  1. Comparison of myocardial perfusion imaging between the new high-speed gamma camera and the standard anger camera.

    PubMed

    Tanaka, Hirokazu; Chikamori, Taishiro; Hida, Satoshi; Uchida, Kenji; Igarashi, Yuko; Yokoyama, Tsuyoshi; Takahashi, Masaki; Shiba, Chie; Yoshimura, Mana; Tokuuye, Koichi; Yamashina, Akira

    2013-01-01

    Cadmium-zinc-telluride (CZT) solid-state detectors have been recently introduced into the field of myocardial perfusion imaging. The aim of this study was to prospectively compare the diagnostic performance of the CZT high-speed gamma camera (Discovery NM 530c) with that of the standard 3-head gamma camera in the same group of patients. The study group consisted of 150 consecutive patients who underwent a 1-day stress-rest (99m)Tc-sestamibi or tetrofosmin imaging protocol. Image acquisition was performed first on a standard gamma camera with a 15-min scan time each for stress and for rest. All scans were immediately repeated on a CZT camera with a 5-min scan time for stress and a 3-min scan time for rest, using list mode. The correlations between the CZT camera and the standard camera for perfusion and function analyses were strong within narrow Bland-Altman limits of agreement. Using list mode analysis, image quality for stress was rated as good or excellent in 97% of the 3-min scans, and in 100% of the ≥4-min scans. For CZT scans at rest, similarly, image quality was rated as good or excellent in 94% of the 1-min scans, and in 100% of the ≥2-min scans. The novel CZT camera provides excellent image quality, which is equivalent to standard myocardial single-photon emission computed tomography, despite a short scan time of less than half of the standard time.

  2. Correcting (18)F-fluoride PET static scan measurements of skeletal plasma clearance for tracer efflux from bone.

    PubMed

    Siddique, Musib; Frost, Michelle L; Moore, Amelia E B; Fogelman, Ignac; Blake, Glen M

    2014-03-01

    The aim of the study was to examine whether (18)F-fluoride PET ((18)F-PET) static scan measurements of bone plasma clearance (Ki) can be corrected for tracer efflux from bone from the time of injection. The efflux of tracer from bone mineral to plasma was described by a first-order rate constant kloss. A modified Patlak analysis was applied to 60-min dynamic (18)F-PET scans of the spine and hip acquired during trials on the bone anabolic agent teriparatide to find the best-fit values of kloss at the lumbar spine, total hip and femoral shaft. The resulting values of kloss were used to extrapolate the modified Patlak plots to 120 min after injection and derive a sequence of static scan estimates of Ki at 4-min intervals that were compared with the Patlak Ki values from the 60-min dynamic scans. A comparison was made with the results of the standard static scan analysis, which assumes kloss=0. The best-fit values of kloss for the spine and hip regions of interest averaged 0.006/min and did not change when patients were treated with teriparatide. Static scan values of Ki calculated using the modified analysis with kloss=0.006/min were independent of time between 10 and 120 min after injection and were in close agreement with findings from the dynamic scans. In contrast, by 2 h after injection the static scan Ki values calculated using the standard analysis underestimated the dynamic scan results by 20%. Using a modified analysis that corrects for F efflux from bone, estimates of Ki from static PET scans can be corrected for time up to 2 h after injection. This simplified approach may obviate the need to perform dynamic scans and hence shorten the scanning procedure for the patient and reduce the cost of studies. It also enables reliable estimates of Ki to be obtained from multiple skeletal sites with a single injection of tracer.

  3. 4D spiral imaging of flows in stenotic phantoms and subjects with aortic stenosis.

    PubMed

    Negahdar, M J; Kadbi, Mo; Kendrick, Michael; Stoddard, Marcus F; Amini, Amir A

    2016-03-01

    The utility of four-dimensional (4D) spiral flow in imaging of stenotic flows in both phantoms and human subjects with aortic stenosis is investigated. The method performs 4D flow acquisitions through a stack of interleaved spiral k-space readouts. Relative to conventional 4D flow, which performs Cartesian readout, the method has reduced echo time. Thus, reduced flow artifacts are observed when imaging high-speed stenotic flows. Four-dimensional spiral flow also provides significant savings in scan times relative to conventional 4D flow. In vitro experiments were performed under both steady and pulsatile flows in a phantom model of severe stenosis (one inch diameter at the inlet, with 87% area reduction at the throat of the stenosis) while imaging a 6-cm axial extent of the phantom, which included the Gaussian-shaped stenotic narrowing. In all cases, gradient strength and slew rate for standard clinical acquisitions, and identical field of view and resolution were used. For low steady flow rates, quantitative and qualitative results showed a similar level of accuracy between 4D spiral flow (echo time [TE] = 2 ms, scan time = 40 s) and conventional 4D flow (TE = 3.6 ms, scan time = 1:01 min). However, in the case of high steady flow rates, 4D spiral flow (TE = 1.57 ms, scan time = 38 s) showed better visualization and accuracy as compared to conventional 4D flow (TE = 3.2 ms, scan time = 51 s). At low pulsatile flow rates, a good agreement was observed between 4D spiral flow (TE = 2 ms, scan time = 10:26 min) and conventional 4D flow (TE = 3.6 ms, scan time = 14:20 min). However, in the case of high flow-rate pulsatile flows, 4D spiral flow (TE = 1.57 ms, scan time = 10:26 min) demonstrated better visualization as compared to conventional 4D flow (TE = 3.2 ms, scan time = 14:20 min). The feasibility of 4D spiral flow was also investigated in five normal volunteers and four subjects with mild-to-moderate aortic stenosis. The approach achieved TE = 1.68 ms and scan time = 3:44 min. The conventional sequence achieved TE = 2.9 ms and scan time = 5:23 min. In subjects with aortic stenosis, we also compared both MRI methods with Doppler ultrasound (US) in the measurement of peak velocity, time to peak systolic velocity, and eject time. Bland-Altman analysis revealed that, when comparing peak velocities, the discrepancy between Doppler US and 4D spiral flow was significantly less than the discrepancy between Doppler and 4D Cartesian flow (2.75 cm/s vs. 10.25 cm/s), whereas the two MR methods were comparable (-5.75 s vs. -6 s) for time to peak. However, for the estimation of eject time, relative to Doppler US, the discrepancy for 4D conventional flow was smaller than that of 4D spiral flow (-16.25 s vs. -20 s). Relative to conventional 4D flow, 4D spiral flow achieves substantial reductions in both the TE and scan times; therefore, utility for it should be sought in a variety of in vivo and complex flow imaging applications. © 2015 Wiley Periodicals, Inc.

  4. Effect of live music therapy for patients undergoing magnetic resonance imaging.

    PubMed

    Walworth, Darcy D

    2010-01-01

    The purpose of the current study was to identify the effects of live music therapy interventions compared with preferred recorded music for patients undergoing MRI scans. To date, there has not been a published study involving the use of live music therapy during MRI scans. The current study investigated the differences between teenage through adult patients receiving live music therapy intervention during outpatient MRI scans versus the standard protocol of care listening to recorded music (N = 88). Subjects ranged in age from 15 to 93 years old. Results indicated subjects who received the live music therapy protocol reported significantly better perception of the MRI procedure (p < 0.05). Additionally, subjects receiving the live music therapy protocol had fewer scans repeated due to movement. Of the repeated images, 26% occurred in the live music group and 73% occurred in the recorded music group. Subjects receiving live music therapy also requested less breaks from the scan. Two percent of the live music subjects requested a break and 17.6% of the control patients requested breaks. When comparing the same type of scan between groups, subjects receiving the live music protocol required less time to complete the scans. For lumbar scans without contrast (N = 14, n = 7, n = 7), live music subjects spent an average of 4.63 less min per scan for a total of 32 less min for 7 subjects. For brain scans (N = 8, n = 4, n = 4), live music subjects spent an average of 5.8 less min per scan for a total of 23 less min for 4 subjects. Results of the current study supports the use of live music therapy intervention for teenage and adult patients undergoing MRI scans to reduce patient anxiety and improve patient perception of the scan experience. Additionally, live music therapy has the potential to shorten the length of time required for patients to complete MRI scans due to decreased patient movements and fewer breaks requested during the scans. The cost savings impact of reduced procedure time can positively impact the facility productivity by allowing more scans to be scheduled daily.

  5. Decreasing Medication Turnaround Time with Digital Scanning Technology in a Canadian Health Region

    PubMed Central

    Neville, Heather; Nodwell, Lisa; Alsharif, Sahar

    2014-01-01

    Background: Reducing medication turnaround time can improve efficiency, patient safety, and quality of care in the hospital setting. Digital scanning technology (DST) can be used to electronically transmit scanned prescriber orders to a pharmacy computer queue for verification and processing, which may help to improve medication turnaround time. Objectives: To evaluate medication turnaround time before and after implementation of DST for all medications and for antibiotics only. Methods: Medication turnaround times were evaluated retrospectively for periods before (June 6–10, 2011) and after (September 26–30, 2011) implementation of DST at 2 hospital sites in 1 health region. Medication turnaround time was defined as the time from composition of a medication order by the prescriber to its verification by the pharmacy (phase 1) and the time from prescriber composition to administration to the patient by a nurse (total). Median turnaround times were analyzed with SPSS software using the Mann–Whitney U test. Results: In total, 304 and 244 medication orders were audited before and after DST implementation, respectively. Median phase 1 turnaround time for all medications declined significantly, from 2 h 23 min before DST implementation to 1 h 33 min after DST implementation (p < 0.001). Antibiotics were also processed significantly faster (1 h 51 min versus 1 h 9 min, p = 0.015). However, total turnaround time for all medications did not differ significantly (5 h 15 min versus 5 h 0 min, p = 0.42). Conclusions: Implementation of DST was associated with a 50-min decrease in medication turnaround time for the period from when an order was prescribed to the time it was processed by the pharmacy. Regular evaluation of medication turnaround times is recommended to compare with benchmarks, to ensure that hospital standards are being met, and to measure the effects of policy changes and implementation of new technology on medication-use processes. PMID:25548397

  6. Decreasing medication turnaround time with digital scanning technology in a canadian health region.

    PubMed

    Neville, Heather; Nodwell, Lisa; Alsharif, Sahar

    2014-11-01

    Reducing medication turnaround time can improve efficiency, patient safety, and quality of care in the hospital setting. Digital scanning technology (DST) can be used to electronically transmit scanned prescriber orders to a pharmacy computer queue for verification and processing, which may help to improve medication turnaround time. To evaluate medication turnaround time before and after implementation of DST for all medications and for antibiotics only. Medication turnaround times were evaluated retrospectively for periods before (June 6-10, 2011) and after (September 26-30, 2011) implementation of DST at 2 hospital sites in 1 health region. Medication turnaround time was defined as the time from composition of a medication order by the prescriber to its verification by the pharmacy (phase 1) and the time from prescriber composition to administration to the patient by a nurse (total). Median turnaround times were analyzed with SPSS software using the Mann-Whitney U test. In total, 304 and 244 medication orders were audited before and after DST implementation, respectively. Median phase 1 turnaround time for all medications declined significantly, from 2 h 23 min before DST implementation to 1 h 33 min after DST implementation (p < 0.001). Antibiotics were also processed significantly faster (1 h 51 min versus 1 h 9 min, p = 0.015). However, total turnaround time for all medications did not differ significantly (5 h 15 min versus 5 h 0 min, p = 0.42). Implementation of DST was associated with a 50-min decrease in medication turnaround time for the period from when an order was prescribed to the time it was processed by the pharmacy. Regular evaluation of medication turnaround times is recommended to compare with benchmarks, to ensure that hospital standards are being met, and to measure the effects of policy changes and implementation of new technology on medication-use processes.

  7. Optimization of scan initiation timing after 11C-methionine administration for the diagnosis of suspected recurrent brain tumors.

    PubMed

    Nakajima, Reiko; Abe, Koichiro; Momose, Mitsuru; Fukushima, Kenji; Matsuo, Yuka; Kimura, Ken; Kondo, Chisato; Sakai, Shuji

    2017-02-01

    11 C-Methionine (MET) positron emission tomography (PET) imaging is a valuable technique for the evaluation of primary and recurrent brain tumors. Many studies have used MET-PET for data acquisition starting at 20 min after the tracer injection, while others have used scan initiation times at 5-15 min postinjection. No previous studies have identified the best acquisition timing during MET-PET imaging for suspected recurrent brain tumors. Here we sought to determine the optimal scan initiating timing after MET administration for the detection of recurrent brain tumors. Twenty-three consecutive patients with suspected recurrent brain tumors underwent MET-PET examinations. Brain PET images were reconstructed from the four serial data sets (10-15, 15-20, 20-25, and 25-30 min postinjection) that were obtained using the list-mode acquisition technique. We determined the maximal standardized uptake values (SUVmax) of the target lesions and the target-to-normal-tissue ratios (TNRs), calculated as the SUVmax to the SUVmean of a region of interest placed on the normal contralateral frontal cortex. Target lesions without significant MET uptake were excluded. Thirty-one lesions from 23 patients were enrolled. There were no significant differences in MET SUVmax or TNR values among the PET images that were reconstructed with the data extracted from the four phases postinjection. The MET uptake in the suspected recurrent brain tumors was comparable among all data extraction time phases from 10 to 30 min postinjection. The scan initiation time of MET-PET at 10 min after the injection is allowable for the detection of recurrent brain tumors. The registration identification number of the original study is 1002.

  8. Evaluation of optimized magnetic resonance perfusion imaging scanning time window after contrast agent injection for differentiating benign and malignant breast lesions

    PubMed Central

    Dong, Jie; Wang, Dawei; Ma, Zhenshen; Deng, Guodong; Wang, Lanhua; Zhang, Jiandong

    2017-01-01

    The aim of the study was evaluate the 3.0 T magnetic resonance (MR) perfusion imaging scanning time window following contrast injection for differentiating benign and malignant breast lesions and to determine the optimum scanning time window for increased scanner usage efficiency and reduced diagnostic adverse risk factors. A total of 52 women with breast abnormalities were selected for conventional MR imaging and T1 dynamic-enhanced imaging. Quantitative parameters [volume transfer constant (Ktrans), rate constant (Kep) and extravascular extracellular volume fraction (Ve)] were calculated at phases 10, 20, 30, 40 and 50, which represented time windows at 5, 10, 15, 20 and 25 min, respectively, following injection of contrast agent. The association of the parameters at different phases with benign and malignant tumor diagnosis was analyzed. MR perfusion imaging was verified as an effective modality in the diagnosis of breast malignancies and the best scanning time window was identified: i) Values of Ktrans and Kep at all phases were statistically significant in differentiating benign and malignant tumors (P<0.05), while the value of Ve had statistical significance only at stage 10, but not at any other stages (P>0.05); ii) values of Ve in benign tumors increased with phase number, but achieved no obvious changes at different phases in malignant tumors; iii) the optimum scanning time window of breast perfusion imaging with 3.0 T MR was between phases 10 and 30 (i.e., between 5 and 15 min after contrast agent injection). The variation trend of Ve values at different phases may serve as a diagnostic reference for differentiating benign and malignant breast abnormalities. The most efficient scanning time window was indicated to be 5 min after contrast injection, based on the observation that the Ve value only had statistical significance in diagnosis at stage 10. However, the optimal scanning time window is from 5 to 15 min following the injection of contrast agent, since that the variation trend of Ve is able to serve as a diagnostic reference. PMID:28450944

  9. Evaluation of optimized magnetic resonance perfusion imaging scanning time window after contrast agent injection for differentiating benign and malignant breast lesions.

    PubMed

    Dong, Jie; Wang, Dawei; Ma, Zhenshen; Deng, Guodong; Wang, Lanhua; Zhang, Jiandong

    2017-03-01

    The aim of the study was evaluate the 3.0 T magnetic resonance (MR) perfusion imaging scanning time window following contrast injection for differentiating benign and malignant breast lesions and to determine the optimum scanning time window for increased scanner usage efficiency and reduced diagnostic adverse risk factors. A total of 52 women with breast abnormalities were selected for conventional MR imaging and T1 dynamic-enhanced imaging. Quantitative parameters [volume transfer constant (K trans ), rate constant (K ep ) and extravascular extracellular volume fraction (V e )] were calculated at phases 10, 20, 30, 40 and 50, which represented time windows at 5, 10, 15, 20 and 25 min, respectively, following injection of contrast agent. The association of the parameters at different phases with benign and malignant tumor diagnosis was analyzed. MR perfusion imaging was verified as an effective modality in the diagnosis of breast malignancies and the best scanning time window was identified: i) Values of K trans and K ep at all phases were statistically significant in differentiating benign and malignant tumors (P<0.05), while the value of V e had statistical significance only at stage 10, but not at any other stages (P>0.05); ii) values of V e in benign tumors increased with phase number, but achieved no obvious changes at different phases in malignant tumors; iii) the optimum scanning time window of breast perfusion imaging with 3.0 T MR was between phases 10 and 30 (i.e., between 5 and 15 min after contrast agent injection). The variation trend of V e values at different phases may serve as a diagnostic reference for differentiating benign and malignant breast abnormalities. The most efficient scanning time window was indicated to be 5 min after contrast injection, based on the observation that the V e value only had statistical significance in diagnosis at stage 10. However, the optimal scanning time window is from 5 to 15 min following the injection of contrast agent, since that the variation trend of V e is able to serve as a diagnostic reference.

  10. Multi-slice computed tomography 5-minute delayed scan is superior to immediate scan after contrast media application in characterization of intracranial tuberculosis.

    PubMed

    Hou, Dailun; Qu, Huifang; Zhang, Xu; Li, Ning; Liu, Cheng; Ma, Xiangxing

    2014-09-02

    The aim of this study was to determine whether the diagnosis of intracranial tuberculosis (TB) can be improved when multi-slice computed tomography (MSCT) scans are taken with a 5-min delay after contrast media application. Pre- and post-contrast CT scans of the head were obtained from 30 patients using a 16-slice spiral CT. Dual-phase acquisition was performed immediately and 5 min after contrast agent injection. Diagnostic values of different images were compared using a scoring system applied by 2 experienced radiologists. We found 526 lesions in 30 patients, including 22 meningeal thickenings, 235 meningeal tuberculomas/tubercles, and 269 parenchymal tuberculomas/tubercles. Images obtained with 5-min delayed scan time were superior in terms of lesion size and meningeal thickening outlining in all disease types (P<0.01). The ability to distinguish between vascular sections from the cerebral sulcus and tubercle was also improved (P<0.01). Image acquisition with 5-min delay after contrast agent injection should be performed as a standard scanning protocol to diagnose intracranial TB.

  11. Multicenter Clinical Trials Using 18F-FDG PET to Measure Early Response to Oncologic Therapy: Effects of Injection-to-Acquisition Time Variability on Required Sample Size.

    PubMed

    Kurland, Brenda F; Muzi, Mark; Peterson, Lanell M; Doot, Robert K; Wangerin, Kristen A; Mankoff, David A; Linden, Hannah M; Kinahan, Paul E

    2016-02-01

    Uptake time (interval between tracer injection and image acquisition) affects the SUV measured for tumors in (18)F-FDG PET images. With dissimilar uptake times, changes in tumor SUVs will be under- or overestimated. This study examined the influence of uptake time on tumor response assessment using a virtual clinical trials approach. Tumor kinetic parameters were estimated from dynamic (18)F-FDG PET scans of breast cancer patients and used to simulate time-activity curves for 45-120 min after injection. Five-minute uptake time frames followed 4 scenarios: the first was a standardized static uptake time (the SUV from 60 to 65 min was selected for all scans), the second was uptake times sampled from an academic PET facility with strict adherence to standardization protocols, the third was a distribution similar to scenario 2 but with greater deviation from standards, and the fourth was a mixture of hurried scans (45- to 65-min start of image acquisition) and frequent delays (58- to 115-min uptake time). The proportion of out-of-range scans (<50 or >70 min, or >15-min difference between paired scans) was 0%, 20%, 44%, and 64% for scenarios 1, 2, 3, and 4, respectively. A published SUV correction based on local linearity of uptake-time dependence was applied in a separate analysis. Influence of uptake-time variation was assessed as sensitivity for detecting response (probability of observing a change of ≥30% decrease in (18)F-FDG PET SUV given a true decrease of 40%) and specificity (probability of observing an absolute change of <30% given no true change). Sensitivity was 96% for scenario 1, and ranged from 73% for scenario 4 (95% confidence interval, 70%-76%) to 92% (90%-93%) for scenario 2. Specificity for all scenarios was at least 91%. Single-arm phase II trials required an 8%-115% greater sample size for scenarios 2-4 than for scenario 1. If uptake time is known, SUV correction methods may raise sensitivity to 87%-95% and reduce the sample size increase to less than 27%. Uptake-time deviations from standardized protocols occur frequently, potentially decreasing the performance of (18)F-FDG PET response biomarkers. Correcting SUV for uptake time improves sensitivity, but algorithm refinement is needed. Stricter uptake-time control and effective correction algorithms could improve power and decrease costs for clinical trials using (18)F-FDG PET endpoints. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  12. Effect of Resting-State fNIRS Scanning Duration on Functional Brain Connectivity and Graph Theory Metrics of Brain Network.

    PubMed

    Geng, Shujie; Liu, Xiangyu; Biswal, Bharat B; Niu, Haijing

    2017-01-01

    As an emerging brain imaging technique, functional near infrared spectroscopy (fNIRS) has attracted widespread attention for advancing resting-state functional connectivity (FC) and graph theoretical analyses of brain networks. However, it remains largely unknown how the duration of the fNIRS signal scanning is related to stable and reproducible functional brain network features. To answer this question, we collected resting-state fNIRS signals (10-min duration, two runs) from 18 participants and then truncated the hemodynamic time series into 30-s time bins that ranged from 1 to 10 min. Measures of nodal efficiency, nodal betweenness, network local efficiency, global efficiency, and clustering coefficient were computed for each subject at each fNIRS signal acquisition duration. Analyses of the stability and between-run reproducibility were performed to identify optimal time length for each measure. We found that the FC, nodal efficiency and nodal betweenness stabilized and were reproducible after 1 min of fNIRS signal acquisition, whereas network clustering coefficient, local and global efficiencies stabilized after 1 min and were reproducible after 5 min of fNIRS signal acquisition for only local and global efficiencies. These quantitative results provide direct evidence regarding the choice of the resting-state fNIRS scanning duration for functional brain connectivity and topological metric stability of brain network connectivity.

  13. Evolution of motion uncertainty in rectal cancer: implications for adaptive radiotherapy

    NASA Astrophysics Data System (ADS)

    Kleijnen, Jean-Paul J. E.; van Asselen, Bram; Burbach, Johannes P. M.; Intven, Martijn; Philippens, Marielle E. P.; Reerink, Onne; Lagendijk, Jan J. W.; Raaymakers, Bas W.

    2016-01-01

    Reduction of motion uncertainty by applying adaptive radiotherapy strategies depends largely on the temporal behavior of this motion. To fully optimize adaptive strategies, insight into target motion is needed. The purpose of this study was to analyze stability and evolution in time of motion uncertainty of both the gross tumor volume (GTV) and clinical target volume (CTV) for patients with rectal cancer. We scanned 16 patients daily during one week, on a 1.5 T MRI scanner in treatment position, prior to each radiotherapy fraction. Single slice sagittal cine MRIs were made at the beginning, middle, and end of each scan session, for one minute at 2 Hz temporal resolution. GTV and CTV motion were determined by registering a delineated reference frame to time-points later in time. The 95th percentile of observed motion (dist95%) was taken as a measure of motion. The stability of motion in time was evaluated within each cine-MRI separately. The evolution of motion was investigated between the reference frame and the cine-MRIs of a single scan session and between the reference frame and the cine-MRIs of several days later in the course of treatment. This observed motion was then converted into a PTV-margin estimate. Within a one minute cine-MRI scan, motion was found to be stable and small. Independent of the time-point within the scan session, the average dist95% remains below 3.6 mm and 2.3 mm for CTV and GTV, respectively 90% of the time. We found similar motion over time intervals from 18 min to 4 days. When reducing the time interval from 18 min to 1 min, a large reduction in motion uncertainty is observed. A reduction in motion uncertainty, and thus the PTV-margin estimate, of 71% and 75% for CTV and tumor was observed, respectively. Time intervals of 15 and 30 s yield no further reduction in motion uncertainty compared to a 1 min time interval.

  14. A study on quantitative analysis of exposure dose caused by patient depending on time and distance in nuclear medicine examination

    NASA Astrophysics Data System (ADS)

    Kim, H. S.; Cho, J. H.; Shin, S. G.; Dong, K. R.; Chung, W. K.; Chung, J. E.

    2013-01-01

    This study evaluated possible actions that can help protect against and reduce radiation exposure by measuring the exposure dose for each type of isotope that is used frequently in nuclear medicine before performing numerical analysis of the effective half-life based on the measurement results. From July to August in 2010, the study targeted 10, 6 and 5 people who underwent an 18F-FDG (fludeoxyglucose) positron emission tomography (PET) scan, 99mTc-HDP bone scan, and 201Tl myocardial single-photon emission computed tomography (SPECT) scan, respectively, in the nuclear medicine department. After injecting the required medicine into the subjects, a survey meter was used to measure the dose depending on the distance from the heart and time elapsed. For the 18F-FDG PET scan, the dose decreased by approximately 66% at 90 min compared to that immediately after the injection and by 78% at a distance of 1 m compared to that at 0.3 m. In the 99mTc-HDP bone scan, the dose decreased by approximately 71% in 200 min compared to that immediately after the injection and by approximately 78% at a distance of 1 m compared to that at 0.3 m. In the 201Tl myocardial SPECT scan, the dose decreased by approximately 30% in 250 min compared to that immediately after the injection and by approximately 55% at a distance of 1 m compared to that at 0.3 m. In conclusion, the dose decreases by a large margin depending on the distance and time. In conclusion, this study measured the exposure doses by isotopes, distance from the heart and exposure time, and found that the doses were reduced significantly according the distance and the time.

  15. Early PET imaging with [68]Ga-PSMA-11 increases the detection rate of local recurrence in prostate cancer patients with biochemical recurrence.

    PubMed

    Uprimny, Christian; Kroiss, Alexander Stephan; Fritz, Josef; Decristoforo, Clemens; Kendler, Dorota; von Guggenberg, Elisabeth; Nilica, Bernhard; Maffey-Steffan, Johanna; di Santo, Gianpaolo; Bektic, Jasmin; Horninger, Wolfgang; Virgolini, Irene Johanna

    2017-09-01

    PET/CT using 68 Ga-labelled prostate-specific membrane antigen PSMA-11 (HBEDD-CC) has emerged as a promising imaging method in the diagnostic evaluation of prostate cancer (PC) patients with biochemical recurrence. However, assessment of local recurrence (LR) may be limited by intense physiologic tracer accumulation in the urinary bladder on whole-body scans, normally conducted 60 min post-tracer injection (p.i.). It could be shown on early dynamic imaging studies that 68 Ga-PSMA-11 uptake in PC lesions occurs earlier than tracer accumulation in the urinary bladder. This study aims to investigate whether early static PET acquisition increases detection rate of local recurrence on 68 Ga-PSMA-11 PET/CT in comparison to PET imaging 60 min p.i.. 203 consecutive PC patients with biochemical failure referred to 68 Ga-PSMA-11 PET/CT were analysed retrospectively (median prostate specific antigen (PSA) value: 1.44 ng/ml). In addition to whole-body PET/CT scans 60 min p.i., early static imaging of the pelvis was performed, starting at a median time of 283 s p.i. (range: 243-491 s). Assessment was based on visual analysis and calculation of maximum standardized uptake value (SUV max ) of pathologic lesions present in the pelvic area found on early PET imaging and on 60 min-PET scans. 26 patients (12.8%) were judged positive for LR on PET scans 60 min p.i. (median SUV max : 10.8; range: 4.7-40.9), whereas 50 patients (24.6%) revealed a lesion suggestive of LR on early PET imaging (median SUV max : 5.9; range: 2.9-17.6), resulting in a significant rise in detection rate (p < 0.001). Equivocal findings on PET scans 60 min p.i. decreased significantly with the help of early imaging (15.8% vs. 4.5% of patients; p < 0.001). Tracer activity in the urinary bladder with a median SUV max of 8.2 was present in 63 patients on early PET scans (31.0%). However, acquisition starting time of early PET scans differed significantly in the patient groups with and without urinary bladder activity (median starting time of 321 vs. 275 s p.i.; range: 281-491 vs. 243-311 s p.i.; p < 0.001). Median SUV max value of lesions suggestive of LR on early images was significantly higher in comparison to gluteal muscle, inguinal vessels and seminal vesicle/anastomosis (median SUV max : 5.9 vs. 1.9, 4.0 and 2.4, respectively). Performance of early imaging in 68 Ga-PSMA-11 PET/CT in addition to whole-body scans 60 min p.i. increases the detection rate of local recurrence in PC patients with biochemical recurrence. Acquisition of early PET images should be started as early as 5 min p.i. in order to avoid disturbing tracer activity in the urinary bladder occuring at a later time point.

  16. A 1-minute full brain MR exam using a multicontrast EPI sequence.

    PubMed

    Skare, Stefan; Sprenger, Tim; Norbeck, Ola; Rydén, Henric; Blomberg, Lars; Avventi, Enrico; Engström, Mathias

    2018-06-01

    A new multicontrast echo-planar imaging (EPI)-based sequence is proposed for brain MRI, which can directly generate six MR contrasts (T 1 -FLAIR, T 2 -w, diffusion-weighted (DWI), apparent diffusion coefficient (ADC), T2*-w, T 2 -FLAIR) in 1 min with full brain coverage. This could enable clinical MR clinical screening in similar time as a conventional CT exam but with more soft-tissue information. Eleven sequence modules were created as dynamic building blocks for the sequence. Two EPI readout modules were reused throughout the sequence and were prepended by other modules to form the desired MR contrasts. Two scan protocols were optimized with scan times of 55-75 s. Motion experiments were carried out on two volunteers to investigate the robustness against head motion. Scans on patients were carried out and compared to conventional clinical images. The pulse sequence is found to be robust against motion given its single-shot nature of each contrast. For excessive out-of-plane head motion, the T 1 -FLAIR and T 2 -FLAIR contrasts suffer from incomplete inversion. Despite lower signal-to-noise ratio (SNR) and resolution, the 1-min multicontrast EPI data show promising correspondence with conventional diagnostic scans on patients. A 1 min multicontrast brain MRI scan based on EPI readouts has been presented in this feasibility study. Preliminary data show potential for clinical brain MRI use with minimal bore time for the patient. Such short examination time could be useful (e.g., for screening and acute stroke). The sequence may also help planning conventional brain MRI scans if run at the beginning of an examination. Magn Reson Med 79:3045-3054, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  17. PET Quantification of the Norepinephrine Transporter in Human Brain with (S,S)-18F-FMeNER-D2.

    PubMed

    Moriguchi, Sho; Kimura, Yasuyuki; Ichise, Masanori; Arakawa, Ryosuke; Takano, Harumasa; Seki, Chie; Ikoma, Yoko; Takahata, Keisuke; Nagashima, Tomohisa; Yamada, Makiko; Mimura, Masaru; Suhara, Tetsuya

    2017-07-01

    Norepinephrine transporter (NET) in the brain plays important roles in human cognition and the pathophysiology of psychiatric disorders. Two radioligands, ( S , S )- 11 C-MRB and ( S , S )- 18 F-FMeNER-D 2 , have been used for imaging NETs in the thalamus and midbrain (including locus coeruleus) using PET in humans. However, NET density in the equally important cerebral cortex has not been well quantified because of unfavorable kinetics with ( S , S )- 11 C-MRB and defluorination with ( S , S )- 18 F-FMeNER-D 2 , which can complicate NET quantification in the cerebral cortex adjacent to the skull containing defluorinated 18 F radioactivity. In this study, we have established analysis methods of quantification of NET density in the brain including the cerebral cortex using ( S , S )- 18 F-FMeNER-D 2 PET. Methods: We analyzed our previous ( S , S )- 18 F-FMeNER-D 2 PET data of 10 healthy volunteers dynamically acquired for 240 min with arterial blood sampling. The effects of defluorination on the NET quantification in the superficial cerebral cortex was evaluated by establishing a time stability of NET density estimations with an arterial input 2-tissue-compartment model, which guided the less-invasive reference tissue model and area under the time-activity curve methods to accurately quantify NET density in all brain regions including the cerebral cortex. Results: Defluorination of ( S , S )- 18 F-FMeNER-D 2 became prominent toward the latter half of the 240-min scan. Total distribution volumes in the superficial cerebral cortex increased with the scan duration beyond 120 min. We verified that 90-min dynamic scans provided a sufficient amount of data for quantification of NET density unaffected by defluorination. Reference tissue model binding potential values from the 90-min scan data and area under the time-activity curve ratios of 70- to 90-min data allowed for the accurate quantification of NET density in the cerebral cortex. Conclusion: We have established methods of quantification of NET densities in the brain including the cerebral cortex unaffected by defluorination using ( S , S )- 18 F-FMeNER-D 2 These results suggest that we can accurately quantify NET density with a 90-min ( S , S )- 18 F-FMeNER-D 2 scan in broad brain areas. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  18. The 'pit-crew' model for improving door-to-needle times in endovascular stroke therapy: a Six-Sigma project.

    PubMed

    Rai, Ansaar T; Smith, Matthew S; Boo, SoHyun; Tarabishy, Abdul R; Hobbs, Gerald R; Carpenter, Jeffrey S

    2016-05-01

    Delays in delivering endovascular stroke therapy adversely affect outcomes. Time-sensitive treatments such as stroke interventions benefit from methodically developed protocols. Clearly defined roles in these protocols allow for parallel processing of tasks, resulting in consistent delivery of care. To present the outcomes of a quality-improvement (QI) process directed at reducing stroke treatment times in a tertiary level academic medical center. A Six-Sigma-based QI process was developed over a 3-month period. After an initial analysis, procedures were implemented and fine-tuned to identify and address rate-limiting steps in the endovascular care pathway. Prospectively recorded treatment times were then compared in two groups of patients who were treated 'before' (n=64) or 'after' (n=30) the QI process. Three time intervals were measured: emergency room (ER) to arrival for CT scan (ER-CT), CT scan to interventional laboratory arrival (CT-Lab), and interventional laboratory arrival to groin puncture (Lab-puncture). The ER-CT time was 40 (±29) min in the 'before' and 26 (±15) min in the 'after' group (p=0.008). The CT-Lab time was 87 (±47) min in the 'before' and 51 (±33) min in the 'after' group (p=0.0002). The Lab-puncture time was 24 (±11) min in the 'before' and 15 (±4) min in the 'after' group (p<0.0001). The overall ER-arrival to groin-puncture time was reduced from 2 h, 31 min (±51) min in the 'before' to 1 h, 33 min (±37) min in the 'after' group, (p<0.0001). The improved times were seen for both working hours and off-hours interventions. A protocol-driven process can significantly improve efficiency of care in time-sensitive stroke interventions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  19. Methods for motion correction evaluation using 18F-FDG human brain scans on a high-resolution PET scanner.

    PubMed

    Keller, Sune H; Sibomana, Merence; Olesen, Oline V; Svarer, Claus; Holm, Søren; Andersen, Flemming L; Højgaard, Liselotte

    2012-03-01

    Many authors have reported the importance of motion correction (MC) for PET. Patient motion during scanning disturbs kinetic analysis and degrades resolution. In addition, using misaligned transmission for attenuation and scatter correction may produce regional quantification bias in the reconstructed emission images. The purpose of this work was the development of quality control (QC) methods for MC procedures based on external motion tracking (EMT) for human scanning using an optical motion tracking system. Two scans with minor motion and 5 with major motion (as reported by the optical motion tracking system) were selected from (18)F-FDG scans acquired on a PET scanner. The motion was measured as the maximum displacement of the markers attached to the subject's head and was considered to be major if larger than 4 mm and minor if less than 2 mm. After allowing a 40- to 60-min uptake time after tracer injection, we acquired a 6-min transmission scan, followed by a 40-min emission list-mode scan. Each emission list-mode dataset was divided into 8 frames of 5 min. The reconstructed time-framed images were aligned to a selected reference frame using either EMT or the AIR (automated image registration) software. The following 3 QC methods were used to evaluate the EMT and AIR MC: a method using the ratio between 2 regions of interest with gray matter voxels (GM) and white matter voxels (WM), called GM/WM; mutual information; and cross correlation. The results of the 3 QC methods were in agreement with one another and with a visual subjective inspection of the image data. Before MC, the QC method measures varied significantly in scans with major motion and displayed limited variations on scans with minor motion. The variation was significantly reduced and measures improved after MC with AIR, whereas EMT MC performed less well. The 3 presented QC methods produced similar results and are useful for evaluating tracer-independent external-tracking motion-correction methods for human brain scans.

  20. Technical Note: Response time evolution of XR-QA2 GafChromic™ film models.

    PubMed

    Aldelaijan, Saad; Tomic, Nada; Papaconstadopoulos, Pavlos; Schneider, James; Seuntjens, Jan; Shih, Shelley; Lewis, David; Devic, Slobodan

    2018-01-01

    To evaluate the response of the newest XR-QA2 GafChromic™ film model in terms of postexposure signal growth and energy response in comparison with the older XR-QA (Version 2) model. Pieces of film were irradiated to air kerma in air values up to 12 cGy with several beam qualities (5.3-8.25 mm Al) commonly used for CT scanning. Film response was scored in terms of net reflectance from scanned film images at various points in time postirradiation ranging from 1 to 7 days and 5 months postexposure. To reconstruct the measurement signal changes with postirradiation delay, we irradiated one film piece and then scanned it at different point times starting from 2" min and up to 3 days postexposure. For all beam qualities and dose range investigated, it appears that the XR-QA2 film signal completely saturated after 15 h. Compared to 15 h postirradiation scanning time, the observed variation in net reflectance were 3%, 2%, and 1% for film scanned 2" min, 20 min, and 3 h after exposure, respectively, which is well within the measurement uncertainty of the XR-QA2 based reference radiochromic film dosimetry system. A comparison between the XR-QA (Version 2) and the XR-QA2 film response after several months (relative to their responses after 24 h) show differences in up to 8% and 1% for each film model respectively. The replacement of cesium bromide in the older XR-QA (Version 2) film model with bismuth oxide in the newer XR-QA2 film, while keeping the same single sensitive layer structure, lead to a significantly more stable postexposure response. © 2017 American Association of Physicists in Medicine.

  1. A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging.

    PubMed

    Yan, Hao; Zhen, Xin; Folkerts, Michael; Li, Yongbao; Pan, Tinsu; Cervino, Laura; Jiang, Steve B; Jia, Xun

    2014-07-01

    4D cone beam CT (4D-CBCT) has been utilized in radiation therapy to provide 4D image guidance in lung and upper abdomen area. However, clinical application of 4D-CBCT is currently limited due to the long scan time and low image quality. The purpose of this paper is to develop a new 4D-CBCT reconstruction method that restores volumetric images based on the 1-min scan data acquired with a standard 3D-CBCT protocol. The model optimizes a deformation vector field that deforms a patient-specific planning CT (p-CT), so that the calculated 4D-CBCT projections match measurements. A forward-backward splitting (FBS) method is invented to solve the optimization problem. It splits the original problem into two well-studied subproblems, i.e., image reconstruction and deformable image registration. By iteratively solving the two subproblems, FBS gradually yields correct deformation information, while maintaining high image quality. The whole workflow is implemented on a graphic-processing-unit to improve efficiency. Comprehensive evaluations have been conducted on a moving phantom and three real patient cases regarding the accuracy and quality of the reconstructed images, as well as the algorithm robustness and efficiency. The proposed algorithm reconstructs 4D-CBCT images from highly under-sampled projection data acquired with 1-min scans. Regarding the anatomical structure location accuracy, 0.204 mm average differences and 0.484 mm maximum difference are found for the phantom case, and the maximum differences of 0.3-0.5 mm for patients 1-3 are observed. As for the image quality, intensity errors below 5 and 20 HU compared to the planning CT are achieved for the phantom and the patient cases, respectively. Signal-noise-ratio values are improved by 12.74 and 5.12 times compared to results from FDK algorithm using the 1-min data and 4-min data, respectively. The computation time of the algorithm on a NVIDIA GTX590 card is 1-1.5 min per phase. High-quality 4D-CBCT imaging based on the clinically standard 1-min 3D CBCT scanning protocol is feasible via the proposed hybrid reconstruction algorithm.

  2. Kinetic analysis of IMP split dose method for two consecutive measurement of cerebral blood flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nishizawa, S.; Yonekura, Y.; Tanaka, F.

    1994-05-01

    The split dose method for two consecutive measurements of cerebral blood flow (CBF) with I-123 IMP seems to offer a great merit to the SPECT study of the brain. However, because of complexity of the dynamics of IMP, it is not clear if microsphere (MS) model permits a estimation of CBF for the 2nd dose. We applied kinetic (KN) analysis based on 2 compartment model to the dynamic SPECT scan data, and compared the results with those obtained by MS model. Dynamic SPECT (1-min scans for 50 min) was performed using 3-head SPECT camera in 5 patients to test themore » reproducibility of measured CBF and in 9 patients to test the vascular response to acetazolamide (ACZ). Two doses of IMP (111 MBq each) were injected at the time of, and 25 min after, the scan initiation. ACZ (1g) was administered at 13 min. Arterial blood samples were drawn manually during the scan and an octanol extracted input function was obtained. Dynamic scan data for 22 min was used for CBF by KN analysis (K1), and 4-min scan data at 5 min for CBF by MS model (Km), for each dose. For 2nd CBF by MS model, simple subtraction of brain activity due to the I st dose was done using 4-min scan data just prior to the 2nd dose. Reproducibility of measured CBF by KN analysis was excellent (r=0.949, 1st K1=39.2{plus_minus}5.6 and 2nd K1=38.5{plus_minus}6.6 ml/l00g/min: mean{plus_minus}SD). Vascular response to ACZ was good (1st K1=42.4{plus_minus}7.8 to 2nd K1=67.9{plus_minus}10.0) in areas without ischemia, but poor (1st K1=41.1{plus_minus}8.5 to 2nd K1=46.1{plus_minus}11.1) in ischemic areas. Compared to KN analysis, MS model underestimated 3.5% for the 1st CBF measurement and 12.8% for the 2nd. However, excellent correlation was observed not only between 1st K1 and Km (r=0.993, slope=0.920) but between 2nd K1 and Km (r=0.994, slope=0.814), and the results permitted a reasonable correction for Km.« less

  3. Evaluation and selection of anatomic sites for magnetic resonance imaging-guided mild hyperthermia therapy: a healthy volunteer study.

    PubMed

    V V N Kothapalli, Satya; Altman, Michael B; Zhu, Lifei; Partanen, Ari; Cheng, Galen; Gach, H Michael; Straube, William; Zoberi, Imran; Hallahan, Dennis E; Chen, Hong

    2018-01-04

    Since mild hyperthermia therapy (MHT) requires maintaining the temperature within a narrow window (e.g. 40-43 °C) for an extended duration (up to 1 h), accurate and precise temperature measurements are essential for ensuring safe and effective treatment. This study evaluated the precision and accuracy of MR thermometry in healthy volunteers at different anatomical sites for long scan times. A proton resonance frequency shift method was used for MR thermometry. Eight volunteers were subjected to a 5-min scanning protocol, targeting chest wall, bladder wall, and leg muscles. Six volunteers were subjected to a 30-min scanning protocol and three volunteers were subjected to a 60-min scanning protocol, both targeting the leg muscles. The precision and accuracy of the MR thermometry were quantified. Both the mean precision and accuracy <1 °C were used as criteria for acceptable thermometry. Drift-corrected MR thermometry measurements based on 5-min scans of the chest wall, bladder wall, and leg muscles had accuracies of 1.41 ± 0.65, 1.86 ± 1.20, and 0.34 ± 0.44 °C, and precisions of 2.30 ± 1.21, 1.64 ± 0.56, and 0.48 ± 0.05 °C, respectively. Measurements based on 30-min scans of the leg muscles had accuracy and precision of 0.56 ± 0.05 °C and 0.42 ± 0.50 °C, respectively, while the 60-min scans had accuracy and precision of 0.49 ± 0.03 °C and 0.56 ± 0.05 °C, respectively. Respiration, cardiac, and digestive-related motion pose challenges to MR thermometry of the chest wall and bladder wall. The leg muscles had satisfactory temperature accuracy and precision per the chosen criteria. These results indicate that extremity locations may be preferable targets for MR-guided MHT using the existing MR thermometry technique.

  4. VirtoScan - a mobile, low-cost photogrammetry setup for fast post-mortem 3D full-body documentations in x-ray computed tomography and autopsy suites.

    PubMed

    Kottner, Sören; Ebert, Lars C; Ampanozi, Garyfalia; Braun, Marcel; Thali, Michael J; Gascho, Dominic

    2017-03-01

    Injuries such as bite marks or boot prints can leave distinct patterns on the body's surface and can be used for 3D reconstructions. Although various systems for 3D surface imaging have been introduced in the forensic field, most techniques are both cost-intensive and time-consuming. In this article, we present the VirtoScan, a mobile, multi-camera rig based on close-range photogrammetry. The system can be integrated into automated PMCT scanning procedures or used manually together with lifting carts, autopsy tables and examination couch. The VirtoScan is based on a moveable frame that carries 7 digital single-lens reflex cameras. A remote control is attached to each camera and allows the simultaneous triggering of the shutter release of all cameras. Data acquisition in combination with the PMCT scanning procedures took 3:34 min for the 3D surface documentation of one side of the body compared to 20:20 min of acquisition time when using our in-house standard. A surface model comparison between the high resolution output from our in-house standard and a high resolution model from the multi-camera rig showed a mean surface deviation of 0.36 mm for the whole body scan and 0.13 mm for a second comparison of a detailed section of the scan. The use of the multi-camera rig reduces the acquisition time for whole-body surface documentations in medico-legal examinations and provides a low-cost 3D surface scanning alternative for forensic investigations.

  5. When continuous observations just won't do: developing accurate and efficient sampling strategies for the laying hen.

    PubMed

    Daigle, Courtney L; Siegford, Janice M

    2014-03-01

    Continuous observation is the most accurate way to determine animals' actual time budget and can provide a 'gold standard' representation of resource use, behavior frequency, and duration. Continuous observation is useful for capturing behaviors that are of short duration or occur infrequently. However, collecting continuous data is labor intensive and time consuming, making multiple individual or long-term data collection difficult. Six non-cage laying hens were video recorded for 15 h and behavioral data collected every 2 s were compared with data collected using scan sampling intervals of 5, 10, 15, 30, and 60 min and subsamples of 2 second observations performed for 10 min every 30 min, 15 min every 1 h, 30 min every 1.5 h, and 15 min every 2 h. Three statistical approaches were used to provide a comprehensive analysis to examine the quality of the data obtained via different sampling methods. General linear mixed models identified how the time budget from the sampling techniques differed from continuous observation. Correlation analysis identified how strongly results from the sampling techniques were associated with those from continuous observation. Regression analysis identified how well the results from the sampling techniques were associated with those from continuous observation, changes in magnitude, and whether a sampling technique had bias. Static behaviors were well represented with scan and time sampling techniques, while dynamic behaviors were best represented with time sampling techniques. Methods for identifying an appropriate sampling strategy based upon the type of behavior of interest are outlined and results for non-caged laying hens are presented. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Low voltage electrophoresis chip with multi-segments synchronized scanning

    NASA Astrophysics Data System (ADS)

    Gu, Wenwen; Wen, Zhiyu; Xu, Yi

    2017-03-01

    For low voltage electrophoresis chip, there is always a problem that the samples are truncated and peaks are broadened, as well as longer time for separation. In this paper, a low voltage electrophoresis separation model was established, and the separation conditions were discussed. A new driving mode was proposed for applying low voltage, which was called multi-segments synchronized scanning. By using this driving mode, the reversed electric field that existed between the multi-segments can enrich samples and shorten the sample zone. The low voltage electrophoresis experiments using multi-segments synchronized scanning were carried out by home-made silicon-PDMS-based chip. The fluorescein isothiocyanate (FITC) labeled lysine and phenylalanine mixed samples with the concentration of 10-4 mol/L were successfully separated under the optimal conditions of 10 mmol/L borax buffer (pH = 10.0), 200 V/cm separation electric field and electrode switch time of 2.5 s. The separation was completed with a resolution of 2.0, and the peak time for lysine and phenylalanine was 4 min and 6 min, respectively.

  7. A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yan, Hao; Folkerts, Michael; Jiang, Steve B., E-mail: xun.jia@utsouthwestern.edu, E-mail: steve.jiang@UTSouthwestern.edu

    2014-07-15

    Purpose: 4D cone beam CT (4D-CBCT) has been utilized in radiation therapy to provide 4D image guidance in lung and upper abdomen area. However, clinical application of 4D-CBCT is currently limited due to the long scan time and low image quality. The purpose of this paper is to develop a new 4D-CBCT reconstruction method that restores volumetric images based on the 1-min scan data acquired with a standard 3D-CBCT protocol. Methods: The model optimizes a deformation vector field that deforms a patient-specific planning CT (p-CT), so that the calculated 4D-CBCT projections match measurements. A forward-backward splitting (FBS) method is inventedmore » to solve the optimization problem. It splits the original problem into two well-studied subproblems, i.e., image reconstruction and deformable image registration. By iteratively solving the two subproblems, FBS gradually yields correct deformation information, while maintaining high image quality. The whole workflow is implemented on a graphic-processing-unit to improve efficiency. Comprehensive evaluations have been conducted on a moving phantom and three real patient cases regarding the accuracy and quality of the reconstructed images, as well as the algorithm robustness and efficiency. Results: The proposed algorithm reconstructs 4D-CBCT images from highly under-sampled projection data acquired with 1-min scans. Regarding the anatomical structure location accuracy, 0.204 mm average differences and 0.484 mm maximum difference are found for the phantom case, and the maximum differences of 0.3–0.5 mm for patients 1–3 are observed. As for the image quality, intensity errors below 5 and 20 HU compared to the planning CT are achieved for the phantom and the patient cases, respectively. Signal-noise-ratio values are improved by 12.74 and 5.12 times compared to results from FDK algorithm using the 1-min data and 4-min data, respectively. The computation time of the algorithm on a NVIDIA GTX590 card is 1–1.5 min per phase. Conclusions: High-quality 4D-CBCT imaging based on the clinically standard 1-min 3D CBCT scanning protocol is feasible via the proposed hybrid reconstruction algorithm.« less

  8. High-speed multislice T1 mapping using inversion-recovery echo-planar imaging.

    PubMed

    Ordidge, R J; Gibbs, P; Chapman, B; Stehling, M K; Mansfield, P

    1990-11-01

    Tissue contrast in MR images is a strong function of spin-lattice (T1) and spin-spin (T2) relaxation times. However, the T1 relaxation time is rarely quantified because of the long scan time required to produce an accurate T1 map of the subject. In a standard 2D FT technique, this procedure may take up to 30 min. Modifications of the echo-planar imaging (EPI) technique which incorporate the principle of inversion recovery (IR) enable multislice T1 maps to be produced in total scan times varying from a few seconds up to a minute. Using IR-EPI, rapid quantification of T1 values may thus lead to better discrimination between tissue types in an acceptable scan time.

  9. Single-scan rest/stress imaging: validation in a porcine model with 18F-Flurpiridaz.

    PubMed

    Guehl, Nicolas J; Normandin, Marc D; Wooten, Dustin W; Rozen, Guy; Sitek, Arkadiusk; Ruskin, Jeremy; Shoup, Timothy M; Ptaszek, Leon M; El Fakhri, Georges; Alpert, Nathaniel M

    2017-08-01

    18 F-labeled myocardial flow agents are becoming available for clinical application but the ∼2 hour half-life of 18 F complicates their clinical application for rest-stress measurements. The goal of this work is to evaluate in a pig model a single-scan method which provides quantitative rest-stress blood flow in less than 15 minutes. Single-scan rest-stress measurements were made using 18 F-Flurpiridaz. Nine scans were performed in healthy pigs and seven scans were performed in injured pigs. A two-injection, single-scan protocol was used in which an adenosine infusion was started 4 minutes after the first injection of 18 F-Flurpiridaz and followed either 3 or 6 minutes later by a second radiotracer injection. In two pigs, microsphere flow measurements were made at rest and during stress. Dynamic images were reoriented into the short axis view, and regions of interest (ROIs) for the 17 myocardial segments were defined in bull's eye fashion. PET data were fitted with MGH2, a kinetic model with time varying kinetic parameters, in which blood flow changes abruptly with the introduction of adenosine. Rest and stress myocardial blood flow (MBF) were estimated simultaneously. The first 12-14 minutes of rest-stress PET data were fitted in detail by the MGH2 model, yielding MBF measurement with a mean precision of 0.035 ml/min/cc. Mean myocardial blood flow across pigs was 0.61 ± 0.11 mL/min/cc at rest and 1.06 ± 0.19 mL/min/cc at stress in healthy pigs and 0.36 ± 0.20 mL/min/cc at rest and 0.62 ± 0.24 mL/min/cc at stress in the ischemic area. Good agreement was obtained with microsphere flow measurement (slope = 1.061 ± 0.017, intercept = 0.051 ± 0.017, mean difference 0.096 ± 0.18 ml/min/cc). Accurate rest and stress blood flow estimation can be obtained in less than 15 min of PET acquisition. The method is practical and easy to implement suggesting the possibility of clinical translation.

  10. Cryogen spray cooling during laser tissue welding.

    PubMed

    Fried, N M; Walsh, J T

    2000-03-01

    Cryogen cooling during laser tissue welding was explored as a means of reducing lateral thermal damage near the tissue surface and shortening operative time. Two centimetre long full-thickness incisions were made on the epilated backs of guinea pigs, in vivo. India ink was applied to the incision edges then clamps were used to appose the edges. A 4 mm diameter beam of 16 W, continuous-wave, 1.06 microm, Nd:YAG laser radiation was scanned over the incisions, producing approximately 100 ms pulses. There was a delay of 2 s between scans. The total irradiation time was varied from 1-2 min. Cryogen was delivered to the weld site through a solenoid valve in spurt durations of 20, 60 and 100 ms. The time between spurts was either 2 or 4 s, corresponding to one spurt every one or two laser scans. Histology and tensile strength measurements were used to evaluate laser welds. Total irradiation times were reduced from 10 min without surface cooling to under 1 min with surface cooling. The thermal denaturation profile showed less denaturation in the papillary dermis than in the mid-dermis. Welds created using optimized irradiation and cooling parameters had significantly higher tensile strengths (1.7 +/- 0.4 kg cm(-2)) than measured in the control studies without cryogen cooling (1.0 +/- 0.2 kg cm(-2)) (p < 0.05). Cryogen cooling of the tissue surface during laser welding results in increased weld strengths while reducing thermal damage and operative times. Long-term studies will be necessary to determine weld strengths and the amount of scarring during wound healing.

  11. Ga-68-DOTATOC: Feasibility of high throughput screening by small animal PET using a clinical high-resolution PET/CT scanner

    NASA Astrophysics Data System (ADS)

    Hofmann, Michael; Weitzel, Thilo; Krause, Thomas

    2006-12-01

    As radio peptide tracers have been developed in recent years for the high sensitive detection of neuroendocrine tumors, still the broad application of other peptides to breast and prostate cancer is missing. A rapid screening of new peptides can, in theory, be based on in vivo screening in animals by PET/CT. To test this hypothesis and to asses the minimum screening time needed per animal, we used the application of Ga-68-DOTATOC PET/CT in rats as test system. The Ga-68-DOTATOC yields in a hot spot imaging with minimal background. To delineate liver and spleen, we performed PET/CT of 10 animals on a SIEMENS Biograph 16 LSO HIGHREZ after intravenous injection of 1.5 MBq Ga-68-DOTATOC per animal. Animals were mounted in an '18 slot' holding device and scanned for a single-bed position. The emission times for the PET scan was varied from 1 to 20 min. The images were assessed first for "PET only" and afterwards in PET/CT fusion mode. The detection of the two organs was good at emission times down to 1 min in PET/CT fusion mode. In the "PET only" scans, the liver was clearly to be identified down to 1 min emission in all animals. But the spleen could only be delineated only by 1 min of emission in the PET/CT-fusion mode. In conclusion the screening of "hot spot" enriching peptides is feasible. "PET only" is in terms of delineation of small organs by far inferior to PET/CT fusion. If animal tumors are above a diameter of 10 mm small, animal PET/CT using clinical high resolution scanners will enable rapid screening. Even the determination of bio-distributions becomes feasible by using list mode tools. The time for the whole survey of 18 animals including anesthesia, preparation and mounting was approximately 20 min. By use of several holding devices mounted simultaneously, a survey time of less than 1 h for 180 animals can be expected.

  12. Scanning electron microscopy study of the effect of the brushing time on the human tooth dentin after exposure to acidic softdrinks.

    PubMed

    Kwoni, Eri; Choi, Samjin; Cheong, Youjin; Park, Ki-Ho; Park, Hun-Kuk

    2012-07-01

    Scanning electron microscopy (SEM) was used to examine the abrasive and erosive potential of the brushing time on the dentin surface eroded by acidic soft drinks to suggest an optimized toothbrushing start time after the consumption of cola (pH 2.52) in children. Thirty-six non-carious primary central incisors were assigned to 12 experimental groups (n = 3) based on the erosive and abrasive treatment protocols. Cola exposure was used as the erosive treatment. Three brushing durations (5, 15, and 30 sec) and four brushing start times (immediately, 30 min, 60 min, and 120 min) after an erosive pre-treatment were used for the abrasive treatment. Toothbrushing after exposure to acidic soft drinks led to an increase in the open-tubule fraction and microstructural changes. Toothbrushing immediately after the erosive pre-treatment showed the largest abrasive and erosive potential on the dentin whereas that 60 and 120 min after the pre-treatment showed the least abrasive and erosive potential on the dentin. Toothbrushing for both 60 and 120 min after the pre-treatment showed similar erosive and abrasive potentials on the dentin. The brushing duration showed no effect on the erosive and abrasive potential on the dentin. Therefore, to achieve the desired tooth surface cleaning and less surface lesion on the dentin surface, toothbrushing should be performed at least 1 hour after cola consumption. Three-minute brushing after cola consumption is sufficient to prevent dental lesions, and prolonged brushing can irritate the gingival tissues.

  13. Selected PET radiomic features remain the same.

    PubMed

    Tsujikawa, Tetsuya; Tsuyoshi, Hideaki; Kanno, Masafumi; Yamada, Shizuka; Kobayashi, Masato; Narita, Norihiko; Kimura, Hirohiko; Fujieda, Shigeharu; Yoshida, Yoshio; Okazawa, Hidehiko

    2018-04-17

    We investigated whether PET radiomic features are affected by differences in the scanner, scan protocol, and lesion location using 18 F-FDG PET/CT and PET/MR scans. SUV, TMR, skewness, kurtosis, entropy, and homogeneity strongly correlated between PET/CT and PET/MR images. SUVs were significantly higher on PET/MR 0-2 min and PET/MR 0-10 min than on PET/CT in gynecological cancer ( p = 0.008 and 0.008, respectively), whereas no significant difference was observed between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images in oral cavity/oropharyngeal cancer. TMRs on PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min increased in this order in gynecological cancer and oral cavity/oropharyngeal cancer. In contrast to conventional and histogram indices, 4 textural features (entropy, homogeneity, SRE, and LRE) were not significantly different between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images. 18 F-FDG PET radiomic features strongly correlated between PET/CT and PET/MR images. Dixon-based attenuation correction on PET/MR images underestimated tumor tracer uptake more significantly in oral cavity/oropharyngeal cancer than in gynecological cancer. 18 F-FDG PET textural features were affected less by differences in the scanner and scan protocol than conventional and histogram features, possibly due to the resampling process using a medium bin width. Eight patients with gynecological cancer and 7 with oral cavity/oropharyngeal cancer underwent a whole-body 18 F-FDG PET/CT scan and regional PET/MR scan in one day. PET/MR scans were performed for 10 minutes in the list mode, and PET/CT and 0-2 min and 0-10 min PET/MR images were reconstructed. The standardized uptake value (SUV), tumor-to-muscle SUV ratio (TMR), skewness, kurtosis, entropy, homogeneity, short-run emphasis (SRE), and long-run emphasis (LRE) were compared between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images.

  14. Influence of ageing time on hardness, microstructure and wear behaviour of AISI2507 super duplex stainless steel

    NASA Astrophysics Data System (ADS)

    Davanageri, Mahesh; Narendranath, S.; Kadoli, Ravikiran

    2017-08-01

    The effect of ageing time on hardness, microstructure and wear behaviour of super duplex stainless AISI 2507 is examined. The material was solution treated at 1050 °C and water quenched, further the ageing has been carried out at 850 °C for 30 min, 60 min and 90 min. The chromium (Cr) and molybdenum (Mo) enriched intermetallic sigma phase (σ) were found to precipitate at the ferrite/austenite interface and within the ferrite region. The concentration of intermetallic sigma phase (σ), which was quantified by a combination of scanning electron microscopy and image analysis, increases with increasing ageing time, leading to significant increase in the hardness. The x-ray diffraction (XRD) and energy dispersive x-ray (EDX) was employed to investigate the element distribution and phase identification. Wear characterstics of the aged super duplex stainless steel were measured by varying normal loads, sliding speeds, sliding distance and compared with solution treated (as-cast) specimens. Scanning electron microscopy was used to assist in analysis of worn out surfaces. The outcomes suggested that the increase in percentage of sigma phase increases hardness and wear resistance in heat-treated specimens compared to solution treated specimens (as-cast).

  15. Fast susceptibility-weighted imaging with three-dimensional short-axis propeller (SAP)-echo-planar imaging.

    PubMed

    Holdsworth, Samantha J; Yeom, Kristen W; Moseley, Michael E; Skare, S

    2015-05-01

    Susceptibility-weighted imaging (SWI) in neuroimaging can be challenging due to long scan times of three-dimensional (3D) gradient recalled echo (GRE), while faster techniques such as 3D interleaved echo-planar imaging (iEPI) are prone to motion artifacts. Here we outline and implement a 3D short-axis propeller echo-planar imaging (SAP-EPI) trajectory as a faster, motion-correctable approach for SWI. Experiments were conducted on a 3T MRI system. The 3D SAP-EPI, 3D iEPI, and 3D GRE SWI scans were acquired on two volunteers. Controlled motion experiments were conducted to test the motion-correction capability of 3D SAP-EPI. The 3D SAP-EPI SWI data were acquired on two pediatric patients as a potential alternative to 2D GRE used clinically. The 3D GRE images had a better target resolution (0.47 × 0.94 × 2 mm, scan time = 5 min), iEPI and SAP-EPI images (resolution = 0.94 × 0.94 × 2 mm) were acquired in a faster scan time (1:52 min) with twice the brain coverage. SAP-EPI showed motion-correction capability and some immunity to undersampling from rejected data. While 3D SAP-EPI suffers from some geometric distortion, its short scan time and motion-correction capability suggest that SAP-EPI may be a useful alternative to GRE and iEPI for use in SWI, particularly in uncooperative patients. © 2014 Wiley Periodicals, Inc.

  16. Accelerated self-gated UTE MRI of the murine heart

    NASA Astrophysics Data System (ADS)

    Motaal, Abdallah G.; Noorman, Nils; De Graaf, Wolter L.; Florack, Luc J.; Nicolay, Klaas; Strijkers, Gustav J.

    2014-03-01

    We introduce a new protocol to obtain radial Ultra-Short TE (UTE) MRI Cine of the beating mouse heart within reasonable measurement time. The method is based on a self-gated UTE with golden angle radial acquisition and compressed sensing reconstruction. The stochastic nature of the retrospective triggering acquisition scheme produces an under-sampled and random kt-space filling that allows for compressed sensing reconstruction, hence reducing scan time. As a standard, an intragate multislice FLASH sequence with an acquisition time of 4.5 min per slice was used to produce standard Cine movies of 4 mice hearts with 15 frames per cardiac cycle. The proposed self-gated sequence is used to produce Cine movies with short echo time. The total scan time was 11 min per slice. 6 slices were planned to cover the heart from the base to the apex. 2X, 4X and 6X under-sampled k-spaces cine movies were produced from 2, 1 and 0.7 min data acquisitions for each slice. The accelerated cine movies of the mouse hearts were successfully reconstructed with a compressed sensing algorithm. Compared to the FLASH cine images, the UTE images showed much less flow artifacts due to the short echo time. Besides, the accelerated movies had high image quality and the undersampling artifacts were effectively removed. Left ventricular functional parameters derived from the standard and the accelerated cine movies were nearly identical.

  17. WE-G-BRD-08: Motion Analysis for Rectal Cancer: Implications for Adaptive Radiotherapy On the MR-Linac

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kleijnen, J; Asselen, B van; Burbach, M

    2015-06-15

    Purpose: Purpose of this study is to find the optimal trade-off between adaptation interval and margin reduction and to define the implications of motion for rectal cancer boost radiotherapy on a MR-linac. Methods: Daily MRI scans were acquired of 16 patients, diagnosed with rectal cancer, prior to each radiotherapy fraction in one week (N=76). Each scan session consisted of T2-weighted and three 2D sagittal cine-MRI, at begin (t=0 min), middle (t=9:30 min) and end (t=18:00 min) of scan session, for 1 minute at 2 Hz temporal resolution. Tumor and clinical target volume (CTV) were delineated on each T2-weighted scan andmore » transferred to each cine-MRI. The start frame of the begin scan was used as reference and registered to frames at time-points 15, 30 and 60 seconds, 9:30 and 18:00 minutes and 1, 2, 3 and 4 days later. Per time-point, motion of delineated voxels was evaluated using the deformation vector fields of the registrations and the 95th percentile distance (dist95%) was calculated as measure of motion. Per time-point, the distance that includes 90% of all cases was taken as estimate of required planning target volume (PTV)-margin. Results: Highest motion reduction is observed going from 9:30 minutes to 60 seconds. We observe a reduction in margin estimates from 10.6 to 2.7 mm and 16.1 to 4.6 mm for tumor and CTV, respectively, when adapting every 60 seconds compared to not adapting treatment. A 75% and 71% reduction, respectively. Further reduction in adaptation time-interval yields only marginal motion reduction. For adaptation intervals longer than 18:00 minutes only small motion reductions are observed. Conclusion: The optimal adaptation interval for adaptive rectal cancer (boost) treatments on a MR-linac is 60 seconds. This results in substantial smaller PTV-margin estimates. Adaptation intervals of 18:00 minutes and higher, show little improvement in motion reduction.« less

  18. Evaluation of the reproducibility of lung motion probability distribution function (PDF) using dynamic MRI.

    PubMed

    Cai, Jing; Read, Paul W; Altes, Talissa A; Molloy, Janelle A; Brookeman, James R; Sheng, Ke

    2007-01-21

    Treatment planning based on probability distribution function (PDF) of patient geometries has been shown a potential off-line strategy to incorporate organ motion, but the application of such approach highly depends upon the reproducibility of the PDF. In this paper, we investigated the dependences of the PDF reproducibility on the imaging acquisition parameters, specifically the scan time and the frame rate. Three healthy subjects underwent a continuous 5 min magnetic resonance (MR) scan in the sagittal plane with a frame rate of approximately 10 f s-1, and the experiments were repeated with an interval of 2 to 3 weeks. A total of nine pulmonary vessels from different lung regions (upper, middle and lower) were tracked and the dependences of their displacement PDF reproducibility were evaluated as a function of scan time and frame rate. As results, the PDF reproducibility error decreased with prolonged scans and appeared to approach equilibrium state in subjects 2 and 3 within the 5 min scan. The PDF accuracy increased in the power function with the increase of frame rate; however, the PDF reproducibility showed less sensitivity to frame rate presumably due to the randomness of breathing which dominates the effects. As the key component of the PDF-based treatment planning, the reproducibility of the PDF affects the dosimetric accuracy substantially. This study provides a reference for acquiring MR-based PDF of structures in the lung.

  19. Time efficiency, difficulty, and operator's preference comparing digital and conventional implant impressions: a randomized controlled trial.

    PubMed

    Joda, Tim; Lenherr, Patrik; Dedem, Philipp; Kovaltschuk, Irina; Bragger, Urs; Zitzmann, Nicola U

    2017-10-01

    The aim of this randomized controlled trial was to analyze implant impression techniques applying intraoral scanning (IOS) and the conventional method according to time efficiency, difficulty, and operator's preference. One hundred participants (n = 100) with diverse levels of dental experience were included and randomly assigned to Group A performing digital scanning (TRIOS Pod) first or Group B conducting conventional impression (open tray with elastomer) first, while the second method was performed consecutively. A customized maxillary model with a bone-level-type implant in the right canine position (FDI-position 13) was mounted on a phantom training unit realizing a standardized situation for all participants. Outcome parameter was time efficiency, and potential influence of clinical experience, operator's perception of level of difficulty, applicability of each method, and subjective preferences were analyzed with Wilcoxon -Mann-Whitney and Kruskal-Wallis tests. Mean total work time varied between 5.01 ± 1.56 min (students) and 4.53 ± 1.34 min (dentists) for IOS, and between 12.03 ± 2.00 min (students) and 10.09 ± 1.15 min (dentists) for conventional impressions with significant differences between the two methods. Neither assignment to Group A or B, nor gender nor number of impression-taking procedures did influence working time. Difficulty and applicability of IOS was perceived more favorable compared to conventional impressions, and effectiveness of IOS was rated better by the majority of students (88%) and dentists (64%). While 76% of the students preferred IOS, 48% of the dentists were favoring conventional impressions, and 26% each IOS and either technique. For single-implant sites, the quadrant-like intraoral scanning (IOS) was more time efficient than the conventional full-arch impression technique in a phantom head simulating standardized optimal conditions. A high level of acceptance for IOS was observed among students and dentists. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Rain volume estimation over areas using satellite and radar data

    NASA Technical Reports Server (NTRS)

    Doneaud, A. A.; Vonderhaar, T. H.

    1985-01-01

    The feasibility of rain volume estimation over fixed and floating areas was investigated using rapid scan satellite data following a technique recently developed with radar data, called the Area Time Integral (ATI) technique. The radar and rapid scan GOES satellite data were collected during the Cooperative Convective Precipitation Experiment (CCOPE) and North Dakota Cloud Modification Project (NDCMP). Six multicell clusters and cells were analyzed to the present time. A two-cycle oscillation emphasizing the multicell character of the clusters is demonstrated. Three clusters were selected on each day, 12 June and 2 July. The 12 June clusters occurred during the daytime, while the 2 July clusters during the nighttime. A total of 86 time steps of radar and 79 time steps of satellite images were analyzed. There were approximately 12-min time intervals between radar scans on the average.

  1. Performance assessment of dynamic spiral scan modes with variable pitch for quantitative perfusion computed tomography.

    PubMed

    Haberland, Ulrike; Klotz, Ernst; Abolmaali, Nasreddin

    2010-07-01

    Perfusion computed tomography is increasingly being used in diagnostic radiology. Axial coverage of the traditional approach is limited to the width of the detector. Using continuous periodic table movement coverage can be increased beyond this limit. In this study, we compared tissue flow values determined from scans with a periodic spiral implementation with variable pitch with ones determined from standard dynamic scan modes. A flow phantom (preserved porcine kidney) was scanned with 2 settings of a periodic spiral (Adaptive 4D Spiral) with a range of 100 and 148 mm and a temporal sampling of 1.5 seconds. Additionally, the whole phantom was scanned with the standard dynamic mode (detector width 38.4 mm, temporal sampling 1.0 seconds) at various overlapping positions as a reference. Scan parameters (80 kV, 140 mAs, 40s scan time) were selected similar to a typical brain perfusion study. All scans were repeated 5 times. Tissue flow was calculated with a dedicated deconvolution algorithm. In a center slice and 3 additional slices at various off center positions flow values were recorded in a total of 126 regions of interest (ROI). Reproducibility was determined from the variation of the repeat scans. Agreement between periodic spirals and standard mode was determined by Bland Altman plots and correlation analysis. The reproducibility of the tissue flow determination ranged from 2.7 to 4.4 mL/100 mL/min and was similar for all scan modes. The coefficient of variation ranged from 3.9% to 6.1%. Mean tissue flow in the 126 ROIs ranged from 35 to 121 mL/100 mL/min. There was excellent correlation between both periodic spiral ranges and the standard dynamic mode with a Pearson correlation coefficient of r = 0.97. The regression slope (intercept 0) for the 100 mm range was 1.01, for the 148 mm range it was 0.97. The absolute differences per ROI varied between 1.5 and 4.1 mL/100 mL/min, the relative differences between 1.9% and 6.5%. Differences did not depend on the slice location. Periodic spiral scan modes with variable pitch and a sampling rate of 1.5 seconds can be used for the quantitative determination of tissue flow. Their performance is equivalent to equidistant sampling with standard dynamic scan modes. The ranges of 100 and 148 mm investigated allow coverage of the whole brain or an entire organ for perfusion imaging.

  2. Laser Guidance in C-Arm Cone-Beam CT-Guided Radiofrequency Ablation of Osteoid Osteoma Reduces Fluoroscopy Time

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kroes, Maarten W., E-mail: Maarten.Kroes@radboudumc.nl; Busser, Wendy M. H.; Hoogeveen, Yvonne L.

    PurposeTo assess whether laser guidance can reduce fluoroscopy and procedure time of cone-beam computed tomography (CBCT)-guided radiofrequency (RF) ablations of osteoid osteoma compared to freehand CBCT guidance.Materials and Methods32 RF ablations were retrospectively analyzed, 17 laser-guided and 15 procedures using the freehand technique. Subgroup selection of 18 ablations in the hip–pelvic region with a similar degree of difficulty was used for a direct comparison. Data are presented as median (ranges).ResultsComparison of all 32 ablations resulted in fluoroscopy times of 365 s (193–878 s) for freehand and 186 s (75–587 s) for laser-guided procedures (p = 0.004). Corresponding procedure times were 56 min (35–97 min) and 52 min (30–85 min) (p = 0.355).more » The subgroup showed comparable target sizes, needle path lengths, and number of scans between groups. Fluoroscopy times were lower for laser-guided procedures, 215 s (75–413 s), compared to 384 s (193–878 s) for freehand (p = 0.012). Procedure times were comparable between groups, 51 min (30–72 min) for laser guidance and 58 min (35–79 min) for freehand (p = 0.172).ConclusionAdding laser guidance to CBCT-guided osteoid osteoma RF ablations significantly reduced fluoroscopy time without increasing procedure time.Level of EvidenceLevel 4, case series.« less

  3. Interactive lung segmentation in abnormal human and animal chest CT scans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kockelkorn, Thessa T. J. P., E-mail: thessa@isi.uu.nl; Viergever, Max A.; Schaefer-Prokop, Cornelia M.

    2014-08-15

    Purpose: Many medical image analysis systems require segmentation of the structures of interest as a first step. For scans with gross pathology, automatic segmentation methods may fail. The authors’ aim is to develop a versatile, fast, and reliable interactive system to segment anatomical structures. In this study, this system was used for segmenting lungs in challenging thoracic computed tomography (CT) scans. Methods: In volumetric thoracic CT scans, the chest is segmented and divided into 3D volumes of interest (VOIs), containing voxels with similar densities. These VOIs are automatically labeled as either lung tissue or nonlung tissue. The automatic labeling resultsmore » can be corrected using an interactive or a supervised interactive approach. When using the supervised interactive system, the user is shown the classification results per slice, whereupon he/she can adjust incorrect labels. The system is retrained continuously, taking the corrections and approvals of the user into account. In this way, the system learns to make a better distinction between lung tissue and nonlung tissue. When using the interactive framework without supervised learning, the user corrects all incorrectly labeled VOIs manually. Both interactive segmentation tools were tested on 32 volumetric CT scans of pigs, mice and humans, containing pulmonary abnormalities. Results: On average, supervised interactive lung segmentation took under 9 min of user interaction. Algorithm computing time was 2 min on average, but can easily be reduced. On average, 2.0% of all VOIs in a scan had to be relabeled. Lung segmentation using the interactive segmentation method took on average 13 min and involved relabeling 3.0% of all VOIs on average. The resulting segmentations correspond well to manual delineations of eight axial slices per scan, with an average Dice similarity coefficient of 0.933. Conclusions: The authors have developed two fast and reliable methods for interactive lung segmentation in challenging chest CT images. Both systems do not require prior knowledge of the scans under consideration and work on a variety of scans.« less

  4. [Influence of deposition time on chromatics during nitrogen-doped diamond like carbon coating on pure titanium].

    PubMed

    Yin, Lu; Yao, Jiang-wu; Xu, De-wen

    2010-10-01

    The aim of this study was to observed the influence of deposition time on chromatics during nitrogen-doped diamond like carbon coating (N-DLC) on pure titanium by multi impulse are plasma plating machine. Applying multi impulse are plasma plating machine to produce TiN coatings on pure titanium in nitrogen atmosphere, then filming with nitrogen-doped DLC on TiN in methane (10-80 min in every 5 min). The colors of N-DLC were evaluated in the CIE1976 L*a*b* uniform color scale and Mussell notation. The surface morphology of every specimen was analyzed using scanning electron microscope (SEM) and X-ray photoelectron spectroscopy (XPS). When changing the time of N-DLC coating deposition, N-DLC surface showed different color. Golden yellow was presented when deposition time was 30 min. SEM showed that crystallization was found in N-DLC coatings, the structure changed from stable to clutter by varying the deposition time. The chromatics of N-DLC coatings on pure titanium could get golden yellow when deposition time was 30 min, then the crystallized structure was stable.

  5. Optimal Exploitation of the Temporal and Spatial Resolution of SEVIRI for the Nowcasting of Clouds

    NASA Astrophysics Data System (ADS)

    Sirch, Tobias; Bugliaro, Luca

    2015-04-01

    Optimal Exploitation of the Temporal and Spatial Resolution of SEVIRI for the Nowcasting of Clouds An algorithm was developed to forecast the development of water and ice clouds for the successive 5-120 minutes separately using satellite data from SEVIRI (Spinning Enhanced Visible and Infrared Imager) aboard Meteosat Second Generation (MSG). In order to derive cloud cover, optical thickness and cloud top height of high ice clouds "The Cirrus Optical properties derived from CALIOP and SEVIRI during day and night" (COCS, Kox et al. [2014]) algorithm is applied. For the determination of the liquid water clouds the APICS ("Algorithm for the Physical Investigation of Clouds with SEVIRI", Bugliaro e al. [2011]) cloud algorithm is used, which provides cloud cover, optical thickness and effective radius. The forecast rests upon an optical flow method determining a motion vector field from two satellite images [Zinner et al., 2008.] With the aim of determining the ideal time separation of the satellite images that are used for the determination of the cloud motion vector field for every forecast horizon time the potential of the better temporal resolution of the Meteosat Rapid Scan Service (5 instead of 15 minutes repetition rate) has been investigated. Therefore for the period from March to June 2013 forecasts up to 4 hours in time steps of 5 min based on images separated by a time interval of 5 min, 10 min, 15 min, 30 min have been created. The results show that Rapid Scan data produces a small reduction of errors for a forecast horizon up to 30 minutes. For the following time steps forecasts generated with a time interval of 15 min should be used and for forecasts up to several hours computations with a time interval of 30 min provide the best results. For a better spatial resolution the HRV channel (High Resolution Visible, 1km instead of 3km maximum spatial resolution at the subsatellite point) has been integrated into the forecast. To detect clouds the difference of the measured albedo from SEVIRI and the clear-sky albedo provided by MODIS has been used and additionally the temporal development of this quantity. A pre-requisite for this work was an adjustment of the geolocation accuracy for MSG and MODIS by shifting the MODIS data and quantifying the correlation between both data sets.

  6. Portable, Battery Operated Capillary Electrophoresis with Optical Isomer Resolution Integrated with Ionization Source for Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Moini, Mehdi; Rollman, Christopher M.

    2016-03-01

    We introduce a battery operated capillary electrophoresis electrospray ionization (CE/ESI) source for mass spectrometry with optical isomer separation capability. The source fits in front of low or high resolution mass spectrometers similar to a nanospray source with about the same weight and size. The source has two high voltage power supplies (±25 kV HVPS) capable of operating in forward or reverse polarity modes and powered by a 12 V rechargeable lithium ion battery with operation time of ~10 h. In ultrafast CE mode, in which short narrow capillaries (≤15 μm i.d., 15-25 cm long) and field gradients ≥1000 V/cm are used, peak widths at the base are <1 s wide. Under these conditions, the source provides high resolution separation, including optical isomer resolution in ~1 min. Using a low resolution mass spectrometer (LTQ Velos) with a scan time of 0.07 s/scan, baseline separation of amino acids and their optical isomers were achieved in ~1 min. Moreover, bovine serum albumin (BSA) was analyzed in ~1 min with 56% coverage using the data-dependent MS/MS. Using a high resolution mass spectrometer (Thermo Orbitrap Elite) with 15,000 resolution, the fastest scan time achieved was 0.15 s, which was adequate for CE-MS analysis when optical isomer separation is not required or when the optical isomers were well separated. Figures of merit including a detection limit of 2 fmol and linear dynamic range of two orders of magnitude were achieved for amino acids.

  7. Use of rapid-scan EPR to improve detection sensitivity for spin-trapped radicals.

    PubMed

    Mitchell, Deborah G; Rosen, Gerald M; Tseitlin, Mark; Symmes, Breanna; Eaton, Sandra S; Eaton, Gareth R

    2013-07-16

    The short lifetime of superoxide and the low rates of formation expected in vivo make detection by standard continuous wave (CW) electron paramagnetic resonance (EPR) challenging. The new rapid-scan EPR method offers improved sensitivity for these types of samples. In rapid-scan EPR, the magnetic field is scanned through resonance in a time that is short relative to electron spin relaxation times, and data are processed to obtain the absorption spectrum. To validate the application of rapid-scan EPR to spin trapping, superoxide was generated by the reaction of xanthine oxidase and hypoxanthine with rates of 0.1-6.0 μM/min and trapped with 5-tert-butoxycarbonyl-5-methyl-1-pyrroline-N-oxide (BMPO). Spin trapping with BMPO to form the BMPO-OOH adduct converts the very short-lived superoxide radical into a more stable spin adduct. There is good agreement between the hyperfine splitting parameters obtained for BMPO-OOH by CW and rapid-scan EPR. For the same signal acquisition time, the signal/noise ratio is >40 times higher for rapid-scan than for CW EPR. Rapid-scan EPR can detect superoxide produced by Enterococcus faecalis at rates that are too low for detection by CW EPR. Copyright © 2013 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  8. Detection of muscarinic receptors in the human lung using PET.

    PubMed

    Visser, T J; van Waarde, A; van der Mark, T W; Kraan, J; Ensing, K; Willemsen, A T; Elsinga, P H; Vaalburg, W

    1999-08-01

    The characterization of pulmonary muscarinic receptors with PET is still in its infancy. Because approximately 70% of the lungs consists of air and pulmonary muscarinic receptor densities are low, ligands with high receptor affinity are required to obtain reasonable signal-to-noise ratios on PET images. Therefore, the potent 11C-labeled muscarinic antagonist N-methyl-piperidin-4-yl 2-cyclohexyl-2-hydroxy-2-phenylacetate methiodide ([R]-VC-002) was developed. We administered this radioligand to four healthy human volunteers to examine its suitability for studying pulmonary muscarinic receptors in vivo. [11C]VC-002 (185 MBq, specific activity > 7.4 TBq/mmol) was intravenously injected on 2 separate days, with an interval of at least 1 wk. On the first day the volunteers were not pretreated, but on the second day they received the anticholinergic glycopyrronium bromide (Robinul; 2 x 0.1 mg intravenous) 25 and 30 min before the injection of the radiopharmaceutical. C[15O]O scans (approximately 740 MBq [20 mCi] by inhalation) were acquired before the receptor scan to calculate pulmonary blood volume. On PET images of the thorax, the lungs were clearly visible. After the volunteer was pretreated with glycopyrronium bromide, pulmonary uptake of the radioligand was reduced to 32%+/-12% of the control value at 60 min postinjection and the lungs could no longer be seen. (R)-[11C]-VC-002 was rapidly cleared from plasma and was slowly metabolized during the time course (60 min) of the PET scan. The fraction of radioligand representing parent compound decreased from 99.9% at the time of injection to 82% at 40-60 min postinjection, both in the presence and absence of Robinul. Pulmonary tissue-to-plasma ratios, calculated on a count-per-minute-per-gram basis, reached a plateau value of 17.8+/-1.2 at 40-50 min postinjection. [11C]VC-002 appears to be suitable for in vivo studies of pulmonary cholinoceptors.

  9. Randomized, single-blind, factorial design study of the interaction of food and time on intestinal activity in 99mTc-tetrofosmin stress myocardial perfusion scintigraphy.

    PubMed

    Lyngholm, Ann Marie; Pedersen, Begitte H; Petersen, Lars J

    2008-09-01

    Intestinal activity at the inferior myocardial wall represents an issue for assessment of myocardial perfusion imaging (MPI) with 99mTc-labelled tracers. The aim of this study was to investigate the effect of time and food on upper abdominal activity in 99mTc-tetrofosmin MPI. The study population consisted of 152 consecutive patients referred for routine MPI. All patients underwent 2-day stress-rest 99mTc-tetrofosmin single-photon emission computed tomography MPI. Before stress testing, patients were randomized in a factorial design to four different regimens. Group A: early scan (image acquisition initiated within 15 min after injection of the tracer) and no food; group B: early scan and food (two pieces of white bread with butter and a minimum of 450 ml of water); group C: late scan (image acquisition 30-60 min after injection of the tracer) and no food; and group D: late and scan with food. Patients underwent standard bicycle exercise or pharmacological stress test. The degree of upper abdominal activity was evaluated by trained observers blinded to the randomization code. The primary endpoint was the proportion of accepted scans in the intention-to-treat population in stress MPI. The results showed statistical significant impact on both time and food on upper abdominal activity. The primary endpoint showed that the acceptance rate improved from 55% in group A to 100% success rate in group D. An early scan reduced the acceptance rate by 30% versus a late scan [hazard ratio 0.70, 95% confidence interval 0.58-0.84; P<0.0001], whereas the addition of food improved the success rate versus no food by 27% (hazard ratio 1.27, 95% confidence interval 1.07-1.51; P=0.006). No significant interaction between food and time was observed. An analysis of accepted scans according to the actual scan time and food consumption confirmed the findings of the intention-to-treat analysis. In addition, similar findings were seen in 116 of 152 patients with a rest MPI (success rate of 53% in group A vs. 96% in group D). A combination of solid food and water administered after injection of the tracer and delayed image acquisition led to significant and clinically relevant decrease of interfering upper abdominal activity in 99mTc-tetrofosmin MPI.

  10. A scintigraphic analysis of colonic movement in patients with colostomy: changes of colonic transit time after acquaintance with irrigation.

    PubMed

    Yasuda, S; Fujii, H; Yamamoto, K; Nakagawa, M; Watanabe, I; Nakano, H

    1992-01-01

    For the purpose of making a functional assessment of colostomy irrigation, eight patients were examined. Group A was composed of four patients whose experience of irrigation was less than one year. Group B was composed of four patients who had undergone irrigation for more than two years. The capacity of the remnant colon was determined by a barium enema. Next, 74 MBq of milking technetium 99 diethylene triamine penta-acetic acid (99mTc-DTPA) was instilled with a predetermined amount of water (37 degrees C). A dynamic scan was performed for 45 min. The mean evacuation time of Groups A and B were 6 min 56 s +/- 2 min 33 s and 13 min 27 s +/- 10 min 50 s, respectively. The mean half emptying time of Groups A and B were 142.5 s +/- 7.9 s and 309.0 s +/- 181.9 s. The results suggest that the remnant colon may be habituated with irrigation. Colostomy irrigation which uses a single instillation of a measured volume of tepid water is recommended.

  11. Corneal permeability changes in dry eye disease: an observational study.

    PubMed

    Fujitani, Kenji; Gadaria, Neha; Lee, Kyu-In; Barry, Brendan; Asbell, Penny

    2016-05-13

    Diagnostic tests for dry eye disease (DED), including ocular surface disease index (OSDI), tear breakup time (TBUT), corneal fluorescein staining, and lissamine staining, have great deal of variability. We investigated whether fluorophotometry correlated with previously established DED diagnostic tests and whether it could serve as a novel objective metric to evaluate DED. Dry eye patients who have had established signs or symptoms for at least 6 months were included in this observational study. Normal subjects with no symptoms of dry eyes served as controls. Each eye had a baseline fluorescein scan prior to any fluorescein dye. Fluorescein dye was then placed into both eyes, rinsed with saline solution, and scanned at 5, 10, 15, and 30 min. Patients were administered the following diagnostic tests to correlate with fluorophotometry: OSDI, TBUT, fluorescein, and lissamine. Standard protocols were used. P < 0.05 was considered significant. Fifty eyes from 25 patients (DED = 22 eyes, 11 patients; Normal = 28 eyes, 14 patients) were included. Baseline scans of the dry eye and control groups did not show any statistical difference (p = 0.84). Fluorescein concentration of DED and normal patients showed statistical significance at all time intervals (p < 10(-5), 0.001, 0.002, 0.049 for 5, 10, 15, & 30 min respectively). Fluorophotometry values converged towards baseline as time elapsed, but both groups were still statistically different at 30 min (p < 0.01). We used four fluorophotometry scoring methods and correlated them with OSDI, TBUT, fluorescein, and lissamine along with adjusted and aggregate scores. The four scoring schemes did not show any significant correlations with the other tests, except for correlations seen with lissamine and 10 (p = 0.045, 0.034) and 15 min (p = 0.013, 0.012), and with aggregate scores and 15 min (p = 0.042, 0.017). Fluorophotometry generally did not correlate with any other DED tests, even though it showed capability of differentiating between DED and normal eyes up to 30 min after fluorescein dye instillation. There may be an aspect of DED that is missed in the current regimen of DED tests and only captured with fluorophotometry. Adding fluorophotometry may be useful in screening, diagnosing, and monitoring patients with DED.

  12. Simple and rapid quantification of serotonin transporter binding using [11C]DASB bolus plus constant infusion.

    PubMed

    Gryglewski, G; Rischka, L; Philippe, C; Hahn, A; James, G M; Klebermass, E; Hienert, M; Silberbauer, L; Vanicek, T; Kautzky, A; Berroterán-Infante, N; Nics, L; Traub-Weidinger, T; Mitterhauser, M; Wadsak, W; Hacker, M; Kasper, S; Lanzenberger, R

    2017-04-01

    In-vivo quantification of serotonin transporters (SERT) in human brain has been a mainstay of molecular imaging in the field of neuropsychiatric disorders and helped to explore the underpinnings of several medical conditions, therapeutic and environmental influences. The emergence of PET/MR hybrid systems and the heterogeneity of SERT binding call for the development of efficient methods making the investigation of larger or vulnerable populations with limited scanner time and simultaneous changes in molecular and functional measures possible. We propose [ 11 C]DASB bolus plus constant infusion for these applications and validate it against standard analyses of dynamic PET data. [ 11 C]DASB bolus/infusion optimization was performed on data acquired after [ 11 C]DASB bolus in 8 healthy subjects. Subsequently, 16 subjects underwent one scan using [ 11 C]DASB bolus plus constant infusion with K bol 160-179min and one scan after [ 11 C]DASB bolus for inter-method reliability analysis. Arterial blood sampling and metabolite analysis were performed for all scans. Distribution volumes (V T ) were obtained using Logan plots for bolus scans and ratios between tissue and plasma parent activity for bolus plus infusion scans for different time spans of the scan (V T-70 for 60-70min after start of tracer infusion, V T-90 for 75-90min, V T-120 for 100-120min) in 9 subjects. Omitting blood data, binding potentials (BP ND ) obtained using multilinear reference tissue modeling (MRTM2) and cerebellar gray matter as reference region were compared in 11 subjects. A K bol of 160min was observed to be optimal for rapid equilibration in thalamus and striatum. V T-70 showed good intraclass correlation coefficients (ICCs) of 0.61-0.70 for thalamus, striatal regions and olfactory cortex with bias ≤5.1% compared to bolus scans. ICCs increased to 0.72-0.78 for V T-90 and 0.77-0.93 for V T-120 in these regions. BP ND-90 had negligible bias ≤2.5%, low variability ≤7.9% and ICCs of 0.74-0.87; BP ND-120 had ICCs of 0.73-0.90. Low-binding cortical regions and cerebellar gray matter showed a positive bias of ~8% and ICCs 0.57-0.68 at V T-90 . Cortical BP ND suffered from high variability and bias, best results were obtained for olfactory cortex and anterior cingulate cortex with ICC=0.74-0.75 for BP ND-90 . High-density regions amygdala and midbrain had a negative bias of -5.5% and -22.5% at V T-90 with ICC 0.70 and 0.63, respectively. We have optimized the equilibrium method with [ 11 C]DASB bolus plus constant infusion and demonstrated good inter-method reliability with accepted standard methods and for SERT quantification using both V T and BP ND in a range of different brain regions. With as little as 10-15min of scanning valid estimates of SERT V T and BP ND in thalamus, amygdala, striatal and high-binding cortical regions could be obtained. Blood sampling seems vital for valid quantification of SERT in low-binding cortical regions. These methods allow the investigation of up to three subjects with a single radiosynthesis. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Quantification of intra-fraction motion in breast radiotherapy using supine magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    van Heijst, Tristan C. F.; Philippens, Mariëlle E. P.; Charaghvandi, Ramona K.; den Hartogh, Mariska D.; Lagendijk, Jan J. W.; Desirée van den Bongard, H. J. G.; van Asselen, Bram

    2016-02-01

    In early-stage breast-cancer patients, accelerated partial-breast irradiation techniques (APBI) and hypofractionation are increasingly implemented after breast-conserving surgery (BCS). For a safe and effective radiation therapy (RT), the influence of intra-fraction motion during dose delivery becomes more important as associated fraction durations increase and targets become smaller. Current image-guidance techniques are insufficient to characterize local target movement in high temporal and spatial resolution for extended durations. Magnetic resonance imaging (MRI) can provide high soft-tissue contrast, allow fast imaging, and acquire images during longer periods. The goal of this study was to quantify intra-fraction motion using MRI scans from 21 breast-cancer patients, before and after BCS, in supine RT position, on two time scales. High-temporal 2-dimensional (2D) MRI scans (cine-MRI), acquired every 0.3 s during 2 min, and three 3D MRI scans, acquired over 20 min, were performed. The tumor (bed) and whole breast were delineated on 3D scans and delineations were transferred to the cine-MRI series. Consecutive scans were rigidly registered and delineations were transformed accordingly. Motion in sub-second time-scale (derived from cine-MRI) was generally regular and limited to a median of 2 mm. Infrequently, large deviations were observed, induced by deep inspiration, but these were temporary. Movement on multi-minute scale (derived from 3D MRI) varied more, although medians were restricted to 2.2 mm or lower. Large whole-body displacements (up to 14 mm over 19 min) were sparsely observed. The impact of motion on standard RT techniques is likely small. However, in novel hypofractionated APBI techniques, whole-body shifts may affect adequate RT delivery, given the increasing fraction durations and smaller targets. Motion management may thus be required. For this, on-line MRI guidance could be provided by a hybrid MRI/RT modality, such as the University Medical Center Utrecht MRI linear accelerator.

  14. Efficiency of peracetic acid in inactivating bacteria, viruses, and spores in water determined with ATP bioluminescence, quantitative PCR, and culture-based methods.

    PubMed

    Park, Eunyoung; Lee, Cheonghoon; Bisesi, Michael; Lee, Jiyoung

    2014-03-01

    The disinfection efficiency of peracetic acid (PAA) was investigated on three microbial types using three different methods (filtration-based ATP (adenosine-triphosphate) bioluminescence, quantitative polymerase chain reaction (qPCR), culture-based method). Fecal indicator bacteria (Enterococcus faecium), virus indicator (male-specific (F(+)) coliphages (coliphages)), and protozoa disinfection surrogate (Bacillus subtilis spores (spores)) were tested. The mode of action for spore disinfection was visualized using scanning electron microscopy. The results indicated that PAA concentrations of 5 ppm (contact time: 5 min), 50 ppm (10 min), and 3,000 ppm (5 min) were needed to achieve 3-log reduction of E. faecium, coliphages, and spores, respectively. Scanning electron microscopy observation showed that PAA targets the external layers of spores. The lower reduction rates of tested microbes measured with qPCR suggest that qPCR may overestimate the surviving microbes. Collectively, PAA showed broad disinfection efficiency (susceptibility: E. faecium > coliphages > spores). For E. faecium and spores, ATP bioluminescence was substantially faster (∼5 min) than culture-based method (>24 h) and qPCR (2-3 h). This study suggests PAA as an effective alternative to inactivate broad types of microbial contaminants in water. Together with the use of rapid detection methods, this approach can be useful for urgent situations when timely response is needed for ensuring water quality.

  15. The morphological study of porous silicon formed by electrochemical anodization method

    NASA Astrophysics Data System (ADS)

    Suryana, R.; Sandi, D. K.; Nakatsuka, O.

    2018-03-01

    Due to its good physical and chemical properties, porous silicon (PSi) is very attractive to study. In this research, PSi has been fabricated on n-type Si (100) by the electrochemical anodization method. The electrolyte solution used was a mixture of HF (40%), ethanol (99%) and aquadest with volume ratio of 1:1:2, respectively. It was anodized on Si(100) surface at different current densities of 10 mA/cm2 and 20 mA/cm2 with the anodization time at each current density for 10 min, 20 min, and 30 min. The Scanning Electron Microscope (SEM) images showed that the PSi surfaces have inhomogeneous sized pores in the range of 95.00 nm–1.46 μm. The PSi layers with current density and anodization time of 10 mA/cm2 (10 min), 10mA/cm2 (20 min), and 20mA/cm2 (10 min) have spherical shaped pores while the others have some uncommon (cross sectional) shaped pores on surfaces. It is considered that the cross sectional shaped maybe caused by unstable the current during the electrochemical anodization process.

  16. Comparison of digital scanning and polyvinyl siloxane impression techniques by dental students: instructional efficiency and attitudes towards technology.

    PubMed

    Marti, A M; Harris, B T; Metz, M J; Morton, D; Scarfe, W C; Metz, C J; Lin, W-S

    2017-08-01

    With increasing use of digital scanning with restorative procedures in the dental office, it becomes necessary that educational institutions adopt instructional methodology for introducing this technology together with conventional impression techniques. To compare the time differences between instructing dental students on digital scanning (DS) (LAVA C.O.S. digital impression system) and a conventional impression technique (CI) (polyvinyl siloxane), and to compare students' attitudes and beliefs towards both techniques. Volunteer sophomore dental students (n = 25) with no prior experience in clinical impressions were recruited and IRB consent obtained. Participants responded to a pre-and post-exposure questionnaire. Participants were instructed on the use of both DS and CI for a single tooth full coverage crown restoration using a consecutive sequence of video lecture, investigator-led demonstration and independent impression exercise. The time necessary for each step (minutes) was recorded. Statistical significance was calculated using dependent t-tests (time measurements) and 2-sample Mann-Whitney (questionnaire responses). The time spent teaching students was greater for DS than CI for video lecture (15.95 and 10.07 min, P = 0.0000), demonstration time (9.06 and 4.70 min, P = 0.0000) and impression time (18.17 and 8.59 min, P = 0.0000). Prior to the instruction and practice, students considered themselves more familiar with CI (3.96) than DS (1.96) (P = 0.0000). After the instruction and practice, participants reported CI technique proved significantly easier than expected (pre-instruction: 3.52 and post-instruction: 4.08, P = 0.002). However, overall participants' perception of ease of use for DS was not influenced by this instruction and practice experience (pre-instruction: 3.84 and post-instruction: 3.56, P = 0.106). Despite the results, 96% of participants expressed an expectation that DS will become their predominant impression technique during their careers. Dental students with no clinical experience have high expectations for digital scanning, and despite their initial difficulty, expect it to become their primary impression technique during their professional futures. The instructional time necessary for introducing DS into the curriculum is significantly greater than CI in both classroom (lecture) and clinical simulation settings (investigator-led demonstration). © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Hydrolysis of bamboo biomass by subcritical water treatment.

    PubMed

    Mohan, Mood; Banerjee, Tamal; Goud, Vaibhav V

    2015-09-01

    The aim of present study was to obtain total reducing sugars (TRS) from bamboo under subcritical water (SCW) treatment in a batch reactor at the temperature ranging from 170 °C to 220 °C and 40 min hydrolysis time. Experiments were performed to investigate the effects of temperature and time on TRS yield. The maximum TRS yield (42.21%) was obtained at lower temperature (180 °C), however longer reaction time (25 min). X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopy, and scanning electron microscopy (SEM) analysis were used to characterise treated and untreated bamboo samples. The XRD profile revealed that crystallinity of bamboo increased to 71.90% with increase in temperature up to 210 °C and decreased thereafter to 70.92%. The first-order reaction kinetic model was used to fit the experimental data to obtain rate constants. From the Arrhenius plot, activation energy and pre-exponential factor at 25 min time were found to be 17.97 kJ mol(-1) and 0.154 min(-1), respectively. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Esmolol is noninferior to metoprolol in achieving a target heart rate of 65 beats/min in patients referred to coronary CT angiography: a randomized controlled clinical trial.

    PubMed

    Maurovich-Horvat, Pál; Károlyi, Mihály; Horváth, Tamás; Szilveszter, Bálint; Bartykowszki, Andrea; Jermendy, Ádám L; Panajotu, Alexisz; Celeng, Csilla; Suhai, Ferenc I; Major, Gyöngyi P; Csobay-Novák, Csaba; Hüttl, Kálmán; Merkely, Béla

    2015-01-01

    Coronary CT angiography (CTA) is an established tool to rule out coronary artery disease. Performance of coronary CTA is highly dependent on patients' heart rates (HRs). Despite widespread use of β-blockers for coronary CTA, few studies have compared various agents used to achieve adequate HR control. We sought to assess if the ultrashort-acting β-blocker intravenous esmolol is at least as efficacious as the standard of care intravenous metoprolol for HR control during coronary CTA. Patients referred to coronary CTA with a HR >65 beats/min despite oral metoprolol premedication were enrolled in the study. We studied 412 patients (211 male; mean age, 57 ± 12 years). Two hundred four patients received intravenous esmolol, and 208 received intravenous metoprolol with a stepwise bolus administration protocol. HR and blood pressure were recorded at arrival, before, during, immediately after, and 30 minutes after the coronary CTA scan. Mean HRs of the esmolol and metoprolol groups were similar at arrival (78 ± 13 beats/min vs 77 ± 12 beats/min; P = .65) and before scan (68 ± 7 beats/min vs 69 ± 7 beats/min; P = .60). However, HR during scan was lower in the esmolol group vs the metoprolol group (58 ± 6 beats/min vs 61 ± 7 beats/min; P < .0001), whereas HRs immediately and 30 minutes after the scan were higher in the esmolol group vs the metoprolol group (68 ± 7 beats/min vs 66 ± 7 beats/min; P = .01 and 65 ± 8 beats/min vs 63 ± 8 beats/min; P < .0001; respectively). HR ≤ 65 beats/min was reached in 182 of 204 patients (89%) who received intravenous esmolol vs 162 of 208 of the patients (78%) who received intravenous metoprolol (P < .05). Of note, hypotension (systolic BP <100 mm Hg) was observed right after the scan in 19 patients (9.3%) in the esmolol group and in 8 patients (3.8%) in the metoprolol group (P < .05), whereas only 5 patients (2.5%) had hypotension 30 minutes after the scan in the esmolol group compared to 8 patients (3.8%) in the metoprolol group (P = .418). Intravenous esmolol with a stepwise bolus administration protocol is at least as efficacious as the standard of care intravenous metoprolol for HR control in patients who undergo coronary CTA. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  19. Electromagnetic Real Time Navigation in the Region of the Posterior Pelvic Ring: An Experimental In-Vitro Feasibility Study and Comparison of Image Guided Techniques.

    PubMed

    Pishnamaz, Miguel; Wilkmann, Christoph; Na, Hong-Sik; Pfeffer, Jochen; Hänisch, Christoph; Janssen, Max; Bruners, Philipp; Kobbe, Philipp; Hildebrand, Frank; Schmitz-Rode, Thomas; Pape, Hans-Christoph

    2016-01-01

    Electromagnetic tracking is a relatively new technique that allows real time navigation in the absence of radiation. The aim of this study was to prove the feasibility of this technique for the treatment of posterior pelvic ring fractures and to compare the results with established image guided procedures. Tests were performed in pelvic specimens (Sawbones®) with standardized sacral fractures (Type Denis I or II). A gel matrix simulated the operative approach and a cover was used to disable visual control. The electromagnetic setup was performed by using a custom made carbon reference plate and a prototype stainless steel K-wire with an integrated sensor coil. Four different test series were performed: Group OCT: Optical navigation using preoperative CT-scans; group O3D: Optical navigation using intraoperative 3-D-fluoroscopy; group Fluoro: Conventional 2-D-fluoroscopy; group EMT: Electromagnetic navigation combined with a preoperative Dyna-CT. Accuracy of screw placement was analyzed by standardized postoperative CT-scan for each specimen. Operation time and intraoperative radiation exposure for the surgeon was documented. All data was analyzed using SPSS (Version 20, 76 Chicago, IL, USA). Statistical significance was defined as p< 0.05. 160 iliosacral screws were placed (40 per group). EMT resulted in a significantly higher incidence of optimal screw placement (EMT: 36/40) compared to the groups Fluoro (30/40; p< 0.05) and OCT (31/40; p< 0.05). Results between EMT and O3D were comparable (O3D: 37/40; n.s.). Also, the operation time was comparable between groups EMT and O3D (EMT 7.62 min vs. O3D 7.98 min; n.s.), while the surgical time was significantly shorter compared to the Fluoro group (10.69 min; p< 0.001) and the OCT group (13.3 min; p< 0.001). Electromagnetic guided iliosacral screw placement is a feasible procedure. In our experimental setup, this method was associated with improved accuracy of screw placement and shorter operation time when compared with the conventional fluoroscopy guided technique and compared to the optical navigation using preoperative CT-scans. Further studies are necessary to rule out drawbacks of this technique regarding ferromagnetic objects.

  20. Time-resolved x-ray diffraction and calorimetric studies at low scan rates

    PubMed Central

    Yao, Haruhiko; Hatta, Ichiro; Koynova, Rumiana; Tenchov, Boris

    1992-01-01

    The phase transitions of dipalmitoylphosphatidylethanolamine (DPPE) in excess water have been examined by low-angle time-resolved x-ray diffraction and calorimetry at low scan rates. The lamellar subgel/lamellar liquid-crystalline (Lc → Lα), lamellar gel/lamellar liquid-crystalline (Lβ → Lα), and lamellar liquid-crystalline/lamellar gel (Lα → Lβ) phase transitions proceed via coexistence of the initial and final phases with no detectable intermediates at scan rates 0.1 and 0.5°C/min. At constant temperature within the region of the Lβ → Lα transition the ratio of the two coexisting phases was found to be stable for over 30 min. The state of stable phase coexistence was preceded by a 150-s relaxation taking place at constant temperature after termination of the heating scan in the transition region. While no intermediate structures were present in the coexistence region, a well reproducible multipeak pattern, with at least four prominent heat capacity peaks separated in temperature by 0.4-0.5°C, has been observed in the cooling transition (Lα → Lβ) by calorimetry. The multipeak pattern became distinct with an increase of incubation time in the liquid-crystalline phase. It was also clearly resolved in the x-ray diffraction intensity versus temperature plots recorded at slow cooling rates. These data suggest that the equilibrium state of the Lα phase of hydrated DPPE is represented by a mixture of domains that differ in thermal behavior, but cannot be distinguished structurally by x-ray scattering. Imagesp689-aFIGURE 9 PMID:19431820

  1. Low-Density, Refractory Multi-Principal Element Alloys of the Cr-Nb-Ti-V-Zr System: Microstructure and Phase Analysis (Postprint)

    DTIC Science & Technology

    2012-12-19

    remelted five times, being flipped for each melt, and was in a liquid state for about 5 min during each melting event. The pre- pared cigar -shaped...section surfaces using a 136 Vickers diamond pyramid under a 500 g load applied for 20 s. The micro- structure was analyzed by scanning electron ...microscopy (SEM) using a Quanta 600F scanning electron microscope (FEI, North America NanoPort, Hillsboro, OR) equipped with backscatter electron (BSE

  2. Tailoring four-dimensional cone-beam CT acquisition settings for fiducial marker-based image guidance in radiation therapy.

    PubMed

    Jin, Peng; van Wieringen, Niek; Hulshof, Maarten C C M; Bel, Arjan; Alderliesten, Tanja

    2018-04-01

    Use of four-dimensional cone-beam CT (4D-CBCT) and fiducial markers for image guidance during radiation therapy (RT) of mobile tumors is challenging due to the trade-off among image quality, imaging dose, and scanning time. This study aimed to investigate different 4D-CBCT acquisition settings for good visibility of fiducial markers in 4D-CBCT. Using these 4D-CBCTs, the feasibility of marker-based 4D registration for RT setup verification and manual respiration-induced motion quantification was investigated. For this, we applied a dynamic phantom with three different breathing motion amplitudes and included two patients with implanted markers. Irrespective of the motion amplitude, for a medium field of view (FOV), marker visibility was improved by reducing the imaging dose per projection and increasing the number of projection images; however, the scanning time was 4 to 8 min. For a small FOV, the total imaging dose and the scanning time were reduced (62.5% of the dose using a medium FOV, 2.5 min) without losing marker visibility. However, the body contour could be missing for a small FOV, which is not preferred in RT. The marker-based 4D setup verification was feasible for both the phantom and patient data. Moreover, manual marker motion quantification can achieve a high accuracy with a mean error of [Formula: see text].

  3. Chemical removal of necrotic periodontal ligament on delayed replanted teeth by sodium hypochlorite: morphological analysis and microhardness indentation test of cementum.

    PubMed

    Bai, J; Qin, M; Zhao, Y-M; Huang, M-W; Ji, A-P

    2016-04-01

    To compare the efficacy of sodium hypochlorite (NaOCl) used at different concentrations and working times for removing necrotic periodontal ligament (PDL) from delayed replanted teeth and to observe the effects of NaOCl on surface structure and microhardness of cementum. A total of 88 healthy premolars with a single root extracted for orthodontic purposes were selected and kept dry at room temperature for 1 h. The teeth were divided into 11 groups: group 1 (control): roots were untreated; group 2: necrotic PDL was removed with gauze; groups 3-11: teeth were immersed in NaOCl at different concentrations (1, 2.5 and 5.25%) and for different working times (5, 10 and 15 min). The specimens in each group were inspected separately for cementum integrity and the presence of PDL remnants by histomorphometric analysis, confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). Another 14 healthy premolars with roots divided into two pieces were selected for Vickers microhardness indentation tests before and after NaOCl treatment. The data were analysed statistically using Wilcoxon signed-rank test of two-related samples (P = 0.05). In teeth treated with 1% NaOCl for 15 min or 5.25% NaOCl for 5 min, the cementum remained morphologically intact without cracks, and PDL remnants were absent. In the 1% NaOCl for 15 min group, the microstructure of cementum was arranged more regularly, as observed ×8000 magnification by SEM. Teeth in each of the other groups displayed cementum damage and/or the presence of PDL remnants. Microhardness tests revealed that treatment with 1% NaOCl for 15 min or 5.25% NaOCl for 5 min significantly decreased microhardness of root cementum (P < 0.05). Use of either 1% NaOCl for 15 min or 5.25% NaOCl for 5 min was effective at removing necrotic PDL from the delayed replanted teeth whilst having a minimal influence on cementum integrity. However, 1% NaOCl for 15 min was less damaging to cementum. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  4. Flutriciclamide (18F-GE180) PET: First-in-Human PET Study of Novel Third-Generation In Vivo Marker of Human Translocator Protein.

    PubMed

    Fan, Zhen; Calsolaro, Valeria; Atkinson, Rebecca A; Femminella, Grazia D; Waldman, Adam; Buckley, Christopher; Trigg, William; Brooks, David J; Hinz, Rainer; Edison, Paul

    2016-11-01

    Neuroinflammation is associated with neurodegenerative disease. PET radioligands targeting the 18-kDa translocator protein (TSPO) have been used as in vivo markers of neuroinflammation, but there is an urgent need for novel probes with improved signal-to-noise ratio. Flutriciclamide ( 18 F-GE180) is a recently developed third-generation TSPO ligand. In this first study, we evaluated the optimum scan duration and kinetic modeling strategies for 18 F-GE180 PET in (older) healthy controls. Ten healthy controls, 6 TSPO high-affinity binders, and 4 mixed-affinity binders were recruited. All subjects underwent detailed neuropsychologic tests, MRI, and a 210-min 18 F-GE180 dynamic PET/CT scan using metabolite-corrected arterial plasma input function. We evaluated 5 different kinetic models: irreversible and reversible 2-tissue-compartment models, a reversible 1-tissue model, and 2 models with an extra irreversible vascular compartment. The minimal scan duration was established using 210-min scan data. The feasibility of generating parametric maps was also investigated using graphical analysis. 18 F-GE180 concentration was higher in plasma than in whole blood during the entire scan duration. The volume of distribution (V T ) was 0.17 in high-affinity binders and 0.12 in mixed-affinity binders using the kinetic model. The model that best represented brain 18 F-GE180 kinetics across regions was the reversible 2-tissue-compartment model (2TCM4k), and 90 min resulted as the optimum scan length required to obtain stable estimates. Logan graphical analysis with arterial input function gave a V T highly consistent with V T in the kinetic model, which could be used for voxelwise analysis. We report for the first time, to our knowledge, the kinetic properties of the novel third-generation TSPO PET ligand 18 F-GE180 in humans: 2TCM4k is the optimal method to quantify the brain uptake, 90 min is the optimal scan length, and the Logan approach could be used to generate parametric maps. Although these control subjects have shown relatively low V T , the methodology presented here forms the basis for quantification for future PET studies using 18 F-GE180 in different pathologies. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  5. Four-dimensional volume-of-interest reconstruction for cone-beam computed tomography-guided radiation therapy.

    PubMed

    Ahmad, Moiz; Balter, Peter; Pan, Tinsu

    2011-10-01

    Data sufficiency are a major problem in four-dimensional cone-beam computed tomography (4D-CBCT) on linear accelerator-integrated scanners for image-guided radiotherapy. Scan times must be in the range of 4-6 min to avoid undersampling artifacts. Various image reconstruction algorithms have been proposed to accommodate undersampled data acquisitions, but these algorithms are computationally expensive, may require long reconstruction times, and may require algorithm parameters to be optimized. The authors present a novel reconstruction method, 4D volume-of-interest (4D-VOI) reconstruction which suppresses undersampling artifacts and resolves lung tumor motion for undersampled 1-min scans. The 4D-VOI reconstruction is much less computationally expensive than other 4D-CBCT algorithms. The 4D-VOI method uses respiration-correlated projection data to reconstruct a four-dimensional (4D) image inside a VOI containing the moving tumor, and uncorrelated projection data to reconstruct a three-dimensional (3D) image outside the VOI. Anatomical motion is resolved inside the VOI and blurred outside the VOI. The authors acquired a 1-min. scan of an anthropomorphic chest phantom containing a moving water-filled sphere. The authors also used previously acquired 1-min scans for two lung cancer patients who had received CBCT-guided radiation therapy. The same raw data were used to test and compare the 4D-VOI reconstruction with the standard 4D reconstruction and the McKinnon-Bates (MB) reconstruction algorithms. Both the 4D-VOI and the MB reconstructions suppress nearly all the streak artifacts compared with the standard 4D reconstruction, but the 4D-VOI has 3-8 times greater contrast-to-noise ratio than the MB reconstruction. In the dynamic chest phantom study, the 4D-VOI and the standard 4D reconstructions both resolved a moving sphere with an 18 mm displacement. The 4D-VOI reconstruction shows a motion blur of only 3 mm, whereas the MB reconstruction shows a motion blur of 13 mm. With graphics processing unit hardware used to accelerate computations, the 4D-VOI reconstruction required a 40-s reconstruction time. 4D-VOI reconstruction effectively reduces undersampling artifacts and resolves lung tumor motion in 4D-CBCT. The 4D-VOI reconstruction is computationally inexpensive compared with more sophisticated iterative algorithms. Compared with these algorithms, our 4D-VOI reconstruction is an attractive alternative in 4D-CBCT for reconstructing target motion without generating numerous streak artifacts.

  6. Four-dimensional volume-of-interest reconstruction for cone-beam computed tomography-guided radiation therapy

    PubMed Central

    Ahmad, Moiz; Balter, Peter; Pan, Tinsu

    2011-01-01

    Purpose: Data sufficiency are a major problem in four-dimensional cone-beam computed tomography (4D-CBCT) on linear accelerator-integrated scanners for image-guided radiotherapy. Scan times must be in the range of 4–6 min to avoid undersampling artifacts. Various image reconstruction algorithms have been proposed to accommodate undersampled data acquisitions, but these algorithms are computationally expensive, may require long reconstruction times, and may require algorithm parameters to be optimized. The authors present a novel reconstruction method, 4D volume-of-interest (4D-VOI) reconstruction which suppresses undersampling artifacts and resolves lung tumor motion for undersampled 1-min scans. The 4D-VOI reconstruction is much less computationally expensive than other 4D-CBCT algorithms. Methods: The 4D-VOI method uses respiration-correlated projection data to reconstruct a four-dimensional (4D) image inside a VOI containing the moving tumor, and uncorrelated projection data to reconstruct a three-dimensional (3D) image outside the VOI. Anatomical motion is resolved inside the VOI and blurred outside the VOI. The authors acquired a 1-min. scan of an anthropomorphic chest phantom containing a moving water-filled sphere. The authors also used previously acquired 1-min scans for two lung cancer patients who had received CBCT-guided radiation therapy. The same raw data were used to test and compare the 4D-VOI reconstruction with the standard 4D reconstruction and the McKinnon-Bates (MB) reconstruction algorithms. Results: Both the 4D-VOI and the MB reconstructions suppress nearly all the streak artifacts compared with the standard 4D reconstruction, but the 4D-VOI has 3–8 times greater contrast-to-noise ratio than the MB reconstruction. In the dynamic chest phantom study, the 4D-VOI and the standard 4D reconstructions both resolved a moving sphere with an 18 mm displacement. The 4D-VOI reconstruction shows a motion blur of only 3 mm, whereas the MB reconstruction shows a motion blur of 13 mm. With graphics processing unit hardware used to accelerate computations, the 4D-VOI reconstruction required a 40-s reconstruction time. Conclusions: 4D-VOI reconstruction effectively reduces undersampling artifacts and resolves lung tumor motion in 4D-CBCT. The 4D-VOI reconstruction is computationally inexpensive compared with more sophisticated iterative algorithms. Compared with these algorithms, our 4D-VOI reconstruction is an attractive alternative in 4D-CBCT for reconstructing target motion without generating numerous streak artifacts. PMID:21992381

  7. Technical note: Instantaneous sampling intervals validated from continuous video observation for behavioral recording of feedlot lambs.

    PubMed

    Pullin, A N; Pairis-Garcia, M D; Campbell, B J; Campler, M R; Proudfoot, K L

    2017-11-01

    When considering methodologies for collecting behavioral data, continuous sampling provides the most complete and accurate data set whereas instantaneous sampling can provide similar results and also increase the efficiency of data collection. However, instantaneous time intervals require validation to ensure accurate estimation of the data. Therefore, the objective of this study was to validate scan sampling intervals for lambs housed in a feedlot environment. Feeding, lying, standing, drinking, locomotion, and oral manipulation were measured on 18 crossbred lambs housed in an indoor feedlot facility for 14 h (0600-2000 h). Data from continuous sampling were compared with data from instantaneous scan sampling intervals of 5, 10, 15, and 20 min using a linear regression analysis. Three criteria determined if a time interval accurately estimated behaviors: 1) ≥ 0.90, 2) slope not statistically different from 1 ( > 0.05), and 3) intercept not statistically different from 0 ( > 0.05). Estimations for lying behavior were accurate up to 20-min intervals, whereas feeding and standing behaviors were accurate only at 5-min intervals (i.e., met all 3 regression criteria). Drinking, locomotion, and oral manipulation demonstrated poor associations () for all tested intervals. The results from this study suggest that a 5-min instantaneous sampling interval will accurately estimate lying, feeding, and standing behaviors for lambs housed in a feedlot, whereas continuous sampling is recommended for the remaining behaviors. This methodology will contribute toward the efficiency, accuracy, and transparency of future behavioral data collection in lamb behavior research.

  8. Atlas-Based Segmentation Improves Consistency and Decreases Time Required for Contouring Postoperative Endometrial Cancer Nodal Volumes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Young, Amy V.; Department of Radiation Oncology, St. Luke's-Roosevelt Hospital, New York, NY; Wortham, Angela

    2011-03-01

    Purpose: Accurate target delineation of the nodal volumes is essential for three-dimensional conformal and intensity-modulated radiotherapy planning for endometrial cancer adjuvant therapy. We hypothesized that atlas-based segmentation ('autocontouring') would lead to time savings and more consistent contours among physicians. Methods and Materials: A reference anatomy atlas was constructed using the data from 15 postoperative endometrial cancer patients by contouring the pelvic nodal clinical target volume on the simulation computed tomography scan according to the Radiation Therapy Oncology Group 0418 trial using commercially available software. On the simulation computed tomography scans from 10 additional endometrial cancer patients, the nodal clinical targetmore » volume autocontours were generated. Three radiation oncologists corrected the autocontours and delineated the manual nodal contours under timed conditions while unaware of the other contours. The time difference was determined, and the overlap of the contours was calculated using Dice's coefficient. Results: For all physicians, manual contouring of the pelvic nodal target volumes and editing the autocontours required a mean {+-} standard deviation of 32 {+-} 9 vs. 23 {+-} 7 minutes, respectively (p = .000001), a 26% time savings. For each physician, the time required to delineate the manual contours vs. correcting the autocontours was 30 {+-} 3 vs. 21 {+-} 5 min (p = .003), 39 {+-} 12 vs. 30 {+-} 5 min (p = .055), and 29 {+-} 5 vs. 20 {+-} 5 min (p = .0002). The mean overlap increased from manual contouring (0.77) to correcting the autocontours (0.79; p = .038). Conclusion: The results of our study have shown that autocontouring leads to increased consistency and time savings when contouring the nodal target volumes for adjuvant treatment of endometrial cancer, although the autocontours still required careful editing to ensure that the lymph nodes at risk of recurrence are properly included in the target volume.« less

  9. In situ two-dimensional imaging quick-scanning XAFS with pixel array detector.

    PubMed

    Tanida, Hajime; Yamashige, Hisao; Orikasa, Yuki; Oishi, Masatsugu; Takanashi, Yu; Fujimoto, Takahiro; Sato, Kenji; Takamatsu, Daiko; Murayama, Haruno; Arai, Hajime; Matsubara, Eiichiro; Uchimoto, Yoshiharu; Ogumi, Zempachi

    2011-11-01

    Quick-scanning X-ray absorption fine structure (XAFS) measurements were performed in transmission mode using a PILATUS 100K pixel array detector (PAD). The method can display a two-dimensional image for a large area of the order of a centimetre with a spatial resolution of 0.2 mm at each energy point in the XAFS spectrum. The time resolution of the quick-scanning method ranged from 10 s to 1 min per spectrum depending on the energy range. The PAD has a wide dynamic range and low noise, so the obtained spectra have a good signal-to-noise ratio.

  10. Repeatable noninvasive measurement of mouse myocardial glucose uptake with 18F-FDG: evaluation of tracer kinetics in a type 1 diabetes model.

    PubMed

    Thorn, Stephanie L; deKemp, Robert A; Dumouchel, Tyler; Klein, Ran; Renaud, Jennifer M; Wells, R Glenn; Gollob, Michael H; Beanlands, Rob S; DaSilva, Jean N

    2013-09-01

    A noninvasive and repeatable method for assessing mouse myocardial glucose uptake with (18)F-FDG PET and Patlak kinetic analysis was systematically assessed using the vena cava image-derived blood input function (IDIF). Contrast CT and computer modeling was used to determine the vena cava recovery coefficient. Vena cava IDIF (n = 7) was compared with the left ventricular cavity IDIF, with blood and liver activity measured ex vivo at 60 min. The test-retest repeatability (n = 9) of Patlak influx constant K(i) at 10-40 min was assessed quantitatively using Bland-Altman analysis. Myocardial glucose uptake rates (rMGU) using the vena cava IDIF were calculated at baseline (n = 8), after induction of type 1 diabetes (streptozotocin [50 mg/kg] intraperitoneally, 5 d), and after acute insulin stimulation (0.08 mU/kg of body weight intraperitoneally). These changes were analyzed with a standardized uptake value calculation at 20 and 40 min after injection to correlate to the Patlak time interval. The proximal mouse vena cava diameter was 2.54 ± 0.30 mm. The estimated recovery coefficient, calculated using nonlinear image reconstruction, decreased from 0.76 initially (time 0 to peak activity) to 0.61 for the duration of the scan. There was a 17% difference in the image-derived vena cava blood activity at 60 min, compared with the ex vivo blood activity measured in the γ-counter. The coefficient of variability for Patlak K(i) values between mice was found to be 23% with the proposed method, compared with 51% when using the left ventricular cavity IDIF (P < 0.05). No significant bias in K(i) was found between repeated scans with a coefficient of repeatability of 0.16 mL/min/g. Calculated rMGU values were reduced by 60% in type 1 diabetic mice from baseline scans (P < 0.03, ANOVA), with a subsequent increase of 40% to a level not significantly different from baseline after acute insulin treatment. These results were confirmed with a standardized uptake value measured at 20 and 40 min. The mouse vena cava IDIF provides repeatable assessment of the blood time-activity curve for Patlak kinetic modeling of rMGU. An expected significant reduction in myocardial glucose uptake was demonstrated in a type 1 diabetic mouse model, with significant recovery after acute insulin treatment, using a mouse vena cava IDIF approach.

  11. Behavior of cows during and after peak feeding time on organic and conventional dairy farms in the United Kingdom.

    PubMed

    Langford, F M; Rutherford, K M D; Sherwood, L; Jack, M C; Lawrence, A B; Haskell, M J

    2011-02-01

    The behavior of groups of housed, lactating dairy cattle was observed over 2 winter housing periods on 20 organic farms and 20 conventional farms in the United Kingdom. Three methods were used: (1) 6 video-clips of 10 min duration were captured of cows feeding at sections of the feed-bunk face during the peak feeding period (0 to 90 min) and continuously observed for aggressive interactions among cows; (2) the proportion of cows at the feed-bunk face was scanned every 15 min for 4.5h to include the peak feeding period (0 to 255 min); and (3) all nonfeeding behaviors were scanned every 15 min for 2.5h after the peak feeding period (120 to 255 min). The latter scans were analyzed post hoc for measures of cow comfort (freestall farms only). Management and health data were collected on each farm. On farms with open-fronted feed-bunk faces, a greater number of aggressive interactions occurred at the feed-bunk face at peak feeding time on organic farms than on conventional farms (organic = 36.3 ± 4.4; conventional = 29.1 ± 3.0). Higher proportions of cows were at the feed-bunk face at peak feeding on organic farms than on conventional farms (organic=0.58 ± 0.04; conventional=0.48 ± 0.03). Housing type (freestall versus straw pen) explained most differences in postfeeding behavior (proportion of ruminating cow in alleyways: freestalls=0.16±0.06 vs. straw-pen=0.08 ± 0.03), with few differences between organic and conventional herds. On freestall farms, the proportions of cows on organic farms lying down postfeeding was smaller than in conventional herds (organic=0.38 ± 0.09 vs. conventional=0.43 ± 0.07). Differences in behavior around peak feeding time could be associated with the reduction in food "quality" on organic farms compared with the energy requirement of the cows, with cows on organic farms being highly motivated to feed. A correlation was observed between farms that had high amounts of lying and farms that had high lameness prevalence (R(2)=55.3), suggesting a complex relationship between comfort and pain. Overall, the behavior of dairy cows on organic farms was not different from that of conventionally reared cows, and the results suggest that most behavioral welfare problems relating to housing could be alleviated by management practices. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  12. Comparison of dynamic FDG-microPET study in a rabbit turpentine-induced inflammatory model and in a rabbit VX2 tumor model.

    PubMed

    Hamazawa, Yoshimasa; Koyama, Koichi; Okamura, Terue; Wada, Yasuhiro; Wakasa, Tomoko; Okuma, Tomohisa; Watanabe, Yasuyoshi; Inoue, Yuichi

    2007-01-01

    We investigated the optimum time for the differentiation tumor from inflammation using dynamic FDG-microPET scans obtained by a MicroPET P4 scanner in animal models. Forty-six rabbits with 92 inflammatory lesions that were induced 2, 5, 7, 14, 30 and 60 days after 0.2 ml (Group 1) or 1.0 ml (Group 2) of turpentine oil injection were used as inflammatory models. Five rabbits with 10 VX2 tumors were used as the tumor model. Helical CT scans were performed before the PET studies. In the PET study, after 4 hours fasting, and following transmission scans and dynamic emission data acquisitions were performed until 2 hours after intravenous FDG injection. Images were reconstructed every 10 minutes using a filtered-back projection method. PET images were analyzed visually referring to CT images. For quantitative analysis, the inflammation-to-muscle (I/M) ratio and tumor-to-muscle (T/M) ratio were calculated after regions of interest were set in tumors and muscles referring to CT images and the time-I/M ratio and time-T/M ratio curves (TRCs) were prepared to show the change over time in these ratios. The histological appearance of both inflammatory lesions and tumor lesions were examined and compared with the CT and FDG-microPET images. In visual and quantitative analysis, All the I/M ratios and the T/M ratios increased over time except that Day 60 of Group 1 showed an almost flat curve. The TRC of the T/M ratio showed a linear increasing curve over time, while that of the I/M ratios showed a parabolic increasing over time at the most. FDG uptake in the inflammatory lesions reflected the histological findings. For differentiating tumors from inflammatory lesions with the early image acquired at 40 min for dual-time imaging, the delayed image must be acquired 30 min after the early image, while imaging at 90 min or later after intravenous FDG injection was necessary in single-time-point imaging. Our results suggest the possibility of shortening the overall testing time in clinical practice by adopting dual-time-point imaging rather than single-time-point imaging.

  13. Breast MRI at Very Short TE (minTE): Image Analysis of minTE Sequences on Non-Fat-Saturated, Subtracted T1-Weighted Images.

    PubMed

    Wenkel, Evelyn; Janka, Rolf; Geppert, Christian; Kaemmerer, Nadine; Hartmann, Arndt; Uder, Michael; Hammon, Matthias; Brand, Michael

    2017-02-01

    Purpose  The aim was to evaluate a minimum echo time (minTE) protocol for breast magnetic resonance imaging (MRI) in patients with breast lesions compared to a standard TE (nTE) time protocol. Methods  Breasts of 144 women were examined with a 1.5 Tesla MRI scanner. Additionally to the standard gradient-echo sequence with nTE (4.8 ms), a variant with minimum TE (1.2 ms) was used in an interleaved fashion which leads to a better temporal resolution and should reduce the scan time by approximately 50 %. Lesion sizes were measured and the signal-to-noise ratio (SNR) as well as the contrast-to-noise ratio (CNR) were calculated. Subjective confidence was evaluated using a 3-point scale before looking at the nTE sequences (1 = very sure that I can identify a lesion and classify it, 2 = quite sure that I can identify a lesion and classify it, 3 = definitely want to see nTE for final assessment) and the subjective image quality of all examinations was evaluated using a four-grade scale (1 = sharp, 2 = slight blur, 3 = moderate blur and 4 = severe blur/not evaluable) for lesion and skin sharpness. Lesion morphology and contrast enhancement were also evaluated. Results  With minTE sequences, no lesion was rated with "definitely want to see nTE sequences for final assessment". The difference of the longitudinal and transverse diameter did not differ significantly (p > 0.05). With minTE, lesions and skin were rated to be significantly more blurry (p < 0.01 for lesions and p < 0.05 for skin). There was no difference between both sequences with respect to SNR, CNR, lesion morphology, contrast enhancement and detection of multifocal disease. Conclusion  Dynamic breast MRI with a minTE protocol is feasible without a major loss of information (SNR, CNR, lesion morphology, contrast enhancement and lesion sizes) and the temporal resolution can be increased by a factor of 2 using minTE sequences. Key points   · Increase of temporal resolution for a better in-flow curve.. · Dynamic breast MRI with a shorter TE time is possible without relevant loss of information.. · Possible decrease of the overall scan time.. Citation Format · Wenkel E, Janka R, Geppert C et al. Breast MRI at Very Short TE (minTE): Image Analysis of minTE Sequences on Non-Fat-Saturated, Subtracted T1-Weighted Images. Fortschr Röntgenstr 2017; 189: 137 - 145. © Georg Thieme Verlag KG Stuttgart · New York.

  14. One-dimensional growth of hexagonal rods of metastable h-MoO3 using one-pot, rapid and environmentally benign supercritical fluid processing

    NASA Astrophysics Data System (ADS)

    Thangasamy, Pitchai; Shanmugapriya, Vadivel; Sathish, Marappan

    2018-05-01

    A facile and one-pot supercritical fluid method was demonstrated for the synthesis of phase pure crystalline h-MoO3 microrods within a short reaction time of 5 min at 400 °C. The formation of h-MoO3 was confirmed by X-ray diffraction (XRD), Fourier transform infrared (FT-IR) and Raman spectroscopic analysis. Scanning electron microscopy (SEM) and Transmission electron microscopy (TEM) images clearly revealed the formation of hexagonal h-MoO3 rods. Further, photoluminescence emission peaks corresponding to band to band transition was observed in the h-MoO3 microrods. It was observed that when increasing the reaction time from 5 min to 30 min at 400 °C, h-MoO3 microrods undergoes disintegration to α-MoO3 thin nanorods. Interestingly, h-MoO3 microrods were also formed in a reaction time of 30 min at 400 °C when reducing the volume of nitric acid from 1 mL to ∼0.5 mL. The short reaction time and simple synthetic strategy makes this method can be suitable for the synthesis of other semiconductor nanomaterials for diverse applications.

  15. 1.0 s Ultrafast MRI in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study.

    PubMed

    Fukuda, Atsushi; Fukiage, Kenichi; Futami, Tohru; Miyati, Tosiaki

    2016-06-01

    The aim of this study was to first develop and use 1.0 s ultrafast magnetic resonance imaging (MRI) to confirm the location of the femoral head in non-sedated infants with developmental dysplasia of the hip (DDH) after reduction with spica cast application in clinical settings. The ultrafast acquisition was achieved by employing a balanced steady-state free precession sequence and immobilizing the patient with dedicated sandbags. On completion of the ultrafast MRI study, all infants were sedated for conventional MRI scanning. Two orthopaedic surgeons retrospectively evaluated the image quality, result of the reduction and total MRI study time (including patient immobilization, coil setup, and scanning) in 14 DDHs of 13 infants (one with bilateral DDHs). Both reviewers stated that there were no motion artefacts for non-sedated infants during the ultrafast MRI and that the quality of both the ultrafast and conventional MRI images were acceptable to assess the femoral head location. Assessment of the reduction procedure resulted in two hips being categorized as 'incomplete reduction' requiring a re-reduction procedure. The total study time of ultrafast and conventional MRI was 6 ± 1 min and 14 ± 3 min, respectively (P < 0.001). No complications due to sedation, such as hypoxia, were reported. The average sedation waiting time was 1 h 25 min ± 34 min. The ultrafast MRI procedure reported here can be readily employed to confirm the location of the femoral head in infants with DDHs, without the use of any sedation.

  16. Effect of polyvinyl alcohol (PVA) on Ag-Cu nanopaste performance

    NASA Astrophysics Data System (ADS)

    Noordin, Norasiah Mohammad; Razak, Khairunisak Abd; Cheong, Kuan Yew

    2017-07-01

    Electronic devices used for extreme high temperature continue to be in demand, for instance in aviation, aerospace and automotive industry. The reliability of these devices strongly depends on electronic packaging. Die attach materials is vital in electronic packaging as it provides an interface in between a die and a substrate, and its quality will determine the performance of the devices. Nanopaste is one of categories classified in the die attach systems. It is a mixture of nano sized metal particles and organic additives (binder, surfactant, solvent). In this study, Ag and Cu nanoparticles was mixed into an organic binder system, polyvinyl alcohol (PVA) serves as binder and ethylene glycol functions as surfactant while deionized water used to dissolve PVA. The mixture was inserted in vacuum oven at 70°C and then proceeds for sintering in horizontal tube furnace with various sintering temperature, a dwell time of 30 min and ramp rate of 5°C/min. The samples were then characterized using field emission scanning electron microscope (FE-SEM) to examine the morphology, X-ray diffraction (XRD) for phase identification, Four Point Probe to measure sheet resistance, and thermogravimetric and differential scanning calorimetry analysis (TGA/DSC) to study the thermal response with respect to temperature. These parameter were studied, the effect of PVA amount (0.10, 0.15, 0.20, 0.30, 0.40, 0.50 g) in Ag-Cu nanopaste formulation was visual inspected, the variation of drying time (20, 30, 40, 60, 80, 100, 120 min) in vacuum oven and sintering temperature (280, 300, 320, 340, 360, 380, 400°C) was recorded. The optimum condition for producing Ag-Cu nanopaste is by using 0.15 g of PVA in the Ag-Cu formulation, 30 min drying time and 340°C sintering temperature.

  17. Age-related differences in the response of leg muscle cross-sectional area and water diffusivity measures to a period of supine rest.

    PubMed

    Lorbergs, Amanda L; Noseworthy, Michael D; MacIntyre, Norma J

    2015-06-01

    The object was to assess whether cross-sectional area (CSA) and water diffusion properties of leg muscles in young and older women change with increased time spent in supine rest. Healthy young (n = 9, aged 20-30 years) and older (n = 9, aged 65-75 years) women underwent MRI scanning of the right leg at baseline, 30 and 60 min of supine rest. Muscle CSA was derived from proton density images. Water diffusion properties [apparent diffusion coefficient (ADC) and fractional anisotropy (FA)] of the tibialis anterior and posterior, soleus, and medial and lateral heads of the gastrocnemius were derived from diffusion tensor imaging (DTI). Repeated measures ANOVAs and Bonferroni post hoc tests determined the effects of time and group on each muscle outcome. In both groups, muscle CSA and FA did not significantly change over time, whereas ADC significantly decreased. A greater decline at 30 min for young women was only observed for ADC in the medial gastrocnemius. Regardless of age, ADC values decreased with fluid shift associated with time spent supine, whereas CSA and FA were not affected. For leg muscle assessment in young and older women, DTI scanning protocols should consider the amount of time spent in a recumbent position.

  18. Electroactive polymer gels based on epoxy resin

    NASA Astrophysics Data System (ADS)

    Samui, A. B.; Jayakumar, S.; Jayalakshmi, C. G.; Pandey, K.; Sivaraman, P.

    2007-04-01

    Five types of epoxy gels have been synthesized from common epoxy resins and hardeners. Fumed silica and nanoclay, respectively, were used as fillers and butyl methacrylate/acrylamide were used as monomer(s) for making interpenetrating polymer networks (IPNs) in three compositions. Swelling study, tensile property evaluation, dynamic mechanical thermal analysis, thermo-gravimetric analysis, scanning electron microscopy and electroactive property evaluation were done. The gels have sufficient mechanical strength and the time taken for bending to 20° was found to be 22 min for forward bias whereas it was just 12 min for reverse bias.

  19. Technical note: how to determine the FDG activity for tumour PET imaging that satisfies European guidelines.

    PubMed

    Koopman, Daniëlle; van Osch, Jochen A C; Jager, Pieter L; Tenbergen, Carlijn J A; Knollema, Siert; Slump, Cornelis H; van Dalen, Jorn A

    2016-12-01

    For tumour imaging with PET, the literature proposes to administer a patient-specific FDG activity that depends quadratically on a patient's body weight. However, a practical approach on how to implement such a protocol in clinical practice is currently lacking. We aimed to provide a practical method to determine a FDG activity formula for whole-body PET examinations that satisfies both the EANM guidelines and this quadratic relation. We have developed a methodology that results in a formula describing the patient-specific FDG activity to administer. A PET study using the NEMA NU-2001 image quality phantom forms the basis of our method. This phantom needs to be filled with 2.0 and 20.0 kBq FDG/mL in the background and spheres, respectively. After a PET acquisition of 10 min, a reconstruction has to be performed that results in sphere recovery coefficients (RCs) that are within the specifications as defined by the EANM Research Ltd (EARL). By performing reconstructions based on shorter scan durations, the minimal scan time per bed position (T min) needs to be extracted using an image coefficient of variation (COV) of 15 %. At T min, the RCs should be within EARL specifications as well. Finally, the FDG activity (in MBq) to administer can be described by [Formula: see text] with c a constant that is typically 0.0533 (MBq/kg(2)), w the patient's body weight (in kg), and t the scan time per bed position that is chosen in a clinical setting (in seconds). We successfully demonstrated this methodology using a state-of-the-art PET/CT scanner. We provide a practical method that results in a formula describing the FDG activity to administer to individual patients for whole-body PET examinations, taking into account both the EANM guidelines and a quadratic relation between FDG activity and patient's body weight. This formula is generally applicable to any PET system, using a specified image reconstruction and scan time per bed position.

  20. Static and dynamic (18) FDG-PET in normal hispaniolan Amazon parrots (Amazona ventralis).

    PubMed

    Souza, Marcy J; Wall, Jonathan S; Stuckey, Alan; Daniel, Gregory B

    2011-01-01

    Positron emission tomography (PET) is often used to stage and monitor human cancer and has recently been used in a similar fashion in veterinary medicine. The most commonly used radiopharmaceutical is 2-Deoxy-2-[(18) F]-Fluoro-d-glucose ((18) F-FDG), which is concentrated and trapped within cells that use glucose as their energy substrate. We characterized the normal distribution of (18) F-FDG in 10 healthy Hispaniolan Amazon parrots (Amazona ventralis) by performing whole body PET scans at steady state, 60min after injection. Significant variability was found in the intestinal activity. Avian species are known to reflux fluid and electrolytes from their cloaca into their colon. To evaluate reflux as the cause of variability in intestinal distribution of (18) F-FDG, dynamic PET scans were performed on the coelomic cavity of six Hispaniolan Amazon parrots from time 0 to 60min postinjection of radiotracer. Reflux of radioactive material from the cloaca into the colon occurred in all birds to varying degrees and occurred before 60min. To evaluate the intestinal tract of clinical avian patients, dynamic scans must be performed starting immediately after injection so that increased radioactivity due to metabolism or hypermetabolic lesions such as cancer can be differentiated from increased radioactivity due to reflux of fluid from the cloaca. © 2010 Veterinary Radiology & Ultrasound.

  1. Extending surgeon response times in tier 2 traumas does not adversely affect patient outcomes.

    PubMed

    Zimmerman, Steven Anthony; Reed, Christopher S; Reed, Alexander N; Jones, Ronald J; Chard, Annette; Reed, Donald N

    2018-06-01

    The presence of a trauma surgeon during patient resuscitations is required at most American College of Surgeons-verified trauma centers despite little evidence showing improved patient outcomes in the less-than-critically injured (Tier 2) trauma patients. This study was designed to identify the impact of extending required surgeon response times on outcomes in tier 2 trauma patients. An American College of Surgeons-verified level 2 trauma center extended the maximum allowed surgeon response time for tier 2 activations from 60 min to 120 min on November 1, 2011. Surgeon response time and patient outcomes of the retrospective control group (January 1, 2008-October 31, 2011) were then compared with the prospective test group (November 1, 2011-December 31, 2014). Primary outcomes included mortality and hospital length of stay (HLOS). Secondary outcomes were emergency department length of stay, and time from ED arrival to CT scan. A subset analysis of all patients evaluated by a surgeon within 60 min of arrival versus those evaluated by a surgeon after 60 min was also performed. The control and test groups were composed of 757 and 792 patients, and their mean injury severity score was 9.0 and 6.0, respectively. Emergency department length of stay showed a statistically significant increase of 12 min, whereas HLOS was unchanged throughout the study. Mortality was not significantly different between the groups. Subset analysis revealed a median surgeon arrival time of 15 min in the <60-min group and 85 min in the >60-min group, whereas the injury severity score, HLOS, and mortality were not significantly different between these subsets. No correlation existed between these outcomes and surgeon arrival time. Doubling required surgeon response time in tier 2 trauma patients does not produce negative outcomes in this patient group. Mandatory surgeon response times in similar patient groups can be re-evaluated to allow for greater flexibility of a limited surgeon workforce while still providing safe care. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Cloud-top structure of tornadic storms on 10 April 1979 from rapid scan and stereo satellite observations

    NASA Technical Reports Server (NTRS)

    Negri, A. J.

    1982-01-01

    Stereoscopic data from near-synchronous eastern and western GOES satellite 3 min interval visible and IR measurements and ground-based radar are used to examine the Wichita Falls, TX tornado of April, 1979. The visible wavelength scan was at 0.6 micron, while the IR was at 11 microns, and additional IR blackbody temperatures were acquired from the Tiros-N spacecraft. A minimum cloud top temperature of 208 K located the point of tornadogenesis. The cloud top cooling rate was determined to be 7 K/21 min above the tropopause preceding the tornado, while a warm area at 221 K developed downwind at the same time. It was found that temperature differences of 10 K can exist between GOES and Tiros-N anvil top measurements, and reach 20 K in the case of a young thunderstorm.

  3. A high stability and repeatability electrochemical scanning tunneling microscope.

    PubMed

    Xia, Zhigang; Wang, Jihao; Hou, Yubin; Lu, Qingyou

    2014-12-01

    We present a home built electrochemical scanning tunneling microscope (ECSTM) with very high stability and repeatability. Its coarse approach is driven by a closely stacked piezo motor of GeckoDrive type with four rigid clamping points, which enhances the rigidity, compactness, and stability greatly. It can give high clarity atomic resolution images without sound and vibration isolations. Its drifting rates in XY and Z directions in solution are as low as 84 pm/min and 59 pm/min, respectively. In addition, repeatable coarse approaches in solution within 2 mm travel distance show a lateral deviation less than 50 nm. The gas environment can be well controlled to lower the evaporation rate of the cell, thus reducing the contamination and elongating the measurement time. Atomically resolved SO4(2-) image on Au (111) work electrode is demonstrated to show the performance of the ECSTM.

  4. Characterizing proton-activated materials to develop PET-mediated proton range verification markers

    NASA Astrophysics Data System (ADS)

    Cho, Jongmin; Ibbott, Geoffrey S.; Kerr, Matthew D.; Amos, Richard A.; Stingo, Francesco C.; Marom, Edith M.; Truong, Mylene T.; Palacio, Diana M.; Betancourt, Sonia L.; Erasmus, Jeremy J.; DeGroot, Patricia M.; Carter, Brett W.; Gladish, Gregory W.; Sabloff, Bradley S.; Benveniste, Marcelo F.; Godoy, Myrna C.; Patil, Shekhar; Sorensen, James; Mawlawi, Osama R.

    2016-06-01

    Conventional proton beam range verification using positron emission tomography (PET) relies on tissue activation alone and therefore requires particle therapy PET whose installation can represent a large financial burden for many centers. Previously, we showed the feasibility of developing patient implantable markers using high proton cross-section materials (18O, Cu, and 68Zn) for in vivo proton range verification using conventional PET scanners. In this technical note, we characterize those materials to test their usability in more clinically relevant conditions. Two phantoms made of low-density balsa wood (~0.1 g cm-3) and beef (~1.0 g cm-3) were embedded with Cu or 68Zn foils of several volumes (10-50 mm3). The metal foils were positioned at several depths in the dose fall-off region, which had been determined from our previous study. The phantoms were then irradiated with different proton doses (1-5 Gy). After irradiation, the phantoms with the embedded foils were moved to a diagnostic PET scanner and imaged. The acquired data were reconstructed with 20-40 min of scan time using various delay times (30-150 min) to determine the maximum contrast-to-noise ratio. The resultant PET/computed tomography (CT) fusion images of the activated foils were then examined and the foils’ PET signal strength/visibility was scored on a 5 point scale by 13 radiologists experienced in nuclear medicine. For both phantoms, the visibility of activated foils increased in proportion to the foil volume, dose, and PET scan time. A linear model was constructed with visibility scores as the response variable and all other factors (marker material, phantom material, dose, and PET scan time) as covariates. Using the linear model, volumes of foils that provided adequate visibility (score 3) were determined for each dose and PET scan time. The foil volumes that were determined will be used as a guideline in developing practical implantable markers.

  5. Novel use of ViewRay MRI guidance for high-dose-rate brachytherapy in the treatment of cervical cancer.

    PubMed

    Ko, Huaising C; Huang, Jessie Y; Miller, Jessica R; Das, Rupak K; Wallace, Charles R; De Costa, Anna-Maria A; Francis, David M; Straub, Margaret R; Anderson, Bethany M; Bradley, Kristin A

    To characterize image quality and feasibility of using ViewRay MRI (VR)-guided brachytherapy planning for cervical cancer. Cervical cancer patients receiving intracavitary brachytherapy with tandem and ovoids, planned using 0.35T VR MRI at our institution, were included in this series. The high-risk clinical target volume (HR-CTV), visible gross tumor volume, bladder, sigmoid, bowel, and rectum contours for each fraction of brachytherapy were evaluated for dosimetric parameters. Typically, five brachytherapy treatments were planned using the T2 sequence on diagnostic MRI for the first and third fractions, and a noncontrast true fast imaging with steady-state precession sequence on VR or CT scan for the remaining fractions. Most patients received 5.5 Gy × 5 fractions using high-dose-rate Ir-192 following 45 Gy of whole-pelvis radiotherapy. The plan was initiated at 5.5 Gy to point A and subsequently optimized and prescribed to the HR-CTV. The goal equivalent dose in 2 Gy fractions for the combined external beam and brachytherapy dose was 85 Gy. Soft-tissue visualization using contrast-to-noise ratios to distinguish normal tissues from tumor at their interface was compared between diagnostic MRI, CT, and VR. One hundred and forty-two fractions of intracavitary brachytherapy were performed from April 2015 to January 2017 on 29 cervical cancer patients, ranging from stages IB1 to IVA. The median HR-CTV was 27.78 cc, with median D 90 HR-CTV of 6.1 Gy. The median time from instrument placement to start of treatment using VR was 65 min (scan time 2 min), compared to 105 min using diagnostic MRI (scan time 11 min) (t-test, p < 0.01). The contrast-to-noise ratio of tumor to cervix in both diagnostic MRI and VR had significantly higher values compared to CT (ANOVA and t-tests, p < 0.01). We report the first clinical use of VR-guided brachytherapy. Time to treatment using this approach was shorter compared to diagnostic MRI. VR also provided significant advantage in visualizing the tumor and cervix compared to CT. This presents a feasible and reliable manner to image and plan gynecologic brachytherapy. Copyright © 2018 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  6. The functional magnetic resonance imaging (fMRI) procedure as experienced by healthy participants and stroke patients--a pilot study.

    PubMed

    Szameitat, André J; Shen, Shan; Sterr, Annette

    2009-07-31

    An important aspect in functional imaging research employing magnetic resonance imaging (MRI) is how participants perceive the MRI scanning itself. For instance, the knowledge of how (un)comfortable MRI scanning is perceived may help institutional review boards (IRBs) or ethics committees to decide on the approval of a study, or researchers to design their experiments. We provide empirical data from our lab gained from 70 neurologically healthy mainly student subjects and from 22 mainly elderly patients suffering from motor deficits after brain damage. All participants took part in various basic research fMRI studies using a 3T MRI scanner. Directly after the scanning, all participants completed a questionnaire assessing their experience with the fMRI procedure. 87.2% of the healthy subjects and 77.3% of the patients rated the MRI procedure as acceptable to comfortable. In healthy subjects, males found the procedure more comfortable, while the opposite was true for patients. 12.1% of healthy subjects considered scanning durations between 30 and 60 min as too long, while no patient considered their 30 min scanning interval as too long. 93.4% of the healthy subjects would like to participate in an fMRI study again, with a significantly lower rate for the subjects who considered the scanning as too long. Further factors, such as inclusion of a diffusion tensor imaging (DTI) scan, age, and study duration had no effect on the questionnaire responses. Of the few negative comments, the main issues were noise, the restriction to keep still for the whole time, and occasional feelings of dizziness. MRI scanning in the basic research setting is an acceptable procedure for elderly and patient participants as well as young healthy subjects.

  7. The functional magnetic resonance imaging (fMRI) procedure as experienced by healthy participants and stroke patients – A pilot study

    PubMed Central

    2009-01-01

    Background An important aspect in functional imaging research employing magnetic resonance imaging (MRI) is how participants perceive the MRI scanning itself. For instance, the knowledge of how (un)comfortable MRI scanning is perceived may help institutional review boards (IRBs) or ethics committees to decide on the approval of a study, or researchers to design their experiments. Methods We provide empirical data from our lab gained from 70 neurologically healthy mainly student subjects and from 22 mainly elderly patients suffering from motor deficits after brain damage. All participants took part in various basic research fMRI studies using a 3T MRI scanner. Directly after the scanning, all participants completed a questionnaire assessing their experience with the fMRI procedure. Results 87.2% of the healthy subjects and 77.3% of the patients rated the MRI procedure as acceptable to comfortable. In healthy subjects, males found the procedure more comfortable, while the opposite was true for patients. 12.1% of healthy subjects considered scanning durations between 30 and 60 min as too long, while no patient considered their 30 min scanning interval as too long. 93.4% of the healthy subjects would like to participate in an fMRI study again, with a significantly lower rate for the subjects who considered the scanning as too long. Further factors, such as inclusion of a diffusion tensor imaging (DTI) scan, age, and study duration had no effect on the questionnaire responses. Of the few negative comments, the main issues were noise, the restriction to keep still for the whole time, and occasional feelings of dizziness. Conclusion MRI scanning in the basic research setting is an acceptable procedure for elderly and patient participants as well as young healthy subjects. PMID:19646238

  8. Early impact of robot-assisted partial nephrectomy on renal function as assessed by renal scintigraphy.

    PubMed

    Luciani, Lorenzo G; Chiodini, Stefano; Donner, Davide; Cai, Tommaso; Vattovani, Valentino; Tiscione, Daniele; Giusti, Guido; Proietti, Silvia; Chierichetti, Franca; Malossini, Gianni

    2016-06-01

    To measure the early impact of robot-assisted partial nephrectomy (RAPN) on renal function as assessed by renal scan (Tc 99m-DTPA), addressing the issue of risk factors for ischemic damage to the kidney. All patients undergoing RAPN for cT1 renal masses between June 2013 and May 2014 were included in this prospective study. Renal function as expressed by glomerular filtration rate (GFR) was assessed by Technetium 99m-diethylenetriaminepentaacetic acid (Tc 99m-DTPA) renal scan preoperatively and postoperatively at 1 month in every patient. A multivariable analysis was used for the determination of independent factors predictive of GFR decrease of the operated kidney. Overall, 32 patients underwent RAPN in the time interval. Median tumor size, blood loss, and ischemia time were 4 cm, 200 mL, and 24 min, respectively. Two grade III complications occurred (postoperative bleeding in the renal fossa, urinoma). The GFR of the operated kidney decreased significantly from 51.7 ± 15.1 mL/min per 1.73 m(2) preoperatively to 40, 12 ± 12.4 mL/min per 1.73 m(2) 1 month postoperatively (p = 0.001) with a decrease of 22.4 %. On multivariable analysis, only tumor size (p = 0.05) was a predictor of GFR decrease of the operated kidney. Robotic-assisted partial nephrectomy had a detectable impact on early renal function in a series of relatively large tumors and prevailing intermediate nephrometric risk. A mean decrease of 22 % of GFR as assessed by renal scan in the operated kidney was found at 1 month postoperatively. In multivariable analysis, tumor size only was a significant predictor of renal function loss.

  9. Single-scan dual-tracer FLT+FDG PET tumor characterization.

    PubMed

    Kadrmas, Dan J; Rust, Thomas C; Hoffman, John M

    2013-02-07

    Rapid multi-tracer PET aims to image two or more tracers in a single scan, simultaneously characterizing multiple aspects of physiology and function without the need for repeat imaging visits. Using dynamic imaging with staggered injections, constraints on the kinetic behavior of each tracer are applied to recover individual-tracer measures from the multi-tracer PET signal. The ability to rapidly and reliably image both (18)F-fluorodeoxyglucose (FDG) and (18)F-fluorothymidine (FLT) would provide complementary measures of tumor metabolism and proliferative activity, with important applications in guiding oncologic treatment decisions and assessing response. However, this tracer combination presents one of the most challenging dual-tracer signal-separation problems--both tracers have the same radioactive half-life, and the injection delay is short relative to the half-life and tracer kinetics. This work investigates techniques for single-scan dual-tracer FLT+FDG PET tumor imaging, characterizing the performance of recovering static and dynamic imaging measures for each tracer from dual-tracer datasets. Simulation studies were performed to characterize dual-tracer signal-separation performance for imaging protocols with both injection orders and injection delays of 10-60 min. Better performance was observed when FLT was administered first, and longer delays before administration of FDG provided more robust signal-separation and recovery of the single-tracer imaging measures. An injection delay of 30 min led to good recovery (R > 0.96) of static image values (e.g. SUV), K(net), and K(1) as compared to values from separate, single-tracer time-activity curves. Recovery of higher order rate parameters (k(2), k(3)) was less robust, indicating that information regarding these parameters was harder to recover in the presence of statistical noise and dual-tracer effects. Performance of the dual-tracer FLT(0 min)+FDG(32 min) technique was further evaluated using PET/CT imaging studies in five patients with primary brain tumors where the data from separate scans of each tracer were combined to synthesize dual-tracer scans with known single-tracer components; results demonstrated similar dual-tracer signal recovery performance. We conclude that rapid dual-tracer FLT+FDG tumor imaging is feasible and can provide quantitative tumor imaging measures comparable to those from conventional separate-scan imaging.

  10. Single-scan dual-tracer FLT+FDG PET tumor characterization

    NASA Astrophysics Data System (ADS)

    Kadrmas, Dan J.; Rust, Thomas C.; Hoffman, John M.

    2013-02-01

    Rapid multi-tracer PET aims to image two or more tracers in a single scan, simultaneously characterizing multiple aspects of physiology and function without the need for repeat imaging visits. Using dynamic imaging with staggered injections, constraints on the kinetic behavior of each tracer are applied to recover individual-tracer measures from the multi-tracer PET signal. The ability to rapidly and reliably image both 18F-fluorodeoxyglucose (FDG) and 18F-fluorothymidine (FLT) would provide complementary measures of tumor metabolism and proliferative activity, with important applications in guiding oncologic treatment decisions and assessing response. However, this tracer combination presents one of the most challenging dual-tracer signal-separation problems—both tracers have the same radioactive half-life, and the injection delay is short relative to the half-life and tracer kinetics. This work investigates techniques for single-scan dual-tracer FLT+FDG PET tumor imaging, characterizing the performance of recovering static and dynamic imaging measures for each tracer from dual-tracer datasets. Simulation studies were performed to characterize dual-tracer signal-separation performance for imaging protocols with both injection orders and injection delays of 10-60 min. Better performance was observed when FLT was administered first, and longer delays before administration of FDG provided more robust signal-separation and recovery of the single-tracer imaging measures. An injection delay of 30 min led to good recovery (R > 0.96) of static image values (e.g. SUV), Knet, and K1 as compared to values from separate, single-tracer time-activity curves. Recovery of higher order rate parameters (k2, k3) was less robust, indicating that information regarding these parameters was harder to recover in the presence of statistical noise and dual-tracer effects. Performance of the dual-tracer FLT(0 min)+FDG(32 min) technique was further evaluated using PET/CT imaging studies in five patients with primary brain tumors where the data from separate scans of each tracer were combined to synthesize dual-tracer scans with known single-tracer components; results demonstrated similar dual-tracer signal recovery performance. We conclude that rapid dual-tracer FLT+FDG tumor imaging is feasible and can provide quantitative tumor imaging measures comparable to those from conventional separate-scan imaging.

  11. Single-scan dual-tracer FLT+FDG PET tumor characterization

    PubMed Central

    Kadrmas, Dan J; Rust, Thomas C; Hoffman, John M

    2013-01-01

    Rapid multi-tracer PET aims to image two or more tracers in a single scan, simultaneously characterizing multiple aspects of physiology and function without the need for repeat imaging visits. Using dynamic imaging with staggered injections, constraints on the kinetic behavior of each tracer are applied to recover individual-tracer measures from the multi-tracer PET signal. The ability to rapidly and reliably image both 18F-fluorodeoxyglucose (FDG) and 18F-fluorothymidine (FLT) would provide complementary measures of tumor metabolism and proliferative activity, with important applications in guiding oncologic treatment decisions and assessing response. However, this tracer combination presents one of the most challenging dual-tracer signal-separation problems—both tracers have the same radioactive half-life, and the injection delay is short relative to the half-life and tracer kinetics. This work investigates techniques for single-scan dual-tracer FLT+FDG PET tumor imaging, characterizing the performance of recovering static and dynamic imaging measures for each tracer from dual-tracer datasets. Simulation studies were performed to characterize dual-tracer signal-separation performance for imaging protocols with both injection orders and injection delays of 10–60 min. Better performance was observed when FLT was administered first, and longer delays before administration of FDG provided more robust signal-separation and recovery of the single-tracer imaging measures. An injection delay of 30 min led to good recovery (R > 0.96) of static image values (e.g. SUV), Knet, and K1 as compared to values from separate, single-tracer time-activity curves. Recovery of higher order rate parameters (k2, k3) was less robust, indicating that information regarding these parameters was harder to recover in the presence of statistical noise and dual-tracer effects. Performance of the dual-tracer FLT(0 min)+FDG(32 min) technique was further evaluated using PET/CT imaging studies in five patients with primary brain tumors where the data from separate scans of each tracer were combined to synthesize dual-tracer scans with known single-tracer components; results demonstrated similar dual-tracer signal recovery performance. We conclude that rapid dual-tracer FLT+FDG tumor imaging is feasible and can provide quantitative tumor imaging measures comparable to those from conventional separate-scan imaging. PMID:23296314

  12. Effects of heating time on the growth and behavior of amorphous carbon nanostructures from ferrocene

    NASA Astrophysics Data System (ADS)

    Rafiqul Islam, Md; Rashid, A. K. M. B.; Ferdous, Md; Shafiul Azam, Md

    2017-05-01

    Heating time is one of the crucial factors in various methods employed for the synthesis of carbon nanostructures (CNSs) from ferrocene. However, the effects of heating time on the growth and morphology of the nanostructured materials has not been well explored yet, particularly for amorphous carbon. Herein, we investigate how the variation of heating time impacts the growth of CNSs by carrying out the reaction between ferrocene and ammonium chloride in a solvent free condition at 250 °C. Several different forms of carbon nanostructures yielded from this reaction at 25 min (CNS-25), 30 min (CNS-30), 35 min (CNS-35) and 40 min (CNS-40) were analyzed by means of field emission scanning electron microscopy (FESEM) coupled with energy-dispersive x-ray (EDX), Fourier transform infrared (FTIR) and ultraviolet-visible (UV-Vis) spectroscopy. The final product CNS-40 was washed several times with concentrated hydrochloric acid solution to remove the impurities and then characterized by the means of similar techniques. FTIR spectra of all the nanostructures confirmed the presence of several functional groups such as C  =  C, C-O and -OH etc, which are common in carbonaceous nanostructures. However, the FESEM images obtained are significantly different and suggest a gradual growth of the carbon nanostructures ending up with long carbon nanotubes after 40 min. No absorption peak in the visible region of the UV-Vis spectra of the final product confirms the amorphous nature, which is also supported by XRD of the synthesized nanotube. Moreover, a noteworthy redshift in the UV-Vis peaks reflecting a huge increase in length and diameter of the nanostructures indicates the maximum longitudinal growth of the carbon nanotubes occurs during 35 min to 40 min.

  13. Effect of Duration of Irrigation with Sodium Hypochlorite in Clinical Protocol of MTAD on Removal of Smear Layer and Creating Dentinal Erosion

    PubMed Central

    Lotfi, Mehrdad; Moghaddam, Negar; Vosoughhosseini, Sepideh; Zand, Vahid; Saghiri, Mohammad Ali

    2012-01-01

    Background and aims The aim of the present study was to compare 1.3% sodium hypochlorite (NaOCl) in MTAD (mixture of tetracycline isomer, acid, and detergent) for the removal of the smear layer and induction of canal erosion. Materials and methods 38 maxillary incisors were divided in three experimental groups of 10 and two positive and negative control groups of each 4 teeth, and prepared using rotary files. In test groups, 1.3% NaOCl was used for 5, 10 and 20 minutes during preparation followed by MTAD as the final rinse. In negative control group, 5.25% NaOCl was used for 10 minutes followed by 17% Ethylenediamine Tetra-Acetic Acid (EDTA) as the final rinse. In positive control group, dis-tilled water was used for 10 minutes during preparation and then as the final rinse. The samples were examined under scan-ning electron microscope, and the smear layer and dentinal erosion scores were recorded. Results Five and 10 min groups had significant differences with 20 min group (p < 0.05). In apical third, 5 and 10 min groups had also significant differences with 20 min (p < 0.05). In the coronal thirds, when the time of irrigation with 1.3% NaOCl increased from 5 min to 20 min, erosion also increased significantly. However, 5 and 10 min groups had no signifi-cant differences with negative control group. Conclusion The use of 1.3% sodium hypochlorite for 5 and 10 minutes in the MTAD protocol removes the smear layer in the coronal and middle thirds but does not induce erosion. PMID:22991642

  14. Comparison of the Delay in Processing Time and Protective Plastic Cases in Two Phosphor Plate Systems

    PubMed Central

    Aktan, Ali Murat; Çiftçi, Mehmet Ertuğrul; Akgünlü, Faruk

    2012-01-01

    Objective. The purpose of this study was to analyze two phosphor plate systems (PSPs) (Dürr Dental, Digora Optime) according to their scanning delay and protective plastic case performances. Methods. Two PSPs using an aluminum step wedge were exposed. These plates were placed in three different protective plastic cases (manufacturers' original cases, black case, and white case) before obtaining the radiographs and were then processed immediately and 1, 5, 10, 30, 60, 120, 240, and 480 min after exposure. Mean gray values (MGVs) of the 3rd, 5th, 7th, and 9th steps of the wedges were compared using ANOVA. Results. Statistically significant differences were found between the two PSPs (P < 0.001). ANOVA revealed that the MGVs of four steps of the wedges were significantly different from each other for all scan delays (P < 0.001). MGVs increased with increasing scanning delay, except the group with Dürr plates in their original cases. Reduction in image quality began 5 min after exposure in the other Dürr plate groups. Conclusions. Within the limitations of the current study, it can be concluded that scanning delay causes a reduction in image quality, and using the manufacturer's original protective case will result in better performance of PSPs. PMID:23213301

  15. Laser power and Scanning Speed Influence on the Mechanical Property of Laser Metal Deposited Titanium-Alloy

    NASA Astrophysics Data System (ADS)

    Mahamood, Rasheedat M.; Akinlabi, Esther T.; Akinlabi, Stephen

    2015-03-01

    The influence of the laser power and the scanning speed on the microhardness of the Laser Metal Deposited Ti6Al4V, an aerospace Titanium-alloy, was studied. Ti6Al4V powder was deposited on the Ti6Al4V substrate using the Laser Metal Deposition (LMD) process, an Additive Manufacturing (AM) manufacturing technology. The laser power was varied between 1.8 kW 3 kW and the scanning speed was varied between 0.05 m/s and 0.1 m/s. The powder flow rate and the gas flow rate were kept at constant values of 2 g/min and 2 l/min respectively. The full factorial design of experiment was used to design the experiment and to also analyze the results in the Design Expert 9 software environment. The microhardness profiling was studied using Microhardness indenter performed at a load of 500 g and at a dwelling time of 15 s. The distance between indentations was maintained at a distance of 15 μm. The study revealed that as the laser power was increased, the microhardness was found to decrease and as the scanning speed was increased, the microhardness was found to also increase. The results are presented and fully discussed.

  16. Comparison of the delay in processing time and protective plastic cases in two phosphor plate systems.

    PubMed

    Aktan, Ali Murat; Ciftçi, Mehmet Ertuğrul; Akgünlü, Faruk

    2012-01-01

    The purpose of this study was to analyze two phosphor plate systems (PSPs) (Dürr Dental, Digora Optime) according to their scanning delay and protective plastic case performances. Two PSPs using an aluminum step wedge were exposed. These plates were placed in three different protective plastic cases (manufacturers' original cases, black case, and white case) before obtaining the radiographs and were then processed immediately and 1, 5, 10, 30, 60, 120, 240, and 480 min after exposure. Mean gray values (MGVs) of the 3rd, 5th, 7th, and 9th steps of the wedges were compared using ANOVA. Statistically significant differences were found between the two PSPs (P < 0.001). ANOVA revealed that the MGVs of four steps of the wedges were significantly different from each other for all scan delays (P < 0.001). MGVs increased with increasing scanning delay, except the group with Dürr plates in their original cases. Reduction in image quality began 5 min after exposure in the other Dürr plate groups. Within the limitations of the current study, it can be concluded that scanning delay causes a reduction in image quality, and using the manufacturer's original protective case will result in better performance of PSPs.

  17. SAR and scan-time optimized 3D whole-brain double inversion recovery imaging at 7T.

    PubMed

    Pracht, Eberhard D; Feiweier, Thorsten; Ehses, Philipp; Brenner, Daniel; Roebroeck, Alard; Weber, Bernd; Stöcker, Tony

    2018-05-01

    The aim of this project was to implement an ultra-high field (UHF) optimized double inversion recovery (DIR) sequence for gray matter (GM) imaging, enabling whole brain coverage in short acquisition times ( ≈5 min, image resolution 1 mm 3 ). A 3D variable flip angle DIR turbo spin echo (TSE) sequence was optimized for UHF application. We implemented an improved, fast, and specific absorption rate (SAR) efficient TSE imaging module, utilizing improved reordering. The DIR preparation was tailored to UHF application. Additionally, fat artifacts were minimized by employing water excitation instead of fat saturation. GM images, covering the whole brain, were acquired in 7 min scan time at 1 mm isotropic resolution. SAR issues were overcome by using a dedicated flip angle calculation considering SAR and SNR efficiency. Furthermore, UHF related artifacts were minimized. The suggested sequence is suitable to generate GM images with whole-brain coverage at UHF. Due to the short total acquisition times and overall robustness, this approach can potentially enable DIR application in a routine setting and enhance lesion detection in neurological diseases. Magn Reson Med 79:2620-2628, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  18. Whole-body computed tomography in trauma patients: optimization of the patient scanning position significantly shortens examination time while maintaining diagnostic image quality.

    PubMed

    Hickethier, Tilman; Mammadov, Kamal; Baeßler, Bettina; Lichtenstein, Thorsten; Hinkelbein, Jochen; Smith, Lucy; Plum, Patrick Sven; Chon, Seung-Hun; Maintz, David; Chang, De-Hua

    2018-01-01

    The study was conducted to compare examination time and artifact vulnerability of whole-body computed tomographies (wbCTs) for trauma patients using conventional or optimized patient positioning. Examination time was measured in 100 patients scanned with conventional protocol (Group A: arms positioned alongside the body for head and neck imaging and over the head for trunk imaging) and 100 patients scanned with optimized protocol (Group B: arms flexed on a chest pillow without repositioning). Additionally, influence of two different scanning protocols on image quality in the most relevant body regions was assessed by two blinded readers. Total wbCT duration was about 35% or 3:46 min shorter in B than in A. Artifacts in aorta (27 vs 6%), liver (40 vs 8%) and spleen (27 vs 5%) occurred significantly more often in B than in A. No incident of non-diagnostic image quality was reported, and no significant differences for lungs and spine were found. An optimized wbCT positioning protocol for trauma patients allows a significant reduction of examination time while still maintaining diagnostic image quality.

  19. Three-dimensional T1 and T2* mapping of human lung parenchyma using interleaved saturation recovery with dual echo ultrashort echo time imaging (ITSR-DUTE).

    PubMed

    Gai, Neville D; Malayeri, Ashkan A; Bluemke, David A

    2017-04-01

    To develop and assess a new technique for three-dimensional (3D) full lung T1 and T2* mapping using a single free breathing scan during a clinically feasible time. A 3D stack of dual-echo ultrashort echo time (UTE) radial acquisition interleaved with and without a WET (water suppression enhanced through T1 effects) saturation pulse was used to map T1 and T2* simultaneously in a single scan. Correction for modulation due to multiple views per segment was derived. Bloch simulations were performed to study saturation pulse excitation profile on lung tissue. Optimization of the saturation delay time (for T1 mapping) and echo time (for T2* mapping) was performed. Monte Carlo simulation was done to predict accuracy and precision of the sequence with signal-to-noise ratio of in vivo images used in the simulation. A phantom study was carried out using the 3D interleaved saturation recovery with dual echo ultrashort echo time imaging (ITSR-DUTE) sequence and reference standard inversion recovery spin echo sequence (IR-SE) to compare accuracy of the sequence. Nine healthy volunteers were imaged and mean (SD) of T1 and T2* in lung parenchyma at 3T were estimated through manually assisted segmentation. 3D lung coverage with a resolution of 2.5 × 2.5 × 6 mm 3 was performed and nominal scan time was recorded for the scans. Repeatability was assessed in three of the volunteers. Regional differences in T1/T2* values were also assessed. The phantom study showed accuracy of T1 values to be within 2.3% of values obtained from IR-SE. Mean T1 value in lung parenchyma was 1002 ± 82 ms while T2* was 0.85 ± 0.1 ms. Scan time was ∼10 min for volunteer scans. Mean coefficient of variation (CV) across slices was 0.057 and 0.09, respectively. Regional variation along the gravitational direction and between right and left lung were not significant (P = 0.25 and P = 0.06, respectively) for T1. T2* showed significant variation (P = 0.03) along the gravitational direction. Repeatability for three volunteers was within 0.7% for T1 and 1.9% for T2*. 3D T1 and T2* maps of the entire lung can be obtained in a single scan of ∼10 min with a resolution of 2.5 × 2.5 × 6 mm 3 . 2 J. Magn. Reson. Imaging 2017;45:1097-1104. 2016 International Society for Magnetic Resonance in Medicine.

  20. Assessing Variations in Areal Organization for the Intrinsic Brain: From Fingerprints to Reliability

    PubMed Central

    Xu, Ting; Opitz, Alexander; Craddock, R. Cameron; Wright, Margaret J.; Zuo, Xi-Nian; Milham, Michael P.

    2016-01-01

    Resting state fMRI (R-fMRI) is a powerful in-vivo tool for examining the functional architecture of the human brain. Recent studies have demonstrated the ability to characterize transitions between functionally distinct cortical areas through the mapping of gradients in intrinsic functional connectivity (iFC) profiles. To date, this novel approach has primarily been applied to iFC profiles averaged across groups of individuals, or in one case, a single individual scanned multiple times. Here, we used a publically available R-fMRI dataset, in which 30 healthy participants were scanned 10 times (10 min per session), to investigate differences in full-brain transition profiles (i.e., gradient maps, edge maps) across individuals, and their reliability. 10-min R-fMRI scans were sufficient to achieve high accuracies in efforts to “fingerprint” individuals based upon full-brain transition profiles. Regarding test–retest reliability, the image-wise intraclass correlation coefficient (ICC) was moderate, and vertex-level ICC varied depending on region; larger durations of data yielded higher reliability scores universally. Initial application of gradient-based methodologies to a recently published dataset obtained from twins suggested inter-individual variation in areal profiles might have genetic and familial origins. Overall, these results illustrate the utility of gradient-based iFC approaches for studying inter-individual variation in brain function. PMID:27600846

  1. An ultrahigh vacuum fast-scanning and variable temperature scanning tunneling microscope for large scale imaging.

    PubMed

    Diaconescu, Bogdan; Nenchev, Georgi; de la Figuera, Juan; Pohl, Karsten

    2007-10-01

    We describe the design and performance of a fast-scanning, variable temperature scanning tunneling microscope (STM) operating from 80 to 700 K in ultrahigh vacuum (UHV), which routinely achieves large scale atomically resolved imaging of compact metallic surfaces. An efficient in-vacuum vibration isolation and cryogenic system allows for no external vibration isolation of the UHV chamber. The design of the sample holder and STM head permits imaging of the same nanometer-size area of the sample before and after sample preparation outside the STM base. Refractory metal samples are frequently annealed up to 2000 K and their cooldown time from room temperature to 80 K is 15 min. The vertical resolution of the instrument was found to be about 2 pm at room temperature. The coarse motor design allows both translation and rotation of the scanner tube. The total scanning area is about 8 x 8 microm(2). The sample temperature can be adjusted by a few tens of degrees while scanning over the same sample area.

  2. Simplifying [18F]GE-179 PET: are both arterial blood sampling and 90-min acquisitions essential?

    PubMed

    McGinnity, Colm J; Riaño Barros, Daniela A; Trigg, William; Brooks, David J; Hinz, Rainer; Duncan, John S; Koepp, Matthias J; Hammers, Alexander

    2018-06-11

    The NMDA receptor radiotracer [ 18 F]GE-179 has been used with 90-min scans and arterial plasma input functions. We explored whether (1) arterial blood sampling is avoidable and (2) shorter scans are feasible. For 20 existing [ 18 F]GE-179 datasets, we generated (1) standardised uptake values (SUVs) over eight intervals; (2) volume of distribution (V T ) images using population-based input functions (PBIFs), scaled using one parent plasma sample; and (3) V T images using three shortened datasets, using the original parent plasma input functions (ppIFs). Correlations with the original ppIF-derived 90-min V T s increased for later interval SUVs (maximal ρ = 0.78; 80-90 min). They were strong for PBIF-derived V T s (ρ = 0.90), but between-subject coefficient of variation increased. Correlations were very strong for the 60/70/80-min original ppIF-derived V T s (ρ = 0.97-1.00), which suffered regionally variant negative bias. Where arterial blood sampling is available, reduction of scan duration to 60 min is feasible, but with negative bias. The performance of SUVs was more consistent across participants than PBIF-derived V T s.

  3. X-Band Rapid-Scan Electron Paramagnetic Resonance of Radiation-Induced Defects in Tooth Enamel

    PubMed Central

    Yu, Zhelin; Romanyukha, Alexander; Eaton, Sandra S.; Eaton, Gareth R.

    2015-01-01

    X-band rapid-scan electron paramagnetic resonance (EPR) spectra from tooth enamel samples irradiated with doses of 0.5, 1 and 10 Gy had substantially improved signal-to-noise relative to conventional continuous wave EPR. The radiation-induced signal in 60 mg of a tooth enamel sample irradiated with a 0.5 Gy dose was readily characterized in spectra recorded with 34 min data acquisition times. The coefficient of variance of the calculated dose for a 1 Gy irradiated sample, based on simulation of the first-derivative spectra for three replicates as the sum of native and radiation-induced signals, was 3.9% for continuous wave and 0.4% for rapid scan. PMID:26207683

  4. Time to cranial computerised tomography for acute traumatic brain injury in paediatric patients: Effect of the shorter stays in emergency departments target in New Zealand.

    PubMed

    Jones, Peter G; Kool, Bridget; Dalziel, Stuart; Shepherd, Michael; Le Fevre, James; Harper, Alana; Wells, Susan; Stewart, Joanna; Curtis, Elana; Reid, Papaarangi; Ameratunga, Shanthi

    2017-07-01

    Timely access to computerised tomography (CT) for acute traumatic brain injuries (TBIs) facilitates rapid diagnosis and surgical intervention. In 2009, New Zealand introduced a mandatory target for emergency department (ED) stay such that 95% of patients should leave ED within 6 h of arrival. This study investigated whether this target influenced the timeliness of cranial CT scanning in children who presented to ED with acute TBI. We retrospectively reviewed a random sample of charts of children <15 years with acute TBI from 2006 to 2012. Cases were identified using International Classification of Disease 10 codes consistent with TBI. General linear models investigated changes in time to CT and other indicators before and after the shorter stays in ED target was introduced in 2009. Among the 190 cases eligible for study (n = 91 pre-target and n = 99 post-target), no significant difference was found in time to CT scan pre- and post-target: least squares mean (LSM) with 95% confidence interval = 68 (56-81) versus 65 (53-78) min, respectively, P = 0.66. Time to neurosurgery (LSM 8.7 (5-15) vs. 5.1 (2.6-9.9) h, P = 0.19, or hospital length of stay (LSM: 4.9 (3.9-6.3) vs. 5.2 (4.1-6.7) days, P = 0.69) did not change significantly. However, ED length of stay decreased by 45 min in the post-target period (LSM = 211 (187-238) vs. 166 (98-160) min, P = 0.006). Implementation of the shorter stays in ED target was not associated with a change in the time to CT for children presenting with acute TBI, but an overall reduction in the time spent in ED was apparent. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  5. Clinical evaluation of atlas and deep learning based automatic contouring for lung cancer.

    PubMed

    Lustberg, Tim; van Soest, Johan; Gooding, Mark; Peressutti, Devis; Aljabar, Paul; van der Stoep, Judith; van Elmpt, Wouter; Dekker, Andre

    2018-02-01

    Contouring of organs at risk (OARs) is an important but time consuming part of radiotherapy treatment planning. The aim of this study was to investigate whether using institutional created software-generated contouring will save time if used as a starting point for manual OAR contouring for lung cancer patients. Twenty CT scans of stage I-III NSCLC patients were used to compare user adjusted contours after an atlas-based and deep learning contour, against manual delineation. The lungs, esophagus, spinal cord, heart and mediastinum were contoured for this study. The time to perform the manual tasks was recorded. With a median time of 20 min for manual contouring, the total median time saved was 7.8 min when using atlas-based contouring and 10 min for deep learning contouring. Both atlas based and deep learning adjustment times were significantly lower than manual contouring time for all OARs except for the left lung and esophagus of the atlas based contouring. User adjustment of software generated contours is a viable strategy to reduce contouring time of OARs for lung radiotherapy while conforming to local clinical standards. In addition, deep learning contouring shows promising results compared to existing solutions. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  6. Investigation of Image Reconstruction Parameters of the Mediso nanoScan PC Small-Animal PET/CT Scanner for Two Different Positron Emitters Under NEMA NU 4-2008 Standards.

    PubMed

    Gaitanis, Anastasios; Kastis, George A; Vlastou, Elena; Bouziotis, Penelope; Verginis, Panayotis; Anagnostopoulos, Constantinos D

    2017-08-01

    The Tera-Tomo 3D image reconstruction algorithm (a version of OSEM), provided with the Mediso nanoScan® PC (PET8/2) small-animal positron emission tomograph (PET)/x-ray computed tomography (CT) scanner, has various parameter options such as total level of regularization, subsets, and iterations. Also, the acquisition time in PET plays an important role. This study aims to assess the performance of this new small-animal PET/CT scanner for different acquisition times and reconstruction parameters, for 2-deoxy-2-[ 18 F]fluoro-D-glucose ([ 18 F]FDG) and Ga-68, under the NEMA NU 4-2008 standards. Various image quality metrics were calculated for different realizations of [ 18 F]FDG and Ga-68 filled image quality (IQ) phantoms. [ 18 F]FDG imaging produced improved images over Ga-68. The best compromise for the optimization of all image quality factors is achieved for at least 30 min acquisition and image reconstruction with 52 iteration updates combined with a high regularization level. A high regularization level at 52 iteration updates and 30 min acquisition time were found to optimize most of the figures of merit investigated.

  7. Initial evaluation of the Celesteion large-bore PET/CT scanner in accordance with the NEMA NU2-2012 standard and the Japanese guideline for oncology FDG PET/CT data acquisition protocol version 2.0.

    PubMed

    Kaneta, Tomohiro; Ogawa, Matsuyoshi; Motomura, Nobutoku; Iizuka, Hitoshi; Arisawa, Tetsu; Hino-Shishikura, Ayako; Yoshida, Keisuke; Inoue, Tomio

    2017-10-11

    The goal of this study was to evaluate the performance of the Celesteion positron emission tomography/computed tomography (PET/CT) scanner, which is characterized by a large-bore and time-of-flight (TOF) function, in accordance with the NEMA NU-2 2012 standard and version 2.0 of the Japanese guideline for oncology fluorodeoxyglucose PET/CT data acquisition protocol. Spatial resolution, sensitivity, count rate characteristic, scatter fraction, energy resolution, TOF timing resolution, and image quality were evaluated according to the NEMA NU-2 2012 standard. Phantom experiments were performed using 18 F-solution and an IEC body phantom of the type described in the NEMA NU-2 2012 standard. The minimum scanning time required for the detection of a 10-mm hot sphere with a 4:1 target-to-background ratio, the phantom noise equivalent count (NEC phantom ), % background variability (N 10mm ), % contrast (Q H,10mm ), and recovery coefficient (RC) were calculated according to the Japanese guideline. The measured spatial resolution ranged from 4.5- to 5-mm full width at half maximum (FWHM). The sensitivity and scatter fraction were 3.8 cps/kBq and 37.3%, respectively. The peak noise-equivalent count rate was 70 kcps in the presence of 29.6 kBq mL -1 in the phantom. The system energy resolution was 12.4% and the TOF timing resolution was 411 ps at FWHM. Minimum scanning times of 2, 7, 6, and 2 min per bed position, respectively, are recommended for visual score, noise-equivalent count (NEC) phantom , N 10mm , and the Q H,10mm to N 10mm ratio (QNR) by the Japanese guideline. The RC of a 10-mm-diameter sphere was 0.49, which exceeded the minimum recommended value. The Celesteion large-bore PET/CT system had low sensitivity and NEC, but good spatial and time resolution when compared to other PET/CT scanners. The QNR met the recommended values of the Japanese guideline even at 2 min. The Celesteion is therefore thought to provide acceptable image quality with 2 min/bed position acquisition, which is the most common scan protocol in Japan.

  8. Temperature measurements during laser skin welding

    NASA Astrophysics Data System (ADS)

    Fried, Nathaniel M.; Choi, Bernard; Welch, Ashley J.; Walsh, Joseph T., Jr.

    1999-06-01

    A thermal camera was used to measure surface temperatures during laser skin welding to provide feedback for optimization of the laser parameters. Two-cm-long, full- thickness incisions were made in guinea pig skin. India ink was used as an absorber. Continuous-wave, 1.06-μm, Nd:YAG laser radiation was scanned over the incisions, producing a pulse duration of approximately 100 ms. Cooling durations between scans of 1.6, 4.0, and 8.0 s were studied with total operation times of 3, 5, and 10 min, respectively. A laser spot diameter of 5 mm was used with the power constant at 10 W. Thermal images were obtained at 30 frames per second with a thermal camera detecting 3.5 micrometers radiation. Surface temperatures were recorded at 0, 1, and 6 mm from the center line of the incision. Cooling durations between scans of 1.6 s and 4.0 s in vitro resulted in temperatures at the weld site remaining above ~65°C for prolonged periods of time. Cooling durations between scans as long as 8.0 s were sufficient both in vitro and in vivo to prevent a significant rise in baseline temperatures at the weld site over time.

  9. Optimal acquisition and modeling parameters for accurate assessment of low Ktrans blood-brain barrier permeability using dynamic contrast-enhanced MRI.

    PubMed

    Barnes, Samuel R; Ng, Thomas S C; Montagne, Axel; Law, Meng; Zlokovic, Berislav V; Jacobs, Russell E

    2016-05-01

    To determine optimal parameters for acquisition and processing of dynamic contrast-enhanced MRI (DCE-MRI) to detect small changes in near normal low blood-brain barrier (BBB) permeability. Using a contrast-to-noise ratio metric (K-CNR) for Ktrans precision and accuracy, the effects of kinetic model selection, scan duration, temporal resolution, signal drift, and length of baseline on the estimation of low permeability values was evaluated with simulations. The Patlak model was shown to give the highest K-CNR at low Ktrans . The Ktrans transition point, above which other models yielded superior results, was highly dependent on scan duration and tissue extravascular extracellular volume fraction (ve ). The highest K-CNR for low Ktrans was obtained when Patlak model analysis was combined with long scan times (10-30 min), modest temporal resolution (<60 s/image), and long baseline scans (1-4 min). Signal drift as low as 3% was shown to affect the accuracy of Ktrans estimation with Patlak analysis. DCE acquisition and modeling parameters are interdependent and should be optimized together for the tissue being imaged. Appropriately optimized protocols can detect even the subtlest changes in BBB integrity and may be used to probe the earliest changes in neurodegenerative diseases such as Alzheimer's disease and multiple sclerosis. © 2015 Wiley Periodicals, Inc.

  10. GPU-based cone beam computed tomography.

    PubMed

    Noël, Peter B; Walczak, Alan M; Xu, Jinhui; Corso, Jason J; Hoffmann, Kenneth R; Schafer, Sebastian

    2010-06-01

    The use of cone beam computed tomography (CBCT) is growing in the clinical arena due to its ability to provide 3D information during interventions, its high diagnostic quality (sub-millimeter resolution), and its short scanning times (60 s). In many situations, the short scanning time of CBCT is followed by a time-consuming 3D reconstruction. The standard reconstruction algorithm for CBCT data is the filtered backprojection, which for a volume of size 256(3) takes up to 25 min on a standard system. Recent developments in the area of Graphic Processing Units (GPUs) make it possible to have access to high-performance computing solutions at a low cost, allowing their use in many scientific problems. We have implemented an algorithm for 3D reconstruction of CBCT data using the Compute Unified Device Architecture (CUDA) provided by NVIDIA (NVIDIA Corporation, Santa Clara, California), which was executed on a NVIDIA GeForce GTX 280. Our implementation results in improved reconstruction times from minutes, and perhaps hours, to a matter of seconds, while also giving the clinician the ability to view 3D volumetric data at higher resolutions. We evaluated our implementation on ten clinical data sets and one phantom data set to observe if differences occur between CPU and GPU-based reconstructions. By using our approach, the computation time for 256(3) is reduced from 25 min on the CPU to 3.2 s on the GPU. The GPU reconstruction time for 512(3) volumes is 8.5 s. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  11. Interest of intra-operative 3D imaging in spine surgery: a prospective randomized study.

    PubMed

    Ruatti, Sébastien; Dubois, C; Chipon, E; Kerschbaumer, G; Milaire, M; Moreau-Gaudry, A; Tonetti, J; Merloz, Ph

    2016-06-01

    We report a single-center, prospective, randomized study for pedicle screw insertion in opened and percutaneous spine surgeries, using a computer-assisted surgery (CAS) technique with three-dimensional (3D) intra-operative images intensifier (without planification on pre-operative CT scan) vs conventional surgical procedure. We included 143 patients: Group C (conventional, 72 patients) and Group N (3D Fluoronavigation, 71 patients). We measured the pedicle screw running time, and surgeon's radiation exposure. All pedicle runs were assessed according to Heary by two independent radiologists on a post-operative CT scan. 3D Fluoronavigation appeared less accurate in percutaneous procedures (24 % of misplaced pedicle screws vs 5 % in Group C) (p = 0.007), but more accurate in opened surgeries (5 % of misplaced pedicle screws vs 17 % in Group C) (p = 0.025). For one vertebra, the average surgical running time reached 8 min in Group C vs 21 min in Group N for percutaneous surgeries (p = 3.42 × 10(-9)), 7.33 min in Group C vs 16.33 min in Group N (p = 2.88 × 10(-7)) for opened surgeries. The 3D navigation device delivered less radiation in percutaneous procedures [0.6 vs 1.62 mSv in Group C (p = 2.45 × 10(-9))]. For opened surgeries, it was twice higher in Group N with 0.21 vs 0.1 mSv in Group C (p = 0.022). The rate of misplaced pedicle screws with conventional techniques was nearly the same as most papers and a little bit higher with CAS. Surgical running time and radiation exposure were consistent with many studies. Our work hypothesis is partially confirmed, depending on the type of surgery (opened or closed procedure).

  12. Carbon-Ion Pencil Beam Scanning Treatment With Gated Markerless Tumor Tracking: An Analysis of Positional Accuracy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mori, Shinichiro, E-mail: shinshin@nirs.go.jp; Karube, Masataka; Shirai, Toshiyuki

    Purpose: Having implemented amplitude-based respiratory gating for scanned carbon-ion beam therapy, we sought to evaluate its effect on positional accuracy and throughput. Methods and Materials: A total of 10 patients with tumors of the lung and liver participated in the first clinical trials at our center. Treatment planning was conducted with 4-dimensional computed tomography (4DCT) under free-breathing conditions. The planning target volume (PTV) was calculated by adding a 2- to 3-mm setup margin outside the clinical target volume (CTV) within the gating window. The treatment beam was on when the CTV was within the PTV. Tumor position was detected inmore » real time with a markerless tumor tracking system using paired x-ray fluoroscopic imaging units. Results: The patient setup error (mean ± SD) was 1.1 ± 1.2 mm/0.6 ± 0.4°. The mean internal gating accuracy (95% confidence interval [CI]) was 0.5 mm. If external gating had been applied to this treatment, the mean gating accuracy (95% CI) would have been 4.1 mm. The fluoroscopic radiation doses (mean ± SD) were 23.7 ± 21.8 mGy per beam and less than 487.5 mGy total throughout the treatment course. The setup, preparation, and irradiation times (mean ± SD) were 8.9 ± 8.2 min, 9.5 ± 4.6 min, and 4.0 ± 2.4 min, respectively. The treatment room occupation time was 36.7 ± 67.5 min. Conclusions: Internal gating had a much higher accuracy than external gating. By the addition of a setup margin of 2 to 3 mm, internal gating positional error was less than 2.2 mm at 95% CI.« less

  13. Resolution enhancement in in vivo NMR spectroscopy: detection of intermolecular zero-quantum coherences

    NASA Astrophysics Data System (ADS)

    Faber, Cornelius; Pracht, Eberhard; Haase, Axel

    2003-04-01

    Intermolecular zero-quantum coherences are insensitive to magnetic field inhomogeneities. For this reason we have applied the HOMOGENIZED sequence [Vathyam et al., Science 272 (1996) 92] to phantoms containing metabolites at low concentrations, phantoms with air inclusions, an intact grape, and the head of a rat in vivo at 750 MHz. In the 1H-spectra, the water signal is efficiently suppressed and line broadening due to susceptibility gradients is effectively removed along the indirectly detected dimension. We have obtained a 1H-spectrum of a 2.5 mM solution of γ-aminobutyric acid in 12 min scan time. In the phantom with air inclusions a reduction of line widths from 0.48 ppm in the direct dimension to 0.07 ppm in the indirect dimension was observed, while in a deshimmed grape the reduction was from 1.4 to 0.07 ppm. In a spectrum of the grape we were able to resolve glucose resonances at 0.3 ppm from the water in 6 min scan time. J-coupling information was partly retained. In the in vivo spectra of the rat brain five major metabolites were observed.

  14. Preparation and characterization of RuO2/polypyrrole electrodes for supercapacitors

    NASA Astrophysics Data System (ADS)

    Li, Xiang; Wu, Yujiao; Zheng, Feng; Ling, Min; Lu, Fanghai

    2014-11-01

    Polypyrrole (PPy) embedded RuO2 electrodes were prepared by the composite method. Precursor solution of RuO2 was coated on tantalum sheet and annealed at 260 °C for 2.5 h to develop a thin film. PPy particles were deposited on RuO2 films and dried at 80 °C for 12 h to form composite electrode. Microstructure and morphology of RuO2/PPy electrode were characterized using Fourier transform infrared spectrometer, X-ray diffraction and scanning electron microscopy, respectively. Our results confirmed that counter ions are incorporated into RuO2 matrix. Structure of the composite with amorphous phase was verified by X-ray diffraction. Analysis by scanning electron microscopy reveals that during grain growth of RuO2/PPy, PPy particle size sharply increases as deposition time is over 20 min. Electrochemical properties of RuO2/PPy electrode were calculated using cyclic voltammetry. As deposition times of PPy are 10, 20, 25 and 30 min, specific capacitances of composite electrodes reach 657, 553, 471 and 396 F g-1, respectively. Cyclic behaviors of RuO2/PPy composite electrodes are stable.

  15. A wearable bluetooth LE sensor for patient monitoring during MRI scans.

    PubMed

    Vogt, Christian; Reber, Jonas; Waltisberg, Daniel; Buthe, Lars; Marjanovic, Josip; Munzenrieder, Niko; Pruessmann, Klaas P; Troster, Gerhard

    2016-08-01

    This paper presents a working prototype of a wearable patient monitoring device capable of recording the heart rate, blood oxygen saturation, surface temperature and humidity during an magnetic resonance imaging (MRI) experiment. The measured values are transmitted via Bluetooth low energy (LE) and displayed in real time on a smartphone on the outside of the MRI room. During 7 MRI image acquisitions of at least 1 min and a total duration of 25 min no Bluetooth data packets were lost. The raw measurements of the light intensity for the photoplethysmogram based heart rate measurement shows an increased noise floor by 50LSB (least significant bit) during the MRI operation, whereas the temperature and humidity readings are unaffected. The device itself creates a magnetic resonance (MR) signal loss with a radius of 14 mm around the device surface and shows no significant increase in image noise of an acquired MRI image due to its radio frequency activity. This enables continuous and unobtrusive patient monitoring during MRI scans.

  16. Long Duration X-ray Bursts Observed by MAXI

    NASA Astrophysics Data System (ADS)

    Serino, Motoko; Iwakiri, Wataru; Tamagawa, Toru; Sakamoto, Takanori; Nakahira, Satoshi; Matsuoka, Masaru; Yamaoka, Kazutaka; Negoro, Hitoshi

    Monitor of All-sky X-ray Image (MAXI) is X-ray mission on the International Space Station. MAXI scans all sky every 92 min and detects various X-ray transient events including X-ray bursts. Among the X-ray bursts observed by MAXI, eleven had long duration and were observed more than one scan. Six out of eleven long bursts have the e-folding time of >1 h, that should be classified as "superbursts", while the rest are "intermediate-duration bursts". The total emitted energy of these long X-ray bursts range from 1041 to 1042 ergs. The lower limits of the superburst recurrence time of 4U 0614+091 and Ser X-1 are calculated as 4400 and 59 days, which may be consistent with the observed recurrence time of 3523 and 1148 days, respectively.

  17. A new fast and fully automated software based algorithm for extracting respiratory signal from raw PET data and its comparison to other methods.

    PubMed

    Kesner, Adam Leon; Kuntner, Claudia

    2010-10-01

    Respiratory gating in PET is an approach used to minimize the negative effects of respiratory motion on spatial resolution. It is based on an initial determination of a patient's respiratory movements during a scan, typically using hardware based systems. In recent years, several fully automated databased algorithms have been presented for extracting a respiratory signal directly from PET data, providing a very practical strategy for implementing gating in the clinic. In this work, a new method is presented for extracting a respiratory signal from raw PET sinogram data and compared to previously presented automated techniques. The acquisition of respiratory signal from PET data in the newly proposed method is based on rebinning the sinogram data into smaller data structures and then analyzing the time activity behavior in the elements of these structures. From this analysis, a 1D respiratory trace is produced, analogous to a hardware derived respiratory trace. To assess the accuracy of this fully automated method, respiratory signal was extracted from a collection of 22 clinical FDG-PET scans using this method, and compared to signal derived from several other software based methods as well as a signal derived from a hardware system. The method presented required approximately 9 min of processing time for each 10 min scan (using a single 2.67 GHz processor), which in theory can be accomplished while the scan is being acquired and therefore allowing a real-time respiratory signal acquisition. Using the mean correlation between the software based and hardware based respiratory traces, the optimal parameters were determined for the presented algorithm. The mean/median/range of correlations for the set of scans when using the optimal parameters was found to be 0.58/0.68/0.07-0.86. The speed of this method was within the range of real-time while the accuracy surpassed the most accurate of the previously presented algorithms. PET data inherently contains information about patient motion; information that is not currently being utilized. We have shown that a respiratory signal can be extracted from raw PET data in potentially real-time and in a fully automated manner. This signal correlates well with hardware based signal for a large percentage of scans, and avoids the efforts and complications associated with hardware. The proposed method to extract a respiratory signal can be implemented on existing scanners and, if properly integrated, can be applied without changes to routine clinical procedures.

  18. [Brushing abrasion of the enamel surface after erosion].

    PubMed

    Lipei, Chen; Xiangke, Ci; Xiaoyan, Ou

    2017-08-01

    Objective A study was conducted to compare the effect of different enamel remineralization periods after erosion on the depth of brushing abrasion. Methods Ten volunteers were selected for a 4-day experiment. A total of 60 enamels were randomly assigned into six groups (A-F) and placed in intraoral palatal devices. On the first day, the palatal devices were placed in oral cavity (24 h) . On the following three days, brushing experiments were performed extraorally, two times per day. The specific experimental method of brushing follows these next steps. First, the group F specimens were covered with a film of wax, and then acid etched for 2 min. Subsequently, the film of wax was detached. The groups from A to D were brushed after remineralization at the following time intervals: group A, 0 min; group B, 20 min; group C, 40 min; group D, 60 min. Erosion and remineralization were performed on group E, but without brushing. Remineralization was performed on group F, but without acid etching and brushing. The depth of enamel abrasion was determined by a mechanical profilometer. The surface morphology of the enamel blocks was observed using a scanning electron microscope. Results 1) The depth of abrasion was different in varied enamel remineralization time after acid etching. The statistical significant differences between groups were as follows. 2) When the time of enamel remineralization after acid etching was short, the surface depression in the electron microscope was deep, and the surface morphology was rough. Conclusion Brushing immediately after acid etching would cause much serious abrasion to the enamel surface. Brushing after 60 min can effectively reduce the abrasion of acid etching enamel.

  19. Microwave-assisted extraction of total bioactive saponin fraction from Gymnema sylvestre with reference to gymnemagenin: a potential biomarker.

    PubMed

    Mandal, Vivekananda; Dewanjee, Saikat; Mandal, Subhash C

    2009-01-01

    To develop a fast and ecofriendly microwave assisted extraction (MAE) technique for the effective and exhaustive extraction of gymnemagenin as an indicative biomarker for the quality control of Gymnema sylvestre. Several extraction parameters such as microwave power, extraction time, solvent composition, pre-leaching time, loading ratio and extraction cycle were studied for the determination of the optimum extraction condition. Scanning electron micrographs were obtained to elucidate the mechanism of extraction. The final optimum extraction conditions as obtained from the study were: 40% microwave power, 6 min irradiation time, 85% v/v methanol as the extraction solvent, 15 min pre-leaching time and 25 : 1 (mL/g) as the solvent-to-material loading ratio. The proposed extraction technique produced a maximum yield of 4.3% w/w gymnemagenin in 6 min which was 1.3, 2.5 and 1.95 times more efficient than 6 h of heat reflux, 24 h of maceration and stirring extraction, respectively. A synergistic heat and mass transfer theory was also proposed to support the extraction mechanism. Comparison with conventional extraction methods revealed that MAE could save considerable amounts of time and energy, whilst the reduction of volume of organic solvent consumed provides an ecofriendly feature.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howard, M; Beltran, C; Herman, M

    Purpose: To investigate the influence of the minimum monitor unit (MU) on the quality of clinical treatment plans for scanned proton therapy. Methods: Delivery system characteristics limit the minimum number of protons that can be delivered per spot, resulting in a min-MU limit. Plan quality can be impacted by the min-MU limit. Two sites were used to investigate the impact of min-MU on treatment plans: pediatric brain tumor at a depth of 5-10 cm; a head and neck tumor at a depth of 1-20 cm. Three field intensity modulated spot scanning proton plans were created for each site with themore » following parameter variations: min-MU limit range of 0.0000-0.0060; and spot spacing range of 0.5-2.0σ of the nominal spot size at isocenter in water (σ=4mm in this work). Comparisons were based on target homogeneity and normal tissue sparing. Results: The increase of the min-MU with a fixed spot spacing decreases plan quality both in homogeneous target coverage and in the avoidance of critical structures. Both head and neck and pediatric brain plans show a 20% increase in relative dose for the hot spot in the CTV and 10% increase in key critical structures when comparing min-MU limits of 0.0000 and 0.0060 with a fixed spot spacing of 1σ. The DVHs of CTVs show min-MU limits of 0.0000 and 0.0010 produce similar plan quality and quality decreases as the min-MU limit increases beyond 0.0020. As spot spacing approaches 2σ, degradation in plan quality is observed when no min-MU limit is imposed. Conclusion: Given a fixed spot spacing of ≤ 1σ of the spot size in water, plan quality decreases as min- MU increases greater than 0.0020. The effect of min-MU should be taken into consideration while planning spot scanning proton therapy treatments to realize its full potential.« less

  1. Operating parameters effect on physico-chemical characteristics of nanocrystalline apatite coatings electrodeposited on 316L stainless steel

    NASA Astrophysics Data System (ADS)

    Pham, Thi Nam; Thanh Dinh, Thi Mai; Thom Nguyen, Thi; Phuong Nguyen, Thu; Kergourlay, E.; Grossin, D.; Bertrand, G.; Pebere, N.; Marcelin, S. J.; Charvillat, C.; Drouet, C.

    2017-09-01

    Hydroxyapatite (HAp) was known as a bone implant material due to its biocompatibility, bioactive, chemical stability and its compositional similarity to natural bone. In this work nanocrystalline HAp coatings were prepared on 316L stainless steel (316LSS) substrates using a potentio-dynamic method (potential scanning in the range from 0 to  -1.6 V/SCE) in the presence of dissolved 3  ×  10-2 M Ca(NO3)2  +  1.8  ×  10-2 M NH4H2PO4  +  0.15 M NaNO3 and 6% H2O2 (w/w). We report the influence of experimental conditions such as temperature (25 °C-60 °C), scanning rate (1 mV s-1-10 mV s-1) and scanning times (1 times-7 times) on the morphology, structure and composition of the HAp coatings by FTIR, XRD and SEM analysis. The results show that the morphology and purity of the HAp coating were greatly affected by temperature, scanning rate and reaction time with rate of 5 mV s-1, reaction time of 26.67 min (corresponding 5 scanning times) and 25 °C, giving better coatings. The in vivo test results after 3 months grafting on femur of dogs of HAp/316LSS material showed that: the material did not induce any osteitis, osteomyelitis or structural abnormalities. The osteitis and osteomyelitis were not observed in microscopy images.

  2. Initial Evaluation of an Adenosine A2A Receptor Ligand, 11C-Preladenant, in Healthy Human Subjects.

    PubMed

    Sakata, Muneyuki; Ishibashi, Kenji; Imai, Masamichi; Wagatsuma, Kei; Ishii, Kenji; Zhou, Xiaoyun; de Vries, Erik F J; Elsinga, Philip H; Ishiwata, Kiichi; Toyohara, Jun

    2017-09-01

    11 C-preladenant is a selective antagonist for mapping of cerebral adenosine A 2A receptors (A 2A Rs) by PET. This is a first-in-human study to examine the safety, radiation dosimetry, and brain imaging of 11 C-preladenant in healthy human subjects. Methods: Dynamic 11 C-preladenant PET scans (90 min) were obtained in 5 healthy male subjects. During the scan, arterial blood was sampled at various time intervals, and the fraction of the parent compound in plasma was determined. For anatomic coregistration, T1-weighted MRI was performed. The total distribution volume ( V T ) was estimated using 1- and 2-tissue-compartment models (1T and 2T, respectively). The distribution volume ratio (DVR) was calculated from V T of target and reference region and obtained with a noninvasive Logan graphical reference tissue method ( t * = 30 min). The applicability of a shortened protocol as an alternative to the 90-min PET scan was investigated. Tracer biodistribution and dosimetry were determined in 3 healthy male subjects, using serial whole-body PET scans acquired over 2 h after 11 C-preladenant injection. Results: There were no serious adverse events in any of the subjects throughout the study period. 11 C-preladenat readily entered the brain, with a peak uptake in the putamen and head of the caudate nucleus 30-40 min after tracer injection. Other brain regions showed rapid clearance of radioactivity. The regional distribution of 11 C-preladenant was consistent with known A 2A R densities in the brain. At pseudoequilibrium (reached at 40 min after injection), stable target-to-cerebellar cortex ratios of around 3.8-10.0 were obtained. The 2T fit better than the 1T in the low-density A 2A R regions. In contrast, there were no significant differences between 1T and 2T in the high-A 2A R-density regions. DVRs in the putamen and head of the caudate nucleus were around 3.8-10.3 when estimated using a Logan graphical reference tissue method with cerebellum as the reference region. PET scanning at 50 or 70 min can provide the stable DVR estimates within 10% or 5% differences at most, respectively. The radioactivity was mainly excreted through the hepatobiliary system after 11 C-preladenant injection. As a result, the absorbed dose (μGy/MBq) was highest in the gallbladder wall (mean ± SD, 17.0 ± 2.5) and liver (11.7 ± 2.1). The estimated effective dose for 11 C-preladenant was 3.7 ± 0.4 μSv/MBq. Conclusion: This initial evaluation indicated that 11 C-preladenat is suitable for imaging of A 2A Rs in the brain. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  3. Genetic diversity and genome-wide association analysis of cooking time in dry bean (Phaseolus vulgaris L.).

    PubMed

    Cichy, Karen A; Wiesinger, Jason A; Mendoza, Fernando A

    2015-08-01

    Fivefold diversity for cooking time found in a panel of 206 Phaseolus vulgaris accessions. Fastest accession cooks nearly 20 min faster than average.   SNPs associated with cooking time on Pv02, 03, and 06. Dry beans (Phaseolus vulgaris L.) are a nutrient dense food and a dietary staple in parts of Africa and Latin America. One of the major factors that limits greater utilization of beans is their long cooking times compared to other foods. Cooking time is an important trait with implications for gender equity, nutritional value of diets, and energy utilization. Very little is known about the genetic diversity and genomic regions involved in determining cooking time. The objective of this research was to assess cooking time on a panel of 206 P. vulgaris accessions, use genome- wide association analysis (GWAS) to identify genomic regions influencing this trait, and to test the ability to predict cooking time by raw seed characteristics. In this study 5.5-fold variation for cooking time was found and five bean accessions were identified which cook in less than 27 min across 2 years, where the average cooking time was 37 min. One accession, ADP0367 cooked nearly 20 min faster than average. Four of these five accessions showed close phylogenetic relationship based on a NJ tree developed with ~5000 SNP markers, suggesting a potentially similar underlying genetic mechanism. GWAS revealed regions on chromosomes Pv02, Pv03, and Pv06 associated with cooking time. Vis/NIR scanning of raw seed explained 68 % of the phenotypic variation for cooking time, suggesting with additional experimentation, it may be possible to use this spectroscopy method to non-destructively identify fast cooking lines as part of a breeding program.

  4. Thermal and structural behavior of anhydrous milk fat. 3. Influence of cooling rate.

    PubMed

    Lopez, C; Lesieur, P; Bourgaux, C; Ollivon, M

    2005-02-01

    The crystallization behavior of anhydrous milk fat has been examined with a new instrument coupling time-resolved synchrotron x-ray diffraction as a function of temperature (XRDT) at both small and wide angles and high-sensitivity differential scanning calorimetry. Crystallizations were monitored at cooling rates of 3 and 1 degrees C/ min from 60 to -10 degrees C to determine the triacylglycerol organizations formed. Simultaneous thermal analysis permitted the correlation of the formation/melting of the different crystalline species monitored by XRDT to the thermal events recorded by differential scanning calorimetry. At intermediate cooling rates, milk fat triacylglycerols sequentially crystallize in 3 different lamellar structures with double-chain length of 46 and 38.5 A and a triple-chain length of 72 A stackings of alpha type, which are correlated to 2 exothermic peaks at 17.2 and 13.7 degrees C, respectively. A time-dependent slow sub-alpha <--> alpha reversible transition is observed at -10 degrees C. Subsequent heating at 2 degrees C/min has shown numerous structural rearrangements of the alpha varieties into a single beta' form before final melting. This polymorphic evolution on heating, as well as the final melting point observed (approximately 39 degrees C), confirmed that cooling at 3 degrees C/min leads to the formation of crystalline varieties that are not at equilibrium. An overall comparison of the thermal and structural properties of the crystalline species formed as a function of the cooling rate and stabilization time is presented. The influence on crystal size of the cooling rates applied in situ using temperature-controlled polarized microscopy is also determined for comparison.

  5. Determinants of [13N]ammonia kinetics in hepatic PET experiments: a minimal recirculatory model.

    PubMed

    Weiss, Michael; Roelsgaard, Klaus; Bender, Dirk; Keiding, Susanne

    2002-12-01

    The aim of this study was the development of a modelling approach for the analysis of the systemic kinetics of the tracer nitrogen-13 ammonia administered for dynamic liver scanning. The radioactive half-life of this tracer is 9.8 min, which limits the time span in which data are available in a positron emission tomography experimental setting. A circulatory pharmacokinetic model was applied to the metabolism of ammonia in anaesthetised pigs, which incorporated data from serial measurements of [(13)N]ammonia and [(13)N]metabolite activity in arterial and portal venous blood together with blood flow rates through the portal vein and through the hepatic artery obtained over 20 min after intravenous injection of [(13)N]ammonia. Model analysis showed that up to 20 min after injection the time course of [(13)N]ammonia concentration in arterial blood is primarily determined by distribution kinetics (steady-state volume of distribution 1,856+/-531 ml kg(-1)). Simultaneous fitting of arterial ammonia and metabolite blood concentrations allowed for estimation of the hepatic [(13)N]ammonia clearance (10.25+/-1.84 ml min(-1) kg(-1)), which accounted for the formation of the circulating metabolites.

  6. Semi-automatic assessment of pediatric hydronephrosis severity in 3D ultrasound

    NASA Astrophysics Data System (ADS)

    Cerrolaza, Juan J.; Otero, Hansel; Yao, Peter; Biggs, Elijah; Mansoor, Awais; Ardon, Roberto; Jago, James; Peters, Craig A.; Linguraru, Marius George

    2016-03-01

    Hydronephrosis is the most common abnormal finding in pediatric urology. Thanks to its non-ionizing nature, ultrasound (US) imaging is the preferred diagnostic modality for the evaluation of the kidney and the urinary track. However, due to the lack of correlation of US with renal function, further invasive and/or ionizing studies might be required (e.g., diuretic renograms). This paper presents a computer-aided diagnosis (CAD) tool for the accurate and objective assessment of pediatric hydronephrosis based on morphological analysis of kidney from 3DUS scans. The integration of specific segmentation tools in the system, allows to delineate the relevant renal structures from 3DUS scans of the patients with minimal user interaction, and the automatic computation of 90 anatomical features. Using the washout half time (T1/2) as indicative of renal obstruction, an optimal subset of predictive features is selected to differentiate, with maximum sensitivity, those severe cases where further attention is required (e.g., in the form of diuretic renograms), from the noncritical ones. The performance of this new 3DUS-based CAD system is studied for two clinically relevant T1/2 thresholds, 20 and 30 min. Using a dataset of 20 hydronephrotic cases, pilot experiments show how the system outperforms previous 2D implementations by successfully identifying all the critical cases (100% of sensitivity), and detecting up to 100% (T1/2 = 20 min) and 67% (T1/2 = 30 min) of non-critical ones for T1/2 thresholds of 20 and 30 min, respectively.

  7. Process improvement to enhance existing stroke team activity toward more timely thrombolytic treatment.

    PubMed

    Cho, Han-Jin; Lee, Kyung Yul; Nam, Hyo Suk; Kim, Young Dae; Song, Tae-Jin; Jung, Yo Han; Choi, Hye-Yeon; Heo, Ji Hoe

    2014-10-01

    Process improvement (PI) is an approach for enhancing the existing quality improvement process by making changes while keeping the existing process. We have shown that implementation of a stroke code program using a computerized physician order entry system is effective in reducing the in-hospital time delay to thrombolysis in acute stroke patients. We investigated whether implementation of this PI could further reduce the time delays by continuous improvement of the existing process. After determining a key indicator [time interval from emergency department (ED) arrival to intravenous (IV) thrombolysis] and conducting data analysis, the target time from ED arrival to IV thrombolysis in acute stroke patients was set at 40 min. The key indicator was monitored continuously at a weekly stroke conference. The possible reasons for the delay were determined in cases for which IV thrombolysis was not administered within the target time and, where possible, the problems were corrected. The time intervals from ED arrival to the various evaluation steps and treatment before and after implementation of the PI were compared. The median time interval from ED arrival to IV thrombolysis in acute stroke patients was significantly reduced after implementation of the PI (from 63.5 to 45 min, p=0.001). The variation in the time interval was also reduced. A reduction in the evaluation time intervals was achieved after the PI [from 23 to 17 min for computed tomography scanning (p=0.003) and from 35 to 29 min for complete blood counts (p=0.006)]. PI is effective for continuous improvement of the existing process by reducing the time delays between ED arrival and IV thrombolysis in acute stroke patients.

  8. Imaging human intrasynaptic dopamine release by IV cocaine and amphetamine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wong, D.F.; Hong, C.; Yokoi, F.

    1995-05-01

    Intrasynaptic dopamine (DA) release was measured with C-11 Raclopride (RAC) PET in 15 human subjects with two psychostimulant drugs, IV cocaine or IV amphetamine (AMPH). Eleven cocaine users received IV saline then cocaine with high specific activity (SA) tracer RAC by IV bolus. To determine the optimal timing of drug administration, subjects received 48mg cocaine at 0 min.(1 subject), 4 min.(3 subjects) or 10 min.(7 subjects) post injection (mpi). One received 32mg at 4 and 16mg at 10 mpi. In a separate paradigm, the effect of AMPH not only on the binding of Hi SA but also on the receptormore » density (B{sub max}) using Hi SA and low SA was examined. Four normals received 2 pairs of Hi SA and Low SA RAC PET scans, each pair separated by 1 week to estimate 2 B{sub max}`s, one affected by AMPH. Before the 2nd pair, 0.3mg/kg IV AMPH was given in the times corresponding to the AMPH times for the 1s B{sub max} measurement. All were scanned on a GE 4096WB+PET with 50 frames over 90 min with radial arterial plasma sampling and HPLC metabolite correction. Neuropsychological-endocrine testing was done concurrently. All subjects had a marked psychophysiological response for cocaine or AMPH (less with Low SA RAC). However, evidence of substantial DA release was not consistent with IV cocaine nor correlated with any timing of cocaine vs. RAC, except for an overall trend for RAC reduction with cocaine. The % change in k{sub 3}/k{sub 4} by graphical analysis ranged from +10 to -21%, with similar changes by other methods of quantification, such as k{sub 3}/k{sub 4} constrained to cerebellar K{sub 1}/k{sub 2}, and simple tissue ratios comparisons. IV AMPH showed DA release (19% {plus_minus} 2 (SEM) decrease) in all Hi SA RAC (k{sub 3}/k{sub 4}) by graphical analysis. The calculation of B{sub max} in putamen using Scatchard analysis (baseline B{sub max}29{plus_minus}2) showed 12 to 28% decreases following AMPH.« less

  9. Assessing exercise cardiac reserve using real-time cardiovascular magnetic resonance.

    PubMed

    Le, Thu-Thao; Bryant, Jennifer Ann; Ting, Alicia Er; Ho, Pei Yi; Su, Boyang; Teo, Raymond Choon Chye; Gan, Julian Siong-Jin; Chung, Yiu-Cho; O'Regan, Declan P; Cook, Stuart A; Chin, Calvin Woon-Loong

    2017-01-23

    Exercise cardiovascular magnetic resonance (ExCMR) has great potential for clinical use but its development has been limited by a lack of compatible equipment and robust real-time imaging techniques. We developed an exCMR protocol using an in-scanner cycle ergometer and assessed its performance in differentiating athletes from non-athletes. Free-breathing real-time CMR (1.5T Aera, Siemens) was performed in 11 athletes (5 males; median age 29 [IQR: 28-39] years) and 16 age- and sex-matched healthy volunteers (7 males; median age 26 [interquartile range (IQR): 25-33] years). All participants underwent an in-scanner exercise protocol on a CMR compatible cycle ergometer (Lode BV, the Netherlands), with an initial workload of 25W followed by 25W-increment every minute. In 20 individuals, exercise capacity was also evaluated by cardiopulmonary exercise test (CPET). Scan-rescan reproducibility was assessed in 10 individuals, at least 7 days apart. The exCMR protocol demonstrated excellent scan-rescan (cardiac index (CI): 0.2 ± 0.5L/min/m 2 ) and inter-observer (ventricular volumes: 1.2 ± 5.3mL) reproducibility. CI derived from exCMR and CPET had excellent correlation (r = 0.83, p < 0.001) and agreement (1.7 ± 1.8L/min/m 2 ). Despite similar values at rest (P = 0.87), athletes had increased exercise CI compared to healthy individuals (at peak exercise: 12.2 [IQR: 10.2-13.5] L/min/m 2 versus 8.9 [IQR: 7.5-10.1] L/min/m 2 , respectively; P < 0.001). Peak exercise CI, where image acquisition lasted 13-17 s, outperformed that at rest (c-statistics = 0.95 [95% confidence interval: 0.87-1.00] versus 0.48 [95% confidence interval: 0.23-0.72], respectively; P < 0.0001 for comparison) in differentiating athletes from healthy volunteers; and had similar performance as VO 2max (c-statistics = 0.84 [95% confidence interval = 0.62-1.00]; P = 0.29 for comparison). We have developed a novel in-scanner exCMR protocol using real-time CMR that is highly reproducible. It may now be developed for clinical use for physiological studies of the heart and circulation.

  10. Morphological bactericidal fast-acting effects of peracetic acid, a high-level disinfectant, against Staphylococcus aureus and Pseudomonas aeruginosa biofilms in tubing.

    PubMed

    Chino, T; Nukui, Y; Morishita, Y; Moriya, K

    2017-01-01

    The bactericidal effect of disinfectants against biofilms is essential to reduce potential endoscopy-related infections caused by contamination. Here, we investigated the bactericidal effect of a high-level disinfectant, peracetic acid (PAA), against Staphylococcus aureus and Pseudomonas aeruginosa biofilm models in vitro. S. aureus and P. aeruginosa biofilms were cultured at 35 °C for 7 days with catheter tubes. The following high-level disinfectants (HLDs) were tested: 0.3% PAA, 0.55% ortho-phthalaldehyde (OPA), and 2.0% alkaline-buffered glutaraldehyde (GA). Biofilms were exposed to these agents for 1-60 min and observed after 5 min and 30 min by transmission and scanning electron microscopy. A Student's t test was performed to compare the exposure time required for bactericidal effectiveness of the disinfectants. PAA and GA were active within 1 min and 5 min, respectively, against S. aureus and P. aeruginosa biofilms. OPA took longer than 10 min and 30 min to act against S. aureus and P. aeruginosa biofilms, respectively ( p  < 0.01). Treatment with PAA elicited changes in cell shape after 5 min and structural damage after 30 min. Amongst the HLDs investigated, PAA elicited the most rapid bactericidal effects against both biofilms. Additionally, treatment with PAA induced morphological alterations in the in vitro biofilm models, suggesting that PAA exerts fast-acting bactericidal effects against biofilms associated with endoscopy-related infections. These findings indicate that the exposure time for bactericidal effectiveness of HLDs for endoscope reprocessing in healthcare settings should be reconsidered.

  11. T2 shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging.

    PubMed

    Tamir, Jonathan I; Uecker, Martin; Chen, Weitian; Lai, Peng; Alley, Marcus T; Vasanawala, Shreyas S; Lustig, Michael

    2017-01-01

    A new acquisition and reconstruction method called T 2 Shuffling is presented for volumetric fast spin-echo (three-dimensional [3D] FSE) imaging. T 2 Shuffling reduces blurring and recovers many images at multiple T 2 contrasts from a single acquisition at clinically feasible scan times (6-7 min). The parallel imaging forward model is modified to account for temporal signal relaxation during the echo train. Scan efficiency is improved by acquiring data during the transient signal decay and by increasing echo train lengths without loss in signal-to-noise ratio (SNR). By (1) randomly shuffling the phase encode view ordering, (2) constraining the temporal signal evolution to a low-dimensional subspace, and (3) promoting spatio-temporal correlations through locally low rank regularization, a time series of virtual echo time images is recovered from a single scan. A convex formulation is presented that is robust to partial voluming and radiofrequency field inhomogeneity. Retrospective undersampling and in vivo scans confirm the increase in sharpness afforded by T 2 Shuffling. Multiple image contrasts are recovered and used to highlight pathology in pediatric patients. A proof-of-principle method is integrated into a clinical musculoskeletal imaging workflow. The proposed T 2 Shuffling method improves the diagnostic utility of 3D FSE by reducing blurring and producing multiple image contrasts from a single scan. Magn Reson Med 77:180-195, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. Evaluation of normal appearing spinal cord by diffusion tensor imaging, fiber tracking, fractional anisotropy, and apparent diffusion coefficient measurement in 13 dogs

    PubMed Central

    2013-01-01

    Background Functional magnetic resonance (fMR) imaging offers plenty of new opportunities in the diagnosis of central nervous system diseases. Diffusion tensor imaging (DTI) is a technique sensitive to the random motion of water providing information about tissue architecture. We applied DTI to normal appearing spinal cords of 13 dogs of different breeds and body weights in a 3.0 T magnetic resonance (MR) scanner. The aim was to study fiber tracking (FT) patterns by tractography and the variations of the fractional anisotropy (FA) and the apparent diffusion coefficient (ADC) observed in the spinal cords of dogs with different sizes and at different locations (cervical and thoracolumbar). For that reason we added a DTI sequence to the standard clinical MR protocol. The values of FA and ADC were calculated by means of three regions of interest defined on the cervical or the thoracolumbar spinal cord (ROI 1, 2, and 3). Results The shape of the spinal cord fiber tracts was well illustrated following tractography and the exiting nerve roots could be differentiated from the spinal cord fiber tracts. Routine MR scanning times were extended for 8 to 12 min, depending on the size of the field of view (FOV), the slice thickness, and the size of the interslice gaps. In small breed dogs (< 15 kg body weight) the fibers could be tracked over a length of approximately 10 vertebral bodies with scanning times of about 8 min, whereas in large breed dogs (> 25 kg body weight) the traceable fiber length was about 5 vertebral bodies which took 10 to 12 min scanning time. FA and ADC values showed mean values of 0.447 (FA), and 0.560 × 10-3 mm2/s (ADC), respectively without any differences detected with regard to different dog sizes and spinal cord 45 segments examined. Conclusion FT is suitable for the graphical depiction of the canine spinal cord and the exiting nerve roots. The FA and ADC values offer an objective measure for evaluation of the spinal cord fiber integrity in dogs. PMID:23618404

  13. Effect of CdS Growth Time on the Optical Properties of One-Pot Preparation of CdS-Ag2S Binary Compounds

    NASA Astrophysics Data System (ADS)

    Karimipour, M.; Izadian, L.; Molaei, M.

    2018-02-01

    CdS-Ag2S binary nanoparticles were synthesized using a facile one-pot microwave irradiation method. The effect of initial nucleation of CdS quantum dots (QDs) using 3 min, 5 min, and 7 min of microwave irradiation on the optical properties of the final compound was studied. The composition and crystal structure of the compounds were verified using energy dispersive x-ray spectroscopy and x-ray diffraction. They revealed that existence of Ag and Cd elements with an atomic ratio of 0.19 crystalizes in the form of monoclinic Ag2S and hexagonal CdS. Scanning electron microscope images showed a spherical morphology of the resultant compound, and transmission electron microscope images showed the formation of fine particles of CdS-Ag2S composites with an average size of 5-7 nm and 10-14 nm for CdS and Ag2S, respectively. Photoluminescence spectroscopy revealed that the initial growth time of CdS has a crucial effect on the emission of binary compounds such that for 3 min and 5 min of irradiation of CdS solution, the binary compound obtains strong red and considerable near-IR emission (850 nm), but for longer time, it rapidly quenches. The results indicate that the strong red emission can be tuned from 600 nm up to 700 nm with prolonging nucleation time of CdS. This study also emphasized that the origin of red emission strongly depends on the size and defects created in the CdS QDs.

  14. Standardized added metabolic activity (SAM): a partial volume independent marker of total lesion glycolysis in liver metastases.

    PubMed

    Mertens, Jeroen; Dobbeleir, André; Ham, Hamphrey; D'Asseler, Yves; Goethals, Ingeborg; Van de Wiele, Christophe

    2012-09-01

    The standardized added metabolic activity (SAM) is a new marker of total lesion glycolysis that avoids partial volume effect (PVE) and thresholding. SAM is calculated by drawing a volume of interest (VOI(1)) around the tumour and a larger VOI (VOI(2)) around VOI(1). Subtracting the background activity in VOI(2)-VOI(1) from VOI(1) yields SAM. If VOI(1) is set at a reasonable distance from the tumour, PVE are avoided. Phantom and initial clinical validation data are presented. Spheres of a Jaszczak phantom were filled with a 5.4, 3.64 and 2.0 times higher concentration relative to background activity and positron emission tomography (PET) data were acquired during 10 min. SAM of all spheres was expressed as a percentage of the expected value (the actual activity ratio minus 1). In 15 patients a 10-min list-mode acquisition PET study centred on their primary squamous cell carcinoma (PSCC) was performed and images of 1-10 min reconstructed. SAM1-9min values of PSCC were expressed as a percentage of SAM10min. Nineteen patients suffering from liver metastases treated with chemotherapy underwent PET/CT prior to (scan 1) and after 3-6 cycles of chemotherapy (scan 2). SAM and maximum standardized uptake values (SUV(max)) of the liver lesions on scan 1 (SAM1 and SUV(max)1) and the percentage reduction between both ΔSAM and ΔSUV(max) were related to Response Evaluation Criteria in Solid Tumors (RECIST) response. For the phantom acquisitions, the mean normalized SAM/sphere volume calculated was 94.9 % (SD 5.9 %) of the expected value. In the PSCC patients, the mean difference between SAM1min and SAM10min was only 4 % (SD 5 %). SUV(max)1min and SUV(max)10min proved to be not significantly different, but the variability was slightly larger than that of SAM (SD 6.4 %). SAM1 and ΔSAM values for responders versus non-responders were, respectively, 57 (SD 119) versus 297 (SD 625) for SAM1 (p = 0.2) and 99 % (SD 3 %) versus 32 % (SD 44 %) for ΔSAM (p = 0.001). SUV(max)1 and ΔSUV(max) values in responders versus non-responders were, respectively, 3.9 (SD 2.4) versus 6.3 (SD 3.1) for SUV(max)1 (p = 0.08) and 94 % (SD 17) versus 7 % (SD 40 %) for ΔSUV(max) (p = 0.0001). The AUC of ΔSAM and ΔSUV(max) were not significantly different on receiver-operating characteristic (ROC) analysis (AUC 1.0 and 0.99, respectively, p = 0.6). SAM is a promising parameter for tumour response assessment of liver metastases by means of (18)F-fluorodeoxyglucose PET.

  15. Potential effects of tooth-brushing on human dentin wear following exposure to acidic soft drinks.

    PubMed

    Choi, S; Park, K-H; Cheong, Y; Moon, S W; Park, Y-G; Park, H-K

    2012-08-01

    This study used scanning electron microscopy and atomic force microscopy to examine the short-term potential effects of brushing time and the start-time of tooth-brushing after demineralization on primary dentin wear in vitro. Thirty-six noncarious primary central incisors were assigned to 12 experimental groups. Exposure to cola drinks was used to initiate the demineralization process. Three brushing times (5, 15 and 30 s) and four start-times of brushing (0, 30, 60 and 120 min) after an erosive attack were used for the abrasion process. Tooth-brushing the softened dentin surface led to increases in the open tubular fraction and microstructural changes on the dentin surface. Brushing immediately after exposure to cola resulted in the greatest irreversible dentin loss, whereas brushing 60 or 120 min after pretreatment resulted in the least irreversible dentin loss. However, brushing time had no effect on the irreversible loss of dentin wear. Based on these experimental results, tooth-brushing should be performed at least 60 min after consuming a cola drink to achieve the desired tooth cleaning and avoid the introduction of surface lesions on dentin. © 2012 The Authors Journal of Microscopy © 2012 Wadsworth Center, New York State Department of Health.

  16. Surface plasmon resonance and nonlinear optical behavior of pulsed laser-deposited semitransparent nanostructured copper thin films

    NASA Astrophysics Data System (ADS)

    Kesarwani, Rahul; Khare, Alika

    2018-06-01

    In this paper, surface plasmon resonance (SPR) and nonlinear optical properties of semitransparent nanostructured copper thin films fabricated on the glass substrate at 400 °C by pulsed laser deposition technique are reported. The thickness, linear absorption coefficient and linear refractive index of the films were measured by spectroscopic ellipsometer. The average particle size as measured via atomic force microscope was in the range of 12.84-26.02 nm for the deposition time ranging from 5 to 10 min, respectively. X-ray diffraction spectra revealed the formation of Cu (111) and Cu (200) planes. All these thin films exhibited broad SPR peak. The third-order optical nonlinearity of all the samples was investigated via modified z-scan technique using cw laser at a wavelength of 632.8 nm. The open aperture z-scan spectra of Cu thin film deposited for 5 min duration exhibited reverse saturation absorption whereas all the other samples displayed saturation absorption behavior. The nonlinear refractive index coefficient of these films showed a positive sign having the magnitude of the order of 10- 4 cm/W. The real and imaginary parts of susceptibilities were also calculated from the z-scan data and found to be of the order of 10- 6 esu.

  17. The measurements of water flow rates in the straight microchannel based on the scanning micro-PIV technique

    NASA Astrophysics Data System (ADS)

    Wang, H. L.; Han, W.; Xu, M.

    2011-12-01

    Measurement of the water flow rate in microchannel has been one of the hottest points in the applications of microfluidics, medical, biological, chemical analyses and so on. In this study, the scanning microscale particle image velocimetry (scanning micro-PIV) technique is used for the measurements of water flow rates in a straight microchannel of 200μm width and 60μm depth under the standard flow rates ranging from 2.481μL/min to 8.269μL/min. The main effort of this measurement technique is to obtain three-dimensional velocity distribution on the cross sections of microchannel by measuring velocities of the different fluid layers along the out-of-plane direction in the microchannel, so the water flow rates can be evaluated from the discrete surface integral of velocities on the cross section. At the same time, the three-dimensional velocity fields in the measured microchannel are simulated numerically using the FLUENT software in order to verify the velocity accuracy of measurement results. The results show that the experimental values of flow rates are well consistent to the standard flow rates input by the syringe pump and the compared results between numerical simulation and experiment are consistent fundamentally. This study indicates that the micro-flow rate evaluated from three-dimensional velocity by the scanning micro-PIV technique is a promising method for the micro-flow rate research.

  18. A study of thermal properties of sodium titanate nanotubes synthesized by microwave-assisted hydrothermal method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Preda, Silviu, E-mail: predas01@yahoo.co.uk; Rutar, Melita; Jožef Stefan International Postgraduate School, Jamova cesta 39, SI-1000 Ljubljana

    2015-11-15

    Highlights: • The microwave-assisted hydrothermal route was used for titanate nanotubes synthesis. • Conversion to single-phase nanotube morphology completes after 8 h reaction time. • The nanotube morphology is stable up to 600 °C, as determined by in-situ XRD and SEM. • Sodium ions migrate to the surface due to thermal motion and structure condensation. - Abstract: Sodium titanate nanotubes (NaTiNTs) were synthesized by microwave-assisted hydrothermal treatment of commercial TiO{sub 2}, at constant temperature (135 °C) and different irradiation times (15 min, 1, 4, 8 and 16 h). The products were characterized by X-ray diffraction, scanning electron microscopy, transmission electronmore » microscopy, differential scanning calorimetry and specific surface area measurements. The irradiation time turned out to be the key parameter for morphological control of the material. Nanotubes were observed already after 15 min of microwave irradiation. The analyses of the products irradiated for 8 and 16 h confirm the complete transformation of the starting TiO{sub 2} powder to NaTiNTs. The nanotubes are open ended with multi-wall structures, with the average outer diameter of 8 nm and specific surface area up to 210 m{sup 2}/g. The morphology, surface area and crystal structure of the sodium titanate nanotubes synthesized by microwave-assisted hydrothermal method were similar to those obtained by conventional hydrothermal method.« less

  19. Time-Optimized High-Resolution Readout-Segmented Diffusion Tensor Imaging

    PubMed Central

    Reishofer, Gernot; Koschutnig, Karl; Langkammer, Christian; Porter, David; Jehna, Margit; Enzinger, Christian; Keeling, Stephen; Ebner, Franz

    2013-01-01

    Readout-segmented echo planar imaging with 2D navigator-based reacquisition is an uprising technique enabling the sampling of high-resolution diffusion images with reduced susceptibility artifacts. However, low signal from the small voxels and long scan times hamper the clinical applicability. Therefore, we introduce a regularization algorithm based on total variation that is applied directly on the entire diffusion tensor. The spatially varying regularization parameter is determined automatically dependent on spatial variations in signal-to-noise ratio thus, avoiding over- or under-regularization. Information about the noise distribution in the diffusion tensor is extracted from the diffusion weighted images by means of complex independent component analysis. Moreover, the combination of those features enables processing of the diffusion data absolutely user independent. Tractography from in vivo data and from a software phantom demonstrate the advantage of the spatially varying regularization compared to un-regularized data with respect to parameters relevant for fiber-tracking such as Mean Fiber Length, Track Count, Volume and Voxel Count. Specifically, for in vivo data findings suggest that tractography results from the regularized diffusion tensor based on one measurement (16 min) generates results comparable to the un-regularized data with three averages (48 min). This significant reduction in scan time renders high resolution (1×1×2.5 mm3) diffusion tensor imaging of the entire brain applicable in a clinical context. PMID:24019951

  20. Tracer Kinetic Analysis of (S)-¹⁸F-THK5117 as a PET Tracer for Assessing Tau Pathology.

    PubMed

    Jonasson, My; Wall, Anders; Chiotis, Konstantinos; Saint-Aubert, Laure; Wilking, Helena; Sprycha, Margareta; Borg, Beatrice; Thibblin, Alf; Eriksson, Jonas; Sörensen, Jens; Antoni, Gunnar; Nordberg, Agneta; Lubberink, Mark

    2016-04-01

    Because a correlation between tau pathology and the clinical symptoms of Alzheimer disease (AD) has been hypothesized, there is increasing interest in developing PET tracers that bind specifically to tau protein. The aim of this study was to evaluate tracer kinetic models for quantitative analysis and generation of parametric images for the novel tau ligand (S)-(18)F-THK5117. Nine subjects (5 with AD, 4 with mild cognitive impairment) received a 90-min dynamic (S)-(18)F-THK5117 PET scan. Arterial blood was sampled for measurement of blood radioactivity and metabolite analysis. Volume-of-interest (VOI)-based analysis was performed using plasma-input models; single-tissue and 2-tissue (2TCM) compartment models and plasma-input Logan and reference tissue models; and simplified reference tissue model (SRTM), reference Logan, and SUV ratio (SUVr). Cerebellum gray matter was used as the reference region. Voxel-level analysis was performed using basis function implementations of SRTM, reference Logan, and SUVr. Regionally averaged voxel values were compared with VOI-based values from the optimal reference tissue model, and simulations were made to assess accuracy and precision. In addition to 90 min, initial 40- and 60-min data were analyzed. Plasma-input Logan distribution volume ratio (DVR)-1 values agreed well with 2TCM DVR-1 values (R(2)= 0.99, slope = 0.96). SRTM binding potential (BP(ND)) and reference Logan DVR-1 values were highly correlated with plasma-input Logan DVR-1 (R(2)= 1.00, slope ≈ 1.00) whereas SUVr(70-90)-1 values correlated less well and overestimated binding. Agreement between parametric methods and SRTM was best for reference Logan (R(2)= 0.99, slope = 1.03). SUVr(70-90)-1 values were almost 3 times higher than BP(ND) values in white matter and 1.5 times higher in gray matter. Simulations showed poorer accuracy and precision for SUVr(70-90)-1 values than for the other reference methods. SRTM BP(ND) and reference Logan DVR-1 values were not affected by a shorter scan duration of 60 min. SRTM BP(ND) and reference Logan DVR-1 values were highly correlated with plasma-input Logan DVR-1 values. VOI-based data analyses indicated robust results for scan durations of 60 min. Reference Logan generated quantitative (S)-(18)F-THK5117 DVR-1 parametric images with the greatest accuracy and precision and with a much lower white-matter signal than seen with SUVr(70-90)-1 images. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  1. Imaging of cerebral α4β2* nicotinic acetylcholine receptors with (−)-[18F]Flubatine PET: Implementation of bolus plus constant infusion and sensitivity to acetylcholine in human brain☆

    PubMed Central

    Hillmer, A.T.; Esterlis, I.; Gallezot, J.D.; Bois, F.; Zheng, M.Q.; Nabulsi, N.; Lin, S.F.; Papke, R.L.; Huang, Y.; Sabri, O.; Carson, R.E.; Cosgrove, K.P.

    2016-01-01

    The positron emission tomography (PET) radioligand (−)-[18F]flubatine is specific to α4β2∗ nicotinic acetylcholine receptors (nAChRs) and has promise for future investigation of the acetylcholine system in neuropathologies such as Alzheimer's disease, schizophrenia, and substance use disorders. The two goals of this work were to develop a simplified method for α4β2∗ nAChR quantification with bolus plus constant infusion (B/I) (−)-[18F]flubatine administration, and to assess the radioligand's sensitivity to acetylcholine fluctuations in humans. Healthy human subjects were imaged following either bolus injection (n = 8) or B/I (n = 4) administration of (−)-[18F]flubatine. The metabolite-corrected input function in arterial blood was measured. Free-fraction corrected distribution volumes (VT/fP) were estimated with modeling and graphical analysis techniques. Next, sensitivity to acetylcholine was assessed in two ways: 1. A bolus injection paradigm with two scans (n = 6), baseline (scan 1) and physostigmine challenge (scan 2; 1.5 mg over 60 min beginning 5 min prior to radiotracer injection); 2. A single scan B/I paradigm (n = 7) lasting up to 240 min with 1.5 mg physostigmine administered over 60 min beginning at 125 min of radiotracer infusion. Changes in VT/fP were measured. Baseline VT/fP values were 33.8 ± 3.3 mL/cm3 in thalamus, 12.9 ± 1.6 mL/cm3 in cerebellum, and ranged from 9.8 to 12.5 mL/cm3 in other gray matter regions. The B/I paradigm with equilibrium analysis at 120 min yielded comparable VT/fP values with compartment modeling analysis of bolus data in extrathalamic gray matter regions (regional means <4% different). Changes in VT/fP following physostigmine administration were small and most pronounced in cortical regions, ranging from 0.8 to 4.6% in the two-scan paradigm and 2.8 to 6.5% with the B/I paradigm. These results demonstrate the use of B/I administration for accurate quantification of (−)-[18F]flubatine VT/fP in 120 min, and suggest possible sensitivity of (−)-[18F]flubatine binding to physostigmine-induced changes in acetylcholine levels. PMID:27426839

  2. Imaging of cerebral α4β2* nicotinic acetylcholine receptors with (-)-[(18)F]Flubatine PET: Implementation of bolus plus constant infusion and sensitivity to acetylcholine in human brain.

    PubMed

    Hillmer, A T; Esterlis, I; Gallezot, J D; Bois, F; Zheng, M Q; Nabulsi, N; Lin, S F; Papke, R L; Huang, Y; Sabri, O; Carson, R E; Cosgrove, K P

    2016-11-01

    The positron emission tomography (PET) radioligand (-)-[(18)F]flubatine is specific to α4β2(⁎) nicotinic acetylcholine receptors (nAChRs) and has promise for future investigation of the acetylcholine system in neuropathologies such as Alzheimer's disease, schizophrenia, and substance use disorders. The two goals of this work were to develop a simplified method for α4β2(⁎) nAChR quantification with bolus plus constant infusion (B/I) (-)-[(18)F]flubatine administration, and to assess the radioligand's sensitivity to acetylcholine fluctuations in humans. Healthy human subjects were imaged following either bolus injection (n=8) or B/I (n=4) administration of (-)-[(18)F]flubatine. The metabolite-corrected input function in arterial blood was measured. Free-fraction corrected distribution volumes (VT/fP) were estimated with modeling and graphical analysis techniques. Next, sensitivity to acetylcholine was assessed in two ways: 1. A bolus injection paradigm with two scans (n=6), baseline (scan 1) and physostigmine challenge (scan 2; 1.5mg over 60min beginning 5min prior to radiotracer injection); 2. A single scan B/I paradigm (n=7) lasting up to 240min with 1.5mg physostigmine administered over 60min beginning at 125min of radiotracer infusion. Changes in VT/fP were measured. Baseline VT/fP values were 33.8±3.3mL/cm(3) in thalamus, 12.9±1.6mL/cm(3) in cerebellum, and ranged from 9.8 to 12.5mL/cm(3) in other gray matter regions. The B/I paradigm with equilibrium analysis at 120min yielded comparable VT/fP values with compartment modeling analysis of bolus data in extrathalamic gray matter regions (regional means <4% different). Changes in VT/fP following physostigmine administration were small and most pronounced in cortical regions, ranging from 0.8 to 4.6% in the two-scan paradigm and 2.8 to 6.5% with the B/I paradigm. These results demonstrate the use of B/I administration for accurate quantification of (-)-[(18)F]flubatine VT/fP in 120min, and suggest possible sensitivity of (-)-[(18)F]flubatine binding to physostigmine-induced changes in acetylcholine levels. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Antimicrobial peptide 99mTc-ubiquicidin 29-41 as human infection-imaging agent: clinical trial.

    PubMed

    Akhtar, Muhammad Saeed; Qaisar, Aitzaz; Irfanullah, Javaid; Iqbal, Javaid; Khan, Bashar; Jehangir, Mustansar; Nadeem, Muhammad Afzal; Khan, Muhammad Aleem; Afzal, Muhammad Shahzad; Ul-Haq, Ikram; Imran, Muhammad Babar

    2005-04-01

    Ubiquicidin (UBI) 29-41 is a cationic, synthetic antimicrobial peptide fragment that binds preferentially with the anionic microbial cell membrane at the site of infection. The current study was conducted to evaluate its potential as an infection-imaging agent in humans. Eighteen patients, 9 female and 9 male (mean age, 31.7 y; range, 5-75 y), with suspected bone, soft-tissue, or prosthesis infections were included in the study. (99m)Tc-UBI 29-41 in a dose of 400 microg/370-400 MBq was injected intravenously in adults. A dynamic study was followed by spot views of the suspected region of infection (target) and a corresponding normal area (nontarget) at 30, 60, 120, and 240 min. The target-to-nontarget ratios were used to find the optimum time for imaging. Whole-body anterior and posterior images were also acquired at 30, 120, and 240 min to study biodistribution. Activity in each organ was expressed as percentage retained dose. Visual score (0-3) was used to categorize studies as positive or negative, with scores of 0 (minimal or no uptake; equivalent to soft tissue) and 1 (mild; less uptake than in liver) being considered negative and scores of 2 (moderate; uptake greater than or equal to that in liver) and 3 (intense; uptake greater than or equal to that in kidneys) being considered positive. Scans were interpreted as true- or false-positive and true- or false-negative on the basis of bacterial culture as the major criterion and the results of clinical tests, radiography, and 3-phase bone scanning as minor criteria. The biodistribution study showed a gradual decline in renal activity as percentage of administered dose from 6.53% +/- 0.58% at 30 min to 4.54% +/- 0.57% at 120 min and 3.38% +/- 0.55% at 240 min. The liver showed a similar trend, with values of 5.43% +/- 0.76%, 3.17% +/- 0.25%, and 2.02% +/- 0.30% at 30, 120, and 240 min, respectively. Radioactivity accumulated gradually in the urinary bladder, with values of 4.60% +/- 0.92% at 30 min, 23.00% +/- 2.32% at 120 min, and 38.85% +/- 4.01% at 240 min. Of 18 studies performed with 99mTc-UBI 29-41, 14 showed positive findings and 4 showed negative findings. Negative findings were subsequently confirmed to be true negative. The positive findings for 1 scan were interpreted as false positive, as no growth was obtained on bacterial culture and no evidence of infection was found on minor criteria. In 10 cases, the major criterion was used, whereas in 4 cases minor criteria had to be used for interpretation. Quantitative analysis revealed a maximum mean target-to-nontarget ratio of 2.75 +/- 1.69 at 30 min, which decreased to 2.04 +/- 1.01 at 120 min. The overall sensitivity, specificity, and accuracy were 100%, 80%, and 94.4%, respectively. No adverse reactions were observed during image acquisition and within 5 d after the study. 99mTc-UBI 29-41 showed promise in localizing foci of infection, with optimal visualization at 30 min.

  4. Multiphase Microstructure in a Metastability-Assisted Medium Carbon Alloy Steel

    NASA Astrophysics Data System (ADS)

    Liu, Cheng; Cui, Xixi; Yang, Chen

    2018-05-01

    A medium carbon alloy steel is processed by austenizing at 900 °C for 30 min, then rapid quenching into a patented quenching liquid and holding at 170 °C for 5 min, finally isothermally holding at 250 °C for different times. The morphology and mechanical properties are performed by using optical microscopy and scanning electron microscopy. A multiphase microstructure characterized by a mixture of lenticular prior martensite (PM), fine needle bainitic ferrite and filmy retained austenite (RA) is obtained. It is found that the PM formed firstly upon quenching can accelerate the subsequent bainitic transformation and promote refinement of multiphase colonies. The results show that an optimum mechanical property of a 4000.9 MPa bending strength and a 2030 MPa tensile strength is achieved at 250 °C for 120 min, which is attributed to the multiphase microstructural characteristics and a high product of the volume fraction of RA and the carbon content of austenite.

  5. A preliminary study on the effects of acute ethanol ingestion on default mode network and temporal fractal properties of the brain.

    PubMed

    Weber, Alexander M; Soreni, Noam; Noseworthy, Michael D

    2014-08-01

    To study the effect of acute alcohol intoxication on the functional connectivity of the default mode network (DMN) and temporal fractal properties of the healthy adult brain. Eleven healthy male volunteers were asked to drink 0.59 g/kg of ethanol. Resting state blood oxygen level dependent (rsBOLD) MRI scans were obtained before consumption, 60 min post-consumption and 90 min post-consumption. Before each rsBOLD scan, pointed-resolved spectroscopy (PRESS) (1)H-MRS (magnetic resonance spectroscopy) scans were acquired to measure ethanol levels in the right basal ganglia. Significant changes in DMN connectivity were found following alcohol consumption (p < 0.01). Both increased and decreased regional connectivity were found after 60 min, whereas mostly decreased connectivity was found after 90 min. The fractal behaviour of the rsBOLD signal, which is believed to help reveal complexity of small-scale neuronal circuitry, became more ordered after both 60 and 90 min of alcohol consumption (p < 0.01). The DMN has been linked to personal identity and social behavior. As such, our preliminary findings may provide insight into the neuro-functional underpinnings of the cognitive and behavioral changes observed during acute alcohol intoxication. The reduced fractal dimension implies a change in function of small-scale neural networks towards less complex signaling.

  6. Structured Light Based 3d Scanning for Specular Surface by the Combination of Gray Code and Phase Shifting

    NASA Astrophysics Data System (ADS)

    Zhang, Yujia; Yilmaz, Alper

    2016-06-01

    Surface reconstruction using coded structured light is considered one of the most reliable techniques for high-quality 3D scanning. With a calibrated projector-camera stereo system, a light pattern is projected onto the scene and imaged by the camera. Correspondences between projected and recovered patterns are computed in the decoding process, which is used to generate 3D point cloud of the surface. However, the indirect illumination effects on the surface, such as subsurface scattering and interreflections, will raise the difficulties in reconstruction. In this paper, we apply maximum min-SW gray code to reduce the indirect illumination effects of the specular surface. We also analysis the errors when comparing the maximum min-SW gray code and the conventional gray code, which justifies that the maximum min-SW gray code has significant superiority to reduce the indirect illumination effects. To achieve sub-pixel accuracy, we project high frequency sinusoidal patterns onto the scene simultaneously. But for specular surface, the high frequency patterns are susceptible to decoding errors. Incorrect decoding of high frequency patterns will result in a loss of depth resolution. Our method to resolve this problem is combining the low frequency maximum min-SW gray code and the high frequency phase shifting code, which achieves dense 3D reconstruction for specular surface. Our contributions include: (i) A complete setup of the structured light based 3D scanning system; (ii) A novel combination technique of the maximum min-SW gray code and phase shifting code. First, phase shifting decoding with sub-pixel accuracy. Then, the maximum min-SW gray code is used to resolve the ambiguity resolution. According to the experimental results and data analysis, our structured light based 3D scanning system enables high quality dense reconstruction of scenes with a small number of images. Qualitative and quantitative comparisons are performed to extract the advantages of our new combined coding method.

  7. Evaluation of the Wind Flow Variability Using Scanning Doppler Lidar Measurements

    NASA Astrophysics Data System (ADS)

    Sand, S. C.; Pichugina, Y. L.; Brewer, A.

    2016-12-01

    Better understanding of the wind flow variability at the heights of the modern turbines is essential to accurately assess of generated wind power and efficient turbine operations. Nowadays the wind energy industry often utilizes scanning Doppler lidar to measure wind-speed profiles at high spatial and temporal resolution.The study presents wind flow features captured by scanning Doppler lidars during the second Wind Forecast and Improvement Project (WFIP 2) sponsored by the Department of Energy (DOE) and National Oceanic and Atmospheric Administration (NOAA). This 18-month long experiment in the Columbia River Basin aims to improve model wind forecasts complicated by mountain terrain, coastal effects, and numerous wind farms.To provide a comprehensive dataset to use for characterizing and predicting meteorological phenomena important to Wind Energy, NOAA deployed scanning, pulsed Doppler lidars to two sites in Oregon, one at Wasco, located upstream of all wind farms relative to the predominant westerly flow in the region, and one at Arlington, located in the middle of several wind farms.In this presentation we will describe lidar scanning patterns capable of providing data in conical, or vertical-slice modes. These individual scans were processed to obtain 15-min averaged profiles of wind speed and direction in real time. Visualization of these profiles as time-height cross sections allows us to analyze variability of these parameters with height, time and location, and reveal periods of rapid changes (ramp events). Examples of wind flow variability between two sites of lidar measurements along with examples of reduced wind velocity downwind of operating turbines (wakes) will be presented.

  8. Quantification of 11C-Laniquidar Kinetics in the Brain.

    PubMed

    Froklage, Femke E; Boellaard, Ronald; Bakker, Esther; Hendrikse, N Harry; Reijneveld, Jaap C; Schuit, Robert C; Windhorst, Albert D; Schober, Patrick; van Berckel, Bart N M; Lammertsma, Adriaan A; Postnov, Andrey

    2015-11-01

    Overexpression of the multidrug efflux transport P-glycoprotein may play an important role in pharmacoresistance. (11)C-laniquidar is a newly developed tracer of P-glycoprotein expression. The aim of this study was to develop a pharmacokinetic model for quantification of (11)C-laniquidar uptake and to assess its test-retest variability. Two (test-retest) dynamic (11)C-laniquidar PET scans were obtained in 8 healthy subjects. Plasma input functions were obtained using online arterial blood sampling with metabolite corrections derived from manual samples. Coregistered T1 MR images were used for region-of-interest definition. Time-activity curves were analyzed using various plasma input compartmental models. (11)C-laniquidar was metabolized rapidly, with a parent plasma fraction of 50% at 10 min after tracer injection. In addition, the first-pass extraction of (11)C-laniquidar was low. (11)C-laniquidar time-activity curves were best fitted to an irreversible single-tissue compartment (1T1K) model using conventional models. Nevertheless, significantly better fits were obtained using 2 parallel single-tissue compartments, one for parent tracer and the other for labeled metabolites (dual-input model). Robust K1 results were also obtained by fitting the first 5 min of PET data to the 1T1K model, at least when 60-min plasma input data were used. For both models, the test-retest variability of (11)C-laniquidar rate constant for transfer from arterial plasma to tissue (K1) was approximately 19%. The accurate quantification of (11)C-laniquidar kinetics in the brain is hampered by its fast metabolism and the likelihood that labeled metabolites enter the brain. Best fits for the entire 60 min of data were obtained using a dual-input model, accounting for uptake of (11)C-laniquidar and its labeled metabolites. Alternatively, K1 could be obtained from a 5-min scan using a standard 1T1K model. In both cases, the test-retest variability of K1 was approximately 19%. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  9. (18)F-alfatide II and (18)F-FDG dual-tracer dynamic PET for parametric, early prediction of tumor response to therapy.

    PubMed

    Guo, Jinxia; Guo, Ning; Lang, Lixin; Kiesewetter, Dale O; Xie, Qingguo; Li, Quanzheng; Eden, Henry S; Niu, Gang; Chen, Xiaoyuan

    2014-01-01

    A single dynamic PET acquisition using multiple tracers administered closely in time could provide valuable complementary information about a tumor's status under quasiconstant conditions. This study aimed to investigate the utility of dual-tracer dynamic PET imaging with (18)F-alfatide II ((18)F-AlF-NOTA-E[PEG4-c(RGDfk)]2) and (18)F-FDG for parametric monitoring of tumor responses to therapy. We administered doxorubicin to one group of athymic nude mice with U87MG tumors and paclitaxel protein-bound particles to another group of mice with MDA-MB-435 tumors. To monitor therapeutic responses, we performed dual-tracer dynamic imaging, in sessions that lasted 90 min, starting with injection via the tail vein catheters with (18)F-alfatide II, followed 40 min later by (18)F-FDG. To achieve signal separation of the 2 tracers, we fit a 3-compartment reversible model to the time-activity curve of (18)F-alfatide II for the 40 min before (18)F-FDG injection and then extrapolated to 90 min. The (18)F-FDG tumor time-activity curve was isolated from the 90-min dual-tracer tumor time-activity curve by subtracting the fitted (18)F-alfatide II tumor time-activity curve. With separated tumor time-activity curves, the (18)F-alfatide II binding potential (Bp = k3/k4) and volume of distribution (VD) and (18)F-FDG influx rate ((K1 × k3)/(k2 + k3)) based on the Patlak method were calculated to validate the signal recovery in a comparison with 60-min single-tracer imaging and to monitor therapeutic response. The transport and binding rate parameters K1-k3 of (18)F-alfatide II, calculated from the first 40 min of the dual-tracer dynamic scan, as well as Bp and VD correlated well with the parameters from the 60-min single-tracer scan (R(2) > 0.95). Compared with the results of single-tracer PET imaging, (18)F-FDG tumor uptake and influx were recovered well from dual-tracer imaging. On doxorubicin treatment, whereas no significant changes in static tracer uptake values of (18)F-alfatide II or (18)F-FDG were observed, both (18)F-alfatide II Bp and (18)F-FDG influx from kinetic analysis in tumors showed significant decreases. For therapy of MDA-MB-435 tumors with paclitaxel protein-bound particles, a significant decrease was observed only with (18)F-alfatide II Bp value from kinetic analysis but not (18)F-FDG influx. The parameters fitted with compartmental modeling from the dual-tracer dynamic imaging are consistent with those from single-tracer imaging, substantiating the feasibility of this methodology. Even though no significant differences in tumor size were found until 5 d after doxorubicin treatment started, at day 3 there were already substantial differences in (18)F-alfatide II Bp and (18)F-FDG influx rate. Dual-tracer imaging can measure (18)F-alfatide II Bp value and (18)F-FDG influx simultaneously to evaluate tumor angiogenesis and metabolism. Such changes are known to precede anatomic changes, and thus parametric imaging may offer the promise of early prediction of therapy response.

  10. Effects of in-office bleaching on human enamel and dentin. Morphological and mineral changes.

    PubMed

    Llena, Carmen; Esteve, Irene; Forner, Leopoldo

    2018-05-01

    The effects of HP-based products upon dental enamel and dentin are inconclusive. To evaluate changes in micromorphology and composition of calcium (Ca) and phosphate (P) in enamel and dentin after the application of 37.5% hydrogen peroxide (HP) and 35% carbamide peroxide (CP) METHODS: Crowns of 20 human teeth were divided in two halves. One half was used as control specimen and the other as experimental specimen. The control specimens were kept in artificial saliva, and the experimental specimens were divided into four groups (n=5 each): group 1 (enamel HP for 45min); group 2 (dentin HP for 45min); group 3 (enamel CP for 90min); and group 4 (dentin CP for 90min). The morphological changes were evaluated using confocal laser scanning microscopy (CLSM), while the changes in the composition of Ca and P were assessed using environmental scanning electron microscopy combined with a microanalysis system (ESEM+EDX). The results within each group and between groups were compared using the Wilcoxon test and Mann-Whitney U-test, respectively (p<0.05). Similar morphological changes in the enamel and no changes in dentin were assessed with both products. Ca and P decreased in enamel and dentin, without significant differences between them or with respect to their control specimens (p>0.05). When bleaching products with a neutral pH are used in clinical practice, both, the concentration and the application time should be taken into account in order to avoid possible structural and mineral changes in enamel and dentin. Copyright © 2018 Elsevier GmbH. All rights reserved.

  11. Patient-specific optimisation of administered activity and acquisition times for 18F-FDG PET imaging.

    PubMed

    Wickham, Fred; McMeekin, Helena; Burniston, Maria; McCool, Daniel; Pencharz, Deborah; Skillen, Annah; Wagner, Thomas

    2017-12-01

    The purpose of this study is to identify a method for optimising the administered activity and acquisition time for 18 F-FDG PET imaging, yielding images of consistent quality for patients with varying body sizes and compositions, while limiting radiation doses to patients and staff. Patients referred for FDG scans had bioimpedance measurements. They were injected with 3 MBq/kg of 18 F up to 370 MBq and scanned on a Siemens Biograph mCT at 3 or 4 min per bed position. Data were rebinned to simulate 2- and 1-min acquisitions. Subjective assessments of image quality made by an experienced physician were compared with objective measurements based on signal-to-noise ratio and noise equivalent counts (NEC). A target objective measure of image quality was identified. The activity and acquisition time required to achieve this were calculated for each subject. Multiple regression analysis was used to identify expressions for the activity and acquisition time required in terms of easily measurable patient characteristics. One hundred and eleven patients were recruited, and subjective and objective assessments of image quality were compared for 321 full and reduced time scans. NEC-per-metre was identified as the objective measure which best correlated with the subjective assessment (Spearman rank correlation coefficient 0.77) and the best discriminator for images with a subjective assessment of "definitely adequate" (area under the ROC curve 0.94). A target of 37 Mcount/m was identified. Expressions were identified in terms of patient sex, height and weight for the activity and acquisition time required to achieve this target. Including measurements of body composition in these expressions was not useful. Using these expressions would reduce the mean activity administered to this patient group by 66 MBq compared to the current protocol. Expressions have been identified for the activity and acquisition times required to achieve consistent image quality in FDG imaging with reduced patient and staff doses. These expressions might need to be adapted for other systems and reconstruction protocols.

  12. Separation of paralytic shellfish poisoning toxins on Chromarods-SIII by thin-layer chromatography with the Iatroscan (mark 5) and flame thermionic detection.

    PubMed

    Indrasena, W M; Ackman, R G; Gill, T A

    1999-09-10

    Thin-layer chromatography (TLC) on Chromarods-SIII with the Iatroscan (Mark-5) and a flame thermionic detector (FTID) was used to develop a rapid method for the detection of paralytic shellfish poisoning (PSP) toxins. The effect of variation in hydrogen (H2) flow, air flow, scan time and detector current on the FTID peak response for both phosphatidylcholine (PC) and PSP were studied in order to define optimum detection conditions. A combination of hydrogen and air flow-rates of 50 ml/min and 1.5-2.0 l/min respectively, along with a scan time of 40 s/rod and detector current of 3.0 A (ampere) or above were found to yield the best results for the detection of PSP compounds. Increasing the detector current level to as high as 3.3 A gave about 130 times more FTID response than did flame ionization detection (FID), for PSP components. Quantities of standards as small as 1 ng neosaxitoxin (NEO), 5 ng saxitoxin (STX), 5 ng B1-toxins (B1), 2 ng gonyautoxin (GTX) 2/3, 6 ng GTX 1/4 and 6 ng C-toxins (C1/C2) could be detected with the FTID. The method detection limits for toxic shellfish tissues using the FTID were 0.4, 2.1, 0.8 and 2.5 micrograms per g tissue for GTX 2/3, STX, NEO and C toxins, respectively. The FTID response increased with increasing detector current and with increasing the scan time. Increasing hydrogen and air flow-rates resulted in decreasing sensitivity within defined limits. Numerous solvent systems were tested, and, solvent consisting of chloroform: methanol-water-acetic acid (30:50:8:2) could separate C toxins from GTX, which eluted ahead of NEO and STX. Accordingly, TLC/FTID with the Iatroscan (Mark-5) seems to be a promising, relatively inexpensive and rapid method of screening plant and animal tissues for PSP toxins.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Regmi, Rajesh; Lovelock, D. Michael; Zhang, Pengpeng

    Purpose: To investigate constancy, within a treatment session, of the time lag relationship between implanted markers in abdominal tumors and an external motion surrogate. Methods: Six gastroesophageal junction and three pancreatic cancer patients (IRB-approved protocol) received two cone-beam CTs (CBCT), one before and one after treatment. Time between scans was less than 30 min. Each patient had at least one implanted fiducial marker near the tumor. In all scans, abdominal displacement (Varian RPM) was recorded as the external motion signal. Purpose-built software tracked fiducials, representing internal signal, in CBCT projection images. Time lag between superior–inferior (SI) internal and anterior–posterior externalmore » signals was found by maximizing the correlation coefficient in each breathing cycle and averaging over all cycles. Time-lag-induced discrepancy between internal SI position and that predicted from the external signal (external prediction error) was also calculated. Results: Mean ± standard deviation time lag, over all scans and patients, was 0.10 ± 0.07 s (range 0.01–0.36 s). External signal lagged the internal in 17/18 scans. Change in time lag between pre- and post-treatment CBCT was 0.06 ± 0.07 s (range 0.01–0.22 s), corresponding to 3.1% ± 3.7% (range 0.6%–10.8%) of gate width (range 1.6–3.1 s). In only one patient, change in time lag exceeded 10% of the gate width. External prediction error over all scans of all patients varied from 0.1 ± 0.1 to 1.6 ± 0.4 mm. Conclusions: Time lag between internal motion along SI and external signals is small compared to the treatment gate width of abdominal patients examined in this study. Change in time lag within a treatment session, inferred from pre- to post-treatment measurements is also small, suggesting that a single measurement of time lag at the session start is adequate. These findings require confirmation in a larger number of patients.« less

  14. Parametric Methods for Dynamic 11C-Phenytoin PET Studies.

    PubMed

    Mansor, Syahir; Yaqub, Maqsood; Boellaard, Ronald; Froklage, Femke E; de Vries, Anke; Bakker, Esther D M; Voskuyl, Rob A; Eriksson, Jonas; Schwarte, Lothar A; Verbeek, Joost; Windhorst, Albert D; Lammertsma, Adriaan A

    2017-03-01

    In this study, the performance of various methods for generating quantitative parametric images of dynamic 11 C-phenytoin PET studies was evaluated. Methods: Double-baseline 60-min dynamic 11 C-phenytoin PET studies, including online arterial sampling, were acquired for 6 healthy subjects. Parametric images were generated using Logan plot analysis, a basis function method, and spectral analysis. Parametric distribution volume (V T ) and influx rate ( K 1 ) were compared with those obtained from nonlinear regression analysis of time-activity curves. In addition, global and regional test-retest (TRT) variability was determined for parametric K 1 and V T values. Results: Biases in V T observed with all parametric methods were less than 5%. For K 1 , spectral analysis showed a negative bias of 16%. The mean TRT variabilities of V T and K 1 were less than 10% for all methods. Shortening the scan duration to 45 min provided similar V T and K 1 with comparable TRT performance compared with 60-min data. Conclusion: Among the various parametric methods tested, the basis function method provided parametric V T and K 1 values with the least bias compared with nonlinear regression data and showed TRT variabilities lower than 5%, also for smaller volume-of-interest sizes (i.e., higher noise levels) and shorter scan duration. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  15. High performance supercapacitor using porous carbon nanomaterial from corn cob

    NASA Astrophysics Data System (ADS)

    Sharma, Nallin; Mishra, Neeraj; Sharon, Madhuri; Sharon, Maheshwar

    2013-06-01

    Carbon synthesized from corn-cob has been used as an electrode in Electrochemical Double Layer Capacitor (EDLC). Dried Corn Cobs, soaked in 1N KOH, 1N HCl or 5% ZnCl2 at 10 0°C for 24 hr, were pyrolyzed in presence of Ar using Co as catalyst at 700-900 °C having dwell time of 60-180 min. The morphology of thus obtained carbon was studied under SEM that showed it to be porous carbon. All the carbon samples synthesized using different parameters were used as electrode for EDLC. Cyclic Voltammetry was used to measure the capacitance. Carbon synthesized from corn cobs pre-treated with 5% ZnCl2 using Co as catalyst pyrolyzed at 700°C for a dwell time of 120 min gave higher Specific capacitance of 270 F/g at scan rate of 5 mV/s. Moreover, this carbon, as observed under SEM, exhibited larger pore size.

  16. Kinetics of imidization and crosslinking in PMR-polyimide resin

    NASA Technical Reports Server (NTRS)

    Lauver, R. W.

    1977-01-01

    Infrared spectroscopy and differential scanning calorimetry were employed to study the imidization and crosslinking kinetics of norbornenyl-capped, addition-type polyimide resins (designated PMR for polymerization of monomer reactants). The spectral and thermal analyses were performed on resin specimens which had been isothermally aged at temperatures appropriate for imidization (120 to 204 C) and crosslinking (275 to 325 C). Imidization occurs rapidly (approximately 0.01/min) at short times, while at times longer than approximately 0.5 hour, the rate decreases significantly (approximately 0.0001/min). The crosslinking reaction exhibits first order kinetics during the initial portion of the reaction and its rate appears to be limited by the reversion of the norbornenyl Diels-Alder adduct. The total heat evolved per mole of endcap during crosslinking shows an inverse dependence on the molecular weight of the imide prepolymers. This reflects the effect of endcap dilution and decreased mobility of the larger oligomers.

  17. Selected Physical Properties of 2-Chloroethyl-3-Chloropropyl Sulfide (CECPRS)

    DTIC Science & Technology

    2010-10-01

    Analysis * For this work, a TA Instruments 910 Differential Scanning Calorimeter and 2200 Controller were used. Prior to sample measurements, the DSC...controlled mass flow rate over a known time, concentrated, and the mass quantified by GC-FID analysis . This step enables vapor pressure measurements for low...Bellefonte, PA), with a 1.0 (im RTx-1 ( polydimethylsiloxane ) stationary phase, was maintained at 40 °C for 2 min following sample introduction, then heated

  18. FDG-PET scan shows increased cerebral blood flow in rat after sublingual glycine application

    NASA Astrophysics Data System (ADS)

    Blagosklonov, Oleg; Podoprigora, Guennady I.; Davani, Siamak; Nartsissov, Yaroslav R.; Comas, Laurent; Boulahdour, Hatem; Cardot, Jean-Claude

    2007-02-01

    Positron emission tomography (PET) with [18F]-2-fluoro-deoxy-D-glucose (FDG) is being increasingly used in research. Isotope studies may be of help in an assessment of vasoactive potential of newly developed therapeutic preparations, including natural metabolites, like glycine. As a medicine, glycine was recently shown to have a positive therapeutic effect in the treatment of patients with neurological disorders based on vascular disturbances. By previous direct biomicroscopic investigations of pial microvessels in laboratory rats, an expressed vasodilatory effect of topically applied glycine was proved. The aim of this study was to evaluate the influence of glycine on the rat cerebral blood flow (CBF) using FDG-PET scan. A baseline study was started immediately after intravenous injection of 19 MBq of FDG in anesthetized rat. The PET images were acquired twice, one by one during 20 min. Two hours later, after sublingual application of glycine and the second FDG injection, the pair of PET scan was performed during 20 min as well. Finally, 4 days after the first studies, we repeated the PET scans in the same conditions after sublingual application of glycine. The quantitative analysis of FDG volume concentration (Bq/ml) in the rat brain demonstrated that in both studies after glycine administration, the FDG uptake increased at least 1.5 times in comparison with the baseline data. Moreover, the peak of the concentration was coming in more rapidly. These results confirm the enhancing effect of glycine on the rat CBF possibly because of its vasodilatory effect on brain microvessels. Therefore, FDG-PET technique contributes to better understanding of glycine pharmacokinetics.

  19. Correlative fluorescence and scanning transmission electron microscopy of quantum dot-labeled proteins on whole cells in liquid.

    PubMed

    Peckys, Diana B; Bandmann, Vera; de Jonge, Niels

    2014-01-01

    Correlative fluorescence microscopy combined with scanning transmission electron microscopy (STEM) of cells fully immersed in liquid is a new methodology with many application areas. Proteins, in live cells immobilized on microchips, are labeled with fluorescent quantum dot nanoparticles. In this protocol, the epidermal growth factor receptor (EGFR) is labeled. The cells are fixed after a selected labeling time, for example, 5 min as needed to form EGFR dimers. The microchip with cells is then imaged with fluorescence microscopy. Thereafter, STEM can be accomplished in two ways. The microchip with the labeled cells and one microchip with a spacer are assembled into a special microfluidic device and imaged with dedicated high-voltage STEM. Alternatively, thin edges of cells can be studied with environmental scanning electron microscopy with a STEM detector, by placing a microchip with cells in a cooled wet environment. © 2014 Elsevier Inc. All rights reserved.

  20. Comparison of prone versus supine 18F-FDG-PET of locally advanced breast cancer: Phantom and preliminary clinical studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, Jason M.; Rani, Sudheer D.; Li, Xia

    2015-07-15

    Purpose: Previous studies have demonstrated how imaging of the breast with patients lying prone using a supportive positioning device markedly facilitates longitudinal and/or multimodal image registration. In this contribution, the authors’ primary objective was to determine if there are differences in the standardized uptake value (SUV) derived from [{sup 18}F]fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) in breast tumors imaged in the standard supine position and in the prone position using a specialized positioning device. Methods: A custom positioning device was constructed to allow for breast scanning in the prone position. Rigid and nonrigid phantom studies evaluated differences in prone andmore » supine PET. Clinical studies comprised 18F-FDG-PET of 34 patients with locally advanced breast cancer imaged in the prone position (with the custom support) followed by imaging in the supine position (without the support). Mean and maximum values (SUV{sub peak} and SUV{sub max}, respectively) were obtained from tumor regions-of-interest for both positions. Prone and supine SUV were linearly corrected to account for the differences in 18F-FDG uptake time. Correlation, Bland–Altman, and nonparametric analyses were performed on uptake time-corrected and uncorrected data. Results: SUV from the rigid PET breast phantom imaged in the prone position with the support device was 1.9% lower than without the support device. In the nonrigid PET breast phantom, prone SUV with the support device was 5.0% lower than supine SUV without the support device. In patients, the median (range) difference in uptake time between prone and supine scans was 16.4 min (13.4–30.9 min), which was significantly—but not completely—reduced by the linear correction method. SUV{sub peak} and SUV{sub max} from prone versus supine scans were highly correlated, with concordance correlation coefficients of 0.91 and 0.90, respectively. Prone SUV{sub peak} and SUV{sub max} were significantly lower than supine in both original and uptake time-adjusted data across a range of index times (P < < 0.0001, Wilcoxon signed rank test). Before correcting for uptake time differences, Bland–Altman analyses revealed proportional bias between prone and supine measurements (SUV{sub peak} and SUV{sub max}) that increased with higher levels of FDG uptake. After uptake time correction, this bias was significantly reduced (P < 0.01). Significant prone-supine differences, with regard to the spatial distribution of lesions relative to isocenter, were observed between the two scan positions, but this was poorly correlated with the residual (uptake time-corrected) prone-supine SUV{sub peak} difference (P = 0.78). Conclusions: Quantitative 18F-FDG-PET/CT of the breast in the prone position is not deleteriously affected by the support device but yields SUV that is consistently lower than those obtained in the standard supine position. SUV differences between scans arising from FDG uptake time differences can be substantially reduced, but not removed entirely, with the current correction method. SUV from the two scan orientations is quantitatively different and should not be assumed equivalent or interchangeable within the same subject. These findings have clinical relevance in that they underscore the importance of patient positioning while scanning as a clinical variable that must be accounted for with longitudinal PET measurement, for example, in the assessment of treatment response.« less

  1. Multisite Reliability of MR-Based Functional Connectivity

    PubMed Central

    Noble, Stephanie; Scheinost, Dustin; Finn, Emily S.; Shen, Xilin; Papademetris, Xenophon; McEwen, Sarah C.; Bearden, Carrie E.; Addington, Jean; Goodyear, Bradley; Cadenhead, Kristin S.; Mirzakhanian, Heline; Cornblatt, Barbara A.; Olvet, Doreen M.; Mathalon, Daniel H.; McGlashan, Thomas H.; Perkins, Diana O.; Belger, Aysenil; Seidman, Larry J.; Thermenos, Heidi; Tsuang, Ming T.; van Erp, Theo G.M.; Walker, Elaine F.; Hamann, Stephan; Woods, Scott W.; Cannon, Tyrone D.; Constable, R. Todd

    2016-01-01

    Recent years have witnessed an increasing number of multisite MRI functional connectivity (fcMRI) studies. While multisite studies are an efficient way to speed up data collection and increase sample sizes, especially for rare clinical populations, any effects of site or MRI scanner could ultimately limit power and weaken results. Little data exists on the stability of functional connectivity measurements across sites and sessions. In this study, we assess the influence of site and session on resting state functional connectivity measurements in a healthy cohort of traveling subjects (8 subjects scanned twice at each of 8 sites) scanned as part of the North American Prodrome Longitudinal Study (NAPLS). Reliability was investigated in three types of connectivity analyses: (1) seed-based connectivity with posterior cingulate cortex (PCC), right motor cortex (RMC), and left thalamus (LT) as seeds; (2) the intrinsic connectivity distribution (ICD), a voxel-wise connectivity measure; and (3) matrix connectivity, a whole-brain, atlas-based approach assessing connectivity between nodes. Contributions to variability in connectivity due to subject, site, and day-of-scan were quantified and used to assess between-session (test-retest) reliability in accordance with Generalizability Theory. Overall, no major site, scanner manufacturer, or day-of-scan effects were found for the univariate connectivity analyses; instead, subject effects dominated relative to the other measured factors. However, summaries of voxel-wise connectivity were found to be sensitive to site and scanner manufacturer effects. For all connectivity measures, although subject variance was three times the site variance, the residual represented 60–80% of the variance, indicating that connectivity differed greatly from scan to scan independent of any of the measured factors (i.e., subject, site, and day-of-scan). Thus, for a single 5 min scan, reliability across connectivity measures was poor (ICC=0.07–0.17), but increases with increasing scan duration (ICC=0.21–0.36 at 25 min). The limited effects of site and scanner manufacturer support the use of multisite studies, such as NAPLS, as a viable means of collecting data on rare populations and increasing power in univariate functional connectivity studies. However, the results indicate that aggregation of fcMRI data across longer scan durations is necessary to increase the reliability of connectivity estimates at the single-subject level. PMID:27746386

  2. Characterization of a multi-axis ion chamber array.

    PubMed

    Simon, Thomas A; Kozelka, Jakub; Simon, William E; Kahler, Darren; Li, Jonathan; Liu, Chihray

    2010-11-01

    The aim of this work was to characterize a multi-axis ion chamber array (IC PROFILER; Sun Nuclear Corporation, Melbourne, FL, USA) that has the potential to simplify the acquisition of LINAC beam data. The IC PROFILER (or panel) measurement response was characterized with respect to radiation beam properties, including dose, dose per pulse, pulse rate frequency (PRF), and energy. Panel properties were also studied, including detector-calibration stability, power-on time, backscatter dependence, and the panel's agreement with water tank measurements [profiles, fractional depth dose (FDD), and output factors]. The panel's relative deviation was typically within (+/-) 1% of an independent (or nominal) response for all properties that were tested. Notable results were (a) a detectable relative field shape change of approximately 1% with linear accelerator PRF changes; (b) a large range in backscatter thickness had a minimal effect on the measured dose distribution (typically less than 1%); (c) the error spread in profile comparison between the panel and scanning water tank (Blue Phantom, CC13; IBA Schwarzenbruck, DE) was approximately (+/-) 0.75%. The ability of the panel to accurately reproduce water tank profiles, FDDs, and output factors is an indication of its abilities as a dosimetry system. The benefits of using the panel versus a scanning water tank are less setup time and less error susceptibility. The same measurements (including device setup and breakdown) for both systems took 180 min with the water tank versus 30 min with the panel. The time-savings increase as the measurement load is increased.

  3. Usefulness of free-breathing readout-segmented echo-planar imaging (RESOLVE) for detection of malignant liver tumors: comparison with single-shot echo-planar imaging (SS-EPI).

    PubMed

    Tokoro, Hirokazu; Fujinaga, Yasunari; Ohya, Ayumi; Ueda, Kazuhiko; Shiobara, Aya; Kitou, Yoshihiro; Ueda, Hitoshi; Kadoya, Masumi

    2014-10-01

    We aimed to clarify the usefulness of free-breathing readout-segmented echo-planar imaging (RESOLVE), which is multi-shot echo-planar imaging based on a 2D-navigator-based reacquisition technique, for detecting malignant liver tumor. In 77 patients with malignant liver tumors, free-breathing RESOLVE and respiratory-triggered single-shot echo-planar imaging (SS-EPI) at 3-T MR unit were performed. We set a scan time up to approximately 5 min (300s) before examination, measured actual scan time and assessed (1) susceptibility and (2) motion artifacts in the right and left liver lobes (3, no artifact; 1, marked), and (3) detectability of malignant liver tumors (3, good; 1, poor) using a 3-point scale. The median actual scan time of RESOLVE/SS-EPI was 365/423s. The median scores of each factor in RESOLVE/SS-EPI were as following in this order: (1) 3/2 (right lobe); 3/3 (left lobe), (2) 2/3 (right lobe); 1/2 (left lobe), and (3) 3/3, respectively. Significant differences were noted between RESOLVE and SS-EPI in all evaluated factors (P<0.05) except for susceptibility of left lobe and detectability of the lesions. Despite the effect of motion artifacts, RESOLVE provides a comparable detectability of the lesion and the advantage of reducing scanning time compared with SS-EPI. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  4. CVD-graphene for low equivalent series resistance in rGO/CVD-graphene/Ni-based supercapacitors.

    PubMed

    Kwon, Young Hwi; Kumar, Sunil; Bae, Joonho; Seo, Yongho

    2018-05-11

    Reduced equivalent series resistance (ESR) is necessary, particularly at a high current density, for high performance supercapacitors, and the interface resistance between the current collector and electrode material is one of the main components of ESR. In this report, we have optimized chemical vapor deposition-grown graphene (CVD-G) on a current collector (Ni-foil) using reduced graphene oxide as an active electrode material to fabricate an electric double layer capacitor with reduced ESR. The CVD-G was grown at different cooling rates-20 °C min -1 , 40 °C min -1 and 100 °C min -1 -to determine the optimum conditions. The lowest ESR, 0.38 Ω, was obtained for a cell with a 100 °C min -1 cooling rate, while the sample without a CVD-G interlayer exhibited 0.80 Ω. The CVD-G interlayer-based supercapacitors exhibited fast CD characteristics with high scan rates up to 10 Vs -1 due to low ESR. The specific capacitances deposited with CVD-G were in the range of 145.6 F g -1 -213.8 F g -1 at a voltage scan rate of 0.05 V s -1 . A quasi-rectangular behavior was observed in the cyclic voltammetry curves, even at very high scan rates of 50 and 100 V s -1 , for the cell with optimized CVD-G at higher cooling rates, i.e. 100 °C min -1 .

  5. Optimized in vivo detection of dopamine release using 18F-fallypride PET.

    PubMed

    Ceccarini, Jenny; Vrieze, Elske; Koole, Michel; Muylle, Tom; Bormans, Guy; Claes, Stephan; Van Laere, Koen

    2012-10-01

    The high-affinity D(2/3) PET radioligand (18)F-fallypride offers the possibility of measuring both striatal and extrastriatal dopamine release during activation paradigms. When a single (18)F-fallypride scanning protocol is used, task timing is critical to the ability to explore both striatal and extrastriatal dopamine release simultaneously. We evaluated the sensitivity and optimal timing of task administration for a single (18)F-fallypride PET protocol and the linearized simplified reference region kinetic model in detecting both striatal and extrastriatal reward-induced dopamine release, using human and simulation studies. Ten healthy volunteers underwent a single-bolus (18)F-fallypride PET protocol. A reward responsiveness learning task was initiated at 100 min after injection. PET data were analyzed using the linearized simplified reference region model, which accounts for time-dependent changes in (18)F-fallypride displacement. Voxel-based statistical maps, reflecting task-induced D(2/3) ligand displacement, and volume-of-interest-based analysis were performed to localize areas with increased ligand displacement after task initiation, thought to be proportional to changes in endogenous dopamine release (γ parameter). Simulated time-activity curves for baseline and hypothetical dopamine release functions (different peak heights of dopamine and task timings) were generated using the enhanced receptor-binding kinetic model to investigate γ as a function of these parameters. The reward task induced increased ligand displacement in extrastriatal regions of the reward circuit, including the medial orbitofrontal cortex, ventromedial prefrontal cortex, and dorsal anterior cingulate cortex. For task timing of 100 min, ligand displacement was found for the striatum only when peak height of dopamine was greater than 240 nM, whereas for frontal regions, γ was always positive for all task timings and peak heights of dopamine. Simulation results for a peak height of dopamine of 200 nM showed that an effect of striatal ligand displacement could be detected only when task timing was greater than 120 min. The prefrontal and anterior cingulate cortices are involved in reward responsiveness that can be measured using (18)F-fallypride PET in a single scanning session. To measure both striatal and extrastriatal dopamine release, the height of dopamine released and task timing need to be considered in designing activation studies depending on regional D(2/3) density.

  6. Quantification of 18F-fluorocholine kinetics in patients with prostate cancer.

    PubMed

    Verwer, Eline E; Oprea-Lager, Daniela E; van den Eertwegh, Alfons J M; van Moorselaar, Reindert J A; Windhorst, Albert D; Schwarte, Lothar A; Hendrikse, N Harry; Schuit, Robert C; Hoekstra, Otto S; Lammertsma, Adriaan A; Boellaard, Ronald

    2015-03-01

    Choline kinase is upregulated in prostate cancer, resulting in increased (18)F-fluoromethylcholine uptake. This study used pharmacokinetic modeling to validate the use of simplified methods for quantification of (18)F-fluoromethylcholine uptake in a routine clinical setting. Forty-minute dynamic PET/CT scans were acquired after injection of 204 ± 9 MBq of (18)F-fluoromethylcholine, from 8 patients with histologically proven metastasized prostate cancer. Plasma input functions were obtained using continuous arterial blood-sampling as well as using image-derived methods. Manual arterial blood samples were used for calibration and correction for plasma-to-blood ratio and metabolites. Time-activity curves were derived from volumes of interest in all visually detectable lymph node metastases. (18)F-fluoromethylcholine kinetics were studied by nonlinear regression fitting of several single- and 2-tissue plasma input models to the time-activity curves. Model selection was based on the Akaike information criterion and measures of robustness. In addition, the performance of several simplified methods, such as standardized uptake value (SUV), was assessed. Best fits were obtained using an irreversible compartment model with blood volume parameter. Parent fractions were 0.12 ± 0.4 after 20 min, necessitating individual metabolite corrections. Correspondence between venous and arterial parent fractions was low as determined by the intraclass correlation coefficient (0.61). Results for image-derived input functions that were obtained from volumes of interest in blood-pool structures distant from tissues of high (18)F-fluoromethylcholine uptake yielded good correlation to those for the blood-sampling input functions (R(2) = 0.83). SUV showed poor correlation to parameters derived from full quantitative kinetic analysis (R(2) < 0.34). In contrast, lesion activity concentration normalized to the integral of the blood activity concentration over time (SUVAUC) showed good correlation (R(2) = 0.92 for metabolite-corrected plasma; 0.65 for whole-blood activity concentrations). SUV cannot be used to quantify (18)F-fluoromethylcholine uptake. A clinical compromise could be SUVAUC derived from 2 consecutive static PET scans, one centered on a large blood-pool structure during 0-30 min after injection to obtain the blood activity concentrations and the other a whole-body scan at 30 min after injection to obtain lymph node activity concentrations. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  7. Low cycle fatigue and creep fatigue interaction behavior of 9Cr-0.5Mo-1.8W-V-Nb heat-resistant steel at high temperature

    NASA Astrophysics Data System (ADS)

    Wang, Xiaowei; Zhang, Wei; Gong, Jianming; Wahab, Magd Abdel

    2018-07-01

    In this paper, Low Cycle Fatigue (LCF) and Creep-Fatigue Interaction (CFI) behavior of 9Cr-0.5Mo-1.8 W-V-Nb heat-resistant steel (ASME Grade P92 steel) at elevated temperature of 600 °C are investigated. Strain controlled LCF tests are conducted in fully reversed triangular waveform at different strain amplitudes ranging from 0.2% to 0.8%. CFI tests are conducted at 0.4% strain amplitude in trapezoid waveform with tensile hold time varying from 1 min to 60 min and compressive hold time varying from 1 min to 10 min. During LCF and CFI loadings, the evolution of cyclic stress, mean stress and stress relaxation behavior are investigated. It turns out that the softening behavior and lifetime degradation are dependent on strain amplitude, hold time and hold direction. In addition, the microstructure evolution and fracture behavior are characterized by optical, scanning and transmission electron microscope. The initial rapid softening behavior is attributed to the quick elimination of low angle boundaries, whereas no obvious microstructure alteration appears in the stable stage. Fracture behavior analysis reveals creep voids in long-term CFI tests facilitates the initiation and propagation of secondary cracks. The different responses of outer surface oxidation layer during cycling provides an explanation for severer damage of compressive hold and also accounts for the observed various fracture behavior of failed samples.

  8. Enhanced Ethanol Gas Sensing Properties of SnO2-Core/ZnO-Shell Nanostructures

    PubMed Central

    Tharsika, T.; Haseeb, A. S. M. A.; Akbar, Sheikh A.; Sabri, Mohd Faizul Mohd; Hoong, Wong Yew

    2014-01-01

    An inexpensive single-step carbon-assisted thermal evaporation method for the growth of SnO2-core/ZnO-shell nanostructures is described, and the ethanol sensing properties are presented. The structure and phases of the grown nanostructures are investigated by field-emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM) and X-ray diffraction (XRD) techniques. XRD analysis indicates that the core-shell nanostructures have good crystallinity. At a lower growth duration of 15 min, only SnO2 nanowires with a rectangular cross-section are observed, while the ZnO shell is observed when the growth time is increased to 30 min. Core-shell hierarchical nanostructures are present for a growth time exceeding 60 min. The growth mechanism for SnO2-core/ZnO-shell nanowires and hierarchical nanostructures are also discussed. The sensitivity of the synthesized SnO2-core/ZnO-shell nanostructures towards ethanol sensing is investigated. Results show that the SnO2-core/ZnO-shell nanostructures deposited at 90 min exhibit enhanced sensitivity to ethanol. The sensitivity of SnO2-core/ZnO-shell nanostructures towards 20 ppm ethanol gas at 400 °C is about ∼5-times that of SnO2 nanowires. This improvement in ethanol gas response is attributed to high active sensing sites and the synergistic effect of the encapsulation of SnO2 by ZnO nanostructures. PMID:25116903

  9. Ultrashort pulsed laser (USPL) application in dentistry: basic investigations of ablation rates and thresholds on oral hard tissue and restorative materials.

    PubMed

    Schelle, Florian; Polz, Sebastian; Haloui, Hatim; Braun, Andreas; Dehn, Claudia; Frentzen, Matthias; Meister, Jörg

    2014-11-01

    Modern ultrashort pulse lasers with scanning systems provide a huge set of parameters affecting the suitability for dental applications. The present study investigates thresholds and ablation rates of oral hard tissues and restorative materials with a view towards a clinical application system. The functional system consists of a 10 W Nd:YVO4 laser emitting pulses with a duration of 8 ps at 1,064 nm. Measurements were performed on dentin, enamel, ceramic, composite, and mammoth ivory at a repetition rate of 500 kHz. By employing a scanning system, square-shaped cavities with an edge length of 1 mm were created. Ablation threshold and rate measurements were assessed by variation of the applied fluence. Examinations were carried out employing a scanning electron microscope and optical profilometer. Irradiation time was recorded by the scanner software in order to calculate the overall ablated volume per time. First high power ablation rate measurements were performed employing a laser source with up to 50 W. Threshold values in the range of 0.45 J/cm(2) (composite) to 1.54 J/cm(2) (enamel) were observed. Differences between any two materials are statistically significant (p < 0.05). Preparation speeds up to 37.53 mm(3)/min (composite) were achieved with the 10 W laser source and differed statistically significant for any two materials (p < 0.05) with the exception of dentin and mammoth ivory (p > 0.05). By employing the 50 W laser source, increased rates up to ∼50 mm(3)/min for dentin were obtained. The results indicate that modern USPL systems provide sufficient ablation rates to be seen as a promising technology for dental applications.

  10. High intensity intermittent games-based activity and adolescents' cognition: moderating effect of physical fitness.

    PubMed

    Cooper, Simon B; Dring, Karah J; Morris, John G; Sunderland, Caroline; Bandelow, Stephan; Nevill, Mary E

    2018-05-08

    An acute bout of exercise elicits a beneficial effect on subsequent cognitive function in adolescents. The effect of games-based activity, an ecologically valid and attractive exercise model for young people, remains unknown; as does the moderating effect of fitness on the acute exercise-cognition relationship. Therefore, the aim of the present study was to examine the effect of games-based activity on subsequent cognition in adolescents, and the moderating effect of fitness on this relationship. Following ethical approval, 39 adolescents (12.3 ± 0.7 year) completed an exercise and resting trial in a counterbalanced, randomised crossover design. During familiarisation, participants completed a multi-stage fitness test to predict VO 2 peak. The exercise trial consisted of 60-min games-based activity (basketball), during which heart rate was 158 ± 11 beats∙min - 1 . A battery of cognitive function tests (Stroop test, Sternberg paradigm, trail making and d2 tests) were completed 30-min before, immediately following and 45-min following the basketball. Response times on the complex level of the Stroop test were enhanced both immediately (p = 0.021) and 45-min (p = 0.035) post-exercise, and response times on the five item level of the Sternberg paradigm were enhanced immediately post-exercise (p = 0.023). There were no effects on the time taken to complete the trail making test or any outcome of the d2 test. In particular, response times were enhanced in the fitter adolescents 45-min post-exercise on both levels of the Stroop test (simple, p = 0.005; complex, p = 0.040) and on the three item level of the Sternberg paradigm immediately (p = 0.017) and 45-min (p = 0.008) post-exercise. Games-based activity enhanced executive function and working memory scanning speed in adolescents, an effect particularly evident in fitter adolescents, whilst the high intensity intermittent nature of games-based activity may be too demanding for less fit children.

  11. Cone-beam computed tomography fusion and navigation for real-time positron emission tomography-guided biopsies and ablations: a feasibility study.

    PubMed

    Abi-Jaoudeh, Nadine; Mielekamp, Peter; Noordhoek, Niels; Venkatesan, Aradhana M; Millo, Corina; Radaelli, Alessandro; Carelsen, Bart; Wood, Bradford J

    2012-06-01

    To describe a novel technique for multimodality positron emission tomography (PET) fusion-guided interventions that combines cone-beam computed tomography (CT) with PET/CT before the procedure. Subjects were selected among patients scheduled for a biopsy or ablation procedure. The lesions were not visible with conventional imaging methods or did not have uniform uptake on PET. Clinical success was defined by adequate histopathologic specimens for molecular profiling or diagnosis and by lack of enhancement on follow-up imaging for ablation procedures. Time to target (time elapsed between the completion of the initial cone-beam CT scan and first tissue sample or treatment), total procedure time (time from the moment the patient was on the table until the patient was off the table), and number of times the needle was repositioned were recorded. Seven patients underwent eight procedures (two ablations and six biopsies). Registration and procedures were completed successfully in all cases. Clinical success was achieved in all biopsy procedures and in one of the two ablation procedures. The needle was repositioned once in one biopsy procedure only. On average, the time to target was 38 minutes (range 13-54 min). Total procedure time was 95 minutes (range 51-240 min, which includes composite ablation). On average, fluoroscopy time was 2.5 minutes (range 1.3-6.2 min). An integrated cone-beam CT software platform can enable PET-guided biopsies and ablation procedures without the need for additional specialized hardware. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  12. Improvement of adhesion and barrier properties of biomedical stainless steel by deposition of YSZ coatings using RF magnetron sputtering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sánchez-Hernández, Z.E.; CICATA—Altamira, IPN. Grupo CIAMS, Km 14.5, Carretera Tampico-Puerto Industrial Altamira, C. P. 89600, Altamira, Tamps, México; Domínguez-Crespo, M.A., E-mail: mdominguezc@ipn.mx

    The AISI 316L stainless steel (SS) has been widely used in both artificial knee and hip joints in biomedical applications. In the present study, yttria stabilized zirconia (YSZ, ZrO{sub 2} + 8% Y{sub 2}O{sub 3}) films were deposited on AISI 316L SS by radio-frequency magnetron sputtering using different power densities (50–250 W) and deposition times (30–120 min) from a YSZ target. The crystallographic orientation and surface morphology were studied using X-ray diffraction (XRD), scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The effects of the surface modification on the corrosion performance of AISI 316L SS were evaluated in phosphatemore » buffered saline (PBS) solution using an electrochemical test on both the virgin and coated samples. The YSZ coatings have a (111) preferred orientation during crystal growth along the c-axis for short deposition times (30–60 min), whereas a polycrystalline structure forms during deposition times from 90 to 120 min. The corrosion protective character of the YSZ coatings depends on the crystal size and film thickness. A significant increase in adhesion and corrosion resistance by at least a factor of 46 and a higher breakdown potential were obtained for the deposited coatings at 200 W (120 min). - Highlights: • Well-formed and protective YSZ coatings were achieved on AISI 316L SS substrates. • Films grown at high power and long deposition time have polycrystalline structures. • The crystal size varies from ∼ 5 to 30 nm as both power and deposition time increased. • The differences of corrosion resistance are attributed to internal film structure.« less

  13. Quantitative and Visual Assessments toward Potential Sub-mSv or Ultrafast FDG PET Using High-Sensitivity TOF PET in PET/MRI.

    PubMed

    Behr, Spencer C; Bahroos, Emma; Hawkins, Randall A; Nardo, Lorenzo; Ravanfar, Vahid; Capbarat, Emily V; Seo, Youngho

    2018-06-01

    Newer high-performance time-of-flight (TOF) positron emission tomography (PET) systems have the capability to preserve diagnostic image quality with low count density, while maintaining a high raw photon detection sensitivity that would allow for a reduction in injected dose or rapid data acquisition. To assess this, we performed quantitative and visual assessments of the PET images acquired using a highly sensitive (23.3 cps/kBq) large field of view (25-cm axial) silicon photomultiplier (SiPM)-based TOF PET (400-ps timing resolution) integrated with 3 T-MRI in comparison to PET images acquired on non-TOF PET/x-ray computed tomography (CT) systems. Whole-body 2-deoxy-2-[ 18 F]fluoro-D-glucose ([ 18 F]FDG) PET/CT was acquired for 15 patients followed by whole body PET/magnetic resonance imaging (MRI) with an average injected dose of 325 ± 84 MBq. The PET list mode data from PET/MRI were reconstructed using full datasets (4 min/bed) and reduced datasets (2, 1, 0.5, and 0.25 min/bed). Qualitative assessment between PET/CT and PET/MR images were made. A Likert-type scale between 1 and 5, 1 for non-diagnostic, 3 equivalent to PET/CT, and 5 superior quality, was used. Maximum and mean standardized uptake values (SUV max and SUV mean ) of normal tissues and lesions detected were measured and compared. Mean visual assessment scores were 3.54 ± 0.32, 3.62 ± 0.38, and 3.69 ± 0.35 for the brain and 3.05 ± 0.49, 3.71 ± 0.45, and 4.14 ± 0.44 for the whole-body maximum intensity projections (MIPs) for 1, 2, and 4 min/bed PET/MR images, respectively. The SUV mean values for normal tissues were lower and statistically significant for images acquired at 4, 2, 1, 0.5, and 0.25 min/bed on the PET/MR, with values of - 18 ± 28 % (p < 0.001), - 16 ± 29 % (p = 0.001), - 16 ± 31 % (p = 0.002), - 14 ± 35 % (p < 0.001), and - 13 ± 34 % (p = 0.002), respectively. SUV max and SUV peak values of all lesions were higher and statistically significant (p < 0.05) for 4, 2, 1, 0.50, and 0.25 min/bed PET/MR datasets. High-sensitivity TOF PET showed comparable but still better visual image quality even at a much reduced activity in comparison to lower-sensitivity non-TOF PET. Our data translates to a seven times reduction in either injection dose for the same time or total scan time for the same injected dose. This "ultra-sensitivity" PET system provides a path to clinically acceptable extremely low-dose FDG PET studies (e.g., sub 1 mCi injection or sub-mSv effective dose) or PET studies as short as 1 min/bed (e.g., 6 min of total scan time) to cover whole body without compromising diagnostic performance.

  14. Fast 3D magnetic resonance fingerprinting for a whole-brain coverage.

    PubMed

    Ma, Dan; Jiang, Yun; Chen, Yong; McGivney, Debra; Mehta, Bhairav; Gulani, Vikas; Griswold, Mark

    2018-04-01

    The purpose of this study was to accelerate the acquisition and reconstruction time of 3D magnetic resonance fingerprinting scans. A 3D magnetic resonance fingerprinting scan was accelerated by using a single-shot spiral trajectory with an undersampling factor of 48 in the x-y plane, and an interleaved sampling pattern with an undersampling factor of 3 through plane. Further acceleration came from reducing the waiting time between neighboring partitions. The reconstruction time was accelerated by applying singular value decomposition compression in k-space. Finally, a 3D premeasured B 1 map was used to correct for the B 1 inhomogeneity. The T 1 and T 2 values of the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI phantom showed a good agreement with the standard values, with an average concordance correlation coefficient of 0.99, and coefficient of variation of 7% in the repeatability scans. The results from in vivo scans also showed high image quality in both transverse and coronal views. This study applied a fast acquisition scheme for a fully quantitative 3D magnetic resonance fingerprinting scan with a total acceleration factor of 144 as compared with the Nyquist rate, such that 3D T 1 , T 2 , and proton density maps can be acquired with whole-brain coverage at clinical resolution in less than 5 min. Magn Reson Med 79:2190-2197, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  15. Influence of concentration, time and method of application of citric acid and sodium citrate in root conditioning

    PubMed Central

    CAVASSIM, Rodrigo; LEITE, Fábio Renato Manzolli; ZANDIM, Daniela Leal; DANTAS, Andrea Abi Rached; RACHED, Ricardo Samih Georges Abi; SAMPAIO, José Eduardo Cezar

    2012-01-01

    Objective The aim of this study was to establish the parameters of concentration, time and mode of application of citric acid and sodium citrate in relation to root conditioning. Material and Methods A total of 495 samples were obtained and equally distributed among 11 groups (5 for testing different concentrations of citric acid, 5 for testing different concentrations of sodium citrate and 1 control group). After laboratorial processing, the samples were analyzed under scanning electron microscopy. A previously calibrated and blind examiner evaluated micrographs of the samples. Non-parametric statistical analysis was performed to analyze the data obtained. Results Brushing 25% citric acid for 3 min, promoted greater exposure of collagen fibers in comparison with the brushing of 1% citric acid for 1 minute and its topical application at 1% for 3 min. Sodium citrate exposed collagen fibers in a few number of samples. Conclusion Despite the lack of statistical significance, better results for collagen exposure were obtained with brushing application of 25% citric acid for 3 min than with other application parameter. Sodium citrate produced a few number of samples with collagen exposure, so it is not indicated for root conditioning. PMID:22858707

  16. Time-efficiency analysis of the treatment with monolithic implant crowns in a digital workflow: a randomized controlled trial.

    PubMed

    Joda, Tim; Brägger, Urs

    2016-11-01

    The aim of the randomized controlled trial was to analyze time-efficiency of a treatment with implant crowns made of monolithic lithium disilicate (LS2) plus titanium base vs. porcelain fuse to zirconium dioxide (ZrO 2 ) in a digital workflow. Twenty study participants were included for single-tooth replacement in premolar and molar sites. Baseline was the start of the prosthetic treatment. All patients received transocclusal screw-retained implant reconstructions on a soft tissue level-type implant. The 3D implant position was captured with intraoral optical scanning (IOS). After randomization, ten patients were restored with CAD-/CAM-produced monolithic LS2-crowns bonded to prefabricated titanium abutments without any physical models (test), and ten patients with CAD-/CAM-fabricated ZrO 2 -suprastructures and hand-layered ceramic veneering with milled master models (control). Every single clinical and laboratory work step was timed in minutes and then analyzed for time-efficiency with Wilcoxon Rank Sum Tests. Direct costs were assessed for laboratory fees for first line production in Swiss Francs (CHF). Two clinical appointments were necessary for IOS and seating of all implant crowns. The mean total production time, as the sum of clinical plus laboratory work steps, was significantly different, resulting in 75.3 min (SD ± 2.1) for test and 156.6 min (SD ± 4.6) for control [P = 0.0001]. Analysis for clinical treatment sessions showed a significantly shorter mean chair time for the complete digital workflow of 20.8 min (SD ± 0.3) compared to 24.1 min (SD ± 1.1) [P = 0.001]. Even more obvious were the results for the mean laboratory work time with a significant reduction of 54.5 min (SD ± 4.9) vs. 132.5 min (SD ± 8.7), respectively [P = 0.0001]. The test workflow was more time-efficient than the controls for implant-supported crowns; notably, laboratory fabrication steps could be effectively shortened with the digital process of monolithic LS2 plus titanium base resulting in more than 30% reduced overall treatment costs. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. High pressure intensification of cassava resistant starch (RS3) yields.

    PubMed

    Lertwanawatana, Proyphon; Frazier, Richard A; Niranjan, Keshavan

    2015-08-15

    Cassava starch, typically, has resistant starch type 3 (RS3) content of 2.4%. This paper shows that the RS3 yields can be substantially enhanced by debranching cassava starch using pullulanase followed by high pressure or cyclic high-pressure annealing. RS3 yield of 41.3% was obtained when annealing was carried out at 400MPa/60°C for 15 min, whereas it took nearly 8h to obtain the same yield under conventional atmospheric annealing at 60°C. The yield of RS3 could be further significantly increased by annealing under 400 MPa/60°C pressure for 15 min followed by resting at atmospheric pressure for 3h 45 min, and repeating this cycle for up to six times. Microstructural surface analysis of the product under a scanning electron microscope showed an increasingly rigid density of the crystalline structure formed, confirming higher RS3 content. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Influence of Solution Treatment Duration on Microstructural Features of an Industrial Forged UNS S32750/1.4410/F53 Super Duplex Stainless Steel (SDSS) Alloy

    NASA Astrophysics Data System (ADS)

    Cojocaru, Vasile Dănuţ; Răducanu, Doina; Angelescu, Mariana Lucia; Vintilă, Adrian Nicolae; Şerban, Nicolae; Dan, Ioan; Cojocaru, Elisabeta Mirela; Cinca, Ion

    2017-08-01

    The microstructural changes induced by solution treatment of an industrial forged F53 Super Duplex Stainless Steel alloy were studied, in order to emphasize how component phases are influenced by heat treatment temperature and duration. The solution treatment was done at a temperature of 1100°C, with variable holding times: 0.6 ks (10 min), 3.6 ks (60 min) and 10.8 ks (180 min). Scanning electron microscopy-electron backscattered diffraction was used as main characterization technique, to obtain and analyse data referring to microstructural features, such as: nature and morphology of constituent phases, average grain-size and grain misorientation. It was shown that in all studied cases the microstructure consisted of a mixture of about 45% δ-Fe (ferrite) and 55% γ-Fe (austenite). Besides δ-Fe and γ-Fe phases, other phases were also identified, such as τ-phase (chromium-iron carbide), σ-phase (chromium-iron) and δ-(Cr-Fe) (ferrite).

  19. Effect of high-pressure treatment on the structural and rheological properties of resistant corn starch/locust bean gum mixtures.

    PubMed

    Hussain, Raza; Vatankhah, Hamed; Singh, Ajaypal; Ramaswamy, Hosahalli S

    2016-10-05

    In this study, effects of a 30min high pressure (HP) treatment (200-600MPa) at room temperature on the rheological, thermal and morphological properties of resistant corn starch (RS) (5% w/w) and locust bean gum (LBG) (0.25, 0.50 and 1.0% w/v) dispersions were evaluated. Results showed that the storage modulus (G'), loss modulus (G''), and apparent viscosity values of starch/gum (RS/LBG) mixtures were enhanced with an increase pressure level, and demonstrated a bi-phasic behavior. HP treated RS/LBG samples were predominantly either solid like (G'>G'') or viscous (G''>G'), depending on the pressure level and LBG concentrations. Differential scanning calorimetry (DSC) analysis of the pressurized mixtures showed a major effect on gelatinization temperatures (To, Tp,), and it was observed that RS/LBG mixtures gelatinized completely at ≥400MPa with a 30min holding time. Confocal laser scanning microscopy (CLSM) images confirmed that at 600MPa, RS/LBG mixtures retained granular structures and their complete disintegration was not observed even at the endpoint of the gelatinization. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. CAIPIRINHA accelerated SPACE enables 10-min isotropic 3D TSE MRI of the ankle for optimized visualization of curved and oblique ligaments and tendons.

    PubMed

    Kalia, Vivek; Fritz, Benjamin; Johnson, Rory; Gilson, Wesley D; Raithel, Esther; Fritz, Jan

    2017-09-01

    To test the hypothesis that a fourfold CAIPIRINHA accelerated, 10-min, high-resolution, isotropic 3D TSE MRI prototype protocol of the ankle derives equal or better quality than a 20-min 2D TSE standard protocol. Following internal review board approval and informed consent, 3-Tesla MRI of the ankle was obtained in 24 asymptomatic subjects including 10-min 3D CAIPIRINHA SPACE TSE prototype and 20-min 2D TSE standard protocols. Outcome variables included image quality and visibility of anatomical structures using 5-point Likert scales. Non-parametric statistical testing was used. P values ≤0.001 were considered significant. Edge sharpness, contrast resolution, uniformity, noise, fat suppression and magic angle effects were without statistical difference on 2D and 3D TSE images (p > 0.035). Fluid was mildly brighter on intermediate-weighted 2D images (p < 0.001), whereas 3D images had substantially less partial volume, chemical shift and no pulsatile-flow artifacts (p < 0.001). Oblique and curved planar 3D images resulted in mildly-to-substantially improved visualization of joints, spring, bifurcate, syndesmotic, collateral and sinus tarsi ligaments, and tendons (p < 0.001, respectively). 3D TSE MRI with CAIPIRINHA acceleration enables high-spatial resolution oblique and curved planar MRI of the ankle and visualization of ligaments, tendons and joints equally well or better than a more time-consuming anisotropic 2D TSE MRI. • High-resolution 3D TSE MRI improves visualization of ankle structures. • Limitations of current 3D TSE MRI include long scan times. • 3D CAIPIRINHA SPACE allows now a fourfold-accelerated data acquisition. • 3D CAIPIRINHA SPACE enables high-spatial-resolution ankle MRI within 10 min. • 10-min 3D CAIPIRINHA SPACE produces equal-or-better quality than 20-min 2D TSE.

  1. High-resolution ultrashort echo time (UTE) imaging on human knee with AWSOS sequence at 3.0 T.

    PubMed

    Qian, Yongxian; Williams, Ashley A; Chu, Constance R; Boada, Fernando E

    2012-01-01

    To demonstrate the technical feasibility of high-resolution (0.28-0.14 mm) ultrashort echo time (UTE) imaging on human knee at 3T with the acquisition-weighted stack of spirals (AWSOS) sequence. Nine human subjects were scanned on a 3T MRI scanner with an 8-channel knee coil using the AWSOS sequence and isocenter positioning plus manual shimming. High-resolution UTE images were obtained on the subject knees at TE = 0.6 msec with total acquisition time of 5.12 minutes for 60 slices at an in-plane resolution of 0.28 mm and 10.24 minutes for 40 slices at an in-plane resolution of 0.14 mm. Isocenter positioning, manual shimming, and the 8-channel array coil helped minimize image distortion and achieve high signal-to-noise ratio (SNR). It is technically feasible on a clinical 3T MRI scanner to perform UTE imaging on human knee at very high spatial resolutions (0.28-0.14 mm) within reasonable scan time (5-10 min) using the AWSOS sequence. Copyright © 2011 Wiley Periodicals, Inc.

  2. Assessment of safety, efficacy, and dosimetry of a novel 18-kDa translocator protein ligand, [11C]CB184, in healthy human volunteers.

    PubMed

    Sakata, Muneyuki; Ishibashi, Kenji; Imai, Masamichi; Wagatsuma, Kei; Ishii, Kenji; Hatano, Kentaro; Ishiwata, Kiichi; Toyohara, Jun

    2017-12-01

    N,N-di-n-propyl-2-[2-(4-[ 11 C]methoxyphenyl)-6,8-dichloroimidazol[1,2-a]pyridine-3-yl]acetamide ([ 11 C]CB184) is a novel selective radioligand for the 18-kD translocator protein (TSPO), which is upregulated in activated microglia in the brain, and may be useful in positron emission tomography (PET). We examined the safety, radiation dosimetry, and initial brain imaging with [ 11 C]CB184 in healthy human volunteers. Dynamic [ 11 C]CB184 PET scans (90 min) were performed in five healthy male subjects. During the scan, arterial blood was sampled at various time intervals, and the fraction of the parent compound in plasma was determined with high-performance liquid chromatography. No serious adverse events occurred in any of the subjects throughout the study period. [ 11 C]CB184 was metabolized in the periphery: 36.7% ± 5.7% of the radioactivity in plasma was detected as the unchanged form after 60 min. The total distribution volume (V T ) was estimated with a two-tissue compartment model. The V T of [ 11 C]CB184 was highest in the thalamus (5.1 ± 0.4), followed by the cerebellar cortex (4.4 ± 0.2), and others. Although regional differences were small, the observed [ 11 C]CB184 binding pattern was consistent with the TSPO distribution in the normal human brain. Radiation dosimetry was determined in three healthy male subjects using a serial whole-body PET scan acquired over 2 h after [ 11 C]CB184 injection. [ 11 C]CB184 PET demonstrated high uptake in the gallbladder at a later time (>60 min). In urine obtained approximately 100 min post-injection, 0.3% of the total injected radioactivity was recovered, indicating hepatobiliary excretion of radioactivity. The absorbed dose (μGy/MBq) was highest in the kidneys (21.0 ± 0.5) followed by the lungs (16.8 ± 2.7), spleen (16.6 ± 6.6), and pancreas (16.5 ± 2.2). The estimated effective dose for [ 11 C]CB184 was 5.9 ± 0.6 μSv/MBq. This initial evaluation indicated that [ 11 C]CB184 is feasible for imaging of TSPO in the brain.

  3. Fast CSF MRI for brain segmentation; Cross-validation by comparison with 3D T1-based brain segmentation methods

    PubMed Central

    de Bresser, Jeroen; Hendrikse, Jeroen; Siero, Jeroen C. W.; Petersen, Esben T.; De Vis, Jill B.

    2018-01-01

    Objective In previous work we have developed a fast sequence that focusses on cerebrospinal fluid (CSF) based on the long T2 of CSF. By processing the data obtained with this CSF MRI sequence, brain parenchymal volume (BPV) and intracranial volume (ICV) can be automatically obtained. The aim of this study was to assess the precision of the BPV and ICV measurements of the CSF MRI sequence and to validate the CSF MRI sequence by comparison with 3D T1-based brain segmentation methods. Materials and methods Ten healthy volunteers (2 females; median age 28 years) were scanned (3T MRI) twice with repositioning in between. The scan protocol consisted of a low resolution (LR) CSF sequence (0:57min), a high resolution (HR) CSF sequence (3:21min) and a 3D T1-weighted sequence (6:47min). Data of the HR 3D-T1-weighted images were downsampled to obtain LR T1-weighted images (reconstructed imaging time: 1:59 min). Data of the CSF MRI sequences was automatically segmented using in-house software. The 3D T1-weighted images were segmented using FSL (5.0), SPM12 and FreeSurfer (5.3.0). Results The mean absolute differences for BPV and ICV between the first and second scan for CSF LR (BPV/ICV: 12±9/7±4cc) and CSF HR (5±5/4±2cc) were comparable to FSL HR (9±11/19±23cc), FSL LR (7±4, 6±5cc), FreeSurfer HR (5±3/14±8cc), FreeSurfer LR (9±8, 12±10cc), and SPM HR (5±3/4±7cc), and SPM LR (5±4, 5±3cc). The correlation between the measured volumes of the CSF sequences and that measured by FSL, FreeSurfer and SPM HR and LR was very good (all Pearson’s correlation coefficients >0.83, R2 .67–.97). The results from the downsampled data and the high-resolution data were similar. Conclusion Both CSF MRI sequences have a precision comparable to, and a very good correlation with established 3D T1-based automated segmentations methods for the segmentation of BPV and ICV. However, the short imaging time of the fast CSF MRI sequence is superior to the 3D T1 sequence on which segmentation with established methods is performed. PMID:29672584

  4. Fast CSF MRI for brain segmentation; Cross-validation by comparison with 3D T1-based brain segmentation methods.

    PubMed

    van der Kleij, Lisa A; de Bresser, Jeroen; Hendrikse, Jeroen; Siero, Jeroen C W; Petersen, Esben T; De Vis, Jill B

    2018-01-01

    In previous work we have developed a fast sequence that focusses on cerebrospinal fluid (CSF) based on the long T2 of CSF. By processing the data obtained with this CSF MRI sequence, brain parenchymal volume (BPV) and intracranial volume (ICV) can be automatically obtained. The aim of this study was to assess the precision of the BPV and ICV measurements of the CSF MRI sequence and to validate the CSF MRI sequence by comparison with 3D T1-based brain segmentation methods. Ten healthy volunteers (2 females; median age 28 years) were scanned (3T MRI) twice with repositioning in between. The scan protocol consisted of a low resolution (LR) CSF sequence (0:57min), a high resolution (HR) CSF sequence (3:21min) and a 3D T1-weighted sequence (6:47min). Data of the HR 3D-T1-weighted images were downsampled to obtain LR T1-weighted images (reconstructed imaging time: 1:59 min). Data of the CSF MRI sequences was automatically segmented using in-house software. The 3D T1-weighted images were segmented using FSL (5.0), SPM12 and FreeSurfer (5.3.0). The mean absolute differences for BPV and ICV between the first and second scan for CSF LR (BPV/ICV: 12±9/7±4cc) and CSF HR (5±5/4±2cc) were comparable to FSL HR (9±11/19±23cc), FSL LR (7±4, 6±5cc), FreeSurfer HR (5±3/14±8cc), FreeSurfer LR (9±8, 12±10cc), and SPM HR (5±3/4±7cc), and SPM LR (5±4, 5±3cc). The correlation between the measured volumes of the CSF sequences and that measured by FSL, FreeSurfer and SPM HR and LR was very good (all Pearson's correlation coefficients >0.83, R2 .67-.97). The results from the downsampled data and the high-resolution data were similar. Both CSF MRI sequences have a precision comparable to, and a very good correlation with established 3D T1-based automated segmentations methods for the segmentation of BPV and ICV. However, the short imaging time of the fast CSF MRI sequence is superior to the 3D T1 sequence on which segmentation with established methods is performed.

  5. Technical Note: Intrafractional changes in time lag relationship between anterior-posterior external and superior-inferior internal motion signals in abdominal tumor sites.

    PubMed

    Regmi, Rajesh; Lovelock, D Michael; Zhang, Pengpeng; Pham, Hai; Xiong, Jianping; Yorke, Ellen D; Goodman, Karyn A; Wu, Abraham J; Mageras, Gig S

    2015-06-01

    To investigate constancy, within a treatment session, of the time lag relationship between implanted markers in abdominal tumors and an external motion surrogate. Six gastroesophageal junction and three pancreatic cancer patients (IRB-approved protocol) received two cone-beam CTs (CBCT), one before and one after treatment. Time between scans was less than 30 min. Each patient had at least one implanted fiducial marker near the tumor. In all scans, abdominal displacement (Varian RPM) was recorded as the external motion signal. Purpose-built software tracked fiducials, representing internal signal, in CBCT projection images. Time lag between superior-inferior (SI) internal and anterior-posterior external signals was found by maximizing the correlation coefficient in each breathing cycle and averaging over all cycles. Time-lag-induced discrepancy between internal SI position and that predicted from the external signal (external prediction error) was also calculated. Mean ± standard deviation time lag, over all scans and patients, was 0.10 ± 0.07 s (range 0.01-0.36 s). External signal lagged the internal in 17/18 scans. Change in time lag between pre- and post-treatment CBCT was 0.06 ± 0.07 s (range 0.01-0.22 s), corresponding to 3.1% ± 3.7% (range 0.6%-10.8%) of gate width (range 1.6-3.1 s). In only one patient, change in time lag exceeded 10% of the gate width. External prediction error over all scans of all patients varied from 0.1 ± 0.1 to 1.6 ± 0.4 mm. Time lag between internal motion along SI and external signals is small compared to the treatment gate width of abdominal patients examined in this study. Change in time lag within a treatment session, inferred from pre- to post-treatment measurements is also small, suggesting that a single measurement of time lag at the session start is adequate. These findings require confirmation in a larger number of patients.

  6. Technical Note: Intrafractional changes in time lag relationship between anterior–posterior external and superior–inferior internal motion signals in abdominal tumor sites

    PubMed Central

    Regmi, Rajesh; Lovelock, D. Michael; Zhang, Pengpeng; Pham, Hai; Xiong, Jianping; Yorke, Ellen D.; Goodman, Karyn A.; Wu, Abraham J.; Mageras, Gig S.

    2015-01-01

    Purpose: To investigate constancy, within a treatment session, of the time lag relationship between implanted markers in abdominal tumors and an external motion surrogate. Methods: Six gastroesophageal junction and three pancreatic cancer patients (IRB-approved protocol) received two cone-beam CTs (CBCT), one before and one after treatment. Time between scans was less than 30 min. Each patient had at least one implanted fiducial marker near the tumor. In all scans, abdominal displacement (Varian RPM) was recorded as the external motion signal. Purpose-built software tracked fiducials, representing internal signal, in CBCT projection images. Time lag between superior–inferior (SI) internal and anterior–posterior external signals was found by maximizing the correlation coefficient in each breathing cycle and averaging over all cycles. Time-lag-induced discrepancy between internal SI position and that predicted from the external signal (external prediction error) was also calculated. Results: Mean ± standard deviation time lag, over all scans and patients, was 0.10 ± 0.07 s (range 0.01–0.36 s). External signal lagged the internal in 17/18 scans. Change in time lag between pre- and post-treatment CBCT was 0.06 ± 0.07 s (range 0.01–0.22 s), corresponding to 3.1% ± 3.7% (range 0.6%–10.8%) of gate width (range 1.6–3.1 s). In only one patient, change in time lag exceeded 10% of the gate width. External prediction error over all scans of all patients varied from 0.1 ± 0.1 to 1.6 ± 0.4 mm. Conclusions: Time lag between internal motion along SI and external signals is small compared to the treatment gate width of abdominal patients examined in this study. Change in time lag within a treatment session, inferred from pre- to post-treatment measurements is also small, suggesting that a single measurement of time lag at the session start is adequate. These findings require confirmation in a larger number of patients. PMID:26127033

  7. Physical and structural changes induced by high pressure on corn starch, rice flour and waxy rice flour.

    PubMed

    Cappa, Carola; Lucisano, Mara; Barbosa-Cánovas, Gustavo V; Mariotti, Manuela

    2016-07-01

    The impact of high pressure (HP) processing on corn starch, rice flour and waxy rice flour was investigated as a function of pressure level (400MPa; 600MPa), pressure holding time (5min; 10min), and temperature (20°C; 40°C). Samples were pre-conditioned (final moisture level: 40g/100g) before HP treatments. Both the HP treated and the untreated raw materials were evaluated for pasting properties and solvent retention capacity, and investigated by differential scanning calorimetry, X-ray diffractometry and environmental scanning electron microscopy. Different pasting behaviors and solvent retention capacities were evidenced according to the applied pressure. Corn starch presented a slower gelatinization trend when treated at 600MPa. Corn starch and rice flour treated at 600MPa showed a higher retention capacity of carbonate and lactic acid solvents, respectively. Differential scanning calorimetry and environmental scanning electron microscopy investigations highlighted that HP affected the starch structure of rice flour and corn starch. Few variations were evidenced in waxy rice flour. These results can assist in advancing the HP processing knowledge, as the possibility to successfully process raw samples in a very high sample-to-water concentration level was evidenced. This work investigates the effect of high pressure as a potential technique to modify the processing characteristics of starchy materials without using high temperature. In this case the starches were processed in the powder form - and not as a slurry as in previously reported studies - showing the flexibility of the HP treatment. The relevance for industrial application is the possibility to change the structure of flour starches, and thus modifying the processability of the mentioned products. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Total enbloc spondylectomy for metastatic high grade spinal tumors: Early results

    PubMed Central

    Patil, Sanganagouda S; Nene, Abhay M

    2016-01-01

    Background: High grade metastatic spinal tumors are most common and are invasive. These patients can succumb to disease progression if not treated timely. Although considered as invasive and morbid, total enbloc spondylectomy (TES) in selected cases has better survival rates. The authors describe the results of TES for high grade metastatic spinal tumors. Materials and Methods: Five patients (four females and one male) underwent TES for solitary metastatic vertebral lesion between November 2012 and January 2014. These patients presented to us with spinal instability, unrelenting severe spinal pain and/or with severe progressive radiculopathy. Average age was 46.2 years (range 39–62 years). After complete investigations, computed tomography scan, magnetic resonance imaging scan and positron emission tomography (PET) scan, it was confirmed that these patients had high grade solitary vertebral metastatic tumor. Results: Average duration of followup was 18 months (range 16–20 months). The average preoperative visual analog scale score of 9.4 (range 9–10) improved to 2 (range 1–4) at last followup. Average blood loss was 1440 mL (range 1000–2000 mL). Average duration of surgery was 198 min (range 180–240 min). Significant pain relief was noticed in each patient in the immediate postoperative period and during followups. These patients attained complete functional activities of daily living with in a month. The imaging showed implants in situ, no recurrence of tumor, and no activity on PET scan at the final followup. Conclusion: The present series shows favorable short term results of TES for solitary, metastatic, high grade vertebral body tumors by a team approach. PMID:27512215

  9. High resolution light-sheet based high-throughput imaging cytometry system enables visualization of intra-cellular organelles

    NASA Astrophysics Data System (ADS)

    Regmi, Raju; Mohan, Kavya; Mondal, Partha Pratim

    2014-09-01

    Visualization of intracellular organelles is achieved using a newly developed high throughput imaging cytometry system. This system interrogates the microfluidic channel using a sheet of light rather than the existing point-based scanning techniques. The advantages of the developed system are many, including, single-shot scanning of specimens flowing through the microfluidic channel at flow rate ranging from micro- to nano- lit./min. Moreover, this opens-up in-vivo imaging of sub-cellular structures and simultaneous cell counting in an imaging cytometry system. We recorded a maximum count of 2400 cells/min at a flow-rate of 700 nl/min, and simultaneous visualization of fluorescently-labeled mitochondrial network in HeLa cells during flow. The developed imaging cytometry system may find immediate application in biotechnology, fluorescence microscopy and nano-medicine.

  10. In vitro antibacterial action of Tetraclean, MTAD and five experimental irrigation solutions.

    PubMed

    Pappen, F G; Shen, Y; Qian, W; Leonardo, M R; Giardino, L; Haapasalo, M

    2010-06-01

    To investigate the antibacterial effect of Tetraclean, MTAD and five experimental irrigants using both direct exposure test with planktonic cultures and mixed-species in vitro biofilm model. Tetraclean, MTAD and five experimental solutions that were modifications of existing formulae including MTAD + 0.01% cetrimide (CTR), MTAD + 0.1% CTR, MTAC-1 (Tween 80 replaced by 0.01% CTR in MTAD), MTAC-2 (Tween 80 replaced by 0.1% CTR) and MTAD-D (MTAD without the Tween 80 and no CTR added) were used as disinfectants in the experiments. In the direct exposure test, a suspension of Enterococcus faecalis was mixed with each of the solutions. After 0.5, 1, 3 and 10 min, an inactivator was added and the number of surviving bacteria was calculated. A mixed-species biofilm from subgingival plaque bacteria was grown in brain heart infusion broth in anaerobic conditions on synthetic hydroxyapatite discs. Two-week-old biofilms were exposed to the solutions for 0.5, 1 and 3 min. The samples were observed by confocal laser scanning microscopy after bacterial viability staining. The scans were quantitatively analysed, and the volume of killed cells of all cells was calculated for each medicament. Tetraclean and MTAC-2 (0.1% CTR) killed planktonic E. faecalis in <30 s. Complete killing of bacteria required 1 min by MTAC-1, 3 min by MTAD + 0.1% CTR and 10 min by MTAD, MTAD-D and MTAD + 0.01% CTR. In the biofilm test, there were significant differences in microbial killing between the different solutions and times of exposure (P < 0.005). MTAC-2 showed the best performance, killing 71% of the biofilm bacteria in 3 min, followed by MTAC-1 and Tetraclean. MTAD and the three MTAD modifications demonstrated the lowest antibacterial activity. Tetraclean was more effective than MTAD against E. faecalis in planktonic culture and in mixed-species in vitro biofilm. CTR improved the antimicrobial properties of the solutions, whereas Tween 80 seemed to have a neutral or negative impact on their antimicrobial effectiveness.

  11. Characterization of Soft Contact Lens Fitting Using Ultra-Long Scan Depth Optical Coherence Tomography

    PubMed Central

    Li, Ming; Lu, Fan

    2017-01-01

    Objectives To evaluate the centration and movement of soft contact lenses and to verify the repeatability of two repeated measurements of the lens centration and movement using ultra-long scan depth optical coherence tomography (UL-OCT). Methods A 1-day Acuvue® Define™ lens was tested on both eyes of 10 subjects (5 males and 5 females; mean age, 31.6 years). The centration and blink-induced movement of the contact lens were measured using UL-OCT at 5 min and 30 min after insertion. The measurements were repeated once at each checkpoint. Results Good repeatability was found in the lens centration and movement between the two repeated measurements at either checkpoint. The values of the lens movement were 0.457 ± 0.248 mm and 0.402 ± 0.229 mm at 5 min and decreased to 0.197 ± 0.065 mm and 0.211 ± 0.110 mm at 30 min after insertion for the right and left eyes, respectively (P < 0.05). Conclusions The custom-built UL-OCT presented good repeatability of centration and movement in Define lenses at 5 min and 30 min after insertion. Most of the lenses were centered temporal and inferior to the cornea during the first 30 min wearing period. Compared with 5 min after insertion, the lens was centered better and exhibited less movement at 30 min. PMID:28751981

  12. Microfluidic volumetric flow determination using optical coherence tomography speckle: An autocorrelation approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Pretto, Lucas R., E-mail: lucas.de.pretto@usp.br; Nogueira, Gesse E. C.; Freitas, Anderson Z.

    2016-04-28

    Functional modalities of Optical Coherence Tomography (OCT) based on speckle analysis are emerging in the literature. We propose a simple approach to the autocorrelation of OCT signal to enable volumetric flow rate differentiation, based on decorrelation time. Our results show that this technique could distinguish flows separated by 3 μl/min, limited by the acquisition speed of the system. We further perform a B-scan of gradient flow inside a microchannel, enabling the visualization of the drag effect on the walls.

  13. Empty calories and phantom fullness: a randomized trial studying the relative effects of energy density and viscosity on gastric emptying determined by MRI and satiety.

    PubMed

    Camps, Guido; Mars, Monica; de Graaf, Cees; Smeets, Paul Am

    2016-07-01

    Stomach fullness is a determinant of satiety. Although both the viscosity and energy content have been shown to delay gastric emptying, their relative importance is not well understood. We compared the relative effects of and interactions between the viscosity and energy density on gastric emptying and perceived satiety. A total of 15 healthy men [mean ± SD age: 22.6 ± 2.4 y; body mass index (in kg/m(2)): 22.6 ± 1.8] participated in an experiment with a randomized 2 × 2 crossover design. Participants received dairy-based shakes (500 mL; 50% carbohydrate, 20% protein, and 30% fat) that differed in viscosity (thin and thick) and energy density [100 kcal (corresponding to 0.2 kcal/mL) compared with 500 kcal (corresponding to 1 kcal/mL)]. After ingestion, participants entered an MRI scanner where abdominal scans and oral appetite ratings on a 100-point scale were obtained every 10 min until 90 min after ingestion. From the scans, gastric content volumes were determined. Overall, the gastric emptying half-time (GE t50) was 54.7 ± 3.8 min. The thin 100-kcal shake had the lowest GE t50 of 26.5 ± 3.0 min, followed by the thick 100-kcal shake with a GE t50 of 41 ± 3.9 min and the thin 500-kcal shake with a GE t50 of 69.5 ± 5.9 min, and the thick 500-kcal shake had the highest GE t50 of 81.9 ± 8.3 min. With respect to appetite, the thick 100-kcal shake led to higher fullness (58 points at 40 min) than the thin 500-kcal shake (48 points at 40 min). Our results show that increasing the viscosity is less effective than increasing the energy density in slowing gastric emptying. However, the viscosity is more important to increase the perceived fullness. These results underscore the lack of the satiating efficiency of empty calories in quickly ingested drinks such as sodas. The increase in perceived fullness that is due solely to the increased viscosity, which is a phenomenon that we refer to as phantom fullness, may be useful in lowering energy intake. This trial was registered at www.trialregister.nl as NTR4573. © 2016 American Society for Nutrition.

  14. High-Precision Pinpointing of Luminescent Targets in Encoder-Assisted Scanning Microscopy Allowing High-Speed Quantitative Analysis.

    PubMed

    Zheng, Xianlin; Lu, Yiqing; Zhao, Jiangbo; Zhang, Yuhai; Ren, Wei; Liu, Deming; Lu, Jie; Piper, James A; Leif, Robert C; Liu, Xiaogang; Jin, Dayong

    2016-01-19

    Compared with routine microscopy imaging of a few analytes at a time, rapid scanning through the whole sample area of a microscope slide to locate every single target object offers many advantages in terms of simplicity, speed, throughput, and potential for robust quantitative analysis. Existing techniques that accommodate solid-phase samples incorporating individual micrometer-sized targets generally rely on digital microscopy and image analysis, with intrinsically low throughput and reliability. Here, we report an advanced on-the-fly stage scanning method to achieve high-precision target location across the whole slide. By integrating X- and Y-axis linear encoders to a motorized stage as the virtual "grids" that provide real-time positional references, we demonstrate an orthogonal scanning automated microscopy (OSAM) technique which can search a coverslip area of 50 × 24 mm(2) in just 5.3 min and locate individual 15 μm lanthanide luminescent microspheres with standard deviations of 1.38 and 1.75 μm in X and Y directions. Alongside implementation of an autofocus unit that compensates the tilt of a slide in the Z-axis in real time, we increase the luminescence detection efficiency by 35% with an improved coefficient of variation. We demonstrate the capability of advanced OSAM for robust quantification of luminescence intensities and lifetimes for a variety of micrometer-scale luminescent targets, specifically single down-shifting and upconversion microspheres, crystalline microplates, and color-barcoded microrods, as well as quantitative suspension array assays of biotinylated-DNA functionalized upconversion nanoparticles.

  15. A new spherical scanning system for infrared reflectography of paintings

    NASA Astrophysics Data System (ADS)

    Gargano, M.; Cavaliere, F.; Viganò, D.; Galli, A.; Ludwig, N.

    2017-03-01

    Infrared reflectography is an imaging technique used to visualize the underdrawings of ancient paintings; it relies on the fact that most pigment layers are quite transparent to infrared radiation in the spectral band between 0.8 μm and 2.5 μm. InGaAs sensor cameras are nowadays the most used devices to visualize the underdrawings but due to the small size of the detectors, these cameras are usually mounted on scanning systems to record high resolution reflectograms. This work describes a portable scanning system prototype based on a peculiar spherical scanning system built through a light weight and low cost motorized head. The motorized head was built with the purpose of allowing the refocusing adjustment needed to compensate the variable camera-painting distance during the rotation of the camera. The prototype has been tested first in laboratory and then in-situ for the Giotto panel "God the Father with Angels" with a 256 pixel per inch resolution. The system performance is comparable with that of other reflectographic devices with the advantage of extending the scanned area up to 1 m × 1 m, with a 40 min scanning time. The present configuration can be easily modified to increase the resolution up to 560 pixels per inch or to extend the scanned area up to 2 m × 2 m.

  16. Surgery for patients with primary hyperparathyroidism and negative sestamibi scintigraphy--a feasibility study.

    PubMed

    Thier, Mark; Nordenström, Erik; Bergenfelz, Anders; Westerdahl, Johan

    2009-09-01

    We report the surgical treatment of a consecutive series of scan negative patients with the intention of unilateral parathyroid exploration with the aid of intraoperative quick PTH (qPTH). The study included 35 consecutive sestamibi scan negative patients (27 women, eight men) with sporadic pHPT subjected to first time surgery. Median age was 70 years and median preoperative calcium level 2.8 mmol/L. Thirty-three patients had a histological diagnosis of a parathyroid adenoma (median weight 0.48 g [range 0.12 g-2.5 g]). Nineteen patients were explored bilaterally and 16 patients (46%) were operated unilaterally. The median operation time was 40 min in the unilateral group and 95 min in the bilateral group (p < 0.001). Three patients were treated for postoperative hypocalcemia after bilateral exploration versus none in the unilateral group (p = 0.23). With a minimum of 12 months of follow-up, 33 patients (94.3%) were cured. One case of recurrent HPT presented after bilateral exploration with visualization of four glands. One case of persistent HPT was observed after unilateral exploration. qPTH was predictive of operative failure in both patients. Forty-six percent of the patients in our study could be operated unilaterally with a total cure rate of 94%. Patients in the unilateral group had a significant shorter operation time and a lower incidence of postoperative hypocalcemia. In conclusion our investigation shows that limited parathyroid exploration can safely be performed on patients with negative sestamibi scintigraphy by the aid of qPTH.

  17. Characterization of a multi-axis ion chamber array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simon, Thomas A.; Kozelka, Jakub; Simon, William E.

    Purpose: The aim of this work was to characterize a multi-axis ion chamber array (IC PROFILER; Sun Nuclear Corporation, Melbourne, FL USA) that has the potential to simplify the acquisition of LINAC beam data. Methods: The IC PROFILER (or panel) measurement response was characterized with respect to radiation beam properties, including dose, dose per pulse, pulse rate frequency (PRF), and energy. Panel properties were also studied, including detector-calibration stability, power-on time, backscatter dependence, and the panel's agreement with water tank measurements [profiles, fractional depth dose (FDD), and output factors]. Results: The panel's relative deviation was typically within ({+-}) 1% ofmore » an independent (or nominal) response for all properties that were tested. Notable results were (a) a detectable relative field shape change of {approx}1% with linear accelerator PRF changes; (b) a large range in backscatter thickness had a minimal effect on the measured dose distribution (typically less than 1%); (c) the error spread in profile comparison between the panel and scanning water tank (Blue Phantom, CC13; IBA Schwarzenbruck, DE) was approximately ({+-}) 0.75%. Conclusions: The ability of the panel to accurately reproduce water tank profiles, FDDs, and output factors is an indication of its abilities as a dosimetry system. The benefits of using the panel versus a scanning water tank are less setup time and less error susceptibility. The same measurements (including device setup and breakdown) for both systems took 180 min with the water tank versus 30 min with the panel. The time-savings increase as the measurement load is increased.« less

  18. Monitoring proton radiation therapy with in-room PET imaging

    NASA Astrophysics Data System (ADS)

    Zhu, Xuping; España, Samuel; Daartz, Juliane; Liebsch, Norbert; Ouyang, Jinsong; Paganetti, Harald; Bortfeld, Thomas R.; El Fakhri, Georges

    2011-07-01

    We used a mobile positron emission tomography (PET) scanner positioned within the proton therapy treatment room to study the feasibility of proton range verification with an in-room, stand-alone PET system, and compared with off-line equivalent studies. Two subjects with adenoid cystic carcinoma were enrolled into a pilot study in which in-room PET scans were acquired in list-mode after a routine fractionated treatment session. The list-mode PET data were reconstructed with different time schemes to generate in-room short, in-room long and off-line equivalent (by skipping coincidences from the first 15 min during the list-mode reconstruction) PET images for comparison in activity distribution patterns. A phantom study was followed to evaluate the accuracy of range verification for different reconstruction time schemes quantitatively. The in-room PET has a higher sensitivity compared to the off-line modality so that the PET acquisition time can be greatly reduced from 30 to <5 min. Features in deep-site, soft-tissue regions were better retained with in-room short PET acquisitions because of the collection of 15O component and lower biological washout. For soft tissue-equivalent material, the distal fall-off edge of an in-room short acquisition is deeper compared to an off-line equivalent scan, indicating a better coverage of the high-dose end of the beam. In-room PET is a promising low cost, high sensitivity modality for the in vivo verification of proton therapy. Better accuracy in Monte Carlo predictions, especially for biological decay modeling, is necessary.

  19. Spatiotemporal image correlation spectroscopy (STICS) theory, verification, and application to protein velocity mapping in living CHO cells.

    PubMed

    Hebert, Benedict; Costantino, Santiago; Wiseman, Paul W

    2005-05-01

    We introduce a new extension of image correlation spectroscopy (ICS) and image cross-correlation spectroscopy (ICCS) that relies on complete analysis of both the temporal and spatial correlation lags for intensity fluctuations from a laser-scanning microscopy image series. This new approach allows measurement of both diffusion coefficients and velocity vectors (magnitude and direction) for fluorescently labeled membrane proteins in living cells through monitoring of the time evolution of the full space-time correlation function. By using filtering in Fourier space to remove frequencies associated with immobile components, we are able to measure the protein transport even in the presence of a large fraction (>90%) of immobile species. We present the background theory, computer simulations, and analysis of measurements on fluorescent microspheres to demonstrate proof of principle, capabilities, and limitations of the method. We demonstrate mapping of flow vectors for mixed samples containing fluorescent microspheres with different emission wavelengths using space time image cross-correlation. We also present results from two-photon laser-scanning microscopy studies of alpha-actinin/enhanced green fluorescent protein fusion constructs at the basal membrane of living CHO cells. Using space-time image correlation spectroscopy (STICS), we are able to measure protein fluxes with magnitudes of mum/min from retracting lamellar regions and protrusions for adherent cells. We also demonstrate the measurement of correlated directed flows (magnitudes of mum/min) and diffusion of interacting alpha5 integrin/enhanced cyan fluorescent protein and alpha-actinin/enhanced yellow fluorescent protein within living CHO cells. The STICS method permits us to generate complete transport maps of proteins within subregions of the basal membrane even if the protein concentration is too high to perform single particle tracking measurements.

  20. Evaluation of three-dimensional computed tomography processing for deep inferior epigastric perforator flap breast reconstruction.

    PubMed

    Teoh, Raymond; Johnson, Raleigh F; Nishino, Thomas K; Ethridge, Richard T

    2007-01-01

    The deep inferior epigastric perforator flap procedure has become a popular alternative for women who require breast reconstruction. One of the difficulties with this procedure is identifying perforator arteries large enough to ensure that the harvested tissue is well vascularized. Current techniques involve imaging the perforator arteries with computed tomography (CT) to produce a grid mapping the locations of the perforator arteries relative to the umbilicus. To compare the time it takes to produce a map of the perforators using either two-dimensional (2D) or three-dimensional (3D) CT, and to see whether there is a benefit in using a 3D model. Patient CT abdomen and pelvis scans were acquired from a GE 64-slice scanner. CT image processing was performed with the GE 3D Advantage Workstation v4.2 software. Maps of the perforators were generated both as 2D and 3D representations. Perforators within a region 5 cm rostral and 7 cm caudal to the umbilicus were measured and the times to perform these measurements using both 2D and 3D images were recorded by a stopwatch. Although the 3D method took longer than the 2D method (mean [+/- SD] time 1:51+/-0:35 min versus 1:08+/-0:16 min per perforator artery, respectively), producing a 3D image provides much more information than the 2D images alone. Additionally, an actual-sized 3D image can be printed out, removing the need to make measurements and producing a grid. Although it took less time to create a grid of the perforators using 2D axial CT scans, the 3D reconstruction of the abdomen allows the plastic surgeons to better visualize the patient's anatomy and has definite clinical utility.

  1. Scanning Electron Microscopy and Energy-Dispersive X-Ray Microanalysis of Set CEM Cement after Application of Different Bleaching Agents.

    PubMed

    Samiei, Mohammad; Janani, Maryam; Vahdati, Amin; Alemzadeh, Yalda; Bahari, Mahmoud

    2017-01-01

    The present study evaluated the element distribution in completely set calcium-enriched mixture (CEM) cement after application of 35% carbamide peroxide, 40% hydrogen peroxide and sodium perborate as commercial bleaching agents using an energy-dispersive x-ray microanalysis (EDX) system. The surface structure was also observed using the scanning electron microscope (SEM). Twenty completely set CEM cement samples, measuring 4×4 mm 2 , were prepared in the present in vitro study and randomly divided into 4 groups based on the preparation technique as follows: the control group; 35% carbamide peroxide group in contact for 30-60 min for 4 times; 40% hydrogen peroxide group with contact time of 15-20 min for 3 times; and sodium perborate group, where the powder and liquid were mixed and placed on CEM cement surface 4 times. Data were analyzed at a significance level of 0.05 through the one Way ANOVA and Tukey's post hoc tests. EDX showed similar element distribution of oxygen, sodium, calcium and carbon in CEM cement with the use of carbamide peroxide and hydroxide peroxide; however, the distribution of silicon was different ( P <0.05). In addition, these bleaching agents resulted in significantly higher levels of oxygen and carbon ( P <0.05) and a lower level of calcium ( P <0.05) compared to the control group. SEM of the control group showed plate-like and globular structure. Sodium perborate was similar to control group due to its weak oxidizing properties. Globular structures and numerous woodpecker holes were observed on the even surface on the carbamide peroxide group. The mean elemental distribution of completely set CEM cement was different when exposed to sodium perborate, carbamide peroxide and hydrogen peroxide.

  2. Glioblastoma Segmentation: Comparison of Three Different Software Packages.

    PubMed

    Fyllingen, Even Hovig; Stensjøen, Anne Line; Berntsen, Erik Magnus; Solheim, Ole; Reinertsen, Ingerid

    2016-01-01

    To facilitate a more widespread use of volumetric tumor segmentation in clinical studies, there is an urgent need for reliable, user-friendly segmentation software. The aim of this study was therefore to compare three different software packages for semi-automatic brain tumor segmentation of glioblastoma; namely BrainVoyagerTM QX, ITK-Snap and 3D Slicer, and to make data available for future reference. Pre-operative, contrast enhanced T1-weighted 1.5 or 3 Tesla Magnetic Resonance Imaging (MRI) scans were obtained in 20 consecutive patients who underwent surgery for glioblastoma. MRI scans were segmented twice in each software package by two investigators. Intra-rater, inter-rater and between-software agreement was compared by using differences of means with 95% limits of agreement (LoA), Dice's similarity coefficients (DSC) and Hausdorff distance (HD). Time expenditure of segmentations was measured using a stopwatch. Eighteen tumors were included in the analyses. Inter-rater agreement was highest for BrainVoyager with difference of means of 0.19 mL and 95% LoA from -2.42 mL to 2.81 mL. Between-software agreement and 95% LoA were very similar for the different software packages. Intra-rater, inter-rater and between-software DSC were ≥ 0.93 in all analyses. Time expenditure was approximately 41 min per segmentation in BrainVoyager, and 18 min per segmentation in both 3D Slicer and ITK-Snap. Our main findings were that there is a high agreement within and between the software packages in terms of small intra-rater, inter-rater and between-software differences of means and high Dice's similarity coefficients. Time expenditure was highest for BrainVoyager, but all software packages were relatively time-consuming, which may limit usability in an everyday clinical setting.

  3. Magnetic ring anastomosis of suprahepatic vena cava: novel technique for liver transplantation in rat.

    PubMed

    Shi, Yuan; Zhang, Wei; Deng, Yong-lin; Zhang, Ya-min; Zhang, Quan-sheng; Zhang, Wei-ye; Zheng, Hong; Pan, Cheng; Shen, Zhong-Yang

    2015-01-01

    To improve the technique of suprahepatic vena cava (SHVC) reconstruction in rat OLT, novel magnetic rings were designed and manufactured to facilitate reconstruction of SHVC and shorten the anhepatic time. One-hundred and twenty adult male Wistar rats were randomly divided into two groups: rings group (n = 30), using magnetic rings for SHVC reconstruction; suture group (n = 30), 7/0 prolene suture was used for SHVC running anastomosis as control. Cuff techniques were used for portal vein and infrahepatic vena cava reconstruction as Kamada and Calne described. The bile duct was reconnected with a stent. The hepatic re-arterialization was omitted. In the rings group, the SHVC reconstruction took 0.91 ± 0.24 (mean ± SD) min; the anhepatic phase and the recipient operation time were 5.63 ± 0.65 min and 36.02 ± 8.02 min, respectively. In suture group, the anastomotic time of SHVC was 10.40 ± 2.11 min; the anhepatic phase and the recipient operation time were 17.76 ± 2.51 and 49.38 ± 12.06 min, respectively, and there was statistically significant difference between the two groups. The ALT levels reached peak at 24 h post-OLT (186.2 ± 32.5 IU/l) and restored to normal level at 96 h gradually. In the rings group, 29 of 30 rats survived at day 7 and 28 of 30 rats survived at day 30. In contrast, only 25 of 30 recipients in suture group remained alive at day 7 and 22 of 30 remained alive at day 30 (P < 0.05). Better anastomotic healing was founded in rings group by pathology and scanning electron microscope. The magnetic rings technique provides a novel, simple method for SHVC reconstruction of OLT in rat. It significantly shortens anhepatic phase, while the success rate of the operation is satisfactory. © 2014 Steunstichting ESOT.

  4. Estimation of immunization providers' activities cost, medication cost, and immunization dose errors cost in Iraq.

    PubMed

    Al-lela, Omer Qutaiba B; Bahari, Mohd Baidi; Al-abbassi, Mustafa G; Salih, Muhannad R M; Basher, Amena Y

    2012-06-06

    The immunization status of children is improved by interventions that increase community demand for compulsory and non-compulsory vaccines, one of the most important interventions related to immunization providers. The aim of this study is to evaluate the activities of immunization providers in terms of activities time and cost, to calculate the immunization doses cost, and to determine the immunization dose errors cost. Time-motion and cost analysis study design was used. Five public health clinics in Mosul-Iraq participated in the study. Fifty (50) vaccine doses were required to estimate activities time and cost. Micro-costing method was used; time and cost data were collected for each immunization-related activity performed by the clinic staff. A stopwatch was used to measure the duration of activity interactions between the parents and clinic staff. The immunization service cost was calculated by multiplying the average salary/min by activity time per minute. 528 immunization cards of Iraqi children were scanned to determine the number and the cost of immunization doses errors (extraimmunization doses and invalid doses). The average time for child registration was 6.7 min per each immunization dose, and the physician spent more than 10 min per dose. Nurses needed more than 5 min to complete child vaccination. The total cost of immunization activities was 1.67 US$ per each immunization dose. Measles vaccine (fifth dose) has a lower price (0.42 US$) than all other immunization doses. The cost of a total of 288 invalid doses was 744.55 US$ and the cost of a total of 195 extra immunization doses was 503.85 US$. The time spent on physicians' activities was longer than that spent on registrars' and nurses' activities. Physician total cost was higher than registrar cost and nurse cost. The total immunization cost will increase by about 13.3% owing to dose errors. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Destructive and non-destructive evaluation of cu/cu diffusion bonding with interlayer aluminum

    NASA Astrophysics Data System (ADS)

    Santosh Kumar, A.; Mohan, T.; Kumar, S. Suresh; Ravisankar, B.

    2018-03-01

    The current study is established an inspection procedure for assessing quality of diffusion bonded joints using destructive and non-destructive method. Diffusion bonding of commercially pure copper with aluminium interlayer was carried out uniaxial load at 15MPa for different temperatures under holding time 60 min in vacuum atmosphere. The bond qualities were determined by destructive and non-destructive testing method (ultrasonic C- scan). The bond interface and bonded samples were analysed using optical and scanning electron microscopy (SEM). The element composition of the fractured and bonded area is determined using the Energy Dispersive Spectrometry (EDS). The bond quality obtained by both testing methods and its parameters are correlated. The optimized bonding parameter for best bonding characteristics for copper diffusion bonding with aluminum interlayer is reported.

  6. Metal-based anode for high performance bioelectrochemical systems through photo-electrochemical interaction

    NASA Astrophysics Data System (ADS)

    Liang, Yuxiang; Feng, Huajun; Shen, Dongsheng; Long, Yuyang; Li, Na; Zhou, Yuyang; Ying, Xianbin; Gu, Yuan; Wang, Yanfeng

    2016-08-01

    This paper introduces a novel composite anode that uses light to enhance current generation and accelerate biofilm formation in bioelectrochemical systems. The composite anode is composed of 316L stainless steel substrate and a nanostructured α-Fe2O3 photocatalyst (PSS). The electrode properties, current generation, and biofilm properties of the anode are investigated. In terms of photocurrent, the optimal deposition and heat-treatment times are found to be 30 min and 2 min, respectively, which result in a maximum photocurrent of 0.6 A m-2. The start-up time of the PSS is 1.2 days and the maximum current density is 2.8 A m-2, twice and 25 times that of unmodified anode, respectively. The current density of the PSS remains stable during 20 days of illumination. Confocal laser scanning microscope images show that the PSS could benefit biofilm formation, while electrochemical impedance spectroscopy indicates that the PSS reduce the charge-transfer resistance of the anode. Our findings show that photo-electrochemical interaction is a promising way to enhance the biocompatibility of metal anodes for bioelectrochemical systems.

  7. Evaluation of ischaemia in obese patients: feasibility and accuracy of a low-dose protocol with a cadmium-zinc telluride camera.

    PubMed

    Gimelli, Alessia; Bottai, Matteo; Giorgetti, Assuero; Genovesi, Dario; Filidei, Elena; Marzullo, Paolo

    2012-08-01

    Obesity is a significant and independent risk factor for cardiovascular disease, and assessing ischaemia in obese patients is clinically important but sometimes difficult because of imaging artefacts. The aim of this study was to evaluate the feasibility and diagnostic accuracy of stress/rest imaging with a cadmium-zinc telluride (CZT) camera using a low-dose protocol in a series of consecutive obese patients referred for the evaluation of coronary artery disease. We considered 148 consecutive obese patients (mean BMI 39 ± 7 kg/m(2)) with known or suspected coronary artery disease referred to our laboratory for stress/rest myocardial perfusion imaging. A subgroup of 103 of the 148 patients underwent invasive coronary angiography for clinical reasons. All patients underwent a single-day stress/rest low-dose ultrafast protocol. Patients were injected with (99m)Tc-tetrofosmin at a dose in the range 185-222 MBq during bicycle exercise or dipyridamole stress, and underwent the first scan with an acquisition time of 7 min starting 15 min after the end of the stress. The rest scan with an acquisition time of 6 min was started from 30 to 45 min after (99m)Tc-tetrofosmin injection at a dose in the range 370-444 MBq. Images were visually inspected, and the summed stress score (SSS) and summed rest score (SRS) were obtained. Image quality was graded very good or excellent in all patients. Of the 103 patients who underwent coronary angiography, 12 (12 %), 26 (25 %) and 56 (54 %) showed one-, two- and three-vessel disease, and 9 showed normal coronary vessels. In the 103 patients submitted to coronary angiography, the mean SSS and SRS were 7 ± 6 and 2 ± 3, respectively. Semiquantitative regional and global SSS was a good discriminant of coronary artery disease and the area under the overall ROC curve was 0.848 (95 % CI 0.723-0.975). In obese patients, a single-day stress/rest low-dose ultrafast protocol with a CZT camera is clinically feasible and provides high image quality.

  8. High-efficiency treatment of PTA wastewater using a biogas jet assisted anaerobic fluidized bed reactor.

    PubMed

    Zhang, Wei; Feng, Yangyang; Chen, Yingwen; Li, Peiwen; Zhu, Shemin; Shen, Shubao

    2018-02-05

    In this paper, a new type of biogas jet assisted anaerobic fluidized bed reactor loaded with a polypropylene carrier has been proposed. There was a clear improvement in the fluidized state due to the biogas assisted input when the gas/water ratio was set at 1:3 with a suitable carrier loading of 60%. When the circulating water flow is 30 L/min assisted with biogas 10 L/min, the mixing time shortens from 26 to 18 s. The performance of anaerobic biodegradation on wastewater treatment was improved largely. The chemical oxygen demand (COD) and terepthallic acid removal efficiencies were at 85.4% and 84%, respectively, at hydraulic retention time of 20 h, even when the influent COD concentration was as high as 4224 mg/L. In addition, plenty of microorganisms, attached to the carriers and assumed to be the reason behind the organic biodegradation efficiency of the proposed system, were observed using scanning electron microscopy.

  9. Microwave-Assisted Synthesis of Goethite Nanoparticles Used for Removal of Cr(VI) from Aqueous Solution

    PubMed Central

    Kynicky, Jindrich; Adam, Vojtech

    2017-01-01

    The microwave-assisted synthesis of goethite nanoparticles has been studied. The samples were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), thermogravimetric analysis (TGA), differential thermal analysis (DTA) and Brunauer–Emmett–Teller (BET) method. Goethite rod-like nanoparticles have been successfully synthesized in 10 min of microwave treating at 100 °C. Particle size is in the range from 30 to 60 nm in width and from 200 to 350 nm in length. BET analysis indicated that the surface area of the product is 158.31 m2g−1. The feasibility of Cr(VI) removal fromaqueous solution depends on the pH of the solution and contact time. The maximum adsorptionis reached at pH 4.0 and 540 min of contact time. The adsorption kinetics was analyzedby the pseudo-first- and second-order models and the results reveal that the adsorption process obeys the pseudo-second-order model. The adsorption data were fitted well with the Langmuir adsorption isotherm. PMID:28773142

  10. Effective Thermal Inactivation of the Spores of Bacillus cereus Biofilms Using Microwave.

    PubMed

    Park, Hyong Seok; Yang, Jungwoo; Choi, Hee Jung; Kim, Kyoung Heon

    2017-07-28

    Microwave sterilization was performed to inactivate the spores of biofilms of Bacillus cereus involved in foodborne illness. The sterilization conditions, such as the amount of water and the operating temperature and treatment time, were optimized using statistical analysis based on 15 runs of experimental results designed by the Box-Behnken method. Statistical analysis showed that the optimal conditions for the inactivation of B. cereus biofilms were 14 ml of water, 108°C of temperature, and 15 min of treatment time. Interestingly, response surface plots showed that the amount of water is the most important factor for microwave sterilization under the present conditions. Complete inactivation by microwaves was achieved in 5 min, and the inactivation efficiency by microwave was obviously higher than that by conventional steam autoclave. Finally, confocal laser scanning microscopy images showed that the principal effect of microwave treatment was cell membrane disruption. Thus, this study can contribute to the development of a process to control food-associated pathogens.

  11. LPG sensing characteristics of electrospray deposited SnO2 nanoparticles

    NASA Astrophysics Data System (ADS)

    Gürbüz, Mevlüt; Günkaya, Göktuğ; Doğan, Aydın

    2014-11-01

    In this study, SnO2 films were fabricated on conductive substrate such as aluminum and platinum coated alumina using electro-spray deposition (ESD) method for gas sensor applications. Solution flow rate, coating time, substrate-nozzle distance and solid/alcohol ratio were studied to optimize SnO2 film structure. The morphology of the deposited films was characterized by stereo and scanning electron microscopy (SEM). The gas sensing properties of tin oxide films were investigated using liquid petroleum gas (LPG) for various lower explosive limit (LEL). The results obtained from microscopic analyses show that optimum SnO2 films were evaluated at flow rate of 0.05 ml/min, at distance of 6 cm, for 10 min deposition time, for 20 gSnO2/Lethanol ratio and at 7 kV DC electric field. By the results obtained from the gas sensing behavior, the sensitivity of the films was increased with operating temperature. The films showed better sensitivity for 20 LEL LPG concentration at 450 °C operating temperature.

  12. Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cornelis, F.; Takaki, H.; Laskhmanan, M.

    PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the samemore » physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy.« less

  13. Comparison of Stereotactic and Ultrasound-guided Biopsy of Solid Supratentorial Tumor: A Preliminary Report

    PubMed Central

    Satyarthee, Guru Dutta; Chandra, P. Sarat; Sharma, Bhawani S.; Mehta, V. S.

    2017-01-01

    Introduction: The computed tomography (CT) guided stereotactic biopsy (STB) is considered as method of choice for biopsy of intracranial mass lesions. However, it's disadvantages are frame fixation, time requirement for transportation between CT scan suit to the operation theater with added much higher equipment cost in the relatively resource scarred developing country. Ultrasound-guided biopsy (USGB) is relatively simpler, economical, less time consuming, and real-time procedure. Clinical Materials and Methods: Thirty-seven consecutively admitted patients with supratentorial brain tumors, who underwent biopsy of the lesion using CT compatible stereotactic and ultrasound-guided (USGB) procedure formed cohort of the study. Based on location and size of the lesions, the cases were divided into two groups, superficial and deep. Twenty-two patients underwent ultrasound-guided biopsy and 15 with STB. Results: The diagnostic yield of STB was 93% and 91% for ultrasound-guided biopsy. The mean operation time of STB group was 149.00 min and 94 min for USGB, which was statistically significant. Two cases in each group developed hematoma; however, one case in USGB group needed surgical evacuation. The real-time monitoring detected two hematoma intraoperatively, which were further also confirmed on postoperative CT scan head. Conclusions: The ultrasound-guided biopsy procedure (USGB) was simple, relatively shorter time-consuming procedure and equally efficacious and utilizing economical equipment and can act as a safer alternative to CT STB process for biopsy of the intracranial mass lesion. Furthermore, USGB also provided intra-operative real-time monitoring, which provided clue for close monitoring in the postoperative period after completion of biopsy to look for development of fresh hematoma development not only at the biopsy site but also along the biopsy track and adjoining area. Perhaps, a longer period of ultrasonic monitoring following the procedure would be of greater help to detect hematoma formation, which is one of the most common complications of the biopsy procedure. PMID:29114280

  14. The Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kroes, Maarten W., E-mail: Maarten.Kroes@radboudumc.nl; Strijen, Marco J. L. van, E-mail: m.van.strijen@antoniusziekenhuis.nl; Braak, Sicco J., E-mail: sjbraak@gmail.com

    2016-09-15

    PurposeWhen using laser guidance for cone-beam computed tomography (CBCT)-guided needle interventions, planned needle paths are visualized to the operator without the need to switch between entry- and progress-view during needle placement. The current study assesses the effect of laser guidance during CBCT-guided biopsies on fluoroscopy and procedure times.Materials and MethodsProspective data from 15 CBCT-guided biopsies of 8–65 mm thoracic and abdominal lesions assisted by a ceiling-mounted laser guidance technique were compared to retrospective data of 36 performed CBCT-guided biopsies of lesions >20 mm using the freehand technique. Fluoroscopy time, procedure time, and number of CBCT-scans were recorded. All data are presented asmore » median (ranges).ResultsFor biopsies using the freehand technique, more fluoroscopy time was necessary to guide the needle onto the target, 165 s (83–333 s) compared to 87 s (44–190 s) for laser guidance (p < 0.001). Procedure times were shorter for freehand-guided biopsies, 24 min versus 30 min for laser guidance (p < 0.001).ConclusionThe use of laser guidance during CBCT-guided biopsies significantly reduces fluoroscopy time.« less

  15. The Use of Magnetic Resonance Imaging in Axial Spondyloarthritis: Time to Bridge the Gap Between Radiologists and Rheumatologists.

    PubMed

    Bennett, Alexander N; Marzo-Ortega, Helena; Kaur-Papadakis, Daljit; Rehman, Amer

    2017-06-01

    Magnetic resonance imaging (MRI) is involved in the assessment of axial spondyloarthritis (axSpA); however, anecdotal evidence suggests diverse practice among radiologists. The objective of this study was to describe current practice in the use of MRI for assessment of axSpA by UK radiologists. Six hundred ninety-nine UK radiologists were invited to complete an online survey. Availability of MR scanners, familiarity with axSpA disease-specific lesions, and MRI protocols and definitions of positive sacroiliac joint (SIJ) or spinal MRI were assessed. Two-hundred sixty-nine radiologists (38%) from 131/180 (73%) acute UK National Health Service trusts/health boards responded. MRI waiting times < 2 months were reported by 90% of radiologists. Twenty-nine radiologists (11%) used contrast as standard, 256 (91%) used T1 and short-tau inversion recovery, and 172 (64%) also used T2 sequences. Five percent scanned only SIJ, 33% scanned SIJ and lumbar spine, 29% scanned SIJ and thoracolumbar spine, and 30% scanned SIJ and the whole spine. Mean scan time was 34 min. Eighteen percent did not use the subchondral bone marrow edema of the SIJ to help diagnose axSpA and 18% did not use the inflammatory vertebral corner lesions to assist diagnosis. Awareness of axSpA was reported by 75% of radiologists, and awareness of definitions for positive MRI of SIJ and spine by 31% and 25%, respectively. These data highlight the need for better rheumatology-radiology collaboration on the identification of diagnostic axSpA MRI lesions and support the need for a consensus on the most appropriate MRI protocols for the assessment of axSpA.

  16. Feasibility of Using Gluconolactone, Trehalose and Hydroxy-Propyl Gamma Cyclodextrin to Enhance Bendroflumethiazide Dissolution Using Lyophilisation and Physical Mixing Techniques.

    PubMed

    Saleh, Ashraf; McGarry, Kenneth; Chaw, Cheng Shu; Elkordy, Amal Ali

    2018-02-01

    Hydrophobic drugs are facing a major challenge in dissolution rate enhancement and solubility in aqueous solutions; therefore, a variety of methods have been used to improve dissolution rate and/or solubility of bendroflumethiazide as a model hydrophobic drug. In this study, two main methods (physical mixing and lyophilisation) were used with gluconolactone, hydroxyl propyl γ-ccyclodextrin, and trehalose to explore this challenge. Bendroflumethiazide, practically insoluble in water, was mixed with one of the three excipients gluconolactone, hydroxyl propyl γ-cyclodextrin, and trehalose in three different ratios 1:1, 1:2, 1:5. To the best of our knowledge, the dissolution of the drug has not been previously enhanced by using either these methods or any of the used excipients. Samples containing drug and each of the excipients were characterized via dissolution testing, Fourier Transform infra-red spectroscopy, differential scanning calorimetry, and scanning electron microscopy. The used methods showed a significant enhancement in dug dissolution rate; physical mixing significantly, p < 0.05, increased the percentage of the drug released with time; for example, bendroflumethiazide dissolution in distilled water was improved from less than 20% to 99.79% within 90 min for physically mixed drug-cyclodextrin 1:5. The lyophilisation process was enhanced and the drug dissolution rate and the highest drug dissolution was achieved for (drug-gluconolactone 1:1) with 98.98% drug release within 90 min. the physical mixing and freeze drying processes significantly increased the percentage of drug release with time.

  17. High-field open versus short-bore magnetic resonance imaging of the spine: a randomized controlled comparison of image quality.

    PubMed

    Enders, Judith; Rief, Matthias; Zimmermann, Elke; Asbach, Patrick; Diederichs, Gerd; Wetz, Christoph; Siebert, Eberhard; Wagner, Moritz; Hamm, Bernd; Dewey, Marc

    2013-01-01

    The purpose of the present study was to compare the image quality of spinal magnetic resonance (MR) imaging performed on a high-field horizontal open versus a short-bore MR scanner in a randomized controlled study setup. Altogether, 93 (80% women, mean age 53) consecutive patients underwent spine imaging after random assignement to a 1-T horizontal open MR scanner with a vertical magnetic field or a 1.5-T short-bore MR scanner. This patient subset was part of a larger cohort. Image quality was assessed by determining qualitative parameters, signal-to-noise (SNR) and contrast-to-noise ratios (CNR), and quantitative contour sharpness. The image quality parameters were higher for short-bore MR imaging. Regarding all sequences, the relative differences were 39% for the mean overall qualitative image quality, 53% for the mean SNR values, and 34-37% for the quantitative contour sharpness (P<0.0001). The CNR values were also higher for images obtained with the short-bore MR scanner. No sequence was of very poor (nondiagnostic) image quality. Scanning times were significantly longer for examinations performed on the open MR scanner (mean: 32±22 min versus 20±9 min; P<0.0001). In this randomized controlled comparison of spinal MR imaging with an open versus a short-bore scanner, short-bore MR imaging revealed considerably higher image quality with shorter scanning times. ClinicalTrials.gov NCT00715806.

  18. High-Field Open versus Short-Bore Magnetic Resonance Imaging of the Spine: A Randomized Controlled Comparison of Image Quality

    PubMed Central

    Zimmermann, Elke; Asbach, Patrick; Diederichs, Gerd; Wetz, Christoph; Siebert, Eberhard; Wagner, Moritz; Hamm, Bernd; Dewey, Marc

    2013-01-01

    Background The purpose of the present study was to compare the image quality of spinal magnetic resonance (MR) imaging performed on a high-field horizontal open versus a short-bore MR scanner in a randomized controlled study setup. Methods Altogether, 93 (80% women, mean age 53) consecutive patients underwent spine imaging after random assignement to a 1-T horizontal open MR scanner with a vertical magnetic field or a 1.5-T short-bore MR scanner. This patient subset was part of a larger cohort. Image quality was assessed by determining qualitative parameters, signal-to-noise (SNR) and contrast-to-noise ratios (CNR), and quantitative contour sharpness. Results The image quality parameters were higher for short-bore MR imaging. Regarding all sequences, the relative differences were 39% for the mean overall qualitative image quality, 53% for the mean SNR values, and 34–37% for the quantitative contour sharpness (P<0.0001). The CNR values were also higher for images obtained with the short-bore MR scanner. No sequence was of very poor (nondiagnostic) image quality. Scanning times were significantly longer for examinations performed on the open MR scanner (mean: 32±22 min versus 20±9 min; P<0.0001). Conclusions In this randomized controlled comparison of spinal MR imaging with an open versus a short-bore scanner, short-bore MR imaging revealed considerably higher image quality with shorter scanning times. Trial Registration ClinicalTrials.gov NCT00715806 PMID:24391767

  19. The cerebral neurobiology of anxiety, anxiety displacement, and anxiety denial.

    PubMed

    Gottschalk, L A; Fronczek, J; Abel, L; Buchsbaum, M S; Fallon, J H

    2001-01-01

    Previous studies examining the relationship of anxiety scores, derived from the content analysis of speech of normal individuals, have revealed that the anxiety scores occurring in the dreams associated with rapid eye movement (REM) sleep are significantly correlated with localized cerebral glucose metabolic rates assessed by positron emission tomography (PET) scanning. These significant intercorrelations occur in different cerebral areas when the anxiety scores are obtained from mental experiences reported during non-REM sleep or during wakeful silent mentation. The purpose of the present study was to examine the intercorrelations found between anxiety attributed to the self, anxiety-displacement, and anxiety denial measured from computerized content analysis of 5-min verbal reports of subjective thoughts and feelings obtained from wakeful normal subjects and localized cerebral glucose metabolic rates during PET scanning. The subjects were 10 wakeful young males. Their anxiety scores were derived from computerized content analysis of 5-min reports they gave of their subjective thoughts, feelings and fantasies during a 30-min period following an intravenous injection of F D-deoxyglucose (FDG). The subjects were moved 32--45 min after this injection to obtain a PET scan, which records all of the localized cerebral glucose metabolic rates during the 30 min following the FDG injection. Significant intercorrelations of localized cerebral glucose metabolic rates with the scores of self-anxiety, anxiety displacement, and anxiety-denial were found in dissimilar cerebral locations depending on the type of anxiety involved. The significant correlations occurred in brain regions known to be associated with the functions of emotions, cognition, memory, and vision. Specific combinations of cerebral areas, based on glucose metabolic rates, appear to distinguish and be associated with different verbal expressions of anxiety. Replication of this preliminary research will be carried out. Copyright 2001 S. Karger AG, Basel

  20. Automated terrestrial laser scanning with near-real-time change detection - monitoring of the Séchilienne landslide

    NASA Astrophysics Data System (ADS)

    Kromer, Ryan A.; Abellán, Antonio; Hutchinson, D. Jean; Lato, Matt; Chanut, Marie-Aurelie; Dubois, Laurent; Jaboyedoff, Michel

    2017-05-01

    We present an automated terrestrial laser scanning (ATLS) system with automatic near-real-time change detection processing. The ATLS system was tested on the Séchilienne landslide in France for a 6-week period with data collected at 30 min intervals. The purpose of developing the system was to fill the gap of high-temporal-resolution TLS monitoring studies of earth surface processes and to offer a cost-effective, light, portable alternative to ground-based interferometric synthetic aperture radar (GB-InSAR) deformation monitoring. During the study, we detected the flux of talus, displacement of the landslide and pre-failure deformation of discrete rockfall events. Additionally, we found the ATLS system to be an effective tool in monitoring landslide and rockfall processes despite missing points due to poor atmospheric conditions or rainfall. Furthermore, such a system has the potential to help us better understand a wide variety of slope processes at high levels of temporal detail.

  1. Quantification of 18F-JNJ-42259152, a novel phosphodiesterase 10A PET tracer: kinetic modeling and test-retest study in human brain.

    PubMed

    Van Laere, Koen; Ahmad, Rawaha U; Hudyana, Hendra; Dubois, Kristof; Schmidt, Mark E; Celen, Sofie; Bormans, Guy; Koole, Michel

    2013-08-01

    Phosphodiesterase 10A (PDE10A) plays a central role in striatal signaling and is implicated in several neuropsychiatric disorders, such as movement disorders and schizophrenia. We performed initial brain kinetic modeling of the novel PDE10A tracer (18)F-JNJ-42259152 (2-[[4-[1-(2-(18)F-fluoroethyl)-4-(4-pyridinyl)-1H-pyrazol-3-yl]phenoxy]methyl]-3,5-dimethyl-pyridine) and studied test-retest reproducibility in healthy volunteers. Twelve healthy volunteers (5 men, 7 women; age range, 42-77 y) were scanned dynamically up to 135 min after bolus injection of 172.5 ± 10.3 MBq of (18)F-JNJ42259152. Four volunteers (2 men, 2 women) underwent retest scanning, with a mean interscan interval of 37 d. Input functions and tracer parent fractions were determined using arterial sampling and high-performance liquid chromatography analysis. Volumes of interest for the putamen, caudate nucleus, ventral striatum, substantia nigra, thalamus, frontal cortex, and cerebellum were delineated using individual volumetric T1 MR imaging scans. One-tissue (1T) and 2-tissue (2T) models were evaluated to calculate total distribution volume (VT). Simplified models were also tested to calculate binding potential (BPND), including the simplified reference tissue model (SRTM) and multilinear reference tissue model, using the frontal cortex as the optimal reference tissue. The stability of VT and BPND was assessed down to a 60-min scan time. The average intact tracer half-life in blood was 90 min. The 2T model VT values for the putamen, caudate nucleus, ventral striatum, substantia nigra, thalamus, frontal cortex, and cerebellum were 1.54 ± 0.37, 0.90 ± 0.24, 0.64 ± 0.18, 0.42 ± 0.09, 0.35 ± 0.09, 0.30 ± 0.07, and 0.36 ± 0.12, respectively. The 1T model provided significantly lower VT values, which were well correlated to the 2T VT. SRTM BPND values referenced to the frontal cortex were 3.45 ± 0.43, 1.78 ± 0.35, 1.10 ± 0.31, and 0.44 ± 0.09 for the respective target regions putamen, caudate nucleus, ventral striatum, and substantia nigra, with similar values for the multilinear reference tissue model. Good correlations were found for the target regions putamen, caudate nucleus, ventral striatum, and substantia nigra between the 2T-compartment model BPND and the SRTM BPND (r = 0.57, 0.82, 0.70, and 0.64, respectively). SRTM BPND using a 90- and 60-min acquisition interval showed low bias. Test-retest variability was 5%-19% for 2T VT and 5%-12% for BPND SRTM. Kinetic modeling of (18)F-JNJ-42259152 shows that PDE10A activity can be reliably quantified and simplified using a reference tissue model with the frontal cortex as reference and a 60-min acquisition period.

  2. Effective Dose of CT- and Fluoroscopy-Guided Perineural/Epidural Injections of the Lumbar Spine: A Comparative Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmid, Gebhard; Schmitz, Alexander; Borchardt, Dieter

    The objective of this study was to compare the effective radiation dose of perineural and epidural injections of the lumbar spine under computed tomography (CT) or fluoroscopic guidance with respect to dose-reduced protocols. We assessed the radiation dose with an Alderson Rando phantom at the lumbar segment L4/5 using 29 thermoluminescence dosimeters. Based on our clinical experience, 4-10 CT scans and 1-min fluoroscopy are appropriate. Effective doses were calculated for CT for a routine lumbar spine protocol and for maximum dose reduction; as well as for fluoroscopy in a continuous and a pulsed mode (3-15 pulses/s). Effective doses under CTmore » guidance were 1.51 mSv for 4 scans and 3.53 mSv for 10 scans using a standard protocol and 0.22 mSv and 0.43 mSv for the low-dose protocol. In continuous mode, the effective doses ranged from 0.43 to 1.25 mSv for 1-3 min of fluoroscopy. Using 1 min of pulsed fluoroscopy, the effective dose was less than 0.1 mSv for 3 pulses/s. A consequent low-dose CT protocol reduces the effective dose compared to a standard lumbar spine protocol by more than 85%. The latter dose might be expected when applying about 1 min of continuous fluoroscopy for guidance. A pulsed mode further reduces the effective dose of fluoroscopy by 80-90%.« less

  3. Sildenafil Stimulates Aqueous Humor Turnover in Rabbits

    PubMed Central

    Alvarez, Lawrence J.; Zamudio, Aldo C.; Candia, Oscar A.

    2013-01-01

    Sildenafil citrate increases ocular blood flow and accelerates the rate of anterior chamber refilling after paracentesis. The latter effect could have resulted from a reduction in outflow facility or from an increase in aqueous humor (AH) production. In this study, we used scanning ocular fluorophotometry to examine the effects of sildenafil on AH turnover, and thus, AH production in eyes of live normal rabbits. For this, the rate of aqueous humor flow (AHF) was quantified with a commercially available fluorophotometer that measured the rate of fluorescein clearance from the anterior segment, which predominantly occurs via the trabecular meshwork. After ≈ 2 hrs of control scans to determine the baseline rate of AHF, the rabbits were fed 33 mg of sildenafil and allowed ≈ 45 min for the drug to enter the systemic circulation. Thereafter, fluorescence scans were retaken for an additional 90–120 min. Sildenafil ingestion increased AHF by about 36%, from 2.31 μL/min to 3.14 μL/min (P< 0.001, as two-tailed paired data, n= 20 eyes). This observation indicates that sildenafil citrate, which is a phosphodiesterase type-5 inhibitor currently marketed as a vasodilator (e.g., Viagra, Revatio), stimulates AHF in rabbits. Our results seem consistent with reports indicating that the drug dilates intraocular arteries and augments intraocular vascular flow. These physiological responses to the agent apparently led to increased fluid entry into the anterior chamber. As such, the drug might have utility in patients with ocular hypotony resulting from insufficient AH formation. PMID:23562660

  4. Time-dependent effects of ultraviolet and nonthermal atmospheric pressure plasma on the biological activity of titanium

    NASA Astrophysics Data System (ADS)

    Choi, Sung-Hwan; Jeong, Won-Seok; Cha, Jung-Yul; Lee, Jae-Hoon; Yu, Hyung-Seog; Choi, Eun-Ha; Kim, Kwang-Mahn; Hwang, Chung-Ju

    2016-09-01

    Here, we evaluated time-dependent changes in the effects of ultraviolet (UV) and nonthermal atmospheric pressure plasma (NTAPPJ) on the biological activity of titanium compared with that of untreated titanium. Grade IV machined surface titanium discs (12-mm diameter) were used immediately and stored up to 28 days after 15-min UV or 10-min NTAPPJ treatment. Changes of surface characteristics over time were evaluated using scanning electron microscopy, surface profiling, contact angle analysis, X-ray photoelectron spectroscopy, and surface zeta-potential. Changes in biological activity over time were as determined by analysing bovine serum albumin adsorption, MC3T3-E1 early adhesion and morphometry, and alkaline phosphatase (ALP) activity between groups. We found no differences in the effects of treatment on titanium between UV or NTAPPJ over time; both treatments resulted in changes from negatively charged hydrophobic (bioinert) to positively charged hydrophilic (bioactive) surfaces, allowing enhancement of albumin adsorption, osteoblastic cell attachment, and cytoskeleton development. Although this effect may not be prolonged for promotion of cell adhesion until 4 weeks, the effects were sufficient to maintain ALP activity after 7 days of incubation. This positive effect of UV and NTAPPJ treatment can enhance the biological activity of titanium over time.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samavatian, Majid, E-mail: m.samavatian@srbiau.ac.ir; Halvaee, Ayoub; Amadeh, Ahmad Ali

    Joining mechanism of Ti/Al dissimilar alloys was studied during liquid state diffusion bonding process using Cu/Sn/Cu interlayer at 510 °C under vacuum of 7.5 × 10{sup −5} Torr for various bonding times. The microstructure and compositional changes in the joint zone were analyzed by scanning electron microscopy equipped with energy dispersive spectroscopy and X-ray diffraction. Microhardness and shear strength tests were also applied to study the mechanical properties of the joints. It was found that with an increase in bonding time, the elements of interlayer diffused into the parent metals and formed various intermetallic compounds at the interface. Diffusion processmore » led to the isothermal solidification and the bonding evolution in the joint zone. The results from mechanical tests showed that microhardness and shear strength values have a straight relation with bonding time so that the maximum shear strength of joint was obtained for a bond made with 60 min bonding time. - Highlights: • Liquid state diffusion bonding of Al2024 to Ti–6Al–4V was performed successfully. • Diffusion of the elements caused the formation of various intermetallics at the interface. • Microhardness and shear strength values have a straight relation with bonding time. • The maximum shear strength reached to 36 MPa in 60 min bonding time.« less

  6. Preparation and characterization of Polyacrylonitrile/ Manganese Dioxides- based Carbon Nanofibers via electrospinning process

    NASA Astrophysics Data System (ADS)

    Che Othman, F. E.; Yusof, N.; Jaafar, J.; Ismail, A. F.; Hasbullah, H.; Abdullah, N.; Ismail, M. S.

    2016-06-01

    This research reports the production of precursor polyacrylonitrile (PAN)/ manganese dioxide (MnO2) nanofibers (NFs) via electrospinning method followed by stabilization and carbonization processes. Nowadays, electrospinning has become a suitable method in manufacturing continuous NFs, thus it is employed to fabricate NFs in this study. The microstructural properties and adsorption competencies of the produced NFs were also studied. The NFs were prepared by electrospinning the polymer solution of Polyacrylonitrile (PAN) and Manganese Dioxide (MnO2) in, N, N-Dimethylformamide (DMF) solvent. The factors considered in this study were various polymer PAN/MnO2 concentrations which will significantly affect the specific surface area, fiber morphology and the diameter of the NFs prepared. Subsequently, heat treatment is applied by setting up the stabilization temperature at 275 °C and carbonization temperature at 800 °C with constant dwelling time (30 min). Nitrogen gas at constant rate 0.2 L/min was used for stabilization and carbonization with the stabilization rate (2 °C/min) and carbonization rate (5 °C/min). The carbon nanofibers (CNFs) produced were characterized using Scanning Electron Microscopy (SEM), Brunauer Emmett and Teller (BET) surface area and Fourier Transmission Infrared Spectroscopy (FTIR). It was found that the PAN/MnO2 CNFs were successfully produced with the carbonization temperature of 800 °C. The prepared PAN/MnO2 CNFs prepared showed an enhanced in specific surface area about two times compared to it precursor NFs.

  7. Rapid myelin water imaging in human cervical spinal cord.

    PubMed

    Ljungberg, Emil; Vavasour, Irene; Tam, Roger; Yoo, Youngjin; Rauscher, Alexander; Li, David K B; Traboulsee, Anthony; MacKay, Alex; Kolind, Shannon

    2017-10-01

    Myelin water imaging (MWI) using multi-echo T 2 relaxation is a quantitative MRI technique that can be used as an in vivo biomarker for myelin in the central nervous system. MWI using a multi-echo spin echo sequence currently takes more than 20 min to acquire eight axial slices (5 mm thickness) in the cervical spinal cord, making spinal cord MWI impractical for implementation in clinical studies. In this study, an accelerated gradient and spin echo sequence (GRASE), previously validated for brain MWI, was adapted for spinal cord MWI. Ten healthy volunteers were scanned with the GRASE sequence (acquisition time 8.5 min) and compared with the multi-echo spin echo sequence (acquisition time 23.5 min). Using region of interest analysis, myelin estimates obtained from the two sequences were found to be in good agreement (mean difference = -0.0092, 95% confidence interval =  - 0.0092 ± 0.061; regression slope = 1.01, ρ = 0.9). MWI using GRASE was shown to be highly reproducible with an average coefficient of variation of 6.1%. The results from this study show that MWI can be performed in the cervical spinal cord in less than 10 min, allowing for practical implementation in multimodal clinical studies. Magn Reson Med 78:1482-1487, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  8. Accelerated radial Fourier-velocity encoding using compressed sensing.

    PubMed

    Hilbert, Fabian; Wech, Tobias; Hahn, Dietbert; Köstler, Herbert

    2014-09-01

    Phase Contrast Magnetic Resonance Imaging (MRI) is a tool for non-invasive determination of flow velocities inside blood vessels. Because Phase Contrast MRI only measures a single mean velocity per voxel, it is only applicable to vessels significantly larger than the voxel size. In contrast, Fourier Velocity Encoding measures the entire velocity distribution inside a voxel, but requires a much longer acquisition time. For accurate diagnosis of stenosis in vessels on the scale of spatial resolution, it is important to know the velocity distribution of a voxel. Our aim was to determine velocity distributions with accelerated Fourier Velocity Encoding in an acquisition time required for a conventional Phase Contrast image. We imaged the femoral artery of healthy volunteers with ECG-triggered, radial CINE acquisition. Data acquisition was accelerated by undersampling, while missing data were reconstructed by Compressed Sensing. Velocity spectra of the vessel were evaluated by high resolution Phase Contrast images and compared to spectra from fully sampled and undersampled Fourier Velocity Encoding. By means of undersampling, it was possible to reduce the scan time for Fourier Velocity Encoding to the duration required for a conventional Phase Contrast image. Acquisition time for a fully sampled data set with 12 different Velocity Encodings was 40 min. By applying a 12.6-fold retrospective undersampling, a data set was generated equal to 3:10 min acquisition time, which is similar to a conventional Phase Contrast measurement. Velocity spectra from fully sampled and undersampled Fourier Velocity Encoded images are in good agreement and show the same maximum velocities as compared to velocity maps from Phase Contrast measurements. Compressed Sensing proved to reliably reconstruct Fourier Velocity Encoded data. Our results indicate that Fourier Velocity Encoding allows an accurate determination of the velocity distribution in vessels in the order of the voxel size. Thus, compared to normal Phase Contrast measurements delivering only mean velocities, no additional scan time is necessary to retrieve meaningful velocity spectra in small vessels. Copyright © 2013. Published by Elsevier GmbH.

  9. Impact of high pressure treatment on functional, rheological, pasting, and structural properties of lentil starch dispersions.

    PubMed

    Ahmed, Jasim; Thomas, Linu; Taher, Ayoub; Joseph, Antony

    2016-11-05

    Lentil starch (LS) dispersions (flour to water 1:4w/w) were subjected to high pressure (HP) treatment at 0.1, 400, 500 and 600MPa for 10min, followed by evaluation on the functional, particle size, rheological, pasting, and structural properties of post-process samples. Water holding capacity of pressurized starch increased with the pressure intensity due to increase in damaged starch. The amount of resistant starch increased from 5 to 6.8% after pressure treatment at 600MPa. An increase in starch granule particle size (196-207μm) was obvious after HP treatment. The lentil starch was completely gelatinized after pressure treatment at 600MPa for 10min as evidenced from differential scanning calorimetry, rheometry, X-ray diffraction (XRD) and scanning electron microscopy observation. The elastic modulus, G' of lentil starch gel was less frequency dependent, and higher in magnitude at high pressure (>500MPa) than at lower pressure range (≤400MPa). XRD analysis revealed the disappearance of two diffraction peak intensities at 14.86° and 22.82° at 600MPa for 10min, which confirms the transformation of crystalline to amorphous region of lentil starch. Pasting properties were significantly influenced by the pressure treatment especially at 600MPa, resulting in a considerable decrease in peak viscosity, breakdown and final viscosity, and an increase in peak time. It can be inferred that the functional properties of pressure-treated LS are mainly based on the structural destruction of granules. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Fast 3-T MR-guided transrectal prostate biopsy using an in-room tablet device for needle guide alignment: a feasibility study.

    PubMed

    Overduin, Christiaan G; Heidkamp, Jan; Rothgang, Eva; Barentsz, Jelle O; de Lange, Frank; Fütterer, Jurgen J

    2018-05-22

    To assess the feasibility of adding a tablet device inside the scanner room to assist needle-guide alignment during magnetic resonance (MR)-guided transrectal prostate biopsy. Twenty patients with one cancer-suspicious region (CSR) with PI-RADS score ≥ 4 on diagnostic multiparametric MRI were prospectively enrolled. Two orthogonal scan planes of an MR fluoroscopy sequence (~3 images/s) were aligned to the CSR and needle-guide pivoting point. Targeting was achieved by manipulating the needle-guide under MR fluoroscopy feedback on the in-room tablet device. Technical feasibility and targeting success were assessed. Complications and biopsy procedure times were also recorded. Needle-guide alignment with the in-room tablet device was technically successful in all patients and allowed sampling after a single alignment step in 19/20 (95%) CSRs (median size 14 mm, range: 4-45). Biopsy cores contained cancer in 18/20 patients. There were no per-procedural or post-biopsy complications. Using the tablet device, the mean time to first biopsy was 5.8 ± 1.0 min and the mean total procedure time was 23.7 ± 4.1 min. Use of an in-room tablet device to assist needle-guide alignment was feasible and safe during MR-guided transrectal prostate biopsy. Initial experience indicates potential for procedure time reduction. • Performing MR-guided prostate biopsy using an in-room tablet device is feasible. • CSRs could be sampled after a single alignment step in 19/20 patients. • The mean procedure time for biopsy with the tablet device was 23.7 min.

  11. Quantification of Dynamic 11C-Phenytoin PET Studies.

    PubMed

    Mansor, Syahir; Boellaard, Ronald; Froklage, Femke E; Bakker, Esther D M; Yaqub, Maqsood; Voskuyl, Rob A; Schwarte, Lothar A; Verbeek, Joost; Windhorst, Albert D; Lammertsma, Adriaan

    2015-09-01

    The overexpression of P-glycoprotein (Pgp) is thought to be an important mechanism of pharmacoresistance in epilepsy. Recently, (11)C-phenytoin has been evaluated preclinically as a tracer for Pgp. The aim of the present study was to assess the optimal plasma kinetic model for quantification of (11)C-phenytoin studies in humans. Dynamic (11)C-phenytoin PET scans of 6 healthy volunteers with arterial sampling were acquired twice on the same day and analyzed using single- and 2-tissue-compartment models with and without a blood volume parameter. Global and regional test-retest (TRT) variability was determined for both plasma to tissue rate constant (K1) and volume of distribution (VT). According to the Akaike information criterion, the reversible single-tissue-compartment model with blood volume parameter was the preferred plasma input model. Mean TRT variability ranged from 1.5% to 16.9% for K1 and from 0.5% to 5.8% for VT. Larger volumes of interest showed better repeatabilities than smaller regions. A 45-min scan provided essentially the same K1 and VT values as a 60-min scan. A reversible single-tissue-compartment model with blood volume seems to be a good candidate model for quantification of dynamic (11)C-phenytoin studies. Scan duration may be reduced to 45 min without notable loss of accuracy and precision of both K1 and VT, although this still needs to be confirmed under pathologic conditions. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  12. Multicenter Reproducibility of 18F-Fluciclatide PET Imaging in Subjects with Solid Tumors.

    PubMed

    Sharma, Rohini; Kallur, Kumar G; Ryu, Jin S; Parameswaran, Ramanathapuram V; Lindman, Henrik; Avril, Norbert; Gleeson, Fergus V; Lee, Jong D; Lee, Kyung-Han; O'Doherty, Michael J; Groves, Ashley M; Miller, Matthew P; Somer, Edward J; Coombes, Charles R; Aboagye, Eric O

    2015-12-01

    Integrins are upregulated on both tumor cells and associated vasculature, where they play an important role in angiogenesis and metastasis. Fluciclatide is an arginine-glycine-aspartic acid peptide with high affinity for αvβ3/αvβ5 integrin, which can be radiolabeled for PET imaging of angiogenesis. Thus, (18)F-fluciclatide is a potential biomarker of therapeutic response to antiangiogenic inhibitors. The aim of this study was to evaluate the reproducibility of (18)F-fluciclatide in multiple solid-tumor types. Thirty-nine patients underwent PET/CT scanning at 40, 65, and 90 min after injection of (18)F-fluciclatide (maximum, 370 MBq) on 2 separate days (2-9 d apart). Patients did not receive any therapy between PET/CT scans. (18)F-fluciclatide images were reported and quantitative measures of uptake were extracted using the PERCIST methodology. Intrasubject reproducibility of PET uptake in all measurable lesions was evaluated by calculating relative differences in SUV between PET scans for each lesion during the 2 imaging sessions. Thirty-nine measurable lesions were detected in 26 patients. Lesion uptake correlated strongly across imaging sessions (r = 0.92, P < 0.05, at 40 min; r = 0.94, P < 0.05, at 65 min; r = 0.94, P < 0.05, at 90 min) with a mean relative difference and SD of the relative difference of 0.006 ± 0.18 at 40 min, 0.003 ± 0.19 at 65 min, and 0.025 ± 0.20 at 90 min. This reflects 95% limits of repeatability of 35%-39% for the difference between the 2 SUV measurements or a variability of 18%-20% in agreement from that observed in well-calibrated multicenter (18)F-FDG studies. The test-retest reproducibility of (18)F-fluciclatide across multiple tumor types has been measured and shown to be acceptable. This is an important step in the development of this in vivo biomarker to identify and quantify response to antiangiogenic therapy in cancer patients. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  13. Semantic focusing allows fully automated single-layer slide scanning of cervical cytology slides.

    PubMed

    Lahrmann, Bernd; Valous, Nektarios A; Eisenmann, Urs; Wentzensen, Nicolas; Grabe, Niels

    2013-01-01

    Liquid-based cytology (LBC) in conjunction with Whole-Slide Imaging (WSI) enables the objective and sensitive and quantitative evaluation of biomarkers in cytology. However, the complex three-dimensional distribution of cells on LBC slides requires manual focusing, long scanning-times, and multi-layer scanning. Here, we present a solution that overcomes these limitations in two steps: first, we make sure that focus points are only set on cells. Secondly, we check the total slide focus quality. From a first analysis we detected that superficial dust can be separated from the cell layer (thin layer of cells on the glass slide) itself. Then we analyzed 2,295 individual focus points from 51 LBC slides stained for p16 and Ki67. Using the number of edges in a focus point image, specific color values and size-inclusion filters, focus points detecting cells could be distinguished from focus points on artifacts (accuracy 98.6%). Sharpness as total focus quality of a virtual LBC slide is computed from 5 sharpness features. We trained a multi-parameter SVM classifier on 1,600 images. On an independent validation set of 3,232 cell images we achieved an accuracy of 94.8% for classifying images as focused. Our results show that single-layer scanning of LBC slides is possible and how it can be achieved. We assembled focus point analysis and sharpness classification into a fully automatic, iterative workflow, free of user intervention, which performs repetitive slide scanning as necessary. On 400 LBC slides we achieved a scanning-time of 13.9±10.1 min with 29.1±15.5 focus points. In summary, the integration of semantic focus information into whole-slide imaging allows automatic high-quality imaging of LBC slides and subsequent biomarker analysis.

  14. Analyses of school commuting data for exposure modeling purposes.

    PubMed

    Xue, Jianping; McCurdy, Thomas; Burke, Janet; Bhaduri, Budhendra; Liu, Cheng; Nutaro, James; Patterson, Lauren

    2010-01-01

    Human exposure models often make the simplifying assumption that school children attend school in the same census tract where they live. This paper analyzes that assumption and provides information on the temporal and spatial distributions associated with school commuting. The data were obtained using Oak Ridge National Laboratory's LandScan USA population distribution model applied to Philadelphia, PA. It is a high-resolution model used to allocate individual school-aged children to both a home and school location, and to devise a minimum-time home-to-school commuting path (called a trace) between the two locations. LandScan relies heavily on Geographic Information System (GIS) data. With respect to school children attending school in their home census tract, the vast majority does not in Philadelphia. Our analyses found that: (1) about 32% of the students walk across two or more census tracts going to school and 40% of them walk across four or more census blocks; and (2) 60% drive across four or more census tracts going to school and 50% drive across 10 or more census blocks. We also find that: (3) using a 5-min commuting time interval - as opposed to the modeled "trace" - results in misclassifying the "actual" path taken in 90% of the census blocks, 70% of the block groups, and 50% of the tracts; (4) a 1-min time interval is needed to reasonably resolve time spent in the various census unit designations; and (5) approximately 50% of both the homes and schools of Philadelphia school children are located within 160 m of highly traveled roads, and 64% of the schools are located within 200 m. These findings are very important when modeling school children's exposures, especially, when ascertaining the impacts of near-roadway concentrations on their total daily body burden. As many school children also travel along these streets and roadways to get to school, a majority of children in Philadelphia are in mobile source-dominated locations most of the day. We hypothesize that exposures of school children in Philadelphia to benzene and particulate matter will be much higher than if home and school locations and commuting paths at a 1-min time resolution are not explicitly modeled in an exposure assessment. Undertaking such an assessment will be the topic of a future paper.

  15. Automated brain tissue and myelin volumetry based on quantitative MR imaging with various in-plane resolutions.

    PubMed

    Andica, C; Hagiwara, A; Hori, M; Nakazawa, M; Goto, M; Koshino, S; Kamagata, K; Kumamaru, K K; Aoki, S

    2018-05-01

    Segmented brain tissue and myelin volumes can now be automatically calculated using dedicated software (SyMRI), which is based on quantification of R 1 and R 2 relaxation rates and proton density. The aim of this study was to determine the validity of SyMRI brain tissue and myelin volumetry using various in-plane resolutions. We scanned 10 healthy subjects on a 1.5T MR scanner with in-plane resolutions of 0.8, 2.0 and 3.0mm. Two scans were performed for each resolution. The acquisition time was 7-min and 24-sec for 0.8mm, 3-min and 9-sec for 2.0mm and 1-min and 56-sec for 3.0mm resolutions. The volumes of white matter (WM), gray matter (GM), cerebrospinal fluid (CSF), non-WM/GM/CSF (NoN), brain parenchymal volume (BPV), intracranial volume (ICV) and myelin were compared between in-plane resolutions. Repeatability for each resolution was then analyzed. No significant differences in volumes measured were found between the different in-plane resolutions, except for NoN between 0.8mm and 2.0mm and between 2.0mm and 3.0mm. The repeatability error value for the WM, GM, CSF, NoN, BPV and myelin volumes relative to ICV was 0.97%, 1.01%, 0.65%, 0.86%, 1.06% and 0.25% in 0.8mm; 1.22%, 1.36%, 0.73%, 0.37%, 1.18% and 0.35% in 2.0mm and 1.18%, 1.02%, 0.96%, 0.45%, 1.36%, and 0.28% in 3.0mm resolutions. SyMRI brain tissue and myelin volumetry with low in-plane resolution and short acquisition times is robust and has a good repeatability so could be useful for follow-up studies. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  16. A novel approach to the pacemaker infection with non-thermal atmospheric pressure plasma

    NASA Astrophysics Data System (ADS)

    Zhang, Yuchen; Li, Yu; Li, Yinglong; Yu, Shuang; Li, Haiyan; Zhang, Jue

    2017-08-01

    Although the pacemaker (PM) is a key cardiac implantable electrical device for life-threatening arrhythmias treatment, the related infection is a challenge. Thus, the aim of this study is to validate cold plasma as a potential technology for the disinfection of infected pacemakers. Fifty donated PMs were cleaned and sterilized before use and then infected with Staphylococcus aureus ( S. aureus). Then, each experimental group was treated with cold plasma treatment for 1 min, 3 min, 5 min and 7 min, while the control group was immersed with sterilized water. Effectiveness of disinfection was evaluated by using CFU counting method and confocal laser scanning microscopy (CLSM). The physicochemical properties of water treated with cold plasma at different time were evaluated, including water temperature change and oxidation reduction potential (ORP). The major reactive species generated by the cold plasma equipment during cold plasma were analyzed with optical emission spectroscopy (OES). No live bacteria were detected with CFU counting method after 7 min of cold plasma treatment, which matches with the CLSM results. The ORP value of water and H2O2 concentration changed significantly after treating with cold plasma. Furthermore, reactive oxygen species (ROS) and reactive nitrogen species (RNS), especially NO, O (777 nm) and O (844 nm) were probably key inactivation agents in cold plasma treatment. These results indicate that cold plasma could be an effective technology for the disinfection of implantable devices.

  17. Mechanism analysis on finishing of reaction-sintered silicon carbide by combination of water vapor plasma oxidation and ceria slurry polishing

    NASA Astrophysics Data System (ADS)

    Shen, Xinmin; Tu, Qunzhang; Deng, Hui; Jiang, Guoliang; Yamamura, Kazuya

    2015-05-01

    Reaction-sintered silicon carbide (RS-SiC), which is considered as a promising mirror material for space telescope systems, requires a high surface property. An ultrasmooth surface with a Ra surface roughness of 0.480 nm was obtained after water vapor plasma oxidation for 90 min followed by ceria slurry polishing for 40 min. The oxidation process of RS-SiC by water vapor plasma was analyzed based on the Deal-Grove model, and the theoretical calculation results are consistent with the measured data obtained by scanning white light interferometer (SWLI), scanning electron microscopy/energy-dispersive x-ray, and atomic force microscope. The polishing process of oxidized RS-SiC by ceria slurry was investigated according to the Preston equation, which would theoretically forecast the evolutions of RS-SiC surfaces along with the increasing of polishing time, and it was experimentally verified by comparing the surface roughnesses obtained by SWLI and the surface morphologies obtained by SEM. The mechanism analysis on the finishing of RS-SiC would be effective for the optimization of water vapor plasma oxidation parameters and ceria slurry polishing parameters, which will promote the application of RS-SiC substrates by improving the surface property obtained by the oxidation-assisted polishing method.

  18. Training Midwives to Perform Basic Obstetric Point-of-Care Ultrasound in Rural Areas Using a Tablet Platform and Mobile Phone Transmission Technology-A WFUMB COE Project.

    PubMed

    Vinayak, Sudhir; Sande, Joyce; Nisenbaum, Harvey; Nolsøe, Christian Pállson

    2017-10-01

    Point-of-care ultrasound (POCUS) has become a topical subject and can be applied in a variety of ways with differing outcomes. The cost of all diagnostic procedures including obstetric ultrasound examinations is a major factor in the developing world and POCUS is only useful if it can be equated to good outcomes at a lower cost than a routine obstetric examination. The aim of this study was to assess a number of processes including accuracy of images and reports generated by midwives, performance of a tablet-sized ultrasound scanner, training of midwives to complete ultrasounds, teleradiology solution transmissions of images via internet, review of images by a radiologist, communication between midwife and radiologist, use of this technique to identify high-risk patients and improvement of the education and teleradiology model components. The midwives had no previous experience in ultrasound. They were stationed in rural locations where POCUS was available for the first time. After scanning the patients, an interim report was generated by the midwives and sent electronically together with all images to the main hospital for validation. Unique software was used to send lossless images by mobile phone using a modem. Transmission times were short and quality of images transmitted was excellent. All reports were validated by two experienced radiologists in our department and returned to the centers using the same transmission software. The transmission times, quality of scans, quality of reports and other parameters were recorded and monitored. Analysis showed excellent correlation between provisional and validated reports. Reporting accuracy of scans performed by the midwives was 99.63%. Overall flow turnaround time (from patient presentation to validated report) was initially 35 min but reduced to 25 min. The unique mobile phone transmission was faultless and there was no degradation of image quality. We found excellent correlation between final outcomes of the pregnancies and diagnoses on the basis of reports generated by the midwives. Only 1 discrepancy was found in the midwives' reports. Scan results versus actual outcomes revealed 2 discrepancies in the 20 patients identified as high risk. In conclusion, we found that it is valuable to train midwives in POCUS to use an ultrasound tablet device and transmit images and reports via the internet to radiologists for review of accuracy. This focus on the identification of high-risk patients can be valuable in a remote healthcare facility. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  19. [18F]CFT [(18F)WIN 35,428], a radioligand to study the dopamine transporter with PET: characterization in human subjects.

    PubMed

    Laakso, A; Bergman, J; Haaparanta, M; Vilkman, H; Solin, O; Hietala, J

    1998-03-01

    We have characterized the usage of [18F]CFT (also known as [18F]WIN 35,428) as a radioligand for in vivo studies of human dopamine transporter by PET. CFT was labeled with 18F to a high specific activity, and dynamic PET scans were conducted in healthy volunteers at various time points up to 5 h from [18F]CFT injection. The regional distribution of [18F]CFT uptake correlated well with the known distribution of dopaminergic nerve terminals in the human brain and also with that of other dopamine transporter radioligands. Striatal binding peaked at 225 min after injection and declined thereafter, demonstrating the reversible nature of the binding to the dopamine transporter. Therefore, due to the relatively long half-life of 18F (109.8 min), PET scans with [18F]CFT could easily be conducted during the binding equilibrium, allowing estimation of Bmax/Kd values (i.e., binding potential). Binding potentials for putamen and caudate measured at equilibrium were 4.79+/-0.11 and 4.50+/-0.23, respectively. We were able to also visualize midbrain dopaminergic neurons (substantia nigra) with [18F]CFT in some subjects. In conclusion, the labeling of CFT with 18F allows PET scans to be conducted at binding equilibrium, and therefore a high signal-to-noise ratio and reliable quantification of binding potential can be achieved. With a high resolution 3D PET scanner, the quantification of extrastriatal dopamine transporters should become possible.

  20. Synthesis of Cobalt Powder by Reduction of Cobalt Oxide with Ethanol

    NASA Astrophysics Data System (ADS)

    Cetinkaya, S.; Eroglu, S.

    2018-03-01

    In this study, ethanol (C2H5OH) was used as a reducing agent for Co powder synthesis from Co3O4. It aimed to investigate the effects of temperature (700-900 K), reaction time (0-60 min), and gas flow rate on the reaction behavior of Co3O4 in ethanol flow. Mass measurement, x-ray diffraction, and scanning electron microscopy techniques were used to characterize the products. Single-phase Co powders with mean particle sizes of 0.51 μm and 0.70 μm were obtained within 10 min at 800 K and 900 K, respectively. Above 800 K, external mass transfer controlled the reduction process (Q a = 0.52 kJ/mole). Below 800 K, the process (Q a = 20.17 kJ/mole) was partly controlled by external mass transfer and partly by intrinsic chemical reaction kinetics. Significant C uptake was observed at 700 K and 750 K within 60 min. The reactions were discussed in the light of thermodynamic results, which predicted Co formation from Co3O4 and C2H5OH.

  1. Investigating brain response to music: a comparison of different fMRI acquisition schemes.

    PubMed

    Mueller, Karsten; Mildner, Toralf; Fritz, Thomas; Lepsien, Jöran; Schwarzbauer, Christian; Schroeter, Matthias L; Möller, Harald E

    2011-01-01

    Functional magnetic resonance imaging (fMRI) in auditory experiments is a challenge, because the scanning procedure produces considerable noise that can interfere with the auditory paradigm. The noise might either mask the auditory material presented, or interfere with stimuli designed to evoke emotions because it sounds loud and rather unpleasant. Therefore, scanning paradigms that allow interleaved auditory stimulation and image acquisition appear to be advantageous. The sparse temporal sampling (STS) technique uses a very long repetition time in order to achieve a stimulus presentation in the absence of scanner noise. Although only relatively few volumes are acquired for the resulting data sets, there have been recent studies where this method has furthered remarkable results. A new development is the interleaved silent steady state (ISSS) technique. Compared with STS, this method is capable of acquiring several volumes in the time frame between the auditory trials (while the magnetization is kept in a steady state during stimulus presentation). In order to draw conclusions about the optimum fMRI procedure with auditory stimulation, different echo-planar imaging (EPI) acquisition schemes were compared: Continuous scanning, STS, and ISSS. The total acquisition time of each sequence was adjusted to about 12.5 min. The results indicate that the ISSS approach exhibits the highest sensitivity in detecting subtle activity in sub-cortical brain regions. Copyright © 2010 Elsevier Inc. All rights reserved.

  2. VizieR Online Data Catalog: Faint OB stars between Car and Cen (Lynga 1968)

    NASA Astrophysics Data System (ADS)

    Lynga, G.

    2016-03-01

    The instrument used is the 50/65/175cm Schmidt telescope of the Uppsala Southern Station at Mount Stromlo. The objective prism gives a dispersion of 470Angstrom/mm et Hγ. The emulsion has constantly been Kodak IIa-O, the exposure time 20min, and the width of the spectra 0.2mm. A 12 degree zone centered on the galactic equator has been scanned for OB stars. Accurate positions of the stars were added in 2016, using the results from B. Skiff (Lowell Obs.) (2 data files).

  3. Identification of tower-wake distortions using sonic anemometer and lidar measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine; Quelet, Paul T.; Choukulkar, Aditya

    The eXperimental Planetary boundary layer Instrumentation Assessment (XPIA) field campaign took place in March through May 2015 at the Boulder Atmospheric Observatory, utilizing its 300 m meteorological tower, instrumented with two sonic anemometers mounted on opposite sides of the tower at six heights. This allowed for at least one sonic anemometer at each level to be upstream of the tower at all times and for identification of the times when a sonic anemometer is in the wake of the tower frame. Other instrumentation, including profiling and scanning lidars aided in the identification of the tower wake. Here we compare pairsmore » of sonic anemometers at the same heights to identify the range of directions that are affected by the tower for each of the opposing booms. The mean velocity and turbulent kinetic energy are used to quantify the wake impact on these first- and second-order wind measurements, showing up to a 50% reduction in wind speed and an order of magnitude increase in turbulent kinetic energy. Comparisons of wind speeds from profiling and scanning lidars confirmed the extent of the tower wake, with the same reduction in wind speed observed in the tower wake, and a speed-up effect around the wake boundaries. Wind direction differences between pairs of sonic anemometers and between sonic anemometers and lidars can also be significant, as the flow is deflected by the tower structure. Comparisons of lengths of averaging intervals showed a decrease in wind speed deficit with longer averages, but the flow deflection remains constant over longer averages. Furthermore, asymmetry exists in the tower effects due to the geometry and placement of the booms on the triangular tower. An analysis of the percentage of observations in the wake that must be removed from 2 min mean wind speed and 20 min turbulent values showed that removing even small portions of the time interval due to wakes impacts these two quantities. Furthermorew, a vast majority of intervals have no observations in the tower wake, so removing the full 2 or 20 min intervals does not diminish the XPIA dataset.« less

  4. Identification of tower-wake distortions using sonic anemometer and lidar measurements

    DOE PAGES

    McCaffrey, Katherine; Quelet, Paul T.; Choukulkar, Aditya; ...

    2017-02-02

    The eXperimental Planetary boundary layer Instrumentation Assessment (XPIA) field campaign took place in March through May 2015 at the Boulder Atmospheric Observatory, utilizing its 300 m meteorological tower, instrumented with two sonic anemometers mounted on opposite sides of the tower at six heights. This allowed for at least one sonic anemometer at each level to be upstream of the tower at all times and for identification of the times when a sonic anemometer is in the wake of the tower frame. Other instrumentation, including profiling and scanning lidars aided in the identification of the tower wake. Here we compare pairsmore » of sonic anemometers at the same heights to identify the range of directions that are affected by the tower for each of the opposing booms. The mean velocity and turbulent kinetic energy are used to quantify the wake impact on these first- and second-order wind measurements, showing up to a 50% reduction in wind speed and an order of magnitude increase in turbulent kinetic energy. Comparisons of wind speeds from profiling and scanning lidars confirmed the extent of the tower wake, with the same reduction in wind speed observed in the tower wake, and a speed-up effect around the wake boundaries. Wind direction differences between pairs of sonic anemometers and between sonic anemometers and lidars can also be significant, as the flow is deflected by the tower structure. Comparisons of lengths of averaging intervals showed a decrease in wind speed deficit with longer averages, but the flow deflection remains constant over longer averages. Furthermore, asymmetry exists in the tower effects due to the geometry and placement of the booms on the triangular tower. An analysis of the percentage of observations in the wake that must be removed from 2 min mean wind speed and 20 min turbulent values showed that removing even small portions of the time interval due to wakes impacts these two quantities. Furthermorew, a vast majority of intervals have no observations in the tower wake, so removing the full 2 or 20 min intervals does not diminish the XPIA dataset.« less

  5. Radiation injury vs. recurrent brain metastasis: combining textural feature radiomics analysis and standard parameters may increase 18F-FET PET accuracy without dynamic scans.

    PubMed

    Lohmann, Philipp; Stoffels, Gabriele; Ceccon, Garry; Rapp, Marion; Sabel, Michael; Filss, Christian P; Kamp, Marcel A; Stegmayr, Carina; Neumaier, Bernd; Shah, Nadim J; Langen, Karl-Josef; Galldiks, Norbert

    2017-07-01

    We investigated the potential of textural feature analysis of O-(2-[ 18 F]fluoroethyl)-L-tyrosine ( 18 F-FET) PET to differentiate radiation injury from brain metastasis recurrence. Forty-seven patients with contrast-enhancing brain lesions (n = 54) on MRI after radiotherapy of brain metastases underwent dynamic 18 F-FET PET. Tumour-to-brain ratios (TBRs) of 18 F-FET uptake and 62 textural parameters were determined on summed images 20-40 min post-injection. Tracer uptake kinetics, i.e., time-to-peak (TTP) and patterns of time-activity curves (TAC) were evaluated on dynamic PET data from 0-50 min post-injection. Diagnostic accuracy of investigated parameters and combinations thereof to discriminate between brain metastasis recurrence and radiation injury was compared. Diagnostic accuracy increased from 81 % for TBR mean alone to 85 % when combined with the textural parameter Coarseness or Short-zone emphasis. The accuracy of TBR max alone was 83 % and increased to 85 % after combination with the textural parameters Coarseness, Short-zone emphasis, or Correlation. Analysis of TACs resulted in an accuracy of 70 % for kinetic pattern alone and increased to 83 % when combined with TBR max . Textural feature analysis in combination with TBRs may have the potential to increase diagnostic accuracy for discrimination between brain metastasis recurrence and radiation injury, without the need for dynamic 18 F-FET PET scans. • Textural feature analysis provides quantitative information about tumour heterogeneity • Textural features help improve discrimination between brain metastasis recurrence and radiation injury • Textural features might be helpful to further understand tumour heterogeneity • Analysis does not require a more time consuming dynamic PET acquisition.

  6. Terrestrial laser scanning for biomass assessment and tree reconstruction: improved processing efficiency

    NASA Astrophysics Data System (ADS)

    Alboabidallah, Ahmed; Martin, John; Lavender, Samantha; Abbott, Victor

    2017-09-01

    Terrestrial Laser Scanning (TLS) processing for biomass mapping involves large data volumes, and often includes relatively slow 3D object fitting steps that increase the processing time. This study aimed to test new features that can speed up the overall processing time. A new type of 3D voxel is used, where the horizontal layers are parallel to the Digital Terrain Model. This voxel type allows procedures to extract tree diameters using just one layer, but still gives direct tree-height estimations. Layer intersection is used to emphasize the trunks as upright standing objects, which are detected in the spatially segmented intersection of the breast-height voxels and then extended upwards and downwards. The diameters were calculated by fitting elliptical cylinders to the laser points in the detected trunk segments. Non-trunk segments, used in sub-tree- structures, were found using the parent-child relationships between successive layers. The branches were reconstructed by skeletonizing each sub-tree branch, and the biomass was distributed statistically amongst the weighted skeletons. The procedure was applied to nine plots within the UK. The average correlation coefficients between reconstructed and directly measured tree diameters, heights and branches were R2 = 0.92, 0.97 and 0.59 compared to 0.91, 0.95, and 0.63 when cylindrical fitting was used. The average time to apply the method reduced from 5hrs:18mins per plot, for the conventional methods, to 2hrs:24mins when the same hardware and software libraries were used with the 3D voxels. These results indicate that this 3D voxel method can produce, much more quickly, results of a similar accuracy that would improve efficiency if applied to projects with large volume TLS datasets.

  7. Deposition of SiC x H y O z thin film on epoxy resin by nanosecond pulsed APPJ for improving the surface insulating performance

    NASA Astrophysics Data System (ADS)

    Qing, XIE; Haofan, LIN; Shuai, ZHANG; Ruixue, WANG; Fei, KONG; Tao, SHAO

    2018-02-01

    Non-thermal plasma surface modification for epoxy resin (EP) to improve the insulation properties has wide application prospects in gas insulated switchgear and gas insulated transmission line. In this paper, a pulsed Ar dual dielectrics atmospheric-pressure plasma jet (APPJ) was used for SiC x H y O z thin film deposition on EP samples. The film deposition was optimized by varying the treatment time while other parameters were kept at constants (treatment distance: 10 mm, precursor flow rate: 0.6 l min-1, maximum instantaneous power: 3.08 kW and single pulse energy: 0.18 mJ). It was found that the maximum value of flashover voltages for negative and positive voltage were improved by 18% and 13% when the deposition time was 3 min, respectively. The flashover voltage reduced as treatment time increased. Moreover, all the surface conductivity, surface charge dissipation rate and surface trap level distribution reached an optimal value when thin film deposition time was 3 min. Other measurements, such as atomic force microscopy and scanning electron microscope for EP surface morphology, Fourier transform infrared spectroscopy and x-ray photoelectron spectroscopy for EP surface compositions, optical emission spectra for APPJ deposition process were carried out to better understand the deposition processes and mechanisms. The results indicated that the original organic groups (C-H, C-C, C=O, C=C) were gradually replaced by the Si containing inorganic groups (Si-O-Si and Si-OH). The reduction of C=O in ester group and C=C in p-substituted benzene of the EP samples might be responsible for shallowing the trap level and then enhancing the flashover voltage. However, when the plasma treatment time was longer than 3 min, the significant increase of the surface roughness might increase the trap level depth and then deteriorate the flashover performance.

  8. Monitoring of exocytosis and endocytosis of insulin secretory granules in the pancreatic beta-cell line MIN6 using pH-sensitive green fluorescent protein (pHluorin) and confocal laser microscopy.

    PubMed

    Ohara-Imaizumi, Mica; Nakamichi, Yoko; Tanaka, Toshiaki; Katsuta, Hidenori; Ishida, Hitoshi; Nagamatsu, Shinya

    2002-04-01

    The dynamics of exocytosis/endocytosis of insulin secretory granules in pancreatic beta-cells remains to be clarified. In the present study, we visualized and analysed the motion of insulin secretory granules in MIN6 cells using pH-sensitive green fluorescent protein (pHluorin) fused to either insulin or the vesicle membrane protein, phogrin. In order to monitor insulin exocytosis, pHluorin, which is brightly fluorescent at approximately pH 7.4, but not at approximately pH 5.0, was attached to the C-terminus of insulin. To monitor the motion of insulin secretory granules throughout exocytosis/endocytosis, pHluorin was inserted between the third and fourth amino acids after the identified signal-peptide cleavage site of rat phogrin cDNA. Using this method of cDNA construction, pHluorin was located in the vesicle lumen, which may enable discrimination of the unfused acidic secretory granules from the fused neutralized ones. In MIN6 cells expressing insulin-pHluorin, time-lapse confocal laser scanning microscopy (5 or 10 s intervals) revealed the appearance of fluorescent spots by depolarization after stimulation with 50 mM KCl and 22 mM glucose. The number of these spots in the image at the indicated times was counted and found to be consistent with the results of insulin release measured by RIA during the time course. In MIN6 cells expressing phogrin-pHluorin, data showed that fluorescent spots appeared following high KCl stimulation and remained stationary for a while, moved on the plasma membrane and then disappeared. Thus we demonstrate the visualized motion of insulin granule exocytosis/endocytosis using the pH-sensitive marker, pHluorin.

  9. Evaluation of articular cartilage in patients with femoroacetabular impingement (FAI) using T2* mapping at different time points at 3.0 Tesla MRI: a feasibility study.

    PubMed

    Apprich, S; Mamisch, T C; Welsch, G H; Bonel, H; Siebenrock, K A; Kim, Y-J; Trattnig, S; Dudda, M

    2012-08-01

    To define the feasibility of utilizing T2* mapping for assessment of early cartilage degeneration prior to surgery in patients with symptomatic femoroacetabular impingement (FAI), we compared cartilage of the hip joint in patients with FAI and healthy volunteers using T2* mapping at 3.0 Tesla over time. Twenty-two patients (13 females and 9 males; mean age 28.1 years) with clinical signs of FAI and Tönnis grade ≤ 1 on anterior-posterior x-ray and 35 healthy age-matched volunteers were examined at a 3 T MRI using a flexible body coil. T2* maps were calculated from sagittal- and coronal-oriented gradient-multi-echo sequences using six echoes (TR 125, TE 4.41/8.49/12.57/16.65/20.73/24.81, scan time 4.02 min), both measured at beginning and end of the scan (45 min time span between measurements). Region of interest analysis was manually performed on four consecutive slices for superior and anterior cartilage. Mean T2* values were compared among patients and volunteers, as well as over time using analysis of variance and Student's t-test. Whereas quantitative T2* values for the first measurement did not reveal significant differences between patients and volunteers, either for sagittal (p = 0.644) or coronal images (p = 0.987), at the first measurement, a highly significant difference (p ≤ 0.004) was found for both measurements with time after unloading of the joint. Over time we found decreasing mean T2* values for patients, in contrast to increasing mean T2* relaxation times in volunteers. The study proved the feasibility of utilizing T2* mapping for assessment of early cartilage degeneration in the hip joint in FAI patients at 3 Tesla to predict possible success of joint-preserving surgery. However, we suggest the time point for measuring T2* as an MR biomarker for cartilage and the changes in T2* over time to be of crucial importance for designing an MR protocol in patients with FAI.

  10. Comprehensive Population-Averaged Arterial Input Function for Dynamic Contrast–Enhanced vMagnetic Resonance Imaging of Head and Neck Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Onxley, Jennifer D.; Yoo, David S.; Muradyan, Naira

    2014-07-01

    Purpose: To generate a population-averaged arterial input function (PA-AIF) for quantitative analysis of dynamic contrast-enhanced MRI data in head and neck cancer patients. Methods and Materials: Twenty patients underwent dynamic contrast-enhanced MRI during concurrent chemoradiation therapy. Imaging consisted of 2 baseline scans 1 week apart (B1/B2) and 1 scan after 1 week of chemoradiation therapy (Wk1). Regions of interest (ROIs) in the right and left carotid arteries were drawn on coronal images. Plasma concentration curves of all ROIs were averaged and fit to a biexponential decay function to obtain the final PA-AIF (AvgAll). Right-sided and left-sided ROI plasma concentration curves were averagedmore » separately to obtain side-specific AIFs (AvgRight/AvgLeft). Regions of interest were divided by time point to obtain time-point-specific AIFs (AvgB1/AvgB2/AvgWk1). The vascular transfer constant (K{sub trans}) and the fractional extravascular, extracellular space volume (V{sub e}) for primaries and nodes were calculated using the AvgAll AIF, the appropriate side-specific AIF, and the appropriate time-point-specific AIF. Median K{sub trans} and V{sub e} values derived from AvgAll were compared with those obtained from the side-specific and time-point-specific AIFs. The effect of using individual AIFs was also investigated. Results: The plasma parameters for AvgAll were a{sub 1,2} = 27.11/17.65 kg/L, m{sub 1,2} = 11.75/0.21 min{sup −1}. The coefficients of repeatability (CRs) for AvgAll versus AvgLeft were 0.04 min{sup −1} for K{sub trans} and 0.02 for V{sub e}. For AvgAll versus AvgRight, the CRs were 0.08 min{sup −1} for K{sub trans} and 0.02 for V{sub e}. When AvgAll was compared with AvgB1/AvgB2/AvgWk1, the CRs were slightly higher: 0.32/0.19/0.78 min{sup −1}, respectively, for K{sub trans}; and 0.07/0.08/0.09 for V{sub e}. Use of a PA-AIF was not significantly different from use of individual AIFs. Conclusion: A PA-AIF for head and neck cancer was generated that accounts for differences in right carotid artery versus left carotid artery, day-to-day fluctuations, and early treatment-induced changes. The small CRs obtained for K{sub trans} and V{sub e} indicate that side-specific AIFs are not necessary. However, a time-point-specific AIF may improve pharmacokinetic accuracy.« less

  11. Validating New Software for Semiautomated Liver Volumetry--Better than Manual Measurement?

    PubMed

    Noschinski, L E; Maiwald, B; Voigt, P; Wiltberger, G; Kahn, T; Stumpp, P

    2015-09-01

    This prospective study compared a manual program for liver volumetry with semiautomated software. The hypothesis was that the semiautomated software would be faster, more accurate and less dependent on the evaluator's experience. Ten patients undergoing hemihepatectomy were included in this IRB approved study after written informed consent. All patients underwent a preoperative abdominal 3-phase CT scan, which was used for whole liver volumetry and volume prediction for the liver part to be resected. Two different types of software were used: 1) manual method: borders of the liver had to be defined per slice by the user; 2) semiautomated software: automatic identification of liver volume with manual assistance for definition of Couinaud segments. Measurements were done by six observers with different experience levels. Water displacement volumetry immediately after partial liver resection served as the gold standard. The resected part was examined with a CT scan after displacement volumetry. Volumetry of the resected liver scan showed excellent correlation to water displacement volumetry (manual: ρ = 0.997; semiautomated software: ρ = 0.995). The difference between the predicted volume and the real volume was significantly smaller with the semiautomated software than with the manual method (33% vs. 57%, p = 0.002). The semiautomated software was almost four times faster for volumetry of the whole liver (manual: 6:59 ± 3:04 min; semiautomated: 1:47 ± 1:11 min). Both methods for liver volumetry give an estimated liver volume close to the real one. The tested semiautomated software is faster, more accurate in predicting the volume of the resected liver part, gives more reproducible results and is less dependent on the user's experience. Both tested types of software allow exact volumetry of resected liver parts. Preoperative prediction can be performed more accurately with the semiautomated software. The semiautomated software is nearly four times faster than the tested manual program and less dependent on the user's experience. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Use of High Resolution 3D Diffusion Tensor Imaging to Study Brain White Matter Development in Live Neonatal Rats

    PubMed Central

    Cai, Yu; McMurray, Matthew S.; Oguz, Ipek; Yuan, Hong; Styner, Martin A.; Lin, Weili; Johns, Josephine M.; An, Hongyu

    2011-01-01

    High resolution diffusion tensor imaging (DTI) can provide important information on brain development, yet it is challenging in live neonatal rats due to the small size of neonatal brain and motion-sensitive nature of DTI. Imaging in live neonatal rats has clear advantages over fixed brain scans, as longitudinal and functional studies would be feasible to understand neuro-developmental abnormalities. In this study, we developed imaging strategies that can be used to obtain high resolution 3D DTI images in live neonatal rats at postnatal day 5 (PND5) and PND14, using only 3 h of imaging acquisition time. An optimized 3D DTI pulse sequence and appropriate animal setup to minimize physiological motion artifacts are the keys to successful high resolution 3D DTI imaging. Thus, a 3D rapid acquisition relaxation enhancement DTI sequence with twin navigator echoes was implemented to accelerate imaging acquisition time and minimize motion artifacts. It has been suggested that neonatal mammals possess a unique ability to tolerate mild-to-moderate hypothermia and hypoxia without long term impact. Thus, we additionally utilized this ability to minimize motion artifacts in magnetic resonance images by carefully suppressing the respiratory rate to around 15/min for PND5 and 30/min for PND14 using mild-to-moderate hypothermia. These imaging strategies have been successfully implemented to study how the effect of cocaine exposure in dams might affect brain development in their rat pups. Image quality resulting from this in vivo DTI study was comparable to ex vivo scans. fractional anisotropy values were also similar between the live and fixed brain scans. The capability of acquiring high quality in vivo DTI imaging offers a valuable opportunity to study many neurological disorders in brain development in an authentic living environment. PMID:22013426

  13. Screening of CO2 Laser (10.6 μm) Parameters for Prevention of Enamel Erosion

    PubMed Central

    Yu, Hao; de Paula Eduardo, Carlos; Meister, Jörg; Lampert, Friedrich; Attin, Thomas; Wiegand, Annette

    2012-01-01

    Abstract Objective: The aim of this study was to screen CO2 laser (10.6 μm) parameters to increase enamel resistance to a continuous-flow erosive challenge. Background data: A new clinical CO2 laser providing pulses of hundreds of microseconds, a range known to increase tooth acid-resistance, has been introduced in the market. Methods: Different laser parameters were tested in 12 groups (n=20) with varying fluences from 0.1 to 0.9 J/cm2, pulse durations from 80 to 400 μs and repetition rates from 180 to 700 Hz. Non-lased samples (n=30) served as controls. All samples were eroded by exposure to hydrochloric acid (pH 2.6) under continuous acid flow (60 μL/min). Calcium and phosphate release into acid was monitored colorimetrically at 30 sec intervals up to 5 min and at 1 min intervals up to a total erosion time of 15 min. Scanning electron microscopic (SEM) analysis was performed in lased samples (n=3). Data were statistically analysed by one-way ANOVA (p<0.05) and Dunnett's post-hoc tests. Results: Calcium and phosphate release were significantly reduced by a maximum of 20% over time in samples irradiated with 0.4 J/cm2 (200μs) at 450 Hz. Short-time reduction of calcium loss (≤1.5 min) could be also achieved by irradiation with 0.7 J/cm2 (300μs) at 200 and 300 Hz. Both parameters revealed surface modification. Conclusions: A set of CO2 laser parameters was found that could significantly reduce enamel mineral loss (20%) under in vitro erosive conditions. However, as all parameters also caused surface cracking, they are not recommended for clinical use. PMID:22462778

  14. Microstructure and Corrosion Behavior of Laser Synthesized Cobalt Based Powder on Ti-6Al-4V

    NASA Astrophysics Data System (ADS)

    Adesina, O. S.; Popoola, A. P. I.; Pityana, S. L.; Oloruntoba, D. T.

    2018-05-01

    The corrosion behavior of titanium alloys when used for various dynamic offshore components has been a major concern of titanium drilling risers in deepwater energy extraction. A way of achieving specified requirement is the development of coatings suitable to protect the base material against corrosion. In this work, laser cladding technique which is known as a leading edge due to its distinctive properties and outcomes was used in synthesizing Co-based powder on titanium alloy. The processing parameters used were laser power of 900W; scan speed of 0.6 to 1.2 m/min; powderfeedrate1.0g/min;beamspotsize3mm;gasflowrate1.2L/min.The effects of cobalt addition and laser parameters on corrosion behavior of laser clad Ti6AL4V coating in 0.5M sulfuric medium were investigated using linear potentiodynamic polarization. The changes in microstructure and corrosion behavior were analyzed using scanning electron microscopy (SEM) while the X –ray diffraction (XRD) indicates the intermetallics in the coatings. Results showed that the coatings displayed good metallurgical bonding with dendritic formations between the coatings and the substrate. The anodic current density increased with lower scan speed. However, the corrosion current densities of laser-clad samples were lower than Ti6Al4V alloy.

  15. 3D sensitivity encoded ellipsoidal MR spectroscopic imaging of gliomas at 3T☆

    PubMed Central

    Ozturk-Isik, Esin; Chen, Albert P.; Crane, Jason C.; Bian, Wei; Xu, Duan; Han, Eric T.; Chang, Susan M.; Vigneron, Daniel B.; Nelson, Sarah J.

    2010-01-01

    Purpose The goal of this study was to implement time efficient data acquisition and reconstruction methods for 3D magnetic resonance spectroscopic imaging (MRSI) of gliomas at a field strength of 3T using parallel imaging techniques. Methods The point spread functions, signal to noise ratio (SNR), spatial resolution, metabolite intensity distributions and Cho:NAA ratio of 3D ellipsoidal, 3D sensitivity encoding (SENSE) and 3D combined ellipsoidal and SENSE (e-SENSE) k-space sampling schemes were compared with conventional k-space data acquisition methods. Results The 3D SENSE and e-SENSE methods resulted in similar spectral patterns as the conventional MRSI methods. The Cho:NAA ratios were highly correlated (P<.05 for SENSE and P<.001 for e-SENSE) with the ellipsoidal method and all methods exhibited significantly different spectral patterns in tumor regions compared to normal appearing white matter. The geometry factors ranged between 1.2 and 1.3 for both the SENSE and e-SENSE spectra. When corrected for these factors and for differences in data acquisition times, the empirical SNRs were similar to values expected based upon theoretical grounds. The effective spatial resolution of the SENSE spectra was estimated to be same as the corresponding fully sampled k-space data, while the spectra acquired with ellipsoidal and e-SENSE k-space samplings were estimated to have a 2.36–2.47-fold loss in spatial resolution due to the differences in their point spread functions. Conclusion The 3D SENSE method retained the same spatial resolution as full k-space sampling but with a 4-fold reduction in scan time and an acquisition time of 9.28 min. The 3D e-SENSE method had a similar spatial resolution as the corresponding ellipsoidal sampling with a scan time of 4:36 min. Both parallel imaging methods provided clinically interpretable spectra with volumetric coverage and adequate SNR for evaluating Cho, Cr and NAA. PMID:19766422

  16. Dual Contrast CT Method Enables Diagnostics of Cartilage Injuries and Degeneration Using a Single CT Image.

    PubMed

    Saukko, Annina E A; Honkanen, Juuso T J; Xu, Wujun; Väänänen, Sami P; Jurvelin, Jukka S; Lehto, Vesa-Pekka; Töyräs, Juha

    2017-12-01

    Cartilage injuries may be detected using contrast-enhanced computed tomography (CECT) by observing variations in distribution of anionic contrast agent within cartilage. Currently, clinical CECT enables detection of injuries and related post-traumatic degeneration based on two subsequent CT scans. The first scan allows segmentation of articular surfaces and lesions while the latter scan allows evaluation of tissue properties. Segmentation of articular surfaces from the latter scan is difficult since the contrast agent diffusion diminishes the image contrast at surfaces. We hypothesize that this can be overcome by mixing anionic contrast agent (ioxaglate) with bismuth oxide nanoparticles (BINPs) too large to diffuse into cartilage, inducing a high contrast at the surfaces. Here, a dual contrast method employing this mixture is evaluated by determining the depth-wise X-ray attenuation profiles in intact, enzymatically degraded, and mechanically injured osteochondral samples (n = 3 × 10) using a microCT immediately and at 45 min after immersion in contrast agent. BiNPs were unable to diffuse into cartilage, producing high contrast at articular surfaces. Ioxaglate enabled the detection of enzymatic and mechanical degeneration. In conclusion, the dual contrast method allowed detection of injuries and degeneration simultaneously with accurate cartilage segmentation using a single scan conducted at 45 min after contrast agent administration.

  17. SU-E-J-153: MRI Based, Daily Adaptive Radiotherapy for Rectal Cancer: Contour Adaptation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kleijnen, J; Burbach, M; Verbraeken, T

    2014-06-01

    Purpose: A major hurdle in adaptive radiotherapy is the adaptation of the planning MRI's delineations to the daily anatomy. We therefore investigate the accuracy and time needed for online clinical target volume (CTV) adaptation by radiation therapists (RTT), to be used in MRI-guided adaptive treatments on a MRI-Linac (MRL). Methods: Sixteen patients, diagnosed with early stage rectal cancer, underwent a T2-weighted MRI prior to each fraction of short-course radiotherapy, resulting in 4–5 scans per patient. On these scans, the CTV was delineated according to guidelines by an experienced radiation oncologist (RO) and considered to be the gold standard. For eachmore » patient, the first MRI was considered as the planning MRI and matched on bony anatomy to the 3–4 daily MRIs. The planning MRI's CTV delineation was rigidly propagated to the daily MRI scans as a proposal for adaptation. Three RTTs in training started the adaptation of the CTV conform guidelines, after a two hour training lecture and a two patient (n=7) training set. To assess the inter-therapist variation, all three RTTs altered delineations of 3 patients (n=12). One RTT altered the CTV delineations (n=53) of the remaining 11 patients. Time needed for adaptation of the CTV to guidelines was registered.As a measure of agreement, the conformity index (CI) was determined between the RTTs' delineations as a group. Dice similarity coefficients were determined between delineations of the RTT and the RO. Results: We found good agreement between RTTs' and RO's delineations (average Dice=0.91, SD=0.03). Furthermore, the inter-observer agreement between the RTTs was high (average CI=0.94, SD=0.02). Adaptation time reduced from 10:33 min (SD= 3:46) to 2:56 min (SD=1:06) between the first and last ten delineations, respectively. Conclusion: Daily CTV adaptation by RTTs, seems a feasible and safe way to introduce daily, online MRI-based plan adaptation for a MRL.« less

  18. 3D evaluation of the effect of disinfectants on dimensional accuracy and stability of two elastomeric impression materials.

    PubMed

    Soganci, Gokce; Cinar, Duygu; Caglar, Alper; Yagiz, Ayberk

    2018-05-31

    The aim of this study was to determine and compare the dimensional changes of polyether and vinyl polyether siloxane impression materials under immersion disinfection with two different disinfectants in three time periods. Impressions were obtained from an edentulous master model. Sodium hypochlorite (5.25%) and glutaraldehyde (2%) were used for disinfection and measurements were done 30 min later after making impression before disinfection, after required disinfection period (10 min), and after 24 h storage at room temperature. Impressions were scanned using 3D scanner with 10 microns accuracy and 3D software was used to evaluate the dimensional changes with superimpositioning. Positive and negative deviations were calculated and compared with master model. There was no significant difference between two elastomeric impression materials (p>0.05). It was concluded that dimensional accuracy and stability of two impression materials were excellent and similar.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howard, Michelle, E-mail: howard.michelle1@mayo.edu; Beltran, Chris; Mayo, Charles S.

    Purpose: To investigate the influence of the minimum monitor unit (MU) on the quality of clinical treatment plans for scanned proton therapy. Methods: Delivery system characteristics limit the minimum number of protons that can be delivered per spot, resulting in a min-MU limit. Plan quality can be impacted by the min-MU limit. Two sites were used to investigate the impact of min-MU on treatment plans: pediatric brain tumor at a depth of 5–10 cm; a head and neck tumor at a depth of 1–20 cm. Three-field, intensity modulated spot scanning proton plans were created for each site with the followingmore » parameter variations: min-MU limit range of 0.0000–0.0060; and spot spacing range of 2–8 mm. Comparisons were based on target homogeneity and normal tissue sparing. For the pediatric brain, two versions of the treatment planning system were also compared to judge the effects of the min-MU limit based on when it is accounted for in the optimization process (Eclipse v.10 and v.13, Varian Medical Systems, Palo Alto, CA). Results: The increase of the min-MU limit with a fixed spot spacing decreases plan quality both in homogeneous target coverage and in the avoidance of critical structures. Both head and neck and pediatric brain plans show a 20% increase in relative dose for the hot spot in the CTV and 10% increase in key critical structures when comparing min-MU limits of 0.0000 and 0.0060 with a fixed spot spacing of 4 mm. The DVHs of CTVs show min-MU limits of 0.0000 and 0.0010 produce similar plan quality and quality decreases as the min-MU limit increases beyond 0.0020. As spot spacing approaches 8 mm, degradation in plan quality is observed when no min-MU limit is imposed. Conclusions: Given a fixed spot spacing of ≤4 mm, plan quality decreases as min-MU increased beyond 0.0020. The effect of min-MU needs to be taken into consideration while planning proton therapy treatments.« less

  20. Diagnostic Accuracy of MRI Versus CT for the Evaluation of Acute Appendicitis in Children and Young Adults.

    PubMed

    Kinner, Sonja; Pickhardt, Perry J; Riedesel, Erica L; Gill, Kara G; Robbins, Jessica B; Kitchin, Douglas R; Ziemlewicz, Timothy J; Harringa, John B; Reeder, Scott B; Repplinger, Michael D

    2017-10-01

    Appendicitis is frequently diagnosed in the emergency department, most commonly using CT. The purpose of this study was to compare the diagnostic accuracy of contrast-enhanced MRI with that of contrast-enhanced CT for the diagnosis of appendicitis in adolescents when interpreted by abdominal radiologists and pediatric radiologists. Our study included a prospectively enrolled cohort of 48 patients (12-20 years old) with nontraumatic abdominal pain who underwent CT and MRI. Fellowship-trained abdominal and pediatric radiologists reviewed all CT and MRI studies in randomized order, blinded to patient outcome. Likelihood for appendicitis was rated on a 5-point scale (1, definitely not appendicitis; 5, definitely appendicitis) for CT, the unenhanced portion of the MRI, and the entire contrast-enhanced MRI study. ROC curves were generated and AUC compared for each scan type for all six readers and then stratified by radiologist type. Image test characteristics, interrater reliability, and reading times were compared. Sensitivity and specificity were 85.9% (95% CI, 76.2-92.7%) and 93.8% (95% CI, 89.7-96.7%) for unenhanced MRI, 93.6% (95% CI, 85.6-97.9%) and 94.3% (95% CI, 90.2-97%) for contrast-enhanced MRI, and 93.6% (95% CI, 85.6-97.9%) and 94.3% (95% CI, 90.2-97%) for CT. No difference was found in the diagnostic accuracy or interpretation time when comparing abdominal radiologists to pediatric radiologists (CT, 3.0 min vs 2.8 min; contrast-enhanced MRI, 2.4 min vs 1.8 min; unenhanced MRI, 1.5 min vs 2.3 min). Substantial agreement between abdominal and pediatric radiologists was seen for all methods (κ = 0.72-0.83). The diagnostic accuracy of MRI to diagnose appendicitis was very similar to CT. No statistically significant difference in accuracy was observed between imaging modality or radiologist subspecialty.

  1. Accuracy and reliability of different cone beam computed tomography (CBCT) devices for structural analysis of alveolar bone in comparison with multislice CT and micro-CT.

    PubMed

    Van Dessel, Jeroen; Nicolielo, Laura Ferreira Pinheiro; Huang, Yan; Coudyzer, Walter; Salmon, Benjamin; Lambrichts, Ivo; Jacobs, Reinhilde

    The aim of this study was to assess whether cone beam computed tomography (CBCT) may be used for clinically reliable alveolar bone quality assessment in comparison to its clinical alternatives, multislice computed tomography and the gold standard (micro-CT). Six dentate mandibular bone samples were scanned with seven CBCT devices (ProMax 3D Max, NewTom GiANO, Cranex 3D, 3D Accuitomo 170, Carestream 9300, Scanora 3D, I-CAT Next generation), one micro-CT scanner (SkyScan 1174) and one MSCT machine (Somatom Definition Flash) using two protocols (standard and high-resolution). MSCT and CBCT images were automatically spatially aligned on the micro-CT scan of the corresponding sample. A volume of interest was manually delineated on the micro-CT image and overlaid on the other scanning devices. Alveolar bone structures were automatically extracted using the adaptive thresholding algorithm. Based on the resulting binary images, an automatic 3D morphometric quantification was performed in a CT-Analyser (Bruker, Kontich, Belgium). The reliability and measurement errors were calculated for each modality compared to the gold standard micro-CT. Both MSCT and CBCT were associated with a clinically and statistically (P <0.05) significant measurement error. Bone quantity-related morphometric indices (bone volume fraction 8.41% min to 17.90% max, bone surface density -0.47 mm-1 min to 0.16 mm-1 max and trabecular thickness 0.15 mm min to 0.31 mm max) were significantly (P <0.05) overestimated, resulting in significantly (P <0.05) closer trabecular pores (total porosity percentage -8.41% min to -17.90% max and fractal dimension 0.08 min to 0.17 max) in all scanners compared to micro-CT. However, the structural pattern of the alveolar bone remained similar compared to that of the micro-CT for the ProMax 3D Max, NewTom GiANO, Cranex 3D, 3D Accuitomo 170 and Carestream 9300. On the other hand, the Scanora 3D, i-CAT Next Generation, standard and high-resolution MSCT displayed an overrated bone quantity and aberrant structural pattern compared to other scanning devices. The calculation of morphometric indices had an overall high reliability (intraclass correlation coefficient [ICC] 0.62 min to 0.99 max), except for the i-CAT Next Generation CBCT (ICC 0.26 min to 0.86 max) and standard resolution MSCT (ICC 0.10 min to 0.62 max). This study demonstrated that most CBCT machines may be able to quantitatively assess alveolar bone quality, with a level of accuracy and reliability that approaches micro-CT. One may therefore propose to extrapolate this to clinical CBCT imaging, certainly when there is a need for implant rehabilitation in dentate jaw bones. Conflict-of-interest statement: There is no conflict of interest to declare. Fellowship support was received from Research Foundation Flanders (FWO) from the Belgian government and from the Coordination for the Improvement of Higher Education Personnel (CAPES) programme, Science without Borders, from the Brazilian government.

  2. DSC and curing kinetics study of epoxy grouting diluted with furfural -acetone slurry

    NASA Astrophysics Data System (ADS)

    Yin, H.; Sun, D. W.; Li, B.; Liu, Y. T.; Ran, Q. P.; Liu, J. P.

    2016-07-01

    The use of furfural-acetone slurry as active diluents of Bisphenol-A epoxy resin (DGEBA) groutings has been studied by dynamic and non-isothermal DSC for the first time. Curing kinetics study was investigated by non-isothermal differential scanning calorimetries at different heating rates. Activation enery (Ea) was calculated based on Kissinger and Ozawa Methods, and the results showed that Ea increased from 58.87 to 71.13KJ/mol after the diluents were added. The furfural-acetone epoxy matrix could cure completely at the theoretical curing temperature of 365.8K and the curing time of 139mins, which were determined by the kinetic model parameters.

  3. Flat-Panel Cone-Beam Ct-Guided Radiofrequency Ablation of Very Small (≤1.5 cm) Liver Tumors: Technical Note on a Preliminary Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cazzato, Roberto Luigi, E-mail: r.cazzato@unicampus.it; Buy, Xavier, E-mail: x.buy@bordeaux.unicancer.fr; Alberti, Nicolas, E-mail: nicoalbertibdx@gmail.com

    2015-02-15

    PurposeThe aim of the present study was to investigate the technical feasibility of flat-panel cone-beam CT (CBCT)-guided radiofrequency ablation (RFA) of very small (<1.5 cm) liver tumors.Materials and MethodsPatients included were candidates for hepatic percutaneous RFA as they had single biopsy-proven hepatic tumors sized ≤1.5 cm and poorly defined on ultrasonography. Following apnea induction, unenhanced CBCT scans were acquired and used to deploy the RF electrode with the aid of a virtual navigation system. If the tumor was not clearly identified on the unenhanced CBCT scan, a right retrograde arterial femoral access was established to carry out hepatic angiography and localize themore » tumor. Patients’ lesions and procedural variables were recorded and analyzed.ResultsThree patients (2 male and 1 female), aged 68, 76, and 87 years were included; 3 lesions (2 hepato-cellular carcinoma and 1 metastasis from colorectal cancer) were treated. One patient required hepatic angiography. Cycles of apnea used to acquire CBCT images and to deploy the electrode lasted <120 s. Mean fluoroscopic time needed to deploy the electrode was 36.6 ± 5.7 min. Mean overall procedural time was 66.0 ± 22.9 min. No peri- or post-procedural complications were noted. No cases of incomplete ablation were noted at 1-month follow-up.ConclusionPercutaneous CBCT-guided liver RFA with or without arterial hepatic angiography is technically feasible.« less

  4. Characterization of Ag-porous silicon nanostructured layer formed by an electrochemical etching of p-type silicon surface for bio-application

    NASA Astrophysics Data System (ADS)

    Naddaf, M.; Al-Mariri, A.; Haj-Mhmoud, N.

    2017-06-01

    Nanostructured layers composed of silver-porous silicon (Ag-PS) have been formed by an electrochemical etching of p-type (1 1 1) silicon substrate in a AgNO3:HF:C2H5OH solution at different etching times (10 min-30 min). Scanning electron microscopy (SEM) and energy-dispersive x-ray spectroscopy (EDS) results reveal that the produced layers consist of Ag dendrites and a silicon-rich porous structure. The nanostructuring nature of the layer has been confirmed by spatial micro-Raman scattering and x-ray diffraction techniques. The Ag dendrites exhibit a surface-enhanced Raman scattering (SERS) spectrum, while the porous structure shows a typical PS Raman spectrum. Upon increasing the etching time, the average size of silicon nanocrystallite in the PS network decreases, while the average size of Ag nanocrystals is slightly affected. In addition, the immobilization of prokaryote Salmonella typhimurium DNA via physical adsorption onto the Ag-PS layer has been performed to demonstrate its efficiency as a platform for detection of biological molecules using SERS.

  5. Non-contrast enhanced MR venography using 3D fresh blood imaging (FBI): initial experience.

    PubMed

    Yokoyama, K; Nitatori, T; Inaoka, S; Takahara, T; Hachiya, J

    2001-01-01

    This study examined the efficacy of 3D-fresh blood imaging (FBI) in patients with venous disease in the iliac region to lower extremity. Fourteen patients with venous disease were examined [8 deep venous thrombosis (DVT) and 6 varix] by 3D-FBI and 2D-TOF MRA. All FBI images and 2D-TOF images were evaluated in terms of visualization of the disease and compared with conventional X-ray venography (CV). The total scan time of 3D-FBI ranged from 3 min 24 sec to 4 min 52 sec. 3D-FBI was positive in all 23 anatomical levels in which DVT was diagnosed by CV (100% sensitivity) as well as 2D-TOF. The delineation of collateral veins was superior or equal to that of 2D-TOF. 3D-FBI allowed depiction of varices in five of six cases; however, in one case, the evaluation was limited because the separation of arteries from veins was difficult. The 3D-FBI technique, which allows iliac to peripheral MR venography without contrast medium within a short acquisition time, is considered clinically useful.

  6. Rapid and nondestructive method for evaluation of embryo culture media using drop coating deposition Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Huang, Zufang; Sun, Yan; Wang, Jing; Du, Shengrong; Li, Yongzeng; Lin, Juqiang; Feng, Shangyuan; Lei, Jinping; Lin, Hongxin; Chen, Rong; Zeng, Haishan

    2013-12-01

    In this study, a rapid and simple method which combines drop coating deposition and Raman spectroscopy (DCDR) was developed to characterize the dry embryo culture media (ECM) droplet. We demonstrated that Raman spectra obtained from the droplet edge presented useful and characteristic signatures for protein and amino acids assessment. Using a different analytical method, scanning electron microscopy coupled with energy dispersive X-ray analysis, we further confirmed that Na, K, and Cl were mainly detected in the central area of the dry ECM droplet while sulphur, an indicative of the presence of macromolecules such as proteins, was mainly found at the periphery of the droplet. In addition, to reduce sample preparation time, different temperatures for drying the droplets were tested. The results showed that drying temperature at 50°C can effectively reduce the sample preparation time to 6 min (as compared to 50 min for drying at room temperature, ˜25°C) without inducing thermal damage to the proteins. This work demonstrated that DCDR has potential for rapid and reliable metabolomic profiling of ECM in clinical applications.

  7. Chemical Modification of Waste Cotton Linters for Oil Spill Cleanup Application

    NASA Astrophysics Data System (ADS)

    Chattopadhyay, Debapriya; Umrigar, Keval

    2017-12-01

    The possibility of use of waste cotton linters as oil sorbents by chemical modification such as acetylation and cyanoethylation was studied. The acetylation process was carried out in presence of acetic anhydride using either H2SO4 or HClO4 as catalyst. The acetylation treatment time was 30, 60 and 120 min and treatment temperature was room temperature, 50 and 70 °C. For cyanoethylation, the waste cotton linters were pre-treated with 2, 5 and 10% NaOH. The treatment temperature for cyanoethylation was room temperature, 50 and 70 °C and treatment time was 30, 60 and 120 min. Both the chemical modification processes were optimized on the basis of oil absorption capacity of the chemically modified cotton fibre with the help of MATLAB software. The modified samples were tested for its oleophilicity in terms of oil absorption capacity, oil retention capacity, oil recovery capacity, reusability of sample and water uptake and buoyancy as oil sorbent. Chemically modified fibres were characterized by Fourier transform infra red spectrophotometer, scanning electron microscope and degree of substitutions.

  8. Processes involved in the development of latent fingerprints using the cyanoacrylate fuming method.

    PubMed

    Lewis, L A; Smithwick, R W; Devault, G L; Bolinger, B; Lewis, S A

    2001-03-01

    Chemical processes involved in the development of latent fingerprints using the cyanoacrylate fuming method have been studied. Two major types of latent prints have been investigated-clean and oily prints. Scanning electron microscopy (SEM) has been used as a tool for determining the morphology of the polymer developed separately on clean and oily prints after cyanoacrylate fuming. A correlation between the chemical composition of an aged latent fingerprint, prior to development, and the quality of a developed fingerprint has been observed in the morphology. The moisture in the print prior to fuming has been found to be more important than the moisture in the air during fuming for the development of a useful latent print. In addition, the amount of time required to develop a high quality latent print has been found to be within 2 min. The cyanoacrylate polymerization process is extremely rapid. When heat is used to accelerate the fuming process, typically a period of 2 min is required to develop the print. The optimum development time depends upon the concentration of cyanoacrylate vapors within the enclosure.

  9. Photocatalytic degradation of an azo textile dye (C.I. Reactive Red 195 (3BF)) in aqueous solution over copper cobaltite nanocomposite coated on glass by Doctor Blade method

    NASA Astrophysics Data System (ADS)

    Habibi, Mohammad Hossein; Rezvani, Zoya

    2015-08-01

    The degradation of C.I. Reactive Red 195 (3BF) in aqueous solution using copper cobaltite nanocomposite coated on glass by Doctor Blade method was studied. Structural, optical and morphological properties of nanocomposite coatings were characterized by X-ray powder diffractometry (XRD), diffuse reflectance spectroscopy (DRS) and field emission scanning electron microscopy (FESEM). The nanoparticles exhibit a particle size of 31 nm, showing a good nanoscale crystalline morphology. The photocatalytic activity of copper cobaltite nanocomposite coated on glass was studied by performing the photocatalytic degradation of 3BF at different irradiation time. The effect of irradiation time on the degradation of 3BF was studied and the results showed that more than 85% of the 3BF was degraded in 45 min of irradiation. The pseudo-first-order kinetic models were used and the rate constants were evaluated with pseudo first order rate constants of 4.10 × 10-2 min-1. The main advantage of the photocatalyst coated on glass overcomes the difficulties in separation and recycle of photocatalyst suspensions.

  10. Electrochemical disinfection of simulated ballast water on PbO2/graphite felt electrode.

    PubMed

    Chen, Shuiping; Hu, Weidong; Hong, Jianxun; Sandoe, Steve

    2016-04-15

    A novel PbO2/graphite felt electrode was constructed by electrochemical deposition of PbO2 on graphite felt and characterized by X-ray powder diffraction (XRD) and scanning electron microscopy (SEM) analysis. The prepared electrode is a viable technology for inactivation of Escherichia coli, Enterococcus faecalis, and Artemia salina as indicator organisms in simulated ballast water treatment, which meets the International Maritime Organization (IMO) Regulation D-2. The effects of contact time and current density on inactivation were investigated. An increase in current density generally had a beneficial effect on the inactivation of the three species. E.faecalis and A.salina were more resistant to electrochemical disinfection than E. coli. The complete disinfection of E.coli was achieved in <8min at an applied current density of 253A/m(2). Complete inactivation of E. faecalis and A.salina was achieved at the same current density after 60 and 40min of contact time, respectively. A. salina inactivation follows first-order kinetics. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Performance evaluation of a high resolution dedicated breast PET scanner

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    García Hernández, Trinitat, E-mail: mtrinitat@eresa.com; Vicedo González, Aurora; Brualla González, Luis

    2016-05-15

    Purpose: Early stage breast cancers may not be visible on a whole-body PET scan. To overcome whole-body PET limitations, several dedicated breast positron emission tomography (DbPET) systems have emerged nowadays aiming to improve spatial resolution. In this work the authors evaluate the performance of a high resolution dedicated breast PET scanner (Mammi-PET, Oncovision). Methods: Global status, uniformity, sensitivity, energy, and spatial resolution were measured. Spheres of different sizes (2.5, 4, 5, and 6 mm diameter) and various 18 fluorodeoxyglucose ({sup 18}F-FDG) activity concentrations were randomly inserted in a gelatine breast phantom developed at our institution. Several lesion-to-background ratios (LBR) weremore » simulated, 5:1, 10:1, 20:1, 30:1, and 50:1. Images were reconstructed using different voxel sizes. The ability of experienced reporters to detect spheres was tested as a function of acquisition time, LBR, sphere size, and matrix reconstruction voxel size. For comparison, phantoms were scanned in the DbPET camera and in a whole body PET (WB-PET). Two patients who just underwent WB-PET/CT exams were imaged with the DbPET system and the images were compared. Results: The measured absolute peak sensitivity was 2.0%. The energy resolution was 24.0% ± 1%. The integral and differential uniformity were 10% and 6% in the total field of view (FOV) and 9% and 5% in the central FOV, respectively. The measured spatial resolution was 2.0, 1.9, and 1.7 mm in the radial, tangential, and axial directions. The system exhibited very good detectability for spheres ≥4 mm and LBR ≥10 with a sphere detection of 100% when acquisition time was set >3 min/bed. For LBR = 5 and acquisition time of 7 min the detectability was 100% for spheres of 6 mm and 75% for spheres of 5, 4, and 2.5 mm. Lesion WB-PET detectability was only comparable to the DbPET camera for lesion sizes ≥5 mm when acquisition time was >3 min and LBR > 10. Conclusions: The DbPET has a good performance for its clinical use and shows an improved resolution and lesion detectability of small lesions compared to WB-PET.« less

  12. Optimal time-point for 68Ga-PSMA-11 PET/CT imaging in assessment of prostate cancer: feasibility of sterile cold-kit tracer preparation?

    PubMed

    Beheshti, Mohsen; Paymani, Zeinab; Brilhante, Joana; Geinitz, Hans; Gehring, Daniela; Leopoldseder, Thomas; Wouters, Ludovic; Pirich, Christian; Loidl, Wolfgang; Langsteger, Werner

    2018-07-01

    In this prospective study, we evaluated the optimal time-point for 68 Ga-PSMA-11 PET/CT acquisition in the assessment of prostate cancer. We also examined, for the first time the feasibility of tracer production using a PSMA-11 sterile cold-kit in the clinical workflow of PET/CT centres. Fifty prostate cancer patients (25 staging, 25 biochemical recurrence) were enrolled in this study. All patients received an intravenous dose of 2.0 MBq/kg body weight 68 Ga-PSMA-11 prepared using a sterile cold kit (ANMI SA, Liege, Belgium), followed by an early (20 min after injection) semi-whole-body PET/CT scan and a standard-delay (100 min after injection) abdominopelvic PET/CT scan. The detection rates with 68 Ga-PSMA-11 were compared between the two acquisitions. The pattern of physiological background activity and tumour to background ratio were also analysed. The total preparation time was reduced to 5 min using the PSMA-11 sterile cold kit, which improved the final radionuclide activity by about 30% per single 68 Ge/ 68 Ga generator elution. Overall, 158 pathological lesions were analysed in 45 patients (90%) suggestive of malignancy on both (early and standard-delay) 68 Ga-PSMA PET/CT images. There was a significant (p < 0.001) increase in SUVmax on delayed images in suspicious prostates (11.6 ± 8.2 to 14.8 ± 1.0) and lymph nodes (LNs; 9.7 ± 5.9 to 12.3 ± 8.8), while bone lesions showed no significant increase (8.5 ± 5.6 to 9.2 ± 7.0, p = 0.188). However, the SUVmax of suspicious lesions on early images was adequate to support the criteria for correct interpretation (mean SUVmax 9.83 ± 6.7).In 26 of 157 lesions, but a decrease in SUV was seen, mostly in subcentimetre lesions in patients with multiple metastases. However, it did not affect the staging of the disease or patient management. The tumour to background ratio of primary prostate lesions and LNs showed a significant (p < 0.001) increase from the early to the standard-delay acquisition, but no significant increase was seen in bony lesions (p = 0.11). The PSMA-11 sterile cold kit seems to be feasible for use in routine clinical practice, and it has a shorter radionuclide preparation time and is less operator-dependent than the synthesizer-based production method. In addition, early 68 Ga-PSMA-11 PET/CT imaging seems to provide a detection rate comparable with that of standard-delay imaging. Furthermore, the shorter preparation time using the 68 Ga-PSMA-11 sterile cold kit and promising value of early PET/CT scanning could allow tailoring of imaging protocols which may reduce the costs and improve the time efficiency in PET/CT centres.

  13. Integrating respiratory gating into a megavoltage cone-beam CT system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang Jenghwa; Sillanpaa, Jussi; Ling, Clifton C.

    2006-07-15

    We have previously described a low-dose megavoltage cone beam computed tomography (MV CBCT) system capable of producing projection image using one beam pulse. In this study, we report on its integration with respiratory gating for gated radiotherapy. The respiratory gating system tracks a reflective marker on the patient's abdomen midway between the xiphoid and umbilicus, and disables radiation delivery when the marker position is outside predefined thresholds. We investigate two strategies for acquiring gated scans. In the continuous rotation-gated acquisition, the linear accelerator (LINAC) is set to the fixed x-ray mode and the gantry makes a 5 min, 360 deg.continuousmore » rotation, during which the gating system turns the radiation beam on and off, resulting in projection images with an uneven distribution of projection angles (e.g., in 70 arcs each covering 2 deg.). In the gated rotation-continuous acquisition, the LINAC is set to the dynamic arc mode, which suspends the gantry rotation when the gating system inhibits the beam, leading to a slightly longer (6-7 min) scan time, but yielding projection images with more evenly distributed projection angles (e.g., {approx}0.8 deg.between two consecutive projection angles). We have tested both data acquisition schemes on stationary (a contrast detail and a thoracic) phantoms and protocol lung patients. For stationary phantoms, a separate motion phantom not visible in the images is used to trigger the RPM system. Frame rate is adjusted so that approximately 450 images (13 MU) are acquired for each scan and three-dimensional tomographic images reconstructed using a Feldkamp filtered backprojection algorithm. The gated rotation-continuous acquisition yield reconstructions free of breathing artifacts. The tumor in parenchymal lung and normal tissues are easily discernible and the boundary between the diaphragm and the lung sharply defined. Contrast-to-noise ratio (CNR) is not degraded relative to nongated scans of stationary phantoms. The continuous rotation-gated acquisition scan also yields tomographic images with discernible anatomic features; however, streak artifacts are observed and CNR is reduced by approximately a factor of 4. In conclusion, we have successfully developed a gated MV CBCT system to verify the patient positioning for gated radiotherapy.« less

  14. Soft-copy sonography: cost reduction sensitivity analysis in a pediatric hospital.

    PubMed

    Don, S; Albertina, M J; Ammann, D

    1998-03-01

    Our objective was to determine whether interpreting sonograms of pediatric patients using soft-copy (computer workstation) instead of laser-printed film could reduce costs for a pediatric radiology department. We used theoretic models of growth to analyze costs. The costs of a sonographic picture archiving and communication system (three interface devices, two workstations, a network server, maintenance expenses, and storage media costs) were compared with the potential savings of eliminating film and increasing technologist efficiency or reducing the number of technologists. The model was based on historic trends and future capitation estimates that will reduce fee-for-service reimbursement. The effects of varying the study volume and reducing technologists' work hours were analyzed. By converting to soft-copy interpretation, we saved 6 min 32 sec per examination by eliminating film processing waiting time, thus reducing examination time from 30 min to 24 min. During an average day of 27 examinations, 176 min were saved. However, 33 min a day were spent retrieving prior studies from long-term storage; thus, 143 extra minutes a day were available for scanning. This improved efficiency could result in five more sonograms a day obtained by converting to soft-copy interpretation, using existing staff and equipment. Alternatively, five examinations a day would equate to one half of a full-time equivalent technologists position. Our analysis of costs considered that the hospital's anticipated growth of sonography and the depreciation of equipment during 5 years resulted in a savings of more than $606,000. Increasing the examinations by just 200 sonograms in the first year and no further growth resulted in a savings of more than $96,000. If the number of sonograms stayed constant, elimination of film printing alone resulted in a loss of approximately $157,000; reduction of one half of a full-time equivalent technologist's position would recuperate approximately $134,000 of that loss. Soft-copy sonography can save money through improved technologist efficiency, thereby increasing the number of sonograms obtained and revenue generated. If the number of sonograms does not increase, elimination of printing costs and reduction of staff technologists will not result in a savings.

  15. Characteristics of a ceramic-substrate x-ray diode and its application to computed tomography

    NASA Astrophysics Data System (ADS)

    Watanabe, Manabu; Sato, Eiichi; Kodama, Hajime; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Kusachi, Shinya; Sato, Shigehiro; Ogawa, Akira

    2013-09-01

    X-ray photon counting was performed using a silicon X-ray diode (Si-XD) at a tube current of 2.0 mA and tube voltages ranging from 50 to 70 kV. The Si-XD is a high-sensitivity Si photodiode selected for detecting X-ray photons, and Xray photons are directly detected using the Si-XD without a scintillator. Photocurrent from the diode is amplified using charge-sensitive and shaping amplifiers. To investigate the X-ray-electric conversion, we performed the event-pulseheight (EPH) analysis using a multichannel analyzer. Photon-counting computed tomography (PC-CT) is accomplished by repeated linear scans and rotations of an object, and projection curves of the object are obtained by the linear scan. The exposure time for obtaining a tomogram was 10 min at a scan step of 0.5 mm and a rotation step of 1.0°. In PC-CT at a tube voltage of 70 kV, the image contrast of iodine media fell with increasing lower-level voltage of the event pulse using a comparator.

  16. Unambiguous characterization of gunshot residue particles using scanning laser ablation and inductively coupled plasma-mass spectrometry.

    PubMed

    Abrego, Zuriñe; Ugarte, Ana; Unceta, Nora; Fernández-Isla, Alberto; Goicolea, M Aranzazu; Barrio, Ramón J

    2012-03-06

    A new method based on scanning laser ablation and inductively coupled plasma-mass spectrometry (LA-ICPMS) for the detection and identification of gunshot residue (GSR) particles from firearms discharges has been developed. Tape lifts were used to collect inorganic residues from skin surfaces. The laser ablation pattern and ICPMS conditions were optimized for the detection of metals present in GSR, such as (121)Sb, (137)Ba, and (208)Pb. Other isotopes ((27)Al, (29)Si, (31)P, (33)S, (35)Cl, (39)K, (44)Ca, (57)Fe, (60)Ni, (63)Cu, (66)Zn, and (118)Sn) were monitored during the ICPMS analyses to obtain additional information to possibly classify the GSR particles as either characteristic of GSR or consistent with GSR. In experiments with real samples, different firearms, calibers, and ammunitions were used. The performed method evaluation confirms that the developed methodology can be used as an alternative to the standard scanning electron microscopy-energy dispersive spectroscopy (SEM-EDS) technique, with the significant advantage of drastically reducing the analysis time to less than 66 min.

  17. Disinfection of Streptococcus mutans biofilm by a non-thermal atmospheric plasma brush

    NASA Astrophysics Data System (ADS)

    Hong, Qing; Dong, Xiaoqing; Chen, Meng; Xu, Yuanxi; Sun, Hongmin; Hong, Liang; Wang, Yong; Yu, Qingsong

    2016-07-01

    This study investigated the argon plasma treatment effect on disinfecting dental biofilm by using an atmospheric pressure plasma brush. Streptococcus mutans biofilms were developed for 3 days on the surfaces of hydroxyapatite (HA) discs, which were used to simulate human tooth enamel. After plasma treatment, cell viability in the S. mutans biofilms was characterized by using 3-(4,5-dimethylazol-2-yl)-2,5-diphenyl-2H-tetrazolium bromide (MTT) assay and confocal laser scanning microscopy (CLSM). Compared with the untreated control group, about 90% bacterial reduction in the biofilms was observed after 1 min plasma treatment. Scanning electron microscopy (SEM) examination indicated severe cell damages occurred on the top surface of the plasma treated biofilms. Confocal laser scanning microscopy (CLSM) showed that plasma treatment was effective as deep as 20 µm into the biofilms. When combined with antibiotic treatment using 0.2% chlorhexidine digluconate solution, the plasma treatment became more effective and over 96% bacterial reduction was observed with 1 min plasma treatment.

  18. Kinetics of the Tau PET Tracer 18F-AV-1451 (T807) in Subjects with Normal Cognitive Function, Mild Cognitive Impairment, and Alzheimer Disease.

    PubMed

    Shcherbinin, Sergey; Schwarz, Adam J; Joshi, Abhinay; Navitsky, Michael; Flitter, Matthew; Shankle, William R; Devous, Michael D; Mintun, Mark A

    2016-10-01

    We report kinetic modeling results of dynamic acquisition data from 0 to 100 min after injection with the tau PET tracer 18 F-AV-1451 in 19 subjects. Subjects were clinically diagnosed as 4 young cognitively normal, 5 old cognitively normal, 5 mild cognitive impairment, and 5 Alzheimer disease (AD). Kinetic modeling was performed using Logan graphical analysis with the cerebellum crus as a reference region. Voxelwise binding potential ([Formula: see text]) and SUV ratio ([Formula: see text]) images were compared. In AD subjects, slower and spatially nonuniform clearance from cortical regions was observed as compared with the controls, which led to focal uptake and elevated retention in the imaging data from 80 to 100 min after injection. BP from the dynamic data from 0 to 100 min correlated strongly (R 2 > 0.86) with corresponding regional [Formula: see text] values. In the putamen, the observed kinetics (positive [Formula: see text] at the tracer delivery stage and plateauing time-SUVR curves for all diagnostic categories) may suggest either additional off-target binding or a second binding site with different kinetics. The kinetics of the 18 F-AV-1451 tracer in cortical areas, as examined in this small group of subjects, differed by diagnostic stage. A delayed 80- to 100-min scan provided a reasonable substitute for a dynamic 0- to 100-min acquisition for cortical regions although other windows (e.g., 75-105 min) may be useful to evaluate. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  19. Synthesis and properties of Ag/ZnO/g-C3N4 ternary micro/nano composites by microwave-assisted method

    NASA Astrophysics Data System (ADS)

    Zhang, Zijie; Li, Xuexue; Chen, Haitao; Shao, Gang; Zhang, Rui; Lu, Hongxia

    2018-01-01

    Ag/ZnO/g-C3N4 ternary micro/nanocomposites, as novel visible-light-driven photocatalysts, were prepared by a simple and convenient microwave-assisted method. The resulting ternary structure micro/nano composites were characterized by x-ray diffraction, x-ray photoelectron spectroscopy, scanning electron microscopy, ultraviolet-visible diffuse reflectance spectroscopy and infrared radiation techniques to examine its phase structure, valence state, morphological, thermal and optical properties. Well crystallized Ag/ZnO/g-C3N4 ternary micro/nano composites were synthesized under microwave-radiation for 15 min with the output of 240 W. Further experiments indicated Ag(5.0mol%)/ZnO/g-C3N4 photocatalyst in degradation of methylene blue exhibited an outstanding photocatalytic activity and its reaction rate constant (k, 0.0084 min-1) is 7.5, 2.4 2.9 and 3.5 times higher than that of monolithic ZnO (k, 0.0011 min-1), ZnO/g-C3N4(k, 0.0035 min-1), Ag(5 mol%)/ZnO(k, 0.0029 min-1) and Ag(5mol%)/g-C3N4 (k, 0.0024 min-1) respectively. Finally, a possible photocatalytic mechanism of Ag/ZnO/g-C3N4 photocatalyst in degradation process was proposed. This work provides a feasible strategy to synthesize an efficient ZnO-based photocatalyst which combines structure and properties of different dimensional components and made this ternary system an exciting candidate for sunlight-driven photocatalytic water treatment.

  20. Kinetics and mechanism of bacterial inactivation by ultrasound waves and sonoprotective effect of milk components.

    PubMed

    Gera, N; Doores, S

    2011-03-01

    Inactivation of Escherichia coli and Listeria monocytogenes were investigated in buffer and milk upon treatment with ultrasound waves (USW). In addition, sonoprotective effect of milk components and ultrasound-induced changes in bacterial cells were investigated using scanning electron microscopy (SEM). Bacterial cells were added to phosphate buffer, whole milk, skim milk, or simulated milk ultrafiltrate (SMUF). To determine the sonoprotective effect of milk components, lactose (5%), casein (3%), or β lactoglobulin (0.3%) was added to SMUF. Samples were sonicated with 24 kHz pulse USW while maintaining the system temperature between 30 to 35 °C. Aliquots were drawn at set times during sonication and bacteria were enumerated by surface plating appropriate dilutions on selective and nonselective media plates. Escherichia coli exhibited significantly higher D values in whole (2.43 min) and skim milk (2.41 min) than phosphate buffer (2.19 min). Listeria monocytogenes also showed higher D values in whole (9.31 min) and skim milk (8.61 min) compared to phosphate buffer (7.63 min). Data suggest that milk exerts a sonoprotective effect on these bacteria. Escherichia coli exhibited a log-linear inactivation kinetics followed by tailing whereas L. monocytogenes showed 1st-order kinetics throughout. Among the milk components tested, presence of lactose in SMUF resulted in significantly higher D values than SMUF for both organisms suggesting that lactose was exerting a protective effect on bacteria. SEM images showed that USW caused mechanical damage to the cell wall and cell membrane of bacteria leading to their inactivation.

  1. Spatial and Temporal Patterns of Biocide Action against Staphylococcus epidermidis Biofilms▿ ‡

    PubMed Central

    Davison, William M.; Pitts, Betsey; Stewart, Philip S.

    2010-01-01

    The dynamic antimicrobial action of chlorine, a quaternary ammonium compound, glutaraldehyde, and nisin within biofilm cell clusters of Staphylococcus epidermidis was investigated using time-lapse confocal scanning laser microscopy. The technique allowed for the simultaneous imaging of changes in biofilm structure and disruption of cellular membrane integrity through the loss of an unbound fluorophore loaded into bacterial cells prior to antimicrobial challenge. Each of the four antimicrobial agents produced distinct spatial and temporal patterns of fluorescence loss. The antimicrobial action of chlorine was localized around the periphery of biofilm cell clusters. Chlorine was the only antimicrobial agent that caused any biofilm removal. Treatment with the quaternary ammonium compound caused membrane permeabilization that started at the periphery of cell clusters, then migrated steadily inward. A secondary pattern superimposed on the penetration dynamic suggested a subpopulation of less-susceptible cells. These bacteria lost fluorescence much more slowly than the majority of the population. Nisin caused a rapid and uniform loss of green fluorescence from all parts of the biofilm without any removal of biofilm. Glutaraldehyde caused no biofilm removal and also no loss of membrane integrity. Measurements of biocide penetration and action time at the center of cell clusters yielded 46 min for 10 mg liter−1 chlorine, 21 min for 50 mg liter−1 chlorine, 25 min for the quaternary ammonium compound, and 4 min for nisin. These results underscore the distinction between biofilm removal and killing and reinforce the critical role of biocide reactivity in determining the rate of biofilm penetration. PMID:20457816

  2. Sonophotocatalytic degradation of trypan blue and vesuvine dyes in the presence of blue light active photocatalyst of Ag3PO4/Bi2S3-HKUST-1-MOF: Central composite optimization and synergistic effect study.

    PubMed

    Mosleh, S; Rahimi, M R; Ghaedi, M; Dashtian, K

    2016-09-01

    An efficient simultaneous sonophotocatalytic degradation of trypan blue (TB) and vesuvine (VS) using Ag3PO4/Bi2S3-HKUST-1-MOF as a novel visible light active photocatalyst was carried out successfully in a continuous flow-loop reactor equipped to blue LED light. Ag3PO4/Bi2S3-HKUST-1-MOF with activation ability under blue light illumination was synthesized and characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray (EDX), photoluminescence (PL) and diffuse reflectance spectra (DRS). The effect of operational parameters such as the initial TB and VS concentration (5-45mg/L), flow rate (30-110mL/min), irradiation and sonication time (10-30min), pH (3-11) and photocatalyst dosage (0.15-0.35g/L) has been investigated and optimized using central composite design (CCD) combined with desirability function (DF). Maximum sonophotodegradation percentage (98.44% and 99.36% for TB and VS, respectively) was found at optimum condition set as: 25mg/L of each dye, 70mL/min of solution flow rate, 25min of irradiation and sonication time, pH 6 and 0.25g/L of photocatalyst dosage. At optimum conditions, synergistic index value was obtained 2.53 that indicated the hybrid systems including ultrasound irradiation and photocatalysis have higher efficiency compared with sum of the individual processes. Copyright © 2016. Published by Elsevier B.V.

  3. Diagnostic digital cytopathology: Are we ready yet?

    PubMed Central

    House, Jarret C.; Henderson-Jackson, Evita B.; Johnson, Joseph O.; Lloyd, Mark C.; Dhillon, Jasreman; Ahmad, Nazeel; Hakam, Ardeshir; Khalbuss, Walid E.; Leon, Marino E.; Chhieng, David; Zhang, Xiaohui; Centeno, Barbara A.; Bui, Marilyn M.

    2013-01-01

    Background: The cytology literature relating to diagnostic accuracy using whole slide imaging is scarce. We studied the diagnostic concordance between glass and digital slides among diagnosticians with different profiles to assess the readiness of adopting digital cytology in routine practice. Materials and Methods: This cohort consisted of 22 de-identified previously screened and diagnosed cases, including non-gynecological and gynecological slides using standard preparations. Glass slides were digitalized using Aperio ScanScope XT (×20 and ×40). Cytopathologists with (3) and without (3) digital experience, cytotechnologists (4) and senior pathology residents (2) diagnosed the digital slides independently first and recorded the results. Glass slides were read and recorded separately 1-3 days later. Accuracy of diagnosis, time to diagnosis and diagnostician's profile were analyzed. Results: Among 22 case pairs and four study groups, correct diagnosis (93% vs. 86%) was established using glass versus digital slides. Both methods more (>95%) accurately diagnosed positive cases than negatives. Cytopathologists with no digital experience were the most accurate in digital diagnosis, even the senior members. Cytotechnologists had the fastest diagnosis time (3 min/digital vs. 1.7 min/glass), but not the best accuracy. Digital time was 1.5 min longer than glass-slide time/per case for cytopathologists and cytotechnologists. Senior pathology residents were slower and less accurate with both methods. Cytopathologists with digital experience ranked 2nd fastest in time, yet last in accuracy for digital slides. Conclusions: There was good overall diagnostic agreement between the digital whole-slide images and glass slides. Although glass slide diagnosis was more accurate and faster, the results of technologists and pathologists with no digital cytology experience suggest that solid diagnostic ability is a strong indicator for readiness of digital adoption. PMID:24392242

  4. Re-designing scanning to reduce learning demands: the performance of typically developing 2-year-olds.

    PubMed

    McCarthy, John; Light, Janice; Drager, Kathryn; McNaughton, David; Grodzicki, Laura; Jones, Jonathan; Panek, Elizabeth; Parkin, Elizabeth

    2006-12-01

    Children with severe motor impairments who cannot use direct selection are typically introduced to scanning as a means of accessing assistive technology. Unfortunately, it is difficult for young children to learn to scan because the design of current scanning techniques does not always make explicit the offer of items from the selection array; furthermore, it does not provide explicit feedback after activation of the switch to select the target item. In the current study, scanning was redesigned to reduce learning demands by making both the offer of items and the feedback upon selection more explicit through the use of animation realized through HTML and speech output with appropriate intonation. Twenty typically developing 2-year-olds without disabilities were randomly assigned to use either traditional scanning or enhanced scanning to select target items from an array of three items. The 2-year-olds did not learn to use traditional scanning across three sessions. Their performance in Session 3 did not differ from that in Session 1; they did not exceed chance levels of accuracy in either session (mean accuracy of 20% for Sessions 1 and 3). In contrast, the children in the enhanced scanning condition demonstrated improvements in accuracy across the three 10-20-min sessions (mean accuracies of 22 and 48% for Sessions 1 and 3, respectively). There were no reliable differences between the children's performances with the two scanning techniques for Session 1; however, by Session 3, the children were more than twice as accurate using the enhanced scanning technique compared to the traditional design. Results suggest that by redesigning scanning, we may be able to reduce some of the learning demands and thereby reduce some of the instructional time required for children to attain mastery. Clinical implications, limitations, and directions for future research and development are discussed.

  5. Brain SPECT scans in students with specific learning disability: Preliminary results.

    PubMed

    Karande, S; Deshmukh, N; Rangarajan, V; Agrawal, A; Sholapurwala, R

    2018-06-08

    Brain single-photon emission computed tomography (SPECT) assesses brain function through measurement of regional cerebral blood flow. This study was conducted to assess whether students with newly diagnosed specific learning disability (SpLD) show any abnormalities in cerebral cortex perfusion. Cross-sectional single-arm pilot study in two tertiary care hospitals. Nine students with SpLD were enrolled. Brain SPECT scan was done twice in each student. For the first or "baseline" scan, the student was first made to sit with eyes open in a quiet, dimly lit room for a period of 30-40 min and then injected intravenously with 20 mCi of 99mTc-ECD. An hour later, "baseline scan" was conducted. After a minimum gap of 4 days, a second or "test scan" was conducted, wherein the student performed an age-appropriate curriculum-based test for a period of 30-40 min to activate the areas in central nervous system related to learning before being injected with 20 mCi of 99mTc-ECD. Cerebral cortex perfusion at rest and after activation in each student was compared qualitatively by visual analysis and quantitatively using NeuroGam TM software. Visual analysis showed reduction in regional blood flow in temporoparietal areas in both "baseline" and "test" scans. However, when normalization was attempted and comparison done by Talairach analysis using NeuroGam software, no statistically significant change in regional perfusion in temporoparietal areas was appreciated. Brain SPECT scan may serve as a robust tool to identify changes in regional brain perfusion in students with SpLD.

  6. Inactivation of Cronobacter malonaticus cells and inhibition of its biofilm formation exposed to hydrogen peroxide stress.

    PubMed

    Ye, Yingwang; Zhang, Maofeng; Jiao, Rui; Ling, Na; Zhang, Xiyan; Tong, Liaowang; Zeng, Haiyang; Zhang, Jumei; Wu, Qingping

    2018-01-01

    Presence of Cronobacter malonaticus in powdered infant formula (PIF) poses a high risk to infant and public health. Cronobacter malonaticus has been widely distributed in food and food processing environments, and the true origin of C. malonaticus in PIF is poorly understood. Control and prevention of C. malonaticus is necessary for achieving microbial safety of PIF. However, little information about decontamination of C. malonaticus is available. In this study, effects of hydrogen peroxide on inactivation and morphological changes of C. malonaticus cells were determined. Furthermore, inhibitory effects of H 2 O 2 on biofilm formation in C. malonaticus were also performed. Results indicated that H 2 O 2 could completely inactivate C. malonaticus in sterile water with 0.06% H 2 O 2 for 25 min, 0.08% H 2 O 2 for 15 min, and 0.10% for 10 min, respectively, whereas the survival rates of C. malonaticus in tryptic soy broth medium significantly increased with the same treatment time and concentration of H 2 O 2 . In addition, morphological changes of C. malonaticus cells, including cell shrinkage, disruption of cells, cell intercession, and leakage of intercellular material in sterile water after H 2 O 2 treatment, were more predominant than those in tryptic soy broth. Finally, significant reduction in biofilm formation by H 2 O 2 was found using crystal violet staining, scanning electron microscopy, and confocal laser scanning microscopy detection compared with control samples. This is the first report to determine the effects of H 2 O 2 on C. malonaticus cells and biofilm formation. The findings provided valuable information for practical application of H 2 O 2 for decontamination of C. malonaticus in dairy processing. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  7. Longitudinal observation of [11C]4DST uptake in turpentine-induced inflammatory tissue.

    PubMed

    Toyohara, Jun; Sakata, Muneyuki; Oda, Keiichi; Ishii, Kenji; Ishiwata, Kiichi

    2013-02-01

    Longitudinal changes of 4'-[methyl-(11)C]thiothymidine ([(11)C]4DST) uptake were evaluated in turpentine-induced inflammation. Turpentine (0.1 ml) was injected intramuscularly into the right hind leg of male Wistar rats. Longitudinal [(11)C]4DST uptake was evaluated by the tissue dissection method at 1, 2, 4, 7, and 14 days after turpentine injection (n=5). The tumor selectivity index was calculated using the previously published biodistribution data in C6 glioma-bearing rats. Dynamic PET scan was performed on day 4 when maximum [(11)C]4DST uptake was observed during the longitudinal study. Histopathological analysis and Ki-67 immunostaining were also performed. The uptake of [(11)C]4DST in inflammatory tissue was significantly increased on days 2-4 after turpentine injection, and then decreased. On day 14, tracer uptake returned to the day 1 level. The maximum SUV of inflamed muscle was 0.6 and was 3 times higher than that of the contralateral healthy muscle on days 2-4 after turpentine injection. However, tumor selectivity index remains very high (>10) because of the low inflammation uptake. A dynamic PET scan showed that the radioactivity in inflammatory tissues peaked at 5 min after [(11)C]4DST injection, and then washed out until 20 min. At intervals >20 min, radioactivity levels were constant and double that of healthy muscle. The changes in Ki-67 index were paralleled with those of [(11)C]4DST uptake, indicating cell proliferation-dependent uptake of [(11)C]4DST in inflammatory tissues. In our animal model, low but significant levels of [(11)C]4DST uptake were observed in subacute inflammation. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Evaluation of the bleached human enamel by Scanning Electron Microscopy.

    PubMed

    Miranda, Carolina Baptista; Pagani, Clovis; Benetti, Ana Raquel; Matuda, Fábio da Silva

    2005-06-01

    Since bleaching has become a popular procedure, the effect of peroxides on dental hard tissues is of great interest in research. The aim of this in vitro study was to perform a qualitative analysis of the human enamel after the application of in-office bleaching agents, using Scanning Electron Microscopy (SEM). Twenty intact human third molars extracted for orthodontic reasons were randomly divided into four groups (n=5) treated as follows: G1- storage in artificial saliva (control group); G2- four 30-minute applications of 35% carbamide peroxide (total exposure: 2h); G3- four 2-hour exposures to 35% carbamide peroxide (total exposure: 8h); G4- two applications of 35% hydrogen peroxide, which was light-activated with halogen lamp at 700mW/cm² during 7min and remained in contact with enamel for 20min (total exposure: 40min). All bleaching treatments adopted in this study followed the application protocols advised by manufacturers. Evaluation of groups submitted to 35% carbamide peroxide was carried out after two time intervals (30 minutes and 2 hours per session), following the extreme situations recommended by the manufacturer. Specimens were prepared for SEM analysis performing gold sputter coating under vacuum and were examined using 15kV at 500x and 2000x magnification. Morphological alterations on the enamel surface were similarly detected after bleaching with either 35% carbamide peroxide or 35% hydrogen peroxide. Surface porosities were characteristic of an erosive process that took place on human enamel. Depression areas, including the formation of craters, and exposure of enamel rods could also be detected. Bleaching effects on enamel morphology were randomly distributed throughout enamel surface and various degrees of enamel damage could be noticed. In-office bleaching materials may adversely affect enamel morphology and therefore should be used with caution.

  9. Repeatability of Quantitative Whole-Body 18F-FDG PET/CT Uptake Measures as Function of Uptake Interval and Lesion Selection in Non-Small Cell Lung Cancer Patients.

    PubMed

    Kramer, Gerbrand Maria; Frings, Virginie; Hoetjes, Nikie; Hoekstra, Otto S; Smit, Egbert F; de Langen, Adrianus Johannes; Boellaard, Ronald

    2016-09-01

    Change in (18)F-FDG uptake may predict response to anticancer treatment. The PERCIST suggest a threshold of 30% change in SUV to define partial response and progressive disease. Evidence underlying these thresholds consists of mixed stand-alone PET and PET/CT data with variable uptake intervals and no consensus on the number of lesions to be assessed. Additionally, there is increasing interest in alternative (18)F-FDG uptake measures such as metabolically active tumor volume and total lesion glycolysis (TLG). The aim of this study was to comprehensively investigate the repeatability of various quantitative whole-body (18)F-FDG metrics in non-small cell lung cancer (NSCLC) patients as a function of tracer uptake interval and lesion selection strategies. Eleven NSCLC patients, with at least 1 intrathoracic lesion 3 cm or greater, underwent double baseline whole-body (18)F-FDG PET/CT scans at 60 and 90 min after injection within 3 d. All (18)F-FDG-avid tumors were delineated with an 50% threshold of SUVpeak adapted for local background. SUVmax, SUVmean, SUVpeak, TLG, metabolically active tumor volume, and tumor-to-blood and -liver ratios were evaluated, as well as the influence of lesion selection and 2 methods for correction of uptake time differences. The best repeatability was found using the SUV metrics of the averaged PERCIST target lesions (repeatability coefficients < 10%). The correlation between test and retest scans was strong for all uptake measures at either uptake interval (intraclass correlation coefficient > 0.97 and R(2) > 0.98). There were no significant differences in repeatability between data obtained 60 and 90 min after injection. When only PERCIST-defined target lesions were included (n = 34), repeatability improved for all uptake values. Normalization to liver or blood uptake or glucose correction did not improve repeatability. However, after correction for uptake time the correlation of SUV measures and TLG between the 60- and 90-min data significantly improved without affecting test-retest performance. This study suggests that a 15% change of SUVmean/SUVpeak at 60 min after injection can be used to assess response in advanced NSCLC patients if up to 5 PERCIST target lesions are assessed. Lower thresholds could be used in averaged PERCIST target lesions (<10%). © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  10. Cryo-scanning electron microscopy discloses differences in dehydration of frozen boar semen stored in large containers.

    PubMed

    Ekwall, H

    2009-02-01

    In general, freezing in flat plastic polyethylene terephthalate (PET) bags (FlatPacks) at 50 degrees C/min gives better post-thaw viability, in terms of sperm motility and membrane integrity, than does freezing in plastic maxi-straws, probably owing to differences in cryobiology. To test the hypothesis that this better survival post-thaw relates to the degree of sperm dehydration during freezing, the present study investigated the structure of boar semen in a frozen state using cryo-scanning electron microscopy (cryo-SEM) to compare two different packages (FlatPacks and maxi-straws) for single artificial insemination (AI) doses, and three different freezing rates. The semen was split-sample frozen in maxi-straws or FlatPacks (both holding 5 ml) using 3% glycerol as cryoprotectant. Three freezing rates were applied from -5 degrees C to -100 degrees C, namely 2 degrees C/min, 50 degrees C/min and 1200 degrees C/min, the lattermost by plunging the samples into liquid nitrogen (LN(2)). The samples were thereafter fractured into LN(2) and larger areas of extra-cellular, unbound frozen water ('ice lakes') were measured to determine the degree of dehydration of the spermatozoa. These areas decreased in size with an increase in cooling rate, the differences in size being more dramatic for maxi-straws than for FlatPacks. Size of ice lakes was also influenced by location within package in relation to cooling rate, the central values being always smaller in maxi-straws than in Flatpacks (p < 0.05 at 2 degrees C/min and 50 degrees C/min) but not at 1200 degrees C/min, which suggested the FlatPack allows for more homogenous freezing of boar semen.

  11. [Preparation and in vitro dissolution of magnolol solid dispersion].

    PubMed

    Tang, Lan; Qiu, Shuai-Bo; Wu, Lan; Lv, Long-Fei; Lv, Hui-Xia; Shan, Wei-Guang

    2016-02-01

    In this study, solid dispersion system of magnolol in croscarmellose sodium was prepared by using the solvent evaporation method, in order to increase the drug dissolution. And its dissolution behavior, stability and physical characteristics were studied. The solid dispersion was prepared with magnolol and croscarmellose sodium, with the proportion of 1∶5, the in vitro dissolution of magnolol solid dispersion was up to 80.66% at 120 min, which was 6.9 times of magnolol. The results of DSC (differential scanning calorimetry), IR (infra-red) spectrum and SEM (scanning electron microscopy) showed that magnolol existed in solid dispersion in an amorphous form. After an accelerated stability test for six months, the drug dissolution and content in magnolol solid dispersion showed no significant change. So the solid dispersion prepared with croscarmellose sodium as the carrier can remarkably improve the stability and dissolution of magnolol. Copyright© by the Chinese Pharmaceutical Association.

  12. Kinetic filtering of [18F]Fluorothymidine in positron emission tomography studies

    NASA Astrophysics Data System (ADS)

    Gray, Katherine R.; Contractor, Kaiyumars B.; Kenny, Laura M.; Al-Nahhas, Adil; Shousha, Sami; Stebbing, Justin; Wasan, Harpreet S.; Coombes, R. Charles; Aboagye, Eric O.; Turkheimer, Federico E.; Rosso, Lula

    2010-02-01

    [18F]Fluorothymidine (FLT) is a cell proliferation marker that undergoes predominantly hepatic metabolism and therefore shows a high level of accumulation in the liver, as well as in rapidly proliferating tumours. Furthermore, the tracer's uptake is substantial in other organs including the heart. We present a nonlinear kinetic filtering technique which enhances the visualization of tumours imaged with FLT positron emission tomography (FLT-PET). A classification algorithm to isolate cancerous tissue from healthy organs was developed and validated using 29 scan data from patients with locally advanced or metastatic breast cancer. A large reduction in signal from the liver and heart of 80% was observed following application of the kinetic filter, whilst the majority of signal from both primary tumours and metastases was retained. A scan acquisition time of 60 min has been shown to be sufficient to obtain the necessary kinetic data. The algorithm extends utility of FLT-PET imaging in oncology research.

  13. Preclinical Evaluation of 18F-JNJ64349311, a Novel PET Tracer for Tau Imaging.

    PubMed

    Declercq, Lieven; Rombouts, Frederik; Koole, Michel; Fierens, Katleen; Mariën, Jonas; Langlois, Xavier; Andrés, José Ignacio; Schmidt, Mark; Macdonald, Gregor; Moechars, Diederik; Vanduffel, Wim; Tousseyn, Thomas; Vandenberghe, Rik; Van Laere, Koen; Verbruggen, Alfons; Bormans, Guy

    2017-06-01

    In this study, we have synthesized and evaluated 18 F-JNJ64349311, a tracer with high affinity for aggregated tau (inhibition constant value, 8 nM) and high (≥500×) in vitro selectivity for tau over β-amyloid, in comparison with the benchmark compound 18 F-AV1451 ( 18 F-T807) in mice, rats, and a rhesus monkey. Methods: In vitro binding characteristics were determined for Alzheimer's disease, progressive supranuclear palsy, and corticobasal degeneration patient brain tissue slices using autoradiography studies. Ex vivo biodistribution studies were performed in mice. Radiometabolites were quantified in the brain and plasma of mice and in the plasma of a rhesus monkey using high-performance liquid chromatography. Dynamic small-animal PET studies were performed in rats and a rhesus monkey to evaluate tracer pharmacokinetics in the brain. Results: Mouse biodistribution studies showed moderate initial brain uptake and rapid brain washout. Radiometabolite analyses after injection of 18 F-JNJ64349311 in mice showed the presence of a polar radiometabolite in plasma, but not in the brain. Semiquantitative autoradiography studies on postmortem tissue sections of human Alzheimer's disease brains showed highly displaceable binding to tau-rich regions. No specific binding was, however, found on human progressive supranuclear palsy and corticobasal degeneration brain slices. Small-animal PET scans of Wistar rats revealed moderate initial brain uptake (SUV, ∼1.5 at 1 min after injection) and rapid brain washout. Gradual bone uptake was, however, also observed. Blocking and displacement did not affect brain time-activity curves, suggesting no off-target specific binding of the tracer in the healthy rat brain. A small-animal PET scan of a rhesus monkey revealed moderate initial brain uptake (SUV, 1.9 at 1 min after injection) with a rapid washout. In the monkey, no bone uptake was detected during the 120-min scan. Conclusion: This biologic evaluation suggests that 18 F-JNJ64349311 is a promising tau PET tracer candidate, with a favorable pharmacokinetic profile, as compared with 18 F-AV1451. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  14. Renal cortical and medullary blood flow responses to altered NO availability in humans.

    PubMed

    Damkjær, Mads; Vafaee, Manoucher; Møller, Michael L; Braad, Poul Erik; Petersen, Henrik; Høilund-Carlsen, Poul Flemming; Bie, Peter

    2010-12-01

    The objective of this study was to quantify regional renal blood flow in humans. In nine young volunteers on a controlled diet, the lower abdomen was CT-scanned, and regional renal blood flow was determined by positron emission tomography (PET) scanning using H(2)(15)O as tracer. Measurements were performed at baseline, during constant intravenous infusion of nitric oxide (NO) donor glyceryl nitrate and after intravenous injection of NO synthase inhibitor N(ω)-monomethyl-L-arginine (L-NMMA). Using the CT image, the kidney pole areas were delineated as volumes of interest (VOI). In the data analysis, tissue layers with a thickness of one voxel were eliminated stepwise from the external surface of the VOI (voxel peeling), and the blood flow subsequently was determined in each new, reduced VOI. Blood flow in the shrinking VOIs decreased as the number of cycles of voxel peeling increased. After 4-5 cycles, blood flow was not reduced further by additional voxel peeling. This volume-insensitive flow was measured to be 2.30 ± 0.17 ml·g tissue(-1)·min(-1) during the control period; it increased during infusion of glyceryl nitrate to 2.97 ± 0.18 ml·g tissue(-1)·min(-1) (P < 0.05) and decreased after L-NMMA injection to 1.57 ± 0.17 ml·g tissue(-1)·min(-1) (P < 0.05). Cortical blood flow was 4.67 ± 0.31 ml·g tissue(-1)·min(-1) during control, unchanged by glyceryl nitrate, and decreased after L-NMMA [3.48 ± 0.23 ml·(g·min)(-1), P < 0.05]. PET/CT scanning allows identification of a renal medullary region in which the measured blood flow is 1) low, 2) independent of reduction in the VOI, and 3) reactive to changes in systemic NO supply. The technique seems to provide indices of renal medullary blood flow in humans.

  15. Myocardial Fat Quantification in Humans: Evaluation by Two-Point Water-Fat Imaging and Localized Proton Spectroscopy

    PubMed Central

    Liu, Chia-Ying; Redheuil, Alban; Ouwerkerk, Ronald; Lima, Joao A. C.; Bluemke, David A.

    2011-01-01

    Proton MR spectroscopy (1H-MRS) has been used for in vivo quantification of intracellular triglycerides within the sarcolemma. The purpose of this study was to assess whether breath-hold dual-echo in- and out-of-phase MRI at 3.0 T can quantify the fat content of the myocardium. Biases, including T1, T2∗, and noise, that confound the calculation of the fat fraction were carefully corrected. Thirty-four of 46 participants had both MRI and MRS data. The fat fractions from MRI showed a strong correlation with fat fractions from MRS (r = 0.78; P < 0.05). The mean myocardial fat fraction for all 34 subjects was 0.7 ± 0.5% (range: 0.11–3%) assessed with MRS and 1.04 ± 0.4% (range: 0.32–2.44%) assessed with in- and out-of-phase MRI (P < 0.05). Scanning times were less than 15 sec for Dixon imaging, plus an additional minute for the acquisition used for calculation, and 15-20 min for MRS. The average postprocessing time for MRS was 3 min and 5 min for MRI including T2∗ measurement. We conclude that the dual echo method provides a rapid means to detect and quantifying myocardial fat content in vivo. Correction/adjustment for field inhomogeneity using three or more echoes seems crucial for the dual echo approach. PMID:20373390

  16. Neural activity in the hippocampus and perirhinal cortex during encoding is associated with the durability of episodic memory.

    PubMed

    Carr, Valerie A; Viskontas, Indre V; Engel, Stephen A; Knowlton, Barbara J

    2010-11-01

    Studies examining medial temporal lobe (MTL) involvement in memory formation typically assess memory performance after a single, short delay. Thus, the relationship between MTL encoding activity and memory durability over time remains poorly characterized. To explore this relationship, we scanned participants using high-resolution functional imaging of the MTL as they encoded object pairs; using the remember/know paradigm, we then assessed memory performance for studied items both 10 min and 1 week later. Encoding trials were classified as either subsequently recollected across both delays, transiently recollected (i.e., recollected at 10 min but not after 1 week), consistently familiar, or consistently forgotten. Activity in perirhinal cortex (PRC) and a hippocampal subfield comprising the dentate gyrus and CA fields 2 and 3 reflected successful encoding only when items were recollected consistently across both delays. Furthermore, in PRC, encoding activity for items that later were consistently recollected was significantly greater than that for transiently recollected and consistently familiar items. Parahippocampal cortex, in contrast, showed a subsequent memory effect during encoding of items that were recollected after 10 min, regardless of whether they also were recollected after 1 week. These data suggest that MTL subfields contribute uniquely to the formation of memories that endure over time, and highlight a role for PRC in supporting subsequent durable episodic recollection.

  17. Influence of Thermal Treatment Conditions on the Properties of Dental Silicate Cements.

    PubMed

    Voicu, Georgeta; Popa, Alexandru Mihai; Badanoiu, Alina Ioana; Iordache, Florin

    2016-02-18

    In this study the sol-gel process was used to synthesize a precursor mixture for the preparation of silicate cement, also called mineral trioxide aggregate (MTA) cement. This mixture was thermally treated under two different conditions (1400 °C/2 h and 1450 °C/3 h) followed by rapid cooling in air. The resulted material (clinker) was ground for one hour in a laboratory planetary mill (v = 150 rot/min), in order to obtain the MTA cements. The setting time and mechanical properties, in vitro induction of apatite formation by soaking in simulated body fluid (SBF) and cytocompatibility of the MTA cements were assessed in this study. The hardening processes, nature of the reaction products and the microstructural characteristics were also investigated. The anhydrous and hydrated cements were characterized by different techniques e.g., X-ray diffraction (XRD), scanning electron microscopy (SEM), infrared spectroscopy (FT-IR) and thermal analysis (DTA-DTG-TG). The setting time of the MTA cement obtained by thermal treatment at 1400 °C/2 h (MTA1) was 55 min and 15 min for the MTA cement obtained at 1450 °C/3 h (MTA2). The compressive strength values were 18.5 MPa (MTA1) and 22.9 MPa (MTA2). Both MTA cements showed good bioactivity (assessed by an in vitro test), good cytocompatibility and stimulatory effect on the proliferation of cells.

  18. Silicon drift detectors as a tool for time-resolved fluorescence XAFS on low-concentrated samples in catalysis.

    PubMed

    Kappen, Peter; Tröger, Larc; Materlik, Gerhard; Reckleben, Christian; Hansen, Karsten; Grunwaldt, Jan-Dierk; Clausen, Bjerne S

    2002-07-01

    A silicon drift detector (SDD) was used for ex situ and time-resolved in situ fluorescence X-ray absorption fine structure (XAFS) on low-concentrated catalyst samples. For a single-element and a seven-element SDD the energy resolution and the peak-to-background ratio were verified at high count rates, sufficient for fluorescence XAFS. An experimental set-up including the seven-element SDD without any cooling and an in situ cell with gas supply and on-line gas analysis was developed. With this set-up the reduction and oxidation of a zeolite supported catalyst containing 0.3 wt% platinum was followed by fluorescence near-edge scans with a time resolution of 10 min each. From ex situ experiments on low-concentrated platinum- and gold-based catalysts fluorescence XAFS scans could be obtained with sufficient statistical quality for a quantitative analysis. Structural information on the gold and platinum particles could be extracted by both the Fourier transforms and the near-edge region of the XAFS spectra. Moreover, it was found that with the seven-element SDD concentrations of the element of interest as low as 100 ppm can be examined by fluorescence XAFS.

  19. Effects of gradient encoding and number of signal averages on fractional anisotropy and fiber density index in vivo at 1.5 tesla.

    PubMed

    Widjaja, E; Mahmoodabadi, S Z; Rea, D; Moineddin, R; Vidarsson, L; Nilsson, D

    2009-01-01

    Tensor estimation can be improved by increasing the number of gradient directions (NGD) or increasing the number of signal averages (NSA), but at a cost of increased scan time. To evaluate the effects of NGD and NSA on fractional anisotropy (FA) and fiber density index (FDI) in vivo. Ten healthy adults were scanned on a 1.5T system using nine different diffusion tensor sequences. Combinations of 7 NGD, 15 NGD, and 25 NGD with 1 NSA, 2 NSA, and 3 NSA were used, with scan times varying from 2 to 18 min. Regions of interest (ROIs) were placed in the internal capsules, middle cerebellar peduncles, and splenium of the corpus callosum, and FA and FDI were calculated. Analysis of variance was used to assess whether there was a difference in FA and FDI of different combinations of NGD and NSA. There was no significant difference in FA of different combinations of NGD and NSA of the ROIs (P>0.005). There was a significant difference in FDI between 7 NGD/1 NSA and 25 NGD/3 NSA in all three ROIs (P<0.005). There were no significant differences in FDI between 15 NGD/3 NSA, 25 NGD/1 NSA, and 25 NGD/2 NSA and 25 NGD/3 NSA in all ROIs (P>0.005). We have not found any significant difference in FA with varying NGD and NSA in vivo in areas with relatively high anisotropy. However, lower NGD resulted in reduced FDI in vivo. With larger NGD, NSA has less influence on FDI. The optimal sequence among the nine sequences tested with the shortest scan time was 25 NGD/1 NSA.

  20. Safety of Landiolol Hydrochloride as a Premedication for Producing an Appropriate Heart Rate for Multidetector-Row Computed Tomography Coronary Angiography.

    PubMed

    Koyoshi, Rie; Shiga, Yuhei; Idemoto, Yoshiaki; Ueda, Yoko; Tashiro, Kohei; Kuwano, Takashi; Kitajima, Ken; Fujimi, Kanta; Kawamura, Akira; Ogawa, Masahiro; Miura, Shin-Ichiro

    2018-01-01

    We evaluated the safety of a bolus injection of landiolol hydrochloride, an ultrashort-acting β1-selective antagonist, as a premedication prior to multidetector-row computed tomography coronary angiography (CTA). The subjects consisted of 176 patients (M/F = 64:112, 67 ± 11 years) who had heart rate (HR) at rest ≥ 70 beats/min (bpm) and underwent CTA. Systolic/diastolic blood pressure (SBP/DBP) and HR were measured before and after the administration of landiolol. SBP/DBP and HR upon entry to the CT room were 136 ± 17/80 ± 11 mm Hg and 83 ± 10 bpm, respectively. HR was significantly reduced at the time of CTA scan (62 ± 7 bpm). Next, we divided the patients into three groups according to HR upon entry to the CT room: 70 - 79 bpm (n = 76), 80 - 89 bpm (n = 60) and ≥ 90 bpm (n = 40). HR at the time of CTA scan was significantly lower than that upon entry to the CT room in all three groups: 70 - 79 bpm (74 ± 3 bpm upon entry to the CT room to 61 ± 6 bpm at the time of CAT scan), 80 - 89 bpm (84 ± 3 to 63 ± 7 bpm) and ≥ 90 bpm (98 ± 6 to 65 ± 7 bpm). Although SBP/DBP was significantly decreased after the CTA scan (123 ± 18/72 ± 12 mm Hg), landiolol had no severe adverse events throughout CTA. In conclusion, a bolus injection of landiolol reduced HR by about 20 bpm without any severe adverse effects. Thus, a bolus injection of landiolol hydrochloride may be a suitable pretreatment for controlling HR in CTA.

  1. Evaluation of Two Commercial Systems for Automated Processing, Reading, and Interpretation of Lyme Borreliosis Western Blots▿

    PubMed Central

    Binnicker, M. J.; Jespersen, D. J.; Harring, J. A.; Rollins, L. O.; Bryant, S. C.; Beito, E. M.

    2008-01-01

    The diagnosis of Lyme borreliosis (LB) is commonly made by serologic testing with Western blot (WB) analysis serving as an important supplemental assay. Although specific, the interpretation of WBs for diagnosis of LB (i.e., Lyme WBs) is subjective, with considerable variability in results. In addition, the processing, reading, and interpretation of Lyme WBs are laborious and time-consuming procedures. With the need for rapid processing and more objective interpretation of Lyme WBs, we evaluated the performances of two automated interpretive systems, TrinBlot/BLOTrix (Trinity Biotech, Carlsbad, CA) and BeeBlot/ViraScan (Viramed Biotech AG, Munich, Germany), using 518 serum specimens submitted to our laboratory for Lyme WB analysis. The results of routine testing with visual interpretation were compared to those obtained by BLOTrix analysis of MarBlot immunoglobulin M (IgM) and IgG and by ViraScan analysis of ViraBlot and ViraStripe IgM and IgG assays. BLOTrix analysis demonstrated an agreement of 84.7% for IgM and 87.3% for IgG compared to visual reading and interpretation. ViraScan analysis of the ViraBlot assays demonstrated agreements of 85.7% for IgM and 94.2% for IgG, while ViraScan analysis of the ViraStripe IgM and IgG assays showed agreements of 87.1 and 93.1%, respectively. Testing by the automated systems yielded an average time savings of 64 min/run compared to processing, reading, and interpretation by our current procedure. Our findings demonstrated that automated processing and interpretive systems yield results comparable to those of visual interpretation, while reducing the subjectivity and time required for Lyme WB analysis. PMID:18463211

  2. Evaluation of two commercial systems for automated processing, reading, and interpretation of Lyme borreliosis Western blots.

    PubMed

    Binnicker, M J; Jespersen, D J; Harring, J A; Rollins, L O; Bryant, S C; Beito, E M

    2008-07-01

    The diagnosis of Lyme borreliosis (LB) is commonly made by serologic testing with Western blot (WB) analysis serving as an important supplemental assay. Although specific, the interpretation of WBs for diagnosis of LB (i.e., Lyme WBs) is subjective, with considerable variability in results. In addition, the processing, reading, and interpretation of Lyme WBs are laborious and time-consuming procedures. With the need for rapid processing and more objective interpretation of Lyme WBs, we evaluated the performances of two automated interpretive systems, TrinBlot/BLOTrix (Trinity Biotech, Carlsbad, CA) and BeeBlot/ViraScan (Viramed Biotech AG, Munich, Germany), using 518 serum specimens submitted to our laboratory for Lyme WB analysis. The results of routine testing with visual interpretation were compared to those obtained by BLOTrix analysis of MarBlot immunoglobulin M (IgM) and IgG and by ViraScan analysis of ViraBlot and ViraStripe IgM and IgG assays. BLOTrix analysis demonstrated an agreement of 84.7% for IgM and 87.3% for IgG compared to visual reading and interpretation. ViraScan analysis of the ViraBlot assays demonstrated agreements of 85.7% for IgM and 94.2% for IgG, while ViraScan analysis of the ViraStripe IgM and IgG assays showed agreements of 87.1 and 93.1%, respectively. Testing by the automated systems yielded an average time savings of 64 min/run compared to processing, reading, and interpretation by our current procedure. Our findings demonstrated that automated processing and interpretive systems yield results comparable to those of visual interpretation, while reducing the subjectivity and time required for Lyme WB analysis.

  3. Whole body sodium MRI at 3T using an asymmetric birdcage resonator and short echo time sequence: first images of a male volunteer

    NASA Astrophysics Data System (ADS)

    Wetterling, Friedrich; Corteville, Dominique M.; Kalayciyan, Raffi; Rennings, Andreas; Konstandin, Simon; Nagel, Armin M.; Stark, Helmut; Schad, Lothar R.

    2012-07-01

    Sodium magnetic resonance imaging (23Na MRI) is a non-invasive technique which allows spatial resolution of the tissue sodium concentration (TSC) in the human body. TSC measurements could potentially serve to monitor early treatment success of chemotherapy on patients who suffer from whole body metastases. Yet, the acquisition of whole body sodium (23Na) images has been hampered so far by the lack of large resonators and the extremely low signal-to-noise ratio (SNR) achieved with existing resonator systems. In this study, a 23Na resonator was constructed for whole body 23Na MRI at 3T comprising of a 16-leg, asymmetrical birdcage structure with 34 cm height, 47.5 cm width and 50 cm length. The resonator was driven in quadrature mode and could be used either as a transceiver resonator or, since active decoupling was included, as a transmit-only resonator in conjunction with a receive-only (RO) surface resonator. The relative B1-field profile was simulated and measured on phantoms, and 3D whole body 23Na MRI data of a healthy male volunteer were acquired in five segments with a nominal isotropic resolution of (6 × 6 × 6) mm3 and a 10 min acquisition time per scan. The measured SNR values in the 23Na-MR images varied from 9 ± 2 in calf muscle, 15 ± 2 in brain tissue, 23 ± 2 in the prostate and up to 42 ± 5 in the vertebral discs. Arms, legs, knees and hands could also be resolved with applied resonator and short time-to-echo (TE) (0.5 ms) radial sequence. Up to fivefold SNR improvement was achieved through combining the birdcage with local RO surface coil. In conclusion, 23Na MRI of the entire human body provides sub-cm spatial resolution, which allows resolution of all major human body parts with a scan time of less than 60 min.

  4. SU-G-IeP1-12: Size Selective Arterial Cerebral Blood Volume Mapping Using Multiple Inversion Time Arterial Spin Labeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jung, Y; Johnston, M; Whitlow, C

    Purpose: To demonstrate the feasibility of a novel method for size specific arterial cerebral blood volume (aCBV) mapping using pseudo-continuous arterial spin labeling (PCASL), with multiple TI. Methods: Multiple PCASL images were obtained from a subject with TI of [300, 400, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3500, 4000] ms. Each TI pair was averaged six times. Two scans were performed: one without a flow crusher gradient and the other with a crusher gradient (10cm/s in three directions) to remove signals from large arteries. Scan times were 5min. without a crusher gradient and 5.5 min withmore » a crusher gradient. Non-linear fitting algorithm finds the minimum mean squared solution of per-voxel based aCBV, cerebral blood flow, and arterial transit time, and fits the data into a hemodynamic model that represents superposition of blood volume and flow components within a single voxel. Results: aCBV maps with a crusher gradient represent signals from medium and small sized arteries, while those without a crusher gradient represent signals from all sized arteries, indicating that flow crusher gradients can be effectively employed to achieve size-specific aCBV mapping. Regardless of flow crusher, the CBF and ATT maps are very similar in appearance. Conclusion: Quantitative size selective blood volume mapping controlled by a flow crusher is feasible without additional information because the ASL quantification process doesn’t require an arterial input function measured from a large artery. The size specific blood volume mapping is not interfered by sSignals from large arteries do not interfere with size specific aCBV mapping in the applications of interest in for applications in which only medium or small arteries are of interest.« less

  5. Alignment of the lower extremity mechanical axis by computer-aided design and application in total knee arthroplasty.

    PubMed

    Zhang, Yuan Z; Lu, Sheng; Zhang, Hui Q; Jin, Zhong M; Zhao, Jian M; Huang, Jian; Zhang, Zhi F

    2016-10-01

    The success of total knee arthroplasty (TKA) depends on many factors. The position of a prosthesis is vitally important. The purpose of the present study was to evaluate the value of a computer-aided establishing lower extremity mechanical axis in TKA using digital technology. A total of 36 cases of patients with TKA were randomly divided into the computer-aided design of navigation template group (NT) and conventional intramedullary positioning group (CIP). Three-dimensional (3D) CT scanning images of the hip, knee, and ankle were obtained in NT group. X-ray images and CT scans were transferred into the 3D reconstruction software. A 3D bone model of the hip, knee, ankle, as well as the modified loading, was reconstructed and saved in a stereolithographic format. In the 3D reconstruction model, the mechanical axis of the lower limb was determined, and the navigational templates produced an accurate model using a rapid prototyping technique. The THA in CIP group was performed according to a routine operation. CT scans were performed postoperatively to evaluate the accuracy of the two TKA methods. The averaged operative time of the NT group procedures was [Formula: see text] min shorter than those of the conventional procedures ([Formula: see text]  min). The coronal femoral angle, coronal tibial angle, posterior tibial slope were [Formula: see text], [Formula: see text], [Formula: see text] in NT group and [Formula: see text], [Formula: see text], [Formula: see text] in CIP group, respectively. Statistically significant group differences were found. The navigation template produced through mechanical axis of lower extremity may provide a relative accurate and simple method for TKA.

  6. Cerebral metabolic rate of oxygen (CMRO2 ) mapping with hyperventilation challenge using quantitative susceptibility mapping (QSM).

    PubMed

    Zhang, Jingwei; Zhou, Dong; Nguyen, Thanh D; Spincemaille, Pascal; Gupta, Ajay; Wang, Yi

    2017-05-01

    Our objective was to demonstrate the feasibility of using hyperventilation as an efficient vasoconstrictive challenge and prior knowledge as denoising constraints for cerebral metabolic rate of oxygen (CMRO 2 ) mapping based upon quantitative susceptibility mapping (QSM). Three-dimensional (3D) multi-echo gradient echo and arterial spin labeling imaging were performed to calculate QSM and perfusion maps before and after a hyperventilation challenge in 11 healthy subjects. For comparison, this was repeated using a caffeine challenge. Whole-brain CMRO 2 and oxygen extraction fraction (OEF) maps were computed using constrained optimization. Hyperventilation scans were repeated to measure reproducibility. Regional agreement of CMRO 2 and OEF maps was analyzed within the cortical gray matter (CGM) using t-test and Bland-Altman plots. Hyperventilation challenge eliminates the 30-min waiting time needed for caffeine to exert its vasoconstrictive effects. Mean CMRO 2 (in µmol/100g/min) obtained in CGM using the caffeine and repeated hyperventilation scans were 149 ± 16, 153 ± 19, and 150 ± 20, respectively. This corresponded to an OEF of 33.6 ± 3.4%, 32.3 ± 3.2%, and 34.1 ± 3.8% at baseline state and 39.8 ± 4.8%, 43.6 ± 6.2%, and 42.8 ± 6.8% at challenged state, respectively. Hyperventilation scans produced a good agreement of CMRO 2 and OEF values. Hyperventilation is a feasible, reproducible, and efficient vasoconstrictive challenge for QSM-based quantitative CMRO 2 mapping. Magn Reson Med 77:1762-1773, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  7. Laparoscopic trans-mesocolic pyeloplasty in children: initial experience from a center in India.

    PubMed

    Khan, Muneer; Ahangar, Shahnawaz; Nazir, Syed Sajjad; Qadri, Syed Javid Farooq; Salroo, Nazir Ahmad

    2011-07-01

    The aim of the present study is to report our experience with laparoscopic pyeloplasty via trans-mesocolic approach in children with left pelvi-ureteric junction (PUJ) obstruction. Between May 2007 and May 2008, 12 children aged between five and 16 years, with documented PUJ obstruction on the left side, underwent laparoscopic pyeloplasty via trans-mesocolic approach. The outcome was assessed by post-operative isotope renal scan. The mean age of the study patients was eight years, ranging between five and 16 years. There were five males and seven females in the study. All children underwent Anderson Hynes Pyeloplasty by a single surgeon. All cases were stented with a JJ stent for a period of six weeks post-operatively. The procedures were completed successfully in all patients without need for conversion to open pyeloplasty in any patient. The mean operative time was 95 min, with a range of 80-140 min. The average blood loss was 57 mL. The mean hospital stay was 3.5 days with a range of 2.5 to six days. All children returned back to school within nine days following surgery. The mean follow-up period was 12 months (range, nine to 14 months). Eleven of the patients were completely asymptomatic, while one reported mild flank pain. All children underwent renal scans and renal ultrasound three months after stent removal. Ten had improved function on the scan while in one patient, the function remained the same and, in another, it showed obstructed response to diuretic, although the symptoms had improved. In all the cases, renal ultrasound showed a decrease in the severity of hydronephrosis by at least one degree. These results confirm that laparoscopic pyeloplasty by trans-mesocolic approach in children for left-sided PUJ obstruction is safe and feasible.

  8. A comparative study of conventionally sintered and microwave sintered nickel zinc ferrite

    NASA Astrophysics Data System (ADS)

    Rani, Rekha; Juneja, J. K.; Raina, K. K.; Kotnala, R. K.; Prakash, Chandra

    2014-04-01

    For the present work, nickel zinc ferrite having compositional formula Ni0.8Zn0.2Fe2O4 was synthesized by conventional solid state method and sintered in conventional and microwave furnaces. Pellets were sintered with very short soaking time of 10 min at 1150 °C in microwave furnace whereas 4 hrs of soaking time was selected for conventional sintering at 1200 °C. Phase formation was confirmed by X-ray diffraction analysis technique. Scanning electron micrographs were taken for microstructural study. Dielectric properties were studied as a function of temperature. To study magnetic behavior, M-H hysteresis loops were recorded for both samples. It is observed that microwave sintered sample could obtain comparable properties to the conventionally sintered one in lesser soaking time at lower sintering temperature.

  9. Search for solar neutrons using NM-64 equipment

    NASA Technical Reports Server (NTRS)

    Martinic, N. J.; Reguerin, A.; Palenque, E.; Taquichiri, M. A.; Wada, M.; Inoue, A.; Takahashi, K.

    1985-01-01

    Two years (1980 to 1982) neutron monitor data from the Chacaltaya (geographic coordinates: N16.32 deg W68. 15 deg; cutoff rigidity: 13.1 GV; altitude: 5,300 m a.s.l.) station has been scanned; the sampling time of the 12NM-64 neutron monitor is 5 min. The nucleonic component increases have been correlated with 66 hard X-, gamma rays satellite data from solar origin, as reported by several groups. Typical neutron monitor time profiles of the events are presented. Chree-analysis was performed discriminating the events according to its solar coordinates. Ground data from solar limb locii are more enhanced at the time of the onset than other geometrically visible flares. Chree histograms of neutron monitor output profiles are also presented from geometrically invisible events from the Chacaltaya station.

  10. Concrete thawing studied by single-point ramped imaging.

    PubMed

    Prado, P J; Balcom, B J; Beyea, S D; Armstrong, R L; Bremner, T W

    1997-12-01

    A series of two-dimensional images of proton distribution in a hardened concrete sample has been obtained during the thawing process (from -50 degrees C up to 11 degrees C). The SPRITE sequence is optimal for this study given the characteristic short relaxation times of water in this porous media (T2* < 200 micros and T1 < 3.6 ms). The relaxation parameters of the sample were determined in order to optimize the time efficiency of the sequence, permitting a 4-scan 64 x 64 acquisition in under 3 min. The image acquisition is fast on the time scale of the temperature evolution of the specimen. The frozen water distribution is quantified through a position based study of the image contrast. A multiple point acquisition method is presented and the signal sensitivity improvement is discussed.

  11. Hierarchical pictorial structures for simultaneously localizing multiple organs in volumetric pre-scan CT

    NASA Astrophysics Data System (ADS)

    Montillo, Albert; Song, Qi; Das, Bipul; Yin, Zhye

    2015-03-01

    Parsing volumetric computed tomography (CT) into 10 or more salient organs simultaneously is a challenging task with many applications such as personalized scan planning and dose reporting. In the clinic, pre-scan data can come in the form of very low dose volumes acquired just prior to the primary scan or from an existing primary scan. To localize organs in such diverse data, we propose a new learning based framework that we call hierarchical pictorial structures (HPS) which builds multiple levels of models in a tree-like hierarchy that mirrors the natural decomposition of human anatomy from gross structures to finer structures. Each node of our hierarchical model learns (1) the local appearance and shape of structures, and (2) a generative global model that learns probabilistic, structural arrangement. Our main contribution is twofold. First we embed the pictorial structures approach in a hierarchical framework which reduces test time image interpretation and allows for the incorporation of additional geometric constraints that robustly guide model fitting in the presence of noise. Second we guide our HPS framework with the probabilistic cost maps extracted using random decision forests using volumetric 3D HOG features which makes our model fast to train and fast to apply to novel test data and posses a high degree of invariance to shape distortion and imaging artifacts. All steps require approximate 3 mins to compute and all organs are located with suitably high accuracy for our clinical applications such as personalized scan planning for radiation dose reduction. We assess our method using a database of volumetric CT scans from 81 subjects with widely varying age and pathology and with simulated ultra-low dose cadaver pre-scan data.

  12. Electrochemical properties of monolithic nickel sulfide electrodes for use in sodium batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Go, Dae-Yeon; Park, Jinsoo, E-mail: jsp@ikw.ac.kr; Noh, Pan-Jin

    2014-10-15

    Highlights: • We succeeded in preparing monolithic Ni{sub 3}S{sub 2} integrated electrode through the sulfuration. • The sulfuration is a facile and useful method to synthesize metal sulfides with nanostructure. • As-prepared monolithic Ni{sub 3}S{sub 2} electrodes showed very stable and cycle performance over charge/discharge cycling. - Abstract: Monolithic nickel sulfide electrodes were prepared using a facile synthesis method, sulfuration and annealing. As-prepared Ni{sub 3}S{sub 2} electrodes were characterized by X-ray diffractometry and field emission scanning electron microscopy. Thermal stability was determined by thermal gravimetric analysis and differential scanning calorimetry. Electrochemical properties were measured by galvanostatic charge and discharge cyclingmore » for Na-ion batteries. Three kinds of Ni{sub 3}S{sub 2} electrodes were prepared by varying the sulfuration time (5, 15 and 25 min). The electrochemical results indicated that the capacities increased with an increase in sulfuration time and the cycle performance was stable as a result of monolithic integration of nanostructured Ni{sub 3}S{sub 2} on Ni plates, leading to low interfacial resistance.« less

  13. Evaluation of a single-scan protocol for radiochromic film dosimetry.

    PubMed

    Shimohigashi, Yoshinobu; Araki, Fujio; Maruyama, Masato; Nakaguchi, Yuji; Kuwahara, Satoshi; Nagasue, Nozomu; Kai, Yudai

    2015-03-08

    The purpose of this study was to evaluate a single-scan protocol using Gafchromic EBT3 film (EBT3) by comparing it with the commonly used 24-hr measurement protocol for radiochromic film dosimetry. Radiochromic film is generally scanned 24 hr after film exposure (24-hr protocol). The single-scan protocol enables measurement results within a short time using only the verification film, one calibration film, and unirradiated film. The single-scan protocol was scanned 30 min after film irradiation. The EBT3 calibration curves were obtained with the multichannel film dosimetry method. The dose verifications for each protocol were performed with the step pattern, pyramid pattern, and clinical treatment plans for intensity-modulated radiation therapy (IMRT). The absolute dose distributions for each protocol were compared with those calculated by the treatment planning system (TPS) using gamma evaluation at 3% and 3 mm. The dose distribution for the single-scan protocol was within 2% of the 24-hr protocol dose distribution. For the step pattern, the absolute dose discrepancies between the TPS for the single-scan and 24-hr protocols were 2.0 ± 1.8 cGy and 1.4 ± 1.2 cGy at the dose plateau, respectively. The pass rates were 96.0% for the single-scan protocol and 95.9% for the 24-hr protocol. Similarly, the dose discrepancies for the pyramid pattern were 3.6 ± 3.5cGy and 2.9 ± 3.3 cGy, respectively, while the pass rates for the pyramid pattern were 95.3% and 96.4%, respectively. The average pass rates for the four IMRT plans were 96.7% ± 1.8% for the single-scan protocol and 97.3% ± 1.4% for the 24-hr protocol. Thus, the single-scan protocol measurement is useful for dose verification of IMRT, based on its accuracy and efficiency.

  14. Evaluation of a single‐scan protocol for radiochromic film dosimetry

    PubMed Central

    Araki, Fujio; Maruyama, Masato; Nakaguchi, Yuji; Kuwahara, Satoshi; Nagasue, Nozomu; Kai, Yudai

    2015-01-01

    The purpose of this study was to evaluate a single‐scan protocol using Gafchromic EBT3 film (EBT3) by comparing it with the commonly used 24‐hr measurement protocol for radiochromic film dosimetry. Radiochromic film is generally scanned 24 hr after film exposure (24‐hr protocol). The single‐scan protocol enables measurement results within a short time using only the verification film, one calibration film, and unirradiated film. The single‐scan protocol was scanned 30 min after film irradiation. The EBT3 calibration curves were obtained with the multichannel film dosimetry method. The dose verifications for each protocol were performed with the step pattern, pyramid pattern, and clinical treatment plans for intensity‐modulated radiation therapy (IMRT). The absolute dose distributions for each protocol were compared with those calculated by the treatment planning system (TPS) using gamma evaluation at 3% and 3 mm. The dose distribution for the single‐scan protocol was within 2% of the 24‐hr protocol dose distribution. For the step pattern, the absolute dose discrepancies between the TPS for the single‐scan and 24‐hr protocols were 2.0±1.8 cGy and 1.4±1.2 cGy at the dose plateau, respectively. The pass rates were 96.0% for the single‐scan protocol and 95.9% for the 24‐hr protocol. Similarly, the dose discrepancies for the pyramid pattern were 3.6±3.5 cGy and 2.9±3.3 cGy, respectively, while the pass rates for the pyramid pattern were 95.3% and 96.4%, respectively. The average pass rates for the four IMRT plans were 96.7%±1.8% for the single‐scan protocol and 97.3%±1.4% for the 24‐hr protocol. Thus, the single‐scan protocol measurement is useful for dose verification of IMRT, based on its accuracy and efficiency. PACS number: 87.55.Qr PMID:26103194

  15. The brain's silent messenger: using selective attention to decode human thought for brain-based communication.

    PubMed

    Naci, Lorina; Cusack, Rhodri; Jia, Vivian Z; Owen, Adrian M

    2013-05-29

    The interpretation of human thought from brain activity, without recourse to speech or action, is one of the most provoking and challenging frontiers of modern neuroscience. In particular, patients who are fully conscious and awake, yet, due to brain damage, are unable to show any behavioral responsivity, expose the limits of the neuromuscular system and the necessity for alternate forms of communication. Although it is well established that selective attention can significantly enhance the neural representation of attended sounds, it remains, thus far, untested as a response modality for brain-based communication. We asked whether its effect could be reliably used to decode answers to binary (yes/no) questions. Fifteen healthy volunteers answered questions (e.g., "Do you have brothers or sisters?") in the fMRI scanner, by selectively attending to the appropriate word ("yes" or "no"). Ninety percent of the answers were decoded correctly based on activity changes within the attention network. The majority of volunteers conveyed their answers with less than 3 min of scanning, suggesting that this technique is suited for communication in a reasonable amount of time. Formal comparison with the current best-established fMRI technique for binary communication revealed improved individual success rates and scanning times required to detect responses. This novel fMRI technique is intuitive, easy to use in untrained participants, and reliably robust within brief scanning times. Possible applications include communication with behaviorally nonresponsive patients.

  16. Cross-sectional structural parameters from densitometry

    NASA Technical Reports Server (NTRS)

    Cleek, Tammy M.; Whalen, Robert T.

    2002-01-01

    Bone densitometry has previously been used to obtain cross-sectional properties of bone from a single X-ray projection across the bone width. Using three unique projections, we have extended the method to obtain the principal area moments of inertia and orientations of the principal axes at each scan cross-section along the length of the scan. Various aluminum phantoms were used to examine scanner characteristics to develop the highest accuracy possible for in vitro non-invasive analysis of cross-sectional properties. Factors considered included X-ray photon energy, initial scan orientation, the angle spanned by the three scans (included angle), and I(min)/I(max) ratios. Principal moments of inertia were accurate to within +/-3.1% and principal angles were within +/-1 degrees of the expected value for phantoms scanned with included angles of 60 degrees and 90 degrees at the higher X-ray photon energy (140 kVp). Low standard deviations in the error (0.68-1.84%) also indicate high precision of calculated measurements with these included angles. Accuracy and precision decreased slightly when the included angle was reduced to 30 degrees. The method was then successfully applied to a pair of excised cadaveric tibiae. The accuracy and insensitivity of the algorithms to cross-sectional shape and changing isotropy (I(min)/I(max)) values when various included angles are used make this technique viable for future in vivo studies.

  17. The first clinical application of planning software for laparoscopic microwave thermosphere ablation of malignant liver tumours.

    PubMed

    Berber, Eren

    2015-07-01

    Liver tumour ablation is an operator-dependent procedure. The determination of the optimum needle trajectory and correct ablation parameters could be challenging. The aim of this study was to report the utility of a new, procedure planning software for microwave ablation (MWA) of liver tumours. This was a feasibility study in a pilot group of five patients with nine metastatic liver tumours who underwent laparoscopic MWA. Pre-operatively, parameters predicting the desired ablation zones were calculated for each tumour. Intra-operatively, this planning strategy was followed for both antenna placement and energy application. Post-operative 2-week computed tomography (CT) scans were performed to evaluate complete tumour destruction. The patients had an average of two tumours (range 1-4), measuring 1.9 ± 0.4 cm (range 0.9-4.4 cm). The ablation time was 7.1 ± 1.3 min (range 2.5-10 min) at 100W. There were no complications or mortality. The patients were discharged home on post-operative day (POD) 1. At 2-week CT scans, there were no residual tumours, with a complete ablation demonstrated in all lesions. This study describes and validates pre-treatment planning software for MWA of liver tumours. This software was found useful to determine precisely the ablation parameters and needle placement to create a predicted zone of ablation. © 2015 International Hepato-Pancreato-Biliary Association.

  18. Head motion evaluation and correction for PET scans with 18F-FDG in the Japanese Alzheimer's disease neuroimaging initiative (J-ADNI) multi-center study.

    PubMed

    Ikari, Yasuhiko; Nishio, Tomoyuki; Makishi, Yoko; Miya, Yukari; Ito, Kengo; Koeppe, Robert A; Senda, Michio

    2012-08-01

    Head motion during 30-min (six 5-min frames) brain PET scans starting 30 min post-injection of FDG was evaluated together with the effect of post hoc motion correction between frames in J-ADNI multicenter study carried out in 24 PET centers on a total of 172 subjects consisting of 81 normal subjects, 55 mild cognitive impairment (MCI) and 36 mild Alzheimer's disease (AD) patients. Based on the magnitude of the between-frame co-registration parameters, the scans were classified into six levels (A-F) of motion degree. The effect of motion and its correction was evaluated using between-frame variation of the regional FDG uptake values on ROIs placed over cerebral cortical areas. Although AD patients tended to present larger motion (motion level E or F in 22 % of the subjects) than MCI (3 %) and normal (4 %) subjects, unignorable motion was observed in a small number of subjects in the latter groups as well. The between-frame coefficient of variation (SD/mean) was 0.5 % in the frontal, 0.6 % in the parietal and 1.8 % in the posterior cingulate ROI for the scans of motion level 1. The respective values were 1.5, 1.4, and 3.6 % for the scans of motion level F, but reduced by the motion correction to 0.5, 0.4 and 0.8 %, respectively. The motion correction changed the ROI value for the posterior cingulate cortex by 11.6 % in the case of severest motion. Substantial head motion occurs in a fraction of subjects in a multicenter setup which includes PET centers lacking sufficient experience in imaging demented patients. A simple frame-by-frame co-registration technique that can be applied to any PET camera model is effective in correcting for motion and improving quantitative capability.

  19. Performance of e-ASPECTS software in comparison to that of stroke physicians on assessing CT scans of acute ischemic stroke patients.

    PubMed

    Herweh, Christian; Ringleb, Peter A; Rauch, Geraldine; Gerry, Steven; Behrens, Lars; Möhlenbruch, Markus; Gottorf, Rebecca; Richter, Daniel; Schieber, Simon; Nagel, Simon

    2016-06-01

    The Alberta Stroke Program Early CT score (ASPECTS) is an established 10-point quantitative topographic computed tomography scan score to assess early ischemic changes. We compared the performance of the e-ASPECTS software with those of stroke physicians at different professional levels. The baseline computed tomography scans of acute stroke patients, in whom computed tomography and diffusion-weighted imaging scans were obtained less than two hours apart, were retrospectively scored by e-ASPECTS as well as by three stroke experts and three neurology trainees blinded to any clinical information. The ground truth was defined as the ASPECTS on diffusion-weighted imaging scored by another two non-blinded independent experts on consensus basis. Sensitivity and specificity in an ASPECTS region-based and an ASPECTS score-based analysis as well as receiver-operating characteristic curves, Bland-Altman plots with mean score error, and Matthews correlation coefficients were calculated. Comparisons were made between the human scorers and e-ASPECTS with diffusion-weighted imaging being the ground truth. Two methods for clustered data were used to estimate sensitivity and specificity in the region-based analysis. In total, 34 patients were included and 680 (34 × 20) ASPECTS regions were scored. Mean time from onset to computed tomography was 172 ± 135 min and mean time difference between computed tomographyand magnetic resonance imaging was 41 ± 31 min. The region-based sensitivity (46.46% [CI: 30.8;62.1]) of e-ASPECTS was better than three trainees and one expert (p ≤ 0.01) and not statistically different from another two experts. Specificity (94.15% [CI: 91.7;96.6]) was lower than one expert and one trainee (p < 0.01) and not statistically different to the other four physicians. e-ASPECTS had the best Matthews correlation coefficient of 0.44 (experts: 0.38 ± 0.08 and trainees: 0.19 ± 0.05) and the lowest mean score error of 0.56 (experts: 1.44 ± 1.79 and trainees: 1.97 ± 2.12). e-ASPECTS showed a similar performance to that of stroke experts in the assessment of brain computed tomographys of acute ischemic stroke patients with the Alberta Stroke Program Early CT score method. © 2016 World Stroke Organization.

  20. Quantification of myocardial perfusion based on signal intensity of flow sensitized MRI

    NASA Astrophysics Data System (ADS)

    Abeykoon, Sumeda B.

    The quantitative assessment of perfusion is important for early recognition of a variety of heart diseases, determination of disease severity and their cure. In conventional approach of measuring cardiac perfusion by arterial spin labeling, the relative difference in the apparent T1 relaxation times in response to selective and non-selective inversion of blood entering the region of interest is related to perfusion via a two-compartment tissue model. But accurate determination of T1 in small animal hearts is difficult and prone to errors due to long scan times. The purpose of this study is to develop a fast, robust and simple method to quantitatively assess myocardial perfusion using arterial spin labeling. The proposed method is based on signal intensities (SI) of inversion recovery slice-select, non-select and steady-state images. Especially in this method data are acquired at a single inversion time and at short repetition times. This study began by investigating the accuracy of assessment of perfusion using a two compartment system. First, determination of perfusion by T1 and SI were implemented to a simple, two-compartment phantom model. Mathematical model developed for full spin exchange models (in-vivo experiments) by solving a modified Bloch equation was modified to develop mathematical models (T1 and SI) for a phantom (zero spin exchange). The phantom result at different flow rates shows remarkable evidence of accuracy of the two-compartment model and SI, T1 methods: the SI method has less propagation error and less scan time. Next, twelve healthy C57BL/6 mice were scanned for quantitative perfusion assessment and three of them were repeatedly scanned at three different time points for a reproducibility test. The myocardial perfusion of healthy mice obtained by the SI-method, 5.7+/-1.6 ml/g/min, was similar (p=0.38) to that obtained by the conventional T1 method, 5.6+/- 2.3 ml/g/min. The reproducibility of the SI method shows acceptable results: the maximum percentage deviation is about 5%. Then the SI-method was used in comparison to a delayed enhanced method to qualitatively and quantitatively assess perfusion deficits in an ischemia-reperfusion (IR) mouse model. The infarcted region of the perfusion map is comparable to the hyper intense region of the delayed enhanced image of the IR mouse. The SI method also used to record a chronological comparison of perfusion on delta sarcoglycan null (DSG) mice. Perfusion of DSG and wild-type (WT) mice at ages of 12 weeks and 32 weeks were compared and percentage change of perfusion was estimated. The result shows that in DSG mice perfusion changes considerably. Finally, the SI method was implemented on a 3 Tesla Philip scanner by modifying to data acquisition method. The perfusion obtained in this is consistent with literature values but further adjustment of pulse sequence and modification of numerical solution is needed. The most important benefit of the SI method is that it reduces scan time 30%--40% and lessens motion artifacts of images compared to the T1 method. This study demonstrates that the signal intensity-based ASL method is a robust alternative to the conventional T1-method.

  1. Efficient use of retention time for the analysis of 302 drugs in equine plasma by liquid chromatography-MS/MS with scheduled multiple reaction monitoring and instant library searching for doping control.

    PubMed

    Liu, Ying; Uboh, Cornelius E; Soma, Lawrence R; Li, Xiaoqing; Guan, Fuyu; You, Youwen; Chen, Jin-Wen

    2011-09-01

    Multiple drug target analysis (MDTA) used in doping control is more efficient than single drug target analysis (SDTA). The number of drugs with the potential for abuse is so extensive that full coverage is not possible with SDTA. To address this problem, a liquid chromatography tandem mass spectrometric method was developed for simultaneous analysis of 302 drugs using a scheduled multiple reaction monitoring (s-MRM) algorithm. With a known retention time of an analyte, the s-MRM algorithm monitors each MRM transition only around its expected retention time. Analytes were recovered from plasma by liquid-liquid extraction. Information-dependent acquisition (IDA) functionality was used to combine s-MRM with enhanced product ion (EPI) scans within the same chromatographic analysis. An EPI spectrum library was also generated for rapid identification of analytes. Analysis time for the 302 drugs was 7 min. Scheduled MRM improved the quality of the chromatograms, signal response, reproducibility, and enhanced signal-to-noise ratio (S/N), resulting in more data points. Reduction in total cycle time from 2.4 s in conventional MRM (c-MRM) to 1 s in s-MRM allowed completion of the EPI scan at the same time. The speed for screening and identification of multiple drugs in equine plasma for doping control analysis was greatly improved by this method.

  2. High-throughput machining using high average power ultrashort pulse lasers and ultrafast polygon scanner

    NASA Astrophysics Data System (ADS)

    Schille, Joerg; Schneider, Lutz; Streek, André; Kloetzer, Sascha; Loeschner, Udo

    2016-03-01

    In this paper, high-throughput ultrashort pulse laser machining is investigated on various industrial grade metals (Aluminium, Copper, Stainless steel) and Al2O3 ceramic at unprecedented processing speeds. This is achieved by using a high pulse repetition frequency picosecond laser with maximum average output power of 270 W in conjunction with a unique, in-house developed two-axis polygon scanner. Initially, different concepts of polygon scanners are engineered and tested to find out the optimal architecture for ultrafast and precision laser beam scanning. Remarkable 1,000 m/s scan speed is achieved on the substrate, and thanks to the resulting low pulse overlap, thermal accumulation and plasma absorption effects are avoided at up to 20 MHz pulse repetition frequencies. In order to identify optimum processing conditions for efficient high-average power laser machining, the depths of cavities produced under varied parameter settings are analyzed and, from the results obtained, the characteristic removal values are specified. The maximum removal rate is achieved as high as 27.8 mm3/min for Aluminium, 21.4 mm3/min for Copper, 15.3 mm3/min for Stainless steel and 129.1 mm3/min for Al2O3 when full available laser power is irradiated at optimum pulse repetition frequency.

  3. [Retrospective computation of the ISS in multiple trauma patients: Potential pitfalls and limitations of findings in full body CT scans].

    PubMed

    Bogner, V; Brumann, M; Kusmenkov, T; Kanz, K G; Wierer, M; Berger, F; Mutschler, W

    2016-03-01

    The Injury Severity Score (ISS) is a well-established anatomical scoring system for polytraumatized patients. However, any inaccuracy in the Abbreviated Injury Score (AIS) directly increases the ISS impreciseness. Using the full body computed tomography (CT) scan report, ISS computation can be associated with certain pitfalls. This study evaluates interpretation variations depending on radiological reports and indicates requirements to reliably determine the ISS. The ISS of 81 polytraumatized patients was calculated based on the full body CT scan report. If an injury could not be attributed to a precise AIS cipher, the minimal and maximal ISS was computed. Real ISS included all conducted investigations, intraoperative findings, and final medical reports. The differences in ISS min, ISS max, and ISS real were evaluated using the Kruskal-Wallis test (p<0.05) and plotted in a linear regression analysis. Mean ISS min was 24.0 (± 0.7 SEM) points, mean ISS real 38.6 (±1.3 SEM) and mean ISS max was 48.3 (±1.4 SEM) points. All means were significantly different compared to one another (p<0.001). The difference between possible and real ISS showed a distinctive variation. Mean deviation was 9.7 (±0.9 SEM) points downward and 14.5 (±1.1 SEM) points upward. The difference between deviation to ISS min and ISS max was highly significant (p<0.001). Objectification of injury severity in polytraumatized patients using the ISS is an internationally well-established method in clinical and scientific settings. The full body CT scan report must meet distinct criteria and has to be written in acquaintance to the AIS scale if intended to be used for correct ISS computation.

  4. Safety, Biodistribution, and Radiation Dosimetry of 68Ga-OPS202 in Patients with Gastroenteropancreatic Neuroendocrine Tumors: A Prospective Phase I Imaging Study.

    PubMed

    Nicolas, Guillaume P; Beykan, Seval; Bouterfa, Hakim; Kaufmann, Jens; Bauman, Andreas; Lassmann, Michael; Reubi, Jean Claude; Rivier, Jean E F; Maecke, Helmut R; Fani, Melpomeni; Wild, Damian

    2018-06-01

    Preclinical and preliminary clinical evidence indicates that radiolabeled somatostatin (sst) receptor antagonists perform better than agonists in detecting neuroendocrine tumors (NETs). We performed a prospective phase I/II study to evaluate the sst receptor antagonist 68 Ga-OPS202 ( 68 Ga-NODAGA-JR11; NODAGA = 1,4,7-triazacyclononane,1-glutaric acid-4,7-acetic acid and JR11 = Cpa-c(dCys-Aph(Hor)-dAph(Cbm)-Lys-Thr-Cys)-dTyr-NH 2 )) for PET imaging. Here, we report the results of phase I of the study. Methods: Patients received 2 single 150-MBq intravenous injections of 68 Ga-OPS202 3-4 wk apart (15 μg of peptide at visit 1 and 50 μg at visit 2). At visit 1, a dynamic PET/CT scan over the kidney was obtained during the first 30 min after injection, and static whole-body scans were obtained at 0.5, 1, 2, and 4 h after injection; at visit 2, a static whole-body scan was obtained at 1 h. Blood samples and urine were collected at regular intervals to determine 68 Ga-OPS202 pharmacokinetics. Safety, biodistribution, radiation dosimetry, and the most appropriate imaging time point for 68 Ga-OPS202 were assessed. Results: Twelve patients with well-differentiated gastroenteropancreatic (GEP) NETs took part in the study. 68 Ga-OPS202 cleared rapidly from the blood, with a mean residence time of 2.4 ± 1.1 min/L. The organs with the highest mean dose coefficients were the urinary bladder wall, kidneys, and spleen. The calculated effective dose was 2.4E-02 ± 0.2E-02 mSv/MBq, corresponding to 3.6 mSv, for a reference activity of 150 MBq. Based on total numbers of detected malignant lesions, the optimal time window for the scan was between 1 and 2 h. For malignant liver lesions, the time point at which most patients had the highest mean tumor contrast was 1 h. 68 Ga-OPS202 was well tolerated; adverse events were grade 1 or 2, and there were no signals of concern from laboratory blood or urinalysis tests. Conclusion: 68 Ga-OPS202 showed favorable biodistribution and imaging properties, with optimal tumor contrast between 1 and 2 h after injection. Dosimetry analysis revealed that the dose delivered by 68 Ga-OPS202 to organs is similar to that delivered by other 68 Ga-labeled sst analogs. Further evaluation of 68 Ga-OPS202 for PET/CT imaging of NETs is therefore warranted. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  5. Quantification of both the area-at-risk and acute myocardial infarct size in ST-segment elevation myocardial infarction using T1-mapping.

    PubMed

    Bulluck, Heerajnarain; Hammond-Haley, Matthew; Fontana, Marianna; Knight, Daniel S; Sirker, Alex; Herrey, Anna S; Manisty, Charlotte; Kellman, Peter; Moon, James C; Hausenloy, Derek J

    2017-08-01

    A comprehensive cardiovascular magnetic resonance (CMR) in reperfused ST-segment myocardial infarction (STEMI) patients can be challenging to perform and can be time-consuming. We aimed to investigate whether native T1-mapping can accurately delineate the edema-based area-at-risk (AAR) and post-contrast T1-mapping and synthetic late gadolinium (LGE) images can quantify MI size at 1.5 T. Conventional LGE imaging and T2-mapping could then be omitted, thereby shortening the scan duration. Twenty-eight STEMI patients underwent a CMR scan at 1.5 T, 3 ± 1 days following primary percutaneous coronary intervention. The AAR was quantified using both native T1 and T2-mapping. MI size was quantified using conventional LGE, post-contrast T1-mapping and synthetic magnitude-reconstructed inversion recovery (MagIR) LGE and synthetic phase-sensitive inversion recovery (PSIR) LGE, derived from the post-contrast T1 maps. Native T1-mapping performed as well as T2-mapping in delineating the AAR (41.6 ± 11.9% of the left ventricle [% LV] versus 41.7 ± 12.2% LV, P = 0.72; R 2 0.97; ICC 0.986 (0.969-0.993); bias -0.1 ± 4.2% LV). There were excellent correlation and inter-method agreement with no bias, between MI size by conventional LGE, synthetic MagIR LGE (bias 0.2 ± 2.2%LV, P = 0.35), synthetic PSIR LGE (bias 0.4 ± 2.2% LV, P = 0.060) and post-contrast T1-mapping (bias 0.3 ± 1.8% LV, P = 0.10). The mean scan duration was 58 ± 4 min. Not performing T2 mapping (6 ± 1 min) and conventional LGE (10 ± 1 min) would shorten the CMR study by 15-20 min. T1-mapping can accurately quantify both the edema-based AAR (using native T1 maps) and acute MI size (using post-contrast T1 maps) in STEMI patients without major cardiovascular risk factors. This approach would shorten the duration of a comprehensive CMR study without significantly compromising on data acquisition and would obviate the need to perform T2 maps and LGE imaging.

  6. High-throughput machining using a high-average power ultrashort pulse laser and high-speed polygon scanner

    NASA Astrophysics Data System (ADS)

    Schille, Joerg; Schneider, Lutz; Streek, André; Kloetzer, Sascha; Loeschner, Udo

    2016-09-01

    High-throughput ultrashort pulse laser machining is investigated on various industrial grade metals (aluminum, copper, and stainless steel) and Al2O3 ceramic at unprecedented processing speeds. This is achieved by using a high-average power picosecond laser in conjunction with a unique, in-house developed polygon mirror-based biaxial scanning system. Therefore, different concepts of polygon scanners are engineered and tested to find the best architecture for high-speed and precision laser beam scanning. In order to identify the optimum conditions for efficient processing when using high-average laser powers, the depths of cavities made in the samples by varying the processing parameter settings are analyzed and, from the results obtained, the characteristic removal values are specified. For overlapping pulses of optimum fluence, the removal rate is as high as 27.8 mm3/min for aluminum, 21.4 mm3/min for copper, 15.3 mm3/min for stainless steel, and 129.1 mm3/min for Al2O3, when a laser beam of 187 W average laser powers irradiates. On stainless steel, it is demonstrated that the removal rate increases to 23.3 mm3/min when the laser beam is very fast moving. This is thanks to the low pulse overlap as achieved with 800 m/s beam deflection speed; thus, laser beam shielding can be avoided even when irradiating high-repetitive 20-MHz pulses.

  7. LC-HR-MS/MS standard urine screening approach: Pros and cons of automated on-line extraction by turbulent flow chromatography versus dilute-and-shoot and comparison with established urine precipitation.

    PubMed

    Helfer, Andreas G; Michely, Julian A; Weber, Armin A; Meyer, Markus R; Maurer, Hans H

    2017-02-01

    Comprehensive urine screening for drugs and metabolites by LC-HR-MS/MS using Orbitrap technology has been described with precipitation as simple workup. In order to fasten, automate, and/or simplify the workup, on-line extraction by turbulent flow chromatography and a dilute-and-shoot approach were developed and compared. After chromatographic separation within 10min, the Q-Exactive mass spectrometer was run in full scan mode with positive/negative switching and subsequent data dependent acquisition mode. The workup approaches were validated concerning selectivity, recovery, matrix effects, process efficiency, and limits of identification and detection for typical drug representatives and metabolites. The total workup time for on-line extraction was 6min, for the dilution approach 3min. For comparison, the established urine precipitation and evaporation lasted 10min. The validation results were acceptable. The limits for on-line extraction were comparable with those described for precipitation, but lower than for dilution. Thanks to the high sensitivity of the LC-HR-MS/MS system, all three workup approaches were sufficient for comprehensive urine screening and allowed fast, reliable, and reproducible detection of cardiovascular drugs, drugs of abuse, and other CNS acting drugs after common doses. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Evaluation of human muscle hardness after dynamic exercise with ultrasound real-time tissue elastography: a feasibility study.

    PubMed

    Yanagisawa, O; Niitsu, M; Kurihara, T; Fukubayashi, T

    2011-09-01

    To assess the feasibility of ultrasound real-time tissue elastography (RTE) for measuring exercise-induced changes in muscle hardness and to compare the findings of RTE with those of a tissue hardness meter for semi-quantitative assessment of the hardness of exercised muscles. Nine male participants performed an arm-curl exercise. RTE measurements were performed by manually applying repetitive compression with the transducer on the scan position before exercise, immediately after exercise, and at 30 min after exercise; strain ratios between muscle and a reference material (hydrogel) were calculated (muscle strain/material strain). A tissue hardness meter was also used to evaluate muscle hardness. The intraclass correlation coefficients (ICCs) for the three repeated measurements at each measurement time were calculated to evaluate the intra-observer reproducibility of each technique. Immediately after exercise, the strain ratio and the value obtained using the tissue hardness meter significantly decreased (from 1.65 to 1.35) and increased (from 51.8 to 54.3), respectively. Both parameters returned to their pre-exercise value 30 min after exercise. The ICCs of the RTE (and the ICCs of the muscle hardness meter) were 0.971 (0.816) before exercise, 0.939 (0.776) immediately after exercise, and 0.959 (0.882) at 30 min after exercise. Similar to the muscle hardness meter, RTE revealed the exercise-induced changes of muscle hardness semi-quantitatively. The intra-observer reproducibility of RTE was very high at each measurement time. These findings suggest that RTE is a clinically useful technique for assessing hardness of specific exercised muscles. Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. Whole brain analysis of postmortem density changes of grey and white matter on computed tomography by statistical parametric mapping.

    PubMed

    Nishiyama, Yuichi; Kanayama, Hidekazu; Mori, Hiroshi; Tada, Keiji; Yamamoto, Yasushi; Katsube, Takashi; Takeshita, Haruo; Kawakami, Kazunori; Kitagaki, Hajime

    2017-06-01

    This study examined the usefulness of statistical parametric mapping (SPM) for investigating postmortem changes on brain computed tomography (CT). This retrospective study included 128 patients (23 - 100 years old) without cerebral abnormalities who underwent unenhanced brain CT before and after death. The antemortem CT (AMCT) scans and postmortem CT (PMCT) scans were spatially normalized using our original brain CT template, and postmortem changes of CT values (in Hounsfield units; HU) were analysed by the SPM technique. Compared with AMCT scans, 58.6 % and 98.4 % of PMCT scans showed loss of the cerebral sulci and an unclear grey matter (GM)-white matter (WM) interface, respectively. SPM analysis revealed a significant decrease in cortical GM density within 70 min after death on PMCT scans, suggesting cytotoxic brain oedema. Furthermore, there was a significant increase in the density of the WM, lenticular nucleus and thalamus more than 120 min after death. The SPM technique demonstrated typical postmortem changes on brain CT scans, and revealed that the unclear GM-WM interface on early PMCT scans is caused by a rapid decrease in cortical GM density combined with a delayed increase in WM density. SPM may be useful for assessment of whole brain postmortem changes. • The original brain CT template achieved successful normalization of brain morphology. • Postmortem changes in the brain were independent of sex. • Cortical GM density decreased rapidly after death. • WM and deep GM densities increased following cortical GM density change. • SPM could be useful for assessment of whole brain postmortem changes.

  10. Radioaerosol lung clearance in patients with active pulmonary sarcoidosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobs, M.P.; Baughman, R.P.; Hughes, J.

    1985-05-01

    Pulmonary radioaerosol clearance rate of /sup 99m/Tc diethylenetriamine pentacetate (DTPA) in 14 patients with untreated sarcoidosis was compared with /sup 67/Ga lung scan and increased lymphocytes in the bronchoalveolar lavage (BAL) fluid. Nine healthy nonsmoking subjects had a mean DTPA clearance rate of 1.18%/min (range, 0.54 to 1.60%/min). Eight of 14 patients with sarcoidosis had clearance rates greater than 1.60%/min. Of those 8 patients with abnormal DTPA clearance, 4 had positive gallium scans, 4 had more than 17% lymphocytes in the BAL fluid, and 3 had both tests positive. To study the cause of abnormal DTPA clearance, 23 subjects (includingmore » 3 normal controls, all 14 patients with sarcoidosis, and 6 patients with localized disease on chest roentgenogram) underwent both DTPA clearance studies and BAL for quantitation of the amount of albumin in lung fluid. There was a positive correlation between the rate of DTPA clearance and the albumin concentration in lung fluid (r = 0.87, p less than 0.01).« less

  11. LSD-induced entropic brain activity predicts subsequent personality change.

    PubMed

    Lebedev, A V; Kaelen, M; Lövdén, M; Nilsson, J; Feilding, A; Nutt, D J; Carhart-Harris, R L

    2016-09-01

    Personality is known to be relatively stable throughout adulthood. Nevertheless, it has been shown that major life events with high personal significance, including experiences engendered by psychedelic drugs, can have an enduring impact on some core facets of personality. In the present, balanced-order, placebo-controlled study, we investigated biological predictors of post-lysergic acid diethylamide (LSD) changes in personality. Nineteen healthy adults underwent resting state functional MRI scans under LSD (75µg, I.V.) and placebo (saline I.V.). The Revised NEO Personality Inventory (NEO-PI-R) was completed at screening and 2 weeks after LSD/placebo. Scanning sessions consisted of three 7.5-min eyes-closed resting-state scans, one of which involved music listening. A standardized preprocessing pipeline was used to extract measures of sample entropy, which characterizes the predictability of an fMRI time-series. Mixed-effects models were used to evaluate drug-induced shifts in brain entropy and their relationship with the observed increases in the personality trait openness at the 2-week follow-up. Overall, LSD had a pronounced global effect on brain entropy, increasing it in both sensory and hierarchically higher networks across multiple time scales. These shifts predicted enduring increases in trait openness. Moreover, the predictive power of the entropy increases was greatest for the music-listening scans and when "ego-dissolution" was reported during the acute experience. These results shed new light on how LSD-induced shifts in brain dynamics and concomitant subjective experience can be predictive of lasting changes in personality. Hum Brain Mapp 37:3203-3213, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. High-resolution whole-brain diffusion MRI at 7T using radiofrequency parallel transmission.

    PubMed

    Wu, Xiaoping; Auerbach, Edward J; Vu, An T; Moeller, Steen; Lenglet, Christophe; Schmitter, Sebastian; Van de Moortele, Pierre-François; Yacoub, Essa; Uğurbil, Kâmil

    2018-03-30

    Investigating the utility of RF parallel transmission (pTx) for Human Connectome Project (HCP)-style whole-brain diffusion MRI (dMRI) data at 7 Tesla (7T). Healthy subjects were scanned in pTx and single-transmit (1Tx) modes. Multiband (MB), single-spoke pTx pulses were designed to image sagittal slices. HCP-style dMRI data (i.e., 1.05-mm resolutions, MB2, b-values = 1000/2000 s/mm 2 , 286 images and 40-min scan) and data with higher accelerations (MB3 and MB4) were acquired with pTx. pTx significantly improved flip-angle detected signal uniformity across the brain, yielding ∼19% increase in temporal SNR (tSNR) averaged over the brain relative to 1Tx. This allowed significantly enhanced estimation of multiple fiber orientations (with ∼21% decrease in dispersion) in HCP-style 7T dMRI datasets. Additionally, pTx pulses achieved substantially lower power deposition, permitting higher accelerations, enabling collection of the same data in 2/3 and 1/2 the scan time or of more data in the same scan time. pTx provides a solution to two major limitations for slice-accelerated high-resolution whole-brain dMRI at 7T; it improves flip-angle uniformity, and enables higher slice acceleration relative to current state-of-the-art. As such, pTx provides significant advantages for rapid acquisition of high-quality, high-resolution truly whole-brain dMRI data. © 2018 International Society for Magnetic Resonance in Medicine.

  13. Contrast Enhanced Diagnostic Ultrasound Causes Renal Tissue Damage in a Porcine Model

    PubMed Central

    Miller, Douglas L.; Dou, Chunyan; Wiggins, Roger C.

    2010-01-01

    Objective Glomerular capillary hemorrhage (GCH) has been reported and confirmed as a consequence of contrast-enhanced diagnostic ultrasound (CEDUS) of rat kidney. This study assessed renal tissue injury in the larger porcine model. Methods The right kidneys of anesthetized pigs were imaged in 8 groups of 4 pigs. A Vingmed System Five (General Electric Co. Cincinnati OH) was used at 1.5 MHz in B-mode to intermittently scan the kidney at 4 s intervals. A Sequoia 512 (Acuson, Mountain View CA) was used in the 1.5 MHz Cadence CPS mode with intermittent agent-clearance bursts at 4 s intervals. Kidneys were scanned transabdominally, or after laparotomy through a saline standoff. The Sequoia 512 probe was placed in contact with the kidney for one group. Definity (Lantheus Medical Imaging, N. Billerica, MA) was infused at 4 μl/kg/min (diluted 33:1 in saline) for 4 min during scanning. Results Blood-filled urinary tubules were evident on the kidney surface for all groups, except for the group with the probe in contact with the kidney. GCH was found by histology in 31.7 % ± 9.8 % of glomeruli in the center of the scan plane for 1.7 MPa transabdominal scanning and 1.5 % ± 2.9 % of glomeruli in sham samples (P<0.05). In addition, hematuria was detected after scanning, and tubular obstruction occurred in some nephrons. Conclusion Renal tissue damage was induced by CEDUS in the porcine model. This result, together with previous studies in rats, support an hypothesis that GCH would occur in humans from similar CEDUS. PMID:20876892

  14. Social Laughter Triggers Endogenous Opioid Release in Humans.

    PubMed

    Manninen, Sandra; Tuominen, Lauri; Dunbar, Robin I; Karjalainen, Tomi; Hirvonen, Jussi; Arponen, Eveliina; Hari, Riitta; Jääskeläinen, Iiro P; Sams, Mikko; Nummenmaa, Lauri

    2017-06-21

    The size of human social networks significantly exceeds the network that can be maintained by social grooming or touching in other primates. It has been proposed that endogenous opioid release after social laughter would provide a neurochemical pathway supporting long-term relationships in humans (Dunbar, 2012), yet this hypothesis currently lacks direct neurophysiological support. We used PET and the μ-opioid-receptor (MOR)-specific ligand [ 11 C]carfentanil to quantify laughter-induced endogenous opioid release in 12 healthy males. Before the social laughter scan, the subjects watched laughter-inducing comedy clips with their close friends for 30 min. Before the baseline scan, subjects spent 30 min alone in the testing room. Social laughter increased pleasurable sensations and triggered endogenous opioid release in thalamus, caudate nucleus, and anterior insula. In addition, baseline MOR availability in the cingulate and orbitofrontal cortices was associated with the rate of social laughter. In a behavioral control experiment, pain threshold-a proxy of endogenous opioidergic activation-was elevated significantly more in both male and female volunteers after watching laughter-inducing comedy versus non-laughter-inducing drama in groups. Modulation of the opioidergic activity by social laughter may be an important neurochemical pathway that supports the formation, reinforcement, and maintenance of human social bonds. SIGNIFICANCE STATEMENT Social contacts are vital to humans. The size of human social networks significantly exceeds the network that can be maintained by social grooming in other primates. Here, we used PET to show that endogenous opioid release after social laughter may provide a neurochemical mechanism supporting long-term relationships in humans. Participants were scanned twice: after a 30 min social laughter session and after spending 30 min alone in the testing room (baseline). Endogenous opioid release was stronger after laughter versus the baseline scan. Opioid receptor density in the frontal cortex predicted social laughter rates. Modulation of the opioidergic activity by social laughter may be an important neurochemical mechanism reinforcing and maintaining social bonds between humans. Copyright © 2017 the authors 0270-6474/17/376125-07$15.00/0.

  15. 18F-FPYBF-2, a new F-18 labelled amyloid imaging PET tracer: biodistribution and radiation dosimetry assessment of first-in-man 18F-FPYBF-2 PET imaging.

    PubMed

    Nishii, Ryuichi; Higashi, Tatsuya; Kagawa, Shinya; Okuyama, Chio; Kishibe, Yoshihiko; Takahashi, Masaaki; Okina, Tomoko; Suzuki, Norio; Hasegawa, Hiroshi; Nagahama, Yasuhiro; Ishizu, Koichi; Oishi, Naoya; Kimura, Hiroyuki; Watanabe, Hiroyuki; Ono, Masahiro; Saji, Hideo; Yamauchi, Hiroshi

    2018-05-01

    Recently, a benzofuran derivative for the imaging of β-amyloid plaques, 5-(5-(2-(2-(2- 18 F-fluoroethoxy)ethoxy)ethoxy)benzofuran-2-yl)- N-methylpyridin-2-amine ( 18 F-FPYBF-2) has been validated as a tracer for amyloid imaging and it was found that 18 F-FPYBF-2 PET/CT is a useful and reliable diagnostic tool for the evaluation of AD (Higashi et al. Ann Nucl Med, https://doi.org/10.1007/s12149-018-1236-1 , 2018). The aim of this study was to assess the biodistribution and radiation dosimetry of diagnostic dosages of 18 F-FPYBF-2 in normal healthy volunteers as a first-in-man study. Four normal healthy volunteers (male: 3, female: 1; mean age: 40 ± 17; age range 25-56) were included and underwent 18 F-FPYBF-2 PET/CT study for the evaluation of radiation exposure and pharmacokinetics. A 10-min dynamic PET/CT scan of the body (chest and abdomen) was performed at 0-10 min and a 15-min whole-body static scan was performed six times after the injection of 18 F-FPYBF-2. After reconstructing PET and CT image data, individual organ time-activity curves were estimated by fitting volume of interest data from the dynamic scan and whole-body scans. The OLINDA/EXM version 2.0 software was used to determine the whole-body effective doses. Dynamic PET imaging demonstrated that the hepatobiliary and renal systems were the principal pathways of clearance of 18 F-FPYBF-2. High uptake in the liver and the gall bladder, the stomach, and the kidneys were demonstrated, followed by the intestines and the urinary bladder. The ED for the adult dosimetric model was estimated to be 8.48 ± 1.25 µSv/MBq. The higher absorbed doses were estimated for the liver (28.98 ± 12.49 and 36.21 ± 15.64 µGy/MBq), the brain (20.93 ± 4.56 and 23.05 ± 5.03µ Gy/MBq), the osteogenic cells (9.67 ± 1.67 and 10.29 ± 1.70 µGy/MBq), the small intestines (9.12 ± 2.61 and 11.12 ± 3.15 µGy/MBq), and the kidneys (7.81 ± 2.62 and 8.71 ± 2.90 µGy/MBq) for male and female, respectively. The ED for the adult dosimetric model was similar to those of other agents used for amyloid PET imaging. The diagnostic dosage of 185-370 MBq of 18 F-FPYBF-2 was considered to be acceptable for administration in patients as a diagnostic tool for the evaluation of AD.

  16. Diagnostic System for Decomposition Studies of Energetic Materials

    DTIC Science & Technology

    2017-10-03

    transition states and reaction pathways are sought. The overall objective for these combined experimental studies and quantum mechanics investigations...peak-to-peak 1 min: 50,000:1 ( 8.6×10-6 AU noise) peak-to-peak Interferometer UltraScan linear air bearing scanner with True -Alignment Aperture... True 24 bit dynamic range for all scan velocities, dual channel data acquisition Validation Internal validation unit, 6 positions, certified

  17. Effect of fluoride sodium mouthwash solutions on cpTI: evaluation of physicochemical properties.

    PubMed

    Toniollo, Marcelo Bighetti; Galo, Rodrigo; Macedo, Ana Paula; Rodrigues, Renata Cristina Silveira; Ribeiro, Ricardo Faria; Mattos, Maria da Gloria Chiarello de

    2012-01-01

    The effects of fluoride, which is present in different oral hygiene products, deserve more investigation because little is known about their impact on the surface of titanium, which is largely used in Implantology. This study evaluated the surface of commercially pure titanium (cpTi) after exposure to different concentrations of sodium fluoride (NaF). The hypothesis tested in this study was that different concentrations of NaF applied at different time intervals can affect the titanium surface in different ways. The treatments resulted in the following groups: GA (control): immersion in distilled water; GB: immersion in 0.05% NaF for 3 min daily; GC: immersion in 0.2% NaF for 3 min daily; GD: immersion in 0.05% NaF for 3 min every 2 weeks; and GE: immersion in 0.2% NaF for 3 min every 2 weeks. The experiment lasted 60 days. Roughness was measured initially and every 15 days subsequently up to 60 days. After 60 days, corrosion analysis and anodic polarization were done. The samples were examined by scanning electron microscopy (SEM). The roughness data were analyzed by ANOVA and there was no significant difference among groups and among time intervals. The corrosion data (i(corr)) were analyzed by the Mann-Whitney test, and significant differences were found between GA and GC, GB and GC, GC and GD, GC and GE. SEM micrographs showed that the titanium surface exposed to NaF presented corrosion that varied with the different concentrations. This study suggests that the use of 0.05% NaF solution on cpTi is safe, whereas the 0.2% NaF solution should be carefully evaluated with regard to its daily use.

  18. Exercise Capacity and Response to Training Quantitative Trait Loci in a NZW X 129S1 Intercross and Combined Cross Analysis of Inbred Mouse Strains

    PubMed Central

    Massett, Michael P.; Avila, Joshua J.; Kim, Seung Kyum

    2015-01-01

    Genetic factors determining exercise capacity and the magnitude of the response to exercise training are poorly understood. The aim of this study was to identify quantitative trait loci (QTL) associated with exercise training in mice. Based on marked differences in training responses in inbred NZW (-0.65 ± 1.73 min) and 129S1 (6.18 ± 3.81 min) mice, a reciprocal intercross breeding scheme was used to generate 285 F2 mice. All F2 mice completed an exercise performance test before and after a 4-week treadmill running program, resulting in an increase in exercise capacity of 1.54 ± 3.69 min (range = -10 to +12 min). Genome-wide linkage scans were performed for pre-training, post-training, and change in run time. For pre-training exercise time, suggestive QTL were identified on Chromosomes 5 (57.4 cM, 2.5 LOD) and 6 (47.8 cM, 2.9 LOD). A significant QTL for post-training exercise capacity was identified on Chromosome 5 (43.4 cM, 4.1 LOD) and a suggestive QTL on Chromosomes 1 (55.7 cM, 2.3 LOD) and 8 (66.1 cM, 2.2 LOD). A suggestive QTL for the change in run time was identified on Chromosome 6 (37.8 cM, 2.7 LOD). To identify shared QTL, this data set was combined with data from a previous F2 cross between B6 and FVB strains. In the combined cross analysis, significant novel QTL for pre-training exercise time and change in exercise time were identified on Chromosome 12 (54.0 cM, 3.6 LOD) and Chromosome 6 (28.0 cM, 3.7 LOD), respectively. Collectively, these data suggest that combined cross analysis can be used to identify novel QTL and narrow the confidence interval of QTL for exercise capacity and responses to training. Furthermore, these data support the use of larger and more diverse mapping populations to identify the genetic basis for exercise capacity and responses to training. PMID:26710100

  19. Application of portable gas detector in point and scanning method to estimate spatial distribution of methane emission in landfill.

    PubMed

    Lando, Asiyanthi Tabran; Nakayama, Hirofumi; Shimaoka, Takayuki

    2017-01-01

    Methane from landfills contributes to global warming and can pose an explosion hazard. To minimize these effects emissions must be monitored. This study proposed application of portable gas detector (PGD) in point and scanning measurements to estimate spatial distribution of methane emissions in landfills. The aims of this study were to discover the advantages and disadvantages of point and scanning methods in measuring methane concentrations, discover spatial distribution of methane emissions, cognize the correlation between ambient methane concentration and methane flux, and estimate methane flux and emissions in landfills. This study was carried out in Tamangapa landfill, Makassar city-Indonesia. Measurement areas were divided into basic and expanded area. In the point method, PGD was held one meter above the landfill surface, whereas scanning method used a PGD with a data logger mounted on a wire drawn between two poles. Point method was efficient in time, only needed one person and eight minutes in measuring 400m 2 areas, whereas scanning method could capture a lot of hot spots location and needed 20min. The results from basic area showed that ambient methane concentration and flux had a significant (p<0.01) positive correlation with R 2 =0.7109 and y=0.1544 x. This correlation equation was used to describe spatial distribution of methane emissions in the expanded area by using Kriging method. The average of estimated flux from scanning method was 71.2gm -2 d -1 higher than 38.3gm -2 d -1 from point method. Further, scanning method could capture the lower and higher value, which could be useful to evaluate and estimate the possible effects of the uncontrolled emissions in landfill. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Noncontrast Peripheral MRA with Spiral Echo Train Imaging

    PubMed Central

    Fielden, Samuel W.; Mugler, John P.; Hagspiel, Klaus D.; Norton, Patrick T.; Kramer, Christopher M.; Meyer, Craig H.

    2015-01-01

    Purpose To develop a spin echo train sequence with spiral readout gradients with improved artery–vein contrast for noncontrast angiography. Theory Venous T2 becomes shorter as the echo spacing is increased in echo train sequences, improving contrast. Spiral acquisitions, due to their data collection efficiency, facilitate long echo spacings without increasing scan times. Methods Bloch equation simulations were performed to determine optimal sequence parameters, and the sequence was applied in five volunteers. In two volunteers, the sequence was performed with a range of echo times and echo spacings to compare with the theoretical contrast behavior. A Cartesian version of the sequence was used to compare contrast appearance with the spiral sequence. Additionally, spiral parallel imaging was optionally used to improve image resolution. Results In vivo, artery–vein contrast properties followed the general shape predicted by simulations, and good results were obtained in all stations. Compared with a Cartesian implementation, the spiral sequence had superior artery–vein contrast, better spatial resolution (1.2 mm2 versus 1.5 mm2), and was acquired in less time (1.4 min versus 7.5 min). Conclusion The spiral spin echo train sequence can be used for flow-independent angiography to generate threedimensional angiograms of the periphery quickly and without the use of contrast agents. PMID:24753164

  1. Human dental pulp stem cell adhesion and detachment in polycaprolactone electrospun scaffolds under direct perfusion

    PubMed Central

    Paim, A.; Braghirolli, D.I.; Cardozo, N.S.M.; Pranke, P.; Tessaro, I.C.

    2018-01-01

    Cell adhesion in three-dimensional scaffolds plays a key role in tissue development. However, stem cell behavior in electrospun scaffolds under perfusion is not fully understood. Thus, an investigation was made on the effect of flow rate and shear stress, adhesion time, and seeding density under direct perfusion in polycaprolactone electrospun scaffolds on human dental pulp stem cell detachment. Polycaprolactone scaffolds were electrospun using a solvent mixture of chloroform and methanol. The viable cell number was determined at each tested condition. Cell morphology was analyzed by confocal microscopy after various incubation times for static cell adhesion with a high seeding density. Scanning electron microscopy images were obtained before and after perfusion for the highest flow rate tested. The wall pore shear stress was calculated for all tested flow rates (0.005–3 mL/min). An inversely proportional relationship between adhesion time with cell detachment under perfusion was observed. Lower flow rates and lower seeding densities reduced the drag of cells by shear stress. However, there was an operational limit for the lowest flow rate that can be used without compromising cell viability, indicating that a flow rate of 0.05 mL/min might be more suitable for the tested cell culture in electrospun scaffolds under direct perfusion. PMID:29590258

  2. Water dynamics and retrogradation of ultrahigh pressurized wheat starch.

    PubMed

    Doona, Christopher J; Feeherry, Florence E; Baik, Moo-Yeol

    2006-09-06

    The water dynamics and retrogradation kinetics behavior of gelatinized wheat starch by either ultrahigh pressure (UHP) processing or heat are investigated. Wheat starch completely gelatinized in the condition of 90, 000 psi at 25 degrees C for 30 min (pressurized gel) or 100 degrees C for 30 min (heated gel). The physical properties of the wheat starches were characterized in terms of proton relaxation times (T2 times) measured using time-domain nuclear magnetic resonance spectroscopy and evaluated using commercially available continuous distribution modeling software. Different T2 distributions in both micro- and millisecond ranges between pressurized and heated wheat starch gels suggest distinctively different water dynamics between pressurized and heated wheat starch gels. Smaller water self-diffusion coefficients were observed for pressurized wheat starch gels and are indicative of more restricted translational proton mobility than is observed with heated wheat starch gels. The physical characteristics associated with changes taking place during retrogradation were evaluated using melting curves obtained with differential scanning calorimetry. Less retrogradation was observed in pressurized wheat starch, and it may be related to a smaller quantity of freezable water in pressurized wheat starch. Starches comprise a major constituent of many foods proposed for commercial potential using UHP, and the present results furnish insight into the effect of UHP on starch gelatinization and the mechanism of retrogradation during storage.

  3. Concentration and time-dependent effect of initial sodium hypochlorite on the ability of QMix and ethylenediaminetetraacetic acid to remove smear layer.

    PubMed

    Aksel, Hacer; Serper, Ahmet

    2017-01-01

    The aim of this study was to compare the ability of 17% ethylenediaminetetraacetic acid (EDTA) and QMix with different concentrations and time exposures of initial sodium hypochlorite (NaOCl) to remove the smear layer from the root canals. Eighty maxillary central incisors were used. After instrumentation, the teeth were divided into eight experimental groups according to the initial and final rinse. About 2.5% and 5% NaOCl were used during instrumentation and for 1 or 3 min was used as postinstrumentation initial irrigants, and 17% EDTA and QMix used as final irrigants. The apical and middle parts of the specimens were observed by scanning electron microscope. Data were analyzed using the Kruskal-Wallis, Mann-Whitney, and Friedman's test. Regardless of the type of final irrigant, QMix allowed more smear layer removal than EDTA after using 5% initial NaOCl for 3 min. In the apical part of the root canal walls, the smear layer was not completely removed. QMix and EDTA were similarly effective in smear layer removal at the middle parts of the root canal regardless of the concentration and time exposure of initial NaOCl, while none of the irrigation protocols was able to remove smear layer at the apical parts.

  4. Noncontrast peripheral MRA with spiral echo train imaging.

    PubMed

    Fielden, Samuel W; Mugler, John P; Hagspiel, Klaus D; Norton, Patrick T; Kramer, Christopher M; Meyer, Craig H

    2015-03-01

    To develop a spin echo train sequence with spiral readout gradients with improved artery-vein contrast for noncontrast angiography. Venous T2 becomes shorter as the echo spacing is increased in echo train sequences, improving contrast. Spiral acquisitions, due to their data collection efficiency, facilitate long echo spacings without increasing scan times. Bloch equation simulations were performed to determine optimal sequence parameters, and the sequence was applied in five volunteers. In two volunteers, the sequence was performed with a range of echo times and echo spacings to compare with the theoretical contrast behavior. A Cartesian version of the sequence was used to compare contrast appearance with the spiral sequence. Additionally, spiral parallel imaging was optionally used to improve image resolution. In vivo, artery-vein contrast properties followed the general shape predicted by simulations, and good results were obtained in all stations. Compared with a Cartesian implementation, the spiral sequence had superior artery-vein contrast, better spatial resolution (1.2 mm(2) versus 1.5 mm(2) ), and was acquired in less time (1.4 min versus 7.5 min). The spiral spin echo train sequence can be used for flow-independent angiography to generate three-dimensional angiograms of the periphery quickly and without the use of contrast agents. © 2014 Wiley Periodicals, Inc.

  5. Dynamic cooling during laser skin welding

    NASA Astrophysics Data System (ADS)

    Fried, Nathaniel M.; Walsh, Joseph T., Jr.

    1999-06-01

    Cryogen spray cooling of the tissue surface was investigated for laser welding applications. Benefits include reduced thermal damage to the papillary dermis and reduced operation time. Two-cm-long, full-thickness incisions were made on the backs of guinea pigs, in vivo. India ink was used as an absorber and clamps were used to appose the incision edges. Continuous-wave, 1.06-μm, Nd:YAG laser radiation was scanned over the incisions, producing ~100 ms pulses. A 4-mm-diameter laser spot was used with a constant power of 16 W. The total operation time was 60 or 120 s. Cryogen was delivered in spurt durations of 20, 60, or 100 ms, with 2 or 4 s between spurts. The working distance was approximately 12 cm, and the spray covered an area of about 5.0 x 5.0 cm. Control welds were irradiated for 20, 40, or 60 s. Total operation times were reduced from 10 min without dynamic cooling to 1 min with dynamic cooling. Optimal tensile strength was 1.7 +/- 0.7 kg/cm2, comparible to stengths of 2.1 +/- 0.7 kg/cm2 reported in previous studies without cryogen cooling (p>0.25). Thermal damage in the papillary dermis measured 320 +/- 80 μm.

  6. Effects of smelting parameters on the slag/metal separation behaviors of Hongge vanadium-bearing titanomagnetite metallized pellets obtained from the gas-based direct reduction process

    NASA Astrophysics Data System (ADS)

    Feng, Cong; Chu, Man-sheng; Tang, Jue; Liu, Zheng-gen

    2018-06-01

    Smelting separations of Hongge vanadium-bearing titanomagnetite metallized pellets (HVTMP) prepared by gas-based direct reduction were investigated, and the effects of smelting parameters on the slag/metal separation behaviors were analyzed. Relevant mechanisms were elucidated using X-ray diffraction analysis, FACTSAGE 7.0 calculations, and scanning electron microscopy observations. The results show that, when the smelting temperature, time, and C/O ratio are increased, the recoveries of V and Cr of HVTMP in pig iron are improved, the recovery of Fe initially increases and subsequently decreases, and the recovery of TiO2 in slag decreases. When the smelting CaO/SiO2 ratio is increased, the recoveries of Fe, V, and Cr in pig iron increase and the recovery of TiO2 in slag initially increases and subsequently decreases. The appropriate smelting separation parameters for HVTMP are as follows: smelting temperature of 1873 K; smelting time of 30-50 min; C/O ratio of 1.25; and CaO/SiO2 ratio of 0.50. With these optimized parameters (smelting time: 30 min), the recoveries of Fe, V, Cr, and TiO2 are 99.5%, 91.24%, 92.41%, and 94.86%, respectively.

  7. Robot-assisted laparoscopic transperitoneal infrarenal lymphadenectomy in patients with locally advanced cervical cancer by single docking: Do we need a backup procedure?

    PubMed

    Gucer, Fatih; Misirlioglu, Selim; Ceydeli, Nuri; Taskiran, Cagatay

    2018-03-01

    To present our initial experience on the feasibility of robotic transperitoneal para-aortic lymphadenectomy up to left renal vein via single docking approach by high port insertion technique followed by left shoulder docking as a rescue backup procedure in surgically obstructed patients undergoing surgical staging because of locally advanced cervical cancer (LACC). Prospective observational preliminary study. Canadian Task Force classification II-3. Tertiary-care academic affiliated private hospital. Ten patients with LACC who underwent robotic transperitoneal infrarenal para-aortic lymphadenectomy between January 2012 and December 2014. All patients with pathologically proven cervical cancer underwent a PET/CT scanning in a similar fashion at the department of nuclear medicine. PET/CT scans were evaluated by the nuclear medicine specialist. Following pre-operative work-up, robot-assisted transperitoneal infrarenal para-aortic lymphadenectomy was performed up to left renal vein by the same experienced surgeon. Sections of 5 mm were performed and stained with routine hematoxylin and eosin (H&E), and node count was done separately by experienced gynecopathologist. During the study period, 12 consecutive patients with LACC were counseled for pre-therapeutic robot-assisted transperitoneal para-aortic lymphadenectomy. Two patients declined the procedure and underwent standardized chemo-radiation therapy whereas remaining ten patients constituted the study group. In the study group, the median age was 46 years (range 33-59 years), and the median body mass index 28.5 kg/m 2 (range 18.5-35.1 kg/m 2 ). Clinical staging was stage IIB in four patients, IIIB in four, and IVA in one. Histopathological diagnosis was squamous cell carcinoma in nine patients, and adenocarcinoma in one. On PET/CT scans, seven out of ten patients were positive for pelvic lymph node metastasis. With respect to para-aortic area, only one of the ten patients had suspected metastasis in PET/CT. For nine patients with LACC, the median docking time was 6.5 min (range 4-15 min), and the median operating time for para-aortic lymphadenectomy was 120 min (range 60-165 min). The median trocar time was 14.5 min (range 5-45 min). In two out of ten patients, the surgical removal of whole lymphatic tissue between inferior mesenteric artery and left renal vein was not completely possible by a single docking of robotic column. Therefore, a new optic trocar was placed in the umbilicus and the robotic column was relocated over the left shoulder of the patient and residual lymphatic tissue measuring approximately 2 cm in the long axis immediately below the left renal vein was removed and the surgery was completed up to the left renal vein. All para-aortic lymphadenectomies have been completed by robotic route. There were no intra-operative complications. No patient received a blood transfusion. Early post-operative grade 2 and 3a complications according to Dindo classification occurred in two patients: one symptomatic lymphocyst and one local infection on assistant port site in one patient. The patient with suspected para-aortic lymph node metastasis in PET/CT showed no metastatic disease on histopathologic exam of para-aortic lymph nodes. The patient with recurrent disease and negative para-aortic lymph nodes on frozen section examination underwent robot-assisted total pelvic exenteration. Five of the residual eight patients had histologically proven metastasis in the para-aortic lymph node(s). Treatment modification occurred in six patients related to pre-treatment staging surgery. According to pathological results, extended field radiation therapy has been added in five patients and it was omitted in one patient. The median time interval between surgery and initiation of radiotherapy was 12 days (range 6-23 days). Robotic transperitoneal infrarenal para-aortic lymphadenectomy up to left renal vein by high port insertion technique is a safe and feasible option for staging and treatment planning. However, technically, it is obstructed in a small group of patients and nodal staging surgery up to left renal vein can be completed by consecutive left shoulder docking approach as a backup rescue plan.

  8. A phase II, single-blind, randomized, crossover evaluation of the safety and efficacy of avanafil using visual sexual stimulation in patients with mild to moderate erectile dysfunction.

    PubMed

    Hellstrom, Wayne J G; Freier, Matthew T; Serefoglu, Ege Can; Lewis, Ronald W; DiDonato, Karen; Peterson, Craig A

    2013-01-01

    To evaluate the safety, efficacy and time course of three doses of avanafil (50 mg, 100 mg and 200 mg) compared with sildenafil 50 mg or placebo, given in conjunction with visual sexual stimulation (VSS) videos in men with mild to moderate erectile dysfunction (ED). Male patients, 35-70 years of age, with mild to moderate ED of ≥6 months duration, were included in the study. During the course of the study, each patient received placebo, active control (sildenafil 50 mg), and one dose of avanafil (50 mg, 100 mg or 200 mg), all administered in random order at least 72 h apart. RigiScan® (Dacomed Corp., Minneapolis, MN, USA) monitoring was used in conjunction with 20-min VSS videos (20, 60, and 100 min after dosing) to determine the duration of and time to ≥60% penile rigidity, maximum rigidity, tumescent activity units (TAUs), rigidity activity units (RAUs), and responses to the five-point Erection Assessment Scale. Safety assessments included adverse events (AEs), vital sign changes in response to dosing, laboratory results (complete blood counts, chemistry panel, prostate-specific antigen, serum testosterone, prothrombin time and urine analysis) and physical examination findings. Eighty-three patients were randomized and received at least one dose of study medication; 82 patients completed the study. Peak response to avanafil occurred in the early interval (20-40 min after dosing), while peak response to sildenafil occurred either in the middle (60-80 min) or late (100-120 min) intervals after dosing. Results were qualitatively similar for all other efficacy endpoints. During the 20-40-min interval, the majority of values for TAUs and RAUs with the avanafil 50-mg, 100-mg and 200-mg treatments were significantly superior to placebo (P < 0.05). Avanafil treatment was generally well tolerated; facial flushing (7-15%) was the most commonly observed AE, and no visual disturbances were reported. A favourable safety profile and improvement in sexual function, coupled with rapid onset of action and durability of effect, make avanafil an attractive option for males with ED, especially in the setting of on-demand treatment. © 2012 BJU International.

  9. Surface recombination velocity imaging of wet-cleaned silicon wafers using quantitative heterodyne lock-in carrierography

    NASA Astrophysics Data System (ADS)

    Sun, Qiming; Melnikov, Alexander; Mandelis, Andreas; Pagliaro, Robert H.

    2018-01-01

    InGaAs-camera based heterodyne lock-in carrierography (HeLIC) is developed for surface recombination velocity (SRV) imaging characterization of bare (oxide-free) hydrogen passivated Si wafer surfaces. Samples prepared using four different hydrofluoric special-solution etching conditions were tested, and a quantitative assessment of their surface quality vs. queue-time after the hydrogen passivation process was made. The data acquisition time for an SRV image was about 3 min. A "round-trip" frequency-scan mode was introduced to minimize the effects of signal transients on data self-consistency. Simultaneous best fitting of HeLIC amplitude-frequency dependencies at various queue-times was used to guarantee the reliability of resolving surface and bulk carrier recombination/transport properties. The dynamic range of the measured SRV values was established from 0.1 to 100 m/s.

  10. Construction of super - hydrophobic copper alloy surface by one - step mixed solution immersion method

    NASA Astrophysics Data System (ADS)

    Gu, Qiang; Chen, Ying; Chen, Dong; Zhang, Zeting

    2018-01-01

    This paper presents a method for preparing a super hydrophobic surface with a fast, simple, low-cost, one-step reaction by immersing copper alloy in an ethanol solution containing silver nitrate and myristic acid. The effects of reaction time, reaction temperature, reactant concentration and reaction time on the wettability of the material were studied. The surface wettability, appearance, chemical composition, durability and chemical stability of the prepared samples was measured by water contact angle (CA), scanning electron microscopy (SEM), energy dispersive spectrometer (EDS), X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR). The results show that when the reaction time is only 10min, the surface WCA of the prepared material can reach 154.9. This study provides an effective method for the rapid preparation of stable super hydrophobic surfaces.

  11. [Rapid 3-Dimensional Models of Cerebral Aneurysm for Emergency Surgical Clipping].

    PubMed

    Konno, Takehiko; Mashiko, Toshihiro; Oguma, Hirofumi; Kaneko, Naoki; Otani, Keisuke; Watanabe, Eiju

    2016-08-01

    We developed a method for manufacturing solid models of cerebral aneurysms, with a shorter printing time than that involved in conventional methods, using a compact 3D printer with acrylonitrile-butadiene-styrene(ABS)resin. We further investigated the application and utility of this printing system in emergency clipping surgery. A total of 16 patients diagnosed with acute subarachnoid hemorrhage resulting from cerebral aneurysm rupture were enrolled in the present study. Emergency clipping was performed on the day of hospitalization. Digital Imaging and Communication in Medicine(DICOM)data obtained from computed tomography angiography(CTA)scans were edited and converted to stereolithography(STL)file formats, followed by the production of 3D models of the cerebral aneurysm by using the 3D printer. The mean time from hospitalization to the commencement of surgery was 242 min, whereas the mean time required for manufacturing the 3D model was 67 min. The average cost of each 3D model was 194 Japanese Yen. The time required for manufacturing the 3D models shortened to approximately 1 hour with increasing experience of producing 3D models. Favorable impressions for the use of the 3D models in clipping were reported by almost all neurosurgeons included in this study. Although 3D printing is often considered to involve huge costs and long manufacturing time, the method used in the present study requires shorter time and lower costs than conventional methods for manufacturing 3D cerebral aneurysm models, thus making it suitable for use in emergency clipping.

  12. Study of thermomechanical treatment on mechanical-induced phase transformation of NiTi and TiNiCu wires.

    PubMed

    Seyyed Aghamiri, S M; Nili Ahmadabadi, M; Shahmir, H; Naghdi, F; Raygan, Sh

    2013-05-01

    The nickel-titanium shape memory alloys have been used in orthodontic application due to their unique properties like superelasticity and biocompatibility. The phase transformation behavior of these alloys can be changed by alloying elements and thermomechanical processing conditions. In this study, two types of NiTi and TiNiCu wires of 0.4mm diameter were produced via thermomechanical treatments with final step of 20% cold drawing followed by annealing at different temperatures of 300 and 400 °C for varying times of 10, 30 and 60 min. The processed wires were characterized by oral cavity configuration three point bending (OCTPB) test at 37 °C to specify the mechanical transformation features. Also, differential scanning calorimetry (DSC) was used to analyze the thermal transformation temperatures of selected wires. The results showed the thermomechanical treatment at 300 °C for 30 min was the suitable process in terms of superelasticity and transformation temperatures for orthodontic application. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Homogeneous alignment of nematic liquid crystals by ion beam etched surfaces

    NASA Technical Reports Server (NTRS)

    Wintucky, E. G.; Mahmood, R.; Johnson, D. L.

    1979-01-01

    A wide range of ion beam etch parameters capable of producing uniform homogeneous alignment of nematic liquid crystals on SiO2 films are discussed. The alignment surfaces were generated by obliquely incident (angles of 5 to 25 deg) argon ions with energies in the range of 0.5 to 2.0 KeV, ion current densities of 0.1 to 0.6 mA sq cm and etch times of 1 to 9 min. A smaller range of ion beam parameters (2.0 KeV, 0.2 mA sq cm, 5 to 10 deg and 1 to 5 min.) were also investigated with ZrO2 films and found suitable for homogeneous alignment. Extinction ratios were very high (1000), twist angles were small ( or = 3 deg) and tilt-bias angles very small ( or = 1 deg). Preliminary scanning electron microscopy results indicate a parallel oriented surface structure on the ion beam etched surfaces which may determine alignment.

  14. Highly porous solid-phase microextraction fiber coating based on poly(ethylene glycol)-modified ormosils synthesized by sol-gel technology.

    PubMed

    da Costa Silva, Raquel Gomes; Augusto, Fabio

    2005-04-22

    The preparation and characteristics of solid-phase microextraction (SPME) fibers coated with Carbowax 20M ormosil (organically modified silica) are described here. Raw fused silica fibers were coated with Carbowax 20M-modified silica using sol-gel process. Scanning electron micrographs of fibers revealed a highly porous, sponge-like coating with an average thickness of (8 +/- 1) microm. The sol-gel Carbowax fibers were compared to commercial fibers coated with 100 microm polydimethylsiloxane (PDMS) and 65 microm Carbowax-divinylbenzene (DVB). Shorter equilibrium times were possible with the sol-gel Carbowax fiber: for headspace extraction of the test analytes, they ranged from less than 3 min for benzene to 15 min for o-xylene. Extraction efficiencies of the sol-gel Carbowax fiber were superior to those of conventional fibers: for o-xylene, the extracted masses were 230 and 540% of that obtained with 100 microm PDMS and 65 microm Carbowax-DVB fibers, respectively.

  15. Selective Extraction of Flavonoids from Sophora flavescens Ait. by Mechanochemistry.

    PubMed

    Zhang, Qihong; Yu, Jingbo; Wang, Yingyao; Su, Weike

    2016-07-29

    Flavonoids from Sophora flavescens were selectively extracted by mechanochemical-promoted extraction technology (MPET) after using response surface methodology to determine the optimal extraction parameters. The highest yield of 35.17 mg/g was achieved by grinding the roots with Na₂CO₃ (15%) at 440 rpm/min for 17.0 min and water was used as the sole solvent with a ratio of solvent to solid material of 25 mL/g. Flavonoids prepared by MPET demonstrated relatively higher antioxidant activities in subsequent DPPH and hydroxyl radical scavenging assays. Main constituents in the extracts, including kurarinol, kushenol I/N and kurarinone, were characterized by HPLC-MS/MS, indicating good selective extraction by MPET. Physicochemical property changes of powder during mechanochemical milling were identified by scanning electron microscopy, X-ray powder diffraction, and UV-Vis diffuse-reflectance spectroscopy. Compared with traditional extraction methods, MPET possesses notable advantages of higher selectivity, lower extraction temperature, shorter extraction time, and organic solvent free properties.

  16. Preparation of poly-o-phenylenediamine/TiO 2/fly-ash cenospheres and its photo-degradation property on antibiotics

    NASA Astrophysics Data System (ADS)

    Huo, Pengwei; Yan, Yongsheng; Li, Songtian; Li, Huaming; Huang, Weihong

    2010-03-01

    A series of poly-o-phenylenediamine/TiO 2/fly-ash cenospheres(POPD/TiO 2/fly-ash cenospheres) composites have been prepared from o-phenylenediamine and TiO 2/fly-ash cenospheres under various polymerization conditions. The properties of the samples were characterized by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), specific surface area (BET), X-ray diffraction (XRD), Fourier transform infrared (FT-IR) and UV-vis diffuse reflectance spectrum (UV-vis DRS). Photocatalytic activity was studied by degradation of antibiotics waste water under visible light. The results indicate that the photo-induced method is viable for preparing modified photocatalysts, and the modified photocatalysts have good absorption in visible light range. The photocatalysts of POPD/TiO 2/fly-ash cenospheres which have good performance are prepared at pH 3 and 4, and the polymerized time around 40 min. When the photocatalysts are prepared under the conditions of pH 3 and polymerized time 40 min, the degradation rate of roxithromycin waste water could reach near 60%, and it indicates that the way of POPD modified TiO 2/fly-ash cenospheres to degrade the antibiotics waste water is viable.

  17. Synthesis and characterization of nanocrystalline Al 2024-B4C composite powders by mechanical alloying

    NASA Astrophysics Data System (ADS)

    Varol, T.; Canakci, A.

    2013-06-01

    In the present work, the effect of milling parameters on the morphology and microstructure of nanostructure Al2024-B4C composite powders obtained by mechanical alloying (MA) was studied. The effects of milling time and B4C content on the morphology, microstructure and particle size of nanostructure Al2024-B4C composite powders have been investigated. Different amounts of B4C particles (0, 5, 10 and 20 wt.%) were mixed with Al2024 powders and milled in a planetary ball mill for 30, 60, 120, 300, 420 and 600 min. Al 2024-B4C composite powders were characterized using a scanning electron microscope (SEM), laser particle-size analyzer, X-ray diffraction analysis (XRD) and the Vickers microhardness test. The results showed that the nanostructure Al2024-B4C composite powders were produced when they were milled for 600 min. The size of composite powder in the milled powder mixture was affected by the milling time and content of B4C particles. Moreover, it was observed that when MA reached a steady state, the properties of composite powders were stabilized.

  18. Optimization of banana trunk-activated carbon production for methylene blue-contaminated water treatment

    NASA Astrophysics Data System (ADS)

    Danish, Mohammed; Ahmad, Tanweer; Nadhari, W. N. A. W.; Ahmad, Mehraj; Khanday, Waheed Ahmad; Ziyang, Lou; Pin, Zhou

    2018-03-01

    This experiment was run to characterize the banana trunk-activated carbon through methylene blue dye adsorption property. The H3PO4 chemical activating agent was used to produce activated carbons from the banana trunk. A small rotatable central composite design of response surface methodology was adopted to prepare chemically (H3PO4) activated carbon from banana trunk. Three operating variables such as activation time (50-120 min), activation temperature (450-850 °C), and activating agent concentration (1.5-7.0 mol/L) play a significant role in the adsorption capacities ( q) of activated carbons against methylene blue dye. The results implied that the maximum adsorption capacity of fixed dosage (4.0 g/L) banana trunk-activated carbon was achieved at the activation time of 51 min, the activation temperature of 774 °C, and H3PO4 concentration of 5.09 mol/L. At optimum conditions of preparation, the obtained banana trunk-activated carbon has adsorption capacity 64.66 mg/g against methylene blue. Among the prepared activated carbons run number 3 (prepared with central values of the operating variables) was characterized through Fourier transform infrared spectroscopy, field emission scanning microscopy, and powder X-ray diffraction.

  19. Evaluation of lung clearance of inhaled pertechnegas.

    PubMed

    Fanti, S; Compagnone, G; Pancaldi, D; Franchi, R; Corbelli, C; Marengo, M; Onofri, C; Galassi, R; Levorato, M; Monetti, N

    1996-02-01

    Pertechnegas is a new ventilation agent produced by modifying the atmosphere of combustion of Technegas. Due to its rapid disappearance from the lungs, Pertechnegas has been suggested as useful in measuring pulmonary epithelial permeability. This study aimed to assess the reliability of ventilation scans with Pertechnegas to evaluate alveolar-capillary permeability. Six non-smokers with no evidence of pulmonary disease were investigated. Scintigraphic data were used to evaluate the site of Pertechnegas deposition (by assessing the Penetration Index [PI] of the gas), its clearance rate (by calculating the time to half-clearance [T1/2]) and its lung distribution (by means of a pixel-by-pixel analysis. PI measurements produced a mean value of 88.8 +/- 13.3% (range 69-117%). Time activity curves showed a fast clearance in all cases (mean T1/2 = 10.7 +/- 2.1 min, range 8.1-14.3 min). Comparison of statistical indices of uniform deposition (skewness and kurtosis) indicated satisfactory homogeneity of Pertechnegas distribution throughout the lungs. These data show that after inhalation Pertechnegas has a peripheral deposition and a homogeneous distribution in the lungs and is rapidly cleared through the alveolar-capillary barrier. In conclusion Pertechnegas can be recommended as a potential radiopharmaceutical for studying the pulmonary epithelial barrier.

  20. DSC, X-ray and FTIR studies of a gemfibrozil/dimethyl-β-cyclodextrin inclusion complex produced by co-grinding.

    PubMed

    Aigner, Z; Berkesi, O; Farkas, G; Szabó-Révész, P

    2012-01-05

    The steps of formation of an inclusion complex produced by the co-grinding of gemfibrozil and dimethyl-β-cyclodextrin were investigated by differential scanning calorimetry (DSC), X-ray powder diffractometry (XRPD) and Fourier transform infrared (FTIR) spectroscopy with curve-fitting analysis. The endothermic peak at 59.25°C reflecting the melting of gemfibrozil progressively disappeared from the DSC curves of the products on increase of the duration of co-grinding. The crystallinity of the samples too gradually decreased, and after 35min of co-grinding the product was totally amorphous. Up to this co-grinding time, XRPD and FTIR investigations indicated a linear correlation between the cyclodextrin complexation and the co-grinding time. After co-grinding for 30min, the ratio of complex formation did not increase. These studies demonstrated that co-grinding is a suitable method for the complexation of gemfibrozil with dimethyl-β-cyclodextrin. XRPD analysis revealed the amorphous state of the gemfibrozil-dimethyl-β-cyclodextrin product. FTIR spectroscopy with curve-fitting analysis may be useful as a semiquantitative analytical method for discriminating the molecular and amorphous states of gemfibrozil. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Photocatalytic degradation of an azo textile dye (C.I. Reactive Red 195 (3BF)) in aqueous solution over copper cobaltite nanocomposite coated on glass by Doctor Blade method.

    PubMed

    Habibi, Mohammad Hossein; Rezvani, Zoya

    2015-08-05

    The degradation of C.I. Reactive Red 195 (3BF) in aqueous solution using copper cobaltite nanocomposite coated on glass by Doctor Blade method was studied. Structural, optical and morphological properties of nanocomposite coatings were characterized by X-ray powder diffractometry (XRD), diffuse reflectance spectroscopy (DRS) and field emission scanning electron microscopy (FESEM). The nanoparticles exhibit a particle size of 31 nm, showing a good nanoscale crystalline morphology. The photocatalytic activity of copper cobaltite nanocomposite coated on glass was studied by performing the photocatalytic degradation of 3BF at different irradiation time. The effect of irradiation time on the degradation of 3BF was studied and the results showed that more than 85% of the 3BF was degraded in 45 min of irradiation. The pseudo-first-order kinetic models were used and the rate constants were evaluated with pseudo first order rate constants of 4.10 × 10(-2) min(-1). The main advantage of the photocatalyst coated on glass overcomes the difficulties in separation and recycle of photocatalyst suspensions. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Laterality of foetal self-touch in relation to maternal stress.

    PubMed

    Reissland, Nadja; Aydin, Ezra; Francis, Brian; Exley, Kendra

    2015-01-01

    This longitudinal observational study investigated whether foetuses change their hand preference with gestational age, and also examined the effects of maternal stress on lateralized foetal self-touch. Following ethical approval, fifteen healthy foetuses (eight girls and seven boys) were scanned four times from 24 to 36 weeks gestation. Self-touch behaviours which resulted in a touch of the foetal face/head were coded in 60 scans for 10 min and analysed in terms of frequency of the foetuses using left and right hands to touch their face. The joint effects of foetal age, stress and sex on laterality were assessed. We modelled the proportion of right self-touches for each foetal scan using a generalized linear mixed model, taking account of the repeated measures design. There was substantial variability in hand preference between foetuses. However, there was no significant increase in the proportion of right-handed touches with foetal age. No sex differences in handedness were identified. However, maternally reported stress level was significantly positively related to foetal left-handed self-touches (odds ratio 0.915; p < .0001). This longitudinal study provides important new insights into the effect of recent maternal stress on foetal predominant hand use during self-touch.

  3. Synthesis and Characterization of Reduced Graphene Oxide-Supported Nanoscale Zero-Valent Iron (nZVI/rGO) Composites Used for Pb(II) Removal

    PubMed Central

    Fan, Mingyi; Li, Tongjun; Hu, Jiwei; Cao, Rensheng; Wu, Qing; Wei, Xionghui; Li, Lingyun; Shi, Xuedan; Ruan, Wenqian

    2016-01-01

    Reduced graphene oxide-supported nanoscale zero-valent iron (nZVI/rGO) composites were prepared by chemical deposition method and were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), Raman spectroscopy, N2-sorption and X-ray photoelectron spectroscopy (XPS). Operating parameters for the removal process of Pb(II) ions, such as temperature (20–40 °C), pH (3–5), initial concentration (400–600 mg/L) and contact time (20–60 min), were optimized using a quadratic model. The coefficient of determination (R2 > 0.99) obtained for the mathematical model indicates a high correlation between the experimental and predicted values. The optimal temperature, pH, initial concentration and contact time for Pb(II) ions removal in the present experiment were 21.30 °C, 5.00, 400.00 mg/L and 60.00 min, respectively. In addition, the Pb(II) removal by nZVI/rGO composites was quantitatively evaluated by using adsorption isotherms, such as Langmuir and Freundlich isotherm models, of which Langmuir isotherm gave a better correlation, and the calculated maximum adsorption capacity was 910 mg/g. The removal process of Pb(II) ions could be completed within 50 min, which was well described by the pseudo-second order kinetic model. Therefore, the nZVI/rGO composites are suitable as efficient materials for the advanced treatment of Pb(II)-containing wastewater. PMID:28773813

  4. Synthesis and Characterization of Reduced Graphene Oxide-Supported Nanoscale Zero-Valent Iron (nZVI/rGO) Composites Used for Pb(II) Removal.

    PubMed

    Fan, Mingyi; Li, Tongjun; Hu, Jiwei; Cao, Rensheng; Wu, Qing; Wei, Xionghui; Li, Lingyun; Shi, Xuedan; Ruan, Wenqian

    2016-08-12

    Reduced graphene oxide-supported nanoscale zero-valent iron (nZVI/rGO) composites were prepared by chemical deposition method and were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), Raman spectroscopy, N₂-sorption and X-ray photoelectron spectroscopy (XPS). Operating parameters for the removal process of Pb(II) ions, such as temperature (20-40 °C), pH (3-5), initial concentration (400-600 mg/L) and contact time (20-60 min), were optimized using a quadratic model. The coefficient of determination ( R ² > 0.99) obtained for the mathematical model indicates a high correlation between the experimental and predicted values. The optimal temperature, pH, initial concentration and contact time for Pb(II) ions removal in the present experiment were 21.30 °C, 5.00, 400.00 mg/L and 60.00 min, respectively. In addition, the Pb(II) removal by nZVI/rGO composites was quantitatively evaluated by using adsorption isotherms, such as Langmuir and Freundlich isotherm models, of which Langmuir isotherm gave a better correlation, and the calculated maximum adsorption capacity was 910 mg/g. The removal process of Pb(II) ions could be completed within 50 min, which was well described by the pseudo-second order kinetic model. Therefore, the nZVI/rGO composites are suitable as efficient materials for the advanced treatment of Pb(II)-containing wastewater.

  5. Short-scan-time multi-slice diffusion MRI of the mouse cervical spinal cord using echo planar imaging.

    PubMed

    Callot, Virginie; Duhamel, Guillaume; Cozzone, Patrick J; Kober, Frank

    2008-10-01

    Mouse spinal cord (SC) diffusion-weighted imaging (DWI) provides important information on tissue morphology and structural changes that may occur during pathologies such as multiple sclerosis or SC injury. The acquisition scheme of the commonly used DWI techniques is based on conventional spin-echo encoding, which is time-consuming. The purpose of this work was to investigate whether the use of echo planar imaging (EPI) would provide good-quality diffusion MR images of mouse SC, as well as accurate measurements of diffusion-derived metrics, and thus enable diffusion tensor imaging (DTI) and highly resolved DWI within reasonable scan times. A four-shot diffusion-weighted spin-echo EPI (SE-EPI) sequence was evaluated at 11.75 T on a group of healthy mice (n = 10). SE-EPI-derived apparent diffusion coefficients of gray and white matter were compared with those obtained using a conventional spin-echo sequence (c-SE) to validate the accuracy of the method. To take advantage of the reduction in acquisition time offered by the EPI sequence, multi-slice DTI acquisitions were performed covering the cervical segments (six slices, six diffusion-encoding directions, three b values) within 30 min (vs 2 h for c-SE). From these measurements, fractional anisotropy and mean diffusivities were calculated, and fiber tracking along the C1 to C6 cervical segments was performed. In addition, high-resolution images (74 x 94 microm(2)) were acquired within 5 min per direction. Clear delineation of gray and white matter and identical apparent diffusion coefficient values were obtained, with a threefold reduction in acquisition time compared with c-SE. While overcoming the difficulties associated with high spatially and temporally resolved DTI measurements, the present SE-EPI approach permitted identification of reliable quantitative parameters with a reproducibility compatible with the detection of pathologies. The SE-EPI method may be particularly valuable when multiple sets of images from the SC are needed, in cases of rapidly evolving conditions, to decrease the duration of anesthesia or to improve MR exploration by including additional MR measurements. Copyright (c) 2008 John Wiley & Sons, Ltd.

  6. Comparison of propofol and dexmedetomedine techniques in children undergoing magnetic resonance imaging.

    PubMed

    Wu, Junzheng; Mahmoud, Mohamed; Schmitt, Megan; Hossain, Md; Kurth, Dean

    2014-08-01

    Propofol (PRO) and dexmedetomidine (DEX) are commonly used to produce anesthesia and sedation for routine MRI procedures. Children with complex conditions often require much lengthy MRI for multi-body-part scans with frequent scanner coil changes and patient body reposition. This study compared PRO and DEX techniques on outcomes for the particular MRI setting with longer than 1 h duration. 95 children, aged from 1 to 7 years, scheduled for MRI >75 min were randomly assigned to PRO or DEX group. After induced with sevoflurane, a loading dose of PRO (2 mg·kg(-1)) was administrated and followed by continuous infusion (200 μg·kg(-1) ·min(-1)); a loading dose of DEX (2 μg·kg(-1)) was administrated and followed by continuous infusion (2 μg·kg(-1) ·h(-1)). Patients received O(2) by nasal cannula. The observed outcomes were times for induction, MRI, emergence, and recovery, and total time (induction to discharge); MRI pauses from patient movement; incidence of technique failure and critical events; emergence and behavior in postanesthesia care unit (PACU); parental satisfaction; and arterial pressure (BP) and heart rate (HR) during anesthesia. PRO compared with DEX showed significantly less time for anesthesia induction (16.3 versus 24.2 min), emergence (21.2 versus 39.9 min), PACU (35.7 versus 62.5 min), and total time (135 versus 173 min) (all P < 0.001). There were significantly fewer pauses during MRI and lower failure rate to complete MRI in PRO versus DEX (0.22 versus 0.81, P = 0.01 and 1 versus 15, P < 0.001), less behavioral disturbances in PACU, and higher parental satisfaction in PRO versus DEX (P < 0.01). There were no critical events in either group: In PRO, mean BP during MRI (from 52 ± 8 to 58 ± mmHg) was significantly less than before anesthesia (80 ± 12 mmHg), while HR remained relatively constant (range of 97-103) at its baseline of 108 ± 21, but in DEX, mean BP remained unchanged (from 76 ± 12 to 78 ± 15) during anesthesia compared with before anesthesia (79 ± 14 mmHg), while HR decreased (74 ± 16 to 78 ± 15) during anesthesia from its baseline (102 ± 17). For children undergoing lengthy multicomponent MRI, the propofol technique yielded overall better outcomes than the dexmedetomedine technique in terms of timeliness, PACU emergence characteristics, and parental satisfaction. © 2014 John Wiley & Sons Ltd.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paudel, Nava Raj, E-mail: nrpaudel@yahoo.com; Shvydka, Diana; Parsai, E. Ishmael

    Purpose: Gold nanoparticles (GNPs) are known to be effective mediators in microwave hyperthermia. Interaction with an electromagnetic field, large surface to volume ratio, and size quantization of nanoparticles (NPs) can lead to increased cell killing beyond pure heating effects. The purpose of this study is to explore the possibility of free radical generation by GNPs in aqueous media when they are exposed to a microwave field. Methods: A number of samples with 500 mM 5,5-dimethyl-1-pyrroline N-oxide (DMPO) in 20 ppm GNP colloidal suspensions were scanned with an electron paramagnetic resonance (EPR)/electron spin resonance spectrometer to generate and detect free radicals.more » A fixed (9.68 GHz) frequency microwave from the spectrometer has served for both generation and detection of radicals. EPR spectra obtained as first derivatives of intensity with the spectrometer were double integrated to get the free radical signal intensities. Power dependence of radical intensity was studied by applying various levels of microwave power (12.5, 49.7, and 125 mW) while keeping all other scan parameters the same. Free radical signal intensities from initial and final scans, acquired at the same power levels, were compared. Results: Hydroxyl radical (OH⋅) signal was found to be generated due to the exposure of GNP–DMPO colloidal samples to a microwave field. Intensity of OH⋅ signal thus generated at 12.5 mW microwave power for 2.8 min was close to the intensity of OH⋅ signal obtained from a water–DMPO sample exposed to 1.5 Gy ionizing radiation dose. For repeated scans, higher OH⋅ intensities were observed in the final scan for higher power levels applied between the initial and the final scans. Final intensities were higher also for a shorter time interval between the initial and the final scans. Conclusions: Our results observed for the first time demonstrate that GNPs generate OH⋅ radicals in aqueous media when they are exposed to a microwave field. If OH⋅ radicals can be generated close to deoxyribonucleic acid of cells by proper localization of NPs, NP-aided microwave hyperthermia can yield cell killing via both elevated temperature and free radical generation.« less

  8. A novel property of gold nanoparticles: Free radical generation under microwave irradiation.

    PubMed

    Paudel, Nava Raj; Shvydka, Diana; Parsai, E Ishmael

    2016-04-01

    Gold nanoparticles (GNPs) are known to be effective mediators in microwave hyperthermia. Interaction with an electromagnetic field, large surface to volume ratio, and size quantization of nanoparticles (NPs) can lead to increased cell killing beyond pure heating effects. The purpose of this study is to explore the possibility of free radical generation by GNPs in aqueous media when they are exposed to a microwave field. A number of samples with 500 mM 5,5-dimethyl-1-pyrroline N-oxide (DMPO) in 20 ppm GNP colloidal suspensions were scanned with an electron paramagnetic resonance (EPR)/electron spin resonance spectrometer to generate and detect free radicals. A fixed (9.68 GHz) frequency microwave from the spectrometer has served for both generation and detection of radicals. EPR spectra obtained as first derivatives of intensity with the spectrometer were double integrated to get the free radical signal intensities. Power dependence of radical intensity was studied by applying various levels of microwave power (12.5, 49.7, and 125 mW) while keeping all other scan parameters the same. Free radical signal intensities from initial and final scans, acquired at the same power levels, were compared. Hydroxyl radical (OH⋅) signal was found to be generated due to the exposure of GNP-DMPO colloidal samples to a microwave field. Intensity of OH⋅ signal thus generated at 12.5 mW microwave power for 2.8 min was close to the intensity of OH⋅ signal obtained from a water-DMPO sample exposed to 1.5 Gy ionizing radiation dose. For repeated scans, higher OH⋅ intensities were observed in the final scan for higher power levels applied between the initial and the final scans. Final intensities were higher also for a shorter time interval between the initial and the final scans. Our results observed for the first time demonstrate that GNPs generate OH⋅ radicals in aqueous media when they are exposed to a microwave field. If OH⋅ radicals can be generated close to deoxyribonucleic acid of cells by proper localization of NPs, NP-aided microwave hyperthermia can yield cell killing via both elevated temperature and free radical generation.

  9. Correlative fluorescence and electron microscopy of quantum dot labeled proteins on whole cells in liquid.

    PubMed

    Peckys, Diana B; Dukes, Madeline J; de Jonge, Niels

    2014-01-01

    Correlative fluorescence microscopy and scanning transmission electron microscopy (STEM) of cells fully immersed in liquid is a new methodology with many application areas. Proteins, in live cells immobilized on microchips, are labeled with fluorescent quantum dot (QD) nanoparticles. In this protocol, the epidermal growth factor receptor (EGFR) is labeled. The cells are fixed after a selected labeling time, for example, 5 min as needed to form EGFR dimers. The microchip with cells is then imaged with fluorescence microscopy. Thereafter, the microchip with the labeled cells and one with a spacer are assembled in a special microfluidic device and imaged with STEM.

  10. One-trocar-assisted pyeloplasty: An attractive alternative to open pyeloplasty

    PubMed Central

    Marte, Antonio; Papparella, Alfonso

    2015-01-01

    Background: To survey the effects of one-trocar-assisted pyeloplasty (OTAP) in the treatment of ureteropelvic junction obstruction (UPJO) in kids. Materials and Methods: Forty-four children (±3.5 years) were submitted to OTAP procedure. A flank incision under the XII rib was made, the Gerota's fascia was achieved and a balloon Hasson trocar with an operative telescope inserted for retroperitoneal access. The renal pelvis and ureter were isolated and exteriorised. Forty-two patients underwent Anderson-Hynes dismembered and one Fenger pyeloplasty. One patient was converted to an open procedure. Two patients presented an aberrant crossing vessel. In all patients, a double J stent was positioned. The operative time and length of stay (LOS) were evaluated. Renal scan and ultrasound (US) were utilised to evaluate the results from 6 to 12 months. Results: OTAP was successful in all but 1 patient. Mean operative time and LOS were 128 min and 3,5 days. We had four operative complications (9.09%). The US and a nuclear scan confirmed the resolution of the UPJO in all patients except one with the Fenger pyeloplasty who had an open Anderson-Hynes. Conclusions: The combination of retroperitoneoscopic and open procedures for dismembered pyeloplasty offers a simple, time-saving method in a minimally invasive fashion with low morbidity for patients with UPJO. PMID:26712293

  11. One-trocar-assisted pyeloplasty: An attractive alternative to open pyeloplasty.

    PubMed

    Marte, Antonio; Papparella, Alfonso

    2015-01-01

    To survey the effects of one-trocar-assisted pyeloplasty (OTAP) in the treatment of ureteropelvic junction obstruction (UPJO) in kids. Forty-four children (±3.5 years) were submitted to OTAP procedure. A flank incision under the XII rib was made, the Gerota's fascia was achieved and a balloon Hasson trocar with an operative telescope inserted for retroperitoneal access. The renal pelvis and ureter were isolated and exteriorised. Forty-two patients underwent Anderson-Hynes dismembered and one Fenger pyeloplasty . One patient was converted to an open procedure. Two patients presented an aberrant crossing vessel. In all patients, a double J stent was positioned. The operative time and length of stay (LOS) were evaluated. Renal scan and ultrasound (US) were utilised to evaluate the results from 6 to 12 months. OTAP was successful in all but 1 patient. Mean operative time and LOS were 128 min and 3,5 days. We had four operative complications (9.09%). The US and a nuclear scan confirmed the resolution of the UPJO in all patients except one with the Fenger pyeloplasty who had an open Anderson-Hynes. The combination of retroperitoneoscopic and open procedures for dismembered pyeloplasty offers a simple, time-saving method in a minimally invasive fashion with low morbidity for patients with UPJO.

  12. Value of non-contrast sequences in magnetic resonance angiography of hepatic arterial vasculature.

    PubMed

    Kalra, Vivek B; Gilbert, John W; Krishnamoorthy, Saravanan; Cornfeld, Daniel

    2014-06-01

    To evaluate value of adding non-contrast MR angiographic sequence (In-Flow Inversion Recovery [IFIR]) to standard fat-suppressed T1-weighted postcontrast sequence (3D spoiled gradient echo [3D-GRE]) for evaluating hepatic arterial anatomy. Retrospective evaluation of 30 consecutive patients undergoing multiphase liver MRI. Individual vessels for IFIR/3D-GRE sequences were evaluated by two blinded readers using a four-point scale. Statistical analysis was performed using the Wilcoxon signed-rank test for vessel conspicuity between IFIR/3D-GRE sequences. IFIR alone diagnostically imaged 8.1% of vessels, 3D-GRE alone 25.8%, 55.8% by both 3D-GRE/IFIR, and 10.3% of vessels by neither. Two patients with variant vascular anatomy were visualized with both sequences. Addition of IFIR to 3D-GRE resulted in statistically significant increase in arterial visualization (p<0.001), 10% relative increase in identified vessels, and 3-5 mi increase in acquisition time for total scan time of 30-35 min. IFIR may be a useful adjunct to 3D-GRE in hepatic angiography without adding considerably to scan time. 10% more hepatic arteries were seen when combining information from IFIR/3D-GRE vs. 3D-GRE alone. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Isolation and characterization of nanocrystalline cellulose from roselle-derived microcrystalline cellulose.

    PubMed

    Kian, Lau Kia; Jawaid, Mohammad; Ariffin, Hidayah; Karim, Zoheb

    2018-07-15

    Roselle fiber is a renewable and sustainable agricultural waste enriched with cellulose polysaccharides. The isolation of Nanocrystalline cellulose (NCC) from roselle-derived microcrystalline cellulose (MCC) is an alternative approach to recover the agricultural roselle plant residue. In the present study, acid hydrolysis with different reaction time was carried out to degrade the roselle-derived MCC to form NCC. The characterizations of isolated NCC were conducted through Fourier Transform Infrared Ray (FTIR), Transmission Electron Microscopy (TEM), Field Emission Scanning Electron Microscopy (FESEM), Atomic Force Microscopy (AFM), Dynamic Light Scattering (DLS), Energy Dispersive Spectroscopy (EDS), X-ray Diffraction (XRD), Thermogravimetric Analysis (TGA) and Differential Scanning Calorimetry (DSC). As evaluated from the performed morphological investigations, the needle-like shape NCC nanostructures were observed under TEM and AFM microscopy studies, while irregular rod-like shape of NCC was observed under FESEM analysis. With 60min hydrolysis time, XRD analysis demonstrated the highest NCC crystallinity degree with 79.5%. In thermal analysis by TGA and DSC, the shorter hydrolysis time tended to produce NCC with higher thermal stability. Thus, the isolated NCC from roselle-derived MCC has high potential to be used in application of pharmaceutical and biomedical fields for nanocomposite fabrication. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Remineralization Potential of Three Different Dentifrices using Raman Spectroscopy and Confocal Laser Scanning Microscope.

    PubMed

    Job, Tisson V; Narayana, Girish T; Venkappa, Kishan K; Nathan, K Binu; Ahsan, Shameem; Harikaran, Jayakkodi

    2018-04-01

    Aim: The aim of this study was to compare the remineralization potential of three different dentifrices using Raman spectroscopy and confocal laser scanning microscopy (CLSM). Materials and methods: Totally, 30 extracted intact impacted third molar teeth were selected and the crown of each tooth in a group was separated from the root and longitudinally sectioned into four parts with each section under a subgroup, of which one section was an untreated section, the second and the third sections were demineralized in a demineralizing solution, and the third section was remineralized after demineralization. The teeth in the three groups were demineralized for 4 days and then treated with 0.21% sodium fluoride dentifrice with trical-cium phosphate, casein phosphopeptide-amorphous calcium phosphate (CPP-ACP), and NovaMin for 14 days, following which the teeth surfaces were studied using Raman spec-troscopy and CLSM to assess the remineralization potential of the three dentifrices. The data were recorded and analyzed statistically. Results: Raman spectroscopic analysis revealed better remin-eralization with CPP-ACP, which was statistically significant from the groups treated with the NovaMin dentifrice and the fluoride-containing dentifrice.Confocal laser scanning microscopic examination also revealed significant differences between the three groups with the NovaMin-containing dentifrice demonstrating a greater remineralization of the surface when compared with the CPP-ACP dentifrice. The teeth samples treated with fluoride-containing dentifrice demonstrated the least reminer-alization among the three groups. Conclusion: It can be concluded that the demineralized samples of teeth treated with CPP-ACP showed the highest concentration of phosphate ions when analyzed using Raman spectroscopy, and the microscopic examination using confocal laser revealed a better surface remineralization of the demin-eralized samples when treated with the NovaMin technology. Clinical significance: There is a great need to find ways to enhance the remineralization process and transfer such knowledge into clinical therapy to alter caries balance for the better, especially in individuals with a high cariogenic bacterial challenge. Keywords: Casein phosphopeptide-amorphous calcium phosphate, Fluoride, NovaMin, Remineralization, Tricalcium phosphate.

  15. Sliding window prior data assisted compressed sensing for MRI tracking of lung tumors.

    PubMed

    Yip, Eugene; Yun, Jihyun; Wachowicz, Keith; Gabos, Zsolt; Rathee, Satyapal; Fallone, B G

    2017-01-01

    Hybrid magnetic resonance imaging and radiation therapy devices are capable of imaging in real-time to track intrafractional lung tumor motion during radiotherapy. Highly accelerated magnetic resonance (MR) imaging methods can potentially reduce system delay time and/or improves imaging spatial resolution, and provide flexibility in imaging parameters. Prior Data Assisted Compressed Sensing (PDACS) has previously been proposed as an acceleration method that combines the advantages of 2D compressed sensing and the KEYHOLE view-sharing technique. However, as PDACS relies on prior data acquired at the beginning of a dynamic imaging sequence, decline in image quality occurs for longer duration scans due to drifts in MR signal. Novel sliding window-based techniques for refreshing prior data are proposed as a solution to this problem. MR acceleration is performed by retrospective removal of data from the fully sampled sets. Six patients with lung tumors are scanned with a clinical 3 T MRI using a balanced steady-state free precession (bSSFP) sequence for 3 min at approximately 4 frames per second, for a total of 650 dynamics. A series of distinct pseudo-random patterns of partial k-space acquisition is generated such that, when combined with other dynamics within a sliding window of 100 dynamics, covers the entire k-space. The prior data in the sliding window are continuously refreshed to reduce the impact of MR signal drifts. We intended to demonstrate two different ways to utilize the sliding window data: a simple averaging method and a navigator-based method. These two sliding window methods are quantitatively compared against the original PDACS method using three metrics: artifact power, centroid displacement error, and Dice's coefficient. The study is repeated with pseudo 0.5 T images by adding complex, normally distributed noise with a standard deviation that reduces image SNR, relative to original 3 T images, by a factor of 6. Without sliding window implemented, PDACS-reconstructed dynamic datasets showed progressive increases in image artifact power as the 3 min scan progresses. With sliding windows implemented, this increase in artifact power is eliminated. Near the end of a 3 min scan at 3 T SNR and 5× acceleration, implementation of an averaging (navigator) sliding window method improves our metrics by the following ways: artifact power decreases from 0.065 without sliding window to 0.030 (0.031), centroid error decreases from 2.64 to 1.41 mm (1.28 mm), and Dice coefficient agreement increases from 0.860 to 0.912 (0.915). At pseudo 0.5 T SNR, the improvements in metrics are as follows: artifact power decreases from 0.110 without sliding window to 0.0897 (0.0985), centroid error decreases from 2.92 mm to 1.36 mm (1.32 mm), and Dice coefficient agreements increases from 0.851 to 0.894 (0.896). In this work we demonstrated the negative impact of slow changes in MR signal for longer duration PDACS dynamic scans, namely increases in image artifact power and reductions of tumor tracking accuracy. We have also demonstrated sliding window implementations (i.e., refreshing of prior data) of PDACS are effective solutions to this problem at both 3 T and simulated 0.5 T bSSFP images. © 2016 American Association of Physicists in Medicine.

  16. Obstacle Avoidance, Visual Detection Performance, and Eye-Scanning Behavior of Glaucoma Patients in a Driving Simulator: A Preliminary Study

    PubMed Central

    Prado Vega, Rocío; van Leeuwen, Peter M.; Rendón Vélez, Elizabeth; Lemij, Hans G.; de Winter, Joost C. F.

    2013-01-01

    The objective of this study was to evaluate differences in driving performance, visual detection performance, and eye-scanning behavior between glaucoma patients and control participants without glaucoma. Glaucoma patients (n = 23) and control participants (n = 12) completed four 5-min driving sessions in a simulator. The participants were instructed to maintain the car in the right lane of a two-lane highway while their speed was automatically maintained at 100 km/h. Additional tasks per session were: Session 1: none, Session 2: verbalization of projected letters, Session 3: avoidance of static obstacles, and Session 4: combined letter verbalization and avoidance of static obstacles. Eye-scanning behavior was recorded with an eye-tracker. Results showed no statistically significant differences between patients and control participants for lane keeping, obstacle avoidance, and eye-scanning behavior. Steering activity, number of missed letters, and letter reaction time were significantly higher for glaucoma patients than for control participants. In conclusion, glaucoma patients were able to avoid objects and maintain a nominal lane keeping performance, but applied more steering input than control participants, and were more likely than control participants to miss peripherally projected stimuli. The eye-tracking results suggest that glaucoma patients did not use extra visual search to compensate for their visual field loss. Limitations of the study, such as small sample size, are discussed. PMID:24146975

  17. The first clinical application of planning software for laparoscopic microwave thermosphere ablation of malignant liver tumours

    PubMed Central

    Berber, Eren

    2015-01-01

    Background Liver tumour ablation is an operator-dependent procedure. The determination of the optimum needle trajectory and correct ablation parameters could be challenging. The aim of this study was to report the utility of a new, procedure planning software for microwave ablation (MWA) of liver tumours. Methods This was a feasibility study in a pilot group of five patients with nine metastatic liver tumours who underwent laparoscopic MWA. Pre-operatively, parameters predicting the desired ablation zones were calculated for each tumour. Intra-operatively, this planning strategy was followed for both antenna placement and energy application. Post-operative 2-week computed tomography (CT) scans were performed to evaluate complete tumour destruction. Results The patients had an average of two tumours (range 1–4), measuring 1.9 ± 0.4 cm (range 0.9–4.4 cm). The ablation time was 7.1 ± 1.3 min (range 2.5–10 min) at 100W. There were no complications or mortality. The patients were discharged home on post-operative day (POD) 1. At 2-week CT scans, there were no residual tumours, with a complete ablation demonstrated in all lesions. Conclusions This study describes and validates pre-treatment planning software for MWA of liver tumours. This software was found useful to determine precisely the ablation parameters and needle placement to create a predicted zone of ablation. PMID:25980481

  18. Characterization of banana peel by scanning electron microscopy and FT-IR spectroscopy and its use for cadmium removal.

    PubMed

    Memon, Jamil R; Memon, Saima Q; Bhanger, M I; Memon, G Zuhra; El-Turki, A; Allen, Geoffrey C

    2008-10-15

    This study describes the use of banana peel, a commonly produced fruit waste, for the removal of Cd(II) from environmental and industrial wastewater. The banana peel was characterized by FT-IR and scanning electron microscopy (SEM) coupled with energy dispersive X-ray (EDX) analysis. The parameters pH, contact time, initial metal ion concentration and temperature were investigated and found to be rapid ( approximately 97% within 10 min). The Langmuir adsorption isotherm was used to describe partitioning behavior for the system at room temperature. The value of Q(L) was found to be (35.52 mg g(-1)) higher than the previously reported materials. The binding of metal ions was found to be pH-dependent with the optimal sorption occurring at pH 8. The retained species were eluted with 5 mL of 5 x 10(-3)M HNO(3) with the detection limit of 1.7 x 10(-3)mg L(-1). Kinetics of sorption followed the pseudo-first-order rate equation with the rate constant k, equal to 0.13+/-0.01 min(-1). Thermodynamic parameters such as Gibbs free energy at 303K (-7.41+/-0.13 kJ mol(-1)) and enthalpy (40.56+/-2.34 kJ mol(-1)) indicated the spontaneous and endothermic nature of the sorption process. The developed method was utilized for the removal of Cd(II) ions from environmental and industrial wastewater samples using flame atomic absorption spectrophotometer (FAAS).

  19. Stable and efficient retrospective 4D-MRI using non-uniformly distributed quasi-random numbers

    NASA Astrophysics Data System (ADS)

    Breuer, Kathrin; Meyer, Cord B.; Breuer, Felix A.; Richter, Anne; Exner, Florian; Weng, Andreas M.; Ströhle, Serge; Polat, Bülent; Jakob, Peter M.; Sauer, Otto A.; Flentje, Michael; Weick, Stefan

    2018-04-01

    The purpose of this work is the development of a robust and reliable three-dimensional (3D) Cartesian imaging technique for fast and flexible retrospective 4D abdominal MRI during free breathing. To this end, a non-uniform quasi random (NU-QR) reordering of the phase encoding (k y –k z ) lines was incorporated into 3D Cartesian acquisition. The proposed sampling scheme allocates more phase encoding points near the k-space origin while reducing the sampling density in the outer part of the k-space. Respiratory self-gating in combination with SPIRiT-reconstruction is used for the reconstruction of abdominal data sets in different respiratory phases (4D-MRI). Six volunteers and three patients were examined at 1.5 T during free breathing. Additionally, data sets with conventional two-dimensional (2D) linear and 2D quasi random phase encoding order were acquired for the volunteers for comparison. A quantitative evaluation of image quality versus scan times (from 70 s to 626 s) for the given sampling schemes was obtained by calculating the normalized mutual information (NMI) for all volunteers. Motion estimation was accomplished by calculating the maximum derivative of a signal intensity profile of a transition (e.g. tumor or diaphragm). The 2D non-uniform quasi-random distribution of phase encoding lines in Cartesian 3D MRI yields more efficient undersampling patterns for parallel imaging compared to conventional uniform quasi-random and linear sampling. Median NMI values of NU-QR sampling are the highest for all scan times. Therefore, within the same scan time 4D imaging could be performed with improved image quality. The proposed method allows for the reconstruction of motion artifact reduced 4D data sets with isotropic spatial resolution of 2.1  ×  2.1  ×  2.1 mm3 in a short scan time, e.g. 10 respiratory phases in only 3 min. Cranio-caudal tumor displacements between 23 and 46 mm could be observed. NU-QR sampling enables for stable 4D-MRI with high temporal and spatial resolution within short scan time for visualization of organ or tumor motion during free breathing. Further studies, e.g. the application of the method for radiotherapy planning are needed to investigate the clinical applicability and diagnostic value of the approach.

  20. Annexin-V/quantum dot probes for multimodal apoptosis monitoring in living cells: improving bioanalysis using electrochemistry

    NASA Astrophysics Data System (ADS)

    Montón, Helena; Parolo, Claudio; Aranda-Ramos, Antonio; Merkoçi, Arben; Nogués, Carme

    2015-02-01

    There is a great demand to develop novel techniques that allow useful and complete monitoring of apoptosis, which is a key factor of several diseases and a target for drug development. Here, we present the use of a novel dual electrochemical/optical label for the detection and study of apoptosis. We combined the specificity of Annexin-V for phosphatidylserine, a phospholipid expressed in the outer membrane of apoptotic cells, with the optical and electrochemical properties of quantum dots to create a more efficient label. Using this conjugate we addressed three important issues: (i) we made the labeling of apoptotic cells faster (30 min) and easier; (ii) we fully characterized the samples by common cell biological techniques (confocal laser scanning microscopy, scanning electron microscopy and flow cytometry); and (iii) we developed a fast, cheap and quantitative electrochemical detection method for apoptotic cells with results in full agreement with those obtained by flow cytometry.There is a great demand to develop novel techniques that allow useful and complete monitoring of apoptosis, which is a key factor of several diseases and a target for drug development. Here, we present the use of a novel dual electrochemical/optical label for the detection and study of apoptosis. We combined the specificity of Annexin-V for phosphatidylserine, a phospholipid expressed in the outer membrane of apoptotic cells, with the optical and electrochemical properties of quantum dots to create a more efficient label. Using this conjugate we addressed three important issues: (i) we made the labeling of apoptotic cells faster (30 min) and easier; (ii) we fully characterized the samples by common cell biological techniques (confocal laser scanning microscopy, scanning electron microscopy and flow cytometry); and (iii) we developed a fast, cheap and quantitative electrochemical detection method for apoptotic cells with results in full agreement with those obtained by flow cytometry. Electronic supplementary information (ESI) available: Optical microscopy images of apoptotic induced cell cultures at different times and negative control of flow cytometry. See DOI: 10.1039/c4nr07191c

  1. Immobilization of Magnetic Nanoparticles onto Amine-Modified Nano-Silica Gel for Copper Ions Remediation

    PubMed Central

    Elkady, Marwa; Hassan, Hassan Shokry; Hashim, Aly

    2016-01-01

    A novel nano-hybrid was synthesized through immobilization of amine-functionalized silica gel nanoparticles with nanomagnetite via a co-precipitation technique. The parameters, such as reagent concentrations, reaction temperature and time, were optimized to accomplish the nano-silica gel chelating matrix. The most proper amine-modified silica gel nanoparticles were immobilized with magnetic nanoparticles. The synthesized magnetic amine nano-silica gel (MANSG) was established and characterized using X-ray diffraction (XRD), transmission electron microscopy (TEM), scanning electron microscopy (SEM), Fourier transform infrared (FTIR), thermal gravimetric analysis (TGA), differential scanning calorimetry (DSC) and vibrating sample magnetometry (VSM). The feasibility of MANSG for copper ions’ remediation from wastewater was examined. MANSG achieves a 98% copper decontamination from polluted water within 90 min. Equilibrium sorption of copper ions onto MANSG nanoparticles obeyed the Langmuir equation compared to the Freundlich, Temkin, Elovich and Dubinin-Radushkevich (D-R) equilibrium isotherm models. The pseudo-second-order rate kinetics is appropriate to describe the copper sorption process onto the fabricated MANSG. PMID:28773583

  2. Three-dimensional machining of carbon nanotube forests using water-assisted scanning electron microscope processing

    NASA Astrophysics Data System (ADS)

    Rajabifar, Bahram; Kim, Sanha; Slinker, Keith; Ehlert, Gregory J.; Hart, A. John; Maschmann, Matthew R.

    2015-10-01

    We demonstrate that vertically aligned carbon nanotubes (CNTs) can be precisely machined in a low pressure water vapor ambient using the electron beam of an environmental scanning electron microscope. The electron beam locally damages the irradiated regions of the CNT forest and also dissociates the water vapor molecules into reactive species including hydroxyl radicals. These species then locally oxidize the damaged region of the CNTs. The technique offers material removal capabilities ranging from selected CNTs to hundreds of cubic microns. We study how the material removal rate is influenced by the acceleration voltage, beam current, dwell time, operating pressure, and CNT orientation. Milled cuts with depths between 0-100 microns are generated, corresponding to a material removal rate of up to 20.1 μm3/min. The technique produces little carbon residue and does not disturb the native morphology of the CNT network. Finally, we demonstrate direct machining of pyramidal surfaces and re-entrant cuts to create freestanding geometries.

  3. Three-dimensional machining of carbon nanotube forests using water-assisted scanning electron microscope processing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rajabifar, Bahram; Maschmann, Matthew R., E-mail: MaschmannM@missouri.edu; Kim, Sanha

    2015-10-05

    We demonstrate that vertically aligned carbon nanotubes (CNTs) can be precisely machined in a low pressure water vapor ambient using the electron beam of an environmental scanning electron microscope. The electron beam locally damages the irradiated regions of the CNT forest and also dissociates the water vapor molecules into reactive species including hydroxyl radicals. These species then locally oxidize the damaged region of the CNTs. The technique offers material removal capabilities ranging from selected CNTs to hundreds of cubic microns. We study how the material removal rate is influenced by the acceleration voltage, beam current, dwell time, operating pressure, andmore » CNT orientation. Milled cuts with depths between 0–100 microns are generated, corresponding to a material removal rate of up to 20.1 μm{sup 3}/min. The technique produces little carbon residue and does not disturb the native morphology of the CNT network. Finally, we demonstrate direct machining of pyramidal surfaces and re-entrant cuts to create freestanding geometries.« less

  4. Analysis of the penetration of a caffeine containing shampoo into the hair follicles by in vivo laser scanning microscopy

    NASA Astrophysics Data System (ADS)

    Lademann, J.; Richter, H.; Schanzer, S.; Klenk, A.; Sterry, W.; Patzelt, A.

    2010-02-01

    In previous in vitro investigations, it was demonstrated that caffeine is able to stimulate the hair growth. Therefore, a penetration of caffeine into the hair follicle is necessary. In the present study, in vivo laser scanning microscopy (LSM) was used to investigate the penetration and storage of a caffeine containing shampoo into the hair follicles. It was shown that a 2-min contact time of the shampoo with the skin was enough to accumulate significant parts of the shampoo in the hair follicles. A penetration of the shampoo up to a depth of approx. 200 μm could be detected, which represents the detection limit of the LSM. At this depth, the close network of the blood capillaries surrounding the hair follicles commences. Even after 24 h, the substance was still detectable in the hair follicles. This demonstrates the long-term reservoir function of the hair follicles for topically applied substances such as caffeine.

  5. Effects of micronisation and dehulling of pre-soaked bambara groundnut seeds on microstructure and functionality of the resulting flours.

    PubMed

    Ogundele, Opeolu M; Minnaar, Amanda; Emmambux, M Naushad

    2017-01-01

    Functional properties of flours from pre-soaked and micronised (130°C) whole and dehulled bambara seeds (5, 10 and 15min) were determined. An increase in micronisation time significantly reduced the pasting viscosity of the flours. Significant reductions in the differential scanning calorimetry endothermic peak enthalpies and loss of birefringence in the starch were found, indicating starch pre-gelatinisation when micronised. The low viscous paste of resultant flours seems to be related to protein denaturation as shown by decrease in nitrogen solubility index. Starch was embedded in a protein matrix as shown by confocal laser scanning microscopy. This denatured protein matrixes could be in part preventing starch hydration and dispersion during pasting and thus reduced viscosity. Dehulling reduced the pasting viscosity suggesting higher effect of micronisation for dehulled than whole samples. Resulting flours can be useful ingredients in protein energy-dense foods due to low viscosity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. The binding of the primary water of hydration to nucleosides, CsDNA and potassium hyaluronate

    NASA Astrophysics Data System (ADS)

    Lukan, A. M.; Cavanaugh, D.; Whitson, K. B.; Marlowe, R. L.; Lee, S. A.; Anthony, L.; Rupprecht, A.; Mohan, V.

    1998-03-01

    Differential scanning calorimetry (DSC) has been used to study the eight nucleosides, CsDNA and KHA hydrated at 59% relative humidity. Thermograms were measured between 25 and 180 ^oC for scan rates of 1, 2, 5, 10 and 20 K/min. A broad endothermic transition (due to the desorption of the water) near 80 ^oC was observed for all runs. The average enthalpy of desorption per water molecule was evaluated from the area under the peak. A Kissinger analysis of these data yielded the net activation energy for desorption. Both parameters were very similar for the two biopolymers. Rayleigh scattering of Mossbauer radiation (RSMR) data(G. Albanese et al. ) Hyperfine Int. 95, 97 (1995) were analyzed via a simple harmonic oscillator model to evaluate the effective force constant of the water bound to the biopolymer. This analysis suggests that the effective force constant of water bound to HA is much larger (about 5 times) than for water bound to DNA.

  7. Efficacy of cold light bleaching using different bleaching times and their effects on human enamel.

    PubMed

    Wang, Wei; Zhu, Yuhe; Li, Jiajia; Liao, Susan; Ai, Hongjun

    2013-01-01

    This study investigated the efficacy of cold light bleaching using different bleaching times and the effects thereof on tooth enamel. Before and after bleaching, stained tooth specimens were subjected to visual and instrumental colorimetric assessments using Vita Shade Guide and spectrophotometric shade matching. Enamel surface alterations were examined using scanning electron microscopy (SEM) to analyze surface morphology, surface microhardness (SMH) measurement to determine changes in mechanical properties, and X-ray diffraction (XRD) to characterize post-bleaching enamel composition. Cold light bleaching successfully improved tooth color, with optimal efficacy when bleaching time was beyond 10 min. Significant differences in surface morphology were observed among the different bleaching times, but no significant differences were observed for enamel composition and surface microhardness among the different bleaching times. Results of this study revealed an association between the bleaching time of cold light bleaching and its whitening efficacy. Together with the results on enamel surface changes, this study provided positive evidence to support cold light bleaching as an in-office bleaching treatment.

  8. Real time dynamics of Si magic clusters mediating phase transformation: Si(111)-(1 × 1) to (7 × 7) reconstruction revisited

    NASA Astrophysics Data System (ADS)

    Ong, Wei Jie; Tok, Eng Soon

    2012-07-01

    Using Scanning Tunneling Microscope (STM), we show that the surface undergoes phase transformation from disordered "1 × 1" to (7 × 7) reconstruction which is mediated by the formation of Si magic clusters. Mono-disperse Si magic clusters of size ~ 13.5 ± 0.5 Å can be formed by heating the Si(111) surface to 1200 °C and quenching it to room temperature at cooling rates of at least 100 °C/min. The structure consists of 3 tetra-clusters of size ~ 4.5 Ǻ similar to the Si magic clusters that were formed from Si adatoms deposited by Si solid source on Si(111)-(7 × 7) [1]. Using real time STM scanning to probe the surface at ~ 400 °C, we show that Si magic clusters pop up from the (1 × 1) surface and form spontaneously during the phase transformation. This is attributed to the difference in atomic density between "disordered 1 × 1" and (7 × 7) surface structures which lead to the release of excess Si atoms onto the surface as magic clusters.

  9. Application of an innovative computerized virtual planning system in acetabular fracture surgery: A feasibility study.

    PubMed

    Wang, Huixiang; Wang, Fang; Newman, Simon; Lin, Yanping; Chen, Xiaojun; Xu, Lu; Wang, Qiugen

    2016-08-01

    Acetabular fracture surgery is amongst the most challenging tasks in the field of trauma surgery and careful preoperative planning is crucial for success. The aim of this paper is to describe the preliminary outcome of the utilization of an innovative computerized virtual planning system for acetabular fractures. 3D models of acetabular fractures and surrounding soft tissues from six patients were constructed from preoperative CT scans. A novel highly-automatic segmentation technique was performed on the 3D model to separate each fracture fragment, then 3D virtual reduction was performed. Additionally, the models were used to assess potential surgical approaches with reference to both the fracture and the surrounding soft tissues. The time required for virtual planning was recorded. After surgery, the virtual plan was compared to the real surgery with respect to surgical approach and reduction sequence. A Likert scale questionnaire was completed by the surgeons to evaluate their satisfaction with the system. Virtual planning was successfully completed in all cases. The planned surgical approach was followed in all cases with the planned reduction sequence followed completely in five cases and partially in one. The mean time required for virtual planning was 38.7min (range 21-57, SD=15.5). The mean time required for planning of B-type fractures was 25.0min (range 21-30, SD=4.6), of C-type fracture 52.3min (range 49-57, SD=4.2). The results of the questionnaire demonstrated a high level of satisfaction with the planning system. This study demonstrates that the virtual planning system is feasible in clinical settings with high satisfaction and acceptability from the surgeons. It provides a viable option for the planning of acetabular fracture surgery. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Gd-EDDA/HYNIC-RGD as an MR molecular probe imaging integrin alphanubeta3 receptor-expressed tumor-MR molecular imaging of angiogenesis.

    PubMed

    Huo, Tianlong; Du, Xiangke; Zhang, Sen; Liu, Xia; Li, Xubing

    2010-02-01

    The aim of this study is to develop a novel MR probe containing arginine-glycine-aspartic acid (RGD) motif for imaging integrin alphanubeta3 receptor-expressed tumor. Commercially available HYNIC-RGD conjugated with co-ligand EDDA was labeled with Gd(3+), and the mixture was isolated and purified by solid phase extract (SPE) to get the entire probe Gd-EDDA/HYNIC-RGD. Human hepatocellular carcinoma (HHCC) cell line BEL-7402 was cultured and the cells harvested and suspended in serum-free Dulbecco's modified Eagle medium (DMEM) were subcutaneously inoculated into athymic nude mice for tumor growth. In vitro cell binding assay to integrin alphanubeta3 receptor and cell viability experiments were conducted. The in vivo imaging of the three arms of xenografts were performed by MR scan with a dedicated animal coil at time points of 0, 30, 60, 90min and 24-h post-intravenous injection (p.i.). Three arms of nude mice then were sacrificed for histological examination to confirm the imaging results. Gd-EDDA/HYNIC-RGD was successfully isolated by SPE and validity was verified on signal enhancement through in vitro and in vivo experiments. The nude mice model bearing HHCC was well established. There was approx. 30% signal enhancement on T1WI FSE images at 90min post-intravenous injection of the Gd-EDDA/HYNIC-RGD compared with baseline, and the signal to time curve is straightforward over time in the span of 0-90min p.i., while the control arms do not show this tendency. Gd-EDDA/HYNIC-RGD has the potential to serve as an MR probe detecting integrin alphanubeta3 receptor-expressed tumor. Copyright (c) 2008 Elsevier Ireland Ltd. All rights reserved.

  11. STrategically Acquired Gradient Echo (STAGE) imaging, part I: Creating enhanced T1 contrast and standardized susceptibility weighted imaging and quantitative susceptibility mapping.

    PubMed

    Chen, Yongsheng; Liu, Saifeng; Wang, Yu; Kang, Yan; Haacke, E Mark

    2018-02-01

    To provide whole brain grey matter (GM) to white matter (WM) contrast enhanced T1W (T1WE) images, multi-echo quantitative susceptibility mapping (QSM), proton density (PD) weighted images, T1 maps, PD maps, susceptibility weighted imaging (SWI), and R2* maps with minimal misregistration in scanning times <5min. Strategically acquired gradient echo (STAGE) imaging includes two fully flow compensated double echo gradient echo acquisitions with a resolution of 0.67×1.33×2.0mm 3 acquired in 5min for 64 slices. Ten subjects were recruited and scanned at 3 Tesla. The optimum pair of flip angles (6° and 24° with TR=25ms at 3T) were used for both T1 mapping with radio frequency (RF) transmit field correction and creating enhanced GM/WM contrast (the T1WE). The proposed T1WE image was created from a combination of the proton density weighted (6°, PDW) and T1W (24°) images and corrected for RF transmit field variations. Prior to the QSM calculation, a multi-echo phase unwrapping strategy was implemented using the unwrapped short echo to unwrap the longer echo to speed up computation. R2* maps were used to mask deep grey matter and veins during the iterative QSM calculation. A weighted-average sum of susceptibility maps was generated to increase the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR). The proposed T1WE image has a significantly improved CNR both for WM to deep GM and WM to cortical GM compared to the acquired T1W image (the first echo of 24° scan) and the T1MPRAGE image. The weighted-average susceptibility maps have 80±26%, 55±22%, 108±33% SNR increases across the ten subjects compared to the single echo result of 17.5ms for the putamen, caudate nucleus, and globus pallidus, respectively. STAGE imaging offers the potential to create a standardized brain imaging protocol providing four pieces of quantitative tissue property information and multiple types of qualitative information in just 5min. Published by Elsevier Inc.

  12. The evolution of computed tomography from organ-selective to whole-body scanning in managing unconscious patients with multiple trauma

    PubMed Central

    Hong, Zhi-Jie; Chen, Cheng-Jueng; Yu, Jyh-Cherng; Chan, De-Chuan; Chou, Yu-Ching; Liang, Chia-Ming; Hsu, Sheng-Der

    2016-01-01

    Abstract We aimed to evaluate the benefit of whole-body computed tomography (WBCT) scanning for unconscious adult patients suffering from high-energy multiple trauma compared with the conventional stepwise approach of organ-selective CT. Totally, 144 unconscious patients with high-energy multiple trauma from single level I trauma center in North Taiwan were enrolled from January 2009 to December 2013. All patients were managed by a well-trained trauma team and were suitable for CT examination. The enrolled patients are all transferred directly from the scene of an accident, not from other medical institutions with a definitive diagnosis. The scanning regions of WBCT include head, neck, chest, abdomen, and pelvis. We analyzed differences between non-WBCT and WBCT groups, including gender, age, hospital stay, Injury Severity Score, Glasgow Coma Scale, Revised Trauma Score, time in emergency department (ED), medical cost, and survival outcome. Fifty-five patients received the conventional approach for treating trauma, and 89 patients received immediate WBCT scanning after an initial examination. Patients’ time in ED was significantly shorter in the WBCT group in comparison with the non-WBCT group (158.62 ± 80.13 vs 216.56 ± 168.32 min, P = 0.02). After adjusting for all possible confounding factors, we also found that survival outcome of the WBCT group was better than that of the non-WBCT group (odds ratio: 0.21, 95% confidence interval: 0.06–0.75, P = 0.016). Early performing WBCT during initial trauma management is a better approach for treating unconscious patients with high-energy multiple trauma. PMID:27631215

  13. The evolution of computed tomography from organ-selective to whole-body scanning in managing unconscious patients with multiple trauma: A retrospective cohort study.

    PubMed

    Hong, Zhi-Jie; Chen, Cheng-Jueng; Yu, Jyh-Cherng; Chan, De-Chuan; Chou, Yu-Ching; Liang, Chia-Ming; Hsu, Sheng-Der

    2016-09-01

    We aimed to evaluate the benefit of whole-body computed tomography (WBCT) scanning for unconscious adult patients suffering from high-energy multiple trauma compared with the conventional stepwise approach of organ-selective CT.Totally, 144 unconscious patients with high-energy multiple trauma from single level I trauma center in North Taiwan were enrolled from January 2009 to December 2013. All patients were managed by a well-trained trauma team and were suitable for CT examination. The enrolled patients are all transferred directly from the scene of an accident, not from other medical institutions with a definitive diagnosis. The scanning regions of WBCT include head, neck, chest, abdomen, and pelvis. We analyzed differences between non-WBCT and WBCT groups, including gender, age, hospital stay, Injury Severity Score, Glasgow Coma Scale, Revised Trauma Score, time in emergency department (ED), medical cost, and survival outcome.Fifty-five patients received the conventional approach for treating trauma, and 89 patients received immediate WBCT scanning after an initial examination. Patients' time in ED was significantly shorter in the WBCT group in comparison with the non-WBCT group (158.62 ± 80.13 vs 216.56 ± 168.32 min, P = 0.02). After adjusting for all possible confounding factors, we also found that survival outcome of the WBCT group was better than that of the non-WBCT group (odds ratio: 0.21, 95% confidence interval: 0.06-0.75, P = 0.016).Early performing WBCT during initial trauma management is a better approach for treating unconscious patients with high-energy multiple trauma.

  14. 4D x-ray phase contrast tomography for repeatable motion of biological samples

    NASA Astrophysics Data System (ADS)

    Hoshino, Masato; Uesugi, Kentaro; Yagi, Naoto

    2016-09-01

    X-ray phase contrast tomography based on a grating interferometer was applied to fast and dynamic measurements of biological samples. To achieve this, the scanning procedure in the tomographic scan was improved. A triangle-shaped voltage signal from a waveform generator to a Piezo stage was used for the fast phase stepping in the grating interferometer. In addition, an optical fiber coupled x-ray scientific CMOS camera was used to achieve fast and highly efficient image acquisitions. These optimizations made it possible to perform an x-ray phase contrast tomographic measurement within an 8 min scan with density resolution of 2.4 mg/cm3. A maximum volume size of 13 × 13 × 6 mm3 was obtained with a single tomographic measurement with a voxel size of 6.5 μm. The scanning procedure using the triangle wave was applied to four-dimensional measurements in which highly sensitive three-dimensional x-ray imaging and a time-resolved dynamic measurement of biological samples were combined. A fresh tendon in the tail of a rat was measured under a uniaxial stretching and releasing condition. To maintain the freshness of the sample during four-dimensional phase contrast tomography, the temperature of the bathing liquid of the sample was kept below 10° using a simple cooling system. The time-resolved deformation of the tendon and each fascicle was measured with a temporal resolution of 5.7 Hz. Evaluations of cross-sectional area size, length of the axis, and mass density in the fascicle during a stretching process provided a basis for quantitative analysis of the deformation of tendon fascicle.

  15. 4D x-ray phase contrast tomography for repeatable motion of biological samples.

    PubMed

    Hoshino, Masato; Uesugi, Kentaro; Yagi, Naoto

    2016-09-01

    X-ray phase contrast tomography based on a grating interferometer was applied to fast and dynamic measurements of biological samples. To achieve this, the scanning procedure in the tomographic scan was improved. A triangle-shaped voltage signal from a waveform generator to a Piezo stage was used for the fast phase stepping in the grating interferometer. In addition, an optical fiber coupled x-ray scientific CMOS camera was used to achieve fast and highly efficient image acquisitions. These optimizations made it possible to perform an x-ray phase contrast tomographic measurement within an 8 min scan with density resolution of 2.4 mg/cm 3 . A maximum volume size of 13 × 13 × 6 mm 3 was obtained with a single tomographic measurement with a voxel size of 6.5 μm. The scanning procedure using the triangle wave was applied to four-dimensional measurements in which highly sensitive three-dimensional x-ray imaging and a time-resolved dynamic measurement of biological samples were combined. A fresh tendon in the tail of a rat was measured under a uniaxial stretching and releasing condition. To maintain the freshness of the sample during four-dimensional phase contrast tomography, the temperature of the bathing liquid of the sample was kept below 10° using a simple cooling system. The time-resolved deformation of the tendon and each fascicle was measured with a temporal resolution of 5.7 Hz. Evaluations of cross-sectional area size, length of the axis, and mass density in the fascicle during a stretching process provided a basis for quantitative analysis of the deformation of tendon fascicle.

  16. Low-Dose-Rate Computed Tomography System Utilizing 25 mm/s-Scan Silicon X-ray Diode and Its Application to Iodine K-Edge Imaging Using Filtered Bremsstrahlung Photons

    NASA Astrophysics Data System (ADS)

    Matsushita, Ryo; Sato, Eiichi; Yanbe, Yutaka; Chiba, Hiraku; Maeda, Tomoko; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Watanabe, Manabu; Kusachi, Shinya; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun

    2013-03-01

    A low-dose-rate X-ray computed tomography (CT) system is useful for reducing absorbed dose for patients. The CT system with a tube current of sub-mA was developed using a silicon X-ray diode (Si-XD). The Si-XD is a high-sensitivity Si photodiode (PD) selected for detecting X-ray photons, and the X-ray sensitivity of the Si-XD was twice as high as that of Si-PD cerium-doped yttrium aluminum perovskite [YAP(Ce)]. X-ray photons are directly detected using the Si-XD without a scintillator, and the photocurrent from the diode is amplified using current-voltage and voltage-voltage amplifiers. The output voltage is converted into logical pulses using a voltage-frequency converter with a maximum frequency of 500 kHz, and the frequency is proportional to the voltage. The pulses from the converter are sent to the differentiator with a time constant of 500 ns to generate short positive pulses for counting, and the pulses are counted using a counter card. Tomography is accomplished by repeated linear scans and rotations of an object, and projection curves of the object are obtained by the linear scan. The exposure time for obtaining a tomogram was 5 min at a scan step of 0.5 mm and a rotation step of 3.0°. The tube current and voltage were 0.55 mA and 60 kV, respectively, and iodine K-edge CT was carried out using filtered bremsstrahlung X-ray spectra with a peak energy of 38 keV.

  17. Kinetics of leukocyte sequestration in the lungs of acutely septic primates: A study using sup 111 In-labeled autologous leukocytes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hangen, D.H.; Segall, G.M.; Harney, E.W.

    1990-03-01

    To further clarify the role of leukocytes in the pathogenesis of ARDS, we studied the localization and kinetics of leukocyte migration using 111In-labeled autologous white cell scans ({sup 111}In wbc scans) in four primates made acutely septic with infusions of Escherichia coli. Whole body images were obtained with a gamma camera and were acquired on computer every 15 min beginning immediately after the E. coli infusion. Simultaneous measurements of C5a and peripheral blood leukocyte count were also obtained. Within 5 min of initiating sepsis, three major events occurred: complement activation as measured by the production of C5a, a profound fallmore » in peripheral leukocyte count, and a significant increase in the sequestration of leukocytes in the lungs. The pulmonary sequestration reached a peak at 15 min with a mean of 152% of baseline activity. This sequestration consisted of a population that was predominantly neutrophils. Damage to the pulmonary capillary endothelium was demonstrated by an increase in extravascular lung water. The results support a role for neutrophils and complement as mediators in the pathogenesis of ARDS.« less

  18. Kidney stone erosion by micro scale hydrodynamic cavitation and consequent kidney stone treatment.

    PubMed

    Perk, Osman Yavuz; Şeşen, Muhsincan; Gozuacik, Devrim; Koşar, Ali

    2012-09-01

    The objective of this study is to reveal the potential of micro scale hydrodynamic bubbly cavitation for the use of kidney stone treatment. Hydrodynamically generated cavitating bubbles were targeted to the surfaces of 18 kidney stone samples made of calcium oxalate, and their destructive effects were exploited in order to remove kidney stones in in vitro experiments. Phosphate buffered saline (PBS) solution was used as the working fluid under bubbly cavitating conditions in a 0.75 cm long micro probe of 147 μm inner diameter at 9790 kPa pressure. The surface of calcium oxalate type kidney stones were exposed to bubbly cavitation at room temperature for 5 to 30 min. The eroded kidney stones were visually analyzed with a high speed CCD camera and using SEM (scanning electron microscopy) techniques. The experiments showed that at a cavitation number of 0.017, hydrodynamic bubbly cavitation device could successfully erode stones with an erosion rate of 0.31 mg/min. It was also observed that the targeted application of the erosion with micro scale hydrodynamic cavitation may even cause the fracture of the kidney stones within a short time of 30 min. The proposed treatment method has proven to be an efficient instrument for destroying kidney stones.

  19. Effect of ultrasound treatment on the water state in kiwifruit during osmotic dehydration.

    PubMed

    Nowacka, M; Tylewicz, U; Laghi, L; Dalla Rosa, M; Witrowa-Rajchert, D

    2014-02-01

    The present work investigates how ultrasound pretreatment modulates the effects of osmotic dehydration (OD) on the water state and microstructure of kiwifruit. Kiwifruit slices (10mm thick) were subjected to ultrasonic waves in a water bath at a frequency of 35 kHz for 10, 20 and 30 min. OD process was then carried out by immersing the samples in 61.5% sucrose solution equilibrated at 25°C for a contact period of 0, 10, 20, 30, 60 and 120 min. The partition of water into the cellular tissue structures (vacuole, cytoplasm, extracellular spaces and cell wall) was investigated by Time Domain Nuclear Magnetic Resonance (TD-NMR). In parallel, the microstructure of kiwifruits slices was examined using a Scanning Electron Microscope. The results showed that US pretreatment performed for more than 10 min had a positive effect on the mass exchange caused by osmotic dehydration. A creation of microchannels and an increase of the average cross-section area of cells were observed when the samples were pretreated with US before OD. TD-NMR showed a slight redistribution of water through the substructures of the cells, as a function of the length of the US pretreatment applied. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  20. Fast hydrogen sorption from MgH2-VO2(B) composite materials

    NASA Astrophysics Data System (ADS)

    Milošević, Sanja; Kurko, Sandra; Pasquini, Luca; Matović, Ljiljana; Vujasin, Radojka; Novaković, Nikola; Novaković, Jasmina Grbović

    2016-03-01

    The hydrogen sorption kinetics of MgH2‒VO2(B) composites synthesised by mechanical milling have been studied. The microstructural properties of composites were characterized by means of X-ray diffraction (XRD), Raman spectroscopy, Scanning electron microscopy (SEM), Particle size analysis (PSD), while sorption behaviour was followed by differential scanning calorimetry (DSC) and Sievert measurements. Results have shown that although desorption temperature reduction is moderate; there is a substantial improvement in hydrogen sorption kinetics. The complete desorption of pure MgH2 at elevated temperature takes place in more than 30 min while the composite fully desorbs in less than 2 min even at lower temperatures. It has been shown that the metastable γ-MgH2 phase and the point defects have a decisive role in desorption process only in the first sorption cycle, while the second and the subsequent sorption cycles are affected by microstructural and morphological characteristics of the composite.

  1. Sex difference in Double Iron ultra-triathlon performance

    PubMed Central

    2013-01-01

    Background The present study examined the sex difference in swimming (7.8 km), cycling (360 km), running (84 km), and overall race times for Double Iron ultra-triathletes. Methods Sex differences in split times and overall race times of 1,591 men and 155 women finishing a Double Iron ultra-triathlon between 1985 and 2012 were analyzed. Results The annual number of finishes increased linearly for women and exponentially for men. Men achieved race times of 1,716 ± 243 min compared to 1,834 ± 261 min for women and were 118 ± 18 min (6.9%) faster (p < 0.01). Men finished swimming within 156 ± 63 min compared to women with 163 ± 31 min and were 8 ± 32 min (5.1 ± 5.0%) faster (p < 0.01). For cycling, men (852 ± 196 min) were 71 ± 70 min (8.3 ± 3.5%) faster than women (923 ± 126 min) (p < 0.01). Men completed the run split within 710 ± 145 min compared to 739 ± 150 min for women and were 30 ± 5 min (4.2 ± 3.4%) faster (p = 0.03). The annual three fastest men improved race time from 1,650 ± 114 min in 1985 to 1,339 ± 33 min in 2012 (p < 0.01). Overall race time for women remained unchanged at 1,593 ± 173 min with an unchanged sex difference of 27.1 ± 8.6%. In swimming, the split times for the annual three fastest women (148 ± 14 min) and men (127 ± 20 min) remained unchanged with an unchanged sex difference of 26.8 ± 13.5%. In cycling, the annual three fastest men improved the split time from 826 ± 60 min to 666 ± 18 min (p = 0.02). For women, the split time in cycling remained unchanged at 844 ± 54 min with an unchanged sex difference of 25.2 ± 7.3%. In running, the annual fastest three men improved split times from 649 ± 77 min to 532 ± 16 min (p < 0.01). For women, however, the split times remained unchanged at 657 ± 70 min with a stable sex difference of 32.4 ± 12.5%. Conclusions To summarize, the present findings showed that men were faster than women in Double Iron ultra-triathlon, men improved overall race times, cycling and running split times, and the sex difference remained unchanged across years for overall race time and split times. The sex differences for overall race times and split times were higher than reported for Ironman triathlon. PMID:23849631

  2. Effects of Cue Reliability on Target Detection and Visual Scanning

    DTIC Science & Technology

    2010-12-01

    instruction on how to rate his workload experience using the NASA-TLX. The participant then completed one 3-min practice ride in each of the four...participant practiced completing the NASA-TLX to rate his workload experience. 3.4.2 Test Procedures After a 5-min rest break, the test period...RDRL HRM A J MARTIN MYER CENTER BLDG 2700 RM 2D311 FORT MONMOUTH NJ 07703-5601 1 ARMY RSCH LABORATORY – HRED RDRL HRM C A DAVISON

  3. HAZ and Structural Defects Control in Key-Hole Welding of Titanium Using a Reptitively-Pulsed Nd: Yag Laser

    NASA Astrophysics Data System (ADS)

    Hamudi, Walid K.

    1996-12-01

    HAZ, porosity and cracks were investigated when welding 0.9 mm thick titanium sheets using a 10 J pulsed Nd: Yag laser. The effects of welding speed, joints fit-up, shielding gas, and laser parameters are presented. For optimum welding quality, 0.25 m/min scanning speed, 10 ℓ/min gas flow rate and 72 Watt average power were used. Welds of narrow heat affected zone (HAZ) with small level of porosity were obtained.

  4. Laparoscopic microwave thermosphere ablation of malignant liver tumors: an initial clinical evaluation.

    PubMed

    Berber, Eren

    2016-02-01

    Microwave ablation (MWA) has been recently recognized as a technology to overcome the limitations of radiofrequency ablation. The aim of the current study was to evaluate the safety and efficacy of a new 2.45-GHz thermosphere MWA system in the treatment of malignant liver tumors. This was a prospective IRB-approved study of 18 patients with malignant liver tumors treated with MWA within a 3-month time period. Tumor sizes and response to MWA were obtained from triphasic liver CT scans done before and after MWA. The ablation zones were assessed for complete tumor response and spherical geometry. There were a total of 18 patients with an average of three tumors measuring 1.4 cm (range 0.2-4). Ablations were performed laparoscopically in all, but three patients who underwent combined liver resection. A single ablation was created in 72% and overlapping ablations in 28% of lesions. Total ablation time per patient was 15.6 ± 1.9 min. There was no morbidity or mortality. At 2-week CT scans, there was 100% tumor destruction, with no residual lesions. Roundness indices A, B and transverse were 1.1, 0.9 and 0.9, respectively, confirming the spherical nature of ablation zones. To the best of our knowledge, this is the first report of a new thermosphere MWA technology in the laparoscopic treatment of malignant liver tumors. The results demonstrate the safety of the technology, with satisfactory spherical ablation zones seen on post-procedural CT scans.

  5. High-sensitive computed tomography system using a silicon-PIN x-ray diode

    NASA Astrophysics Data System (ADS)

    Sato, Eiichi; Sato, Yuich; Abudurexiti, Abulajiang; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Watanabe, Manabu; Kusachi, Shinya; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun

    2012-10-01

    A low-dose-rate X-ray computed tomography (CT) system is useful for reducing absorbed dose for patients. The CT system with a tube current of 1.91 mA was developed using a silicon-PIN X-ray diode (Si-PIN-XD). The Si-PIN-XD is a selected high-sensitive Si-PIN photodiode (PD) for detecting X-ray photons. X-ray photons are detected directly using the Si-PIN-XD without a scintillator, and the photocurrent from the diode is amplified using current-voltage and voltage-voltage amplifiers. The output voltage is converted into logical pulses using a voltage-frequency converter with maximum frequency of 500 kHz, and the frequency is proportional to the voltage. The pulses from the converter are sent to differentiator with a time constant of 1 μs to generate short positive pulses for counting, and the pulses are counted using a counter card. Tomography is accomplished by repeated linear scans and rotations of an object, and projection curves of the object are obtained by the linear scan. The exposure time for obtaining a tomogram was 5 min at a scan step of 0.5 mm and a rotation step of 3.0°. The tube current and voltage were 1.91 mA and 100 kV, respectively, and gadolinium K-edge CT was carried out using filtered X-ray spectra with a peak energy of 52 keV.

  6. An automatic alignment system for measuring optical path of transmissometer based on light beam scanning

    NASA Astrophysics Data System (ADS)

    Zhou, Shudao; Ma, Zhongliang; Wang, Min; Peng, Shuling

    2018-05-01

    This paper proposes a novel alignment system based on the measurement of optical path using a light beam scanning mode in a transmissometer. The system controls both the probe beam and the receiving field of view while scanning in two vertical directions. The system then calculates the azimuth angle of the transmitter and the receiver to determine the precise alignment of the optical path. Experiments show that this method can determine the alignment angles in less than 10 min with errors smaller than 66 μrad in the azimuth. This system also features high collimation precision, process automation and simple installation.

  7. 68Ga-PSMA PET/CT in patients with recurrent prostate cancer after radical treatment: prospective results in 314 patients.

    PubMed

    Caroli, Paola; Sandler, Israel; Matteucci, Federica; De Giorgi, Ugo; Uccelli, Licia; Celli, Monica; Foca, Flavia; Barone, Domenico; Romeo, Antonino; Sarnelli, Anna; Paganelli, Giovanni

    2018-06-19

    We studied the usefulness of 68 Ga-prostate-specific membrane antigen (PSMA) PET/CT for detecting relapse in a prospective series of patients with biochemical recurrence (BCR) of prostate cancer (PCa) after radical treatment. Patients with BCR of PCa after radical surgery and/or radiotherapy with or without androgen-deprivation therapy were included in the study. 68 Ga-PSMA PET/CT scans performed from the top of the head to the mid-thigh 60 min after intravenous injection of 150 ± 50 MBq of 68 Ga-PSMA were interpreted by two nuclear medicine physicians. The results were correlated with prostate-specific antigen (PSA) levels at the time of the scan (PSApet), PSA doubling time, Gleason score, tumour stage, postsurgery tumour residue, time from primary therapy to BCR, and patient age. When available, 68 Ga-PSMA PET/CT scans were compared with negative 18 F-choline PET/CT scans routinely performed up to 1 month previously. From November 2015 to October 2017, 314 PCa patients with BCR were evaluated. Their median age was 70 years (range 44-92 years) and their median PSApet was 0.83 ng/ml (range 0.003-80.0 ng/ml). 68 Ga-PSMA PET/CT was positive (one or more suspected PCa lesions detected) in 197 patients (62.7%). Lesions limited to the pelvis, i.e. the prostate/prostate bed and/or pelvic lymph nodes (LNs), were detected in 117 patients (59.4%). At least one distant lesion (LNs, bone, other organs, separately or combined with local lesions) was detected in 80 patients (40.6%). PSApet was higher in PET-positive than in PET-negative patients (P < 0.0001). Of 88 patients negative on choline PET/CT scans, 59 (67%) were positive on 68 Ga-PSMA PET/CT. We confirmed the value of 68 Ga-PSMA PET/CT in restaging PCa patients with BCR, highlighting its superior performance and safety compared with choline PET/CT. Higher PSApet was associated with a higher relapse detection rate.

  8. 18F-Alfatide II and 18F-FDG Dual Tracer Dynamic PET for Parametric, Early Prediction of Tumor Response to Therapy

    PubMed Central

    Guo, Jinxia; Guo, Ning; Lang, Lixin; Kiesewetter, Dale O.; Xie, Qingguo; Li, Quanzheng; Eden, Henry S.; Niu, Gang; Chen, Xiaoyuan

    2014-01-01

    A single dynamic PET acquisition using multiple tracers administered closely in time could provide valuable complementary information about a tumor’s status under quasi-constant conditions. This study aims to investigate the utility of dual-tracer dynamic PET imaging with 18F-Alfatide II (18F-AlF-NOTA-E[PEG4-c(RGDfk)]2) and 18F-FDG for parametric monitoring of tumor responses to therapy. Methods We administered doxorubicin to one group of athymic nude mice with U87MG tumors and Abraxane to another group of mice with MDA-MB-435 tumors. To monitor therapeutic responses, we performed dual-tracer dynamic imaging, in sessions that lasted 90 min, starting by injecting the mice via tail vein catheters with 18F-Alfatide II, followed 40 minutes later by 18F-FDG. To achieve signal separation of the two tracers, we fit a three-compartment reversible model to the time activity curve (TAC) of 18F-Alfatide II for the 40 min prior to 18F-FDG injection, and then extrapolated to 90 min. The 18F-FDG tumor TAC was isolated from the 90 min dual tracer tumor TAC by subtracting the fitted 18F-Alfatide II tumor TAC. With separated tumor TACs, the 18F-Alfatide II binding potential (Bp=k3/k4) and volume of distribution (VD), and 18F-FDG influx rate ((K1×k3)/(k2 + k3)) based on the Patlak method were calculated to validate the signal recovery in a comparison with 60-min single tracer imaging and to monitor therapeutic response. Results The transport and binding rate parameters K1-k3 of 18F-Alfatide II, calculated from the first 40 min of dual tracer dynamic scan, as well as Bp and VD, correlated well with the parameters from the 60 min single tracer scan (R2 > 0.95). Compared with the results of single tracer PET imaging, FDG tumor uptake and influx were recovered well from dual tracer imaging. Upon doxorubicin treatment, while no significant changes in static tracer uptake values of 18F-Alfatide II or 18F-FDG were observed, both 18F-Alfatide II Bp and 18F-FDG influx from kinetic analysis in tumors showed significant decreases. For Abraxane therapy of MDA-MB-435 tumors, significant decrease was only observed with 18F-Alfatide II Bp value from kinetic analysis but not 18F-FDG influx. Conclusion The parameters fitted with compartmental modeling from the dual tracer dynamic imaging are consistent with those from single tracer imaging, substantiating the feasibility of this methodology. Even though no significant differences in tumor size were found until 5 days after doxorubicin treatment started, at day 3 there were already substantial differences in 18F-Alfatide II Bp and 18F-FDG influx rate. Dual tracer imaging can measure 18F-Alfatide II Bp value and 18F-FDG influx simultaneously to evaluate tumor angiogenesis and metabolism. Such changes are known to precede anatomical changes, and thus parametric imaging may offer the promise of early prediction of therapy response. PMID:24232871

  9. Sterilization effects of atmospheric cold plasma brush

    NASA Astrophysics Data System (ADS)

    Yu, Q. S.; Huang, C.; Hsieh, F.-H.; Huff, H.; Duan, Yixiang

    2006-01-01

    This study investigated the sterilization effects of a brush-shaped plasma created at one atmospheric pressure. A population of 1.0×104-1.0×105 Escherichia coli or Micrococcus luteus bacteria was seeded in filter paper media and then subjected to Ar and/or Ar +O2 plasmas. A complete kill of the Micrococcus luteus required about 3 min argon plasma exposures. With oxygen addition into the argon plasma gas streams, a complete kill of the bacteria needed only less than 1 min plasma exposure for Micrococcus luteus and about 2 min exposure for Escherichia coli. The plasma treatment effects on the different bacteria cell structures were examined using scanning electron microscopy.

  10. Whole body sodium MRI at 3T using an asymmetric birdcage resonator and short echo time sequence: first images of a male volunteer.

    PubMed

    Wetterling, Friedrich; Corteville, Dominique M; Kalayciyan, Raffi; Rennings, Andreas; Konstandin, Simon; Nagel, Armin M; Stark, Helmut; Schad, Lothar R

    2012-07-21

    Sodium magnetic resonance imaging (²³Na MRI) is a non-invasive technique which allows spatial resolution of the tissue sodium concentration (TSC) in the human body. TSC measurements could potentially serve to monitor early treatment success of chemotherapy on patients who suffer from whole body metastases. Yet, the acquisition of whole body sodium (²³Na) images has been hampered so far by the lack of large resonators and the extremely low signal-to-noise ratio (SNR) achieved with existing resonator systems. In this study, a ²³Na resonator was constructed for whole body ²³Na MRI at 3T comprising of a 16-leg, asymmetrical birdcage structure with 34 cm height, 47.5 cm width and 50 cm length. The resonator was driven in quadrature mode and could be used either as a transceiver resonator or, since active decoupling was included, as a transmit-only resonator in conjunction with a receive-only (RO) surface resonator. The relative B₁-field profile was simulated and measured on phantoms, and 3D whole body ²³Na MRI data of a healthy male volunteer were acquired in five segments with a nominal isotropic resolution of (6 × 6 × 6) mm³ and a 10 min acquisition time per scan. The measured SNR values in the ²³Na-MR images varied from 9 ± 2 in calf muscle, 15 ± 2 in brain tissue, 23 ± 2 in the prostate and up to 42 ± 5 in the vertebral discs. Arms, legs, knees and hands could also be resolved with applied resonator and short time-to-echo (TE) (0.5 ms) radial sequence. Up to fivefold SNR improvement was achieved through combining the birdcage with local RO surface coil. In conclusion, ²³Na MRI of the entire human body provides sub-cm spatial resolution, which allows resolution of all major human body parts with a scan time of less than 60 min.

  11. Multi-residue determination of seventeen sulfonamides and five tetracyclines in fish tissue using a multi-stage LC-ESI-MS/MS approach based on advanced mass spectrometric techniques.

    PubMed

    Dasenaki, Marilena E; Thomaidis, Nikolaos S

    2010-07-05

    A strategy was newly developed to rapidly screen seventeen sulfonamides and five tetracyclines in a single run from fish tissues using ultra-high performance liquid chromatography (UHPLC) coupled with comprehensive mass spectrometric approaches, including precursor-ion scan and data dependent scan. The product ions for precursor-ion scanning were selected by studying the MS/MS fragmentation of the analytes. All sulfonamides share the same diagnostic product ion at m/z 156 in positive MS/MS scan, while for tetracycline antibiotics the diagnostic product ion was proved to be at m/z 153.8. Further characterization of each compound was performed using a data dependent scan. Separation was performed on a Zorbax Eclipse Plus C18 column with a gradient elution using acetonitrile - 0.1% formic acid mobile phase at a flow rate of 0.1 mL min(-1). This approach has proven to be a powerful, highly selective, and sensitive tool for rapid screening and detection of non-targeted components in fish tissue and requires a minimum sample preparation such as one generic extraction step with MeOH:ACN 50:50 (v/v) acidified with 0.05% formic acid. The method has also been applied successfully to porcine and poultry meat. The validation of such a screening method was performed for the first time according to Commission Decision 2002/657/EC and satisfactory method performance characteristics were achieved. Copyright 2010 Elsevier B.V. All rights reserved.

  12. Ipsilateral renal function preservation after robot-assisted partial nephrectomy (RAPN): an objective analysis using mercapto-acetyltriglycine (MAG3) renal scan data and volumetric assessment.

    PubMed

    Zargar, Homayoun; Akca, Oktay; Autorino, Riccardo; Brandao, Luis Felipe; Laydner, Humberto; Krishnan, Jayram; Samarasekera, Dinesh; Stein, Robert J; Kaouk, Jihad H

    2015-05-01

    To objectively assess ipsilateral renal function (IRF) preservation and factors influencing it after robot-assisted partial nephrectomy (RAPN). Our database was queried to identify patients who had undergone RAPN from 2007 to 2013 and had complete pre- and postoperative mercapto-acetyltriglycine (MAG3) renal scan assessment. The estimated glomerular filtration rate (eGFR) for the operated kidney was calculated by multiplying the percentage of contribution from the renal scan by the total eGFR. IRF preservation was defined as a ratio of the postoperative eGFR for the operated kidney to the preoperative eGFR for the operated kidney. The percentage of total eGFR preservation was calculated in the same manner (postoperative eGFR/preoperative eGFR × 100). The amount of healthy rim of renal parenchyma removed was assessed by deducting the volume of tumour from the volume of the PN specimen assessed on pathology. Multivariable linear regression was used for analysis. In all, 99 patients were included in the analysis. The overall median (interquartile range) total eGFR preservation and IRF preservation for the operated kidney was 83.83 (75.2-94.1)% and 72 (60.3-81)%, respectively (P < 0.01). On multivariable analysis, volume of healthy rim of renal parenchyma removed, warm ischaemia time (WIT) > 30 min, body mass index (BMI) and operated kidney preoperative eGFR were predictive of IRF preservation. Using total eGFR tends to overestimate the degree of renal function preservation after RAPN. This is particularly relevant when studying factors affecting functional outcomes after nephron-sparing surgery. IRF may be a more precise assessment method in this setting. Operated kidney baseline renal function, BMI, WIT >30 min, and amount of resected healthy renal parenchyma represent the factors with a significant impact on the IRF preservation. RAPN provides significant preservation of renal function as shown by objective assessment criteria. © 2014 The Authors. BJU International © 2014 BJU International.

  13. Ionic liquid-based microwave-assisted extraction of essential oil and biphenyl cyclooctene lignans from Schisandra chinensis Baill fruits.

    PubMed

    Ma, Chun-hui; Liu, Ting-ting; Yang, Lei; Zu, Yuan-gang; Chen, Xiaoqiang; Zhang, Lin; Zhang, Ying; Zhao, Chunjian

    2011-12-02

    Ionic liquid-based microwave-assisted extraction (ILMAE) has been successfully applied in extracting essential oil and four kinds of biphenyl cyclooctene lignans from Schisandra chinensis Baill. 0.25 M 1-lauryl-3-methylimidazolium bromide ionic liquid is selected as solvent. The optimum parameters of dealing with 25.0 g sample are 385 W irradiation power, 40 min microwave extraction time and 1:12 solid-liquid ratio. The yields of essential oil and lignans are 12.12±0.37 ml/kg and 250.2±38.2 mg/kg under the optimum conditions. The composition of the essential oil extracted by hydro-distillation, steam-distillation and ILMAE is analyzed by GC-MS. With ILMAE method, the energy consumption time has not only been shortened to 40 min (hydro-distillation 3.0 h for extracting essential oil and reflux extraction 4.0 h for extracting lignans, respectively), but also the extraction efficiency has been improved (extraction of lignans and distillation of essential oil at the same time) and reduces the environmental pollution. S. chinensis materials treated by different methods are observed by scanning electronic microscopy. Micrographs provide more evidence to prove that ILMAE is a better and faster method. The experimental results also indicate that ILMAE is a simple and efficient technique for sample preparation. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Influence of Applied Voltage and Film-Formation Time on Microstructure and Corrosion Resistance of Coatings Formed on Mg-Zn-Zr-Ca Bio-magnesium Alloy

    NASA Astrophysics Data System (ADS)

    Yandong, Yu; Shuzhen, Kuang; Jie, Li

    2015-09-01

    The influence of applied voltage and film-formation time on the microstructure and corrosion resistance of coatings formed on a Mg-Zn-Zr-Ca novel bio-magnesium alloy has been investigated by micro-arc oxidation (MAO) treatment. Phase composition and microstructure of as-coated samples were analyzed by the x-ray diffraction, energy dispersive x-ray spectroscopy and scanning electron microscopy. And the porosity and average of micro-pore aperture of the surface on ceramic coatings were analyzed by general image software. Corrosion microstructure of as-coated samples was caught by a microscope digital camera. The long-term corrosion resistance of as-coated samples was tested in simulated body fluid for 30 days. The results showed that the milky white smooth ceramic coating formed on the Mg-Zn-Zr-Ca novel bio-magnesium alloy was a compound of MgO, Mg2SiO4 and MgSiO3, and its corrosion resistance was significantly improved compared with that of the magnesium substrate. In addition, when the MAO applied voltage were 450 V and 500 V and film-formation time were 9 min and 11 min, the surface micro-morphology and the corrosion resistance of as-coated samples were relatively improved. The results provided a theoretical foundation for the application of the Mg-Zn-Zr-Ca novel bio-magnesium alloy in biomedicine.

  15. Application of high-performance liquid chromatography to the determination of glyoxylate synthesis in chick embryo liver.

    PubMed

    Qureshi, A A; Elson, C E; Lebeck, L A

    1982-11-19

    The isolation and identification of three major alpha-keto end products (glyoxylate, pyruvate, alpha-ketoglutarate) of the isocitrate lyase reaction in 18-day chick embryo liver have been described. This was accomplished by the separation of these alpha-keto acids as their 2,4-dinitrophenylhydrazones (DNPHs) by high-performance liquid chromatography (HPLC). The DNPHs of alpha-keto acids were eluted with an isocratic solvent system of methanol-water-acetic acid (60:38.5:1.5) containing 5 mM tetrabutylammonium phosphate from a reversed-phase ultrasphere C18 (IP) and from a radial compression C18 column. The separation can be completed on the radial compression column within 15-20 min as compared to 30-40 min with a conventional reversed-phase column. Retention times and peak areas were integrated for both the assay samples and reference compounds. A relative measure of alpha-keto acid in the peak was calculated by comparison with the standard. The identification of each peak was done on the basis of retention time matching, co-chromatography with authentic compounds, and stopped flow UV-VIS scanning between 240 and 440 nm. Glyoxylate represented 5% of the total product of the isocitrate lyase reaction. Day 18 parallels the peak period of embryonic hepatic glycogenesis which occurs at a time when the original egg glucose reserve has been depleted.

  16. Biodistribution of 99mTc-MAA on SPECT/CT performed for 90Y radioembolization therapy planning: a pictorial review.

    PubMed

    Bailey, J J; Dewaraja, Y; Hubers, D; Srinivasa, R N; Frey, K A

    2017-10-01

    To evaluate the frequency of 99mTc-MAA uptake in extrahepatic organs during 90Y radioembolization therapy planning. This retrospective case series of 70 subjects who underwent 99mTc-MAA hepatic artery perfusion studies between January 2014 and July 2016 for 90Y radioembolization therapy planning at our institution involved direct image review for all subjects, with endpoints recorded: lung shunt fraction, extrahepatic radiotracer uptake, time from MAA injection to imaging. Combined planar and SPECT/CT imaging findings in the 70 subjects demonstrated lung shunt fraction measurements of less than 10% in 53 (76%) subjects and greater than 10% in 17 (24%) subjects. All patients demonstrated renal cortical uptake, 23 (33%) demonstrated salivary gland uptake, 23 (33%) demonstrated thyroid uptake, and 32 (46%) demonstrated gastric mucosal uptake, with significant overlap between these groups. The range of elapsed times between MAA injection and initial imaging was 41-138 min, with a mean of 92 min. There was no correlation between time to imaging and the presence of extrahepatic radiotracer uptake at any site. During hepatic artery perfusion scanning for 90Y radioembolization therapy planning, extrahepatic uptake is common, particularly in the kidney, salivary gland, thyroid and gastric mucosa, and is hypothesized to result from breakdown of 99mTc-MAA over time. Given the breakdown to smaller aggregates and ultimately pertechnetate, this should not be a contraindication to actual Y-90 microsphere therapy. Although we found no correlation between time to imaging and extrahepatic uptake, most of our injection to imaging times were relatively short.

  17. [Determination of fatty acids in natural cream and artificial cream by comprehensive two-dimensional gas chromatography-mass spectrometry].

    PubMed

    Zhou, Ruize; Zhou, Ya; Mao, Ting; Jiang, Jie

    2018-01-08

    A method for the determination of 37 fatty acids in natural cream and artificial cream was developed by comprehensive two-dimensional gas chromatography-mass spectrometry (GC×GC-MS). The samples were extracted with toluene and acetyl chloride-methanol (1:9,v/v) solution was added to the extract for fat esterification. Finally, the fatty acids were analyzed by GC×GC-MS. The GC conditions were as follows:a DB-5 column (30 m×0.25 mm×0.25 μm) was set as the 1st dimensional column and a BPX-50 column (2.5 m×0.1 mm×0.25 μm) was the 2nd dimensional column. The primary oven temperature was programmed from 50℃ (held for 2 min) to 180℃ at a rate of 20℃/min, followed by an increase to 250℃ at 2.5℃/min, then raised up to 300℃ (held for 5 min) at 3℃/min. The ion source temperature was 200℃ with auxiliary temperature of 300℃ in scan mode. All fatty acids were separated effectively and determined accurately while the modulation period was 5s and the scan range of MS was m/z 40-385. This procedure was applied to analyze the fatty acids in commercial natural cream and artificial cream from Chinese markets, among which we found the characteristic components in different kinds of samples. Compared with gas chromatography-flame ionization detector (GC-FID), GC×GC-MS method was more sensitive and more components of fatty acids were detected. Conclusively, this work suggests a new technical approach in analyzing fatty acids in natural cream and artificial cream, which is meaningful to ensure the quality identification and safety of natural cream.

  18. Novel Electrochemical Process for Treatment of Perchlorate in Waste Water

    DTIC Science & Technology

    2011-03-06

    Prepared in Different Processes: (b) in 0.1 M Pyrrole Solution with 0.1 M NaCl at 0.8 V for 20 min; (c) at 0.5 V for 400 s in 0.1 M ClO4- Solution and...polypyrrole Py pyrrole SEM scanning electron microscopy SON statement of need XPS X-ray photoelectron spectroscopy v Acknowledgments This work is...shows the scanning electron microscopy (SEM) images of carbon fiber paper and a CNT array grown on carbon fiber paper. Pyrrole (Py) deposition

  19. Decompression Sickness After Air Break in Prebreathe Described with a Survival Model

    NASA Technical Reports Server (NTRS)

    Conkin, J.; Pilmanis, A. A.

    2010-01-01

    Data from Brooks City-Base show the decompression sickness (DCS) and venous gas emboli (VGE) consequences of air breaks in a resting 100% O2 prebreathe (PB) prior to a hypobaric exposure. METHODS: DCS and VGE survival times from 95 controls for a 60 min PB prior to 2-hr or 4-hr exposures to 4.37 psia are statistically compared to 3 break in PB conditions: a 10 min (n=40), 20 min (n=40), or 60 min break (n=32) 30 min into the PB followed by 30 min of PB. Ascent rate was 1,524 meters / min and all exposures included light exercise and 4 min of VGE monitoring of heart chambers at 16 min intervals. DCS survival time for combined control and air breaks were described with an accelerated log logistic model where exponential N2 washin during air break was described with a 10 min half-time and washout during PB with a 60 min half-time. RESULTS: There was no difference in VGE or DCS survival times among 3 different air breaks, or when air breaks were compared to control VGE times. However, 10, 20, and 60 min air breaks had significantly earlier survival times compared to control DCS times, certainly early in the exposures. CONCLUSION: Air breaks of 10, 20, and 60 min after 30 min of a 60 min PB reduced DCS survival time. The survival model combined discrete comparisons into a global description mechanistically linked to asymmetrical N2 washin and washout kinetics based on inspired pN2. Our unvalidated regression is used to compute additional PB time needed to compensate for an air break in PB within the range of tested conditions.

  20. Effects of Frequency Drift on the Quantification of Gamma-Aminobutyric Acid Using MEGA-PRESS

    NASA Astrophysics Data System (ADS)

    Tsai, Shang-Yueh; Fang, Chun-Hao; Wu, Thai-Yu; Lin, Yi-Ru

    2016-04-01

    The MEGA-PRESS method is the most common method used to measure γ-aminobutyric acid (GABA) in the brain at 3T. It has been shown that the underestimation of the GABA signal due to B0 drift up to 1.22 Hz/min can be reduced by post-frequency alignment. In this study, we show that the underestimation of GABA can still occur even with post frequency alignment when the B0 drift is up to 3.93 Hz/min. The underestimation can be reduced by applying a frequency shift threshold. A total of 23 subjects were scanned twice to assess the short-term reproducibility, and 14 of them were scanned again after 2-8 weeks to evaluate the long-term reproducibility. A linear regression analysis of the quantified GABA versus the frequency shift showed a negative correlation (P < 0.01). Underestimation of the GABA signal was found. When a frequency shift threshold of 0.125 ppm (15.5 Hz or 1.79 Hz/min) was applied, the linear regression showed no statistically significant difference (P > 0.05). Therefore, a frequency shift threshold at 0.125 ppm (15.5 Hz) can be used to reduce underestimation during GABA quantification. For data with a B0 drift up to 3.93 Hz/min, the coefficients of variance of short-term and long-term reproducibility for the GABA quantification were less than 10% when the frequency threshold was applied.

  1. Cocaine and methamphetamine induce opposing changes in BOLD signal response in rats.

    PubMed

    Taheri, Saeid; Xun, Zhu; See, Ronald E; Joseph, Jane E; Reichel, Carmela M

    2016-07-01

    Neuroimaging studies in psychostimulant addicts have reported functional neural activity changes in brain regions involved in relapse. However, the difference between the effects of the psychostimulants methamphetamine and cocaine on neuronal activity in a similar setting not been clarified. Since studies in humans are limited by the inability to study the initial impact of psychostimulant drugs, we addressed this issue in a rat model. Here, we report methamphetamine and cocaine-induced blood-oxygen-level dependent (BOLD) signal change using functional magnetic resonance imaging (fMRI) in rats receiving drug for the first time during the imaging session. Twenty-three male Long Evans rats underwent fMRI imaging and received an intravenous infusion of methamphetamine, cocaine, or saline. Anatomical and pharmacological fMRI (pfMRI) were performed on a 7T BioSpec dedicated research MR scanner under isoflurane gas (1.5-2%). After collecting baseline data for 10min, rats received drug over the next 10min for a total 40min scan time. Data were then preprocessed and statistically analyzed in anatomically defined regions of interest (ROIs) that have been implicated in persistent drug seeking and relapse. Methamphetamine during the imaging session resulted in a sustained negative BOLD signal change in key regions of the relapse circuit, except for the prefrontal cortex. In contrast, cocaine evoked a positive or unchanged BOLD signal in these same regions. In all of the investigated ROIs, there were no changes in BOLD signal following saline. Acute methamphetamine and cocaine have distinct patterns of functional activity as measured by pfMRI. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Functionalized nanoparticles based solid-phase membrane micro-tip extraction and high-performance liquid chromatography analyses of vitamin B complex in human plasma.

    PubMed

    Ali, Imran; Kulsum, Umma; Al-Othman, Zeid A; Alwarthan, Abdulrahman; Saleem, Kishwar

    2016-07-01

    Iron nanoparticles were prepared by a green method following functionalization using 1-butyl-3-methylimidazolium bromide. 1-Butyl-3-methylimidazole iron nanoparticles were characterized using FTIR spectroscopy, energy dispersive X-ray fluorescence, X-ray diffraction, scanning electron microscopy and transmission electron microscopy. The nanoparticles were used in solid-phase membrane micro-tip extraction to separate vitamin B complex from plasma before high-performance liquid chromatography. The optimum conditions obtained were sorbent (15 mg), agitation time (30 min), pH (9.0), desorbing solvent [water (5 mL) + methanol (5 mL) + sodium hydroxide (0.1 N) + acetic acid (d = 1.05 kg/L, pH 5.5), desorbing volume (10 mL) and desorption time (30 min). The percentage recoveries of all the eight vitamin B complex were from 60 to 83%. A high-performance liquid chromatography method was developed using a PhE column (250 × 4.6 mm, 5.0 μm) and water/acetonitrile (95:5, v/v; pH 4.0 with 0.1% formic acid) mobile phase. The flow rate was 1.0 mL/min with detection at 270 and 210 nm. The values of the capacity, separation and resolution factor were 0.57-39.47, 1.12-6.00 and 1.84-26.26, respectively. The developed sample preparation and chromatographic methods were fast, selective, inexpensive, economic and reproducible. The developed method can be applied for analyzing these drugs in biological and environmental matrices. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Cocaine and methamphetamine induce opposing changes in BOLD signal response in rats

    PubMed Central

    See, Ronald E.; Joseph, Jane E.; Reichel, Carmela M.

    2016-01-01

    Background Neuroimaging studies in psychostimulant addicts have reported functional neural activity changes in brain regions involved in relapse. However, the difference between the effects of the psychostimulants methamphetamine and cocaine on neuronal activity in a similar setting not been clarified. Since studies in humans are limited by the inability to study the initial impact of psychostimulant drugs, we addressed this issue in a rat model. Objective Here, we report methamphetamine and cocaine-induced blood-oxygen-level dependent (BOLD) signal change using functional magnetic resonance imaging (fMRI) in rats receiving drug for the first time during the imaging session. Methods Twenty-three male Long Evans rats underwent fMRI imaging and received an intravenous infusion of methamphetamine, cocaine, or saline. Anatomical and pharmacological fMRI (pfMRI) were performed on a 7T BioSpec dedicated research MR scanner under isoflurane gas (1.5-2%). After collecting baseline data for 10 min, rats received drug over the next 10 min for a total 40 min scan time. Data were then preprocessed and statistically analyzed in anatomically defined regions of interest (ROIs) that have been implicated in persistent drug seeking and relapse. Results Methamphetamine during the imaging session resulted in a sustained negative BOLD signal change in key regions of the relapse circuit, except for the prefrontal cortex. In contrast, cocaine evoked a positive or unchanged BOLD signal in these same regions. In all of the investigated ROIs, there were no changes in BOLD signal following saline. Conclusion Acute methamphetamine and cocaine have distinct patterns of functional activity as measured by pfMRI. PMID:27103569

  4. Surface modification of commercial seawater reverse osmosis membranes by grafting of hydrophilic monomer blended with carboxylated multiwalled carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Vatanpour, Vahid; Zoqi, Naser

    2017-02-01

    In this study, modification of commercial seawater reverse osmosis membranes was carried out with simultaneous use of surface grafting and nanoparticle incorporation. Membrane grafting with a hydrophilic acrylic acid monomer and thermal initiator was used to increase membrane surface hydrophilicity. The used nanomaterial was carboxylated multiwalled carbon nanotubes (MWCNTs), which were dispersed in the grafting solution and deposited on membrane surface to reduce fouling by creating polymer brushes and hydrodynamic resistance. Effectiveness of the grafting process (formation of graft layer on membrane surface) was proved by Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM) analyses. Increase of membrane surface hydrophilicity was approved with contact angle test. First, the grafting was performed on the membrane surfaces with different monomer concentrations, various contact times and several membrane curing times (three variables for optimization). The modified membranes were tested by a cross-flow setup using saline solution for permeability and rejection tests, and bovine serum albumin (BSA) solution for fouling test. The results showed that the modified membranes with 0.75 M of monomer, 3 min contact time and 80 min curing time in an oven at 50 °C presented the highest flux and lowest rejection decline related to the commercial reverse osmosis membrane. In the next step, the optimum grafting condition was selected and the nanotubes with different weight percentages were dispersed in the acrylic acid monomer solution. The membrane containing 0.25 wt% COOH-MWCNTs showed the highest fouling resistance.

  5. Dynamics of actin-based movement by Rickettsia rickettsii in vero cells.

    PubMed

    Heinzen, R A; Grieshaber, S S; Van Kirk, L S; Devin, C J

    1999-08-01

    Actin-based motility (ABM) is a virulence mechanism exploited by invasive bacterial pathogens in the genera Listeria, Shigella, and Rickettsia. Due to experimental constraints imposed by the lack of genetic tools and their obligate intracellular nature, little is known about rickettsial ABM relative to Listeria and Shigella ABM systems. In this study, we directly compared the dynamics and behavior of ABM of Rickettsia rickettsii and Listeria monocytogenes. A time-lapse video of moving intracellular bacteria was obtained by laser-scanning confocal microscopy of infected Vero cells synthesizing beta-actin coupled to green fluorescent protein (GFP). Analysis of time-lapse images demonstrated that R. rickettsii organisms move through the cell cytoplasm at an average rate of 4.8 +/- 0.6 micrometer/min (mean +/- standard deviation). This speed was 2.5 times slower than that of L. monocytogenes, which moved at an average rate of 12.0 +/- 3.1 micrometers/min. Although rickettsiae moved more slowly, the actin filaments comprising the actin comet tail were significantly more stable, with an average half-life approximately three times that of L. monocytogenes (100.6 +/- 19.2 s versus 33.0 +/- 7.6 s, respectively). The actin tail associated with intracytoplasmic rickettsiae remained stationary in the cytoplasm as the organism moved forward. In contrast, actin tails of rickettsiae trapped within the nucleus displayed dramatic movements. The observed phenotypic differences between the ABM of Listeria and Rickettsia may indicate fundamental differences in the mechanisms of actin recruitment and polymerization.

  6. Temperature dependent fabrication of cost-effective and nontoxic Cu{sub 2}ZnSnS{sub 4} (CZTS) thin films for solar cell

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Digraskar, Renuka, E-mail: renukad120@gmail.com; Sathe, Bhaskar, E-mail: bhaskarsathe@gmail.com; Gattu, Ketan

    2016-05-06

    In the present work, Cu{sub 2}ZnSnS{sub 4} (CZTS) thin films have been fabricated onto the glass substrate by simple and economic chemical bath deposition technique{sup 1}, and the effect of deposition temperature is reported. The deposition temperatures used were 50°C and 60°C for a deposition time of 60 min, which are significantly lower than earlier reports. These CZTS thin films were characterized for optical, electrical, morphological and elemental properties using, UV-Vis spectrophotometer, I-V system for photosensitivity, two probe resistivity system for resistivity, scanning electron microscopy, energy dispersive spectroscopy and Raman spectroscopy.

  7. Gold nanoparticle uptake in whole cells in liquid examined by environmental scanning electron microscopy.

    PubMed

    Peckys, Diana B; de Jonge, Niels

    2014-02-01

    The size of gold nanoparticles (AuNPs) can influence various aspects of their cellular uptake. Light microscopy is not capable of resolving most AuNPs, while electron microscopy (EM) is not practically capable of acquiring the necessary statistical data from many cells and the results may suffer from various artifacts. Here, we demonstrate the use of a fast EM method for obtaining high-resolution data from a much larger population of cells than is usually feasible with conventional EM. A549 (human lung carcinoma) cells were subjected to uptake protocols with 10, 15, or 30 nm diameter AuNPs with adsorbed serum proteins. After 20 min, 24 h, or 45 h, the cells were fixed and imaged in whole in a thin layer of liquid water with environmental scanning electron microscopy equipped with a scanning transmission electron microscopy detector. The fast preparation and imaging of 145 whole cells in liquid allowed collection of nanoscale data within an exceptionally small amount of time of ~80 h. Analysis of 1,041 AuNP-filled vesicles showed that the long-term AuNP storing lysosomes increased their average size by 80 nm when AuNPs with 30 nm diameter were uptaken, compared to lysosomes of cells incubated with AuNPs of 10 and 15 nm diameter.

  8. X-ray Photon Counting Using 100 MHz Ready-Made Silicon P-Intrinsic-N X-ray Diode and Its Application to Energy-Dispersive Computed Tomography

    NASA Astrophysics Data System (ADS)

    Kodama, Hajime; Watanabe, Manabu; Sato, Eiichi; Oda, Yasuyuki; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Kusachi, Shinya; Sato, Shigehiro; Ogawa, Akira

    2013-07-01

    X-ray photons are directly detected using a 100 MHz ready-made silicon P-intrinsic-N X-ray diode (Si-PIN-XD). The Si-PIN-XD is shielded using an aluminum case with a 25-µm-thick aluminum window and a BNC connector. The photocurrent from the Si-PIN-XD is amplified by charge sensitive and shaping amplifiers, and the event pulses are sent to a multichannel analyzer (MCA) to measure X-ray spectra. At a tube voltage of 90 kV, we observe K-series characteristic X-rays of tungsten. Photon-counting computed tomography (PC-CT) is accomplished by repeated linear scans and rotations of an object, and projection curves of the object are obtained by linear scanning at a tube current of 2.0 mA. The exposure time for obtaining a tomogram is 10 min with scan steps of 0.5 mm and rotation steps of 1.0°. At a tube voltage of 90 kV, the maximum count rate is 150 kcps. We carry out PC-CT using gadolinium media and confirm the energy-dispersive effect with changes in the lower level voltage of the event pulse using a comparator.

  9. Physicochemical Characterization of a Heat Treated Calcium Alginate Dry Film Prepared with Chicken Stock.

    PubMed

    Báez, Germán D; Piccirilli, Gisela N; Ballerini, Griselda A; Frattini, Agustín; Busti, Pablo A; Verdini, Roxana A; Delorenzi, Néstor J

    2017-04-01

    Solid sodium alginate was dissolved into chicken stock in order to give a final alginate concentration of 0.9 percent (w/v). Calcium ions present in chicken stock were enough to induce ionic gelation. After drying, Fourier transform infrared spectroscopy, thickness and mechanical properties of films obtained were determined. Calcium alginate-chicken stock films were heated at 130 °C for different times between 0 and 15 min. Mechanical and optical studies, differential scanning calorimetry, visual aspect and scanning electron microscopy were carried out to describe physicochemical properties of heat treated films. Heating developed a maroon ochre color and increased the brittleness (crispness) of the films related to the intensity of the treatment. Differential scanning thermometry and study on appearance of the films suggested that Maillard reactions may be responsible for the observed changes. Maillard reactions mainly occurred between reducing sugar monomers and free amino groups of gelatin peptides present in the chicken stock, and between alginate and gelatin peptides to a lesser extent. In addition, the plasticizing effect of fat added with chicken stock was also studied. These studies suggest a potential use of heat treated chicken stock films as a substitute of roasted chicken skin. © 2017 Institute of Food Technologists®.

  10. [Optimization of extraction technics of total saponins from Pulsatilla cernua].

    PubMed

    Li, Hai-Yan; Hao, Ning; Xu, Yong-Nan; Piao, Zhong-Yun

    2010-04-01

    The extraction condition of total saponins from Pulsatilla cenua by ultrasonic wave was optimized by single factor and orthogonal experiments. The largest absorbency of saponin was intended to be 470 nm by wavelength scan method with the pulchinenoside B4 as control sample, the linear relationship was observed between the absorbency and the content of saponin in the range of 0 - 0.040 mg/mL. The optimal conditions of extraction was as following: 80% of alcohol concentration, 40 min of ultrasonic time, 1: 20 of solid to liquid ratio, 80 W of ultrasonic power and one time for extraction. Among them, alcohol had the most significant effect on the extraction of total saponins. The content of total saponins in Pulsatilla cernua was 4. 32% under the optimal condition. The method developed here is efficient, stable, accurate and repeatable.

  11. Effect of austempering temperature and time on mechanical properties of SAE 9260 steel

    NASA Astrophysics Data System (ADS)

    Dalwatkar, Ranjit; Prabhu, N.; Singh, R. K. P.

    2018-04-01

    This work describes the effect of austempering heat treatment on microstrcuture and mechanical properties of SAE 9260 steel. Steel samples, austenitized at 900 °C for one hour, were isothermally heat treated in the temperature range 300,325 and 350 °C for different times. Microstructural characterization was carried out using optical and scanning electron microscopes. The microstructure of the austempered samples consisted of bainitic ferrite and retained austenite. The volume fraction of retained austenite was determined using X-ray diffraction. Isothermal heat treatment at 350 °C for 20 min, resulted in a retained austenite content of around 38% in the microstructure. Increase in isothermal transformation temperature led to an increase in the fraction of retained austenite. Also, good combination of strength and ductility was obtained in the samples with increased amounts of retained austenite.

  12. Automated tuning of an eight-channel cardiac transceive array at 7 tesla using piezoelectric actuators.

    PubMed

    Keith, Graeme A; Rodgers, Christopher T; Hess, Aaron T; Snyder, Carl J; Vaughan, J Thomas; Robson, Matthew D

    2015-06-01

    Ultra-high field (UHF) MR scanning in the body requires novel coil designs due to B1 field inhomogeneities. In the transverse electromagnetic field (TEM) design, maximum B1 transmit power can only be achieved if each individual transmit element is tuned and matched for different coil loads, which requires a considerable amount of valuable scanner time. An integrated system for autotuning a multichannel parallel transmit (pTx) cardiac TEM array was devised, using piezoelectric actuators, power monitoring equipment and control software. The reproducibility and performance of the system were tested and the power responses of the coil elements were profiled. An automated optimization method was devised and evaluated. The time required to tune an eight-element pTx cardiac RF array was reduced from a mean of 30 min to less than 10 min with the use of this system. Piezoelectric actuators are an attractive means of tuning RF coil arrays to yield more efficient B1 transmission into the subject. An automated mechanism for tuning these elements provides a practical solution for cardiac imaging at UHF, bringing this technology closer to clinical use. © 2014 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

  13. Dissolution of brominated epoxy resins by dimethyl sulfoxide to separate waste printed circuit boards.

    PubMed

    Zhu, Ping; Chen, Yan; Wang, Liangyou; Qian, Guangren; Zhang, Wei Jie; Zhou, Ming; Zhou, Jin

    2013-03-19

    Improved methods are required for the recycling of waste printed circuit boards (WPCBs). In this study, WPCBs (1-1.5 cm(2)) were separated into their components using dimethyl sulfoxide (DMSO) at 60 °C for 45 min and a metallographic microscope was used to verify their delamination. An increased incubation time of 210 min yielded a complete separation of WPCBs into their components, and copper foils and glass fibers were obtained. The separation time decreased with increasing temperature. When the WPCB size was increased to 2-3 cm(2), the temperature required for complete separation increased to 90 °C. When the temperature was increased to 135 °C, liquid photo solder resists could be removed from the copper foil surfaces. The DMSO was regenerated by rotary decompression evaporation, and residues were obtained. Fourier transform infrared spectroscopy (FT-IR), thermal analysis, nuclear magnetic resonance, scanning electron microscopy, and energy-dispersive X-ray spectroscopy were used to verify that these residues were brominated epoxy resins. From FT-IR analysis after the dissolution of brominated epoxy resins in DMSO it was deduced that hydrogen bonding may play an important role in the dissolution mechanism. This novel technology offers a method for separating valuable materials and preventing environmental pollution from WPCBs.

  14. Synthesis of seaweed based carbon acid catalyst by thermal decomposition of ammonium sulfate for biodiesel production

    NASA Astrophysics Data System (ADS)

    Ee, Tang Zo; Lim, Steven; Ling, Pang Yean; Huei, Wong Kam; Chyuan, Ong Hwai

    2017-04-01

    Experiment was carried out to study the feasibility of biomass derived solid acid catalyst for the production of biodiesel using Palm Fatty Acid Distillate (PFAD). Malaysia indigenous seaweed was selected as the biomass to be carbonized as the catalyst support. Sulfonation of seaweed based carbon material was carried out by thermal decomposition of ammonium sulfate, (NH4)2SO4. The effects of carbonization temperature at 200 to 600°C on the catalyst physical and chemical properties were studied. The effect of reaction parameters on the fatty acid methyl ester (FAME) yield was studied by varying the concentration of ammonium sulfate (5.0 to 40.0 w/v%) and thermal decomposition time (15 to 90 min). Characterizations of catalyst were carried out to study the catalyst surface morphology with Scanning Electron Microscope (SEM), acid density with back titration and functional group attached with FT-IR. Results showed that when the catalyst sulfonated with 10.0 w/v% ammonium sulfate solution and heated to 235°C for 30 min, the highest FAME yield achieved was 23.7% at the reaction condition of 5.0 wt.% catalyst loading, esterification time of 4 h, methanol to PFAD molar ratio of 20:1 at 100°C reaction temperature.

  15. Improvement of CO2/N2 separation performance by polymer matrix cellulose acetate butyrate

    NASA Astrophysics Data System (ADS)

    Lee, R. J.; Jawad, Z. A.; Ahmad, A. L.; Ngo, J. Q.; Chua, H. B.

    2017-06-01

    With the rapid development of modern civilization, carbon dioxide (CO2) is produced in large quantities and mainly generated from industrial sectors. The gas emission is the major contributor to global warming. To address this issue, the membrane technology is implemented for the CO2 removal, due to the energy efficiency and economic advantages presented. Cellulose acetate butyrate (CAB) is selected as the polymeric material, due to the excellent film-forming properties and capable of developing a defect-free layer of neat membrane. This study described the fabrication development of CAB using a wet phase inversion method with different casting conditions. Where the composition of the casting solutions (3-5 wt %) and solvent evaporation time (4-6 min) were determined. The outcomes of these dominant parameters were then used to determine the best CAB membrane for CO2/Nitrogen (N2) separation and supported by the characterization i.e. scanning electron micrograph. Gas permeation measurements showed satisfactory performance for CAB membrane fabricated with 5 min evaporation time and 4 wt% polymer composition (M2). Where, its permeance and selectivity are 120.19 GPU and 3.17, respectively. In summary, this study showed a brief outlined of the future direction and perspective of CAB membrane for CO2/N2 separation.

  16. On the influence of DC electric fields on the aerosol assisted chemical vapor deposition growth of photoactive titanium dioxide thin films.

    PubMed

    Romero, Luz; Binions, Russell

    2013-11-05

    Titanium dioxide thin films were deposited on fluorine doped tin oxide glass substrate from the electric field assisted aerosol chemical vapor deposition (EACVD) reaction of titanium isopropoxide (TTIP, Ti(OC3H7)4) in toluene on glass substrates at a temperature of 450 °C. DC electric fields were generated by applying a potential difference between the electrodes of the transparent coated oxide coated glass substrates during the deposition. The deposited films were characterized using scanning electron microscopy, X-ray diffraction, atomic force microscopy, Raman spectroscopy, and UV-vis spectroscopy. The photoactivity and hydrophilicity of the deposited films were also analyzed using a dye-ink test and water-contact angle measurements. The characterization work revealed that the incorporation of DC electric fields produced significant reproducible changes in the film microstructure, preferred crystallographic orientation, roughness, and film thickness. Photocatalytic activity was calculated from the half-time (t1/2) or time taken to degrade 50% of the initial resazurin dye concentration. A large improvement in photocatalytic activity was observed for films deposited using an electric field with a strong orientation in the (004) direction (t1/2 17 min) as compared to a film deposited with no electric field (t1/2 40 min).

  17. Computer tomography prototyping and virtual procedure simulation in difficult cases of hip replacement surgery.

    PubMed

    Parchi, Paolo Domenico; Ferrari, Vincenzo; Piolanti, Nicola; Andreani, Lorenzo; Condino, Sara; Evangelisti, Gisberto; Lisanti, Michele

    2013-09-01

    Each year approximately 1 million total hip replacements (THR) are performed worldwide. A percentage of failure due to surgical approach and imprecise implant placement still exists. These result in several serious complications. We propose an approach to plan, to simulate, and to assist prosthesis implantation for difficult cases of THR based on 3-D virtual models, generated by segmenting patients' CT images, 3-D solid models, obtained by rapid prototyping (RP), and virtual procedure simulation. We carried out 8 THR with the aid of 3-D reconstruction and RP. After each procedure a questionnaire was submitted to the surgeon to assess the perceived added value of the technology. In all cases, the surgeon evaluated the 3-D model as useful in order to perform the planning. The clinical results showed a mean increase in the Harris Hip Score of about 42.5 points. The mean time of prototyping was 7.3 hours, (min 3.5 hours, max 9.3 hours). The mean surgery time was 65 minutes (min 50 minutes, max 88 minutes). Our study suggests that meticulous preoperative planning is necessary in front of a great aberration of the joint and in absence of normal anatomical landmarks, CT scan is mandatory, and 3-D reconstruction with solid model is useful.

  18. Erosion performance studies on sansevieria cylindrica reinforced vinylester composite

    NASA Astrophysics Data System (ADS)

    Johnson, R. Deepak Joel; Arumugaprabu, V.; Uthayakumar, M.; Vigneshwaran, S.; Manikandan, V.; Bennet, C.

    2018-03-01

    The intent of the research is to study the erosion behaviour of NaOH treated and untreated sansevieria cylindrica reinforced vinyl ester composites (SCVEC). The SCVEC was fabricated by varying fiber length as 30 mm and 40 mm and the fiber concentration as 30 wt%, 40 wt% and 50 wt% respectively for both NaOH treated and untreated sansevieria cylindrica fibres. The fabricated SCVEC was subjected to erosion studies using abrasive air jet erosion test rig. Full factorial design of experiment for conducting the erosion studies was made using Taguchi technique. The erosion test process variables like impingement angle 30°, 60° and 90°, impact velocity 28, 41 and 72 m s‑1, erodent feed rate or discharge 2.5, 3.3 and 4 g min‑1 and exposure time 5, 10 and 15 min were used to study the erosion rate of the SCVEC specimen. From the Taguchi analysis the optimized erosion process parameter and fabrication process parameters were found to be as fiber length 30 mm, NaOH treated fiber, fiber content 40 wt.%, impingement angle 90°, impact velocity 41 m s‑1, erodent discharge 4 g min‑1 and exposure time 15 min. Further, the erosion mechanism on the surface of the eroded SCVEC specimen was studied using Scanning electron microscope (SEM).

  19. Automated Microflow NMR: Routine Analysis of Five-Microliter Samples

    PubMed Central

    Jansma, Ariane; Chuan, Tiffany; Geierstanger, Bernhard H.; Albrecht, Robert W.; Olson, Dean L.; Peck, Timothy L.

    2006-01-01

    A microflow CapNMR probe double-tuned for 1H and 13C was installed on a 400-MHz NMR spectrometer and interfaced to an automated liquid handler. Individual samples dissolved in DMSO-d6 are submitted for NMR analysis in vials containing as little as 10 μL of sample. Sets of samples are submitted in a low-volume 384-well plate. Of the 10 μL of sample per well, as with vials, 5 μL is injected into the microflow NMR probe for analysis. For quality control of chemical libraries, 1D NMR spectra are acquired under full automation from 384-well plates on as many as 130 compounds within 24 h using 128 scans per spectrum and a sample-to-sample cycle time of ∼11 min. Because of the low volume requirements and high mass sensitivity of the microflow NMR system, 30 nmol of a typical small molecule is sufficient to obtain high-quality, well-resolved, 1D proton or 2D COSY NMR spectra in ∼6 or 20 min of data acquisition time per experiment, respectively. Implementation of pulse programs with automated solvent peak identification and suppression allow for reliable data collection, even for samples submitted in fully protonated DMSO. The automated microflow NMR system is controlled and monitored using web-based software. PMID:16194121

  20. Cationic polyelectrolyte functionalized magnetic particles assisted highly sensitive pathogens detection in combination with polymerase chain reaction and capillary electrophoresis.

    PubMed

    Chen, Jia; Lin, Yuexin; Wang, Yu; Jia, Li

    2015-06-01

    Pathogenic bacteria cause significant morbidity and mortality to humans. There is a pressing need to establish a simple and reliable method to detect them. Herein, we show that magnetic particles (MPs) can be functionalized by poly(diallyl dimethylammonium chloride) (PDDA), and the particles (PDDA-MPs) can be utilized as adsorbents for capture of pathogenic bacteria from aqueous solution based on electrostatic interaction. The as-prepared PDDA-MPs were characterized by Fourier-transform infrared spectroscopy, zeta potential, vibrating sample magnetometry, X-ray diffraction spectrometry, scanning electron microscopy, and transmission electron microscopy. The adsorption equilibrium time can be achieved in 3min. According to the Langmuir adsorption isotherm, the maximum adsorption capacities for E. coli O157:H7 (Gram-negative bacteria) and L. monocytogenes (Gram-positive bacteria) were calculated to be 1.8×10(9) and 3.1×10(9)cfumg(-1), respectively. The bacteria in spiked mineral water (1000mL) can be completely captured when applying 50mg of PDDA-MPs and an adsorption time of 5min. In addition, PDDA-MPs-based magnetic separation method in combination with polymerase chain reaction and capillary electrophoresis allows for rapid detection of 10(1)cfumL(-1) bacteria. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Assessment of 10B concentration in boron neutron capture therapy: potential of image-guided therapy using 18FBPA PET.

    PubMed

    Shimosegawa, Eku; Isohashi, Kayako; Naka, Sadahiro; Horitsugi, Genki; Hatazawa, Jun

    2016-12-01

    In boron neutron capture therapy (BNCT) for cancer, the accurate estimation of 10 B tissue concentrations, especially in neighboring normal organs, is important to avoid adverse effects. The 10 B concentration in normal organs after loading with 10 B, however, has not been established in humans. In this study, we performed 4-borono-2-[ 18 F]-fluoro-phenylalanine ( 18 FBPA) PET in healthy volunteers and estimated the chronological changes in the 10 B concentrations of normal organs. In 6 healthy volunteers, whole-body 18 FBPA PET scans were repeated 7 times during 1 h, and the mean 18 FBPA distributions of 13 organs were measured. Based on the 18 FBPA PET data, we then estimated the changes in the 10 B concentrations of the organs when the injection of a therapeutic dose of 10 BPA-fructose complex ( 10 BPA-fr; 30 g, 500 mg/kg body weight) was assumed. The maximum mean 18 FBPA concentrations were reached at 2-6 min after injection in all the organs except the brain and urinary bladder. The mean 18 FBPA concentration in normal brain plateaued at 24 min after injection. When the injection of a therapeutic dose of 10 BPA-fr was assumed, the estimated mean 10 B concentration in the kidney increased to 126.1 ± 24.2 ppm at 3 min after injection and then rapidly decreased to 30.9 ± 7.4 ppm at 53 min. The estimated mean 10 B concentration in the bladder gradually increased and reached 383.6 ± 214.7 ppm at 51 min. The mean 10 B concentration in the brain was estimated to be 7.6 ± 1.5 ppm at 57 min. 18 FBPA PET has a potential to estimate 10 B concentration of normal organs before neutron irradiation of BNCT when several assumptions are validated in the future studies.

  2. A comparison of the health benefits of reduced-exertion high-intensity interval training (REHIT) and moderate-intensity walking in type 2 diabetes patients.

    PubMed

    Ruffino, José S; Songsorn, Preeyaphorn; Haggett, Malindi; Edmonds, Daniel; Robinson, Anthony M; Thompson, Dylan; Vollaard, Niels B J

    2017-02-01

    Reduced-exertion high-intensity interval training (REHIT) is a genuinely time-efficient intervention that can improve aerobic capacity and insulin sensitivity in sedentary individuals. The present study compared the effects of REHIT and moderate-intensity walking on health markers in patients with type 2 diabetes (T2D) in a counter-balanced crossover study. Sixteen men with T2D (mean ± SD age: 55 ± 5 years, body mass index: 30.6 ± 2.8 kg·m -2 , maximal aerobic capacity: 27 ± 4 mL·kg -1 ·min -1 ) completed 8 weeks of REHIT (three 10-min low-intensity cycling sessions/week with two "all-out" 10-20-s sprints) and 8 weeks of moderate-intensity walking (five 30-min sessions/week at an intensity corresponding to 40%-55% of heart-rate reserve), with a 2-month wash-out period between interventions. Before and after each intervention, participants underwent an incremental fitness test, an oral glucose tolerance test (OGTT), a whole-body dual-energy X-ray absorptiometry scan, and continuous glucose monitoring. REHIT was associated with a significantly larger increase in maximal aerobic capacity compared with walking (7% vs. 1%; time × intervention interaction effect: p < 0.05). Both REHIT and walking decreased resting mean arterial pressure (-4%; main effect of time: p < 0.05) and plasma fructosamine (-5%; main effect of time: p < 0.05). Neither intervention significantly improved OGTT-derived measures of insulin sensitivity, glycaemic control measured using continuous glucose monitors, blood lipid profile, or body composition. We conclude that REHIT is superior to a 5-fold larger volume of moderate-intensity walking in improving aerobic fitness, but similar to walking REHIT is not an effective intervention for improving insulin sensitivity or glycaemic control in T2D patients in the short term.

  3. Surface degradation of glass ceramics after exposure to acidulated phosphate fluoride.

    PubMed

    Ccahuana, Vanessa Zulema S; Ozcan, Mutlu; Mesquita, Alfredo Mikail Melo; Nishioka, Renato Sussumo; Kimpara, Estevão Tomomitsu; Bottino, Marco Antonio

    2010-01-01

    This study evaluated the surface degradation effect of acidulated phosphate fluoride (APF) gel exposure on the glassy matrix ceramics as a function of time. Disc-shaped ceramic specimens (N = 120, 10/per ceramic material) were prepared in stainless steel molds (inner diameter: 5 mm, height: 2 mm) using 6 dental ceramics: 3 indicated for ceramic-fused-to-metal (Vita Omega 900, Carmen and Vita Titankeramik), 2 for all-ceramic (Vitadur Alpha and Finesse Low Fusing) and 1 for both types of restorations (IPS d.SIGN). The specimens were wet ground finished, ultrasonically cleaned and auto-glazed. All specimens were subjected to calculation of percentage of mass loss, surface roughness analysis and topographical description by scanning electron microscopy (SEM) before (0 min) and after exposure to 1.23 % APF gel for 4 min and 60 min representing short- and long-term etching effect, respectively. The data were analyzed using two-way ANOVA with repeated measures and Tukey's test (a=0.05). Significant effect of the type of the ceramics (p=0.0000, p=0.0031) and exposure time (p=0.0000) was observed in both surface roughness and percentage of mass loss values, respectively. The interaction factor between both parameters was also significant for both parameters (p=0.0904, p=0.0258). Both 4 min (0.44+/-0.1 - 0.81+/-0.2 microm) and 60 min (0.66+/-0.1 - 1.04+/-0.3 microm) APF gel exposure created significantly more surface roughness for all groups when compared to the control groups (0.33+/-0.2 - 0.68+/-0.2 microm) (p<0.05). There were no significant differences in percentage of mass loss between the ceramics at 4 min (p>0.05) but at 60 min exposure, IPS d.SIGN showed the highest percentage of mass loss (0.1151+/-0.11). The mean surface roughness for Vita Titankeramik (0.84+/-0.2 microm) and Finesse Low Fusing (0.74.+/-0.2 microm) was significantly higher than those of the other ceramics (0.59+/-0.1 microm - 0.49+/-0.1 microm) and Vita Titankeramik (p<0.05) regardless of the exposure time. A positive correlation was found between surface roughness and percentage of mass loss for all ceramic materials [(r=0.518 (Vitadur Alpha), r=0.405 (Vita Omega 900), r=0.580 (Carmen), r=0.687 (IPS d.SIGN), r=0.442 (Finesse Low Fusing), r=0.572 (Vita Titankeramik), Pearson's correlation coefficient)]. The qualitative SEM analysis showed evidence of corrosive attack on all of ceramics at varying degrees. The ceramics indicated for either metal-ceramic or all-ceramic restorations were all vulnerable to surface texture changes and mass loss after short-term and long-term APF gel exposure.

  4. Occurrence of amylose-lipid complexes in teff and maize starch biphasic pastes.

    PubMed

    Wokadala, Obiro Cuthbert; Ray, Suprakas Sinha; Emmambux, Mohammad Naushad

    2012-09-01

    The occurrence of amylose-lipid complexes was determined in maize and teff starch biphasic pastes i.e. peak viscosity pastes at short and prolonged pasting times. Maize and teff starches were pasted for 11.5 and 130 min with or without added stearic acid followed by thermo-stable alpha-amylase hydrolysis in a rapid visco-analyzer. X-ray diffraction analysis of pastes before and residues after hydrolysis showed crystalline V-amylose diffraction patterns for the starches pasted for a prolonged time with added stearic acid while less distinct V-amylose patterns with non-complexed stearic acid peaks were observed with a short pasting time. Differential scanning calorimetry of pastes before and residues after paste hydrolysis showed that Type I amylose-lipid complexes were formed after pasting for the short duration with added stearic acid, while Type II complexes are formed after pasting for the prolonged time. The present research provides evidence that amylose-lipid complexes play an important role in starch biphasic pasting. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. A safety study in vitro for the effects of an in-office bleaching system on the integrity of enamel and dentine.

    PubMed

    Sulieman, M; Addy, M; Macdonald, E; Rees, J S

    2004-09-01

    The aim of this study was to investigate safety concerns with bleaching procedures by studying the effects of a high concentration hydrogen peroxide (HP) in-surgery bleaching product on enamel and dentine. Flat enamel and dentine samples embedded in epoxy resin were prepared from human third molar teeth. Erosion of enamel: groups of enamel samples were treated with 35% HP then citric acid (CA) or brushing with toothpaste or CA alone and water alone. Enamel Loss was measured using a profilometer. Abrasion/erosion of dentine: groups of dentine specimens were treated as follows: Group 1--brushed with water for 30 min. Group 2--brushed with 35% HP for 30 min. Group 3--power bleached for 30 min and then Group 4--brushed with toothpaste for 1 minute. Group 5--water soaked for 30 min followed by brushing with toothpaste for 1 min. Group 6--orange juice soaked for 30 min followed by brushing with toothpaste for 1 min. Treatment effects were measured using a profilometer. Hardness tests: enamel and dentine specimens were hardness tested using a Wallace indenter prior to and post bleaching. Scanning Electron Microscopy: enamel and dentine specimens were taped and the exposed tissue treated with 35% HP and then studied under scanning electronmicroscopy (SEM). Enamel erosion: bleaching enamel samples had no measurable effect on enamel. Pre-bleaching had no significant effect on subsequent CA erosion or brushing. Abrasion/erosion of dentine: no significant differences were found between treatments 1-5 with little change from baseline detected. Orange juice (Group 6) produced considerable and significantly more erosion than other treatments. Hardness tests: there were no significant changes in hardness values for enamel and dentine. SEM: there was no evidence of any topographical changes to either enamel or dentine. Using one of the highest concentrations of HP for tooth bleaching procedures and maximum likely peroxide exposure, there was no evidence of deleterious effects on enamel or dentine. It must be assumed that studies which reported adverse effects on enamel and or dentine of bleaches reflect not the bleach itself but the pH of the formulation used.

  6. Quantification of 18F-Fluoride Kinetics: Evaluation of Simplified Methods.

    PubMed

    Raijmakers, Pieter; Temmerman, Olivier P P; Saridin, Carrol P; Heyligers, Ide C; Becking, Alfred G; van Lingen, Arthur; Lammertsma, Adriaan A

    2014-07-01

    (18)F-fluoride PET is a promising noninvasive method for measuring bone metabolism and bone blood flow. The purpose of this study was to assess the performance of various clinically useful simplified methods by comparing them with full kinetic analysis. In addition, the validity of deriving bone blood flow from K1 of (18)F-fluoride was investigated using (15)O-H2O as a reference. Twenty-two adults (mean age ± SD, 44.8 ± 25.2 y), including 16 patients scheduled for bone surgery and 6 healthy volunteers, were studied. All patients underwent dynamic (15)O-H2O and (18)F-fluoride scans before surgery. Ten of these patients had serial PET measurements before and at 2 time points after local bone surgery. During all PET scans, arterial blood was monitored continuously. (18)F-fluoride data were analyzed using nonlinear regression (NLR) and several simplified methods (Patlak and standardized uptake value [SUV]). SUV was evaluated for different time intervals after injection and after normalizing to body weight, lean body mass, and body surface area, and simplified measurements were compared with NLR results. In addition, changes in SUV and Patlak-derived fluoride influx rate (Ki) after surgery were compared with corresponding changes in NLR-derived Ki. Finally, (18)F-fluoride K1 was compared with bone blood flow derived from (15)O-H2O data, using the standard single-tissue-compartment model. K1 of (18)F-fluoride correlated with measured blood flow, but the correlation coefficient was relatively low (r = 0.35, P < 0.001). NLR resulted in a mean Ki of 0.0160 ± 0.0122, whereas Patlak analysis, for the interval 10-60 min after injection, resulted in an almost-identical mean Ki of 0.0161 ± 0.0117. The Patlak-derived Ki, for 10-60 min after injection, showed a high correlation with the NLR-derived Ki (r = 0.976). The highest correlation between Ki and lean body mass-normalized SUV was found for the interval 50-60 min (r = 0.958). Finally, changes in SUV correlated significantly with those in Ki (r = 0.97). The present data support the use of both Patlak and SUV for assessing fluoride kinetics in humans. However, (18)F-fluoride PET has only limited accuracy in monitoring bone blood flow. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  7. HeinzelCluster: accelerated reconstruction for FORE and OSEM3D.

    PubMed

    Vollmar, S; Michel, C; Treffert, J T; Newport, D F; Casey, M; Knöss, C; Wienhard, K; Liu, X; Defrise, M; Heiss, W D

    2002-08-07

    Using iterative three-dimensional (3D) reconstruction techniques for reconstruction of positron emission tomography (PET) is not feasible on most single-processor machines due to the excessive computing time needed, especially so for the large sinogram sizes of our high-resolution research tomograph (HRRT). In our first approach to speed up reconstruction time we transform the 3D scan into the format of a two-dimensional (2D) scan with sinograms that can be reconstructed independently using Fourier rebinning (FORE) and a fast 2D reconstruction method. On our dedicated reconstruction cluster (seven four-processor systems, Intel PIII@700 MHz, switched fast ethernet and Myrinet, Windows NT Server), we process these 2D sinograms in parallel. We have achieved a speedup > 23 using 26 processors and also compared results for different communication methods (RPC, Syngo, Myrinet GM). The other approach is to parallelize OSEM3D (implementation of C Michel), which has produced the best results for HRRT data so far and is more suitable for an adequate treatment of the sinogram gaps that result from the detector geometry of the HRRT. We have implemented two levels of parallelization for four dedicated cluster (a shared memory fine-grain level on each node utilizing all four processors and a coarse-grain level allowing for 15 nodes) reducing the time for one core iteration from over 7 h to about 35 min.

  8. Self-assembled nanoparticle arrays as nanomasks for pattern transfer

    NASA Astrophysics Data System (ADS)

    Sachan, M.; Bonnoit, C.; Hogg, C.; Evarts, E.; Bain, J. A.; Majetich, S. A.; Park, J.-H.; Zhu, J.-G.

    2008-07-01

    Argon ion milling was used to transfer the pattern of sparse 12 nm iron oxide nanoparticles into underlying thin films of Pt and magnetic tunnel junction stacks and quantify their etching rates and morphological evolution. Under typical milling conditions, Pt milled at 10 nm min-1, while the isolated particles of iron oxide used for the mask milled at 5 nm min-1. Dilute dispersions of nanoparticles were used to produce the sparse nanomasks, and high resolution scanning electron microscopy (SEM) and atomic force microscopy were used to monitor the evolution of etched structures as a function of milling time. SEM measurements indicate an apparent 20% increase in feature diameter before the features began to diminish under additional milling, suggesting redeposition as a limiting feature in the milling of dense arrays. Simulations of the milling process in nanoparticle arrays that include redeposition are consistent with this observation. These simulations predict that an edge-to-edge spacing of 3 nm in a dense array is feasible, but that redeposition reduces the final structure aspect ratio from that of the masking array by as much as a factor of two.

  9. Effect of (18)F-fluorodeoxyglucose extravasation on time taken for tumoral uptake to reach a plateau: animal and clinical PET analyses.

    PubMed

    Lee, Jong Jin; Chung, Jin Hwa; Kim, Seog-Young

    2016-10-01

    The present study aimed to investigate the effect of (18)F-fluorodeoxyglucose (FDG) extravasation on the time taken for tumoral uptake to reach a plateau. For the animal experiment, FDG extravasation was conducted in the tails of HCT116 tumor-bearing xenograft mice models in three groups (no extravasation, 40 % extravasation, and 80 % extravasation; n = 5, each). Dynamic positron emission tomography (PET) images were acquired over a period of 2 h following injection. Time-activity curves for FDG in the tails and tumors were calculated. For the clinical experiment, 22 patients (male:female, 14:8; age range, 70.8 ± 9.2 years) were subjected to PET/computed tomography (PET/CT) 1 h after the injection of FDG. The inclusion criteria were as follows: (1) submitted to both whole-body and subsequent regional scanning; (2) entire extravasation activity visualized in the whole-body images; (3) tumor visualized on both whole-body and additional regional images; and (4) status of tumor either confirmed by biopsy or clinically suspected for malignancy. The standardized uptake values (SUVs) of the tumors (on the whole-body and additional PET images) and extravasation sites were recorded. There were no significant differences in the time taken for tumoral uptake to reach a plateau and that to reach minimum activity at the extravasation site among the three groups of mice. However, the mean tumoral activity and activity at the extravasation site were negatively correlated at 1 h post-injection. According to the clinical PET findings, the differences in SUV between the whole-body and regional images were not significantly correlated with the interval between injection of FDG and start of whole-body scanning, interval between the start of whole-body scanning and start of regional scanning, extravasation volume, maximum SUV of the extravasation site, or total activity at the extravasation site. The time taken for tumoral uptake to reach a plateau is not affected by extravasation, even at extensive degrees. Thus, in routine practice, the imaging time of approximately 60 min post-injection need not be modified even if extravasation is identified. However, tumor SUV may be underestimated in cases of extravasation.

  10. Quantification of left ventricular functional parameter values using 3D spiral bSSFP and through-time non-Cartesian GRAPPA.

    PubMed

    Barkauskas, Kestutis J; Rajiah, Prabhakar; Ashwath, Ravi; Hamilton, Jesse I; Chen, Yong; Ma, Dan; Wright, Katherine L; Gulani, Vikas; Griswold, Mark A; Seiberlich, Nicole

    2014-09-11

    The standard clinical acquisition for left ventricular functional parameter analysis with cardiovascular magnetic resonance (CMR) uses a multi-breathhold multi-slice segmented balanced SSFP sequence. Performing multiple long breathholds in quick succession for ventricular coverage in the short-axis orientation can lead to fatigue and is challenging in patients with severe cardiac or respiratory disorders. This study combines the encoding efficiency of a six-fold undersampled 3D stack of spirals balanced SSFP sequence with 3D through-time spiral GRAPPA parallel imaging reconstruction. This 3D spiral method requires only one breathhold to collect the dynamic data. Ten healthy volunteers were recruited for imaging at 3 T. The 3D spiral technique was compared against 2D imaging in terms of systolic left ventricular functional parameter values (Bland-Altman plots), total scan time (Welch's t-test) and qualitative image rating scores (Wilcoxon signed-rank test). Systolic left ventricular functional values were not significantly different (i.e. 3D-2D) between the methods. The 95% confidence interval for ejection fraction was -0.1 ± 1.6% (mean ± 1.96*SD). The total scan time for the 3D spiral technique was 48 s, which included one breathhold with an average duration of 14 s for the dynamic scan, plus 34 s to collect the calibration data under free-breathing conditions. The 2D method required an average of 5 min 40s for the same coverage of the left ventricle. The difference between 3D and 2D image rating scores was significantly different from zero (Wilcoxon signed-rank test, p < 0.05); however, the scores were at least 3 (i.e. average) or higher for 3D spiral imaging. The 3D through-time spiral GRAPPA method demonstrated equivalent systolic left ventricular functional parameter values, required significantly less total scan time and yielded acceptable image quality with respect to the 2D segmented multi-breathhold standard in this study. Moreover, the 3D spiral technique used just one breathhold for dynamic imaging, which is anticipated to reduce patient fatigue as part of the complete cardiac examination in future studies that include patients.

  11. Sterilization effects of atmospheric cold plasma brush

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Q.S.; Huang, C.; Hsieh, F.-H.

    2006-01-02

    This study investigated the sterilization effects of a brush-shaped plasma created at one atmospheric pressure. A population of 1.0x10{sup 4}-1.0x10{sup 5} Escherichia coli or Micrococcus luteus bacteria was seeded in filter paper media and then subjected to Ar and/or Ar+O{sub 2} plasmas. A complete kill of the Micrococcus luteus required about 3 min argon plasma exposures. With oxygen addition into the argon plasma gas streams, a complete kill of the bacteria needed only less than 1 min plasma exposure for Micrococcus luteus and about 2 min exposure for Escherichia coli. The plasma treatment effects on the different bacteria cell structuresmore » were examined using scanning electron microscopy.« less

  12. Rapid planar chromatographic analysis of 25 water-soluble dyes used as food additives.

    PubMed

    Morlock, Gertrud E; Oellig, Claudia

    2009-01-01

    A rapid planar chromatographic method for identification and quantification of 25 water-soluble dyes in food was developed. In a horizontal developing chamber, the chromatographic separation on silica gel 60F254 high-performance thin-layer chromatography plates took 12 min for 40 runs in parallel, using 8 mL ethyl acetate-methanol-water-acetic acid (65 + 23 + 11 + 1, v/v/v/v) mobile phase up to a migration distance of 50 mm. However, the total analysis time, inclusive of application and evaluation, took 60 min for 40 runs. Thus, the overall time/run can be calculated as 1.5 min with a solvent consumption of 200 microL. A sample throughput of 1000 runs/8 h day can be reached by switching between the working stations (application, development, and evaluation) in a 20 min interval, which triples the analysis throughput. Densitometry was performed by absorption measurement using the multiwavelength scan mode in the UV and visible ranges. Repeatabilities [relative standard deviation (RSD), 4 determinations] at the first or second calibration level showed precisions of mostly < or = 2.7%, ranging between 0.2 and 5.2%. Correlation coefficient values (R > or = 0.9987) and RSD values (< or = 4.2%) of the calibration curves were highly satisfactory using classical quantification. However, digital evaluation of the plate image was also used for quantification, which resulted in RSD values of the calibration curves of mostly < or = 3.0%, except for two < or = 6.0%. The method was applied for the analysis of some energy drinks and bakery ink formulations, directly applied after dilution. By recording of absorbance spectra in the visible range, the identities of the dyes found in the samples were ascertained by comparison with the respective standard bands (correlation coefficients > or = 0.9996). If necessary for confirmation, online mass spectra were recorded within a minute.

  13. Machinability of CAD-CAM materials.

    PubMed

    Chavali, Ramakiran; Nejat, Amir H; Lawson, Nathaniel C

    2017-08-01

    Although new materials are available for computer-aided design and computer-aided manufacturing (CAD-CAM) fabrication, limited information is available regarding their machinability. The depth of penetration of a milling tool into a material during a timed milling cycle may indicate its machinability. The purpose of this in vitro study was to compare the tool penetration rate for 2 polymer-containing CAD-CAM materials (Lava Ultimate and Enamic) and 2 ceramic-based CAD-CAM materials (e.max CAD and Celtra Duo). The materials were sectioned into 4-mm-thick specimens (n=5/material) and polished with 320-grit SiC paper. Each specimen was loaded into a custom milling apparatus. The apparatus pushed the specimens against a milling tool (E4D Tapered 2016000) rotating at 40 000 RPM with a constant force of 0.98 N. After a 6-minute timed milling cycle, the length of each milling cut was measured with image analysis software under a digital light microscope. Representative specimens and milling tools were examined with scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy. The penetration rate of Lava Ultimate (3.21 ±0.46 mm/min) and Enamic (2.53 ±0.57 mm/min) was significantly greater than that of e.max CAD (1.12 ±0.32 mm/min) or Celtra Duo (0.80 ±0.21 mm/min) materials. SEM observations showed little tool damage, regardless of material type. Residual material was found on the tools used with polymer-containing materials, and wear of the embedding medium was seen on the tools used with the ceramic-based materials. Edge chipping was noted on cuts made in the ceramic-based materials. Lava Ultimate and Enamic have greater machinability and less edge chipping than e.max CAD and Celtra Duo. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  14. Technical requirements for Na¹⁸F PET bone imaging of patients being treated using a Taylor spatial frame.

    PubMed

    Hatherly, Robert; Brolin, Fredrik; Oldner, Åsa; Sundin, Anders; Lundblad, Henrik; Maguire, Gerald Q; Jonsson, Cathrine; Jacobsson, Hans; Noz, Marilyn E

    2014-03-01

    Diagnosis of new bone growth in patients with compound tibia fractures or deformities treated using a Taylor spatial frame is difficult with conventional radiography because the frame obstructs the images and creates artifacts. The use of Na(18)F PET studies may help to eliminate this difficulty. Patients were positioned on the pallet of a clinical PET/CT scanner and made as comfortable as possible with their legs immobilized. One bed position covering the site of the fracture, including the Taylor spatial frame, was chosen for the study. A topogram was performed, as well as diagnostic and attenuation correction CT. The patients were given 2 MBq of Na(18)F per kilogram of body weight. A 45-min list-mode acquisition was performed starting at the time of injection, followed by a 5-min static acquisition 60 min after injection. The patients were examined 6 wk after the Taylor spatial frame had been applied and again at 3 mo to assess new bone growth. A list-mode reconstruction sequence of 1 × 1,800 and 1 × 2,700 s, as well as the 5-min static scan, allowed visualization of regional bone turnover. With Na(18)F PET/CT, it was possible to confirm regional bone turnover as a means of visualizing bone remodeling without the interference of artifacts from the Taylor spatial frame. Furthermore, dynamic list-mode acquisition allowed different sequences to be performed, enabling, for example, visualization of tracer transport from blood to the fracture site.

  15. Laparoscopic approach to Meckel's diverticulum.

    PubMed

    Papparella, Alfonso; Nino, Fabiano; Noviello, Carmine; Marte, Antonio; Parmeggiani, Pio; Martino, Ascanio; Cobellis, Giovanni

    2014-07-07

    To retrospective review the laparoscopic management of Meckel Diverticulum (MD) in two Italian Pediatric Surgery Centers. Between January 2002 and December 2012, 19 trans-umbilical laparoscopic-assisted (TULA) procedures were performed for suspected MD. The children were hospitalized for gastrointestinal bleeding and/or recurrent abdominal pain. Median age at diagnosis was 5.4 years (range 6 mo-15 years). The study included 15 boys and 4 girls. All patients underwent clinical examination, routine laboratory tests, abdominal ultrasound and technetium-99m pertechnetate scan, and patients with bleeding underwent gastrointestinal endoscopy. The abdominal exploration was performed with a 10 mm operative laparoscope. Pneumoperitoneum was established based on the body weight. Systematic overview of the peritoneal cavity allowed the ileum to be grasped with an atraumatic instrument. The complete exploration and surgical treatment of MD were performed extracorporeally, after intestinal exteriorization through the umbilicus. All patients' demographics, main clinical features, diagnostic investigations, operative time, histopathology reports, conversion rate, hospital stay and complications were registered and analyzed. MD was identified in 17 patients, while 1 had an ileal duplication and 1 a jejunal hemangioma. Fifteen patients had painless intestinal bleeding, while 4 had recurrent abdominal pain and exhibited cyst like structures in an ultrasound study. Eleven patients had a positive technetium-99m pertechnetate scan. In the patients with bleeding, gastrointestinal endoscopy did not name the source of hemorrhage. All patients were subjected to a TULA surgical procedure. An intestinal resection/anastomosis was performed in 14 patients, while 4 had a wedge resection of the diverticulum and 1 underwent stapling diverticulectomy. All surgical procedures were performed without conversion to open laparotomy. Mean operative time was 75 min (range 40-115 min). No major surgical complications were recorded. The median hospital stay was 5-7 d (range 4-13 d). All patients are asymptomatic at a median follow up of 4, 5 years (range 10 mo-10 years). Trans-umbilical laparoscopic-assisted Meckel's diverticulectomy is safe and effective in the treatment of MD, with excellent results.

  16. Onboard functional and molecular imaging: A design investigation for robotic multipinhole SPECT

    PubMed Central

    Bowsher, James; Yan, Susu; Roper, Justin; Giles, William; Yin, Fang-Fang

    2014-01-01

    Purpose: Onboard imaging—currently performed primarily by x-ray transmission modalities—is essential in modern radiation therapy. As radiation therapy moves toward personalized medicine, molecular imaging, which views individual gene expression, may also be important onboard. Nuclear medicine methods, such as single photon emission computed tomography (SPECT), are premier modalities for molecular imaging. The purpose of this study is to investigate a robotic multipinhole approach to onboard SPECT. Methods: Computer-aided design (CAD) studies were performed to assess the feasibility of maneuvering a robotic SPECT system about a patient in position for radiation therapy. In order to obtain fast, high-quality SPECT images, a 49-pinhole SPECT camera was designed which provides high sensitivity to photons emitted from an imaging region of interest. This multipinhole system was investigated by computer-simulation studies. Seventeen hot spots 10 and 7 mm in diameter were placed in the breast region of a supine female phantom. Hot spot activity concentration was six times that of background. For the 49-pinhole camera and a reference, more conventional, broad field-of-view (FOV) SPECT system, projection data were computer simulated for 4-min scans and SPECT images were reconstructed. Hot-spot localization was evaluated using a nonprewhitening forced-choice numerical observer. Results: The CAD simulation studies found that robots could maneuver SPECT cameras about patients in position for radiation therapy. In the imaging studies, most hot spots were apparent in the 49-pinhole images. Average localization errors for 10-mm- and 7-mm-diameter hot spots were 0.4 and 1.7 mm, respectively, for the 49-pinhole system, and 3.1 and 5.7 mm, respectively, for the reference broad-FOV system. Conclusions: A robot could maneuver a multipinhole SPECT system about a patient in position for radiation therapy. The system could provide onboard functional and molecular imaging with 4-min scan times. PMID:24387490

  17. Onboard functional and molecular imaging: A design investigation for robotic multipinhole SPECT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bowsher, James, E-mail: james.bowsher@duke.edu; Giles, William; Yin, Fang-Fang

    2014-01-15

    Purpose: Onboard imaging—currently performed primarily by x-ray transmission modalities—is essential in modern radiation therapy. As radiation therapy moves toward personalized medicine, molecular imaging, which views individual gene expression, may also be important onboard. Nuclear medicine methods, such as single photon emission computed tomography (SPECT), are premier modalities for molecular imaging. The purpose of this study is to investigate a robotic multipinhole approach to onboard SPECT. Methods: Computer-aided design (CAD) studies were performed to assess the feasibility of maneuvering a robotic SPECT system about a patient in position for radiation therapy. In order to obtain fast, high-quality SPECT images, a 49-pinholemore » SPECT camera was designed which provides high sensitivity to photons emitted from an imaging region of interest. This multipinhole system was investigated by computer-simulation studies. Seventeen hot spots 10 and 7 mm in diameter were placed in the breast region of a supine female phantom. Hot spot activity concentration was six times that of background. For the 49-pinhole camera and a reference, more conventional, broad field-of-view (FOV) SPECT system, projection data were computer simulated for 4-min scans and SPECT images were reconstructed. Hot-spot localization was evaluated using a nonprewhitening forced-choice numerical observer. Results: The CAD simulation studies found that robots could maneuver SPECT cameras about patients in position for radiation therapy. In the imaging studies, most hot spots were apparent in the 49-pinhole images. Average localization errors for 10-mm- and 7-mm-diameter hot spots were 0.4 and 1.7 mm, respectively, for the 49-pinhole system, and 3.1 and 5.7 mm, respectively, for the reference broad-FOV system. Conclusions: A robot could maneuver a multipinhole SPECT system about a patient in position for radiation therapy. The system could provide onboard functional and molecular imaging with 4-min scan times.« less

  18. Diffusion tensor spectroscopic imaging of the human brain in children and adults.

    PubMed

    Fotso, Kevin; Dager, Stephen R; Landow, Alec; Ackley, Elena; Myers, Orrin; Dixon, Mindy; Shaw, Dennis; Corrigan, Neva M; Posse, Stefan

    2017-10-01

    We developed diffusion tensor spectroscopic imaging (DTSI), based on proton-echo-planar-spectroscopic imaging (PEPSI), and evaluated the feasibility of mapping brain metabolite diffusion in adults and children. PRESS prelocalized DTSI at 3 Tesla (T) was performed using navigator-based correction of movement-related phase errors and cardiac gating with compensation for repetition time (TR) related variability in T 1 saturation. Mean diffusivity (MD) and fractional anisotropy (FA) of total N-acetyl-aspartate (tNAA), total creatine (tCr), and total choline (tCho) were measured in eight adults (17-60 years) and 10 children (3-24 months) using b max  = 1734 s/mm 2 , 1 cc and 4.5 cc voxel sizes, with nominal scan times of 17 min and 8:24 min. Residual movement-related phase encoding ghosting (PEG) was used as a regressor across scans to correct overestimation of MD. After correction for PEG, metabolite slice-averaged MD estimated at 20% PEG were lower (P < 0.042) for adults (0.17/0.20/0.18 × 10 -3 mm 2 /s) than for children (0.26/0.27/0.24 × 10 -3 mm 2 /s). Extrapolated to 0% PEG, the MD estimates decreased further (0.09/0.11/0.11 × 10 -3 mm 2 /s versus 0.15/0.16/0.15 × 10 -3 mm 2 /s). Slice-averaged FA of tNAA (P = 0.049), tCr (P = 0.067), and tCho (P = 0.003) were higher in children. This high-speed DTSI approach with PEG regression allows for estimation of metabolite MD and FA with improved tolerance to movement. Our preliminary data suggesting age-related changes support DTSI as a sensitive technique for investigating intracellular markers of biological processes. Magn Reson Med 78:1246-1256, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  19. Recovery of iron from cyanide tailings with reduction roasting-water leaching followed by magnetic separation.

    PubMed

    Zhang, Yali; Li, Huaimei; Yu, Xianjin

    2012-04-30

    Cyanide tailing is a kind of solid waste produced in the process of gold extraction from gold ore. In this paper, recovery of iron from cyanide tailings was studied with reduction roasting-water leaching process followed by magnetic separation. After analysis of chemical composition and crystalline phase, the effects of different parameters on recovery of iron were chiefly introduced. Systematic studies indicate that the high recovery rate and grade of magnetic concentrate of iron can be achieved under the following conditions: weight ratios of cyanide tailings/activated carbon/sodium carbonate/sodium sulfate, 100:10:3:10; temperature, 50 °C; time, 60 min at the reduction roasting stage; the liquid to solid ratio is 15:1 (ml/g), leaching at 60 °C for 5 min and stirring speed at 20 r/min at water-leaching; exciting current is 2A at magnetic separation. The iron grade of magnetic concentrate was 59.11% and the recovery ratio was 75.12%. The mineralography of cyanide tailings, roasted product, water-leached sample, magnetic concentrate and magnetic tailings were studied by X-ray powder diffraction (XRD) technique. The microstructures of above products except magnetic tailings were also analyzed by scanning electron microscope (SEM) and energy disperse spectroscopy (EDS) to help understand the mechanism. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. In vitro rapid intraoral adjustment of porcelain prostheses using a high-speed dental handpiece.

    PubMed

    Song, Xiao-Fei; Yin, Ling; Han, Yi-Gang; Wang, Hui

    2008-03-01

    In vitro rapid intraoral adjustment of porcelain prostheses was conducted using a high-speed dental handpiece and diamond bur. The adjustment process was characterized by measurement of removal forces and energy, with scanning electron microscopic (SEM) observation of porcelain debris, surfaces and subsurface damage produced as a function of operational feed rate. Finite element analysis (FEA) was applied to evaluate subsurface stress distributions and degrees of subsurface damage. The results show that an increase in feed rate resulted in increases in both tangential and normal forces (analysis of variance (ANOVA), P<0.01). When the feed rate approached the highest rate of 60mm min(-1) at a fixed depth of cut of 100microm, the tangential force was nearly seven times that at the lowest feed rate of 15mm min(-1). Consequently, the specific removal energy increased significantly (ANOVA, P<0.01), and the maximum depth of subsurface damage obtained was approximately 110 and 120microm at the highest feed rate of 60mm min(-1) using SEM and FEA, respectively. The topographies of both the adjusted porcelain surfaces and the debris demonstrate microscopically that porcelain was removed via brittle fracture and plastic deformation. Clinicians must be cautious when pursuing rapid dental adjustments, because high operational energy, larger forces and severe surface and subsurface damage can be induced.

  1. Particle-size distribution (PSD) of pulverized hair: A quantitative approach of milling efficiency and its correlation with drug extraction efficiency.

    PubMed

    Chagas, Aline Garcia da Rosa; Spinelli, Eliani; Fiaux, Sorele Batista; Barreto, Adriana da Silva; Rodrigues, Silvana Vianna

    2017-08-01

    Different types of hair were submitted to different milling procedures and their resulting powders were analyzed by scanning electron microscopy (SEM) and laser diffraction (LD). SEM results were qualitative whereas LD results were quantitative and accurately characterized the hair powders through their particle size distribution (PSD). Different types of hair were submitted to an optimized milling conditions and their PSD was quite similar. A good correlation was obtained between PSD results and ketamine concentration in a hair sample analyzed by LC-MS/MS. Hair samples were frozen in liquid nitrogen for 5min and pulverized at 25Hz for 10min, resulting in 61% of particles <104μm and 39% from 104 to 1000μm. Doing so, a 359% increment on ketamine concentration was obtained for an authentic sample extracted after pulverization comparing with the same sample cut in 1mm fragments. When milling time was extended to 25min, >90% of particles were <60μm and an additional increment of 52.4% in ketamine content was obtained. PSD is a key feature on analysis of pulverized hair as it can affect the method recovery and reproducibility. In addition, PSD is an important issue on sample retesting and quality control procedures. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Study of electroless Ni-W-P alloy coating on martensitic stainless steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nikitasari, Arini, E-mail: arini-nikitasari@yahoo.com; Mabruri, Efendi, E-mail: efendi-lipi@yahoo.com

    Electroless nickel phospor (Ni-P) is widely used in many industries due to their corrosion and wear resistance, coating uniformity, and ability to coat non-conductive surfaces. The unique properties of tungsten such as high hardness, higher melting point, lower coefficient of linear thermal expansion, and high tensile strength have created a lot of interest in developing ternary Ni-W-P alloys. This article presents the study of electroless Ni-W-P alloys coating using acid or alkaline bath on martensitic stainless steel. Nickel sulfate and sodium tungstate were used as nickel and tungsten sources, respectively, and sodium hypophosphite was used as a reducing agent. Acidmore » or alkaline bath refer to bath pH condition was adjusted by adding sulfuric acid. Martensitic stainless steel was immersed in Ni-W-P bath for 15, 30, and 60 minutes. The substrate of martensitic stainless steel was subjected to pre-treatment (polishing and cleaning) and activation prior to electroless plating. The plating characteristics were investigated for concentration ratio of nickel and hypophosphite (1:3), sodium tungstate concentration 0,1 M, immersion time (15 min, 30 min, 60 min), and bath condition (acid, alkaline). The electroless Ni-W-P plating was heat treated at 400°C for 1 hour. Deposits were characterized using scanning electron microscope (SEM) and corrosion measurement system (CMS).« less

  3. Co3O4/CoP composite hollow polyhedron: A superior catalyst with dramatic efficiency and stability for the room temperature reduction of 4-nitrophenol

    NASA Astrophysics Data System (ADS)

    Liu, Xing; Li, Xiangqing; Qin, Lixia; Mu, Jin; Kang, Shi-Zhao

    2018-03-01

    In the present work, Co3O4/CoP composite hollow polyhedrons were prepared and characterized with X-ray diffraction, scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy and N2 adsorption-desorption isotherms. Then, the catalytic activity of the as-prepared Co3O4/CoP hollow polyhedrons was evaluated for the borohydride-assisted reduction of 4-nitrophenol at room temperature. The results indicate that the as-prepared Co3O4/CoP hollow polyhedrons are an efficient recyclable catalyst for the reduction of 4-nitrophenol. When the 4-nitrophenol initial concentration is 1.0 × 10-4 mol L-1 (100 mL), almost 100% 4-nitrophenol can be reduced within 3 min in the presence of the Co3O4/CoP hollow polyhedrons. The apparent rate constant of the 4-nitrophenol reduction is 1.61 min-1 at room temperature, and the activity factor is about 5.37 × 104 mL min-1 g-1, which is almost two times higher than that over Ag nanoparticles. Finally, the catalytic mechanism was preliminarily discussed. It is found that CoP plays an important role in the catalytic process. Here, CoP serves as active sites, which leads to efficient formation of hydrogen atoms from BH4- and fast electron transfer.

  4. Preparation and characteristics of carbon-supported platinum catalyst and its application in the removal of phenolic pollutants in aqueous solution by microwave-assisted catalytic oxidation.

    PubMed

    Bo, Longli; Quan, Xie; Wang, Xiaochang; Chen, Shuo

    2008-08-30

    Granular activated carbon-supported platinum (Pt/GAC) catalysts were prepared by microwave irradiation and characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX) and X-ray diffraction (XRD). Pt particles dispersing onto the surface of GAC could be penetrated by microwave and acted as "reaction centre" in the degradations of p-nitrophenol (PNP) and pentachlorophenol (PCP) in aqueous solution by microwave-assisted catalytic oxidation. The reaction was carried out through a packed bed reactor under ambient pressure and continuous flow mode. Under the conditions of microwave power 400 W, influent flow 6.4 mL min(-1) and air flow 120 mL min(-1), phenolic solutions with high concentration (initial concentrations of PNP and PCP solutions were 1469 and 1,454 mg L(-1), respectively) were treated effectively by Pt/GAC, 86% PNP and 90% PCP were degraded and total organic carbon (TOC) removal reached 85% and 71%, respectively. Compared with GAC, loaded Pt apparently accelerated oxidative reaction so that Pt/GAC had a better degrading and mineralizing efficiencies for PNP. Hydraulic retention time was only 16 min in experiment, which was shortened greatly compared with catalytic wet air oxidation. Pyrolysis and oxidation of phenolic pollutants occurred simultaneously on the surface of Pt/GAC by microwave irradiation.

  5. Evaluation of a short dynamic 18F-fluoride PET/CT scanning method to assess bone metabolic activity in spinal orthopedics.

    PubMed

    Peters, Marloes J M; Wierts, Roel; Jutten, Elisabeth M C; Halders, Servé G E A; Willems, Paul C P H; Brans, Boudewijn

    2015-11-01

    A complication after spinal fusion surgery is pseudarthrosis, but its radiological diagnosis is of limited value. (18)F-fluoride PET with its ability to assess bone metabolism activity could be of value. The goal of this study was to assess the clinical feasibility of calculating the static standardized uptake value (SUV) from a short dynamic scan without the use of blood sampling, thereby obtaining all dynamic and static parameters in a scan of only 30 min. This approach was tested on a retrospective patient population with persisting pain after spinal fusion surgery. In 16 patients, SUVs (SUV max, SUV mean) and kinetic parameters (K 1, k 2, k 3, v b, K i,NLR, K 1/k 2, k 3/(k 2 + k 3), K i,patlak) were derived from static and dynamic PET/CT scans of operated and control regions of the spine, after intravenous administration of 156-214 MBq (18)F-fluoride. Parameter differences between control and operated regions, as well as between pseudarthrosis and fused segments were evaluated. SUVmean at 30 and 60 min was calculated from kinetic parameters obtained from the dynamic data set (SUV mean,2TCM). Agreement between measured and calculated SUVs was evaluated through Bland-Altman plots. Overall, statistically significant differences between control and operated regions were observed for SUV max, SUV mean, K i,NLR, K i,patlak, K 1/k 2 and k 3/(k 2 + k 3). Diagnostic CT showed pseudarthrosis in 6/16 patients, while in 10/16 patients, segments were fused. Of all parameters, only those regarding the incorporation of bone [K i,NLR, K i,patlak, k 3/(k 2 + k 3)] differed statistically significant in the intervertebral disc space between the pseudarthrosis and fused patients group. The mean values of the patient-specific blood clearance rate [Formula: see text] differed statistically significant between the pseudarthrosis and the fusion group, with a p value of 0.011. This may correspond with the lack of statistical significance of the SUV values between pseudarthrosis and fused patients. Bland-Altman plots show that calculated SUV mean,2TCM values corresponded well with the measured SUV mean values. This study shows the feasibility of a 30-min dynamic (18)F-fluoride PET/CT scanning and this may provide dynamic parameters clinically relevant to the diagnosis of pseudarthrosis.

  6. Relative plan robustness of step-and-shoot vs rotational intensity–modulated radiotherapy on repeat computed tomographic simulation for weight loss in head and neck cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomson, David J.; The University of Manchester, Manchester Academic Health Science Centre, Institute of Cancer Sciences, Manchester; Beasley, William J.

    Introduction: Interfractional anatomical alterations may have a differential effect on the dose delivered by step-and-shoot intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT). The increased degrees of freedom afforded by rotational delivery may increase plan robustness (measured by change in target volume coverage and doses to organs at risk [OARs]). However, this has not been evaluated for head and neck cancer. Materials and methods: A total of 10 patients who required repeat computed tomography (CT) simulation and replanning during head and neck IMRT were included. Step-and-shoot IMRT and VMAT plans were generated from the original planning scan. The initial andmore » second CT simulation scans were fused and targets/OAR contours transferred, reviewed, and modified. The plans were applied to the second CT scan and doses recalculated without repeat optimization. Differences between step-and-shoot IMRT and VMAT for change in target volume coverage and doses to OARs between first and second CT scans were compared by Wilcoxon signed rank test. Results: There were clinically relevant dosimetric changes between the first and the second CT scans for both the techniques (reduction in mean D{sub 95%} for PTV2 and PTV3, D{sub min} for CTV2 and CTV3, and increased mean doses to the parotid glands). However, there were no significant differences between step-and-shoot IMRT and VMAT for change in any target coverage parameter (including D{sub 95%} for PTV2 and PTV3 and D{sub min} for CTV2 and CTV3) or dose to any OARs (including parotid glands) between the first and the second CT scans. Conclusions: For patients with head and neck cancer who required replanning mainly due to weight loss, there were no significant differences in plan robustness between step-and-shoot IMRT and VMAT. This information is useful with increased clinical adoption of VMAT.« less

  7. Feasibility of triphasic CT with a modified two-point Patlak plot to determine spit kidney glomerular filtration rate in clinical practice.

    PubMed

    Zhang, Yu-Dong; Xue, Chen-Qi; Wu, Chen-Jiang; Tao, Jun; Zhou, Wan-Li; Shi, Hai-Bin

    2017-01-01

    To investigate whether triphasic CT with a simplified Patlak plot can be used in clinical practice for the estimate of split kidney glomerular filtration rate (SKGFR). The animal experiment included 15 rabbits that underwent 40 dynamic contrast-enhanced CT scans of the kidneys with 1.5 s time interval. Patlak-derived SKGFR was obtained using standard forty-point, two-point (unenhanced phase, arterial phase t α, and portovenous phase t β ), and a modified two-point (MTP) (unenhanced, t α , t β , and a virtual t τ [t τ  = (t α  + t β )/2]) image data, respectively. The MTP-Patlak plot approach was then validated in 13 patients who underwent a triphasic renal contrast-enhanced CT examination. SKGFR measured by 99 m Tc-DTPA clearance was as a standard reference. MTP-Patlak significantly reduced input function errors than two-point Patlak (21.1 ± 16.2 % vs 30.8 ± 15.2 %, p < 0.01) and showed good concordance with standard Patlak for measurement of SKGFR in animal experiment (1.20 ± 0.38 mL/g/min vs 1.51 ± 0.43 mL/g/min; linear correlation coefficient r = 0.87, p < 0.001). Human study showed that mean SKGFR was 45.7 mL/min (range, 26.5-86.2 mL/min) obtained from 99 m Tc-DTPA, and 38.2 mL/min (range, 18.6-79.3 mL/min) obtained from triphasic CT using MTP-Patlak plot. Linear correlation between the two methods was r = 0.75 (p < 0.01). The mean difference between SKGFRs as determined with the two methods was 7.4 ± 9.0 mL/min. The MTP-Patlak approach, featured with simplicity, is feasible in a clinically indicated CT examination for the evaluation of split renal function.

  8. Differential Scanning Calorimetric (DSC) Analysis of Rotary Nickel-Titanium (NiTi) Endodontic File (RNEF)

    NASA Astrophysics Data System (ADS)

    Wu, Ray Chun Tung; Chung, C. Y.

    2012-12-01

    To determine the variation of A f along the axial length of rotary nickel-titanium endodontic files (RNEF). Three commercial brands of 4% taper RNEF: GTX (#20, 25 mm, Dentsply Tulsa Dental Specialties, Tulsa, OK, USA), K3 (#25, 25 mm) and TF (Twisted File #25, 27 mm) (Sybron Kerr, Orange, CA, USA) were cut into segments at 4 mm increment from the working tip. Regional specimens were measured for differential heat-flow over thermal cycling, generally with continuous heating or cooling (5 °C/min) and 5 min hold at set temperatures (start, finish temperatures): GTX: -55, 90 °C; K3: -55, 45 °C; TF: -55, 60 °C; using differential scanning calorimeter. This experiment demonstrated regional differences in A f along the axial length of GTX and K3 files. Similar variation was not obvious in the TF samples. A contributory effect of regional difference in strain-hardening due to grinding and machining during manufacturing is proposed.

  9. Disinfection of Streptococcus mutans Biofilm by a Non-Thermal Atmospheric Plasma Brush

    NASA Astrophysics Data System (ADS)

    Hong, Qing; Dong, Xiaoqing; Chen, Meng; Xu, Yuanxi; Sun, Hongmin; Hong, Liang; Yu, Qingsong

    2015-09-01

    This study investigated the argon plasma treatment effect on disinfecting dental biofilm by using an atmospheric pressure plasma brush. S. mutans biofilms were developed for 3 days on the surfaces of hydroxyapatite discs, which were used to simulate human tooth enamel. After plasma treatment, cell viability in the S. mutans biofilms was characterized by using MTT assay and confocal laser scanning microscopy (CLSM). Compared with the untreated control group, about 90% and 95% bacterial reduction in the biofilms was observed after 1 and 5 min plasma treatment, respectively. Scanning electron microscopy examination indicated severe cell damages occurred on the top surface of the plasma treated biofilms. CLSM showed that plasma treatment was effective as deep as 20 μm into the biofilms. When combined with 0.2% chlorhexidine digluconate solution, the plasma treatment became more effective and over 96% bacterial reduction was observed with 1 min plasma treatment. These results indicate that plasma treatment is effective and promising in dental biofilm disinfection.

  10. Safety of retained microcatheters: an evaluation of radiofrequency heating in endovascular microcatheters with nitinol, tungsten, and polyetheretherketone braiding at 1.5 T and 3 T

    PubMed Central

    Losey, Aaron D.; Lillaney, Prasheel; Martin, Alastair J.; Halbach, Van V.; Cooke, Daniel L.; Dowd, Christopher F.; Higashida, Randall T.; Saloner, David A.; Wilson, Mark W.; Saeed, Maythem; Hetts, Steven W.

    2013-01-01

    Background The use of ethylene-vinyl alcohol copolymer for liquid embolization of cranial vascular lesions has resulted in microcatheter fragments entrapped in patients following endovascular procedures. Undergoing subsequent diagnostic MRI examinations poses a safety concern due to the possibility of radiofrequency heating of the metallic braid incorporated into the microcatheter. Heating of nitinol, tungsten, and polyetheretherketone (PEEK) braided microcatheters was assessed and compared using a phantom model. Methods Microcatheters coupled with fluoroptic temperature probes were embedded in a polyacrylamide gel within a head and torso phantom. Experiments were performed at 1.5 T and 3 T, analyzing the effects of different catheter immersion lengths, specific absorption rate (SAR) levels, short clinical scans, long clinical scans, and microcatheter fragment lengths. Results The maximal increase in temperature for the nitinol braided microcatheter during a 15 min scan was 3.06°C using the T1 fast spin echo sequence at 1.5 T and 0.45°C using the balanced steady state free precession sequence at 3 T. The same scans for fragment lengths of 9, 18, 36, and 72 cm produced maximal temperature rises of 0.68, 0.80, 1.70, and 1.07°C at 1.5 T, respectively. The temperature changes at 3 T for these fragment lengths were 0.66, 0.83, 1.07, and 0.72°C, respectively. The tungsten and PEEK braided microcatheters did not demonstrate heating. Conclusions Substantial heating of nitinol braided microcatheters occurred and was a function of SAR level and geometric considerations. SAR and time limitations on MR scanning are proposed for patients with this microcatheter entrapped in their vasculature. In contrast, tungsten and PEEK braided microcatheters showed potential safe use in MRI. PMID:23685793

  11. 3-D sonography for diagnosis of disk dislocation of the temporomandibular joint compared with MRI.

    PubMed

    Landes, Constantin A; Goral, Wojciech A; Sader, Robert; Mack, Martin G

    2006-05-01

    This study determines the value of three-dimensional (3-D) sonography for the assessment of disk dislocation of the temporomandibular joint (TMJ). Sixty-eight patients (i.e.,136 TMJ) with clinical dysfunction were examined by 272 sonographic 3-D scans. An 8- to 12.5-MHz transducer, angulated by step-motor, was used after picking a volume box on 2-D scan; magnetic resonance imaging followed immediately. Every TMJ was scrutinized in closed- and open-mouth position for normal or dislocated disk position. Fifty-three patients had complete data sets, i.e., 106 TMJ, 212 examinations. Sonographic examination took 5 min, with 74% specificity (62% closed-mouth; 85% open-mouth); sensitivity 53% (62/43%); accuracy 70% (62/77%); positive predictive value 49% (57/41%); and negative predictive value 77% (67/86%). This study encourages more research on the diagnostic capacity of 3-D TMJ sonography, with the advantage of multidimensional joint visualization. Although fair in specificity and negative predictive value, sensitivity and accuracy may ameliorate with future higher-sound frequency, real-time 3-D viewing and automated image analysis.

  12. Whole-body muscle MRI in 20 patients suffering from late onset Pompe disease: Involvement patterns.

    PubMed

    Carlier, Robert-Yves; Laforet, Pascal; Wary, Claire; Mompoint, Dominique; Laloui, Kenza; Pellegrini, Nadine; Annane, Djillali; Carlier, Pierre G; Orlikowski, David

    2011-11-01

    To describe muscle involvement on whole-body MRI scans in adult patients at different stages of late-onset Pompe disease. Twenty patients aged 37 to 75 were examined. Five were bedridden and required ventilatory support. Axial and coronal T1 turbo-spin-echo sequences were performed on 1.5T or 3T systems. MRI was scored for 47 muscles using Mercuri's classification. Whole-body scans were obtained with a mean in-room time of 29 min. Muscle changes consisted of internal bright signals of fatty replacement without severe retraction of the muscles' corpus. Findings were consistent with previous descriptions of spine extensors and pelvic girdle, but also provided new information on recurrent muscle changes particularly in the tongue and subscapularis muscle. Moreover thigh involvement was more heterogeneous than previously described, in terms of distribution across muscles as well as with respect to the overall clinical presentation. Whole-body MRI provides a very evocative description of muscle involvement in Pompe disease in adults. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Laser Scanning Cytometry

    PubMed Central

    Pozarowski, Piotr; Holden, Elena; Darzynkiewicz, Zbigniew

    2013-01-01

    Summary The laser scanning cytometer (LSC) is the microscope-based cytofluorometer that offers a plethora of analytical capabilities. Multilaser-excited fluorescence emitted from individual cells is measured at several wavelength ranges, rapidly (up to 5000 cells/min), with high sensitivity and accuracy. The following applications of LSC are reviewed: (1) identification of cells that differ in degree of chromatin condensation (e.g., mitotic or apoptotic cells or lymphocytes vs granulocytes vs monocytes); (2) detection of translocation between cytoplasm vs nucleus or nucleoplasm vs nucleolus of regulatory molecules such as NF- κB, p53, or Bax; (3) semiautomatic scoring of micronuclei in mutagenicity assays; (4) analysis of fluorescence in situ hybridization; (5) enumeration and morphometry of nucleoli; (6) analysis of phenotype of progeny of individual cells in clonogenicity assay; (7) cell immunophenotyping; (8) visual examination, imaging, or sequential analysis of the cells measured earlier upon their relocation, using different probes; (9) in situ enzyme kinetics and other time-resolved processes; (10) analysis of tissue section architecture; (11) application for hypocellular samples (needle aspirate, spinal fluid, etc.); (12) other clinical applications. Advantages and limitations of LSC are discussed and compared with flow cytometry. PMID:16719355

  14. UV-Vis spectrophotometric studies of self-oxidation/dissociation of quaternary ammonium permanganates (QAP) - impact of solvent polarity

    NASA Astrophysics Data System (ADS)

    Bank, Suraj Prakash; Guru, Partha Sarathi; Dash, Sukalyan

    2015-05-01

    Self-oxidation/dissociation of some quaternary ammonium permanganates (QAPs), such as cetyltrimethylammonium permanganate (CTAP) and tetrabutylammonium permanganate (TBAP), have been studied spectrophotometrically in six different organic solvent media of different polarities wherein the compounds show good solubility and stability. The optical densities of the substrates at zero time (ODo) and first-order rate constants of dissociation (k1) have been determined from their successive scanning for 40 min. At comparable experimental conditions, absorption capabilities of the substrates are compared from the ODo values in various organic media; the stability of the solutions is compared from the successive scan spectra in those media. The ODo values and the k1 values have been plotted against some solvent parameters to understand their effects on the absorbance and reactivity of the QAPs. These data are also subjected to multiple regression analysis to explain the influence of various solvent parameters on the ion-pairing properties of the substrates, thus elucidating their effects on the process of self-oxidation/dissociation of the substrates.

  15. Evaluation of different sterilization and disinfection methods on commercially made preformed crowns.

    PubMed

    Yilmaz, Y; Guler, C

    2008-12-01

    The aim of this study was to evaluate the changes caused by different sterilization or disinfection methods on the vestibular surface of four commercially made preformed crowns using stereomicroscopy and scanning electron microscopy (SEM). Preformed crowns (NuSmile Primary Anterior Crown (NSC), Kinder Krowns (KK), Pedo Pearls (PP) and polycarbonate crowns (PC)) were sterilized and/or disinfected by one of the following techniques: no sterilization or disinfection (G1 control group); steam autoclaving at 134 degrees C (30 psi) for 4 min (G2); steam autoclaving at 134 degrees C (30 psi) for 12 min (G3); steam autoclaving at 121 degrees C (15 psi) for 30 min (G4); and ultrasonication in a bath containing 4% Lysetol AF for 5 min at room temperature (chemical disinfection) (G5). Scanning electron micrographs of the crowns were taken before and after their sterilization or disinfection. The changes on the vestibular surface were then scored for the presence or absence of crazing, contour alteration, fracturing, and vestibular surface changes. The data were analyzed statistically using the chi-square test. No changes were observed before and after sterilization or disinfection in the stereomicroscopic evaluation of the vestibular surface of the crowns. However, all methods in which steam autoclaving was used to sterilize the crowns caused significant (P < 0.05) crazing and contour alterations of the vestibular surface of the crowns when they were examined by SEM. Chemical disinfection using an aldehyde-free disinfectant is the preferred method of disinfection for crowns that have been used previously in other dental patients.

  16. Effects of Frequency Drift on the Quantification of Gamma-Aminobutyric Acid Using MEGA-PRESS

    PubMed Central

    Tsai, Shang-Yueh; Fang, Chun-Hao; Wu, Thai-Yu; Lin, Yi-Ru

    2016-01-01

    The MEGA-PRESS method is the most common method used to measure γ-aminobutyric acid (GABA) in the brain at 3T. It has been shown that the underestimation of the GABA signal due to B0 drift up to 1.22 Hz/min can be reduced by post-frequency alignment. In this study, we show that the underestimation of GABA can still occur even with post frequency alignment when the B0 drift is up to 3.93 Hz/min. The underestimation can be reduced by applying a frequency shift threshold. A total of 23 subjects were scanned twice to assess the short-term reproducibility, and 14 of them were scanned again after 2–8 weeks to evaluate the long-term reproducibility. A linear regression analysis of the quantified GABA versus the frequency shift showed a negative correlation (P < 0.01). Underestimation of the GABA signal was found. When a frequency shift threshold of 0.125 ppm (15.5 Hz or 1.79 Hz/min) was applied, the linear regression showed no statistically significant difference (P > 0.05). Therefore, a frequency shift threshold at 0.125 ppm (15.5 Hz) can be used to reduce underestimation during GABA quantification. For data with a B0 drift up to 3.93 Hz/min, the coefficients of variance of short-term and long-term reproducibility for the GABA quantification were less than 10% when the frequency threshold was applied. PMID:27079873

  17. SU-F-I-57: Evaluate and Optimize PET Acquisition Overlap in 18F-FDG Oncology Wholebody PET/CT: Can We Scan PET Faster?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, J; Natwa, M; Hall, NC

    Purpose: The longer patient has to remain on the table during PET imaging, the higher the likelihood of motion artifacts due to patient discomfort. This study was to investigate and optimize PET acquisition overlap in 18F-FDG oncology wholebody PET/CT to speed up PET acquisition and improve patient comfort. Methods: Wholebody 18F-FDG PET/CT of phantoms, 8 pre-clinical patients (beagles) and 5 clinical oncology patients were performed in 90s/bed on a time-of-flight Gemini TF 64 system. Imaging of phantoms and beagles was acquired with reduced PET overlaps (40%, 33%, 27%, 20%, 13% and no overlap) in addition to the system default (53%).more » In human studies, 1 or 2 reduced overlaps from the listed options were used to acquire PET/CT sweeps right after the default standard of care imaging. Image quality was blindly reviewed using visual scoring criteria and quantitative SUV assessment. NEMA PET sensitivity was performed under different overlaps. Results: All PET exams demonstrated no significant impact on the visual grades for overlaps >20%. Blinded reviews assigned the best visual scores to PET using overlaps 53%–27%. Reducing overlap to 27% for oncology patients (12-bed) saved an average of ∼40% acquisition time (11min) compared to using the default overlap (18min). No significant SUV variances were found when reducing overlap to half of default for cerebellum, lung, heart, aorta, liver, fat, muscle, bone marrow, thighs and target lesions (p>0.05), except expected variability in urinary system. Conclusion: This study demonstrated by combined phantom, pre-clinical and clinical PET/CT scans that PET acquisition overlap in axial of today’s systems can be reduced and optimized. It showed that a reduction of PET acquisition overlap to 27% (half of system default) can be implemented to reduce table time by ∼40% to improve patient comfort and minimize potential motion artifacts, without prominently degrading image quality or compromising PET quantification.« less

  18. Objective and subjective comparison of standard 2-D and fully 3-D reconstructed data on a PET/CT system.

    PubMed

    Strobel, Klaus; Rüdy, Matthias; Treyer, Valerie; Veit-Haibach, Patrick; Burger, Cyrill; Hany, Thomas F

    2007-07-01

    The relative advantage of fully 3-D versus 2-D mode for whole-body imaging is currently the focus of considerable expert debate. The nature of 3-D PET acquisition for FDG PET/CT theoretically allows a shorter scan time and improved efficiency of FDG use than in the standard 2-D acquisition. We therefore objectively and subjectively compared standard 2-D and fully 3-D reconstructed data for FDG PET/CT on a research PET/CT system. In a total of 36 patients (mean 58.9 years, range 17.3-78.9 years; 21 male, 15 female) referred for known or suspected malignancy, FDG PET/CT was performed using a research PET/CT system with advanced detector technology with improved sensitivity and spatial resolution. After 45 min uptake, a low-dose CT (40 mAs) from head to thigh was performed followed by 2-D PET (emission 3 min per field) and 3-D PET (emission 1.5 min per field) with both seven slices overlap to cover the identical anatomical region. Acquisition time was therefore 50% less (seven fields; 21 min vs. 10.5 min). PET data was acquired in a randomized fashion, so in 50% of the cases 2-D data was acquired first. CT data was used for attenuation correction. 2-D (OSEM) and 3-D PET images were iteratively reconstructed. Subjective analysis of 2-D and 3-D images was performed by two readers in a blinded, randomized fashion evaluating the following criteria: sharpness of organs (liver, chest wall/lung), overall image quality and detectability and dignity of each identified lesion. Objective analysis of PET data was investigated measuring maximum standard uptake value with lean body mass (SUV(max,LBM)) of identified lesions. On average, per patient, the SUV(max) was 7.86 (SD 7.79) for 2-D and 6.96 (SD 5.19) for 3-D. On a lesion basis, the average SUV(max) was 7.65 (SD 7.79) for 2-D and 6.75 (SD 5.89) for 3-D. The absolute difference on a paired t-test of SUV 3-D-2-D based on each measured lesion was significant with an average of -0.956 (P=0.002) and an average of -0.884 on a patient base (P<0.05). With 3-D the SUV(max) decreased by an average of 5.2% for each lesion, and an average of 6.0% for each patient. Subjective analysis showed fair inter-observer agreement regarding detectability (kappa=0.24 for 3-D; 0.36 for 3-D) and dignity (kappa=0.44 for 3-D and 0.4 for 2-D) of the lesions. There was no significant diagnostic difference between 3-D and 2-D. Only in one patient, a satellite liver metastasis of a colon cancer was missed in 3-D and detected only in 2-D. On average, the overall image quality for 3-D images was equal (in 24%) or inferior (in 76%) compared to 2-D. A possible major advantage of 3-D data acquisition is the faster patient throughput with a 50% reduction in scan time. The fully 3-D reconstruction technique has overcome the technical drawbacks of current 3-D imaging technique. In our limited number of patients there was no significant diagnostic difference between 2-D and fully 3-D.

  19. Microscopic observations of sonoporation mechanisms

    NASA Astrophysics Data System (ADS)

    Zeghimi, Aya; Escoffre, Jean-Michel; Bouakaz, Ayache

    2017-03-01

    Background Sonoporation promises a local gene/drug delivery with a high therapeutic efficacy and low toxicity level. However, the mechanisms orchestrating the molecules uptake are still unclear. Here, we investigate the effects of sonoporation on the plasma membrane of U-87 MG cells, either immediately or at different times post-sonoporation, using electron microscopy, and also the implication of cytoskeleton during the sonoporation process. Methods In our set-up, the U-87 MG cells were seeded on 18 mm diameter cover slips, placed in 24-well plates. The acoustic exposure conditions consisted of ultrasound pulses at 1 MHz, 1W/cm2 with duty cycle of 20% for 60 seconds. BR14® microbubbles were added to the cell medium before sonoporation at a microbubble/cell ratio of 5. These acoustic parameters were obtained as a result of a prior optimization experiments. Membrane permeabilization after sonoporation was assessed using SYTOX® Green dye (1 µM), as a model drug which does not cross the membrane of normal cells. The cell mortality was measured with propidium iodide staining. The alterations, on the plasma membrane, after sonoporation were monitored by scanning electron microscopy (SEM). The cell samples were processed immediately (0 min) and every 5 min up to 60 min post-sonoporation and coated by platinum sputtering (5 nm). For immunofluorescence experiments, the cells were fixed with 4% paraformaldehyde, and then incubated with TRITC-labeled Phalloidin, used to stain the actin cytoskeleton. Tubulin antibody Alexa Fluor® 555 conjugate was used to label the microtubules. Results Our results showed that immediately after ultrasound and microbubble exposure, dark and spherical structures appear on the plasma membrane. These structures have a diameter ranging from few nanometers to 160 nm. These structures are transient, since 15 min post-sonoporation, almost half of these structures disappeared. The decrease in the number of permeant structures is accentuated over time to be fully resorbed 60 min post-sonoporation, consequently the cells still metabolically active. Moreover, flow cytometry results show a positive correlation between membrane permeabilization and the number of these electron dense structures. Indeed, 60% of SYTOX® Green incorporation is achieved immediately after sonoporation, to decay over time and therefore as a function of the presence of these permeant structures on the cell membrane. These structures are named here "permeation structures". To define the nature of the TPS structures the cells were treated with Genistein, an inhibitor of caveolae-mediated endocytosis. Scanning Electron microscopy images showed a significant diminution of the number of TPS for cells incubated with Genistein, suggesting that a large part of these structures are caveolae still open. Moreover, immunofluorescence analysis showed a depolymerization of actin and tubulin cytoskeleton, immediately after sonoporation. This depolymerization is accompanied with a massive uptake of SYTOX® Green, while the use of cytochalasin D and nocodazole (inhibitors of actin and tubulin polymerization) induced a decrease in the percentage of SYTOX® Green incorporation. Conclusion In conclusion, our findings reveal the reversibility of sonoporation effects on the cell membrane, and show that the caveolae-mediated endocytosis is a dominant pathway involved in the sonoporation process of U-87 MG cells, with a probable involvement of other endocytic and non-endocytic pathways. Otherwise, the study of sonoporation on cytoskeleton gives evidence on the involvement of endocytosis during the sonoporation process (entry and transport of molecules).

  20. SU-G-IeP4-07: Feasibility of Low Dose 18FDG PET in Pediatric Oncology Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, J; Binzel, K; Hall, NC

    Purpose: To evaluate and demonstrate the feasibility of low dose FDG PET in pediatric oncology patients using virtual dose reduction as well as true patients PET/CT scans. Methods: Wholebody 18F-FDG PET/CT of 39 clinical pediatric patients (0.16±0.06MBq/kg) were scanned on a Gemini TF 64 system at 75±5 min post FDG injection using 3min/bed. Based on the 180s/bed listmode PET data, subsets of total counts in 120s, 90s, 60s, 30s and 15s per bed position were extracted for PET reconstruction to simulate lower dose PET at 2/3th, 1/2th, 1/3th, 1/6th and 1/12th dose levels. PET/CT scans of Jaszczak PET phantom withmore » 6 hot hollow spheres varying with sizes and contrast ratios were performed (real PET versus simulated PET) to validate the methodology of virtual dose PET simulation. Region of interests (ROIs) were placed on lesions and normal anatomical tissues with quantitative and qualitative assessment performed. Significant lower FDG dose PET/CT of 5 research adolescents were scanned to validate the proposal and low dose PET feasibility. Results: Although all lesions are visible on the 1/12th dose PET, overall PET image quality appears to be influenced in a multi-factorial way. 30%–60% dose reduction from current standard of care FDG PET is recommended to maintain equivalent quality and PET quantification. An optimized BMI-based FDG administration is recommended (from 1.1±0.5 mCi for BMI < 18.5 to 4.8±1.5 mCi for BMI > 30). A linear lowest “Dose-BMI” relationship is given. SUVs from 1/12th to full dose PETs were identified as consistent (R2 = 1.08, 0.99, 1.01, 1.00 and 0.98). No significant variances of count density, SUV and SNR were found across certain dose ranges (p<0.01). Conclusion: Pediatric PET/CT can be performed using current time-of-flight systems at substantially lower PET doses (30–60%) than the standard of care PET/CT without compromising qualitative and quantitative image quality in clinical.« less

  1. A Next-generation Tissue Microarray (ngTMA) Protocol for Biomarker Studies

    PubMed Central

    Zlobec, Inti; Suter, Guido; Perren, Aurel; Lugli, Alessandro

    2014-01-01

    Biomarker research relies on tissue microarrays (TMA). TMAs are produced by repeated transfer of small tissue cores from a ‘donor’ block into a ‘recipient’ block and then used for a variety of biomarker applications. The construction of conventional TMAs is labor intensive, imprecise, and time-consuming. Here, a protocol using next-generation Tissue Microarrays (ngTMA) is outlined. ngTMA is based on TMA planning and design, digital pathology, and automated tissue microarraying. The protocol is illustrated using an example of 134 metastatic colorectal cancer patients. Histological, statistical and logistical aspects are considered, such as the tissue type, specific histological regions, and cell types for inclusion in the TMA, the number of tissue spots, sample size, statistical analysis, and number of TMA copies. Histological slides for each patient are scanned and uploaded onto a web-based digital platform. There, they are viewed and annotated (marked) using a 0.6-2.0 mm diameter tool, multiple times using various colors to distinguish tissue areas. Donor blocks and 12 ‘recipient’ blocks are loaded into the instrument. Digital slides are retrieved and matched to donor block images. Repeated arraying of annotated regions is automatically performed resulting in an ngTMA. In this example, six ngTMAs are planned containing six different tissue types/histological zones. Two copies of the ngTMAs are desired. Three to four slides for each patient are scanned; 3 scan runs are necessary and performed overnight. All slides are annotated; different colors are used to represent the different tissues/zones, namely tumor center, invasion front, tumor/stroma, lymph node metastases, liver metastases, and normal tissue. 17 annotations/case are made; time for annotation is 2-3 min/case. 12 ngTMAs are produced containing 4,556 spots. Arraying time is 15-20 hr. Due to its precision, flexibility and speed, ngTMA is a powerful tool to further improve the quality of TMAs used in clinical and translational research. PMID:25285857

  2. Processing Parameters Optimization for Material Deposition Efficiency in Laser Metal Deposited Titanium Alloy

    NASA Astrophysics Data System (ADS)

    Mahamood, Rasheedat M.; Akinlabi, Esther T.

    2016-03-01

    Ti6Al4V is an important Titanium alloy that is mostly used in many applications such as: aerospace, petrochemical and medicine. The excellent corrosion resistance property, the high strength to weight ratio and the retention of properties at high temperature makes them to be favoured in most applications. The high cost of Titanium and its alloys makes their use to be prohibitive in some applications. Ti6Al4V can be cladded on a less expensive material such as steel, thereby reducing cost and providing excellent properties. Laser Metal Deposition (LMD) process, an additive manufacturing process is capable of producing complex part directly from the 3-D CAD model of the part and it also has the capability of handling multiple materials. Processing parameters play an important role in LMD process and in order to achieve desired results at a minimum cost, then the processing parameters need to be properly controlled. This paper investigates the role of processing parameters: laser power, scanning speed, powder flow rate and gas flow rate, on the material utilization efficiency in laser metal deposited Ti6Al4V. A two-level full factorial design of experiment was used in this investigation, to be able to understand the processing parameters that are most significant as well as the interactions among these processing parameters. Four process parameters were used, each with upper and lower settings which results in a combination of sixteen experiments. The laser power settings used was 1.8 and 3 kW, the scanning speed was 0.05 and 0.1 m/s, the powder flow rate was 2 and 4 g/min and the gas flow rate was 2 and 4 l/min. The experiments were designed and analyzed using Design Expert 8 software. The software was used to generate the optimized process parameters which were found to be laser power of 3.2 kW, scanning speed of 0.06 m/s, powder flow rate of 2 g/min and gas flow rate of 3 l/min.

  3. SU-E-I-32: Benchmarking Head CT Doses: A Pooled Vs. Protocol Specific Analysis of Radiation Doses in Adult Head CT Examinations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fujii, K; UCLA School of Medicine, Los Angeles, CA; Bostani, M

    Purpose: The aim of this study was to collect CT dose index data from adult head exams to establish benchmarks based on either: (a) values pooled from all head exams or (b) values for specific protocols. One part of this was to investigate differences in scan frequency and CT dose index data for inpatients versus outpatients. Methods: We collected CT dose index data (CTDIvol) from adult head CT examinations performed at our medical facilities from Jan 1st to Dec 31th, 2014. Four of these scanners were used for inpatients, the other five were used for outpatients. All scanners used Tubemore » Current Modulation. We used X-ray dose management software to mine dose index data and evaluate CTDIvol for 15807 inpatients and 4263 outpatients undergoing Routine Brain, Sinus, Facial/Mandible, Temporal Bone, CTA Brain and CTA Brain-Neck protocols, and combined across all protocols. Results: For inpatients, Routine Brain series represented 84% of total scans performed. For outpatients, Sinus scans represented the largest fraction (36%). The CTDIvol (mean ± SD) across all head protocols was 39 ± 30 mGy (min-max: 3.3–540 mGy). The CTDIvol for Routine Brain was 51 ± 6.2 mGy (min-max: 36–84 mGy). The values for Sinus were 24 ± 3.2 mGy (min-max: 13–44 mGy) and for Facial/Mandible were 22 ± 4.3 mGy (min-max: 14–46 mGy). The mean CTDIvol for inpatients and outpatients was similar across protocols with one exception (CTA Brain-Neck). Conclusion: There is substantial dose variation when results from all protocols are pooled together; this is primarily a function of the differences in technical factors of the protocols themselves. When protocols are analyzed separately, there is much less variability. While analyzing pooled data affords some utility, reviewing protocols segregated by clinical indication provides greater opportunity for optimization and establishing useful benchmarks.« less

  4. Timelines in the management of adrenal crisis - targets, limits and reality.

    PubMed

    Hahner, Stefanie; Hemmelmann, Nina; Quinkler, Marcus; Beuschlein, Felix; Spinnler, Christina; Allolio, Bruno

    2015-04-01

    To evaluate current management timelines in adrenal crisis (AC) and to establish time targets and time limits for emergency treatment. Patients from a prospective study who had reported an AC (n = 46) were contacted and asked about management of their AC. A survey among 24 European endocrinologists collected expert recommendations concerning time targets and time limits for contact-arrival time of emergency health professionals and presentation of emergency card-glucocorticoid (GC) injection time. Median time targets and time limits regarded by experts as adequate for contact-arrival time were 45 and 90 min, respectively, and for card-injection time 15 and 30 min, respectively. Thirty-seven of 46 patients could be interviewed. All patients were equipped with an emergency card but only 23 (62%) with an emergency kit. Seven patients (19%) were trained in GC self-injection. The median time interval between contacting a health professional and arrival was 20 min (range 2-2880 min); ≤45 min: n = 32 (86%), <90 min: n = 34 (92%). The median time interval between arrival and administration of GC was 30 min (range 2-2400 min); ≤15 min: n = 17 (46%), ≤30 min: n = 20 (54%). While the time between contacting health professionals and their arrival was within the limits set by experts, initiation of GC administration was delayed in 46% of patients. Thus, improved management of AC needs to focus on shortening the presentation of card-injection time. Given the current reality in the management of AC, promotion of self-injection of GC (s.c. or i.m.) is warranted. © 2014 John Wiley & Sons Ltd.

  5. Introduction of an operating room information management system improved overall operating room efficiency.

    PubMed

    De Deyne, Cathy; Heylen, René

    2004-01-01

    Operating Room (OR) information systems should manage the OR time, assigned to every surgeon, thereby minimizing the sum of costs of unused OR time and minimizing the costs of elective cases performed outside normal allocated OR time (excess OR-time). The aim of this paper is to illustrate how the introduction of an OR information system influenced daily OR activity performance. Since January 2001, we introduced an OR information system with a visual, airport-like, screen as central part, displaying all scheduled OR activity linked in real-time activity with all OR theatres. For the aim of this paper, we compared all data of OR activity for elective abdominal surgery (EAS) for the first half of 2000 compared to the first half of 2001, after the introduction of our information system. In 2000, 764 elective cases were performed, compared to 815 cases in 2001. For both periods, the total OR time allocated to EAS for this 6 months period was 805 h. For 2000, the total duration of OR activity for EAS was 1044 h 50 min (implicating 239 h 50 min over-time), compared to 1127 h 35 min (implicating 322 h 35 min overtime) for 2001. For 2000, we recorded 147 h 20 min excess time (=exceeding the time limits of OR activity and inducing extra costs) and 46h45min unused OR time. For 2001, we recorded 123 h 04 min excess time and 35 h 21 min unused time. In conclusion, in 2001 we recorded an increase in total OR activity for elective abdominal surgery by 7% in number of procedures and by 8% in total duration. However, in 2001 we recorded a decrease in excess time by 16% (123 h 04 min vs 147 h 20 min), which was for a large part due to a 23% decrease in unused OR time in 2001 compared to 2000 (35 h 21min vs 46 h 45 min). Therefore, the introduction of an OR information system, with a real-time visual display of ongoing OR activity, resulted in a increased performance of OR activity, with more OR procedures performed despite less excess time and less extra costs.

  6. Monitoring early response to chemoradiotherapy with 18F-FMISO dynamic PET in head and neck cancer.

    PubMed

    Grkovski, Milan; Lee, Nancy Y; Schöder, Heiko; Carlin, Sean D; Beattie, Bradley J; Riaz, Nadeem; Leeman, Jonathan E; O'Donoghue, Joseph A; Humm, John L

    2017-09-01

    There is growing recognition that biologic features of the tumor microenvironment affect the response to cancer therapies and the outcome of cancer patients. In head and neck cancer (HNC) one such feature is hypoxia. We investigated the utility of 18 F-fluoromisonidazole (FMISO) dynamic positron emission tomography (dPET) for monitoring the early microenvironmental response to chemoradiotherapy in HNC. Seventy-two HNC patients underwent FMISO dPET scans in a customized immobilization mask (0-30 min dynamic acquisition, followed by 10 min static acquisitions starting at ∼95 min and ∼160 min post-injection) at baseline and early into treatment where patients have already received one cycle of chemotherapy and anywhere from five to ten fractions of 2 Gy per fraction radiation therapy. Voxelwise pharmacokinetic modeling was conducted using an irreversible one-plasma two-tissue compartment model to calculate surrogate biomarkers of tumor hypoxia (k 3 and Tumor-to-Blood Ratio (TBR)), perfusion (K 1 ) and FMISO distribution volume (DV). Additionally, Tumor-to-Muscle Ratios (TMR) were derived by visual inspection by an experienced nuclear medicine physician, with TMR > 1.2 defining hypoxia. One hundred and thirty-five lesions in total were analyzed. TBR, k 3 and DV decreased on early response scans, while no significant change was observed for K 1 . The k 3 -TBR correlation decreased substantially from baseline scans (Pearson's r = 0.72 and 0.76 for mean intratumor and pooled voxelwise values, respectively) to early response scans (Pearson's r = 0.39 and 0.40, respectively). Both concordant and discordant examples of changes in intratumor k 3 and TBR were identified; the latter partially mediated by the change in DV. In 13 normoxic patients according to visual analysis (all having lesions with TMR = 1.2), subvolumes were identified where k 3 indicated the presence of hypoxia. Pharmacokinetic modeling of FMISO dynamic PET reveals a more detailed characterization of the tumor microenvironment and assessment of response to chemoradiotherapy in HNC patients than a single static image does. In a clinical trial where absence of hypoxia in primary tumor and lymph nodes would lead to de-escalation of therapy, the observed disagreement between visual analysis and pharmacokinetic modeling results would have affected patient management in <20% cases. While simple static PET imaging is easily implemented for clinical trials, the clinical applicability of pharmacokinetic modeling remains to be investigated.

  7. Fireproofing and heat insulating performance improvement of EG/ATH modified intumescent flame retardant coating treated under Co-60 radiation

    NASA Astrophysics Data System (ADS)

    Zhang, Yuehong; Luan, Weiling; Jiang, Tao

    2017-12-01

    New intumescent flame retardant (IFR) coatings with different fire retardants were prepared in this paper. Expandable graphite (EG) and Aluminium hydroxide (ATH) were respectively added into the conventional IFR coating system, which included ammonium polyphosphate (APP) / pentaerythritol (PER) / melamine (MEL). The fireproofing time and heat insulating properties of the additives acted as fire retardants were investigated via thermogravimetry analysis (TGA) and fire resistance test of homemade big panel test. The morphology of the char layer structure was achieved by scanning electron microscopy (SEM). The highlight of the paper was that the coating samples were pretreated under Co-60 radiation. The influence of radiation on the fire resistance time and char layer height was investigated. The results showed that the prepared IFR coatings can be used in Co-60 radiation for more than 90 min when encountering fire. It would be a reference for radiation shielding in nuclear environment.

  8. High-speed femtosecond pump-probe spectroscopy with a smart pixel detector array.

    PubMed

    Bourquin, S; Prasankumar, R P; Kärtner, F X; Fujimoto, J G; Lasser, T; Salathé, R P

    2003-09-01

    A new femtosecond pump-probe spectroscopy technique is demonstrated that permits the high-speed, parallel acquisition of pump-probe measurements at multiple wavelengths. This is made possible by use of a novel, two-dimensional smart pixel detector array that performs amplitude demodulation in real time on each pixel. This detector array can not only achieve sensitivities comparable with lock-in amplification but also simultaneously performs demodulation of probe transmission signals at multiple wavelengths, thus permitting rapid time- and wavelength-resolved femtosecond pump-probe spectroscopy. Measurements on a thin sample of bulk GaAs are performed across 58 simultaneous wavelengths. Differential probe transmission changes as small as approximately 2 x 10(-4) can be measured over a 5-ps delay scan in only approximately 3 min. This technology can be applied to a wide range of pump-probe measurements in condensed matter, chemistry, and biology.

  9. Optical constants, dispersion energy parameters and dielectric properties of ultra-smooth nanocrystalline BiVO4 thin films prepared by rf-magnetron sputtering

    NASA Astrophysics Data System (ADS)

    Sarkar, S.; Das, N. S.; Chattopadhyay, K. K.

    2014-07-01

    BiVO4 thin films have been prepared through radio frequency (rf) magnetron sputtering of a pre-fabricated BiVO4 target on ITO coated glass (ITO-glass) substrate and bare glass substrates. BiVO4 target material was prepared through solid-state reaction method by heating Bi2O3 and V2O5 mixture at 800 °C for 8 h. The films were characterized by X-ray diffraction, UV-Vis spectroscopy, LCR meter, field emission scanning electron microscopy, transmission electron microscopy and atomic force microscopy. BiVO4 thin films deposited on the ITO-glass substrate are much smoother compared to the thin films prepared on bare glass substrate. The rms surface roughness calculated from the AFM images comes out to be 0.74 nm and 4.2 nm for the films deposited on the ITO-glass substrate and bare glass substrate for the deposition time 150 min respectively. Optical constants and energy dispersion parameters of these extra-smooth BiVO4 thin films have been investigated in detail. Dielectric properties of the BiVO4 thin films on ITO-glass substrate were also investigated. The frequency dependence of dielectric constant of the BiVO4 thin films has been measured in the frequency range from 20 Hz to 2 MHz. It was found that the dielectric constant increased from 145 to 343 at 20 Hz as the film thickness increased from 90 nm to 145 nm (deposition time increased from 60 min to 150 min). It shows higher dielectric constant compared to the literature value of BiVO4.

  10. Metal-organic framework MIL-101 as sorbent based on double-pumps controlled on-line solid-phase extraction coupled with high-performance liquid chromatography for the determination of flavonoids in environmental water samples.

    PubMed

    Liu, Yue; Hu, Jia; Li, Yan; Li, Xiao-Shuang; Wang, Zhong-Liang

    2016-10-01

    A novel method with high sensitivity for the rapid determination of chrysin, apigenin and luteolin in environment water samples was developed by double-pumps controlled on-line solid-phase extraction (SPE) coupled with high-performance liquid chromatography (HPLC). In the developed technique, metal organic framework MIL-101 was synthesized and applied as a sorbent for SPE. The as-synthesized MIL-101 was characterized by scanning electron microscope, X-ray diffraction spectrometry, thermal gravimetric analysis and micropore physisorption analysis. The MIL-101 behaved as a fast kinetics in the adsorption of chrysin, apigenin and luteolin. On-line SPE of chrysin, apigenin and luteolin was processed by loading a sample solution at a flow rate of 1.0 mL/min for 10 min. The extracted analytes were subsequently eluted into a ZORBAX Bonus-RP analytical column (25 cm long × 4.6 mm i.d.) for HPLC separation under isocratic condition with a mobile phase (MeOH: ACN: 0.02 M H 3 PO 4 = 35:35:30) at a flow rate of 1.0 mL/min. Experimental conditions, including ionic strength, sample pH, sample loading rates, sample loading time and desorption analytes time, were further optimized to obtain efficient preconcentration and high-precision determination of the analytes mentioned above. The method achieved the merits of simplicity, rapidity, sensitivity, wide linear range and high sample throughput. The possible mechanism for the adsorption of flavonoids on MIL-101 was proposed. The developed method has been applied to determine trace chrysin, apigenin and luteolin in a variety of environmental water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Determination of species-difference in microsomal metabolism of amitriptyline using a predictive MRM-IDA-EPI method.

    PubMed

    Lee, Ji-Yoon; Lee, Sang Yoon; Lee, KiHo; Oh, Soo Jin; Kim, Sang Kyum

    2015-03-05

    We investigated to compare species differences in amitriptyline (AMI) metabolism among mouse, rat, dog, and human liver microsomes. We developed a method for simultaneous determination of metabolic stability and metabolite profiling using predictive multiple reaction monitoring information-dependent acquisition-enhanced product ion (MRM-IDA-EPI) scanning. In the cofactor-dependent microsomal metabolism study, AMI was metabolized more rapidly in rat and human liver microsomes incubated with NADPH than UDPGA. AMI incubated with NADPH+UDPGA in rat, dog, or mouse liver microsomes disappeared rapidly with a half-life of 3.5, 8.4, or 9.2 min, respectively, but slowly in human liver microsomes with a half-life of 96 min. In total, 9, 10, 11, and 6 putative metabolites of AMI were detected in mouse, rat, dog, and human liver microsomes, respectively, based on mass spectrometric analyses. Kinetic analysis of metabolites in liver microsomes from each species over 120 min showed common metabolic routes of AMI, such as N-demethylation, hydroxylation, and glucuronidation, and subtle interspecies differences in AMI metabolism. The main metabolic routes in mouse, rat, dog, and human liver microsomes were hydroxylation followed by glucuronide conjugation, methyl hydroxylation, and N-demethylation, respectively. The MRM-IDA-EPI method can provide quantitative and qualitative information about metabolic stability and metabolite profiling simultaneously. Moreover, time course analysis of metabolites can not only eliminate false identification of metabolites, but also provide a rationale for proposed metabolic pathways. The MRM-IDA-EPI method combined with time course analysis of metabolites is useful for investigating drug metabolism at the early drug discovery stage. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. A sensitive analysis method for 7 diterpenoids in rat plasma by liquid chromatography-electrospray ionization mass spectrometry and its application to pharmacokinetic study of Isodon serra extract.

    PubMed

    Du, Yingfeng; Liu, Pengwei; Zhu, Hong; Shi, Xiaowei; Zhao, Chengcheng; Wang, Na; Zhang, Lantong

    2011-10-28

    A simple and sensitive LC-MS/MS method has been developed and validated for the identification and quantification of epinodosin, epinodosinol, nodosin, oridonin, lasiokariurinol, lasiokaurin and rabdoternin A in rat plasma using sulfamethoxazole as the internal standard. The plasma sample pre-treatment consisted of a liquid-liquid extraction. Chromatographic separation was achieved on a C18 column with linear gradient elution using water and methanol, which were both acidified with 0.1% formic acid, at a flow rate of 0.7 mL/min. A tandem mass spectrometric detection was conducted using multiple reaction monitoring (MRM) via an electrospray ionization (ESI) source. A novel multi-determination-periods program was executed to achieve a higher sensitivity by setting five scanning periods. The method presented here utilizes a novel determination strategy, enabling the application of positive and negative ESI-MS in a single run. The optimized mass transition ion-pairs (m/z) for quantitation were 361.2/287.1 for epinodosin, 382.3/347.3 for epinodosinol, 363.3/281.2 for nodosin, 365.3/347.3 for oridonin, 407.3/329.1 for lasiokariurinol, 405.2/59.0 for lasiokaurin, 363.2/283.1 for rabdoternin A and 254.1/156.0 for IS. The total run time was 20.50 min (including 5 min equilibration time) between injections. The specificity, linearity, accuracy, precision, recovery, matrix effect and several validation results demonstrate that this method is sensitive, specific and reliable. The proposed method was further applied to investigate the pharmacokinetics of all analytes after a single oral administration of Isodon serra extract to rats. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Prediction of time-integrated activity coefficients in PRRT using simulated dynamic PET and a pharmacokinetic model.

    PubMed

    Hardiansyah, Deni; Attarwala, Ali Asgar; Kletting, Peter; Mottaghy, Felix M; Glatting, Gerhard

    2017-10-01

    To investigate the accuracy of predicted time-integrated activity coefficients (TIACs) in peptide-receptor radionuclide therapy (PRRT) using simulated dynamic PET data and a physiologically based pharmacokinetic (PBPK) model. PBPK parameters were estimated using biokinetic data of 15 patients after injection of (152±15)MBq of 111 In-DTPAOC (total peptide amount (5.78±0.25)nmol). True mathematical phantoms of patients (MPPs) were the PBPK model with the estimated parameters. Dynamic PET measurements were simulated as being done after bolus injection of 150MBq 68 Ga-DOTATATE using the true MPPs. Dynamic PET scans around 35min p.i. (P 1 ), 4h p.i. (P 2 ) and the combination of P 1 and P 2 (P 3 ) were simulated. Each measurement was simulated with four frames of 5min each and 2 bed positions. PBPK parameters were fitted to the PET data to derive the PET-predicted MPPs. Therapy was simulated assuming an infusion of 5.1GBq of 90 Y-DOTATATE over 30min in both true and PET-predicted MPPs. TIACs of simulated therapy were calculated, true MPPs (true TIACs) and predicted MPPs (predicted TIACs) followed by the calculation of variabilities v. For P 1 and P 2 the population variabilities of kidneys, liver and spleen were acceptable (v<10%). For the tumours and the remainders, the values were large (up to 25%). For P 3 , population variabilities for all organs including the remainder further improved, except that of the tumour (v>10%). Treatment planning of PRRT based on dynamic PET data seems possible for the kidneys, liver and spleen using a PBPK model and patient specific information. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  14. Effect of Metal Ion Etching on the Tribological, Mechanical and Microstructural Properties of TiN-COATED d2 Tool Steel Using Cae Pvd Technique

    NASA Astrophysics Data System (ADS)

    Ali, Mubarak; Hamzah, Esah Binti; Hj. Mohd Toff, Mohd Radzi

    A study has been made on TiN coatings deposited on D2 tool steel substrates by using commercially available cathodic arc evaporation, physical vapor deposition technique. The goal of this work is to determine the usefulness of TiN coatings in order to improve the micro-Vickers hardness, coefficient of friction and surface roughness of TiN coating deposited on tool steel, which is vastly use in tool industry for various applications. A pin-on-disc test was carried out to study the coefficient of friction versus sliding distance of TiN coating at various ion etching rates. The tribo-test showed that the minimum value recorded for friction coefficient was 0.386 and 0.472 with standard deviation of 0.056 and 0.036 for the coatings deposited at zero and 16 min ion etching. The differences in friction coefficient and surface roughness was mainly associated with the macrodroplets, which was produced during etching stage. The coating deposited for 16 min metal ion etching showed the maximum hardness, i.e., about five times higher than uncoated one and 1.24 times to the coating deposited at zero ion etching. After friction test, the wear track was observed by using field emission scanning electron microscope. The coating deposited for zero ion etching showed small amounts of macrodroplets as compared to the coating deposited for 16 min ion etching. The elemental composition on the wear scar were investigated by means of energy dispersive X-ray, indicate no further TiN coating on wear track. A considerable improvement in TiN coatings was recorded as a function of various ion etching rates.

  15. Meditative music listening to reduce state anxiety in patients during the uptake phase before positron emission tomography (PET) scans

    PubMed Central

    Lee, Wen-Li; Liu, Shu-Hsin; Chang, Shu-Min

    2017-01-01

    Objective: This study examines the effects of listening to meditative music on state anxiety and heart rate variability (HRV) of patients during the uptake phase before positron emission tomography (PET) scans. Methods: A two-group randomized experimental design was used. Eligible patients were randomly assigned to either the experimental or control group. All patients received baseline assessments of state anxiety using Spielberger State-Trait Anxiety Inventory (STAI-S) and HRV before receiving an intravenous injection of radiopharmaceutical fluorine-18 fludeoxyglucose in the uptake room. The experimental group (n = 35) listened individually to 30 min of meditative music, integrating Chinese “Chi” and western frequency resonation in the uptake room. The control group (n = 37) lay on bed quietly for 40 min in the uptake room without music. All patients were assessed for their anxiety level and HRV again, before receiving PET scanning as post-test. Results: The results indicated that patients in the experimental group showed a significant reduction in state anxiety and heart rate, and increase on high frequency norm of HRV (p < 0.001). There was a statistically significant reduction on anxiety level (p < 0.001), heart rate (p < 0.001) and high frequency norm (p = 0.001) in the experimental group compared with those of the control group. Conclusion: Listening to meditative music as a non-invasive and cost-effective strategy can help maximize efforts to promote comfort and relaxation for patients awaiting stressful procedures, such as PET scans. Meditative music can be effective in alleviating state anxiety of patients during the uptake phase before PET scans. Advances in knowledge: The study provides scientific evidence of the effects of listening to meditative music for reducing state anxiety in patients during the uptake phase before PET scans. It may have the potential to lower the risk of unwanted false-positive fluorine-18 fludeoxyglucose uptake in normal organs and to further improve image quality and image interpretation. Listening to meditative music is a safe and inexpensive intervention which can be incorporated into routine procedures to reduce anxiety of patients undergoing PET scans. PMID:27897034

  16. Meditative music listening to reduce state anxiety in patients during the uptake phase before positron emission tomography (PET) scans.

    PubMed

    Lee, Wen-Li; Sung, Huei-Chuan; Liu, Shu-Hsin; Chang, Shu-Min

    2017-02-01

    This study examines the effects of listening to meditative music on state anxiety and heart rate variability (HRV) of patients during the uptake phase before positron emission tomography (PET) scans. A two-group randomized experimental design was used. Eligible patients were randomly assigned to either the experimental or control group. All patients received baseline assessments of state anxiety using Spielberger State-Trait Anxiety Inventory (STAI-S) and HRV before receiving an intravenous injection of radiopharmaceutical fluorine-18 fludeoxyglucose in the uptake room. The experimental group (n = 35) listened individually to 30 min of meditative music, integrating Chinese "Chi" and western frequency resonation in the uptake room. The control group (n = 37) lay on bed quietly for 40 min in the uptake room without music. All patients were assessed for their anxiety level and HRV again, before receiving PET scanning as post-test. The results indicated that patients in the experimental group showed a significant reduction in state anxiety and heart rate, and increase on high frequency norm of HRV (p < 0.001). There was a statistically significant reduction on anxiety level (p < 0.001), heart rate (p < 0.001) and high frequency norm (p = 0.001) in the experimental group compared with those of the control group. Listening to meditative music as a non-invasive and cost-effective strategy can help maximize efforts to promote comfort and relaxation for patients awaiting stressful procedures, such as PET scans. Meditative music can be effective in alleviating state anxiety of patients during the uptake phase before PET scans. Advances in knowledge: The study provides scientific evidence of the effects of listening to meditative music for reducing state anxiety in patients during the uptake phase before PET scans. It may have the potential to lower the risk of unwanted false-positive fluorine-18 fludeoxyglucose uptake in normal organs and to further improve image quality and image interpretation. Listening to meditative music is a safe and inexpensive intervention which can be incorporated into routine procedures to reduce anxiety of patients undergoing PET scans.

  17. Small intestinal bacterial overgrowth as an uncommon cause of false positive lactose hydrogen breath test among patients with diarrhea-predominant irritable bowel syndrome in Asia.

    PubMed

    Wang, Yilin; Xiong, Lishou; Gong, Xiaorong; Li, Weimin; Zhang, Xiangsong; Chen, Minhu

    2015-06-01

    It has been reported that small intestinal bacterial overgrowth (SIBO) may lead to false positive diagnoses of lactose malabsorption (LM) in irritable bowel syndrome patients. The aim of this study was to determine the influence of SIBO on lactose hydrogen breath test (HBT) results in these patients. Diarrhea-predominant irritable bowel syndrome patients with abnormal lactose HBTs ingested a test meal containing (99m) Tc and lactose. The location of the test meal and the breath levels of hydrogen were recorded simultaneously by scintigraphic scanning and lactose HBT, respectively. The increase in hydrogen concentration was not considered to be caused by SIBO if ≥ 10% of (99m) Tc accumulated in the cecal region at the time or before of abnormal lactose HBT. LM was present in 84% (31/37) of irritable bowel syndrome patients. Twenty of these patients agreed to measurement of oro-cecal transit time. Only three patients (15%) with abnormal lactose HBT might have had SIBO. The median oro-cecal transit time between LM and lactose intolerance patients were 75 min and 45 min, respectively (Z=2.545, P=0.011). Most of irritable bowel syndrome patients with an abnormal lactose HBT had LM. SIBO had little impact on the interpretation of lactose HBTs. The patients with lactose intolerance had faster small intestinal transit than LM patients. © 2014 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  18. The Impact of Amorphisation and Spheronization Techniques on the Improved in Vitro & in Vivo Performance of Glimepiride Tablets

    PubMed Central

    Makar, Rana Refaat; Latif, Randa; Hosni, Ehab Ahmed; El Gazayerly, Omaima Naim

    2017-01-01

    Purpose: Triple solid dispersion adsorbates (TSDads) and spherical agglomerates (SA) present new techniques that extensively enhance dissolution of poorly soluble drugs. The aim of the present study is to hasten the onset of hypoglycemic effect of glimepiride through enhancing its rate of release from tablet formulation prepared from either technique. Methods: Drug release from TSDads or SA tablets with different added excipients was explored. Scanning electron microscopy (SEM) and effect of compression on dissolution were illustrated. Pharmacodynamic evaluation was performed on optimized tablets. Results: TSDads & SA tablets with Cross Povidone showed least disintegration times of 1.48 and 0.5 min. respectively. Kinetics of drug release recorded least half-lives (54.13 and 59.83min for both techniques respectively). Cross section in tablets displayed an organized interconnected matrix under SEM, accounting for the rapid access of dissolution media to the tablet core. Components of tablets filled into capsules showed a similar release profile to that of tablets after compression as indicated by similarity factor. The onset time of maximum reduction in blood glucose in male albino rabbits was hastened to 2h instead of 3h for commercial tablets. Conclusion: After optimization of tablet excipients that interacted differently with respect to their effect on drug release, we could conclude that both amorphisation and spheronization were equally successful in promoting in vitro dissolution enhancement as well as providing a more rapid onset time for drug action in vivo. PMID:29399545

  19. 25G compared with 20G vitrectomy under Resight non-contact wide-angle lenses for Terson syndrome.

    PubMed

    Mao, Xinbang; You, Zhipeng

    2017-08-01

    The aim of the present study was to compare the effectiveness of 25G vitrectomy to standard 20G vitrectomy for treatment of Terson syndrome under Resight non-contact wide-angle lenses. This was a case-control study of 20 patients with Terson syndrome (study group) that underwent 25G vitrectomy under Resight non-contact wide-angle lenses, with those of 20 matched patients that underwent 20G vitrectomy (control group). Medical records were reviewed from between July 2011 and October 2013. Data included results of the Early Treatment Diabetic Retinopathy Study examination, ophthalmology B-scan ultrasonography and fundus photography. The mean age, follow-up time, the preoperative visual acuity of LogMAR and the preoperative intraocular pressure (IOP) were all comparable in the two groups (all P>0.05). There were statistically significant differences in postoperative visual acuity of LogMAR compared with preoperative visual acuity (P<0.001) in both groups, but no difference between the groups (P=0.845). However, the operative times (13.5 min in study group vs. 42 min in control group) and post-operative IOP at day 1 (13.5 vs. 20 mmHg) were significantly reduced in the study group compared to the control group (P<0.001). Therefore, the present findings suggest that 25G Vitrectomy for Terson syndrome under Resight non-contact wide-angle lenses can achieve a significantly shorter operative time and lower post-operative IOP compared with 20G Vitrectomy.

  20. Fast fabrication of long TiO2 nanotube array with high photoelectrochemical property on flexible stainless steel.

    PubMed

    Tao, Jie; Wu, Tao; Gao, Peng

    2012-03-01

    Oriented highly ordered long TiO2 nanotube array films with nanopore structure and high photoelectrochemical property were fabricated on flexible stainless steel substrate (50 microm) by anodization treatment of titanium thin films in a short time. The samples were characterized by means of field emission scanning electron microscopy (FESEM), X-ray diffraction (XRD) and photoelectrochemical methods, respectively. The results showed that Ti films deposited at the condition of 0.7 Pa Ar pressure and 96 W sputtering power at room temperature was uniform and dense with good homogeneity and high crystallinity. The voltage and the anodization time both played significant roles in the formation of TiO2 nanopore-nanotube array film. The optimal voltage was 60 V and the anodization time is less than 30 min by anodizing Ti films in ethylene glycerol containing 0.5% (w) NH4F and 3% (w) H2O. The growth rate of TiO2 nanotube array was as high as 340 nm/min. Moreover, the photocurrent-potential curves, photocurrent response curves and electrochemical impedance spectra results indicated that the TiO2 nanotube array film with the nanoporous structure exhibited a better photo-response ability and photoelectrochemical performance than the ordinary TiO2 nanotube array film. The reason is that the nanoporous structure on the surface of the nanotube array can separate the photo electron-hole pairs more efficiently and completely than the tubular structure.