Willemse, Elias J; Joubert, Johan W
2016-09-01
In this article we present benchmark datasets for the Mixed Capacitated Arc Routing Problem under Time restrictions with Intermediate Facilities (MCARPTIF). The problem is a generalisation of the Capacitated Arc Routing Problem (CARP), and closely represents waste collection routing. Four different test sets are presented, each consisting of multiple instance files, and which can be used to benchmark different solution approaches for the MCARPTIF. An in-depth description of the datasets can be found in "Constructive heuristics for the Mixed Capacity Arc Routing Problem under Time Restrictions with Intermediate Facilities" (Willemseand Joubert, 2016) [2] and "Splitting procedures for the Mixed Capacitated Arc Routing Problem under Time restrictions with Intermediate Facilities" (Willemseand Joubert, in press) [4]. The datasets are publicly available from "Library of benchmark test sets for variants of the Capacitated Arc Routing Problem under Time restrictions with Intermediate Facilities" (Willemse and Joubert, 2016) [3].
Recent Enhancements to the National Transonic Facility (Mixed Mode Operations)
NASA Technical Reports Server (NTRS)
Kilgore, W. Allen; Chan, David; Balakrishna, S.; Wahls, Richard A.
2006-01-01
The U.S. National Transonic Facility continues to make enhancements to provide quality data in a safe, efficient and cost effective method for aerodynamic ground testing. Recent enhancements discussed in this paper include the development of a Mixed-mode of operations that combine Air-mode operations with Nitrogen-mode operations. This implementation and operational results of this new Mixed-mode expands the ambient temperature transonic region of testing beyond the Air-mode limitations at a significantly reduced cost over Nitrogen Mode operation.
DOT National Transportation Integrated Search
2012-11-01
The acceptance testing of Hot Mix Asphalt (HMA) conducted at the HMA production facility is an : important portion of the overall acceptance process used by the Connecticut Department of : Transportation (ConnDOT) for paving projects. In 2004, ConnDO...
High-speed flight propulsion systems. Progress in Astronautics and Aeronautics. Vol. 137
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murthy, S.N.B.; Curran, E.T.
1991-01-01
Various papers on high-speed flight propulsion systems are presented. The topics addressed are: propulsion systems from takeoff to high-speed flight, propulsion system performance and integration for high Mach air-breathing flight, energy analysis of high-speed flight systems, waves and thermodynamics in high Mach number propulsive ducts, turbulent free shear layer mixing and combustion, turbulent mixing in supersonic combustion systems, mixing and mixing enhancement in supersonic reacting flowfields, study of combustion and heat-exchange processes in high-enthalpy short-duration facilities, and facility requirements for hypersonic propulsion system testing.
21 CFR 58.47 - Facilities for handling test and control articles.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Facilities for handling test and control articles... for handling test and control articles. (a) As necessary to prevent contamination or mixups, there shall be separate areas for: (1) Receipt and storage of the test and control articles. (2) Mixing of the...
21 CFR 58.47 - Facilities for handling test and control articles.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Facilities for handling test and control articles... for handling test and control articles. (a) As necessary to prevent contamination or mixups, there shall be separate areas for: (1) Receipt and storage of the test and control articles. (2) Mixing of the...
21 CFR 58.47 - Facilities for handling test and control articles.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Facilities for handling test and control articles... for handling test and control articles. (a) As necessary to prevent contamination or mixups, there shall be separate areas for: (1) Receipt and storage of the test and control articles. (2) Mixing of the...
21 CFR 58.47 - Facilities for handling test and control articles.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 1 2014-04-01 2014-04-01 false Facilities for handling test and control articles... for handling test and control articles. (a) As necessary to prevent contamination or mixups, there shall be separate areas for: (1) Receipt and storage of the test and control articles. (2) Mixing of the...
Battalion Combat Operations Center (COC) Test. Volume II. Test Report,
1982-02-08
reveal, perhaps, that item X can perform a task faster than item-Y. A utility assessment from an experienced, knowledgeable test participant, however...can ascertain whether or not item X can better enable him to accomplish his mission than item Y. 2.4 GENeRALIZED TEST FACILITY. The capabilities of...ATHE MIX D -IX AE4SY MIXES A & C MIX A .IX D M X D IMIX C RATHER DIFFICUJLT VERY DIFFICULT ABILITY TO ABILITY TO ABILITY TO CONTROL DATA EXPLOIT DATA
Wilkinson, Krista; Gravel, Denise; Taylor, Geoffrey; McGeer, Allison; Simor, Andrew; Suh, Kathryn; Moore, Dorothy; Kelly, Sharon; Boyd, David; Mulvey, Michael; Mounchili, Aboubakar; Miller, Mark
2011-04-01
Clostridium difficile is an important pathogen in Canadian health care facilities, and infection prevention and control (IPC) practices are crucial to reducing C difficile infections (CDIs). We performed a cross-sectional study to identify CDI-related IPC practices in Canadian health care facilities. A survey assessing facility characteristics, CDI testing strategies, CDI contact precautions, and antimicrobial stewardship programs was sent to Canadian health care facilities in February 2005. Responses were received from 943 (33%) facilities. Acute care facilities were more likely than long-term care (P < .001) and mixed care facilities (P = .03) to submit liquid stools from all patients for CDI testing. Physician orders were required before testing for CDI in 394 long-term care facilities (66%)-significantly higher than the proportions in acute care (41%; P < .001) and mixed care sites (49%; P < .001). A total of 841 sites (93%) had an infection control manual, 639 (76%) of which contained CDI-specific guidelines. Antimicrobial stewardship programs were reported by 40 (29%) acute care facilities; 19 (54%) of these sites reported full enforcement of the program. Canadian health care facilities have widely varying C difficile IPC practices. Opportunities exist for facilities to take a more active role in IPC policy development and implementation, as well as antimicrobial stewardship. Copyright © 2011 Association for Professionals in Infection Control and Epidemiology, Inc. All rights reserved.
Experimental Supersonic Combustion Research at NASA Langley
NASA Technical Reports Server (NTRS)
Rogers, R. Clayton; Capriotti, Diego P.; Guy, R. Wayne
1998-01-01
Experimental supersonic combustion research related to hypersonic airbreathing propulsion has been actively underway at NASA Langley Research Center (LaRC) since the mid-1960's. This research involved experimental investigations of fuel injection, mixing, and combustion in supersonic flows and numerous tests of scramjet engine flowpaths in LaRC test facilities simulating flight from Mach 4 to 8. Out of this research effort has come scramjet combustor design methodologies, ground test techniques, and data analysis procedures. These technologies have progressed steadily in support of the National Aero-Space Plane (NASP) program and the current Hyper-X flight demonstration program. During NASP nearly 2500 tests of 15 scramjet engine models were conducted in LaRC facilities. In addition, research supporting the engine flowpath design investigated ways to enhance mixing, improve and apply nonintrusive diagnostics, and address facility operation. Tests of scramjet combustor operation at conditions simulating hypersonic flight at Mach numbers up to 17 also have been performed in an expansion tube pulse facility. This paper presents a review of the LaRC experimental supersonic combustion research efforts since the late 1980's, during the NASP program, and into the Hyper-X Program.
Performance of Coarse-Graded Mixes at Westrack - Premature Rutting
DOT National Transportation Integrated Search
1998-06-01
WesTrack is the Federal Highway Administration's (FHWA) test facility in Nevada for developing performance-related specifications for hot-mix asphalt pavement construction. It is also providing some of the earliest data on the performance of Superpav...
The NASA Glen Research Center's Hypersonic Tunnel Facility. Chapter 16
NASA Technical Reports Server (NTRS)
Woike, Mark R.; Willis, Brian P.
2001-01-01
The NASA Glenn Research Center's Hypersonic Tunnel Facility (HTF) is a blow-down, freejet wind tunnel that provides true enthalpy flight conditions for Mach numbers of 5, 6, and 7. The Hypersonic Tunnel Facility is unique due to its large scale and use of non-vitiated (clean air) flow. A 3MW graphite core storage heater is used to heat the test medium of gaseous nitrogen to the high stagnation temperatures required to produce true enthalpy conditions. Gaseous oxygen is mixed into the heated test flow to generate the true air simulation. The freejet test section is 1.07m (42 in.) in diameter and 4.3m (14 ft) in length. The facility is well suited for the testing of large scale airbreathing propulsion systems. In this chapter, a brief history and detailed description of the facility are presented along with a discussion of the facility's application towards hypersonic airbreathing propulsion testing.
Effect of Mixing Enhancement Devices on Turbulence in Separate Flow Nozzles
NASA Technical Reports Server (NTRS)
Bridges, James
2001-01-01
This paper presents the effects of several mixing enhancement devices on turbulence in jet nozzles. The topics include: 1) The Advanced Subsonic Technology (AST) Program; 2) Test Programs SFNT97 and SFNT2K; 3) Facility; 4) Mixing Enhancement Nozzles; 5) IR reductions; 6) Schlieren of Chevrons; and 7) Aeroacoustics of Enhanced Mixing-Paradigm. This paper is presented in viewgraph form.
Tank Pressure Control Experiment on the Space Shuttle
NASA Technical Reports Server (NTRS)
1989-01-01
The tank pressure control experiment is a demonstration of NASA intent to develop new technology for low-gravity management of the cryogenic fluids that will be required for future space systems. The experiment will use freon as the test fluid to measure the effects of jet-induced fluid mixing on storage tank pressure and will produce data on low-gravity mixing processes critical to the design of on-orbit cryogenic storage and resupply systems. Basic data on fluid motion and thermodynamics in low gravity is limited, but such data is critical to the development of space transfer vehicles and spacecraft resupply facilities. An in-space experiment is needed to obtain reliable data on fluid mixing and pressure control because none of the available microgravity test facilities provide a low enough gravity level for a sufficient duration to duplicate in-space flow patterns and thermal processes. Normal gravity tests do not represent the fluid behavior properly; drop-tower tests are limited in length of time available; aircraft low-gravity tests cannot provide the steady near-zero gravity level and long duration needed to study the subtle processes expected in space.
Shock Tunnel Studies of Scramjet Phenomena 1993
NASA Technical Reports Server (NTRS)
Stalker, R. J.; Bakos, R. J.; Morgan, R. G.; Porter, L.; Mee, D.; Paull, A.; Tuttle, S.; Simmons, J. M.; Wendt, M.; Skinner, K.
1995-01-01
Reports by the staff of the University of Queensland on various research studies related to the advancement of scramjet technology and hypervelocity pulse test facilities are presented. These reports document the tests conducted in the reflected shock tunnel T4 and supporting research facilities that have been used to study the injection, mixing, and combustion of hydrogen fuel in generic scramjets at flow conditions typical of hypersonic flight. In addition, topics include the development of instrumentation and measurement technology, such as combustor wall shear and stream composition in pulse facilities, and numerical studies and analyses of the scramjet combustor process and the test facility operation. This research activity is Supplement 10 under NASA Grant NAGw-674.
WTP Waste Feed Qualification: Glass Fabrication Unit Operation Testing Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stone, M. E.; Newell, J. D.; Johnson, F. C.
The waste feed qualification program is being developed to protect the Hanford Tank Waste Treatment and Immobilization Plant (WTP) design, safety basis, and technical basis by assuring waste acceptance requirements are met for each staged waste feed campaign prior to transfer from the Tank Operations Contractor to the feed receipt vessels inside the Pretreatment Facility. The Waste Feed Qualification Program Plan describes the three components of waste feed qualification: 1. Demonstrate compliance with the waste acceptance criteria 2. Determine waste processability 3. Test unit operations at laboratory scale. The glass fabrication unit operation is the final step in the processmore » demonstration portion of the waste feed qualification process. This unit operation generally consists of combining each of the waste feed streams (high-level waste (HLW) and low-activity waste (LAW)) with Glass Forming Chemicals (GFCs), fabricating glass coupons, performing chemical composition analysis before and after glass fabrication, measuring hydrogen generation rate either before or after glass former addition, measuring rheological properties before and after glass former addition, and visual observation of the resulting glass coupons. Critical aspects of this unit operation are mixing and sampling of the waste and melter feeds to ensure representative samples are obtained as well as ensuring the fabrication process for the glass coupon is adequate. Testing was performed using a range of simulants (LAW and HLW simulants), and these simulants were mixed with high and low bounding amounts of GFCs to evaluate the mixing, sampling, and glass preparation steps in shielded cells using laboratory techniques. The tests were performed with off-the-shelf equipment at the Savannah River National Laboratory (SRNL) that is similar to equipment used in the SRNL work during qualification of waste feed for the Defense Waste Processing Facility (DWPF) and other waste treatment facilities at the Savannah River Site. It is not expected that the exact equipment used during this testing will be used during the waste feed qualification testing for WTP, but functionally similar equipment will be used such that the techniques demonstrated would be applicable. For example, the mixing apparatus could use any suitable mixer capable of being remoted and achieving similar mixing speeds to those tested.« less
Nursing home case-mix reimbursement in Mississippi and South Dakota.
Arling, Greg; Daneman, Barry
2002-04-01
To evaluate the effects of nursing home case-mix reimbursement on facility case mix and costs in Mississippi and South Dakota. Secondary data from resident assessments and Medicaid cost reports from 154 Mississippi and 107 South Dakota nursing facilities in 1992 and 1994, before and after implementation of new case-mix reimbursement systems. The study relied on a two-wave panel design to examine case mix (resident acuity) and direct care costs in 1-year periods before and after implementation of a nursing home case-mix reimbursement system. Cross-lagged regression models were used to assess change in case mix and costs between periods while taking into account facility characteristics. Facility-level measures were constructed from Medicaid cost reports and Minimum Data Set-Plus assessment records supplied by each state. Resident case mix was based on the RUG-III classification system. Facility case-mix scores and direct care costs increased significantly between periods in both states. Changes in facility costs and case mix were significantly related in a positive direction. Medicare utilization and the rate of hospitalizations from the nursing facility also increased significantly between periods, particularly in Mississippi. The case-mix reimbursement systems appeared to achieve their intended goals: improved access for heavy-care residents and increased direct care expenditures in facilities with higher acuity residents. However, increases in Medicare utilization may have influenced facility case mix or costs, and some facilities may have been unprepared to care for higher acuity residents, as indicated by increased rates of hospitalization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Waterland, L.; Lee, J.W.
1989-04-01
A series of demonstration tests of the American Combustion, Inc., Thermal Destruction System was performed under the SITE program. This oxygen-enhanced combustion system was retrofit to the rotary-kiln incinerator at EPA's Combustion Research Facility. The system's performance was tested firing contaminated soil from the Stringfellow Superfund Site, both alone and mixed with a coal tar waste (KO87). Comparative performance with conventional incinerator operation was also tested. Compliance with the incinerator performance standards of 99.99% principal organic hazardous constituents (POHC) destruction and removal efficiency and particulate emissions of less than 180 mg/dscm at 7% O2 was measured for all tests. Themore » Pyretron system was capable of in-compliance performance at double the mixed waste feedrate and at a 60% increase in batch waste charge mass than possible with conventional incineration. Scrubber blowdown and kiln ash contained no detectable levels of any of the POHCs chosen.« less
NASA Technical Reports Server (NTRS)
Drozda, Tomasz G.; Cabell, Karen F.; Passe, Bradley J.; Baurle, Robert A.
2017-01-01
Computational fluid dynamics analyses and experimental data are presented for the Mach 6 facility nozzle used in the Arc-Heated Scramjet Test Facility for the Enhanced Injection and Mixing Project (EIMP). This project, conducted at the NASA Langley Research Center, aims to investigate supersonic combustion ramjet (scramjet) fuel injection and mixing physics relevant to flight Mach numbers greater than 8. The EIMP experiments use a two-dimensional Mach 6 facility nozzle to provide the high-speed air simulating the combustor entrance flow of a scramjet engine. Of interest are the physical extent and the thermodynamic properties of the core flow at the nozzle exit plane. The detailed characterization of this flow is obtained from three-dimensional, viscous, Reynolds-averaged simulations. Thermodynamic nonequilibrium effects are also investigated. The simulations are compared with the available experimental data, which includes wall static pressures as well as in-stream static pressure, pitot pressure and total temperature obtained via in-stream probes positioned just downstream of the nozzle exit plane.
40 CFR 60.93 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Test methods and procedures. 60.93... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Hot Mix Asphalt Facilities § 60.93 Test methods and procedures. (a) In conducting the performance tests required in § 60.8...
Shock tunnel studies of scramjet phenomena, supplement 6
NASA Technical Reports Server (NTRS)
Wendt, M.; Nettleton, M.; Morgan, R. G.; Skinner, K.; Casey, R.; Stalker, R.; Brescianini, C.; Paull, A.; Allen, G.; Smart, M.
1993-01-01
Reports by the staff of the University of Queensland on various research studies related to the advancement of scramjet technology are presented. These reports document the tests conducted in the reflected shock tunnel T4 and supporting research facilities that have been used to study the injection, mixing, and combustion of hydrogen fuel in generic scramjets at flow conditions typical of hypersonic flight. In addition, topics include the development of instrumentation and measurement technology, such as combustor wall shear and stream composition in pulse facilities, and numerical studies and analyses of the scramjet combustor process and the test facility operation.
40 CFR 60.90 - Applicability and designation of affected facility.
Code of Federal Regulations, 2010 CFR
2010-07-01
... for Hot Mix Asphalt Facilities § 60.90 Applicability and designation of affected facility. (a) The affected facility to which the provisions of this subpart apply is each hot mix asphalt facility. For the purpose of this subpart, a hot mix asphalt facility is comprised only of any combination of the following...
40 CFR 60.90 - Applicability and designation of affected facility.
Code of Federal Regulations, 2013 CFR
2013-07-01
... for Hot Mix Asphalt Facilities § 60.90 Applicability and designation of affected facility. (a) The affected facility to which the provisions of this subpart apply is each hot mix asphalt facility. For the purpose of this subpart, a hot mix asphalt facility is comprised only of any combination of the following...
40 CFR 60.90 - Applicability and designation of affected facility.
Code of Federal Regulations, 2012 CFR
2012-07-01
... for Hot Mix Asphalt Facilities § 60.90 Applicability and designation of affected facility. (a) The affected facility to which the provisions of this subpart apply is each hot mix asphalt facility. For the purpose of this subpart, a hot mix asphalt facility is comprised only of any combination of the following...
40 CFR 60.90 - Applicability and designation of affected facility.
Code of Federal Regulations, 2014 CFR
2014-07-01
... for Hot Mix Asphalt Facilities § 60.90 Applicability and designation of affected facility. (a) The affected facility to which the provisions of this subpart apply is each hot mix asphalt facility. For the purpose of this subpart, a hot mix asphalt facility is comprised only of any combination of the following...
40 CFR 60.90 - Applicability and designation of affected facility.
Code of Federal Regulations, 2011 CFR
2011-07-01
... for Hot Mix Asphalt Facilities § 60.90 Applicability and designation of affected facility. (a) The affected facility to which the provisions of this subpart apply is each hot mix asphalt facility. For the purpose of this subpart, a hot mix asphalt facility is comprised only of any combination of the following...
Journey to the Nevada Test Site Radioactive Waste Management Complex
None
2018-01-16
Journey to the Nevada Test Site Radioactive Waste Management Complex begins with a global to regional perspective regarding the location of low-level and mixed low-level waste disposal at the Nevada Test Site. For decades, the Nevada National Security Site (NNSS) has served as a vital disposal resource in the nation-wide cleanup of former nuclear research and testing facilities. State-of-the-art waste management sites at the NNSS offer a safe, permanent disposal option for U.S. Department of Energy/U.S. Department of Defense facilities generating cleanup-related radioactive waste.
Applying RUG-III in Japanese Long-Term Care Facilities.
ERIC Educational Resources Information Center
Ikegami, Naoki; And Others
1994-01-01
Tested U.S. nursing home case-mix system, Resource Utilization Groups, Version III (RUG-III) in Japanese long-term care facilities. Measured staff time and resident characteristics for 871 patients. Found acceptable reliability for items defining RUG-III, and system explained 44% of variance in wage-weighted staff time (cost). Japanese and U.S.…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bryner, Elliott; Brun, Klaus; Coogan, Shane
The objective of this project is to increase Concentrated Solar Power (CSP) tower air receiver and gas turbine temperature capabilities to 1,000ºC by the development of a novel gas turbine combustor, which can be integrated on a megawatt-scale gas turbine, such as the Solar Turbines Mercury 50™. No combustor technology currently available is compatible with the CSP application target inlet air temperature of 1,000°C. Autoignition and flashback at this temperature prevent the use of conventional lean pre-mix injectors that are currently employed to manage NOx emissions. Additional challenges are introduced by the variability of the high-temperature heat source provided bymore » the field of solar collectors, the heliostat in CSP plants. For optimum energy generation from the power turbine, the turbine rotor inlet temperature (TRIT) should remain constant. As a result of changing heat load provided to the solar collector from the heliostat, the amount of energy input required from the combustion system must be adjusted to compensate. A novel multi-bank lean micro-mix injector has been designed and built to address the challenges of high-temperature combustion found in CSP applications. The multi-bank arrangement of the micro-mix injector selectively injects fuel to meet the heat addition requirements to maintain constant TRIT with changing solar load. To validate the design, operation, and performance of the multi-bank lean micro-mix injector, a novel combustion test facility has been designed and built at Southwest Research Institute® (SwRI®) in San Antonio, TX. This facility, located in the Turbomachinery Research Facility, provides in excess of two kilograms per second of compressed air at nearly eight bar pressure. A two-megawatt electric heater raises the inlet temperature to 800°C while a secondary gas-fired heater extends the operational temperature range of the facility to 1,000°C. A combustor test rig connected to the heater has been designed and built to test the multi-bank lean micro-mix injector over the range of CSP operating conditions. The fuel is controlled and selectively delivered to the banks of the injector based on combustor inlet conditions that correspond to turbine operating points. The combustor rig is equipped with a data acquisition system and a suite of instrumentation for measuring temperature, pressure, and species concentration. This unique test facility has been built and commissioned and a prototype of the multi-bank lean micro-mix injector design has been tested. Operation of the combustor and injector has been demonstrated over the full range of CSP inlet conditions and for the range of turbine load conditions specified. The multi-bank operation of the injector has been proven to be an effective design for managing the variable flow rates of air and fuel due to changing inlet conditions from the solar field and turbine loads.« less
Hot-flow tests of a series of 10-percent-scale turbofan forced mixing nozzles
NASA Technical Reports Server (NTRS)
Head, V. L.; Povinelli, L. A.; Gerstenmaier, W. H.
1984-01-01
An approximately 1/10-scale model of a mixed-flow exhaust system was tested in a static facility with fully simulated hot-flow cruise and takeoff conditions. Nine mixer geometries with 12 to 24 lobes were tested. The areas of the core and fan stream were held constant to maintain a bypass ratio of approximately 5. The research results presented in this report were obtained as part of a program directed toward developing an improved mixer design methodology by using a combined analytical and experimental approach. The effects of lobe spacing, lobe penetration, lobe-to-centerbody gap, lobe contour, and scalloping of the radial side walls were investigated. Test measurements included total pressure and temperature surveys, flow angularity surveys, and wall and centerbody surface static pressure measurements. Contour plots at various stations in the mixing region are presented to show the mixing effectiveness for the various lobe geometries.
2012-06-01
AFRL facility was well suited for the Themis cold flow experiment. A test cell was selected that contained an insulated cryogenic oxygen tank that...could be used for the LN2 supply. Adjacent to the test cell is a cryogenic storage bunker that contained a helium supply tank with existing high...venturi to the fuel bunker tank was very low (less than 25 psi) while the helium pressure drop from the cryogenic storage bunker was almost 2000 psi
Facility-level association of preoperative stress testing and postoperative adverse cardiac events.
Valle, Javier A; Graham, Laura; Thiruvoipati, Thejasvi; Grunwald, Gary; Armstrong, Ehrin J; Maddox, Thomas M; Hawn, Mary T; Bradley, Steven M
2018-06-22
Despite limited indications, preoperative stress testing is often used prior to non-cardiac surgery. Patient-level analyses of stress testing and outcomes are limited by case mix and selection bias. Therefore, we sought to describe facility-level rates of preoperative stress testing for non-cardiac surgery, and to determine the association between facility-level preoperative stress testing and postoperative major adverse cardiac events (MACE). We identified patients undergoing non-cardiac surgery within 2 years of percutaneous coronary intervention in the Veterans Affairs (VA) Health Care System, from 2004 to 2011, facility-level rates of preoperative stress testing and postoperative MACE (death, myocardial infarction (MI) or revascularisation within 30 days). We determined risk-standardised facility-level rates of stress testing and postoperative MACE, and the relationship between facility-level preoperative stress testing and postoperative MACE. Among 29 937 patients undergoing non-cardiac surgery at 131 VA facilities, the median facility rate of preoperative stress testing was 13.2% (IQR 9.7%-15.9%; range 6.0%-21.5%), and 30-day postoperative MACE was 4.0% (IQR 2.4%-5.4%). After risk standardisation, the median facility-level rate of stress testing was 12.7% (IQR 8.4%-17.4%) and postoperative MACE was 3.8% (IQR 2.3%-5.6%). There was no correlation between risk-standardised stress testing and composite MACE at the facility level (r=0.022, p=0.81), or with individual outcomes of death, MI or revascularisation. In a national cohort of veterans undergoing non-cardiac surgery, we observed substantial variation in facility-level rates of preoperative stress testing. Facilities with higher rates of preoperative stress testing were not associated with better postoperative outcomes. These findings suggest an opportunity to reduce variation in preoperative stress testing without sacrificing patient outcomes. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Evaporative oxidation treatability test report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-04-01
In 1992, Congress passed the Federal Facilities Compliance Act that requires the U.S. Department of Energy (DOE) to treat and dispose of its mixed waste in accordance with the Resource Conservation and Recovery Act (RCRA) land disposal restrictions (LDRs). In response to the need for mixed-waste treatment capacity where available off-site commercial treatment facilities do not exist or cannot be used, the DOE Albuquerque Operations Office (DOE-AL) organized a Treatment Selection Team to match mixed wastes with treatment options and develop a strategy for treatment of its mixed wastes. DOE-AL manages operations at nine sites with mixed-waste inventories. The Treatmentmore » Selection Team determined a need to develop mobile treatment capacity to treat wastes at the sites where the wastes are generated. Treatment processes used for mixed waste not only must address the hazardous component (i.e., meet LDRs) but also must contain the radioactive component in a form that allows final disposal while protecting workers, the public, and the environment. On the basis of recommendations of the Treatment Selection Team, DOE-AL assigned projects to the sites to bring mixed-waste treatment capacity on-line. The three technologies assigned to the DOE Grand Junction Projects Office (GJPO) are evaporative oxidation, thermal desorption, and treated wastewater evaporation. Rust Geotech, the DOE-GJPO prime contractor, was assigned to design and fabricate mobile treatment units (MTUs) for these three technologies and to deliver the MTUs to selected DOE-AL sites. To conduct treatability tests at the GJPO, Rust leased a pilot-scale evaporative oxidation unit from the Clemson Technical Center (CTC), Anderson, South Carolina. The purpose of this report is to document the findings and results of tests performed using this equipment.« less
Shock tunnel studies of scramjet phenomena, supplement 8
NASA Technical Reports Server (NTRS)
Stalker, R. J.; Hollis, P.; Allen, G. A.; Roberts, G. T.; Tuttle, S.; Bakos, R. J.; Morgan, R. G.; Pulsonetti, M. V.; Brescianini, C.; Buttsworth, D. R.
1993-01-01
Reports by the staff of the University of Oueensland on various research studies related to the advancement of scramjet technology are presented. These reports document the tests conducted in the reflected shock tunnel T4 and supporting research facilities that have been used to study the injection, mixing, and combustion of hydrogen fuel in generic scramjets at flow conditions typical of hypersonic flight. In addition, topics include the development of instrumentation and measurement technology, such as combustor wall shear and stream composition in pulse facilities, and numerical studies and analyses of the scramjet combustor process and the test facility operation. This research activity is Supplement 8 under NASA Grant NAGW-674.
Shock tunnel studies of scramjet phenomena, supplement 7
NASA Technical Reports Server (NTRS)
Bakos, R. J.; Morgan, R. G.; Tuttle, S. L.; Kelly, G. M.; Paull, A.; Simmons, J. M.; Stalker, R. J.; Pulsonetti, M. V.; Buttsworth, D.; Allen, G. A., Jr.
1993-01-01
Reports by the staff of the University of Queensland on various research studies related to the advancement of scramjet technology are presented. These reports document the tests conducted in the reflected shock tunnel T4 and supporting research facilities that have been used to study the injection, mixing, and combustion of hydrogen fuel in generic scramjets at flow conditions typical of hypersonic flight. In addition, topics include the development of instrumentation and measurement technology, such as combustor wall shear and stream composition in pulse facilities, and numerical studies and analyses of the scramjet combustor process and the test facility operation. This research activity is Supplement 7 under NASA Grant NAGW-674.
Code of Federal Regulations, 2012 CFR
2012-07-01
... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Hot Mix Asphalt Facilities § 60.91... Act and in subpart A of this part. (a) Hot mix asphalt facility means any facility, as described in § 60.90, used to manufacture hot mix asphalt by heating and drying aggregate and mixing with asphalt...
Code of Federal Regulations, 2011 CFR
2011-07-01
... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Hot Mix Asphalt Facilities § 60.91... Act and in subpart A of this part. (a) Hot mix asphalt facility means any facility, as described in § 60.90, used to manufacture hot mix asphalt by heating and drying aggregate and mixing with asphalt...
Code of Federal Regulations, 2014 CFR
2014-07-01
... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Hot Mix Asphalt Facilities § 60.91... Act and in subpart A of this part. (a) Hot mix asphalt facility means any facility, as described in § 60.90, used to manufacture hot mix asphalt by heating and drying aggregate and mixing with asphalt...
Code of Federal Regulations, 2010 CFR
2010-07-01
... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Hot Mix Asphalt Facilities § 60.91... Act and in subpart A of this part. (a) Hot mix asphalt facility means any facility, as described in § 60.90, used to manufacture hot mix asphalt by heating and drying aggregate and mixing with asphalt...
Code of Federal Regulations, 2013 CFR
2013-07-01
... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Hot Mix Asphalt Facilities § 60.91... Act and in subpart A of this part. (a) Hot mix asphalt facility means any facility, as described in § 60.90, used to manufacture hot mix asphalt by heating and drying aggregate and mixing with asphalt...
Variation in fistula use across dialysis facilities: is it explained by case-mix?
Tangri, Navdeep; Moorthi, Ranjani; Tighiouhart, Hocine; Meyer, Klemens B; Miskulin, Dana C
2010-02-01
Arteriovenous fistulas (AVFs) remain the preferred vascular access for hemodialysis patients. Dialysis facilities that fail to meet Centers for Medicare & Medicaid Services goals cite patient case-mix as a reason for low AVF prevalence. This study aimed to determine the magnitude of the variability in AVF usage across dialysis facilities and the extent to which patient case-mix explains it. The vascular access used in 10,112 patients dialyzed at 173 Dialysis Clinic Inc. facilities from October 1 to December 31, 2004, was evaluated. The access in use was considered to be an AVF if it was used for >70% of hemodialysis treatments. Mixed-effects models with a random intercept for dialysis facilities evaluated the effect of facilities on AVF usage. Sequentially adjusted multivariate models measured the extent to which patient factors (case-mix) explain variation across facilities in AVF rates. 3787 patients (38%) were dialyzed using AVFs. There was a significant facility effect: 7.6% of variation in AVF use was attributable to facility. This was reduced to 7.1% after case-mix adjustment. There were no identified specific facility-level factors that explained the interfacility variation. AVF usage varies across dialysis facilities, and patient case-mix did not reduce this variation. In this study, 92% of the total variation in AVF usage was due to patient factors, but most were not measurable. A combination of patient factors and process indicators should be considered in adjudicating facility performance for this quality indicator.
NASA Astrophysics Data System (ADS)
Winkel, B. V.
1995-03-01
The purpose of this report is to document the Multi-Function Waste Tank Facility (MWTF) Project position on the concrete mechanical properties needed to perform design/analysis calculations for the MWTF secondary concrete structure. This report provides a position on MWTF concrete properties for the Title 1 and Title 2 calculations. The scope of the report is limited to mechanical properties and does not include the thermophysical properties of concrete needed to perform heat transfer calculations. In the 1970's, a comprehensive series of tests were performed at Construction Technology Laboratories (CTL) on two different Hanford concrete mix designs. Statistical correlations of the CTL data were later generated by Pacific Northwest Laboratories (PNL). These test results and property correlations have been utilized in various design/analysis efforts of Hanford waste tanks. However, due to changes in the concrete design mix and the lower range of MWTF operating temperatures, plus uncertainties in the CTL data and PNL correlations, it was prudent to evaluate the CTL data base and PNL correlations, relative to the MWTF application, and develop a defendable position. The CTL test program for Hanford concrete involved two different mix designs: a 3 kip/sq in mix and a 4.5 kip/sq in mix. The proposed 28-day design strength for the MWTF tanks is 5 kip/sq in. In addition to this design strength difference, there are also differences between the CTL and MWTF mix design details. Also of interest, are the appropriate application of the MWTF concrete properties in performing calculations demonstrating ACI Code compliance. Mix design details and ACI Code issues are addressed in Sections 3.0 and 5.0, respectively. The CTL test program and PNL data correlations focused on a temperature range of 250 to 450 F. The temperature range of interest for the MWTF tank concrete application is 70 to 200 F.
Coherent Anti-Stokes Raman Scattering (CARS) as a Probe for Supersonic Hydrogen-Fuel/Air Mixing
NASA Technical Reports Server (NTRS)
Danehy, P. M.; O'Byrne, S.; Cutler, A. D.; Rodriguez, C. G.
2003-01-01
The dual-pump coherent anti-Stokes Raman spectroscopy (CARS) method was used to measure temperature and the absolute mole fractions of N2, O2 and H2 in a supersonic non-reacting fuel-air mixing experiment. Experiments were conducted in NASA Langley Research Center s Direct Connect Supersonic Combustion Test Facility. Under normal operation of this facility, hydrogen and air burn to increase the enthalpy of the test gas and O2 is added to simulate air. This gas is expanded through a Mach 2 nozzle and into a combustor model where fuel is then injected, mixes and burns. In the present experiment the O2 of the test gas is replaced by N2. The lack of oxidizer inhibited combustion of the injected H2 fuel jet allowing the fuel/air mixing process to be studied. CARS measurements were performed 427 mm downstream of the nozzle exit and 260 mm downstream of the fuel injector. Maps were obtained of the mean temperature, as well as the N2, O2 and H2 mean mole fraction fields. A map of mean H2O vapor mole fraction was also inferred from these measurements. Correlations between different measured parameters and their fluctuations are presented. The CARS measurements are compared with a preliminary computational prediction of the flow.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillips, S.J.; Phillips, M.; Etheridge, D.
2012-07-01
Per regulatory agreement and facility closure design, U.S. Department of Energy Hanford Site nuclear fuel cycle structures and materials require in situ isolation in perpetuity and/or interim physicochemical stabilization as a part of final disposal or interim waste removal, respectively. To this end, grout materials are being used to encase facilities structures or are being incorporated within structures containing hazardous and radioactive contaminants. Facilities where grout materials have been recently used for isolation and stabilization include: (1) spent fuel separations, (2) uranium trioxide calcining, (3) reactor fuel storage basin, (4) reactor fuel cooling basin transport rail tanker cars and casks,more » (5) cold vacuum drying and reactor fuel load-out, and (6) plutonium fuel metal finishing. Grout components primarily include: (1) portland cement, (2) fly ash, (3) aggregate, and (4) chemical admixtures. Mix designs for these typically include aggregate and non aggregate slurries and bulk powders. Placement equipment includes: (1) concrete piston line pump or boom pump truck for grout slurry, (2) progressive cavity and shearing vortex pump systems, and (3) extendable boom fork lift for bulk powder dry grout mix. Grout slurries placed within the interior of facilities were typically conveyed utilizing large diameter slick line and the equivalent diameter flexible high pressure concrete conveyance hose. Other facilities requirements dictated use of much smaller diameter flexible grout conveyance hose. Placement required direct operator location within facilities structures in most cases, whereas due to radiological dose concerns, placement has also been completed remotely with significant standoff distances. Grout performance during placement and subsequent to placement often required unique design. For example, grout placed in fuel basin structures to serve as interim stabilization materials required sufficient bearing i.e., unconfined compressive strength, to sustain heavy equipment yet, low breakout force to permit efficient removal by track hoe bucket or equivalent construction equipment. Further, flow of slurries through small orifice geometries of moderate head pressures was another typical design requirement. Phase separation of less than 1 percent was a typical design requirement for slurries. On the order of 30,000 cubic meters of cementitious grout have recently been placed in the above noted U.S. Department of Energy Hanford Site facilities or structures. Each has presented a unique challenge in mix design, equipment, grout injection or placement, and ultimate facility or structure performance. Unconfined compressive and shear strength, flow, density, mass attenuation coefficient, phase separation, air content, wash-out, parameters and others, unique to each facility or structure, dictate the grout mix design for each. Each mix design was tested under laboratory and scaled field conditions as a precursor to field deployment. Further, after injection or placement of each grout formulation, the material was field inspected either by standard laboratory testing protocols, direct physical evaluation, or both. (authors)« less
Qualification test of the Ross Double Planetary Mixer
NASA Technical Reports Server (NTRS)
Lueders, Kurt F.
1993-01-01
This test report describes the qualification test of the Ross Double Planetary Mixer used to mix room temperature vulcanized (RTV) silicone (Dow Corning 90-006-2) for the redesigned solid rocket motor (RSRM) nozzle joints. Testing was completed 18 June 1993 in the M-113A Nozzle Fabrication Facility at Thiokol Corporation, Space Operations, Brigham City, Utah. The Ross mixer provides better mixing and better control on temperature and humidity, resulting in better quality RTV and a longer usable pot life. The test began on 3 May 1993 and was stopped due to operator error during the tensile strength and elongation testing. Specimens were ruined without gathering any useful data. A 'no test' was declared, the problem was remedied, and the test was re-run with MSFC approval. The test was run and all pass/fail criteria were met, most with a considerable margin. The Ross Double Planetary Mixer met all certification objectives and is recommended for immediate use for mixing RTV silicone for RSRM nozzle joints.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oden, L.L.; O`Connor, W.K.; Turner, P.C.
1993-11-19
This report presents field results and raw data from the Buried Waste Integrated Demonstration (BWID) Arc Melter Vitrification Project Phase 1 baseline test series conducted by the Idaho National Engineering Laboratory (INEL) in cooperation with the U.S. Bureau of Mines (USBM). The baseline test series was conducted using the electric arc melter facility at the USBM Albany Research Center in Albany, Oregon. Five different surrogate waste feed mixtures were tested that simulated thermally-oxidized, buried, TRU-contaminated, mixed wastes and soils present at the INEL. The USBM Arc Furnace Integrated Waste Processing Test Facility includes a continuous feed system, the arc meltingmore » furnace, an offgas control system, and utilities. The melter is a sealed, 3-phase alternating current (ac) furnace approximately 2 m high and 1.3 m wide. The furnace has a capacity of 1 metric ton of steel and can process as much as 1,500 lb/h of soil-type waste materials. The surrogate feed materials included five mixtures designed to simulate incinerated TRU-contaminated buried waste materials mixed with INEL soil. Process samples, melter system operations data and offgas composition data were obtained during the baseline tests to evaluate the melter performance and meet test objectives. Samples and data gathered during this program included (a) automatically and manually logged melter systems operations data, (b) process samples of slag, metal and fume solids, and (c) offgas composition, temperature, velocity, flowrate, moisture content, particulate loading and metals content. This report consists of 2 volumes: Volume I summarizes the baseline test operations. It includes an executive summary, system and facility description, review of the surrogate waste mixtures, and a description of the baseline test activities, measurements, and sample collection. Volume II contains the raw test data and sample analyses from samples collected during the baseline tests.« less
LeRC NATR Free-Jet Development
NASA Technical Reports Server (NTRS)
Long-Davis, M.; Cooper, B. A.
1999-01-01
The Nozzle Acoustic Test Rig (NATR) was developed to provide additional test capabilities at Lewis needed to meet HSR program goals. The NATR is a large f ree-jet facility (free-jet diameter = 53 in.) with a design Mach number of 0.3. It is located inside a geodesic dome, adjacent to the existing Powered Lift Facility (PLF). The NATR allows nozzle concepts to be acoustically assessed for far-field (approximately 50 feet) noise characteristics under conditions simulating forward flight. An ejector concept was identified as a means of supplying the required airflow for this free-jet facility. The primary stream is supplied through a circular array of choked nozzles and the resulting low pressure in the constant, annular- area mixing section causes a "pumping" action that entrains the secondary stream. The mixed flow expands through an annular diffuser and into a plenum chamber. Once inside the plenum, the flow passes over a honeycomb/screen combination intended to remove large disturbances and provide uniform flow. The flow accelerates through an elliptical contraction section where it achieves a free-jet Mach number of up to 0.3.
Ouma, Paul O; Agutu, Nathan O; Snow, Robert W; Noor, Abdisalan M
2017-09-18
Precise quantification of health service utilisation is important for the estimation of disease burden and allocation of health resources. Current approaches to mapping health facility utilisation rely on spatial accessibility alone as the predictor. However, other spatially varying social, demographic and economic factors may affect the use of health services. The exclusion of these factors can lead to the inaccurate estimation of health facility utilisation. Here, we compare the accuracy of a univariate spatial model, developed only from estimated travel time, to a multivariate model that also includes relevant social, demographic and economic factors. A theoretical surface of travel time to the nearest public health facility was developed. These were assigned to each child reported to have had fever in the Kenya demographic and health survey of 2014 (KDHS 2014). The relationship of child treatment seeking for fever with travel time, household and individual factors from the KDHS2014 were determined using multilevel mixed modelling. Bayesian information criterion (BIC) and likelihood ratio test (LRT) tests were carried out to measure how selected factors improve parsimony and goodness of fit of the time model. Using the mixed model, a univariate spatial model of health facility utilisation was fitted using travel time as the predictor. The mixed model was also used to compute a multivariate spatial model of utilisation, using travel time and modelled surfaces of selected household and individual factors as predictors. The univariate and multivariate spatial models were then compared using the receiver operating area under the curve (AUC) and a percent correct prediction (PCP) test. The best fitting multivariate model had travel time, household wealth index and number of children in household as the predictors. These factors reduced BIC of the time model from 4008 to 2959, a change which was confirmed by the LRT test. Although there was a high correlation of the two modelled probability surfaces (Adj R 2 = 88%), the multivariate model had better AUC compared to the univariate model; 0.83 versus 0.73 and PCP 0.61 versus 0.45 values. Our study shows that a model that uses travel time, as well as household and individual-level socio-demographic factors, results in a more accurate estimation of use of health facilities for the treatment of childhood fever, compared to one that relies on only travel time.
The CELSS Test Facility Project - An example of a CELSS flight experiment system
NASA Technical Reports Server (NTRS)
Macelroy, R. D.; Straight, C. L.
1992-01-01
The design of the facility is described in terms of its use as an investigation tool for evaluating crop growth in space with reference to required emerging technologies. NASA's CELSS Test Facility (CTF) is designed to permit the measurement of crop-plant productivity under microgravity conditions including biomass production, food production, water transpiration, and O2/CO2 exchanges. Crucial hardware tests and qualifications are identified to assure the operation of CTF technologies in space including the nutrient-delivery, water-condensation, and gas-liquid-mixing subsystems. The design concept and related scientific requirements are described and shown to provide microgravity crop research. The CTF is expected to provide data for plant research and for concepts for bioregenerative life-support systems for applications to Martian, lunar, and space-station missions.
Testing a diagnosis-related group index for skilled nursing facilities
Cotterill, Philip G.
1986-01-01
Interest in case-mix measures for use in nursing home payment systems has been stimulated by the Medicare prospective payment system (PPS) for short-term acute-care hospitals. Appropriately matching payment with care needs is important to equitably compensate providers and to encourage them to admit patients who are most in need of nursing home care. The skilled nursing facility (SNF) Medicare benefit covers skilled convalescent or rehabilitative care following a hospital stay. Therefore, it might appear that diagnosis-related groups (DRG's), the basis for patient classification in PPS, could also be used for the Medicare SNF program. In this study, a DRG-based case-mix index (CMI) was developed and tested to determine how well it explains cost differences among SNF's. The results suggest that a DRG-based SNF payment system would be highly problematic. Incentives of this system would appear to discourage placement of patients who require relatively expensive care. PMID:10311674
Testing a diagnosis-related group index for skilled nursing facilities.
Cotterill, P G
1986-01-01
Interest in case-mix measures for use in nursing home payment systems has been stimulated by the Medicare prospective payment system (PPS) for short-term acute-care hospitals. Appropriately matching payment with care needs is important to equitably compensate providers and to encourage them to admit patients who are most in need of nursing home care. The skilled nursing facility (SNF) Medicare benefit covers skilled convalescent or rehabilitative care following a hospital stay. Therefore, it might appear that diagnosis-related groups (DRG's), the basis for patient classification in PPS, could also be used for the Medicare SNF program. In this study, a DRG-based case-mix index (CMI) was developed and tested to determine how well it explains cost differences among SNF's. The results suggest that a DRG-based SNF payment system would be highly problematic. Incentives of this system would appear to discourage placement of patients who require relatively expensive care.
Facility design consideration for continuous mix production of class 1.3 propellant
NASA Technical Reports Server (NTRS)
Williamson, K. L.; Schirk, P. G.
1994-01-01
In November of 1989, NASA awarded the Advanced Solid Rocket Motor (ASRM) contract to Lockheed Missiles and Space Company (LMSC) for production of advanced solid rocket motors using the continuous mix process. Aerojet ASRM division (AAD) was selected as the facility operator and RUST International Corporation provided the engineering, procurement, and construction management services. The continuous mix process mandates that the mix and cast facilities be 'close-coupled' along with the premix facilities, creating unique and challenging requirements for the facility designer. The classical approach to handling energetic materials-division into manageable quantities, segregation, and isolation-was not available due to these process requirements and quantities involved. This paper provides a description of the physical facilities, the continuous mix process, and discusses the monitoring and detection techniques used to mitigate hazards and prevent an incident.
Rosenberg, Dori; Ding, Ding; Sallis, James F; Kerr, Jacqueline; Norman, Gregory J; Durant, Nefertiti; Harris, Sion K; Saelens, Brian E
2009-01-01
To examine the psychometric properties of the Neighborhood Environment Walkability Scale-Youth (NEWS-Y) and explore its associations with context-specific and overall physical activity (PA) among youth. In 2005, parents of children ages 5-11 (n=116), parents of adolescents ages 12-18 (n=171), and adolescents ages 12-18 (n=171) from Boston, Cincinnati, and San Diego, completed NEWS-Y surveys regarding perceived land use mix-diversity, recreation facility availability, pedestrian/automobile traffic safety, crime safety, aesthetics, walking/cycling facilities, street connectivity, land use mix-access, and residential density. A standardized neighborhood environment score was derived. Self-reported activity in the street and in parks, and walking to parks, shops, school, and overall physical activity were assessed. The NEWS-Y subscales had acceptable test-retest reliability (ICC range .56-.87). Being active in a park, walking to a park, walking to shops, and walking to school were related to multiple environmental attributes in all three participant groups. Total neighborhood environment, recreation facilities, walking and cycling facilities, and land use mix-access had the most consistent relationships with specific types of activity. The NEWS-Y has acceptable reliability and subscales were significantly correlated with specific types of youth PA. The NEWS-Y can be used to examine neighborhood environment correlates of youth PA.
Superpave Mixture Design Guide : Westrack Forensic Team Consensus Report
DOT National Transportation Integrated Search
2001-02-02
WesTrack was the Federal Highway Administration's (FHWA) test facility in Nevada for developing performance-related specifications for hot-mix asphalt pavement construction. It also provided some of the earliest data on the performance of Superpave a...
Rating long-term care facilities on pressure ulcer development: importance of case-mix adjustment.
Berlowitz, D R; Ash, A S; Brandeis, G H; Brand, H K; Halpern, J L; Moskowitz, M A
1996-03-15
To determine the importance of case-mix adjustment in interpreting differences in rates of pressure ulcer development in Department of Veterans Affairs long- term care facilities. A sample assembled from the Patient Assessment File, a Veterans Affairs administrative database, was used to derive predictors of pressure ulcer development; the resulting model was validated in a separate sample. Facility-level rates of pressure ulcer development, both unadjusted and adjusted for case mix using the predictive model, were compared. Department of Veterans Affairs long-term care facilities. The derivation sample consisted of 31 150 intermediate medicine and nursing home residents who were initially free of pressure ulcers and were institutionalized between October 1991 and April 1993. The validation sample consisted of 17 946 residents institutionalized from April 1993 to October 1993. Development of a stage 2 or greater pressure ulcer. 11 factors predicted pressure ulcer development. Validated performance properties of the resulting model were good. Model-predicted rates of pressure ulcer development at individual long-term care facilities varied from 1.9% to 6.3%, and observed rates ranged from 0% to 10.9%. Case-mix-adjusted rates and ranks of facilities differed considerably from unadjusted ratings. For example, among five facilities that were identified as high outliers on the basis of unadjusted rates, two remained as outliers after adjustment for case mix. Long-term care facilities differ in case mix. Adjustments for case mix result in different judgments about facility performance and should be used when facility incidence rates are compared.
NASA Technical Reports Server (NTRS)
Herkes, William
2000-01-01
Acoustic and propulsion performance testing of a model-scale Axisymmetric Coannular Ejector nozzle was conducted in the Boeing Low-speed Aeroacoustic Facility. This nozzle is a plug nozzle with an ejector design to provide aspiration of about 20% of the engine flow. A variety of mixing enhancers were designed to promote mixing of the engine and the aspirated flows. These included delta tabs, tone-injection rods, and wheeler ramps. This report addresses the acoustic aspects of the testing. The spectral characteristics of the various configurations of the nozzle are examined on a model-scale basis. This includes indentifying particular noise sources contributing to the spectra and the data are projected to full-scale flyover conditions to evaluate the effectiveness of the nozzle, and of the various mixing enhancers, on reducing the Effective Perceived Noise Levels.
Community noise sources and noise control issues
NASA Technical Reports Server (NTRS)
Nihart, Gene L.
1992-01-01
The topics covered include the following: community noise sources and noise control issues; noise components for turbine bypass turbojet engine (TBE) turbojet; engine cycle selection and noise; nozzle development schedule; NACA nozzle design; NACA nozzle test results; nearly fully mixed (NFM) nozzle design; noise versus aspiration rate; peak noise test results; nozzle test in the Low Speed Aeroacoustic Facility (LSAF); and Schlieren pictures of NACA nozzle.
Application of DPIV to Enhanced Mixing Heated Nozzle Flows
NASA Technical Reports Server (NTRS)
Wernet, Mark P.; Bridges, James
2002-01-01
Digital Particle Imaging Velocimetry (DPIV) is a planar velocity measurement technique that continues to be applied to new and challenging engineering research facilities while significantly reducing facility test time. DPIV was used in the GRC Nozzle Acoustic Test Rig (NATR) to characterize the high temperature (560 C), high speed (is greater than 500 m/s) flow field properties of mixing enhanced jet engine nozzles. The instantaneous velocity maps obtained using DPIV were used to determine mean velocity, rms velocity and two-point correlation statistics to verify the true turbulence characteristics of the flow. These measurements will ultimately be used to properly validate aeroacoustic model predictions by verifying CFD input to these models. These turbulence measurements have previously not been possible in hot supersonic jets. Mapping the nozzle velocity field using point based techniques requires over 60 hours of test time, compared to less than 45 minutes using DPIV, yielding a significant reduction in testing time. A dual camera DPIV configuration was used to maximize the field of view and further minimize the testing time required to map the nozzle flow. The DPIV system field of view covered 127 by 267 mm. Data were acquired at 19 axial stations providing coverage of the flow from the nozzle exit to 2.37 in downstream. At each measurement station, 400 image frame pairs were acquired from each camera. The DPIV measurements of the mixing enhanced nozzle designs illustrate the changes in the flow field resulting in the reduced noise signature.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-09-01
US DOE mixed low-level and mixed transuranic waste inventory was estimated at 181,000 cubic meters (about 2,000 waste streams). Treatability studies may be used as part of DOE`s mixed waste management program. Commercial treatability study suppliers have been identified that either have current capability in their own facilities or have access to licensed facilities. Numerous federal and state regulations, as well as DOE Order 5820.2A, impact the performance of treatability studies. Generators, transporters, and treatability study facilities are subject to regulation. From a mixed- waste standpoint, a key requirement is that the treatability study facility must have an NRC ormore » state license that allows it to possess radioactive materials. From a RCRA perspective, the facility must support treatability study activities with the applicable plans, reports, and documentation. If PCBs are present in the waste, TSCA will also be an issue. CERCLA requirements may apply, and both DOE and NRC regulations will impact the transportation of DOE mixed waste to an off-site treatment facility. DOE waste managers will need to be cognizant of all applicable regulations as mixed-waste treatability study programs are initiated.« less
Sawamura, Kensuke; Hashimoto, Masahiko
2017-01-01
A fluorescence quenching assay based on a ligase detection reaction was developed for facile and rapid detection of point mutations present in a mixed population of non-variant DNA. If the test DNA carried a targeted mutation, then the two allele-specific primers were ligated to form a molecular beacon resulting in the expected fluorescence quenching signatures. Using this method, we successfully detected as low as 5% mutant DNA in a mixture of wild-type DNA (t test at 99% confidence level).
Lewis Research Center's coal-fired, pressurized, fluidized-bed reactor test facility
NASA Astrophysics Data System (ADS)
Kobak, J. A.; Rollbuhler, R. J.
1981-10-01
A 200-kilowatt-thermal, pressurized, fluidized-bed (PFB) reactor, research test facility was designed, constructed, and operated as part of a NASA-funded project to assess and evaluate the effect of PFB hot-gas effluent on aircraft turbine engine materials that might have applications in stationary-power-plant turbogenerators. Some of the techniques and components developed for this PFB system are described. One of the more important items was the development of a two-in-one, gas-solids separator that removed 95+ percent of the solids in 1600 F to 1900 F gases. Another was a coal and sorbent feed and mixing system for injecting the fuel into the pressurized combustor. Also important were the controls and data-acquisition systems that enabled one person to operate the entire facility. The solid, liquid, and gas sub-systems all had problems that were solved over the 2-year operating time of the facility, which culminated in a 400-hour, hot-gas, turbine test.
Lewis Research Center's coal-fired, pressurized, fluidized-bed reactor test facility
NASA Technical Reports Server (NTRS)
Kobak, J. A.; Rollbuhler, R. J.
1981-01-01
A 200-kilowatt-thermal, pressurized, fluidized-bed (PFB) reactor, research test facility was designed, constructed, and operated as part of a NASA-funded project to assess and evaluate the effect of PFB hot-gas effluent on aircraft turbine engine materials that might have applications in stationary-power-plant turbogenerators. Some of the techniques and components developed for this PFB system are described. One of the more important items was the development of a two-in-one, gas-solids separator that removed 95+ percent of the solids in 1600 F to 1900 F gases. Another was a coal and sorbent feed and mixing system for injecting the fuel into the pressurized combustor. Also important were the controls and data-acquisition systems that enabled one person to operate the entire facility. The solid, liquid, and gas sub-systems all had problems that were solved over the 2-year operating time of the facility, which culminated in a 400-hour, hot-gas, turbine test.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hohne, Thomas; Kliem, Soren; Rohde, Ulrich
2006-07-01
Coolant mixing in the cold leg, downcomer and the lower plenum of pressurized water reactors is an important phenomenon mitigating the reactivity insertion into the core. Therefore, mixing of the de-borated slugs with the ambient coolant in the reactor pressure vessel was investigated at the four loop 1:5 scaled ROCOM mixing test facility. Thermal hydraulics analyses showed, that weakly borated condensate can accumulate in particular in the pump loop seal of those loops, which do not receive safety injection. After refilling of the primary circuit, natural circulation in the stagnant loops can re-establish simultaneously and the de-borated slugs are shiftedmore » towards the reactor pressure vessel (RPV). In the ROCOM experiments, the length of the flow ramp and the initial density difference between the slugs and the ambient coolant was varied. From the test matrix experiments with 0 resp. 2% density difference between the de-borated slugs and the ambient coolant were used to validate the CFD software ANSYS CFX. To model the effects of turbulence on the mean flow a higher order Reynolds stress turbulence model was employed and a mesh consisting of 6.4 million hybrid elements was utilized. Only the experiments and CFD calculations with modeled density differences show a stratification in the downcomer. Depending on the degree of density differences the less dense slugs flow around the core barrel at the top of the downcomer. At the opposite side the lower borated coolant is entrained by the colder safety injection water and transported to the core. The validation proves that ANSYS CFX is able to simulate appropriately the flow field and mixing effects of coolant with different densities. (authors)« less
NASA Astrophysics Data System (ADS)
Secondo, R.; Alía, R. Garcia; Peronnard, P.; Brugger, M.; Masi, A.; Danzeca, S.; Merlenghi, A.; Vaillé, J.-R.; Dusseau, L.
2017-08-01
A single event latchup (SEL) experiment based on commercial static random access memory (SRAM) memories has recently been proposed in the framework of the European Organization for Nuclear Research (CERN) Latchup Experiment and Student Satellite nanosatellite low Earth orbit (LEO) space mission. SEL characterization of three commercial SRAM memories has been carried out at the Paul Scherrer Institut (PSI) facility, using monoenergetic focused proton beams and different acquisition setups. The best target candidate was selected and a circuit for SEL detection has been proposed and tested at CERN, in the CERN High Energy AcceleRator Mixed-field facility (CHARM). Experimental results were carried out at test locations representative of the LEO environment, thus providing a full characterization of the SRAM cross sections, together with the analysis of the single-event effect and total ionizing dose of the latchup detection circuit in relation to the particle spectra expected during mission. The setups used for SEL monitoring are described, and details of the proposed circuit components and topology are presented. Experimental results obtained both at PSI and at CHARM facilities are discussed.
Liu, Chang; Feng, Zhanlian; Mor, Vincent
2014-02-01
To assess the association between ownership of Chinese elder care facilities and their performance quality and to compare the case-mix profile of residents and facility characteristics in government-owned and private-sector homes. Cross-sectional study. Census of elder care homes surveyed in Nanjing (2009) and Tianjin (2010). Elder care facilities located in urban Nanjing (n = 140, 95% of all) and urban Tianjin (n = 157, 97% of all). A summary case-mix index based on activity of daily living (ADL) limitations and cognitive impairment was created to measure levels of care needs of residents in each facility. Structure, process, and outcome measures were selected to assess facility-level quality of care. A structural quality measure, understaffing relative to resident levels of care needs, which indicates potentially inadequate staffing given resident case-mix, was also developed. Government-owned homes had significantly higher occupancy rates, presumably reflecting popular demand for publicly subsidized beds, but served residents who, on average, have fewer ADL and cognitive functioning limitations than those in private-sector facilities. Across a range of structure, process, and outcome measures of quality, there is no clear evidence suggesting advantages or disadvantages of either ownership type, although when staffing-to-resident ratio is gauged relative to resident case-mix, private-sector facilities were more likely to be understaffed than government-owned facilities. In Nanjing and Tianjin, private-sector homes were more likely to be understaffed, although their residents were sicker and frailer on average than those in government facilities. It is likely that the case-mix differences are the result of selective admission policies that favor healthier residents in government facilities than in private-sector homes. © 2014, Copyright the Authors Journal compilation © 2014, The American Geriatrics Society.
Life Cycle Cost Analysis of Ready Mix Concrete Plant
NASA Astrophysics Data System (ADS)
Topkar, V. M.; Duggar, A. R.; Kumar, A.; Bonde, P. P.; Girwalkar, R. S.; Gade, S. B.
2013-11-01
India, being a developing nation is experiencing major growth in its infrastructural sector. Concrete is the major component in construction. The requirement of good quality of concrete in large quantities can be fulfilled by ready mix concrete batching and mixing plants. The paper presents a technique of applying the value engineering tool life cycle cost analysis to a ready mix concrete plant. This will help an investor or an organization to take investment decisions regarding a ready mix concrete facility. No economic alternatives are compared in this study. A cost breakdown structure is prepared for the ready mix concrete plant. A market survey has been conducted to collect realistic costs for the ready mix concrete facility. The study establishes the cash flow for the ready mix concrete facility helpful in investment and capital generation related decisions. Transit mixers form an important component of the facility and are included in the calculations. A fleet size for transit mixers has been assumed for this purpose. The life cycle cost has been calculated for the system of the ready mix concrete plant and transit mixers.
The EPA is providing notice of a proposed Administrative Penalty Assessment against Iowa City Ready Mix, Inc., for alleged violations at a facility located at 1854 South Riverside, Iowa City, IA (“facility”). The facility produces and transports ready mixe
Brown, Samuel L
2002-01-01
To assess ownership-related differences in the Intermediate Care Facility Program for persons with Mental Retardation (ICF/MR) Industry, this article analyzes a nationally representative sample of data on Medicaid certified facilities from the Health Care Financing Administration On-line Survey and Certification Reporting System. This study found that nonprofit providers provided a higher level of quality than for-profit facilities when organizational size and facility-mix were controlled. The size and case-mix composition of these facilities were also influenced by nonprofit ownership type. Nonprofit providers offered smaller facilities, on average, and were more likely to enroll heavy case-mix residents than their for-profit counterparts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oden, L.L.; O`Conner, W.K.; Turner, P.C.
1993-11-19
This report presents field results and raw data from the Buried Waste Integrated Demonstration (BWID) Arc Melter Vitrification Project Phase 1 baseline test series conducted by the Idaho National Engineering Laboratory (INEL) in cooperation with the U.S. Bureau of Mines (USBM). The baseline test series was conducted using the electric arc melter facility at the USBM Albany Research Center in Albany, Oregon. Five different surrogate waste feed mixtures were tested that simulated thermally-oxidized, buried, TRU-contaminated, mixed wastes and soils present at the INEL. The USBM Arc Furnace Integrated Waste Processing Test Facility includes a continuous feed system, the arc meltingmore » furnace, an offgas control system, and utilities. The melter is a sealed, 3-phase alternating current (ac) furnace approximately 2 m high and 1.3 m wide. The furnace has a capacity of 1 metric ton of steel and can process as much as 1,500 lb/h of soil-type waste materials. The surrogate feed materials included five mixtures designed to simulate incinerated TRU-contaminated buried waste materials mixed with INEL soil. Process samples, melter system operations data and offgas composition data were obtained during the baseline tests to evaluate the melter performance and meet test objectives. Samples and data gathered during this program included (a) automatically and manually logged melter systems operations data, (b) process samples of slag, metal and fume solids, and (c) offgas composition, temperature, velocity, flowrate, moisture content, particulate loading and metals content. This report consists of 2 volumes: Volume I summarizes the baseline test operations. It includes an executive summary, system and facility description, review of the surrogate waste mixtures, and a description of the baseline test activities, measurements, and sample collection. Volume II contains the raw test data and sample analyses from samples collected during the baseline tests.« less
Li, Yue; Schnelle, John; Spector, William D; Glance, Laurent G; Mukamel, Dana B
2010-02-01
To assess the impact of facility case mix on cross-sectional variations and short-term stability of the "Nursing Home Compare" incontinence quality measure (QM) and to determine whether multivariate risk adjustment can minimize such impacts. Retrospective analyses of the 2005 national minimum data set (MDS) that included approximately 600,000 long-term care residents in over 10,000 facilities in each quarterly sample. Mixed logistic regression was used to construct the risk-adjusted QM (nonshrinkage estimator). Facility-level ordinary least-squares models and adjusted R(2) were used to estimate the impact of case mix on cross-sectional and short-term longitudinal variations of currently published and risk-adjusted QMs. At least 50 percent of the cross-sectional variation and 25 percent of the short-term longitudinal variation of the published QM are explained by facility case mix. In contrast, the cross-sectional and short-term longitudinal variations of the risk-adjusted QM are much less susceptible to case-mix variations (adjusted R(2)<0.10), even for facilities with more extreme or more unstable outcome. Current "Nursing Home Compare" incontinence QM reflects considerable case-mix variations across facilities and over time, and therefore it may be biased. This issue can be largely addressed by multivariate risk adjustment using risk factors available in the MDS.
Liu, Chang
2015-01-01
Objective To assess the association between ownership of Chinese elder care facilities and their performance quality; and to compare the case-mix profile of residents and facility characteristics in government-owned and private-sector homes. Design Cross-sectional study. Setting Census of elder care homes surveyed in Nanjing (in 2009) and Tianjin (in 2010). Population 140 (or 95% of all) elder care facilities located in urban Nanjing, and 157 (or 97% of all) facilities in urban Tianjin. Main study outcome measures We created a summary case-mix index based on activities of daily living (ADL) limitations and cognitive impairment to measure levels of care needs among residents in each facility. We selected structure, process, and outcome measures to assess facility-level quality of care. We also developed a structural quality measure, under-staffing relative to residents’ levels of care needs, which indicates potentially inadequate staffing given the residents’ case-mix. Results Government-owned homes have significantly higher occupancy rates, presumably reflecting popular demand for publicly subsidized beds, but they serve residents who, on average, have fewer ADL and cognitive functioning limitations than do private-sector facilities. Across a range of structure, process, and outcome measures of quality, there is no clear evidence suggesting advantages or disadvantages to either ownership type. However, when staffing to resident ratio is gauged relative to residents’ case-mix, private-sector facilities were more likely to be under-staffed than government-owned facilities. Conclusions In Nanjing and Tianjin, private-sector homes were more likely to be understaffed, although their residents were sicker and frailer, on average, than those in government facilities. The case-mix differences are likely the result of selective admission policies that favor relatively healthier residents in government facilities than in private-sector homes. PMID:24433350
2016-08-01
ice have catastrophic effects on facilities, infrastructure, and military testing and training. Permafrost temperature , thickness, and geographic...treeline) and fire severity (~0 to ~100% SOL consumption ), they provide an excellent suite of sites to test and quantify the effects of fire severity...stages .........................59 Table 6.1. Variables included in explanatory matrix for black spruce dominance ............68 Table 6.2. Mixed effect
2016-08-01
catastrophic effects on facilities, infrastructure, and military testing and training. Permafrost temperature , thickness, and geographic continuity...and fire severity (~0 to ~100% SOL consumption ), they provide an excellent suite of sites to test and quantify the effects of fire severity on plant...59 Table 6.1. Variables included in explanatory matrix for black spruce dominance ............68 Table 6.2. Mixed effect model
Iowa City Ready Mix, Inc. - Clean Water Act Public Notice
The EPA is providing notice of a proposed Administrative Penalty Assessment against Iowa City Ready Mix, Inc., for alleged violations at a facility located at 1854 South Riverside, Iowa City, IA (“facility”). The facility produces and transports ready mixe
Novel and facile viscometer using a paper-based microfluidic device
NASA Astrophysics Data System (ADS)
Kang, Hyunwoong; Jang, Ilhoon; Song, Simon
2017-11-01
In clinical applications, it is important to rapidly estimate the blood viscosity of a patient with a high accuracy and a small sample consumption. Unfortunately, ordinary mechanical viscometers require long analysis time, large volume of sample and skilled person. To address this issue, silicon-based viscometers have been developed, but they are still far from prevail usage in clinical environments due to complexity in process and analysis. Recently, a paper-based microfluidic device is emerged as a new platform for a facile point-of-care diagnostic device due to low cost, disposability and ease of use. Thus, we propose a novel and facile method of measuring a viscosity with a paper-based microfluidic devices and a smartphone. This viscometer utilizes mixing characteristics of two fluid flows in a T-shape channel: one for reference and the other for test fluid. The mixing strongly depends on viscosity difference between the two fluids. Also, the fluids are dyed for colorimetric analysis with a smartphone. We found that the accuracy of viscometer is about 3 percent when it was tested for various glycerin aqueous solutions. More detailed information will be discussed in the presentation. This work was supported by the National Research Foundation of Korea(NRF) Grant funded by the Korea government(MSIP) (No. 2016R1A2B3009541).
The marketing mix and development of medical tourism in shiraz.
Jabbari, Alireza; Rahimi Zarchi, Mohammad Kazem; Kavosi, Zahra; Shafaghat, Tahere; Keshtkaran, Ali
2013-01-01
In recent years, medical tourism market has been raised as one of the income-earning and competitive industries in the world and is considered as a modern field of advanced tourism. Therefore, a great number of countries are seeking to develop this type of tourism and one of the strategies for developing this industry is using the marketing mix elements. This study was a descriptive-analytic and cross sectional one. The research community included all the public and private hospitals of Shiraz among which, 7 public and 9 private hospitals were studied. The study data were collected through a researcher-made check list whose face and content validity was confirmed by the experts. Then, the data were entered into the SPSS statistical software. According to the objectives of the study, the descriptive results were presented in frequency tables and Chi-square test was used for data analysis. In addition, P<0.05 was considered as statistically significant. According to the results, both public and private hospitals of Shiraz were in the best condition regarding staff and physician mix and in the worst condition concerning promoting and facilities mixes. No significant difference was found between public and private hospitals regarding the mixes. From marketing mix elements view, paying more attention to media advertisements and providing more facilities can improve the status of the hospitals which, consequently, results in attracting more medical tourists and developing this industry in Shiraz.
Kreider, Marisa L; Cyrs, William D; Tosiano, Melissa A; Panko, Julie M
2015-11-01
Current recommendations for nanomaterial-specific exposure assessment require adaptation in order to be applied to complicated manufacturing settings, where a variety of particle types may contribute to the potential exposure. The purpose of this work was to evaluate a method that would allow for exposure assessment of nanostructured materials by chemical composition and size in a mixed dust setting, using carbon black (CB) and amorphous silica (AS) from tire manufacturing as an example. This method combined air sampling with a low pressure cascade impactor with analysis of elemental composition by size to quantitatively assess potential exposures in the workplace. This method was first pilot-tested in one tire manufacturing facility; air samples were collected with a Dekati Low Pressure Impactor (DLPI) during mixing where either CB or AS were used as the primary filler. Air samples were analyzed via scanning transmission electron microscopy (STEM) coupled with energy dispersive spectroscopy (EDS) to identify what fraction of particles were CB, AS, or 'other'. From this pilot study, it was determined that ~95% of all nanoscale particles were identified as CB or AS. Subsequent samples were collected with the Dekati Electrical Low Pressure Impactor (ELPI) at two tire manufacturing facilities and analyzed using the same methodology to quantify exposure to these materials. This analysis confirmed that CB and AS were the predominant nanoscale particle types in the mixing area at both facilities. Air concentrations of CB and AS ranged from ~8900 to 77600 and 400 to 22200 particles cm(-3), respectively. This method offers the potential to provide quantitative estimates of worker exposure to nanoparticles of specific materials in a mixed dust environment. With pending development of occupational exposure limits for nanomaterials, this methodology will allow occupational health and safety practitioners to estimate worker exposures to specific materials, even in scenarios where many particle types are present. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-21
...The U.S. Nuclear Regulatory Commission (NRC or Commission) is issuing a revision to regulatory guide (RG) 3.39, ``Standard Format and Content of License Applications for Mixed Oxide Fuel Fabrication Facilities.'' This guide endorses the standard format and content for license applications and integrated safety analysis (ISA) summaries described in the current version of NUREG-1718, ``Standard Review Plan for the Review of an Application for a Mixed Oxide (MOX) Fuel Fabrication Facility,'' as a method that the NRC staff finds acceptable for meeting the regulatory requirements of Title 10 of the Code of Federal Regulations (10 CFR) part 70, ``Domestic Licensing of Special Nuclear Material'' for mixed oxide fuel fabrication facilities.
Preliminary hazards analysis -- vitrification process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coordes, D.; Ruggieri, M.; Russell, J.
1994-06-01
This paper presents a Preliminary Hazards Analysis (PHA) for mixed waste vitrification by joule heating. The purpose of performing a PHA is to establish an initial hazard categorization for a DOE nuclear facility and to identify those processes and structures which may have an impact on or be important to safety. The PHA is typically performed during and provides input to project conceptual design. The PHA is then followed by a Preliminary Safety Analysis Report (PSAR) performed during Title 1 and 2 design. The PSAR then leads to performance of the Final Safety Analysis Report performed during the facility`s constructionmore » and testing. It should be completed before routine operation of the facility commences. This PHA addresses the first four chapters of the safety analysis process, in accordance with the requirements of DOE Safety Guidelines in SG 830.110. The hazards associated with vitrification processes are evaluated using standard safety analysis methods which include: identification of credible potential hazardous energy sources; identification of preventative features of the facility or system; identification of mitigative features; and analyses of credible hazards. Maximal facility inventories of radioactive and hazardous materials are postulated to evaluate worst case accident consequences. These inventories were based on DOE-STD-1027-92 guidance and the surrogate waste streams defined by Mayberry, et al. Radiological assessments indicate that a facility, depending on the radioactive material inventory, may be an exempt, Category 3, or Category 2 facility. The calculated impacts would result in no significant impact to offsite personnel or the environment. Hazardous materials assessment indicates that a Mixed Waste Vitrification facility will be a Low Hazard facility having minimal impacts to offsite personnel and the environment.« less
Properties important to mixing and simulant recommendations for WTP full-scale vessel testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poirier, M. R.; Martino, C. J.
2015-12-01
Full Scale Vessel Testing (FSVT) is being planned by Bechtel National, Inc., to demonstrate the ability of the standard high solids vessel design (SHSVD) to meet mixing requirements over the range of fluid properties planned for processing in the Pretreatment Facility (PTF) of the Hanford Waste Treatment and Immobilization Plant (WTP). Testing will use simulated waste rather than actual Hanford waste. Therefore, the use of suitable simulants is critical to achieving the goals of the test program. WTP personnel requested the Savannah River National Laboratory (SRNL) to assist with development of simulants for use in FSVT. Among the tasks assignedmore » to SRNL was to develop a list of waste properties that are important to pulse-jet mixer (PJM) performance in WTP vessels with elevated concentrations of solids.« less
NASA Technical Reports Server (NTRS)
Norum, T. D.
1978-01-01
A 2.54 cm (1.00 in.) nozzle supplied with nitrogen was mounted above an automobile and driven over an asphalt roadway past stationary microphones in an attempt to quantify the effects of the vehicle motion on jet mixing noise. The nozzle was then tested in the Langley anechoic noise facility with a large free jet simulating the relative motion. The results are compared for these two methods of investigating forward speed effects on jet mixing noise. The vehicle results indicate a noise with forward speed throughout the Doppler-shifted static spectrum. This decrease across the entire frequency range was also apparent in the free-jet results. The similarity of the results indicates that the effects of flight on jet mixing noise can be predicted by simulation of forward speed with a free jet. Overall sound pressure levels were found to decrease with forward speed at all observation angles for both methods of testing.
Update on the NASA Glenn Propulsion Systems Lab Ice Crystal Cloud Characterization (2015, 2016)
NASA Technical Reports Server (NTRS)
Van Zante, Judith; Bencic, Timothy; Ratvasky, Thomas
2016-01-01
NASA Glenn's Propulsion Systems Lab, an altitude engine test facility, was outfitted with a spray system to generate ice crystals in 2011. Turbine engines and driven rigs can experience ice crystal icing at flight altitudes, temperatures and Mach numbers. To support these tests, four ice crystal characterizations have been conducted in two different facility configurations. In addition, super-cooled liquid and mixed phase clouds have also been generated. This paper represents a work in progress. It will describe some of the 11-parameter calibration space, and how those parameters interact with each other, the instrumentation used to characterize the cloud and present a sample of the cloud characterization results.
Ice Accretion Measurements on an Airfoil and Wedge in Mixed-Phase Conditions
NASA Technical Reports Server (NTRS)
Struk, Peter; Bartkus, Tadas; Tsao, Jen-Ching; Currie, Tom; Fuleki, Dan
2015-01-01
This paper describes ice accretion measurements from experiments conducted at the National Research Council (NRC) of Canada's Research Altitude Test Facility during 2012. Due to numerous engine power loss events associated with high altitude convective weather, potential ice accretion within an engine due to ice crystal ingestion is being investigated collaboratively by NASA and NRC. These investigations examine the physical mechanisms of ice accretion on surfaces exposed to ice crystal and mixed phase conditions, similar to those believed to exist in core compressor regions of jet engines. A further objective of these tests is to examine scaling effects since altitude appears to play a key role in this icing process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paladino, D.; Guentay, S.; Andreani, M.
2012-07-01
During a postulated severe accident with core degradation, hydrogen would form in the reactor pressure vessel mainly due to high temperatures zirconium-steam reaction and flow together with steam into the containment where it will mix with the containment atmosphere (steam-air). The hydrogen transport into the containment is a safety concern because it can lead to explosive mixtures through the associated phenomena of condensation, mixing and stratification. The ERCOSAM and SAMARA projects, co-financed by the European Union and the Russia, include various experiments addressing accident scenarios scaled down from existing plant calculations to different thermal-hydraulics facilities (TOSQAN, MISTRA, PANDA, SPOT). Themore » tests sequences aim to investigate hydrogen concentration build-up and stratification during a postulated accident and the effect of the activation of Severe Accident Management systems (SAMs), e.g. sprays, coolers and Passive Auto-catalytic Recombiners (PARs). Analytical activities, performed by the project participants, are an essential component of the projects, as they aim to improve and validate various computational methods. They accompany the projects in the various phases; plant calculations, scaling to generic containment and to the different facilities, planning pre-test and post-test simulations are performed. Code benchmark activities on the basis of conceptual near full scale HYMIX facility will finally provide a further opportunity to evaluate the applicability of the various methods to the study of scaling issues. (authors)« less
Restructuring in response to case mix reimbursement in nursing homes: A contingency approach
Zinn, Jacqueline; Feng, Zhanlian; Mor, Vincent; Intrator, Orna; Grabowski, David
2013-01-01
Background Resident-based case mix reimbursement has become the dominant mechanism for publicly funded nursing home care. In 1998 skilled nursing facility reimbursement changed from cost-based to case mix adjusted payments under the Medicare Prospective Payment System for the costs of all skilled nursing facility care provided to Medicare recipients. In addition, as of 2004, 35 state Medicaid programs had implemented some form of case mix reimbursement. Purpose The purpose of the study is to determine if the implementation of Medicare and Medicaid case mix reimbursement increased the administrative burden on nursing homes, as evidenced by increased levels of nurses in administrative functions. Methodology/Approach The primary data for this study come from the Centers for Medicare and Medicaid Services Online Survey Certification and Reporting database from 1997 through 2004, a national nursing home database containing aggregated facility-level information, including staffing, organizational characteristics and resident conditions, on all Medicare/Medicaid certified nursing facilities in the country. We conducted multivariate regression analyses using a facility fixed-effects model to examine the effects of the implementation of Medicaid case mix reimbursement and Medicare Prospective Payment System on changes in the level of total administrative nurse staffing in nursing homes. Findings Both Medicaid case mix reimbursement and Medicare Prospective Payment System increased the level of administrative nurse staffing, on average by 5.5% and 4.0% respectively. However, lack of evidence for a substitution effect suggests that any decline in direct care staffing after the introduction of case mix reimbursement is not attributable to a shift from clinical nursing resources to administrative functions. Practice Implications Our findings indicate that the administrative burden posed by case mix reimbursement has resource implications for all freestanding facilities. At the margin, the increased administrative burden imposed by case mix may become a factor influencing a range of decisions, including resident admission and staff hiring. PMID:18360162
Restructuring in response to case mix reimbursement in nursing homes: a contingency approach.
Zinn, Jacqueline; Feng, Zhanlian; Mor, Vincent; Intrator, Orna; Grabowski, David
2008-01-01
Resident-based case mix reimbursement has become the dominant mechanism for publicly funded nursing home care. In 1998 skilled nursing facility reimbursement changed from cost-based to case mix adjusted payments under the Medicare Prospective Payment System for the costs of all skilled nursing facility care provided to Medicare recipients. In addition, as of 2004, 35 state Medicaid programs had implemented some form of case mix reimbursement. The purpose of the study is to determine if the implementation of Medicare and Medicaid case mix reimbursement increased the administrative burden on nursing homes, as evidenced by increased levels of nurses in administrative functions. The primary data for this study come from the Centers for Medicare and Medicaid Services Online Survey Certification and Reporting database from 1997 through 2004, a national nursing home database containing aggregated facility-level information, including staffing, organizational characteristics and resident conditions, on all Medicare/Medicaid certified nursing facilities in the country. We conducted multivariate regression analyses using a facility fixed-effects model to examine the effects of the implementation of Medicaid case mix reimbursement and Medicare Prospective Payment System on changes in the level of total administrative nurse staffing in nursing homes. Both Medicaid case mix reimbursement and Medicare Prospective Payment System increased the level of administrative nurse staffing, on average by 5.5% and 4.0% respectively. However, lack of evidence for a substitution effect suggests that any decline in direct care staffing after the introduction of case mix reimbursement is not attributable to a shift from clinical nursing resources to administrative functions. Our findings indicate that the administrative burden posed by case mix reimbursement has resource implications for all freestanding facilities. At the margin, the increased administrative burden imposed by case mix may become a factor influencing a range of decisions, including resident admission and staff hiring.
NASA Johnson Space Center Usability Testing and Analysis Facility (UTAF) Overview
NASA Technical Reports Server (NTRS)
Whitmore, M.
2004-01-01
The Usability Testing and Analysis Facility (UTAF) is part of the Space Human Factors Laboratory at the NASA Johnson Space Center in Houston, Texas. The facility provides support to the Office of Biological and Physical Research, the Space Shuttle Program, the International Space Station Program, and other NASA organizations. In addition, there are ongoing collaborative research efforts with external businesses and universities. The UTAF provides human factors analysis, evaluation, and usability testing of crew interfaces for space applications. This includes computer displays and controls, workstation systems, and work environments. The UTAF has a unique mix of capabilities, with a staff experienced in both cognitive human factors and ergonomics. The current areas of focus are: human factors applications in emergency medical care and informatics; control and display technologies for electronic procedures and instructions; voice recognition in noisy environments; crew restraint design for unique microgravity workstations; and refinement of human factors processes. This presentation will provide an overview of ongoing activities, and will address how the projects will evolve to meet new space initiatives.
NASA Johnson Space Center Usability Testing and Analysis Facility (WAF) Overview
NASA Technical Reports Server (NTRS)
Whitmore, M.
2004-01-01
The Usability Testing and Analysis Facility (UTAF) is part of the Space Human Factors Laboratory at the NASA Johnson Space Center in Houston, Texas. The facility provides support to the Office of Biological and Physical Research, the Space Shuttle Program, the International Space Station Program, and other NASA organizations. In addition, there are ongoing collaborative research efforts with external businesses and universities. The UTAF provides human factors analysis, evaluation, and usability testing of crew interfaces for space applications. This includes computer displays and controls, workstation systems, and work environments. The UTAF has a unique mix of capabilities, with a staff experienced in both cognitive human factors and ergonomics. The current areas of focus are: human factors applications in emergency medical care and informatics; control and display technologies for electronic procedures and instructions; voice recognition in noisy environments; crew restraint design for unique microgravity workstations; and refinement of human factors processes. This presentation will provide an overview of ongoing activities, and will address how the projects will evolve to meet new space initiatives.
Update on the NASA Glenn Propulsion Systems Lab Ice Crystal Cloud Characterization (2015)
NASA Technical Reports Server (NTRS)
Van Zante, Judith F.; Bencic, Timothy J.; Ratvasky, Thomas P.
2016-01-01
NASA Glenn's Propulsion Systems Lab (PSL), an altitude engine test facility, was outfitted with a spray system to generate ice crystals. The first ice crystal characterization test occurred in 2012. At PSL, turbine engines and driven rigs can experience ice crystal icing at flight altitudes, temperatures and Mach numbers. To support these tests, four ice crystal characterizations have been conducted in two different facility configurations. In addition, super-cooled liquid and mixed phase clouds have also been generated. This paper will discuss the recent learning from the previous two calibrations. It will describe some of the 12-parameter calibration space, and how those parameters interact with each other, the instrumentation used to characterize the cloud and present a sample of the cloud characterization results.
Cheng, Weizhi; Roessler, Justin; Blaisi, Nawaf I; Townsend, Timothy G
2014-12-01
Drinking water treatment residues (WTR) offer potential benefits when recycled through land application. The current guidance in Florida, US allows for unrestricted land application of lime softening WTR; alum and ferric WTR require additional evaluation of total and leachable concentrations of select trace metals prior to land application. In some cases a mixed WTR is produced when lime softening is accompanied by the addition of a coagulant or other treatment chemical; applicability of the current guidance is unclear. The objective of this research was to characterize the total and leachable chemical content of WTR from Florida facilities that utilize multiple treatment chemicals. Lime and mixed lime WTR samples were collected from 18 water treatment facilities in Florida. Total and leachable concentrations of the WTR were measured. To assess the potential for disposal of mixed WTR as clean fill below the water table, leaching tests were conducted at multiple liquid to solid ratios and under reducing conditions. The results were compared to risk-based soil and groundwater contamination thresholds. Total metal concentrations of WTR were found to be below Florida soil contaminant thresholds with Fe found in the highest abundance at a concentration of 3600 mg/kg-dry. Aluminum was the only element that exceeded the Florida groundwater contaminant thresholds using SPLP (95% UCL = 0.23 mg/L; risk threshold = 0.2 mg/L). Tests under reducing conditions showed elevated concentrations of Fe and Mn, ranging from 1 to 3 orders of magnitude higher than SPLP leachates. Mixed lime WTR concentrations (total and leachable) were lower than the ferric and alum WTR concentrations, supporting that mixed WTR are appropriately represented as lime WTR. Testing of WTR under reducing conditions demonstrated the potential for release of certain trace metals (Fe, Al, Mn) above applicable regulatory thresholds; additional evaluation is needed to assess management options where reducing conditions may develop. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Struk, Peter; Tsao, Jen-Ching; Bartkus, Tadas
2017-01-01
This paper describes plans and preliminary results for using the NASA Propulsion Systems Lab (PSL) to experimentally study the fundamental physics of ice-crystal ice accretion. NASA is evaluating whether this facility, in addition to full-engine and motor-driven-rig tests, can be used for more fundamental ice-accretion studies that simulate the different mixed-phase icing conditions along the core flow passage of a turbo-fan engine compressor. The data from such fundamental accretion tests will be used to help develop and validate models of the accretion process. This paper presents data from some preliminary testing performed in May 2015 which examined how a mixed-phase cloud could be generated at PSL using evaporative cooling in a warmer-than-freezing environment.
Effect of prospective reimbursement on nursing home costs.
Coburn, A F; Fortinsky, R; McGuire, C; McDonald, T P
1993-01-01
OBJECTIVE. This study evaluates the effect of Maine's Medicaid nursing home prospective payment system on nursing home costs and access to care for public patients. DATA SOURCES/STUDY SETTING. The implementation of a facility-specific prospective payment system for nursing homes provided the opportunity for longitudinal study of the effect of that system. Data sources included audited Medicaid nursing home cost reports, quality-of-care data from state facility survey and licensure files, and facility case-mix information from random, stratified samples of homes and residents. Data were obtained for six years (1979-1985) covering the three-year period before and after implementation of the prospective payment system. STUDY DESIGN. This study used a pre-post, longitudinal analytical design in which interrupted, time-series regression models were estimated to test the effects of prospective payment and other factors, e.g., facility characteristics, nursing home market factors, facility case mix, and quality of care, on nursing home costs. PRINCIPAL FINDINGS. Prospective payment contributed to an estimated $3.03 decrease in total variable costs in the third year from what would have been expected under the previous retrospective cost-based payment system. Responsiveness to payment system efficiency incentives declined over the study period, however, indicating a growing problem in achieving further cost reductions. Some evidence suggested that cost reductions might have reduced access for public patients. CONCLUSIONS. Study findings are consistent with the results of other studies that have demonstrated the effectiveness of prospective payment systems in restraining nursing home costs. Potential policy trade-offs among cost containment, access, and quality assurance deserve further consideration, particularly by researchers and policymakers designing the new generation of case mix-based and other nursing home payment systems. PMID:8463109
Effect of prospective reimbursement on nursing home costs.
Coburn, A F; Fortinsky, R; McGuire, C; McDonald, T P
1993-04-01
This study evaluates the effect of Maine's Medicaid nursing home prospective payment system on nursing home costs and access to care for public patients. The implementation of a facility-specific prospective payment system for nursing homes provided the opportunity for longitudinal study of the effect of that system. Data sources included audited Medicaid nursing home cost reports, quality-of-care data from state facility survey and licensure files, and facility case-mix information from random, stratified samples of homes and residents. Data were obtained for six years (1979-1985) covering the three-year period before and after implementation of the prospective payment system. This study used a pre-post, longitudinal analytical design in which interrupted, time-series regression models were estimated to test the effects of prospective payment and other factors, e.g., facility characteristics, nursing home market factors, facility case mix, and quality of care, on nursing home costs. Prospective payment contributed to an estimated $3.03 decrease in total variable costs in the third year from what would have been expected under the previous retrospective cost-based payment system. Responsiveness to payment system efficiency incentives declined over the study period, however, indicating a growing problem in achieving further cost reductions. Some evidence suggested that cost reductions might have reduced access for public patients. Study findings are consistent with the results of other studies that have demonstrated the effectiveness of prospective payment systems in restraining nursing home costs. Potential policy trade-offs among cost containment, access, and quality assurance deserve further consideration, particularly by researchers and policymakers designing the new generation of case mix-based and other nursing home payment systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thien, Mike G.; Barnes, Steve M.
2013-07-01
The Hanford Tank Operations Contractor (TOC) and the Hanford Waste Treatment and Immobilization Plant (WTP) contractor are both engaged in demonstrating mixing, sampling, and transfer system capabilities using simulated Hanford High-Level Waste (HLW) formulations. This represents one of the largest remaining technical issues with the high-level waste treatment mission at Hanford. Previous testing has focused on very specific TOC or WTP test objectives and consequently the simulants were narrowly focused on those test needs. A key attribute in the Defense Nuclear Facilities Safety Board (DNFSB) Recommendation 2010-2 is to ensure testing is performed with a simulant that represents the broadmore » spectrum of Hanford waste. The One System Integrated Project Team is a new joint TOC and WTP organization intended to ensure technical integration of specific TOC and WTP systems and testing. A new approach to simulant definition has been mutually developed that will meet both TOC and WTP test objectives for the delivery and receipt of HLW. The process used to identify critical simulant characteristics, incorporate lessons learned from previous testing, and identify specific simulant targets that ensure TOC and WTP testing addresses the broad spectrum of Hanford waste characteristics that are important to mixing, sampling, and transfer performance are described. (authors)« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-28
... Safety Board, Pulse Jet Mixing at the Waste Treatment and Immobilization Plant AGENCY: Department of... their Recommendation 2010-2, concerning Pulse Jet Mixing at the Waste Treatment and Immobilization Plant... Nuclear Facilities Safety Board (Board) Recommendation 2010-2, Pulse Jet Mixing (PJM) at the Waste...
The Marketing Mix and Development of Medical Tourism in Shiraz
Jabbari, Alireza; Rahimi Zarchi, Mohammad Kazem; Kavosi, Zahra; Shafaghat, Tahere; Keshtkaran, Ali
2013-01-01
Introduction: In recent years, medical tourism market has been raised as one of the income-earning and competitive industries in the world and is considered as a modern field of advanced tourism. Therefore, a great number of countries are seeking to develop this type of tourism and one of the strategies for developing this industry is using the marketing mix elements. Methods: This study was a descriptive-analytic and cross sectional one. The research community included all the public and private hospitals of Shiraz among which, 7 public and 9 private hospitals were studied. The study data were collected through a researcher-made check list whose face and content validity was confirmed by the experts. Then, the data were entered into the SPSS statistical software. According to the objectives of the study, the descriptive results were presented in frequency tables and Chi-square test was used for data analysis. In addition, P<0.05 was considered as statistically significant. Results: According to the results, both public and private hospitals of Shiraz were in the best condition regarding staff and physician mix and in the worst condition concerning promoting and facilities mixes. No significant difference was found between public and private hospitals regarding the mixes. Conclusion: From marketing mix elements view, paying more attention to media advertisements and providing more facilities can improve the status of the hospitals which, consequently, results in attracting more medical tourists and developing this industry in Shiraz. PMID:23678337
NASA Technical Reports Server (NTRS)
Bryan, William B.; Fleeter, Sanford
1987-01-01
The internal three-dimensional steady and time-varying flow through the diffusing elements of a centrifugal impeller were investigated using a moderate scale, subsonic, mixed flow research compressor facility. The characteristics of the test facility which permit the measurement of internal flow conditions throughout the entire research compressor and radial diffuser for various operating conditions are described. Results are presented in the form of graphs and charts to cover a range of mass flow rates with inlet guide vane settings varying from minus 15 degrees to plus 45 degrees. The static pressure distributions in the compressor inlet section and on the impeller and exit diffuser vanes, as well as the overall pressure and temperature rise and mass flow rate, were measured and analyzed at each operating point to determine the overall performance as well as the detailed aerodynamics throughout the compressor.
Ratnayake, Ruwan; Ho, Lara S; Ansumana, Rashid; Brown, Hannah; Borchert, Matthias; Miller, Laura; Kratz, Thomas; McMahon, Shannon A; Sahr, Foday
2016-01-01
Accomplishing infection prevention and control (IPC) in health facilities in Sub-Saharan Africa is challenging. Owing to poor IPC, healthcare workers (HCWs) were frequently infected during Sierra Leone's Ebola epidemic. In late 2014, IPC was rapidly and nationally scaled up. We carried out workshops in sampled facilities to further improve adherence to IPC. We investigated HCW experiences and observed practice gaps, before and after the workshops. We conducted an uncontrolled, before and after, mixed-methods study in eight health facilities in Bo and Kenema Districts during December 2014 and January 2015. Quantitative methods administered to HCWs at baseline and follow-up included a survey on attitudes and self-efficacy towards IPC, and structured observations of behaviours. The intervention involved a workshop for HCWs to develop improvement plans for their facility. We analysed the changes between rounds in survey responses and behaviours. We used interviews to explore attitudes and self-efficacy throughout the study period. HCWs described IPC as 'life-saving' and personal protective equipment (PPE) as uncomfortable for providers and frightening for patients. At baseline, self-efficacy was high (median=4/strongly agree). Responses reflecting unfavourable attitudes were low for glove use (median=1/strongly disagree, IQR, 1-2) and PPE use with ill family members (median=1, IQR, 1-2), and mixed for PPE use with ill HCWs (median=2/disagree, IQR, 1-4). Observations demonstrated consistent glove reuse and poor HCW handwashing. The maintenance of distance (RR 1.09, 95% CI 1.02 to 1.16) and patient handwashing (RR 1.19, 95% CI 1.3 to 1.25) improved to >90%. We found favourable attitudes towards IPC and gaps in practice. Risk perceptions of HCWs and tendencies to ration PPE where chronic supply chain issues normally lead to PPE stock-outs may affect practice. As Sierra Leone's Ebola Recovery Strategy aims to make all facilities IPC compliant, socio-behavioural improvements and a secure supply chain are essential.
Mixed Oxide Fresh Fuel Package Auxiliary Equipment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yapuncich, F.; Ross, A.; Clark, R.H.
2008-07-01
The United States Department of Energy's National Nuclear Security Administration (NNSA) is overseeing the construction the Mixed Oxide (MOX) Fuel Fabrication Facility (MFFF) on the Savannah River Site. The new facility, being constructed by NNSA's contractor Shaw AREVA MOX Services, will fabricate fuel assemblies utilizing surplus plutonium as feedstock. The fuel will be used in designated commercial nuclear reactors. The MOX Fresh Fuel Package (MFFP), which has recently been licensed by the Nuclear Regulatory Commission (NRC) as a type B package (USA/9295/B(U)F-96), will be utilized to transport the fabricated fuel assemblies from the MFFF to the nuclear reactors. It wasmore » necessary to develop auxiliary equipment that would be able to efficiently handle the high precision fuel assemblies. Also, the physical constraints of the MFFF and the nuclear power plants require that the equipment be capable of loading and unloading the fuel assemblies both vertically and horizontally. The ability to reconfigure the load/unload evolution builds in a large degree of flexibility for the MFFP for the handling of many types of both fuel and non fuel payloads. The design and analysis met various technical specifications including dynamic and static seismic criteria. The fabrication was completed by three major fabrication facilities within the United States. The testing was conducted by Sandia National Laboratories. The unique design specifications and successful testing sequences will be discussed. (authors)« less
The Impact of School Facilities on the Learning Environment
ERIC Educational Resources Information Center
Vandiver, Bert
2011-01-01
The purpose of this mixed methods study was to examine the impact of the quality of facilities on the educational environment in high schools located in northeast Texas. The intent of this research study was to determine the relationship between school facilities and the school-learning environment. This study was a mixed method research that used…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-11
... Safety Board, Pulse Jet Mixing at the Waste Treatment and Immobilization Plant AGENCY: Department of..., concerning Pulse Jet Mixing at the Waste Treatment and Immobilization Plant was published in the Federal... Defense Nuclear Facilities Safety Board (Board) Recommendation 2010-2, Pulse Jet Mixing at the Waste...
2000-03-01
26 Leachate Pathway.................................... 31 Plant Uptake Pathway.................................. 35 Volatization and Odor...Bi13 Appendix C - Surface Runoff Testing............................Cl Appendix D - Leachate Evaluation..............................D1 Appendix E...Oxidized Dredged Material..........................29 Table 7. Mixing Zone Requirement for Runoff Discharges............ 30 Table 8. Leachate Quality
NASA Technical Reports Server (NTRS)
Allgood, Daniel C.; Graham, Jason S.; Ahuja, Vineet; Hosangadi, Ashvin
2008-01-01
Simulation technology can play an important role in rocket engine test facility design and development by assessing risks, providing analysis of dynamic pressure and thermal loads, identifying failure modes and predicting anomalous behavior of critical systems. Advanced numerical tools assume greater significance in supporting testing and design of high altitude testing facilities and plume induced testing environments of high thrust engines because of the greater inter-dependence and synergy in the functioning of the different sub-systems. This is especially true for facilities such as the proposed A-3 facility at NASA SSC because of a challenging operating envelope linked to variable throttle conditions at relatively low chamber pressures. Facility designs in this case will require a complex network of diffuser ducts, steam ejector trains, fast operating valves, cooling water systems and flow diverters that need to be characterized for steady state performance. In this paper, we will demonstrate with the use of CFD analyses s advanced capability to evaluate supersonic diffuser and steam ejector performance in a sub-scale A-3 facility at NASA Stennis Space Center (SSC) where extensive testing was performed. Furthermore, the focus in this paper relates to modeling of critical sub-systems and components used in facilities such as the A-3 facility. The work here will address deficiencies in empirical models and current CFD analyses that are used for design of supersonic diffusers/turning vanes/ejectors as well as analyses for confined plumes and venting processes. The primary areas that will be addressed are: (1) supersonic diffuser performance including analyses of thermal loads (2) accurate shock capturing in the diffuser duct; (3) effect of turning duct on the performance of the facility (4) prediction of mass flow rates and performance classification for steam ejectors (5) comparisons with test data from sub-scale diffuser testing and assessment of confidence levels in CFD based flowpath modeling of the facility. The analyses tools used here expand on the multi-element unstructured CFD which has been tailored and validated for impingement dynamics of dry plumes, complex valve/feed systems, and high pressure propellant delivery systems used in engine and component test stands at NASA SSC. The analyses performed in the evaluation of the sub-scale diffuser facility explored several important factors that influence modeling and understanding of facility operation such as (a) importance of modeling the facility with Real Gas approximation, (b) approximating the cluster of steam ejector nozzles as a single annular nozzle, (c) existence of mixed subsonic/supersonic flow downstream of the turning duct, and (d) inadequacy of two-equation turbulence models in predicting the correct pressurization in the turning duct and expansion of the second stage steam ejectors. The procedure used for modeling the facility was as follows: (i) The engine, test cell and first stage ejectors were simulated with an axisymmetric approximation (ii) the turning duct, second stage ejectors and the piping downstream of the second stage ejectors were analyzed with a three-dimensional simulation utilizing a half-plane symmetry approximation. The solution i.e. primitive variables such as pressure, velocity components, temperature and turbulence quantities were passed from the first computational domain and specified as a supersonic boundary condition for the second simulation. (iii) The third domain comprised of the exit diffuser and the region in the vicinity of the facility (primary included to get the correct shock structure at the exit of the facility and entrainment characteristics). The first set of simulations comprising the engine, test cell and first stage ejectors was carried out both as a turbulent real gas calculation as well as a turbulent perfect gas calculation. A comparison for the two cases (Real Turbulent and Perfect gas turbulent) of the Ma Number distribution and temperature distributions are shown in Figures 1 and 2 respectively. The Mach Number distribution shows small yet distinct differences between the two cases such as locations of shocks/shock reflections and a slightly different impingement point on the wall of the diffuser from the expansion at the exit of the nozzle. Similarly the temperature distribution indicates different flow recirculation patterns in the test cell. Both cases capture all the essential flow phenomena such as the shock-boundary layer interaction, plume expansion, expansion of the first stage ejectors, mixing between the engine plume and the first stage ejector flow and pressurization due to the first stage ejectors. The final paper will discuss thermal loads on the walls of the diffuser and cooling mechanisms investigated.
The effect of state medicaid case-mix payment on nursing home resident acuity.
Feng, Zhanlian; Grabowski, David C; Intrator, Orna; Mor, Vincent
2006-08-01
To examine the relationship between Medicaid case-mix payment and nursing home resident acuity. Longitudinal Minimum Data Set (MDS) resident assessments from 1999 to 2002 and Online Survey Certification and Reporting (OSCAR) data from 1996 to 2002, for all freestanding nursing homes in the 48 contiguous U.S. states. We used a facility fixed-effects model to examine the effect of introducing state case-mix payment on changes in nursing home case-mix acuity. Facility acuity was measured by aggregating the nursing case-mix index (NCMI) from the MDS using the Resource Utilization Group (Version III) resident classification system, separately for new admits and long-stay residents, and by an OSCAR-derived index combining a range of activity of daily living dependencies and special treatment measures. We followed facilities over the study period to create a longitudinal data file based on the MDS and OSCAR, respectively, and linked facilities with longitudinal data on state case-mix payment policies for the same period. Across three acuity measures and two data sources, we found that states shifting to case-mix payment increased nursing home acuity levels over the study period. Specifically, we observed a 2.5 percent increase in the average acuity of new admits and a 1.3 to 1.4 percent increase in the acuity of long-stay residents, following the introduction of case-mix payment. The adoption of case-mix payment increased access to care for higher acuity Medicaid residents.
Internal Mixing Studied for GE/ARL Ejector Nozzle
NASA Technical Reports Server (NTRS)
Zaman, Khairul
2005-01-01
To achieve jet noise reduction goals for the High Speed Civil Transport aircraft, researchers have been investigating the mixer-ejector nozzle concept. For this concept, a primary nozzle with multiple chutes is surrounded by an ejector. The ejector mixes low-momentum ambient air with the hot engine exhaust to reduce the jet velocity and, hence, the jet noise. It is desirable to mix the two streams as fast as possible in order to minimize the length and weight of the ejector. An earlier model of the mixer-ejector nozzle was tested extensively in the Aerodynamic Research Laboratory (ARL) of GE Aircraft Engines at Cincinnati, Ohio. While testing was continuing with later generations of the nozzle, the earlier model was brought to the NASA Lewis Research Center for relatively fundamental measurements. Goals of the Lewis study were to obtain details of the flow field to aid computational fluid dynamics (CFD) efforts and obtain a better understanding of the flow mechanisms, as well as to experiment with mixing enhancement devices, such as tabs. The measurements were made in an open jet facility for cold (unheated) flow without a surrounding coflowing stream.
Methods for Scaling Icing Test Conditions
NASA Technical Reports Server (NTRS)
Anderson, David N.
1995-01-01
This report presents the results of tests at NASA Lewis to evaluate several methods to establish suitable alternative test conditions when the test facility limits the model size or operating conditions. The first method was proposed by Olsen. It can be applied when full-size models are tested and all the desired test conditions except liquid-water content can be obtained in the facility. The other two methods discussed are: a modification of the French scaling law and the AEDC scaling method. Icing tests were made with cylinders at both reference and scaled conditions representing mixed and glaze ice in the NASA Lewis Icing Research Tunnel. Reference and scale ice shapes were compared to evaluate each method. The Olsen method was tested with liquid-water content varying from 1.3 to .8 g/m(exp3). Over this range, ice shapes produced using the Olsen method were unchanged. The modified French and AEDC methods produced scaled ice shapes which approximated the reference shapes when model size was reduced to half the reference size for the glaze-ice cases tested.
None
2017-12-09
In 1999, the National Nuclear Security Administration (NNSA) signed a contract with a consortium, now called Shaw AREVA MOX Services, LLC to design, build, and operate a Mixed Oxide (MOX) Fuel Fabrication Facility. This facility will be a major component in the United States program to dispose of surplus weapon-grade plutonium. The facility will take surplus weapon-grade plutonium, remove impurities, and mix it with uranium oxide to form MOX fuel pellets for reactor fuel assemblies. These assemblies will be irradiated in commercial nuclear power reactors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2010-05-21
In 1999, the National Nuclear Security Administration (NNSA) signed a contract with a consortium, now called Shaw AREVA MOX Services, LLC to design, build, and operate a Mixed Oxide (MOX) Fuel Fabrication Facility. This facility will be a major component in the United States program to dispose of surplus weapon-grade plutonium. The facility will take surplus weapon-grade plutonium, remove impurities, and mix it with uranium oxide to form MOX fuel pellets for reactor fuel assemblies. These assemblies will be irradiated in commercial nuclear power reactors.
CONCEPTUAL DESIGN ASSESSMENT FOR THE CO-FIRING OF BIO-REFINERY SUPPLIED LIGNIN PROJECT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ted Berglund; Jeffrey T. Ranney; Carol L. Babb
2001-10-01
The major aspects of this project are proceeding toward completion. Prior to this quarter, design criteria, tentative site selection, facility layout, and preliminary facility cost estimates were completed and issued. Processing of bio-solids was completed, providing material for the pilot operations. Pilot facility design, equipment selection, and modification were completed during the fourth quarter of 2000. Initial pilot facility shakedown was completed. After some unavoidable delays, a suitable representative supply of MSW feed material was procured. During this first quarter of 2001, shredding of the feed material and final feed conditioning were completed. Pilot facility hydrolysis production was completed tomore » produce lignin for co-fire testing and the lignin fuel was washed and dewatered. Both the lignin and bio-solids fuel materials for co-fire testing were sent to the co-fire facility (EERC) for evaluation and co-firing. EERC has received coal typical of the fuel to the TVA-Colbert boilers. This material will be used at EERC as baseline material and for mixing with the bio-fuel for combustion testing. EERC combustion testing of the bio-based fuels is scheduled to begin in October of 2001. The TVA-Colbert facility has neared completion of the task to evaluate co-location of the Masada facility on the operation of the power generation facility. The TVA-Colbert fossil plant is fully capable of providing a reliable steam supply. The preferred steam supply connection points and steam pipeline routing have been identified. The environmental review of the pipeline routing has been completed and no major impacts have been identified. Detailed assessment of steam export impacts on the Colbert boiler system have been completed and a cost estimate for steam supply system was completed. The cost estimate and the output and heat rate impacts will be used to determine a preliminary price for the exported steam.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Black, S.C.; Townsend, Y.E.
1997-02-01
The Nevada Test Site (NTS), located in southern Nevada, has been the primary location for testing of nuclear explosives in the continental US. Testing began in 1951 and continued until the moratorium in 1992. Waste storage and disposal facilities for defense radioactive and mixed waste are located in Areas 3 and 5. At the Area 5 Radioactive Waste Management Site (RWMS-5), low-level wastes (LLW) from US Department of Energy (DOE) affiliated onsite and offsite generators are disposed of using standard shallow land disposal techniques. Transuranic wastes are retrievably stored at the RWMS-5 in containers on a surface pad, pending shipmentmore » to the Waste Isolation Pilot Plant facility in New Mexico. Nonradioactive hazardous wastes are accumulated at a special site before shipment to a licensed offsite disposal facility. Non-standard packages of LLW are buried in subsidence craters in the Area 3 RWMS. This report describes these activities on and around the NTS and includes a listing of the results obtained from environmental surveillance activities during the second calendar quarter of 1996.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-15
..., refinery fuel gas is generated by the facility's processes and collected into two fuel gas mix drums, designated 41V-33 and 45V-39. The gases are then distributed from these mix drums to combustion units at the facility, such as boilers and heaters. FHR Pine Bend operates H 2 S CEMs on the mix drums to satisfy the...
The effects of ownership and ownership change on nursing home industry costs.
Holmes, J S
1996-08-01
This study examines the effects of ownership type and ownership change on nursing home cost structures, differentiating patient care costs from plant costs. Administrative data from the Michigan Department of Social Services, Medical Services Administration (Medicaid), and the Michigan Department of Public Health are used. Cost data are based on audited cost reports for 393 nursing care facilities in Michigan in 1989. Other facility characteristics are based on data from the 1989 annual licensing and certification survey conducted by the Michigan Department of Public Health. A series of ordinary least squares regressions is estimated, in which the dependent variable is either per diem patient costs or per diem plant costs. Ownership types are defined as chain, proprietary non-chain, freestanding non-profit, government-owned, and hospital-based facilities. Pooled estimation techniques, as well as separate regressions by ownership type, are presented to test for interaction effects. Key variables include whether a facility changed ownership in the preceding five years and whether chain facilities are in-state- or out-of-state-owned, in addition to size, payer mix, and case mix. Behavioral differences among nursing home ownership types in respect to patient care costs tended to distinguish government-owned and hospital-based facilities from the freestanding homes rather than the usual distinction between for-profit and not-for-profit classes. Variables traditionally included in nursing home cost studies, such as size, occupancy, payer mix and case mix, were found to have similar effects on per diem patient care costs for freestanding non-profit homes as well as for chain proprietary facilities. With regard to the effects of ownership change on per diem plant and per diem patient costs, however, there are few differences among ownership types. Chain and non-chain for-profit facilities, non-profit homes, and hospital long-term care units that had changed ownership reported significantly higher per diem plant costs than facilities without a change of ownership, but did not spend more on patient-related costs. Michigan Medicaid plant reimbursement system policy changes instituted in 1985 to promote continued ownership of facilities were not entirely successful. Non-profit homes look increasingly like their for-profit counterparts with respect to spending on patient care costs. Increased competition for the more lucrative private-pay patients, coupled with declining state Medicaid reimbursement to nursing homes, may have blurred the historical distinctions between the non-profit and for-profit sectors in the nursing home industry. An exception to increasing homogeneity within the nursing home industry is the tendency of proprietary homes to experience more frequent changes of ownership, which results in higher capital costs passed on to state Medicaid programs. Findings from this study indicate that while facility sales increase per diem plant costs, they do not result in increased spending for direct patient care, suggesting that state Medicaid programs may be indirectly subsidizing facility sales with no accompanying increase in expenditures for patient care. To discourage frequent facility sales, state Medicaid programs may need to consider alternative methods of reimbursing nursing home owners for capital costs.
Brenner, Stephan; Muula, Adamson S; Robyn, Paul Jacob; Bärnighausen, Till; Sarker, Malabika; Mathanga, Don P; Bossert, Thomas; De Allegri, Manuela
2014-04-22
In this article we present a study design to evaluate the causal impact of providing supply-side performance-based financing incentives in combination with a demand-side cash transfer component on equitable access to and quality of maternal and neonatal healthcare services. This intervention is introduced to selected emergency obstetric care facilities and catchment area populations in four districts in Malawi. We here describe and discuss our study protocol with regard to the research aims, the local implementation context, and our rationale for selecting a mixed methods explanatory design with a quasi-experimental quantitative component. The quantitative research component consists of a controlled pre- and post-test design with multiple post-test measurements. This allows us to quantitatively measure 'equitable access to healthcare services' at the community level and 'healthcare quality' at the health facility level. Guided by a theoretical framework of causal relationships, we determined a number of input, process, and output indicators to evaluate both intended and unintended effects of the intervention. Overall causal impact estimates will result from a difference-in-difference analysis comparing selected indicators across intervention and control facilities/catchment populations over time.To further explain heterogeneity of quantitatively observed effects and to understand the experiential dimensions of financial incentives on clients and providers, we designed a qualitative component in line with the overall explanatory mixed methods approach. This component consists of in-depth interviews and focus group discussions with providers, service user, non-users, and policy stakeholders. In this explanatory design comprehensive understanding of expected and unexpected effects of the intervention on both access and quality will emerge through careful triangulation at two levels: across multiple quantitative elements and across quantitative and qualitative elements. Combining a traditional quasi-experimental controlled pre- and post-test design with an explanatory mixed methods model permits an additional assessment of organizational and behavioral changes affecting complex processes. Through this impact evaluation approach, our design will not only create robust evidence measures for the outcome of interest, but also generate insights on how and why the investigated interventions produce certain intended and unintended effects and allows for a more in-depth evaluation approach.
Tighiouart, Hocine; Meyer, Klemens B.; Miskulin, Dana C.
2011-01-01
The Centers for Medicare and Medicaid Services (CMS) designated the achieved urea reduction ratio (URR) as a pay-for-performance measure, but to what extent this measure reflects patient characteristics and adherence instead of its intent to reflect facility performance is unknown. Here, we quantified the contributions of patient case-mix and adherence to the variability in achieving URR targets across dialysis facilities. We found that 92% of 10,069 hemodialysis patients treated at 173 facilities during the last quarter of 2004 achieved the target URR ≥65%. Mixed-effect models with random intercept for dialysis facility revealed a significant facility effect: 11.5% of the variation in achievement of target URR was attributable to the facility level. Adjusting for patient case-mix reduced the proportion of variation attributable to the facility level to 6.7%. Patient gender, body surface area, dialysis access, and adherence with treatment strongly associated with achievement of the URR target. We could not identify specific facility characteristics that explained the remaining variation between facilities. These data suggest that if adherence is not a modifiable patient characteristic, providers could be unfairly penalized for caring for these patients under current CMS policy. These penalties may have unintended consequences. PMID:22025629
Hot Corrosion Test Facility at the NASA Lewis Special Projects Laboratory
NASA Technical Reports Server (NTRS)
Robinson, Raymond C.; Cuy, Michael D.
1994-01-01
The Hot Corrosion Test Facility (HCTF) at the NASA Lewis Special Projects Laboratory (SPL) is a high-velocity, pressurized burner rig currently used to evaluate the environmental durability of advanced ceramic materials such as SiC and Si3N4. The HCTF uses laboratory service air which is preheated, mixed with jet fuel, and ignited to simulate the conditions of a gas turbine engine. Air, fuel, and water systems are computer-controlled to maintain test conditions which include maximum air flows of 250 kg/hr (550 lbm/hr), pressures of 100-600 kPa (1-6 atm), and gas temperatures exceeding 1500 C (2732 F). The HCTF provides a relatively inexpensive, yet sophisticated means for researchers to study the high-temperature oxidation of advanced materials, and the injection of a salt solution provides the added capability of conducting hot corrosion studies.
Case-Mix Adjustment of the Bereaved Family Survey.
Kutney-Lee, Ann; Carpenter, Joan; Smith, Dawn; Thorpe, Joshua; Tudose, Alina; Ersek, Mary
2018-01-01
Surveys of bereaved family members are increasingly being used to evaluate end-of-life (EOL) care and to measure organizational performance in EOL care quality. The Bereaved Family Survey (BFS) is used to monitor EOL care quality and benchmark performance in the Veterans Affairs (VA) health-care system. The objective of this study was to develop a case-mix adjustment model for the BFS and to examine changes in facility-level scores following adjustment, in order to provide fair comparisons across facilities. We conducted a cross-sectional secondary analysis of medical record and survey data from veterans and their family members across 146 VA medical centers. Following adjustment using model-based propensity weighting, the mean change in the BFS-Performance Measure score across facilities was -0.6 with a range of -2.6 to 0.6. Fifty-five (38%) facilities changed within ±0.5 percentage points of their unadjusted score. On average, facilities that benefited most from adjustment cared for patients with greater comorbidity burden and were located in urban areas in the Northwest and Midwestern regions of the country. Case-mix adjustment results in minor changes to facility-level BFS scores but allows for fairer comparisons of EOL care quality. Case-mix adjustment of the BFS positions this National Quality Forum-endorsed measure for use in public reporting and internal quality dashboards for VA leadership and may inform the development and refinement of case-mix adjustment models for other surveys of bereaved family members.
NASA Astrophysics Data System (ADS)
Lu, Guoping; Sonnenthal, Eric L.; Bodvarsson, Gudmundur S.
2008-12-01
The standard dual-component and two-member linear mixing model is often used to quantify water mixing of different sources. However, it is no longer applicable whenever actual mixture concentrations are not exactly known because of dilution. For example, low-water-content (low-porosity) rock samples are leached for pore-water chemical compositions, which therefore are diluted in the leachates. A multicomponent, two-member mixing model of dilution has been developed to quantify mixing of water sources and multiple chemical components experiencing dilution in leaching. This extended mixing model was used to quantify fracture-matrix interaction in construction-water migration tests along the Exploratory Studies Facility (ESF) tunnel at Yucca Mountain, Nevada, USA. The model effectively recovers the spatial distribution of water and chemical compositions released from the construction water, and provides invaluable data on the matrix fracture interaction. The methodology and formulations described here are applicable to many sorts of mixing-dilution problems, including dilution in petroleum reservoirs, hydrospheres, chemical constituents in rocks and minerals, monitoring of drilling fluids, and leaching, as well as to environmental science studies.
The Effect of State Medicaid Case-Mix Payment on Nursing Home Resident Acuity
Feng, Zhanlian; Grabowski, David C; Intrator, Orna; Mor, Vincent
2006-01-01
Objective To examine the relationship between Medicaid case-mix payment and nursing home resident acuity. Data Sources Longitudinal Minimum Data Set (MDS) resident assessments from 1999 to 2002 and Online Survey Certification and Reporting (OSCAR) data from 1996 to 2002, for all freestanding nursing homes in the 48 contiguous U.S. states. Study Design We used a facility fixed-effects model to examine the effect of introducing state case-mix payment on changes in nursing home case-mix acuity. Facility acuity was measured by aggregating the nursing case-mix index (NCMI) from the MDS using the Resource Utilization Group (Version III) resident classification system, separately for new admits and long-stay residents, and by an OSCAR-derived index combining a range of activity of daily living dependencies and special treatment measures. Data Collection/Extraction Methods We followed facilities over the study period to create a longitudinal data file based on the MDS and OSCAR, respectively, and linked facilities with longitudinal data on state case-mix payment policies for the same period. Principal Findings Across three acuity measures and two data sources, we found that states shifting to case-mix payment increased nursing home acuity levels over the study period. Specifically, we observed a 2.5 percent increase in the average acuity of new admits and a 1.3 to 1.4 percent increase in the acuity of long-stay residents, following the introduction of case-mix payment. Conclusions The adoption of case-mix payment increased access to care for higher acuity Medicaid residents. PMID:16899009
NASA Technical Reports Server (NTRS)
Harrington, Douglas (Technical Monitor); Schweiger, P.; Stern, A.; Gamble, E.; Barber, T.; Chiappetta, L.; LaBarre, R.; Salikuddin, M.; Shin, H.; Majjigi, R.
2005-01-01
Hot flow aero-acoustic tests were conducted with Pratt & Whitney's High-Speed Civil Transport (HSCT) Mixer-Ejector Exhaust Nozzles by General Electric Aircraft Engines (GEAE) in the GEAE Anechoic Freejet Noise Facility (Cell 41) located in Evendale, Ohio. The tests evaluated the impact of various geometric and design parameters on the noise generated by a two-dimensional (2-D) shrouded, 8-lobed, mixer-ejector exhaust nozzle. The shrouded mixer-ejector provides noise suppression by mixing relatively low energy ambient air with the hot, high-speed primary exhaust jet. Additional attenuation was obtained by lining the shroud internal walls with acoustic panels, which absorb acoustic energy generated during the mixing process. Two mixer designs were investigated, the high mixing "vortical" and aligned flow "axial", along with variations in the shroud internal mixing area ratios and shroud length. The shrouds were tested as hardwall or lined with acoustic panels packed with a bulk absorber. A total of 21 model configurations at 1:11.47 scale were tested. The models were tested over a range of primary nozzle pressure ratios and primary exhaust temperatures representative of typical HSCT aero thermodynamic cycles. Static as well as flight simulated data were acquired during testing. A round convergent unshrouded nozzle was tested to provide an acoustic baseline for comparison to the test configurations. Comparisons were made to previous test results obtained with this hardware at NASA Glenn's 9- by 15-foot low-speed wind tunnel (LSWT). Laser velocimetry was used to investigate external as well as ejector internal velocity profiles for comparison to computational predictions. Ejector interior wall static pressure data were also obtained. A significant reduction in exhaust system noise was demonstrated with the 2-D shrouded nozzle designs.
National profile on commercially generated low-level radioactive mixed waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klein, J.A.; Mrochek, J.E.; Jolley, R.L.
1992-12-01
This report details the findings and conclusions drawn from a survey undertaken as part of a joint US Nuclear Regulatory Commission and US Environmental Protection Agency-sponsored project entitled ``National Profile on Commercially Generated Low-Level Radioactive Mixed Waste.`` The overall objective of the work was to compile a national profile on the volumes, characteristics, and treatability of commercially generated low-level mixed waste for 1990 by five major facility categories-academic, industrial, medical, and NRC-/Agreement State-licensed goverment facilities and nuclear utilities. Included in this report are descriptions of the methodology used to collect and collate the data, the procedures used to estimate themore » mixed waste generation rate for commercial facilities in the United States in 1990, and the identification of available treatment technologies to meet applicable EPA treatment standards (40 CFR Part 268) and, if possible, to render the hazardous component of specific mixed waste streams nonhazardous. The report also contains information on existing and potential commercial waste treatment facilities that may provide treatment for specific waste streams identified in the national survey. The report does not include any aspect of the Department of Energy`s (DOES) management of mixed waste and generally does not address wastes from remedial action activities.« less
Cohen, J W; Dubay, L C
1990-01-01
In this study we analyze the effects of ownership and Medicaid cost containment initiatives on nursing home costs, payer mix, case mix, and staffing, using 1981 Medicare cost reports and Medicare/Medicaid Automated Certification files. As Medicaid cost containment incentives become stronger, nursing homes respond by decreasing case mix and commensurately decreasing staffing. When these incentives are especially strong, staffing is reduced beyond the apparently appropriate level, given the case mix. In addition, while chain facilities have lower costs than other types of facilities, these lower costs do not appear to come from either increased cream-skimming or reduced staffing levels.
2009-08-11
This final rule updates the payment rates used under the prospective payment system (PPS) for skilled nursing facilities (SNFs), for fiscal year (FY) 2010. In addition, it recalibrates the case-mix indexes so that they more accurately reflect parity in expenditures related to the implementation of case-mix refinements in January 2006. It also discusses the results of our ongoing analysis of nursing home staff time measurement data collected in the Staff Time and Resource Intensity Verification project, as well as a new Resource Utilization Groups, version 4 case-mix classification model for FY 2011 that will use the updated Minimum Data Set 3.0 resident assessment for case-mix classification. In addition, this final rule discusses the public comments that we have received on these and other issues, including a possible requirement for the quarterly reporting of nursing home staffing data, as well as on applying the quality monitoring mechanism in place for all other SNF PPS facilities to rural swing-bed hospitals. Finally, this final rule revises the regulations to incorporate certain technical corrections.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cozzi, A.; Crawford, C.; Fox, K.
More than 56 million gallons of radioactive and hazardous waste are stored in 177 underground storage tanks at the U.S. Department of Energy’s (DOE’s) Hanford Site in Washington State. The HLW will be vitrified in the HLW facility for ultimate disposal at an offsite federal repository. A portion (~35%) of the LAW will be vitrified in the LAW vitrification facility for disposal onsite at the Integrated Disposal Facility (IDF). The pretreatment and HLW vitrification facilities will have the capacity to treat and immobilize all of the wastes destined for those facilities. However, a second facility will be needed for themore » expected volume of LAW requiring immobilization. Cast Stone, a cementitious waste form, is being considered to provide the required additional LAW immobilization capacity. The Cast Stone waste form must be acceptable for disposal in the IDF. The Cast Stone waste form and immobilization process must be tested to demonstrate that the final Cast Stone waste form can comply with the waste acceptance criteria for the disposal facility and that the immobilization processes can be controlled to consistently provide an acceptable waste form product. A testing program was developed in fiscal year (FY) 2012 describing in detail the work needed to develop and qualify Cast Stone as a waste form for the solidification of Hanford LAW. A statistically designed test matrix was used to evaluate the effects of key parameters on the properties of the Cast Stone as it is initially prepared and after curing. For the processing properties, the water-to-dry-blend mix ratio was the most significant parameter in affecting the range of values observed for each property. The single shell tank (SST) Blend simulant also showed differences in measured properties compared to the other three simulants tested. A review of the testing matrix and results indicated that an additional set of tests would be beneficial to improve the understanding of the impacts noted in the Screening Matrix tests. A set of Cast Stone formulations were devised to augment the original screening test matrix and focus on the range of the test conditions. Fly ash and blast furnace slag were limited to either northwest or southeast and the salt solutions were narrowed to the Average and the SST Blend at the 7.8M Na concentration. To fill in the matrix, a mix ratio of 0.5 was added. In addition, two admixtures, Xypex Admix C-500 and Rheomac SF100 (silica fume), were added as an additional dry material binder in select compositions. As in the Screening Matrix, both fresh and cured properties were evaluated for the formulations. In this study, properties that were influenced by the W/DM ratio in the Screening Matrix; flow diameter, plastic viscosity, density, and compressive strength, showed consistent behavior with respect to W/DM. The leach index for highly soluble components, sodium and nitrate, were not influenced by changes in formulation or the admixtures. The leach index for both iodine and Tc-99 show an influence from the addition of the admixture, Xypex Admix C-500. Additional testing should be performed to further evaluate the influence of Xypex Admix C-500 on the leach index over a range of admixture concentrations, Cast Stone formulations, and curing and storage conditions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sasser, K.
1994-06-01
In FY 1993, the Los Alamos National Laboratory Waste Management Group [CST-7 (formerly EM-7)] requested the Probabilistic Risk and Hazards Analysis Group [TSA-11 (formerly N-6)] to conduct a study of the hazards associated with several CST-7 facilities. Among these facilities are the Hazardous Waste Treatment Facility (HWTF), the HWTF Drum Storage Building (DSB), and the Mixed Waste Receiving and Storage Facility (MWRSF), which are proposed for construction beginning in 1996. These facilities are needed to upgrade the Laboratory`s storage capability for hazardous and mixed wastes and to provide treatment capabilities for wastes in cases where offsite treatment is not availablemore » or desirable. These facilities will assist Los Alamos in complying with federal and state requlations.« less
Quality choice in Medicaid markets. The case of nursing homes.
McKay, N L
1989-01-01
This article examines whether private patients, who typically pay a price higher than the Medicaid reimbursement rate, receive the same or higher quality services than Medicaid patients in the same health care facility. Because the mix of patients will affect the firm's cost only when Medicaid and private patients receive different levels of quality, the cost function can be used to test for the presence of quality differences. Estimates of a cost function for Texas nursing home in 1983 indicate that the mix of patients does not affect the firm's cost. Thus, private and Medicaid patients in the same nursing home receive the same level of quality.
Use of Ground Penetrating Radar at the FAA's National Airport Pavement Test Facility
NASA Astrophysics Data System (ADS)
Injun, Song
2015-04-01
The Federal Aviation Administration (FAA) in the United States has used a ground-coupled Ground Penetrating Radar (GPR) at the National Airport Pavement Test Facility (NAPTF) since 2005. One of the primary objectives of the testing at the facility is to provide full-scale pavement response and failure information for use in airplane landing gear design and configuration studies. During the traffic testing at the facility, a GSSI GPR system was used to develop new procedures for monitoring Hot Mix Asphalt (HMA) pavement density changes that is directly related to pavement failure. After reviewing current setups for data acquisition software and procedures for identifying different pavement layers, dielectric constant and pavement thickness were selected as dominant parameters controlling HMA properties provided by GPR. A new methodology showing HMA density changes in terms of dielectric constant variations, called dielectric sweep test, was developed and applied in full-scale pavement test. The dielectric constant changes were successfully monitored with increasing airplane traffic numbers. The changes were compared to pavement performance data (permanent deformation). The measured dielectric constants based on the known HMA thicknesses were also compared with computed dielectric constants using an equation from ASTM D4748-98 Standard Test Method for Determining the Thickness of Bound Pavement Layers Using Short-Pulse Radar. Six inches diameter cylindrical cores were taken after construction and traffic testing for the HMA layer bulk specific gravity. The measured bulk specific gravity was also compared to monitor HMA density changes caused by aircraft traffic conditions. Additionally this presentation will review the applications of the FAA's ground-coupled GPR on embedded rebar identification in concrete pavement, sewer pipes in soil, and gage identifications in 3D plots.
BLENDING ANALYSIS FOR RADIOACTIVE SALT WASTE PROCESSING FACILITY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, S.
2012-05-10
Savannah River National Laboratory (SRNL) evaluated methods to mix and blend the contents of the blend tanks to ensure the contents are properly blended before they are transferred from the blend tank such as Tank 21 and Tank 24 to the Salt Waste Processing Facility (SWPF) feed tank. The tank contents consist of three forms: dissolved salt solution, other waste salt solutions, and sludge containing settled solids. This paper focuses on developing the computational model and estimating the operation time of submersible slurry pump when the tank contents are adequately blended prior to their transfer to the SWPF facility. Amore » three-dimensional computational fluid dynamics approach was taken by using the full scale configuration of SRS Type-IV tank, Tank 21H. Major solid obstructions such as the tank wall boundary, the transfer pump column, and three slurry pump housings including one active and two inactive pumps were included in the mixing performance model. Basic flow pattern results predicted by the computational model were benchmarked against the SRNL test results and literature data. Tank 21 is a waste tank that is used to prepare batches of salt feed for SWPF. The salt feed must be a homogeneous solution satisfying the acceptance criterion of the solids entrainment during transfer operation. The work scope described here consists of two modeling areas. They are the steady state flow pattern calculations before the addition of acid solution for tank blending operation and the transient mixing analysis during miscible liquid blending operation. The transient blending calculations were performed by using the 95% homogeneity criterion for the entire liquid domain of the tank. The initial conditions for the entire modeling domain were based on the steady-state flow pattern results with zero second phase concentration. The performance model was also benchmarked against the SRNL test results and literature data.« less
Contractor Logistics Support in the U.S. Air Force
2009-01-01
limits), or it can engage in a mix of the two approaches.2 This monograph addresses CLS, which is defined as contractor sustainment of a weapon system...organic facilities; it can pay contractors to do the work (subject to some congressional limits); or it can apply a mix of the two approaches.2 Organic...levels are largely stable and represent a mix of services, including contractor operated facilities and instal- Figure 3.1 Air Force CSS for Weapon
Liu, Chuan-Fen; Sales, Anne E; Sharp, Nancy D; Fishman, Paul; Sloan, Kevin L; Todd-Stenberg, Jeff; Nichol, W Paul; Rosen, Amy K; Loveland, Susan
2003-01-01
Objective To compare the rankings for health care utilization performance measures at the facility level in a Veterans Health Administration (VHA) health care delivery network using pharmacy- and diagnosis-based case-mix adjustment measures. Data Sources/Study Setting The study included veterans who used inpatient or outpatient services in Veterans Integrated Service Network (VISN) 20 during fiscal year 1998 (October 1997 to September 1998; N=126,076). Utilization and pharmacy data were extracted from VHA national databases and the VISN 20 data warehouse. Study Design We estimated concurrent regression models using pharmacy or diagnosis information in the base year (FY1998) to predict health service utilization in the same year. Utilization measures included bed days of care for inpatient care and provider visits for outpatient care. Principal Findings Rankings of predicted utilization measures across facilities vary by case-mix adjustment measure. There is greater consistency within the diagnosis-based models than between the diagnosis- and pharmacy-based models. The eight facilities were ranked differently by the diagnosis- and pharmacy-based models. Conclusions Choice of case-mix adjustment measure affects rankings of facilities on performance measures, raising concerns about the validity of profiling practices. Differences in rankings may reflect differences in comparability of data capture across facilities between pharmacy and diagnosis data sources, and unstable estimates due to small numbers of patients in a facility. PMID:14596393
Lagrada, Leizel P; Uehara, Naruo; Kawahara, Kazuo
2008-12-01
STUDY BACKGROUND AND OBJECTIVES: The Philippines is one of the 22 countries with high TB burden. DOTS was adopted not only by purely public providers (PP) but also by public-private mix (PPM) facilities. This study aims to identify the patient and facility factors that promote completion of TB treatment in DOTS facilities in an urban setting. The study also explores the difference between the PP and PPM DOTS facilities in terms of case management and treatment outcomes. [Methods] A case control study was done by interviewing 394 patients sampled from TB cohort report between 2003 and 2005 of 14 DOTS facilities in Metro Manila. Statistical analyses used include chi-square test and logistic regression analysis. Being female and aged 30-44 (OR = 7.04; 95% CI 1.12-44.35), unemployed (OR = 2.73; 95% CI 1.18-6.33), being above per capita poverty threshold (OR = 2.03; 95% CI 1.03-3.99), having experienced at least one of the signs and symptoms of TB (OR = 4.64; 95% CI 1.29-16.67), taking the medication at health facility (OR = 3.87; 95% CI 1.48-10.16) and patient's understanding of DOT (OR = 2.67; 95% CI 1.37-5.23) predict TB treatment completion. Public-private mix type of DOTS facility was also significantly associated with completing treatment (chi 2 (1) = 54.76, p = 0.000). Patient factors like middle-aged female compared to female aged more than 60, being above per capita poverty threshold, unemployment and having experienced at least one signs and symptoms of TB and facility factors like providing treatment at the facility and explaining the DOT to patient increase the likelihood of completing treatment. Thus, encouraging patients to take their medication at the facility and helping the patients understand the importance of DOT can increase TB treatment completion. The seemingly better DOTS implementation and treatment outcomes by the PPM must be evaluated further through cost effectiveness and efficiency studies.
Ignition and Performance Tests of Rocket-Based Combined Cycle Propulsion System
NASA Technical Reports Server (NTRS)
Anderson, William E.
2005-01-01
The ground testing of a Rocket Based Combined Cycle engine implementing the Simultaneous Mixing and Combustion scheme was performed at the direct-connect facility of Purdue University's High Pressure Laboratory. The fuel-rich exhaust of a JP-8/H2O2 thruster was mixed with compressed, metered air in a constant area, axisymmetric duct. The thruster was similar in design and function to that which will be used in the flight test series of Dryden's Ducted-Rocket Experiment. The determination of duct ignition limits was made based on the variation of secondary air flow rates and primary thruster equivalence ratios. Thrust augmentation and improvements in specific impulse were studied along with the pressure and temperature profiles of the duct to study mixing lengths and thermal choking. The occurrence of ignition was favored by lower rocket equivalence ratios. However, among ignition cases, better thrust and specific impulse performance were seen with higher equivalence ratios owing to the increased fuel available for combustion. Thrust and specific impulse improvements by factors of 1.2 to 1.7 were seen. The static pressure and temperature profiles allowed regions of mixing and heat addition to be identified. The mixing lengths were found to be shorter at lower rocket equivalence ratios. Total pressure measurements allowed plume-based calculation of thrust, which agreed with load-cell measured values to within 6.5-8.0%. The corresponding Mach Number profile indicated the flow was not thermally choked for the highest duct static pressure case.
NASA Technical Reports Server (NTRS)
Harrington, Douglas E.
1998-01-01
The aerospace industry is currently investigating the effect of installing mixer/ejector nozzles on the core flow exhaust of high-bypass-ratio turbofan engines. This effort includes both full-scale engine tests at sea level conditions and subscale tests in static test facilities. Subscale model tests are to be conducted prior to full-scale testing. With this approach, model results can be analyzed and compared with analytical predications. Problem areas can then be identified and design changes made and verified in subscale prior to committing to any final design configurations for engine ground tests. One of the subscale model test programs for the integrated mixer/ejector development was a joint test conducted by the NASA Lewis Research Center and Pratt & Whitney Aircraft. This test was conducted to study various mixer/ejector nozzle configurations installed on the core flow exhaust of advanced, high-bypass-ratio turbofan engines for subsonic, commercial applications. The mixer/ejector concept involves the introduction of largescale, low-loss, streamwise vortices that entrain large amounts of secondary air and rapidly mix it with the primary stream. This results in increased ejector pumping relative to conventional ejectors and in more complete mixing within the ejector shroud. The latter improves thrust performance through the efficient energy exchange between the primary and secondary streams. This experimental program was completed in April 1997 in Lewis' CE-22 static test facility. Variables tested included the nozzle area ratio (A9/A8), which ranged from 1.6 to 3.0. This ratio was varied by increasing or decreasing the nozzle throat area, A8. Primary nozzles tested included both lobed mixers and conical primaries. These configurations were tested with and without an outer shroud, and the shroud position was varied by inserting spacers in it. In addition, data were acquired with and without secondary flow.
Neutron measurements from beam-target reactions at the ELISE neutral beam test facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xufei, X., E-mail: xiexufei@pku.edu.cn; Fan, T.; Nocente, M.
2014-11-15
Measurements of 2.5 MeV neutron emission from beam-target reactions performed at the ELISE neutral beam test facility are presented in this paper. The measurements are used to study the penetration of a deuterium beam in a copper dump, based on the observation of the time evolution of the neutron counting rate from beam-target reactions with a liquid scintillation detector. A calculation based on a local mixing model of deuterium deposition in the target up to a concentration of 20% at saturation is used to evaluate the expected neutron yield for comparison with data. The results are of relevance to understandmore » neutron emission associated to beam penetration in a solid target, with applications to diagnostic systems for the SPIDER and MITICA Neutral Beam Injection prototypes.« less
Diffusion Limited Supercritical Water Oxidation (SCWO) in Microgravity Environments
NASA Technical Reports Server (NTRS)
Hicks, M. C.; Lauver, R. W.; Hegde, U. G.; Sikora, T. J.
2006-01-01
Tests designed to quantify the gravitational effects on thermal mixing and reactant injection in a Supercritical Water Oxidation (SCWO) reactor have recently been performed in the Zero Gravity Facility (ZGF) at NASA s Glenn Research Center. An artificial waste stream, comprising aqueous mixtures of methanol, was pressurized to approximately 250 atm and then heated to 450 C. After uniform temperatures in the reactor were verified, a controlled injection of air was initiated through a specially designed injector to simulate diffusion limited reactions typical in most continuous flow reactors. Results from a thermal mapping of the reaction zone in both 1-g and 0-g environments are compared. Additionally, results of a numerical model of the test configuration are presented to illustrate first order effects on reactant mixing and thermal transport in the absence of gravity.
Zhao, XiangLong; Chen, WeiJia; Liu, ZhengHua; Guo, JiaLiang; Zhou, ZhengYin; Crommen, Jacques; Moaddel, Ruin; Jiang, ZhengJin
2014-11-07
Drug-induced phospholipidosis (PLD) is characterized by the excessive accumulation of phospholipids, resulting in multilamellar vesicle structure within lysosomes. In the present study, a novel mixed phospholipid functionalized monolithic column was developed for the first time through a facile one-step co-polymerization approach. The phospholipid composition of the monolith can be adjusted quantitatively and accurately to mimic the mixed phospholipid environment of different biomembranes on a solid matrix. The mixed phospholipid functionalized monolith as a promising immobilized artificial membrane technique was used to study drug-phospholipid interaction. Scanning electron microscopy, elemental analysis, FT-IR spectra, ζ-potential analysis and micro-HPLC were carried out to characterize the physicochemical properties and separation performance of the monolith. Mechanism studies revealed that both hydrophobic and electrostatic interactions play an important role in the retention of analytes. The ratio of their contributions to retention can be easily manipulated by adjusting the composition of the mixed phospholipids, in order to better mimic the interaction between drugs and cell membrane. The obtained mixed phospholipid functionalized monolithic columns were applied to the screening of drug-induced PLD potency. Data from 79 drugs on the market demonstrated that the chromatographic hydrophobicity index referring to the mixed phospholipid functionalized monolith at pH 7.4 (CHI IAM7.4) for the selected drugs were highly correlated with the drug-induced PLD potency data obtained from other in vivo or in vitro assays. Moreover, the effect of the acidic phospholipid phosphatidylserine proportion on prediction accuracy was also investigated. The monolith containing 20% phosphatidylserine and 80% phosphatidylcholine exhibited the best prediction ability for the drug-induced PLD potency of the tested compounds. This research has led to the successful development of a novel and facile approach to prepare a mixed phospholipids functionalized monolith, which offers a reliable, cost-effective and high-throughput screening tool for early prediction of the PLD potency of drug candidates. Copyright © 2014 Elsevier B.V. All rights reserved.
Nursing home costs, Medicaid rates, and profits under alternative Medicaid payment systems.
Schlenker, R E
1991-01-01
This analysis compares nursing home costs, Medicaid payment rates, and profits under three Medicaid nursing home payment systems: case-mix, facility-specific, and class-rate systems. Data used were collected from 135 nursing homes in seven states. The association of case mix with costs, rates, and profits under the three payment systems was of particular interest. Case mix was more strongly associated (positively) with patient care cost and the Medicaid rate for the case-mix systems than for the other systems, particularly the class-rate systems. In contrast, case mix and profits were not associated in the case-mix or facility-specific systems, but were negatively associated in the class rate systems. Overall, the results suggest that case-mix systems have some important advantages over other payment systems, but further research is needed on larger samples and involving the newer case-mix systems. PMID:1743972
Case mix, quality, and cost relationships in Colorado nursing homes.
Schlenker, R E; Shaughessy, P W
1984-01-01
The analyses reported in this article assessed the cost, case mix, and quality interrelationships among Colorado nursing homes. A unique set of patient-level data was collected specifically to measure case mix and quality. Case mix was found to be strongly associated with cost, accounting for up to 45 percent of the variation in cost per patient day. The relationship between quality and cost was weaker; quality variables accounted for only about 10 percent of the cost per day variation. Case mix was also associated with several facility characteristics found to be significant in other cost studies, suggesting that such facility characteristics serve as partial proxy measures for case mix. The cost-case mix relationships appear to be strong enough to justify incorporating case mix directly in nursing home reimbursement systems. In contrast, the weaker cost-quality association implies that it may not (yet) be appropriate to incorporate quality directly in reimbursement.
Rantz, Marilyn J.; Nahm, Helen E.; Zwygart-Stauffacher, Mary; Hicks, Lanis; Mehr, David; Flesner, Marcia; Petroski, Gregory F.; Madsen, Richard W.; Scott-Cawiezell, Jill
2012-01-01
Purpose A comprehensive multilevel intervention was tested to build organizational capacity to create and sustain improvement in quality of care and subsequently improve resident outcomes in nursing homes in need of improvement. Intervention facilities (n=29) received a two-year multilevel intervention with monthly on-site consultation from expert nurses with graduate education in gerontological nursing. Attention control facilities (n=29) that also needed to improve resident outcomes received monthly information about aging and physical assessment of elders. Design and Methods Randomized clinical trial of nursing homes in need of improving resident outcomes of bladder and bowel incontinence, weight loss, pressure ulcers, and decline in activities of daily living (ADL). It was hypothesized that following the intervention, experimental facilities would have better resident outcomes, higher quality of care, higher staff retention, more organizational attributes of improved working conditions than control facilities, similar staffing and staff mix, and lower total and direct care costs. Results The intervention did improve quality of care (p=0.02); there were improvements in pressure ulcers (p=0.05), weight loss (p=0.05). Staff retention, organizational working conditions, staffing, and staff mix and most costs were not affected by the intervention. Leadership turnover was surprisingly excessive in both intervention and control groups. Implications Some facilities that are in need of improving quality of care and resident outcomes are able to build the organizational capacity to improve while not increasing staffing or costs of care. Improvement requires continuous supportive consultation and leadership willing to involve staff and work together to build the systematic improvements in care delivery needed. PMID:21816681
NASA Johnson Space Center Usability Testing and Analysis facility (UTAF) Overview
NASA Technical Reports Server (NTRS)
Whitmore, Mihriban; Holden, Kritina L.
2005-01-01
The Usability Testing and Analysis Facility (UTAF) is part of the Space Human Factors Laboratory at the NASA Johnson Space Center in Houston, Texas. The facility performs research for NASA's HumanSystems Integration Program, under the HumanSystems Research and Technology Division. Specifically, the UTAF provides human factors support for space vehicles, including the International Space Station, the Space Shuttle, and the forthcoming Crew Exploration Vehicle. In addition, there are ongoing collaborative research efforts with external corporations and universities. The UTAF provides human factors analysis, evaluation, and usability testing of crew interfaces for space applications. This includes computer displays and controls, workstation systems, and work environments. The UTAF has a unique mix of capabilities, with a staff experienced in both cognitive human factors and ergonomics. The current areas of focus are: human factors applications in emergency medical care and informatics; control and display technologies for electronic procedures and instructions; voice recognition in noisy environments; crew restraint design for unique microgravity workstations; and refinement of human factors processes and requirements. This presentation will provide an overview of ongoing activities, and will address how the UTAF projects will evolve to meet new space initiatives.
1999 Report on Hanford Site land disposal restriction for mixed waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
BLACK, D.G.
This report was submitted to meet the requirements of Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) Milestone M-26-011. This milestone requires the preparation of an annual report that covers characterization, treatment, storage, minimization, and other aspects of managing land-disposal-restricted mixed waste at the Hanford Facility.
Letter Report: LAW Simulant Development for Cast Stone Screening Test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Russell, Renee L.; Westsik, Joseph H.; Swanberg, David J.
2013-03-27
More than 56 million gallons of radioactive and hazardous waste are stored in 177 underground storage tanks at the U.S. Department of Energy’s (DOE’s) Hanford Site in southeastern Washington State. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is being constructed to treat the wastes and immobilize them in a glass waste form. The WTP includes a pretreatment facility to separate the wastes into a small volume of high-level waste (HLW) containing most of the radioactivity and a larger volume of low-activity waste (LAW) containing most of the nonradioactive chemicals. The HLW will be converted to glass in themore » HLW vitrification facility for ultimate disposal at an offsite federal repository. At least a portion (~35%) of the LAW will be converted to glass in the LAW vitrification facility and will be disposed of onsite at the Integrated Disposal Facility (IDF). The pretreatment and HLW vitrification facilities will have the capacity to treat and immobilize the wastes destined for each facility. However, a second facility will be needed for the expected volume of additional LAW requiring immobilization. A cementitious waste form known as Cast Stone is being considered to provide the required additional LAW immobilization capacity. The Cast Stone waste form must be acceptable for disposal in the IDF. The Cast Stone waste form and immobilization process must be tested to demonstrate that the final Cast Stone waste form can comply with waste acceptance criteria for the IDF disposal facility and that the immobilization processes can be controlled to consistently provide an acceptable waste form product. Further, the waste form must be tested to provide the technical basis for understanding the long term performance of the waste form in the IDF disposal environment. These waste form performance data are needed to support risk assessment and performance assessment (PA) analyses of the long-term environmental impact of the waste disposal in the IDF. A testing program was developed in fiscal year (FY) 2012 describing in some detail the work needed to develop and qualify Cast Stone as a waste form for the solidification of Hanford LAW (Westsik et al. 2012). Included within Westsik et al. (2012) is a section on the near-term needs to address Tri-Party Agreement Milestone M-062-40ZZ. The objectives of the testing program to be conducted in FY 2013 and FY 2014 are to: • Determine an acceptable formulation for the LAW Cast Stone waste form. • Evaluate sources of dry materials for preparing the LAW Cast Stone. • Demonstrate the robustness of the Cast Stone waste form for a range of LAW compositions. • Demonstrate the robustness of the formulation for variability in the Cast Stone process. • Provide Cast Stone contaminant release data for PA and risk assessment evaluations. The first step in determining an acceptable formulation for the LAW Cast Stone waste form is to conduct screening tests to examine expected ranges in pretreated LAW composition, waste stream concentrations, dry-materials sources, and mix ratios of waste feed to dry blend. A statistically designed test matrix will be used to evaluate the effects of these key parameters on the properties of the Cast Stone as it is initially prepared and after curing. The second phase of testing will focus on selection of a baseline Cast Stone formulation for LAW and demonstrating that Cast Stone can meet expected waste form requirements for disposal in the IDF. It is expected that this testing will use the results of the screening tests to define a smaller suite of tests to refine the composition of the baseline Cast Stone formulation (e.g. waste concentration, water to dry mix ratio, waste loading).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2009-07-29
In 1999, the Nuclear Nuclear Security Administration (NNSA) signed a contract with a consortium, now called Shaw AREVA MOX Services, LLC to design, build, and operate a Mixed Oxide (MOX) Fuel Fabrication Facility. This facility will be a major component in the United States program to dispose of surplus weapon-grade plutonium. The facility will take surplus weapon-grade plutonium, remove impurities, and mix it with uranium oxide to form MOX fuel pellets for reactor fuel assemblies. These assemblies will be irradiated in commercial nuclear power reactors.
None
2018-01-16
In 1999, the Nuclear Nuclear Security Administration (NNSA) signed a contract with a consortium, now called Shaw AREVA MOX Services, LLC to design, build, and operate a Mixed Oxide (MOX) Fuel Fabrication Facility. This facility will be a major component in the United States program to dispose of surplus weapon-grade plutonium. The facility will take surplus weapon-grade plutonium, remove impurities, and mix it with uranium oxide to form MOX fuel pellets for reactor fuel assemblies. These assemblies will be irradiated in commercial nuclear power reactors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neupauer, R.M.; Thurmond, S.M.
This report contains health and safety information relating to the chemicals that have been identified in the mixed waste streams at the Waste Treatment Facility at the Idaho National Engineering Laboratory. Information is summarized in two summary sections--one for health considerations and one for safety considerations. Detailed health and safety information is presented in material safety data sheets (MSDSs) for each chemical.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neupauer, R.M.; Thurmond, S.M.
This report contains health and safety information relating to the chemicals that have been identified in the mixed waste streams at the Waste Treatment Facility at the Idaho National Engineering Laboratory. Information is summarized in two summary sections--one for health considerations and one for safety considerations. Detailed health and safety information is presented in material safety data sheets (MSDSs) for each chemical.
A numerical study of mixing and combustion in hypervelocity flows through a scramjet combustor model
NASA Technical Reports Server (NTRS)
Krishamurthy, Ramesh
1993-01-01
Interest in high speed, air-breathing propulsion systems such as scramjets has revived in recent years fueled to a large extent by the National Aerospace Plane (NASP) program. These vehicles are expected to fly trans-atmospheric and as a consequence, the Mach number level within the engine/combustor would be rather high (M greater than 5). Ground based testing of such scramjet engines requires a facility that can not only achieve the right Mach number, but also have the proper pressures and temperatures to simulate the combustion processes. At present, only pulse type facilities can provide such high enthalpy flows. The newest of these is the free-piston shock tunnel, T5 located at GALCIT. Recently, a generic combustor model was tested in T5, and the experimental data from that study is analyzed in the present report. The available experimental data from T5 are essentially the static pressures on the injection wall and the one opposite to it. Thus, a principal aim of the present study was to validate the available experimental data by using a proven CFD tool and then investigate the performance characteristics of the combustor model, such as, the mixing efficiency and combustion efficiency. For this purpose, in this study, the code GASP has been used.
A numerical study of mixing and combustion in hypervelocity flows through a scramjet combustor model
NASA Astrophysics Data System (ADS)
Krishamurthy, Ramesh
1993-12-01
Interest in high speed, air-breathing propulsion systems such as scramjets has revived in recent years fueled to a large extent by the National Aerospace Plane (NASP) program. These vehicles are expected to fly trans-atmospheric and as a consequence, the Mach number level within the engine/combustor would be rather high (M greater than 5). Ground based testing of such scramjet engines requires a facility that can not only achieve the right Mach number, but also have the proper pressures and temperatures to simulate the combustion processes. At present, only pulse type facilities can provide such high enthalpy flows. The newest of these is the free-piston shock tunnel, T5 located at GALCIT. Recently, a generic combustor model was tested in T5, and the experimental data from that study is analyzed in the present report. The available experimental data from T5 are essentially the static pressures on the injection wall and the one opposite to it. Thus, a principal aim of the present study was to validate the available experimental data by using a proven CFD tool and then investigate the performance characteristics of the combustor model, such as, the mixing efficiency and combustion efficiency. For this purpose, in this study, the code GASP has been used.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fuehne, David Patrick; Lattin, Rebecca Renee
The Rad-NESHAP program, part of the Air Quality Compliance team of LANL’s Compliance Programs group (EPC-CP), and the Radiation Instrumentation & Calibration team, part of the Radiation Protection Services group (RP-SVS), frequently partner on issues relating to characterizing air flow streams. This memo documents the most recent example of this partnership, involving performance testing of sulfur hexafluoride detectors for use in stack gas mixing tests. Additionally, members of the Rad-NESHAP program performed a functional trending test on a pair of optical particle counters, comparing results from a non-calibrated instrument to a calibrated instrument. Prior to commissioning a new stack samplingmore » system, the ANSI Standard for stack sampling requires that the stack sample location must meet several criteria, including uniformity of tracer gas and aerosol mixing in the air stream. For these mix tests, tracer media (sulfur hexafluoride gas or liquid oil aerosol particles) are injected into the stack air stream and the resulting air concentrations are measured across the plane of the stack at the proposed sampling location. The coefficient of variation of these media concentrations must be under 20% when evaluated over the central 2/3 area of the stack or duct. The instruments which measure these air concentrations must be tested prior to the stack tests in order to ensure their linear response to varying air concentrations of either tracer gas or tracer aerosol. The instruments used in tracer gas and aerosol mix testing cannot be calibrated by the LANL Standards and Calibration Laboratory, so they would normally be sent off-site for factory calibration by the vendor. Operational requirements can prevent formal factory calibration of some instruments after they have been used in hazardous settings, e.g., within a radiological facility with potential airborne contamination. The performance tests described in this document are intended to demonstrate the reliable performance of the test instruments for the specific tests used in stack flow characterization.« less
Facility and market factors affecting transitions from nursing home to community.
Arling, Greg; Abrahamson, Kathleen A; Cooke, Valerie; Kane, Robert L; Lewis, Teresa
2011-09-01
Research into nursing home transitions has given limited attention to the facility or community contexts. To identify facility and market factors affecting transitions of nursing home residents back to the community. Multilevel models were used to estimate effects of facility and market factors on facility-level community discharge rates after controlling for resident demographic, health, and functional conditions. Facility discharge rates were adjusted using Empirical Bayes estimation. Annual cohort of first-time admissions (N=24,648) to 378 Minnesota nursing facilities in 75 nursing home markets from July 2005 to June 2006. Community discharge within 90 days of admission; facility occupancy, payer mix, ownership, case-mix acuity, size, admissions from hospitals, nurse staffing level, and proportion of admissions preferring or having support to return to the community; and nursing market population size, average occupancy, market concentration, and availability of home and community-based services. Rates of community discharge (Empirical Bayes residual) were highest in facilities with more residents preferring community discharge, more Medicare days, higher nurse staffing levels, and higher occupancy. In addition, facilities had higher community discharge rates if they were located in markets with a greater ratio of home and community-based services recipients to nursing home residents and with larger populations. State Medicaid programs should undertake system-level interventions that encourage nursing facilities to reduce unused bed capacity, balance the mix of payers, invest in nurse staffing, and take other steps to promote community discharges. In addition, states should increase home and community-based services, particularly in markets with low community discharge rates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This is document addresses the Federal regulations governing the closure of hazardous and mixed waste units subject to Resource Conservation and Recovery Act (RCRA) requirements. It provides a brief overview of the RCRA permitting program and the extensive RCRA facility design and operating standards. It provides detailed guidance on the procedural requirements for closure and post-closure care of hazardous and mixed waste management units, including guidance on the preparation of closure and post-closure plans that must be submitted with facility permit applications. This document also provides guidance on technical activities that must be conducted both during and after closure ofmore » each of the following hazardous waste management units regulated under RCRA.« less
1998 report on Hanford Site land disposal restrictions for mixed waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Black, D.G.
1998-04-10
This report was submitted to meet the requirements of Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) Milestone M-26-01H. This milestone requires the preparation of an annual report that covers characterization, treatment, storage, minimization, and other aspects of managing land-disposal-restricted mixed waste at the Hanford Facility. The US Department of Energy, its predecessors, and contractors on the Hanford Facility were involved in the production and purification of nuclear defense materials from the early 1940s to the late 1980s. These production activities have generated large quantities of liquid and solid mixed waste. This waste is regulated under authority of bothmore » the Resource Conservation and Recovery Act of l976 and the Atomic Energy Act of 1954. This report covers only mixed waste. The Washington State Department of Ecology, US Environmental Protection Agency, and US Department of Energy have entered into the Tri-Party Agreement to bring the Hanford Facility operations into compliance with dangerous waste regulations. The Tri-Party Agreement required development of the original land disposal restrictions (LDR) plan and its annual updates to comply with LDR requirements for mixed waste. This report is the eighth update of the plan first issued in 1990. The Tri-Party Agreement requires and the baseline plan and annual update reports provide the following information: (1) Waste Characterization Information -- Provides information about characterizing each LDR mixed waste stream. The sampling and analysis methods and protocols, past characterization results, and, where available, a schedule for providing the characterization information are discussed. (2) Storage Data -- Identifies and describes the mixed waste on the Hanford Facility. Storage data include the Resource Conservation and Recovery Act of 1976 dangerous waste codes, generator process knowledge needed to identify the waste and to make LDR determinations, quantities stored, generation rates, location and method of storage, an assessment of storage-unit compliance status, storage capacity, and the bases and assumptions used in making the estimates.« less
CONCEPTUAL DESIGN ASSESSMENT FOR THE CO-FIRING OF BIO-REFINERY SUPPLIED LIGNIN PROJECT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ted Berglund; Jeffrey T. Ranney; Carol L. Babb
2002-04-01
The major aspects of this project are proceeding toward completion. Prior to this quarter, design criteria, tentative site selection, facility layout, and preliminary facility cost estimates were completed and issued. Processing of bio-solids was completed, providing material for the pilot operations. Pilot facility hydrolysis production has been completed to produce lignin for co-fire testing and the lignin fuel was washed and dewatered. Both the lignin and bio-solids fuel materials for co-fire testing were sent to the co-fire facility (EERC) for evaluation and co-firing. EERC has received coal typical of the fuel to the TVA-Colbert boilers. This material was used atmore » EERC as baseline material and for mixing with the bio-fuel for combustion testing. All the combustion and fuel handling tests at EERC have been completed. During fuel preparation EERC reported no difficulties in fuel blending and handling. Preliminary co-fire test results indicate that the blending of lignin and bio-solids with the Colbert coal blend generally reduces NO{sub x} emissions, increases the reactivity of the coal, and increases the ash deposition rate on superheater surfaces. Deposits produced from the fuel blends, however, are more friable and hence easier to remove from tube surfaces relative to those produced from the baseline Colbert coal blend. The final co-fire testing report is being prepared at EERC and will be completed by the end of the second quarter of 2002. The TVA-Colbert facility has neared completion of the task to evaluate co-location of the Masada facility on the operation of the power generation facility. The TVA-Colbert fossil plant is fully capable of providing a reliable steam supply. The preferred steam supply connection points and steam pipeline routing have been identified. The environmental review of the pipeline routing has been completed and no major impacts have been identified. Detailed assessment of steam export impacts on the Colbert boiler system have been completed and a cost estimate for the steam supply system was completed. The cost estimate and output and heat rate impacts have been used to determine a preliminary price for the exported steam. TVA is further evaluating the impacts of adding lignin to the coal fuel blend and how the steam cost is impacted by proximity of the Masada biomass facility.« less
The effect of state policies on nursing home resident outcomes.
Mor, Vincent; Gruneir, Andrea; Feng, Zhanlian; Grabowski, David C; Intrator, Orna; Zinn, Jacqueline
2011-01-01
To test the effect of changes in Medicaid reimbursement on clinical outcomes of long-stay nursing home (NH) residents. Longitudinal, retrospective study of NHs, merging aggregated resident-level quality measures with facility characteristics and state policy survey data. All free-standing NHs in urban counties with at least 20 long-stay residents per quarter (length of stay > 90 days) in the continental United States between 1999 and 2005. Long-stay NH residents Annual state Medicaid average per diem reimbursement and the presence of case-mix reimbursement in each year. Quarterly facility-aggregated, risk-adjusted quality-of-care measures surpassing a threshold for functional (activity of daily living) decline, physical restraint use, pressure ulcer incidence or worsening, and persistent pain. All outcomes showed an improvement trend over the study period, particularly physical restraint use. Facility fixed-effect regressions revealed that a $10 increase in Medicaid payment increased the likelihood of a NH meeting quality thresholds by 9% for functional decline, 5% for pain control, and 2% for pressure ulcers but not reduced use of physical restraints. Facilities in states that increased Medicaid payment most showed the greatest improvement in outcomes. The introduction of case-mix reimbursement was unrelated to quality improvement. Improvements in the clinical quality of NH care have been achieved, particularly where Medicaid payment has increased, generally from a lower baseline. Although this is a positive finding, challenges to implementing efficient reimbursement policies remain. © 2010, Copyright the Authors. Journal compilation © 2010, The American Geriatrics Society.
THE CONCEPTUAL DESIGN ASSESSMENT FOR THE CO-FIRING OF BIO-REFINERY SUPPLIED LIGNIN PROJECT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ted Berglund; Jeffrey T. Ranney; Carol L. Babb
2001-07-01
The major aspects of this project are proceeding toward completion. Prior to this quarter, design criteria, tentative site selection, facility layout, and preliminary facility cost estimates were completed and issued. Processing of bio-solids was completed, providing material for the pilot operations. Pilot facility design, equipment selection, and modification were completed during the fourth quarter of 2000. Initial pilot facility shakedown was completed during the fourth quarter. After some unavoidable delays, a suitable representative supply of MSW feed material was procured. During this first quarter of 2001, shredding of the feed material and final feed conditioning were completed. Pilot facility hydrolysismore » production was completed to produce lignin for co-fire testing. During this quarter, TVA completed the washing and dewatering of the lignin material produced from the MSW hydrolysis. Seven drums of lignin material were washed to recover the acid and sugar from the lignin and provide an improved fuel for steam generation. Samples of both the lignin and bio-solids fuel materials for co-fire testing were sent to the co-fire facility (EERC) for evaluation. After sample evaluation, EERC approved sending the material and all of the necessary fuel for testing was shipped to EERC. EERC has requested and will receive coal typical of the fuel to the TVA-Colbert boilers. This material will be used at EERC as baseline material and for mixing with the bio-fuel for combustion testing. EERC combustion testing of the bio based fuels is scheduled to begin in August of 2001. The TVA-Colbert facility has neared completion of the task to evaluate the co-location of the Masada facility on the operation of the power generation facility. The TVA-Colbert fossil plant is fully capable of providing a reliable steam supply. The preferred steam supply connection points and steam pipeline routing have been identified. The environmental review of the pipeline routing has been completed and no major impacts have been identified. Detailed assessment of steam export impacts on the Colbert boiler system have been completed and a cost estimate for steam supply system was completed. The cost estimate and the output and heat rate impacts will be used to determine a preliminary price for the exported steam. The preliminary steam price will be determined in the next quarter.« less
Misconceptions about case-mix payments for nursing homes.
Grimaldi, P L
1987-04-01
Despite the increasing use of case-mix payment systems for skilled and intermediate nursing home care (at least 10 state Medicaid programs have adopted or are considering adopting such a system), misconceptions about such systems still exist. Unless these inaccurate perceptions are corrected, a state may adopt a system that fails to realize its goals. Some of these misconceptions include the beliefs that case-mix payment systems: Apply to all nursing homes costs; Will benefit hospital-based facilities; Will resolve the access problems of heavy care public patients; Will result in higher statewide payment rates because patient characteristics are factored directly into the calculations. In fact, case-mix adjustments are applied only to costs that can be traced directly to patients' impairments. Nursing services and some ancillary services are dependent on case mix, while administrative and support services are largely independent of case mix. Capital costs usually can be ignored in formulating the case-mix adjustment. Although hospital-based facilities frequently have sicker patients than freestanding facilities, studies show that only a portion of the cost differential is explained by case-mix differences. In the case of heavy-care patients, some believe that case-mix payment systems will resolve access problems by paying higher rates in response to the higher treatment costs. Access may not improve, however, if the new rates are lower than those paid by comparable private patients. Perhaps a loosening in the certificate-of-need process will also be needed to resolve the access problem.(ABSTRACT TRUNCATED AT 250 WORDS)
Development of Eulerian Code Modeling for ICF Experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bradley, Paul A.
2014-02-27
One of the most pressing unexplained phenomena standing in the way of ICF ignition is understanding mix and how it interacts with burn. Experiments were being designed and fielded as part of the Defect-Induced Mix Experiment (DIME) project to obtain data about the extent of material mix and how this mix influenced burn. Experiments on the Omega laser and National Ignition Facility (NIF) provided detailed data for comparison to the Eulerian code RAGE1. The Omega experiments were able to resolve the mix and provide “proof of principle” support for subsequent NIF experiments, which were fielded from July 2012 through Junemore » 2013. The Omega shots were fired at least once per year between 2009 and 2012. RAGE was not originally designed to model inertial confinement fusion (ICF) implosions. It still lacks lasers, so the code has been validated using an energy source. To test RAGE, the simulation output is compared to data and by means of postprocessing tools that were developed. Here, the various postprocessing tools are described with illustrative examples.« less
Development and pilot testing of a mental healthcare plan in Nepal
Jordans, M. J. D.; Luitel, N. P.; Pokhrel, P.; Patel, V.
2016-01-01
Background Mental health service delivery models that are grounded in the local context are needed to address the substantial treatment gap in low- and middle-income countries. Aims To present the development, and content, of a mental healthcare plan (MHCP) in Nepal and assess initial feasibility. Method A mixed methods formative study was conducted. Routine monitoring and evaluation data, including client flow and reports of satisfaction, were obtained from patients (n = 135) during the pilot-testing phase in two health facilities. Results The resulting MHCP consists of 12 packages, divided over community, health facility and organisation platforms. Service implementation data support the real-life applicability of the MHCP, with reasonable treatment uptake. Key barriers were identified and addressed, namely dissatisfaction with privacy, perceived burden among health workers and high drop-out rates. Conclusions The MHCP follows a collaborative care model encompassing community and primary healthcare interventions. PMID:26447173
Development and pilot testing of a mental healthcare plan in Nepal.
Jordans, M J D; Luitel, N P; Pokhrel, P; Patel, V
2016-01-01
Mental health service delivery models that are grounded in the local context are needed to address the substantial treatment gap in low- and middle-income countries. To present the development, and content, of a mental healthcare plan (MHCP) in Nepal and assess initial feasibility. A mixed methods formative study was conducted. Routine monitoring and evaluation data, including client flow and reports of satisfaction, were obtained from patients (n = 135) during the pilot-testing phase in two health facilities. The resulting MHCP consists of 12 packages, divided over community, health facility and organisation platforms. Service implementation data support the real-life applicability of the MHCP, with reasonable treatment uptake. Key barriers were identified and addressed, namely dissatisfaction with privacy, perceived burden among health workers and high drop-out rates. The MHCP follows a collaborative care model encompassing community and primary healthcare interventions. © The Royal College of Psychiatrists 2016.
Some unresolved questions on hot-jet mixing control through artificial excitation
NASA Technical Reports Server (NTRS)
Ahuja, K. K.; Lepicovsky, J.; Brown, W. H.
1986-01-01
The problem of the mixing enhancement of heated jets through acoustic excitation is addressed using a 5.08 cm diameter jet operating at Mach numbers as high as 1.12 and at temperatures reaching 670 K. An experimental investigation is carried out to determine why high-speed heated jets are not as responsive to internal excitation as low-speed heated jets. Results are also presented which are related to the flow structure in the presence of screech and under the influence of external excitation. It is shown that, if sufficiently high excitation levels are used, the heated jets, even at high levels, can be modified by artificial excitation. Nonetheless, it is concluded that, for the test facility and test conditions used in the present study, the high-Mach-number heated jets are considerably less excitable than the similarly heated low-Mach-number jets.
NASA Technical Reports Server (NTRS)
Struk, Peter; Bartkus, Tadas; Tsao, Jen-Ching; Bencic, Timothy; King, Michael; Ratvasky, Thomas; Van Zante, Judith
2017-01-01
This presentation shows results from an initial study of the fundamental physics of ice-crystal ice accretion using the NASA Propulsion Systems Lab (PSL). Ice accretion due to the ingestion of ice-crystals is being attributed to numerous jet-engine power-loss events. The NASA PSL is an altitude jet-engine test facility which has recently added a capability to inject ice particles into the flow. NASA is evaluating whether this facility, in addition to full-engine and motor-driven-rig tests, can be used for more fundamental ice-accretion studies that simulate the different mixed-phase icing conditions along the core flow passage of a turbo-fan engine compressor. The data from such fundamental accretion tests will be used to help develop and validate models of the accretion process. The present study utilized a NACA0012 airfoil. The mixed-phase conditions were generated by partially freezing the liquid-water droplets ejected from the spray bars. This presentation shows data regarding (1) the freeze out characteristics of the cloud, (2) changes in aerothermal conditions due to the presence of the cloud, and (3) the ice accretion characteristics observed on the airfoil model. The primary variable in this test was the PSL plenum humidity which was systematically varied for two duct-exit-plane velocities (85 and 135 ms) as well as two particle size clouds (15 and 50 m MVDi). The observed clouds ranged from fully glaciated to fully liquid, where the liquid clouds were at least partially supercooled. The air total temperature decreased at the test section when the cloud was activated due to evaporation. The ice accretions observed ranged from sharp arrow-like accretions, characteristic of ice-crystal erosion, to cases with double-horn shapes, characteristic of supercooled water accretions.
NASA Technical Reports Server (NTRS)
Struk, Peter M.; Ratvasky, Thomas P.; Bencic, Timothy J.; Van Zante, Judith F.; King, Michael C.; Tsao, Jen-Ching; Bartkus, Tadas P.
2017-01-01
This paper presents results from an initial study of the fundamental physics of ice-crystal ice accretion using the NASA Propulsion Systems Lab (PSL). Ice accretion due to the ingestion of ice-crystals is being attributed to numerous jet-engine power-loss events. The NASA PSL is an altitude jet-engine test facility which has recently added a capability to inject ice particles into the flow. NASA is evaluating whether this facility, in addition to full-engine and motor-driven-rig tests, can be used for more fundamental ice-accretion studies that simulate the different mixed-phase icing conditions along the core flow passage of a turbo-fan engine compressor. The data from such fundamental accretion tests will be used to help develop and validate models of the accretion process. The present study utilized a NACA0012 airfoil. The mixed-phase conditions were generated by partially freezing the liquid-water droplets ejected from the spray bars. This paper presents data regarding (1) the freeze out characteristics of the cloud, (2) changes in aerothermal conditions due to the presence of the cloud, and (3) the ice accretion characteristics observed on the airfoil model. The primary variable in this test was the PSL plenum humidity which was systematically varied for two duct-exit-plane velocities (85 and 135 ms) as well as two particle size clouds (15 and 50 m MVDi). The observed clouds ranged from fully glaciated to fully liquid, where the liquid clouds were at least partially supercooled. The air total temperature decreased at the test section when the cloud was activated due to evaporation. The ice accretions observed ranged from sharp arrow-like accretions, characteristic of ice-crystal erosion, to cases with double-horn shapes, characteristic of supercooled water accretions.
Turan, Janet M.; Hatcher, Abigail H.; Medema-Wijnveen, José; Onono, Maricianah; Miller, Suellen; Bukusi, Elizabeth A.; Turan, Bulent; Cohen, Craig R.
2012-01-01
Background Childbirth with a skilled attendant is crucial for preventing maternal mortality and is an important opportunity for prevention of mother-to-child transmission of HIV. The Maternity in Migori and AIDS Stigma Study (MAMAS Study) is a prospective mixed-methods investigation conducted in a high HIV prevalence area in rural Kenya, in which we examined the role of women's perceptions of HIV-related stigma during pregnancy in their subsequent utilization of maternity services. Methods and Findings From 2007–2009, 1,777 pregnant women with unknown HIV status completed an interviewer-administered questionnaire assessing their perceptions of HIV-related stigma before being offered HIV testing during their first antenatal care visit. After the visit, a sub-sample of women was selected for follow-up (all women who tested HIV-positive or were not tested for HIV, and a random sample of HIV-negative women, n = 598); 411 (69%) were located and completed another questionnaire postpartum. Additional qualitative in-depth interviews with community health workers, childbearing women, and family members (n = 48) aided our interpretation of the quantitative findings and highlighted ways in which HIV-related stigma may influence birth decisions. Qualitative data revealed that health facility birth is commonly viewed as most appropriate for women with pregnancy complications, such as HIV. Thus, women delivering at health facilities face the risk of being labeled as HIV-positive in the community. Our quantitative data revealed that women with higher perceptions of HIV-related stigma (specifically those who held negative attitudes about persons living with HIV) at baseline were subsequently less likely to deliver in a health facility with a skilled attendant, even after adjusting for other known predictors of health facility delivery (adjusted odds ratio = 0.44, 95% CI 0.22–0.88). Conclusions Our findings point to the urgent need for interventions to reduce HIV-related stigma, not only for improving quality of life among persons living with HIV, but also for better health outcomes among all childbearing women and their families. Please see later in the article for the Editors' Summary. PMID:22927800
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-23
... MOX Services (Mixed Oxide Fuel Fabrication Facility); Notice of Atomic Safety and Licensing Board Reconstitution Pursuant to 10 CFR 2.313(c) and 2.321(b), the Atomic Safety and Licensing Board (Board) in the... Rockville, Maryland this 16th day of November 2012. E. Roy Hawkens, Chief Administrative Judge, Atomic...
RCRA Refresher Self-Study, Course 28582
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simpson, Lewis Edward
Federal and state regulations require hazardous and mixed waste facility workers at treatment and storage facilities (TSFs) and <90-day accumulation areas to be trained in hazardous and mixed waste management. This course will refamiliarize and update <90-day accumulation area workers, TSF workers, and supervisors of TSF workers regarding waste identification, pollution prevention, storage area requirements, emergency response procedures, and record-keeping requirements.
RCRA Personnel Training, Course 7488
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simpson, Lewis Edward
Federal and state regulations require hazardous and mixed waste facility workers at treatment and storage facilities (TSFs) and <90-day accumulation areas to be trained in hazardous and mixed waste management. This course will refamiliarize and update <90-day accumulation area workers, TSF workers, and supervisors of TSF workers regarding waste identification, pollution prevention, storage area requirements, emergency response procedures, and record-keeping requirements.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-09
... subparagraph (4)(b)4, relating to sulfur dioxide, to correct an error in the standard condition for temperature... subparagraph (b)5(i) to clarify the specific equipment covered by permit-by-rule for hot mix asphalt plants... million BtU per hour'' is replaced by ``hot mix asphalt facilities,'' to best describe the facilities...
MaRIE: an experimental facility concept revolutionizing materials in extremes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnes, Cris W
The Matter-Radiation Interactions in Extremes (MaRIE) project intends to create an experimental facility that will revolutionize the control of materials in extremes. That control extends to extreme regimes where solid material has failed and begins to flow - the regimes of fluid dynamics and turbulent mixing. This presentation introduces the MaRIE facility concept, demonstrates examples of the science case that determine its functional requirements, and kicks-off the discussion of the decadal scientific challenges of mixing in extremes, including those MaRIE might address.
NASA Technical Reports Server (NTRS)
Lezberg, Erwin A.; Metzler, Allen J.; Pack, William D.
1993-01-01
Results of in-stream combustion measurements taken during Mach 5 to 7 true simulation testing of the Hypersonic Research Engine/Aerothermodynamic Integration Model (HRE/AIM) are presented. These results, the instrumentation techniques, and configuration changes to the engine installation that were required to test this model are described. In test runs at facility Mach numbers of 5 to 7, an exhaust instrumentation ring which formed an extension of the engine exhaust nozzle shroud provided diagnostic measurements at 10 circumferential locations in the HRE combustor exit plane. The measurements included static and pitot pressures using conventional conical probes, combustion gas temperatures from cooled-gas pyrometer probes, and species concentration from analysis of combustion gas samples. Results showed considerable circumferential variation, indicating that efficiency losses were due to nonuniform fuel distribution or incomplete mixing. Results using the Mach 7 facility nozzle but with Mach 6 temperature simulation, 1590 to 1670 K, showed indications of incomplete combustion. Nitric oxide measurements at the combustor exit peaked at 2000 ppmv for stoichiometric combustion at Mach 6.
Davis, M A; Freeman, J W; Kirby, E C
1998-01-01
OBJECTIVE: To examine the effect of case mix-adjusted reimbursement policy and market factors on nursing home performance. DATA SOURCES AND STUDY SETTING: Data from Medicaid certification inspection surveys, Medicaid cost reports, and the Kentucky State Center for Health Statistics for the years 1989 and 1991, to examine changes in nursing home performance stemming from the adoption of case mix-adjusted reimbursement in 1990. STUDY DESIGN: In addition to cross-sectional regressions, a first-difference approach to fixed-effects regression analyses was employed to control for facility differences that were essentially fixed during the survey years and to estimate the effects of time-varying predictors on changes in facility expenditures, efficiency, and profitability. PRINCIPAL FINDINGS: Facilities that increased the proportion of Medicaid residents and eliminated excess capacity experienced higher profitability gains during the beginning phase of case-mix reimbursement. Having a heavy-care resident population was positively related to expenditures prior to reimbursement reform, and it was negatively related to expenditures after the case-mix reimbursement policy was introduced. While facility-level changes in case mix had no reliable influence on costs or profits, nursing homes showing an increased prevalence of poor-quality nursing practices exhibited increases in efficiency and profitability. At the market level, reductions in excess or empty nursing home beds were accompanied by a significant growth in home health services. Moreover, nursing homes located in markets with expanding home health services exhibited higher increases in costs per case-mix unit. CONCLUSIONS: Characteristics of the reimbursement system appear to reward a cost minimization orientation with potentially detrimental effects on quality of care. These effects, exacerbated by a supply-constrained market, may be mitigated by policies that encourage the expansion of home health service availability. PMID:9776938
Davis, M A; Freeman, J W; Kirby, E C
1998-10-01
To examine the effect of case mix-adjusted reimbursement policy and market factors on nursing home performance. Data from Medicaid certification inspection surveys, Medicaid cost reports, and the Kentucky State Center for Health Statistics for the years 1989 and 1991, to examine changes in nursing home performance stemming from the adoption of case mix-adjusted reimbursement in 1990. In addition to cross-sectional regressions, a first-difference approach to fixed-effects regression analyses was employed to control for facility differences that were essentially fixed during the survey years and to estimate the effects of time-varying predictors on changes in facility expenditures, efficiency, and profitability. Facilities that increased the proportion of Medicaid residents and eliminated excess capacity experienced higher profitability gains during the beginning phase of case-mix reimbursement. Having a heavy-care resident population was positively related to expenditures prior to reimbursement reform, and it was negatively related to expenditures after the case-mix reimbursement policy was introduced. While facility-level changes in case mix had no reliable influence on costs or profits, nursing homes showing an increased prevalence of poor-quality nursing practices exhibited increases in efficiency and profitability. At the market level, reductions in excess or empty nursing home beds were accompanied by a significant growth in home health services. Moreover, nursing homes located in markets with expanding home health services exhibited higher increases in costs per case-mix unit. Characteristics of the reimbursement system appear to reward a cost minimization orientation with potentially detrimental effects on quality of care. These effects, exacerbated by a supply-constrained market, may be mitigated by policies that encourage the expansion of home health service availability.
NASA Technical Reports Server (NTRS)
Allgood, Daniel C.; Graham, Jason S.; Ahuja, Vineet; Hosangadi, Ashvin
2010-01-01
Simulation technology can play an important role in rocket engine test facility design and development by assessing risks, providing analysis of dynamic pressure and thermal loads, identifying failure modes and predicting anomalous behavior of critical systems. Advanced numerical tools assume greater significance in supporting testing and design of high altitude testing facilities and plume induced testing environments of high thrust engines because of the greater inter-dependence and synergy in the functioning of the different sub-systems. This is especially true for facilities such as the proposed A-3 facility at NASA SSC because of a challenging operating envelope linked to variable throttle conditions at relatively low chamber pressures. Facility designs in this case will require a complex network of diffuser ducts, steam ejector trains, fast operating valves, cooling water systems and flow diverters that need to be characterized for steady state performance. In this paper, we will demonstrate with the use of CFD analyses s advanced capability to evaluate supersonic diffuser and steam ejector performance in a sub-scale A-3 facility at NASA Stennis Space Center (SSC) where extensive testing was performed. Furthermore, the focus in this paper relates to modeling of critical sub-systems and components used in facilities such as the A-3 facility. The work here will address deficiencies in empirical models and current CFD analyses that are used for design of supersonic diffusers/turning vanes/ejectors as well as analyses for confined plumes and venting processes. The primary areas that will be addressed are: (1) supersonic diffuser performance including analyses of thermal loads (2) accurate shock capturing in the diffuser duct; (3) effect of turning duct on the performance of the facility (4) prediction of mass flow rates and performance classification for steam ejectors (5) comparisons with test data from sub-scale diffuser testing and assessment of confidence levels in CFD based flowpath modeling of the facility. The analyses tools used here expand on the multi-element unstructured CFD which has been tailored and validated for impingement dynamics of dry plumes, complex valve/feed systems, and high pressure propellant delivery systems used in engine and component test stands at NASA SSC. The analyses performed in the evaluation of the sub-scale diffuser facility explored several important factors that influence modeling and understanding of facility operation such as (a) importance of modeling the facility with Real Gas approximation, (b) approximating the cluster of steam ejector nozzles as a single annular nozzle, (c) existence of mixed subsonic/supersonic flow downstream of the turning duct, and (d) inadequacy of two-equation turbulence models in predicting the correct pressurization in the turning duct and expansion of the second stage steam ejectors. The procedure used for modeling the facility was as follows: (i) The engine, test cell and first stage ejectors were simulated with an axisymmetric approximation (ii) the turning duct, second stage ejectors and the piping downstream of the second stage ejectors were analyzed with a three-dimensional simulation utilizing a half-plane symmetry approximation. The solution i.e. primitive variables such as pressure, velocity components, temperature and turbulence quantities were passed from the first computational domain and specified as a supersonic boundary condition for the second simulation. (iii) The third domain comprised of the exit diffuser and the region in the vicinity of the facility (primary included to get the correct shock structure at the exit of the facility and entrainment characteristics). The first set of simulations comprising the engine, test cell and first stage ejectors was carried out both as a turbulent real gas calculation as well as a turbulent perfect gas calculation. A comparison for the two cases (Real Turbulent and Perfect gas turbulent) of the Ma Number distribution and temperature distributions are shown in Figures 1 and 2 respectively.
Soma, Yuki; Tsunoda, Kenji; Kitano, Naruki; Jindo, Takashi; Tsuji, Taishi; Saghazadeh, Mahshid; Okura, Tomohiro
2017-03-01
To explore the relationships between the built environment and older adults' physical function. The present cross-sectional study carried out in 2010-2012 used data drawn from 509 community-dwelling older adults aged 65-86 years living in Kasama City, a Japanese rural region. We evaluated physical function with the following performance tests: grip strength, sit-to-stand, timed up & go and walking speed. Using geographic information systems, we measured population density and the number of destinations related to daily life, community centers, medical facilities and recreational facilities within participants' neighborhoods. After adjusting for potential confounders, we found lower population density was related to poor performance of sit-to-stand and walking speed in both sexes, and grip strength in women (trend P < 0.05). A lower number of daily life-related destinations was related to poor performance of sit-to-stand and walking speed in men, and grip strength and sit-to-stand in women. Similarly, the number of community centers was related to walking speed in both sexes. The number of medical and recreational facilities was also related to some physical performance in both sexes. A lower land use mix score, calculated by principal component analysis, was related to lower performance of sit-to-stand and walking speed in men, and grip strength and sit-to-stand in women. The present study suggests that, although there are some sex differences, low population density, land use mix, and fewer daily life-related destinations, community centers, medical facilities and recreational facilities are negative determinants of physical function. Geriatr Gerontol Int 2017; 17: 382-390. © 2016 Japan Geriatrics Society.
Assisted living and nursing homes: apples and oranges?
Zimmerman, Sheryl; Gruber-Baldini, Ann L; Sloane, Philip D; Eckert, J Kevin; Hebel, J Richard; Morgan, Leslie A; Stearns, Sally C; Wildfire, Judith; Magaziner, Jay; Chen, Cory; Konrad, Thomas R
2003-04-01
The goals of this study are to describe the current state of residential care/assisted living (RC/AL) care and residents in comparison with nursing home (NH) care and residents, identify different types of RC/AL care and residents, and consider how variation in RC/AL case-mix reflects differences in care provision and/or consumer preference. Data were derived from the Collaborative Studies of Long-Term Care, a four-state study of 193 RC/AL facilities and 40 NHs. Multivariate analyses examined differences in ten process of care measures between RC/AL facilities with less than 16 beds; traditional RC/AL with 16 or more beds; new-model RC/AL; and NHs. Generalized estimating equation models determined differences in resident case-mix across RC/AL facilities using data for 2,078 residents. NHs report provision of significantly more health services and have significantly more lenient admission policies than RC/AL facilities, but provide less privacy. They do not differ from larger RC/AL facilities in policy clarity or resident control. Differences within RC/AL types are evident, with smaller and for-profit facilities scoring lower than other facilities across multiple process measures, including those related to individual freedom and institutional order. Resident impairment is substantial in both NHs and RC/AL settings, but differs by RC/AL facility characteristics. Differences in process of care and resident characteristics by facility type highlight the importance of considering: (1) the adequacy of existing process measures for evaluating smaller facilities; (2) resident case-mix when comparing facility types and outcomes; and (3) the complexity of understanding the implication of the process of care, given the importance of person-environment fit. Work is continuing to clarify the role of RC/AL vis-à-vis NHs in our nation's system of residential long-term care.
Practice patterns, case mix, Medicare payment policy, and dialysis facility costs.
Hirth, R A; Held, P J; Orzol, S M; Dor, A
1999-01-01
OBJECTIVE: To evaluate the effects of case mix, practice patterns, features of the payment system, and facility characteristics on the cost of dialysis. DATA SOURCES/STUDY SETTING: The nationally representative sample of dialysis units in the 1991 U.S. Renal Data System's Case Mix Adequacy (CMA) Study. The CMA data were merged with data from Medicare Cost Reports, HCFA facility surveys, and HCFA's end-stage renal disease patient registry. STUDY DESIGN: We estimated a statistical cost function to examine the determinants of costs at the dialysis unit level. PRINCIPAL FINDINGS: The relationship between case mix and costs was generally weak. However, dialysis practices (type of dialysis membrane, membrane reuse policy, and treatment duration) did have a significant effect on costs. Further, facilities whose payment was constrained by HCFA's ceiling on the adjustment for area wage rates incurred higher costs than unconstrained facilities. The costs of hospital-based units were considerably higher than those of freestanding units. Among chain units, only members of one of the largest national chains exhibited significant cost savings relative to independent facilities. CONCLUSIONS: Little evidence showed that adjusting dialysis payment to account for differences in case mix across facilities would be necessary to ensure access to care for high-cost patients or to reimburse facilities equitably for their costs. However, current efforts to increase dose of dialysis may require higher payments. Longer treatments appear to be the most economical method of increasing the dose of dialysis. Switching to more expensive types of dialysis membranes was a more costly means of increasing dose and hence must be justified by benefits beyond those of higher dose. Reusing membranes saved money, but the savings were insufficient to offset the costs associated with using more expensive membranes. Most, but not all, of the higher costs observed in hospital-based units appear to reflect overhead cost allocation rather than a difference in real resources devoted to treatment. The economies experienced by the largest chains may provide an explanation for their recent growth in market share. The heterogeneity of results by chain size implies that characterizing units using a simple chain status indicator variable is inadequate. Cost differences by facility type and the effects of the ongoing growth of large chains are worthy of continued monitoring to inform both payment policy and antitrust enforcement. PMID:10029498
Practice patterns, case mix, Medicare payment policy, and dialysis facility costs.
Hirth, R A; Held, P J; Orzol, S M; Dor, A
1999-02-01
To evaluate the effects of case mix, practice patterns, features of the payment system, and facility characteristics on the cost of dialysis. The nationally representative sample of dialysis units in the 1991 U.S. Renal Data System's Case Mix Adequacy (CMA) Study. The CMA data were merged with data from Medicare Cost Reports, HCFA facility surveys, and HCFA's end-stage renal disease patient registry. We estimated a statistical cost function to examine the determinants of costs at the dialysis unit level. The relationship between case mix and costs was generally weak. However, dialysis practices (type of dialysis membrane, membrane reuse policy, and treatment duration) did have a significant effect on costs. Further, facilities whose payment was constrained by HCFA's ceiling on the adjustment for area wage rates incurred higher costs than unconstrained facilities. The costs of hospital-based units were considerably higher than those of freestanding units. Among chain units, only members of one of the largest national chains exhibited significant cost savings relative to independent facilities. Little evidence showed that adjusting dialysis payment to account for differences in case mix across facilities would be necessary to ensure access to care for high-cost patients or to reimburse facilities equitably for their costs. However, current efforts to increase dose of dialysis may require higher payments. Longer treatments appear to be the most economical method of increasing the dose of dialysis. Switching to more expensive types of dialysis membranes was a more costly means of increasing dose and hence must be justified by benefits beyond those of higher dose. Reusing membranes saved money, but the savings were insufficient to offset the costs associated with using more expensive membranes. Most, but not all, of the higher costs observed in hospital-based units appear to reflect overhead cost allocation rather than a difference in real resources devoted to treatment. The economies experienced by the largest chains may provide an explanation for their recent growth in market share. The heterogeneity of results by chain size implies that characterizing units using a simple chain status indicator variable is inadequate. Cost differences by facility type and the effects of the ongoing growth of large chains are worthy of continued monitoring to inform both payment policy and antitrust enforcement.
ERIC Educational Resources Information Center
Weidner, Theodore J.
2008-01-01
In 2002, APPA published "Maintenance Staffing Guidelines for Educational Facilities," the first building maintenance trades staffing guideline designed to assist educational facilities professionals with their staffing needs. addresses how facilities professionals can determine the appropriate size and mix of their organization. Contents…
An optimum organizational structure for a large earth-orbiting multidisciplinary Space Base
NASA Technical Reports Server (NTRS)
Ragusa, J. M.
1973-01-01
The purpose of this exploratory study was to identify an optimum hypothetical organizational structure for a large earth-orbiting multidisciplinary research and applications (R&A) Space Base manned by a mixed crew of technologists. Since such a facility does not presently exist, in situ empirical testing was not possible. Study activity was, therefore, concerned with the identification of a desired organizational structural model rather than the empirical testing of it. The essential finding of this research was that a four-level project type 'total matrix' model will optimize the efficiency and effectiveness of Space Base technologists.
NASA Technical Reports Server (NTRS)
Drozda, Tomasz G.; Shenoy, Rajiv R.; Passe, Bradley J.; Baurle, Robert A.; Drummond, J. Philip
2017-01-01
In order to reduce the cost and complexity associated with fuel injection and mixing experiments for high-speed flows, and to further enable optical access to the test section for nonintrusive diagnostics, the Enhanced Injection and Mixing Project (EIMP) utilizes an open flat plate configuration to characterize inert mixing properties of various fuel injectors for hypervelocity applications. The experiments also utilize reduced total temperature conditions to alleviate the need for hardware cooling. The use of "cold" flows and non-reacting mixtures for mixing experiments is not new, and has been extensively utilized as a screening technique for scramjet fuel injectors. The impact of reduced facility-air total temperature, and the use of inert fuel simulants, such as helium, on the mixing character of the flow has been assessed in previous numerical studies by the authors. Mixing performance was characterized for three different injectors: a strut, a ramp, and a flushwall. The present study focuses on the impact of using an open plate to approximate mixing in the duct. Toward this end, Reynolds-averaged simulations (RAS) were performed for the three fuel injectors in an open plate configuration and in a duct. The mixing parameters of interest, such as mixing efficiency and total pressure recovery, are then computed and compared for the two configurations. In addition to mixing efficiency and total pressure recovery, the combustion efficiency and thrust potential are also computed for the reacting simulations.
Carbonero, A; Guzmán, L T; García-Bocanegra, I; Borge, C; Adaszek, L; Arenas, A; Saa, L R
2018-01-01
An extensive cross-sectional study to determine the seroprevalence of and associated risk factors for Brucella infection was performed in dairy and mixed (dairy-beef) cattle herds in Ecuador. A total of 2666 serum samples from 386 farms were analyzed using Rose Bengal test and a blocking ELISA test. In addition, a questionnaire with 57 variables related to management, feeding, facilities, biosecurity, and animal health was filled in every cattle farm. A Generalized Estimating Equations model was used to determine the factors associated with Brucella seropositivity. The true prevalence of Brucella seropositivity in dairy and mixed cattle from Ecuador reached 17.0% (CI95% 15.6-18.4%). The herd prevalence was 45.1% (174/386) (CI95% 40.1-50.1%), and the within-herd prevalence ranged from 10 to 100% (mean 38.9%; Q1 14.3%, Q2 26.8%, Q3 52.5%). Seven factors were included in the GEE model for Brucella seropositivity: the nominal variables sex (OR 2.03; CI95% 1.32-3.13), herd type (dairy) (OR 1.79; CI95% 1.11-2.87), closed facilities in the farm (OR 1.80; CI95% 1.19-2.74), and ad libitum feeding (OR: 0.32; CI95%: 0.19-0.54), and the quantitative variables age (OR 1.005; CI95% 1.001-1.009), average slope in the farm (%) (OR 1.013; CI95% 1.002-1.024), and annual abortion rate (OR 1.016; CI95% 1.002-1.031). This study remarks the high spread of Brucella infection in cattle farms from Ecuador. In addition, it reports the risk factors associated to this infection in the predominant extensive system existent in this country.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manera, Annalisa; Corradini, Michael; Petrov, Victor
This project has been focused on the experimental and numerical investigations of the water-cooled and air-cooled Reactor Cavity Cooling System (RCCS) designs. At this aim, we have leveraged an existing experimental facility at the University of Wisconsin-Madison (UW), and we have designed and built a separate effect test facility at the University of Michigan. The experimental facility at UW has underwent several upgrades, including the installation of advanced instrumentation (i.e. wire-mesh sensors) built at the University of Michigan. These provides highresolution time-resolved measurements of the void-fraction distribution in the risers of the water-cooled RCCS facility. A phenomenological model has beenmore » developed to assess the water cooled RCCS system stability and determine the root cause behind the oscillatory behavior that occurs under normal two-phase operation. Testing under various perturbations to the water-cooled RCCS facility have resulted in changes in the stability of the integral system. In particular, the effects on stability of inlet orifices, water tank volume have and system pressure been investigated. MELCOR was used as a predictive tool when performing inlet orificing tests and was able to capture the Density Wave Oscillations (DWOs) that occurred upon reaching saturation in the risers. The experimental and numerical results have then been used to provide RCCS design recommendations. The experimental facility built at the University of Michigan was aimed at the investigation of mixing in the upper plenum of the air-cooled RCCS design. The facility has been equipped with state-of-theart high-resolution instrumentation to achieve so-called CFD grade experiments, that can be used for the validation of Computational Fluid Dynanmics (CFD) models, both RANS (Reynold-Averaged) and LES (Large Eddy Simulations). The effect of risers penetration in the upper plenum has been investigated as well.« less
Energy index decomposition methodology at the plant level
NASA Astrophysics Data System (ADS)
Kumphai, Wisit
Scope and method of study. The dissertation explores the use of a high level energy intensity index as a facility-level energy performance monitoring indicator with a goal of developing a methodology for an economically based energy performance monitoring system that incorporates production information. The performance measure closely monitors energy usage, production quantity, and product mix and determines the production efficiency as a part of an ongoing process that would enable facility managers to keep track of and, in the future, be able to predict when to perform a recommissioning process. The study focuses on the use of the index decomposition methodology and explored several high level (industry, sector, and country levels) energy utilization indexes, namely, Additive Log Mean Divisia, Multiplicative Log Mean Divisia, and Additive Refined Laspeyres. One level of index decomposition is performed. The indexes are decomposed into Intensity and Product mix effects. These indexes are tested on a flow shop brick manufacturing plant model in three different climates in the United States. The indexes obtained are analyzed by fitting an ARIMA model and testing for dependency between the two decomposed indexes. Findings and conclusions. The results concluded that the Additive Refined Laspeyres index decomposition methodology is suitable to use on a flow shop, non air conditioned production environment as an energy performance monitoring indicator. It is likely that this research can be further expanded in to predicting when to perform a recommissioning process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NSTec Environmental Management
The proposed Mixed Waste Storage Unit (MWSU) will be located within the Area 5 Radioactive Waste Management Complex (RWMC). Existing facilities at the RWMC will be used to store low-level mixed waste (LLMW). Storage is required to accommodate offsite-generated LLMW shipped to the Nevada Test Site (NTS) for disposal in the new Mixed Waste Disposal Unit (MWDU) currently in the design/build stage. LLMW generated at the NTS (onsite) is currently stored on the Transuranic (TRU) Pad (TP) in Area 5 under a Mutual Consent Agreement (MCA) with the Nevada Division of Environmental Protection, Bureau of Federal Facilities (NDEP/BFF). When themore » proposed MWSU is permitted, the U.S. Department of Energy (DOE) will ask that NDEP revoke the MCA and onsite-generated LLMW will fall under the MWSU permit terms and conditions. The unit will also store polychlorinated biphenyl (PCB) waste and friable and non-friable asbestos waste that meets the acceptance criteria in the Waste Analysis Plan (Exhibit 2) for disposal in the MWDU. In addition to Resource Conservation and Recovery Act (RCRA) requirements, the proposed MWSU will also be subject to Department of Energy (DOE) orders and other applicable state and federal regulations. Table 1 provides the metric conversion factors used in this application. Table 2 provides a list of existing permits. Table 3 lists operational RCRA units at the NTS and their respective regulatory status.« less
Atafu, Asmamaw; Kwon, Soonman
2018-05-20
Since 2010, the Ethiopian government introduced different measures to implement community-based health insurance (CBHI) schemes to improve access to health service and reduce the catastrophic effect of health care costs. The aim of this study was to examine the determinants of enrollment in CBHI in Northwest Ethiopia. In this study, we utilized a mix of quantitative (multivariate logistic regression applied to population survey linked with health facility survey) and qualitative (focus group discussion and in-depth interview) methods to better understand the factors that affect CBHI enrollment. The study revealed important factors, such as household, informal association, and health facility, as barriers to CBHI enrollment. Age and educational status, self-rated health status, perceived quality of health services, knowledge, and information (awareness) about CBHI were among the characteristics of individual household head, affecting enrollment. Household size and participation in an informal association, such as local credit associations, were also positively associated with CBHI enrollment. Additionally, health facility factors like unavailability of laboratory tests were the main factor that hinders CBHI enrollment. This study showed a possibility of adverse selection in CBHI enrollment. Additionally, perceived quality of health services, knowledge, and information (awareness) are positively associated with CBHI enrollment. Therefore, policy interventions to mitigate adverse selection as well as provision of social marketing activities are crucial to increase enrollment in CBHI. Furthermore, policy interventions that enhance the capacity of health facilities and schemes to provide the promised services are necessary. Copyright © 2018 John Wiley & Sons, Ltd.
Code of Federal Regulations, 2010 CFR
2010-01-01
... ADMINISTRATION CENTRAL LIQUIDITY FACILITY § 725.1 Scope. This part contains the regulations implementing the National Credit Union Central Liquidity Facility Act, subchapter III of the Federal Credit Union Act. The National Credit Union Administration Central Liquidity Facility is a mixed-ownership Government corporation...
Unpacking the enabling factors for hand, cord and birth-surface hygiene in Zanzibar maternity units
Gon, Giorgia; Ali, Said M; Towriss, Catriona; Kahabuka, Catherine; Ali, Ali O; Cavill, Sue; Dahoma, Mohammed; Faulkner, Sally; Haji, Haji S; Kabole, Ibrahim; Morrison, Emma; Said, Rukaiya M; Tajo, Amour; Velleman, Yael; Woodd, Susannah L; Graham, and Wendy J
2017-01-01
Abstract Recent national surveys in The United Republic of Tanzania have revealed poor standards of hygiene at birth in facilities. As more women opt for institutional delivery, improving basic hygiene becomes an essential part of preventative strategies for reducing puerperal and newborn sepsis. Our collaborative research in Zanzibar provides an in-depth picture of the state of hygiene on maternity wards to inform action. Hygiene was assessed in 2014 across all 37 facilities with a maternity unit in Zanzibar. We used a mixed methods approach, including structured and semi-structured interviews, and environmental microbiology. Data were analysed according to the WHO ‘cleans’ framework, focusing on the fundamental practices for prevention of newborn and maternal sepsis. For each ‘clean’ we explored the following enabling factors: knowledge, infrastructure (including equipment), staffing levels and policies. Composite indices were constructed for the enabling factors of the ‘cleans’ from the quantitative data: clean hands, cord cutting, and birth surface. Results from the qualitative tools were used to complement this information. Only 49% of facilities had the ‘infrastructural’ requirements to enable ‘clean hands’, with the availability of constant running water particularly lacking. Less than half (46%) of facilities met the ‘knowledge’ requirements for ensuring a ‘clean delivery surface’; six out of seven facilities had birthing surfaces that tested positive for multiple potential pathogens. Almost two thirds of facilities met the ‘infrastructure (equipment) requirement’ for ‘clean cord’; however, disposable cord clamps being frequently out of stock, often resulted in the use of non-sterile thread made of fabric. This mixed methods approach, and the analytical framework based on the WHO ‘cleans’ and the enabling factors, yielded practical information of direct relevance to action at local and ministerial levels. The same approach could be applied to collect and analyse data on infection prevention from maternity units in other contexts. PMID:28931118
Atmospheric ammonia mixing ratios at an open-air cattle feeding facility.
Hiranuma, Naruki; Brooks, Sarah D; Thornton, Daniel C O; Auvermann, Brent W
2010-02-01
Mixing ratios of total and gaseous ammonia were measured at an open-air cattle feeding facility in the Texas Panhandle in the summers of 2007 and 2008. Samples were collected at the nominally upwind and downwind edges of the facility. In 2008, a series of far-field samples was also collected 3.5 km north of the facility. Ammonium concentrations were determined by two complementary laboratory methods, a novel application of visible spectrophotometry and standard ion chromatography (IC). Results of the two techniques agreed very well, and spectrophotometry is faster, easier, and cheaper than chromatography. Ammonia mixing ratios measured at the immediate downwind site were drastically higher (approximately 2900 parts per billion by volume [ppbv]) than thos measured at the upwind site (< or = 200 ppbv). In contrast, at 3.5 km away from the facility, ammonia mixing ratios were reduced to levels similar to the upwind site (< or = 200 ppbv). In addition, PM10 (particulate matter < 10 microm in optical diameter) concentrations obtained at each sampling location using Grimm portable aerosol spectrometers are reported. Time-averaged (1-hr) volume concentrations of PM10 approached 5 x 10(12) nm3 cm(-3). Emitted ammonia remained largely in the gas phase at the downwind and far-field locations. No clear correlation between concentrations of ammonia and particles was observed. Overall, this study provides a better understanding of ammonia emissions from open-air animal feeding operations, especially under the hot and dry conditions present during these measurements.
Miscibility comparison for three refrigerant mixtures and four component refrigerants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kang, H.M.; Pate, M.B.
1999-07-01
Miscibility data were taken and compared for seven different refrigerants when mixed with the same polyol ester (POE) lubricant. Four of the seven refrigerants were single-component refrigerants while three of the refrigerants were mixtures composed of various combinations of the pure refrigerants. The purpose of this research was to investigate the difference in miscibility characteristics between refrigerant mixtures and their respective component refrigerants. The POE lubricant was a penta erythritol mixed-acid type POE which has a viscosity ISO32. The four pure refrigerants were R-32, R-125, R-134a, and R-143a and the three refrigerant mixtures were R-404A, R407C, and R-410A. The miscibilitymore » tests were performed in a test facility consisting of a series of miniature test cells submerged in a constant temperature bath. The test cells were constructed to allow for complete visibility of the refrigerant/lubricant mixtures under all test conditions. The tests were performed over a concentration range of 0 to 100% and a temperature range of {minus}40 to 194 F. The miscibility test results for refrigerant mixtures are compared to component refrigerants. In all cases, the refrigerant mixtures appear to have better miscibility than their most immiscible pure component.« less
42 CFR 413.184 - Payment exception: Pediatric patient mix.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 2 2014-10-01 2014-10-01 false Payment exception: Pediatric patient mix. 413.184... patient mix. (a) Qualifications. To qualify for an exception to its prospective payment rate based on its pediatric patient mix a facility must demonstrate that— (1) At least 50 percent of its patients are...
42 CFR 413.184 - Payment exception: Pediatric patient mix.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 2 2011-10-01 2011-10-01 false Payment exception: Pediatric patient mix. 413.184... patient mix. (a) Qualifications. To qualify for an exception to its prospective payment rate based on its pediatric patient mix a facility must demonstrate that— (1) At least 50 percent of its patients are...
42 CFR 413.184 - Payment exception: Pediatric patient mix.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 2 2013-10-01 2013-10-01 false Payment exception: Pediatric patient mix. 413.184... patient mix. (a) Qualifications. To qualify for an exception to its prospective payment rate based on its pediatric patient mix a facility must demonstrate that— (1) At least 50 percent of its patients are...
42 CFR 413.184 - Payment exception: Pediatric patient mix.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 2 2012-10-01 2012-10-01 false Payment exception: Pediatric patient mix. 413.184... patient mix. (a) Qualifications. To qualify for an exception to its prospective payment rate based on its pediatric patient mix a facility must demonstrate that— (1) At least 50 percent of its patients are...
75 FR 81250 - Pulse Jet Mixing at the Waste Treatment and Immobilization Plant
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-27
... DEFENSE NUCLEAR FACILITIES SAFETY BOARD [Recommendation 2010-2] Pulse Jet Mixing at the Waste... Board has made a recommendation to the Secretary of Energy concerning the use of pulse jet mixing at the..., 2010. Peter S. Winokur, Chairman. Recommendation 2010-2 to the Secretary of Energy Pulse Jet Mixing at...
Daboer, J C; Lar, L A; Afolaranmi, T O; Bupwatda, P W; Dani, N
2013-12-01
After the initial gains in Tuberculosis case detection and cure rates, progress became stunted by persisting constraints and challenges in the implementation of the Directly Observed Treatment Short course strategy. This prompted the Stop Tuberculosis partners in 2006 to adopt innovative approaches including the Public-Private Mix, to improve access to and quality of care. This paper assesses the level of Public-Private Mix in Tuberculosis control in Jos, Plateau State. This was a facility-based, cross sectional study where data from all consenting private health care facilities owned by medically trained personnel and private medical practitioners in Jos North and Jos South Local Government Areas was collected using structured questionnaires. Eight (47.1%) of all 17 facilities assessed gave anti Tuberculosis drugs on clinical suspicion of Tuberculosis, 5(29.4%) required Acid Fast Bacillus result and 3(17.6%) referred elsewhere for the Tuberculosis management. Only 6 facilities (35.3%) were microscopy, treatment centres, or both. Ten (58.8%) of the facilities had the Directly Observed Treatment Short course guidelines, but these could be sighted in only 5 (29.4%), while six (35.3%) had Tuberculosis record and referral forms. In 13 (76.5%) of the facilities, no local government Tuberculosis and Leprosy supervisors had ever visited them. Only 30 (57.7%) medical practitioners had access to the Directly Observed Treatment Short course. Thirty two (61.5%) respondents treated Tuberculosis according to the Directly Observed Treatment Short course strategy, but 19 (36.5%) still used the conventional method. Only 22(42.3%) practitioners had ever received any training on the Directly Observed Treatment Short course strategy. The level of Public-Private Mix in Tuberculosis control in Jos is low.
Conducting Closed Habitation Experiments: Experience from the Lunar Mars Life Support Test Project
NASA Technical Reports Server (NTRS)
Barta, Daniel J.; Edeen, Marybeth A.; Henninger, Donald L.
2004-01-01
The Lunar-Mars Life Support Test Project (LMLSTP) was conducted from 1995 through 1997 at the National Aeronautics and Space Administration s (NASA) Johnson Space Center (JSC) to demonstrate increasingly longer duration operation of integrated, closed-loop life support systems that employed biological and physicochemical techniques for water recycling, waste processing, air revitalization, thermal control, and food production. An analog environment for long-duration human space travel, the conditions of isolation and confinement also enabled studies of human factors, medical sciences (both physiology and psychology) and crew training. Four tests were conducted, Phases I, II, IIa and III, with durations of 15, 30,60 and 91 days, respectively. The first phase focused on biological air regeneration, using wheat to generate enough oxygen for one experimental subject. The systems demonstrated in the later phases were increasingly complex and interdependent, and provided life support for four crew members. The tests were conducted using two human-rated, atmospherically-closed test chambers, the Variable Pressure Growth Chamber (VPGC) and the Integrated Life Support Systems Test Facility (ILSSTF). Systems included test articles (the life support hardware under evaluation), human accommodations (living quarters, kitchen, exercise equipment, etc.) and facility systems (emergency matrix system, power, cooling, etc.). The test team was managed by a lead engineer and a test director, and included test article engineers responsible for specific systems, subsystems or test articles, test conductors, facility engineers, chamber operators and engineering technicians, medical and safety officers, and science experimenters. A crew selection committee, comprised of psychologists, engineers and managers involved in the test, evaluated male and female volunteers who applied to be test subjects. Selection was based on the skills mix anticipated for each particular test, and utilized information from psychological and medical testing, data on the knowledge, experience and skills of the applicants, and team building exercises. The design, development, buildup and operation of test hardware and documentation followed the established NASA processes and requirements for test buildup and operation.
Conducting Closed Habitation Experiments: Experience from the Lunar Mars Life Support Test Project
NASA Technical Reports Server (NTRS)
Barta, Daniel J.; Edeen, Marybeth A.; Henninger, Donald L.
2006-01-01
The Lunar-Mars Life Support Test Project (LMLSTP) was conducted from 1995 through 1997 at the National Aeronautics and Space Administration s (NASA) Johnson Space Center (JSC) to demonstrate increasingly longer duration operation of integrated, closed-loop life support systems that employed biological and physicochemical techniques for water recycling, waste processing, air revitalization, thermal control, and food production. An analog environment for long-duration human space travel, the conditions of isolation and confinement also enabled studies of human factors, medical sciences (both physiology and psychology) and crew training. Four tests were conducted, Phases I, II, IIa and III, with durations of 15, 30, 60 and 91 days, respectively. The first phase focused on biological air regeneration, using wheat to generate enough oxygen for one experimental subject. The systems demonstrated in the later phases were increasingly complex and interdependent, and provided life support for four crew members. The tests were conducted using two human-rated, atmospherically-closed test chambers, the Variable Pressure Growth Chamber (VPGC) and the Integrated Life Support Systems Test Facility (ILSSTF). Systems included test articles (the life support hardware under evaluation), human accommodations (living quarters, kitchen, exercise equipment, etc.) and facility systems (emergency matrix system, power, cooling, etc.). The test team was managed by a lead engineer and a test director, and included test article engineers responsible for specific systems, subsystems or test articles, test conductors, facility engineers, chamber operators and engineering technicians, medical and safety officers, and science experimenters. A crew selection committee, comprised of psychologists, engineers and managers involved in the test, evaluated male and female volunteers who applied to be test subjects. Selection was based on the skills mix anticipated for each particular test, and utilized information from psychological and medical testing, data on the knowledge, experience and skills of the applicants, and team building exercises. The design, development, buildup and operation of test hardware and documentation followed the established NASA processes and requirements for test buildup and operation.
University of Washington Clinical Neutron Facility: Report on 26 Years of Operation
NASA Astrophysics Data System (ADS)
Laramore, George E.; Emery, Robert; Reid, David; Banerian, Stefani; Kalet, Ira; Jacky, Jonathan; Risler, Ruedi
2011-12-01
Particle radiotherapy facilities are highly capital intensive and must operate over decades to recoup the original investment. We describe the successful, long-term operation of a neutron radiotherapy center at the University of Washington, which has been operating continuously since September 1984. To date, 2836 patients have received neutron radiotherapy. The mission of the facility has also evolved to include the production of unique radioisotopes that cannot be made with the low-energy cyclotrons more commonly found in nuclear medicine departments. The facility is also used for neutron damage testing for industrial devices. In this paper, we describe the challenges of operating such a facility over an extended time period, including a planned maintenance and upgrade program serving diverse user groups, and summarize the major clinical results in terms of tumor control and normal tissue toxicity. Over time, the mix of patients being treated has shifted from common tumors such as prostate cancer, lung cancer, and squamous cell tumors of the head and neck to the rarer tumors such as salivary gland tumors and sarcomas due to the results of clinical trials. Current indications for neutron radiotherapy are described and neutron tolerance doses for a range of normal tissues presented.
Reaction-in-flight neutrons as a signature for shell mixing in National Ignition Facility capsules
NASA Astrophysics Data System (ADS)
Hayes, A. C.; Bradley, P. A.; Grim, G. P.; Jungman, Gerard; Wilhelmy, J. B.
2010-01-01
Analytic calculations and results from computational simulations are presented that suggest that reaction-in-flight (RIF) neutrons can be used to diagnose mixing of the ablator shell material into the fuel in deuterium-tritium (DT) capsules designed for the National Ignition Facility (NIF) [J. A. Paisner, J. D. Boyes, S. A. Kumpan, W. H. Lowdermilk, and M. S. Sorem, Laser Focus World 30, 75 (1994)]. Such mixing processes in NIF capsules are of fundamental physical interest and can have important effects on capsule performance, quenching the total thermonuclear yield. The sensitivity of RIF neutrons to hydrodynamical mixing arises through the dependence of RIF production on charged-particle stopping lengths in the mixture of DT fuel and ablator material. Since the stopping power in the plasma is a sensitive function of the electron temperature and density, it is also sensitive to mix. RIF production scales approximately inversely with the degree of mixing taking place, and the ratio of RIF to down-scattered neutrons provides a measure of the mix fraction and/or the mixing length. For sufficiently high-yield capsules, where spatially resolved RIF images may be possible, neutron imaging could be used to map RIF images into detailed mix images.
Smalyuk, V A; Tipton, R E; Pino, J E; Casey, D T; Grim, G P; Remington, B A; Rowley, D P; Weber, S V; Barrios, M; Benedetti, L R; Bleuel, D L; Bradley, D K; Caggiano, J A; Callahan, D A; Cerjan, C J; Clark, D S; Edgell, D H; Edwards, M J; Frenje, J A; Gatu-Johnson, M; Glebov, V Y; Glenn, S; Haan, S W; Hamza, A; Hatarik, R; Hsing, W W; Izumi, N; Khan, S; Kilkenny, J D; Kline, J; Knauer, J; Landen, O L; Ma, T; McNaney, J M; Mintz, M; Moore, A; Nikroo, A; Pak, A; Parham, T; Petrasso, R; Sayre, D B; Schneider, M B; Tommasini, R; Town, R P; Widmann, K; Wilson, D C; Yeamans, C B
2014-01-17
We present the first results from an experimental campaign to measure the atomic ablator-gas mix in the deceleration phase of gas-filled capsule implosions on the National Ignition Facility. Plastic capsules containing CD layers were filled with tritium gas; as the reactants are initially separated, DT fusion yield provides a direct measure of the atomic mix of ablator into the hot spot gas. Capsules were imploded with x rays generated in hohlraums with peak radiation temperatures of ∼294 eV. While the TT fusion reaction probes conditions in the central part (core) of the implosion hot spot, the DT reaction probes a mixed region on the outer part of the hot spot near the ablator-hot-spot interface. Experimental data were used to develop and validate the atomic-mix model used in two-dimensional simulations.
Does High School Facility Quality Affect Student Achievement? A Two-Level Hierarchical Linear Model
ERIC Educational Resources Information Center
Bowers, Alex J.; Urick, Angela
2011-01-01
The purpose of this study is to isolate the independent effects of high school facility quality on student achievement using a large, nationally representative U.S. database of student achievement and school facility quality. Prior research on linking school facility quality to student achievement has been mixed. Studies that relate overall…
A Componential Approach to Training Reading Skills.
1983-03-17
1 syllable, mixed vowels A2 16 one-syll., 4 two-syll., mixed vowels A3 14 one-syll., 6 two-syll., mixed vowels A4 All two-syllable, mixed vowels* B1 ...06520 I ERIC Facility-Acquisitions I Dr. John S. Brown 4833 Rugby Avenue XEROX Palo Alto Research Center Bethesda, MD 20014 3333 Coyote Road Palo Alto, CA
Public-private mix for TB and TB-HIV care in Lagos, Nigeria.
Daniel, O J; Adedeji Adejumo, O; Abdur-Razzaq, H A; Ngozi Adejumo, E; Salako, A A
2013-09-01
Private and public tuberculosis (TB) treatment centres in Lagos State, Nigeria. To assess the contribution of private health care providers to TB and TB-HIV (human immunodeficiency virus) case finding in Lagos State. A retrospective review of programme data submitted to the Lagos State TB and Leprosy Control Programme in 2011 by public, private for-profit (PFP) and private not-for-profit (PNFP) health care providers. A total of 8425 TB cases were notified by 31 private (11 PFP and 20 PNFP) and 99 public health facilities in Lagos State. Overall, the private facilities were responsible for 10.3% (866/8425) of the total TB cases notified. The proportion of TB patients tested for HIV was respectively 86.2%, 53.1% and 96.5% among public, PFP and PNFP facilities. Overall, 22.4% of the TB patients were HIV-positive. The HIV positivity rate among public, PFP and PNFP facilities was respectively 23.8%, 7.8% and 9.9%. Uptake of cotrimoxazole preventive therapy was respectively 69.6%, 25% and 38.2% among public, PFP and PNFP facilities, while that of antiretroviral therapy was respectively 23.8%, 8.3% and 9.1% in public, PFP and PNFP facilities. There is a need to scale up collaboration with the private sector, and particularly PNFP health providers.
Subsonic Jet Noise Reduced With Improved Internal Exhaust Gas Mixers
NASA Technical Reports Server (NTRS)
1996-01-01
Aircraft noise pollution is becoming a major environmental concern for the world community. The Federal Aviation Administration (FAA) is responding to this concern by imposing more stringent noise restrictions for aircraft certification then ever before to keep the U.S. industry competitive with the rest of the world. At the NASA Lewis Research Center, attempts are underway to develop noise-reduction technology for newer engines and for retrofitting existing engines so that they are as quiet as (or quieter than) required. Lewis conducted acoustic and Laser Doppler Velocimetry (LDV) tests using Pratt & Whitney's Internal Exhaust Gas Mixers (IEGM). The IEGM's mix the core flow with the fan flow prior to their common exhaust. All tests were conducted in Lewis' Aero-Acoustic Propulsion Laboratory--a semihemispheric dome open to the ambient atmosphere. This was the first time Laser Doppler Velocimetry was used in such a facility at Lewis. Jet exhaust velocity and turbulence and the internal velocity fields were detailed. Far-field acoustics were also measured. Pratt & Whitney provided 1/7th scale model test hardware (a 12-lobe mixer, a 20-lobe mixer, and a splitter) for 1.7 bypass ratio engines, and NASA provided the research engineers, test facility, and test time. The Pratt & Whitney JT8D-200 engine power conditions were used for all tests.
TANK 18-F AND 19-F TANK FILL GROUT SCALE UP TEST SUMMARY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stefanko, D.; Langton, C.
2012-01-03
High-level waste (HLW) tanks 18-F and 19-F have been isolated from FTF facilities. To complete operational closure the tanks will be filled with grout for the purpose of: (1) physically stabilizing the tanks, (2) limiting/eliminating vertical pathways to residual waste, (3) entombing waste removal equipment, (4) discouraging future intrusion, and (5) providing an alkaline, chemical reducing environment within the closure boundary to control speciation and solubility of select radionuclides. This report documents the results of a four cubic yard bulk fill scale up test on the grout formulation recommended for filling Tanks 18-F and 19-F. Details of the scale upmore » test are provided in a Test Plan. The work was authorized under a Technical Task Request (TTR), HLE-TTR-2011-008, and was performed according to Task Technical and Quality Assurance Plan (TTQAP), SRNL-RP-2011-00587. The bulk fill scale up test described in this report was intended to demonstrate proportioning, mixing, and transportation, of material produced in a full scale ready mix concrete batch plant. In addition, the material produced for the scale up test was characterized with respect to fresh properties, thermal properties, and compressive strength as a function of curing time.« less
Design and calibration of the mixing layer and wind tunnel
NASA Technical Reports Server (NTRS)
Bell, James H.; Mehta, Rabindra D.
1989-01-01
A detailed account of the design, assembly and calibration of a wind tunnel specifically designed for free-shear layer research is contained. The construction of this new facility was motivated by a strong interest in the study of plane mixing layers with varying initial and operating conditions. The Mixing Layer Wind tunnel is located in the Fluid Mechanics Laboratory at NASA Ames Research Center. The tunnel consists of two separate legs which are driven independently by centrifugal blowers connected to variable speed motors. The blower/motor combinations are sized such that one is smaller than the other, giving maximum flow speeds of about 20 and 40 m/s, respectively. The blower speeds can either be set manually or via the Microvax II computer. The two streams are allowed to merge in the test section at the sharp trailing edge of a slowly tapering splitter plate. The test section is 36 cm in the cross-stream direction, 91 cm in the spanwise direction and 366 cm in length. One test section side-wall is slotted for probe access and adjustable so that the streamwise pressure gradient may be controlled. The wind tunnel is also equipped with a computer controlled, three-dimensional traversing system which is used to investigate the flow fields with pressure and hot-wire instrumentation. The wind tunnel calibration results show that the mean flow in the test section is uniform to within plus or minus 0.25 pct and the flow angularity is less than 0.25 deg. The total streamwise free-stream turbulence intensity level is approximately 0.15 pct. Currently the wind tunnel is being used in experiments designed to study the three-dimensional structure of plane mixing layers and wakes.
The use of music in aged care facilities: A mixed-methods study.
Garrido, Sandra; Dunne, Laura; Perz, Janette; Chang, Esther; Stevens, Catherine J
2018-02-01
Music is frequently used in aged care, being easily accessible and cost-effective. Research indicates that certain types of musical engagement hold greater benefits than others. However, it is not clear how effectively music is utilized in aged care facilities and what the barriers are to its further use. This study used a mixed-methods paradigm, surveying 46 aged care workers and conducting in-depth interviews with 5, to explore how music is used in aged care facilities in Australia, staff perceptions of the impact of music on residents, and the barriers to more effective implementation of music in aged care settings.
Recent Advances in the LEWICE Icing Model
NASA Technical Reports Server (NTRS)
Wright, William B.; Addy, Gene; Struk, Peter; Bartkus, Tadas
2015-01-01
This paper will describe two recent modifications to the Glenn ICE software. First, a capability for modeling ice crystals and mixed phase icing has been modified based on recent experimental data. Modifications have been made to the ice particle bouncing and erosion model. This capability has been added as part of a larger effort to model ice crystal ingestion in aircraft engines. Comparisons have been made to ice crystal ice accretions performed in the NRC Research Altitude Test Facility (RATFac). Second, modifications were made to the run back model based on data and observations from thermal scaling tests performed in the NRC Altitude Icing Tunnel.
Teno, Joan M; Feng, Zhanlian; Mitchell, Susan L; Kuo, Sylvia; Intrator, Orna; Mor, Vincent
2008-05-01
To determine whether adoption of Medicaid case mix reimbursement is associated with greater prevalence of feeding tube use in nursing home (NH) residents. Secondary analysis of longitudinal administrative data about the prevalence of feeding tube insertion and surveys of states' adoption of case mix reimbursement. NHs in the United States. NH residents at the time of NH inspection between 1993 and 2004. Facility prevalence of feeding tubes reported at the state inspection of NHs reported in the Online Survey, Certification and Reporting database and interviews with state policy makers regarding the adoption of case mix reimbursement. Between 1993 and 2004, 16 states adopted Resource Utilization Group case mix reimbursement. States varied in the prevalence of feeding tubes in their NHs. Although the use of feeding tube increased substantially over the years of the study, once temporal trends and facility fixed effects were accounted for, case mix reimbursement was not associated with greater prevalence of feeding tube use. The adoption of Medicaid case mix reimbursement was not associated with an increase in the prevalence of feeding tube use.
NASA Technical Reports Server (NTRS)
1998-01-01
NASA engineers successfully tested a Russian-built rocket engine on November 4, 1998 at the Marshall Space Flight Center (MSFC) Advanced Engine Test Facility, which had been used for testing the Saturn V F-1 engines and Space Shuttle Main engines. The MSFC was under a Space Act Agreement with Lockheed Martin Astronautics of Denver to provide a series of test firings of the Atlas III propulsion system configured with the Russian-designed RD-180 engine. The tests were designed to measure the performance of the Atlas III propulsion system, which included avionics and propellant tanks and lines, and how these components interacted with the RD-180 engine. The RD-180 is powered by kerosene and liquid oxygen, the same fuel mix used in Saturn rockets. The RD-180, the most powerful rocket engine tested at the MSFC since Saturn rocket tests in the 1960s, generated 860,000 pounds of thrust.
NASA Technical Reports Server (NTRS)
Drozda, Tomasz G.; Cabell, Karen F.; Ziltz, Austin R.; Hass, Neal E.; Inman, Jennifer A.; Burns, Ross A.; Bathel, Brett F.; Danehy, Paul M.
2017-01-01
The current work compares experimentally and computationally obtained nitric oxide (NO) planar laser induced fluorescence (PLIF) images of the mixing flowfields for three types of high-speed fuel injectors: a strut, a ramp, and a rectangular flushwall. These injection devices, which exhibited promising mixing performance at lower flight Mach numbers, are currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. The EIMP aims to investigate scramjet fuel injection and mixing physics, and improve the understanding of underlying physical processes relevant to flight Mach numbers greater than eight. In the experiments, conducted in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF), the injectors are placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number air flow at the entrance of a scramjet combustor. Helium is used as an inert substitute for hydrogen fuel. Both schlieren and PLIF techniques are applied to obtain mixing flowfield flow visualizations. The experimental PLIF is obtained by using a UV laser sheet to interrogate a plane of the flow by exciting fluorescence from the NO molecules, which are present in the AHSTF air. Consequently, the absence of signal in the resulting PLIF images is an indication of pure helium (fuel). The computational PLIF is obtained by applying a fluorescence model for NO to the results of the Reynolds-averaged simulations (RAS) of the mixing flow field carried out using the VULCAN-CFD solver. This approach is required because the PLIF signal is a nonlinear function of not only NO concentration, but also pressure, temperature, and the flow velocity. This complexity allows additional flow features to be identified and compared with those obtained from the computational fluid dynamics (CFD) simulations, however, such comparisons are only semiquantitative. Three-dimensional image reconstruction, similar to that used in magnetic resonance imaging, is also used to obtain images in the streamwise and spanwise planes from select cross-stream PLIF plane data. Synthetic schlieren is also computed from the RAS data. Good agreement between the experimental and computational results provides increased confidence in the CFD simulations for investigations of injector performance.
Improving Mechanical Properties of Hot Mix Asphalt Using Fibres and Polymers in Developing Countries
NASA Astrophysics Data System (ADS)
Preciado, Jaime; Martínez Arguelles, Gilberto; Dugarte, Margareth; Bonicelli, Alessandra; Cantero, Julio; Vega, Daniela; Barros, Yennis
2017-10-01
The enhancement of mechanical properties and long term performance of hot mix asphalt (HMA) should be considered as a goal in order to achieve a transport infrastructure really sustainable. However, this issue becomes a difficult task, if conventional HMA are used. In fact, performance of conventional HMA, usually presents poor long term performance and functional distresses related to high and low temperatures, which in turn implies higher maintenance costs and superior carbon footprints. To overcome this weaken, bitumen industry has been developing new polymer modifiers, additives to improve HMA behaviour. One of the techniques most used in developed countries to enhance HMA behaviour is the use of modified bitumen. Modifying the bitumen, and then producing modified HMA requires specific equipment and facilities that may be time-consuming, expensive and hard to manage. For instance, to warranty a successful modifying process, storage and handling of the modified bitumen are issues very complex to handle. On the other hand, producing a polymer modified HMA by adding polymers and additives directly during the bitumen/aggregate mixing process may offer very interesting advantages since the economical, production and sustainability standpoint. This paper aimed to determine the feasibility of the incorporation of fibres and plastomeric polymers into different types of HMA by means of the “dry process” (to add polymers during the mixing of aggregate and bitumen in the HMA plant) to produce polymer modified mixes. Thus, laboratory tests including Marshall Stability, Indirect Tensile Stiffness Modulus, repeated load test and Indirect Tensile Strength test were performed to assess the effect of the inclusion of fibres and plastomeric polymers on mechanical and volumetric properties of selected mixes. Results showed that the modification of bituminous mixtures following the “dry process” could be used to improve the performance and long term properties of HMA.
Ice Growth Measurements from Image Data to Support Ice Crystal and Mixed-Phase Accretion Testing
NASA Technical Reports Server (NTRS)
Struk, Peter M.; Lynch, Christopher J.
2012-01-01
This paper describes the imaging techniques as well as the analysis methods used to measure the ice thickness and growth rate in support of ice-crystal icing tests performed at the National Research Council of Canada (NRC) Research Altitude Test Facility (RATFac). A detailed description of the camera setup, which involves both still and video cameras, as well as the analysis methods using the NASA Spotlight software, are presented. Two cases, one from two different test entries, showing significant ice growth are analyzed in detail describing the ice thickness and growth rate which is generally linear. Estimates of the bias uncertainty are presented for all measurements. Finally some of the challenges related to the imaging and analysis methods are discussed as well as methods used to overcome them.
Ice Growth Measurements from Image Data to Support Ice-Crystal and Mixed-Phase Accretion Testing
NASA Technical Reports Server (NTRS)
Struk, Peter, M; Lynch, Christopher, J.
2012-01-01
This paper describes the imaging techniques as well as the analysis methods used to measure the ice thickness and growth rate in support of ice-crystal icing tests performed at the National Research Council of Canada (NRC) Research Altitude Test Facility (RATFac). A detailed description of the camera setup, which involves both still and video cameras, as well as the analysis methods using the NASA Spotlight software, are presented. Two cases, one from two different test entries, showing significant ice growth are analyzed in detail describing the ice thickness and growth rate which is generally linear. Estimates of the bias uncertainty are presented for all measurements. Finally some of the challenges related to the imaging and analysis methods are discussed as well as methods used to overcome them.
NASA Technical Reports Server (NTRS)
Janardan, B. A.; Hoff, G. E.; Barter, J. W.; Martens, S.; Gliebe, P. R.; Mengle, V.; Dalton, W. N.; Saiyed, Naseem (Technical Monitor)
2000-01-01
This report describes the work performed by General Electric Aircraft Engines (GEAE) and Allison Engine Company (AEC) on NASA Contract NAS3-27720 AoI 14.3. The objective of this contract was to generate quality jet noise acoustic data for separate-flow nozzle models and to design and verify new jet-noise-reduction concepts over a range of simulated engine cycles and flight conditions. Five baseline axisymmetric separate-flow nozzle models having bypass ratios of five and eight with internal and external plugs and 11 different mixing-enhancer model nozzles (including chevrons, vortex-generator doublets, and a tongue mixer) were designed and tested in model scale. Using available core and fan nozzle hardware in various combinations, 28 GEAE/AEC separate-flow nozzle/mixing-enhancer configurations were acoustically evaluated in the NASA Glenn Research Center Aeroacoustic and Propulsion Laboratory. This report describes model nozzle features, facility and data acquisition/reduction procedures, the test matrix, and measured acoustic data analyses. A number of tested core and fan mixing enhancer devices and combinations of devices gave significant jet noise reduction relative to separate-flow baseline nozzles. Inward-flip and alternating-flip core chevrons combined with a straight-chevron fan nozzle exceeded the NASA stretch goal of 3 EPNdB jet noise reduction at typical sideline certification conditions.
EFFECTS OF MIXING AND AGING ON WATER QUALITY IN DISTRIBUTION SYSTEM STORAGE FACILITIES
Aging of water in distribution system storage facilities can lead to deterioration of the water quality due to loss of disinfectant residual and bacterial regrowth. Facilities should be operated to insure that the age of the water is not excessive taking into account the quality...
Laboratory simulations of the atmospheric mixed-layer in flow over complex topography
A laboratory study of the influence of complex terrain on the interface between a well-mixed boundary layer and an elevated stratified layer was conducted in the towing-tank facility of the U.S. Environmental Protection Agency. The height of the mixed layer in the daytime boundar...
Background information for Van Aken on testing of NESTT product
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reynolds, John G.
2016-11-18
Debris from explosives testing in a shot tank that contains 4 weight percent or less of explosive is shown to be non-reactive under the specified testing protocol in the Code of Federal Regulations. This debris can then be regarded as a non-hazardous waste on the basis of reactivity, when collected and packaged in a specified manner. If it is contaminated with radioactive components (e.g. depleted uranium), it can therefore be disposed of as radioactive waste or mixed waste, as appropriate (note that debris may contain other materials that render it hazardous, such as beryllium). We also discuss potential waste generationmore » issues in contained firing operations that are applicable to the planned new Contained Firing Facility (CFF).« less
NASA Technical Reports Server (NTRS)
Johnsen, R. L.; Cullom, R. R.
1977-01-01
A performance test of several experimental afterburner configurations was conducted with a mixed-flow turbofan engine in an altitude facility. The simulated flight conditions were for Mach 1.4 at two altitudes, 12,190 and 14,630 meters. Turbine discharge temperatures of 889 and 1056 K were used. A production afterburner was tested for comparison. The research afterburners included partial forced mixers with V-gutter flameholders, a carburetted V-gutter flameholder, and a triple ring V-gutter flameholder with four swirl-can fuel mixers. Fuel injection variations were included. Performance data shown include augmented thrust ratio, thrust specific fuel consumption, combustion efficiency, and total pressure drop across the afterburner.
1998-11-04
NASA engineers successfully tested a Russian-built rocket engine on November 4, 1998 at the Marshall Space Flight Center (MSFC) Advanced Engine Test Facility, which had been used for testing the Saturn V F-1 engines and Space Shuttle Main engines. The MSFC was under a Space Act Agreement with Lockheed Martin Astronautics of Denver to provide a series of test firings of the Atlas III propulsion system configured with the Russian-designed RD-180 engine. The tests were designed to measure the performance of the Atlas III propulsion system, which included avionics and propellant tanks and lines, and how these components interacted with the RD-180 engine. The RD-180 is powered by kerosene and liquid oxygen, the same fuel mix used in Saturn rockets. The RD-180, the most powerful rocket engine tested at the MSFC since Saturn rocket tests in the 1960s, generated 860,000 pounds of thrust.
Real estate planning for population health.
McHugh, Margie
2014-11-01
Factors that health systems should consider when performing strategic assessments of their portfolios of ambulatory facilities include: Inventory. Location Facility condition. Service mix. Space use and capacity. Occupancy metrics. Strategic and economic opportunities.
A Remote Absorption Process for Disposal of Evaporate and Reverse Osmosis Concentrates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brunsell, D.A.
2008-07-01
Many commercial nuclear plants and DOE facilities generate secondary waste streams consisting of evaporator bottoms and reverse osmosis (RO) concentrate. Since liquids are not permitted in disposal facilities, these waste streams must be converted to dry solids, either by evaporation to dried solids or by solidification to liquid-free solids. Evaporation of the liquid wastes reduces their volume, but requires costly energy and capital equipment. In some cases, concentration of the contaminants during drying can cause the waste to exceed Class A waste for nuclear utilities or exceed DOE transuranic limits. This means that disposal costs will be increased, or that,more » when the Barnwell, SC disposal site closes to waste outside of the Atlantic Compact in July 2008, the waste will be precluded from disposal for the foreseeable future). Solidification with cement agents requires less energy and equipment than drying, but results in a volume increase of 50-100%. The doubling or tripling of waste weight, along with the increased volume, sharply increases shipping and disposal costs. Confronted with these unattractive alternatives, Diversified Technologies Services (DTS), in conjunction with selected nuclear utilities and D and D operations at Rocky Flats, undertook an exploratory effort to convert this liquid wastewater to a solid without using cement. This would avoid the bulking effect of cement, and permit the waste to be disposed of the Energy Solutions facility in Utah as well as some DOE facilities. To address the need for an attractive alternative to drying and cement solidification, a test program was developed using a polymer absorbent media to convert the concentrate streams to a liquid-free waste form that meets the waste acceptance criteria of the pertinent burial sites. Two approaches for mixing the polymer with the liquid were tested: mechanical mixing and in-situ incorporation. As part of this test program, a process control program (PCP) was developed that is 100% scalable from a concentrate test sample as small as 50 grams to full-scale processing of 100 cubic foot containers or larger. In summary: The absorption process offers utilities a viable and less costly alternative to on-site drying or solidification of concentrates. The absorption process can be completed by site personnel or by a vendor as a turnkey service. The process is suitable for multiple types of waste, including RO and evaporator concentrates, sludges, and other difficult to process waters and wet solids. (author)« less
Reaction-in-flight neutrons as a signature for shell mixing in National Ignition Facility capsules
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hayes, A. C.; Bradley, P. A.; Grim, G. P.
2010-01-15
Analytic calculations and results from computational simulations are presented that suggest that reaction-in-flight (RIF) neutrons can be used to diagnose mixing of the ablator shell material into the fuel in deuterium-tritium (DT) capsules designed for the National Ignition Facility (NIF) [J. A. Paisner, J. D. Boyes, S. A. Kumpan, W. H. Lowdermilk, and M. S. Sorem, Laser Focus World 30, 75 (1994)]. Such mixing processes in NIF capsules are of fundamental physical interest and can have important effects on capsule performance, quenching the total thermonuclear yield. The sensitivity of RIF neutrons to hydrodynamical mixing arises through the dependence of RIFmore » production on charged-particle stopping lengths in the mixture of DT fuel and ablator material. Since the stopping power in the plasma is a sensitive function of the electron temperature and density, it is also sensitive to mix. RIF production scales approximately inversely with the degree of mixing taking place, and the ratio of RIF to down-scattered neutrons provides a measure of the mix fraction and/or the mixing length. For sufficiently high-yield capsules, where spatially resolved RIF images may be possible, neutron imaging could be used to map RIF images into detailed mix images.« less
Strategy of Construction and Demolition Waste Management after Chemical Industry Facilities Removal
NASA Astrophysics Data System (ADS)
Tashkinova, I. N.; Batrakova, G. M.; Vaisman, Ya I.
2017-06-01
Mixed waste products are generated in the process of irrelevant industrial projects’ removal if conventional techniques of their demolition and dismantling are applied. In Russia the number of unused chemical industry facilities including structures with high rate of wear is growing. In removing industrial buildings and production shops it is used conventional techniques of demolition and dismantling in the process of which mixed waste products are generated. The presence of hazardous chemicals in these wastes makes difficulties for their use and leads to the increasing volume of unutilized residues. In the process of chemical industry facilities’ removal this fact takes on special significance as a high level of hazardous chemicals in the waste composition demands for the realization of unprofitable measures aimed at ensuring environmental and industrial safety. The proposed strategy of managing waste originated from the demolition and dismantling of chemical industry facilities is based on the methodology of industrial metabolism which allows identifying separate material flows of recycled, harmful and ballast components, performing separate collection of components during removal and taking necessary preventive measures. This strategy has been tested on the aniline synthesis plant being in the process of removal. As a result, a flow of 10 wt. %, subjected to decontamination, was isolated from the total volume of construction and demolition waste (C&D waste). The considered approach allowed using the resource potential of more than 80wt. % of waste and minimizing the disposed waste volume.
The mixed low-level waste problem in BE/NWN capsule
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hensley, D.C.
1999-07-01
The Boh Environmental, LLC (BE) and Northwest Nuclear, LLC (NWN) program addresses the problem of diminishing capacity in the United States to store mixed waste. A lack of an alternative program has caused the US Department of Energy (DOE) to indefinitely store all of its mixed waste in Resource Conservation and Recovery Act (RCRA) compliant storage facilities. Unfortunately, this capacity is fast approaching the administrative control limit. The combination of unique BE encapsulation and NWN waste characterization technologies provides an effective solution to DOE's mixed-waste dilemma. The BE ARROW-PAK technique encapsulates mixed low-level waste (MLLW) in extra-high molecular weight, high-densitymore » polyethylene, pipe-grade resin cylinders. ARROW-PAK applications include waste treatment, disposal, transportation (per 49 CFR 173), vault encasement, and interim/long-term storage for 100 to 300 yr. One of the first demonstrations of this treatment/storage technique successfully treated 880 mixed-waste debris drums at the DOE Hanford Site in 1997. NWN, deploying the APNea neutron assay technology, provides the screening and characterization capability necessary to ensure that radioactive waste is correctly categorized as either transuranic (TRU) or LLW. MLLW resulting from D and D activities conducted at the Oak Ridge East Tennessee Technology Park will be placed into ARROW-PAK containers following comprehensive characterization of the waste by NWN. The characterized and encapsulated waste will then be shipped to a commercial disposal facility, where the shipments meet all waste acceptance criteria of the disposal facility including treatment criteria.« less
PROPERTIES IMPORTANT TO MIXING FOR WTP LARGE SCALE INTEGRATED TESTING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koopman, D.; Martino, C.; Poirier, M.
2012-04-26
Large Scale Integrated Testing (LSIT) is being planned by Bechtel National, Inc. to address uncertainties in the full scale mixing performance of the Hanford Waste Treatment and Immobilization Plant (WTP). Testing will use simulated waste rather than actual Hanford waste. Therefore, the use of suitable simulants is critical to achieving the goals of the test program. External review boards have raised questions regarding the overall representativeness of simulants used in previous mixing tests. Accordingly, WTP requested the Savannah River National Laboratory (SRNL) to assist with development of simulants for use in LSIT. Among the first tasks assigned to SRNL wasmore » to develop a list of waste properties that matter to pulse-jet mixer (PJM) mixing of WTP tanks. This report satisfies Commitment 5.2.3.1 of the Department of Energy Implementation Plan for Defense Nuclear Facilities Safety Board Recommendation 2010-2: physical properties important to mixing and scaling. In support of waste simulant development, the following two objectives are the focus of this report: (1) Assess physical and chemical properties important to the testing and development of mixing scaling relationships; (2) Identify the governing properties and associated ranges for LSIT to achieve the Newtonian and non-Newtonian test objectives. This includes the properties to support testing of sampling and heel management systems. The test objectives for LSIT relate to transfer and pump out of solid particles, prototypic integrated operations, sparger operation, PJM controllability, vessel level/density measurement accuracy, sampling, heel management, PJM restart, design and safety margin, Computational Fluid Dynamics (CFD) Verification and Validation (V and V) and comparison, performance testing and scaling, and high temperature operation. The slurry properties that are most important to Performance Testing and Scaling depend on the test objective and rheological classification of the slurry (i.e., Newtonian or non-Newtonian). The most important properties for testing with Newtonian slurries are the Archimedes number distribution and the particle concentration. For some test objectives, the shear strength is important. In the testing to collect data for CFD V and V and CFD comparison, the liquid density and liquid viscosity are important. In the high temperature testing, the liquid density and liquid viscosity are important. The Archimedes number distribution combines effects of particle size distribution, solid-liquid density difference, and kinematic viscosity. The most important properties for testing with non-Newtonian slurries are the slurry yield stress, the slurry consistency, and the shear strength. The solid-liquid density difference and the particle size are also important. It is also important to match multiple properties within the same simulant to achieve behavior representative of the waste. Other properties such as particle shape, concentration, surface charge, and size distribution breadth, as well as slurry cohesiveness and adhesiveness, liquid pH and ionic strength also influence the simulant properties either directly or through other physical properties such as yield stress.« less
NASA Technical Reports Server (NTRS)
Drozda, Tomasz, G.; Cabell, Karen F.; Ziltz, Austin R.; Hass, Neil E.; Inman, Jennifer A.; Burns, Ross A.; Bathel, Brett F.; Danehy, Paul M.; Abul-Huda, Yasin M.; Gamba, Mirko
2017-01-01
The current work compares experimentally and computationally obtained nitric oxide (NO) planar laser-induced fluorescence (PLIF) images of the mixing flowfields for three types of high-speed fuel injectors: a strut, a ramp, and a rectangular flush-wall. These injection devices, which exhibited promising mixing performance at lower flight Mach numbers, are currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. The EIMP aims to investigate scramjet fuel injection and mixing physics, and improve the understanding of underlying physical processes relevant to flight Mach numbers greater than eight. In the experiments, conducted in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF), the injectors are placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number air flow at the entrance of a scramjet combustor. Helium is used as an inert substitute for hydrogen fuel. The PLIF is obtained by using a tunable laser to excite the NO, which is present in the AHSTF air as a direct result of arc-heating. Consequently, the absence of signal is an indication of pure helium (fuel). The PLIF images computed from the computational fluid dynamics (CFD) simulations are obtained by combining a fluorescence model for NO with the Reynolds-Averaged Simulation results carried out using the VULCAN-CFD solver to obtain a computational equivalent of the experimentally measured PLIF signal. The measured NO PLIF signal is mainly a function of NO concentration allowing for semi-quantitative comparisons between the CFD and the experiments. The PLIF signal intensity is also sensitive to pressure and temperature variations in the flow, allowing additional flow features to be identified and compared with the CFD. Good agreement between the PLIF and the CFD results provides increased confidence in the CFD simulations for investigations of injector performance.
NASA Astrophysics Data System (ADS)
Khot, P. M.; Nehete, Y. G.; Fulzele, A. K.; Baghra, Chetan; Mishra, A. K.; Afzal, Mohd.; Panakkal, J. P.; Kamath, H. S.
2012-01-01
Impregnated Agglomerate Pelletization (IAP) technique has been developed at Advanced Fuel Fabrication Facility (AFFF), BARC, Tarapur, for manufacturing (Th, 233U)O 2 mixed oxide fuel pellets, which are remotely fabricated in hot cell or shielded glove box facilities to reduce man-rem problem associated with 232U daughter radionuclides. This technique is being investigated to fabricate the fuel for Indian Advanced Heavy Water Reactor (AHWR). In the IAP process, ThO 2 is converted to free flowing spheroids by powder extrusion route in an unshielded facility which are then coated with uranyl nitrate solution in a shielded facility. The dried coated agglomerate is finally compacted and then sintered in oxidizing/reducing atmosphere to obtain high density (Th,U)O 2 pellets. In this study, fabrication of (Th,U)O 2 mixed oxide pellets containing 3-5 wt.% UO 2 was carried out by IAP process. The pellets obtained were characterized using optical microscopy, XRD and alpha autoradiography. The results obtained were compared with the results for the pellets fabricated by other routes such as Coated Agglomerate Pelletization (CAP) and Powder Oxide Pelletization (POP) route.
Nurse staffing levels and Medicaid reimbursement rates in nursing facilities.
Harrington, Charlene; Swan, James H; Carrillo, Helen
2007-06-01
To examine the relationship between nursing staffing levels in U.S. nursing homes and state Medicaid reimbursement rates. Facility staffing, characteristics, and case-mix data were from the federal On-Line Survey Certification and Reporting (OSCAR) system and other data were from public sources. Ordinary least squares and two-stage least squares regression analyses were used to separately examine the relationship between registered nurse (RN) and total nursing hours in all U.S. nursing homes in 2002, with two endogenous variables: Medicaid reimbursement rates and resident case mix. RN hours and total nursing hours were endogenous with Medicaid reimbursement rates and resident case mix. As expected, Medicaid nursing home reimbursement rates were positively related to both RN and total nursing hours. Resident case mix was a positive predictor of RN hours and a negative predictor of total nursing hours. Higher state minimum RN staffing standards was a positive predictor of RN and total nursing hours while for-profit facilities and the percent of Medicaid residents were negative predictors. To increase staffing levels, average Medicaid reimbursement rates would need to be substantially increased while higher state minimum RN staffing standards is a stronger positive predictor of RN and total nursing hours.
Sport Facility Planning and Management. Sport Management Library.
ERIC Educational Resources Information Center
Farmer, Peter J.; Mulrooney, Aaron L.; Ammon, Rob, Jr.
Students of sports facilities management will need to acquire a wide variety of managerial skills and knowledge in order to be adequately prepared to plan and manage these facilities. This textbook offers students a mix of practical examples and recognized theory to help them in the planning, constructing, promoting, and managing of sports…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bostick, W.D.; Hoffmann, D.P.; Stevenson, R.J.
The category of sludges, filter cakes, and other waste processing residuals represent the largest volume of low-level mixed (hazardous and radioactive) wastes within the US Department of Energy (DOE) complex. Treatment of these wastes to minimize the mobility of contaminants, and to eliminate the presence of free water, is required under the Federal Facility Compliance Act agreements between DOE and the Environmental Protection Agency. In the text, we summarize the currently available data for several of the high priority mixed-waste sludge inventories within DOE. Los Alamos National Laboratory TA-50 Sludge and Rocky Flats Plant By-Pass Sludge are transuranic (TRU)-contaminated sludgesmore » that were isolated with the use of silica-based filter aids. The Oak Ridge Y-12 Plant West End Treatment Facility Sludge is predominantly calcium carbonate and biomass. The Oak Ridge K-25 Site Pond Waste is a large-volume waste stream, containing clay, silt, and other debris in addition to precipitated metal hydroxides. We formulate ``simulants`` for the waste streams described above, using cerium oxide as a surrogate for the uranium or plutonium present in the authentic material. Use of nonradiological surrogates greatly simplifies material handling requirements for initial treatability studies. The use of synthetic mixtures for initial treatability testing will facilitate compositional variation for use in conjunction with statistical design experiments; this approach may help to identify any ``operating window`` limitations. The initial treatability testing demonstrations utilizing these ``simulants`` will be based upon vitrification, although the materials are also amenable to testing grout-based and other stabilization procedures. After the feasibility of treatment and the initial evaluation of treatment performance has been demonstrated, performance must be verified using authentic samples of the candidate waste stream.« less
Looking Southeast from Second Floor Mezzanine of Pellet Plant to ...
Looking Southeast from Second Floor Mezzanine of Pellet Plant to Erbia Mixing Area and Poreformer and Acrawax Mixing Station - Hematite Fuel Fabrication Facility, Pellet Plant, 3300 State Road P, Festus, Jefferson County, MO
A random distribution reacting mixing layer model
NASA Technical Reports Server (NTRS)
Jones, Richard A.; Marek, C. John; Myrabo, Leik N.; Nagamatsu, Henry T.
1994-01-01
A methodology for simulation of molecular mixing, and the resulting velocity and temperature fields has been developed. The ideas are applied to the flow conditions present in the NASA Lewis Research Center Planar Reacting Shear Layer (PRSL) facility, and results compared to experimental data. A gaussian transverse turbulent velocity distribution is used in conjunction with a linearly increasing time scale to describe the mixing of different regions of the flow. Equilibrium reaction calculations are then performed on the mix to arrive at a new species composition and temperature. Velocities are determined through summation of momentum contributions. The analysis indicates a combustion efficiency of the order of 80 percent for the reacting mixing layer, and a turbulent Schmidt number of 2/3. The success of the model is attributed to the simulation of large-scale transport of fluid. The favorable comparison shows that a relatively quick and simple PC calculation is capable of simulating the basic flow structure in the reacting and nonreacting shear layer present in the facility given basic assumptions about turbulence properties.
NASA Astrophysics Data System (ADS)
Murphy, T. J.; Kyrala, G. A.; Krasheninnikova, N. S.; Bradley, P. A.; Cobble, J. A.; Tregillis, I. L.; Obrey, K. A. D.; Baumgaertel, J. A.; Hsu, S. C.; Shah, R. C.; Hakel, P.; Kline, J. L.; Schmitt, M. J.; Kanzleiter, R. J.; Batha, S. H.; Wallace, R. J.; Bhandarkar, S.; Fitzsimmons, P.; Hoppe, M.; Nikroo, A.; McKenty, P.
2016-03-01
Capsules driven with polar drive [1, 2] on the National Ignition Facility [3] are being used [4] to study mix in convergent geometry. In preparation for experiments that will utilize deuterated plastic shells with a pure tritium fill, hydrogen-filled capsules with copper- doped deuterated layers have been imploded on NIF to provide spectroscopic and nuclear measurements of capsule performance. Experiments have shown that the mix region, when composed of shell material doped with about 1% copper (by atom), reaches temperatures of about 2 keV, while undoped mixed regions reach about 3 keV. Based on the yield from these implosions, we estimate the thickness of CD that mixed into the gas as between about 0.25 and 0.43 μm of the inner capsule surface, corresponding to about 5 to 9 μg of material. Using 5 atm of tritium as the fill gas should result in over 1013 DT neutrons being produced, which is sufficient for neutron imaging [5].
Impact of chemistry on Standard High Solids Vessel Design mixing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poirier, M.
2016-03-02
The plan for resolving technical issues regarding mixing performance within vessels of the Hanford Waste Treatment Plant Pretreatment Facility directs a chemical impact study to be performed. The vessels involved are those that will process higher (e.g., 5 wt % or more) concentrations of solids. The mixing equipment design for these vessels includes both pulse jet mixers (PJM) and air spargers. This study assesses the impact of feed chemistry on the effectiveness of PJM mixing in the Standard High Solids Vessel Design (SHSVD). The overall purpose of this study is to complement the Properties that Matter document in helping tomore » establish an acceptable physical simulant for full-scale testing. The specific objectives for this study are (1) to identify the relevant properties and behavior of the in-process tank waste that control the performance of the system being tested, (2) to assess the solubility limits of key components that are likely to precipitate or crystallize due to PJM and sparger interaction with the waste feeds, (3) to evaluate the impact of waste chemistry on rheology and agglomeration, (4) to assess the impact of temperature on rheology and agglomeration, (5) to assess the impact of organic compounds on PJM mixing, and (6) to provide the technical basis for using a physical-rheological simulant rather than a physical-rheological-chemical simulant for full-scale vessel testing. Among the conclusions reached are the following: The primary impact of precipitation or crystallization of salts due to interactions between PJMs or spargers and waste feeds is to increase the insoluble solids concentration in the slurries, which will increase the slurry yield stress. Slurry yield stress is a function of pH, ionic strength, insoluble solids concentration, and particle size. Ionic strength and chemical composition can affect particle size. Changes in temperature can affect SHSVD mixing through its effect on properties such as viscosity, yield stress, solubility, and vapor pressure, or chemical reactions that occur at high temperatures. Organic compounds will affect SHSVD mixing through their effect on properties such as rheology, particle agglomeration/size, particle density, and particle concentration.« less
Camara, A; Bah-Sow, O Y; Baldé, N M; Camara, L M; Barry, I S; Bah, B; Diallo, M; Chaperon, J; Riou, F
2009-06-01
Complex care pathways can result in detrimental treatment delay particularly in tuberculosis patients. The purpose of this retrospective study was to assess the care pathways followed by tuberculosis patients prior to diagnosis and to assess impact on the delay for initiation of treatment in Conakry, Guinea. A total of 112 patients were interviewed at the time of first admission for pulmonary tuberculosis with positive bacilloscopy. Based on interview data, pathways were classified as conventional (use of health care facilities only) and mixed (use of health care facilities, self-medication, and traditional medicine). The correlation between patient characteristics and type of pathway was assessed by univariate and multivariate analysis and the two groups, i.e., conventional vs. mixed, were compared with regard to delay for initiation of treatment. The care pathway was classified as mixed in two out of three patients. Multivariate analysis showed that this type of pathway was only correlated with schooling (p=0.02). The mean delay for treatment was similar, i.e., 13.4 and 12.8 weeks for conventional and mixed pathways respectively (p<0.68). The percentage of pathways including three consultations at health care facilities was significantly higher in the conventional than mixed group (72% vs. 30%, p<0.001). The main reasons given for delayed use of health care facilities were poor knowledge of tuberculosis symptoms (26%) and high cost of care (12%). The findings of this study indicate that tuberculosis patients follow a variety of care pathways that can lead to delayed treatment. An information campaign is needed to increase awareness among the population and care providers.
Daly, Tamara; Banerjee, Albert; Armstrong, Pat; Armstrong, Hugh; Szebehely, Marta
2011-06-01
We conducted a mixed-methods study-- the focus of this article--to understand how workers in long-term care facilities experienced working conditions. We surveyed unionized care workers in Ontario (n = 917); we also surveyed workers in three Canadian provinces (n = 948) and four Scandinavian countries (n = 1,625). In post-survey focus groups, we presented respondents with survey questions and descriptive statistical findings, and asked them: "Does this reflect your experience?" Workers reported time pressures and the frequency of experiences of physical violence and unwanted sexual attention, as we explain. We discuss how iteratively mixing qualitative and quantitative methods to triangulate survey and focus group results led to expected data convergence and to unexpected data divergence that revealed a normalized culture of structural violence in long-term care facilities. We discuss how the finding of structural violence emerged and also the deeper meaning, context, and insights resulting from our combined methods.
MIP models for connected facility location: A theoretical and computational study☆
Gollowitzer, Stefan; Ljubić, Ivana
2011-01-01
This article comprises the first theoretical and computational study on mixed integer programming (MIP) models for the connected facility location problem (ConFL). ConFL combines facility location and Steiner trees: given a set of customers, a set of potential facility locations and some inter-connection nodes, ConFL searches for the minimum-cost way of assigning each customer to exactly one open facility, and connecting the open facilities via a Steiner tree. The costs needed for building the Steiner tree, facility opening costs and the assignment costs need to be minimized. We model ConFL using seven compact and three mixed integer programming formulations of exponential size. We also show how to transform ConFL into the Steiner arborescence problem. A full hierarchy between the models is provided. For two exponential size models we develop a branch-and-cut algorithm. An extensive computational study is based on two benchmark sets of randomly generated instances with up to 1300 nodes and 115,000 edges. We empirically compare the presented models with respect to the quality of obtained bounds and the corresponding running time. We report optimal values for all but 16 instances for which the obtained gaps are below 0.6%. PMID:25009366
Teno, Joan M.; Feng, Zhanlian; Mitchell, Susan L.; Kuo, Sylvia; Intrator, Orna; Mor, Vincent
2013-01-01
OBJECTIVES To determine whether adoption of Medicaid case mix reimbursement is associated with greater prevalence of feeding tube use in nursing home (NH) residents. DESIGN Secondary analysis of longitudinal administrative data about the prevalence of feeding tube insertion and surveys of states’ adoption of case mix reimbursement. SETTING NHs in the United States. PARTICIPANTS NH residents at the time of NH inspection between 1993 and 2004. MEASUREMENTS Facility prevalence of feeding tubes reported at the state inspection of NHs reported in the Online Survey, Certification and Reporting database and interviews with state policy makers regarding the adoption of case mix reimbursement. RESULTS Between 1993 and 2004, 16 states adopted Resource Utilization Group case mix reimbursement. States varied in the prevalence of feeding tubes in their NHs. Although the use of feeding tube increased substantially over the years of the study, once temporal trends and facility fixed effects were accounted for, case mix reimbursement was not associated with greater prevalence of feeding tube use. CONCLUSION The adoption of Medicaid case mix reimbursement was not associated with an increase in the prevalence of feeding tube use. PMID:18331293
NASA Astrophysics Data System (ADS)
Murphy, T. J.; Kyrala, G. A.; Bradley, P. A.; Krasheninnikova, N. S.; Cobble, J. A.; Tregillis, I. L.; Obrey, K. A. D.; Hsu, S. C.; Shah, R. C.; Hakel, P.; Kline, J. L.; Grim, G. P.; Baumgaertel, J. A.; Schmitt, M. J.; Kanzleiter, R. J.; Batha, S. H.
2013-10-01
Mix of shell material into ICF capsule fuel can degrade implosion performance through a number of mechanisms. One way is by dilution of the fusion fuel, which affects performance by an amount that is dependent on the degree of mix at the atomic level. Experiments are underway to quantify the mix of shell material into fuel using directly driven capsules on the National Ignition Facility. Deuterated plastic shells will be utilized with tritium fill so that the production of DT neutrons is indicative of mix at the atomic level. Neutron imaging will locate the burn region and spectroscopic imaging of the doped layers will reveal the location, temperature, and density of the shell material. Correlation of the two will be used to determine the degree of atomic mixing of the shell into the fuel and will be compared to models. This talk will review progress toward the development of an experimental platform to measure burn in the presence of measured mix. This work is supported by US DOE/NNSA, performed at LANL, operated by LANS LLC under contract DE-AC52-06NA25396.
Extracting a mix parameter from 2D radiography of variable density flow
NASA Astrophysics Data System (ADS)
Kurien, Susan; Doss, Forrest; Livescu, Daniel
2017-11-01
A methodology is presented for extracting quantities related to the statistical description of the mixing state from the 2D radiographic image of a flow. X-ray attenuation through a target flow is given by the Beer-Lambert law which exponentially damps the incident beam intensity by a factor proportional to the density, opacity and thickness of the target. By making reasonable assumptions for the mean density, opacity and effective thickness of the target flow, we estimate the contribution of density fluctuations to the attenuation. The fluctuations thus inferred may be used to form the correlation of density and specific-volume, averaged across the thickness of the flow in the direction of the beam. This correlation function, denoted by b in RANS modeling, quantifies turbulent mixing in variable density flows. The scheme is tested using DNS data computed for variable-density buoyancy-driven mixing. We quantify the deficits in the extracted value of b due to target thickness, Atwood number, and modeled noise in the incident beam. This analysis corroborates the proposed scheme to infer the mix parameter from thin targets at moderate to low Atwood numbers. The scheme is then applied to an image of counter-shear flow obtained from experiments at the National Ignition Facility. US Department of Energy.
NPDES Permit for City of Wagner Wastewater Treatment Facility in South Dakota
Under NPDES permit SD-0020184, the City of Wagner, South Dakota is authorized to discharge from its wastewater treatment facility in Charles Mix County, South Dakota, to an unnamed tributary of Choteau Creek.
18. Yards & Docks Drawing 112,447 (463A1) (1931), 'Battery Overhaul ...
18. Yards & Docks Drawing 112,447 (463-A-1) (1931), 'Battery Overhaul Bldg., Acid Mixing Plant & Misc. Details' - Mare Island Naval Shipyard, Acid Mixing Facility, California Avenue & E Street, Vallejo, Solano County, CA
NPDES Permit for Super Concrete Ready-Mix Corp. (Aggregate Industries)
Under National Pollutant Discharge Elimination System permit number DC0000175, Super Concrete Ready-Mix Corporation is authorized to discharge from a facility to receiving waters named unnamed tributary to Northwest Branch of the Anacostia River.
Texas cracking performance prediction, simulation, and binder recommendation.
DOT National Transportation Integrated Search
2014-10-01
Recent studies show some mixes with softer binders used outside of Texas (e.g., Minnesotas Cold Weather Road Research Facility mixes) have both good rutting and cracking performance. However, the current binder performance grading (PG) system fail...
NASA Technical Reports Server (NTRS)
1998-01-01
NASA engineers successfully tested a Russian-built rocket engine on November 4, 1998 at the Marshall Space Flight Center (MSFC) Advanced Engine Test Facility, which had been used for testing the Saturn V F-1 engines and Space Shuttle Main engines. The MSFC was under a Space Act Agreement with Lockheed Martin Astronautics of Denver to provide a series of test firings of the Atlas III propulsion system configured with the Russian-designed RD-180 engine. The tests were designed to measure the performance of the Atlas III propulsion system, which included avionics and propellant tanks and lines, and how these components interacted with the RD-180 engine. The RD-180 is powered by kerosene and liquid oxygen, the same fuel mix used in Saturn rockets. The RD-180, the most powerful rocket engine tested at the MSFC since Saturn rocket tests in the 1960s, generated 860,000 pounds of thrust. The test was the first test ever anywhere outside Russia of a Russian designed and built engine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Venkataraman, M.; Natarajan, R.; Raj, Baldev
The reprocessing of spent fuel from Fast Breeder Test Reactor (FBTR) has been successfully demonstrated in the pilot plant, CORAL (COmpact Reprocessing facility for Advanced fuels in Lead shielded cell). Since commissioning in 2003, spent mixed carbide fuel from FBTR of different burnups and varying cooling period, have been reprocessed in this facility. Reprocessing of the spent fuel with a maximum burnup of 100 GWd/t has been successfully carried out so far. The feed backs from these campaigns with progressively increasing specific activities, have been useful in establishing a viable process flowsheet for reprocessing the Prototype Fast Breeder Reactor (PFBR)more » spent fuel. Also, the design of various equipments and processes for the future plants, which are either under design for construction, namely, the Demonstration Fast Reactor Fuel Reprocessing Plant (DFRP) and the Fast reactor fuel Reprocessing Plant (FRP) could be finalized. (authors)« less
IBM-2 calculation with configuration mixing for Ge isotopes
NASA Astrophysics Data System (ADS)
Padilla-Rodal, Elizabeth; Galindo-Uribarri, Alfredo
2005-04-01
Recent results on Coulomb excitation experiments of radioactive neutron-rich Ge isotopes at the Holifield Radioactive Ion Beam Facility allow the study of the systematic trend of B(E2; 0^+ ->2^+) between the sub-shell closures at N=40 and the N=50 [1]. The new information on the E2 transition strengths constitutes a stringent test for the nuclear models and has motivated us to revisit the use of Interacting Boson Model in this region. We show that the IBM-2 with configuration mixing is a successful model to describe the shape transition phenomena that take place around N=40 in stable germanium isotopes, as well as the predictions given by this model about the evolution of the structure for the radioactive ^78, 80, 82Ge nuclei. [1] E. Padilla-Rodal Ph.D. Thesis UNAM; submitted for publication.
Vulnerability of CMOS image sensors in Megajoule Class Laser harsh environment.
Goiffon, V; Girard, S; Chabane, A; Paillet, P; Magnan, P; Cervantes, P; Martin-Gonthier, P; Baggio, J; Estribeau, M; Bourgade, J-L; Darbon, S; Rousseau, A; Glebov, V Yu; Pien, G; Sangster, T C
2012-08-27
CMOS image sensors (CIS) are promising candidates as part of optical imagers for the plasma diagnostics devoted to the study of fusion by inertial confinement. However, the harsh radiative environment of Megajoule Class Lasers threatens the performances of these optical sensors. In this paper, the vulnerability of CIS to the transient and mixed pulsed radiation environment associated with such facilities is investigated during an experiment at the OMEGA facility at the Laboratory for Laser Energetics (LLE), Rochester, NY, USA. The transient and permanent effects of the 14 MeV neutron pulse on CIS are presented. The behavior of the tested CIS shows that active pixel sensors (APS) exhibit a better hardness to this harsh environment than a CCD. A first order extrapolation of the reported results to the higher level of radiation expected for Megajoule Class Laser facilities (Laser Megajoule in France or National Ignition Facility in the USA) shows that temporarily saturated pixels due to transient neutron-induced single event effects will be the major issue for the development of radiation-tolerant plasma diagnostic instruments whereas the permanent degradation of the CIS related to displacement damage or total ionizing dose effects could be reduced by applying well known mitigation techniques.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kwon, Tae-Soon; Yun, Byong-Jo; Euh, Dong-Jin
Multidimensional thermal-hydraulic behavior in the downcomer annulus of a pressurized water reactor (PWR) vessel with a direct vessel injection mode is presented based on the experimental observation in the MIDAS (multidimensional investigation in downcomer annulus simulation) steam-water test facility. From the steady-state test results to simulate the late reflood phase of a large-break loss-of-coolant accident (LBLOCA), isothermal lines show the multidimensional phenomena of a phasic interaction between steam and water in the downcomer annulus very well. MIDAS is a steam-water separate effect test facility, which is 1/4.93 linearly scaled down to a 1400-MW(electric) PWR type of a nuclear reactor, focusedmore » on understanding multidimensional thermal-hydraulic phenomena in a downcomer annulus with various types of safety injection during the refill or reflood phase of an LBLOCA. The initial and the boundary conditions are scaled from the pretest analysis based on the preliminary calculation using the TRAC code. The superheated steam with a superheating degree of 80 K at a given downcomer pressure of 180 kPa is injected equally through three intact cold legs into the downcomer.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
JR Bontha; GR Golcar; N Hannigan
2000-08-29
The BNFL Inc. flowsheet for the pretreatment and vitrification of the Hanford High Level Tank waste includes the use of several hundred Reverse Flow Diverters (RFDs) for sampling and transferring the radioactive slurries and Pulsed Jet mixers to homogenize or suspend the tank contents. The Pulsed Jet mixing and the RFD sampling devices represent very simple and efficient methods to mix and sample slurries, respectively, using compressed air to achieve the desired operation. The equipment has no moving parts, which makes them very suitable for mixing and sampling highly radioactive wastes. However, the effectiveness of the mixing and sampling systemsmore » are yet to be demonstrated when dealing with Hanford slurries, which exhibit a wide range of physical and theological properties. This report describes the results of the testing of BNFL's Pulsed Jet mixing and RFD sampling systems in a 13-ft ID and 15-ft height dish-bottomed tank at Battelle's 336 building high-bay facility using AZ-101/102 simulants containing up to 36-wt% insoluble solids. The specific objectives of the work were to: Demonstrate the effectiveness of the Pulsed Jet mixing system to thoroughly homogenize Hanford-type slurries over a range of solids loading; Minimize/optimize air usage by changing sequencing of the Pulsed Jet mixers or by altering cycle times; and Demonstrate that the RFD sampler can obtain representative samples of the slurry up to the maximum RPP-WTP baseline concentration of 25-wt%.« less
Measuring School Facility Conditions: An Illustration of the Importance of Purpose
ERIC Educational Resources Information Center
Roberts, Lance W.
2009-01-01
Purpose: The purpose of this paper is to argue that taking the educational purposes of schools into account is central to understanding the place and importance of facilities to learning outcomes. The paper begins by observing that the research literature connecting facility conditions to student outcomes is mixed. A closer examination of this…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-08
... established pursuant to the policies duly authorized under the National Industrial Security Program. The proxy... Influence (FOCI) in order to maintain the Facility Security Clearance held by MOX Services. No physical... Facility Security Clearance, is in accordance with the provisions of the AEA of 1954, as amended. The...
Description and evaluation of an interference assessment for a slotted-wall wind tunnel
NASA Technical Reports Server (NTRS)
Kemp, William B., Jr.
1991-01-01
A wind-tunnel interference assessment method applicable to test sections with discrete finite-length wall slots is described. The method is based on high order panel method technology and uses mixed boundary conditions to satisfy both the tunnel geometry and wall pressure distributions measured in the slotted-wall region. Both the test model and its sting support system are represented by distributed singularities. The method yields interference corrections to the model test data as well as surveys through the interference field at arbitrary locations. These results include the equivalent of tunnel Mach calibration, longitudinal pressure gradient, tunnel flow angularity, wall interference, and an inviscid form of sting interference. Alternative results which omit the direct contribution of the sting are also produced. The method was applied to the National Transonic Facility at NASA Langley Research Center for both tunnel calibration tests and tests of two models of subsonic transport configurations.
A global reference for caesarean section rates (C-Model): a multicountry cross-sectional study.
Souza, J P; Betran, A P; Dumont, A; de Mucio, B; Gibbs Pickens, C M; Deneux-Tharaux, C; Ortiz-Panozo, E; Sullivan, E; Ota, E; Togoobaatar, G; Carroli, G; Knight, H; Zhang, J; Cecatti, J G; Vogel, J P; Jayaratne, K; Leal, M C; Gissler, M; Morisaki, N; Lack, N; Oladapo, O T; Tunçalp, Ö; Lumbiganon, P; Mori, R; Quintana, S; Costa Passos, A D; Marcolin, A C; Zongo, A; Blondel, B; Hernández, B; Hogue, C J; Prunet, C; Landman, C; Ochir, C; Cuesta, C; Pileggi-Castro, C; Walker, D; Alves, D; Abalos, E; Moises, Ecd; Vieira, E M; Duarte, G; Perdona, G; Gurol-Urganci, I; Takahiko, K; Moscovici, L; Campodonico, L; Oliveira-Ciabati, L; Laopaiboon, M; Danansuriya, M; Nakamura-Pereira, M; Costa, M L; Torloni, M R; Kramer, M R; Borges, P; Olkhanud, P B; Pérez-Cuevas, R; Agampodi, S B; Mittal, S; Serruya, S; Bataglia, V; Li, Z; Temmerman, M; Gülmezoglu, A M
2016-02-01
To generate a global reference for caesarean section (CS) rates at health facilities. Cross-sectional study. Health facilities from 43 countries. Thirty eight thousand three hundred and twenty-four women giving birth from 22 countries for model building and 10,045,875 women giving birth from 43 countries for model testing. We hypothesised that mathematical models could determine the relationship between clinical-obstetric characteristics and CS. These models generated probabilities of CS that could be compared with the observed CS rates. We devised a three-step approach to generate the global benchmark of CS rates at health facilities: creation of a multi-country reference population, building mathematical models, and testing these models. Area under the ROC curves, diagnostic odds ratio, expected CS rate, observed CS rate. According to the different versions of the model, areas under the ROC curves suggested a good discriminatory capacity of C-Model, with summary estimates ranging from 0.832 to 0.844. The C-Model was able to generate expected CS rates adjusted for the case-mix of the obstetric population. We have also prepared an e-calculator to facilitate use of C-Model (www.who.int/reproductivehealth/publications/maternal_perinatal_health/c-model/en/). This article describes the development of a global reference for CS rates. Based on maternal characteristics, this tool was able to generate an individualised expected CS rate for health facilities or groups of health facilities. With C-Model, obstetric teams, health system managers, health facilities, health insurance companies, and governments can produce a customised reference CS rate for assessing use (and overuse) of CS. The C-Model provides a customized benchmark for caesarean section rates in health facilities and systems. © 2015 World Health Organization; licensed by John Wiley & Sons Ltd on behalf of Royal College of Obstetricians and Gynaecologists.
Hazardous Waste Cleanup: Kearfott Guidance & Navigation Corporation in Little Falls, New Jersey
Kearfott Guidance & Navigation Corp. manufactures navigation and guidance systems, gyroscopes, and other electro-mechanical products for the aerospace industry at its Little Falls, New Jersey facility. The facility is located in a mixed industrial
Nick, Ophelia; Bauer, Alexander; Küchenhoff, Helmut; Erhard, Michael H.
2017-01-01
When laboratory dogs are rehomed into private households, they experience an extreme change in their life situation. They leave their familiar, limited environment in the research facility and encounter a multitude of animate and inanimate stimuli in their new home. Although literature reports have described the experiences with rehoming as being mostly positive, scientific observations of the dogs in everyday situations have not been done. Hence, we conducted an observational test with 74 laboratory beagles 6 weeks after adoption in their new homes. This test included standardized tasks and elements; the dogs were observed during specific interactions with their new owners and during a walk. Furthermore, the owners of these 74 and of 71 additional dogs participated in standardized phone interviews 1 and 12 weeks after adoption, during which they answered questions about the dogs’ behavior in everyday situations. In the observational test, the dogs behaved mostly friendly towards humans and dogs, were tolerant during manipulations by the owner and were relaxed during the walk, even in traffic. Eighty percent (of n = 71) of the dogs walked well behaved on the leash without pulling. According to the interviews, the majority of the dogs showed desired, friendly and relaxed behavior, and the survey results reflected the bonding between dog and owner. The analysis of a possible influence of various factors (age, sex, origin, etc.) using mixed regression models confirmed the results from two previous behavior tests and interviews. Specifically, dogs that had been bred in the research facility scored significantly better than dogs that the research facility had purchased from commercial laboratory dog breeders (p = 0.0113). The results of this study demonstrate a successful adaptation of the rehomed beagles to their new life situation. PMID:28742824
Parry, S; Richardson, D; O'Shea, D; Sen, B; Kenny, R
2000-01-01
OBJECTIVE—To assess the diagnostic value of supine and upright carotid sinus massage in elderly patients. DESIGN—Prospective controlled cohort study. SETTING—Three inner city accident and emergency departments and a dedicated syncope facility. PATIENTS—1375 consecutive patients aged > 55 years presenting with unexplained syncope and drop attacks; 25 healthy controls. INTERVENTIONS—Bilateral supine carotid sinus massage, repeated in the 70° head up tilt position if the initial supine test was not diagnostic of cardioinhibitory and mixed carotid sinus hypersensitivity. MAIN OUTCOME MEASURES—Diagnosis of cardioinhibitory or mixed carotid sinus hypersensitivity; clinical characteristics of supine v upright positive groups. RESULTS—226 patients were excluded for contraindications to carotid sinus massage. Of 1149 patients undergoing massage, 223 (19%) had cardioinhibitory or mixed carotid sinus hypersensitivity; 70 (31%) of these had a positive response to massage with head up tilt following negative supine massage (95% confidence interval, 25.3% to 37.5%). None of the healthy controls showed carotid sinus hypersensitivity on erect or supine massage. The initially positive supine test had 74% specificity and 100% sensitivity; these were both 100% for the upright positive test. The clinical characteristics of the supine v upright positive subgroups were similar. CONCLUSIONS—The diagnosis of carotid sinus hypersensitivity amenable to treatment by pacing may be missed in one third of cases if only supine massage is performed. Massage should be done routinely in the head up tilt position if the initial supine test is negative. Keywords: carotid sinus; tilt table testing; syncope; elderly patients PMID:10618329
Results of the NASP Ames Integrated Mixing Hypersonic Engine (AIMHYE) Scramjet Test Program
NASA Technical Reports Server (NTRS)
Cavolowsky, John A.; Loomis, Mark P.; Deiwert, George S.
1995-01-01
This paper describes the test techniques and results from the National Aerospace Plane Government Work Package 53, the Ames Integrated Mixing Hypersonic Engine (AIMHYE) Scramjet Test program conducted in the NASA Ames 16-Inch Combustion Driven Shock Tunnel. This was a series of near full-scale scramjet combustor tests with the objective to obtain high speed combustor and nozzle data from an engine with injector configurations similar to the NASP E21 and E22a designs. The experimental test approach was to use a large combustor model (80-100% throat height) designed and fabricated for testing in the semi-free jet mode. The conditions tested were similar to the "blue book" conditions at Mach 12, 14, and 16. GWP 53 validated use of large, long test time impulse facilities, specifically the Ames 16-Inch Shock Tunnel, for high Mach number scramjet propulsion testing an integrated test rig (inlet, combustor, and nozzle). Discussion of key features of the test program will include: effects of the 2-D combustor inlet pressure profile; performance of large injectors' fueling system that included nozzlettes, base injection, and film cooling; and heat transfer measurements to the combustor. Significant instrumentation development and application efforts include the following: combustor force balance application for measurement of combustor drag for comparison with integrated point measurements of skin friction; nozzle metric strip for measuring thrust with comparison to integrated pressure measurements; and nonintrusive optical fiber-based diode laser absorption measurements of combustion products for determination of combustor performance. Direct measurements will be reported for specific test article configurations and compared with CFD solutions.
Bottlenecks and opportunities for delivering integrated pediatric HIV services in Nepal
Diese, Mulamba; Shrestha, Lexman; Pradhan, Birendra; Singh, Dipendra; Raaijmakers, Hendrikus; Kisesa, Annefrida; Chamla, Dick; Ntambue, Mukengeshayi Abel
2016-01-01
Background In children, integration of HIV in MNCH services has been shown to incr. ease uptake of early infant diagnosis. This article examines bottlenecks and opportunities for scaling up integrated pediatric HIV services in Nepal. Methods This is a descriptive study using both mixed qualitative and quantitative methods, conducted in January 2015 in 19 facilities in five regions of Nepal most affected by HIV epidemic. The qualitative methods comprised in-depth structured interviews with key informants (leadership of The National Center for AIDS and STD Control and National Public Health Laboratory, district management teams, medical officers in charge of health facilities and HIV clinics, frontline staff at antenatal care and HIV clinics and laboratory). The quantitative methods were used to abstract data of HIV-infected pregnant women seen between January and December 2014, HIV-exposed infants aged less than 12 months, and HIV infected children aged less than 15 years who were initiated HIV treatment from 2010 to 2014. Structured tools were used to collect data which were analysed using IBM SPSS. Results Of the 19 facilities assessed, 18(98%), 18(98%), 14(75%), and 11(58%) provided prevention of mother-to-child transmission (PMTCT), Expanded Program on Immunization (EPI), pediatric ART and nutrition rehabilitation services, respectively. However, only 1(5%) facility collected onsite dried blood spots (DBS) for PCR HIV testing and 6(32%) facilities provided counselling and referral for DBS. In 2014, of the 121 HIV-exposed infants recorded, only 21(17%) received PCR test. The median turnaround time of the PCR test results was 54 days. Of the 21 records with PCR test, 11(52.5%) were from PMTCT clinics, 7(33%) from Nutritional rehabilitation clinics, and 3(14.5%) from pediatric outpatient clinic. Conversely, 934 children were initiated ART between 2010 and 2014, of which 5% were infants and 29% aged between 1 and 5 years. 298(32%) had comorbidities of which 64% had malnutrition. A total of 534(57%) had tuberculosis (TB) status assessed of which 58(11%) had active TB. Infants had lowest retention (63%), high mortality (17.4%), and loss to follow-up (10.9%). Conclusion Few facilities collect DBS and few children receive PCR tests with limited linkage to ART. This has led to late ART initiation, comorbidities, including TB coinfections and poor outcomes. The results indicate that there are opportunities for improving HIV case finding among HIV-exposed infants in PMTCT, EPI, TB, and nutrition services if provider initiated testing and counselling at the point of service delivery is institutionalized in these settings. PMID:26945139
NASA Technical Reports Server (NTRS)
1989-01-01
One of NASA'S agency-wide goals is the commercial development of space. To further this goal NASA is implementing a policy whereby U.S. firms are encouraged to utilize NASA facilities to develop and test concepts having commercial potential. Goddard, in keeping with this policy, will make the facilities and capabilities described in this document available to private entities at a reduced cost and on a noninterference basis with internal NASA programs. Some of these facilities include: (1) the Vibration Test Facility; (2) the Battery Test Facility; (3) the Large Area Pulsed Solar Simulator Facility; (4) the High Voltage Testing Facility; (5) the Magnetic Field Component Test Facility; (6) the Spacecraft Magnetic Test Facility; (7) the High Capacity Centrifuge Facility; (8) the Acoustic Test Facility; (9) the Electromagnetic Interference Test Facility; (10) the Space Simulation Test Facility; (11) the Static/Dynamic Balance Facility; (12) the High Speed Centrifuge Facility; (13) the Optical Thin Film Deposition Facility; (14) the Gold Plating Facility; (15) the Paint Formulation and Application Laboratory; (16) the Propulsion Research Laboratory; (17) the Wallops Range Facility; (18) the Optical Instrument Assembly and Test Facility; (19) the Massively Parallel Processor Facility; (20) the X-Ray Diffraction and Scanning Auger Microscopy/Spectroscopy Laboratory; (21) the Parts Analysis Laboratory; (22) the Radiation Test Facility; (23) the Ainsworth Vacuum Balance Facility; (24) the Metallography Laboratory; (25) the Scanning Electron Microscope Laboratory; (26) the Organic Analysis Laboratory; (27) the Outgassing Test Facility; and (28) the Fatigue, Fracture Mechanics and Mechanical Testing Laboratory.
A Clear Success for International Transport of Plutonium and MOX Fuels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blachet, L.; Jacot, P.; Bariteau, J.P.
2006-07-01
An Agreement between the United States and Russia to eliminate 68 metric tons of surplus weapons-grade plutonium provided the basis for the United States government and its agency, the Department of Energy (DOE), to enter into contracts with industry leaders to fabricate mixed oxide (MOX) fuels (a blend of uranium oxide and plutonium oxide) for use in existing domestic commercial reactors. DOE contracted with Duke, COGEMA, Stone and Webster (DCS), a limited liability company comprised of Duke Energy, COGEMA Inc. and Stone and Webster to design a Mixed Oxide Fuel Fabrication Facility (MFFF) which would be built and operated atmore » the DOE Savannah River Site (SRS) near Aiken, South Carolina. During this same time frame, DOE commissioned fabrication and irradiation of lead test assemblies in one of the Mission Reactors to assist in obtaining NRC approval for batch implementation of MOX fuel prior to the operations phase of the MFFF facility. On February 2001, DOE directed DCS to initiate a pre-decisional investigation to determine means to obtain lead assemblies including all international options for manufacturing MOX fuels. This lead to implementation of the EUROFAB project and work was initiated in earnest on EUROFAB by DCS on November 7, 2003. (authors)« less
Performance of Waterless Concrete
NASA Technical Reports Server (NTRS)
Toutanji, Houssam; Evans, Steve; Grugel, Richard N.
2010-01-01
The development of permanent lunar bases is constrained by performance of construction materials and availability of in-situ resources. Concrete seems a suitable construction material for the lunar environment, but water, one of its major components, is an extremely scarce resource on the Moon. This study explores an alternative to hydraulic concrete by replacing the binding mix of concrete (cement and water) with sulfur. Sulfur is a volatile element on the lunar surface that can be extracted from lunar soils by heating. Sulfur concrete mixes were prepared to investigate the effect of extreme environmental conditions on the properties of sulfur concrete. A hypervelocity impact test was conducted, having as its target a 5-cm cubic sample of sulfur concrete. This item consisted of JSC-1 lunar regolith simulant (65%) and sulfur (35%). The sample was placed in the MSFC Impact Test Facility s Micro Light Gas Gun target chamber, and was struck by a 1-mm diameter (1.4e-03 g) aluminum projectile at 5.85 km/s. In addition, HZTERN code, provided by NASA was used to study the effectiveness of sulfur concrete when subjected to space radiation.
A Human-in-the-Loop Evaluation of Multi-Sector Planning in Mixed Equipage Airspace (MSP III)
NASA Technical Reports Server (NTRS)
Smith, Nancy; Prevot, Tom; Kessell, Angela; Homola, Jeff; Lee, Hwasoo; Mercer, Joey; Brasil, Connie; Mainini, Matt; Lee, Paul
2011-01-01
A human-in-the-loop (HITL) simulation was conducted in May 2010 to determine the feasibility and value 01 conducting multi-sector planning (MSP) operations in a mixed equipage environment. Aircraft were categorized as equipped or unequipped based on the presence or absence of an air-ground data communications (Data Comm) capability for receiving auto-loadable clearances and transfer of communication messages from the air navigation service provider (ANSP). The purpose of the study was to determine the feasibility and possible benefits of introducing multi-sector planning in a mixed equipage context, or whether Data Comm equipage was required for MSP operations. Each test scenario presented one of three different equipage levels to the controllers (10%, 50% or 90% equipped aircraft), so that the operational impact of different equipage levels could be observed. Operational feasibility assessment addressed two related questions: (1) are MSP operations feasible for unequipped aircraft, and (2) are they feasible in a mixed equipage context. Similarly, two categories of potential benefits were explored: (1) system performance improvements (e.g., throughput, workload) associated with MSP at different equipage levels, and (2) the possibility of providing differential service for equipage through MSP operations. Tool requirements (for both planning and controller stations), as well as planning and coordination procedures - within facility (traffic management unit/operational area) and within sector (R-Side/D-Side) - were two other topics addressed in the study. Overall, results suggested that MSP operations were feasible in a mixed equipage environment and that the tools were effective with both equipped and unequipped aircraft. Using the MSP tools, traffic management coordinators were able to manage controller task load, effectively balancing throughput with complexity and controller task load at each of the three equipage levels tested.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edwards, T.; Pareizs, J.; Coleman, C.
For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) tests the applicability of the digestion methods used by the DWPF Laboratory for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) Receipt samples and SRAT Product process control samples. DWPF SRAT samples are typically dissolved using a method referred to as the DWPF Cold Chemical or Cold Chem Method (CC), (see DWPF Procedure SW4- 15.201). Testing indicates that the CC method produced mixed results. The CC method did not result in complete dissolution of either the SRAT Receipt ormore » SRAT Product with some fine, dark solids remaining. However, elemental analyses did not reveal extreme biases for the major elements in the sludge when compared with analyses obtained following dissolution by hot aqua regia (AR) or sodium peroxide fusion (PF) methods. The CC elemental analyses agreed with the AR and PF methods well enough that it should be adequate for routine process control analyses in the DWPF after much more extensive side-by-side tests of the CC method and the PF method are performed on the first 10 SRAT cycles of the Sludge Batch 9 (SB9) campaign. The DWPF Laboratory should continue with their plans for further tests of the CC method during these 10 SRAT cycles.« less
Casey, D. T.; Smalyuk, V. A.; Tipton, R. E.; ...
2014-09-09
Surrogate implosions play an important role at the National Ignition Facility (NIF) for isolating aspects of the complex physical processes associated with fully integrated ignition experiments. The newly developed CD Symcap platform has been designed to study gas-shell mix in indirectly driven, pure T₂-gas filled CH-shell implosions equipped with 4 μm thick CD layers. This configuration provides a direct nuclear signature of mix as the DT yield (above a characterized D contamination background) is produced by D from the CD layer in the shell, mixing into the T-gas core. The CD layer can be placed at different locations within themore » CH shell to probe the depth and extent of mix. CD layers placed flush with the gas-shell interface and recessed up to 8 μm have shown that most of the mix occurs at the inner-shell surface. In addition, time-gated x-ray images of the hotspot show large brightly-radiating objects traversing through the hotspot around bang-time, which are likely chunks of CH/CD plastic. This platform is a powerful new capability at the NIF for understanding mix, one of the key performance issues for ignition experiments.« less
Daigger, Glen T; Siczka, John S; Smith, Thomas F; Frank, David A; McCorquodale, J A
The performance characteristics of relatively shallow (3.3 and 3.7 m sidewater depth in 30.5 m diameter) activated sludge secondary clarifiers were extensively evaluated during a 2-year testing program at the City of Akron Water Reclamation Facility (WRF), Ohio, USA. Testing included hydraulic and solids loading stress tests, and measurement of sludge characteristics (zone settling velocity (ZSV), dispersed and flocculated total suspended solids), and the results were used to calibrate computational fluid dynamic (CFD) models of the various clarifiers tested. The results demonstrated that good performance could be sustained at surface overflow rates in excess of 3 m/h, as long as the clarifier influent mixed liquor suspended solids (MLSS) concentration was controlled to below critical values. The limiting solids loading rate (SLR) was significantly lower than the value predicted by conventional solids flux analysis based on the measured ZSV/MLSS relationship. CFD analysis suggested that this resulted because mixed liquor entering the clarifier was being directed into the settled sludge blanket, diluting it and also creating a 'thin' concentration sludge blanket that overlays the thicker concentration sludge blanket typically expected. These results indicate the need to determine the allowable SLR for shallow clarifiers using approaches other than traditional solids flux analysis. A combination of actual testing and CFD analyses are demonstrated here to be effective in doing so.
NASA Technical Reports Server (NTRS)
Drozda, Tomasz G.; Axdahl, Erik L.; Cabell, Karen F.
2014-01-01
With the increasing costs of physics experiments and simultaneous increase in availability and maturity of computational tools it is not surprising that computational fluid dynamics (CFD) is playing an increasingly important role, not only in post-test investigations, but also in the early stages of experimental planning. This paper describes a CFD-based effort executed in close collaboration between computational fluid dynamicists and experimentalists to develop a virtual experiment during the early planning stages of the Enhanced Injection and Mixing project at NASA Langley Research Center. This projects aims to investigate supersonic combustion ramjet (scramjet) fuel injection and mixing physics, improve the understanding of underlying physical processes, and develop enhancement strategies and functional relationships relevant to flight Mach numbers greater than 8. The purpose of the virtual experiment was to provide flow field data to aid in the design of the experimental apparatus and the in-stream rake probes, to verify the nonintrusive measurements based on NO-PLIF, and to perform pre-test analysis of quantities obtainable from the experiment and CFD. The approach also allowed for the joint team to develop common data processing and analysis tools, and to test research ideas. The virtual experiment consisted of a series of Reynolds-averaged simulations (RAS). These simulations included the facility nozzle, the experimental apparatus with a baseline strut injector, and the test cabin. Pure helium and helium-air mixtures were used to determine the efficacy of different inert gases to model hydrogen injection. The results of the simulations were analyzed by computing mixing efficiency, total pressure recovery, and stream thrust potential. As the experimental effort progresses, the simulation results will be compared with the experimental data to calibrate the modeling constants present in the CFD and validate simulation fidelity. CFD will also be used to investigate different injector concepts, improve understanding of the flow structure and flow physics, and develop functional relationships. Both RAS and large eddy simulations (LES) are planned for post-test analysis of the experimental data.
Gedik, Ridvan; Zhang, Shengfan; Rainwater, Chase
2017-06-01
A relatively new consideration in proton therapy planning is the requirement that the mix of patients treated from different categories satisfy desired mix percentages. Deviations from these percentages and their impacts on operational capabilities are of particular interest to healthcare planners. In this study, we investigate intelligent ways of admitting patients to a proton therapy facility that maximize the total expected number of treatment sessions (fractions) delivered to patients in a planning period with stochastic patient arrivals and penalize the deviation from the patient mix restrictions. We propose a Markov Decision Process (MDP) model that provides very useful insights in determining the best patient admission policies in the case of an unexpected opening in the facility (i.e., no-shows, appointment cancellations, etc.). In order to overcome the curse of dimensionality for larger and more realistic instances, we propose an aggregate MDP model that is able to approximate optimal patient admission policies using the worded weight aggregation technique. Our models are applicable to healthcare treatment facilities throughout the United States, but are motivated by collaboration with the University of Florida Proton Therapy Institute (UFPTI).
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1994-12-31
This report contains information on radioactive mixed wastes at the Hanford Site. Information consists of shipment date, physical state, chemical nature, waste description, handling method and containment vessel, waste number, waste designation and amount of waste.
42 CFR 413.340 - Transition period.
Code of Federal Regulations, 2010 CFR
2010-10-01
... PROSPECTIVELY DETERMINED PAYMENT RATES FOR SKILLED NURSING FACILITIES Prospective Payment for Skilled Nursing... minus 1 percentage point. (c) SNFs participating in the Multistate Nursing Home Case-Mix and Quality Demonstration. SNFs that participated in the Multistate Nursing Home Case-Mix and Quality Demonstration in a...
42 CFR 413.340 - Transition period.
Code of Federal Regulations, 2013 CFR
2013-10-01
... PROSPECTIVELY DETERMINED PAYMENT RATES FOR SKILLED NURSING FACILITIES Prospective Payment for Skilled Nursing... minus 1 percentage point. (c) SNFs participating in the Multistate Nursing Home Case-Mix and Quality Demonstration. SNFs that participated in the Multistate Nursing Home Case-Mix and Quality Demonstration in a...
Woyessa, Adugna; Deressa, Wakgari; Ali, Ahmed; Lindtjørn, Bernt
2013-06-27
Malaria is a major public health problem in Ethiopia. Plasmodium falciparum and Plasmodium vivax co-exist and malaria rapid diagnostic test (RDTs) is vital in rendering parasite-confirmed treatment especially in areas where microscopy from 2008 to 2010 is not available. CareStartTM Malaria Pf/Pv combo test was evaluated compared to microscopy in Butajira area, south-central Ethiopia. This RDT detects histidine-rich protein-2 (HRP2) found in P. falciparum, and Plasmodium enzyme lactate dehydrogenase (pLDH) for diagnosis of P. vivax. The standard for the reporting of diagnostic accuracy studies was complied. Among 2,394 participants enrolled, 10.9% (n=87) were Plasmodium infected (household survey) and 24.5% (n=392) health facility-based using microscopy. In the household surveys, the highest positivity was caused by P. vivax (83.9%, n=73), P. falciparum (15.0%, n=13), and the rest due to mixed infections of both (1.1%, n=1). In health facility, P. vivax caused 78.6% (n=308), P. falciparum caused 20.4% (n=80), and the rest caused by mixed infections 1.0% (n=4). RDT missed 9.1% (n=8) in household and 4.3% (n=17) in health facility-based surveys among Plasmodium positive confirmed by microscopy while 3.3% (n=24) in household and 17.2% (n=208) in health facility-based surveys were detected false positive. RDT showed agreement with microscopy in detecting 79 positives in household surveys (n=796) and 375 positives in health centre survey (n=1,598).RDT performance varied in both survey settings, lowest PPV (64.3%) for Plasmodium and P. falciparum (77.2%) in health centres; and Plasmodium (76.7%) and P. falciparum (87.5%) in household surveys. NPV was low in P. vivax in health centres (77.2%) and household (87.5%) surveys. Seasonally varying RDT precision of as low as 14.3% PPV (Dec. 2009), and 38.5% NPV (Nov. 2008) in health centre surveys; and 40-63.6% PPV was observed in household surveys. But the influence of age and parasite density on RDT performance was not ascertained. Establishing quality control of malaria RDT in the health system in areas with low endemic and where P. falciparum and P. vivax co-exist is recommendable. CareStartTM RDT might be employed for epidemiological studies that require interpreting the results cautiously. Future RDT field evaluation against microscopy should be PCR corrected.
Altaras, Robin; Nuwa, Anthony; Agaba, Bosco; Streat, Elizabeth; Tibenderana, James K; Strachan, Clare E
2016-01-11
The large-scale introduction of malaria rapid diagnostic tests (RDTs) promises to improve management of fever patients and the rational use of valuable anti-malarials. However, evidence on the impact of RDT introduction on the overprescription of anti-malarials has been mixed. This study explored determinants of provider decision-making to prescribe anti-malarials following a negative RDT result. A qualitative study was conducted in a rural district in mid-western Uganda in 2011, ten months after RDT introduction. Prescriptions for all patients with negative RDT results were first audited from outpatient registers for a two month period at all facilities using RDTs (n = 30). Facilities were then ranked according to overall prescribing performance, defined as the proportion of patients with a negative RDT result prescribed any anti-malarial. Positive and negative deviant facilities were sampled for qualitative investigation; positive deviants (n = 5) were defined ex post facto as <0.75% and negative deviants (n = 7) as >5%. All prescribing clinicians were targeted for qualitative observation and in-depth interview; 55 fever cases were observed and 22 providers interviewed. Thematic analysis followed the 'framework' approach. 8344 RDT-negative patients were recorded at the 30 facilities (prescription audit); 339 (4.06%) were prescribed an anti-malarial. Of the 55 observed patients, 38 tested negative; one of these was prescribed an anti-malarial. Treatment decision-making was influenced by providers' clinical beliefs, capacity constraints, and perception of patient demands. Although providers generally trusted the accuracy of RDTs, anti-malarial prescription was driven by perceptions of treatment failure or undetectable malaria in patients who had already taken artemisinin-based combination therapy prior to facility arrival. Patient assessment and other diagnostic practices were minimal and providers demonstrated limited ability to identify alternative causes of fever. Provider perceptions of patient expectations sometimes appeared to influence treatment decisions. The study found high provider adherence to RDT results, but that providers believed in certain clinical exceptions and felt they lacked alternative options. Guidance on how the RDT works and testing following partial treatment, better methods for assisting providers in diagnostic decision-making, and a context-appropriate provider behaviour change intervention package are needed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, T.
Ten chemical processing cell (CPC) experiments were performed using simulant to evaluate Sludge Batch 9 for sludge-only and coupled processing using the nitric-formic flowsheet in the Defense Waste Processing Facility (DWPF). Sludge Receipt and Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) cycles were performed on eight of the ten. The other two were SRAT cycles only. Samples of the condensate, sludge, and off gas were taken to monitor the chemistry of the CPC experiments. The Savannah River National Laboratory (SRNL) has previously shown antifoam decomposes to form flammable organic products, (hexamethyldisiloxane (HMDSO), trimethylsilanol (TMS), and propanal), that are presentmore » in the vapor phase and condensate of the CPC vessels. To minimize antifoam degradation product formation, a new antifoam addition strategy was implemented at SRNL and DWPF to add antifoam undiluted.« less
Test Plan - Solids Accumulation Scouting Studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duignan, M. R.; Steeper, T. J.; Steimke, J. L.
This plan documents the highlights of the Solids Accumulations Scouting Studies test; a project, from Washington River Protection Solutions (WRPS), that began on February 1, 2012. During the last 12 weeks considerable progress has been made to design and plan methods that will be used to estimate the concentration and distribution of heavy fissile solids in accumulated solids in the Hanford double-shell tank (DST) 241-AW-105 (AW-105), which is the primary goal of this task. This DST will be one of the several waste feed delivery staging tanks designated to feed the Pretreatment Facility (PTF) of the Waste Treatment and Immobilizationmore » Plant (WTP). Note that over the length of the waste feed delivery mission AW-105 is currently identified as having the most fill empty cycles of any DST feed tanks, which is the reason for modeling this particular tank. At SRNL an existing test facility, the Mixing Demonstration Tank, which will be modified for the present work, will use stainless steel particles in a simulant that represents Hanford waste to perform mock staging tanks transfers that will allow solids to accumulate in the tank heel. The concentration and location of the mock fissile particles will be measured in these scoping studies to produce information that will be used to better plan larger scaled tests. Included in these studies is a secondary goal of developing measurement methods to accomplish the primary goal. These methods will be evaluated for use in the larger scale experiments. Included in this plan are the several pretest activities that will validate the measurement techniques that are currently in various phases of construction. Aspects of each technique, e.g., particle separations, volume determinations, topographical mapping, and core sampling, have been tested in bench-top trials, as discussed herein, but the actual equipment to be employed during the full test will need evaluation after fabrication and integration into the test facility.« less
Shin, Eunkyung; Kim, Jin Seok; Oh, Kyung-Hwan; Oh, Sung Suck; Kwon, MunJu; Kim, Soojin; Park, Jungsun; Kwak, Hyo-Sun; Chung, Gyung Tae; Kim, Chul-Joong; Kim, Junyoung
2017-09-01
Hepatitis A virus (HAV), a major cause of acute hepatitis, has had the highest occurrence among group 1 nationally notifiable infectious diseases in Korea since 2010.Recently,the annual increase in the HAV infection rate among young adults has become a public health concern. The aim of this study was to describe an outbreak of acute hepatitis in a residential facility in April 2015 and to identify potential sources of this outbreak. Sera from all exposed residents were tested for anti-HAV IgM or IgG antibodies by ELISA. Clinical (sera and stool) and environmental samples were screened for the presence of HAV RNA using one-step RT-PCR and nested PCR. The VP3-VP1 regions of HAV were analyzed using the BLAST database and MEGA7 software. Of the 82 persons in the facility, 12 (14.6%, including 10 residents and 2 health care workers) were diagnosed with hepatitis A. Clinical symptoms were evident in 9 individuals, one of whom died, and the remaining four patients were asymptomatic. Traceback investigation revealed that HAV-RNA (genotype IA) was detected in the patients' stools and the groundwater used in the facility. We described an HAV outbreak in a facility for the disabled due to using a water supply that was mixed with contaminated groundwater. Therefore, HAV vaccination and periodic water inspections in group facilities should be emphasized to prevent HAV infection. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Murphy, T. J.; Douglas, M. R.; Fincke, J. R.; Olson, R. E.; Cobble, J. A.; Haines, B. M.; Hamilton, C. E.; Lee, M. N.; Oertel, J. A.; Parra-Vasquez, N. A. G.; Randolph, R. B.; Schmidt, D. W.; Shah, R. C.; Smidt, J. M.; Tregillis, I. L.
2016-05-01
Mix of ablator material into fuel of an ICF capsule adds non-burning material, diluting the fuel and reducing burn. The amount of the reduction is dependent in part on the morphology of the mix. A probability distribution function (PDF) burn model has been developed [6] that utilizes the average concentration of mixed materials as well as the variance in this quantity across cells provided by the BHR turbulent transport model [3] and its revisions [4] to describe the mix in terms of a PDF of concentrations of fuel and ablator material, and provides the burn rate in mixed material. Work is underway to develop the MARBLE ICF platform for use on the National Ignition Facility in experiments to quantify the influence of heterogeneous mix on fusion burn. This platform consists of a plastic (CH) capsule filled with a deuterated plastic foam (CD) with a density of a few tens of milligrams per cubic centimeter, with tritium gas filling the voids in the foam. This capsule will be driven using x-ray drive on NIF, and the resulting shocks will induce turbulent mix that will result in the mixing of deuterium from the foam with the tritium gas. In order to affect the morphology of the mix, engineered foams with voids of diameter up to 100 microns will be utilized. The degree of mix will be determined from the ratio of DT to DD neutron yield. As the mix increases, the yield from reactions between the deuterium of the CD foam with tritium from the gas will increase. The ratio of DT to DD neutrons will be compared to a variation of the PDF burn model that quantifies reactions from initially separated reactants.
42 CFR 413.340 - Transition period.
Code of Federal Regulations, 2014 CFR
2014-10-01
... PROSPECTIVELY DETERMINED PAYMENT RATES FOR SKILLED NURSING FACILITIES Prospective Payment for Skilled Nursing... the facility-specific rate. Allowable costs associated with exemptions, as described in § 413.30(e)(2... minus 1 percentage point. (c) SNFs participating in the Multistate Nursing Home Case-Mix and Quality...
42 CFR 413.340 - Transition period.
Code of Federal Regulations, 2012 CFR
2012-10-01
... PROSPECTIVELY DETERMINED PAYMENT RATES FOR SKILLED NURSING FACILITIES Prospective Payment for Skilled Nursing... the facility-specific rate. Allowable costs associated with exemptions, as described in § 413.30(e)(2... minus 1 percentage point. (c) SNFs participating in the Multistate Nursing Home Case-Mix and Quality...
42 CFR 413.340 - Transition period.
Code of Federal Regulations, 2011 CFR
2011-10-01
... PROSPECTIVELY DETERMINED PAYMENT RATES FOR SKILLED NURSING FACILITIES Prospective Payment for Skilled Nursing... the facility-specific rate. Allowable costs associated with exemptions, as described in § 413.30(e)(2... minus 1 percentage point. (c) SNFs participating in the Multistate Nursing Home Case-Mix and Quality...
Nitric-glycolic flowsheet testing for maximum hydrogen generation rate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martino, C. J.; Newell, J. D.; Williams, M. S.
The Defense Waste Processing Facility (DWPF) at the Savannah River Site is developing for implementation a flowsheet with a new reductant to replace formic acid. Glycolic acid has been tested over the past several years and found to effectively replace the function of formic acid in the DWPF chemical process. The nitric-glycolic flowsheet reduces mercury, significantly lowers the chemical generation of hydrogen and ammonia, allows purge reduction in the Sludge Receipt and Adjustment Tank (SRAT), stabilizes the pH and chemistry in the SRAT and the Slurry Mix Evaporator (SME), allows for effective adjustment of the SRAT/SME rheology, and is favorablemore » with respect to melter flammability. The objective of this work was to perform DWPF Chemical Process Cell (CPC) testing at conditions that would bound the catalytic hydrogen production for the nitric-glycolic flowsheet.« less
Plasma-Facing Component and Materials Testing for the NSTX-U
NASA Astrophysics Data System (ADS)
Jaworski, Michael; Brooks, A.; Gerhardt, S.; Loesser, D.; Mardenfeld, M.; Menard, J.; Gray, T.; Reinke, M.
2017-10-01
The NSTX-U Recovery Project is developing plasma-facing components for use in the divertor of NSTX-U. The extreme conditions of the NSTX-U divertor make it possible to stress even graphite surfaces to the material limits leading to the possibility of component failures. In addition, the complex, mixed-material environment of the NSTX-U due to the use of boron and lithium wall conditioning techniques creates significant uncertainties in the monitoring of the PFCs. A testing program has been developed to inform on the material and design limitations of the NSTX-U high-heat flux components. These tests include high-heat flux testing in electron beam facilities as well as plasma-based testing. The NSTX-U components could experience perpendicular heat fluxes as high as 45 MW/m2. Parallel heat fluxes onto leading edges could reach 475 MW/m2. The testing program and material survey plan will be presented. Work supported by DOE contract DE-AC02-09CH11466 and DE-AC05-00OR22725.
Development and applications of nondestructive evaluation at Marshall Space Flight Center
NASA Technical Reports Server (NTRS)
Whitaker, Ann F.
1990-01-01
A brief description of facility design and equipment, facility usage, and typical investigations are presented for the following: Surface Inspection Facility; Advanced Computer Tomography Inspection Station (ACTIS); NDE Data Evaluation Facility; Thermographic Test Development Facility; Radiographic Test Facility; Realtime Radiographic Test Facility; Eddy Current Research Facility; Acoustic Emission Monitoring System; Advanced Ultrasonic Test Station (AUTS); Ultrasonic Test Facility; and Computer Controlled Scanning (CONSCAN) System.
Chang, Soju; Pool, Vitali; O'Connell, Kathryn; Polder, Jacquelyn A; Iskander, John; Sweeney, Colleen; Ball, Robert; Braun, M Miles
2008-01-01
Errors involving the mix-up of tuberculin purified protein derivative (PPD) and vaccines leading to adverse reactions and unnecessary medical management have been reported previously. To determine the frequency of PPD-vaccine mix-ups reported to the US Vaccine Adverse Event Reporting System (VAERS) and the Adverse Event Reporting System (AERS), characterize adverse events and clusters involving mix-ups and describe reported contributory factors. We reviewed AERS reports from 1969 to 2005 and VAERS reports from 1990 to 2005. We defined a mix-up error event as an incident in which a single patient or a cluster of patients inadvertently received vaccine instead of a PPD product or received a PPD product instead of vaccine. We defined a cluster as inadvertent administration of PPD or vaccine products to more than one patient in the same facility within 1 month. Of 115 mix-up events identified, 101 involved inadvertent administration of vaccines instead of PPD. Product confusion involved PPD and multiple vaccines. The annual number of reported mix-ups increased from an average of one event per year in the early 1990s to an average of ten events per year in the early part of this decade. More than 240 adults and children were affected and the majority reported local injection site reactions. Four individuals were hospitalized (all recovered) after receiving the wrong products. Several patients were inappropriately started on tuberculosis prophylaxis as a result of a vaccine local reaction being interpreted as a positive tuberculin skin test. Reported potential contributory factors involved both system factors (e.g. similar packaging) and human errors (e.g. failure to read label before product administration). To prevent PPD-vaccine mix-ups, proper storage, handling and administration of vaccine and PPD products is necessary.
40 CFR 60.670 - Applicability and designation of affected facility.
Code of Federal Regulations, 2010 CFR
2010-07-01
... mineral processing plants: each crusher, grinding mill, screening operation, bucket elevator, belt... grinding mills at hot mix asphalt facilities that reduce the size of nonmetallic minerals embedded in... or grinding mills above ground; and wet material processing operations (as defined in § 60.671). (b...
Steady state RANS simulations of temperature fluctuations in single phase turbulent mixing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kickhofel, J.; Fokken, J.; Kapulla, R.
2012-07-01
Single phase turbulent mixing in nuclear power plant circuits where a strong temperature gradient is present is known to precipitate pipe failure due to thermal fatigue. Experiments in a square mixing channel offer the opportunity to study the phenomenon under simple and easily reproducible boundary conditions. Measurements of this kind have been performed extensively at the Paul Scherrer Inst. in Switzerland with a high density of instrumentation in the Generic Mixing Experiment (GEMIX). As a fundamental mixing phenomena study closely related to the thermal fatigue problem, the experimental results from GEMIX are valuable for the validation of CFD codes strivingmore » to accurately simulate both the temperature and velocity fields in single phase turbulent mixing. In the experiments two iso-kinetic streams meet at a shallow angle of 3 degrees and mix in a straight channel of square cross-section under various degrees of density, temperature, and viscosity stratification over a range of Reynolds numbers ranging from 5*10{sup 3} to 1*10{sup 5}. Conductivity measurements, using wire-mesh and wall sensors, as well as optical measurements, using particle image velocimetry, were conducted with high temporal and spatial resolutions (up to 2.5 kHz and 1 mm in the case of the wire mesh sensor) in the mixing zone, downstream of a splitter plate. The present paper communicates the results of RANS modeling of selected GEMIX tests. Steady-state CFD calculations using a RANS turbulence model represent an inexpensive method for analyzing large and complex components in commercial nuclear reactors, such as the downcomer and reactor pressure vessel heads. Crucial to real world applicability, however, is the ability to model turbulent heat fluctuations in the flow; the Turbulent Heat Flux Transport model developed by ANSYS CFX is capable, by implementation of a transport equation for turbulent heat fluxes, of readily modeling these values. Furthermore, the closure of the turbulent heat flux transport equation evokes a transport equation for the variance of the enthalpy. It is therefore possible to compare the modeled fluctuations of the liquid temperature directly with the scalar fluctuations recorded experimentally with the wire-mesh. Combined with a working Turbulent Heat Flux Transport model, complex mixing problems in large geometries could be better understood. We aim for the validation of Reynolds Stress based RANS simulations extended by the Turbulent Heat Flux Transport model by modeling the GEMIX experiments in detail. Numerical modeling has been performed using both BSL and SSG Reynolds Stress Models in a test matrix comprising experimental trials at the GEMIX facility. We expand on the turbulent mixing RANS CFD results of (Manera 2009) in a few ways. In the GEMIX facility we introduce density stratification in the flow while removing the characteristic large scale vorticity encountered in T-junctions and therefore find better conditions to check the diffusive conditions in the model. Furthermore, we study the performance of the model in a very different, simpler scalar fluctuation spectrum. The paper discusses the performance of the model regarding the dissipation of the turbulent kinetic energy and dissipation of the enthalpy variance. A novel element is the analyses of cases with density stratification. (authors)« less
Robey, H F; Amendt, P A; Milovich, J L; Park, H-S; Hamza, A V; Bono, M J
2009-10-02
High-convergence, hohlraum-driven implosions of double-shell capsules using mid-Z (SiO2) inner shells have been performed on the OMEGA laser facility [T. R. Boehly, Opt. Commun. 133, 495 (1997)]. These experiments provide an essential extension of the results of previous low-Z (CH) double-shell implosions [P. A. Amendt, Phys. Rev. Lett. 94, 065004 (2005)] to materials of higher density and atomic number. Analytic modeling, supported by highly resolved 2D numerical simulations, is used to account for the yield degradation due to interfacial atomic mixing. This extended experimental database from OMEGA enables a validation of the mix model, and provides a means for quantitatively assessing the prospects for high-Z double-shell implosions on the National Ignition Facility [Paisner, Laser Focus World 30, 75 (1994)].
Lacoste, V; Gressier, V
2007-01-01
The Institute for Radiological Protection and Nuclear Safety owns two facilities producing realistic mixed neutron-photon radiation fields, CANEL, an accelerator driven moderator modular device, and SIGMA, a graphite moderated americium-beryllium assembly. These fields are representative of some of those encountered at nuclear workplaces, and the corresponding facilities are designed and used for calibration of various instruments, such as survey meters, personal dosimeters or spectrometric devices. In the framework of the European project EVIDOS, irradiations of personal dosimeters were performed at CANEL and SIGMA. Monte Carlo calculations were performed to estimate the reference values of the personal dose equivalent at both facilities. The Hp(10) values were calculated for three different angular positions, 0 degrees, 45 degrees and 75 degrees, of an ICRU phantom located at the position of irradiation.
The cement solidification systems at LANL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veazey, G.W.
1990-01-01
There are two major cement solidification systems at Los Alamos National Laboratory. Both are focused primarily around treating waste from the evaporator at TA-55, the Plutonium Processing Facility. The evaporator receives the liquid waste stream from TA-55's nitric acid-based, aqueous-processing operations and concentrates the majority of the radionuclides in the evaporator bottoms solution. This is sent to the TA-55 cementation system. The evaporator distillate is sent to the TA-50 facility, where the radionuclides are precipitated and then cemented. Both systems treat TRU-level waste, and so are operated according to the criteria for WIPP-destined waste, but they differ in both cementmore » type and mixing method. The TA-55 systems uses Envirostone, a gypsum-based cement and in-drum prop mixing; the TA-50 systems uses Portland cement and drum tumbling for mixing.« less
Simulation of air-droplet mixed phase flow in icing wind-tunnel
NASA Astrophysics Data System (ADS)
Mengyao, Leng; Shinan, Chang; Menglong, Wu; Yunhang, Li
2013-07-01
Icing wind-tunnel is the main ground facility for the research of aircraft icing, which is different from normal wind-tunnel for its refrigeration system and spraying system. In stable section of icing wind-tunnel, the original parameters of droplets and air are different, for example, to keep the nozzles from freezing, the droplets are heated while the temperature of air is low. It means that complex mass and heat transfer as well as dynamic interactive force would happen between droplets and air, and the parameters of droplet will acutely change along the passageway. Therefore, the prediction of droplet-air mixed phase flow is necessary in the evaluation of icing researching wind-tunnel. In this paper, a simplified droplet-air mixed phase flow model based on Lagrangian method was built. The variation of temperature, diameter and velocity of droplet, as well as the air flow field, during the flow process were obtained under different condition. With calculating three-dimensional air flow field by FLUENT, the droplet could be traced and the droplet distribution could also be achieved. Furthermore, the patterns about how initial parameters affect the parameters in test section were achieved. The numerical simulation solving the flow and heat and mass transfer characteristics in the mixing process is valuable for the optimization of experimental parameters design and equipment adjustment.
Depth and Extent of Gas-Ablator Mix in Symcap Implosions at the National Ignition Facility
NASA Astrophysics Data System (ADS)
Pino, Jesse; Ma, T.; MacLaren, S. A.; Salmonson, J. D.; Ho, D.; Khan, S. F.; Masse, L.; Ralph, J. E.; Czajka, C.; Casey, D.; Sacks, R.; Smalyuk, V. A.; Tipton, R. E.; Kyrala, G. A.
2017-10-01
A longstanding question in ICF physics has been the extent to which capsule ablator material mixes into the burning fusion fuel and degrades performance. Several recent campaigns at the National Ignition Facility have examined this question through the use of separated reactants. A layer of CD plastic is placed on the inner surface of the CH shell and the shell is filled with a gas mixture of H and T. This allows for simultaneous neutron signals that inform different aspects of the physics; we get core TT neutron yield, atomic mix from the DT neutrons, and information about shell heating from the DD neutron signal. By systematically recessing the CD layer away from the gas boundary we gain an inference of the depth of the mixing layer. This presentation will cover three campaigns to look at mixing depth: An ignition-like design (``Low-foot'') at two convergence ratios, as well as a robust, nearly one-dimensional, low convergence, symmetric platform designed to minimize ablation front feed-through (HED 2-shock). We show that the 2-shock capsule has less ablator-gas mix, and compare the experimental results to mix-model simulations. This work was performed under the auspices of the U.S. Department of Energy by LLNL under Contract DE-AC52-07NA27344, LLNS, LLC.
Focusing-schlieren visualization in a dual-mode scramjet
NASA Astrophysics Data System (ADS)
Kouchi, Toshinori; Goyne, Christopher P.; Rockwell, Robert D.; McDaniel, James C.
2015-12-01
Schlieren imaging is particularly suited to measuring density gradients in compressible flowfields and can be used to capture shock waves and expansion fans, as well as the turbulent structures of mixing and wake flows. Conventional schlieren imaging, however, has difficulty clearly capturing such structures in long-duration supersonic combustion test facilities. This is because the severe flow temperatures locally change the refractive index of the window glass that is being used to provide optical access. On the other hand, focusing-schlieren imaging presents the potential of reduced sensitivity to thermal distortion of the windows and to clearly capture the flow structures even during a combustion test. This reduced sensitivity is due the technique's ability to achieve a narrow depth of focus. As part of this study, a focusing-schlieren system was developed with a depth of focus near ±5 mm and was applied to a direct-connect, continuous-flow type, supersonic combustion test facility with a stagnation temperature near 1200 K. The present system was used to successfully visualize the flowfield inside a dual-mode scramjet. The imaging system captured combustion-induced volumetric expansion of the fuel jet and an anchored bifurcated shock wave at the trailing edge of the ramp fuel injector. This is the first time successful focusing-schlieren measurements have been reported for a dual-mode scramjet.
Mixed mosaic membranes prepared by layer-by-layer assembly for ionic separations.
Rajesh, Sahadevan; Yan, Yu; Chang, Hsueh-Chia; Gao, Haifeng; Phillip, William A
2014-12-23
Charge mosaic membranes, which possess distinct cationic and anionic domains that traverse the membrane thickness, are capable of selectively separating dissolved salts from similarly sized neutral solutes. Here, the generation of charge mosaic membranes using facile layer-by-layer assembly methodologies is reported. Polymeric nanotubes with pore walls lined by positively charged polyethylenimine moieties or negatively charged poly(styrenesulfonate) moieties were prepared via layer-by-layer assembly using track-etched membranes as sacrificial templates. Subsequently, both types of nanotubes were deposited on a porous support in order to produce mixed mosaic membranes. Scanning electron microscopy demonstrates that the facile deposition techniques implemented result in nanotubes that are vertically aligned without overlap between adjacent elements. Furthermore, the nanotubes span the thickness of the mixed mosaic membranes. The effects of this unique nanostructure are reflected in the transport characteristics of the mixed mosaic membranes. The hydraulic permeability of the mixed mosaic membranes in piezodialysis operations was 8 L m(-2) h(-1) bar(-1). Importantly, solute rejection experiments demonstrate that the mixed mosaic membranes are more permeable to ionic solutes than similarly sized neutral molecules. In particular, negative rejection of sodium chloride is observed (i.e., the concentration of NaCl in the solution that permeates through a mixed mosaic membrane is higher than in the initial feed solution). These properties illustrate the ability of mixed mosaic membranes to permeate dissolved ions selectively without violating electroneutrality and suggest their utility in ionic separations.
40 CFR 266.220 - What does a storage and treatment conditional exemption do?
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Conditional Exemption for Low-Level Mixed Waste Storage... exemption exempts your low-level mixed waste from the regulatory definition of hazardous waste in 40 CFR 261...
42 CFR 412.620 - Patient classification system.
Code of Federal Regulations, 2013 CFR
2013-10-01
... weighting factors to reflect changes in— (1) Treatment patterns; (2) Technology; (3) Number of discharges... 42 Public Health 2 2013-10-01 2013-10-01 false Patient classification system. 412.620 Section 412... rehabilitation facilities into mutually exclusive case-mix groups. (2) For purposes of this subpart, case-mix...
42 CFR 412.620 - Patient classification system.
Code of Federal Regulations, 2012 CFR
2012-10-01
... weighting factors to reflect changes in— (1) Treatment patterns; (2) Technology; (3) Number of discharges... 42 Public Health 2 2012-10-01 2012-10-01 false Patient classification system. 412.620 Section 412... rehabilitation facilities into mutually exclusive case-mix groups. (2) For purposes of this subpart, case-mix...
42 CFR 412.620 - Patient classification system.
Code of Federal Regulations, 2014 CFR
2014-10-01
... weighting factors to reflect changes in— (1) Treatment patterns; (2) Technology; (3) Number of discharges... 42 Public Health 2 2014-10-01 2014-10-01 false Patient classification system. 412.620 Section 412... rehabilitation facilities into mutually exclusive case-mix groups. (2) For purposes of this subpart, case-mix...
Analysis of load-induced strains in a hot mix asphalt perpetual pavement : final report, April 2009.
DOT National Transportation Integrated Search
2009-04-01
This report presents the findings of a research study conducted to investigate the structural performance of a 275 mm hot : mix asphalt perpetual pavement constructed as part of the WIM bypass lane at the Kenosha Safety & Weigh Station : Facility. Tw...
NASA Technical Reports Server (NTRS)
Drozda, Tomasz G.; Baurle, Robert A.; Drummond, J. Philip
2016-01-01
The high total temperatures or total enthalpies required to duplicate the high-speed flight conditions in ground experiments often place stringent requirements on the material selection and cooling needs for the test articles and intrusive flow diagnostic equipment. Furthermore, for internal flows, these conditions often complicate the use of nonintrusive diagnostics that need optical access to the test section and interior portions of the flowpath. Because of the technical challenges and increased costs associated with experimentation at high values of total enthalpy, an attempt is often made to reduce it. This is the case for the Enhanced Injection and Mixing Project (EIMP) currently underway in the Arc-Heated Scramjet Test Facility at the NASA Langley Research Center. The EIMP aims to investigate supersonic combustion ramjet (scramjet) fuel injection and mixing physics, improve the understanding of underlying physical processes, and develop enhancement strategies and functional relationships between mixing performance and losses relevant to flight Mach numbers greater than 8. The experiments will consider a "direct-connect" approach and utilize a Mach 6 nozzle to simulate the combustor entrance flow of a scramjet engine. However, while the value of the Mach number is matched to that expected at the combustor entrance in flight, the maximum value of the total enthalpy for these experiments is limited by the thermal-structural limits of the uncooled experimental hardware. Furthermore, the fuel simulant is helium, not hydrogen. The use of "cold" flows and non-reacting mixtures of fuel simulants for mixing experiments is not new and has been extensively utilized as a screening technique for scramjet fuel injectors. In this study, Reynolds-averaged simulations are utilized (RAS) to systematically verify the implicit assumptions used by the EIMP. This is accomplished by first performing RAS of mixing for two injector configurations at planned nominal experimental conditions. The mixing parameters of interest, such as mixing efficiency and total pressure recovery, are then computed and compared to the values obtained from RAS under the true enthalpy conditions and using helium and hydrogen. Finally, the impact of combustion on mixing, often deemed small enough to neglect at hypervelocity conditions, is assessed by comparing the results obtained from the hydrogen-fueled reacting and non-reacting RAS. For reacting flows, in addition to mixing efficiency and total pressure recovery, the combustion efficiency and thrust potential are also considered. In all of the simulations, the incoming air Mach number and the fuel-to-air ratio are the same, while the total pressure, total enthalpy, and the fuel simulant vary depending on the case considered. It is found that under some conditions the "cold" flow experiments are a good approximation of the flight.
Small engine components test facility compressor testing cell at NASA Lewis Research Center
NASA Technical Reports Server (NTRS)
Brokopp, Richard A.; Gronski, Robert S.
1992-01-01
LeRC has designed and constructed a new test facility. This facility, called the Small Engine Components Facility (SECTF) is used to test gas turbines and compressors at conditions similar to actual engine conditions. The SECTF is comprised of a compressor testing cell and a turbine testing cell. Only the compressor testing cell is described. The capability of the facility, the overall facility design, the instrumentation used in the facility, and the data acquisition system are discussed in detail.
Casey, R; Chaix, B; Weber, C; Schweitzer, B; Charreire, H; Salze, P; Badariotti, D; Banos, A; Oppert, J-M; Simon, C
2012-07-01
Some characteristics of the built environment have been associated with obesity in youth. Our aim was to determine whether individual and environmental socio-economic characteristics modulate the relation between youth overweight and spatial accessibility to physical activity (PA) facilities and to food outlets. Cross-sectional study. 3293 students, aged 12 ± 0.6 years, randomly selected from eastern France middle schools. Using geographical information systems (GIS), spatial accessibility to PA facilities (urban and nature) was assessed using the distance to PA facilities at the municipality level; spatial accessibility to food outlets (general food outlets, bakeries and fast-food outlets) was calculated at individual level using the student home address and the food outlets addresses. Relations of weight status with spatial accessibility to PA facilities and to food outlets were analysed using mixed logistic models, testing potential direct and interaction effects of individual and environmental socio-economic characteristics. Individual socio-economic status modulated the relation between spatial accessibility to PA facilities and to general food outlets and overweight. The likelihood of being overweight was higher when spatial accessibility to urban PA facilities and to general food outlets was low, but in children of blue-collar-workers only. The odds ratio (OR) (95% confidence interval) for being overweight of blue-collar-workers children compared with non-blue-collar-workers children was 1.76 (1.25-2.49) when spatial accessibility to urban PA facilities was low. This OR was 1.86 (1.20-2.86) when spatial accessibility to general food outlets was low. There was no significant relationship of overweight with either nature PA facilities or other food outlets (bakeries and fast-food outlets). These results indicate that disparities in spatial accessibility to PA facilities and to general food outlets may amplify the risk of overweight in socio-economically disadvantaged youth. These data should be relevant for influencing health policies and urban planning at both a national and local level.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roscha, V.
1994-11-29
The purpose of this report is to describe the definitive design of the Radioactive Mixed Waste (RMW) Non-Drag-Off disposal facility, Project W-025. This report presents a n of the major landfill design features and a discussion of how each of the criteria is addressed in the design. The appendices include laboratory test results, design drawings, and individual analyses that were conducted in support of the design. Revision 1 of this document incorporates design changes resulting from an increase in the required operating life of the W-025 landfill from 2 to 20 years. The rationale for these design changes is describedmore » in Golder Associates Inc. 1991a. These changes include (1) adding a 1.5-foot-thick layer of compacted admix directory-under the primary FML on the floor of the landfill to mitigate the effects of possible stress cracking in the primary flexible membrane liner (FML), and (2) increasing the operations layer thickness from two to three feet over the entire landfill area, to provide additional protection for the secondary admix layer against mechanical damage and the effects of freezing and desiccation. The design of the W-025 Landfill has also been modified in response to the results of the EPA Method 9090 chemical compatibility testing program (Golder Associates Inc. 1991b and 1991c), which was completed after the original design was prepared. This program consisted of testing geosynthetic materials and soil/bentonite admix with synthetic leachate having the composition expected during the life of the W-025 Landfill., The results of this program indicated that the polyester geotextile originally specified for the landfill might be susceptible to deterioration. On this basis, polypropylene geotextiles were substituted as a more chemically-resistant alternative. In addition, the percentage of bentonite in the admix was increased to provide sufficiently low permeability to the expected leachate.« less
NASA Technical Reports Server (NTRS)
Williams, R. J.
1972-01-01
The details of the construction and operation of a gas mixing furnace are presented. A solid ceramic oxygen electrolyte cell is used to monitor the oxygen fugacity in the furnace. The system consists of a standard vertical-quench, gas mixing furnace with heads designed for mounting the electrolyte cell and with facilities for inserting and removing the samples. The system also contains the highinput impedance electronics necessary for measurements and a simplified version of standard gas mixing apparatus. The calibration and maintenance of the system are discussed.
Medicaid case-mix nursing home reimbursement in three states.
Swan, James H; Pickard, Ruth B
2003-01-01
Case-mix nursing facility payment raises issues of access, quality, equity, and cost. Case-mix should better match payment to costs, improve access, and provide incentives to increased staffing and quality of care; but it may also increase costs. This paper reports analysis of Medicaid cost-report data from three case-mix states. Case-mix did not discourage capacity building and was more equitable for providers. Medicaid access declined in one state but increased in another. There were shifts toward greater skilled care in two states, with evidence of greater focus of resources on patient care. Case-mix showed no evidence of cost-constraint and some signs of increased costs. Whether such mixed outcomes are viable in the current era remains to be seen.
DOE Office of Scientific and Technical Information (OSTI.GOV)
N /A
2000-06-30
The DOE proposes to construct, operate, and decontaminate/decommission a TRU Waste Treatment Facility in Oak Ridge, Tennessee. The four waste types that would be treated at the proposed facility would be remote-handled TRU mixed waste sludge, liquid low-level waste associated with the sludge, contact-handled TRU/alpha low-level waste solids, and remote-handled TRU/alpha low-level waste solids. The mixed waste sludge and some of the solid waste contain metals regulated under the Resource Conservation and Recovery Act and may be classified as mixed waste. This document analyzes the potential environmental impacts associated with five alternatives--No Action, the Low-Temperature Drying Alternative (Preferred Alternative), themore » Vitrification Alternative, the Cementation Alternative, and the Treatment and Waste Storage at Oak Ridge National Laboratory (ORNL) Alternative.« less
Diagnosing and controlling mix in National Ignition Facility implosion experiments a)
NASA Astrophysics Data System (ADS)
Hammel, B. A.; Scott, H. A.; Regan, S. P.; Cerjan, C.; Clark, D. S.; Edwards, M. J.; Epstein, R.; Glenzer, S. H.; Haan, S. W.; Izumi, N.; Koch, J. A.; Kyrala, G. A.; Landen, O. L.; Langer, S. H.; Peterson, K.; Smalyuk, V. A.; Suter, L. J.; Wilson, D. C.
2011-05-01
High mode number instability growth of "isolated defects" on the surfaces of National Ignition Facility [Moses et al., Phys. Plasmas 16, 041006 (2009)] capsules can be large enough for the perturbation to penetrate the imploding shell, and produce a jet of ablator material that enters the hot-spot. Since internal regions of the CH ablator are doped with Ge, mixing of this material into the hot-spot results in a clear signature of Ge K-shell emission. Evidence of jets entering the hot-spot has been recorded in x-ray images and spectra, consistent with simulation predictions [Hammel et al., High Energy Density Phys. 6, 171 (2010)]. Ignition targets have been designed to minimize instability growth, and capsule fabrication improvements are underway to reduce "isolated defects." An experimental strategy has been developed where the final requirements for ignition targets can be adjusted through direct measurements of mix and experimental tuning.
Space technology test facilities at the NASA Ames Research Center
NASA Technical Reports Server (NTRS)
Gross, Anthony R.; Rodrigues, Annette T.
1990-01-01
The major space research and technology test facilities at the NASA Ames Research Center are divided into five categories: General Purpose, Life Support, Computer-Based Simulation, High Energy, and the Space Exploraton Test Facilities. The paper discusses selected facilities within each of the five categories and discusses some of the major programs in which these facilities have been involved. Special attention is given to the 20-G Man-Rated Centrifuge, the Human Research Facility, the Plant Crop Growth Facility, the Numerical Aerodynamic Simulation Facility, the Arc-Jet Complex and Hypersonic Test Facility, the Infrared Detector and Cryogenic Test Facility, and the Mars Wind Tunnel. Each facility is described along with its objectives, test parameter ranges, and major current programs and applications.
40 CFR 160.43 - Test system care facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... testing facility shall have a number of animal rooms or other test system areas separate from those... GOOD LABORATORY PRACTICE STANDARDS Facilities § 160.43 Test system care facilities. (a) A testing facility shall have a sufficient number of animal rooms or other test system areas, as needed, to ensure...
40 CFR 160.43 - Test system care facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... testing facility shall have a number of animal rooms or other test system areas separate from those... GOOD LABORATORY PRACTICE STANDARDS Facilities § 160.43 Test system care facilities. (a) A testing facility shall have a sufficient number of animal rooms or other test system areas, as needed, to ensure...
2011-01-01
Background To facilitate access to the prevention of mother-to-child HIV transmission (PMTCT) services, HIV counselling and testing are offered routinely in antenatal care settings. Focusing a cohort of pregnant women attending public and private antenatal care facilities, this study applied an extended version of the Theory of Planned Behaviour (TPB) to explain intended- and actual HIV testing. Methods A sequential exploratory mixed methods study was conducted in Addis Ababa in 2009. The study involved first time antenatal attendees from public- and private health care facilities. Three Focus Group Discussions were conducted to inform the TPB questionnaire. A total of 3033 women completed the baseline TPB interviews, including attitudes, subjective norms, perceived behavioural control and intention with respect to HIV testing, whereas 2928 completed actual HIV testing at follow up. Data were analysed using descriptive statistics, Chi-square tests, Fisher's Exact tests, Internal consistency reliability, Pearson's correlation, Linear regression, Logistic regression and using Epidemiological indices. P-values < 0.05 was considered significant and 95% Confidence Interval (CI) was used for the odds ratio. Results The TPB explained 9.2% and 16.4% of the variance in intention among public- and private health facility attendees. Intention and perceived barriers explained 2.4% and external variables explained 7% of the total variance in HIV testing. Positive and negative predictive values of intention were 96% and 6% respectively. Across both groups, subjective norm explained a substantial amount of variance in intention, followed by attitudes. Women intended to test for HIV if they perceived social support and anticipated positive consequences following test performance. Type of counselling did not modify the link between intended and actual HIV testing. Conclusion The TPB explained substantial amount of variance in intention to test but was less sufficient in explaining actual HIV testing. This low explanatory power of TPB was mainly due to the large proportion of low intenders that ended up being tested contrary to their intention before entering the antenatal clinic. PMTCT programs should strengthen women's intention through social approval and information that testing will provide positive consequences for them. However, women's rights to opt-out should be emphasized in any attempt to improve the PMTCT programs. PMID:21851613
Vroling, Hilde; Babudieri, Sergio; Monarca, Roberto; Vonk Noordegraaf-Schouten, Marije; Beer, Netta; Gomes Dias, Joana; O’Moore, Éamonn; Hedrich, Dagmar; Oordt-Speets, Anouk
2018-01-01
Abstract Prison populations are disproportionally affected by communicable diseases when compared with the general community because of a complex mix of socioeconomic determinants and environmental factors. Tailored and adequate health care provision in prisons has the potential to reach vulnerable and underserved groups and address their complex needs. We investigated the available evidence on modalities and effectiveness of active case-finding interventions in prisons by searching PubMed, Embase, and the Cochrane Library for records on prison and active case finding with no language limit. Conference abstracts and unpublished research reports also were retrieved. We analyzed the findings by testing modality, outcomes, and study quality. The included 90 records—63 peer-reviewed, 26 from gray literature, and 1 systematic review—reported variously on viral hepatitis, human immunodeficiency virus, sexually transmitted infections, and tuberculosis. No records were retrieved for other communicable diseases. Provider-initiated opt-in testing was the most frequently investigated modality. Testing at entry and provider-initiated testing were reported to result in comparatively higher uptake ranges. However, no comparative studies were identified that reported statistically significant differences between testing modalities. Positivity rates among tested inmates ranged broadly but were generally high for all diseases. The evidence on active case finding in correctional facilities is limited, heterogeneous, and of low quality, making it challenging to draw conclusions on the effect of different testing modalities. Scale-up of provider-initiated testing in European correctional facilities could substantially reduce the undiagnosed fraction and, hence, prevent additional disease transmission in both prison settings and the community at large. PMID:29648594
NASA Astrophysics Data System (ADS)
Roslyakov, P. V.; Morozov, I. V.; Zaychenko, M. N.; Sidorkin, V. T.
2016-04-01
Various variants for the structure of low-emission burner facilities, which are meant for char gas burning in an operating TP-101 boiler of the Estonia power plant, are considered. The planned increase in volumes of shale reprocessing and, correspondingly, a rise in char gas volumes cause the necessity in their cocombustion. In this connection, there was a need to develop a burner facility with a given capacity, which yields effective char gas burning with the fulfillment of reliability and environmental requirements. For this purpose, the burner structure base was based on the staging burning of fuel with the gas recirculation. As a result of the preliminary analysis of possible structure variants, three types of early well-operated burner facilities were chosen: vortex burner with the supply of recirculation gases into the secondary air, vortex burner with the baffle supply of recirculation gases between flows of the primary and secondary air, and burner facility with the vortex pilot burner. Optimum structural characteristics and operation parameters were determined using numerical experiments. These experiments using ANSYS CFX bundled software of computational hydrodynamics were carried out with simulation of mixing, ignition, and burning of char gas. Numerical experiments determined the structural and operation parameters, which gave effective char gas burning and corresponded to required environmental standard on nitrogen oxide emission, for every type of the burner facility. The burner facility for char gas burning with the pilot diffusion burner in the central part was developed and made subject to computation results. Preliminary verification nature tests on the TP-101 boiler showed that the actual content of nitrogen oxides in burner flames of char gas did not exceed a claimed concentration of 150 ppm (200 mg/m3).
Modeling of a Two-Phase Jet Pump with Phase Change, Shocks and Temperature-Dependent Properties
NASA Technical Reports Server (NTRS)
Sherif, S. A.
1998-01-01
One of the primary motivations behind this work is the attempt to understand the physics of a two-phase jet pump which constitutes part of a flow boiling test facility at NASA-Marshall. The flow boiling apparatus is intended to provide data necessary to design highly efficient two-phase thermal control systems for aerospace applications. The facility will also be capable of testing alternative refrigerants and evaluate their performance using various heat exchangers with enhanced surfaces. The test facility is also intended for use in evaluating single-phase performance of systems currently using CFC refrigerants. Literature dealing with jet pumps is abundant and covers a very wide array of application areas. Example application areas include vacuum pumps which are used in the food industry, power station work, and the chemical industry; ejector systems which have applications in the aircraft industry as cabin ventilators and for purposes of jet thrust augmentation; jet pumps which are used in the oil industry for oil well pumping; and steam-jet ejector refrigeration, to just name a few. Examples of work relevant to this investigation includes those of Fairuzov and Bredikhin (1995). While past researchers have been able to model the two-phase flow jet pump using the one-dimensional assumption with no shock waves and no phase change, there is no research known to the author apart from that of Anand (1992) who was able to account for condensation shocks. Thus, one of the objectives of this work is to model the dynamics of fluid interaction between a two-phase primary fluid and a subcooled liquid secondary fluid which is being injected employing atomizing spray injectors. The model developed accounts for phase transformations due to expansion, compression, and mixing. It also accounts for shock waves developing in the different parts of the jet pump as well as temperature and pressure dependencies of the fluid properties for both the primary two-phase mixture and the secondary subcooled liquid. The research effort on which this document partly reports described a relatively simple model capable of describing the performance of a two-phase flow jet pump. The model is based on the isentropic homogeneous expansion/compression hypothesis and is capable of fully incorporating the effects of shocks in both the mixing chamber and the throat/diffuser parts of the pump. The physical system chosen is identical to that experimentally tested by Fairuzov and Bredikhin (1995) and should therefore be relatively easy to validate.
Storing Data from Qweak--A Precision Measurement of the Proton's Weak Charge
NASA Astrophysics Data System (ADS)
Pote, Timothy
2008-10-01
The Qweak experiment will perform a precision measurement of the proton's parity violating weak charge at low Q-squared. The experiment will do so by measuring the asymmetry in parity-violating electron scattering. The proton's weak charge is directly related to the value of the weak mixing angle--a fundamental quantity in the Standard Model. The Standard Model makes a firm prediction for the value of the weak mixing angle and thus Qweak may provide insight into shortcomings in the SM. The Qweak experiment will run at Thomas Jefferson National Accelerator Facility in Newport News, VA. A database was designed to hold data directly related to the measurement of the proton's weak charge such as detector and beam monitor yield, asymmetry, and error as well as control structures such as the voltage across photomultiplier tubes and the temperature of the liquid hydrogen target. In order to test the database for speed and stability, it was filled with fake data that mimicked the data that Qweak is expected to collect. I will give a brief overview of the Qweak experiment and database design, and present data collected during these tests.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dearing, J.F.
The Subchannel Analysis of Blockages in Reactor Elements (SABRE) computer code, developed by the United Kingdom Atomic Energy Authority, is currently the only practical tool available for performing detailed analyses of velocity and temperature fields in the recirculating flow regions downstream of blockages in liquid-metal fast breeder reactor (LMFBR) pin bundles. SABRE is a subchannel analysis code; that is, it accurately represents the complex geometry of nuclear fuel pins arranged on a triangular lattice. The results of SABRE computational models are compared here with temperature data from two out-of-pile 19-pin test bundles from the Thermal-Hydraulic Out-of-Reactor Safety (THORS) Facility atmore » Oak Ridge National Laboratory. One of these bundles has a small central flow blockage (bundle 3A), while the other has a large edge blockage (bundle 5A). Values that give best agreement with experiment for the empirical thermal mixing correlation factor, FMIX, in SABRE are suggested. These values of FMIX are Reynolds-number dependent, however, indicating that the coded turbulent mixing correlation is not appropriate for wire-wrap pin bundles.« less
Optimal Facility Location Tool for Logistics Battle Command (LBC)
2015-08-01
64 Appendix B. VBA Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Appendix C. Story...should city planners have located emergency service facilities so that all households (the demand) had equal access to coverage?” The critical...programming language called Visual Basic for Applications ( VBA ). CPLEX is a commercial solver for linear, integer, and mixed integer linear programming problems
40 CFR 60.740 - Applicability and designation of affected facility.
Code of Federal Regulations, 2010 CFR
2010-07-01
... fraction; (3) Web coating operations that print an image on the surface of the substrate or any coating... coating operation and any onsite coating mix preparation equipment used to prepare coatings for the... coatings at one plant for shipment to another plant for use in an affected facility (coating operation) or...
40 CFR 60.372 - Standards for lead.
Code of Federal Regulations, 2010 CFR
2010-07-01
... subpart shall cause to be discharged into the atmosphere: (1) From any grid casting facility any gases that contain lead in excess of 0.40 milligram of lead per dry standard cubic meter of exhaust (0.000175 gr/dscf). (2) From any paste mixing facility any gases that contain in excess of 1.00 milligram of...
40 CFR 266.350 - What records must you keep at your facility and for how long?
Code of Federal Regulations, 2014 CFR
2014-07-01
... after the exempted waste is sent for disposal. (e) If you are not already subject to NRC, or NRC... AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Conditional Exemption for Low-Level Mixed Waste...
Engineering study for closure of 209E facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brevick, C.H.; Heys, W.H.; Johnson, E.D.
1997-07-07
This document is an engineering study for evaluating alternatives to determine the most cost effective closure plan for the 209E Facility, Critical Mass Laboratory. This laboratory is located in the 200 East Area of the Hanford Site and contains a Critical Assembly Room and a Mix room were criticality experiments were once performed.
NASA Astrophysics Data System (ADS)
Nowak, J. B.; Neuman, J. A.; Bahreini, R.; Middlebrook, A. M.; Holloway, J. S.; McKeen, S. A.; Parrish, D. D.; Ryerson, T. B.; Trainer, M.
2012-04-01
Observations from the NOAA WP-3D aircraft during CalNex in May and June 2010 are used to quantify ammonia (NH3) emissions from automobiles and dairy facilities in the California South Coast Air Basin (SoCAB) and assess their impact on particulate ammonium nitrate (NH4NO3) formation. These airborne measurements in the SoCAB are used to estimate automobile NH3 emissions, 62 ± 24 metric tons day-1, and dairy facility NH3 emissions, 33 ± 16 to 176 ± 88 metric tons day-1. Emission inventories agree with the observed automobile NH3:CO emission ratio, but substantially underpredict dairy facility NH3 emissions. Conditions observed downwind of the dairy facilities were always thermodynamically favorable for NH4NO3 formation due to high NH3 mixing ratios from the concentrated sources. Although automobile emissions generated lower NH3 mixing ratios, they also can thermodynamically favor NH4NO3 formation. As an aerosol control strategy, addressing the dairy NH3 source would have the larger impact on reducing SoCAB NH4NO3 formation.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-22
... NUCLEAR REGULATORY COMMISSION [Docket No. 70-3098; NRC-2011-0081] Shaw AREVA MOX Services, Mixed... following methods: Federal Rulemaking Web site: Go to http://www.regulations.gov and search for documents... publicly available documents related to this notice using the following methods: NRC's Public Document Room...
Investigation of transport process involved in FGD. Final repot, September 1, 1993--August 31, 1994
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kadambi, J.R.; Tien, J.S.; Yurteri, C.
1995-02-01
The objectives of this five year plan of study are to experimentally obtain a basic understanding of (1) turbulent flow structure of the mixing zone and it influence on particle dispersion, (2) the effect of particle loading on turbulent properties and mixing, (3) the effect of jet entrainment, (4) water spray-sorbent interaction, sorbent wetting and mixing, (5) investigate the flow field where certain ratios of jet velocity to flu gas velocity result in regions of negative flow and define onset o negative flow, and (6) sorbent reactivity in immediate mixing zone. In the first two years of the project amore » sorbent injection facility which can simulate the conditions encountered in COOLSIDE set up was designed and built. Non-intrusive laser based diagnostic tools PDA/LDA were used for flow characterization of particle laden jet in cocurrent flows. In the third year a new technique called TTLDV which combines particle transit time in measurement volume of LDV and LDV velocity measurements to simultaneously obtain non-spherical lime particle size and velocity was developed. Better sorbent injection schemes were investigated spray occurrent flow tests were conducted. During the fourth year the spray cocurrent flow interaction data was analyzed. A criterion was developed for predicting the flow reversal which results in deposition of water droplets on the duct wall (Table 3). The flow reversal occurs when the spray has entrained all the cocurrent flowing stream. The criterion is based upon the mass flow rate of the two phases. The criterion successfully predicted the flow reversals encountered in the experiments and will be a very useful practical tool. Lime laden jet occurrent flow interactions tests were completed. Tests on the swirling nozzle have been conducted. The single phase data have been analyzed while the two phase glass particle laden jet data is being analyzed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-01-01
Through the National Governors' Association (NGA) project ''Critical Issues Related to Radioactive Waste and Materials Disposition Involving DOE Facilities'' NGA brings together Governors' policy advisors, state regulators, and DOE officials to examine critical issues related to the cleanup and operation of DOE nuclear weapons and research facilities. Topics explored through this project include: Decisions involving disposal of mixed, low-level, and transuranic (TRU) waste and disposition of nuclear materials. Decisions involving DOE budget requests and their effect on environmental cleanup and compliance at DOE facilities. Strategies to treat mixed, low-level, and transuranic (TRU) waste and their effect on individual sites inmore » the complex. Changes to the FFCA site treatment plans as a result of proposals in the EM 2006 cleanup plans and contractor integration analysis. Interstate waste and materials shipments. Reforms to existing RCRA and CERCLA regulations/guidance to address regulatory overlap and risks posed by DOE wastes. The overarching theme of this project is to help the Department improve coordination of its major program decisions with Governors' offices and state regulators and to ensure such decisions reflect input from these key state officials and stakeholders. This report summarizes activities conducted during the quarter from October 1, 1997 through December 31, 1997, under the NGA project. The work accomplished by the NGA project team during the past four months can be categorized as follows: maintained open communication with DOE on a variety of activities and issues within the DOE environmental management complex; and maintained communication with NGA Federal Facilities Compliance Task Force members regarding DOE efforts to formulate a configuration for mixed low-level waste and low-level treatment and disposal, DOE activities in the area of the Hazardous Waste Identification Rule, and DOE's proposed National Dialogue.« less
Bohren, Meghan A; Vogel, Joshua P; Hunter, Erin C; Lutsiv, Olha; Makh, Suprita K; Souza, João Paulo; Aguiar, Carolina; Saraiva Coneglian, Fernando; Diniz, Alex Luíz Araújo; Tunçalp, Özge; Javadi, Dena; Oladapo, Olufemi T; Khosla, Rajat; Hindin, Michelle J; Gülmezoglu, A Metin
2015-06-01
Despite growing recognition of neglectful, abusive, and disrespectful treatment of women during childbirth in health facilities, there is no consensus at a global level on how these occurrences are defined and measured. This mixed-methods systematic review aims to synthesize qualitative and quantitative evidence on the mistreatment of women during childbirth in health facilities to inform the development of an evidence-based typology of the phenomenon. We searched PubMed, CINAHL, and Embase databases and grey literature using a predetermined search strategy to identify qualitative, quantitative, and mixed-methods studies on the mistreatment of women during childbirth across all geographical and income-level settings. We used a thematic synthesis approach to synthesize the qualitative evidence and assessed the confidence in the qualitative review findings using the CERQual approach. In total, 65 studies were included from 34 countries. Qualitative findings were organized under seven domains: (1) physical abuse, (2) sexual abuse, (3) verbal abuse, (4) stigma and discrimination, (5) failure to meet professional standards of care, (6) poor rapport between women and providers, and (7) health system conditions and constraints. Due to high heterogeneity of the quantitative data, we were unable to conduct a meta-analysis; instead, we present descriptions of study characteristics, outcome measures, and results. Additional themes identified in the quantitative studies are integrated into the typology. This systematic review presents a comprehensive, evidence-based typology of the mistreatment of women during childbirth in health facilities, and demonstrates that mistreatment can occur at the level of interaction between the woman and provider, as well as through systemic failures at the health facility and health system levels. We propose this typology be adopted to describe the phenomenon and be used to develop measurement tools and inform future research, programs, and interventions.
10 CFR 26.123 - Testing facility capabilities.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Testing facility capabilities. 26.123 Section 26.123 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.123 Testing facility capabilities. Each licensee testing facility shall have the capability, at the same...
10 CFR 26.123 - Testing facility capabilities.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Testing facility capabilities. 26.123 Section 26.123 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.123 Testing facility capabilities. Each licensee testing facility shall have the capability, at the same...
10 CFR 26.123 - Testing facility capabilities.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Testing facility capabilities. 26.123 Section 26.123 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.123 Testing facility capabilities. Each licensee testing facility shall have the capability, at the same...
10 CFR 26.123 - Testing facility capabilities.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Testing facility capabilities. 26.123 Section 26.123 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.123 Testing facility capabilities. Each licensee testing facility shall have the capability, at the same...
10 CFR 26.123 - Testing facility capabilities.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Testing facility capabilities. 26.123 Section 26.123 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.123 Testing facility capabilities. Each licensee testing facility shall have the capability, at the same...
Does the presence and mix of destinations influence walking and physical activity?
King, Tania Louise; Bentley, Rebecca Jodie; Thornton, Lukar Ezra; Kavanagh, Anne Marie
2015-09-17
Local destinations have previously been shown to be associated with higher levels of both physical activity and walking, but little is known about how specific destinations are related to activity. This study examined associations between types and mix of destinations and both walking frequency and physical activity. The sample consisted of 2349 residents of 50 urban areas in metropolitan Melbourne, Australia. Using geographic information systems, seven types of destinations were examined within three network buffers (400 meters (m), 800 m and 1200 m) of respondents' homes. Multilevel logistic regression was used to estimate effects of each destination type separately, as well as destination mix (variety) on: 1) likelihood of walking for at least 10 min ≥ 4/week; 2) likelihood of being sufficiently physically active. All models were adjusted for potential confounders. All destination types were positively associated with walking frequency, and physical activity sufficiency at 1200 m. For the 800 m buffer: all destinations except transport stops and sports facilities were significantly associated with physical activity, while all except sports facilities were associated with walking frequency; at 400 m, café/takeaway food stores and transport stops were associated with walking frequency and physical activity sufficiency, and sports facilities were also associated with walking frequency. Strongest associations for both outcomes were observed for community resources and small food stores at both 800 m and 1200 m. For all buffer distances: greater mix was associated with greater walking frequency. Inclusion of walking in physical activity models led to attenuation of associations. The results of this analysis indicate that there is an association between destinations and both walking frequency and physical activity sufficiency, and that this relationship varies by destination type. It is also clear that greater mix of destinations positively predicts walking frequency and physical activity sufficiency.
Li, Huan; Liu, Xiangsheng; Huang, Nan; Ren, Kefeng; Jin, Qiao; Ji, Jian
2014-01-01
The acidic microenvironment of tumor tissues has proven to be one of the major differences from other normal tissues. The near-infrared (NIR) light irradiation of aggregated gold nanoparticles in a tumor acidic pH-induced manner could then provide an effect approach to treat solid tumors with the advantage of minimizing the undesired damage to normal tissues. Although it is well-known the aggregation of larger nanoparticles will result in a better NIR photothermal effect, the preparation of pH-sensitive gold nanoparticles in large sizes remains a big challenge because of their worse dispersive stability. In this paper, we introduce a facile way to endow large gold nanoparticles with tunable pH-aggregation behaviors by modifying the nanoparticle surface with mixed-charge self-assembly monolayers compromising positively and negatively charged thiol ligands. Four different size nanoparticles were used to study the general principle of tailoring the pH-induced aggregation behaviors of mixed-charge gold nanoparticles (MC-GNPs) by adjusting the surface ligand composition. With proper surface ligand composition, the MC-GNPs in four different sizes that all exhibited aggregation at tumor acidic pH were obtained. The biggest MC-GNPs showed the most encouraging aggregation-enhanced photothermal efficacy in vitro when they formed aggregates. The mixed-charge self-assembled monolayers were then proved as a facile method to design pH-induced aggregation of large gold nanoparticles for better NIR photothermal cancer therapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neeway, James J.; Pierce, Eric M.; Freedman, Vicky L.
2014-08-04
The federal facilities located on the Hanford Site in southeastern Washington State have been used extensively by the U.S. government to produce nuclear materials for the U.S. strategic defense arsenal. Currently, the Hanford Site is under the stewardship of the U.S. Department of Energy (DOE) Office of Environmental Management (EM). A large inventory of radioactive and mixed waste resulting from the production of nuclear materials has accumulated, mainly in 177 underground single- and double-shell tanks located in the central plateau of the Hanford Site (Mann et al., 2001). The DOE-EM Office of River Protection (ORP) is proceeding with plans tomore » immobilize and permanently dispose of the low-activity waste (LAW) fraction onsite in a shallow subsurface disposal facility (the Integrated Disposal Facility [IDF]). Pacific Northwest National Laboratory (PNNL) was contracted to provide the technical basis for estimating radionuclide release from the engineered portion of the IDF (the source term) as part of an immobilized low-activity waste (ILAW) glass testing program to support future IDF performance assessments (PAs).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
1999-09-01
Through efforts led by the Mixed Waste Focus Area (MWFA) and its Mercury Working Group (HgWG), the inventory of bulk elemental mercury contaminated with radionuclides stored at various U.S. Department of Energy (DOE) sites is thought to be approximately 16 m3 (Conley et al. 1998). At least 19 different DOE sites have this type of mixed low-level waste in their storage facilities. The U.S. Environmental Protection Agency (EPA) specifies amalgamation as the treatment method for radioactively contaminated elemental mercury. Although the chemistry of amalgamation is well known, the practical engineering of a sizable amalgamation process has not been tested (Tysonmore » 1993). To eliminate the existing DOE inventory in a reasonable timeframe, scalable equipment is needed that can produce waste forms that meet the EPA definition of amalgamation, produce waste forms that pass the EPA Toxicity Characteristic Leaching Procedure (TCLP) limit of 0.20 mg/L, limit mercury vapor concentrations during processing to below the Occupational Safety and Health Administration’s (OSHA) 8-h worker exposure limit (50 mg/m3) for mercury, and perform the above economically.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
1999-09-01
Through efforts led by the Mixed Waste Focus Area (MWFA) and its Mercury Working Group (HgWG), the inventory of bulk elemental mercury contaminated with radionuclides stored at various U. S. Department of Energy (DOE) sites is thought to be approximately 16 m3 (Conley et al. 1998). At least 19 different DOE sites have this type of mixed low-level waste in their storage facilities. The U. S. Environmental Protection Agency (EPA) specifies amalgamation as the treatment method for radioactively contaminated elemental mercury. Although the chemistry of amalgamation is well known, the practical engineering of a sizable amalgamation process has not beenmore » tested (Tyson 1993). To eliminate the existing DOE inventory in a reasonable timeframe, scaleable equipment is needed that can: produce waste forms that meet the EPA definition of amalgamation, produce waste forms that pass the EPA Toxicity Characteristic Leaching Procedure (TCLP) limit of 0.20 mg/L, limit mercury vapor concentrations during processing to below the Occupational Safety and Health Administration’s (OSHA) 8-hour worker exposure limit (50 mg/m3) for mercury, and perform the above economically.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murphy, T. J.; Douglas, M. R.; Fincke, J. R.
Mix of ablator material into fuel of an ICF capsule adds non-burning material, diluting the fuel and reducing burn. The amount of the reduction is dependent in part on the morphology of the mix. A probability distribution function (PDF) burn model has been developed [6] that utilizes the average concentration of mixed materials as well as the variance in this quantity across cells provided by the BHR turbulent transport model [3] and its revisions [4] to describe the mix in terms of a PDF of concentrations of fuel and ablator material, and provides the burn rate in mixed material. Workmore » is underway to develop the MARBLE ICF platform for use on the National Ignition Facility in experiments to quantify the influence of heterogeneous mix on fusion burn. This platform consists of a plastic (CH) capsule filled with a deuterated plastic foam (CD) with a density of a few tens of milligrams per cubic centimeter, with tritium gas filling the voids in the foam. This capsule will be driven using x-ray drive on NIF, and the resulting shocks will induce turbulent mix that will result in the mixing of deuterium from the foam with the tritium gas. In order to affect the morphology of the mix, engineered foams with voids of diameter up to 100 microns will be utilized. The degree of mix will be determined from the ratio of DT to DD neutron yield. As the mix increases, the yield from reactions between the deuterium of the CD foam with tritium from the gas will increase. Lastly, the ratio of DT to DD neutrons will be compared to a variation of the PDF burn model that quantifies reactions from initially separated reactants.« less
Murphy, T. J.; Douglas, M. R.; Fincke, J. R.; ...
2016-05-26
Mix of ablator material into fuel of an ICF capsule adds non-burning material, diluting the fuel and reducing burn. The amount of the reduction is dependent in part on the morphology of the mix. A probability distribution function (PDF) burn model has been developed [6] that utilizes the average concentration of mixed materials as well as the variance in this quantity across cells provided by the BHR turbulent transport model [3] and its revisions [4] to describe the mix in terms of a PDF of concentrations of fuel and ablator material, and provides the burn rate in mixed material. Workmore » is underway to develop the MARBLE ICF platform for use on the National Ignition Facility in experiments to quantify the influence of heterogeneous mix on fusion burn. This platform consists of a plastic (CH) capsule filled with a deuterated plastic foam (CD) with a density of a few tens of milligrams per cubic centimeter, with tritium gas filling the voids in the foam. This capsule will be driven using x-ray drive on NIF, and the resulting shocks will induce turbulent mix that will result in the mixing of deuterium from the foam with the tritium gas. In order to affect the morphology of the mix, engineered foams with voids of diameter up to 100 microns will be utilized. The degree of mix will be determined from the ratio of DT to DD neutron yield. As the mix increases, the yield from reactions between the deuterium of the CD foam with tritium from the gas will increase. Lastly, the ratio of DT to DD neutrons will be compared to a variation of the PDF burn model that quantifies reactions from initially separated reactants.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-04-01
Through the National Governors' Association (NGA) project ''Critical Issues Related to Radioactive Waste and Materials Disposition Involving DOE Facilities'' NGA brings together Governors' policy advisors, state regulators, and DOE officials to examine critical issues related to the cleanup and operation of DOE nuclear weapons and research facilities. Topics explored through this project include: Decisions involving disposal of mixed, low-level, and transuranic (TRU) waste and disposition of nuclear materials. Decisions involving DOE budget requests and their effect on environmental cleanup and compliance at DOE facilities. Strategies to treat mixed, low-level, and transuranic (TRU) waste and their effect on individual sites inmore » the complex. Changes to the FFCA site treatment plans as a result of proposals in DOE's Accelerating Cleanup: Paths to Closure strategy and contractor integration analysis. Interstate waste and materials shipments. Reforms to existing RCRA and CERCLA regulations/guidance to address regulatory overlap and risks posed by DOE wastes. The overarching theme of this project is to help the Department improve coordination of its major program decisions with Governors' offices and state regulators and to ensure such decisions reflect input from these key state officials and stakeholders. This report summarizes activities conducted during the quarter from December 31, 1997 through April 30, 1998 under the NGA project. The work accomplished by the NGA project team during the past four months can be categorized as follows: maintained open communication with DOE on a variety of activities and issues within the DOE environmental management complex; and provided ongoing support to state-DOE interactions in preparation for the March 30-31, 1998 NGA Federal Facilities Compliance Task Force Meeting with DOE. maintained communication with NGA Federal Facilities Compliance Task Force members regarding DOE efforts to formulate a configuration for mixed low-level waste and low-level treatment and disposal, DOE's Environmental Management Budget, and DOE's proposed Intersite Discussions.« less
Rundek, Tatjana; Brown, Scott C; Wang, Kefeng; Dong, Chuanhui; Farrell, Mary Beth; Heller, Gary V; Gornik, Heather L; Hutchisson, Marge; Needleman, Laurence; Benenati, James F; Jaff, Michael R; Meier, George H; Perese, Susana; Bendick, Phillip; Hamburg, Naomi M; Lohr, Joann M; LaPerna, Lucy; Leers, Steven A; Lilly, Michael P; Tegeler, Charles; Alexandrov, Andrei V; Katanick, Sandra L
2014-10-01
There is limited information on the accreditation status and geographic distribution of vascular testing facilities in the US. The Centers for Medicare & Medicaid Services (CMS) provide reimbursement to facilities regardless of accreditation status. The aims were to: (1) identify the proportion of Intersocietal Accreditation Commission (IAC) accredited vascular testing facilities in a 5% random national sample of Medicare beneficiaries receiving outpatient vascular testing services; (2) describe the geographic distribution of these facilities. The VALUE (Vascular Accreditation, Location & Utilization Evaluation) Study examines the proportion of IAC accredited facilities providing vascular testing procedures nationally, and the geographic distribution and utilization of these facilities. The data set containing all facilities that billed Medicare for outpatient vascular testing services in 2011 (5% CMS Outpatient Limited Data Set (LDS) file) was examined, and locations of outpatient vascular testing facilities were obtained from the 2011 CMS/Medicare Provider of Services (POS) file. Of 13,462 total vascular testing facilities billing Medicare for vascular testing procedures in a 5% random Outpatient LDS for the US in 2011, 13% (n=1730) of facilities were IAC accredited. The percentage of IAC accredited vascular testing facilities in the LDS file varied significantly by US region, p<0.0001: 26%, 12%, 11%, and 7% for the Northeast, South, Midwest, and Western regions, respectively. Findings suggest that the proportion of outpatient vascular testing facilities that are IAC accredited is low and varies by region. Increasing the number of accredited vascular testing facilities to improve test quality is a hypothesis that should be tested in future research. © The Author(s) 2014.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kang, H.M.; Pate, M.B.
1999-06-15
The report discusses miscibility, solubility, viscosity, and density data for the refrigerant hydrofluorocarbon (HFC)-236ea (or R-236ea) and four lubricants supplied by Exxon Corporation. The miscibility tests were performed in a test facility consisting of a series of miniature test cells submerged in a constant temperature bath, precisely controlled over a range of {minus}50 to 90 C. Critical solution temperatures obtained from the miscibility data are presented for each refrigerant/lubricant combination. Data for the R-236ea in each of the test lubricants have been collected for refrigerant concentrations of 10--90%. The raw data have been presented, and the results have been summarized.more » Solubility, viscosity, and density data were also obtained for R-236ea mixed with the same four oils for a refrigerant concentration range of 0--40 wt% refrigerant over a temperature range of 30--100 C.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoskinson, R.L.
1994-01-01
This report summarizes a study conducted using the Arc/Info{reg_sign} geographic information system (GIS) to analyze the criteria used for site selection for the Mixed and Low-Level Waste Treatment Facility (MLLWTF) and the Idaho Waste Processing Facility (IWPF). The purpose of the analyses was to determine, based on predefined criteria, the areas on the INEL that best satisfied the criteria. The coverages used in this study were produced by importing the AutoCAD files that produced the maps for a pre site selection draft report into the GIS. The files were then converted to Arc/Info{reg_sign} GIS format. The initial analysis was mademore » by considering all of the criteria as having equal importance in determining the areas of the INEL that would best satisfy the requirements. Another analysis emphasized four of the criteria as ``must`` criteria which had to be satisfied. Additional analyses considered other criteria that were considered for, but not included in the predefined criteria. This GIS analysis of the siting criteria for the IWPF and MLLWTF provides a logical, repeatable, and defensible approach to the determination of candidate locations for the facilities. The results of the analyses support the location of the Candidate Locations.« less
NASA Astrophysics Data System (ADS)
Topping, D.; Barley, M. H.; Bane, M.; Higham, N.; Aumont, B.; McFiggans, G.
2015-11-01
In this paper we describe the development and application of a new web based facility, UManSysProp (http://umansysprop.seaes.manchester.ac.uk), for automating predictions of molecular and atmospheric aerosol properties. Current facilities include: pure component vapour pressures, critical properties and sub-cooled densities of organic molecules; activity coefficient predictions for mixed inorganic-organic liquid systems; hygroscopic growth factors and CCN activation potential of mixed inorganic/organic aerosol particles; absorptive partitioning calculations with/without a treatment of non-ideality. The aim of this new facility is to provide a single point of reference for all properties relevant to atmospheric aerosol that have been checked for applicability to atmospheric compounds where possible. The group contribution approach allows users to upload molecular information in the form of SMILES strings and UManSysProp will automatically extract the relevant information for calculations. Built using open source chemical informatics, and hosted at the University of Manchester, the facilities are provided via a browser and device-friendly web-interface, or can be accessed using the user's own code via a JSON API. In this paper we demonstrate its use with specific examples that can be simulated using the web-browser interface.
ERIC Educational Resources Information Center
Murray, Ellen R.
2016-01-01
According to the literature, identifying and treating tuberculosis (TB) in correctional facilities have been problematic for the inmates and also for the communities into which inmates are released. The importance of training those who can identify this disease early into incarceration is vital to halt the transmission. Although some training has…
ERIC Educational Resources Information Center
Ho, Shyue-Yung; Chen, Wen-Te; Hsu, Wei-Ling
2017-01-01
Environmental education is essential for people to pursue sustainable development. In Taiwan, environmental education is taught to students until they graduate from junior high school. This study was conducted to establish an assessment system for junior high schools to select appropriate environmental education facilities and sites. A mix of…
40 CFR 266.350 - What records must you keep at your facility and for how long?
Code of Federal Regulations, 2010 CFR
2010-07-01
... three years after the exempted waste is sent for disposal. (e) If you are not already subject to NRC, or... AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Conditional Exemption for Low-Level Mixed Waste...
40 CFR 266.350 - What records must you keep at your facility and for how long?
Code of Federal Regulations, 2011 CFR
2011-07-01
... three years after the exempted waste is sent for disposal. (e) If you are not already subject to NRC, or... AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Conditional Exemption for Low-Level Mixed Waste...
NASA Technical Reports Server (NTRS)
1993-01-01
A description is given of each of the following Langley research and test facilities: 0.3-Meter Transonic Cryogenic Tunnel, 7-by 10-Foot High Speed Tunnel, 8-Foot Transonic Pressure Tunnel, 13-Inch Magnetic Suspension & Balance System, 14-by 22-Foot Subsonic Tunnel, 16-Foot Transonic Tunnel, 16-by 24-Inch Water Tunnel, 20-Foot Vertical Spin Tunnel, 30-by 60-Foot Wind Tunnel, Advanced Civil Transport Simulator (ACTS), Advanced Technology Research Laboratory, Aerospace Controls Research Laboratory (ACRL), Aerothermal Loads Complex, Aircraft Landing Dynamics Facility (ALDF), Avionics Integration Research Laboratory, Basic Aerodynamics Research Tunnel (BART), Compact Range Test Facility, Differential Maneuvering Simulator (DMS), Enhanced/Synthetic Vision & Spatial Displays Laboratory, Experimental Test Range (ETR) Flight Research Facility, General Aviation Simulator (GAS), High Intensity Radiated Fields Facility, Human Engineering Methods Laboratory, Hypersonic Facilities Complex, Impact Dynamics Research Facility, Jet Noise Laboratory & Anechoic Jet Facility, Light Alloy Laboratory, Low Frequency Antenna Test Facility, Low Turbulence Pressure Tunnel, Mechanics of Metals Laboratory, National Transonic Facility (NTF), NDE Research Laboratory, Polymers & Composites Laboratory, Pyrotechnic Test Facility, Quiet Flow Facility, Robotics Facilities, Scientific Visualization System, Scramjet Test Complex, Space Materials Research Laboratory, Space Simulation & Environmental Test Complex, Structural Dynamics Research Laboratory, Structural Dynamics Test Beds, Structures & Materials Research Laboratory, Supersonic Low Disturbance Pilot Tunnel, Thermal Acoustic Fatigue Apparatus (TAFA), Transonic Dynamics Tunnel (TDT), Transport Systems Research Vehicle, Unitary Plan Wind Tunnel, and the Visual Motion Simulator (VMS).
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-22
... Activities; Submission to OMB for Review and Approval; Comment Request; NSPS for Hot Mix Asphalt Facilities... in paper, will be made available for public viewing at http://www.regulations.gov as EPA receives... information about the electronic docket, go to www.regulations.gov . Title: NSPS for Hot Mix Asphalt...
None
2018-01-16
Another key aspect of the NNSS mission is Environmental Management program, which addresses the environmental legacy from historic nuclear weapons related activities while also ensuring the health and safety of present day workers, the public, and the environment as current and future missions are completed. The Area 5 Radioactive Waste Management site receives low-level and mixed low-level waste from some 28 different generators from across the DOE complex in support of the legacy clean-up DOE Environmental Management project. Without this capability, the DOE would not be able to complete the clean up and proper disposition of these wastes. The program includes environmental protection, compliance, and monitoring of the air, water, plants, animals, and cultural resources at the NNSS. Investigation and implementation of appropriate corrective actions to address the contaminated ground water facilities and soils resulting from historic nuclear testing activities, the demolition of abandoned nuclear facilities, as well as installation of ground water wells to identify and monitor the extent of ground water contamination.
NASA Astrophysics Data System (ADS)
Yeamans, C. B.; Gharibyan, N.
2016-11-01
At the National Ignition Facility, the diagnostic instrument manipulator-based neutron activation spectrometer is used as a diagnostic of implosion performance for inertial confinement fusion experiments. Additionally, it serves as a platform for independent neutronic experiments and may be connected to fast recording systems for neutron effect tests on active electronics. As an implosion diagnostic, the neutron activation spectrometers are used to quantify fluence of primary DT neutrons, downscattered neutrons, and neutrons above the primary DT neutron energy created by reactions of upscattered D and T in flight. At a primary neutron yield of 1015 and a downscattered fraction of neutrons in the 10-12 MeV energy range of 0.04, the downscattered neutron fraction can be measured to a relative uncertainty of 8%. Significant asymmetries in downscattered neutrons have been observed. Spectrometers have been designed and fielded to measure the tritium-tritium and deuterium-tritium neutron outputs simultaneously in experiments using DT/TT fusion ratio as a direct measure of mix of ablator into the gas.
Performance Enhancement of a High Speed Jet Impingement System for Nonvolatile Residue Removal
NASA Technical Reports Server (NTRS)
Klausner, James F.; Mei, Renwei; Near, Steve; Stith, Rex
1996-01-01
A high speed jet impingement cleaning facility has been developed to study the effectiveness of the nonvolatile residue removal. The facility includes a high pressure air compressor which charges the k-bottles to supply high pressure air, an air heating section to vary the temperature of the high pressure air, an air-water mixing chamber to meter the water flow and generate small size droplets, and a converging- diverging nozzle to deliver the supersonic air-droplet mixture flow to the cleaning surface. To reliably quantify the cleanliness of the surface, a simple procedure for measurement and calibration is developed to relate the amount of the residue on the surface to the relative change in the reflectivity between a clean surface and the greased surface. This calibration procedure is economical, simple, reliable, and robust. a theoretical framework is developed to provide qualitative guidance for the design of the test and interpretation of the experimental results. The result documented in this report support the theoretical considerations.
Yeamans, C B; Gharibyan, N
2016-11-01
At the National Ignition Facility, the diagnostic instrument manipulator-based neutron activation spectrometer is used as a diagnostic of implosion performance for inertial confinement fusion experiments. Additionally, it serves as a platform for independent neutronic experiments and may be connected to fast recording systems for neutron effect tests on active electronics. As an implosion diagnostic, the neutron activation spectrometers are used to quantify fluence of primary DT neutrons, downscattered neutrons, and neutrons above the primary DT neutron energy created by reactions of upscattered D and T in flight. At a primary neutron yield of 10 15 and a downscattered fraction of neutrons in the 10-12 MeV energy range of 0.04, the downscattered neutron fraction can be measured to a relative uncertainty of 8%. Significant asymmetries in downscattered neutrons have been observed. Spectrometers have been designed and fielded to measure the tritium-tritium and deuterium-tritium neutron outputs simultaneously in experiments using DT/TT fusion ratio as a direct measure of mix of ablator into the gas.
NASA Astrophysics Data System (ADS)
Chung, Myeong Y.; Beene, Matt; Ashkan, Shawn; Krauter, Charles; Hasson, Alam S.
2010-02-01
Dairies are believed to be a major source of volatile organic compounds (VOC) in Central California, but few studies have characterized VOC emissions from these facilities. In this work, samples were collected from six sources of VOCs (Silage, Total Mixed Rations, Lagoons, Flushing Lanes, Open Lots and Bedding) at six dairies in Central California during 2006-2007 using emission isolation flux chambers and polished stainless steel canisters. Samples were analyzed by gas chromatography/mass spectrometry and gas chromatography/flame ionization detection. Forty-eight VOCs were identified and quantified in the samples, including alcohols, carbonyls, alkanes and aromatics. Silage and Total Mixed Rations are the dominant sources of VOCs tested, with ethanol as the major VOC present. Emissions from the remaining sources are two to three orders of magnitude smaller, with carbonyls and aromatics as the main components. The data suggest that animal feed rather than animal waste are the main source of non-enteric VOC emissions from dairies.
Zakumumpa, Henry; Bennett, Sara; Ssengooba, Freddie
2017-01-23
Sub-Saharan Africa is heavily dependent on global health initiatives (GHIs) for funding antiretroviral therapy (ART) scale-up. There are indications that global investments for ART scale-up are flattening. It is unclear what new funding channels can bridge the funding gap for ART service delivery. Many previous studies have focused on domestic government spending and international funding especially from GHIs. The objective of this study was to identify the funding strategies adopted by health facilities in Uganda to sustain ART programs between 2004 and 2014 and to explore variations in financing mechanisms by ownership of health facility. A mixed-methods approach was employed. A survey of health facilities (N = 195) across Uganda which commenced ART delivery between 2004 and 2009 was conducted. Six health facilities were purposively selected for in-depth examination. Semi-structured interviews (N = 18) were conducted with ART Clinic managers (three from each of the six health facilities). Statistical analyses were performed in STATA (Version 12.0) and qualitative data were analyzed by coding and thematic analysis. Multiple funding sources for ART programs were common with 140 (72%) of the health facilities indicating at least two concurrent grants supporting ART service delivery between 2009 and 2014. Private philanthropic aid emerged as an important source of supplemental funding for ART service delivery. ART financing strategies were differentiated by ownership of health facility. Private not-for-profit providers were more externally-focused (multiple grants, philanthropic aid). For-profit providers were more client-oriented (fee-for-service, insurance schemes). Public facilities sought additional funding streams not dissimilar to other health facility ownership-types. Over the 10-year study period, health facilities in Uganda diversified funding sources for ART service delivery. The identified alternative funding mechanisms could reduce dependence on GHI funding and increase local ownership of HIV programs. Further research evaluating the potential contribution of the identified alternative financing mechanisms in bridging the global HIV funding gap is recommended.
Cost analysis and facility reimbursement in the long-term health care industry.
Ullmann, S G
1984-01-01
This article examines costs and develops a system of prospective reimbursement for the industry committed to long-term health care. Together with estimates of average cost functions--for purposes of determining those factors affecting the costs of long-term health care, the author examines in depth the cost effects of patient mix and facility quality. Policy implications are indicated. The article estimates cost savings and predicted improvements in facility performance resulting from adoption of a prospective reimbursement system. PMID:6427138
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beauchesne, A.M.
1997-12-31
Topics explored through this project include: decisions involving disposal of mixed, low-level, and transuranic (TRU) waste and disposition of nuclear materials; decisions involving DOE budget requests and their effect on environmental cleanup and compliance at DOE facilities; strategies to treat mixed, low-level, and transuranic (TRU) waste and their effect on individual sites in the complex; changes to the FFCA site treatment plans as a result of proposals in the EM 2006 cleanup plans and contractor integration analysis; interstate waste and materials shipments; and reforms to existing RCRA and CERCLA regulations/guidance to address regulatory overlap and risks posed by DOE wastes.more » The work accomplished by the NGA project team during the past four months can be categorized as follows: maintained open communication with DOE on a variety of activities and issues within the DOE environmental management complex; and maintained communication with NGA Federal Facilities Compliance Task Force members regarding DOE efforts to formulate a configuration for mixed low-level waste and low-level treatment and disposal, DOE activities in the area of the Hazardous Waste Identification Rule, and DOE`s proposed National Dialogue.« less
EPR/PTFE dosimetry for test reactor environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vehar, D.W.; Griffin, P.J.; Quirk, T.J.
2011-07-01
The use of Electron Paramagnetic Resonance (EPR) spectroscopy with materials such as alanine is well established as a technique for measurement of ionizing radiation absorbed dose in photon and electron fields such as Co-60, high-energy bremsstrahlung and electron-beam fields [1]. In fact, EPR/Alanine dosimetry has become a routine transfer standard for national standards bodies such as NIST and NPL. In 1992 the Radiation Metrology Laboratory (RML) at Sandia National Laboratories implemented EPR/Alanine capabilities for use in routine and calibration activities at its Co-60 and pulsed-power facilities. At that time it also investigated the usefulness of the system for measurement ofmore » absorbed dose in the mixed neutron/photon environments of reactors such as the Sandia Pulsed Reactor and the Annular Core Research Reactor used for hardness testing of electronics. The RML concluded that the neutron response of alanine was a sufficiently high fraction of the overall dosimeter response that the resulting uncertainties in the photon dose would be unacceptably large for silicon-device testing. However, it also suggested that non-hydrogenous materials such as polytetrafluoroethylene (PTFE) would exhibit smaller neutron response and might be useful in mixed environments. Preliminary research with PTFE in photon environments indicated considerable promise, but further development was not pursued at that time. Because of renewed interest in absorbed dose measurements that could better define the individual contributions of photon and neutron components to the overall dose delivered to a test object, the RML has re-initiated the development of an EPR/PTFE dosimetry system. This effort consists of three stages: 1) Identification of PTFE materials that may be suitable for dosimetry applications. It was speculated that the inconsistency of EPR signatures in the earlier samples may have been due to variability in PTFE manufacturing processes. 2) Characterization of dosimetry in photon-only environments. This is necessary to establish requirements for sample preparation, operating parameters and limitations for use in well-defined and predictable environments prior to deployment in the less well-defined mixed environments of test reactors. 3) Characterization of the EPR responses obtained with PTFE in mixed neutron/photon fields. This includes evaluation of the neutron and photon contributions to response, determination of applicable of neutron fluence and photon dose ranges. This paper presents a summary of the research, a description of the EPR/PTFE dosimetry system, and recommendations for preparation and fielding of the dosimetry in photon and mixed neutron/photon environments. (authors)« less
Does investor ownership of nursing homes compromise the quality of care?
Harrington, C; Woolhandler, S; Mullan, J; Carrillo, H; Himmelstein, D U
2001-09-01
Two thirds of nursing homes are investor owned. This study examined whether investor ownership affects quality. We analyzed 1998 data from state inspections of 13,693 nursing facilities. We used a multivariate model and controlled for case mix, facility characteristics, and location. Investor-owned facilities averaged 5.89 deficiencies per home, 46.5% higher than nonprofit facilities and 43.0% higher than public facilities. In multivariate analysis, investor ownership predicted 0.679 additional deficiencies per home; chain ownership predicted an additional 0.633 deficiencies. Nurse staffing was lower at investor-owned nursing homes. Investor-owned nursing homes provide worse care and less nursing care than do not-for-profit or public homes.
Hot-spot mix in ignition-scale inertial confinement fusion targets.
Regan, S P; Epstein, R; Hammel, B A; Suter, L J; Scott, H A; Barrios, M A; Bradley, D K; Callahan, D A; Cerjan, C; Collins, G W; Dixit, S N; Döppner, T; Edwards, M J; Farley, D R; Fournier, K B; Glenn, S; Glenzer, S H; Golovkin, I E; Haan, S W; Hamza, A; Hicks, D G; Izumi, N; Jones, O S; Kilkenny, J D; Kline, J L; Kyrala, G A; Landen, O L; Ma, T; MacFarlane, J J; MacKinnon, A J; Mancini, R C; McCrory, R L; Meezan, N B; Meyerhofer, D D; Nikroo, A; Park, H-S; Ralph, J; Remington, B A; Sangster, T C; Smalyuk, V A; Springer, P T; Town, R P J
2013-07-26
Mixing of plastic ablator material, doped with Cu and Ge dopants, deep into the hot spot of ignition-scale inertial confinement fusion implosions by hydrodynamic instabilities is diagnosed with x-ray spectroscopy on the National Ignition Facility. The amount of hot-spot mix mass is determined from the absolute brightness of the emergent Cu and Ge K-shell emission. The Cu and Ge dopants placed at different radial locations in the plastic ablator show the ablation-front hydrodynamic instability is primarily responsible for hot-spot mix. Low neutron yields and hot-spot mix mass between 34(-13,+50) ng and 4000(-2970,+17 160) ng are observed.
Hot-spot mix in ignition-scale inertial confinement fusion targets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Regan, S. P.; Epstein, R.; Hammel, B. A.
Mixing of plastic ablator material, doped with Cu and Ge dopants, deep into the hot spot of ignition-scale inertial confinement fusion implosions by hydrodynamic instabilities is diagnosed with x-ray spectroscopy on the National Ignition Facility. The amount of hot-spot mix mass is determined from the absolute brightness of the emergent Cu and Ge K-shell emission. The Cu and Ge dopants placed at different radial locations in the plastic ablator show the ablation-front hydrodynamic instability is primarily responsible for hot-spot mix. As a result, low neutron yields and hot-spot mix mass between 34(–13,+50) ng and 4000(–2970,+17 160) ng are observed.
Hot-spot mix in ignition-scale inertial confinement fusion targets
Regan, S. P.; Epstein, R.; Hammel, B. A.; ...
2013-07-22
Mixing of plastic ablator material, doped with Cu and Ge dopants, deep into the hot spot of ignition-scale inertial confinement fusion implosions by hydrodynamic instabilities is diagnosed with x-ray spectroscopy on the National Ignition Facility. The amount of hot-spot mix mass is determined from the absolute brightness of the emergent Cu and Ge K-shell emission. The Cu and Ge dopants placed at different radial locations in the plastic ablator show the ablation-front hydrodynamic instability is primarily responsible for hot-spot mix. As a result, low neutron yields and hot-spot mix mass between 34(–13,+50) ng and 4000(–2970,+17 160) ng are observed.
NASA Technical Reports Server (NTRS)
Scully, Robert C.
2011-01-01
Test process, milestones and inputs are unknowns to first-time users of the EMI/EMC Test Facility. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.
Overview of the Orion Vibroacoustic Test Capability at NASA Glenn Research Center
NASA Technical Reports Server (NTRS)
Hughes, William O.; Hozman, Aron D.; McNelis, Mark E.; Otten, Kim D.
2008-01-01
In order to support the environmental test needs for our new Orion and Constellation program, NASA is developing unique world-class test facilities. To optimize this testing of spaceflight hardware while minimizing transportation issues, a one-stop, under one roof test capability is being developed at the Space Power Facility at the NASA Glenn Research Center's Plum Brook Station. This facility will provide the capability to perform the following environmental testing: (1) reverberation acoustic testing, (2) mechanical base-shake sine testing, (3) modal testing, (4) thermal-vacuum testing, and (5) EMI/EMC (electromagnetic interference and compatibility) testing. An overview of this test capability will be provided in this presentation, with special focus on the two new vibroacoustic test facilities currently being designed and built, the Reverberant Acoustic Test Facility (RATF) and the Mechanical Vibration Facility (MVF). Testing of the engineering developmental hardware and qualification hardware of the Orion (Crew Exploration Vehicle) will commence shortly after the facilities are commissioned.
Teno, Joan M; Gozalo, Pedro; Mitchell, Susan L; Bynum, Julie P W; Dosa, David; Mor, Vincent
2011-06-01
Terminal hospitalizations are costly and often avoidable with appropriate advance care planning. This study examined the association between advance care planning, as measured by facility rate of do not resuscitate (DNR) orders in U.S. nursing homes (NHs) and changes in terminal hospitalization rates. Retrospective cohort study of the changing prevalence of DNR orders in U.S. NHs. Using a fixed effect multivariate model, we examined whether increasing facility rate of DNR orders correlates with reductions in terminal hospitalizations in the last week of life, controlling for changes in facility characteristics (staffing, use of NP/PA, case mix of nursing residents, admission volume, racial composition, payer mix). The average facility rate of terminal hospitalizations was 15.5%, fluctuating between 1999 (15.0%) and 2007 (14.8%). NHs starting with low rates of DNR orders that increased their rates had fewer terminal hospital admissions in 2007 (11.2%) than facilities with continuously low DNR usage. Even after applying a multivariate fixed effect model, the effect of changes in facility DNR order rate on terminal hospitalization was -0.056 (95% confidence interval: -0.061, -0.050), indicating that for every 10% increase in DNR orders there was 0.56% decrease in terminal hospitalizations. This rate can be compared with the increase of 0.70% in the terminal hospitalization rate when an NH became disproportionately dependent on Medicaid funding or the 0.40% decrease in terminal hospitalization rate associated with adding a nurse practitioner to the clinical staff complement. NHs that changed their culture of decision making by increasing their facility rate of DNR orders decreased their rate of terminal hospitalizations. Copyright © 2011 U.S. Cancer Pain Relief Committee. Published by Elsevier Inc. All rights reserved.
A survey to assess the extent of public-private mix DOTS in the management of tuberculosis in Zambia
Kapata, Nathan; Maboshe, Mwendaweli; Michelo, Charles; Babaniyi, Olusegun
2015-01-01
Background Involving all relevant healthcare providers in tuberculosis (TB) management through public-private mix (PPM) approaches is a vital element in the World Health Organization's (WHO) Stop TB Strategy. The control of TB in Zambia is mainly done in the public health sector, despite the high overall incidence rates. Aim We conducted a survey to determine the extent of private-sector capacity, participation, practices and adherence to national guidelines in the control of TB. Setting This survey was done in the year 2012 in 157 facilities in three provinces of Zambia where approximately 85% of the country's private health facilities are found. Methods We used a structured questionnaire to interview the heads of private health facilities to assess the participation of the private health sector in TB diagnosis, management and prevention activities. Results Out of 157 facilities surveyed, 40.5% were from the Copperbelt, 4.4% from Central province and 55.1% from Lusaka province. Only 23.8% of the facilities were able to provide full diagnosis and management of TB patients. Although 47.4% of the facilities reported that they do notify their cases to the National TB control programme, the majority (62.7%) of these facilities did not show evidence of notifications. Conclusion Our results show that the majority of the facilities that diagnose and manage TB in the private sector do not report their TB activities to the National TB Control Programme (NTP). There is a need for the NTP to improve collaboration with the private sector with respect to TB control activities and PPM for Directly Observed Treatment, Short Course (DOTS). PMID:26245591
Effects of wind-energy facilities on grassland bird distributions
Shaffer, Jill A.; Buhl, Deb
2016-01-01
The contribution of renewable energy to meet worldwide demand continues to grow. Wind energy is one of the fastest growing renewable sectors, but new wind facilities are often placed in prime wildlife habitat. Long-term studies that incorporate a rigorous statistical design to evaluate the effects of wind facilities on wildlife are rare. We conducted a before-after-control-impact (BACI) assessment to determine if wind facilities placed in native mixed-grass prairies displaced breeding grassland birds. During 2003–2012, we monitored changes in bird density in 3 study areas in North Dakota and South Dakota (U.S.A.). We examined whether displacement or attraction occurred 1 year after construction (immediate effect) and the average displacement or attraction 2–5 years after construction (delayed effect). We tested for these effects overall and within distance bands of 100, 200, 300, and >300 m from turbines. We observed displacement for 7 of 9 species. One species was unaffected by wind facilities and one species exhibited attraction. Displacement and attraction generally occurred within 100 m and often extended up to 300 m. In a few instances, displacement extended beyond 300 m. Displacement and attraction occurred 1 year after construction and persisted at least 5 years. Our research provides a framework for applying a BACI design to displacement studies and highlights the erroneous conclusions that can be made without the benefit of adopting such a design. More broadly, species-specific behaviors can be used to inform management decisions about turbine placement and the potential impact to individual species. Additionally, the avoidance distance metrics we estimated can facilitate future development of models evaluating impacts of wind facilities under differing land-use scenarios.
Effects of wind-energy facilities on breeding grassland bird distributions.
Shaffer, Jill A; Buhl, Deborah A
2016-02-01
The contribution of renewable energy to meet worldwide demand continues to grow. Wind energy is one of the fastest growing renewable sectors, but new wind facilities are often placed in prime wildlife habitat. Long-term studies that incorporate a rigorous statistical design to evaluate the effects of wind facilities on wildlife are rare. We conducted a before-after-control-impact (BACI) assessment to determine if wind facilities placed in native mixed-grass prairies displaced breeding grassland birds. During 2003-2012, we monitored changes in bird density in 3 study areas in North Dakota and South Dakota (U.S.A.). We examined whether displacement or attraction occurred 1 year after construction (immediate effect) and the average displacement or attraction 2-5 years after construction (delayed effect). We tested for these effects overall and within distance bands of 100, 200, 300, and >300 m from turbines. We observed displacement for 7 of 9 species. One species was unaffected by wind facilities and one species exhibited attraction. Displacement and attraction generally occurred within 100 m and often extended up to 300 m. In a few instances, displacement extended beyond 300 m. Displacement and attraction occurred 1 year after construction and persisted at least 5 years. Our research provides a framework for applying a BACI design to displacement studies and highlights the erroneous conclusions that can be made without the benefit of adopting such a design. More broadly, species-specific behaviors can be used to inform management decisions about turbine placement and the potential impact to individual species. Additionally, the avoidance distance metrics we estimated can facilitate future development of models evaluating impacts of wind facilities under differing land-use scenarios. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.
Survey of solar thermal test facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Masterson, K.
The facilities that are presently available for testing solar thermal energy collection and conversion systems are briefly described. Facilities that are known to meet ASHRAE standard 93-77 for testing flat-plate collectors are listed. The DOE programs and test needs for distributed concentrating collectors are identified. Existing and planned facilities that meet these needs are described and continued support for most of them is recommended. The needs and facilities that are suitable for testing components of central receiver systems, several of which are located overseas, are identified. The central contact point for obtaining additional details and test procedures for these facilitiesmore » is the Solar Thermal Test Facilities Users' Association in Albuquerque, N.M. The appendices contain data sheets and tables which give additional details on the technical capabilities of each facility. Also included is the 1975 Aerospace Corporation report on test facilities that is frequently referenced in the present work.« less
Flippo, K. A.; Doss, F. W.; Kline, J. L.; ...
2016-11-23
While using a large volume high-energy-density fluid shear experiment ( 8.5 cm 3 ) at the National Ignition Facility, we have demonstrated for the first time the ability to significantly alter the evolution of a supersonic sheared mixing layer by controlling the initial conditions of that layer. Furthermore, by altering the initial surface roughness of the tracer foil, we demonstrate the ability to transition the shear mixing layer from a highly ordered system of coherent structures to a randomly ordered system with a faster growing mix layer, indicative of strong mixing in the layer at a temperature of severalmore » tens of electron volts and at near solid density. Moreover, simulations using a turbulent-mix model show good agreement with the experimental results and poor agreement without turbulent mix.« less
Awoke, Mamaru Ayenew; Negin, Joel; Moller, Jette; Farell, Penny; Yawson, Alfred E.; Biritwum, Richard Berko; Kowal, Paul
2017-01-01
ABSTRACT Background: Previous studies investigating factors associated with healthcare utilization by older Ghanaians lack distinction between public and private health services. The present study examined factors associated with public and private healthcare service use, and the resulting perceived health system responsiveness. Objectives: To identify factors associated with public and private healthcare utilization among older adults aged 50 and older in Ghana; and to compare perceived differences in health system responsiveness between the private and public sectors. Methods: Cross-sectional data was analyzed from the World Health Organization Study on global AGEing and adult health (SAGE) Wave 1 in Ghana. Using Andersen’s conceptual framework, public and private outpatient care utilization was examined using multinomial logistic regression to estimate and identify predictor variables associated with the type of outpatient healthcare facility accessed. Health system responsiveness was compared using chi-square tests. Results: Of 2517 respondents who used outpatient care in the 12 months preceding interview, 51.7% of respondents used a public facility, 17.8% a private facility, and 30.5% used other facilities. Older age group, higher education and higher wealth were associated with the use of private outpatient healthcare services. Using public outpatient care facilities was associated with having health insurance. Respondents with two or more chronic conditions were more likely to use public and private outpatient care than other facilities. Perceived health system responsiveness was better in private for-profit than in public and private not-for-profit healthcare facilities. Conclusions: This study suggested that higher wealth and multimorbidity were significant predictors of public and private outpatient healthcare utilization; however, health insurance was a predictor only for the use of public facilities. Future mixed-method studies could further elucidate factors influencing the choice of public and private outpatient healthcare use. PMID:28578615
New Hampshire binder and mix review.
DOT National Transportation Integrated Search
2012-08-01
This review was initiated to compare relative rut testing and simple performance tests (now known as Asphalt Mix : Performance Tests) for the New Hampshire inch mix with 15% Recycled Asphalt Pavement (RAP). The tested mixes were : made from ...
Activation of the E1 Ultra High Pressure Propulsion Test Facility at Stennis Space Center
NASA Technical Reports Server (NTRS)
Messer, Bradley; Messer, Elisabeth; Sewell, Dale; Sass, Jared; Lott, Jeff; Dutreix, Lionel, III
2001-01-01
After a decade of construction and a year of activation the El Ultra High Pressure Propulsion Test Facility at NASA's Stennis Space Center is fully operational. The El UHP Propulsion Test Facility is a multi-cell, multi-purpose component and engine test facility . The facility is capable of delivering cryogenic propellants at low, high, and ultra high pressures with flow rates ranging from a few pounds per second up to two thousand pounds per second. Facility activation is defined as a series of tasks required to transition between completion of construction and facility operational readiness. Activating the El UHP Propulsion Test Facility involved independent system checkouts, propellant system leak checks, fluid and gas sampling, gaseous system blow downs, pressurization and vent system checkouts, valve stability testing, valve tuning cryogenic cold flows, and functional readiness tests.
Lewis Research Center space station electric power system test facilities
NASA Technical Reports Server (NTRS)
Birchenough, Arthur G.; Martin, Donald F.
1988-01-01
NASA Lewis Research Center facilities were developed to support testing of the Space Station Electric Power System. The capabilities and plans for these facilities are described. The three facilities which are required in the Phase C/D testing, the Power Systems Facility, the Space Power Facility, and the EPS Simulation Lab, are described in detail. The responsibilities of NASA Lewis and outside groups in conducting tests are also discussed.
Academic status does not affect outcome following complex hepato-pancreato-biliary procedures.
Altieri, Maria S; Yang, Jie; Groves, Donald; Yin, Donglei; Cagino, Kristen; Talamini, Mark; Pryor, Aurora
2018-05-01
There is a growing debate regarding outcomes following complex hepato-pancreato-biliary (HPB) procedures. The purpose of our study is to examine if facility type has any impact on complications, readmission rates, emergency department (ED) visit rates, and length of stay (LOS) for patients undergoing HPB surgery. The SPARCS administrative database was used to identify patients undergoing complex HPB procedures between 2012 and 2014 in New York. Univariate generalized linear mixed models were fit to estimate the marginal association between outcomes such as overall/severe complication rates, 30-day and 1-year readmission rates, 30-day and 1-year ED-visit rates, and potential risk factors. Univariate linear mixed models were used to estimate the marginal association between possible risk factors and LOS. Facility type, as well as any variables found to be significant in our univariate analysis (p = 0.05), was further included in the multivariable regression models. There were 4122 complex HPB procedures performed. Academic facilities were more likely to have a higher hospital volume (p < 0001). Surgery at academic facilities were less likely to have coexisting comorbidities; however, they were more likely to have metastatic cancer and/or liver disease (p = 0.0114, < 0. 0001, and = 0.0299, respectively). Postoperatively, patients at non-academic facilities experienced higher overall complication rates, and higher severe complication rates, when compared to those at academic facilities (p < 0.0001 and = 0.0018, respectively). Further analysis via adjustment for possible confounding factors, however, revealed no significant difference in the risk of severe complications between the two facility types. Such adjustment also demonstrated higher 30-day readmission risk in patients who underwent their surgery at an academic facility. No significant difference was found when comparing the outcomes of academic and non-academic facilities, after adjusting for age, gender, race, region, insurance, and hospital volume. Patients from academic facilities were more likely to be readmitted within the first 30-days after surgery.
Nursing Home Levels of Care: Reimbursement of Resident Specific Costs
Willemain, Thomas R.
1980-01-01
The companion paper on nursing home levels of care (Bishop, Plough and Willemain, 1980) recommended a “split-rate” approach to nursing home reimbursement that would distinguish between fixed and variable costs. This paper examines three alternative treatments of the variable cost component of the rate: a two-level system similar to the distinction between skilled and intermediate care facilities, an individualized (“patient-centered”) system, and a system that assigns a single facility-specific rate that depends on the facility's case-mix (“case-mix reimbursement”). The aim is to better understand the theoretical strengths and weaknesses of these three approaches. The comparison of reimbursement alternatives is framed in terms of minimizing reimbursement error, meaning overpayment and underpayment. We develop a conceptual model of reimbursement error that stresses that the features of the reimbursement scheme are only some of the factors contributing to over- and underpayment. The conceptual model is translated into a computer program for quantitative comparison of the alternatives. PMID:10309330
Nursing home levels of care: reimbursement of resident specific costs.
Willemain, T R
1980-01-01
The companion paper on nursing home levels of care (Bishop, Plough and Willemain, 1980) recommended a "split-rate" approach to nursing home reimbursement that would distinguish between fixed and variable costs. This paper examines three alternative treatments of the variable cost component of the rate: a two-level system similar to the distinction between skilled and intermediate care facilities, an individualized ("patient-centered") system, and a system that assigns a single facility-specific rate that depends on the facility's case-mix ("case-mix reimbursement"). The aim is to better understand the theoretical strengths and weaknesses of these three approaches. The comparison of reimbursement alternatives is framed in terms of minimizing reimbursement error, meaning overpayment and underpayment. We develop a conceptual model of reimbursement error that stresses that the features of the reimbursement scheme are only some of the factors contributing to over- and underpayment. The conceptual model is translated into a computer program for quantitative comparison of the alternatives.
Micronized-Coal Burner Facility
NASA Technical Reports Server (NTRS)
Calfo, F. D.; Lupton, M. W.
1986-01-01
Micronized-coal (coal-in-oil mix) burner facility developed to fulfill need to generate erosion/corrosion data on series of superalloy specimens. In order to successfully operate gas turbine using COM, two primary conditions must be met. First, there must be adequate atomization of COM and second, minimization of coking of burner. Meeting these conditions will be achieved only by clean burning and flame stability.
Skilled nursing facilities reform.
1998-06-01
The Medicare prospective payment system for skilled nursing facilities will take effect with cost reporting years beginning on or after July 1, 1998. HCFA is working on the implementation details. While final details are not expected to be published until Summer 1998, the following information has been provided through HCFA and/or the Nursing Home Case-Mix and Quality (NHCMQ) Demonstration project (RUGs-III) procedures.
ERIC Educational Resources Information Center
Stearns, Sally C.; Park, Jeongyoung; Zimmerman, Sheryl; Gruber-Baldini, Ann L.; Konrad, Thomas R.; Sloane, Philip D.
2007-01-01
Purpose: Residential care/assisted living facilities have become an alternative to nursing homes for many individuals, yet little information exists about staffing in these settings and the effect of staffing. This study analyzed the intensity and skill mix of nursing staff using data from a four-state study, and their relationship to outcomes.…
Facile preparation of nanofiller-paper using mixed office paper without deinking
Qianqian Wang; J.Y. Zhu
2015-01-01
Mixed office paper (MOP) pulp without deinking with an ash content of 18.1 ± 1.5% was used as raw material to produce nanofiller-paper. The MOP pulp with filler was mechanically fibrillated using a laboratory stone grinder. Scanning electron microscope imaging revealed that the ground filler particles were wrapped by cellulose nanofibrils (CNFs), which substantially...
Medicaid payment rates, case-mix reimbursement, and nursing home staffing--1996-2004.
Feng, Zhanlian; Grabowski, David C; Intrator, Orna; Zinn, Jacqueline; Mor, Vincent
2008-01-01
We examined the impact of state Medicaid payment rates and case-mix reimbursement on direct care staffing levels in US nursing homes. We used a recent time series of national nursing home data from the Online Survey Certification and Reporting system for 1996-2004, merged with annual state Medicaid payment rates and case-mix reimbursement information. A 5-category response measure of total staffing levels was defined according to expert recommended thresholds, and examined in a multinomial logistic regression model. Facility fixed-effects models were estimated separately for Registered Nurse (RN), Licensed Practical Nurse (LPN), and Certified Nurse Aide (CNA) staffing levels measured as average hours per resident day. Higher Medicaid payment rates were associated with increases in total staffing levels to meet a higher recommended threshold. However, these gains in overall staffing were accompanied by a reduction of RN staffing and an increase in both LPN and CNA staffing levels. Under case-mix reimbursement, the likelihood of nursing homes achieving higher recommended staffing thresholds decreased, as did levels of professional staffing. Independent of the effects of state, market, and facility characteristics, there was a significant downward trend in RN staffing and an upward trend in both LPN and CNA staffing. Although overall staffing may increase in response to more generous Medicaid reimbursement, it may not translate into improvements in the skill mix of staff. Adjusting for reimbursement levels and resident acuity, total staffing has not increased after the implementation of case-mix reimbursement.
Self-similarity in high Atwood number Rayleigh-Taylor experiments
NASA Astrophysics Data System (ADS)
Mikhaeil, Mark; Suchandra, Prasoon; Pathikonda, Gokul; Ranjan, Devesh
2017-11-01
Self-similarity is a critical concept in turbulent and mixing flows. In the Rayleigh-Taylor instability, theory and simulations have shown that the flow exhibits properties of self-similarity as the mixing Reynolds number exceeds 20000 and the flow enters the turbulent regime. Here, we present results from the first large Atwood number (0.7) Rayleigh-Taylor experimental campaign for mixing Reynolds number beyond 20000 in an effort to characterize the self-similar nature of the instability. Experiments are performed in a statistically steady gas tunnel facility, allowing for the evaluation of turbulence statistics. A visualization diagnostic is used to study the evolution of the mixing width as the instability grows. This allows for computation of the instability growth rate. For the first time in such a facility, stereoscopic particle image velocimetry is used to resolve three-component velocity information in a plane. Velocity means, fluctuations, and correlations are considered as well as their appropriate scaling. Probability density functions of velocity fields, energy spectra, and higher-order statistics are also presented. The energy budget of the flow is described, including the ratio of the kinetic energy to the released potential energy. This work was supported by the DOE-NNSA SSAA Grant DE-NA0002922.
Nuclear thermal propulsion test facility requirements and development strategy
NASA Technical Reports Server (NTRS)
Allen, George C.; Warren, John; Clark, J. S.
1991-01-01
The Nuclear Thermal Propulsion (NTP) subpanel of the Space Nuclear Propulsion Test Facilities Panel evaluated facility requirements and strategies for nuclear thermal propulsion systems development. High pressure, solid core concepts were considered as the baseline for the evaluation, with low pressure concepts an alternative. The work of the NTP subpanel revealed that a wealth of facilities already exists to support NTP development, and that only a few new facilities must be constructed. Some modifications to existing facilities will be required. Present funding emphasis should be on long-lead-time items for the major new ground test facility complex and on facilities supporting nuclear fuel development, hot hydrogen flow test facilities, and low power critical facilities.
Effect of Medicaid Payment on Rehabilitation Care for Nursing Home Residents
Wodchis, Walter P.; Hirth, Richard A.; Fries, Brant E.
2007-01-01
There is considerable interest in examining how Medicaid payment affects nursing home care. This study examines the effect of Medicaid payment methods and reimbursement rates on the delivery of rehabilitation therapy to Medicaid nursing home residents in six States from 1992-1995. In States that changed payment from prospective facility-specific to prospective case-mix adjusted payment methods, Medicaid residents received more rehabilitation therapy after the change. While residents in States using case-mix adjusted payment rates for Medicaid payment were more likely to receive rehabilitation than residents in States using prospective facility-specific Medicaid payment, the differences were general and not specific to Medicaid residents. Retrospective payment for Medicaid resident care was associated with greater use of therapy for Medicaid residents. PMID:17645160
Effect of Medicaid payment on rehabilitation care for nursing home residents.
Wodchis, Walter P; Hirth, Richard A; Fries, Brant E
2007-01-01
There is considerable interest in examining how Medicaid payment affects nursing home care. This study examines the effect of Medicaid payment methods and reimbursement rates on the delivery of rehabilitation therapy to Medicaid nursing home residents in six States from 1992-1995. In States that changed payment from prospective facility-specific to prospective case-mix adjusted payment methods, Medicaid residents received more rehabilitation therapy after the change. While residents in States using case-mix adjusted payment rates for Medicaid payment were more likely to receive rehabilitation than residents in States using prospective facility-specific Medicaid payment, the differences were general and not specific to Medicaid residents. Retrospective payment for Medicaid resident care was associated with greater use of therapy for Medicaid residents.
Gage, Barbara; Stineman, Margaret; Deutsch, Anne; Mallinson, Trudy; Heinemann, Allen; Bernard, Shulamit; Constantine, Roberta
2007-12-01
Better measurement of the case-mix complexity of patients receiving rehabilitation services is critical to understanding variations in the outcomes achieved by patients treated in different postacute care (PAC) settings. The Medicare program recognized this issue and is undertaking a major initiative to develop a new patient-assessment instrument that would standardize case-mix measurement in inpatient rehabilitation facilities, long-term care hospitals, skilled nursing facilities, and home health agencies. The new instrument, called the Continuity Assessment Record and Evaluation Tool, builds on the scientific advances in measurement to develop standard measures of medical acuity, functional status, cognitive impairment, and social support related to resource need, outcomes, and continuity of care for use in all PAC settings.
STD testing policies and practices in U.S. city and county jails.
Parece, M S; Herrera, G A; Voigt, R F; Middlekauff, S L; Irwin, K L
1999-09-01
Studies have shown that sexually transmitted disease (STD) rates are high in the incarcerated population. However, little is known about STD testing policies or practices in jails. To assess STD testing policies and practices in jails. The Division of STD Prevention developed and distributed an e-mail survey to 94 counties reporting more than 40 primary and secondary cases in 1996 or having cities with more than 200,000 persons. State and local STD program managers completed the assessment in collaboration with health departments and the main jail facilities in the selected counties. Most facilities (52-77%) had a policy for STD screening based only on symptoms or by arrestee request, and in these facilities, 0.2% to 6% of arrestees were tested. Facilities having a policy of offering routine testing tested only 3% to 45% of arrestees. Large facilities, facilities using public providers, and facilities routinely testing for syphilis using Stat RPR tested significantly more arrestees (P<0.05). Approximately half of the arrestees were released within 48 hours after intake, whereas 45% of facilities did not have STD testing results until after 48 hours. Most facilities had a policy for STD screening based only on symptoms or by arrestee request. Facilities having a policy of routine STD testing are not testing most of the arrestees. There is a small window (<48 hours) for STD testing and treatment before release. Smaller jails and facilities using private providers may need additional resources to increase STD testing levels. Correctional facilities should be considered an important setting for STD public health intervention where routine rapid STD screening and treatment on-site could be implemented.
Nevada National Security Site Environmental Report Summary 2016
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wills, Cathy
This document is a summary of the full 2016 Nevada National Security Site Environmental Report (NNSSER) prepared by the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/ NFO). This summary provides an abbreviated and more readable version of the full NNSSER. NNSA/NFO prepares the NNSSER to provide the public an understanding of the environmental monitoring and compliance activities that are conducted on the Nevada National Security Site (NNSS) to protect the public and the environment from radiation hazards and from potential nonradiological impacts. It is a comprehensive report of environmental activities performed at the NNSS andmore » offsite facilities over the previous calendar year. The NNSS is currently the nation’s unique site for ongoing national security–related missions and high-risk operations. The NNSS is located about 65 miles northwest of Las Vegas. The approximately 1,360-square-mile site is one of the largest restricted access areas in the United States. It is surrounded by federal installations with strictly controlled access as well as by lands that are open to public entry. In 2016, National Security Technologies, LLC (NSTec), was the NNSS Management and Operations Contractor accountable for ensuring work was performed in compliance with environmental regulations. NNSS activities in 2016 continued to be diverse, with the primary goal to ensure that the existing U.S. stockpile of nuclear weapons remains safe and reliable. Other activities included weapons of mass destruction first responder training; the controlled release of hazardous material at the Nonproliferation Test and Evaluation Complex (NPTEC); remediation of legacy contamination sites; characterization of waste destined for the Waste Isolation Pilot Plant in Carlsbad, New Mexico, or the Idaho National Laboratory in Idaho Falls, Idaho; disposal of low-level and mixed low-level radioactive waste; and environmental research. Facilities and centers that support the National Security/Defense mission include the U1a Facility, Big Explosives Experimental Facility (BEEF), Device Assembly Facility (DAF), National Criticality Experiments Research Center (NCERC) located in the DAF, Joint Actinide Shock Physics Experimental Research (JASPER) Facility, Dense Plasma Focus (DPF) Facility located in the Los Alamos Technical Facility (LATF), and the Radiological/ Nuclear Countermeasures Test and Evaluation Complex (RNCTEC). Facilities that support the Environmental Management mission include the Area 5 Radioactive Waste Management Complex (RWMC) and the Area 3 Radioactive Waste Management Site (RWMS), which has been in cold standby since 2006.« less
Computational parametric study of a Richtmyer-Meshkov instability for an inclined interface.
McFarland, Jacob A; Greenough, Jeffrey A; Ranjan, Devesh
2011-08-01
A computational study of the Richtmyer-Meshkov instability for an inclined interface is presented. The study covers experiments to be performed in the Texas A&M University inclined shock tube facility. Incident shock wave Mach numbers from 1.2 to 2.5, inclination angles from 30° to 60°, and gas pair Atwood numbers of ∼0.67 and ∼0.95 are used in this parametric study containing 15 unique combinations of these parameters. Qualitative results are examined through a time series of density plots for multiple combinations of these parameters, and the qualitative effects of each of the parameters are discussed. Pressure, density, and vorticity fields are presented in animations available online to supplement the discussion of the qualitative results. These density plots show the evolution of two main regions in the flow field: a mixing region containing driver and test gas that is dominated by large vortical structures, and a more homogeneous region of unmixed fluid which can separate away from the mixing region in some cases. The interface mixing width is determined for various combinations of the parameters listed at the beginning of the Abstract. A scaling method for the mixing width is proposed using the interface geometry and wave velocities calculated using one-dimensional gas dynamic equations. This model uses the transmitted wave velocity for the characteristic velocity and an initial offset time based on the travel time of strong reflected waves. It is compared to an adapted Richtmyer impulsive model scaling and shown to scale the initial mixing width growth rate more effectively for fixed Atwood number.
Hardware-in-the-Loop Rendezvous Tests of a Novel Actuators Command Concept
NASA Astrophysics Data System (ADS)
Gomes dos Santos, Willer; Marconi Rocco, Evandro; Boge, Toralf; Benninghoff, Heike; Rems, Florian
2016-12-01
Integration, test and validation results, in a real-time environment, of a novel concept for spacecraft control are presented in this paper. The proposed method commands simultaneously a group of actuators optimizing a given set of objective functions based on a multiobjective optimization technique. Since close proximity maneuvers play an important role in orbital servicing missions, the entire GNC system has been integrated and tested at a hardware-in-the-loop (HIL) rendezvous and docking simulator known as European Proximity Operations Simulator (EPOS). During the test campaign at EPOS facility, a visual camera has been used to provide the necessary measurements for calculating the relative position with respect to the target satellite during closed-loop simulations. In addition, two different configurations of spacecraft control have been considered in this paper: a thruster reaction control system and a mixed actuators mode which includes thrusters, reaction wheels, and magnetic torqrods. At EPOS, results of HIL closed-loop tests have demonstrated that a safe and stable rendezvous approach can be achieved with the proposed GNC loop.
NASA Astrophysics Data System (ADS)
Ola, Max; Thomas, Christiane; Hesse, Ullrich
2017-08-01
Compressor performance test procedures are defined by the standard DIN EN 13771, wherein a variety of possible calorimeter and flow rate measurement methods are suggested. One option is the selection of two independent measurement methods. The accuracies of both selected measurement methods are essential. The second option requires only one method. However the measurement accuracy of the used device has to be verified and recalibrated on a regular basis. The compressor performance test facility at the Technische Universitaet Dresden uses a calibrated flow measurement sensor, a hot gas bypass and a mixed flow heat exchanger. The test bench can easily be modified for tests of various compressor types at different operating ranges and with various refrigerants. In addition, the modified test setup enables the investigation of long term liquid slug and its effects on the compressor. The modification comprises observational components, adjustments of the control system, safety measures and a customized oil recirculation system for compressors which do not contain an integrated oil sump or oil level regulation system. This paper describes the setup of the test bench, its functional principle, the key modifications, first test results and an evaluation of the energy balance.
Boudreau, Michelle Anne; Jensen, Jan L; Edgecombe, Nancy; Clarke, Barry; Burge, Frederick; Archibald, Greg; Taylor, Anthony; Andrew, Melissa K
2013-01-01
Background Prior to the implementation of a new model of care in long-term care facilities in the Capital District Health Authority, Halifax, Nova Scotia, residents entering long-term care were responsible for finding their own family physician. As a result, care was provided by many family physicians responsible for a few residents leading to care coordination and continuity challenges. In 2009, Capital District Health Authority (CDHA) implemented a new model of long-term care called “Care by Design” which includes: a dedicated family physician per floor, 24/7 on-call physician coverage, implementation of a standardized geriatric assessment tool, and an interdisciplinary team approach to care. In addition, a new Emergency Health Services program was implemented shortly after, in which specially trained paramedics dedicated to long-term care responses are able to address urgent care needs. These changes were implemented to improve primary and emergency care for vulnerable residents. Here we describe a comprehensive mixed methods research study designed to assess the impact of these programs on care delivery and resident outcomes. The results of this research will be important to guide primary care policy for long-term care. Objective We aim to evaluate the impact of introducing a new model of a dedicated primary care physician and team approach to long-term care facilities in the CDHA using a mixed methods approach. As a mixed methods study, the quantitative and qualitative data findings will inform each other. Quantitatively we will measure a number of indicators of care in CDHA long-term care facilities pre and post-implementation of the new model. In the qualitative phase of the study we will explore the experience under the new model from the perspectives of stakeholders including family doctors, nurses, administration and staff as well as residents and family members. The proposed mixed method study seeks to evaluate and make policy recommendations related to primary care in long-term care facilities with a focus on end-of-life care and dementia. Methods This is a mixed methods study with concurrent quantitative and qualitative phases. In the quantitative phase, a retrospective time series study is being conducted. Planned analyses will measure indicators of clinical, system, and health outcomes across three time periods and assess the effect of Care by Design as a whole and its component parts. The qualitative methods explore the experiences of stakeholders (ie, physicians, nurses, paramedics, care assistants, administrators, residents, and family members) through focus groups and in depth individual interviews. Results Data collection will be completed in fall 2013. Conclusions This study will generate a considerable amount of outcome data with applications for care providers, health care systems, and applications for program evaluation and quality improvement. Using the mixed methods design, this study will provide important results for stakeholders, as well as other health systems considering similar programs. In addition, this study will advance methods used to research new multifaceted interdisciplinary health delivery models using multiple and varied data sources and contribute to the discussion on evidence based health policy and program development. PMID:24292200
Marshall, Emily Gard; Boudreau, Michelle Anne; Jensen, Jan L; Edgecombe, Nancy; Clarke, Barry; Burge, Frederick; Archibald, Greg; Taylor, Anthony; Andrew, Melissa K
2013-11-29
Prior to the implementation of a new model of care in long-term care facilities in the Capital District Health Authority, Halifax, Nova Scotia, residents entering long-term care were responsible for finding their own family physician. As a result, care was provided by many family physicians responsible for a few residents leading to care coordination and continuity challenges. In 2009, Capital District Health Authority (CDHA) implemented a new model of long-term care called "Care by Design" which includes: a dedicated family physician per floor, 24/7 on-call physician coverage, implementation of a standardized geriatric assessment tool, and an interdisciplinary team approach to care. In addition, a new Emergency Health Services program was implemented shortly after, in which specially trained paramedics dedicated to long-term care responses are able to address urgent care needs. These changes were implemented to improve primary and emergency care for vulnerable residents. Here we describe a comprehensive mixed methods research study designed to assess the impact of these programs on care delivery and resident outcomes. The results of this research will be important to guide primary care policy for long-term care. We aim to evaluate the impact of introducing a new model of a dedicated primary care physician and team approach to long-term care facilities in the CDHA using a mixed methods approach. As a mixed methods study, the quantitative and qualitative data findings will inform each other. Quantitatively we will measure a number of indicators of care in CDHA long-term care facilities pre and post-implementation of the new model. In the qualitative phase of the study we will explore the experience under the new model from the perspectives of stakeholders including family doctors, nurses, administration and staff as well as residents and family members. The proposed mixed method study seeks to evaluate and make policy recommendations related to primary care in long-term care facilities with a focus on end-of-life care and dementia. This is a mixed methods study with concurrent quantitative and qualitative phases. In the quantitative phase, a retrospective time series study is being conducted. Planned analyses will measure indicators of clinical, system, and health outcomes across three time periods and assess the effect of Care by Design as a whole and its component parts. The qualitative methods explore the experiences of stakeholders (ie, physicians, nurses, paramedics, care assistants, administrators, residents, and family members) through focus groups and in depth individual interviews. Data collection will be completed in fall 2013. This study will generate a considerable amount of outcome data with applications for care providers, health care systems, and applications for program evaluation and quality improvement. Using the mixed methods design, this study will provide important results for stakeholders, as well as other health systems considering similar programs. In addition, this study will advance methods used to research new multifaceted interdisciplinary health delivery models using multiple and varied data sources and contribute to the discussion on evidence based health policy and program development.
Wake Shield Facility Modal Survey Test in Vibration Acoustic Test Facility
1991-10-09
Astronaut Ronald M. Sega stands beside the University of Houston's Wake Shield Facility before it undergoes a Modal Survey Test in the Vibration and Acoustic Test Facility Building 49, prior to being flown on space shuttle mission STS-60.
Casey, R; Chaix, B; Weber, C; Schweitzer, B; Charreire, H; Salze, P; Badariotti, D; Banos, A; Oppert, J-M; Simon, C
2012-01-01
Objective: Some characteristics of the built environment have been associated with obesity in youth. Our aim was to determine whether individual and environmental socio-economic characteristics modulate the relation between youth overweight and spatial accessibility to physical activity (PA) facilities and to food outlets. Design: Cross-sectional study. Subjects: 3293 students, aged 12±0.6 years, randomly selected from eastern France middle schools. Measurements and methods: Using geographical information systems (GIS), spatial accessibility to PA facilities (urban and nature) was assessed using the distance to PA facilities at the municipality level; spatial accessibility to food outlets (general food outlets, bakeries and fast-food outlets) was calculated at individual level using the student home address and the food outlets addresses. Relations of weight status with spatial accessibility to PA facilities and to food outlets were analysed using mixed logistic models, testing potential direct and interaction effects of individual and environmental socio-economic characteristics. Results: Individual socio-economic status modulated the relation between spatial accessibility to PA facilities and to general food outlets and overweight. The likelihood of being overweight was higher when spatial accessibility to urban PA facilities and to general food outlets was low, but in children of blue-collar-workers only. The odds ratio (OR) (95% confidence interval) for being overweight of blue-collar-workers children compared with non-blue-collar-workers children was 1.76 (1.25–2.49) when spatial accessibility to urban PA facilities was low. This OR was 1.86 (1.20–2.86) when spatial accessibility to general food outlets was low. There was no significant relationship of overweight with either nature PA facilities or other food outlets (bakeries and fast-food outlets). Conclusion: These results indicate that disparities in spatial accessibility to PA facilities and to general food outlets may amplify the risk of overweight in socio-economically disadvantaged youth. These data should be relevant for influencing health policies and urban planning at both a national and local level. PMID:22310474
Survey of aircraft icing simulation test facilities in North America
NASA Technical Reports Server (NTRS)
Olsen, W.
1981-01-01
A survey was made of the aircraft icing simulation facilities in North America: there are 12 wind tunnels, 28 engine test facilities, 6 aircraft tankers and 14 low velocity facilities, that perform aircraft icing tests full or part time. The location and size of the facility, its speed and temperature range, icing cloud parameters, and the technical person to contact are surveyed. Results are presented in tabular form. The capabilities of each facility were estimated by its technical contact person. The adequacy of these facilities for various types of icing tests is discussed.
VIEW LOOKING SOUTH AT THE SATURN V (BLDG. 4550) AND ...
VIEW LOOKING SOUTH AT THE SATURN V (BLDG. 4550) AND SATURN I (BLDG. 4557) STRUCTURAL TEST FACILITIES, SATURN V TEST FACILITY IS IN THE FOREGROUND RIGHT. THE SATURN I TEST FACILITY IS IN THE BACKGROUND CENTER. - Marshall Space Flight Center, Saturn V Dynamic Test Facility, East Test Area, Huntsville, Madison County, AL
Does Investor Ownership of Nursing Homes Compromise the Quality of Care?
Harrington, Charlene; Woolhandler, Steffie; Mullan, Joseph; Carrillo, Helen; Himmelstein, David U.
2001-01-01
Objectives. Two thirds of nursing homes are investor owned. This study examined whether investor ownership affects quality. Methods. We analyzed 1998 data from state inspections of 13 693 nursing facilities. We used a multivariate model and controlled for case mix, facility characteristics, and location. Results. Investor-owned facilities averaged 5.89 deficiencies per home, 46.5% higher than nonprofit facilities and 43.0% higher than public facilities. In multivariate analysis, investor ownership predicted 0.679 additional deficiencies per home; chain ownership predicted an additional 0.633 deficiencies. Nurse staffing was lower at investor-owned nursing homes. Conclusions. Investor-owned nursing homes provide worse care and less nursing care than do not-for-profit or public homes. PMID:11527781
Effect of academic status on outcomes of surgery for rectal cancer.
Cagino, Kristen; Altieri, Maria S; Yang, Jie; Nie, Lizhou; Talamini, Mark; Spaniolas, Konstantinos; Denoya, Paula; Pryor, Aurora
2018-06-01
The purpose of our study was to investigate surgical outcomes following advanced colorectal procedures at academic versus community institutions. The SPARCS database was used to identify patients undergoing Abdominoperineal resection (APR) and Low Anterior Resection between 2009 and 2014. Linear mixed models and generalized linear mixed models were used to compare outcomes. Laparoscopic versus open procedures, surgery type, volume status, and stoma formation between academic and community facilities were compared. Higher percentages of laparoscopic surgeries (58.68 vs. 41.32%, p value < 0.0001), more APR surgeries (64.60 vs. 35.40%, p value < 0.0001), more high volume hospitals (69.46 vs. 30.54%, p value < 0.0001), and less stoma formation (48.00 vs. 52.00%, p value < 0.0001) were associated with academic centers. After adjusting for confounding factors, academic facilities were more likely to perform APR surgeries (OR 1.35, 95% CI 1.04-1.74, p value = 0.0235). Minorities and Medicaid patients were more likely to receive care at an academic facility. Stoma formation, open surgery, and APR were associated with longer LOS and higher rate of ED visit and 30-day readmission. Laparoscopy and APR are more commonly performed at academic than community facilities. Age, sex, race, and socioeconomic status affect the facility at which and the type of surgery patients receive, thereby influencing surgical outcomes.
NASA Technical Reports Server (NTRS)
Crouch, R. K.; Fripp, A. L.; Debnam, W. J.; Clark, I. O.
1983-01-01
The MEA-2 A facility was used to test the effect of the low gravity environment on suppressing convective mixing in the growth of Pb(1-x)Sn(x)Te crystals. The need to eliminate convection, the furnace characteristics and operation that will be required for successful experimental implementation, and to the level that is presently known, the measured physical properties of the Pb(1-x)Sn(x)Te system were discussed. In addition, a brief background of the present and potential utilization of Pb(1-x)Sn(x)Te is given. Additional experiments are anticipated in future MEA-A, improved MEA and other dedicated materials processing in space flight apparatus.
Valentin, Francisco I.; Artoun, Narbeh; Anderson, Ryan; ...
2016-12-01
Very High Temperature Reactors (VHTRs) are one of the Generation IV gas-cooled reactor models proposed for implementation in next generation nuclear power plants. A high temperature/pressure test facility for forced and natural circulation experiments has been constructed. This test facility consists of a single flow channel in a 2.7 m (9’) long graphite column equipped with four 2.3kW heaters. Extensive 3D numerical modeling provides a detailed analysis of the thermal-hydraulic behavior under steady-state, transient, and accident scenarios. In addition, forced/mixed convection experiments with air, nitrogen and helium were conducted for inlet Reynolds numbers from 500 to 70,000. Our numerical resultsmore » were validated with forced convection data displaying maximum percentage errors under 15%, using commercial finite element package, COMSOL Multiphysics. Based on this agreement, important information can be extracted from the model, with regards to the modified radial velocity and property gas profiles. Our work also examines flow laminarization for a full range of Reynolds numbers including laminar, transition and turbulent flow under forced convection and its impact on heat transfer under various scenarios to examine the thermal-hydraulic phenomena that could occur during both normal operation and accident conditions.« less
40 CFR 792.31 - Testing facility management.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Testing facility management. 792.31... facility management. For each study, testing facility management shall: (a) Designate a study director as... appropriately tested for identity, strength, purity, stability, and uniformity, as applicable. (e) Assure that...
Facility-level outcome performance measures for nursing homes.
Porell, F; Caro, F G
1998-12-01
Risk-adjusted nursing home performance scores were developed for four health outcomes and five quality indicators from resident-level longitudinal case-mix reimbursement data for Medicaid residents of more than 500 nursing homes in Massachusetts. Facility performance was measured by comparing actual resident outcomes with expected outcomes derived from quarterly predictions of resident-level econometric models over a 3-year period (1991-1994). Performance measures were tightly distributed among facilities in the state. The intercorrelations among the nine outcome performance measures were relatively low and not uniformly positive. Performance measures were not highly associated with various structural facility attributes. For most outcomes, longitudinal analyses revealed only modest correlations between a facility's performance score from one time period to the next. Relatively few facilities exhibited consistent superior or inferior performance over time. The findings have implications toward the practical use of facility outcome performance measures for quality assurance and reimbursement purposes in the near future.
Antenna Test Facility (ATF): User Test Planning Guide
NASA Technical Reports Server (NTRS)
Lin, Greg
2011-01-01
Test process, milestones and inputs are unknowns to first-time users of the ATF. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.
Radiant Heat Test Facility (RHTF): User Test Planning Guide
NASA Technical Reports Server (NTRS)
DelPapa, Steven
2011-01-01
Test process, milestones and inputs are unknowns to first-time users of the RHTF. The User Test Planning Guide aids in establishing expectations for both NASA and non- NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.
NASA Technical Reports Server (NTRS)
Stradling, J.; Pippen, D. L.
1985-01-01
The NASA Johnson Space Center White Sands Test Facility (WSTF) performs aerospace materials testing and evaluation. Established in 1963, the facility grew from a NASA site dedicated to the development of space engines for the Apollo project to a major test facility. In addition to propulsion tests, it tests materials and components, aerospace fluids, and metals and alloys in simulated space environments.
40 CFR 160.31 - Testing facility management.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Testing facility management. 160.31... GOOD LABORATORY PRACTICE STANDARDS Organization and Personnel § 160.31 Testing facility management. For each study, testing facility management shall: (a) Designate a study director as described in § 160.33...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mineo, Hideaki; Matsumura, Tatsuro; Takeshita, Isao
1997-03-01
The Nuclear Fuel Cycle Safety Engineering Research Facility (NUCEF) is a large complex of research facilities where transuranic (TRU) elements are used. Liquid and solid waste containing TRU elements is generated mainly in the treatment of fuel for critical experiments and in the research of reprocessing and TRU waste management in hot cells and glove boxes. The rational management of TRU wastes is a very important issue not only for NUCEF but also for Japan. An integrated TRU waste management system is being developed with NUCEF as the test bed. The basic policy for establishing the system is to classifymore » wastes by TRU concentration, to reduce waste volume, and to maximize reuse of TRU elements. The principal approach of the development program is to apply the outcomes of the research carried out in NUCEF. Key technologies are TRU measurement for classification of solid wastes and TRU separation and volume reduction for organic and aqueous wastes. Some technologies required for treating the wastes specific to the research activities in NUCEF need further development. Specifically, the separation and stabilization technologies for americium recovery from concentrated aqueous waste, which is generated in dissolution of mixed oxide when preparing fuel for critical experiments, needs further research.« less
Bohren, Meghan A.; Vogel, Joshua P.; Hunter, Erin C.; Lutsiv, Olha; Makh, Suprita K.; Souza, João Paulo; Aguiar, Carolina; Saraiva Coneglian, Fernando; Diniz, Alex Luíz Araújo; Tunçalp, Özge; Javadi, Dena; Oladapo, Olufemi T.; Khosla, Rajat; Hindin, Michelle J.; Gülmezoglu, A. Metin
2015-01-01
Background Despite growing recognition of neglectful, abusive, and disrespectful treatment of women during childbirth in health facilities, there is no consensus at a global level on how these occurrences are defined and measured. This mixed-methods systematic review aims to synthesize qualitative and quantitative evidence on the mistreatment of women during childbirth in health facilities to inform the development of an evidence-based typology of the phenomenon. Methods and Findings We searched PubMed, CINAHL, and Embase databases and grey literature using a predetermined search strategy to identify qualitative, quantitative, and mixed-methods studies on the mistreatment of women during childbirth across all geographical and income-level settings. We used a thematic synthesis approach to synthesize the qualitative evidence and assessed the confidence in the qualitative review findings using the CERQual approach. In total, 65 studies were included from 34 countries. Qualitative findings were organized under seven domains: (1) physical abuse, (2) sexual abuse, (3) verbal abuse, (4) stigma and discrimination, (5) failure to meet professional standards of care, (6) poor rapport between women and providers, and (7) health system conditions and constraints. Due to high heterogeneity of the quantitative data, we were unable to conduct a meta-analysis; instead, we present descriptions of study characteristics, outcome measures, and results. Additional themes identified in the quantitative studies are integrated into the typology. Conclusions This systematic review presents a comprehensive, evidence-based typology of the mistreatment of women during childbirth in health facilities, and demonstrates that mistreatment can occur at the level of interaction between the woman and provider, as well as through systemic failures at the health facility and health system levels. We propose this typology be adopted to describe the phenomenon and be used to develop measurement tools and inform future research, programs, and interventions. PMID:26126110
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ann M. Beauchesne
1999-04-30
Through the National Governors' Association (NGA) project ''Critical Issues Related to Radioactive Waste and Materials Disposition Involving DOE Facilities'' NGA brings together Governors' policy advisors, state regulators, and DOE officials to examine critical issues related to the cleanup and operation of DOE nuclear weapons and research facilities. Topics explored through this project include: Decisions involving disposal of mixed, low-level, and transuranic (TRU) waste and disposition of nuclear materials; Decisions involving DOE budget requests and their effect on environmental cleanup and compliance at DOE facilities; Strategies to treat mixed, low-level, and transuranic (TRU) waste and their effect on individual sites inmore » the complex; Changes to the FFCA site treatment plans as a result of proposals in the Department's Accelerating Cleanup: Paths to Closure plan and contractor integration analysis; Interstate waste and materials shipments; and Reforms to existing RCRA and CERCLA regulations/guidance to address regulatory overlap and risks posed by DOE wastes. The overarching theme of this project is to help the Department improve coordination of its major program decisions with Governors' offices and state regulators and to ensure such decisions reflect input from these key state officials and stakeholders. This report summarizes activities conducted during the quarter from February 1, 1999, through April 30, 1999, under the NGA grant. The work accomplished by the NGA project team during the past four months can be categorized as follows: maintained open communication with DOE on a variety of activities and issues within the DOE environmental management complex; maintained communication with NGA Federal Facilities Compliance Task Force members regarding DOE efforts to formulate a configuration for mixed low-level waste and low-level treatment and disposal, external regulation of DOE; and EM Integration activities; and continued to serve as a liaison between the NGA FFCA Task Force states and the Department.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-07-01
Through the National Governors' Association (NGA) project ''Critical Issues Related to Radioactive Waste and Materials Disposition Involving DOE Facilities'' NGA brings together Governors' policy advisors, state regulators, and DOE officials to examine critical issues related to the cleanup and operation of DOE nuclear weapons and research facilities. Topics explored through this project include: Decisions involving disposal of mixed, low-level, and transuranic (TRU) waste and disposition of nuclear materials. Decisions involving DOE budget requests and their effect on environmental cleanup and compliance at DOE facilities. Strategies to treat mixed, low-level, and transuranic (TRU) waste and their effect on individual sites inmore » the complex. Changes to the FFCA site treatment plans as a result of proposals in DOE's Accelerating Cleanup: Paths to Closure strategy and contractor integration analysis. Interstate waste and materials shipments. Reforms to existing RCRA and CERCLA regulations/guidance to address regulatory overlap and risks posed by DOE wastes. The overarching theme of this project is to help the Department improve coordination of its major program decisions with Governors' offices and state regulators and to ensure such decisions reflect input from these key state officials and stakeholders. This report summarizes activities conducted during the quarter from April 30, 1998 through June 30, 1998 under the NGA project. The work accomplished by the NGA project team during the past four months can be categorized as follows: maintained open communication with DOE on a variety of activities and issues within the DOE environmental management complex; and provided ongoing support to state-DOE interactions. maintained communication with NGA Federal Facilities Compliance Task Force members regarding DOE efforts to formulate a configuration for mixed low-level waste and low-level treatment and disposal, DOE's Environmental Management Budget, and DOE's proposed Intersite Discussions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ann B. Beauchesne
1998-09-30
Through the National Governors' Association (NGA) project ''Critical Issues Related to Radioactive Waste and Materials Disposition Involving DOE Facilities'' NGA brings together Governors' policy advisors, state regulators, and DOE officials to examine critical issues related to the cleanup and operation of DOE nuclear weapons and research facilities. Topics explored through this project include: (1) Decisions involving disposal of mixed, low-level, and transuranic (TRU) waste and disposition of nuclear materials; (2) Decisions involving DOE budget requests and their effect on environmental cleanup and compliance at DOE facilities; (3) Strategies to treat mixed, low-level, and transuranic (TRU) waste and their effect onmore » individual sites in the complex; (4) Changes to the FFCA site treatment plans as a result of proposals in the Department's Accelerating Cleanup: Paths to Closure plan and contractor integration analysis; (5) Interstate waste and materials shipments; and (6) Reforms to existing RCRA and CERCLA regulations/guidance to address regulatory overlap and risks posed by DOE wastes. The overarching theme of this project is to help the Department improve coordination of its major program decisions with Governors' offices and state regulators and to ensure such decisions reflect input from these key state officials and stakeholders. This report summarizes activities conducted during the quarter from June 1, 1998 through September 30, 1998, under the NGA grant. The work accomplished by the NGA project team during the past four months can be categorized as follows: (1) maintained open communication with DOE on a variety of activities and issues within the DOE environmental management complex; (2) maintained communication with NGA Federal Facilities Compliance Task Force members regarding DOE efforts to formulate a configuration for mixed low-level waste and low-level treatment and disposal, external regulation of DOE; and EM Integration activities; and (3) continued to serve as a liaison between the NGA FFCA Task Force states and the Department.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ann M. Beauchesne
1999-07-30
Through the National Governors' Association (NGA) project ''Critical Issues Related to Radioactive Waste and Materials Disposition Involving DOE Facilities'' NGA brings together Governors' policy advisors, state regulators, and DOE officials to examine critical issues related to the cleanup and operation of DOE nuclear weapons and research facilities. Topics explored through this project include: Decisions involving disposal of mixed, low-level, and transuranic (TRU) waste and disposition of nuclear materials; Decisions involving DOE budget requests and their effect on environmental cleanup and compliance at DOE facilities; Strategies to treat mixed, low-level, and transuranic (TRU) waste and their effect on individual sites inmore » the complex; Changes to the FFCA site treatment plans as a result of proposals in the Department's Accelerating Cleanup: Paths to Closure plan and contractor integration analysis; Interstate waste and materials shipments; and Reforms to existing RCRA and CERCLA regulations/guidance to address regulatory overlap and risks posed by DOE wastes. The overarching theme of this project is to help the Department improve coordination of its major program decisions with Governors' offices and state regulators and to ensure such decisions reflect input from these key state officials and stakeholders. This report summarizes activities conducted during the quarter from May 1, 1999, through July 30, 1999, under the NGA grant. The work accomplished by the NGA project team during the past four months can be categorized as follows: maintained open communication with DOE on a variety of activities and issues within the DOE environmental management complex; maintained communication with NGA Federal Facilities Compliance Task Force members regarding DOE efforts to formulate a configuration for mixed low-level waste and low-level treatment and disposal, external regulation of DOE; and continued to facilitate interactions between the states and DOE to develop a foundation for an ongoing substantive relationship between the Governors of key states and Secretary Richardson.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ann M. Beauchesne
1999-01-31
Through the National Governors' Association (NGA) project ''Critical Issues Related to Radioactive Waste and Materials Disposition Involving DOE Facilities'' NGA brings together Governors' policy advisors, state regulators, and DOE officials to examine critical issues related to the cleanup and operation of DOE nuclear weapons and research facilities. Topics explored through this project include: (1) Decisions involving disposal of mixed, low-level, and transuranic (TRU) waste and disposition of nuclear materials; (2) Decisions involving DOE budget requests and their effect on environmental cleanup and compliance at DOE facilities; (3) Strategies to treat mixed, low-level, and transuranic (TRU) waste and their effect onmore » individual sites in the complex; (4) Changes to the FFCA site treatment plans as a result of proposals in the Department's Accelerating Cleanup: Paths to Closure plan and contractor integration analysis; (5) Interstate waste and materials shipments; and (6) Reforms to existing RCRA and CERCLA regulations/guidance to address regulatory overlap and risks posed by DOE wastes. The overarching theme of this project is to help the Department improve coordination of its major program decisions with Governors' offices and state regulators and to ensure such decisions reflect input from these key state officials and stakeholders. This report summarizes activities conducted during the quarter from October 1, 1998 through January 31, 1999, under the NGA grant. The work accomplished by the NGA project team during the past four months can be categorized as follows: (1) maintained open communication with DOE on a variety of activities and issues within the DOE environmental management complex; (2) maintained communication with NGA Federal Facilities Compliance Task Force members regarding DOE efforts to formulate a configuration for mixed low-level waste and low-level treatment and disposal, external regulation of DOE; and EM Integration activities; and (3) continued to serve as a liaison between the NGA FFCA Task Force states and the Department.« less
ERIC Educational Resources Information Center
Buchholz, Jesse
2017-01-01
Increasing a correctional offender's mindset, resilience, and self-efficacy can be accomplished through the efficient use of technology within correctional education. Correctional facilities that employ the use of technology have the capacity to provide offenders with a tool that will serve them while they are incarcerated and again when they are…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Halliwell, Stephen
Radioactive waste materials, including Transuranic (TRU) wastes from laboratories have been stored below ground in large containments at a number of sites in the US DOE Complex, and at nuclear sites in Europe. These containments are generally referred to as caissons or shafts. The containments are in a range of sizes and depths below grade. The caissons at the DOE's Hanford site are cylindrical, of the order of 2,500 mm in diameter, 3,050 mm in height and are buried about 6,000 mm below grade. One type of caisson is made out of corrugated pipe, whereas others are made of concretemore » with standard re-bar. However, the larger shafts in the UK are of the order of 4,600 mm in diameter, 53,500 mm deep, and 12,000 below grade. This paper describes the R and D work and testing activities performed to date to evaluate the concept of in-ground size reduction and stabilization of the contents of large containments similar to those at Hanford. In practice, the height of the Test Facility provided for a test cell that was approximately 22' deep. That prevented a 'full scale mockup' test in the sense that the Hanford Caisson configuration would be an identical replication. Therefore, the project was conducted in two phases. The first phase tested a simulated Caisson with surrogate contents, and part of a Chute section, and the second phase tested a full chute section. These tests were performed at VJ Technologies Test Facility located in East Haven, CT, as part of the Proof of Design Concept program for studying the feasibility of an in-situ grout/grind/mix/stabilize technology for the remediation of four caissons at the 618-11 Burial Ground at US Department of Energy Hanford Site. The test site was constructed such that multiple testing areas were provided for the evaluation of various tools, equipment and procedures under conditions that simulated the Hanford site, with representative soils and layout dimensions. (authors)« less
Gaia challenging performances verification: combination of spacecraft models and test results
NASA Astrophysics Data System (ADS)
Ecale, Eric; Faye, Frédéric; Chassat, François
2016-08-01
To achieve the ambitious scientific objectives of the Gaia mission, extremely stringent performance requirements have been given to the spacecraft contractor (Airbus Defence and Space). For a set of those key-performance requirements (e.g. end-of-mission parallax, maximum detectable magnitude, maximum sky density or attitude control system stability), this paper describes how they are engineered during the whole spacecraft development process, with a focus on the end-to-end performance verification. As far as possible, performances are usually verified by end-to-end tests onground (i.e. before launch). However, the challenging Gaia requirements are not verifiable by such a strategy, principally because no test facility exists to reproduce the expected flight conditions. The Gaia performance verification strategy is therefore based on a mix between analyses (based on spacecraft models) and tests (used to directly feed the models or to correlate them). Emphasis is placed on how to maximize the test contribution to performance verification while keeping the test feasible within an affordable effort. In particular, the paper highlights the contribution of the Gaia Payload Module Thermal Vacuum test to the performance verification before launch. Eventually, an overview of the in-flight payload calibration and in-flight performance verification is provided.
STUDY ON THE RECYCLING SYSTEM OF WASTE PLASTICS AND MIXED PAPER FROM A LONG-TERM PERSPECTIVE
NASA Astrophysics Data System (ADS)
Fujii, Minoru; Fujita, Tsuyoshi; Chen, Xudong; Ohnishi, Satoshi; Osako, Masahiro; Moriguchi, Yuichi; Yamaguchi, Naohisa
Plastics and mixed paper in municipal solid waste are valuable resources with high calorific value. However, the recycling cost to utilize them tends to be expensive. In addition, recycling system has to be consistent with the reduce of wastes on which should be put higher-priority to lower carbon emission and save resources in the long term. In this paper, we proposed a recycling system (smart recycling system) which consists of a local center an d existing facilities in arterial industries. In the local center, collected waste plastics and mixed paper from household are processed on the same line into a form suitable for transportation and handling in a facility of arterial in dustry which can utilize those wastes effectively. At the same time, a part of plastics with high quality is processed into a recycled resin in the center. It was suggested that, by utilizing existing facilities in arterial industries which have enough and flexible capacity to accept those wastes, the system can be a robust system even if the amount of wastes generation fluctuates widely. The effect of CO2 reduction and cost by installing the system were calculated and it was estimated that 3.5 million ton of additional annual CO2 reduction could be brought in Tokyo and surrounding three prefectures without co nsiderable increase in cost.
Feasibility study of palm-based fuels for hybrid rocket motor applications
NASA Astrophysics Data System (ADS)
Tarmizi Ahmad, M.; Abidin, Razali; Taha, A. Latif; Anudip, Amzaryi
2018-02-01
This paper describes the combined analysis done in pure palm-based wax that can be used as solid fuel in a hybrid rocket engine. The measurement of pure palm wax calorific value was performed using a bomb calorimeter. An experimental rocket engine and static test stand facility were established. After initial measurement and calibration, repeated procedures were performed. Instrumentation supplies carried out allow fuel regression rate measurements, oxidizer mass flow rates and stearic acid rocket motors measurements. Similar tests are also carried out with stearate acid (from palm oil by-products) dissolved with nitrocellulose and bee solution. Calculated data and experiments show that rates and regression thrust can be achieved even in pure-tested palm-based wax. Additionally, palm-based wax is mixed with beeswax characterized by higher nominal melting temperatures to increase moisturizing points to higher temperatures without affecting regression rate values. Calorie measurements and ballistic experiments were performed on this new fuel formulation. This new formulation promises driving applications in a wide range of temperatures.
Regan, S. P.; Epstein, R.; Hammel, B. A.; ...
2012-03-30
Ignition of an inertial confinement fusion (ICF) target depends on the formation of a central hot spot with sufficient temperature and areal density. Radiative and conductive losses from the hot spot can be enhanced by hydrodynamic instabilities. The concentric spherical layers of current National Ignition Facility (NIF) ignition targets consist of a plastic ablator surrounding 2 a thin shell of cryogenic thermonuclear fuel (i.e., hydrogen isotopes), with fuel vapor filling the interior volume. The Rev. 5 ablator is doped with Ge to minimize preheat of the ablator closest to the DT ice caused by Au M-band emission from the hohlraummore » x-ray drive. Richtmyer–Meshkov and Rayleigh–Taylor hydrodynamic instabilities seeded by high-mode (50 < t < 200) ablator-surface perturbations can cause Ge-doped ablator to mix into the interior of the shell at the end of the acceleration phase. As the shell decelerates, it compresses the fuel vapor, forming a hot spot. K-shell line emission from the ionized Ge that has penetrated into the hot spot provides an experimental signature of hot-spot mix. The Ge emission from tritium–hydrogen–deuterium (THD) and DT cryogenic targets and gas-filled plastic shell capsules, which replace the THD layer with a massequivalent CH layer, was examined. The inferred amount of hot-spot mix mass, estimated from the Ge K-shell line brightness using a detailed atomic physics code, is typically below the 75 ng allowance for hot-spot mix. Furthermore, predictions of a simple mix model, based on linear growth of the measured surface-mass modulations, are consistent with the experimental results.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Regan, S. P.; Epstein, R.; Hammel, B. A.
Ignition of an inertial confinement fusion (ICF) target depends on the formation of a central hot spot with sufficient temperature and areal density. Radiative and conductive losses from the hot spot can be enhanced by hydrodynamic instabilities. The concentric spherical layers of current National Ignition Facility (NIF) ignition targets consist of a plastic ablator surrounding 2 a thin shell of cryogenic thermonuclear fuel (i.e., hydrogen isotopes), with fuel vapor filling the interior volume. The Rev. 5 ablator is doped with Ge to minimize preheat of the ablator closest to the DT ice caused by Au M-band emission from the hohlraummore » x-ray drive. Richtmyer–Meshkov and Rayleigh–Taylor hydrodynamic instabilities seeded by high-mode (50 < t < 200) ablator-surface perturbations can cause Ge-doped ablator to mix into the interior of the shell at the end of the acceleration phase. As the shell decelerates, it compresses the fuel vapor, forming a hot spot. K-shell line emission from the ionized Ge that has penetrated into the hot spot provides an experimental signature of hot-spot mix. The Ge emission from tritium–hydrogen–deuterium (THD) and DT cryogenic targets and gas-filled plastic shell capsules, which replace the THD layer with a massequivalent CH layer, was examined. The inferred amount of hot-spot mix mass, estimated from the Ge K-shell line brightness using a detailed atomic physics code, is typically below the 75 ng allowance for hot-spot mix. Furthermore, predictions of a simple mix model, based on linear growth of the measured surface-mass modulations, are consistent with the experimental results.« less
Energy Systems Test Area (ESTA). Power Systems Test Facilities
NASA Technical Reports Server (NTRS)
Situ, Cindy H.
2010-01-01
This viewgraph presentation provides a detailed description of the Johnson Space Center's Power Systems Facility located in the Energy Systems Test Area (ESTA). Facilities and the resources used to support power and battery systems testing are also shown. The contents include: 1) Power Testing; 2) Power Test Equipment Capabilities Summary; 3) Source/Load; 4) Battery Facilities; 5) Battery Test Equipment Capabilities Summary; 6) Battery Testing; 7) Performance Test Equipment; 8) Battery Test Environments; 9) Battery Abuse Chambers; 10) Battery Abuse Capabilities; and 11) Battery Test Area Resources.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pickenheim, B.; Hansen, E.; Leishear, R.
A 10-inch READCO mixer is used for mixing the premix (45 (wt%) fly ash, 45 wt% slag, and 10 wt% portland cement) with salt solution in the Saltstone Production Facility (SPF). The Saltstone grout free falls into the grout hopper which feeds the suction line leading to the Watson SPX 100 duplex hose pump. The Watson SPX 100 pumps the grout through approximately 1500 feet of piping prior to being discharged into the Saltstone Disposal Facility (SDF) vaults. The existing grout hopper has been identified by the Saltstone Enhanced Low Activity Waste Disposal (ELAWD) project for re-design. The current nominalmore » working volume of this hopper is 12 gallons and does not permit handling an inadvertent addition of excess dry feeds. Saltstone Engineering has proposed a new hopper tank that will have a nominal working volume of 300 gallons and is agitated with a mechanical agitator. The larger volume hopper is designed to handle variability in the output of the READCO mixer and process upsets without entering set back during processing. The objectives of this task involve scaling the proposed hopper design and testing the scaled hopper for the following processing issues: (1) The effect of agitation on radar measurement. Formation of a vortex may affect the ability to accurately measure the tank level. The agitator was run at varying speeds and with varying grout viscosities to determine what parameters cause vortex formation and whether measurement accuracy is affected. (2) A dry feeds over addition. Engineering Calculating X-ESR-Z-00017 1 showed that an additional 300 pounds of dry premix added to a 300 gallon working volume would lower the water to premix ratio (W/P) from the nominal 0.60 to 0.53 based on a Salt Waste Processing Facility (SWPF) salt simulant. A grout with a W/P of 0.53 represents the upper bound of grout rheology that could be processed at the facility. A scaled amount of dry feeds will be added into the hopper to verify that this is a recoverable situation. (3) The necessity of baffles in the hopper. The preference of the facility is not to have baffles in the hopper; however, if the initial testing indicates inadequate agitation or difficulties with the radar measurement, baffles will be tested.« less
Kalantari, Saleh; Snell, Robin
2017-07-01
This study was a post-occupancy evaluation (POE) to examine the effectiveness of three specific design innovations in a mental healthcare facility. In addition to collecting data about the impact of these specific designs, the study provides a model for the broader implementation of POE approaches in the mental healthcare context. POEs in general healthcare settings have been shown to lead to better work environments and better outcomes for patients. Despite growing evidence of the value provided by POE studies, the industry has been somewhat slow to adopt their regular use, in part due to unfamiliarity with the POE process. This is particularly true in mental healthcare contexts, where POE studies remain virtually nonexistent. In-depth interviews and a widely distributed, anonymous survey were used to collect hospital staff perceptions and feedback regarding the impact of specific design features. The hospital staff were quite enthusiastic about two of the design innovations studied here (a new wayfinding strategy and the use of vibrant colors in specific areas of the facility). The third innovation, open-style communication centers, elicited more mixed evaluations. The results include extensive hypothesis testing about the effects of each innovation as well as narrative discussions of their pros and cons. The study generated new knowledge about three specific mental healthcare design innovations and provides a model for the practical implementation of a POE approach in mental healthcare contexts. The results are particularly relevant for designers who are considering innovative strategies in future mental healthcare facilities.
Upgrade of the cryogenic CERN RF test facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pirotte, O.; Benda, V.; Brunner, O.
2014-01-29
With the large number of superconducting radiofrequency (RF) cryomodules to be tested for the former LEP and the present LHC accelerator a RF test facility was erected early in the 1990’s in the largest cryogenic test facility at CERN located at Point 18. This facility consisted of four vertical test stands for single cavities and originally one and then two horizontal test benches for RF cryomodules operating at 4.5 K in saturated helium. CERN is presently working on the upgrade of its accelerator infrastructure, which requires new superconducting cavities operating below 2 K in saturated superfluid helium. Consequently, the RFmore » test facility has been renewed in order to allow efficient cavity and cryomodule tests in superfluid helium and to improve its thermal performances. The new RF test facility is described and its performances are presented.« less
New NREL Research Facility Slashes Energy Use by 66 Percent
Thermal Test Facility, which serves as a showcase of energy-saving features and the home of NREL's cutting technologies now being developed at the Thermal Test Facility will help us reach this goal." The facility energy-efficient building design, NREL's Thermal Test Facility houses sophisticated equipment for
NASA Technical Reports Server (NTRS)
Kuchar, A. P.; Chamberlin, R.
1983-01-01
As part of the NASA Energy Efficient Engine program, scale-model performance tests of a mixed flow exhaust system were conducted. The tests were used to evaluate the performance of exhaust system mixers for high-bypass, mixed-flow turbofan engines. The tests indicated that: (1) mixer penetration has the most significant affect on both mixing effectiveness and mixer pressure loss; (2) mixing/tailpipe length improves mixing effectiveness; (3) gap reduction between the mixer and centerbody increases high mixing effectiveness; (4) mixer cross-sectional shape influences mixing effectiveness; (5) lobe number affects mixing degree; and (6) mixer aerodynamic pressure losses are a function of secondary flows inherent to the lobed mixer concept.
DOE Office of Scientific and Technical Information (OSTI.GOV)
LaFreniere, L.
The Commodity Credit Corporation (CCC), an agency of the U.S. Department of Agriculture (USDA), formerly operated a grain storage facility approximately 1,100 ft north of Centralia from 1949 until 1971. Subsequently, a concrete mixing plant operated on the site (FSA 1997). None of the CCC/USDA structures remain, though belowgrade foundations related to structures associated with the concrete mixing operations are evident. Two additional grain storage facilities currently exist in and near Centralia: the Nemaha County Co-op, approximately 4,000 ft south of the former CCC/USDA facility, and a private grain storage facility near the Don Morris residence, 3,500 ft north ofmore » the former CCC/USDA facility (Figure 1.1). The property on which the former facility was located is currently owned by Jeanne Burdett Lacky of Seneca, Kansas. In August-September 1998 the Kansas Department of Health and Environment (KDHE) conducted preliminary investigations at the former CCC/USDA facility, on the basis of the detection of carbon tetrachloride in the domestic well at the Don Morris residence (north of the former CCC/USDA facility). Prior to 1986, commercial grain fumigants containing carbon tetrachloride were commonly used by the CCC/USDA and the grain storage industry to preserve grain. The details of previous investigations in the area and a summary of the findings were reported previously (Argonne 2002a). Because the KDHE detected carbon tetrachloride in groundwater and soil at the former CCC/USDA facility at Centralia that might be related to historical use of carbon tetrachloride-based grain fumigants at the facility, the CCC/USDA is conducting an environmental site investigation to determine the source(s) and extent of the carbon tetrachloride contamination at the former facility near Centralia and to assess whether the contamination requires remedial action. The town of Centralia and all residents near the former CCC/USDA facility currently obtain their water from Rural Water District No.3. Therefore, local residents are not drinking or using the contaminated groundwater detected at the former facility. The Environmental Research Division of Argonne National Laboratory is performing the investigation at Centralia on behalf of the CCC/USDA. Argonne is a nonprofit, multidisciplinary research center operated by the University of Chicago for the U.S. Department of Energy (DOE). The CCC/USDA has entered into an interagency agreement with DOE, under which Argonne provides technical assistance to the CCC/USDA with environmental site characterization and remediation at its former grain storage facilities. At these former facilities, Argonne is applying its QuickSite{reg_sign} environmental site characterization methodology. QuickSite is Argonne's proprietary implementation system for the expedited site characterization process. This methodology has been applied successfully at a number of former CCC/USDA facilities in Nebraska and Kansas and has been adopted by the American Society for Testing and Materials (ASTM 1998) as standard practice for environmental site characterization. Argonne's investigations are conducted with a phased approach. Phase I focuses primarily on the investigation and evaluation of geology, hydrogeology, and hydrogeochemistry to identify potential contaminant pathways at a site. Phase II focuses on delineating the contamination present in both soil and aquifers along the potential migration pathways. Phase I of Argonne's investigation was conducted in March-April 2002. The results and findings of the Phase I investigation at Centralia were reported previously (Argonne 2003). This report documents the findings of the Phase II activities at Centralia. Section 1 provides a brief history of the area, a review of the Phase I results and conclusions, technical objectives for the Phase II investigation, and a brief description of the sections contained in this report. Section 2 describes the investigative methods used during the Phase II investigation. Section 3 presents all of the data obtained during the investigation. Section 4 describes the interpretation of the pertinent data used to meet the technical objectives of the investigation. Section 5 presents the conclusions of the investigation relative to the technical objectives and outlines further recommendations.« less
A methodology for selecting optimum organizations for space communities
NASA Technical Reports Server (NTRS)
Ragusa, J. M.
1978-01-01
This paper suggests that a methodology exists for selecting optimum organizations for future space communities of various sizes and purposes. Results of an exploratory study to identify an optimum hypothetical organizational structure for a large earth-orbiting multidisciplinary research and applications (R&A) Space Base manned by a mixed crew of technologists are presented. Since such a facility does not presently exist, in situ empirical testing was not possible. Study activity was, therefore, concerned with the identification of a desired organizational structural model rather than the empirical testing of it. The principal finding of this research was that a four-level project type 'total matrix' model will optimize the effectiveness of Space Base technologists. An overall conclusion which can be reached from the research is that application of this methodology, or portions of it, may provide planning insights for the formal organizations which will be needed during the Space Industrialization Age.
Vibration and Acoustic Test Facility (VATF): User Test Planning Guide
NASA Technical Reports Server (NTRS)
Fantasia, Peter M.
2011-01-01
Test process, milestones and inputs are unknowns to first-time users of the VATF. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.
Private equity ownership and nursing home financial performance.
Pradhan, Rohit; Weech-Maldonado, Robert; Harman, Jeffrey S; Laberge, Alex; Hyer, Kathryn
2013-01-01
Private equity has acquired multiple large nursing home chains within the last few years; by 2009, it owned nearly 1,900 nursing homes. Private equity is said to improve the financial performance of acquired facilities. However, no study has yet examined the financial performance of private equity nursing homes, ergo this study. The primary purpose of this study is to understand the financial performance of private equity nursing homes and how it compares with other investor-owned facilities. It also seeks to understand the approach favored by private equity to improve financial performance-for instance, whether they prefer to cut costs or maximize revenues or follow a mixed approach. Secondary data from Medicare cost reports, the Online Survey, Certification and Reporting, Area Resource File, and Brown University's Long-term Care Focus data set are combined to construct a longitudinal data set for the study period 2000-2007. The final sample is 2,822 observations after eliminating all not-for-profit, independent, and hospital-based facilities. Dependent financial variables consist of operating revenues and costs, operating and total margins, payer mix (census Medicare, census Medicaid, census other), and acuity index. Independent variables primarily reflect private equity ownership. The study was analyzed using ordinary least squares, gamma distribution with log link, logit with binomial family link, and logistic regression. Private equity nursing homes have higher operating margin as well as total margin; they also report higher operating revenues and costs. No significant differences in payer mix are noted. Results suggest that private equity delivers superior financial performance compared with other investor-owned nursing homes. However, causes for concern remain particularly with the long-term financial sustainability of these facilities.
NASA Astrophysics Data System (ADS)
Chadwick, J.; Turner, A.; Collins, E.
2015-12-01
The Woodlark Spreading Center (WSC) to the east of Papua New Guinea separates the Indo-Australian plate and Solomon Sea microplate. At its eastern terminus, the WSC is being subducted at the New Britain trench, forming a triple junction near the New Georgia Group arc in the Solomon Islands. Previous studies have shown that lavas recovered from greater than 100 km from the trench on the WSC are N-MORB, but closer to the trench they have arc-like Sr-Nd-Pb isotopic ratios, enrichments in LILE, and depletions in HFSE. In the complex triple junction area of the WSC on the Simbo and Ghizo Ridges, island arc tholeiites to medium-K calc-alkaline andesites and dacites have been recovered, many with trace element and isotopic characteristics that are similar to the true arc lavas in the New Georgia Group on the other side of the trench. We suggest that subduction-modified arc mantle migrates through slab windows created by the subduction of the WSC as the plates continue to diverge after subduction. This transfer of mantle across the plate boundary leads to variable mixing between arc and N-MORB end-members, forming the hybrid to arc-like lavas recovered on the WSC. To test this hypothesis and to characterize the end-member compositions, we have analyzed melt inclusions in olivine, pyroxene, and plagioclase phenocrysts in Simbo and Ghizo Ridge lava samples. Major elements were analyzed using the electron microprobe facility at Fayetteville State University and volatiles were analyzed on the ion probe facility at Woods Hole Oceanographic Institution. The melt inclusions show a wide diversity of magmas from basalts to dacites, and mixing modeling shows that most Woodlark Spreading Center lava compositions are explained by mixing between the most extreme mafic (MORB) and felsic (arc) inclusion compositions.
Cast Stone Formulation At Higher Sodium Concentrations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fox, K. M.; Roberts, K. A.; Edwards, T. B.
2013-09-17
A low temperature waste form known as Cast Stone is being considered to provide supplemental Low Activity Waste (LAW) immobilization capacity for the Hanford site. Formulation of Cast Stone at high sodium concentrations is of interest since a significant reduction in the necessary volume of Cast Stone and subsequent disposal costs could be achieved if an acceptable waste form can be produced with a high sodium molarity salt solution combined with a high water to premix (or dry blend) ratio. The objectives of this study were to evaluate the factors involved with increasing the sodium concentration in Cast Stone, includingmore » production and performance properties and the retention and release of specific components of interest. Three factors were identified for the experimental matrix: the concentration of sodium in the simulated salt solution, the water to premix ratio, and the blast furnace slag portion of the premix. The salt solution simulants used in this study were formulated to represent the overall average waste composition. The cement, blast furnace slag, and fly ash were sourced from a supplier in the Hanford area in order to be representative. The test mixes were prepared in the laboratory and fresh properties were measured. Fresh density increased with increasing sodium molarity and with decreasing water to premix ratio, as expected given the individual densities of these components. Rheology measurements showed that all of the test mixes produced very fluid slurries. The fresh density and rheology data are of potential value in designing a future Cast Stone production facility. Standing water and density gradient testing showed that settling is not of particular concern for the high sodium compositions studied. Heat of hydration measurements may provide some insight into the reactions that occur within the test mixes, which may in turn be related to the properties and performance of the waste form. These measurements showed that increased sodium concentration in the salt solution reduced the time to peak heat flow, and reducing the amount of slag in the premix increased the time to peak heat flow. These observations may help to describe some of the cured properties of the samples, in particular the differences in compressive strength observed after 28 and 90 days of curing. Samples were cured for at least 28 days at ambient temperature in the laboratory prior to cured properties analyses. The low activity waste form for disposal at the Hanford Site is required to have a compressive strength of at least 500 psi. After 28 days of curing, several of the test mixes had mean compressive strengths that were below the 500 psi requirement. Higher sodium concentrations and higher water to premix ratios led to reduced compressive strength. Higher fly ash concentrations decreased the compressive strength after 28 days of curing. This may be explained in that the cementitious phases matured more quickly in the mixes with higher concentrations of slag, as evidenced by the data for the time to peak heat generation. All of the test mixes exhibited higher mean compressive strengths after 90 days of curing, with only one composition having a mean compressive strength of less than 500 psi. Leach indices were determined for the test mixes for contaminants of interest. The leaching performance of the mixes evaluated in this study was not particularly sensitive to the factors used in the experimental design. This may be beneficial in demonstrating that the performance of the waste form is robust with respect to changes in the mix composition. The results of this study demonstrate the potential to achieve significantly higher waste loadings in Cast Stone and other low temperature, cementitious waste forms. Additional work is needed to elucidate the hydration mechanisms occurring in Cast Stone formulated with highly concentrated salt solutions since these reactions are responsible for determining the performance of the cured waste form. The thermal analyses completed in this study provide some preliminary insight, although the limited range of the factors in the test matrix hindered the identification of individual component effects. Future work should involve broader factor ranges to identify the roles played by each of the components in the mix via thermal analyses, analytical microscopy, and characterization of phase formation.« less
Cast Stone Formulation At Higher Sodium Concentrations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fox, K. M.; Edwards, T. A.; Roberts, K. B.
2013-10-02
A low temperature waste form known as Cast Stone is being considered to provide supplemental Low Activity Waste (LAW) immobilization capacity for the Hanford site. Formulation of Cast Stone at high sodium concentrations is of interest since a significant reduction in the necessary volume of Cast Stone and subsequent disposal costs could be achieved if an acceptable waste form can be produced with a high sodium molarity salt solution combined with a high water to premix (or dry blend) ratio. The objectives of this study were to evaluate the factors involved with increasing the sodium concentration in Cast Stone, includingmore » production and performance properties and the retention and release of specific components of interest. Three factors were identified for the experimental matrix: the concentration of sodium in the simulated salt solution, the water to premix ratio, and the blast furnace slag portion of the premix. The salt solution simulants used in this study were formulated to represent the overall average waste composition. The cement, blast furnace slag, and fly ash were sourced from a supplier in the Hanford area in order to be representative. The test mixes were prepared in the laboratory and fresh properties were measured. Fresh density increased with increasing sodium molarity and with decreasing water to premix ratio, as expected given the individual densities of these components. Rheology measurements showed that all of the test mixes produced very fluid slurries. The fresh density and rheology data are of potential value in designing a future Cast Stone production facility. Standing water and density gradient testing showed that settling is not of particular concern for the high sodium compositions studied. Heat of hydration measurements may provide some insight into the reactions that occur within the test mixes, which may in turn be related to the properties and performance of the waste form. These measurements showed that increased sodium concentration in the salt solution reduced the time to peak heat flow, and reducing the amount of slag in the premix increased the time to peak heat flow. These observations may help to describe some of the cured properties of the samples, in particular the differences in compressive strength observed after 28 and 90 days of curing. Samples were cured for at least 28 days at ambient temperature in the laboratory prior to cured properties analyses. The low activity waste form for disposal at the Hanford Site is required to have a compressive strength of at least 500 psi. After 28 days of curing, several of the test mixes had mean compressive strengths that were below the 500 psi requirement. Higher sodium concentrations and higher water to premix ratios led to reduced compressive strength. Higher fly ash concentrations decreased the compressive strength after 28 days of curing. This may be explained in that the cementitious phases matured more quickly in the mixes with higher concentrations of slag, as evidenced by the data for the time to peak heat generation. All of the test mixes exhibited higher mean compressive strengths after 90 days of curing, with only one composition having a mean compressive strength of less than 500 psi. Leach indices were determined for the test mixes for contaminants of interest. The leaching performance of the mixes evaluated in this study was not particularly sensitive to the factors used in the experimental design. This may be beneficial in demonstrating that the performance of the waste form is robust with respect to changes in the mix composition. The results of this study demonstrate the potential to achieve significantly higher waste loadings in Cast Stone and other low temperature, cementitious waste forms. Additional work is needed to elucidate the hydration mechanisms occurring in Cast Stone formulated with highly concentrated salt solutions since these reactions are responsible for determining the performance of the cured waste form. The thermal analyses completed in this study provide some preliminary insight, although the limited range of the factors in the test matrix hindered the identification of individual component effects. Future work should involve broader factor ranges to identify the roles played by each of the components in the mix via thermal analyses, analytical microscopy, and characterization of phase formation.« less
Cast Stone Formulation At Higher Sodium Concentrations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fox, K. M.; Roberts, K. A.; Edwards, T. B.
2014-02-28
A low temperature waste form known as Cast Stone is being considered to provide supplemental Low Activity Waste (LAW) immobilization capacity for the Hanford site. Formulation of Cast Stone at high sodium concentrations is of interest since a significant reduction in the necessary volume of Cast Stone and subsequent disposal costs could be achieved if an acceptable waste form can be produced with a high sodium molarity salt solution combined with a high water to premix (or dry blend) ratio. The objectives of this study were to evaluate the factors involved with increasing the sodium concentration in Cast Stone, includingmore » production and performance properties and the retention and release of specific components of interest. Three factors were identified for the experimental matrix: the concentration of sodium in the simulated salt solution, the water to premix ratio, and the blast furnace slag portion of the premix. The salt solution simulants used in this study were formulated to represent the overall average waste composition. The cement, blast furnace slag, and fly ash were sourced from a supplier in the Hanford area in order to be representative. The test mixes were prepared in the laboratory and fresh properties were measured. Fresh density increased with increasing sodium molarity and with decreasing water to premix ratio, as expected given the individual densities of these components. Rheology measurements showed that all of the test mixes produced very fluid slurries. The fresh density and rheology data are of potential value in designing a future Cast Stone production facility. Standing water and density gradient testing showed that settling is not of particular concern for the high sodium compositions studied. Heat of hydration measurements may provide some insight into the reactions that occur within the test mixes, which may in turn be related to the properties and performance of the waste form. These measurements showed that increased sodium concentration in the salt solution reduced the time to peak heat flow, and reducing the amount of slag in the premix increased the time to peak heat flow. These observations may help to describe some of the cured properties of the samples, in particular the differences in compressive strength observed after 28 and 90 days of curing. Samples were cured for at least 28 days at ambient temperature in the laboratory prior to cured properties analyses. The low activity waste form for disposal at the Hanford Site is required to have a compressive strength of at least 500 psi. After 28 days of curing, several of the test mixes had mean compressive strengths that were below the 500 psi requirement. Higher sodium concentrations and higher water to premix ratios led to reduced compressive strength. Higher fly ash concentrations decreased the compressive strength after 28 days of curing. This may be explained in that the cementitious phases matured more quickly in the mixes with higher concentrations of slag, as evidenced by the data for the time to peak heat generation. All of the test mixes exhibited higher mean compressive strengths after 90 days of curing, with only one composition having a mean compressive strength of less than 500 psi. Leachability indices were determined for the test mixes for contaminants of interest. The leaching performance of the mixes evaluated in this study was not particularly sensitive to the factors used in the experimental design. This may be beneficial in demonstrating that the performance of the waste form is robust with respect to changes in the mix composition. The results of this study demonstrate the potential to achieve significantly higher waste loadings in Cast Stone and other low temperature, cementitious waste forms. Additional work is needed to elucidate the hydration mechanisms occurring in Cast Stone formulated with highly concentrated salt solutions since these reactions are responsible for determining the performance of the cured waste form. The thermal analyses completed in this study provide some preliminary insight, although the limited range of the factors in the test matrix hindered the identification of individual component effects. Future work should involve broader factor ranges to identify the roles played by each of the components in the mix via thermal analyses, analytical microscopy, and characterization of phase formation.« less
26 CFR 1.141-6 - Allocation and accounting rules.
Code of Federal Regulations, 2010 CFR
2010-04-01
.... Thus, allocations generally may be made using any reasonable, consistently applied accounting method... of proceeds to property. [Reserved] (c) Special rules for mixed use facilities. [Reserved] (d...
Kaya, M S; Güçlü, B; Schimmel, M; Akyüz, S
2017-11-01
The unappealing taste of the chewing material and the time-consuming repetitive task in masticatory performance tests using artificial foodstuff may discourage children from performing natural chewing movements. Therefore, the aim was to determine the validity and reliability of a two-colour chewing gum mixing ability test for masticatory performance (MP) assessment in mixed dentition children. Masticatory performance was tested in two groups: systemically healthy fully dentate young adults and children in mixed dentition. Median particle size was assessed using a comminution test, and a two-colour chewing gum mixing ability test was applied for MP analysis. Validity was tested with Pearson correlation, and reliability was tested with intra-class correlation coefficient, Pearson correlation and Bland-Altman plots. Both comminution and two-colour chewing gum mixing ability tests revealed statistically significant MP differences between children (n = 25) and adults (n = 27, both P < 0·01). Pearson correlation between comminution and two-colour chewing gum mixing ability tests was positive and significant (r = 0·418, P = 0·002). Correlations for interobserver reliability and test-retest values were significant (r = 0·990, P = 0·0001 and r = 0·995, P = 0·0001). Although both methods could discriminate MP differences, the comminution test detected these differences generally in a wider range compared to two-colour chewing gum mixing ability test. However, considering the high reliability of the results, the two-colour chewing gum mixing ability test can be used to assess masticatory performance in children, especially at non-clinical settings. © 2017 John Wiley & Sons Ltd.
Mixed waste focus area alternative technologies workshop
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borduin, L.C.; Palmer, B.A.; Pendergrass, J.A.
1995-05-24
This report documents the Mixed Waste Focus Area (MWFA)-sponsored Alternative Technology Workshop held in Salt Lake City, Utah, from January 24--27, 1995. The primary workshop goal was identifying potential applications for emerging technologies within the Options Analysis Team (OAT) ``wise`` configuration. Consistent with the scope of the OAT analysis, the review was limited to the Mixed Low-Level Waste (MLLW) fraction of DOE`s mixed waste inventory. The Los Alamos team prepared workshop materials (databases and compilations) to be used as bases for participant review and recommendations. These materials derived from the Mixed Waste Inventory Report (MWIR) data base (May 1994), themore » Draft Site Treatment Plan (DSTP) data base, and the OAT treatment facility configuration of December 7, 1994. In reviewing workshop results, the reader should note several caveats regarding data limitations. Link-up of the MWIR and DSTP data bases, while representing the most comprehensive array of mixed waste information available at the time of the workshop, requires additional data to completely characterize all waste streams. A number of changes in waste identification (new and redefined streams) occurred during the interval from compilation of the data base to compilation of the DSTP data base with the end result that precise identification of radiological and contaminant characteristics was not possible for these streams. To a degree, these shortcomings compromise the workshop results; however, the preponderance of waste data was linked adequately, and therefore, these analyses should provide useful insight into potential applications of alternative technologies to DOE MLLW treatment facilities.« less
Evaluation of an Ejector Ramjet Based Propulsion System for Air-Breathing Hypersonic Flight
NASA Technical Reports Server (NTRS)
Thomas, Scott R.; Perkins, H. Douglas; Trefny, Charles J.
1997-01-01
A Rocket Based Combined Cycle (RBCC) engine system is designed to combine the high thrust to weight ratio of a rocket along with the high specific impulse of a ramjet in a single, integrated propulsion system. This integrated, combined cycle propulsion system is designed to provide higher vehicle performance than that achievable with a separate rocket and ramjet. The RBCC engine system studied in the current program is the Aerojet strutjet engine concept, which is being developed jointly by a government-industry team as part of the Air Force HyTech program pre-PRDA activity. The strutjet is an ejector-ramjet engine in which small rocket chambers are embedded into the trailing edges of the inlet compression struts. The engine operates as an ejector-ramjet from take-off to slightly above Mach 3. Above Mach 3 the engine operates as a ramjet and transitions to a scramjet at high Mach numbers. For space launch applications the rockets would be re-ignited at a Mach number or altitude beyond which air-breathing propulsion alone becomes impractical. The focus of the present study is to develop and demonstrate a strutjet flowpath using hydrocarbon fuel at up to Mach 7 conditions. Freejet tests of a candidate flowpath for this RBCC engine were conducted at the NASA Lewis Research Center's Hypersonic Tunnel Facility between July and September 1996. This paper describes the engine flowpath and installation, outlines the primary objectives of the program, and describes the overall results of this activity. Through this program 15 full duration tests, including 13 fueled tests were made. The first major achievement was the further demonstration of the HTF capability. The facility operated at conditions up to 1950 K and 7.34 MPa, simulating approximately Mach 6.6 flight. The initial tests were unfueled and focused on verifying both facility and engine starting. During these runs additional aerodynamic appliances were incorporated onto the facility diffuser to enhance starting. Both facility and engine starting were achieved. Further, the static pressure distributions compared well with the results previously obtained in a 40% subscale flowpath study conducted in the LERC 1X1 supersonic wind tunnel (SWT), as well as the results of CFD analysis. Fueled performance results were obtained for the engine at both simulated Mach 6 (1670 K) and Mach 6.6 (1950 K) conditions. For all these tests the primary fuel was liquid JP-10 with gaseous silane (a mixture of 20% SiH4 and 80% H2 by volume) as an ignitor/pilot. These tests verified performance of this engine flowpath in a freejet mode. High combustor pressures were reached and significant changes in axial force were achieved due to combustion. Future test plans include redistributing the fuel to improve mixing, and consequently performance, at higher equivalence ratios.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spore, J.W.; Cappiello, M.W.; Dotson, P.J.
The analytical support in 1985 for Cylindrical Core Test Facility (CCTF), Slab Core Test Facility (SCTF), and Upper Plenum Test Facility (UPTF) tests involves the posttest analysis of 16 tests that have already been run in the CCTF and the SCTF and the pretest analysis of 3 tests to be performed in the UPTF. Posttest analysis is used to provide insight into the detailed thermal-hydraulic phenomena occurring during the refill and reflood tests performed in CCTF and SCTF. Pretest analysis is used to ensure that the test facility is operated in a manner consistent with the expected behavior of anmore » operating full-scale plant during an accident. To obtain expected behavior of a plant during an accident, two plant loss-of-coolant-accident (LOCA) calculations were performed: a 200% cold-leg-break LOCA calculation for a 2772 MW(t) Babcock and Wilcox plant and a 200% cold-leg-break LOCA calculation for a 3315 MW(t) Westinghouse plant. Detailed results are presented for several CCTF UPI tests and the Westinghouse plant analysis.« less
Development of a EUV Test Facility at the Marshall Space Flight Center
NASA Technical Reports Server (NTRS)
West, Edward; Pavelitz, Steve; Kobayashi, Ken; Robinson, Brian; Cirtain, Johnathan; Gaskin, Jessica; Winebarger, Amy
2011-01-01
This paper will describe a new EUV test facility that is being developed at the Marshall Space Flight Center (MSFC) to test EUV telescopes. Two flight programs, HiC - high resolution coronal imager (sounding rocket) and SUVI - Solar Ultraviolet Imager (GOES-R), set the requirements for this new facility. This paper will discuss those requirements, the EUV source characteristics, the wavelength resolution that is expected and the vacuum chambers (Stray Light Facility, Xray Calibration Facility and the EUV test chamber) where this facility will be used.
2012-01-01
Background Ambitious UN goals to reduce the mother-to-child transmission of HIV have not been met in much of Sub-Saharan Africa. This paper focuses on the quality of information provision and counseling and disclosure patterns in Burkina Faso, Kenya, Malawi and Uganda to identify how services can be improved to enable better PMTCT outcomes. Methods Our mixed-methods study draws on data obtained through: (1) the MATCH (Multi-country African Testing and Counseling for HIV) study's main survey, conducted in 2008-09 among clients (N = 408) and providers at health facilities offering HIV Testing and Counseling (HTC) services; 2) semi-structured interviews with a sub-set of 63 HIV-positive women on their experiences of stigma, disclosure, post-test counseling and access to follow-up psycho-social support; (3) in-depth interviews with key informants and PMTCT healthcare workers; and (4) document study of national PMTCT policies and guidelines. We quantitatively examined differences in the quality of counseling by country and by HIV status using Fisher's exact tests. Results The majority of pregnant women attending antenatal care (80-90%) report that they were explained the meaning of the tests, explained how HIV can be transmitted, given advice on prevention, encouraged to refer their partners for testing, and given time to ask questions. Our qualitative findings reveal that some women found testing regimes to be coercive, while disclosure remains highly problematic. 79% of HIV-positive pregnant women reported that they generally keep their status secret; only 37% had disclosed to their husband. Conclusion To achieve better PMTCT outcomes, the strategy of testing women in antenatal care (perceived as an exclusively female domain) when they are already pregnant needs to be rethought. When scaling up HIV testing programs, it is particularly important that issues of partner disclosure are taken seriously. PMID:22236097
Hardon, Anita; Vernooij, Eva; Bongololo-Mbera, Grace; Cherutich, Peter; Desclaux, Alice; Kyaddondo, David; Ky-Zerbo, Odette; Neuman, Melissa; Wanyenze, Rhoda; Obermeyer, Carla
2012-01-11
Ambitious UN goals to reduce the mother-to-child transmission of HIV have not been met in much of Sub-Saharan Africa. This paper focuses on the quality of information provision and counseling and disclosure patterns in Burkina Faso, Kenya, Malawi and Uganda to identify how services can be improved to enable better PMTCT outcomes. Our mixed-methods study draws on data obtained through: (1) the MATCH (Multi-country African Testing and Counseling for HIV) study's main survey, conducted in 2008-09 among clients (N = 408) and providers at health facilities offering HIV Testing and Counseling (HTC) services; 2) semi-structured interviews with a sub-set of 63 HIV-positive women on their experiences of stigma, disclosure, post-test counseling and access to follow-up psycho-social support; (3) in-depth interviews with key informants and PMTCT healthcare workers; and (4) document study of national PMTCT policies and guidelines. We quantitatively examined differences in the quality of counseling by country and by HIV status using Fisher's exact tests. The majority of pregnant women attending antenatal care (80-90%) report that they were explained the meaning of the tests, explained how HIV can be transmitted, given advice on prevention, encouraged to refer their partners for testing, and given time to ask questions. Our qualitative findings reveal that some women found testing regimes to be coercive, while disclosure remains highly problematic. 79% of HIV-positive pregnant women reported that they generally keep their status secret; only 37% had disclosed to their husband. To achieve better PMTCT outcomes, the strategy of testing women in antenatal care (perceived as an exclusively female domain) when they are already pregnant needs to be rethought. When scaling up HIV testing programs, it is particularly important that issues of partner disclosure are taken seriously.
NASA Astrophysics Data System (ADS)
Crowe, B.; Black, P.; Tauxe, J.; Yucel, V.; Rawlinson, S.; Colarusso, A.; DiSanza, F.
2001-12-01
The National Nuclear Security Administration, Nevada Operations Office (NNSA/NV) operates and maintains two active facilities on the Nevada Test Site (NTS) that dispose Department of Energy (DOE) defense-generated low-level radioactive (LLW), mixed radioactive, and classified waste in shallow trenches, pits and large-diameter boreholes. The operation and maintenance of the LLW disposal sites are self-regulated under DOE Order 435.1, which requires review of a Performance Assessment for four performance objectives: 1) all pathways 25 mrem/yr limit; 2) atmospheric pathways 10 mrem/yr limit; 3) radon flux density of 20 pCi/m2/s; and 4) groundwater resource protection (Safe Drinking Water Act; 4 mrem/yr limit). The inadvertent human intruder is protected under a dual 500- and 100-mrem limit (acute and chronic exposure). In response to the Defense Nuclear Facilities Safety Board Recommendation 92 2, a composite analysis is required that must examine all interacting sources for compliance against both 30 and 100 mrem/yr limits. A small component of classified transuranic waste is buried at intermediate depths in 3-meter diameter boreholes at the Area 5 LLW disposal facility and is assessed through DOE-agreement against the requirements of the Environmental Protection Agency (EPA)'s 40 CFR 191. The hazardous components of mixed LLW are assessed against RCRA requirements. The NTS LLW sites fall directly under three sets of federal regulations and the regulatory differences result not only in organizational challenges, but also in different decision objectives and technical paths to completion. The DOE regulations require deterministic analysis for a 1,000-year compliance assessment supplemented by probabilistic analysis under a long-term maintenance program. The EPA regulations for TRU waste are probabilistically based for a compliance interval of 10,000 years. Multiple steps in the assessments are strongly dependent on assumptions for long-term land use policies. Integrating the different requirements into coherent and consistent sets of conceptual models of the disposal setting, alternative scenarios, and system models of fate, transport and dose-based assessments is technically challenging. Environmental assessments for these sites must be broad-based and flexible to accommodate the multiple objectives.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paladino, Domenico; Auban, Olivier; Zboray, Robert
The benefits of using codes with 3-D capabilities to address safety issues of LWRs will be applicable to both the current generation of nuclear reactors as well to future ALWRs. The phenomena governing the containment response in case of some postulated severe accident scenarios include gas (air, hydrogen, steam) stratification in the containment, gas distribution between containment compartments, wall condensation, etc. These phenomena are driven by buoyant high momentum injection (jets) and/or low momentum injection (plumes). For instance, mixing in the immediate vicinity of the postulated line break is mainly dominated by very high velocity efflux, while low-momentum flows aremore » responsible for most of the transport processes within the containment. A project named SETH is currently in progress under the auspices of 15 OECD countries, with the aim of creating an experimental database suitable to assess the 3-D code capabilities in analyzing key-physical phenomena relevant for LWR safety analysis. This paper describes some results of two SETH tests, performed in the PANDA facility (located at PSI in Switzerland), focusing on plumes flowing near a containment wall. The plumes are generated by injecting a constant amount of steam in one of two interconnected vessels initially filled with air. In one of the two tests the temperature of the injected steam and the initial containment wall and fluid temperatures allowed for condensation during the test. (authors)« less
NASA Tech Briefs, February 2003
NASA Technical Reports Server (NTRS)
2003-01-01
opics covered include: Integrated Electrode Arrays for Neuro-Prosthetic Implants; Eroding Potentiometers; Common/Dependent-Pressure-Vessel Nickel-Hydrogen Batteries; 120-GHz HEMT Oscillator With Surface-Wave-Assisted Antenna; 80-GHz MMIC HEMT Voltage-Controlled Oscillator; High-Energy-Density Capacitors; Microscale Thermal-Transpiration Gas Pump; Instrument for Measuring Temperature of Water; Improved Measurement of Coherence in Presence of Instrument Noise; Compact Instruments Measure Helium-Leak Rates; Irreversible Entropy Production in Two-Phase Mixing Layers; Subsonic and Supersonic Effects in Bose-Einstein Condensate; Nanolaminate Mirrors With "Piston" Figure-Control Actuators; Mixed Conducting Electrodes for Better AMTEC Cells; Process for Encapsulating Protein Crystals; Lightweight, Self-Deployable Wheels; Grease-Resistant O Rings for Joints in Solid Rocket Motors; LabVIEW Serial Driver Software for an Electronic Load; Software Computes Tape-Casting Parameters; Software for Tracking Costs of Mars Projects; Software for Replicating Data Between X.500 and LDAP Directories; The Technical Work Plan Tracking Tool; Improved Multiple-DOF SAW Piezoelectric Motors; Propulsion Flight-Test Fixture; Mechanical Amplifier for a Piezoelectric Transducer; Swell Sleeves for Testing Explosive Devices; Linear Back-Drive Differentials; Miniature Inchworm Actuators Fabricated by Use of LIGA; Using ERF Devices to Control Deployments of Space Structures; High-Temperature Switched-Reluctance Electric Motor; System for Centering a Turbofan in a Nacelle During Tests; Fabricating Composite-Material Structures Containing SMA Ribbons; Optimal Feedback Control of Thermal Networks; Artifacts for Calibration of Submicron Width Measurements; Navigating a Mobile Robot Across Terrain Using Fuzzy Logic; Designing Facilities for Collaborative Operations; and Quantitating Iron in Serum Ferritin by Use of ICP-MS.
Rendigs, Richard R.; Bothner, Michael H.
2004-01-01
This manual describes the operation and testing procedures for two models of a multi-port suspended sediment sampler that are moored in the coastal ocean and that collect samples on a programmable time schedule that can be interrupted to collect during a storm. The ability to sense and collect samples before, during, and after the height of a storm is a unique feature of these instruments because it provides samples during conditions when it is difficult or impossible to sample from a surface ship. The sensors used to trigger storm sampling are a transmissometer or a pressure sensor. The purpose of such samples is to assess composition and concentration of sediment resuspended from the seafloor during storms and subsequently transported within the coastal system. Both light transmission and the standard deviation of pressure from surface waves correlate with the passage of major storms. The instruments successfully identified the onset of storms and collected samples before, during, and after the storm maximum as programmed. The accuracy of determining suspended matter concentrations collected by the sediment sampler has not been fully evaluated. Preliminary laboratory tests using a suspension of muddy sediment collected in a near-bottom sediment trap yielded excellent results. However in laboratory tests with different sediment types, the suspended matter concentrations determined with these samplers became less accurate with increasing average grain size. Future calibration work is necessary and should be conducted in a facility that ideally has a water depth of at least 30 feet to prevent cavitation of the pump that draws sea water through the filters. The test facility should also have the capability for adding suspended matter of known composition and concentration to a fixed volume of seawater that is well mixed.
NASA Astrophysics Data System (ADS)
Mireles, Omar R.
Free-piston Stirling power convertors are under consideration by NASA for service in the Advanced Stirling Radioisotope Generator (ASRG) and Fission Surface Power (FSP) systems to enable aggressive exploration missions by providing a reliable and constant power supply. The ASRG must withstand environmental radiation conditions, while the FSP system must tolerate a mixed neutron and gamma-ray environment resulting from self-irradiation. Stirling-alternators utilize rare earth magnets and a variety of organic materials whose radiation limits dominate service life estimates and shielding requirements. The project objective was to demonstrate the performance of the alternator, identify materials that exhibit excessive radiation sensitivity, identify radiation tolerant substitutes, establish empirical dose limits, and demonstrate the feasibility of cost effective nuclear and radiation tests by selection of the appropriate personnel and test facilities as a function of hardware maturity. The Stirling Alternator Radiation Test Article (SARTA) was constructed from linear alternator components of a Stirling convertor and underwent significant pre-exposure characterization. The SARTA was operated at the Sandia National Laboratories Gamma Irradiation Facility to a dose of over 40 Mrad. Operating performance was within nominal variation, although modestly decreasing trends occurred in later runs as well as the detection of an electrical fault after the final exposure. Post-irradiation disassembly and internal inspection revealed minimal degradation of the majority of the organic components. Radiation testing of organic material coupons was conducted since the majority of the literature was inconsistent. These inconsistencies can be attributed to testing at environmental conditions vastly different than those Stirling-alternator organics will experience during operation. Samples were irradiated at the Texas A&M TRIGA reactor to above expected FSP neutron fluence. A thorough materials evaluation followed and results indicate that the majority of material properties experienced minimal statistically significant change.
Atmospheric Reentry Materials and Structures Evaluation Facility (ARMSEF). User Test Planning Guide
NASA Technical Reports Server (NTRS)
2011-01-01
Test process, milestones and inputs are unknowns to first-time users of the ARMSEF. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.
Mixing enhancement in a scramjet combustor using fuel jet injection swirl
NASA Astrophysics Data System (ADS)
Flesberg, Sonja M.
The scramjet engine has proven to be a viable means of powering a hypersonic vehicle, especially after successful flights of the X-51 WaveRider and various Hy-SHOT test vehicles. The major challenge associated with operating a scramjet engine is the short residence time of the fuel and oxidizer in the combustor. The fuel and oxidizer have only milliseconds to mix, ignite and combust in the combustion chamber. Combustion cannot occur until the fuel and oxidizer are mixed on a molecular level. Therefore the improvement of mixing is of utmost interest since this can increase combustion efficiency. This study investigated mixing enhancement of fuel and oxidizer within the combustion chamber of a scramjet by introducing swirl to the fuel jet. The investigation was accomplished with numerical simulations using STAR-CCM+ computational fluid dynamic software. The geometry of the University of Virginia Supersonic Combustion Facility was used to model the isolator, combustor and nozzle of a scramjet engine for simulation purposes. Experimental data from previous research at the facility was used to verify the simulation model before investigating the effect of fuel jet swirl on mixing. The model used coaxial fuel jet with a swirling annular jet. Single coaxial fuel jet and dual coaxial fuel jet configurations were simulated for the investigation. The coaxial fuel jets were modelled with a swirling annular jet and non-swirling core jet. Numerical analysis showed that fuel jet swirl not only increased mixing and entrainment of the fuel with the oxidizer but the mixing occurred further upstream than without fuel jet swirl. The burning efficiency was calculated for the all the configurations. An increase in burning efficiency indicated an increase in the mixing of H2 with O2. In the case of the single fuel jet models, the maximum burning efficiency increase due to fuel injection jet swirl was 23.3%. The research also investigated the possibility that interaction between two swirling jets would produce increased mixing and to study how the distance between the two fuel injector exits would affect mixing. Three swirl patterns were investigated: 1) the first swirl pattern as viewed by an observer looking downstream had the right fuel annular jet swirling counter clockwise and the left fuel annular jet swirling clockwise, 2) the second swirl pattern as viewed by an observer looking downstream had the right fuel jet swirling clockwise and the left fuel jet swirling counter clockwise, 3) the third swirl pattern as viewed by an observer looking downstream had both the right and left fuel jet swirling in the same clockwise direction. Each one of the swirl patterns were simulated with the distances between the center points of the fuel jets modelled 3, 4, and 5 times the fuel injector radius. The swirl pattern that produced the greatest increase in burning efficiency differed according to the fuel injector spacing. The maximum increase in burning efficiency compared to the corresponding non-swirling two jet baseline case was 24.6% and was produced by the first swirl pattern with the distance between the center points of the fuel jets being 5 times the fuel injector radius. The burning efficiency for the single jet non-swirling baseline case and the first swirl pattern with the distance between the center points of the fuel jets being 5 times the fuel injector radius was 0.70 and 0.90 respectively indicating a 29% increase due to dual fuel injection swirl.
Astronaut Ronald Sega with Wake Shield Facility on test stand at JSC
NASA Technical Reports Server (NTRS)
1991-01-01
The Wake Shield Facility is displayed on a test stand at JSC. Astronaut Ronald M. Sega, mission specialist for STS-60, is seen with the facility during a break in testing in the acoustic and vibration facility at JSC.
Astronaut Ronald Sega with Wake Shield Facility on test stand at JSC
1991-10-09
The Wake Shield Facility is displayed on a test stand at JSC. Astronaut Ronald M. Sega, mission specialist for STS-60, is seen with the facility during a break in testing in the acoustic and vibration facility at JSC.
Feedback Control of a Morphing Chevron for Takeoff and Cruise Noise Reduction
NASA Technical Reports Server (NTRS)
Cabell, Randolph H.; Schiller, Noah H.; Mabe, James H.; Ruggeri, Robert T.; Butler, G. W.
2004-01-01
Noise from commercial high-bypass ratio turbofan engines is generated by turbulent mixing of the hot jet exhaust, fan stream, and ambient air. Serrated aerodynamic devices, known as chevrons, along the trailing edges of a jet engine primary and secondary exhaust nozzle have been shown to reduce jet noise at takeoff and shock-cell noise at cruise conditions. Their optimum shape is a finely tuned compromise between noise-benefit and thrust-loss. The design of a full scale Variable Geometry Chevron (VGC) fan-nozzle incorporating Shape Memory Alloy (SMA) actuators is described in a companion paper. This paper describes the development and testing of a proportional-integral control system that regulates the heating of the SMA actuators to control the VGC s tip immersion. The VGC and control system were tested under representative flow conditions in Boeing s Nozzle Test Facility (NTF). Results from the NTF test which demonstrate controllable immersion of the VGC are described. The paper also describes the correlation between strains and temperatures on the chevron with a photogrammetric measurement of the chevron's tip immersion.
Iraqi Army Facilities Under the Iraq Security Forces Fund, Diyanah and Debecha, Iraq
2008-01-17
reinforcement bars and cast each building’s roof flatwork and horizontal beams to complete the structural aspects of the roof system . Steel header...included a mix of new construction and renovation of existing structures and facilities. The Statement of Requirements and Specifications provided...that renovation of existing structures , when possible, was preferred. In addition, the United States government encouraged the contractor to use
Evaluation of a metering, mixing, and dispensing system for mixing polysulfide adhesive
NASA Technical Reports Server (NTRS)
Evans, Kurt B.
1989-01-01
Tests were performed to evaluate whether a metered mixing system can mix PR-1221 polysulfide adhesive as well as or better than batch-mixed adhesive; also, to evaluate the quality of meter-mixed PR-1860 and PS-875 polysulfide adhesives. These adhesives are candidate replacements for PR-1221 which will not be manufactured in the future. The following material properties were evaluated: peel strength, specific gravity and adhesive components of mixed adhesives, Shore A hardness, tensile adhesion strength, and flow rate. Finally, a visual test called the butterfly test was performed to observe for bubbles and unmixed adhesive. The results of these tests are reported and discussed.
Baumgart, André; Denz, Christof; Bender, Hans-Joachim; Schleppers, Alexander
2009-01-01
The complexity of the operating room (OR) requires that both structural (eg, department layout) and behavioral (eg, staff interactions) patterns of work be considered when developing quality improvement strategies. In our study, we investigated how these contextual factors influence outpatient OR processes and the quality of care delivered. The study setting was a German university-affiliated hospital performing approximately 6000 outpatient surgeries annually. During the 3-year-study period, the hospital significantly changed its outpatient OR facility layout from a decentralized (ie, ORs in adjacent areas of the building) to a centralized (ie, ORs in immediate vicinity of each other) design. To study the impact of the facility change on OR processes, we used a mixed methods approach, including process analysis, process modeling, and social network analysis of staff interactions. The change in facility layout was seen to influence OR processes in ways that could substantially affect patient outcomes. For example, we found a potential for more errors during handovers in the new centralized design due to greater interdependency between tasks and staff. Utilization of the mixed methods approach in our analysis, as compared with that of a single assessment method, enabled a deeper understanding of the OR work context and its influence on outpatient OR processes.
Harris, Tim; McDonald, Keith
2014-12-01
To benchmark walk-in presentations to emergency departments (ED) with those presenting to other local acute healthcare facilities. A large teaching hospital with an annual ED census of 140, 000 adult patients and surrounding associated acute healthcare providers. A random sample of 384 patients who self-presented to the ED was obtained. Benchmarking data were drawn from two general practices; the Tower Hamlets Community Services walk-in centre (co-located on-site with the ED) and the GP-run out-of-hours service. The case-mix presenting to the ED was characterised by a higher proportion of injuries and chest pain, but fewer simple infections and non-traumatic musculoskeletal conditions as compared to other acute care facilities in our region. Patients with injuries and possible cardiac chest pain were more likely to attend the ED, and those with infection or musculoskeletal problems less likely, as compared with other acute healthcare facilities. The population presenting to the ED is distinct from that presenting to general practice, out-of-hours clinics, or walk-in centres. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Xu, Yanping; Randers-Pehrson, Gerhard; Turner, Helen C.; Marino, Stephen A.; Geard, Charles R.; Brenner, David J.; Garty, Guy
2015-01-01
We describe here an accelerator-based neutron irradiation facility, intended to expose blood or small animals to neutron fields mimicking those from an improvised nuclear device at relevant distances from the epicenter. Neutrons are generated by a mixed proton/deuteron beam on a thick beryllium target, generating a broad spectrum of neutron energies that match those estimated for the Hiroshima bomb at 1.5 km from ground zero. This spectrum, dominated by neutron energies between 0.2 and 9 MeV, is significantly different from the standard reactor fission spectrum, as the initial bomb spectrum changes when the neutrons are transported through air. The neutron and gamma dose rates were measured using a custom tissue-equivalent gas ionization chamber and a compensated Geiger-Mueller dosimeter, respectively. Neutron spectra were evaluated by unfolding measurements using a proton-recoil proportional counter and a liquid scintillator detector. As an illustration of the potential use of this facility we present micronucleus yields in single divided, cytokinesis-blocked human peripheral lymphocytes up to 1.5 Gy demonstrating 3- to 5-fold enhancement over equivalent X-ray doses. This facility is currently in routine use, irradiating both mice and human blood samples for evaluation of neutron-specific biodosimetry assays. Future studies will focus on dose reconstruction in realistic mixed neutron/photon fields. PMID:26414507
Xu, Yanping; Randers-Pehrson, Gerhard; Turner, Helen C; Marino, Stephen A; Geard, Charles R; Brenner, David J; Garty, Guy
2015-10-01
We describe here an accelerator-based neutron irradiation facility, intended to expose blood or small animals to neutron fields mimicking those from an improvised nuclear device at relevant distances from the epicenter. Neutrons are generated by a mixed proton/deuteron beam on a thick beryllium target, generating a broad spectrum of neutron energies that match those estimated for the Hiroshima bomb at 1.5 km from ground zero. This spectrum, dominated by neutron energies between 0.2 and 9 MeV, is significantly different from the standard reactor fission spectrum, as the initial bomb spectrum changes when the neutrons are transported through air. The neutron and gamma dose rates were measured using a custom tissue-equivalent gas ionization chamber and a compensated Geiger-Mueller dosimeter, respectively. Neutron spectra were evaluated by unfolding measurements using a proton-recoil proportional counter and a liquid scintillator detector. As an illustration of the potential use of this facility we present micronucleus yields in single divided, cytokinesis-blocked human peripheral lymphocytes up to 1.5 Gy demonstrating 3- to 5-fold enhancement over equivalent X-ray doses. This facility is currently in routine use, irradiating both mice and human blood samples for evaluation of neutron-specific biodosimetry assays. Future studies will focus on dose reconstruction in realistic mixed neutron/photon fields.
Realistic Development and Testing of Fission System at a Non-Nuclear Testing Facility
NASA Technical Reports Server (NTRS)
Godfroy, Tom; VanDyke, Melissa; Dickens, Ricky; Pedersen, Kevin; Lenard, Roger; Houts, Mike
2000-01-01
The use of resistance heaters to simulate heat from fission allows extensive development of fission systems to be performed in non-nuclear test facilities, saving time and money. Resistance heated tests on a module has been performed at the Marshall Space Flight Center in the Propellant Energy Source Testbed (PEST). This paper discusses the experimental facilities and equipment used for performing resistance heated tests. Recommendations are made for improving non-nuclear test facilities and equipment for simulated testing of nuclear systems.
Realistic development and testing of fission systems at a non-nuclear testing facility
NASA Astrophysics Data System (ADS)
Godfroy, Tom; van Dyke, Melissa; Dickens, Ricky; Pedersen, Kevin; Lenard, Roger; Houts, Mike
2000-01-01
The use of resistance heaters to simulate heat from fission allows extensive development of fission systems to be performed in non-nuclear test facilities, saving time and money. Resistance heated tests on a module has been performed at the Marshall Space Flight Center in the Propellant Energy Source Testbed (PEST). This paper discusses the experimental facilities and equipment used for performing resistance heated tests. Recommendations are made for improving non-nuclear test facilities and equipment for simulated testing of nuclear systems. .
Ground Handling of Batteries at Test and Launch-site Facilities
NASA Technical Reports Server (NTRS)
Jeevarajan, Judith A.; Hohl, Alan R.
2008-01-01
Ground handling of flight as well as engineering batteries at test facilities and launch-site facilities is a safety critical process. Test equipment interfacing with the batteries should have the required controls to prevent a hazardous failure of the batteries. Test equipment failures should not induce catastrophic failures on the batteries. Transportation requirements for batteries should also be taken into consideration for safe transportation. This viewgraph presentation includes information on the safe handling of batteries for ground processing at test facilities as well as launch-site facilities.
40 CFR 792.43 - Test system care facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Test system care facilities. 792.43 Section 792.43 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Facilities § 792.43 Test system care facilities...
Facilities | Hydrogen and Fuel Cells | NREL
integration research. Photo of the Hydrogen Infrastructure Testing and Research Facility building, with hydrogen fueling station and fuel cell vehicles. Hydrogen Infrastructure Testing and Research Facility The Hydrogen Infrastructure Testing and Research Facility (HITRF) at the ESIF combines electrolyzers, a
DOE Office of Scientific and Technical Information (OSTI.GOV)
Willoughby III, O.H.; Lukes, G.C.
EnergySolutions, LLC operates its Mixed Waste Facility at Clive, Utah under the provisions of its State-issued Part B Permit. The facility accepts waste that contains both hazardous and radioactive contaminants. Utah is an EPA Agreement State and therefore the Utah Division of Solid and Hazardous Waste (DSHW) is authorized to regulate the hazardous waste operations at the facility. The radioactive portion of the waste is regulated by the Utah Division of Radiation Control. 40 CFR 264.142 outlines the facility requirements for Closure Costs. The owner or operator must have a detailed written estimate of the cost of closing the facilitymore » in accordance with the rules. For many years the State of Utah had relied on the facility's estimate of closure costs as the amount that needed to be funded. This amount is reviewed annually and adjusted for inflation and for changes at the facility. In 2004 the agency and the facility requested bids from independent contractors to provide their estimate for closure costs. Three engineering firms bid on the project. The facility funded the project and both the agency and the facility chose one of the firms to provide an independent estimate. The engineering firms met with both parties and toured the facility. They were also provided with the current closure cost line items. Each firm provided an estimated cost for closure of the facility at the point in the facility's active life that would make the closure most expensive. Included with the direct costs were indirect line items such as overhead, profit, mobilization, hazardous working conditions and regulatory oversight. The agency and the facility reviewed the independent estimates and negotiated a final Closure and Post-Closure Cost Estimate for the Mixed Waste Facility. There are several mechanisms allowed under the rules to fund the Closure and Post- Closure Care Funds. EnergySolutions has chosen to fund their costs through the use of an insurance policy. Changing mechanisms from an irrevocable trust to an insurance policy required extensive review by the DSHW and the Utah Attorney General's Office. The duration of the Post-Closure Care Period is generally designated as 30 years under the hazardous waste rules. The Legislature of the State of Utah commissioned a review of the need for Perpetual Care Funds for hazardous waste facilities. This fund would provide funds for maintenance and monitoring of facilities following termination of the Post-Closure Permit. The DSHW has recommended to the legislature that a perpetual care fund be created. The legislature will study the recommendation and take appropriate action. (authors)« less
The NASA landing gear test airplane
NASA Technical Reports Server (NTRS)
Carter, John F.; Nagy, Christopher J.
1995-01-01
A tire and landing gear test facility has been developed and incorporated into a Convair 990 aircraft. The system can simulate tire vertical load profiles to 250,000 lb, sideslip angles to 15 degrees, and wheel braking on actual runways. Onboard computers control the preprogrammed test profiles through a feedback loop and also record three axis loads, tire slip angle, and tire condition. The aircraft to date has provided tire force and wear data for the Shuttle Orbiter tire on three different runways and at east and west coast landing sites. This report discusses the role of this facility in complementing existing ground tire and landing gear test facilities, and how this facility can simultaneously simulate the vertical load, tire slip, velocity, and surface for an entire aircraft landing. A description is given of the aircraft as well as the test system. An example of a typical test sequence is presented. Data collection and reduction from this facility are discussed, as well as accuracies of calculated parameters. Validation of the facility through ground and flight tests is presented. Tests to date have shown that this facility can operate at remote sites and gather complete data sets of load, slip, and velocity on actual runway surfaces. The ground and flight tests have led to a successful validation of this test facility.
40 CFR 266.345 - Whom must you notify?
Code of Federal Regulations, 2010 CFR
2010-07-01
... FACILITIES Conditional Exemption for Low-Level Mixed Waste Storage, Treatment, Transportation and Disposal....340 prior to disposal in order for the waste to remain exempt under the transportation and disposal...
A hybrid solution approach for a multi-objective closed-loop logistics network under uncertainty
NASA Astrophysics Data System (ADS)
Mehrbod, Mehrdad; Tu, Nan; Miao, Lixin
2015-06-01
The design of closed-loop logistics (forward and reverse logistics) has attracted growing attention with the stringent pressures of customer expectations, environmental concerns and economic factors. This paper considers a multi-product, multi-period and multi-objective closed-loop logistics network model with regard to facility expansion as a facility location-allocation problem, which more closely approximates real-world conditions. A multi-objective mixed integer nonlinear programming formulation is linearized by defining new variables and adding new constraints to the model. By considering the aforementioned model under uncertainty, this paper develops a hybrid solution approach by combining an interactive fuzzy goal programming approach and robust counterpart optimization based on three well-known robust counterpart optimization formulations. Finally, this paper compares the results of the three formulations using different test scenarios and parameter-sensitive analysis in terms of the quality of the final solution, CPU time, the level of conservatism, the degree of closeness to the ideal solution, the degree of balance involved in developing a compromise solution, and satisfaction degree.
Cementitious waste option scoping study report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, A.E.; Taylor, D.D.
1998-02-01
A Settlement Agreement between the Department of Energy (DOE) and the State of Idaho mandates that all high-level radioactive waste (HLW) now stored at the Idaho Chemical Processing Plant (ICPP) on the Idaho National Engineering and Environmental Laboratory (INEEL) will be treated so that it is ready to be moved out of Idaho for disposal by a target date of 2035. This study investigates the nonseparations Cementitious Waste Option (CWO) as a means to achieve this goal. Under this option all liquid sodium-bearing waste (SBW) and existing HLW calcine would be recalcined with sucrose, grouted, canisterized, and interim stored asmore » a mixed-HLW for eventual preparation and shipment off-Site for disposal. The CWO waste would be transported to a Greater Confinement Disposal Facility (GCDF) located in the southwestern desert of the US on the Nevada Test Site (NTS). All transport preparation, shipment, and disposal facility activities are beyond the scope of this study. CWO waste processing, packaging, and interim storage would occur over a 5-year period between 2013 and 2017. Waste transport and disposal would occur during the same time period.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chua, S.E.; Abito, G.F.; Berbano, M.C.
A 1 MWth multi-crop dehydration plant using waste geothermal energy is being operated by the Philippine National Oil Company-Energy Development Corporation (PNOC-EDC) at one of the reinjection pads at the Southern Negros Geothermal Project (SNGP). The facility is composed of two heat exchange systems, seven modular dryers of three different designs, a processing and storage area, a laboratory for quality control tests and an office for general administration and other services. Products from the plant include copra (dried coconut meat), dried fruits, fish and squid, and other agricultural products. Pilot demonstration runs showed the techno-economic: viability of the drying plant.more » Calculated IRR for production of copra and fruits is 19.3 %, giving a payback period on capital investment of 4.2 years. Sustainability of the operation of the plant requires detailed logistical, production, and marketing plans for the assumed production mix. The facility, which is from a grant from the United Nations Development Programme, is proposed to be {open_quotes}turned over{close_quotes} to a PNOC-formed consortium of farmers cooperatives and associations for its continuous operation and management as a profitable business venture for the community.« less
Schumacher, Loni L; Huss, Anne R; Cochrane, Roger A; Stark, Charles R; Woodworth, Jason C; Bai, Jianfa; Poulsen, Elizabeth G; Chen, Qi; Main, Rodger G; Zhang, Jianqiang; Gauger, Phillip C; Ramirez, Alejandro; Derscheid, Rachel J; Magstadt, Drew M; Dritz, Steve S; Jones, Cassandra K
2017-01-01
New regulatory and consumer demands highlight the importance of animal feed as a part of our national food safety system. Porcine epidemic diarrhea virus (PEDV) is the first viral pathogen confirmed to be widely transmissible in animal food. Because the potential for viral contamination in animal food is not well characterized, the objectives of this study were to 1) observe the magnitude of virus contamination in an animal food manufacturing facility, and 2) investigate a proposed method, feed sequencing, to decrease virus decontamination on animal food-contact surfaces. A U.S. virulent PEDV isolate was used to inoculate 50 kg swine feed, which was mixed, conveyed, and discharged into bags using pilot-scale feed manufacturing equipment. Surfaces were swabbed and analyzed for the presence of PEDV RNA by quantitative real-time polymerase chain reaction (qPCR). Environmental swabs indicated complete contamination of animal food-contact surfaces (0/40 vs. 48/48, positive baseline samples/total baseline samples, positive subsequent samples/total subsequent samples, respectively; P < 0.05) and near complete contamination of non-animal food-contact surfaces (0/24 vs. 16/18, positive baseline samples/total baseline samples, positive subsequent samples/total subsequent samples, respectively; P < 0.05). Flushing animal food-contact surfaces with low-risk feed is commonly used to reduce cross-contamination in animal feed manufacturing. Thus, four subsequent 50 kg batches of virus-free swine feed were manufactured using the same system to test its impact on decontaminating animal food-contact surfaces. Even after 4 subsequent sequences, animal food-contact surfaces retained viral RNA (28/33 positive samples/total samples), with conveying system being more contaminated than the mixer. A bioassay to test infectivity of dust from animal food-contact surfaces failed to produce infectivity. This study demonstrates the potential widespread viral contamination of surfaces in an animal food manufacturing facility and the difficulty of removing contamination using conventional feed sequencing, which underscores the importance for preventing viruses from entering and contaminating such facilities.
Oladele, Edward Adekola; Khamofu, Hadiza; Asala, Seun; Saleh, Mariya; Ralph-Opara, Uche; Nwosisi, Charles; Anyaike, Chukwuma; Gana, Catherine; Adedokun, Oluwasanmi; Dirks, Rebecca; Adebayo, Olufunsho; Oduwole, Modupe; Mandala, Justin; Torpey, Kwasi
2017-01-01
As the world is making progress towards elimination of mother-to-child transmission of HIV, poor coverage of PMTCT services in Nigeria remains a major challenge. In order to address this, scale-up was planned with activities organized into 3 phases. This paper describes the process undertaken in eight high burden Nigerian states to rapidly close PMTCT coverage gaps at facility and population levels between February 2013 and March 2014. Activities were grouped into three phases-pre-assessment phase (engagement of a wide range of stakeholders), assessment (rapid health facility assessment, a cross sectional survey using mixed methods conducted in the various states between Feb and May 2013 and impact modelling), and post-assessment (drawing up costed state operational plans to achieve eMTCT by 2015, data-driven smart scale-up). Over a period of 10 months starting June 2013, 2044 facilities were supported to begin provision of PMTCT services. This increased facility coverage from 8% to 50%. A 246% increase was also recorded in the number of pregnant women and their families who have access to HIV testing and counselling in the context of PMTCT. Similarly, access to antiretrovirals for PMTCT has witnessed a 152% increase in these eight states between October 2013 and October 2014. A data-driven and participatory approach can be used to rapidly scale-up PMTCT services at community and facility levels in this region. These results present us with hope for real progress in Nigeria. We are confident that the efforts described here will contribute significantly to eliminating new pediatric HIV infection in Nigeria.
NASA Astrophysics Data System (ADS)
Mohai, Paul; Saha, Robin
2015-11-01
Although a large body of quantitative environmental justice research exists, only a handful of studies have examined the processes by which racial and socioeconomic disparities in the location of polluting industrial facilities can occur. These studies have had mixed results, we contend, principally because of methodological differences, that is, the use of the unit-hazard coincidence method as compared to distance-based methods. This study is the first national-level environmental justice study to conduct longitudinal analyses using distance-based methods. Our purposes are to: (1) determine whether disparate siting, post-siting demographic change, or a combination of the two created present-day disparities; (2) test related explanations; and (3) determine whether the application of distance-based methods helps resolve the inconsistent findings of previous research. We used a national database of commercial hazardous waste facilities sited from 1966 to 1995 and examined the demographic composition of host neighborhoods around the time of siting and demographic changes that occurred after siting. We found strong evidence of disparate siting for facilities sited in all time periods. Although we found some evidence of post-siting demographic changes, they were mostly a continuation of changes that occurred in the decade or two prior to siting, suggesting that neighborhood transition serves to attract noxious facilities rather than the facilities themselves attracting people of color and low income populations. Our findings help resolve inconsistencies among the longitudinal studies and builds on the evidence from other subnational studies that used distance-based methods. We conclude that racial discrimination and sociopolitical explanations (i.e., the proposition that siting decisions follow the ‘path of least resistance’) best explain present-day inequities.
Evaluation of flood preparedness in government healthcare facilities in Eastern Province, Sri Lanka.
Farley, Jessica M; Suraweera, Inoka; Perera, W L S P; Hess, Jeremy; Ebi, Kristie L
2017-01-01
Sri Lanka is vulnerable to floods and other hydro-meteorological disasters. Climate change is projected to increase the intensity of these events. This study aimed to assess the flood preparedness in healthcare facilities in Eastern Province. This was a cross-sectional, descriptive, mixed methods study conducted in Trincomalee District. Surveys were conducted in 31 government healthcare facilities, using a pre-tested, structured questionnaire covering the last 5 years. Seven in-depth interviews were conducted with randomly selected Medical Officers in Charge or their equivalent, and 3 interviews were conducted with Medical Offices of Health. Two general hospitals, 3 base hospitals, 11 divisional hospitals, and 15 primary care units were included. Six respondents (19.4%) reported flooding in their facility, and 19 (61.3%) reported flooding in their catchment area. For the health workforce, 77.4% of respondents reported not enough staff to perform normal service delivery during disasters, and 25.5% reported staff absenteeism due to flooding. Several respondents expressed a desire for more disaster-specific and general clinical training opportunities for themselves and their staff. Most respondents (80.7%) reported no delays in supply procurement during weather emergencies, but 61.3% reported insufficient supplies to maintain normal service delivery during disasters. Four facilities (12.9%) had disaster preparedness plans, and 4 (12.9%) had any staff trained on disaster preparedness or management within the last year. One quarter (25.8%) of respondents had received any written guidance on disaster preparedness from the regional, provincial, or national level in the last year. While there is a strong health system operating in Sri Lanka, improvements are needed in localized and appropriate disaster-related training, resources for continuing clinical education, and investments in workforce to strengthen flood and other disaster resilience within the government healthcare system in the study district.
Mobile Versus Fixed Facility: Latinas' Attitudes and Preferences for Obtaining a Mammogram.
Scheel, John R; Tillack, Allison A; Mercer, Lauren; Coronado, Gloria D; Beresford, Shirley A A; Molina, Yamile; Thompson, Beti
2018-01-01
Mobile mammographic services have been proposed as a way to reduce Latinas' disproportionate late-stage presentation compared with white women by increasing their access to mammography. The aims of this study were to assess why Latinas may not use mobile mammographic services and to explore their preferences after using these services. Using a mixed-methods approach, a secondary analysis was conducted of baseline survey data (n = 538) from a randomized controlled trial to improve screening mammography rates among Latinas in Washington. Descriptive statistics and bivariate regression were used to characterize mammography location preferences and to test for associations with sociodemographic indices, health care access, and perceived breast cancer risk and beliefs. On the basis of these findings, a qualitative study (n = 18) was used to explore changes in perceptions after using mobile mammographic services. More Latinas preferred obtaining a mammogram at a fixed facility (52.3% [n = 276]) compared with having no preference (46.3% [n = 249]) and preferring mobile mammographic services (1.7% [n = 9]). Concerns about privacy and comfort (15.6% [n = 84]) and about general quality (10.6% [n = 57]) were common reasons for preferring a fixed facility. Those with no history of mammography preferred a fixed facility (P < .05). In the qualitative study, Latinas expressed similar initial concerns but became positive toward the mobile mammographic services after obtaining a mammogram. Although most Latinas preferred obtaining a mammogram at a fixed facility, positive experiences with mobile mammography services changed their attitudes toward them. These findings highlight the need to include community education when using mobile mammographic service to increase screening mammography rates in underserved communities. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Results of Hg speciation testing on DWPF SMECT-8, OGCT-1, AND OGCT-2 samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bannochie, C.
2016-02-22
The Savannah River National Laboratory (SRNL) was tasked with preparing and shipping samples for Hg speciation by Eurofins Frontier Global Sciences, Inc. in Seattle, WA on behalf of the Savannah River Remediation (SRR) Mercury Task Team. The sixteenth shipment of samples was designated to include a Defense Waste Processing Facility (DWPF) Slurry Mix Evaporator Condensate Tank (SMECT) sample from Sludge Receipt and Adjustment Tank (SRAT) Batch 738 processing and two Off-Gas Condensate Tank (OGCT) samples, one following Batch 736 and one following Batch 738. The DWPF sample designations for the three samples analyzed are provided. The Batch 738 ‘End ofmore » SME Cycle’ SMECT sample was taken at the conclusion of Slurry Mix Evaporator (SME) operations for this batch and represents the fourth SMECT sample examined from Batch 738. Batch 738 experienced a sludge slurry carryover event, which introduced sludge solids to the SMECT that were particularly evident in the SMECT-5 sample, but less evident in the ‘End of SME Cycle’ SMECT-8 sample.« less
A Comparison of the Viscosities of Thickened Liquids for Pediatric Dysphagia.
NASA Astrophysics Data System (ADS)
Wijesinghe, Ranjith; Clifton, Mekale; Tarlton, Morgan; Heinsohn, Erica; Ewing, Mary
It has been reported that Speech Language Pathologists in different facilities across the nation use a variety of thickening agents and recipes as therapeutic measures for infants and children diagnosed with dysphagia. Limited research has been completed in this area. Viscosity was tested to determine the thickness of each thickening agent mixed with infant formula. The values were then compared to the National Dysphagia Diet liquid levels to determine which thickening agent resulted in the desired viscosity levels. The thickeners were mixed with common infant formulas and soy formulas to determine if the type of formula impacted the viscosity. The main goal was to determine if the assumed thickness level (viscosity) of prescribed thickened liquids was actually being met. This topic is of high concern because of its impact on the safety and well-being of clients with dysphagia. A viscometer was used to collect the viscosity levels. Commercially available formulas selected for this study. The final results of our investigation will be presented during the APS meeting. This work is supported by a Ball State University Immersive Learning Grant.
38. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF TEST ...
38. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF TEST BAY AND EXHAUST PIT, LOOKING WEST - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM
37. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF TEST ...
37. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF TEST BAY AND EXHAUST PIT, LOOKING SOUTHWEST - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM
Material Processing Facility - Skylab Experiment M512
NASA Technical Reports Server (NTRS)
1972-01-01
This chart details Skylab's Materials Processing Facility experiment (M512). This facility, located in the Multiple Docking Adapter, was developed for Skylab and accommodated 14 different experiments that were carried out during the three marned missions. The abilities to melt and mix without the contaminating effects of containers, to suppress thermal convection and buoyancy in fluids, and to take advantage of electrostatic and magnetic forces and otherwise masked by gravitation opened the way to new knowledge of material properties and processes. This beginning would ultimately lead to the production of valuable new materials for use on Earth.
Brown, Scott C; Wang, Kefeng; Dong, Chuanhui; Farrell, Mary Beth; Heller, Gary V; Gornik, Heather L; Hutchisson, Marge; Needleman, Laurence; Benenati, James F; Jaff, Michael R; Meier, George H; Perese, Susana; Bendick, Phillip; Hamburg, Naomi M; Lohr, Joann M; LaPerna, Lucy; Leers, Steven A; Lilly, Michael P; Tegeler, Charles; Katanick, Sandra L; Alexandrov, Andrei V; Siddiqui, Adnan H; Rundek, Tatjana
2016-09-01
Accreditation of cerebrovascular ultrasound laboratories by the Intersocietal Accreditation Commission (IAC) and equivalent organizations is supported by the Joint Commission certification of stroke centers. Limited information exists on the accreditation status and geographic distribution of cerebrovascular testing facilities in the United States. Our study objectives were to identify the proportion of IAC-accredited outpatient cerebrovascular testing facilities used by Medicare beneficiaries, describe their geographic distribution, and identify variations in cerebrovascular testing procedure types and volumes by accreditation status. As part of the VALUE (Vascular Accreditation, Location, and Utilization Evaluation) Study, we examined the proportion of IAC-accredited facilities that conducted cerebrovascular testing in a 5% Centers for Medicare and Medicaid Services random Outpatient Limited Data Set in 2011 and investigated their geographic distribution using geocoding. Among 7327 outpatient facilities billing Medicare for cerebrovascular testing, only 22% (1640) were IAC accredited. The proportion of IAC-accredited cerebrovascular testing facilities varied by region (χ(2)[3] = 177.1; P < .0001), with 29%, 15%, 13%, and 10% located in the Northeast, South, Midwest, and West, respectively. However, of the total number of cerebrovascular outpatient procedures conducted in 2011 (38,555), 40% (15,410) were conducted in IAC-accredited facilities. Most cerebrovascular testing procedures were carotid duplex, with 40% of them conducted in IAC-accredited facilities. The proportion of facilities conducting outpatient cerebrovascular testing accredited by the IAC is low and varies by region. The growing number of certified stroke centers should be accompanied by more accredited outpatient vascular testing facilities, which could potentially improve the quality of stroke care.
Ir, Por; Korachais, Catherine; Chheng, Kannarath; Horemans, Dirk; Van Damme, Wim; Meessen, Bruno
2015-08-15
Increasing the coverage of skilled attendance at births in a health facility (facility delivery) is crucial for saving the lives of mothers and achieving Millennium Development Goal five. Cambodia has significantly increased the coverage of facility deliveries and reduced the maternal mortality ratio in the last decade. The introduction of a nationwide government implemented and funded results-based financing initiative, known as the Government Midwifery Incentive Scheme (GMIS), is considered one of the most important contributors to this. We evaluated GMIS to explore its effects on facility deliveries and the health system. We used a mixed-methods design. An interrupted time series model was applied, using routine longitudinal data on reported deliveries between 2006 and 2011 that were extracted from the health information system. In addition, we interviewed 56 key informants and performed 12 focus group discussions with 124 women who had given birth (once or more) since 2006. Findings from the quantitative data were carefully interpreted and triangulated with those from qualitative data. We found that facility deliveries have tripled from 19% of the estimated number of births in 2006 to 57% in 2011 and this increase was more substantial at health centres as compared to hospitals. Segmented linear regressions showed that the introduction of GMIS in October 2007 made the increase in facility deliveries and deliveries with skilled attendants significantly jump by 18 and 10% respectively. Results from qualitative data also suggest that the introduction of GMIS together with other interventions that aimed to improve access to essential maternal health services led to considerable improvements in public health facilities and a steep increase in facility deliveries. Home deliveries attended by traditional birth attendants decreased concomitantly. We also outline several operational issues and limitations of GMIS. The available evidence strongly suggests that GMIS is an effective mechanism to complement other interventions to improve health system performance and boost facility deliveries as well as skilled birth attendance; thereby contributing to the reduction of maternal mortality. Our findings provide useful lessons for Cambodia to further improve GMIS and for other low-income countries to implement similar results-based financing mechanisms.
Esmedere Eren, Sevim; Karakukcu, Cigdem; Ciraci, Mehmet Z; Ustundag, Yasemin; Karakukcu, Musa
2018-06-01
: The mixing test is used to evaluate whether prolonged activated partial thromboplastin time (APTT) is due to an inhibitor or a factor deficiency. The coagulation reaction is demonstrated with APTT derivative curves on the ACL TOP series. We aimed to determine the utility of APTT derivative curves in the mixing test process. The plasma of a patient was mixed with normal plasma in a 1 : 1 ratio and APTT assay was performed with SynthASil reagent. We observed roughness, biphasic and shoulder patterns in derivative curves during the mixing test. An extended laboratory investigation revealed a positive lupus anticoagulant, low factors XI and IX activities. Along with mixing test cut-off limits, we recommend analysing changes in APTT derivative curves to minimize erroneous interpretations of the mixing test. Derivative curves display either a normalizing pattern in factor deficiencies or an atypical pattern in the presence of lupus anticoagulant.
Nuclear electric propulsion development and qualification facilities
NASA Technical Reports Server (NTRS)
Dutt, D. S.; Thomassen, K.; Sovey, J.; Fontana, Mario
1991-01-01
This paper summarizes the findings of a Tri-Agency panel consisting of members from the National Aeronautics and Space Administration (NASA), U.S. Department of Energy (DOE), and U.S. Department of Defense (DOD) that were charged with reviewing the status and availability of facilities to test components and subsystems for megawatt-class nuclear electric propulsion (NEP) systems. The facilities required to support development of NEP are available in NASA centers, DOE laboratories, and industry. However, several key facilities require significant and near-term modification in order to perform the testing required to meet a 2014 launch date. For the higher powered Mars cargo and piloted missions, the priority established for facility preparation is: (1) a thruster developmental testing facility, (2) a thruster lifetime testing facility, (3) a dynamic energy conversion development and demonstration facility, and (4) an advanced reactor testing facility (if required to demonstrate an advanced multiwatt power system). Facilities to support development of the power conditioning and heat rejection subsystems are available in industry, federal laboratories, and universities. In addition to the development facilities, a new preflight qualifications and acceptance testing facility will be required to support the deployment of NEP systems for precursor, cargo, or piloted Mars missions. Because the deployment strategy for NEP involves early demonstration missions, the demonstration of the SP-100 power system is needed by the early 2000's.
Characteristics of HIV Care and Treatment in PEPFAR-Supported Sites
Filler, Scott; Berruti, Andres A.; Menzies, Nick; Berzon, Rick; Ellerbrock, Tedd V.; Ferris, Robert; Blandford, John M.
2011-01-01
Background The U.S. President’s Emergency Plan for AIDS Relief (PEPFAR) has supported the extension of HIV care and treatment to 2.4 million individuals by September 2009. With increasing resources targeted toward scale-up, it is important to understand the characteristics of current PEPFAR-supported HIV care and treatment sites. Methods Forty-five sites in Botswana, Ethiopia, Nigeria, Uganda, and Vietnam were sampled. Data were collected retrospectively from successive 6-month periods of site operations, through reviews of facility records and interviews with site personnel between April 2006 and March 2007. Facility size and scale-up rate, patient characteristics, staffing models, clinical and laboratory monitoring, and intervention mix were compared. Results Sites added a median of 293 patients per quarter. By the evaluation’s end, sites supported a median of 1,649 HIV patients, 922 of them receiving antiretroviral therapy (ART). Patients were predominantly adult (97.4%) and the majority (96.5%) were receiving regimens based on nonnucleoside reverse transcriptase inhibitors (NNRTIs). The ratios of physicians to patients dropped substantially as sites matured. ART patients were commonly seen monthly or quarterly for clinical and laboratory monitoring, with CD4 counts being taken at 6-month intervals. One-third of sites provided viral load testing. Cotrimoxazole prophylaxis was the most prevalent supportive service. Conclusions HIV treatment sites scaled up rapidly with the influx of resources and technical support through PEPFAR, providing complex health services to progressively expanding patient cohorts. Human resources are stretched thin, and delivery models and intervention mix differ widely between sites. Ongoing research is needed to identify best-practice service delivery models. PMID:21346585
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reigel, M.; Johnson, F.; Crawford, C.
2011-09-20
The U.S. Department of Energy (DOE), Office of River Protection (ORP), is responsible for the remediation and stabilization of the Hanford Site tank farms, including 53 million gallons of highly radioactive mixed wasted waste contained in 177 underground tanks. The plan calls for all waste retrieved from the tanks to be transferred to the Waste Treatment Plant (WTP). The WTP will consist of three primary facilities including pretreatment facilities for Low Activity Waste (LAW) to remove aluminum, chromium and other solids and radioisotopes that are undesirable in the High Level Waste (HLW) stream. Removal of aluminum from HLW sludge canmore » be accomplished through continuous sludge leaching of the aluminum from the HLW sludge as sodium aluminate; however, this process will introduce a significant amount of sodium hydroxide into the waste stream and consequently will increase the volume of waste to be dispositioned. A sodium recovery process is needed to remove the sodium hydroxide and recycle it back to the aluminum dissolution process. The resulting LAW waste stream has a high concentration of aluminum and sodium and will require alternative immobilization methods. Five waste forms were evaluated for immobilization of LAW at Hanford after the sodium recovery process. The waste forms considered for these two waste streams include low temperature processes (Saltstone/Cast stone and geopolymers), intermediate temperature processes (steam reforming and phosphate glasses) and high temperature processes (vitrification). These immobilization methods and the waste forms produced were evaluated for (1) compliance with the Performance Assessment (PA) requirements for disposal at the IDF, (2) waste form volume (waste loading), and (3) compatibility with the tank farms and systems. The iron phosphate glasses tested using the product consistency test had normalized release rates lower than the waste form requirements although the CCC glasses had higher release rates than the quenched glasses. However, the waste form failed to meet the vapor hydration test criteria listed in the WTP contract. In addition, the waste loading in the phosphate glasses were not as high as other candidate waste forms. Vitrification of HLW waste as borosilicate glass is a proven process; however the HLW and LAW streams at Hanford can vary significantly from waste currently being immobilized. The ccc glasses show lower release rates for B and Na than the quenched glasses and all glasses meet the acceptance criterion of < 4 g/L. Glass samples spiked with Re{sub 2}O{sub 7} also passed the PCT test. However, further vapor hydration testing must be performed since all the samples cracked and the test could not be performed. The waste loading of the iron phosphate and borosilicate glasses are approximately 20 and 25% respectively. The steam reforming process produced the predicted waste form for both the high and low aluminate waste streams. The predicted waste loadings for the monolithic samples is approximately 39%, which is higher than the glass waste forms; however, at the time of this report, no monolithic samples were made and therefore compliance with the PA cannot be determined. The waste loading in the geopolymer is approximately 40% but can vary with the sodium hydroxide content in the waste stream. Initial geopolymer mixes revealed compressive strengths that are greater than 500 psi for the low aluminate mixes and less than 500 psi for the high aluminate mixes. Further work testing needs to be performed to formulate a geopolymer waste form made using a high aluminate salt solution. A cementitious waste form has the advantage that the process is performed at ambient conditions and is a proven process currently in use for LAW disposal. The Saltstone/Cast Stone formulated using low and high aluminate salt solutions retained at least 97% of the Re that was added to the mix as a dopant. While this data is promising, additional leaching testing must be performed to show compliance with the PA. Compressive strength tests must also be performed on the Cast Stone monoliths to verify PA compliance. Based on testing performed for this report, the borosilicate glass and Cast Stone are the recommended waste forms for further testing. Both are proven technologies for radioactive waste disposal and the initial testing using simulated Hanford LAW waste shows compliance with the PA. Both are resistant to leaching and have greater than 25% waste loading.« less
NASA Technical Reports Server (NTRS)
Mcquillen, John; Brown, Dan; Hussey, Sam; Zoldak, John
2014-01-01
The Intravenous Fluid Generation (IVGEN) Experiment was a technology demonstration experiment that purified ISS potable water, mixed it with salt, and transferred it through a sterilizing filter. On-orbit performance was verified as appropriate and two 1.5 l bags of normal saline solution were returned to earth for post-flight testing by a FDA certified laboratory for compliance with United States Pharmacopiea (USP) standards. Salt concentration deviated from required values and an analysis identified probable causes. Current efforts are focused on Total Organic Content (TOC) testing, and shelf life.The Intravenous Fluid Generation (IVGEN) Experiment demonstrated the purification of ISS potable water, the mixing of the purified water with sodium chloride, and sterilization of the solution via membrane filtration. On-orbit performance was monitored where feasible and two 1.5-liter bags of normal saline solution were returned to earth for post-flight testing by a FDA-registered laboratory for compliance with United States Pharmacopeia (USP)standards [1]. Current efforts have been focused on challenge testing with identified [2] impurities (total organic-carbon), and shelf life testing. The challenge testing flowed known concentrations of contaminants through the IVGEN deionizing cartridge and membrane filters to test their effectiveness. One finding was that the filters and DI-resin themselves contribute to the contaminant load during initial startup, suggesting that the first 100 ml of fluid be discarded. Shelf life testing is ongoing and involves periodic testing of stored DI cartridges and membrane filters that are capped and sealed in hermetic packages. The testing is conducted at six month intervals measuring conductivity and endotoxins in the effluent. Currently, the packaging technique has been successfully demonstrated for one year of storage testing. The USP standards specifies that the TOC be conducted at point of generation as opposed to point of consumption. Samples were generated and shipped to an FDA facility however, testing determined that the samples failed the TOC specification with most likely due to leaching from the sample container. Shelf life testing is examining packaging techniques and periodic testing of samples of DI cartridges that are capped and sealed in hermetic packages. Periodic testing of the purified water output will be conducted at six month intervals.
40 CFR 437.40 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... portion of wastewater discharges from a centralized waste treatment facility that results from mixing any... standards) and establishes that it provides equivalent treatment as defined in § 437.2(h). (b) In order to...
Coupled Facility/Payload Vibration Modeling Improvements
NASA Technical Reports Server (NTRS)
Carnahan, Timothy M.; Kaiser, Michael
2015-01-01
A major phase of aerospace hardware verification is vibration testing. The standard approach for such testing is to use a shaker to induce loads into the payload. In preparation for vibration testing at NASA/GSFC there is an analysis to assess the responses of the payload. A new method of modeling the test is presented that takes into account dynamic interactions between the facility and the payload. This dynamic interaction has affected testing in the past, but been ignored or adjusted for during testing. By modeling the combination of the facility and test article (payload) it is possible to improve the prediction of hardware responses. Many aerospace test facilities work in similar way to those at NASA Goddard Space Flight Center. Lessons learned here should be applicable to other test facilities with similar setups.
An inventory of aeronautical ground research facilities. Volume 3: Structural
NASA Technical Reports Server (NTRS)
Pirrello, C. J.; Hardin, R. D.; Heckart, M. V.; Brown, K. R.
1971-01-01
An inventory of test facilities for conducting acceleration, environmental, impact, structural shock, load, heat, vibration, and noise tests is presented. The facility is identified with a description of the equipment, the testing capabilities, and cost of operation. Performance data for the facility are presented in charts and tables.
46 CFR 162.050-15 - Designation of facilities.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... This is the mean and standard deviation, respectively, of the differences between the known sample... sample analysis, and the materials necessary to perform the tests; (2) Each facility test rig must be of... facilities. (a) Each request for designation as a facility authorized to perform approval tests must be...
40 CFR 792.43 - Test system care facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... (a) A testing facility shall have a sufficient number of animal rooms or other test system areas, as... accomplished within a room or area by housing them separately in different chambers or aquaria. Separation of... different tests. (b) A testing facility shall have a number of animal rooms or other test system areas...
40 CFR 792.43 - Test system care facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... (a) A testing facility shall have a sufficient number of animal rooms or other test system areas, as... accomplished within a room or area by housing them separately in different chambers or aquaria. Separation of... different tests. (b) A testing facility shall have a number of animal rooms or other test system areas...
40 CFR 792.43 - Test system care facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... (a) A testing facility shall have a sufficient number of animal rooms or other test system areas, as... accomplished within a room or area by housing them separately in different chambers or aquaria. Separation of... different tests. (b) A testing facility shall have a number of animal rooms or other test system areas...
Calibration of the NASA Glenn 8- by 6-Foot Supersonic Wind Tunnel (1996 and 1997 Tests)
NASA Technical Reports Server (NTRS)
Arrington, E. Allen
2012-01-01
There were several physical and operational changes made to the NASA Glenn Research Center 8- by 6-Foot Supersonic Wind Tunnel during the period of 1992 through 1996. Following each of these changes, a facility calibration was conducted to provide the required information to support the research test programs. Due to several factors (facility research test schedule, facility downtime and continued facility upgrades), a full test section calibration was not conducted until 1996. This calibration test incorporated all test section configurations and covered the existing operating range of the facility. However, near the end of that test entry, two of the vortex generators mounted on the compressor exit tailcone failed causing minor damage to the honeycomb flow straightener. The vortex generators were removed from the facility and calibration testing was terminated. A follow-up test entry was conducted in 1997 in order to fully calibrate the facility without the effects of the vortex generators and to provide a complete calibration of the newly expanded low speed operating range. During the 1997 tunnel entry, all planned test points required for a complete test section calibration were obtained. This data set included detailed in-plane and axial flow field distributions for use in quantifying the test section flow quality.
Biogasification of community-derived biomass and solid wastes in a pilot-scale SOLCON reactor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Srivastava, V.J.; Biljetina, R.; Isaacson, H.R.
1988-01-01
The Institute of Gas Technology has developed a novel, solids- concentrating (SOLCON) bioreactor to convert a variety of individual or mixed feedstocks (biomass and wastes) to methane at higher rates and efficiencies than those obtained from conventional high-rate anaerobic digesters. The biogasification studies are being conducted in a pilot-scale experimental test unit (ETU) located in the Walt Disney World Resort Complex, Orlando, Florida. This paper describes the ETU facility, the logistics of feedstock integration, the SOLCON reactor design and operating techniques, and the results obtained during 4 years of stable, uninterrupted operation with different feedstocks. The SOLCON reactor consistently outperformedmore » the conventional stirred-tank reactor by 20% to 50%.« less
NASA Astrophysics Data System (ADS)
Banica, M. C.; Chun, J.; Scheuermann, T.; Weigand, B.; Wolfersdorf, J. v.
2009-01-01
Scramjet powered vehicles can decrease costs for access to space but substantial obstacles still exist in their realization. For example, experiments in the relevant Mach number regime are difficult to perform and flight testing is expensive. Therefore, numerical methods are often employed for system layout but they require validation against experimental data. Here, we validate the commercial code CFD++ against experimental results for hydrogen combustion in the supersonic combustion facility of the Institute of Aerospace Thermodynamics (ITLR) at the Universität Stuttgart. Fuel is injected through a lobed a strut injector, which provides rapid mixing. Our numerical data shows reasonable agreement with experiments. We further investigate effects of varying equivalence ratios on several important performance parameters.
Engine component instrumentation development facility at NASA Lewis Research Center
NASA Technical Reports Server (NTRS)
Bruckner, Robert J.; Buggele, Alvin E.; Lepicovsky, Jan
1992-01-01
The Engine Components Instrumentation Development Facility at NASA Lewis is a unique aeronautics facility dedicated to the development of innovative instrumentation for turbine engine component testing. Containing two separate wind tunnels, the facility is capable of simulating many flow conditions found in most turbine engine components. This facility's broad range of capabilities as well as its versatility provide an excellent location for the development of novel testing techniques. These capabilities thus allow a more efficient use of larger and more complex engine component test facilities.
Combined analysis of modeled and monitored SO2 concentrations at a complex smelting facility.
Rehbein, Peter J G; Kennedy, Michael G; Cotsman, David J; Campeau, Madonna A; Greenfield, Monika M; Annett, Melissa A; Lepage, Mike F
2014-03-01
Vale Canada Limited owns and operates a large nickel smelting facility located in Sudbury, Ontario. This is a complex facility with many sources of SO2 emissions, including a mix of source types ranging from passive building roof vents to North America's tallest stack. In addition, as this facility performs batch operations, there is significant variability in the emission rates depending on the operations that are occurring. Although SO2 emission rates for many of the sources have been measured by source testing, the reliability of these emission rates has not been tested from a dispersion modeling perspective. This facility is a significant source of SO2 in the local region, making it critical that when modeling the emissions from this facility for regulatory or other purposes, that the resulting concentrations are representative of what would actually be measured or otherwise observed. To assess the accuracy of the modeling, a detailed analysis of modeled and monitored data for SO2 at the facility was performed. A mobile SO2 monitor sampled at five locations downwind of different source groups for different wind directions resulting in a total of 168 hr of valid data that could be used for the modeled to monitored results comparison. The facility was modeled in AERMOD (American Meteorological Society/U.S. Environmental Protection Agency Regulatory Model) using site-specific meteorological data such that the modeled periods coincided with the same times as the monitored events. In addition, great effort was invested into estimating the actual SO2 emission rates that would likely be occurring during each of the monitoring events. SO2 concentrations were modeled for receptors around each monitoring location so that the modeled data could be directly compared with the monitored data. The modeled and monitored concentrations were compared and showed that there were no systematic biases in the modeled concentrations. This paper is a case study of a Combined Analysis of Modelled and Monitored Data (CAMM), which is an approach promulgated within air quality regulations in the Province of Ontario, Canada. Although combining dispersion models and monitoring data to estimate or refine estimates of source emission rates is not a new technique, this study shows how, with a high degree of rigor in the design of the monitoring and filtering of the data, it can be applied to a large industrial facility, with a variety of emission sources. The comparison of modeled and monitored SO2 concentrations in this case study also provides an illustration of the AERMOD model performance for a large industrial complex with many sources, at short time scales in comparison with monitored data. Overall, this analysis demonstrated that the AERMOD model performed well.
Design philosophy of the Jet Propulsion Laboratory infrared detector test facility
NASA Technical Reports Server (NTRS)
Burns, R.; Blessinger, M. A.
1983-01-01
To support the development of advanced infrared remote sensing instrumentation using line and area arrays, a test facility has been developed to characterize the detectors. The necessary performance characteristics of the facility were defined by considering current and projected requirements for detector testing. The completed facility provides the desired level of detector testing capability as well as providing ease of human interaction.