growth following incubation at 37 °C for 24 h. For sterility control,Geobacillus stearothermophilus (MTCC 1518) was included. No growth was observed in the plates that were inoculated with the microwaved orthodontic instruments of sets A, B and D, whereas scanty bacterial growth was observed in the plates inoculatedwith the microwaved set C instruments. Effective sterilization was achieved when the orthodontic instruments and molar bands were immersed in distilled water without oral rinse and microwaved for 10 min as also for those that were immersed in distilled water with oral rinse and microwaved for 5 min.
Orthodontic instrument sterilization with microwave irradiation
Yezdani, Arif; Mahalakshmi, Krishnan; Padmavathy, Kesavaram
2015-01-01
Objective: This study was designed to evaluate the efficiency of microwave sterilization of orthodontic instruments and molar bands immersed in plain distilled water with and without oral rinse, and to ascertain the minimum time of exposure required to sterilize. Materials and Methods: The orthodontic instruments (hinged and nonhinged), molar bands and mouth mirrorsused in the patient 's mouth were selected for the study. The instruments were divided into two groups – Group I with oral rinse-set A (0.01% chlorhexidine gluconate) and set B (0.025% betadine) and Group II (included sets C and D without oral rinse). The instruments of set A, B and C were microwaved at 2,450 MHz, 800 W for 5 min, whereas, set D was microwaved for 10 min at the same above mentioned specifications. The efficacy of sterilization was assessed by stab inoculation of the instruments onto trypticase soya agar plates. The plates were checked for bacterial growth following incubation at 37 °C for 24 h. For sterility control,Geobacillus stearothermophilus (MTCC 1518) was included. Results: No growth was observed in the plates that were inoculated with the microwaved orthodontic instruments of sets A, B and D, whereas scanty bacterial growth was observed in the plates inoculatedwith the microwaved set C instruments. Conclusion: Effective sterilization was achieved when the orthodontic instruments and molar bands were immersed in distilled water without oral rinse and microwaved for 10 min as also for those that were immersed in distilled water with oral rinse and microwaved for 5 min. PMID:26015686
Generation of segmental chips in metal cutting modeled with the PFEM
NASA Astrophysics Data System (ADS)
Rodriguez Prieto, J. M.; Carbonell, J. M.; Cante, J. C.; Oliver, J.; Jonsén, P.
2018-06-01
The Particle Finite Element Method, a lagrangian finite element method based on a continuous Delaunay re-triangulation of the domain, is used to study machining of Ti6Al4V. In this work the method is revised and applied to study the influence of the cutting speed on the cutting force and the chip formation process. A parametric methodology for the detection and treatment of the rigid tool contact is presented. The adaptive insertion and removal of particles are developed and employed in order to sidestep the difficulties associated with mesh distortion, shear localization as well as for resolving the fine-scale features of the solution. The performance of PFEM is studied with a set of different two-dimensional orthogonal cutting tests. It is shown that, despite its Lagrangian nature, the proposed combined finite element-particle method is well suited for large deformation metal cutting problems with continuous chip and serrated chip formation.
Generation of segmental chips in metal cutting modeled with the PFEM
NASA Astrophysics Data System (ADS)
Rodriguez Prieto, J. M.; Carbonell, J. M.; Cante, J. C.; Oliver, J.; Jonsén, P.
2017-09-01
The Particle Finite Element Method, a lagrangian finite element method based on a continuous Delaunay re-triangulation of the domain, is used to study machining of Ti6Al4V. In this work the method is revised and applied to study the influence of the cutting speed on the cutting force and the chip formation process. A parametric methodology for the detection and treatment of the rigid tool contact is presented. The adaptive insertion and removal of particles are developed and employed in order to sidestep the difficulties associated with mesh distortion, shear localization as well as for resolving the fine-scale features of the solution. The performance of PFEM is studied with a set of different two-dimensional orthogonal cutting tests. It is shown that, despite its Lagrangian nature, the proposed combined finite element-particle method is well suited for large deformation metal cutting problems with continuous chip and serrated chip formation.
Material Behavior At The Extreme Cutting Edge In Bandsawing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sarwar, Mohammed; Haider, Julfikar; Persson, Martin
2011-01-17
In recent years, bandsawing has been widely accepted as a favourite option for metal cutting off operations where the accuracy of cut, good surface finish, low kerf loss, long tool life and high material removal rate are required. Material removal by multipoint cutting tools such as bandsaw is a complex mechanism owing to the geometry of the bandsaw tooth (e.g., limited gullet size, tooth setting etc.) and the layer of material removed or undeformed chip thickness or depth of cut (5 {mu}m-50 {mu}m) being smaller than or equal to the cutting edge radius (5 {mu}m-15 {mu}m). This situation can leadmore » to inefficient material removal in bandsawing. Most of the research work are concentrated on the mechanics of material removal by single point cutting tool such as lathe tool. However, such efforts are very limited in multipoint cutting tools such as in bandsaw. This paper presents the fundamental understanding of the material behaviour at the extreme cutting edge of bandsaw tooth, which would help in designing and manufacturing of blades with higher cutting performance and life. ''High Speed Photography'' has been carried out to analyse the material removal process at the extreme cutting edge of bandsaw tooth. Geometric model of chip formation mechanisms based on the evidences found during ''High Speed Photography'' and ''Quick Stop'' process is presented. Wear modes and mechanism in bimetal and carbide tipped bandsaw teeth are also presented.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flint, D B; O’Brien, D J; McFadden, C H
Purpose: To determine the effect of gold-nanoparticles (AuNPs) on energy deposition in water for different irradiation conditions. Methods: TOPAS version B12 Monte Carlo code was used to simulate energy deposition in water from monoenergetic 40 keV and 85 keV photon beams and a 6 MV Varian Clinac photon beam (IAEA phase space file, 10x10 cm{sup 2}, SSD 100 cm). For the 40 and 85 keV beams, monoenergetic 2x2 mm{sup 2} parallel beams were used to irradiate a 30x30x10 µm {sup 3} water mini-phantom located at 1.5 cm depth in a 30x30x50 cm{sup 3} water phantom. 5000 AuNPs of 50 nmmore » diameter were randomly distributed inside the mini-phantom. Energy deposition was scored in the mini-phantom with the AuNPs’ material set to gold and then water. For the 6 MV beam, we created another phase space (PHSP) file on the surface of a 2 mm diameter sphere located at 1.5 cm depth in the water phantom. The PHSP file consisted of all particles entering the sphere including backscattered particles. Simulations were then performed using the new PHSP as the source with the mini-phantom centered in a 2 mm diameter water sphere in vacuum. The g4em-livermore reference list was used with “EMRangeMin/EMRangeMax = 100 eV/7 MeV” and “SetProductionCutLowerEdge = 990 eV” to create the new PHSP, and “SetProductionCutLowerEdge = 100 eV” for the mini-phantom simulations. All other parameters were set as defaults (“finalRange = 100 µm”). Results: The addition of AuNPs resulted in an increase in the mini-phantom energy deposition of (7.5 ± 8.7)%, (1.6 ± 8.2)%, and (−0.6 ± 1.1)% for 40 keV, 85 keV and 6 MV beams respectively. Conclusion: Enhanced energy deposition was seen at low photon energies, but decreased with increasing energy. No enhancement was observed for the 6 MV beam. Future work is required to decrease the statistical uncertainties in the simulations. This research is partially supported from institutional funds from the Center for Radiation Oncology Research, The University of Texas MD Anderson Cancer Center.« less
1992-02-01
If abrasive cutting equipment is not available or coolant contamination is a concern, hand operated toothed blades or saws such as hack or coping saws...325 F) CE-345 7781 387 9.0 (15 PSI/250 F) CE-aSS 7781 35.1 8.1 (15 PS1/250 F) CE-339 120 A9.4 19.3 (15 PS4 /250 F) CE-324 7781 37 * 3 10.__5 I10 MIN/15
Validation of a portable nitric oxide analyzer for screening in primary ciliary dyskinesias.
Harris, Amanda; Bhullar, Esther; Gove, Kerry; Joslin, Rhiannon; Pelling, Jennifer; Evans, Hazel J; Walker, Woolf T; Lucas, Jane S
2014-02-10
Nasal nitric oxide (nNO) levels are very low in primary ciliary dyskinesia (PCD) and it is used as a screening test. We assessed the reliability and usability of a hand-held analyser in comparison to a stationary nitric oxide (NO) analyser in 50 participants (15 healthy, 13 PCD, 22 other respiratory diseases; age 6-79 years). Nasal NO was measured using a stationary NO analyser during a breath-holding maneuver, and using a hand-held analyser during tidal breathing, sampling at 2 ml/sec or 5 ml/sec. The three methods were compared for their specificity and sensitivity as a screen for PCD, their success rate in different age groups, within subject repeatability and acceptability. Correlation between methods was assessed. Valid nNO measurements were obtained in 94% of participants using the stationary analyser, 96% using the hand-held analyser at 5 ml/sec and 76% at 2 ml/sec. The hand-held device at 5 ml/sec had excellent sensitivity and specificity as a screening test for PCD during tidal breathing (cut-off of 30 nL/min,100% sensitivity, >95% specificity). The cut-off using the stationary analyser during breath-hold was 38 nL/min (100% sensitivity, 95% specificity). The stationary and hand-held analyser (5 ml/sec) showed reasonable within-subject repeatability(% coefficient of variation = 15). The hand-held NO analyser provides a promising screening tool for PCD.
Sanchez-Glanville, Carlos; Brindle, Mary E; Spence, Tanya; Blackwood, Jaime; Drews, Tanya; Menzies, Steve; Lopushinsky, Steven R
2015-05-01
Extracorporeal life support (ECLS) is a life-saving technology for the critically ill child. Our objective was to evaluate the outcomes of an educational curriculum designed to introduce an ECLS program to a noncardiac pediatric surgical center. An interdisciplinary curriculum was developed consisting of didactic courses, animal labs, simulations, and debrief sessions. We reviewed all patients requiring ECLS between October 2011 and December 2013. All health care practitioners involved in the ECLS training curriculum were surveyed to evaluate their perception of the educational program. Primary outcomes include successful cannulation and 30-day survival. The knowledge and confidence improved with statistical significance (p<0.0001-0.0003) for all of the components of the training curriculum. The highest score was given to the simulations. Twenty-one patients underwent cannulation. All patients were successfully cannulated to bypass, including six (28.6%) ECPR. Median time from activation to cutting was 52min (IQR 40-72), and from cutting to bypass 40min (IQR 30-45). Sixteen patients (76.2%) were decannulated to a sustainable cardiac rhythm and survived 30-days. An ECLS curriculum incorporating simulation and dedicated practice seems to have eliminated the potential learning curve associated with the introduction of a complex technology to a novice environment. Copyright © 2015 Elsevier Inc. All rights reserved.
Cross-Study Homogeneity of Psoriasis Gene Expression in Skin across a Large Expression Range
Kerkof, Keith; Timour, Martin; Russell, Christopher B.
2013-01-01
Background In psoriasis, only limited overlap between sets of genes identified as differentially expressed (psoriatic lesional vs. psoriatic non-lesional) was found using statistical and fold-change cut-offs. To provide a framework for utilizing prior psoriasis data sets we sought to understand the consistency of those sets. Methodology/Principal Findings Microarray expression profiling and qRT-PCR were used to characterize gene expression in PP and PN skin from psoriasis patients. cDNA (three new data sets) and cRNA hybridization (four existing data sets) data were compared using a common analysis pipeline. Agreement between data sets was assessed using varying qualitative and quantitative cut-offs to generate a DEG list in a source data set and then using other data sets to validate the list. Concordance increased from 67% across all probe sets to over 99% across more than 10,000 probe sets when statistical filters were employed. The fold-change behavior of individual genes tended to be consistent across the multiple data sets. We found that genes with <2-fold change values were quantitatively reproducible between pairs of data-sets. In a subset of transcripts with a role in inflammation changes detected by microarray were confirmed by qRT-PCR with high concordance. For transcripts with both PN and PP levels within the microarray dynamic range, microarray and qRT-PCR were quantitatively reproducible, including minimal fold-changes in IL13, TNFSF11, and TNFRSF11B and genes with >10-fold changes in either direction such as CHRM3, IL12B and IFNG. Conclusions/Significance Gene expression changes in psoriatic lesions were consistent across different studies, despite differences in patient selection, sample handling, and microarray platforms but between-study comparisons showed stronger agreement within than between platforms. We could use cut-offs as low as log10(ratio) = 0.1 (fold-change = 1.26), generating larger gene lists that validate on independent data sets. The reproducibility of PP signatures across data sets suggests that different sample sets can be productively compared. PMID:23308107
Ono, Y.; Woodmass, J. M.; Nelson, A. A.; Boorman, R. S.; Thornton, G. M.
2016-01-01
Objectives This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P). Methods Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cadaveric bone and foam blocks representing normal to osteopenic bone. Mechanical testing included preloading to 10 N and cyclic loading for 500 cycles from 10 N to 60 N at 60 mm/min. The parameters evaluated were initial displacement, cyclic displacement and number of cycles and load at 3 mm displacement relative to preload. Video recording throughout testing documented the predominant source of suture displacement and the distance of ‘suture cutting through bone’. Results In cadaveric bone and foam blocks, MultiFIX P anchors had significantly greater initial displacement, and lower number of cycles and lower load at 3 mm displacement than SpeedScrew anchors. Video analysis revealed ‘suture cutting through bone’ as the predominant source of suture displacement in cadaveric bone (qualitative) and greater ‘suture cutting through bone’ comparing MultiFIX P with SpeedScrew anchors in foam blocks (quantitative). The greater suture displacement in MultiFIX P anchors was predominantly from suture cutting through bone, which was enhanced in an osteopenic bone model. Conclusions Anchors with sutures external to the anchor body are at risk for suture cutting through bone since the suture eyelet is at the distal tip of the implant and the suture directly abrades against the bone edge during cyclic loading. Suture cutting through bone may be a significant source of fixation failure, particularly in osteopenic bone. Cite this article: Y. Ono, J. M. Woodmass, A. A. Nelson, R. S. Boorman, G. M. Thornton, I. K. Y. Lo. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone. Bone Joint Res 2016;5:269–275. DOI: 10.1302/2046-3758.56.2000535. PMID:27357383
Ono, Y; Woodmass, J M; Nelson, A A; Boorman, R S; Thornton, G M; Lo, I K Y
2016-06-01
This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P). Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cadaveric bone and foam blocks representing normal to osteopenic bone. Mechanical testing included preloading to 10 N and cyclic loading for 500 cycles from 10 N to 60 N at 60 mm/min. The parameters evaluated were initial displacement, cyclic displacement and number of cycles and load at 3 mm displacement relative to preload. Video recording throughout testing documented the predominant source of suture displacement and the distance of 'suture cutting through bone'. In cadaveric bone and foam blocks, MultiFIX P anchors had significantly greater initial displacement, and lower number of cycles and lower load at 3 mm displacement than SpeedScrew anchors. Video analysis revealed 'suture cutting through bone' as the predominant source of suture displacement in cadaveric bone (qualitative) and greater 'suture cutting through bone' comparing MultiFIX P with SpeedScrew anchors in foam blocks (quantitative). The greater suture displacement in MultiFIX P anchors was predominantly from suture cutting through bone, which was enhanced in an osteopenic bone model. Anchors with sutures external to the anchor body are at risk for suture cutting through bone since the suture eyelet is at the distal tip of the implant and the suture directly abrades against the bone edge during cyclic loading. Suture cutting through bone may be a significant source of fixation failure, particularly in osteopenic bone.Cite this article: Y. Ono, J. M. Woodmass, A. A. Nelson, R. S. Boorman, G. M. Thornton, I. K. Y. Lo. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone. Bone Joint Res 2016;5:269-275. DOI: 10.1302/2046-3758.56.2000535. © 2016 Lo et al.
Empirical study of classification process for two-stage turbo air classifier in series
NASA Astrophysics Data System (ADS)
Yu, Yuan; Liu, Jiaxiang; Li, Gang
2013-05-01
The suitable process parameters for a two-stage turbo air classifier are important for obtaining the ultrafine powder that has a narrow particle-size distribution, however little has been published internationally on the classification process for the two-stage turbo air classifier in series. The influence of the process parameters of a two-stage turbo air classifier in series on classification performance is empirically studied by using aluminum oxide powders as the experimental material. The experimental results show the following: 1) When the rotor cage rotary speed of the first-stage classifier is increased from 2 300 r/min to 2 500 r/min with a constant rotor cage rotary speed of the second-stage classifier, classification precision is increased from 0.64 to 0.67. However, in this case, the final ultrafine powder yield is decreased from 79% to 74%, which means the classification precision and the final ultrafine powder yield can be regulated through adjusting the rotor cage rotary speed of the first-stage classifier. 2) When the rotor cage rotary speed of the second-stage classifier is increased from 2 500 r/min to 3 100 r/min with a constant rotor cage rotary speed of the first-stage classifier, the cut size is decreased from 13.16 μm to 8.76 μm, which means the cut size of the ultrafine powder can be regulated through adjusting the rotor cage rotary speed of the second-stage classifier. 3) When the feeding speed is increased from 35 kg/h to 50 kg/h, the "fish-hook" effect is strengthened, which makes the ultrafine powder yield decrease. 4) To weaken the "fish-hook" effect, the equalization of the two-stage wind speeds or the combination of a high first-stage wind speed with a low second-stage wind speed should be selected. This empirical study provides a criterion of process parameter configurations for a two-stage or multi-stage classifier in series, which offers a theoretical basis for practical production.
Heart failure severity, inappropriate ICD therapy, and novel ICD programming: a MADIT-RIT substudy.
Daimee, Usama A; Vermilye, Katherine; Rosero, Spencer; Schuger, Claudio D; Daubert, James P; Zareba, Wojciech; McNitt, Scott; Polonsky, Bronislava; Moss, Arthur J; Kutyifa, Valentina
2017-12-01
The effects of heart failure (HF) severity on risk of inappropriate implantable cardioverter-defibrillator (ICD) therapy have not been thoroughly investigated. We aimed to study the association between HF severity and inappropriate ICD therapy in MADIT-RIT. MADIT-RIT randomized 1,500 patients to three ICD programming arms: conventional (Arm A), high-rate cut-off (Arm B: ≥200 beats/min), and delayed therapy (Arm C: 60-second delay for ≥170 beats/min). We evaluated the association between New York Heart Association (NYHA) class III (n = 256) versus class I-II (n = 251) and inappropriate ICD therapy in Arm A patients with ICD-only and cardiac resynchronization therapy with defibrillator (CRT-D). We additionally assessed benefit of novel ICD programming in Arms B and C versus Arm A by NYHA classification. In Arm A, the risk of inappropriate therapy was significantly higher in those with NYHA III versus NYHA I-II for both ICD (hazard ratio [HR] = 2.55, confidence interval [CI]: 1.51-4.30, P < 0.001) and CRT-D patients (HR = 3.73, CI: 1.14-12.23, P = 0.030). This was consistent for inappropriate ATP and inappropriate ICD therapy < 200 beats/min, but not for inappropriate shocks. Novel ICD programming significantly reduced inappropriate therapy in patients with both NYHA III (Arm B vs Arm A: HR = 0.08, P < 0.001; Arm C vs Arm A: HR = 0.17, P < 0.001) and NYHA I-II (Arm B vs Arm A: HR = 0.25, P < 0.001; Arm C vs Arm A: HR = 0.28, P < 0.001). Patients with more severe HF are at increased risk for inappropriate ICD therapy, particularly ATP due to arrhythmias < 200 beats/min. Novel programming with high-rate cut-off or delayed detection reduces inappropriate ICD therapies in both mild and moderate HF. © 2017 Wiley Periodicals, Inc.
Application of dynamic milling in stainless steel processing
NASA Astrophysics Data System (ADS)
Shan, Wenju
2017-09-01
This paper mainly introduces the method of parameter setting for NC programming of stainless steel parts by dynamic milling. Stainless steel is of high plasticity and toughness, serious hard working, large cutting force, high temperature in cutting area and easy wear of tool. It is difficult to process material. Dynamic motion technology is the newest NC programming technology of Mastercam software. It is an advanced machining idea. The tool path generated by the dynamic motion technology is more smooth, more efficient and more stable in the machining process. Dynamic motion technology is very suitable for cutting hard machining materials.
Acute Effect of Interval Walking on Arterial Stiffness in Healthy Young Adults.
Okamoto, Takanobu; Min, Seok-Ki; Sakamaki-Sunaga, Mikako
2018-05-18
The purpose of this study was to determine the acute effects of interval walking (IW) on arterial stiffness. The participants in this study were 14 healthy men and women (age 27.5±3.8 y). Carotid-femoral pulse wave velocity (cfPWV) was measured using an automatic oscillometric device at 30 min before (baseline) and at 30 and 60 min after walking. Participants repeated five sets of 3-min walks at 30% and 70% of maximum aerobic capacity for a total of 6 min per set in the IW trial. The participants also walked for 30 min at 50% (moderate intensity) of maximum aerobic capacity in a continuous walking (CW) trial. cfPWV was significantly decreased from baseline at 30 min (P=0.02) after the IW trial, and this reduction in cfPWV persisted for 60 min (P=0.01). In contrast, cfPWV was significantly decreased from baseline at 30 min (P=0.03) after the CW trial, but the reduction did not persist for 60 min. Moreover, changes in cfPWV in the IW trial after 30 and 60 min were significantly lower than in the CW trial (P<0.05). These results suggest that IW acutely reduces central arterial stiffness more than CW in healthy young adults. © Georg Thieme Verlag KG Stuttgart · New York.
Maruthi, Midatharahally N; Jeremiah, Simon C; Mohammed, Ibrahim U; Legg, James P
2017-12-01
Cassava brown streak disease (CBSD) is arguably the most dangerous current threat to cassava, which is Africa's most important food security crop. CBSD is caused by two RNA viruses: Cassava brown streak virus (CBSV) and Ugandan cassava brown streak virus (UCBSV). The roles of the whitefly Bemisia tabaci (Gennadius) and farmer practices in the spread of CBSD were investigated in a set of field and laboratory experiments. The virus was acquired and transmitted by B. tabaci within a short time (5-10 min each for virus acquisition and inoculation), and was retained for up to 48 hr. Highest virus transmission (60%) was achieved using 20-25 suspected viruliferous whiteflies per plant that were given acquisition and inoculation periods of 24 and 48 hr, respectively. Experiments mimicking the agronomic practices of cassava leaf picking or the use of contaminated tools for making cassava stem cuttings did not show the transmission of CBSV or UCBSV. Screenhouse and field experiments in Tanzania showed that the spread of CBSD next to spreader rows was high, and that the rate of spread decreased with increasing distance from the source of inoculum. The disease spread in the field up to a maximum of 17 m in a cropping season. These results collectively confirm that CBSV and UCBSV are transmitted by B. tabaci semipersistently, but for only short distances in the field. This implies that spread over longer distances is due to movements of infected stem cuttings used for planting material. These findings have important implications for developing appropriate management strategies for CBSD.
Differences in sampling techniques on total post-mortem tryptase.
Tse, R; Garland, J; Kesha, K; Elstub, H; Cala, A D; Ahn, Y; Stables, S; Palmiere, C
2018-05-01
The measurement of mast cell tryptase is commonly used to support the diagnosis of anaphylaxis. In the post-mortem setting, the literature recommends sampling from peripheral blood sources (femoral blood) but does not specify the exact sampling technique. Sampling techniques vary between pathologists, and it is unclear whether different sampling techniques have any impact on post-mortem tryptase levels. The aim of this study is to compare the difference in femoral total post-mortem tryptase levels between two sampling techniques. A 6-month retrospective study comparing femoral total post-mortem tryptase levels between (1) aspirating femoral vessels with a needle and syringe prior to evisceration and (2) femoral vein cut down during evisceration. Twenty cases were identified, with three cases excluded from analysis. There was a statistically significant difference (paired t test, p < 0.05) between mean post-mortem tryptase by aspiration (10.87 ug/L) and by cut down (14.15 ug/L). The mean difference between the two methods was 3.28 ug/L (median, 1.4 ug/L; min, - 6.1 ug/L; max, 16.5 ug/L; 95% CI, 0.001-6.564 ug/L). Femoral total post-mortem tryptase is significantly different, albeit by a small amount, between the two sampling methods. The clinical significance of this finding and what factors may contribute to it are unclear. When requesting post-mortem tryptase, the pathologist should consider documenting the exact blood collection site and method used for collection. In addition, blood samples acquired by different techniques should not be mixed together and should be analyzed separately if possible.
A Modified MinMax k-Means Algorithm Based on PSO
2016-01-01
The MinMax k-means algorithm is widely used to tackle the effect of bad initialization by minimizing the maximum intraclustering errors. Two parameters, including the exponent parameter and memory parameter, are involved in the executive process. Since different parameters have different clustering errors, it is crucial to choose appropriate parameters. In the original algorithm, a practical framework is given. Such framework extends the MinMax k-means to automatically adapt the exponent parameter to the data set. It has been believed that if the maximum exponent parameter has been set, then the programme can reach the lowest intraclustering errors. However, our experiments show that this is not always correct. In this paper, we modified the MinMax k-means algorithm by PSO to determine the proper values of parameters which can subject the algorithm to attain the lowest clustering errors. The proposed clustering method is tested on some favorite data sets in several different initial situations and is compared to the k-means algorithm and the original MinMax k-means algorithm. The experimental results indicate that our proposed algorithm can reach the lowest clustering errors automatically. PMID:27656201
Geminiani, Alessandro; Abdel-Azim, Tamer; Ercoli, Carlo; Feng, Changyong; Meirelles, Luiz; Massironi, Domenico
2014-07-01
Rotary and nonrotary cutting instruments are used to produce specific characteristics on the axial and marginal surfaces of teeth being prepared for fixed restorations. Oscillating instruments have been suggested for tooth preparation, but no comparative surface roughness data are available. To compare the surface roughness of simulated tooth preparations produced by oscillating instruments versus rotary cutting instruments with turbine and electric handpieces. Different grit rotary cutting instruments were used to prepare Macor specimens (n=36) with 2 handpieces. The surface roughness obtained with rotary cutting instruments was compared with that produced by oscillating cutting instruments. The instruments used were as follows: coarse, then fine-grit rotary cutting instruments with a turbine (group CFT) or an electric handpiece (group CFE); coarse, then medium-grit rotary cutting instruments with a turbine (group CMT) or an electric handpiece (group CME); coarse-grit rotary cutting instruments with a turbine handpiece and oscillating instruments at a low-power (group CSL) or high-power setting (group CSH). A custom testing apparatus was used to test all instruments. The average roughness was measured for each specimen with a 3-dimensional optical surface profiler and compared with 1-way ANOVA and the Tukey honestly significant difference post hoc test for multiple comparisons (α=.05). Oscillating cutting instruments produced surface roughness values similar to those produced by similar grit rotary cutting instruments with a turbine handpiece. The electric handpiece produced smoother surfaces than the turbine regardless of rotary cutting instrument grit. Rotary cutting instruments with electric handpieces produced the smoothest surface, whereas the same instruments used with a turbine and oscillating instruments achieved similar surface roughness. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Shi, Zhenyu; Liu, Zhanqiang; Li, Yuchao; Qiao, Yang
2017-01-01
Cutting tool geometry should be very much considered in micro-cutting because it has a significant effect on the topography and accuracy of the machined surface, particularly considering the uncut chip thickness is comparable to the cutting edge radius. The objective of this paper was to clarify the influence of the mechanism of the cutting tool geometry on the surface topography in the micro-milling process. Four different cutting tools including two two-fluted end milling tools with different helix angles of 15° and 30° cutting tools, as well as two three-fluted end milling tools with different helix angles of 15° and 30° were investigated by combining theoretical modeling analysis with experimental research. The tool geometry was mathematically modeled through coordinate translation and transformation to make all three cutting edges at the cutting tool tip into the same coordinate system. Swept mechanisms, minimum uncut chip thickness, and cutting tool run-out were considered on modeling surface roughness parameters (the height of surface roughness Rz and average surface roughness Ra) based on the established mathematical model. A set of cutting experiments was carried out using four different shaped cutting tools. It was found that the sweeping volume of the cutting tool increases with the decrease of both the cutting tool helix angle and the flute number. Great coarse machined surface roughness and more non-uniform surface topography are generated when the sweeping volume increases. The outcome of this research should bring about new methodologies for micro-end milling tool design and manufacturing. The machined surface roughness can be improved by appropriately selecting the tool geometrical parameters. PMID:28772479
Reliability and validity of the Dutch pediatric Voice Handicap Index.
Veder, Laura; Pullens, Bas; Timmerman, Marieke; Hoeve, Hans; Joosten, Koen; Hakkesteegt, Marieke
2017-05-01
The pediatric voice handicap index (pVHI) has been developed to provide a better insight into the parents' perception of their child's voice related quality of life. The purpose of the present study was to validate the Dutch pVHI by evaluating its internal consistency and reliability. Furthermore, we determined the optimal cut-off point for a normal pVHI score. All items of the English pVHI were translated into Dutch. Parents of children in our dysphonic and control group were asked to fill out the questionnaire. For the test re-test analysis we used a different study group who filled out the pVHI twice as part of a large follow up study. Internal consistency was analyzed through Cronbach's α coefficient. The test-retest reliability was assessed by determining Pearson's correlation coefficient. Mann-Whitney test was used to compare the scores of the questionnaire of the control group with the dysphonic group. By calculating receiver operating characteristic (ROC) curves, sensitivity and specificity we were able to set a cut-off point. We obtained data from 122 asymptomatic children and from 79 dysphonic children. The scores of the questionnaire significantly differed between both groups. The internal consistency showed an overall Cronbach α coefficient of 0.96 and an excellent test-retest reliability of the total pVHI questionnaire with a Pearson's correlation coefficient of 0.90. A cut-off point for the total pVHI questionnaire was set at 7 points with a specificity of 85% and sensitivity of 100%. A cut-off point for the VAS score was set at 13 with a specificity of 93% and sensitivity of 97%. The Dutch pVHI is a valid and reliable tool for the assessment of children with voice problems. By setting a cut-off point for the score of the total pVHI questionnaire of 7 points and the VAS score of 13, the pVHI might be used as a screening tool to assess dysphonic complaints and the pVHI might be a useful and complementary tool to identify children with dysphonia. Copyright © 2017 Elsevier B.V. All rights reserved.
Koh, Bryan T H; Tan, J H; Ramruttun, Amit Kumarsing; Wang, Wilson
2015-11-17
In cemented joint arthroplasty, the handling characteristics (doughing, working, and setting times) of polymethyl methacrylate (PMMA) bone cement is important as it determines the amount of time surgeons have to optimally position an implant. Storage conditions (temperature and humidity) and the time given for PMMA cement to equilibrate to ambient operating theater (OT) temperatures are often unregulated and may lead to inconsistencies in its handling characteristics. This has not been previously studied. Hence, the purpose of this study was to investigate the effect of storage temperatures on the handling characteristics of PMMA cement and the duration of equilibration time needed at each storage temperature to produce consistent and reproducible doughing, setting, and working times. SmartSet® HV cement was stored at three different controlled temperatures: 20 °C (control), 24 °C, and 28 °C for at least 24 h prior to mixing. The cement components were then brought into a room kept at 20 °C and 50 % humidity. Samples were allowed to equilibrate to ambient conditions for 15, 30, 45, and 60 min. The cement components were mixed and the dough time, temperature-versus-time curve (Lutron TM-947SD, Lutron Electronics, Inc., Coopersburg, PA), and setting time were recorded. Analysis was performed using the two-way ANOVA test (IBM SPSS Statistics V.22). At 20 °C (control) storage temperature, the mean setting time was 534 ± 17 s. At 24 °C storage temperature, the mean setting time was 414 ± 6 s (p < 0.001*) with 15 min of equilibration, 446 ± 11 s (p < 0.001*) with 30 min of equilibration, 501 ± 12 s (p < 0.001*) with 45 min of equilibration, and 528 ± 15 (p > 0.05) with 60 min of equilibration. At 28 °C storage temperature, the mean setting time was 381 ± 8 s (p < 0.001*) with 15 min of equilibration, 432 ± 30 s (p < 0.001*) with 30 min of equilibration, 487 ± 9 (p < 0.001*) with 45 min of equilibration, and 520 ± 16 s (p > 0.05) with 60 min of equilibration. This study reflects the extent to which storage temperatures and equilibration times can potentially affect the handling characteristics of PMMA cement. We recommend institutions to have a well-regulated temperature and humidity-controlled facility for storage of bone cements and a protocol to standardize the equilibration time of cements prior to use in the OT to improve consistency and reproducibility of the handling characteristics of PMMA cement.
Morrill, K M; Polo, J; Lago, A; Campbell, J; Quigley, J; Tyler, H
2013-07-01
Objectives of this study were to develop a rapid calf-side test to determine serum IgG concentrations using caprylic acid (CA) fractionation, followed by refractometry of the IgG-rich supernatant and compare the accuracy of this method with results obtained using refractometry using raw serum. Serum samples (n=200) were obtained from 1-d-old calves, frozen (-20°C), and shipped to the laboratory. Samples were allowed to thaw for 1h at room temperature. Fractionation with CA was conducted by adding 1mL of serum to a tube containing 45, 60, or 75µL of CA and 0.5, 1.0, or 1.5mL of 0.06 M acetic acid. The tube contents were mixed well, allowed to react for 1 min, and then centrifuged at 3,300 × g for 0, 10, or 20 min at 25°C. The %Brix and refractive index of the fractionated supernatant were determined using a digital refractometer. Nonfractionated serum was analyzed for %Brix (BRn), refractive index (nDn), and IgG concentration by radial immunodiffusion. The mean serum IgG concentration was 19.0 mg/mL [standard deviation (SD)=9.7], with a range of 3.5 to 47.0 mg/mL. The mean serum BRn was 8.6 (SD=0.91), with a range of 6.8 to 11.0. The mean serum nDn was 1.34566 (SD=0.00140), with a range of 1.34300 to 1.34930. Serum nDn was positively correlated with IgG concentration (correlation coefficient=0.86; n=185). Fractionated samples treated with 1mL 0.6 M acetic acid and 60µL of CA and not centrifuged before analysis resulted in a strong relationship between the refractive index of the fractionated supernatant and IgG (correlation coefficient=0.80; n=45). Regression was used to determine cut points indicative of 10, 12, and 14 mg of IgG/mL to determine the sensitivity and specificity of refractometry to identify failure of passive transfer (serum IgG <10 mg/mL at 24 h old). The nDn were 1.34414, 1.34448, and 1.34480 to predict 10, 12, and 14 mg of IgG/mL of serum, respectively. The BRn cut points were 7.6, 7.8, and 8.0, respectively. The nDn cut points of 1.34448 and 1.34480 resulted in similar specificities (82.9%), whereas the 1.34414 cut point had a specificity of 60.0%. The BRn cut point of 7.6 and 7.8%Brix resulted in a similar percentage of correctly classified samples (89.7 and 90.8%, respectively); however, the 7.8% Brix cut point resulted in fewer false positives. These results suggest that Brix refractometry of nonfractionated calf serum provides a strong estimate of IgG concentration and 7.8% Brix may be used as the cut point to identify failure of passive transfer in 1-d-old calves. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Antibrowning and antimicrobial properties of sodium acid sulfate in apple slices.
Fan, Xuetong; Sokorai, Kimberly J B; Liao, Ching-Hsing; Cooke, Peter; Zhang, Howard Q
2009-01-01
There are few available compounds that can both control browning and enhance microbial safety of fresh-cut fruits. In the present study, the antibrowning ability of sodium acid sulfate (SAS) on "Granny Smith" apple slices was first investigated in terms of optimum concentration and treatment time. In a separate experiment, the apple slices were treated with water or 3% of SAS, calcium ascorbate, citric acid, or acidified calcium sulfate for 5 min. Total plate count, color, firmness, and tissue damage were assessed during a 21-d storage at 4 degrees C. Results showed that the efficacy of SAS in inhibiting browning of apple slices increased with increasing concentration. A minimum 3% of SAS was needed to achieve 14 d of shelf life. Firmness was not significantly affected by SAS at 3% or lower concentrations. Antibrowning potential of SAS was similar for all treatment times ranging from 2 to 10 min. However, SAS caused some skin discoloration of apple slices. When cut surface of apple slices were stained with a fluorescein diacetate solution, tissue damage could be observed under a microscope even though visual damage was not evident. Among the antibrowning agents tested, SAS was the most effective in inhibiting browning and microbial growth for the first 14 d. Total plate count of samples treated with 3% SAS was significantly lower than those treated with calcium ascorbate, a commonly used antibrowning agent. Our results suggested that it is possible to use SAS to control browning while inhibiting the growth of microorganisms on the apple slices if the skin damage can be minimized. Practical Application: Fresh-cut apples have emerged as one of the popular products in restaurants, schools, and food service establishments as more consumers demand fresh, convenient, and nutritious foods. Processing of fresh-cut apples induces mechanical damage to the fruit and exposes apple tissue to air, resulting in the development of undesirable tissue browning. The fresh-cut industry currently uses antibrowning agents to prevent discoloration. However, the antibrowning solutions can become contaminated with human pathogens such as Listeria monocytogenes, and washing of apple slices with the contaminated solutions can result in the transfer of pathogens to the product. It would be ideal if an antibrowning compound prevented the proliferation of human pathogens in solutions and minimized the growth of pathogens during storage. The study was conducted to investigate antibrowning and antimicrobial properties of sodium acid sulfate (SAS) in comparison with other common antibrowning agents on Granny Smith apples. Results showed that among the antimicrobial agents we tested, SAS was the most effective in inhibiting browning and microbial growth for 14 d at 4 degrees C. However, SAS caused some skin discoloration of apple slices. Overall, SAS can potentially be used to inhibit tissue browning while reducing the microbial growth on apple slices. The information is useful for the fresh-cut produce industry to enhance microbial safety of fresh-cut apples while minimizing browning, thus increasing the consumption of the health benefiting fresh fruit.
NASA Technical Reports Server (NTRS)
Lewis, E. V.
1985-01-01
Aft end of auger, like forward, face-piercing end, equipped with hard cutting bits such as diamonds. As auger breaks face, pulls broken coal lumps into jaws and forces them into hardened throat section. There, cutting bits chew up lumps: Clearance between throat and auger shaft sets maximum size for coal particles that pass through. Auger motion pushes coal particles into mixing chamber, where paddles combine them with water.
Growth after partial cutting of ponderosa pine on permanent sample plots in eastern Oregon.
Edwin L. Mowat
1961-01-01
Between the years 1913 and 1938, seven sets of permanent sample plots were established on the Whitman, Malheur, Rogue River, and Deschutes National Forests in eastern and central Oregon to study the results of various methods of selection cutting in old-growth ponderosa pine stands. This report briefly describes these studies and gives statistics on board-foot growth...
Validity of Alternative Cut-Off Scores for the Back-Saver Sit and Reach Test
ERIC Educational Resources Information Center
Looney, Marilyn A.; Gilbert, Jennie
2012-01-01
The purpose of the study was to determine if currently used FITNESSGRAM[R] cut-off scores for the Back Saver Sit and Reach Test had the best criterion-referenced validity evidence for 6-12 year old children. Secondary analyses of an existing data set focused on the passive straight leg raise and Back Saver Sit and Reach Test flexibility scores of…
Single Piezo-Actuator Rotary-Hammering (SPaRH) Drill
NASA Technical Reports Server (NTRS)
Sherrit, Stewart (Inventor); Bao, Xiaoqi (Inventor); Badescu, Mircea (Inventor); Bar-Cohen, Yoseph (Inventor)
2014-01-01
A Single Piezo-Actuator Rotary-Hammering (SPaRH) Drill includes a horn actuator having high power piezoelectric materials and a flexure pre-stress to increase the actuators effectiveness. The drill is a low mass, low power, compact coring drill measuring 20-cm high by 7-cm diameter and having a total weight of 2 kg including drive electronics. Using an average power of 50-Watts, the drill basalt is expected to cut basalt at a rate of 0.2 cm/min down to depth of 10-cm and create cuttings and an intact core. The drill is expected to operate under different environments including Martian ambient (6 Torr and down to -50 degree C), and liquid nitrogen temperatures (77 K) and low pressure (<<1 Torr) to simulate lunar polar and Europa conditions. Materials expected to be sampled include Kaolinite, Saddleback Basalt, Limestone, Volcanic Breccia, Siltstone, ice, permafrost and layered rocks with different hardness.
An Interactive Image Segmentation Method in Hand Gesture Recognition
Chen, Disi; Li, Gongfa; Sun, Ying; Kong, Jianyi; Jiang, Guozhang; Tang, Heng; Ju, Zhaojie; Yu, Hui; Liu, Honghai
2017-01-01
In order to improve the recognition rate of hand gestures a new interactive image segmentation method for hand gesture recognition is presented, and popular methods, e.g., Graph cut, Random walker, Interactive image segmentation using geodesic star convexity, are studied in this article. The Gaussian Mixture Model was employed for image modelling and the iteration of Expectation Maximum algorithm learns the parameters of Gaussian Mixture Model. We apply a Gibbs random field to the image segmentation and minimize the Gibbs Energy using Min-cut theorem to find the optimal segmentation. The segmentation result of our method is tested on an image dataset and compared with other methods by estimating the region accuracy and boundary accuracy. Finally five kinds of hand gestures in different backgrounds are tested on our experimental platform, and the sparse representation algorithm is used, proving that the segmentation of hand gesture images helps to improve the recognition accuracy. PMID:28134818
Paknejad, Masih; Abdullah, Amir; Azarhoushang, Bahman
2017-11-01
Temperature history and distribution of steel workpiece (X20Cr13) was measured by a high tech infrared camera under ultrasonic assisted dry creep feed up grinding. For this purpose, a special experimental setup was designed and fabricated to vibrate only workpiece along two directions by a high power ultrasonic transducer. In this study, ultrasonic effects with respect to grinding parameters including depth of cut (a e ), feed speed (v w ), and cutting speed (v s ) has been investigated. The results indicate that the ultrasonic vibration has considerable effect on reduction of temperature, depth of thermal damage of workpiece and width of temperature contours. Maximum temperature reduction of 25.91% was reported at condition of v s =15m/s, v w =500mm/min, a e =0.4mm in the presence of ultrasonic vibration. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Jamil, N. A. M.; Azmi, A. I.; Fairuz, M. A.
2016-02-01
This research experimentally investigates the performance of a TiAlN coated carbide drill bit in drilling AISI P20 through two different kinds of lubricants, namely; soluble coconut oil (SCO) and nanoparticle-enhanced coconut oil (NECO) under minimum quantity lubrication system. The tool life and tool wear mechanism were studied using various cutting speeds of 50, 100 and 150 m/min with a constant feed of 0.01 mm/rev. Since the flank wear land was not regular along the cutting edge, the average flank wear (VB) was measured at several points using image analysis software. The drills were inspected using a scanning electron microscope to further elucidate the wear mechanism. The result indicates that drilling with the nanoparticle- enhanced lubricant was better in resisting the wear and improving the drill life to some extent
Carnation (Dianthus caryophylus L.).
Nontaswatsri, Chalermsri; Fukai, Seiichi
2006-01-01
Carnation is a valuable crop for the cut flower industry and demand for new and improved varieties is growing. However, genetic transformation of carnations is currently limited because of a lack of efficient routine technique. In this chapter, we present an easy and effective protocol for gene transfer to carnation node explants and subsequent adventitious shoot regeneration. For high-adventitious shoot regeneration, node explants from first to third node of 5- to 8-cm long shoots were cultured on Murashige and Skoog (MS) medium, containing 1.0 mg/Lthidiazuron (TDZ), 0.1 mg/L alpha-napthalenoacetic acid (NAA), 20 g/L sucrose, and 2 g/L Gellan gum for 10 d. Then the explants were cut into 8 radial segments and subcultured onto MS medium, containing 1.0 mg/L BA, 0.1 mg/L NAA, 20 g/L sucrose and 2 g/L Gellan Gum. For effective genetic transformation, 3- to 5-d precultured node explants were submerged in an Agrobacerium suspension for 10 min, then cocultivated on filter paper soaked with water and 50 microM acetosyringone (AS). After cocultivation, the explants were cut into eight radial segments and subcultured onto selection medium until transformed shoots regenerated from the explants.
Coolant effectiveness in dental cutting with air-turbine handpieces.
Leung, Brian T W; Dyson, John E; Darvell, Brian W
2012-03-01
To establish a strategy for evaluating coolant effectiveness and to compare typical cooling conditions used in dental cutting. A test system comprising a resistive heat source and an array of four type K thermocouples was used to compare the cooling effectiveness of air alone, water stream alone, and an air-water spray, as delivered by representative air-turbine handpieces. Mean temperature change at the four sites was recorded for a range of water flow rates in the range 10 to 90 mL min(-1), with and without air, and with and without the turbine running. The thermal resistance of the system, R, was calculated as the temperature change per watt (KW(-1)). For wet cooling (water stream and air-water spray), R was 5.1 to 11.5 KW(-1), whereas for air coolant alone the range was 18.5 to 30.7 KW(-1). R for air-water spray was lower than for water stream cooling at the same flow rate. The thermal resistivity approach is a viable means of comparative testing of cooling efficacy in simulated dental cutting. It may provide a reliable means of testing handpiece nozzle design, thus enabling the development of more efficient cooling.
Code of Federal Regulations, 2013 CFR
2013-07-01
... installed: (a) Cutting paraffin; (b) Removing and setting pump-through-type tubing plugs, gas-lift valves...) Corrosion inhibitor treatment; (i) Removing or replacing subsurface pumps; (j) Through-tubing logging (diagnostics); (k) Wireline fishing; and (l) Setting and retrieving other subsurface flow-control devices...
Code of Federal Regulations, 2014 CFR
2014-07-01
... installed: (a) Cutting paraffin; (b) Removing and setting pump-through-type tubing plugs, gas-lift valves...) Corrosion inhibitor treatment; (i) Removing or replacing subsurface pumps; (j) Through-tubing logging (diagnostics); (k) Wireline fishing; and (l) Setting and retrieving other subsurface flow-control devices...
Code of Federal Regulations, 2012 CFR
2012-07-01
... installed: (a) Cutting paraffin; (b) Removing and setting pump-through-type tubing plugs, gas-lift valves...) Corrosion inhibitor treatment; (i) Removing or replacing subsurface pumps; (j) Through-tubing logging (diagnostics); (k) Wireline fishing; and (l) Setting and retrieving other subsurface flow-control devices...
76 FR 50184 - Procurement List, Additions and Deletions
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-12
..., Giant Cupcake, 3pc NSN: M.R. 1151--Set, Pan, Bake, Perfect Brownie Pan, 3pc NSN: M.R. 1152--Set, Pasta Cooker, Blue, Pasta Express, 7pc NSN: M.R. 1155--Glove, Oven, Flexi NSN: M.R. 1156--Device, Cutting...
Abulon, Dina Joy K; Buboltz, David C
2015-02-01
To measure flow rate of balanced salt solution and IOP during simulated vitrectomy using two sets of high-speed dual-pneumatic probes. A closed-model eye system measured IOP and flow rate of a balanced salt solution through infusion cannula. The Constellation Vision System was tested with two sets of high-speed dual-pneumatic probes (UltraVit 23-gauge and enhanced 25+-gauge 5000-cpm probes; UltraVit 23-gauge and enhanced 25+-gauge 7500-cpm probes; n = 6 each) under different vacuum levels and cut rates in three duty cycle modes. In both probe sets, flow rates were dependent on cut rate with the biased open and biased closed duty cycles. Flow rates were highest with the biased open duty cycle, lower with the 50/50 duty cycle, and lowest with the biased closed duty cycle. IOP, as expected, was inversely associated with flow rate using both probe sets. The 7500-cpm probes offer greater control and customization compared with 5000-cpm probes under certain experimental conditions. At maximum cut rates, performance of 7500-cpm probes was similar to that of 5000-cpm probes, suggesting that 7500-cpm probes may be used without sacrifice of flow rate and IOP stability. Customization of vitrectomy parameters allows greater surgeon control during vitrectomy and may expand the usefulness of vitrectomy probes.
NASA Astrophysics Data System (ADS)
Mia, Mozammel; Bashir, Mahmood Al; Dhar, Nikhil Ranjan
2016-07-01
Hard turning is gradually replacing the time consuming conventional turning process, which is typically followed by grinding, by producing surface quality compatible to grinding. The hard turned surface roughness depends on the cutting parameters, machining environments and tool insert configurations. In this article the variation of the surface roughness of the produced surfaces with the changes in tool insert configuration, use of coolant and different cutting parameters (cutting speed, feed rate) has been investigated. This investigation was performed in machining AISI 1060 steel, hardened to 56 HRC by heat treatment, using coated carbide inserts under two different machining environments. The depth of cut, fluid pressure and material hardness were kept constant. The Design of Experiment (DOE) was performed to determine the number and combination sets of different cutting parameters. A full factorial analysis has been performed to examine the effect of main factors as well as interaction effect of factors on surface roughness. A statistical analysis of variance (ANOVA) was employed to determine the combined effect of cutting parameters, environment and tool configuration. The result of this analysis reveals that environment has the most significant impact on surface roughness followed by feed rate and tool configuration respectively.
A Fiscal Cliff: The Current U.S. Federal Budget, Potential Cuts, and Impacts on Science Funding
NASA Astrophysics Data System (ADS)
Uhlenbrock, K. M.; Landau, E. A.; Hankin, E. R.
2012-12-01
As lawmakers on Capitol Hill face challenges to reach an agreement on how to cut the deficit while growing the economy, scientists must join the discussion and outline the serious impacts cuts to federal science programs will have on our society. Consistent and sustained federal science funding (discretionary spending) is an ever increasing struggle with the rising costs of mandatory spending and decrease in revenues. In 2011 Congress passed the Budget Control Act, which will require automatic across-the-board cuts, known as sequestration, and will take effect on 2 January 2013. Estimated cuts of $1.2 trillion and discretionary spending caps set at Fiscal Year 2012 levels will trigger non-defense program cuts of 9.8% in the first year as reported by the Congressional Research Service. Funding from non-defense program agencies such as NSF, NASA, DOE, NOAA, USGS, and others drive science and technological innovation, support public safety, create jobs, educate generations of scientists, stimulate the economy, protect our environment, and enrich lives. With non-defense discretionary programs representing less than one-fifth of the federal budget, severe cuts to these programs will not alleviate our deficit, but instead restrict our growth.
Shendell, Derek G; Mizan, Samina S; Marshall, Elizabeth G; Kelly, Sarah W; Therkorn, Jennifer H; Campbell, Jennifer K; Miller, Ashley E
2012-09-01
Investigations of young workers, including limited surveys in supervised school settings, suggested their elevated injury risk. This study identified factors contributing to cuts-lacerations among adolescents in New Jersey secondary school career, technical, and vocational education programs. Of 1,772 injuries reported between December 1, 1998, and September 1, 2010, 777 (44%) were cuts-lacerations; analyses focused on 224 reports (n = 182 post-exclusions) submitted after fall 2005 in three career groups-Food, Hospitality & Tourism (FH&T) (n = 71), Manufacturing & Construction (M&C) (n = 84), and Automotive & Transportation (A&T) (n = 27). Most students were "struck by" tools or hard surfaces (n = 93, 51%); 63 cuts were from knives in FH&T. In M&C, most cuts-lacerations were caused by hand-held tools (n = 18) and being "struck against/by" or "caught between hard surfaces" (n = 19). Males reported more cuts-lacerations (n = 145), most commonly among 11th graders (n = 54) and ages 16 to 17 years (n = 79). Fingers (n = 117) were most often injured, usually by cutting tools (n = 83). Training, supervision, and appropriate equipment, and further assessments of "struck by" and "pinch point" hazards, are needed. Copyright 2012, SLACK Incorporated.
Schreurs, Mervin J; Benjaminse, Anne; Lemmink, Koen A P M
2017-10-03
Cutting is an important skill in team-sports, but unfortunately is also related to non-contact ACL injuries. The purpose was to examine knee kinetics and kinematics at different cutting angles. 13 males and 16 females performed cuts at different angles (45°, 90°, 135° and 180°) at maximum speed. 3D kinematics and kinetics were collected. To determine differences across cutting angles (45°, 90°, 135° and 180°) and sex (female, male), a 4×2 repeated measures ANOVA was conducted followed by post hoc comparisons (Bonferroni) with alpha level set at α≤0.05a priori. At all cutting angles, males showed greater knee flexion angles than females (p<0.01). Also, where males performed all cutting angles with no differences in the amount of knee flexion -42.53°±8.95°, females decreased their knee flexion angle from -40.6°±7.2° when cutting at 45° to -36.81°±9.10° when cutting at 90°, 135° and 180° (p<0.01). Knee flexion moment decreased for both sexes when cutting towards sharper angles (p<0.05). At 90°, 135° and 180°, males showed greater knee valgus moments than females. For both sexes, knee valgus moment increased towards the sharper cutting angles and then stabilized compared to the 45° cutting angle (p<0.01). Both females and males showed smaller vGRF when cutting to sharper angles (p<0.01). It can be concluded that different cutting angles demand different knee kinematics and kinetics. Sharper cutting angles place the knee more at risk. However, females and males handle this differently, which has implications for injury prevention. Copyright © 2017 Elsevier Ltd. All rights reserved.
Cutting the Flesh: Surgery, Autopsy and Cannibalism in the Belgian Congo
Au, Sokhieng
2017-01-01
Within the colonial setting of the Belgian Congo, the process of cutting the body, whether living or dead, lent itself to conflation with cannibalism and other fantastic consumption stories by both Congolese and Belgian observers. In part this was due to the instability of the meaning of the human body and the human corpse in the colonial setting. This essay maps out different views of the cadaver and personhood through medical technologies of opening the body in the Belgian Congo. The attempt to impose a specific reading of the human body on the Congolese populations through anatomy and related Western medical disciplines was unsuccessful. Ultimately, practices such as surgery and autopsy were reinterpreted and reshaped in the colonial context, as were the definitions of social and medical death. By examining the conflicts that arose around medical technologies of cutting human flesh, this essay traces multiple parallel narratives on acceptable use and representation of the human body (Congolese or Belgian) beyond its medical assignation. PMID:28260570
Morgan, Ryan W; French, Benjamin; Kilbaugh, Todd J; Naim, Maryam Y; Wolfe, Heather; Bratinov, George; Shoap, Wesley; Hsieh, Ting-Chang; Nadkarni, Vinay M; Berg, Robert A; Sutton, Robert M
2016-07-01
The American Heart Association (AHA) recommends monitoring invasive arterial diastolic blood pressure (DBP) and end-tidal carbon dioxide (ETCO2) during cardiopulmonary resuscitation (CPR) when available. In intensive care unit patients, both may be available to the rescuer. The objective of this study was to compare DBP vs. ETCO2 during CPR as predictors of cardiac arrest survival. In two models of cardiac arrest (primary ventricular fibrillation [VF] and asphyxia-associated VF), 3-month old swine received either standard AHA guideline-based CPR or patient-centric, BP-guided CPR. Mean values of DBP and ETCO2 in the final 2min before the first defibrillation attempt were compared using receiver operating characteristic curves (area under curve [AUC] analysis). The optimal DBP cut point to predict survival was derived and subsequently validated in two independent, randomly generated cohorts. Of 60 animals, 37 (61.7%) survived to 45min. DBP was higher in survivors than in non-survivors (40.6±1.8mmHg vs. 25.9±2.4mmHg; p<0.001), while ETCO2 was not different (30.0±1.5mmHg vs. 32.5±1.8mmHg; p=0.30). By AUC analysis, DBP was superior to ETCO2 (0.82 vs. 0.60; p=0.025) in discriminating survivors from non-survivors. The optimal DBP cut point in the derivation cohort was 34.1mmHg. In the validation cohort, this cut point demonstrated a sensitivity of 0.78, specificity of 0.81, positive predictive value of 0.64, and negative predictive value of 0.89 for survival. In both primary and asphyxia-associated VF porcine models of cardiac arrest, DBP discriminates survivors from non-survivors better than ETCO2. Failure to attain a DBP >34mmHg during CPR is highly predictive of non-survival. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Duncan, Michael J; Vale, Susana; Santos, Maria Paula; Ribeiro, José Carlos; Mota, Jorge
2013-01-01
To examine the efficacy of aerobic fitness thresholds in predicting weight status and cardiovascular disease risk (CVD) in young people. A cross-sectional school-based study was conducted on 414 Portuguese young people (235 girls and 179 boys) aged 10-16 years (Mean age ± SD = 13.6 ± 1. 8 years). Height and mass were assessed to determine body mass index (BMI). The 20 m multistage shuttle-fitness test (MSFT) was used as an estimate of aerobic fitness. Capillary blood sampling was used to determine: total cholesterol, triglycerides, high-, and low-density lipoprotein. These were combined with measures of systolic blood pressure as z-scores and summed to create a CVD risk score. Analysis of covariance, controlling for sexual maturation, indicated a significant main effect for BMI as a result of fitness category (P = 0.0001). When applied to CVD risk data, there was no difference between "fit" and "unfit" groups (P = 0.136). Subsequent receiver operating curve (ROC) analysis indicated significant diagnostic accuracy of 20 mMSFT performance for boys and girls (both P = 0.0001) with subsequent cut-offs of estimated VO2 peak of 49.5 ml kg(-1) min(-1) for girls and 47.7 ml kg(-1) min(-1) for boys. When applied to BMI and CVD risk data, there was a significant main effect as a result of fitness category for BMI (P = 0.0001) and CVD risk score (P = 0.0001). Recently established cut-points proposed by Boddy et al. (Boddy et al. [2012]: PLoS One 7(9): e45755) show validity in distinguishing between weight status but not CVD risk in Portuguese young people. Alternative ROC generated cut points significantly predicted BMI and CVD risk in this sample. Copyright © 2013 Wiley Periodicals, Inc.
Open pit mining profit maximization considering selling stage and waste rehabilitation cost
NASA Astrophysics Data System (ADS)
Muttaqin, B. I. A.; Rosyidi, C. N.
2017-11-01
In open pit mining activities, determination of the cut-off grade becomes crucial for the company since the cut-off grade affects how much profit will be earned for the mining company. In this study, we developed a cut-off grade determination mode for the open pit mining industry considering the cost of mining, waste removal (rehabilitation) cost, processing cost, fixed cost, and selling stage cost. The main goal of this study is to develop a model of cut-off grade determination to get the maximum total profit. Secondly, this study is also developed to observe the model of sensitivity based on changes in the cost components. The optimization results show that the models can help mining company managers to determine the optimal cut-off grade and also estimate how much profit that can be earned by the mining company. To illustrate the application of the models, a numerical example and a set of sensitivity analysis are presented. From the results of sensitivity analysis, we conclude that the changes in the sales price greatly affects the optimal cut-off value and the total profit.
Effect of magneto rheological damper on tool vibration during hard turning
NASA Astrophysics Data System (ADS)
Paul, P. Sam; Varadarajan, A. S.
2012-12-01
Recently, the concept of hard turning has gained considerable attention in metal cutting as it can apparently replace the traditional process cycle of turning, heat treating, and finish grinding for assembly of hard wear resistant steel parts. The present investigation aims at developing a magneto rheological (MR) fluid damper for suppressing tool vibration and promoting better cutting performance during hard turning. The magneto rheological Fluid acts as a viscoelastic spring with non-linear vibration characteristics that are controlled by the composition of the magneto rheological fluid, the shape of the plunger and the electric parameters of the magnetizing field. Cutting experiments were conducted to arrive at a set of electrical, compositional and shape parameters that can suppress tool vibration and promote better cutting performance during turning of AISI 4340 steel of 46 HRC with minimal fluid application using hard metal insert with sculptured rake face. It was observed that the use of MR fluid damper reduces tool vibration and improves the cutting performance effectively. Also commercialization of this idea holds promise to the metal cutting industry.
Thorlacius, Linnea; Gyldenløve, Mette; Zachariae, Claus; Carlsen, Berit C
2015-10-01
Hyperhidrosis is a condition in which the production of sweat is abnormally increased. No objective criteria for the diagnosis of hyperhidrosis exist, mainly because reference intervals for normal physiological sweat production at rest are unknown. The main objective of this study was to establish reference intervals for normal physiological axillary and palmar sweat production. Gravimetric testing was performed in 75 healthy control subjects. Subsequently, these results were compared with findings in a cohort of patients with hyperhidrosis and with the results derived from a review of data on hyperhidrosis published between 1980 and 2013. Approximately 90% of the controls had axillary and palmar sweat production rates of below 100 mg/5 min. In all except one of the axillary and palmar hyperhidrosis studies reviewed, average sweat production exceeded 100 mg/5 min. A sweat production rate of 100 mg/5 min as measured by gravimetric testing may be a reasonable cut-off value for distinguishing axillary and palmar hyperhidrosis from normal physiological sweat production. © 2015 The International Society of Dermatology.
Willford, Wayne A.; Hesselberg, Robert J.; Bergman, Harold L.
1973-01-01
Total mercury in a variety of substances is determined rapidly and precisely by direct sample combustion, collection of released mercury by amalgamation, and photometric measurement of mercury volatilized from the heated amalgam. Up to 0.2 g fish tissue is heated in a stream of O2 (1.2 L/min) for 3.5 min in 1 tube of a 2-tube induction furnace. The released mercury vapor and combustion products are carried by the stream of O2 through a series of traps (6% NaOH scrubber, water condenser, and Mg(CIO4)2 drying tube) and the mercury is collected in a 10 mm diameter column of 24 gauge gold wire (8 g) cut into 3 mm lengths. The resulting amalgam is heated in the second tube of the induction furnace and the volatilized mercury is measured with a mercury vapor meter equipped with a recorder-integrator. Total analysis time is approximately 8 min/sample. The detection limit is less than 0.002 μg and the system is easily converted for use with other biological materials, water, and sediments.
Hierarchy of Certain Types of DNA Splicing Systems
NASA Astrophysics Data System (ADS)
Yusof, Yuhani; Sarmin, Nor Haniza; Goode, T. Elizabeth; Mahmud, Mazri; Heng, Fong Wan
A Head splicing system (H-system)consists of a finite set of strings (words) written over a finite alphabet, along with a finite set of rules that acts on the strings by iterated cutting and pasting to create a splicing language. Any interpretation that is aligned with Tom Head's original idea is one in which the strings represent double-stranded deoxyribonucleic acid (dsDNA) and the rules represent the cutting and pasting action of restriction enzymes and ligase, respectively. A new way of writing the rule sets is adopted so as to make the biological interpretation transparent. This approach is used in a formal language- theoretic analysis of the hierarchy of certain classes of splicing systems, namely simple, semi-simple and semi-null splicing systems. The relations between such systems and their associated languages are given as theorems, corollaries and counterexamples.
Effects of different modes of exercise on appetite and appetite-regulating hormones.
Kawano, Hiroshi; Mineta, Mayuko; Asaka, Meiko; Miyashita, Masashi; Numao, Shigeharu; Gando, Yuko; Ando, Takafumi; Sakamoto, Shizuo; Higuchi, Mitsuru
2013-07-01
The present study determined the changes in appetite and appetite-regulating gut hormones during and following bouts of both rope skipping exercise (weight-bearing) and bicycle ergometer exercise (non-weight-bearing). After a 12-h fast, 15 young men (mean ± SD, age 24.4 ± 1.7 yrs, maximal oxygen uptake 47.0 ± 6.5 mL/kg/min) participated in three 160 min trials: (1) rope skipping exercise (295 ± 40 kcal, 3 sets × 10 min with 5-min interval, then rested for 120 min); (2) bicycle ergometer exercise (288 ± 36 kcal, 3 sets × 10 min with 5-min interval, then rested for 120 min); (3) control (rested for 160 min). Ratings of perceived hunger and acylated ghrelin were suppressed and total peptide YY (PYY) were increased during and immediately after exercise in both exercise trials, but glucagon liked peptide-1 was not changed. Furthermore, suppressed hunger during rope skipping exercise was greater than that during bicycle ergometer exercise, but there were no differences in acylated ghrelin and total PYY. These results indicate that weight-bearing exercise has a greater exercise-induced appetite suppressive effect compared with non-weight-bearing exercise, and both forms of exercise lowered acylated ghrelin and increased total PYY, but the changes did not differ significantly between exercise modes. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Liggett, M. A.; Childs, J. F.
1973-01-01
The author has identified the following significant results. Geologic reconnaissance guided by analysis of ERTS-1 and Apollo-9 satellite imagery and intermediate scale photography from X-15 and U-2 aircraft has confirmed the presence of a major fault zone along the California-Nevada state line, between 35 deg 30 min and 36 deg 30 min north latitude. The name Pahrump Fault Zone has been suggested for this feature after the valley in which it is best exposed. Field reconnaissance has indicated the existence of previously unreported faults cutting bedrock along range fronts, and displacing Tertiary and Quaternary basin sediments. Gravity data support the interpretation of regional structural discontinuity along this zone. Individual fault traces within the Pahrump Fault Zone form generally left-stepping en echelon patterns. These fault patterns, the apparent offset of a Laramide age thrust fault, and possible drag folding along a major fault break suggest a component of right lateral displacement. The trend and postulated movement of the Pahrump Fault Zone are similar to the adjacent Las Vegas Shear Zone and Death Valley-Furnace Creek Faults, which are parts of a regional strike slip system in the southern Basin-Range Province.
Cai, L; Wen, Y; Jiang, M; Zeng, M; Zhang, B
2016-05-01
Mismatch of partners in premature ejaculation (PE) regarding intra-vaginal ejaculation latency time (IELT) is usually neglected. Here we proposed the concept and evaluated the use of index of IELT (IIELT) as an objective diagnostic tool for PE. Data from 103 self-reporting PE patients and 59 normal controls were collected. The expected IELTs of both the male and female partners were provided by each participating couple in two questionnaires. IIELT=stopwatch IELT/(1/2 the male's expected IELT+1/2 the female's expected IELT). The stopwatch IELTs were 1.74±1.4 min (PE group) and 14.45±11.0 min (control group), P<0.05. The expected IELTs were 15.65±8.7 min (men) and 14.16±6.9 min (women) in the PE group, and 21.3±16.1 min (men) and 20.04±13.47 min (women) in the control group, P<0.05. The calculated IIELTs were 0.14±0.12 (PE group) and 0.83±0.60 (control group), P<0.05. The best cut-off point was 0.658, the Youden index was 0.652, sensitivity was 0.991, specificity was 0.661, positive predictive probability was 83.46% and negative predictive probability was 97.6%. We concluded that IIELT was an integrated measurement of the couples' sexual equilibrium and demonstrated that it provided a simple and objective screening indicator for diagnosing self-reported PE.
Govindasamy-Lucey, S; Jaeggi, J J; Martinelli, C; Johnson, M E; Lucey, J A
2011-06-01
Fortification of cheesemilk with membrane retentates is often practiced by cheesemakers to increase yield. However, the higher casein (CN) content can alter coagulation characteristics, which may affect cheese yield and quality. The objective of this study was to evaluate the effect of using ultrafiltration (UF) retentates that were processed at low temperatures on the properties of Swiss cheese. Because of the faster clotting observed with fortified milks, we also investigated the effects of altering the coagulation conditions by reducing the renneting temperature (from 32.2 to 28.3°C) and allowing a longer renneting time before cutting (i.e., giving an extra 5min). Milks with elevated total solids (TS; ∼13.4%) were made by blending whole milk retentates (26.5% TS, 7.7% CN, 11.5% fat) obtained by cold (<7°C) UF with part skim milk (11.4% TS, 2.5% CN, 2.6% fat) to obtain milk with CN:fat ratio of approximately 0.87. Control cheeses were made from part-skim milk (11.5% TS, 2.5% CN, 2.8% fat). Three types of UF fortified cheeses were manufactured by altering the renneting temperature and renneting time: high renneting temperature=32.2°C (UFHT), low renneting temperature=28.3°C (UFLT), and a low renneting temperature (28.3°C) plus longer cutting time (+5min compared to UFLT; UFLTL). Cutting times, as selected by a Wisconsin licensed cheesemaker, were approximately 21, 31, 35, and 32min for UFHT, UFLT, UFLTL, and control milks, respectively. Storage moduli of gels at cutting were lower for the UFHT and UFLT samples compared with UFLTL or control. Yield stress values of gels from the UF-fortified milks were higher than those of control milks, and decreasing the renneting temperature reduced the yield stress values. Increasing the cutting time for the gels made from the UF-fortified milks resulted in an increase in yield stress values. Yield strain values were significantly lower in gels made from control or UFLTL milks compared with gels made from UFHT or UFLT milks. Cheese composition did not differ except for fat content, which was lower in the control compared with the UF-fortified cheeses. No residual lactose or galactose remained in the cheeses after 2 mo of ripening. Fat recoveries were similar in control, UFHT, and UFLTL but lower in UFLT cheeses. Significantly higher N recoveries were obtained in the UF-fortified cheeses compared with control cheese. Because of higher fat and CN contents, cheese yield was significantly higher in UF-fortified cheeses (∼11.0 to 11.2%) compared with control cheese (∼8.5%). A significant reduction was observed in volume of whey produced from cheese made from UF-fortified milk and in these wheys, the protein was a higher proportion of the solids. During ripening, the pH values and 12% trichloroacetic acid-soluble N levels were similar for all cheeses. No differences were observed in the sensory properties of the cheeses. The use of UF retentates improved cheese yield with no significant effect on ripening or sensory quality. The faster coagulation and gel firming can be decreased by altering the renneting conditions. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
A Critical Analysis of the Body of Work Method for Setting Cut-Scores
ERIC Educational Resources Information Center
Radwan, Nizam; Rogers, W. Todd
2006-01-01
The recent increase in the use of constructed-response items in educational assessment and the dissatisfaction with the nature of the decision that the judges must make using traditional standard-setting methods created a need to develop new and effective standard-setting procedures for tests that include both multiple-choice and…
Effect of Content Knowledge on Angoff-Style Standard Setting Judgments
ERIC Educational Resources Information Center
Margolis, Melissa J.; Mee, Janet; Clauser, Brian E.; Winward, Marcia; Clauser, Jerome C.
2016-01-01
Evidence to support the credibility of standard setting procedures is a critical part of the validity argument for decisions made based on tests that are used for classification. One area in which there has been limited empirical study is the impact of standard setting judge selection on the resulting cut score. One important issue related to…
ERIC Educational Resources Information Center
Ohio State Univ., Columbus. National Center for Research in Vocational Education.
This course, for individualized or group instruction on ceramic tile setting, was developed from military sources for use in vocational education. The course provides students with skills in mortar preparation, surface preparation, tile layout planning, tile setting, tile cutting, and the grouting of tile joints. Both theory and shop assignments…
Sazili, A. Q.; Norbaiyah, B.; Zulkifli, I.; Goh, Y. M.; Lotfi, M.; Small, A. H.
2013-01-01
This study provides a comparative analysis of the effects of pre-slaughter penetrative and non-penetrative stunning and post-slaughter stunning on meat quality attributes in longissimus lumborum (LL) and semitendinosus (ST) muscles in heifers. Ten animals were assigned to each of four treatment groups: i) animals were subjected to conventional Halal slaughter (a clean incision through the structures at the front of the upper neck - the trachea, oesophagus, carotid arteries and jugular veins) and post-cut penetrating mechanical stun within 10 to 20 s of the neck cut (Unstunned; US); ii) high power non-penetrating mechanical stunning followed by the neck cut (HPNP); iii) low power non-penetrating mechanical stunning followed by the neck cut (LPNP); and iv) penetrative stunning using a captive bolt pistol followed by the neck cut (P). For each carcass, muscle samples were removed within 45 min of slaughter, portioned and analysed for pH, cooking loss, water holding capacity (WHC), tenderness (WBS), lipid oxidation (TBARS) and color, over a two week storage period. Stunning did not affect pH and cooking loss. Significant differences in water holding capacity, tenderness, lipid oxidation and color were present at different storage time points. HPNP stunning resulted in lower WHC and color values, particularly lightness (L*), higher TBARS values and peak force values compared with those stunned using LPNP, P and US. These adverse effects on quality were mostly encountered in the ST muscle. In conclusion, the meat quality achieved using P, LPNP and US treatments was comparable, and no treatment stood out as considerably better than another. PMID:25049845
Growth of Listeria spp. in shredded cabbage is enhanced by a mild heat treatment.
Ells, Timothy C; Truelstrup Hansen, Lisbeth
2010-03-01
Mild thermal processing can enhance the shelf life of cut fruits and vegetables by delaying the onset of spoilage and preserving the organoleptic properties of shredded cabbage. However, food safety issues related to this process have not been fully investigated. Therefore, the survival and growth of Listeria spp. on cabbage treated in this manner was examined. Experimentally, 24 strains of Listeria spp. (including L. monocytogenes) were inoculated onto cut and intact cabbage tissues and stored at 5 degrees C. All strains on intact tissues exhibited a moderate decline in numbers (up to 1.0 log CFU/cm(2)) over the 28-day storage period. Conversely, cut tissue supported growth of most strains during the first 7 to 14 days of incubation with maximum increases of 1.2 log CFU/cm(2). Subsequently, the survival or growth on heat-treated (50 degrees C for 3 min) and untreated shredded cabbage of four L. monocytogenes and four nonpathogenic Listeria spp. strains were compared during storage for 21 days at 5 degrees C. Growth on untreated shred for all strains was similar to the results observed on cut tissue with a maximum increase of approximately 1.0 log CFU/g. However, in the heat-treated cabbage shred all strains displayed a rapid increase in growth (up to 2.5 log CFU/g) during the first 7 days of incubation, which may be indicative of the destruction of an endogenous growth-inhibiting compound within the cabbage. In conclusion, this study shows that mild thermal treatments of cut cabbage may promote pathogen growth if other inimical barriers are not implemented downstream of the thermal treatment.
Performance Analysis of Abrasive Waterjet Machining Process at Low Pressure
NASA Astrophysics Data System (ADS)
Murugan, M.; Gebremariam, MA; Hamedon, Z.; Azhari, A.
2018-03-01
Normally, a commercial waterjet cutting machine can generate water pressure up to 600 MPa. This range of pressure is used to machine a wide variety of materials. Hence, the price of waterjet cutting machine is expensive. Therefore, there is a need to develop a low cost waterjet machine in order to make the technology more accessible for the masses. Due to its low cost, such machines may only be able to generate water pressure at a much reduced rate. The present study attempts to investigate the performance of abrasive water jet machining process at low cutting pressure using self-developed low cost waterjet machine. It aims to study the feasibility of machining various materials at low pressure which later can aid in further development of an effective low cost water jet machine. A total of three different materials were machined at a low pressure of 34 MPa. The materials are mild steel, aluminium alloy 6061 and plastics Delrin®. Furthermore, a traverse rate was varied between 1 to 3 mm/min. The study on cutting performance at low pressure for different materials was conducted in terms of depth penetration, kerf taper ratio and surface roughness. It was found that all samples were able to be machined at low cutting pressure with varied qualities. Also, the depth of penetration decreases with an increase in the traverse rate. Meanwhile, the surface roughness and kerf taper ratio increase with an increase in the traverse rate. It can be concluded that a low cost waterjet machine with a much reduced rate of water pressure can be successfully used for machining certain materials with acceptable qualities.
Mortley, Desmond G.; Bonsi, Conrad K.; Hill, Walter A.; Morris, Carlton E.; Williams, Carol S.; Davis, Ceyla F.; Williams, John W.; Levine, Lanfang H.; Petersen, Barbara V.; Wheeler, Raymond M.
2009-01-01
Because sweetpotato [Ipomoea batatas (L.) Lam.] stem cuttings regenerate very easily and quickly, a study of their early growth and development in microgravity could be useful to an understanding of morphological changes that might occur under such conditions for crops that are propagated vegetatively. An experiment was conducted aboard a U.S. Space Shuttle to investigate the impact of microgravity on root growth, distribution of amyloplasts in the root cells, and on the concentration of soluble sugars and starch in the stems of sweetpotatoes. Twelve stem cuttings of ‘Whatley/Loretan’ sweetpotato (5 cm long) with three to four nodes were grown in each of two plant growth units filled with a nutrient agarose medium impregnated with a half-strength Hoagland solution. One plant growth unit was flown on Space Shuttle Colombia for 5 days, whereas the other remained on the ground as a control. The cuttings were received within 2 h postflight and, along with ground controls, processed in ≈45 min. Adventitious roots were counted, measured, and fixed for electron microscopy and stems frozen for starch and sugar assays. Air samples were collected from the headspace of each plant growth unit for postflight determination of carbon dioxide, oxygen, and ethylene levels. All stem cuttings produced adventitious roots and growth was quite vigorous in both ground-based and flight samples and, except for a slight browning of some root tips in the flight samples, all stem cuttings appeared normal. The roots on the flight cuttings tended to grow in random directions. Also, stem cuttings grown in microgravity had more roots and greater total root length than ground-based controls. Amyloplasts in root cap cells of ground-based controls were evenly sedimented toward one end compared with a more random distribution in the flight samples. The concentration of soluble sugars, glucose, fructose, and sucrose and total starch concentration were all substantially greater in the stems of flight samples than those found in the ground-based samples. Carbon dioxide levels were 50% greater and oxygen marginally lower in the flight plants, whereas ethylene levels were similar and averaged less than 10 nL·L −1. Despite the greater accumulation of carbohydrates in the stems, and greater root growth in the flight cuttings, overall results showed minimal differences in cell development between space flight and ground-based tissues. This suggests that the space flight environment did not adversely impact sweetpotato metabolism and that vegetative cuttings should be an acceptable approach for propagating sweetpotato plants for space applications. PMID:20186286
Pattern detection in forensic case data using graph theory: application to heroin cutting agents.
Terrettaz-Zufferey, Anne-Laure; Ratle, Frédéric; Ribaux, Olivier; Esseiva, Pierre; Kanevski, Mikhail
2007-04-11
Pattern recognition techniques can be very useful in forensic sciences to point out to relevant sets of events and potentially encourage an intelligence-led style of policing. In this study, these techniques have been applied to categorical data corresponding to cutting agents found in heroin seizures. An application of graph theoretic methods has been performed, in order to highlight the possible relationships between the location of seizures and co-occurrences of particular heroin cutting agents. An analysis of the co-occurrences to establish several main combinations has been done. Results illustrate the practical potential of mathematical models in forensic data analysis.
A genetic algorithm used for solving one optimization problem
NASA Astrophysics Data System (ADS)
Shipacheva, E. N.; Petunin, A. A.; Berezin, I. M.
2017-12-01
A problem of minimizing the length of the blank run for a cutting tool during cutting of sheet materials into shaped blanks is discussed. This problem arises during the preparation of control programs for computerized numerical control (CNC) machines. A discrete model of the problem is analogous in setting to the generalized travelling salesman problem with limitations in the form of precursor conditions determined by the technological features of cutting. A certain variant of a genetic algorithm for solving this problem is described. The effect of the parameters of the developed algorithm on the solution result for the problem with limitations is investigated.
Impact of dehydration on a full body resistance exercise protocol.
Kraft, Justin A; Green, James M; Bishop, Phillip A; Richardson, Mark T; Neggers, Yasmin H; Leeper, James D
2010-05-01
This study examined effects of dehydration on a full body resistance exercise workout. Ten males completed two trials: heat exposed (with 100% fluid replacement) (HE) and dehydration (approximately 3% body mass loss with no fluid replacement) (DEHY) achieved via hot water bath (approximately 39 degrees C). Following HE and DEHY, participants performed three sets to failure (using predetermined 12 repetition maximum) of bench press, lat pull down, overhead press, barbell curl, triceps press, and leg press with a 2-min recovery between each set and 2 min between exercises. A paired t test showed total repetitions (all sets combined) were significantly lower for DEHY: (144.1 +/- 26.6 repetitions) versus HE: (169.4 +/- 29.1 repetitions). ANOVAs showed significantly lower repetitions (approximately 1-2 repetitions on average) per exercise for DEHY versus HE (all exercises). Pre-set rate of perceived exertion (RPE) and pre-set heart rate (HR) were significantly higher [approximately 0.6-1.1 units on average in triceps press, leg press, and approached significance in lat pull down (P = 0.14) and approximately 6-13 b min(-1) on average in bench press, lat pull down, triceps press, and approached significance for overhead press (P = 0.10)] in DEHY versus HE. Session RPE difference approached significance (DEHY: 8.6 +/- 1.9, HE: 7.4 +/- 2.3) (P = 0.12). Recovery HR was significantly higher for DEHY (116 +/- 15 b min(-1)) versus HE (105 +/- 13 b min(-1)). Dehydration (approximately 3%) impaired resistance exercise performance, decreased repetitions, increased perceived exertion, and hindered HR recovery. Results highlight the importance of adequate hydration during full body resistance exercise sessions.
Wyland, Timothy P; Van Dorin, Joshua D; Reyes, G Francis Cisco
2015-11-01
Applying accommodating resistance combined with isoinertial resistance has been demonstrated to be effective in improving neuromuscular attributes important for sport performance. The main purpose of this study was to determine whether short sprints can be acutely enhanced after several sets of back squats with or without accommodating resistance. Twenty recreationally resistance-trained males (age: 23.3 ± 4.4 years; height: 178.9 ± 6.5 cm; weight: 88.3 ± 10.8 kg) performed pre-post testing on 9.1-m sprint time. Three different interventions were implemented in randomized order between pre-post 9.1-m sprints. On 3 separate days, subjects either sat for 5 minutes (CTRL), performed 5 sets of 3 repetitions at 85% of their 1 repetition maximum (1RM) with isoinertial load (STND), or performed 5 sets of 3 repetitions at 85% of their 1RM, with 30% of the total resistance coming from elastic band tension (BAND) between pre-post 9.1-m sprint testing. Posttesting for 9.1-m sprint time occurred immediately after the last set of squats (Post-Immediate) and on every minute for 4 minutes after the last set of squats (Post-1min, Post-2min, Post-3min, and Post-4min). Repeated-measures analysis of variance statistical analyses revealed no significant changes in sprint time across posttesting times during the CTRL and STND condition. During the BAND condition, sprint time significantly decreased from Post-Immediate to Post-4min (p = 0.002). The uniqueness of accommodating resistance could create an optimal postactivation potentiation effect to increase neuromuscular performance. Coaches and athletes can implement heavy accommodating resistance exercises to their warm-up when improving acute sprint time is desired.
Zhang, Pin; Liang, Yanmei; Chang, Shengjiang; Fan, Hailun
2013-08-01
Accurate segmentation of renal tissues in abdominal computed tomography (CT) image sequences is an indispensable step for computer-aided diagnosis and pathology detection in clinical applications. In this study, the goal is to develop a radiology tool to extract renal tissues in CT sequences for the management of renal diagnosis and treatments. In this paper, the authors propose a new graph-cuts-based active contours model with an adaptive width of narrow band for kidney extraction in CT image sequences. Based on graph cuts and contextual continuity, the segmentation is carried out slice-by-slice. In the first stage, the middle two adjacent slices in a CT sequence are segmented interactively based on the graph cuts approach. Subsequently, the deformable contour evolves toward the renal boundaries by the proposed model for the kidney extraction of the remaining slices. In this model, the energy function combining boundary with regional information is optimized in the constructed graph and the adaptive search range is determined by contextual continuity and the object size. In addition, in order to reduce the complexity of the min-cut computation, the nodes in the graph only have n-links for fewer edges. The total 30 CT images sequences with normal and pathological renal tissues are used to evaluate the accuracy and effectiveness of our method. The experimental results reveal that the average dice similarity coefficient of these image sequences is from 92.37% to 95.71% and the corresponding standard deviation for each dataset is from 2.18% to 3.87%. In addition, the average automatic segmentation time for one kidney in each slice is about 0.36 s. Integrating the graph-cuts-based active contours model with contextual continuity, the algorithm takes advantages of energy minimization and the characteristics of image sequences. The proposed method achieves effective results for kidney segmentation in CT sequences.
Probst, Danielle R; Gustin, Jillian L; Goodman, Lauren F; Lorenz, Amanda; Wells-Di Gregorio, Sharla M
2016-04-01
Family members of patients who die in an ICU are at increased risk of psychological sequelae compared to those who experience a death in hospice. This study explored differences in rates and levels of complicated grief (CG), posttraumatic stress disorder (PTSD), and depression between family members of patients who died in an ICU versus a non-ICU hospital setting. Differences in family members' most distressing experiences at the patient's end of life were also explored. The study was an observational cohort. Subjects were next of kin of 121 patients who died at a large, Midwestern academic hospital; 77 died in the ICU. Family members completed measures of CG, PTSD, depression, and end-of-life experiences. Participants were primarily Caucasian (93%, N = 111), female (81%, N = 98), spouses (60%, N = 73) of the decedent, and were an average of nine months post-bereavement. Forty percent of family members met the Inventory of Complicated Grief CG cut-off, 31% met the Impact of Events Scale-Revised PTSD cut-off, and 51% met the Center for Epidemiologic Studies Depression Scale depression cut-off. There were no significant differences in rates or levels of CG, PTSD, or depressive symptoms reported by family members between hospital settings. Several distressing experiences were ranked highly by both groups, but each setting presented unique distressing experiences for family members. Psychological distress of family members did not differ by hospital setting, but the most distressing experiences encountered at end of life in each setting highlight potentially unique interventions to reduce distress post-bereavement for family members.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cometto-Muniz, J. Enrique; Cain, William S.; Abraham, Michael H.
Previous research showed a cut-off along homologous volatile organic compounds (VOCs) in their ability to produce acute human mucosal irritation. The present study sought to specify the particular cut-off homolog for sensory eye irritation in an acetate and n-alcohol series. A 1900-ml glass vessel system and a three-alternative forced-choice procedure served to test nonyl, decyl, and dodecyl acetate, and 1-nonanol, 1-decanol, and 1-undecanol. Flowrate to the eye ranged from 2 to 8 L/min and time of exposure from 3 to 24 s. Decyl acetate and 1-undecanol were the shortest homologs that failed to produce eye irritation under all conditions, producingmore » a cut-off effect. Increasing the vapor concentration of decyl acetate and 1-undecanol by 3 and 8 times, respectively, via heating them to 37 deg C made either or both VOCs detectable to only half of the 12 subjects tested, even though the higher vapor concentration was well above a predicted eye irritation threshold. When eye irritation thresholds for homologous acetates and n-alcohols were plotted as a function of the longest unfolded length of the molecule, the values for decyl acetate and 1-undecanol fell within a restricted range of 18 to 19 A. The outcome suggests that the basis for the cut-off is biological, that is, the molecule lacks a key size or structure to trigger transduction, rather than physical, that is, the vapor concentration is too low to precipitate detection.« less
Petri, Eva; Rodríguez, Mariola; García, Silvia
2015-01-01
Most current disinfection strategies for fresh-cut industry are focused on the use of different chemical agents; however, very little has been reported on the effectiveness of the hurdle technology. The effect of combined decontamination methods based on the use of different sanitizers (peroxyacetic acid and chlorine dioxide) and the application of pressure (vacuum/positive pressure) on the inactivation of the foodborne pathogen E. coli O157:H7 on fresh-cut lettuce (Lactuca sativa) and carrots (Daucus carota) was studied. Fresh produce, inoculated with E. coli O157:H7, was immersed (4 °C, 2 min) in tap water (W), chlorine water (CW), chlorine dioxide (ClO2: 2 mg/L) and peroxyacetic acid (PAA: 100 mg/L) in combination with: (a) vacuum (V: 10 mbar) or (b) positive pressure application (P: 3 bar). The product quality and antimicrobial effects of the treatment on bacterial counts were determined both in process washing water and on fresh-cut produce. Evidence obtained in this study, suggests that the use of combined methods (P/V + sanitizers) results in a reduction on the microorganism population on produce similar to that found at atmospheric pressure. Moreover, the application of physical methods led to a significant detrimental effect on the visual quality of lettuce regardless of the solution used. Concerning the process water, PAA proved to be an effective alternative to chlorine for the avoidance of cross-contamination. PMID:26213954
Petri, Eva; Rodríguez, Mariola; García, Silvia
2015-07-23
Most current disinfection strategies for fresh-cut industry are focused on the use of different chemical agents; however, very little has been reported on the effectiveness of the hurdle technology. The effect of combined decontamination methods based on the use of different sanitizers (peroxyacetic acid and chlorine dioxide) and the application of pressure (vacuum/positive pressure) on the inactivation of the foodborne pathogen E. coli O157:H7 on fresh-cut lettuce (Lactuca sativa) and carrots (Daucus carota) was studied. Fresh produce, inoculated with E. coli O157:H7, was immersed (4 °C, 2 min) in tap water (W), chlorine water (CW), chlorine dioxide (ClO2: 2 mg/L) and peroxyacetic acid (PAA: 100 mg/L) in combination with: (a) vacuum (V: 10 mbar) or (b) positive pressure application (P: 3 bar). The product quality and antimicrobial effects of the treatment on bacterial counts were determined both in process washing water and on fresh-cut produce. Evidence obtained in this study, suggests that the use of combined methods (P/V + sanitizers) results in a reduction on the microorganism population on produce similar to that found at atmospheric pressure. Moreover, the application of physical methods led to a significant detrimental effect on the visual quality of lettuce regardless of the solution used. Concerning the process water, PAA proved to be an effective alternative to chlorine for the avoidance of cross-contamination.
Effects of portable computing devices on posture, muscle activation levels and efficiency.
Werth, Abigail; Babski-Reeves, Kari
2014-11-01
Very little research exists on ergonomic exposures when using portable computing devices. This study quantified muscle activity (forearm and neck), posture (wrist, forearm and neck), and performance (gross typing speed and error rates) differences across three portable computing devices (laptop, netbook, and slate computer) and two work settings (desk and computer) during data entry tasks. Twelve participants completed test sessions on a single computer using a test-rest-test protocol (30min of work at one work setting, 15min of rest, 30min of work at the other work setting). The slate computer resulted in significantly more non-neutral wrist, elbow and neck postures, particularly when working on the sofa. Performance on the slate computer was four times less than that of the other computers, though lower muscle activity levels were also found. Potential or injury or illness may be elevated when working on smaller, portable computers in non-traditional work settings. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Optimal atlas construction through hierarchical image registration
NASA Astrophysics Data System (ADS)
Grevera, George J.; Udupa, Jayaram K.; Odhner, Dewey; Torigian, Drew A.
2016-03-01
Atlases (digital or otherwise) are common in medicine. However, there is no standard framework for creating them from medical images. One traditional approach is to pick a representative subject and then proceed to label structures/regions of interest in this image. Another is to create a "mean" or average subject. Atlases may also contain more than a single representative (e.g., the Visible Human contains both a male and a female data set). Other criteria besides gender may be used as well, and the atlas may contain many examples for a given criterion. In this work, we propose that atlases be created in an optimal manner using a well-established graph theoretic approach using a min spanning tree (or more generally, a collection of them). The resulting atlases may contain many examples for a given criterion. In fact, our framework allows for the addition of new subjects to the atlas to allow it to evolve over time. Furthermore, one can apply segmentation methods to the graph (e.g., graph-cut, fuzzy connectedness, or cluster analysis) which allow it to be separated into "sub-atlases" as it evolves. We demonstrate our method by applying it to 50 3D CT data sets of the chest region, and by comparing it to a number of traditional methods using measures such as Mean Squared Difference, Mattes Mutual Information, and Correlation, and for rigid registration. Our results demonstrate that optimal atlases can be constructed in this manner and outperform other methods of construction using freely available software.
Recognising and responding to 'cutting corners' when providing nursing care: a qualitative study.
Jones, Angela; Johnstone, Megan-Jane; Duke, Maxine
2016-08-01
The aim of this study is to report on a key finding of a larger study investigating the 'gaps' in patient care that registered nurses encounter during the course of their practice. A key finding of this larger study was that 'cutting corners' was a gap discerned by nurses. 'Cutting corners' has been characterised as a 'violation' and threat to patient safety, although there is a paucity of research on this issue. Naturalistic inquiry using a qualitative exploratory descriptive approach. Data were collected from a purposeful sample of 71 registered nurses from emergency department, critical care, perioperative, rehabilitation and transitional care and neurosciences settings in Australia and analysed using content and thematic analysis strategies. Cutting corners was a common practice that encompassed (1) the partial or complete omission of patient care, (2) delays in providing care and (3) the failure to do things correctly. Corners were cut in patient assessment, essential nursing care, the care of central venous catheters and medication administration. The practice of cutting corners was perceived as contributing to preventable adverse events. The study found that cutting corners created gaps that contributed to unfinished nursing care and preventable adverse events. The findings of the study raise the possibility that cutting corners is a salient but underinvestigated characteristic of nursing practice. Further research and inquiry are needed to deepen understanding of cutting corners and its impact on patient safety. Identifying the nature and implications of cutting corners when providing nursing care is an important contributing factor to improving patient safety and quality care. © 2016 John Wiley & Sons Ltd.
Schmitz, Randy J; Cone, John C; Copple, Timothy J; Henson, Robert A; Shultz, Sandra J
2014-11-01
Potential biomechanical compensations allowing for maintenance of maximal explosive performance during prolonged intermittent exercise, with respect to the corresponding rise in injury rates during the later stages of exercise or competition, are relatively unknown. To identify lower-extremity countermovement-jump (CMJ) biomechanical factors using a principal-components approach and then examine how these factors changed during a 90-min intermittent-exercise protocol (IEP) while maintaining maximal jump height. Mixed-model design. Laboratory. Fifty-nine intermittent-sport athletes (30 male, 29 female) participated in experimental and control conditions. Before and after a dynamic warm-up and every 15 min during the 1st and 2nd halves of an individually prescribed 90-min IEP, participants were assessed on rating of perceived exertion, sprint/cut speed, and 3-dimensional CMJ biomechanics (experimental). On a separate day, the same measures were obtained every 15 min during 90 min of quiet rest (control). Univariate piecewise growth models analyzed progressive changes in CMJ performance and biomechanical factors extracted from a principal-components analysis of the individual biomechanical dependent variables. While CMJ height was maintained during the 1st and 2nd halves, the body descended less and knee kinetic and energetic magnitudes decreased as the IEP progressed. The results indicate that vertical-jump performance is maintained along with progressive biomechanical changes commonly associated with decreased performance. A better understanding of lower-extremity biomechanics during explosive actions in response to IEP allows us to further develop and individualize performance training programs.
The Unstimulated Salivary Flow Rate in a Jordanian Healthy Adult Population
Sawair, Faleh A.; Ryalat, Soukaina; Shayyab, Mohammad; Saku, Takashi
2009-01-01
Background Early diagnosis of xerostomia is very important for oral health. The purpose of this study was to determine the unstimulated whole salivary flow rates (UWSFR) in a Jordanian Arab population aged 15 years and older. The effect of age, gender, height, weight, body mass index (BMI), smoking, alcohol consumption, and dental conditions, on UWSFR was also investigated. Methods The study was conducted on 244 subjects, 110 males and 134 females, with an average age of 33 ± 15.5 years. They were healthy, unmedicated, and with no history of dry mouth. Unstimulated whole saliva was collected during five minutes, and UWSFRs (ml/min) were determined. Data were analyzed by univariate analysis and multivariate regression analysis. Results The mean UWSFR was 0.46 ± 0.25 ml/min (range: 0.10-1.6 ml/min). Eighteen patients (7.4%) had UWSFR between < 0.20 ml/min. In univariate analysis, UWSFR was significantly affected by age, BMI, number of missing and restored teeth, and DMFT score. Regression analysis revealed that only age and number of missing teeth were of significance in explaining the variability of the UWSFR. Conclusions We established basic standard values of UWSFR to be used in the evaluation of Jordanian patients with complaints of xerostomia and to be compared to data reported in other studies. UWSFR 0.1 ml/min could be considered the cut-off value that distinguishes normal from abnormal salivary function in this healthy unmedicated population. Keywords Whole saliva flow rate; Unstimulated; Jordan PMID:22461872
NASA Astrophysics Data System (ADS)
Naik, Deepak kumar; Maity, K. P.
2018-03-01
Plasma arc cutting (PAC) is a high temperature thermal cutting process employed for the cutting of extensively high strength material which are difficult to cut through any other manufacturing process. This process involves high energized plasma arc to cut any conducting material with better dimensional accuracy in lesser time. This research work presents the effect of process parameter on to the dimensional accuracy of PAC process. The input process parameters were selected as arc voltage, standoff distance and cutting speed. A rectangular plate of 304L stainless steel of 10 mm thickness was taken for the experiment as a workpiece. Stainless steel is very extensively used material in manufacturing industries. Linear dimension were measured following Taguchi’s L16 orthogonal array design approach. Three levels were selected to conduct the experiment for each of the process parameter. In all experiments, clockwise cut direction was followed. The result obtained thorough measurement is further analyzed. Analysis of variance (ANOVA) and Analysis of means (ANOM) were performed to evaluate the effect of each process parameter. ANOVA analysis reveals the effect of input process parameter upon leaner dimension in X axis. The results of the work shows that the optimal setting of process parameter values for the leaner dimension on the X axis. The result of the investigations clearly show that the specific range of input process parameter achieved the improved machinability.
Sigward, Susan M; Cesar, Guilherme M; Havens, Kathryn L
2015-11-01
To compare frontal plane knee moments, and kinematics and kinetics associated with knee valgus moments between cutting to 45 and 110 degrees, and to determine the predictive value of kinematics and ground reaction forces (GRFs) on knee valgus moments when cutting to these angles. Also, to determine whether sex differences exist in kinematics and kinetics when cutting to 45 and 110 degrees. Cross-sectional study. Laboratory setting. Forty-five (20 females) healthy young adult soccer athletes aged 16 to 23 years. Kinematic and kinetic variables were compared between randomly cued side-step cutting maneuvers to 45 and 110 degrees. Predictors of knee valgus moment were determined for each task. Kinematic variables: knee valgus angle, hip abduction, and internal rotation angles. Kinetic variables: vertical, posterior, and lateral GRFs, and knee valgus moment. Knee valgus moments were greater when cutting to 110 degrees compared with 45 degrees, and females exhibited greater moments than males. Vertical and lateral GRFs, hip internal rotation angle, and knee valgus angle explained 63% of the variance in knee valgus moment during cutting to 45 degrees. During cutting to 110 degrees, posterior GRF, hip internal rotation angle, and knee valgus angle explained 41% of the variance in knee valgus moment. Cutting tasks with larger redirection demands result in greater knee valgus moments. Similar factors, including shear GRFs, hip internal rotation, and knee valgus position contribute to knee valgus loading during cuts performed to smaller (45 degrees) and larger (110 degrees) angles. Reducing vertical and shear GRFs during cutting maneuvers may reduce knee valgus moments and thereby potentially reduce risk for anterior cruciate ligament injury.
Reistetter, Timothy A; Graham, James E; Deutsch, Anne; Granger, Carl V; Markello, Samuel; Ottenbacher, Kenneth J
2010-03-01
To evaluate the ability of patient functional status to differentiate between community and institutional discharges after rehabilitation for stroke. Retrospective cross-sectional design. Inpatient rehabilitation facilities contributing to the Uniform Data System for Medical Rehabilitation. Patients (N=157,066) receiving inpatient rehabilitation for stroke from 2006 and 2007. Not applicable. Discharge FIM rating and discharge setting (community vs institutional). Approximately 71% of the sample was discharged to the community. Receiver operating characteristic curve analyses revealed that FIM total performed as well as or better than FIM motor and FIM cognition subscales in differentiating discharge settings. Area under the curve for FIM total was .85, indicating very good ability to identify persons discharged to the community. A FIM total rating of 78 was identified as the optimal cut point for distinguishing between positive (community) and negative (institution) tests. This cut point yielded balanced sensitivity and specificity (both=.77). Discharge planning is complex, involving many factors. Identifying a functional threshold for classifying discharge settings can provide important information to assist in this process. Additional research is needed to determine if the risks and benefits of classification errors justify shifting the cut point to weight either sensitivity or specificity of FIM ratings. Copyright 2010 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
YouTube as a Potential Training Resource for Laparoscopic Fundoplication.
Frongia, Giovanni; Mehrabi, Arianeb; Fonouni, Hamidreza; Rennert, Helga; Golriz, Mohammad; Günther, Patrick
To analyze the surgical proficiency and educational quality of YouTube videos demonstrating laparoscopic fundoplication (LF). In this cross-sectional study, a search was performed on YouTube for videos demonstrating the LF procedure. The surgical and educational proficiency was evaluated using the objective component rating scale, the educational quality rating score, and total video quality score. Statistical significance was determined by analysis of variance, receiver operating characteristic curve, and odds ratio analysis. A total of 71 videos were included in the study; 28 (39.4%) videos were evaluated as good, 23 (32.4%) were moderate, and 20 (28.2%) were poor. Good-rated videos were significantly longer (good, 22.0 ± 5.2min; moderate, 7.8 ± 0.9min; poor, 8.5 ± 1.0min; p = 0.007) and video duration was predictive of good quality (AUC, 0.672 ± 0.067; 95% CI: 0.541-0.802; p = 0.015). For good quality, the cut-off video duration was 7:42 minute. This cut-off value had a sensitivity of 67.9%, a specificity of 60.5%, and an odds ratio of 3.23 (95% CI: 1.19-8.79; p = 0.022) in predicting good quality. Videos uploaded from industrial sources and with a higher views/days online ratio had a higher objective component rating scale and total video quality score. In contrast, the likes/dislikes ratio was not predictive of video quality. Many videos showing the LF procedure have been uploaded to YouTube with varying degrees of quality. A process for filtering LF videos with high surgical and educational quality is feasible by evaluating the video duration, uploading source, and the views/days online ratio. However, alternative videos platforms aimed at professionals should also be considered for educational purposes. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Petraco, Ricardo; Sen, Sayan; Nijjer, Sukhjinder; Echavarria-Pinto, Mauro; Escaned, Javier; Francis, Darrel P; Davies, Justin E
2013-03-01
This study sought to evaluate the effects of fractional flow reserve (FFR) measurement variability on FFR-guided treatment strategy. Current appropriateness guidelines recommend the utilization of FFR to guide coronary revascularization based on a fixed cut-off of 0.8. This rigid approach does not take into account the intrinsic biological variability of a single FFR result and the clinical judgment of experienced interventional cardiologists. [corrected]. FFR reproducibility data from the landmark Deferral Versus Performance of PTCA in Patients Without Documented Ischemia (DEFER) trial was analyzed (two repeated FFR measurements in the same lesion, 10 min apart) and the standard deviation of the difference (SDD) between repeated measurements was calculated. The measurement certainty (probability that the FFR-guided revascularization strategy will not change if the test is repeated 10 min later) was subsequently established across the whole range of FFR values, from 0.2 to 1. Outside the [0.75 to 0.85] FFR range, measurement certainty of a single FFR result is >95%. However, closer to its cut-off, certainty falls to less than 80% within 0.77 to 0.83, reaching a nadir of 50% around 0.8. In clinical practice, that means that each time a single FFR value falls between 0.75 and 0.85, there is a chance that the FFR-derived revascularization recommendation will change if the measurement is repeated 10 min later, with this chance increasing the closer the FFR result is to 0.8. A measurement FFR gray-zone is found between 0.75 and 0.85]. Therefore, clinicians should make revascularization decisions based on broadened clinical judgment when a single FFR result falls within this uncertainty zone, particularly between 0.77 and 0.83, when measurement certainty falls to less than 80%. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Shu, Yingjie; Huang, Liyan; Chen, Ming; Tao, Yuan; Wang, Zhankui; Ma, Hao
2017-06-25
Young leaves of Kabuli chickpea as well as soybean Xiangdou No.3, which are the current plants that studied in our laboratory were selected as materials. Effects on protoplasts yield and survival rate of different enzyme combination, concentration of D-Mannitol in enzyme combinations, pH of enzyme combinations and enzymolysis time are detected. The results showed that, the best condition for Xiangdou No.3 leaf protoplasts isolation is to rotate the cut materials for 6 hours in enyzme solution under temperature of 27 ℃ and rotate speed of 45 r/min for 6 h. Onozuka R-10 (0.5%), Hemicellulase (0.8%), Macerozyme R-10 (0.8%) in combination with Pectolyase Y-23 (0.4%) dissolving in CPW solution with MES (0.1%) and Mannitol (10%), pH 6.0 was found best for protoplasts isolation of Xiangdou No.3 leaves.The best condition for protoplasts isolation of Kabuli chickpea is to put the cut materials into enzymatic hydrolysate enzymolyse for 7 to 8 hours under temperature of 27 ℃ and rotate speed of 45 r/min on water bath shaker, the optimum combination of enzyme consists of Onozuka R-10 (0.5%), Hemicellulase (0.8%), Macerozyme R-10 (0.8%), MES (0.1%) and Mannitol (10%) dissolved in CPW solution with pH 4.8. The protoplasts prepared with the methods above are used in subcellular location and the effects show well.
An optimized 13C-urea breath test for the diagnosis of H pylori infection
Campuzano-Maya, Germán
2007-01-01
AIM: To validate an optimized 13C-urea breath test (13C-UBT) protocol for the diagnosis of H pylori infection that is cost-efficient and maintains excellent diagnostic accuracy. METHODS: 70 healthy volunteers were tested with two simplified 13C-UBT protocols, with test meal (Protocol 2) and without test meal (Protocol 1). Breath samples were collected at 10, 20 and 30 min after ingestion of 50 mg 13C-urea dissolved in 10 mL of water, taken as a single swallow, followed by 200 mL of water (pH 6.0) and a circular motion around the waistline to homogenize the urea solution. Performance of both protocols was analyzed at various cut-off values. Results were validated against the European protocol. RESULTS: According to the reference protocol, 65.7% individuals were positive for H pylori infection and 34.3% were negative. There were no significant differences in the ability of both protocols to correctly identify positive and negative H pylori individuals. However, only Protocol 1 with no test meal achieved accuracy, sensitivity, specificity, positive and negative predictive values of 100%. The highest values achieved by Protocol 2 were 98.57%, 97.83%, 100%, 100% and 100%, respectively. CONCLUSION: A 10 min, 50 mg 13C-UBT with no test meal using a cut-off value of 2-2.5 is a highly accurate test for the diagnosis of H pylori infection at a reduced cost. PMID:17907288
Quality factors in beef, pork, and lamb cooked by microwaves.
Korschgen, B M; Baldwin, R E; Snider, S
1976-12-01
Three cooking treatments were applied to the longissimus muscle of beef and of pork and to deboned leg of lamb. Cooking treatments included: Intermittent energy application (3-min. cycle) with a microwave range operated at 220V and intermittent energy application (6-min. cycle) with a microwave range operated at 115V. Control roasts were cooked in a conventional gas oven (163+/-3 degrees C.). Cooking was adjusted so that roasts achieved an internal temperature of 70 degrees C. when cut for analyses. Cooking losses were significantly greater for microwave than for conventionally cooked beef. However, microwave cooking resulted in beef, pork, and lamb roasts with flavor of interior portions similar to those prepared conventionally. Flavor differences in samples from the edge of the slices of lamb and of pork and tenderness of lamb appeared to be related to cooking method. For these attributes, meat cooked conventionally was superior. In contrast, patterns in significant differences in tenderness and juiciness of beef and of pork were not consistent and were not related solely to method of cookery. Neither creatine nor creatinine was a good index of flavor of meat cooked by these methods. Aside from the time-saving aspect of microwave heating, there was no major advantage of one method of cooking over another. Thus, either high- or low- powered microwave equipment, operated at 2450 MHz, can be used satisfactorily for cooking tender cuts of beef, pork, and lamb.
Ronquillo, Cecinio C; Zaugg, Brian; Stagg, Brian; Kirk, Kevin R; Gupta, Isha; Barlow, William R; Pettey, Jeff H; Olson, Randall J
2014-12-01
To determine the optimal longitudinal power settings for Infiniti OZil Intelligent Phaco (IP) at varying torsional amplitude settings; and to test the hypothesis that increasing longitudinal power is more important at lower torsional amplitudes to achieve efficient phacoemulsification. Laboratory investigation. setting: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah. procedure: Individual porcine nuclei were fixed in formalin, then cut into 2.0 mm cubes. Lens cube phacoemulsification was done using OZil IP at 60%, 80%, and 100% torsional amplitude with 0%, 10%, 20%, 30%, 50%, 75%, or 100% longitudinal power. All experiments were done using a 20 gauge 0.9 mm bent reverse bevel phaco tip at constant vacuum (550 mm Hg), aspiration rate (40 mL/min), and bottle height (50 cm). main outcome measure: Complete lens particle phacoemulsification (efficiency). Linear regression analysis showed a significant increase in efficiency with increasing longitudinal power at 60% torsional amplitude (R(2) = 0.7269, P = .01) and 80% torsional amplitude (R(2) = 0.6995, P = .02) but not at 100% amplitude (R(2) = 0.3053, P = .2). Baseline comparison of 60% or 80% vs 100% torsional amplitude without longitudinal power showed increased efficiency at 100% (P = .0004). Increasing longitudinal power to 20% abolished the efficiency difference between 80% vs 100% amplitudes. In contrast, 75% longitudinal power abolished the efficiency difference between 60% vs 100% torsional amplitudes. Results suggest that longitudinal power becomes more critical at increasing phacoemulsification efficiencies at torsional amplitudes less than 100%. Increasing longitudinal power does not further increase efficiency at maximal torsional amplitudes. Copyright © 2014 Elsevier Inc. All rights reserved.
Banach, J L; van Overbeek, L S; Nierop Groot, M N; van der Zouwen, P S; van der Fels-Klerx, H J
2018-03-23
Controlling water quality is critical in preventing cross-contamination during fresh produce washing. Process wash water (PWW) quality can be controlled by implementing chemical disinfection strategies. The aim of this study was to evaluate the pilot-scale efficacy of chlorine dioxide (ClO 2 ) during processing on the reduction of Escherichia coli in the PWW and on processed fresh-cut 'Lollo Rossa' lettuce. The objective was to have a residual target concentration of either 5 or 3 mg/L ClO 2 in the washing tank (3.5 m 3 ) before and during 800 kg of lettuce processing (90 min). After 90 min., a nonpathogenic, non-Extended Spectrum Beta-Lactamase (ESBL) E. coli inoculum from an overnight culture broth (37 °C) was added to the tank resulting in an approximate final level of 10 6 CFU/mL. PWW and lettuce samples for microbiological and chemical analyses were taken before and after the input and supply halted. ClO 2 concentrations quickly decreased after ClO 2 input halted, yet a residual concentration of ≥2.5 mg/L and ≥2.1 mg/L ClO 2 , respectively for 5 and 3 mg/L pilots, was present 12 min after the supply halted. No detectable levels of E. coli (limit of detection 5 log) were determined in the water within 1 min after E. coli was added to the ClO 2 containing wash water. Results demonstrated that ClO 2 use at the semi-commercial pilot scale was able to reduce the E. coli peak contamination in the PWW. After storage (5 days, 4 °C), background microbial communities (i.e., fluorescent Pseudomonads and total heterotrophic bacteria) grew out on lettuce. Overall, ClO 2 decreased the potential for cross-contamination between batches compared to when no sanitizer was used. Chlorate levels of the lettuce sampled before entering the wash water ranged from 7.3-11.6 μg/kg. The chlorate levels of the lettuce sampled after being washed in the ClO 2 containing wash water, as well as after rinsing and centrifugation, ranged from 22.8-60.4 μg/kg; chlorite levels ranged from 1.3-1.6 mg/kg, while perchlorate levels were below the limit of quantification (LOQ, <5 ng/g). In this study, we report the semi-commercial pilot-scale evaluation of ClO 2 , for its ability to maintain the PWW quality and to prevent cross-contamination in the washing tank during fresh-cut lettuce processing. Furthermore, we provide quantitative values of ClO 2 disinfection by-products chlorate and chlorite as well as of perchlorate from PWW and/or lettuce samples. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
POP, A. B.; ȚÎȚU, M. A.
2016-11-01
In the metal cutting process, surface quality is intrinsically related to the cutting parameters and to the cutting tool geometry. At the same time, metal cutting processes are closely related to the machining costs. The purpose of this paper is to reduce manufacturing costs and processing time. A study was made, based on the mathematical modelling of the average of the absolute value deviation (Ra) resulting from the end milling process on 7136 aluminium alloy, depending on cutting process parameters. The novel element brought by this paper is the 7136 aluminium alloy type, chosen to conduct the experiments, which is a material developed and patented by Universal Alloy Corporation. This aluminium alloy is used in the aircraft industry to make parts from extruded profiles, and it has not been studied for the proposed research direction. Based on this research, a mathematical model of surface roughness Ra was established according to the cutting parameters studied in a set experimental field. A regression analysis was performed, which identified the quantitative relationships between cutting parameters and the surface roughness. Using the variance analysis ANOVA, the degree of confidence for the achieved results by the regression equation was determined, and the suitability of this equation at every point of the experimental field.
System and method for measuring residual stress
Prime, Michael B.
2002-01-01
The present invention is a method and system for determining the residual stress within an elastic object. In the method, an elastic object is cut along a path having a known configuration. The cut creates a portion of the object having a new free surface. The free surface then deforms to a contour which is different from the path. Next, the contour is measured to determine how much deformation has occurred across the new free surface. Points defining the contour are collected in an empirical data set. The portion of the object is then modeled in a computer simulator. The points in the empirical data set are entered into the computer simulator. The computer simulator then calculates the residual stress along the path which caused the points within the object to move to the positions measured in the empirical data set. The calculated residual stress is then presented in a useful format to an analyst.
NASA Astrophysics Data System (ADS)
Ukar, Estibalitz; Lopez, Ramiro G.; Laubach, Stephen E.; Gale, Julia F. W.; Manceda, René; Marrett, Randall
2017-11-01
Shales of the Upper Jurassic-Lower Cretaceous Vaca Muerta Formation are the main source rock for petroleum in the Neuquén Basin, Argentina and an important unconventional exploration target. Folded Vaca Muerta Formation is well exposed in the Agrio Fold-and-Thrust belt where an arid climate and rapid erosion reveal relatively unweathered shale strata accessible along creek beds at Arroyo Mulichinco and in 10+ m-tall cliffs at Puesto. Widespread within these organic-rich shales are several cm-thick, prominent bed-parallel veins (BPVs) of fibrous calcite (beef) that are cut by multiple sets of vertical calcite lined or filled fractures having apertures unaffected by near-surface stress release. Similar, and probably contemporaneous fractures are present within horizons of interbedded dolomitic rock. Evidence that vertical fractures in BPVs and dolomitic horizons continue into shale beds suggests that in-depth analysis of vertical fractures within BPVs and dolomitic horizons allows fracture set and orientation identification and size population measurements-primarily aperture distributions-that circumvent some of the limitations of shale outcrops. At Arroyo Mulichinco, four main fracture sets are present separable by orientation and crosscutting relations. An E-W set is oldest, followed by successively younger NE-SW, NW-SE, and N-S sets. At Puesto, the E-W and N-S sets are the most prominent and show opposite cross-cutting relationships (E-W set is youngest) indicating a possible episode of younger E-W fractures. The E-W set shows the highest micro-and macrofracture intensity at both localities. The intensity of N-S micro- and macrofractures is similar at both outcrops away from faults, but macrofracture intensity increases closer to faults. While macrofracture abundance is similar in BPVs and in shale, microfractures having apertures smaller than ∼0.1 mm are mostly absent in shale and dolomitic layers but are abundant cutting BPVs. Thus, microfractures are BPV-bounded and only fractures wider than ∼0.05 mm are tall enough to cut into shale. Nevertheless, using size distributions of microfractures in BPVs that are absent in shale accurately predicts the abundance of macrofractures in nearby shale, either because microfractures in organic shale have annealed, or because of only small differences in fracture strain for fractures of different sizes across different rocks types. Microfractures in readily sampled BPVs may be a practical way to diagnose or predict attributes of macrofractures in adjacent shale.
Robert H. Ruth; Carl M. Berntsen
1955-01-01
Four years' measurement of seed fall in the spruce-hemlock type on the Cascade Head Experimental Forest indicates that an ample supply of seed is distributed over clear-cut areas under staggered-setting cutting. The largest tract sampled was 81 acres; in spite of a seed crop failure in 1950, it received an average of 243,000 viable spruce and hemlock seeds per...
Beaulieu, John C; Ingber, Bruce F; Lea, Jeanne M
2011-09-01
Previous research examined sanitation treatments on cut cantaloupe tissue to deliver germicidal and food safety effects. However, an apparent compromise between volatile loss and treatment/sampling efficacy appeared. Subsequently, a physiological and volatile reassessment of thinly sliced tissue against cubes was performed in cantaloupe tissue. Thin sliced cantaloupe L* decreased 27.5%, 40.5%, and 52.9% in 3, 2, and 1 mm thickness, respectively, compared with cut cubes after 3 d. Overall color (C) decreased in freshly prepared cubes (2.4%) and slices (14.4%) that were washed in cold water. Surface area per unit volume (SA: vol) in slices was 4.1 times greater than typical cubes, as reflected by substantial water loss (20.4%, 9.5%, and 6.7% in 1, 2 and 3-mm slices, respectively) after 1 d at 5 °C. Rinsing cubes and thin-slices with 5 °C deionized water resulted in roughly 15% soluble solids loss. SEM indicated 65.4% reduced cell size in 1-d old thin slices, evidenced by excessive cell damage and desiccation compared with stored fresh-cut cubes. In thin-sliced tissue exposed 15 min to an open atmosphere (mimic sanitation treatments), total esters decreased 92.8% and 95.8%, respectively, after 1 and 3 d storage at 5 °C. Washing tissue provided a boundary layer that reduced short-term ester losses in slices and cubes. Excessive cutting, sanitation treatment regimes, and storage can radically alter the desirable volatile profile of cut cantaloupe. Reduction of tissue size to maximize food-safety sanitation efficacy or delivering items to a niche market will need substantial work to engineer equipment and develop protocols to insure that product quality and volatiles are not compromised. We have demonstrated that cutting method and sampling protocol are critically important when using volatiles as a means by which to assess or interpret stress response and ascribe fresh-cut quality. Reduction of tissue size to maximize food-safety sanitation efficacy (for example, thin slices) will need substantial work to engineer equipment and design protocols to insure product quality and volatile profiles are not compromised. Journal of Food Science © 2011 Institute of Food Technologists® No claim to original US government works.
Sun, Xue-Yi; Yu, Zhi; Chen, Zhi-Yu; Xu, Bin
2018-02-25
To observe the effect of manual acupuncture stimulation of different layers (skin, muscle, peritoneum, sub-peritoneum) of "Tianshu" (ST 25) region on proximal colonic pressure in normal rats. Forty-eight male SD rats were divided into 6 groups: all layer-needling, brushing, cutaneous needling, muscular needling, peritoneum-needling and sub-peritoneum-needling groups ( n =8 in each group). Manual needling or brushing was applied to "Tianshu" (ST 25) region. The colonic internal pressure was measured by using an amplifier and a pressure transducer-connected balloon which was implanted into the colonic cavity about 6 cm from the ileocecal valve. For rats of the all-layer needling group, an acupuncture needle was inserted into ST 25 about 1 cm deep and rotated for a while, for rats of the brushing group, a Chinese calligraphy brush pen was used to brush the skin hair for 1 min. For rats of the rest 4 groups, an acupuncture needle was inserted into the skin, muscle layer after cutting open the skin (about 0.1 cm), the peritoneum layer after cutting open the skin and muscle layers, and the sub-peritoneum layer after cutting open the skin, muscle and peritoneum layers, respectively, and rotated using the uniform reinforcing-reducing technique for about 1 min at a frequency of 120 twirlings per minute every time. During manual needling stimulation of the full layers, cutaneous layer, muscle layer, peritoneum layer and the sub-peritoneum layer of bilateral "Tianshu" (ST 25), the internal pressure of proximal colon was significantly decreased relevant to pre-stimulation in each group ( P <0.05), and there were no significant differences between bilateral sides needling stimulation in the decreased pressure levels ( P >0.05). During hair brushing of ST 25 region, the colonic pressure was observably increased relevant to pre-needling stimulation ( P <0.05). One min after the acupuncture stimulation, the decreased pressures maintained in needling the all-layer on the left side, needling the skin on the right side, needling the peritoneum layer on both sides, and needling the sub-peritoneum layer on both sides relevant to the brushing group of the same side ( P <0.05). Manual acupuncture stimulation of each layer tissue of ST 25 on both sides may lower internal pressure of proximal colon in normal rats, suggesting their involvement of acupuncture effect in relaxing proximal colonic contraction.
Fabrication technology of Si face and m face on 4H-SiC (0001) epi-layer based on molten KOH etching
NASA Astrophysics Data System (ADS)
Lin, Wen-kui; Zeng, Chun-hong; Sun, Yu-hua; Zhang, Xuan; Li, Zhe; Yang, Tao-tao; Ju, Tao; Zhang, Bao-shun
2018-02-01
Additional scattering of electrons in the complex MOSFET channel caused by off-cut angle of (0001) 4H-SiC wafer, makes accurate crystal face acquisition much desired. Molten KOH was used to etch the circular grooves on the SiC wafer surface in muffle furnace, and hexagonal grooves with SiC crystal symmetry were obtained. Average etching rates at 500°C along <11-20> and <1-100> direction were about 4.826 um/min and 4.112 um/min, respectively,with a etching anisotropy ratio of 1.18. The m face was obtained by controlling the etching time and Si face was obtained by selfstopping effect. The method we developed in this paper has potential applications in the accurate crystal face acquisition of (0001) 4H-SiC epi-wafer, and the preparation of structures based on 4H-SiC.
Messas, Emmanuel; Bel, Alain; Szymanski, Catherine; Cohen, Iris; Touchot, Bernard; Handschumacher, Mark D; Desnos, Michel; Carpentier, Alain; Menasché, Philippe; Hagège, Albert A; Levine, Robert A
2010-11-01
one of the key targets in treating mitral regurgitation (MR) is reducing the otherwise progressive left ventricular (LV) remodeling that exacerbates MR and conveys adverse prognosis. We have previously demonstrated that severing 2 second-order chordae to the anterior mitral leaflet relieves tethering and ischemic MR acutely. The purpose of this study was to test whether this technique reduces the progression of LV remodeling in the chronic ischemic MR setting. a posterolateral MI was created in 18 sheep by obtuse marginal branch ligation. After chronic remodeling and MR development at 3 months, 6 sheep were randomized to sham surgery (control group) and 12 to second-order chordal cutting (6 each to anterior leaflet [AntL] and bileaflet [BiL] chordal cutting, techniques that are in clinical application). At baseline, chronic infarction (3 months), and follow-up at a mean of 6.6 months post-myocardial infarction (MI) (euthanasia), we measured LV end-diastolic (EDV) and end-systolic volume (ESV), ejection fraction, wall motion score index, and posterior leaflet (PL) restriction angle relative to the annulus by 2D and 3D echocardiography. All measurements were comparable among groups at baseline and chronic MI. At euthanasia, AntL and BiL chordal cutting limited the progressive remodeling seen in controls. LVESV increased relative to chronic MI by 109±8.7% in controls versus 30.5±6.1% with chordal cutting (P<0.01) (LVESV in controls, 82.5±2.6 mL; in AntL, 60.6±5.1 mL; in BiL, 61.8±4.1 mL). LVEDV increased by 63±2.0% in controls versus 26±5.5% and 22±3.4% with chordal cutting (P<0.01). LV ejection fraction and wall motion score index were not significantly different at follow-up among the chordal cutting and control groups. MR progressively increased to moderate in controls but decreased to trace-mild with AntL and BiL chordal cutting (MR vena contracta in controls, 5.9±1.1 mm; in AntL, 2.6±0.1 mm; in BiL, 1.7±0.1 mm; P<0.01). BiL chordal cutting provided greater PL mobility (decreased PL restriction angle to 54.2±5.0° versus 83±3.2° with AntL chordal cutting; P<0.01). reduced leaflet tethering by chordal cutting in the chronic post-MI setting substantially decreases the progression of LV remodeling with sustained reduction of MR over a chronic follow-up. These benefits have the potential to improve clinical outcomes.
Funkenbusch, Paul D; Rotella, Mario; Chochlidakis, Konstantinos; Ercoli, Carlo
2016-10-01
Laboratory studies of tooth preparation often involve single values for all variables other than the one being tested. In contrast, in clinical settings, not all variables can be adequately controlled. For example, a new dental rotary cutting instrument may be tested in the laboratory by making a specific cut with a fixed force, but, in clinical practice, the instrument must make different cuts with individual dentists applying different forces. Therefore, the broad applicability of laboratory results to diverse clinical conditions is uncertain and the comparison of effects across studies difficult. The purpose of this in vitro study was to examine the effects of 9 process variables on the dental cutting of rotary cutting instruments used with an electric handpiece and compare them with those of a previous study that used an air-turbine handpiece. The effects of 9 key process variables on the efficiency of a simulated dental cutting operation were measured. A fractional factorial experiment was conducted by using an electric handpiece in a computer-controlled, dedicated testing apparatus to simulate dental cutting procedures with Macor blocks as the cutting substrate. Analysis of variance (ANOVA) was used to assess the statistical significance (α=.05). Four variables (targeted applied load, cut length, diamond grit size, and cut type) consistently produced large, statistically significant effects, whereas 5 variables (rotation per minute, number of cooling ports, rotary cutting instrument diameter, disposability, and water flow rate) produced relatively small, statistically insignificant effects. These results are generally similar to those previously found for an air-turbine handpiece. Regardless of whether an electric or air-turbine handpiece was used, the control exerted by the dentist, simulated in this study by targeting a specific level of applied force, was the single most important factor affecting cutting efficiency. Cutting efficiency was also significantly affected by factors simulating patient/clinical circumstances and hardware choices. These results highlight the greater importance of local clinical conditions (procedure, dentist) in understanding dental cutting as opposed to other hardware-related factors. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Funkenbusch, Paul D; Rotella, Mario; Ercoli, Carlo
2015-04-01
Laboratory studies of tooth preparation are often performed under a limited range of conditions involving single values for all variables other than the 1 being tested. In contrast, in clinical settings not all variables can be tightly controlled. For example, a new dental rotary cutting instrument may be tested in the laboratory by making a specific cut with a fixed force, but in clinical practice, the instrument must make different cuts with individual dentists applying a range of different forces. Therefore, the broad applicability of laboratory results to diverse clinical conditions is uncertain and the comparison of effects across studies is difficult. The purpose of this study was to examine the effect of 9 process variables on dental cutting in a single experiment, allowing each variable to be robustly tested over a range of values for the other 8 and permitting a direct comparison of the relative importance of each on the cutting process. The effects of 9 key process variables on the efficiency of a simulated dental cutting operation were measured. A fractional factorial experiment was conducted by using a computer-controlled, dedicated testing apparatus to simulate dental cutting procedures and Macor blocks as the cutting substrate. Analysis of Variance (ANOVA) was used to judge the statistical significance (α=.05). Five variables consistently produced large, statistically significant effects (target applied load, cut length, starting rpm, diamond grit size, and cut type), while 4 variables produced relatively small, statistically insignificant effects (number of cooling ports, rotary cutting instrument diameter, disposability, and water flow rate). The control exerted by the dentist, simulated in this study by targeting a specific level of applied force, was the single most important factor affecting cutting efficiency. Cutting efficiency was also significantly affected by factors simulating patient/clinical circumstances as well as hardware choices. These results highlight the importance of local clinical conditions (procedure, dentist) in understanding dental cutting procedures and in designing adequate experimental methodologies for future studies. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
The Role of Construct Maps in Standard Setting
ERIC Educational Resources Information Center
Kane, Michael T.; Tannenbaum, Richard J.
2013-01-01
The authors observe in this commentary that construct maps can help standard-setting panels to make realistic and internally consistent recommendations for performance-level descriptions (PLDs) and cut-scores, but the benefits may not be realized if policymakers do not fully understand the rationale for the recommendations provided by the…
ERIC Educational Resources Information Center
Cravens, Xiu Chen; Goldring, Ellen B.; Porter, Andrew C.; Polikoff, Morgan S.; Murphy, Joseph; Elliott, Stephen N.
2013-01-01
Purpose: Performance evaluation informs professional development and helps school personnel improve student learning. Although psychometric literature indicates that a rational, sound, and coherent standard-setting process adds to the credibility of an assessment, few studies have empirically examined the decision-making process. This article…
1997-02-13
AMINOPROPIOPHENONE IN DOG PLASMA 0 OCH 3 CH2 CH3 OCH2CHOHCH 2 OH H2 N& p-Aminopropiophenone Guaifenesin (WR 000,302) Internal Standard APPROVALS: This Analytical...40 - 80 il VOLUME: RUN TIME: 14 min (PAPP: 10.7 min; Guaifenesin (Internal Standard): 8.5 min) DETECTOR Wavelength: 316 nm SETTINGS: Absorption Range
A method for identifying color vision deficiency malingering.
Pouw, Andrew; Karanjia, Rustum; Sadun, Alfredo
2017-03-01
To propose a new test to identify color vision deficiency malingering. An online survey was distributed to 130 truly color vision deficient participants and 160 participants willing to simulate color vision deficiency. The survey contained three sets of six color-adjusted versions of the standard Ishihara color plates each, as well as one set of six control plates. The plates that best discriminated both participant groups were selected for a "balanced" test emphasizing both sensitivity and specificity. A "specific" test that prioritized high specificity was also created by selecting from these plates. Statistical measures of the test (sensitivity, specificity, and Youden index) were assessed at each possible cut-off threshold, and a receiver operating characteristic (ROC) function with its area under the curve (AUC) charted. The redshift plate set was identified as having the highest difference of means between groups (-58%, CI: -64 to -52%), as well as the widest gap between group modes. Statistical measures of the "balanced" test show an optimal cut-off of at least two incorrectly identified plates to suggest malingering (Youden index: 0.773, sensitivity: 83.3%, specificity: 94.0%, AUC of ROC 0.918). The "specific" test was able to identify color vision deficiency simulators with a specificity of 100% when using a cut-off of at least two incorrectly identified plates (Youden index 0.599, sensitivity 59.9%, specificity 100%, AUC of ROC 0.881). Our proposed test for identifying color vision deficiency malingering demonstrates a high degree of reliability with AUCs of 0.918 and 0.881 for the "balanced" and "specific" tests, respectively. A cut-off threshold of at least two missed plates on the "specific" test was able to identify color vision deficiency simulators with 100% specificity.
Cuschieri, Kate; Cubie, Heather; Graham, Catriona; Rowan, Jennifer; Hardie, Alison; Horne, Andrew; Earle, Camille Busby; Bailey, Andrew; Crosbie, Emma J; Kitchener, Henry
2014-02-01
As HPV testing is used increasingly for cervical disease management, there is a demand to optimise the performance of HPV tests, particularly with respect to specificity. To compare the clinical performance of an HPV DNA and a RNA based test in women with cytological abnormalities. The influence of age and assay cut off on test performance was also assessed. A prospective comparison of the Hybrid Capture 2 test (HC2) and the Aptima HPV assay (AHPV) was performed within a colposcopy setting. Clinical sensitivity and specificity were determined for the detection of cervical intraepithelial neoplasia (CIN) grade 2 or worse. Both assays were >90% sensitive for the detection of CIN2+. AHPV was slightly more specific than HC2 [49.9% (46.8-53.1) vs 45.9% (42.8, 49.1), p<0.0001]. Raising HC2 cut off to 2 RLU did not improve specificity. A cut-off of 10 RLU increased specificity by approximately 10% - although this led to a reduction in sensitivity of 6.3% which equated to 24 missed cases of CIN2+. Both assays were more specific in women over 30 years of age, compared to women under 30 (p<0.001). Although AHPV was more specific than HC2 in the total cohort (p<0.001), we found this difference to be smaller than other studies. This could be attributed to different indications for colposcopic referral across different settings. This study also confirms the relatively poor specificity of commercial HPV assays in women under 30. Copyright © 2013 Elsevier B.V. All rights reserved.
Convex decomposition techniques applied to handlebodies
NASA Astrophysics Data System (ADS)
Ortiz, Marcos A.
Contact structures on 3-manifolds are 2-plane fields satisfying a set of conditions. The study of contact structures can be traced back for over two-hundred years, and has been of interest to mathematicians such as Hamilton, Jacobi, Cartan, and Darboux. In the late 1900's, the study of these structures gained momentum as the work of Eliashberg and Bennequin described subtleties in these structures that could be used to find new invariants. In particular, it was discovered that contact structures fell into two classes: tight and overtwisted. While overtwisted contact structures are relatively well understood, tight contact structures remain an area of active research. One area of active study, in particular, is the classification of tight contact structures on 3-manifolds. This began with Eliashberg, who showed that the standard contact structure in real three-dimensional space is unique, and it has been expanded on since. Some major advancements and new techniques were introduced by Kanda, Honda, Etnyre, Kazez, Matic, and others. Convex decomposition theory was one product of these explorations. This technique involves cutting a manifold along convex surfaces (i.e. surfaces arranged in a particular way in relation to the contact structure) and investigating a particular set on these cutting surfaces to say something about the original contact structure. In the cases where the cutting surfaces are fairly nice, in some sense, Honda established a correspondence between information on the cutting surfaces and the tight contact structures supported by the original manifold. In this thesis, convex surface theory is applied to the case of handlebodies with a restricted class of dividing sets. For some cases, classification is achieved, and for others, some interesting patterns arise and are investigated.
NASA Astrophysics Data System (ADS)
Kaucikas, M.; Warren, M.; Michailovas, A.; Antanavicius, R.; van Thor, J. J.
2013-02-01
This paper describes the investigation of an optical parametric oscillator (OPO) set-up based on two beta barium borate (BBO) crystals, where the interplay between the crystal orientations, cut angles and air dispersion substantially influenced the OPO performance, and especially the angular spectrum of the output beam. Theory suggests that if two BBO crystals are used in this type of design, they should be of different cuts. This paper aims to provide an experimental manifestation of this fact. Furthermore, it has been shown that air dispersion produces similar effects and should be taken into account. An x-ray crystallographic indexing of the crystals was performed as an independent test of the above conclusions.
Fatigue life analysis of cracked gas receiver of emergency cut-off system in gas gathering station
NASA Astrophysics Data System (ADS)
Hu, Junzhi; Zhou, Jiyong; Li, Siyuan
2017-06-01
Small-scale air compressor and gas receiver are used as the driving gas of the emergency cut-off system in gas gathering station. Operation of block valve is ensured by starting and stopping compressor automatically. The frequent start-stop of compressor and the pressure fluctuation pose a threat to the service life of gas receiver, and then affect normal operation of the emergency cut-off system and security of gas gathering station. In this paper, the fatigue life of a pressure vessel with axial semi-elliptical surface crack in the inner wall is analyzed under the varying pressure by means of the theory of fracture mechanics. The influences of the amplitude of pressure fluctuation and the initial crack size on the residual life of gas receiver are discussed. It provides a basis for setting the working parameters of gas receiver of emergency cut-off system and determining the maintenance cycle.
An Integrated Method Based on PSO and EDA for the Max-Cut Problem.
Lin, Geng; Guan, Jian
2016-01-01
The max-cut problem is NP-hard combinatorial optimization problem with many real world applications. In this paper, we propose an integrated method based on particle swarm optimization and estimation of distribution algorithm (PSO-EDA) for solving the max-cut problem. The integrated algorithm overcomes the shortcomings of particle swarm optimization and estimation of distribution algorithm. To enhance the performance of the PSO-EDA, a fast local search procedure is applied. In addition, a path relinking procedure is developed to intensify the search. To evaluate the performance of PSO-EDA, extensive experiments were carried out on two sets of benchmark instances with 800 to 20,000 vertices from the literature. Computational results and comparisons show that PSO-EDA significantly outperforms the existing PSO-based and EDA-based algorithms for the max-cut problem. Compared with other best performing algorithms, PSO-EDA is able to find very competitive results in terms of solution quality.
Gradual cut detection using low-level vision for digital video
NASA Astrophysics Data System (ADS)
Lee, Jae-Hyun; Choi, Yeun-Sung; Jang, Ok-bae
1996-09-01
Digital video computing and organization is one of the important issues in multimedia system, signal compression, or database. Video should be segmented into shots to be used for identification and indexing. This approach requires a suitable method to automatically locate cut points in order to separate shot in a video. Automatic cut detection to isolate shots in a video has received considerable attention due to many practical applications; our video database, browsing, authoring system, retrieval and movie. Previous studies are based on a set of difference mechanisms and they measured the content changes between video frames. But they could not detect more special effects which include dissolve, wipe, fade-in, fade-out, and structured flashing. In this paper, a new cut detection method for gradual transition based on computer vision techniques is proposed. And then, experimental results applied to commercial video are presented and evaluated.
Performance analysis of cutting graphite-epoxy composite using a 90,000psi abrasive waterjet
NASA Astrophysics Data System (ADS)
Choppali, Aiswarya
Graphite-epoxy composites are being widely used in many aerospace and structural applications because of their properties: which include lighter weight, higher strength to weight ratio and a greater flexibility in design. However, the inherent anisotropy of these composites makes it difficult to machine them using conventional methods. To overcome the major issues that develop with conventional machining such as fiber pull out, delamination, heat generation and high tooling costs, an effort is herein made to study abrasive waterjet machining of composites. An abrasive waterjet is used to cut 1" thick graphite epoxy composites based on baseline data obtained from the cutting of ¼" thick material. The objective of this project is to study the surface roughness of the cut surface with a focus on demonstrating the benefits of using higher pressures for cutting composites. The effects of major cutting parameters: jet pressure, traverse speed, abrasive feed rate and cutting head size are studied at different levels. Statistical analysis of the experimental data provides an understanding of the effect of the process parameters on surface roughness. Additionally, the effect of these parameters on the taper angle of the cut is studied. The data is analyzed to obtain a set of process parameters that optimize the cutting of 1" thick graphite-epoxy composite. The statistical analysis is used to validate the experimental data. Costs involved in the cutting process are investigated in term of abrasive consumed to better understand and illustrate the practical benefits of using higher pressures. It is demonstrated that, as pressure increased, ultra-high pressure waterjets produced a better surface quality at a faster traverse rate with lower costs.
NASA Astrophysics Data System (ADS)
Wang, Jiachun; Li, Yuntao; Liu, Xiaoxuan; Lv, Maoqiang
2016-10-01
In the process of cutting silicon by natural diamond tools, groove wear happens on the flank face of cutting tool frequently.Scholars believe that one of the wear reasons is mechanical scratching effect by hard particles like SiC. To reveal the mechanical scratching mechanism, it is essential to study changes in the mechanical properties of hard particles and diamond, especially the effect of cutting temperature on hardness of diamond and hard particles. Molecular dynamics (MD) model that contact-zone temperature between tool and workpiece was calculated by dividing zone while nano-cutting monocrystalline silicon was established, cutting temperature values in different regions were computed as the simulation was carried out.On this basis, the models of molecular dynamics simulation of SiC and diamond were established separately with setting the initial temperature to room temperature. The laws of length change of C-C bond and Si-C bond varing with increase of simulation temperature were studied. And drawing on predecessors' research on theoretical calculation of hardness of covalent crystals and the relationship between crystal valence electron density and bond length, the curves that the hardness of diamond and SiC varing with bond length were obtained. The effect of temperature on the hardness was calculated. Results show that, local cutting temperature can reach 1300K.The rise in cutting temperature leaded to a decrease in the diamond local atomic clusters hardness,SiC local atomic clusters hardness increased. As the cutting temperature was more than 1100K,diamond began to soften, the local clusters hardness was less than that of SiC.
NASA Astrophysics Data System (ADS)
Shi, Zhi-Dong; Lin, Jian-Qiang; Bao, Huan-Huan; Liu, Shu; Xiang, Xue-Nong
2008-03-01
A photoelectric measurement system for measuring the beat length of birefringence fiber is set up including a set of rotating-wave-plate polarimeter using single photodiode. And two improved cutback methods suitable for measuring beat-length within millimeter range of high birefringence fiber are proposed through data processing technique. The cut length needs not to be restricted shorter than one centimeter so that the auto-cleaving machine is freely used, and no need to carefully operate the manually cleaving blade with low efficiency and poor success. The first method adopts the parameter-fitting to a saw-tooth function of tried beat length by the criterion of minimum square deviations, without special limitation on the cut length. The second method adopts linear-fitting in the divided length ranges, only restrict condition is the increment between different cut lengths less than one beat-length. For a section of holey high-birefringence fiber, we do experiments respectively by the two methods. The detecting error of beat-length is discussed and the advantage is compared.
Sex Differences in Cardiac Baroreflex Sensitivity after Isometric Handgrip Exercise.
Teixeira, André L; Ritti-Dias, Raphael; Antonino, Diego; Bottaro, Martim; Millar, Philip J; Vianna, Lauro C
2018-04-01
This study aimed to investigate potential sex-related differences on spontaneous cardiac baroreflex sensitivity (cBRS) after acute isometric handgrip (IHG) exercise. Twenty men (age, 23 ± 3 yr) and 20 women (age, 24 ± 4 yr) randomly performed four sets of 2-min IHG exercise (two sets for each limb) at 30% maximal voluntary contraction (experimental) or 3% maximal voluntary contraction (sham). Beat-to-beat heart rate (HR) and arterial blood pressure (BP) were monitored using finger photoplethysmography before and 10, 20, and 30 min after IHG. Spontaneous cBRS was assessed via the sequence technique and cardiac autonomic modulation via time- and frequency-domain HR variability. After IHG, spontaneous cBRS increased during 10 min of recovery in men (Δ13% ± 5%, P = 0.03 vs rest) and increased further in women (Δ23% ± 4%, P < 0.01 vs rest; P = 0.04 vs men). During 20 and 30 min of recovery, cBRS returned to baseline in men but remained elevated in women. HR decreased 10 min after IHG in men (10 min: Δ-2 ± 1 bpm, P < 0.01 vs rest; 20 min: Δ-1 ± 1 bpm, P = 0.39 vs rest; 30 min: Δ1 ± 1 bpm, P = 0.31 vs rest) and throughout recovery in women (10 min: Δ-5 ± 1 bpm, P < 0.01 vs rest; 20 min: Δ-3 ± 1 bpm, P < 0.01 vs rest; 30 min: Δ-2 ± 1 bpm, P < 0.01 vs rest). Systolic BP increased 10 min after IHG and remained elevated during 20 min and 30 min in men (P < 0.05). In women, systolic BP increased during 10 min (P < 0.01) and returned to baseline during 20 and 30 min of recovery. Time-domain HR variability (root mean square of successive differences) was increased during recovery in men and women (P < 0.05). Sham had no effect on any variables. Acute IHG exercise increases cBRS and cardiac vagal activity in healthy young subjects, but the magnitude and the time course of changes in cBRS differ between men and women.
Sometimes There Is No Most-Vital Arc: Assessing and Improving the Operational Resilience of Systems
2013-01-01
this problem in which the reduction in capacity on each in- terdicted arc is a random variable with known mean and variance , and the overall goal is...capacities will allow. A classic result in the theory of network flows states that the maximum flow volume is equal to the min- imum capacity of any cut, where...attack capability provides a natural means to assess the resilience of the system as a whole. This analysis yields a corollary result that common-sense
A Pilot Study of the Performance Characteristics of the D-dimer in Presumed Sepsis
2010-05-01
20 breaths/min or PaCO2 ថ mm Hg White Blood Cell Count >12,000 cells /mm3, ɜ,000 cells /mm3, or >10% bands Table 2. Sepsis Definitions Sepsis 2 or...Jersey), a quantitative, microlatex agglutination test with a reference cut-off of 0.4 mg/dL as positive. The assay is run on venous blood collected...sensitivity of only ~61- 67% for patients who ultimately were found to have positive blood cultures.12 This study used a semi-quantitative D-dimer
1999-04-01
atrium , the inferior vena cava was closed with a silk ligature and the liver was carefully excised. 2.4 Liver...withdraw needle. 5.5.10 Secure tip of cannula with ligature and connect medium at lowest flow rate (5 mL/min). 5.5.11 Cut inferior vena cava below the...heart. 5.5.14 Cannulate the superior vena cava via an incision in the right atrium , secure with ligature. 5.5.15 Close ligature around inferior vena cava
Lee, J M; Han, J K; Kim, S H; Lee, J Y; Shin, K S; Choi, B I
2005-08-01
To determine optimal parameters for bipolar radiofrequency ablation (RFA) using perfusion-cooled electrodes to create a large ablation volume in ex vivo bovine liver. Three sets of RF experiments were performed using a 200-Watt generator and two 15-gauge perfusion-cooled or internally cooled electrodes in ex vivo bovine livers. In the first set of experiments, to find the ideal inter-electrode distance for creating large coagulation necrosis, 30 ablation lesions were created by bipolar RFAs at inter-electrode spacings of 3 cm, 4 cm, and 5 cm. In the second set of experiments, to explore the ideal duration of RF application, bipolar RFAs were performed for 10 min and 20 min. In the first and second experiments, 10 lesions were made for each condition with infusion of 6% hypertonic saline (HS) at 2 ml/min. In the third set of experiments, 10 ablation lesions were created by bipolar RFAs using internally cooled electrodes without HS infusion. The mean volume of those ablation lesions was then compared to that of the lesions created by bipolar RFA using perfusion-cooled electrodes in the second experiments. Tissue impedance, dimension, and shape of the ablated areas were compared in each condition. In the first set of experiments, bipolar RFA created a homogeneous oval or spherical-shaped ablation area between the electrodes at 3-5 cm spacing, but showed a more spherical-shaped lesion at 3 cm inter-electrode spacing than at 4 cm and 5 cm spacing. In the second set of experiments, RF energy delivered for 20 min created a larger dimension of coagulation necrosis than energy delivered for 10 min: 107.6 +/- 34 cm3 versus 59.5 +/- 27 cm3 (P<0.05). In addition, the mean volume of ablation regions obtained with bipolar RFA using the internally cooled electrode was 47.5+/- 17 cm3, which was significantly less than that with bipolar RFA using perfusion-cooled electrodes (P <0.05). Bipolar RFA using perfusion-cooled electrodes achieves homogeneous areas of coagulation necrosis between two electrodes, preferably at 3 or 4 cm inter-electrode distance for 20 min, and is better in creating large coagulation necrosis than bipolar RFA using internally cooled electrodes.
Heroes and Legends Ribbon Cutting Ceremony
2016-11-11
Dignitaries, including members of the U.S. Astronaut Hall of Fame, prepare to cut a ceremonial ribbon opening the Heroes and Legends attraction at the Kennedy Space Center Visitor Complex. The new facility includes the U.S. Astronaut Hall of Fame and looks back to the pioneering efforts of Mercury, Gemini and Apollo. It sets the stage by providing the background and context for space exploration and the legendary men and women who pioneered the nation's journey into space.
Heroes and Legends Ribbon Cutting Ceremony
2016-11-11
Dignitaries, including members of the U.S. Astronaut Hall of Fame, have just cut a ceremonial ribbon opening the Heroes and Legends attraction at the Kennedy Space Center Visitor Complex. The new facility includes the U.S. Astronaut Hall of Fame and looks back to the pioneering efforts of Mercury, Gemini and Apollo. It sets the stage by providing the background and context for space exploration and the legendary men and women who pioneered the nation's journey into space.
Muro, Florida; Mtove, George; Mosha, Neema; Wangai, Hannah; Harrison, Nicole; Hildenwall, Helena; Schellenberg, David; Todd, Jim; Olomi, Raimos; Reyburn, Hugh
2015-06-01
Cough or difficult breathing and an increased respiratory rate for their age are the commonest indications for outpatient antibiotic treatment in African children. We aimed to determine whether respiratory rate was likely to be transiently raised by a number of contextual factors in a busy clinic leading to inaccurate diagnosis. Respiratory rates were recorded in children aged 2-59 months presenting with cough or difficulty breathing to one of the two busy outpatient clinics and then repeated at 10-min intervals over 1 h in a quiet setting. One hundred and sixty-seven children were enrolled with a mean age of 7.1 (SD ± 2.9) months in infants and 27.6 (SD ± 12.8) months in children aged 12-59 months. The mean respiratory rate declined from 42.3 and 33.6 breaths per minute (bpm) in the clinic to 39.1 and 32.6 bpm after 10 min in a quiet room and to 39.2 and 30.7 bpm (P < 0.001) after 60 min in younger and older children, respectively. This resulted in 11/13 (85%) infants and 2/15 (13%) older children being misclassified with non-severe pneumonia. In a random effects linear regression model, the variability in respiratory rate within children (42%) was almost as much as the variability between children (58%). Changing the respiratory rates cut-offs to higher thresholds resulted in a small reduction in the proportion of non-severe pneumonia mis-classifications in infants. Noise and other contextual factors may cause a transient increase in respiratory rate and consequently misclassification of non-severe pneumonia. However, this effect is less pronounced in older children than infants. Respiratory rate is a difficult sign to measure as the variation is large between and within children. More studies of the accuracy and utility of respiratory rate as a proxy for non-severe pneumonia diagnosis in a busy clinic are needed. © 2015 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reiner, Caecilia S., E-mail: caecilia.reiner@usz.ch; Gordic, Sonja; Puippe, Gilbert
2016-03-15
PurposeTo evaluate in patients with hepatocellular carcinoma (HCC), whether assessment of tumor heterogeneity by histogram analysis of computed tomography (CT) perfusion helps predicting response to transarterial radioembolization (TARE).Materials and MethodsSixteen patients (15 male; mean age 65 years; age range 47–80 years) with HCC underwent CT liver perfusion for treatment planning prior to TARE with Yttrium-90 microspheres. Arterial perfusion (AP) derived from CT perfusion was measured in the entire tumor volume, and heterogeneity was analyzed voxel-wise by histogram analysis. Response to TARE was evaluated on follow-up imaging (median follow-up, 129 days) based on modified Response Evaluation Criteria in Solid Tumors (mRECIST). Results of histogrammore » analysis and mean AP values of the tumor were compared between responders and non-responders. Receiver operating characteristics were calculated to determine the parameters’ ability to discriminate responders from non-responders.ResultsAccording to mRECIST, 8 patients (50 %) were responders and 8 (50 %) non-responders. Comparing responders and non-responders, the 50th and 75th percentile of AP derived from histogram analysis was significantly different [AP 43.8/54.3 vs. 27.6/34.3 mL min{sup −1} 100 mL{sup −1}); p < 0.05], while the mean AP of HCCs (43.5 vs. 27.9 mL min{sup −1} 100 mL{sup −1}; p > 0.05) was not. Further heterogeneity parameters from histogram analysis (skewness, coefficient of variation, and 25th percentile) did not differ between responders and non-responders (p > 0.05). If the cut-off for the 75th percentile was set to an AP of 37.5 mL min{sup −1} 100 mL{sup −1}, therapy response could be predicted with a sensitivity of 88 % (7/8) and specificity of 75 % (6/8).ConclusionVoxel-wise histogram analysis of pretreatment CT perfusion indicating tumor heterogeneity of HCC improves the pretreatment prediction of response to TARE.« less
NASA Astrophysics Data System (ADS)
Li, Peng; Jiang, Shengyuan; Tang, Dewei; Xu, Bo
2017-05-01
For sake of striking a balance between the need of drilling efficiency and the constrains of power budget on the moon, the penetrations per revolution of drill bit are generally limited in the range around 0.1 mm, and besides the geometric angle of the cutting blade need to be well designed. This paper introduces a simulation approach based on PFC3D (particle flow code 3 dimensions) for analyzing the cutting load feature on lunar rock simulant, which is derived from different geometric-angle blades with a small cutting depth. The mean values of the cutting force of five blades in the survey region (four on the boundary points and one on the center point) are selected as the macroscopic responses of model. The method of experimental design which includes Plackett-Burman (PB) design and central composite design (CCD) method is adopted in the matching procedure of microparameters in PFC model. Using the optimization method of enumeration, the optimum set of microparameters is acquired. Then, the experimental validation is implemented by using other twenty-five blades with different geometric angles, and the results from both simulations and laboratory tests give fair agreements. Additionally, the rock breaking process cut by different blades are quantified from simulation analysis. This research provides the theoretical support for the refinement of the rock cutting load prediction and the geometric design of cutting blade on the drill bit.
Novel and safer endoscopic cholecystectomy using only a flexible endoscope via single port
Mori, Hirohito; Kobayashi, Nobuya; Kobara, Hideki; Nishiyama, Noriko; Fujihara, Shintaro; Chiyo, Taiga; Ayaki, Maki; Nagase, Takashi; Masaki, Tsutomu
2016-01-01
AIM: To apply the laparoscopic and endoscopic cooperative surgery concept, we investigated whether endoscopic cholecystectomy could be performed more safely and rapidly via only 1 port or not. METHODS: Two dogs (11 and 13-mo-old female Beagle) were used in this study. Only 1 blunt port was created, and a flexible endoscope with a tip attachment was inserted between the fundus of gallbladder and liver. After local injection of saline to the gallbladder bed, resection of the gallbladder bed from the liver was performed. After complete resection of the gallbladder bed, the gallbladder was pulled up to resect its neck using the Ring-shaped thread technique. The neck of the gallbladder was cut using scissor forceps. Resected gallbladder was retrieved using endoscopic net forceps via a port. RESULTS: The operation times from general anesthetizing with sevoflurane to finishing the closure of the blunt port site were about 50 min and 60 min respectively. The resection times of gallbladder bed were about 15 min and 13 min respectively without liver injury and bleeding at all. Feed were given just after next day of operation, and they had a good appetite. Two dogs are in good health now and no complications for 1 mo after endoscopic cholecystectomy using only a flexible endoscope via one port. CONCLUSION: We are sure of great feasibility of endoscopic cholecystectomy via single port for human. PMID:27053847
Volume and mass distribution in selected families of asteroids
NASA Astrophysics Data System (ADS)
Wlodarczyk, I.; Leliwa-Kopystynski, J.
2014-07-01
Members of five asteroid families (Vesta, Eos, Eunomia, Koronis, and Themis) were identified using the Hierarchical Clustering Method (HCM) for a data set containing 292,003 numbered asteroids. The influence of the choice of the best value of the parameter v_{cut} that controls the distances of asteroids in the proper elements space a, e, i was investigated with a step as small as 1 m/s. Results are given in a set of figures showing the families on the planes (a, e), (a, i), (e, i). Another form for the presentation of results is related to the secular resonances in the asteroids' motion with the giant planets, mostly with Saturn. Relations among asteroid radius, albedo, and absolute magnitude allow us to calculate the volumes of individual members of an asteroid family. After summation, the volumes of the parent bodies of the families were found. This paper presents the possibility and the first results of using a combined method for asteroid family identifications based on the following items: (i) Parameter v_{cut} is established with precision as high as 1 m/s; (ii) the albedo (if available) of the potential members is considered for approving or rejecting the family membership; (iii) a color classification is used for the same purpose as well. Searching for the most reliable parameter values for the family populations was performed by means of a consecutive application of the HCM with increasing parameter v_{cut}. The results are illustrated in the figure. Increasing v_{cut} in steps as small as 1 m/s allowed to observe the computational strength of the HCM: the critical value of the parameter v_{cut} (see the breaking-points of the plots in the figure) separates the assemblage of potential family members from 'an ocean' of background asteroids that are not related to the family. The critical values of v_{cut} vary from 57 m/s for the Vesta family to 92 m/s for the Eos family. If the parameter v_{cut} surpasses its critical value, the number of HCM-discovered family members increases enormously and without any physical reason.
Effect of simethicone on the accuracy of the rapid urease test.
Ng, F H; Wong, S Y; Kng, C; Chow, S L; Lai, K C; Ng, W F
1998-10-01
Simethicone, which is a principal ingredient in the defoaming agent used during gastroscopy, can inhibit the growth of Helicobacter pylori (MIC, 64-128 mg/l). This prospective study was designed to evaluate the in vivo and in vitro effects of simethicone on the accuracy of the rapid urease test (RUT). In the in vivo study, three sets of gastric biopsies (two from the antrum, and one from the corpus) were taken from 75 patients. The first set was examined histologically, and the second set was used for the RUT (pre-simethicone RUT). Then, 25 ml simethicone (1200 mg/l) was introduced into the stomach for a contact time of 1 min. A third set of gastric biopsies was taken for the RUT (post-simethicone RUT). In the in vitro clinical study, 41 patients were recruited. The first set of gastric biopsies was used for the RUT (pre-incubation RUT). The second set was incubated in 1 ml of simethicone for 5 min before being used for the RUT (post-incubation RUT). In the spectrophotometric study, urease activity before and after incubation in simethicone for 5 min was quantified in 12 patients by measuring the absorbance at 560 nm. Reading at 15 min, the concordance rate between the pre-simethicone and post-simethicone RUT was 98%. In the in vitro clinical study, the concordance rate between the pre-incubation and post-incubation RUT was 97%. The spectophotometric study showed a significant reduction of 43% in urease activity after incubation in simethicone. The application of a defoaming agent containing simethicone does not affect the accuracy of the RUT. However, simethicone modestly suppresses urea hydrolysis.
Effects of TEA·HCl hardening accelerator on the workability of cement-based materials
NASA Astrophysics Data System (ADS)
Pan, Wenhao; Ding, Zhaoyang; Chen, Yanwen
2017-03-01
The aim of the test is to research the influence rules of TEA·HCl on the workability of cement paste and concrete. Based on the features of the new hardening accelerator, an experimental analysis system were established through different dosages of hardening accelerator, and the feasibility of such accelerator to satisfy the need of practical engineering was verified. The results show that adding of the hardening accelerator can accelerate the cement hydration, and what’s more, when the dosage was 0.04%, the setting time was the shortest while the initial setting time and final setting time were 130 min and 180 min, respectively. The initial fluidity of cement paste of adding accelerator was roughly equivalent compared with that of blank. After 30 min, fluidity loss would decrease with the dosage increasing, but fluidity may increase. The application of the hardening accelerator can make the early workability of concrete enhance, especially the slump loss of 30 min can improve more significantly. The bleeding rate of concrete significantly decreases after adding TEA·HCl. The conclusion is that the new hardening accelerator can meet the need of the workability of cement-based materials in the optimum dosage range.
Effect of rest interval length on bench press performance in boys, teens, and men.
Faigenbaum, Avery D; Ratamess, Nicholas A; McFarland, Jim; Kaczmarek, Jon; Coraggio, Michael J; Kang, Jie; Hoffman, Jay R
2008-11-01
The purpose of this study was to assess the lifting performance of boys (N = 12; age 11.3 +/- 0.8 yr), teens (N = 13; age 13.6 +/- 0.6 yr), and men (N = 17; age 21.4 +/- 2.1 yr) to various rest interval (RI) lengths on the bench press exercise. Each subject performed 3 sets with a 10 repetition maximum load and a 1, 2, and 3 min RI between sets. Significant differences in lifting performance between age groups were observed within each RI for selected sets with boys and teens performing significantly more total repetitions than adults following protocols with 1 min (27.9 +/- 3.1, 26.9 +/- 3.9, and 18.2 +/- 4.1, respectively), 2 min (29.6 +/- 1.0, 27.8 +/- 3.5, and 21.4 +/- .1, respectively) and 3 min (30.0 +/- 0.0, 28.8 +/- 2.4, and 23.9 +/- 5.3, respectively) RIs. Significant differences in average velocity and average power between age groups were also observed. These findings indicate that boys and teens are better able to maintain muscle performance during intermittent moderate-intensity resistance exercise as compared with men.
NASA Astrophysics Data System (ADS)
Adesta, Erry Yulian T.; Riza, Muhammad; Avicena
2018-03-01
Tool wear prediction plays a significant role in machining industry for proper planning and control machining parameters and optimization of cutting conditions. This paper aims to investigate the effect of tool path strategies that are contour-in and zigzag tool path strategies applied on tool wear during pocket milling process. The experiments were carried out on CNC vertical machining centre by involving PVD coated carbide inserts. Cutting speed, feed rate and depth of cut were set to vary. In an experiment with three factors at three levels, Response Surface Method (RSM) design of experiment with a standard called Central Composite Design (CCD) was employed. Results obtained indicate that tool wear increases significantly at higher range of feed per tooth compared to cutting speed and depth of cut. This result of this experimental work is then proven statistically by developing empirical model. The prediction model for the response variable of tool wear for contour-in strategy developed in this research shows a good agreement with experimental work.
Evolutionary Bi-objective Optimization for Bulldozer and Its Blade in Soil Cutting
NASA Astrophysics Data System (ADS)
Sharma, Deepak; Barakat, Nada
2018-02-01
An evolutionary optimization approach is adopted in this paper for simultaneously achieving the economic and productive soil cutting. The economic aspect is defined by minimizing the power requirement from the bulldozer, and the soil cutting is made productive by minimizing the time of soil cutting. For determining the power requirement, two force models are adopted from the literature to quantify the cutting force on the blade. Three domain-specific constraints are also proposed, which are limiting the power from the bulldozer, limiting the maximum force on the bulldozer blade and achieving the desired production rate. The bi-objective optimization problem is solved using five benchmark multi-objective evolutionary algorithms and one classical optimization technique using the ɛ-constraint method. The Pareto-optimal solutions are obtained with the knee-region. Further, the post-optimal analysis is performed on the obtained solutions to decipher relationships among the objectives and decision variables. Such relationships are later used for making guidelines for selecting the optimal set of input parameters. The obtained results are then compared with the experiment results from the literature that show a close agreement among them.
A general equation to obtain multiple cut-off scores on a test from multinomial logistic regression.
Bersabé, Rosa; Rivas, Teresa
2010-05-01
The authors derive a general equation to compute multiple cut-offs on a total test score in order to classify individuals into more than two ordinal categories. The equation is derived from the multinomial logistic regression (MLR) model, which is an extension of the binary logistic regression (BLR) model to accommodate polytomous outcome variables. From this analytical procedure, cut-off scores are established at the test score (the predictor variable) at which an individual is as likely to be in category j as in category j+1 of an ordinal outcome variable. The application of the complete procedure is illustrated by an example with data from an actual study on eating disorders. In this example, two cut-off scores on the Eating Attitudes Test (EAT-26) scores are obtained in order to classify individuals into three ordinal categories: asymptomatic, symptomatic and eating disorder. Diagnoses were made from the responses to a self-report (Q-EDD) that operationalises DSM-IV criteria for eating disorders. Alternatives to the MLR model to set multiple cut-off scores are discussed.
Heat-Assisted Machining for Material Removal Improvement
NASA Astrophysics Data System (ADS)
Mohd Hadzley, A. B.; Hafiz, S. Muhammad; Azahar, W.; Izamshah, R.; Mohd Shahir, K.; Abu, A.
2015-09-01
Heat assisted machining (HAM) is a process where an intense heat source is used to locally soften the workpiece material before machined by high speed cutting tool. In this paper, an HAM machine is developed by modification of small CNC machine with the addition of special jig to hold the heat sources in front of the machine spindle. Preliminary experiment to evaluate the capability of HAM machine to produce groove formation for slotting process was conducted. A block AISI D2 tool steel with100mm (width) × 100mm (length) × 20mm (height) size has been cut by plasma heating with different setting of arc current, feed rate and air pressure. Their effect has been analyzed based on distance of cut (DOC).Experimental results demonstrated the most significant factor that contributed to the DOC is arc current, followed by the feed rate and air pressure. HAM improves the slotting process of AISI D2 by increasing distance of cut due to initial cutting groove that formed during thermal melting and pressurized air from the heat source.
Spectroscopy of the Schwarzschild black hole at arbitrary frequencies.
Casals, Marc; Ottewill, Adrian
2012-09-14
Linear field perturbations of a black hole are described by the Green function of the wave equation that they obey. After Fourier decomposing the Green function, its two natural contributions are given by poles (quasinormal modes) and a largely unexplored branch cut in the complex frequency plane. We present new analytic methods for calculating the branch cut on a Schwarzschild black hole for arbitrary values of the frequency. The branch cut yields a power-law tail decay for late times in the response of a black hole to an initial perturbation. We determine explicitly the first three orders in the power-law and show that the branch cut also yields a new logarithmic behavior T(-2ℓ-5)lnT for late times. Before the tail sets in, the quasinormal modes dominate the black hole response. For electromagnetic perturbations, the quasinormal mode frequencies approach the branch cut at large overtone index n. We determine these frequencies up to n(-5/2) and, formally, to arbitrary order. Highly damped quasinormal modes are of particular interest in that they have been linked to quantum properties of black holes.
Participation of ethylene in gravitropism
NASA Technical Reports Server (NTRS)
Harrison, M.; Pickard, B. G.
1984-01-01
In shoots of many plants, of which tomato (Lycopersicon esculentum Mill.) is an example, ethylene production is substantially increased during gravitropism. As a first step toward elucidating the role of ethylene in gravitropism, detailed time courses of ethylene production in isolated hypocotyl segments and whole plants were measured for gravistimulated and upright tomato seedlings. In the first experiment, seedlings were set upright or laid horizontal and then, at 15 min intervals, sets of hypocotyls were excised and sealed into gas tight vials. A steady long term rise in ethylene production begins after 15 min gravistimulation. It is possible that this increase is a consequence of the accumulation of indoleacetic acid (IAA) in the lower tissue of the hypocotyle. In a second kind of experiment, whole seedlings were enclosed in sealed chambers and air samples were withdrawn at 5 min intervals. Stimulated seedlings produced more ethylene than controls during the first 5 min interval, but not appreciably more during the second. This suggests the possibility that the ethylene production induced during the first 5 min occurs immediately rather than after a lag, and thus much too soon to be controlled by redistribution of IAA.
NASA Astrophysics Data System (ADS)
Madajewski, Marek; Nowakowski, Zbigniew
2017-01-01
This paper presents analysis of flank wear influence on forces in orthogonal turning of 42CrMo4 steel and evaluates capacity of finite element model to provide such force values. Data about magnitude of feed and cutting force were obtained from measurements with force tensiometer in experimental test as well as from finite element analysis of chip formation process in ABAQUS/Explicit software. For studies an insert with complex rake face was selected and flank wear was simulated by grinding operation on its flank face. The aim of grinding inset surface was to obtain even flat wear along cutting edge, which after the measurement could be modeled with CAD program and applied in FE analysis for selected range of wear width. By comparing both sets of force values as function of flank wear in given cutting conditions FEA model was validated and it was established that it can be applied to analyze other physical aspects of machining. Force analysis found that progression of wear causes increase in cutting force magnitude and steep boost to feed force magnitude. Analysis of Fc/Ff force ratio revealed that flank wear has significant impact on resultant force in orthogonal cutting and magnitude of this force components in cutting and feed direction. Surge in force values can result in transfer of substantial loads to machine-tool interface.
Using the thermal infrared multispectral scanner (TIMS) to estimate surface thermal responses
NASA Technical Reports Server (NTRS)
Luvall, J. C.; Holbo, H. R.
1987-01-01
A series of measurements was conducted over the H.J. Andrews, Oregon, experimental coniferous forest, using airborne thermal infrared multispectral scanner (TIMS). Flight lines overlapped, with a 28-min time difference between flight lines. Concurrent radiosonde measurements of atmospheric profiles of air temperature and moisture were used for atmospheric radiance corrections of the TIMS data. Surface temperature differences over time between flight lines were used to develop thermal response numbers (TRNs) which characterized the thermal response (in KJ/sq m/C, where K is the measured incoming solar radiation) of the different surface types. The surface types included a mature forest (canopy dominated by dense crowns of Pseudosuga menziesii, with a secondary canopy of dense Tsuga heterophylla, and also a tall shrub layer of Acer circinatum) and a two-year-old clear-cut. The temperature distribution, within TIMS thermal images was found to reflect the surface type examined. The clear-cut surface had the lowest TRN, while mature Douglas fir the highest.
Ouyang, Yiwen; Li, Jingyi; Phaneuf, Christopher; Riehl, Paul S; Forest, Craig; Begley, Matthew; Haverstick, Doris M; Landers, James P
2016-01-21
This paper presents a simple and cost-effective polyester toner microchip fabricated with laser print and cut lithography (PCL) to use with a battery-powered centrifugal platform for fluid handling. The combination of the PCL microfluidic disc and centrifugal platform: (1) allows parallel aliquoting of two different reagents of four different volumes ranging from nL to μL with an accuracy comparable to a piston-driven air pipette; (2) incorporates a reciprocating mixing unit driven by a surface-tension pump for further dilution of reagents, and (3) is amenable to larger scale integration of assay multiplexing (including all valves and mixers) without substantially increasing fabrication cost and time. For a proof of principle, a 10 min colorimetric assay for the quantitation of the protein level in the human blood plasma samples is demonstrated on chip with a limit of detection of ∼5 mg mL(-1) and coefficient of variance of ∼7%.
NASA Astrophysics Data System (ADS)
Rajabifar, Bahram; Kim, Sanha; Slinker, Keith; Ehlert, Gregory J.; Hart, A. John; Maschmann, Matthew R.
2015-10-01
We demonstrate that vertically aligned carbon nanotubes (CNTs) can be precisely machined in a low pressure water vapor ambient using the electron beam of an environmental scanning electron microscope. The electron beam locally damages the irradiated regions of the CNT forest and also dissociates the water vapor molecules into reactive species including hydroxyl radicals. These species then locally oxidize the damaged region of the CNTs. The technique offers material removal capabilities ranging from selected CNTs to hundreds of cubic microns. We study how the material removal rate is influenced by the acceleration voltage, beam current, dwell time, operating pressure, and CNT orientation. Milled cuts with depths between 0-100 microns are generated, corresponding to a material removal rate of up to 20.1 μm3/min. The technique produces little carbon residue and does not disturb the native morphology of the CNT network. Finally, we demonstrate direct machining of pyramidal surfaces and re-entrant cuts to create freestanding geometries.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rajabifar, Bahram; Maschmann, Matthew R., E-mail: MaschmannM@missouri.edu; Kim, Sanha
2015-10-05
We demonstrate that vertically aligned carbon nanotubes (CNTs) can be precisely machined in a low pressure water vapor ambient using the electron beam of an environmental scanning electron microscope. The electron beam locally damages the irradiated regions of the CNT forest and also dissociates the water vapor molecules into reactive species including hydroxyl radicals. These species then locally oxidize the damaged region of the CNTs. The technique offers material removal capabilities ranging from selected CNTs to hundreds of cubic microns. We study how the material removal rate is influenced by the acceleration voltage, beam current, dwell time, operating pressure, andmore » CNT orientation. Milled cuts with depths between 0–100 microns are generated, corresponding to a material removal rate of up to 20.1 μm{sup 3}/min. The technique produces little carbon residue and does not disturb the native morphology of the CNT network. Finally, we demonstrate direct machining of pyramidal surfaces and re-entrant cuts to create freestanding geometries.« less
Identifying and Evaluating External Validity Evidence for Passing Scores
ERIC Educational Resources Information Center
Davis-Becker, Susan L.; Buckendahl, Chad W.
2013-01-01
A critical component of the standard setting process is collecting evidence to evaluate the recommended cut scores and their use for making decisions and classifying students based on test performance. Kane (1994, 2001) proposed a framework by which practitioners can identify and evaluate evidence of the results of the standard setting from (1)…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bono, M J; Hibbard, R L
2005-12-05
A tool holder was designed to facilitate the machining of precision meso-scale components with complex three-dimensional shapes with sub-{micro}m accuracy on a four-axis lathe. A four-axis lathe incorporates a rotary table that allows the cutting tool to swivel with respect to the workpiece to enable the machining of complex workpiece forms, and accurately machining complex meso-scale parts often requires that the cutting tool be aligned precisely along the axis of rotation of the rotary table. The tool holder designed in this study has greatly simplified the process of setting the tool in the correct location with sub-{micro}m precision. The toolmore » holder adjusts the tool position using flexures that were designed using finite element analyses. Two flexures adjust the lateral position of the tool to align the center of the nose of the tool with the axis of rotation of the B-axis, and another flexure adjusts the height of the tool. The flexures are driven by manual micrometer adjusters, each of which provides a minimum increment of motion of 20 nm. This tool holder has simplified the process of setting a tool with sub-{micro}m accuracy, and it has significantly reduced the time required to set a tool.« less
Influence of chewing rate on salivary stress hormone levels.
Tasaka, Akinori; Tahara, Yasuaki; Sugiyama, Tetsuya; Sakurai, Kaoru
2008-10-01
The purpose of this study was to clarify the effect of different chewing rates on salivary cortisol levels as a stress indicator. The subject group consisted of 16 healthy males. They were required to rest for 30 min, and then given arithmetic calculations to perform for 30 min as stress loading. Immediately after, the first set of saliva specimens (S1) was collected over a period of 1 min to measure cortisol levels. Next, they were asked to chew a tasteless gum base for 10 min, and the second set of saliva specimens (S2) was collected in the same manner. They were then required to rest for 10 min, after which the third set of saliva specimens (S3) was collected. Chewing rates were set to slow, habitual, and fast in time with a metronome. Salivary cortisol levels were analyzed by radioimmunoassay. Changes in salivary cortisol levels comparing S1 with S2, and S1 with S3 were determined. Changes in salivary cortisol levels between S1 and S2 showed a reduction of 4.7%, 14.6%, and 16.2% with slow, habitual, and fast chewing, respectively. A significant difference was observed between slow and fast chewing. Changes in salivary cortisol levels between S1 and S3 showed a reduction of 14.4%, 22.2%, and 25.8% with slow, habitual, and fast chewing, respectively. A significant difference was observed between slow and fast chewing. This study showed that differences in chewing rate affected salivary cortisol levels as a stress indicator, and suggested that the effect on stress release with fast chewing is greater than that with slow chewing.
el-Briak, Hasna; Durand, Denis; Nurit, Josiane; Munier, Sylvie; Pauvert, Bernard; Boudeville, Phillipe
2002-01-01
By mixing CaHPO(4) x 2H(2)O (DCPD) and CaO with water or sodium phosphate buffers as liquid phase, a calcium phosphate cement was obtained. Its physical and mechanical properties, such as compressive strength, initial and final setting times, cohesion time, dough time, swelling time, dimensional and thermal behavior, and injectability were investigated by varying different parameters such as liquid to powder (L/P) ratio (0.35-0.7 ml g(-1)), molar calcium to phosphate (Ca/P) ratio (1.67-2.5) and the pH (4, 7, and 9) and the concentration (0-1 M) of the sodium phosphate buffer. The best results were obtained with the pH 7 sodium phosphate buffer at the concentration of 0.75 M. With this liquid phase, physical and mechanical properties depended on the Ca/P and L/P ratios, varying from 3 to 11 MPa (compressive strength), 6 to 10 min (initial setting time), 11 to 15 min (final setting time), 15 to 30 min (swelling time), 7 to 20 min (time of 100% injectability). The dough or working time was over 16 min. This cement expanded during its setting (1.2-5 % according to Ca/P and L/P ratios); this would allow a tight filling. Given the mechanical and rheological properties of this new DCPD/CaO-based cement, its use as root canal sealing material can be considered as classical calcium hydroxide or ZnO/eugenol-based pastes, without or with a gutta-percha point. Copyright 2002 Wiley Periodicals, Inc. J Biomed Mater Res (Appl Biomater) 63: 447-453, 2002
Zhang, Yu; Chen, Yue-Guo
2018-03-05
To compare the incidence of rainbow glare (RG) after femtosecond laser assisted-LASIK (FS-LASIK) using the upgraded FS200 femtosecond laser with different flap cut parameter settings. A consecutive series of 129 patients (255 eyes) who underwent FS-LASIK for correcting myopia and/or astigmatism using upgraded WaveLight FS200 femtosecond laser with the original settings was included in group A. Another consecutive series of 129 patients (255 eyes) who underwent FS-LASIK using upgraded WaveLight FS200 femtosecond laser with flap cut parameter settings changed (decreased pulse energy, spot and line separation) was included in group B. The incidence and fading time of RG, confocal microscopic image and postoperative clinical results were compared between the two groups. There were no differences between the two groups in age, baseline refraction, excimer laser ablation depth, postoperative uncorrected visual acuity and refraction. The incidence rate of RG in group A (35/255, 13.73%) was significantly higher than that in group B (4/255, 1.57%) (P < 0.05). The median fading time was 3 months in group A and 1 month in group B (P > 0.05).The confocal microscopic images showed wider laser spot spacing in group A than group B. The incidence of RG was significantly correlated with age and grouping (P < 0.05). The upgraded FS200 femtosecond laser with original flap cut parameter settings could increase the incidence of RG. The narrower grating size and lower pulse energy could ameliorate this side effect.
Dheda, Keertan; Van-Zyl Smit, Richard N.; Sechi, Leonardo A.; Badri, Motasim; Meldau, Richard; Symons, Gregory; Khalfey, Hoosein; Carr, Igshaan; Maredza, Alice; Dawson, Rodney; Wainright, Helen; Whitelaw, Andrew; Bateman, Eric D.; Zumla, Alimuddin
2009-01-01
Background Current tools for the diagnosis of tuberculosis pleural effusions are sub-optimal. Data about the value of new diagnostic technologies are limited, particularly, in high burden settings. Preliminary case control studies have identified IFN-γ-inducible-10kDa protein (IP-10) as a promising diagnostic marker; however, its diagnostic utility in a day-to-day clinical setting is unclear. Detection of LAM antigen has not previously been evaluated in pleural fluid. Methods We investigated the comparative diagnostic utility of established (adenosine deaminase [ADA]), more recent (standardized nucleic-acid-amplification-test [NAAT]) and newer technologies (a standardized LAM mycobacterial antigen-detection assay and IP-10 levels) for the evaluation of pleural effusions in 78 consecutively recruited South African tuberculosis suspects. All consenting participants underwent pleural biopsy unless contra-indicated or refused. The reference standard comprised culture positivity for M. tuberculosis or histology suggestive of tuberculosis. Principal Findings Of 74 evaluable subjects 48, 7 and 19 had definite, probable and non-TB, respectively. IP-10 levels were significantly higher in TB vs non-TB participants (p<0.0001). The respective outcomes [sensitivity, specificity, PPV, NPV %] for the different diagnostic modalities were: ADA at the 30 IU/L cut-point [96; 69; 90; 85], NAAT [6; 93; 67; 28], IP-10 at the 28,170 pg/ml ROC-derived cut-point [80; 82; 91; 64], and IP-10 at the 4035 pg/ml cut-point [100; 53; 83; 100]. Thus IP-10, using the ROC-derived cut-point, missed ∼20% of TB cases and mis-diagnosed ∼20% of non-TB cases. By contrast, when a lower cut-point was used a negative test excluded TB. The NAAT had a poor sensitivity but high specificity. LAM antigen-detection was not diagnostically useful. Conclusion Although IP-10, like ADA, has sub-optimal specificity, it may be a clinically useful rule-out test for tuberculous pleural effusions. Larger multi-centric studies are now required to confirm our findings. PMID:19277111
Sacre, J W; Jellis, C L; Coombes, J S; Marwick, T H
2012-09-01
Poor prognosis associated with blunted post-exercise heart-rate recovery may reflect autonomic dysfunction. This study sought the accuracy of post-exercise heart-rate recovery in the diagnosis of cardiac autonomic neuropathy, which represents a serious, but often unrecognized complication of Type 2 diabetes. Clinical assessment of cardiac autonomic neuropathy and maximal treadmill exercise testing for heart-rate recovery were performed in 135 patients with Type 2 diabetes and negative exercise echocardiograms. Cardiac autonomic neuropathy was defined by abnormalities in ≥ 2 of 7 autonomic function markers, including four cardiac reflex tests and three indices of short-term (5-min) heart-rate variability. Heart-rate recovery was defined at 1-, 2- and 3-min post-exercise. Patients with cardiac autonomic neuropathy (n = 27; 20%) had lower heart-rate recovery at 1-, 2- and 3-min post-exercise (P < 0.01). Heart-rate recovery demonstrated univariate associations with autonomic function markers (r-values 0.20-0.46, P < 0.05). Area under the receiver-operating characteristic curve revealed good diagnostic performance of all heart-rate recovery parameters (range 0.80-0.83, P < 0.001). Optimal cut-offs for heart-rate recovery at 1-, 2- and 3-min post-exercise were ≤ 28 beats/min (sensitivity 93%, specificity 69%), ≤ 50 beats/min (sensitivity 96%, specificity 63%) and ≤ 52 beats/min (sensitivity 70%, specificity 84%), respectively. These criteria predicted cardiac autonomic neuropathy independently of relevant clinical and exercise test information (adjusted odds ratios 7-28, P < 0.05). Post-exercise heart-rate recovery provides an accurate diagnostic test for cardiac autonomic neuropathy in Type 2 diabetes. The high sensitivity and modest specificity suggests heart-rate recovery may be useful to screen for patients requiring clinical autonomic evaluation. © 2012 The Authors. Diabetic Medicine © 2012 Diabetes UK.
An Investigation for Disposal of Drill Cuttings into Unconsolidated Sandstones and Clayey Sands
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mese, Ali; Dvorkin, Jack; Shillinglaw, John
2000-09-11
This project include experimental data and a set of models for relating elastic moduli/porosity/texture and static-to-dynamic moduli to strength and failure relationships for unconsolidated sands and clayey sands. The results of the project should provide the industry with a basis for wider use of oil base drilling fluids in water sensitive formations by implementing drill cutting injection into existing wells at abandoned formations and controlling fracture geometry to prevent ground water contamination.
Heroes and Legends Ribbon Cutting Ceremony
2016-11-11
Fireworks are launched as dignitaries, including members of the U.S. Astronaut Hall of Fame, have just cut a ceremonial ribbon opening the Heroes and Legends attraction at the Kennedy Space Center Visitor Complex. The new facility includes the U.S. Astronaut Hall of Fame and looks back to the pioneering efforts of Mercury, Gemini and Apollo. It sets the stage by providing the background and context for space exploration and the legendary men and women who pioneered the nation's journey into space.
Effects of Dissipation on a Superconducting Single Electron Transistor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kycia, J. B.; Chen, J.; Therrien, R.
2001-07-02
We measure the effect of dissipation on the minimum zero-bias conductance, G{sup min}{sub 0} , of a superconducting single electron transistor (sSET) capacitively coupled to a two-dimensional electron gas (2DEG) in a GaAs/AlGaAs heterostructure. Depleting the 2DEG with a back gate voltage decreases the dissipation experienced by the sSET in situ. We find that G{sup min}{sub 0} increases as the dissipation is increased or the temperature is reduced; the functional forms of these dependences are compared with the model of Wilhelm etal.in which the leads coupled to the sSET are represented by lossy transmission lines.
Integrated Robot Task and Motion Planning in the Now
2012-06-29
so that it can effectively achieve its goals? 1 Figure 1: Simulated apartment environment with pans, cups, sink, stove, and furniture . We propose a...s. We also use s[o].min and s[o]. max to name the left and right edges of the object (loc is the same as min). 2.3 Fluents A fluent is a condition...s) := (r.min ≤ s[o].min + δ) & (r.max ≥ s[o]. max − δ) . • ClearX (r, x): region r is clear, except for exceptions, x, which is a set of objects
The critical wave speed for the Fisher Kolmogorov Petrowskii Piscounov equation with cut-off
NASA Astrophysics Data System (ADS)
Dumortier, Freddy; Popovic, Nikola; Kaper, Tasso J.
2007-04-01
The Fisher-Kolmogorov-Petrowskii-Piscounov (FKPP) equation with cut-off was introduced in (Brunet and Derrida 1997 Shift in the velocity of a front due to a cut-off Phys. Rev. E 56 2597-604) to model N-particle systems in which concentrations less than ɛ = 1/N are not attainable. It was conjectured that the cut-off function, which sets the reaction terms to zero if the concentration is below the small threshold ɛ, introduces a substantial shift in the propagation speed of the corresponding travelling waves. In this paper, we prove the conjecture of Brunet and Derrida, showing that the speed of propagation is given by c_crit(\\varepsilon)=2-{\\pi^2}/{(\\ln\\varepsilon)^2}+\\cal{O}((\\ln\\varepsilon)^{-3}) , as ɛ → 0, for a large class of cut-off functions. Moreover, we extend this result to a more general family of scalar reaction-diffusion equations with cut-off. The main mathematical techniques used in our proof are the geometric singular perturbation theory and the blow-up method, which lead naturally to the identification of the reasons for the logarithmic dependence of ccrit on ɛ as well as for the universality of the corresponding leading-order coefficient (π2).
Peng, Fang; Chen, Jun; Wang, Xia; Xu, Changqing; Liu, Tongning; Xu, Rong
2016-07-01
We investigated the effect of steaming time on Cistanche deserticola Y. C. MA slices by analyzing levels of bioactive compounds, antioxidant activity, and weight loss compared with fresh, directly oven-dried, and blanched samples. Fresh samples had extremely low levels of phenylethanoid glycosides and antioxidant activity. Lower levels of weight loss and higher amounts of soluble sugars, polysaccharides, and dilute ethanol-soluble extracts were found when the slices were steamed rather than blanched. Slices steamed for 5 and 7 min contained significantly (p<0.05) higher amounts of acteoside, isoacteoside, and 2'-acetylacteoside than directly oven-dried samples. However, soluble sugars and dilute ethanol-soluble extracts decreased gradually throughout the steaming process. The concentration of polysaccharides fluctuated during the steaming process. The steaming time had a consistent effect on antioxidant properties evaluated by oxygen radical absorbance capacity (ORAC), 2,2-diphenyl-1-picrylhydrazyl free radical scavenging activity (DPPH) and ferric reducing antioxidant property (FRAP), showing a significant increase and reaching 108.62, 23.08, and 11.68 micromoles Trolox per mass of fresh slice (μmol TE/g FW), respectively. The present results suggest that fresh-cut C. deserticola can be subjected to approximately 5-7 min of steaming to improve phenylethanoid glycoside levels and antioxidant activity, while still preserving the amounts of soluble sugars, polysaccharides, and dilute ethanol-soluble extracts. These results would help to improve the production process for fresh-cut Chinese medicines, and increase the understanding of their associated health benefits.
Texturization of as-cut p-type monocrystalline silicon wafer using different wet chemical solutions
NASA Astrophysics Data System (ADS)
Hashmi, Galib; Hasanuzzaman, Muhammad; Basher, Mohammad Khairul; Hoq, Mahbubul; Rahman, Md. Habibur
2018-06-01
Implementing texturization process on the monocrystalline silicon substrate reduces reflection and enhances light absorption of the substrate. Thus texturization is one of the key elements to increase the efficiency of solar cell. Considering as-cut monocrystalline silicon wafer as base substrate, in this work different concentrations of Na2CO3 and NaHCO3 solution, KOH-IPA (isopropyl alcohol) solution and tetramethylammonium hydroxide solution with different time intervals have been investigated for texturization process. Furthermore, saw damage removal process was conducted with 10% NaOH solution, 20 wt% KOH-13.33 wt% IPA solution and HF/nitric/acetic acid solution. The surface morphology of saw damage, saw damage removed surface and textured wafer were observed using optical microscope and field emission scanning electron microscopy. Texturization causes pyramidal micro structures on the surface of (100) oriented monocrystalline silicon wafer. The height of the pyramid on the silicon surface varies from 1.5 to 3.2 µm and the inclined planes of the pyramids are acute angle. Contact angle value indicates that the textured wafer's surface fall in between near-hydrophobic to hydrophobic range. With respect to base material absolute reflectance 1.049-0.75% within 250-800 nm wavelength region, 0.1-0.026% has been achieved within the same wavelength region when textured with 0.76 wt% KOH-4 wt% IPA solution for 20 min. Furthermore, an alternative route of using 1 wt% Na2CO3-0.2 wt% NaHCO3 solution for 50 min has been exploited in the texturization process.
Acute Responses to Resistance and High-Intensity Interval Training in Early Adolescents.
Harris, Nigel K; Dulson, Deborah K; Logan, Greig R M; Warbrick, Isaac B; Merien, Fabrice L R; Lubans, David R
2017-05-01
Harris, NK, Dulson, DK, Logan, GRM, Warbrick, IB, Merien, FLR, and Lubans, DR. Acute responses to resistance and high-intensity interval training in early adolescents. J Strength Cond Res 31(5): 1177-1186, 2017-The purpose of this study was to compare the acute physiological responses within and between resistance training (RT) and high-intensity interval training (HIIT) matched for time and with comparable effort, in a school setting. Seventeen early adolescents (12.9 ± 0.3 years) performed both RT (2-5 repetitions perceived short of failure at the end of each set) and HIIT (90% of age-predicted maximum heart rate), equated for total work set and recovery period durations comprising of 12 "sets" of 30-second work followed by 30-second recovery (total session time 12 minutes). Variables of interest included oxygen consumption, set and session heart rate (HR), and rate of perceived exertion, and change in salivary cortisol (SC), salivary alpha amylase, and blood lactate (BL) from presession to postsession. Analyses were conducted to determine responses within and between the 2 different protocols. For both RT and HIIT, there were very large increases pretrial to posttrial for SC and BL, and only BL increased greater in HIIT (9.1 ± 2.6 mmol·L) than RT (6.8 ± 3.3 mmol·L). Mean set HR for both RT (170 ± 9.1 b·min) and HIIT (179 ± 5.6 b·min) was at least 85% of HRmax. V[Combining Dot Above]O2 over all 12 sets was greater for HIIT (33.8 ± 5.21 ml·kg·min) than RT (24.9 ± 3.23 ml·kg·min). Brief, repetitive, intermittent forays into high but not supramaximal intensity exercise using RT or HIIT seemed to be a potent physiological stimulus in adolescents.
Factors affecting the appearance of the hump charge movement component in frog cut twitch fibers.
Hui, C S
1991-08-01
Charge movement was measured in frog cut twitch fibers with the double Vaseline gap technique. Five manipulations listed below were applied to investigate their effects on the hump component (I gamma) in the ON segments of TEST minus CONTROL current traces. When external Cl-1 was replaced by MeSO3- to eliminate Cl current, I gamma peaked earlier due to a few millivolts shift of the voltage dependence of I gamma kinetics in the negative direction. The Q-V plots in the TEA.Cl and TEA.MeSO3 solutions were well fitted by a sum of two Boltzmann distribution functions. The more steeply voltage-dependent component (Q gamma) had a V approximately 6 mV more negative in the TEA.MeSO3 solution than in the TEA.Cl solution. These voltage shifts were partially reversible. When creatine phosphate in the end pool solution was removed, the I gamma hump disappeared slowly over the course of 20-30 min, partly due to a suppression of Q gamma. The hump reappeared when creatine phosphate was restored. When 0.2-1.0 mM Cd2+ was added to the center pool solution to block inward Ca current, the I gamma hump became less prominent due to a prolongation in the time course of I gamma but not to a suppression of Q gamma. When the holding potential was changed from -90 to -120 mV, the amplitude of I beta was increased, thereby obscuring the I gamma hump. Finally, when a cut fiber was stimulated repetitively, I gamma lost its hump appearance because its time course was prolonged. In an extreme case, a 5-min resting interval was insufficient for a complete recovery of the waveform. In general, a stimulation rate of once per minute had a negligible effect on the shape of I gamma. Of the five manipulations, MeSO3- has the least perturbation on the appearance of I gamma and is potentially a better substitute for Cl- than SO2-(4) in eliminating Cl current if the appearance of the I gamma hump is to be preserved.
Lytic bacteriophages reduce Escherichia coli O157
Ferguson, Sean; Roberts, Cheryl; Handy, Eric; Sharma, Manan
2013-01-01
The role of lytic bacteriophages in preventing cross contamination of produce has not been evaluated. A cocktail of three lytic phages specific for E. coli O157:H7 (EcoShield™) or a control (phosphate buffered saline, PBS) was applied to lettuce by either; (1) immersion of lettuce in 500 ml of EcoShield™ 8.3 log PFU/ml or 9.8 log PFU/ml for up to 2 min before inoculation with E. coli O157:H7; (2) spray-application of EcoShield™ (9.3 log PFU/ml) to lettuce after inoculation with E. coli O157:H7 (4.10 CFU/cm2) following exposure to 50 μg/ml chlorine for 30 sec. After immersion studies, lettuce was spot-inoculated with E. coli O157:H7 (2.38 CFU/cm2). Phage-treated, inoculated lettuce pieces were stored at 4°C for and analyzed for E. coli O157:H7 populations for up to 7 d. Immersion of lettuce in 9.8 log PFU/ml EcoShield™ for 2 min significantly (p < 0.05) reduced E. coli O157:H7 populations after 24 h when stored at 4°C compared with controls. Immersion of lettuce in suspensions containing high concentrations of EcoShield™ (9.8 log PFU/ml) resulted in the deposition of high concentrations (7.8 log log PFU/cm2) of bacteriophages on the surface of fresh cut lettuce, potentially contributing to the efficacy of the lytic phages on lettuce. Spraying phages on to inoculated fresh cut lettuce after being washed in hypochlorite solution was significantly more effective in reducing E. coli O157:H7 populations (2.22 log CFU/cm2) on day 0 compared with control treatments (4.10 log CFU/cm2). Both immersion and spray treatments provided protection from E. coli O157:H7 contamination on lettuce, but spray application of lytic bacteriophages to lettuce was more effective in immediately reducing E. coli O157:H7 populations fresh cut lettuce. PMID:23819106
Cardiopulmonary resuscitation duration and survival in out-of-hospital cardiac arrest patients.
Adnet, Frederic; Triba, Mohamed N; Borron, Stephen W; Lapostolle, Frederic; Hubert, Hervé; Gueugniaud, Pierre-Yves; Escutnaire, Josephine; Guenin, Aurelien; Hoogvorst, Astrid; Marbeuf-Gueye, Carol; Reuter, Paul-Georges; Javaud, Nicolas; Vicaut, Eric; Chevret, Sylvie
2017-02-01
Relationship between cardiopulmonary arrest and resuscitation (CPR) durations and survival after out-of-hospital cardiac arrest (OHCA) remain unclear. Our primary aim was to determine the association between survival without neurologic sequelae and cardiac arrest intervals in the setting of witnessed OHCA. We analyzed 27,301 non-traumatic, witnessed OHCA patients in France included in the national registry from June 1, 2011 through December 1, 2015. We analyzed cardiac arrest intervals, designated as no-flow (NF; from collapse to start of CPR) and low-flow (LF; from start of CPR to cessation of resuscitation) in relation to 30-day survival without sequelae. We determined the influence of recognized prognostic factors (age, gender, initial rhythm, location of cardiac arrest) on this relation. For the entire cohort, the area delimited by a value of NF greater than 12min (95% confidence interval: 11-13min) and LF greater than 33min (95% confidence interval: 29-45min), yielded a probability of 30-day survival of less than 1%. These sets of values were greatly influenced by initial cardiac arrest rhythm, age, sex and location of cardiac arrest. Extended CPR duration (greater than 40min) in the setting of initial shockable cardiac rhythm is associated with greater than 1% survival with NF less than 18min. The NF interval was highly influential on the LF interval regardless of outcome, whether return of spontaneous circulation (p<0.001) or death (p<0.001). NF duration must be considered in determining CPR duration in OHCA patients. The knowledge of (NF, LF) curves as function of age, initial rhythm, location of cardiac arrest or gender may aid in decision-making vis-à-vis the termination of CPR or employment of advanced techniques. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
McCracken, M M; Morrill, K M; Fordyce, A L; Tyler, H D
2017-10-01
Previous data have demonstrated that refractometers can be used to estimate serum IgG, and that a cut-point of 7.8% Brix should be used to identify failure of passive transfer (FPT) in 1-d-old Holstein calves. The objective of the present study was to validate the use of refractometry to estimate serum IgG concentrations and evaluate FPT in Jersey calves. Blood samples (n = 97) were obtained from 1- to 3-d-old Jersey calves and centrifuged at 3,300 × g for 20 min at 25°C. Serum was analyzed for % Brix, total protein (TP), and refractive index (nD) using a Sper Scientific Digital Refractometer (model #300036, Sper Scientific, Scottsdale, AZ) within 12 h of sampling. Samples were then frozen and later analyzed in the laboratory for IgG by radial immunodiffusion. The mean serum IgG concentration for all calves was 23.7 mg/mL (SD = 12.5), with a range of 2.3 to 65.5 mg/mL. Mean serum % Brix was 8.9 (SD = 1.1; range 6.5 to 12.0). Serum % Brix was moderately correlated with IgG concentration (r = 0.77). Total protein and IgG were moderately correlated (r = 0.790). Regression was used to determine cut-points for approximately 10, 12, and 14 mg of IgG/mL and to determine the sensitivity and specificity of refractometry to identify FPT (serum IgG <10 mg/mL at 24 h of life). Brix cut-points analyzed were 7.1, 7.3, and 7.6%; TP cut-points were 4.6, 5.0, and 5.5 g/dL; and nD cut-points were 1.34332, 1.34271, and 1.3448, respectively, for 10, 12, and 14 mg of IgG/mL. The 7.3% Brix and 4.6 g/dL TP cut-points resulted in the greatest percentage of samples being correctly classified. These data suggest that digital refractometry is an acceptable and rapid method to estimate immunoglobulin G in Jersey calf serum. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Engineered Surface Properties of Porous Tungsten from Cryogenic Machining
NASA Astrophysics Data System (ADS)
Schoop, Julius Malte
Porous tungsten is used to manufacture dispenser cathodes due to it refractory properties. Surface porosity is critical to functional performance of dispenser cathodes because it allows for an impregnated ceramic compound to migrate to the emitting surface, lowering its work function. Likewise, surface roughness is important because it is necessary to ensure uniform wetting of the molten impregnate during high temperature service. Current industry practice to achieve surface roughness and surface porosity requirements involves the use of a plastic infiltrant during machining. After machining, the infiltrant is baked and the cathode pellet is impregnated. In this context, cryogenic machining is investigated as a substitutionary process for the current plastic infiltration process. Along with significant reductions in cycle time and resource use, surface quality of cryogenically machined un-infiltrated (as-sintered) porous tungsten has been shown to significantly outperform dry machining. The present study is focused on examining the relationship between machining parameters and cooling condition on the as-machined surface integrity of porous tungsten. The effects of cryogenic pre-cooling, rake angle, cutting speed, depth of cut and feed are all taken into consideration with respect to machining-induced surface morphology. Cermet and Polycrystalline diamond (PCD) cutting tools are used to develop high performance cryogenic machining of porous tungsten. Dry and pre-heated machining were investigated as a means to allow for ductile mode machining, yet severe tool-wear and undesirable smearing limited the feasibility of these approaches. By using modified PCD cutting tools, high speed machining of porous tungsten at cutting speeds up to 400 m/min is achieved for the first time. Beyond a critical speed, brittle fracture and built-up edge are eliminated as the result of a brittle to ductile transition. A model of critical chip thickness ( hc ) effects based on cutting force, temperature and surface roughness data is developed and used to study the deformation mechanisms of porous tungsten under different machining conditions. It is found that when hmax = hc, ductile mode machining of otherwise highly brittle porous tungsten is possible. The value of hc is approximately the same as the average ligament size of the 80% density porous tungsten workpiece.
Wilson, Alexander H; Kidd, Andrew C; Skinner, Jane; Musonda, Patrick; Pai, Yogish; Lunt, Claire J; Butchart, Catherine; Soiza, Roy L; Potter, John F; Myint, Phyo Kyaw
2014-05-01
the mortality is high in acutely ill oldest old patients. Understanding the prognostic factors which influence mortality will help clinicians make appropriate management decisions. we analysed prospective mortality audit data (November 2008 to January 2009) to identify variables associated with in-patient mortality in oldest old. We selected those with P < 0.10 from univariate analysis and determined at which cut-point they served as the strongest predictor of mortality. Using these cut-off points, we constructed multivariate logistic regression models. A 5-point score was derived from cut-off points which were significantly associated with mortality tested in a smaller independent re-audit sample conducted in October 2011. a total of 405 patients (mean 93.5 ± 2.7 years) were included in the study. The mean length of stay was 18.5 ± 42.4 days and 13.8% died as in-patients. Variables (cut-off values) found to be significantly associated with in-patient mortality were admission sodium (>145 mmol/l), urea (≥14 mmol/l), respiratory rate (>20/min) and shock index (>1.0): creating a 5-point score (NaURSE: NaURS in the Elderly). The crude mortality rates were 9.5, 19.9, 34.4, 66.7, and 100% for scores 0, 1, 2, 3 and 4, respectively. Using the cut-off point of ≥2, the NaURSE score has a specificity of 87% (83.1-90.3) and sensitivity of 39% (28.5-50.0), with an AUC value of 0.69 (0.63-0.76). An external independent validation study (n = 121) showed similar results. the NaURSE score may be particularly useful in identifying oldest old who are likely to die in that admission to guide appropriate care.
Proficiency Standards and Cut-Scores for Language Proficiency Tests.
ERIC Educational Resources Information Center
Moy, Raymond H.
The problem of standard setting on language proficiency tests is often approached by the use of norms derived from the group being tested, a process commonly known as "grading on the curve." One particular problem with this ad hoc method of standard setting is that it will usually result in a fluctuating standard dependent on the particular group…
ERIC Educational Resources Information Center
Stringer, Neil Simon
2012-01-01
General Certificate of Secondary Education (GCSE) and General Certificate of Education (GCE) grading standards are determined by Awarding Bodies using procedures that adhere to the Code of Practice published by the regulator, Ofqual. Grade boundary marks (cut scores) are set using subject experts' (senior examiners) judgement of the quality of…
An Application of Multifaceted Rasch Measurement in the Yes/No Angoff Standard Setting Procedure
ERIC Educational Resources Information Center
Hsieh, Mingchuan
2013-01-01
When implementing standard setting procedures, there are two major concerns: variance between panelists and efficiency in conducting multiple rounds of judgments. With regard to the former, there is concern over the consistency of the cutoff scores made by different panelists. If the cut scores show an inordinately wide range then further rounds…
A Primer-Test Centered Equating Method for Setting Cut-Off Scores
ERIC Educational Resources Information Center
Zhu, Weimo; Plowman, Sharon Ann; Park, Youngsik
2010-01-01
This study evaluated the use of a new primary field test method based on test equating to address inconsistent classification among field tests. We analyzed students' information on the Progressive Aerobic Cardiovascular Endurance Run (PACER), mile run (MR), and VO[subscript 2]max from three data sets (college: n = 94; middle school: n = 39;…
Modelling Sawing of Metal Tubes Through FEM Simulation
NASA Astrophysics Data System (ADS)
Bort, C. M. Giorgio; Bosetti, P.; Bruschi, S.
2011-05-01
The paper presents the development of a numerical model of the sawing process of AISI 304 thin tubes, which is cut through a circular blade with alternating roughing and finishing teeth. The numerical simulation environment is the three-dimensional FEM software Deform™ v.10.1. The teeth actual trajectories were determined by a blade kinematics analysis developed in Matlab™. Due to the manufacturing rolling steps and subsequent welding stage, the tube material is characterized by a gradient of properties along its thickness. Consequently, a simplified cutting test was set up and carried out in order to identify the values of relevant material parameters to be used in the numerical model. The dedicated test was the Orthogonal Tube Cutting test (OTC), which was performed on an instrumented lathe. The proposed numerical model was validated by comparing numerical results and experimental data obtained from sawing tests carried out on an industrial machine. The following outputs were compared: the cutting force, the chip thickness, and the chip contact area.
Approximate ground states of the random-field Potts model from graph cuts
NASA Astrophysics Data System (ADS)
Kumar, Manoj; Kumar, Ravinder; Weigel, Martin; Banerjee, Varsha; Janke, Wolfhard; Puri, Sanjay
2018-05-01
While the ground-state problem for the random-field Ising model is polynomial, and can be solved using a number of well-known algorithms for maximum flow or graph cut, the analog random-field Potts model corresponds to a multiterminal flow problem that is known to be NP-hard. Hence an efficient exact algorithm is very unlikely to exist. As we show here, it is nevertheless possible to use an embedding of binary degrees of freedom into the Potts spins in combination with graph-cut methods to solve the corresponding ground-state problem approximately in polynomial time. We benchmark this heuristic algorithm using a set of quasiexact ground states found for small systems from long parallel tempering runs. For a not-too-large number q of Potts states, the method based on graph cuts finds the same solutions in a fraction of the time. We employ the new technique to analyze the breakup length of the random-field Potts model in two dimensions.
Maintaining knife sharpness in industrial meat cutting: A matter of knife or meat cutter ability.
Karltun, J; Vogel, K; Bergstrand, M; Eklund, J
2016-09-01
Knife sharpness is imperative in meat cutting. The aim of this study was to compare the impact of knife blade steel quality with meat cutters' individual ability to maintain the cutting edge sharp in an industrial production setting. Twelve meat cutters in two different companies using three different knives during normal production were studied in this quasi-experimental study. Methods included were measuring knife cutting force before and after knife use, time knives were used, ratings of sharpness and discomfort and interviews. Results showed that the meat cutters' skill of maintaining sharpness during work had a much larger effect on knife sharpness during work than the knife steel differences. The ability was also related to feelings of discomfort and to physical exertion. It was found that meat cutters using more knives were more likely to suffer from discomfort in the upper limbs, which is a risk for developing MSD. Copyright © 2016 Elsevier Ltd. All rights reserved.