Sample records for ml flow em

  1. Quantitative analysis of aortic regurgitation: real-time 3-dimensional and 2-dimensional color Doppler echocardiographic method--a clinical and a chronic animal study

    NASA Technical Reports Server (NTRS)

    Shiota, Takahiro; Jones, Michael; Tsujino, Hiroyuki; Qin, Jian Xin; Zetts, Arthur D.; Greenberg, Neil L.; Cardon, Lisa A.; Panza, Julio A.; Thomas, James D.

    2002-01-01

    BACKGROUND: For evaluating patients with aortic regurgitation (AR), regurgitant volumes, left ventricular (LV) stroke volumes (SV), and absolute LV volumes are valuable indices. AIM: The aim of this study was to validate the combination of real-time 3-dimensional echocardiography (3DE) and semiautomated digital color Doppler cardiac flow measurement (ACM) for quantifying absolute LV volumes, LVSV, and AR volumes using an animal model of chronic AR and to investigate its clinical applicability. METHODS: In 8 sheep, a total of 26 hemodynamic states were obtained pharmacologically 20 weeks after the aortic valve noncoronary (n = 4) or right coronary (n = 4) leaflet was incised to produce AR. Reference standard LVSV and AR volume were determined using the electromagnetic flow method (EM). Simultaneous epicardial real-time 3DE studies were performed to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV), and LVSV by subtracting LVESV from LVEDV. Simultaneous ACM was performed to obtain LVSV and transmitral flows; AR volume was calculated by subtracting transmitral flow volume from LVSV. In a total of 19 patients with AR, real-time 3DE and ACM were used to obtain LVSVs and these were compared with each other. RESULTS: A strong relationship was found between LVSV derived from EM and those from the real-time 3DE (r = 0.93, P <.001, mean difference (3D - EM) = -1.0 +/- 9.8 mL). A good relationship between LVSV and AR volumes derived from EM and those by ACM was found (r = 0.88, P <.001). A good relationship between LVSV derived from real-time 3DE and that from ACM was observed (r = 0.73, P <.01, mean difference = 2.5 +/- 7.9 mL). In patients, a good relationship between LVSV obtained by real-time 3DE and ACM was found (r = 0.90, P <.001, mean difference = 0.6 +/- 9.8 mL). CONCLUSION: The combination of ACM and real-time 3DE for quantifying LV volumes, LVSV, and AR volumes was validated by the chronic animal study and was shown to be clinically applicable.

  2. Staff - Cheryl E. Cameron | Alaska Division of Geological & Geophysical

    Science.gov Websites

    Geothermal Research, v. 264, p. 85-106. http://dx.doi.org/10.1016/j.jvolgeores.2013.07.003 Coombs, M.L p. http://dggs.alaska.gov/pubs/id/23555 Larsen, J.F., Nye, C.J., Coombs, M.L., Tilman, Mariah Volcano, chapter 15, in Power, J.A., Coombs, M.L., and Freymueller, J.T., eds., The 2006 eruption of

  3. Staff - Janet R. Schaefer | Alaska Division of Geological & Geophysical

    Science.gov Websites

    . http://doi.org/10.14509/25602 Wallace, K.L., Schaefer, J.R., and Coombs, M.L., 2013, Character, mass ., Coombs, M.L., Diefenbach, A.K., Lopez, Taryn, McNutt, S.R., Neal, C.A., Payne, A.L., Power, J.A , J.E., Schilling, S.P., Schaefer, J.R., and Trusdell, F.A., 2007, Crisis GIS: Preparing for and

  4. Approximate, computationally efficient online learning in Bayesian spiking neurons.

    PubMed

    Kuhlmann, Levin; Hauser-Raspe, Michael; Manton, Jonathan H; Grayden, David B; Tapson, Jonathan; van Schaik, André

    2014-03-01

    Bayesian spiking neurons (BSNs) provide a probabilistic interpretation of how neurons perform inference and learning. Online learning in BSNs typically involves parameter estimation based on maximum-likelihood expectation-maximization (ML-EM) which is computationally slow and limits the potential of studying networks of BSNs. An online learning algorithm, fast learning (FL), is presented that is more computationally efficient than the benchmark ML-EM for a fixed number of time steps as the number of inputs to a BSN increases (e.g., 16.5 times faster run times for 20 inputs). Although ML-EM appears to converge 2.0 to 3.6 times faster than FL, the computational cost of ML-EM means that ML-EM takes longer to simulate to convergence than FL. FL also provides reasonable convergence performance that is robust to initialization of parameter estimates that are far from the true parameter values. However, parameter estimation depends on the range of true parameter values. Nevertheless, for a physiologically meaningful range of parameter values, FL gives very good average estimation accuracy, despite its approximate nature. The FL algorithm therefore provides an efficient tool, complementary to ML-EM, for exploring BSN networks in more detail in order to better understand their biological relevance. Moreover, the simplicity of the FL algorithm means it can be easily implemented in neuromorphic VLSI such that one can take advantage of the energy-efficient spike coding of BSNs.

  5. Left ventricular outflow tract mean systolic acceleration as a surrogate for the slope of the left ventricular end-systolic pressure-volume relationship

    NASA Technical Reports Server (NTRS)

    Bauer, Fabrice; Jones, Michael; Shiota, Takahiro; Firstenberg, Michael S.; Qin, Jian Xin; Tsujino, Hiroyuki; Kim, Yong Jin; Sitges, Marta; Cardon, Lisa A.; Zetts, Arthur D.; hide

    2002-01-01

    OBJECTIVE: The goal of this study was to analyze left ventricular outflow tract systolic acceleration (LVOT(Acc)) during alterations in left ventricular (LV) contractility and LV filling. BACKGROUND: Most indexes described to quantify LV systolic function, such as LV ejection fraction and cardiac output, are dependent on loading conditions. METHODS: In 18 sheep (4 normal, 6 with aortic regurgitation, and 8 with old myocardial infarction), blood flow velocities through the LVOT were recorded using conventional pulsed Doppler. The LVOT(Acc) was calculated as the aortic peak velocity divided by the time to peak flow; LVOT(Acc) was compared with LV maximal elastance (E(m)) acquired by conductance catheter under different loading conditions, including volume and pressure overload during an acute coronary occlusion (n = 10). In addition, a clinically validated lumped-parameter numerical model of the cardiovascular system was used to support our findings. RESULTS: Left ventricular E(m) and LVOT(Acc) decreased during ischemia (1.67 +/- 0.67 mm Hg.ml(-1) before vs. 0.93 +/- 0.41 mm Hg.ml(-1) during acute coronary occlusion [p < 0.05] and 7.9 +/- 3.1 m.s(-2) before vs. 4.4 +/- 1.0 m.s(-2) during coronary occlusion [p < 0.05], respectively). Left ventricular outflow tract systolic acceleration showed a strong linear correlation with LV E(m) (y = 3.84x + 1.87, r = 0.85, p < 0.001). Similar findings were obtained with the numerical modeling, which demonstrated a strong correlation between predicted and actual LV E(m) (predicted = 0.98 [actual] -0.01, r = 0.86). By analysis of variance, there was no statistically significant difference in LVOT(Acc) under different loading conditions. CONCLUSIONS: For a variety of hemodynamic conditions, LVOT(Acc) was linearly related to the LV contractility index LV E(m) and was independent of loading conditions. These findings were consistent with numerical modeling. Thus, this Doppler index may serve as a good noninvasive index of LV contractility.

  6. Using an EM Covariance Matrix to Estimate Structural Equation Models with Missing Data: Choosing an Adjusted Sample Size to Improve the Accuracy of Inferences

    ERIC Educational Resources Information Center

    Enders, Craig K.; Peugh, James L.

    2004-01-01

    Two methods, direct maximum likelihood (ML) and the expectation maximization (EM) algorithm, can be used to obtain ML parameter estimates for structural equation models with missing data (MD). Although the 2 methods frequently produce identical parameter estimates, it may be easier to satisfy missing at random assumptions using EM. However, no…

  7. Publications - RI 98-12 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    content DGGS RI 98-12 Publication Details Title: Geology of the Sleetmute C-7, C-8, D-7, and D-8 ., Miller, M.L., Layer, P.W., and Laird, G.M., 1999, Geology of the Sleetmute C-7, C-8, D-7, and D-8 ; Other Oversized Sheets Sheet 1 Geologic map of the Sleetmute C-7, C-8, D-7 and D-8 quadrangles, Horn

  8. Echinococcus multilocularis vesicular fluid inhibits activation and proliferation of natural killer cells.

    PubMed

    Bellanger, Anne-Pauline; Mougey, Valentine; Pallandre, Jean-Rene; Gbaguidi-Haore, Houssein; Godet, Yann; Millon, Laurence

    2017-08-25

    Alveolar echinococcosis is a severe chronic helminthic disease that mimics slow-growing liver cancer. The immune evasion strategy of Echinococcus multilocularis Leuckart, 1863 remains poorly understood. The aim of this study was to investigate in vitro the impact of E. multilocularis vesicular fluid (Em-VF) on peripheral blood mononuclear cells (PBMC) and on natural killer (NK) cells. PBMC and NK cells were exposed to Em-VF (1 µg/ml) during six days. The effect of Em-VF was assessed on CD69, viability and proliferation, and on and transforming growth factor β (TGF-β), interferon γ (IFN-γ), interleukin 17 (IL-17) and interleukin 10, using flow cytometry and ELISA, respectively. Exposure to Em-VF had no bearing on PBMC's viability, proliferation and expression of CD69. In contrast, higher levels of IL-17 at day three and of TGF-β at day six were observed in PBMC supernatant after exposure to Em-VF (p < 0.05, Wilcoxon signed-rank test). Exposure to Em-VF induced a significant decrease of CD69 expression of NK cells at day three and a significant decrease of proliferation of NK cells at day six (p < 0.05, Wilcoxon signed-rank test). In contrast, NK cells viability and levels of cytokines did not vary significantly over Em-VF stimulation. Exposure to Em-VF had a significant bearing on activation and proliferation of NK cells. NK cells may play an important role in the immune response of the host against E. multilocularis.

  9. Publications - RI 2001-1B | Alaska Division of Geological & Geophysical

    Science.gov Websites

    content DGGS RI 2001-1B Publication Details Title: Geologic map of the Chulitna region, southcentral , M.L., Reifenstuhl, R.R., and Clough, J.G., 2001, Geologic map of the Chulitna region, southcentral of the Chulitna region, southcentral Alaska, scale 1:63,360 (12.0 M) Digital Geospatial Data Digital

  10. Publications - PDF 93-47 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    content DGGS PDF 93-47 Publication Details Title: Geologic map of the Sleetmute C-7, D-7, C-8, and D-8 ., Harris, E.E., Kline, J.T., and Miller, M.L., 1993, Geologic map of the Sleetmute C-7, D-7, C-8, and D-8 Sleetmute C-7, C-8, D-7 and D-8 quadrangles, Horn Mountain Area, southwest Alaska, scale 1:63,360 (34.0 M

  11. Effective microorganism - X attenuates circulating superoxide dismutase following an acute bout of intermittent running in hot, humid conditions.

    PubMed

    Taylor, Lee; Lee, Ben J; Gibson, Oliver R; Midgley, Adrian W; Watt, Peter; Mauger, Alexis; Castle, Paul

    2016-01-01

    This study determined the effectiveness of antioxidant supplementation on high-intensity exercise-heat stress. Six males completed a high-intensity running protocol twice in temperate conditions (TEMP; 20.4°C), and twice in hot conditions (HOT; 34.7°C). Trials were completed following7 days supplementation with 70 ml·day(-1) effective microorganism-X (EM-X; TEMPEMX or HOTEMX) or placebo (TEMPPLA or HOTPLA). Plasma extracellular Hsp72 (eHsp72) and superoxide dismutase (SOD) were measured by ELISA. eHsp72 and SOD increased pre-post exercise (p < 0.001), with greater eHsp72 (p < 0.001) increases observed in HOT (+1.5 ng·ml(-1)) compared to TEMP (+0.8 ng·ml(-1)). EM-X did not influence eHsp72 (p > 0.05). Greater (p < 0.001) SOD increases were observed in HOT (+0.22 U·ml(-1)) versus TEMP (+0.10 U·ml(-1)) with SOD reduced in HOTEMX versus HOTPLA (p = 0.001). Physiological and perceptual responses were all greater (p < 0.001) in HOT versus TEMP conditions, with no difference followed EM-X (p > 0.05). EM-X supplementation attenuated the SOD increases following HOT, potentiating its application as an ergogenic aid to ameliorate oxidative stress.

  12. Biotransformation of L-tyrosine to Dopamine by a Calcium Alginate Immobilized Mutant Strain of Aspergillus oryzae.

    PubMed

    Ali, Sikander; Nawaz, Wajeeha

    2016-08-01

    The present research work is concerned with the biotransformation of L-tyrosine to dopamine (DA) by calcium alginate entrapped conidiospores of a mutant strain of Aspergillus oryzae. Different strains of A. oryzae were isolated from soil. Out of 13 isolated strains, isolate-2 (I-2) was found to be a better DA producer. The wild-type I-2 was chemically improved by treating it with different concentrations of ethyl methyl sulfonate (EMS). Among seven mutant variants, EMS-6 exhibiting maximal DA activity of 43 μg/ml was selected. The strain was further exposed with L-cysteine HCl to make it resistant against diversion and environmental stress. The conidiospores of selected mutant variant A. oryzae EMS-6 strain were entrapped in calcium alginate beads. Different parameters for immobilization were investigated. The activity was further improved from 44 to 62 μg/ml under optimized conditions (1.5 % sodium alginate, 2 ml inoculum, and 2 mm bead size). The best resistant mutant variable exhibited over threefold increase in DA activity (62 μg/ml) than did wild-type I-2 (21 μg/ml) in the reaction mixture. From the results presented in the study, it was observed that high titers of DA activity in vitro could effectively be achieved by the EMS-induced mutagenesis of filamentous fungus culture used.

  13. Hybrid: Cruising

    Science.gov Websites

    battery, engine, and electric motor visible. The car is moving. There are red arrows flowing from the gasoline engine to the front wheels. There are blue arrows flowing from the gasoline engine to the electric car is moving. There are red arrows flowing from the gasoline engine to the front wheels. There are

  14. Utility of Experimental Design in Pre-Column Derivatization for the Analysis of Tobramycin by HPLC-Fluorescence Detection: Application to Ophthalmic Solution and Human Plasma.

    PubMed

    El-Zaher, Asmaa A; Mahrouse, Marianne A

    2013-01-01

    A novel, selective, and sensitive reversed phase high-performance liquid chromatography (HPLC) method coupled with fluorescence detection has been developed for the determination of tobramycin (TOB) in pure form, in ophthalmic solution and in spiked human plasma. Since TOB lacks UV absorbing chromophores and native fluorescence, pre-column derivatization of TOB was carried out using fluorescamine reagent (0.01%, 1.5 mL) and borate buffer (pH 8.5, 2 mL). Experimental design was applied for optimization of the derivatization step. The resulting highly fluorescent stable derivative was chromatographed on C18 column and eluted using methanol:water (60:40, v/v) at a flow rate of 1 mL min(-1). A fluorescence detector (λex 390 and λem 480 nm) was used. The method was linear over the concentration range 20-200 ng mL(-1). The structure of the fluorescent product was proposed, the method was then validated and applied for the determination of TOB in human plasma. The results were statistically compared with the reference method, revealing no significant difference.

  15. Stop/Start: Driving

    Science.gov Websites

    /generator visible. The car is moving. There are purple arrows flowing from the gasoline engine to the electric starter/generator. There are red arrows flowing from the gasoline engine to the front wheels . There are blue arrows flowing from the electric starter/generator to the battery. Main stage: See

  16. Novel liquid chromatographic assay for the low-level determination of apomorphine in plasma.

    PubMed

    Priston, M J; Sewell, G J

    1996-05-31

    A novel HPLC assay which is rapid, reproducible and sensitive has been developed for the analysis of apomorphine in plasma. The assay incorporates boldine as an internal standard, and uses solid-phase extraction on C18 mini-columns for sample clean-up and concentration, so enabling quantitation of apomorphine at 500 pg/ml using fluorescence detection (lambda(ex) 270 nm, lambda(em) 450 nm). The HPLC assay comprised a 25 cm-long Techopak C18 column and a mobile phase of (0.25 M sodium dihydrogen phosphate plus 0.25% heptane sulphonic acid, to pH 3.3 with orthophosphoric acid) containing 30% (v/v) methanol and 0.003% (w/v) EDTA, run at a flow-rate of 1.5 ml/min. Calibration plots prepared in plasma were linear over the range 1-30 ng/ml, (limit of quantitation (LOQ) = 490 pg/ml) with R.S.D. of 0.05% and R.E. of 5.0% at the level of 1 ng/ml. Preliminary pharmacokinetic data from two patients given apomorphine by 12 h subcutaneous infusion (patient A dose = 35 mg and patient B dose = 141 mg) showed apomorphine elimination from plasma to fit a two-compartment model, with initial half-lives of 8.2 and 46.6 min, elimination half-lives of 76.4 and 166.5 min and area under the plasma concentration-time curve (AUC) values of 236 and 405 ng h/ml, respectively.

  17. Cometabolic degradation of ethyl mercaptan by phenol-utilizing Ralstonia eutropha in suspended growth and gas-recycling trickle-bed reactor.

    PubMed

    Sedighi, Mahsa; Zamir, Seyed Morteza; Vahabzadeh, Farzaneh

    2016-01-01

    The degradability of ethyl mercaptan (EM), by phenol-utilizing cells of Ralstonia eutropha, in both suspended and immobilized culture systems, was investigated in the present study. Free-cells experiments conducted at EM concentrations ranging from 1.25 to 14.42 mg/l, showed almost complete removal of EM at concentrations below 10.08 mg/l, which is much higher than the maximum biodegradable EM concentration obtained in experiments that did not utilize phenol as the primary substrate, i.e. 2.5 mg/l. The first-order kinetic rate constant (kSKS) for EM biodegradation by the phenol-utilizing cells (1.7 l/g biomass/h) was about 10 times higher than by cells without phenol utilization. Immobilized-cells experiments performed in a gas recycling trickle-bed reactor packed with kissiris particles at EM concentrations ranging from 1.6 to 36.9 mg/l, showed complete removal at all tested concentrations in a much shorter time, compared with free cells. The first-order kinetic rate constant (rmaxKs) for EM utilization was 0.04 l/h for the immobilized system compared to 0.06 for the suspended-growth culture, due to external mass transfer diffusion. Diffusion limitation was decreased by increasing the recycling-liquid flow rate from 25 to 65 ml/min. The removed EM was almost completely mineralized according to TOC and sulfate measurements. Shut down and starvation experiments revealed that the reactor could effectively handle the starving conditions and was reliable for full-scale application. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Ultrasound-guided intrapleural positioning of pleural catheters: influence on immediate lung expansion and pleurodesis in patients with recurrent malignant pleural effusion.

    PubMed

    Araujo, Pedro Henrique Xavier Nabuco de; Terra, Ricardo Mingarini; Santos, Thiago da Silva; Chate, Rodrigo Caruso; Paiva, Antonio Fernando Lins de; Pêgo-Fernandes, Paulo Manuel

    2017-01-01

    To evaluate the role of intrapleural positioning of a pleural catheter in early lung expansion and pleurodesis success in patients with recurrent malignant pleural effusion (RMPE). This was a retrospective study nested into a larger prospective cohort study including patients with RMPE recruited from a tertiary university teaching hospital between June of 2009 and September of 2014. The patients underwent pleural catheter insertion followed by bedside pleurodesis. Chest CT scans were performed twice: immediately before pleurodesis (iCT) and 30 days after pleurodesis (CT30). Catheter positioning was categorized based on iCT scans as posterolateral, anterior, fissural, and subpulmonary. We used the pleural volume on iCT scans to estimate early lung expansion and the difference between the pleural volumes on CT30 and iCT scans to evaluate radiological success of pleurodesis. Clinical pleurodesis success was defined as no need for any other pleural procedure. Of the 131 eligible patients from the original study, 85 were included in this nested study (64 women; mean age: 60.74 years). Catheter tip positioning was subpulmonary in 35 patients (41%), anterior in 23 (27%), posterolateral in 17 (20%), and fissural in 10 (12%). No significant differences were found among the groups regarding early lung expansion (median residual pleural cavity = 377 mL; interquartile range: 171-722 mL; p = 0.645), radiological success of pleurodesis (median volume = 33 mL; interquartile range: -225 to 257 mL; p = 0.923), and clinical success of pleurodesis (85.8%; p = 0.676). Our results suggest that the position of the tip of the pleural catheter influences neither early lung expansion nor bedside pleurodesis success in patients with RMPE. Avaliar o papel do posicionamento intrapleural do cateter pleural na expansão pulmonar precoce e no sucesso da pleurodese em pacientes com derrame pleural maligno recorrente (DPMR). Trata-se de um estudo retrospectivo aninhado em um estudo prospectivo de coorte maior com pacientes com DPMR recrutados em um hospital-escola universitário terciário entre junho de 2009 e setembro de 2014. Os pacientes foram submetidos a inserção de cateter pleural e, em seguida, pleurodese à beira do leito. A TC de tórax foi realizada duas vezes: imediatamente antes da pleurodese (TCi) e 30 dias após a pleurodese (TC30). Com base na TCi, a posição do cateter foi classificada em posterolateral, anterior, fissural e subpulmonar. Usamos o volume pleural na TCi para estimar a expansão pulmonar precoce e a diferença entre os volumes pleurais na TC30 e na TCi a fim de avaliar o sucesso radiológico da pleurodese. Considerou-se que a pleurodese teve êxito clínico quando não foi necessário realizar nenhum outro procedimento pleural. Dos 131 pacientes elegíveis do estudo original, 85 foram incluídos neste estudo aninhado (64 mulheres; média de idade: 60,74 anos). A posição da ponta do cateter foi subpulmonar em 35 pacientes (41%), anterior em 23 (27%), posterolateral em 17 (20%) e fissural em 10 (12%). Não houve diferenças significativas entre os grupos quanto à expansão pulmonar precoce (mediana da cavidade pleural residual = 377 ml; intervalo interquartil: 171-722 ml; p = 0,645), sucesso radiológico da pleurodese (mediana do volume = 33 ml; intervalo interquartil: -225 a 257 ml; p = 0,923) e sucesso clínico da pleurodese (85,8%; p = 0,676). Nossos resultados sugerem que a posição da ponta do cateter pleural não influencia nem a expansão pulmonar precoce nem o sucesso da pleurodese à beira do leito em pacientes com DPMR.

  19. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies

    NASA Astrophysics Data System (ADS)

    Winant, Celeste D.; Aparici, Carina Mari; Zelnik, Yuval R.; Reutter, Bryan W.; Sitek, Arkadiusz; Bacharach, Stephen L.; Gullberg, Grant T.

    2012-01-01

    Computer simulations, a phantom study and a human study were performed to determine whether a slowly rotating single-photon computed emission tomography (SPECT) system could provide accurate arterial input functions for quantification of myocardial perfusion imaging using kinetic models. The errors induced by data inconsistency associated with imaging with slow camera rotation during tracer injection were evaluated with an approach called SPECT/P (dynamic SPECT from positron emission tomography (PET)) and SPECT/D (dynamic SPECT from database of SPECT phantom projections). SPECT/P simulated SPECT-like dynamic projections using reprojections of reconstructed dynamic 94Tc-methoxyisobutylisonitrile (94Tc-MIBI) PET images acquired in three human subjects (1 min infusion). This approach was used to evaluate the accuracy of estimating myocardial wash-in rate parameters K1 for rotation speeds providing 180° of projection data every 27 or 54 s. Blood input and myocardium tissue time-activity curves (TACs) were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K1. For the second method (SPECT/D), an anthropomorphic cardiac torso phantom was used to create real SPECT dynamic projection data of a tracer distribution derived from 94Tc-MIBI PET scans in the blood pool, myocardium, liver and background. This method introduced attenuation, collimation and scatter into the modeling of dynamic SPECT projections. Both approaches were used to evaluate the accuracy of estimating myocardial wash-in parameters for rotation speeds providing 180° of projection data every 27 and 54 s. Dynamic cardiac SPECT was also performed in a human subject at rest using a hybrid SPECT/CT scanner. Dynamic measurements of 99mTc-tetrofosmin in the myocardium were obtained using an infusion time of 2 min. Blood input, myocardium tissue and liver TACs were estimated using the same spatiotemporal splines. The spatiotemporal maximum-likelihood expectation-maximization (4D ML-EM) reconstructions gave more accurate reconstructions than did standard frame-by-frame static 3D ML-EM reconstructions. The SPECT/P results showed that 4D ML-EM reconstruction gave higher and more accurate estimates of K1 than did 3D ML-EM, yielding anywhere from a 44% underestimation to 24% overestimation for the three patients. The SPECT/D results showed that 4D ML-EM reconstruction gave an overestimation of 28% and 3D ML-EM gave an underestimation of 1% for K1. For the patient study the 4D ML-EM reconstruction provided continuous images as a function of time of the concentration in both ventricular cavities and myocardium during the 2 min infusion. It is demonstrated that a 2 min infusion with a two-headed SPECT system rotating 180° every 54 s can produce measurements of blood pool and myocardial TACs, though the SPECT simulation studies showed that one must sample at least every 30 s to capture a 1 min infusion input function.

  20. Hormonal responses to resistance exercise during different menstrual cycle states.

    PubMed

    Nakamura, Yuki; Aizawa, Katsuji; Imai, Tomoko; Kono, Ichiro; Mesaki, Noboru

    2011-06-01

    To investigate the effect of menstrual cycle states on ovarian and anabolic hormonal responses to acute resistance exercise in young women. Eight healthy women (eumenorrhea; EM) and eight women with menstrual disorders including oligomenorrhea and amenorrhea (OAM) participated in this study. The EM group performed acute resistance exercises during the early follicular (EF) and midluteal (ML) phases, and the OAM group performed the same exercises. All subjects performed three sets each of lat pull-downs, leg curls, bench presses, leg extensions, and squats at 75%-80% of one-repetition maximum with a 1-min rest between sets. Blood samples were obtained before exercise, immediately after, 30 min after, and 60 min after the exercise. In the EM group, resting serum levels of estradiol and progesterone in the ML phase were higher than those in the EF phase and higher than those in the OAM group. Serum estradiol and progesterone in the ML phase increased after the exercise but did not change in the EF phase or in the OAM group. In contrast, resting levels of testosterone in the OAM group were higher than those in both the ML and EF phases of the EM group. After the exercise, serum growth hormone increased in both the ML and EF phases but did not change in the OAM group. The responses of anabolic hormones to acute resistance exercise are different among the menstrual cycle states in young women. Women with menstrual disturbances with low estradiol and progesterone serum levels have an attenuated anabolic hormone response to acute resistance exercise, suggesting that menstrual disorders accompanying low ovarian hormone levels may affect exercise-induced change in anabolic hormones in women.

  1. Publications | Grid Modernization | NREL

    Science.gov Websites

    Photovoltaics: Trajectories and Challenges Cover of Efficient Relaxations for Joint Chance Constrained AC Optimal Power Flow publication Efficient Relaxations for Joint Chance Constrained AC Optimal Power Flow

  2. Relationship between preoperative radial artery and postoperative arteriovenous fistula blood flow in hemodialysis patients.

    PubMed

    Sato, Michiko; Io, Hiroaki; Tanimoto, Mitsuo; Shimizu, Yoshio; Fukui, Mitsumine; Hamada, Chieko; Horikoshi, Satoshi; Tomino, Yasuhiko

    2012-01-01

    It is recommended that arteriovenous fistula (AVF) blood flow should be more than 425 ml/min before cannulation. However, the relationship between preoperative radial artery flow (RAF) and postoperative AVF blood flow has still not been examined. Sixty-one patients with end-stage kidney disease (ESKD) were examined. They had an AVF prepared at Juntendo University Hospital from July 2006 through August 2007. Preoperative RAF and postoperative AVF blood flows were measured by ultrasonography. AVF blood flow gradually increased after the operation. AVF blood flow was significantly correlated with preoperative RAF. When preoperative RAF exceeded 21.4 ml/min, AVF blood flow rose to more than 425 ml/min. The postoperative AVF blood flow in the group with RAF of more than 20 ml/min was significantly higher than that in those with less than 20 ml/min. Preoperative RAF of less than 20 ml/min had a significantly high risk of primary AVF failure within 8 months compared with that of more than 20 ml/min. It appears that measurement of RAF by ultrasonography is useful for estimating AVF blood flow postoperatively and can predict the risk of complications in ESKD patients.

  3. Utility of Experimental Design in Pre-Column Derivatization for the Analysis of Tobramycin by HPLC—Fluorescence Detection: Application to Ophthalmic Solution and Human Plasma

    PubMed Central

    El-Zaher, Asmaa A.; Mahrouse, Marianne A.

    2013-01-01

    A novel, selective, and sensitive reversed phase high-performance liquid chromatography (HPLC) method coupled with fluorescence detection has been developed for the determination of tobramycin (TOB) in pure form, in ophthalmic solution and in spiked human plasma. Since TOB lacks UV absorbing chromophores and native fluorescence, pre-column derivatization of TOB was carried out using fluorescamine reagent (0.01%, 1.5 mL) and borate buffer (pH 8.5, 2 mL). Experimental design was applied for optimization of the derivatization step. The resulting highly fluorescent stable derivative was chromatographed on C18 column and eluted using methanol:water (60:40, v/v) at a flow rate of 1 mL min−1. A fluorescence detector (λex 390 and λem 480 nm) was used. The method was linear over the concentration range 20–200 ng mL−1. The structure of the fluorescent product was proposed, the method was then validated and applied for the determination of TOB in human plasma. The results were statistically compared with the reference method, revealing no significant difference. PMID:23700362

  4. [Hemodynamic changes in portal system after transjugular intrahepatic portosystemic shunts (TIPS)].

    PubMed

    Li, W; Xiao, Y; Xu, H

    1995-08-01

    In this study portal venous flow (PVF), splenic venous flow (SPVF), hepatic artery volume (HAV), and portal pressure were measured before and after TIPS in 11 patients with portal hypertension. The results were compared with those of normal controls. In the normal controls PVF averaged 947.2 +/- 133.4ml/min, SPVF 239.6 +/- 116.3ml/min, and HAV 241.6 +/- 78.8ml/min. In the TIPS group before and after TIPS, PVF was 883.2 +/- 233.4ml/min vs. 958.7 +/- 185.2ml/min; SPVF was 448.9 +/- 111.6ml/min vs. 333.1 +/- 101.5ml/min; HVP was 225.3 +/- 122.7ml/min vs. 249.3 +/- 103.8ml/min. Portal pressure dropped from 3.94kPa +/- 0.46 to 2.52 +/- 0.60kPa after TIPS. We conclude that in patients after TIPS portal pressure drops blood flow in the truck of the portal vein increases, flow of hepatic tissue decreases, and blood flow in splenic vein decreases. Blood flow in hepatic aftery was not significantly changed.

  5. Compare Vehicle Technologies | Transportation Research | NREL

    Science.gov Websites

    electric car diagramming energy storage, power electronics, and climate control components, as well as storage, power electronics, and climate control components, as well as energy flow among components. 3-D control components, as well as energy flow among components. 3-D illustration of electric car diagramming

  6. Publications | Regional Energy Deployment System Model | Energy Analysis |

    Science.gov Websites

    Methodologies: Approximated DC Flow vs. Pipe Flow along AC Lines. Golden, CO: National Renewable Energy Energy. DOE/GO-102015-4557. Macknick, Jordan, and Stuart Cohen. 2015. Water Impacts of High Solar PV , Jordan, Stuart Cohen, Robin Newmark, Andrew Martinez, Patrick Sullivan, and Vince Tidwell. 2015. Water

  7. Hybrid: Passing

    Science.gov Websites

    accelerating or when additional power is needed, the gasoline engine and electric motor are both used to propel . The car is passing another vehicle. There are red arrows flowing from the gasoline engine to the front wheels. There are blue arrows flowing from the battery to the electric engine to the front wheels. Main

  8. Ray Grout | NREL

    Science.gov Websites

    cross flow from peta-scale, high-fidelity simulations in collaboration with the gas turbine industry. A stratified combustion in the stabilization of flames above a jet in cross flow. Earlier work involved using

  9. Metallurgical technologies, energy conversion, and magnetohydrodynamic flows

    NASA Astrophysics Data System (ADS)

    Branover, Herman; Unger, Yeshajahu

    The present volume discusses metallurgical applications of MHD, R&D on MHD devices employing liquid working medium for process applications, electromagnetic (EM) modulation of molten metal flow, EM pump performance of superconducting MHD devices, induction EM alkali-metal pumps, a physical model for EM-driven flow in channel-induction furnaces, grain refinement in Al alloys via EM vibrational method, dendrite growth of solidifying metal in dc magnetic field, MHD for mass and heat transfer in single-crystal melt growth, inverse EM shaping, and liquid-metal MHD development in Israel. Also discussed are the embrittlement of steel by lead, an open cycle MHD disk generator, the acceleration of gas-liquid piston flows for molten-metal MHD generators, MHD flow around a cylinder, new MHD drag coefficients, liquid-metal MHD two-phase flow, and two-phase liquid gas mixers for MHD energy conversion. (No individual items are abstracted in this volume)

  10. Energy Secretary Dedicates ESIF at NREL | News | NREL

    Science.gov Websites

    -like screen how wind turbine blades can alter the wind flow as it approaches other turbines downstream flows downstream when the blades hit it. A man with his back to the camera explains the process, while

  11. Improved Understanding of In Situ Chemical Oxidation. Technical Objective 2: Soil Reactivity

    DTIC Science & Technology

    2009-05-01

    each reaction tube. The reagents ( sulfuric acid /potassium dichromate/mercury sulfate ) were prepared following standard methods (APHA, 1998). When...reaction tubes. A volume (~20 mL) of potassium dichromate digestion solution (potassium dichromate (BDH Laboratories), sulfuric acid (EM Science...and mercury sulphate (EM Science)) and a sulfuric acid reagent solution ( sulfuric acid (EM Science) and silver sulphate (Alfa Aesar)) were added to

  12. Minimal vascular flows cause strong heat sink effects in hepatic radiofrequency ablation ex vivo.

    PubMed

    Lehmann, Kai S; Poch, Franz G M; Rieder, Christian; Schenk, Andrea; Stroux, Andrea; Frericks, Bernd B; Gemeinhardt, Ole; Holmer, Christoph; Kreis, Martin E; Ritz, Jörg P; Zurbuchen, Urte

    2016-08-01

    The present paper aims to assess the lower threshold of vascular flow rate on the heat sink effect in bipolar radiofrequency ablation (RFA) ex vivo. Glass tubes (vessels) of 3.4 mm inner diameter were introduced in parallel to bipolar RFA applicators into porcine liver ex vivo. Vessels were perfused with flow rates of 0 to 1,500 ml/min. RFA (30 W power, 15 kJ energy input) was carried out at room temperature and 37°C. Heat sink effects were assessed in RFA cross sections by the decrease in ablation radius, area and by a high-resolution sector planimetry. Flow rates of 1 ml/min already caused a significant cooling effect (P ≤ 0.001). The heat sink effect reached a maximum at 10 ml/min (18.4 mm/s) and remained stable for flow rates up to 1,500 ml/min. Minimal vascular flows of ≥1 ml/min cause a significant heat sink effect in hepatic RFA ex vivo. A lower limit for volumetric flow rate was not found. The maximum of the heat sink effect was reached at a flow rate of 10 ml/min and remained stable for flow rates up to 1,500 ml/min. Hepatic inflow occlusion should be considered in RFA close to hepatic vessels. © 2016 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  13. Measurement and Structural Model Class Separation in Mixture CFA: ML/EM versus MCMC

    ERIC Educational Resources Information Center

    Depaoli, Sarah

    2012-01-01

    Parameter recovery was assessed within mixture confirmatory factor analysis across multiple estimator conditions under different simulated levels of mixture class separation. Mixture class separation was defined in the measurement model (through factor loadings) and the structural model (through factor variances). Maximum likelihood (ML) via the…

  14. Smart catheter flow sensor for real-time continuous regional cerebral blood flow monitoring

    NASA Astrophysics Data System (ADS)

    Li, Chunyan; Wu, Pei-Ming; Hartings, Jed A.; Wu, Zhizhen; Ahn, Chong H.; LeDoux, David; Shutter, Lori A.; Narayan, Raj K.

    2011-12-01

    We present a smart catheter flow sensor for real-time, continuous, and quantitative measurement of regional cerebral blood flow using in situ temperature and thermal conductivity compensation. The flow sensor operates in a constant-temperature mode and employs a periodic heating and cooling technique. This approach ensures zero drift and provides highly reliable data with microelectromechanical system-based thin film sensors. The developed flow sensor has a sensitivity of 0.973 mV/ml/100 g/min in the range from 0 to 160 ml/100 g/min with a linear correlation coefficient of R2 = 0.9953. It achieves a resolution of 0.25 ml/100 g/min and an accuracy better than 5 ml/100 g/min.

  15. Department of Navy Chief Information Officer

    Science.gov Websites

    (6) Freedom of Information Act (29) IT Investment Management (47) Records Management (37 Management and Knowledge Management programs. DON CIO Information About the DON CIO Website Accessibility this website is to facilitate effective information flow about information management/information

  16. Publications - GMC 332 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    DGGS GMC 332 Publication Details Title: X-Ray Diffraction analysis and flow testing of Hemlock information. Quadrangle(s): Alaska Statewide Bibliographic Reference BJ Services Company , 2006, X-Ray

  17. Development of enantioselective chemiluminescence flow- and sequential-injection immunoassays for alpha-amino acids.

    PubMed

    Silvaieh, Hossein; Schmid, Martin G; Hofstetter, Oliver; Schurig, Volker; Gübitz, Gerald

    2002-01-01

    The development of an enantioselective flow-through chemiluminescence immunosensor for amino acids is described. The approach is based on a competitive assay using enantioselective antibodies. Two different instrumental approaches, a flow-injection (FIA) and a sequential-injection system (SIA), are used. Compared to the flow-injection technique, the sequential injection-mode showed better repeatability. Both systems use an immunoreactor consisting of a flow cell packed with immobilized haptens. The haptens (4-amino-L- or D-phenylalanine) are immobilized onto a hydroxysuccinimide-activated polymer (Affi-prep 10) via a tyramine spacer. Stereoselective antibodies, raised against 4-amino-L- or D-phenylalanine, are labeled with an acridinium ester. Stereoselective inhibition of binding of the acridinum-labeled antibodies to the immobilized hapten by amino acids takes place. Chiral recognition was observed not only for the hapten molecule but also for a series of different amino acids. One assay cycle including regeneration takes 6:30 min in the FIA mode and 4:40 min in the SIA mode. Using D-phenylalanine as a sample, the detection limit was found to be 6.13 pmol/ml (1.01 ng/ml) for the flow-injection immunoassay (FIIA) and 1.76 pmol/ml (0.29 ng/ml ) for the sequential-injection immunoassay (SIIA) which can be lowered to 0.22 pmol/ml (0.036 ng/ml) or 0.064 pmol/ml (0.01 ng/ml) by using a stopped flow system. The intra-assay repeatability was found to be about 5% RSD and the inter-assay repeatability below 6% (within 3 days).

  18. Hariswaran Sitaraman | NREL

    Science.gov Websites

    pertaining to combustion and particulate flows. Education 2013 Ph.D., Aerospace Engineering, UT, Austin 2010 M.S., Aerospace Engineering, UT, Austin 2008 B. Tech, Aerospace Engineering, IIT Madras, Chennai

  19. Dextrose 10% in the treatment of out-of-hospital hypoglycemia.

    PubMed

    Kiefer, Matthew V; Gene Hern, H; Alter, Harrison J; Barger, Joseph B

    2014-04-01

    Prehospital first responders historically have treated hypoglycemia in the field with an IV bolus of 50 mL of 50% dextrose solution (D50). The California Contra Costa County Emergency Medical Services (EMS) system recently adopted a protocol of IV 10% dextrose solution (D10), due to frequent shortages and relatively high cost of D50. The feasibility, safety, and efficacy of this approach are reported using the experience of this EMS system. Over the course of 18 weeks, paramedics treated 239 hypoglycemic patients with D10 and recorded patient demographics and clinical outcomes. Of these, 203 patients were treated with 100 mL of D10 initially upon EMS arrival, and full data on response to treatment was available on 164 of the 203 patients. The 164 patients' capillary glucose response to initial infusion of 100 mL of D10 was calculated and a linear regression line fit between elapsed time and difference between initial and repeat glucose values. Feasibility, safety, and the need for repeat glucose infusions were examined. The study cohort included 102 men and 62 women with a median age of 68 years. The median initial field blood glucose was 38 mg/dL, with a subsequent blood glucose median of 98 mg/dL. The median time to second glucose testing was eight minutes after beginning the 100 mL D10 infusion. Of 164 patients, 29 (18%) required an additional dose of IV D10 solution due to persistent or recurrent hypoglycemia, and one patient required a third dose. There were no reported adverse events or deaths related to D10 administration. Linear regression analysis of elapsed time and difference between initial and repeat glucose values showed near-zero correlation. In addition to practical reasons of cost and availability, theoretical risks of using 50 mL of D50 in the out-of-hospital setting include extravasation injury, direct toxic effects of hypertonic dextrose, and potential neurotoxic effects of hyperglycemia. The results of one local EMS system over an 18-week period demonstrate the feasibility, safety, and efficacy of using 100 mL of D10 as an alternative. Additionally, the linear regression line of repeat glucose measurements suggests that there may be little or no short-term decay in blood glucose values after D10 administration.

  20. Mobile Launcher

    NASA Image and Video Library

    2017-05-30

    A view of the mobile launcher (ML) taken from the "eyebrow" of the nearby Vehicle Assembly Building at NASA's Kennedy Space Center in Florida. The ML tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The Orion Service Module Umbilical and Core State Forward Skirt Umbilical were recently installed on the ML. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  1. Lung Function in Rescue Workers at the World Trade Center after 7 Years

    PubMed Central

    Aldrich, Thomas K.; Gustave, Jackson; Hall, Charles B.; Cohen, Hillel W.; Webber, Mayris P.; Zeig-Owens, Rachel; Cosenza, Kaitlyn; Christodoulou, Vasilios; Glass, Lara; Al-Othman, Fairouz; Weiden, Michael D.; Kelly, Kerry J.; Prezant, David J.

    2016-01-01

    Background The terrorist attacks on the World Trade Center on September 11, 2001, exposed thousands of Fire Department of New York City (FDNY) rescue workers to dust, leading to substantial declines in lung function in the first year. We sought to determine the longer-term effects of exposure. Methods Using linear mixed models, we analyzed the forced expiratory volume in 1 second (FEV1) of both active and retired FDNY rescue workers on the basis of spirometry routinely performed at intervals of 12 to 18 months from March 12, 2000, to September 11, 2008. Results Of the 13,954 FDNY workers who were present at the World Trade Center between September 11, 2001, and September 24, 2001, a total of 12,781 (91.6%) participated in this study, contributing 61,746 quality-screened spirometric measurements. The median follow-up was 6.1 years for firefighters and 6.4 years for emergency-medical-services (EMS) workers. In the first year, the mean FEV1 decreased significantly for all workers, more for firefighters who had never smoked (a reduction of 439 ml; 95% confidence interval [CI], 408 to 471) than for EMS workers who had never smoked (a reduction of 267 ml; 95% CI, 263 to 271) (P<0.001 for both comparisons). There was little or no recovery in FEV1 during the subsequent 6 years, with a mean annualized reduction in FEV1 of 25 ml per year for firefighters and 40 ml per year for EMS workers. The proportion of workers who had never smoked and who had an FEV1 below the lower limit of the normal range increased during the first year, from 3% to 18% for firefighters and from 12% to 22% for EMS workers, stabilizing at about 13% for firefighters and 22% for EMS workers during the subsequent 6 years. Conclusions Exposure to World Trade Center dust led to large declines in FEV1 for FDNY rescue workers during the first year. Overall, these declines were persistent, without recovery over the next 6 years, leaving a substantial proportion of workers with abnormal lung function. PMID:20375403

  2. Enhanced ventricular pump function and decreased reservoir backflow sustain rise in pulmonary blood flow after reduction of lung liquid volume in fetal lambs.

    PubMed

    Smolich, Joseph J

    2014-02-15

    Although a reduction in lung liquid volume increases fetal pulmonary blood flow, the changes in central flow patterns that sustain this increased pulmonary perfusion are unknown. To address this issue, eight anesthetized late-gestation fetal sheep were instrumented with pulmonary trunk (PT), ductus arteriosus (DA), and left pulmonary artery (PA) micromanometer catheters and transit-time flow probes, with blood flow profile and wave intensity analyses performed at baseline and after withdrawal of lung liquid via an endotracheal tube. Reducing lung liquid volume by 19 ± 6 ml/kg (mean ± SD) augmented right ventricular power by 34% (P < 0.001), with distribution of an accompanying increase in mean PT blood flow (245 ± 63 ml/min, P < 0.001) to the lungs (169 ± 91 ml/min, P = 0.001) and across the DA (77 ± 92 ml/min, P = 0.04). However, although PT and DA flow increments were confined to systole and were related to an increased magnitude of flow-increasing, forward-running compression waves, the rise in PA flow spanned both systole (108 ± 66 ml/min) and diastole (61 ± 32 ml/min). Flow profile analysis showed that the step-up in PA diastolic flow was associated with diminished PA diastolic backflow and accompanied by a lesser degree of diastolic right-to-left DA shunting. These data suggest that an increased pulmonary blood flow after reduction of lung liquid volume is associated with substantial changes in PT-DA-PA interactions and underpinned by two main factors: 1) enhanced right ventricular pump function that increases PA systolic inflow and 2) decreased PA diastolic backflow that arises from a fundamental change in PA reservoir function, thereby resulting in greater passage of systolic inflow through the lungs.

  3. Full Hybrid: Cruising

    Science.gov Websites

    1 At speeds above mid-range, both the engine and electric motor are used to propel the vehicle. The gasoline engine provides power to the drive-train directly and to the electric motor via the generator. Go , generator, power split device, and electric motor visible. The car is moving. There are blue arrows flowing

  4. River Flow Advisory Commission: Snow Survey

    Science.gov Websites

    Survey River Watch Home → Snow Survey RFAC Information About Us Reports Maine Cooperative Snow Survey About the Snow Survey Snow Survey Map Compare Snow Survey Data Snow Survey Graphs River Watch MEMA Home USGS (Maine) Home Maine Cooperative Snow Survey This information is provided by a partnership with

  5. Use of nonimaging nuclear medicine techniques to assess the effect of flunixin meglumine on effective renal plasma flow and effective renal blood flow in healthy horses.

    PubMed

    Held, J P; Daniel, G B

    1991-10-01

    The effect of flunixin meglumine on renal function was studied in 6 healthy horses by use of nonimaging nuclear medicine techniques. Effective renal plasma flow (ERPF) and effective renal blood flow (ERBF) were determined by plasma clearance of 131I-orthoiodohippuric acid before and after administration of flunixin meglumine. Mean ERPF and ERBF was 6.03 ml/min/kg and 10.7 ml/min/kg, respectively, before treatment and was 5.7 ml/min/kg and 9.7 ml/min/kg, respectively, after treatment. Although ERPF and ERBF decreased after flunixin meglumine administration, the difference was not statistically significant.

  6. Videos Go Viral | Transportation Research | NREL

    Science.gov Websites

    and in Space NREL research makes lithium-ion batteries safer for earthlings and astronauts . Meet Matt , converters, and chargers-to control the flow of electricity between the battery, the motor, and other

  7. Techno-Economic, Sustainability, and Market Analysis | Bioenergy | NREL

    Science.gov Websites

    Techno-Economic, Sustainability, and Market Analysis Techno-Economic, Sustainability, and Market Analysis NREL conducts techno-economic analyses (TEAs) for algal biofuels, thermochemical conversion, and agitating the liquid as it flows around. Algal Biofuels Techno-Economic Analysis NREL's Algae Techno

  8. ACHP | Section 106 Regulations Users Guide

    Science.gov Websites

    related rules, policy issues, opinions, and guidance documents Section 106: The Rules Regulations Text Flow Chart and Explanatory Material Section-by-Section Questions and Answers Policy Statements ACHP Policy Statement on Historic Preservation and Community Revitalization Policy Statement on the ACHP's

  9. Comparison of radial 4D Flow-MRI with perivascular ultrasound to quantify blood flow in the abdomen and introduction of a porcine model of pre-hepatic portal hypertension.

    PubMed

    Frydrychowicz, A; Roldan-Alzate, A; Winslow, E; Consigny, D; Campo, C A; Motosugi, U; Johnson, K M; Wieben, O; Reeder, S B

    2017-12-01

    Objectives of this study were to compare radial time-resolved phase contrast magnetic resonance imaging (4D Flow-MRI) with perivascular ultrasound (pvUS) and to explore a porcine model of acute pre-hepatic portal hypertension (PHTN). Abdominal 4D Flow-MRI and pvUS in portal and splenic vein, hepatic and both renal arteries were performed in 13 pigs of approximately 60 kg. In six pigs, measurements were repeated after partial portal vein (PV) ligature. Inter- and intra-reader comparisons and statistical analysis including Bland-Altman (BA) comparison, paired Student's t tests and linear regression were performed. PvUS and 4D Flow-MRI measurements agreed well; flow before partial PV ligature was 322 ± 30 ml/min in pvUS and 297 ± 27 ml/min in MRI (p = 0.294), and average BA difference was 25 ml/min [-322; 372]. Inter- and intra-reader results differed very little, revealed excellent correlation (R 2  = 0.98 and 0.99, respectively) and resulted in BA differences of -5 ml/min [-161; 150] and -2 ml/min [-28; 25], respectively. After PV ligature, PV flow decreased from 356 ± 50 to 298 ± 61 ml/min (p = 0.02), and hepatic arterial flow increased from 277 ± 36 to 331 ± 65 ml/min (p = n.s.). The successful in vivo comparison of radial 4D Flow-MRI to perivascular ultrasound revealed good agreement of abdominal blood flow although with considerable spread of results. A model of pre-hepatic PHTN was successfully introduced and acute responses monitored. • Radial 4D Flow-MRI in the abdomen was successfully compared to perivascular ultrasound. • Inter- and intra-reader testing demonstrated excellent reproducibility of upper abdominal 4D Flow-MRI. • A porcine model of acute pre-hepatic portal hypertension was successfully introduced. • 4D Flow-MRI successfully monitored acute changes in a model of portal hypertension.

  10. [Digital blood flow measurement by venous occlusion plethysmography in Raynaud's phenomenon. Value of the rewarming test].

    PubMed

    Cristol, R; Debray, J

    1986-01-01

    The fingertip blood flow measured by mercury strain gauge plethysmography with venous occlusion, at 22 degrees C room temperature, had significantly lower mean values in 190 patients with Raynaud's phenomenon (55 men aged 49 yrs +/- 16, 135 women aged 48 yrs +/- 16) than in 40 age and sex matched controls: 18 ml/100 ml/minute +/- 14.6 versus 35 ml/100 ml/minute +/- 15 at level p less than 0.01. The mean fingertip blood flow was significantly lower (p less than 0.01) in 31 cases of scleroderma and 32 cases of pulpar necrosis (respectively 13 ml +/- 13 and 11 ml +/- 8) than in 55 cases of primary Raynaud's disease (no detectable etiology and normal capillaroscopy 5 years after onset) or in 34 cases of mild Raynaud's phenomenon (respectively 21.6 +/- 16 and 24.4 +/- 18). A warming test (both hands in water at 45 degrees C during 3 minutes) was performed in 50 cases with low basal fingertip blood flow. It induced a "normalized" flow in 22 cases (mostly primary or mild Raynaud), a partly improved flow in 20 cases (mostly secondary Raynaud) and no improvement in 8 cases (scleroderma). The warming test appears to be clinically useful to assess the vasospasm and the vasodilating capabilities.

  11. Blood flow measurement using digital subtraction angiography for assessing hemodialysis access function

    NASA Astrophysics Data System (ADS)

    Koirala, Nischal; Setser, Randolph M.; Bullen, Jennifer; McLennan, Gordon

    2017-03-01

    Blood flow rate is a critical parameter for diagnosing dialysis access function during fistulography where a flow rate of 600 ml/min in arteriovenous graft or 400-500 ml/min in arteriovenous fistula is considered the clinical threshold for fully functioning access. In this study, a flow rate computational model for calculating intra-access flow to evaluate dialysis access patency was developed and validated in an in vitro set up using digital subtraction angiography. Flow rates were computed by tracking the bolus through two regions of interest using cross correlation (XCOR) and mean arrival time (MAT) algorithms, and correlated versus an in-line transonic flow meter measurement. The mean difference (mean +/- standard deviation) between XCOR and in-line flow measurements for in vitro setup at 3, 6, 7.5 and 10 frames/s was 118+/-63 37+/-59 31+/-31 and 46+/-57 ml/min respectively while for MAT method it was 86+/-56 57+/-72 35+/-85 and 19+/-129 ml/min respectively. The result of this investigation will be helpful for selecting candidate algorithms while blood flow computational tool is developed for clinical application.

  12. New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

    NASA Technical Reports Server (NTRS)

    Qin, J. J.; Jones, M.; Shiota, T.; Greenberg, N. L.; Firstenberg, M. S.; Tsujino, H.; Zetts, A. D.; Sun, J. P.; Cardon, L. A.; Odabashian, J. A.; hide

    2000-01-01

    AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, P<0.05). CONCLUSION: Apically rotated measurement methods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

  13. Anh To | NREL

    Science.gov Websites

    pyrolysis vapors Catalytic depolymerization of biomass Process scale-up for catalyst synthesis and testing continuous flow reactors (gas & liquid phases) Catalyst synthesis: zeolites, supported metals, and

  14. Solidification structures grown under induced flow and continuous casting of steel

    NASA Technical Reports Server (NTRS)

    Tsavaras, A. A.

    1984-01-01

    The use of induced flow as a means to control solidification structures in strand cast steel is investigated. The quality problems in strand cast steel stemming from columnar growth can be partially controlled, by Electro Magnetic Stirring (EMS). Induced flow changes the normal morphology of dendrites. Solids grown under intense stirring conditions show both negative and positive segregation which is considered unacceptable by some steel producers. The inclusion size and population is strongly affected by induced flow (EMS). Laboratory and industrial data show substantial reduction in inclusion size and content, but the overall effect of flow on inclusions is affected by the particular type of flow patterns utilized in each case. Productivity and quality are raised substantially in steel strand casting by utilizing EMS.

  15. Energy Efficient Window Coatings that Please the Eye - Continuum Magazine

    Science.gov Websites

    voltage polarity reverses the lithium-ion flow, decreasing the glass tint and allowing more light to be transparent contact layers bookending a counterelectrode layer, ion-conducting layer, and electrochromic layer . Low voltage applied across the stacked layers causes lithium ions to migrate out of the

  16. Fermilab Today

    Science.gov Websites

    Search GO Special Result of the Week Toward a high-intensity muon source Impact of a single pulse of 12 x moment of impact (T=0); b) 9ms after impact; c) 15ms after impact. To solve the mysteries of nature 1012 protons at 14 GeV on a 1cm-wide jet of mercury flowing at 15m/s in a 10T solenoid field: a) at the

  17. Xiangkun Li | NREL

    Science.gov Websites

    Xiangkun Li Xiangkun Li Engineer - Energy Optimization Modeling Xiangkun.Li@nrel.gov | 303-275-4372 focus areas include renewable energy integration, energy systems optimization, and power flow modeling

  18. Impact of membrane lung surface area and blood flow on extracorporeal CO2 removal during severe respiratory acidosis.

    PubMed

    Karagiannidis, Christian; Strassmann, Stephan; Brodie, Daniel; Ritter, Philine; Larsson, Anders; Borchardt, Ralf; Windisch, Wolfram

    2017-12-01

    Veno-venous extracorporeal CO 2 removal (vv-ECCO 2 R) is increasingly being used in the setting of acute respiratory failure. Blood flow rates through the device range from 200 ml/min to more than 1500 ml/min, and the membrane surface areas range from 0.35 to 1.3 m 2 . The present study in an animal model with similar CO 2 production as an adult patient was aimed at determining the optimal membrane lung surface area and technical requirements for successful vv-ECCO 2 R. Four different membrane lungs, with varying lung surface areas of 0.4, 0.8, 1.0, and 1.3m 2 were used to perform vv-ECCO 2 R in seven anesthetized, mechanically ventilated, pigs with experimentally induced severe respiratory acidosis (pH 7.0-7.1) using a 20Fr double-lumen catheter with a sweep gas flow rate of 8 L/min. During each experiment, the blood flow was increased stepwise from 250 to 1000 ml/min. Amelioration of severe respiratory acidosis was only feasible when blood flow rates from 750 to 1000 ml/min were used with a membrane lung surface area of at least 0.8 m 2 . Maximal CO 2 elimination was 150.8 ml/min, with pH increasing from 7.01 to 7.30 (blood flow 1000 ml/min; membrane lung 1.3 m 2 ). The membrane lung with a surface of 0.4 m 2 allowed a maximum CO 2 elimination rate of 71.7 mL/min, which did not result in the normalization of pH, even with a blood flow rate of 1000 ml/min. Also of note, an increase of the surface area above 1.0 m 2 did not result in substantially higher CO 2 elimination rates. The pressure drop across the oxygenator was considerably lower (<10 mmHg) in the largest membrane lung, whereas the smallest revealed a pressure drop of more than 50 mmHg with 1000 ml blood flow/min. In this porcine model, vv-ECCO 2 R was most effective when using blood flow rates ranging between 750 and 1000 ml/min, with a membrane lung surface of at least 0.8 m 2 . In contrast, low blood flow rates (250-500 ml/min) were not sufficient to completely correct severe respiratory acidosis, irrespective of the surface area of the membrane lung being used. The converse was also true, low surface membrane lungs (0.4 m 2 ) were not capable of completely correcting severe respiratory acidosis across the range of blood flows used in this study.

  19. High-performance liquid chromatography study of gatifloxacin and sparfloxacin using erythrosine as post-column resonance Rayleigh scattering reagent and mechanism study.

    PubMed

    Pan, Ziyu; Peng, Jingdong; Zang, Xu; Peng, Huanjun; Xiao, Huan; Bu, Lingli; Chen, Fang; He, Yan; Chen, Yu; Wang, Xiang; Li, Shiyu; Chen, Yi

    2018-03-01

    Herein, a highly selective high-performance liquid chromatography (HPLC) coupled with resonance Rayleigh scattering (RRS) method was developed to detect gatifloxacin (GFLX) and sparfloxacin (SPLX). GFLX and SPLX were first separated by HPLC, then, in pH 4.4 Britton-Robinson (BR) buffer medium, protonic quaternary ammonia cation of GFLX and SPLX reacted with erythrosine (ERY) to form 1:1 ion-association complexes, which resulted in a significant enhancement of RRS signal. The experimental conditions of HPLC and post-column RRS have been investigated, including detection wavelength, flow rate, pH, reacting tube length and reaction temperature. Reaction mechanism were studied in detail by calculating the distribution fraction. The maximum RRS signals for GFLX and SPLX were recorded at λ ex  = λ em  = 330 nm. The detection limits were 3.8 ng ml -1 for GFLX and 17.5 ng ml -1 for SPLX at a signal-to-noise ratio of 3. The developed method was successfully applied to the determination of GFLX and SPLX in water samples. Recoveries from spiked water samples were 97.56-98.85%. Copyright © 2017 John Wiley & Sons, Ltd.

  20. Jennifer N. Markham | NREL

    Science.gov Websites

    -economic analysis Algae cultivation and separation Biomass conversion to fuels and higher values products economic modeling Discounted cash flow rate of return (DCFROR) Capital expenses Operating expense Education ;Techno-Economic Analysis for Upgrading Normal-Butanol to Jet and Hydrocarbon Fuel," presented at

  1. ACHP | Section 106 Regulations Flow Chart

    Science.gov Websites

    undertaking/no potential to cause effects Undertaking is type that might affect historic properties Identify No historic properties affected Historic properties are affected Assess Adverse Effects Apply affected Resolve Adverse Effects Continue consultation Memorandum of Agreement FAILURE TO AGREE COUNCIL

  2. Research | Energy Systems Integration Facility | NREL

    Science.gov Websites

    levels of variable supply and demand? How do we keep the lights on and the fuel flowing in a world of , regulatory frameworks, and value propositions for consumers in this changing world? NREL's crosscutting Partner with our world-class researchers Work

  3. Water Power | NREL

    Science.gov Websites

    Regulations Publications WEC3: Wave Energy Converter Code Comparison Project Turbine Control of a Tidal and Surge Wave Energy Converter Performance Characterization of a Cross-Flow Hydrokinetic Turbine in Sheared Inflow More publications News News More News New Wave Energy Converter Design Inspired by Wind Energy

  4. High-Performance Algorithms and Complex Fluids | Computational Science |

    Science.gov Websites

    only possible by combining experimental data with simulation. Capabilities Capabilities include: Block -laden, non-Newtonian, as well as traditional internal and external flows. Contact Ray Grout Group

  5. Ryan King | NREL

    Science.gov Websites

    research focuses on optimization and machine learning applied to complex energy systems and turbulent flows techniques to improve wind plant design and controls and developed a new data-driven machine learning closure

  6. Influence of infusion volume on the ocular hemodynamic effects of peribulbar anesthesia.

    PubMed

    Lung, Solveig; Luksch, Alexandra; Weigert, Günther; Georgopoulos, Michael; Menapace, Rupert; Polska, Elzbieta; Garhofer, Gerhard; Findl, Oliver; Schmetterer, Leopold

    2006-09-01

    To test the hypothesis that ocular blood-flow response to peribulbar anesthesia can be reduced by using a smaller volume of anesthetic mixture. Departments of Ophthalmology and Clinical Pharmacology, Medical University of Vienna, Vienna, Austria. Twenty patients scheduled for bilateral age-related cataract surgery were enrolled in a prospective randomized balanced observer-masked crossover study. Two study days with a 2 mL injection volume or 5 mL injection volume used for peribulbar anesthesia were scheduled. On 1 study day, patients received the 1-dose regimen and on the other study day, when the contralateral eye had surgery, patients received the other injection volume. On both study days, the anesthetic mixture consisted of an equal amount of lidocaine, bupivacaine, and hyaluronidase independently of the injection volume. Intraocular pressure (IOP), blood pressure, and pulse rate were measured noninvasively. Ocular fundus pulsation amplitude (FPA) and peak systolic and end diastolic flow velocities in the central retinal artery were measured with laser interferometry and color Doppler imaging, respectively. The results were recorded as means +/- SD. Peribulbar anesthesia increased IOP and reduced FPA and flow velocities in the central retinal artery. The effects on IOP (5 mL, 35.1% +/- 16.0%; 2 mL, 14.1% +/- 14.1%; P<.001) and ocular hemodynamic parameters (FPA: 5 mL, -17.5% +/- 7.8%/2 mL, -7.3% +/- 7.2%, P<.001; peak systolic velocity: 5 mL, -19.5% +/- 10.7%/2 mL, -10.6% +/- 9.8%, P = .013; end diastolic velocity: 5 mL, -16.7% +/- 6.2%/2 mL, -8.4% +/- 7.3%, P = .005) were more pronounced with the 5 mL injection volume than with the 2 mL injection volume. An injection volume of 2 mL instead of 5 mL reduced the ocular blood-flow response to peribulbar anesthesia. This procedure may be used in patients with ocular vascular disease to reduce the incidence of anesthesia-induced ischemia and loss of vision.

  7. Thomas Gennett | NREL

    Science.gov Websites

    catalysts through ion implantation and sputtering Non-aqueous flow batteries based on organic energy-storage organic radical polymer in the solid state," Journal of Physical Chemistry C (2015) 119(37), 21369 . Braunecker, T.W. Kemper, R.E. Larsen, T. Gennett, "Close packing of nitroxide radicals in stable organic

  8. Safety Sensor Testing Laboratory | Hydrogen and Fuel Cells | NREL

    Science.gov Websites

    collaborations, trainings and workshops, and academic research and development support. Work in the laboratory (temperature, pressure, and relative humidity) and gas parameters (flow and composition) Quantitative sensor services to assist end-users on sensor selection and use Assist developers in quantitative assessment of

  9. ACHP | News

    Science.gov Websites

    structures that will be used to support fixed wireless antennas within the existing railroad right of way alongside existing tracks. The antennas are used to support the wireless flow of information needed for the : Steve DelSordo, Federal Preservation Officer of the FCC Wireless Telecommunications Bureau at (202) 418

  10. Guide to Geologic Hazards in Alaska | Alaska Division of Geological &

    Science.gov Websites

    content Guide to Geologic Hazards in Alaska Glossary Coastal and river hazards image Coastal and river Storm surge Tsunami Earthquake related hazards image Earthquake related hazards Earthquake Earthquake Subsidence Surface fault rupture Tsunami Uplift Glacier hazards image Glacier hazards Avalanche Debris flow

  11. Acute effects of using an electronic nicotine-delivery device (electronic cigarette) on myocardial function: comparison with the effects of regular cigarettes.

    PubMed

    Farsalinos, Konstantinos E; Tsiapras, Dimitris; Kyrzopoulos, Stamatis; Savvopoulou, Maria; Voudris, Vassilis

    2014-06-23

    Electronic cigarettes have been developed and marketed in recent years as smoking substitutes. However, no studies have evaluated their effects on the cardiovascular system. The purpose of this study was to examine the immediate effects of electronic cigarette use on left ventricular (LV) function, compared to the well-documented acute adverse effects of smoking. Echocardiographic examinations were performed in 36 healthy heavy smokers (SM, age 36 ± 5 years) before and after smoking 1 cigarette and in 40 electronic cigarette users (ECIG, age 35 ± 5 years) before and after using the device with "medium-strength" nicotine concentration (11 mg/ml) for 7 minutes. Mitral flow diastolic velocities (E, A), their ratio (E/A), deceleration time (DT), isovolumetric relaxation time (IVRT) and corrected-to-heart rate IVRT (IVRTc) were measured. Mitral annulus systolic (Sm), and diastolic (Em, Am) velocities were estimated. Myocardial performance index was calculated from Doppler flow (MPI) and tissue Doppler (MPIt). Longitudinal deformation measurements of global strain (GS), systolic (SRs) and diastolic (SRe, SRa) strain rate were also performed. Baseline measurements were similar in both groups. In SM, IVRT and IVRTc were prolonged, Em and SRe were decreased, and both MPI and MPIt were elevated after smoking. In ECIG, no differences were observed after device use. Comparing after-use measurements, ECIG had higher Em (P = 0.032) and SRe (P = 0.022), and lower IVRTc (P = 0.011), MPI (P = 0.001) and MPIt (P = 0.019). The observed differences were significant even after adjusting for changes in heart rate and blood pressure. Although acute smoking causes a delay in myocardial relaxation, electronic cigarette use has no immediate effects. Electronic cigarettes' role in tobacco harm reduction should be studied intensively in order to determine whether switching to electronic cigarette use may have long-term beneficial effects on smokers' health. Current Controlled Trials ISRCTN16974547.

  12. Unstimulated salivary flow rate, pH and buffer capacity of saliva in healthy volunteers.

    PubMed

    Fenoll-Palomares, C; Muñoz Montagud, J V; Sanchiz, V; Herreros, B; Hernández, V; Mínguez, M; Benages, A

    2004-11-01

    To assess the salivary flow rate, pH, and buffer capacity of healthy volunteers, and their relationships with age, gender, obesity, smoking, and alcohol consumption, and to establish the lower-end value of normal salivary flow (oligosialia). A prospective study was conducted in 159 healthy volunteers (age > 18 years, absence of medical conditions that could decrease salivary flow). Unstimulated whole saliva was collected during ten minutes, and salivary flow rate (ml/min), pH, and bicarbonate concentration (mmol/l) were measured using a Radiometer ABL 520. The 5 percentile of salivary flow rate and bicarbonate concentration was considered the lower limit of normality. Median salivary flow rate was 0.48 ml/min (range: 0.1-2 ml/min). Age younger than 44 years was associated with higher flow rates (OR 2.10). Compared with women, men presented a higher flow rate (OR 3.19) and buffer capacity (OR 2.81). Bicarbonate concentration correlated with salivary flow rate. The lower-end values of normal flow rate and bicarbonate concentration were 0.15 ml/min and 1.800 mmol/l, respectively. The presence of obesity, smoking, and alcohol consumption did not influence salivary parameters. In healthy volunteers, salivary flow rate depends on age and gender, and correlates with buffer capacity. Obesity, smoking, and alcohol use do not influence salivary secretion.

  13. Nonlinear evolution of the Kelvin-Helmholtz instability in the double current sheet configuration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mao, Aohua; Li, Jiquan, E-mail: lijq@energy.kyoto-u.ac.jp; Kishimoto, Yasuaki

    2016-03-15

    The nonlinear evolution of the Kelvin-Helmholtz (KH) instability driven by a radially antisymmetric shear flow in the double current sheet configuration is numerically investigated based on a reduced magnetohydrodynamic model. Simulations reveal different nonlinear fate of the KH instability depending on the amplitude of the shear flow, which restricts the strength of the KH instability. For strong shear flows far above the KH instability threshold, the linear electrostatic-type KH instability saturates and achieves a vortex flow dominated quasi-steady state of the electromagnetic (EM) KH turbulence with large-amplitude zonal flows as well as zonal fields. The magnetic surfaces are twisted significantlymore » due to strong vortices but without the formation of magnetic islands. However, for the shear flow just over the KH instability threshold, a weak EM-type KH instability is saturated and remarkably damped by zonal flows through modifying the equilibrium shear flow. Interestingly, a secondary double tearing mode (DTM) is excited subsequently in highly damped KH turbulence, behaving as a pure DTM in a flowing plasma as described in Mao et al. [Phys. Plasmas 21, 052304 (2014)]. However, the explosive growth phenomenon is replaced by a gradually growing oscillation due to the extremely twisted islands. As a result, the release of the magnetic energy becomes slow and the global magnetic reconnection tends to be gentle. A complex nonlinear interaction between the EM KH turbulence and the DTMs occurs for the medium shear flows above the KH instability threshold, turbulent EM fluctuations experience oscillatory nonlinear growth of the DTMs, finally achieves a quasi-steady state with the interplay of the fluctuations between the DTMs and the EM KH instability.« less

  14. Alternative Fuels Data Center: How Do All-Electric Cars Work?

    Science.gov Websites

    charge while charging the pack. Power electronics controller: This unit manages the flow of electrical of the engine, electric motor, power electronics, and other components. Traction battery pack: Stores

  15. Materials Flow through Industry Supply Chain Modeling Tool | Advanced

    Science.gov Websites

    efficiency. It also performs supply chain scale analyses to quantify the impacts and benefits of next , read Evaluating opportunities to improve material and energy impacts in commodity supply chains

  16. Analytical Methods for Interconnection | Distributed Generation

    Science.gov Websites

    ; ANALYSIS Program Lead Kristen.Ardani@nrel.gov 303-384-4641 Accurately and quickly defining the effects of designed to accommodate voltage rises, bi-directional power flows, and other effects caused by distributed

  17. A fluidics comparison of Alcon Infiniti, Bausch & Lomb Stellaris, and Advanced Medical Optics Signature phacoemulsification machines.

    PubMed

    Georgescu, Dan; Kuo, Annie F; Kinard, Krista I; Olson, Randall J

    2008-06-01

    To compare three phacoemulsification machines for measurement accuracy and postocclusion surge (POS) in human cadaver eyes. In vitro comparisons of machine accuracy and POS. Tip vacuum and flow were compared with machine indicated vacuum and flow. All machines were placed in two human cadaver eyes and POS was determined. Vacuum (% of actual) was 101.9% +/- 1.7% for Infiniti (Alcon, Fort Worth, Texas, USA), 93.2% +/- 3.9% for Stellaris (Bausch & Lomb, Rochester, New York, USA), and 107.8% +/- 4.6% for Signature (Advanced Medical Optics, Santa, Ana, California, USA; P < .0001). At 60 ml/minute flow, actual flow and unoccluded flow vacuum (UFV) was 55.8 +/- 0.4 ml/minute and 197.7 +/- 0.7 mm Hg for Infiniti, 53.5 +/- 0.0 ml/minute and 179.8 +/- 0.9 mm Hg for Stellaris, and 58.5 +/- 0.0 ml/minute and 115.1 +/- 2.3 mm Hg for Signature (P < .0001). POS in an 32-year-old eye was 0.33 +/- 0.05 mm for Infiniti, 0.16 +/- 0.06 mm for Stellaris, and 0.13 +/- 0.04 mm for Signature at 550 mm Hg, 60 cm bottle height, 45 ml/minute flow with 19-gauge tips (P < .0001 for Infiniti vs Stellaris and Signature). POS in an 81-year-old eye was 1.51 +/- 0.22 mm for Infiniti, 0.83 +/- 0.06 mm for Stellaris, 0.67 +/- 0.01 mm for Signature at 400 mm Hg vacuum, 70 cm bottle height, 40 ml/minute flow with 19-gauge tips (P < .0001). Machine-indicated accuracy, POS, and UFV were statistically significantly different. Signature had the lowest POS and vacuum to maintain flow. Regarding POS, Stellaris was close to Signature; regarding vacuum to maintain flow, Infiniti and Stellaris were similar. Minimizing POS and vacuum to maintain flow potentially are important in avoiding ocular damage and surgical complications.

  18. A new Doppler-echo method to quantify regurgitant volume.

    PubMed

    Wang, S S; Rubenstein, J J; Goldman, M; Sidd, J J

    1992-01-01

    An in vitro technique using color flow imaging and continuous wave Doppler was developed to measure the initial regurgitant flow jet diameter and velocity integral to yield the parameters for a volume calculation. Jets were produced by volume-controlled injection through tubes of various diameters (1.3, 1.9, 2.8, and 3.5 mm) to deliver volumes from 1 to 7 ml over 100 to 300 msec at pressures from 40 to 200 mm Hg. One hundred forty-five samples were obtained. Flow jet diameter consistently overestimated tube diameter by 2 mm when injected volume was 1.5 to 7 ml and by 1.5 mm when injected volume was less than 1.5 ml. This offset was stable with various transducers (2.5, 3.5, 5.0 MHz) at normal gain setting (just under noise). Therefore, corrected flow jet diameter (FJD) = FJD - 2 mm, and Doppler volume = corrected flow jet area x velocity integral. A range of injectates from 1.1 to 7 ml generated Doppler volume of 1.0 to 8.2 ml. The relation between Doppler volume (DV) and injected volume (IV) was DV = 1.079 IV - 0.22, r2 = 0.945, p less than 0.01. This relation was not altered by tube diameter. Thus a method combining color flow imaging and continuous wave Doppler provides a reliable and accurate measure of in vitro flow volume.

  19. The additional benefit of the ML Flow test to classify leprosy patients.

    PubMed

    Bührer-Sékula, Samira; Illarramendi, Ximena; Teles, Rose B; Penna, Maria Lucia F; Nery, José Augusto C; Sales, Anna Maria; Oskam, Linda; Sampaio, Elizabeth P; Sarno, Euzenir N

    2009-08-01

    The use of the skin lesion counting classification leads to both under and over diagnosis of leprosy in many instances. Thus, there is a need to complement this classification with another simple and robust test for use in the field. Data of 202 untreated leprosy patients diagnosed at FIOCRUZ, Rio de Janeiro, Brazil, was analyzed. There were 90 patients classified as PB and 112 classified as MB according to the reference standard. The BI was positive in 111 (55%) patients and the ML Flow test in 116 (57.4%) patients. The ML Flow test was positive in 95 (86%) of the patients with a positive BI. The lesion counting classification was confirmed by both BI and ML Flow tests in 65% of the 92 patients with 5 or fewer lesions, and in 76% of the 110 patients with 6 or more lesions. The combination of skin lesion counting and the ML Flow test results yielded a sensitivity of 85% and a specificity of 87% for MB classification, and correctly classified 86% of the patients when compared to the standard reference. A considerable proportion of the patients (43.5%) with discordant test results in relation to standard classification was in reaction. The use of any classification system has limitations, especially those that oversimplify a complex disease such as leprosy. In the absence of an experienced dermatologist and slit skin smear, the ML Flow test could be used to improve treatment decisions in field conditions.

  20. Ultra-Sensitive Biological Detection via Nanoparticle-Based Magnetically Amplified Surface Plasmon Resonance (Mag-SPR) Techniques

    DTIC Science & Technology

    2008-10-08

    of reactant to ferrocene and xylene, a liquid carbon source, results in longer nanostructures in larger amount as shown in Fig. 2(g). These samples...with 6.5 mol% ferrocene and 100 mol% xylene. The flow rate was (e) 0.195 ml/hr, (f) 0.98 ml/hr, and (g) 1.95 ml/hr. (d) and (h) are HR-TEM images of...and ferrocene . The flow rate was (a) 0.195 ml/hr and (b) 1.95 ml/hr........................ 19  Fig. A-5. STEM EDS analysis of the CF specimen after

  1. Full Hybrid: Cruising

    Science.gov Websites

    for storage. Go back… stage graphic: vertical blue rule Main stage: See through car with battery , engine, generator, power split device, and electric motor visible. The car is moving. There are arrows flowing from the gasoline engine to the generator to the battery. Main stage: See through car with battery

  2. Full Hybrid: Low Speed

    Science.gov Websites

    blue rule Main stage: See through car with battery, engine, generator, power split device, and electric motor visible. The car is moving at a low speed. There are arrows flowing from the battery to the electric motor to the power split device to the front wheels. Main stage: See through car with battery

  3. Hybrid: Braking

    Science.gov Websites

    motor slows the vehicle down. Go to next… stage graphic: vertical blue rule Main stage: See through car with battery, engine, and electric motor visible. The car is decelerating. There are arrows flowing from the front wheels to the electric motor to the battery. Main stage: See through car with battery

  4. Zion's New Visitor Center a Model of Energy Efficiency

    Science.gov Websites

    million people a year visit the park, overwhelming the scenic canyon with traffic, frustrating park-goers comes in through clerestory and other windows. When there is not enough sunlight, the building's energy the windows from the summer sun. When the clerestory windows are open, cooler air naturally flows

  5. Full Hybrid: Passing

    Science.gov Websites

    additional power is needed, the gasoline engine and electric motor are both used to propel the vehicle. Go to , power split device, and electric motor visible while passing another vehicle. There are purple arrows flowing from the generator to the electric motor to the power split device to the front wheels. There are

  6. Collaborations Move Industry Forward, Prove Mutually Beneficial | News |

    Science.gov Websites

    features collaboration between NREL and GE Global Research, which is advancing its use of NREL's Simulator researchers to better understand wind farm flow physics so future wind farms can be more optimally designed Colorado will join in interpreting the data. "Wind farm control is garnering interest across the

  7. Guangdong Zhu | NREL

    Science.gov Websites

    Guangdong.Zhu@nrel.gov | 303-275-4497 Guangdong joined the Thermal Systems Group at NREL in 2010 and is working collectors is performed. He is also involved in optical and thermal modeling and economic analysis of solar , and presentations in the areas of multiphase flow, power generation systems, and solar thermal power

  8. Biotechnology Process Engineering Center at MIT - Overview

    Science.gov Websites

    ADVISORY BOARD Under an academic paradigm set forth by the National Science Foundation for National Engineering Research Centers, BPEC exists as a partnership with industry. Regular two-way information flow sabbaticals at MIT and student internships at our industrial partners. We have selected an elite group of

  9. Effects of Nitroglycerin on Regional Myocardial Blood Flow in Coronary Artery Disease

    PubMed Central

    Horwitz, Lawrence D.; Gorlin, Richard; Taylor, Warren J.; Kemp, Harvey G.

    1971-01-01

    Regional myocardial blood flow before and after sublingual nitroglycerin was measured in 10 patients with coronary artery disease. During thoracotomy, 133Xe was injected directly into the subepicardium in diseased regions of the anterior left ventricular wall, and washout rates were recorded with a scintillation counter. All disappearance curves were closely approximated by two exponential decays analyzed as two parallel flow systems by the compartmental method. The appearance of a double exponential decay pattern in diseased regions suggests that the slow phase was associated with collateral blood flow, although nonhomogeneous myocardium-to-blood partition coefficients for xenon cannot be excluded. Nitroglycerin increased the rapid phase flow in 9 of 10 patients and the slow flow in 7 of 10 patients. Average flow increased in 9 of the 10 patients (P < 0.01). Mean rapid phase flow in the control state was 110 ml/100 g per min and after nitroglycerin increased to 132 ml/100 g per min (P < 0.01); slow phase flow increased from 12 ml/100 g per min to 15 ml/100 g per min (P < 0.05). It is concluded that, under these conditions, nitroglycerin improves perfusion in regions of diseased myocardium in patients with coronary artery disease. PMID:4999635

  10. Alternative Fuels Data Center: How Do Plug-In Hybrid Electric Cars Work?

    Science.gov Websites

    the pack. Power electronics controller: This unit manages the flow of electrical energy delivered by , electric motor, power electronics, and other components. Traction battery pack: Stores electricity for use

  11. Webcam-based flow cytometer using wide-field imaging for low cell number detection at high throughput.

    PubMed

    Balsam, Joshua; Bruck, Hugh Alan; Rasooly, Avraham

    2014-09-07

    Here we describe a novel low-cost flow cytometer based on a webcam capable of low cell number detection in a large volume which may overcome the limitations of current flow cytometry. Several key elements have been combined to yield both high throughput and high sensitivity. The first element is a commercially available webcam capable of 187 frames per second video capture at a resolution of 320 × 240 pixels. The second element in this design is a 1 W 450 nm laser module for area-excitation, which combined with the webcam allows for rapid interrogation of a flow field. The final element is a 2D flow-cell which overcomes the flow limitation of hydrodynamic focusing and allows for higher sample throughput in a wider flow field. This cell allows for the linear velocity of target cells to be lower than in a conventional "1D" hydrodynamic focusing flow-cells typically used in cytometry at similar volumetric flow rates. It also allows cells to be imaged at the full frame rate of the webcam. Using this webcam-based flow cytometer with wide-field imaging, it was confirmed that the detection of fluorescently tagged 5 μm polystyrene beads in "1D" hydrodynamic focusing flow-cells was not practical for low cell number detection due to streaking from the motion of the beads, which did not occur with the 2D flow-cell design. The sensitivity and throughput of this webcam-based flow cytometer was then investigated using THP-1 human monocytes stained with SYTO-9 florescent dye in the 2D flow-cell. The flow cytometer was found to be capable of detecting fluorescently tagged cells at concentrations as low as 1 cell per mL at flow rates of 500 μL min(-1) in buffer and in blood. The effectiveness of detection was concentration dependent: at 100 cells per mL 84% of the cells were detected compared to microscopy, 10 cells per mL 79% detected and 1 cell per mL 59% of the cells were detected. With the blood samples spiked to 100 cells per mL, the average concentration for all samples was 91.4 cells per mL, with a 95% confidence interval of 86-97 cells per mL. These low cell concentrations and the large volume capabilities of the system may overcome the limitations of current cytometry, and are applicable to rare cell (such as circulating tumor cell) detection The simplicity and low cost of this device suggests that it may have a potential use in developing point-of-care clinical flow cytometry for resource-poor settings associated with global health.

  12. Assessment of blood flow with 68Ga-DOTA PET in experimental inflammation: a validation study using 15O-water

    PubMed Central

    Autio, Anu; Saraste, Antti; Kudomi, Nobuyuki; Saanijoki, Tiina; Johansson, Jarkko; Liljenbäck, Heidi; Tarkia, Miikka; Oikonen, Vesa; Sipilä, Hannu T; Roivainen, Anne

    2014-01-01

    Increased blood flow and vascular permeability are key events in inflammation. Based on the fact that Gadolinium-1,4,7,10-tetraazacyclododecane-N,N‘,N‘‘,N‘‘‘-tetraacetic acid (Gd-DOTA) is commonly used in magnetic resonance (MR) imaging of blood flow (perfusion), we evaluated the feasibility of its Gallium-68 labeled DOTA analog (68Ga-DOTA) for positron emission tomography (PET) imaging of blood flow in experimental inflammation. Adult, male Sprague-Dawley rats with turpentine oil induced sterile skin/muscle inflammation were anesthetized with isoflurane, and imaged under rest and adenosine-induced hyperemia by means of dynamic 2-min Oxygen-15 labeled water (H2 15O) and 30-min 68Ga-DOTA PET. For the quantification of PET data, regions of interest (ROIs) were defined in the focus of inflammation, healthy muscle, myocardium and heart left ventricle. Radioactivity concentration in the ROIs versus time after injection was determined for both tracers and blood flow was calculated using image-derived input. According to the H2 15O PET, blood flow was 0.69 ± 0.15 ml/min/g for inflammation and 0.15 ± 0.03 ml/min/g for muscle during rest. The blood flow remained unchanged during adenosine-induced hyperemia 0.67 ± 0.11 and 0.12 ± 0.03 ml/min/g for inflammation and muscle, respectively, indicating that adenosine has little effect on blood flow in peripheral tissues in rats. High focal uptake of 68Ga-DOTA was seen at the site of inflammation throughout the 30-min PET imaging. According to the 68Ga-DOTA PET, blood flow measured as the blood-to-tissue transport rate (K1) was 0.60 ± 0.07 ml/min/g for inflammation and 0.14 ± 0.06 ml/min/g for muscle during rest and 0.63 ± 0.08 ml/min/g for inflammation and 0.09 ± 0.04 ml/min/g for muscle during adenosine-induced hyperemia. The H2 15O-based blood flow and 68Ga-DOTA-based K1 values correlated well (r = 0.94, P < 0.0001). These results show that 68Ga-DOTA PET imaging is useful for the quantification of increased blood flow induced by inflammation. PMID:25250206

  13. Assessment of blood flow with (68)Ga-DOTA PET in experimental inflammation: a validation study using (15)O-water.

    PubMed

    Autio, Anu; Saraste, Antti; Kudomi, Nobuyuki; Saanijoki, Tiina; Johansson, Jarkko; Liljenbäck, Heidi; Tarkia, Miikka; Oikonen, Vesa; Sipilä, Hannu T; Roivainen, Anne

    2014-01-01

    Increased blood flow and vascular permeability are key events in inflammation. Based on the fact that Gadolinium-1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid (Gd-DOTA) is commonly used in magnetic resonance (MR) imaging of blood flow (perfusion), we evaluated the feasibility of its Gallium-68 labeled DOTA analog ((68)Ga-DOTA) for positron emission tomography (PET) imaging of blood flow in experimental inflammation. Adult, male Sprague-Dawley rats with turpentine oil induced sterile skin/muscle inflammation were anesthetized with isoflurane, and imaged under rest and adenosine-induced hyperemia by means of dynamic 2-min Oxygen-15 labeled water (H2 (15)O) and 30-min (68)Ga-DOTA PET. For the quantification of PET data, regions of interest (ROIs) were defined in the focus of inflammation, healthy muscle, myocardium and heart left ventricle. Radioactivity concentration in the ROIs versus time after injection was determined for both tracers and blood flow was calculated using image-derived input. According to the H2 (15)O PET, blood flow was 0.69 ± 0.15 ml/min/g for inflammation and 0.15 ± 0.03 ml/min/g for muscle during rest. The blood flow remained unchanged during adenosine-induced hyperemia 0.67 ± 0.11 and 0.12 ± 0.03 ml/min/g for inflammation and muscle, respectively, indicating that adenosine has little effect on blood flow in peripheral tissues in rats. High focal uptake of (68)Ga-DOTA was seen at the site of inflammation throughout the 30-min PET imaging. According to the (68)Ga-DOTA PET, blood flow measured as the blood-to-tissue transport rate (K1) was 0.60 ± 0.07 ml/min/g for inflammation and 0.14 ± 0.06 ml/min/g for muscle during rest and 0.63 ± 0.08 ml/min/g for inflammation and 0.09 ± 0.04 ml/min/g for muscle during adenosine-induced hyperemia. The H2 (15)O-based blood flow and (68)Ga-DOTA-based K1 values correlated well (r = 0.94, P < 0.0001). These results show that (68)Ga-DOTA PET imaging is useful for the quantification of increased blood flow induced by inflammation.

  14. Effects of electrical muscle stimulation on oxygen consumption.

    PubMed

    Hayter, Tina L; Coombes, Jeff S; Knez, Wade L; Brancato, Tania L

    2005-02-01

    Electrical muscle stimulation (EMS) devices are being marketed as weight/ fat loss devices throughout the world. Commercially available stimulators have the ability to evoke muscle contractions that may affect caloric expenditure while the device is being used. The aim of this study was to test the effects of two different EMS devices (Abtronic and Feminique) on oxygen consumption at rest. Subjects arrived for testing after an overnight fast, had the devices fitted, and then positioned supine with expired air measured to determine oxygen consumption. After a 10-minute acclimation period, oxygen consumption was measured for 20 minutes with the device switched off (resting) then 20 minutes with the device switched on (stimulated). There were no significant differences (p > 0.05) in oxygen consumption between the resting and stimulated periods with either the Abtronic (mean +/- SD; resting, 3.40 +/- 0.44; stimulated, 3.45 +/- 0.53 ml of O(2).kg(-1).min(-1)) or the Feminique (resting, 3.73 +/- 0.45; stimulated, 3.75 +/- 0.46 ml of O(2).kg(-1).min(-1)). In summary, the EMS devices tested had no effect on oxygen consumption during muscle stimulation.

  15. Omeprazole hydroxylation is inhibited by a single dose of moclobemide in homozygotic EM genotype for CYP2C19.

    PubMed

    Cho, Joo-Youn; Yu, Kyung-Sang; Jang, In-Jin; Yang, Byung-Hwan; Shin, Sang-Goo; Yim, Dong-Seok

    2002-04-01

    The pharmacokinetics of omeprazole and its metabolites in healthy subjects were evaluated to determine if a single dose of moclobemide inhibited CYP2C19 activity. Sixteen volunteers, of whom eight were extensive metabolizers (EM) and eight were poor metabolizers for CYP2C19, participated in two studies. Venous blood samples were collected for 24 h after oral ingestion of 40 mg omeprazole with or without 300 mg moclobemide coadministration. The pharmacokinetic change of omeprazole, omeprazole sulphone and 5-hydroxyomeprazole concentrations were assessed to test for an interaction between omeprazole and moclobemide. The coadministration of moclobemide in EMs approximately doubled the mean AUC (from 1834 to 3760 ng ml(-1) h) and C(max) (from 987 to 1649 ng ml(-1)) of omeprazole, and increased the AUC of omeprazole sulphone without changing AUC ratio of omeprazole to omeprazole sulphone. Moclobemide coadministration more than doubled the AUC ratio of omeprazole to 5-hydroxyomeprazole (from 2.5 to 5.3) in EMs, too. There was a significant decrease in Cmax and AUC of 5-hydroxyomeprazole in PMs but no significant changes were seen in the results for omeprazole and omeprazole sulphone AUCs. A single dose of moclobemide resulted in significant suppression of CYP2C19 activity in EMs. We conclude that physicians prescribing moclobemide should pay attention to its pharmacokinetic interactions even on the first day of coadministration with CYP2C19 substrates.

  16. Slow climate velocities of mountain streams portend their role as refugia

    Science.gov Websites

    result in imprecise estimates of network extent and flow dynamics (41). The problem is most acute in radiation-induced xerostomia by protecting salivary stem cells from toxic aldehydes Show more Ecology

  17. NREL to Research Revolutionary Battery Storage Approaches in Support of

    Science.gov Websites

    adoption by dramatically improving driving range and reliability, and by providing low-cost carbon have the potential to meet the demanding safety, cost and performance levels for EVs set by ARPA-E, but materials to develop a new low-cost battery that operates similar to a flow battery, where chemical energy

  18. Alternative Fuels Data Center: Electricity Research and Development

    Science.gov Websites

    blades of a turbine connected to an electric generator. The turbine generator set converts mechanical and solar thermal, the heat that is produced is used to create steam, which moves the blades of the turbine. In the cases of hydropower and wind power, turbine blades are moved directly by flowing water and

  19. Colin A. McMillan | NREL

    Science.gov Websites

    Colin A. McMillan Photo of Colin A. McMillan. Colin McMillan Researcher IV-Operations Research Econometrics Research Interests Systems-level energy efficiency analysis Material and energy flows in economies ; Journal of Industrial Ecology 17, no. 5 (October 2013): 700-11. doi:10.1111/jiec.12050 McMillan, C.A., S.J

  20. NOAA's world-class weather and climate prediction center opens at

    Science.gov Websites

    StumbleUpon Digg More Destinations NOAA's world-class weather and climate prediction center opens at currents and large-scale rain and snow storms. Billions of earth observations from around the world flow operations. Investing in this center is an investment in our human capital, serving as a world class facility

  1. NOAA Photo Library - Beginnings and Endings

    Science.gov Websites

    Collections page. Takes you to the search page. Takes you to the Links page. collage featuring setting sun celebration of sun, sky, clouds, and horizon. Revel in shades of red, pink, orange, and blue. End your visit at sunset Alaska red sky with sun Atlantic ocean scene at sunrise with ice flows Antarctic moon over

  2. Intraoperative coronary grafts flow measurement using the TTFM flowmeter: results from a domestic sample.

    PubMed

    Succi, José Ernesto; Gerola, Luis Roberto; Succi, Guilherme de Menezes; Kim, Hyong Chun; Paredes, Jorge Edwin Morocho; Bufollo, Enio

    2012-01-01

    To evaluate intraoperative graft patency and identify grafts under risk of early occlusion. Fifty four patients were submitted to coronary artery bypass surgery and the graft flow was assessed by the Flowmeter (Medtronic Medistim), which utilizes the TTFM method. Three patients had left main disease and 48 had normal or mildly reduced left ventricular function. In hospital mortality was 3.7% (two patients), one for mesenteric thrombosis and one due to cardiogenic chock. Seventeen patients (34%) were submitted to off pump CABG. Arterial Graft flow measures ranged from 8 to 106 ml/min (average 31.14 ml/min), and venous grafts flow ranged from 9 to 149 ml/min (average 50.42 ml/min). Flowmeter use represents higher safety both for patients and surgeons. Even under legal aspects, the documentation provided by the device can avoid future questionings.

  3. Flow Components in a NaK Test Loop Designed to Simulate Conditions in a Nuclear Surface Power Reactor

    NASA Astrophysics Data System (ADS)

    Polzin, Kurt A.; Godfroy, Thomas J.

    2008-01-01

    A test loop using NaK as the working fluid is presently in use to study material compatibility effects on various components that comprise a possible nuclear reactor design for use on the lunar surface. A DC electromagnetic (EM) pump has been designed and implemented as a means of actively controlling the NaK flow rate through the system and an EM flow sensor is employed to monitor the developed flow rate. These components allow for the matching of the flow rate conditions in test loops with those that would be found in a full-scale surface-power reactor. The design and operating characteristics of the EM pump and flow sensor are presented. In the EM pump, current is applied to a set of electrodes to produce a Lorentz body force in the fluid. A measurement of the induced voltage (back-EMF) in the flow sensor provides the means of monitoring flow rate. Both components are compact, employing high magnetic field strength neodymium magnets thermally coupled to a water-cooled housing. A vacuum gap limits the heat transferred from the high temperature NaK tube to the magnets and a magnetically-permeable material completes the magnetic circuit. The pump is designed to produce a pressure rise of 34.5 kPa, and the flow sensor's predicted output is roughly 20 mV at the loop's nominal flow rate of 0.114 m3/hr.

  4. Flow Components in a NaK Test Loop Designed to Simulate Conditions in a Nuclear Surface Power Reactor

    NASA Technical Reports Server (NTRS)

    Polzin, Kurt A.; Godfroy, Thomas J.

    2008-01-01

    A test loop using NaK as the working fluid is presently in use to study material compatibility effects on various components that comprise a possible nuclear reactor design for use on the lunar surface. A DC electromagnetic (EM) pump has been designed and implemented as a means of actively controlling the NaK flow rate through the system and an EM flow sensor is employed to monitor the developed flow rate. These components allow for the matching of the flow rate conditions in test loops with those that would be found in a full-scale surface-power reactor. The design and operating characteristics of the EM pump and flow sensor are presented. In the EM pump, current is applied to a set of electrodes to produce a Lorentz body force in the fluid. A measurement of the induced voltage (back-EMF) in the flow sensor provides the means of monitoring flow rate. Both components are compact, employing high magnetic field strength neodymium magnets thermally coupled to a water-cooled housing. A vacuum gap limits the heat transferred from the high temperature NaK tube to the magnets and a magnetically-permeable material completes the magnetic circuit. The pump is designed to produce a pressure rise of 5 psi, and the flow sensor's predicted output is roughly 20 mV at the loop's nominal flow rate of 0.5 GPM.

  5. Myocardial Blood Flow and Inflammatory Cardiac Sarcoidosis.

    PubMed

    Kruse, Matthew J; Kovell, Lara; Kasper, Edward K; Pomper, Martin G; Moller, David R; Solnes, Lilja; Chen, Edward S; Schindler, Thomas H

    2017-02-01

    This study sought to evaluate the effects of inflammatory sarcoid disease on coronary circulatory function and the response to immune-suppressive treatment. Although positron emission tomography assessment of myocardial inflammation is increasingly applied to identify active cardiac sarcoidosis, its effect on coronary flow and immune-suppressive treatment remains to be characterized. Thirty-two individuals, who were referred for positron emission tomography/computed tomography, were evaluated for known or suspected cardiac sarcoidosis applying 18 F-fluorodeoxyglucose to determine inflammation and 13 N-ammonia to assess for perfusion deficits following a high-fat/low-carbohydrate diet and fasting state >12 h to suppress myocardial glucose uptake. Inflammation was quantified with standardized uptake value and regional myocardial blood flow at rest and during regadenoson-stimulated hyperemia was determined in ml/g/min. Positron emission tomography studies were repeated in 18 cases with a median follow-up of 2.5 years (interquartile range [IQR]:1.3 to 3.4 years). Twenty-five exams had normal perfusion but evidence of regional inflammation (group 1), and 21 exams presented a regional perfusion deficit associated with inflammation (group 2). Median myocardial blood flow did not differ between inflamed and noninflamed myocardium in both groups (0.86 ml/g/min [IQR: 0.66 to 1.11 ml/g/min] vs. 0.83 ml/g/min [IQR: 0.64 to 1.12 ml/g/min] and 0.74 ml/g/min [IQR: 0.60 to 0.93 ml/g/min] vs. 0.77 ml/g/min [IQR: 0.59 to 0.95 ml/g/min], respectively). As regards median hyperemic myocardial blood flows, they were significantly lower in the inflamed than in the remote regions in group 1 and 2 (2.31 ml/g/min [IQR: 1.81 to 2.95 ml/g/min] vs. 2.70 ml/g/min [IQR: 2.07 to 3.30 ml/g/min] and 1.61 ml/g/min [IQR: 1.17 to 2.18 ml/g/min] vs. 1.94 ml/g/min [IQR: 1.49 to 2.39 ml/g/min]; p < 0.001, respectively). Immune-suppression-mediated decrease in inflammation was associated with preserved myocardial flow reserve (MFR) at follow-up, whereas MFR significantly worsened in regions without changes or even increases in inflammation (median ΔMFR: 0.07 [IQR: -0.29 to 0.45] vs. -0.24 [IQR: -0.84 to 0.21]; p < 0.001). There was an inverse correlation between pronounced alterations in myocardial inflammation (Δ regional myocardial volume with standardized uptake value >4.1) and ΔMFR (r = -0.47; p = 0.048). Sarcoid-mediated myocardial inflammation is associated with a regional impairment of coronary circulatory function. The association between immune-suppressive treatment-related alterations in myocardial inflammation and changes in coronary vasodilator capacity suggests direct adverse effect of inflammation on coronary circulatory function in cardiac sarcoidosis. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Using archived ITS data to measure the operational benefits of a system-wide adaptive ramp metering system : appendix online 5 : I-205 NB ramp flow & ML speed-flow plots.

    DOT National Transportation Integrated Search

    2008-12-01

    The appendix includes various ramp flow and ML speed-flow plots, including: I-205 NB, Gladstone MP 11.05; I-205 NB, Gladstone Hway MP 12.94; I-205 NB, Lawnfield MP 13.58; I-205 NB, Sunnybrook MP 14.32; I-205 NB, Sunnyside MP 14.7; I-205 NB, Johnson C...

  7. Electrical conduction disturbance effects on dynamic changes of functional mitral regurgitation.

    PubMed

    Fukuda, Shota; Grimm, Richard; Song, Jong-Min; Kihara, Takashi; Daimon, Masao; Agler, Deborah A; Wilkoff, Bruce L; Natale, Andrea; Thomas, James D; Shiota, Takahiro

    2005-12-20

    The aim of this study was to investigate the relationship between dynamics of functional mitral regurgitation (MR) and the degree of electrical conduction disturbance, and to evaluate the impact of cardiac resynchronization therapy (CRT) on MR severity and its phasic pattern. Mechanisms of phasic changes of functional MR, which may be determined by annulus dilation and tethering of the leaflet, remain unclear. Transthoracic two-dimensional echocardiography was performed in 60 patients with functional MR. A biventricular pacemaker was implanted in 19 patients. The mitral annulus area (MAA) and the tenting area (TA) were measured from apical views. The MR volume and fraction were assessed by the quantitative pulsed Doppler method. Instantaneous regurgitation flow rate was measured by proximal flow convergence method. A dynamic change in MR flow rate was evaluated by frame-by-frame analysis throughout systole. A phasic pattern with two peaks at early- and late-systole and decrease in mid-systole was noticed in 57 patients. The early-systolic peak of MR was larger than the late-systolic peak (128.4 +/- 64.3 ml/s vs. 73.9 +/- 55.1 ml/s, p < 0.001). The ratio of flow rate at these two peaks correlated with QRS duration (r = 0.55, p < 0.001). Early-systolic flow rate reduced after CRT (143.9 +/- 60.8 ml/s to 90.7 +/- 54.1 ml/s, p < 0.05), but late-systolic flow rate did not (61.5 +/- 55.0 ml/s to 51.2 +/- 40.9 ml/s, p = NS). A similar pattern was observed for TA, whereas MAA did not change after CRT. Biphasic pattern was found in functional MR, and the ratio of flow rate at two peaks correlated with QRS duration. The CRT decreased regurgitation flow volume by reducing early-systolic MR but not late-systolic MR, resulting in the change in phasic pattern of functional MR.

  8. Mathematical Model for Collision-Coalescence Among Inclusions in the Bloom Continuous Caster with M-EMS

    NASA Astrophysics Data System (ADS)

    Lei, Hong; Jiang, Jimin; Yang, Bin; Zhao, Yan; Zhang, Hongwei; Wang, Weixian; Dong, Guiwen

    2018-04-01

    Mathematical simulation is an effective tool to analyze the fluid flow and the inclusion behavior in the bloom continuous caster with mold electromagnetic stirring (M-EMS). The mathematical model is applied to the modeling of magnetic field, flow field, and inclusion field. Due to the introduction of Archimedes force, the collision mechanism and inclusion's slipping velocity should be modified in the inclusion mass and population conservation model. Numerically predicted magnetic field, flow field, and the inclusion spatial distribution conform to the experimental results in the existing literature. Lorentz force plays an important role in the fluid flow, and Archimedes force plays an important role in the inclusion distribution in the continuous caster. Due to Brownian collision, Stokes collision, Archimedes collision, and turbulent collision, the coalescence among inclusions occurs in the bloom continuous caster with M-EMS. Among the four types of collisions, turbulent collision occurs most frequently, followed by Archimedes collision and Stokes collision. The frequency of Brownian collision is several orders of magnitudes smaller and is therefore negligible. The inclusion volume concentration, number density, and characteristic radius exhibit a U-shape in the continuous caster without M-EMS. However, with M-EMS, they exhibit an inverted U-shape.

  9. Increased plasma soluble adhesion molecules; ICAM-1, VCAM-1, and E-selectin levels in patients with slow coronary flow.

    PubMed

    Turhan, Hasan; Saydam, Gul Sevim; Erbay, Ali Riza; Ayaz, Selime; Yasar, Ayse Saatci; Aksoy, Yuksel; Basar, Nurcan; Yetkin, Ertan

    2006-04-04

    Inflammation has been reported to be a major contributing factor to many cardiovascular events. In the present study, we aimed to evaluate plasma soluble adhesion molecules; intercellular adhesion molecule-1 (ICAM-1), vascular cell adhesion molecule-1 (VCAM-1) and E-selectin as possible indicators of endothelial activation or inflammation in patients with slow coronary flow. Study population included 17 patients with angiographically proven normal coronary arteries and slow coronary flow in all three coronary vessels (group I, 11 male, 6 female, mean age=48+/-9 years), and 20 subjects with angiographically proven normal coronary arteries without associated slow coronary flow (group II, 11 male, 9 female, mean age=50+/-8 years). Coronary flow rates of all patients and control subjects were documented by Thrombolysis In Myocardial Infarction frame count (TIMI frame count). All patients in group I had TIMI frame counts greater than two standard deviation above those of control subjects (group II) and, therefore, were accepted as exhibiting slow coronary flow. Serum levels of ICAM-1, VCAM-1, and E-selectin were measured in all patients and control subjects using commercially available ELISA kits. Serum ICAM-1, VCAM-1, and E-selectin levels of patients with slow coronary flow were found to be significantly higher than those of control subjects with normal coronary flow (ICAM-1: 545+/-198 ng/ml vs. 242+/-113 ng/ml respectively, p<0.001, VCAM-1: 2040+/-634 ng/ml vs. 918+/-336 ng/ml respectively, p<0.001, E-selectin: 67+/-9 ng/ml vs. 52+/-8 ng/ml respectively, p<0.001). Average TIMI frame count was detected to be significantly correlated with plasma soluble ICAM-1 (r=0.550, p<0.001), VCAM-1 (r=0.569, p<0.001) and E-selectin (r=0.443, p=0.006). Increased levels of soluble adhesion molecules in patients with slow coronary flow may be an indicator of endothelial activation and inflammation and are likely to be in the causal pathway leading to slow coronary flow.

  10. Effect of antiischemic therapy on coronary flow reserve and the pressure-maximal coronary flow relationship in anesthetized swine.

    PubMed

    McFalls, E O; Duncker, D J; Sassen, L M; Gho, B C; Verdouw, P D

    1991-12-01

    The effect of nifedipine (0.5, 1.0, and 2.0 micrograms/kg/min), metoprolol (0.1, 0.5, and 1.0 mg/kg), the beta 1-selective adrenoceptor partial agonist epanolol (10, 50, and 200 micrograms/kg), or equivalent volumes of isotonic saline (n = 6, in each group), on coronary blood flow capacity were studied in anesthetized swine. Intracoronary bolus injections of adenosine (20 micrograms/kg/0.2 ml) were administered without and during three levels of coronary stenosis, prior to and following each dose of drug, to obtain maximal coronary blood flows at different perfusion pressures in the autoregulatory range. Coronary perfusion pressures were varied by partial inflation of a balloon around the left anterior descending coronary artery. Special care was taken that the stenoses not lead to myocardial ischemia. Three indices of coronary blood flow capacity were used: absolute coronary flow reserve (ACFR, the ratio of maximal to resting coronary blood flow), the slope and the extrapolated pressure at zero flow (Pzf) of the pressure-maximal coronary flow (PMCF) relationship, and relative coronary flow reserve (RCFR, the ratio of maximal coronary blood flow with a stenosis to maximal coronary blood flow without a stenosis) at two of the three levels of stenosis. Nifedipine decreased ACFR from 4.5 +/- 1.9 to 1.9 +/- 0.3 (mean +/- SD; p less than 0.05), reflecting in part the increase in resting coronary blood flow. The nifedipine-induced changes in maximal coronary blood flow were not only due to a drop in perfusion pressure, as the slope of the PMCF relationship decreased from 2.27 +/- 0.49 ml/(min.mm Hg) to 1.54 +/- 0.51 ml/(min.mm Hg) (p less than 0.05), and Pzf decreased from 30 +/- 4 mm Hg to 20 +/- 7 mm Hg (p less than 0.05). Consequently, calculated maximal coronary blood flow was attenuated from 114 +/- 31 ml/min to 93 +/- 37 ml/min at 80 mm Hg, but was enhanced from 23 +/- 13 to 37 +/- 24 ml/min at 40 mm Hg coronary perfusion pressure. In concert with the change in the PMCF relationship, RCFR at equivalent severe stenosis increased from 0.33 +/- 0.06 to 0.47 +/- 0.10 (p less than 0.05). No changes were observed with metoprolol, epanolol, or saline. The effect of nifedipine on the PMCF relationship not only provides a mechanism for the drug's antiischemic action, but should also be considered in the interpretation of coronary flow reserve measurements in patients on nifedipine treatment.

  11. WaterML: an XML Language for Communicating Water Observations Data

    NASA Astrophysics Data System (ADS)

    Maidment, D. R.; Zaslavsky, I.; Valentine, D.

    2007-12-01

    One of the great impediments to the synthesis of water information is the plethora of formats used to publish such data. Each water agency uses its own approach. XML (eXtended Markup Languages) are generalizations of Hypertext Markup Language to communicate specific kinds of information via the internet. WaterML is an XML language for water observations data - streamflow, water quality, groundwater levels, climate, precipitation and aquatic biology data, recorded at fixed, point locations as a function of time. The Hydrologic Information System project of the Consortium of Universities for the Advancement of Hydrologic Science, Inc (CUAHSI) has defined WaterML and prepared a set of web service functions called WaterOneFLow that use WaterML to provide information about observation sites, the variables measured there and the values of those measurments. WaterML has been submitted to the Open GIS Consortium for harmonization with its standards for XML languages. Academic investigators at a number of testbed locations in the WATERS network are providing data in WaterML format using WaterOneFlow web services. The USGS and other federal agencies are also working with CUAHSI to similarly provide access to their data in WaterML through WaterOneFlow services.

  12. The calcium paradox phenomenon: a flow rate and volume response study of calcium-free perfusion.

    PubMed

    Oksendal, A N; Jynge, P; Sellevold, O F; Rotevatn, S; Saetersdal, T

    1985-10-01

    A dose-response study concerning the importance of the flow rate (0.5 to 12 ml/min) and volume (2.5 to 60 ml) of calcium-free coronary perfusion (duration 5 min) in the induction of a calcium paradox on reperfusion (duration 15 min) with calcium-containing medium has been performed in the isolated rat heart (37 degrees C). On the basis of enzymatic, physiological, and metabolic assessments three different levels of tissue injury were identified: a minimal paradox at 1.0 ml/min or 5 ml, a subtotal paradox at 2 ml/min or 10 ml and a total paradox at 9 ml/min or 45 ml. Ultrastructural examination revealed that cellular injury following calcium repletion was always severe, and that an increase in the flow rate and volume of calcium-free perfusion increased the number of severely injured cells. During calcium-free perfusion the external lamina largely remained intact over the surface coat of the sarcolemma, but variable degrees of separation of intercalated discs were observed. It is concluded that the calcium paradox model of myocardial injury presents a rather sharp threshold related to the flow rate or volume of calcium-free coronary perfusion and that on trespassing this threshold there is a narrow zone characterized by a decreasing number of viable cells. Furthermore, the study indicates that a separation of the external lamina from the surface coat of the sarcolemma is not a prerequisite for the induction of a calcium paradox, and that cell injury may occur in the presence of intact intercalated discs.

  13. Novel monorail infusion catheter for volumetric coronary blood flow measurement in humans: in vitro validation.

    PubMed

    van 't Veer, Marcel; Adjedj, Julien; Wijnbergen, Inge; Tóth, Gabor G; Rutten, Marcel C M; Barbato, Emanuele; van Nunen, Lokien X; Pijls, Nico H J; De Bruyne, Bernard

    2016-08-20

    The aim of this study is to validate a novel monorail infusion catheter for thermodilution-based quantitative coronary flow measurements. Based on the principles of thermodilution, volumetric coronary flow can be determined from the flow rate of a continuous saline infusion, the temperature of saline when it enters the coronary artery, and the temperature of the blood mixed with the saline in the distal part of the coronary artery. In an in vitro set-up of the systemic and coronary circulation at body temperature, coronary flow values were varied from 50-300 ml/min in steps of 50 ml/min. At each coronary flow value, thermodilution-based measurements were performed at infusion rates of 15, 20, and 30 ml/min. Temperatures and pressures were simultaneously measured with a pressure/temperature sensor-tipped guidewire. Agreement of the calculated flow and the measured flow as well as repeatability were assessed. A total of five catheters were tested, with a total of 180 measurements. A strong correlation (ρ=0.976, p<0.0001) and a difference of -6.5±15.5 ml/min were found between measured and calculated flow. The difference between two repeated measures was 0.2%±8.0%. This novel infusion catheter used in combination with a pressure/temperature sensor-tipped guidewire allows accurate and repeatable absolute coronary flow measurements. This opens a window to a better understanding of the coronary microcirculation.

  14. Crystal Solar and NREL Team Up to Cut Costs | News | NREL

    Science.gov Websites

    throughput and half the cost could be a game-changer, creating American jobs and stemming the flow of solar , as a way of making it cost competitive with fossil-fuel-based electricity. Incubator Program at NREL cost of the final PV product." Solar Wafers at 13 Cents per Watt Photo of three men. Enlarge image

  15. Diabetic patients have abnormal cerebral autoregulation during cardiopulmonary bypass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Croughwell, N.; Lyth, M.; Quill, T.J.

    1990-11-01

    We tested the hypothesis that insulin-dependent diabetic patients with coronary artery bypass graft surgery experience altered coupling of cerebral blood flow and oxygen consumption. In a study of 23 patients (11 diabetics and 12 age-matched controls), cerebral blood flow was measured using 133Xe clearance during nonpulsatile, alpha-stat blood gas managed cardiopulmonary bypass at the conditions of hypothermia and normothermia. In diabetic patients, the cerebral blood flow at 26.6 +/- 2.42 degrees C was 25.3 +/- 14.34 ml/100 g/min and at 36.9 +/- 0.58 degrees C it was 27.3 +/- 7.40 ml/100 g/min (p = NS). The control patients increased cerebralmore » blood flow from 20.7 +/- 6.78 ml/100 g/min at 28.4 +/- 2.81 degrees C to 37.6 +/- 8.81 ml/100 g/min at 36.5 +/- 0.45 degrees C (p less than or equal to 0.005). The oxygen consumption was calculated from jugular bulb effluent and increased from hypothermic values of 0.52 +/- 0.20 ml/100 g/min in diabetics to 1.26 +/- 0.28 ml/100 g/min (p = 0.001) at normothermia and rose from 0.60 +/- 0.27 to 1.49 +/- 0.35 ml/100 g/min (p = 0.0005) in the controls. Thus, despite temperature-mediated changes in oxygen consumption, diabetic patients did not increase cerebral blood flow as metabolism increased. Arteriovenous oxygen saturation gradients and oxygen extraction across the brain were calculated from arterial and jugular bulb blood samples. The increase in arteriovenous oxygen difference between temperature conditions in diabetic patients and controls was significantly different (p = 0.01). These data reveal that diabetic patients lose cerebral autoregulation during cardiopulmonary bypass and compensate for an imbalance in adequate oxygen delivery by increasing oxygen extraction.« less

  16. The performance of monotonic and new non-monotonic gradient ascent reconstruction algorithms for high-resolution neuroreceptor PET imaging.

    PubMed

    Angelis, G I; Reader, A J; Kotasidis, F A; Lionheart, W R; Matthews, J C

    2011-07-07

    Iterative expectation maximization (EM) techniques have been extensively used to solve maximum likelihood (ML) problems in positron emission tomography (PET) image reconstruction. Although EM methods offer a robust approach to solving ML problems, they usually suffer from slow convergence rates. The ordered subsets EM (OSEM) algorithm provides significant improvements in the convergence rate, but it can cycle between estimates converging towards the ML solution of each subset. In contrast, gradient-based methods, such as the recently proposed non-monotonic maximum likelihood (NMML) and the more established preconditioned conjugate gradient (PCG), offer a globally convergent, yet equally fast, alternative to OSEM. Reported results showed that NMML provides faster convergence compared to OSEM; however, it has never been compared to other fast gradient-based methods, like PCG. Therefore, in this work we evaluate the performance of two gradient-based methods (NMML and PCG) and investigate their potential as an alternative to the fast and widely used OSEM. All algorithms were evaluated using 2D simulations, as well as a single [(11)C]DASB clinical brain dataset. Results on simulated 2D data show that both PCG and NMML achieve orders of magnitude faster convergence to the ML solution compared to MLEM and exhibit comparable performance to OSEM. Equally fast performance is observed between OSEM and PCG for clinical 3D data, but NMML seems to perform poorly. However, with the addition of a preconditioner term to the gradient direction, the convergence behaviour of NMML can be substantially improved. Although PCG is a fast convergent algorithm, the use of a (bent) line search increases the complexity of the implementation, as well as the computational time involved per iteration. Contrary to previous reports, NMML offers no clear advantage over OSEM or PCG, for noisy PET data. Therefore, we conclude that there is little evidence to replace OSEM as the algorithm of choice for many applications, especially given that in practice convergence is often not desired for algorithms seeking ML estimates.

  17. Lymphatic pump treatment increases thoracic duct lymph flow in conscious dogs with edema due to constriction of the inferior vena cava.

    PubMed

    Prajapati, Parna; Shah, Pankhil; King, Hollis H; Williams, Arthur G; Desai, Pratikkumar; Downey, H Fred

    2010-09-01

    Osteopathic lymphatic pump treatments (LPT) are used to treat edema, but their direct effects on lymph flow have not been studied. In the current study, we examined the effects of LPT on lymph flow in the thoracic duct of instrumented conscious dogs in the presence of edema produced by constriction of the inferior vena cava (IVC). Six dogs were surgically instrumented with an ultrasonic flow transducer on the thoracic lymph duct and catheters in the descending thoracic aorta and in IVC. After postoperative recovery, lymph flow and hemodynamic variables were measured 1) pre-LPT, 2) during 4 min LPT, 3) post-LPT, in the absence and presence of edema produced by IVC constriction. This constriction increased abdominal girth from 60 +/-2.6 to 75 +/- 2.9 cm. Before IVC constriction, LPT increased lymph flow (P < 0.05) from 1.9 +/- 0.2 ml/min to a maximum of 4.7 +/-1.2 ml/min, whereas after IVC constriction, LPT increased lymph flow (P < 0.05) from 7.9 +/-2.2 to a maximum of 11.7 +/-2.2 ml/min. The incremental lymph flow mobilized by 4 min of LPT (ie, the flow that exceeded 4 min of baseline flow), was 10.6 ml after IVC constriction. This incremental flow was not significantly greater than that measured before IVC constriction. Edema caused by IVC constriction markedly increased lymph flow in the thoracic duct. LPT increased thoracic duct lymph flow before and after IVC constriction. The lymph flow mobilized by 4 min of LPT in presence of edema was not significantly greater than that mobilized prior to edema.

  18. MTBE BIODEGRADATION IN A GRAVITY FLOW, HIGH-BIOMASS RETAINING BIOREACTOR

    EPA Science Inventory

    The aerobic biodegradation of methyl tert-butyl ether (MtBE), a widely used fuel oxygenate, was investigated using a pilot-scale biomass-retaining bioreactor called a Biomass Concentrator Reactor (BCR). The reactor was operated for a year at a flow rate of 2500 L/d on Ci...

  19. Renal cortical and medullary blood flow responses to altered NO availability in humans.

    PubMed

    Damkjær, Mads; Vafaee, Manoucher; Møller, Michael L; Braad, Poul Erik; Petersen, Henrik; Høilund-Carlsen, Poul Flemming; Bie, Peter

    2010-12-01

    The objective of this study was to quantify regional renal blood flow in humans. In nine young volunteers on a controlled diet, the lower abdomen was CT-scanned, and regional renal blood flow was determined by positron emission tomography (PET) scanning using H(2)(15)O as tracer. Measurements were performed at baseline, during constant intravenous infusion of nitric oxide (NO) donor glyceryl nitrate and after intravenous injection of NO synthase inhibitor N(ω)-monomethyl-L-arginine (L-NMMA). Using the CT image, the kidney pole areas were delineated as volumes of interest (VOI). In the data analysis, tissue layers with a thickness of one voxel were eliminated stepwise from the external surface of the VOI (voxel peeling), and the blood flow subsequently was determined in each new, reduced VOI. Blood flow in the shrinking VOIs decreased as the number of cycles of voxel peeling increased. After 4-5 cycles, blood flow was not reduced further by additional voxel peeling. This volume-insensitive flow was measured to be 2.30 ± 0.17 ml·g tissue(-1)·min(-1) during the control period; it increased during infusion of glyceryl nitrate to 2.97 ± 0.18 ml·g tissue(-1)·min(-1) (P < 0.05) and decreased after L-NMMA injection to 1.57 ± 0.17 ml·g tissue(-1)·min(-1) (P < 0.05). Cortical blood flow was 4.67 ± 0.31 ml·g tissue(-1)·min(-1) during control, unchanged by glyceryl nitrate, and decreased after L-NMMA [3.48 ± 0.23 ml·(g·min)(-1), P < 0.05]. PET/CT scanning allows identification of a renal medullary region in which the measured blood flow is 1) low, 2) independent of reduction in the VOI, and 3) reactive to changes in systemic NO supply. The technique seems to provide indices of renal medullary blood flow in humans.

  20. Effect of air flow on tubular solar still efficiency

    PubMed Central

    2013-01-01

    Background An experimental work was reported to estimate the increase in distillate yield for a compound parabolic concentrator-concentric tubular solar still (CPC-CTSS). The CPC dramatically increases the heating of the saline water. A novel idea was proposed to study the characteristic features of CPC for desalination to produce a large quantity of distillate yield. A rectangular basin of dimension 2 m × 0.025 m × 0.02 m was fabricated of copper and was placed at the focus of the CPC. This basin is covered by two cylindrical glass tubes of length 2 m with two different diameters of 0.02 m and 0.03 m. The experimental study was operated with two modes: without and with air flow between inner and outer tubes. The rate of air flow was fixed throughout the experiment at 4.5 m/s. On the basis of performance results, the water collection rate was 1445 ml/day without air flow and 2020 ml/day with air flow and the efficiencies were 16.2% and 18.9%, respectively. Findings The experimental study was operated with two modes: without and with air flow between inner and outer tubes. The rate of air flow was fixed throughout the experiment at 4.5 m/s. Conclusions On the basis of performance results, the water collection rate was 1445 ml/day without air flow and 2020 ml/day with air flow and the efficiencies were 16.2% and 18.9%, respectively. PMID:23587020

  1. Effect of air flow on tubular solar still efficiency.

    PubMed

    Thirugnanasambantham, Arunkumar; Rajan, Jayaprakash; Ahsan, Amimul; Kandasamy, Vinothkumar

    2013-01-01

    An experimental work was reported to estimate the increase in distillate yield for a compound parabolic concentrator-concentric tubular solar still (CPC-CTSS). The CPC dramatically increases the heating of the saline water. A novel idea was proposed to study the characteristic features of CPC for desalination to produce a large quantity of distillate yield. A rectangular basin of dimension 2 m × 0.025 m × 0.02 m was fabricated of copper and was placed at the focus of the CPC. This basin is covered by two cylindrical glass tubes of length 2 m with two different diameters of 0.02 m and 0.03 m. The experimental study was operated with two modes: without and with air flow between inner and outer tubes. The rate of air flow was fixed throughout the experiment at 4.5 m/s. On the basis of performance results, the water collection rate was 1445 ml/day without air flow and 2020 ml/day with air flow and the efficiencies were 16.2% and 18.9%, respectively. THE EXPERIMENTAL STUDY WAS OPERATED WITH TWO MODES: without and with air flow between inner and outer tubes. The rate of air flow was fixed throughout the experiment at 4.5 m/s. On the basis of performance results, the water collection rate was 1445 ml/day without air flow and 2020 ml/day with air flow and the efficiencies were 16.2% and 18.9%, respectively.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    The purpose of the computer program is to generate system matrices that model data acquisition process in dynamic single photon emission computed tomography (SPECT). The application is for the reconstruction of dynamic data from projection measurements that provide the time evolution of activity uptake and wash out in an organ of interest. The measurement of the time activity in the blood and organ tissue provide time-activity curves (TACs) that are used to estimate kinetic parameters. The program provides a correct model of the in vivo spatial and temporal distribution of radioactive in organs. The model accounts for the attenuation ofmore » the internal emitting radioactivity, it accounts for the vary point response of the collimators, and correctly models the time variation of the activity in the organs. One important application where the software is being used in a measuring the arterial input function (AIF) in a dynamic SPECT study where the data are acquired from a slow camera rotation. Measurement of the arterial input function (AIF) is essential to deriving quantitative estimates of regional myocardial blood flow using kinetic models. A study was performed to evaluate whether a slowly rotating SPECT system could provide accurate AIF's for myocardial perfusion imaging (MPI). Methods: Dynamic cardiac SPECT was first performed in human subjects at rest using a Phillips Precedence SPECT/CT scanner. Dynamic measurements of Tc-99m-tetrofosmin in the myocardium were obtained using an infusion time of 2 minutes. Blood input, myocardium tissue and liver TACs were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K1. Results: The spatiotemporal 4D ML-EM reconstructions gave more accurate reconstructions that did standard frame-by-frame 3D ML-EM reconstructions. From additional computer simulations and phantom studies, it was determined that a 1 minute infusion with a SPECT system rotation speed providing 180 degrees of projection data every 54s can produce measurements of blood pool and myocardial TACs. This has important application in the circulation of coronary flow reserve using rest/stress dynamic cardiac SPECT. They system matrices are used in maximum likelihood and maximum a posterior formulations in estimation theory where through iterative algorithms (conjugate gradient, expectation maximization, or maximum a posteriori probability algorithms) the solution is determined that maximizes a likelihood or a posteriori probability function.« less

  3. Comparative Evaluation of Flow Quantification across the Atrioventricular Valve in Patients with Functional Univentricular Heart after Fontan's Surgery and Healthy Controls: Measurement by 4D Flow Magnetic Resonance Imaging and Streamline Visualization.

    PubMed

    She, Hoi Lam; Roest, Arno A W; Calkoen, Emmeline E; van den Boogaard, Pieter J; van der Geest, Rob J; Hazekamp, Mark G; de Roos, Albert; Westenberg, Jos J M

    2017-01-01

    To evaluate the inflow pattern and flow quantification in patients with functional univentricular heart after Fontan's operation using 4D flow magnetic resonance imaging (MRI) with streamline visualization when compared with the conventional 2D flow approach. Seven patients with functional univentricular heart after Fontan's operation and twenty-three healthy controls underwent 4D flow MRI. In two orthogonal two-chamber planes, streamline visualization was applied, and inflow angles with peak inflow velocity (PIV) were measured. Transatrioventricular flow quantification was assessed using conventional 2D multiplanar reformation (MPR) and 4D MPR tracking the annulus and perpendicular to the streamline inflow at PIV, and they were validated with net forward aortic flow. Inflow angles at PIV in the patient group demonstrated wide variation of angles and directions when compared with the control group (P < .01). The use of 4D flow MRI with streamlines visualization in quantification of the transatrioventricular flow had smaller limits of agreement (2.2 ± 4.1 mL; 95% limit of agreement -5.9-10.3 mL) when compared with the static plane assessment from 2DFlow MRI (-2.2 ± 18.5 mL; 95% limit of agreement agreement -38.5-34.1 mL). Stronger correlation was present in the 4D flow between the aortic and trans-atrioventricular flow (R 2 correlation in 4D flow: 0.893; in 2D flow: 0.786). Streamline visualization in 4D flow MRI confirmed variable atrioventricular inflow directions in patients with functional univentricular heart with previous Fontan's procedure. 4D flow aided generation of measurement planes according to the blood flood dynamics and has proven to be more accurate than the fixed plane 2D flow measurements when calculating flow quantifications. © 2016 Wiley Periodicals, Inc.

  4. SEASONAL VARIATIONS IN HUMAN PAROTID FLUID FLOW RATE IN A SUBTROPICAL CLIMATE.

    DTIC Science & Technology

    Parotid fluid was collected under conditions of very minimal stimulation from 3,868 systemically healthy young adult males over a period of two...calendar years. The study was carried out in a subtropical climate in which the only thermal discomfort resulted from the summer heat. Parotid flow rate...fall. During the summer months the mean rate of parotid flow was 0.031 ml./minute; during the winter the flow rate mean increased by 35% to 0.042 ml

  5. Using archived ITS data to measure the operational benefits of a system-wide adaptive ramp metering system : appendix online 10 : OR\\0x2010217 NB ramp flow & ML speed-flow plots.

    DOT National Transportation Integrated Search

    2008-12-01

    The appendix includes various ramp flow and ML speed-flow plots: OR-217 NB, 72nd MP 6.61; OR-217 NB, 99W-EB MP 5.9; OR-217 NB, 99W-WB MP 5.85; OR-217 NB, Greenburg MP 4.65; OR-217 NB, Scholls MP 3.85; OR-217 NB, Denney MP 2.68; OR-217 NB, Allen MP 2....

  6. Simultaneous maximum a posteriori longitudinal PET image reconstruction

    NASA Astrophysics Data System (ADS)

    Ellis, Sam; Reader, Andrew J.

    2017-09-01

    Positron emission tomography (PET) is frequently used to monitor functional changes that occur over extended time scales, for example in longitudinal oncology PET protocols that include routine clinical follow-up scans to assess the efficacy of a course of treatment. In these contexts PET datasets are currently reconstructed into images using single-dataset reconstruction methods. Inspired by recently proposed joint PET-MR reconstruction methods, we propose to reconstruct longitudinal datasets simultaneously by using a joint penalty term in order to exploit the high degree of similarity between longitudinal images. We achieved this by penalising voxel-wise differences between pairs of longitudinal PET images in a one-step-late maximum a posteriori (MAP) fashion, resulting in the MAP simultaneous longitudinal reconstruction (SLR) method. The proposed method reduced reconstruction errors and visually improved images relative to standard maximum likelihood expectation-maximisation (ML-EM) in simulated 2D longitudinal brain tumour scans. In reconstructions of split real 3D data with inserted simulated tumours, noise across images reconstructed with MAP-SLR was reduced to levels equivalent to doubling the number of detected counts when using ML-EM. Furthermore, quantification of tumour activities was largely preserved over a variety of longitudinal tumour changes, including changes in size and activity, with larger changes inducing larger biases relative to standard ML-EM reconstructions. Similar improvements were observed for a range of counts levels, demonstrating the robustness of the method when used with a single penalty strength. The results suggest that longitudinal regularisation is a simple but effective method of improving reconstructed PET images without using resolution degrading priors.

  7. Performance of three systems for warming intravenous fluids at different flow rates.

    PubMed

    Satoh, J; Yamakage, M; Wasaki, S I; Namiki, A

    2006-02-01

    This study compared the intravenous fluid warming capabilities of three systems at different flow rates. The devices studied were a water-bath warmer, a dry-heat plate warmer, and an intravenous fluid tube warmer Ambient temperature was controlled at 22 degrees to 24 degrees C. Normal saline (0.9% NaCl) at either room temperature (21 degrees to 23 degrees C) or at ice-cold temperature (3 degrees to 5 degrees C) was administered through each device at a range of flow rates (2 to 100 ml/min). To mimic clinical conditions, the temperature of the fluid was measured with thermocouples at the end of a one metre tube connected to the outflow of the warmer for the first two devices and at the end of the 1.2 m warming tubing for the intravenous fluid tube warmer The temperature of fluid delivered by the water bath warmer increased as the flow rate was increased up to 15 to 20 ml/min but decreased with greater flow rates. The temperature of the fluid delivered by the dry-heat plate warmer significantly increased as the flow rate was increased within the range tested (due to decreased cooling after leaving the device at higher flow rates). The temperature of fluid delivered by the intravenous fluid tube warmer did not depend on the flow rate up to 20 ml/min but significantly and fluid temperature-dependently decreased at higher flow rates (>30 ml/min). Under the conditions of our testing, the dry heat plate warmer delivered the highest temperature fluid at high flow rates.

  8. In vitro performance and principles of anti-siphoning devices.

    PubMed

    Freimann, Florian Baptist; Kimura, Takaoki; Stockhammer, Florian; Schulz, Matthias; Rohde, Veit; Thomale, Ulrich-Wilhelm

    2014-11-01

    Anti-siphon devices (ASDs) of various working principles were developed to overcome overdrainage-related complications associated with ventriculoperitoneal shunting. We aimed to provide comparative data on the pressure and flow characteristics of six different types of ASDs (gravity-assisted, membrane-controlled, and flow-regulated) in order to achieve a better understanding of these devices and their potential clinical application. We analyzed three gravity-dependent ASDs (ShuntAssistant [SA], Miethke; Gravity Compensating Accessory [GCA], Integra; SiphonX [SX], Sophysa), two membrane-controlled ASDs (Anti-Siphon Device [IASD], Integra; Delta Chamber [DC], Medtronic), and one flow-regulated ASD (SiphonGuard [SG], Codman). Defined pressure conditions within a simulated shunt system were generated (differential pressure 10-80 cmH2O), and the specific flow and pressure characteristics were measured. In addition, the gravity-dependent ASDs were measured in defined spatial positions (0-90°). The flow characteristics of the three gravity-assisted ASDs were largely dependent upon differential pressure and on their spatial position. All three devices were able to reduce the siphoning effect, but each to a different extent (flow at inflow pressure: 10 cmH2O, siphoning -20 cmH2O at 0°/90°: SA, 7.1 ± 1.2*/2.3 ±  0.5* ml/min; GCA, 10.5 ± 0.8/3.4 ± 0.4* ml/min; SX, 9.5 ± 1.2*/4.7 ± 1.9* ml/min, compared to control, 11.1 ± 0.4 ml/min [*p < 0.05]). The flow characteristics of the remaining ASDs were primarily dependent upon the inflow pressure effect (flow at 10 cmH2O, siphoning 0 cmH2O/ siphoning -20cmH2O: DC, 2.6 ± 0.1/ 4 ± 0.3* ml/min; IASD, 2.5 ± 0.2/ 0.8 ± 0.4* ml/min; SG, 0.8 ± 0.2*/ 0.2 ± 0.1* ml/min [*p < 0.05 vs. control, respectively]). The tested ASDs were able to control the siphoning effect within a simulated shunt system to differing degrees. Future comparative trials are needed to determine the type of device that is superior for clinical application.

  9. Transcriptome-Wide Identification of Differentially Expressed Genes in Solanum lycopersicon L. in Response to an Alfalfa-Protein Hydrolysate Using Microarrays.

    PubMed

    Ertani, Andrea; Schiavon, Michela; Nardi, Serenella

    2017-01-01

    An alfalfa -based protein hydrolysate (EM) has been tested in tomato ( Solanum lycopersicon L.) plants at two different concentrations (0.1 and 1 mL L -1 ) to get insight on its efficacy as biostimulant in this species and to unravel possible metabolic targets and molecular mechanisms that may shed light on its mode of action. EM was efficient in promoting the fresh biomass and content in chlorophyll and soluble sugars of tomato plants, especially when it was applied at the concentration of 1 mL L -1 . This effect on plant productivity was likely related to the EM-dependent up-regulation of genes identified via microarray and involved in primary carbon and nitrogen metabolism, photosynthesis, nutrient uptake and developmental processes. EM also up-regulated a number of genes implied in the secondary metabolism that leads to the synthesis of compounds (phenols and terpenes) functioning in plant development and interaction with the environment. Concomitantly, phenol content was enhanced in EM-treated plants. Several new genes have been identified in tomato as potential targets of EM action, like those involved in detoxification processes from reactive oxygen species and xenobiotic (particularly glutathione/ascorbate cycle-related and ABC transporters), and defense against abiotic and biotic stress. The model hypothesized is that elicitors present in the EM formulation like auxins, phenolics, and amino acids, may trigger a signal transduction pathway via modulation of the intracellular levels of the hormones ethylene, jasmonic acid and abscissic acid, which then further prompt the activation of a cascade events requiring the presence and activity of many kinases and transcription factors to activate stress-related genes. The genes identified suggest these kinases and transcription factors as players involved in a complex crosstalk between biotic and abiotic stress signaling pathways. We conclude that EM acts as a biostimulant in tomato due to its capacity to stimulate plant productivity and up-regulate stress-related responses. Its use in agricultural practices may reduce the need of inorganic fertilizers and pesticides, thereby reducing the environmental impact of productive agriculture.

  10. Transcriptome-Wide Identification of Differentially Expressed Genes in Solanum lycopersicon L. in Response to an Alfalfa-Protein Hydrolysate Using Microarrays

    PubMed Central

    Ertani, Andrea; Schiavon, Michela; Nardi, Serenella

    2017-01-01

    An alfalfa-based protein hydrolysate (EM) has been tested in tomato (Solanum lycopersicon L.) plants at two different concentrations (0.1 and 1 mL L-1) to get insight on its efficacy as biostimulant in this species and to unravel possible metabolic targets and molecular mechanisms that may shed light on its mode of action. EM was efficient in promoting the fresh biomass and content in chlorophyll and soluble sugars of tomato plants, especially when it was applied at the concentration of 1 mL L-1. This effect on plant productivity was likely related to the EM-dependent up-regulation of genes identified via microarray and involved in primary carbon and nitrogen metabolism, photosynthesis, nutrient uptake and developmental processes. EM also up-regulated a number of genes implied in the secondary metabolism that leads to the synthesis of compounds (phenols and terpenes) functioning in plant development and interaction with the environment. Concomitantly, phenol content was enhanced in EM-treated plants. Several new genes have been identified in tomato as potential targets of EM action, like those involved in detoxification processes from reactive oxygen species and xenobiotic (particularly glutathione/ascorbate cycle-related and ABC transporters), and defense against abiotic and biotic stress. The model hypothesized is that elicitors present in the EM formulation like auxins, phenolics, and amino acids, may trigger a signal transduction pathway via modulation of the intracellular levels of the hormones ethylene, jasmonic acid and abscissic acid, which then further prompt the activation of a cascade events requiring the presence and activity of many kinases and transcription factors to activate stress-related genes. The genes identified suggest these kinases and transcription factors as players involved in a complex crosstalk between biotic and abiotic stress signaling pathways. We conclude that EM acts as a biostimulant in tomato due to its capacity to stimulate plant productivity and up-regulate stress-related responses. Its use in agricultural practices may reduce the need of inorganic fertilizers and pesticides, thereby reducing the environmental impact of productive agriculture. PMID:28725232

  11. In vitro and in vivo investigations on the antitumour activity of Chelidonium majus.

    PubMed

    Capistrano I, Rica; Wouters, An; Lardon, Filip; Gravekamp, Claudia; Apers, Sandra; Pieters, Luc

    2015-12-15

    Chelidonium majus L. (Papaveraceae) (greater celandine) is a medicinal herb that is widely spread in Europe. Antitumoural activity has been reported for C. majus extracts. To investigate the antitumour activity of a C. majus extract in vitro and in vivo. Cytotoxic effects of C. majus extracts were evaluated on human cancer cell lines, i.e. PANC-1 (pancreas cancer), HT-29 (colon cancer), MDA-MB-231 (breast cancer), PC-EM005 and PC-EM002 (primary endometrium cancer cells), and PANC02 (murine pancreatic adenocarcinoma cells). A preliminary in vivo study was performed to evaluate the effect of a defatted C. majus extract and Ukrain(TM) in a highly metastatic murine pancreatic model. Chelidonium majus L. herb containing 1.26% (dry weight) of total alkaloids expressed as chelidonine was used to prepare an 80% ethanolic extract (CM2). This crude extract was then defatted with n-hexane, resulting in a defatted C. majus extract (CM2B). Cytotoxic effects of the two extracts (CM2 and CM2B) were evaluated on human and murine cell lines in vitro. CM2B and Ukrain(TM) were evaluated in a highly metastatic murine pancreatic model. Four main benzylisoquinoline alkaloids were identified in CM2B, i.e. chelidonine, sanguinarine, chelerythrine and protopine, using HPLC-UV. CM2 showed a high cytotoxic activity against PANC-1 (IC50, 20.7 µg/ml) and HT-29 (IC50, 20.6 µg/ml), and a moderate cytotoxic activity against MDA-MB-231 (IC50, 73.9 µg/ml). CM2 as well as CM2B showed a moderate to high cytotoxic activity against the PANC02 cell line (IC50, 34.4 and 36.0 µg/ml). Low to almost no cytotoxic effect was observed on primary endometrium cancer cells PC-EM005, PC-EM002 and on normal fibroblast cells 3T3, when treated with CM2B. Significantly less metastases were counted in mice treated with 1.2 mg/kg CM2B, but not with 3.6 mg/kg Ukrain(TM), compared to the control group. The extract, however, did not affect the weight of the primary tumours. Copyright © 2015 Elsevier GmbH. All rights reserved.

  12. [Salivary flow and psychoactive drug consumption in elderly people].

    PubMed

    Cabrera, Marcos Aparecido Sarria; Mesas, Arthur Eumann; Rossato, Luiz Angelo; Andrade, Selma Maffei de

    2007-01-01

    To analyze the association between low saliva flow rates and the use of psychoactive drugs among the elderly. A cross-sectional study was carried out with 267 elderly people from 60 to 74 years of age who lived in a borough of the city of Londrina, Paraná State, Brazil. Individuals with high functional dependence or restricted to bed were excluded. Saliva flow rate was the dependent variable with values under the first tercile being considered as low flow rates (less than 0.44 ml/min). The continuous use of psychoactive drugs (antidepressant, antiepileptic, sedative, antipsychotic, hypnotic or sedative-hypnotic drugs) was the independent variable. Multivariate analysis was performed taking into account gender, age and smoking status. The majority of the elderly were women (80.5%), with a mean age of 66.5 years. Use of psychoactive drugs was observed among 31 elderly (11.6%). Mean saliva flow rate was 0.76 ml/min, lower among users of psychoactive drugs (0.67 ml/min). In the multivariate analysis, use of psychoactive drugs was associated with low saliva flow rates (<0.44 ml/min), independent of gender, age or smoking. Results show that there is an association between use of psychoactive drugs and low saliva flow rates in this group of independent and non-institutionalized elderly. These conclusions stress the need of a rational use of these drugs, particularly among the elderly.

  13. ECOLOGICAL DETERMINANTS OF POPULATION STRUCTURE AND GENE FLOW BETWEEN SYMPATRIC FUNGAL SPECIES IN THE GENUS COLLEOTRICHUM FROM DIVERSE GRASS COMMUNITIES

    EPA Science Inventory

    This comparative analysis will allow us to detect historical events of interest such as population fragmentations, range expansions, and colonization in the Colletotrichum species that inhabit pooid grasses. What is learned from C. cereale populations in agro...

  14. Dialysate Flow Rate and Delivered Kt/Vurea for Dialyzers with Enhanced Dialysate Flow Distribution

    PubMed Central

    Idoux, John W.; Hamdan, Hiba; Ouseph, Rosemary; Depner, Thomas A.; Golper, Thomas A.

    2011-01-01

    Summary Background and objectives Previous in vitro and clinical studies showed that the urea mass transfer-area coefficient (KoA) increased with increasing dialysate flow rate. This observation led to increased dialysate flow rates in an attempt to maximize the delivered dose of dialysis (Kt/Vurea). Recently, we showed that urea KoA was independent of dialysate flow rate in the range 500 to 800 ml/min for dialyzers incorporating features to enhance dialysate flow distribution, suggesting that increasing the dialysate flow rate with such dialyzers would not significantly increase delivered Kt/Vurea. Design, setting, participants, & measurements We performed a multi-center randomized clinical trial to compare delivered Kt/Vurea at dialysate flow rates of 600 and 800 ml/min in 42 patients. All other aspects of the dialysis prescription, including treatment time, blood flow rate, and dialyzer, were kept constant for a given patient. Delivered single-pool and equilibrated Kt/Vurea were calculated from pre- and postdialysis plasma urea concentrations, and ionic Kt/V was determined from serial measurements of ionic dialysance made throughout each treatment. Results Delivered Kt/Vurea differed between centers; however, the difference in Kt/Vurea between dialysate flow rates of 800 and 600 ml/min was NS by any measure (95% confidence intervals of −0.064 to 0.024 for single-pool Kt/Vurea, −0.051 to 0.023 for equilibrated Kt/Vurea, and −0.029 to 0.099 for ionic Kt/V). Conclusions These data suggest that increasing the dialysate flow rate beyond 600 ml/min for these dialyzers offers no benefit in terms of delivered Kt/Vurea. PMID:21799145

  15. Radiocarbon dates for lava flows from northeast rift zone of Mauna Loa Volcano, Hilo 7 1/2 minute quadrangle, Island of Hawaii

    USGS Publications Warehouse

    Buchanan-Banks, J. M.; Lockwood, J.P.; Rubin, M.

    1989-01-01

    Twenty-eight 14C analyses are reported for carbonized roots and other plant material collected from beneath 15 prehistoric lava flows erupted from the northeast rift zone (NERZ) of Mauna Loa Volcano (ML). The new 14C dates establish ages for 13 previously undated lava flows, and correct or add to information previously reported. Limiting ages on other flows that lie either above or below the dated flows are also established. These dates help to unravel the eruptive history of ML's NERZ. -from Authors

  16. Ventricular distension and diastolic coronary blood flow in the anaesthetized dog.

    PubMed

    Gattullo, D; Linden, R J; Losano, G; Pagliaro, P; Westerhof, N

    1993-01-01

    There appears to be no agreement as to whether or not an increase in diastolic left ventricular pressure and/or volume can cause a decrease in diastolic coronary blood flow. We investigated the problem in the anaesthetized dog using a flaccid freely distensible latex balloon inserted into the left ventricle with the animal on extracorporeal circulation and the coronary perfusion pressure constant at about 45 mm Hg. Maximal vasodilatation and suppression of autoregulation in coronary vasculature was obtained by the intracoronary infusion of dipyridamole (10-40 mg/h). Ventricular volume was changed in steps of 10 ml from 10 to 70 ml and back to 10 ml, whilst recording coronary blood flow and left ventricular pressure in the left circumflex coronary artery. Over a range of ventricular volumes from 20 to 50 ml and a concomitant rise in diastolic ventricular pressure to about 20 mm Hg there was no change in the diastolic coronary flow. Only when the ventricular volume was more than two times the control value (i.e. exceeded 50 ml) and left ventricular pressure was more than 20 mm Hg, was there a decrease in coronary flow. During the return of the volume to the control level there was a fall in diastolic flow and ventricular contractility with respect to the values obtained when the volume was increased; these two effects were transient lasting less than 10 min. It was not considered that any of the three models of the coronary circulation, waterfall, intramyocardial pump or varying elastance model could explain our results.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Enzymatically Modified Starch Favorably Modulated Intestinal Transit Time and Hindgut Fermentation in Growing Pigs

    PubMed Central

    Newman, M. A.; Zebeli, Q.; Velde, K.; Grüll, D.; Molnar, T.; Kandler, W.; Metzler-Zebeli, B. U.

    2016-01-01

    Aside from being used as stabilizing agents in many processed foods, chemically modified starches may act as functional dietary ingredients. Therefore, development of chemically modified starches that are less digestible in the upper intestinal segments and promote fermentation in the hindgut receives considerable attention. This study aimed to investigate the impact of an enzymatically modified starch (EMS) on nutrient flow, passage rate, and bacterial activity at ileal and post-ileal level. Eight ileal-cannulated growing pigs were fed 2 diets containing 72% purified starch (EMS or waxy cornstarch as control) in a cross-over design for 10 d, followed by a 4-d collection of feces and 2-d collection of ileal digesta. On d 17, solid and liquid phase markers were added to the diet to determine ileal digesta flow for 8 h after feeding. Reduced small intestinal digestion after the consumption of the EMS diet was indicated by a 10%-increase in ileal flow and fecal excretion of dry matter and energy compared to the control diet (P<0.05). Moreover, EMS feeding reduced ileal transit time of both liquid and solid fractions compared to the control diet (P<0.05). The greater substrate flow to the large intestine with the EMS diet increased the concentrations of total and individual short-chain fatty acids (SCFA) in feces (P<0.05). Total bacterial 16S rRNA gene abundance was not affected by diet, whereas the relative abundance of the Lactobacillus group decreased (P<0.01) by 50% and of Enterobacteriaceae tended (P<0.1) to increase by 20% in ileal digesta with the EMS diet compared to the control diet. In conclusion, EMS appears to resemble a slowly digestible starch by reducing intestinal transit and increasing SCFA in the distal large intestine. PMID:27936165

  18. Dialyzer clearances and mass transfer-area coefficients for small solutes at low dialysate flow rates.

    PubMed

    Leypoldt, John K; Kamerath, Craig D; Gilson, Janice F; Friederichs, Goetz

    2006-01-01

    New daily hemodialysis therapies operate at low dialysate flow rates to minimize dialysate volume requirements; however, the dependence of dialyzer clearances and mass transfer-area coefficients for small solutes on dialysate flow rate under these conditions have not been studied extensively. We evaluated in vitro dialyzer clearances for urea and creatinine at dialysate flow rates of 40, 80, 120, 160, and 200 ml/min and ultrafiltration flow rates of 0, 1, and 2 l/h, using a dialyzer containing PUREMA membranes (NxStage Medical, Lawrence, MA). Clearances were measured directly across the dialyzer by perfusing bovine blood with added urea and creatinine single pass through the dialyzer at a nominal blood flow rate of 400 ml/min. Limited, additional studies were performed with the use of dialyzers containing PUREMA membranes at a blood flow rate of 200 ml/min and also with the use of other dialyzers containing polysulfone membranes (Optiflux 160NR, FMC-NA, Ogden, UT) and dialyzers containing Synphan membranes (NxStage Medical). For dialyzers containing PUREMA membranes, urea and creatinine clearances increased (p < 0.001) with increasing dialysate and ultrafiltration flow rates but were not different at blood flow rates of 200 and 400 ml/min. Dialysate saturation, defined as dialysate outlet concentration divided by blood water inlet concentration, for urea and creatinine was independent of blood and ultrafiltration flow rate but varied inversely (p < 0.001) with dialysate flow rate. Mass transfer-area coefficients for urea and creatinine were independent of blood and ultrafiltration flow rate but decreased (p < 0.001) with decreasing dialysate flow rate. Calculated mass transfer-area coefficients at low dialysate flow rates for all dialyzers tested were substantially lower than those reported by the manufacturers under conventional conditions. We conclude that dialyzers require specific characterization under relevant conditions if they are used in novel daily hemodialysis therapies at low dialysate flow rate.

  19. What infusion flow should be used for mid-dilution hemodiafiltration?

    PubMed

    Maduell, Francisco; Arias, Marta; Fontseré, Néstor; Vera, Manel; Masso, Elisabeth; Garro, Julia; Barros, Xoana; Martina, Maria N; Elena, Montserrat; Bergadá, Eduardo; Cases, Aleix; Bedini, Jose Luis; Campistol, Josep M

    2010-01-01

    There is still no consensus on the optimal infusion flow (Qi) in mid-dilution hemodiafiltration. The aim of this study was to compare mid-dilution with varying Qi. Prospective study in 25 patients who underwent seven hemodialysis sessions with a Qi of 0, 50, 100, 150, 200, 250 and 300 ml/min. All sessions were well tolerated except Qi 300 ml/min. No significant differences in urea, creatinine, alpha(1)-microglobulin or alpha(1)-acid glycoprotein reduction ratios were observed. beta(2)-Microglobulin, myoglobin and prolactin reduction ratios were higher with Qi 150, 200, 250 and 300 ml/min in comparison with Qi of 0, 50 and 100 ml/min. There were no differences in the removal of small or larger molecules when Qi was 150 ml/min or higher. Optimal Qi in mid-dilution appears to be in the range of 150-250 ml/min since good clinical outcomes, similar efficiency and no technical complications up to a Qi of 250 ml/min were observed.

  20. The Role of New Removable Complete Dentures in Stimulated Salivary Flow and Taste Perception.

    PubMed

    Tango, Rubens Nisie; Arata, Anelyse; Borges, Alexandre Luiz Souto; Costa, Anna K F; Pereira, Luciano Jose; Kaminagakura, Estela

    2018-04-01

    To evaluate the effect of replacement of inadequate complete dentures on salivary flow and taste perception in geriatric patients. Thirty-three patients, 13 males and 20 females, with a mean age of 64.4 years were submitted to stimulated and unstimulated salivary flow rate and salivary pH measurements, and sense of taste evaluation. Tests were performed 3 months before complete denture substitution and 3 weeks after denture insertion. The mean for unstimulated saliva (USS) was 2.1 ml before and 2.7 ml after replacement (p = 0.003). The mean volume of stimulated saliva was 6.3 ml before and 8.2 ml after replacement (p = 0.004). The pH mean of USS was 7.8 ± 0.44 before and 8.02 ± 0.41 after replacement (p = 0.005). No statistically significant difference was determined in the sense of taste before and 3 weeks after complete denture replacement. The replacement of inadequate complete dentures increases saliva flow; however, it does not improve taste perception. © 2016 by the American College of Prosthodontists.

  1. Effect of cell physicochemical characteristics and motility on bacterial transport in groundwater

    USGS Publications Warehouse

    Becker, M.W.; Collins, S.A.; Metge, D.W.; Harvey, R.W.; Shapiro, A.M.

    2004-01-01

    The influence of physicochemical characteristics and motility on bacterial transport in groundwater were examined in flow-through columns. Four strains of bacteria isolated from a crystalline rock groundwater system were investigated, with carboxylate-modified and amidine-modified latex microspheres and bromide as reference tracers. The bacterial isolates included a gram-positive rod (ML1), a gram-negative motile rod (ML2), a nonmotile mutant of ML2 (ML2m), and a gram-positive coccoid (ML3). Experiments were repeated at two flow velocities, in a glass column packed with glass beads, and in another packed with iron-oxyhydroxide coated glass beads. Bacteria breakthrough curves were interpreted using a transport equation that incorporates a sorption model from microscopic observation of bacterial deposition in flow-cell experiments. The model predicts that bacterial desorption rate will decrease exponentially with the amount of time the cell is attached to the solid surface. Desorption kinetics appeared to influence transport at the lower flow rate, but were not discernable at the higher flow rate. Iron-oxyhydroxide coatings had a lower-than-expected effect on bacterial breakthrough and no effect on the microsphere recovery in the column experiments. Cell wall type and shape also had minor effects on breakthrough. Motility tended to increase the adsorption rate, and decrease the desorption rate. The transport model predicts that at field scale, desorption rate kinetics may be important to the prediction of bacteria transport rates. ?? 2003 Elsevier B.V. All rights reserved.

  2. Intensive insulin treatment improves forearm blood flow in critically ill patients: a randomized parallel design clinical trial.

    PubMed

    Žuran, Ivan; Poredos, Pavel; Skale, Rafael; Voga, Gorazd; Gabrscek, Lucija; Pareznik, Roman

    2009-01-01

    Intensive insulin treatment of critically ill patients was seen as a promising method of treatment, though recent studies showed that reducing the blood glucose level below 6 mmol/l had a detrimental outcome. The mechanisms of the effects of insulin in the critically ill are not completely understood. The purpose of the study was to test the hypothesis that intensive insulin treatment may influence forearm blood flow independently of global hemodynamic indicators. The study encompassed 29 patients of both sexes who were admitted to the intensive care unit due to sepsis and required artificial ventilation as the result of acute respiratory failure. 14 patients were randomly selected for intensive insulin treatment (Group 1; blood glucose concentration 4.4-6.1 mmol/l), and 15 were selected for conventional insulin treatment (Group 2; blood glucose level 7.0 mmol/l-11.0 mmol/l). At the start of the study (t0, beginning up to 48 hours after admittance and the commencement of artificial ventilation), at 2 hours (t1), 24 hours (t2), and 72 hours (t3) flow in the forearm was measured for 60 minutes using the strain-gauge plethysmography method. Student's t-test of independent samples was used for comparisons between the two groups, and Mann-Whitney's U-test where appropriate. Linear regression analysis and the Pearson correlation coefficient were used to determine the levels of correlation. The difference in 60-minute forearm flow at the start of the study (t0) was not statistically significant between groups, while at t2 and t3 significantly higher values were recorded in Group 1 (t2; Group 1: 420.6 +/- 188.8 ml/100 ml tissue; Group 2: 266.1 +/- 122.2 ml/100 ml tissue (95% CI 30.9-278.0, P = 0.02); t3; Group 1: 369.9 +/- 150.3 ml/100 ml tissue; Group 2: 272.6 +/- 85.7 ml/100 ml tissue (95% CI 5.4-190.0, P = 0.04). At t1 a trend towards significantly higher values in Group 1 was noted (P = 0.05). The level of forearm flow was related to the amount of insulin infusion (r = 0.40). Compared to standard treatment, intensive insulin treatment of critically ill patients increases forearm flow. Flow increase was weakly related to the insulin dose, though not to blood glucose concentration. ISRCTN39026810.

  3. Intensive insulin treatment improves forearm blood flow in critically ill patients: a randomized parallel design clinical trial

    PubMed Central

    2009-01-01

    Introduction Intensive insulin treatment of critically ill patients was seen as a promising method of treatment, though recent studies showed that reducing the blood glucose level below 6 mmol/l had a detrimental outcome. The mechanisms of the effects of insulin in the critically ill are not completely understood. The purpose of the study was to test the hypothesis that intensive insulin treatment may influence forearm blood flow independently of global hemodynamic indicators. Methods The study encompassed 29 patients of both sexes who were admitted to the intensive care unit due to sepsis and required artificial ventilation as the result of acute respiratory failure. 14 patients were randomly selected for intensive insulin treatment (Group 1; blood glucose concentration 4.4-6.1 mmol/l), and 15 were selected for conventional insulin treatment (Group 2; blood glucose level 7.0 mmol/l-11.0 mmol/l). At the start of the study (t0, beginning up to 48 hours after admittance and the commencement of artificial ventilation), at 2 hours (t1), 24 hours (t2), and 72 hours (t3) flow in the forearm was measured for 60 minutes using the strain-gauge plethysmography method. Student's t-test of independent samples was used for comparisons between the two groups, and Mann-Whitney's U-test where appropriate. Linear regression analysis and the Pearson correlation coefficient were used to determine the levels of correlation. Results The difference in 60-minute forearm flow at the start of the study (t0) was not statistically significant between groups, while at t2 and t3 significantly higher values were recorded in Group 1 (t2; Group 1: 420.6 ± 188.8 ml/100 ml tissue; Group 2: 266.1 ± 122.2 ml/100 ml tissue (95% CI 30.9-278.0, P = 0.02); t3; Group 1: 369.9 ± 150.3 ml/100 ml tissue; Group 2: 272.6 ± 85.7 ml/100 ml tissue (95% CI 5.4-190.0, P = 0.04). At t1 a trend towards significantly higher values in Group 1 was noted (P = 0.05). The level of forearm flow was related to the amount of insulin infusion (r = 0.40). Conclusions Compared to standard treatment, intensive insulin treatment of critically ill patients increases forearm flow. Flow increase was weakly related to the insulin dose, though not to blood glucose concentration. Trial Registration Trial number: ISRCTN39026810. PMID:20003200

  4. Does Arterial Spin-labeling MR Imaging–measured Tumor Perfusion Correlate with Renal Cell Cancer Response to Antiangiogenic Therapy in a Mouse Model?

    PubMed Central

    Schor-Bardach, Rachel; Alsop, David C.; Pedrosa, Ivan; Solazzo, Stephanie A.; Wang, Xiaoen; Marquis, Robert P.; Atkins, Michael B.; Regan, Meredith; Signoretti, Sabina; Lenkinski, Robert E.; Goldberg, S. Nahum

    2009-01-01

    Purpose: To determine whether arterial spin-labeling (ASL) magnetic resonance (MR) imaging findings at baseline and early during antiangiogenic therapy can predict later resistance to therapy. Materials and Methods: Protocol was approved by an institutional animal care and use committee. Caki-1, A498, and 786-0 human renal cell carcinoma (RCC) xenografts were implanted in 39 nude mice. Animals received 80 mg sorafenib per kilogram of body weight once daily once tumors measured 12 mm. ASL imaging was performed at baseline and day 14, with additional imaging performed for 786-0 and A498 (3 days to 12 weeks). Mean blood flow values and qualitative differences in spatial distribution of blood flow were analyzed and compared with histopathologic findings for viability and microvascular density. t Tests were used to compare differences in mean tumor blood flow. Bonferroni-adjusted P values less than .05 denoted significant differences. Results: Baseline blood flow was 80.1 mL/100 g/min ± 23.3 (standard deviation) for A498, 75.1 mL/100 g/min ± 28.6 for 786-0, and 10.2 mL/100 g/min ± 9.0 for Caki-1. Treated Caki-1 showed no significant change (14.9 mL/100 g/min ± 7.6) in flow, whereas flow decreased in all treated A498 on day 14 (47.9 mL/100 g/min ± 21.1) and in 786-0 on day 3 (20.3 mL/100 g/min ± 8.7) (P = .003 and .03, respectively). For A498, lowest values were measured at 28–42 days of receiving sorafenib. Regions of increased flow occurred on days 35–49, 17–32 days before documented tumor growth and before significant increases in mean flow (day 77). Although 786-0 showed new, progressive regions with signal intensity detected as early as day 5 that correlated to viable tumor at histopathologic examination, no significant changes in mean flow were noted when day 3 was compared with all subsequent days (P > .99). Conclusion: ASL imaging provides clinically relevant information regarding tumor viability in RCC lines that respond to sorafenib. © RSNA, 2009 PMID:19474376

  5. Bacopa monnieri extract increases rat coronary flow and protects against myocardial ischemia/reperfusion injury.

    PubMed

    Srimachai, Sirintorn; Devaux, Sylvie; Demougeot, Celine; Kumphune, Sarawut; Ullrich, Nina D; Niggli, Ernst; Ingkaninan, Kornkanok; Kamkaew, Natakorn; Scholfield, C Norman; Tapechum, Sompol; Chootip, Krongkarn

    2017-02-20

    This study explored Bacopa monnieri, a medicinal Ayurvedic herb, as a cardioprotectant against ischemia/reperfusion injury using cardiac function and coronary flow as end-points. In normal isolated rat hearts, coronary flow, left ventricular developed pressure, heart rate, and functional recovery were measured using the Langendorff preparation. Hearts were perfused with either (i) Krebs-Henseleit (normal) solution, (control), or with 30, 100 μg/ml B. monnieri ethanolic extract (30 min), or (ii) with normal solution or extract for 10 min preceding no-perfusion ischemia (30 min) followed by reperfusion (30 min) with normal solution. Infarct volumes were measured by triphenyltetrazolium staining. L-type Ca 2+ -currents (I Ca, L ) were measured by whole-cell patching in HL-1 cells, a mouse atrial cardiomyocyte cell line. Cytotoxicity of B. monnieri was assessed in rat isolated ventricular myocytes by trypan blue exclusion. In normally perfused hearts, B. monnieri increased coronary flow by 63 ± 13% (30 μg/ml) and 216 ± 21% (100 μg/ml), compared to control (5 ± 3%) (n = 8-10, p < 0.001). B. monnieri treatment preceding ischemia/reperfusion improved left ventricular developed pressure by 84 ± 10% (30 μg/ml), 82 ± 10% (100 μg/ml) and 52 ± 6% (control) compared to pre- ischemia/reperfusion. Similarly, functional recovery showed a sustained increase. Moreover, B. monnieri (100 μg/ml) reduced the percentage of infarct size from 51 ± 2% (control) to 25 ± 2% (n = 6-8, p < 0.0001). B. monnieri (100 μg/ml) reduced I Ca, L by 63 ± 4% in HL-1 cells. Ventricular myocyte survival decreased at higher concentrations (50-1000 μg/ml) B. monnieri. B. monnieri improves myocardial function following ischemia/reperfusion injury through recovery of coronary blood flow, contractile force and decrease in infarct size. Thus this may lead to a novel cardioprotectant strategy.

  6. Visceral perfusion abnormalities following complement activation. Clues to the mediators of organ ischemia in trauma and sepsis. First place winner: Conrad Jobst Award.

    PubMed

    Schirmer, W J; Schirmer, J M; Naff, G B; Fry, D E

    1988-12-01

    Complement, activated during infection and injury, has been implicated as a mediator of microvascular injury and obstruction. This study examines how two potent activators of complement, zymosan, and cobra venom factor (CVF), affect systemic and visceral perfusion. Rats were injected with either saline (1 ml/kg), zymosan (5 mg/kg) or CVF (5 units/kg) at t = 0 and 30 minutes. Thermodilution cardiac output, mean arterial pressure, heart rate, systemic vascular resistance, and hematocrit were determined at t = 2 hours. Effective hepatic and renal blood flows, by clearance of galactose and p-aminohippurate respectively, were determined over the next hour. The per cent change in total hemolytic complement from t = 0 to t = 3 hours was determined by immune hemolysis of sheep erythrocytes. There was no difference in systemic hemodynamic parameters between the three groups. Hepatic blood flow was depressed in both the zymosan (3.83 +/- 0.23 ml/min/100 g) and CVF (3.72 +/- 0.20 ml/min/100 g) groups compared with controls (4.62 +/- 0.19 ml/min/100 g, P less than 0.05). Renal blood flow in the zymosan-treated group (6.40 +/- 0.24 ml/min/100 g) increased over control (4.80 +/- 0.40 ml/min/100 g, P less than 0.05) but was unchanged in the CVF group (5.06 +/- 0.23 ml/min/100 g). The amount of complement activated correlated with the change in hepatic (r = -0.419, P less than 0.05) but not renal (r = -0.008, P = 0.917) flow. Complement activation may occupy a proximal position in the pathogenesis of hepatic ischemia associated with trauma and sepsis.

  7. Design and implementation of CUAHSI WaterML and WaterOneFlow Web Services

    NASA Astrophysics Data System (ADS)

    Valentine, D. W.; Zaslavsky, I.; Whitenack, T.; Maidment, D.

    2007-12-01

    WaterOneFlow is a term for a group of web services created by and for the Consortium of Universities for the Advancement of Hydrologic Science, Inc. (CUAHSI) community. CUAHSI web services facilitate the retrieval of hydrologic observations information from online data sources using the SOAP protocol. CUAHSI Water Markup Language (below referred to as WaterML) is an XML schema defining the format of messages returned by the WaterOneFlow web services. \

  8. Effect of age on cerebral blood flow during hypothermic cardiopulmonary bypass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brusino, F.G.; Reves, J.G.; Smith, L.R.

    1989-04-01

    Cerebral blood flow was measured in 20 patients by xenon 133 clearance methodology during nonpulsatile hypothermic cardiopulmonary bypass to determine the effect of age on regional cerebral blood flow during these conditions. Measurements of cerebral blood flow at varying perfusion pressures were made in patients arbitrarily divided into two age groups at nearly identical nasopharyngeal temperature, hematocrit value, and carbon dioxide tension and with equal cardiopulmonary bypass flows of 1.6 L/min/m2. The range of mean arterial pressure was 30 to 110 mm Hg for group I (less than or equal to 50 years of age) and 20 to 90 mmmore » Hg for group II (greater than or equal to 65 years of age). There was no significant difference (p = 0.32) between the mean arterial pressure in group I (54 +/- 28 mm Hg) and that in group II (43 +/- 21 mm Hg). The range of cerebral blood flow was 14.8 to 29.2 ml/100 gm/min for group I and 13.8 to 37.5 ml/100 gm/min for group II. There was no significant difference (p = 0.37) between the mean cerebral blood flow in group I (21.5 +/- 4.6 ml/100 gm/min) and group II (24.3 +/- 8.1 ml/100 gm/min). There was a poor correlation between mean arterial pressure and cerebral blood flow in both groups: group I, r = 0.16 (p = 0.67); group II, r = 0.5 (p = 0.12). In 12 patients, a second cerebral blood flow measurements was taken to determine the effect of mean arterial pressure on cerebral blood flow in the individual patient. Changes in mean arterial pressure did not correlate with changes in cerebral blood flow (p less than 0.90). We conclude that age does not alter cerebral blood flow and that cerebral blood flow autoregulation is preserved in elderly patients during nonpulsatile hypothermic cardiopulmonary bypass.« less

  9. Indomethacin is a Placental Vasodilator in the Dog

    PubMed Central

    Gerber, John G.; Branch, Robert A.; Hubbard, Walter C.; Nies, Alan S.

    1978-01-01

    The effect of 8 mg/kg of indomethacin on uterine blood flow, prostaglandin production, and intraamniotic fluid pressure was examined in late pregnant dogs. Uterine blood flow was measured with 15 μm radiolabeled microspheres. Because we found that a significant percentage of the microspheres shunted through the placental circulation into the lungs, we calculated placental blood flow by adding the shunted microspheres through the placenta to the nonshunted microspheres in the placenta. Total uterine blood flow significantly increased from 271±69 ml/min during control period to 371±72 ml/min (P < 0.01) 30 min after indomethacin. This increase was attributable to the change in blood flow to the placental circulation (222±58 to 325±63 ml/min; P < 0.01). Associated with these hemodynamic changes we found an almost complete suppression of uterine prostaglandin E2 production (1,654±305 to 51±25 pg/ml; P < 0.01) as measured by gas chromatography-mass spectrometry. In addition, we found that indomethacin treatment resulted in uterine relaxation as measured by intraamniotic fluid pressure changes (11.2±1.3 mm Hg to 8.5±1.2 mm Hg; P < 0.001). We conclude that indomethacin causes an increase in placental blood flow without any change in flow to the rest of the uterus, and that this dose of the drug inhibits greater than 95% of uterine prostaglandin production. In addition, indomethacin is responsible for uterine relaxation. The increase in placental blood flow after indomethacin is probably a result of uterine relaxation, which is secondary to prostaglandin synthesis inhibition. PMID:659627

  10. The effect of changing the contact surface area between pleural liquid and pleura on the turnover of pleural liquid.

    PubMed

    Nakamura, T; Hara, H; Ijima, F; Arai, T; Kira, S

    1984-03-01

    To study the dynamics of pleural liquid, 250 ml of saline labeled with markers were injected into the pleural cavity of anesthetized dogs. For 3 h, liquid volume and concentration of these markers were measured. In a control group of dogs, the turnover rate of pleural liquid was 19.6 +/- 5.6 ml/min and lymphatic flow was 0.58 +/- 0.07 ml/min. In a group of pneumonectomized dogs, the turnover rate and lymphatic flow fell to about one fourth of those in the control group. When the left pulmonary artery was occluded, the turnover rate was halved, but lymphatic flow was not significantly different from that in the control group. These results suggest that the turnover rate of pleural liquid is dependent on the area of contact between pleural liquid and pleura and on the blood flow of the pleura. In addition, it appears that changes in pleural liquid volume are dependent on lymphatic flow.

  11. Electromembrane Surrounded Solid Phase Microextraction Followed by Injection Port Derivatization and Gas Chromatography-Flame Ionization Detector Analysis for Determination of Acidic Herbicides in Plant Tissue.

    PubMed

    Rezazadeh, Maryam; Yamini, Yadollah; Seidi, Shahram; Tahmasebi, Elham; Rezaei, Fatemeh

    2014-04-09

    Electromembrane surrounded solid phase microextraction (EM-SPME) of acidic herbicides was studied for the first time. In order to investigate the capability of this new microextraction technique to analyze acidic targets, chlorophenoxy acid (CPA) herbicides were quantified in plant tissue. 1-Octanol, was sustained in the pores of the wall of a hollow fiber and served as supported liquid membrane (SLM). Other EM-SPME related parameters, including extraction time, applied voltage, and pHs of the sample solution and the acceptor phase, were optimized using experimental design. A 20 min time frame was needed to reach the highest extraction efficiency of the analytes from a 24 mL alkaline sample solution across the organic liquid membrane and into the aqueous acceptor phase through a 50 V electrical field, and to their final adsorption on a carbonaceous anode. In addition to high sample cleanup, which made the proposed method appropriate for analysis of acidic compounds in a complicated media (plant tissue), 4.8% of 2-methyl-4-chlorophenoxyacetic acid (MCPA) and 0.6% of 2,4-dichlorophenoxyacetic acid (2,4-D) were adsorbed on the anode, resulting in suitable detection limits (less than 5 ng mL -1 ), and admissible repeatability and reproducibility (intra- and interassay precision were in the ranges of 5.2-8.5% and 8.8-12.0%, respectively). Linearity of the method was scrutinized within the ranges of 1.0-500.0 and 10.0-500.0 ng mL -1 for MCPA and 2,4-D, respectively, and coefficients of determination greater than 0.9958 were obtained. Optimal conditions of EM-SPME of the herbicides were employed for analysis of CPAs in whole wheat tissue.

  12. [Investigation of the clinical value of total salival flow rates].

    PubMed

    Wang, S; Zhao, Z; Li, J

    1998-11-01

    To investigate clinical value of total saliva flow rates. The symptom of dry mouth was correlated with unstimulated (UWSFR) and stimulated (SWSFR) whole saliva flow rates on chewing medical paraffin in 62 patients with dry mouth complaints (30 with Sjögren's syndrome, 32 with sialosis) and 23 controls. The symptom of dry mouth was classified into 0,1,2,3,4 according to a treatment emergent symptom scale (TESS). UWSFR and SWSFR were determined after fasting in the morning. UWSFR was (0.070 +/- 0.089) ml/min in Sjögren's syndrome, (0.175 +/- 0.115) ml/min in sialosis, (0.330 +/- 0.188) ml/min in controls. SWSFR was (0.709 +/- 0.720) ml/min in Sjögren's syndrome, (1.561 +/- 0.867) ml/min in sialosis, (1.894 +/- 0.661) ml/min in controls. A highly significant correlation was found between TESS score and UWSFR and between TESS score and SWSFR. Only UWSFR was decreased in the patients with a TESS score of 1 or 2, while both UWSFR and SWSFR were significantly decreased in patients with TESS scores of 3,4. It is concluded that UWSFR is more sensitive in relation to dry mouth complaints than SWSFR, and that a mild dry mouth is mainly related to decreased UWSFR.

  13. Buried structure for increasing fabrication performance of micromaterial by electromigration

    NASA Astrophysics Data System (ADS)

    Kimura, Yasuhiro; Saka, Masumi

    2016-06-01

    The electromigration (EM) technique is a physical synthetic growth method for micro/nanomaterials. EM causes atomic diffusion in a metal line by high-density electron flows. The intentional control of accumulation and relaxation of atoms by EM can lead to the fabrication of a micro/nanomaterial. TiN passivation has been utilized as a component of sample in the EM technique. Although TiN passivation can simplify the cumbersome processes for preparing the sample, the leakage of current naturally occurs because of the conductivity of TiN as a side effect and decreases the performance of micro/nanomaterial fabrication. In the present work, we propose a buried structure, which contributes to significantly decreasing the current for fabricating an Al micromaterial by confining the current flow in the EM technique. The fabrication performance was evaluated based on the threshold current for fabricating an Al micromaterial using the buried structure and the previous structure with the leakage of current.

  14. Measurement of total and unilateral renal blood flow by oblique-angle velocity-encoded 2D-cine magnetic resonance angiography.

    PubMed

    Lundin, B; Cooper, T G; Meyer, R A; Potchen, E J

    1993-01-01

    Two independent measurements of total renal blood flow (RBF) were made in healthy human subjects (n = 14, mean age 30 yr) by CINE phase-contrast magnetic resonance angiography. RBF, measured by summing the flows measured in the right and left renal arteries, was 1152 +/- 44 ml/min (mean +/- SE). RBF, measured from the difference between supra- and infrarenal abdominal aorta flow, was 1109 +/- 68 ml/min. Regression analysis of the comparison of these two different RBF calculations yielded a correlation coefficient of 0.72 at a p < .05 level of significance. Based on other studies of RBF in normal subjects by para-aminohippuric acid (PAH) clearance, the expected RBF in this subject group was 1211 +/- 62 ml/min. The results indicate that noninvasive measurement of RBF is possible using phase-contrast magnetic resonance methods.

  15. ART-ML - a novel XML format for the biological procedures modeling and the representation of blood flow simulation.

    PubMed

    Karvounis, E C; Tsakanikas, V D; Fotiou, E; Fotiadis, D I

    2010-01-01

    The paper proposes a novel Extensible Markup Language (XML) based format called ART-ML that aims at supporting the interoperability and the reuse of models of blood flow, mass transport and plaque formation, exported by ARTool. ARTool is a platform for the automatic processing of various image modalities of coronary and carotid arteries. The images and their content are fused to develop morphological models of the arteries in easy to handle 3D representations. The platform incorporates efficient algorithms which are able to perform blood flow simulation. In addition atherosclerotic plaque development is estimated taking into account morphological, flow and genetic factors. ART-ML provides a XML format that enables the representation and management of embedded models within the ARTool platform and the storage and interchange of well-defined information. This approach influences in the model creation, model exchange, model reuse and result evaluation.

  16. Assessing Effects of Oxidizer Characteristics on Composite Reaction Kinetics

    DTIC Science & Technology

    2013-12-01

    in its spark gap is ionized and creates conductive plasma allowing current flow to the EBW. The EBW is a type of detonator which utilizes shockwaves...flow rate of 70 mL min-1 for the remainder of the cycle. Sintering can occur during heating and melting, ultimately affecting heat transfer in the...argon at a flow rate of 70 mL min-1 for the remainder of the cycle. Sintering can occur during heating and melting, ultimately affecting heat transfer

  17. Application and performance of an ML-EM algorithm in NEXT

    NASA Astrophysics Data System (ADS)

    Simón, A.; Lerche, C.; Monrabal, F.; Gómez-Cadenas, J. J.; Álvarez, V.; Azevedo, C. D. R.; Benlloch-Rodríguez, J. M.; Borges, F. I. G. M.; Botas, A.; Cárcel, S.; Carrión, J. V.; Cebrián, S.; Conde, C. A. N.; Díaz, J.; Diesburg, M.; Escada, J.; Esteve, R.; Felkai, R.; Fernandes, L. M. P.; Ferrario, P.; Ferreira, A. L.; Freitas, E. D. C.; Goldschmidt, A.; González-Díaz, D.; Gutiérrez, R. M.; Hauptman, J.; Henriques, C. A. O.; Hernandez, A. I.; Hernando Morata, J. A.; Herrero, V.; Jones, B. J. P.; Labarga, L.; Laing, A.; Lebrun, P.; Liubarsky, I.; López-March, N.; Losada, M.; Martín-Albo, J.; Martínez-Lema, G.; Martínez, A.; McDonald, A. D.; Monteiro, C. M. B.; Mora, F. J.; Moutinho, L. M.; Muñoz Vidal, J.; Musti, M.; Nebot-Guinot, M.; Novella, P.; Nygren, D. R.; Palmeiro, B.; Para, A.; Pérez, J.; Querol, M.; Renner, J.; Ripoll, L.; Rodríguez, J.; Rogers, L.; Santos, F. P.; dos Santos, J. M. F.; Sofka, C.; Sorel, M.; Stiegler, T.; Toledo, J. F.; Torrent, J.; Tsamalaidze, Z.; Veloso, J. F. C. A.; Webb, R.; White, J. T.; Yahlali, N.

    2017-08-01

    The goal of the NEXT experiment is the observation of neutrinoless double beta decay in 136Xe using a gaseous xenon TPC with electroluminescent amplification and specialized photodetector arrays for calorimetry and tracking. The NEXT Collaboration is exploring a number of reconstruction algorithms to exploit the full potential of the detector. This paper describes one of them: the Maximum Likelihood Expectation Maximization (ML-EM) method, a generic iterative algorithm to find maximum-likelihood estimates of parameters that has been applied to solve many different types of complex inverse problems. In particular, we discuss a bi-dimensional version of the method in which the photosensor signals integrated over time are used to reconstruct a transverse projection of the event. First results show that, when applied to detector simulation data, the algorithm achieves nearly optimal energy resolution (better than 0.5% FWHM at the Q value of 136Xe) for events distributed over the full active volume of the TPC.

  18. Peripheral Vascular Resistance Impairment during Isometric Physical Exercise in Normotensive Offspring of Hypertensive Parents.

    PubMed

    Portela, Natália; Amaral, Josária Ferraz; Mira, Pedro Augusto de Carvalho; Souza, Livia Victorino de; Martinez, Daniel Godoy; Laterza, Mateus Camaroti

    2017-07-10

    A family history of hypertension is associated with vascular and autonomic abnormalities, as well as an impaired neurohemodynamic response to exercise. To test the hypothesis that normotensive individuals with a family history of hypertension present an impaired peripheral vascular resistance response to exercise. The study included 37 normotensive volunteers of both sexes who were sedentary, eutrophic, and nonsmokers, comprising 23 with (FH+; 24 ± 3 years) and 14 without (FH-; 27 ± 5 years) a family history of hypertension. Blood pressure, heart rate (DIXTAL®), forearm blood flow (Hokanson®), and peripheral vascular resistance were simultaneously measured for 3 minutes during rest and, subsequently, for 3 minutes during an isometric exercise at 30% of maximal voluntary contraction (Jamar®). At rest, the FH+ and FH- groups present similar mean blood pressure (83 ± 7 versus 83 ± 5 mmHg, p = 0.96), heart rate (69 ± 8 bpm versus 66 ± 7 bpm, p = 0.18), forearm blood flow (3 ± 1 mL/min/100 mL versus 2.7 ± 1 mL/min/100 mL, p = 0.16), and peripheral vascular resistance (30 ± 9 units versus 34±9 units, p = 0.21), respectively. Both groups showed a significant and similar increase in mean blood pressure (∆ = 15 ± 7 mmHg versus 14 ± 7 mmHg, p = 0.86), heart rate (∆ = 12 ± 8 bpm versus 13 ± 7 bpm, p = 0.86), and forearm blood flow (∆ = 0.8 ± 1.2 mL/min/100 mL versus 1.4 ± 1.1 mL/min/100 mL, p = 0.25), respectively, during exercise. However, individuals in the FH+ group showed no reduction in peripheral vascular resistance during exercise, which was observed in the FH- group (∆ = -0.4 ± 8.6 units versus -7.2 ± 6.3 units, p = 0.03). Normotensive individuals with a family history of hypertension present an impaired peripheral vascular resistance response to exercise. O histórico familiar para hipertensão arterial está relacionado a anormalidades vasculares e autonômicas, bem como disfunções no comportamento neuro-hemodinâmico durante o exercício físico. Testar a hipótese de que indivíduos normotensos com histórico familiar de hipertensão arterial apresentam resposta prejudicada da resistência vascular periférica durante o exercício físico. Foram avaliados 37 normotensos de ambos os sexos, sedentários, eutróficos e não tabagistas, sendo 23 com histórico familiar positivo (HF+, 24 ± 3 anos) e 14 com histórico familiar negativo (HF-, 27 ± 5 anos) para hipertensão arterial. Foram identificados pressão arterial, frequência cardíaca (DIXTAL®), fluxo sanguíneo muscular do antebraço e resistência vascular periférica local (Hokanson®) por 3 minutos durante o repouso e, em seguida, 3 minutos durante exercício isométrico de preensão palmar a 30% da contração voluntária máxima (Jamar®). Em repouso, os grupos HF+ e HF- apresentaram valores semelhantes de pressão arterial média (83 ± 7 mmHg versus 83 ± 5 mmHg, p = 0,96), frequência cardíaca (69 ± 8 bpm versus 66 ± 7 bpm, p = 0,18), fluxo sanguíneo muscular (3 ± 1 mL/min/199 mL versus 2,7 ± 1 mL/min/100 mL, p = 0,16) e resistência vascular periférica (30 ± 9 unidades versus 34 ± 9 unidades, p = 0,21), respectivamente. Durante o exercício, HF+ e HF- mostraram aumento significativo e semelhante da pressão arterial média (∆ = 15 ± 7 mmHg versus 14 ± 7 mmHg, p = 0,86), frequência cardíaca (∆ = 12 ± 8 bpm versus 13 ± 7 bpm, p = 0,86) e fluxo sanguíneo muscular (∆ = 0,8 ± 1,2 mL/min/100 mL versus 1,4 ± 1,1 mL/min/100 mL, p = 0,25), respectivamente. Entretanto, no grupo HF+ não houve redução significativa da resistência vascular periférica durante o exercício, fato que ocorreu no grupo HF- (∆ = -0,4 ± 8,6 unidades versus -7,2 ± 6,3 unidades, p = 0,03). Indivíduos normotensos com histórico familiar de hipertensão arterial apresentam resposta prejudicada da resistência vascular periférica durante o exercício físico.

  19. A Comparison of Theory-Based and Experimentally Determined Myocardial Signal Intensity Correction Methods in First-Pass Perfusion Magnetic Resonance Imaging.

    PubMed

    Fluckiger, Jacob U; Benefield, Brandon C; Bakhos, Lara; Harris, Kathleen R; Lee, Daniel C

    2015-01-01

    To evaluate the impact of correcting myocardial signal saturation on the accuracy of absolute myocardial blood flow (MBF) measurements. We performed 15 dual bolus first-pass perfusion studies in 7 dogs during global coronary vasodilation and variable degrees of coronary artery stenosis. We compared microsphere MBF to MBF calculated from uncorrected and corrected MRI signal. Four correction methods were tested, two theoretical methods (Th1 and Th2) and two empirical methods (Em1 and Em2). The correlations with microsphere MBF (n = 90 segments) were: uncorrected (y = 0.47x + 1.1, r = 0.70), Th1 (y = 0.53x + 1.0, r = 0.71), Th2 (y = 0.62x + 0.86, r = 0.73), Em1 (y = 0.82x + 0.86, r = 0.77), and Em2 (y = 0.72x + 0.84, r = 0.75). All corrected methods were not significantly different from microspheres, while uncorrected MBF values were significantly lower. For the top 50% of microsphere MBF values, flows were significantly underestimated by uncorrected SI (31%), Th1 (25%), and Th2 (19%), while Em1 (1%), and Em2 (9%) were similar to microsphere MBF. Myocardial signal saturation should be corrected prior to flow modeling to avoid underestimation of MBF by MR perfusion imaging.

  20. Effects of cardiac oscillations and lung volume on acinar gas mixing during apnea

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mackenzie, C.F.; Skacel, M.; Barnas, G.M.

    1990-05-01

    We evaluated the importance of cardiogenic gas mixing in the acini of 13 dogs during 2 min of apnea. 133Xe (1-2 mCi in 4 ml of saline) was injected into an alveolar region through an occluded pulmonary artery branch, and washout was measured by gamma scintillation scanning during continued occlusion or with blood flow reinstated. The monoexponential rate constant for Xe washout (XeW) was -0.4 +/- 0.08 (SE) min-1 at functional residual capacity (FRC) with no blood flow in the injected region. It decreased by more than half at lung volumes 500 ml above and 392 ml below FRC. Withmore » intact pulmonary blood flow, XeW was -1.0 +/- 0.08 (SE) min-1 at FRC, and it increased with decreasing lung volume. However, if calculated Xe uptake by the blood was subtracted from the XeW measured with blood flow intact, resulting values at FRC and at FRC + 500 ml were not different from XeW with no blood flow. Reasonable calculation of Xe blood uptake at 392 ml below FRC was not possible because airway closure, increased shunt, and other factors affect XeW. After death, no significant XeW could be measured, which suggests that XeW caused by molecular diffusion was small. We conclude that (1) the effect of heart motion on the lung parenchyma increases acinar gas mixing during apnea, (2) this effect diminishes above or below FRC, and (3) there is probably no direct effect of pulmonary vascular pulsatility on acinar gas mixing.« less

  1. Continuous flow electrophoresis: The effect of sample concentration on throughput and resolution in an upward flowing system

    NASA Technical Reports Server (NTRS)

    Jandebeur, T. S.

    1980-01-01

    The effect of sample concentration on throughput and resolution in a modified continuous particle electrophoresis (CPE) system with flow in an upward direction is investigated. Maximum resolution is achieved at concentrations ranging from 2 x 10 to the 8th power cells/ml to 8 x 10 to the 8th power cells/ml. The widest peak separation is at 2 x 10 to the 8th power cells/ml; however, the sharpest peaks and least overlap between cell populations is at 8 x 10 to the 8th power cells/ml. Apparently as a result of improved electrophoresis cell performance due to coasting the chamber with bovine serum albumin, changing the electrode membranes and rinse, and lowering buffer temperatures, sedimentation effects attending to higher concentrations are diminished. Throughput as measured by recovery of fixed cells is diminished at the concentrations judged most likely to yield satisfactory resolution. The tradeoff appears to be improved recovery/throughput at the expense of resolution.

  2. Uroflowmetry nomograms for healthy children 5 to 15 years old.

    PubMed

    Gupta, Dheeraj Kumar; Sankhwar, Satya Narayan; Goel, Apul

    2013-09-01

    We determined flow rates and generated flow rate-voided volume nomograms based on healthy children 5 to 15 years old voiding spontaneously in their natural environment. A total of 824 healthy school children of both genders were enrolled. A single uroflow record from each child was evaluated. A total of 103 children with a voided volume of less than 50 ml and/or a staccato/interrupted uroflow pattern were excluded, and 721 records were analyzed. Data were evaluated using several mathematical formulas and goodness of fit was determined. Linear regression analysis was used to generate nomograms. Flow rates and voided volumes increased with increasing age, with the effect being more pronounced in girls. No significant difference was noted in uroflow rates from 5 to 10 years, but significant differences (p <0.001) started appearing at 11 to 15 years. Also no significant difference was noted in uroflow rates among children 11 to 15 years. Therefore, 2 age groups were designated, with group 1 consisting of patients 5 to 10 years old and group 2 consisting of patients 11 to 15 years old. There were 222 boys and 122 girls in group 1 and 240 boys and 137 girls in group 2. In group 1 the maximum and average ± SD flow rates were 15.26 ± 4.54 ml per second and 7.68 ± 3.26 ml per second, respectively, for boys and 17.98 ± 6.06 ml per second and 9.19 ± 4.23 ml per second, respectively, for girls. In group 2 these rates were 22.50 ± 7.24 ml per second and 10.78 ± 4.03 ml per second, respectively, for boys and 27.16 ± 9.37 ml per second and 13.48 ± 5.21 ml per second, respectively, for girls. This large study, which expands the scant existing literature on uroflow parameters in healthy children, will hopefully promote wider application of uroflowmetry testing in the pediatric population. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  3. Efficacy of Transcutaneous Electric Nerve Stimulation on Parotid Saliva Flow Rate in Relation to Age and Gender

    PubMed Central

    Dhillon, Manu; M Raju, Srinivasa; S Mohan, Raviprakash; Tomar, Divya

    2016-01-01

    Statement of the Problem Treatment with salivary substitutes and stimulation of salivary flow by either mechanical or pharmacologic methods has side effects and only provides symptomatic relief but no long-lasting results. Purpose To assess the effectiveness of extraoral transcutaneous electric nerve stimulation (TENS) as a mean of stimulating salivary function in healthy adult subjects; as well as to determine the gender and age-dependent changes in salivary flow rates of unstimulated and stimulated parotid saliva. Materials and Method Hundred patients were divided into two groups; Group I aged 20-40 and Group II aged ≥ 60 years. The TENS electrode pads were externally placed on the skin overlying the parotid glands. Unstimulated and stimulated parotid saliva was collected for 5 minutes each by using standardized collection techniques. Results Eighty seven of 100 subjects demonstrated increased salivary flow when stimulated via the TENS unit. Ten experienced no increase and 3 experienced a decrease. The mean unstimulated salivary flow rate was 0.01872 ml/min in Group I and 0.0088 ml/min in Group II. The mean stimulated salivary flow rate was 0.03084 ml/min (SD= 0.01248) in Group I, and 0.01556 ml/min (SD 0.0101) in Group II. After stimulation, the amount of salivary flow increased significantly in both groups (p< 0.001). Statistical comparison of the two groups revealed them to be significantly different (p< 0.001), with Group I producing more saliva. Gender-wise, no statistically significant difference was seen among the subjects in Group I (p = 0.148), and those in Group II (p= 0.448). Out of 12 subjects with 0 baseline flows, 7 continued to have no flow. Five subjects observed side effects, although minimal and transient. Conclusion The TENS unit was effective in increasing parotid gland salivary flow in healthy subjects. There was age-related but no gender-related variability in parotid salivary flow rate. PMID:27602390

  4. Efficacy of Transcutaneous Electric Nerve Stimulation on Parotid Saliva Flow Rate in Relation to Age and Gender.

    PubMed

    Dhillon, Manu; M Raju, Srinivasa; S Mohan, Raviprakash; Tomar, Divya

    2016-09-01

    Treatment with salivary substitutes and stimulation of salivary flow by either mechanical or pharmacologic methods has side effects and only provides symptomatic relief but no long-lasting results. To assess the effectiveness of extraoral transcutaneous electric nerve stimulation (TENS) as a mean of stimulating salivary function in healthy adult subjects; as well as to determine the gender and age-dependent changes in salivary flow rates of unstimulated and stimulated parotid saliva. Hundred patients were divided into two groups; Group I aged 20-40 and Group II aged ≥ 60 years. The TENS electrode pads were externally placed on the skin overlying the parotid glands. Unstimulated and stimulated parotid saliva was collected for 5 minutes each by using standardized collection techniques. Eighty seven of 100 subjects demonstrated increased salivary flow when stimulated via the TENS unit. Ten experienced no increase and 3 experienced a decrease. The mean unstimulated salivary flow rate was 0.01872 ml/min in Group I and 0.0088 ml/min in Group II. The mean stimulated salivary flow rate was 0.03084 ml/min (SD= 0.01248) in Group I, and 0.01556 ml/min (SD 0.0101) in Group II. After stimulation, the amount of salivary flow increased significantly in both groups (p< 0.001). Statistical comparison of the two groups revealed them to be significantly different (p< 0.001), with Group I producing more saliva. Gender-wise, no statistically significant difference was seen among the subjects in Group I (p = 0.148), and those in Group II (p= 0.448). Out of 12 subjects with 0 baseline flows, 7 continued to have no flow. Five subjects observed side effects, although minimal and transient. The TENS unit was effective in increasing parotid gland salivary flow in healthy subjects. There was age-related but no gender-related variability in parotid salivary flow rate.

  5. Hybrid Epitaxial Structures for Spintronics

    DTIC Science & Technology

    2002-06-03

    superlat- magnetic resonance (NMR) measurements on the short tice have a perpendicular magnetization, which are range chemical order in combination...Groot, EM. Mueller, PG. van Engen , K.H.J. Buschow, [76] EG. Monzon, M.L. Roukes, J. Magn. Magn. Mater. 198-199 Phys. Rev. Lett. 50 (1983) 2024-2027

  6. Effect of lower limb compression on blood flow and performance in elite wheelchair rugby athletes

    PubMed Central

    Vaile, Joanna; Stefanovic, Brad; Askew, Christopher D.

    2016-01-01

    Objective To investigate the effects of compression socks worn during exercise on performance and physiological responses in elite wheelchair rugby athletes. Design In a non-blinded randomized crossover design, participants completed two exercise trials (4 × 8 min bouts of submaximal exercise, each finishing with a timed maximal sprint) separated by 24 hr, with or without compression socks. Setting National Sports Training Centre, Queensland, Australia. Participants Ten national representative male wheelchair rugby athletes with cervical spinal cord injuries volunteered to participate. Interventions Participants wore medical grade compression socks on both legs during the exercise task (COMP), and during the control trial no compression was worn (CON). Outcome Measures The efficacy of the compression socks was determined by assessments of limb blood flow, core body temperature, heart rate, and ratings of perceived exertion, perceived thermal strain, and physical performance. Results While no significant differences between conditions were observed for maximal sprint time, average lap time was better maintained in COMP compared to CON (P<0.05). Lower limb blood flow increased from pre- to post-exercise by the same magnitude in both conditions (COMP: 2.51 ± 2.34; CON: 2.20 ± 1.85 ml.100 ml.−1min−1), whereas there was a greater increase in upper limb blood flow pre- to post-exercise in COMP (10.77 ± 8.24 ml.100 ml.−1min−1) compared to CON (6.21 ± 5.73 ml.100 ml.−1min−1; P < 0.05). Conclusion These findings indicate that compression socks worn during exercise is an effective intervention for maintaining submaximal performance during wheelchair exercise, and this performance benefit may be associated with an augmentation of upper limb blood flow. PMID:25582434

  7. Cerebral blood flow and carbon dioxide reactivity in children with bacterial meningitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ashwal, S.; Stringer, W.; Tomasi, L.

    1990-10-01

    We examined total and regional cerebral blood flow (CBF) by stable xenon computed tomography in 20 seriously ill children with acute bacterial meningitis to determine whether CBF was reduced and to examine the changes in CBF during hyperventilation. In 13 children, total CBF was normal (62 +/- 20 ml/min/100 gm) but marked local variability of flow was seen. In five other children, total CBF was significantly reduced (26 +/- 10 ml/min/100 gm; p less than 0.05), with flow reduced more in white matter (8 +/- 5 ml/min/100 gm) than in gray matter (30 +/- 15 ml/min/100 gm). Autoregulation of CBFmore » appeared to be present in these 18 children within a range of mean arterial blood pressure from 56 to 102 mm Hg. In the remaining two infants, brain dead within the first 24 hours, total flow was uniformly absent, averaging 3 +/- 3 ml/min/100 gm. In seven children, CBF was determined at two carbon dioxide tension (PCO2) levels: 40 (+/- 3) mm Hg and 29 (+/- 3) mm Hg. In six children, total CBF decreased 33%, from 52 (+/- 25) to 35 (+/- 15) ml/min/100 gm; the mean percentage of change in CBF per millimeter of mercury of PCO2 was 3.0%. Regional variability of perfusion to changes in PCO2 was marked in all six children. The percentage of change in CBF per millimeter of mercury of PCO2 was similar in frontal gray matter (3.1%) but higher in white matter (4.5%). In the seventh patient a paradoxical response was observed; total and regional CBF increased 25% after hyperventilation. Our findings demonstrate that (1) CBF in children with bacterial meningitis may be substantially decreased globally, with even more variability noted regionally, (2) autoregulation of CBF is preserved, (3) CBF/CO2 responsitivity varies among patients and in different regions of the brain in the same patient, and (4) hyperventilation can reduce CBF below ischemic thresholds.« less

  8. Assessing the potential for improved scramjet performance through application of electromagnetic flow control

    NASA Astrophysics Data System (ADS)

    Lindsey, Martin Forrester

    Sustained hypersonic flight using scramjet propulsion is the key technology bridging the gap between turbojets and the exoatmospheric environment where a rocket is required. Recent efforts have focused on electromagnetic (EM) flow control to mitigate the problems of high thermomechanical loads and low propulsion efficiencies associated with scramjet propulsion. This research effort is the first flight-scale, three-dimensional computational analysis of a realistic scramjet to determine how EM flow control can improve scramjet performance. Development of a quasi-one dimensional design tool culminated in the first open source geometry of an entire scramjet flowpath. This geometry was then tested extensively with the Air Force Research Laboratory's three-dimensional Navier-Stokes and EM coupled computational code. As part of improving the model fidelity, a loosely coupled algorithm was developed to incorporate thermochemistry. This resulted in the only open-source model of fuel injection, mixing and combustion in a magnetogasdynamic (MGD) flow controlled engine. In addition, a control volume analysis tool with an electron beam ionization model was presented for the first time in the context of the established computational method used. Local EM flow control within the internal inlet greatly impacted drag forces and wall heat transfer but was only marginally successful in raising the average pressure entering the combustor. The use of an MGD accelerator to locally increase flow momentum was an effective approach to improve flow into the scramjet's isolator. Combustor-based MGD generators proved superior to the inlet generator with respect to power density and overall engine efficiency. MGD acceleration was shown to be ineffective in improving overall performance, with all of the bypass engines having approximately 33% more drag than baseline and none of them achieving a self-powered state.

  9. Beyond-laboratory-scale prediction for channeling flows through subsurface rock fractures with heterogeneous aperture distributions revealed by laboratory evaluation

    NASA Astrophysics Data System (ADS)

    Ishibashi, Takuya; Watanabe, Noriaki; Hirano, Nobuo; Okamoto, Atsushi; Tsuchiya, Noriyoshi

    2015-01-01

    The present study evaluates aperture distributions and fluid flow characteristics for variously sized laboratory-scale granite fractures under confining stress. As a significant result of the laboratory investigation, the contact area in fracture plane was found to be virtually independent of scale. By combining this characteristic with the self-affine fractal nature of fracture surfaces, a novel method for predicting fracture aperture distributions beyond laboratory scale is developed. Validity of this method is revealed through reproduction of the results of laboratory investigation and the maximum aperture-fracture length relations, which are reported in the literature, for natural fractures. The present study finally predicts conceivable scale dependencies of fluid flows through joints (fractures without shear displacement) and faults (fractures with shear displacement). Both joint and fault aperture distributions are characterized by a scale-independent contact area, a scale-dependent geometric mean, and a scale-independent geometric standard deviation of aperture. The contact areas for joints and faults are approximately 60% and 40%. Changes in the geometric means of joint and fault apertures (µm), em, joint and em, fault, with fracture length (m), l, are approximated by em, joint = 1 × 102 l0.1 and em, fault = 1 × 103 l0.7, whereas the geometric standard deviations of both joint and fault apertures are approximately 3. Fluid flows through both joints and faults are characterized by formations of preferential flow paths (i.e., channeling flows) with scale-independent flow areas of approximately 10%, whereas the joint and fault permeabilities (m2), kjoint and kfault, are scale dependent and are approximated as kjoint = 1 × 10-12 l0.2 and kfault = 1 × 10-8 l1.1.

  10. Fractal regional myocardial blood flows pattern according to metabolism, not vascular anatomy

    PubMed Central

    Yipintsoi, Tada; Kroll, Keith

    2015-01-01

    Regional myocardial blood flows are markedly heterogeneous. Fractal analysis shows strong near-neighbor correlation. In experiments to distinguish control by vascular anatomy vs. local vasomotion, coronary flows were increased in open-chest dogs by stimulating myocardial metabolism (catecholamines + atropine) with and without adenosine. During control states mean left ventricular (LV) myocardial blood flows (microspheres) were 0.5–1 ml·g−1·min−1 and increased to 2–3 ml·g−1·min−1 with catecholamine infusion and to ∼4 ml·g−1·min−1 with adenosine (Ado). Flow heterogeneity was similar in all states: relative dispersion (RD = SD/mean) was ∼25%, using LV pieces 0.1–0.2% of total. During catecholamine infusion local flows increased in proportion to the mean flows in 45% of the LV, “tracking” closely (increased proportionately to mean flow), while ∼40% trended toward the mean. Near-neighbor regional flows remained strongly spatially correlated, with fractal dimension D near 1.2 (Hurst coefficient 0.8). The spatial patterns remain similar at varied levels of metabolic stimulation inferring metabolic dominance. In contrast, adenosine vasodilation increased flows eightfold times control while destroying correlation with the control state. The Ado-induced spatial patterns differed from control but were self-consistent, inferring that with full vasodilation the relaxed arterial anatomy dominates the distribution. We conclude that vascular anatomy governs flow distributions during adenosine vasodilation but that metabolic vasoregulation dominates in normal physiological states. PMID:26589329

  11. Fractal regional myocardial blood flows pattern according to metabolism, not vascular anatomy.

    PubMed

    Yipintsoi, Tada; Kroll, Keith; Bassingthwaighte, James B

    2016-02-01

    Regional myocardial blood flows are markedly heterogeneous. Fractal analysis shows strong near-neighbor correlation. In experiments to distinguish control by vascular anatomy vs. local vasomotion, coronary flows were increased in open-chest dogs by stimulating myocardial metabolism (catecholamines + atropine) with and without adenosine. During control states mean left ventricular (LV) myocardial blood flows (microspheres) were 0.5-1 ml·g(-1)·min(-1) and increased to 2-3 ml·g(-1)·min(-1) with catecholamine infusion and to ∼4 ml·g(-1)·min(-1) with adenosine (Ado). Flow heterogeneity was similar in all states: relative dispersion (RD = SD/mean) was ∼25%, using LV pieces 0.1-0.2% of total. During catecholamine infusion local flows increased in proportion to the mean flows in 45% of the LV, "tracking" closely (increased proportionately to mean flow), while ∼40% trended toward the mean. Near-neighbor regional flows remained strongly spatially correlated, with fractal dimension D near 1.2 (Hurst coefficient 0.8). The spatial patterns remain similar at varied levels of metabolic stimulation inferring metabolic dominance. In contrast, adenosine vasodilation increased flows eightfold times control while destroying correlation with the control state. The Ado-induced spatial patterns differed from control but were self-consistent, inferring that with full vasodilation the relaxed arterial anatomy dominates the distribution. We conclude that vascular anatomy governs flow distributions during adenosine vasodilation but that metabolic vasoregulation dominates in normal physiological states. Copyright © 2016 the American Physiological Society.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rajagopalan, B.; Raine, A.E.; Cooper, R.

    The intravenous /sup 133/xenon injection method was used to estimate global cerebral blood flow before and after treatment with captopril in nine patients with severe heart failure. The pretreatment mean blood pressure was 94.9 mm Hg (S.D. 13.9) and fell to 85.1 mm Hg (S.D. 18.1) after treatment with captopril for between four and 15 days. The cerebral blood flow before captopril was 61.1 ml/100 g per minute (S.D. 6.9), which was less than the value of 75.8 ml/100 g per minute found in control subjects. After treatment with captopril the cerebral blood flow increased to 73.8 ml/100 g permore » minute (S.D. 11.8, p less than 0.01). The fraction of carbon dioxide in the expired air was not significantly different in the two studies (4.1 +/- 0.88 versus 3.97 +/- 0.65). It is concluded that cerebral blood flow is reduced in severe heart failure and can be restored by treatment with captopril, but the reasons for the reduced flow and its improvement after converting enzyme inhibition are not known.« less

  13. Salivary flow rate and xerostomia in patients with type I and II diabetes mellitus

    PubMed Central

    Hoseini, Amineh; Mirzapour, Ali; Bijani, Ali; Shirzad, Atena

    2017-01-01

    Background Diabetes mellitus is one of the most prevalent metabolic diseases, with complications such as decreased salivary flow rate and xerostomia. Objective This study aimed to determine the salivary flow rate and xerostomia in type I and II diabetic patients in comparison with healthy controls. Methods This case-control study was performed on diabetic patients of a private office in Babol, Iran, between May 2015 and October 2016. This study involved two study groups (type I and II diabetes, with 40 in each group) and two control groups (control I and II, with 35 in each group) which were age- and sex-matched with the related study groups. They were all selected through simple sampling. Unstimulated whole saliva was collected through Navazesh method and the salivary flow rate was measured (ml/min). Xerostomia was evaluated via Fox’s test. Moreover, the patients’ data were recorded including age, sex, disease duration, type of diabetes, fasting blood glucose (FBG) and HbA1C. The obtained data were statistically analyzed by using SPSS version 17. Independent-samples t-test, Chi-square, Pearson correlation and multiple comparison post-hoc tests were employed as appropriated. p<0.05 was considered significant. Results The mean salivary flow rate in type I diabetics (0.35±0.11 ml/min) was lower than that in control I (0.50±0.07 ml/min) (p=0.01). The same difference was observed between type II diabetics (0.37±0.13 ml/min) and control II groups (0.47±0.11 ml/min) (p=0.01). No significant difference was observed in the salivary flow rate between type I and II diabetics (p=0.345). Furthermore, xerostomia was higher in type I (2.70±2.50, 1.17±1.60) and II (2.65±2.20–1.62±1.50) diabetics compared with the related control groups (p=0.01), (p=0.02). Conclusion Type I, II diabetic patients revealed lower salivary flow rate and higher xerostomia compared with healthy controls. The salivary flow rate and xerostomia had inverse correlation. PMID:29038704

  14. Salivary flow rate and xerostomia in patients with type I and II diabetes mellitus.

    PubMed

    Hoseini, Amineh; Mirzapour, Ali; Bijani, Ali; Shirzad, Atena

    2017-09-01

    Diabetes mellitus is one of the most prevalent metabolic diseases, with complications such as decreased salivary flow rate and xerostomia. This study aimed to determine the salivary flow rate and xerostomia in type I and II diabetic patients in comparison with healthy controls. This case-control study was performed on diabetic patients of a private office in Babol, Iran, between May 2015 and October 2016. This study involved two study groups (type I and II diabetes, with 40 in each group) and two control groups (control I and II, with 35 in each group) which were age- and sex-matched with the related study groups. They were all selected through simple sampling. Unstimulated whole saliva was collected through Navazesh method and the salivary flow rate was measured (ml/min). Xerostomia was evaluated via Fox's test. Moreover, the patients' data were recorded including age, sex, disease duration, type of diabetes, fasting blood glucose (FBG) and HbA1C. The obtained data were statistically analyzed by using SPSS version 17. Independent-samples t-test, Chi-square, Pearson correlation and multiple comparison post-hoc tests were employed as appropriated. p<0.05 was considered significant. The mean salivary flow rate in type I diabetics (0.35±0.11 ml/min) was lower than that in control I (0.50±0.07 ml/min) (p=0.01). The same difference was observed between type II diabetics (0.37±0.13 ml/min) and control II groups (0.47±0.11 ml/min) (p=0.01). No significant difference was observed in the salivary flow rate between type I and II diabetics (p=0.345). Furthermore, xerostomia was higher in type I (2.70±2.50, 1.17±1.60) and II (2.65±2.20-1.62±1.50) diabetics compared with the related control groups (p=0.01), (p=0.02). Type I, II diabetic patients revealed lower salivary flow rate and higher xerostomia compared with healthy controls. The salivary flow rate and xerostomia had inverse correlation.

  15. Evaluation of the efficiency of a new hollow fiber plasmapheresis filter.

    PubMed

    Orlandini, G C; Margaria, R

    1983-07-01

    Plasma separation for plasma exchange or plasma treatment has, until now, been obtained prevalently by centrifugal separators. Recently, filters capable of continuously separating the plasma have been proposed. We have evaluated, both in vivo and ex vivo, the efficiency of a plasma separating filter (BT 900, Dideco, Mirandola, Italy) incorporating polypropylene hollow fibers with a pore size of 0.55 micron (PS 510 W, Membrana, Wuppertal, Germany) and an effective surface of 0.23 m2, using two hemodialysis blood pumps. Ex vivo, (bovine blood) at a blood flow (QB) of 100 ml/min, 47 +/- 2.8 ml/min of plasma were obtained in the first hour and 34 +/- 3.1 ml/min in the second hour. The Sieving coefficient was 100 for albumin and IgG, 98.4 for IgA and 92.3 for IgM. Neither hemolysis nor platelet contamination were observed. In vivo, 35 treatment were performer on 19 patients affected with mixed essential cryoglobulinemia, autoimmune glomerulonephritis, Wegener disease, thrombotic thrombocytopenic microangiopathy and rheumatoid arthritis. There were no clinical complications and the treatment was always well tolerated. A mean of 2064 +/- 400 ml of plasma was obtained in 103.7 +/- 29 minutes. The plasma flow was correlated (p less than 0.001) with the blood flow (13.4 ml/min at QB = 30 ml/min; 29 ml/min at QB = 100 ml/min). In some cases, immune complexes were found in the plasma removed by the filter (conglutinin method), confirming the membrane permeability to these high weight molecules. The use of hollow fibers to separate formed elements of blood from plasma has a brief history (1, 5).(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Locked Nucleic Acid Flow Cytometry-fluorescence in situ Hybridization (LNA flow-FISH): A Method for Bacterial Small RNA Detection

    DTIC Science & Technology

    2012-01-10

    flow cytometry, locked nucleic acid, sRNA, Vibrio , Date Published: 1/10/2012 This is an open-access article distributed under the terms of the Creative...solubilization process to maintain a 10 mL volume. Aliquot the 60% dextran sulfate solution and store at -20 °C until use. 1. Harvest 1x108 cells of...bioluminescent Vibrio campbellii or your bacteria of interest and transfer them into a 1.5 mL microcentrifuge tube. This quantity of cells provides

  17. Effect of small flow reversals on aerosol mixing in the alveolar region of the human lung.

    PubMed

    Darquenne, Chantal; Prisk, G Kim

    2004-12-01

    It has been suggested that irreversibility of alveolar flow combined with a stretched and folded pattern of streamlines can lead to a sudden increase in mixing in the lung. To determine whether this phenomenon is operative in the human lung in vivo, we performed a series of bolus studies with a protocol designed to induce complex folding patterns. Boli of 0.5- and 1-microm-diameter particles were inhaled at penetration volumes (V(p)) of 300 and 1,200 ml in eight subjects during short periods of microgravity aboard the National Aeronautics and Space Administration Microgravity Research Aircraft. Inspiration was from residual volume to 1 liter above 1 G functional residual capacity. This was followed by a 10-s breathhold, during which up to seven 100-ml flow reversals (FR) were imposed at V(p) = 300 ml and up to four 500-ml FR at V(p) = 1,200 ml, and by an expiration to residual volume. Bolus dispersion and deposition were calculated from aerosol concentration and flow rate continuously monitored at the mouth. There was no significant increase in dispersion and deposition with increasing FR except for dispersion between 0 and 7 FR at V(p) = 300 ml with 0.5-microm-diameter particles, and this increase was small. This suggested that either the phenomenon of stretch and fold did not occur within the number of FR we performed or that it had already occurred during the one breathing cycle included in the basic maneuver. We speculate that the phenomenon occurred during the basic maneuver, which is consistent with the high degree of dispersion and deposition observed previously in microgravity.

  18. A comparative assessment of irrigation and drainage characteristics for commercially available urethral catheters

    PubMed Central

    Davis, Niall F.; McMahon, Barry P.; Walsh, Michael; McDermott, Thomas E.D.; Thornhill, John A.; Manecksha, Rustom P.

    2017-01-01

    Introduction We aimed to investigate irrigation and drainage characteristics of commercially available urethral catheters and determined which catheter offers the best flow characteristics. Material and methods Twelve different commercially available urethral catheters from three companies (Bard™, Rusch™ and Dover™) were investigated to compare their irrigation and drainage properties. Irrigation port, drainage port and overall cross-sectional areas for a 24Fr 3-way catheter was measured and compared. The maximum (Qmax) and average (Qavg) irrigation and drainage flow rates for each catheter was measured for 20–40 seconds using uroflowmetry. The primary endpoint was to determine which catheter offers optimal irrigation and drainage parameters. Results Overall cross-sectional area, irrigation port cross-sectional area, and drainage port cross-sectional area differed significantly for each 24Fr 3-way catheter assessed (p <0.001). The 24Fr 3-way Rusch Simplastic™ catheter consistently demonstrated the greatest maximal flow rate (Qmax: 5 ±0.3 ml/s) and average flow rate (Qavg: 4.6 ±0.2 ml/s) for irrigation. The 24Fr 3-way Dover™ catheter provided the greatest drainage properties (Qmax: 19.7 ±2 ml/s; Q avg: 15.9 ±5 ml/s). In the setting of continuous bladder irrigation, the 24Fr 3-way Rusch Simplastic™ catheter provided the highest irrigation rates (Qmax: 6.6 ±1.8 ml/s; Q avg: 4.6 ±0.9 ml/s). Conclusions Three-way catheters demonstrate significant differences in their irrigation and drainage characteristics. The type of catheter selected should be based on the appropriate prioritization of efficient bladder irrigation versus efficient bladder drainage. PMID:29410890

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tamaki, N.; Alpert, N.M.; Rabito, C.A.

    The sequence and magnitude of acute changes in renal blood flow following administration of captopril were determined in a canine model of acute unilateral renal artery stenosis using rubidium-82 and positron emission tomography. Data were recorded in each of nine dogs under three conditions: 1) during a baseline control interval, 2) during renal artery stenosis, and 3) during stenosis with intravenous injection of captopril (1.2 mg/kg). Mean arterial blood pressure was 108 +/- 12 mm Hg at control, increased significantly to 125 +/- 13 mm Hg (p less than 0.01) during stenosis, and decreased to 98 +/- 13 mm/Hg (pmore » less than 0.01) after captopril infusion. Mean renal blood flow was calculated using a steady state single compartment model from the images produced by positron emission tomography. The estimated flow to the affected kidney was 3.37 +/- 1.48 ml/min/g at control, 0.86 +/- 0.62 ml/min/g during stenosis (p less than 0.01), and 0.64 +/- 0.57 ml/min/g after captopril administration (p = NS compared with precaptopril value). The estimated flow to the contralateral kidney was minimally reduced from a baseline of 3.84 +/- 0.95 to 3.24 +/- 1.13 ml/min/g (p = NS) during stenosis and increased after captopril infusion (4.08 +/- 0.94 ml/min/g; p = 0.01). These data suggest that repetitive imaging with positron emission tomography can be used to delineate acute changes in renal perfusion following captopril administration.« less

  20. EFFECT OF CHRONIC INGESTION OF WINE ON THE GLYCEMIC, LIPID AND BODY WEIGHT HOMEOSTASIS IN MICE.

    PubMed

    Brito-Filho, Sebastião Barreto de; Moura, Egberto Gaspar de; Santos, Orlando José Dos; Sauaia-Filho, Euler Nicolau; Amorim, Elias; Santana, Ewaldo Eder Carvalho; Barros-Filho, Allan Kardec Dualibe; Santos, Rennan Abud Pinheiro

    2016-01-01

    The health benefits associated with moderate wine consumption, as with ethanol and phenolic compounds, include different mechanisms still little understandable. Evaluate glycemic and weight variations, and the deposit of triglycerides, cholesterol and liver glycogen with red wine consumption. 60 ApoE knockout mice were divided into three groups of 20: Wine Group (WG), Ethanol Group (EG) and Water Group (WAG). They received daily: WG 50 ml of wine and 50 ml water; EG 6 ml ethanol and WAG 94 ml of water. All groups were followed for four months. The food intake was monitored daily, in the period from eight to ten hours and held every five days. The measurement of water intake was also made every five days. The weighing of the animals took place every ten days. The WG had higher weight increase as compared to the other groups. The concentration of hepatic triglyceride was higher in WG (57%) and the EG group was lower (31.6%, p<0.01) than the control. The concentration of cholesterol was lower in the WG (23.6%), as well as EG (24.5%, p<0.05). The concentration of glycogen was higher in WG (16%) and fasting blood glucose was higher in EG compared to the other groups but not both demonstrated a statistically significant difference. The WG increased triglyceride and WAG decreased cholesterol. The triglyceride may be increased due to the high caloric value of wine or some unknown property that led to significant increase in subcutaneous andretroperitoneal fat in mice. Os benefícios para a saúde associados ao consumo moderado de vinho, como etanol e compostos fenólicos, incluem mecanismos diferentes ainda pouco compreensíveis. Avaliar as variações da glicemia, peso e depósito de triglicrideos, colesterol e glicogênio hepático com o uso de vinho tinto. Sessenta camundongos ApoE knockout foram divididos em três grupos de 20: Grupo do Vinho (WG), grupo do Etanol (EG) Grupo Água (WAG). Cada grupo recebeu diariamente: WG 50 ml de vinho e 50 ml de água; EG 6 ml de etanol e WAG 94 ml de água. O WG teve aumento de peso mais elevado em comparação com os outros grupos. A concentração de triglicerídeos foi maior no WG (57%) e no grupo EG inferior (31,6%) do que no controle (p <0,01). A concentração de colesterol foi inferior no WG (23,6%) e no EG (24,5%, p<0,05). A concentração de glicogênio foi maior no WG (16%); a glicemia capilar foi maior no EG em comparação com os outros grupos, mas não demonstrou diferença estatisticamente significativa. Triglicerídeos ficaram aumentados no WG e o colesterol diminuiu no WAG. Os triglicerídeos podem ter aumentado devido ao alto valor calórico do vinho ou alguma propriedade desconhecida que levou ao aumento significativo da gordura subcutânea e retroperitoneal nos camundongos.

  1. Cerebral blood flow is reduced in patients with sepsis syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bowton, D.L.; Bertels, N.H.; Prough, D.S.

    The relationship between sepsis-induced CNS dysfunction and changes in brain blood flow remains unknown, and animal studies examining the influence of sepsis on cerebral blood flow (CBF) do not satisfactorily address that relationship. We measured CBF and cerebrovascular reactivity to CO/sub 2/ in nine patients with sepsis syndrome using the /sup 133/Xe clearance technique. Mean CBF was 29.6 +/- 15.8 (SD) ml/100 g.min, significantly lower than the normal age-matched value in this laboratory of 44.9 +/- 6.2 ml/100 g.min (p less than .02). This depression did not correlate with changes in mean arterial pressure. Despite the reduction in CBF, themore » specific reactivity of the cerebral vasculature to changes in CO/sub 2/ was normal, 1.3 +/- 0.9 ml/100 g.min/mm Hg. Brain blood flow is reduced in septic humans; the contribution of this reduction to the metabolic and functional changes observed in sepsis requires further study.« less

  2. Sex differences in absolute myocardial perfusion. Non-invasive H2(15)O-PET in young healthy adults.

    PubMed

    Range, Felix T; Kies, Peter; Schäfers, Klaus P; Breithardt, Günter; Schober, Otmar; Wichter, Thomas; Schäfers, Michael A

    2016-09-26

    To investigate sex differences in myocardial perfusion especially in healthy individuals since former studies are rare and findings are controversial. Participants, methods: 26 subjects were enrolled: 16 healthy women (age: 34 ±7 years) were compared with 10 healthy men (age: 34 ± 3 years; p = ns). Myocardial blood flow (MBF) and coronary vascular resistance (CVR) were quantified at rest, during adenosine infusion and cold-pressor-testing, using positron emission tomography and radioactive-labelled water (H2(15)O-PET). Women showed higher MBF than men at rest (1.10 ± 0.18 vs. 0.85 ± 0.20 ml/min/ml; p = 0.003) and cold-stress (1.39 ± 0.38 vs. 1.06 ± 0.28 ml/min/ml; p = 0.026). Corrected for rate-pressure-product, baseline findings maintained significance (1.41 ± 0.33 vs. 1.16 ± 0.19 ml/min/ml; p = 0.024). CVR was lower in women at baseline (81 ± 14 vs. 107 ± 22 mmHg*ml(-1)*min*ml; p = 0.006) and during cold-pressor-testing (71 ± 17 vs. 91 ± 20 mmHg*ml(-1)*min*ml; p = 0.013). Under adenosine neither maximal MBF (4.06 ± 1.0 vs. 3.91 ± 0.88 ml/min/ml; p = ns) nor coronary flow reserve (3.07 ± 1.12 vs. 3.44 ± 0.92; p = ns) nor CVR (24 ± 8 vs. 24 ± 6 mmHg*ml(-1)*min*ml; p = ns) showed sex-related differences. Women show higher myocardial perfusion and lower coronary vascular resistance than men in physiologic states. Maximum perfusion and vasodilation under adenosine are not sex-specific.

  3. Brain microvascular function during cardiopulmonary bypass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sorensen, H.R.; Husum, B.; Waaben, J.

    1987-11-01

    Emboli in the brain microvasculature may inhibit brain activity during cardiopulmonary bypass. Such hypothetical blockade, if confirmed, may be responsible for the reduction of cerebral metabolic rate for glucose observed in animals subjected to cardiopulmonary bypass. In previous studies of cerebral blood flow during bypass, brain microcirculation was not evaluated. In the present study in animals (pigs), reduction of the number of perfused capillaries was estimated by measurements of the capillary diffusion capacity for hydrophilic tracers of low permeability. Capillary diffusion capacity, cerebral blood flow, and cerebral metabolic rate for glucose were measured simultaneously by the integral method, different tracersmore » being used with different circulation times. In eight animals subjected to normothermic cardiopulmonary bypass, and seven subjected to hypothermic bypass, cerebral blood flow, cerebral metabolic rate for glucose, and capillary diffusion capacity decreased significantly: cerebral blood flow from 63 to 43 ml/100 gm/min in normothermia and to 34 ml/100 gm/min in hypothermia and cerebral metabolic rate for glucose from 43.0 to 23.0 mumol/100 gm/min in normothermia and to 14.1 mumol/100 gm/min in hypothermia. The capillary diffusion capacity declined markedly from 0.15 to 0.03 ml/100 gm/min in normothermia but only to 0.08 ml/100 gm/min in hypothermia. We conclude that the decrease of cerebral metabolic rate for glucose during normothermic cardiopulmonary bypass is caused by interruption of blood flow through a part of the capillary bed, possibly by microemboli, and that cerebral blood flow is an inadequate indicator of capillary blood flow. Further studies must clarify why normal microvascular function appears to be preserved during hypothermic cardiopulmonary bypass.« less

  4. Use of O-15 water and C-11 butanol to measure cerebral blood flow (CBF) and water permeability with positron emission tomography (PET)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herscovitch, P.; Raichle, M.E.; Kilbourn, M.R.

    1985-05-01

    Tracers used to measure CBF with PET and the Kety autoradiographic approach should freely cross the blood-brain barrier. 0-15 water, which is not freely permeable, may underestimate CBF, especially at higher flows. The authors determined this under-estimation relative to flow measured with a freely diffusible tracer, C-11 butanol and used these data to calculate the extraction (E) and permeability surface area product (PS) for 0-15 water. Paired flow measurements were made with 0-15 water (CBF-wat) and C-11 butanol (CBF-but) in eight normal human subjects. Average CBF-but, 55.6 ml/(min . 100g) was significantly greater than CBF-water, 47.6 ml/(min . 100g). Themore » ratio of regional gray matter (GM) flow to white matter (WM) flow was significantly greater with C-11 butanol, indicating a greater underestimation of CBF with 0-15 water in the higher flow GM. Average E for water was 0.92 in WM and 0.82 in GM. The mean PS in GM, 148 ml/(min . 100g), was significantly greater than in WM, 94 ml/(min . 100g). Simulation studies demonstrated that a measurement error in CBF-wat or CBF-but causes an approximately equivalent error in E but a considerably larger error in PS due to the sensitivity of the equation, PS=-CBF . ln(1-E), to variations in E. Modest errors in E and PS result from tissue heterogeneity that occurs due to the limited spatial resolution of PET. The authors' measurements of E and PS for water are similar to data obtained by more invasive methods and demonstrate the ability of PET to measure brain water permeability.« less

  5. Effect of fluoroquinolone on the enhanced nitric oxide-induced peripheral vasodilation seen in cirrhosis.

    PubMed

    Chin-Dusting, J P; Rasaratnam, B; Jennings, G L; Dudley, F J

    1997-12-01

    In patients with cirrhosis, portosystemic shunts allow intestinal bacteria and endotoxin to enter the systemic circulation. Endotoxemia may induce increased synthesis of nitric oxide, thereby contributing to arterial vasodilation. To test the hypothesis that the antibiotic norfloxacin blocks the effects of nitric oxide. Placebo-controlled, double-blind, crossover study. Alfred Hospital, Melbourne, Australia. 9 patients with alcohol-related cirrhosis and 10 healthy controls. Norfloxacin, 400 mg twice daily, for 4 weeks. Peripheral blood flow was measured by using forearm venous occlusion plethysmography. Basal forearm blood flow was higher in patients with cirrhosis than in controls (3.69 +/- 0.27 mL/100 mL per minute and 2.47 +/- 0.40 mL/100 mL per minute; P = 0.014) but returned toward normal after norfloxacin was given (2.64 +/- 0.31 mL/100 mL of tissue per minute in patients with cirrhosis). Responses to NG-monomethyl-L-arginine were greater in patients with cirrhosis but returned to normal after norfloxacin was given. Bacterial endotoxemia in patients with cirrhosis induces increased synthesis of nitric oxide that can be corrected with norfloxacin.

  6. Optimising resolution for a preparative separation of Chinese herbal medicine using a surrogate model sample system.

    PubMed

    Ye, Haoyu; Ignatova, Svetlana; Peng, Aihua; Chen, Lijuan; Sutherland, Ian

    2009-06-26

    This paper builds on previous modelling research with short single layer columns to develop rapid methods for optimising high-performance counter-current chromatography at constant stationary phase retention. Benzyl alcohol and p-cresol are used as model compounds to rapidly optimise first flow and then rotational speed operating conditions at a preparative scale with long columns for a given phase system using a Dynamic Extractions Midi-DE centrifuge. The transfer to a high value extract such as the crude ethanol extract of Chinese herbal medicine Millettia pachycarpa Benth. is then demonstrated and validated using the same phase system. The results show that constant stationary phase modelling of flow and speed with long multilayer columns works well as a cheap, quick and effective method of optimising operating conditions for the chosen phase system-hexane-ethyl acetate-methanol-water (1:0.8:1:0.6, v/v). Optimum conditions for resolution were a flow of 20 ml/min and speed of 1200 rpm, but for throughput were 80 ml/min at the same speed. The results show that 80 ml/min gave the best throughputs for tephrosin (518 mg/h), pyranoisoflavone (47.2 mg/h) and dehydrodeguelin (10.4 mg/h), whereas for deguelin (100.5 mg/h), the best flow rate was 40 ml/min.

  7. Evaluation of a new 3-dimensional color Doppler flow method to quantify flow across the mitral valve and in the left ventricular outflow tract: an in vitro study.

    PubMed

    Kimura, Sumito; Streiff, Cole; Zhu, Meihua; Shimada, Eriko; Datta, Saurabh; Ashraf, Muhammad; Sahn, David J

    2014-02-01

    The aim of this study was to assess the accuracy, feasibility, and reproducibility of determining stroke volume from a novel 3-dimensional (3D) color Doppler flow quantification method for mitral valve (MV) inflow and left ventricular outflow tract (LVOT) outflow at different stroke volumes when compared with the actual flow rate in a pumped porcine cardiac model. Thirteen freshly harvested pig hearts were studied in a water tank. We inserted a latex balloon into each left ventricle from the MV annulus to the LVOT, which were passively pumped at different stroke volumes (30-80 mL) using a calibrated piston pump at increments of 10 mL. Four-dimensional flow volumes were obtained without electrocardiographic gating. The digital imaging data were analyzed offline using prototype software. Two hemispheric flow-sampling planes for color Doppler velocity measurements were placed at the MV annulus and LVOT. The software computed the flow volumes at the MV annulus and LVOT within the user-defined volume and cardiac cycle. This novel 3D Doppler flow quantification method detected incremental increases in MV inflow and LVOT outflow in close agreement with pumped stroke volumes (MV inflow, r = 0.96; LVOT outflow, r = 0.96; P < .01). Bland-Altman analysis demonstrated overestimation of both (MV inflow, 5.42 mL; LVOT outflow, 4.46 mL) with 95% of points within 95% limits of agreement. Interobserver variability values showed good agreement for all stroke volumes at both the MV annulus and LVOT. This study has shown that the 3D color Doppler flow quantification method we used is able to compute stroke volumes accurately at the MV annulus and LVOT in the same cardiac cycle without electrocardiographic gating. This method may be valuable for assessment of cardiac output in clinical studies.

  8. Flexible mini gamma camera reconstructions of extended sources using step and shoot and list mode.

    PubMed

    Gardiazabal, José; Matthies, Philipp; Vogel, Jakob; Frisch, Benjamin; Navab, Nassir; Ziegler, Sibylle; Lasser, Tobias

    2016-12-01

    Hand- and robot-guided mini gamma cameras have been introduced for the acquisition of single-photon emission computed tomography (SPECT) images. Less cumbersome than whole-body scanners, they allow for a fast acquisition of the radioactivity distribution, for example, to differentiate cancerous from hormonally hyperactive lesions inside the thyroid. This work compares acquisition protocols and reconstruction algorithms in an attempt to identify the most suitable approach for fast acquisition and efficient image reconstruction, suitable for localization of extended sources, such as lesions inside the thyroid. Our setup consists of a mini gamma camera with precise tracking information provided by a robotic arm, which also provides reproducible positioning for our experiments. Based on a realistic phantom of the thyroid including hot and cold nodules as well as background radioactivity, the authors compare "step and shoot" (SAS) and continuous data (CD) acquisition protocols in combination with two different statistical reconstruction methods: maximum-likelihood expectation-maximization (ML-EM) for time-integrated count values and list-mode expectation-maximization (LM-EM) for individually detected gamma rays. In addition, the authors simulate lower uptake values by statistically subsampling the experimental data in order to study the behavior of their approach without changing other aspects of the acquired data. All compared methods yield suitable results, resolving the hot nodules and the cold nodule from the background. However, the CD acquisition is twice as fast as the SAS acquisition, while yielding better coverage of the thyroid phantom, resulting in qualitatively more accurate reconstructions of the isthmus between the lobes. For CD acquisitions, the LM-EM reconstruction method is preferable, as it yields comparable image quality to ML-EM at significantly higher speeds, on average by an order of magnitude. This work identifies CD acquisition protocols combined with LM-EM reconstruction as a prime candidate for the wider introduction of SPECT imaging with flexible mini gamma cameras in the clinical practice.

  9. Real-time quantitative PCR for retrovirus-like particle quantification in CHO cell culture.

    PubMed

    de Wit, C; Fautz, C; Xu, Y

    2000-09-01

    Chinese hamster ovary (CHO) cells have been widely used to manufacture recombinant proteins intended for human therapeutic uses. Retrovirus-like particles, which are apparently defective and non-infectious, have been detected in all CHO cells by electron microscopy (EM). To assure viral safety of CHO cell-derived biologicals, quantification of retrovirus-like particles in production cell culture and demonstration of sufficient elimination of such retrovirus-like particles by the down-stream purification process are required for product market registration worldwide. EM, with a detection limit of 1x10(6) particles/ml, is the standard retrovirus-like particle quantification method. The whole process, which requires a large amount of sample (3-6 litres), is labour intensive, time consuming, expensive, and subject to significant assay variability. In this paper, a novel real-time quantitative PCR assay (TaqMan assay) has been developed for the quantification of retrovirus-like particles. Each retrovirus particle contains two copies of the viral genomic particle RNA (pRNA) molecule. Therefore, quantification of retrovirus particles can be achieved by quantifying the pRNA copy number, i.e. every two copies of retroviral pRNA is equivalent to one retrovirus-like particle. The TaqMan assay takes advantage of the 5'-->3' exonuclease activity of Taq DNA polymerase and utilizes the PRISM 7700 Sequence Detection System of PE Applied Biosystems (Foster City, CA, U.S.A.) for automated pRNA quantification through a dual-labelled fluorogenic probe. The TaqMan quantification technique is highly comparable to the EM analysis. In addition, it offers significant advantages over the EM analysis, such as a higher sensitivity of less than 600 particles/ml, greater accuracy and reliability, higher sample throughput, more flexibility and lower cost. Therefore, the TaqMan assay should be used as a substitute for EM analysis for retrovirus-like particle quantification in CHO cell-based production system. Copyright 2000 The International Association for Biologicals.

  10. Low numbers of CD8+ T lymphocytes in hereditary haemochromatosis are explained by a decrease of the most mature CD8+ effector memory T cells.

    PubMed

    Macedo, M F; Porto, G; Costa, M; Vieira, C P; Rocha, B; Cruz, E

    2010-03-01

    Low CD8(+) T lymphocyte numbers have long been described in hereditary haemochromatosis (HH). Recently, two conserved haplotypes localized near the microsatellite D6S105 at the major histocompatibility complex (MHC) class I region were described predicting the clinical expression of HH and the CD8(+) T lymphocyte numbers. The A-A-T haplotype was associated with a severe clinical expression of HH and low CD8(+) T lymphocyte numbers, while the G-G-G haplotype was associated with a milder clinical expression of HH and high CD8(+) T lymphocyte numbers. As CD8(+) T lymphocytes are a very heterogeneous population, in this study we analysed the CD8(+) subpopulations of naive, central memory (T(CM)) and effector memory (T(EM)), and further subsets of CD8(+) T(EM) cells in 47 HH patients and 68 controls. In addition, association studies were conducted between the conserved haplotypes and the CD8(+) T cell subpopulations in HH. Variations of the numbers of naive and central memory cells with age were similar between HH patients and controls. For T(EM) cells and the T(EM) CD27(-)CD28(-) subset no effect of age was observed in HH [R(2) = 0.001, not significant (n.s.) and R(2) = 0.01, n.s., respectively] contrasting with the increasing of these subpopulations with age in controls (R(2) = 0.09, P = 0.017 and R(2) = 0.22, P = 0.0005, respectively). Interestingly, patients homozygous for the A-A-T haplotype have lower numbers of CD8(+) T(EM) cells due especially to lower numbers of T(EM) CD27(-)CD28(-) (0.206 +/- 0.119 and 0.066 +/- 0.067 x 10(6) cells/ml, respectively) than patients carrying the G-G-G haplotype (0.358 +/- 0.195 and 0.246 +/- 0.202 x 10(6) cells/ml, respectively). This may suggest an inability of HH patients to differentiate the CD8(+) T cells into the most mature phenotype.

  11. ART-ML: a new markup language for modelling and representation of biological processes in cardiovascular diseases.

    PubMed

    Karvounis, E C; Exarchos, T P; Fotiou, E; Sakellarios, A I; Iliopoulou, D; Koutsouris, D; Fotiadis, D I

    2013-01-01

    With an ever increasing number of biological models available on the internet, a standardized modelling framework is required to allow information to be accessed and visualized. In this paper we propose a novel Extensible Markup Language (XML) based format called ART-ML that aims at supporting the interoperability and the reuse of models of geometry, blood flow, plaque progression and stent modelling, exported by any cardiovascular disease modelling software. ART-ML has been developed and tested using ARTool. ARTool is a platform for the automatic processing of various image modalities of coronary and carotid arteries. The images and their content are fused to develop morphological models of the arteries in 3D representations. All the above described procedures integrate disparate data formats, protocols and tools. ART-ML proposes a representation way, expanding ARTool, for interpretability of the individual resources, creating a standard unified model for the description of data and, consequently, a format for their exchange and representation that is machine independent. More specifically, ARTool platform incorporates efficient algorithms which are able to perform blood flow simulations and atherosclerotic plaque evolution modelling. Integration of data layers between different modules within ARTool are based upon the interchange of information included in the ART-ML model repository. ART-ML provides a markup representation that enables the representation and management of embedded models within the cardiovascular disease modelling platform, the storage and interchange of well-defined information. The corresponding ART-ML model incorporates all relevant information regarding geometry, blood flow, plaque progression and stent modelling procedures. All created models are stored in a model repository database which is accessible to the research community using efficient web interfaces, enabling the interoperability of any cardiovascular disease modelling software models. ART-ML can be used as a reference ML model in multiscale simulations of plaque formation and progression, incorporating all scales of the biological processes.

  12. Geophysical Assessment of the Control of a Jetty on a Barrier Beach and Estuary System

    NASA Astrophysics Data System (ADS)

    Ulrich, C.; Hubbard, S. S.; Peterson, J.; Blom, K.; Black, W.; Delaney, C.; Mendoza, J.

    2014-12-01

    An evaluation is underway at the Goat Rock State Park, located at the mouth of the Russian River near Jenner, CA, to quantify the influence of a man made jetty on the functioning of a barrier beach and associated implications for estuary fish habitat and flood control. Flow through the beach results from water level differences between the estuary and the ocean. When the estuary is closed or perched, one of the major sources of outflow from the lagoon is seepage flow through the barrier beach. The location and design of the jetty could be altering subsurface flow paths through the jetty and possibly impeding subsurface flow where the jetty is still intact. This will result in unnatural connectivity between the ocean and the estuary leading to atypical surface water elevations and possibly salinity imbalance. We are monitoring seepage through the jetty and beach berm with multiple surface and borehole geophysical methods, including: electrical resistivity (ERT), seismic refraction (SR), ground penetrating radar (GPR), and electromagnetic methods (EM). We use SR data to characterize deeper bedrock controls on beach barrier functioning; ERT and EM methods to characterize the beach sediment layers that could contribute to preferential flow paths during tide cycles in addition to preferential flow paths created by the jetty structure; time-lapse ERT and EM data to monitor moisture changes and mixing of saline and fresh water within the beach berm, and borehole ERT and GPR data to delineate the geometry of the (often buried) jetty. Preliminary ERT and EM results indicate two preferential flow paths through zones of missing jetty structure, while time-lapse borehole ERT data is expected to image saltwater flow impedance in zones of intact jetty structure. All data are being integrated with topography, tidal, borehole, and hydrological information and the results of the assessment will enable the Sonoma County Water Agency to develop the feasibility of alternatives to the existing jetty that may help achieve target estuarine water surface elevations.

  13. Drag-reducing polymers diminish near-wall concentration of platelets in microchannel blood flow

    PubMed Central

    Zhao, R.; Marhefka, J.N.; Antaki, J.F.; Kameneva, M.V.

    2011-01-01

    The accumulation of platelets near the blood vessel wall or artificial surface is an important factor in the cascade of events responsible for coagulation and/or thrombosis. In small blood vessels and flow channels this phenomenon has been attributed to the blood phase separation that creates a red blood cell (RBC)-poor layer near the wall. We hypothesized that blood soluble drag-reducing polymers (DRP), which were previously shown to lessen the near-wall RBC depletion layer in small channels, may consequently reduce the near-wall platelet excess. This study investigated the effects of DRP on the lateral distribution of platelet-sized fluorescent particles (diam. = 2 µm, 2.5 × 108/ml) in a glass square microchannel (width and depth = 100 µm). RBC suspensions in PBS were mixed with particles and driven through the microchannel at flow rates of 6–18 ml/h with and without added DRP (10 ppm of PEO, MW = 4500 kDa). Microscopic flow visualization revealed an elevated concentration of particles in the near-wall region for the control samples at all tested flow rates (between 2.4 ± 0.8 times at 6 ml/h and 3.3 ± 0.3 times at 18 ml/h). The addition of a minute concentration of DRP virtually eliminated the near-wall particle excess, effectively resulting in their even distribution across the channel, suggesting a potentially significant role of DRP in managing and mitigating thrombosis. PMID:21084744

  14. Impact of laminar flow velocity of different acids on enamel calcium loss.

    PubMed

    Attin, T; Becker, K; Wiegand, A; Tauböck, T T; Wegehaupt, F J

    2013-03-01

    The aim of the study was to evaluate the impact of flow velocity under laminar flow conditions of different acidic solutions on enamel erosion. A total of 240 bovine enamel specimens were prepared and allocated to 30 groups (n = 8 each). Samples of 18 groups were superfused in a flow chamber system with laminar flow behavior using 1 ml of citric acid or hydrochloric acid (HCl) of pH 2.0, 2.6 or 3.0. Flow rates in the sample chamber were adjusted to 10, 60 or 100 μl/min. To simulate turbulent flow behavior, samples of six groups were immersed in 1 ml of the respective solution, which was vortexed (15 min, 600 rpm). For simulating non-agitated conditions, specimens of the remaining six groups were immersed in 1 ml of the respective solution without stirring. Calcium in the solutions, released from the enamel samples, was determined using Arsenazo III method. For acidic solutions of pH 2.6 and 3.0, erosive potential of citric acid was equivalent to that of HCl at a flow of 100 μl/min. The same observation was made for the samples subjected to turbulent conditions at pH 3. At all other conditions, citric acid induced a significantly higher calcium loss than HCl. It is concluded that under slow laminar flow conditions, flow rate variations lead to higher erosive impact of citric acid compared to hydrochloric acid at pH 2.0, but not at pH ≥ 2.6 and increasing laminar flow or turbulent conditions. Erosive enamel dissolution under laminar flow conditions is a complex issue influenced by flow rate and acidic substrate.

  15. Cardiac-gated, phase contrast magnetic resonance angiography is a reliable and reproducible technique for quantifying blood flow in canine major cranial abdominal vessels.

    PubMed

    Del Chicca, Francesca; Schwarz, Andrea; Grest, Paula; Willmitzer, Florian; Dennler, Matthias; Kircher, Patrick R

    2018-04-17

    Blood flow changes in cranial abdominal vessels are important contributing factors for canine hepatic disease. This prospective, experimental, pilot study aimed to evaluate cardiac-gated, phase contrast magnetic resonance angiography (PCMRA) as a method for characterizing blood flow in canine major cranial abdominal vessels. Eleven, healthy, adult beagle dogs were sampled. Cardiac-gated, phase contrast magnetic resonance angiography of the cranial abdomen was performed in each dog and blood flow was independently measured in each of the major cranial abdominal vessels by three observers, with two observers recording blood flow values once and one observer recording blood flow values three times. Each dog then underwent ultrasonographic examination of the liver with fine needle aspirations and biopsies submitted to cytologic and histologic examination. The mean absolute stroke volume and velocity were respectively 9.6 ± 1.9 ml and -11.1 ± 1.1 cm/s for the cranial abdominal aorta, 2.1 ± 0.6 ml and -6.6 ± 1.9 cm/s for the celiac artery, and 2.3 ± 1.0 ml and -7.9 ± 3.1 cm/s for the cranial mesenteric artery. The mean absolute stroke volume and velocity were respectively 6.7 ± 1.3 ml and 3.9 ± 0.9 cm/s for the caudal vena cava and 2.6 ± 0.9 ml and 3.2 ± 1.2 cm/s for the portal vein. Intraobserver reliability was excellent (intraclass correlation coefficient > 0.9). Interobserver reproducibility was also excellent (intraclass correlation coefficient 0.89-0.99). Results of liver ultrasonography, cytology, and histopathology were unremarkable. Findings indicated that cardiac-gated, phase contrast magnetic resonance angiography is a feasible technique for quantifying blood blow in canine major cranial abdominal vessels. Blood flow values from this sample of healthy beagles can be used as background for future studies on canine hepatic disease. © 2018 American College of Veterinary Radiology.

  16. Integrative literature review of the reported uses of serological tests in leprosy management.

    PubMed

    Fabri, Angélica da Conceição Oliveira Coelho; Carvalho, Ana Paula Mendes; Vieira, Nayara Figueiredo; Bueno, Isabela de Caux; Rodrigues, Rayssa Nogueira; Monteiro, Thayenne Barrozo Mota; Correa-Oliveira, Rodrigo; Duthie, Malcolm S; Lana, Francisco Carlos Félix

    2016-04-01

    An integrative literature review was conducted to synthesize available publications regarding the potential use of serological tests in leprosy programs. We searched the databases Literatura Latino-Americana e do Caribe em Ciências da Saúde, Índice Bibliográfico Espanhol em Ciências da Saúde, Acervo da Biblioteca da Organização Pan-Americana da Saúde, Medical Literature Analysis and Retrieval System Online, Hanseníase, National Library of Medicine, Scopus, Ovid, Cinahl, and Web of Science for articles investigating the use of serological tests for antibodies against phenolic glycolipid-I (PGL-I), ML0405, ML2331, leprosy IDRI diagnostic-1 (LID-1), and natural disaccharide octyl-leprosy IDRI diagnostic-1 (NDO-LID). From an initial pool of 3.514 articles, 40 full-length articles fulfilled our inclusion criteria. Based on these papers, we concluded that these antibodies can be used to assist in diagnosing leprosy, detecting neuritis, monitoring therapeutic efficacy, and monitoring household contacts or at-risk populations in leprosy-endemic areas. Thus, available data suggest that serological tests could contribute substantially to leprosy management.

  17. Architecting the Human Space Flight Program with Systems Modeling Language (SysML)

    NASA Technical Reports Server (NTRS)

    Jackson, Maddalena M.; Fernandez, Michela Munoz; McVittie, Thomas I.; Sindiy, Oleg V.

    2012-01-01

    The next generation of missions in NASA's Human Space Flight program focuses on the development and deployment of highly complex systems (e.g., Orion Multi-Purpose Crew Vehicle, Space Launch System, 21st Century Ground System) that will enable astronauts to venture beyond low Earth orbit and explore the moon, near-Earth asteroids, and beyond. Architecting these highly complex system-of-systems requires formal systems engineering techniques for managing the evolution of the technical features in the information exchange domain (e.g., data exchanges, communication networks, ground software) and also, formal correlation of the technical architecture to stakeholders' programmatic concerns (e.g., budget, schedule, risk) and design development (e.g., assumptions, constraints, trades, tracking of unknowns). This paper will describe how the authors have applied System Modeling Language (SysML) to implement model-based systems engineering for managing the description of the End-to-End Information System (EEIS) architecture and associated development activities and ultimately enables stakeholders to understand, reason, and answer questions about the EEIS under design for proposed lunar Exploration Missions 1 and 2 (EM-1 and EM-2).

  18. An Analysis on the Constitutive Models for Forging of Ti6Al4V Alloy Considering the Softening Behavior

    NASA Astrophysics Data System (ADS)

    Souza, Paul M.; Beladi, Hossein; Singh, Rajkumar P.; Hodgson, Peter D.; Rolfe, Bernard

    2018-05-01

    This paper developed high-temperature deformation constitutive models for a Ti6Al4V alloy using an empirical-based Arrhenius equation and an enhanced version of the authors' physical-based EM + Avrami equations. The initial microstructure was a partially equiaxed α + β grain structure. A wide range of experimental data was obtained from hot compression of the Ti6Al4 V alloy at deformation temperatures ranging from 720 to 970 °C, and at strain rates varying from 0.01 to 10 s-1. The friction- and adiabatic-corrected flow curves were used to identify the parameter values of the constitutive models. Both models provided good overall accuracy of the flow stress. The generalized modified Arrhenius model was better at predicting the flow stress at lower strain rates. However, the model was inaccurate in predicting the peak strain. In contrast, the enhanced physical-based EM + Avrami model revealed very good accuracy at intermediate and high strain rates, but it was also better at predicting the peak strain. Blind sample tests revealed that the EM + Avrami maintained good predictions on new (unseen) data. Thus, the enhanced EM + Avrami model may be preferred over the Arrhenius model to predict the flow behavior of Ti6Al4V alloy during industrial forgings, when the initial microstructure is partially equiaxed.

  19. Two techniques for eliminating luminol interference material and flow system configurations for luminol and firefly luciferase systems

    NASA Technical Reports Server (NTRS)

    Thomas, R. R.

    1976-01-01

    Two methods for eliminating luminol interference materials are described. One method eliminates interference from organic material by pre-reacting a sample with dilute hydrogen peroxide. The reaction rate resolution method for eliminating inorganic forms of interference is also described. The combination of the two methods makes the luminol system more specific for bacteria. Flow system designs for both the firefly luciferase and luminol bacteria detection systems are described. The firefly luciferase flow system incorporating nitric acid extraction and optimal dilutions has a functional sensitivity of 3 x 100,000 E. coli/ml. The luminol flow system incorporates the hydrogen peroxide pretreatment and the reaction rate resolution techniques for eliminating interference. The functional sensitivity of the luminol flow system is 1 x 10,000 E. coli/ml.

  20. [Effects of simulated body fluid flowing rate on bone-like apatite formation on porous calcium phosphate ceramics].

    PubMed

    Duan, You-rong; Liu, Ke-wei; Chen, Ji-yong; Zhang, Xing-dong

    2002-06-01

    Objective. Bone-like apatite formation on the surface of calcium phosphate ceramics was believed to be the necessary step that new bone grows on the ceramics and to be relative to the osteoinductivity of the material. This study aimed at investigating the influence of the flow rate of simulated body fluid (SBF) (2 ml/min) in skeletal muscle upon the formation of bone-like apatite on porous calcium phosphate ceramics. Method. The dynamic condition was realized by controlling the SBF flowing in/out of the sample chamber of 100 ml. The flow rate of 2 ml/min is close to that in human muscle environment. The pH and inorganic ionic composition of SBF are close to those of human body fluid. Result. Bone-like apatite formation was relatively easier to occur in static SBF than in dynamic SBF. Experiment with flowing SBF (dynamic SBF) is better in mimicking the living body fluid than static SBF. Conclusion. The results from dynamic SBF may more truly show the relation between apatite layer formation and osteoinduction in biomaterials than that from in vitro experiments before.

  1. Salivary flow rate and periodontal infection - a study among subjects aged 75 years or older.

    PubMed

    Syrjälä, A-M H; Raatikainen, L; Komulainen, K; Knuuttila, M; Ruoppi, P; Hartikainen, S; Sulkava, R; Ylöstalo, P

    2011-05-01

    To analyse the relation of stimulated and unstimulated salivary flow rates to periodontal infection in home-dwelling elderly people aged 75 years or older. This study was based on a subpopulation of 157 (111 women, 46 men) home-dwelling, dentate, non-smoking elderly people (mean age 79.8, SD 3.6 years) from the Geriatric Multidisciplinary Strategy for the Good Care of the Elderly Study). The data were collected by interview and oral clinical examination. Persons with very low (< 0.7 ml min⁻¹) and low stimulated salivary flow rates (0.7- < 1.0 ml min⁻¹) had a decreased likelihood of having teeth with deepened (≥ 4 mm) periodontal pockets, RR: 0.7, CI: 0.5-0.9 and RR: 0.7, CI: 0.5-0.9, respectively, when compared with those with normal stimulated salivary flow. Persons with a very low unstimulated salivary flow rate (< 0.1 ml min⁻¹) had a decreased likelihood of having teeth with deepened (≥ 4 mm) periodontal pockets, RR 0.8, CI: 0.6-1.0, when compared with subjects with low/normal unstimulated salivary flow. In a population of dentate, home-dwelling non-smokers, aged 75 years or older, low stimulated and unstimulated salivary flow rates were weakly associated with a decreased likelihood of having teeth with deep periodontal pockets. © 2010 John Wiley & Sons A/S.

  2. Free uroflowmetry versus "Do-It-Yourself" uroflowmetry in the assessment of patients with lower urinary tract symptoms.

    PubMed

    Mombelli, Gabriella; Picozzi, Stefano; Messina, Giovanni; Truffelli, Dario; Marenghi, Carlo; Maffi, Gabriele; Carmignani, Luca

    2014-10-01

    We investigated the possibility that patients could carry out a urine flow assessment at home by themselves, in comfort, without expense and without the use of equipment. We compared this strategy of "Do-It-Yourself" (DIY) uroflowmetry with traditional, hospital uroflowmetry. One hundred and twenty patients were enrolled. The patients underwent conventional, free uroflowmetry in hospital. Subsequently, the patients were asked to carry out the following procedure at home: urinate into a graduated container to quantify the total voided volume and determine the flow time by measuring the duration of miction with a stopwatch or simply with the second hand of a clock. This procedure had to be performed three times without preparation. Hundred patients completed the study. The mean age of the patients analysed was 64.12 years. Their free uroflowmetry values were as follows: the mean voiding time was 44.28 s, the mean voided volume was 290.92 ml, the mean Qmax was 15.17 ml/s, the mean Qmean was 7.87 ml/s, and the mean post-void residual volume was 78.44 ml. The mean Qmean measured by the "DIY-uroflowmetry" was 8.33 ml/s, which was not statistically significantly different (P = 0.12). Assuming that pathological hospital uroflowmetry values are equivalent to a DIY-Qmean ≤10 ml/s and that normal hospital values are equivalent to a DIY-Qmean >10 ml/s, the concordance was 100 %. Our proposed DIY evaluation of urine flow, together with the International Prostatic Symptom Score (IPSS), provides a good estimate of the results of free uroflowmetry, enabling unnecessary hospital investigations to be avoided.

  3. Skin blood flow response in the rat model of wound healing: expression of vasoactive factors.

    PubMed

    Rendell, Marc S; Johnson, Mark L; Smith, Denae; Finney, David; Capp, Christopher; Lammers, Rebecca; Lancaster, Scott

    2002-09-01

    Although the microvascular blood flow response to wounding is predominantly vasodilation at skin sites with nutritive capillary perfusion (NUTR), there is a significant vasoconstrictive response at sites with high arteriovenous perfusion (AV). There may be a difference between NUTR and AV sites in the vasoactive factors which mediate the blood flow response to wounding. We measured the levels of mRNA expression of several potential mediators of the blood flow response to assess this possible difference. We measured skin blood flow at wounds placed at the back, a NUTR site, and at the paw, an AV site, in 12 Wistar Kyoto rats. Measurements were performed at baseline and then at 7 days post wounding. There was a significant increase in blood flow at back wound sites, with a rise from 4.1 +/- 0.3 ml/min/100 g to 9.8 +/- 1.9 ml/min/100 g. At the undisturbed wound perimeter, outside the zone of granulation tissue, flow rose to 7.3 +/- 1.1 ml/min/100 g. At the paw wound site, Day 0 flow was 8.8 +/- 0.8 ml/min/100 g. At 7 days, there was a significant decrease in flow at wound center to 5.5 +/- 0.5 ml/min/100 g. We measured the levels of inducible nitric oxide synthetase (iNOS), endothelin, endothelin receptor, vascular endothelial growth factor (VEGF), and keratinocyte growth factor (KGF) gene mRNAs using reverse transcriptase PCR. There was a 10-fold increase in NOS mRNA in granulation tissue of both wounds on Day 7. There was a lesser but still substantial increase in the wound perimeter tissue. Levels of endothelin mRNA in the wound and wound perimeter were significantly lower at the paw than at the back. At baseline, the level of endothelin receptor B (ETrB) mRNA was greater at the back than at the paw. Wounding resulted in a substantial increase in EtrB mRNA levels in granulation tissue, reaching the same level at the back and paw wounds. There was also a substantial rise in EtrB mRNA levels at the paw wound perimeter, so that there was a reversal of the baseline condition, with paw levels actually surpassing the levels at the back perimeter. Thus, we have found significant changes in mediators both of vasoconstriction and vasodilation affecting the healing wound. These changes affect NUTR and AV sites in different ways. These results demonstrate the complexity of the regulatory processes controlling microvascular blood flow in wound healing.

  4. United States Air Force Summer Research Program - 1991. Summer Faculty Research Program (SFRP) Reports. Volume 2. Armstrong Laboratory, Wilford Hall Medical Center

    DTIC Science & Technology

    1991-12-01

    results were to be generated in a form suitable for use in the Physiologically Based Pharmacokinetic Models. The literature was searched from 1979 to...body Blood flow % Cardiac 02 consumption wt(kg) weight (ml/min) output (ml/min/organ) Brain 1.4 2.0 775 15 46 Heart 0.3 0.43 175 3.3 23 Kidneys 0.3 0.43...Plasma Flow 500-800 ml/min(calculated per 24 hours) Volume, Blood 49-75m1\\kg body wt.Male 56-75m1/kg body wt.Female 2 500-400m1 /m2 Plasma 31-55m1/kg

  5. In vitro performance of the fixed and adjustable gravity-assisted unit with and without motion-evidence of motion-induced flow.

    PubMed

    Kimura, Takaoki; Schulz, Matthias; Shimoji, Kazuaki; Miyajima, Masakazu; Arai, Hajime; Thomale, Ulrich-Wilhelm

    2016-10-01

    Anti-siphon devices and gravitational-assisted valves have been introduced to counteract the effects of overdrainage after implantation of a shunt system. The study examined the flow performance of two gravitational-assisted valves (shunt assistant - SA and programmable shunt assistant - proSA, Miethke & Co. KG, Potsdam, Germany) in an in vitro shunt laboratory with and without motion. An in vitro laboratory setup was used to model the cerebrospinal fluid (CSF) drainage conditions similar to a ventriculo-peritoneal shunt and to test the SA (resistance of +20 cmH2O in 90°) and proSA (adjustable resistance of 0 to +40 cmH2O in 90°). The differential pressure (DP) through the simulated shunt and tested valve was adjusted between 0 and 60 cmH2O by combinations of different inflow pressures (40, 30, 20, 10, and 0 cmH2O) and the hydrostatic negative outflow pressure (0, -20, and -40 cmH2O) in several differing device positions (0°, 30°, 60°, and 90°). In addition, the two devices were tested under vertical motion with movement frequencies of 2, 3, and 4 Hz. Both gravity-assisted units effectively counteract the hydrostatic effect in relation to the chosen differential pressure. The setting the proSA resulted in flow reductions in the 90° position according to the chosen resistance of the device. Angulation-related flow changes were similar in the two devices in 30-90° position, however, in the 0-30° position, a higher flow is seen in the proSA. Repeated vertical movement significantly increased flow through both devices. While with the proSA a 2-Hz motion was not able to induce additional flow (0.006 ± 0.05 ml/min), 3- and 4-Hz motion significantly induced higher flow values (3 Hz: +0.56 ± 0.12 ml/min, 4 Hz: +0.54 ± 0.04 ml/min). The flow through the SA was not induced by vertical movements at a low DP of 10 cmH2O at all frequencies, but at DPs of 30 cmH2O and higher, all frequencies significantly induced higher flow values (2 Hz: +0.36 ± 0.14 ml/min, 3 Hz: +0.32 ± 0.08 ml/min, 4 Hz: +0.28 ± 0.09 ml/min). In a static setup, both tested valves effectively counteracted the hydrostatic effect according to their adjusted or predefined resistance in vertical position. Motion-induced increased flow was demonstrated for both devices with different patterns of flow depending on applied DP and setting of the respective valve. The documented increased drainage should be considered when selecting appropriate valves and settings in very active patients.

  6. An advanced expiratory circuit for the recovery of perfluorocarbon liquid from non-saturated perfluorocarbon vapour during partial liquid ventilation: an experimental model

    PubMed Central

    Dunster, Kimble R; Davies, Mark W; Fraser, John F

    2006-01-01

    Background The loss of perfluorocarbon (PFC) vapour in the expired gases during partial liquid ventilation should be minimized both to prevent perfluorocarbon vapour entering the atmosphere and to re-use the recovered PFC liquid. Using a substantially modified design of our previously described condenser, we aimed to determine how much perfluorocarbon liquid could be recovered from gases containing PFC and water vapour, at concentrations found during partial liquid ventilation, and to determine if the amount recovered differed with background flow rate (at flow rates suitable for use in neonates). Methods The expiratory line of a standard ventilator circuit set-up was mimicked, with the addition of two condensers. Perfluorocarbon (30 mL of FC-77) and water vapour, at concentrations found during partial liquid ventilation, were passed through the circuit at a number of flow rates and the percentage recovery of the liquids measured. Results From 14.2 mL (47%) to 27.3 mL (91%) of the infused 30 mL of FC-77 was recovered at the flow rates studied. Significantly higher FC-77 recovery was obtained at lower flow rates (ANOVA with Bonferroni's multiple comparison test, p < 0.0001). As a percentage of the theoretical maximum recovery, 64 to 95% of the FC-77 was recovered. Statistically significantly less FC-77 was recovered at 5 Lmin-1 (ANOVA with Bonferroni's multiple comparison test, p < 0.0001). Amounts of perfluorocarbon vapour recovered were 47%, 50%, 81% and 91% at flow rates of 10, 5, 2 and 1 Lmin-1, respectively. Conclusion Using two condensers in series 47% to 91% of perfluorocarbon liquid can be recovered, from gases containing perfluorocarbon and water vapour, at concentrations found during partial liquid ventilation. PMID:16457722

  7. Sex differences with aging in nutritive skeletal muscle blood flow: impact of exercise training, nitric oxide, and α-adrenergic-mediated mechanisms

    PubMed Central

    La Favor, Justin D.; Kraus, Raymond M.; Carrithers, Jonathan A.; Roseno, Steven L.; Gavin, Timothy P.

    2014-01-01

    The incidence of cardiovascular disease increases progressively with age, but aging may affect men and women differently. Age-associated changes in vascular structure and function may manifest in impaired nutritive blood flow, although the regulation of nutritive blood flow in healthy aging is not well understood. The purpose of this study was to determine if nitric oxide (NO)-mediated or α-adrenergic-mediated regulation of nutritive skeletal muscle blood flow is impaired with advanced age, and if exercise training improves age-related deficiencies. Nutritive blood flow was monitored in the vastus lateralis of healthy young and aged men and women via the microdialysis-ethanol technique prior to and following seven consecutive days of exercise training. NO-mediated and α-adrenergic-mediated regulation of nutritive blood flow was assessed by microdialysis perfusion of acetylcholine, sodium nitroprusside, NG-monomethyl-l-arginine, norepinephrine, or phentolamine. Pretraining nutritive blood flow was attenuated in aged compared with young women (7.39 ± 1.5 vs. 15.5 ± 1.9 ml·100 g−1·min−1, P = 0.018), but not aged men (aged 13.5 ± 3.7 vs. young 9.4 ± 1.3 ml·100 g−1·min−1, P = 0.747). There were no age-associated differences in NO-mediated or α-adrenergic-mediated nutritive blood flow. Exercise training increased resting nutritive blood flow only in young men (9.4 ± 1.3 vs. 19.7 ml·100 g−1·min−1, P = 0.005). The vasodilatory effect of phentolamine was significantly reduced following exercise training only in young men (12.3 ± 6.14 vs. −3.68 ± 3.26 ml·100 g−1·min−1, P = 0.048). In conclusion, the age-associated attenuation of resting nutritive skeletal muscle blood flow was specific to women, while the exercise-induced alleviation of α-adrenergic mediated vasoconstriction that was specific to young men suggests an age-associated modulation of the sympathetic response to exercise training. PMID:24951753

  8. Sex differences with aging in nutritive skeletal muscle blood flow: impact of exercise training, nitric oxide, and α-adrenergic-mediated mechanisms.

    PubMed

    La Favor, Justin D; Kraus, Raymond M; Carrithers, Jonathan A; Roseno, Steven L; Gavin, Timothy P; Hickner, Robert C

    2014-08-15

    The incidence of cardiovascular disease increases progressively with age, but aging may affect men and women differently. Age-associated changes in vascular structure and function may manifest in impaired nutritive blood flow, although the regulation of nutritive blood flow in healthy aging is not well understood. The purpose of this study was to determine if nitric oxide (NO)-mediated or α-adrenergic-mediated regulation of nutritive skeletal muscle blood flow is impaired with advanced age, and if exercise training improves age-related deficiencies. Nutritive blood flow was monitored in the vastus lateralis of healthy young and aged men and women via the microdialysis-ethanol technique prior to and following seven consecutive days of exercise training. NO-mediated and α-adrenergic-mediated regulation of nutritive blood flow was assessed by microdialysis perfusion of acetylcholine, sodium nitroprusside, N(G)-monomethyl-L-arginine, norepinephrine, or phentolamine. Pretraining nutritive blood flow was attenuated in aged compared with young women (7.39 ± 1.5 vs. 15.5 ± 1.9 ml·100 g(−1)·min(−1), P = 0.018), but not aged men (aged 13.5 ± 3.7 vs. young 9.4 ± 1.3 ml·100 g(−1)·min(−1), P = 0.747). There were no age-associated differences in NO-mediated or α-adrenergic-mediated nutritive blood flow. Exercise training increased resting nutritive blood flow only in young men (9.4 ± 1.3 vs. 19.7 ml·100 g(−1)·min(−1), P = 0.005). The vasodilatory effect of phentolamine was significantly reduced following exercise training only in young men (12.3 ± 6.14 vs. −3.68 ± 3.26 ml·100 g(−1)·min(−1), P = 0.048). In conclusion, the age-associated attenuation of resting nutritive skeletal muscle blood flow was specific to women, while the exercise-induced alleviation of α-adrenergic mediated vasoconstriction that was specific to young men suggests an age-associated modulation of the sympathetic response to exercise training.

  9. Quantification of gastric emptying and duodenogastric reflux stroke volumes using three-dimensional guided digital color Doppler imaging.

    PubMed

    Hausken, T; Li, X N; Goldman, B; Leotta, D; Ødegaard, S; Martin, R W

    2001-07-01

    To develop a non-invasive method for evaluating gastric emptying and duodenogastric reflux stroke volumes using three-dimensional (3D) guided digital color Doppler imaging. The technique involved color Doppler digital images of transpyloric flow in which the 3D position and orientation of the images were known by using a magnetic location system. In vitro, the system was found to slightly underestimate the reference flow (by average 8.8%). In vivo (five volunteers), stroke volume of gastric emptying episodes lasted on average only 0.69 s with a volume on average of 4.3 ml (range 1.1-7.4 ml), and duodenogastric reflux episodes on average 1.4 s with a volume of 8.3 ml (range 1.3-14.1 ml). With the appropriate instrument settings, orientation determined color Doppler can be used for stroke volume quantification of gastric emptying and duodenogastric reflux episodes.

  10. Design and Development of a Segmented Magnet Homopolar Torque Converter

    DTIC Science & Technology

    1975-02-01

    seals . They will be designed for low leakage and wear at operating speeds from zero to 500 rpm in either direction. 1-7 — . E.M. 4648 SECTION 2...to flow in a manner that would minimize the pressure drop across the seals , thus minimizing leakage flow. As an example, the liquid metal might be...included seal wear, leakage and operating temperature leaicage. 6-2 J E.M. 4648 order to obtain bench mark performance data on standard seal

  11. Coronary oscillatory flow amplitude is more affected by perfusion pressure than ventricular pressure.

    PubMed

    Krams, R; Sipkema, P; Westerhof, N

    1990-06-01

    In this study on the isolated, maximally vasodilated, blood-perfused cat heart we investigated the relation between left ventricular developed pressure (delta Piv) and coronary oscillatory flow amplitude (diastolic minus systolic flow, delta F) at different levels of constant perfusion pressure (Pp). We hypothesized that the effect of cardiac contraction on the phasic flow results from the changing elastic properties of cardiac muscle. The coronary vessel compartment can, as can the left ventricular lumen compartment, be described by a time-varying elastance. This concept predicts that the effect of left ventricular pressure on delta F is small, whereas the effect of Pp is considerable. Both the waterfall model and the intramyocardial pump model predict the inverse. The relation between delta Piv and delta F at a Pp of 10 kPa is delta F = (4.71 +/- 3.08).delta Piv + 337 +/- 75 (slope in ml.min-1.100 g-1.kPa-1 and intercept in ml.min-1.100 g-1; n = 7); the relation between (constant levels of) Pp and delta F at a constant delta Piv of 10 kPa is delta F = 51.Pp + 211 (slope in ml.min-1.100 g-1.kPa-1 and intercept in ml.min-1.100 g-1; n = 6). The differences in slope are best predicted by the time-varying elastance concept.

  12. Fluorimetric determination of some thiol compounds in their dosage forms.

    PubMed

    Al-Ghannam, Sh M; El-Brashy, A M; Al-Farhan, B S

    2002-08-01

    A simple fluorimetric procedure was adopted for determination of three pharmaceutical compounds containing thiol groups namely, captopril, D-penicillamine and N-acetylcysteine. In this method, the drugs are treated with 1,2-naphthoquinone-4-sulfonic acid. The latter is reduced to 1,2-dihydroxynaphthalene-4-sulfonic acid which has a maximum fluorescence intensity at 480/318 nm (lambdaEm/Ex). The method is sensitive to 0.5-4.5 pg ml(- 1) with minimum detectability 0.05 microg ml(-1) (S/N = 2), and has been applied to determine these three thiols in their dosage forms. The results obtained are compared favourably with those obtained by their pharmacopeial methods.

  13. Selective induction of apoptosis in human gastric cancer cells by Lactobacillus kefiri (PFT), a novel kefir product

    PubMed Central

    GHONEUM, MAMDOOH; FELO, NOURAN

    2015-01-01

    The present study was undertaken to evaluate the effect of Lactobacillus kefiri (PFT), a novel kefir product, on apoptosis of gastric cancer cells (AGS), breast cancer cells (4T1), and human peripheral blood mononuclear cells (PBMCs). Cells were cultured with PFT and apoptosis was determined by flow cytometry using 7-AAD dye and cytospin preparation. Mitochondrial dysfunction and expression of Bcl2 were monitored by flow cytometry. Results showed that PFT induced apoptosis in AGS gastric cancer cells in a dose-dependent manner. Apoptosis was detected at a concentration of 0.3 mg/ml (20.8%), increased to 25.8% at 0.6 mg/ml, 37% at 1.2 mg/ml, 53.1% at 2.5 mg/ml, and peaked at 66.3% at 5.0 mg/ml. Apoptosis is associated with the decreased polarization of mitochondrial membrane potential (MMP) and decreased Bcl2 expression. PFT-treated AGS cells manifested membrane blebbing, nuclear condensation, and fragmentation as identified in cytospin cytocentrifuge Giemsa stained preparations. On the other hand, flow cytometry analysis showed that PFT did not induce apoptosis in 4T1 breast cancer cells nor in PBMCs. These results suggest that PFT is safe for white blood cells and selectively induces apoptotic effects in gastric cancer cells. Hence, it may have potential as a therapeutic agent for the treatment of gastric cancers. PMID:26251956

  14. CytometryML: a markup language for analytical cytology

    NASA Astrophysics Data System (ADS)

    Leif, Robert C.; Leif, Stephanie H.; Leif, Suzanne B.

    2003-06-01

    Cytometry Markup Language, CytometryML, is a proposed new analytical cytology data standard. CytometryML is a set of XML schemas for encoding both flow cytometry and digital microscopy text based data types. CytometryML schemas reference both DICOM (Digital Imaging and Communications in Medicine) codes and FCS keywords. These schemas provide representations for the keywords in FCS 3.0 and will soon include DICOM microscopic image data. Flow Cytometry Standard (FCS) list-mode has been mapped to the DICOM Waveform Information Object. A preliminary version of a list mode binary data type, which does not presently exist in DICOM, has been designed. This binary type is required to enhance the storage and transmission of flow cytometry and digital microscopy data. Index files based on Waveform indices will be used to rapidly locate the cells present in individual subsets. DICOM has the advantage of employing standard file types, TIF and JPEG, for Digital Microscopy. Using an XML schema based representation means that standard commercial software packages such as Excel and MathCad can be used to analyze, display, and store analytical cytometry data. Furthermore, by providing one standard for both DICOM data and analytical cytology data, it eliminates the need to create and maintain special purpose interfaces for analytical cytology data thereby integrating the data into the larger DICOM and other clinical communities. A draft version of CytometryML is available at www.newportinstruments.com.

  15. Selective induction of apoptosis in human gastric cancer cells by Lactobacillus kefiri (PFT), a novel kefir product.

    PubMed

    Ghoneum, Mamdooh; Felo, Nouran

    2015-10-01

    The present study was undertaken to evaluate the effect of Lactobacillus kefiri (PFT), a novel kefir product, on apoptosis of gastric cancer cells (AGS), breast cancer cells (4T1), and human peripheral blood mononuclear cells (PBMCs). Cells were cultured with PFT and apoptosis was determined by flow cytometry using 7-AAD dye and cytospin preparation. Mitochondrial dysfunction and expression of Bcl2 were monitored by flow cytometry. Results showed that PFT induced apoptosis in AGS gastric cancer cells in a dose-dependent manner. Apoptosis was detected at a concentration of 0.3 mg/ml (20.8%), increased to 25.8% at 0.6 mg/ml, 37% at 1.2 mg/ml, 53.1% at 2.5 mg/ml, and peaked at 66.3% at 5.0 mg/ml. Apoptosis is associated with the decreased polarization of mitochondrial membrane potential (MMP) and decreased Bcl2 expression. PFT-treated AGS cells manifested membrane blebbing, nuclear condensation, and fragmentation as identified in cytospin cytocentrifuge Giemsa stained preparations. On the other hand, flow cytometry analysis showed that PFT did not induce apoptosis in 4T1 breast cancer cells nor in PBMCs. These results suggest that PFT is safe for white blood cells and selectively induces apoptotic effects in gastric cancer cells. Hence, it may have potential as a therapeutic agent for the treatment of gastric cancers.

  16. Effects of intravenous lipopolysaccharide infusion on glucose and insulin dynamics in horses with equine metabolic syndrome.

    PubMed

    Tadros, Elizabeth M; Frank, Nicholas; De Witte, Fiamma Gomez; Boston, Raymond C

    2013-07-01

    To test the hypothesis that glucose and insulin dynamics during endotoxemia differ between healthy horses and horses with equine metabolic syndrome (EMS). 6 healthy adult mares and 6 horses with EMS. Each horse randomly received an IV infusion of lipopolysaccharide (20 ng/kg [in 60 mL of sterile saline {0.9% NaCl} solution]) or saline solution, followed by the other treatment after a 7-day washout period. Baseline insulin-modified frequently sampled IV glucose tolerance tests were performed 27 hours before and then repeated at 0.5 and 21 hours after infusion. Results were assessed via minimal model analysis and area under the curve values for plasma glucose and serum insulin concentrations. Lipopolysaccharide infusion decreased insulin sensitivity and increased area under the serum insulin concentration curve (treatment × time) in both healthy and EMS-affected horses, compared with findings following saline solution administration. The magnitude of increase in area under the plasma glucose curve following LPS administration was greater for the EMS-affected horses than it was for the healthy horses. Horses with EMS that received LPS or saline solution infusions had decreased insulin sensitivity over time. Glucose and insulin responses to endotoxemia differed between healthy horses and horses with EMS, with greater loss of glycemic control in EMS-affected horses. Horses with EMS also had greater derangements in glucose and insulin homeostasis that were potentially stress induced. It may therefore be helpful to avoid exposure of these horses to stressful situations.

  17. ACUTE EFFECT OF A SINGLE HIGH-FAT MEAL ON FOREARM BLOOD FLOW, BLOOD PRESSURE AND HEART RATE IN HEALTHY MALE ASIANS AND CAUSASIANS: A PILOT STUDY

    PubMed Central

    Bui, Chumjit; Petrofsky, Jerrold; Berk, Lee; Shavlik, David; Remigio, Wilton; Montgomery, Susanne

    2011-01-01

    Research has shown that ingestion of a single high-fat (HF) meal causes postprandial lipemia and produces a reduced brachial artery blood flow response to vascular occlusion in Caucasians. However, the forearm BF response to occlusion in Caucasian and Asian populations after a single HF meal has not been compared. Eleven healthy male Asians, mean age 26.4 (±4.2) years, height 174.2 (±7.4) cm, and weight 73.8 (±5.7) kg and eight Caucasians, mean age 26.8 (±4.6) years, height 182.9 (±5.9) cm, and weight 82.8 (±4.8) kg were studied. A randomized cross-over study design was used with a HF (50.1 g total fat) or low-fat (LF) (5.1 g total fat) test meal 1 week apart. Forearm blood flow was measured over a 2-minute period following a 4-minute occlusion (FBFO) at 2 and 4 hours following ingestion of a test meal. This study found that FBFO was significantly attenuated in Asians (19.3%; p=0.09) compared to Caucasians after the ingestion of a HF meal. When comparing LF vs HF meals in Asians, the FBFO were 336.9 ml/100 ml tissue/minute and 240.8 ml/100 ml tissue/minute, respectively (p=0.02), whereas in Caucasians, the FBFO were 344.8 ml/100 ml tissue/minute and 287.4 ml/100 ml tissue/minute, respectively. It appears Asians have a more sensitive response to a single HF meal which may be explained, in part, by genotypic variation. These findings suggest that a single HF meal may contribute to the detrimental effects on vascular health in Asian males and raises speculation regarding the cumulative impact of a chronic HF diet in this population. PMID:20578534

  18. Enantioselectivity of debrisoquine 4-hydroxylation in Brazilian Caucasian hypertensive patients phenotyped as extensive metabolizers.

    PubMed

    Cerqueira, P M; Mateus, F H; Cesarino, E J; Bonato, P S; Lanchote, V L

    2000-12-01

    Debrisoquine (D), an antihypertensive drug metabolized to 4-hydroxydebrisoquine (4-OHD) by CYP2D6, is commonly used as an in vivo probe of CYP2D6 activity and can be used to phenotype individuals as either extensive (EMs) or poor metabolizers (PMs) of such drugs as beta-adrenergic blockers, tricyclic antidepressants, and class 1C antiarrhythmics. This report describes reversed-phase HPLC systems by which D and 4-OHD or S-(+) and R-(-)-4-OHD in urine are more selectively quantified without the need for derivatization techniques. We also studied the urinary excretion of R-(-)- and S-(+)-4-hydroxydebrisoquine in EM hypertensive patients in order to determine weather 4-OHD formation exhibits enantioselectivity. Twelve patients with mild to severe essential hypertension were admitted to the study. They received a single tablet of Declinax containing 10 mg debrisoquine sulfate. All the urine excreted during the following 8 h was collected. The debrisoquine metabolic ratio (DMR) was calculated as % of dose excreted as D/% of dose excreted as 4-OHD and the debrisoquine recovery ratio (DRR) was calculated as % of dose excreted as 4-OHD/% of dose excreted as D+4-OHD. Debrisoquine and its metabolite were determined in urine by HPLC using a reversed-phase Select B LiChrospher column, a mobile phase of 0.25 N acetate buffer, pH 5-acetonitrile (9:1, v/v) and a fluorescence detector. The limit of quantitation was determined to be 25.0 ng/ml for D and 18.75 ng/ml for 4-OHD. Intra- and inter-day relative standard deviations (RSDs) were less than 10%. All hypertensive patients studied showed a DMR of less than 12.6 or a DRR higher than 0.12 and were classified as EMs. Direct enantioselective separation on chiral stationary phase involved resolution of S-(+)-4-OHD and R-(-)-4-OHD on a Chiralcel OD-R column with a mobile phase of 0.125 N sodium perchlorate, pH 5-acetonitrile-methanol (85:12:3, v/v/v). The quantitation limit of each enantiomer was 3.75 ng/ml of urine. Intra- and inter-day RSDs were less than 10% for each enantiomer. A high degree of enantioselectivity in the 4-hydroxylation of D favouring the S-(+) enantiomer was observed, resulting in R-(-)-4-OHD not detected in the urine of the EM hypertensive patients studied.

  19. Arterial supply, venous drainage and collateral circulation in the nose of the anaesthetized dog.

    PubMed Central

    Lung, M A; Wang, J C

    1987-01-01

    1. In pentobarbitone-anaesthetized dogs, nasal blood flows were measured with electromagnetic flow sensors. 2. The terminal internal maxillary artery was found to supply 22 +/- 2.2 ml min-1 (one side) to the nasal mucosa via the sphenopalatine and major palatine branches; the artery was found to receive multiple supply routes from common carotid, vertebral and subclavian arteries. 3. Nasal mucosa was found to receive collateral flow from contralateral terminal internal maxillary artery (about 5 to 10% of normal flow) and branches of subclavian arteries (about 36% of normal flow). 4. Nasal mucosa was found to have two venous systems: the low-flow (12 +/- 1.0 ml min-1; both sides) and low-pressure (7 +/- 0.6 mmHg) sphenopalatine veins draining the posterior nasal cavity and the high-flow (30 +/- 1.4 ml min-1; both sides) and high-pressure (17 +/- 1.0 mmHg) dorsal nasal veins draining the anterior nasal cavity. 5. PO2 of nasal venous blood was found to range from 62 +/- 2.9 mmHg to 65 +/- 3.4 mmHg. During nitrogen challenge to the nose, the sphenopalatine venous PO2 dropped to 35 +/- 3.0 mmHg while the dorsal nasal venous PO2 remained unchanged, suggesting that the sphenopalatine veins were responsible for draining capillary flow and dorsal nasal veins arteriovenous anastomotic flow as well. 6. Microscopic examination of the vascular casts confirmed that arteriovenous anastomoses were located only in the anterior nasal cavity. Images Fig. 5 Plate 1 Plate 2 PMID:3443958

  20. Applicability of multisyringe chromatography coupled to on-line solid-phase extraction to the simultaneous determination of dicamba, 2,4-D, and atrazine.

    PubMed

    Chávez-Moreno, C A; Guzmán-Mar, J L; Hinojosa-Reyes, L; Hernández-Ramírez, A; Ferrer, L; Cerdà, V

    2012-07-01

    Simultaneous determination of three herbicides (dicamba, 2,4-D, and atrazine) has been achieved by on-line solid-phase extraction (SPE) coupled to multisyringe chromatography (MSC) with UV detection. The preconcentration conditions were optimized; a preconcentration flow rate of 0.5 mL min(-1) and elution at 0.8 mL min(-1) were the optimum conditions. A C(18) (8 mm i.d.) membrane extraction disk conditioned with 0.3 mol L(-1) HCl in 0.5% MeOH was used. A 3-mL sample was preconcentrated, then eluted with 0.43 mL 40:60 water-MeOH. A C(18) monolithic column (25 mm × 4.6 mm) was used for chromatographic separation. Separation of the three compounds was achieved in 10 min by use of 0.01% aqueous acetic acid-MeOH (60:40) as mobile phase at a flow rate of 0.8 mL min(-1). The limits of detection (LOD) were 13, 57, and 22 μg L(-1) for dicamba, 2,4-D, and atrazine, respectively. The sampling frequency was three analyses per hour, and each analysis consumed only 7.3 mL solvent. The method was applied to spiked water samples, and recovery between 85 and 112% was obtained. Recovery was significantly better than in the conventional HPLC-UV method. These results indicated the reliability and accuracy of this flow-based method. This is the first time this family of herbicides has been simultaneously analyzed by on-line SPE-MSC using a monolithic column.

  1. Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility.

    PubMed

    Cutajar, Marica; Thomas, David L; Hales, Patrick W; Banks, T; Clark, Christopher A; Gordon, Isky

    2014-06-01

    To investigate the reproducibility of arterial spin labelling (ASL) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and quantitatively compare these techniques for the measurement of renal blood flow (RBF). Sixteen healthy volunteers were examined on two different occasions. ASL was performed using a multi-TI FAIR labelling scheme with a segmented 3D-GRASE imaging module. DCE MRI was performed using a 3D-FLASH pulse sequence. A Bland-Altman analysis was used to assess repeatability of each technique, and determine the degree of correspondence between the two methods. The overall mean cortical renal blood flow (RBF) of the ASL group was 263 ± 41 ml min(-1) [100 ml tissue](-1), and using DCE MRI was 287 ± 70 ml min(-1) [100 ml tissue](-1). The group coefficient of variation (CVg) was 18 % for ASL and 28 % for DCE-MRI. Repeatability studies showed that ASL was more reproducible than DCE with CVgs of 16 % and 25 % for ASL and DCE respectively. Bland-Altman analysis comparing the two techniques showed a good agreement. The repeated measures analysis shows that the ASL technique has better reproducibility than DCE-MRI. Difference analysis shows no significant difference between the RBF values of the two techniques. Reliable non-invasive monitoring of renal blood flow is currently clinically unavailable. Renal arterial spin labelling MRI is robust and repeatable. Renal dynamic contrast-enhanced MRI is robust and repeatable. ASL blood flow values are similar to those obtained using DCE-MRI.

  2. Effective regurgitant orifice area by the color Doppler flow convergence method for evaluating the severity of chronic aortic regurgitation. An animal study.

    PubMed

    Shiota, T; Jones, M; Yamada, I; Heinrich, R S; Ishii, M; Sinclair, B; Holcomb, S; Yoganathan, A P; Sahn, D J

    1996-02-01

    The aim of the present study was to evaluate dynamic changes in aortic regurgitant (AR) orifice area with the use of calibrated electromagnetic (EM) flowmeters and to validate a color Doppler flow convergence (FC) method for evaluating effective AR orifice area and regurgitant volume. In 6 sheep, 8 to 20 weeks after surgically induced AR, 22 hemodynamically different states were studied. Instantaneous regurgitant flow rates were obtained by aortic and pulmonary EM flowmeters balanced against each other. Instantaneous AR orifice areas were determined by dividing these actual AR flow rates by the corresponding continuous wave velocities (over 25 to 40 points during each diastole) matched for each steady state. Echo studies were performed to obtain maximal aliasing distances of the FC in a low range (0.20 to 0.32 m/s) and a high range (0.70 to 0.89 m/s) of aliasing velocities; the corresponding maximal AR flow rates were calculated using the hemispheric flow convergence assumption for the FC isovelocity surface. AR orifice areas were derived by dividing the maximal flow rates by the maximal continuous wave Doppler velocities. AR orifice sizes obtained with the use of EM flowmeters showed little change during diastole. Maximal and time-averaged AR orifice areas during diastole obtained by EM flowmeters ranged from 0.06 to 0.44 cm2 (mean, 0.24 +/- 0.11 cm2) and from 0.05 to 0.43 cm2 (mean, 0.21 +/- 0.06 cm2), respectively. Maximal AR orifice areas by FC using low aliasing velocities overestimated reference EM orifice areas; however, at high AV, FC predicted the reference areas more reliably (0.25 +/- 0.16 cm2, r = .82, difference = 0.04 +/- 0.07 cm2). The product of the maximal orifice area obtained by the FC method using high AV and the velocity time integral of the regurgitant orifice velocity showed good agreement with regurgitant volumes per beat (r = .81, difference = 0.9 +/- 7.9 mL/beat). This study, using strictly quantified AR volume, demonstrated little change in AR orifice size during diastole. When high aliasing velocities are chosen, the FC method can be useful for determining effective AR orifice size and regurgitant volume.

  3. MRI of the small bowel: can sufficient bowel distension be achieved with small volumes of oral contrast?

    PubMed

    Kinner, Sonja; Kuehle, Christiane A; Herbig, Sebastian; Haag, Sebastian; Ladd, Susanne C; Barkhausen, Joerg; Lauenstein, Thomas C

    2008-11-01

    Sufficient luminal distension is mandatory for small bowel imaging. However, patients often are unable to ingest volumes of currently applied oral contrast compounds. The aim of this study was to evaluate if administration of low doses of an oral contrast agent with high-osmolarity leads to sufficient and diagnostic bowel distension. Six healthy volunteers ingested at different occasions 150, 300 and 450 ml of a commercially available oral contrast agent (Banana Smoothie Readi-Cat, E-Z-EM; 194 mOsmol/l). Two-dimensional TrueFISP data sets were acquired in 5-min intervals up to 45 min after contrast ingestion. Small bowel distension was quantified using a visual five-grade ranking (5 = very good distension, 1 = collapsed bowel). Results were statistically compared using a Wilcoxon-Rank test. Ingestion of 450 ml and 300 ml resulted in a significantly better distension than 150 ml. The all-over average distension value for 450 ml amounted to 3.4 (300 ml: 3.0, 150 ml: 2.3) and diagnostic bowel distension could be found throughout the small intestine. Even 45 min after ingestion of 450 ml the jejunum and ileum could be reliably analyzed. Small bowel imaging with low doses of contrast leads to diagnostic distension values in healthy subjects when a high-osmolarity substance is applied. These findings may help to further refine small bowel MRI techniques, but need to be confirmed in patients with small bowel disorders.

  4. Investigation of CNTD Silicon Nitride on Complex Shapes.

    DTIC Science & Technology

    1980-02-06

    tubing) ! NH 3 + H 2 + N 2 SiCl4 + N2 Chamber Pressure, 4 2 To Manometer (copper tubing) t8 2 A: 2" DIA or 0 0 " To Pumping System _____________Pt/Pt-l3Rh...Total Gas Flow Rate: 47,350 cm3/min Gas Composition: N2 = 25,000 ml/min H2 = 20,600 ml/min Ar = 700 ml/min NH3 = 650 ml/min SiCl4 = 400 ml/min The...Values for SiCl4 were not available. In addition, the fractions of these two gases are extremely small in the overall gas composition. Individual

  5. OZONE CONTACTOR FLOW VISUALIZATION AND CHARACTERIZATION USING 3-DIMENSIONAL LASER INDUCED FLUORESCENCE

    EPA Science Inventory

    Hydrodynamics of ozone contactors have a crucial impact on efficient inactivation of pathogens such as Cryptosporidium as well as control of disinfection byproducts such as bromate. Improper mixing behaviors including short-circuiting, internal recirculation and presence...

  6. Cerebral autoregulation and flow/metabolism coupling during cardiopulmonary bypass: the influence of PaCO/sub 2/

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murkin, J.M.; Farrar, J.K.; Tweed, W.A.

    Measurement of /sup 133/Xe clearance and effluent cerebral venous blood sampling were used in 38 patients to determine the effects of cardiopulmonary bypass, and of maintaining temperature corrected or noncorrected PaCO/sub 2/ at 40 mm Hg on regulation of cerebral blood flow (CBF) and flow/metabolism coupling. After induction of anesthesia with diazepam and fentanyl, mean CBF was 25 ml X 100 g-1 X min-1 and cerebral oxygen consumption, 1.67 ml X 100 g-1 X min-1. Cerebral oxygen consumption during nonpulsatile cardiopulmonary bypass at 26 degrees C was reduced to 0.42 ml X 100 g-1 X min-1 in both groups. CBFmore » was reduced to 14-15 ml X 100 g-1 X min-1 in the non-temperature-corrected group (n = 21), was independent of cerebral perfusion pressure over the range of 20-100 mm Hg, but correlated with cerebral oxygen consumption. In the temperature-corrected group (n = 17), CBF varied from 22 to 32 ml X 100 g-1 X min-1, and flow/metabolism coupling was not maintained (i.e., CBF and cerebral oxygen consumption varied independently). However, variation in CBF correlated significantly with cerebral perfusion pressure over the pressure range of 15-95 mm Hg. This study demonstrates a profound reduction in cerebral oxygen consumption during hypothermic nonpulsatile cardiopulmonary bypass. When a non-temperature-corrected PaCO/sub 2/ of approximately 40 mm Hg was maintained, CBF was lower, and analysis of pooled data suggested that CBF regulation was better preserved, i.e., CBF was independent of pressure changes and dependent upon cerebral oxygen consumption.« less

  7. An axial distribution of seeding, proliferation, and osteogenic differentiation of MC3T3-E1 cells and rat bone marrow-derived mesenchymal stem cells across a 3D Thai silk fibroin/gelatin/hydroxyapatite scaffold in a perfusion bioreactor.

    PubMed

    Sinlapabodin, Salita; Amornsudthiwat, Phakdee; Damrongsakkul, Siriporn; Kanokpanont, Sorada

    2016-01-01

    In cell culture, a perfusion bioreactor provides effective transportation of nutrients, oxygen, and waste removal to and from the core of the scaffold. In addition, it provides mechanical stimuli for enhancing osteogenic differentiation. In this study, we used an axial distribution of cell numbers, alkaline phosphatase (ALP) enzyme activity, and calcium content across 4 cross-sections of 10mm thick scaffold, made of Thai silk fibroin (SF)/gelatin (G)/hydroxyapatite (HA), as a tool to evaluate the suitable perfusion flow rate. These evaluations cover all cellular developmental phases starting from seeding, to proliferation, and later osteogenic differentiation. Mouse pre-osteoblastic MC3T3-E1 cell lines were used as a cell model during seeding and proliferation. The bioreactor seeded scaffold provided more uniform cell distribution across the scaffold compared to centrifugal and agitation seeding, while the overall number of adhered cells from bioreactor seeding was slightly lower than agitation seeding. The dynamic culture using 1 ml/min perfusion flow rate (initial shear stress of 0.1 dyn/cm(2)) enabled statistically higher MC3T3-E1 proliferation, ALP activity, and calcium deposition than those observed in the static-culturing condition. However, the perfusion flow rate of 1 ml/min seemed not to be enough for enhancing ALP expression across all sections of the scaffold. Rat bone marrow derived stromal cells (rMSC) were used in the detachment test and osteogenic differentiation. It was found that perfusion flow rate of 5 ml/min caused statistically higher cell detachment than that of 1 and 3 ml/min. The perfusion flow rate of 3 ml/min gave the highest rMSC osteogenic differentiation on a SF/G/HA scaffold than other flow rates, as observed from the significantly highest number of ALP enzyme activity and the calcium content without any significant cell growth. In addition, all of these parameters were evenly distributed across all scaffold sections. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Axillary brachial plexus block duration with mepivacaine in patients with chronic renal failure. Case-control study.

    PubMed

    Mojica, V; Nieuwveld, D; Herrera, A E; Mestres, G; López, A M; Sala-Blanch, X

    2017-04-01

    Regional anaesthesia is commonly preferred for arteriovenous fistula (AVF) creation. Previous studies suggest a shorter block duration in patients with chronic renal failure, maybe because of the changes in regional blood flow. The aim of our study was to evaluate the duration of the axillary block with 1.5% mepivacaine in patients with chronic renal failure scheduled for AVF compared with healthy controls. Patients scheduled for AVF creation for the first time (GIRC) were included. They were compared with patients without renal failure (GC), with similar anthropometric characteristics. Ultrasound-guided axillary blocks with 20mL of 1.5% mepivacaine were performed on all patients. We evaluated onset time, humeral artery diameter and blood flow before and after the block, as well as the block duration. Twenty-three patients (GIRC: 12 and GC: 11) were included. No differences between groups were observed in block duration (GIRC: 227±43min vs GC: 229±27min; P=.781), or in onset time (GIRC: 13±5min vs GC: 12.2±3min; P=.477). The humeral blood flow before and after block was significantly lower in the GIRC (pre-block: GIRC: 52±21ml/min GC: 100±62ml/min; P=.034 and p ost block: GIRC: 130±57ml/min and GC: 274±182ml/min; P=.010). There was no significant correlation between the duration of the block and the preblock humeral blood flow (Spearman Rho: 0.106; P=.657) or the postblock humeral blood flow (Spearman Rho: 0.267; P=.254). The duration of the axillary block with 1.5% mepivacaine in patients with chronic renal failure was similar to that of the control patients. The duration of axillary brachial plexus block seems not to be related to changes in regional blood flow. Copyright © 2016 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Flow-injection chemiluminescence determination of ofloxacin and levofloxacin in pharmaceutical preparations and biological fluids.

    PubMed

    Sun, Hanwen; Li, Liqing; Chen, Xueyan

    2006-08-01

    A novel, rapid and sensitive analytical method is described for determination of ofloxacin and levofloxacin by enhanced chemiluminescence (CL) with flow-injection sampling. The method is based on the CL reaction of the Ce(IV)-Na2S2O4-ofloxacin/levofloxacin-H2SO2 system. The enhanced CL mechanism was developed and the optimum conditions for CL emission were investigated. The CL intensity was correlated linearly (r = 0.9988) with the concentration of ofloxacin (or levofloxacin) in the range of 1.0 x 10(-8) - 1.0 x 10(-7) g ml(-1) and 1.0 x 10(-7) - 6.0 x 10(-6) g ml(-1). The detection limit (S/N = 3) is 7 x 10(-9) g ml(-1). The relative standard derivation (RSD, n = 11) is 2.0% for ofloxacin at 4 x 10(-7) g ml(-1) and for levofloxacin at 6 x 10(-7) g ml(-1). This method has been successfully applied for the determination of ofloxacin and levofloxacin in pharmaceutical preparations and biological fluids with satisfactory results.

  10. A mathematical model to optimize the drain phase in gravity-based peritoneal dialysis systems.

    PubMed

    Akonur, Alp; Lo, Ying-Cheng; Cizman, Borut

    2010-01-01

    Use of patient-specific drain-phase parameters has previously been suggested to improve peritoneal dialysis (PD) adequacy. Improving management of the drain period may also help to minimize intraperitoneal volume (IPV). A typical gravity-based drain profile consists of a relatively constant initial fast-flow period, followed by a transition period and a decaying slow-flow period. That profile was modeled using the equation VD(t) = (V(D0) - Q(MAX) x t) xphi + (V(D0) x e(-alphat)) x (1 - phi), where V(D)(t) is the time-dependent dialysate volume; V(D0), the dialysate volume at the start of the drain; Q(MAX), the maximum drain flow rate; alpha, the exponential drain constant; and phi, the unit step function with respect to the flow transition. We simulated the effects of the assumed patient-specific maximum drain flow (Q(MAX)) and transition volume (psi), and the peritoneal volume percentage when transition occurs,for fixed device-specific drain parameters. Average patient transport parameters were assumed during 5-exchange therapy with 10 L of PD solution. Changes in therapy performance strongly depended on the drain parameters. Comparing 400 mL/85% with 200 mL/65% (Q(MAX/psi), drain time (7.5 min vs. 13.5 min) and IPV (2769 mL vs. 2355 mL) increased when the initial drain flow was low and the transition quick. Ultrafiltration and solute clearances remained relatively similar. Such differences were augmented up to a drain time of 22 minutes and an IPV of more than 3 L when Q(MAX) was 100 mL/min. The ability to model individual drain conditions together with water and solute transport may help to prevent patient discomfort with gravity-based PD. However, it is essential to note that practical difficulties such as displaced catheters and obstructed flow paths cause variability in drain characteristics even for the same patient, limiting the clinical applicability of this model.

  11. High flow through a nasal cannula and CPAP effect in a simulated infant model.

    PubMed

    Volsko, Teresa A; Fedor, Kathy; Amadei, Jason; Chatburn, Robert L

    2011-12-01

    Limited data are available to describe the CPAP effects that can be expected when using high flow with a traditional nasal cannula. To describe the relationship between the pressure generated at the airway opening and flow through a nasal cannula using a simulated infant model. We hypothesized that positive pressure generated by a standard cannula at flows > 2 L/min would be minimal and clinically unimportant. Nares were simulated with holes drilled in a plastic fixture. A nares template for CPAP prongs served as a sizing template for the holes. Small, medium, and large nares fixtures were constructed and connected to a lung simulator that simulated spontaneous breathing. Respiratory muscle pressure was simulated by setting a waveform and adjusting the amplitude to deliver a range of tidal volumes (V(T)) from 3 mL to 12 mL. Lung compliance and resistance were set at 0.5 mL/cm H(2)O and 125 cm H(2)O/L/s, respectively. Nasal cannulas were inserted in the model nares. We assured that the prong occlusion of the nares did not exceed 50%. Cannula flow was adjusted from 2-6 L/min in 1-L/min increments. Data were averaged over 20 breaths. Mean airway pressure and percent change in V(T) were recorded. The greatest effect on V(T) (mean ± SD 0.16 ± 0.10 mL) and pressure change (mean ± SD 0.7 ± 0.5 cm H(2)O) occurred with the premature cannula. The least effect on pressure (mean ± SD 0.3 ± 0.22 cm H(2)O) and V(T) change (mean ± SD 0.01 ± 0.02 mL) occurred with the infant cannula. Clinically important pressures were not generated by high flows with a standard nasal cannula. The differences in spontaneous V(T) across all flows were negligible.

  12. Coronary blood flow during cardiopulmonary resuscitation in swine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bellamy, R.F.; DeGuzman, L.R.; Pedersen, D.C.

    1984-01-01

    Recent papers have raised doubt as to the magnitude of coronary blood flow during closed-chest cardiopulmonary resuscitation. We will describe experiments that concern the methods of coronary flow measurement during cardiopulmonary resuscitation. Nine anesthetized swine were instrumented to allow simultaneous measurements of coronary blood flow by both electromagnetic cuff flow probes and by the radiomicrosphere technique. Cardiac arrest was caused by electrical fibrillation and closed-chest massage was performed by a Thumper (Dixie Medical Inc., Houston). The chest was compressed transversely at a rate of 66 strokes/min. Compression occupied one-half of the massage cycle. Three different Thumper piston strokes were studied:more » 1.5, 2, and 2.5 inches. Mean aortic pressure and total systemic blood flow measured by the radiomicrosphere technique increased as Thumper piston stroke was lengthened (mean +/- SD): 1.5 inch stroke, 23 +/- 4 mm Hg, 525 +/- 195 ml/min; 2 inch stroke, 33 +/- 5 mm Hg, 692 +/- 202 ml/min; 2.5 inch stroke, 40 +/- 6 mm Hg, 817 +/- 321 ml/min. Both methods of coronary flow measurement (electromagnetic (EMF) and radiomicrosphere (RMS)) gave similar results in technically successful preparations (data expressed as percent prearrest flow mean +/- 1 SD): 1.5 inch stroke, EMF 12 +/- 5%, RMS 16 +/- 5%; 2 inch stroke, EMF 30 +/- 6%, RMS 26 +/- 11%; 2.5 inch stroke, EMF 50 +/- 12%, RMS 40 +/- 20%. The phasic coronary flow signal during closed-chest compression indicated that all perfusion occurred during the relaxation phase of the massage cycle. We concluded that coronary blood flow is demonstrable during closed-chest massage, but that the magnitude is unlikely to be more than a fraction of normal.« less

  13. New intravascular flow sensor using fiber optics

    NASA Astrophysics Data System (ADS)

    Stenow, Erik N. D.

    1994-12-01

    A new sensor using fiber optics is suggested for blood flow measurements in small vessels. The sensor principle and a first evaluation on a flow model are presented. The new sensor uses small CO2 gas bubbles as flow markers for optical detection. When the bubbles pass an optical window, light emitted from one fiber is reflected and scattered into another fiber. The sensor has been proven to work in a 3 mm flow model using two 110 micrometers optical fibers and a 100 micrometers steel capillary inserted into a 1 mm guide wire. The evaluation of a sensor archetype shows that the new sensor provides a promising method for intravascular blood flow measurement in small vessels. The linearity for steady state flow is studied in the flow interval 30 - 130 ml/min. comparison with ultrasound Doppler flowmetry was performed for pulsatile flow in the interval 25 - 125 ml/min. with a pulse length between 0.5 and 2 s. The use of intravascular administered CO2 in small volumes is harmless because the gas is rapidly dissolved in whole blood.

  14. ATP mediates flow-induced NO production in thick ascending limbs

    PubMed Central

    Hong, Nancy J.; Garvin, Jeffrey L.

    2012-01-01

    Mechanical stimulation caused by increasing flow induces nucleotide release from many cells. Luminal flow and extracellular ATP stimulate production of nitric oxide (NO) in thick ascending limbs. However, the factors that mediate flow-induced NO production are unknown. We hypothesized that luminal flow stimulates thick ascending limb NO production via ATP. We measured NO in isolated, perfused rat thick ascending limbs using the fluorescent dye DAF FM. The rate of increase in dye fluorescence reflects NO accumulation. Increasing luminal flow from 0 to 20 nl/min stimulated NO production from 17 ± 16 to 130 ± 37 arbitrary units (AU)/min (P < 0.02). Increasing flow from 0 to 20 nl/min raised ATP release from 4 ± 1 to 21 ± 6 AU/min (P < 0.04). Hexokinase (10 U/ml) plus glucose, which consumes ATP, completely prevented the measured increase in ATP. Luminal flow did not increase NO production in the presence of luminal and basolateral hexokinase (10 U/ml). When flow was increased with the ATPase apyrase in both luminal and basolateral solutions (5 U/ml), NO levels did not change significantly. The P2 receptor antagonist suramin (300 μmol/l) reduced flow-induced NO production by 83 ± 25% (P < 0.03) when added to both and basolateral sides. Luminal hexokinase decreased flow-induced NO production from 205.6 ± 85.6 to 36.6 ± 118.6 AU/min (P < 0.02). Basolateral hexokinase also reduced flow-induced NO production. The P2X receptor-selective antagonist NF023 (200 μmol/l) prevented flow-induced NO production when added to the basolateral side but not the luminal side. We conclude that ATP mediates flow-induced NO production in the thick ascending limb likely via activation of P2Y receptors in the luminal and P2X receptors in the basolateral membrane. PMID:22496412

  15. High-performance liquid chromatographic assay for the determination of Aloe Emodin in mouse plasma.

    PubMed

    Zaffaroni, M; Mucignat, C; Pecere, T; Zagotto, G; Frapolli, R; D'Incalci, M; Zucchetti, M

    2003-10-25

    An isocratic high-performance liquid chromatography (HPLC) method was developed and validated to determine Aloe Emodin (AE) in mouse plasma. The analysis required 0.3 ml of plasma and involves extraction with dichloromethane. The HPLC separation was carried out on Symmetry Shield RP18, a mobile phase of methanol-water-acetic acid (65:35:0.2) and fluorescence detection at lambda(ex)=410 nm and lambda(em)=510 nm. The retention time of AE was 11.7 min. The assay was linear from 10 to 1,000 ng/ml (r2 > or = 0.999), showed intra- and inter-day precision within 7.8 and 4.7%, and accuracy of 87.3-105.7%. Detection limit (LOD) and quantification limit (LOQ) were 4.5 and 5 ng/ml, respectively. The method was applied to determine for the first time the pharmacokinetic of AE in mice.

  16. ARMY GAS-COOLED REACTOR SYSTEMS PROGRAM. Quarterly Progress Report, October 1-December 31, 1963

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1964-02-15

    The ML-1 power plant did not operate during the report period; low power reactor physics and shielding experiments were conducted with the ML-1 reactor. Evaluation of moderate corrosion observed on aluminum parts exposed to the ML-1 shield solution indicated no loss of performance capability. Preliminary tests showed that the corrosion probably was caused by heavy metal ions or chlorides in the solution, Massive corrosion observed on the ML-1 fuel element lower spiders was attributed to sub-standard material; failure of some spiders was attributed to a combination of corrosion and sub-standard fabrication. Evaluation indicated that the upper spiders will perform satisfactorilymore » for the design lifetime. Modification, repair, and reassembly of the CSN-1A t-c set was completed. Operation demonstrated bearing stability, but showed that the turbine effective flow area was too large. A bypass flow path in the turbine was being corrected. The TCS-670 t-c set will be stored indefinitely. Since a commercial alternator will be used for the ML-1A, further development of the brushless alternator was postponed indefinitely. Evaluation revealed that the ML-1 improved precooler design was not compatible with ML-1A requirements. Operntion of the IB-17R-2 and -3 test elements in the GETR continued without incident. Preliminary design of the ML-1A power plant was initiated. Design of modifications to the GCRE facility to adapt it to testing the ML-1 reactor skid was initiated. (auth)« less

  17. CytometryML: a data standard which has been designed to interface with other standards

    NASA Astrophysics Data System (ADS)

    Leif, Robert C.

    2007-02-01

    Because of the differences in the requirements, needs, and past histories including existing standards of the creating organizations, a single encompassing cytology-pathology standard will not, in the near future, replace the multiple existing or under development standards. Except for DICOM and FCS, these standardization efforts are all based on XML. CytometryML is a collection of XML schemas, which are based on the Digital Imaging and Communications in Medicine (DICOM) and Flow Cytometry Standard (FCS) datatypes. The CytometryML schemas contain attributes that link them to the DICOM standard and FCS. Interoperability with DICOM has been facilitated by, wherever reasonable, limiting the difference between CytometryML and the previous standards to syntax. In order to permit the Resource Description Framework, RDF, to reference the CytometryML datatypes, id attributes have been added to many CytometryML elements. The Laboratory Digital Imaging Project (LDIP) Data Exchange Specification and the Flowcyt standards development effort employ RDF syntax. Documentation from DICOM has been reused in CytometryML. The unity of analytical cytology was demonstrated by deriving a microscope type and a flow cytometer type from a generic cytometry instrument type. The feasibility of incorporating the Flowcyt gating schemas into CytometryML has been demonstrated. CytometryML is being extended to include many of the new DICOM Working Group 26 datatypes, which describe patients, specimens, and analytes. In situations where multiple standards are being created, interoperability can be facilitated by employing datatypes based on a common set of semantics and building in links to standards that employ different syntax.

  18. Shocking Path of Least Resistance Shines Light on Subsurface by Revealing the Paths of Water and the Presence of Faults: Stacked EM Case Studies over Barite Hills Superfund Site in South Carolina

    NASA Astrophysics Data System (ADS)

    Haggar, K. S.; Nelson, H. R., Jr.; Berent, L. J.

    2017-12-01

    The Barite Hills/Nevada Gold Fields mines are in Late Proterozoic and early Paleozoic rocks of the gold and iron sulfides rich Carolina slate belt. The mines were active from 1989 to1995. EPA and USGS site investigations in 2003 resulted in the declaration of the waste pit areas as a superfund site. The USGS and private consulting firms have evaluated subsurface water flow paths, faults & other groundwater-related features at this superfund site utilizing 2-D conductivity & 3-D electromagnetic (EM) surveys. The USGS employed conductivity to generate instantaneous 2-D profiles to evaluate shallow groundwater patterns. Porous regolith sediments, contaminated water & mine debris have high conductivity whereas bedrock is identified by its characteristic low conductivity readings. Consulting contractors integrated EM technology, magnetic & shallow well data to generate 3-D images of groundwater flow paths at given depths across the superfund site. In so doing several previously undetected faults were identified. Lighting strike data was integrated with the previously evaluated electrical and EM data to determine whether this form of natural-sourced EM data could complement and supplement the more traditional geophysical data described above. Several lightning attributes derived from 3-D lightning volumes were found to correlate to various features identified in the previous geophysical studies. Specifically, the attributes Apparent Resistivity, Apparent Permittivity, Peak Current & Tidal Gravity provided the deepest structural geological framework & provided insights into rock properties & earth tides. Most significantly, Peak Current showed remarkable coincidence with the preferred groundwater flow map identified by one of the contractors utilizing EM technology. This study demonstrates the utility of robust integrated EM technology applications for projects focused on hydrology, geohazards to dams, levees, and structures, as well as mineral and hydrocarbon exploration.

  19. Augmented catecholamine uptake by the heart during hemorrhage in the conscious dog

    NASA Technical Reports Server (NTRS)

    Woodman, O. L.; Amano, J.; Hintze, T. H.; Vatner, S. F.

    1986-01-01

    Changes in arterial and coronary sinus concentrations of norepinephrine (NE) and epinephrine (E) in response to hemorrhage were examined in conscious dogs. Hemorrhage (45 +/- 3.2 ml/kg) decreased mean arterial pressure by 47 +/- 6%, left ventricular (LV) dP/dt by 38 +/- 6%, and mean left circumflex coronary blood flow by 47 +/- 6%, while heart rate increased by 44 +/- 13%. Increases in concentrations of arterial NE (5,050 +/- 1,080 from 190 +/- 20 pg/ml) and E (12,700 +/- 3,280 from 110 +/- 20 pg/ml) were far greater than increases in coronary sinus NE (1,700 +/- 780 from 270 +/- 50 pg/ml) and E (4,300 +/- 2,590 from 90 +/- 10 pg/ml). Net release of NE from the heart at rest was converted to a fractional extraction of 66 +/- 9% after hemorrhage. Fractional extraction of E increased from 16 +/- 6% at rest to 73 +/- 8% after hemorrhage. In cardiac-denervated dogs, hemorrhage (46 +/- 2.8 ml/kg) decreased mean arterial pressure by 39 +/- 15%, LV dP/dt by 36 +/- 10%, and mean left circumflex coronary blood flow by 36 +/- 13%, while heart rate increased by 24 +/- 10%. Hemorrhage increased arterial NE (1,740 +/- 150 from 210 +/- 30 pg/ml) and E (3,050 +/- 880 from 140 +/- 20 pg/ml) more than it increased coronary sinus NE (460 +/- 50 from 150 +/- 30 pg/ml) and E (660 +/- 160 from 90 +/- 20 pg/ml) but significantly less (P less than 0.05) than observed in intact dogs. These experiments indicate that hemorrhage, unlike exercise and sympathetic nerve stimulation, does not induce net overflow of NE from the heart.(ABSTRACT TRUNCATED AT 250 WORDS).

  20. Practical utility of on-line clearance and blood temperature monitors as noninvasive techniques to measure hemodialysis blood access flow.

    PubMed

    Fontseré, Néstor; Blasco, Miquel; Maduell, Francisco; Vera, Manel; Arias-Guillen, Marta; Herranz, Sandra; Blanco, Teresa; Barrufet, Marta; Burrel, Marta; Montaña, Javier; Real, Maria Isabel; Mestres, Gaspar; Riambau, Vicenç; Campistol, Josep M

    2011-01-01

    Access blood flow (Qa) measurements are recommended by the current guidelines as one of the most important components in vascular access maintenance programs. This study evaluates the efficiency of Qa measurement with on-line conductivity (OLC-Qa) and blood temperature monitoring (BTM-Qa) in comparison with the gold standard saline dilution method (SDM-Qa). 50 long-term hemodialysis patients (42 arteriovenous fistulas/8 arteriovenous grafts) were studied. Bland-Altman and Lin's coefficient (ρ(c)) were used to study accuracy and precision. Mean values were 1,021.7 ± 502.4 ml/min SDM-Qa, 832.8 ± 574.3 ml/min OLC-Qa (p = 0.007) and 1,094.9 ± 491.9 ml/min with BTM-Qa (p = NS). Biases and ρ(c) obtained were -188.8 ml/min (ρ(c) 0.58) OLC-Qa and 73.2 ml/min (ρ(c) 0.89) BTM-Qa. The limits of agreement (bias ± 1.96 SD) obtained were from -1,119 to 741.3 ml/min (OLC-Qa) and -350.6 to 497.2 ml/min (BTM-Qa). BTM-Qa and OLC-Qa are valid noninvasive and practical methods to estimate Qa, although BTM-Qa was more accurate and had better concordance than OLC-Qa compared with SDM-Qa. Copyright © 2010 S. Karger AG, Basel.

  1. Gas Exchange of Algae

    PubMed Central

    Ammann, Elizabeth C. B.; Lynch, Victoria H.

    1967-01-01

    The oxygen production of a photosynthetic gas exchanger containing Chlorella pyrenoidosa (1% packed cell volume) was measured when various concentrations of carbon dioxide were present within the culture unit. The internal carbon dioxide concentrations were obtained by manipulating the entrance gas concentration and the flow rate. Carbon dioxide percentages were monitored by means of electrodes placed directly in the nutrient medium. The concentration of carbon dioxide in the nutrient medium which produced maximal photosynthesis was in the range of 1.5 to 2.5% by volume. Results were unaffected by either the level of carbon dioxide in the entrance gas or the rate of gas flow. Entrance gases containing 2% carbon dioxide flowing at 320 ml/min, 3% carbon dioxide at 135 ml/min, and 4% carbon dioxide at 55 ml/min yielded optimal carbon dioxide concentrations in the particular unit studied. By using carbon dioxide electrodes implanted directly in the gas exchanger to optimize the carbon dioxide concentration throughout the culture medium, it should be possible to design more efficient large-scale units. PMID:4382391

  2. Effect of gravitational and inertial forces on vertical distribution of pulmonary blood flow

    NASA Technical Reports Server (NTRS)

    Chevalier, P. A.; Reed, J. H., Jr.; Vandenberg, R. A.; Wood, E. H.

    1978-01-01

    Vertical distribution of pulmonary blood flow (VDPBF) was studied, using radioactive microsphere emboli, in dogs without thoracotomy in the right decubitus position during exposure to lateral accelerations of 1, 2, 4, and 6 G. At all levels of force environment studied, an inverse linear relationship was observed between vertical height in the thorax and pulmonary blood flow (ml/min/ml lung tissue) with a decrease in flow to the most dependent region of the lung despite large increases in intravascular pressures at this site. Changes in blood flow were smallest at the mid-lung level, the hydrostatic 'balance point' for vascular and pleural pressures. These force environment-dependent changes in VDPBF are not readily explainable by the Starling resistor analog. Gravity-dependent regional differences in pleural and associated interstitial pressures, plus possible changes in vascular tone resulting from inadequate aeration of blood in the most dependent regions of the lung, probably also affect VDPBF.

  3. Development of a silicone hollow fiber membrane oxygenator for ECMO application.

    PubMed

    Yamane, S; Ohashi, Y; Sueoka, A; Sato, K; Kuwana, J; Nosé, Y

    1998-01-01

    A new silicone hollow fiber membrane oxygenator for extracorporeal membrane oxygenation (ECMO) was developed using an ultrathin silicone hollow fiber, with a 300 microm outer diameter and a wall thickness of 50 microm. The hollow fibers were mechanically cross-wound on the flow distributor to achieve equal distribution of blood flow without changing the fiber shape. The housing, made of silicone coated acryl, was 236 mm long with an inner diameter of 60 mm. The surface area was 1.0 m2 for prototype 211, and 1.1 m2 for prototype 209. The silicone fiber length was 150 mm, and the silicone membrane packing density was 43% for prototype 211 and 36% for prototype 209. Prototype 211 has a priming volume of 208 ml, and prototype 209 has a priming volume of 228 ml. The prototype 211 oxygenator demonstrates a gas transfer rate of 120 +/- 5 ml/min (mean +/- SD) for O2 and 67 +/- 12 ml/min for CO2 under 2 L of blood flow and 4 L of O2 gas flow. Prototype 209 produced the same values. The blood side pressure drop was low compared with the silicone sheet oxygenator (Avecor, 1500ECMO). These results showed that this new oxygenator for ECMO had efficiency similar to the silicone sheet oxygenator that has a 50% larger surface area. These results suggest that the new generation oxygenator using an ultrathin silicone hollow fiber possesses sufficient gas transfer performance for long-term extracorporeal lung support.

  4. Cytometry standards continuum

    NASA Astrophysics Data System (ADS)

    Leif, Robert C.; Spidlen, Josef; Brinkman, Ryan R.

    2008-02-01

    Introduction: The International Society for Analytical Cytology, ISAC, is developing a new combined flow and image Analytical Cytometry Standard (ACS). This standard needs to serve both the research and clinical communities. The clinical medicine and clinical research communities have a need to exchange information with hospital and other clinical information systems. Methods: 1) Prototype the standard by creating CytometryML and a RAW format for binary data. 2) Join the ISAC Data Standards Task Force. 3) Create essential project documentation. 4) Cooperate with other groups by assisting in the preparation of the DICOM Supplement 122: Specimen Module and Pathology Service-Object Pair Classes. Results: CytometryML has been created and serves as a prototype and source of experience for the following: the Analytical Cytometry Standard (ACS) 1.0, the ACS container, Minimum Information about a Flow Cytometry Experiment (MIFlowCyt), and Requirements for a Data File Standard Format to Describe Flow Cytometry and Related Analytical Cytology Data. These requirements provide a means to judge the appropriateness of design elements and to develop tests for the final ACS. The requirements include providing the information required for understanding and reproducing a cytometry experiment or clinical measurement, and for a single standard for both flow and digital microscopic cytometry. Schemas proposed by other members of the ISAC Data Standards Task Force (e.g, Gating-ML) have been independently validated and have been integrated with CytometryML. The use of netCDF as an element of the ACS container has been proposed by others and a suggested method of its use is proposed.

  5. The Unstimulated Salivary Flow Rate in a Jordanian Healthy Adult Population

    PubMed Central

    Sawair, Faleh A.; Ryalat, Soukaina; Shayyab, Mohammad; Saku, Takashi

    2009-01-01

    Background Early diagnosis of xerostomia is very important for oral health. The purpose of this study was to determine the unstimulated whole salivary flow rates (UWSFR) in a Jordanian Arab population aged 15 years and older. The effect of age, gender, height, weight, body mass index (BMI), smoking, alcohol consumption, and dental conditions, on UWSFR was also investigated. Methods The study was conducted on 244 subjects, 110 males and 134 females, with an average age of 33 ± 15.5 years. They were healthy, unmedicated, and with no history of dry mouth. Unstimulated whole saliva was collected during five minutes, and UWSFRs (ml/min) were determined. Data were analyzed by univariate analysis and multivariate regression analysis. Results The mean UWSFR was 0.46 ± 0.25 ml/min (range: 0.10-1.6 ml/min). Eighteen patients (7.4%) had UWSFR between < 0.20 ml/min. In univariate analysis, UWSFR was significantly affected by age, BMI, number of missing and restored teeth, and DMFT score. Regression analysis revealed that only age and number of missing teeth were of significance in explaining the variability of the UWSFR. Conclusions We established basic standard values of UWSFR to be used in the evaluation of Jordanian patients with complaints of xerostomia and to be compared to data reported in other studies. UWSFR 0.1 ml/min could be considered the cut-off value that distinguishes normal from abnormal salivary function in this healthy unmedicated population. Keywords Whole saliva flow rate; Unstimulated; Jordan PMID:22461872

  6. Gastrointestinal hemodynamics during compensation for hemorrhage and measurement of Pmcf.

    PubMed

    Rothe, C F; Maass-Moreno, R

    1994-03-01

    To quantify the degree of autonomic reflex control of the gastrointestinal vasculature, we studied the responses to a 10-ml/kg hemorrhage or transfusion and autonomic blockade in fentanyl- and pentobarbital-anesthetized dogs. The active total blood volume was estimated by indocyanine green dilution. Transfusion and hemorrhage did not significantly change gastrointestinal vascular compliance [1.82 +/- 0.68 (SD) ml/mmHg], but autonomic blockade with hexamethonium and atropine increased it by 0.57 +/- 0.37 ml/mmHg. Neither hemorrhage nor autonomic blockade significantly changed gastrointestinal vascular resistance from its control value of 10.8 +/- 4 mmHg.ml-1.min.kg body wt, but transfusion reduced it by 3.0 +/- 1.2 mmHg.ml-1.min.kg body wt. The ratio of gastrointestinal vascular resistance to total peripheral resistance was not significantly changed, however. We conclude that vascular compliance and resistance of the gastrointestinal bed are minimally influenced by the autonomic nervous system under the conditions studied. Portal pressure and flow measurements (transit-time ultrasound) during the above maneuvers were also combined with estimations of mean circulatory filling pressure (Pmcf) to test the hypothesis that, when the heart is stopped to measure Pmcf, portal pressure equals central venous pressure (Pcv) and hence that portal flow is zero. Seven seconds after the heart was stopped, portal venous pressure (Ppv) remained 0.83 +/- 0.78 mmHg higher than Pcv and portal flow decreased to only 25% of its control value. However, gastrointestinal compliance times (Ppv-Pcv), an estimate of the extra distending volume, was only 0.07 +/- 0.07 ml/kg body wt. Thus we conclude that the error in estimating Pmcf, given this (Ppv-Pcv) difference, is physiologically insignificant.

  7. A general probabilistic model for group independent component analysis and its estimation methods

    PubMed Central

    Guo, Ying

    2012-01-01

    SUMMARY Independent component analysis (ICA) has become an important tool for analyzing data from functional magnetic resonance imaging (fMRI) studies. ICA has been successfully applied to single-subject fMRI data. The extension of ICA to group inferences in neuroimaging studies, however, is challenging due to the unavailability of a pre-specified group design matrix and the uncertainty in between-subjects variability in fMRI data. We present a general probabilistic ICA (PICA) model that can accommodate varying group structures of multi-subject spatio-temporal processes. An advantage of the proposed model is that it can flexibly model various types of group structures in different underlying neural source signals and under different experimental conditions in fMRI studies. A maximum likelihood method is used for estimating this general group ICA model. We propose two EM algorithms to obtain the ML estimates. The first method is an exact EM algorithm which provides an exact E-step and an explicit noniterative M-step. The second method is an variational approximation EM algorithm which is computationally more efficient than the exact EM. In simulation studies, we first compare the performance of the proposed general group PICA model and the existing probabilistic group ICA approach. We then compare the two proposed EM algorithms and show the variational approximation EM achieves comparable accuracy to the exact EM with significantly less computation time. An fMRI data example is used to illustrate application of the proposed methods. PMID:21517789

  8. The effect of the solution flow rate on the properties of zinc oxide (ZnO) thin films deposited by ultrasonic spray

    NASA Astrophysics Data System (ADS)

    Attaf, A.; Benkhetta, Y.; Saidi, H.; Bouhdjar, A.; Bendjedidi, H.; Nouadji, M.; Lehraki, N.

    2015-03-01

    In this work, we used a system based on ultrasonic spray pyrolysis technique. By witch, we have deposited thin films of zinc oxide (ZnO) with the variation of solution flow rate from 50 ml / h to 150 ml / h, and set other parameters such as the concentration of the solution, the deposition time, substrate temperature and the nozzel -substrate distance. In order to study the influence of the solution flow rate on the properties of the films produced, we have several characterization techniques such as X-ray diffraction to determine the films structure, the scanning electron microscopy SEM for the morphology of the surfaces, EDS spectroscopy for the chemical composition, UV-Visible-Nir spectroscopy for determination the optical proprieties of thin films.The experimental results show that: the films have hexagonal structure at the type (wurtzite), the average size of grains varies from 20.11 to 32.45 nm, the transmittance of the films equals 80% in visible rang and the band gap is varied between 3.274 and 3.282 eV, when the solution flow rate increases from 50 to 150 ml/h.

  9. Acute control of pulmonary regurgitation with a balloon "valve". An experimental investigation.

    PubMed

    Siwek, L G; Applebaum, R E; Jones, M; Clark, R E

    1985-09-01

    Operations for certain congenital cardiac lesions can produce pulmonary regurgitation. Pulmonary regurgitation contributes to right ventricular dysfunction, which may cause early postoperative morbidity and mortality. To ameliorate the problems of pulmonary regurgitation during the early postoperative period, we evaluated a method for its acute control. Complete pulmonary valvectomy was performed utilizing inflow occlusion in eight sheep. A catheter with a 15 ml spherical balloon was positioned in the pulmonary arterial trunk; its inflation and deflation were regulated by an intra-aortic balloon pump unit. Blood flow from the pulmonary arterial trunk and forward and regurgitant fraction were determined from electromagnetic flow transducer recordings. The regurgitant fraction with uncontrolled pulmonary regurgitation was 38% +/- 3% (forward flow = 42 +/- 5 ml/beat and regurgitant flow = 16 +/- 2 ml/beat). Inflation of the balloon during diastole was timed to completely eliminate pulmonary regurgitation. This balloon control of pulmonary regurgitation increased pulmonary arterial diastolic pressure from 12 +/- 1 to 17 +/- 1 mm Hg (p less than 0.0001) and decreased pulmonary arterial systolic pressure from 31 +/- 3 to 27 +/- 1 mm Hg (p = 0.06). Pulmonary arterial pulse pressure decreased from 19 +/- 3 to 9 +/- 1 mm Hg (p less than 0.003). Elimination of pulmonary regurgitation decreased right ventricular stroke volume (25 +/- 3 versus 42 +/- 5 ml/beat, p less than 0.0002) and resulted in a 46% reduction in right ventricular stroke work (5.0 +/- 0.6 versus 9.4 +/- 1.0 gm-m/beat, p less than 0.001) with no change in net forward pulmonary artery flow. Thus, acute pulmonary regurgitation can be controlled and this control improves overall hemodynamic status and decreases right ventricular work.

  10. Current challenges for pre-earthquake electromagnetic emissions: shedding light from micro-scale plastic flow, granular packings, phase transitions and self-affinity notion of fracture process

    NASA Astrophysics Data System (ADS)

    Eftaxias, K.; Potirakis, S. M.

    2013-10-01

    Are there credible electromagnetic (EM) potential earthquake (EQ) precursors? This a question debated in the scientific community and there may be legitimate reasons for the critical views. The negative view concerning the existence of EM potential precursors is enhanced by features that accompany their observation which are considered as paradox ones, namely, these signals: (i) are not observed at the time of EQs occurrence and during the aftershock period, (ii) are not accompanied by large precursory strain changes, (iii) are not accompanied by simultaneous geodetic or seismological precursors and (iv) their traceability is considered problematic. In this work, the detected candidate EM potential precursors are studied through a shift in thinking towards the basic science findings relative to granular packings, micron-scale plastic flow, interface depinning, fracture size effects, concepts drawn from phase transitions, self-affine notion of fracture and faulting process, universal features of fracture surfaces, recent high quality laboratory studies, theoretical models and numerical simulations. We try to contribute to the establishment of strict criteria for the definition of an emerged EM anomaly as a possibly EQ-related one, and to the explanation of potential precursory EM features which have been considered as paradoxes. A three-stage model for EQ generation by means of pre-EQ fracture-induced EM emissions is proposed. The claim that the observed EM potential precursors may permit a real-time and step-by-step monitoring of the EQ generation is tested.

  11. Phasic changes in human right coronary blood flow before and after repair of aortic insufficiency.

    PubMed

    Folts, J D; Rowe, G G; Kahn, D R; Young, W P

    1979-02-01

    We have shown previously that acute aortic insufficiency in chronically instrumented dogs reverses the normally high ratio of diastolic to systolic coronary blood flow. Phasic blood flow in the dominant right coronary artery was measured directly with an electromagnetic flow meter during surgery in eight patients with severe aortic insufficiency before and after relacement of the aortic valve. Before the insufficiency was eliminated, right coronary flow average 116 +/- 37 ml./minute and the diastolic to systolic flow ratio was 0.88 +/- 17. Mean arterial blood pressure averaged 106 +/- 17 mm. Hg, heart rate 84 +/- 19 beats/minute, and mean diastolic pressure averaged 67 +/- 10 mm. Hg. After the aortic valve was replaced with an average heart rate of 90 +/- 15 and mean blood pressure of 103 +/- 13 mm. Hg, the average right coronary blood flow increased to 180 +/- 40 ml./minute with a D/S ratio of 2.18 +/- 0.8. In all cases the right coronary blood flow increased after the aortic insufficiency was eliminated surgically. Right coronary flow probably increased because of the improved diastolic perfusion pressure and the change from predominantly systolic to diastolic coronary flow.

  12. Plunging Plates Cause a Stir.

    ERIC Educational Resources Information Center

    Weisburd, Stefi

    1986-01-01

    Reviews current ideas and research findings related to the flow patterns of mantle rocks. Highlights the components of the two-layer convection and whole-mantle models of mantle flow. Proposes that mantle flow is the key to understanding how the earth has cooled and chemically evolved. (ML)

  13. Effects of spaceflight on human calf hemodynamics

    NASA Technical Reports Server (NTRS)

    Watenpaugh, D. E.; Buckey, J. C.; Lane, L. D.; Gaffney, F. A.; Levine, B. D.; Moore, W. E.; Wright, S. J.; Blomqvist, C. G.

    2001-01-01

    Chronic microgravity may modify adaptations of the leg circulation to gravitational pressures. We measured resting calf compliance and blood flow with venous occlusion plethysmography, and arterial blood pressure with sphygmomanometry, in seven subjects before, during, and after spaceflight. Calf vascular resistance equaled mean arterial pressure divided by calf flow. Compliance equaled the slope of the calf volume change and venous occlusion pressure relationship for thigh cuff pressures of 20, 40, 60, and 80 mmHg held for 1, 2, 3, and 4 min, respectively, with 1-min breaks between occlusions. Calf blood flow decreased 41% in microgravity (to 1.15 +/- 0.16 ml x 100 ml(-1) x min(-1)) relative to 1-G supine conditions (1.94 +/- 0.19 ml x 100 ml(-1) x min(-1), P = 0.01), and arterial pressure tended to increase (P = 0.05), such that calf vascular resistance doubled in microgravity (preflight: 43 +/- 4 units; in-flight: 83 +/- 13 units; P < 0.001) yet returned to preflight levels after flight. Calf compliance remained unchanged in microgravity but tended to increase during the first week postflight (P > 0.2). Calf vasoconstriction in microgravity qualitatively agrees with the "upright set-point" hypothesis: the circulation seeks conditions approximating upright posture on Earth. No calf hemodynamic result exhibited obvious mechanistic implications for postflight orthostatic intolerance.

  14. Cholecalciferol, Calcitriol, and Vascular Function in CKD: A Randomized, Double-Blind Trial.

    PubMed

    Kendrick, Jessica; Andrews, Emily; You, Zhiying; Moreau, Kerrie; Nowak, Kristen L; Farmer-Bailey, Heather; Seals, Douglas R; Chonchol, Michel

    2017-09-07

    High circulating vitamin D levels are associated with lower cardiovascular mortality in CKD, possibly by modifying endothelial function. We examined the effect of calcitriol versus cholecalciferol supplementation on vascular endothelial function in patients with CKD. We performed a prospective, double-blind, randomized trial of 128 adult patients with eGFR=15-44 ml/min per 1.73 m 2 and serum 25-hydroxyvitamin D level <30 ng/ml at the University of Colorado. Participants were randomly assigned to oral cholecalciferol (2000 IU daily) or calcitriol (0.5 μ g) daily for 6 months. The primary end point was change in brachial artery flow-mediated dilation. Secondary end points included changes in circulating markers of mineral metabolism and circulating and cellular markers of inflammation. One hundred and fifteen patients completed the study. The mean (SD) age and eGFR of participants were 58±12 years old and 33.0±10.2 ml/min per 1.73 m 2 , respectively. There were no significant differences between groups at baseline. After 6 months, neither calcitriol nor cholecalciferol treatment resulted in a significant improvement in flow-mediated dilation (mean±SD percentage flow-mediated dilation; calcitriol: baseline 4.8±3.1%, end of study 5.1±3.6%; cholecalciferol: baseline 5.2±5.2%, end of study 4.7±3.6%); 25-hydroxyvitamin D levels increased significantly in the cholecalciferol group compared with the calcitriol group (cholecalciferol: 11.0±9.5 ng/ml; calcitriol: -0.8±4.8 ng/ml; P <0.001). Parathyroid hormone levels decreased significantly in the calcitriol group compared with the cholecalciferol group (median [interquartile range]; calcitriol: -22.1 [-48.7-3.5] pg/ml; cholecalciferol: -0.3 [-22.6-16.9] pg/ml; P =0.004). Six months of therapy with calcitriol or cholecalciferol did not improve vascular endothelial function or improve inflammation in patients with CKD. Copyright © 2017 by the American Society of Nephrology.

  15. BIODEGRADATION OF METHYL TERT-BUTYL ETHER USING AN INNOVATIVE BIOMASS CONCENTRATOR REACTOR

    EPA Science Inventory

    The aerobic biodegradation of methyl tert-butyl ether (MTBE) was investigated using a pilot-scale Biomass Concentrator Reactor (BCR). The reactor was operated for a year at a flow rate of 2500 L/d of Cincinnati dechlorinated tap water and an influent MTBE concentration o...

  16. An EM Algorithm for Maximum Likelihood Estimation of Process Factor Analysis Models

    ERIC Educational Resources Information Center

    Lee, Taehun

    2010-01-01

    In this dissertation, an Expectation-Maximization (EM) algorithm is developed and implemented to obtain maximum likelihood estimates of the parameters and the associated standard error estimates characterizing temporal flows for the latent variable time series following stationary vector ARMA processes, as well as the parameters defining the…

  17. Hybrid polymer composite membrane for an electromagnetic (EM) valveless micropump

    NASA Astrophysics Data System (ADS)

    Said, Muzalifah Mohd; Yunas, Jumril; Bais, Badariah; Azlan Hamzah, Azrul; Yeop Majlis, Burhanuddin

    2017-07-01

    In this paper, we report on a hybrid membrane used as an actuator in an electromagnetically driven valveless micropump developed using MEMS processes. The membrane structure consists of the combination of a magnetic polymer composite membrane and an attached bulk permanent magnet which is expected to have a compact structure and a strong magnetic force with maintained membrane flexibility. A soft polymeric material made of polydimethylsiloxane (PDMS) is initially mixed with neodymium magnetic particles (NdFeB) to form a magnetic polymer composite membrane. The membrane is then bonded with the PDMS based microfluidic part, developed using soft lithography process. The developed micropump was tested in terms of the actuator membrane deflection capability and the fluidic flow of the injected fluid sample through the microfluidic channel. The experimental results show that the magnetic composite actuator membrane with an attached bulk permanent magnet is capable of producing a maximum membrane deflection of up to 106 µm. The functionality test of the electromagnetic (EM) actuator for fluid pumping purposes was done by supplying an AC voltage with various amplitudes, signal waves and frequencies. A wide range of sample injection rates from a few µl min-1 to tens of nl min-1 was achieved with a maximum flow rate of 6.6 µl min-1. The injection flow rate of the EM micropump can be controlled by adjusting the voltage amplitude and frequency supplied to the EM coil, to control the membrane deflection in the pump chamber. The designed valveless EM micropump has a very high potential to enhance the drug delivery system capability in biomedical applications.

  18. Factors associated with subendocardial ischemia risk in patients on hemodialysis.

    PubMed

    Silva, Bruno Caldin da; Sanjuan, Adriano; Costa-Hong, Valéria; Reis, Luciene Dos; Graciolli, Fabiana; Consolim-Colombo, Fernanda; Bortolotto, Luiz Aparecido; Moyses, Rosa Maria Affonso; Elias, Rosilene Motta

    2016-01-01

    Bone metabolism disorder (BMD) and vascular dysfunction contribute to excess cardiovascular mortality observed in hemodialysis patients. Vascular dysfunction, a new marker of atherosclerosis, can play a role in this risk. Even though associated with higher mortality in the general population, such vascular evaluation in patients on hemodialysis has not been extensively studied. In this cross-sectional study, hemodialysis patients were submitted to flow-mediated dilation, subendocardial viability ratio (SEVR) and ejection duration index assessment, in order to estimate the impact of BMD markers on vascular dysfunction. A matched cohort of patients with (n = 16) and without (n = 11) severe secondary hyperparathyroidism (SHPT) was studied. Additionally, time spent under severe SHPT was also evaluated. Patients with severe SHPT had lower SEVR and higher ejection duration index, indicating higher cardiovascular risk. Lower SEVR was also associated to diastolic blood pressure (r = 0.435, p = 0.049), serum 25-Vitamin-D levels (r = 0.479, p = 0.028) and to more time spent under severe secondary hyperparathyroidism (SHPT), defined as time from PTH > 500pg/ml until parathyroidectomy surgery or end of the study (r = -0.642, p = 0.027). In stepwise multiple regression analysis between SEVR and independent variables, lower SEVR was independently associated to lower serum 25-Vitamin-D levels (p = 0.005), female sex (p = 0.012) and more time spent under severe SHPT (p = 0.001) in a model adjusted for age, serum cholesterol, and blood pressure (adjusted r² = 0.545, p = 0.001). Subendocardial perfusion was lower in patients with BMD, reflecting higher cardiovascular risk in this population. Whether early parathyroidectomy in the course of kidney disease could modify such results still deserves further investigation. Distúrbios do metabolismo ósseo (DMO) e alterações da função vascular contribuem para a elevada mortalidade de pacientes em hemodiálise. A disfunção vascular, um novo marcador de aterosclerose, pode contribuir para este risco. Apesar de associada a aumento de mortalidade na população geral, a avaliação de tal disfunção ainda não foi realizada de modo amplo em pacientes em hemodiálise. Neste estudo transversal, pacientes em hemodiálise foram submetidos à avaliação da vasodilatação mediada por fluxo, razão de viabilidade subendocárdica (RVSE) e índice de duração de ejeção, como estimativas de avaliação dos marcadores de DMO sobre disfunção vascular. Uma coorte pareada com (n = 16) e sem (n = 11) hiperparatireoidismo secundário (HPTS) grave foi estudada. Adicionalmente, o tempo transcorrido do diagnóstico de HPTS grave também foi avaliado. Pacientes com HPTS grave apresentaram menores valores de RVSE e maiores valores de índice de duração de ejeção, apontando maior risco cardiovascular. Baixa RVSE também foi associada à pressão arterial diastólica (r = 0,435, p = 0,049), níveis séricos de 25-Vitamina D (r = 0,479, p = 0,028) e maior tempo transcorrido desde diagnóstico de HPTS grave, definido como tempo em que o paciente permaneceu com valores de paratormônio superiores a 500 pg/ml até realização de cirurgia de paratireoidectomia ou término do estudo (r = -0,642, p = 0,027). Em regressão logística stepwise entre RVSE e variáveis independentes, menor RVSE foi independentemente associado a menores valores de 25-Vitamina D (p = 0,005), sexo feminino (p = 0,012) e maior tempo transcorrido desde diagnóstico de HPTS grave (p = 0,001) em um modelo ajustado para idade, colesterol sérico e pressão arterial (r2 ajustado = 0,545, p = 0,001). A perfusão subendocárdica foi menor em pacientes com DMO, refletindo o maior risco cardiovascular nesta população. Investigações adicionais são necessárias para definir se a paratireoidectomia precoce no curso da doença renal crônica poderia interferir neste risco.

  19. Using archived ITS data to measure the operational benefits of a system-wide adaptive ramp metering system : appendix online 7 : OR\\0x2010217 NB ML speed\\0x2010flow plots.

    DOT National Transportation Integrated Search

    2008-12-01

    The appendix includes various ML speed-flow plots: OR-217 NB, 72nd MP 6.61; OR-217 NB, 99W-EB MP 5.9; OR-217 NB, 99W-WB MP 5.85; OR-217 NB, Greenburg MP 4.65; OR-217 NB, Scholls MP 3.85; OR-217 NB, Denney MP 2.68; OR-217 NB, Allen MP 2.16; OR-217 NB,...

  20. Using archived ITS data to measure the operational benefits of a system-wide adaptive ramp metering system : appendix online 9 : OR\\0x2010217 NB ML flow\\0x2010occupancy plots.

    DOT National Transportation Integrated Search

    2008-12-01

    The appendix includes various ML flow occupancy plots: OR-217 NB, 72nd MP 6.61; OR-217 NB, 99W-EB MP 5.9; OR-217 NB, 99W-WB MP 5.85; OR-217 NB, Greenburg MP 4.65; OR-217 NB, Scholls MP 3.85; OR-217 NB, Denney MP 2.68; OR-217 NB, Allen MP 2.16; OR-217...

  1. Development of a flow controller for long-term sampling of gases and vapors using evacuated canisters.

    PubMed

    Rossner, Alan; Farant, Jean Pierre; Simon, Philippe; Wick, David P

    2002-11-15

    Anthropogenic activities contribute to the release of a wide variety of volatile organic compounds (VOC) into microenvironments. Developing and implementing new air sampling technologies that allow for the characterization of exposures to VOC can be useful for evaluating environmental and health concerns arising from such occurrences. A novel air sampler based on the use of a capillary flow controller connected to evacuated canisters (300 mL, 1 and 6 L) was designed and tested. The capillary tube, used to control the flow of air, is a variation on a sharp-edge orifice flow controller. It essentially controls the velocity of the fluid (air) as a function of the properties of the fluid, tube diameter and length. A model to predict flow rate in this dynamic system was developed. The mathematical model presented here was developed using the Hagen-Poiseuille equation and the ideal gas law to predict flow into the canisters used to sample for long periods of time. The Hagen-Poiseuille equation shows the relationship between flow rate, pressure gradient, capillary resistance, fluid viscosity, capillary length and diameter. The flow rates evaluated were extremely low, ranging from 0.05 to 1 mL min(-1). The model was compared with experimental results and was shown to overestimate the flow rate. Empirical equations were developed to more accurately predict flow for the 300 mL, 1 and 6 L canisters used for sampling periods ranging from several hours to one month. The theoretical and observed flow rates for different capillary geometries were evaluated. Each capillary flow controller geometry that was tested was found to generate very reproducible results, RSD < 2%. Also, the empirical formulas developed to predict flow rate given a specified diameter and capillary length were found to predict flow rate within 6% of the experimental data. The samplers were exposed to a variety of airborne vapors that allowed for comparison of the effectiveness of capillary flow controllers to sorbent samplers and to an online gas chromatograph. The capillary flow controller was found to exceed the performance of the sorbent samplers in this comparison.

  2. A Study on Duration of Effect of Transcutaneous Electrical Nerve Stimulation Therapy on Whole Saliva Flow.

    PubMed

    Bhasin, Neha; Reddy, Sreedevi; Nagarajappa, Anil Kumar; Kakkad, Ankur

    2015-06-01

    Saliva is a complex fluid, whose important role is to maintain the well being of oral cavity. Salivary gland hypofunction or hyposalivation is the condition of having reduced saliva production which leads to the subjective complaint of oral dryness termed xerostomia.(7) Management of xerostomia includes palliative therapy using topical agents or systemic therapy. Electrostimulation to produce saliva was studied in the past and showed moderate promise but never became part of mainstream therapy. Hence, this study was undertaken to evaluate the effect of transcutaneous electrical nerve stimulation (TENS) on whole salivary flow rate in healthy adults and to evaluate how long this effect of TENS lasts on salivary flow. One hundred healthy adult subjects were divided into five age groups with each group containing 20 subjects equally divided into males and females in each group. Unstimulated saliva was collected using a graduated test tube fitted with funnel and quantity was measured. Transcutaneous electrical nerve stimulation unit was activated and stimulated saliva was collected. Saliva was again collected 30 minutes and 24 hours post stimulation. The mean unstimulated whole saliva flow rate for all subjects (n = 100) was 2.60 ml/5 min. During stimulation, it increased to 3.60 ± 0.39 ml/5 min. There was 38.46% increase in salivary flow. Ninety six out of 100 responded positively to TENS therapy. Salivary flow remained increased 30 minutes and 24 hours post stimulation with the values being 3.23 ± 0.41 ml/5 min and 2.69 ± 0.39 ml/5 min respectively. Repeated measures One way analysis of variance (ANOVA) test showed that the difference between these values were statistically significant. Transcutaneous electrical nerve stimulation therapy was effective for stimulation of whole saliva in normal, healthy subjects and its effect retained till 30 minutes and a little up to 24 hours. Transcutaneous electrical nerve stimulation may work best synergistically with other sialagogues and can be used for the management of xerostomia.

  3. Handpiece coolant flow rates and dental cutting.

    PubMed

    von Fraunhofer, J A; Siegel, S C; Feldman, S

    2000-01-01

    High-speed handpieces incorporate water coolant sprays to remove cutting debris and minimize thermal insult to the pulp. Little data exists on optimal coolant flow rates during clinical procedures. This study compared the effect of different coolant flow rates on diamond stone cutting efficiency. Cutting studies were performed on Macor machinable ceramic using a previously developed test regimen--a KaVo high-speed handpiece at a cutting force of 91.5 g (0.9 N). Cutting was performed with round end tapered medium grit diamond stones under cooling water flow rates of 15, 20, 25, 30 and 44 ml/min, with cutting rates determined as the time to transect the 13 mm square cross-section of the Macor bar. Each bur was used for five cuts, with six burs used for each flow rate, for a total of 150 measurements. The data were analyzed by one-way ANOVA with a post hoc Scheffé test. The cutting studies indicated that diamond stone cutting rates increased with higher coolant flow rates over the range of 15-44 ml/min. The data suggest that higher coolant flow rates promote cutting efficiency.

  4. Three-dimensional ultrasound features of the polycystic ovary in Chinese women.

    PubMed

    Lam, P; Raine-Fenning, N; Cheung, L; Haines, C

    2009-08-01

    To quantify the three-dimensional (3D) ultrasound characteristics of ovaries in Chinese women with polycystic ovarian syndrome (PCOS) and to compare these with previous data on a Caucasian cohort with PCOS. 3D pelvic ultrasound was performed in 40 Chinese women with PCOS and 40 controls. Ovarian volume, stromal volume and echogenicity, and antral follicle count (AFC) were measured and ovarian blood flow was quantified using both 3D power Doppler and two-dimensional (2D) pulsed wave Doppler. These data were compared with previously published data on a Caucasian cohort with PCOS. Compared with controls, women with PCOS had a higher AFC (median (range), 15 (11-30) vs. 5.5 (1-10) per ovary, P < 0.01), ovarian volume (12.32 (8.10-16.16) mL vs. 5.64 (2.62-8.81) mL, P < 0.01) and stromal volume (9.74 (6.44-13.56) mL vs. 4.07 (1.52-6.67) mL, P < 0.01) but were comparable in stromal echogenicity and ovarian blood flow as measured by 3D power Doppler or 2D pulsed wave Doppler indices. However, in comparison with a previously reported Caucasian cohort with PCOS, the ovaries of Chinese women with PCOS had a significantly smaller stromal volume (median (range), 9.74 (6.44-13.56) mL vs. 10.79 (5.65-17.12) mL, P < 0.05), were less echogenic as reflected in a lower mean gray value (22.43 (13.13-35.50) vs. 32.36 (19.35-53.71), P < 0.01), and had reduced ovarian blood flow as reflected in a lower flow index (30.19 (23.32-44.88) vs. 33.54 (21.88-51.65), P < 0.05). Based on 3D ultrasound measurements, Chinese women with PCOS have an increased stromal volume compared with controls. However, their stromal volume, echogenicity and vascularity is significantly lower than that in Caucasian women with PCOS. The possible etiology for these differences is discussed.

  5. Autonomic Blockade Reverses Endothelial Dysfunction in Obesity-Associated Hypertension.

    PubMed

    Gamboa, Alfredo; Figueroa, Rocío; Paranjape, Sachin Y; Farley, Ginnie; Diedrich, Andre; Biaggioni, Italo

    2016-10-01

    Impaired nitric oxide (NO) vasodilation (endothelial dysfunction) is associated with obesity and thought to be a factor in the development of hypertension. We previously found that NO synthesis inhibition had similar pressor effects in obese hypertensives compared with healthy control during autonomic blockade, suggesting that impaired NO vasodilation is secondary to sympathetic activation. We tested this hypothesis by determining the effect of autonomic blockade (trimethaphan 4 mg/min IV) on NO-mediated vasodilation (increase in forearm blood flow to intrabrachial acetylcholine) compared with endothelial-independent vasodilation (intrabrachial sodium nitroprusside) in obese hypertensive subjects (30

  6. Specific pathogen-free status alters immunophenotype in rhesus macaques: implications for the study of simian immunodeficiency virus.

    PubMed

    Santos, Rosemary V; Lin, Kuei-Chin; Mansfield, Keith; Wachtman, Lynn M

    2011-10-01

    The repertoire of viruses to which research primates are exposed, even in the absence of clinical disease, may contribute to experimental confounding. In this study we examined whether standard specific pathogen-free (SPF) rhesus macaques exposed to a wider spectrum of enzootic viruses and expanded SPF macaques derived to exclude a greater number of viral agents would display alterations in immune activation or immune cell populations. Given the impact of immunophenotype on human immunodeficiency virus (HIV) progression and the importance of the simian immunodeficiency virus (SIV) model for the study of HIV pathogenesis, we elected to additionally examine the impact of SPF status on the capacity of peripheral blood mononuclear cells (PBMCs) to support SIV replication. The expanded SPF group displayed significant immune alterations including increased serum interleukin (IL)-15 and a greater in vitro elaboration of GM-CSF, IL1ra, VEGF, IL-10, IL12/23, and MIP-1b. Consistent with reduced viral antigenic exposure in expanded SPF macaques, decreased CD4(+) and CD8(+) transitional and effector memory (T(EM)) cell populations were observed. Expanded SPF PBMC cultures also demonstrated an increased peak (192.61 ng/ml p27) and area under the curve in in vitro SIV production (1968.64 ng/ml p27) when compared to standard SPF macaques (99.32 ng/ml p27; p=0.03 and 915.17 ng/ml p27; p=0.03, respectively). In vitro SIV replication did not correlate with CD4(+) T(EM) cell counts but was highly correlated with serum IL-15 in the subset of animals examined. Findings suggest that an altered immunophenotype associated with the maintenance of primates under differing levels of bioexclusion has the potential to impact the outcome of SIV studies and models for which the measurement of immunologic endpoints is critical.

  7. Subwavelength prestressed microcantilevers based metamaterials for efficient manipulation of terahertz waves

    DTIC Science & Technology

    2015-07-01

    for the fluid flow controlled MEMS metamaterial with PDMS chamber. (b)-(d) shows the cantilever deformation with respect to increasing fluid flow...Firstly the metamaterial was integrated with a polydimethylsiloxane fluidic channel and the injection flow rate was varied from 0 to 5 ml/min

  8. Lack of age-specific influence on leg blood flow during incremental calf plantar-flexion exercise in men and women.

    PubMed

    Reilly, Heather; Lane, Louise M; Egaña, Mikel

    2018-05-01

    Age-related exercising leg blood flow (LBF) responses during dynamic knee-extension exercise and forearm blood flow responses during handgrip exercise are preserved in normally active men but attenuated in activity-matched women. We explored whether these age- and sex-specific effects are also apparent during isometric calf plantar-flexion incremental exercise. Normally active young men (YM, n = 15, 24 ± 2 years), young women (YW, n = 8, 22 ± 1 years), older men (OM, n = 13, 70 ± 7 years) and older women (OW, n = 10, 64 ± 7 years) were tested. LBF was measured between contractions using venous occlusion plethysmography. Peak force obtained was higher (P < 0.05) in men compared with women and in young compared with older individuals. However, peak LBF (YM; 971 ± 328 ml min -1 , OM; 985 ± 504 ml min -1 , YW; 844 ± 366 ml min -1 , OW; 960 ± 244 ml min -1 ) and peak leg vascular conductance [LVC = LBF/(MAP + hydrostatic pressure)] responses (YM; 6.0 ± 1.8 ml min -1  mmHg -1 , OM; 5.5 ± 2.8 ml min -1  mmHg -1 , YW; 5.3 ± 2.1 ml min -1  mmHg -1 , OW; 5.5 ± 1.6 ml min -1 mmHg -1 ) were similar among the four groups. Furthermore, the hyperaemic (YM; 8.8 ± 3.7 ml min -1  %F peak -1 OM; 8.3 ± 5.4 ml min -1  %F peak -1 , YW; 8.2 ± 3.5 ml min -1  %F peak -1 , OW; 9.6 ± 2.2 ml min -1  %F peak -1 ) and vasodilatory responses (YM; 0.053 ± 0.020 ml min -1  mmHg -1  %F peak -1 , OM; 0.048 ± 0.028 ml min -1  mmHg -1  %F peak -1 , YW; 0.051 ± 0.019 ml min -1  mmHg -1  %F peak -1 , OW; 0.055 ± 0.014 ml min -1  mmHg -1  %F peak -1 ) were not different among the four groups. These results were accompanied by similar resting LBF responses among groups and were not affected when data were normalised to estimated leg muscle mass. Our results demonstrate that exercising LBF responses during isometric incremental calf muscle exercise are preserved in older men and women, suggesting that the previously observed age-related attenuations in leg and forearm hyperaemia among women may be muscle-group specific.

  9. Gas exchange efficiency of an oxygenator with integrated pulsatile displacement blood pump for neonatal patients.

    PubMed

    Schlanstein, Peter C; Borchardt, Ralf; Mager, Ilona; Schmitz-Rode, Thomas; Steinseifer, Ulrich; Arens, Jutta

    2014-01-01

    Oxygenators have been used in neonatal extracorporeal membrane oxygenation (ECMO) since the 1970s. The need to develop a more effective oxygenator for this patient cohort exists due to their size and blood volume limitations. This study sought to validate the next design iteration of a novel oxygenator for neonatal ECMO with an integrated pulsatile displacement pump, thereby superseding an additional blood pump. Pulsating blood flow within the oxygenator is generated by synchronized active air flow expansion and contraction of integrated silicone pump tubes and hose pinching valves located at the oxygenator inlet and outlet. The current redesign improved upon previous prototypes by optimizing silicone pump tube distribution within the oxygenator fiber bundle; introduction of an oval shaped inner fiber bundle core, and housing; and a higher fiber packing density, all of which in combination reduced the priming volume by about 50% (50 to 27 mL and 41 to 20 mL, respectively). Gas exchange efficiency was tested for two new oxygenators manufactured with different fiber materials: one with coating and one with smaller pore size, both capable of long-term use (OXYPLUS® and CELGARD®). Results demonstrated that the oxygen transfer for both oxygenators was 5.3-24.7 mlO2/min for blood flow ranges of 100-500 mlblood/min. Carbon dioxide transfer for both oxygenators was 3.7-26.3 mlCO2/min for the same blood flow range. These preliminary results validated the oxygenator redesign by demonstrating an increase in packing density and thus in gas transfer, an increase in pumping capacity and a reduction in priming volume.

  10. Comparative study of the concentration of salivary and blood glucose in type 2 diabetic patients.

    PubMed

    Vasconcelos, Ana Carolina U; Soares, Maria Sueli M; Almeida, Paulo C; Soares, Teresa C

    2010-06-01

    The objective of the present study was to comparatively evaluate the concentrations of blood and salivary glucose as well as salivary flow and xerostomia in type 2 diabetic and non-diabetic patients. The mean salivary glucose level in diabetic patients was 14.03 +/-16.76 mg/dl and 6.35 +/- 6.02 mg/dl (P = 0.036) in the control group. The mean capillary blood glucose level in diabetic patients was 213 +/- 88 mg/dl, while that in non-diabetic patients was 99 +/- 14 mg/dl (P = 0.000). The mean value for resting salivary flow was 0.21 +/- 0.16 ml/min in diabetic patients and 0.33 +/- 0.20 ml/min in the control group (P = 0.002). The stimulated salivary flow was lower in the group of diabetic patients, with a mean of 0.63 +/- 0.43 ml/min, whereas the control group showed a mean of 1.20 +/- 0.70 ml/min (P = 0.000). Of the diabetic patients, 45% exhibited hyposalivation, in contrast to 2.5% of the non-diabetic patients (P = 0.000). Xerostomia was reported in 12.5% of diabetic patients and 5% of non-diabetic patients (P = 0.23). We can conclude that salivary glucose concentration was significantly higher in the experimental group and that there was no correlation between salivary and blood glucose concentrations in diabetic patients. The total salivary flow was significantly reduced in diabetic patients and there was no significant difference as to the presence of xerostomia in both groups.

  11. Gravity currents in rotating channels. Part 1. Steady-state theory

    NASA Astrophysics Data System (ADS)

    Hacker, J. N.; Linden, P. F.

    2002-04-01

    A theory is developed for the speed and structure of steady-state non-dissipative gravity currents in rotating channels. The theory is an extension of that of Benjamin (1968) for non-rotating gravity currents, and in a similar way makes use of the steady-state and perfect-fluid (incompressible, inviscid and immiscible) approximations, and supposes the existence of a hydrostatic ‘control point’ in the current some distance away from the nose. The model allows for fully non-hydrostatic and ageostrophic motion in a control volume V ahead of the control point, with the solution being determined by the requirements, consistent with the perfect-fluid approximation, of energy and momentum conservation in V, as expressed by Bernoulli's theorem and a generalized flow-force balance. The governing parameter in the problem, which expresses the strength of the background rotation, is the ratio W = B/R, where B is the channel width and R = (g[prime prime or minute]H)1/2/f is the internal Rossby radius of deformation based on the total depth of the ambient fluid H. Analytic solutions are determined for the particular case of zero front-relative flow within the gravity current. For each value of W there is a unique non-dissipative two-layer solution, and a non-dissipative one-layer solution which is specified by the value of the wall-depth h0. In the two-layer case, the non-dimensional propagation speed c = cf(g[prime prime or minute]H)[minus sign]1/2 increases smoothly from the non-rotating value of 0.5 as W increases, asymptoting to unity for W [rightward arrow] [infty infinity]. The gravity current separates from the left-hand wall of the channel at W = 0.67 and thereafter has decreasing width. The depth of the current at the right-hand wall, h0, increases, reaching the full depth at W = 1.90, after which point the interface outcrops on both the upper and lower boundaries, with the distance over which the interface slopes being 0.881R. In the one-layer case, the wall-depth based propagation speed Froude number c0 = cf(g[prime prime or minute]h0)[minus sign]1/2 = 21/2, as in the non-rotating one-layer case. The current separates from the left-hand wall of the channel at W0 [identical with] B/R0 = 2[minus sign]1/2, and thereafter has width 2[minus sign]1/2R0, where R0 = (g[prime prime or minute]h0)1/2/f is the wall-depth based deformation radius.

  12. Lymphatic Regeneration within Porous VEGF-C Hydrogels for Secondary Lymphedema

    DTIC Science & Technology

    2006-01-01

    19a. NAME OF RESPONSIBLE PERSON USAMRMC a. REPORT U b . ABSTRACT U c. THIS PAGE U UU 16 19b. TELEPHONE NUMBER (include area code...0.22 μg/ml, B ) Ang-2 concentration of 0.67 μg/ml, C) Ang-2 concentration of and 2 μg/ml. With these initial results we determined that the...A) Normal lymphatic flow. B ) Obliteration of tail lymphatics with subsequent lymphedema formation. C) Lymphangiogenesis by transplantation

  13. Head-down-tilt bed rest alters forearm vasodilator and vasoconstrictor responses

    NASA Technical Reports Server (NTRS)

    Shoemaker, J. K.; Hogeman, C. S.; Silber, D. H.; Gray, K.; Herr, M.; Sinoway, L. I.

    1998-01-01

    To test the hypothesis that head-down-tilt bed rest (HDBR) for 14 days alters vascular reactivity to vasodilatory and vasoconstrictor stimuli, the reactive hyperemic forearm blood flow (RHBF, measured by venous occlusion plethysmography) and mean arterial pressure (MAP, measured by Finapres) responses after 10 min of circulatory arrest were measured in a control trial (n = 20) and when sympathetic discharge was increased by a cold pressor test (RHBF + cold pressor test; n = 10). Vascular conductance (VC) was calculated (VC = RHBF/MAP). In the control trial, peak RHBF at 5 s after circulatory arrest (34.1 +/- 2.5 vs. 48.9 +/- 4.3 ml . 100 ml-1 . min-1) and VC (0.34 +/- 0.02 vs. 0.53 +/- 0.05 ml . 100 ml-1 . min-1 . mmHg-1) were reduced in the post- compared with the pre-HDBR tests (P < 0. 05). Total excess RHBF over 3 min was diminished in the post- compared with the pre-HDBR trial (84.8 vs. 117 ml/100 ml, P < 0.002). The ability of the cold pressor test to lower forearm blood flow was less in the post- than in the pre-HDBR test (P < 0.05), despite similar increases in MAP. These data suggest that regulation of vascular dilation and the interaction between dilatory and constrictor influences were altered with bed rest.

  14. Simultaneous trace multielement determination by ICP-OES after solid phase extraction with modified octadecyl silica gel.

    PubMed

    Karbasi, Mohamad-Hadi; Jahanparast, Babak; Shamsipur, Mojtaba; Hassan, Jalal

    2009-10-15

    Multielement simultaneous determination of 35 trace elements in environmental samples was carried out by inductively coupled plasma emission spectrometry (ICP-OES) after preconcentration with octadecyl silicagel, modified with aurin tricarboxylic acid (Aluminon). Optimal experimental conditions including pH of sample solution, sample volume, sample and eluent flow rate, type, concentration and volume of eluent and foreign ions effect were investigated and established. Trace element ions in aqueous solution were quantitatively adsorbed onto octadecyl silicagel modified with aurin tricarboxylic acid at pH 8.0 with a flow rate of 11.0 mL min(-1). The adsorbed element ions were eluted with 3-5 mL of 0.5 mol L(-1) HNO(3) at a flow rate of 10.0 mL min(-1) and analyzed by ICP-OES simultaneously. The proposed method has at least preconcentration factor of 100 in water samples, which results high sensitive detection of ultra-trace and trace analysis. The present methodology gave recoveries better than 70% and RSD less than 16%.

  15. CytometryML and other data formats

    NASA Astrophysics Data System (ADS)

    Leif, Robert C.

    2006-02-01

    Cytology automation and research will be enhanced by the creation of a common data format. This data format would provide the pathology and research communities with a uniform way for annotating and exchanging images, flow cytometry, and associated data. This specification and/or standard will include descriptions of the acquisition device, staining, the binary representations of the image and list-mode data, the measurements derived from the image and/or the list-mode data, and descriptors for clinical/pathology and research. An international, vendor-supported, non-proprietary specification will allow pathologists, researchers, and companies to develop and use image capture/analysis software, as well as list-mode analysis software, without worrying about incompatibilities between proprietary vendor formats. Presently, efforts to create specifications and/or descriptions of these formats include the Laboratory Digital Imaging Project (LDIP) Data Exchange Specification; extensions to the Digital Imaging and Communications in Medicine (DICOM); Open Microscopy Environment (OME); Flowcyt, an extension to the present Flow Cytometry Standard (FCS); and CytometryML. The feasibility of creating a common data specification for digital microscopy and flow cytometry in a manner consistent with its use for medical devices and interoperability with both hospital information and picture archiving systems has been demonstrated by the creation of the CytometryML schemas. The feasibility of creating a software system for digital microscopy has been demonstrated by the OME. CytometryML consists of schemas that describe instruments and their measurements. These instruments include digital microscopes and flow cytometers. Optical components including the instruments' excitation and emission parts are described. The description of the measurements made by these instruments includes the tagged molecule, data acquisition subsystem, and the format of the list-mode and/or image data. Many of the CytometryML data-types are based on the Digital Imaging and Communications in Medicine (DICOM). Binary files for images and list-mode data have been created and read.

  16. Electromagnetic Pumps for Conductive-Propellant Feed Systems

    NASA Technical Reports Server (NTRS)

    Markusic, T. E.; Polzin, K. A.

    2005-01-01

    There has been a recent, renewed interest in high-power electric thrusters for application in nuclear-electric propulsion systems. Two of the most promising thrusters utilize liquid metal propellants: the lithium-fed magnetoplasmadynamic thruster and the bismuth-fed Hall thruster. An important element of part of the maturation of these thrusters will be the development of compact, reliable conductive-propellant feed system components. In the present paper we provide design considerations and experimental calibration data for electromagnetic (EM) pumps. The role of an electromagnetic pump in a liquid metal feed system is to establish a pressure gradient between the propellant reservoir and the thruster - to establish the requisite mass flow rate. While EM pumps have previously been used to a limited extent in nuclear reactor cooling loops, they have never been implemented in electric propulsion (EP) systems. The potential benefit of using EM pumps for EP are reliability (no moving parts) and the ability to precisely meter the propellant flow rate. We have constructed and tested EM pumps that use gallium, lithium, and bismuth propellants. Design details, test results (pressure developed versus current), and material compatibility issues are reported. It is concluded that EM pumps are a viable technology for application in both laboratory and flight EP conductive-propellant feed systems.

  17. Orion Service Module Umbilical (OSMU) Installation on Mobile Launcher (ML)

    NASA Image and Video Library

    2017-03-13

    Cranes and rigging are being used to lift the bracket for the Orion Service Module Umbilical (OSMU) up for installation on the mobile launcher tower. The tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  18. Streptavidin-functionalized capillary immune microreactor for highly efficient chemiluminescent immunoassay.

    PubMed

    Yang, Zhanjun; Zong, Chen; Ju, Huangxian; Yan, Feng

    2011-11-07

    A streptavidin functionalized capillary immune microreactor was designed for highly efficient flow-through chemiluminescent (CL) immunoassay. The functionalized capillary could be used as both a support for highly efficient immobilization of antibody and a flow cell for flow-through immunoassay. The functionalized inner wall and the capture process were characterized using scanning electron microscopy. Compared to conventional packed tube or thin-layer cell immunoreactor, the proposed microreactor showed remarkable properties such as lower cost, simpler fabrication, better practicality and wider dynamic range for fast CL immunoassay with good reproducibility and stability. Using α-fetoprotein as model analyte, the highly efficient CL flow-through immunoassay system showed a linear range of 3 orders of magnitude from 0.5 to 200 ng mL(-1) and a low detection limit of 0.1 ng mL(-1). The capillary immune microreactor could make up the shortcoming of conventional CL immunoreactors and provided a promising alternative for highly efficient flow-injection immunoassay. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Arduino control of a pulsatile flow rig.

    PubMed

    Drost, S; de Kruif, B J; Newport, D

    2018-01-01

    This note describes the design and testing of a programmable pulsatile flow pump using an Arduino micro-controller. The goal of this work is to build a compact and affordable system that can relatively easily be programmed to generate physiological waveforms. The system described here was designed to be used in an in-vitro set-up for vascular access hemodynamics research, and hence incorporates a gear pump that delivers a mean flow of 900 ml/min in a test flow loop, and a peak flow of 1106 ml/min. After a number of simple identification experiments to assess the dynamic behaviour of the system, a feed-forward control routine was implemented. The resulting system was shown to be able to produce the targeted representative waveform with less than 3.6% error. Finally, we outline how to further increase the accuracy of the system, and how to adapt it to specific user needs. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. Comparison in partition efficiency of protein separation between four different tubing modifications in spiral high-speed countercurrent chromatography

    PubMed Central

    Ito, Yoichiro; Clary, Robert

    2016-01-01

    High-speed countercurrent chromatography with a spiral tube assembly can retain a satisfactory amount of stationary phase of polymer phase systems used for protein separation. In order to improve the partition efficiency a simple tool to modify the tubing shapes was fabricated, and the following four different tubing modifications were made: intermittently pressed at 10 mm width, flat, flat-wave, and flat-twist. Partition efficiencies of the separation column made from these modified tubing were examined in protein separation with an aqueous-aqueous polymer phase system at flow rates of 1–2 ml/min under 800 rpm. The results indicated that the column with all modified tubing improved the partition efficiency at a flow rate of 1 ml/min, but at a higher flow rate of 2 ml/min the columns made of flattened tubing showed lowered partition efficiency apparently due to the loss of the retained stationary phase. Among all the modified columns, the column with intermittently pressed tubing gave the best peak resolution. It may be concluded that the intermittently pressed and flat-twist improve the partition efficiency in a semi-preparative separation while other modified tubing of flat and flat-wave configurations may be used for analytical separations with a low flow rate. PMID:27790621

  1. Comparison in partition efficiency of protein separation between four different tubing modifications in spiral high-speed countercurrent chromatography.

    PubMed

    Ito, Yoichiro; Clary, Robert

    2016-12-01

    High-speed countercurrent chromatography with a spiral tube assembly can retain a satisfactory amount of stationary phase of polymer phase systems used for protein separation. In order to improve the partition efficiency a simple tool to modify the tubing shapes was fabricated, and the following four different tubing modifications were made: intermittently pressed at 10 mm width, flat, flat-wave, and flat-twist. Partition efficiencies of the separation column made from these modified tubing were examined in protein separation with an aqueous-aqueous polymer phase system at flow rates of 1-2 ml/min under 800 rpm. The results indicated that the column with all modified tubing improved the partition efficiency at a flow rate of 1 ml/min, but at a higher flow rate of 2 ml/min the columns made of flattened tubing showed lowered partition efficiency apparently due to the loss of the retained stationary phase. Among all the modified columns, the column with intermittently pressed tubing gave the best peak resolution. It may be concluded that the intermittently pressed and flat-twist improve the partition efficiency in a semi-preparative separation while other modified tubing of flat and flat-wave configurations may be used for analytical separations with a low flow rate.

  2. [Clinical evaluation of Engström's electrically controlled ELSA for low flow closed circuit anesthesia].

    PubMed

    Igarashi, M; Nakae, Y; Ichimiya, N; Watanabe, H; Iwasaki, H; Namiki, A

    1993-02-01

    Many anesthesiologists are now interested in low flow, closed circuit anesthesia from an economical and environmental point of view. In order to evaluate clinically a newly developed electronically controlled anesthesia machine Engström's ELSA, we compared low flow, closed circuit anesthesia on 38 ASA I-II patients using ELSA, with high flow anesthesia on 12 ASA I-II patients using a conventional anesthesia machine. The results were as follows; 1. We could perform safe and economical low flow, closed circuit anesthesia using ELSA's injection vaporizer and accurate monitoring devices for O2, N2O, CO2 and concentrations of various volatile anesthetic agents. 2. Under low flow anesthesia, isoflurane consumption was 5.3 +/- 1.1 ml.h-1 x Vol.%-1 (mean +/- SE) with ELSA, which is about one fourth of the high flow anesthesia consumption (22.6 +/- 2.1 ml.h-1 x Vol.%-1 (mean +/- SE). 3. Low flow closed circuit anesthesia could maintain significantly higher temperature and humidity compared with high flow anesthesia. 4. Under low flow anesthesia of more than 7hrs, color of soda lime becomes blue, but this does not affect FIO2 nor PaCO2, and the method is clinically safe for patients.

  3. Enzymatic amplification of a flow-injected thermometric enzyme-linked immunoassay for human insulin.

    PubMed

    Mecklenburg, M; Lindbladh, C; Li, H; Mosbach, K; Danielsson, B

    1993-08-01

    A flow-injected thermometric enzyme linked immunoassay for human insulin which employs the lactate dehydrogenase/lactate oxidase (LDH/LOD) substrate recycling system for signal amplification is described. The system is composed of two columns, an immunosorbent column containing immobilized anti-insulin antibodies for sensing and a recycling column containing immobilized LDH/LOD/Catalase for detection. The effect of flow rates, conjugate concentrations, and chromatographic support material upon the sensitivity of the assay are investigated. The assay has a detection limit of 0.025 microgram/ml and a linear range from 0.05 to 2 micrograms/ml. This corresponds to a 10-fold increase in sensitivity over the unamplified system. A recombinant human insulin-proinsulin conjugate was also tested. The results show that enzymatic amplification can be employed to increase the sensitivity and reproducibility of flow injection assay-based biosensors. The implications of these results upon on-line analysis are discussed.

  4. A reflectance flow-through thionine sol-gel sensor for the determination of Se(IV).

    PubMed

    Carvalhido, Joana A E; Almeida, Agostinho A; Araújo, Alberto N; Montenegro, Maria C B S M

    2010-01-01

    In this work, a reversible sensor to assess the total Se(IV) content in samples is described. Pre-activated glass slides were spin-coated with 100 microL of a 20-h aged sol-gel mixture of 1 mL of tetramethoxysilane, 305 microL of 50 mmol L(-1) HCl and 2.0 mg of thionine. The flow-cell consisted of one of those slides as a window, and was filled with beads of a polystyrene anionic exchange resin to retain Se(IV) in the form of selenite ions. A reflectance transduction scheme at a wavelength of 596 nm was adopted. The cell was coupled to a multicommutation flow system where a programmed volume of a sample solution and 373 microL of 0.4 mmol L(-1) iodide in a 1.6 mol L(-1) HCl solution were sequentially inserted into the cell. The iodine produced from the reaction of retained Se(IV) with iodide bleached the blue color of thionine. Considering a sample volume of 2.30 mL, with which the preconcentration step was minimized, a linear dynamic working range between 1.5 to 20 microg mL(-1) and a detection limit of 0.29 microg mL(-1) were obtained. The sensor enabled us to perform approximately 200 assays, and provided results similar to those of electrothermal atomic absorption spectrometry.

  5. Vitamin E-coated membrane dialyzer and beta2-microglobulin removal.

    PubMed

    Mandolfo, S; Bucci, R; Imbasciati, E

    2003-12-01

    This study was designed to test the removal of beta2-microglobulin (beta2M) in a vitamin E-modified membrane. We investigated in vivo the dialyzer (Excebrane, series EE, 1.8 m2) with respect to hydraulic permeability (Kuf), maximum ultrafiltration rate (UF max), sieving coefficient (Sc), and solute clearances in hemodialysis (HD) and in soft hemodiafiltration (HDF). Kuf was 18.4 ml/h/mmHg, UF max was 75 ml/min, and Sc for beta2M was 0.45. Clearance values at 400 ml/min of Qb in HD were 258 ml/min for urea, 201 ml/min for creatinine, and 135 ml/min for phosphate. In soft HDF, clearances were slightly higher. beta2M clearance was 26 ml/min in HD and 43 ml/min in soft HDF. In conclusion, Excebrane (series EE) procures a soft HDF with an amount of substitution fluid in post dilution mode of over 60 ml/min. Remarkable small solute clearances were obtained when the blood flow was raised to 400 ml/min. A significant reduction of beta2M is demonstrated by HDF.

  6. Cold plasma inactivates Salmonella Stanley and Escherichia coli O157:H7 inoculated on golden delicious apples.

    PubMed

    Niemira, Brendan A; Sites, Joseph

    2008-07-01

    Cold plasma generated in a gliding arc was applied to outbreak strains of Escherichia coli O157:H7 and Salmonella Stanley on agar plates and inoculated onto the surfaces of Golden Delicious apples. This novel sanitizing technology inactivated both pathogens on agar plates, with higher flow rate (40 liters/min) observed to be more efficacious than were lower flow rates (20 liters/min), irrespective of treatment time (1 or 2 min). Golden Delicious apples were treated with various flow rates (10, 20, 30, or 40 liters/min) of cold plasma for various times (1, 2, or 3 min), applied to dried spot inoculations. All treatments resulted in significant (P < 0.05) reductions from the untreated control, with 40 liters/min more effective than were lower flow rates. Inactivation of Salmonella Stanley followed a time-dependent reduction for all flow rates. Reductions after 3 min ranged from 2.9 to 3.7 log CFU/ml, close to the limit of detection. For E. coli O157:H7, 40 liters/min gave similar reductions for all treatment times, 3.4 to 3.6 log CFU/ml. At lower flow rates, inactivation was related to exposure time, with 3 min resulting in reductions of 2.6 to 3 log CFU/ml. Temperature increase of the treated apples was related to exposure time for all flow rates. The maximum temperature of any plasma-treated apple was 50.8 degrees C (28 degrees C above ambient), after 20 liters/min for 3 min, indicating that antimicrobial effects were not the result of heat. These results indicate that cold plasma is a nonthermal process that can effectively reduce human pathogens inoculated onto fresh produce.

  7. [Low flow anaesthesia with isoflurane in the dog].

    PubMed

    Kramer, Sabine; Alyakine, Hassan; Nolte, Ingo

    2005-01-01

    The aim of the present study was to compare the safety of two low flow (LF) regimes [fresh gas flow (FGF) 20 ml/kg/min (group 2) and 14 ml/kg/min (group 3)] with the high flow (HF) technique (FGF 50 ml/kg/min; group 1) of isoflurane anaesthesia. Data were gathered from ninety dogs assigned for surgery under general anaesthesia with an expected duration of 75 minutes or longer. All dogs had an anaesthetic induction with 0,6 mg/kg I-methadone (maximum 25 mg) and 1 mg/kg diazepam (maximum 25 mg) i.v. Anaesthesia was maintained with isoflurane in a mixture of 50% O2 and 50% N2O as carrier gases, with controlled ventilation. The Monitoring included electrocardiogramm, body temperature, the temperature of in- and exspired gases, arterial oxygen saturation, arterial blood pressure as well as a continuous monitoring of inhaled and exhaled gas concentrations (O2, N2O, CO2, isoflurane). The consumption of isoflurane and carrier gases as well as the recovery times were evaluated for the three groups. The inspired oxygen concentrations always ranged above the minimum value of 30 Vol.-% during low flow anaesthesia. The arterial oxygen saturation ranged between 92-98%, the end tidal concentration of CO2 between 35 and 45 mmHg. Heart rate and arterial blood pressure were within normal limits. Recovery time was significantly shorter after LF than after HF anaesthesia. The highest decrease in body temperature occurred in the HF group 1 because of a significantly lower anaesthetic gas temperature. Despite this, LF anaesthesia resulted in a reduced consumption of carrier gases and volatiles. In conclusion, low flow anaesthesia with isoflurane is a safe technique and offers substantial economic advantages over high flow techniques and is moreover better tolerated by the patients.

  8. Low cerebral blood flow is a risk factor for severe intraventricular haemorrhage

    PubMed Central

    Meek, J.; Tyszczuk, L.; Elwell, C.; Wyatt, J

    1999-01-01

    AIMS—To investigate the relation between cerebral blood flow on the first day of postnatal life and the severity of any subsequent germinal matrix haemorrhage-intraventricular haemorrhage (GMH-IVH).
METHODS—Cerebral blood flow was measured in 24 babies during the first 24 hours of life using near infrared spectroscopy. Repeated cerebral ultrasound examination was performed to define the maximum extent of GMH-IVH. Infants were classified as: normal scan, minor periventricular haemorrhage (haemorrhage that resolved), or severe GMH-IVH (haemorrhage distending the ventricles, that progressed to either post haemorrhagic dilatation or porencephalic cyst formation).
RESULTS—Cerebral blood flow was significantly lower in the infants with GMH-IVH (median 7.0 ml/100 g/min) than those without haemorrhage (median 12.2 ml/100 g/min), despite no difference in carbon dioxide tension and a higher mean arterial blood pressure. On subgroup analysis, those infants with severe GMH-IVH had the lowest cerebral blood flow.
CONCLUSION—A low cerebral blood flow on the first day of life is associated with the subsequent development of severe intraventricular haemorrhage.

 PMID:10375356

  9. Beat-by-beat stroke volume assessment by pulsed Doppler in upright and supine exercise

    NASA Technical Reports Server (NTRS)

    Loeppky, J. A.; Greene, E. R.; Hoekenga, D. E.; Caprihan, A.; Luft, U. C.

    1981-01-01

    The instantaneous stroke volume (SV) and cardiac output (Q) in eight male subjects during steady-state supine (S) and upright (U) exercises at 300 kpm/min is assessed by a 3.0-MHz pulsed Doppler echocardiograph. The mean transients in heart rate (HR), SV, and Q for each posture were determined and the center-line blood velocities obtained in the ascending aorta. Results show that the mean supine values for SV and Q at rest and exercise were 111 ml and 6.4 l/min and 112 ml and 9.7 l/min, respectively. The corresponding results for U were 76 ml and 5.6 l/min and 92 ml and 8.4 l/min, respectively. The values compare favorably with previous studies utilizing invasive procedures. The transient response of Q following the onset of exercise in U was about twice as fast as in S because of the rapid and almost immediate upsurge in SV. The faster rise in aortic flow in U with exercise represented and additional volume (184 ml) of blood passing through the aorta compared with S in the first 20 exercises. It is suggested that the rapid mobilization of pooled venous blood from the leg veins during U was responsible for the increased blood flow.

  10. Mechanical performance comparison between RotaFlow and CentriMag centrifugal blood pumps in an adult ECLS model.

    PubMed

    Yulong Guan; Xiaowei Su; McCoach, Robert; Kunselman, Allen; El-Banayosy, Aly; Undar, Akif

    2010-03-01

    Centrifugal blood pumps have been widely adopted in conventional adult cardiopulmonary bypass and circulatory assist procedures. Different brands of centrifugal blood pumps incorporate distinct designs which affect pump performance. In this adult extracorporeal life support (ECLS) model, the performances of two brands of centrifugal blood pump (RotaFlow blood pump and CentriMag blood pump) were compared. The simulated adult ECLS circuit used in this study included a centrifugal blood pump, Quadrox D membrane oxygenator and Sorin adult ECLS tubing package. A Sorin Cardiovascular(R) VVR(R) 4000i venous reservoir (Sorin S.p.A., Milan, Italy) with a Hoffman clamp served as a pseudo-patient. The circuit was primed with 900ml heparinized human packed red blood cells and 300ml lactated Ringer's solution (total volume 1200 ml, corrected hematocrit 40%). Trials were conducted at normothermia (36 degrees C). Performance, including circuit pressure and flow rate, was measured for every setting analyzed. The shut-off pressure of the RotaFlow was higher than the CentriMag at all measurement points given the same rotation speed (p < 0.0001). The shut-off pressure differential between the two centrifugal blood pumps was significant and increased given higher rotation speeds (p < 0.0001). The RotaFlow blood pump has higher maximal flow rate (9.08 +/- 0.01L/min) compared with the CentriMag blood pump (8.37 +/- 0.02L/min) (p < 0.0001). The blood flow rate differential between the two pumps when measured at the same revolutions per minute (RPM) ranged from 1.64L/min to 1.73L/min. The results obtained in this experiment demonstrate that the RotaFlow has a higher shut-off pressure (less retrograde flow) and maximal blood flow rate than the CentriMag blood pump. Findings support the conclusion that the RotaFlow disposable pump head has a better mechanical performance than the CentriMag. In addition, the RotaFlow disposable pump is 20-30 times less expensive than the CentriMag.

  11. [Impact of low level laser therapy on skin blood flow].

    PubMed

    Podogrodzki, Jacek; Lebiedowski, Michał; Szalecki, Mieczysław; Kępa, Izabela; Syczewska, Małgorzata; Jóźwiak, Sergiusz

    2016-01-01

    The aim of this study was to objectively assess the impact of low level laser therapy on skin blood flow, in terms of two of its components - the flow and trophic and therapeutic effect. Nineteen children aged 3-15 years have been included in the study (seven boys and twelve girls) with a diagnosis of meningomyelocele in the lumbosacral area. In nine of them (47.3%) bedsores were found in the area of paresis location. Studies of skin blood flow were performed using xenon 133 clearance in the Department of Nuclear Medicine of the Children's Memorial Health Institute. Xenon 133 radioisotope in saline with intrinsic activity 74 MBq in 1 ml was used as the marker. Laser application was performed immediately prior to the application of the marker with a tag shower 60 mW probe, emitting 680 nm red light with surface power density of 0.5 J/cm2. Within the tested children the laser application resulted in a significantly increased skin blood flow. Average results in tested group before LLLT are 7.47 ml/100 g/min, after LLLT 11.08 ml/100 g/min. 1. LLLT significantly increases the perfusion of the skin. 2. The effect of the increased perfusion as the result of laserotherapy in the most evident in children with skin trophic abnormalities. 3. Results confirmed by clinical observation indicate, that perfusion increase in relation to LLLT takes place with participation of trophic component of skin blood circulation.

  12. Oral antioxidants improve leg blood flow during exercise in patients with chronic obstructive pulmonary disease

    PubMed Central

    Rossman, Matthew J.; Trinity, Joel D.; Garten, Ryan S.; Ives, Stephen J.; Conklin, Jamie D.; Barrett-O'Keefe, Zachary; Witman, Melissa A. H.; Bledsoe, Amber D.; Morgan, David E.; Runnels, Sean; Reese, Van R.; Zhao, Jia; Amann, Markus; Wray, D. Walter

    2015-01-01

    The consequence of elevated oxidative stress on exercising skeletal muscle blood flow as well as the transport and utilization of O2 in patients with chronic obstructive pulmonary disease (COPD) is not well understood. The present study examined the impact of an oral antioxidant cocktail (AOC) on leg blood flow (LBF) and O2 consumption during dynamic exercise in 16 patients with COPD and 16 healthy subjects. Subjects performed submaximal (3, 6, and 9 W) single-leg knee extensor exercise while LBF (Doppler ultrasound), mean arterial blood pressure, leg vascular conductance, arterial O2 saturation, leg arterial-venous O2 difference, and leg O2 consumption (direct Fick) were evaluated under control conditions and after AOC administration. AOC administration increased LBF (3 W: 1,604 ± 100 vs. 1,798 ± 128 ml/min, 6 W: 1,832 ± 109 vs. 1,992 ± 120 ml/min, and 9W: 2,035 ± 114 vs. 2,187 ± 136 ml/min, P < 0.05, control vs. AOC, respectively), leg vascular conductance, and leg O2 consumption (3 W: 173 ± 12 vs. 210 ± 15 ml O2/min, 6 W: 217 ± 14 vs. 237 ± 15 ml O2/min, and 9 W: 244 ± 16 vs 260 ± 18 ml O2/min, P < 0.05, control vs. AOC, respectively) during exercise in COPD, whereas no effect was observed in healthy subjects. In addition, the AOC afforded a small, but significant, improvement in arterial O2 saturation only in patients with COPD. Thus, these data demonstrate a novel beneficial role of AOC administration on exercising LBF, O2 consumption, and arterial O2 saturation in patients with COPD, implicating oxidative stress as a potential therapeutic target for impaired exercise capacity in this population. PMID:26188020

  13. Fingolimod (FTY-720) is Capable of Reversing Tumor Necrosis Factor Induced Decreases in Cochlear Blood Flow.

    PubMed

    Bertlich, Mattis; Ihler, Friedrich; Weiss, Bernhard G; Freytag, Saskia; Jakob, Mark; Strupp, Michael; Pellkofer, Hannah; Canis, Martin

    2017-09-01

    The potential of Fingolimod (FTY-720), a sphingosine-1-phosphate analogue, to revoke the changes in cochlear blood flow induced by tumor necrosis factor (TNF) was investigated. Impairment of cochlear blood flow has often been considered as the common final pathway of various inner ear pathologies. TNF, an ubiquitous cytokine, plays a major role in these pathologies, reducing cochlear blood flow via sphingosine-1-phosphate-signaling. Fifteen Dunkin-Hartley guinea pigs were randomly assigned to one of three groups (placebo/placebo, TNF/placebo, TNF/FTY-720). Cochlear microcirculation was quantified over 60 minutes by in vivo fluorescence microscopy before and after topical application of placebo or TNF (5 ng/ml) and after subsequent application of placebo or FTY-720 (200 μg/ml). Treatment with TNF led to a significant decrease of cochlear blood flow.Following this, application of placebo caused no significant changes while application of FTY-720 caused a significant rise in cochlear blood flow. FTY-720 is capable of reversing changes in cochlear blood flow induced by application of TNF. This makes FTY-720 a valid candidate for potential treatment of numerous inner ear pathologies.

  14. Cardiopulmonary capacities of Malaysian females.

    PubMed

    Singh, R; Singh, H J; Sirisinghe, R G

    1995-04-01

    Aerobic capacity (VO2max) and lung capacities were measured in 66 healthy females ranging in age from 13 to 49 years. Forced vital capacity (FVC) and peak expiratory flow rate (PEFR) were measured using a dry spirometer and Wrights peak flow meter respectively. Cardiopulmonary parameters were obtained from a progressive ergocycle test to exhaustion. Mean FVC and PEFR obtained were 2.73 +/- 0.07 L and 412 +/- 8.5 L/min respectively. FVC correlated negatively with age in subjects from the 3rd to 5th decade of age (r = 0.38, p < 0.05). Mean VO2max was 43.2 +/- 0.9 ml/kg/min in the 2nd decade compared to 30.3 +/- 0.7 ml/kg/min in the fifth decade. Regression analysis revealed an age related decline in VO2max of 0.45 +/- 0.8 ml/kg/min/year, which was found to be somewhat higher compared to other studies.

  15. Dynamic viscoelasticity measurement under alternative torque using electromagnetically spinning method with quadruple electromagnets.

    PubMed

    Matsuura, Yusuke; Hirano, Taichi; Sakai, Keiji

    2017-07-01

    In this study, we developed a novel type of rheological measurement system. Here, a spherical probe is driven to rotate periodically by applying torques using quadruple electromagnets in a noncontact manner. Moreover, this system is an enhancement of our electromagnetically spinning (EMS) viscometer, which is widely used for measuring rheological flow curves in various industrial fields. The quadruple EMS method provides the frequency spectrum of viscoelasticity, in addition to shear viscosity, in a steady flow by switching the operation modes of the driving torque. We show the results obtained for Newtonian fluids and viscoelastic materials and demonstrate the validity of the system.

  16. Two-column sequential injection chromatography--new approach for fast and effective analysis and its comparison with gradient elution chromatography.

    PubMed

    Chocholous, Petr; Satínský, Dalibor; Sklenárová, Hana; Solich, Petr

    2010-05-23

    This work presents novel approach in low-pressure chromatography flow systems--two-column Sequential Injection Chromatography (2-C SIC) and its comparison with gradient elution chromatography on the same instrument. The system was equipped with two different chromatographic columns (connected to selection valve in parallel design) for isocratic separation and determination of all components in composed anti-inflammatory pharmaceutical preparation (tablets). The sample was first injected on the first column of length 30 mm where less retained analytes were separated and then the sample was injected on the second column of length 10 mm where more retained analytes were separated. The SIC system was based on a commercial SIChrom manifold (8-port high-pressure selection valve and medium-pressure syringe pump with 4 mL reservoir) (FIAlab, USA) with two commercially available monolithic columns the "first column" Chromolith Flash RP-18e (25 mm x 4.6 mm i.d. with guard column 5 mm x 4.6 mm i.d.) and the "second column" Chromolith RP-18e (10 mm x 4.6 mm i.d.) and CCD UV-vis detector USB 4000 with micro-volume 1.0 cm Z flow cell. Two mobile phases were used for analysis (one for each column). The mobile phase 1 used for elution of paracetamol, caffeine and salicylic acid (internal standard) was acetonitrile/water (10:90, v/v, the water part of pH 3.5 adjusted with acetic acid), flow rate was 0.9 mL min(-1) (volume 3.0 mL of mobile phase per analysis). The mobile phase 2 used for elution of propyphenazone was acetonitrile/water (30:70, v/v); flow rate was 1.2 mL min(-1) (volume 1.5 mL of mobile phase per analysis). Absorbance was monitored at 210 nm. Samples were prepared by dissolving of one tablet in 30% acetonitrile and 10 microL of filtered supernatant was injected on each column (2 x 10 microL). The chromatographic resolution between all compounds was >1.45 and analysis time was 5.5 min under the optimal conditions. Limits of detection were determined at 0.4 microg mL(-1) for paracetamol, at 0.5 microg mL(-1) for caffeine and at 0.7 microg mL(-1) for propyphenazone. The new two-column chromatographic set-up developed as an alternative approach to gradient elution chromatography shows evident advantages (time and solvent reduction more than one-third) as compared with single-column gradient SIC method with Chromolith Flash RP-18 (25 mm x 4.6 mm i.d. with guard column 5 mm x 4.6 mm i.d.). Copyright 2010 Elsevier B.V. All rights reserved.

  17. Puffing Topography and Nicotine Intake of Electronic Cigarette Users

    PubMed Central

    Behar, Rachel Z.; Hua, My; Talbot, Prue

    2015-01-01

    Background Prior electronic cigarette (EC) topography data are based on two video analyses with limited parameters. Alternate methods for measuring topography are needed to understand EC use and nicotine intake. Objectives This study evaluated EC topography with a CReSS Pocket device and quantified nicotine intake. Methods Validation tests on pressure drop, flow rate, and volume confirmed reliable performance of the CReSS Pocket device. Twenty participants used Blu Cigs and V2 Cigs for 10 minute intervals with a 10–15 minute break between brands. Brand order was reversed and repeated within 7 days Data were analyzed to determine puff duration, puff count, volume, flow rate, peak flow, and inter-puff interval. Nicotine intake was estimated from cartomizer fluid consumption and topography data. Results Nine patterns of EC use were identified. The average puff count and inter-puff interval were 32 puffs and 17.9 seconds. All participants, except one, took more than 20 puffs/10 minutes. The averages for puff duration (2.65 seconds/puff), volume/puff (51ml/puff), total puff volume (1,579 ml), EC fluid consumption (79.6 mg), flow rate (20 ml/s), and peak flow rate (27 ml/s) were determined for 10-minute sessions. All parameters except total puff count were significantly different for Blu versus V2 EC. Total volume for Blu versus V2 was four-times higher than for conventional cigarettes. Average nicotine intake for Blu and V2 across both sessions was 1.2 ± 0.5 mg and 1.4 ± 0.7 mg, respectively, which is similar to conventional smokers. Conclusions EC puffing topography was variable among participants in the study, but often similar within an individual between brands or days. Puff duration, inter-puff interval, and puff volume varied from conventional cigarette standards. Data on total puff volume and nicotine intake are consistent with compensatory usage of EC. These data can contribute to the development of a standard protocol for laboratory testing of EC products. PMID:25664463

  18. Assessment of volume and leak measurements during CPAP using a neonatal lung model.

    PubMed

    Fischer, H S; Roehr, C C; Proquitté, H; Wauer, R R; Schmalisch, G

    2008-01-01

    Although several commercial devices are available which allow tidal volume and air leak monitoring during continuous positive airway pressure (CPAP) in neonates, little is known about their measurement accuracy and about the influence of air leaks on volume measurement. The aim of this in vitro study was the validation of volume and leak measurement under CPAP using a commercial ventilatory device, taking into consideration the clinical conditions in neonatology. The measurement accuracy of the Leoni ventilator (Heinen & Löwenstein, Germany) was investigated both in a leak-free system and with leaks simulated using calibration syringes (2-10 ml, 20-100 ml) and a mechanical lung model. Open tubes of variable lengths were connected for leak simulation. Leak flow was measured with the flow-through technique. In a leak-free system the mean relative volume error +/-SD was 3.5 +/- 2.6% (2-10 ml) and 5.9 +/- 0.7% (20-60 ml), respectively. The influence of CPAP level, driving flow, respiratory rate and humidification of the breathing gas on the volume error was negligible. However, an increasing F(i)O(2) caused the measured tidal volume to increase by up to 25% (F(i)O(2) = 1.0). The relative error +/- SD of the leak measurements was -0.2 +/- 11.9%. For leaks > 19%, measured tidal volume was underestimated by more than 10%. In conclusion, the present in vitro study showed that the Leoni allowed accurate volume monitoring under CPAP conditions similar to neonates. Air leaks of up to 90% of patient flow were reliably detected. For an F(i)O(2) > 0.4 and for leaks > 19%, a numerical correction of the displayed volume should be performed.

  19. CytometryML, an XML format based on DICOM and FCS for analytical cytology data.

    PubMed

    Leif, Robert C; Leif, Suzanne B; Leif, Stephanie H

    2003-07-01

    Flow Cytometry Standard (FCS) was initially created to standardize the software researchers use to analyze, transmit, and store data produced by flow cytometers and sorters. Because of the clinical utility of flow cytometry, it is necessary to have a standard consistent with the requirements of medical regulatory agencies. We extended the existing mapping of FCS to the Digital Imaging and Communications in Medicine (DICOM) standard to include list-mode data produced by flow cytometry, laser scanning cytometry, and microscopic image cytometry. FCS list-mode was mapped to the DICOM Waveform Information Object. We created a collection of Extensible Markup Language (XML) schemas to express the DICOM analytical cytologic text-based data types except for large binary objects. We also developed a cytometry markup language, CytometryML, in an open environment subject to continuous peer review. The feasibility of expressing the data contained in FCS, including list-mode in DICOM, was demonstrated; and a preliminary mapping for list-mode data in the form of XML schemas and documents was completed. DICOM permitted the creation of indices that can be used to rapidly locate in a list-mode file the cells that are members of a subset. DICOM and its coding schemes for other medical standards can be represented by XML schemas, which can be combined with other relevant XML applications, such as Mathematical Markup Language (MathML). The use of XML format based on DICOM for analytical cytology met most of the previously specified requirements and appears capable of meeting the others; therefore, the present FCS should be retired and replaced by an open, XML-based, standard CytometryML. Copyright 2003 Wiley-Liss, Inc.

  20. Altered coronary endothelial function in young smokers detected by magnetic resonance assessment of myocardial blood flow during the cold pressor test.

    PubMed

    Ichikawa, Yasutaka; Kitagawa, Kakuya; Kato, Shingo; Dohi, Kaoru; Hirano, Tadanori; Ito, Masaaki; Sakuma, Hajime

    2014-06-01

    Endothelial dysfunction is a key element in early atherogenesis. The purposes of this study were to evaluate the feasibility of magnetic resonance (MR) assessment of altered myocardial blood flow (MBF) in response to the cold pressor test (CPT) and to determine if coronary endothelial dysfunction in young smokers can be detected with this noninvasive approach. Fourteen healthy non-smokers (31 ± 6 years) and 12 smokers (34 ± 8 years) were studied. Breath-hold phase-contrast cine MR imaging (PC-MRI) of the coronary sinus (CS) were obtained at rest and during the CPT. MBF was measured as CS flow divided by left ventricle mass and the rate pressure product. In non-smokers, MBF was 0.88 ± 0.19 ml/min/g at rest and significantly increased to 1.13 ± 0.26 ml/min/g during the CPT (P = 0.0001). In smokers, MBF was 0.94 ± 0.26 ml/min/g at rest and 0.96 ± 0.30 ml/min/g during the CPT (P = 0.73). ΔMBF (MBF during the CPT-MBF at rest) was significantly reduced in smokers compared with non-smokers (0.02 ± 0.20 vs. 0.26 ± 0.18 ml/min/g, P = 0.005). The intra-class correlation coefficient between measurements by two observers was 0.90 for ΔMBF. A significant reduction in MBF response to CPT was demonstrated in young smokers with PC-MRI at 1.5 T. This noninvasive method has great potential for assessment of coronary endothelial function.

  1. An open-loop controlled active lung simulator for preterm infants.

    PubMed

    Cecchini, Stefano; Schena, Emiliano; Silvestri, Sergio

    2011-01-01

    We describe the underlying theory, design and experimental evaluation of an electromechanical analogue infant lung to simulate spontaneous breathing patterns of preterm infants. The aim of this work is to test the possibility to obtain breathing patterns of preterm infants by taking into consideration the air compressibility. Respiratory volume function represents the actuation pattern, and pulmonary pressure and flow-rate waveforms are mathematically obtained through the application of the perfect gas and adiabatic laws. The mathematical model reduces the simulation interval into a step shorter than 1 ms, allowing to consider an entire respiratory act as composed of a large number of almost instantaneous adiabatic transformations. The device consists of a spherical chamber where the air is compressed by four cylinder-pistons, moved by stepper motors, and flows through a fluid-dynamic resistance, which also works as flow-rate sensor. Specifically designed software generates the actuators motion, based on the desired ventilation parameters, without controlling the gas pneumatic parameters with a closed-loop. The system is able to simulate tidal volumes from 3 to 8 ml, breathing frequencies from 60 to 120 bpm and functional residual capacities from 25 to 80 ml. The simulated waveforms appear very close to the measured ones. Percentage differences on the tidal volume waveform vary from 7% for the tidal volume of 3 ml, down to 2.2-3.5% for tidal volumes in the range of 4-7 ml, and 1.3% for the tidal volume equal to 8 ml in the whole breathing frequency and functional residual capacity ranges. The open-loop electromechanical simulator shows that gas compressibility can be theoretically assessed in the typical pneumatic variable range of preterm infant respiratory mechanics. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  2. Time-of-flight PET image reconstruction using origin ensembles.

    PubMed

    Wülker, Christian; Sitek, Arkadiusz; Prevrhal, Sven

    2015-03-07

    The origin ensemble (OE) algorithm is a novel statistical method for minimum-mean-square-error (MMSE) reconstruction of emission tomography data. This method allows one to perform reconstruction entirely in the image domain, i.e. without the use of forward and backprojection operations. We have investigated the OE algorithm in the context of list-mode (LM) time-of-flight (TOF) PET reconstruction. In this paper, we provide a general introduction to MMSE reconstruction, and a statistically rigorous derivation of the OE algorithm. We show how to efficiently incorporate TOF information into the reconstruction process, and how to correct for random coincidences and scattered events. To examine the feasibility of LM-TOF MMSE reconstruction with the OE algorithm, we applied MMSE-OE and standard maximum-likelihood expectation-maximization (ML-EM) reconstruction to LM-TOF phantom data with a count number typically registered in clinical PET examinations. We analyzed the convergence behavior of the OE algorithm, and compared reconstruction time and image quality to that of the EM algorithm. In summary, during the reconstruction process, MMSE-OE contrast recovery (CRV) remained approximately the same, while background variability (BV) gradually decreased with an increasing number of OE iterations. The final MMSE-OE images exhibited lower BV and a slightly lower CRV than the corresponding ML-EM images. The reconstruction time of the OE algorithm was approximately 1.3 times longer. At the same time, the OE algorithm can inherently provide a comprehensive statistical characterization of the acquired data. This characterization can be utilized for further data processing, e.g. in kinetic analysis and image registration, making the OE algorithm a promising approach in a variety of applications.

  3. Time-of-flight PET image reconstruction using origin ensembles

    NASA Astrophysics Data System (ADS)

    Wülker, Christian; Sitek, Arkadiusz; Prevrhal, Sven

    2015-03-01

    The origin ensemble (OE) algorithm is a novel statistical method for minimum-mean-square-error (MMSE) reconstruction of emission tomography data. This method allows one to perform reconstruction entirely in the image domain, i.e. without the use of forward and backprojection operations. We have investigated the OE algorithm in the context of list-mode (LM) time-of-flight (TOF) PET reconstruction. In this paper, we provide a general introduction to MMSE reconstruction, and a statistically rigorous derivation of the OE algorithm. We show how to efficiently incorporate TOF information into the reconstruction process, and how to correct for random coincidences and scattered events. To examine the feasibility of LM-TOF MMSE reconstruction with the OE algorithm, we applied MMSE-OE and standard maximum-likelihood expectation-maximization (ML-EM) reconstruction to LM-TOF phantom data with a count number typically registered in clinical PET examinations. We analyzed the convergence behavior of the OE algorithm, and compared reconstruction time and image quality to that of the EM algorithm. In summary, during the reconstruction process, MMSE-OE contrast recovery (CRV) remained approximately the same, while background variability (BV) gradually decreased with an increasing number of OE iterations. The final MMSE-OE images exhibited lower BV and a slightly lower CRV than the corresponding ML-EM images. The reconstruction time of the OE algorithm was approximately 1.3 times longer. At the same time, the OE algorithm can inherently provide a comprehensive statistical characterization of the acquired data. This characterization can be utilized for further data processing, e.g. in kinetic analysis and image registration, making the OE algorithm a promising approach in a variety of applications.

  4. Validation of an HPLC method for the determination of urinary and plasma levels of N1-methylnicotinamide, an endogenous marker of renal cationic transport and plasma flow.

    PubMed

    Musfeld, C; Biollaz, J; Bélaz, N; Kesselring, U W; Decosterd, L A

    2001-01-01

    N1-Methylnicotinamide (NMN) is an endogenous cationic metabolite of nicotinamide (niacine, vitamine PP) whose renal clearance reflects both the capacity of the renal tubular transport system to secrete organic cations and renal plasma flow. NMN is present in human plasma and urine at the 1-117-ng ml(-1) and 0.5-25-microg ml(-1) concentration range, respectively, and its level depends notably on pathophysiological (age, renal or hepatic diseases) conditions. We report the optimization and validation of an HPLC method for the measurement of endogenous NMN in biological fluids after derivatization into a fluorescent compound. Plasma is first deproteinized with TCA 20% and the urine diluted 1:10 with HCI 10(-4) M prior to the derivatization procedure, which includes a condensation reaction of NMN with acetophenone in NaOH at 0 degrees C, followed by dehydration in formic acid and subsequent formation of the fluorescent 1,6-naphthyridine derivatives after heating samples in a boiling water bath. The synthetic homologous derivative N1-ethylnicotinamide (NEN) reacts similarly and is added as internal standard into the biological fluid. The reaction mixture is subjected to reverse phase high performance liquid chromatography on a Nucleosil 100-C18 column using a mobile phase (acetonitrile 22%, triethylamine 0.5%, 0.01 M sodium heptanesulfonate adjusted to pH 3.2), delivered isocratically at a flow rate of 1 ml min(-1), NMN and NEN are detected at 7.8 and 10 min by spectrofluorimetry with excitation and emission wavelengths set at 366 and 418 nm, respectively. The addition-calibration method is used with plasma and urine pools. Calibration curves (using the internal standard method) are linear (r2 > 0.997) at concentrations up to 109 ng ml(-1) and 15.7 microg ml(-1) in plasma and urine, respectively. Both intra- and inter-assay precision of plasma control samples at 10, 50 and 90 ng ml(-1) were lower than 3.3% and concentrations not deviating more than 2.7% from their nominal values. In urine intra- and inter-assay CVs of control samples at 1, 5 and 9 microg ml(-1) are lower than 8.3%, with concentrations not deviating more than -9.0 to +11.8% from their nominal values. This analytical method has therefore the required sensitivity and selectivity to measure NMN in plasma and urine, enabling the non-invasive determination of the tubular secretory capacity of the kidney and the renal plasma flow.

  5. THE EFFECT OF RATE OF GLAND FUNCTION ON PAROTID FLUID URIC ACID LEVELS.

    DTIC Science & Technology

    Paired parotid fluid samples were collected without exogenous stimulation and at 5 different gustation-induced rates of flow. Enzymatic uric acid...diminished as flow rate increased. It is suggested that parotid fluid samples for uric acid analysis should be collected at flow rates of 0.7 ml./min. or more. (Author)

  6. A microvolume molecularly imprinted polymer modified fiber-optic evanescent wave sensor for bisphenol A determination.

    PubMed

    Xiong, Yan; Ye, Zhongbin; Xu, Jing; Liu, Yucheng; Zhang, Hanyin

    2014-04-01

    A fiber-optic evanescent wave sensor for bisphenol A (BPA) determination based on a molecularly imprinted polymer (MIP)-modified fiber column was developed. MIP film immobilized with BPA was synthesized on the fiber column, and the sensor was then constructed by inserting the optical fiber prepared into a transparent capillary. A microchannel (about 2.0 μL) formed between the fiber and the capillary acted as a flow cell. BPA can be selectively adsorbed online by the MIP film and excited to produce fluorescence by the evanescent wave produced on the fiber core surface. The conditions for BPA enrichment, elution, and fluorescence detection are discussed in detail. The analytical measurements were made at 276 nm/306 nm (λ(ex)/λ(em)), and linearity of 3 × 10(-9)-5 × 10(-6) g mL(-1) BPA, a limit of detection of 1.7 × 10(-9) g mL(-1) BPA (3σ), and a relative standard deviation of 2.4% (n = 5) were obtained. The sensor selectivity and MIP binding measurement were also evaluated. The results indicated that the selectivity and sensitivity of the proposed fiber-optic sensor could be greatly improved by using MIP as a recognition and enrichment element. Further, by modification of the sensing and detection elements on the optical fiber, the proposed sensor showed the advantages of easy fabrication and low cost. The novel sensor configuration provided a platform for monitoring other species by simply changing the light source and sensing elements. The sensor presented has been successfully applied to determine BPA released from plastic products treated at different temperatures.

  7. Early pleural fluid dynamics following video-assisted thoracoscopic lobectomy has limited clinical value

    PubMed Central

    Holbek, Bo Laksáfoss; Petersen, René Horsleben; Kehlet, Henrik

    2017-01-01

    The objective of this study was to evaluate the potential of predicting the pleural fluid output in patients after video-assisted thoracoscopic lobectomy of the lung. Detailed measurements of continuous fluid output were obtained prospectively using an electronic thoracic drainage device (Thopaz+™, Medela AG, Switzerland). Patients were divided into high (≥500 mL) and low (<500 mL) 24-hour fluid output, and detailed flow curves were plotted graphically to identify arithmetic patterns predicting fluid output in the early (≤24 hours) and later (24–48 hours) post-operative phase. Furthermore, multiple logistic regression analysis was used to predict high 24-hour fluid output using baseline data. Data were obtained from 50 patients, where 52% had a fluid output of <500 mL/24 hours. From visual assessment of flow curves, patients were grouped according to fluid output 6 hours postoperatively. An output ≥200 mL/6 hours was predictive of ‘high 24-hour fluid output’ (P<0.0001). However, 33% of patients with <200 mL/6 hours ended with a ‘high 24-hour fluid output’. Baseline data showed no predictive value of fluid production, and 24-hour fluid output had no predictive value of fluid output between 24 and 48 hours. Assessment of initial fluid production may predict high 24-hour fluid output (≥500 mL) but seems to lack clinical value in drain removal criteria. PMID:28840021

  8. Extracorporeal Carbon Dioxide Removal Enhanced by Lactic Acid Infusion in Spontaneously Breathing Conscious Sheep.

    PubMed

    Scaravilli, Vittorio; Kreyer, Stefan; Belenkiy, Slava; Linden, Katharina; Zanella, Alberto; Li, Yansong; Dubick, Michael A; Cancio, Leopoldo C; Pesenti, Antonio; Batchinsky, Andriy I

    2016-03-01

    The authors studied the effects on membrane lung carbon dioxide extraction (VCO2ML), spontaneous ventilation, and energy expenditure (EE) of an innovative extracorporeal carbon dioxide removal (ECCO2R) technique enhanced by acidification (acid load carbon dioxide removal [ALCO2R]) via lactic acid. Six spontaneously breathing healthy ewes were connected to an extracorporeal circuit with blood flow 250 ml/min and gas flow 10 l/min. Sheep underwent two randomly ordered experimental sequences, each consisting of two 12-h alternating phases of ALCO2R and ECCO2R. During ALCO2R, lactic acid (1.5 mEq/min) was infused before the membrane lung. Caloric intake was not controlled, and animals were freely fed. VCO2ML, natural lung carbon dioxide extraction, total carbon dioxide production, and minute ventilation were recorded. Oxygen consumption and EE were calculated. ALCO2R enhanced VCO2ML by 48% relative to ECCO2R (55.3 ± 3.1 vs. 37.2 ± 3.2 ml/min; P less than 0.001). During ALCO2R, minute ventilation and natural lung carbon dioxide extraction were not affected (7.88 ± 2.00 vs. 7.51 ± 1.89 l/min, P = 0.146; 167.9 ± 41.6 vs. 159.6 ± 51.8 ml/min, P = 0.063), whereas total carbon dioxide production, oxygen consumption, and EE rose by 12% each (223.53 ± 42.68 vs. 196.64 ± 50.92 ml/min, 215.3 ± 96.9 vs. 189.1 ± 89.0 ml/min, 67.5 ± 24.0 vs. 60.3 ± 20.1 kcal/h; P less than 0.001). ALCO2R was effective in enhancing VCO2ML. However, lactic acid caused a rise in EE that made ALCO2R no different from standard ECCO2R with respect to ventilation. The authors suggest coupling lactic acid-enhanced ALCO2R with active measures to control metabolism.

  9. Portal hemodynamic responses after oral intake of glucose in patients with cirrhosis.

    PubMed

    Tsunoda, T; Ohnishi, K; Tanaka, H

    1988-04-01

    Changes of portal, superior mesenteric, and splenic venous flows, and portohepatic gradient (portal vein pressure minus free hepatic vein pressure) after a meal were studied in patients with cirrhosis using the duplex ultrasonic Doppler flowmeter, and portal and hepatic vein catheterizations after ingestion of 227 ml of 33% glucose solution (300 kcal). As a control, changes of portal venous flow and portohepatic gradient after drinking 227 ml of water, were studied. Portal and superior mesenteric venous flows increased significantly at 30 min after glucose intake, and they returned gradually to the basal values, whereas no significant postprandial change occurred in splenic venous flow. The sum of superior mesenteric and splenic venous flows was greater than the estimated portal venous flow before glucose intake, and the difference widened during post-prandial mesenteric hyperemia, indicating an increase of blood flow into the portal-systemic shunts. After glucose intake, portohepatic gradient elevated immediately, in parallel with an increase of portal venous flow, and these changes persisted for the 30 min studied; however, no significant change occurred in these parameters after drinking water. 1) In patients with cirrhosis, hyperemia occurs in the intestine but not in the spleen after glucose intake, and 2) postprandial mesenteric hyperemia causes an increase of portal venous inflow, portal-systemic collateral flow, portal venous flow, and an elevation of portohepatic gradient.

  10. Progressive impairment of regional myocardial perfusion after initial restoration of postischemic blood flow.

    PubMed

    Ambrosio, G; Weisman, H F; Mannisi, J A; Becker, L C

    1989-12-01

    The "no-reflow" phenomenon, the occurrence of areas with very low flow in hearts reperfused after ischemia, is thought to be largely established at the time of reperfusion as a result of microvascular damage induced by ischemia. In the present study we sought to determine whether additional impairment of tissue perfusion might also occur during the course of reperfusion. Open-chest dogs were subjected to 90 minutes of left circumflex coronary artery occlusion and reperfused for 2 minutes (n = 7) or 3.5 hours (n = 8). Myocardial perfusion was visualized in left ventricular slices following in vivo injection of the fluorescent dye thioflavin-S just before killing. The area of impaired perfusion (absent thioflavin) averaged 9.5 +/- 3.0% of the risk region in dogs reperfused for 2 minutes, whereas it was nearly three times as large in dogs reperfused for 3.5 hours (25.9 +/- 8.2% of the risk region, p less than 0.05). Serial measurements of flow by microspheres during reperfusion demonstrated zones within the postischemic myocardium that were hyperemic 2 minutes after reperfusion, with adequate flow still present at 30 minutes, but with a subsequent marked fall in perfusion. After 3.5 hours these areas showed negligible flow (0.13 +/- 0.3 ml/min/g) and no thioflavin uptake. Tissue samples showing postischemic impairment in perfusion has received virtually no collateral flow during ischemia (less than 0.01 ml/min/g), whereas collateral flow was significantly higher in adjacent thioflavin-positive zones (0.04 +/- 0.01 ml/min/g in endocardial samples and 0.07 +/- 0.02 ml/min/g in samples from the midmyocardium, p less than 0.001 vs. thioflavin-negative areas). Areas that showed late impairment of flow invariably demonstrated contraction band necrosis, which contrasted with the pattern of coagulation necrosis observed in areas of "true" (i.e., immediate) no-reflow. Intracapillary erythrocyte stasis and marked intravascular neutrophil accumulation (to levels greater than 20-fold that found after 2 minutes reperfusion) were typically observed in areas of delayed impairment to flow. Obstruction to flow at the capillary level was confirmed in additional dogs in which the heart was injected postmortem with silicone rubber to delineate the microvascular filling pattern. Areas of absent capillary filling were much more extensive after 3.5 hours than after 2 minutes reperfusion. Thus, this study shows that the occurrence of areas of markedly impaired perfusion in postischemic myocardium is related only in part to an inability to reperfuse certain areas on reflow. A more important factor is represented by a delayed, progressive fall in flow to areas that initially received adequate reperfusion.(ABSTRACT TRUNCATED AT 400 WORDS)

  11. Effects of equine metabolic syndrome on inflammatory responses of horses to intravenous lipopolysaccharide infusion.

    PubMed

    Tadros, Elizabeth M; Frank, Nicholas; Donnell, Robert L

    2013-07-01

    To test the hypothesis that inflammatory responses to endotoxemia differ between healthy horses and horses with equine metabolic syndrome (EMS). Animals-6 healthy horses and 6 horses with EMS. Each horse randomly received an IV infusion of lipopolysaccharide (20 ng/kg [in 60 mL of sterile saline {0.9% NaCl} solution]) or saline solution, followed by the other treatment after a 7-day washout period. Baseline data were obtained 30 minutes before each infusion. After infusion, a physical examination was performed hourly for 9 hours and at 15 and 21 hours; a whole blood sample was collected at 30, 60, 90, 120, 180, and 240 minutes for assessment of inflammatory cytokine gene expression. Liver biopsy was performed between 240 and 360 minutes after infusion. Results-Following lipopolysaccharide infusion in healthy horses and horses with EMS, mean rectal temperature, heart rate, and respiratory rate increased, compared with baseline findings, as did whole blood gene expression of interleukin (IL)-1β, IL-6, IL-8, IL-10, and tumor necrosis factor-α. The magnitude of blood cytokine responses did not differ between groups, but increased expression of IL-6, IL-8, IL-10, and tumor necrosis factor-α persisted for longer periods in EMS-affected horses. Lipopolysaccharide infusion increased liver tissue gene expressions of IL-6 in healthy horses and IL-8 in both healthy and EMS-affected horses, but these gene expressions did not differ between groups. Results supported the hypothesis that EMS affects horses' inflammatory responses to endotoxin by prolonging cytokine expression in circulating leukocytes. These findings are relevant to the association between obesity and laminitis in horses with EMS.

  12. Infrared Imaging of Nitric Oxide-Mediated Blood Flow in Human Sickle Cell Disease

    PubMed Central

    Gorbach, Alexander M.; Ackerman, Hans C.; Liu, Wei-Min; Meyer, Joseph M.; Littel, Patricia L.; Seamon, Catherine; Footman, Eleni; Chi, Amy; Zorca, Suzana; Krajewski, Megan L.; Cuttica, Michael J.; Machado, Roberto F.; Cannon, Richard O.; Kato, Gregory J.

    2012-01-01

    Vascular dysfunction is an important pathophysiologic manifestation of sickle cell disease (SCD), a condition that increases risk of pulmonary hypertension and stroke. We hypothesized that infrared (IR) imaging would detect changes in cutaneous blood flow reflective of vascular function. We performed IR imaging and conventional strain gauge plethysmography in twenty-five adults with SCD at baseline and during intra-arterial infusions of an endothelium-dependent vasodilator acetylcholine (ACh), an endothelium-independent vasodilator sodium nitroprusside (SNP), and a NOS inhibitor L-NMMA. Skin temperature measured by IR imaging increased in a dose-dependent manner to graded infusions of ACh (+1.1° C, p < 0.0001) and SNP (+0.9° C, p < 0.0001), and correlated with dose-dependent increases in forearm blood flow (ACh: +19.9 mL/min/100mL, p < 0.0001; rs = 0.57, p = 0.003; SNP: +8.6 mL/min/100mL, p < 0.0001; r = 0.70, p = 0.0002). Although IR measurement of skin temperature accurately reflected agonist-induced increases in blood flow, it was less sensitive to decreases in blood flow caused by NOS inhibition. Baseline forearm skin temperature measured by IR imaging correlated significantly with baseline forearm blood flow (31.8±0.2° C, 6.0±0.4 mL/min/100mL; r = 0.58, p = 0.003), and appeared to represent a novel biomarker of vascular function. It predicted a blunted blood flow response to SNP (r = −0.61, p = 0.002), and was independently associated with a marker of pulmonary artery pressure, as well as hemoglobin level, diastolic blood pressure, homocysteine, and cholesterol (R2 = 0.84, p < 0.0001 for the model). IR imaging of agonist-stimulated cutaneous blood flow represents a less cumbersome alternative to plethysmography methodology. Measurement of baseline skin temperature by IR imaging may be a useful new marker of vascular risk in adults with SCD. PMID:22784510

  13. A Study Demonstrating the Quantitative Relationship Between Internal Thoracic Artery Length and Free Flow.

    PubMed

    Gode, Safa; Sen, Onur; Kadirogulları, Ersin; Reyhancan, Adem; Kyaruzi, Mugisha; Satılmısoglu, Muhammet Hulusi; Erkanlı, Korhan

    2017-08-09

    The left internal thoracic artery (LITA) is the most commonly used arterial bypass conduit in coronary artery bypass graft (CABG) patients and inadequate LITA flow can result in an increase in morbidity and mortality. In this study, we evaluated the effect of excision of the distal spasmodic segment of the LITA on the free flow in CABG patients. This study consisted of 47 patients who underwent elective CABG performed with or without other cardiac surgery, between July 2015 and December 2015. Excised LITA length was shorter than 15mm in group 1, between 15mm and 30mm in group 2 and longer than 30mm in group 3. Left ITA free flow was measured for 60seconds into a container before and after the distal LITA excision. The inter-measurement differences were calculated for the three groups. Thereafter, the comparison was performed in terms of free flow difference amongst the three groups. The mean difference of LITA free flow was 27.6±22.7ml/minute in group 1, 35.4±26.7ml/minute in group 2, and 52.6±26.1ml/minute in group 3. There were significant differences in terms of free flow difference between the groups (p=0.008). Also, differences were statistically significant in group 1 versus group 3 (p=0.003) and group 2 versus group 3 (p=0.038) in the intergroup comparisons. The distal part of the LITA has more spasmodic potential than other segments. This spasm may result in low flow of LITA grafts. Therefore, an as long as possible excision of the distal LITA segment may be required to avoid the spasmodic effect. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  14. A high selective cataluminescence sensor for the determination of tetrahydrofuran vapor

    NASA Astrophysics Data System (ADS)

    Cao, Xiaoan; Dai, Huimei; Chen, Suilin; Zeng, Jiayi; Zhang, Keke; Sun, Yan

    2013-02-01

    A novel tetrahydrofuran (THF) vapor sensor was designed based on the cataluminescence (CTL) of THF on nanosized γ-Al2O3/MgO (mol ratio = 1.5:1). SEM and XRD were applied for its characterization. We found that the CTL was strongly produced when THF vapor flowed through a nanosized Al-Mg mixed-metal oxide surface, while the CTL was weakly generated when THF vapor flowed through a single nanosized γ-Al2O3 or MgO surface. Quantitative analysis was performed at an optimal temperature of 279 °C, a wavelength of 460 nm and a flow rate of 360 mL min-1. The linear range of the CTL intensity versus concentrations of THF vapor was 1.0-3000 mL m-3 with a detection limit of 0.67 mL m-3. No (or only very low) interference was observed by formaldehyde, methanol, ethanol, benzene, toluene, ethyl acetate, ammonia, cyclohexane, chloroform, glycol armour ether, glycol ether, isopropyl ether and n-butyl ether or acetic acid. Since the response of the sensor was rapid and the system was easy to handle, we believe that the sensor has great potential for real-world use.

  15. Fountain Flow cytometry, a new technique for the rapid detection and enumeration of microorganisms in aqueous samples.

    PubMed

    Johnson, Paul E; Deromedi, Anthony J; Lebaron, Philippe; Catala, Philippe; Cash, Jennifer

    2006-12-01

    Pathogenic microorganisms are known to cause widespread waterborne disease worldwide. There is an urgent need to develop a technique for the real-time detection of pathogens in environmental samples at low concentrations, <10 microorganisms/ml, in large sample volumes, > or =100 ml. A novel method, Fountain Flowtrade mark cytometry, for the rapid and sensitive detection of individual microorganisms in aqueous samples is presented. Each sample is first incubated with a fluorescent label and then passed as a stream in front of a laser, which excites the label. The fluorescence is detected with a CCD imager as the sample flows toward the imager along its optical axis. The feasibility of Fountain Flow cytometry (FFC) is demonstrated by the detection of Escherichia coli labeled with ChemChrome CV6 and SYBR Gold in buffer and natural river water. Detections of labeled E. coli were made in aqueous suspensions with an efficiency of 96% +/- 14% down to a concentration approximately 200 bacteria/ml. The feasibility of FFC is demonstrated by the detection of E. coli in buffer and natural river water. FFC should apply to the detection of a wide range of pathogenic microorganisms including amoebae.

  16. Carbon monoxide and methane adsorption of crude oil refinery using activated carbon from palm shells as biosorbent

    NASA Astrophysics Data System (ADS)

    Yuliusman; Afdhol, M. K.; Sanal, Alristo

    2018-03-01

    Carbon monoxide and methane gas are widely present in oil refineries. Off-potential gas is used as raw material for the petrochemical industry. In order for this off-gas to be utilized, carbon monoxide and methane must be removed from off-gas. This study aims to adsorb carbon monoxide and methane using activated carbon of palm shells and commercial activated carbon simultaneously. This research was conducted in 2 stages: 1) Preparation and characterization of activated carbon, 2) Carbon monoxide and methane adsorption test. The activation experiments using carbon dioxide at a flow rate of 150 ml/min yielded a surface area of 978.29 m2/g, Nitrogen at flow rate 150 ml/min yielded surface area 1241.48 m2/g, and carbon dioxide and nitrogen at a flow rate 200 ml/min yielded a surface area 300.37 m2/g. Adsorption of carbon monoxide and methane on activated carbon of palm shell systems yielded results in the amount of 0.5485 mg/g and 0.0649 mg/g and using commercial activated carbon yielded results in the amount of 0.5480 mg/g and 0.0650 mg/g

  17. Effects of intra-aortic balloon pump on cerebral blood flow during peripheral venoarterial extracorporeal membrane oxygenation support

    PubMed Central

    2014-01-01

    Background The addition of an intra-aortic balloon pump (IABP) during peripheral venoarterial extracorporeal membrane oxygenation (VA ECMO) support has been shown to improve coronary bypass graft flows and cardiac function in refractory cardiogenic shock after cardiac surgery. The purpose of this study was to evaluate the impact of additional IABP support on the cerebral blood flow (CBF) in patients with peripheral VA ECMO following cardiac procedures. Methods Twelve patients (mean age 60.40 ± 9.80 years) received VA ECMO combined with IABP support for postcardiotomy cardiogenic shock after coronary artery bypass grafting. The mean CBF in the bilateral middle cerebral arteries was measured with and without IABP counterpulsation by transcranial Doppler. The patients provided their control values. The mean CBF data were divided into two groups (pulsatile pressure greater than 10 mmHg, P group; pulsatile pressure less than 10 mmHg, N group) based on whether the patients experienced cardiac stun. The mean cerebral blood flow in VA ECMO (IABP turned off) alone and VA ECMO with IABP support were compared using the paired t test. Results All of the patients were successfully weaned from VA ECMO, and eight patients survived to discharge. The addition of IABP to VA ECMO did not change the mean CBF (251.47 ± 79.28 ml/min vs. 251.30 ± 79.47 ml/min, P = 0.96). The mean CBF was higher in VA ECMO alone than in VA ECMO combined with IABP support in the N group (257.68 ± 97.21 ml/min vs. 239.47 ± 95.60, P = 0.00). The addition of IABP to VA ECMO support increased the mean CBF values significantly compared with VA ECMO alone (261.68 ± 82.45 ml/min vs. 244.43 ± 45.85 ml/min, P = 0.00) in the P group. Conclusion These results demonstrate that an IABP significantly changes the CBF during peripheral VA ECMO, depending on the antegrade blood flow by spontaneous cardiac function. The addition of an IABP to VA ECMO support decreased the CBF during cardiac stun, and it increased CBF without cardiac stun. PMID:24766774

  18. A miniature, nongassing electroosmotic pump operating at 0.5 V.

    PubMed

    Shin, Woonsup; Lee, Jong Myung; Nagarale, Rajaram Krishna; Shin, Samuel Jaeho; Heller, Adam

    2011-03-02

    Electroosmotic pumps are arguably the simplest of all pumps, consisting merely of two flow-through electrodes separated by a porous membrane. Most use platinum electrodes and operate at high voltages, electrolyzing water. Because evolved gas bubbles adhere and block parts of the electrodes and the membrane, steady pumping rates are difficult to sustain. Here we show that when the platinum electrodes are replaced by consumed Ag/Ag(2)O electrodes, the pumps operate well below 1.23 V, the thermodynamic threshold for electrolysis of water at 25 °C, where neither H(2) nor O(2) is produced. The pumping of water is efficient: 13 000 water molecules are pumped per reacted electron and 4.8 mL of water are pumped per joule at a flow rate of 0.13 mL min(-1) V(-1) cm(-2), and a flow rate per unit of power is 290 mL min(-1) W(-1). The water is driven by protons produced in the anode reaction 2Ag(s) + H(2)O → Ag(2)O(s) + 2H(+) + 2e(-), traveling through the porous membrane, consumed by hydroxide ions generated in the cathode reaction Ag(2)O(s) + 2 H(2)O + 2e(-) → 2Ag(s) + 2 OH(-). A pump of 2 mm thickness and 0.3 cm(2) cross-sectional area produces flow of 5-30 μL min(-1) when operating at 0.2-0.8 V and 0.04-0.2 mA. Its flow rate can be either voltage or current controlled. The flow rate suffices for the delivery of drugs, such as a meal-associated boli of insulin.

  19. Effects of Change in Tongue Pressure and Salivary Flow Rate on Swallow Efficiency Following Chemoradiation Treatment for Head and Neck Cancer

    PubMed Central

    Rogus-Pulia, Nicole M.; Larson, Charles; Mittal, Bharat B; Pierce, Marge; Zecker, Steven; Kennelty, Korey; Kind, Amy; Connor, Nadine P.

    2016-01-01

    Purpose Patients treated with chemoradiation for head and neck cancer frequently develop dysphagia. Tissue damage to the oral tongue causing weakness and decreases in saliva production may contribute to dysphagia. Yet, effects of these variables on swallowing-related measures are unclear. The purpose of this study was (1) to determine effects of chemoradiation on tongue pressures, as a surrogate for strength, and salivary flow rates and (2) to elucidate relationships among tongue pressures, saliva production, and swallowing efficiency by bolus type. Methods and Materials 21 patients with head and neck cancer treated with chemoradiation were assessed before and after treatment and matched with 21 healthy control participants who did not receive chemoradiation. Each participant was given a questionnaire to rate dysphagia symptoms. Videofluoroscopic evaluation of swallowing was used to determine swallowing efficiency; the Saxon test measured salivary flow rate; and the Iowa Oral Performance Instrument (IOPI) was used for oral tongue maximum and endurance measures. Results Results revealed significantly lower tongue endurance measures for patients post-treatment as compared to controls (p=.012). Salivary flow rates also were lower compared to pre-treatment (p=.000) and controls (p=.000). Simple linear regression analyses showed that change in salivary flow rate was predictive of change in swallow efficiency measures from pre- to post-treatment for 1mL thin liquid (p=.017), 3mL nectar-thick liquid (p=.026), and 3mL standard barium pudding (p=.011) boluses. Conclusions Based on these findings, it appears that chemoradiation treatment affects tongue endurance and salivary flow rate and these changes may impact swallow efficiency. These factors should be considered when planning treatment for dysphagia. PMID:27492408

  20. Foetal blood flow measured using phase contrast cardiovascular magnetic resonance--preliminary data comparing 1.5 T with 3.0 T.

    PubMed

    Tsai-Goodman, Beverly; Zhu, Meng Yuan; Al-Rujaib, Mashael; Seed, Mike; Macgowan, Christopher K

    2015-04-18

    Phase contrast cardiovascular magnetic resonance (PC CMR) has emerged as a clinical tool for blood flow quantification but its use in the foetus has been hampered by the need for gating with the foetal heart beat. The previously described metric optimized gating (MOG) technique has been successfully used to measure foetal blood flow in late gestation foetuses on a 1.5 T CMR magnet. However, there is increasing interest in performing foetal cardiac imaging using 3.0 T CMR. We describe our pilot investigation of foetal blood flow measured using 3.0 T CMR. Foetal blood flows were quantified in 5 subjects at late gestational age (35-38 weeks). Three were normal pregnancies and two were pregnancies with ventricular size discrepancy. Data were obtained at 1.5 T and 3.0 T using a previously described PC CMR protocol. After reconstruction using MOG, blood flow was quantified independently by two observers. Intra- and inter-observer reproducibility of flow measurements at the two field strengths was assessed by Pearson correlation coefficient (R(2)), linear regression and Bland Altman analysis. PC CMR flow measurements were obtained in 36 of 40 target vessels. Strong intra-observer agreement was obtained between measurements at each field strength (R(2) = 0.78, slope = 0.83 ± 0.11), with a mean bias of -1 ml/min/kg and 95% confidence limits of ±71 ml/min/kg. Inter-observer agreement was similarly high for measurements at both 1.5 T (R(2) = 0.86, slope = 0.95 ± 0.13, bias = 6 ± 52 ml/min/kg) and 3.0 T (R(2) = 0.88, slope = 0.94 ± 0.13, bias = 4 ± 47 ml/min/kg). Across all PC CMR measurements, SNR per pixel was expectedly higher at 3.0 T relative to 1.5 T (165 ± 50%). The relative differences in flow measurements between observers were low (range: 4-16%) except for pulmonary blood flow which showed much higher variability at 1.5 T (34%) versus that at 3.0 T (11%). This was attributed to the poorly visualized, small pulmonary vessels at 1.5 T, which made delineation inconsistent between observers. This is the first pilot study to measure foetal blood flow using PC CMR at 3.0 T. The flow data obtained were in good correlation with those measured at 1.5 T, both within and between observers. With increased SNR at 3.0 T, smaller pulmonary vessels were better visualized which improved inter-observer agreement of associated flows.

  1. Measurement of gas yields and flow rates using a custom flowmeter

    USGS Publications Warehouse

    Circone, S.; Kirby, S.H.; Pinkston, J.C.; Stern, L.A.

    2001-01-01

    A simple gas collection apparatus based on the principles of a Torricelli tube has been designed and built to measure gas volume yields and flow rates. This instrument is routinely used to monitor and collect methane gas released during methane hydrate dissociation experiments. It is easily and inexpensively built, operates at ambient pressures and temperatures, and measures gas volumes of up to 7 L to a precision of about 15 ml (about 0.0025 mol). It is capable of measuring gas flow rates varying from more than 103 to less than 10-1 ml/min during gas evolution events that span minutes to several days. We have obtained a highly reproducible hydrate number of n=5.891 with a propagated uncertainty of ??0.020 for synthetic methane hydrate. ?? 2001 American Institute of Physics.

  2. Myocardial Blood Flow in Man: Effects of Coronary Collateral Circulation and Coronary Artery Bypass Surgery

    PubMed Central

    Smith, Sidney C.; Gorlin, Richard; Herman, Michael V.; Taylor, Warren J.; Collins, John J.

    1972-01-01

    The effects of coronary artery bypass graft (CAB) and coronary collaterals (CC) on myocardial blood flow (MBF) were studied in 24 patients undergoing 29 CAB's. MBF after CAB was compared to preexisting MBF by intraoperatively injecting 133xenon via distal CAB with proximal CAB first occluded then open. Pressure gradients across bypassed obstructions were measured. The results were correlated with preoperative coronary arteriograms to determine the effects of CC on MBF and postobstructive perfusion pressures. Mean MBF was increased by CAB from 32±6 (se) ml/min per 100 g (CAB occluded) to 118±13 ml/min per 100 g (CAB open). The 133Xe clearance curves with CAB open were resolved into slow (19±2 ml/min per 100 g) and rapid (133±12 ml/min per 100 g) phases, suggesting that MBF remained heterogeneous after CAB. Vessels with less than 80% stenosis by angiography had pressure gradients less than 20 mm Hg across obstructions, high postobstructive perfusion pressures (75±7 mm Hg), and normal MBF (87±6 ml/min per 100 g) even with CAB occluded. Vessels with greater than 80% stenosis or total occlusion by angiography had significant pressure gradients with marked reduction of postobstructive MBF. No significant difference in postobstructive MBF was found when vessels with CC (21±4 ml/min per 100 g) were compared to those without CC (17±4 ml/min per 100 g) (P > 0.4). These studies demonstrate that (a) mean MBF increased 268% after CAB, (b) heterogeneous MBF persisted after CAB, (c) CC were not associated with significant increases in MBF, and (d) vessels with less than 80% stenosis had less than 20 mm Hg gradient with minimal effect on resting MBF. Images PMID:5056655

  3. Determination of glycated albumin using boronic acid-derived agarose beads on paper-based devices.

    PubMed

    Ko, Euna; Tran, Van-Khue; Geng, Yanfang; Kim, Min Ki; Jin, Ga Hyun; Son, Seong Eun; Hur, Won; Seong, Gi Hun

    2018-01-01

    Self-monitoring of glycated albumin (GA), a useful glycemic marker, is an established method for preventing diabetes complications. Here, the paper-based lateral flow assay devices were developed for the sensitive detection of GA and the total human serum albumin (tHSA) in self-monitoring diabetes patients. Boronic acid-derived agarose beads were packed into a hole on a lateral flow channel. These well-coordinated agarose beads were used to capture GA through specific cis-diol interactions and to enhance the colorimetric signals by concentrating the target molecules. The devices exhibited large dynamic ranges (from 10  μ g/ml to 10 mg/ml for GA and from 10 mg/ml to 50 mg/ml for tHSA) and low detection limits (7.1  μ g/ml for GA and 4.7 mg/ml for tHSA), which cover the range of GA concentration in healthy plasma, which is 0.21-1.65 mg/ml (0.6%-3%). In determining the unknown GA concentrations in two commercial human plasma samples, the relative percentage difference between the values found by a standard ELISA kit and those found by our developed devices was 2.62% and 8.80%, which are within an acceptable range. The measurements of GA and tHSA were completed within 20 min for the total sample-to-answer diagnosis, fulfilling the demand for rapid analysis. Furthermore, the recovery values ranged from 99.4% to 110% in device accuracy tests. These results indicate that the developed paper-based device with boronic acid-derived agarose beads is a promising platform for GA and tHSA detection as applied to self-monitoring systems.

  4. Mean-variance analysis of block-iterative reconstruction algorithms modeling 3D detector response in SPECT

    NASA Astrophysics Data System (ADS)

    Lalush, D. S.; Tsui, B. M. W.

    1998-06-01

    We study the statistical convergence properties of two fast iterative reconstruction algorithms, the rescaled block-iterative (RBI) and ordered subset (OS) EM algorithms, in the context of cardiac SPECT with 3D detector response modeling. The Monte Carlo method was used to generate nearly noise-free projection data modeling the effects of attenuation, detector response, and scatter from the MCAT phantom. One thousand noise realizations were generated with an average count level approximating a typical T1-201 cardiac study. Each noise realization was reconstructed using the RBI and OS algorithms for cases with and without detector response modeling. For each iteration up to twenty, we generated mean and variance images, as well as covariance images for six specific locations. Both OS and RBI converged in the mean to results that were close to the noise-free ML-EM result using the same projection model. When detector response was not modeled in the reconstruction, RBI exhibited considerably lower noise variance than OS for the same resolution. When 3D detector response was modeled, the RBI-EM provided a small improvement in the tradeoff between noise level and resolution recovery, primarily in the axial direction, while OS required about half the number of iterations of RBI to reach the same resolution. We conclude that OS is faster than RBI, but may be sensitive to errors in the projection model. Both OS-EM and RBI-EM are effective alternatives to the EVIL-EM algorithm, but noise level and speed of convergence depend on the projection model used.

  5. HYPERHYDRATION AND PAROTID FLOW IN MAN.

    DTIC Science & Technology

    Parotid fluid was collected without exogenous stimulation from five groups of 25 subjects each. Each group received a different amount of water...under conditions of forced ingestion. The increase in parotid flow rate brought about by water ingestion was highly significant. Doses of 1,000 ml. or

  6. Topical Menthol, Ice, Peripheral Blood Flow, and Perceived Discomfort

    PubMed Central

    Topp, Robert; Ledford, Elizabeth R.; Jacks, Dean E.

    2013-01-01

    Context: Injury management commonly includes decreasing arterial blood flow to the affected site in an attempt to reduce microvascular blood flow and edema and limit the induction of inflammation. Applied separately, ice and menthol gel decrease arterial blood flow, but the combined effects of ice and menthol gel on arterial blood flow are unknown. Objectives: To compare radial artery blood flow, arterial diameter, and perceived discomfort before and after the application of 1 of 4 treatment conditions. Design: Experimental crossover design. Setting: Clinical laboratory. Participants or Other Participants: Ten healthy men, 9 healthy women (mean age = 25.68 years, mean height = 1.73 m, mean weight = 76.73 kg). Intervention(s): Four treatment conditions were randomly applied for 20 minutes to the right forearm of participants on 4 different days separated by at least 24 hours: (1) 3.5 mL menthol gel, (2) 0.5 kg of crushed ice, (3) 3.5 mL of menthol gel and 0.5 kg of crushed ice, or (4) no treatment (control). Main Outcome Measure(s): Using high-resolution ultrasound, we measured right radial artery diameter (cm) and blood flow (mL/min) every 5 minutes for 20 minutes after the treatment was applied. Discomfort with the treatment was documented using a 1-to-10 intensity scale. Results: Radial artery blood flow decreased (P < .05) from baseline in the ice (−20% to −24%), menthol (−17% to −24%), and ice and menthol (−36% to −39%) treatments but not in the control (3% to 9%) at 5, 10, and 15 minutes. At 20 minutes after baseline, only the ice (−27%) and combined ice and menthol (−38%) treatments exhibited reductions in blood flow (P < .05). Discomfort was less with menthol than with the ice treatment at 5, 10, and 20 minutes after application (P < .05). Arterial diameter and heart rate did not change. Conclusions: The application of 3.5 mL of menthol was similar to the application of 0.5 kg of crushed ice in reducing peripheral blood flood. Combining crushed ice with menthol appeared to have an additive effect on reducing blood flow. PMID:23672386

  7. Overdrainage and shunt technology. A critical comparison of programmable, hydrostatic and variable-resistance valves and flow-reducing devices.

    PubMed

    Aschoff, A; Kremer, P; Benesch, C; Fruh, K; Klank, A; Kunze, S

    1995-04-01

    When vertical body position is simulated, conventional differential pressure valves show an absolutely unphysiological flow, which is 2-170 times the normal liquor production rate. Although this is compensated in part by the resistance of the silicon tubes, which may produce up to 94% of the resistance of the complete shunt system, a negative intracranial pressure (ICP) of up to 30-44 cmH2O is an unavoidable consequence, which can be followed by subdural hematomas, slit ventricles, and other well-known complications. Modern shunt technology offers programmable, hydrostatic, and "flow-controlled" valves and anti-siphon devices; we have tested 13 different designs from 7 manufacturers (56 specimens), using the "Heidelberg Valve Test Inventory" with 16 subtests. "Programmable" valves reduce, but cannot exclude, unphysiological flow rates: even in the highest position and in combination with a standard catheter typical programmable Medos-Hakim valves allow a flow of 93-232 ml/h, Sophy SU-8-valves 86-168 ml/h with 30 cmH2O. The effect of hydrostatic valves (Hakim-Lumbar, Chhabra) can be inactivated by movements of daily life. The weight of the metal balls in most valves was too low for adequate flow reduction. Antisiphon devices are highly dependent on external, i.e. subcutaneous, pressure which has unpredictable influences on shunt function, and clinically is sometimes followed by shunt insufficiency. Two new Orbis-Sigma valves showed relatively physiological flow rates even when the vertical position (30 cmH2O) was simulated. One showed an insufficient flow (5.7 ml/h), and one was primarily obstructed. These have by far the smallest outlet of all valves. Additionally, the ruby pin tends to stick. Therefore, a high susceptibility to obliterations and blockade is unavoidable. Encouraging results obtained in pediatric patients contrast with disappointing experiences in some German and Swedish hospitals, which suggests that our laboratory findings are confirmed by clinical results. The concept of strict flow limitation seems to be inadaequate for adult patients, who need a relatively high flow during (nocturnal) ICP crises. The problem of shunt overdrainage remains unsolved.

  8. Oral sugar clearance and root caries prevalence in rheumatic patients with dry mouth symptoms.

    PubMed

    Risheim, H; Arneberg, P; Birkhed, D

    1992-01-01

    The relationship between root caries, oral sugar clearance, salivary flow rate, and salivary counts of mutans streptococci, lactobacilli and candida has been studied in a group of 22 rheumatic patients (age range 40-72 years). The study group comprised all subjects volunteering for a clinical trial on relief of dry mouth symptoms. The median salivary flow was 0.09 ml/min at rest and 0.9 ml/min during chewing stimulation. The median sugar clearance time was about 5 min in the sublingual area and 16 min in the lower buccal vestibule. For subjects with 0-2 root caries lesions the clearance time at both sites was shorter than for subjects with 3 or more lesions (p < 0.05). A long oral clearance time was significantly correlated with age, root caries (DS and DFS), low resting salivary flow, and high salivary counts of mutans streptococci. It is concluded that root caries in rheumatic patients with low salivary flow is significantly related to oral sugar clearance time.

  9. Two-Dimensional Automatic Measurement for Nozzle Flow Distribution Using Improved Ultrasonic Sensor

    PubMed Central

    Zhai, Changyuan; Zhao, Chunjiang; Wang, Xiu; Wang, Ning; Zou, Wei; Li, Wei

    2015-01-01

    Spray deposition and distribution are affected by many factors, one of which is nozzle flow distribution. A two-dimensional automatic measurement system, which consisted of a conveying unit, a system control unit, an ultrasonic sensor, and a deposition collecting dish, was designed and developed. The system could precisely move an ultrasonic sensor above a pesticide deposition collecting dish to measure the nozzle flow distribution. A sensor sleeve with a PVC tube was designed for the ultrasonic sensor to limit its beam angle in order to measure the liquid level in the small troughs. System performance tests were conducted to verify the designed functions and measurement accuracy. A commercial spray nozzle was also used to measure its flow distribution. The test results showed that the relative error on volume measurement was less than 7.27% when the liquid volume was 2 mL in trough, while the error was less than 4.52% when the liquid volume was 4 mL or more. The developed system was also used to evaluate the flow distribution of a commercial nozzle. It was able to provide the shape and the spraying width of the flow distribution accurately. PMID:26501288

  10. Prospective phase II study of the efficacy of transcutaneous electrical nerve stimulation in post-radiation patients.

    PubMed

    Vijayan, A; Asha, M L; Babu, S; Chakraborty, S

    2014-12-01

    To evaluate the effectiveness of transcutaneous electrical nerve stimulation (TENS) delivered using an extra-oral device in patients with radiation-induced xerostomia. Thirty oral cavity and oropharyngeal cancer patients post-adjuvant (n = 26) or definitive radiotherapy (n = 4) were enrolled in this study. The TENS electrode pads were placed externally on the skin overlying the parotid glands. Unstimulated whole saliva was collected for 5 min into graduated tubes using the low forced spitting method. The TENS unit was then activated and stimulated saliva was collected for an additional 5 min. The difference between unstimulated and stimulated saliva output was measured using the paired t-test. Linear regression was used to determine factors significantly influencing the improvement in salivary output. Twenty-nine of 30 patients showed increased saliva flow during stimulation. A statistically significant improvement in saliva production (P < 0.05) during stimulation was noted. The mean unstimulated saliva flow was 0.056 ml/min and the mean stimulated saliva flow was 0.12 ml/min with a median increase of 0.06 ml/min. The interval to the application of TENS after radiotherapy significantly influenced the improvement in salivary flow. Extra-oral application of TENS is effective in increasing the whole salivary flow in most of the post-radiated oral cavity/oropharyngeal cancer patients with xerostomia. TENS therapy may be useful as an effective supportive treatment modality in post-radiated oral cancer patients. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  11. Counterrotating Propulsive System.

    DTIC Science & Technology

    1981-12-01

    Propellers ," David Taylor Model Basin Report 1342, February 1960. 7. Miller, M.L., " Experimental Determination of Unsteady Forces on Counter- rotating...21. Miller, M.L., " Experimental Determination of Unsteady Forces on Contra- rotating Propellers for Application to Torpedoes," David W. Taylor Naval...pair of counterrotating propellers in a uniform in- flow is given by Reference [14] with the same results. On the

  12. Measurement of glomerular filtration rate, renal plasma flow, and endogenous creatinine clearance in cheetahs (Acinonyx jubatus jubatus).

    PubMed

    Holder, Erin Hall; Citino, Scott B; Businga, Nancy; Cartier, Leslie; Brown, Scott A

    2004-06-01

    Glomerular filtration rate (GFR), renal plasma flow (RPF), and the endogenous creatinine clearance (CCr) rate were determined in 13 captive cheetahs, Acinonyx jubatus jubatus (seven females and six males, 1.5-7.5 yr of age, x = 5.02 yr), during general anesthesia with Telazol and isoflurane by measuring the urinary clearances of inulin, para-aminohipppuric acid, and endogenous creatinine, respectively. Methods to determine GFR, RPF, and endogenous CCr in captive cheetahs were evaluated, and the relationship between GFR and CCr for this species was determined. The GFR and the RPF were stable during the procedure, with mean values of 1.59+/-0.17 ml/min/kg body weight and 5.12+/-1.15 ml/min/kg body weight, respectively. Although the mean value for CCr (1.47+/-0.20 ml/min/kg body weight) was significantly less than the corresponding value for GFR, the mean difference (0.11+/-0.02 ml/min/kg weight) between the two measurements was slight, and the values were highly correlated (R2 = 0.928; P < 0.0001). The measurement of CCr in cheetahs should provide a reliable estimate of GFR, facilitating the early detection of renal disease in this species.

  13. Using Asymmetric Flow Field-Flow Fractionation (AF4) to Determine C60 Colloidal Size Distributions

    EPA Science Inventory

    The formation of aqueous fullerene suspensions by solvent exchange, sonication, or extended mixing in water is widely reported. Commonly used methods for determining the size of these aggregates rely on static and dynamic light scattering, electron microscopy (EM), or atomic forc...

  14. Protective activity of Cynara scolymus L. leaf extract against chemically induced complex genomic alterations in CHO cells.

    PubMed

    Jacociunas, Laura Vicedo; de Andrade, Heloisa Helena Rodrigues; Lehmann, Mauricio; Pedersini, Larissa Wölfle; Ferraz, Alexandre de Barros Falcão; da Silva, Juliana; Dihl, Rafael Rodrigues

    2013-09-15

    Cynara scolymus L., popularly known as artichoke, has been widely used in traditional medicine as an herbal medicament for therapeutic purposes. The study aimed at assessing the protective activity of Cynara scolymus leaf extract (LE) against DNA lesions induced by the alkylating agent ethylmethnesulphonate (EMS) in Chinese hamster ovary cells (CHO). The ability of C. scolymus L. LE to modulate the mutagenicity of EMS was examined using the cytokinesis block micronucleus (CBMN) cytome assay in three antigenotoxic protocols, pre- post- and simultaneous treatments. In the pre-treatment, C. scolymus L. LE reduced the frequencies of MNi and NBUDs induced by EMS in the lower concentration. In contrast, at the highest concentration (5 mg/ml) artichoke enhanced the frequency of MNi, potentiating EMS genotoxicity. In the simultaneous treatment only the induction of MNi was repressed by the exposure of cells to C. scolymus L. LE. No modification in genotoxicity was observed in LE post-treatment. The results obtained in this study suggest that lower concentrations of artichoke prevent chemically induced genomic damage in mammalian cells. In this context, the protective activity of C. scolymus L. could be associated to its constitutive antioxidants compounds. Copyright © 2013 Elsevier GmbH. All rights reserved.

  15. Prevalence of serum celiac antibodies in a multiracial Asian population--a first study in the young Asian adult population of Malaysia.

    PubMed

    Yap, Theresa Wan-Chen; Chan, Weng-Kai; Leow, Alex Hwong-Ruey; Azmi, Ahmad Najib; Loke, Mun-Fai; Vadivelu, Jamuna; Goh, Khean-Lee

    2015-01-01

    Celiac disease (CD) is an immune-mediated disorder induced by the ingestion of gluten in genetically susceptible persons. The prevalence of CD in Malaysia is unknown. We aim to determine the seroprevalence of CD antibodies and also investigate the correlation between H. pylori infection and CD in the young and healthy multiracial Malaysian population. Healthy young adult volunteers between the ages of 18-30 years were consecutively recruited from June 2012 to May 2014 at the University of Malaya Medical Centre (UMMC), Kuala Lumpur. Serum samples from all the participants were tested for anti-gliadin antibody immunoglobulin A/immunoglobulin G (IgA/IgG) and anti-tissue transglutaminase antibody (tTG) IgA/IgG. Samples positive for both anti-gliadin and anti-tTG were further validated for anti-human endomysial IgA antibodies (EmA). Serological diagnosis of CD was made when anti-gliadin, anti-tTG and anti-EmA were positive. 562 qualified participants with mean age 24 ± 2.4 years old were recruited into our study. CD was found in 7 participants where most of them were asymptomatic and unaware of their CD status. The median of anti-gliadin and anti-tTG IgA/IgG value was 38.2 U/ml (interquartile range, 28.3-60.4 U/ml) and 49.2 U/ml (interquartile range, 41.1-65.9 U/ml), respectively. Seroprevalence of CD antibodies was 1.9% (6 out of 324) in female while only 0.4% (1 out of 238) in male. Seroprevalence among Malay was 0.8% (2 of 236), Chinese was 1.7% (3 of 177) and Indian was 1.3% (2 of 149). Overall, seroprevalence of CD antibodies in healthy asymptomatic adults in the Malaysian population was 1.25% (95% CI, 0.78%-1.72%). No significant relationship was discovered between CD and H. pylori infection. The seroprevalence of CD antibodies in healthy young adults in the Malaysian population was 1.25% (1 in 100). CD is underdiagnosed and it could be a much greater problem in Malaysia than previously thought.

  16. Blood flow regulation and oxygen uptake during high-intensity forearm exercise.

    PubMed

    Nyberg, S K; Berg, O K; Helgerud, J; Wang, E

    2017-04-01

    The vascular strain is very high during heavy handgrip exercise, but the intensity and kinetics to reach peak blood flow, and peak oxygen uptake, are uncertain. We included 9 young (25 ± 2 yr) healthy males to evaluate blood flow and oxygen uptake responses during continuous dynamic handgrip exercise with increasing intensity. Blood flow was measured using Doppler-ultrasound, and venous blood was drawn from a deep forearm vein to determine arteriovenous oxygen difference (a-vO 2diff ) during 6-min bouts of 60, 80, and 100% of maximal work rate (WR max ), respectively. Blood flow and oxygen uptake increased ( P < 0.05) from 60%WR max [557 ± 177(SD) ml/min; 56.0 ± 21.6 ml/min] to 80%WR max (679 ± 190 ml/min; 70.6 ± 24.8 ml/min), but no change was seen from 80%WR max to 100%WR max Blood velocity (49.5 ± 11.5 to 58.1 ± 11.6 cm/s) and brachial diameter (0.49 ± 0.05 to 0.50 ± 0.06 cm) showed concomitant increases ( P < 0.05) with blood flow from 60% to 80%WR max, whereas no differences were observed in a-vO 2diff Shear rate also increased ( P < 0.05) from 60% (822 ± 196 s -1 ) to 80% (951 ± 234 s -1 ) of WR max The mean response time (MRT) was slower ( P < 0.05) for blood flow (60%WR max 50 ± 22 s; 80%WR max 51 ± 20 s; 100%WR max 51 ± 23 s) than a-vO 2diff (60%WR max 29 ± 9 s; 80%WR max 29 ± 5 s; 100%WR max 20 ± 5 s), but not different from oxygen uptake (60%WR max 44 ± 25 s; 80%WR max 43 ± 14 s; 100%WR max 41 ± 32 s). No differences were observed in MRT for blood flow or oxygen uptake with increased exercise intensity. In conclusion, when approaching maximal intensity, oxygen uptake appeared to reach a critical level at ~80% of WR max and be regulated by blood flow. This implies that high, but not maximal, exercise intensity may be an optimal stimulus for shear stress-induced small muscle mass training adaptations. NEW & NOTEWORTHY This study evaluated blood flow regulation and oxygen uptake during small muscle mass forearm exercise with high to maximal intensity. Despite utilizing only a fraction of cardiac output, blood flow reached a plateau at 80% of maximal work rate and regulated peak oxygen uptake. Furthermore, the results revealed that muscle contractions dictated bulk oxygen delivery and yielded three times higher peak blood flow in the relaxation phase compared with mean values. Copyright © 2017 the American Physiological Society.

  17. Stability of carotid artery under steady-state and pulsatile blood flow: a fluid-structure interaction study.

    PubMed

    Saeid Khalafvand, Seyed; Han, Hai-Chao

    2015-06-01

    It has been shown that arteries may buckle into tortuous shapes under lumen pressure, which in turn could alter blood flow. However, the mechanisms of artery instability under pulsatile flow have not been fully understood. The objective of this study was to simulate the buckling and post-buckling behaviors of the carotid artery under pulsatile flow using a fully coupled fluid-structure interaction (FSI) method. The artery wall was modeled as a nonlinear material with a two-fiber strain-energy function. FSI simulations were performed under steady-state flow and pulsatile flow conditions with a prescribed flow velocity profile at the inlet and different pressures at the outlet to determine the critical buckling pressure. Simulations were performed for normal (160 ml/min) and high (350 ml/min) flow rates and normal (1.5) and reduced (1.3) axial stretch ratios to determine the effects of flow rate and axial tension on stability. The results showed that an artery buckled when the lumen pressure exceeded a critical value. The critical mean buckling pressure at pulsatile flow was 17-23% smaller than at steady-state flow. For both steady-state and pulsatile flow, the high flow rate had very little effect (<5%) on the critical buckling pressure. The fluid and wall stresses were drastically altered at the location with maximum deflection. The maximum lumen shear stress occurred at the inner side of the bend and maximum tensile wall stresses occurred at the outer side. These findings improve our understanding of artery instability in vivo.

  18. Stability of Carotid Artery Under Steady-State and Pulsatile Blood Flow: A Fluid–Structure Interaction Study

    PubMed Central

    Saeid Khalafvand, Seyed; Han, Hai-Chao

    2015-01-01

    It has been shown that arteries may buckle into tortuous shapes under lumen pressure, which in turn could alter blood flow. However, the mechanisms of artery instability under pulsatile flow have not been fully understood. The objective of this study was to simulate the buckling and post-buckling behaviors of the carotid artery under pulsatile flow using a fully coupled fluid–structure interaction (FSI) method. The artery wall was modeled as a nonlinear material with a two-fiber strain-energy function. FSI simulations were performed under steady-state flow and pulsatile flow conditions with a prescribed flow velocity profile at the inlet and different pressures at the outlet to determine the critical buckling pressure. Simulations were performed for normal (160 ml/min) and high (350 ml/min) flow rates and normal (1.5) and reduced (1.3) axial stretch ratios to determine the effects of flow rate and axial tension on stability. The results showed that an artery buckled when the lumen pressure exceeded a critical value. The critical mean buckling pressure at pulsatile flow was 17–23% smaller than at steady-state flow. For both steady-state and pulsatile flow, the high flow rate had very little effect (<5%) on the critical buckling pressure. The fluid and wall stresses were drastically altered at the location with maximum deflection. The maximum lumen shear stress occurred at the inner side of the bend and maximum tensile wall stresses occurred at the outer side. These findings improve our understanding of artery instability in vivo. PMID:25761257

  19. Characterization of Chronic Aortic and Mitral Regurgitation Undergoing Valve Surgery Using Cardiovascular Magnetic Resonance.

    PubMed

    Polte, Christian L; Gao, Sinsia A; Johnsson, Åse A; Lagerstrand, Kerstin M; Bech-Hanssen, Odd

    2017-06-15

    Grading of chronic aortic regurgitation (AR) and mitral regurgitation (MR) by cardiovascular magnetic resonance (CMR) is currently based on thresholds, which are neither modality nor quantification method specific. Accordingly, this study sought to identify CMR-specific and quantification method-specific thresholds for regurgitant volumes (RVols), RVol indexes, and regurgitant fractions (RFs), which denote severe chronic AR or MR with an indication for surgery. The study comprised patients with moderate and severe chronic AR (n = 38) and MR (n = 40). Echocardiography and CMR was performed at baseline and in all operated AR/MR patients (n = 23/25) 10 ± 1 months after surgery. CMR quantification of AR: direct (aortic flow) and indirect method (left ventricular stroke volume [LVSV] - pulmonary stroke volume [PuSV]); MR: 2 indirect methods (LVSV - aortic forward flow [AoFF]; mitral inflow [MiIF] - AoFF). All operated patients had severe regurgitation and benefited from surgery, indicated by a significant postsurgical reduction in end-diastolic volume index and improvement or relief of symptoms. The discriminatory ability between moderate and severe AR was strong for RVol >40 ml, RVol index >20 ml/m 2 , and RF >30% (direct method) and RVol >62 ml, RVol index >31 ml/m 2 , and RF >36% (LVSV-PuSV) with a negative likelihood ratio ≤ 0.2. In MR, the discriminatory ability was very strong for RVol >64 ml, RVol index >32 ml/m 2 , and RF >41% (LVSV-AoFF) and RVol >40 ml, RVol index >20 ml/m 2 , and RF >30% (MiIF-AoFF) with a negative likelihood ratio < 0.1. In conclusion, CMR grading of chronic AR and MR should be based on modality-specific and quantification method-specific thresholds, as they differ largely from recognized guideline criteria, to assure appropriate clinical decision-making and timing of surgery. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Geochemistry and petrogenesis of lava flows around Linga, Chhindwara area in the Eastern Deccan Volcanic Province (EDVP), India

    NASA Astrophysics Data System (ADS)

    Ganguly, Sohini; Ray, Jyotisankar; Koeberl, Christian; Saha, Abhishek; Thöni, Martin; Balaram, V.

    2014-09-01

    Based on systematic three-tier arrangement of vesicles, entablature and columnar joints, three distinct quartz normative tholeiitic lava flows (I, II and III) were recognized in the area around Linga, in the Eastern Deccan Volcanic Province (EDVP). Each of the flows exhibits intraflow chemical variations marked by high Mg#-low Ti, and low Mg#-high Ti contents. The MgO (4.27-7.74 wt.%), Mg# (23.45-41.89) and Zr (161.5-246.3 ppm) of Linga flows suggest an evolved chemistry marked by fractional crystallization and crustal contamination processes. Positive Rb and Th anomalies, negative Nb anomalies, relative enrichment of LILE-LREE with respect to Nb, Nb/Th:3.71-6.77 indicate crustal contamination of magma by continental materials through magma-crust interaction during melt migration and contributions from sub-continental lithospheric mantle (SCLM). Negative K, Sr and Ti anomalies corroborate an intracontinental, rift-controlled tectonic setting for the genesis and evolution of Linga basalts. Chondrite-normalized REE patterns reflect low HREE abundances and prominent LREE/HREE, MREE/HREE fractionation thereby pointing towards partial melting of garnet peridotite mantle source. Nb, Zr, Y variations suggest 10-15% partial melting of mantle source for the derivation of parent tholeiitic melt that suffered crystal fractionation of phenocrystal phases and subsequent liquid immiscibility. Critical evaluation of Srinitial and Ndinitial (65 Ma) isotopic compositions (87Sr/86Srinitial between 0.705656 and 0.706980 and 143Nd/144Ndinitial between 0.512523 and 0.512598) suggests that these basalts were derived from an enriched mantle (∼EM I-EM II) source. The εSr (21.84-41.27) and εNd (-0.28 to 1.10) isotopic signatures defined by higher εSr and lower εNd fingerprint a plume-related source. Positive and negative values of εNd indicate an isotopically heterogeneous mantle source marked by mixing of depleted (DM) and enriched mantle (EM I-EM II) components at the source region and together with 87Sr/86Srinitial ranging from 0.705656 to 0.706980 suggest two stage contamination of parent magma which is much similar to that of Poladpur, Toranmal, Mhow, Chikaldara flows. Ba/Y versus 87Sr/86Sr and Nb/Y versus Rb/Y variations show an Ambenali-Poladpur contamination trend for the Linga basalts thereby suggesting the role of upper continental granitic crust as the contaminant of these flows through magma-crust interaction during melt migration. The lava flows of Linga are geochemically correlatable with the Poladpur flows of southwestern and Toranmal flows of northern Deccan and show genetic coherence with the basalts of Jabalpur, Seoni, Chakhla-Delakhari of eastern Deccan.

  1. Renal sympathetic denervation increases renal blood volume per cardiac cycle: a serial magnetic resonance imaging study in resistant hypertension.

    PubMed

    Delacroix, Sinny; Chokka, Ramesh G; Nelson, Adam J; Wong, Dennis T; Sidharta, Samuel; Pederson, Stephen M; Rajwani, Adil; Nimmo, Joanne; Teo, Karen S; Worthley, Stephen G

    2017-01-01

    Preclinical studies have demonstrated improvements in renal blood flow after renal sympathetic denervation (RSDN); however, such effects are yet to be confirmed in patients with resistant hypertension. Herein, we assessed the effects of RSDN on renal artery blood flow and diameter at multiple time points post-RSDN. Patients (n=11) with systolic blood pressures ≥160 mmHg despite taking three or more antihypertensive medications at maximum tolerated dose were recruited into this single-center, prospective, non-blinded study. Magnetic resonance imaging indices included renal blood flow and renal artery diameters at baseline, 1 month and 6 months. In addition to significant decreases in blood pressures ( p <0.0001), total volume of blood flow per cardiac cycle increased by 20% from 6.9±2 mL at baseline to 8.4±2 mL ( p =0.003) at 1 month and to 8.0±2 mL ( p =0.04) 6 months post-procedure, with no changes in the renal blood flow. There was a significant decrease in renal artery diameters from 7±2 mm at baseline to 6±1 mm ( p =0.03) at 1 month post-procedure. This decrease was associated with increases in maximum velocity of blood flow from 73±20 cm/s at baseline to 78±19 cm/s at 1 month post-procedure. Notably, both parameters reverted to 7±2 mm and 72±18 cm/s, respectively, 6 months after procedure. RSDN improves renal physiology as evidenced by significant improvements in total volume of blood flow per cardiac cycle. Additionally, for the first time, we identified a transient decrease in renal artery diameters immediately after procedure potentially caused by edema and inflammation that reverted to baseline values 6 months post-procedure.

  2. Evaluation on nitrogen oxides and nanoparticle removal and nitrogen monoxide generation using a wet-type nonthermal plasma reactor

    NASA Astrophysics Data System (ADS)

    Takehana, Kotaro; Kuroki, Tomoyuki; Okubo, Masaaki

    2018-05-01

    Nitrogen oxides (NOx) emitted from power plants and combustion sources cause air pollution problems. Selective catalytic reduction technology is remarkably useful for NOx removal. However, there are several drawbacks such as preparation of reducing agents, usage of harmful heavy metals, and higher cost. On the other hand, trace NO is a vasodilator agent and employed in inhalation therapies for treating pulmonary hypertension in humans. Considering these factors, in the present study, a wet-type nonthermal plasma reactor, which can control NOx and nanoparticle emissions and generate NO, is investigated. The fundamental characteristics of the reactor are investigated. First, the experiment of nanoparticle removal is carried out. Collection efficiencies of over 99% are achieved for nanoparticles at 50 and 100 ml min‑1 of liquid flow rates. Second, experiments of NOx removal under air atmosphere and NOx generation under nitrogen atmosphere are carried out. NOx-removal efficiencies of over 95% under the air plasma are achieved in 50–200 ml min‑1 liquid flow rates. Moreover, under nitrogen plasma, NOx is generated, of which the major portion is NO. For example, NO concentration is 25 ppm, while NOx concentration is 31 ppm at 50 ml min‑1 liquid flow rate. Finally, experiments of NO generation under the nitrogen atmosphere with or without flowing water are carried out. When water flows on the inner surface of the reactor, approximately 14 ppm of NO is generated. Therefore, NO generation requires flowing water. It is considered that the reaction of N and OH, which is similar to the extended Zeldovich mechanism, could occur to induce NO formation. From these results, it is verified that the wet-type plasma reactor is useful for NOx removal and NO generation under nitrogen atmosphere with flowing water.

  3. Ultrasound-guided axillary brachial plexus block versus local infiltration anesthesia for arteriovenous fistula creation at the forearm for hemodialysis in patients with chronic renal failure.

    PubMed

    Nofal, W H; El Fawal, S M; Shoukry, A A; Sabek, Eas; Malak, Wfa

    2017-01-01

    The primary failure rate for arteriovenous fistula (AVF) creation under local anesthesia for hemodialysis is about 30%. Axillary brachial plexus block (BPB) may improve blood flow through blood vessels used in fistula creation; it may improve the AVF blood flow and thus may reduce the primary failure rate after 3 months. Hundred and forty patients with chronic renal failure scheduled for AVF creation for hemodialysis were divided into two equal groups; Group 1 (AxBP-G) received ultrasound (US) guided axillary BPB, and Group 2 (LI-G) received local infiltration. We recorded the measurements of the brachial and radial arteries before and after anesthesia and the AVF blood flow in both groups at three different time points. Furthermore, the primary failure rate was recorded in each group and compared. After anesthesia, the mean radial artery blood flow in the AxBP-group was 3.52 ml/min more than the LI-group, and the brachial artery diameter was also 0.68 mm more than in the LI-group, both differences were statistically significant ( P < 0.05). There were significant increases ( P < 0.05) in the AVF blood flow in the AxBP-group more than the LI-group with mean differences of 29.6, 69.8, and 27.2 ml/min at 4 h, 1 week, and 3 months, respectively. The overall mean of AVF blood flow was 42.21 ml/min more in the AxBP group than the LI-group a difference which is statistically significant ( P < 0.001). The primary failure rate was 17% in the AxBP group versus 30% in the LI-group; however, this difference is not significant statistically ( P = 0.110). The US-guided axillary block increases AVF blood flow significantly more than local infiltration and nonsignificantly decreases the primary failure rate of the AVF after 3 months.

  4. Total nitrogen and total phosphorus removal from brackish aquaculture wastewater using effective microorganism

    NASA Astrophysics Data System (ADS)

    Mohamad, K. A.; Mohd, S. Y.; Sarah, R. S.; Mohd, H. Z.; Rasyidah, A.

    2017-09-01

    Aquaculture is one of dominant food based industry in the world with 8.3% annual growth rate and its development had led to adverse effect on the environment. High nutrient production in form of nitrogenous compound and phosphorus contributed to environmental deterioration such as eutrophication and toxicity to the industry. Usage of Effective Microorganism (EM), one of the biological approaches to remove Total Nitrogen (TN) and Total Phosphorus (TP) in aquaculture pond was proposed. Samples were obtained from the Sea Bass intensive brackish aquaculture wastewater (AW) from fish farm at Juru, Penang and the parameters used to measure the removal of nitrogenous compounds include, pH, EM dosage, shaking, contact time and optimum variable conditions. From the study, for effective contact time, day 6 is the optimum contact time for both TN and TP with 99.74% and 62.78% removal respectively while in terms of optimum pH, the highest TN removal was at pH 7 with 66.89 %. The optimum dosage of EM is 1.5 ml with ratio 1:166 for 81.5 % TN removal was also found appropriate during the experiment. At varied optimum conditions of EM, the removal efficiency of TN and TP were 81.53% and 38.94% respectively while the removal mechanism of TN was highly dependent on the decomposition rate of specific bacteria such as Nitrobacter bacteria, Yeast and Bacillus Subtilis sp. The study has established the efficacy of EM's ability to treat excessive nutrient of TN and TP from AW.

  5. Surveillance of hemodialysis vascular access with ultrasound vector flow imaging

    NASA Astrophysics Data System (ADS)

    Brandt, Andreas H.; Olesen, Jacob B.; Hansen, Kristoffer L.; Rix, Marianne; Jensen, Jørgen A.; Nielsen, Michael B.

    2015-03-01

    The aim of this study was prospectively to monitor the volume flow in patients with arteriovenous fistula (AVF) with the angle independent ultrasound technique Vector Flow Imaging (VFI). Volume flow values were compared with Ultrasound dilution technique (UDT). Hemodialysis patients need a well-functioning vascular access with as few complications as possible and preferred vascular access is an AVF. Dysfunction due to stenosis is a common complication, and regular monitoring of volume flow is recommended to preserve AVF patency. UDT is considered the gold standard for volume flow surveillance, but VFI has proven to be more precise, when performing single repeated instantaneous measurements. Three patients with AVF were monitored with UDT and VFI monthly for five months. A commercial ultrasound scanner with a 9 MHz linear array transducer with integrated VFI was used to obtain data. UDT values were obtained with Transonic HD03 Flow-QC Hemodialysis Monitor. Three independent measurements at each scan session were obtained with UDT and VFI each month. Average deviation of volume flow between UDT and VFI was 25.7 % (Cl: 16.7% to 34.7%) (p= 0.73). The standard deviation for all patients, calculated from the mean variance of each individual scan sessions, was 199.8 ml/min for UDT and 47.6 ml/min for VFI (p = 0.002). VFI volume flow values were not significantly different from the corresponding estimates obtained using UDT, and VFI measurements were more precise than UDT. The study indicates that VFI can be used for surveillance of volume flow.

  6. Item-Based Top-N Recommendation Algorithms

    DTIC Science & Technology

    2003-01-20

    basket of items, utilized by many e-commerce sites, cannot take advantage of pre-computed user-to-user similarities. Finally, even though the...not discriminate between items that are present in frequent itemsets and items that are not, while still maintaining the computational advantages of...453219 0.02% 7.74 ccard 42629 68793 398619 0.01% 9.35 ecommerce 6667 17491 91222 0.08% 13.68 em 8002 1648 769311 5.83% 96.14 ml 943 1682 100000 6.31

  7. Electromigration in Cu(Al) and Cu(Mn) damascene lines

    NASA Astrophysics Data System (ADS)

    Hu, C.-K.; Ohm, J.; Gignac, L. M.; Breslin, C. M.; Mittal, S.; Bonilla, G.; Edelstein, D.; Rosenberg, R.; Choi, S.; An, J. J.; Simon, A. H.; Angyal, M. S.; Clevenger, L.; Maniscalco, J.; Nogami, T.; Penny, C.; Kim, B. Y.

    2012-05-01

    The effects of impurities, Mn or Al, on interface and grain boundary electromigration (EM) in Cu damascene lines were investigated. The addition of Mn or Al solute caused a reduction in diffusivity at the Cu/dielectric cap interface and the EM activation energies for both Cu-alloys were found to increase by about 0.2 eV as compared to pure Cu. Mn mitigated and Al enhanced Cu grain boundary diffusion; however, no significant mitigation in Cu grain boundary diffusion was observed in low Mn concentration samples. The activation energies for Cu grain boundary diffusion were found to be 0.74 ± 0.05 eV and 0.77 ± 0.05 eV for 1.5 μm wide polycrystalline lines with pure Cu and Cu (0.5 at. % Mn) seeds, respectively. The effective charge number in Cu grain boundaries Z*GB was estimated from drift velocity and was found to be about -0.4. A significant enhancement in EM lifetimes for Cu(Al) or low Mn concentration bamboo-polycrystalline and near-bamboo grain structures was observed but not for polycrystalline-only alloy lines. These results indicated that the existence of bamboo grains in bamboo-polycrystalline lines played a critical role in slowing down the EM-induced void growth rate. The bamboo grains act as Cu diffusion blocking boundaries for grain boundary mass flow, thus generating a mechanical stress-induced back flow counterbalancing the EM force, which is the equality known as the "Blech short length effect."

  8. Continuous xylanase production with Aspergillus nidulans under pyridoxine limitation using a trickle bed reactor.

    PubMed

    Müller, Michael; Prade, Rolf A; Segato, Fernando; Atiyeh, Hasan K; Wilkins, Mark R

    2015-01-01

    A trickle bed reactor (TBR) with recycle was designed and tested using Aspergillus nidulans with a pyridoxine marker and over-expressing/secreting recombinant client xylanase B (XynB). The pyridoxine marker prevented the fungus from synthesizing its own pyridoxine and fungus was unable to grow when no pyridoxine was present in the medium; however, enzyme production was unaffected. Uncontrolled mycelia growth that led to clogging of the TBR was observed when fungus without a pyridoxine marker was used for XynB production. Using the fungus with pyridoxine marker, the TBR was operated continuously for 18 days and achieved a XynB output of 41 U/ml with an influent and effluent flow rate of 0.5 ml/min and a recycle flow rate of 56 ml/min. Production yields in the TBR were 1.4 times greater than a static tray culture and between 1.1 and 67 times greater than yields for SSF enzyme production stated in the literature. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. N-bromosuccinimide-fluorescein based sensitive flow-injection chemiluminescence determination of phenformin.

    PubMed

    Wang, Zhouping; Zhang, Zhujun; Fu, Zhifeng; Fang, Luqiu; Zhang, Xiao

    2004-02-01

    A novel and highly sensitive method for the determination of phenformin over the range of 6 x 10(-9) - 1 x 10(-5) g ml(-1) in pharmaceutical formulations with flow-injection chemiluminescence (CL) detection is proposed. The method is based on the CL produced during the oxidation of N-bromosuccinimide (NBS) in an alkaline medium in the presence of fluorescein as an effective energy transfer agent. The use of cetyltrimethylammonium bromide (CTAB) as a sensitizer enhances the signal magnitude by about 100 times. The detection limit is 2 x 10(-9) g ml(-1) (3sigma) with a relative standard deviation of 2.3% (n = 11) at 1 x 10(-7) g ml(-1) phenformin. Ninety samples can be determined per hour. The method was evaluated by carrying out a recovery study and by the analysis of commercial formulations. The obtained results compared well with those by an official method, and demonstrated good accuracy and precision. The possible CL mechanism of the proposed system was also briefly analyzed.

  10. The search for an endogenous activator.

    PubMed Central

    Gekowski, K. M.; Atkins, E.

    1985-01-01

    Certain febrile diseases are unaccompanied by infection or apparent hypersensitivity. In myocardial infarction or pulmonary embolism, for example, fever has been attributed to inflammation and/or tissue necrosis. Exogenous (microbial) pyrogens stimulate both human and animal monocytes/macrophages to produce endogenous pyrogen (EP) in vitro. To determine if plasma and cellular endogeneous mediators (EMs) of inflammation induced EP production, human mononuclear cells (M/L) were incubated for 18 hours with varying amounts of EM and the supernates assayed for EP in rabbits. Neutrophils (PMNs), which do not generate EP and yet are a feature of acute inflammation, were tested. Neither viable, phorbol myristic acetate-stimulated PMNs nor sonicated PMNs, red blood cells, or M/L stimulated human monocytes to produce EP. Human C3b and C5a, which mediate phagocytosis and chemotaxis, respectively, were also inactive. Despite its chemoattractant properties, the synthetic peptide FMLP failed to induce EP release. Since Poly I:Poly C (PIC: a synthetic, double-stranded RNA) is a potent pyrogen in rabbits, we investigated PIC, as well as a native, single-stranded RNA (from E. coli) and DNA (from calf thymus). None was active in vitro, and only PIC caused fever when given to rabbits intravenously. In summary, we have been unable to find an endogenous activator of EP from human monocytes to explain fevers associated with inflammation alone. PMID:3875936

  11. Piezoelectric detection of ion pairs between sulphonate and catecholamines for flow injection analysis of pharmaceutical preparations.

    PubMed

    Mo, Z; Long, X; Zhang, M

    1999-03-01

    Fundamentals of ion-pair flow injection with piezoelectric detection were investigated experimentally and theoretically for the adsorption of dodecyl phenylsulfonate and interfacial ion-pair formation with epinephrine and l-dopa on silver electrode of quartz crystal microbalance. The influences of sulfonate concentration and operating parameters on the frequency response were demonstrated and provided the possibility for the discriminating determination of mixtures. The selected system of ion-pair flow injection with piezoelectric detection was applied to the determination of epinephrine and l-dopa. Calibration curves were linear in ranges 4.00-850 and 3.50-730 mug ml(-1), with detection limits of 1.22 and 1.05 mug ml(-1) and sampling frequencies of 120 samples h(-1), for epinephrine and l-dopa, respectively. The method has been satisfactorily applied to the determination of catecholamines in pharmaceutical preparations.

  12. Coronary CT Angiography-derived Fractional Flow Reserve: Machine Learning Algorithm versus Computational Fluid Dynamics Modeling.

    PubMed

    Tesche, Christian; De Cecco, Carlo N; Baumann, Stefan; Renker, Matthias; McLaurin, Tindal W; Duguay, Taylor M; Bayer, Richard R; Steinberg, Daniel H; Grant, Katharine L; Canstein, Christian; Schwemmer, Chris; Schoebinger, Max; Itu, Lucian M; Rapaka, Saikiran; Sharma, Puneet; Schoepf, U Joseph

    2018-04-10

    Purpose To compare two technical approaches for determination of coronary computed tomography (CT) angiography-derived fractional flow reserve (FFR)-FFR derived from coronary CT angiography based on computational fluid dynamics (hereafter, FFR CFD ) and FFR derived from coronary CT angiography based on machine learning algorithm (hereafter, FFR ML )-against coronary CT angiography and quantitative coronary angiography (QCA). Materials and Methods A total of 85 patients (mean age, 62 years ± 11 [standard deviation]; 62% men) who had undergone coronary CT angiography followed by invasive FFR were included in this single-center retrospective study. FFR values were derived on-site from coronary CT angiography data sets by using both FFR CFD and FFR ML . The performance of both techniques for detecting lesion-specific ischemia was compared against visual stenosis grading at coronary CT angiography, QCA, and invasive FFR as the reference standard. Results On a per-lesion and per-patient level, FFR ML showed a sensitivity of 79% and 90% and a specificity of 94% and 95%, respectively, for detecting lesion-specific ischemia. Meanwhile, FFR CFD resulted in a sensitivity of 79% and 89% and a specificity of 93% and 93%, respectively, on a per-lesion and per-patient basis (P = .86 and P = .92). On a per-lesion level, the area under the receiver operating characteristics curve (AUC) of 0.89 for FFR ML and 0.89 for FFR CFD showed significantly higher discriminatory power for detecting lesion-specific ischemia compared with that of coronary CT angiography (AUC, 0.61) and QCA (AUC, 0.69) (all P < .0001). Also, on a per-patient level, FFR ML (AUC, 0.91) and FFR CFD (AUC, 0.91) performed significantly better than did coronary CT angiography (AUC, 0.65) and QCA (AUC, 0.68) (all P < .0001). Processing time for FFR ML was significantly shorter compared with that of FFR CFD (40.5 minutes ± 6.3 vs 43.4 minutes ± 7.1; P = .042). Conclusion The FFR ML algorithm performs equally in detecting lesion-specific ischemia when compared with the FFR CFD approach. Both methods outperform accuracy of coronary CT angiography and QCA in the detection of flow-limiting stenosis. © RSNA, 2018.

  13. Effect of the positioning of a balloon valve in the aorta on coronary flow during aortic regurgitation.

    PubMed

    Antonatos, P G; Anthopoulos, L P; Kandyla, D D; Karras, A D; Moulopoulos, S D

    1984-07-01

    The coronary artery flow changes relative to the function of a catheter-mounted balloon valve used for relief of aortic regurgitation were studied in 10 mongrel dogs. Acute aortic regurgitation was produced by severing the aortic cusps with a long needle. Coronary flow was recorded from the left anterior descending coronary artery through an electromagnetic flowmeter. When the balloon was functioning within the cavity of the left ventricle there were no significant changes in the coronary flow and aortic pressure, except for a slight decrease in the aortic end-diastolic pressure. When it was functioning in the aortic ring the coronary flow increased 6.52 +/- 1.65 ml/min/100 gm of myocardium (p less than 0.001) and became predominantly diastolic. When it was functioning in the ascending aorta the coronary flow decreased 6.22 +/- 1.16 ml/min/100 gm of myocardium (p less than 0.001) and remained predominantly systolic. Finally, when the balloon was functioning in the thoracic aorta the coronary flow did not change significantly. With the balloon functioning in the aortic ring, ascending aorta, or thoracic aorta, there was a significant increase in the aortic end-diastolic pressure and decrease in the pulse pressure distal to the location of the balloon. It is concluded that the location of the balloon valve inserted for relief of aortic regurgitation influences the effect on coronary arterial flow.

  14. The pumping oxygenator: design criteria and first in vitro results.

    PubMed

    Fiore, G B; Costantino, M L; Fumero, R; Montevecchi, F M

    2000-10-01

    A new project is presented, the pumping oxygenator, functionally integrating pulsatile pumping and blood oxygenation in a single device. Solid, semipermeable silicone membranes allow gas exchange and simultaneously transfer energy from pressurized gas to blood thanks to their distensibility and to inlet and outlet 1-way valves. Two small-sized (1 m2 exchange surface area) prototypes were designed, constructed, hydraulically characterized, and subjected to gas transfer evaluation tests. Blood flow rates (Q(b)) up to 1,250 ml/min were obtained with 30 mm Hg static preload and 130 mm Hg afterload with 0.7 m upstream and 2.1 m downstream 3/8 inch pipes. Physiological oxygen transfer (VO2 = 5 ml/dl, ml of transferred O2/dl of treated blood) was delivered at Q(b) < 900 ml/min, about 4 ml/dl at Q(b) = 1,250 ml/min. VO2 also was significantly increased by increasing percent systolic time. CO2 transfer decreased regularly with increasing Q(b) from VCO2 = 4.8 ml/dl at Q(b) = 400 ml/min to VCO 2 = 2.1 ml/dl at Q(b) = 1,250 ml/min. The results confirm the possibility of integrating oxygenation and pulsatile pumping. The pumping oxygenator represents a promising project deserving further improvements.

  15. Investigating Flow-Structure Interactions in Cerebral Aneurysms

    ScienceCinema

    None

    2018-06-05

    Visualization of blood flow in a cerebral aneurysm. Streamlines (colored by fluid velocity magnitude) reveal the complexity of the flow, isocontours of vorticity show blood vortex structures (colored by pressure), and the flexible arterial wall is colored by the stress magnitude, where regions in red indicate areas of high stress. Credits: Science: Paris Perdikaris, Yue Yu, George Em. Karniadakis and Leopold Grinberg Visualization: Joseph A. Insley and Michael E. Papka

  16. The Effect of Isovolemic Hemodilution with Oxycyte®, a Perfluorocarbon Emulsion, on Cerebral Blood Flow in Rats

    PubMed Central

    Yang, Zhong-jin; Price, Chrystal D.; Bosco, Gerardo; Tucci, Micheal; El-Badri, Nagwa S.; Mangar, Devanand; Camporesi, Enrico M.

    2008-01-01

    Background Cerebral blood flow (CBF) is auto-regulated to meet the brain's metabolic requirements. Oxycyte® is a perfluorocarbon emulsion that acts as a highly effective oxygen carrier compared to blood. The aim of this study is to determine the effects of Oxycyte® on regional CBF (rCBF), by evaluating the effects of stepwise isovolemic hemodilution with Oxycyte® on CBF. Methodology Male rats were intubated and ventilated with 100% O2 under isoflurane anesthesia. The regional (striatum) CBF (rCBF) was measured with a laser doppler flowmeter (LDF). Stepwise isovolemic hemodilution was performed by withdrawing 4ml of blood and substituting the same volume of 5% albumin or 2 ml Oxycyte® plus 2 ml albumin at 20-minute intervals until the hematocrit (Hct) values reached 5%. Principal Findings In the albumin-treated group, rCBF progressively increased to approximately twice its baseline level (208±30%) when Hct levels were less than 10%. In the Oxycyte®-treated group on the other hand, rCBF increased by significantly smaller increments, and this group's mean rCBF was only slightly higher than baseline (118±18%) when Hct levels were less than 10%. Similarly, in the albumin-treated group, rCBF started to increase when hemodilution with albumin caused the CaO2 to decrease below 17.5 ml/dl. Thereafter, the increase in rCBF was accompanied by a nearly proportional decrease in the CaO2 level. In the Oxycyte®-treated group, the increase in rCBF was significantly smaller than in the albumin-treated group when the CaO2 level dropped below 10 ml/dl (142±20% vs. 186±26%), and rCBF returned to almost baseline levels (106±15) when the CaO2 level was below 7 ml/dl. Conclusions/Significance Hemodilution with Oxycyte® was accompanied with higher CaO2 and PO2 than control group treated with albumin alone. This effect may be partially responsible for maintaining relatively constant CBF and not allowing the elevated blood flow that was observed with albumin. PMID:18431491

  17. Cytometry metadata in XML

    NASA Astrophysics Data System (ADS)

    Leif, Robert C.; Leif, Stephanie H.

    2016-04-01

    Introduction: The International Society for Advancement of Cytometry (ISAC) has created a standard for the Minimum Information about a Flow Cytometry Experiment (MIFlowCyt 1.0). CytometryML will serve as a common metadata standard for flow and image cytometry (digital microscopy). Methods: The MIFlowCyt data-types were created, as is the rest of CytometryML, in the XML Schema Definition Language (XSD1.1). The datatypes are primarily based on the Flow Cytometry and the Digital Imaging and Communication (DICOM) standards. A small section of the code was formatted with standard HTML formatting elements (p, h1, h2, etc.). Results:1) The part of MIFlowCyt that describes the Experimental Overview including the specimen and substantial parts of several other major elements has been implemented as CytometryML XML schemas (www.cytometryml.org). 2) The feasibility of using MIFlowCyt to provide the combination of an overview, table of contents, and/or an index of a scientific paper or a report has been demonstrated. Previously, a sample electronic publication, EPUB, was created that could contain both MIFlowCyt metadata as well as the binary data. Conclusions: The use of CytometryML technology together with XHTML5 and CSS permits the metadata to be directly formatted and together with the binary data to be stored in an EPUB container. This will facilitate: formatting, data- mining, presentation, data verification, and inclusion in structured research, clinical, and regulatory documents, as well as demonstrate a publication's adherence to the MIFlowCyt standard, promote interoperability and should also result in the textual and numeric data being published using web technology without any change in composition.

  18. Lung cancer perfusion: can we measure pulmonary and bronchial circulation simultaneously?

    PubMed

    Yuan, Xiaodong; Zhang, Jing; Ao, Guokun; Quan, Changbin; Tian, Yuan; Li, Hong

    2012-08-01

    To describe a new CT perfusion technique for assessing the dual blood supply in lung cancer and present the initial results. This study was approved by the institutional review board. A CT protocol was developed, and a dual-input CT perfusion (DI-CTP) analysis model was applied and evaluated regarding the blood flow fractions in lung tumours. The pulmonary trunk and the descending aorta were selected as the input arteries for the pulmonary circulation and the bronchial circulation respectively. Pulmonary flow (PF), bronchial flow (BF), and a perfusion index (PI, = PF/ (PF + BF)) were calculated using the maximum slope method. After written informed consent was obtained, 13 consecutive subjects with primary lung cancer underwent DI-CTP. Perfusion results are as follows: PF, 13.45 ± 10.97 ml/min/100 ml; BF, 48.67 ± 28.87 ml/min/100 ml; PI, 21 % ± 11 %. BF is significantly larger than PF, P < 0.001. There is a negative correlation between the tumour volume and perfusion index (r = 0.671, P = 0.012). The dual-input CT perfusion analysis method can be applied successfully to lung tumours. Initial results demonstrate a dual blood supply in primary lung cancer, in which the systemic circulation is dominant, and that the proportion of the two circulation systems is moderately dependent on tumour size. A new CT perfusion technique can assess lung cancer's dual blood supply. A dual blood supply was confirmed with dominant bronchial circulation in lung cancer. The proportion of the two circulations is moderately dependent on tumour size. This new technique may benefit the management of lung cancer.

  19. Development and Optimization of HPLC Analysis of Metronidazole, Diloxanide, Spiramycin and Cliquinol in Pharmaceutical Dosage Forms Using Experimental Design.

    PubMed

    Elkhoudary, Mahmoud M; Abdel Salam, Randa A; Hadad, Ghada M

    2016-11-01

    A new simple, sensitive, rapid and accurate gradient reversed-phase high-performance liquid chromatography with photodiode array detector (RP-HPLC-DAD) was developed and validated for simultaneous analysis of Metronidazole (MNZ), Spiramycin (SPY), Diloxanidefuroate (DIX) and Cliquinol (CLQ) using statistical experimental design. Initially, a resolution V fractional factorial design was used in order to screen five independent factors: the column temperature (°C), pH, phosphate buffer concentration (mM), flow rate (ml/min) and the initial fraction of mobile phase B (%). pH, flow rate and initial fraction of mobile phase B were identified as significant, using analysis of variance. The optimum conditions of separation determined with the aid of central composite design were: (1) initial mobile phase concentration: phosphate buffer/methanol (50/50, v/v), (2) phosphate buffer concentration (50 mM), (3) pH (4.72), (4) column temperature 30°C and (5) mobile phase flow rate (0.8 ml min -1 ). Excellent linearity was observed for all of the standard calibration curves, and the correlation coefficients were above 0.9999. Limits of detection for all of the analyzed compounds ranged between 0.02 and 0.11 μg ml -1 ; limits of quantitation ranged between 0.06 and 0.33 μg ml -1 The proposed method showed good prediction ability. The optimized method was validated according to ICH guidelines. Three commercially available tablets were analyzed showing good % recovery and %RSD. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Biohydrogen production in a continuous stirred tank bioreactor from synthesis gas by anaerobic photosynthetic bacterium: Rhodopirillum rubrum.

    PubMed

    Younesi, Habibollah; Najafpour, Ghasem; Ku Ismail, Ku Syahidah; Mohamed, Abdul Rahman; Kamaruddin, Azlina Harun

    2008-05-01

    Hydrogen may be considered a potential fuel for the future since it is carbon-free and oxidized to water as a combustion product. Bioconversion of synthesis gas (syngas) to hydrogen was demonstrated in continuous stirred tank bioreactor (CSTBR) utilizing acetate as a carbon source. An anaerobic photosynthetic bacterium, Rhodospirillum rubrum catalyzed water-gas shift reaction which was applied for the bioconversion of syngas to hydrogen. The continuous fermentation of syngas in the bioreactor was continuously operated at various gas flow rates and agitation speeds, for the period of two months. The gas flow rates were varied from 5 to 14 ml/min. The agitation speeds were increasingly altered in the range of 150-500 rpm. The pH and temperature of the bioreactor was set at 6.5 and 30 degrees C. The liquid flow rate was kept constant at 0.65 ml/min for the duration of 60 days. The inlet acetate concentration was fed at 4 g/l into the bioreactor. The hydrogen production rate and yield were 16+/-1.1 mmol g(-1)cell h(-1) and 87+/-2.4% at fixed agitation speed of 500 rpm and syngas flow rate of 14 ml/min, respectively. The mass transfer coefficient (KLa) at this condition was approximately 72.8h(-1). This new approach, using a biocatalyst was considered as an alternative method of conventional Fischer-Tropsch synthetic reactions, which were able to convert syngas into hydrogen.

  1. Photocatalytic degradation of humic acid in saline waters. Part 1. Artificial seawater: influence of TiO2, temperature, pH, and air-flow.

    PubMed

    Al-Rasheed, Radwan; Cardin, David J

    2003-06-01

    We report the first systematic study on the photocatalytic oxidation of humic acid (HA) in artificial seawater (ASW). TiO(2) (Degussa P25) dispersions were used as the catalyst with irradiation from a medium-pressure mercury lamp. The optimum quantity of catalyst was found to be between 2 and 2.5 gl(-1); while the decomposition was fastest at low pH values (pH 4.5 in the range examined), and the optimum air-flow, using an immersion well reactor with a capacity of 400 ml, was 850 ml min(-1). Reactivity increased with air-flow up to this figure, above which foaming prevented operation of the reactor. Using pure oxygen, an optimal flow rate was observed at 300 ml min(-1), above which reactivity remains essentially constant. Following treatment for 1 h, low-salinity water (2700 mg l(-1)) was completely mineralised, whereas ASW (46000 mg l(-1)) had traces of HA remaining. These effects are interpreted and kinetic data presented. To avoid problems of precipitation due to change of ionic strength humic substances were prepared directly in ASW, and the effects of ASW on catalyst suspension and precipitation have been taken into account. The Langmuir-Hinshelwood kinetic model has been shown to be followed only approximately for the catalytic oxidation of HA in ASW. The activation energy for the reaction derived from an Arrhenius treatment was 17 (+/-0.6) kJ mol(-1).

  2. Muscle contraction duration and fibre recruitment influence blood flow and oxygen consumption independent of contractile work during steady-state exercise in humans.

    PubMed

    Richards, Jennifer C; Crecelius, Anne R; Kirby, Brett S; Larson, Dennis G; Dinenno, Frank A

    2012-06-01

    We tested the hypothesis that, among conditions of matched contractile work, shorter contraction durations and greater muscle fibre recruitment result in augmented skeletal muscle blood flow and oxygen consumption ( ) during steady-state exercise in humans. To do so, we measured forearm blood flow (FBF; Doppler ultrasound) during 4 min of rhythmic hand-grip exercise in 24 healthy young adults and calculated forearm oxygen consumption ( ) via blood samples obtained from a catheter placed in retrograde fashion into a deep vein draining the forearm muscle. In protocol 1 (n = 11), subjects performed rhythmic isometric hand-grip exercise at mild and moderate intensities during conditions in which time-tension index (isometric analogue of work) was held constant but contraction duration was manipulated. In this protocol, shorter contraction durations led to greater FBF (184 ± 25 versus 164 ± 25 ml min(-1)) and (23 ± 3 versus 17 ± 2 ml min(-1); both P < 0.05) among mild workloads, whereas this was not the case for moderate-intensity exercise. In protocol 2 (n = 13), subjects performed rhythmic dynamic hand-grip exercise at mild and moderate intensities in conditions of matched total work, but muscle fibre recruitment was manipulated. In this protocol, greater muscle fibre recruitment led to significantly greater FBF (152 ± 15 versus 127 ± 13 ml min(-1)) and (20 ± 2 versus 17 ± 2 ml min(-1); both P < 0.05) at mild workloads, and there was a trend for similar responses at the moderate intensity but this was not statistically significant. In both protocols, the ratio of the change in FBF to change in was similar across all exercise intensities and manipulations, and the strongest correlation among all variables was between and blood flow. Our collective data indicate that, among matched workloads, shorter contraction duration and greater muscle fibre recruitment augment FBF and during mild-intensity forearm exercise, and that muscle blood flow is more closely related to metabolic cost ( ) rather than contractile work per se during steady-state exercise in humans.

  3. Ensemble engineering and statistical modeling for parameter calibration towards optimal design of microbial fuel cells

    NASA Astrophysics Data System (ADS)

    Sun, Hongyue; Luo, Shuai; Jin, Ran; He, Zhen

    2017-07-01

    Mathematical modeling is an important tool to investigate the performance of microbial fuel cell (MFC) towards its optimized design. To overcome the shortcoming of traditional MFC models, an ensemble model is developed through integrating both engineering model and statistical analytics for the extrapolation scenarios in this study. Such an ensemble model can reduce laboring effort in parameter calibration and require fewer measurement data to achieve comparable accuracy to traditional statistical model under both the normal and extreme operation regions. Based on different weight between current generation and organic removal efficiency, the ensemble model can give recommended input factor settings to achieve the best current generation and organic removal efficiency. The model predicts a set of optimal design factors for the present tubular MFCs including the anode flow rate of 3.47 mL min-1, organic concentration of 0.71 g L-1, and catholyte pumping flow rate of 14.74 mL min-1 to achieve the peak current at 39.2 mA. To maintain 100% organic removal efficiency, the anode flow rate and organic concentration should be controlled lower than 1.04 mL min-1 and 0.22 g L-1, respectively. The developed ensemble model can be potentially modified to model other types of MFCs or bioelectrochemical systems.

  4. Vagal nerve stimulation modulates the dendritic cell profile in posthemorrhagic shock mesenteric lymph.

    PubMed

    Morishita, Koji; Costantini, Todd W; Eliceiri, Brian; Bansal, Vishal; Coimbra, Raul

    2014-03-01

    Previous studies have established that posthemorrhagic shock mesenteric lymph (PHSML) contains proinflammatory mediators, while the cellular basis of PHSML is less well characterized in acute models of injury. CD103 dendritic cells (DCs) have been identified in the mesenteric lymph (ML) in models of chronic intestinal inflammation, suggesting an important role in the gut response to injury. We have previously demonstrated the ability of vagal nerve stimulation (VNS) to prevent gut barrier failure after trauma/hemorrhagic shock (T/HS); however, the ability of VNS to alter ML DCs is unknown. We hypothesized that the CD103 MHC-II DC population would change in PHSML and that VNS would prevent injury-induced changes in this population in PHSML. Male Sprague-Dawley rats were randomly assigned to trauma/sham shock or T/HS. T/HS was induced by midline laparotomy and 60 minutes of HS (blood pressure, 35 mm Hg), followed by fluid resuscitation. A separate cohort of animals underwent cervical VNS after the HS phase. Gut tissue was harvested at 2 hours after injury for histologic analysis. ML was collected during the pre-HS, HS, and post-HS phase. For flow cytometric analysis, ML cells were subjected to staining with CD103 and MHC-II antibodies, and this cell population was compared in the pre-HS and post-HS phase from the same animal. The CD4Foxp3 cell (T reg) population in the ML node (MLN) was also tested to determine effects of CD103 DC modulation in the ML. VNS reduced histologic gut injury and ML flow seen after injury. The CD103 MHC-II DC population in the PHSML was significantly decreased compared with pre-HS and was associated with decreased T reg expression in the MLN. VNS prevented the injury-induced decrease in the CD103 MHC-II+ DC population in the ML and restored the T reg population in the MLN. These findings suggest that VNS mediates the inflammatory responses in ML DCs and MLN T reg cells by affecting the set point of T/HS responsiveness.

  5. Daily and annually variation of unstimulated whole saliva flow rate and pH and their relation with body profile in healthy young adults.

    PubMed

    Foglio-Bonda, P L; Migliario, M; Rocchetti, V; Pattarino, F; Foglio-Bonda, A

    2013-09-01

    To analyse pH and flow rate (FR) of unstimulated whole saliva (UWS), detecting their possible correlations both among themselves and with body profile; in addition to identify daily, annually and gender differences. Eighty-one (47 ♀; 34 ♂) healthy young adults (mean age 22.7±4.09 years old) were enrolled. Saliva was sampled using spitting method. The data were statistically analysed using Pearson's coefficient, ANOVA or Kruskal-Wallis test, Student's t test or the Wilcoxon-Mann-Whitney test. The mean UWS/FR was 0.643 ml/min (range 0.164-1.656 ml/min; percentile 25 = 0.400 ml/min; percentile 50 = 0.643 ml/min, percentile 75 = 0.832 ml/min; median = 0.590 ml/min) and no significant differences were found in gender. The mean UWS/pH was 6.95 (range 6.06-7.91, S.D. 0.28, RSD % 4.08): pH was higher in males (7.02) than females (6.92; p = 0.009). The UWS/FR increased almost steadily during the day: from 0.593 ml/min at 9:00 to 0.669 ml/min at 17:00 (p = 0.04), the greatest increase was found between 9:00 and 11:00. Through the seasons the UWS/FR decreased from summer to spring with a difference of 0.048 ml/min (p < 0.05). The UWS/pH showed a slight increase between 9:00 and 17:00 (p < 0.05). There were little differences in UWS/pH among the seasons (max. 0.09; p < 0.05). Only a significant correlation between UWS/FR and pH was found (R = 0.20; p = 0.008). We did not find correlations between body profile vs UWS/FR or pH. UWS/FR varies more widely than UWS/pH: maintaining a proper acid/base balance is an essential factor for the homeostasis of the oral cavity and probably this would explain the reason for the lack of the variables evaluated influencing UWS/pH.

  6. Multi-parameter comparison of injection laryngoplasty, medialization laryngoplasty, and arytenoid adduction in an excised larynx model

    PubMed Central

    Hoffman, Matthew R.; Witt, Rachel E.; Chapin, William J.; McCulloch, Timothy M.; Jiang, Jack J.

    2010-01-01

    Objective Evaluate the effect of injection laryngoplasty (IL), medialization laryngoplasty (ML), and ML combined with arytenoid adduction (ML-AA) on acoustic, aerodynamic, and mucosal wave measurements in an excised larynx setup. Methods Measurements were recorded for eight excised canine larynges with simulated unilateral vocal fold paralysis (UVFP) before and after vocal fold injection with Cymetra. A second set of eight larynges was used to evaluate medialization laryngoplasty using a Silastic implant without and with arytenoid adduction. Results IL and ML led to comparable decreases in phonation threshold flow (PTF), phonation threshold pressure (PTP), and phonation threshold power (PTW). ML-AA led to significant decreases in PTF (p=0.008), PTP (p=0.008), and PTW (p=0.008). IL and ML led to approximately equal decreases in percent jitter and percent shimmer. ML-AA caused the greatest increase in signal to noise ratio (SNR). ML-AA discernibly decreased frequency (p=0.059); a clear trend was not observed for IL or ML. IL significantly reduced mucosal wave amplitude (p=0.002), while both ML and ML-AA increased it. All procedures significantly decreased glottal gap, with the most dramatic effects observed after ML-AA (p=0.004). Conclusions ML-AA led to the greatest improvements in phonatory parameters. IL was comparable to ML aerodynamically and acoustically, but caused detrimental changes to the mucosal wave. Incremental improvements in parameters recorded from the same larynx were observed after ML and ML-AA. To ensure optimal acoustic outcome, the arytenoid must be correctly rotated. This study provides objective support for the combined ML-AA procedure in tolerant patients. Evidence based medicine level Not applicable – animal study. PMID:20213797

  7. Variability of uterine blood flow in lactating cows during the second half of gestation.

    PubMed

    Herzog, Kathrin; Koerte, Juliane; Flachowsky, Gerhard; Bollwein, Heinrich

    2011-06-01

    The main goal of the present study was to measure uterine blood flow volume (BFV) in the second half of gestation in lactating German Holstein cows. Furthermore, it was investigated, if there are individual variations in uterine blood flow and correlations between uterine blood flow and maternal weight and the birth weight of the calf. Forty-four cows were examined via color Doppler sonography in gestation weeks (GW) 21, 25, 29, 33, 37 and 39. The cows were allocated in groups based on the following variables: body weight (light ≤ 575 kg, heavy > 575 kg) and birth weight of the calf (light ≤ 42 kg, heavy > 42 kg). The BFV was measured via transrectal Doppler sonography of both uterine arteries. There was a linear increase in uterine BFV throughout the study period from 3053 ± 1143 ml/min to 16912 ± 5793 ml/min. Variation coefficients for inter-individual variations ranged from 34 to 37%. There was a moderate correlation between uterine BFV and birth weight of the calf in weeks 21 to 37 (0.30 ≤ r < 0.49; P < 0.05) and a good correlation in week 39 (r = 0.60; P < 0.0001). Uterine BFV in week 21 was significantly (P < 0.01) higher in heavy cows (3394 ± 1119 ml/min) than in light cows (2658 ± 1064 ml/min). Compared with light cows, the increase in uterine BFV was 32% higher in heavy cows during the study period. In week 21, there was no difference (P > 0.05) in uterine BFV between cows carrying a heavy calf (3351 ± 1130 ml/min) and those carrying a light calf (2796 ± 1115 ml/min). Thereafter, the increase of BFV was 43% higher in cows with a heavy calf than in those carrying a light calf. Cows with different body weights, but same birth weight of calf showed no differences (P > 0.05) in the increase of BFV, while in cows with the same body weight the rise in BFV was higher (P < 0.05) in those cows producing a heavy calf compared to cows carrying calves with light birth weights. In conclusion, there was a linear increase in uterine BFV in lactating Holstein cows during the second half of pregnancy with marked individual variations. Differences in the rise of BFV were more caused by the fetus than by body weight of cows. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Progress on an implementation of MIFlowCyt in XML

    NASA Astrophysics Data System (ADS)

    Leif, Robert C.; Leif, Stephanie H.

    2015-03-01

    Introduction: The International Society for Advancement of Cytometry (ISAC) Data Standards Task Force (DSTF) has created a standard for the Minimum Information about a Flow Cytometry Experiment (MIFlowCyt 1.0). The CytometryML schemas, are based in part upon the Flow Cytometry Standard and Digital Imaging and Communication (DICOM) standards. CytometryML has and will be extended and adapted to include MIFlowCyt, as well as to serve as a common standard for flow and image cytometry (digital microscopy). Methods: The MIFlowCyt data-types were created, as is the rest of CytometryML, in the XML Schema Definition Language (XSD1.1). Individual major elements of the MIFlowCyt schema were translated into XML and filled with reasonable data. A small section of the code was formatted with HTML formatting elements. Results: The differences in the amount of detail to be recorded for 1) users of standard techniques including data analysts and 2) others, such as method and device creators, laboratory and other managers, engineers, and regulatory specialists required that separate data-types be created to describe the instrument configuration and components. A very substantial part of the MIFlowCyt element that describes the Experimental Overview part of the MIFlowCyt and substantial parts of several other major elements have been developed. Conclusions: The future use of structured XML tags and web technology should facilitate searching of experimental information, its presentation, and inclusion in structured research, clinical, and regulatory documents, as well as demonstrate in publications adherence to the MIFlowCyt standard. The use of CytometryML together with XML technology should also result in the textual and numeric data being published using web technology without any change in composition. Preliminary testing indicates that CytometryML XML pages can be directly formatted with the combination of HTML and CSS.

  9. Activities of Fluconazole, Caspofungin, Anidulafungin, and Amphotericin B on Planktonic and Biofilm Candida Species Determined by Microcalorimetry

    PubMed Central

    Maiolo, Elena Maryka; Furustrand Tafin, Ulrika; Borens, Olivier

    2014-01-01

    We investigated the activities of fluconazole, caspofungin, anidulafungin, and amphotericin B against Candida species in planktonic form and biofilms using a highly sensitive assay measuring growth-related heat production (microcalorimetry). C. albicans, C. glabrata, C. krusei, and C. parapsilosis were tested, and MICs were determined by the broth microdilution method. The antifungal activities were determined by isothermal microcalorimetry at 37°C in RPMI 1640. For planktonic Candida, heat flow was measured in the presence of antifungal dilutions for 24 h. Candida biofilm was formed on porous glass beads for 24 h and exposed to serial dilutions of antifungals for 24 h, and heat flow was measured for 48 h. The minimum heat inhibitory concentration (MHIC) was defined as the lowest antifungal concentration reducing the heat flow peak by ≥50% (≥90% for amphotericin B) at 24 h for planktonic Candida and at 48 h for Candida biofilms (measured also at 24 h). Fluconazole (planktonic MHICs, 0.25 to >512 μg/ml) and amphotericin B (planktonic MHICs, 0.25 to 1 μg/ml) showed higher MHICs than anidulafungin (planktonic MHICs, 0.015 to 0.5 μg/ml) and caspofungin (planktonic MHICs, 0.125 to 0.5 μg/ml). Against Candida species in biofilms, fluconazole's activity was reduced by >1,000-fold compared to its activity against the planktonic counterparts, whereas echinocandins and amphotericin B mainly preserved their activities. Fluconazole induced growth of planktonic C. krusei at sub-MICs. At high concentrations of caspofungin (>4 μg/ml), paradoxical growth of planktonic C. albicans and C. glabrata was observed. Microcalorimetry enabled real-time evaluation of antifungal activities against planktonic and biofilm Candida organisms. It can be used in the future to evaluate new antifungals and antifungal combinations and to study resistant strains. PMID:24566186

  10. Liquid egg white pasteurization using a centrifugal UV irradiator.

    PubMed

    Geveke, David J; Torres, Daniel

    2013-03-01

    Studies are limited on UV nonthermal pasteurization of liquid egg white (LEW). The objective of this study was to inactivate Escherichia coli using a UV irradiator that centrifugally formed a thin film of LEW on the inside of a rotating cylinder. The LEW was inoculated with E. coli K12 to approximately 8 log cfu/ml and was processed at the following conditions: UV intensity 1.5 to 9.0 mW/cm²; cylinder rotational speed 450 to 750 RPM, cylinder inclination angle 15° to 45°, and flow rate 300 to 900 ml/min, and treatment time 1.1 to 3.2s. Appropriate dilutions of the samples were pourplated with tryptic soy agar (TSA). Sublethal injury was determined using TSA+4% NaCl. The regrowth of surviving E. coli during refrigerated storage for 28 days was investigated. The electrical energy of the UV process was also determined. The results demonstrated that UV processing of LEW at a dose of 29 mJ/cm² at 10°C reduced E. coli by 5 log cfu/ml. Inactivation significantly increased with increasing UV dose and decreasing flow rate. The results at cylinder inclination angles of 30° and 45° were similar and were significantly better than those at 15°. The cylinder rotational speed had no significant effect on inactivation. The occurrence of sublethal injury was detected. Storage of UV processed LEW at 4° and 10°C for 21 days further reduced the population of E. coli to approximately 1 log cfu/ml where it remained for an additional 7 days. The UV energy applied to the LEW to obtain a 5 log reduction of E. coli was 3.9 J/ml. These results suggest that LEW may be efficiently pasteurized, albeit at low flow rates, using a nonthermal UV device that centrifugally forms a thin film. Published by Elsevier B.V.

  11. Influence of blood flow on adsorption of beta2-microglobulin onto AN69 dialyzer membrane.

    PubMed

    Kandus, A; Malovrh, M; Bren, A F

    1997-08-01

    Adsorption onto the dialyzer membrane is a contributing factor to the elimination of beta2-microglobulin (beta2M) from the sera of uremic patients. The purpose of this prospective study was to ascertain the influence of the blood flow rate on adsorption of beta2M onto the polyacrylonitrile (AN69) hollow-fiber dialyzer membrane in 8 patients during regular hemodialysis (HD). Blood first passed through a low-flux polysulfone dialyzer and then through an AN69 dialyzer, which was not in contact with the dialysis fluid. During the investigation period (first hour of the HD session), the blood flow rate was 100 ml/ min (first part of the study), 200 ml/min (second part of the study), and 300 ml/min (third part of the study). Ultrafiltration was not performed during the investigation period. At the start of the HD sessions, the serum concentration of beta2M in the afferent blood line did not differ significantly among the 3 parts of the study. Serum beta2M was measured in samples taken from the afferent and efferent blood lines of the AN69 dialyzer at 5, 10, 15, 30, 45, and 60 min. The serum beta2M concentration decreased significantly in blood that had passed through the AN69 dialyzer. This decrease, indicating membrane adsorption, was maximal during the first part and minimal during the third part of study. The decrease in the contact time between the blood and the AN69 could be the underlying cause. The calculated quantities of beta2M adsorbed onto the AN69 membrane (44.2 +/- 10.2, 43.2 +/- 12.1, and 42.6 +/- 17.3 mg) did not differ significantly among the 3 parts of the study. These results suggest that an increase in blood flow rate from 100 to 300 ml/min did not significantly affect the quantity of beta2M adsorbed onto the AN69 membrane.

  12. Flow cytometric characterization of the response of Fanconi's anemia cells to mitomycin C treatment.

    PubMed

    Kaiser, T N; Lojewski, A; Dougherty, C; Juergens, L; Sahar, E; Latt, S A

    1982-03-01

    DNA flow histogram analysis, using 33342 Hoechst as a stain, has been used to detect the effect of the potentially bifunctional alkylating agent, mitomycin C (MMC) on dermal fibroblasts from patients with Fanconi's anemia (FA), a hereditary human disease characterized by pancytopenia, hypersensitivity to DNA-crosslinking agents, congenital abnormalities and a predisposition for neoplasia. At 24 or 48 hr after a 2-hr exposure to 0.05 or 0.10 micrograms/ml MMC, (3)HdT incorporation was reduced to a greater extent in FA cells than in normal cells. Cells sorted from the last half of S phase showed a slightly greater inhibition of (3)HdT incorporation than did those sorted from the first half of S. Fanconi's anemia cells exhibited a marked accumulation in the G(2) + M peak of flow histograms following exposure to MMC. Twenty-four hr after treatment with .0.5 micrograms/ml MMC, the G(2) + M fraction of FA cells (eight lines) increased to more than 0.5 from a control value of approximately 0.02. Both normals (six lines) and heterozygotes (eight lines) showed, on the average, much less of a G(2) + M increment than did FA cells, even after exposure to 0.1 micrograms/ml MMC. Examination of cells sorted from the G(2) + M peak revealed that MMC-treated FA cells were blocked prior to mitosis. To determine whether the response of FA cells was specific for bifunctional alkylating agent, cells were also treated with ethylmethanesulfonate, a monofunctional agent. Twenty-four hours after exposure to 0.25 or 0.5 mg/ml ethylmethanesulfonate, FA and normal cells showed similar, small increases in the G(2) + M peak. The results suggest the utility of flow cytometry in the diagnostic evaluation of fibroblasts from patients suspected of having Fanconi's anemia.

  13. [Laser-induced thermotherapy (LITT) of lung metastases: description of a miniaturized applicator, optimization, and initial treatment of patients].

    PubMed

    Hosten, N; Stier, A; Weigel, C; Kirsch, M; Puls, R; Nerger, U; Jahn, D; Stroszczynski, C; Heidecke, C-D; Speck, U

    2003-03-01

    A thin-caliber applicator system was developed for introducing a laser fiber under CT guidance into lung metastases with only minimal complications. A space-saving 5.5 French Teflon cannula with a titanium trocar and connectors for a laser light guide (2 or 3 cm Dornier Diffusor-Tip H-6111-T2 or H-6111-T3 coupled to a Dornier Medilas Fibertom 5100 laser, wavelength of 1064 nm) and a perfusion line for physiologic saline solution were developed. After puncture the laser Diffusor-Tip remains in the cannula and is cooled during its tissue passage by slowly flowing saline solution. The miniaturized applicator system (Monocath) was calibrated in nonperfused bovine liver for maximum energy supply and necessary flow of the cooling saline solution in reference to a commercially available 9 French laser catheter with an 11.5 French inducer sheath (Power-Applicator). The new applicator system was used for treating lung metastases in 10 patients over a period of 21 months. The size of heat coagulation in bovine liver was 24 +/- 2 ml using the miniaturized system with application of 15 W for 20 min and a saline flow of 0.75 ml/min, in comparison to a size of 29 +/- 7 ml for the commercial applicator (30 W, 20 min, 60 ml/min). All metastases could be safely approached with the miniaturized applicator, except for two metastatic lesions at the lung base in two patients. A minor pneumothorax developed in three patients and intrapulmonary bleeding in two. Contrast-enhanced CT demonstrated necrosis of the treated metastatic areas in 6 patients. Follow-up of three patients after 5, 6, and 8 months showed complete tumor regression with minimal scarring in one patient. The miniaturized applicator system enables the introduction of a laser fiber into pulmonary metastases with only minor complications. Complete ablation seems to be achievable in suitable patients with the applied laser energy and a slow cooling fluid flow rate.

  14. Quantification of circulating mature endothelial cells using a whole blood four-color flow cytometric assay.

    PubMed

    Jacques, Nathalie; Vimond, Nadege; Conforti, Rosa; Griscelli, Franck; Lecluse, Yann; Laplanche, Agnes; Malka, David; Vielh, Philippe; Farace, Françoise

    2008-09-15

    Circulating endothelial cells (CEC) are currently proposed as a potential biomarker for measuring the impact of anti-angiogenic treatments in cancer. However, the lack of consensus on the appropriate method of CEC measurement has led to conflicting data in cancer patients. A validated assay adapted for evaluating the clinical utility of CEC in large cohorts of patients undergoing anti-angiogenic treatments is needed. We developed a four-color flow cytometric assay to measure CEC as CD31(+), CD146(+), CD45(-), 7-amino-actinomycin-D (7AAD)(-) events in whole blood. The distinctive features of the assay are: (1) staining of 1 ml whole blood, (2) use of a whole blood IgPE control to measure accurately background noise, (3) accumulation of a large number of events (almost 5 10(6)) to ensure statistical analysis, and (4) use of 10 microm fluorescent microbeads to evaluate the event size. Assay reproducibility was determined in duplicate aliquots of samples drawn from 20 metastatic cancer patients. Assay linearity was tested by spiking whole blood with low numbers of HUVEC. Five-color flow cytometric experiments with CD144 were performed to confirm the endothelial origin of the cells. CEC were measured in 20 healthy individuals and 125 patients with metastatic cancer. Reproducibility was good between duplicate aliquots (r(2)=0.948, mean difference between duplicates of 0.86 CEC/ml). Detected HUVEC correlated with spiked HUVEC (r(2)=0.916, mean recovery of 100.3%). Co-staining of CD31, CD146 and CD144 confirmed the endothelial nature of cells identified as CEC. Median CEC levels were 6.5/ml (range, 0-15) in healthy individuals and 15.0/ml (range, 0-179) in patients with metastatic carcinoma (p<0.001). The assay proposed here allows reproducible and sensitive measurement of CEC by flow cytometry and could help evaluate CEC as biomarkers of anti-angiogenic therapies in large cohorts of patients.

  15. Very Preterm Infants Failing CPAP Show Signs of Fatigue Immediately after Birth

    PubMed Central

    Siew, Melissa L.; van Vonderen, Jeroen J.; Hooper, Stuart B.; te Pas, Arjan B.

    2015-01-01

    Objective To investigate the differences in breathing pattern and effort in infants at birth who failed or succeeded on continuous positive airway pressure (CPAP) during the first 48 hours after birth. Methods Respiratory function recordings of 32 preterm infants were reviewed of which 15 infants with a gestational age of 28.6 (0.7) weeks failed CPAP and 17 infants with a GA of 30.1 (0.4) weeks did not fail CPAP. Frequency, duration and tidal volumes (VT) of expiratory holds (EHs), peak inspiratory flows, CPAP-level and FiO2-levels were analysed. Results EH incidence increased <6 minutes after birth and remained stable thereafter. EH peak inspiratory flows and VT were similar between CPAP-fail and CPAP-success infants. At 9-12 minutes, CPAP-fail infants more frequently used smaller VTs, 0-9 ml/kg and required higher peak inspiratory flows. However, CPAP-success infants often used large VTs (>9 ml/kg) with higher peak inspiratory flows than CPAP-fail infants (71.8 ± 15.8 vs. 15.5 ± 5.2 ml/kg.s, p <0.05). CPAP-fail infants required higher FiO2 (0.31 ± 0.03 vs. 0.21 ± 0.01), higher CPAP pressures (6.62 ± 0.3 vs. 5.67 ± 0.26 cmH2O) and more positive pressure-delivered breaths (45 ± 12 vs. 19 ± 9%) (p <0.05) Conclusion At 9-12 minutes after birth, CPAP-fail infants more commonly used lower VTs and required higher peak inspiratory flow rates while receiving greater respiratory support. VT was less variable and larger VT was infrequently used reflecting early signs of fatigue. PMID:26052947

  16. Blood flow variation in human muscle during electrically stimulated exercise bouts.

    PubMed

    Vanderthommen, Marc; Depresseux, Jean-Claude; Dauchat, Luc; Degueldre, Christian; Croisier, Jean-Louis; Crielaard, Jean-Michel

    2002-07-01

    To evaluate, with a high spatial resolution, the blood flow variations in human skeletal muscle during neuromuscular electric stimulation (NMES) and hence to gain better understanding of the mechanisms of muscle spatial recruitment during NMES. One thigh was submitted to 3 stimulation bouts of different durations (S1=4min, S2=8min, S3=12min) with a workload corresponding to 10% of quadriceps maximal isometric voluntary torque. A cyclotron research center at a Belgian university. Ten healthy male volunteers. Not applicable. Participants were studied with positron emission tomography and H(2)(15)O. Tissue blood flow was evaluated during the last 4 minutes of each stimulation bout in multiple regions of interest (ROIs) selected in the transverse section of the stimulated thigh. Mean tissue blood flow was significantly lower during S1 (5.9+/-1.3mL. min(-1). 100g(-1)) than during S2 (10.6+/-3.4mL. min(-1). 100g(-1)) and S3 (11.6+/-3.7mL. min(-1). 100g(-1)) (P<.05). For each ROI, an arbitrary tissue blood flow activation level of 5mLmin(-1)100g(-1) was fixed. The mean percentage of activated ROIs reached 42.4%, 62.7%, and 63.6% during S1, S2, and S3, respectively. Between S1 and S3, the newly recruited ROIs were preferentially located far from the electrode. During NMES, new muscular regions situated far from the stimulation site are recruited. These recruitment mechanisms are particular and contrast with the recruitment of motor units seen during voluntary contraction. Copyright 2002 by the American Congress of Rehabilitation Medicine and the American Academy of Physical Medicine and Rehabilitation

  17. Very Preterm Infants Failing CPAP Show Signs of Fatigue Immediately after Birth.

    PubMed

    Siew, Melissa L; van Vonderen, Jeroen J; Hooper, Stuart B; te Pas, Arjan B

    2015-01-01

    To investigate the differences in breathing pattern and effort in infants at birth who failed or succeeded on continuous positive airway pressure (CPAP) during the first 48 hours after birth. Respiratory function recordings of 32 preterm infants were reviewed of which 15 infants with a gestational age of 28.6 (0.7) weeks failed CPAP and 17 infants with a GA of 30.1 (0.4) weeks did not fail CPAP. Frequency, duration and tidal volumes (VT) of expiratory holds (EHs), peak inspiratory flows, CPAP-level and FiO2-levels were analysed. EH incidence increased <6 minutes after birth and remained stable thereafter. EH peak inspiratory flows and VT were similar between CPAP-fail and CPAP-success infants. At 9-12 minutes, CPAP-fail infants more frequently used smaller VTs, 0-9 ml/kg and required higher peak inspiratory flows. However, CPAP-success infants often used large VTs (>9 ml/kg) with higher peak inspiratory flows than CPAP-fail infants (71.8 ± 15.8 vs. 15.5 ± 5.2 ml/kg.s, p <0.05). CPAP-fail infants required higher FiO2 (0.31 ± 0.03 vs. 0.21 ± 0.01), higher CPAP pressures (6.62 ± 0.3 vs. 5.67 ± 0.26 cmH2O) and more positive pressure-delivered breaths (45 ± 12 vs. 19 ± 9%) (p <0.05). At 9-12 minutes after birth, CPAP-fail infants more commonly used lower VTs and required higher peak inspiratory flow rates while receiving greater respiratory support. VT was less variable and larger VT was infrequently used reflecting early signs of fatigue.

  18. Cerebral ischemia and reperfusion increases the heterogeneity of local oxygen supply/consumption balance.

    PubMed

    Weiss, Harvey R; Grayson, Jeremy; Liu, Xia; Barsoum, Sylviana; Shah, Harsh; Chi, Oak Z

    2013-09-01

    After cerebral vessel blockage, local blood flow and O2 consumption becomes lower and oxygen extraction increases. With reperfusion, blood flow is partially restored. We examined the effects of ischemia-reperfusion on the heterogeneity of local venous oxygen saturation in rats in order to determine the pattern of microregional O2 supply/consumption balance in reperfusion. The middle cerebral artery was blocked for 1 hour using the internal carotid approach in 1 group (n=9) and was then reperfused for 2 hours in another group (n=9) of isoflurane-anesthetized rats. Regional cerebral blood flow was determined using a C(14)-iodoantipyrine autoradiographic technique. Regional small vessel arterial and venous oxygen saturations were determined microspectrophotometrically. After 1 hour of ischemia, local cerebral blood flow (92±10 versus 50±10 mL/min per 100 g) and O2 consumption (4.5±0.6 versus 2.7±0.5 mL O2/min per 100 g) decreased compared with the contralateral cortex. Oxygen extraction increased (4.7±0.2 versus 5.4±0.3 mL O2/100 mL) and the variation in small vein (20-60 μm) O2 saturation as determined by its coefficient of variation (=100×SD/mean) increased (5.5 versus 10.5). With 2 hours of reperfusion, the blood flow decrement was reduced and O2 consumption returned to the value in the contralateral cortex. Oxygen extraction remained elevated in the ischemic-reperfused area and the coefficient of variation of small vein O2 saturation increased further (17.3). These data indicated continued reduction of O2 supply/consumption balance with reperfusion. They also demonstrated many small regions of low oxygenation within the reperfused cortical region.

  19. Impact of a Geometric Correction for Proximal Flow Constraint on the Assessment of Mitral Regurgitation Severity Using the Proximal Flow Convergence Method.

    PubMed

    Jang, Jeong Yoon; Kang, Joon-Won; Yang, Dong Hyun; Lee, Sahmin; Sun, Byung Joo; Kim, Dae-Hee; Song, Jong-Min; Kang, Duk-Hyun; Song, Jae-Kwan

    2018-03-01

    Overestimation of the severity of mitral regurgitation (MR) by the proximal isovelocity surface area (PISA) method has been reported. We sought to test whether angle correction (AC) of the constrained flow field is helpful to eliminate overestimation in patients with eccentric MR. In a total of 33 patients with MR due to prolapse or flail mitral valve, both echocardiography and cardiac magnetic resonance image (CMR) were performed to calculate regurgitant volume (RV). In addition to RV by conventional PISA (RV PISA ), convergence angle (α) was measured from 2-dimensional Doppler color flow maps and RV was corrected by multiplying by α/180 (RV AC ). RV measured by CMR (RV CMR ) was used as a gold standard, which was calculated by the difference between total stroke volume measured by planimetry of the short axis slices and aortic stroke volume by phase-contrast image. The correlation between RV CMR and RV by echocardiography was modest [RV CMR vs. RV PISA (r = 0.712, p < 0.001) and RV CMR vs. RV AC (r = 0.766, p < 0.001)]. However, RV PISA showed significant overestimation (RV PISA - RV CMR = 50.6 ± 40.6 mL vs. RV AC - RV CMR = 7.7 ± 23.4 mL, p < 0.001). The overall accuracy of RV PISA for diagnosis of severe MR, defined as RV ≥ 60 mL, was 57.6% (19/33), whereas it increased to 84.8% (28/33) by using RV AC ( p = 0.028). Conventional PISA method tends to provide falsely large RV in patients with eccentric MR and a simple geometric AC of the proximal constraint flow largely eliminates overestimation.

  20. In vitro cytotoxicity of orthodontic primers.

    PubMed

    D'Antò, Vincenzo; Spagnuolo, Gianrico; Polito, Ilaria; Paduano, Sergio; Ambrosio, Luigi; Valletta, Rosa

    2009-01-01

    The aim of this study was to evaluate the cytotoxicity of four orthodontic primers: Transbond XT and Transbond MIP (3M, USA), Eagle Fluorsure (American Orthodontics, USA) and Ortho Solo (Ormco, USA). Balb 3T3 cells were exposed to different concentrations of primers (0-0.25 mg/ml). Mitochondrial dehydrogenase activity was evaluated by MTT assay and cell necrosis was measured by flow cytometry (propidium iodide staining). All the materials decreased cell viability in a dose related manner. Cytotoxicity of orthodontic primers based on concentrations which caused a 50% decrease of mitochondrial activity was ranked as follows: Transbond XT (45.57 mg/ml) > Eagle Fluorsure (49.27 mg/ml) > Transbond MIP (64.35 mg/ml) > Ortho solo (70.09 mg/ml). Our results suggest that the cytotoxic potencies demonstrated by orthodontic primers might be of clinical relevance since they disturbed cell metabolism and induced cell death in monolayer cultures.

  1. CBF measured by Xe-CT: Approach to analysis and normal values

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yonas, H.; Darby, J.M.; Marks, E.C.

    1991-09-01

    Normal reference values and a practical approach to CBF analysis are needed for routine clinical analysis and interpretation of xenon-enhanced computed tomography (CT) CBF studies. The authors measured CBF in 67 normal individuals with the GE 9800 CT scanner adapted for CBF imaging with stable Xe. CBF values for vascular territories were systematically analyzed using the clustering of contiguous 2-cm circular regions of interest (ROIs) placed within the cortical mantle and basal ganglia. Mixed cortical flows averaged 51 {plus minus} 10ml.100g-1.min-1. High and low flow compartments, sampled by placing 5-mm circular ROIs in regions containing the highest and lowest flowmore » values in each hemisphere, averaged 84 {plus minus} 14 and 20 {plus minus} 5 ml.100 g-1.min-1, respectively. Mixed cortical flow values as well as values within the high flow compartment demonstrated significant decline with age; however, there were no significant age-related changes in the low flow compartment. The clustering of systematically placed cortical and subcortical ROIs has provided a normative data base for Xe-CT CBF and a flexible and uncomplicated method for the analysis of CBF maps generated by Xe-enhanced CT.« less

  2. Development of polyvinyl acetate thin films by electrospinning for sensor applications

    NASA Astrophysics Data System (ADS)

    Veerabhadraiah, Amith; Ramakrishna, Sridhar; Angadi, Gangadhar; Venkatram, Mamtha; Kanivebagilu Ananthapadmanabha, Vishnumurthy; Hebbale NarayanaRao, Narasimha Murthy; Munishamaiah, Krishna

    2017-10-01

    Electrospinning is an effective process for synthesis of polymer fibers with diameters ranging between nanometers and micrometers by employing electrostatic force developed due to application of high voltage. The present work aims to develop an electrospinning system and optimize the process parameters for synthesis of Polyvinyl Acetate thin films used for gas and humidity sensors. Taguchi's Design of Experiment was adopted considering three main factors at three different levels for optimization of process parameters. The factors considered were flow rate (0.5, 0.6 and 0.7 ml/h), voltage (18, 19 and 20 kV) and spinneret to collector distance (8, 9, 10 cm) with fiber diameter as the response factor. The main effect plots and interaction plots of the parameters were studied to determine the most influencing parameter. Flow rate was the most significant factor followed by spinneret to collector distance. Least fiber diameter of 24.83 nm was observed at 19 kV, 0.5 ml/h flow rate and 8 cm spinneret to collector distance. SEM images revealed uniform fiber diameter at lower flow rate while bead formation increased monotonically with rise in flow rate.

  3. Lung assist device technology with physiologic blood flow developed on a tissue engineered scaffold platform.

    PubMed

    Hoganson, David M; Pryor, Howard I; Bassett, Erik K; Spool, Ira D; Vacanti, Joseph P

    2011-02-21

    There is no technology available to support failing lung function for patients outside the hospital. An implantable lung assist device would augment lung function as a bridge to transplant or possible destination therapy. Utilizing biomimetic design principles, a microfluidic vascular network was developed for blood inflow from the pulmonary artery and blood return to the left atrium. Computational fluid dynamics analysis was used to optimize blood flow within the vascular network. A micro milled variable depth mold with 3D features was created to achieve both physiologic blood flow and shear stress. Gas exchange occurs across a thin silicone membrane between the vascular network and adjacent alveolar chamber with flowing oxygen. The device had a surface area of 23.1 cm(2) and respiratory membrane thickness of 8.7 ± 1.2 μm. Carbon dioxide transfer within the device was 156 ml min(-1) m(-2) and the oxygen transfer was 34 ml min(-1) m(-2). A lung assist device based on tissue engineering architecture achieves gas exchange comparable to hollow fiber oxygenators yet does so while maintaining physiologic blood flow. This device may be scaled up to create an implantable ambulatory lung assist device.

  4. [Determination of residual solvents in 7-amino-3-chloro cephalosporanic acid by gas chromatography].

    PubMed

    Ma, Li; Yao, Tong-wei

    2011-01-01

    To develop a gas chromatography method for determination of residual solvents in 7-amino-3-chloro cephalosporanic acid (7-ACCA). The residual levels of acetone, methanol, dichloromethane, ethyl acetate, isobutanol, pyridine and toluene in 7-ACCA were measured by gas chromatography using Agilent INNOWAX capillary column (30 m × 0.32 mm,0.5 μm). The initial column temperature was 70° maintained for 6 min and then raised (10°C/min) to 160°C for 1 min. Nitrogen gas was used as carrier and FID as detector. The flow of carrier was 1.0 ml/min, the temperature of injection port and detector was 200°C and 250°C, respectively. The limits of detection for acetone, methanol, dichloromethane, ethyl acetate, isobutanol, pyridine, toluene in 7-ACCA were 2.5 μg/ml, 1.5 μg/ml, 15 μg/ml, 2.5 μg/ml, 2.5 μg/ml, 2.5 μg/ml and 11 μg/ml, respectively. Only acetone was detected in the sample, and was less than the limits of Ch.P. The method can effectively detect the residual solvents in 7-ACCA.

  5. Efficiency of the Thermal Jacket on the Delivered Temperature of Prewarmed Crystalloid Intravenous Fluid

    DTIC Science & Technology

    1989-01-01

    intervals over a 60 minute period at flow rates of 100, 250, 500, 750, and 1,000 ml/hr. Analysis of variance showed a highly significant group effect with a...significant difference between all groups except Group 3 and Group 4. Analysis of - .riance aiso showed a highly significant flow rate effect on...as effective as the conventional method of delivering warmed fluids. Also, within the range of flow rates studied, faster flow rates tended to yield a

  6. Bioreactor-based bone tissue engineering: The influence of dynamic flow on osteoblast phenotypic expression and matrix mineralization

    PubMed Central

    Yu, Xiaojun; Botchwey, Edward A.; Levine, Elliot M.; Pollack, Solomon R.; Laurencin, Cato T.

    2004-01-01

    An important issue in tissue engineering concerns the possibility of limited tissue ingrowth in tissue-engineered constructs because of insufficient nutrient transport. We report a dynamic flow culture system using high-aspect-ratio vessel rotating bioreactors and 3D scaffolds for culturing rat calvarial osteoblast cells. 3D scaffolds were designed by mixing lighter-than-water (density, <1g/ml) and heavier-than-water (density, >1g/ml) microspheres of 85:15 poly(lactide-co-glycolide). We quantified the rate of 3D flow through the scaffolds by using a particle-tracking system, and the results suggest that motion trajectories and, therefore, the flow velocity around and through scaffolds in rotating bioreactors can be manipulated by varying the ratio of heavier-than-water to lighter-than-water microspheres. When rat primary calvarial cells were cultured on the scaffolds in bioreactors for 7 days, the 3D dynamic flow environment affected bone cell distribution and enhanced cell phenotypic expression and mineralized matrix synthesis within tissue-engineered constructs compared with static conditions. These studies provide a foundation for exploring the effects of dynamic flow on osteoblast function and provide important insight into the design and optimization of 3D scaffolds suitable in bioreactors for in vitro tissue engineering of bone. PMID:15277663

  7. The utility of electron microscopy in detecting asbestos fibers and particles in BALF in diffuse lung diseases.

    PubMed

    Kido, Takashi; Morimoto, Yasuo; Yatera, Kazuhiro; Ishimoto, Hiroshi; Ogoshi, Takaaki; Oda, Keishi; Yamasaki, Kei; Kawanami, Toshinori; Shimajiri, Shohei; Mukae, Hiroshi

    2017-04-21

    In patients with diffuse lung diseases, differentiating occupational lung diseases from other diseases is clinically important. However, the value of assessing asbestos and particles in bronchoalveolar lavage fluid (BALF) in diffuse lung diseases by electron microscopy (EM) remains unclear. We evaluated the utility of EM in detecting asbestos fibers and particles in patients with diffuse lung diseases. The BALF specimens of 107 patients with diffuse lung diseases were evaluated. First, detection of asbestos by EM and light microscopy (LM) were compared. Second, the detection of asbestos using surgically obtained lung tissues of 8 of 107 patients were compared with the results of EM and LM in BALF. Third, we compared the results of mineralogical components of particles in patients with (n = 48) and without (n = 59) a history of occupational exposure to inorganic dust. BALF asbestos were detected in 11 of 48 patients with a history of occupational exposure by EM; whereas asbestos as asbestos bodies (ABs) were detected in BALF in 4 of these 11 patients by LM. Eight of 107 patients in whom lung tissue samples were surgically obtained, EM detected BALF asbestos at a level of >1,000 fibers/ml in all three patients who had ABs in lung tissue samples by LM at a level of >1,000 fibers/g. The BALF asbestos concentration by EM and in lung tissue by LM were positively correlated. The particle fractions of iron and phosphorus were increased in patients with a history of occupational exposure and both correlated with a history of occupational exposure by a multiple regression analysis. EM using BALF seemed to be superior to LM using BALF and displayed a similar sensitivity to LM using surgically-obtained lung tissue samples in the detection of asbestos. Our results also suggest that detection of elements, such as iron and phosphorus in particles, is useful for evaluating occupational exposure. We conclude that the detection of asbestos and iron and phosphorus in particles in BALF by EM is very useful for the evaluation of occupational exposure.

  8. Vasorelaxant and Hypotensive Effects of an Ethanolic Extract of Eulophia macrobulbon and Its Main Compound 1-(4′-Hydroxybenzyl)-4,8-Dimethoxyphenanthrene-2,7-Diol

    PubMed Central

    Wisutthathum, Sutthinee; Chootip, Krongkarn; Martin, Hélène; Ingkaninan, Kornkanok; Temkitthawon, Prapapan; Totoson, Perle; Demougeot, Céline

    2018-01-01

    Background: Ethnopharmacological studies demonstrated the potential for Eulophia species to treat inflammation, cancer, and cardio-metabolic diseases. The aim of the study was to investigate the vasorelaxant effect of ethanolic Eulophia macrobulbon (EM) extract and its main phenanthrene on rat isolated mesenteric artery and to investigate the hypotensive effect of EM. Methods: The vasorelaxant effects of EM extract or phenanthrene and the underlying mechanisms were evaluated on second-order mesenteric arteries from Sprague Dawley rats. In addition, the acute hypotensive effect was evaluated in anesthetized rats infused with cumulative concentrations of the EM extract. Results: Both EM extract (10-4–1 mg/ml) and phenanthrene (10-7–10-4 M) relaxed endothelium-intact arteries, an effect that was partly reduced by endothelium removal (p < 0.001). A significant decrease in the relaxant effect of the extract and the phenanthrene was observed with L-NAME and apamin/charybdotoxin in endothelium-intact vessels, and with iberiotoxin in denuded vessels. SNP (sodium nitroprusside)-induced relaxation was significantly enhanced by EM extract and phenanthrene. By contrast, ODQ (1H-[1,2,4]oxadiazolo[4,3-a]quinoxaline-1-one), 4-aminopyridine and glibenclamide (endothelium-denuded vessels) and indomethacin (endothelium-intact vessels) had no effect. In calcium-free solution, both the EM extract and phenanthrene inhibited extracellular Ca2+-induced contraction in high KCl and phenylephrine (PE) pre-contracted rings. They also inhibited the intracellular Ca2+ release sensitive to PE. The acute infusion of EM extract (20 and 70 mg/kg) induced an immediate and transient dose-dependent hypotensive effect. Conclusion: The ethanolic extract of EM tubers and its main active compound, 1-(4′-hydroxybenzyl)-4,8-dimethoxyphenanthrene-2,7-diol (phenanthrene) induced vasorelaxant effects on rat resistance vessels, through pleiotropic effects including endothelium-dependent effects (NOS activation, enhanced EDH production) and endothelium-independent effects (opening of KCa channels, inhibition of Ca2+ channels, inhibition of intracellular Ca2+ release and PDE inhibition). PMID:29872393

  9. Quantitative assessment of colorectal cancer tumor vascular parameters by using perfusion CT: influence of tumor region of interest.

    PubMed

    Goh, Vicky; Halligan, Steve; Gharpuray, Anita; Wellsted, David; Sundin, Josefin; Bartram, Clive I

    2008-06-01

    To prospectively determine whether position and size of tumor region of interest (ROI) influence estimates of colorectal cancer vascular parameters at computed tomography (CT). After institutional review board approval and informed consent, 25 men and 22 women (mean age, 65.8 years) with colorectal adenocarcinoma underwent 65-second CT perfusion study. Blood volume, blood flow, and permeability-surface area product were determined for 40- or 120-mm(2) circular ROIs placed at the tumor edge and center and around (outlining) visible tumor. ROI analysis was repeated by two observers in different subsets of patients to assess intra- and interobserver variation. Measurements were compared by using analysis of variance; a difference with P = .002 was significant. Blood volume, blood flow, and permeability-surface area product measurements were substantially higher at the edge than at the center for both 40- and 120-mm(2) ROIs. For 40-mm(2) ROI, means of the three measurements were 6.9 mL/100 g (standard deviation [SD], 1.4), 108.7 mL/100 g per minute (SD, 39.2), and 16.9 mL/100 g per minute (SD, 4.2), respectively, at the edge versus 5.1 mL/100 g (SD, 1.5), 56.3 mL/100 g per minute (SD, 33.1), and 13.9 mL/100 g per minute (SD, 4.6), respectively, at the center. For 120-mm(2) ROI, means of the three measurements were 6.6 mL/100 g (SD, 1.3), 96.7 mL/100 g per minute (SD, 42.5), and 16.3 mL/100 g per minute (SD, 5.6), respectively, at the edge versus 5.1 mL/100 g (SD, 1.4), 58.3 mL/100 g per minute (SD, 32.5), and 13.4 mL/100 g per minute (SD, 4.3) at the center (P < .0001). Measurements varied substantially depending on the ROI size; values for the ROI for outlined tumor were intermediate between those at the tumor edge and center. Inter- and intraobserver agreement was poor for both 40- and 120-mm(2) ROIs. Position and size of tumor ROI and observer variation substantially influence ultimate perfusion values. ROI for outlined entire tumor is more reliable for perfusion measurements and more appropriate clinically than use of arbitrarily determined smaller ROIs. (c) RSNA, 2008.

  10. Seismicity Induced by Water Injection for Geothermal Reservoir Stimulation 5 km Below the City of Basel, Switzerland

    NASA Astrophysics Data System (ADS)

    Deichmann, N.; Mai, M.; Bethmann, F.; Ernst, J.; Evans, K.; Fäh, D.; Giardini, D.; Häring, M.; Husen, S.; Kästli, P.; Bachmann, C.; Ripperger, J.; Schanz, U.; Wiemer, S.

    2007-12-01

    To stimulate the reservoir for a proposed "hot dry rock" geothermal project in the city of Basel, approximately 11500 m3 of water were injected between December 2nd and 8th, 2006, at high pressures into a 5 km deep well. A six-sensor borehole array, installed at depths between 300 and 2700 meters around the well to monitor the induced seismicity, recorded more than 10500 events during the injection phase. Events with magnitudes as low as ML 0.7 were also recorded by regional networks in Switzerland, Germany and France, as well as by up to 30 strong-motion stations installed in the epicentral area. Due to excessive seismic activity, that included an ML 2.7 event, injection had already been stopped when a few hours later an ML 3.4 event jolted the city of Basel. A large amount of (non-structural) damage, corresponding to an intensity of V (EMS98), has been claimed by home owners. The unusual number of damage claims compared to past events in this magnitude range observed in Switzerland is partly due to the shallow hypocenter (5 km) beneath a densely populated city. In addition, ground-motion modelling shows that the radiation pattern of the earthquake source was oriented unfavourably for the city of Basel and that in numerous locations shaking was amplified significantly by local site conditions. After bleed-off, about one third of the injected water volume flowed back out of the well. Although seismic activity declined rapidly thereafter, three additional ML>3 events occurred over the following two months. From a statistical analysis it is expected that it may take on the order of a decade for the activity to decrease to the regional background level scaled to the size of the source region. The hypocenters of the located events (about 3500 to date) are restricted to a NW-SE oriented lens-shaped cloud, about 1 km in diameter and 200 m wide, with a single offsetting branch to the ESE. The orientation of the cloud and the focal mechanisms determined so far match the stress field derived from observations of borehole breakouts and natural seismicity. Due to the premature abortion of the stimulation process, the size of the stimulated volume is insufficient for a commercially viable exploitation of geothermal energy. At present the project is on hold, pending a comprehensive assessment of the seismic risk associated with a continuation.

  11. Limb Blood Flow After Class 4 Laser Therapy

    PubMed Central

    Larkin, Kelly A.; Martin, Jeffrey S.; Zeanah, Elizabeth H.; True, Jerry M.; Braith, Randy W.; Borsa, Paul A.

    2012-01-01

    Context: Laser therapy is purported to improve blood flow in soft tissues. Modulating circulation would promote healing by controlling postinjury ischemia, hypoxia, edema, and secondary tissue damage. However, no studies have quantified these responses to laser therapy. Objective: To determine a therapeutic dose range for laser therapy for increasing blood flow to the forearm. Design: Crossover study. Setting: Controlled laboratory setting. Patients or Other Participants: Ten healthy, college-aged men (age = 20.80 ± 2.16 years, height = 177.93 ± 3.38 cm, weight = 73.64 ± 9.10 kg) with no current history of injury to the upper extremity or cardiovascular conditions. Intervention(s): A class 4 laser device was used to treat the biceps brachii muscle. Each grid point was treated for 3 to 4 seconds, for a total of 4 minutes. Each participant received 4 doses of laser therapy: sham, 1 W, 3 W, and 6 W. Main Outcome Measure(s): The dependent variables were changes in blood flow, measured using venous occlusion plethysmography. We used a repeated-measures analysis of variance to analyze changes in blood flow for each dose at 2, 3, and 4 minutes and at 1, 2, 3, 4, and 5 minutes after treatment. The Huynh-Feldt test was conducted to examine differences over time. Results: Compared with baseline, blood flow increased over time with the 3-W treatment (F3,9 = 3.468, P < .011) at minute 4 of treatment (2.417 ± 0.342 versus 2.794 ± 0.351 mL/min per 100 mL tissue, P = .032), and at 1 minute (2.767 ± 0.358 mL/min per 100 mL tissue, P < .01) and 2 minutes (2.657 ± 0.369 mL/min per 100 mL tissue, P = .022) after treatment. The sham, 1-W, and 6-W treatment doses did not change blood flow from baseline at any time point. Conclusions: Laser therapy at the 3-W (360-J) dose level was an effective treatment modality to increase blood flow in the soft tissues. PMID:22488283

  12. Behavior of radio frequency electric fields injured Escherichia coli in nutrient and non nutrient media during storage

    USDA-ARS?s Scientific Manuscript database

    Information on conditions required for resuscitation of Radio Frequency Electric Fields (RFEF) damaged E. coli cells is limited. Apple juice inoculated with Escherichia coli K-12 at 7.8 log CFU/ml was treated with RFEF at 20 kHz, 15 kV/cm for 170 micro second at 55C with a flow rate of 540 ml/min. A...

  13. Left Ventricular Stroke Volume Quantification by Contrast Echocardiography – Comparison of Linear and Flow-Based Methods to Cardiac Magnetic Resonance

    PubMed Central

    Dele-Michael, Abiola O.; Fujikura, Kana; Devereux, Richard B; Islam, Fahmida; Hriljac, Ingrid; Wilson, Sean R.; Lin, Fay; Weinsaft, Jonathan W.

    2014-01-01

    Background Echocardiography (echo) quantified LV stroke volume (SV) is widely used to assess systolic performance after acute myocardial infarction (AMI). This study compared two common echo approaches – predicated on flow (Doppler) and linear chamber dimensions (Teichholz) – to volumetric SV and global infarct parameters quantified by cardiac magnetic resonance (CMR). Methods Multimodality imaging was performed as part of a post-AMI registry. For echo, SV was measured by Doppler and Teichholz methods. Cine-CMR was used for volumetric SV and LVEF quantification, and delayed-enhancement CMR for infarct size. Results 142 patients underwent same-day echo and CMR. On echo, mean SV by Teichholz (78±17ml) was slightly higher than Doppler (75±16ml; Δ=3±13ml, p=0.02). Compared to SV on CMR (78±18ml), mean difference by Teichholz (Δ=−0.2±14; p=0.89) was slightly smaller than Doppler (Δ−3±14; p=0.02) but limits of agreement were similar between CMR and echo methods (Teichholz: −28, 27 ml, Doppler: −31, 24ml). For Teichholz, differences with CMR SV were greatest among patients with anteroseptal or lateral wall hypokinesis (p<0.05). For Doppler, differences were associated with aortic valve abnormalities or root dilation (p=0.01). SV by both echo methods decreased stepwise in relation to global LV injury as assessed by CMR-quantified LVEF and infarct size (p<0.01). Conclusions Teichholz and Doppler calculated SV yield similar magnitude of agreement with CMR. Teichholz differences with CMR increase with septal or lateral wall contractile dysfunction, whereas Doppler yields increased offsets in patients with aortic remodeling. PMID:23488864

  14. Quantitative colorectal cancer perfusion measurement by multidetector-row CT: does greater tumour coverage improve measurement reproducibility?

    PubMed

    Goh, V; Halligan, S; Gartner, L; Bassett, P; Bartram, C I

    2006-07-01

    The purpose of this study was to determine if greater z-axis tumour coverage improves the reproducibility of quantitative colorectal cancer perfusion measurements using CT. A 65 s perfusion study was acquired following intravenous contrast administration in 10 patients with proven colorectal cancer using a four-detector row scanner. This was repeated within 48 h using identical technical parameters to allow reproducibility assessment. Quantitative tumour blood volume, blood flow, mean transit time and permeability measurements were determined using commercially available software (Perfusion 3.0; GE Healthcare, Waukesha, WI) for data obtained from a 5 mm z-axis tumour coverage, and from a 20 mm z-axis tumour coverage. Measurement reproducibility was assessed using Bland-Altman statistics, for a 5 mm z-axis tumour coverage, and 20 mm z-axis tumour coverage, respectively. The mean difference (95% limits of agreement) for blood volume, blood flow, mean transit time and permeability were 0.04 (-2.50 to +2.43) ml/100 g tissue; +8.80 (-50.5 to +68.0) ml/100 g tissue/min; -0.99 (-8.19 to +6.20) seconds; and +1.20 (-5.42 to +7.83) ml/100 g tissue/min, respectively, for a 5 mm coverage, and -0.04 (-2.61 to +2.53) ml/100 g tissue; +7.40 (-50.3 to +65.0) ml/100 g tissue/min; -2.46 (-12.61 to +7.69) seconds; and -0.23 (-8.31 to +7.85) ml/100 g tissue/min, respectively, for a 20 mm coverage, indicating similar levels of agreement. In conclusion, increasing z-axis coverage does not improve reproducibility of quantitative colorectal cancer perfusion measurements.

  15. Validation of real-time three-dimensional echocardiography for quantifying left ventricular volumes in the presence of a left ventricular aneurysm: in vitro and in vivo studies

    NASA Technical Reports Server (NTRS)

    Qin, J. X.; Jones, M.; Shiota, T.; Greenberg, N. L.; Tsujino, H.; Firstenberg, M. S.; Gupta, P. C.; Zetts, A. D.; Xu, Y.; Ping Sun, J.; hide

    2000-01-01

    OBJECTIVES: To validate the accuracy of real-time three-dimensional echocardiography (RT3DE) for quantifying aneurysmal left ventricular (LV) volumes. BACKGROUND: Conventional two-dimensional echocardiography (2DE) has limitations when applied for quantification of LV volumes in patients with LV aneurysms. METHODS: Seven aneurysmal balloons, 15 sheep (5 with chronic LV aneurysms and 10 without LV aneurysms) during 60 different hemodynamic conditions and 29 patients (13 with chronic LV aneurysms and 16 with normal LV) underwent RT3DE and 2DE. Electromagnetic flow meters and magnetic resonance imaging (MRI) served as reference standards in the animals and in the patients, respectively. Rotated apical six-plane method with multiplanar Simpson's rule and apical biplane Simpson's rule were used to determine LV volumes by RT3DE and 2DE, respectively. RESULTS: Both RT3DE and 2DE correlated well with actual volumes for aneurysmal balloons. However, a significantly smaller mean difference (MD) was found between RT3DE and actual volumes (-7 ml for RT3DE vs. 22 ml for 2DE, p = 0.0002). Excellent correlation and agreement between RT3DE and electromagnetic flow meters for LV stroke volumes for animals with aneurysms were observed, while 2DE showed lesser correlation and agreement (r = 0.97, MD = -1.0 ml vs. r = 0.76, MD = 4.4 ml). In patients with LV aneurysms, better correlation and agreement between RT3DE and MRI for LV volumes were obtained (r = 0.99, MD = -28 ml) than between 2DE and MRI (r = 0.91, MD = -49 ml). CONCLUSIONS: For geometrically asymmetric LVs associated with ventricular aneurysms, RT3DE can accurately quantify LV volumes.

  16. Segmental microvascular permeability in ischemia-reperfusion injury in rat lung.

    PubMed

    Khimenko, P L; Taylor, A E

    1999-06-01

    Segmental microvascular permeabilities were measured using pre- and postalveolar vessel capillary filtration coefficient (Kfc) values (ml. min-1. cmH2O-1. 100 g-1) in isolated rat lungs subjected to ischemia-reperfusion (I/R). Total Kfc values measured in flowing and nonflowing lungs were highly correlated (r = 0.98, P < 0.0001). Kfc values were then measured in another group of lungs under no-flow conditions when airway pressure was increased to 20 cmH2O and either the arterial or venous pressure was elevated to 7-8 cmH2O to measure the prealveolar and postalveolar Kfc values. Control total and postalveolar Kfc values were 0.0225 +/- 0.001 and 0.0219 +/- 0.001 ml. min-1. cmH2O-1. 100 g-1, respectively, and the prealveolar permeability was extremely small (0.00003 +/- 0.00005 ml. min-1. cmH2O-1. 100 g-1). Kfc values were again made in nonflowing lungs that had been subjected to 45 min of ischemia followed by 30 min of reperfusion. After I/R, the total membrane Kfc increased 10-fold to 0.2597 +/- 0.006 ml. min-1. cmH2O-1. 100 g-1, the prealveolar Kfc increased to 0.0677 +/- 0.003 ml. min-1. cmH2O-1. 100 g-1, and the postalveolar Kfc increased to 0.1354 +/- 0.008 ml. min-1. cmH2O-1. 100 g-1 (P < 0.05 for all I/R values). These data indicate that normal solvent microvascular permeability was predominantly postalveolar, and after I/R damage, the postalveolar (venular) permeability comprised 52% of the total, whereas the prealveolar and alveolar vessels comprised only 27 and 23%, respectively, of the total Kfc.

  17. Effects of influent strength on microorganisms in surface flow mesocosm wetlands.

    PubMed

    Tao, Wendong; Hall, Ken J; Ramey, William

    2007-11-01

    To choose an appropriate dilution ratio to treat woodwaste leachate without inhibition on heterotrophic bacteria, microbial ATP concentration and the rates of heterotrophic leucine incorporation and acetate uptake were compared across surface flow mesocosm wetlands fed with different strengths of influent. Abundances of protozoa and respiring bacteria were investigated in two mesocosm wetlands to elucidate the effects of influent strength on heterotrophic bacteria. The strongest influent or the raw leachate did not show a significant inhibitory effect on leucine incorporation and acetate uptake. Instead, leucine incorporation rates by bacteria in water, epiphytic biofilm and sediment were higher in mesocosm wetlands fed with a stronger influent. There were significantly more respiring planktonic bacteria (451 x 10(5) mL(-1)) and fewer nanoflagellates (3.8 x 10(3) mL(-1)) in the mesocosm fed with a strong influent, while fewer respiring planktonic bacteria (38.7 x 10(5)mL(-1)) and more nanoflagellates (15.4 x 10(3) mL(-1)) in the mesocosm fed with a weak influent. The majority of the total microbial ATP was attributed to sedimentary bacteria, of which >96% were inactive. Heterotrophic activity and its distribution among water, epiphytic biofilm and sediment in the mesocosm wetlands were affected by availability of bacterial substrates and grazing pressure of nanoflagellates.

  18. Effects of Verbal Cue on Bolus Flow during Swallowing

    ERIC Educational Resources Information Center

    Daniels, Stephanie K.; Schroeder, Mae Fern; DeGeorge, Pamela C.; Corey, David M.; Rosenbek, John C.

    2007-01-01

    Purpose: To examine the effects of verbal cuing to initiate swallowing on bolus flow measures in healthy adults. Method: Videofluoroscopic examinations were completed in 12 healthy older adults (median age = 69 years) as they swallowed 5 ml of self-administered liquid barium in 2 conditions: verbally cued and noncued swallows. In the cued…

  19. Determination of albumin in bronchoalveolar lavage fluid by flow-injection fluorometry using chromazurol S.

    PubMed

    Sato, Takaji; Saito, Yoshihiro; Chikuma, Masahiko; Saito, Yutaka; Nagai, Sonoko

    2008-03-01

    A highly sensitive flow injection fluorometry for the determination of albumin was developed and applied to the determination of albumin in human bronchoalveolar lavage fluids (BALF). This method is based on binding of chromazurol S (CAS) to albumin. The calibration curve was linear in the range of 5-200 microg/ml of albumin. A highly linear correlation (r=0.986) was observed between the albumin level in BALF samples (n=25) determined by the proposed method and by a conventional fluorometric method using CAS (CAS manual method). The IgG interference was lower in the CAS flow injection method than in the CAS manual method. The albumin level in BALF collected from healthy volunteers (n=10) was 58.5+/-13.1 microg/ml. The albumin levels in BALF samples obtained from patients with sarcoidosis and idiopathic pulmonary fibrosis were increased. This finding shows that the determination of albumin levels in BALF samples is useful for investigating lung diseases and that CAS flow injection method is promising in the determination of trace albumin in BALF samples, because it is sensitive and precise.

  20. Production of acids and alcohols from syngas in a two-stage continuous fermentation process.

    PubMed

    Abubackar, Haris Nalakath; Veiga, María C; Kennes, Christian

    2018-04-01

    A two-stage continuous system with two stirred tank reactors in series was utilized to perform syngas fermentation using Clostridium carboxidivorans. The first bioreactor (bioreactor 1) was maintained at pH 6 to promote acidogenesis and the second one (bioreactor 2) at pH 5 to stimulate solventogenesis. Both reactors were operated in continuous mode by feeding syngas (CO:CO 2 :H 2 :N 2 ; 30:10:20:40; vol%) at a constant flow rate while supplying a nutrient medium at different flow rates of 8.1, 15, 22 and 30 ml/h. A cell recycling unit was added to bioreactor 2 in order to recycle the cells back to the reactor, maintaining the OD 600 around 1 in bioreactor 2 throughout the experimental run. When comparing the flow rates, the best results in terms of solvent production were obtained with a flow rate of 22 ml/h, reaching the highest average outlet concentration for alcohols (1.51 g/L) and the most favorable alcohol/acid ratio of 0.32. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Small Molecule Inhibitors of ERG and ETV1 in Prostate Cancer

    DTIC Science & Technology

    2015-09-01

    Kong Y, Merchant M, Schlottmann S , Barber-Rotenberg JS, Yuan L, et al. A small molecule blocking oncogenic protein EWS -FLI1 interaction with RNA helicase...A inhibits growth of Ewing’s sarcoma . Nature medicine. 2009;15:750-6. 15. Rahim S , Beauchamp EM, Kong Y, Brown ML, Toretsky JA, Uren A. YK-4-279...The views, opinions and/or findings contained in this report are those of the author( s ) and should not be construed as an official Department of the

  2. Transactions of the Army Conference on Applied Mathematics and Computing (3rd) Held at Atlanta, Georgia on 13-16 May 1986

    DTIC Science & Technology

    1986-02-01

    jask 1 in (x,y) plane. Porn in Work Socca - Y” S,=2.0m -. I - .em Fig. 4b Task 2 in (x,y) plane. I IE:/lvli-r;: ILIldtili ml=m2= 2.0 kg...represented by a grid of 400x200 points, each point corresponding to a pixel of a computer video terminal. For each point A = (Re(A), ImW), a free critical

  3. High performance liquid chromatography coupled with resonance Rayleigh scattering for the detection of three fluoroquinolones and mechanism study

    NASA Astrophysics Data System (ADS)

    Zhou, Mingqiong; Peng, Jingdong; He, Rongxing; He, Yuting; Zhang, Jing; Li, Aiping

    2015-02-01

    A reliable and versatile high performance liquid chromatography coupled with resonance Rayleigh scattering method was established for the determination of three fluoroquinolones, including levofloxacin, norfloxacin and enrofloxacin in water sample and human urine sample. In pH 4.4-4.6 Britton-Robinson buffer medium, the fluoroquinolones separated by high performance liquid chromatography could react with erythrosine to form 1:1 ion-association complexes, which could make contributions to the great enhancement of RRS. The resonance Rayleigh scattering signal was recorded at λex = λem = 330 nm. The resonance Rayleigh scattering spectral characteristics of the drugs and the experimental conditions such as pH, detection wavelength, erythrosine concentration, flow rate, the length of reaction tube were studied. Quantum chemistry calculation, Fourier transform infrared spectroscopy and absorption spectroscopy were used to discuss the reaction mechanism. The recoveries of samples added standard ranged from 97.53% to 102.00%, and the relative standard deviation was below 4.64%. The limit of detection (S/N = 3) of 0.05-0.12 μg mL-1 was reached, and the linear regression coefficients were all above 0.999. The proposed method was proved as a simple, low cost and high sensitivity method.

  4. Hemodilution increases cerebral blood flow in acute ischemic stroke

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vorstrup, S.; Andersen, A.; Juhler, M.

    1989-07-01

    We measured cerebral blood flow in 10 consecutive, but selected, patients with acute ischemic stroke (less than 48 hours after onset) before and after hemodilution. Cerebral blood flow was measured by xenon-133 inhalation and emission tomography, and only patients with focal hypoperfusion in clinically relevant areas were included. Hemodilution was done according to the hematocrit level: for a hematocrit greater than or equal to 42%, 500 ml whole blood was drawn and replaced by the same volume of dextran 40; for a hematocrit between 37% and 42%, only 250 ml whole blood was drawn and replaced by 500 cc ofmore » dextran 40. Mean hematocrit was reduced by 16%, from 46 +/- 5% (SD) to 39 +/- 5% (SD) (p less than 0.001). Cerebral blood flow increased in both hemispheres by an average of 20.9% (p less than 0.001). Regional cerebral blood flow increased in the ischemic areas in all cases, on an average of 21.4 +/- 12.0% (SD) (p less than 0.001). In three patients, a significant redistribution of flow in favor of the hypoperfused areas was observed, and in six patients, the fractional cerebral blood flow increase in the hypoperfused areas was of the same magnitude as in the remainder of the brain. In the last patient, cerebral blood flow increased relatively less in the ischemic areas. Our findings show that cerebral blood flow increases in the ischemic areas after hemodilution therapy in stroke patients. The marked regional cerebral blood flow increase seen in some patients could imply an improved oxygen delivery to the ischemic tissue.« less

  5. Column study of chromium(VI) adsorption from electroplating industry by coconut coir pith.

    PubMed

    Suksabye, Parinda; Thiravetyan, Paitip; Nakbanpote, Woranan

    2008-12-15

    The removal of Cr(VI) from electroplating wastewater by coir pith was investigated in a fixed-bed column. The experiments were conducted to study the effect of important parameters such as bed depth (40-60cm) and flow rate (10-30ml min(-1)). At 0.05 C(t)/C(0), the breakthrough volume increased as flow rate decreased or a bed depth increased due to an increase in empty bed contact time (EBCT). The bed depth service time model (BDST) fit well with the experimental data in the initial region of the breakthrough curve, while the simulation of the whole curve using non-linear regression analysis was effective using the Thomas model. The adsorption capacity estimated from the BDST model was reduced with increasing flow rate, which was 16.40mg cm(-3) or 137.91mg Cr(VI)g(-1) coir pith for the flow rates of 10ml min(-1) and 14.05mg cm(-3) or 118.20mg Cr(VI)g(-1) coir pith for the flow rates of 30ml min(-1). At the highest bed depth (60cm) and the lowest flow rate (10mlmin(-1)), the maximum adsorption reached 201.47mg Cr(VI)g(-1) adsorbent according to the Thomas model. The column was regenerated by eluting chromium using 2M HNO(3) after adsorption studies. The desorption of Cr(III) in each of three cycles was about 67-70%. The desorption of Cr(III) in each cycle did not reach 100% due to the fact that Cr(V) was present through the reduction of Cr(VI), and was still in coir pith, possibly bound to glucose in the cellulose part of coir pith. Therefore, the Cr(V) complex cannot be desorbed in solution. The evidence of Cr(V) signal was observed in coir pith, alpha-cellulose and holocellulose extracted from coir pith using electron spin resonance (ESR).

  6. Bi-level CPAP does not change central blood flow in preterm infants with respiratory distress syndrome.

    PubMed

    Aquilano, Giulia; Galletti, Silvia; Aceti, Arianna; Vitali, Francesca; Faldella, Giacomo

    2014-06-21

    Current literature provides limited data on the hemodynamic changes that may occur during bi-level continuous positive airway pressure (CPAP) support in preterm infants. However, the application of a positive end-expiratory pressure may be transmitted to the heart and the great vessels resulting in changes of central blood flow. To assess changes in central blood flow in infants with respiratory distress syndrome (RDS) during bi-level CPAP support. A prospective study was performed in a cohort of 18 Very-Low-Birth-Weight Infants who were put on nasal CPAP support (4-5 cmH2O) because they developed RDS within the first 24-72 hours of life. Each subject was switched to bi-level CPAP support (Phigh 8 cmH2O, Plow 4-5 cmH2O, Thigh 0.5-0.6 seconds, 20 breaths/min) for an hour. An echocardiographic study and a capillary gas analysis were performed before and after the change of respiratory support. No differences between n-CPAP and bi-level CPAP in left ventricular output (LVO, 222.17 ± 81.4 vs 211.4 ± 75.3 ml/kg/min), right ventricular output (RVO, 287.8 ± 96 vs 283.4 ± 87.4 ml/kg/min) and superior vena cava flow (SVC, 135.38 ± 47.8 vs 137.48 ± 46.6 ml/kg/min) were observed. The hemodynamic characteristics of the ductus arteriosus were similar. A significant decrease in pCO2 levels after bi-level CPAP ventilation was observed; pCO2 variations did not correlate with modifications of central blood flow (LVO: ρ=0.11, p=0,657; RVO: ρ=-0.307, p=0.216; SVC: ρ=-0.13, p=0.197). Central blood flow doesn't change during bi-level CPAP support, which could become a hemodinamically safe tool for the treatment of RDS in preterm infants.

  7. Determination of VIT 45 (IND#63,243 - American Regent) removal by closed loop in vitro hemodialysis system.

    PubMed

    Manley, H J; McClaran, M L

    2006-11-01

    Intravenous iron is typically administered during the hemodialysis (HD) procedure. The extent of VIT 45, a novel intravenous iron formulation, removal by high-flux (HF) or high-efficiency (HE) dialysis membranes at various ultrafiltration rates (UFR) is unknown. An in vitro HD system was constructed to determine the dialyzability of iron from a normal saline compartment (NSC) containing 1000 mg iron of VIT 45. The in vitro system utilized a 6-L closed-loop SBS system that was subject to 4 different HD conditions conducted over 4 hours: HE membrane + 0 ml/h UFR; HE membrane + 500 ml/h UFR; HF membrane + 0 ml/h UFR; HF membrane + 500 ml/h UFR. Blood flow and dialysate flow rates were 500 ml/min and 800 ml/min, respectively. The dialysate compartment was a 6-L closed-loop system. A volumetric HD machine controlled all blood, dialysate, and ultrafiltration rates. NSC and dialysate compartment samples were taken at various time points and iron elimination rate (khd) and HD clearance (Clhd) was determined. Iron removal from the NSC > 15% was considered clinically significant. The percent removal of iron from the NSC was < 0.5% at all time points in the study. Dialysate recovery of iron was negligible: 1.7-5.1 mg. VIT 45 removal elimination rates from NSC were less than -0.001 h(-1) (range -0.0002 +/- 0.0001 to -0.0001 +/- 0.0002 h (-1)) for all study conditions. Dialyzer type or UFR did not effect iron removal. HF or HE dialysis membranes do not remove clinically significant amounts of VIT 45 over a 4-hour in vitro HD session. This effect remained constant even controlling for UFR up to 500 ml/hour. VIT 45 is not dialyzed by HE or HF dialysis membranes irrespective of UFR.

  8. Electromigration Critical Product to Measure Effect of Underfill Material in Suppressing Bi Segregation in Sn-58Bi Solder

    NASA Astrophysics Data System (ADS)

    Zhao, Xu; Takaya, Satoshi; Muraoka, Mikio

    2017-08-01

    Recently, we detected length-dependent electromigration (EM) behavior in Sn-58Bi (SB) solder and revealed the existence of Bi back-flow, which retards EM-induced Bi segregation and is dependent on solder length. The cause of the back-flow is attributed to an oxide layer formed on the SB solder. At present, underfill (UF) material is commonly used in flip-chip packaging as filler between chip and substrate to surround solder bumps. In this study, we quantitatively investigated the effect of UF material as a passivation layer on EM in SB solder strips. EM tests on SB solder strips with length of 50 μm, 100 μm, and 150 μm were conducted simultaneously. Some samples were coated with commercial thermosetting epoxy UF material, which acted as a passivation layer on the Cu-SB-Cu interconnections. The value of the critical product for SB solder was estimated to be 38 A/cm to 43 A/cm at 353 K to 373 K without UF coating and 59 A/cm at 373 K with UF coating. The UF material acting as a passivation layer suppressed EM-induced Bi segregation and increased the threshold current density by 37% to 55%. However, at very high current density, this effect became very slight. In addition, Bi atoms can diffuse to the anode side through the Sn phase, hence addition of microelements to the Sn phase to form obstacles, such as intermetallic compounds, may retard Bi segregation in SB solder.

  9. Detection of vesicoureteral reflux using microwave radiometry-system characterization with tissue phantoms.

    PubMed

    Arunachalam, Kavitha; Maccarini, Paolo; De Luca, Valeria; Tognolatti, Piero; Bardati, Fernando; Snow, Brent; Stauffer, Paul

    2011-06-01

    Microwave (MW) radiometry is proposed for passive monitoring of kidney temperature to detect vesicoureteral reflux (VUR) of urine that is externally heated by a MW hyperthermia device and thereafter reflows from the bladder to kidneys during reflux. Here, we characterize in tissue-mimicking phantoms the performance of a 1.375 GHz radiometry system connected to an electromagnetically (EM) shielded microstrip log spiral antenna optimized for VUR detection. Phantom EM properties are characterized using a coaxial dielectric probe and network analyzer (NA). Power reflection and receive patterns of the antenna are measured in layered tissue phantom. Receiver spectral measurements are used to assess EM shielding provided by a metal cup surrounding the antenna. Radiometer and fiberoptic temperature data are recorded for varying volumes (10-30 mL) and temperaturesg (40-46°C) of the urine phantom at 35 mm depth surrounded by 36.5°C muscle phantom. Directional receive pattern with about 5% power spectral density at 35 mm target depth and better than -10 dB return loss from tissue load are measured for the antenna. Antenna measurements demonstrate no deterioration in power reception and effective EM shielding in the presence of the metal cup. Radiometry power measurements are in excellent agreement with the temperature of the kidney phantom. Laboratory testing of the radiometry system in temperature-controlled phantoms supports the feasibility of passive kidney thermometry for VUR detection.

  10. Cine phase-contrast MRI evaluation of normal aqueductal cerebrospinal fluid flow according to sex and age.

    PubMed

    Unal, Ozkan; Kartum, Alp; Avcu, Serhat; Etlik, Omer; Arslan, Halil; Bora, Aydin

    2009-12-01

    The aim of this study was cerebrospinal flow quantification in the cerebral aqueduct using cine phase-contrast magnetic resonance imaging (MRI) technique in both sexes and five different age groups to provide normative data. Sixty subjects with no cerebral pathology were included in this study. Subjects were divided into five age groups: < or =14 years, 15-24 years, 25-34 years, 35-44 years, and > or =45 years. Phase, rephase, and magnitude images were acquired by 1.5 T MR unit at the level of cerebral aqueduct with spoiled gradient echo through-plane, which is a cine phase-contrast sequence. At this level, peak flow velocity (cm/s), average flow rate (cm/ s), average flow (L/min), volumes in cranial and caudal directions (mL), and net volumes (mL) were studied. There was a statistically significant difference in peak flow between the age group of < or =14 years and the older age groups. There were no statistically significant differences in average velocity, cranial and caudal volume, net volume, and average flow parameters among different age groups. Statistically significant differences were not detected in flow parameters between sexes. When using cine-phase contrast MRI in the cerebral aqueduct, only the peak velocity showed a statistically significant difference between age groups; it was higher in subjects aged < or =14 years than those in older age groups. When performing age-dependent clinical studies including adolescents, this should be taken into consideration.

  11. Surface-Cycling of Rhenium and its Isotopes

    DTIC Science & Technology

    2009-06-01

    Fisher Scientific) in the WHOI plasma facility. Samples were introduced using a PFA MicroFlow nebulizer (Elemental Scientific Incorporated), a quartz...Samples were introduced using a PFA MicroFlow nebulizer (Elemental Scientific Incorporated), a quartz spray chamber, and regular cones. Analyses are done in...189Os. Samples dissolved in 1 mL of 0.5 molL−1 HNO3 are introduced using a PFA MicroFlow nebulizer (Elemental Scientific Incorporated), a quartz spray

  12. A wearable artificial kidney for patients with end-stage renal disease

    PubMed Central

    Gura, Victor; Rivara, Matthew B.; Bieber, Scott; Munshi, Raj; Linke, Lori; Kundzins, John; Ezon, Carlos; Kessler, Larry

    2016-01-01

    BACKGROUND. Stationary hemodialysis machines hinder mobility and limit activities of daily life during dialysis treatments. New hemodialysis technologies are needed to improve patient autonomy and enhance quality of life. METHODS. We conducted a FDA-approved human trial of a wearable artificial kidney, a miniaturized, wearable hemodialysis machine, based on dialysate-regenerating sorbent technology. We aimed to determine the efficacy of the wearable artificial kidney in achieving solute, electrolyte, and volume homeostasis in up to 10 subjects over 24 hours. RESULTS. During the study, all subjects remained hemodynamically stable, and there were no serious adverse events. Serum electrolytes and hemoglobin remained stable over the treatment period for all subjects. Fluid removal was consistent with prescribed ultrafiltration rates. Mean blood flow was 42 ± 24 ml/min, and mean dialysate flow was 43 ± 20 ml/min. Mean urea, creatinine, and phosphorus clearances over 24 hours were 17 ± 10, 16 ± 8, and 15 ± 9 ml/min, respectively. Mean β2-microglobulin clearance was 5 ± 4 ml/min. Of 7 enrolled subjects, 5 completed the planned 24 hours of study treatment. The trial was stopped after the seventh subject due to device-related technical problems, including excessive carbon dioxide bubbles in the dialysate circuit and variable blood and dialysate flows. CONCLUSION. Treatment with the wearable artificial kidney was well tolerated and resulted in effective uremic solute clearance and maintenance of electrolyte and fluid homeostasis. These results serve as proof of concept that, after redesign to overcome observed technical problems, a wearable artificial kidney can be developed as a viable novel alternative dialysis technology. TRIAL REGISTRATION. ClinicalTrials.gov NCT02280005. FUNDING. The Wearable Artificial Kidney Foundation and Blood Purification Technologies Inc. PMID:27398407

  13. Unilateral spinal anesthesia using low-flow injection through a 29-gauge Quincke needle.

    PubMed

    Meyer, J; Enk, D; Penner, M

    1996-06-01

    Restriction of sympathetic denervation during spinal anesthesia may minimize hemodynamic alterations. Theoretically, the use of nonisobaric anesthetics may allow unilateral anesthesia and thus restrict sympathetic denervation to one side of the body. The present prospective study investigates the incidence of unilateral spinal anesthesia using hyperbaric bupivacaine 0.5% (1.4 mL, 1.6 mL, 1.8 mL, or 2.0 mL) injected via a 29-gauge Quincke needle with a pump-controlled injection flow of 1 mL/min. In 96 consecutive patients undergoing unilateral surgery of the lower extremities, spinal anesthesia was performed in the lateral decubitus position, which was maintained for 20 min postinjection. Increases in foot temperature of at least 0.5 degrees C were defined as sympathetic blockade. The incidence of unilateral block was not significantly influenced by the amount of bupivacaine. For all 96 patients, the incidence of unilateral sympathetic and complete motor block was 69% and 77%, respectively. Frequency of unilateral sensory block (assessed by pinprick and temperature discrimination) was significantly lower (28%). Strict unilateral spinal anesthesia was achieved in 24 cases (25%). Twenty minutes after injection of the local anesthetic, mean arterial blood pressure decreased significantly in patients with bilateral sympathetic blockade from 87 +/- 8 to 83 +/- 8 mm Hg (P < 0.01) but not in patients with unilateral sympathetic blockade (from 87 +/- 11 to 85 +/- 10 mm Hg). In conclusion, low-flow injection (1 mL/min) of hyperbaric bupivacaine 0.5% via a 29-gauge Quincke needle prevented bilateral sympathetic blockade in more than 69% of the patients. The data further suggest that loss of temperature discrimination alone is not a reliable estimation of sympathetic block.

  14. Therapeutic plasma exchange: a paired comparison of Fresenius AS104 vs. COBE Spectra.

    PubMed

    Burgstaler, E A; Pineda, A A

    2001-01-01

    For therapeutic plasma exchange (TPE), continuous flow separators are known to be efficient as exemplified by Fresenius AS104 and COBE Spectra. The AS104 uses an interface monitoring system in the centrifuge during TPE, whereas Spectra uses computer algorithms to establish the plasma-cell interface. To determine the plasma collection efficiency (PLCE), anticoagulant (AC) volumes used, and platelets (PLT) lost of the AS104 and the Spectra, we performed a prospective paired comparison of 20 TPE (each machine). The study included 17 patients, 1.3 plasma volume exchanges (without AC), equal inlet rates, and AC ratio of 13:1. Processing times did not include reinfuse mode. Platelet loss was determined by sampling the collection bags. Inlet rates were between 60-110 ml/min. Diagnosis included peripheral neuropathies, TTP and cryoglobulinemia. The AS104 had significantly (P<0.0001) lower average whole blood processed (F:6,601 vs. S:8,584 ml), AC volume (F:532 vs. S:719 ml), and processing time (F:80 vs. S:102 minutes) than Spectra. The AS104 had significantly (P<0.0001) higher average plasma flow rates (F:53 vs. S:44 ml/minute), plasma collection efficiency (F:90 vs. S:69%), and platelet loss (F:2.0 vs. S:0.14 x 10(11) plt) than Spectra. Platelet loss correlated with inlet flow rate with the AS104 but not with the Spectra. The AS104 has a significantly higher collection efficiency than Spectra allowing it to remove the same amount of plasma in significantly less time, by processing significantly less blood, using significantly less AC, but removing significantly more platelets than Spectra. Copyright 2001 Wiley-Liss, Inc.

  15. OpenCMISS: a multi-physics & multi-scale computational infrastructure for the VPH/Physiome project.

    PubMed

    Bradley, Chris; Bowery, Andy; Britten, Randall; Budelmann, Vincent; Camara, Oscar; Christie, Richard; Cookson, Andrew; Frangi, Alejandro F; Gamage, Thiranja Babarenda; Heidlauf, Thomas; Krittian, Sebastian; Ladd, David; Little, Caton; Mithraratne, Kumar; Nash, Martyn; Nickerson, David; Nielsen, Poul; Nordbø, Oyvind; Omholt, Stig; Pashaei, Ali; Paterson, David; Rajagopal, Vijayaraghavan; Reeve, Adam; Röhrle, Oliver; Safaei, Soroush; Sebastián, Rafael; Steghöfer, Martin; Wu, Tim; Yu, Ting; Zhang, Heye; Hunter, Peter

    2011-10-01

    The VPH/Physiome Project is developing the model encoding standards CellML (cellml.org) and FieldML (fieldml.org) as well as web-accessible model repositories based on these standards (models.physiome.org). Freely available open source computational modelling software is also being developed to solve the partial differential equations described by the models and to visualise results. The OpenCMISS code (opencmiss.org), described here, has been developed by the authors over the last six years to replace the CMISS code that has supported a number of organ system Physiome projects. OpenCMISS is designed to encompass multiple sets of physical equations and to link subcellular and tissue-level biophysical processes into organ-level processes. In the Heart Physiome project, for example, the large deformation mechanics of the myocardial wall need to be coupled to both ventricular flow and embedded coronary flow, and the reaction-diffusion equations that govern the propagation of electrical waves through myocardial tissue need to be coupled with equations that describe the ion channel currents that flow through the cardiac cell membranes. In this paper we discuss the design principles and distributed memory architecture behind the OpenCMISS code. We also discuss the design of the interfaces that link the sets of physical equations across common boundaries (such as fluid-structure coupling), or between spatial fields over the same domain (such as coupled electromechanics), and the concepts behind CellML and FieldML that are embodied in the OpenCMISS data structures. We show how all of these provide a flexible infrastructure for combining models developed across the VPH/Physiome community. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. CT perfusion imaging of the liver and the spleen in patients with cirrhosis: Is there a correlation between perfusion and portal venous hypertension?

    PubMed

    Talakić, Emina; Schaffellner, Silvia; Kniepeiss, Daniela; Mueller, Helmut; Stauber, Rudolf; Quehenberger, Franz; Schoellnast, Helmut

    2017-10-01

    To correlate hepatic and splenic CT perfusion parameters with hepatic venous pressure gradient (HVPG) measurements in patients with cirrhosis. Twenty-one patients with cirrhosis (males, 17; females, 4; mean ± SD age, 57 ± 7 years) underwent hepatic and splenic perfusion CT on a 320-detector row volume scanner as well as invasive measurement of HVPG. Different CT perfusion algorithms (maximum slope analysis and Patlak plot) were used to measure hepatic arterial flow (HAF), portal venous flow (PVF), hepatic perfusion index (HPI), splenic arterial flow (SAF), splenic blood volume (SBV) and splenic clearance (SCL). Hepatic and splenic perfusion parameters were correlated with HVPG, and sensitivity and specificity for detection of severe portal hypertension (≥12 mmHg) were calculated. The Spearman correlation coefficient was -0.53 (p < 0.05) between SAF and HVPG, and -0.68 (p < 0.01) between HVPG and SCL. Using a cut-off value of 125 ml/min/100 ml for SCL, sensitivity for detection of a HVPG of ≥12 mmHg was 94%, and specificity 100%. There was no significant correlation between hepatic perfusion parameters and HVPG. CT perfusion in patients with cirrhosis showed a strong correlation between SCL and HVPG and may be used for detection of severe portal hypertension. • SAF and SCL are statistically significantly correlated with HVPG • SCL showed stronger correlation with HVPG than SAF • 125 ml/min/100 ml SCL-cut-off yielded 94 % sensitivity, 100 % specificity for severe PH • HAF, PVF and HPI showed no statistically significant correlation with HVPG.

  17. Decreased Diastolic Ventricular Kinetic Energy in Young Patients with Fontan Circulation Demonstrated by Four-Dimensional Cardiac Magnetic Resonance Imaging.

    PubMed

    Sjöberg, Pia; Heiberg, Einar; Wingren, Pär; Ramgren Johansson, Jens; Malm, Torsten; Arheden, Håkan; Liuba, Petru; Carlsson, Marcus

    2017-04-01

    Four-dimensional (4D) flow magnetic resonance imaging (MRI) enables quantification of kinetic energy (KE) in intraventricular blood flow. This provides a novel way to understand the cardiovascular physiology of the Fontan circulation. In this study, we aimed to quantify the KE in functional single ventricles. 4D flow MRI was acquired in eleven patients with Fontan circulation (median age 12 years, range 3-29) and eight healthy volunteers (median age 26 years, range 23-36). Follow-up MRI after surgical or percutaneous intervention was performed in 3 patients. Intraventricular KE was calculated throughout the cardiac cycle and indexed to stroke volume (SV). The systolic/diastolic ratio of KE in Fontan patients was similar to the ratio of the controls' left ventricle (LV) or right ventricle (RV) depending on the patients' ventricular morphology (Cohen´s κ = 1.0). Peak systolic KE/SV did not differ in patients compared to the LV in controls (0.016 ± 0.006 mJ/ml vs 0.020 ± 0.004 mJ/ml, p = 0.09). Peak diastolic KE/SV in Fontan patients was lower than in the LV of the control group (0.028 ± 0.010 mJ/ml vs 0.057 ± 0.011 mJ/ml, p < 0.0001). The KE during diastole showed a plateau in patients with aortopulmonary collaterals. This is to our knowledge the first study that quantifies the intraventricular KE of Fontan patients. KE is dependent on the morphology of the ventricle, and diastolic KE indexed to SV in patients is decreased compared to controls. The lower KE in Fontan patients may be a result of impaired ventricular filling.

  18. Oslo government district bombing and Utøya island shooting July 22, 2011: The immediate prehospital emergency medical service response

    PubMed Central

    2012-01-01

    Background On July 22, 2011, a single perpetrator killed 77 people in a car bomb attack and a shooting spree incident in Norway. This article describes the emergency medical service (EMS) response elicited by the two incidents. Methods A retrospective and observational study was conducted based on data from the EMS systems involved and the public domain. The study was approved by the Data Protection Official and was defined as a quality improvement project. Results We describe the timeline and logistics of the EMS response, focusing on alarm, dispatch, initial response, triage and evacuation. The scenes in the Oslo government district and at Utøya island are described separately. Conclusions Many EMS units were activated and effectively used despite the occurrence of two geographically separate incidents within a short time frame. Important lessons were learned regarding triage and evacuation, patient flow and communication, the use of and need for emergency equipment and the coordination of helicopter EMS. PMID:22280935

  19. Anatomically-Aided PET Reconstruction Using the Kernel Method

    PubMed Central

    Hutchcroft, Will; Wang, Guobao; Chen, Kevin T.; Catana, Ciprian; Qi, Jinyi

    2016-01-01

    This paper extends the kernel method that was proposed previously for dynamic PET reconstruction, to incorporate anatomical side information into the PET reconstruction model. In contrast to existing methods that incorporate anatomical information using a penalized likelihood framework, the proposed method incorporates this information in the simpler maximum likelihood (ML) formulation and is amenable to ordered subsets. The new method also does not require any segmentation of the anatomical image to obtain edge information. We compare the kernel method with the Bowsher method for anatomically-aided PET image reconstruction through a simulated data set. Computer simulations demonstrate that the kernel method offers advantages over the Bowsher method in region of interest (ROI) quantification. Additionally the kernel method is applied to a 3D patient data set. The kernel method results in reduced noise at a matched contrast level compared with the conventional ML expectation maximization (EM) algorithm. PMID:27541810

  20. Simultaneous HPLC-F analysis of three recent antiepileptic drugs in human plasma.

    PubMed

    Mercolini, Laura; Mandrioli, Roberto; Amore, Mario; Raggi, Maria Augusta

    2010-09-21

    An original high-performance liquid chromatographic method with fluorescence detection is presented for the simultaneous determination of the three antiepileptic drugs gabapentin, vigabatrin and topiramate in human plasma. After pre-column derivatisation with dansyl chloride, the analytes were separated on a Hydro-RP column with a mobile phase composed of phosphate buffer (55%) and acetonitrile (45%) and detected at lambda(em)=500 nm, exciting at 300 nm. An original pre-treatment procedure on biological samples, based on solid-phase extraction with MCX cartridges for gabapentin and vigabatrin, and with Plexa cartridges for topiramate, gave high extraction yields (>91%), satisfactory precision (RSD<6.4%) and good selectivity. Linearity was found in the 0.2-50.0 microg mL(-1) range for gabapentin, in the 1.0-100.0 microg mL(-1) range for vigabatrin and in the 1.0-50.0 microg mL(-1) range for topiramate, with limits of detection (LODs) between 0.1 and 0.3 microg mL(-1). After validation, the method was successfully applied to some plasma samples from patients undergoing therapy with one or more of these drugs. Accuracy results were satisfactory (recovery >91%). Therefore, the method seems to be suitable for the therapeutic drug monitoring (TDM) of patients treated with gabapentin, vigabatrin and topiramate. Copyright 2010 Elsevier B.V. All rights reserved.

  1. Elimination of oral candidiasis may increase stimulated whole salivary flow rate.

    PubMed

    Ohga, Noritaka; Yamazaki, Yutaka; Sato, Jun; Asaka, Takuya; Morimoto, Masahiro; Hata, Hironobu; Satoh, Chiharu; Kitagawa, Yoshimasa

    2016-11-01

    Candida infections are frequently encountered fungal infections in the oral mucosa. This study aimed to evaluate the effect of eliminating Candida spp. on stimulated whole salivary flow rate (SWS) in patients with oral candidiasis. This study involved 66 patients with oral candidiasis. Fifty-two consecutive patients, successfully treated by antifungal therapy, were available to examine the effect of elimination of oral Candida spp. on SWS (success group); the 14 patients who tested positive for Candida after therapy were retrospectively included (control group). SWS were used to measure saliva production. Moreover, tongue pain and xerostomia were evaluated using visual analog score (VAS). By eliminating oral Candida spp., SWS significantly increased in the success group after antifungal therapy [SWS: mean value 0.89±0.51ml/min (median 0.82ml/min: 0.15-2.14) to mean value 1.16±0.58ml/min (median 1.05ml/min: 0.2-2.93), P<0.001]. Furthermore, VAS scores for subjective tongue pain and xerostomia were significantly decreased compared with those before therapy in the success group [xerostomia: mean value 52.5±28.8 (median 53: 9-100) to 24.2±1.6 (median 17: 0-70), tongue pain: mean value 52.6±27.2 (median 56: 1-93) to 15.3±18.0 (median 9: 0-62). P<0.001]. There was no significant difference in SWS, subjective tongue pain, or xerostomia in the control group after antifungal therapy. [SWS: mean value 1.08±0.83ml/min (median 0.69ml/min: 0.2-2.7) to 0.98±0.59ml/min (median 0.8ml/min: 0.45-2.5), P=0.65], [xerostomia: mean value 62.8±5.3 (median 62: 28-70) to 64.0±8.8 (median 64: 56-73), P=0.58, tongue pain: mean value 64.3±18.6 (median 67: 31-87) to 58.4±20.0 (median 8: 20-78), respectively; P=0.24] CONCLUSION: Our study demonstrated that SWS may increase by eliminating oral Candida spp. in patients with oral candidiasis. Copyright © 2016. Published by Elsevier Ltd.

  2. Evaluation of blood flow in human exercising muscle by diffuse correlation spectroscopy: a phantom model study

    NASA Astrophysics Data System (ADS)

    Nakabayashi, Mikie; Ono, Yumie; Ichinose, Masashi

    2018-02-01

    Diffuse correlation spectroscopy (DCS) has a potential to noninvasively and quantitatively measure the blood flow in the exercising muscle that could contribute to the fields of sports physiology and medicine. However, the blood flow index (BFI) measured from skin surface by DCS reflects hemodynamic signals from both superficial tissue and muscle layer. Thus, an appropriate calibration technology is required to quantify the absolute blood flow in the muscle layer. We therefore fabricated a realistic two-layer phantom model consisted of a static silicon layer imitating superficial tissue and a dynamic flow layer imitating the muscle blood flow and investigated the relationship between the simulated blood flow rate in the muscle layer and the BFI measured from the surface of the phantom. The absorption coefficient and the reduced scattering coefficient of the forearm were measured from 25 healthy young adults using a time-resolved nearinfrared spectroscopy. The depths of the superficial and muscle layers of forearm were also determined by ultrasound tomography images from 25 healthy young adults. The phantoms were fabricated to satisfy these optical coefficients and anatomical constraints. The simulated blood flow rate were set from 0 mL/ min to 68.7 mL/ min in ten steps, which is considered to cover a physiological range of mean blood flow of the forearm between per 100g of muscle tissue at rest to heavy dynamic handgrip exercise. We found a proportional relationship between the flow rates and BFIs with significant correlation coefficient of R = 0.986. Our results suggest that the absolute exercising muscle blood flow could be estimated by DCS with optimal calibration using phantom models.

  3. Effect of gravitational sedimentation on simulated aerosol dispersion in the human acinus.

    PubMed

    Darquenne, Chantal; Prisk, G Kim

    2003-04-01

    We studied the effect of gravitational sedimentation on the dispersion of 0.5 and 1 micrometer-diameter particle boluses within a two-dimensional symmetric six-generation model of the human acinus. Boluses were introduced at the beginning of a 2-s inspiration immediately followed by a 4-s expiration, in normal gravity (1 G) and in the absence of gravity (0 G). The flow corresponded to a flow rate at the mouth of 500 ml/s. In 0 G, simulated dispersion (Hsim) was 16 ml for both particle sizes. In 1 G, Hsim was 71 and 242 ml for 0.5 and 1 micrometer-diameter particles, respectively, showing the effect of gravitational sedimentation. The difference between experimental data (J. Appl. Physiol. 86 (1999) 1402) and simulations was independent of particle size. This suggests that the residual dispersion was independent of the intrinsic properties of the particles and was more likely due to other mechanisms such as ventilation inhomogeneities, cardiogenic oscillations and alveolar wall motion. c2003 Elsevier Science Ltd. All rights reserved.

  4. Effect of gravitational sedimentation on simulated aerosol dispersion in the human acinus

    NASA Technical Reports Server (NTRS)

    Darquenne, Chantal; Prisk, G. Kim

    2003-01-01

    We studied the effect of gravitational sedimentation on the dispersion of 0.5 and 1 micrometer-diameter particle boluses within a two-dimensional symmetric six-generation model of the human acinus. Boluses were introduced at the beginning of a 2-s inspiration immediately followed by a 4-s expiration, in normal gravity (1 G) and in the absence of gravity (0 G). The flow corresponded to a flow rate at the mouth of 500 ml/s. In 0 G, simulated dispersion (Hsim) was 16 ml for both particle sizes. In 1 G, Hsim was 71 and 242 ml for 0.5 and 1 micrometer-diameter particles, respectively, showing the effect of gravitational sedimentation. The difference between experimental data (J. Appl. Physiol. 86 (1999) 1402) and simulations was independent of particle size. This suggests that the residual dispersion was independent of the intrinsic properties of the particles and was more likely due to other mechanisms such as ventilation inhomogeneities, cardiogenic oscillations and alveolar wall motion. c2003 Elsevier Science Ltd. All rights reserved.

  5. Blood flow of the right and left submandibular gland during unilateral carotid artery occlusion in rat: role of nitric oxide.

    PubMed

    Vág, J; Hably, C; Fazekas, A; Bartha, J

    1999-01-01

    The aim of the present study was to investigate the effect of unilateral carotid artery occlusion on the blood flow of submandibular gland in anesthetized rats and identify the role of nitric oxide (NO) in blood flow changes after the artery occlusion. L-NAME (N omega-nitro-L-arginine-methyl-ester; 10 mg/kg/day, per os) dissolved in tap water was used to block nitric oxide synthase. Glandular blood flow was measured using Sapirstein's indicator (86Rb) distribution technique. In the control animals the blood flow of left (ligated side) submandibular gland was lower than in the right (unligated side) one (right: 76.4+/-15.4 ml/min/100 g, 64.1+/-13.4 ml/min/100 g, p<0.01). The blood flow of submandibular glands decreased in NOS blocked group versus control. The vascular resistance after L-NAME treatment was elevated (control: 11+/-2.3 R/kg, L-NAME: 17.5+/-4.1 R/kg, p<0.001). In L-NAME group the difference between blood flow value of the left and right submandibular gland was significantly lower than in the control group (control: -16%, NAME: -8%, p<0.01). The maintenance of the blood flow in the left submandibular gland during ligation of the left common carotid artery could be due to the good vascular anastomotic system at these regions and adaptation of the submandibular vessels to the decreased perfusion pressure. Nitric oxide may have a role in the regulation of blood flow tinder this condition.

  6. Quantitative passive soil vapor sampling for VOCs--Part 4: Flow-through cell.

    PubMed

    McAlary, Todd; Groenevelt, Hester; Seethapathy, Suresh; Sacco, Paolo; Crump, Derrick; Tuday, Michael; Schumacher, Brian; Hayes, Heidi; Johnson, Paul; Parker, Louise; Górecki, Tadeusz

    2014-05-01

    This paper presents a controlled experiment comparing several quantitative passive samplers for monitoring concentrations of volatile organic compound (VOC) vapors in soil gas using a flow-through cell. This application is simpler than conventional active sampling using adsorptive tubes because the flow rate does not need to be precisely measured and controlled, which is advantageous because the permeability of subsurface materials affects the flow rate and the permeability of geologic materials is highly variable. Using passive samplers in a flow-through cell, the flow rate may not need to be known exactly, as long as it is sufficient to purge the cell in a reasonable time and minimize any negative bias attributable to the starvation effect. An experiment was performed in a 500 mL flow-through cell using a two-factor, one-half fraction fractional factorial test design with flow rates of 80, 670 and 930 mL min(-1) and sample durations of 10, 15 and 20 minutes for each of five different passive samplers (passive Automatic Thermal Desorption Tube, Radiello®, SKC Ultra, Waterloo Membrane Sampler™ and 3M™ OVM 3500). A Summa canister was collected coincident with each passive sampler and analyzed by EPA Method TO-15 to provide a baseline for comparison of the passive sampler concentrations. The passive sampler concentrations were within a factor of 2 of the Summa canister concentrations in 32 of 35 cases. Passive samples collected at the low flow rate and short duration showed low concentrations, which is likely attributable to insufficient purging of the cell after sampler placement.

  7. A Novel Imaging Method for the Cartilaginous Eustachian Tube Lumen: Computerized Tomography During the Forced Response Test.

    PubMed

    Alper, Cuneyt M; Rath, Tanya J; Teixeira, Miriam S; Swarts, J Douglas

    2018-01-01

    In vivo imaging of the open cartilaginous Eustachian tube (ET) lumen by computed tomography (CT) scan during ET function (ETF) testing to establish new methodology. Five adults underwent unilateral ETF testing of an ear with a nonintact tympanic membrane using the forced response test (FRT) to measure the opening pressure (PO), steady state pressure (PS), and flow conductance (CS). Then at baseline and during the PS phase of the FRT, a temporal-bone CT scan with continuous 0.625 mm thickness was obtained. Multiplanar oblique reformats along the axis of the ET were created, and point value and region of interest (ROI) Hounsfield unit measurements were recorded from the location of the ET lumen. At the FRT flow rate of 11 ml/min, the average PO, PS, and CS were 370.5 daPa, 119.6 daPa, and 0.16 ml/min/daPa, respectively. For flow rates of 23 and 46 ml/min, these values were 236.2, 204.2, 0.12 and 385.5, 321.1, 0.18, respectively. Although areas with lower attenuation were suggestive of air density, a distinct air-filled cartilaginous ET lumen could not be confirmed. While the current imaging parameters failed to resolve the air-soft tissue interface throughout the open cartilaginous ET, further advances in imaging may obviate this limitation.

  8. Preliminary Diffusive Clearance of Silicon Nanopore Membranes in a Parallel Plate Configuration for Renal Replacement Therapy

    PubMed Central

    Kim, Steven; Heller, James; Iqbal, Zohora; Kant, Rishi; Kim, Eun Jung; Durack, Jeremy; Saeed, Maythem; Do, Loi; Hetts, Steven; Wilson, Mark; Brakeman, Paul; Fissell, William H.; Roy, Shuvo

    2015-01-01

    Silicon nanopore membranes (SNM) with compact geometry and uniform pore size distribution have demonstrated a remarkable capacity for hemofiltration. These advantages could potentially be used for hemodialysis. Here we present an initial evaluation of the SNM’s mechanical robustness, diffusive clearance, and hemocompatibility in a parallel plate configuration. Mechanical robustness of the SNM was demonstrated by exposing membranes to high flows (200ml/min) and pressures (1,448mmHg). Diffusive clearance was performed in an albumin solution and whole blood with blood and dialysate flow rates of 25ml/min. Hemocompatibility was evaluated using scanning electron microscopy and immunohistochemistry after 4-hours in an extra-corporeal porcine model. The pressure drop across the flow cell was 4.6mmHg at 200ml/min. Mechanical testing showed that SNM could withstand up to 775.7mmHg without fracture. Urea clearance did not show an appreciable decline in blood versus albumin solution. Extra-corporeal studies showed blood was successfully driven via the arterial-venous pressure differential without thrombus formation. Bare silicon showed increased cell adhesion with a 4.1 fold increase and 1.8 fold increase over polyethylene-glycol (PEG)-coated surfaces for tissue plasminogen factor (t-PA) and platelet adhesion (CD-41), respectively. These initial results warrant further design and development of a fully scaled SNM-based parallel plate dialyzer for renal replacement therapy. PMID:26692401

  9. Quantitative measurement of cerebral blood flow during hypothermia with a time-resolved near-infrared technique

    NASA Astrophysics Data System (ADS)

    Fazel Bakhsheshi, Mohammad; Diop, Mamadou; St Lawrence, Keith; Lee, Ting-Yim

    2012-02-01

    Hypothermia, in which the brain is cooled to 32-33 °C, has been shown to be neuroprotective for brain injury caused by hypoxia-ischemia, head trauma, or neonatal asphyxia. Neuroprotective effect of Hypothermia is partly due to suppression of brain metabolism and cerebral blood flow (CBF). The ability to measure CBF at the bedside provides a means of detecting, and thereby preventing, secondary ischemia during neuro intensive care before brain injury occurs. The purpose of the present study is to investigate the ability of a time-resolved near-infrared (TR-NIR) bolus-tracking method using indocyanine green as an intravascular flow tracer to measure CBF during cooling in a newborn animal model. For validation, CBF was independently measured by computed tomography (CT) perfusion. The results show a good agreement between CBF obtained with the two methods (R2 ~ 0.84, Δ ~ 5.84 ml. min -1.100 g -1, 32-38.5 °C), demonstrating the ability of the TR-NIR technique to non-invasively measure absolute CBF in-vivo during dynamic hypothermia. The TR-NIR technique reveals that CBF decreases from 54.3 +/- 5.4 ml. min -1.100 g -1, at normothermia (Tbrain of 38.5 °C), to 33.8 +/- 0.9 ml. min -1.100 g -1 at Tbrain of 32 °C during the hypothermia treatment.

  10. Early Evidence of Sepsis-Associated Hyperperfusion-A Study of Cerebral Blood Flow Measured With MRI Arterial Spin Labeling in Critically Ill Septic Patients and Control Subjects.

    PubMed

    Masse, Marie-Hélène; Richard, Marie Anne; D'Aragon, Frédérick; St-Arnaud, Charles; Mayette, Michael; Adhikari, Neill K J; Fraser, William; Carpentier, André; Palanchuck, Steven; Gauthier, David; Lanthier, Luc; Touchette, Matthieu; Lamontagne, Albert; Chénard, Jean; Mehta, Sangeeta; Sansoucy, Yanick; Croteau, Etienne; Lepage, Martin; Lamontagne, François

    2018-04-06

    Mechanisms underlying sepsis-associated encephalopathy remain unclear, but reduced cerebral blood flow, alone or in conjunction with altered autoregulation, is reported as a potential contributor. We compared cerebral blood flow of control subjects and vasopressor-dependent septic patients. Randomized crossover study. MRI with arterial spin labeling. Ten sedated septic patients on mechanical ventilation (four with controlled chronic hypertension) and 12 control subjects (six with controlled chronic hypertension) were enrolled. Mean ± SD ages were 61.4 ± 10.2 and 44.2 ± 12.8 years, respectively (p = 0.003). Mean Acute Physiology and Chronic Health Evaluation II score of septic patients at ICU admission was 27.7 ± 6.6. To assess the potential confounding effects of sedation and mean arterial pressure, we measured cerebral blood flow with and without sedation with propofol in control subjects and at a target mean arterial pressure of 65 mm Hg and greater than or equal to 75 mm Hg in septic patients. The sequence of sedation versus no sedation and mean arterial pressure targets were randomized. In septic patients, cerebral blood flow measured at a mean arterial pressure target of 65 mm Hg (40.4 ± 10.9 mL/100 g/min) was not different from cerebral blood flow measured at a mean arterial pressure target of greater than or equal to 75 mm Hg (41.3 ± 9.8 mL/100 g/min; p = 0.65). In control subjects, we observed no difference in cerebral blood flow measured without and with sedation (24.8 ± 4.2 vs 24.9 ± 5.9 mL/100 g/min; p = 0.93). We found no interaction between chronic hypertension and the effect of sedation or mean arterial pressure targets. Cerebral blood flow measured in sedated septic patients (mean arterial pressure target 65 mm Hg) was 62% higher than in sedated control subjects (p = 0.001). In septic patients, cerebral blood flow was higher than in sedated control subjects and did not vary with mean arterial pressure targets. Further research is required to understand the clinical significance of cerebral hyperperfusion in septic patients on vasopressors and to reassess the neurologic effects of current mean arterial pressure targets in sepsis.

  11. Ascorbate elevates perfusion pressure in the bovine extraocular long posterior ciliary artery: role of endothelium-derived hyperpolarizing factor (EDHF).

    PubMed

    Stirrat, Alison; Nelli, Silvia; McGuckin, Alicia; Ho, Vivian Wing Man; Wilson, William S; Martin, William

    2006-03-18

    Ascorbate blocks agonist-induced, endothelium-derived hyperpolarizing factor (EDHF)-mediated vasodilatation in the bovine perfused ciliary artery and this is associated with a rise in perfusion pressure. We now report the origins of this ascorbate-induced rise in perfusion pressure. In segments of ciliary artery perfused at 2.5 ml/min, the addition of ascorbate (10-150 microM) enhanced U46619-induced perfusion pressure. Ascorbate produced no enhancement in the absence of U46619, suggesting that its effects resulted not from a constrictor action but through removal of a tonic vasodilator influence. Experiments revealed the endothelial source of this vasodilator influence, and EDHF, but not nitric oxide or prostanoids, appeared to be involved. The ascorbate-induced enhancement of vasoconstrictor tone was not seen in a static myograph or in segments perfused at low rates of flow, but was seen at flow rates of 2.5 ml(-1) and above. We conclude that ascorbate augments vasoconstrictor tone through inhibition of flow-induced EDHF activity.

  12. Simple and clean determination of tetracyclines by flow injection analysis

    NASA Astrophysics Data System (ADS)

    Rodríguez, Michael Pérez; Pezza, Helena Redigolo; Pezza, Leonardo

    2016-01-01

    An environmentally reliable analytical methodology was developed for direct quantification of tetracycline (TC) and oxytetracycline (OTC) using continuous flow injection analysis with spectrophotometric detection. The method is based on the diazo coupling reaction between the tetracyclines and diazotized sulfanilic acid in a basic medium, resulting in the formation of an intense orange azo compound that presents maximum absorption at 434 nm. Experimental design was used to optimize the analytical conditions. The proposed technique was validated over the concentration range of 1 to 40 μg mL- 1, and was successfully applied to samples of commercial veterinary pharmaceuticals. The detection (LOD) and quantification (LOQ) limits were 0.40 and 1.35 μg mL- 1, respectively. The samples were also analyzed by an HPLC method, and the results showed agreement with the proposed technique. The new flow injection method can be immediately used for quality control purposes in the pharmaceutical industry, facilitating monitoring in real time during the production processes of tetracycline formulations for veterinary use.

  13. Primary standards for measuring flow rates from 100 nl/min to 1 ml/min - gravimetric principle.

    PubMed

    Bissig, Hugo; Petter, Harm Tido; Lucas, Peter; Batista, Elsa; Filipe, Eduarda; Almeida, Nelson; Ribeiro, Luis Filipe; Gala, João; Martins, Rui; Savanier, Benoit; Ogheard, Florestan; Niemann, Anders Koustrup; Lötters, Joost; Sparreboom, Wouter

    2015-08-01

    Microflow and nanoflow rate calibrations are important in several applications such as liquid chromatography, (scaled-down) process technology, and special health-care applications. However, traceability in the microflow and nanoflow range does not go below 16 μl/min in Europe. Furthermore, the European metrology organization EURAMET did not yet validate this traceability by means of an intercomparison between different National Metrology Institutes (NMIs). The NMIs METAS, Centre Technique des Industries Aérauliques et Thermiques, IPQ, Danish Technological Institute, and VSL have therefore developed and validated primary standards to cover the flow rate range from 0.1 μl/min to at least 1 ml/min. In this article, we describe the different designs and methods of the primary standards of the gravimetric principle and the results obtained at the intercomparison for the upper flow rate range for the various NMIs and Bronkhorst High-Tech, the manufacturer of the transfer standards used.

  14. ISAC's Gating-ML 2.0 data exchange standard for gating description.

    PubMed

    Spidlen, Josef; Moore, Wayne; Brinkman, Ryan R

    2015-07-01

    The lack of software interoperability with respect to gating has traditionally been a bottleneck preventing the use of multiple analytical tools and reproducibility of flow cytometry data analysis by independent parties. To address this issue, ISAC developed Gating-ML, a computer file format to encode and interchange gates. Gating-ML 1.5 was adopted and published as an ISAC Candidate Recommendation in 2008. Feedback during the probationary period from implementors, including major commercial software companies, instrument vendors, and the wider community, has led to a streamlined Gating-ML 2.0. Gating-ML has been significantly simplified and therefore easier to support by software tools. To aid developers, free, open source reference implementations, compliance tests, and detailed examples are provided to stimulate further commercial adoption. ISAC has approved Gating-ML as a standard ready for deployment in the public domain and encourages its support within the community as it is at a mature stage of development having undergone extensive review and testing, under both theoretical and practical conditions. © 2015 International Society for Advancement of Cytometry.

  15. A new statistical methodology predicting chip failure probability considering electromigration

    NASA Astrophysics Data System (ADS)

    Sun, Ted

    In this research thesis, we present a new approach to analyze chip reliability subject to electromigration (EM) whose fundamental causes and EM phenomenon happened in different materials are presented in this thesis. This new approach utilizes the statistical nature of EM failure in order to assess overall EM risk. It includes within-die temperature variations from the chip's temperature map extracted by an Electronic Design Automation (EDA) tool to estimate the failure probability of a design. Both the power estimation and thermal analysis are performed in the EDA flow. We first used the traditional EM approach to analyze the design with a single temperature across the entire chip that involves 6 metal and 5 via layers. Next, we used the same traditional approach but with a realistic temperature map. The traditional EM analysis approach and that coupled with a temperature map and the comparison between the results of considering and not considering temperature map are presented in in this research. A comparison between these two results confirms that using a temperature map yields a less pessimistic estimation of the chip's EM risk. Finally, we employed the statistical methodology we developed considering a temperature map and different use-condition voltages and frequencies to estimate the overall failure probability of the chip. The statistical model established considers the scaling work with the usage of traditional Black equation and four major conditions. The statistical result comparisons are within our expectations. The results of this statistical analysis confirm that the chip level failure probability is higher i) at higher use-condition frequencies for all use-condition voltages, and ii) when a single temperature instead of a temperature map across the chip is considered. In this thesis, I start with an overall review on current design types, common flows, and necessary verifications and reliability checking steps used in this IC design industry. Furthermore, the important concepts about "Scripting Automation" which is used in all the integration of using diversified EDA tools in this research work are also described in detail with several examples and my completed coding works are also put in the appendix for your reference. Hopefully, this construction of my thesis will give readers a thorough understanding about my research work from the automation of EDA tools to the statistical data generation, from the nature of EM to the statistical model construction, and the comparisons among the traditional EM analysis and the statistical EM analysis approaches.

  16. Does Peak Urine Flow Rate Predict the Development of Incident Lower Urinary Tract Symptoms in Men with Mild to No Current Symptoms? Results from REDUCE.

    PubMed

    Simon, Ross M; Howard, Lauren E; Moreira, Daniel M; Roehrborn, Claus; Vidal, Adriana; Castro-Santamaria, Ramiro; Freedland, Stephen J

    2017-09-01

    We determined whether decreased peak urine flow is associated with future incident lower urinary tract symptoms in men with mild to no lower urinary tract symptoms. Our population consisted of 3,140 men from the REDUCE (Reduction by Dutasteride of Prostate Cancer Events) trial with mild to no lower urinary tract symptoms, defined as I-PSS (International Prostate Symptom Score) less than 8. REDUCE was a randomized trial of dutasteride vs placebo for prostate cancer prevention in men with elevated prostate specific antigen and negative biopsy. I-PSS measures were obtained every 6 months throughout the 4-year study. The association between peak urine flow rate and progression to incident lower urinary tract symptoms, defined as the first of medical treatment, surgery or sustained and clinically significant lower urinary tract symptoms, was tested by multivariable Cox models, adjusting for various baseline characteristics and treatment arm. On multivariable analysis as a continuous variable, decreased peak urine flow rate was significantly associated with an increased risk of incident lower urinary tract symptoms (p = 0.002). Results were similar in the dutasteride and placebo arms. On univariable analysis when peak flow was categorized as 15 or greater, 10 to 14.9 and less than 10 ml per second, flow rates of 10 to 14.9 and less than 10 ml per second were associated with a significantly increased risk of incident lower urinary tract symptoms (HR 1.39, p = 0.011 and 1.67, p <0.001, respectively). Results were similar on multivariable analysis, although in the 10 to 14.9 ml per second group findings were no longer statistically significant (HR 1.26, p = 0.071). In men with mild to no lower urinary tract symptoms a decreased peak urine flow rate is independently associated with incident lower urinary tract symptoms. If confirmed, these men should be followed closer for incident lower urinary tract symptoms. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  17. Mesenteric blood flow, glucose absorption and blood pressure responses to small intestinal glucose in critically ill patients older than 65 years.

    PubMed

    Sim, Jennifer A; Horowitz, M; Summers, M J; Trahair, L G; Goud, R S; Zaknic, A V; Hausken, T; Fraser, J D; Chapman, M J; Jones, K L; Deane, A M

    2013-02-01

    To compare nutrient-stimulated changes in superior mesenteric artery (SMA) blood flow, glucose absorption and glycaemia in individuals older than 65 years with, and without, critical illness. Following a 1-h 'observation' period (t (0)-t (60)), 0.9 % saline and glucose (1 kcal/ml) were infused directly into the small intestine at 2 ml/min between t (60)-t (120), and t (120)-t (180), respectively. SMA blood flow was measured using Doppler ultrasonography at t (60) (fasting), t (90) and t (150) and is presented as raw values and nutrient-stimulated increment from baseline (Δ). Glucose absorption was evaluated using serum 3-O-methylglucose (3-OMG) concentrations during, and for 1 h after, the glucose infusion (i.e. t (120)-t (180) and t (120)-t (240)). Mean arterial pressure was recorded between t (60)-t (240). Data are presented as median (25th, 75th percentile). Eleven mechanically ventilated critically ill patients [age 75 (69, 79) years] and nine healthy volunteers [70 (68, 77) years] were studied. The magnitude of the nutrient-stimulated increase in SMA flow was markedly less in the critically ill when compared with healthy subjects [Δt (150): patients 115 (-138, 367) versus health 836 (618, 1,054) ml/min; P = 0.001]. In patients, glucose absorption was reduced during, and for 1 h after, the glucose infusion when compared with health [AUC(120-180): 4.571 (2.591, 6.551) versus 11.307 (8.447, 14.167) mmol/l min; P < 0.001 and AUC(120-240): 26.5 (17.7, 35.3) versus 40.6 (31.7, 49.4) mmol/l min; P = 0.031]. A close relationship between the nutrient-stimulated increment in SMA flow and glucose absorption was evident (3-OMG AUC(120-180) and ∆SMA flow at t (150): r (2) = 0.29; P < 0.05). In critically ill patients aged >65 years, stimulation of SMA flow by small intestinal glucose infusion may be attenuated, which could account for the reduction in glucose absorption.

  18. Accuracy of right and left ventricular functional assessment by short-axis vs axial cine steady-state free-precession magnetic resonance imaging: intrapatient correlation with main pulmonary artery and ascending aorta phase-contrast flow measurements.

    PubMed

    James, Susan H; Wald, Rachel; Wintersperger, Bernd J; Jimenez-Juan, Laura; Deva, Djeven; Crean, Andrew M; Nguyen, Elsie; Paul, Narinder S; Ley, Sebastian

    2013-08-01

    The left ventricle (LV) is routinely assessed with cardiac magnetic resonance imaging (MRI) by using short-axis orientation; it remains unclear whether the right ventricle (RV) can also be adequately assessed in this orientation or whether dedicated axial orientation is required. We used phase-contrast (PC) flow measurements in the main pulmonary artery (MPA) and the ascending aorta (Aorta) as nonvolumetric standard of reference and compared RV and LV volumes in short-axis and axial orientations. A retrospective analysis identified 30 patients with cardiac MRI data sets. Patients underwent MRI (1.5 T or 3 T), with retrospectively gated cine steady-state free-precession in axial and short-axis orientations. PC flow analyses of MPA and Aorta were used as the reference measure of RV and LV output. There was a high linear correlation between MPA-PC flow and RV-stroke volume (SV) short axis (r = 0.9) and RV-SV axial (r = 0.9). Bland-Altman analysis revealed a mean offset of 1.4 mL for RV axial and -2.3 mL for RV-short-axis vs MPA-PC flow. There was a high linear correlation between Aorta-PC flow and LV-SV short-axis (r = 0.9) and LV-SV axial (r = 0.9). Bland-Altman analysis revealed a mean offset of 4.8 m for LV short axis and 7.0 mL for LV axial vs Aorta-PC flow. There was no significant difference (P = .6) between short-axis-LV SV and short-axis-RV SV. No significant impact of the slice acquisition orientation for determination of RV and LV stroke volumes was found. Therefore, cardiac magnetic resonance workflow does not need to be extended by an axial data set for patients without complex cardiac disease for assessment of biventricular function and volumes. Copyright © 2013 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  19. In vitro performance testing of a pediatric oxygenator with an integrated pulsatile pump.

    PubMed

    Borchardt, Ralf; Schlanstein, Peter; Mager, Ilona; Arens, Jutta; Schmitz-Rode, Thomas; Steinseifer, Ulrich

    2012-01-01

    For different lung and heart diseases (e.g., acute respiratory distress syndrome, congenital heart failure, and cardiomyopathy) extracorporeal membrane oxygenation is a well-established therapy, particularly in the field of neonatal and pediatric medicine. To reduce the priming volume of the extracorporeal circuit, different components can be combined. In this study, an oval-shaped oxygenator (called ExMeTrA) with integrated pulsatile pump was tested in vitro using porcine blood. A feasibility study regarding the performance of collapsing and expanding silicone tubes within an oxygenator fiber bundle as a pulsatile pump was previously completed with successful results. The findings of this study improve upon the previous feasibility results, particularly in terms of gas exchange and filling volume. Five modules were manufactured in sizes of 20 ± 2.2 ml (priming volume) with fiber surface areas of 0.24 ± 0.027 m(2) and an analytically calculated volume pumping capacity of 692 ± 75 ml/min. The modules were made of polymethylpentene fibers with dense outer layer to permit long-term applications. The gas exchange rates at a gas/blood flow ratio of 2:1 were between 64 and 72.7 ml(O)(2)/l(blood) and between 62.5 and 81.5 ml/l(blood), depending on the blood flow. The individual module's pumping capacity ranged from 200-500 ml/min thus providing room for further improvements. In order to enhance the pumping capacity while maintaining sufficient gas exchange rates future optimization, adjustments will be made to the inlet and outlet geometries.

  20. Laser prostatectomy using a right angle delivery system

    NASA Astrophysics Data System (ADS)

    Rocha, Flavio T.; Mitre, Anuar I.; Chavantes, Maria C.; Arap, Sami

    1995-05-01

    Benign prostate hyperplasia (BPH) represents a major health problem in old men. In the present transurethral resection of the prostate (TURP) is the gold standard treatment for BPH. Although TURP is related to low mortality rates its mobidity is quite high. To evaluate the efficacy and safety of a new surgical treatment for BPH we undertook 30 patients with symptomatic BPH. All of them were submitted to a laser prostatectomy using a lateral delivery system (non contact) connected to a Nd-YAG laser font. The preoperative evaluation showed a prostate weight ranging from 30,5 to 86 grams (mean equals 42,5). The preoperative prostatic specific antigen (PSA) ranged from 0,9 to 10,2 ng/dl (mean equals 4.3). The International prostate symptom score (I-PSS) ranged from 16 to 35 points (means equals 23,58). The flow rate ranged from 0 to m 12.8 ml/sec (mean equals 4,65) and the postvoid residual urine from 20 to 400 ml (mean equals 100). We obtained follow-up in 20 patients. After three months after the procedure the parameters were: I-PSS from 4 to 20 points (mean equals 7,0) p < 0.05. Flow rate from 6,5 to m 19.4 ml/sec (mean equals 12,95) p < 0.05 and the postvoid residual urine from 17 to 70 ml (mean equals 30 ml) p < 0.05. No blood transfusion was required. The complications were persistent disuria in two patients, bladder neck contracture in one patient and urethral stenosis in one patient. We concluded that laser prostatectomy is a safe and effective treatment for BPH.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Visualization of blood flow in a cerebral aneurysm. Streamlines (colored by fluid velocity magnitude) reveal the complexity of the flow, isocontours of vorticity show blood vortex structures (colored by pressure), and the flexible arterial wall is colored by the stress magnitude, where regions in red indicate areas of high stress. Credits: Science: Paris Perdikaris, Yue Yu, George Em. Karniadakis and Leopold Grinberg Visualization: Joseph A. Insley and Michael E. Papka

  2. Cellulase production in a new mutant strain of Penicillium decumbens ML-017 by solid state fermentation with rice bran.

    PubMed

    Liu, Yun-Tao; Luo, Ze-Yu; Long, Chuan-Nan; Wang, Hai-Dong; Long, Min-Nan; Hu, Zhong

    2011-10-01

    To produce cellulolytic enzyme efficiently, Penicillium decumbens strain L-06 was used to prepare mutants with ethyl methane sulfonate (EMS) and UV-irradiation. A mutant strain ML-017 is shown to have a higher cellulase activity than others. Box-Behnken's design (BBD) and response surface methodology (RSM) were adopted to optimize the conditions of cellulase (filter paper activity, FPA) production in strain ML-017 by solid-state fermentation (SSF) with rice bran as the substrate. And the result shows that the initial pH, moisture content and culture temperature all have significant effect on the production of cellulase. The optimized condition shall be initial pH 5.7, moisture content 72% and culture temperature 30°C. The maximum cellulase (FPA) production was obtained under the optimized condition, which is 5.76 IU g(-1), increased by 44.12% to its original strain. It corresponded well with the calculated results (5.15 IU g(-1)) by model prediction. The result shows that both BBD and RSM are the cellulase optimization methods with good prospects. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. A radial flow microfluidic device for ultra-high-throughput affinity-based isolation of circulating tumor cells.

    PubMed

    Murlidhar, Vasudha; Zeinali, Mina; Grabauskiene, Svetlana; Ghannad-Rezaie, Mostafa; Wicha, Max S; Simeone, Diane M; Ramnath, Nithya; Reddy, Rishindra M; Nagrath, Sunitha

    2014-12-10

    Circulating tumor cells (CTCs) are believed to play an important role in metastasis, a process responsible for the majority of cancer-related deaths. But their rarity in the bloodstream makes microfluidic isolation complex and time-consuming. Additionally the low processing speeds can be a hindrance to obtaining higher yields of CTCs, limiting their potential use as biomarkers for early diagnosis. Here, a high throughput microfluidic technology, the OncoBean Chip, is reported. It employs radial flow that introduces a varying shear profile across the device, enabling efficient cell capture by affinity at high flow rates. The recovery from whole blood is validated with cancer cell lines H1650 and MCF7, achieving a mean efficiency >80% at a throughput of 10 mL h(-1) in contrast to a flow rate of 1 mL h(-1) standardly reported with other microfluidic devices. Cells are recovered with a viability rate of 93% at these high speeds, increasing the ability to use captured CTCs for downstream analysis. Broad clinical application is demonstrated using comparable flow rates from blood specimens obtained from breast, pancreatic, and lung cancer patients. Comparable CTC numbers are recovered in all the samples at the two flow rates, demonstrating the ability of the technology to perform at high throughputs. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Earthquake-enhanced permeability - evidence from carbon dioxide release following the ML 3.5 earthquake in West Bohemia

    NASA Astrophysics Data System (ADS)

    Fischer, T.; Matyska, C.; Heinicke, J.

    2017-02-01

    The West Bohemia/Vogtland region is characterized by earthquake swarm activity and degassing of CO2 of mantle origin. A fast increase of CO2 flow rate was observed 4 days after a ML 3.5 earthquake in May 2014 in the Hartoušov mofette, 9 km from the epicentres. During the subsequent 150 days the flow reached sixfold of the original level, and has been slowly decaying until present. Similar behavior was observed during and after the swarm in 2008 pointing to a fault-valve mechanism in long-term. Here, we present the results of simulation of gas flow in a two dimensional model of Earth's crust composed of a sealing layer at the hypocentre depth which is penetrated by the earthquake fault and releases fluid from a relatively low-permeability lower crust. This simple model is capable of explaining the observations, including the short travel time of the flow pulse from 8 km depth to the surface, long-term flow increase and its subsequent slow decay. Our model is consistent with other analyse of the 2014 aftershocks which attributes their anomalous character to exponentially decreasing external fluid force. Our observations and model hence track the fluid pressure pulse from depth where it was responsible for aftershocks triggering to the surface where a significant long-term increase of CO2 flow started 4 days later.

  5. Steel reinforced composite silicone membranes and its integration to microfluidic oxygenators for high performance gas exchange.

    PubMed

    Matharoo, Harpreet; Dabaghi, Mohammadhossein; Rochow, Niels; Fusch, Gerhard; Saraei, Neda; Tauhiduzzaman, Mohammed; Veldhuis, Stephen; Brash, John; Fusch, Christoph; Selvaganapathy, P Ravi

    2018-01-01

    Respiratory distress syndrome (RDS) is one of the main causes of fatality in newborn infants, particularly in neonates with low birth-weight. Commercial extracorporeal oxygenators have been used for low-birth-weight neonates in neonatal intensive care units. However, these oxygenators require high blood volumes to prime. In the last decade, microfluidics oxygenators using enriched oxygen have been developed for this purpose. Some of these oxygenators use thin polydimethylsiloxane (PDMS) membranes to facilitate gas exchange between the blood flowing in the microchannels and the ambient air outside. However, PDMS is elastic and the thin membranes exhibit significant deformation and delamination under pressure which alters the architecture of the devices causing poor oxygenation or device failure. Therefore, an alternate membrane with high stability, low deformation under pressure, and high gas exchange was desired. In this paper, we present a novel composite membrane consisting of an ultra-thin stainless-steel mesh embedded in PDMS, designed specifically for a microfluidic single oxygenator unit (SOU). In comparison to homogeneous PDMS membranes, this composite membrane demonstrated high stability, low deformation under pressure, and high gas exchange. In addition, a new design for oxygenator with sloping profile and tapered inlet configuration has been introduced to achieve the same gas exchange at lower pressure drops. SOUs were tested by bovine blood to evaluate gas exchange properties. Among all tested SOUs, the flat design SOU with composite membrane has the highest oxygen exchange of 40.32 ml/min m 2 . The superior performance of the new device with composite membrane was demonstrated by constructing a lung assist device (LAD) with a low priming volume of 10 ml. The LAD was achieved by the oxygen uptake of 0.48-0.90 ml/min and the CO 2 release of 1.05-2.27 ml/min at blood flow rates ranging between 8 and 48 ml/min. This LAD was shown to increase the oxygen saturation level by 25% at the low pressure drop of 29 mm Hg. Finally, a piglet was used to test the gas exchange capacity of the LAD in vivo . The animal experiment results were in accordance with in-vitro results, which shows that the LAD is capable of providing sufficient gas exchange at a blood flow rate of ∼24 ml/min.

  6. Determination of vigabatrin in plasma by reversed-phase high-performance liquid chromatography.

    PubMed

    Tsanaclis, L M; Wicks, J; Williams, J; Richens, A

    1991-05-01

    A method is described for the determination of vigabatrin in 50 microliters of plasma by isocratic high-performance liquid chromatography using fluorescence detection. The procedure involves protein precipitation with methanol followed by precolumn derivatisation with o-phthaldialdehyde reagent. Separation of the derivatised vigabatrin was achieved on a Microsorb C18 column using a mobile phase of 10 mM orthophosphoric acid:acetonitrile:methanol (6:3:1) at a flow rate of 2.0 ml/min. Assay time is 15 min and chromatograms show no interference from commonly coadministered anticonvulsant drugs. The total analytical error within the range of 0.85-85 micrograms/ml was found to be 7.6% with the within-replicates error of 2.76%. The minimum detection limit was 0.08 micrograms/ml and the minimum quantitation limit was 0.54 micrograms/ml.

  7. CO2 Washout Testing of the REI and EM-ACES Space Suits

    NASA Technical Reports Server (NTRS)

    Mitchell, Kathryn C.; Norcross, Jason

    2012-01-01

    When a space suit is used during ground testing, adequate carbon dioxide (CO2) washout must be provided for the suited subject. Symptoms of acute CO2 exposure depend on partial pressure of CO2 (ppCO2), metabolic rate of the subject, and other factors. This test was done to characterize inspired oronasal ppCO2 in the Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES) for a range of workloads and flow rates for which ground testing is nominally performed. Three subjects were tested in each suit. In all but one case, each subject performed the test twice. Suit pressure was maintained at 4.3 psid. Subjects wore the suit while resting, performing arm ergometry, and walking on a treadmill to generate metabolic workloads of about 500 to 3000 BTU/hr. Supply airflow was varied between 6, 5, and 4 actual cubic feet per minute (ACFM) at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored in real time by gas analyzers with sampling tubes connected to the mask. Metabolic rate was calculated from the total CO2 production measured by an additional gas analyzer at the suit air outlet. Real-time metabolic rate was used to adjust the arm ergometer or treadmill workload to meet target metabolic rates. In both suits, inspired CO2 was affected mainly by the metabolic rate of the subject: increased metabolic rate significantly (P < 0.05) increased inspired ppCO2. Decreased air flow caused small increases in inspired ppCO2. The effect of flow was more evident at metabolic rates . 2000 BTU/hr. CO2 washout values of the EM-ACES were slightly but not significantly better than those of the REI suit. Regression equations were developed for each suit to predict the mean inspired ppCO2 as a function of metabolic rate and suit flow rate. This paper provides detailed descriptions of the test hardware, methodology, and results as well as implications for future ground testing in the REI-suit and EM-ACES.

  8. In situ distributed diagnostics of flowable electrode systems: resolving spatial and temporal limitations.

    PubMed

    Dennison, C R; Gogotsi, Y; Kumbur, E C

    2014-09-14

    In this study, we have developed an in situ distributed diagnostics tool to investigate spatial and temporal effects in electrochemical systems based on flowable electrodes. Specifically, an experimental approach was developed that enables spatially-resolved voltage measurements to be obtained in situ, in real-time. To extract additional data from these distributed measurements, an experimentally-parameterized equivalent circuit model with a new 'flow capacitor' circuit element was developed to predict the distributions of various system parameters during operation. As a case study, this approach was applied to investigate the behavior of the suspension electrodes used in an electrochemical flow capacitor under flowing and static conditions. The volumetric capacitance is reduced from 15.6 F ml(-1) to 1.1 F ml(-1) under flowing conditions. Results indicate that the majority of the charging in suspension electrodes occurs within ∼750 μm of the current collectors during flow, which gives rise to significant state-of-charge gradients across the cell, as well as underutilization of the available active material. The underlying cause of this observation is attributed to the relatively high electrical resistance of the slurry coupled with a stratified charging regime and insufficient residence time. The observations highlight the need to develop more conductive slurries and to design cells with reduced charge transport lengths.

  9. A Very Stable High Throughput Taylor Cone-jet in Electrohydrodynamics

    PubMed Central

    Morad, M. R.; Rajabi, A.; Razavi, M.; Sereshkeh, S. R. Pejman

    2016-01-01

    A stable capillary liquid jet formed by an electric field is an important physical phenomenon for formation of controllable small droplets, power generation and chemical reactions, printing and patterning, and chemical-biological investigations. In electrohydrodynamics, the well-known Taylor cone-jet has a stability margin within a certain range of the liquid flow rate (Q) and the applied voltage (V). Here, we introduce a simple mechanism to greatly extend the Taylor cone-jet stability margin and produce a very high throughput. For an ethanol cone-jet emitting from a simple nozzle, the stability margin is obtained within 1 kV for low flow rates, decaying with flow rate up to 2 ml/h. By installing a hemispherical cap above the nozzle, we demonstrate that the stability margin could increase to 5 kV for low flow rates, decaying to zero for a maximum flow rate of 65 ml/h. The governing borders of stability margins are discussed and obtained for three other liquids: methanol, 1-propanol and 1-butanol. For a gravity-directed nozzle, the produced cone-jet is more stable against perturbations and the axis of the spray remains in the same direction through the whole stability margin, unlike the cone-jet of conventional simple nozzles. PMID:27917956

  10. Hemodynamic and neurohumoral effects of various grades of selective adenosine transport inhibition in humans. Implications for its future role in cardioprotection.

    PubMed

    Rongen, G A; Smits, P; Ver Donck, K; Willemsen, J J; De Abreu, R A; Van Belle, H; Thien, T

    1995-02-01

    In 12 healthy male volunteers (27-53 yr), a placebo-controlled randomized double blind cross-over trial was performed to study the effect of the intravenous injection of 0.25, 0.5, 1, 2, 4, and 6 mg draflazine (a selective nucleoside transport inhibitor) on hemodynamic and neurohumoral parameters and ex vivo nucleoside transport inhibition. We hypothesized that an intravenous draflazine dosage without effect on hemodynamic and neurohumoral parameters would still be able to augment the forearm vasodilator response to intraarterially infused adenosine. Heart rate (electrocardiography), systolic blood pressure (Dinamap 1846 SX; Critikon, Portanje Electronica BV, Utrecht, The Netherlands) plasma norepinephrine and epinephrine increased dose-dependently and could almost totally be abolished by caffeine pretreatment indicating the involvement of adenosine receptors. Draflazine did not affect forearm blood flow (venous occlusion plethysmography). Intravenous injection of 0.5 mg draflazine did not affect any of the measured hemodynamic parameters but still induced a significant ex vivo nucleoside-transport inhibition of 31.5 +/- 4.1% (P < 0.05 vs placebo). In a subgroup of 10 subjects the brachial artery was cannulated to infuse adenosine (0.15, 0.5, 1.5, 5, 15, and 50 micrograms/100 ml forearm per min) before and after intravenous injection of 0.5 mg draflazine. Forearm blood flow amounted 1.9 +/- 0.3 ml/100 ml forearm per min for placebo and 1.8 +/- 0.2, 2.0 +/- 0.3, 3.8 +/- 0.9, 6.3 +/- 1.2, 11.3 +/- 2.2, and 19.3 +/- 3.9 ml/100 ml forearm per min for the six incremental adenosine dosages, respectively. After the intravenous draflazine infusion, these values were 1.6 +/- 0.2 ml/100 ml forearm per min for placebo and 2.1 +/- 0.3, 3.3 +/- 0.6, 5.8 +/- 1.1, 6.9 +/- 1.4, 14.4 +/- 2.9, and 23.5 +/- 4.0 ml/100 ml forearm per min, respectively (Friedman ANOVA: P < 0.05 before vs after draflazine infusion). In conclusion, a 30-50% inhibition of adenosine transport significantly augments the forearm vasodilator response to adenosine without significant systemic effects. These results suggest that draflazine is a feasible tool to potentiate adenosine-mediated cardioprotection in man.

  11. Prevalence of Serum Celiac Antibodies in a Multiracial Asian Population-A First Study in the Young Asian Adult Population of Malaysia

    PubMed Central

    Yap, Theresa Wan-Chen; Chan, Weng-Kai; Leow, Alex Hwong-Ruey; Azmi, Ahmad Najib; Loke, Mun-Fai; Vadivelu, Jamuna; Goh, Khean-Lee

    2015-01-01

    Background Celiac disease (CD) is an immune-mediated disorder induced by the ingestion of gluten in genetically susceptible persons. The prevalence of CD in Malaysia is unknown. We aim to determine the seroprevalence of CD antibodies and also investigate the correlation between H. pylori infection and CD in the young and healthy multiracial Malaysian population. Methods Healthy young adult volunteers between the ages of 18–30 years were consecutively recruited from June 2012 to May 2014 at the University of Malaya Medical Centre (UMMC), Kuala Lumpur. Serum samples from all the participants were tested for anti-gliadin antibody immunoglobulin A/immunoglobulin G (IgA/IgG) and anti-tissue transglutaminase antibody (tTG) IgA/IgG. Samples positive for both anti-gliadin and anti-tTG were further validated for anti-human endomysial IgA antibodies (EmA). Serological diagnosis of CD was made when anti-gliadin, anti-tTG and anti-EmA were positive. Results 562 qualified participants with mean age 24 ± 2.4 years old were recruited into our study. CD was found in 7 participants where most of them were asymptomatic and unaware of their CD status. The median of anti-gliadin and anti-tTG IgA/IgG value was 38.2 U/ml (interquartile range, 28.3–60.4 U/ml) and 49.2 U/ml (interquartile range, 41.1–65.9 U/ml), respectively. Seroprevalence of CD antibodies was 1.9% (6 out of 324) in female while only 0.4% (1 out of 238) in male. Seroprevalence among Malay was 0.8% (2 of 236), Chinese was 1.7% (3 of 177) and Indian was 1.3% (2 of 149). Overall, seroprevalence of CD antibodies in healthy asymptomatic adults in the Malaysian population was 1.25% (95% CI, 0.78%-1.72%). No significant relationship was discovered between CD and H. pylori infection. Conclusions The seroprevalence of CD antibodies in healthy young adults in the Malaysian population was 1.25% (1 in 100). CD is underdiagnosed and it could be a much greater problem in Malaysia than previously thought. PMID:25799401

  12. The Effect of Symmetry on the Hydrodynamic Stability of and Bifurcation from Planar Shear Flows

    DTIC Science & Technology

    1990-12-01

    Effect of Symmetry on the Hydrodynamic Stability of ant Bifurcation from Planar Shear Flows AFOSR-88-0196 6. AUTHOR(S) 61102F 2304/A4 Thomas J. Bridges 7...December 1990 The Effect of Symmetry on the Hydrodynamic Stability of and Bifurcation from Planar Shear Flows TIIhOMAS J. BIUDGES MATl EM ATIc(AL...spatial stabili’.y into the nonlinear regime and a theory for spa- tial Hopf bifurcation , spatial Floquet theory, wavelength doubling and spatially quasi

  13. The Impact of Increased Bladder Blood Flow on Storage Symptoms after Holmium Laser Enucleation of the Prostate

    PubMed Central

    Ide, Hisamitsu; Aoki, Hiroaki; Muto, Satoru; Yamaguchi, Raizo; Tsujimura, Akira; Horie, Shigeo

    2015-01-01

    In order to investigate how holmium laser enucleation of the prostate (HoLEP) improves urinary storage symptoms, we assessed blood flow in the urinary bladder mucosa of patients with benign prostatic hyperplasia (BPH) before and after laser surgery. Seventy-four consecutive patients with BPH (median age 69 years, range; 53–88) underwent HoLEP at our institution and are included in this study. We prospectively assessed the International Prostate Symptom Score (IPSS), IPSS-QOL Score, the Overactive Bladder Symptom Score (OABSS), uroflowmetry, and blood flow in the urinary bladder, before and after surgery. Blood flow in the bladder mucosa was measured using the OMEGA FLOW (OMEGAWAVE, Tokyo, Japan) laser Doppler flowmeter. The median volume of the enucleated adenomas was 45.0 g (range: 25.0 to 83.2). The median IPSS improved significantly from 20 (range: 6–35) to 3 (0–22) (p<0.001; Wilcoxon signed-rank test), as did the storage symptoms score, which decreased from 13 (2–20) to 3 (1–8) (p<0.001). Median bladder blood flow increased at the trigone from 9.57±0.83 ml/sec to 17.60±1.08 ml/sec. Multiple regression analysis for the improved storage symptom score eliminated all explanatory variables except increased bladder perfusion. The data suggest that HoLEP improves blood flow in the bladder mucosa, which independently leads to the improvement of storage symptoms. PMID:26090819

  14. Blunted postprandial reaction of portal venous flow in chronic liver disease, assessed with duplex Doppler: significance for prognosis.

    PubMed

    de Vries, P J; de Hooge, P; Hoekstra, J B; van Hattum, J

    1994-12-01

    To establish the effects of a meal on portal venous flow and the prognostic value of this parameter, 46 patients with chronic liver disease and 28 healthy subjects were examined with duplex Doppler before and after a meal. The measurements were completed in 40 patients and 21 healthy subjects. Postprandial portal venous diameter, blood velocity and quantitative flow were measured for 60 min. Mean baseline values were: 11.4 mm versus 10.2 mm (p = 0.019), 10.8 cm.s-1 versus 13.4 cm.s-1 (p = 0.015) and 668 ml.min-1 versus 646 ml.min-1 (p = 0.7) respectively. Spleen size was 15.0 cm versus 10.6 cm (p = 0.0001) respectively. Postprandial diameter, velocity and flow increased significantly in patients and controls (p = 0.0001 for all). Mean postprandial flow could best be described by a polynomial equation with a parabolic curve. Patients' curves were more blunted than controls', with significantly different regression constants (p = 0.025 and p = 0.029). All subjects were followed up for survival and variceal haemorrhage. The mean follow-up time was 47 months. Early maximum postprandial velocity (p = 0.041) and large spleen size (p = 0.002) were significantly related to an unfavourable prognosis for survival. Early maximum velocity was also related to increased variceal haemorrhage. This study shows that postprandial portal venous flow is blunted in patients with chronic liver disease. Postprandial portal venous flow may have prognostic significance.

  15. Surface-water-quality assessment of the lower Kansas River basin, Kansas and Nebraska; dissolved oxygen and Escherichia coli bacteria in streams during low flow, July 1988 through July 1989

    USGS Publications Warehouse

    Pope, L.M.

    1995-01-01

    The 15,300-square-mile lower Kansas River Basin in Kansas and Nebraska was investigated, as one of the pilot study units of the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program, to address a variety of water-quality issues. This report describes sanitary quality of streams as defined by concentrations of dissolved oxygen (DO) and densities of a fecal-indicator bacterium, Escherichia coli (E. coli). Sixty-one surface-water sampling sites were chosen for this investigation. Synoptic surveys were conducted in July 1988, November 1988, March 1989, and May 1989 to define the concentrations and diel and seasonal variability in concentrations of DO. Synoptic surveys were conducted in July 1988 and July 1989 to define densities of E. coli. Ancillary data included measurements of specific conductance, pH, water temperature. barometric pressure, and concentrations of nutrients, total organic carbon, chlorophyll, and suspended sediment. Surveys were conducted during stable-flow, dry-weather conditions. During the July 1988 synoptic survey for DO, emphasis was placed on the measurement of DO under maximum stress (high water temperature, low streamflow, and predawn conditions). Of 31 sites sampled just before dawn, 5 had DO concentrations less than the 5.0-milligrams-perliter, l-day minimum warmwater criterion for early life stages as established by the U.S. Environmental Protection Agency (USEPA), and 4 of these 5 sites had concentrations less than the 3.0-milligrams-per-liter criterion for all other life stages. For all four synoptic surveys, a total of 392 DO determinations were made, and 9 (2.3 percent) were less than water-quality criteria. Concentrations of DO less than water-quality criteria in the study unit are localized occurrences and do not reflect regional differences in DO. The most severe DO deficiencies are the result of discharges from wastewater-treatment plants into small tributary streams with inadequate assimilation capacity. Algal respiratory demand in combination with reduced physical reaeration associated with extreme low flow probably also contributes to temporary, localized deficiencies. Densities of E. coli were determined at 57 surface-water sampling sites during the syn- optic survey in July 1988. Results indicate large regional differences in E. coli densities within the study unit. Densities orE. coli in water at 19 sites in the Big Blue River subbasin, exclusive of the Little Blue River subbasin, ranged from 120 to 260,000 col/100 mL (colonies per 100 milliliters), with a median density of 2,400 col/100 mL. Densities at the 11 sites in the Little Blue River ranged from 100 to 30,000 col/100 mL, with a median density of 940 col/100 mL. Densities at the 27 sites in the Kansas River subbasin ranged from less than 1 to 1,000 col/100 mL, with a median density of 88 col/100 mL. Densities at 84 percent of the sites in the Big Blue River subbasin exceeded the USEPA E. coli criterion of 576 col/100 mL for infrequently used full-body contact recreation, and 53 percent exceeded the 2,000 cot/I00 mL fecal coliform criterion for uses other than full-body contact established by the Kansas Department of Health and Environment. Densities at 73 percent of the sites in the Little Blue River subbasin exceeded the 576 col/100 mL E. coli criterion, and 36 percent exceeded the 2,000 col/100 mL fecal coliform criterion. Densities at one of the sites in the Kansas River subbasin exceeded the 576 col/100 mL E. coli criterion, and none exceeded the 2,000 col/100 mL fecal-coliform criterion. The largest densities of E. coli in the study unit were the result of discharges from municipal wastewater-treatment plants; however, densities in the Big Blue and Little Blue River subbasins were generally larger than those in the Kansas River subbasin. These larger densities in the Big Blue and Little Blue River subbasins may have been the result of irrigation return flow from fields where manure was used as a soil

  16. Feasibility of low contrast media volume in CT angiography of the aorta.

    PubMed

    Seehofnerová, Anna; Kok, Madeleine; Mihl, Casper; Douwes, Dave; Sailer, Anni; Nijssen, Estelle; de Haan, Michiel J W; Wildberger, Joachim E; Das, Marco

    2015-01-01

    Using smaller volumes of contrast media (CM) in CT angiography (CTA) is desirable in terms of cost reduction and prevention of contrast-induced nephropathy (CIN). The purpose was to evaluate the feasibility of low CM volume in CTA of the aorta. 77 patients referred for CTA of the aorta were scanned using a standard MDCT protocol at 100 kV. A bolus of 50 ml CM (Iopromide 300 mg Iodine/ml) at a flow rate of 6 ml/s was applied (Iodine delivery rate IDR = 1.8 g/s; Iodine load 15 g) followed by a saline bolus of 40 ml at the same flow rate. Scan delay was determined by the test bolus method. Subjective image quality was assessed and contrast enhancement was measured at 10 anatomical levels of the aorta. Diagnostic quality images were obtained for all patients, reaching a mean overall contrast enhancement of 324 ± 28 HU. Mean attenuation was 350 ± 60 HU at the thoracic aorta and 315 ± 83 HU at the abdominal aorta. A straightforward low volume CM protocol proved to be technically feasible and led to CTA examinations reaching diagnostic image quality of the aorta at 100 kV. Based on these findings, the use of a relatively small CM bolus can be incorporated into routine clinical imaging.

  17. Cutaneous blood flow in psoriasis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klemp, P.; Staberg, B.

    1983-12-01

    The disappearance rate of /sup 133/Xe was studied in 20 patients with psoriasis vulgaris, using an epicutaneous labeling technique in involved skin lesions or normal-appearing skin of the proximal extensor site of the forearm. Control experiments were performed in 10 normal subjects. Calculations of the cutaneous blood flow (CBF) in psoriatic skin lesions were performed using a tissue-to-blood partition coefficient for /sup 133/Xe, lambda c,pso, of 1.2 ml/100 g/min. lambda c,pso was estimated after the relative content of water, lipids, and proteins had been analyzed in psoriatic skin biopsies of 6 patients with untreated psoriasis. The mean relative content ofmore » water was markedly reduced to 23.5 +/- 1.5% (SEM), and lipids and proteins were markedly increased to 2.5 +/- 0.7% and 74.0 +/- 2.2, respectively, compared to previously published data for normal skin (water 72.5%, lipids 1%, proteins 26.5%). Mean CBF in untreated psoriatic skin was 63.5 +/- 9.0 ml/100 g/min. This was significantly higher than the mean CBF in 10 normal subjects, 6.3 +/- 0.5 ml/100 g/min (p much less than 0.0001). Mean CBF in normal-appearing skin in patients with psoriasis was 11.0 +/- 1.3 ml/100 g/min. This was significantly higher than CBF in normal subjects (p less than 0.0002).« less

  18. Flow injection chemiluminescence determination of the total phenolics levels in plant-derived beverages using soluble manganese(IV).

    PubMed

    Nalewajko-Sieliwoniuk, Edyta; Tarasewicz, Iwona; Kojło, Anatol

    2010-05-23

    This study established a flow injection (FI) methodology for the determination of the total phenolic content in plant-derived beverages based on soluble manganese(IV) chemiluminescence (CL) detection. It was found that mixing polyphenols with acidic soluble manganese(IV) in the presence of formaldehyde evoked chemiluminescence. Based on this finding, a new FI-CL method was developed for the estimation of the total content of phenolic compounds (expressed as milligrams of gallic acid equivalent per litre of drink) in a variety of wine, tea and fruit juice samples. The proposed method is sensitive with a detection limit of 0.02 ng mL(-1) (gallic acid), offers a wide linear dynamic range (0.5-400 ng mL(-1)) and high sample throughput (247 samples h(-1)). The relative standard deviation for 15 measurements was 3.8% for 2 ng mL(-1) and 0.45% for 10 ng mL(-1) of gallic acid. Analysis of 36 different samples showed that the results obtained by the proposed FI-CL method correlate highly with those obtained by spectrophotometric methods commonly used for the evaluation of the total phenolic/antioxidant level. However, the FI-CL method was found to be far simpler, more rapid and selective, with almost no interference from non-phenolic components of the samples examined. Copyright 2010 Elsevier B.V. All rights reserved.

  19. EM Diffusion for a Time-Domain Airborne EM System

    NASA Astrophysics Data System (ADS)

    Yin, C.; Qiu, C.; Liu, Y.; Cai, J.

    2014-12-01

    Visualization of EM diffusion for an airborne EM (AEM) system is important for understanding the transient procedure of EM diffusion. The current distribution and diffusion features also provide effective means to evaluate EM footprint, depth of exploration and further help AEM system design and data interpretation. Most previous studies on EM diffusion (or "smoke ring" effect) are based on the static presentation of EM field, where the dynamic features of EM diffusion were not visible. For visualizing the dynamic feature of EM diffusion, we first calculate in this paper the frequency-domain EM field by downward continuation of the EM field at the EM receiver to the deep earth. After that, we transform the results to time-domain via a Fourier transform. We take a homogeneous half-space and a two-layered earth induced by a step pulse to calculate the EM fields and display the EM diffusion in the earth as 3D animated vectors or time-varying contours. The "smoke ring" effect of EM diffusion, dominated by the resistivity distribution of the earth, is clearly observed. The numerical results for an HCP (vertical magnetic dipole) and a VCX (horizontal magnetic dipole) transmitting coil above a homogeneous half-space of 100 ohm-m are shown in Fig.1. We display as example only the distribution of EM field inside the earth for the diffusion time of 0.05ms. The detailed EM diffusion will be shown in our future presentation. From the numerical experiments for different models, we find that 1) the current for either an HCP or a VCX transmitting dipole propagates downward and outward with time, becoming wider and more diffuse, forming a "smoke ring"; 2) for a VCX transmitter, the underground current forms two ellipses, corresponding to the two polarities of the magnetic flux of a horizontal magnetic dipole, injecting into or ejected from the earth; 3) for a HCP transmitter, however, the underground current forms only one circle, corresponding to the polarity of the magnetic flux for a vertical magnetic dipole, injecting into the earth; 4) there exists no vertical current in an isotropic homogeneous half-space. The currents for both HCP and VCX transmitting dipole flow horizontally.

  20. Phenylalanine transfer across the isolated perfused human placenta: an experimental and modeling investigation

    PubMed Central

    Lofthouse, E. M.; Perazzolo, S.; Brooks, S.; Crocker, I. P.; Glazier, J. D.; Johnstone, E. D.; Panitchob, N.; Sibley, C. P.; Widdows, K. L.; Sengers, B. G.

    2015-01-01

    Membrane transporters are considered essential for placental amino acid transfer, but the contribution of other factors, such as blood flow and metabolism, is poorly defined. In this study we combine experimental and modeling approaches to understand the determinants of [14C]phenylalanine transfer across the isolated perfused human placenta. Transfer of [14C]phenylalanine across the isolated perfused human placenta was determined at different maternal and fetal flow rates. Maternal flow rate was set at 10, 14, and 18 ml/min for 1 h each. At each maternal flow rate, fetal flow rates were set at 3, 6, and 9 ml/min for 20 min each. Appearance of [14C]phenylalanine was measured in the maternal and fetal venous exudates. Computational modeling of phenylalanine transfer was undertaken to allow comparison of the experimental data with predicted phenylalanine uptake and transfer under different initial assumptions. Placental uptake (mol/min) of [14C]phenylalanine increased with maternal, but not fetal, flow. Delivery (mol/min) of [14C]phenylalanine to the fetal circulation was not associated with fetal or maternal flow. The absence of a relationship between placental phenylalanine uptake and net flux of phenylalanine to the fetal circulation suggests that factors other than flow or transporter-mediated uptake are important determinants of phenylalanine transfer. These observations could be explained by tight regulation of free amino acid levels within the placenta or properties of the facilitated transporters mediating phenylalanine transport. We suggest that amino acid metabolism, primarily incorporation into protein, is controlling free amino acid levels and, thus, placental transfer. PMID:26676251

  1. Integration of a Capacitive EIS Sensor into a FIA System for pH and Penicillin Determination

    PubMed Central

    Rolka, David; Poghossian, Arshak; Schöning, Michael J.

    2004-01-01

    A field-effect based capacitive EIS (electrolyte-insulator-semiconductor) sensor with a p-Si-SiO2-Ta2O5 structure has been successfully integrated into a commercial FIA (flow-injection analysis) system and system performances have been proven and optimised for pH and penicillin detection. A flow-through cell was designed taking into account the requirement of a variable internal volume (from 12 μl up to 48 μl) as well as an easy replacement of the EIS sensor. FIA parameters (sample volume, flow rate, distance between the injection valve and the EIS sensor) have been optimised in terms of high sensitivity and reproducibility as well as a minimum dispersion of the injected sample zone. An acceptable compromise between different FIA parameters has been found. For the cell design used in this study, best results have been achieved with a flow rate of 1.4 ml/min, distance between the injection valve and the EIS sensor of 6.5 cm, probe volume of 0.75 ml, cell internal volume of 12 μl. A sample throughput of at least 15 samples/h was typically obtained.

  2. Free flow isotachophoresis in an injection moulded miniaturised separation chamber with integrated electrodes.

    PubMed

    Stone, Victoria N; Baldock, Sara J; Croasdell, Laura A; Dillon, Leonard A; Fielden, Peter R; Goddard, Nick J; Thomas, C L Paul; Treves Brown, Bernard J

    2007-07-06

    An injection moulded free flow isotachophoresis (FFITP) microdevice with integrated carbon fibre loaded electrodes with a separation chamber of 36.4mm wide, 28.7 mm long and 100 microm deep is presented. The microdevice was completely fabricated by injection moulding in carbon fibre loaded polystyrene for the electrodes and crystal polystyrene for the remainder of the chip and was bonded together using ultrasonic welding. Two injection moulded electrode designs were compared, one with the electrode surface level with the separation chamber and one with a recessed electrode. Separations of two anionic dyes, 0.2mM each of amaranth and acid green and separations of 0.2mM each of amaranth, bromophenol blue and glutamate were performed on the microdevice. Flow rates of 1.25 ml min(-1) for the leading and terminating electrolytes were used and a flow rate of 0.63 ml min(-1) for the sample. Electric fields of up to 370 V cm(-1) were applied across the separation chamber. Joule heating was not found to be significant although out-gassing was observed at drive currents greater than 3 mA.

  3. Predilution versus postdilution during continuous venovenous hemofiltration: a comparison of circuit thrombogenesis.

    PubMed

    de Pont, Anne-Cornélie J M; Bouman, Catherine S C; Bakhtiari, Kamran; Schaap, Marianne C L; Nieuwland, Rienk; Sturk, Augueste; Hutten, Barbara A; de Jonge, Evert; Vroom, Margreeth B; Meijers, Joost C M; Büller, Harry R

    2006-01-01

    During continuous venovenous hemofiltration, predilution can prolong circuit survival time, but the underlying mechanism has not been elucidated. The aim of the present study was to compare predilution with postdilution, with respect to circuit thrombogenesis. Eight critically ill patients were treated with both predilutional and postdilutional continuous venovenous hemofiltration in a crossover fashion. A filtration flow of 60 ml/min was used in both modes. We chose blood flows of 140 and 200 ml/min during predilution and postdilution, respectively, to keep the total flow through the hemofilter constant. Extracorporeal circuit pressures were measured hourly, and samples of blood and ultrafiltrate were collected at five different time points. Thrombin-antithrombin complexes and prothrombin fragments F1 + 2 were measured by ELISA, and platelet activation was assessed by flow cytometry. No signs of thrombin generation or platelet activation were found during either mode. During postdilution, baseline platelet count and maximal prefilter pressure had a linear relation, whereas both parameters were inversely related with circuit survival time. In summary, predilution and postdilution did not differ with respect to extracorporeal circuit thrombogenesis. During postdilution, baseline platelet count and maximal prefilter pressure were inversely related with circuit survival time.

  4. Fracture Propagation, Fluid Flow, and Geomechanics of Water-Based Hydraulic Fracturing in Shale Gas Systems and Electromagnetic Geophysical Monitoring of Fluid Migration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Jihoon; Um, Evan; Moridis, George

    2014-12-01

    We investigate fracture propagation induced by hydraulic fracturing with water injection, using numerical simulation. For rigorous, full 3D modeling, we employ a numerical method that can model failure resulting from tensile and shear stresses, dynamic nonlinear permeability, leak-off in all directions, and thermo-poro-mechanical effects with the double porosity approach. Our numerical results indicate that fracture propagation is not the same as propagation of the water front, because fracturing is governed by geomechanics, whereas water saturation is determined by fluid flow. At early times, the water saturation front is almost identical to the fracture tip, suggesting that the fracture is mostlymore » filled with injected water. However, at late times, advance of the water front is retarded compared to fracture propagation, yielding a significant gap between the water front and the fracture top, which is filled with reservoir gas. We also find considerable leak-off of water to the reservoir. The inconsistency between the fracture volume and the volume of injected water cannot properly calculate the fracture length, when it is estimated based on the simple assumption that the fracture is fully saturated with injected water. As an example of flow-geomechanical responses, we identify pressure fluctuation under constant water injection, because hydraulic fracturing is itself a set of many failure processes, in which pressure consistently drops when failure occurs, but fluctuation decreases as the fracture length grows. We also study application of electromagnetic (EM) geophysical methods, because these methods are highly sensitive to changes in porosity and pore-fluid properties due to water injection into gas reservoirs. Employing a 3D finite-element EM geophysical simulator, we evaluate the sensitivity of the crosswell EM method for monitoring fluid movements in shaly reservoirs. For this sensitivity evaluation, reservoir models are generated through the coupled flow-geomechanical simulator and are transformed via a rock-physics model into electrical conductivity models. It is shown that anomalous conductivity distribution in the resulting models is closely related to injected water saturation, but not closely related to newly created unsaturated fractures. Our numerical modeling experiments demonstrate that the crosswell EM method can be highly sensitive to conductivity changes that directly indicate the migration pathways of the injected fluid. Accordingly, the EM method can serve as an effective monitoring tool for distribution of injected fluids (i.e., migration pathways) during hydraulic fracturing operations« less

  5. Next Generation Electromagnetic Pump Analysis Tools (PLM DOC-0005-2188). Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stregy, Seth; Dasilva, Ana; Yilmaz, Serkan

    2015-10-29

    This report provides the broad historical review of EM Pump development and details of MATRIX development under this project. This report summarizes the efforts made to modernize the legacy performance models used in previous EM Pump designs and the improvements made to the analysis tools. This report provides information on Tasks 1, 3, and 4 of the entire project. The research for Task 4 builds upon Task 1: Update EM Pump Databank and Task 3: Modernize the Existing EM Pump Analysis Model, which are summarized within this report. Where research for Task 2: Insulation Materials Development and Evaluation identified parametersmore » applicable to the analysis model with Task 4, the analysis code was updated, and analyses were made for additional materials. The important design variables for the manufacture and operation of an EM Pump that the model improvement can evaluate are: space constraints; voltage capability of insulation system; maximum flux density through iron; flow rate and outlet pressure; efficiency and manufacturability. The development of the next-generation EM Pump analysis tools during this two-year program provides information in three broad areas: Status of analysis model development; Improvements made to older simulations; and Comparison to experimental data.« less

  6. Microbes Characteristics in Groundwater Flow System in Mountainous Area

    NASA Astrophysics Data System (ADS)

    Yamamoto, Chisato; Tsujimura, Maki; Kato, Kenji; Sakakibara, Koichi; Ogawa, Mahiro; Sugiyama, Ayumi; Nagaosa, Kazuyo

    2017-04-01

    We focus on a possibility of microbes as a tracer for groundwater flow investigation. Some previous papers showed that the total number of prokaryotes in groundwater has correlation with depth and geology (Parkes et al., 1994; Griebler et al., 2009; Kato et al., 2012). However, there are few studies investigating both microbe characteristics and groundwater flow system. Therefore, we investigated a relationship between the total number of prokaryotes and age of spring water and groundwater. Intensive field survey was conducted at four mountainous areas, namely Mt. Fuji (volcano), a headwater at Mt. Setohachi, a headwater at River Oi and a headwater at River Nagano underlain by volcanic lava at Mt. Fuji, granite at Mt. Setohachi and sedimentary rock at River Oi and River Nagano. We collected totally 40 spring water/ groundwater samples in these mountainous areas in October 2015, August, October and November 2016 and analyzed concentration of inorganic ions, the stable isotopes of oxygen - 18, deuterium, CFCs and SF6. Also, we counted prokaryotic cells under the epifluorescence microscopy after fixation and filteration. The total number of prokaryotes in the spring water/ groundwater ranged from 1.0×102 to 7.0×103cells mL-1 at the Mt. Fuji, 1.3×104 to 2.7×105cells mL-1 at Mt. Setohachi, 3.1×104cells mL-1 at River Oi and 1.8×105 to 3.2×106cells mL-1 at River Nagano. The SF6 age of the spring water/ groundwater ranged from 8 to 64 years at Mt. Fuji, 2 to 32.5 years at Mt. Setohachi, 2.5 years at River Oi and 15 to 16 years at River Nagano. The total number of prokaryotes showed a clear negative correlation with residence time of spring water/ groundwater in all regions. Especially the prokaryotes number increased in the order of 102 cells mL-1 with decreasing of residence time in approximately 10 years in the groundwater and spring water with the age less than 15 years.

  7. [Immuno-affinity chromatographic purification: the study of methods to test citrinin in monascus products by high performance liquid chromatography].

    PubMed

    Qiu, Wen-qian; Liu, Xiao-xia; Zheng, Kui-cheng; Fu, Wu-sheng

    2012-08-01

    To establish a method to test citrinin (CIT) in monascus products by immuno-affinity chromatography (IAC)-high performance liquid chromatography (HPLC), and to detect the content of CIT in monascus products in Fujian province. IAC-HPLC was applied to detect the CIT content in monascus products. The conditions to use HPLC were as follows: C(18) reversed-phase chromatographic column, 150.0 mm×4.6mm×3 µm; mobile phase: the volume ratio of acetonitrile and 0.1% phosphoric acid solution at 65:35; isocratic elution; column temperature: 28°C; flow velocity: 0.8 ml/min; fluorescence detector, excitation wavelength (λ(ex)) was 331 nm and emission wavelength (λ(em)) was 500 nm. The standard curved was established by the linear regression of peak area (Y) to CIT content (X, ng/ml). The accuracy and precision of the method would then be verified. And 32 kinds of monascus products were determined and their color values were compared by this method. The standard curve established in this study was Y = 4634.8X-136.42, r = 1.000; whose limits of detection was 20 µg/kg and the limits of qualification was 64 µg/kg. In the range between 200 and 800 µg/kg, the standard recovery rate was 98.9% - 110.0% (n = 3), and the relative standard deviation (RSD) was 0.51% - 1.76%. Out of the 32 samples, CIT was detected from 11 samples of monascus rice, 9 samples of monascus powder and 5 samples of monascus pigments, the content was around 0.212 - 14.500 mg/kg. 4 out of 7 functional monascus samples were detected out CIT, whose content at 0.142 - 0.275 mg/kg. The method to detect CIT in monascus products by IAC-HPLC has been established.

  8. Pseudoephedrine: effects on milk production in women and estimation of infant exposure via breastmilk

    PubMed Central

    Aljazaf, Khalidah; Hale, Thomas W; Ilett, Kenneth F; Hartmann, Peter E; Mitoulas, Leon R; Kristensen, Judith H; Hackett, L Peter

    2003-01-01

    Aims To assess the effects of pseudoephedrine on breast blood flow, temperature and milk production, and to estimate the likely infant dose during breastfeeding. Methods Eight lactating women (mean age 35 years and weight 69 kg) participated in a single-blind randomized crossover study of 60 mg pseudoephedrine hydrochloride vs placebo. Breast blood flow and surface temperature were measured from 0 to 4 h following the dose, and change in plasma prolactin was measured as the difference between predose and 1 h postdose concentrations. Milk production was measured for 24 h following placebo and pseudoephedrine. Infant dose of pseudoephedrine for a 60-mg dose administered four times daily to the mother was quantified as the product of average steady-state drug concentration in milk and an estimated milk production rate of 0.15 l kg−1 day−1 and expressed relative to the maternal weight-adjusted dose. Results There were no physiologically significant changes in breast blood flow or temperature between the placebo and pseudoephedrine periods. The mean change in plasma prolactin was slightly (13.5%), but not significantly lower (t = 1.245, P = 0.253) after pseudoephedrine (1775 mU l−1) compared with placebo (2014 mU l−1). However, the mean milk volume was reduced by 24% from 784 ml day−1 in the placebo period to 623 ml day−1 in the pseudoephedrine period (difference between means 161 ml day−1 (95% CI: 63, 259 ml day−1); t = 3.9, P = 0.006). Assuming maternal intake of 60 mg pseudoephedrine hydrochloride four times daily, the estimated infant dose of pseudoephedrine was 4.3% (95% CI, 3.2, 5.4%) of the weight-adjusted maternal dose. Conclusions A single dose of pseudoephedrine significantly reduced milk production. This effect was not attributable to changes in blood flow, but depression of prolactin secretion may be a contributing factor. At the maximum recommended pseudoephedrine doses, the calculated infant dose delivered via milk was < 10% of the maternal dose, and is unlikely to affect the infant adversely. The ability of pseudoephedrine to suppress lactation suggests a novel use for the drug. PMID:12848771

  9. Blood flow, flow reserve, and glucose utilization in viable and nonviable myocardium in patients with ischemic cardiomyopathy

    PubMed Central

    Zhang, Xiaoli; Schindler, Thomas H.; Prior, John O.; Sayre, James; Dahlbom, Magnus; Huang, Sung-Cheng

    2016-01-01

    Purpose The aim of the study was to determine whether glucose uptake in viable myocardium of ischemic cardiomyopathy patients depends on rest myocardial blood flow (MBF) and the residual myocardial flow reserve (MFR). Methods Thirty-six patients with ischemic cardiomyopathy (left ventricular ejection fraction 25±10 %) were studied with 13N-ammonia and 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET). Twenty age-matched normals served as controls. Regional MBF was determined at rest and during dipyridamole hyperemia and regional FDG extraction was estimated from regional FDG to 13N-ammonia activity ratios. Results Rest MBF was reduced in viable (0.42±0.18 ml/min per g) and nonviable regions (0.32±0.09 ml/min per g) relative to remote regions (0.68±0.23 ml/min per g, p<0.001) and to normals (0.63±0.13 ml/min per g). Dipyridamole raised MBFs in controls, remote, viable, and nonviable regions. MBFs at rest (p<0.05) and stress (p<0.05) in viable regions were significantly higher than that in nonviable regions, while MFRs did not differ significantly (p>0.05). Compared to MFR in remote myocardium, MFRs in viable regions were similar (1.39±0.56 vs 1.70±0.45, p>0.05) but were significantly lower in nonviable regions (1.23±0.43, p<0.001). Moreover, the FDG and thus glucose extraction was higher in viable than in remote (1.40±0.14 vs 0.90±0.20, p<0.001) and in nonviable regions (1.13±0.21, p<0.001). The extraction of FDG in viable regions was independent of rest MBF but correlated inversely with MFRs (r=−0.424, p<0.05). No correlation between the FDG extraction and MFR was observed in nonviable regions. Conclusion As in the animal model, decreasing MFRs in viable myocardium are associated with increasing glucose extraction that likely reflects a metabolic adaptation of remodeling hibernating myocytes. PMID:23287994

  10. Ecological Risk Assessment of Perchlorate in Avian Species, Rodents, Amphibians and Fish: FY2003

    DTIC Science & Technology

    2005-10-01

    were weighed at the time of water change to monitor water consumption by deer mice. Animals Twenty three breeding pairs of virgin male and female...cut into small pieces and homogenized using a mortal and pestle . Wet plant material (~1g) was transferred to a 15 mL vial and extracted with 10 mL...in farmed atlantic salmon. Can Vet J 43(10):782-4 Stone, W.J., Paletta, T.L., Heiman, E.M., 1969. Toxic effects following ingestion of C-4 plastic

  11. Remodeling of the cardiovascular circulation in fetuses of mothers with diabetes: A fetal computational model analysis.

    PubMed

    Kulkarni, Aparna; Garcia-Cañadilla, Patricia; Khan, Abdullah; Lorenzo, Jose Miguel; Beckerman, Karen; Valenzuela-Alcaraz, Brenda; Cruz-Lemini, Monica; Gomez, Olga; Gratacos, Eduard; Crispi, Fatima; Bijnens, Bart

    2018-03-01

    Myocardial structural and functional abnormalities are known to occur in fetuses of mothers with diabetes mellitus (FMDM). The main aim of this investigation was to explore the cardiovascular circulatory patterns in FMDM using a validated lumped computational model of the cardiovascular system. This was a multi-institutional study involving FMDM compared to fetuses of maternal controls (FC). Fetal echocardiographic Doppler data from left and right ventricular outflow tracts, aortic isthmus, middle cerebral and umbilical arteries were fitted into a validated fetal circulation computational model to estimate patient-specific placental and vascular properties. Non-parametric comparisons were made between resistances, compliances and flows in the brain and placenta in FMDM and FC. Data from 23 FMDM and 31 FC were fitted into the model. In FMDM, compared to FC, placental relative resistance was lower (0.59 ± 0.50 versus 0.91 ± 0.41; p < .05) with higher brain relative resistance (2.36 ± 1.65 versus 1.60 ± 0.85; p < .05). Middle cerebral artery flow was lower in FMDM than FC (0.12 ± 0.14 vs. 0.27 ± 0.21 ml/min; p 0.04) with a lower cerebral-placental flow ratio. Combined stroke volume was lower in FMDM (3.65 ± 2.05 ml) than FC (4.97 ± 2.45 ml) (p 0.04). Blood flow is redistributed in FMDM to the placenta, away from the brain. This alteration may play a role in the postnatal health of these fetuses. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Engineering and Design: Precipitation/Coagulation/Flocculation

    DTIC Science & Technology

    2001-11-15

    Flocculation 7-3 7-3 Jar Test Analysis 10-1 10-3 Alternating Flow Diversion Equalization System 11-1 11-1 Intermittent Flow Diversion System...EM 1110-1-4012 15 NOV 01 (2) Polyaluminum chloride (PAC), another aluminum derivative, is a partially hydrolyzed aluminum chloride solution...derived from natural products include starch, starch derivatives, proteins, and tannins (EPA, 1987). Of these, starch is the most widely used. The

  13. [Aerodynamics study on pressure changes inside pressure-type whole-body plethysmograph produced by flowing air].

    PubMed

    Xu, Wei-Hua; Shen, Hua-Hao

    2010-02-25

    When using pressure-type plethysmography to test lung function of rodents, calculation of lung volume is always based on Boyle's law. The precondition of Boyle's law is that perfect air is static. However, air in the chamber is flowing continuously when a rodent breathes inside the chamber. Therefore, Boyle's law, a principle of air statics, may not be appropriate for measuring pressure changes of flowing air. In this study, we deduced equations for pressure changes inside pressure-type plethysmograph and then designed three experiments to testify the theoretic deduction. The results of theoretic deduction indicated that increased pressure was generated from two sources: one was based on Boyle's law, and the other was based on the law of conservation of momentum. In the first experiment, after injecting 0.1 mL, 0.2 mL, 0.4 mL of air into the plethysmograph, the pressure inside the chamber increased sharply to a peak value, then promptly decreased to horizontal pressure. Peak values were significantly higher than the horizontal values (P<0.001). This observation revealed that flowing air made an extra effect on air pressure in the plethysmograph. In the second experiment, the same volume of air was injected into the plethysmograph at different frequencies (0, 0.5, 1, 2, 3 Hz) and pressure changes inside were measured. The results showed that, with increasing frequencies, the pressure changes in the chamber became significantly higher (P<0.001). In the third experiment, small animal ventilator and pipette were used to make two types of airflow with different functions of time. The pressure changes produced by the ventilator were significantly greater than those produced by the pipette (P<0.001). Based on the data obtained, we draw the conclusion that, the flow of air plays a role in pressure changes inside the plethysmograph, and the faster the airflow is, the higher the pressure changes reach. Furthermore, the type of airflow also influences the pressure changes.

  14. Effect of beam hardening on transmural myocardial perfusion quantification in myocardial CT imaging

    NASA Astrophysics Data System (ADS)

    Fahmi, Rachid; Eck, Brendan L.; Levi, Jacob; Fares, Anas; Wu, Hao; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.

    2016-03-01

    The detection of subendocardial ischemia exhibiting an abnormal transmural perfusion gradient (TPG) may help identify ischemic conditions due to micro-vascular dysfunction. We evaluated the effect of beam hardening (BH) artifacts on TPG quantification using myocardial CT perfusion (CTP). We used a prototype spectral detector CT scanner (Philips Healthcare) to acquire dynamic myocardial CTP scans in a porcine ischemia model with partial occlusion of the left anterior descending (LAD) coronary artery guided by pressure wire-derived fractional flow reserve (FFR) measurements. Conventional 120 kVp and 70 keV projection-based mono-energetic images were reconstructed from the same projection data and used to compute myocardial blood flow (MBF) using the Johnson-Wilson model. Under moderate LAD occlusion (FFR~0.7), we used three 5 mm short axis slices and divided the myocardium into three LAD segments and three remote segments. For each slice and each segment, we characterized TPG as the mean "endo-to-epi" transmural flow ratio (TFR). BH-induced hypoenhancement on the ischemic anterior wall at 120 kVp resulted in significantly lower mean TFR value as compared to the 70 keV TFR value (0.29+/-0.01 vs. 0.55+/-0.01 p<1e-05). No significant difference was measured between 120 kVp and 70 keV mean TFR values on segments moderately affected or unaffected by BH. In the entire ischemic LAD territory, 120 kVp mean endocardial flow was significantly reduced as compared to mean epicardial flow (15.80+/-10.98 vs. 40.85+/-23.44 ml/min/100g; p<1e-04). At 70 keV, BH was effectively minimized resulting in mean endocardial MBF of 40.85+/-15.3407 ml/min/100g vs. 74.09+/-5.07 ml/min/100g (p=0.0054) in the epicardium. We also found that BH artifact in the conventional 120 kVp images resulted in falsely reduced MBF measurements even under non-ischemic conditions.

  15. In Vitro Validation of Real-Time Three-Dimensional Color Doppler Echocardiography for Direct Measurement of Proximal Isovelocity Surface Area in Mitral Regurgitation

    PubMed Central

    Little, Stephen H.; Igo, Stephen R.; Pirat, Bahar; McCulloch, Marti; Hartley, Craig J.; Nosé, Yukihiko; Zoghbi, William A.

    2012-01-01

    The 2-dimensional (2D) color Doppler (2D-CD) proximal isovelocity surface area (PISA) method assumes a hemispheric flow convergence zone to estimate transvalvular flow. Recently developed 3-dimensional (3D)-CD can directly visualize PISA shape and surface area without geometric assumptions. To validate a novel method to directly measure PISA using real-time 3D-CD echocardiography, a circulatory loop with an ultrasound imaging chamber was created to model mitral regurgitation (MR). Thirty-two different regurgitant flow conditions were tested using symmetric and asymmetric flow orifices. Three-dimensional–PISA was reconstructed from a hand-held real-time 3D-CD data set. Regurgitant volume was derived using both 2D-CD and 3D-CD PISA methods, and each was compared against a flowmeter standard. The circulatory loop achieved regurgitant volume within the clinical range of MR (11 to 84 ml). Three-dimensional–PISA geometry reflected the 2D geometry of the regurgitant orifice. Correlation between the 2D-PISA method regurgitant volume and actual regurgitant volume was significant (r2 = 0.47, p <0.001). Mean 2D-PISA regurgitant volume underestimate was 19.1 ± 25 ml (2 SDs). For the 3D-PISA method, correlation with actual regurgitant volume was significant (r2 = 0.92, p <0.001), with a mean regurgitant volume underestimate of 2.7 ± 10 ml (2 SDs). The 3D-PISA method showed less regurgitant volume underestimation for all orifice shapes and regurgitant volumes tested. In conclusion, in an in vitro model of MR, 3D-CD was used to directly measure PISA without geometric assumption. Compared with conventional 2D-PISA, regurgitant volume was more accurate when derived from 3D-PISA across symmetric and asymmetric orifices within a broad range of hemodynamic flow conditions. PMID:17493476

  16. Micromachined lab-on-a-tube sensors for simultaneous brain temperature and cerebral blood flow measurements.

    PubMed

    Li, Chunyan; Wu, Pei-Ming; Hartings, Jed A; Wu, Zhizhen; Cheyuo, Cletus; Wang, Ping; LeDoux, David; Shutter, Lori A; Ramaswamy, Bharat Ram; Ahn, Chong H; Narayan, Raj K

    2012-08-01

    This work describes the development of a micromachined lab-on-a-tube device for simultaneous measurement of brain temperature and regional cerebral blood flow. The device consists of two micromachined gold resistance temperature detectors with a 4-wire configuration. One is used as a temperature sensor and the other as a flow sensor. The temperature sensor operates with AC excitation current of 500 μA and updates its outputs at a rate of 5 Hz. The flow sensor employs a periodic heating and cooling technique under constant-temperature mode and updates its outputs at a rate of 0.1 Hz. The temperature sensor is also used to compensate for temperature changes during the heating period of the flow sensor to improve the accuracy of flow measurements. To prevent thermal and electronic crosstalk between the sensors, the temperature sensor is located outside the "thermal influence" region of the flow sensor and the sensors are separated into two different layers with a thin-film Copper shield. We evaluated the sensors for accuracy, crosstalk and long-term drift in human blood-stained cerebrospinal fluid. These in vitro experiments showed that simultaneous temperature and flow measurements with a single lab-on-a-tube device are accurate and reliable over the course of 5 days. It has a resolution of 0.013 °C and 0.18 ml/100 g/min; and achieves an accuracy of 0.1 °C and 5 ml/100 g/min for temperature and flow sensors respectively. The prototype device and techniques developed here establish a foundation for a multi-sensor lab-on-a-tube, enabling versatile multimodality monitoring applications.

  17. Evaporative water loss in man in a gravity-free environment

    NASA Technical Reports Server (NTRS)

    Leach, C. S.; Leonard, J. I.; Rambaut, P. C.; Johnson, P. C.

    1978-01-01

    Daily evaporative water losses (EWL) during the three Skylab missions were measured indirectly using mass and water-balance techniques. The mean daily values of EWL for the nine crew members who averaged 1 hr of daily exercise were: preflight 1,750 + or - 37 (SE) ml or 970 + or - 20 ml/sq m and inflight 1,560 + or - 26 ml or 860 + or - 14 ml/sq m. Although it was expected the EWL would increase in the hypobaric environment of Skylab, an average decrease from preflight sea-level conditions of 11% was measured. The results suggest that weightlessness decreased sweat losses during exercise and possibly reduced insensible skin losses. The weightlessness environment apparently promotes the formation of an observed sweat film on the skin surface during exercise by reducing convective flow and sweat drippage, resulting in high levels of skin wettedness that favor sweat suppression.

  18. Anatomic pulmonary resection via video-assisted thoracic surgery: analysis of 117 cases at a referral center in Brazil.

    PubMed

    Soder, Stephan Adamour; Barth, Frederico; Perin, Fabiola Adelia; Felicetti, José Carlos; Camargo, José de Jesus Peixoto; Camargo, Spencer Marcantônio

    2017-01-01

    To describe our experience with video-assisted thoracic surgery (VATS) for anatomic pulmonary resection at a referral center for thoracic surgery in Brazil. All patients who underwent anatomic pulmonary resection by VATS between 2010 and 2015 were included. Clinical and pathological data, as well as postoperative complications, were analyzed. A total of 117 pulmonary resections by VATS were performed, of which 98 were lobectomies and 19 were anatomic segmentectomies. The mean age of the patients was 63.6 years (range, 15-86 years). Females predominated (n = 69; 59%). The mean time to chest tube removal was 2.47 days, and the mean length of ICU stay was 1.88 days. The mean length of hospital stay was 4.48 days. Bleeding ≥ 400 mL occurred in 15 patients. Conversion to thoracotomy was required in 4 patients. Our results are similar to those published in major international studies, indicating that VATS is an important strategy for pulmonary resection. They also show that VATS can be safely performed with adequate training. This technique should be used more often for the treatment of lung diseases in Brazil. Relatar a experiência com cirurgia torácica videoassistida (CTVA) para ressecções pulmonares anatômicas em um centro nacional de referência de cirurgia torácica no Brasil. Foram incluídos todos os pacientes tratados com ressecções pulmonares anatômicas por CTVA entre 2010 e 2015 e analisados dados clínicos e patológicos, assim como complicações pós-operatórias. Foram realizadas 117 ressecções pulmonares por CTVA, sendo 98 lobectomias e 19 segmentectomias anatômicas. A média de idade foi de 63,6 anos (variação, 15-86 anos), sendo a maioria mulheres (n = 69; 59%). A média de tempo de permanência com dreno foi de 2,47 dias e a de estada em UTI foi de 1,88 dias. A média de tempo de internação foi de 4,48 dias. Sangramento ≥ 400 ml ocorreu em 15 pacientes. Houve conversão para toracotomia em 4 pacientes. Nossos resultados vão ao encontro de publicações em grandes séries internacionais, corroborando que a CTVA é uma importante via de execução de ressecções pulmonares e que pode ser realizada com segurança quando há treinamento adequado, devendo ser mais utilizada no Brasil para o tratamento das doenças pulmonares.

  19. Electromigration and Thermomechanical Fatigue Behavior of Sn0.3Ag0.7Cu Solder Joints

    NASA Astrophysics Data System (ADS)

    Zuo, Yong; Bieler, Thomas R.; Zhou, Quan; Ma, Limin; Guo, Fu

    2017-12-01

    The anisotropy of Sn crystal structures greatly affects the electromigration (EM) and thermomechanical fatigue (TMF) of solder joints. The size of solder joint shrinkage in electronic systems further makes EM and TMF an inseparably coupled issue. To obtain a better understanding of failure under combined moderately high (2000 A/cm2) current density and 10-150°C/1 h thermal cycling, analysis of separate, sequential, and concurrent EM and thermal cycling (TC) was imposed on single shear lap joints, and the microstructure and crystal orientations were incrementally characterized using electron backscatter diffraction (EBSD) mapping. First, it was determined that EM did not significantly change the crystal orientation, but the formation of Cu6Sn5 depended on the crystal orientation, and this degraded subsequent TMF behavior. Secondly, TC causes changes in crystal orientation. Concurrent EM and TC led to significant changes in crystal orientation by discontinuous recrystallization, which is facilitated by Cu6Sn5 particle formation. The newly formed Cu6Sn5 often showed its c-axis close to the direction of electron flow.

  20. Electromigration and Thermomechanical Fatigue Behavior of Sn0.3Ag0.7Cu Solder Joints

    NASA Astrophysics Data System (ADS)

    Zuo, Yong; Bieler, Thomas R.; Zhou, Quan; Ma, Limin; Guo, Fu

    2018-03-01

    The anisotropy of Sn crystal structures greatly affects the electromigration (EM) and thermomechanical fatigue (TMF) of solder joints. The size of solder joint shrinkage in electronic systems further makes EM and TMF an inseparably coupled issue. To obtain a better understanding of failure under combined moderately high (2000 A/cm2) current density and 10-150°C/1 h thermal cycling, analysis of separate, sequential, and concurrent EM and thermal cycling (TC) was imposed on single shear lap joints, and the microstructure and crystal orientations were incrementally characterized using electron backscatter diffraction (EBSD) mapping. First, it was determined that EM did not significantly change the crystal orientation, but the formation of Cu6Sn5 depended on the crystal orientation, and this degraded subsequent TMF behavior. Secondly, TC causes changes in crystal orientation. Concurrent EM and TC led to significant changes in crystal orientation by discontinuous recrystallization, which is facilitated by Cu6Sn5 particle formation. The newly formed Cu6Sn5 often showed its c-axis close to the direction of electron flow.

  1. Increased resting cerebral blood flow in adult Fabry disease: MRI arterial spin labeling study.

    PubMed

    Phyu, Po; Merwick, Aine; Davagnanam, Indran; Bolsover, Fay; Jichi, Fatima; Wheeler-Kingshott, Claudia; Golay, Xavier; Hughes, Deralynn; Cipolotti, Lisa; Murphy, Elaine; Lachmann, Robin H; Werring, David John

    2018-04-17

    To assess resting cerebral blood flow (CBF) in the whole-brain and cerebral white matter (WM) and gray matter (GM) of adults with Fabry disease (FD), using arterial spin labeling (ASL) MRI, and to investigate CBF correlations with WM hyperintensity (WMH) volume and the circulating biomarker lyso-Gb3. This cross-sectional, case-control study included 25 patients with genetically confirmed FD and 18 age-matched healthy controls. We quantified resting CBF using Quantitative Signal Targeting With Alternating Radiofrequency Labeling of Arterial Regions (QUASAR) ASL MRI. We measured WMH volume using semiautomated software. We measured CBF in regions of interest in whole-brain, WM, and deep GM, and assessed correlations with WMH volume and plasma lyso-Gb3. The mean age (% male) for FD and healthy controls was 42.2 years (44%) and 37.1 years (50%). Mean whole-brain CBF was 27.56 mL/100 mL/min (95% confidence interval [CI] 23.78-31.34) for FD vs 22.39 mL/100 mL/min (95% CI 20.08-24.70) for healthy controls, p = 0.03. In WM, CBF was higher in FD (22.42 mL/100 mL/min [95% CI 17.72-27.12] vs 16.25 mL/100 mL/min [95% CI 14.03-18.48], p = 0.05). In deep GM, CBF was similar between groups (40.41 mL/100 mL/min [95% CI 36.85-43.97] for FD vs 37.46 mL/100 mL/min [95% CI 32.57-42.35], p = 0.38). In patients with FD with WMH (n = 20), whole-brain CBF correlated with WMH volume ( r = 0.59, p = 0.006), not with plasma lyso-Gb3. In FD, resting CBF is increased in WM but not deep GM. In FD, CBF correlates with WMH, suggesting that cerebral perfusion changes might contribute to, or result from, WM injury. © 2018 American Academy of Neurology.

  2. A comparison of the hourly output between the Ambu® Smart-Infuser™ Pain Pump and the On-Q Pump® with Select-A-Flow™ Variable Rate Controller with standard and overfill volumes.

    PubMed

    Iliev, Peter; Bhalla, Tarun; Tobias, Joseph D

    2016-04-01

    The Ambu Smart-Infuser Pain Pump and the On-Q Pump with Select-a-Flow Variable Rate Controller are elastomeric devices with a flow regulator that controls the rate of infusion of a local anesthetic agent through a peripheral catheter. As a safety evaluation, we evaluated the infusion characteristics of these two devices when filled with manufacturer recommended standard volumes and when overfilled with a volume 50% in excess of that which is recommended. Nineteen disposable devices from the two manufacturers were used in this study. Nine were filled with 0.9% normal saline according to the respective manufacturers' recommendations (four Ambu pumps were filled with 650 ml and five On-Q pumps were filled with 550 ml) and 10 devices were 150% overfilled (five Ambu pumps were filled with 975 ml and five On-Q pumps were filled with 825 ml). All of the devices were set to infuse at 10 ml · h(-1) at room temperature (21°C) for 12 h. The fluid delivered during each 2-h period was measured using a graduated column. The On-Q pump (in the settings of normal fill and 150% overfill) delivered a significantly higher output per hour than the set rate during the first 8 h, while the Ambu pump delivered a value close to the set rate of 10 ml · h(-1). No significant difference in the hourly delivered output was noted for either device when comparing the normal fill to the 150% overfill groups. This investigation demonstrates that no change in the hourly output occurs with overfilling of these home infusion devices. However, as noted previously, the hourly output from the On-Q device is significantly higher than the set rate during the initial 8 h of infusion which could have potential clinical implications. © 2016 John Wiley & Sons Ltd.

  3. Assessing the Value of Information of Geophysical Data For Groundwater Management

    NASA Astrophysics Data System (ADS)

    Trainor, W. J.; Caers, J. K.; Mukerji, T.; Auken, E.; Knight, R. J.

    2008-12-01

    Effective groundwater management requires hydrogeologic models informed by various data sources. The long-term goal of our research is to develop methodologies that quantify the value of information (VOI) of geophysical data for water managers. We present an initial sensitivity study on assessing the reliability of airborne electro-magnetic (EM) data for detecting channel orientation. The reliability results are used to calculate VOI regarding decisions of artificial recharge to mitigate seawater intrusion. To demonstrate how a hydrogeologic problem can be framed in decision analysis terms, a hypothetical example is built, where water managers are considering artificial recharge to remediate seawater intrusion. Is the cost of recharge justified given the large uncertainty of subsurface heterogeneity that may interfere in a successful recharge? Thus, the decision is should recharge be performed, and if yes, where should recharge wells be located? This decision is difficult because of the large uncertainty of the aquifer heterogeneity that influences flow. The expected value of all possible outcomes to the decision without gathering additional EM information is the prior value VPRIOR. The value of information (VOI) is calculated as the expected gain in value after including the relevant new information, or the difference between the value after a free experiment (VFE) and the value prior (VPRIOR): VOI = VFE - VPRIOR Airborne EM has been used to detect confining clay layers and flow barriers. However, geophysical information rarely identifies the subsurface perfectly. Many challenges impact data quality and the resulting models (interpretation uncertainty). To evaluate how well airborne EM data detect the orientation of subsurface channel systems, 125 alternative binary, fluvial lithology models are generated, each categorized into one of three subsurface scenarios: northwest, southwest and mixed channel orientation. Using rock property relations, the lithology models are converted into electrical resistivity models for EM forward modeling, to generate time-domain EM data. Noise is added to the late times of the EM data to better represent typical airborne acquisition. Inversions are performed to obtain 125 inverted resistivity images. From the images, we calculate the angle of maximum spatial correlation at every cell, and compare it with the truth - the original lithology model. These synthetic models serve as a proxy to estimate misclassification probabilities of channel orientation from actual EM data. The misclassification probabilities are then used in the VOI calculations. Results are presented demonstrating how the reliability measure and the pumping schedule can impact VOI. Lastly, reliability and VOI are calculated and compared for land-based EM data, which has different spatial sampling and resolution than air-borne data.

  4. Long-term efficacy of Serenoa repens treatment in patients with mild and moderate symptomatic benign prostatic hyperplasia.

    PubMed

    Sinescu, Ioanel; Geavlete, Petrisor; Multescu, Razvan; Gangu, Constantin; Miclea, Florin; Coman, Ioan; Ioiart, Ioan; Ambert, Valentin; Constantin, Traian; Petrut, Bogdan; Feciche, Bogdan

    2011-01-01

    The study aimed to evaluate the long-term efficacy of treatment with extract of Serenoa repens (Prostamol Uno) in patients with lower urinary tract symptoms (LUTS) induced by benign prostatic hyperplasia (BPH). We studied 120 patients with mild or moderate LUTS induced by BPH, maximal urinary flow (Q(max)) <15 ml with a voided volume ≥150 ml, prostate-specific antigen <4 ng/ml, and residual urinary volume <150 ml, treated daily for 24 months with one capsule of 320 mg ethanolic extract of Serenoa repens. Statistically significant improvements in the International Prostate Symptom Score (5.5 points), quality of life (QoL; 1.8 points), Q(max) (5.6 ml/s), International Index of Erectile Function (IIEF; 6.4 points) and reduction in residual urinary volume were observed during the study period. The mean prostate volume at 24 months was 36 ml, compared to 39.8 ml at baseline. Long-term treatment with 320 mg ethanolic extract of Serenoa repens proved to be efficient in reducing urinary obstruction, improving symptomatology and QoL of BPH patients. It also had a positive effect on sexual function, demonstrated by the statistically significant increase in the IIEF. Copyright © 2011 S. Karger AG, Basel.

  5. Molecular characterisation and the protective immunity evaluation of Eimeria maxima surface antigen gene.

    PubMed

    Liu, Tingqi; Huang, Jingwei; Li, Yanlin; Ehsan, Muhammad; Wang, Shuai; Zhou, Zhouyang; Song, Xiaokai; Yan, Ruofeng; Xu, Lixin; Li, Xiangrui

    2018-05-30

    Coccidiosis is recognised as a major parasitic disease in chickens. Eimeria maxima is considered as a highly immunoprotective species within the Eimeria spp. family that infects chickens. In the present research, the surface antigen gene of E. maxima (EmSAG) was cloned, and the ability of EmSAG to stimulate protection against E. maxima was evaluated. Prokaryotic and eukaryotic plasmids expressing EmSAG were constructed. The EmSAG transcription and expression in vivo was performed based on the RT-PCR and immunoblot analysis. The expression of EmSAG in sporozoites and merozoites was detected through immunofluorescence analyses. The immune protection was assessed based on challenge experiments. Flow cytometry assays were used to determine the T cell subpopulations. The serum antibody and cytokine levels were evaluated by ELISA. The open reading frame (ORF) of EmSAG gene contained 645 bp encoding 214 amino acid residues. The immunoblot and RT-PCR analyses indicated that the EmSAG gene were transcribed and expressed in vivo. The EmSAG proteins were expressed in sporozoite and merozoite stages of E. maxima by the immunofluorescence assay. Challenge experiments showed that both pVAX1-SAG and the recombinant EmSAG (rEmSAG) proteins were successful in alleviating jejunal lesions, decreasing loss of body weight and the oocyst ratio. Additionally, these experiments possessed anticoccidial indices (ACI) of more than 170. Higher percentages of CD4 + and CD8 + T cells were detected in both EmSAG-inoculated birds than those of the negative control groups (P < 0.05). The EmSAG-specific antibody concentrations of both the rEmSAG and pVAX1-EmSAG groups were much higher than those of the negative controls (P < 0.05). Higher concentrations of IL-4, IFN-γ, TGF-β1 and IL-17 were observed more in both the rEmSAG protein and pVAX1-SAG inoculated groups than those of negative controls (P < 0.05). Our findings suggest that EmSAG is capable of eliciting a moderate immune protection and could be used as an effective vaccine candidate against E. maxima.

  6. Indirect-response modeling of desmopressin at different levels of hydration.

    PubMed

    Callréus, T; Odeberg, J; Lundin, S; Höglund, P

    1999-10-01

    The objective of the present study was to investigate the pharmacokinetics (PK) and pharmacodynamics (PD) of desmopressin in healthy male subjects at different levels of overhydration. Also, we examined if an indirect-response model could be related to renal physiology and the pharmacological action of desmopressin. Eight healthy male subjects participated in this open, randomized crossover study with three periods. Each subject was orally water loaded (0 to 20 ml.kg-1 body weight) on 3 study days in order to achieve three different levels of hydration. After the initial water load, urine was voided every 15 min and the volumes were measured. To ensure continuous overhydration the subjects replaced their fluid loss with drinking-water. When a steady-state diuresis was achieved after approximately 2 hr, 0.396 microgram of desmopressin was administered intravenously as a bolus injection. Blood was sampled and urine was collected at intervals throughout the study day (10 hr). An indirect-response model, where desmopressin was assumed to inhibit the elimination of response, was fit to the urine osmolarity data. There were no statistically significant effects of different levels of hydration, as expressed by urine flow rate at baseline, on the estimates of the PK and PD model parameters. The calculated terminal half-lives of elimination (t1/2 beta) ranged between 2.76 and 8.37 hr with an overall mean of 4.36 hr. The overall means of plasma clearance and the volumes of distribution of the central compartment (Vc) and at steady state (Vss) were estimated to be 1.34 (SD 0.35) ml.min-1.kg-1, 151 (SD28) ml.kg-1, and 386 (SD 63) ml.kg-1, respectively. High urine flow rate, indicating overhydration, produced a diluted urine and thus a low osmolarity at baseline (R0). The effect of the urine flow rate on the urine osmolarity at baseline was highly significant (p < 0.0001). The mean values for IC50 and the sigmodicity factor (gamma) were 3.7 (SD 1.2) pg ml-1 and 13.0 (SD 3.5), respectively. In most cases when there was a high urine flow rate at baseline, the model and the estimated PD parameters could be related to the pharmacological action of desmopressin and renal physiology. Thus, the indirect-response model used in this study offers a mechanistic approach of modeling the effect of desmopressin in overhydrated subjects.

  7. Proteinase-activated receptor (PAR)-2 activation impacts bone resorptive properties of human osteoarthritic subchondral bone osteoblasts.

    PubMed

    Amiable, Nathalie; Tat, Steeve Kwan; Lajeunesse, Daniel; Duval, Nicolas; Pelletier, Jean-Pierre; Martel-Pelletier, Johanne; Boileau, Christelle

    2009-06-01

    In osteoarthritis (OA), the subchondral bone undergoes a remodelling process involving several factors synthesized by osteoblasts. In this study, we investigated the expression, production, modulation, and role of PAR-2 in human OA subchondral bone osteoblasts. PAR-2 expression and production were determined by real-time PCR and flow cytometry, respectively. PAR-2 modulation was investigated in OA subchondral bone osteoblasts treated with IL-1 beta (100 pg/ml), TNF-alpha (5 ng/ml), TGF-beta1 (10 ng/ml), PGE(2) (500 nM), IL-6 (10 ng/ml) and IL-17 (10 ng/ml). Membranous RANKL protein was assessed by flow cytometry, and OPG, MMP-1, MMP-9, MMP-13, IL-6 and intracellular signalling pathways by specific ELISAs. Bone resorptive activity was measured by using a co-culture model of human PBMC and OA subchondral bone osteoblasts. PAR-2 expression and production (p<0.05) were markedly increased when human OA subchondral bone osteoblasts were compared to normal. On OA osteoblasts, PAR-2 production was significantly increased by IL-1 beta, TNF-alpha and PGE(2). Activation of PAR-2 with a specific agonist, SLIGKV-NH(2), induced a significant up-regulation of MMP-1, MMP-9, IL-6, and membranous RANKL, but had no effect on MMP-13 or OPG production. Interestingly, bone resorptive activity was also significantly enhanced following PAR-2 activation. The PAR-2 effect was mediated by activation of the MAP kinases Erk1/2 and JNK. This study is the first to demonstrate that PAR-2 activation plays a role in OA subchondral bone resorption via an up-regulation of major bone remodelling factors. These results shed new light on the potential of PAR-2 as a therapeutic target in OA.

  8. Morphology based scoring of chromosomal instability and its correlation with cell viability.

    PubMed

    Yadav, Shubhlata; Bhatia, Alka

    2017-09-01

    The aim of this study was to devise the quantitative scoring system for Chromosomal instability (CIN) based on morphological indicators like MPM, NB, NPB, CS, La and MN in cancer cell line and to correlate it with cell viability and death. Human hepatocellular carcinoma (HepG2) cells were treated with drugs like Diethylstilbestrol 0-100μM, Griseofulvin 0-40μg/ml, Vincristine sulphate 0-25μg/ml, Mitomycin C 0-600ng/ml, Bleomycin 0-10μg/ml, Doxorubicin 0-30μg/ml for 24h. Following this, the CIN was assessed by counting the morphological indicators like Micronuclei (MN), Nuclear Buds (NB), Nucleoplasmic bridges, Laggards, Multipolar mitosis and chromatin strings/1000 cells in Giemsa stained smears by light microscopy and by determining the percentage of aneuploid cells by flow cytometry. The cell viability was assessed by MTT assay and percentage of apoptotic cells was determined by flow cytometry. The MN and NB were most frequently seen indicators and main determinants of morphological CIN. However, the morphological CIN score did not show any correlation with cell viability and apoptosis. Aneuploidy however was found to correlate positively with cell viability and NB score in our study (P-value <0.05). The study for the 1st time attempted to develop a scoring system for CIN based on morphological parameters. However, a no correlation was observed between the later and cell viability or apoptosis. More robust techniques to quantify CIN may perhaps be more helpful in exploring the true link between CIN and cell viability in future. Copyright © 2017 Elsevier GmbH. All rights reserved.

  9. On-line preconcentration and speciation of arsenic by flow injection hydride generation atomic absorption spectrophotometry.

    PubMed

    Narcise, Cristine Ingrid S; Coo, Lilibeth Dlc; Del Mundo, Florian R

    2005-12-15

    A flow injection-column preconcentration-hydride generation atomic absorption spectrophotometric (FI-column-HGAAS) method was developed for determining mug/l levels of As(III) and As(V) in water samples, with simultaneous preconcentration and speciation. The speciation scheme involved determining As(V) at neutral pH and As(III+V) at pH 12, with As(III) obtained by difference. The enrichment factor (EF) increased with increase in sample loading volume from 2.5 to 10ml, and for preconcentration using the chloride-form anion exchange column, EFs ranged from 5 to 48 for As(V) and 4 to 24 for As(III+V), with corresponding detection limits of 0.03-0.3 and 0.07-0.3mug/l. Linear concentration range (LCR) also varied with sample loading volume, and for a 5-ml sample was 0.3-5 and 0.2-8mug/l for As(V) and As(III+V), respectively. Sample throughput, which decreased with increase in sample volume, was 8-17 samples/h. For the hydroxide-form column, the EFS for 2.5-10ml samples were 3-23 for As(V) and 2-15 for As(III+V), with corresponding detection limits of 0.07-0.4 and 0.1-0.5mug/l. The LCR for a 5-ml sample was 0.3-10mug/l for As(V) and 0.2-20mug/l for As(III+V). Sample throughput was 10-20 samples/h. The developed method has been effectively applied to tap water and mineral water samples, with recoveries ranging from 90 to 102% for 5-ml samples passed through the two columns.

  10. The effect of an inhaled neutral endopeptidase inhibitor, thiorphan, on airway responses to neurokinin A in normal humans in vivo.

    PubMed

    Cheung, D; Bel, E H; Den Hartigh, J; Dijkman, J H; Sterk, P J

    1992-06-01

    Neuropeptides such as neurokinin A (NKA) have been proposed as important mediators of bronchoconstriction and airway hyperresponsiveness in asthma. Inhaled NKA causes bronchoconstriction in patients with asthma, but not in normal subjects. This is possibly due to the activity of an endogenous neuropeptide-degrading enzyme: neutral endopeptidase (NEP). We investigated whether a NEP-inhibitor, thiorphan, reveals bronchoconstriction to NKA or NKA-induced changes in airway responsiveness to methacholine in normal humans in vivo. Eight normal male subjects participated in a double-blind crossover study, using thiorphan as pretreatment to NKA challenge. Dose-response curves to inhaled NKA (8 to 1,000 micrograms/ml, 0.5 ml/dose) were recorded on 2 randomized days 1 wk apart, and methacholine tests were performed 48 h before and 24 h after the NKA challenge. Ten minutes prior to NKA challenge the subjects inhaled either thiorphan (2.5 mg/ml, 0.5 ml) or placebo. To detect a possible nonspecific effect of thiorphan, we investigated the effect of the same pretreatment with thiorphan or placebo on the dose-response curve to methacholine in a separate set of experiments. The response was measured by the flow from standardized partial expiratory flow-volume curves (V40p), expressed in percent fall from baseline. NKA log dose-response curves were analyzed using the area under the curve (AUC) and the response to the highest dose of 1,000 micrograms/ml (V40p,1000). The methacholine dose-response curves were characterized by their position (PC40V40p) and the maximal-response plateau (MV40p). Baseline V40p was not affected by either pretreatment (p greater than 0.15).(ABSTRACT TRUNCATED AT 250 WORDS)

  11. Effect of antioxidants on histamine receptor activation and sustained post-exercise vasodilatation in humans

    PubMed Central

    Romero, Steven A.; Ely, Matthew R.; Sieck, Dylan C.; Luttrell, Meredith J.; Buck, Tahisha M.; Kono, Jordan M.; Branscum, Adam J.; Halliwill, John R.

    2015-01-01

    An acute bout of aerobic exercise elicits a sustained post-exercise vasodilatation that is mediated by histamine H1 and H2 receptor activation. However, the upstream signaling pathway that leads to post-exercise histamine receptor activation is unknown. We tested the hypothesis that the potent antioxidant ascorbate would inhibit this histaminergic vasodilatation following exercise. Subjects performed 1 hr unilateral dynamic knee extension at 60% of peak power in three conditions: 1) control; 2) intravenous ascorbate infusion; and, 3) ascorbate infusion plus oral H1/H2 histamine receptor blockade. Femoral artery blood flow (Doppler ultrasound) was measured before exercise and for 2 hr post-exercise. Femoral vascular conductance was calculated as flow/pressure. Post-exercise vascular conductance was greater for control condition (3.4 ± 0.1 ml min−1 mmHg−1) compared with ascorbate (2.7 ± 0.1 ml min−1 mmHg−1, P < 0.05) and ascorbate plus H1/H2 blockade (2.8 ± 0.1 ml min−1 mmHg−1, P < 0.05), which did not differ from one another (P = 0.9). Because ascorbate may catalyze the degradation of histamine in vivo, we conducted a follow-up study where subjects performed exercise in two conditions: 1) control and 2) intravenous N-acetylcysteine infusion. Post-exercise vascular conductance was similar for control (4.0 ± 0.1 ml min−1 mmHg−1) and N-acetylcysteine conditions (4.0 ± 0.1 ml min−1 mmHg−1; P = 0.8). Thus, the results in study 1 were due to the degradation of histamine in skeletal muscle by ascorbate, since the histaminergic vasodilatation was unaffected by N-acetylcysteine. Taken together, exercise-induced oxidative stress does not appear to contribute to sustained post-exercise vasodilatation. PMID:25664905

  12. On the uncertainty in single molecule fluorescent lifetime and energy emission measurements

    NASA Technical Reports Server (NTRS)

    Brown, Emery N.; Zhang, Zhenhua; Mccollom, Alex D.

    1995-01-01

    Time-correlated single photon counting has recently been combined with mode-locked picosecond pulsed excitation to measure the fluorescent lifetimes and energy emissions of single molecules in a flow stream. Maximum likelihood (ML) and least square methods agree and are optimal when the number of detected photons is large however, in single molecule fluorescence experiments the number of detected photons can be less than 20, 67% of those can be noise and the detection time is restricted to 10 nanoseconds. Under the assumption that the photon signal and background noise are two independent inhomogeneous poisson processes, we derive the exact joint arrival time probably density of the photons collected in a single counting experiment performed in the presence of background noise. The model obviates the need to bin experimental data for analysis, and makes it possible to analyze formally the effect of background noise on the photon detection experiment using both ML or Bayesian methods. For both methods we derive the joint and marginal probability densities of the fluorescent lifetime and fluorescent emission. the ML and Bayesian methods are compared in an analysis of simulated single molecule fluorescence experiments of Rhodamine 110 using different combinations of expected background nose and expected fluorescence emission. While both the ML or Bayesian procedures perform well for analyzing fluorescence emissions, the Bayesian methods provide more realistic measures of uncertainty in the fluorescent lifetimes. The Bayesian methods would be especially useful for measuring uncertainty in fluorescent lifetime estimates in current single molecule flow stream experiments where the expected fluorescence emission is low. Both the ML and Bayesian algorithms can be automated for applications in molecular biology.

  13. On the Uncertainty in Single Molecule Fluorescent Lifetime and Energy Emission Measurements

    NASA Technical Reports Server (NTRS)

    Brown, Emery N.; Zhang, Zhenhua; McCollom, Alex D.

    1996-01-01

    Time-correlated single photon counting has recently been combined with mode-locked picosecond pulsed excitation to measure the fluorescent lifetimes and energy emissions of single molecules in a flow stream. Maximum likelihood (ML) and least squares methods agree and are optimal when the number of detected photons is large, however, in single molecule fluorescence experiments the number of detected photons can be less than 20, 67 percent of those can be noise, and the detection time is restricted to 10 nanoseconds. Under the assumption that the photon signal and background noise are two independent inhomogeneous Poisson processes, we derive the exact joint arrival time probability density of the photons collected in a single counting experiment performed in the presence of background noise. The model obviates the need to bin experimental data for analysis, and makes it possible to analyze formally the effect of background noise on the photon detection experiment using both ML or Bayesian methods. For both methods we derive the joint and marginal probability densities of the fluorescent lifetime and fluorescent emission. The ML and Bayesian methods are compared in an analysis of simulated single molecule fluorescence experiments of Rhodamine 110 using different combinations of expected background noise and expected fluorescence emission. While both the ML or Bayesian procedures perform well for analyzing fluorescence emissions, the Bayesian methods provide more realistic measures of uncertainty in the fluorescent lifetimes. The Bayesian methods would be especially useful for measuring uncertainty in fluorescent lifetime estimates in current single molecule flow stream experiments where the expected fluorescence emission is low. Both the ML and Bayesian algorithms can be automated for applications in molecular biology.

  14. Effect of N-acetyl cysteine on orthodontic primers cytotoxicity.

    PubMed

    D'Antò, Vincenzo; Spagnuolo, Gianrico; Schweikl, Helmut; Rengo, Sandro; Ambrosio, Luigi; Martina, Roberto; Valletta, Rosa

    2011-02-01

    The aims of this study were to evaluate the cytotoxicity of four orthodontic primers, including two hydrophilic and two hydrophobic materials, and to investigate the role of the reactive oxygen species (ROS) in induced cell damage. Moreover, the effects of the anti-oxidant N-acetyl cysteine (NAC) on primers toxicity was analyzed. Human gingival fibroblasts (HGF) were exposed to different concentrations of primers (0-0.25 mg/ml) in the presence or absence of NAC, and the cytotoxicity was assessed by the MTT assay, while cell death was quantified by flow cytometry after propidium iodide staining. The increase in the induced ROS levels was detected by flow cytometry measuring the fluorescence of the oxidation-sensitive dye 2',7'-dichlorofluorescein diacetate (DCFH-DA). All materials decreased cell viability in a dose-related manner after a 24 h exposure period. Cytotoxicity of orthodontic primers based on concentrations which caused a 50% decrease in cell viability (TC₅₀) in HGF was ranked as follows (median values): Eagle Fluorsure (0.078 mg/ml)>Transbond XT (0.081 mg/ml)>Transbond MIP (0.128 mg/ml)>Ortho solo (0.130 mg/ml). Moreover, in HGF cells, all materials induced a dose-dependent increase in ROS levels compared to untreated cells. Incubation of HGF with NAC significantly reduced ROS production and decreased the cell damage and cytotoxicity caused by all materials tested (p<0.001). Our results suggested that hydrophilic primers were less cytotoxic than hydrophobic materials. Moreover, we demonstrated a major role of ROS in the induction of cell death since the antioxidant N-acetyl cysteine was able to prevent cell damage induced by all materials tested. Copyright © 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  15. The effect of vitamin D on renin-angiotensin system activation and blood pressure: a randomized control trial.

    PubMed

    McMullan, Ciaran J; Borgi, Lea; Curhan, Gary C; Fisher, Naomi; Forman, John P

    2017-04-01

    Disruption of vitamin D signaling in rodents causes activation of the rennin-angiotensin system (RAS) and development of hypertension. Observational studies in humans found lower circulating 25-hydroxyvitamin D [25(OH)D] is associated with increased RAS activity and blood pressure (BP). We performed the first randomized control trial to investigate the effects of vitamin D supplementation on the RAS in humans. Vitamin D deficient, [25(OH)D ≤20 ng/ml), overweight individuals without hypertension were randomized into a double-blind, placebo-controlled trial of 8-weeks treatment with ergocalciferol or placebo. Kidney-specific RAS activity, measured using renal plasma flow response to captopril in high sodium balance, was assessed at baseline and 8 weeks, as was systemic RAS activity and 24-h ambulatory BP. In total, 84 participants completed the study. Mean 25[OH]D levels increased from 14.7 to 30.3 ng/ml in the ergocalciferol group, P value < 0.0001, and from 14.3 to 17.4 ng/ml in the placebo group, P value = 0.3. The renal plasma flow response to captopril was 33.9 ± 56.1 ml/min per 1.73 m at baseline and 35.7 ± 47.7 ml/min per 1.73 m at 8 weeks in the ergocalciferol group (P value = 0.83); and was 37.3 ± 46.9 ml/min per 1.73 m at baseline and 35.9 ± 26.2 ml/min per 1.73 m at 8 weeks in the placebo group (P value = 0.78). Ergocalciferol had no effect on PRA, AngII, or 24-h BP measurements. This trial found no benefit from correcting vitamin D deficiency on RAS activity or BP after 8 weeks. These findings are not consistent with the hypothesis that vitamin D is a modifiable target for lowering BP in vitamin D deficient individuals.

  16. Initial in vitro evaluation of a pediatric vortex-mixing membrane lung.

    PubMed

    Peacock, J A; Bellhouse, B J; Abel, K; Bellhouse, E L; Bellhouse, F H; Jeffree, M A; Sykes, M K; Gardaz, J P

    1983-05-01

    A new design for a pediatric membrane lung is described in this paper. The lung consists of eight blood compartments, each having six U-shaped blood channels, with microporous PTFE membranes supported on rigid plates in such a way that the membranes form furrowed blood channels. Two rolling diaphragm pumps are attached to the open ends of the U-shaped blood channels; these pumps are operated in antiphase. Mean flow is provided by a roller pump placed at the inlet end of the membrane lung. Pulsatile blood flow within the blood channels produces successive vortex formation and ejection, leading to good blood mixing and high efficiency in gas transport. The design of the rolling diaphragm piston pumps ensures that the blood prime volume is low (280 ml), and the grouping of the pumps at one end of the oxygenator allows the driving mechanism to be simple and compact. The relatively wide blood channels (minimum width 0.5 mm) and vortex mixing make priming the membrane lung particularly easy. The membrane area is 0.39 m2. Preliminary performance testing of the pediatric membrane lung was undertaken by pumping blood around a circuit containing a roller pump, the membrane lung, and a bubble oxygenator (to adjust the blood gases at the inlet to the membrane lung). In five such experiments it was shown that the membrane lung transferred 80 ml O2/min and 120 ml CO2/min at a blood flow rate of 1.5 L/min.

  17. Determination of the herbicide benfuresate by its photo-induced chemiluminescence using flow multicommutation methodology.

    PubMed

    Albert-García, J R; Calatayud, J Martínez

    2008-05-15

    The present paper deals with an analytical strategy based on coupling photo-induced chemiluminescence in a multicommutation continuous-flow methodology for the determination of the herbicide benfuresate. The solenoid valve inserted as small segments of the analyte solution was sequentially alternated with segments of the NaOH solution for adjusting the medium for the photodegradation. Both flow rates (sample and medium) were adjusted to required time for photodegradation, 90 s; and then, the resulting solution was also sequentially inserted as segments alternated with segments of the oxidizing solution system, hexacyanoferrate (III) in alkaline medium. The calibration range from 1 microg L(-1) to 95 mg L(-1), resulted in a linear behaviour over the range 1 microg L(-1) to 4 mg L(-1) and fitting the linear equation: I=4555.7x+284.2, correlation coefficient 0.9999. The limit of detection was 0.1 microg L(-1) (n=5, criteria 3 sigma) and the sample throughput was 22 h(-1). The consumption of solutions was very small; per peak were 0.66 mL, 0.16 mL and 0. 32 mL sample, medium and oxidant, respectively. Inter- and intra-day reproducibility resulted in a R.S.D. of 3.9% and 3.4%, respectively. After testing the influence of a large series of potential interferents the method is applied to water samples obtained from different places, human urine and to one formulation.

  18. Effects of varying hematocrit on intestinal oxygen uptake in neonatal lambs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holzman, I.R.; Tabata, B.; Edelstone, D.I.

    1985-04-01

    The authors chronically catheterized 15 newborn lambs (9.5 +/- 2.8 days) and measured intestinal blood flow (Qi) by the radionuclide microsphere technique at hematocrit levels ranging from 10 to 55%. Seven animals were made progressively anemic and eight polycythemic by means of exchange transfusions. Using the Fick principle, they calculated intestinal oxygen delivery (Di O/sub 2/), oxygen consumption (Vi O/sub 2/), and oxygen extraction. Initial base-line values were Qi = 195.5 ml . min-1 . 100 g intestine-1, Di O/sub 2/ = 22.1 ml . min-1 . 100 g-1, Vi O/sub 2/ = 4.8 ml . min-1 . 100 g-1,more » and O/sub 2/ extraction = 22.5%. As the hematocrit was lowered, Di O/sub 2/ decreased and O2 extraction increased and vice versa when the hematocrit was raised. Vi O/sub 2/ remained constant, but Qi did not correlate with changes in hematocrit. However, intestinal blood flow, as a percent distribution of total blood flow, decreased with lower hematocrit levels. At no time was there any evidence of anaerobic metabolism as measured by excess lactate production. The data indicate that the intestines of neonatal lambs are capable of maintaining their metabolic needs over a wide range of oxygen availability induced by a changing hematocrit. The primary mechanism is through alteration of oxygen extraction. Within the range of the experiments, no critically low oxygen availability was attained at which anaerobic metabolism became significant.« less

  19. Synthesis of ACNT on quartz substrate with catalytic decomposition reaction from Cinnamomum camphora by using FC-CVD method

    NASA Astrophysics Data System (ADS)

    Wulan, Praswasti P. D. K.; Silaen, Toni Partogi Johannes

    2017-05-01

    Camphor is a renewable carbon source that can be used as raw material for synthesizing Carbon Nanotube (CNT). Camphor is a substance that can be found on the Cinnamomum camphora tree. In this research, the method used to synthesize Aligned Carbon Nanotube (ACNT) from camphor is Floating Catalyst Chemical Vapor Deposition (FC-CVD) with Ferrocene as catalyst at temperature of 800°C, hydrogen gas as the co-reactant and argon gas as carrier gas. This method is the most popular method of synthesizing ACNT which oriented and have a high density. Camphor decomposes into benzene, toluene, and xylene at a temperature of 800°C. By using GC-FID for characterization test, the results showed decomposition at a temperature of 800°C camphor dominated by benzene with a concentration of 92.422 to 97.656%. The research was conducted by varying the flow rate of carrier gas such as argon at 40, 55, 70, 85 and 100 mL / min at a temperature of 800°C for 60 minutes of reaction time. Argon carrier gas flow rate of 70 mL / min producing CNT with the highest yield, but this is not followed by best quality of CNT. CNT with best quality is obtained at a flow rate of argon carrier gas at 55 mL / min based on test results characterization by using SEM, EDX, Mapping, and RAMAN Spectroscopy. This research have not obtained CNT with aligned structured.

  20. The Cardiovascular Effects of Morphine THE PERIPHERAL CAPACITANCE AND RESISTANCE VESSELS IN HUMAN SUBJECTS

    PubMed Central

    Zelis, Robert; Mansour, Edward J.; Capone, Robert J.; Mason, Dean T.

    1974-01-01

    To evaluate the effects of morphine on the peripheral venous and arterial beds, 69 normal subjects were evaluated before and after the intravenous administration of 15 mg morphine. Venous tone was determined by three independent techniques in 22 subjects. The venous pressure measured in a hand vein during temporary circulatory arrest (isolated hand vein technique) fell from 20.2±1.4 to 13.4±0.9 mm Hg (P < 0.01) 10 min after morphine, indicating that a significant venodilation had occurred. With the acute occlusion technique, morphine induced a reduction in forearm venous tone from 12.8±1.1 to 7.9±2.3 mm Hg/ml/100 ml (P < 0.01). Although forearm venous volume at a pressure of 30 mm Hg (VV[30]) was increased from 2.26±0.17 to 2.55±0.26 ml/100 ml, measured by the equilibration technique, the change was not significant (P > 0.1). Of note is that the initial reaction to morphine was a pronounced venoconstriction, demonstrated during the first 1-2 min after the drug. (Isolated hand vein pressure increased to 37.2±5.4 mm Hg, P < 0.01). This rapidly subsided, and by 5 min a venodilation was evident. Morphine did not attenuate the venoconstrictor response to a single deep breath, mental arithmetic, or the application of ice to the forehead when measured by either the isolated hand vein technique or the equilibration technique. To evaluate the effects of morphine on the peripheral resistance vessels in 47 normal subjects, forearm blood flow was measured plethysmographically before and 10-15 min after the intravenous administration of 15 mg of morphine. Although mean systemic arterial pressure was unchanged, forearm blood flow increased from 2.92±0.28 to 3.96±0.46 ml/min/100 ml (P < 0.01), and calculated vascular resistance fell from 42.4±5.2 to 31.6±3.2 mm Hg/ml/min/100 ml (P < 0.01). When subjects were tilted to the 45° head-up position, morphine did not block the increase in total peripheral vascular resistance that occurs; however, it did significantly attenuate the forearm arteriolar constrictor response (before morphine, + 25.7±5.4; after morphine, + 13.7±5.3 mm Hg/ml/min/100 ml, P < 0.05). However, morphine did not block the post-Valsalva overshoot of blood pressure, nor did it block the increase in forearm vascular resistance produced by the application of ice to the forehead. Similarly, morphine did not block the arteriolar or venoconstrictor effects of intra-arterially administered norepinephrine. Morphine infused into the brachial artery in doses up to 200 μg/min produced no changes in ipsilateral forearm VV[30], forearm blood flow, or calculated forearm resistance. Intra-arterial promethazine, atropine, and propranolol did not block the forearm arteriolar dilator response to intravenous morphine; however, intra-arterial phentolamine abolished the response. These data suggest that in human subjects, morphine induces a peripheral venous and arteriolar dilation by a reflex reduction in sympathetic alpha adrenergic tone. Morphine does not appear to act as a peripheral alpha adrenergic blocking agent but seems to attenuate the sympathetic efferent discharge at a central nervous system level. Images PMID:4612057

Top