Henn, S; Monfort, P; Vigneron, J H; Hoffman, M A; Hoffman, M
1999-10-01
To investigate the stability of methacholine chloride in 0.9% sodium chloride solutions. Methacholine powder was mixed with diluent to a final concentration of 5 and 10 mg/ml. Duplicates of each admixture were divided and stored in glass vials at 25 degrees C, 4 degrees C and -20 degrees C for 12 months. At appropriate times intervals, samples were removed from solutions and analysed. Methacholine concentrations were measured using a high performance capillary electrophoresis assay. No colour or other visual changes were seen in any sample. However, an additional peak was observed in some samples. Methacholine chloride solutions 5 mg/ml were stable in isotonic sodium chloride after refrigeration or freezing over a period of one year; methacholine chloride solutions 10 mg/ml were stable for one year after freezing. The solutions stored at ambient temperature were stable for 35 days and for less than 14 days, respectively, for the 5 and the 10 mg/ml solutions.
Baytak, Sitki; Türker, A Rehber
2006-02-28
Lead and nickel were preconcentrated as their ethylenediaminetetraacedic acid (EDTA) complexes from aqueous sample solutions using a column containing Ambersorb-572 and determined by flame atomic absorption spectrometry (FAAS). pH values, amount of solid phase, elution solution and flow rate of sample solution have been optimized in order to obtain quantitative recovery of the analytes. The effect of interfering ions on the recovery of the analytes has also been investigated. The recoveries of Pb and Ni under the optimum conditions were 99 +/- 2 and 97 +/- 3%, respectively, at 95% confidence level. Seventy-five-fold (using 750 mL of sample solution and 10 mL of eluent) and 50-fold (using 500 mL of sample solution and 10 mL of eluent) preconcentration was obtained for Pb and Ni, respectively. Time of analysis is about 4.5 h (for obtaining enrichment factor of 75). By applying these enrichment factors, the analytical detection limits of Pb and Ni were found as 3.65 and 1.42 ng mL(-1), respectively. The capacity of the sorbent was found as 0.17 and 0.21 mmol g(-1) for Pb and Ni, respectively. The interferences of some cations, such as Mn2+, Co2+, Fe3+, Al3+, Zn2+, Cd2+, Ca2+, Mg2+, K+ and Na+ usually present in water samples were also studied. This procedure was applied to the determination of lead and nickel in parsley, green onion, sea water and waste water samples. The accuracy of the procedure was checked by determining Pb and Ni in standard reference tea leaves sample (GBW-07605). The results demonstrated good agreement with the certified values.
[Studies for analyzing restricted ingredients such as phenylbenzoimidazole sulfonic acid].
Tokunaga, Hiroshi; Mori, Kenichiro; Onuki, Nahomi; Nosaka, Tomio; Doi, Kayo; Sakaguchi, Hiroshi; Fujii, Makiko; Takano, Katuhiro; Hayashi, Masato; Yoshizawa, Kenichi; Shimamura, Kimio; Sato, Nobuo
2006-01-01
Phenylbenzoimidazol sulfonic acid (PBS) is a kind of sunscreens in cosmetics and is nominated as the restricted ingredients in cosmetics in Japanese Pharmaceutical Affairs Act. So the analytical method for PBS was investigated by HPLC. 1.0 g of the lotions with 1.0% PBS was exactly weighed, put into a 50-mL volumetric flask. Water was added to make exactly 50 mL and this mixture was used as the sample solution. On the other hand, 1.0 g of the creams with 1.0% PBS was exactly weighed, put into a beaker. After adding 1 mL of tetrahydrofuran and dissolving the cream, that mixture was transferred to a 50-mL volumetric flask. And then the beaker was rinsed with 1 mL of tetrahydrofuran and the rinsed solution was put together into the volumetric flask. After adding water to the volumetric flask to make exactly 50 mL, this mixture was used as the sample solution. If necessary, the mixture was filtrated with a membrane filter (0.45 microm). 5.0 mL of the sample solution was pipetted and put into a 200-mL volumetric flask. After adding water to make exactly 200 mL, 20 microL of this solution was analyzed by HPLC using the ODS column (CAPCELL PAK C18 column, 4.6 mm i.d. x 250 mm), the mixture of 40 mmol/L acetic buffer (pH 3.4) and acetonitrile (3:1) with 0.8 mmol/L dodecyltrimethyl ammonium bromide and the detection wavelength of 305 nm. The working curve from 0.5 to 20.0 microg/mL showed a linear line between the concentrations of PBS and the peak areas. There was no interference of peak of PBS from the lotion and cream.
21 CFR 172.133 - Dimethyl dicarbonate.
Code of Federal Regulations, 2014 CFR
2014-04-01
... titration Reference electrode Glass electrode reagents Acetone, analytical-grade Solution of 1 N... sample (W) and dissolve in 100 mL acetone. Add accurately 25 mL of the 1 N diisobutylamine solution by... the diisobutylamine solution, always use the same pipette and wait for a further three drops to fall...
Baxa MicroMacrocompounder for parenteral nutrition solutions in a pediatric hospital.
Combeau, D; Rey, J B; Fontan, J E; Nouaille-Degorce, B; Brion, F
1999-01-01
The constant increase of parenteral nutrition (PN) manufacturing in our pediatric hospital led us to look for an automatic filling system. The aim of this study was to evaluate the MicroMacrocompounder (MM23) for compounding pediatric PN solutions. MM23 volumetric accuracy was tested with its different inlets (S, D, V) for volumes of sterile water for injection from 0.2 to 2900 mL. The influence of the solution viscosity and the source solution bottle replacements during the filling operation was also investigated. Manufacturing pediatric PN solutions was eventually assessed. Time to set up the system was 30 minutes. Maximum filling speeds with sterile water for injection were 860, 330, 154 mL/min for Vx, V and D inlets, respectively. Inlet S was not tested for MM23 filling speed. Minimal flush volume of 40 mL of sterile water for injection is necessary to clear the tube of residual ions. Average MM23 volumetric accuracy was < 5% for volumes > or = 0.5 mL for S and D inlets, and for volumes > or = 20 mL for V inlet. The volumetric accuracy was equal to 6.25% for 0.2 mL. In all experiments, volumetric accuracy was < 5%. The accuracy of electrolyte measurements performed on bag samples was less than 5% for 150 (74%) samples, between 5 and 10% for 27 (13%) samples and greater than 10% for 27 (13%) samples. Microbiological analysis showed no positive culture. The average manufacturing times were 56.8 +/- 4.5, 188.2 +/- 7.7 and 447.2 +/- 13.8 seconds for 130, 660 and 1800 mL bags, respectively. The MM23 compounder is suitable for compounding pediatric admixtures with source solutions volumes > or = 0.5 mL. This system has been used daily for five months in our department.
Wen, Yingying; Li, Jinhua; Yang, Fangfang; Zhang, Weiwei; Li, Weiran; Liao, Chunyang; Chen, Lingxin
2013-03-15
A novel method for the simultaneous separation and determination of four benzimidazole fungicides (i.e., carbendazim, fuberidazole, thiophanate-methyl and thiophanate) in high salinity samples was developed by using salting-out assisted liquid-liquid extraction (SALLE) via water-miscible acetonitrile as the extractant coupled with high-performance liquid chromatography. Box-Behnken design and response surface were employed to assist the optimization of SALLE conditions, including volume of salting-out solvent, the pH of sample solution and salting-out solvent as variable factors. The optimal salting-out parameters were obtained as follows: 2 mL of acetonitrile was added to 2 mL of sample solution with pH=4 and then 2 mL salting-out solvent containing 5 mol L(-1) sodium chloride at a pH of 7 was added to the solution for extraction. This procedure afforded a convenient and cost-saving operation with good cleanup ability for the benzimidazole fungicides, such as good linear relationships (R>0.996) between peak area and concentration from 2.5 ng mL(-1) to 500 ng mL(-1), low limits of detection between 0.14 ng mL(-1) and 0.38 ng mL(-1) and the intra-day precisions of retention time below 1.0%. The method recoveries obtained at fortified three concentrations for three seawater samples ranged from 60.4% to 99.1%. The simple, rapid and eco-benign SALLE based method proved potentially applicable for trace benzimidazole fungicides analysis in high salinity samples. Copyright © 2012 Elsevier B.V. All rights reserved.
Irala, Luis Eduardo Duarte; Grazziotin-Soares, Renata; Salles, Alexandre Azevedo; Munari, Aline Zen; Pereira, Joseani Santos
2010-01-01
This in vitro study evaluated (1) the dissolution of bovine pulp tissue in solutions consisting of varying NaOCl concentrations and combined with EDTA; and (2) the pH of these solutions before and after the experiment. The independent variables were the concentration and the volume of the solution. Thirty bovine pulps were divided in equal fragments, resulting in 90 fragments of pulp tissue. Each fragment was immersed in one of the following solutions: 1% NaOCl (4 ml), 2.5% NaOCl (4 ml), 1% NaOCl + 17% EDTA (2 ml : 2 ml), 1% NaOCl + 17% EDTA (1 ml : 3 ml), 2.5% NaOCl + 17% EDTA (2 ml : 2 ml), and 2.5% NaOCl + 17% EDTA (1 ml : 3 ml). The test solutions were dichotomized as either able or not able to dissolve the tissue, the latter being attributed when the dissolution of the pulp tissue was not complete within 48 hours. When the samples were able to dissolve the tissue, the time required for complete tissue dissolution was submitted to statistical analysis. The pH of the solutions was measured before and after the experiment. The pH variable was dichotomized as either changed or unchanged. The results demonstrated that the NaOCl solutions combined with 17% EDTA were not able to dissolve the tissue. The t-test revealed that the 2.5% NaOCl solution presented a lower mean dissolution time than the 1% NaOCl solution (p < 0.001). The pH of the solutions with equal volumes of NaOCl and EDTA decreased in 48 hours.
27 CFR 21.111 - Gentian violet.
Code of Federal Regulations, 2012 CFR
2012-04-01
... on 1 ml of sulfuric acid; it dissolves in the acid with an orange or brown-red color. When this... gram of sample to a 150 ml beaker containing 50 ml of alcohol. Stir to complete solution and filter...
27 CFR 21.111 - Gentian violet.
Code of Federal Regulations, 2013 CFR
2013-04-01
... on 1 ml of sulfuric acid; it dissolves in the acid with an orange or brown-red color. When this... gram of sample to a 150 ml beaker containing 50 ml of alcohol. Stir to complete solution and filter...
27 CFR 21.111 - Gentian violet.
Code of Federal Regulations, 2010 CFR
2010-04-01
... on 1 ml of sulfuric acid; it dissolves in the acid with an orange or brown-red color. When this... gram of sample to a 150 ml beaker containing 50 ml of alcohol. Stir to complete solution and filter...
27 CFR 21.111 - Gentian violet.
Code of Federal Regulations, 2011 CFR
2011-04-01
... on 1 ml of sulfuric acid; it dissolves in the acid with an orange or brown-red color. When this... gram of sample to a 150 ml beaker containing 50 ml of alcohol. Stir to complete solution and filter...
27 CFR 21.111 - Gentian violet.
Code of Federal Regulations, 2014 CFR
2014-04-01
... on 1 ml of sulfuric acid; it dissolves in the acid with an orange or brown-red color. When this... gram of sample to a 150 ml beaker containing 50 ml of alcohol. Stir to complete solution and filter...
Britt, J S; Carson, M C; von Bredow, J D; Condon, R J
1999-09-15
To determine whether there would be detectable antibiotic residues in milk obtained from dairy cattle with papillomatous digital dermatitis (PDD) after topical treatment with oxytetracycline. Randomized controlled clinical trial. 28 lactating Holstein cows with PDD. Cows were assigned to 2 treatment groups. Treatment 1 (n = 16) consisted of spraying of PDD lesions with 15 ml of a solution containing 100 mg of oxytetracycline/ml; lesions were sprayed twice daily for 7 days, using a garden sprayer. Treatment 2 (n = 12) consisted of a one-time application of a bandage that consisted of cotton soaked with 20 ml of a solution containing 100 mg of oxytetracycline/ml. Milk samples were obtained before and after treatment and assayed for tetracycline content by use of high-performance liquid chromatography and a commercially available tetracycline screening test. None of the cows in either treatment group had violative residues of oxytetracycline in milk samples. Producers treating lactating cows that have PDD, via topical application of oxytetracycline solution at the concentrations reported in this study, have a low risk of causing violative antibiotic residues in milk.
Katsumata, Hideyuki; Kaneco, Satoshi; Suzuki, Tohru; Ohta, Kiyohisa
2006-09-08
A sensitive and selective column adsorption method is proposed for the preconcentration and determination of atrazine and simazine. Atrazine and simazine were preconcentrated on heat-treated diatomaceous earth as an adsorbent and then determined by high-performance liquid chromatography (HPLC). Several parameters on the recoveries of the analytes were investigated. The experimental results showed that it was possible to obtain quantitative analysis when the solution pH was 2 using 100 mL of validation solution containing 1.5 microg of triazines and 5 mL of ethanol as an eluent. Recoveries of atrazine and simazine were 95.7+/-4.2% and 75.0+/-1.9% with a relative standard deviation for seven determinations of 4.7% and 2.7% under optimum conditions. The maximum preconcentration factor was 100 for triazines when 500 mL of sample solution volume was used. The linear ranges of calibration curves for atrazine and simazine were 1-150 ng mL(-1) and 1-300 ng mL(-1), respectively, with correlation coefficients of 0.999 and the detection limits (3Signal-to-Noise) were 0.24 ng mL(-1) and 0.21 ng mL(-1) for atrazine and simazine. The capacity of the adsorbent was also examined and found to be 0.8 mg g(-1) and 1.3 mg g(-1) for atrazine and simazine, respectively. The proposed method was successfully applied to the determination of triazines in river water and tap water samples with high precision and accuracy.
Preparation of fatty acid methyl esters for gas-liquid chromatography[S
Ichihara, Ken'ichi; Fukubayashi, Yumeto
2010-01-01
A convenient method using commercial aqueous concentrated HCl (conc. HCl; 35%, w/w) as an acid catalyst was developed for preparation of fatty acid methyl esters (FAMEs) from sterol esters, triacylglycerols, phospholipids, and FFAs for gas-liquid chromatography (GC). An 8% (w/v) solution of HCl in methanol/water (85:15, v/v) was prepared by diluting 9.7 ml of conc. HCl with 41.5 ml of methanol. Toluene (0.2 ml), methanol (1.5 ml), and the 8% HCl solution (0.3 ml) were added sequentially to the lipid sample. The final HCl concentration was 1.2% (w/v). This solution (2 ml) was incubated at 45°C overnight or heated at 100°C for 1–1.5 h. The amount of FFA formed in the presence of water derived from conc. HCl was estimated to be <1.4%. The yields of FAMEs were >96% for the above lipid classes and were the same as or better than those obtained by saponification/methylation or by acid-catalyzed methanolysis/methylation using commercial anhydrous HCl/methanol. The method developed here could be successfully applied to fatty acid analysis of various lipid samples, including fish oils, vegetable oils, and blood lipids by GC. PMID:19759389
Hernández González, Carolina; Cabezas, Alberto J Quejido; Díaz, Marta Fernández
2005-11-15
A 100-fold preconcentration procedure based on rare-earth elements (REEs) separation from water samples with an extraction chromatographic column has been developed. The separation of REEs from matrix elements (mainly Fe, alkaline and alkaline-earth elements) in water samples was performed loading the samples, previously acidified to pH 2.0 with HNO(3), in a 2ml column preconditioned with 20ml 0.01M HNO(3). Subsequently, REEs were quantitatively eluted with 20ml 7M HNO(3). This solution was evaporated to dryness and the final residue was dissolved in 10ml 2% HNO(3) containing 1mugl(-1) of cesium used as internal standard. The solution was directly analysed by inductively coupled plasma mass spectrometry (ICP-MS), using ultrasonic nebulization, obtaining quantification limits ranging from 0.05 to 0.10 ngl(-1). The proposed method has been applied to granitic waters running through fracture fillings coated by iron and manganese oxy-hydroxides in the area of the Ratones (Cáceres, Spain) old uranium mine.
Nakajima, Junichi; Ohno, Masashi; Chikama, Katsumi; Seki, Tatsuya; Oguma, Koichi
2009-09-15
A flow injection analysis (FIA) method using on-line separation and preconcentration with a novel metal scavenger beads, QuadraSil TA, has been developed for the ICP-OES determination of traces of palladium. QuadraSil TA contains diethylenetriamine as a functional group on spherical silica beads and shows the highest selectivity for Pd(II) at pH 1 (0.1 mol l(-1) hydrochloric acid) solution. An aliquot of the sample solution prepared as 0.1 mol l(-1) in hydrochloric acid was passed through the QuadraSil TA column. After washing the column with the carrier solution, the Pd(II) retained on the column was eluted with 0.05 mol l(-1) thiourea solution and the eluate was directly introduced into an ICP-OES. The proposed method was successfully applied to the determination of traces of palladium in JSd-2 stream sediment certified reference material [0.019+/-0.001 microg g(-1) (n=3); provisional value: 0.0212 microg g(-1)] and SRM 2556 used auto catalyst certified reference material [315+/-4 microg g(-1) (n=4); certified value: 326 microg g(-1)]. The detection limit (3 sigma) of 0.28 ng ml(-1) was obtained for 5 ml of sample solution. The sample through puts for 5 ml and 100 microl of the sample solutions were 10 and 15 h(-1), respectively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Al-Meer, S. H.; Amr, M. A.; Helal, A.I.
Because of the very low level of {sup 90}Sr in the environmental soil samples and its determination by beta counting may take several weeks, we developed a procedure for ultra-trace determination of {sup 90}Sr using collision reaction cell-inductively coupled plasma tandem mass spectrometry (CRC-ICP-MS/MS, Agilent 8800). Soil samples were dried at 105 deg. C and then heated in a furnace at 550 deg. C to remove any organics present. 500 g of each soil samples were aliquoted into 2000 ml glass beakers. Each Soils samples were soaked in 2 ppm Sr solution carrier to allow determination of chemical yield. Themore » solid to liquid ratio was 1:1. Finally the soil samples were dried at 105 deg. C. Five hundred milliliters concentrated nitric acid and 250 ml hydrochloric acid volumes were added on 500 g soil samples. The samples were digested on hot plate at 80 deg. C to prevent spraying with continuous manual mixing. The leachate solution was separated. The solids were rinsed with 500 ml deionized water, warmed on a hot plate and the leachate plus previous leachate were filtered and the total volume was reduced to 500 ml by evaporation. Final leachate volume was transferred to a centrifuge tubes. The centrifuge tubes were centrifuged at 3,500 rpm for 10 min. The leachate was transferred to a 1 L beaker and heated on a hot plate to evaporate the leachate to dryness. The reside was re-dissolved in 100 ml of 2% HNO{sub 3} and reduced by evaporation to 10 mL. The solution was measured directly by CRC-ICP-MS/MS by setting the first quadruple analyzer to m/z 90 and introducing oxygen gas into the reaction cell for elimination isobar interference from zirconium-90. The method was validated by measurements of standard reference materials and applied on environmental soil samples. The overall time requirement for the measurement of strontium-90 by CRC-ICP-MS/MS is 2 days, significantly shorter than any radioanalytical protocol currently available. (authors)« less
Raphael, Chenzira D; Zhao, Fang; Hughes, Susan E; Juba, Katherine M
2015-01-01
Levetiracetam is a commonly used antiepileptic medication for tumor-related epilepsy. However, the 100 mL intravenous (IV) infusion volume can be burdensome to imminently dying hospice patients. A reduced infusion volume would improve patient tolerability. The purpose of this study was to evaluate the stability of 1000 mg/25 mL (40 mg/mL) levetiracetam IV solution in sodium chloride 0.9%. We prepared levetiracetam 40 mg/mL IV solution and added it to polyvinyl chloride (PVC) bags, polyolefin bags, and polypropylene syringes. Triplicate samples of each product were stored at refrigeration (2-8°C) and analyzed on days 0, 1, 4, 7, and 14. Samples were subjected to visual inspection, pH measurement, and stability-indicating high-performance liquid chromatography (HPLC) analysis. Over the 2-week storage period, there was no significant change in visual appearance or pH for any of the stability samples. The HPLC results confirmed that all stability samples retained 94.2-101.3% of initial drug concentration and no degradation products or leachable material from the packaging materials were observed. We conclude that levetiracetam 1000 mg/25 mL IV solution in sodium chloride 0.9% is physically and chemically stable for up to 14 days under refrigeration in polypropylene syringes, PVC bags, and polyolefin bags.
27 CFR 21.102 - Caustic soda, liquid.
Code of Federal Regulations, 2014 CFR
2014-04-01
... mark with distilled water at room temperature. Transfer a 25 ml aliquot of the solution to a titration..., and 50 ml of distilled water. Titrate with 0.25 N hydrochloric acid to the disappearance of the pink color. Not less than 25 ml of the hydrochloric acid shall be required to neutralize the sample of...
27 CFR 21.102 - Caustic soda, liquid.
Code of Federal Regulations, 2013 CFR
2013-04-01
... mark with distilled water at room temperature. Transfer a 25 ml aliquot of the solution to a titration..., and 50 ml of distilled water. Titrate with 0.25 N hydrochloric acid to the disappearance of the pink color. Not less than 25 ml of the hydrochloric acid shall be required to neutralize the sample of...
27 CFR 21.102 - Caustic soda, liquid.
Code of Federal Regulations, 2011 CFR
2011-04-01
... mark with distilled water at room temperature. Transfer a 25 ml aliquot of the solution to a titration..., and 50 ml of distilled water. Titrate with 0.25 N hydrochloric acid to the disappearance of the pink color. Not less than 25 ml of the hydrochloric acid shall be required to neutralize the sample of...
27 CFR 21.102 - Caustic soda, liquid.
Code of Federal Regulations, 2010 CFR
2010-04-01
... mark with distilled water at room temperature. Transfer a 25 ml aliquot of the solution to a titration..., and 50 ml of distilled water. Titrate with 0.25 N hydrochloric acid to the disappearance of the pink color. Not less than 25 ml of the hydrochloric acid shall be required to neutralize the sample of...
27 CFR 21.102 - Caustic soda, liquid.
Code of Federal Regulations, 2012 CFR
2012-04-01
... mark with distilled water at room temperature. Transfer a 25 ml aliquot of the solution to a titration..., and 50 ml of distilled water. Titrate with 0.25 N hydrochloric acid to the disappearance of the pink color. Not less than 25 ml of the hydrochloric acid shall be required to neutralize the sample of...
Davarani, Saied Saeed Hosseiny; Pourahadi, Ahmad; Nojavan, Saeed; Banitaba, Mohammad Hossein; Nasiri-Aghdam, Mahnaz
2012-04-13
Electro membrane extraction (EME) as a new microextraction method was applied for extraction of sodium diclofenac (SDF) as an acidic compound from wastewater, urine, bovine milk and plasma samples. Under applied potential of 20 V during the extraction, SDF migrated from a 2.1 mL of sample solution (1mM NaOH), through a supported liquid membrane (SLM), into a 30 μL acceptor solution (10 mM NaOH), exist inside the lumen of the hollow fiber. The negative electrode was placed in the donor solution, and the positive electrode was placed in the acceptor solution. 1-octanol was immobilized in the pores of a porous hollow fiber of polypropylene as SLM. Then the extract was analyzed by means of high-performance liquid chromatography (HPLC) with UV-detection for quantification of SDF. Best results were obtained using a phosphate running electrolyte (10 mM, pH 2.5). The ranges of quantitation for different samples were 8-500 ngmL(-1). Intra- and inter-day RSDs were less than 14.5%. Under the optimized conditions, the preconcentration factors were between 31 and 66 and also the limit of detections (LODs) ranged from 2.7 ng mL(-1) to 5 ng mL(-1) in different samples. This procedure was applied to determine SDF in wastewater, bovine milk, urine and plasma samples (spiked and real samples). Extraction recoveries for different samples were between 44-95% after 5 min of extraction. Copyright © 2012 Elsevier B.V. All rights reserved.
Heydari, Rouhollah; Hosseini, Mohammad; Zarabi, Sanaz
2015-01-01
In this paper, a simple and cost effective method was developed for extraction and pre-concentration of carmine in food samples by using cloud point extraction (CPE) prior to its spectrophotometric determination. Carmine was extracted from aqueous solution using Triton X-100 as extracting solvent. The effects of main parameters such as solution pH, surfactant and salt concentrations, incubation time and temperature were investigated and optimized. Calibration graph was linear in the range of 0.04-5.0 μg mL(-1) of carmine in the initial solution with regression coefficient of 0.9995. The limit of detection (LOD) and limit of quantification were 0.012 and 0.04 μg mL(-1), respectively. Relative standard deviation (RSD) at low concentration level (0.05 μg mL(-1)) of carmine was 4.8% (n=7). Recovery values in different concentration levels were in the range of 93.7-105.8%. The obtained results demonstrate the proposed method can be applied satisfactory to determine the carmine in food samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Albert-García, J R; Calatayud, J Martínez
2008-05-15
The present paper deals with an analytical strategy based on coupling photo-induced chemiluminescence in a multicommutation continuous-flow methodology for the determination of the herbicide benfuresate. The solenoid valve inserted as small segments of the analyte solution was sequentially alternated with segments of the NaOH solution for adjusting the medium for the photodegradation. Both flow rates (sample and medium) were adjusted to required time for photodegradation, 90 s; and then, the resulting solution was also sequentially inserted as segments alternated with segments of the oxidizing solution system, hexacyanoferrate (III) in alkaline medium. The calibration range from 1 microg L(-1) to 95 mg L(-1), resulted in a linear behaviour over the range 1 microg L(-1) to 4 mg L(-1) and fitting the linear equation: I=4555.7x+284.2, correlation coefficient 0.9999. The limit of detection was 0.1 microg L(-1) (n=5, criteria 3 sigma) and the sample throughput was 22 h(-1). The consumption of solutions was very small; per peak were 0.66 mL, 0.16 mL and 0. 32 mL sample, medium and oxidant, respectively. Inter- and intra-day reproducibility resulted in a R.S.D. of 3.9% and 3.4%, respectively. After testing the influence of a large series of potential interferents the method is applied to water samples obtained from different places, human urine and to one formulation.
Huang, Chuixiu; Eibak, Lars Erik Eng; Gjelstad, Astrid; Shen, Xiantao; Trones, Roger; Jensen, Henrik; Pedersen-Bjergaard, Stig
2014-01-24
In this work, a single-well electromembrane extraction (EME) device was developed based on a thin (100μm) and flat porous membrane of polypropylene supporting a liquid membrane. The new EME device was operated with a relatively large acceptor solution volume to promote a high recovery. Using this EME device, exhaustive extraction of the basic drugs quetiapine, citalopram, amitriptyline, methadone and sertraline was investigated from both acidified water samples and human plasma. The volume of acceptor solution, extraction time, and extraction voltage were found to be important factors for obtaining exhaustive extraction. 2-Nitrophenyl octyl ether was selected as the optimal organic solvent for the supported liquid membrane. From spiked acidified water samples (600μl), EME was carried out with 600μl of 20mM HCOOH as acceptor solution for 15min and with an extraction voltage of 250V. Under these conditions, extraction recoveries were in the range 89-112%. From human plasma samples (600μl), EME was carried out with 600μl of 20mM HCOOH as acceptor solution for 30min and with an extraction voltage of 300V. Under these conditions, extraction recoveries were in the range of 83-105%. When combined with LC-MS, the new EME device provided linearity in the range 10-1000ng/ml for all analytes (R(2)>0.990). The repeatability at low (10ng/ml), medium (100ng/ml), and high (1000ng/ml) concentration level for all five analytes were less than 10% (RSD). The limits of quantification (S/N=10) were found to be in the range 0.7-6.4ng/ml. Copyright © 2013 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bibby, R; Guthrie, E
2009-01-30
The instrument has four collection vials that must be filled with ethylene glycol before operation. Each of the four vials should be labeled 1 through 4 and the empty weights recorded. Fill each vial with 80 mL of ethylene glycol and record the weight again. In order for the instrument to operate properly, the collection vials should always have less than 160 mL of total liquid in them. After completing a sample run, remove the collection vials, use a transfer pipette to remove any liquid that might still be on the air paddler, wipe off any condensation from the exteriormore » of the collection vial and record weight. From the instrument, record the ending volume and the time of operation. The solution mixed in the scintillation vial will be 2 ml of a 95% to 50% ethylene glycol to water mixture. To determine the efficiency of counting at all of these concentrations, a series of vials should be set up that consist of 18 ml of Ultima Gold LLT cocktail mixed with standard, regular deionized water and ethylene glycol. The efficiency curve should be counted in the 'Low Level' count mode with the Luminescence Correction ON and the Color Quench Correction ON. Once the tSIE values are determined, chart the cpm against the tSIE numbers and find the best fit for the data. The resulting equation is to be used to converting tSIE values from the collection vials to efficiency. To determine the background cpm value of the ethylene glycol, count a 2 ml sample of ethylene glycol with 18 ml of Ultima Gold for 100 minutes. To determine the total activity of the sample, take two 2 ml aliquots of sample from the first vial and place in separate scintillation vials. Record the weight of each aliquot. Determine the percentage of total sample each aliquot represents by dividing the aliquot weight by the total solution weight from the vial. Also, determine the percentage of ethylene glycol in the sample by dividing the initial solution weight by the final solution weight and multiplying by 100. Add 18 ml of Ultima Gold to each vial and proceed to count for 100 minutes in a 'Low Level' count mode. Before performing a calculation on the dpm value of each aliquot, a subtraction should be made for the background count rate of the ethylene glycol. Based on the background cpm, multiply the background cpm value by the percentage of ethylene glycol in the collection vial. Once the background value is subtracted, calculate the dpm value of the sample based on the tSIE conversion to efficiency. This will produce a dpm value. To convert this to a total activity of the sample, divide the aliquot dpm value by the decimal percentage of total sample the aliquot represents. This gives the total activity of the sample solution. Take the average of both aliquots as a final result. To convert the total activity from the solution in vial one to activity in air, an empirical formula is used to convert activity/gram from vial one to total activity introduced into the system. After calculation the final result for the vial, divide the total by the mass of the sample in vial one. This gives dpm/g (labeled C{sub m}). To convert this to total dpm measured, C = (128.59 * Cm + 10.837)/V Where: C = Tritium concentration in air (dpm/m{sup 3}) C{sub m} = measured tritium concentration from vial 1 (dpm/g) V = Volume of air sampled through instrument (m{sup 3}). C is the final value of tritium concentration in air.« less
A SENSITIVE METHOD FOR THE DETERMINATION OF CARBOXYHAEMOGLOBIN IN A FINGER PRICK SAMPLE OF BLOOD
Commins, B. T.; Lawther, P. J.
1965-01-01
About 0·01 ml. of blood taken from a finger prick is dissolved in 10 ml. of 0·04% ammonia solution. The solution is divided into two halves, and oxygen is bubbled through one half to convert any carboxyhaemoglobin into oxyhaemoglobin. The spectra of the two halves are then compared in a spectrophotometer, and the difference between them is used to estimate the carboxyhaemoglobin content of the blood either graphically or by calculation from a simple formula. Calibration is simple and need only be done once. A sample of blood can be analysed in about 20 minutes, which includes the time to collect the sample. The method is sensitive enough to be used for the analysis of solutions of blood containing less than 1% carboxyhaemoglobin. PMID:14278801
Duff, J.H.; Murphy, F.; Fuller, C.C.; Triska, F.J.
1998-01-01
A new method for collecting pore-water samples in sand and gravel streambeds is presented. We developed a mini drivepoint solution sampling (MINIPOINT) technique to collect pore-water samples at 2.5-cm vertical resolution. The sampler consisted of six small-diameter stainless steel drivepoints arranged in a 10-cm-diameter circular array. In a simple procedure, the sampler was installed in the streambed to preset drivepoint depths of 2.5, 5.0, 7.5, 10.0, 12.5, and 15.0 cm. Sampler performance was evaluated in the Shingobee River, Minnesota, and Pinal Creek, Arizona, by measuring the vertical gradient of chloride concentration in pore water beneath the streambed that was established by the uninterrupted injection to the stream for 3 d. Pore-water samples were withdrawn from all drivepoints simultaneously. In the first evaluation, the vertical chloride gradient was unchanged at withdrawal rates between 0.3 and 4.0 ml min-1 but was disturbed at higher rates. In the second evaluation, up to 70 ml of pore water was withdrawn from each drivepoint at a withdrawal rate of 2.5 ml min-1 without disturbing the vertical chloride gradient. Background concentrations of other solutes were also determined with MINIPOINT sampling. Steep vertical gradients were present for biologically reactive solutes such as DO, NH4/+, NO3/-, and dissolved organic C in the top 20 cm of the streambed. These detailed solute profiles in the hyporheic zone could not have been determined without a method for close interval vertical sampling that does not disturb natural hydrologic mixing between stream water and groundwater.
Zheng, Jian; Yamada, Masatoshi; Wang, Zhongliang; Aono, Tatsuo; Kusakabe, Masashi
2004-06-01
An analytical method for determining (239)Pu and (240)Pu in marine sediment samples, which uses quadrupole ICP-MS, was developed in this work. A simple anion-exchange chromatography system was employed for the separation and purification of Pu from the sample matrix. A sufficient decontamination factor of 1.4 x 10(4) for U, which interferes with the determination of (239)Pu, was achieved. High sensitivity Pu determination was obtained, which led to an extremely low concentration detection limit of approximately 8 fg/ml (0.019 mBq/ml for (239)Pu; 0.071 mBq/ml for (240)Pu) in a sample solution, or an absolute detection limit of 42 fg in a 5 ml sample solution, by using the shield torch technique. Analytical results for the determination of the (239+240)Pu and the (240)Pu/(239)Pu ratio in IAEA 368 (ocean sediment) reference material indicated that the accuracy of the method was satisfactory. The method developed was successfully applied to a study of Pu behavior in the sediments from Sagami Bay, Japan. The observed high (240)Pu/(239)Pu ratio in the sediment core indicated that there was additional Pu input derived from close-in fallout in addition to the global fallout.
Kreienbaum, M A; Page, D P
1986-01-01
The stability of pilocarpine hydrochloride and pilocarpine nitrate ophthalmic solutions stored in hospital pharmacies across the United States was studied. Through a voluntary drug stability program, FDA selected 252 samples (representing 11 manufacturers) from pharmacies representing an adequate cross section of the country. The samples were analyzed for strength, identification, pH, and isopilocarpine and pilocarpic acid impurities. All samples of pilocarpine nitrate met USP requirements. Eight samples of pilocarpine hydrochloride had tablets that exceeded the USP upper limit for strength. All of these samples were in 1- and 2-mL bottles. The amount of isopilocarpine found ranged from 1 to 6.4%, and the amount of pilocarpic acid from 1.5 to 10.1%. Although pilocarpine salts in ophthalmic solution decompose into isopilocarpine and pilocarpic acid under various conditions of storage, an amount of pilocarpine is maintained that is within the compendial limits. However, there is a problem of evaporation from some of the 1- and 2-mL containers in which this product is supplied.
Sun, Shuo; Wang, Ying; Yu, Wenzhi; Zhao, Tianqi; Gao, Shiqian; Kang, Mingqin; Zhang, Yupu; Zhang, Hanqi; Yu, Yong
2011-07-01
The liquid-liquid microextraction (LLME) was developed for extracting sudan dyes from red wine and fruit juice. Room temperature ionic liquid was used as the extraction solvent. The target analytes were determined by high-performance liquid chromatography. The extraction parameters were optimized. The optimal conditions are as follows: volume of [C(6)MIM][PF(6)] 50 μL; the extraction time 10 min; pH value of the sample solution 7.0; NaCl concentration in sample solution 5%. The extraction recoveries for the analytes in red wine and fruit samples are 86.79-108.28 and 68.54-85.66%, whereas RSDs are 1.42-5.12 and 1.43-6.19%, respectively. The limits of detection and quantification were 0.428 and 1.426 ng/mL for sudan I, 0.938 and 3.127 ng/mL for sudan II, 1.334 and 4.445 ng/mL for sudan III, 1.454 and 4.846 ng/mL for sudan IV, respectively. Compared with conventional liquid-liquid extraction (CLLE) and ultrasonic extraction (UE), when LLME was applied, the sample amount was less (LLME: 4 mL; CLLE: 10 mL; UE: 10 mL), the extraction time was shorter (LLME: 15 min; CLLE: 110 min; UE: 50 min) and the extraction solvent amount was less (LLME: 0.05 mL IL; CLLE: 15 mL hexane; UE: 20 mL hexane). The proposed method offers a simple, rapid and efficient sample preparation for determining sudan dyes in red wine and fruit juice samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Karbasi, Mohamad-Hadi; Jahanparast, Babak; Shamsipur, Mojtaba; Hassan, Jalal
2009-10-15
Multielement simultaneous determination of 35 trace elements in environmental samples was carried out by inductively coupled plasma emission spectrometry (ICP-OES) after preconcentration with octadecyl silicagel, modified with aurin tricarboxylic acid (Aluminon). Optimal experimental conditions including pH of sample solution, sample volume, sample and eluent flow rate, type, concentration and volume of eluent and foreign ions effect were investigated and established. Trace element ions in aqueous solution were quantitatively adsorbed onto octadecyl silicagel modified with aurin tricarboxylic acid at pH 8.0 with a flow rate of 11.0 mL min(-1). The adsorbed element ions were eluted with 3-5 mL of 0.5 mol L(-1) HNO(3) at a flow rate of 10.0 mL min(-1) and analyzed by ICP-OES simultaneously. The proposed method has at least preconcentration factor of 100 in water samples, which results high sensitive detection of ultra-trace and trace analysis. The present methodology gave recoveries better than 70% and RSD less than 16%.
Sequential injection spectrophotometric determination of oxybenzone in lipsticks.
Salvador, A; Chisvert, A; Camarasa, A; Pascual-Martí, M C; March, J G
2001-08-01
A sequential injection (SI) procedure for the spectrophotometric determination of oxybenzone in lipsticks is reported. The colorimetric reaction between nickel and oxybenzone was used. SI parameters such as sample solution volume, reagent solution volume, propulsion flow rate and reaction coil length were studied. The limit of detection was 3 microg ml(-1). The sensitivity was 0.0108+/-0.0002 ml microg(-1). The relative standard deviations of the results were between 6 and 12%. The real concentrations of samples and the values obtained by HPLC were comparable. Microwave sample pre-treatment allowed the extraction of oxybenzone with ethanol, thus avoiding the use of toxic organic solvents. Ethanol was also used as carrier in the SI system. Seventy-two injections per hour can be performed, which means a sample frequency of 24 h(-1) if three replicates are measured for each sample.
Zhang, Yanlin; Adeloju, Samuel B
2008-08-15
A simple and robust flow injection system which permits low sample and reagent consumption is described for rapid and reliable hydride generation atomic absorption spectrometric determination of selenium, arsenic and bismuth. The system, which composed of one peristaltic pump and one four channel solenoid valve, used water as the carrier streams for both sample and NaBH(4) solution. Rapid off-line pre-reduction of the analytes was achieved by using hydroxylamine hydrochloride for selenium and a mixture of potassium iodide and ascorbic acid for arsenic and bismuth. Transition metal interference was eliminated with the addition of thiourea and EDTA into the NaBH(4) solution and significant sensitivity enhancement was observed for selenium in the presence of thiourea in the reductant solution. Under optimised conditions, the method achieved detection limits of 0.2 ng mL(-1) for Se, 0.5 ng mL(-1) for As and 0.3 ng mL(-1) for Bi. The method was very reproducible, achieving relative standard deviations of 6.3% for Se, 3.6% for As and 4.7% for Bi, and has a sample throughput of 360 h(-1). Successful application of the method to the quantification of selenium, arsenic and bismuth in a certified reference river sediment sample is reported.
Impact of laminar flow velocity of different acids on enamel calcium loss.
Attin, T; Becker, K; Wiegand, A; Tauböck, T T; Wegehaupt, F J
2013-03-01
The aim of the study was to evaluate the impact of flow velocity under laminar flow conditions of different acidic solutions on enamel erosion. A total of 240 bovine enamel specimens were prepared and allocated to 30 groups (n = 8 each). Samples of 18 groups were superfused in a flow chamber system with laminar flow behavior using 1 ml of citric acid or hydrochloric acid (HCl) of pH 2.0, 2.6 or 3.0. Flow rates in the sample chamber were adjusted to 10, 60 or 100 μl/min. To simulate turbulent flow behavior, samples of six groups were immersed in 1 ml of the respective solution, which was vortexed (15 min, 600 rpm). For simulating non-agitated conditions, specimens of the remaining six groups were immersed in 1 ml of the respective solution without stirring. Calcium in the solutions, released from the enamel samples, was determined using Arsenazo III method. For acidic solutions of pH 2.6 and 3.0, erosive potential of citric acid was equivalent to that of HCl at a flow of 100 μl/min. The same observation was made for the samples subjected to turbulent conditions at pH 3. At all other conditions, citric acid induced a significantly higher calcium loss than HCl. It is concluded that under slow laminar flow conditions, flow rate variations lead to higher erosive impact of citric acid compared to hydrochloric acid at pH 2.0, but not at pH ≥ 2.6 and increasing laminar flow or turbulent conditions. Erosive enamel dissolution under laminar flow conditions is a complex issue influenced by flow rate and acidic substrate.
NASA Astrophysics Data System (ADS)
Kassem, Mohammed A.; Amin, Alaa S.
2015-02-01
A new method to estimate rhodium in different samples at trace levels had been developed. Rhodium was complexed with 5-(4‧-nitro-2‧,6‧-dichlorophenylazo)-6-hydroxypyrimidine-2,4-dione (NDPHPD) as a complexing agent in an aqueous medium and concentrated by using Triton X-114 as a surfactant. The investigated rhodium complex was preconcentrated with cloud point extraction process using the nonionic surfactant Triton X-114 to extract rhodium complex from aqueous solutions at pH 4.75. After the phase separation at 50 °C, the surfactant-rich phase was heated again at 100 °C to remove water after decantation and the remaining phase was dissolved using 0.5 mL of acetonitrile. Under optimum conditions, the calibration curve was linear for the concentration range of 0.5-75 ng mL-1 and the detection limit was 0.15 ng mL-1 of the original solution. The enhancement factor of 500 was achieved for 250 mL samples containing the analyte and relative standard deviations were ⩽1.50%. The method was found to be highly selective, fairly sensitive, simple, rapid and economical and safely applied for rhodium determination in different complex materials such as synthetic mixture of alloys and environmental water samples.
Micellar electrokinetic chromatographic determination of triazine herbicides in water samples.
Li, Zhi; Zhang, Shuaihua; Yin, Xiaofang; Wang, Chun; Wang, Zhi
2014-09-01
Dispersive liquid-liquid microextraction combined with online sweeping preconcentration in micellar electrokinetic chromatography was developed for the simultaneous determination of five triazine herbicides (atrazine, simazine, propazine, prometon and simetryn) in water samples. Several experimental parameters affecting the extraction efficiencies such as the type and volume of both the extraction and dispersive solvents, the addition of salt to sample solution, the extraction time and the pH of the sample solution were investigated. Under optimum conditions, the linearity of the method was good in the range from 0.33 to 20 ng mL(-1) for simazine, propazine, atrazine and simetryn, and from 0.17 to 20 ng mL(-1) for prometon, respectively. The sensitivity enrichment factors were in the range from 1750 to 2100, depending on the compound. The limit of detection (S/N = 3) ranged from 0.05 to 0.10 ng mL(-1). The developed method was successfully applied to the analysis of the five triazines in river, ground and well waters. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Interaction of Sr-90 with site candidate soil for demonstration disposal facility at Serpong
NASA Astrophysics Data System (ADS)
Setiawan, Budi; Mila, Oktri; Safni
2014-03-01
Interaction of radiostrontium (Sr-90) with site candidate soil for demonstration disposal facility to be constructed in the near future at Serpong has been done. This activity is to anticipate the interim storage facility at Serpong nuclear area becomes full off condition, and show to the public how radioactive waste can be well managed with the existing technology. To ensure that the location is save, a reliability study of site candidate soil becomes very importance to be conducted through some experiments consisted some affected parameters such as contact time, effect of ionic strength, and effect of Sr+ ion in solution. Radiostrontium was used as a tracer on the experiments and has role as radionuclide reference in low-level radioactive waste due to its long half-live and it's easy to associate with organism in nature. So, interaction of radiostrontium and soil samples from site becomes important to be studied. Experiment was performed in batch method, and soil sample-solution containing radionuclide was mixed in a 20 ml of PE vial. Ratio of solid: liquid was 10-2 g/ml. Objective of the experiment is to collect the specific characteristics data of radionuclide sorption onto soil from site candidate. Distribution coefficient value was used as indicator where the amount of initial and final activities of radiostrontium in solution was compared. Result showed that equilibrium condition was reached after contact time 10 days with Kd values ranged from 1600-2350 ml/g. Increased in ionic strength in solution made decreased of Kd value into soil sample due to competition of background salt and radiostrontium into soil samples, and increased in Sr ion in solution caused decreased of Kd value in soil sample due to limitation of sorption capacity in soil samples. Fast condition in saturated of metal ion into soil samples was reached due to a simple reaction was occurred.
Tabani, Hadi; Fakhari, Ali Reza; Shahsavani, Abolfath; Behbahani, Mohammad; Salarian, Mani; Bagheri, Akbar; Nojavan, Saeed
2013-07-26
Combination of different extraction methods is an interesting and debatable work in the field of sample preparation. In the current study, for the first time, solid phase extraction combined with electro membrane extraction (SPE-EME) was developed for ultra-preconcentration and determination of chlorophenoxy acid herbicides in environmental samples using capillary electrophoresis (CE). In the mentioned method, first, a 100mL of chlorophenoxy acid herbicides (2-methyl-4-chlorophenoxyacetic acid (MCPA), 2-(2,4-dichlorophenoxy) propanoic acid (2,4-DP) and 2-(4-chloro-2-methylphenoxy) propanoic acid (MCPP)) was passed through a column of graphene oxide as a solid phase, and then the adsorbed herbicides were eluted by 4.0mL of 8% acetic acid (HOAC) in methanol. Then, the elution solvent was evaporated and the herbicides residue was dissolved in 4.0mL of double distilled water (pH 9.0). Afterwards, the herbicides in 4.0mL of the aqueous solution were transferred to an EME glass vial. In the EME step, the herbicides were extracted from the sample solution into the basic acceptor solution (pH 13.0) under electrical potential, which was held inside the lumen of the fiber with 1-octanol as the supported liquid membrane (SLM). Under the optimized conditions, high enrichment factors were obtained in the range of 1950-2000. The limits of quantification (LOQs) and method detection limits (MDLs) were obtained in the range of 1.0-1.5 and 0.3-0.5ngmL(-1), respectively. Finally, the performance of the present method was evaluated for extraction and determination of chlorophenoxy acid herbicides in environmental samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Miralles, Pablo; Bellver, Raquel; Chisvert, Alberto; Salvador, Amparo
2016-03-01
Vortex-assisted emulsification semimicroextraction is proposed as a one-step solution-extraction procedure for sample preparation in cosmetic products. The procedure allows rapid preparation based on dispersion of the sample in a mixture of 1 mL of n-hexane and 0.5 mL of ethanol, followed by the addition of 0.5 mL of water and centrifugation to obtain two separated phases. This procedure provides good sample clean-up with minimum dilution and is very useful for the determination of ingredients with restricted concentrations, such as bronopol. The procedure was applied to the determination of bronopol by liquid chromatography with UV detection. The best chromatographic separation was obtained by using a C18 column set at 40 °C and performing a stepwise elution with a mixture of ethanol/aqueous 1 % acetic acid solution as mobile phase pumped at 0.5 mL min(-1). The detection wavelength was set at 250 nm and the total run time required was 12 min. The method was successfully applied to 18 commercial cosmetic samples including creams, shampoos, and bath gels. Good recoveries and repeatability were obtained, with a limit of detection of 0.9 μg mL(-1), which makes the method suitable for the analytical control of cosmetic products. Moreover, it could be considered environmentally friendly, because water, ethanol, and only a low volume of n-hexane are used as solvents.
Tulipan, Rachel J; Phillips, Heidi; Garrett, Laura D; Dirikolu, Levent; Mitchell, Mark A
2017-05-01
OBJECTIVE To characterize long-term elution of platinum from carboplatin-impregnated calcium sulfate hemihydrate (CI-CSH) beads in vitro by comparing 2 distinct sample collection methods designed to mimic 2 in vivo environments. SAMPLES 162 CI-CSH beads containing 4.6 mg of carboplatin (2.4 mg of platinum/bead). PROCEDURES For method 1, which mimicked an in vivo environment with rapid and complete fluid exchange, each of 3 plastic 10-mL conical tubes contained 3 CI-CSH beads and 5 mL of PBS solution. Eluent samples were obtained by evacuation of all fluid at 1, 2, 3, 6, 9, and 12 hours and 1, 2, 3, 6, 9, 12, 15, 18, 22, 26, and 30 days. Five milliliters of fresh PBS solution was then added to each tube. For method 2, which mimicked an in vivo environment with no fluid exchange, each of 51 tubes (ie, 3 tubes/17 sample collection times) contained 3 CI-CSH beads and 5 mL of PBS solution. Eluent samples were obtained from the assigned tubes for each time point. All samples were analyzed for platinum content by inductively coupled plasma-mass spectrometry. RESULTS Platinum was released from CI-CSH beads for 22 to 30 days. Significant differences were found in platinum concentration and percentage of platinum eluted from CI-CSH beads over time for each method. Platinum concentrations and elution percentages in method 2 samples were significantly higher than those of method 1 samples, except for the first hour measurements. CONCLUSIONS AND CLINICAL RELEVANCE Sample collection methods 1 and 2 may provide estimates of the minimum and maximum platinum release, respectively, from CI-CSH beads in vivo.
1993-12-01
Stopper the flask and shake vigorously. The mixture was titrated with 0.003 N sodium lauryl sulfate drcpwise. The endpoint was the first definite...100 g sodium sulfate and 1000 mL distilled water, pill0) and three drops of 0.1% bracu 1henol blue indicator to 50 ML of sample in a 250 mL flask...Product QDS (Syncide Plus) (1) was determined by a bromcphenol blue nethod (7). Add 25 mL of chloroform, 25 mL salt buffer solution (7 g sodium carbonate
Particulate and microbial contamination in in-use admixed intravenous infusions.
Yorioka, Katsuhiro; Oie, Shigeharu; Oomaki, Masafumi; Imamura, Akihisa; Kamiya, Akira
2006-11-01
We compared particulate and microbial contamination in residual solutions of peripheral intravenous admixtures after the termination of drip infusion between intravenous fluids admixed with glass ampoule drugs and those admixed with pre-filled syringe drugs. The mean number of particles>or=1.3 microm in diameter per 1 ml of residual solution was 758.4 for fluids (n=60) admixed with potassium chloride in a glass ampoule (20 ml volume), 158.6 for fluids (n=63) admixed with potassium chloride in a pre-filled syringe (20 ml volume), 736.5 for fluids (n=66) admixed with sodium chloride in a glass ampoule (20 ml volume), 179.2 for fluids (n=15) admixed with sodium chloride in a pre-filled syringe (20 ml volume), 1884.5 in fluids (n=30) admixed with dobutamine hydrochloride in 3 glass ampoules (5 ml volume), and 178.9 (n=10) in diluted dobutamine hydrochloride in pre-filled syringes (50 ml volume: For these samples alone, particulate and microbial contamination were evaluated in sealed products.) Thus, for potassium chloride or sodium chloride for injection, the number of particles>or=1.3 microm in diameter in the residual intravenous solution was significantly higher for fluids admixed with glass ampoule drugs than for those admixed with pre-filled syringe drugs (p<0.0001). For dobutamine hydrochloride for injection, the number of particles>or=1.3 microm in diameter in the residual intravenous solution was estimated to be higher for fluids admixed with its glass ampoule drug than for those admixed with its pre-filled syringe drug. Observation of the residual solutions of fluids admixed with potassium chloride, sodium chloride, or dobutamine hydrochloride in glass ampoules using an electron microscope with an X-ray analyzer showed glass fragments in each residual solution. Therefore, for the prevention of glass particle contamination in peripheral intravenous admixtures, the use of pre-filled syringe drugs may a useful method. No microbial contamination was observed in any of the residual solutions of 5 types of admixture.
NASA Astrophysics Data System (ADS)
Khajeh, Mostafa; Pedersen-Bjergaard, Stig; Barkhordar, Afsaneh; Bohlooli, Mousa
2015-02-01
In this study, wheat stem was used for electromembrane extraction (EME) for the first time. The EME technique involved the use of a wheat stem whose channel was filled with 3 M HCl, immersed in 10 mL of an aqueous sample solution. Thorium migrated from aqueous samples, through a thin layer of 1-octanol and 5%v/v Di-(2-ethylhexyl) phosphate (DEHP) immobilized in the pores of a porous stem, and into an acceptor phase solution present inside the lumen of the stem. The pH of donor and acceptor phases, extraction time, voltage, and stirring speed were optimized. At the optimum conditions, an enrichment factor of 50 and a limit of detection of 0.29 ng mL-1 was obtained for thorium. The developed procedure was then applied to the extraction and determination of thorium in water samples and in reference material.
Kennedy Space Center Fixation Tube (KFT)
NASA Technical Reports Server (NTRS)
Richards, Stephanie E.; Levine, Howard G.; Romero, Vergel
2016-01-01
Experiments performed on the International Space Station (ISS) frequently require the experimental organisms to be preserved until they can be returned to earth for analysis in the appropriate laboratory facility. The Kennedy Fixation Tube (KFT) was developed to allow astronauts to apply fixative, chemical compounds that are often toxic, to biological samples without the use of a glovebox while maintaining three levels of containment (Fig. 1). KFTs have been used over 200 times on-orbit with no leaks of chemical fixative. The KFT is composed of the following elements: a polycarbonate main tube where the fixative is loaded preflight, the sample tube where the plant or other biological specimens is placed during operations, the expansion plug, actuator, and base plug that provides fixative containment (Fig. 2). The main tube is pre-filled with 25 mL of fixative solution prior to flight. When actuated, the specimen contained within the sample tube is immersed with approximately 22 mL (+/- 2 mL) of the fixative solution. The KFT has been demonstrated to maintain its containment at ambient temperatures, 4degC refrigeration and -100 C freezing conditions.
An iPhone-based digital image colorimeter for detecting tetracycline in milk.
Masawat, Prinya; Harfield, Antony; Namwong, Anan
2015-10-01
An iPhone-based digital image colorimeter (DIC) was fabricated as a portable tool for monitoring tetracycline (TC) in bovine milk. An application named ColorConc was developed for the iPhone that utilizes an image matching algorithm to determine the TC concentration in a solution. The color values; red (R), green (G), blue (B), hue (H), saturation (S), brightness (V), and gray (Gr) were measured from each pictures of the TC standard solutions. TC solution extracted from milk samples using solid phase extraction (SPE) was captured and the concentration was predicted by comparing color values with those collected in a database. The amount of TC could be determined in the concentration range of 0.5-10 μg mL(-1). The proposed DIC-iPhone is able to provide a limit of detection (LOD) of 0.5 μg mL(-1) and limit of quantitation (LOQ) of 1.5 μg mL(-1). The enrichment factor was 70 and color of the extracted milk sample was a strong yellow solution after SPE. Therefore, the SPE-DIC-iPhone could be used for the assay of TC residues in milk at the concentration lower than LOD and LOQ of the proposed technique. Copyright © 2015 Elsevier Ltd. All rights reserved.
Kramer, Axel; Lemanski, Sandra; Demond, Kathleen; Assadian, Ojan
2012-01-01
The hygienic-microbiological control of 6 dental units being in use for the past 16 years revealed a significantly increased microbial contamination of their cooling water system. In order to comply with the requirements of the drinking water directive ("Trinkwasserverordnung"), the commercially available production system ActiDes, producing on-site ActiDes-Blue which is based on hypochlorous acid (HOCl) and generated by anodic oxidation, was investigated. Water samples from the 6 contaminated dental units were examined for the total number of colony forming units (cfu), contamination with molds, L. pneumophila and P. aeruginosa. The control period for the total colony count was 4 weeks (8 samples/unit). The subsequent application phase of the ActiDes-Blue procedure was 6 months (31 samples/unit). Additionally, the redox potential and the pH value were measured.Futhermore, the decontamination agent CARELA HYDRO-DES, a two component agent based on H(2)O(2) with the addition of a mixture of sodium hydrogen sulphate and sulphuric acid in an aqueous solution effective at 0.1% and higher, was applied in a unit that had been put out of service for a month before. Before application, the system was first filled with a 5% solution of the alkaline pre-cleaning agent CARELA Solvent for bacterial slime; the system was left with this solution for 1 h. The pre-cleaning agent was then completely displaced from the system with tap water and a decontaminating solution of 5% CARELA HYDRO-DES and left in place for 1 h. Drinking water quality level was reached only twice during the control phase. The average values of the dental units ranged between 3,633 CFU/ml and 29,417 c/ml. During the application phase, drinking water level could be achieved in 11 water samples. In another 6 water samples a total colony count of <150 cfu/ml was reached. The average values for the dental units' total colony count ranged between 529 cfu/ml and 87,450 cfu/ml. No significant differences between the control phase and the action phase could be demonstrated. During the control phase, contamination of the water samples with a mold was noticed so that examinations for molds were carried out beyond the scope of the drinking water directive. For this parameter as well, no significant differences between the phases of the study could be shown.The Legionella load of the dental units was low. L. pneumophila were yielded in only 4 out of 130 water samples. During the control phase, twice colony counts at 50 cfu/1,000 ml and 110 cfu/1,000 ml were measured. During the action phase, counts with Legionella spp. could be measured at 5 cfu/1,000 ml for one unit only. Also, with 1-10 cfu/100 ml, the P. aeruginosa contamination was low. During the application phase, it ranged between 0-7 cfu/100 ml.Redox potential and pH value showed a slight decrease during the application phase.Before treatment with CARELA Solvent and CARELA HYDRO-DES, the initial contamination of the total count of bacterial colonies was 1,432 cfu/ml at 22°C and 846 cfu/ml at 36°C as well as >1,000 cfu/100 ml for molds. 1 h after the decontamination, no bacteria and molds could be detected in 1,000 ml of tap water. Despite the fact that the unit was not used any longer, after 7 d the bacterial colony count was 3 cfu/ml at 22°C and 2 cfu/ml at 36°C while molds could not be detected. Even after a rest time of 14 d only 167 cfu/ml or 42 cfu/ml could be yielded. Molds were further not cultivable. A material damage could not be observed. Pertaining to the ActiDes technology's effectiveness, it has to be pointed out that the dental units investigated were those used for dental students' teaching and therefore were clearly less frequently used than clinically used units in a dental practice. This resulted in distinctly longer stagnation periods which favored formation of biofilms. In summary, the ActiDes technology and ActiDes-Blue showed not to be sufficiently effective for the sanitation of contaminated water reservoirs in dental units under aggravated conditions of repeated and longer periods of non-use in connection with longer water stagnation periods. In comparison, the biofilm was sustainably eliminated through the combined application of CARELA(®) Solvent for Bacterial Slime with subsequent decontamination using CARELA(®) HYDRO-DES.
Determination of simazine in water samples by HPLC after preconcentration with diatomaceous earth.
Katsumata, Hideyuki; Fujii, Aya; Kaneco, Satoshi; Suzuki, Tohru; Ohta, Kiyohisa
2005-01-15
A sensitive and selective batch adsorption method is proposed for the preconcentration and determination of simazine. Simazine was preconcentrated on diatomaceous earth as an adsorbent and then determined by high-performance liquid chromatography (HPLC). Several parameters on the recovery of the analyte were investigated. The experimental results showed that it was possible to obtain quantitative analysis when the solution pH was 2 using 100mL of validation solution containing 1.5mug of simazine and 5mL of ethanol as an eluent. Recovery of simazine was 89.0 +/- 1.6% with a relative standard deviation for seven determinations of 1.5% under optimum conditions. The maximum preconcentration factor was 100 for simazine when 500mL of sample solution volume was used. The linear range of calibration curve was 1-200ngmL(-1) with a correlation coefficient of 0.996 and the detection limit (3S/N) was 0.3ngmL(-1). The capacity of the adsorbent was also examined and found to be 1.1mgg(-1) for simazine. The proposed method was successfully applied to the determination of simazine in river water with high precision and accuracy.
Novel approaches to analysis by flow injection gradient titration.
Wójtowicz, Marzena; Kozak, Joanna; Kościelniak, Paweł
2007-09-26
Two novel procedures for flow injection gradient titration with the use of a single stock standard solution are proposed. In the multi-point single-line (MP-SL) method the calibration graph is constructed on the basis of a set of standard solutions, which are generated in a standard reservoir and subsequently injected into the titrant. According to the single-point multi-line (SP-ML) procedure the standard solution and a sample are injected into the titrant stream from four loops of different capacities, hence four calibration graphs are able to be constructed and the analytical result is calculated on the basis of a generalized slope of these graphs. Both approaches have been tested on the example of spectrophotometric acid-base titration of hydrochloric and acetic acids with using bromothymol blue and phenolphthalein as indicators, respectively, and sodium hydroxide as a titrant. Under optimized experimental conditions the analytical results of precision less than 1.8 and 2.5% (RSD) and of accuracy less than 3.0 and 5.4% (relative error (RE)) were obtained for MP-SL and SP-ML procedures, respectively, in ranges of 0.0031-0.0631 mol L(-1) for samples of hydrochloric acid and of 0.1680-1.7600 mol L(-1) for samples of acetic acid. The feasibility of both methods was illustrated by applying them to the total acidity determination in vinegar samples with precision lower than 0.5 and 2.9% (RSD) for MP-SL and SP-ML procedures, respectively.
NASA Astrophysics Data System (ADS)
Kamakura, Nao; Inui, Tetsuo; Kitano, Masaru; Nakamura, Toshihiro
A new method for the separate determination of Chromium(III) (Cr(III)), Chromium(VI) (Cr(VI)), and Cr(III) acetylacetonate (Cr(acac)3) in water was developed using a cation-exchange extraction disk (CED) and an anion-exchange extraction disk (AED) combined with metal furnace atomic absorption spectrometry (MFAAS). A 100-mL water sample was adjusted to pH 5.6 and passed through the CED placed on the AED. Cr(acac)3 and Cr(III) were adsorbed on the CED, and Cr(VI) was adsorbed on the AED. The adsorbed Cr(acac)3 was eluted with 50 mL of carbon tetrachloride, followed by the elution of Cr(III) with 50 mL of 3 mol L- 1 nitric acid. Cr(VI) was eluted with 50 mL of 3 mol L- 1 nitric acid. The chemical species of Cr eluted from the CED with carbon tetrachloride was identified as Cr(acac)3 using infrared spectroscopy. The eluate of Cr(acac)3 was diluted to 100 mL with carbon tetrachloride, and those of Cr(III) and Cr(VI) were diluted to 100 mL with deionized water. All of the solutions were subsequently analyzed by MFAAS. The calibration curve for the Cr(acac)3 aqueous solutions exhibited good linearity in the range of 0.1 to 1 ng. The detection limit of Cr, which corresponded to three times the standard deviation (n = 10) of the blank values, was 20 pg. The recovery test for Cr(III), Cr(VI), and Cr(acac)3 exhibited desirable results (96.0%-107%) when 5 μg of each species (50 μg L- 1) was added to 100 mL water samples (i.e., tap water, rainwater, and bottled drinking water). In a humic acid solution, Cr(acac)3 was quantitatively recovered (103%), but Cr(III) and Cr(VI) exhibited poor recoveries (i.e., 84.8% and 78.4%, respectively).
Eiden, Céline; Philibert, Laurent; Bekhtari, Khedidja; Poujol, Sylvain; Malosse, Francoise; Pinguet, Frédéric
2009-11-01
The physicochemical stability of extemporaneous dilutions of oxaliplatin in 5% dextrose injection stored in polyvinyl chloride (PVC), polypropylene, and polyethylene infusion bags was studied. Oxaliplatin 100 mg/20 mL concentrated solution was diluted in 100 mL of 5% dextrose injection in PVC, polypropylene, and polyethylene infusion bags to produce nominal oxaliplatin concentrations of 0.2 and 1.3 mg/mL. The filled bags were stored for 14 days at 20 degrees C and protected from light, at 20 degrees C under normal fluorescent light, and at 4 degrees C. A 1-mL sample was removed from each bag at time 0 and at 24, 48, 72, 120, 168, and 336 hours. The samples were visually inspected for color and clarity, and the pH values of the solutions were measured. High-performance liquid chromatography was used to assay oxaliplatin concentration. Bacterial contamination was assessed on study day 14 after incubation in trypticase soy solution for three days at 37 degrees C. Solutions of oxaliplatin 0.2 and 1.3 mg/mL in 5% dextrose injection were stable in the three container types for at least 14 days at both 4 degrees C and 20 degrees C without regard to light exposure. No color change was detected during the storage period, and pH values remained stable. No microbial contamination was detected in any samples over the study period. Oxaliplatin solutions diluted in 5% dextrose injection to 0.2 and 1.3 mg/mL were stable in PVC and PVC-free infusion bags for at least 14 days at both 4 degrees C and 20 degrees C without regard to light exposure.
Li, Shi-Weng; Song, Hong-Ping; Leng, Yan
2014-01-01
Lovastatin, a hypocholesterolemic drug, is produced by submerged fermentation of Aspergillus terreus Thom (Trichocomaceae). High performance liquid chromatography is usually used to determine lovastatin in samples of the fermentation broth. However, this method is inconvenient and costly, especially in the context of high-throughput sample analysis. A direct and simple dual-wavelength ultraviolet spectrophotometric method for quantifying lovastatin in the fermentation broth of A. terreus was developed. A. terreus Z15-7 was used for all experiments. The liquid fermentation was conducted at 30 °C in a rotary shaker at 150 rpm for 15 d. Silica gel and neutral alumina column chromatography were used for the separation and purification of lovastatin from the fermentation broth. The limits of detection of lovastatin were 0.320 μg/ml in the lovastatin standard solution and 0.490 μg/ml in the fermentation broth sample and the limits of quantification of lovastatin were 1.265 μg/ml in the lovastatin standard solution and 3.955 μg/ml in the fermentation broth sample. The amounts of lovastatin in the fermentation broth ranged from 876.614 to 911.967 μg/ml, with relative standard deviations from 1.203 to 1.709%. The mean recoveries of lovastatin using silica gel and neutral alumina column chromatography were 84.2 ± 0.82 and 87.2 ± 0.21%, respectively. Dual-wavelength UV spectrophotometry is a rapid, sensitive, accurate, and convenient method for quantifying lovastatin in fermentation broth. Neutral alumina column chromatography is more efficient than silica gel column chromatography for the purification and determination lovastatin using the developed dual-wavelength UV spectrophotometry method.
Hall, Wendy C E; Jolly, Donald T; Hrazdil, Jiri; Galbraith, John C; Greacen, Maria; Clanachan, Alexander S
2003-01-01
To evaluate the ability of the EmulSiv filter (EF) to remove extrinsic microbial contaminants from propofol. Aliquots of Staphylococcus aureus (S. aureus), Candida albicans (C. albicans), Klebsiella pneumoniae (K. pneumoniae), Moraxella osloensis (M. osloensis), Enterobacter agglomerans (E. agglomerans), Escherichia coli (E. coli), Serratia marcescens (S. marcescens), Moraxella catarrhalis (M. catarrhalis), Haemophilus influenzae (H. influenzae) and Campylobacter jejuni (C. jejuni) were inoculated into vials containing 20 mL of sterile propofol. The unfiltered inoculated propofol solutions served as controls. Ten millilitres and 20 mL samples of the inoculated propofol were filtered through the EF. All solutions were then subplated onto three culture plates using a precision 1 micro L calibrated platinum loop and incubated. The number of colony forming units (CFU) were counted. Data were analyzed using a one-sample t test, and a P value of less than 0.05 was selected as the level of statistical significance. The EF was able to completely remove CFU of S. aureus, C. albicans, K. pneumoniae, M. osloensis, E. agglomerans, E. coli, S. marcescens, and M. catarrhalis (P < 0.05). A small number of H. influenzae CFU were able to evade filtration in both the 10 mL and 20 mL samples. C. jejuni CFU were able to evade filtration in only the 10 mL sample. The EF removes the majority of microbial contaminates from propofol with the exception of H. influenzae and C. jejuni. Although the EF is capable of removing most of the microbial contamination produced by H. influenzae and C. jejuni, a few CFU are capable of evading filtration. Consequently, even the use of a filter capable of removing microbial contaminants is not a substitute for meticulous aseptic technique and prompt administration when propofol is used.
Ochiai, Nobuo; Sasamoto, Kikuo; Tsunokawa, Jun; Hoffmann, Andreas; Okanoya, Kazunori; MacNamara, Kevin
2015-11-20
An extension of multi-volatile method (MVM) technology using the combination of a standard dynamic headspace (DHS) configuration, and a modified DHS configuration incorporating an additional vacuum module, was developed for milliliter injection volume of aqueous sample with full sample evaporation. A prior step involved investigation of water management by weighing of the water residue in the adsorbent trap. The extended MVM for 1 mL aqueous sample consists of five different DHS method parameter sets including choice of the replaceable adsorbent trap. An initial two DHS sampling sets at 25°C with the standard DHS configuration using a carbon-based adsorbent trap target very volatile solutes with high vapor pressure (>10 kPa) and volatile solutes with moderate vapor pressure (1-10 kPa). Subsequent three DHS sampling sets at 80°C with the modified DHS configuration using a Tenax TA trap target solutes with low vapor pressure (<1 kPa) and/or hydrophilic characteristics. After the five sequential DHS samplings using the same HS vial, the five traps are sequentially desorbed with thermal desorption in reverse order of the DHS sampling and the desorbed compounds are trapped and concentrated in a programmed temperature vaporizing (PTV) inlet and subsequently analyzed in a single GC-MS run. Recoveries of 21 test aroma compounds in 1 mL water for each separate DHS sampling and the combined MVM procedure were evaluated as a function of vapor pressure in the range of 0.000088-120 kPa. The MVM procedure provided high recoveries (>88%) for 17 test aroma compounds and moderate recoveries (44-71%) for 4 test compounds. The method showed good linearity (r(2)>0.9913) and high sensitivity (limit of detection: 0.1-0.5 ng mL(-1)) even with MS scan mode. The improved sensitivity of the method was demonstrated with analysis of a wide variety of aroma compounds in brewed green tea. Compared to the original 100 μL MVM procedure, this extension to 1 mL MVM allowed detection of nearly twice the number of aroma compounds, including 18 potent aroma compounds from top-note to base-note (e.g. 2,3-butanedione, coumarin, furaneol, guaiacol, cis-3-hexenol, linalool, maltol, methional, 3-methyl butanal, 2,3,5-trimethyl pyrazine, and vanillin). Sensitivity for 23 compounds improved by a factor of 3.4-15 under 1 mL MVM conditions. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kim, Yong-Hyun; Kim, Ki-Hyun
2015-11-01
An analytical technique was developed for the quantitation of volatile organic compounds (VOC) in three different forms of electronic cigarette (EC): solution, vapor, and aerosol. Through the application of the mass change tracking (MCT) approach, the consumed amount of the solution was measured to track the conversion of targets between the different phases. The concentration of aerosol plus vapor (A&V) decreased exponentially (559 to 129 g m-3) with increasing puff velocity (0.05 to 1 L min-1). A strong correlation existed between sampling volume and consumed solution mass (R2 = 0.9972 ± 0.0021 (n = 4)). In the EC solution, acetic acid was considerably high (25.8 μg mL-1), along with trace quantities of some VOCs (methyl ethyl ketone, toluene, propionic acid, and i-butyric acid: 0.24 ± 0.15 μg mL-1 (n = 4)). In the aerosol samples, many VOCs (n-butyraldehyde, n-butyl acetate, benzene, xylene, styrene, n-valeric acid, and n-hexanoic acid) were newly produced (138 ± 250 μg m-3). In general, the solution-to-aerosol (S/A) conversion was significant: e.g., 1,540% for i-butyric acid. The emission rates of all targets computed based on their mass in aerosol/ consumed solution (ng mL-1) were from 30.1 (p-xylene) to 398 (methyl ethyl ketone), while those of carboxyls were much higher from 166 (acetic acid) to 5,850 (i-butyric acid).
A reflectance flow-through thionine sol-gel sensor for the determination of Se(IV).
Carvalhido, Joana A E; Almeida, Agostinho A; Araújo, Alberto N; Montenegro, Maria C B S M
2010-01-01
In this work, a reversible sensor to assess the total Se(IV) content in samples is described. Pre-activated glass slides were spin-coated with 100 microL of a 20-h aged sol-gel mixture of 1 mL of tetramethoxysilane, 305 microL of 50 mmol L(-1) HCl and 2.0 mg of thionine. The flow-cell consisted of one of those slides as a window, and was filled with beads of a polystyrene anionic exchange resin to retain Se(IV) in the form of selenite ions. A reflectance transduction scheme at a wavelength of 596 nm was adopted. The cell was coupled to a multicommutation flow system where a programmed volume of a sample solution and 373 microL of 0.4 mmol L(-1) iodide in a 1.6 mol L(-1) HCl solution were sequentially inserted into the cell. The iodine produced from the reaction of retained Se(IV) with iodide bleached the blue color of thionine. Considering a sample volume of 2.30 mL, with which the preconcentration step was minimized, a linear dynamic working range between 1.5 to 20 microg mL(-1) and a detection limit of 0.29 microg mL(-1) were obtained. The sensor enabled us to perform approximately 200 assays, and provided results similar to those of electrothermal atomic absorption spectrometry.
Stability of levothyroxine sodium 0.4 microg/mL in 0.9% sodium chloride injection.
Stadalman, Kelli A; Kelner, Michael J; Box, Kevin; Dominguez, Alex; Rigby, Joseph F
2009-12-01
Intravenous levothyroxine therapy decreases vasopressor requirements and prevents cardiovascular collapse in hemodynamically unstable patients eligible for organ donation. The stability of levothyroxine when used in this manner is unknown. To determine the stability of levothyroxine solution for intravenous use at a concentration of 0.4 microg/mL diluted in 0.9% sodium chloride. Triplicate sample sets were prepared by reconstituting levothyroxine 200 microg for injection with 5 mL of 0.9% sodium chloride with further dilution in 500 mL of 0.9% sodium chloride. One sample set was protected from light and the other was left unprotected. Both sample sets were stored at room temperature, and samples from each were analyzed for initial concentration and 4, 8, 12, and 24 hours later. Levothyroxine sodium 0.4 microg/mL in 500 mL 0.9% sodium chloride is stable for 24 hours at room temperature when protected from light.
Raad, Issam; Hachem, Ray; Tcholakian, Robert K.; Sherertz, Robert
2002-01-01
To determine the efficacy of antibiotic catheter lock solution in preventing catheter-related infections, silicone catheters were tunneled and inserted into the jugular veins of 18 rabbits. The catheters were challenged with an intraluminal injection of 105 CFU of slime-producing Staphylococcus epidermidis in 0.1 ml of water. The catheters were maintained on heparin (100 IU/ml) flush for the first 3 days. On day 3, quantitative blood samples for culture were obtained from the catheters and ear veins, which documented catheter-related bacteremia, and the rabbits were randomized to have their catheters flushed as follows: five animals were continued on heparin (100 IU/ml), five animals received vancomycin (3 mg/ml) with heparin (100 IU/ml), and eight animals received 3 mg of minocycline per ml with 30 mg of EDTA per ml (M-EDTA). All animals were killed at day 7. Blood, catheters, jugular veins, and heart valves were cultured quantitatively. Animals maintained on heparin developed catheter-related colonization, bacteremia, septic phlebitis, and endocarditis. Vancomycin-heparin partially prevented catheter colonization, bacteremia, and phlebitis (P = 0.2). M-EDTA completely prevented catheter colonization, catheter-related bacteremia, and phlebitis in all of the animals (P < 0.01). Tricuspid endocarditis was equally prevented by vancomycin-heparin and M-EDTA (P ≤ 0.06). In conclusion, the M-EDTA catheter flush solution was highly efficacious in preventing catheter-related colonization, bacteremia, septic phlebitis, and endocarditis in rabbits. PMID:11796338
Effects of fluid, electrolyte and substrate ingestion on endurance capacity.
Maughan, R J; Fenn, C E; Leiper, J B
1989-01-01
The availability of carbohydrate (CHO) as a substrate for the exercising muscles is known to be a limiting factor in the performance of prolonged cycle exercise, and provision of exogenous CHO in the form of glucose can increase endurance capacity. The present study examined the effects of ingestion of fluids and of CHO in different forms on exercise performance. Six male volunteers exercised to exhaustion on a cycle ergometer at a workload which required approximately 70% of Vo2max. After one preliminary trial, subjects performed this exercise test on six occasions, one week apart. Immediately before exercise, and at 10-min intervals throughout, subjects ingested 100 ml of one of the following: control (no drink), water, glucose syrup, fructose syrup, glucose-fructose syrup or a dilute glucose-electrolyte solution. Each of the syrup solutions contained approximately 36 g CHO per 100 ml; the isotonic glucose-electrolyte solution contained 4 g glucose per 100 ml. A randomised Latin square order of administration of trials was employed. Expired air samples for determination of Vo2, respiratory exchange ratio and rate of CHO oxidation were collected at 15-min intervals. Venous blood samples were obtained before and after exercise. Subjects drinking the isotonic glucose-electrolyte solution exercised longer (90.8 (12.4) min, mean (SEM] than on the control test (70.2 (8.3) min; p less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)
NASA Astrophysics Data System (ADS)
Koao, Lehlohonolo F.; Motloung, Setumo V.; Motaung, Tshwafo E.; Kebede, Mesfin A.
2018-04-01
LiMn2O4 (LMO) powders were prepared by modified chemical bath deposition (CBD) method by varying ammonium hydroxide solution (AHS). The volume of the AHS was varied from 5 to 120 mL in order to determine the optimum volume that is needed for preparation of LMO powders. The effect of AHS volume on the structure, morphology, and electrochemical properties of LMO powders was investigated. The X-ray diffraction (XRD) patterns of the LMO powders correspond to the cubic spinel LMO phase. It was found that the XRD peaks increased in intensity with increasing volume of the AHS up to 20 mL. The estimated average grain sizes calculated using the XRD patterns were found to be in the order of 66 ± 1 nm. It was observed that the estimated average grain sizes increased up to 20 mL of AHS. The scanning electron microscopy (SEM) results revealed that the AHS volume does not influence the surface morphology of the prepared nano-powders. Elemental energy dispersive (EDS) analysis mapping conducted on the samples revealed homogeneous distribution of Mn and O for the sample synthesized with 120 mL of AHS. The UV-Vis spectra showed a red shift with an increase in AHS up 20 mL. The cyclic voltammetry and galvanostatic charge/discharge cycle testing confirmed that 20 mL of AHS has superior lithium ion kinetics and electrochemical performance.
Ramesh, A; Balasubramanian, M
1999-01-01
A simple and rapid method involving solid phase extraction and liquid chromatography for the determination of azadirachtin-A and -B, nimbin and salannin at nanogram levels in neem oil samples is presented. The neem oil samples are defatted and the compounds of interest extracted by mixing the sample with hexane and passing the hexane solution through a graphitised carbon black column. After washing the column with 2 ml of hexane, azadirachtin-A and -B, nimbin and salannin are eluted with 5 ml of acetonitrile and quantified using HPLC with UV detection. The recoveries of azadirachtin-A and -B, nimbin and salannin in fortified oil samples were 97.4-104.7%. The upper limit of quantification is up to 100 micrograms ml-1 without any additional clean-up and with little interference from lipids during the analysis by HPLC. The method was successfully applied to various neem oil samples collected from different locations in India.
Zakrzewski, Robert; Ciesielski, Witold
2005-09-25
The reaction between iodine and azide ions induced by thiopental was utilized as a postcolumn reaction for chromatographic determination of thiopental. The method is based on the separation of thiopental on an Nova-Pak CN HP column with an acetonitrile-aqueous solution of sodium azide as a mobile phase, followed by spectrophotometric measurement of the residual iodine (lambda=350 nm) from the postcolumn iodine-azide reaction induced by thiopental after mixing an iodine solution containing iodide ions with the column effluent containing azide ions and thiopental. Chromatograms obtained for thiopental showed negative peaks as a result of the decrease in background absorbance. The detection limit (defined as S/N=3) was 20 nM (0.4 pmol injected amount) for thiopental. Calibration graphs, plotted as peak area versus concentrations, were linear from 40 nM. The elaborated method was applied to determine thiopental in urine samples. The detection limit (defined as S/N=3) was 0.025 nmol/ml urine. Calibration graphs, plotted as peak area versus concentrations, were linear from 0.05 nmol/ml urine. Authentic urine samples were analyzed, thiopental was determined at nmol/ml urine level.
Sample preparation and UHPLC-FD analysis of pteridines in human urine.
Tomšíková, H; Solich, P; Nováková, L
2014-07-01
Elevated levels of pteridines can indicate the activation of cellular immune system by certain diseases. No work dealing with the simultaneous determination of urinary neopterin, biopterin and their reduced forms has been published. Therefore, a new SPE-UHPLC-FD method for the analysis of these compounds has been developed. The main emphasis was put on the stability of dihydroforms during the sample processing and storage. As a stabilizing agent, dithiothreitol, at various concentrations, and various pH values (3.8-9.8) of working solutions were tested. Chromatographic separation was performed under HILIC isocratic conditions on BEH Amide column. The method was linear for the calibration standard solutions in the range of 10-10,000 ng/ml (dihydroforms) and 0.5-1000 ng/ml (oxidized forms), and for real samples in the range of 25-1000 ng/ml (dihydroforms) and 1-100 ng/ml (oxidized forms). The development of a new SPE sample preparation method was carried out on different types of sorbents (based on a mixed-mode cation exchange, porous graphitic carbon and a polymer comprising hydrophilic and hydrophobic components). Final validation was performed on a MCAX SPE column. Method accuracy ranged from 76.9 to 121.9%. The intra- and inter-day precision did not exceed 10.7%. The method provided high sensitivity for the use in routine clinical measurements of urine (LLOQ 1 ng/ml for oxidized forms and 25 ng/ml for dihydroforms). Average concentrations of biopterin, neopterin, and dihydrobiopterin found in urine of healthy persons were related to the mol of creatinine (66.8, 142.3, and 257.3 μmol/mol of creatinine, respectively) which corresponded to the literature data. The concentration of dihydroneopterin obtained using our method was 98.8 μmol/mol of creatinine. Copyright © 2014 Elsevier B.V. All rights reserved.
Rapid colorimetric assay for gentamicin injection.
Tarbutton, P
1987-01-01
A rapid colorimetric method for determining gentamicin concentration in commercial preparations of gentamicin sulfate injection was developed. Methods currently available for measuring gentamicin concentration via its colored complex with cupric ions in alkaline solution were modified to reduce the time required for a single analysis. The alkaline copper tartrate (ACT) reagent solution was prepared such that each milliliter contained 100 mumol cupric sulfate, 210 mumol potassium sodium tartrate, and 1.25 mmol sodium hydroxide. The assay involves mixing 0.3 mL gentamicin sulfate injection 40 mg/mL (of gentamicin), 1.0 mL ACT reagent, and 0.7 mL water; the absorbance of the resulting solution at 560 nm was used to calculate the gentamicin concentration in the sample. For injections containing 10 mg/mL of gentamicin, the amount of the injection was increased to 0.5 mL and water decreased to 0.5 mL. The concentration of gentamicin in samples representing 11 lots of gentamicin sulfate injection 40 mg/mL and 8 lots of gentamicin sulfate injection 10 mg/mL was determined. The specificity, reproducibility, and accuracy of the assay were assessed. The colored complex was stable for at least two hours. Gentamicin concentration ranged from 93.7 to 108% and from 95 to 109% of the stated label value of the 40 mg/mL and the 10 mg/mL injections, respectively. No components of the preservative system present in the injections interfered with the assay. Since other aminoglycosides produced a colored complex, the assay is not specific for gentamicin. The assay was accurate and reproducible over the range of 4-20 mg of gentamicin. This rapid and accurate assay can be easily applied in the hospital pharmacy setting.
Baytak, Sıtkı; Arslan, Zikri
2015-01-01
This study presents a simple, robust and environmentally friendly solid phase preconcentration procedure for multielement determination by inductively coupled plasma optical emission spectrometry (ICP-OES) using diphenylcarbazone (DPC) impregnated TiO2 nanopowder (n-TiO2). DPC was successfully impregnated onto n-TiO2 in colloidal solution. A number of elements, including Co(II), Cr(III), Cu(II), Fe(III), Mn(II) and Zn(II) were quantitatively preconcentrated from aqueous solutions between pH 8 and 8.5 at a flow rate of 2 mL min−1, and then eluted with 2 mL of 5% (v/v) HNO3. A mini-column packed with 0.12 g DPC impregnated n-TiO2 retained all elements quantitatively from up to 250 mL multielement solution (2.5 μg per analyte) affording an enrichment factor of 125. The limits of detection (LOD) for preconcentration of 50 mL blank solutions (n = 12) were 0.28, 0.15, 0.25, 0.22, 0.12, and 0.10 μg L−1 for Co, Cr, Cu, Fe, Mn, and Zn, respectively. The relative standard deviation (RSD) for five replicate determinations was 0.8, 3.4, 2.6, 2.2, 1.2 and 3.3% for Co, Cr, Cu, Fe, Mn and Zn, respectively, at 5 μg L−1 level. The method was validated with analysis of Freshwater (SRM 1643e) and Lobster hepatopancreas (TORT-2) certified reference materials, and then applied to the determination of the elements from tap water and lake water samples by ICP-OES. PMID:26236403
ANALYTICAL METHOD FOR THE ABSORPTIOMETRIC DETERMINATION OF BORON IN AMMONIA SOLUTION
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1962-01-01
ABS>A weighed sample is evaporated to dryness with caustic soda solution on a water bath. The residue is dissolved by addlng a solution of curcumin in acetic acid. After adding a mixture of H/sub 2/SO/sub 4/ and acetic acid, the solution is allowed to stand at room temperature for 15 minutes. The solution is then diluted to 100 ml with ethanol, and a portion is filtered and measured absorptiometrically on the residue as the curcumin complex. (P.C.H.)
Ensom, Mary H H; Decarie, Diane; Leung, Karen; Montgomery, Carolyne
2009-03-01
To evaluate the stability of mixtures of hydromorphone and ketamine in 0.9% sodium chloride (normal saline [NS]) after storage for up to 7 days at room temperature (25°C). The stability of 3 standard mixtures of hydromorphone and ketamine (hydromorphone 0.2 mg/mL + ketamine 0.2 mg/mL, hydromorphone 0.2 mg/mL + ketamine 0.6 mg/mL, and hydromorphone 0.2 mg/mL + ketamine 1.0 mg/mL) in NS was studied. Portions of each mixture were transferred to 3 brown glass bottles (100 mL), 3 plastic syringes (50 mL), and 3 IV bags (50 mL), which were then stored at room temperature (25°C). Physical characteristics, including pH, colour, and precipitation, were evaluated daily. Three 1.5-mL samples were collected from each bottle, syringe, and IV bag at baseline, at 24, 48, and 72 hours, and on day 7. Samples were analyzed in triplicate by a stability-indicating high-performance liquid chromatography method. Solutions were considered stable if they maintained 90% of the initial concentration of each drug. Samples from syringes and IV bags were subjected to standard sterility testing by incubation for 5 days in an enriched culture media. No notable changes in pH or colour were observed, and no precipitation occurred in any of the solutions. All formulations maintained more than 90% of the initial concentration of each drug on day 7. No bacterial growth was observed in any of the samples tested. Mixtures of hydromorphone and ketamine were stable for up 7 days at 25°C, and the sterility of the preparations was maintained. Because stability alone does not guarantee efficacy, it is recommended that clinical studies be conducted to evaluate the pharmacokinetics and pharmacodynamics of these formulations.
Amin, Alaa S
2010-12-01
A highly sensitive, selective and rapid method for the determination μg L(-1) level of Au(III) based on the rapid reaction of Au(III) with 2,3-dichloro-6-(3-carboxy-2-hydroxy-1-naphthylazo)quinoxaline (DCHNAQ) and the solid phase extraction of the colored complex with a reversed phase polymer-based C18 cartridge have been developed. The DCHNAQ reacted with Au(III) to form a violet complex of a molar ratio 3:1 [DCHNAQ to Au(III)] in the presence of 5.0 M of phosphoric acid solution and Triton X-100 medium. This complex was enriched by the solid phase extraction with a polymer-based C18 cartridge. The enrichment factor of 100 was achieved. The molar absorptivity of the complex is 2.73×10(5) l mol(-1) cm(-1) at 633 nm in the measured solution. The system obeys Beer's law in the range of 0.02-1.30 μg ml(-1), whereas the optimum concentration ranges obtained from Ringbom plot was 0.08-1.24 μg ml(-1). The relative standard deviation for ten replicates sample of 0.6 μg ml(-1) level is 1.28%. The detection and quantification limits, are 6.1 and 19.5 ng ml(-1) in the original sample. This method was applied to the determination of gold in water, jewel and ore samples with good results comparing to the GFAAS method. Copyright © 2010 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Coedo, A. G.; Dorado, T.; Padilla, I.; Maibusch, R.; Kuss, H.-M.
2000-02-01
A commercial atomic absorption graphite furnace (AAGF), with a self-made adapter and valve system, was used as a slurry sampling cell for electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS). The system was applied to the determination of As, Sn, Sb, Se, Te, Bi, Cd, V, Ti and Mo in steelmaking flue dusts. Experimental conditions with respect to ETV and ICP-MS operating parameters were optimized. Compared to aqueous solutions, slurry samples were found to present better analyte transport. Microgram amounts of Rh were used to reduce the difference in analyte response in sensitivity for aqueous solutions of the tested analytes. No such increasing effect was observed for slurry samples and aqueous standards. An added quantity of Rh acting as modifier/carrier resulted in an increase for the same analytes in matrix-slurry solutions, even the addition of an extra Rh quantity has resulted in a decrease in the signals. The effect of Triton X-100 (used as a dispersant agent) on analyte intensity and precision was also studied. External calibration from aqueous standards spiked with 100 μg ml -1 Rh was performed to quantified 0.010 g/100 ml slurry samples. Results are presented for a certified reference electrical arc furnace flue dust (EAF): CRM-876-1 (Bureau of Analysis Samples Ltd., Cleveland, UK), a reference sample of coke ashes X-3705 (from AG der Dillinger Hüttenwerke, Germany), and a representative sample of EAF flue dust from a Spanish steelmaking company (CENIM-1). For the two reference materials an acceptable agreement with certificate values was achieved, and the results for the CENIM sample matched with those obtained from conventional nebulization solution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahn, H.J.; Choi, K.C.; Choi, K.S.
2013-07-01
As a destructive quantification method of {sup 3}H in low and intermediate level radwastes, bomb oxidation, sample oxidation, and wet oxidation methods have been introduced. These methods have some merits and demerits in the radiochemical separation of {sup 3}H radionuclides. That is, since the bomb oxidation and sample oxidation methods are techniques using heating at high temperature, the separation methods of the radionuclides are relatively simple. However, since {sup 3}H radionuclide has a property of being diffused deeply into the inside of metals, {sup 3}H which is distributed on the surface of the metals can only be extracted if themore » methods are applied. As an another separation method, the wet oxidation method makes {sup 3}H oxidized with an acidic solution, and extracted completely to an oxidized HTO compound. However, incomplete oxidized {sup 3}H compounds, which are produced by reactions of acidic solutions and metallic radwastes, can be released into the air. Thus, in this study, a wet oxidation method to extract and quantify the {sup 3}H radionuclide from metallic radwastes was established. In particular, a complete extraction method and complete oxidation method of incomplete chemical compounds of {sup 3}H using a Pt catalyst were studied. The radioactivity of {sup 3}H in metallic radwastes is extracted and measured using a wet oxidation method and liquid scintillation counter. Considering the surface dose rate of the sample, the appropriate size of the sample was determined and weighed, and a mixture of oxidants was added to a 200 ml round flask with 3 tubes. The flask was quickly connected to the distilling apparatus. 20 mL of 16 wt% H{sub 2}SO{sub 4} was given into the 200-ml round flask through a dropping funnel while under stirring and refluxing. After dropping, the temperature of the mixture was raised to 96 deg. C and the sample was leached and oxidized by refluxing for 3 hours. At that time, the incomplete oxidized {sup 3}H compounds were completely oxidized using the Pt catalysts and produced a stable HTO compound. After that, about a 20 ml solution was distilled in the separation apparatus, and the distillate was mixed with an ultimagold LLT as a cocktail solution. The solution in the vial was left standing for at least 24 hours. The radioactivity of {sup 3}H was counted directly using a liquid scintillation analyzer (Packard, 2500 TR/AB, Alpha and Beta Liquid Scintillation Analyzer). (authors)« less
Kim, Dianne H; Stark, Walter J; O'Brien, Terrence P; Dick, James D
2005-11-01
To measure the achievable perioperative aqueous concentration of the commercially available topically administered fourth generation fluoroquinolones, moxifloxacin 0.5% ophthalmic solution, and gatifloxacin 0.3% ophthalmic solution, and to correlate this concentration with the agents' biological efficacy in the aqueous humor of patients undergoing routine cataract surgery. Prospective, randomized, parallel, double-masked, clinical trial. Fifty patients undergoing cataract extraction. Patients (n = 25) were given perioperative topical moxifloxacin 0.5% or topical gatifloxacin 0.3% (n = 25). One drop of antibiotic was administered every 10 minutes for 4 doses beginning 1 hour prior to surgery. Aqueous humor was sampled via paracentesis and antibiotic concentrations were determined using validated high performance liquid chromatography (HPLC) procedures. Dilution analyses were performed to determine the biological efficacy of the agents in the aqueous against Staphylococcus epidermidis, the most common cause of postcataract endophthalmitis. Aqueous humor antibiotic concentrations were measured using HPLC and microdilution bioassay techniques. Biological activity was measured as minimal inhibitory dilution and minimal bactericidal dilution. Aqueous humor concentrations for moxifloxacin via HPLC analysis were 1.80 (+/-1.21) microg/ml, whereas those for gatifloxacin were 0.48 (+/-0.34) microg/ml. This 3.8-fold difference in aqueous humor antibiotic concentrations was statistically significant (P = 0.00003). Similarly, the biological dilution analysis of the aqueous humor samples showed that moxifloxacin attained an estimated activity of 2.1 microg/ml, whereas the gatifloxacin activity was approximately 0.4 mug/ml, which represented a 4.9-fold difference. This study demonstrated that after topically administered perioperative antibiotics with cataract surgery, moxifloxacin 0.5% ophthalmic solution achieved a statistically significantly higher concentration in aqueous humor compared with gatifloxacin (P = 0.00003). Results from the broth dilution analysis showed that moxifloxacin 0.5% was biologically more active against S. epidermidis than gatifloxacin 0.3% in aqueous humor after topical application. There were no adverse events reported, and incision wounds healed quickly and as expected.
Kojima, T; Ishii, A; Watanabe-Suzuki, K; Kurihara, R; Seno, H; Kumazawa, T; Suzuki, O; Katsumata, Y
2001-10-05
Four general anaesthetics, sevoflurane, isoflurane, enflurane and halothane, in human whole blood, have been found measurable with very high sensitivity by capillary gas chromatography-flame ionization detection (GC-FID) with cryogenic oven trapping upon injection of headspace (HS) vapor sample. To a 7-ml vial, containing 0.48 ml of distilled water and 20 microl of internal standard solution (5 microg), a 0.5-ml of whole blood sample spiked with or without anaesthetics, was added, and the mixture was heated at 55 degrees C for 15 min. A measure of 10 ml HS vapor was injected into the GC in the splitless mode at -40 degrees C oven temperature, which was programmed up to 250 degrees C. All four peaks were clearly separated; no impurity peaks were found among their peaks. Their extraction efficiencies were about 10%. The calibration curves showed good linearity in the range of 0.5-20 microg/ml; their detection limits were 10-100 ng/ml, which are almost comparable to those by previous reports. The coefficients of intra-day and day-to-day variations were 6.5-9.8 and 7.3-17.2%, respectively. Isoflurane or enflurane was also measured from whole blood samples in which three volunteers inhaled each compound.
Dogan, Alev Aksoy; Adiloglu, Ali K; Onal, Suleyman; Cetin, Emel Sesli; Polat, Esra; Uskun, Ersin; Koksal, Fatih
2008-11-01
To evaluate the efficacy of common antiseptic mouth rinses and octenidine dihydrochloride (OCT). The antibacterial activities of antiseptics against total and cariogenic bacteria (Streptococcus mutans and Lactobacillus species) in saliva were studied in vitro and in vivo. After unstimulated saliva was collected, one of the mouth rinse solutions was applied for 30seconds. Saliva samples were collected 15, 30, 60, and 120min later and evaluated for their bacterial count. OCT had a significantly greater inhibitory effect on the studied bacteria than 0.2% chlorhexidine gluconate (CHX) and 7.5% polyvinylpyrrolidone-iodine complex (PVP-I) from 15min to 120min following the application (p<0.01). The antiseptic efficacy of 0.2% CHX on total bacteria and Lactobacillus species was very similar to the efficacy observed with 7.5% PVP-I mouth solution from 15min up to 120min. Streptococcus mutans was completely inhibited by 0.15mg/ml PVP-I, 0.5mg/ml CHX, and 0.1mg/ml OCT concentrations, while Streptococcus salivarius was inhibited by 0.15mg/ml PVP-I, 2mg/ml CHX, and 0.8mg/ml OCT concentrations. Lactococcus lactis subspecies lactis was inhibited with 0.00313mg/ml OCT, 30mg/ml PVP-I, and 0.0063mg/ml CHX concentrations. OCT compared favorably with CHX and PVP-I in its antibacterial effects, both in vitro and in vivo (p<0.01).
Li, Mengqing; Forest, Jean-Marc; Coursol, Christian; Leclair, Grégoire
2011-09-01
The stability of cyclosporine diluted to 0.2 or 2.5 mg/mL with 0.9% sodium chloride injection or 5% dextrose injection and stored in polypropylene-polyolefin containers or polypropylene syringes was evaluated. Intravenous cyclosporine solutions (0.2 and 2.5 mg/mL) were aseptically prepared and transferred to 250-mL polypropylene-polyolefin bags or 60-mL polypropylene syringes. Chemical stability was measured using a stability-indicating high-performance liquid chromatography (HPLC) assay. Physical stability was assessed by visual inspection and a dynamic light scattering (DLS) method. After 14 days, HPLC assay showed that the samples of i.v. cyclosporine stored in polypropylene-polyolefin bags remained chemically stable (>98% of initial amount remaining); the physical stability of the samples was confirmed by DLS and visual inspection. The samples stored in polypropylene syringes were found to contain an impurity (attributed to leaching of a syringe component by the solution) that could be detected by HPLC after 1 day; on further investigation, no leaching was detected when the syringes were exposed to undiluted i.v. cyclosporine 50 mg/mL for 10 minutes. Samples of i.v. cyclosporine solutions of 0.2 and 2.5 mg/mL diluted in 0.9% sodium chloride injection or 5% dextrose injection and stored at 25 °C in polypropylene-polyolefin bags were physically and chemically stable for at least 14 days. When stored in polypropylene syringes, the samples were contaminated by an impurity within 1 day; however, the short-term (i.e., ≤10 minutes) use of the syringes for the preparation and transfer of i.v. cyclosporine solution is considered safe.
Extraction and Determination of Cyproheptadine in Human Urine by DLLME-HPLC Method.
Maham, Mehdi; Kiarostami, Vahid; Waqif-Husain, Syed; Abroomand-Azar, Parviz; Tehrani, Mohammad Saber; Khoeini Sharifabadi, Malihe; Afrouzi, Hossein; Shapouri, Mahmoudreza; Karami-Osboo, Rouhollah
2013-01-01
Novel dispersive liquid-liquid microextraction (DLLME), coupled with high performance liquid chromatography with photodiode array detection (HPLC-DAD) has been applied for the extraction and determination of cyproheptadine (CPH), an antihistamine, in human urine samples. In this method, 0.6 mL of acetonitrile (disperser solvent) containing 30 μL of carbon tetrachloride (extraction solvent) was rapidly injected by a syringe into 5 mL urine sample. After centrifugation, the sedimented phase containing enriched analyte was dissolved in acetonitrile and an aliquot of this solution injected into the HPLC system for analysis. Development of DLLME procedure includes optimization of some important parameters such as kind and volume of extraction and disperser solvent, pH and salt addition. The proposed method has good linearity in the range of 0.02-4.5 μg mL(-1) and low detection limit (13.1 ng mL(-1)). The repeatability of the method, expressed as relative standard deviation was 4.9% (n = 3). This method has also been applied to the analysis of real urine samples with satisfactory relative recoveries in the range of 91.6-101.0%.
Filtrates & Residues: A Convenient, Low-Cost Method for Determining Sulfate in Acid Rain.
ERIC Educational Resources Information Center
Johns, Nicholas; Longstaff, Stephen J.
1987-01-01
Describes efforts in devising a method for determining sulfate quickly and accurately from rainwater samples. Explains the design and operation of the apparatus and identifies the solutions for the testing. (ML)
Yang, Xia; Guo, Bao-Lin; Hu, Hong-Yu; Huang, Wen-Hua; Qiao, He-Ping; Fan, Sheng-Ci; Guan, Zha-Gen
2013-09-01
A Cleanert Alumina-N-SPE column (0.5 g/6 mL) chromatograpy with 5 mL of chloroform-methanol (7: 3) as eluent, instead of aluminum oxide column (100-200 mesh, 5 g, 1 cm) chromatograpy eluted successively with chloroform and the chloroform-methanol (7:3) (20 mL each), was applied to enrich matrine and oxymatrine in Sophora flavescens. Also, the optimization of the HPLC determination conditions with acetonitrile-ethanol absolute-3% phosphoric acid solution (84: 6: 10) as mobile phase, instead of acetonitrile-ethanol absolute -3% Phosphoric acid solution (80: 10: 10) recorded in Chinese Pharmacopoeia 2010 Edition, was more suitable for determination of matrine and oxymatrine in S. flavescens. This method has advantage of reducing sample handling time and solvent volume and increasing the accuracy and feasibility, which can simplify the procedure for determination of matrine and oxymatrine in S. flavescens.
Hor, M M; Chan, S Y; Yow, K L; Lim, L Y; Chan, E
1997-01-01
To study the stability of admixtures of pethidine and metoclopramide in aqueous solution, 0.9% sodium chloride and 5% dextrose preparations. Aqueous mixtures of 1 ml of 50 mg/ml pethidine with 2ml of 5 mg/ml metoclopramide were prepared in plastic syringes, while the 0.9% sodium chloride and 5% dextrose admixtures, each containing 7.35 mg/ml of pethidine and 0.15 mg/ml of metoclopramide, were prepared in infusion bags. The preparations were stored under light and dark conditions at 32 degrees C for 48 h. Samples were collected at 0, 0.5, 1, 2, 4, 6, 8, 24, 32 and 48 h. A high-performance liquid chromatographic method was developed to separate and quantify both drugs. All preparations were found to be physically and chemically stable for at least 48h, as concentration changes were within 10% of their initial level, with no development of haze, precipitate or colour. Light appeared to have a negligible effect. Although pH changes were observed, they were inconsistent and were within the ranges in which the drugs are expected to remain stable. Pethidine and metoclopramide admixtures can, therefore, on stability grounds be used for the concomitant management of pain, nausea and vomiting.
Hagiwara, Kenta; Inui, Tetsuo; Koike, Yuya; Nakamura, Toshihiro
2013-01-01
A simple method of graphite-furnace atomic-absorption spectrometry (GFAAS) after solid-phase extraction (SPE) was developed for the determination of diphenylarsinic acid (DPAA), phenylarsonic acid (PAA), and inorganic arsenic (iAs) in drinking water. This method involves the simultaneous collection of DPAA, PAA, and iAs using three stacked SPE disks, i.e., an Empore SDB-XD disk (the upper layer), an activated carbon disk (the middle layer), and a Cation-SR disk loaded with Zr and Ca (ZrCa-CED; the lower layer). A 200-mL aqueous sample was adjusted to pH 3 with nitric acid and passed through the SPE disks at a flow rate of 15 mL min(-1), to concentrate DPAA on the SDB-XD disk, PAA on the activated carbon disk, and iAs on the ZrCa-CED. The As compounds were eluted from the disks with 10 mL of ethanol containing 0.5 mol L(-1) ammonia solution for DPAA, 20 mL of 1 mol L(-1) ammonia solution for PAA, and 20 mL of 6 mol L(-1) hydrochloric acid for iAs. The eluates of DPAA, PAA, and iAs were diluted to 20, 25, and 25 mL, respectively, with deionized water, and then analyzed by GFAAS. The detection limits of As (three-times the standard deviation (n = 3) of the blank values) were 0.13 and 0.16 μg L(-1) at enrichment factors of 10 and 8, respectively, using a 200-mL water sample. Spike tests with 2 μg (10 μg L(-1)) of DPAA, PAA, and iAs in 200 mL of tap water and bottled drinking water showed good recoveries (96.1-103.8%).
Accuracy of water displacement hand volumetry using an ethanol and water mixture.
Hargens, Alan R; Kim, Jong-Moon; Cao, Peihong
2014-02-01
The traditional water displacement method for measuring limb volume is improved by adding ethanol to water. Four solutions were tested (pure water, 0.5% ethanol, 3% ethanol, and 6% ethanol) to determine the most accurate method when measuring the volume of a known object. The 3% and 6% ethanol solutions significantly reduced (P < 0.001) the mean standard deviation of 10 measurements of a known sphere (390.1 +/- 0.25 mi) from 2.27 ml with pure water to 0.9 ml using the 3% alcohol solution and to 0.6 using 6% ethanol solution (the mean coefficients of variation were reduced from 0.59% for water to 0.22% for 3% ethanol and 0.16% for 6% ethanol). The spheres' volume measured with pure water, 0.5% ethanol solution, 3% ethanol solution, and 6% ethanol solution was 383.2 +/- 2.27 ml, 384.4 +/- 1.9 ml, 389.4 +/- 0.9 ml, and 390.2 +/- 0.6 ml, respectively. Using the 3% and 6% ethanol solutions to measure hand volume blindly in 10 volunteers significantly reduced the mean coefficient of variation for hand volumetry from 0.91% for water to 0.52% for the 3% ethanol solution (P < 0.05) and to 0.46% for the 6% ethanol solution (P < 0.05). The mean standard deviation from all 10 subjects decreased from 4.2 ml for water to 2.3 ml for 3% ethanol solution and 2.1 ml for the 6% solution. These findings document that the accuracy and reproducibility of hand volume measurements are improved by small additions of ethanol, most likely by reducing surface tension of water.
Pires, Adriana Elias; Honda, Neli Kiko; Cardoso, Cláudia Andréa Lima
2004-10-29
A method for sample preparation and analysis by high performance liquid chromatography with UV detection (HPLC-UV) has been developed for routine analysis of psoralen and bergapten, photosensitizing compounds, in oral solutions of phytomedicines employed in Brazil for some illnesses. The linearity, accuracy, the inter- and intra-day precision of the procedure were evaluated. Calibration curves for psoralen and bergapten were linear in the range of 1.0-600.0 microg ml(-1) and 1.0-400.0 microg ml(-1) respectively. The recoveries of the psoralens in the oral solutions analysed were 94.43-99.97%. The percentage coefficient of variation (CV) of the quantitative analysis of the psoralens in the products analysis was within 5%. In inter-equipment study was employed gas chromatography-flame ionization (CG-FID) detection.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 5 ml of this solution to a 250 ml glass-stoppered flask containing 25 ml distilled water. Add 25 ml of a freshly prepared 1 percent sodium bisulfite solution. Prepare a blank omitting the acetaldol solution. Place the flasks in a dark place away from excessive heat or cold and allow to stand six hours...
Code of Federal Regulations, 2013 CFR
2013-04-01
... 5 ml of this solution to a 250 ml glass-stoppered flask containing 25 ml distilled water. Add 25 ml of a freshly prepared 1 percent sodium bisulfite solution. Prepare a blank omitting the acetaldol solution. Place the flasks in a dark place away from excessive heat or cold and allow to stand six hours...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 5 ml of this solution to a 250 ml glass-stoppered flask containing 25 ml distilled water. Add 25 ml of a freshly prepared 1 percent sodium bisulfite solution. Prepare a blank omitting the acetaldol solution. Place the flasks in a dark place away from excessive heat or cold and allow to stand six hours...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 5 ml of this solution to a 250 ml glass-stoppered flask containing 25 ml distilled water. Add 25 ml of a freshly prepared 1 percent sodium bisulfite solution. Prepare a blank omitting the acetaldol solution. Place the flasks in a dark place away from excessive heat or cold and allow to stand six hours...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 5 ml of this solution to a 250 ml glass-stoppered flask containing 25 ml distilled water. Add 25 ml of a freshly prepared 1 percent sodium bisulfite solution. Prepare a blank omitting the acetaldol solution. Place the flasks in a dark place away from excessive heat or cold and allow to stand six hours...
Cytotoxicity of selected medicinal plants used in Mt. Frere District, South Africa.
Mnengi, Dorris; Kappo, Abidemi; Kambizi, Learnmore; Nakin, Motebang
2014-01-01
In South African traditional medicine, some are plants known to combat pediatric diseases and are commonly used by traditional healers. The aim was to evaluate cytotoxicity effects of plants. The ground plant material was exhaustively extracted using methanol, acetone and water separately for 72 hrs. These organic solvents were removed from filtrates using a rotavapour. Stock solutions were prepared at 40 mg/ml Dimethyl sulfoxide (DMSO) and test solutions were transferred into vials and 10 brine shrimps introduced in each. The number of dead shrimps was counted to ascertain toxicity. Ten A. salina nauplii (larva) were transferred into each sample vial and filtered brine solution was added to make 5 ml. The nauplii were counted macroscopically in the stem of the pipette against a lighted background. A drop of dry yeast suspension was added as food to each vial. Probit analysis was used to determine the concentration at which lethality to brine shrimp represents 50 % (LC50). All the tested extracts showed that the concentration is directly proportional to death of brine shrimps. Fifty percent lethality (LC50) of the tested crude extract ranged between 4.1 and 4.6 µg/ml with methanol extract of B. abyssinica being the lowest and T. acutiloba the highest. This study revealed that 100% of plant crude extracts screened for activity against Artemisia salina larvae showed strong cytotoxicity below 10 µg/ml and plant species with LC50 values < 1000 µg/ml may not make good paediatric remedies due to their inherent toxicity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quarles, C. Derrick; Carado, Anthony J.; Barinaga, Charles J.
2012-01-01
A new, low power ionization source for the elemental analysis of aqueous solutions has recently been described. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) source operates at relatively low currents (<20 mA) and solution flow rates (<50 μL min-1), yielding a relatively simple alternative for atomic mass spectrometry applications. The LS-APGD has been interfaced to what is otherwise an organic, LC-MS mass analyzer, the Thermo Scientific Exactive Orbitrap without any modifications; other than removing the electrospray ionization (ESI) source supplied with that instrument. A glow discharge is initiated between the surface of the test solution exiting a glass capillary andmore » a metallic counter electrode mounted at a 90° angle and separated by a distance of ~5 mm. As with any plasma-based ionization source, there are key discharge operation and ion sampling parameters that affect the intensity and composition of the derived mass spectra; including signal-to-background ratios. We describe here a preliminary parametric evaluation of the roles of discharge current, solution flow rate, argon sheath gas flow rate, and ion sampling distance as they apply on this mass analyzer system. A cursive evaluation of potential matrix effects due to the presence of easily ionized elements (EIEs) indicate that sodium concentrations of up to 500 μg mL-1 generally cause suppressions of less than 50%, dependant upon the analyte species. Based on the results of this series of studies, preliminary limits of detection (LOD) have been established through the generation of calibration functions. Whilst solution-based concentrations LOD levels of 0.02 – 2 μg mL-1 3 are not impressive on the surface, the fact that they are determined via discrete 5 μL injections leads to mass-based detection limits at picogram to singlenanogram levels. The overhead costs associated with source operation (10 W d.c. power, solution flow rates of <50 μL min-1, and gas flow rates <10 mL min-1) are very attractive. While further optimization in the source design is suggested here, it is believed that the LS-APGD ion source may present a practical alternative to inductively-coupled plasma (ICP) sources typically employed in elemental mass spectrometry.« less
[Studies for analyzing prohibited ingredients such as tetracaine hydrochloride in cosmetics].
Tokunaga, Hiroshi; Takeuchi, Orie; Uchino, Tadashi; Ando, Masanori
2004-01-01
Tetracaine hydrochloride (TH) is nominated as the prohibited ingredients in cosmetics in Japanese Pharmaceutical Affairs Act. So the analytical method for TH was investigated by HPLC. After adding 5 ml of TH solution at 10 microg/ml and 2 ml of salicylic acid solution at 75 microg/ml as the internal standard to 0.5 g of the lotion, the mixture was made up to 10 ml with a mixture of water and methanol (1:1) as the testing solution. Milky lotion was procedured as follows: After adding 5 ml of TH solution at 10 microg/ml and 2 ml of internal standard solution to 0.5 g of the milky lotion, the mixture was made up to 10 ml with a mixture of water and methanol (1:1). Two milliliter of this mixture was placed into a centrifuging tube with a cap and 2 ml of hexane was added. After shaking vigorously and centrifuging, the lower layer was used as the testing solution. In the case of the cream, the other procedures were used: 0.5 g of cream was placed into a 10-ml volumetric flask and 1 ml of tetrahydrofuran was added. After dissolving, the mixture of methanol and water (1:1) was added to make up 10.0 ml. Two milliliter of this mixture was placed into a centrifuging tube with a cap and 2.0 ml of hexane was added. After shaking vigorously and centrifuging, the lower layer was used as the testing solution. The testing solution of 20 microl was analyzed by HPLC using the ODS column (CAPCELL PAK C18 column, 4.6 x 250 mm), the mixture of acetonitrile and 50 mmol/l phosphate buffer(pH 2.0)(7:3) and the detection wavelength of 303 nm. The working curves from 0.5 to 6.0 microg/ml showed a linear line between the concentrations of TH and the peak area ratio. There was no interference of peak of TH from the lotion, milky lotion and cream.
Silva, S.R.; Kendall, C.; Wilkison, D.H.; Ziegler, A.C.; Chang, Cecily C.Y.; Avanzino, R.J.
2000-01-01
A new method for concentrating nitrate from fresh waters for ??15N and ??18O analysis has been developed and field-tested for four years. The benefits of the method are: (1) elimination of the need to transport large volumes of water to the laboratory for processing; (2) elimination of the need for hazardous preservatives; and (3) the ability to concentrate nitrate from fresh waters. Nitrate is collected by, passing the water-sample through pre-filled, disposable, anion exchanging resin columns in the field. The columns are subsequently transported to the laboratory where the nitrate is extracted, converted to AgNO3 and analyzed for its isotope composition. Nitrate is eluted from the anion exchange columns with 15 ml of 3 M HCl. The nitrate-bearing acid eluant is neutralized with Ag2O, filtered to remove the AgCl precipitate, then freeze-dried to obtain solid AgNO3, which is then combusted to N2 in sealed quartz tubes for ?? 15N analysis. For ?? 18O analysis, aliquots of the neutralized eluant are processed further to remove non-nitrate oxygen-bearing anions and dissolved organic matter. Barium chloride is added to precipitate sulfate and phosphate; the solution is then filtered, passed through a cation exchange column to remove excess Ba2+, re-neutralized with Ag2O, filtered, agitated with activated carbon to remove dissolved organic matter and freeze-dried. The resulting AgNO3 is combusted with graphite in a closed tube to produce CO2, which is cryogenically purified and analyzed for its oxygen isotope composition. The 1?? analytical precisions for ??15N and ??18O are ?? 0.05%o and ??0.5???, respectively, for solutions of KNO3 standard processed through the entire column procedure. High concentrations of anions in solution can interfere with nitrate adsorption on the anion exchange resins, which may result in isotope fractionation of nitrogen and oxygen (fractionation experiments were conducted for nitrogen only; however, fractionation for oxygen is expected). Chloride, sulfate, and potassium biphthalate, an organic acid proxy for dissolved organic material, added to KNO3 standard solutions caused no significant nitrogen fractionation for chloride concentrations below about 200 mg/l (5.6 meq/l) for 1000 ml samples, sulfate concentrations up to 2000 mg/1 (41.7 meq/l) in 100 ml samples, and Potassium biphthalate for concentrations up to 200 mg/l carbon in 100 ml samples. Samples archived on the columns for up to two years show minimal nitrogen isotope fractionation.
Satínský, Dalibor; Havlíková, Lucie; Solich, Petr
2013-08-01
A new and fast high-performance liquid chromatography (HPLC) column-switching method using fused-core columns in both dimensions for sample preconcentration and determination of propranolol in human urine has been developed. On-line sample pretreatment and propranolol preconcentration were performed on an Ascentis Express RP-C-18 guard column (5 × 4.6 mm), particle size, 2.7 μm, with mobile phase acetonitrile/water (5:95, v/v) at a flow rate of 2.0 mL min(-1) and at a temperature of 50 °C. Valve switch from pretreatment column to analytical column was set at 4.0 min in a back-flush mode. Separation of propranolol from other endogenous urine compounds was achieved on the fused-core column Ascentis Express RP-Amide (100 × 4.6 mm), particle size, 2.7 μm, with mobile phase acetonitrile/water solution of 0.5% triethylamine, pH adjusted to 4.5 by means of glacial acetic acid (25:75, v/v), at a flow rate of 1.0 mL min(-1) and at a temperature of 50 °C. Fluorescence excitation/emission detection wavelengths were set at 229/338 nm. A volume of 1,500 μL of filtered urine sample solution was injected directly into the column-switching HPLC system. The total analysis time including on-line sample pretreatment was less than 8 min. The experimentally determined limit of detection of the method was found to be 0.015 ng mL(-1).
NASA Astrophysics Data System (ADS)
dos Santos, Éder José; Herrmann, Amanda Beatriz; de Caires, Suzete Kulik; Frescura, Vera Lúcia Azzolin; Curtius, Adilson José
2009-06-01
A simple and fast method for the determination of Se in biological samples, including food, by axial view inductively coupled plasma optical emission spectrometry using on-line chemical vapor generation (CVG-ICP OES) is proposed. The concentrations of HCl and NaBH 4, used in the chemical vapor generation were optimized by factorial analysis. Six certified materials (non-fat milk powder, lobster hepatopancreas, human hair, whole egg powder, oyster tissue, and lyophilised pig kidney) were treated with 10 mL of aqua regia in a microwave system under reflux for 15 min followed by additional 15 min in an ultrasonic bath. The solutions were transferred to a 100 mL volumetric flask and the final volume was made up with water. The Se was determined directly in these solutions by CVG-ICP OES, using the analytical line at 196.026 nm. Calibration against aqueous standards in 10% v/v aqua regia in the concentration range of 0.5-10.0 µg L - 1 Se(IV) was used for the analysis. The quantification limit, considering a 0.5 g sample weight in a final volume of 100 mL - 1 was 0.10 µg g - 1. The obtained concentration values were in agreement with the total certified concentrations, according to the t-test for a 95% confidence level.
Jackson, Darryl D.; Hollen, Robert M.
1983-01-01
A new automatable cleaning apparatus which makes use of a method of very thoroughly and quickly cleaning a gauze electrode used in chemical analyses is given. The method generates very little waste solution, and this is very important in analyzing radioactive materials, especially in aqueous solutions. The cleaning apparatus can be used in a larger, fully automated controlled potential coulometric apparatus. About 99.98% of a 5 mg. plutonium sample was removed in less than 3 minutes, using only about 60 ml. of rinse solution and two main rinse steps.
Ellis, P C; Pivarnik, L F; Thiam, M; Ellis, P C; Pivarnik, L F; Thiam, M
2000-01-01
Nine collaborating laboratories tested a combination of 23 seafood samples for volatile bases using an ammonia ion selective electrode. Results were reported as mg NH3/100 g fish, but the method reflected levels of both ammonia and trimethylamine, which permeated the ammonia membrane. The 23 samples were broken down into 8 blind duplicate pairs, 2 Youden matched pairs, and 3 single samples covering fresh to spoiled product ranging from 8 to 82 mg NH3/100 g. Seven species were evaluated: Atlantic cod, squid, Atlantic halibut, gray sole, monkfish, dogfish, and Atlantic mackerel. The ammonia electrode assay was performed on an aqueous homogenate consisting of 95 mL distilled water and 5.0 g sample tissue. Alkaline ion strength adjusting solution (2 mL) was added to the homogenate to liberate ammonia that was sensed by the ion specific electrode and measured on a precalibrated portable meter. Repeatability standard deviations (RSDr) ranged from 4.2 to 17%; reproducibility standard deviations (RSDR) ranged from 8.8 to 21%. A standard ammonium chloride solution was provided to all laboratories to spike 3 different samples at 10 mg NH3/100 g. Recoveries of added ammonia as ammonium chloride for fresh, borderline, and spoiled samples were 88.6, 107, and 128%, respectively.
Birgani, Nasrin Taghipour; Elhami, Shahla
2017-01-01
A simple and sensitive method was proposed for the preconcentration of trace levels of Al(III) prior to its determination by spectrophotometry, based on dispersive liquid-liquid microextraction. The complexation of the Al(III) was performed by chelation with Eriochrome Cyanine R (ECR). In this method, cetyltrimethyl ammonium bromide (CTAB) as a dispersant was dissolved in chloroform as an extractant solvent, and then the solution was rapidly injected by a syringe into the samples containing Al(III), which had already been complexed by ECR at optimized pH. Various parameters were studied and optimized for a 10 mL sample volume. Under the optimum conditions, the LOD (3 times the SD of 10 replicate readings of the reagent blank) and the dynamic range of the calibration obtained were 0.2 ng mL-1 (7 nM) and 1.0-80.0 ng mL-1, respectively. The RSDs for eight replicate determinations of 10 and 60 ng mL-1 of Al(III) were 3.3 and 1.8%, respectively. This strategy was successfully applied to determine the Al concentration in water, wastewater, yogurt, apple, carrot, celery, bread, potato, urine, and Al-Mg syrup samples.
Oshita, Koji; Noguchi, Osamu; Oshima, Mitsuko; Motomizu, Shoji
2007-10-01
A chelating resin, cross-linked chitosan modified with the glycine moiety (glycine-type chitosan resin), was developed for the collection and concentration of bismuth in aquatic samples for ICP-MS measurements. The adsorption behavior of bismuth and 55 elements on glycine-type chitosan resin was systematically examined by passing a sample solution containing 56 elements through a mini-column packed with the resin (wet volume; 1 ml). After eluting the elements adsorbed on the resin with nitric acid, the eluates were measured by ICP-MS. The glycine-type chitosan resin could adsorb several cations by a chelating mechanism and several oxoanions by an anion-exchange mechanism. Especially, the resin could adsorb almost 100% Bi(III) over a wide pH region from pH 2 to 6. Bismuth could be strongly adsorbed at pH 3, and eluted quantitatively with 10 ml of 3 M nitric acid. A column pretreatment method with the glycine-type chitosan resin was used prior to removal of high concentrations of matrices in a seawater sample and the preconcentration of trace bismuth in river water samples for ICP-MS measurements. The column pretreatment method was also applied to the determination of bismuth in real samples by ICP-MS. The LOD of bismuth was 0.1 pg ml(-1) by 10-fold column preconcentration for ICP-MS measurements. The analytical results for bismuth in sea and river water samples by ICP-MS were 22.9 +/- 0.5 pg ml(-1) (RSD, 2.2%) and 2.08 +/- 0.05 pg ml(-1) (RSD, 2.4%), respectively.
Extraction and Determination of Cyproheptadine in Human Urine by DLLME-HPLC Method
Maham, Mehdi; Kiarostami, Vahid; Waqif-Husain, Syed; Abroomand-Azar, Parviz; Tehrani, Mohammad Saber; Khoeini Sharifabadi, Malihe; Afrouzi, Hossein; Shapouri, MahmoudReza; Karami-Osboo, Rouhollah
2013-01-01
Novel dispersive liquid-liquid microextraction (DLLME), coupled with high performance liquid chromatography with photodiode array detection (HPLC-DAD) has been applied for the extraction and determination of cyproheptadine (CPH), an antihistamine, in human urine samples. In this method, 0.6 mL of acetonitrile (disperser solvent) containing 30 μL of carbon tetrachloride (extraction solvent) was rapidly injected by a syringe into 5 mL urine sample. After centrifugation, the sedimented phase containing enriched analyte was dissolved in acetonitrile and an aliquot of this solution injected into the HPLC system for analysis. Development of DLLME procedure includes optimization of some important parameters such as kind and volume of extraction and disperser solvent, pH and salt addition. The proposed method has good linearity in the range of 0.02-4.5 μg mL-1 and low detection limit (13.1 ng mL-1). The repeatability of the method, expressed as relative standard deviation was 4.9% (n = 3). This method has also been applied to the analysis of real urine samples with satisfactory relative recoveries in the range of 91.6-101.0%. PMID:24250605
Bioequivalence study of levothyroxine tablets compared to reference tablets and an oral solution.
Koytchev, Rossen; Lauschner, Reinhard
2004-01-01
The study was designed to evaluate the bioequivalence of three levothyroxine sodium (CAS 51-48-9) formulations, i.e. a test and a reference tablet and an oral solution. A bioequivalence study was carried out in 25 healthy volunteers, who were administered a single dose of 600 microg levothyroxine in the form of the test formulation (levothyroxine sodium tablets 200 microg; Eferox), the originator product, and an oral solution. The trial was performed in one study center according to an open, randomized, three-way cross-over design with wash-out periods of 35 days between administration. Blood samples were taken up to 48 h post dose, the plasma was separated and the concentrations of levothyroxine and triiodothyronine were determined by radioimmunoassay with I125 labeling method. The levothyroxine mean Cmax were 112.0+/-17.3 ng/ml, 113.4+/-18.5 ng/ ml and 111.3+/-15.1 ng/ml, while the mean AUC0-24 were 2263.7+/-332.8 ng x h/ ml, 2307.3+/-351.3 ng x h/ml and 2286.1+/-331.0 ng x h/ml for the test and reference tablets as well as for the oral solution, respectively. No significant differences were found of principal pharmacokinetic parameters between the studied formulations. The 90%-confidence interval for the primary target parameters, intra-individual ratios of AUC0-24 and Cmax of levothyroxine were within the acceptance ranges for bioequivalence trials, i.e. AUC0-24 0.954-1.016 and 0.966-1.011 as well as Cmax 0.948-1.027 and 0.968-1.032 for test tablets versus reference tablets and the oral solution, respectively. Similar results were observed for triiodothyronine. In the light of the present study it can be concluded that the levothyroxine test tablet is bioequivalent to the reference formulation in respect of extent and rate of absorption. The results of the present trial confirm the findings of a previous study, performed under steady-state conditions with Eferox tablets 100 microg in patients without thyroid function.
Morphology dependent amplified spontaneous emission in π-conjugated polymer
NASA Astrophysics Data System (ADS)
Wang, Yuchen; Yang, Xiao; Wang, Ruizhi; Li, Li; Li, Heng
2015-08-01
The amplified spontaneous emission (ASE) spectra of a π-conjugated polymer Poly [2-methoxy-5-(2‧-ethylhexyloxy)-1,4-phenylenevinylene] (MEH-PPV) are studied in as-cast film, annealed film, 1 mg/ml solution and 2.5 mg/ml solution, respectively, using a 10 ns pulsed laser as an excitation source. We found that for annealed film (420 K), the ASE is hardly achieved compared to the as-cast film, which is consistent with the formation of the aggregation; whereas the film's temperature had much less effect on its ASE threshold. In solution, the ASE spectra show both 0-0 peak and 0-1 peak in 1 mg/ml solution, but only 0-1 peak in 2.5 mg/ml one. When the temperature of solution increases slightly from 300 K to 330 K, the ASE threshold increases dramatically in 1 mg/ml solution but slightly in 2.5 mg/ml one. Our results show the important role the morphology played in the ASE spectra in both film and solution. Therefore, controlling the interchain interaction in PCPs may be the key factor for performance of the organic lasers.
Schneider, George J; Kuper, Kevin G; Abravaya, Klara; Mullen, Carolyn R; Schmidt, Marion; Bunse-Grassmann, Astrid; Sprenger-Haussels, Markus
2009-04-01
Automated sample preparation systems must meet the demands of routine diagnostics laboratories with regard to performance characteristics and compatibility with downstream assays. In this study, the performance of QIAGEN EZ1 DSP Virus Kit on the BioRobot EZ1 DSP was evaluated in combination with the Abbott RealTime HIV-1, HCV, and HBV assays, followed by thermalcycling and detection on the Abbott m2000rt platform. The following performance characteristics were evaluated: linear range and precision, sensitivity, cross-contamination, effects of interfering substances and correlation. Linearity was observed within the tested ranges (for HIV-1: 2.0-6.0 log copies/ml, HCV: 1.3-6.9 log IU/ml, HBV: 1.6-7.6 log copies/ml). Excellent precision was obtained (inter-assay standard deviation for HIV-1: 0.06-0.17 log copies/ml (>2.17 log copies/ml), HCV: 0.05-0.11 log IU/ml (>2.09 log IU/ml), HBV: 0.03-0.07 log copies/ml (>2.55 log copies/ml)), with good sensitivity (95% hit rates for HIV-1: 50 copies/ml, HCV: 12.5 IU/ml, HBV: 10 IU/ml). No cross-contamination was observed, as well as no negative impact of elevated levels of various interfering substances. In addition, HCV and HBV viral load measurements after BioRobot EZ1 DSP extraction correlated well with those obtained after Abbott m2000sp extraction. This evaluation demonstrates that the QIAGEN EZ1 DSP Virus Kit provides an attractive solution for fully automated, low throughput sample preparation for use with the Abbott RealTime HIV-1, HCV, and HBV assays.
Schwertschlag, U; Nakata, L M; Gal, J
1984-01-01
Several high-pressure liquid chromatography procedures for the determination of flucytosine in serum or plasma have appeared. Some of these suffer from significant disadvantages, and none was applicable in our routine clinical therapeutic-drug-monitoring laboratory. A new high-pressure liquid chromatography assay for flucytosine was therefore developed. A 100-microliter sample of plasma was treated with an aqueous 5-iodocytosine internal-standard solution, and the mixture was deproteinized with trichloroacetic acid. A portion of the protein-free supernatant was diluted with 0.1 M ammonium phosphate, and an aliquot of the resulting solution was injected into the high-pressure liquid chromatography system. Chromatography was performed on a strong-cation-exchange column with a mobile phase containing aqueous ammonium phosphate, phosphoric acid, methanol, and acetonitrile. Detection was at 254 nm. The assay was shown to be linear in the 10 to 200-micrograms/ml drug-concentration range. Forty other drugs were tested for potential interference with the assay, and none was found. For routine use, a single-point working standard containing 75 micrograms of flucytosine per ml was used, giving intraassay coefficients of variation at 50 and 150 micrograms/ml of 1.8 and 2.3% respectively, whereas the day-to-day coefficient of variation at 50 micrograms/ml was 10.0%. Advantages of the procedure include the small sample size, the use of a convenient and reliable internal standard, speed, and simplicity. The assay is highly suitable for routine clinical drug-analysis laboratories. PMID:6508261
Extraction of magnesium from calcined dolomite ore using hydrochloric acid leaching
NASA Astrophysics Data System (ADS)
Royani, Ahmad; Sulistiyono, Eko; Prasetiyo, Agus Budi; Subagja, Rudi
2018-05-01
Magnesium is widely used in varieties industrial sector. Dolomite is one source of magnesium besides seawater. The extraction of magnesium from dolomite ores can be done by leaching process. In this work, the dolomite leaching to extract magnesium by hydrochloric acid was investigated. The leaching experiments were performed in a spherical glass batch reactor having a capacity of 1000 ml. The effects of the stirring speed, acid concentration, reaction temperature and liquid-solid ratio for each reaction time of 1; 2; and 3 h on the Mg leaching have been evaluated. 5 ml of solution sample were collected from the leached solutions, then it was filtered prior to analysis by ICP OES. The experimental results show that the magnesium extraction increases along with the increase of acid concentration, liquid-solid ratio and temperature. The optimum conditions for magnesium extraction were achieved at temperature 75 °C, extraction time 3 h, the HCl concentration of 2 M, the liquid-solid ratio 20 ml/g and stirring speed of 400 rpm. At this condition 98, 82 % of magnesium were extracted from dolomite. The conclusion obtained from this leaching process is that the magnesium can be extracted from dolomite by using hydrochloric acid solutions.
Aumeran, C.; Thibert, E.; Chapelle, F. A.; Hennequin, C.; Lesens, O.
2012-01-01
Opinions differ on the value of microbiological testing of endoscopes, which varies according to the technique used. We compared the efficacy on bacterial biofilms of sampling solutions used for the surveillance of the contamination of endoscope channels. To compare efficacy, we used an experimental model of a 48-h Pseudomonas biofilm grown on endoscope internal tubing. Sampling of this experimental biofilm was performed with a Tween 80-lecithin-based solution, saline, and sterile water. We also performed a randomized prospective study during routine clinical practice in our hospital sampling randomly with two different solutions the endoscopes after reprocessing. Biofilm recovery expressed as a logarithmic ratio of bacteria recovered on bacteria initially present in biofilm was significantly more effective with the Tween 80-lecithin-based solution than with saline solution (P = 0.002) and sterile water (P = 0.002). There was no significant difference between saline and sterile water. In the randomized clinical study, the rates of endoscopes that were contaminated with the Tween 80-lecithin-based sampling solution and the saline were 8/25 and 1/25, respectively (P = 0.02), and the mean numbers of bacteria recovered were 281 and 19 CFU/100 ml (P = 0.001), respectively. In conclusion, the efficiency and therefore the value of the monitoring of endoscope reprocessing by microbiological cultures is dependent on the sampling solutions used. A sampling solution with a tensioactive action is more efficient than saline in detecting biofilm contamination of endoscopes. PMID:22170930
1983-08-01
nitrotetrazole) (Cuen2 (NT)2 ) [7) A solution of sodium nitrite (26 g) and cupric sulfate pentahydrate (13.75 g) in water (75 ml) was placed in the 600 ml...pan and cooled to 50C. To this stirred solution was added a solution of 5-aminotetrazole monohydrate (12.9 g), cupric sulfate pentahydrate (1.0 g) and...stirring then a solution of cupric sulfate pentahydrate (5.25 q) and ethylenediamine (11.25 ml) in water (20 ml) was added. Stirring and heating were
NASA Astrophysics Data System (ADS)
Sugimoto, Futoshi
Foam separation of high concentration chromium in leather tanning wastewater was investigated using casein protein as a foaming reagent5mL of5w/v% ammonium acetate buffer was added to the sample chromium water. After adjusting the pH to 9.0,4g/L concentrations of casein and gelatin solution were added to recovery the coagulating flocs of chromium resulting foam separation. The sample water containing chromium flocs was incased in reactor, then mixed with distilled water and 1mL of ethanol to sum 200mL total. The foam separation was performed at time intervals of 3min with an air flow rate of 300mL/min. With casein reagent, the removal rate of chromium was not influenced by the presence of NaCl, however, the rate decreased tendency using with the use of gelatin. The proposed method, utilizing 4g/L of casein solution with water, was not influenced by the presence of calcium (<34mM), magnesium (<1mM), carbonate (<0.5mM), bicarbonate (<1.2mM) nor sulfate (<350mM) ions, and is ideal for foam separation in chromium concentrations of about 100mgCr/L.
1988-01-01
Lindsey 13 yielded 9, 1O-dimethyl-2,3,6,7-tetramethoxyanthracene (13) by condensing veratrole (12) and acetaldehyde in the presence of sulfuric acid...combination of those cited by Boldt12 and Lindsey.13 To an ice cooled solution of veratrole (32 mL, 250 mmol) in acetic acid (125 mL) was slowly added...solution of veratrole (32 mL, 250 mmol) in acetic acid (125 mL) was slowly added an ice cooled solution of benzaldehyde ( 25 mL, 246 mmol) in methanol
NASA Astrophysics Data System (ADS)
Farahmand, Farnaz; Ghasemzadeh, Bahar; Naseri, Abdolhossein
2018-01-01
An air assisted liquid-liquid microextraction by applying the solidification of a floating organic droplet method (AALLME-SFOD) coupled with a multivariate calibration method, namely partial least squares (PLS), was introduced for the fast and easy determination of Atenolol (ATE), Propanolol (PRO) and Carvedilol (CAR) in biological samples via a spectrophotometric approach. The analytes would be extracted from neutral aqueous solution into 1-dodecanol as an organic solvent, using AALLME. In this approach a low-density solvent with a melting point close to room temperature was applied as the extraction solvent. The emulsion was immediately formed by repeatedly pulling in and pushing out the aqueous sample solution and extraction solvent mixture via a 10-mL glass syringe for ten times. After centrifugation, the extractant droplet could be simply collected from the aqueous samples by solidifying the emulsion at a lower than the melting point temperature. In the next step, analytes were back extracted simultaneously into the acidic aqueous solution. Derringer and Suich multi-response optimization were utilized for simultaneous optimizing the parameters of three analytes. This method incorporates the benefits of AALLME and dispersive liquid-liquid microextraction considering the solidification of floating organic droplets (DLLME-SFOD). Calibration graphs under optimized conditions were linear in the range of 0.30-6.00, 0.32-2.00 and 0.30-1.40 μg mL- 1 for ATE, CAR and PRO, respectively. Other analytical parameters were obtained as follows: enrichment factors (EFs) were found to be 11.24, 16.55 and 14.90, and limits of detection (LODs) were determined to be 0.09, 0.10 and 0.08 μg mL- 1 for ATE, CAR and PRO, respectively. The proposed method will require neither a highly toxic chlorinated solvent for extraction nor an organic dispersive solvent in the application process; hence, it is more environmentally friendly.
Farahmand, Farnaz; Ghasemzadeh, Bahar; Naseri, Abdolhossein
2018-01-05
An air assisted liquid-liquid microextraction by applying the solidification of a floating organic droplet method (AALLME-SFOD) coupled with a multivariate calibration method, namely partial least squares (PLS), was introduced for the fast and easy determination of Atenolol (ATE), Propanolol (PRO) and Carvedilol (CAR) in biological samples via a spectrophotometric approach. The analytes would be extracted from neutral aqueous solution into 1-dodecanol as an organic solvent, using AALLME. In this approach a low-density solvent with a melting point close to room temperature was applied as the extraction solvent. The emulsion was immediately formed by repeatedly pulling in and pushing out the aqueous sample solution and extraction solvent mixture via a 10-mL glass syringe for ten times. After centrifugation, the extractant droplet could be simply collected from the aqueous samples by solidifying the emulsion at a lower than the melting point temperature. In the next step, analytes were back extracted simultaneously into the acidic aqueous solution. Derringer and Suich multi-response optimization were utilized for simultaneous optimizing the parameters of three analytes. This method incorporates the benefits of AALLME and dispersive liquid-liquid microextraction considering the solidification of floating organic droplets (DLLME-SFOD). Calibration graphs under optimized conditions were linear in the range of 0.30-6.00, 0.32-2.00 and 0.30-1.40μg mL -1 for ATE, CAR and PRO, respectively. Other analytical parameters were obtained as follows: enrichment factors (EFs) were found to be 11.24, 16.55 and 14.90, and limits of detection (LODs) were determined to be 0.09, 0.10 and 0.08μg mL -1 for ATE, CAR and PRO, respectively. The proposed method will require neither a highly toxic chlorinated solvent for extraction nor an organic dispersive solvent in the application process; hence, it is more environmentally friendly. Copyright © 2017 Elsevier B.V. All rights reserved.
Peng, Guilong; He, Qiang; Al-Hamadani, Sulala M Z F; Zhou, Guangming; Liu, Mengzi; Zhu, Hui; Chen, Junhua
2015-05-01
Dispersive liquid-liquid microextraction with solidification of a floating organic droplet (DLLME-SFO) followed by high performance liquid chromatography-ultraviolet (HPLC-UV) detection was applied for the determination of thiamphenicol (TAP), florfenicol (FF) in water samples. 1-Undecanol was used as the extraction solvent which has lower density than water, low toxicity, and low melting point (19°C). A mixture of 800mL acetone (disperser solvent) and 80µL of 1-undecanol (extraction solvent) was injected into 20mL of aqueous solution. After 5min, 0.6g of NaCl was added and the sample vial was shaken. After 5min, the sample was centrifuged at 3500rpm for 3min, and then placed in an ice bath. When the extraction solvent floating on the aqueous solution had solidified, it was transferred into another conical vial where it was melted quickly at room temperature, and was diluted with methanol to 1mL, and analyzed by HPLC-UV detection. Parameters influencing the extraction efficiency were thoroughly examined and optimized. The extraction recoveries (ER) and the enrichment factors (EF) ranged from 67% to 72% and 223 to 241, respectively. The limits of detection (LODs) (S/N=3) were 0.33 and 0.56µgL(-1) for TAP and FF, respectively. Linear dynamic range (LDR) was in the range of 1.0-550µgL(-1) for TAP and 1.5-700µgL(-1) for FF, the relative standard deviations (RSDs) were in the range of 2.6-3.5% and the recoveries of spiked samples ranged from 94% to 106%. Copyright © 2015 Elsevier Inc. All rights reserved.
Ghazaghi, Mehri; Mousavi, Hassan Zavvar; Rashidi, Ali Morad; Shirkhanloo, Hamid; Rahighi, Reza
2016-01-01
A uniquely novel, fast, and facile technique is introduced for the first time in which a scant amount of graphene oxide (GO), without modification, has been utilized in dispersive mode of solid phase extraction (SPE) for an efficient yet simple separation. The proposed method of coagulating homogenous dispersive micro solid phase extraction (CHD-µSPE) is based on coagulation of homogeneous GO solution with the aid of polyetheneimine (PEI). CHD-µSPE use full adsorption capacity of GO because in this method was used GO solution obtained from synthesis process without drying step and stacking nanosheets. In optimized condition, 30 µL GO solution (7 mg mL(-1)), obtained in synthesis process, was injected into 1.5 mL the sample solution followed by immediate injection of 53 µL PEI solution (1 mg mL(-1)). After inserting PEI, GO sheets aggregate and can be readily separated by centrifugation. PEI not only cause aggregation of GO, but also form three-dimensional network of GO with easy handling in following separation steps. Lead, cadmium, and chromium were selected as model analytes and the effecting parameters including the amount of GO, concentration of PEI, sample pH, extraction time, and type of desorption solvent were investigated and optimized. The results indicate that the proposed CHD-µSPE method can be successfully applied GO in dispersive mode of SPE without effecting on good capability adsorption of GO. The novel method was applied in determination of lead, cadmium, and chromium in water, human saliva, and urine samples by electrothermal atomic absorption spectrometry. The detection limits are as low as 0.035, 0.005, and 0.012 µg L(-1) for Pb, Cd, and Cr respectively. The intra-day precisions (RSDs) were lower than 3.8%. CHD-µSPE method showed a good linear ranges of 0.24-15.6, 0.015-0.95 and 0.039-2.33 µg L(-1) for Pb, Cd and Cr respectively. Method performance was investigated by determination of mentioned metal ions in river water, human urine and saliva sample with good recoveries in range of 94.2-103.0%. The accuracy of the method was underpinned by correct analysis of a standard reference material (SRM: 2668 level I, Urine). Copyright © 2015 Elsevier B.V. All rights reserved.
Afzali, Darush; Mostafavi, Ali; Taher, Mohammad Ali; Rezaeipour, Ebrahim; Khayatzadeh Mahani, Mohammad
2005-04-01
A procedure for separation and preconcentration of trace amounts of cadmium has been proposed. A column of analcime zeolite modified with benzyldimethyltetradecylammonium chloride and loaded with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) was used for retention of cadmium. The cadmium was quantitatively retained on the column at pH approximately 9 and was recovered from column with 5 ml of 2 M nitric acid with a preconcentration factor of 140. Anodic stripping differential pulse voltammetry was used for determination of cadmium. A 0.05 ng/ml detection limit for the preconcentration of aqueous solution of cadmium was obtained. The relative standard deviation (RSD) for eight replicate determinations at the 1 microg/ml cadmium levels was 0.31% (calculated with the peak height obtained). The calibration graph using the preconcentration system was linear from 0.01 to 150 microg/ml in final solution with a correlation coefficient of 0.9997. For optimization of conditions, various parameters such as the effect of pH, flow rate, instrumental conditions and interference of number of ions, were studied in detail. This method was successfully applied for determination of cadmium in various complex samples.
Jackson, D.D.; Hollen, R.M.
1981-02-27
A method of very thoroughly and quikcly cleaning a guaze electrode used in chemical analyses is given, as well as an automobile cleaning apparatus which makes use of the method. The method generates very little waste solution, and this is very important in analyzing radioactive materials, especially in aqueous solutions. The cleaning apparatus can be used in a larger, fully automated controlled potential coulometric apparatus. About 99.98% of a 5 mg plutonium sample was removed in less than 3 minutes, using only about 60 ml of rinse solution and two main rinse steps.
Li, FuKai; Gong, AiJun; Qiu, LiNa; Zhang, WeiWei; Li, JingRui; Liu, Yu; Liu, YuNing; Yuan, HuiTing
2017-01-01
The determination of trace rare-earth elements (REEs) can be used for the assessment of environmental pollution, and is of great significance to the study of toxicity and toxicology in animals and plants. N, N, N', N'-tetraoctyl diglycolamide (TODGA) is an environmental friendly extractant that is highly selective to REEs. In this study, an analytical method was developed for the simultaneous determination of 16 trace REEs in simulated water samples by inductively coupled plasma optical emission spectroscopy (ICP-OES). With this method, TODGA was used as the extractant to perform the liquid-liquid extraction (LLE) sample pretreatment procedure. All 16 REEs were extracted from a 3 M nitric acid medium into an organic phase by a 0.025 M TODGA petroleum ether solution. A 0.03 M ethylenediaminetetraacetic acid disodium salt (EDTA) solution was used for back-extraction to strip the REEs from the organic phase into the aqueous phase. The aqueous phase was concentrated using a vacuum rotary evaporator and the concentration of the 16 REEs was detected by ICP-OES. Under the optimum experimental conditions, the limits of detection (3σ, n = 7) for the REEs ranged from 0.0405 ng mL-1 (Nd) to 0.5038 ng mL-1 (Ho). The relative standard deviations (c = 100 ng mL-1, n = 7) were from 0.5% (Eu) to 4.0% (Tm) with a linear range of 4-1000 ng mL-1 (R2 > 0.999). The recoveries of 16 REEs ranged from 95% to 106%. The LLE-ICP-OES method established in this study has the advantages of simple operation, low detection limits, fast analysis speed and the ability to simultaneously determine 16 REEs, thereby acting as a viable alternative for the simultaneous detection of trace amounts of REEs in water samples.
Li, FuKai; Qiu, LiNa; Zhang, WeiWei; Li, JingRui; Liu, Yu; Liu, YuNing; Yuan, HuiTing
2017-01-01
The determination of trace rare-earth elements (REEs) can be used for the assessment of environmental pollution, and is of great significance to the study of toxicity and toxicology in animals and plants. N, N, N′, N′-tetraoctyl diglycolamide (TODGA) is an environmental friendly extractant that is highly selective to REEs. In this study, an analytical method was developed for the simultaneous determination of 16 trace REEs in simulated water samples by inductively coupled plasma optical emission spectroscopy (ICP-OES). With this method, TODGA was used as the extractant to perform the liquid-liquid extraction (LLE) sample pretreatment procedure. All 16 REEs were extracted from a 3 M nitric acid medium into an organic phase by a 0.025 M TODGA petroleum ether solution. A 0.03 M ethylenediaminetetraacetic acid disodium salt (EDTA) solution was used for back-extraction to strip the REEs from the organic phase into the aqueous phase. The aqueous phase was concentrated using a vacuum rotary evaporator and the concentration of the 16 REEs was detected by ICP-OES. Under the optimum experimental conditions, the limits of detection (3σ, n = 7) for the REEs ranged from 0.0405 ng mL-1 (Nd) to 0.5038 ng mL-1 (Ho). The relative standard deviations (c = 100 ng mL-1, n = 7) were from 0.5% (Eu) to 4.0% (Tm) with a linear range of 4–1000 ng mL-1 (R2 > 0.999). The recoveries of 16 REEs ranged from 95% to 106%. The LLE-ICP-OES method established in this study has the advantages of simple operation, low detection limits, fast analysis speed and the ability to simultaneously determine 16 REEs, thereby acting as a viable alternative for the simultaneous detection of trace amounts of REEs in water samples. PMID:28945788
High sensitivity detection of bisphenol A using liposome chromatography.
Liu, Xue-Ying; Nakamura, Chikashi; Tanimoto, Itsuro; Miyake, Shiro; Nakamura, Noriyuki; Hirano, Takashi; Miyake, Jun
2006-09-18
An antibody column in tandem with a fluorescent dye entrapped liposome column was developed for highly sensitive detection of an endocrine disruptor, bisphenol A (BPA). Anti-BPA antibody was immobilized in a protein G column with orientation control. A derivative of BPA was conjugated to phospholipase A2 (PLA2). BPA sample solutions mixed with the BPA-PLA2 conjugates were injected on to the anti-BPA antibody column and competitive binding occurred in the antibody column. The amount of the free conjugate was proportional to the concentration of the BPA sample. The eluted conjugates were injected on to the second column gel on which calcein-entrapped liposomes were immobilized and the PLA2-catalyzed hydrolysis of liposomal phospholipids causing fluorescent dye leakage as a signal amplification. In this system, the mixture of BPA and BPA-PLA2 conjugate were incubated for 60 min in the anti-BPA column, and then the collected solution was applied to the liposome column. The BPA detection range of 0.02-140 ng mL(-1) was wider than 0.03-6.6 ng mL(-1) obtained by the method of competitive ELISA using the same antibody. Moreover, this system could be adapted to an HPLC system resulting in almost the same detection limit in online detection. The method could be applied to environmental samples, river water and soil extracts. The BPA concentration of 0.1 ng mL(-1) and 10 ng g(-1) was detectable in water and soil extract, respectively.
Vicentino, Priscila O; Cassella, Ricardo J
2017-01-01
This paper proposes a novel approach for the extraction of Hg from Brazilian gasoline samples: extraction induced by microemulsion breaking (EIMB). In this approach, a microemulsion is formed by mixing the sample with n-propanol and HCl. Afterwards, the microemulsion is destabilized by the addition of water and the two phases are separated: (i) the top phase, containing the residual gasoline and (ii) the bottom phase, containing the extracted analyte in a medium containing water, n-propanol and the ethanol originally present in the gasoline sample. The bottom phase is then collected and the Hg is measured by cold vapor atomic absorption spectrometry (CV-AAS). This model study used Brazilian gasoline samples spiked with Hg (organometallic compound) to optimize the process. Under the optimum extraction conditions, the microemulsion was prepared by mixing 8.7mL of sample with 1.2mL of n-propanol and 0.1mL of a 10molL -1 HCl solution. Emulsion breaking was induced by adding 300µL of deionized water and the bottom phase was collected for the measurement of Hg. Six samples of Brazilian gasoline were spiked with Hg in the organometallic form and recovery percentages in the range of 88-109% were observed. Copyright © 2016 Elsevier B.V. All rights reserved.
2015-01-01
conductive tubing direc ted the aerosol into a heat sealed plastic bag (Food Saver; Jarden Consumer Solutions, Rye, NY), measuring 589 cm 9 254...a self sealing injection port attached to each bag with an adhesive. Approximately 100 mg of iodine crystals were stored at 35°C in an Erlenmeyer...was collected in a bag, 075 ml was drawn from the headspace into a 1 ml syringe and needle and immediately injected through the port into the sample
Mitchell, J B; Braun, W A; Pizza, F X; Forrest, M
2000-03-01
The purpose of this study was to determine the influence of ingesting solutions containing mixtures of carbohydrate (CHO) types on pre-exercise glycemic response, exercise-induced hypoglycemia, metabolic responses, and 10-km treadmill running performance in a warm environment. Ten trained runners completed 6, self-paced 10-km treadmill runs one hour after ingesting 900 ml of one of the following test solutions: a water placebo (WP), an 8 g 100 ml-1 high fructose corn syrup solution (HFG; 72 g CHO), a 6 g 100 ml-1 glucose solution (GLU; 54 g CHO), a 6 g.100 ml-1 sucrose/glucose mixture (SUG; 54 g CHO), or banana with water to equal 900 ml (BAN; approx. 54 g CHO). The sixth condition was 675 ml of an 8 g.100 ml-1 HFCS solution (LFG; 54 g CHO). Blood samples were taken prior to ingestion and every 15 min during rest and at 15 and 30 min, and at the end of the 10-km run. Blood was analyzed for glucose (BG) insulin (IN), glycerol, lactate, and percent change in plasma volume. Urine volume during the 1 hour of rest and change in body mass during exercise were also determined. A significant (p < 0.05) correlation (r = -0.684) was seen between the pre-exercise glycemic response (PEGR = area under the resting BG curve) and the change in BG from pre-EX to 15 min of exercise. BG at 15 min of exercise was significantly higher in the WP (5.22 mM) versus the other conditions (HFG = 3.32, LFG = 3.91, GLU = 3.38, BAN = 3.74 & SUG = 3.63 mM). Pre-exercise IN was lower in the WP (6.54 U ml-1) condition versus the other conditions (HFG = 22.1, LFG = 16.2, GLU = 23.3, BAN = 18.8 & SUG = 12.8 U.ml-1). Ten km performance times were not different (WP = 41.87, HFG = 41.66, LFG = 41.79, GLU = 41.65, BAN = 41.53, and SUG = 41.75 min). A significantly greater body mass loss occurred due to urine production during the 60 min of rest in the WP compared to the other conditions. The degree of exercise-induced decline in blood glucose was related to the PEGR; however, the decline in BG did not affect 10-km running performance. In addition, there were no differences in the metabolic responses during exercise between the different CHO types, nor did the type of CHO influence running performance. Finally, the presence of CHO and/or electrolytes in the hydration solutions produced a better fluid retention during the 60-min pre-exercise rest period compared to water. The results confirmed that if a competitive athlete consumed a breakfast prior to ingesting a CHO-electrolyte beverage, a practice that is common, the glycemic responses may be different.
Stability of acetylcysteine solution repackaged in oral syringes and associated cost savings.
Kiser, Tyree H; Oldland, Alan R; Fish, Douglas N
2007-04-01
The physical and chemical stability of repackaged acetylcysteine 600 mg/3 mL solution in oral syringes stored under refrigeration or at room temperature was studied for six months; a cost analysis was also conducted. Acetylcysteine 20% solution for inhalation was repackaged undiluted as 600 mg/3 mL in capped oral syringes and stored either under refrigeration or at room temperature exposed to fluorescent light. Four samples for each storage condition were analyzed in duplicate on day zero, weekly for the first month, and then every two weeks during months 2-6. Physical stability was assessed, and the chemical stability of acetylcysteine was evaluated by high-performance liquid chromatography. Acetylcysteine solution in syringes was physically stable during the entire six-month study period. When stored at room temperature, acetylcysteine retained 99% of the original concentration at three months and 95% at six months after preparation of the syringes. Loss of acetylcysteine was <2% at six months when stored under refrigeration. Packaging acetylcysteine in batches of 100 syringes instead of preparing individual syringes reduced wastage to zero syringes, saving an estimated $247 in drug costs. The estimated pharmacy time savings was 30 hours ($702). Acetylcysteine 20% solution repackaged as 600 mg/3 mL in oral syringes is both physically and chemically stable under refrigeration or at room temperature under normal fluorescent lighting for six months. The total loss of acetylcysteine was approximately 5% at room temperature under fluorescent lighting and <2% under refrigeration. Repackaging the solution in syringes in bulk rather than in single doses demonstrated a measurable cost saving.
High sensitivity pyrogen testing in water and dialysis solutions.
Daneshian, Mardas; Wendel, Albrecht; Hartung, Thomas; von Aulock, Sonja
2008-07-20
The dialysis patient is confronted with hundreds of litres of dialysis solution per week, which pass the natural protective barriers of the body and are brought into contact with the tissue directly in the case of peritoneal dialysis or indirectly in the case of renal dialysis (hemodialysis). The components can be tested for living specimens or dead pyrogenic (fever-inducing) contaminations. The former is usually detected by cultivation and the latter by the endotoxin-specific Limulus Amoebocyte Lysate Assay (LAL). However, the LAL assay does not reflect the response of the human immune system to the wide variety of possible pyrogenic contaminations in dialysis fluids. Furthermore, the test is limited in its sensitivity to detect extremely low concentrations of pyrogens, which in their sum result in chronic pathologies in dialysis patients. The In vitro Pyrogen Test (IPT) employs human whole blood to detect the spectrum of pyrogens to which humans respond by measuring the release of the endogenous fever mediator interleukin-1beta. Spike recovery checks exclude interference. The test has been validated in an international study for pyrogen detection in injectable solutions. In this study we adapted the IPT to the testing of dialysis solutions. Preincubation of 50 ml spiked samples with albumin-coated microspheres enhanced the sensitivity of the assay to detect contaminations down to 0.1 pg/ml LPS or 0.001 EU/ml in water or saline and allowed pyrogen detection in dialysis concentrates or final working solutions. This method offers high sensitivity detection of human-relevant pyrogens in dialysis solutions and components.
Mammana, Sabrina B; Berton, Paula; Camargo, Alejandra B; Lascalea, Gustavo E; Altamirano, Jorgelina C
2017-05-01
An analytical methodology based on coprecipitation-assisted coacervative extraction coupled to HPLC-UV was developed for determination of five organophosphorus pesticides (OPPs), including fenitrothion, guthion, parathion, methidathion, and chlorpyrifos, in water samples. It involves a green technique leading to an efficient and simple analytical methodology suitable for high-throughput analysis. Relevant physicochemical variables were studied and optimized on the analytical response of each OPP. Under optimized conditions, the resulting methodology was as follows: an aliquot of 9 mL of water sample was placed into a centrifuge tube and 0.5 mL sodium citrate 0.1 M, pH 4; 0.08 mL Al 2 (SO 4 ) 3 0.1 M; and 0.7 mL SDS 0.1 M were added and homogenized. After centrifugation the supernatant was discarded. A 700 μL aliquot of the coacervate-rich phase obtained was dissolved with 300 μL of methanol and 20 μL of the resulting solution was analyzed by HPLC-UV. The resulting LODs ranged within 0.7-2.5 ng/mL and the achieved RSD and recovery values were <8% (n = 3) and >81%, respectively. The proposed analytical methodology was successfully applied for the analysis of five OPPs in water samples for human consumption of different locations of Mendoza. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
[Studies for analyzing the prohibited ingredients such as acetohexamide in cosmetics].
Tokunaga, Hiroshi; Uchino, Tadashi
2005-01-01
Acetohexamide (AH) is nominated as the prohibited ingredients in cosmetics in Japanese Pharmaceutical Affairs Act. So the analytical method for AH was investigated by HPLC. The lotion or milky lotion of 0.5g was put into a 10-ml volumetric flask. After adding 1.0ml of AH solution at 50 microg/ml into the volumetric flask, the mixture was made up to 10ml with methanol as the testing solution. Creams were procedured as follows; 0.5 g of cream was put into a 10-ml volumetric flask. After adding 1.0ml of tetrahydrofuran into the volumetric flask, the mixture was stirred for several minutes and the ingredients of the creams were dissolved. After adding 1.0ml of AH solution at 50 microg/ml into the volumetric flask, the mixture was made up to 10ml with methanol. One milliliter of the mixture including AH at 5 microg/ml was exactly put into a test tube with a cap and then 1 ml of water and 1 ml of hexane were added. After shaking vigorously, stand for several minutes. After centrifuging, the hexane layer was eliminated and the residual mixture was used as the test solution. The testing solution of 20 microl was analyzed by HPLC using the ODS column (CAPCELL PAK C18 column, 4.6 x 250mm), the mixture of acetonitrile and 50 mmol/l phosphate buffer(pH 5.3)(3:1) and the detection wavelength of 247 nm. The working curve from 0.5 to 6.0 microg/ml showed a linear line between the concentrations of AH and the peak areas. There was no interference of peak of AH with the ingredients such as methylparaben, ethylparaben in the lotions, milky lotion and creams.
[Studies for analyzing prohibited ingredients such as estriol in cosmetics].
Tokunaga, Hiroshi; Takeuchi, Orie; Uchino, Tadashi; Ando, Masanori
2004-01-01
Estriol (EO) is nominated as the prohibited ingredients in cosmetics in Japanese Pharmaceutical Affairs Act. So the analytical method using HPLC for EO was investigated. After placing 1.0 ml of EO solution at 50 microg/ml and 0.5 g of the lotion into a 10-ml volumetric flask, the methanol was added to make until that volume and this solution was used as the testing solution. Milky lotion was procedured as follows: After placing 1.0 ml of EO solution at 50 microg/ml and 0.5 g of the milky lotion into a 10-ml volumetric flask, the methanol was added to make until that volume. The suspending mixture was moved to a centrifuging tube with a cap. After centrifuging at 3000 rpm for 5 minutes, the supernatant was used as the testing solution. The testing solution of 20 microl was determined by HPLC using the ODS column (CAPCELL PAK C18 column, 4.6 x 250 mm), the mixture of water and acetonitrile (31:9) and the detection wavelength of 285 nm. The working curve from 1.0 to 6.0 microg/ml showed a linear line between the concentrations of EO and the peak area. There was no interference of peak of EO from the lotion and milky lotion.
Míguez-Framil, Martha; Moreda-Piñeiro, Antonio; Bermejo-Barrera, Pilar; Alvarez-Freire, Iván; Tabernero, María Jesús; Bermejo, Ana María
2010-10-08
A simple and fast sample pre-treatment method based on matrix solid-phase dispersion (MSPD) for isolating cocaine, benzoylecgonine (BZE), codeine, morphine and 6-monoacethylmorphine (6-MAM) from human hair has been developed. The MSPD approach consisted of using alumina (1.80 g) as a dispersing agent and 0.6M hydrochloric acid (4 mL) as an extracting solvent. For a fixed hair sample mass of 0.050 g, the alumina mass to sample mass ratio obtained was 36. A previously conditioned Oasis HLB cartridge (2 mL methanol, plus 2 mL ultrapure water, plus 1 mL of 0.2M/0.2M sodium hydroxide/boric acid buffer solution at pH 9.2) was attached to the end of the MSPD syringe for on column clean-up of the hydrochloric acid extract and for transferring the target compounds to a suitable solvent for gas chromatography (GC) analysis. Therefore, the adsorbed analytes were directly eluted from the Oasis HLB cartridges with 2 mL of 2% acetic acid in methanol before concentration by N(2) stream evaporation and dry extract derivatization with N-methyl-tert-butylsilyltrifluoroacetamide (BSTFA) and chlorotrimethylsilane (TMCS). The optimization/evaluation of all the factors affecting the MSPD and on column clean-up procedures has led to a fast sample treatment, and analytes extraction and pre-concentration can be finished in approximately 30 min. The developed method has been applied to eight hair samples from poli-drug abusers and measured analyte concentrations have been found to be statistically similar (95% confidence interval) to those obtained after a conventional enzymatic hydrolysis method (Pronase E). Copyright © 2010. Published by Elsevier B.V.
James, Lewis J; Evans, Gethin H; Madin, Joshua; Scott, Darren; Stepney, Michael; Harris, Russell; Stone, Robert; Clayton, David J
2013-10-01
The present study investigated the relationship between the milk protein content of a rehydration solution and fluid balance after exercise-induced dehydration. On three occasions, eight healthy males were dehydrated to an identical degree of body mass loss (BML, approximately 1·8%) by intermittent cycling in the heat, rehydrating with 150% of their BML over 1 h with either a 60 g/l carbohydrate solution (C), a 40 g/l carbohydrate, 20 g/l milk protein solution (CP20) or a 20 g/l carbohydrate, 40 g/l milk protein solution (CP40). Urine samples were collected pre-exercise, post-exercise, post-rehydration and for a further 4 h. Subjects produced less urine after ingesting the CP20 or CP40 drink compared with the C drink (P<0·01), and at the end of the study, more of the CP20 (59 (SD 12)%) and CP40 (64 (SD 6)%) drinks had been retained compared with the C drink (46 (SD 9)%) (P<0·01). At the end of the study, whole-body net fluid balance was more negative for trial C (- 470 (SD 154) ml) compared with both trials CP20 (- 181 (SD 280) ml) and CP40 (2107 (SD 126) ml) (P<0·01). At 2 and 3 h after drink ingestion, urine osmolality was greater for trials CP20 and CP40 compared with trial C (P<0·05). The present study further demonstrates that after exercise-induced dehydration, a carbohydrate--milk protein solution is better retained than a carbohydrate solution. The results also suggest that high concentrations of milk protein are not more beneficial in terms of fluid retention than low concentrations of milk protein following exercise-induced dehydration.
NASA Astrophysics Data System (ADS)
Tyburska, Anna; Jankowski, Krzysztof; Rodzik, Agnieszka
2011-07-01
A hydride generation headspace solid phase microextraction technique has been developed in combination with optical emission spectrometry for determination of total arsenic and selenium. Hydrides were generated in a 10 mL volume septum-sealed vial and subsequently collected onto a polydimethylsiloxane/Carboxen solid phase microextraction fiber from the headspace of sample solution. After completion of the sorption, the fiber was transferred into a thermal desorption unit and the analytes were vaporized and directly introduced into argon inductively coupled plasma or helium microwave induced plasma radiation source. Experimental conditions of hydride formation reaction as well as sorption and desorption of analytes have been optimized showing the significant effect of the type of the solid phase microextraction fiber coating, the sorption time and hydrochloric acid concentration of the sample solution on analytical characteristics of the method developed. The limits of detection of arsenic and selenium were 0.1 and 0.8 ng mL - 1 , respectively. The limit of detection of selenium could be improved further using biosorption with baker's yeast Saccharomyces cerevisiae for analyte preconcentration. The technique was applied for the determination of total As and Se in real samples.
Determination of dissolved aluminum in water samples
Afifi, A.A.
1983-01-01
A technique has been modified for determination of a wide range of concentrations of dissolved aluminum (Al) in water and has been tested. In this technique, aluminum is complexed with 8-hydroxyquinoline at pH 8.3 to minimize interferences, then extracted with methyl isobutyl ketone (MIBK). The extract is analyzed colorimetrically at 395 nm. This technique is used to analyze two forms of monomeric Al, nonlabile (organic complexes) and labile (free, Al, Al sulfate, fluoride and hydroxide complexes). A detection limit 2 ug/L is possible with 25-ml samples and 10-ml extracts. The detection limit can be decreased by increasing the volume of the sample and (or) decreasing the volume of the methyl isobutyl ketone extract. The analytical uncertainty of this method is approximately + or - 5 percent. The standard addition technique provides a recovery test for this technique and ensures precision in samples of low Al concentrations. The average percentage recovery of the added Al plus the amount originally present was 99 percent. Data obtained from analyses of filtered standard solutions indicated that Al is adsorbed on various types of filters. However, the relationship between Al concentrations and adsorption remains linear. A test on standard solutions also indicated that Al is not adsorbed on nitric acid-washed polyethylene and polypropylene bottle wells. (USGS)
Zhao, Enfa; Cheng, Gesheng; Wang, Yingli
2017-01-01
The aim of this study is to evaluate the ability of two different contrast agents to detect cardiac right-to-left shunting in patients with a patent foramen ovale during contrast transthoracic echocardiography and transesophageal echocardiography. Eighty-four patients who had migraines or experienced cryptogenic stroke were prospectively enrolled. Contrast echocardiography of the right portion of the heart was performed using an injection of either (i) 8 ml of agitated saline, 1 ml of blood, and 1 ml of air (ASB) or (ii) 4 ml of vitamin B6 and 6 ml of sodium bicarbonate solution (VSBS). All patients underwent contrast echocardiography with different contrast agents successively before undergoing transesophageal echocardiography. The diagnostic sensitivity of VSBS and ASB for cardiac shunting diagnosis was 94.23% and 78.85%, respectively. The diagnostic sensitivity in the VSBS group was significantly higher than that in the ASB group (χ2 = 5.283, P = 0.022). The observed semiquantitative shunt grading suggests that the positive rate in the VSBS group was higher than that in the ASB group (Z = −1.998, P = 0.046). The use of vitamin B6 and sodium bicarbonate solution as a TTE contrast agent yielded a high sensitivity compared with ASB. However, further trials with large sample size are required to confirm this finding. PMID:29333447
Sarafraz-Yazdi, A; Mofazzeli, F; Es'haghi, Z
2009-07-15
A new and fast hollow fiber based liquid phase microextraction (HF-LPME) method using volatile organic solvents coupled with high-performance liquid chromatography (HPLC) was developed for determination of aromatic amines in the environmental water samples. Analytes including 3-nitroaniline, 3-chloroaniline and 4-bromoaniline were extracted from 6 mL basic aqueous sample solution (donor phase, NaOH 1 mol L(-1)) into the thin film of organic solvent that surrounded and impregnated the pores of the polypropylene hollow fiber wall (toluene, 20 microL), then back-extracted into the 6 mL acidified aqueous solution (acceptor phase, HCl 0.5 mol L(-1)) in the lumen of the two-end sealed hollow fiber. After the extraction, 5 microL of the acceptor phase was withdrawn into the syringe and injected directly into the HPLC system for the analysis. The parameters influencing the extraction efficiency including the kind of organic solvent and its volume, composition of donor and acceptor phases and the volume ratio between them, extraction time, stirring rate, salt addition and the effect of the analyte complexation with 18-crown-6 ether were investigated and optimized. Under the optimal conditions (donor phase: 6 mL of 1 mol L(-1) NaOH with 10% NaCl; organic phase: 20 microL of toluene; acceptor phase: 6 microL of 0.5 mol L(-1) HCl and 600 mmol L(-1) 18-crown-6 ether; pre-extraction and back-extraction times: 75 s and 10 min, respectively; stirring rate: 800 rpm), the obtained EFs were between 259 and 674, dynamic linear ranges were 0.1-1000 microg L(-1) (R>0.9991), and also the limits of detection were in the range of 0.01-0.1 micro gL(-1). The proposed procedure worked very well for real environmental water samples with microgram per liter level of the analytes, and good relative recoveries (91-102%) were obtained for the spiked sample solutions.
Sorption behaviour of perfluoroalkyl substances in soils.
Milinovic, Jelena; Lacorte, Silvia; Vidal, Miquel; Rigol, Anna
2015-04-01
The sorption behaviour of three perfluoroalkyl substances (PFASs), perfluorooctane sulfonic acid (PFOS), perfluorooctanoic acid (PFOA) and perfluorobutane sulfonic acid (PFBS), was studied in six soils with contrasting characteristics, especially in the organic carbon content. Sorption isotherms were obtained by equilibrating the soil samples with 0.01 mol L(-1) CaCl2 solutions spiked with increasing concentrations of the target PFAS. The sorption reversibility of PFASs was also tested for some of the samples. Liquid chromatography coupled to tandem mass spectrometry was used to quantify the target PFASs in the solutions. Both the Freundlich and linear models were appropriate to describe the sorption behaviour of PFASs in soils, and enabled us to derive solid-liquid distribution coefficients (Kd) for each compound in each soil. Kd values increased from 19 to 295 mL g(-1) for PFOS, from 2.2 to 38 mL g(-1) for PFOA and from 0.4 to 6.8 mL g(-1) for PFBS, and were positively correlated with the organic carbon content of the soil. KOC values obtained from the correlations were 710, 96 and 17 mL g(-1) for PFOS, PFOA and PFBS, respectively. Whereas Kd values decreased in the sequence PFOS>PFOA>PFBS, desorption yields were lower than 13% for PFOS, from 24 to 58% for PFOA, and from 32 to 60% for PFBS. This shows that the physicochemical characteristics of PFASs, basically their hydrophobicity, controlled their sorption behaviour in soils, with PFOS being the most irreversibly sorbed PFAS. Copyright © 2014 Elsevier B.V. All rights reserved.
Zereen, Fahmida; Yilmaz, Vedat; Arslan, Zikri
2013-01-01
A new chelating resin has been synthesized by immobilizing 4–(2–thiazolylazo) resorcinol (TAR) onto styrene divinlybenzene copolymer and examined for on-line solid phase extraction/preconcentration of Cd, Co, Cu, Ni, Pb and Zn in seawater and fish otoliths for determination by inductively plasma mass spectrometry (ICP-MS). A volume of 5.0 mL sample solution was loaded onto the mini column of TAR immobilized resin at 2.0 mL min−1 via a sequential injection system. The optimum pH for multielement preconcentration was around pH 5.5. Recoveries were better than 96% in artificial seawater. Elution was achieved with 1.0 mL of 0.75 mol L−1 HNO3. The resin possesses large sorption capacity ranging from 82.0 µmol g−1 for Pb to 319 µmol g−1 for Cu. The detection limits (3s) varied between 0.0016 µg L−1 (Cd) and to 0.015 µg L−1 (Zn) for preconcentration of 5.0 mL blank solutions (pH 5.5). Relative standard deviation (RSD)for three replicate runs was between 0.3% (Cd) and 6% (Zn) at 1.0 µg L−1 level. The procedure was validated by analysis of Nearshore Seawater certified reference material (CASS–4), and then successfully applied to the determination of the trace elements in fish otoliths (CRM 22) and in coastal seawater and estuarine water samples. PMID:24976635
NASA Astrophysics Data System (ADS)
Chadha, R.; Bali, A.
2016-05-01
Rapid, sensitive, cost effective and reproducible stability-indicating derivative spectrophotometric methods have been developed for the estimation of dronedarone HCl employing peak-zero (P-0) and peak-peak (P-P) techniques, and their stability-indicating potential assessed in forced degraded solutions of the drug. The methods were validated with respect to linearity, accuracy, precision and robustness. Excellent linearity was observed in concentrations 2-40 μg/ml ( r 2 = 0.9986). LOD and LOQ values for the proposed methods ranged from 0.42-0.46 μg/ml and 1.21-1.27 μg/ml, respectively, and excellent recovery of the drug was obtained in the tablet samples (99.70 ± 0.84%).
Flight Testing of the Forward Osmosis Bag for Water Recovery on STS-135
NASA Technical Reports Server (NTRS)
Roberts, Michael S.; Soler, Monica; Mortenson, Todd; McCoy, LaShelle; Woodward, Spencer; Levine, Howard G.
2011-01-01
The Forward Osmosis Bag (FOB) is a personal water purification device for recovery of potable liquid from almost any non-potable water source. The FOB experiment was flown as a sortie mission on STS-135/ULF7 using flight-certified materials and a design based on the X-Pack(TradeMark) from Hydration Technology Innovations (Albany, OR). The primary objective was to validate the technology for use under microgravity conditions. The FOB utilizes a difference in solute concentration across a selectively permeable membrane to draw water molecules from the non-potable water while rejecting most chemical and all microbial contaminants contained within. Six FOB devices were tested on STS-135 for their ability to produce a potable liquid permeate from a feed solution containing 500 mL potassium chloride (15 g/L) amended with 0.1% methyl blue dye (w:v) tracer against an osmotic gradient created by addition of 60 mL of concentrate containing the osmolytes fructose and glucose, and 0.01% sodium fluorescein (w:v) tracer. Three FOB devices were physically mixed by hand for 2 minutes by a crewmember after loading to augment membrane wetting for comparison with three unmixed FOB devices. Hydraulic flux rate and rejection of salt and dye in microgravity were determined from a 60-mL sample collected by the crew on orbit after 6 hours. Post-flight analysis of samples collected on orbit demonstrated that the Forward Osmosis Bag achieved expected design specifications in microgravity. The hydraulic flux rate of water across the membrane was reduced approximately 50% in microgravity relative to ground controls that generated an average of 50 mL per hour using the same water and osmolyte solutions. The membrane rejected both potassium and chloride at >92% and methyl blue dye at >99.9%. Physical mixing of the FOB during water recovery did not have any significant effect on either flux rate or rejection of solutes from the water solution. The absence of buoyancy-driven convection in microgravity suggests that mass transport was dominated by diffusion, slowing the rate of permeate production across the membrane. It is possible that a predicted reduction in concentration polarization at the membrane surface that may have acted to increase the rate of permeate production in microgravity was negligible under the described test conditions.
Tucker, S P; Reynolds, J M; Wickman, D C; Hines, C J; Perkins, J B
2001-06-01
Sampling and analytical methods were developed for commonly used chloroacetanilide, chlorotriazine, and 2,4-D herbicides in hand washes, on dermal patches, and in air. Eight herbicides selected for study were alachlor, atrazine, cyanazine, 2,4-dichlorophenoxyacetic acid (2,4-D), metolachlor, simazine, and two esters of 2,4-D, the 2-butoxyethyl ester (2,4-D, BE) and the 2-ethylhexyl ester (2,4-D, EH). The hand-wash method consisted of shaking the worker's hand in 150 mL of isopropanol in a polyethylene bag for 30 seconds. The dermal-patch method entailed attaching a 10-cm x 10-cm x 0.6-cm polyurethane foam (PUF) patch to the worker for exposure; recovery of the herbicides was achieved by extraction with 40 mL of isopropanol. The air method involved sampling with an OVS-2 tube (which contained an 11-mm quartz fiber filter and two beds of XAD-2 resin) and recovery with 2 mL of 10:90 methanol:methyl t-butyl ether. Analysis of each of the three sample types was performed by gas chromatography with an electron-capture detector. Diazomethane in solution was employed to convert 2,4-D as the free acid to the methyl ester in each of the three methods for ease of gas chromatography. Silicic acid was added to sample solutions to quench excess diazomethane. Limits of detection for all eight herbicides were matrix-dependent and, generally, less than 1 microgram per sample for each matrix. Sampling and analytical methods met NIOSH evaluation criteria for all herbicides in hand-wash samples, for seven herbicides in air samples (all herbicides except cyanazine), and for six herbicides in dermal-patch samples (all herbicides except cyanazine and 2,4-D). Speciation of 2,4-D esters and simultaneous determination of 2,4-D acid were possible without losses of the esters or of other herbicides (acetanilides and triazines) being determined.
Robeck, T R; O'Brien, J K
2004-05-01
Research was conducted to develop an effective method for cryopreserving bottlenose dolphin (Tursiops truncatus) semen processed immediately after collection or after 24-h liquid storage. In each of two experiments, four ejaculates were collected from three males. In experiment 1, three cryopreservation methods (CM1, CM2, and CM3), two straw sizes (0.25 and 0.5 ml), and three thawing rates (slow, medium, and fast) were evaluated. Evaluations were conducted at collection, prefreeze, and 0-, 3-, and 6-h postthaw. A sperm motility index (SMI; total motility [TM] x % progressive motility [PPM] x kinetic rating [KR, scale of 0-5]) was calculated and expressed as a percentage MI of the initial ejaculate. For all ejaculates, initial TM and PPM were greater than 85%, and KR was five. At 0-h postthaw, differences in SMI among cryopreservation methods and thaw rates were observed (P < 0.05), but no effect of straw size was observed. In experiment 2, ejaculates were divided into four aliquots for dilution (1:1) and storage at 4 degrees C with a skim milk- glucose or a N-tris(hydroxymethyl)methyl-2-aminoethane sulfonic acid (TES)-TRIS egg yolk solution and at 21 degrees C with a Hepes-Tyrode balanced salt solution (containing bovine albumin and HEPES) (TALP) medium or no dilution. After 24 h, samples were frozen and thawed (CM3, 0.5-ml straws, fast thawing rate) at 20 x 10(6) spermatozoa ml(-1) (low concentration) or at 100 x 10(6) spermatozoa ml(-1) (standard concentration). The SMI at 0-h postthaw was higher for samples stored at 4 degrees C than for samples stored at 21 degrees C (P < 0.001), and at 6-h postthaw, the SMI was higher for samples frozen at the standard concentration than for samples frozen at the low concentration (P < 0.05). For both experiments, acrosome integrity was similar across treatments. In summary, a semen cryopreservation protocol applied to fresh or liquid-stored semen maintained high levels of initial ejaculate sperm characteristics.
Avila-Vega, Dulce E; Alvarez-Mayorga, Beatriz; Arvizu-Medrano, Sofía M; Pacheco-Aguilar, Ramiro; Martínez-Peniche, Ramón; Hernández-Iturriaga, Montserrat
2014-11-01
The aim of this study was to generate information regarding the microbiological profile, including Salmonella and Listeria monocytogenes incidence, of hydroponically grown bell peppers and materials associated with their production in greenhouses located in Mexico. Samples of coconut fiber (24), knives (30), drippers (20), conveyor belts (161), pepper transportation wagons (30), air (178), water (16), nutrient solution for plant irrigation (78), and bell pepper fruits (528) were collected during one cycle of production (2009 to 2010) for the quantification of microbial indicators (aerobic plate counts [APC], molds, coliforms, and Escherichia coli) and the detection of Salmonella and L. monocytogenes. With regard to surfaces (conveyor belts and wagons) and utensils (knives and drippers), the APC, coliform, and mold counts ranged from 3.0 to 6.0, from 1.4 to 6.3, and from 3.6 to 5.2 log CFU/100 cm(2) or per utensil, respectively. The air in the greenhouse contained low median levels of APC (1.2 to 1.4 log CFU/100 liters) and molds (2.2 to 2.5 log CFU/100 liters). The median content of APC and coliforms in water were 0.5 log CFU/ml and 0.3 log MPN/100 ml, respectively. The median content of coliforms in nutrient solution ranged from 1.8 to 2.4 log MPN/100 ml, and E. coli was detected in 18 samples (range, <0.3 to 1.2 log MPN/100 ml). On bell pepper analyzed during the study, populations (median) of APC, coliforms, and molds were 5.4, 3.6, and 5.8 log CFU per fruit, respectively; E. coli was detected in 5.1% of the samples (range, 0.23 to 1.4 log MPN per fruit). Salmonella was isolated from only one sample (1.6%) of conveyor belt located at the packing area and in four bell pepper samples (3%). L. monocytogenes was not detected. This information could help producers to establish effective control measures to prevent the presence of foodborne pathogens in bell peppers based on a scientific approach.
Liu, Xiaofang; Zhou, Shu; Zhu, Quanfei; Ye, Yong; Chen, Huaixia
2014-09-01
A sample pretreatment method, solid-phase extraction combined with dispersive liquid-liquid microextraction (SPE-DLLME), was established for the sensitive determination of polycyclic aromatic hydrocarbons (PAHs) in smoked bacon samples. In the SPE-DLLME process, three PAHs including naphthalene (Naph), phenanthrene (Phen) and pyrene (Pyr) were extracted from samples and transferred into C18 SPE cartridge. The target analytes were subsequently eluted with 1.2 ml of acetonitrile-dichloromethane (5:1, v/v) mixture solution. The eluent was injected directly into the 5.0 ml ultrapure water in the subsequent DLLME procedure. The sedimented phase was concentrated under a gentle nitrogen flow to 120.0 µl. Finally, the analytes in the extraction solvent were determined by high-performance liquid chromatography with a ultra-violet detector. Some important extraction parameters affecting the performance, such as the sample solution flow rate, breakthrough volume, salt addition as well as the type and volume of the elution solvent were optimized. The developed method provided an ultra enrichment factors for PAHs ranged from 3478 to 3824. The method was applied for the selective extraction and sensitive determination of PAHs in smoked bacon samples. The limits of detection (S/N = 3) were 0.05, 0.01, 0.02 μg kg(-1) for Naph, Phen, Pyr, respectively. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Zahedi, Pegah; Davarani, Saied Saeed Hosseiny; Moazami, Hamid Reza; Nojavan, Saeed
2016-01-05
In this work, a simple and efficient surfactant assisted pulsed two-phase electromembrane extraction (SA-PEME) procedure combined with gas chromatography (GC) has been developed for the determination of alfentanil, sufentanil and methadone in various samples. It has been found that the addition of anionic surfactant causes the accumulation of the cationic analytes at the SLM/solution interface resulting in an easier transfer of the analytes into the organic phase. The method was accomplished with 1-octanol as the acceptor phase and supported liquid membrane (SLM) by means of an 80 V pulsed electrical driving force and the extraction time of 20 min. The model analytes were extracted from 3.0 mL sample solution (pH 4.0) containing 0.02% w/v surfactant (sodium dodecyl sulfate). The duty cycle of 92% and frequency of 0.357 Hz gave the best performance. Extraction recoveries in the range of 70.5-95.2% and satisfactory repeatability (7.6
Ultrafiltration and endotoxin removal from dialysis fluids.
Di Felice, A; Cappelli, G; Facchini, F; Tetta, C; Cornia, F; Aimo, G; Lusvarghi, E
1993-06-01
Biocompatibility in hemodialysis is now regarded as a multifactorial problem and dialysate represents a main risk. Pyrogenic fractions mostly coming from gram-negative bacteria easily pass through dialysis membrane, either by backdiffusion or by backfiltration, and induce blood cell activation. To demonstrate the long-term efficiency of a 2 m2 polyamide ultrafilter in producing a pyrogen free solution, we used an experimental circuit ultrafiltering for 240 hours (500 ml/min) a bicarbonate dialysate contaminated (5 to 48 EU/ml) by a Pseudomonas aeruginosa filtrate. The efficiency was monitored by LAL-test and IL-1 PBMC so to detect not only lipid A containing endotoxins but also other cytokines inducing bacterial fractions. At the post-ultrafilter sampling port the LAL-test was < 0.005 to 0.034 EU/ml; IL-1 PBMC was below the detection limit (20 pg/ml) being 27 to 63 pg/ml at the pre-ultrafilter level. Polyamide ultrafiltration represents an efficient system to obtain an endotoxin-free dialysate and a single filter works up to 240 hours.
NASA Astrophysics Data System (ADS)
Wu, Peng; Zhang, Yunchang; Lv, Yi; Hou, Xiandeng
2006-12-01
A simple, low cost and highly sensitive method based on cloud point extraction (CPE) for separation/preconcentration and thermospray flame quartz furnace atomic absorption spectrometry was proposed for the determination of ultratrace cadmium in water and urine samples. The analytical procedure involved the formation of analyte-entrapped surfactant micelles by mixing the analyte solution with an ammonium pyrrolidinedithiocarbamate (APDC) solution and a Triton X-114 solution. When the temperature of the system was higher than the cloud point of Triton X-114, the complex of cadmium-PDC entered the surfactant-rich phase and thus separation of the analyte from the matrix was achieved. Under optimal chemical and instrumental conditions, the limit of detection was 0.04 μg/L for cadmium with a sample volume of 10 mL. The analytical results of cadmium in water and urine samples agreed well with those by ICP-MS.
NASA Astrophysics Data System (ADS)
Yaqub, Asim; Isa, Mohamed Hasnain; Ajab, Huma; Kutty, S. R. M.; Ezechi, Ezerie H.; Farooq, Robina
2018-04-01
In this study IrO2 (Iridium oxide) was coated onto a titanium plate anode from a dilute (50 mg/10 ml) IrCl3×H2O salt solution. Coating was done at high temperature (550∘C) using thermal decomposition. Surface morphology and characteristics of coated surface of Ti/IrO2 anode were examined by FESEM and XRD. The coated anode was applied for electrochemical removal of organic pollutants from synthetic water samples in 100 mL compartment of batch electrochemical cell. About 50% COD removal was obtained at anode prepared with low Ir content solution while 72% COD removal was obtained with anode prepared at high Ir content. Maximum COD removal was obtained at 10 mA/cm2 current density.
Adam, Vojtech; Zitka, Ondrej; Dolezal, Petr; Zeman, Ladislav; Horna, Ales; Hubalek, Jaromir; Sileny, Jan; Krizkova, Sona; Trnkova, Libuse; Kizek, Rene
2008-01-01
Lactoferrin is a multifunctional protein with antimicrobial activity and others to health beneficial properties. The main aim of this work was to propose easy to use technique for lactoferrin isolation from cow colostrum samples. Primarily we utilized sodium dodecyl sulphate – polyacrylamide gel electrophoresis for isolation of lactoferrin from the real samples. Moreover we tested automated microfluidic Experion electrophoresis system to isolate lactoferrin from the collostrum sample. The well developed signal of lactoferrin was determined with detection limit (3 S/N) of 20 ng/ml. In spite of the fact that Experion is faster than SDS-PAGE both separation techniques cannot be used in routine analysis. Therefore we have tested third separation technique, ion exchange chromatography, using monolithic column coupled with UV-VIS detector (LC-UV-VIS). We optimized wave length (280 nm), ionic strength of the elution solution (1.5 M NaCl) and flow rate of the retention and elution solutions (0.25 ml/min and 0.75 ml/min. respectively). Under the optimal conditions the detection limit was estimated as 0.1 μg/ml of lactoferrin measured. Using LC-UV-VIS we determined that lactoferrin concentration varied from 0.5 g/l to 1.1 g/l in cow colostrums collected in the certain time interval up to 72 hours after birth. Further we focused on miniaturization of detection device. We tested amperometric detection at carbon electrode. The results encouraged us to attempt to miniaturise whole detection system and to test it on analysis of real samples of human faeces, because lactoferrin level in faeces is closely associated with the inflammations of intestine mucous membrane. For the purpose of miniaturization we employed the technology of printed electrodes. The detection limit of lactoferrin was estimated as 10 μg/ml measured by the screen-printed electrodes fabricated by us. The fabricated electrodes were compared with commercially available ones. It follows from the obtained results that the responses measured by commercial electrodes are app. ten times higher compared with those measured by the electrodes fabricated by us. This phenomenon relates with smaller working electrode surface area of the electrodes fabricated by us (about 50 %) compared to the commercial ones. The screen-printed electrodes fabricated by us were utilized for determination of lactoferrin faeces. Regarding to fact that sample of faeces was obtained from young and healthy man the amount of lactoferrin in sample was under the limit of detection of this method. PMID:27879717
Tokunaga, Hiroshi; Uchino, Tadashi
2005-01-01
Cyproheptadine hydrochloride (CH) is nominated as the prohibited ingredients in cosmetics in Japanese Pharmaceutical Affairs Act. So the analytical method for CH was investigated by HPLC. The lotion or milky lotion of 0.5 g was put into a 10-ml volumetric flask. After adding 1.0ml of CH solution at 50 microg/ml into the volumetric flask, the mixture was made up to 10ml with methanol as the test solution. Creams were procedured as follows; 0.5 g of cream was put into a 10-ml volumetric flask. After adding 1.0 ml of tetrahydrofuran into the volumetric flask, the mixture was stirred for several minutes and the ingredients of the creams were dissolved. After adding 1.0 ml of CH solution at 50 microg/ml into the volumetric flask, the mixture was made up to 10ml with methanol. This mixture was transferred to a centrifuging tube with a cap and then the tube was centrifuged for 5 minutes at 3000 rpm. The supernatant was used as the test solution. The test solution of 20 microl was analyzed by HPLC using the ODS column (CAPCELL PAK C18 column, 4.6 x 250 mm), the mixture of 1% acetic acid with 10 mmol/l sodium octanesulfonate and acetonitrile (11:9) and the detection wavelength of 286 nm. The working curve from 0.5 to 6.0 microg/ml showed a linear line between the concentrations of CH and the peak areas. There was no interference of peak of CH with the ingredients such as methylparaben, ethylparaben in the lotions, milky lotion and creams.
Code of Federal Regulations, 2013 CFR
2013-07-01
... buffer. 3.350-mL burette for 1.0 N sodium hydroxide. 3.4Magnetic stirrer and stir bars. 3.5250-mL beaker... N sodium hydroxide solution. 4.2Hydroxylamine hydrochloride solution, 100 grams per liter, pH... hydrochloric acid, and 0.1 N sodium hydroxide. 5.5Add 50 mL of the hydroxylamine hydrochloride solution...
Code of Federal Regulations, 2014 CFR
2014-07-01
... buffer. 3.350-mL burette for 1.0 N sodium hydroxide. 3.4Magnetic stirrer and stir bars. 3.5250-mL beaker... N sodium hydroxide solution. 4.2Hydroxylamine hydrochloride solution, 100 grams per liter, pH... hydrochloric acid, and 0.1 N sodium hydroxide. 5.5Add 50 mL of the hydroxylamine hydrochloride solution...
Two-phase electromembrane extraction followed by gas chromatography-mass spectrometry analysis.
Davarani, Saied Saeed Hosseiny; Morteza-Najarian, Amin; Nojavan, Saeed; Pourahadi, Ahmad; Abbassi, Mojtaba Beigzadeh
2013-02-01
A two-phase electromembrane extraction (EME) was developed and directly coupled with gas chromatography mass spectrometry (GC-MS) analysis. The proposed method was successfully applied to the simultaneous determination of imipramine, desipramine, citalopram and sertraline. The model compounds were extracted from neutral aqueous sample solutions into the organic phase filled in the lumen of the hollow fiber. This method was accomplished with 1-heptanol as organic phase, by means of 60 V applied voltage and with the extraction time of 15 min. Experiments reported recoveries in the range of 69-87% from 1.2 mL neutral sample solution. The compounds were quantified by GC-MS instrument, with acceptable linearity ranging from 1 to 500 ng mL(-1) (R(2) in the range of 0.989 to 0.998), and repeatability (RSD) ranging between 7.5 and 11.5% (n = 5). The estimated detection limits (S/N ratio of 3:1) were less than 0.25 ng mL(-1). This novel approach based on two-phase EME brought advantages such as simplicity, low-costing, low detection limit and fast extraction with a total analysis time less than 25 min. These experimental findings were highly interesting and demonstrated the possibility of solving ionic species in the organic phase at the presence of electrical potential. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Lehtimäki, Esa; Väisänen, Ari
2017-01-01
The digestion methods for the determination of As, Cd, Cr, Pb, Sb, Sn and Zn concentrations in plastic samples using microwave-assisted digestion (MW-AD) and small-size autoclave digestion was developed. The certified polyethylene, polypropylene, polyvinyl chloride and acrylonitrile butadiene styrene certified reference materials were used in order to find digestion method working properly for several sample matrices. Efficiency of the digestion methods was evaluated by analyzing the residual carbon in digests by TOC analyzer. MW-AD using a mixture of 7 mL of HNO3 and 3 mL of H2O2 as a digestion solution resulted in excellent recoveries for As, Cd, Pb, Sb and Zn, and were in the range of 92-107% for all the analytes except Pb in polyethylene material. Autoclave digestion using 5 mL of concentrated HNO3 as a digestion solution resulted in similar recoveries with the exception of a higher As recovery (98%). Tin recovery resulted in low level after both MW-AD and autoclave digestion. Autoclave digestion was further developed resulting in a partially open two-step digestion process especially for the determination of Sn and Cr. The method resulted in higher recoveries of Sn and Cr (87 and 76%) but with the lower concentration of easily volatile As, Cd and Sb.
Benett, William J.; Krulevitch, Peter A.
2001-01-01
A miniature connector for introducing microliter quantities of solutions into microfabricated fluidic devices. The fluidic connector, for example, joins standard high pressure liquid chromatography (HPLC) tubing to 1 mm diameter holes in silicon or glass, enabling ml-sized volumes of sample solutions to be merged with .mu.l-sized devices. The connector has many features, including ease of connect and disconnect; a small footprint which enables numerous connectors to be located in a small area; low dead volume; helium leak-tight; and tubing does not twist during connection. Thus the connector enables easy and effective change of microfluidic devices and introduction of different solutions in the devices.
The effect of endodontic materials on the optical density of dyes used in marginal leakage studies.
Kubo, Claudio Hideki; Valera, Marcia Carneiro; Gomes, Ana Paula Martins; Mancini, Maria Nadir Gasparoto; Camargo, Carlos Henrique Ribeiro
2008-01-01
The aim of this study was to determine the effect of the exposure of different endodontic materials to different dye solutions by evaluating the optical density of the dye solutions. Seventy-five plastic tubes were filled with one of the following materials: AH Plus, Sealapex, Portland cement, MTA (Angelus and Pro Root) and fifteen control plastic tubes were not. Each specimen of material and control was immersed in a container with 1 ml of each dye solution. A 0.1 ml-dye solution aliquote was removed before immersion and after 12, 24, 48 and 72 hours of each specimen immersion to record its optical density (OD) in a spectrophotometer. Statistical analysis was performed with ANOVA and Tukey tests (5%). No significant difference was found among any of the solution OD values for AH Plus cement. Portland cement promoted different OD values after 12 hours of immersion. MTA-Angelus cement presented different OD values only for 2% rhodamine B and the MTA-Pro Root cement presented different OD values in all 2% rhodamine B samples. Sealapex cement promoted a reduction in the India Ink OD values. Dye evaluation through OD seems to be an interesting method to select the best dye solution to use in a given marginal leakage study.
Hansen, T N; Carpenter, J F
1993-01-01
Differential scanning calorimetry and cryomicroscopy were used to investigate the effects of type I antifreeze protein (AFP) from winter flounder on 58% solutions of hydroxyethyl starch. The glass, devitrification, and melt transitions noted during rewarming were unaffected by 100 micrograms/ml AFP. Isothermal annealing experiments were undertaken to detect the effects of AFP-induced inhibition of ice crystal growth using calorimetry. A premelt endothermic peak was detected during warming after the annealing procedure. Increasing the duration or the temperature of the annealing for the temperature range from -28 and -18 degrees C resulted in a gradual increase in the enthalpy of the premelt endotherm. This transition was unaffected by 100 micrograms/ml AFP. Annealing between -18 and -10 degrees C resulted in a gradual decrease in the premelt peak enthalpy. This process was inhibited by 100 micrograms/ml AFP. Cryomicroscopic examination of the samples revealed that AFP inhibited ice recrystallization during isothermal annealing at -10 degrees C. Annealing at lower temperatures resulted in minimal ice recrystallization and no visible effect of AFP. Thus, the 100 micrograms/ml AFP to have a detectable influence on thermal events in the calorimeter, conditions must be used that result in significant ice growth without AFP and visible inhibition of this process by AFP. Images FIGURE 8 PMID:7690257
Priyank, Harsh; Pandey, Vinisha; Bagul, Abhishek; Majety, Kishore Kumar; Verma, Parul; Choudhury, Basanta Kumar
2017-03-01
Endodontic treatment removes all pathogens, such as Enterococcus faecalis from pulp and root canals. The aim of this study is to assess the usefulness of sodium hypo-chlorite (NaOCl) in removing E. faecalis from the root canal used with three different irrigation methods. This study was conducted on freshly extracted maxillary incisors. After biomechanical preparation, root canals were injected with E. faecalis. Three groups were made which contained 30 teeth in each group; 2 mL of NaOCl solution was used for irrigation followed by agitation with K-files in group I; 2 mL of NaOCl solution was used for irrigation and ultrasonic agitation was done in group II. In group III, an alternate irrigation with NaOCl and 3% hydrogen peroxide was done. The fourth group (control) was irrigated with sterile saline solution. E. fae-calis bacteria were sampled to the root canals with paper points and were transferred to tubes that contained 5 mL of brain heart infusion broth. Tubes were incubated and the presence of broth turbidity was suggestive of bacteria remaining in the root canal. All three groups showed no statistically significant difference. However, difference existed between experimental groups and control groups. The author concluded that all three methods of application of NaOCl were effective in disinfecting the root canal than the saline solution. No single irrigant has 100% efficiency. Thus by this study, a best irrigating solution with maximum properties can be established.
Urea encapsulation in modified starch matrix for nutrients retention
NASA Astrophysics Data System (ADS)
Naz, Muhammad Yasin; Sulaiman, Shaharin Anwar; Ariff, Mohd. Hazwan Bin Mohd.; Ariwahjoedi, Bambang
2014-10-01
It has been estimated that 20-70% of the used urea goes to the environment via leaching, nitrification and volatilization which not only harms the environment but also reduces the urea efficiency. By coating the urea granules, the farmers can achieve high urea performance through controlling the excess release of nitrogen. Up until now, different materials have been tested for nutrients retention. However, most of them are either expensive or unfriendly to the environment. Being cheap and biodegradable materials, the starches may also be used to coat the urea fertilizer for controlling the nutrients release. However, the pure starches do not meet the standards set by many industrial processes due to their slow tacking and too low viscosities and should be modified for getting smooth, compact and mechanically stronger coatings. In these studies, the tapioca starch was modified by reacting it with urea and different masses of borax. The prepared solutions were used to coat the urea granules of 3.45 mm average diameter. Different volumes (1, 1.5 and 2 mL) of each solution were used to coat 30 g of urea fluidized above the minimum level of fluidization. It was noticed that the coating thickness, percent coating, dissolution rate and percent release follow an increasing trend with an increase of solution volume; however, some random results were obtained while investigating the solution volume effects on the percent release. It was seen that the nutrients percent release over time increases with an increase in solution volume from 1 to 1.5 mL and thereafter reaches to a steady state. It confirms that the 1.5 mL of solution for 30 g urea samples will give the optimized coating results.
Functional Properties of Nonhuman Primate Antibody to Prophyromonas Gingivalis
1993-05-01
pg/ml of menadione , with reculturing performed at weekly intervals. For antigen preparation and viability assessment, the organisms were grown in...Mycoplasma Broth Base (MBB) supplemented with hemin (5 pg/ml) and menadione (1 pg/ml) under anaerobic conditions at 37*C. Each liter of media was...solution was mixed, autoclaved for 30 minutes and allowed to cool. Two ml of filter-sterilized menadione (0.5 mg/ml) was added to the solution. The media was
Moyakao, Khwankaew; Santaladchaiyakit, Yanawath; Srijaranai, Supalax; Vichapong, Jitlada
2018-04-11
In this work, we investigated montmorillonite for adsorption of neonicotinoid insecticides in vortex-assisted dispersive micro-solid phase extraction (VA-d-μ-SPE). High-performance liquid chromatography with photodiode array detection was used for quantification and determination of neonicotinoid insecticide residues, including thiamethoxam, clothianidin, imidacloprid, acetamiprid, and thiacloprid. In this method, the solid sorbent was dispersed into the aqueous sample solution and vortex agitation was performed to accelerate the extraction process. Finally, the solution was filtered from the solid sorbent with a membrane filter. The parameters affecting the extraction efficiency of the proposed method were optimized, such as amount of sorbent, sample volume, salt addition, type and volume of extraction solvent, and vortex time. The adsorbing results show that montmorillonite could be reused at least 4 times and be used as an effective adsorbent for rapid extraction/preconcentration of neonicotinoid insecticide residues. Under optimum conditions, linear dynamic ranges were achieved between 0.5 and 1000 ng mL -1 with a correlation of determination ( R² ) greater than 0.99. Limit of detection (LOD) ranged from 0.005 to 0.065 ng mL -1 , while limit of quantification (LOQ) ranged from 0.008 to 0.263 ng mL -1 . The enrichment factor (EF) ranged from 8 to 176-fold. The results demonstrated that the proposed method not only provided a more simple and sensitive method, but also can be used as a powerful alternative method for the simultaneous determination of insecticide residues in natural surface water and fruit juice samples.
NASA Astrophysics Data System (ADS)
López-García, Ignacio; Marín-Hernández, Juan José; Hernández-Córdoba, Manuel
2018-05-01
Vanadium (V) and vanadium (IV) in the presence of a small concentration of graphene oxide (0.05 mg mL-1) are quantitatively transferred to the coacervate obtained with Triton X-114 in a cloud point microextraction process. The surfactant-rich phase is directly injected into the graphite atomizer of an atomic absorption spectrometer. Using a 10-mL aliquot sample and 150 μL of a 15% Triton X-114 solution, the enrichment factor for the analyte is 103, which results in a detection limit of 0.02 μg L-1 vanadium. The separation of V(V) and V(IV) using an ion-exchanger allows speciation of the element at low concentrations. Data for seven reference water samples with certified vanadium contents confirm the reliability of the procedure. Several beer samples are also analyzed, those supplied as canned drinks showing low levels of tetravalent vanadium.
[Trapping techniques for Solenopsis invicta].
Liang, Xiao-song; Zhang, Qiang; Zhuang, Yiong-lin; Li, Gui-wen; Ji, Lin-peng; Wang, Jian-guo; Dai, Hua-guo
2007-06-01
A field study was made to investigate the trapping effects of different attractants, traps, and wind directions on Solenopsis invicta. The results showed that among the test attractants, TB1 (50 g fishmeal, 40 g peptone, 10 ml 10% sucrose water solution and 20 ml soybean oil) had the best effect, followed by TB2 (ham), TB6 (100 g cornmeal and 20 ml soybean oil) and TB4 (10 ml 10% sucrose water solution, 100 g sugarcane powder and 20 ml soybean oil), with a mean capture efficiency being 77.6, 58.7, 29 and 7.7 individuals per trap, respectively. No S. invicta was trapped with TB3 (10 ml 10% sucrose water solution, 100 g cornmeal and 20 ml soybean oil) and TB5 (honey). Tube trap was superior to dish trap, with a trapping efficiency of 75.2 and 35 individuals per trap, respectively. The attractants had better effects in leeward than in windward.
Wang, Qing; Zhao, Hua; Xi, Cunxian; Wang, Guomin; Chen, Dongdong; Ding, Shijia
2014-01-01
An immunoaffinity column clean-up and LC-MS/MS method was successfully developed for simultaneous determination of chloramphenicol, zearalanone, α-zearalanol, β-zearalanol, zearalenone, α-zearalenol and β-zearalenol in pig muscle. The sample was extracted with diethyl ether after enzymatic digestion by β-glucuronidase/sulfatase. The extracted solution was evaporated to dryness and the residue was then dissolved in 1 ml of 50% acetonitrile solution. After filtration and dilution with phosphate buffer solution (PBS), the reconstituted solution was cleaned-up with an IAC-CZ immunoaffinity column and then analysed by HPLC-MS/MS. The established method were validated by linearity (r ≥ 0.9990), precision (RSD ≥ 2.9%), average recovery (74.5-105.0%) and limit of detection (0.04-0.10 μg kg(-1)). The developed method is rapid, reliable, sensitive, accurate and has good applicability for real samples.
Fakhari, Ali Reza; Tabani, Hadi; Nojavan, Saeed
2013-07-01
A simple and highly sensitive method that involves miniaturized hollow fibre assisted liquid-phase microextraction with gas chromatography-flame ionization detector was developed for the determination of trace concentration of sufentanil and alfentanil in biological samples. These drugs were extracted from 5 ml of aqueous solution with pH 10.0 into an organic extracting solvent (1-octanol) impregnated in the pores and lumen of a hollow fibre. After extraction for a prescribed time, 2.0 µl of the extraction solvent was injected directly in to the GC injection port. Under the optimized conditions, (1-octanol as extracting solvent, stirring rate of 700 rpm, 15% (w/v) salt addition, pH 10.0 and 25 min sampling time at 50 °C) large enrichment factors of 535 and 420 were achieved for sufentanil and alfentanil, respectively. Dynamic linear ranges were in the range of 0.05 to 500 ng/ml for sufentanil and 0.1 to 500 ng/ml for alfentanil. Limits of detection 0.01 and 0.02 ng/ml were obtained for sufentanil and alfentanil, respectively. The percent relative intra-day and inter-day standard deviations were found to be less than 8.4% (n = 5). Finally, this method was successfully applied for the separation, preconcentration and determination of trace concentration of sufentanil and alfentanil in plasma and urine samples. Copyright © 2012 John Wiley & Sons, Ltd.
Detection of magnetic nanoparticles with a large scale AC superconducting susceptometer
NASA Astrophysics Data System (ADS)
Hincapie Ladino, E. A.; Zufelato, N.; Bakuzis, A. F.; Oliveira Carneiro, A. A.; Covas, D. T.; Baffa, O.
2017-08-01
Magnetic nanoparticles (MNPs) are being used in several applications in medicine such as hyperthermia, magnetic particle imaging, in vitro and in vivo bioassay, and still there are many other possibilities for use of these particles to come as research progress in this field. One crucial step of its use is the detection of these particles when present in a certain tissue. For in vitro bioassay, the sample can be harvested and placed inside the detector in optimal conditions to favor sensitivity. However, for in vivo human measurements the system must be noninvasive and conform to the anatomic restrictions requiring sensitive detectors and dedicated setups. In this study, we detect nanoparticles with an AC biosusceptometer having an excitation homogeneous magnetic field with 145 μT, provided by a set of rectangular large Rubens coils driven at 10 Hz. The magnetization induced in the sample was detected by a second-order axial gradiometer (20 mm in diameter and 40 mm of baseline) coupled to an RF Superconducting Quantum Interference Device (SQUID) model 330X (BTi). The MNPs used were manganese ferrite-based surface-coated with citric acid ({{M}}{{n}}{{F}}{{{e}}}2{{{O}}}4-{{C}}{{i}}{{t}}{{r}}{{a}}{{t}}{{e}}), dissolved in water at various concentrations. The colloid is stable at physiological conditions. X-ray diffraction confirmed the spinel structure and using Scherrer’s relation revealed a particle size of 17.3 nm. The magnetization curve showed a typical superparamagnetic behavior with a specific saturation magnetization of 51.2 emu g-1. The stock solution of nanoparticles had a concentration of 23.17 mg ml-1, corresponding to 1.7 × 1015 NPs ml-1. Measurements were made in a volume of 30 ml with 20 × 103-100 × 103 dilutions of the stock solution of nanoparticles and performed at distances of 1.1, 1.5 and 2.5 cm from the top of the sample vial to the closest coil of the gradiometer. The limits of detection were 8.1 × 109 NP ml-1, 9.5 × 109 NP ml-1 and 11.0 × 109 NP ml-1 for the distances above. These values suggest that the technique might have interesting applications in the real-time in vivo detection of nanoparticles after systemic injections. The present setup can be improved by using more sensitive SQUID sensors and less noisy cryostats.
Nira acidity and antioxidant activity of Palm sugar in Sumowono Village
NASA Astrophysics Data System (ADS)
Winarni, Sri; Arifan, Fahmi; Wisnu Broto, RTD.; Fuadi, Ariza; Alviche, Lola
2018-05-01
The palm sugar not only has potential as natural sweetener but also has antioxidant. The purpose of this study was to analyze antioxidant and pH of the nira in palm sugar. The sample in this study was palm sugar from 6 different production sites. Test of antioxidant activity used DPPH method (1.1-diphenyl-2-picrylhydrazyl) with a wavelength of 517 nm. The value of absorbance solution was measured using spectrophotometry and the value of effective concentration (IC50) was counted. The pH test was measured using a pH meter. Pearson’s correlation test revealed r=-0.045 with significant value 0.932 (>0.005). There was no correlation between pH value and antioxidant activity of palm sugar. IC50 value of palm sugar in Sumowono village revealed that it had a strong antioxidant activity (50 μg/ml - 100 μg/ml) that is 74,73 μg/ml 83.94 μg/ml 82.31 μg/ml 83.94 μg/ml 86.10 μg/ml 82.13 μg/ml 89.17 μg/ml 89.71 μg/ml 89.17 μg/ml and 84.84 μg/ml). Lower IC50 values indicate higher antioxidant activity. Palm sugar with the best antioxidant activity came from the production sites which had IC50 values of 74.73 μg/ml. Potential antioxidants can be optimized by making improvements to the processing system.
21 CFR 522.900 - Euthanasia solution.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Euthanasia solution. 522.900 Section 522.900 Food... Euthanasia solution. (a) Specifications. Each milliliter (mL) of solution contains: (1) 390 milligrams (mg.... For humane, painless, and rapid euthanasia. (2) Amount. One mL per 10 pounds of body weight. (3...
21 CFR 522.900 - Euthanasia solution.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 6 2014-04-01 2014-04-01 false Euthanasia solution. 522.900 Section 522.900 Food... Euthanasia solution. (a) Specifications. Each milliliter (mL) of solution contains: (1) 390 milligrams (mg.... For humane, painless, and rapid euthanasia. (2) Amount. One mL per 10 pounds of body weight. (3...
21 CFR 522.900 - Euthanasia solution.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Euthanasia solution. 522.900 Section 522.900 Food... Euthanasia solution. (a) Specifications. Each milliliter (mL) of solution contains: (1) 390 milligrams (mg.... For humane, painless, and rapid euthanasia. (2) Amount. One mL per 10 pounds of body weight. (3...
21 CFR 522.900 - Euthanasia solution.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Euthanasia solution. 522.900 Section 522.900 Food... Euthanasia solution. (a) Specifications. Each milliliter (mL) of solution contains: (1) 390 milligrams (mg.... For humane, painless, and rapid euthanasia. (2) Amount. One mL per 10 pounds of body weight. (3...
21 CFR 522.900 - Euthanasia solution.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Euthanasia solution. 522.900 Section 522.900 Food... Euthanasia solution. (a) Specifications. Each milliliter (mL) of solution contains: (1) 390 milligrams (mg.... For humane, painless, and rapid euthanasia. (2) Amount. One mL per 10 pounds of body weight. (3...
[Effects of antiseptic on the analysis of greenhouse gases concentrations in lake water].
Xiao, Qi-Tao; Hu, Zheng-Hu; James, Deng; Xiao, Wei; Liu, Shou-Dong; Li, Xu-Hui
2014-01-01
To gain insight into antiseptic effects on the concentrations of CO2, CH4, and N2O in lake water, antisepetic (CuSO4 and HgCl2) were added into water sample, and concentrations of greenhouse gases were measured by the gas chromatography based on water equilibrium method. Experiments were conducted as following: the control group without antisepetic (CK), the treatment group with 1 mL CuSO4 solution (T1), the treatment group with 5 mL CuSO4 solution (T2), and the treatment group with 0.5 mL HgCl2 solution (T3). All groups were divided into two batches: immediately analysis (I), and after 2 days analysis (II). Results showed that CuSO4 and HgCl2 significantly increased CO2 concentration, the mean CO2 concentration (Mco2) of CK (I) and CK (II) were (11.5 +/- 1.47) micromol x L(-1) and (14.38 +/- 1.59) micromol x L(-1), respectively; the Mco2 of T1 (I) and T1 (II) were (376 +/- 70) micromol x L(-1) and (448 +/- 246.83) micromol x L(-1), respectively; the Mco2 of T2 (I) and T2 (II) were (885 +/- 51.53) micromol x L(-1) and (988.83 +/- 101.96) micromol x L(-1), respectively; the Mco2 of T3 (I) and T3 (II) were (287.19 +/- 30.01) micromol x L(-1) and (331.33 +/- 22.06) micromol x L(-1), respectively. The results also showed that there was no difference in CH4 and N2O concentrations among treatments. Water samples should be analyzed as soon as possible after pretreatment. Our findings suggest that adding antiseptic may lead an increase in CO2 concentration.
Zhang, Yantu; Zhang, Zhujun; Qi, Guangcai; Sun, Yonghua; Wei, Yue; Ma, Hongyan
2007-01-23
The determination of indomethacin (INM) in pharmaceutical and biological samples by means of high-performance liquid chromatography (HPLC) with in situ electrogenerated Mn(III) chemiluminescence (CL) detection was proposed. The method was based on the direct CL reaction of INM and Mn(III), which was in situ electrogenerated by constant current electrolysis. The chromatographic separation was carried out on Nucleosil RP-C(18) column (250 mm x 4.6 mm; i.d., 5 microm; pore size, 100 A) at 20 degrees C. The mobile phase consisted of methanol:water:acetic acid=67:33:0.1 solution. At a flow rate of 1.0 mL min(-1), the total run time was 10 min. The effects of several parameters on the HPLC resolution and CL emission were studied systematically. Under the optimal conditions, a linear range from 0.01 to 10 microg mL(-1)(R(2)=0.9991), and a detection limit of 8 ng mL(-1) (signal-to-noise ratio=3) for INM were achieved. The relative standard deviations (R.S.D.) for 0.1 microg mL(-1) INM were 2.2% within a day (n=11) and 3.0% on 5 consecutive days (n=6), respectively. The recovery of INM from urine samples was more than 92%. The applicability of the method for the analysis of pharmaceutical and biological samples was examined.
Qin, Wen-xia; Gong, Qi; Li, Min; Deng, Li-xin; Mo, Li-shu; Li, Yan-lin
2015-04-01
Determination of arsenic in pure aluminum by inductively coupled plasma atomic emission spectrometry was interfered by aluminum matrix. The experiment showed that when the mass concentration of Al was greater than or equal to 5 000 times the As in the test solution, the measurement error was greater than 5%. In order to eliminate the interference, strong acid cation exchange fiber (SACEF) was used as solid phase extraction agent to adsorb Al(3+). The extraction conditions included amount of SACEF, extraction time, temperature and pH were investigated. The optimal extraction conditions were that 0.9000 g SACEF was used to extract the aluminum from the sample solution of pH 2.0 at 55 °C for 5 min with the ultrasonic assist, and in this case, the arsenic in the form of arsenic acid was not extracted and left in the solution for the determination. The results showed that after treating 10. 00 mL test solution containing 1.00 µg arsenic and 20.0 mg aluminum, arsenic did not lose. The mass concentration of residual aluminum in the raffinate was about 2,000 times the As, which had not interfered the determination of arsenic. The detection limit (3 s) was 0.027 µg · mL(-1) and quantification limit (10 s) was 0.0091 µg · mL(-1). The proposed method was successfully applied to the separation and determination of arsenic in the synthetic samples, the aluminum cans and the barbecue aluminum foil. Recovery was in the range of 98.3%-105% and RSD (n = 3) was in the range of 0.1%-4.3%. The results showed that the content of arsenic in the aluminum cans and the aluminum barbecue foil was below the limited value of national standard (GB/T 3190-2008).
27 CFR 21.119 - Nicotine solution.
Code of Federal Regulations, 2012 CFR
2012-04-01
..., with 50 ml of a standard color solution containing 5 grams of CuSO4·5H2 O, C.P. in 100 ml of water. The... H2SO4 using rosolic acid or methyl red as indicator. Not less than 23.2 ml should be required for...
27 CFR 21.119 - Nicotine solution.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., with 50 ml of a standard color solution containing 5 grams of CuSO4·5H2 O, C.P. in 100 ml of water. The... H2SO4 using rosolic acid or methyl red as indicator. Not less than 23.2 ml should be required for...
27 CFR 21.119 - Nicotine solution.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., with 50 ml of a standard color solution containing 5 grams of CuSO4·5H2 O, C.P. in 100 ml of water. The... H2SO4 using rosolic acid or methyl red as indicator. Not less than 23.2 ml should be required for...
27 CFR 21.119 - Nicotine solution.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., with 50 ml of a standard color solution containing 5 grams of CuSO4·5H2 O, C.P. in 100 ml of water. The... H2SO4 using rosolic acid or methyl red as indicator. Not less than 23.2 ml should be required for...
27 CFR 21.119 - Nicotine solution.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., with 50 ml of a standard color solution containing 5 grams of CuSO4·5H2 O, C.P. in 100 ml of water. The... H2SO4 using rosolic acid or methyl red as indicator. Not less than 23.2 ml should be required for...
Chromium speciation in environmental samples using a solid phase spectrophotometric method
NASA Astrophysics Data System (ADS)
Amin, Alaa S.; Kassem, Mohammed A.
2012-10-01
A solid phase extraction technique is proposed for preconcentration and speciation of chromium in natural waters using spectrophotometric analysis. The procedure is based on sorption of chromium(III) as 4-(2-benzothiazolylazo)2,2'-biphenyldiol complex on dextran-type anion-exchange gel (Sephadex DEAE A-25). After reduction of Cr(VI) by 0.5 ml of 96% concentrated H2SO4 and ethanol, the system was applied to the total chromium. The concentration of Cr(VI) was calculated as the difference between the total Cr and the Cr(III) content. The influences of some analytical parameters such as: pH of the aqueous solution, amounts of 4-(2-benzothiazolylazo)2,2'-biphenyldiol (BTABD), and sample volumes were investigated. The absorbance of the gel, at 628 and 750 nm, packed in a 1.0 mm cell, is measured directly. The molar absorptivities were found to be 2.11 × 107 and 3.90 × 107 L mol-1 cm-1 for 500 and 1000 ml, respectively. Calibration is linear over the range 0.05-1.45 μg L-1 with RSD of <1.85% (n = 8.0). Using 35 mg exchanger, the detection and quantification limits were 13 and 44 ng L-1 for 500 ml sample, whereas for 1000 ml sample were 8.0 and 27 ng L-1, respectively. Increasing the sample volume can enhance the sensitivity. No considerable interferences have been observed from other investigated anions and cations on the chromium speciation. The proposed method was applied to the speciation of chromium in natural waters and total chromium preconcentration in microwave digested tobacco, coffee, tea, and soil samples. The results were simultaneously compared with those obtained using an ET AAS method, whereby the validity of the method has been tested.
Ghaedi, M; Tavallali, H; Montazerozohori, M; Zahedi, E; Amirineko, M; Khodadoust, S; Karimipour, G
2012-11-01
In this work, two N/S-containing chelating agents 2-(4-methoxybenzylideneamino)thiophenol (2-4-MBAT) and 2-(4-chlorobenzylideneamino) benzenethiol (2-4-CBABT) were synthesized as new sorbents and were used for preconcentration of Zn(2+) and Cu(2+) ions in food and vegetable samples. In the proposed procedure, the trace amount of Zn(2+) and Cu(2+) ions from 250 mL of sample solution at pH = 5.0 was preconcentrated by 1 g of activated carbon (AC) loaded with 15 mg of 2-4-MBAT and 2-4-CBABT separately. The breakthrough volumes (maximum sample volume that their metal ions quantitatively can be enriched) for solid-phase extraction (SPE) procedure based on the AC modified with 2-4-MBAT and 2-4-CBABT were 800 and 750 mL, respectively. The sorbed Zn(2+) and Cu(2+) ions were efficiently eluted by 8 mL of 4 mol L(-1) HNO(3) and preconcentration factor of 112.5 and 93.7 and experimental enhancement factor of 30 and 35 ions were obtained for Zn(2+) and Cu(2+), respectively. The application of this enrichment procedure allowed the extraction of trace metal ions with recoveries exceeding of 90%.
Uremic Solutes in Chronic Kidney Disease and Their Role in Progression.
van den Brand, Jan A J G; Mutsaers, Henricus A M; van Zuilen, Arjan D; Blankestijn, Peter J; van den Broek, Petra H; Russel, Frans G M; Masereeuw, Rosalinde; Wetzels, Jack F M
2016-01-01
To date, over 150 possible uremic solutes have been listed, but their role in the progression of CKD is largely unknown. Here, the association between a selected panel of uremic solutes and progression in CKD patients was investigated. Patients from the MASTERPLAN study, a randomized controlled trial in CKD patients with a creatinine clearance between 20 and 70 ml/min per 1.73m2, were selected based on their rate of eGFR decline during the first five years of follow-up. They were categorized as rapid (decline >5 ml/min per year) or slow progressors. Concentrations of eleven uremic solutes were obtained at baseline and after one year of follow-up. Logistic regression was used to compare the odds for rapid to slow progression by uremic solute concentrations at baseline. Variability in uremic solute levels was assessed using scatter plots, and limits of variability were calculated. In total, 40 rapidly and 40 slowly progressing patients were included. Uremic solutes were elevated in all patients compared to reference values for healthy persons. The serum levels of uremic solutes were not associated with rapid progression. Moreover, we observed substantial variability in solute levels over time. Elevated concentrations of uremic solutes measured in this study did not explain differences in rate of eGFR decline in CKD patients, possibly due to lack of power as a result of the small sample size, substantial between patient variability, and variability in solute concentrations over time. The etiology of intra-individual variation in uremic solute levels remains to be elucidated.
Fort Ord Groundwater Remediation Studies, 2002 - 2005
2006-08-01
Groundwater was also directly sampled from a well OU1-36 with a bailer using an acid - cleaned bailer to determine whether comparable levels of trace...collected for the analysis of total chromium. The total chromium and Cr(VI) samples were collected in acid -clean low density polyethylene (LDPE) bottles...and 69Ga to be used as an internal standard. Acetic acid /ammonia buffer solution was prepared by slow addition of 15 mL of aqueous ammonia (20–22
Kassem, Mohammed A; Amin, Alaa S
2015-02-05
A new method to estimate rhodium in different samples at trace levels had been developed. Rhodium was complexed with 5-(4'-nitro-2',6'-dichlorophenylazo)-6-hydroxypyrimidine-2,4-dione (NDPHPD) as a complexing agent in an aqueous medium and concentrated by using Triton X-114 as a surfactant. The investigated rhodium complex was preconcentrated with cloud point extraction process using the nonionic surfactant Triton X-114 to extract rhodium complex from aqueous solutions at pH 4.75. After the phase separation at 50°C, the surfactant-rich phase was heated again at 100°C to remove water after decantation and the remaining phase was dissolved using 0.5mL of acetonitrile. Under optimum conditions, the calibration curve was linear for the concentration range of 0.5-75ngmL(-1) and the detection limit was 0.15ngmL(-1) of the original solution. The enhancement factor of 500 was achieved for 250mL samples containing the analyte and relative standard deviations were ⩽1.50%. The method was found to be highly selective, fairly sensitive, simple, rapid and economical and safely applied for rhodium determination in different complex materials such as synthetic mixture of alloys and environmental water samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Kirkham, Kylian; Munson, Jessica M; McCluskey, Susan V; Graner, Kevin K
2017-01-01
The stability of dalteparin 1,000 units/mL in 0.9% sodium chloride for injection stored in polypropylene syringes under refrigeration was examined. Dalteparin 1,000-units/mL syringes were prepared by adding 9 mL of 0.9% sodium chloride for injection to 1 mL of dalteparin sodium 10,000 unit/mL from commercial single-use syringes. Compounded solutions in 0.5-mL aliquots were transferred to 1-mL polypropylene syringes and sealed with a Luer lock tip cap and stored at refrigerated temperatures (2°C to 8°C) with ambient fluorescent light exposure. Syringes from three batches of dalteparin 1,000 units/mL were potency tested in duplicate by a stability-indicating high-performance liquid chromatography assay using a 0.5-mL sample at specified intervals. Visual and pH testing were performed on each batch. Samples were visually inspected for container integrity, color, and clarity. Samples for pH testing were prepared using a 1:1 dilution of dalteparin 1,000 units/mL in sterile water for injection and underwent duplicate analysis at each time point. High-performance liquid chromatography analyses showed a remaining percent of the initial dalteparin content at day 30 of 94.88% ± 2.11%. Samples remained colorless and clear with no signs of container compromise and no visual particulate matter at each time point. Throughout the 30-day study period, pH values remained within 0.3-pH units from the initial value of 5.84. Dalteparin 1,000 unit/mL in 0.9% sodium chloride for injection, packaged in 1-mL polypropylene syringes was stable for at least 30 days while stored at refrigerated conditions with ambient fluorescent light exposure. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Hosseini, Mohammad Saeid; Hashemi-Moghaddam, Hamid; Kardan-Moghaddam, Gholamreza
2007-01-01
A simple method for separation/preconcentration and determination of Ag(I) in aqueous samples is described. The method is based on formation of an ion-associate between Ag(I)-iodide complex and ferroin, which can be floated at the interface of the aqueous/n-heptane phases. The flotation process was carried out using 500-ml aliquot of the aqueous solution and the floated layer was dissolved in 5 ml of 1 M HNO3 containing methanol (50% v/v) as the solvent. The Ag(I) content was then determined by flame atomic absorption spectrometry (FAAS). The method so could be considered as an enrichment process, was achieved to a quantitative feature, when the pH of the solution was adjusted to 4 and the concentrations of iodide and ferroin were about 3.2 x 10(-4) M and 6.25 x 10(-5) M, respectively. The LOD and RSD (n = 7) were obtained 1.0 x 10(-8) M and 2.4%, respectively. It was found that a large number of cations and anions even at high considerably foreign ion/Ag(I) ratios were not interfered. The method was applied satisfactorily to recovery of Ag(I) from different aqueous samples.
Adsorption of NO on alumina-supported oxides and oxide-hydroxides of manganese.
Spasova, I; Nikolov, P; Mehandjiev, D
2005-10-15
The adsorption capacity for NO of alumina-supported oxides and oxide-hydroxides of manganese have been studied. Two series of samples have been prepared by precipitation on gamma-alumina and appropriate thermal treatment. The samples have been characterized by adsorption methods, magnetic methods, electronic paramagnetic resonance (EPR), transient response technique, and temperature-programmed desorption (TPD). The influence of the concentration of the initial manganese-containing solution has been investigated. The sample, prepared with a solution with Mn concentration of 4 g/100 ml, has been shown to be the best adsorbent for NO under the conditions of the experiment. It has been found that the presence mainly of Mn3+ ions on the surface of the support is probably responsible for the enhanced adsorption capacity.
Semi-microdroplet assay for cell adhesion molecules. M.S. Thesis
NASA Technical Reports Server (NTRS)
Tawa, Lawrence Shinzo
1988-01-01
A new cell-to-cell adhesion assay was devised. Using dissociated embryos of the sea urchin, this procedure involves rotating a 0.100 ml suspension of single cells with 0.100 ml of the solution to be tested in the bulb portion of a transfer pipet with the tip removed. After 1 hour of rotation at 60 rpm at 15 C, the contents of each bulb were transferred into individual wells of a 96 well flat bottom plate. After the plate was incubated for 1 hour at 15 C, black and white photographs were taken with a 35 mm camera attached to an inverted photomicroscope. Examining a proof sheet of the negatives directly allowed a rapid evaluation of suspected cell adhesion promoting factors. A ranking system was used to evaluate all samples. The assay was tested by examining the effect of specific solutions on the aggregation of single cells obtained from dissociated 23 hour embryos.
Nojavan, Saeed; Fakhari, Ali Reza
2010-10-01
Electro membrane extraction as a new microextraction method was applied for the extraction of amlodipine (AM) enantiomers from biological samples. During the extraction time of 15 min, AM enantiomers migrated from a 3 mL sample solution, through a supported liquid membrane into a 20 μL acceptor solution presented inside the lumen of the hollow fiber. The driving force of the extraction was 200 V potential, with the negative electrode in the acceptor solution and the positive electrode in the sample solution. 2-Nitro phenyl octylether was used as the supported liquid membrane. Using 10 mM HCl as background electrolyte in the sample and acceptor solution, enrichment up to 124 times was achieved. Then, the extract was analyzed using CD modified CE method for separation of AM enantiomers. Best results were achieved using a phosphate running buffer (100 mM, pH 2.0) containing 5 mM hydroxypropyl-α-CD. The range of quantitation for both enantiomers was 10-500 ng/mL. Intra- and interday RSD (n=6) were less than 14%. The limits of quantitation and detection for both enantiomers were 10 and 3 ng/mL respectively. Finally, this procedure was applied to determine the concentration of AM enantiomers in plasma and urine samples.
Amin, Alaa S
2014-01-01
Solid-phase spectrophotometry was applied to determination of trace amounts of selenium (Se) in water, soil, plant materials, human hair, and a cosmetic preparation (lipstick). Se(IV) was sorbed in a dextran type lipophilic gel as a complex with 2,3-dichloro-6-(2,7-dihydroxy-naphthylazo)quinoxaline (DCDHNAQ), whereas Se(VI) was determined after boiling in HCI for 10 min to convert Se(VI) to Se(IV). Resin phase absorbances at 588 and 800 nm were measured directly, which allowed the determination of Se in the range of 0.2-3.3 microg/L with an RSD of 1.22%. The influences of analytical parameters including pH of the aqueous solution, amounts of DCDHNAQ, and sample volume were investigated. The molar absorptivities were found to be 1.09 x 10(6), 4.60 x 10(6), and 1.23 x 10(7) L/mol cm for 100, 500, and 1000 mL, respectively. The LOD and LOQ of the 500 mL sample method were 110 and 360 ng/L, respectively, when using 50 mg dextran type lipophilic gel. For a 1000 mL sample, the LOD and LOQ were 60 and 200 ng/L, respectively, using 50 mg of the exchanger. Increasing the sample volume enhanced the sensitivity. No considerable interferences were observed from other investigated anions and cations on the Se determination.
Improved spectrophotometric cell for hydrothermal solutions
Susak, N.J.; Crerar, D.A.; Forseman, T.C.; Haas, J.L.
1981-01-01
A simple, inexpensive spectrophotometric cell was designed for use with aqueous solutions for which temperature is a maximum of 325??C and pressure, 28 MPa. The cell has an internal volume of 5 ml and a path length of 1.31 cm. Each furnace assembly is 120 mm in diameter ?? 150 mm high and will fit into most commercial spectrophotometers. Temperature is controlled by a standard set-point controller and a balancing circuit that is used to maintain the temperature of the sample and reference cell within 1??C of each other at any temperature.
Method of high-precision microsampled blood and plasma mass densitometry
NASA Technical Reports Server (NTRS)
Hinghofer-Szalkay, H.
1986-01-01
The reliability of the mechanical oscillator technique for blood and plasma density measurements on samples of volumes less than 0.1 ml is examined, and a precision of 0.001 g/l is found if plasma-isodensic heparin solution and siliconized densitometers are employed. Sources of measurement errors in the density determinations include storage of plasma samples, inhomogeneity of blood samples, and density reading before adequate temperature equilibration. In tests of plasma sample storage, the best reproducibility was obtained with samples kept at 4 C. Linear correlations were found between plasma density and plasma protein concentration, blood density and blood hemoglobin concentration, and erythrocyte density and MCHC.
NASA Astrophysics Data System (ADS)
Wang, Xun; Ghidaoui, Mohamed S.
2018-07-01
This paper considers the problem of identifying multiple leaks in a water-filled pipeline based on inverse transient wave theory. The analytical solution to this problem involves nonlinear interaction terms between the various leaks. This paper shows analytically and numerically that these nonlinear terms are of the order of the leak sizes to the power two and; thus, negligible. As a result of this simplification, a maximum likelihood (ML) scheme that identifies leak locations and leak sizes separately is formulated and tested. It is found that the ML estimation scheme is highly efficient and robust with respect to noise. In addition, the ML method is a super-resolution leak localization scheme because its resolvable leak distance (approximately 0.15λmin , where λmin is the minimum wavelength) is below the Nyquist-Shannon sampling theorem limit (0.5λmin). Moreover, the Cramér-Rao lower bound (CRLB) is derived and used to show the efficiency of the ML scheme estimates. The variance of the ML estimator approximates the CRLB proving that the ML scheme belongs to class of best unbiased estimator of leak localization methods.
ERIC Educational Resources Information Center
Nyasulu, Frazier; Barlag, Rebecca
2011-01-01
The well-known colorimetric determination of the equilibrium constant of the iron(III-thiocyanate complex is simplified by preparing solutions in a cuvette. For the calibration plot, 0.10 mL increments of 0.00100 M KSCN are added to 4.00 mL of 0.200 M Fe(NO[subscript 3])[subscript 3], and for the equilibrium solutions, 0.50 mL increments of…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Kwang-Soon; Lee, Chang Heon; Ahn, Hong-Joo
2013-07-01
Based on the regulation of the activity concentration of Cs-137, Co-58, Co-60, Fe-55, Ni-59, Ni-63, Sr-90, Nb-94, and Tc-99, and the total alpha from the radioactive waste acceptance criteria, the measurement of the activity concentration of these nuclides in low and intermediate levels of radioactive waste such as in paper, cotton, vinyl and plastic samples was investigated. A dry ashing method was applied to obtain a concentration effect of the samples. Owing to the temperature dependence of the volatility for cesium, the temperature of 300 to 650 deg. C was examined. It was found that 450 deg. C is themore » optimum dry ashing temperature. After dry ashing, the produced ash was dissolved with HNO{sub 3}, HCl, and HF by a high-performance microwave digestion system. The ash sample, for the most part, was completely dissolved with 10 mL of HNO{sub 3}, 4 mL of HCl, and 0.25 mL of HF by a high-performance microwave digestion system using a nova high temperature rotor at 250 deg. C for 90 min until reaching 0.2 g. To confirm the reliability of cesium loss after the performance of the dry ashing procedure, a cesium standard solution for AAS and a Cs-137 standard solution for gamma spectrometry were added to a paper towel or a planchet of stainless steel, respectively. Cesium was measured by AAS, ICP-MS, and gamma spectrometry. The volatility of cesium did not occur until 450 deg. C ashing. (authors)« less
Moein, Mohammad Mahdi; Javanbakht, Mehran; Karimi, Mohammad; Akbari-Adergani, Behrouz
2015-03-01
Sol-gel based molecularly imprinted polymer (MIP) nanofiber was successfully fabricated by electrospinning technique on the surface of a stainless steel bar. The manufactured tool was applied for on-line selective solid phase microextraction (SPME) and determination of acesulfame (ACF) as an artificial sweetener with high performance liquid chromatography (HPLC). The selective ability of method for the extraction of ACF was investigated in the presence of some selected sweeteners such as saccharine (SCH), aspartame (ASP) and caffeine (CAF). Electrospinning of MIP sol-gel solution on the stainless steel bar provided an unbreakable sorbent with high thermal, mechanical, and chemical stability. Moreover, application of the MIP-SPME tool revealed a unique approach for the selective microextraction of the analyte in beverage samples. In this work, 3-(triethoxysilyl)-propylamine (TMSPA) was chosen as a precursor due to its ability to imprint the analyte by hydrogen bonding, Van der Walls, and dipole-dipole interactions. Nylon 6 was also added as a backbone and support for the precursor in which sol could greatly growth during the sol-gel process and makes the solution electrospinable. Various effective parameters in the extraction efficiency of the MIP-SPME tool such as loading time, flow rate, desorption time, selectivity, and the sample volume were evaluated. The linearity for the ACF in beverage sample was in the range of 0.78-100.5 ng mL(-1). Limit of detection (LOD) and quantification (LOQ) were 0.23 and 0.78 ng mL(-1) respectively. The RSD values (n=5) were all below 3.5%at the 20 ng mL(-1) level. Copyright © 2014 Elsevier B.V. All rights reserved.
Rezazadeh, Maryam; Yamini, Yadollah; Seidi, Shahram; Tahmasebi, Elham; Rezaei, Fatemeh
2014-04-09
Electromembrane surrounded solid phase microextraction (EM-SPME) of acidic herbicides was studied for the first time. In order to investigate the capability of this new microextraction technique to analyze acidic targets, chlorophenoxy acid (CPA) herbicides were quantified in plant tissue. 1-Octanol, was sustained in the pores of the wall of a hollow fiber and served as supported liquid membrane (SLM). Other EM-SPME related parameters, including extraction time, applied voltage, and pHs of the sample solution and the acceptor phase, were optimized using experimental design. A 20 min time frame was needed to reach the highest extraction efficiency of the analytes from a 24 mL alkaline sample solution across the organic liquid membrane and into the aqueous acceptor phase through a 50 V electrical field, and to their final adsorption on a carbonaceous anode. In addition to high sample cleanup, which made the proposed method appropriate for analysis of acidic compounds in a complicated media (plant tissue), 4.8% of 2-methyl-4-chlorophenoxyacetic acid (MCPA) and 0.6% of 2,4-dichlorophenoxyacetic acid (2,4-D) were adsorbed on the anode, resulting in suitable detection limits (less than 5 ng mL -1 ), and admissible repeatability and reproducibility (intra- and interassay precision were in the ranges of 5.2-8.5% and 8.8-12.0%, respectively). Linearity of the method was scrutinized within the ranges of 1.0-500.0 and 10.0-500.0 ng mL -1 for MCPA and 2,4-D, respectively, and coefficients of determination greater than 0.9958 were obtained. Optimal conditions of EM-SPME of the herbicides were employed for analysis of CPAs in whole wheat tissue.
A Simplified Extemporaneously Prepared Potassium Chloride Oral Solution.
Tannous, Elias; Tal, Yana; Amarny, Kamal
2016-01-01
Although commercial preparations of oral potassium supplements are usually available, there are times when our Medical Center is faced with situations in which the oral solution of potassium chloride is not available. This solution is necessary for our pediatric outpatients who cannot swallow tablets and need an oral solution. Moreover, there are no studies available which describe an extemporaneously prepared potassium chloride oral solution on which we can rely for assigning a beyond-use date. The aim of this study was to formulate an extemporaneous pediatric oral solution of potassium chloride and to determine the physical and chemical stability of this preparation. We prepared 1 mMoL/mL by withdrawing 25 mL of potassium chloride 14.9%. Ora-Sweet SF was added to 50 mL in a metered flask. The solution was kept refrigerated (2°C to 8°C). Samples were withdrawn to measure potassium concentration, pH, and microbial overgrowth. The test was performed by our biochemical laboratory. The oral solution of potassium chloride 1 mMoL/mL stored at 2°C to 8°C maintained at least 91% of the initial concentration for 28 days. There were no notable changes in pH, and the solution remained physically stable with no visual microbial growth. The oral solution of potassium chloride 1 mMoL/mL prepared in Ora-Sweet and stored at 2°C to 8°C in amber glass bottles is expected to remain stable for 28 days. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
NASA Astrophysics Data System (ADS)
Dhara, Sangita; Misra, N. L.; Aggarwal, S. K.; Venugopal, V.
2010-06-01
An energy dispersive X-ray fluorescence method for determination of cadmium (Cd) in uranium (U) matrix using continuum source of excitation was developed. Calibration and sample solutions of cadmium, with and without uranium were prepared by mixing different volumes of standard solutions of cadmium and uranyl nitrate, both prepared in suprapure nitric acid. The concentration of Cd in calibration solutions and samples was in the range of 6 to 90 µg/mL whereas the concentration of Cd with respect to U ranged from 90 to 700 µg/g of U. From the calibration solutions and samples containing uranium, the major matrix uranium was selectively extracted using 30% tri-n-butyl phosphate in dodecane. Fixed volumes (1.5 mL) of aqueous phases thus obtained were taken directly in specially designed in-house fabricated leak proof Perspex sample cells for the energy dispersive X-ray fluorescence measurements and calibration plots were made by plotting Cd Kα intensity against respective Cd concentration. For the calibration solutions not having uranium, the energy dispersive X-ray fluorescence spectra were measured without any extraction and Cd calibration plots were made accordingly. The results obtained showed a precision of 2% (1 σ) and the results deviated from the expected values by < 4% on average.
2016-03-23
polystyrene tubes . This procedure was repeated 30 times to simulate an annual exposure to acidic precipitation weathering. The average annual number...with diluted nitric acid in a 10 mL test tube . This sample was used for the ICP-AES analysis. The remainder of the sample solution was acid...Water at a Semiconducter Electrode. Nature 238 9. Gamer AO, Leibold E, van Ravenzwaay B. 2006. The in vitro absorption of microfine zinc oxide and
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cherian, Angel Susan; Kartha, C. Sudha; Vijayakumar, K. P.
2014-01-28
Consequence of variation in Indium concentration in chlorine doped In2S{sub 3} thin films deposited by spray pyrolysis technique was studied. Chlorine was incorporated in the spray solution, using HCl and Indium concentration was varied by adjusting In/S ratio Interestingly, the photo response of all chlorine doped samples augmented compared to pristine samples; but the highest photosensitivity value of ∼2300 was obtained only when 36ml 0.5M HCl was added to the solution of In{sub 2}S{sub 3} having In/S=2/8. It was also observed that samples with high photosensitivity possess higher band gap and variation in sub band gap absoption levels were observedmore » with increase in Indium concentration. The present study proved that concentration of Indium plays an important role in controlling the crystallinity and photosensitivity of chlorine doped samples.« less
Effect of iron II on hydroxyapatite dissolution and precipitation in vitro.
Delbem, A C B; Alves, K M R P; Sassaki, K T; Moraes, J C S
2012-01-01
The aim of this study was to evaluate the effect of iron II on the dissolution and precipitation of synthetic hydroxyapatite (HA). HA powder was suspended in solutions of iron (0.84 µg/ml, Fe0.84; 18.0 µg/ml, Fe18; 70.0 µg/ml, Fe70), fluoride (1,100 µg/ml, F1,100), and deionized water and submitted to pH cycling. After pH cycling, the samples were analyzed by infrared spectroscopy and X-ray diffraction. The concentrations of fluoride, calcium, phosphorus, and iron were also analyzed. The data were submitted to ANOVA, and analyzed by Tukey's test (p < 0.05). The infrared spectrum showed a reduction in all bands corresponding to phosphates and hydroxyls and an increase in the carbonate band in the groups with iron. The intensity of the phosphate bands increased and that of the hydroxyl bands decreased in the group F1,100. It was observed that there was a higher concentration of Ca in the group F1,100, with no significant difference between the groups Fe18 and Fe70 (p > 0.05). There was an increase in Fe concentration in the HA directly related to the Fe concentration of the treatment solutions. Results show that the presence of Fe causes the precipitation of apatite with high solubility. Copyright © 2012 S. Karger AG, Basel.
Wang, Weina; Ma, Ruiyang; Wu, Qiuhua; Wang, Chun; Wang, Zhi
2013-05-15
In this study, a magnetic microsphere-confined graphene (Fe3O4@SiO2-G) was prepared as a novel adsorbent for the preconcentration of some phthalate esters in environmental water and soybean milk samples prior to high performance liquid chromatography analysis. The properties and morphology of the Fe3O4@SiO2-G were characterized by transmission electron microscopy and X-ray diffraction. This novel graphene-based magnetic nanocomposite showed great adsorptive ability toward the analytes. The method, which takes the advantages of both the high adsorption capacity of G and easy phase separation of the magnetic adsorbent from the sample solution, could avoid the time-consuming experimental procedures related to the traditional solid phase extraction. Various experimental parameters that could affect the extraction efficiencies, such as the amount of Fe3O4@SiO2-G, the extraction time, the pH of sample solution and the desorption conditions, were investigated. Under the optimum conditions, the limits of detection (S/N=3) of the method for the compounds were between 0.07 and 0.10 ng mL(-1) in water samples, and between 0.15 and 0.30 ng mL(-1) in soybean milk samples. The relative standard deviations (RSDs) varied from 2.7% to 6.1% (n=5). The recoveries of the method were in the range between 87.2% and 109.0% for environmental water and soybean milk samples. The method is suitable to determine the five phthalate esters (diallyl phthalate, di-n-propyl-phthalate, benzyl butyl phthalate, dicyclohexyl-phthalate and diethyl-hexyl-phthalate) in environmental water and soybean milk samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Schumacher, J; Schumacher, J; de Graves, F; Steiger, R; Schramme, M; Smith, R; Coker, M
2001-05-01
The response of horses, with solar pain in the dorsal or palmar aspect of the foot, to 6 or 10 ml local analgesic solution administered into the distal interphalangeal (DIP) joint was examined. Lameness was induced in 7 horses by creating solar pain in the dorsal aspect of one forefoot and, at another time, the palmar aspect of the other forefoot with set-screws inserted into a custom-made shoe. Horses were videotaped trotting before and after application of set-screws and, in separate trials, after 6 or 10 ml local analgesic solution was administered into the DIP joint. Lameness scores were assigned by examining videotaped gaits. Scores were significantly lower (P < 0.05) for horses with set-screws applied to the angles of the sole and receiving 10 ml, but not 6 ml, local analgesic solution into the DIP joint. Scores were significantly lower (P < 0.05) for all horses with set-screws in the dorsal margin of the sole receiving either volume of local analgesic solution. Analgesia of the DIP joint was less effective in desensitising the angles of the sole than in desensitising the dorsal margin of the sole, and 10 ml local analgesic solution was more effective than 6 ml in desensitising these regions. The response of horses with solar pain to local analgesic solution in the DIP joint was influenced by the volume administered and the region of sole affected.
Sun, Mei; Wu, Qianghua
2010-04-15
A cloud point extraction (CPE) method for the preconcentration of ultra-trace aluminum in human albumin prior to its determination by graphite furnace atomic absorption spectrometry (GFAAS) had been developed in this paper. The CPE method was based on the complex of Al(III) with 1-(2-pyridylazo)-2-naphthol (PAN) and Triton X-114 was used as non-ionic surfactant. The main factors affecting cloud point extraction efficiency, such as pH of solution, concentration and kind of complexing agent, concentration of non-ionic surfactant, equilibration temperature and time, were investigated in detail. An enrichment factor of 34.8 was obtained for the preconcentration of Al(III) with 10 mL solution. Under the optimal conditions, the detection limit of Al(III) was 0.06 ng mL(-1). The relative standard deviation (n=7) of sample was 3.6%, values of recovery of aluminum were changed from 92.3% to 94.7% for three samples. This method is simple, accurate, sensitive and can be applied to the determination of ultra-trace aluminum in human albumin. 2009 Elsevier B.V. All rights reserved.
Application of porous materials in oil substances separation from water
NASA Astrophysics Data System (ADS)
Gołub, Adam; Piekutin, Janina
2017-11-01
The aim of the study was to determine the ability of the four porous materials: birch bark, cork, glass wool, and polyurethane foam to reduce the mineral oil index and the concentration of n-alkanes C7H16-C38H78 as well as to select the most efficient materials. Model solutions of gasoline, diesel oil, and distilled water with the following values of mineral oil index were prepared to tests: 52 μg/dm3, 68 μg/dm3 and 73 μg/dm3. Then, studies were carried out using a dynamic method, wherein the columns were filled with adsorbents tested, and in each of three testing series, 500 mL of the model solution at constant bed load of 1,0551 m3/m2h was filtered through the column. After filtration, the collected sample had volume of 250 mL. The collected samples were subject to determination of mineral oil index and concentrations of n-alkanes from C7H16 to C38H78. Studies have shown that the most effective materials to lower the mineral oil index and the concentrations of n-alkanes in water are birch bark and glass wool.
Kissinger, L D; Robins, R H
1985-03-15
A silver-modified, normal-phase, high-performance liquid chromatographic system has been developed for prostaglanding bulk drugs and triacetin solutions. Silver nitrate present in the mobile phase results in high selectivity for cis/trans isomers with conventional silica columns. Prostaglandins were esterified with alpha-bromo-2'-acetonaphthone prior to chromatography to provide high detectability at 254 nm. For dilute triacetin solutions, a sample preparation scheme based on gravity-flow chromatography with silica columns was developed to isolate the prostaglandin from triacetin prior to derivatization. The analytical technique was applied to triacetin solutions containing as little as 10 micrograms/ml arbaprostil [15-(R)-methyl-PGE2].
Tatsumi, Yoshiyuki; Yokoo, Mamoru; Arika, Tadashi; Yamaguchi, Hideyo
2001-01-01
The in vitro activity of KP-103, a novel triazole derivative, against pathogenic fungi that cause dermatomycoses and its therapeutic efficacy against plantar tinea pedis and cutaneous candidiasis in guinea pigs were investigated. MICs were determined by a broth microdilution method with morpholinepropanesulfonic acid-buffered RPMI 1640 medium for Candida species and with Sabouraud dextrose broth for dermatophytes and by an agar dilution method with medium C for Malassezia furfur. KP-103 was the most active of all the drugs tested against Candida albicans (geometric mean [GM] MIC, 0.002 μg/ml), other Candida species including Candida parapsilosis and Candida glabrata (GM MICs, 0.0039 to 0.0442 μg/ml), and M. furfur (GM MIC, 0.025 μg/ml). KP-103 (1% solution) was highly effective as a treatment for guinea pigs with cutaneous candidiasis and achieved mycological eradication in 8 of the 10 infected animals, whereas none of the imidazoles tested (1% solutions) was effective in even reducing the levels of the infecting fungi. KP-103 was as active as clotrimazole and neticonazole but was less active than lanoconazole and butenafine against Trichophyton rubrum (MIC at which 80% of isolates are inhibited [MIC80], 0.125 μg/ml) and Trichophyton mentagrophytes (MIC80, 0.25 μg/ml). However, KP-103 (1% solution) exerted therapeutic efficacy superior to that of neticonazole and comparable to those of lanoconazole and butenafine, yielding negative cultures for all samples from guinea pigs with plantar tinea pedis tested. This suggests that KP-103 has better pharmacokinetic properties in skin tissue than the reference drugs. Because the in vitro activity of KP-103, unlike those of the reference drugs, against T. mentagrophytes was not affected by hair as a keratinic substance, its excellent therapeutic efficacy seems to be attributable to good retention of its antifungal activity in skin tissue, in addition to its potency. PMID:11302816
Mahmoud, B S M
2014-01-01
This study evaluated the efficacy of grape seed extract (GE), citric acid (CA) and lactic acid (LA) on the inactivation of Vibrio vulnificus and inherent microflora in fresh shucked oysters. The minimum inhibitory concentration (MIC) of GE, CA or LA against V. vulnificus was determined. Furthermore, the shucked oysters were artificially inoculated with V. vulnificus. The inoculated shucked oysters (25 g) were then dipped in 250 ml GE, CA or LA solutions for 10 min. The population of V. vulnificus in shucked oysters was determined. The effects of the treatments with GE, CA or LA solutions on the inherent microbiota in fresh shucked oysters during storage at 5°C for 20 days were also studied. The MICs of GE, CA or LA against V. vulnificus were 10.0, 5.0 or 1.0 mg ml(-1), respectively. The concentrations of 500, 300 or 150 mg ml(-1) GE, CA or LA solutions were needed to reduce the population of V. vulnificus to below the detection level (1.0 log g(-1)). Treatment with 500, 300, 150 mg ml(-1) GE, CA or LA significantly reduced the initial inherent microbiota in fresh shucked oysters, and inherent levels were significantly (P < 0.05) lower than the control sample throughout refrigerated storage for 20 days. Oysters filter large volume of seawater during their feeding activities that concentrate bacteria such as Vibrio vulnificus in their body. The presence of V. vulnificus in oysters has a serious impact on public health and international trade. There is increasing concern over the use of chemical preservatives. Furthermore, the food industry is looking for new natural preservation methods. This study indicated that lactic acid and citric acid wash solutions could offer an inexpensive, natural and strong approach to control V. vulnificus and spoilage bacteria in fresh shucked for the oyster industry. © 2013 The Society for Applied Microbiology.
May, I.; Rowe, J.J.
1965-01-01
A modified Morey bomb was designed which contains a removable nichromecased 3.5-ml platinium crucible. This bomb is particularly useful for decompositions of refractory samples for micro- and semimicro-analysis. Temperatures of 400-450?? and pressures estimated as great as 6000 p.s.i. were maintained in the bomb for periods as long as 24 h. Complete decompositions of rocks, garnet, beryl, chrysoberyl, phenacite, sapphirine, and kyanite were obtained with hydrofluoric acid or a mixture of hydrofluoric and sulfuric acids; the decomposition of chrome refractory was made with hydrochloric acid. Aluminum-rich samples formed difficultly soluble aluminum fluoride precipitates. Because no volatilization losses occur, silica can be determined on sample solutions by a molybdenum-blue procedure using aluminum(III) to complex interfering fluoride. ?? 1965.
Effects of intravenous delivery systems on infused red blood cells.
Gibson, J S; Leff, R D; Roberts, R J
1984-03-01
The effects of various intravenous delivery systems on the integrity of infused red blood cells (RBCs) were studied. Using a factorial design, whole blood and packed RBCs were infused through i.v. delivery systems employing various combinations of i.v. tubing diameter and length, needle gauge, infusion rate (5 and 50 ml/hr), type of infusion pump (piston, diaphragm, or peristaltic operation), and type of blood product. The age and temperature of the blood filter used were held constant. A 5-ml sample of the blood product obtained during each experimental run was analyzed for plasma free-hemoglobin to assess the degree of hemolysis. Osmotic fragility of the RBCs was evaluated by measuring the percentage of hemolysis in the blood products in various concentrations of sodium chloride solution. Type of blood product and i.v. pump were the only variables significantly influencing RBC hemolysis. In both blood products, a greater degree of hemolysis occurred with the peristaltic-type pump than with the other types of pumps. In packed RBCs, the diaphragm-type pump produced greater hemolysis than the piston-type pump, but hemolysis was similar in whole-blood samples. Regardless of the type of pump, more hemolysis occurred in whole blood at the 5-ml/hr infusion rate than at the 50-ml/hr rate, but the converse was true in packed RBCs. Samples of both blood products were less osmotically fragile than their respective controls at sodium chloride concentrations ranging from 0.30 to 0.50%.(ABSTRACT TRUNCATED AT 250 WORDS)
Ochiai, Nobuo; Tsunokawa, Jun; Sasamoto, Kikuo; Hoffmann, Andreas
2014-12-05
A novel multi-volatile method (MVM) using sequential dynamic headspace (DHS) sampling for analysis of aroma compounds in aqueous sample was developed. The MVM consists of three different DHS method parameters sets including choice of the replaceable adsorbent trap. The first DHS sampling at 25 °C using a carbon-based adsorbent trap targets very volatile solutes with high vapor pressure (>20 kPa). The second DHS sampling at 25 °C using the same type of carbon-based adsorbent trap targets volatile solutes with moderate vapor pressure (1-20 kPa). The third DHS sampling using a Tenax TA trap at 80 °C targets solutes with low vapor pressure (<1 kPa) and/or hydrophilic characteristics. After the 3 sequential DHS samplings using the same HS vial, the three traps are sequentially desorbed with thermal desorption in reverse order of the DHS sampling and the desorbed compounds are trapped and concentrated in a programmed temperature vaporizing (PTV) inlet and subsequently analyzed in a single GC-MS run. Recoveries of the 21 test aroma compounds for each DHS sampling and the combined MVM procedure were evaluated as a function of vapor pressure in the range of 0.000088-120 kPa. The MVM provided very good recoveries in the range of 91-111%. The method showed good linearity (r2>0.9910) and high sensitivity (limit of detection: 1.0-7.5 ng mL(-1)) even with MS scan mode. The feasibility and benefit of the method was demonstrated with analysis of a wide variety of aroma compounds in brewed coffee. Ten potent aroma compounds from top-note to base-note (acetaldehyde, 2,3-butanedione, 4-ethyl guaiacol, furaneol, guaiacol, 3-methyl butanal, 2,3-pentanedione, 2,3,5-trimethyl pyrazine, vanillin, and 4-vinyl guaiacol) could be identified together with an additional 72 aroma compounds. Thirty compounds including 9 potent aroma compounds were quantified in the range of 74-4300 ng mL(-1) (RSD<10%, n=5). Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
Batista, Bruno Lemos; Rodrigues, Jairo Lisboa; Souza, Vanessa Cristina de Oliveira; Barbosa, Fernando
2009-11-20
An ultrasound-assisted extraction method is proposed for the determination of trace elements in hair samples by inductively coupled plasma-mass spectrometry (ICP-MS) for forensic investigation. Prior to analysis, 25mg of hair samples were accurately weighed into (15 mL) conical tubes. Then, 2 mL of 20% HNO(3) is added to the samples, sonicated at 2 min (50W, 100% amplitude), and then further diluted to 10 mL with Milli-Q water. Resulted diluted slurries are centrifuged and the analytes are directly determined in the supernatant. Calibrations against aqueous solutions were carried out with rhodium as internal standard. The method was successfully applied for the extraction of Al, As, Ba, Be, Cd, Co, Cr, Cu, Mn, Pb, Tl, U, V and Zn with a method detection limit (3s, n=20) of 0.1, 0.4, 0.2, 0.09, 0.08, 0.04, 0.1, 2.9, 1.0, 0.9, 0.04, 0.05, 0.1 and 4.2 ng/g, respectively. Method accuracy is traceable to Certified Reference Materials (CRMs) 85 and 86 human hair from the International Atomic Energy Agency (IAEA). Additional validation data are provided based on the analysis of hair samples from the trace elements intercomparison program operated by the Institut National de Sante' Publique du Quebec, Canada. The proposed method is very simple and can be applied for forensic purposes with the elimination of sample digestion step prior to analysis. Then, a considerable improvement in the sample throughput is archived with the use of the proposed method.
See, Kay Choong; Lee, Margaret; Mukhopadhyay, Amartya
2009-01-01
Regional citrate anti-coagulation for continuous renal replacement therapy chelates calcium to produce the anti- coagulation effect. We hypothesise that a calcium-free replacement solution will require less citrate and produce fewer metabolic side effects. Fifty patients, in a Medical Intensive Care Unit of a tertiary teaching hospital (25 in each group), received continuous venovenous hemofiltration using either calcium-containing or calcium-free replacement solutions. Both groups had no significant differences in filter life, metabolic alkalosis, hypernatremia, hypocalcemia, and hypercalcemia. However, patients using calcium-containing solution developed metabolic alkalosis earlier, compared to patients using calcium-free solution (mean 24.6 hours,CI 0.8-48.4 vs. 37.2 hours, CI 9.4-65, P = 0.020). When calcium-containing replacement solution was used, more citrate was required (mean 280 ml/h, CI 227.2-332.8 vs. 265 ml/h, CI 203.4-326.6, P = 0.069), but less calcium was infused (mean 21.2 ml/h, CI 1.2-21.2 vs 51.6 ml/h, CI 26.8-76.4, P < or = 0.0001).
Fully Integrated Microfluidic Device for Direct Sample-to-Answer Genetic Analysis
NASA Astrophysics Data System (ADS)
Liu, Robin H.; Grodzinski, Piotr
Integration of microfluidics technology with DNA microarrays enables building complete sample-to-answer systems that are useful in many applications such as clinic diagnostics. In this chapter, a fully integrated microfluidic device [1] that consists of microfluidic mixers, valves, pumps, channels, chambers, heaters, and a DNA microarray sensor to perform DNA analysis of complex biological sample solutions is present. This device can perform on-chip sample preparation (including magnetic bead-based cell capture, cell preconcentration and purification, and cell lysis) of complex biological sample solutions (such as whole blood), polymerase chain reaction, DNA hybridization, and electrochemical detection. A few novel microfluidic techniques were developed and employed. A micromix-ing technique based on a cavitation microstreaming principle was implemented to enhance target cell capture from whole blood samples using immunomagnetic beads. This technique was also employed to accelerate DNA hybridization reaction. Thermally actuated paraffin-based microvalves were developed to regulate flows. Electrochemical pumps and thermopneumatic pumps were integrated on the chip to provide pumping of liquid solutions. The device is completely self-contained: no external pressure sources, fluid storage, mechanical pumps, or valves are necessary for fluid manipulation, thus eliminating possible sample contamination and simplifying device operation. Pathogenic bacteria detection from ~mL whole blood samples and single-nucleotide polymorphism analysis directly from diluted blood were demonstrated. The device provides a cost-effective solution to direct sample-to-answer genetic analysis, and thus has a potential impact in the fields of point-of-care genetic analysis, environmental testing, and biological warfare agent detection.
Brennan, K A; Eapen, G; Turnbull, D
2010-04-01
In 2008, the National Patient Safety Agency (NPSA) published a report after 42 incidents and two deaths where glucose-containing flush solutions were attached to the arterial line. The molar concentration of 5% glucose is 277 mmol litre(-1). Only a tiny amount of sample contamination will lead to an artificially high glucose. As the NPSA sought a solution, a bench model was constructed to compare the performance of three open and three closed arterial line systems in limiting sample contamination. All arterial line systems were set up in a standard manner and pressurized to 300 mm Hg with 5% glucose used as the flush solution. This was connected to the 'radial artery' using an 18 G needle representing the radial cannula. The radial artery was simulated using a wide-bore extension set with 'blood' flow at 60 ml min(-1). Blood was simulated by the addition of red dye to Hartmann's solution. Increasing multiples of arterial line dead space were aspirated and discarded. Blood samples were then obtained and glucose concentration was measured. Significant glucose contamination (3 mmol litre(-1) +/-3.4) was detected in all open arterial line systems up to an aspiration volume of five times the dead space. No samples from the closed systems recorded glucose concentration >1 mmol litre(-1). Recommended minimal discard volumes are inadequate in the presence of glucose as the flush solution and can lead to high blood glucose readings, inappropriate insulin use, and iatrogenic neuroglycopaenia. Our study demonstrates that the closed-loop arterial sampling system could be the universal solution sought by the NPSA.
Golshekan, Mostafa; Shariati, Shahab
2013-01-01
In this study, magnetite nanoparticles with particle size lower than 47 nm were synthesized and were applied for preconcentration of Pb2+ ions from aqueous solutions. To preconcentrate the Pb2+ ions, the surface of the synthesized nano particles was modified with sodium dodecyl sulfate (SDS) as an anionic surfactant. A new chelating agent (2-((E)-2-amino-4,5-dinitrophenylimino)methyl)phenol) was synthesized and used to form a very stable complex with Pb2+ ions. The lead ions formed complexes and were quantitatively extracted with SDS-coated magnetite nanoparticles. After magnetic separation of adsorbent, the adsorbent was eluted with 0.5% (v/v) HC1 in dimethyl sulfoxide (DMSO) prior to analysis by flame atomic absorption spectrometry (FAAS). Orthogonal array design (OAD) was used to study and optimize the different experimental parameters. Under the optimum conditions, enhancement factor up to 63.5 was achieved for extraction from only 10 mL of sample solution and the relative standard deviation (RSD %) of the method was lower than 2.8%. The obtained calibration curve was linear in the range of 1-300 pg L-' with reasonable linearity (r2 > 0.998). The limit of detection (LOD) based on S/N = 3 was 0.04 microg L(-1) for 10 mL sample volumes. Finally, applicability of the proposed method was successfully confirmed by preconcentration and determination of trace amounts of lead ions in environmental samples and satisfactory results were obtained.
Prieto, Ailette; Rodil, Rosario; Quintana, José Benito; Cela, Rafael; Möder, Monika; Rodríguez, Isaac
2014-05-01
In this work, the suitability of bulk polyethersulfone (PES) for sorptive microextraction of eight polar, chlorinated phenoxy acids and dicamba from environmental water samples is assessed and the analytical features of the optimized method are compared to those reported for other microextraction techniques. Under optimized conditions, extractions were performed with samples (18 mL) adjusted at pH 2 and containing a 30% (w/v) of sodium chloride, using a tubular PES sorbent (1 cm length × 0.7 mm o.d., sorbent volume 8 µL). Equilibrium conditions were achieved after 3h of direct sampling, with absolute extraction efficiencies ranging from 39 to 66%, depending on the compound. Analytes were recovered soaking the polymer with 0.1 mL of ethyl acetate, derivatized and determined by gas chromatography-mass spectrometry (GC-MS). Achieved quantification limits (LOQs) varied between 0.005 and 0.073 ng mL(-1). After normalization with the internal surrogate (IS), the efficiency of the extraction was only moderately affected by the particular characteristics of different water samples (surface and sewage water); thus, pseudo-external calibration, using spiked ultrapure water solutions, can be used as quantification technique. The reduced cost of the PES polymer allowed considering it as a disposable sorbent, avoiding variations in the performance of the extraction due to cross-contamination problems and/or surface modification with usage. Copyright © 2014 Elsevier B.V. All rights reserved.
Determination of total selenium in food samples by d-CPE and HG-AFS.
Wang, Mei; Zhong, Yizhou; Qin, Jinpeng; Zhang, Zehua; Li, Shan; Yang, Bingyi
2017-07-15
A dual-cloud point extraction (d-CPE) procedure was developed for the simultaneous preconcentration and determination of trace level Se in food samples by hydride generation-atomic fluorescence spectrometry (HG-AFS). The Se(IV) was complexed with ammonium pyrrolidinedithiocarbamate (APDC) in a Triton X-114 surfactant-rich phase, which was then treated with a mixture of 16% (v/v) HCl and 20% (v/v) H 2 O 2 . This converted the Se(IV)-APDC into free Se(IV), which was back extracted into an aqueous phase at the second cloud point extraction stage. This aqueous phase was analyzed directly by HG-AFS. Optimization of the experimental conditions gave a limit of detection of 0.023μgL -1 with an enhancement factor of 11.8 when 50mL of sample solution was preconcentrated to 3mL. The relative standard deviation was 4.04% (c=6.0μgL -1 , n=10). The proposed method was applied to determine the Se contents in twelve food samples with satisfactory recoveries of 95.6-105.2%. Copyright © 2016 Elsevier Ltd. All rights reserved.
Effect of a polyethylene-lined administration set on the availability of diazepam injection.
Hancock, B G; Black, C D
1985-02-01
Delivery of diazepam through a polyethylene-lined i.v. administration set and through a polyvinyl chloride (PVC) set was compared. Diazepam was prepared in concentrations of 50 mg/500 mL and 100 mg/500 mL in 0.9% sodium chloride injection and 5% dextrose injection in glass containers. Diazepam concentrations were measured by high-performance liquid chromatography at 0 through 5 hours in samples collected simultaneously from the glass solution containers and from the distal ends of a PVC administration set and a polyethylene-lined (non-PVC) set. Flow rates of 50 and 100 mL/hr were tested. For the non-PVC sets, diazepam concentration in the infusate was not significantly different from concentration in the glass container at any sampling time. The overall percentage of diazepam recovered was 100.7 +/- 6.8%. For the PVC sets, diazepam concentration in the infusate was less than in the container at all sampling times, and the overall percentage of diazepam recovered was 65.4 +/- 13.3% (significantly different from delivery for the non-PVC sets). Delivery through the non-PVC sets was not affected by flow rate, type of solution, or concentration of diazepam. For infusion periods of up to five hours, delivery of diazepam through polyethylene-lined i.v. administration sets was superior to delivery through polyvinyl chloride sets.
Djeno, Ivana Tudorić; Duzel, Viktor; Ajduk, Marko; Oremus, Zrinka Safarić; Zupcić, Miroslav; Dusper, Silva; Jukić, Dubravko; Husedzinović, Ino
2012-06-01
The clinical presentation of a subarachnoid block (SAB) is dependent upon the intrathecal spread of local anesthetic (LA). Intrathecal distribution depends on the chemical and physical characteristics of LA, puncture site, technique used, patient anatomical characteristics and hydrodynamic properties of cerebrospinal fluid. We tried to determine whether a combined glucose/LA solution can render a clinically significant difference in sensory block distribution and motor block intensity.This was a controlled, randomized and double blinded study. The surgical procedures were stripping of the great or small saphenous vein and extirpation of remaining varicose veins. The study included 110 patients distributed into two groups: Hyperbaric (7.5 mg levobupivacaine (1.5 ml 0.5% Chirocaine) + 50 microg Fentanyl (0.5 ml Fentanil) and 1 ml 10% glucose (Pliva)) vs. Hypobaric (7.5 mg levobupivacaine (1.5 ml 0.5% Chirocaine) + 50 microg Fentanyl (0.5 ml Fentanil) and 1 ml 0.9% NaCl (Pliva, Zagreb)) adding to a total volume of 3.5 ml per solution. Spinal puncture was at L3-L4 level. Spinal block distribution was assessed in five minute intervals and intensity of motor block was assessed according to the modified Bromage scale. Pain was assessed with the Visual Analogue Scale. A statistically significant difference in sensory block distribution, motor block intensity and recovery time was established between hyperbaric and hypobaric solutions. By increasing the specific density of anesthetic solution, a higher sensory block, with lesser variability, a diminished influence of Body Mass Index, decreased motor block intensity and faster recovery time may be achieved.
Ikarashi, Yoshiaki; Miyazawa, Norimasa; Shimamura, Kimio; Sato, Nobuo; Yoshizawa, Ken-ichi; Hayashi, Masahito; Takano, Katsuhiro; Miyamoto, Michiko; Kojima, Takashi; Sakaguchi, Hiroshi; Fujiio, Makiko
2009-01-01
A simple determination method for preservative chlorphenesin in cosmetics was developed. Cosmetic samples were dissolved in methanol. The sample solution was analyzed by high-performance liquid chromatography (HPLC) with ODS column, using water-methanol (55:45) or water-acetonitrile (3:1) adjusted to pH 2.5 with phosphoric acid as the mobile phase. Chlorphenesin was detected with ultraviolet light detection at 280 nm. A linear relation was obtained between the peak areas and the concentrations of chlorphenesin in the range of 1-500 microg/ml. The determination limit of chlorphenesin was 1-2 microg/ml. Recoveries of chlorphenesin spiked in lotion and milky lotion at the levels of 0.03% and 0.3% were 98.8-100.0%. This method was applied for cosmetics including 0.03% and 0.3% of chlorphenesin and their content corresponded with the determined values.
Impurities Removal in Seawater to Optimize the Magnesium Extraction
NASA Astrophysics Data System (ADS)
Natasha, N. C.; Firdiyono, F.; Sulistiyono, E.
2017-02-01
Magnesium extraction from seawater is promising way because magnesium is the second abundant element in seawater and Indonesia has the second longest coastline in the world. To optimize the magnesium extraction, the impurities in seawater need to be eliminated. Evaporation and dissolving process were used in this research to remove the impurities especially calcium in seawater. Seawater which has been evaporated from 100 ml to 50 ml was dissolved with variations solution such as oxalic acid and ammonium bicarbonate. The solution concentration is 100 g/l and it variations are 2 ml, 4 ml, 6 ml, 8 ml, 10 ml, 20 ml, 30 ml, 40 ml and 50 ml. This step will produce precipitate and filtrate then it will be analysed to find out the result of this process. The precipitate was analysed by X-ray Diffraction (XRD) and Scanning Electron Microscope (SEM) but the filtrate was analysed by Inductively Coupled Plasma (ICP). XRD analysis shows that calcium oxalate and calcium carbonate were formed and ICP analysis shows that the remaining calcium in seawater using oxalic acid is about 0.01% and sodium 0.14% but when using ammonium bicarbonate the remaining calcium is 2.5% and sodium still more than 90%. The results show that both oxalic acid and ammonium bicarbonate can remove the impurities but when using oxalic acid, not only the impurities but also magnesium was precipitated. The conclusion of this research is the best solution to remove the impurities in seawater without precipitate the magnesium is using ammonium bicarbonate.
Delta 14CO2 Record from Vermunt, Austria, February 1959 - June 1983
Levin, Ingeborg [Institut fur Umweltphysik, University of Heidelberg, Germany; Kromer, Bernd [Institut fur Umweltphysik, University of Heidelberg, Germany; Schoch-Fischer, H. [Institut fur Umweltphysik, University of Heidelberg, Germany; Bruns, M. [Institut fur Umweltphysik, University of Heidelberg, Germany; Munnich, M. [Institut fur Umweltphysik, University of Heidelberg, Germany; Berdau, D. [Institut fur Umweltphysik, University of Heidelberg, Germany; Vogel, J. C. [Institut fur Umweltphysik, University of Heidelberg, Germany; Munnich, K. O. [Institut fur Umweltphysik, University of Heidelberg, Germany
1994-01-01
The sampling at Vermunt was discontinued in 1983. During sampling from 1959 to 1983, the sampling methods were modified twice (Levin et al. 1985). From 1959 through November 1965, three dishes with 1.5 L of 0.5 normal sodium hydroxide (NaOH) carbonate-free solution were exposed to the atmosphere for ~3 days, and the atmospheric CO2 absorbed during that time was recovered by acid evolution. From November 1965 through May 1975, samples were collected by pumping fresh air continuously for 10 days through a box containing 1.5 L of a 0.5 normal NaOH solution. The method has been described by Münnich and Vogel (1959). From May 1975 to the time sampling stopped, a technique described by Levin et al. (1980) was used. Air was pumped through a rotating glass tube filled with a packed bed of Raschig rings (hard glass) to enlarge the surface of the absorbing NaOH solution (200 ml of 4 normal NaOH). The CO2 absorption was quantitative and samples represent mean values of 10 days to 2 weeks. In the laboratory, the samples were extracted from the NaOH solution in a vacuum system by adding hydrochloric or sulfuric acid. The CO2 gas samples were purified over charcoal and counted in a proportional counter (Schoch et al. 1980). Delta 14C values are given relative to the NIST oxalic acid activity corrected for decay (Stuiver and Polach 1970).
Study of the interaction of proteins with curcumin and SDS and its analytical application
NASA Astrophysics Data System (ADS)
Wang, Feng; Yang, Jinghe; Wu, Xia; Liu, Shufang
2005-09-01
It is found that protein and sodium dodecyl sulphonate (SDS) can enhance resonance light scattering (RLS) of curcumin (CU). Based on this phenomenon, a new quantitative method for protein in aqueous solution has been developed. In the BR (pH 3.5) buffer, the RLS intensity of CU-SDS system is greatly enhanced by protein. The enhanced RLS is proportional to the concentration of protein in the range of 0.00020-20.0 μg ml -1 for bovine serum albumin (BSA) and 0.00040-1.0 μg ml -1 for human serum albumin (HSA) and their detection limits are 0.16 and 0.041 ng ml -1, respectively. An actual sample is satisfactorily determined. In addition, the interaction mechanism between protein and CU-SDS is also studied by using multi-techniques such as RLS, absorption spectroscopy and fluorescence, zeta potential assay measurement.
Pace, M.N.; Rosentreter, J.J.; Bartholomay, R.C.
2001-01-01
Idaho State University and the US Geological Survey, in cooperation with the US Department of Energy, conducted a study to determine and evaluate strontium distribution coefficients (Kds) of subsurface materials at the Idaho National Engineering and Environmental Laboratory (INEEL). The Kds were determined to aid in assessing the variability of strontium Kds and their effects on chemical transport of strontium-90 in the Snake River Plain aquifer system. Data from batch experiments done to determine strontium Kds of five sediment-infill samples and six standard reference material samples were analyzed by using multiple linear regression analysis and the stepwise variable-selection method in the statistical program, Statistical Product and Service Solutions, to derive an equation of variables that can be used to predict strontium Kds of sediment-infill samples. The sediment-infill samples were from basalt vesicles and fractures from a selected core at the INEEL; strontium Kds ranged from ???201 to 356 ml g-1. The standard material samples consisted of clay minerals and calcite. The statistical analyses of the batch-experiment results showed that the amount of strontium in the initial solution, the amount of manganese oxide in the sample material, and the amount of potassium in the initial solution are the most important variables in predicting strontium Kds of sediment-infill samples.
Taylor Dispersion Analysis as a promising tool for assessment of peptide-peptide interactions.
Høgstedt, Ulrich B; Schwach, Grégoire; van de Weert, Marco; Østergaard, Jesper
2016-10-10
Protein-protein and peptide-peptide (self-)interactions are of key importance in understanding the physiochemical behavior of proteins and peptides in solution. However, due to the small size of peptide molecules, characterization of these interactions is more challenging than for proteins. In this work, we show that protein-protein and peptide-peptide interactions can advantageously be investigated by measurement of the diffusion coefficient using Taylor Dispersion Analysis. Through comparison to Dynamic Light Scattering it was shown that Taylor Dispersion Analysis is well suited for the characterization of protein-protein interactions of solutions of α-lactalbumin and human serum albumin. The peptide-peptide interactions of three selected peptides were then investigated in a concentration range spanning from 0.5mg/ml up to 80mg/ml using Taylor Dispersion Analysis. The peptide-peptide interactions determination indicated that multibody interactions significantly affect the PPIs at concentration levels above 25mg/ml for the two charged peptides. Relative viscosity measurements, performed using the capillary based setup applied for Taylor Dispersion Analysis, showed that the viscosity of the peptide solutions increased with concentration. Our results indicate that a viscosity difference between run buffer and sample in Taylor Dispersion Analysis may result in overestimation of the measured diffusion coefficient. Thus, Taylor Dispersion Analysis provides a practical, but as yet primarily qualitative, approach to assessment of the colloidal stability of both peptide and protein formulations. Copyright © 2016 Elsevier B.V. All rights reserved.
Allahyari, Saeideh; Delazar, Abbas; Najafi, Moslem
2014-01-01
Purpose: This study was aimed to evaluate general toxicity, anti-oxidant activity and effects of Ficus carica leaves extract on ischemia/reperfusion injuries. Methods: Antioxidant activity, total phenolic and flavonoid compounds of 70% methanolic extract of Ficus carica leaves were measured. The general toxicity test was carried out by brine shrimp lethality assay. Isolated hearts of male rats were mounted on a Langendorff apparatus and perfused with modified Krebs-Henseleit solution. In control group, the hearts were perfused with normal Krebs solution, however, treatment groups received enriched solution with the extract (0.04, 0.2 and 1 mg/ml) during stabilization and reperfusion (after 30 min global ischemia), respectively. Cardiac arrhythmias were analyzed and TTC method was used for infarct size determination. Results: The extract displayed antioxidant activity in the DPPH assay (RC50=0.06666 mg/ml). Total phenolic content was 12.29 mg GAE/100 g dry sample and the amount of flavonoids was calculated 40.729 mg/g. LD50 value by brine shrimp test was 0.158 mg/ml. The extract decreased number of VEBs, incidence and duration of Rev VF with clear reduction in infarct size and infarct volume (P<0.001). Conclusion: Ficus carica decreased ischemia/reperfusion-induced injuries. These protections are probably due to antioxidant capacity and the existence of flavonoid and phenolic compounds in the extract. PMID:25671192
2010-03-18
Grignard reagent was added drop-wise to a well-stirred THF solution (10 mL) of trichloromethylsilane (5.431 g, 36.3 mmol) in a 250 mL flask. After...chloromethylsilane) The Grignard reagent , (Me3Si)2NC6H4MgBr was prepared exactly as previously described from 37.6 mmol of magnesium and 30 mmol of (N...trimethylsilyl)2-4-bromoaniline in THF (25 mL). This Grignard reagent was added drop-wise to a well-stirred THF solution (10 mL) of trichloromethylsilane
Rodríguez-Gómez, R; Jiménez-Díaz, I; Zafra-Gómez, A; Morales, J C
2015-11-01
A simple and reliable method for the determination of the fructooligosaccharides (FOS) kestose (GF2), nystose (GF3), fructofuranosylnystose (GF4), in the presence of fructose, glucose and lactose in dairy products is proposed. The most relevant advantages of the proposed method are the simultaneous determination of the most common FOS in enriched products and a reduction of the time required for sample treatment since the method consists merely in addition of a precipitation solution for the removal of lipids and proteins. Furthermore, the method saves a substantial amount of reagents compared with other methods and sample manipulation is reduced. Two chromatographic separations are proposed. The first one is carried out on an amino phase column for liquid chromatography with refractive index detection (HPLC-RI) (concentration of analytes higher than 0.1 mg mL(-1)) and the second one on an anion-exchange Carbopac PA-1 column for high-performance anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD) (concentration of FOS lower than 0.1 mg mL(-1)). The method was validated by recovery assays with spiked samples using matrix-matched calibration. The limits of quantification of the method ranged from 1.2 to 2.0 µg mL(-1) for HPAEC-PAD and from 140 to 200 µg mL(-1) for HPLC-RI, while inter- and intra-day variability was under 3.5% in all cases. The proposed method was applied to the determination of compounds in supplemented milk, infant formulas and milk related juices with good recoveries in all cases. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Rutao; Yang, Jinghe; Wu, Xia; Sun, Changxia
2002-02-01
The interaction of berberine with nucleic acid in the presence of cetyltrimethylammonium bromide (CTMAB) in aqueous solution has been studied by spectrophotometry and resonance light scattering (RLS) spectroscopy. At pH 7.30, the RLS signals of berberine were greatly enhanced by nucleic acid in the region of 300-600 nm characterized by four peaks at 324.0, 386.5, 416.5 and 465.0 nm. The binding properties were examined by using a Scatchard plot based on the measurement of enhanced RLS data at 416.5 nm. Under optimum conditions, the increase of RLS intensity of this system at 416.5 nm is proportional to the concentration of nucleic acid. The linear range is 7.5×10 -9-7.5×10 -5 g ml -1 for calf thymus DNA, 7.5×10 -9-2.5×10 -5 g ml -1 for herring sperm DNA, and 5.0×10 -9-2.5×10 -5 g ml -1 for yeast RNA. The detection limits (S/N=3) are 2.1 ng ml -1 for calf thymus DNA, 6.5 ng ml -1 for herring sperm DNA and 3.5 ng ml -1 for yeast RNA, respectively. Three synthetic samples were analyzed satisfactorily.
Chromium speciation in environmental samples using a solid phase spectrophotometric method.
Amin, Alaa S; Kassem, Mohammed A
2012-10-01
A solid phase extraction technique is proposed for preconcentration and speciation of chromium in natural waters using spectrophotometric analysis. The procedure is based on sorption of chromium(III) as 4-(2-benzothiazolylazo)2,2'-biphenyldiol complex on dextran-type anion-exchange gel (Sephadex DEAE A-25). After reduction of Cr(VI) by 0.5 ml of 96% concentrated H(2)SO(4) and ethanol, the system was applied to the total chromium. The concentration of Cr(VI) was calculated as the difference between the total Cr and the Cr(III) content. The influences of some analytical parameters such as: pH of the aqueous solution, amounts of 4-(2-benzothiazolylazo)2,2'-biphenyldiol (BTABD), and sample volumes were investigated. The absorbance of the gel, at 628 and 750 nm, packed in a 1.0 mm cell, is measured directly. The molar absorptivities were found to be 2.11×10(7) and 3.90×10(7) L mol(-1)cm(-1) for 500 and 1000 ml, respectively. Calibration is linear over the range 0.05-1.45 μg L(-1) with RSD of <1.85% (n=8.0). Using 35 mg exchanger, the detection and quantification limits were 13 and 44 ng L(-1) for 500 ml sample, whereas for 1000 ml sample were 8.0 and 27 ng L(-1), respectively. Increasing the sample volume can enhance the sensitivity. No considerable interferences have been observed from other investigated anions and cations on the chromium speciation. The proposed method was applied to the speciation of chromium in natural waters and total chromium preconcentration in microwave digested tobacco, coffee, tea, and soil samples. The results were simultaneously compared with those obtained using an ET AAS method, whereby the validity of the method has been tested. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Hu, Li; Zhao, Nanjing; Liu, Wenqing; Meng, Deshuo; Fang, Li; Wang, Yin; Yu, Yang; Ma, Mingjun
2015-08-01
Heavy metals in water can be deposited on graphite flakes, which can be used as an enrichment method for laser-induced breakdown spectroscopy (LIBS) and is studied in this paper. The graphite samples were prepared with an automatic device, which was composed of a loading and unloading module, a quantitatively adding solution module, a rapid heating and drying module and a precise rotating module. The experimental results showed that the sample preparation methods had no significant effect on sample distribution and the LIBS signal accumulated in 20 pulses was stable and repeatable. With an increasing amount of the sample solution on the graphite flake, the peak intensity at Cu I 324.75 nm accorded with the exponential function with a correlation coefficient of 0.9963 and the background intensity remained unchanged. The limit of detection (LOD) was calculated through linear fitting of the peak intensity versus the concentration. The LOD decreased rapidly with an increasing amount of sample solution until the amount exceeded 20 mL and the correlation coefficient of exponential function fitting was 0.991. The LOD of Pb, Ni, Cd, Cr and Zn after evaporating different amounts of sample solution on the graphite flakes was measured and the variation tendency of their LOD with sample solution amounts was similar to the tendency for Cu. The experimental data and conclusions could provide a reference for automatic sample preparation and heavy metal in situ detection. supported by National Natural Science Foundation of China (No. 60908018), National High Technology Research and Development Program of China (No. 2013AA065502) and Anhui Province Outstanding Youth Science Fund of China (No. 1108085J19)
Effect of Passive Ultrasonic Irrigation on Enterococcus faecalis from Root Canals: An Ex Vivo Study.
Guerreiro-Tanomaru, Juliane Maria; Chávez-Andrade, Gisselle Moraima; de Faria-Júnior, Norberto Batista; Watanabe, Evandro; Tanomaru-Filho, Mário
2015-01-01
Endodontic irrigation aims to clean and disinfect the root canal system. Passive ultrasonic irrigation (PUI) is based on the use of an ultrasound-activated instrument into the root canal filled with irrigant. The aim of this study was to evaluate, ex vivo, the effectiveness of PUI in eliminating Enterococcus faecalis from root canals. Seventy-five extracted human single-root teeth were used. After root canal preparation, specimens were inoculated with E. faecalis and incubated at 37 °C for 21 days. Specimens were distributed into five groups (n=15), according to the irrigation method: PUI + saline solution (PUI/SS); PUI + 1% NaOCl (PUI/NaOCl); conventional needle irrigation (CNI) + saline solution (CNI/SS); CNI + 1% NaOCl (CNI/NaOCl); No irrigation (control). Microbiological samples were collected at three time points: initial (21 days after inoculation), post-irrigation (immediately after irrigation), and final (7 days after irrigation). Data were obtained in CFU mL-1 and subjected to analysis by ANOVA and Tukey's tests at 5% significance level. The post-irrigation samples did not demonstrate statistical difference between PUI/SS and CNI/SS nor between PUI/NaOCl and CNI/NaOCl (p>0.05), but PUI/NaOCl and CNI/NaOCl had lower CFU mL-1 number than the other groups (p>0.05). Statistically significant difference was observed between the initial and post-irrigation samples and between the post-irrigation and final samples (p<0.05) in all groups, except in the control. The final samples of all groups presented bacterial counts similar to the initial samples. PUI or CNI with 1% NaOCl contribute to disinfection, but are unable to eradicate E. faecalis from the root canal system.
Hossain, Mirza Akram; Friciu, Mihaela; Aubin, Sebastien; Leclair, Grégoire
2014-04-15
The stability of penicillin G sodium solutions stored in polyvinyl chloride (PVC) bags or elastomeric pump containers was studied. Test samples were prepared by diluting powdered penicillin G sodium (10 million units/10-mL vial) to solutions of 2,500 or 50,000 units/mL with 0.9% sodium chloride injection or 5% dextrose injection. The preparations were transferred to 250-mL PVC bags and elastomeric pump containers. All samples were prepared in triplicate and stored at 5°C. Chemical stability was measured by a stability-indicating high-performance liquid chromatographic (HPLC) assay and by pH evaluation. Particulate matter was evaluated according to compendial standards using a light-obscuration particle count test. Preparations were visually examined throughout the study. After 21 days of storage, all test samples remained chemically stable, with an HPLC assay recovery value of more than 90% of the initial value. After 28 days, all samples prepared with either diluent and stored in PVC bags, as well as the samples diluted to 2,500 units/mL with sodium chloride injection and stored in elastomeric pump containers, did not meet the recovery acceptance limit. For all test samples, the mean pH consistently decreased during storage, from about 6.4 to about 5.5. Particle counts remained acceptable throughout the study, and no change in appearance was observed. Penicillin G for injection (2,500 and 50,000 units/mL) diluted in 0.9% sodium chloride injection or 5% dextrose injection and stored at 5°C in PVC containers or elastomeric pump containers was physically and chemically stable for a period of at least 21 days.
Kuroda, Noritaka; Hird, Nick; Cork, David G
2006-01-01
During further improvement of a high-throughput, solution-phase synthesis system, new workup tools and apparatus for parallel liquid-liquid extraction and evaporation have been developed. A combination of in-house design and collaboration with external manufacturers has been used to address (1) environmental issues concerning solvent emissions and (2) sample tracking errors arising from manual intervention. A parallel liquid-liquid extraction unit, containing miniature high-speed magnetic stirrers for efficient mixing of organic and aqueous phases, has been developed for use on a multichannel liquid handler. Separation of the phases is achieved by dispensing them into a newly patented filter tube containing a vertical hydrophobic porous membrane, which allows only the organic phase to pass into collection vials positioned below. The vertical positioning of the membrane overcomes the hitherto dependence on the use of heavier-than-water, bottom-phase, organic solvents such as dichloromethane, which are restricted due to environmental concerns. Both small (6-mL) and large (60-mL) filter tubes were developed for parallel phase separation in library and template synthesis, respectively. In addition, an apparatus for parallel solvent evaporation was developed to (1) remove solvent from the above samples with highly efficient recovery and (2) avoid the movement of individual samples between their collection on a liquid handler and registration to prevent sample identification errors. The apparatus uses a diaphragm pump to achieve a dynamic circulating closed system with a heating block for the rack of 96 sample vials and an efficient condenser to trap the solvents. Solvent recovery is typically >98%, and convenient operation and monitoring has made the apparatus the first choice for removal of volatile solvents.
Martens-Lobenhoffer, J
1999-08-01
A gas chromatographic-mass spectrometric (GC-MS) assay for the determination of thiopental and its main metabolite pentobarbital in human plasma is presented in this study. The sample preparation consists only in the addition of the internal standard barbital and an acidic extraction with ethyl acetate. Analytical separation is accomplished on a RTX-1 15 m x 0.25 mm capillary column with a film thickness of 0.5 micron. The effluent is observed by a mass selective detector operating in the single ion monitoring mode. The limits of detection are 5 ng/ml for pentobarbital and 10 ng/ml for thiopental, the intra-day variabilities are 2.2% and 4.0% and the inter-day variabilities are 3.3% and 7.1% at concentrations of 5 micrograms/ml, respectively. Applying this assay, the stability of thiopental and pentobarbital in human plasma was tested at concentrations of 5 micrograms/ml each. Thiopental is stable in human plasma at least over 41 days stored at -20 degrees C and 5 degrees C, respectively. A decay of about 2%/day is observed under storage at ambient temperature (19-20 degrees C). Pentobarbital is stable under all storage conditions. Methanolic solutions of thiopental are stable for 83 days under storage at 5 degrees C. Aqueous solutions of thiopental-sodium are stable for at least 23 days under storage at 5 degrees C or ambient temperature.
Investigation on V2O5 Thin Films Prepared by Spray Pyrolysis Technique
NASA Astrophysics Data System (ADS)
Anasthasiya, A. Nancy Anna; Gowtham, K.; Shruthi, R.; Pandeeswari, R.; Jeyaprakash, B. G.
The spray pyrolysis technique was employed to deposit V2O5 thin films on a glass substrate. By varying the precursor solution volume from 10mL to 50mL in steps of 10mL, films of various thicknesses were prepared. Orthorhombic polycrystalline V2O5 films were inferred from the XRD pattern irrespective of precursor solution volume. The micro-Raman studies suggested that annealed V2O5 thin film has good crystallinity. The effect of precursor solution volume on morphological and optical properties were analysed and reported.
Khan, Sumaira; Kazi, Tasneem G; Baig, Jameel A; Kolachi, Nida F; Afridi, Hassan I; Wadhwa, Sham Kumar; Shah, Abdul Q; Kandhro, Ghulam A; Shah, Faheem
2010-10-15
A cloud point extraction (CPE) method has been developed for the determination of trace quantity of vanadium ions in pharmaceutical formulations (PF), dialysate (DS) and parenteral solutions (PS). The CPE of vanadium (V) using 8-hydroxyquinoline (oxine) as complexing reagent and mediated by nonionic surfactant (Triton X-114) was investigated. The parameters that affect the extraction efficiency of CPE, such as pH of sample solution, concentration of oxine and Triton X-114, equilibration temperature and time period for shaking were investigated in detail. The validity of CPE of V was checked by standard addition method in real samples. The extracted surfactant-rich phase was diluted with nitric acid in ethanol, prior to subjecting electrothermal atomic absorption spectrometry. Under these conditions, the preconcentration of 50 mL sample solutions, allowed raising an enrichment factor of 125-fold. The lower limit of detection obtained under the optimal conditions was 42 ng/L. The proposed method has been successfully applied to the determination of trace quantity of V in various pharmaceutical preparations with satisfactory results. The concentration ranges of V in PF, DS and PS samples were found in the range of 10.5-15.2, 0.65-1.32 and 1.76-6.93 microg/L, respectively. 2010 Elsevier B.V. All rights reserved.
Particulate-matter content of 11 cephalosporin injections: conformance with USP limits.
Parkins, D A; Taylor, A J
1987-05-01
The particulate-matter content of 11 dry-powder cephalosporin injections was determined using a modified version of the official United States Pharmacopeial Convention (USP) method for particulate matter in small-volume injections (SVIs). Ten vials of each cephalosporin product were each constituted with 10 mL of Water for Injections BP that had been filtered through a 0.22-micron membrane. The pooled contents of the 10 vials for each product were allowed to stand under reduced pressure to ensure removal of gas bubbles. Particulate-matter content was determined using a HIAC/Royco particle counter on six 10-mL samples obtained from the pooled solutions for each product. All solution preparation and particle counting was performed in a horizontal-laminar-airflow hood. Modifications of the USP method used in this study included the use of six rather than two samples from each pooled solution, the addition of diluent to the injections through the rubber closure with a needle instead of into the open container, and changes in the degassing method. Particle counts for all products examined were lower than USP limits for SVIs. All but two products contained less than 15% of USP limits for particles greater than or equal to 10 microns in effective diameter and particles greater than or equal to 25 microns in effective diameter. The standard USP method for degassing (standing for two minutes) was inadequate. Application of reduced pressure for up to 10 minutes was necessary for thorough degassing of products.(ABSTRACT TRUNCATED AT 250 WORDS)
Stability of Alprostadil in 0.9% Sodium Chloride Stored in Polyvinyl Chloride Containers.
McCluskey, Susan V; Kirkham, Kylian; Munson, Jessica M
2017-01-01
The stability of alprostadil diluted in 0.9% sodium chloride stored in polyvinyl chloride (VIAFLEX) containers at refrigerated temperature, protected from light, is reported. Five solutions of alprostadil 11 mcg/mL were prepared in 250 mL 0.9% sodium chloride polyvinyl chloride (PL146) containers. The final concentration of alcohol was 2%. Samples were stored under refrigeration (2°C to 8°C) with protection from light. Two containers were submitted for potency testing and analyzed in duplicate with the stability-indicating high-performance liquid chromatography assay at specific time points over 14 days. Three containers were submitted for pH and visual testing at specific time points over 14 days. Stability was defined as retention of 90% to 110% of initial alprostadil concentration, with maintenance of the original clear, colorless, and visually particulate-free solution. Study results reported retention of 90% to 110% initial alprostadil concentration at all time points through day 10. One sample exceeded 110% potency at day 14. pH values did not change appreciably over the 14 days. There were no color changes or particle formation detected in the solutions over the study period. This study concluded that during refrigerated, light-protected storage in polyvinyl chloride (VIAFLEX) containers, a commercial alcohol-containing alprostadil formulation diluted to 11 mcg/mL with 0.9% sodium chloride 250 mL was stable for 10 days. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Kulshrestha, Pankaj; McKinstry, Katherine C; Fernandez, Bernadette O; Feelisch, Martin; Mitch, William A
2010-05-01
Although N-nitrosodimethylamine (NDMA) has been the most prevalent N-nitrosamine detected in disinfected waters, it remains unclear whether NDMA is indeed the most significant N-nitrosamine or just one representative of a larger pool of N-nitrosamines. A widely used assay applied to quantify nitrite, S-nitrosothiols, and N-nitrosamines in biological samples involves their reduction to nitric oxide by acidic tri-iodide, followed by chemiluminescent detection of the evolved nitric oxide in the gas phase. We here describe an adaptation of this method for analyzing total N-nitrosamine (TONO) concentrations in disinfected pools. Optimal sensitivity for N-nitrosamines was obtained using a reduction solution containing 13.5 mL glacial acetic acid and 1 mL of an aqueous 540 g/L iodide and 114 g/L iodine solution held at 80 degrees C. The method detection limit for N-nitrosamines was 110 nM using 100 microL sample injections and NDMA as a standard. N-nitrosamines featuring a range of polarities were converted to nitric oxide with 75-103% efficiency compared to NDMA. Evaluation of potential interfering species indicated that only nitrite and S-nitrosothiols were a concern, but both interferences were effectively eliminated using group-specific sample pretreatments previously employed for biological samples. To evaluate the low TONO concentrations anticipated for pools, 1 L samples were extracted by continuous liquid-liquid extraction with ethyl acetate for 24 h, and concentrated to 1 mL. N-nitrosamine recovery during extraction ranged from 37-75%, and there was a potential for artifactual nitrosation of amines during solvent reflux in the presence of significant nitrite concentrations, but not at the low nitrite concentrations prevalent in most pools. Using the 1000-fold concentration factor and 56% average extraction efficiency, the method detection limit would be 62 pM (5 ng/L as NDMA). The TONO assay was applied to six pools and their common tap water source in conjunction with analysis for specific nitrosamines. Even accounting for the range of N-nitrosamine extraction recoveries, NDMA accounted for an average of only 13% (range 3-46%) of the total nitrosamine pool.
Efficacy of detergents in removing Salmonella and Shigella spp. from the surface of fresh produce.
Raiden, Renee M; Sumner, Susan S; Eifert, Joseph D; Pierson, Merle D
2003-12-01
Fresh produce has been implicated in several foodborne disease outbreaks. Produce surfaces can be primary sites of contamination during production and handling. One approach to reduce contamination is to treat fresh produce with rinsing agents. In this study, different detergent agents were used at 22 and 40 degrees C to determine their efficacy in removing Salmonella and Shigella spp. from the surfaces of strawberries, tomatoes, and green-leaf lettuce. Produce was inoculated at 22 degrees C with a cocktail of nalidixic acid-resistant organisms (6 to 6.5 log CFU/ml). After air drying for 1 h, samples were rinsed with either 0.1% Tween 80, 0.1% sodium lauryl sulfate (SLS), or water (control) at 22 or 40 degrees C. Rinse solutions were spiral plated onto tryptic soy agar supplemented with 50 mg of nalidixic acid per liter. In trials involving strawberries and lettuce, Salmonella and Shigella were removed at levels of 4 and 3 log CFU/ml, respectively, except from Salmonella-inoculated strawberries rinsed with SLS, for which minimal removal rates were 1.5 log CFU/ml at 22 degrees C and < 1 log CFU/ml at 40 degrees C. When whole strawberries were analyzed after rinsing with SLS, few organisms were recovered. This result suggests that SLS may have a lethal or sublethal effect on Salmonella, especially when a 40 degrees C solution is used. Salmonella and Shigella removal rates for tomatoes were 1 and 1.5 log CFU/ml lower, respectively, than those for strawberries or lettuce. Overall, detergents were no more effective in removing organisms from produce than water was. The detergents examined would not constitute effective overall produce rinse treatments.
Hua, Fei; Zhang, Pingping; Zhang, Fuli; Zhao, Yong; Li, Chunfeng; Sun, Chongyun; Wang, Xiaochen; Yang, Ruifu; Wang, Chengbin; Yu, Ailian; Zhou, Lei
2015-11-26
Francisella tularensis is a potential biowarfare/bioterrorism agent and zoonotic pathogen that causes tularemia; thus, surveillance of F. tularensis and first-level emergency response using point-of-care testing (POCT) are essential. The UPT-LF POCT assay was established to quantitatively detect F. tularensis within 15 min, and the sensitivity of the assay was 10(4) CFU · mL(-1) (100 CFU/test). The linear quantitative range covered five orders of magnitude, and the coefficients of variation were less than 10%. Except Shigella dysenteriae, UPT-LF showed excellent specificity to four strains that are also potential biowarfare/bioterrorism agents and 13 food-borne pathogenic strains. Samples with pH 2-13, high ion strengths (≥ 2 mol · L(-1) solution of KCl and NaCl), high viscosities (≤ 50 mg · mL(-1) PEG20000 or ≥ 20% glycerol), and high concentrations of biomacromolecules (≥ 400 mg · mL(-1) bovine serum albumin or ≥ 80 mg · mL(-1) casein) showed little influence on the assay. For practical utilization, the tolerance limits for seven powders and eight viscera were determined, and operation errors of liquid measurement demonstrated a minor influence on the strip. Ftu-UPT-LF is a candidate POCT method because of its excellent sensitivity, specificity, and stability in complex samples, as well as low operation error.
Compatibility and activity of enoxaparin sodium in 0.9% sodium chloride injection for 48 hours.
Mewborn, A L; Kessler, J M; Joyner, K A
1996-01-15
The stability of enoxaparin sodium in 0.9% sodium chloride injection in polyvinyl chloride (PVC) containers was studied. Triplicate solutions of 120 mg (1.2 mL) of enoxaparin (as the sodium salt) and 98.8 mL of 0.9% sodium chloride injection were prepared in 250-mL PVC containers and stored at room temperature (20-22 degrees C). Samples were taken immediately after preparation and at 0.25, 0.5, 0.75, 1, 4, 12, 16, 24, and 48 hours. Inspections for color change and precipitation were performed with a clarity inspection station and a magnifying glass. Samples of the three admixtures were evaluated in duplicate for pharmacologic activity by an automated coagulation heparin assay. Throughout the 48-hour study period, the enoxaparin admixtures were free of color change, evolution of gas, and precipitates. The pharmacologic activity of enoxaparin in the PVC containers remained > 94% of the initial measured activity for 48 hours. Enoxaparin 1.2 mg/mL (as the sodium salt) in 0.9% sodium chloride injection in PVC containers was stable for up to 48 hours at 20-22 degrees C.
NASA Astrophysics Data System (ADS)
Pourreza, Nahid; Lotfizadeh, Neda; Golmohammadi, Hamed
2018-03-01
In this research, a new colorimetric method for the determination of oxalate using curcumin nanoparticles (CURNs) in the presence Fe (III) is introduced. The method is based on the inhibitory effect of oxalate ion on the reaction of (CURNs) with Fe (III) in acidic media. This reaction was monitored by measuring the increase in absorbance of CURNs-Fe3 + complex in the presence of oxalate ion at 427 nm. The effect of different parameters such as the pH of the sample solution, concentration of Fe (III), concentration of CURNs and the reaction time was examined and optimized. Under optimum experimental conditions, the absorption intensity was linear with the concentration of oxalate in the range of 0.15 to 1.70 μg mL- 1. The limit of detection (LOD) was 0.077 μg mL- 1 and the relative standard deviations (RSD) for 8 replicate measurements of 0.40 and 1.05 μg mL- 1 of oxalate were 4.20% and 2.74%, respectively. The developed method was successfully employed to the determination of oxalate in water, food and urine samples with satisfactory results.
Vitamin E-coated membrane dialyzer and beta2-microglobulin removal.
Mandolfo, S; Bucci, R; Imbasciati, E
2003-12-01
This study was designed to test the removal of beta2-microglobulin (beta2M) in a vitamin E-modified membrane. We investigated in vivo the dialyzer (Excebrane, series EE, 1.8 m2) with respect to hydraulic permeability (Kuf), maximum ultrafiltration rate (UF max), sieving coefficient (Sc), and solute clearances in hemodialysis (HD) and in soft hemodiafiltration (HDF). Kuf was 18.4 ml/h/mmHg, UF max was 75 ml/min, and Sc for beta2M was 0.45. Clearance values at 400 ml/min of Qb in HD were 258 ml/min for urea, 201 ml/min for creatinine, and 135 ml/min for phosphate. In soft HDF, clearances were slightly higher. beta2M clearance was 26 ml/min in HD and 43 ml/min in soft HDF. In conclusion, Excebrane (series EE) procures a soft HDF with an amount of substitution fluid in post dilution mode of over 60 ml/min. Remarkable small solute clearances were obtained when the blood flow was raised to 400 ml/min. A significant reduction of beta2M is demonstrated by HDF.
Storage of red blood cells with improved maintenance of 2,3-bisphosphoglycerate.
Högman, Claes F; Löf, Helena; Meryman, Harold T
2006-09-01
During storage, red blood cells (RBCs) rapidly lose 2,3-bisphosphoglycerate (2,3-DPG) leading to an increase in the affinity for O(2) and a temporary impairment of O(2) transport. Recent clinical evaluations indicate that the quality of transfused RBCs may be more important for patient survival than previously recognized. Glucose-free additive solutions (ASs) were prepared with sodium citrate, sodium gluconate, adenine, mannitol, and phosphates at high pH, a solution that can be heat-sterilized. CP2D was used as an anticoagulant. Additional CP2D was added to the AS to supply glucose. RBCs were stored at 4 degrees C and assayed periodically for intracellular pH (pHi), extracellular pH, glucose, lactate, phosphate, ATP, 2,3-DPG, hemolysis, and morphology. Storage in 175 mL of the chloride-free, hypotonic medium at a hematocrit (Hct) level of 59 to 60 percent resulted in an elevated pHi and the maintenance of 2,3-DPG at or above the initial value for 2 weeks without loss of ATP. The addition of 400 mL of storage solution followed by centrifugation and removal of 300 mL of excess solution to a Hct level of 60 to 66 percent further reduced the chloride concentration, resulting in the maintenance of 2,3-DPG for 4 weeks. Hemolysis was at 0.1 percent at 6 weeks. Improvements in the maintenance of 2,3-DPG were achieved with 175 mL of a chloride-free storage solution with familiar additives at nontoxic concentrations to increase pHi. Adding, instead, 400 mL of storage solution followed by the removal of 300 mL reduced the chloride concentration, increasing the pHi and extending the maintenance of 2,3-DPG to 4 weeks.
Sheikhian, Leila; Bina, Sedigheh
2016-01-15
In this study, ionic liquid-modified silica was used as sorbent for simultaneous extraction and preconcentration of 3-indole butyric acid and 3-indole acetic acid in pea plants. The effect of some parameters such as pH and ionic strength of sample solution, amount of sorbent, flow rate of aqueous sample solution and eluent solution, concentration of eluent solution, and temperature were studied for each hormone solution. Percent extraction of 3-indole butyric acid and 3-indole acetic acid was strongly affected by pH of aqueous sample solution. Ionic strength of aqueous phase and temperature showed no serious effects on extraction efficiency of studied plant hormones. Obtained breakthrough volume was 200mL for each of studied hormones. Preconcentration factor for spectroscopic and chromatographic determination of studied hormones was 100 and 4.0×10(3) respectively. Each solid sorbent phase was reusable for almost 10 times of extraction/stripping procedure. Relative standard deviations of extraction/stripping processes of 3-indole butyric acid and 3-indole acetic acid were 2.79% and 3.66% respectively. The calculated limit of detections for IBA and IAA were 9.1×10(-2)mgL(-1) and 1.6×10(-1)mgL(-1) respectively. Copyright © 2015 Elsevier B.V. All rights reserved.
Takeda, Kazuhiko; Katoh, Shinya; Nakatani, Nobutake; Sakugawa, Hiroshi
2006-12-01
The aim of this research was to develop a simple procedure for a highly sensitive determination of low-molecular-weight (LMW) carbonyl compounds in drinking water and natural water. We employed a preconcentration HPLC system with 2,4-dinitrophenylhydrazine (DNPH) for the determination of LMW carbonyl compounds. A C-18 reverse-phase preconcentration column was used instead of a sample loop at the sample injection valve. A 0.1 - 5.0 mL portion of the derivatized sample solution was injected with a gas-tight syringe, and a 15% acetonitrile aqueous solution was pushed through the preconcentration column to remove the unreacted excess DNPH, which caused serious interference in the determination of formaldehyde. The detection limits were 1 - 3 nM with a relative standard deviation of 2 - 5% for 20 nM standard solutions (n = 5). The calibration curves were essentially unaffected by coexisting sea salts. Applications to commercial mineral water, tap water, river water, pond water and seawater are presented.
Arantes de Carvalho, Gabriel G; Kondaveeti, Stalin; Petri, Denise F S; Fioroto, Alexandre M; Albuquerque, Luiza G R; Oliveira, Pedro V
2016-12-01
Analytical methods for the determination of rare earth elements (REE) in natural waters by plasma spectrochemical techniques often require sample preparation procedures for analytes preconcentration as well as for removing matrix constituents, that may interfere on the analytical measurements. In the present work, calcium alginate (CA) beads were used for the first time aiming at Ce, La and Nd preconcentration from groundwater samples for further determination by inductively coupled plasma optical emission spectrometry (ICP OES). Test samples were analyzed in batch mode by transferring a 40mL test portion (pH=5±0.2) into a 50mL polyethylene flask containing 125mg CA beads. After 15min contact, the analytes were quantitatively extracted from the loaded CA beads with 2.0mL of 1.0molL -1 HCl solution for further determination by ICP OES, using Ce (II) 456.236, La (II) 379.478 and Nd (II) 430.358nm emission lines. The proposed approach is a reliable alternative for REE single-stage preconcentration from aqueous samples, as it provided accurate results based on the addition and recovery analysis of groundwater. The results obtained by the proposed method were also compared with those from reference method based on inductively coupled plasma mass spectrometry (ICP-MS) and no significant differences were observed after applying the Student's t-test at 95% confidence level. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghodgaonkar, D.K.
1987-01-01
A new method, namely, modified infinite sample method, has been developed which is particularly suitable for millimeter-wave dielectric measurements of biological materials. In this method, an impedance transformer is used which reduces the reflectivity of the biological sample. Because of the effect of introducing impendance transformer, the measured reflection coefficients are more sensitive to the complex permittivities of biological samples. For accurate measurement of reflection coefficients, two automated measurment systems were developed which cover the frequencies range of 26.5-60 GHz. An uncertainty analysis was performed to get an estimate of the errors in the measured complex permittivities. The dielectric propertiesmore » were measured for 10% saline solution, whole human blood, 200 mg/ml bovine serum albumin (BSA) solution and suspension of Saccharomyces cerevisiae cells. The Maxwell-Fricke equation, which is derived from dielectric mixture theory, was used for determination bound water in BSA solution. The results of all biological samples were interpreted by fitting Debye relaxation and Cole-Cole model. It is observed that the dielectric data for the biological materials can be explained on the basis of Debye relaxation of water molecule.« less
Di Sabatino, Marcello; Di Pietra, Anna Maria; Benfenati, Luigi; Di Simone, Bruno
2007-01-01
A liquid chromatography (LC) method is described for the simultaneous determination of 10 commonly used sulfonamide drug residues in meat. The 10 sulfonamide drugs of interest were sulfadiazine, sulfathiazole, sulfamerazine, sulfadimidine, sulfamethizole, sulfamonomethoxine, sulfachloropyridazine, sulfadoxine, sulfadimethoxine, and sulfaquinoxaline. The residues were extracted with acetone-chloroform (1 + 1). Sulfonamides were quantitatively retained in the extracting solution and afterwards eluted from a cation-exchanger solid-phase extraction cartridge with a solution of methanol-aqueous ammonia. The solution was dried, reconstituted with 5 mL methanol and filtered before analysis by LC-ultraviolet using a C18 column with a mobile phase gradient of potassium dihydrogen phosphate buffer, pH 2.5, and methanol-acetonitrile (30 + 70, v/v). The method was applied to cattle, swine, chicken, and sheep muscle tissues. The validation was performed with a fortified cattle meat sample at level of 100 ppb, which is the administrative maximum residue limit for sulfonamides in the European Union. The limit of quantitation for all sulfonamides was between 3 and 14 ppb. Recovery was evaluated for different meat matrixes. The mean recovery values were between 66.3% for pork meat samples and 71.5% for cattle meat samples.
Benett, William J.; Krulevitch, Peter A.
2001-01-01
A miniature connector for introducing microliter quantities of solutions into microfabricated fluidic devices, and which incorporates a molded ring or seal set into a ferrule cartridge, with or without a compression screw. The fluidic connector, for example, joins standard high pressure liquid chromatography (HPLC) tubing to 1 mm diameter holes in silicon or glass, enabling ml-sized volumes of sample solutions to be merged with .mu.l-sized devices. The connector has many features, including ease of connect and disconnect; a small footprint which enables numerous connectors to be located in a small area; low dead volume; helium leak-tight; and tubing does not twist during connection. Thus the connector enables easy and effective change of microfluidic devices and introduction of different solutions in the devices.
Salem, Alaa A; Mossa, Hussein A
2012-01-15
Selective, rapid and accurate quantitative proton nuclear magnetic resonance (qHNMR) method for the determination of levofloxacin, metronidazole benzoate and sulfamethoxazole in aqueous solutions was developed and validated. The method was successfully applied to the determinations of the drugs and their admixtures in pharmaceutical, urine and plasma samples. Maleic acid and sodium malate were used as internal standards. Effect of temperature on spectral measurements was evaluated. Linear dynamic ranges of 0.50-68.00, 0.13-11.30 and 0.24-21.00 mg per 0.60 mL solution were obtained for levofloxacin, metronidazole benzoate and sulfamethoxazole, respectively. Average recovery % in the range of 96.00-104.20 ± (0.17-2.91) was obtained for drugs in pure, pharmaceutical, plasma and urine samples. Inter and intra-day analyses gave average recoveries % in the ranges 96.10-98.40 ± (1.68-2.81) and 96.00-104.20 ± (0.17-2.91), respectively. Instrumental detection limits ≤0.03 mg per 0.6 mL were obtained for the three drugs. Developed method has demonstrated high performance characteristics for analyzing investigated drugs and their admixtures. Student t-test at 95% confidence level revealed insignificant bias between the real and measured contents of investigated drugs in pure, pharmaceutical, urine and plasma samples and its admixtures. Application of the statistical F-test revealed insignificant differences in precisions between the developed method and arbitrary selected reference methods. Copyright © 2011 Elsevier B.V. All rights reserved.
An improved method for high precision measurement of chromium isotopes using double spike MC-ICP-MS
NASA Astrophysics Data System (ADS)
Zhu, J.; Wu, G. L.; Wang, X.; Zhang, L. X.; Han, G.
2017-12-01
Chormium(Cr) isotopes have been used to trace pollution processes and reconstruct paleo-redox conditions. However, the precise determination of Cr isotopes has still been challenged due to difficulties in purifying Cr from samples with low Cr content and complex matrices. Here we report an improved four-step column chromatographic procedure to separate Cr from matrix elements. Firstly, Cr in sample solution was mixed with 50Cr-54Cr double spike (the optimized 54Crspike/52Crsample = 0.4 and (50Cr/54Cr)spike = 1.3:1) was completely converted into Cr (III) in 8.5mol/L HCl and loaded onto 2ml of AG50W-X8(200-400m) resin conditioned with 11 mol/L HCl. The 2.65ml of eluent was adjusted to 4.5ml of 6mol/L HCl and immediately loaded onto a Bio-Rad column filled with 2ml of AG1-X8 anion resin (100-200m). These two steps can remove at least 99% of Ca, Fe and most matrix elements. Secondly, the 7.5ml of eluent was dried down and dissolved in 0.1ml of 0.5mol/L HNO3.before adding 2ml 4mol/L HF, which was then loaded onto 1ml of AG1-X8 anion resin (100-200m) to remove Ti and V. Finally, sample was dissolved in 0.1ml of 0.5 mol/L HNO3 and oxidized by 0.5mL 0.2 mol/L (NH4)2S2O8 and 4.4mL H2O, which was then centrifuged to remove Mn oxide, and supernatant was loaded onto AG1-X8 resin to remove SO42-, Ni, Al, Na and some Mg using 8ml H2O and 3ml 2mol/L HCl. Cr was eluted by 2 mol/L HNO3 containing 5% H2O2 and the dried Cr was dissolved in 3% HNO3for isotopic analysis. The total yield to Cr is great than 80% even for samples with low Cr content. Chromium isotopes was measured on a Neptune plus MC-ICP-MS in China University of Geosciences(Beijing). Using our improved method, the δ53/52CrSRM979 values of USGS reference materials BHVO-2, BCR-2 and SGR-1b are -0.12±0.06‰(n=15), -0.09±0.06‰ (n=5), and 0.30±0.06‰ (n=12), respectively, which agree well with previously reported values. The δ53/52CrSRM979 of carbonaceous shale CP0-1 and CP0-12 collected from Hubei, China are 2.05±0.08‰ (n=3) and 2.08±0.07‰ (n=3), respectively, identical to 2.17±0.08‰ and 2.14±0.08‰ determined at the Department of Geology, UIUC. This work was supported by the National Key Basic Research Program of China (2014CB238903) and the National Natural Science Foundation of China (41473028, 41273029).
Zhang, Hongyan; Wang, Lei; Zhang, Yan; Fang, Guozhen; Zheng, Wenjie; Wang, Shuo
2007-03-21
Direct competitive enzyme-linked immunosorbent assays (ELISA) were developed to detect a broad range of sulfonamides in various matrices. Screening for this class of antibiotics in pig muscle, chicken muscle, fish, and egg extracts was accomplished by simple, rapid extraction methods carried out with only phosphate-buffered saline (PBS) buffer. Twenty milliliters of extract solution was added to 4 g of sample to extract the sulfonamide residues, and sample extracts diluted with assay buffer were directly analyzed by ELISA; matrix effects could be avoided with 1:5 dilution of pig muscle, chicken muscle, and egg extracts with PBS and 1:5 dilution of fish extract with 1% bovine serum albumin (BSA)-PBS. For liver sample, the extraction method was a little more complicated; 2 g of sample was added to 20 mL of ethanol, mixed, and then centrifuged. The solvent of 10 mL of the upper liquid was removed, and the residues were dissolved in 10 mL of PBS and then filtered; the filtrate was diluted two-fold with 0.5% BSA-PBS for ELISA. These common methods were able to detect seven sulfonamide residues such as sulfisozole, sulfathiazole, sufameter, sulfamethoxypyridazine, sulfapyridine, sulfamethizole, and sulfachlorpyridazine in pig muscle, liver, chicken muscle, egg, and fish. The assay's detection limits for these compounds were less than 100 microg kg-1. Various extraction methods were tested, and the average recovery (n=3) of 100 microg kg-1 for the matrices was found to range from 77.3 to 123.7%.
Amlashi, Nadiya Ekbatani; Hadjmohammadi, Mohammad Reza; Nazari, Seyed Saman Seyed Jafar
2014-09-26
For the first time, a novel water-contained surfactant-based vortex-assisted microextraction method (WSVAME) was developed for the extraction of two synthetic antioxidants (t-butyl hydroquinone (TBHQ) and butylated hydroxyanisole (BHA)) from edible oil samples. The novel microextraction method is based on the injection of an aqueous solution of non-ionic surfactant, Brij-35, into the oil sample in a conical bottom glass tube to form a cloudy solution. Vortex mixing was applied to accelerate the dispersion process. After extraction and phase separation by centrifugation, the lower sediment phase was directly analyzed by HPLC. The effects of the four experimental parameters including volume and concentration of extraction solvent (aqueous solution of Brij-35), percentage of acetic acid added to the oil sample and vortex time on the extraction efficiency were studied with a full factorial design. The central composite design and multiple linear regression method were applied for the construction of the best polynomial model based on experimental recoveries. The proposed method showed good linearity within the range of 0.200-200 μg mL(-1), the square of correlation coefficient higher than 0.999 and appropriate limit of detection (0.026 and 0.020 μg mL(-1) for TBHQ and BHA, respectively), while the precision for inner-day was ≤ 3.0 (n=5) and it was ≤ 3.80 (n=5) for inter-day assay. Under the optimal condition (30 μL of 0.10 mol L(-1) Brij-35 solution as extraction solvent and vortex time 1 min), the method was successfully applied for determination of TBHQ and BHA in different commercial edible oil samples. The recoveries in all cases were above 95%, with relative standard deviations below 5%. This approach is considered as a simple, sensitive and environmentally friendly method because of biodegradability of the extraction phase and no use of organic solvent in the extraction procedure. Copyright © 2014 Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) Each gram of soluble powder contains 450 milligrams (mg) tiamulin hydrogen fumarate. (2) Each milliliter (mL) of solution contains 125 mg (12.5 percent) tiamulin hydrogen fumarate. (3) Each mL of solution contains 123 mg (12.3 percent) tiamulin hydrogen fumarate. (b) Sponsors. See sponsor numbers in...
Code of Federal Regulations, 2014 CFR
2014-04-01
...) Each gram of soluble powder contains 450 milligrams (mg) tiamulin hydrogen fumarate. (2) Each milliliter (mL) of solution contains 125 mg (12.5 percent) tiamulin hydrogen fumarate. (3) Each mL of solution contains 123 mg (12.3 percent) tiamulin hydrogen fumarate. (b) Sponsors. See sponsor numbers in...
Code of Federal Regulations, 2012 CFR
2012-04-01
...) Each gram of soluble powder contains 450 milligrams (mg) tiamulin hydrogen fumarate. (2) Each milliliter (mL) of solution contains 125 mg (12.5 percent) tiamulin hydrogen fumarate. (3) Each mL of solution contains 123 mg (12.3 percent) tiamulin hydrogen fumarate. (b) Sponsors. See sponsor numbers in...
Desmaris, Romain-Pacôme; Mercier, Lionel; Paci, Angelo
2015-09-01
Melphalan is an alkylating agent frequently used in an intravenous formulation to treat hematologic malignancies and solid tumors in both adults and children. According to the manufacturer, melphalan is stable in sterile 0.9% sodium chloride for 90 min at room temperature (RT). Several authors have studied the stability of different concentrations of melphalan; however, most were not adapted to the current manufacturing process applied in pharmaceutical centralized units. This study was conducted to determine the stability of melphalan in 0.9% sodium chloride solutions at concentrations used for intravenous injection in practice. Melphalan is commonly prepared in diluted solutions ranging from 2 to 4 mg/ml for the treatment of adult patients and at lower concentrations (down to 0.5 mg/ml) for pediatric use. Accordingly, these were the three concentrations chosen for this study. Melphalan concentrations were measured with high-performance thin-layer chromatography (HPTLC). At RT, admixtures prepared at 4 mg/ml were stable for up to 8 h without protection from light; however, at lower concentrations, such as 0.5 and 2 mg/ml, stability did not exceed 2 h. When refrigerated, melphalan was stable for 24 h at 2 mg/ml; however, at 0.5 and 4 mg/ml, the drug was not stable. Melphalan solutions present with limited stability at 0.5, 2, and 4 mg/ml and are not adapted for delayed administration in pharmaceutical centralized units. However, at 4 mg/ml and at RT, a stability of 8 h is very interesting in practice and allows sufficient time for preparation, pharmaceutical control, transport, and administration.
NASA Astrophysics Data System (ADS)
Stammeier, Jessica; Hippler, Dorothee; Mavromatis, Vasileios; Sacher, Stephan; Dietzel, Martin
2016-04-01
Amorphous calcium phosphate (Ca3(PO4)2*nH2O; ACP) is often a precursor phase of the mineral (hydroxy-) apatite (Ca5(PO4)3(OH)) that can be formed in natural settings during both authigenic and biogenic mineral formation. Particularly, in the biomineralization process of fish tissue, ACP has shown to be an important transient phase. In solution ACP rapidly transforms into the crystalline phase. The transformation rate highly depends on the physico-chemical conditions of the solution: Ca & P availability, pH and temperature. In natural settings Ca can be provided by different sources: from (1) seawater, (2) porewater, or (3) diagenetically-altered carbonates, whereas local supersaturation of P can be induced by microbial activity. In this study, we performed phosphate precipitation experiments in order to monitor the transformation process of the ACP to crystalline hydroxyapatite (HAP) using in-situ Raman spectroscopy. During the experiments the temperature was kept constant at 20.0 ± 0.01 ° C and pH at 9 ± 0.1. 50 ml of 0.3 CaCl 2H2O was titrated at a rate of 5 ml/min to an equal volume of 0.2 M Na2HPO4. The pH was kept constant by titration of 1 M NaOH. During the experiment samples were taken from the solution and instantly filtered. The obtained solid samples were lyophilized and analyzed with XRD, ATR and SEM. The respective solution samples were analyzed using ion chromatography and ICP OES, coupling the spectroscopic data with detailed solution chemistry data. We observed transformation of ACP to HAP to occur within 14 hours, illustrated in a clear peak shift in Raman spectra from 950 cm-1 to 960 cm-1. The obtained results are discussed in the aspects of distribution of major elements during the formation of phosphates and/or the diagenetic alteration of carbonates to phosphates in geologic settings. Financial support by DFG-FG 736 and NAWI Graz is kindly acknowledged.
Khodadoust, S; Ghaedi, M; Hadjmohammadi, M R
2013-11-15
A new extraction method, based on Dispersive Nano-Solid material-Ultrasound Assisted Micro-Extraction (DNSUAME), was used for the preconcentration of the bendiocarb and promecarb pesticides in the water samples prior to high performance liquid chromatography (HPLC). The properties of NiZnS nanomaterial loaded on activated carbon (NiZnS-AC) are characterized by FT-IR, TEM, and BET. This novel nanomaterial showed great adsorptive ability towards the bendiocarb and promecarb pesticides. The effective variables such as the amount of adsorbent (mg: NiZnS-AC), the pH and ionic strength of sample solution, the vortex and ultrasonic time (min), the ultrasonic temperature (°C), and desorption volume (mL) are investigated by screening 2(7-4) experiments of Plackett-Burman (PB) design. The important variables optimized by using a central composite design (CCD) were combined by a desirability function (DF). At optimum conditions, the method has linear response over 0.0033-10 µg mL(-1) with detection limit between 0.0010 and 0.0015 µg mL(-1) with relative standard deviations (RSDs) less than 5.5% (n=3). The method has been successfully applied for the determination of the bendiocarb and promecarb pesticides in the water samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Abdolhosseini, Sana; Ghiasvand, Ali Reza; Heidari, Nahid
2018-05-14
A stainless steel fiber was made porous and adhesive by platinization and then coated by nanostructured polypyrrole (PPy), using an appropriate electrophoretic deposition (EPD) method. The morphological surface structure and functional groups of the PPy-coated fiber were studied using SEM (Scanning electron microscope) instrument. The prepared fiber was used for comparison of direct immersion (DI) and electroenhanced direct immersion solid-phase microextraction (EE-DI-SPME) of nicotine in human plasma and urine samples followed by gas chromatography flame ionization detector (GC-FID) determination. The effects of the influential experimental parameters on the efficiency of the DI-SPME and EE-DI-SPME methods, including the pH and ionic strength of the sample solution, applied Direct current (DC) voltage, extraction temperature and time and stirring rate, were optimized. Under the optimal conditions, the calibration curves for the DI-SPME-GC-FID and EE-DI-SPME-GC-FID methods were linear over the ranges of 0.1⁻10.0 μg mL -1 and 0.001⁻10.0 μg mL -1 , respectively. The relative standard deviations (RSDs, n = 6) were found to be 6.1% and 4.6% for the DI and EE strategies, respectively. The LODs (limit of detection) of the DI-SPME-GC-FID and EE-DI-SPME-GC-FID methods were found to be 10 and 0.3 ng mL -1 , respectively. The relative recovery values (for the analysis of 1 µg mL -1 nicotine) were found to be 91⁻110% for EE-DI-SPME and 75⁻105% for DI-SPME. The enrichment factors for DI-SPME and EE-DI-SPME sampling were obtained as 38,734 and 50,597, respectively. The results indicated that EE-SPME was more efficient for quantitation of nicotine in biological fluids. The developed procedure was successfully carried out for the extraction and measurement of nicotine in real plasma and urine samples.
Development of microwave assisted spectrophotometric method for the determination of glucose
NASA Astrophysics Data System (ADS)
Ali, Asif; Hussain, Zahid; Arain, Muhammad Balal; Shah, Nasrullah; Khan, Khalid Mohammad; Gulab, Hussain; Zada, Amir
2016-01-01
A spectrophotometric method was developed based on the microwave assisted synthesis of Maillard product. Various conditions of the reaction were optimized by varying the relative concentration of the reagents, operating temperature and volume of solutions used in the reaction in the microwave synthesizer. The absorbance of the microwave synthesized Maillard product was measured in the range of 360-740 nm using UV-Visible spectrophotometer. Based on the maximum absorbance, 370 nm was selected as the optimum wave length for further studies. The LOD and LOQ of glucose was found 3.08 μg mL- 1 and 9.33 μg mL- 1 with standard deviation of ± 0.05. The developed method was also applicable to urine sample.
Toxicological assessment of polyhexamethylene biguanide for water treatment
Mahmood, Abdulai Seidu; Awortwe, Charles; Nyarko, Alexander K.
2015-01-01
Polyhexamethylene biguanide (PHMB) is an antiseptic with antiviral and antibacterial properties used in a variety of products including wound care dressings, contact lens cleaning solutions, perioperative cleansing products, and swimming pool cleaners. There are regulatory concerns with regard to its safety in humans for water treatment. We decided to assess the safety of this chemical in Sprague-Dawley rats. PHMB was administered in a single dose by gavage via a stomach tube as per the manufacturer's instruction within a dose range of 2 mg/kg to 40 mg/kg. Subchronic toxicity studies were also conducted at doses of 2 mg/kg, 8 mg/kg and 32 mg/kg body weight and hematological, biochemical and histopathological findings of the major organs were assessed. Administration of a dose of 25.6 mg/kg, i.e. 1.6 mL of 0.4% PHMB solution (equivalent to 6.4x103 mg/L of 0.1% solution) resulted in 50% mortality. Histopathological analysis in the acute toxicity studies showed that no histopathological lesions were observed in the heart and kidney samples but 30% of the animals had mild hydropic changes in zone 1 of their liver samples, while at a dosage of 32 mg/kg in the subchronic toxicity studies, 50% of the animals showed either mild hepatocyte cytolysis with or without lymphocyte infiltration and feathery degeneration. Lymphocyte infiltration was, for the first time, observed in one heart sample, whereas one kidney sample showed mild tubular damage. The acute studies showed that the median lethal dose (LD50) is 25.6 mg/kg (LC50 of 1.6 mL of 0.4% PHMB. Subchronic toxicological studies also revealed few deleterious effects on the internal organs examined, as seen from the results of the biochemical parameters evaluated. These results have implications for the use of PHMB to make water potable. PMID:27486381
Barua, Suman; Rahman, Ismail M M; Alam, Iftakharul; Miyaguchi, Maho; Sawai, Hikaru; Maki, Teruya; Hasegawa, Hiroshi
2017-08-15
A relatively rapid and precise method is presented for the determination of lead in aqueous matrix. The method consists of analyte quantitation using the liquid electrode plasma-optical emission spectrometry (LEP-OES) coupled with selective separation/preconcentration by solid-phase extraction (SPE). The impact of operating variables on the retention of lead in SPEs such as pH, flow rate of the sample solution; type, volume, flow rate of the eluent; and matrix effects were investigated. Selective SPE-separation/preconcentration minimized the interfering effect due to manganese in solution and limitations in lead-detection in low-concentration samples by LEP-OES. The LEP-OES operating parameters such as the electrical conductivity of sample solution; applied voltage; on-time, off-time, pulse count for applied voltage; number of measurements; and matrix effects have also been optimized to obtain a distinct peak for the lead at λ max =405.8nm. The limit of detection (3σ) and the limit of quantification (10σ) for lead determination using the technique were found as 1.9 and 6.5ng mL -1 , respectively. The precision, as relative standard deviation, was lower than 5% at 0.1μg mL -1 Pb, and the preconcentration factor was found to be 187. The proposed method was applied to the analysis of lead contents in the natural aqueous matrix (recovery rate:>95%). The method accuracy was verified using certified reference material of wastewaters: SPS-WW1 and ERM-CA713. The results from LEP-OES were in good agreement with inductively coupled plasma optical emission spectrometry measurements of the same samples. The application of the method is rapid (≤5min, without preconcentration) with a reliable detection limit at trace levels. Copyright © 2017 Elsevier B.V. All rights reserved.
Ibraheem, J J; Paalzow, L; Tfelt-Hansen, P
1983-01-01
Fifteen migraine patients were administered 2 mg ergotamine tartrate in a partial cross-over design as a single, oral tablet, rectal suppository and rectal solution. Eight of these patients were in a previous investigation given 0.5 mg ergotamine tartrate intravenously. The blood samples were taken up to 54 h after oral and suppository while it was followed for only 3 h after rectal solution. The chemical analysis was performed by applying h.p.l.c. method with a limit of sensitivity of 0.1 ng/ml ergotamine base in plasma. No ergotamine was detected in the blood samples after the oral route, whereas small and very variable quantities was found in blood after the rectal route. Regular calculation of bioavailability could therefore not be performed. An estimate of the maximal possible bioavailability was found to yield a mean value of 2% (tablets); 5% (suppositories) and 6% (rectal solution). Rectal solution elicited faster absorption and the extent of absorption was significantly higher (P less than 0.05) than for the suppository. PMID:6419759
NASA Astrophysics Data System (ADS)
Leite, Clarice C.; de Jesus, Alexandre; Kolling, Leandro; Ferrão, Marco F.; Samios, Dimitrios; Silva, Márcia M.
2018-04-01
This work reports a new method for extraction of Cu, Fe and Pb from Brazilian automotive gasoline and their determination by high-resolution continuous source flame atomic absorption spectrometry (HR-CS FAAS). The method was based on the formation of water-in-oil emulsion by mixing 2.0 mL of extraction solution constituted by 12% (w/v) Triton X-100 and 5% (v/v) HNO3 with 10 mL of sample. After heating at 90 °C for 10 min, two well-defined phases were formed. The bottom phase (approximately 3.5 mL), composed of acidified water and part of the ethanol originally present in the gasoline sample, containing the extracted analytes was analyzed. The surfactant and HNO3 concentrations and the heating temperature employed in the process were optimized by Doehlert design, using a Brazilian gasoline sample spiked with Cu, Fe and Pb (organometallic compounds). The efficiency of extraction was investigated and it ranged from 80 to 89%. The calibration was accomplished by using matrix matching method. For this, the standards were obtained performing the same extraction procedure used for the sample, using emulsions obtained with a gasoline sample free of analytes and the addition of inorganic standards. Limits of detection obtained were 3.0, 5.0 and 14.0 μg L-1 for Cu, Fe and Pb, respectively. These limits were estimated for the original sample taking into account the preconcentration factor obtained. The accuracy of the proposed method was assured by recovery tests spiking the samples with organometallic standards and the obtained values ranged from 98 to 105%. Ten gasoline samples were analyzed and Fe was found in four samples (0.04-0.35 mg L-1) while Cu (0.28 mg L-1) and Pb (0.60 mg L-1) was found in just one sample.
1990-09-26
50 ml. Glycerine R -etch 17 ml. Benzalkonium Chloride 35 ml. Ethanol Kroll - etch 2 ml. Hydrofluoric Acid ( 50 %) 4 ml. Nitric Acid Conc. 100 ml...The amount of work given ( 60 % reduction in area ) in this last step was found to be sufficient to recrystallize all of the alloys within 12 hours at...formed at the center of thedisc with the following solution: 10 gins. Zinc Chloride 5 gms. Aluminum Chloride 300 ml. Methanol 50 ml. N - Butanol A JEOL
Zereen, Fahmida; Yilmaz, Vedat; Arslan, Zikri
2013-01-01
A solid phase preconcentration method has been developed using new chelating resin prepared by immobilization of 4-(2-thiazolylazo) resorcinol (TAR) on Chromosorb 106. The method was optimized for determination of rare earth elements (REEs) in seawater and estuarine water samples by inductively coupled plasma mass spectrometry (ICP-MS). The effects of various experimental parameters, such as load pH, eluent concentration, sample and eluent flow rates were examined to find the optimum operating conditions. The REEs were quantitatively retained from saline solutions on a minicolumn Chromosorb 106-TAR resin at pH 5.0 and then eluted with 1.0 mL of 1% (v/v) HNO3. The resin possesses large sorption capacity for REEs ranging from 81.1 µmol g−1 for Lu and 108 µmol g−1 for Nd. Detection limits (3s) varied between 0.06 ng L−1 for Pr to 0.31 for Ce for preconcentration of 5.0 mL blank solutions (pH 5.0). The relative standard deviation for triplicate measurements was less than 5% at 0.1 µg L−1 level. The method was validated by analysis Nearshore seawater certified reference material (CASS–4). The elemental results were comparable with the values reported in literature. The method was verified by analysis of spiked and unspiked coastal seawater and estuarine water samples. PMID:24000264
Zereen, Fahmida; Yilmaz, Vedat; Arslan, Zikri
2013-09-01
A solid phase preconcentration method has been developed using new chelating resin prepared by immobilization of 4-(2-thiazolylazo) resorcinol (TAR) on Chromosorb 106. The method was optimized for determination of rare earth elements (REEs) in seawater and estuarine water samples by inductively coupled plasma mass spectrometry (ICP-MS). The effects of various experimental parameters, such as load pH, eluent concentration, sample and eluent flow rates were examined to find the optimum operating conditions. The REEs were quantitatively retained from saline solutions on a minicolumn Chromosorb 106-TAR resin at pH 5.0 and then eluted with 1.0 mL of 1% (v/v) HNO 3 . The resin possesses large sorption capacity for REEs ranging from 81.1 µmol g -1 for Lu and 108 µmol g -1 for Nd. Detection limits (3s) varied between 0.06 ng L -1 for Pr to 0.31 for Ce for preconcentration of 5.0 mL blank solutions (pH 5.0). The relative standard deviation for triplicate measurements was less than 5% at 0.1 µg L -1 level. The method was validated by analysis Nearshore seawater certified reference material (CASS-4). The elemental results were comparable with the values reported in literature. The method was verified by analysis of spiked and unspiked coastal seawater and estuarine water samples.
Comparison: Mediation Solutions of WSMOLX and WebML/WebRatio
NASA Astrophysics Data System (ADS)
Zaremba, Maciej; Zaharia, Raluca; Turati, Andrea; Brambilla, Marco; Vitvar, Tomas; Ceri, Stefano
In this chapter we compare the WSMO/WSML/WSMX andWebML/WebRatio approaches to the SWS-Challenge workshop mediation scenario in terms of the utilized underlying technologies and delivered solutions. In the mediation scenario one partner uses Roset-taNet to define its B2B protocol while the other one operates on a proprietary solution. Both teams shown how these partners could be semantically integrated.
21 CFR 522.1850 - Polysulfated glycosaminoglycan.
Code of Federal Regulations, 2012 CFR
2012-04-01
... § 522.1850 Polysulfated glycosaminoglycan. (a) Specifications. (1) Each 1-milliliter (mL) ampule of solution contains 250 milligrams (mg) polysulfated glycosaminoglycan. (2) Each mL of solution packaged in 5... weekly for up to 4 weeks (maximum of 8 injections). [72 FR 56896, Oct. 5, 2007, as amended at 74 FR 67816...
Evaluation of White Bentonite Modified by Acid Attack
NASA Astrophysics Data System (ADS)
Andrade, C. G. Bastos; Fermino, D. M.; Fernandes, M. G.; Valenzuela-Diaz, F. R.
For industrial use, the smectite clays must be cleared of impurities, usually obtained by acid modification, using a high concentration solution of inorganic acid at temperatures under boiling point. In the present paper, a sample of white bentonite from Paraiba, Brazil, was modified by hydrochloric acid under moderate conditions (90°C, reaction times of 1, 6, 12, 18 and 24hours in close reactor, concentration of the aqueous solution of hydrochloric acid 1.5 M, acid solution/clay ratio of 1g/10mL). The purpose of these attacks is to reduce the concentration of impurities with minimal change in the clay minerals structure. The modified samples were characterized by X-ray diffraction (XRD), X-ray fluorescence (XRF), Cation Exchange Capacity (CEC), Stereomicroscopy, Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray Detector (EDS). Thus, this modified bentonite tends to be a good economic and environmental alternative in manufacturing of products with high added value such as cosmetics and polymer/clay nanocomposites.
Compression and flexural strength of bone cement mixed with blood.
Tan, J H; Koh, B Th; Ramruttun, A K; Wang, W
2016-08-01
To assess the compression and flexural strength of bone cement mixed with 0 ml, 1 ml, or 2 ml of blood. High viscosity polymethyl methacrylate (PMMA) loaded with or without gentamicin was used. Blood was collected from total knee arthroplasty patients. In the same operating room, one pack of cement each was mixed with 0 ml (control), 1 ml, or 2 ml of blood for 1 minute during the dough phase. The dough was extruded into cylindrical and rectangular moulds for 20 minutes of setting, and then cured in phosphate buffered saline at 37±1ºC for 7 days. The samples were visually inspected for fractures and areas of weakness, and then scanned using microcomputed tomography. 48 gentamicin-loaded and 59 non-gentamicin-loaded samples mixed with 0 ml (control), 1 ml, or 2 ml of blood were randomised for flexural and compression strength testing; each group had at least 6 samples. In samples loaded with or without gentamicin, the flexural and compressive strength was highest in controls, followed by samples mixed with 1 ml or 2 ml of blood. In samples mixed with 2 ml of blood, the flexural strength fell below the standard of 50 MPa. In samples mixed with 2 ml of blood and all gentamicin-loaded samples, the compressive strength fell below the standard of 70 MPa. Microcomputed tomography revealed areas of voids and pores indicating the presence of laminations and partitions within. The biomechanical strength of PMMA contaminated with blood may decrease. Precautions such as saline lavage, pack drying the bone, change of gloves, and prompt insertion of the implant should be taken to prevent blood from contaminating bone cement.
Chandwani, Manisha; Mittal, Rakesh; Chandak, Shweta; Pimpale, Jitesh
2017-01-01
Background: The purpose of this study was to evaluate the microbial reduction in deciduous molars using Morinda citrifolia juice (MCJ) as irrigating solution. Materials and Methods: This was a randomized comparative study including 60 deciduous molars chosen among the patients belonging to the age group of 6–9 years based on the inclusion or exclusion criteria. The selected teeth were divided randomly into two groups based on irrigation solution used, that was, Group I (1% NaOCl) and Group II (MCJ). The microbial samples were collected both pre- and post-irrigation and were transferred for microbial assay. Paired t-test was used for intragroup analysis of pre- and post-operative mean reduction of bacterial colony forming unit (CFU)/ml, whereas Independent t-test was used to assess the intergroup, pre- and post-operative mean reduction of bacterial CFU/ml. Results: In the intragroup comparison, both of the groups showed statistically significant (P < 0.001) reduction in the mean CFU/ml; however, it did not show statistically significant reduction when intergroup comparison was carried out between the two groups. Both the study materials had clinically revealed decrease in the microbial count postirrigation. Conclusion: Both the irrigants, 1% NaOCl and MCJ, were significantly effective in the reduction of mean CFUs/ml postoperatively. The results of this study have confirmed the antibacterial effectiveness of MCJ in the root canals of deciduous teeth. Considering the low toxicity and antibacterial effectiveness of MCJ, it can be advocated as a root canal irrigant in endodontic treatment of primary teeth. PMID:28928778
NASA Astrophysics Data System (ADS)
Chandran, Mahesh; Lee, S. C.; Shim, Jae-Hyeok
2018-02-01
A disordered configuration of atoms in a multicomponent solid solution presents a computational challenge for first-principles calculations using density functional theory (DFT). The challenge is in identifying the few probable (low energy) configurations from a large configurational space before DFT calculation can be performed. The search for these probable configurations is possible if the configurational energy E({\\boldsymbol{σ }}) can be calculated accurately and rapidly (with a negligibly small computational cost). In this paper, we demonstrate such a possibility by constructing a machine learning (ML) model for E({\\boldsymbol{σ }}) trained with DFT-calculated energies. The feature vector for the ML model is formed by concatenating histograms of pair and triplet (only equilateral triangle) correlation functions, {g}(2)(r) and {g}(3)(r,r,r), respectively. These functions are a quantitative ‘fingerprint’ of the spatial arrangement of atoms, familiar in the field of amorphous materials and liquids. The ML model is used to generate an accurate distribution P(E({\\boldsymbol{σ }})) by rapidly spanning a large number of configurations. The P(E) contains full configurational information of the solid solution and can be selectively sampled to choose a few configurations for targeted DFT calculations. This new framework is employed to estimate (100) interface energy ({σ }{{IE}}) between γ and γ \\prime at 700 °C in Alloy 617, a Ni-based superalloy, with composition reduced to five components. The estimated {σ }{{IE}} ≈ 25.95 mJ m-2 is in good agreement with the value inferred by the precipitation model fit to experimental data. The proposed new ML-based ab initio framework can be applied to calculate the parameters and properties of alloys with any number of components, thus widening the reach of first-principles calculation to realistic compositions of industrially relevant materials and alloys.
9 CFR 113.28 - Detection of mycoplasma contamination.
Code of Federal Regulations, 2011 CFR
2011-01-01
... following: 1 percent tetrazolium chloride (ml) 5.5 1 percent thallium acetate (ml) 25 Penicillin (units) 500... solution 525,000 units of Penicillin. Dispense 10 ml aliquots into 60×15 mm disposable culture dishes or...
9 CFR 113.28 - Detection of mycoplasma contamination.
Code of Federal Regulations, 2013 CFR
2013-01-01
... following: 1 percent tetrazolium chloride (ml) 5.5 1 percent thallium acetate (ml) 25 Penicillin (units) 500... solution 525,000 units of Penicillin. Dispense 10 ml aliquots into 60×15 mm disposable culture dishes or...
9 CFR 113.28 - Detection of mycoplasma contamination.
Code of Federal Regulations, 2012 CFR
2012-01-01
... following: 1 percent tetrazolium chloride (ml) 5.5 1 percent thallium acetate (ml) 25 Penicillin (units) 500... solution 525,000 units of Penicillin. Dispense 10 ml aliquots into 60×15 mm disposable culture dishes or...
9 CFR 113.28 - Detection of mycoplasma contamination.
Code of Federal Regulations, 2014 CFR
2014-01-01
... following: 1 percent tetrazolium chloride (ml) 5.5 1 percent thallium acetate (ml) 25 Penicillin (units) 500... solution 525,000 units of Penicillin. Dispense 10 ml aliquots into 60×15 mm disposable culture dishes or...
Bacteriological quality of drinking water from dispensers (coolers) and possible control measures.
Baumgartner, Andreas; Grand, Marius
2006-12-01
Three water dispensers (coolers) were bacteriologically monitored over a period of 3 months to evaluate their hygienic status. For this purpose, 174 samples of chilled and unchilled water were analyzed for levels of mesophilic aerobic bacteria and the presence of Escherichia coli and enterococci in 100-ml samples, and the presence of Pseudomonas aeruginosa in 10- and 100-ml samples. Additionally, 12 samples from 20-liter plastic bottles of spring water used to supply the coolers and 36 samples of 12 different brands of noncarbonated bottled mineral water were similarly analyzed. Water from the coolers yielded aerobic plate counts of 3 to 5 log CFU/ml with a geometric mean of 3.86 log CFU/ml, whereas water from the 20-liter bottles had a mean aerobic plate count of 3.3 log CFU/ml. Aerobic plate counts for noncarbonated mineral waters were generally lower (13 samples, < 10 CFU/ml; 6 samples, 10 to 10(2) CFU/ml; 13 samples, 10(2) to 10(3) CFU/ml; 3 samples, 10(3) to 10(4) CFU/ ml; 1 sample, 2 x 10(4) CFU/ml). Although occasional professional cleaning of the coolers did not affect the aerobic plate count, P. aeruginosa was successfully eliminated 2 weeks after cleaning, with only one cooler becoming recolonized. Neither E. coli nor enterococci was found in any of the water samples tested. However, P. aeruginosa was identified in three (25%) of twelve 100-ml samples from 20-liter bottles of spring water; a similar frequency of 24.1% was seen for water samples from coolers. Overall, 35 (21.6%) of 162 water samples (10 ml) from coolers also yielded P. aeruginosa, suggesting potential growth of P. aeruginosa in the dispensers. Pulsed-field gel electrophoresis typing and antibiotic susceptibility testing found 19 P. aeruginosa isolates from the coolers and bottles to be identical, indicating that a single strain originated from the bottled water rather than the surroundings of the coolers. Because P. aeruginosa can cause serious nosocomial infections, its spread should be strictly controlled in institutions caring for vulnerable people such as hospitals and nursing homes. Consequently, in keeping with legal requirement for bottled spring and mineral water in Switzerland, it is also advisable that P. aeruginosa be absent in 100-ml samples of cooler water.
Accumulation of deuterium oxide in body fluids after ingestion of D/sub 2/O-labeled beverages
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, J.M.; Lamb, D.R.; Burgess, W.A.
A simple low-cost procedure was developed to compare the temporal profiles of deuterium oxide (D/sub 2/O) accumulation in body fluids after ingestion of D/sub 2/O-labeled solutions. D/sub 2/O concentration was measured in plasma and saliva samples taken at various intervals after ingestion of 20 ml of D/sub 2/O mixed with five solutions differing in carbohydrate and electrolyte concentrations. An infrared spectrometer was used to measure D/sub 2/O in purified samples obtained after a 48-h incubation period during which the water (D/sub 2/O and H/sub 2/O) in the sample was equilibrated with an equal volume of distilled water in a sealedmore » diffusion dish. The procedure yields 100% recoveries of 60-500 ppm D/sub 2/O with an average precision of 5%. When compared with values for distilled water, D/sub 2/O accumulation in serial samples of plasma and saliva was slower for ingested solutions containing 40 and 15% glucose and faster for hypotonic saline and a 6% carbohydrate-electrolyte solution. These differences appear to reflect known differences in gastric emptying and intestinal absorption of these beverages. Therefore, this technique may provide a useful index of the rate of water uptake from ingested beverages into the body fluids.« less
Roane, J E; DeVol, T A
2002-11-01
An extractive scintillating resin was evaluated for the simultaneous separation and detection of actinides in acidic solutions. The transuranic extractive scintillating (TRU-ES) resin is composed of an inert macroporous polystyrene core impregnated with organic fluors (diphenyloxazole and 1,4-bis-(4-methyl-5-phenyl-2-oxazolyl)benzene) and an extractant (octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide in tributyl phosphate). The TRU-ES resin was packed into FEP Teflon tubing to produce a flow cell (0.2-mL free column volume), which is placed into a scintillation detection system to obtain pulse height spectra and time series data during loading and elution of actinides onto/from the resin. The alpha-particle absolute detection efficiencies ranged from 77% to 96.5%, depending on the alpha energy and quench. In addition to the on-line analyses, off-line analyses of the effluent can be conducted using conventional detection methods. The TRU-ES resin was applied to the quantification of a mixed radionuclide solution and two actual waste samples. The on-line characterization of the mixed radionuclide solution was within 10% of the reported activities whereas the agreement with the waste samples was not as good due to sorption onto the sample container walls and the oxidation state of plutonium. Agreement between the on-line and off-line analyses was within 35% of one another for both waste samples.
Choo, K S; Kim, I W; Jung, J K; Suh, Y G; Chung, S J; Lee, M H; Shim, C K
2001-06-01
A simple, reliable HPLC-UV detection method was developed for the simultaneous determination of loxoprofen and its metabolites (i.e. trans- and cis-alcohol metabolites), in human plasma and urine samples. The method involves the addition of a ketoprofen (internal standard) solution in methanol, zinc sulfate solution and acetonitrile to plasma and urine samples, followed by centrifugation. An aliquot of the supernatant was evaporated to dryness, and the residue reconstituted in a mobile phase (acetonitrile:water=35:65 v/v, pH 3.0). An aliquot of the solution was then directly injected into the HPLC system. Separations were performed on octadecylsilica column (250x4.5 mm, 5 microm) with a guard column (3.2x1.5 cm, 7 microm) at ambient temperature. Loxoprofen and the metabolites in the eluent were monitored at 220 nm (a.u.f.s. 0.005). Coefficients of variations (CV%) and recoveries for loxoprofen and its metabolites were below 10 and over 96%, respectively, in the 200 approximately 15000 ng ml(-1) range for plasma and 500 approximately 50000 ng ml(-1) range for urine. Calibration curves for all the compounds in the plasma and urine were linear over the above-mentioned concentration ranges with a common correlation coefficient of 0.999. The detection limit of the present method was 100 ng for all the compounds. These results indicate that the present method is very simple and readily applicable to routine bioavailability studies of these compounds with an acceptable sensitivity.
Development of a screening method for the determination of forty-nine priority pollutants in soil
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiang, P.H.T.
1985-01-01
An extraction procedure followed by capillary GC-MS analysis was used to determine soil pollutants. Dual pH solutions with methylene chloride were used as extraction solvent system. Both base/neutral and acidic fractions were analyzed on the same fused silica 30 meter SPB-1 (SE-30) column. A GC-FID with a 60 meter wide-bore SPB-1 glass capillary column was used for quantitative analysis due to its larger sample capacity and higher sensitivity. The precision and accuracy for 5.1 ppm (51 ..mu..g/10 g) concentration in zero soil was less than 25% RSD. A headspace technique was also developed for the determination of volatile compounds. Themore » same instrumental conditions and columns were used as in the extraction procedure. The precision and accuracy for 3 grams soil sample spiked with 5.1 ppm (52 ..mu..g/10 mL) pollutant mixture in a 20 mL vial was less than 3% RSD.« less
Labat, L; Dehon, B; Lhermitte, M
2003-05-01
An inductively coupled plasma mass spectrometer (ICP-MS) with a rapid sample-preparative procedure was used for the determination of selenium in blood serum. Blood serum was prepared by dilution in an acidic solution consisting of nitric acid (1%), X-triton (0.1%) and 1-butanol (0.8%). A calibration curve was established for 1-40 microg mL(-1) (r(2)>0.99). The limit of detection was 0.5 microg mL(-1). Repeatability and intermediate precision were satisfactory with relative standard deviations (RSD) of 2.0% and 3.2%, respectively. This method was easily applied to reference materials with satisfactory accuracy. Good correlation (r(2)=0.96) was observed between ICP-MS and atomic absorption spectrometry (AAS) for the determination of (82)Se in blood serum from 23 patients. These results suggest that the sample preparative procedure coupled with ICP-MS can be used for the routine determination of (82)Se in human blood serum.
Djozan, Djavanshir; Farajzadeh, Mir Ali; Sorouraddin, Saeed Mohammad; Baheri, Tahmineh
2012-07-27
In this study, a developed technique was reported for extraction and pre-concentration of methamphetamine (MAMP) and 3,4-methylenedioxymethamphetamine (MDMA, ecstasy) from urine samples using molecularly imprinted-solid phase extraction (MISPE) along with simultaneous derivatization and dispersive liquid-liquid microextraction (DLLME). Molecularly imprinted microspheres as sorbent in solid phase extraction (SPE) procedure were synthesized using precipitation polymerization with MAMP as the template. Aqueous solution of the target analytes was passed through MAMP-MIP cartridge and the adsorbed analytes were then eluted with methanol. The collected eluate was mixed with butylchloroformate which served as the derivatization reagent as well as the extraction solvent. The mixture was immediately injected into deionized water. After centrifugation, 1 μL of the settled organic phase was injected into gas chromatography-flame ionization detection (GC-FID) or gas chromatography-mass spectrometry (GC-MS). Various experimental parameters affecting the performance of both of the steps (MISPE and DLLME) were thoroughly investigated. The calibration graphs were linear in the ranges of 10-1500 ng mL(-1) (MAMP) and 50-1500 ng mL(-1) (MDMA), and the detection limits (LODs) were 2 and 18 ng mL(-1), respectively. The relative standard deviations (%RSDs) obtained for six repeated experiments (100 ng mL(-1) of each drug) were 5.1% and 6.8% for MAMP and MDMA, respectively. The relative recoveries obtained for the analytes in human urine samples, spiked with different levels of each drug, were within the range of 80-88%. Copyright © 2012 Elsevier B.V. All rights reserved.
Fukuda, Masamichi; Inoue, Amane; Sasaki, Kazuyuki; Takahashi, Nobuo
2004-01-01
Pharmacokinetic studies of antibacterial agents for infectious eye diseases have usually been performed on normal rabbit eyes. In this study, the intraocular penetration of fluoroquinolone ophthalmic solutions was determined in normal rabbit eyes and in rabbit eyes that had the corneal epithelium intentionally removed. We determined the intraocular penetration of ofloxacin (OFLX), levofloxacin (LVFX), and norfloxacin (NFLX), fluoroquinolone ophthalmic solutions that are already on the market and undergoing clinical studies, by injecting 50 microl of each solution into the cul-de-sacs of rabbit eyes three times at 15-min intervals. The drug concentration at 10, 30, 60, 120, and 240 min after final instillation was determined by high-performance liquid chromatography. The maximum concentration in the aqueous humor of normal rabbit eyes was 2.09 +/- 1.56 microg/ml (60 min, OFLX), 2.57 +/- 1.00 microg/ml (30 min, LVFX), and 0.42 +/- 0.12 microg/ml (120 min, NFLX). The drug concentration in the aqueous humor of eyes with intentionally removed corneal epithelium was 12.50 +/- 5.62 microg/ml (30 min, OFLX), 9.02 +/- 2.45 microg/ml (60 min, LVFX), and 8.54 +/- 5.17 microg/ml (30 min, NFLX). The drug penetration of the eye drops into eyes with removed corneal epithelium was around 6 times (OFLX), 3.5 times (LVFX), and 20 times (NFLX) higher than the penetration into the eye with normal cornea. Among the pharmacokinetic parameters of the three ophthalmic solutions according to the one-compartment model, the maximum concentration in the aqueous and the area under the concentration-time curve in the aqueous tended to be higher in the eyes with intentionally removed corneal epithelia than in those with normal corneas.
Pharmacokinetic disposition of 14C-glyburide in patients with varying renal function
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pearson, J.G.; Antal, E.J.; Raehl, C.L.
1986-03-01
The pharmacokinetics of 14C-labeled glyburide were studied in 13 men with varying degrees of renal impairment. Patients received a single, 5 mg oral dose of glyburide as a solution (10 microCi/ml/mg) after a high-carbohydrate breakfast. Serial plasma and breath samples were collected for 48 hours and urine and feces were collected for 5 to 7 days. Patients with normal to moderately impaired renal function (creatinine clearance (CLCR) of 29 to 131 ml/min/1.7 m2) had glyburide plasma t1/2 values of 2.0 to 5.0 hours, with no relationship between CLCR and glyburide clearance. One subject with severe renal impairment (CLCR = 5more » ml/min/1.7 m2) had decreased glyburide clearance that resulted in a t1/2 of 11 hours. The elimination of metabolites was more dependent on renal status but was only significantly affected in the patient with severe renal impairment.« less
27 CFR 21.101 - tert-Butyl alcohol.
Code of Federal Regulations, 2013 CFR
2013-04-01
... needle). Above 20 °C. (f) Identification test. Place five drops of a solution containing approximately 0... (dissolve 5 grams of red mercuric oxide in 20 ml of concentrated sulfuric acid; add this solution to 80 ml of distilled water, and filter when cool). Heat the mixture just to the boiling point and remove from...
27 CFR 21.101 - tert-Butyl alcohol.
Code of Federal Regulations, 2014 CFR
2014-04-01
... needle). Above 20 °C. (f) Identification test. Place five drops of a solution containing approximately 0... (dissolve 5 grams of red mercuric oxide in 20 ml of concentrated sulfuric acid; add this solution to 80 ml of distilled water, and filter when cool). Heat the mixture just to the boiling point and remove from...
27 CFR 21.101 - tert-Butyl alcohol.
Code of Federal Regulations, 2012 CFR
2012-04-01
... needle). Above 20 °C. (f) Identification test. Place five drops of a solution containing approximately 0... (dissolve 5 grams of red mercuric oxide in 20 ml of concentrated sulfuric acid; add this solution to 80 ml of distilled water, and filter when cool). Heat the mixture just to the boiling point and remove from...
Raghavan, R; Burchett, M; Loffredo, D; Mulligan, J A
2000-04-01
A high-performance liquid chromatographic (HPLC) method is described for the determination of residual levels of cisplatin from extracts of surfaces with very low surface area; from extracts of surfaces of coupons made of Teflon (polytetrafluoroethylene, PTFE), stainless steel, and glass; and in aqueous solution collected after rinsing equipment and parts. Initially, the method was developed to determine cisplatin at concentrations ranging from 20 to 200 ng/ml by direct injection. Retaining the same method conditions, the scope of the method was expanded by the addition of a sample preconcentration step, allowing analyses at levels ranging from 0.5 ng to 20 ng/ml. Preconcentration is necessary for the determination of cisplatin in rinse waters at a quantifiable concentration of about 2 PPB. Under these conditions, the detection limit is about 0.2 to 0.3 ng/ml. Residual cisplatin on different types of surfaces, including surfaces with very low surface area, can be determined by swabbing each test surface with a derivatizing solution. The cisplatin recovered in the swabbing solution can be analyzed by HPLC using direct injection or preconcentration, depending on the expected level of cisplatin in the sample. Initial methods were developed to quantitate at a cisplatin concentration of about 100 PPB or higher in solution extracted from surfaces. However, when surface areas are limited because of the size of the parts, solution concentration becomes very low as a result of the minimum volume required for extraction. To support the application of swabbing techniques to surface analysis, stainless steel, Teflon, and glass surfaces were spiked with cisplatin at 2.5 to 20 ng/cm2. Satisfactory overall recoveries of 90% +/- 10% were obtained from all surfaces. Cisplatin has no ultraviolet/visible (UV/Vis) spectral-active functional group that can be used to detect low levels of cisplatin. Hence, diethyldithiocarbamate (DDTC) was used as a derivatizing agent to increase sensitivity to UV absorption at 340 nm. Diethyldithiocarbamate forms complexes with the platinum in cisplatin to yield a platinum-DDTC (Pt-DDTC) complex with a high molar-extinction coefficient. The Pt(DDTC)2 complex thus formed was chromatographically separated and the quantitated by comparison of its detector response to that of a similarly derivatized standard preparation. DDTC also has application as a cleaning agent for cisplatin (e.g., for production equipment cleaning, spill cleanup). Destruction of cisplatin can be affected by the reaction of cisplatin with this cleaning agent. Derivatization of cisplatin will convert active cisplatin to platinum-DDTC on surfaces or in solution. Final cleaning can be accomplished using a water-for-injection rinse. After such a cleaning process, the rinse water, when collected and analyzed, showed levels of free cisplatin less than the detection concentration of 0.2 PPB and a total platinum concentration less than 10 PPB as Pt-DDTC complex.
Pulp tissue dissolution capacity of QMix 2in1 irrigation solution.
Arslan, Dilara; Guneser, Mehmet Burak; Kustarci, Alper; Er, Kursat; Siso, Seyda Herguner
2015-01-01
The aim of this study was to evaluate the tissue dissolution efficacy of four root canal irrigation solutions (sodium hypochlorite [NaOCl], chlorhexidine gluconate [CHX], Octenidine [OCT], and QMix 2in1) on bovine pulp tissue. Fifty bovine pulp tissue samples, each weighing 6.55 mg, were prepared and randomly divided into four experimental groups and one control group (n = 10) according to the dissolution irrigants used: (1) 5.25% NaOCl group; (2) 2% CHX group; (3) OCT group; (4) QMix 2in1 group; and (5) control group (saline solution). These samples were then placed into special bovine dentin reservoir models and immersed for 1 h with each test solution (0.1 mL of each) at room temperature. The pulp samples were then blotted dry and weighed again. The percentage of weight loss was calculated. Statistically analyzed with one-way analysis of variance and post-hoc Tukey tests (P = 0.05). Saline solution did not dissolve the bovine pulp tissue. All groups, except OCT, dissolved pulp samples more effectively than the control group (P < 0.05). The highest tissue dissolution was observed in 5.25% NaOCl group (P < 0.05). No statistically significant difference was found between the tissue-dissolving effect between QMix 2in1 and those of 2% CHX. Within the limitations of this in vitro study, NaOCl exhibited the best tissue-dissolving effect out of all solutions tested. CHX and QMix 2in1 were able to dissolve pulp tissue but less than NaOCl. OCT and saline solutions could not exhibit significantly tissue-dissolving effectiveness. This study shown that QMix 2in1 has little capacity to dissolve pulp tissue therefore used alone is not sufficient for this purpose.
Pulp tissue dissolution capacity of QMix 2in1 irrigation solution
Arslan, Dilara; Guneser, Mehmet Burak; Kustarci, Alper; Er, Kursat; Siso, Seyda Herguner
2015-01-01
Objective: The aim of this study was to evaluate the tissue dissolution efficacy of four root canal irrigation solutions (sodium hypochlorite [NaOCl], chlorhexidine gluconate [CHX], Octenidine [OCT], and QMix 2in1) on bovine pulp tissue. Materials and Methods: Fifty bovine pulp tissue samples, each weighing 6.55 mg, were prepared and randomly divided into four experimental groups and one control group (n = 10) according to the dissolution irrigants used: (1) 5.25% NaOCl group; (2) 2% CHX group; (3) OCT group; (4) QMix 2in1 group; and (5) control group (saline solution). These samples were then placed into special bovine dentin reservoir models and immersed for 1 h with each test solution (0.1 mL of each) at room temperature. The pulp samples were then blotted dry and weighed again. The percentage of weight loss was calculated. Statistically analyzed with one-way analysis of variance and post-hoc Tukey tests (P = 0.05). Results: Saline solution did not dissolve the bovine pulp tissue. All groups, except OCT, dissolved pulp samples more effectively than the control group (P < 0.05). The highest tissue dissolution was observed in 5.25% NaOCl group (P < 0.05). No statistically significant difference was found between the tissue-dissolving effect between QMix 2in1 and those of 2% CHX. Conclusions: Within the limitations of this in vitro study, NaOCl exhibited the best tissue-dissolving effect out of all solutions tested. CHX and QMix 2in1 were able to dissolve pulp tissue but less than NaOCl. OCT and saline solutions could not exhibit significantly tissue-dissolving effectiveness. This study shown that QMix 2in1 has little capacity to dissolve pulp tissue therefore used alone is not sufficient for this purpose. PMID:26430374
Effect of graphite oxide solution concentration on the properties of multilayer graphene
DOE Office of Scientific and Technical Information (OSTI.GOV)
Umar, Marjoni Imamora Ali; Yap, Chi Chin; Awang, Rozidawati
2013-11-27
This paper reports the influence of graphite oxide (GO) solution concentration on the optical and electrical properties of multilayer graphene (MLG) films. Graphene oxide (GrO) films were deposited on the glass substrates by spin coating aqueous solutions of GO with different concentrations (7, 8, 9, 10 and 11 mg/ml). The GrO films were then thermally reduced at temperature of 500°C in argon flow for half an hour to form MLG films. Both the transmittance and sheet resistance decreased with the GO concentration from 8 mg/ml to 9 mg/ml, possibly due to thicker and uniform coverage of MLG over the substrate.more » However, the transmittance and sheet resistance increased rapidly as the GO concentration reached 11 mg/ml, which can be attributed to poor film quality. The MLG film obtained at concentration of 10 mg/ml showed the highest transmittance/sheet resistance ratio with 69 % transmittance and sheet resistance of 292 ± 63 kΩ/sq. The optimum MLG film was utilized as counter electrode in dye sensitized solar cells based on ZnO nanorods.« less
Electronic cigarette solutions and resultant aerosol profiles.
Herrington, Jason S; Myers, Colton
2015-10-30
Electronic cigarettes (e-cigarettes) are growing in popularity exponentially. Despite their ever-growing acceptance, their aerosol has not been fully characterized. The current study focused on evaluating e-cigarette solutions and their resultant aerosol for potential differences. A simple sampling device was developed to draw e-cigarette aerosol into a multi-sorbent thermal desorption (TD) tube, which was then thermally extracted and analyzed via a gas chromatography (GC) mass spectrometry (GC-MS) method. This novel application provided detectable levels of over one hundred fifteen volatile organic compounds (VOCs) and semivolatile organic compounds (SVOCs) from a single 40mL puff. The aerosol profiles from four commercially available e-cigarettes were compared to their respective solution profiles with the same GC-MS method. Solution profiles produced upwards of sixty four unidentified and identified (some only tentatively) constituents and aerosol profiles produced upwards of eighty two compounds. Results demonstrated distinct analyte profiles between liquid and aerosol samples. Most notably, formaldehyde, acetaldehyde, acrolein, and siloxanes were found in the aerosol profiles; however, these compounds were never present in the solutions. These results implicate the aerosolization process in the formation of compounds not found in solutions; have potential implications for human health; and stress the need for an emphasis on electronic cigarette aerosol testing. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.
Muniraj, Sarangapani; Yan, Cheing-Tong; Shih, Hou-Kung; Ponnusamy, Vinoth Kumar; Jen, Jen-Fon
2012-11-19
A new simultaneous derivatization and extraction method for the preconcentration of ammonia using new one-step headspace dynamic in-syringe liquid-phase microextraction with in situ derivatization was developed for the trace determination of ammonium in aqueous samples by liquid chromatography with fluorescence detection (LC-FLD). The acceptor phase (as derivatization reagent) containing o-phthaldehyde and sodium sulfite was held within a syringe barrel and immersed in the headspace of sample container. The gaseous ammonia from the alkalized aqueous sample formed a stable isoindole derivative with the acceptor phase inside the syringe barrel through the reciprocated movements of plunger. After derivatization-cum-extraction, the acceptor phase was directly injected into LC-FLD for analysis. Parameters affecting the ammonia evolution and the extraction/derivatization efficiency such as sample matrix, pH, temperature, sampling time, and the composition of derivatization reagent, reaction temperature, and frequency of reciprocated plunger, were studied thoroughly. Results indicated that the maximum extraction efficiency was obtained by using 100μL derivatization reagent in a 1-mL gastight syringe under 8 reciprocated movements of plunger per min to extract ammonia evolved from a 20mL alkalized aqueous solution at 70°C (preheated 4min) with 380rpm stirring for 8min. The detection was linear in the concentration range of 0.625-10μM with the correlation coefficient of 0.9967 and detection limit of 0.33μM (5.6ng mL(-1)) based on SN(-1)=3. The method was applied successfully to determine ammonium in real water samples without any prior cleanup of the samples, and has been proved to be a simple, sensitive, efficient and cost-effective procedure for trace ammonium determination in aqueous samples. Copyright © 2012 Elsevier B.V. All rights reserved.
Vidal, Juan C; Bonel, Laura; Ezquerra, Alba; Duato, Patricia; Castillo, Juan R
2012-06-01
We report a direct competitive immunosensor for the rapid determination of ochratoxin A (OTA) in wine samples. Magnetic beads (1 ± 0.5 μm diameter) covered with streptavidin were functionalized with a monoclonal antibody against OTA, and then left to incubate in a solution of tracer (ochratoxin conjugated to the enzyme peroxidase) and a range of OTA concentrations (10(-4) to 1,000 ng mL(-1)). After washing and separation steps helped with a magnetic field, a volume of the dispersion was put on screen-printed electrodes under a magnet, and after adding the substrate the p-benzoquinone generated enzymatically was detected by differential-pulse voltammetry. Wine samples (2 mL) were easily prepared simply by adjusting to pH = 7.5 with diluted NaOH and by adding polyvinylpyrrolidone for complexing polyphenols, without any other clean-up or preconcentration steps. The limit of detection for detecting OTA in wines was of 0.11 ± 0.01 ng L(-1), well below the permitted content of the mycotoxin by the European Union (<2 ng mL(-1)). Spiked wines were subjected to immunosensor calibrations to study the matrix effects. OTA concentrations measured with the immunosensor were compared with those obtained by high-performance liquid chromatography coupled to fluorescence detection (AOAC official method 2001.01). The OTA levels from two red wines of "Campo de Borja", Spain, ranged from about 0.027 to 0.033 ng mL(-1) of OTA.
NASA Astrophysics Data System (ADS)
Salem, A. A.; Barsoum, B. N.; Izake, E. L.
2004-03-01
New spectrophotometric and fluorimetric methods have been developed to determine diazepam, bromazepam and clonazepam (1,4-benzodiazepines) in pure forms, pharmaceutical preparations and biological fluid. The new methods are based on measuring absorption or emission spectra in methanolic potassium hydroxide solution. Fluorimetric methods have proved selective with low detection limits, whereas photometric methods showed relatively high detection limits. Successive applications of developed methods for drugs determination in pharmaceutical preparations and urine samples were performed. Photometric methods gave linear calibration graphs in the ranges of 2.85-28.5, 0.316-3.16, and 0.316-3.16 μg ml -1 with detection limits of 1.27, 0.08 and 0.13 μg ml -1 for diazepam, bromazepam and clonazepam, respectively. Corresponding average errors of 2.60, 5.26 and 3.93 and relative standard deviations (R.S.D.s) of 2.79, 2.12 and 2.83, respectively, were obtained. Fluorimetric methods gave linear calibration graphs in the ranges of 0.03-0.34, 0.03-0.32 and 0.03-0.38 μg ml -1 with detection limits of 7.13, 5.67 and 16.47 ng ml -1 for diazepam, bromazepam and clonazepam, respectively. Corresponding average errors of 0.29, 4.33 and 5.42 and R.S.D.s of 1.27, 1.96 and 1.14 were obtained, respectively. Statistical Students t-test and F-test have been used and satisfactory results were obtained.
O'Bichere, Austin; Green, Colin; Phillips, Robin K S
2004-09-01
Water for colostomy irrigation is largely absorbed by the colon, which may result in less efficient expulsion of stool. This study compared the outcome of colonic cleansing with water and polyethylene glycol solution. In a cross-over study, 41 colostomy irrigators were randomly assigned to water or polyethylene glycol solution irrigation first and then the other regimen, each for one week. Patients recorded fluid inflow time, total washout time, cramps, leakage episodes, number of stoma pouches used, and satisfaction scores (Visual Analog Scale, 1-10: 1 = poor, and 10 = excellent). The median and interquartile range for each variable was calculated, and the two treatments were compared (Wilcoxon's test). Eight patients failed to complete the study. Thirty-three patients (20 females; mean age, 55 (range, 39-73) years) provided 352 irrigation sessions: water (n = 176), and polyethylene glycol solution (n = 176). Irrigation was performed every 24, 48, and 72 hours by 17, 9, and 7 patients respectively, using 500 ml (n = 1), 750 ml (n = 2), 1,000 ml (n = 16), 1,500 ml (n = 11), 2,000 ml (n = 2), and 3,500 ml (n = 1) of fluid. The median and interquartile range for water vs. polyethylene glycol solution were: fluid inflow time (6 (range, 4.4-10.8) vs. 6.3 (range, 4.1-11) minutes; P = 0.48), total washout time (53 (range, 33-69) vs. 38 (range, 28-55) minutes; P = 0.01), leakage episodes (2.3 (range, 1.7-3.8) vs. 0.7 (range, 0.2-1); P < 0.001), satisfaction score (5.8 (range, 4-7.5) vs. 8.8 (range, 8.3-10); P < 0.001), and stoma pouch usage per week (75 (range, 45-80) vs. 43 (range, 0-80); P = 0.008). No difference was demonstrated for frequency of cramps ( P = 0.24). Polyethylene glycol solution performed significantly better than water and may be a superior alternative fluid regimen for colostomy irrigation.
A new solid-phase extraction disk based on a sheet of single-walled carbon nanotubes.
Niu, Hong Yun; Cai, Ya Qi; Shi, Ya Li; Wei, Fu Sheng; Liu, Jie Min; Jiang, Gui Bin
2008-11-01
A new kind of solid-phase extraction disk based on a sheet of single-walled carbon nanotubes (SWCNTs) is developed in this study. The properties of such disks are tested, and different disks showed satisfactory reproducibility. One liter of aqueous solution can pass through the disk within 10-100 min while still allowing good recoveries. Two disks (DD-disk) can be stacked to enrich phthalate esters, bisphenol A (BPA), 4-n-nonylphenol (4-NP), 4-tert-octylphenol (4-OP) and chlorophenols from various volumes of solution. The results show that SWCNT disks have high extraction ability for all analytes. The SWCNT disk can extract polar chlorophenols more efficiently than a C(18) disk from water solution. Unlike the activated carbon disk, analytes adsorbed by the new disks can be eluted completely with 8-15 mL of methanol or acetonitrile. Finally, the DD-disk system is used to pretreat 1000-mL real-world water samples spiked with BPA, 4-OP and 4-NP. Detection limits of 7, 25, and 38 ng L(-1) for BPA, 4-OP, and 4-NP, respectively, were achieved under optimized conditions. The advantages of this new disk include its strong adsorption ability, its high flow rate and its easy preparation.
Sharaf, Maged H M; Stiff, Dwight D
2004-06-29
A method for the quantitation of guaifenesin in human serum has been developed and validated. The procedure involves liquid-liquid extraction of the serum sample in the presence of mephenesin as an internal standard, followed by derivatization and analysis using capillary gas chromatography (GC) and electron capture detection (ECD). Different solvents were tested for extraction of guaifenesin from serum. n-Hexane/dichloromethane (1:1, v/v) gave the highest recovery and the lowest background and was chosen as the extraction solvent. After extraction, the residue of guaifenesin was derivatized at 60 degrees C for 30 min, with trifluoroacetic acid anhydride (TFAA) in toluene in the presence of pyridine. Excess trifluoroacetic acid anhydride was removed using dilute solution of ammonium hydroxide. The method proved to be linear over the range of 25.0-1000 ng/ml. Recovery of guaifenesin from spiked samples was consistent, averaging 75.5% at 50.0 ng/ml with a range of 72.0-80.0% (N = 8 determinations) and averaging 78% at 800 ng/ml with a range of 76.0-81.0% (N = 8 determinations). The internal standard recovery was also consistent averaging 72.8% with a range of 67.0-76.0% (N = 16 determinations). Copyright 2004 Elsevier B.V.
Mahpishanian, Shokouh; Sereshti, Hassan
2014-12-01
Graphene oxide (GO) has showed great potential to use as an adsorbent in sample preparation procedures. In this research, GO was used as an effective adsorbent in a simple GO-based dispersive micro-solid phase extraction (GO-D-µ-SPE) method for isolation and preconcentration of nicotine prior to gas chromatography-flame ionization detection (GC-FID). The prepared GO was characterized by X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy, scanning electron microscope (SEM), thermogravimetric analysis/differential thermal analysis (TGA/DTA), and ultraviolet-visible (UV-vis) absorption spectroscopy techniques. Various experimental parameters affecting the extraction recovery, including the amount of GO, extraction time, pH of the sample solution, salt concentration, and desorption conditions were investigated and optimized. Under the optimized conditions, a linear response was obtained in the concentration range of 5-2000 ng mL(-1) with a determination coefficient of 0.9987. The limit of detection (LOD) of the method at a signal to noise ratio of 3 was 1.5 ng mL(-1). The linearity was in the concentration range of 5-2000 ng mL(-1) with a determination coefficient of 0.9987. Intraday and inter-day precisions were obtained equal to 2.7% and 5.2%, respectively. The method was successfully applied to the nicotine analysis in biological and water samples with the recoveries in the range of 88.7-109.7%. Copyright © 2014 Elsevier B.V. All rights reserved.
Limonene encapsulation in freeze dried gellan systems.
Evageliou, Vasiliki; Saliari, Dimitra
2017-05-15
The encapsulation of limonene in freeze-dried gellan systems was investigated. Surface and encapsulated limonene content was determined by measurement of the absorbance at 252nm. Gellan matrices were both gels and solutions. For a standard gellan concentration (0.5wt%) gelation was induced by potassium or calcium chloride. Furthermore, gellan solutions of varying concentrations (0.25-1wt%) were also studied. Limonene was added at two different concentrations (1 and 2mL/100g sample). Gellan gels encapsulated greater amounts of limonene than solutions. Among all gellan gels, the KCl gels had the greater encapsulated limonene content. However, when the concentration of limonene was doubled in these KCl gels, the encapsulated limonene decreased. The surface limonene content was significant, especially for gellan solutions. The experimental conditions and not the mechanical properties of the matrices were the dominant factor in the interpretation of the observed results. Copyright © 2016 Elsevier Ltd. All rights reserved.
Elizalde-González, María P; Mattusch, J; Wennrich, R
2008-07-01
The surface chemistry of maize naturasorbent was altered in this work by the modifying agents: phosphoric acid and different amines (triethanolamine, diethylenetriamine and 1,4-diaminobutane). Removal of methyl orange (25 mg l(-1)) was <50% by maize corn cobs modified by phosphorylation and higher by the quaternized samples: 68% with the 1,4-diaminobutane and 73% with the diethylenetriamine modificators. Adsorption of arsenite by the samples modified with phosphoric acid/ammonia was 11 microg g(-1), which corresponds to 98% removal from a 550 microg As l(-1) solution for an adsorbent dose of 50 mg ml(-1). The samples modified by phosphoric acid/urea removed 0.4 microg g(-1) arsenate from a 300 mug As l(-1) solution. Adsorption of methyl orange, arsenite and arsenate was superior by the chemically modified maize cobs judged against the initial naturasorbent. For comparison, removal by the commercial anion exchanger was 100% for methyl orange, 45% (5 microg g(-1)) for arsenite and 99% (5 microg g(-1)) for arsenate.
Toxin detection using a fiber-optic-based biosensor
NASA Astrophysics Data System (ADS)
Ogert, Robert A.; Shriver-Lake, Lisa C.; Ligler, Frances S.
1993-05-01
Using an evanescent wave fiber optic-based biosensor developed at Naval Research Laboratory, ricin toxin can be detected in the low ng/ml range. Sensitivity was established at 1 - 5 ng/ml using a two-step assay. The two-step assay showed enhanced signal levels in comparison to a one-step assay. A two-step assay utilizes a 10 minute incubation of an immobilized affinity purified anti-ricin antibody fiber optic probe in the ricin sample before placement in a solution of fluorophore-labeled goat anti-ricin antibodies. The specific fluorescent signal is obtained by the binding of the fluorophore-labeled antibodies to ricin which is bound by the immobilized antibodies on the fiber optic probe. The toxin can be detected directly from urine and river water using this fiber optic assay.
Filik, Hayati; Sener, Izzet; Cekiç, Sema Demirci; Kiliç, Emine; Apak, Reşat
2006-06-01
In the present paper, conventional spectrophotometry in conjunction with cloud point extraction-preconcentration were investigated as alternative methods for paracetamol (PCT) assay in urine samples. Cloud point extraction (CPE) was employed for the preconcentration of p-aminophenol (PAP) prior to spectrophotometric determination using the non-ionic surfactant Triton X-114 (TX-114) as an extractant. The developed methods were based on acidic hydrolysis of PCT to PAP, which reacted at room temperature with 25,26,27,28-tetrahydroxycalix[4]arene (CAL4) in the presence of an oxidant (KIO(4)) to form an blue colored product. The PAP-CAL4 blue dye formed was subsequently entrapped in the surfactant micelles of Triton X-114. Cloud point phase separation with the aid of Triton X-114 induced by addition of Na(2)SO(4) solution was performed at room temperature as an advantage over other CPE assays requiring elevated temperatures. The 580 nm-absorbance maximum of the formed product was shifted bathochromically to 590 nm with CPE. The working range of 1.5-12 microg ml(-1) achieved by conventional spectrophotometry was reduced down to 0.14-1.5 microg ml(-1) with cloud point extraction, which was lower than those of most literature flow-through assays that also suffer from nonspecific absorption in the UV region. By preconcentrating 10 ml sample solution, a detection limit as low as 40.0 ng ml(-1) was obtained after a single-step extraction, achieving a preconcentration factor of 10. The stoichiometric composition of the dye was found to be 1 : 4 (PAP : CAL4). The impact of a number of parameters such as concentrations of CAL4, KIO(4), Triton X-100 (TX-100), and TX-114, extraction temperature, time periods for incubation and centrifugation, and sample volume were investigated in detail. The determination of PAP in the presence of paracetamol in micellar systems under these conditions is limited. The established procedures were successfully adopted for the determination of PCT in urine samples. Since the drug is rapidly absorbed and excreted largely in urine and its high doses have been associated with lethal hepatic necrosis and renal failure, development of a rapid, sensitive and selective assay of PCT is of vital importance for fast urinary screening and antidote administration before applying more sophisticated, but costly and laborious hyphenated instrumental techniques of HPLC-SPE-NMR-MS.
Mass spectrometer output file format mzML.
Deutsch, Eric W
2010-01-01
Mass spectrometry is an important technique for analyzing proteins and other biomolecular compounds in biological samples. Each of the vendors of these mass spectrometers uses a different proprietary binary output file format, which has hindered data sharing and the development of open source software for downstream analysis. The solution has been to develop, with the full participation of academic researchers as well as software and hardware vendors, an open XML-based format for encoding mass spectrometer output files, and then to write software to use this format for archiving, sharing, and processing. This chapter presents the various components and information available for this format, mzML. In addition to the XML schema that defines the file structure, a controlled vocabulary provides clear terms and definitions for the spectral metadata, and a semantic validation rules mapping file allows the mzML semantic validator to insure that an mzML document complies with one of several levels of requirements. Complete documentation and example files insure that the format may be uniformly implemented. At the time of release, there already existed several implementations of the format and vendors have committed to supporting the format in their products.
Cheng, Ching-Ling; Lin, E Gin; Chou, Chen-Hsi
2003-08-15
Mitoguazone is an antiproliferative agent used in chemotherapy. This study describes a simple and sensitive high-performance liquid chromatographic method for the determination of mitoguazone in 100 microl of plasma. Samples were deproteinized with 100 microl of a solution of internal standard (amiloride, 10 microg/ml) in acetonitrile. An aliquot of the supernatant was injected onto the column. HPLC separation was achieved on a silica column with the mobile phase of methanol-50 mM potassium phosphate buffer (pH 3)-triethylamine (80:20:0.3, v/v), at a flow-rate of 1 ml/min. The eluent was detected at 320 nm. The retention time was about 5.5 min for amiloride and 12 min for mitoguazone. No endogenous substances were found to interfere. Calibration curves were linear from 0.25 to 50 microg/ml. The absolute recoveries of mitoguazone and amiloride were both greater than 84%. The limit of quantitation was 0.25 microg/ml. The intra- and inter-day precision (expressed as RSD) was 5.8%, or less, and the accuracy was 94.7% of the nominal concentration. The method is suitable in pharmacokinetic investigation and monitoring mitoguazone concentration.
Mechanisms of Action of Anticholinesterases and Oximes on Acetylcholine Receptors
1988-07-23
Maidstone, England) presoaked in 0.05% polyethylenimine (Sigma, St. Louis, MO) solution (to reduce nonspecific binding). The sample was washed on the...fiber filters presoaked in 0.05% polyethylenimine , using a Cell Harvester (Brandel, Gaithersburg, MD). Filters were washed twice with 5 ml of ice-cold...York). Cells were incubated at 370 in an atmosphere consisting of 10% CO2 and 90% humidified air. The medium was changed on day 3 and day 5 and
Improved Detection Technique for Solvent Rinse Cleanliness Verification
NASA Technical Reports Server (NTRS)
Hornung, S. D.; Beeson, H. D.
2001-01-01
The NASA White Sands Test Facility (WSTF) has an ongoing effort to reduce or eliminate usage of cleaning solvents such as CFC-113 and its replacements. These solvents are used in the final clean and cleanliness verification processes for flight and ground support hardware, especially for oxygen systems where organic contaminants can pose an ignition hazard. For the final cleanliness verification in the standard process, the equivalent of one square foot of surface area of parts is rinsed with the solvent, and the final 100 mL of the rinse is captured. The amount of nonvolatile residue (NVR) in the solvent is determined by weight after the evaporation of the solvent. An improved process of sampling this rinse, developed at WSTF, requires evaporation of less than 2 mL of the solvent to make the cleanliness verification. Small amounts of the solvent are evaporated in a clean stainless steel cup, and the cleanliness of the stainless steel cup is measured using a commercially available surface quality monitor. The effectiveness of this new cleanliness verification technique was compared to the accepted NVR sampling procedures. Testing with known contaminants in solution, such as hydraulic fluid, fluorinated lubricants, and cutting and lubricating oils, was performed to establish a correlation between amount in solution and the process response. This report presents the approach and results and discusses the issues in establishing the surface quality monitor-based cleanliness verification.
Albumin adsorption onto surfaces of urine collection and analysis containers☆
Robinson, Mary K.; Caudill, Samuel P.; Koch, David D.; Ritchie, James; Hortin, Glen; Eckfeldt, John H.; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W. Greg
2017-01-01
Background Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. Methods We added 125I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Results Adsorption of urine albumin (UA) at 5–6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH 8 than pH 5 but only 3 cases had p <0.05. Adsorption from 11 unaltered urine samples with albumin 5–333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2 l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2–28%) was larger than that from urine. Conclusions Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. PMID:24513540
Albumin adsorption onto surfaces of urine collection and analysis containers.
Robinson, Mary K; Caudill, Samuel P; Koch, David D; Ritchie, James; Hortin, Glen; Eckfeldt, John H; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W Greg
2014-04-20
Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. We added (125)I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Adsorption of urine albumin (UA) at 5-6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH8 than pH5 but only 3 cases had p<0.05. Adsorption from 11 unaltered urine samples with albumin 5-333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2-28%) was larger than that from urine. Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. Copyright © 2014 Elsevier B.V. All rights reserved.
Shariati, Shahab; Golshekan, Mostafa
2011-06-01
In the present study, a simple and efficient extraction method based on dispersive liquid-liquid microextraction prior to UV-Vis spectrophotometry was developed for the preconcentration and determination of copper ions in environmental samples. Briefly, cupric ions (Cu II) were reduced to cuprous (Cu I) with addition of hydroxyl amine hydrochloride and formed hydrophobic chelates with neocuproine. Then, a proper mixture of acetonitrile (as dispersive solvent) and choloroform (as extraction solvent) was rapidly injected into the solution and a cloudy solution was formed. After centrifuging, choloroform was sedimented at the bottom of a conical tube and diluted with 100 µL of methanol for further UV-Vis spectrophotometry measurement. An orthogonal array design (OAD) was employed to study the effects of different parameters on the extraction efficiency. Under the optimum experimental conditions, a preconcentration factor up to 63.6 was achieved for extraction from 5.0 mL of sample solution. The limit of detection (LOD) based on S/N = 3 was 0.33 µg L-1 and the calibration curve was linear in the range of 1-200 µg L-1 with reasonable linearity (r2 > 0.997). Finally, the accuracy of the proposed method was successfully evaluated by determination of trace amounts of copper ions in different water samples and satisfactory results were obtained.
Serum Antibody Responses to Oral Microorganisms in Nonhuman Primates
1991-05-01
BBL Microbiology Systems, Cockeysville, Md.) with 5% sheep blood and supplemented with 5 g/ml of hemin and 1 ,g/ml of menadione . The stock solutions...of menadione in 50 ml of 95 % ethanol, brought to 100 ml with DH2 0, filter sterilized with a 0.22 jA filter, and stored at 40 C. 20 For antigen...preparation, the organisms were grown in mycoplasma broth base (BBL) supplemented with hemin (5 ug/ml) and menadione (1 ;ig/ml) under anaerobic conditions
2008-07-07
Ibuprofen 800-mg tablet. Because of several negative side effects, Chlorpromazine HCL INJ can be replaced with Haloperidol HCL INJ or Promethazine HCL...CART 10S EA 6505013548591 FLUMAZENIL INJ 0.1MG/ML 10ML VI 10S VI 6505002688530 HALOPERIDOL INJ 5MG/ML 1ML AMPUL 10S AM 6505001538480 HYDROGEN...DIAZEPAM TAB 5MG INDIVIDUALLY SEALED 100S TB 6505013548591 FLUMAZENIL INJ 0.1MG/ML 10ML VI 10S VI 6505002688530 HALOPERIDOL INJ 5MG/ML 1ML AMP 10S AM
Targeting Autophagy in the Tumor Stroma to Eradicate Breast Cancer
2013-09-01
initiated. One potential caveat that has arisen is that fibroblast specific protein (FSP) may be expressed at low levels in late stage PyMT tumor...digestion solution per 5g of tumor tissue) 1.5 mg/ml Collagenase (from 100X stock solution) 125 U/ml Hyaluronidase (from 100X stock solution) MMF media...g. Determine the latency period to the onset of primary tumor formation and metastasis for recipient mice generated in subtask 1f. At selected
DOE Office of Scientific and Technical Information (OSTI.GOV)
Diantoro, Markus, E-mail: m-diantoror@yahoo.com; Fitrianingsih, Rina, E-mail: m-diantoror@yahoo.com; Mufti, Nandang, E-mail: m-diantoror@yahoo.com
Nanosilver is currently one of the most common engineered nanomaterials and is used in many applications that lead to the release of silver nanoparticles and silver ions into aqueous systems. Nanosilver also possesses enhanced antimicrobial activity and bioavailability that may less environmental risk compared with other manufactured nanomaterials. Described in this research are the synthesis of silver nanoparticle produced by chemical reduction from silver nitrate (AgNO{sub 3}) solution. As a reducing agent, Sodium Borohydride (NaBH{sub 4}) was used and mercaptosuccinic Acid (MSA) as stabilizer to prevent the nanoparticle from aglomerating. It was also used two kinds of solvent, they aremore » water and methanol. In typical experiment MSA was dissolve in methanol with a number of variation of molarity i.e. 0,03 M, 0,06 M, 0,12 M, 0,15 M, and the mixture was kept under vigorous stirring in an ice bath. A solution of silver nitrate of 340 mg in 6,792 ml water was added. A freshly prepared aqueous solution of sodium borohydride (756,6 mL in 100 mL of water) was added drop wisely. The solution was kept for half an hour for stirring and were allowed to settle down in methanol. The obtained samples then characterized by means of x-ray diffractometer, and scanning electron microscopy, as well as transmission electron microscopy to obtain their structures of silver nanoparticles, morphology, and sizes. It is shown that diameter of silver nanoparticle sized about 24.3 nm (Ag@MSA 0.03 M), 20.4 nm (Ag@MSA 0.06 M), 16.8 nm (Ag@MSA 0.12 M), 16.9 nm (Ag@MSA 0.15 M) which was calculated by Scherrer formula by taking the FWHM from fitting to Gaussian. The phases and lattice parameter showed that there is no significant change in its volume by increasing molarity of stabilizer. In contrast, the size of particles is decreasing.« less
James, Lewis J; Clayton, David; Evans, Gethin H
2011-02-01
The present study examined the effects of milk protein on rehydration after exercise in the heat, via the comparison of energy- and electrolyte content-matched carbohydrate and carbohydrate-milk protein solutions. Eight male subjects lost 1·9 (SD 0·2) % of their body mass by intermittent exercise in the heat and rehydrated with 150% of their body mass loss with either a 65 g/l carbohydrate solution (trial C) or a 40 g/l carbohydrate, 25 g/l milk protein solution (trial CP). Urine samples were collected before and after exercise and for 4 h after rehydration. Total cumulative urine output after rehydration was greater for trial C (1212 (SD 310) ml) than for trial CP (931 (SD 254) ml) (P < 0·05), and total fluid retention over the study was greater after ingestion of drink CP (55 (SD 12) %) than that after ingestion of drink C (43 (SD 15) %) (P < 0·05). At the end of the study period, whole body net fluid balance (P < 0·05) was less negative for trial CP (-0·26 (SD 0·27) litres) than for trial C (-0·52 (SD 0·30) litres), and although net negative for both the trials, it was only significantly negative after ingestion of drink C (P < 0·05). The results of the present study suggest that when matched for energy density and fat content, as well as for Na and K concentration, and when ingested after exercise-induced dehydration, a carbohydrate-milk protein solution is better retained than a carbohydrate solution. These results suggest that gram-for-gram, milk protein is more effective at augmenting fluid retention than carbohydrate.
Delta14 CO2 Atmospheric Record from Schauinsland, Germany
Levin, Ingeborg [Institut fur Umweltphysik, University of Heidelberg, Heidelberg, Germany; Kromer, Bernd [Institut fur Umweltphysik, University of Heidelberg, Heidelberg, Germany
1997-01-01
All air samples at Schauinsland have been collected from a ventilated intake stack approximately 7m above the ground. Bi-weekly integrated CO2 samples from about 15-20 m3 of air have been continuously collected by dynamic quantitative absorption in carbonate-free sodium hydroxide (NaOH) solution. Air has been pumped through a rotating glass tube filled with a packed bed of Raschig rings (hard glass) to enlarge the surface of the absorbing NaOH solution (200 ml of 4 normal NaOH). The CO2 absorption is quantitative and samples represent mean values of 10 days to 2 weeks. In the laboratory, the samples are extracted from the NaOH solution in a vacuum system by adding hydrochloric or sulfuric acid. 13C analyses of the CO2 are by mass spectrometry and 14C analyses are by high precision proportional counting, after purification of the CO2 sample over charcoal (Schoch et al. 1980, Kromer and Münnich 1992). δ13C values are given relative to the V-PDB standard (Hut 1987) with the overall precision of a single analysis reported to be +/- 0.15 per mil (Levin and Kromer 1997). δ14C data are given relative to the NIST oxalic acid activity corrected for decay (Stuiver and Polach 1977) with the precision of a single δ14C measurement reported to be +/- 3-5 per mil (Levin and Kromer 1997).
Solution of reduced graphene oxide synthesized from coconut shells and its optical properties
NASA Astrophysics Data System (ADS)
Mas'udah, Kusuma Wardhani; Nugraha, I. Made Ananta; Abidin, Saiful; Mufid, Ali; Astuti, Fahmi; Darminto
2016-04-01
Reduced graphene oxide (r-GO)powder has been prepared from coconut shells by carbonization process at 400°C for 3, 4 and 5 hours.Theresulted sample mass was reduced to be 60% relativelycompared to the starting material. The longer heating duration has also led to the rGO with reduced crystalinity according to the X-ray diffractometry data and TEM. The rGO solution was prepared by adding powders of 5, 10 and 15 grams into 50 ml destiled water and then centrifused at 6000 rpm for 30 minutes.The resulted solutions were seen to be varied form clear transparant, light and dark yellow to black. Measurement using particle size analyser shows that the individual rGO particles tends to be agglomerating each others to form bigger size clustering, manifested by the observed bigger size particles for the increasing amount of soluted rGO powders in water.The varying UV-visible spectra of these rGO solutions together with their optical bandgaps will also be discussed in this study.
A Laboratory Study on the Phase Transition for Polar Stratospheric Cloud Particles
NASA Technical Reports Server (NTRS)
Teets, Edward H., Jr.
1997-01-01
The nucleation and growth of different phases of simulated polar stratospheric cloud (PSC) particles were investigated in the laboratory. Solutions and mixtures of solutions at concentrations 1 to 5 m (molality) of ammonium sulfate, ammonium bisulfate, sodium chloride, sulfuric acid, and nitric acid were supercooled to prescribed temperatures below their equilibrium melting point. These solutions were contained in small diameter glass tubing of volumes ranging from 2.6 to 0.04 ml. Samples were nucleated by insertion of an ice crystal, or in some cases by a liquid nitrogen cooled wire. Crystallization velocities were determined by timing the crystal growth front passages along the glass tubing. Solution mixtures containing aircraft exhaust (soot) were also examined. Crystallization rates increased as deltaT2, where deltaT is the supercooling for weak solutions (2 m or less). The higher concentrated solutions (greater than 3 m) showed rates significantly less than deltaT2. This reduced rate suggested an onset of a glass phase. Results were applied to the nucleation of highly concentrated solutions at various stages of polar stratospheric cloud development within the polar stratosphere.
Sayarlioglu, Hayriye; Topal, Cevat; Sayarlioglu, Mehmet; Dulger, Haluk; Dogan, Ekrem; Erkoc, Reha
2004-01-01
OBJECTIVE: It is known that glucose concentrations of peritoneal dialysis solutions are detrimental to the peritoneal membrane. In order to determine the effect of glucose concentration on cytokine levels of peritoneal fluid of continuous ambulatory peritoneal dialysis (CAPD) patients, a cross-sectional study was performed. METHODS: Nine non-diabetic CAPD patients participated in two 8-h dwell sessions of overnight exchanges in consecutive days, with 1.36% and 3.86% glucose containing peritoneal dialysis solutions (Baxter-Eczacibas). Peritoneal dialysis fluid tumor necrosis factor (TNF)-alpha and interleukin (IL)-6 levels were measured. RESULTS: TNF-alpha levels after 1.36% and 3.86% glucose used dwells were 23+/-14 pg/ml and 28+/-4 pg/ml, respectively (p=0.78). The IL-6 levels were 106+/-57 pg/ml and 115+/-63 pg/ml (p=0.81), respectively. CONCLUSION: In our in vivo study we found that the glucose concentration of the conventional lactate-based CAPD solution has no effect on basal IL-6 and TNF-alpha levels of peritoneal fluid. Further in vivo studies with non-lactate-based CAPD solutions are needed in order to determine the effect of glucose concentration per se on cytokine release. PMID:15203553
Fu, Xiuli; Chen, Lingxin; Li, Jinhua
2012-08-21
A novel colorimetric method was developed for ultrasensitive detection of heparin based on self-assembly of gold nanoparticles (AuNPs) onto the surface of graphene oxide (GO). Polycationic protamine was used as a medium for inducing the self-assembly of citrate-capped AuNPs on GO through electrostatic interaction, resulting in a shift in the surface plasmon resonance (SPR) absorption of AuNPs and exhibiting a blue color. Addition of polyanionic heparin disturbed the self-assemble of AuNPs due to its strong affinity to protamine. With the increase of heparin concentration, the amounts of self-assembly AuNPs decreased and the color changed from blue to red in solution. Therefore, a "blue-to-red" colorimetric sensing strategy based on self-assembly of AuNPs could be established for heparin detection. Compared with the commonly reported aggregation-based methods ("red-to-blue"), the color change from blue to red was more eye-sensitive, especially in low concentration of target. Moreover, stronger interaction between protamine and heparin led to distinguish heparin from its analogues as well as various potentially coexistent physiological species. The strategy was simply achieved by the self-assembly nature of AuNPs and the application of two types of polyionic media, showing it to be label-free, simple, rapid and visual. This method could selectively detect heparin with a detection limit of 3.0 ng mL(-1) in standard aqueous solution and good linearity was obtained over the range 0.06-0.36 μg mL(-1) (R = 0.9936). It was successfully applied to determination of heparin in fetal bovine serum samples as low as 1.7 ng mL(-1) with a linear range of 0-0.8 μg mL(-1).
Nivsarkar, Manish; Patel, Ketan R.; Patel, Dixit D.
2015-01-01
Introduction Different topical formulations of diclofenac have varying skin penetration profile. Recent advances in science and technology has led to the development of many new formulations of drugs for topical drug delivery. One such technological development has led to the innovation of Dynapar QPS, a novel, non-aqueous, quick penetrating solution (QPS) of diclofenac diethylamine. Aim This study was aimed to measure the total exposure from the drug penetrating the skin in healthy human subjects and comparing the relative systemic bioavailability of Dynapar QPS® with diclofenac emulgel. Materials and Methods A 200 mg of diclofenac from either Dynapar QPS® (5 ml) or emulgel (20 g) was applied on back of subject as per the randomisation schedule. Blood samples were collected up to 16 hours post drug application. Plasma concentration of diclofenac was measured by pre-validated HPLC method. Pharmacokinetic (PK) parameters like Cmax, Tmax, t1/2, AUC0-t, AUC0-∞, and Kel, of diclofenac were determined for both the formulations. Results Mean Cmax after administration of Dynapar QPS® and diclofenac emulgel were 175.93 and 40.04 ng/ml, respectively. Tmax of diclofenac was almost half with QPS compared to emulgel (5.24 hrs versus 9.53 hrs respectively). The mean AUC0–t and AUC0-∞ after administration of Dynapar QPS® was higher as compared to diclofenac emulgel (AUC0–t: 1224.19 versus 289.78 ng.h/ml, respectively; AUC0-∞: 1718.21 versus 513.83 ng.h/ml, respectively). None of the subject experienced any adverse event during the study. Conclusion The results indicate an enhanced penetration and subsequent absorption of diclofenac from Dynapar QPS® as compared to diclofenac emulgel. Higher penetration is likely to translate into better pain relief in patients. PMID:26816910
Nivsarkar, Manish; Maroo, Sanjaykumar H; Patel, Ketan R; Patel, Dixit D
2015-12-01
Different topical formulations of diclofenac have varying skin penetration profile. Recent advances in science and technology has led to the development of many new formulations of drugs for topical drug delivery. One such technological development has led to the innovation of Dynapar QPS, a novel, non-aqueous, quick penetrating solution (QPS) of diclofenac diethylamine. This study was aimed to measure the total exposure from the drug penetrating the skin in healthy human subjects and comparing the relative systemic bioavailability of Dynapar QPS(®) with diclofenac emulgel. A 200 mg of diclofenac from either Dynapar QPS(®) (5 ml) or emulgel (20 g) was applied on back of subject as per the randomisation schedule. Blood samples were collected up to 16 hours post drug application. Plasma concentration of diclofenac was measured by pre-validated HPLC method. Pharmacokinetic (PK) parameters like Cmax, Tmax, t1/2, AUC0-t, AUC0-∞, and Kel, of diclofenac were determined for both the formulations. Mean Cmax after administration of Dynapar QPS(®) and diclofenac emulgel were 175.93 and 40.04 ng/ml, respectively. Tmax of diclofenac was almost half with QPS compared to emulgel (5.24 hrs versus 9.53 hrs respectively). The mean AUC0-t and AUC0-∞ after administration of Dynapar QPS(®) was higher as compared to diclofenac emulgel (AUC0-t: 1224.19 versus 289.78 ng.h/ml, respectively; AUC0-∞: 1718.21 versus 513.83 ng.h/ml, respectively). None of the subject experienced any adverse event during the study. The results indicate an enhanced penetration and subsequent absorption of diclofenac from Dynapar QPS(®) as compared to diclofenac emulgel. Higher penetration is likely to translate into better pain relief in patients.
The Performance of the Abbott i2000 for Measuring Serum Markers of Infectious Diseases.
Wang, Linchuan; Chen, Wei; Yu, Yan
2017-01-01
To date, there is a trend that the chemiluminescent microparticle immunoassays (CMIA) and electrochemiluminescence immunoassays (ECIA) technology gradually replacing the enzyme-linked immunosorbent assay (ELISA). But the performance such as the limit of quantitation (LOQ), precision, linear range of CMIA, or ECIA for serum markers of infectious diseases has rarely been reported. Using proficiency testing samples and standard materials, we confirmed the LOQ of the ELISA and the precision, linear range, LOQ, and instrument biases of the Abbott i2000 for eight serum markers. We used the Abbott i2000 and ELISAs to assess five HIV samples; the researchers were blinded to the true status of the samples. For the Abbott i2000, the coefficients of variation (CV) for the low, medium, and high concentration samples ranged from 1.06 to 12.74%, which were less than the allowable error; the linear ranges of HBsAg and HBsAb were 0.66-304.11 IU/ml and 8.16-1205.9 mIU/ml, respectively. For the Abbott i2000, the LOQs of HBsAg, HBsAb, HBeAg, HBeAb, HBcAb, anti-HCV, anti-TP, and anti-HIV were 0.026 IU/ml, 4 mIU/ml, 0.14 NCU/ml, 0.56 NCU/ml, 0.99 NCU/ml, 0.5 NCU/ml, 8.8 mIU/ml, and 1.92 NCU/ml, respectively, and these values were 0.16 IU/ml, 6.97 mIU/ml, 1.16 NCU/ml, 1.63 NCU/ml, 1.79 NCU/ml, 1.03 NCU/ml, 8.33 mIU/ml, and 1.3 NCU/ml, respectively, for the ELISA. When five HIV samples were blindly assessed, two cases were missed by the Abbott i2000 and the ELISA results were consistent with the expected results. The Abbott i2000 performed significantly better than the ELISA on HBV and HCV screening; however, for anti-TP and anti-HIV, the ELISA remained the preferred method. © 2016 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Nováková, E.; Linhart, O.; Červený, V.; Rychlovský, P.; Hraníček, J.
2017-08-01
This paper proposes a method for determination of selenium content in samples of dietary supplements using TiO2 mediated UV-photochemical vapor generation with quartz furnace atomic spectrometric detection. The flow-injection method was optimized for determination of selenium in the form of selenite or selenate ions. The limits of detection of the proposed method are 0.89 ng mL- 1 and 0.68 ng mL- 1 for selenite and selenate, respectively. Extraction in neutral medium was used for the leaching of selenate and NaOH solution was used for the leaching of selenite. The methods accuracy was verified against the declared amounts of Se in five different samples of over-the-counter dietary supplements and on NIST SRM 3280. The method was also compared to results achieved with determination by electrothermal atomization atomic absorption spectrometry following microwave decomposition. The recovery of selenium during sample preparation was tested by spiking the tablets prior to extraction and estimated to be approximately 100%. An interference study has been carried out to estimate the effect of concomitant elements on the methods accuracy.
Yousefi, Seyed Reza; Ahmadi, Seyed Javad; Shemirani, Farzaneh; Jamali, Mohammad Reza; Salavati-Niasari, Masoud
2009-11-15
A new synthesized modified mesoporous silica (MCM-41) using 5-nitro-2-furaldehyde (fural) was applied as an effective sorbent for the solid phase extraction of uranium(VI) and thorium(IV) ions from aqueous solution for the measurement by inductively coupled plasma optical emission spectrometry (ICP OES). The influences of some analytical parameters on the quantitative recoveries of the analyte ions were investigated in batch method. Under optimal conditions, the analyte ions were sorbed by the sorbent at pH 5.5 and then eluted with 1.0 mL of 1.0 mol L(-1) HNO(3). The preconcentration factor was 100 for a 100mL sample volume. The limits of detection (LOD) obtained for uranium(VI) and thorium(IV) were 0.3 microg L(-1). The maximum sorption capacity of the modified MCM-41 was found to be 47 and 49 mg g(-1) for uranium(VI) and thorium(IV), respectively. The sorbent exhibited good stability, reusability, high adsorption capacity and fast rate of equilibrium for sorption/desorption of uranium and thorium ions. The applicability of the synthesized sorbent was examined using CRM and real water samples.
Zheng, Yu; Chen, Xiong; Zhou, Mei; Wang, Meng-jun; Wang, Jin-hai; Li, Gang; Cui, Jun
2015-10-01
It is important to real-timely monitor and control the temperature of cell physiological solution in patch clamp experiments, which can eliminate the uncertainty due to temperature and improve the measurement accuracy. This paper studies the influence of different ions at different concentrations in the physiological solution on precision of a temperature model by using near infrared spectroscopy and chemometrics method. Firstly, we prepared twelve sample solutions respectively with the solutes of CaCl2, KCl and NaCl at four kinds of concentrations, and collected the spectra of different solutions at the setting temperature range 20-40 degrees C, the range of the spectra is 9 615-5 714 cm(-1). Then we divided the spectra of each solution at different temperatures into two parts (a training set and a prediction set) by three methods. Interval partial least squares method was used to select an effective wavelength range and develop calibration models between the spectra in the selected range and temperature velues. The experimental results show that RMSEP of CaCl2 solution with 0.25 g x mL(-1) is maximum, the result of the three tests are 0.386 3, 0.303 7 and 0.337 2 degrees C, RMSEP of NaCl with 0.005 g x mL(-1) solution is minimum, the result of the three tests are 0.220 8, 0.155 3 and 0.145 2 degrees C. The experimental results indicate that Ca2+ has the greatest influence on the accuracy of the temperature model of the cell physiological solution, then K+, and Na+ has the least influence. And with the ionic concentration increasing, the model accuracy decreases. Therefore; when we build the temperature model of cell physiological solution, it is necessary to change the proportion of the three kinds of main ions in cell physiological solution reasonably in order to correct the effects of different ionic concentrations in physiological solution and improve the accuracy of temperature measurements by near infrared spectroscopy.
Matsumoto, Taiichi; Kakinoki, Ryosuke; Ikeguchi, Ryosuke; Hyon, Suong-Hyu; Nakamura, Takashi
2005-06-30
Our previous study demonstrated successful peripheral nerve storage for 1 month using polyphenol solution. We here report two studies to solve residual problems in using polyphenols as a storage solution for peripheral nerves. Study 1 was designed to determine the optimal concentration of the polyphenol solution and the optimal immersion period for nerve storage. Rat sciatic nerve segments were immersed in polyphenol solution at three different concentrations (2.5, 1.0, and 0.5 mg/ml) for three different periods (1, 7, and 26 days). Electrophysiological and morphological studies demonstrated that nerve regeneration from nerve segments that had been immersed in 1mg/ml polyphenol solution for 1 week and in Dulbecco's modified Eagle's medium (DMEM) for the subsequent 3 weeks was superior to the regeneration in other treatment groups. In study 2, the permeability of nerve tissue to polyphenol solution was investigated using canine sciatic nerve segments stored in 1.0mg/ml polyphenol solution for 1 week and in DMEM for the subsequent 3 weeks. Electron microscopy revealed that the Schwann cell structure within 500-700 microm of the perineurium was preserved, but cells deeper than 500-700 microm were badly damaged or had disappeared. The infiltration limit for polyphenol solution into neural tissue is inferred to be 500-700 microm.
Beyki, Mostafa Hossein; Shemirani, Farzaneh; Khani, Rouhollah
2014-01-01
In this work, the nanoclay was intercalated with acyclovir (9-[(2-hydroxyethoxy) methyl] guanine), the toxicity of which to mammalian cells is very low. We used no organic solvents for preparation of modified clay and desorption of Cu ions from the sorbent. Batch and column methods were used, and sorption of Cu was quantitative (>98%) in the pH range of 7.5 to 10.0. Quantitative desorption occurred with 5.0 mL of 3.0 M HCl, and the amount of Cu(II) was measured by using flame atomic absorption spectrometry. In the initial solution the linear dynamic range and the LOD were 3.0-1000.0 and 0.58 μg/L, respectively. With 500.0 mL of sample, an enrichment factor of 100 was obtained. The RSD was 2.0% (n = 8, concentration = 0.5 mg/L), and the maximum capacity of the sorbent was 45.0 mg/g. The influence of experimental parameters including sample pH, ionic strength, type and volume of the eluent, and interference of some ions on the recoveries of Cu was investigated. The proposed method using a new and easier prepared solid sorbent was applied to the determination of Cu in different real samples with satisfactory results.
Cassella, Ricardo J; Salim, Verĵnica A; Garrigues, Salvador; Santelli, Ricardo E; de la Guardia, Miguel
2002-11-01
This paper reports on a new strategy for the slurry sampling determination of dithiocarbamate pesticide zineb [[ethylenebis(dithiocarbamato)]zinc] employing a FIA system with a flame atomic absorption spectrometry detector. In the flow system, an on-line alkaline hydrolysis of the pesticide is performed, allowing the release of Zn(II) ions to the solution, which are easily detected by a flame AAS technique. Several parameters that could affect the performance of the analytical methodology were studied, such as the concentration of NH3(aq) used in the hydrolysis step, the effect of the presence of Triton X-100 on the sensitivity and precision, and the FIA parameters (carrier flow rate and mixing coil volume). Under optimized conditions, aqueous slurries containing 2.5 to 25 microg ml(-1) zineb provided good linear calibration fits. From the obtained data, a detection limit (3sigma) of 1.0 microg ml(-1) zineb was found and a repeatability of 2.7% was obtained from 12 measurements of a slurry containing 2.5 microg m(-1) zineb. On the other hand, a precision (reproducibility) of 7.8% was achieved from three determinations of a sample containing 128 mg g(-1) of the pesticide. Also, the developed system provides a sampling frequency of 72 h(-1).
Destro, M. T.; Leitao, M.; Farber, J. M.
1996-01-01
Volume 62, no. 2, p. 705, column 2, line 5 from bottom: "neutralized with chlorine" should read "chlorine neutralized by the addition of 5 ml of a 1% solution of sodium thiosulfate." Page 706, Table 1, footnote b: Footnote b should read "The designation in parentheses is the area or type of sample collected as indicated in Table 3." Page 709, Tables 3 and 4: Tables 3 and 4 should read as shown below. PMID:16535326
2011-09-01
the spore and the active areas on the Klarite surface. For these experiments an aliquot of the common bacillus spore B. coagulans was drop...suspension B. coagulans (ATCC SUS-CG) was purchased from Raven Biologicals and used at a log 4 or 6 population per 0.1 mL of solution. For experiments...Klarite substrates were evaluated with the spore sample B. coagulans . In these experiments different substrates and the changes in overall band
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karimi, A.R.
In this study a method for the measurement of uranium in natural waters at sub-ppB concentration levels by the separation and determination of U/sup 4 +/ and UO/sub 2//sup 2 +/ species is proposed. Reversed phase high performance liquid chromatography, followed by a post-column reaction and a sensitive UV-visible detection system was the method of choice to determine qualitatively and quantitatively the two uranium species. Also a cation-exchange and fluorescence detection system was studied for separation and determination of UO/sub 2//sup 2 +/ ions. Uranyl ion was selectively complexed with L-phenylalanine moetie in the sample solution containing U/sup 4 +/more » ions. Uranium (IV)/U(VI)-ligand was separated on a C/sub 18/ column with acetate buffer. Hexanesulfonate was found to be the choice for ion-pair reagent. The separation was best done with the acetate buffer at .01 M concentration and pH of 3.5. Absorption of the two species were measured after a post-column reaction with Arsenazo-III. Chromatographic parameters were calculated and a calibration curves were constructed. The detection limit for the procedure was 0.7 ..mu..g/mo and 1.2..mu..g/ml for U(IV) and U(VI) respectively. When U(VI) was separated on the cation-exchange column the limit of detection was calculated to be 1 ..mu..g/ml. The direct fluorometric method for U(VI) measurement results in a detection limit of 2 ppB and upper concentration limit of 2 ppM. The effect of interfering ions in the direct method of determination could be eliminated by dilution of sample solution.« less
Erice, Alejo; Brambilla, Donald; Bremer, James; Jackson, J. Brooks; Kokka, Robert; Yen-Lieberman, Belinda; Coombs, Robert W.
2000-01-01
The QUANTIPLEX HIV-1 RNA assay, version 3.0 (a branched DNA, version 3.0, assay [bDNA 3.0 assay]), was evaluated by analyzing spiked and clinical plasma samples and was compared with the AMPLICOR HIV-1 MONITOR Ultrasensitive (ultrasensitive reverse transcription-PCR [US-RT-PCR]) method. A panel of spiked plasma samples that contained 0 to 750,000 copies of human immunodeficiency virus type 1 (HIV-1) RNA per ml was tested four times in each of four laboratories (1,344 assays). Negative results (<50 copies/ml) were obtained in 30 of 32 (94%) assays with seronegative samples, 66 of 128 (52%) assays with HIV-1 RNA at 50 copies/ml, and 5 of 128 (4%) assays with HIV-1 RNA at 100 copies/ml. The assay was linear from 100 to 500,000 copies/ml. The within-run standard deviation (SD) of the log10 estimated HIV-1 RNA concentration was 0.08 at 1,000 to 500,000 copies/ml, increased below 1,000 copies/ml, and was 0.17 at 100 copies/ml. Between-run reproducibility at 100 to 500 copies/ml was <0.10 log10 in most comparisons. Interlaboratory differences across runs were ≤0.10 log10 at all concentrations examined. A subset of the panel (25 to 500 copies/ml) was also analyzed by the US-RT-PCR assay. The within-run SD varied inversely with the log10 HIV-1 RNA concentration but was higher than the SD for the bDNA 3.0 assay at all concentrations. Log-log regression analysis indicated that the two methods produced very similar estimates at 100 to 500 copies/ml. In parallel testing of clinical specimens with low HIV-1 RNA levels, 80 plasma samples with <50 copies/ml by the US-RT-PCR assay had <50 copies/ml when they were retested by the bDNA 3.0 assay. In contrast, 11 of 78 (14%) plasma samples with <50 copies/ml by the bDNA 3.0 assay had ≥50 copies/ml when they were retested by the US-RT-PCR assay (median, 86 copies/ml; range, 50 to 217 copies/ml). Estimation of bDNA 3.0 values of <50 copies/ml by extending the standard curve of the assay showed that these samples with discrepant results had higher HIV-1 RNA levels than the samples with concordant results (median, 34 versus 17 copies/ml; P = 0.0051 by the Wilcoxon two-sample test). The excellent reproducibility, broad linear range, and good sensitivity of the bDNA 3.0 assay make it a very attractive method for quantitation of HIV-1 RNA levels in plasma. PMID:10921936
Choleva, Tatiana G; Kappi, Foteini A; Tsogas, George Z; Vlessidis, Athanasios G; Giokas, Dimosthenis L
2016-05-01
This work describes a new method for the extraction and determination of gold nanoparticles in environmental samples by means of in-situ suspended aggregate microextraction and electrothermal atomic absorption spectrometry. The method relies on the in-situ formation of a supramolecular aggregate phase through ion-association between a cationic surfactant and a benzene sulfonic acid derivative. Gold nanoparticles are physically entrapped into the aggregate phase which is separated from the bulk aqueous solution by vacuum filtration on the surface of a cellulose filter in the form of a thin film. The film is removed from the filter surface and is dissociated into an acidified methanolic solution which is used for analysis. Under the optimized experimental conditions, gold nanoparticles can be efficiently extracted from water samples with recovery rates between 81.0-93.3%, precision 5.4-12.0% and detection limits as low as 75femtomolL(-1) using only 20mL of sample volume. The satisfactory analytical features of the method along with the simplicity indicate the efficiency of this new approach to adequately collect and extract gold nanoparticle species from water samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Junsomboon, Jaroon; Jakmunee, Jaroon
2008-07-15
A simple flow injection system using three 3-way solenoid valves as an electric control injection valve and with a simple home-made chloride ion selective electrode based on Ag/AgCl wire as a sensor for determination of water soluble chloride in admixtures and aggregates for cement has been developed. A liquid sample or an extract was injected into a water carrier stream which was then merged with 0.1M KNO(3) stream and flowed through a flow cell where the solution will be in contact with the sensor, producing a potential change recorded as a peak. A calibration graph in range of 10-100 mg L(-1) was obtained with a detection limit of 2 mg L(-1). Relative standard deviations for 7 replicates injecting of 20, 60 and 90 mg L(-1) chloride solutions were 1.0, 1.2 and 0.6%, respectively. Sample throughput of 60 h(-1) was achieved with the consumption of 1 mL each of electrolyte solution and water carrier. The developed method was validated by the British Standard methods.
[Quantitative analysis of Cu in water by collinear DP-LIBS].
Zheng, Mei-Lan; Yao, Ming-Yin; Chen, Tian-Bing; Lin, Yong-Zeng; Li, Wen-Bing; Liu, Mu-Hua
2014-07-01
The purpose of this research is to study the influence of double pulse laser induced breakdown spectroscopy (DP-LIBS) on the sensitivity of Cu in water. The water solution of Cu was tested by collinear DP-LIBS in this article. The results show that spectral intensity of Cu can be enhanced obviously by DP-LIBS, compared with single pulse laser induced breakdown spectroscopy (SP-LIBS). Besides, the experimental results were significantly impacted by delay time between laser pulse and spectrometer acquisition, delay time of double laser pulse and energy of laser pulse and so on. The paper determined the best conditions for DP-LIBS detecting Cu in water. The optimal acquisition delay time was 1 380 ns. The best laser pulse delay time was 25 ns. The most appropriate energy of double laser pulse was 100 mJ. Characteristic analysis of spectra of Cu at 324.7 and 327.4 nm was done for quantitative analysis. The detection limit was 3.5 microg x mL(-1) at 324.7 nm, and the detection limit was 4.84 microg x mL(-1) at 327.4 nm. The relative standard deviation of the two characteristic spectral lines was within 10%. The calibration curve of characteristic spectral line, established by 327.4 nm, was verified with 500 microg x mL(-1) sample. Concentration of the sample was 446 microg x mL(-1) calculated by the calibration curve. This research shows that the detection sensitivity of Cu in water can be improved by DP-LIBS. At the same time, it had high stability.
NASA Astrophysics Data System (ADS)
Milošević, Maja; Logar, Mihovil; Dojčinović, Biljana; Erić, Suzana
2015-04-01
Cation exchange capacity (CEC) represents one of the most important parameters of clay minerals which reflects their ability to exchange cations with liquid phases in near contact. Measurement of CEC is used for characterizing sample plasticity, adsorbing and swelling properties which later define their usage in industrial purposes. Several methods have been developed over the years for determination of layer charge, charge density, charge distribution, etc. and have been published in numerous papers (Czimerova et al., 2006; Yukselen and Kaya, 2008). The main goal of present study is comparison of suitability of more recent method - methylene blue test in regard to older method - ammonium acetate for determination of CEC. For this study, we selected one montmorillonite clay (Bogovina, Serbia) and two mainly kaolinite clays (Miličinica, Serbia). Chemicals used for CEC determinations were solution of methylene blue (MB)(14*10-6M/ml) and ammonium acetate (AA) solution (1M). The obtained results are showing generally lower values in case of MB method. The main difference is due to molecular aggregation of MB on the clay surface. AA method is highly sensitive to the presence of CaO. Release of Ca ion from the sample into the solution can limit the saturation of exchange sites by the ammonium ion. This is clearly visible in case of montmorillonite clay. Fe2+ and Mg ions are difficult to move by the ammonium ion because of their ion radius, but in case of MB molecule there is no such restriction in removing them from the exchange sites. MB solution, even in a low concentration (2*10-6M/ml), is showing preferable results in moving the ions from their positions which is already visible after adding a small quantity of solution (25cm3). Both MB-titration and MB-spot test yield similar results and are much simpler methods than AA and they also give other information such as specific surface area (external and internal) whereas AA method only provides information about cations in exchangeable positions. Both methods, methylene blue test and ammonium acetate method, have advantages and disadvantages and differ in their requirements for the sample preparations but in general method selection is depending on the specific application of the given sample. References: - Yukselen, Y. and Kaya, A., Engineering Geology 102 (2008) 38-45 - Czimerova, A., Bujdak, J. and Dohrmann, R., Applied Clay Science 34 (2006) 2-13
Sümpelmann, R; Schürholz, T; Marx, G; Ahrenshop, O; Zander, R
2003-09-01
The composition of normal saline (NaCl), the standard wash solution for cell saver autotransfusion, is considerably different from physiologic plasma values in small infants. Therefore, we investigated acid-base and electrolyte changes during massive cell saver autotransfusion with different wash solutions in young pigs. After approval by the animal protection authorities 15 young pigs (weight 10.6 +/- 1.1 kg, blood volume 848 +/- 88 ml, mean+/-SD) underwent 15 cycles of cell saver autotransfusion (Haemolite 2plus, Haemonetics). For each cycle, 100 ml arterial blood was withdrawn, washed with NaCl, physiologic multielectrolyte solution (PME, V Infusionslösung 296 mval Elektrolyte, Baxter) or physiologic erythrocyte protection solution (PEP, 3.2 % gelatine, pH 7.40, cHCO3 24 mmol/l), and then retransfused. Analyses of acid-base, electrolyte, and hematologic parameters were performed for systemic and washed blood samples. For NaCl there was a progressive decrease in systemic pH, HCO3 and base excess (BE) and an increase in chloride values (Cl) (p < 0.05). Use of PME slightly decreased pH (n. s.), whereas HCO3, BE and Cl remained stable. PEP slightly increased pH, HCO3 and BE, and decreased Cl (n. s.). Free hemoglobin increased in NaCl and PME (p < 0.05) and was below baseline in PEP (n. s.). Lactic acid course was comparable in all groups. The use of NaCl as wash solution for massive autotransfusion resulted in metabolic acidosis caused by dilution of HCO3 and increased Cl values. Fewer systemic acid-base and electrolyte changes were observed, when blood was washed with PME or PEP. The decreased hemoglobin release with PEP is possibly due to a gelatine specific electrostatic surface coating of erythrocyte membranes. For massive transfusion of washed red blood cells, physiologic multielectrolyte solution and physiologic erythrocyte protection solution should be preferred to NaCl, especially for small infants.
NASA Astrophysics Data System (ADS)
Kumar, Praveen; Burman, Uday; Santra, P.
2015-07-01
Experiments were carried out to study the effect of zinc oxide nanoparticles (nano-ZnO) on nitrogenase activity in legumes. In the first experiment, nodulated roots of cluster bean, moth bean, green gram and cowpea were dipped in Hoagland solution containing 1.5 and 10 μg mL-1 of nano-ZnO for 24 h. Nitrogenase activity in cluster bean, green gram and cowpea roots increased after dipping in solution containing 1.5 μg mL-1 nano-ZnO, but decreased in roots dipped in solution containing 10 μg mL-1 nano-ZnO. However, in moth bean roots, nitrogenase activity decreased after dipping in solution containing either concentration of nano-ZnO. In the second experiment, nodulated roots of green gram were dipped in Hoagland solution containing 1, 4, 6, 8 and 10 μg mL-1 nano-ZnO for 6-30 h before estimating nitrogenase activity. Results showed that an interactive effect of nano-ZnO concentration and exposure time influenced nitrogenase activity. The possible reasons behind this effect have been discussed. A model [ A = 3.44 + 0.46 t - 0.01 t 2 - 0.002 tc 2 ( R 2 = 0.81)] involving linear and power components was developed to simulate the response of nitrogenase activity in green gram roots to the concentration and exposure time of nano-ZnO.
Zand, Vahid; Mokhtari, Hadi; Reyhani, Mohammad-Frough; Nahavandizadeh, Neda; Azimi, Shahram
2017-11-01
The aim of the present study was to compare the amount of the smear layer remaining in prepared root canals with different protocols of Bio RaCe files and XP-endo Finisher file (XPF) in association with 17% EDTA and sodium hypochlorite solution. A total of 68 extracted single-rooted teeth were randomly divided into 4 experimental groups (n=14) and two control groups (n=6). The root canals were prepared with Bio RaCe files (FKG Dentaire, Switzerland) using the crown-down technique based on manufacturer's instructions and irrigated according to the following irrigation techniques: Group 1: XPF with 2 mL of 2.5% NaOCl for 1 minute. Group 2:, XPF with 1 mL of 17% EDTA for one minute. Group 3: XPF was used for 1 minute in association with normal saline solution. Group 4: XP-endo Finisher file for 30 seconds in association with 2.5% NaOCl and 17% EDTA for 30 seconds. The negative control group: NaOCl (2.5%) was used during root canal preparation, followed by irrigation with 17% EDTA at the end of root canal preparation. The positive control group: Normal saline solution was used for irrigation during root canal preparation. In all the groups, during preparation of the root canals with Bio RaCe file, 20 mL of 2.5% NaOCl was used for root canal irrigation and at the end of the procedural steps 20 mL of normal saline solution was used as a final irrigant. The samples were analyzed under SEM at ×1000‒2000 magnification and evaluated using Torabinejad scoring system. Data were analyzed with non-parametric Kruskal-Wallis test and post hoc Mann-Whitney U test, using SPSS. Statistical significant was defined at P <0.05. The results of the study showed the least amount of the smear layer at coronal, middle and apical thirds of the root canals in groups 2, which was not significantly different from the negative control group ( P <0.5). Under the limitations of the present study, use of a combination of NaOCl and EDTA in association with XPF exhibited the best efficacy for the removal of the smear layer. Key words: Smear layer, XP-endo Finisher file, EDTA, Sodium hypochlorite.
Speciation of cadmium and zinc with application to soil solutions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holm, P.E.; Christensen, T.H.; Tjell, J.C.
1995-01-01
A two-part method has been developed for determination of Cd and Zn species in 50-mL soil solution samples containing low concentrations of Cd and Zn (1-10 {mu}g Cd L{sup -1} and 50-1000 {mu}g Zn L{sup -1}). The method uses two cation exchange resins (Amberlite CG 120 and Chelex 100) in a batch-column-batch procedure and relies on analytical determinations of Cd and Zn by graphite furnace atomic absorption spectrophotometry. The first part (batch) of the method allows determination of free divalent Cd{sup 2+} and Zn{sup 2+}. This part is experimentally sensitive to cation concentrations and ionic strength and these parameters shouldmore » be controlled during the experimental procedures. However, it is shown that Cd and Zn concentrations and pH do not influence the method. Speciations performed on samples containing chloride and sulfate were in accordance with theoretical calculations. The second part (column-batch) of the method operationally separates the complexed fraction into labile complexes, slowly labile complexes, and stable complexes. Chloro complexes were identified as labile complexes, while EDTA complexes were identified as stable complexes. The method works well with relatively small volumes of sample solutions and at low metal concentrations and may be useful in characterization of Cd and Zn in soil solutions. 12 refs., 6 figs., 3 tabs.« less
Albenzio, Marzia; Santillo, Antonella; Caroprese, Mariangela; Schena, Laura; Russo, Donatella Esterina; Sevi, Agostino
2011-11-01
This study was undertaken to assess the effect of somatic cell count in ewe milk on i) composition and hygienic traits; ii) plasmin, cathepsin and elastase activities; iii) leukocyte differential count; iv) renneting parameters. Individual ewe milk samples were grouped according to somatic cell count (SCC) into five classes: SC300 (<300 000 cells/ml), SC500 (from 301 000 to 500 000 cells/ml), SC1000 (from 501 000 to 1 000 000 cells/ml), SC2000 (from 1 001 000 to 2 000 000 cells/ml) and SC>2000 (>2 001 000 cells/ml). Individual milk samples were analysed for pH, chemical composition, microbial features, indigenous proteolytic enzymes, differential leukocyte population, and renneting parameters. Milk yield, lactose, protein, non casein nitrogen, microbial features were affected by SCC level. Plasmin and elastase activities were the highest in samples with more than 1 000 000 cells/ml; plasmin had intermediate values in samples with 300 000 to 1 000 000 cells/ml and the lowest in samples with less than 300 000 cells/ml of milk. Cathepsin D showed significantly lower values in SC300 and SC1000 classes than in SC500, SC2000 and SC>2000 classes. The highest percentages of lymphocyte were found in samples with less than 1 000 000 cells/ml, while the highest levels of polymorphonuclear leukocyte were found in samples with more than 1 000 000 cells/ml of milk. Longer clotting time was found in SC>2000 samples, while reduced clot firmness was observed in SC500 and SC>2000 samples. Results on milk yield and on compositional parameters evidenced an impairment of udder efficiency in ewe milk samples starting from 300 000 cells/ml. Plasmin activity in milk can be considered as a marker of the synthetic and secreting ability of the mammary gland; furthermore plasmin and elastase were consistent with the health status of the udder. Finally cathepsin D played a role in the worsening of renneting properties of ewe milk.
Borges, Caroline Cristina; Estrela, Carlos; Lopes, Fabiane Carneiro; Palma-Dibb, Regina Guenka; Pecora, Jesus Djalma; De Araújo Estrela, Cyntia Rodrigues; Sousa-Neto, Manoel Damião de
2017-11-01
The objective of this study was to evaluate the antibacterial effect and the ultrastructural alterations of diode laser with different wavelengths (808nm and 970nm) and its association with irrigating solutions (2.5% sodium hypochlorite and 2% chlorhexidine) in root dentin contaminated by a five days biofilm. Thirteen uniradicular teeth were sectioned into 100 dentin intraradicular blocks. Initially, the blocks were immersed for 5min in 17% EDTA and washed with distilled water for 5min, then samples were sterilized for 30min at 120°C. The dentin samples were inoculated with 0.1mL of E. faecalis suspension in 5mL BHI (Brain Heart Infusion) and incubated at 37°C for 5days. After contamination, the specimens were distributed into ten groups (n=10) according to surface treatment: GI - 5mL NaOCl 2.5%, GII - 5mL NaOCl 2.5%+808nm diode (0.1W for 20s), GIII - 5mL NaOCl 2.5%+970nm diode (0.5W for 4s), GIV - 808nm diode (0.1W for 20s), GV - 970nm diode (0.5W for 4s), GVI - CHX 2%, GVII - CHX 2%+808nm diode (0.1W for 20s), GVIII - CHX 2%+970nm diode (0.5W for 4s), GIX - positive control and GX - negative control. Bacterial growth was analyzed by turbidity and optical density of the growth medium by spectrophotometry (nm). Then, the specimens were processed for analysis ultrastructural changes of the dentin surface by SEM. The data was subject to the One-way ANOVA test. GI (77.5±12.1), GII (72.5±12.2), GIII (68.7±8.7), GV (68.3±8.7), GVI (62.0±5.5) and GVII (67.5±3.3) were statistically similar and statistically different from GIV (58.8±25.0), GVIII (59.2±4.0) and control groups (p<0.05). SEM analysis showed a modified amorphous organic matrix layer with melted intertubular dentin when dentin samples were irradiated with 970nm diode laser; erosion of the intertubular dentin in blocks submitted to 808nm diode laser irradiation; and an increased erosion of the intertubular dentin when 2.5% NaOCl was associated to the different wavelengths lasers. All the therapeutic protocols were able to reduce the bacterial contingent in dentin blocks, and the association of diode laser and solutions did not significantly improve the reduction of the bacterial contingent. Copyright © 2017 Elsevier B.V. All rights reserved.
Methyl bromide determination in selected foods by headspace technique.
Daft, J L
1993-01-01
A headspace method used earlier for determining methyl bromide (MB) in assorted nuts and peanut butters has been successfully applied to other foods that could potentially contain traces of this toxic fumigant. The foods tested include 63 off-the-shelf spices and seasonings, 83 table-ready items (grain-based, dried, or highly seasoned), 30 dried fruits and trail mixes, and 38 oil-based items (oil-seeds, cooking oils, or spicy oil-based dressings). Sample headspace gas is produced by blending < or = 50 g sample in 250 +/- 50 mL aqueous solution in a sealed 1000 mL blender cup. After equilibration at 25 degrees C, the headspace is sampled with a gas-tight syringe and injected into a dual column-dual detector gas chromatograph. One determination is made with a 20% OV-101 packed column and a 63Ni electron capture detector (ECD), the other with a GS-Q wide-bore capillary column and a Hall electrolytic conductivity detector (HECD). Of the approximately 200 samples tested, none contained detectable MB residue at a quantitation limit < 100 ng/g sample. All fortified samples yielded MB recovery. Samples were fortified at levels ranging from 78 to 3250 ng MB/g. Recoveries ranged from a mean high of 56% for spices and seasonings to a mean low of 30% for oil-based foods. The overall recovery and CV, including the results from assorted nuts and peanut butters, were 46 and 33%, respectively.
Chemical Stability of Telavancin in Elastomeric Pumps.
Sand, Patrick; Aladeen, Traci; Kirkegaard, Paul; LaChance, Dennis; Slover, Christine
2015-12-01
VIBATIV is a once-daily, injectable lipoglycopeptide antibiotic approved in the U.S. for the treatment of hospital-acquired and ventilator-associated bacterial pneumonia (HABP/VABP) caused by susceptible isolates of Staphylococcus aureus when alternative treatments are not suitable. In addition, VIBATIV is approved in the U.S. for the treatment of adult patients with complicated skin & skin structure infections (cSSSI) caused by susceptible isolates of Gram-positive bacteria, including Staphylococcus aureus, both methicillin-susceptible (MSSA) and methicillin-resistant (MRSA) strains. To evaluate the chemical stability of telavancin (Vibativ; Theravance Biopharma US, Inc, Northbrook, Illinois), a lipoglycopeptide antibiotic with activity against methicillin-resistant Staphylococcus aureus, in 2 types of elastomeric pumps, the Intermate Infusion System (Baxter International Inc) and the Homepump Eclipse (I-Flow Corporation). Different sizes of the Baxter (Ontario, Canada) (105 mL and 275 mL) and I-Flow (Stoughton, Massachusetts) (100 mL and 250 mL) pumps were compared with glass controls. The telavancin drug product was reconstituted and diluted to concentrations of 0.6 mg/mL and 8.0 mg/mL using either 0.9% saline, 5% dextrose in water, or sterilized water for injection (0.6 mg/mL telavancin) or saline (8.0 mg/mL telavancin) followed by Ringer's Lactate solution. Pumps were filled and stored at 2°C to 8°C, protected from light. Aliquots from both pump types and for all telavancin reconstitution/dilution schemes and concentrations were taken over a period of 8 days and analyzed for appearance, pH, telavancin concentration and purity, and degradation products. The pH of all pump solutions remained consistent throughout the 8-day analysis period, within a range of 4.6 to 5.7 for the 0.6 mg/mL and 4.4 to 4.9 for the 8.0 mg/mL telavancin solutions. There was no significant change in the chromatographic purity for any of the pump solutions examined. All decreases in telavancin concentration were ≤2.7%. Comparison of each test sample solution to the corresponding glass control indicated no loss of active drug due to absorption by the elastomeric material of the pumps. The greatest increase in the amount of total degradants observed over the 8-day period was ~0.7 w/w%. The results of this study indicate that telavancin remains chemically stable when diluted in the Intermate Infusion System and the Homepump Eclipse elastomeric pumps and stored at 2°C to 8°C for up to 8 days protected from light at the concentration range and dilution schemes evaluated.
Content determination of aniracetam in aniracetam inclusion complex by HPLC.
Li, Yongjian; Hu, Dejian; Sun, Yong
2009-01-01
We established a HPLC method for content determination of aniracetam in aniracetam inclusion complex. The chromato column was Agilent ODS (4.6mm x 150mm, 5 microm), the mobile phase was methanol-0.01 mol/L Potassium dihydrogen phosphate buffer solution (25:75, pH 3.0), with the flow rate of 1.0 ml/min, column temperature of 30 degrees and the detection wave at 280 nm, the sample size was 20microL. A good linear relationship was obtained between the peak areas and the concentrations of aniracetam in the range from 5- 80microg/ml (r=0.9998), the mean recovery was 100.1% (n=15), RSD=0.19%. This method is convenient, rapid, accurate, and brings about good recovery; it can be used for content determination of aniracetam in aniracetam inclusion complex.
Ensafi, Ali A; Khayamian, Taghi; Karbasi, Mohammad H
2003-06-01
An on-line system for enrichment and determination of lead(II) is presented. It is based on the adsorption of lead(II) ions on a minicolumn packed with active carbon loaded with Pyrogallol Red. After preconcentration step, the metal ions are eluted automatically by 5.0 ml of 0.50 M nitric acid solution and the lead ion contents were determined by atomic absorption spectrometry. The influence of chemicals, pH and flow variables were studied as well as effect of potential interfering ions. Under the optimum conditions, the lead ions in aqueous samples were concentrated about 100 fold by the column. The detection limit was 0.001 microg ml(-1). The recovery percent of spliced lead(II) was in the range of 98%-103%.
Culhaoglu, Ahmet Kursad; Özcan, Erdal; Kilicarslan, Mehmet Ali; Seker, Emre
2017-01-01
To compare the effect of boric acid solutions of different percentages to conventional irrigation solutions on the adhesive bond strength between fiber posts and radicular dentin surface with different cement types. One hundred fifteen extracted human incisors were endodontically instrumented to a length of 14-15 mm, and 12-mm post spaces were prepared with specific drills. Cylindrical fiber posts (Panavia Post) were luted with two different composite cements (Panavia F 2.0, Panavia SA) and cut into 1-mm-thick slices. These specimens were randomly allocated to 5 groups according to the irrigant applied: 1. control, no irrigant; 2. 10 ml of 2% chlorhexidine; 3. 10 ml of 5.25% NaOCl for 5 min and 10 ml of 17% EDTA for 3 min; 4. 10 ml of 5% boric acid solution at a temperature of 55°C for 60 s; 5. 10% boric acid solution, conditions as in group 4. Bond strength was determined using the push-out test. Microscopic assessment and SEM evaluations were performed in combination with push-out tests. The push-out bond strengths of cervical segments were significantly higher than for the middle and apical segments in all groups. The type of irrigation solution used significantly affected the bond strengths of the posts. The 10% boric acid solution and EDTA + NaOCl irrigation solutions provided the highest bond strengths (p < 0.005). SEM analysis showed that the dentin tubules were open and the smear layer was completely removed when EDTA/NaOCl and 10% boric acid were used as irrigation agents. Boric acid solutions, especially at a concentration of 10%, can be a viable alternative to the conventional irrigants used during endodontic treatment. The extent to which the 10% boric acid solution successfully removed the smear layer and the ease of rinsing boric acid from the root surface are advantageous.
Stabilization of Pt monolayer catalysts under harsh conditions of fuel cells
Zhang, Xiaoming; Liu, Ping; Yu, Shansheng; ...
2015-05-21
We employed density functional theory (DFT) to explore the stability of core (M = Cu, Ru, Rh, Pd, Ag, Os, Ir, Au)-shell (Pt) catalysts under harsh conditions, including solutions and reaction intermediates involved in the oxygen reduction reaction (ORR) in fuel cells. A pseudomorphic surface alloy (PSA) with a Pt monolayer (Pt 1ML) supported on an M surface, Pt 1ML/M(111) or (001), was considered as a model system. Different sets of candidate M cores were identified to achieve a stable Pt 1ML shell depending on the conditions. In vacuum conditions, the Pt 1ML shell can be stabilized on the mostmore » of M cores except Cu, Ag, and Au. The situation varies under various electrochemical conditions. Depending on the solutions and the operating reaction pathways of the ORR, different M should be considered. Pd and Ir are the only core metals studied, being able to keep the Pt ML shell intact in perchloric acid, sulfuric acid, phosphoric acid, and alkaline solutions as well as under the ORR conditions via different pathways. Ru and Os cores should also be paid attention, which only fall during the ORR via the *OOH intermediate. Rh core works well as long as the ORR does not undergo the pathway via *O intermediate. Our results show that PSAs can behave differently from the near surface alloy, Pt 1ML/M 1ML/Pt(111), highlighting the importance of considering both chemical environments and the atomic structures in rational design of highly stable core-shell nanocatalysts. Finally, the roles that d-band center of a core M played in determining the stability of supported Pt 1ML shell were also discussed.« less
Stabilization of Pt monolayer catalysts under harsh conditions of fuel cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Xiaoming; Yu, Shansheng; Zheng, Weitao, E-mail: wtzheng@jlu.edu.cn, E-mail: pingliu3@bnl.gov
2015-05-21
We employed density functional theory to explore the stability of core (M = Cu, Ru, Rh, Pd, Ag, Os, Ir, Au)-shell (Pt) catalysts under harsh conditions, including solutions and reaction intermediates involved in the oxygen reduction reaction (ORR) in fuel cells. A pseudomorphic surface alloy (PSA) with a Pt monolayer (Pt{sub 1ML}) supported on an M surface, Pt{sub 1ML}/M(111) or (001), was considered as a model system. Different sets of candidate M cores were identified to achieve a stable Pt{sub 1ML} shell depending on the conditions. In vacuum conditions, the Pt{sub 1ML} shell can be stabilized on the most ofmore » M cores except Cu, Ag, and Au. The situation varies under various electrochemical conditions. Depending on the solutions and the operating reaction pathways of the ORR, different M should be considered. Pd and Ir are the only core metals studied, being able to keep the Pt{sub ML} shell intact in perchloric acid, sulfuric acid, phosphoric acid, and alkaline solutions as well as under the ORR conditions via different pathways. Ru and Os cores should also be paid attention, which only fall during the ORR via the *OOH intermediate. Rh core works well as long as the ORR does not undergo the pathway via *O intermediate. Our results show that PSAs can behave differently from the near surface alloy, Pt{sub 1ML}/M{sub 1ML}/Pt(111), highlighting the importance of considering both chemical environments and the atomic structures in rational design of highly stable core-shell nanocatalysts. Finally, the roles that d-band center of a core M played in determining the stability of supported Pt{sub 1ML} shell were also discussed.« less
Niu, Zongliang; Yu, Chunwei; He, Xiaowen; Zhang, Jun; Wen, Yingying
2017-09-05
A salting-out assisted liquid-liquid extraction (SALLE) combined with gas chromatography-mass spectrometry (GC-MS) method was developed for the determination of four pyrethroid insecticides (PYRs) in high salinity and biological samples. Several parameters including sample pH, salting-out solution volume and salting-out solution pH influencing the extraction efficiency were systematically investigated with the aid of orthogonal design. The optimal extraction conditions of SALLE were: 4mL of salting-out solution with pH=4 and the sample pH=3. Under the optimum extraction and determination conditions, good responses for four PYRs were obtained in a range of 5-5000ng/mL, with linear coefficients greater than 0.998. The recoveries of the four PYRs ranged from 74% to 110%, with standard deviations ranging from 1.8% to 9.8%. The limits of detection based on a signal-to-noise ratio of 3 were between 1.5-60.6ng/mL. The method was applied to the determination of PYRs in urine, seawater and wastewater samples with a satisfactory result. The results demonstrated that this SALLE-GC-MS method was successfully applied to determine PYRs in high salinity and biological samples. SALLE avoided the need for the elimination of salinity and protein in the sample matrix, as well as clean-up of the extractant. Most of all, no centrifugation or any special apparatus are required, make this a promising method for rapid sample preparation procedure. Copyright © 2017 Elsevier B.V. All rights reserved.
Zgoła-Grześkowiak, Agnieszka
2010-03-12
Dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography with fluorescence detector was applied for the determination of alkylphenols and their short-chained ethoxylates in water samples. Development of DLLME procedure included optimisation of some important parameters such as kind and volume of extracting and dispersing solvents. Under optimised conditions 50 microL of trichloroethylene in 1.5 mL of acetone were rapidly injected into 5 mL of a water sample. After centrifuging the organic phase containing the analytes was taken for evaporation with a gentle nitrogen purge and reconstituted to 50 microL of acetonitrile. The aliquot of this solution was analysed with the use of HPLC. For octylphenol (OP) and octylphenol ethoxylates (OPEOs) linearity was satisfactory in the range 8-1000 microg L(-1) and for nonylphenol (NP) and nonylphenol ethoxylates (NPEOs) linearity was in the range from 50 to about 3000 microg L(-1). Limit of quantitation was 0.1 microg L(-1) for OP and OPEOs and 0.3 microg L(-1) for NP and NPEOs. Satisfactory recoveries between 66 and 79% were obtained for environmental samples. The results showed that DLLME is a simple, rapid and sensitive analytical method for the preconcentration of trace amounts of alkylphenols and their ethoxylates in environmental water samples. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Nasal nicotine solution: a potential aid to giving up smoking?
Russell, M A; Jarvis, M J; Feyerabend, C; Fernö, O
1983-01-01
A nasal solution was developed containing 2 mg nicotine for use as a kind of liquid snuff. Its absorption was studied in three subjects. An average peak of plasma nicotine concentrations of 86.9 nmol/l (14.1 ng/ml) was reached seven and a half minutes after taking the solution. This compared with an average peak of 158.4 nmol/l (25.7 ng/ml) one and a half minutes after completing (but seven and a half minutes after starting) a middle tar cigarette (1.4 mg nicotine) and an average peak of 52.4 nmol/l (8.5 ng/ml) after chewing nicotine gum (2 mg nicotine) for 30 minutes. The more rapid and efficient absorption of nicotine from the nasal nicotine solution than from nicotine chewing gum suggests that it might prove a useful aid to giving up smoking. Nasal nicotine solution might be particularly useful in smokers for whom the gum is less suitable on account of dentures or peptic ulcers or who experience nausea and dyspeptic symptoms from the gum. PMID:6402202
Chomchai, Chulathida; Sirisamut, Thanakorn; Silpasupagornwong, Uraiwan
2012-06-01
Gun bluing solution is commonly used to polish guns and prevent rusting. The authors report a case of a 2-year-old boy who inadvertently ingested approximately 15 ml of his father's Fox Gun Blue solution. The patient subsequently developed acidosis, hypotension, and coma. He died within four hours after ingestion. His plasma selenium level was 857 ng/ml. A brief review of other reported ingestion of gun bluing liquid in both adults and children is also included.
Xu, Xiongliang; Fu, Yao; Hu, Haiyan; Duan, Yourong; Zhang, Zhirong
2006-04-11
A rapid and effective isocratic chromatographic procedure was described in this paper for the determination of insulin entrapment efficiency (EE) in triblock copolymeric nanoparticles using reversed-phase high-performance liquid chromatography (RP-HPLC) with an ultraviolet/visible detector at low flow rate. The method has been developed on a Shimadzu Shim-pack VP-ODS column (150 mm x 4.6 mm, 5 microm, Chiyoda-Ku, Tokyo, Japan) using a mixture of 0.2 M sodium sulfate anhydrous solution adjusted to pH 2.3 with phosphoric acid and acetonitrile (73:27, v/v) as mobile phase at the flow rate of 0.8 ml min(-1) and a 214 nm detection. The method was validated in terms of selectivity, linearity, precision, accuracy, solution stability, limit of detection (LOD) and limit of quantification (LOQ). The calibration curve was linear in the concentration range of 2.0-500.0 microg ml(-1), and the limits of detection and quantitation were 8 and 20 ng, respectively. The mean recovery of insulin from spiked samples, in a concentration range of 8-100 microg ml(-1), was 98.96% (R.S.D.= 2.51%, n = 9). The intra- and inter-assay coefficients of variation were less than 2.24%. The proposed method has the advantages of simple pretreatment, rapid isolation, high specificity and precision, which can be used for direct analysis of insulin in commercially available raw materials, formulations of nanoparticles, and drug release as well as stability studies.
Xiong, Jing; Guo, Jianxin; Huang, Luosheng; Meng, Boyu; Ping, Qineng
2008-08-06
The purpose of this research is to evaluate the effect of self-micelle formation and incorporation of lipid in the formulation on absorption of ginsenosides Rg1 and Rb1 from intestinal tract in rats. Ginsenosides Rg1 and Rb1 were extracted from Panax notoginseng saponins (PNS). The critical micellar concentration (CMC) of PNS in deionzied water was determined to be 0.339 mg/ml. At normal physiological ionic strengths, PNS was salted out from the solution above the CMC. The particle size of the micelle grows as PNS concentration increases. By in situ injection to a closed loop of the rat jejunum, AUC0-6h obtained after administration of low concentration solution (12 mg/ml) was 3.61 times for ginsenoside Rg1 and 3.84-folds for ginsenoside Rb1 compared with high concentration solution (120 mg/ml). The release rate of ginsenosides in aqueous medium was too slow to complete in 24h, especially for Rb1. The data suggested that the self-micelle formation tendency in ginsenosides might prevent them from permeation or absorption through the cell membrane of gastrointestinal (GI) tract. To inhibit the formation of micelles, lipid was incorporated in the PNS formulation. The intraduodenal bioavailability in rats showed that the bioavailability was enhanced remarkably relative to the aqueous solution. AUC 0-infinity of ginsenoside Rg1 and Rb1 in the lipid-based formulation were 207.52+/-53.95 and 1961.72+/-686.60 microg ml(-1) h, compared with 7.87+/-2.85 and 148.58+/-36.73 microg ml(-1) h, respectively from its aqueous solution. These findings suggested a new strategy to increase the absorption of amphiphilic saponins.
Hedaya, Mohsen A; Thomas, Vidhya; Abdel-Hamid, Mohamed E; Kehinde, Elijah O; Phillips, Oludotun A
2017-01-01
Linezolid is the first approved oxazolidinone antibacterial agent, whereas PH027 is a novel compound of the same class that exhibits good in vitro antibacterial activity. The objective of this study was to develop an UPLC-MS/MS assay for the analysis of linezolid and PH027 in plasma and to apply the method for comparative pharmacokinetic and tissue distribution studies of both compounds. Plasma samples and calibrators were extracted with diethyl ether after addition of the internal standard solution. After evaporation of the ether layer, the residue was reconstituted in mobile phase and injected into UPLC-MS/MS. The mobile phase consisted of 2mM ammonium acetate buffer solution and acetonitrile (70:30) at a flow rate of 0.2ml/min. Separation was achieved using UPLC BEH C 18 column, and quantitative determination of the analytes was performed using multiple-reaction monitoring (MRM) scanning mode. The method was validated by analyzing quality control tissue homogenate samples, and was applied to analyze tissue homogenate samples obtained following IV injections of linezolid and PH027 in rabbits. The developed UPLC-MS/MS method was linear in the concentration range of 50-5000ng/ml. Validation of the method proved that the method's precision, selectivity and stability were all within the acceptable limits. Linezolid and PH027 concentrations were accurately determined in the quality control tissue homogenate samples, and analysis of samples obtained following IV administration of the two compounds showed that the tissue to plasma concentration ratio of PH027 was higher than that of linezolid probably due to its higher lipophilicity. The developed UPLC-MS/MS method for the analysis of linezolid and PH027 in rabbit's plasma can accurately determine the concentrations of these compounds in different tissues. Copyright © 2016 Elsevier B.V. All rights reserved.
Porosity characterization of biodegradable porous poly (L-lactic acid) electrospun nanofibers
NASA Astrophysics Data System (ADS)
Valipouri, Afsaneh; Gharehaghaji, Ali Akbar; Alirezazadeh, Azam; Ravandi, Seyed Abdolkarim Hosseini
2017-12-01
Poly-L lactic acid (PLLA) is one of the mostly used fibers in biomedical applications as a biodegradable and biocompatible material. Porosity and fiber diameter distribution are governing factors that determine the performance of nanofibers. Present work aims at investigating the process parameters that are affecting porosity and diameter distribution of PLLA nanofibers. PLLA nanofibers were fabricated through electrospinning method using the solution of PLLA polymer/dichloromethane (DCM). Nanofibers with various fiber diameter distribution and porosity were made by changing of process parameters such as spinning distance (5, 10 and 15 cm), voltage (11 and 15 kV), solution concentration (10, 11 and 12 wt%) and feeding rate (0.3, 0.4 and 0.7 ml h-1). Image processing techniques (with Matlab R2017), surface analysis (with Mountainsmap7) and diameter distribution analysis (with Measurement software) were used to examine surface morphology of samples. The results showed that the fiber diameter distribution becomes wider with increasing the applied voltage and reducing the spinning distance. In the other hand, coarse fibers possessed larger pores while having irregular and fewer pores in comparison to fine fibers. The most uniform nano-web with high porous nanofibers was attained by the choice of the process parameters at the voltage of 11 kV, spinning distance of 15 cm, feeding rate of 0.4 ml h-1 and solution concentration of 10 wt%.
Wyss, R; Bucheli, F
1988-02-26
A fully automated gradient high-performance liquid chromatographic method for the determination of isotretinoin, tretinoin and their 4-oxo metabolites in plasma was developed, using the column-switching technique. After dilution with an internal standard solution containing 20% acetonitrile, 0.5 ml of the sample was injected onto a precolumn (17 X 4.6 mm I.D.), filled with C18 Corasil 37-53 micron. Proteins and polar plasma components were washed out using 1% ammonium acetate-acetonitrile (9:1, v/v) as mobile phase 1. After valve switching, the retained components were transferred to the analytical column in the backflush mode, separated by gradient elution and detected at 360 nm by UV detection. Using two coupled reversed-phase columns (125 mm long), the separation of cis and trans isomers was possible, and all four compounds could be quantified down to 2 ng/ml of plasma. The inter-assay precision in the concentration range 20-100 ng/ml was between 1.0 and 4.7% for all compounds.
NASA Astrophysics Data System (ADS)
Tian, Fengling; Huang, Wei; Yang, Jidong; Li, Qin
In pH 3.25-3.35 Britton-Robinson (BR) buffer solution, albendazole (ABZ) could react with eosin Y (EY) to form a 1:1 ion-association complex, which not only results in the quenching of fluorescence, but also resulted in the great enhancement of resonance Rayleigh scattering (RRS) and frequency doubling scattering (FDS). Furthermore, a new RRS spectrum will appear, and the maximum RRS wavelength was located at about 356 nm. The detection limit for ABZ were 21.51 ng mL-1 for the fluorophotometry, 6.93 ng mL-1 for the RRS method and 12.89 ng mL-1 for the FDS method. Among them, the RRS method had the highest sensitivity. The experimental conditions were optimized and effects of coexisting substances were evaluated. Meanwhile, the influences of coexisting substances were tested. The methods have been successfully applied to the determination of ABZ in capsules and human urine samples. The composition and structure of the ion-association complex and the reaction mechanism were discussed.
Scott, Brittney R; Yang, Xiang; Geornaras, Ifigenia; Delmore, Robert J; Woerner, Dale R; Reagan, James O; Morgan, J Brad; Belk, Keith E
2015-11-01
Studies were conducted to evaluate the efficacy of a commercial blend of sulfuric acid and sodium sulfate (SSS) in reducing Salmonella on inoculated whole chilled chicken wings and to compare its efficacy to peroxyacetic acid (PAA) and cetylpyridinium chloride (CPC). Wings were spot inoculated (5 to 6 log CFU/ml of sample rinsate) with a five-strain mixture of novobiocin- and nalidixic acid-resistant Salmonella and then left untreated (control) or treated by immersing individual wings in 350 ml of antimicrobial solution. An initial study evaluated two treatment immersion times, 10 and 20 s, of SSS (pH 1.1) and compared cell recoveries following rinsing of treated samples with buffered peptone water or Dey/Engley neutralizing broth. In a second study, inoculated wings were treated with SSS (pH 1.1; 20 s), PAA (700 ppm, 20 s), or CPC (4,000 ppm, 10 s) and analyzed for survivors immediately after treatment (0 h) and after 24 h of aerobic storage at 4°C. Color and pH analyses were also conducted in the latter study. Recovery of Salmonella survivors following treatment with SSS (10 or 20 s) was not (P ≥ 0.05) affected by the type of cell recovery rinse solution (buffered peptone water or Dey/Engley neutralizing broth), but there was an effect (P < 0.05) of SSS treatment time. Immersion of samples for 10 or 20 s in SSS resulted in pathogen reductions of 0.8 to 0.9 and 1.1 to 1.2 log CFU/ml, respectively. Results of the second study showed that there was an interaction (P < 0.05) between antimicrobial type and storage time. Efficacy against Salmonella at 0 h increased in the order CPC , SSS , PAA; however, after 24 h of aerobic storage, pathogen counts of SSS- and PAA-treated wings did not differ (P ≥ 0.05). Overall, the results indicated that SSS applied at pH 1.1 for 20 s was an effective antimicrobial intervention to reduce Salmonella contamination on chicken wings.
Foster, M.D.
1953-01-01
Determination of free silica by the method proposed made possible the derivation of logical formulas for several specimens of montmorillonites for which the formulas could not be derived from the analyses alone. Other montmorillonites, for which logical formulas could be derived from their analyses, were found to contain small amounts of free silica or free alumina. Others were found to contain neither free silica nor free alumina. The method consists of the following steps: (1) digestion of 1 g of the specimen with 0.5 N NaOH solution in a covered platinum crucible or dish on a steam bath for 4 hrs, stirring the mixture at 30-min intervals, (2) filtration of the undissolved material, followed by washing several times with 1% NaOH solution, (3) neutralization of the filtrate with HCl, addition of 5 ml HCl in excess and determination of SiO and Al2O3 in the usual way and (4) calculation of the amount of free SiO2 or free Al2O3 if any and the amount of attack of the clay structure by the treatment from the ratio of SiO2 to Al2O3 dissolved and the ratio of SiO2 to Al2O3 obtained on analysis. Tests with 5% Na2CO3 solution, the reagent formerly used for the solution of free SiO2 in rocks and minerals, showed that solution of opal by this reagent is always fractional, never complete, no matter how small the amount present or how long the period of treatment. Re-treatment of the sample results in 90-95% solution if 10 mg or less of opal is present, but for larger amounts of opal the percentage dissolved decreases as the amount present increases. On the other hand, 75 ml of 0.5 N NaOH completely dissolves as much as 400 mg of opal in 4 hrs digestion in a covered platinum crucible or dish, on a steam bath. However, a weaker solution or a shorter period of digestion does not effect complete solution. The same amount (75 ml) of 0.5 N NaOH also dissolves 90 mg of cristobalite and 57 mg of quartz having a grain size of less than 2 microns. Use of NaOH also permits determination of the amount of alumina dissolved, and estimation of the extent to which the clay structure was attacked by the treatment. ?? 1953.
Lakshmi, Karunanidhi Santhana; Lakshmi, Sivasubramanian
2011-03-01
Simultaneous determination of valsartan and hydrochlorothiazide by the H-point standard additions method (HPSAM) and partial least squares (PLS) calibration is described. Absorbances at a pair of wavelengths, 216 and 228 nm, were monitored with the addition of standard solutions of valsartan. Results of applying HPSAM showed that valsartan and hydrochlorothiazide can be determined simultaneously at concentration ratios varying from 20:1 to 1:15 in a mixed sample. The proposed PLS method does not require chemical separation and spectral graphical procedures for quantitative resolution of mixtures containing the titled compounds. The calibration model was based on absorption spectra in the 200-350 nm range for 25 different mixtures of valsartan and hydrochlorothiazide. Calibration matrices contained 0.5-3 μg mL-1 of both valsartan and hydrochlorothiazide. The standard error of prediction (SEP) for valsartan and hydrochlorothiazide was 0.020 and 0.038 μg mL-1, respectively. Both proposed methods were successfully applied to the determination of valsartan and hydrochlorothiazide in several synthetic and real matrix samples.
Wood, Mark; Reader, Al; Nusstein, John; Beck, Mike; Padgett, David; Weaver, Joel
2005-06-01
The purpose of this prospective, randomized study was to compare the venous blood levels of lidocaine and heart rate changes after intraosseous and infiltration injections of 1.8 ml of 2% lidocaine with 1:100,000 epinephrine. Using a crossover design, 20 subjects randomly received an intraosseous and infiltration injection at two separate appointments. The heart rate was measured using a pulse oximeter. Venous blood samples were collected before the injections and at 2, 5, 10, 15, 20, 25, 30, 45, and 60 min after the injections. The blinded plasma samples were analyzed for lidocaine concentrations using high-performance liquid chromatography (HPLC). The intraosseous injection resulted in a statistically significant increase in heart rate, when compared to the infiltration injection, during solution deposition and for 2 min after the injection. The plasma levels of lidocaine were not statistically different for maxillary anterior intraosseous and infiltration injections when using 1.8 ml of 2% lidocaine with 1:100,000 epinephrine.
Runes, H B; Jenkins, J J; Field, J A
1999-08-01
Triadimefon, a fungicide, and ethofumesate, an herbicide, are commonly applied to turfgrass in the Pacific Northwest, resulting in foliar residues. A simple and rapid method was developed to determine triadimefon and ethofumesate concentrations from dislodgeable foliar residues on turfgrass. Turfgrass samples were washed, and wash water containing surfactant (a 0.126% solution) was collected for residue analysis. This analytical method utilizes a 25 mm C(8) Empore disk and in-vial elution to quantitatively determine triadimefon and ethofumesate in 170 mL aqueous samples. The analytes were eluted by placing the disk in a 2 mL autosampler vial with 980 microL of ethyl acetate and 20 microL of 2-chlorolepidine, the internal standard, for analysis by GC/MS. The method quantitation limits are 0.29 microg/L for ethofumesate and 0.59 microg/L for triadimefon. The method detection limits are 0.047 microg/L and 0.29 microg/L for ethofumesate and triadimefon, respectively. Concentrations of triadimefon and ethofumesate from dislodgeable foliar residues from a field study are reported.
Tagiri-Endo, Misako; Suzuki, Shigeru; Nakamura, Tomoyuki; Hatakeyama, Takashi; Kawamukai, Kazuo
2009-02-01
A simple and quick online solid-phase extraction (SPE) coupled to liquid chromatography (LC)/tandem mass spectrometry (MS/MS) for the determination of the five antibiotics (florfenicol, FF; lincomycin, LCM; oxytetracyclin, OTC; tylosin, TS; valnemulin, VLM) in swine wastewater has been developed. After filtration, aliquots (100 microl) of wastewater samples were directly injected to a column-switching LC system. Some matrix interference was removed by washing up SPE column with 0.2% formic acid solution and acetonitrile. Antibiotics eluted from SPE column were separated on analytical column by converting switching valve and were detected by MS/MS. Calibration curves using the method of standard addition had very good correlation coefficients (r > 0.99) in the range of 0.1 to 2 ng/ml. The intra-day precision of the method was less than 12% and the inter-day precision was between 6 to 17%. The detection limits were 0.01-0.1 ng/ml. When this method was applied to wastewater samples in swine facilities, four compounds (LCM, OTC, TS, and VLM) were detected.
Yones, Doaa A; Taher, Gamal A; Ibraheim, Zedan Z
2011-09-01
The present work evaluated the effects of alcoholic extracts of salvia (Salvia officinalis), thyme (Thymus vulgaris), and 2 pure compounds (thymol and menthol) on the viability of Echinococcus granulosus protoscolices in vitro. Four different concentrations of each extract (2,500, 1,500, 1,000, and 500 µg/ml) and 3 different concentrations each of thymol and menthol (50, 10, and 1 µg/ml) were used. Concentration of 2,500 µg/ml of both extracts showed a significant protoscolicidal activity on the 6th day. Complete loss of viability of protoscolices occurred with 500 µg/ml concentration of both extracts at day 6 and day 7 post-treatment (PT), respectively. Pure compounds, i.e., menthol and thymol, showed potent effects with 50 µg/ml concentration at day 2 and day 5 PT, respectively. These effects were compared with those of albendazole sulfoxide (800 µg/ml), a commonly used treatment drug for hydatidosis. Krebs-Ringer solution and the hydatid cystic fluid at a ratio of 4:1 was a good preservative solution which kept the protoscolices viable for 15 days.
Gref, Margareta C; Karp, Kjell H
2009-03-01
The single-sample Tc-diethylenetriamine penta-acetate (DTPA) clearance method by Christensen and Groth is recommended by the Radionuclides in Nephrourology Committee on Renal Clearance for use in adults with an estimated glomerular filtration rate (GFR) > or = 30 ml/min. The purpose of this study was to test a new Tc-DTPA single-sample low clearance formula for GFR lesser than 30 ml/min. Twenty-one adult patients (29 investigations) were included. Reference clearance was calculated with both Cr-EDTA and Tc-DTPA according to Brøchner-Mortensen with samples drawn between 3 and 24 h. Single-sample clearance was calculated from a 24 h sample using the low clearance formula(Equation is included in full-text article.) C(t) is the activity of the tracer in the plasma sample t minutes after the injection and Q0 is the injected amount. ECV is the extracellular volume in ml defined as the distribution volume of the tracer. ECV is estimated from the body surface area as ECV=8116.6xbody surface area-28.2. The mean difference between reference and Tc-DTPA single-sample clearance was -0.5 ml/min (SD 1.0 ml/min) for Tc-DTPA and -0.8 ml/min (SD 1.2 ml/min) for Cr-EDTA as reference clearance. In adult patients it is possible, even with GFR lesser than 30 ml/min, to get an accurate determination of Tc-DTPA plasma clearance from a single sample using the mean sojourn time approach. The blood sample should be obtained about 24 h after injection of the GFR tracer.
JahaniShoorab, Nahid; Ebrahimzadeh Zagami, Samira; Nahvi, Ali; Mazluom, Seyed Reza; Golmakani, Nahid; Talebi, Mahdi; Pabarja, Ferial
2015-01-01
Background Pain is one of the side effects of episiotomy. The virtual reality (VR) is a non-pharmacological method for pain relief. The purpose of this study was to determine the effect of using video glasses on pain reduction in primiparity women during episiotomy repair. Methods This clinical trial was conducted on 30 primiparous parturient women having labor at Omolbanin Hospital (Mashhad, Iran) during May-July 2012. Samples during episiotomy repair were randomly divided into two equal groups. The intervention group received the usual treatment with VR (video glasses and local infiltration 5 ml solution of lidocaine 2%) and the control group only received local infiltration (5 ml solution of lidocaine 2%). Pain was measured using the Numeric Pain Rating Scale (0-100 scale) before, during and after the episiotomy repair. Data were analyzed using Fisher’s exact test, Chi-square, Mann-Whitney and repeated measures ANOVA tests by SPSS 11.5 software. Results There were statistically significant differences between the pain score during episiotomy repair in both groups (P=0.038). Conclusion Virtual reality is an effective complementary non-pharmacological method to reduce pain during episiotomy repair. Trial Registration Number: IRCT138811063185N1. PMID:25999621
Geller, David E.; Flume, Patrick A.; Griffith, David C.; Morgan, Elizabeth; White, Dan; Loutit, Jeffery S.; Dudley, Michael N.
2011-01-01
The pharmacokinetics and tolerability of nebulized MP-376 (levofloxacin inhalation solution [Aeroquin]) were determined in cystic fibrosis (CF) subjects. Ten CF subjects received single 180-mg doses of two formulations of MP-376, followed by a multiple-dose phase of 240 mg once daily for 7 days. Serum and expectorated-sputum samples were assayed for levofloxacin content. Safety was evaluated following the single- and multiple-dose study phases. Nebulized MP-376 produced high concentrations of levofloxacin in sputum. The mean maximum plasma concentration (Cmax) ranged between 2,563 and 2,932 mg/liter for 180-mg doses of the 50- and 100-mg/ml formulations, respectively. After 7 days of dosing, the mean Cmax for the 240-mg dose was 4,691 mg/liter. The mean serum levofloxacin Cmax ranged between 0.95 and 1.28 for the 180-mg doses and was 1.71 for the 240-mg dose. MP-376 was well tolerated. Nebulized MP-376 produces high sputum and low serum levofloxacin concentrations. The pharmacokinetics, safety, and tolerability were similar for the two formulations. MP-376 240 mg (100 mg/ml) is being advanced into late-stage clinical development. PMID:21444699
Wyss, R; Bucheli, F
1997-10-24
A highly sensitive HPLC method with automated column switching was developed for the simultaneous determination of endogenous levels of 13-cis-retinoic acid (isotretinoin), all-trans-retinoic acid (tretinoin) and their 4-oxo metabolites in plasma samples from man, Cynomolgus monkey, rabbit, rat and mouse. Plasma (0.4 ml) was deproteinated by adding ethanol (1.5 ml) containing the internal standard acitretin. After centrifugation, 1.4 ml of the supernatant were directly injected onto the precolumn packed with LiChrospher 100 RP-18 (5 microm). 1.25% ammonium acetate and acetic acid-ethanol (8:2, v/v) was used as mobile phase during injection and 1% ammonium acetate and 2% acetic acid-ethanol (102:4, v/v) was added, on-line, to decrease the elution strength of the injection solution. After backflush purging of the precolumn, the retained components were transferred to the analytical column in the backflush mode, separated by gradient elution and detected at 360 nm. Two coupled Superspher 100 RP-18 endcapped columns (both 250x4 mm) were used for the separation, together with a mobile phase consisting of acetonitrile-water-10% ammonium acetate-acetic acid: (A) 600:300:60:10 (v/v/v/v), (B) 950:20:5:20 (v/v/v/v), and (C) 990:5:0:5 (v/v/v/v). The method was linear in the range 0.3-100 ng/ml, at least, with a quantification limit of 0.3 ng/ml. The mean recoveries from human plasma were 93.2%-94.4% and the mean inter-assay precision was 2.8%-3.2% (range 0.3-100 ng/ml). Similar results were obtained for animal plasma. The analytes were found to be stable in the plasma of all investigated species stored at -20 degrees C for 4.3 months and at -80 degrees C for 9 months, at least. At this temperature, human plasma samples were even stable for 2 years. The method was successfully applied to more than 6000 human and 1000 animal plasma samples from clinical and toxicokinetic studies. Endogenous levels determined in control patients and pregnant women were similar to published data from volunteers.
Ruggera, P S; Fahy, G M
1990-10-01
Devitrification (ice formation during warming) is one of the primary obstacles to successful organ vitrification (solidification without ice formation). The only feasible approach to overcoming either devitrification or its damaging effects in a large organ appears at present to be the use of some form of electromagnetic heating (EH) to achieve the required high heating rates. One complication of EH in this application is the need for warming within a steel pressure vessel. We have previously reported that resonant radiofrequency (RF) helical coils provide very uniform heating at ambient temperatures and low heating rates and can be modified for coaxial power transmission, which is necessary if only one cable is to penetrate through the wall of the pressure vessel. We now report our initial studies using a modified helical coil, high RF input power, and cryogenic aqueous cryoprotectant solutions [60% (w/v) solution of 4.37 M dimethylsulfoxide and 4.37 M acetamide in water and 50% (w/w) 1,2-propanediol]. We also describe the electronic equipment required for this type of research. Temperatures were monitored during high-power conditions with Luxtron fiberoptic probes. Thermometry was complicated by the use of catheters needed for probe insertion and guidance. The highest heating rates we observed using catheters occurred at temperatures ranging from about -70 to -40 degrees C, the temperature zone where devitrification usually appears in unstable solutions during slow warming. We find that in this range we can achieve measured heating rates of approximately 300 degrees C/min in 30- to 130-ml samples using 200 to 700 W of RF power without overheating the sample at any point. However, energy conservation calculations imply that our measured peak heating rates may be considerably higher than the true heating rates occurring in the bulk of our solutions. We were able to estimate the overall true heating rates, obtaining an average value of about 20 degrees C/min/100 W/100 ml, which implies a heating efficiency close to 100%. It appears that it should be possible to warm vitrified rabbit kidneys rapidly enough under high-pressure conditions to protect them from devitrification.
Balcerek, Maria; Pielech-Przybylska, Katarzyna; Patelski, Piotr; Dziekońska-Kubczak, Urszula; Jusel, Tomaš
2017-05-01
This study investigates the effect of treatment with activated carbon and other adsorbents on the chemical composition and organoleptics of a barley malt-based agricultural distillate. Contact with activated carbon is one of the methods by which the quality of raw distillates and spirit beverages can be improved. Samples placed in contact with 1 g activated carbon (SpiritFerm) per 100 ml distillate with ethanol content of 50% v/v for 1 h showed the largest reductions in the concentrations of most volatile compounds (aldehydes, alcohols, esters). Increasing the dose of adsorbent to over 1 g 100 ml -1 did not improve the purity of the agricultural distillate significantly. Of the tested compounds, acetaldehyde and methanol showed the lowest adsorption on activated carbon. The lowest concentrations of these congeners (expressed in mg l -1 alcohol 100% v/v) were measured in solutions with ethanol contents of 70-80% v/v, while solutions with an alcoholic strength by volume of 40% did not show statistically significant decreases in these compounds in relation the control sample. The reductions in volatile compounds were compared with those for other adsorbents based on silica or activated carbon and silica. An interesting alternative to activated carbon was found to be an adsorbent prepared from activated carbon and silica (Spiricol). Treatment with this adsorbent produced distillate with the lowest concentrations of acetaldehyde and isovaleraldehyde, and led to the greatest improvement in its organoleptics.
Hagiwara, Kenta; Inui, Tetsuo; Koike, Yuya; Aizawa, Mamoru; Nakamura, Toshihiro
2015-03-01
A rapid and simple method using wavelength-dispersive X-ray fluorescence (WDXRF) spectrometry after in situ solid-phase extraction (SPE) was developed for the speciation and evaluation of the concentration of inorganic arsenic (As) in drinking water. The method involves the simultaneous collection of As(III) and As(V) using 13 mm ϕ SPE miniature disks. The removal of Pb(2+) from the sample water was first conducted to avoid the overlapping PbLα and AsKα spectra on the XRF spectrum. To this end, a 50 mL aqueous sample (pH 5-9) was passed through an iminodiacetate chelating disk. The filtrate was adjusted to pH 2-3 with HCl, and then ammonium pyrrolidine dithiocarbamate solution was added. The solution was passed through a hydrophilic polytetrafluoroethylene filter placed on a Zr and Ca loaded cation-exchange disk at a flow rate of 12.5 mL min(-1) to separate As(III)-pyrrolidine dithiocarbamate complex and As(V). Each SPE disk was affixed to an acrylic plate using adhesive cellophane tape, and then examined by WDXRF spectrometry. The detection limits of As(III) and As(V) were 0.8 and 0.6 μg L(-1), respectively. The proposed method was successfully applied to screening for As speciation and concentration evaluation in spring water and well water. Copyright © 2014 Elsevier B.V. All rights reserved.
Kuklya, Andriy; Uteschil, Florian; Kerpen, Klaus; Marks, Robert; Telgheder, Ursula
2014-03-01
The feasibility of an electrospray coupled with a (63)Ni-differential ion mobility spectrometer (DMS) for the analysis of water samples was proven on examples of 2-hexanone, fluoroacetamide, l-nicotine and 1-phenyl-2-thiourea water solutions. The model substances were selected in order to cover the vapor pressure range of 0.3-1467 Pa. To reduce the inline humidity, which demonstrates a strong influence on the analyte compensation voltage, two units with a desolvation region lengths of 15.5 and 7 mm were examined. The counter gas (heated to 100 °C nitrogen) with flow rates of 100 mL min(-1) and 30 mL min(-1) for short and long desolvation units, respectively, was essential for the efficient reduction of humidity. The reduction of water content in the carrier gas to 2.2-2.4 g m(-3) and to 1.8-2.0 g m(-3) for the short and long desolvation unit, respectively, was achieved at an electrospray flow rate of 1000 nL min(-1). With this adjusted experimental setup, the detection of model substances in the water solutions, in the range of 0.1-50 mg L(-1), was performed. No correlation between the vapor pressure and signal area was observed. The high stability of the inline humidity, and the correspondingly stable carrier gas flow rate, were found to be essential for an acceptable reproducibility. © 2013 Elsevier B.V. All rights reserved.
Maximum likelihood orientation estimation of 1-D patterns in Laguerre-Gauss subspaces.
Di Claudio, Elio D; Jacovitti, Giovanni; Laurenti, Alberto
2010-05-01
A method for measuring the orientation of linear (1-D) patterns, based on a local expansion with Laguerre-Gauss circular harmonic (LG-CH) functions, is presented. It lies on the property that the polar separable LG-CH functions span the same space as the 2-D Cartesian separable Hermite-Gauss (2-D HG) functions. Exploiting the simple steerability of the LG-CH functions and the peculiar block-linear relationship among the two expansion coefficients sets, maximum likelihood (ML) estimates of orientation and cross section parameters of 1-D patterns are obtained projecting them in a proper subspace of the 2-D HG family. It is shown in this paper that the conditional ML solution, derived by elimination of the cross section parameters, surprisingly yields the same asymptotic accuracy as the ML solution for known cross section parameters. The accuracy of the conditional ML estimator is compared to the one of state of art solutions on a theoretical basis and via simulation trials. A thorough proof of the key relationship between the LG-CH and the 2-D HG expansions is also provided.
Cabrera, J; Mancuso, M; Cabrera-Fránquiz, F; Limiñana, J; Díez, A
2011-01-01
To determine whether a mixture for intravenous perfusion containing tramadol (5 mg/ml), ranitidine (1.5 mg/ml), ketorolac (1.5 mg/ml) and metoclopramide (0.5 mg/ml) in a 0.9% sodium chlorides solution is compatible and stable at room temperature during a 48-hour period. We tested the mixture for stability using the HPLC technique (high performance liquid chromatography), with parallel visual assessments of any changes in colour, appearance of precipitate or phase separation indicating incompatibilities between the components. At the end of the trial, chromatography data showed a mean metoclopramide concentration between 100% and 105% of the initial level, while concentrations of tramadol, ketorolac and ranitidine were between 99% and 102% of initial levels. There was no evidence of incompatibility between the drugs at any time during the study period. The combination is stable as a solution and its components are physically and chemically compatible in the concentrations used in the study, during at least 48 hours at room temperature. Copyright © 2008 SEFH. Published by Elsevier Espana. All rights reserved.
The effect of air bubbles on rabbit blood brain barrier.
Hjelde, A; Bolstad, G; Brubakk, A O
2002-01-01
Several investigators have claimed that the blood brain barrier (BBB) may be broken by circulating bubbles, resulting in brain tissue edema. The aim of this study was to examine the effect of air bubbles on the permeability of BBB. Three groups of 6 rabbits were infused an isoosmotic solution of NaCl w/macrodex and 1% Tween. The solution was saturated with air bubbles and infused at rates of 50-100 ml hr(-1), a total of 1.6, 3.3, or 6.6 ml in each group, respectively. Two groups, each consisting of 6 rabbits, served as controls; one was infused by a degassed isoosmotic NaCl solution and one was sham-operated. All animals were left for 30 min before they were sacrificed. Specific gravity of brain tissue samples was determined using a brombenzene/kerosene gradient column, where a decrease in specific gravity indicates local brain edema. Specific gravity was significantly lower for left (P = 0.037) and right (P = 0.012) hemisphere white matter and left (P = 0.0015) and right (P = 0.002) hemisphere gray matter for the bubble-infused animals compared to the sham-operated ones. Infusion of degassed NaCl solution alone affected white left (P= 0.011) and right (P= 0.013), but not gray matter of both hemispheres. We speculate that insufficient degassing of the fluid may cause the effect of NaCl solution on the BBB of the white matter, indicating that the vessels of the white matter are more sensitive to gas bubbles than gray matter. Increasing the number of infused bubbles had no further impact on the development of cerebral edema, indicating that a threshold value was reached already at the lowest concentration of bubbles.
Çeliksular, M Cem; Saraçoğlu, Ayten; Yentür, Ercüment
2016-06-01
The effects of oral carbohydrate solutions, ingested 2 h prior to operation, on stress response were studied in patients undergoing general or epidural anaesthesia. The study was performed on 80 ASA I-II adult patients undergoing elective total hip replacement, which were randomized to four groups (n=20). Group G patients undergoing general anaesthesia fasted for 8 h preoperatively; Group GN patients undergoing general anaesthesia drank oral carbohydrate solutions preoperatively; Group E patients undergoing epidural anaesthesia fasted for 8 h and Group EN patients undergoing epidural anaesthesia drank oral carbohydrate solutions preoperatively. Groups GN and EN drank 800 mL of 12.5% oral carbohydrate solution at 24:00 preoperatively and 400 mL 2 h before the operation. Blood samples were taken for measurements of glucose, insulin, cortisol and IL-6 levels. The effect of preoperative oral carbohydrate ingestion on blood glucose levels was not significant. Insulin levels 24 h prior to surgery were similar; however, insulin levels measured just before surgery were 2-3 times higher in groups GN and EN than in groups G and E. Insulin levels at the 24(th) postoperative hour in epidural groups were increased compared to those at basal levels, although general anaesthesia groups showed a decrease. From these measurements, only the change in Group EN was statistically significant (p<0.05). Plasma cortisol levels at the 2(nd) peroperative hour were higher in epidural groups than in general anaesthesia groups. Both anaesthesia techniques did not have an effect on IL-6 levels. We concluded that epidural anaesthesia suppressed stress response, although preoperative oral carbohydrate nutrition did not reveal a significant effect on surgical stress response.
Cobo Molinos, Antonio; Abriouel, Hikmate; Ben Omar, Nabil; Valdivia, Eva; Lucas López, Rosario; Maqueda, Mercedes; Cañamero, Magdalena Martínez; Gálvez, Antonio
2005-01-01
The effect of immersion solutions containing enterocin AS-48 alone or in combination with chemical preservatives on survival and proliferation of Listeria monocytogenes CECT 4032 inoculated on fresh alfalfa sprouts, soybean sprouts, and green asparagus was tested. Immersion treatments (5 min at room temperature) with AS-48 solutions (25 μg/ml) reduced listeria counts of artificially contaminated alfalfa and soybean sprouts by approximately 2.0 to 2.4 log CFU/g compared to a control immersion treatment in distilled water. The same bacteriocin immersion treatment applied on green asparagus had a very limited effect. During storage of vegetable samples treated with immersion solutions of 12.5 and 25 μg of AS-48/ml, viable listeria counts were reduced below detection limits at days 1 to 7 for alfalfa and soybean sprouts at 6 and 15°C, as well as green asparagus at 15°C. Only a limited inhibition of listeria proliferation was detected during storage of bacteriocin-treated alfalfa sprouts and green asparagus at 22°C. Treatment with solutions containing AS-48 plus lactic acid, sodium lactate, sodium nitrite, sodium nitrate, trisodium phosphate, trisodium trimetaphosphate, sodium thiosulphate, n-propyl p-hydroxybenzoate, p-hydoxybenzoic acid methyl ester, hexadecylpyridinium chloride, peracetic acid, or sodium hypochlorite reduced viable counts of listeria below detection limits (by approximately 2.6 to 2.7 log CFU/g) upon application of the immersion treatment and/or further storage for 24 h, depending of the chemical preservative concentration. Significant increases of antimicrobial activity were also detected for AS-48 plus potassium permanganate and in some combinations with acetic acid, citric acid, sodium propionate, and potassium sorbate. PMID:16332751
Isehunwa, G O; Yusuf, I O; Alada, A Ar
2017-03-06
This study investigated the effects of exposure to petrol on blood glucose, liver and muscle glycogen levels in the common African toad Bufo regularis. A total of 126 adult toads of either sex weighing between 70-100g were used for this study. The experiment was divided into three phases. The phase 1 experiment the acute toxicity test consisted of animals divided into six groups of 10 toads per group and were exposed to water (H2O), H2O + Tween 80, 2ml/l, 3ml/l, 5ml/l, and 10ml/l of petrol respectively for 96 hours using the static renewal bioassay system. In the Phase 2 experiment, the animals were exposed to H2O, H2O + Tween 80, 0.14ml/l, 0.3ml/l, 0.6ml/l, and 1.13ml/l of petrol respectively for 3 days; while in phase 3 experiment they were exposed to petrol solutions for 14 days. After the various exposures, the blood glucose, liver and muscle glycogen contents were determined using standard methods. The results of the study showed that the median lethal concentration of petrol (96 hours LC50) was 4.5ml/l and sub-lethal concentration of petrol caused mortality of animals. Exposure to petrol solutions for 3 days had no significant effect on blood glucose level of the animals but caused significant decrease in the liver and muscle glycogen levels at high concentrations. In the animals exposed to petrol solutions for 14 days, there was a significant increase in glucose levels and significant reduction in liver and muscle glycogen levels at high concentrations when compared with the control. The results show that sub-lethal concentrations of petrol can cause mortality of animals, hyperglycemia and reduction in liver and muscle glycogen levels. The effects of petrol exposure on carbohydrate metabolism depend on the concentration and duration of exposure.
Measurements of atmospheric nitrous acid and nitric acid
NASA Astrophysics Data System (ADS)
Huang, Gu; Zhou, Xianliang; Deng, Guohong; Qiao, Huancheng; Civerolo, Kevin
A highly sensitive technique for the measurement of atmospheric HONO and HNO 3 is reported. The technique is based on aqueous scrubbing using two coil samplers, followed by conversion of HNO 3 to nitrite, derivatization of nitrite to a highly light-absorbing azo dye with sulfanilamide (SA) and N-(1-naphthyl) ethylenediamine (NED), and high performance liquid chromatography (HPLC) analysis. HNO 3 concentration was obtained by the difference of the two channels. Two scrubbing solutions were used for sampling the two species: a 1-mM phosphate buffer solution (pH 7) for the measurement of HONO and a 180 mM NH 4Cl/NH 3 buffer solution (pH 8.5) for the measurement of HONO+HNO 3. The scrubbing solution flow rate was 0.24 ml min -1 and the gas sampling flow rate was 2 l min -1. HNO 3 in the NH 4Cl/NH 3 buffer solution was quantitatively reduced to nitrite along an on-line 0.8-cm Cd reductor column. Nitrite in both channels was derivatized with 2 mM SA and 0.2 mM NED in 25 mM HCl. Quantitative derivatization was achieved within 5 min at 55°C. The azo dye derivative was then separated from the SA/NED reagent by reversed-phase HPLC and detected with a UV-vis detector at 540 nm. With an on-line SEP-PAK C-18 cartridge for the reagent purification, the method detection limit is estimated to be better than 1 pptv for HONO and about 20 pptv for HNO 3. The sample integration time was about 2 min and the sampling frequency is every 10 min. Data collected in downtown Albany and Whiteface Mountain, NY, are shown as examples of applications of this technique in both urban and remote clean environments.
NASA Astrophysics Data System (ADS)
Bizzi, Cezar A.; Barin, Juliano S.; Garcia, Edivaldo E.; Nóbrega, Joaquim A.; Dressler, Valderi L.; Flores, Erico M. M.
2011-05-01
The feasibility of using diluted HNO 3 solutions under oxygen pressure for decomposition of whole and non-fat milk powders and whey powder samples has been evaluated. Digestion efficiency was evaluated by determining the carbon content in solution (digests) and the determination of Ca, Cd, Cu, Fe, K, Mg, Mn, Mo, Na, Pb and Zn was performed by inductively coupled plasma optical emission spectrometry and Hg by chemical vapor generation coupled to inductively coupled plasma mass spectrometry. Samples (up to 500 mg) were digested using HNO 3 solutions (1 to 14 mol L - 1 ) and the effect of oxygen pressure was evaluated between 2.5 and 20 bar. It was possible to perform the digestion of 500 mg of milk powder using 2 mol L - 1 HNO 3 with oxygen pressure ranging from 7.5 to 20 bar with resultant carbon content in digests lower than 1700 mg L - 1 . Using optimized conditions, less than 0.86 mL of concentrated nitric acid (14 mol L - 1 ) was enough to digest 500 mg of sample. The accuracy was evaluated by determination of metal concentrations in certified reference materials, which presented an agreement better than 95% (Student's t test, P < 0.05) for all the analytes.
Removal of lead from aqueous solutions using Cassia grandis seed gum-graft-poly(methylmethacrylate).
Singh, Vandana; Tiwari, Stuti; Sharma, Ajit Kumar; Sanghi, Rashmi
2007-12-15
Using persulfate/ascorbic acid redox system, a series of Cassia grandis seed gum-graft-poly(methylmethacrylate) samples were synthesized. The copolymer samples were evaluated for lead(II) removal from the aqueous solutions where the sorption capacities were found proportional to the grafting extent. The conditions for the sorption were optimized using copolymer sample of highest percent grafting. The sorption was found pH and concentration dependent, pH 2.0 being the optimum value. Adsorption of lead by the grafted seed gum followed a pseudo-second-order kinetics with a rate constant of 4.64 x 10(-5) g/mg/min. The equilibrium data followed the Langmuir isotherm model with maximum sorption capacity of 126.58 mg/g. The influence of electrolytes NaCl, Na(2)SO(4) on lead uptake was also studied. Desorption with 2 N HCl could elute 76% of the lead ions from the lead-loaded copolymer. The regeneration experiments revealed that the copolymer could be successfully reused for at least four cycles though there was a successive loss in lead sorption capacity with every cycle. The adsorbent was also evaluated for Pb(II) removal from battery waste-water containing 2166 mg/L Pb(II). From 1000 times diluted waste water, 86.1% Pb(II) could be removed using 0.05 g/20 ml adsorbent dose, while 0.5 g/20 ml adsorbent dose was capable of removing 60.29% Pb from 10 times diluted waste water. Optimum Pb(II) binding under highly acidic conditions indicated that there was a significant contribution of nonelectrostatic interactions in the adsorption process. A possible mechanism for the adsorption has been discussed.
Immunoaffinity centrifugal precipitation chromatography.
Qi, Lin; Ito, Yoichiro
2007-06-01
Purification of proteins based on immunoaffinity has been performed using a solid support coated with antibody against the target proteins. The method requires immobilizing the antibody onto the solid support using protein A or G, and has a risk of adsorptive loss of target proteins onto the solid support. Centrifugal precipitation chromatography has been successfully used to purify enzymes, such as ketosteroid isomerase and hyaluronidase without the use of solid support. The purpose of this study is to demonstrate that immunoaffinity centrifugal precipitation chromatography is capable of isolating an antigen by exploiting antigen-antibody binding. The separation was initiated by filling both channels with 40% saturated ammonium sulfate (AS) of pH 4-4.5 followed by loading 20 microl of human plasma (National Institutes of Health blood bank) mixed with 2 mg of rabbit anti-HSA (human serum protein) antibody (Sigma). Then, the sample channel was eluted with water at 0.03 ml/min and AS channel with 40% AS solution of pH 4-4.5 at 1 ml/min until all non-binding components were eluted. Then, the releasing reagent (50% AS solution containing 0.5 M glycine and 10% ammonium hydroxide at pH 10) was introduced through the AS channel to release the target protein (HSA). The retained antibody was recovered by eluting the sample channel with water at 1 ml/min. A hollow fiber membrane device at the outlet (MicroKros, Spectrum, New Brunswick, NJ, USA) was provided on-line dialysis of the eluent before fractions were collected, so that the fractions could be analyzed by SDS-PAGE (sodium dodecyl sulfate - polyacrylamide gel electrophoresis) without further dialysis. The current method does not require immobilizing the antibody onto a matrix, which is used by the conventional immunoaffinity chromatography. This method ensures full recovery of the antigen and antibody, and it may be applied to purification of other proteins.
Yilmaz, Vedat; Yilmaz, Hayriye; Arslan, Zikri; Leszczynski, Jerzy
2016-01-01
A novel Cd(II)-imprinted polymer was prepared with chemical immobilization approach by using N-methacryloyl-L-histidine as a vinylated chelating agent for on-line solid phase extraction of Cd(II) for determination by inductively coupled plasma mass spectrometry. Cd(II)-monomer complex was synthesized and copolymerized via bulk polymerization method in the presence of ethyleneglycoldimethacrylate cross-linker. The resulting polymer was leached with 1.0 mol L−1 HNO3 to generate the cavities in the polymer for Cd(II) ions. The experimental conditions, including load pH, solution flow rate, and eluent concentration for effective sorption of Cd(II) were optimized using a minicolumn of the imprinted polymer. A volume of 5.0 mL sample 5 μg L−1 Cd(II) solution at pH 6.5 was loaded onto the column at 2.0 mL min−1 by using a sequential injection system (FIALab 3200) followed by elution with 1.0 mL of 0.75 mol L−1 HNO3. The relative selectivity coefficients of the imprinted polymer for Cd(II) were 38.5, 3.5, 3.0, 2.5 and 6.0 in the presence of Cu(II), Ni(II), Zn(II), Co(II) and Pb(II), respectively. Computational calculations revealed that the selectivity of the imprinted polymer was mediated by the stability of Cd(II)-N-methacryloyl-L-histidine complex which was far more stable than those of commonly used monomers, such as 4-vinyl pyridine, methacrylic acid and vinylimidazole. The detection limit (3s) and relative standard deviation (%) were found to be 0.004 μg L−1 and 3.2%, respectively. The method was validated by analysis of seawater certified reference material (CASS-4) and successfully applied to the determination of Cd(II) in coastal seawater and estuarine water samples. PMID:28239183
Survival of Listeria monocytogenes in vanilla-flavored soy and dairy products stored at 8 degrees C.
Tipparaju, Sireesha; Ravishankar, Sadhana; Slade, Peter J
2004-02-01
The survival of Listeria monocytogenes V37 in vanilla-flavored yogurt (low-fat and nonfat) and soy milk (low-fat and Plus) stored at 8 degrees C for 31 days was investigated. Commercial samples of yogurt and soy milk were used. These samples were inoculated with either 10(4) or 10(7) CFU of L. monocytogenes per ml. Sampling was carried out every 3 to 4 days initially and was then carried out weekly, for a total storage time of 31 days. Each time a sample was collected, the pH of the sample was measured. After 31 days, low-fat plain, low-fat vanilla, and nonfat plain yogurt samples inoculated with 10(4) CFU/ml showed 2.5-log reductions in viable cell populations, and nonfat vanilla yogurt showed a 3.5-log reduction. For yogurt inoculated with 10(7) CFU/ml, reductions of 2.5 log CFU/ml were observed for plain low-fat and nonfat yogurts, and reductions of 5 log CFU/ml were observed for vanilla-flavored low-fat and nonfat yogurts. In vanilla-flavored and plain low-fat and Plus soy milk samples, cell counts increased from 10(4) and 10(7) CFU/ml to 10(9) CFU/ml at 7 and 3 days of storage, respectively, at 8 degrees C. Coagulation in soy milk samples was observed when the cell population reached 10(9) CFU/ml. In soy milk, the L. monocytogenes population did not change for up to 31 days. Vanillin had an inhibitory effect on L. monocytogenes in yogurt but not in soy milk.
A High Performance Impedance-based Platform for Evaporation Rate Detection.
Chou, Wei-Lung; Lee, Pee-Yew; Chen, Cheng-You; Lin, Yu-Hsin; Lin, Yung-Sheng
2016-10-17
This paper describes the method of a novel impedance-based platform for the detection of the evaporation rate. The model compound hyaluronic acid was employed here for demonstration purposes. Multiple evaporation tests on the model compound as a humectant with various concentrations in solutions were conducted for comparison purposes. A conventional weight loss approach is known as the most straightforward, but time-consuming, measurement technique for evaporation rate detection. Yet, a clear disadvantage is that a large volume of sample is required and multiple sample tests cannot be conducted at the same time. For the first time in literature, an electrical impedance sensing chip is successfully applied to a real-time evaporation investigation in a time sharing, continuous and automatic manner. Moreover, as little as 0.5 ml of test samples is required in this impedance-based apparatus, and a large impedance variation is demonstrated among various dilute solutions. The proposed high-sensitivity and fast-response impedance sensing system is found to outperform a conventional weight loss approach in terms of evaporation rate detection.
Ghamari, Farhad; Bahrami, Abdulrahman; Yamini, Yadollah; Shahna, Farshid Ghorbani; Moghimbeigi, Abbas
2016-01-01
For the first time, hollow-fiber liquid-phase microextraction combined with high-performance liquid chromatography–ultraviolet was used to extract trans,trans-muconic acid, in urine samples of workers who had been exposed to benzene. The parameters affecting the metabolite extraction were optimized as follows: the volume of sample solution was 11 mL with pH 2, liquid membrane containing dihexyl ether as the supporter, 15% (w/v) of trioctylphosphine oxide as the carrier, the time of extraction was 120 minutes, and stirring rate was 500 rpm. Organic phase impregnated in the pores of a hollow fiber was extracted into 24 µL solution of 0.05 mol L−1 Na2CO3 located inside the lumen of the fiber. Under optimized conditions, a high enrichment factor of 153–182 folds, relative recovery of 83%–92%, and detection limit of 0.001 µg mL−1 were obtained. The method was successfully applied to the analysis of ttMA in real urine samples. PMID:27660405
Elbashir, Ahmed B; Abdelbagi, Azhari O; Hammad, Ahmed M A; Elzorgani, Gafar A; Laing, Mark D
2015-03-01
Ninety-six human blood samples were collected from six locations that represent areas of intensive pesticide use in Sudan, which included irrigated cotton schemes (Wad Medani, Hasaheesa, Elmanagil, and Elfaw) and sugarcane schemes (Kenana and Gunaid). Blood samples were analyzed for organochlorine pesticide residues by gas liquid chromatography (GLC) equipped with an electron capture detector (ECD). Residues of p,p'-dichlorodiphenyldichloroethylene (DDE), heptachlor epoxide, γ-HCH, and dieldrin were detected in blood from all locations surveyed. Aldrin was not detected in any of the samples analyzed, probably due to its conversion to dieldrin. The levels of total organochlorine burden detected were higher in the blood from people in the irrigated cotton schemes (mean 261 ng ml(-1), range 38-641 ng ml(-1)) than in the blood of people from the irrigated sugarcane schemes (mean 204 ng ml(-1), range 59-365 ng ml(-1)). The highest levels of heptachlor epoxide (170 ng ml(-1)) and γ-HCH (92 ng ml(-1)) were observed in blood samples from Hasaheesa, while the highest levels of DDE (618 ng ml(-1)) and dieldrin (82 ng ml(-1)) were observed in blood samples from Wad Medani and Kenana, respectively. The organochlorine levels in blood samples seemed to decrease with increasing distance from the old irrigated cotton schemes (Wad Medani, Hasaheesa, and Elmanagil) where the heavy application of these pesticides took place historically.
Formal Verification of Complex Systems based on SysML Functional Requirements
2014-12-23
Formal Verification of Complex Systems based on SysML Functional Requirements Hoda Mehrpouyan1, Irem Y. Tumer2, Chris Hoyle2, Dimitra Giannakopoulou3...requirements for design of complex engineered systems. The proposed ap- proach combines a SysML modeling approach to document and structure safety requirements...methods and tools to support the integration of safety into the design solution. 2.1. SysML for Complex Engineered Systems Traditional methods and tools
NASA Astrophysics Data System (ADS)
Mousavi, M.; Kompany, A.; Shahtahmasebi, N.; Bagheri-Mohagheghi, M.-M.
2013-08-01
Vanadium oxide thin films were grown on glass substrates using spray pyrolysis technique. The effects of substrate temperature, vanadium concentration in the initial solution and the solution spray rate on the nanostructural and the electrochromic properties of deposited films are investigated. Characterization and the electrochromic measurements were carried out using X-ray diffraction, scanning electron microscopy and cyclic voltammogram. XRD patterns showed that the prepared films have polycrystalline structure and are mostly mixed phases of orthorhombic α-V2O5 along with minor β-V2O5 and V4O9 tetragonal structures. The preferred orientation of the deposited films was found to be along [101] plane. The cyclic voltammogram results obtained for different samples showed that only the films with 0.2 M solution concentration, 5 ml/min solution spray rate and 450°C substrate temperature exhibit two-step electrochromic properties. The results show a correlation between cycle voltammogram, morphology and resistance of the films.
Utilization of hydroxypropyl carboxymethyl cellulose in synthesis of silver nanoparticles.
Abdel-Halim, E S; Alanazi, Humaid H; Al-Deyab, Salem S
2015-04-01
Hydroxypropyl carboxymethyl cellulose samples having varying degrees of substitution and varying degrees of polymerization were used to reduce silver nitrate to silver nanoparticles. UV spectral analysis of silver nanoparticles colloidal solution reveal that increasing the pH of the reduction solution leads to improvement in the intensity of the absorption band for silver nanoparticles, to be maximum at pH 11. The absorption peak intensity also enhanced upon prolonging the reaction duration up to 60 min. The conversion of silver ions to metallic silver nanoparticles was found to be temperature-dependent and maximum transformation occurs at 60 °C. The reduction efficiency of hydroxypropyl carboxymethyl cellulose was found to be affected by its degree of polymerization. Colloidal solutions of silver nanoparticles having concentration up to 1000 ppm can be prepared upon fixing the ratio between silver nitrate and hydroxypropyl carboxymethyl cellulose at 0.017-0.3g per each 100ml of the reduction solution. Copyright © 2015 Elsevier B.V. All rights reserved.
Gehlen, Heidrun; Bradaric, Zrinkja
2013-01-01
The evaluation of plasma ACTH and the dexamethasone suppression test are considered the methods of choice to evaluate the course of therapy of pituitary pars intermedia dysfunction (PPID). Sampling protocols as well as vacutainers for analysis differ between the laboratories. To evaluate the reproducability of plasma ACTH measurement between four different laboratories (A, B, C, D) in Germany as well as within the laboratories themselves, ten horses with previously diagnosed PPID and four healthy horses were sampled and analyzed. Each laboratory received two differently labeled samples of each horse which had been drawn at the same time (blinded samples). Sampling was performed in the morning at the same time. The sampling vacutainers (with and without addition of coagulation and proteinase inhibitors) and postage of the samples was performed according to laboratory standards. In one laboratory the influence of the time of centrifugation (immediately after taking blood versus after one hour) was determined. The samples were processed and analyzed according to laboratory protocols. Determination of ACTH levels was performed using chemiluminescence immunoassay. In total 132 blood samples were analyzed. The results of doubled blood samples of the same horse showed a standard deviation ranging from +/- 6 to +/- 27 pg/ml within the laboratories (Ø 19,29 pg/ml). The standard deviation of the repeatability of the variation coefficient was 13,48%. Blood samples of the same horse resulted in ACTH levels of 121 pg/ml in the first probe and in < 5 pg/ml in the second probe. Standard deviation of measured ACTH values between the laboratories was +/- 26,4 pg/ml (Ø 27,44 pg/ml). The standard deviation of the reproducibility of the variation coefficient was 18,36%. In a 20 year old gelding the lowest ACTH value was 60.9 pg/ml whereas the highest measured value was 108 pg/ml. Immediate centrifugation of blood samples resulted in significantly higher ACTH values at an average of 11.6 pg/ml. The additional use of proteinase inhibitors (aprotinine) showed no influence on ACTH levels in this study.
Özdemir, Sadin; Okumuş, Veysi; Kılınç, Ersin; Bilgetekin, Havin; Dündar, Abdurrahman; Ziyadanogˇulları, Berrin
2012-09-15
This article reports a method that is used for the preconcentration and determination of Cd(2+) and Co(2+) in vegetables, using Pleurotus eryngii immobilized Amberlite XAD-16 as a solid-phase biosorbent. The concentrations of metals were determined by inductively coupled plasma-optical spectrometry (ICP-OES). Critical parameters, such as the pH of the solution, flow rate, the amount of biosorbent, type and volume of eluent, and the sample volume, that affect the solid-phase extraction (SPE) procedure were optimized. The optimum extraction conditions were determined as being a pH of 6.0 for Cd(2+) and of 5.0 for Co(2+); a sample flow rate of 2.0 mL min(-1); 200.0mg of biosorbent; and 5.0 mL of 1.0 mol L(-1) HCl as eluent. The capacities of the biosorbent for metal uptake were found to be 11.3 and 9.8 mg g(-1) for Cd(2+) and Co(2+) ions, respectively. Limit of quantitations (LOQs) were found to be 0.67 and 0.82 ng mL(-1), respectively, for Cd(2+) and Co(2+). The linear working curves were observed to be in the linear range from 1.0 to 50.0 ng mL(-1), and possessed high correlation coefficients. The use of the SPE method showed 50.7- and 35.7-fold improvements in the sensitivities of ICP-OES. The developed method was successfully applied to NCS ZC-73014 (a certified reference tea sample). Relative standard deviations (RSD) were lower than 5.0%. The Cd(2+) and Co(2+) concentrations in the different parts (leave, root, stem, and fruit) of purslane, onion, rocket, okra, and aubergine were determined after microwave digestion and solid-phase extraction by P. eryngii immobilized on Amberlite XAD-16. Copyright © 2012 Elsevier B.V. All rights reserved.
van Staden, J F; Mashamba, Mulalo G; Stefan, Raluca I
2002-09-01
An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid is proposed. A solution of 0.1 mol L(-1) sodium chloride is used as carrier. Titration is achieved by aspirating acetic acid samples between two strong base-zone volumes into a holding coil and by channelling the stack of well-defined zones with flow reversal through a reaction coil to a potentiometric sensor where the peak widths were measured. A linear relationship between peak width and logarithm of the acid concentration was obtained in the range 1-9 g/100 mL. Vinegar samples were analysed without any sample pre-treatment. The method has a relative standard deviation of 0.4% with a sample frequency of 28 samples per hour. The results revealed good agreement between the proposed sequential injection and an automated batch titration method.
Effect of sample volume on metastable zone width and induction time
NASA Astrophysics Data System (ADS)
Kubota, Noriaki
2012-04-01
The metastable zone width (MSZW) and the induction time, measured for a large sample (say>0.1 L) are reproducible and deterministic, while, for a small sample (say<1 mL), these values are irreproducible and stochastic. Such behaviors of MSZW and induction time were theoretically discussed both with stochastic and deterministic models. Equations for the distribution of stochastic MSZW and induction time were derived. The average values of stochastic MSZW and induction time both decreased with an increase in sample volume, while, the deterministic MSZW and induction time remained unchanged. Such different behaviors with variation in sample volume were explained in terms of detection sensitivity of crystallization events. The average values of MSZW and induction time in the stochastic model were compared with the deterministic MSZW and induction time, respectively. Literature data reported for paracetamol aqueous solution were explained theoretically with the presented models.
Ballesteros, M; Boldt, J; Zickmann, B; Knothe, C; Hempelmann, G
1995-01-01
To describe the changes in cardiac function after administration of three different solutions infused after anesthetic induction. Thirty-six patients scheduled for elective aortocoronary bypass surgery were randomly distributed into three groups. Over a period of 25 min after anesthetic induction, 12 received 10 ml/kg of Ringer solution (low dose crystalloid group), 12 received 20 ml/kg of Ringer solution (high dose crystalloid group), and 12 received 10 ml/kg of Ringer solution with 10 ml/kg of hydroxi-ethyl-almidon solution 450,000 D, 0.7 substitution grade (group C-HEA). Minute volume, systemic and pulmonary pressures, osmolality of blood and urine, and plasma and urine sodium concentrations were measured before and after infusion of the assigned liquid. In spite of the volume infused, low dose crystalloid group showed a high incidence of oliguria, increased urinary osmolality and decreased sodium in urine. Cardiac and systolic indices and left ventricular work load remained stable after infusion of the assigned liquid in low and high dose crystalloid groups, whereas they increased significantly ion group C-HEA (+23%, +16% and +20%). Administration of restricted doses of crystalloids after anesthetic induction favors the retention of water and sodium. Higher doses of crystalloids weaken this effect. However, neither of these two regimens leads to a more effective cardiac work load. A combination of crystalloids and colloids administered immediately after anesthetic induction temporarily improves cardiac performance during surgery.
DNase 1 Retains Endodeoxyribonuclease Activity Following Gold Nanocluster Synthesis
2014-07-04
mM) was added to 2 mL of protein solution under vigorous stirring at 37 °C (Table 1). After 5 min, 200 μL of NaOH (1 M) was added to raise the pH to...12 for the 1, 5, and 10 mM HAuCl4 samples whereas 400 μL of NaOH (1M) was required to obtain a pH of 12 for the 20 mM HAuCl4 sample due to the... magnesium sulfate pH 5.0), containing 2 μg of dsDNA. The reaction was incubated at room temperature for 20 min followed by the addition of 2 units of
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berndt, B; Wuerl, M; Dedes, G
Purpose: To improve agreement of predicted and measured positron emitter yields in patients, after proton irradiation for PET-based treatment verification, using a novel dual energy CT (DECT) tissue segmentation approach, overcoming known deficiencies from single energy CT (SECT). Methods: DECT head scans of 5 trauma patients were segmented and compared to existing decomposition methods with a first focus on the brain. For validation purposes, three brain equivalent solutions [water, white matter (WM) and grey matter (GM) – equivalent with respect to their reference carbon and oxygen contents and CT numbers at 90kVp and 150kVp] were prepared from water, ethanol, sucrosemore » and salt. The activities of all brain solutions, measured during a PET scan after uniform proton irradiation, were compared to Monte Carlo simulations. Simulation inputs were various solution compositions obtained from different segmentation approaches from DECT, SECT scans, and known reference composition. Virtual GM solution salt concentration corrections were applied based on DECT measurements of solutions with varying salt concentration. Results: The novel tissue segmentation showed qualitative improvements in %C for patient brain scans (ground truth unavailable). The activity simulations based on reference solution compositions agree with the measurement within 3–5% (4–8Bq/ml). These reference simulations showed an absolute activity difference between WM (20%C) and GM (10%C) to H2O (0%C) of 43 Bq/ml and 22 Bq/ml, respectively. Activity differences between reference simulations and segmented ones varied from −6 to 1 Bq/ml for DECT and −79 to 8 Bq/ml for SECT. Conclusion: Compared to the conventionally used SECT segmentation, the DECT based segmentation indicates a qualitative and quantitative improvement. In controlled solutions, a MC input based on DECT segmentation leads to better agreement with the reference. Future work will address the anticipated improvement of quantification accuracy in patients, comparing different tissue decomposition methods with an MR brain segmentation. Acknowledgement: DFG-MAP and HIT-Heidelberg Deutsche Forschungsgemeinschaft (MAP); Bundesministerium fur Bildung und Forschung (01IB13001)« less
Cagirdi, Duygu; Altundag, Hüseyin; Imamoglu, Mustafa; Tuzen, Mustafa
2014-01-01
A simple and selective separation and preconcentration method was developed for the determination of Cu(ll) ions. This method is based on adsorption of Cu(ll) ions from aqueous solution on a bis(3-aminopropyl)amine modified silica gel column and flame atomic absorption spectrometric determination after desorption. Various analytical parameters such as pH, type of eluent solution and its volume, flow rate of sample and eluent, and sample volume were optimized. Effects of some cation, anion, and transition metal ions on the recoveries of Cu(ll) ions were also investigated. Cu(ll) ions were quantitatively recovered at pH 6; 5.0 mL of 2 M HCI was used as the eluent. The preconcentration factor was found to be 150. The LOD was 0.12 microg/L for Cu(ll). The accuracy of the method was confirmed by analysis of Tea Leaves (INCT-TL-1) and Fish Protein (DORM-3) certified reference materials. The optimized method was applied to various water and food samples for the determination of Cu(ll).
Code of Federal Regulations, 2014 CFR
2014-04-01
...: Dissolve 0.1 gram of quassin in 100 ml of 95 percent alcohol, then dilute 4 ml of the solution to 1,000 ml with distilled water, mix well and taste. (c) Identification test. Dissolve about 0.5 gram of quassin... hydrochloric acid and 1 mg of phloroglucinol and mix well. A red color develops. (d) Optical assay. When 1 gram...
Code of Federal Regulations, 2012 CFR
2012-04-01
...: Dissolve 0.1 gram of quassin in 100 ml of 95 percent alcohol, then dilute 4 ml of the solution to 1,000 ml with distilled water, mix well and taste. (c) Identification test. Dissolve about 0.5 gram of quassin... hydrochloric acid and 1 mg of phloroglucinol and mix well. A red color develops. (d) Optical assay. When 1 gram...
Code of Federal Regulations, 2013 CFR
2013-04-01
... hydrochloric acid and 1 mg of phloroglucinol and mix well. A red color develops. (d) Optical assay. When 1 gram...: Dissolve 0.1 gram of quassin in 100 ml of 95 percent alcohol, then dilute 4 ml of the solution to 1,000 ml with distilled water, mix well and taste. (c) Identification test. Dissolve about 0.5 gram of quassin...
Code of Federal Regulations, 2010 CFR
2010-04-01
... hydrochloric acid and 1 mg of phloroglucinol and mix well. A red color develops. (d) Optical assay. When 1 gram...: Dissolve 0.1 gram of quassin in 100 ml of 95 percent alcohol, then dilute 4 ml of the solution to 1,000 ml with distilled water, mix well and taste. (c) Identification test. Dissolve about 0.5 gram of quassin...
Code of Federal Regulations, 2011 CFR
2011-04-01
... hydrochloric acid and 1 mg of phloroglucinol and mix well. A red color develops. (d) Optical assay. When 1 gram...: Dissolve 0.1 gram of quassin in 100 ml of 95 percent alcohol, then dilute 4 ml of the solution to 1,000 ml with distilled water, mix well and taste. (c) Identification test. Dissolve about 0.5 gram of quassin...
Code of Federal Regulations, 2013 CFR
2013-07-01
... buffer. 3.350-mL burette for 1.0 N sodium hydroxide. 3.4Magnetic stirrer and stir bars. 3.5250-mL beaker... N sodium hydroxide solution. 4.2Hydroxylamine hydrochloride solution, 100 grams per liter, pH... prestandardized pH meter, 1.0 N hydrochloric acid, 0.1 N hydrochloric acid, and 0.1 N sodium hydroxide. 5.5Add 50...
Code of Federal Regulations, 2012 CFR
2012-07-01
... buffer. 3.350-mL burette for 1.0 N sodium hydroxide. 3.4Magnetic stirrer and stir bars. 3.5250-mL beaker... N sodium hydroxide solution. 4.2Hydroxylamine hydrochloride solution, 100 grams per liter, pH... prestandardized pH meter, 1.0 N hydrochloric acid, 0.1 N hydrochloric acid, and 0.1 N sodium hydroxide. 5.5Add 50...
Code of Federal Regulations, 2014 CFR
2014-07-01
... buffer. 3.350-mL burette for 1.0 N sodium hydroxide. 3.4Magnetic stirrer and stir bars. 3.5250-mL beaker... N sodium hydroxide solution. 4.2Hydroxylamine hydrochloride solution, 100 grams per liter, pH... prestandardized pH meter, 1.0 N hydrochloric acid, 0.1 N hydrochloric acid, and 0.1 N sodium hydroxide. 5.5Add 50...
Sighinolfi, G P; Gorgoni, C
1981-03-01
A method based on hydride generation for the AAS determination of selenium at nanogram levels in geological materials is described. The sample is decomposed by aqua regia attack in a sealed Teflon bomb. After treatment with hydrochloric acid, selenium is converted into hydrogen selenide by reaction with sodium borohydride and determined by AAS. Matrix interference effects have been investigated, but though they are rarely significant, the standard-additions method is recommended. The absolute sensitivity of the method is about 2.0 ng of Se (in 10 ml of solution). Detection limits of about 5-10 ng in a 1.0-g sample have been achieved with the use of "Suprapure" reagents. The selenium content of some USGS, CRPG and ANRT reference samples is reported.
Natural diatomite process for removal of radioactivity from liquid waste.
Osmanlioglu, Ahmet Erdal
2007-01-01
Diatomite has a number of unique physical properties and has found diversified industrial utilization. The filtration characteristics are particularly significant in the purification of liquids. The purpose of this study was to test natural diatomaceous earth (diatomite) as an alternative material that could be used for removal of radioactivity from liquid waste. A pilot-scale column-type device was designed. Natural diatomite samples were ground, sieved and prepared to use as sorption media. In this study, real waste liquid was used as radioactive liquid having special conditions. The liquid waste contained three radionuclides (Cs-137, Cs-134 and Co-60). Following the treatment by diatomite, the radioactivity of liquid waste was reduced from the initial 2.60 Bq/ml to less than 0.40 Bq/ml. The results of this study show that most of the radioactivity was removed from the solution by processing with diatomite.
Determination of amantadine and rimantadine using a sensitive fluorescent probe
NASA Astrophysics Data System (ADS)
Wang, Guang-Quan; Qin, Yan-Fang; Du, Li-Ming; Li, Jun-Fei; Jing, Xu; Chang, Yin-Xia; Wu, Hao
2012-12-01
Amantadine hydrochloride (AMA) and rimantadine hydrochloride (RIM) are non-fluorescent in aqueous solutions. This property makes their determination through direct fluorescent method difficult. The competing reactions and the supramolecular interaction mechanisms between the two drugs and coptisine (COP) as they fight for occupancy of the cucurbit[7]uril (CB[7]) cavity, were studied using spectrofluorimetry, 1H NMR, and molecular modeling calculations. Based on the significant quenching of the supramolecular complex fluorescence intensity, a fluorescent probe method of high sensitivity and selectivity was developed to determine AMA or RIM in their pharmaceutical dosage forms and in urine samples with good precision and accuracy. The linear range of the method was from 0.0040 to 1.0 μg mL-1 with a detection limit ranging from 0.0012 to 0.0013 μg mL-1. This shows that the proposed method has promising potential for therapeutic monitoring and pharmacokinetics and for clinical application.
Simultaneous Thermal Analysis of Remediated Nitrate Salt Surrogates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wayne, David Matthew
The actinide engineering and science group (MET-1) have completed simultaneous thermal analysis and offgas analysis by mass spectrometry (STA-MS) of remediated nitrate salt (RNS) surrogates formulated by the high explosives science and technology group (M-7). The 1.0 to 1.5g surrogate samples were first analyzed as received, then a new set was analyzed with 100-200mL 10M HNO 3 +0.3 MHF added, and a third set was analyzed after 200 mL of a concentrated Pu-AM spike (in 10M HNO 3 +0.3 MHF) was added. The acid and spike solutions were formulated by the actinide analytical chemistry group (C-AAC) using reagent-grade HNO 3more » and HF, which was also used to dissolve a small quantity of mixed, high-fired PuO 2/ AmO 2 oxide.« less
Han, Meihua; Chen, Jing; Chen, Shilin; Wang, Xiangtao
2009-05-01
To establish a RP-HPLC method for content and entrapment efficiency of 20 (S)-protopanaxadiol in pharmacosomes. The separation was performed with a COSMOSIL 5 C18-MS-II column (4.6 mm x 250 mm, 5 mmicrom) using methanol-water (95:5) as the mobile phase and detected at 203 nm. The flow rate was 1.0 mL x min(-1) and 50 microL sample solution was injected for each time. The calibration curve was linear within the range 0.1-0.5 mg x mL(-1) (r = 0. 9999) , the intra-day RSD and inter-day RSD were less than 2% and the average recovery was between 101.44%-103.11% (n = 3). The method is simple, accurate, sensitive and applicable for determination of content and entrapment efficiency of 20 (S)-protopanaxadiol pharmacosomes.
Efficacy of small-volume simethicone given at least 30 min before gastroscopy.
Song, Mingjun; Kwek, Andrew Boon Eu; Law, Ngai Moh; Ong, Jeannie Peng Lan; Tan, Jessica Yi-Lyn; Harichander Thurairajah, Prem; Ang, Daphne Shih Wen; Ang, Tiing Leong
2016-11-06
To evaluate the efficacy of 5 mL simethicone solution in decreasing gastric foam if given at least 30 min before gastroscopy. This was a randomized, placebo controlled, endoscopist blinded study performed at Changi General Hospital. Patients were at least 21 years old, had no prior surgical resection of the upper gastrointestinal tract, and scheduled for elective diagnostic gastroscopies. The primary outcome was the total mucosal visibility score (TMVS) which was evaluated using McNally score. The sample size was calculated to be 24 per group (SD 2.4, 80% power, P < 0.05, 2-sample t test). Fifty-four patients were randomised to receive either simethicone [1 mL liquid simethicone (100 mg) in 5 mL of water] or placebo (5 mL of water) at least 30 min before their gastroscopy. Six accredited consultants conducted the gastroscopy, and the interobserver agreement of scoring TMVS was good with a Kappa statistic of 0.73. The simethicone group had significantly better mean TMVS compared to placebo (5.78 ± SD 1.65 vs 8.89 ± SD 1.97, P < 0.001). The improvement was statistically significant for the duodenum and the gastric antrum, angularis, body, and fundus. Percent 51.9 of patients in the simethicone group had a TMVS of 4 (no bubbles at all) to 5 (only 1 area with minimal bubbles), while in the placebo group 3.7% of patients had TMVS of 4 or 5. The number needed to treat was 2.1 to avoid a TMVS of 6 and more. The simethicone group also had a significantly shorter procedure time with less volume of additional flushes required during gastroscopy to clear away obscuring gastric foam. With a premedication time of at least 30 min, 5 mL simethicone can significantly decrease gastric foam, decrease the volume of additional flushes, and shorten gastroscopy time.
Efficacy of small-volume simethicone given at least 30 min before gastroscopy
Song, Mingjun; Kwek, Andrew Boon Eu; Law, Ngai Moh; Ong, Jeannie Peng Lan; Tan, Jessica Yi-Lyn; Harichander Thurairajah, Prem; Ang, Daphne Shih Wen; Ang, Tiing Leong
2016-01-01
AIM To evaluate the efficacy of 5 mL simethicone solution in decreasing gastric foam if given at least 30 min before gastroscopy. METHODS This was a randomized, placebo controlled, endoscopist blinded study performed at Changi General Hospital. Patients were at least 21 years old, had no prior surgical resection of the upper gastrointestinal tract, and scheduled for elective diagnostic gastroscopies. The primary outcome was the total mucosal visibility score (TMVS) which was evaluated using McNally score. The sample size was calculated to be 24 per group (SD 2.4, 80% power, P < 0.05, 2-sample t test). RESULTS Fifty-four patients were randomised to receive either simethicone [1 mL liquid simethicone (100 mg) in 5 mL of water] or placebo (5 mL of water) at least 30 min before their gastroscopy. Six accredited consultants conducted the gastroscopy, and the interobserver agreement of scoring TMVS was good with a Kappa statistic of 0.73. The simethicone group had significantly better mean TMVS compared to placebo (5.78 ± SD 1.65 vs 8.89 ± SD 1.97, P < 0.001). The improvement was statistically significant for the duodenum and the gastric antrum, angularis, body, and fundus. Percent 51.9 of patients in the simethicone group had a TMVS of 4 (no bubbles at all) to 5 (only 1 area with minimal bubbles), while in the placebo group 3.7% of patients had TMVS of 4 or 5. The number needed to treat was 2.1 to avoid a TMVS of 6 and more. The simethicone group also had a significantly shorter procedure time with less volume of additional flushes required during gastroscopy to clear away obscuring gastric foam. CONCLUSION With a premedication time of at least 30 min, 5 mL simethicone can significantly decrease gastric foam, decrease the volume of additional flushes, and shorten gastroscopy time. PMID:27867691
NASA Astrophysics Data System (ADS)
Attaf, A.; Benkhetta, Y.; Saidi, H.; Bouhdjar, A.; Bendjedidi, H.; Nouadji, M.; Lehraki, N.
2015-03-01
In this work, we used a system based on ultrasonic spray pyrolysis technique. By witch, we have deposited thin films of zinc oxide (ZnO) with the variation of solution flow rate from 50 ml / h to 150 ml / h, and set other parameters such as the concentration of the solution, the deposition time, substrate temperature and the nozzel -substrate distance. In order to study the influence of the solution flow rate on the properties of the films produced, we have several characterization techniques such as X-ray diffraction to determine the films structure, the scanning electron microscopy SEM for the morphology of the surfaces, EDS spectroscopy for the chemical composition, UV-Visible-Nir spectroscopy for determination the optical proprieties of thin films.The experimental results show that: the films have hexagonal structure at the type (wurtzite), the average size of grains varies from 20.11 to 32.45 nm, the transmittance of the films equals 80% in visible rang and the band gap is varied between 3.274 and 3.282 eV, when the solution flow rate increases from 50 to 150 ml/h.
Nayak, Ranganath N; Dixitraj, P T; Nayak, Aarati; Bhat, Kishore
2015-09-01
This study aimed at evaluating the anti-microbial activity of spore powder of Ganoderma lucidum on Prevotella intermedia isolated from subgingival plaque from chronic periodontitis patients. Written informed consent was obtained from each subject enrolled in the study. The Institutional Ethics Committee granted the ethical clearance for the study. This study included 20 patients diagnosed with chronic periodontitis. Pooled subgingival plaque samples were collected using sterile curettes from the deepest sites of periodontal pockets. The collected samples were then transported in 1 mL of reduced transport fluid. The organisms were cultured and confirmed. These organisms were then used for minimum inhibitory concentration (MIC) procedure. Mean of the MIC value obtained was calculated. Thirteen out of the 20 clinical samples were tested that showed sensitivity at various concentrations. Five samples showed sensitivity at all concentrations. Twelve samples showed sensitivity at 8 mcg/ml. Eleven samples showed sensitivity at 4 mcg/ml, 8 samples showed sensitivity at 2 mcg/ml, and 5 samples showed sensitivity even at 1 mcg/ml. Mean MIC value of G. lucidum spore powder for P. intermedia obtained was 3.62 mcg/ml. G. lucidum with its multipotential bioactivity could be used as an anti-microbial, in conjunction with conventional therapy in periodontal disease.
An Investigation of the Sample Performance of Two Nonnormality Corrections for RMSEA
ERIC Educational Resources Information Center
Brosseau-Liard, Patricia E.; Savalei, Victoria; Li, Libo
2012-01-01
The root mean square error of approximation (RMSEA) is a popular fit index in structural equation modeling (SEM). Typically, RMSEA is computed using the normal theory maximum likelihood (ML) fit function. Under nonnormality, the uncorrected sample estimate of the ML RMSEA tends to be inflated. Two robust corrections to the sample ML RMSEA have…
Arghavani-Beydokhti, Somayeh; Rajabi, Maryam; Asghari, Alireza
2017-07-01
A novel, efficient, rapid, simple, sensitive, selective, and environmentally friendly method termed magnetic dispersive micro solid-phase extraction combined with supramolecular solvent-based microextraction (Mdμ-SPE-SSME) followed by high-performance liquid chromatography (HPLC) with UV detection is introduced for the simultaneous microextraction of cholesterol-lowering drugs in complicated matrices. In the first microextraction procedure, using layered double hydroxide (LDH)-coated Fe 3 O 4 magnetic nanoparticles, an efficient sample cleanup is simply and rapidly provided without the need for time-consuming centrifugation and elution steps. In the first step, desorption of the target analytes is easily performed through dissolution of the LDH-coated magnetic nanoparticles containing the target analytes in an acidic solution. In the next step, an emulsification microextraction method based on a supramolecular solvent is used for excellent preconcentration, ultimately resulting in an appropriate determination of the target analytes in real samples. Under the optimal experimental conditions, the Mdμ-SPE-SSME-HPLC-UV detection procedure provides good linearity in the ranges of 1.0-1500 ng mL -1 , 1.5-2000 ng mL -1 , and 2.0-2000 ng mL -1 with coefficients of determination of 0.995 or less, low limits of detection (0.3, 0.5, and 0.5 ng mL -1 ), and good extraction repeatabilities (relative standard deviations below 7.8%, n = 5) in deionized water for rosuvastatin, atorvastatin, and gemfibrozil, respectively. Finally, the proposed method is successfully applied for the determination of the target analytes in complicated matrices. Graphical Abstract Mdμ-SPE-SSME procedure.
Stability of thiopental sodium and propofol in polypropylene syringes at 23 and 4 degrees C.
Chernin, E L; Stewart, J T; Smiler, B
1996-07-01
The stability of thiopental sodium and propofol in an admixture stored in polypropylene syringes at room temperature and under refrigeration was studied. Propofol injection 10 mg/ mL and thiopental sodium 25 mg/mL were mixed to final concentrations of 5 and 12.5 mg/mL, respectively. The admixture was put into 60-mL polypropylene syringes, and two syringes were stored at 23 degrees C and two at 4 degrees C. For solutions stored at 23 degrees C, samples were taken at 0, 4, 8, 24, 48, 72, 120, 168, 216, 240, and 264 hours, and for samples stored at 4 degrees C, samples were taken at 0, 4, 8, 24, 48, 72, 120, 168, 216, and 312 hours. Drug concentrations were determined by high-performance liquid chromatography. Thiopental sodium and propofol retained > 90% of their initial concentrations for up to 312 hours at 4 degrees C. At 23 degrees C, > 90% of the initial concentration was retained by propofol for up to 120 hours and by thiopental sodium for up to 240 hours. No visual changes or significant change in pH occurred in any sample. When mixed and stored in polypropylene syringes, propofol 5 mg/mL and thiopental sodium 12.5 mg/mL were stable for up to 312 hours at 4 degrees C and for up to 120 hours at 23 degrees C.
Lewis, Alastair C.; Shaw, Marvin D.
2016-01-01
Stir bar sorptive extraction is a powerful technique for the extraction and analysis of organic compounds in aqueous matrices. Carbonyl compounds are ubiquitous components in rainwater, however, it is a major challenge to accurately identify and sensitively quantify carbonyls from rainwater due to the complex matrix. A stir bar sorptive extraction technique was developed to efficiently extract carbonyls from aqueous samples following chemical derivatization by O‐(2,3,4,5,6‐pentafluorobenzyl) hydroxylamine hydrochloride. Several commercial stir bars in two sizes were used to simultaneously measure 29 carbonyls in aqueous samples with detection by gas chromatography with mass spectrometry. A 100 mL aqueous sample was extracted by stir bars and the analytes on stir bars were desorbed into a 2 mL solvent solution in an ultrasonic bath. The preconcentration Coefficient for different carbonyls varied between 30 and 45 times. The limits of detection of stir bar sorptive extraction with gas chromatography mass spectrometry for carbonyls (10–30 ng/L) were improved by ten times compared with other methods such as gas chromatography with electron capture detection and stir bar sorptive extraction with high‐performance liquid chromatography and mass spectrometry. The technique was used to determine carbonyls in rainwater samples collected in York, UK, and 20 carbonyl species were quantified including glyoxal, methylglyoxal, isobutenal, 2‐hydroxy ethanal. PMID:27928898
Detection of cocaine and benzoylecgonine in formalin fixed rat tissues.
Hilal, Ahmet; Dağlioğlu, Nebīle; Battal, Dīlek; Yener, Fadīle; Dağlioğlu, Kenan
2009-09-01
The stability of drugs in formalin solution is an important factor in forensic investigation. Tissues (liver, lung, kidney, brain) taken from rats, which have been poisoned acutely with cocaine, were preserved in two different conditions, analyzed by GC-MS, and then compared. Organs of the first group were preserved and stored at -20 degrees C without adding formalin, whereas the organs of the second group were preserved and stored in formalin solution at room temperature (25 degrees C). Serum samples were taken immediately after poisoning and studied as well. In specimens stored at -20 degrees C, cocaine and its metabolite benzoylecgonine were detected in the tissues. Only benzoylecgonine was detected both in tissues and their formalin solution. It was observed that the distribution of cocaine in tissues had differed depending on the preservation conditions. The formalin solution in which benzoylecgonine was mostly detected was from liver. As a result, cocaine was detected in tissues stored at -20 degrees C. It is recommended that both the formalin-fixed tissues and formalin solution should be analyzed concurrently to assure the accurate results (LOD = 3 ng/ml).
Solution of reduced graphene oxide synthesized from coconut shells and its optical properties
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mas’udah, Kusuma Wardhani, E-mail: masudahkusuma@ymail.com; Faculty of Mathematics and Natural Sciences, Univesitas Pesantren Tinggi Darul Ulum, PP. Darul ‘Ulum Tromol Pos 10 Peterongan Jombang 61481; Nugraha, I Made Ananta, E-mail: anantanugraha25@gmail.com
Reduced graphene oxide (r-GO)powder has been prepared from coconut shells by carbonization process at 400°C for 3, 4 and 5 hours.Theresulted sample mass was reduced to be 60% relativelycompared to the starting material. The longer heating duration has also led to the rGO with reduced crystalinity according to the X-ray diffractometry data and TEM. The rGO solution was prepared by adding powders of 5, 10 and 15 grams into 50 ml destiled water and then centrifused at 6000 rpm for 30 minutes.The resulted solutions were seen to be varied form clear transparant, light and dark yellow to black. Measurement using particle sizemore » analyser shows that the individual rGO particles tends to be agglomerating each others to form bigger size clustering, manifested by the observed bigger size particles for the increasing amount of soluted rGO powders in water.The varying UV-visible spectra of these rGO solutions together with their optical bandgaps will also be discussed in this study.« less
Shaw, Angela; Helterbran, Kara; Evans, Michael R; Currey, Christopher
2016-12-01
The desire for local, fresh produce year round is driving the growth of hydroponic growing systems in the United States. Many food crops, such as leafy greens and culinary herbs, grown within hydroponics systems have their root systems submerged in recirculating nutrient-dense fertilizer solutions from planting through harvest. If a foodborne pathogen were introduced into this water system, the risk of contamination to the entire crop would be high. Hence, this study was designed to determine whether Escherichia coli O157:H7, non-O157 Shiga toxin-producing E. coli , and Salmonella were able to survive and reproduce in two common hydroponic fertilizer solutions and in water or whether the bacteria would be killed or suppressed by the fertilizer solutions. All the pathogens grew by 1 to 6 log CFU/ml over a 24-h period, depending on the solution. E. coli O157:H7 reached higher levels in the fertilizer solution with plants (3.12 log CFU/ml), whereas non-O157 Shiga toxin-producing E. coli and Salmonella reached higher levels in the fertilizer solution without plants (1.36 to 3.77 log CFU/ml). The foodborne pathogens evaluated here survived for 24 h in the fertilizer solution, and populations grew more rapidly in these solutions than in plain water. Therefore, human pathogens entering the fertilizer solution tanks in hydroponic systems would be expected to rapidly propagate and spread throughout the system and potentially contaminate the entire crop.
Prüller, Florian; Wagner, Jasmin; Raggam, Reinhard B; Hoenigl, Martin; Kessler, Harald H; Truschnig-Wilders, Martie; Krause, Robert
2014-07-01
Testing for (1→3)-beta-D-glucan (BDG) is used for detection of invasive fungal infection. However, current assays lack automation and the ability to conduct rapid single-sample testing. The Fungitell assay was adopted for automation and evaluated using clinical samples from patients with culture-proven candidemia and from culture-negative controls in duplicate. A comparison with the standard assay protocol was made in order to establish analytical specifications. With the automated protocol, the analytical measuring range was 8-2500 pg/ml of BDG, and precision testing resulted in coefficients of variation that ranged from 3.0% to 5.5%. Samples from 15 patients with culture-proven candidemia and 94 culture-negative samples were evaluated. All culture-proven samples showed BDG values >80 pg/ml (mean 1247 pg/ml; range, 116-2990 pg/ml), which were considered positive. Of the 94 culture-negative samples, 92 had BDG values <60 pg/ml (mean, 28 pg/ml), which were considered to be negative, and 2 samples were false-positive (≥80 pg/ml; up to 124 pg/ml). Results could be obtained within 45 min and showed excellent agreement with results obtained with the standard assay protocol. The automated Fungitell assay proved to be reliable and rapid for diagnosis of candidemia. It was demonstrated to be feasible and cost efficient for both single-sample and large-scale testing of serum BDG. Its 1-h time-to-result will allow better support for clinicians in the management of antifungal therapy. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
González-Andrade, Martin; Benito-Peña, Elena; Mata, Rachel; Moreno-Bondi, Maria C
2012-04-01
This paper describes the development of a novel on-line biosensor based on a fluorescently labeled human calmodulin (CaM), hCaM M124C-mBBr, immobilized on controlled-pore glass (CPG), for the analysis of trifluoroperazine (TFP); a phenothiazine drug in human urine samples. The device was automated by packing hCaM M124C-mBBr-CPG in a continuous-flow microcell connected to a monitoring system, composed of a bifurcated optical fiber coupled to a spectrofluorometer. Operating parameters of the on-line biosensor (flow rate, sample injection volume, and carrier solution and buffer pH) were studied and optimized. Under the optimal conditions, the biosensor provides a detection and a quantification limit of 0.24 and 0.52 μg mL(-1), respectively, and a dynamic range from 0.52 to 61.05 μg mL(-1) TFP (n = 5, correlation coefficient 0.998). The response time (t(100)) was shorter than 42 s (recovery time <4.5 min) and reproducibility and repeatability of the TFP measurements, within the linear response range, were lower than 1.4 and 2.7%, respectively. The device was successfully applied to the analysis of TFP in spiked human urine samples with recoveries ranging between 97 and 101% and with RSDs lower than 5.9%.
Determination of iodine and molybdenum in milk by quadrupole ICP-MS.
Reid, Helen J; Bashammakh, Abdul A; Goodall, Phillip S; Landon, Mark R; O'Connor, Ciaran; Sharp, Barry L
2008-03-15
A reliable method for the determination of iodine and molybdenum in milk samples, using alkaline digestion with tetramethylammonium hydroxide and hydrogen peroxide, followed by quadrupole ICP-MS analysis, has been developed and tested using certified reference materials. The use of He+O2 (1.0 ml min(-1) and 0.6 ml min(-1)) in the collision-reaction cell of the mass spectrometer to remove (129)Xe+-- initially to enable the determination of low levels of 129I--also resulted in the quantitative conversion of Mo(+) to MoO2+ which enabled the molybdenum in the milk to be determined at similar mass to the iodine with the use of Sb as a common internal standard. In order to separate and pre-concentrate iodine at sub microg l(-1) concentrations, a novel method was developed using a cation-exchange column loaded with Pd2+ and Ca2+ ions to selectively retain iodide followed by elution with a small volume of ammonium thiosulfate. This method showed excellent results for aqueous iodide solutions, although the complex milk digest matrix made the method unsuitable for such samples. An investigation of the iodine species formed during oxidation and extraction of milk sample digests was carried out with a view to controlling the iodine chemistry.
Freitas, Fagner Luiz da Costa
2014-01-01
Metabolic and morphometric alterations of the duodenal villi caused by parasitism of chickens by Eimeria maxima were evaluated, using 100 male Cobb birds, randomly distributed into two groups (control and infected). The infected group was inoculated with 0.5 ml of a solution containing 5 × 10³ sporulated oocysts of Eimeria maxima. Ten birds per sample were sacrificed on the 6th, 11th, 22nd and 41st days post-infection (dpi). In order to evaluate the alterations, samples of duodenum, jejunum and ileum fragments were collected after necropsy for histological analysis. Villus biometry was determined by means of a slide graduated in microns that was attached to a binocular microscope. To evaluate the biochemical data, 5 ml of blood were sampled from the birds before sacrifice. The statistical analyses were performed using the GraphPad 5 statistical software for Windows. Tukey's multiple comparison test (p <0.05) was performed for the different dpi's and the unpaired t test for the difference between the groups. Infection by E. maxima causes both qualitative and quantitative alterations to the structure of the intestinal villi, thereby interfering with the absorption of nutrients such as calcium, phosphorus, magnesium, protein and lipids, with consequent reductions in the birds' weights.
Shah, Bhavna; Patil, Pravin; Shah, Hirva
2014-01-01
A simple, accurate and low cost spectrophotometric method is proposed for the determination of the synthesized paracetamol derivative; 4-acetamidophenyl N'-(sulphanilamide) acetate (APSA) in biological fluids. The spectrophotometric method is based on a condensation reaction between the alcoholic solution of APSA and acidic solution of p-dimethylaminobenzaldeyde (DPMK) to generate a yellow colored product. The linear range for the determination of APSA was 1-10 µg mL(-1) with molar absorptivity of 3.6877 × 10(4) L mol(-1) cm(-1) and Sandell's sensitivity of 0.001 µg cm-2/0.001 absorbance unit. During the inter-day and intra-day analysis, the relative standard deviation for replicated determination of APSA was found to be less than 2.0% and accuracy was 99.20-101.60% and 99.10-101.30% in blood and urine samples, respectively. There was no interference with commonly used blood and urine sample. The developed spectrophotometric method was successfully applied to assess APSA in biological fluids.
Specificity of coliphages in evaluating marker efficacy: a new insight for water quality indicators.
Mookerjee, Subham; Batabyal, Prasenjit; Halder, Madhumanti; Palit, Anup
2014-11-01
Conventional procedures for qualitative assessment of coliphage are time consuming multiple step approach for achieving results. A modified and rapid technique has been introduced for determination of coliphage contamination among potable water sources during water borne outbreaks. During December 2013, 40 water samples from different potable water sources, were received for water quality analyses, from a jaundice affected Municipality of West Bengal, India. Altogether, 30% water samples were contaminated with coliform (1-20 cfu/ml) and 5% with E. coli (2-5 cfu/ml). Among post-outbreak samples, preponderance of coliform has decreased (1-4 cfu/ml) with total absence of E. coli. While standard technique has detected 55% outbreak samples with coliphage contamination, modified technique revealed that 80%, double than that of bacteriological identification rate, were contaminated with coliphages (4-20 pfu/10 ml). However, post-outbreak samples were detected with 1-5 pfu/10 ml coliphages among 20% samples. Coliphage detection rate through modified technique was nearly double (50%) than that of standard technique (27.5%). In few samples (with coliform load of 10-100 cfu/ml), while modified technique could detect coliphages among six samples (10-20 pfu/10 ml), standard protocol failed to detect coliphage in any of them. An easy, rapid and accurate modified technique has thereby been implemented for coliphage assessment from water samples. Coliform free water does not always signify pathogen free potable water and it is demonstrated that coliphage is a more reliable 'biomarker' to ascertain contamination level in potable water. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Blanford, W. J.; Neil, L.
2017-12-01
To better evaluate the potential for toxic organic chemicals to migrate upward through the rock strata from hydraulic fracturing zones and into groundwater resources, a series of miscible displacement solute transport studies of cores of Berea Sandstone have been conducted using hydrostatic core holder. These tests involved passing aqueous solutions with natural background level of salts using a high pressure LC pump through 2 in wide by 3 in long unfractured cores held within the holder. Relative solute transport of 100 to 500ml pulses of target solutes including a series of chlorinated solvents and methylated benzenes was measured through in-line UV and fluorescence detectors and manual sampling and analysis with GCMS. The results found these sandstones to result in smooth ideal shaped breakthrough curves. Analysis with 1D transport models (CXTFIT) of the results found strong correlation with chemical parameters (diffusion coefficients, aqueous solubility, and octanol-water partitioning coefficients) showing that these parameter and QSPR relationships can be used to make accurate predictions for such a system. In addition to the results of the studies, lessons learned from this novel use of a coreholder for evaluation of porosity, water-saturated permeability, and solute transport of these sandstones (K = 1.5cm/day) and far less permeable sandstones samples (K = 0.15 cm/yr) from a hydraulic fracturing site in central Pennsylvania will be presented.
Leggio, G M; Incognito, T; Privitera, G; Marano, M R; Drago, F
2006-12-01
To evaluate the relative bioavailability of T4 sodium and liothyronine sodium (T3), administered in single doses as oral solution (drops) and tablet forms, according to two separate study protocols. Twenty-four healthy, male volunteers were included in both studies. Two test drugs containing T4 or T3 (T4-Ibsa and T3-Ibsa, respectively) were compared to two reference drugs, ie Eutirox 100 and Ti-tre tablets, respectively. A single oral dose of 100 microg (1 ml or 1 tablet) of T4 and 20 microg (1 ml or 1 tablet) of T3 were administered with an open, randomized, crossover design. T4 and T3 serum concentrations were determined by a validated immunoassay in electro-chemo-luminescence method. Study 1: after administration of T4-Ibsa oral solution, Cmax was 14.26+/-0.61 microg/dl, AUC0-t was 282.70 +/-14.29 microg/dl/h, Tmax was 2.71+/-0.25 h. After administration of Eutirox 100 tablets, Cmax was 14.34+/-0.59 microg/dl, AUC0-t was 279.42+/-9.59 microg/dl/h and Tmax was 2.65+/-0.23 h. The 90% confidence interval ratios between test/reference drugs were 1.01 for AUC0-t and 0.99 for Cmax. Study 2: after administration of T3-Ibsa oral solution, Cmax was 3.19+/-0.25 ng/ml, AUC0-t was 44.79+/-2.15 ng/ml/h and Tmax was 2.31+/-0.25 h. After administration of Ti-tre tablets, Cmax was 3.16+/-0.23 ng/ml, AUC0-t was 45.19+/-2.19 ng/ml/h and Tmax was 2.44+/-0.34 h. The 90% confidence interval ratios between test /reference drugs were 0.99 for AUC0-t and 1.01 for Cmax. The bioavailability of the two oral solutions (T4-Ibsa and T3-Ibsa oral solutions) and the corresponding tablet forms (Eutirox 100 and Ti-tre tablets) were confirmed and they can be considered bioequivalent and therapeutically interchangeable.
Allsop, T F; Pauli, J V
1975-12-01
A technique for ventriculolumbar perfusion of the cerebrospinal fluid space has been used to study the neuromuscular effects of low concentrations of magnesium and calcium in the cerebrospinal fluid of conscious sheep. Perfusion with synthetic cerebrospinal fluid solutions containing less than 0-6 mg magnesium/100 ml produced episodes of tetany which were abolished by perfusion with a solution of normal magnesium concentration. This suggests that the low cerebrospinal fluid magnesium concentrations reported in cases of hypomagneseamic tetany may result in changes within the central nervous system that could produce the nervous signs. Perfusates with a calcium concentration below 2-0 mg/100 ml caused hyperpnoea and continuous muscle tremors. Magnesium (0-6 mg/100 ml) and calcium (2-0 mg/100 ml) perfused simultaneously acted synergistically to produce signs characteristic of low levels of each of the ions.
Nano porous silicon microcavity sensor for determination organic solvents and pesticide in water
NASA Astrophysics Data System (ADS)
Pham, Van Hoi; Van Nguyen, Thuy; Nguyen, The Anh; Pham, Van Dai; Bui, Huy
2014-12-01
In this paper we present a sensing method using nano-porous silicon microcavity sensor, which was developed in order to obtain simultaneous determination of two volatile substances with different solvent concentrations as well as very low pesticide concentration in water. The temperature of the solution and the velocity of the air stream flowing through the solution have been used to control the response of the sensor for different solvent solutions. We study the dependence of the cavity-resonant wavelength shift on solvent concentration, velocity of the airflow and solution temperature. The wavelength shift depends linearly on concentration and increases with solution temperature and velocity of the airflow. The dependence of the wavelength shift on the solution temperature in the measurement contains properties of the temperature dependence of the solvent vapor pressure, which characterizes each solvent. As a result, the dependence of the wavelength shift on the solution temperature discriminates between solutions of ethanol and acetone with different concentrations. This suggests a possibility for the simultaneous determination of the volatile substances and their concentrations. On the other hand, this method is able to detect the presence of atrazine pesticide by the shift of the resonant wavelength, with good sensitivity (0.3 nm pg-1 ml) and limit of detection (LOD) (0.8-1.4 pg ml-1), that we tested for concentrations in the range from 2.15 to 21.5 pg ml-1, which is the range useful for monitoring acceptable water for human consumption.
Evaluating gold standard corpora against gene/protein tagging solutions and lexical resources
2013-01-01
Motivation The identification of protein and gene names (PGNs) from the scientific literature requires semantic resources: Terminological and lexical resources deliver the term candidates into PGN tagging solutions and the gold standard corpora (GSC) train them to identify term parameters and contextual features. Ideally all three resources, i.e. corpora, lexica and taggers, cover the same domain knowledge, and thus support identification of the same types of PGNs and cover all of them. Unfortunately, none of the three serves as a predominant standard and for this reason it is worth exploring, how these three resources comply with each other. We systematically compare different PGN taggers against publicly available corpora and analyze the impact of the included lexical resource in their performance. In particular, we determine the performance gains through false positive filtering, which contributes to the disambiguation of identified PGNs. Results In general, machine learning approaches (ML-Tag) for PGN tagging show higher F1-measure performance against the BioCreative-II and Jnlpba GSCs (exact matching), whereas the lexicon based approaches (LexTag) in combination with disambiguation methods show better results on FsuPrge and PennBio. The ML-Tag solutions balance precision and recall, whereas the LexTag solutions have different precision and recall profiles at the same F1-measure across all corpora. Higher recall is achieved with larger lexical resources, which also introduce more noise (false positive results). The ML-Tag solutions certainly perform best, if the test corpus is from the same GSC as the training corpus. As expected, the false negative errors characterize the test corpora and – on the other hand – the profiles of the false positive mistakes characterize the tagging solutions. Lex-Tag solutions that are based on a large terminological resource in combination with false positive filtering produce better results, which, in addition, provide concept identifiers from a knowledge source in contrast to ML-Tag solutions. Conclusion The standard ML-Tag solutions achieve high performance, but not across all corpora, and thus should be trained using several different corpora to reduce possible biases. The LexTag solutions have different profiles for their precision and recall performance, but with similar F1-measure. This result is surprising and suggests that they cover a portion of the most common naming standards, but cope differently with the term variability across the corpora. The false positive filtering applied to LexTag solutions does improve the results by increasing their precision without compromising significantly their recall. The harmonisation of the annotation schemes in combination with standardized lexical resources in the tagging solutions will enable their comparability and will pave the way for a shared standard. PMID:24112383
Development of a syringe pump assisted dynamic headspace sampling technique for needle trap device.
Eom, In-Yong; Niri, Vadoud H; Pawliszyn, Janusz
2008-07-04
This paper describes a new approach that combines needle trap devices (NTDs) with a dynamic headspace sampling technique (purge and trap) using a bidirectional syringe pump. The needle trap device is a 22-G stainless steel needle 3.5-in. long packed with divinylbenzene sorbent particles. The same sized needle, without packing, was used for purging purposes. We chose an aqueous mixture of benzene, toluene, ethylbenzene, and p-xylene (BTEX) and developed a sequential purge and trap (SPNT) method, in which sampling (trapping) and purging cycles were performed sequentially by the use of syringe pump with different distribution channels. In this technique, a certain volume (1 mL) of headspace was sequentially sampled using the needle trap; afterwards, the same volume of air was purged into the solution at a high flow rate. The proposed technique showed an effective extraction compared to the continuous purge and trap technique, with a minimal dilution effect. Method evaluation was also performed by obtaining the calibration graphs for aqueous BTEX solutions in the concentration range of 1-250 ng/mL. The developed technique was compared to the headspace solid-phase microextraction method for the analysis of aqueous BTEX samples. Detection limits as low as 1 ng/mL were obtained for BTEX by NTD-SPNT.
Anodic Oxidation of Furans in Aprotic Solvents.
1984-01-06
dissolved in 70 mL acetonitrile (0.003% water , K.F. titration) containing 0.1 M tetra-n-butyl ammonium tetrafluoroborate (TBAF). The solution was...solvent evaporated on a rotary evaporator at 25°C ( water bath temperature). The residue was extracted with 3 x 20 mL portions of diethylether, and the...results for a clean electrode in the same solution after presaturation with oxygen. To make the film conductive for the electrolyses , the voltage was
Minor, T; Hachenberg, A; Tolba, R; Pauleit, D; Akbar, S
2001-06-27
Our objective was to evaluate graft equilibration with high viscosity (University of Wisconsin solution [UW]) or low viscosity (Bretschneider's histidine-tryptophan-ketoglutarate [HTK]) during liver procurement from non-heart beating donors (NHBD) and the potential impact of a preceding fibrinolysis with streptokinase on postpreservation viability. After 60 min of cardiac arrest, rat livers were perfused by gravity (60 cm H2O) via the portal vein with either 60 ml of HTK, 20 ml of UW, or 20 ml of Ringer's solution (22 degrees C including 7500U of streptokinase) and, subsequently, 20 ml of UW. After 24 h of storage at 4 degrees C, viability of the livers was assessed upon isolated reperfusion in vitro. Magnetic resonance imaging revealed severe perfusion deficits, which were mildly attenuated with HTK, upon flush-out with UW. After preflush with streptokinase, a mostly homogenous distribution of the preservation solution was observed throughout the liver tissue. The choice of the flush-out solution (UW or HTK) had no influence on parenchymal enzyme leakage, hepatic bile production, or tissue levels of ATP after reperfusion of the livers. Fibrinolytic preflush, however, resulted in a relevant and significant improvement of structural integrity as well as functional and metabolic recovery. Compromised vascular tissue perfusion upon organ harvest in NHBD triggers graft dysfunction after cold storage and can easily be circumvented by temporary fibrinolysis before graft retrieval.
Computed tomography analysis of third webspace injections for interdigital neuroma.
Hembree, W Chad; Groth, Adam T; Schon, Lew C; Guyton, Gregory P
2013-04-01
Injection for interdigital neuroma (IDN) may not selectively target the common digital nerve. We investigated the anatomical localization and extent of extravasation with injection for IDN. Two fellowship-trained foot and ankle surgeons injected radiopaque contrast into the third webspace of 49 cadaveric specimens (29 with 2 mL and 20 with 1 mL). Computed tomography scan of each specimen was obtained. An independent blinded foot and ankle surgeon analyzed the scans. All injections were accurate. Contrast was found in the second (greater than 70%) and fourth (greater than 30%) webspaces in both injection volume groups. No contrast was found within the third metatarsophalangeal joint. Extravasation extent was significantly greater with 2 mL versus 1 mL of solution in the medial to lateral (27.9 [7.8] mm vs 23.7 [6.0] mm; P = .05) and distal to proximal (52.1 [13.7] mm vs 40.4 [16.1] mm; P = .01) planes. No differences were observed in extravasation extent between surgeons. Injection for IDN was accurate, and extravasation extended into adjacent webspaces in a large percentage of specimens with both solution volumes. Lower extent of extravasation with 1 mL of solution did not indicate better selectivity of injection. Steroid injections for interdigital neuroma were accurate for therapeutic purposes but not diagnostic, except potentially for distinguishing webspace pain from joint pain.
Miralles, Pablo; Chisvert, Alberto; Salvador, Amparo
2015-01-01
An analytical method for the simultaneous determination of hydroxytyrosol and tyrosol in different types of olive extract raw materials and cosmetic cream samples has been developed. The determination was performed by liquid chromatography with UV spectrophotometric detection. Different chromatographic parameters, such as mobile phase pH and composition, oven temperature and different sample preparation variables were studied. The best chromatographic separation was obtained under the following conditions: C18 column set at 35°C and isocratic elution of a mixture ethanol: 1% acetic acid solution at pH 5 (5:95, v/v) as mobile phase pumped at 1 mL min(-1). The detection wavelength was set at 280 nm and the total run time required for the chromatographic analysis was 10 min, except for cosmetic cream samples where 20 min runtime was required (including a cleaning step). The method was satisfactorily applied to 23 samples including solid, water-soluble and fat-soluble olive extracts and cosmetic cream samples containing hydroxytyrosol and tyrosol. Good recoveries (95-107%) and repeatability (1.1-3.6%) were obtained, besides of limits of detection values below the μg mL(-1) level. These good analytical features, as well as its environmentally-friendly characteristics, make the presented method suitable to carry out both the control of the whole manufacture process of raw materials containing the target analytes and the quality control of the finished cosmetic products. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Shiller, Alan M.
2003-01-01
It is well-established that sampling and sample processing can easily introduce contamination into dissolved trace element samples if precautions are not taken. However, work in remote locations sometimes precludes bringing bulky clean lab equipment into the field and likewise may make timely transport of samples to the lab for processing impossible. Straightforward syringe filtration methods are described here for collecting small quantities (15 mL) of 0.45- and 0.02-microm filtered river water in an uncontaminated manner. These filtration methods take advantage of recent advances in analytical capabilities that require only small amounts of waterfor analysis of a suite of dissolved trace elements. Filter clogging and solute rejection artifacts appear to be minimal, although some adsorption of metals and organics does affect the first approximately 10 mL of water passing through the filters. Overall the methods are clean, easy to use, and provide reproducible representations of the dissolved and colloidal fractions of trace elements in river waters. Furthermore, sample processing materials can be prepared well in advance in a clean lab and transported cleanly and compactly to the field. Application of these methods is illustrated with data from remote locations in the Rocky Mountains and along the Yukon River. Evidence from field flow fractionation suggests that the 0.02-microm filters may provide a practical cutoff to distinguish metals associated with small inorganic and organic complexes from those associated with silicate and oxide colloids.
Jeong, In-Seek; Kwak, Byung-Man; Ahn, Jang-Hyuk; Leem, Donggil; Yoon, Taehyung; Yoon, Changyong; Jeong, Jayoung; Park, Jung-Min; Kim, Jin-Man
2012-10-01
In this study, nonheated saponification was employed as a novel, rapid, and easy sample preparation method for the determination of cholesterol in emulsified foods. Cholesterol content was analyzed using gas chromatography with a flame ionization detector (GC-FID). The cholesterol extraction method was optimized for maximum recovery from baby food and infant formula. Under these conditions, the optimum extraction solvent was 10 mL ethyl ether per 1 to 2 g sample, and the saponification solution was 0.2 mL KOH in methanol. The cholesterol content in the products was determined to be within the certified range of certified reference materials (CRMs), NIST SRM 1544 and SRM 1849. The results of the recovery test performed using spiked materials were in the range of 98.24% to 99.45% with an relative standard devitation (RSD) between 0.83% and 1.61%. This method could be used to reduce sample pretreatment time and is expected to provide an accurate determination of cholesterol in emulsified food matrices such as infant formula and baby food. A novel, rapid, and easy sample preparation method using nonheated saponification was developed for cholesterol detection in emulsified foods. Recovery tests of CRMs were satisfactory, and the recoveries of spiked materials were accurate and precise. This method was effective and decreased the time required for analysis by 5-fold compared to the official method. © 2012 Institute of Food Technologists®
Wang, Shuo; Zhang, Xiangming; Zhang, Jing; Shao, Bing; Li, Shuming
2015-07-01
A method for the determination of 54 drugs in drinking water samples was developed by using ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometry (UPLC-ESI MS/MS). The target drugs in drinking water samples were enriched and cleaned-up by HLB solid-phase extraction (SPE) cartridges and then eluted with 5 mL methanol. The elute was collected, concentrated under a gentle stream of nitrogen gas, diluted with 0.4 mL 0.1% formic acid solution, and analyzed by UPLC-ESI MS/MS. The separation of the 54 drugs was performed on an ACQUITY UPLC™ BEH C18 column using mobile phases of 0.1% formic acid and methanol by gradient elution. The multiple reaction monitoring (MRM) mode was employed in mass spectrometry acquisition. The matrix-matched external standard calibration was used for quantitation. The results showed that the average recoveries of the drugs in ground water, tap water and surface water were 58.7%-104.4%, 53.1%-109.5%, and 50.7%-118.8%, respectively, and the corresponding relative standard deviations (RSD, n=6) were 0.3%-12.8%, 1.0%-15.5%, and 0.4%-19.3%, respectively. The method quantification limits (MQL) for target compounds were in the range of 0.002-5.000 ng/L. The developed method was applied to analyze the water samples from Beijing. The results showed that 26 drugs were detected in ground water samples.
Perilymph pharmacokinetics of locally-applied gentamicin in the guinea pig.
Salt, A N; Hartsock, J J; Gill, R M; King, E; Kraus, F B; Plontke, S K
2016-12-01
Intratympanic gentamicin therapy is widely used clinically to suppress the vestibular symptoms of Meniere's disease. Dosing in humans was empirically established and we still know remarkably little about where gentamicin enters the inner ear, where it reaches in the inner ear and what time course it follows after local applications. In this study, gentamicin was applied to the round window niche as a 20 μL bolus of 40 mg/ml solution. Ten 2 μL samples of perilymph were collected sequentially from the lateral semi-circular canal (LSCC) at times from 1 to 4 h after application. Gentamicin concentration was typically highest in samples originating from the vestibule and was lower in samples originating from scala tympani. To interpret these results, perilymph elimination kinetics for gentamicin was quantified by loading the entire perilymph space by injection at the LSCC with a 500 μg/ml gentamicin solution followed by sequential perilymph sampling from the LSCC after different delay times. This allowed concentration decline in perilymph to be followed with time. Gentamicin was retained well in scala vestibuli and the vestibule but declined rapidly at the base of scala tympani, dominated by interactions of perilymph with CSF, as reported for other substances. Quantitative analysis, taking into account perilymph kinetics for gentamicin, showed that more gentamicin entered at the round window membrane (57%) than at the stapes (35%) but the lower concentrations found in scala tympani were due to greater losses there. The gentamicin levels found in perilymph of the vestibule, which are higher than would be expected from round window entry alone, undoubtedly contribute to the vestibulotoxic effects of the drug. Furthermore, calculations of gentamicin distribution following targeted applications to the RW or stapes are more consistent with cochleotoxicity depending on the gentamicin concentration in scala vestibuli rather than that in scala tympani. Copyright © 2016 Elsevier B.V. All rights reserved.
Shahba, Ahmad Abdul-Wahhab; Ahmed, Abid Riaz; Alanazi, Fars Kaed; Mohsin, Kazi; Abdel-Rahman, Sayed Ibrahim
2018-04-25
Beside their solubility limitations, some poorly water-soluble drugs undergo extensive degradation in aqueous and/or lipid-based formulations. Multi-layer self-nanoemulsifying pellets (ML-SNEP) introduce an innovative delivery system based on isolating the drug from the self-nanoemulsifying layer to enhance drug aqueous solubility and minimize degradation. In the current study, various batches of cinnarizine (CN) ML-SNEP were prepared using fluid bed coating and involved a drug-free self-nanoemulsifying layer, protective layer, drug layer, moisture-sealing layer, and/or an anti-adherent layer. Each layer was optimized based on coating outcomes such as coating recovery and mono-pellets%. The optimized ML-SNEP were characterized using scanning electron microscopy (SEM), differential scanning calorimetry (DSC), X-ray diffraction (XRD), in vitro dissolution, and stability studies. The optimized ML-SNEP were free-flowing, well separated with high coating recovery. SEM showed multiple well-defined coating layers. The acidic polyvinylpyrrolidone:CN (4:1) solution presented excellent drug-layering outcomes. DSC and XRD confirmed CN transformation into amorphous state within the drug layer. The isolation between CN and self-nanoemulsifying layer did not adversely affect drug dissolution. CN was able to spontaneously migrate into the micelles arising from the drug-free self-nanoemulsifying layer. ML-SNEP showed superior dissolution compared to Stugeron® tablets at pH 1.2 and 6.8. Particularly, on shifting to pH 6.8, ML-SNEP maintained > 84% CN in solution while Stugeron® tablets showed significant CN precipitation leaving only 7% CN in solution. Furthermore, ML-SNEP (comprising Kollicoat® Smartseal 30D) showed robust stability and maintained > 97% intact CN within the accelerated storage conditions. Accordingly, ML-SNEP offer a novel delivery system that combines both enhanced solubilization and stabilization of unstable poorly soluble drugs.
[Analysis of perfluoroalkyl substances precursors in human milk from 12 provinces of China].
Yang, Lin; Yu, Xinping; Wang, Meng; Li, Jingguang; Wang, Yuxin; Zhao, Yunfeng; Wu, Yongning
2015-06-01
To explore the level of perfluoroalkyl substances (PFASs) precursors in Chinese human milk samples. The human milk samples were collected during the performance of Stockholm convention on survey of human milk in China in 2007. Based on the geographical location and dietary habits, China was divided into the south area and north area which 6 provinces were chosen from each area and there were 12 provinces in all. In each province, one urban site and two rural sites were selected to collect 80-110 samples. Mothers were randomly selected in each site to collect their breast milk. There were 1 237 individual human milk samples in all. For each province, the individual samples from the urban areas and the rural areas were pooled separately resulting in 24 pooled human milk samples. 11 PFAS precursors were measured in pooled samples by ultra-high performance liquid chromatography-tandem quadruple mass spectrometry (UPLC-MS/MS). The dietary exposure assessment of newborns was made. Three PFAS precursors were found above the detection limits, namely, 6:2 FTS, FHUEA, and 6:2 diPAP. Their concentration ranges were < Limit of determination (LOD) -47.46 pg/ml, < LOD -70.68 pg/ml and < LOD -35.08 pg/ml, respectively. The highest total PFAS precursor concentration 77.70 pg/ml was found in urban area samples from Shannxi Province. Rural area samples from Hubei had the lowest total PFAS precursor concentration, which was below the LOD. There were significant differences between rural and urban areas in many provinces, such as Shannxi (rural: 1.51 pg/ml; urban: 77.70 pg/ml), Shanghai (rural: 1.13 pg/ml; urban: 71.88 pg/ml), Jiangxi (rural: 65.39 pg/ml; urban: 0.55 pg/ml) and so on. The ranges estimated daily intake of 6:2 FTS, FHUEA and 6:2 diPAP of the samples from 12 provinces were 0.05-4.51, 1.13-6.72 and 1.15-3.34 ng · kg⁻¹ · d⁻¹. The results suggested the human exposure of PFAS precursors in China and the potential health impact of postnatal exposure through breastfeeding to infants. The level of PFAS precursors showed differences in regions, rural and urban places.
Shi, Zhihong; Li, Zhimin; Zhang, Shulan; Fu, Hongna; Zhang, Hongyi
2015-09-01
Based on the phase separation phenomenon of acetonitrile-water system at subzero temperature, a subzero-temperature liquid-liquid extraction coupled with ultra-performance liquid chromatography tandem quadrupole mass spectrometry : UPLC-MS-MS) method was developed for the simultaneous determination of 12 bioactive components in Gegen-Qinlian decoction. After optimization, the extraction conditions were set as follows: 3.0 mL of aqueous sample solution (pH 5.86) was extracted with 2 mL of acetonitrile at -35°C for 35 min. The separated acetonitrile phase was diluted 10-fold with water before UPLC-MS-MS analysis. Separation was performed on a Waters ACQUITY UPLC(®)BEH C18 column (2.1 × 100 mm i.d., 1.7 µm) with ammonium formate buffer solution (20 mmol L(-1), pH 3.2, adjusted by formic acid) and acetonitrile as mobile phase with gradient elution. Twelve target components could be separated within 10 min and quantified in multiple reaction monitoring mode, both positive and negative ionization modes were employed. Limits of detection were in the range of 0.0003-0.0451 μg mL(-1). Relative standard deviation values for intra- and interday precision were <2.71 and 8.94%, respectively. The established method provides a simple and effective framework for the quality control of Gegen-Qinlian decoction and related traditional Chinese medicinal preparations. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
[Guidelines for multivitamin administration in fortified human milk prepared for preterm infants].
Rigourd, V; Dridi Brahim, I; Smii, S; Razafimahefa, H; Quetin, F; Leroy, E; Pichon, C; Giuseppi, A; Berthier, L; Pommeret, B; Serreau, R
2017-02-01
To reach nutritional standards, human milk has to have 2g/dL of protein. In 2013, Lafeber stated that when human milk is fortified up to 2g/dL, it may increase its osmolality up to 500 mOsm/kg. He also warned that care must be taken when adding a drug or vitamins to human milk. We studied, for the first time, the impact of adding multivitamins (ADEC) on human fortified milk osmolality. The osmolality of 36 pasteurized, fortified human milk samples was measured. The amount of milk required as a solvent to maintain osmolality below 500 mOsm/kg was then determined. The osmolality of 2mL of fortified human milk reached up to 750 mOsm/kg when the multivitamins ADEC was added. The osmolality decreased proportionately as the solution was diluted and if vitamins are added in two half-doses each time. It is only with 20mL of milk that the osmolality lowers to its initial rate of 430 mOsm/kg. The stronger the milk's fortification is, the greater impact it has on the milk's osmolality. New nutritional recommendations for premature infants are needed. In the meantime, when the fortified milk intake is under 20mL, it is preferable to extend parenteral intakes with fat-soluble vitamins or reduce doses of vitamins in milk. Also, we should use enriched human milk as a fortifier and be cautious with indiscriminate fortification or when adding drugs and electrolyte solutions. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Incompatibility of Contrast Medium and Trisodium Citrate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Delcour, Christian, E-mail: christian.delcour@chu-charleroi.be; Bruninx, Guy
2013-02-15
To test the compatibility of trisodium citrate, a catheter lock solution, with iodinated contrast medium. Iohexol, iobitridol, iodixanol, ioxaglate, ioxithalamate, iomeprol, and iopromide were tested. In all tests, 2 ml of contrast medium were mixed with 2 ml of trisodium citrate solution. Iodixanol and ioxaglate provoked a highly viscous gluelike precipitation when mixed with trisodium citrate. A brief transient precipitate was observed with iohexol, iomeprol, and ioxithalamate. Permanent precipitation occurred with iobitridol and iopromide. One must be aware of the potential for precipitation when contrast medium is mixed with trisodium citrate solution. Before trisodium citrate solution is injected, the cathetermore » should be thoroughly flushed with saline if a contrast medium has previously been injected through it.« less
Cai, Yi; Li, Shao-Hua; Dou, Shuai; Yu, Yong-Liang; Wang, Jian-Hua
2015-01-20
The scope of dielectric barrier discharge (DBD) microplasma as a radiation source for optical emission spectrometry (OES) is extended by nickel carbonyl vapor generation. We proved that metal carbonyl completely avoids the extinguishing of plasma, and it is much more suitable for matching the DBD excitation and OES detection with respect to significant DBD quenching by concomitant hydrogen when hydride generation is used. A concentric quartz UV reactor allows sample solution to flow through the central channel wherein to efficiently receive the uniformly distributed UV irradiation in the confined cylindrical space between the concentric tubes, which facilitates effective carbonyl generation in a nickel solution. The carbonyl is transferred into the DBD excitation chamber by an argon stream for nickel excitation, and the characteristic emission of nickel at 232.0 nm is detected by a charge-coupled device (CCD) spectrometer. A 1.0 mL sample solution results in a linear range of 5-100 μg L(-1) along with a detection limit of 1.3 μg L(-1) and a precision of 2.4% RSD at 50 μg L(-1). The present DBD-OES system is validated by nickel in certified reference materials.
Solfrizzo, M; Visconti, A; Avantaggiato, G; Torres, A; Chulze, S
2001-01-01
Several adsorbent materials were tested at I mg/ml for their in vitro capacity to adsorb fumonisin B1(FB1) from aqueous solutions. Cholestyramine showed the best adsorption capacity (85% from a solution containing 200 microg/ml FB1) followed by activated carbon (62% FB1). Bentonite adsorbed only 12% of the toxin from a solution containing 13 microg/ml FB1, while celite was not effective even at the lowest tested FB1 concentration (3.2 microg/ml). Cholestyramine was tested in vivo to evaluate its capacity to reduce the bioavailability of fumonisins (FBs) in rats fed diet contaminated with toxigenic Fusarium verticillioides culture material. Rats were exposed for one week to FBs-free diet, FBs-contaminated diet containing 6 or 20 microg/g FB1 + FB2 and the same FBs-contaminated diet added of 20 mg/g cholestyramine. The increase of sphinganine/sphingosine (SA/SO) ratio in urine and kidney of treated rats was used as specific and sensitive biomarker of fumonisin exposure. The addition of cholestyramine to the FBs-contaminated diets consistently reduced the effect of FBs by reducing significantly (P < 0.05) both urinary and renal SA/SO ratios.
Chericoni, S; Stefanelli, F; Iannella, V; Giusiani, M
2014-02-15
Opiates play a relevant role in forensic toxicology and their assay in urine or blood is usually performed for example in workplace drug-testing or toxicological investigation of drug impaired driving. The present work describes two new methods for detecting morphine, codeine and 6-monoacethyl morphine in human urine or blood using a single step derivatisation in aqueous phase. Propyl chloroformate is used as the dramatizing agent followed by liquid-liquid extraction and gas-chromatography-mass spectroscopy to detect the derivatives. The methods have been validated both for hydrolysed and unhydrolysed urine. For hydrolysed urine, the LOD and LOQ were 2.5ng/ml and 8.5ng/ml for codeine, and 5.2ng/ml and 15.1ng/ml for morphine, respectively. For unhydrolysed urine, the LOD and LOQ were 3.0ng/ml and 10.1ng/ml for codeine, 2.7ng/ml and 8.1ng/ml for morphine, 0.8ng/ml and 1.5ng/ml for 6-monoacetyl morphine, respectively. In blood, the LOD and LOQ were 0.44ng/ml and 1.46ng/ml for codeine, 0.29ng/ml and 0.98ng/ml for morphine, 0.15ng/ml and 0.51ng/ml for 6-monoacetyl morphine, respectively. The validated methods have been applied to 50 urine samples and 40 blood samples (both positive and negative) and they can be used in routine analyses. Copyright © 2013 Elsevier B.V. All rights reserved.
Vorst, Keith L; Todd, Ewen C D; Rysert, Elliot T
2004-10-01
Four sampling devices, a sterile environmental sponge (ES), a sterile cotton-tipped swab (CS), a sterile calcium alginate fiber-tipped swab (CAS), and a one-ply composite tissue (CT), were evaluated for quantitative recovery of Listeria monocytogenes from a food-grade stainless steel surface. Sterile 304-grade stainless steel plates (6 by 6 cm) were inoculated with approximately 106 CFU/cm2 L. monocytogenes strain Scott A and dried for 1 h. The ES and CT sampling devices were rehydrated in phosphate buffer solution. After plate swabbing, ES and CT were placed in 40 ml of phosphate buffer solution, stomached for 1 min and hand massaged for 30 s. Each CS and CAS device was rehydrated in 0.1% peptone before swabbing. After swabbing, CS and CAS were vortexed in 0.1% peptone for 1 min. Samples were spiral plated on modified Oxford agar with modified Oxford agar Rodac Contact plates used to recover any remaining cells from the stainless steel surface. Potential inhibition from CT was examined in both phosphate buffer solution and in a modified disc-diffusion assay. Recovery was 2.70, 1.34, and 0.62 log greater using CT compared with ES, CS, and CAS, respectively, with these differences statistically significant (P < 0.001) for ES and CT and for CAS, CS, and CT (P < 0.05). Rodac plates were typically overgrown following ES, positive after CS and CAS, and negative after CT sampling. CT was noninhibitory in both phosphate buffer solution and the modified disc-diffusion assay. Using scanning electron microscopy, Listeria cells were observed on stainless steel plates sampled with each sampling device except CT. The CT device, which is inexpensive and easy to use, represents a major improvement over other methods in quantifying L. monocytogenes on stainless steel surfaces and is likely applicable to enrichment of environmental samples.
Ammonium detection by formation of colored zebra-bands in a detecting tube.
Hori, Tatsuaki; Niki, Keizou; Kiso, Yoshiaki; Oguchi, Tatsuo; Kamimoto, Yuki; Yamada, Toshiro; Nagai, Masahiro
2010-06-15
Ammonium ion was colorized by means of a diazo coupling reaction with 2-phenylphenol, where the color development reaction was conducted within 3min by using boric acid as a catalyst. The resulting colored solution (0.5ml) was supplied by suction to a detecting tube consisting of a nonwoven fabric test strip (2mm wide, 1mm thick, 150mm long) impregnated with benzylcetyldimethylammonium chloride in a stripe pattern and enclosed in a heat-shrinkable tube. When the colored solution was supplied to the detecting tube, blue zebra-bands formed, and the ammonium concentration was determined by counting the number of zebra-bands. The detection range was 1-20mg-Nl(-1). Ammonium ion in actual domestic wastewater samples was successfully detected by means of this method.
Gomez-Barrena, Enrique; Ortega-Andreu, Miguel; Padilla-Eguiluz, Norma G; Pérez-Chrzanowska, Hanna; Figueredo-Zalve, Reyes
2014-12-03
Abundant literature regarding the use of intravenous tranexamic acid (TXA) in primary total knee replacement is available. Randomized controlled trials have confirmed the efficacy of topical TXA compared with placebo, but the comparison between topical and intravenous TXA is unclear. The present study was designed to verify noninferior efficacy and safety of topical intra-articular TXA compared with intravenous TXA in primary total knee replacement with cemented implants. A Phase-III, single-center, double-blind, randomized, controlled clinical trial was performed to compare topical intra-articular TXA (3 g of TXA in 100 mL of physiological saline solution) with two intravenous doses of TXA (15 mg/kg in 100 mL of physiological saline solution, one dose before tourniquet release and another three hours after surgery) in a multimodal protocol for blood loss prevention. The primary outcome was the blood transfusion rate, and the secondary outcomes included visible blood loss (as measured in the drain) at twenty-four hours postoperatively and invisible blood loss (as estimated from the Nadler formula) at forty-eight hours postoperatively. The sample size of seventy-eight patients was calculated to give a statistical power of 99% for demonstrating noninferiority. Thirty-nine patients each were allocated to receive topical intra-articular TXA (the experimental group) and intravenous TXA (the control group); there were no significant differences in demographics or preoperative laboratory values between the groups. Noninferiority was estimated by comparing the confidence intervals with a delta of 10%. Student t and Mann-Whitney tests were used to assess the significance of any differences. The transfusion rate was zero in both groups; thus, noninferiority was demonstrated for the primary efficacy end point, suggesting equivalence. Noninferiority was also demonstrated for the secondary efficacy end points. Drain blood loss at twenty-four hours was 315.6 mL (95% confidence interval [CI], 248.5 to 382.7 mL) in the experimental group and 308.1 mL (95% CI, 247.6 to 368.5 mL) in the control group (p = 0.948, Mann-Whitney). Also, estimated blood loss at forty-eight hours was 1259.0 mL (95% CI, 1115.6 to 1402.3 mL) in the experimental group and 1317.9 mL (95% CI, 1175.4 to 1460.4 mL) in the control group (p = 0.837, Mann-Whitney). No significant safety differences were seen between groups. Topical administration of TXA according to the described protocol demonstrated noninferiority compared with intravenous TXA, with no safety concerns. This randomized controlled trial supports the topical intra-articular administration of TXA in primary total knee replacement with cemented implants. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
[Anesthesia for cesarean section in a patient with transient diabetes insipidus].
Amano, Asako; Mitsuse, Tetsuro; Hashiguchi, Akira; Masuda, Kazuyuki; Jo, Yoshitaka; Akasaka, Takefumi; Ogata, Shinya; Sato, Toshihide
2003-02-01
A 32-year-old pregnant female was admitted to our hospital at 32 week gestation and was scheduled for emergent cesarean section because of fetal distress. She had been suffering hydrodipsia and dry mouth, and had lost 4 kg in 2 weeks. Hypernatremia, hyperchloremia, and lower urinary specific gravity were preoperatively noted. Her electrolyte imbalance was partially corrected by the infusion of 1400 ml of 5% glucose solution and 500 ml of acetated Ringer's solution, but unexpected hyperglycemia; 440 mg.dl-1, appeared before surgery. Cesarean section was successfully performed with spinal anesthesia. A 1566 g male infant was delivered with 1 and 5 min Apgar scores of 2 and 1. Hyperglycemia and secondary hypoglycemia occurred in the infant in the neonatal ICU. The mother's fluid loss, including blood and amniotic fluid, was estimated at 784 ml. Five hundred milliliters of acetated Ringer's solution and 1000 ml of half saline solution with 2.5% glucose were infused before delivery, followed by the glucose solution containing a low concentration of sodium after delivery. After surgery, high serum osmotic pressure and paradoxically low urinary osmotic pressure were found. The plasma antidiuretic hormone level was normal against the high serum osmotic pressure. The electrolyte imbalance and urinary osmotic pressure were improved by using I-deamino-8-d-arginine vasopressin, and DI was finally diagnosed. Hormonal therapy was discontinued on day 20, and the patient was discharged on day 21. Some pregnancies are complicated by transient DI. Anesthesiologists have to consider DI when a pregnant female has symptoms of dehydration and a significant electrolyte imbalance.
Chemical Stability of Telavancin in Elastomeric Pumps☆
Sand, Patrick; Aladeen, Traci; Kirkegaard, Paul; LaChance, Dennis; Slover, Christine
2015-01-01
Background VIBATIV is a once-daily, injectable lipoglycopeptide antibiotic approved in the U.S. for the treatment of hospital-acquired and ventilator-associated bacterial pneumonia (HABP/VABP) caused by susceptible isolates of Staphylococcus aureus when alternative treatments are not suitable. In addition, VIBATIV is approved in the U.S. for the treatment of adult patients with complicated skin & skin structure infections (cSSSI) caused by susceptible isolates of Gram-positive bacteria, including Staphylococcus aureus, both methicillin-susceptible (MSSA) and methicillin-resistant (MRSA) strains. Objective To evaluate the chemical stability of telavancin (Vibativ; Theravance Biopharma US, Inc, Northbrook, Illinois), a lipoglycopeptide antibiotic with activity against methicillin-resistant Staphylococcus aureus, in 2 types of elastomeric pumps, the Intermate Infusion System (Baxter International Inc) and the Homepump Eclipse (I-Flow Corporation). Methods Different sizes of the Baxter (Ontario, Canada) (105 mL and 275 mL) and I-Flow (Stoughton, Massachusetts) (100 mL and 250 mL) pumps were compared with glass controls. The telavancin drug product was reconstituted and diluted to concentrations of 0.6 mg/mL and 8.0 mg/mL using either 0.9% saline, 5% dextrose in water, or sterilized water for injection (0.6 mg/mL telavancin) or saline (8.0 mg/mL telavancin) followed by Ringer’s Lactate solution. Pumps were filled and stored at 2°C to 8°C, protected from light. Aliquots from both pump types and for all telavancin reconstitution/dilution schemes and concentrations were taken over a period of 8 days and analyzed for appearance, pH, telavancin concentration and purity, and degradation products. Results The pH of all pump solutions remained consistent throughout the 8-day analysis period, within a range of 4.6 to 5.7 for the 0.6 mg/mL and 4.4 to 4.9 for the 8.0 mg/mL telavancin solutions. There was no significant change in the chromatographic purity for any of the pump solutions examined. All decreases in telavancin concentration were ≤2.7%. Comparison of each test sample solution to the corresponding glass control indicated no loss of active drug due to absorption by the elastomeric material of the pumps. The greatest increase in the amount of total degradants observed over the 8-day period was ~0.7 w/w%. Conclusions The results of this study indicate that telavancin remains chemically stable when diluted in the Intermate Infusion System and the Homepump Eclipse elastomeric pumps and stored at 2°C to 8°C for up to 8 days protected from light at the concentration range and dilution schemes evaluated. PMID:26649079
Repeat testing of low-level HIV-1 RNA: assay performance and implementation in clinical trials.
White, Kirsten; Garner, Will; Wei, Lilian; Eron, Joseph J; Zhong, Lijie; Miller, Michael D; Martin, Hal; Plummer, Andrew; Tran-Muchowski, Cecilia; Lindstrom, Kim; Porter, James; Piontkowsky, David; Light, Angela; Reiske, Heinz; Quirk, Erin
2018-05-15
Assess the performance of HIV-1 RNA repeat testing of stored samples in cases of low-level viremia during clinical trials. Prospective and retrospective analysis of randomized clinical trial samples and reference standards. To evaluate assay variability of the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test, v2.0, three separate sources of samples were utilized: the World Health Organization (WHO) HIV reference standard (assayed using 50 independent measurements at six viral loads <200 copies/ml), retrospective analysis of four to six aliquots of plasma samples from four clinical trial participants, and prospective repeat testing of 120 samples from participants in randomized trials with low-level viremia. The TaqMan assay on the WHO HIV-1 RNA standards at viral loads <200 copies/ml performed within the expected variability according to assay specifications. However, standards with low viral loads of 36 and 18 copies/ml reported values of ≥ 50 copies/ml in 66 and 18% of tests, respectively. In participants treated with antiretrovirals who had unexpected viremia of 50-200 copies/ml after achieving <50 copies/ml, retesting of multiple aliquots of stored plasma found <50 copies/ml in nearly all cases upon retesting (14/15; 93%). Repeat testing was prospectively implemented in four clinical trials for all samples with virologic rebound of 50-200 copies/ml (n = 120 samples from 92 participants) from which 42% (50/120) had a retest result of less than 50 copies/ml and 58% (70/120) retested ≥ 50 copies/ml. The TaqMan HIV-1 RNA assay shows variability around 50 copies/ml that affects clinical trial results and may impact clinical practice. In participants with a history of viral load suppression, unexpected low-level viremia may be because of assay variability rather than low drug adherence or true virologic failure. Retesting a stored aliquot of the same sample may differentiate between assay variability and virologic failure as the source of viremia. This retesting strategy could save time, money, and anxiety for patients and their providers, as well as decrease follow-up clinic visits without increasing the risk of virologic failure and resistance development.
Automated cellular sample preparation using a Centrifuge-on-a-Chip.
Mach, Albert J; Kim, Jae Hyun; Arshi, Armin; Hur, Soojung Claire; Di Carlo, Dino
2011-09-07
The standard centrifuge is a laboratory instrument widely used by biologists and medical technicians for preparing cell samples. Efforts to automate the operations of concentration, cell separation, and solution exchange that a centrifuge performs in a simpler and smaller platform have had limited success. Here, we present a microfluidic chip that replicates the functions of a centrifuge without moving parts or external forces. The device operates using a purely fluid dynamic phenomenon in which cells selectively enter and are maintained in microscale vortices. Continuous and sequential operation allows enrichment of cancer cells from spiked blood samples at the mL min(-1) scale, followed by fluorescent labeling of intra- and extra-cellular antigens on the cells without the need for manual pipetting and washing steps. A versatile centrifuge-analogue may open opportunities in automated, low-cost and high-throughput sample preparation as an alternative to the standard benchtop centrifuge in standardized clinical diagnostics or resource poor settings.
Clark, Melanie L.; Gamper, Merry E.
2003-01-01
A synoptic study of fecal-indicator bacteria was conducted during June and July 2000 in the Wind River, Bighorn River, and Goose Creek Basins in Wyoming as part of the U.S. Geological Survey's National Water-Quality Assessment Program for the Yellowstone River Basin. Fecal-coliform concentrations ranged from 2 to 3,000 col/100 mL (colonies per 100 milliliters) for 100 samples, and Escherichia coli concentrations ranged from 1 to 2,800 col/100 mL for 97 samples. Fecal-coliform concentrations exceeded the U.S. Environmental Protection Agency's recommended limit for a single sample for recreational contact with water in 37.0 percent of the samples. Escherichia coli concentrations exceeded the U.S. Environmental Protection Agency's recommended limit for a single sample for moderate use, full-body recreational contact with water in 38.1 percent of the samples and the recommended limit for infrequent use, full-body recreational contact with water in 24.7 percent of the samples. Fecal-indicator-bacteria concentrations varied by basin. Samples from the Bighorn River Basin had the highest median concentrations for fecal coliform of 340 col/100 mL and for Escherichia coli of 300 col/100 mL. Samples from the Wind River Basin had the lowest median concentrations for fecal coliform of 50 col/100 mL and for Escherichia coli of 62 col/100 mL. Fecal-indicator-bacteria concentrations varied by land cover. Samples from sites with an urban land cover had the highest median concentrations for fecal coliform of 540 col/100 mL and for Escherichia coli of 420 col/100 mL. Maximum concentrations for fecal coliform of 3,000 col/100 mL and for Escherichia coli of 2,800 col/100 mL were in samples from sites with an agricultural land cover. The lowest median concentrations for fecal coliform of 130 col/100 mL and for Escherichia coli of 67 col/100 mL were for samples from sites with a forested land cover. A strong and positive relation existed between fecal coliform and Escherichia coli (Spearman's Rho value of 0.976). The majority of the fecal coliforms were Escherichia coli during the synoptic study. Fecal-indicator-bacteria concentrations were not correlated to streamflow, water temperature, dissolved oxygen, pH, specific conduc-tance, and alkalinity. Fecal-indicator-bacteria concentrations were moderately correlated with turbidity (Spearman's Rho values of 0.662 and 0.640 for fecal coliform and Escherichia coli, respectively) and sediment (Spearman's Rho values of 0.628 and 0.636 for fecal coliform and Escherichia coli, respectively). Escherichia coli isolates analyzed by discriminant analysis of ribotype patterns for samples from the Bighorn River at Basin, Wyoming, and Bitter Creek near Garland, Wyoming, in the Bighorn River Basin were determined to be from nonhuman and human sources. Using a confidence interval of 90 percent, more of the isolates from both sites were classified as being from nonhuman than human sources; however, both samples had additional isolates that were classified as unknown sources. --------------------------------------------------------------------------------
Tang, Liang; Kwon, Hyun J; Kang, Kyung A
2004-12-30
Protein C (PC) is an important anticoagulant in human blood plasma, and early diagnosis of PC deficiency is critical for preventing dangerous thromboembolic complications. A fiber-optic PC immuno-biosensor has been under development in our research group for real-time PC-deficiency diagnosis. The sensor has demonstrated a good sensitivity and specificity for quantifying PC in buffered solutions. However, for plasma samples, with a limited sample reaction time, the sensor produced only 30% of the signal intensity of PC in buffer. The high plasma viscosity (1.9 cP) was speculated as the major reason for signal intensity reduction. In this investigation, the sensing performance of the fiber-optic PC biosensor is systematically characterized in terms of physical and chemical properties of the sample media. Theoretical and experimental analyses indicate that the reduced diffusion rate of PC molecules in viscous samples caused the sensing system to be more mass-transfer-limited. Convective flow of sample/reagent solutions during immunoreactions can increase the rate of the analyte mass transport from the bulk solution to the sensor surface, with reaction kinetics changing from mass-transfer-limited to reaction-limited as flow velocity increases. It was shown that PC sensor performance was significantly improved for plasma samples with convection. The effect of the flow velocity and incubation times for samples and reagents on the sensor performance was also systematically analyzed to optimize the assay protocol for PC sensing. Currently, a 6-cm-long immuno-biosensor is capable of quantifying PC in plasma (1 mL) in the heterozygous PC deficiency range (0.5 to 2.5 microg/mL) within 5 minutes, at an average signal-to-noise ratio of 50. 2004 Wiley Periodicals, Inc.
Finete, Virginia de Lourdes Mendes; Gouvêa, Marcos Martins; Marques, Flávia Ferreira de Carvalho; Netto, Annibal Duarte Pereira
2014-06-01
Experimental studies of the natural photoluminescence of melamine in aqueous solutions showed that its fluorescence intensity (at 250/365 nm) was appropriated for analytical purposes. The exploitation of such melamine property provided the basis of development of a new, simple, precise and accurate method based on high performance liquid chromatography with fluorescence detection (HPLC-Fluo) to determine melamine in kitchen plastic ware following aqueous extraction using a microwave oven. Optimization of analytical parameters such as solvent composition, pH and extraction conditions led to limits of detection and quantification of melamine of 0.0081 and 0.027 μg mL(-1), respectively, with a linear range up to 10 μg mL(-1). Sample extracts fortified with melamine at three concentration levels produced an average recovery of 98±6%, which was in agreement with the results achieved with a reference HPLC-UV method. Different samples of kitchen plastic ware analyzed by the developed and optimized method showed melamine concentrations in the aqueous extract up to 17 µg mL(-1), which corresponded to 86.0 mg kg(-1) in these utensils. The results obtained indicate that the use of kitchen plastic ware made of melamine can contaminate food with this compound after heating in a microwave oven. Copyright © 2014. Published by Elsevier B.V.
Identification of odor volatile compounds and deodorization of Paphia undulata enzymatic hydrolysate
NASA Astrophysics Data System (ADS)
Chen, Deke; Chen, Xin; Chen, Hua; Cai, Bingna; Wan, Peng; Zhu, Xiaolian; Sun, Han; Sun, Huili; Pan, Jianyu
2016-12-01
Unfavorable fishy odour is an inevitable problem in aquatic products. In the present study, headspace solid-phase microextraction gas chromatography mass spectrometry (HS-SPME-GC-MS) analysis of volatiles from untreated samples and three deodorized samples (under the optimal conditions) of Paphia undulata enzymatic hydrolysate revealed that the compounds contributing to the distinctive odor were 1-octen-3-ol, n-hexanal, n-heptanal, 2,4-heptadienal, and 2,4-decadienal, whereas n-pentanal, n-octanal, n-octanol, benzaldehyde, 2-ethylfuran and 2-pentylfuran were the main contributors to the aromatic flavor. The deodorizing effects of activated carbon (AC) adsorption, yeast extract (YE) masking and tea polyphenol (TP) treatment on a P. undulata enzymatic hydrolysate were investigated using orthogonal experiments with sensory evaluation as the index. The following optimized deodorization conditions were obtained: AC adsorption (35 mg mL-1, 80°C, 40 min), YE masking (7 mg mL-1, 45°C, 30 min) and TP treatment (0.4 mg mL-1, 40°C, 50 min). AC adsorption effectively removed off-flavor volatile aldehydes and ketones. YE masking modified the odor profile by increasing the relative contents of aromatic compounds and decreasing the relative contents of aldehydes and ketones. The TP treatment was not effective in reducing the odor score, but it significantly reduced the relative content of aldehydes while increasing that of alkanes. It is also notable that TP effectively suppressed trimethylamine (TMA) formation in a P. undulate hydrolysate solution for a period of 72 h.
Zarejousheghani, Mashaalah; Fiedler, Petra; Möder, Monika; Borsdorf, Helko
2014-11-01
A novel approach for the selective extraction of organic target compounds from water samples has been developed using a mixed-bed solid phase extraction (mixed-bed SPE) technique. The molecularly imprinted polymer (MIP) particles are embedded in a network of silica gel to form a stable uniform porous bed. The capabilities of this method are demonstrated using atrazine as a model compound. In comparison to conventional molecularly imprinted-solid phase extraction (MISPE), the proposed mixed-bed MISPE method in combination with gas chromatography-mass spectrometry (GC-MS) analysis enables more reproducible and efficient extraction performance. After optimization of operational parameters (polymerization conditions, bed matrix ingredients, polymer to silica gel ratio, pH of the sample solution, breakthrough volume plus washing and elution conditions), improved LODs (1.34 µg L(-1) in comparison to 2.25 µg L(-1) obtained using MISPE) and limits of quantification (4.5 µg L(-1) for mixed-bed MISPE and 7.5 µg L(-1) for MISPE) were observed for the analysis of atrazine. Furthermore, the relative standard deviations (RSDs) for atrazine at concentrations between 5 and 200 µg L(-1) ranged between 1.8% and 6.3% compared to MISPE (3.5-12.1%). Additionally, the column-to-column reproducibility for the mixed-bed MISPE was significantly improved to 16.1%, compared with 53% that was observed for MISPE. Due to the reduced bed-mass sorbent and at optimized conditions, the total amount of organic solvents required for conditioning, washing and elution steps reduced from more than 25 mL for conventional MISPE to less than 2 mL for mixed-bed MISPE. Besides reduced organic solvent consumption, total sample preparation time of the mixed-bed MISPE method relative to the conventional MISPE was reduced from more than 20 min to less than 10 min. The amount of organic solvent required for complete elution diminished from 3 mL (conventional MISPE) to less than 0.4 mL with the mixed-bed technique shows its inherent potential for online operation with an analytical instrument. In order to evaluate the selectivity and matrix effects of the developed mixed-bed MISPE method, it was applied as an extraction technique for atrazine from environmental wastewater and river water samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Savoie, Félix A; Asselin, Audrey; Goulet, Eric D B
2016-10-01
Savoie, FA, Asselin, A, and Goulet, EDB. Comparison of sodium chloride tablets-induced, sodium chloride solution-induced, and glycerol-induced hyperhydration on fluid balance responses in healthy men. J Strength Cond Res 30(10): 2880-2891, 2016-Sodium chloride solution-induced hyperhydration (NaCl-SolIH) is a powerful strategy to increase body water before exercise. However, NaCl-SolIH is associated with an unpleasant salty taste, potentially dissuading some athletes from using it and coaches from recommending it. Therefore, we evaluated the hyperhydrating potential of sodium chloride tablets-induced hyperhydration (NaCl-TabIH), which bypasses the palatability issue of NaCl-SolIH without sacrificing sodium chloride content, and compared it to NaCl-SolIH and glycerol-induced hyperhydration (GIH). Sixteen healthy males (age: 21 ± 2 years; fat-free mass (FFM): 65 ± 6 kg) underwent three, 3-hour long passive hyperhydration protocols during which they drank, over the first 60 minutes, 30-ml·kg FFM of an artificially sweetened solution. During NaCl-TabIH, participants swallowed 7.5, 1 g each, sodium chloride tablets with every liter of solution. During NaCl-SolIH, an equal quantity of sodium chloride tablets was dissolved in each liter of solution. With GIH, the glycerol concentration was 46.7 g·L. Urine production, fluid retention, hemoglobin, hematocrit, plasma volume, and perceptual variables were monitored throughout the trials. Total fluid intake was 1948 ± 182 ml. After 3 hour, there were no significant differences among treatments for hemoglobin, hematocrit, and plasma volume changes. Fluid retention was significantly greater with NaCl-SolIH (1150 ± 287 ml) than NaCl-TabIH (905 ± 340 ml) or GIH (800 ± 211 ml), with no difference between NaCl-TabIH and GIH. No differences were found among treatments for perceptual variables. NaCl-TabIH and GIH are equally effective, but inferior than NaCl-SolIH. NaCl-TabIH represents an alternative to hyperhydration induced with glycerol, which is prohibited by the World Anti-Doping Agency.
2008-12-01
n-propoxide and titanium isopropoxide , were measured with a graduated auto pipet and combined with 45 mL of 2-MOE in a 125 mL flask. The solution...nitrogen (N2). This anneal procedure was used to remove trapped hydrogen from the thin film. Following the anneal, a bi-layer of titanium (Ti) and...dioxide Ti titanium 10 NO. OF COPIES ORGANIZATION 1 ADMNSTR ELEC DEFNS TECHL INFO CTR ATTN DTIC OCP 8725 JOHN J KINGMAN RD STE
Bogusz, Maciej J; Enazi, Eid Al; Hassan, Huda; Abdel-Jawaad, Jamil; Ruwaily, Jamal Al; Tufail, Mohammed Al
2007-05-01
The purpose of the study was to develop rapid and simple procedure for simultaneous determination of cyclosporine A (CsA), tacrolimus (TCR), and sirolimus (SIR) in whole blood and mycophenolic acid (MPA) in plasma. Ascomycin (ASCO), cyclosporine D (CsD), and desmethoxysirolimus (DMSIR) were used as internal standards (IS) for TCR, CsA and MPA, and SIR, respectively. In the method development, six-level blood calibrators were used for CsA (range 47-1725 ng/ml), TCR (range 2.1-38.8 ng/ml), and SIR (range 2.4-39.6 ng/ml). Four-level calibrators were used for MPA (range 0.15-5.48 microg/ml). Four levels of quality control (QC) standards were used for blood samples, together with two levels of QC standards in plasma. All QC standards and calibrators were obtained from commercial sources. Sample preparation based on precipitation of 50 microl of sample in zinc sulfate-methanol-acetonitrile mixture containing IS, followed by centrifugation. HPLC was performed on ChromSpher pi column, 30 mm x 3 mm, in ballistic gradient of ammonium formate buffer-methanol at 0.8 ml flow rate. Following gradient elution profile was applied: 0-1.2 min at 30% methanol (divert valve to waste), 1.21-3.1 min 97% methanol (divert valve to detector), 3.11-3.7 min 30% methanol (divert valve to waste). ESI-MS-MS (MRM) was done on TSQ Quantum instrument with ESI source in positive ion mode. Ammoniated adducts of protonated molecules were used as precursor ions for all analytes but MPA. For this compound sodium adduct was used. Following transitions were monitored: for CsA m/z 1220-1203; for CsD 1234-1217; for SIR 931.6-864.5 and 882.6; for DMSIR 902-834.5; for TCR 821.5-768.5 and 785.5; for ASCO 809.5-756; for MPA 343-211.6; for MPA-glucuronide 514-306 and 211.6. The limits of quantitation were: 1 ng/ml for TCR and SIR, 20 ng/ml for CsA, and 0.1 microg/ml for MPA. Post-column infusion experiments showed that no positive or negative peaks appeared after injection of matrix in the elution range of target compounds. General signal suppression caused by matrix ranged from 20-40%, and was caused mainly by zinc sulfate present in deproteinizing solution. Extracted samples were stable for 2 days at 4 degrees C and for at least 20 days at -20 degrees C. MPA was fully separated from its glucuronide, which was eluted at around 0.7-0.8 min and directed to the waste. Some mutual cross-contribution of CsD and CsA was observed (below 1%), other IS did not contribute to target compounds and vice versa. Observations of chromatograms from patients taken single therapy demonstrated that possible metabolites of CsA, TCR, or SIR did not interfere with target compounds or IS.
Insa, S; Anticó, E; Ferreira, V
2005-09-30
A reliable solid-phase extraction (SPE) method for the simultaneous determination of 2,4,6-trichloroanisole (TCA) and 2,4,6-tribromoanisole (TBA) in wines has been developed. In the proposed procedure 50 mL of wine are extracted in a 1 mL cartridge filled with 50 mg of LiChrolut EN resins. Most wine volatiles are washed up with 12.5 mL of a water:methanol solution (70%, v/v) containing 1% of NaHCO3. Analytes are further eluted with 0.6 mL of dichloromethane. A 40 microL aliquot of this extract is directly injected into a PTV injector operated in the solvent split mode, and analysed by gas chromatography (GC)-ion trap mass spectrometry using the selected ion storage mode. The solid-phase extraction, including sample volume and rinsing and elution solvents, and the large volume GC injection have been carefully evaluated and optimized. The resulting method is precise (RSD (%) < 6% at 100 ng L(-1)), sensitive (LOD were 0.2 and 0.4 ng/L for TCA and TBA, respectively), robust (the absolute recoveries of both analytes are higher than 80% and consistent wine to wine) and friendly to the GC-MS system (the extract is clean, simple and free from non-volatiles).
In vitro antimicrobial efficacy of MTAD and sodium hypochlorite.
Shabahang, Shahrokh; Pouresmail, Manouchehr; Torabinejad, Mahmoud
2003-07-01
The purpose of this study was to compare the ability of a mixture of a tetracycline isomer, an acid, and a detergent (MTAD) with that of sodium hypochlorite (NaOCI) to disinfect human root canals that had been contaminated with whole saliva. One hundred and thirty-two root canals of extracted human teeth were cleaned and shaped using the passive step-back technique and rotary NiTi files. The smear layer was removed, and the teeth were autoclaved. Six autoclaved samples were transferred to sterile broth without contamination with saliva to serve as negative controls. Whole saliva was used to contaminate the root canals of the rest of the samples for 48 h. Six of these contaminated samples were irrigated with Brain Heart Infusion (BHI) broth and served as positive controls. The rest of the contaminated specimens were then divided into two experimental groups of 60 teeth each. In one group, the canals were irrigated with 1 ml MTAD, and the samples were immersed in 2 ml of the same solution for 5 min. In the second group, the specimens were similarly treated with 5.25% NaOCl. All samples were washed in BHI broth and then placed in another tube containing BHI broth and incubated for 96 h. Disinfection of the samples was determined based on presence or absence of turbidity in the broth 96 h later. Twenty-three of 60 teeth treated with NaOCl remained infected. Only one of 60 teeth treated with MTAD remained infected. Statistical analysis of the data using the Chi-square test showed a significant difference between the two groups (p < 0.0001).
21 CFR 522.810 - Embutramide, chloroquine, and lidocaine solution.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Embutramide, chloroquine, and lidocaine solution... ANIMAL DRUGS § 522.810 Embutramide, chloroquine, and lidocaine solution. (a) Specifications. Each milliliter (mL) of solution contains 135 milligrams (mg) embutramide; 45 mg chloroquine phosphate, U.S.P...
Filip, Miuţa; Vlassa, Mihaela; Coman, Virginia; Halmagyi, Adela
2016-05-15
A high performance liquid chromatography method with refractive index detection (HPLC-RI), for simultaneous determination of glucose, fructose, sucrose and sorbitol in leaf and/or apple peel samples from nine apple (Malus domestica Borkh.) cultivars and rootstocks, originating from a germplasm collection, has been developed and validated. Box-Behnken design of response surface methodology was applied for the method optimization. The Carbosep Coregel 87H3 column was used under the optimum conditions predicted: mobile phase of H2SO4 0.005 mol L(-1) solution, flow rate of 0.3 mL min(-1) and column temperature of 35°C. The method was validated for linearity (R(2)>0.99), limits of detection (2.67-4.83 μg mL(-1)) and quantification (8.9-16.1 μg mL(-1)), precision (%RSD<5.05) and recovery (93.94-103.06%) and satisfactory results obtained. The sugars content varied across micropropagated plants in vitro, plants regenerated after cryostorage, growing trees in vivo, and fruit peel. Copyright © 2015 Elsevier Ltd. All rights reserved.
Zehavi, D; Seiber, J N
1996-10-01
An analytical method has been developed for the determination of trace levels of trifluoroacetic acid (TFA), an atmospheric breakdown product of several of the hydrofluorocarbon (HFC) and hydrochlorofluorocarbon (HCFC) replacements for the chlorofluorocarbon (CFC) refrigerants, in water and air. TFA is derivatized to the volatile methyl trifluoroacetate (MTFA) and determined by automated headspace gas chromatography (HSGC) with electron-capture detection or manual HSGC using GC/MS in the selected ion monitoring (SIM) mode. The method is based on the reaction of an aqueous sample containing TFA with dimethyl sulfate (DMS) in concentrated sulfuric acid in a sealed headspace vial under conditions favoring distribution of MTFA to the vapor phase. Water samples are prepared by evaporative concentration, during which TFA is retained as the anion, followed by extraction with diethyl ether of the acidified sample and then back-extraction of TFA (as the anion) in aqueous bicarbonate solution. The extraction step is required for samples with a relatively high background of other salts and organic materials. Air samples are collected in sodium bicarbonate-glycerin-coated glass denuder tubes and prepared by rinsing the denuder contents with water to form an aqueous sample for derivatization and analysis. Recoveries of TFA from spiked water, with and without evaporative concentration, and from spiked air were quantitative, with estimated detection limits of 10 ng/mL (unconcentrated) and 25 pg/mL (concentrated 250 mL:1 mL) for water and 1 ng/m(3) (72 h at 5 L/min) for air. Several environmental air, fogwater, rainwater, and surface water samples were successfully analyzed; many showed the presence of TFA.
Soil Solution Phosphorus Status and Mycorrhizal Dependency in Leucaena leucocephala.
Habte, M; Manjunath, A
1987-04-01
A phosphorus sorption isotherm was used to establish concentrations of P in a soil solution ranging from 0.002 to 0.807 mug/ml. The influence of P concentration on the symbiotic interaction between the tropical tree legume Leucaena leucocephala and the vesicular-arbuscular mycorrhizal (VAM) fungus Glomus fasciculatum was evaluated in pot experiments. The level of mycorrhizal infection in Leucaena roots increased as the concentration of P was raised from 0.002 to 0.153 mug/ml. Higher levels of P depressed mycorrhizal infection, but the level of infection never declined below 50%. Periodic monitoring of P contents of Leucaena subleaflets indicated that significant mycorrhizal activity was detected as early as 17 days after planting, with the activity peaking 12 to 16 days thereafter. The highest level of mycorrhizal activity was associated with a soil solution P level of 0.021 mug/ml. Even though the mycorrhizal inoculation effect diminished as the concentration of P in the soil solution was increased, mycorrhizal inoculation significantly increased P uptake and dry-matter yield of Leucaena at all levels of soil solution P examined. The concentration of P required by nonmycorrhizal L. leucocephala for maximum yield was 27 to 38 times higher than that required by mycorrhizal L. leucocephala. The results illustrate the very high dependence of L. leucocephala on VAM fungi and the significance of optimizing soil solution phosphorus for enhancing the benefits of the VAM symbiosis.
ARMY GAS-COOLED REACTOR SYSTEMS PROGRAM. Quarterly Progress Report, October 1-December 31, 1963
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1964-02-15
The ML-1 power plant did not operate during the report period; low power reactor physics and shielding experiments were conducted with the ML-1 reactor. Evaluation of moderate corrosion observed on aluminum parts exposed to the ML-1 shield solution indicated no loss of performance capability. Preliminary tests showed that the corrosion probably was caused by heavy metal ions or chlorides in the solution, Massive corrosion observed on the ML-1 fuel element lower spiders was attributed to sub-standard material; failure of some spiders was attributed to a combination of corrosion and sub-standard fabrication. Evaluation indicated that the upper spiders will perform satisfactorilymore » for the design lifetime. Modification, repair, and reassembly of the CSN-1A t-c set was completed. Operation demonstrated bearing stability, but showed that the turbine effective flow area was too large. A bypass flow path in the turbine was being corrected. The TCS-670 t-c set will be stored indefinitely. Since a commercial alternator will be used for the ML-1A, further development of the brushless alternator was postponed indefinitely. Evaluation revealed that the ML-1 improved precooler design was not compatible with ML-1A requirements. Operntion of the IB-17R-2 and -3 test elements in the GETR continued without incident. Preliminary design of the ML-1A power plant was initiated. Design of modifications to the GCRE facility to adapt it to testing the ML-1 reactor skid was initiated. (auth)« less
Cao, Tian-Shu; Chi, Zhe; Liu, Guang-Lei; Chi, Zhen-Ming
2014-01-01
It has been reported that trehalose plays an important role in stress tolerance in yeasts. Therefore, in order to construct a stably recombinant Saccharomyces sp. W0 with higher ethanol tolerance, the TPS1 gene encoding 6-phosphate-trehalose synthase cloned from Saccharomycopsis fibuligera A11 was ligated into the 18S rDNA integration vector pMIRSC11 and integrated into chromosomal DNA of Saccharomyces sp. W0. The transformant Z8 obtained had the content of 6.23 g of trehalose/100 g of cell dry weight, while Saccharomyces sp. W0 only contained 4.05 g of trehalose/100 g of cell dry weight. The transformant Z8 also had higher ethanol tolerance (cell survival was 25.1 % at 18 ml of ethanol/100 ml of solution) and trehalose-6-phosphate synthase (Tps1) activity (1.3 U/mg) and produced more ethanol (16.4 ml of ethanol/100 ml of medium) than Saccharomyces sp. W0 (cell survival was 12.1 % at 18 ml of ethanol/100 ml of solution, Tps1 activity was 0.8 U/mg and the produced ethanol concentration was 14.2 ml of ethanol/100 ml of medium) under the same conditions. The results show that trehalose indeed can play an important role in ethanol tolerance and ethanol production by Saccharomyces sp. W0.
A novel polymer inclusion membranes based optode for sensitive determination of Al³⁺ ions.
Suah, Faiz Bukhari Mohd; Ahmad, Musa; Heng, Lee Yook
2015-06-05
A novel approach for the determination of Al(3+) from aqueous samples was developed using an optode membrane produced by physical inclusion of Al(3+) selective reagent, which is morin into a plasticized poly(vinyl chloride). The inclusion of Triton X-100 was found to be valuable and useful for enhancing the sorption of Al(3+) ions from liquid phase into the membrane phase, thus increasing the intensity of optode's absorption. The optode showed a linear increase in the absorbance at λ(max)=425 nm over the concentration range of 1.85×10(-6)-1.1×10(-4) mol L(-1) (0.05-3 μg mL(-1)) of Al(3+) ions in aqueous solution after 5 min. The limit of detection was determined to be 1.04×10(-6) mol L(-1) (0.028 μg mL(-1)). The optode developed in the present work was easily prepared and found to be stable, has good mechanical strength, sensitive and reusable. In addition, the optode was tested for Al(3+) determination in lake water, river water and pharmaceutical samples, which the result was satisfactory. Copyright © 2015 Elsevier B.V. All rights reserved.
Potential application of Northern Argentine propolis to control some phytopathogenic bacteria.
Ordóñez, R M; Zampini, I C; Moreno, M I Nieva; Isla, M I
2011-10-20
The antimicrobial activity of samples of Northern Argentine propolis (Tucumán, Santiago del Estero and Chaco) against phytopathogenic bacteria was assessed and the most active samples were identified. Minimal inhibitory concentration (MIC) values were determined by agar macrodilution and broth microdilution assays. Strong antibacterial activity was detected against Erwinia carotovora spp carotovora CECT 225, Pseudomonas syringae pvar tomato CECT 126, Pseudomonas corrugata CECT 124 and Xanthomonas campestris pvar vesicatoria CECT 792. The most active propolis extract (Tucumán, T1) was selected to bioguide isolation and identified for antimicrobial compound (2',4'-dihydroxychalcone). The antibacterial chalcone was more active than the propolis ethanolic extract (MIC values of 0.5-1 μg ml(-1) and 9.5-15 μg ml(-1), respectively). Phytotoxicity assays were realized and the propolis extracts did not retard germination of lettuce seeds or the growth of onion roots. Propolis solutions applied as sprays on tomato fruits infected with P. syringae reduced the severity of disease. Application of the Argentine propolis extracts diluted with water may be promising for the management of post harvest diseases of fruits. Copyright © 2010 Elsevier GmbH. All rights reserved.
Cajamarca, Fabio Antonio Suquila; Corazza, Marcela Zanetti; Prete, Maiyara Caroline; Dragunski, Douglas Cardoso; Rocker, Cristiana; Caetano, Josiane; Gonçalves Júnior, Affonso Celso; Tarley, César Ricardo Teixeira
2016-12-01
In this study, a new method for the preconcentration of cadmium ions using modified aquatic macrophytes - Salvinia molesta as biosorbent in an on-line preconcentration system coupled to flame atomic absorption spectrometry (FAAS) was developed. The method is based on preconcentration of 20.0 mL sample at pH 3.75 through 35.0 mg of biosorbent at 10.0 mL min -1 and subsequent elution with 0.5 mol L -1 HNO 3 . A preconcentration factor of 31-fold, linear dynamic range from 5.0 to 70.0 µg L -1 (r = 0.9996) and detection and quantification limits of 0.15 and 0.51 µg L -1 were obtained. The characterization of the biosorbent chemically modified with NaOH and citric acid, was performed through FTIR and SEM measurements. The method precision was found to be 3.97 % and 1.48 % for 5.0 and 60.0 µg L -1 Cd(II) solutions, respectively. The applicability of method was checked by analysis of different kind of water samples and certified reference material.
Separation of arsenic(III) and arsenic(V) in ground waters by ion-exchange
Ficklin, W.H.
1983-01-01
The predominant species of arsenic in ground water are probably arsenite and arsenate. These can be separated with a strong anion-exchange resin (Dowex 1 ?? 8; 100-200 mesh, acetate form) in a 10 cm ?? 7 mm column. Samples are filtered and acidified with concentrated hydrochloric acid (1 ml per 100 ml of sample) at the sample site. Five ml of the acidified sample are used for the separation. At this acidity, As(III) passes through the acetate-form resin, and As(V) is retained. As(V) is eluted by passage of 0.12M hydrochloric acid through the column (resulting in conversion of the resin back into the chloride form). Samples are collected in 5-ml portions up to a total of 20 ml. The arsenic concentration in each portion is determined by graphite-furnace atomic-absorption spectrophotometry. The first two fractions give the As(III) concentration and the last two the As(V) concentration. The detection limit for the concentration of each species is 1 ??g l. ?? 1983.
NASA Astrophysics Data System (ADS)
Rezayi, Majid; Karazhian, Reza; Abdollahi, Yadollah; Narimani, Leila; Sany, Seyedeh Belin Tavakoly; Ahmadzadeh, Saeid; Alias, Yatimah
2014-04-01
The introduction of low detection limit ion selective electrodes (ISEs) may well pave the way for the determination of trace targets of cationic compounds. This research focuses on the detection of titanium (III) cation using a new PVC-membrane sensor based on synthesized tris(2pyridyl) methylamine (tpm) ionophore. The application and validation of the proposed sensor was done using potentiometric titration, inductively coupled plasma atomic emission spectrometry (ICP-AES), and atomic absorption spectrometry (AAS). The membrane sensor exhibited a Nernstian response to the titanium (III) cation over a concentration range of 1.0 × 10-6-1.0 × 10-2 M and pH range from 1-2.5. The Nernstian slope, the lower of detection (LOD), and the response time (t95%) of the proposed sensor were 29.17 +/- 0.24 mV/dec, 7.9 × 10-7 M, and 20 s, respectively. The direct determination of 4-39 μg/ml of titanium (III) standard solution showed an average recovery of 94.60 and a mean relative standard deviation of 1.8 at 100.0 μg/ml. Finally, the utilization of the electrodes as end-point indicators for potentiometric titration with EDTA solutions for titanium (III) sensor was successfully carried out.
Wehr, J Bernhard; Blamey, F Pax C; Menzies, Neal W
2010-04-28
The determination of the cation exchange capacity (CEC) of plant cell walls is important for many physiological studies. We describe the determination of cell wall CEC by cation binding, using either copper (Cu) or lanthanum (La) ions, and by colorimetry. Both cations are strongly bound by cell walls, permitting fast and reproducible determinations of the CEC of small samples. However, the dye binding methods using two cationic dyes, Methylene Blue and Toluidine Blue, overestimated the CEC several-fold. Column and centrifugation methods are proposed for CEC determination by Cu or La binding; both provide similar results. The column method involves packing plant material (2-10 mg dry mass) in a chromatography column (10 mL) and percolating with 20 bed volumes of 1 mM La or Cu solution, followed by washing with deionized water. The centrifugation method uses a suspension of plant material (1-2 mL) that is centrifuged, and the pellet is mixed three times with 10 pellet volumes of 1 mM La or Cu solution followed by centrifugation and final washing with deionized water. In both methods the amount of La or Cu bound to the material was determined by spectroscopic methods.
Mohan, Rayapudi Phani; Pai, Annappa Raghavendra Vivekananda
2015-01-01
The aim was to assess the influence of two irrigation regimens having ethylenediaminetetraacetic acid (EDTA) and ethylenediaminetetraacetic acid with cetrimide (EDTAC) as final irrigants, respectively, on the dentine wettability for AH Plus sealer by comparing its contact angle formed to the irrigated dentine. Study samples were divided into two groups (n = 10). The groups were irrigated with 3% sodium hypochlorite (NaOCl) solution followed by either 17% EDTA or 17% EDTAC solution. AH Plus was mixed, and controlled volume droplet (0.1 mL) of the sealer was placed on the dried samples. The contact angle was measured using a Dynamic Contact Angle Analyzer and results were analyzed using SPSS 21.0 and 2 sample t-test. There was a significant difference in the contact angle of AH Plus formed to the dentine irrigated with the above two regimens. AH Plus showed significantly lower contact angle with the regimen having EDTAC as a final irrigant than the one with EDTA (P < 0.05). An irrigation regimen consisting of NaOCl with either EDTA or EDTAC solution as a final irrigant influences the dentine wettability and contact angle of a sealer. EDTAC as a final irrigant facilitates better dentin wettability than EDTA for AH Plus to promote its better flow and adhesion.
Alekish, Myassar O; Ismail, Zuhair B; Awawdeh, Mofleh S; Shatnawi, Shoroq
2017-08-01
The aims of this study were to evaluate the effects of intramammary infusion of sage ( Salvia officinalis ) essential oil (EO) on milk somatic cell count (SCC), milk composition parameters and selected hematology and serum biochemical parameters in 20 Awassi ewes affected with subclinical mastitis. The dried leaves of sage were used to extract the EO by hydrodistillation. The minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) of sage EO against Staphylococcus aureus were determined by the broth dilution method. Ewes were divided randomly into three main groups and received one of the following treatments; Group 1 (n=5): Dimethyl sulfoxide (DMSO) alone (5 ml; 0.2 ml of DMSO in 4.8 ml of saline), Group 2 (n=5): Amoxicillin alone (3 ml), and Group 3 (n=10): Sage EO (5 ml of sage EO solution [0.2 ml DMSO+1 ml EO+3.8 ml sterile saline]). All treatments were administered by intramammary infusion into each teat twice per day for 3 consecutive days. Milk samples for SCC and milk components determination and whole blood samples for hematology and serum biochemical analyses were collected before treatment (T0) and at 24 (T24) and 48 (T48) h after the last treatment. The MIC and MBC of sage EO against S. aureus were 12.5% and 6.1%, respectively. SCC was decreased significantly (p<0.05) at T24 and T48 h in sage EO and amoxicillin treated groups. Milk fat and lactose were increased significantly (p<0.05) in sage EO and amoxicillin treated ewes while no significant changes were observed in the percentages of solids-not-fat, protein and total solids. No significant effects of sage EO treatment on any of the hematology or serum biochemical parameters were observed. There were no local or systemic side effects observed in any of the treated ewes. However, further clinical trials are warranted to determine safety and possible withdrawal times in milk before its recommendation for use in organic operations. In this study, the intramammary infusion of sage EO to ewes affected with subclinical mastitis resulted in a significant decrease in SCC 24 h and 48 h posttreatment. In addition, milk fat and lactose were increased in animals that received the EO as well as in those treated with the antibiotic.
Nojavan, Saeed; Asadi, Sakine
2016-02-01
Simultaneous extraction of acidic and basic analytes from a sample is seen to be a challenging task. In this work, a novel and efficient electromembrane extraction (EME) method based on two separate cells was applied to simultaneously extract and preconcentrate two acidic drugs (naproxen and ibuprofen) along with a basic drug (ketamine). Once both cells were filled with the sample solution, basic drug was extracted from one cell with the other cell used to extract acidic drugs. The employed supported liquid membranes for the extraction of acidic and basic drugs were 2-ethyl hexanol and 1-octanol, respectively. Under an applied potential of 250 V in the course of the extraction process, acidic, and basic drugs were extracted from a 3.0 mL aqueous sample solution into 25 μL acceptor solutions. The pH values of the donor and acceptor solutions in the cathodic cell were 5.0 and 1.5, respectively, the corresponding values in the anodic cell were, however, 8.0 and 12.5, respectively. The rates of recovery obtained within 20 min of extraction time at a stirring rate of 750 rpm ranged from 45 to 54%. With correlation coefficients ranging from 0.990 to 0.996, the proposed EME technique provided good linearity over a concentration range of 20-1000 ng/mL. The LOD for all drugs was found to be 6.7 ng/mL, while reproducibility ranged from 7 to 12% (n = 5). Finally, applying the proposed method to determine and quantify the drugs in urine and wastewater samples, satisfactory results were achieved. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Kuusimäki, Leea; Peltonen, Kimmo; Vainiotalo, Sinikka
A previously introduced method for monitoring environmental tobacco smoke (ETS) was further validated. The method is based on diffusive sampling of a vapour-phase marker, 3-ethenylpyridine (3-EP), with 3 M passive monitors (type 3500). Experiments were done in a dynamic chamber to assess diffusive sampling in comparison with active sampling in charcoal tubes or XAD-4 tubes. The sampling rate for 3-EP collected on the diffusive sampler was 23.1±0.6 mL min -1. The relative standard deviation for parallel samples ( n=6) ranged from 4% to 14% among experiments ( n=9). No marked reverse diffusion of 3-EP was detected nor any significant effect of relative humidity at 20%, 50% or 80%. The diffusive sampling of 3-EP was validated in field measurements in 15 restaurants in comparison with 3-EP and nicotine measurements using active sampling. The 3-EP concentration in restaurants ranged from 0.01 to 9.8 μg m -3, and the uptake rate for 3-EP based on 92 parallel samples was 24.0±0.4 mL min -1. A linear correlation ( r=0.98) was observed between 3-EP and nicotine concentrations, the average ratio of 3-EP to nicotine being 1:8. Active sampling of 3-EP and nicotine in charcoal tubes provided more reliable results than sampling in XAD-4 tubes. All samples were analysed using gas chromatography-mass spectrometry after elution with a 15% solution of pyridine in toluene. For nicotine, the limit of quantification of the charcoal tube method was 4 ng per sample, corresponding to 0.04 μg m -3 for an air sample of 96 L. For 3-EP, the limit of quantification of the diffusive method was 0.5-1.0 ng per sample, corresponding to 0.04-0.09 μg m -3 for 8 h sampling. The diffusive method proved suitable for ETS monitoring, even at low levels of ETS.
Guohua, Xia; Pan, Ruirong; Bao, Rui; Ge, Yanru; Zhou, Cunshan; Shen, Yuping
2017-01-01
Sanghuang is one of mystical traditional Chinese medicines recorded earliest 2000 years ago, that included various fungi of Inonotus genus and was well-known for antitumor effect in modern medicine. Inonotus vaninii is grown in natural forest of Northeastern China merely and used as Sanghuang commercially, but it has no quality control specification until now. This study was to establish a rapid method of two-phase acid hydrolysis followed by reversed phase-high performance liquid chromatography-ultra violet (RP-HPLC-UV) to quantify naringenin in the fruit body of I. vaninii . Sample solution was prepared by pretreatment of raw material in two-phase acid hydrolysis and the hydrolysis technology was optimized. After reconstitution, analysis was performed using RP-HPLC-UV. The method validation was investigated and the naringenin content of sample and comparison were determined. The naringenin was obtained by two-phase acid hydrolysis method, namely, 10.0 g of raw material was hydrolyzed in 200 mL of 1% sulfuric acid aqueous solution (v/v) and 400 mL of chloroform in oil bath at 110°C for 2 h. Good linearity ( r = 0.9992) was achieved between concentration of analyte and peak area. The relative standard deviation (RSD) of precision was 2.47% and the RSD of naringenin contents for repeatability was 3.13%. The accuracy was supported with recoveries at 96.37%, 97.30%, and 99.31%. The sample solution prepared using the proposed method contained higher content of naringenin than conventional method and was stable for 8 h. Due to the high efficiency of sample preparation and high reliability of the HPLC method, it is feasible to use this method for routine analysis of naringenin in the fungus. A convenient two-phase acid hydrolysis was employed to produce naringenin from raw material, and then an efficient and reliable reversed phase-high performance liquid chromatography-ultra violet method was established to monitor naringenin in the fruit bodies of Inonotus vaninii . The newly established method could be used to control the quality of the herb. Abbreviations used: RP-HPLC-UV: Reversed Phase-High Performance Liquid Chromatography-Ultra Violet, RSD: Relative Standard Deviation, EtOAc: Ethyl acetate, ACN: Acetonitrile, MeOH: Methanol, RH: Relative Humility.
Kienen, Vanessa; Costa, Willian F; Visentainer, Jesuí V; Souza, Nilson E; Oliveira, Cláudio C
2008-03-15
A green chromatographic analytical method for determination of fat-soluble vitamins (A, E, D3 and K1) in food and pharmaceutical supplement samples is proposed. The method is based on the modification of a C18 column with a 3.00% (w/v) sodium dodecyl sulphate (SDS) aqueous solution at pH 7 (0.02 mol L(-1) phosphate buffer solution) and in the usage of the same surfactant solution as mobile phase with the presence of 15.0% (v/v) butyl alcohol as an organic solvent modifier. After the separation process, the vitamins are detected at 230 nm (K1, D3 and E), 280 nm (A, E, D3 and K1) and 300 nm (K1, D3 and E). The chromatographic procedure yielded precise results (better than 5%) and is able to run one sample in 25 min, consuming 1.5 g of SDS, 90 mg of phosphate and 7.5 mL of butyl alcohol. When the flow rate of the mobile phase is 2 mL min(-1) the retention times are 4.0, 9.6, 13.0 and 22.7 min for D3, A, E and K1 vitamins, respectively; and all peak resolutions are higher than 2. The analytical curves present the following linear equations: area=6290+34852 (vitamin A), R2=0.9998; area=4092+36333 (vitamin E), R2=0.9997; area=-794+30382 (vitamin D3) R2=0.9998 and area=-7175+82621 (vitamin K1), R2=0.9996. The limits of detection and quantification for vitamins A, E, D(3) and K(1) were estimated for a test pharmaceutical vitamin supplement sample as 0.81, 1.12, 0.91 and 0.83 mg L(-1) and 2.43, 3.36, 2.73 and 2.49, respectively. When the proposed method was applied to food and pharmaceutical sample analysis, precise results were obtained (R.S.D.<5% and n=3) and in agreement with those obtained by using the classical chromatographic method that uses methanol and acetonitrile as mobile phase. Here, the traditional usage of toxic organic solvent as mobile phase is avoided, which permits to classify the present method as green.
Richard, Justin T; Robeck, Todd R; Osborn, Steven D; Naples, Lisa; McDermott, Alexa; LaForge, Robert; Romano, Tracy A; Sartini, Becky L
2017-05-15
Steroid hormone analysis in blow (respiratory vapor) may provide a minimally invasive way to assess the reproductive status of wild cetaceans. Biological validation of the method is needed to allow for the interpretation of hormone measurements in blow samples. Utilizing samples collected from trained belugas (Delphinapterus leucas, n=20), enzyme immunoassays for testosterone and progesterone were validated for use with beluga blow samples. Testosterone concentrations in 40 matched blood and blow samples collected from 4 male belugas demonstrated a positive correlation (R 2 =0.52, p<0.0001). Progesterone concentrations in 64 matching blood and blow samples from 11 females were also positively correlated (R 2 =0.60, p<0.0001). Testosterone concentrations (mean±SD) in blow samples collected from adult males (119.3±14.2pg/ml) were higher (p<0.01) than that of a juvenile male (<8years) (59.4±6.5pg/ml) or female belugas (54.1±25.7pg/ml). Among adult males, testosterone concentrations in blow demonstrated a seasonal pattern of secretion, with peak secretion occurring during the breeding season (February-April, 136.95±33.8pg/ml). Progesterone concentrations in blow varied by reproductive status; pregnant females (410.6±87.8pg/ml) and females in the luteal phase of the estrous cycle (339.5±51.0pg/ml) had higher (p<0.0001) blow progesterone concentrations than non-pregnant females without a corpus luteum (242.5±27.3pg/ml). Results indicate that blow sample analysis can be used to detect variation in reproductive states associated with large differences in circulating testosterone or progesterone in belugas. Copyright © 2016 Elsevier Inc. All rights reserved.
Does human saliva decrease the antimicrobial activity of chlorhexidine against oral bacteria?
Abouassi, Thaer; Hannig, Christian; Mahncke, Katja; Karygianni, Lamprini; Wolkewitz, Martin; Hellwig, Elmar; Al-Ahmad, Ali
2014-10-10
Several studies have shown the antibacterial effectiveness of 0.2% chlorhexidine (CHX) in both in vitro and in vivo studies. In this way, CHX comes directly in contact with saliva. This in vitro study aimed at investigating the possible neutralizing effect of saliva on CHX. Saliva samples (12 ml) were collected from twenty healthy volunteers. The aerobic and anaerobic bacterial counts in saliva were determined on Colombia blood agar (CBA) and yeast cysteine agar (HCB), respectively. Saliva from each subject was divided among 4 experimental groups (3 ml/group). Samples were centrifuged at 4000 g for 10 min. The centrifuged salivary bacteria were incubated with the following solutions: 0.2% CHX in saliva, CHX in saliva with 7% ethanol, CHX in 0.9% NaCl, CHX in 0.9% NaCl with 7% ethanol. After exposure for 1 min or 3 min to these CHX solutions, the CHX was neutralized and the bacteria were cultivated, after which the number of colony forming units (aerobic and anaerobic) was determined. CHX reduced the CFU in all groups significantly (p = 0.0001). Therefore, CHX had a similar effect on both aerobic and anaerobic microorganisms. Significantly more bacteria survived the effect of CHX when kept in salivary solution. This effect from saliva could be compensated by the addition of ethanol. In the absence of saliva there was no significant difference observed in the effectiveness of CHX with respect to ethanol. Prolonging the exposure time to 3 min enhanced the effectiveness of CHX. The effect of saliva on the antimicrobial activity of CHX was weak albeit statistically significant. However, addition of 7% ethanol compensates this effect. The impact of saliva on the reduction of the antimicrobial efficacy of mouthrinses such as CHX needs to be taken into consideration with regard to improving their antibacterial properties.
Radwanski, K; Thill, M; Min, K
2014-05-01
If transfusion of older stored red cells is found to negatively affect clinical outcome, one possible alternative to shortened outdate is the use of new additive solutions (AS) that ameliorate the storage lesion. Erythro-Sol (E-Sol), a previously developed next-generation AS, has been reformulated into E-Sol 5, which is compatible with current anticoagulants and AS volumes. The effect of E-Sol 5 on red cells during storage compared to current AS has not been reported. Paired, ABO-matched whole-blood units were collected into CPD anticoagulant, pooled, split and processed into plasma and red cell units with either 110 ml of Adsol or 105 ml of E-Sol 5 within 8 h of collection. In Study 1, paired units in E-Sol 5 and Adsol were sampled on Day 0 and every 7 days up to Day 42 (n = 10). In Study 2, paired units in E-Sol 5 and Adsol were sampled only on Day 0 and Day 42 (n = 10). In Study 1, 2,3 DPG levels were maintained until Day 28 in E-Sol 5 units and Day 14 in Adsol units. ATP levels were higher in E-Sol 5 units until Day 21, after which they were comparable between the two groups. In both studies, metabolic activity was greater in E-Sol 5 units with respect to glucose consumption and lactate production. Morphology scores were higher, and haemolysis and microparticles generated were lower in E-Sol 5 vs. Adsol units. Weekly mixing of units lowered haemolysis and microparticle levels and increased potassium content on Day 42 in both additive solutions. Regardless of whether units are mixed weekly or are stored non-mixed, E-Sol 5 slows the progression of the red cell storage lesion and improves the overall in vitro quality of RBC throughout storage. © 2013 International Society of Blood Transfusion.
Abu-Qare, A W; Abou-Donia, M B
2001-09-01
A simple and reliable method was developed for the quantification of depleted uranium, the anti nerve agent drug pyridostigmine bromide (PB;3-dimethylaminocarbonyloxy-N-methyl pyridinium bromide) and its metabolite N-methyl-3-hydroxypyridinium bromide in rat plasma and urine. The method involved using solid phase extraction and spectrophotometric determination of uranium, and high performance liquid chromatography (HPLC) with reversed phase C(18) column, and UV detection at 280 nm for PB and its metabolite. Uranium was derivatized using dibenzoylmethane (DBM) then the absorbance was measured at 405 nm. PB and its metabolite were separated using a gradient of 1--40% acetonitrile in 0.1% triflouroacetic acid water solution (pH 3.2) at a flow rate of 0.8 ml/min in a period of 14 min. Limits of detection were 2 ng/ml for uranium and 50 ng/ml for PB and its metabolite. Limits of quantitation were between 10 and 100 ng/ml for uranium and the other two analytes, respectively. Average percentage recovery of five spiked plasma samples were 83.7+/-8.6, 76.8+/-6.7, 79.1+/-7.1, and from urine 82.7+/-8.6, 79.3+/-9.5 and 78.0+/-6.2, for depleted uranium, PB and N-methyl-3-hydroxypyridinium bromide, respectively. The relationship between peak areas and concentration was linear for standards between 100 and 1000 ng/ml for all three analytes. This method was applied to analyze the above chemicals and metabolites following combined administration in rats.
Li, Yu-hong; Lou, Xian-feng; Bao, Fang-ping
2006-01-01
Objective: To investigate the dynamics of vascular volume and the plasma dilution of lactated Ringer’s solution in patients during the induction of general and epidural anesthesia. Methods: The hemodilution of i.v. infusion of 1000 ml of lactated Ringer’s solution over 60 min was studied in patients undergoing general (n=31) and epidural (n=22) anesthesia. Heart rate, arterial blood pressure and hemoglobin (Hb) concentration were measured every 5 min during the study. Surgery was not started until the study period had been completed. Results: General anesthesia caused the greater decrease of mean arterial blood pressure (MAP) (mean 15% versus 9%; P<0.01) and thereby followed by a more pronounced plasma dilution, blood volume expansion (VE) and blood volume expansion efficiency (VEE). A strong linear correlation between hemodilution and the reduction in MAP (r=−0.50; P<0.01) was found. At the end of infusion, patients undergoing general anesthesia retained 47% (SD 19%) of the infused fluid in the circulation, while epidural anesthesia retained 29% (SD 13%) (P<0.001). Correspondingly, a fewer urine output (mean 89 ml versus 156 ml; P<0.05) and extravascular expansion (454 ml versus 551 ml; P<0.05) were found during general anesthesia. Conclusion: We concluded that the induction of general anesthesia caused more hemodilution, volume expansion and volume expansion efficiency than epidural anesthesia, which was triggered only by the lower MAP. PMID:16909476
Gallo, F R; Pagliuca, G; Multari, G; Panzini, G; D'amore, E; Altieri, I
2015-01-01
Natural substances present in herbal preparations should be carefully used because they can give toxic or therapeutic effects despite of their amount or the way of administration. The safety of products of vegetable origin must be assessed before commercialisation by monitoring the active ingredients and their metabolites. This study was therefore designed to identify and quantify arbutin and its metabolite hydroquinone, naturally present in Arctostaphylos uva-ursi (L.) Spreng plant in rat plasma, after an acute and subacute administration of aqueous arbutin solution in Wistar rats. For this purpose a reversed-phase high-performance liquid chromatography coupled with photodiode array detection was developed to assess the pharmacokinetic of arbutin and hydroquinone in plasma of female rats treated with aqueous arbutin solutions. The detection (arbutin: 0.0617 µg/ml and hydroquinone 0.0120 µg/ml) and quantification (arbutin: 0.2060 µg/ml and hydroquinone: 0.0400 µg/ml) limits were determined. At the arbutin concentration level of 10.7 µg/ml repeatability was 13.33% and its recovery 93.4±6.93%, while at the hydroquinone concentration level of 10.6 µg/ml repeatability was 11.66% and its recovery 92.9±7.75%. Furthermore the method was fully validated and the obtained data indicate that the new method provides good performances.
Gauhar, Shahnaz; Ali, Syed Ayub; Naqvi, Syed Baqir; Shoaib, Muhammad Harris
2014-03-01
In the present study, the pharmacokinetic and drug interaction evaluation of two drugs pefloxacin and paracetamol was carried out by a single-dose, two-treatment and two-sequence crossover design. Total fifteen healthy volunteers participated out of which ten completed the study. All were male volunteers, aged 22.36 years (means), with a mean weight of 76.45±12.05 Kg. The washout period between treatments was 5 week. Initially the method utilized for quantitative analysis of the drug was developed which was further validated. The study involved plasma protein precipitation with ethyl acetate and detection was done at 275nm. The retention time for pefloxacin 18±1 min and paracetamol were approximately 6±1 min, respectively. The calibration curve for pefloxacin was linear in the concentration range of 0.125-12.0mg/ml with r(2)=0.9987 in plasma. Standard concentration solution was maintained on the same temperature as that of volunteer's samples to optimize the periods for the determination of drug concentration in the plasma samples. Blood samples were collected from volunteers at different time intervals. The pharmacokinetics and drug interaction studies were anticipated by plotting concentration versus time-profiles. The value of AUC0-∞ in control was 67.355±3.174μg.h/ml, in treatment 61.242±3.868μg.h/ml along with relative bioavailability =91.395±4.864. Under the control and treatment condition the mean maximum plasma concentrations were found to be 4.679±0.248 μg/ml and 4.6595±0.266 μg/ml respectively. The average T(max) for plasma concentrations was 1.819±0.1743hr and 1.605 ±0.1134hr respectively. The biological half-lives in the two phases of studies were found to be 7.953±0.33hr in control and 7.7257±0.355hr in treatment. No significant effect were observed on the bioavailability and pharmacokinetics of pefloxacin by the concomitant administration with paracetamol, however very minor effect were observed that might be related with inter-individual variation in human volunteers. This pharmacokinetic studies also indicated that the level of drug (Cmax) do not differ from previous studies in different races.