Sample records for mm cross section

  1. [Relationship between image quality and cross-sectional area of phantom in three-dimensional positron emission tomography scan].

    PubMed

    Osawa, Atsushi; Miwa, Kenta; Wagatsuma, Kei; Takiguchi, Tomohiro; Tamura, Shintaro; Akimoto, Kenta

    2012-01-01

    The image quality in (18)FDG PET/CT often degrades as the body size increases. The purpose of this study was to evaluate the relationship between image quality and the body size using original phantoms of variable cross-sectional areas in PET/CT. We produced five water phantoms with different cross-sectional areas. The long axis of phantom was 925 mm, and the cross-sectional area was from 324 to 1189 cm(2). These phantoms with the sphere (diameter 10 mm) were filled with (18)F-FDG solution. The radioactivity concentration of background in the phantom was 1.37, 2.73, 4.09 and 5.46 kBq/mL. The scanning duration was 30 min in list mode acquisition for each measurement. Background variability (N(10 mm)), noise equivalent count rates (NECR(phantom)), hot sphere contrast (Q(H,10 mm)) as physical evaluation and visual score of sphere detection were measured, respectively. The relationship between image quality and the various cross-sectional areas was also analyzed under the above-mentioned conditions. As cross-sectional area increased, NECR(phantom) progressively decreased. Furthermore, as cross-sectional area increased, N(10 mm) increased and Q(H,10 mm) decreased. Image quality became degraded as body weight increased because noise and contrast contributed to image quality. The visual score of sphere detection deteriorated in high background radioactivity concentration because a false positive detection in cross-sectional area of the phantom increased. However, additional increases in scanning periods could improve the visual score. We assessed tendencies in the relationship between image quality and body size in PET/CT. Our results showed that time adjustment was more effective than dose adjustment for stable image quality of heavier patients in terms of the large cross-sectional area.

  2. Morphology of Mesiobuccal Root Canals of Maxillary First Molars: a comparison of CBCT scanning and Cross-sectioning.

    PubMed

    Lyra, Carina Maria; Delai, Débora; Pereira, Keila Cristina Rausch; Pereira, Guy Martins; Pasternak Júnior, Bráulio; Oliveira, César Augusto Pereira

    2015-10-01

    The aim of this study was to evaluate the mesiobuccal root of maxillary first molars, according to the root canal configuration, prevalence and location of isthmuses at 3 and 6 mm from the apex, comparing cone-beam computed tomography (CBCT) analysis and cross sectioning of roots by thirds. Images of the mesiobuccal root of 100 maxillary first molars were acquired by CBCT and then roots were cross-sectioned into two parts, starting at 3 mm from the apex. Data were recorded and analyzed according to Weine's classification for root canal configuration, and Hsu and Kim's classification for isthmuses. In the analysis of CBCT images, 8 root canals were classified as type I, 57 as type II, 35 as type III. In the cross-sectioning technique, 19 root canals were classified as type I, 60 as type II, 20 as type III and 1 as type IV. The classification of isthmuses was predominantly type I in both CBCT and cross-sectioning evaluations for sections at 3 mm from the apex, while for sections at 6 mm from the apex, the classification of isthmuses was predominantly types V and II in CBCT and cross-sectioning evaluations, respectively. The cross-sectioning technique showed better results in detection of the internal morphology of root canals than CBCT scanning.

  3. Macrosegregation in Al-7Si alloy caused by abrupt cross-section change during directional solidification

    NASA Astrophysics Data System (ADS)

    Ghods, M.; Johnson, L.; Lauer, M.; Grugel, R. N.; Tewari, S. N.; Poirier, D. R.

    2016-09-01

    Hypoeutectic Al-7 wt .% Si alloys were directionally solidified vertically downward in cylindrical molds that incorporated an abrupt cross-section decrease (9.5 mm to 3.2 mm diameter) which, after 5 cm, reverted back to 9.5 mm diameter in a Bridgman furnace; two constant growth speeds and thermal gradients were investigated. Thermosolutal convection and cross-section-change-induced shrinkage flow effects on macrosegregation were investigated. Dendrite clustering and extensive radial macrosegregation was seen, particularly in the larger cross-sections, before contraction and after expansion, this more evident at the lower growth speed. This alloy shows positive longitudinal macrosegregation near cross-section decrease followed by negative macrosegregation right after it; the extent of macrosegregation, however, decreases with increasing growth speed. Primary dendrite steepling intensified as solidification proceeded into the narrower section and negative longitudinal macrosegregation was seen on the re-entrant shelves at expansion. A two-dimensional model accounting for both shrinkage and thermo-solutal convection was used to simulate solidification and the resulting mushy-zone steepling and macrosegregation. The experimentally observed longitudinal and radial macrosegregation associated with the cross-section changes during directional solidification of an Al-7Si alloy is well captured by the numerical simulations.

  4. [Effect of resin infiltration on microhardness of artificial caries lesions].

    PubMed

    Liu, Yonghong; Deng, Hui; Tang, Longmei; Zhang, Zhiyong

    2015-12-01

    To compare the changes of enamel surface and cross-sectional microhardness of artificial caries immediately and after the twice demineralization through coating resin infiltration, fluoride varnish and fissure sealant. A total of forty bovine lower incisors enamel samples with artificial caries lesions by the demineralization liquid were used in the experiment. The specimens were then randomly divided into four groups as group A(resin infiltration), B(fluoride varnish), C (fissure sealant), D(control), 10 specimens in each group. The samples were sectioned vertically into two halves through the centre. One half of each sample the surface and cross-sectional microhardness was measured. The other half was put into demineralization liquid for 14 days, then the surface and cross-sectional microhardness was measured again. The cross section morphology of the samples was observed by scanning electron microscope. The surface of enamel had the highest microhardness value, and with the increase of cross- sectional depth, the microhardness value declined gradually. Variance analysis showed that the difference was statistically significant in the cross-section of different depth among the four groups(P<0.05). The microhardness values of the surface and the cross- section at 40 µm of each group in immediate measure showed the values were significantly higher in group A, B and C than in group D. There was no significant difference in the microhardness value of cross-section at 80 µm between group A[(324 ± 17) kg/mm(2)] and group C[(316 ± 20) kg/mm(2)], but they were significantly higher than group D. There was no significant difference between group B[(303 ± 13) kg/mm(2)] and group D[(294 ± 23) kg/mm(2)]. At 120 µm level, the microhardness value of group A was significantly higher than those of the other three groups. After the twice demineralization, the enamel surface microhardness value of the specimens was the same as the first measurement. In the cross-section at 40 µm level, the microhardness value was equal to the value of cross-section at 80 µm level of the first measurement. In the cross- section at 80 µm and 120 µm level, the microhardness value of group A was significantly higher than those of the other three groups. Resin infiltration can effectively strengthen microhardness of enamel surface and cross-section of different depth of artificial caries.

  5. High resolution ultrasonography of the tibial nerve in diabetic peripheral neuropathy.

    PubMed

    Singh, Kunwarpal; Gupta, Kamlesh; Kaur, Sukhdeep

    2017-12-01

    High-resolution ultrasonography of the tibial nerve is a fast and non invasive tool for diagnosis of diabetic peripheral neuropathy. Our study was aimed at finding out the correlation of the cross sectional area and maximum thickness of nerve fascicles of the tibial nerve with the presence and severity of diabetic peripheral neuropathy. 75 patients with type 2 diabetes mellitus clinically diagnosed with diabetic peripheral neuropathy were analysed, and the severity of neuropathy was determined using the Toronto Clinical Neuropathy Score. 58 diabetic patients with no clinical suspicion of diabetic peripheral neuropathy and 75 healthy non-diabetic subjects were taken as controls. The cross sectional area and maximum thickness of nerve fascicles of the tibial nerves were calculated 3 cm cranial to the medial malleolus in both lower limbs. The mean cross sectional area (22.63 +/- 2.66 mm 2 ) and maximum thickness of nerve fascicles (0.70 mm) of the tibial nerves in patients with diabetic peripheral neuropathy compared with both control groups was significantly larger, and statistically significant correlation was found with the Toronto Clinical Neuropathy Score ( p < 0.001). The diabetic patients with no signs of peripheral neuropathy had a larger mean cross sectional area (14.40 +/- 1.72 mm 2 ) and maximum thickness of nerve fascicles of the tibial nerve (0.40 mm) than healthy non-diabetic subjects (12.42 +/- 1.01 mm 2 and 0.30 mm respectively). The cross sectional area and maximum thickness of nerve fascicles of the tibial nerve is larger in diabetic patients with or without peripheral neuropathy than in healthy control subjects, and ultrasonography can be used as a good screening tool in these patients.

  6. Preparation of the apical part of the root canal by the Lightspeed and step-back techniques.

    PubMed

    Portenier, I; Lutz, F; Barbakow, F

    1998-03-01

    This study measured in vitro the displacement of natural canal centres in 18 human teeth before and after shaping by the step-back or Lightspeed techniques. Experimental roots (n = 9 per group), embedded in clear plastic, were cross-sectioned using a 0.1-mm-thick band saw at distances 1.25 mm, 3.25 mm and 5.25 mm from the apices. A stereo microscope was used to take 35 mm slides of the cut surfaces of the sectioned roots and canals. The slides of the uninstrumented canals were scanned into a computer and saved. Each sectioned root was then reassembled and the canals shaped by the step-back or Lightspeed technique. File size 40 and instrument size 50 were selected as the master apical file and master apical rotary for the step-back and Lightspeed groups, respectively. The 18 prepared canals were photographed, and the 35 mm slides scanned and computer stored as previously. This allowed the positions of the pre- and postinstrumented roots to be electronically superimposed for subsequent analyses. Displacements of the root canal centres before and after preparation were assessed in relation to the cross-sectional diameter of the files or instruments used. In addition, increases in cross-sectional area of the root canals after preparation were evaluated in relation to the cross-sectional area of the files or instruments used. Engine-driven nickel-titanium Lightspeed instruments caused significantly less (P < 0.001) displacement of the canal centres, so roots in the Lightspeed group remained better centred than those in the step-back group. The mean cross-sectional area after preparation in the Lightspeed group was significantly less (P < 0.001) than that recorded in the step-back group. Clinically, this implies less apical transportation and less dentine destruction with the Lightspeed technique than with the step-back technique.

  7. Study of the Bistatic Radar Cross Section of a 155-mm Artillery Round

    DTIC Science & Technology

    2017-06-01

    study . Section 3 compares the accuracy of the 2 EM modeling software packages used in this work. In Section 4, we discuss the relevant Approved for...ARL-TR-8045 ● JUNE 2017 US Army Research Laboratory Study of the Bistatic Radar Cross Section of a 155-mm Artillery Round by...when it is no longer needed. Do not return it to the originator. ARL-TR-8045 ● JUNE 2017 US Army Research Laboratory Study of the

  8. Evaluation of Single File Systems Reciproc, Oneshape, and WaveOne using Cone Beam Computed Tomography -An In Vitro Study.

    PubMed

    Dhingra, Annil; Ruhal, Nidhi; Miglani, Anjali

    2015-04-01

    Successful endodontic therapy depends on many factor, one of the most important step in any root canal treatment is root canal preparation. In addition, respecting the original shape of the canal is of the same importance; otherwise, canal aberrations such as transportation will be created. The purpose of this study is to compare and evaluate Reciprocating WaveOne ,Reciproc and Rotary Oneshape Single File Instrumentation System On Cervical Dentin Thickness, Cross Sectional Area and Canal Transportation on First Mandibular Molar Using Cone Beam Computed Tomography. Sixty Mandibular First Molars extracted due to periodontal reason was collected from the Department of Oral and Maxillofacial. Teeth were prepared using one rotary and two reciprocating single file system. Teeth were divided into 3 groups 20 teeth in each group. Pre instrumentation and Post instrumentation scans was done and evaluated for three parameters Canal Transportation, Cervical Dentinal Thickness, Cross-sectional Area. Results were analysed statistically using ANOVA, Post-Hoc Tukey analysis. The change in cross-sectional area after filing showed significant difference at 0mm, 1mm, 2mm and 7mm (p<0.001, p =0.006, 0.004 & <0.001 respectively). There was significant difference between wave one and oneshape; oneshape and reciproc at 0mm, 1mm, 2mm & 7mm (p-values for waveone and Oneshape <0.001, 0.022, 0.011 & <0.001 resp. and for oneshape and reciproc < 0.001, p= 0.011, p=0.008 & <0.001). On assessing the transportation of the three file system over a distance of 7 mm (starting from 0mm and then evaluation at 1mm, 2mm, 3mm, 5mm and 7mm), the results showed a significant difference among the file systems at various lengths (p= 0.014, 0.046, 0.004, 0.028, 0.005 & 0.029 respectively). Mean value of cervical dentinal removal is maximum at all the levels for oneshape and minimum for waveone showing the better quality of waveone and reciproc over oneshape file system. Significant difference was found at 9mm, 11mm and 12mm between all the three file systems (p<0.001,< 0.001, <0.001). It was concluded that reciprocating motion is better than rotary motion in all the three parameters Canal Transportation, Cross-sectional Area, Cervical Dentinal Thickness.

  9. M sub shell X-ray emission cross section measurements for Pt, Au, Hg, Pb, Th and U at 8 and 10 keV synchrotron photons

    NASA Astrophysics Data System (ADS)

    Kaur, Gurpreet; Gupta, Sheenu; Tiwari, M. K.; Mittal, Raj

    2014-02-01

    M sub shell X-ray emission cross sections of Pt, Au, Hg, Pb, Th and U at 8 and 10 keV photon energies have been determined with linearly polarized photon beam from Indus-2 synchrotron source. The measured cross sections have been reported for the first time and were used to check the available theoretical Dirac-Hartree-Slater (DHS) and Dirac-Fock (DF) values reported in literature and also the presently derived Non Relativistic Hartree-Slater (NRHS), DF and DHS values for Mξ, Mδ, Mα, Mβ, Mγ, Mm1 and Mm2 group of X-rays.

  10. Evaluation of Single File Systems Reciproc, Oneshape, and WaveOne using Cone Beam Computed Tomography –An In Vitro Study

    PubMed Central

    Dhingra, Annil; Miglani, Anjali

    2015-01-01

    Background Successful endodontic therapy depends on many factor, one of the most important step in any root canal treatment is root canal preparation. In addition, respecting the original shape of the canal is of the same importance; otherwise, canal aberrations such as transportation will be created. Aim The purpose of this study is to compare and evaluate Reciprocating WaveOne ,Reciproc and Rotary Oneshape Single File Instrumentation System On Cervical Dentin Thickness, Cross Sectional Area and Canal Transportation on First Mandibular Molar Using Cone Beam Computed Tomography. Materials and Methods Sixty Mandibular First Molars extracted due to periodontal reason was collected from the Department of Oral and Maxillofacial. Teeth were prepared using one rotary and two reciprocating single file system. Teeth were divided into 3 groups 20 teeth in each group. Pre instrumentation and Post instrumentation scans was done and evaluated for three parameters Canal Transportation, Cervical Dentinal Thickness, Cross-sectional Area. Results were analysed statistically using ANOVA, Post-Hoc Tukey analysis. Results The change in cross-sectional area after filing showed significant difference at 0mm, 1mm, 2mm and 7mm (p<0.001, p =0.006, 0.004 & <0.001 respectively). There was significant difference between wave one and oneshape; oneshape and reciproc at 0mm, 1mm, 2mm & 7mm (p-values for waveone and Oneshape <0.001, 0.022, 0.011 & <0.001 resp. and for oneshape and reciproc < 0.001, p= 0.011, p=0.008 & <0.001). On assessing the transportation of the three file system over a distance of 7 mm (starting from 0mm and then evaluation at 1mm, 2mm, 3mm, 5mm and 7mm), the results showed a significant difference among the file systems at various lengths (p= 0.014, 0.046, 0.004, 0.028, 0.005 & 0.029 respectively). Mean value of cervical dentinal removal is maximum at all the levels for oneshape and minimum for waveone showing the better quality of waveone and reciproc over oneshape file system. Significant difference was found at 9mm, 11mm and 12mm between all the three file systems (p<0.001,< 0.001, <0.001). Conclusion It was concluded that reciprocating motion is better than rotary motion in all the three parameters Canal Transportation, Cross-sectional Area, Cervical Dentinal Thickness. PMID:26023639

  11. The wire material and cross-section effect on double delta closing loops regarding load and spring rate magnitude: an in vitro study.

    PubMed

    Ferreira, M do A

    1999-03-01

    The mechanical behavior of orthodontics closing loops, with three different wire materials (stainless steel, cobalt-chromium and titanium-molybdenum) and with different cross-sections and a double delta design, was studied in tension tests. The springs were stress-relieved, except the titanium-molybdenum wires. There were 72 sample springs, divided into 33 stainless steel, 26 cobalt-chromium and 13 titanium-molybdenum, activated at 0.5 mm intervals, from neutral position to 3.0 mm. It was hypothesized that loads, after spring activation, and spring rate, are dependent on cross-section, wire material, and activation. The analysis of variance and the Tukey-Kramer test were applied to verify the differences between all coupled averages of the loads. Regression analysis was also used to verify if closing loops behavior was in accordance with Hooke's law and to obtain the spring rate. The results show that the loads are dependent on activation, cross-section, and wire material. Titanium-molybdenum 0.017 x 0.025 inch (Ormco) springs showed the smallest loads and the best spring rate. (beta = 84.9 g/mm)

  12. M sub-shell X-ray fluorescence cross-section measurements for six elements in the range Z = 78-92 at tuned synchrotron photon energies 5, 7 and 9 keV.

    NASA Astrophysics Data System (ADS)

    Bansal, Himani; Tiwari, M. K.; Mittal, Raj

    2018-01-01

    M sub-shell X-ray fluorescence cross-sections of elements Pt, Au, Hg, Pb, Th and U have been measured with linearly polarized photon beams from Indus-II synchrotron source at Raja Ramanna Centre for Advanced Technology (RRCAT), India at tuned 5, 7 and 9 keV energies less than the L3 edge energy of elements. Measurements at present energies and elements are not available in literature. Therefore, measured cross-sections for Mξ, Mδ, Mα, Mβ, Mγ, Mm1 and Mm2 group of X-rays were compared with calculated theoretical values based upon Non Relativistic Hartree-Slater (NRHS) and relativistic Dirac-Fork (DF) and Dirac-Hartree-Slater (DHS) models. The measured cross-sections along with our earlier quoted measurements at 8 and 10 keV by Kaur et al. [Nucl. Instrum. Meth. B, 2014; 320: 37] are found in good agreement with DF and DHS values around 20% deviations and are highly deviated from NRHS values. Most of the spots of observed high deviations in measured and theoretical cross-sections are found to coincide with the presence of crisscrosses/sharp variations in contributing physical parameters photo-ionization cross-sections σMi's and Coster-Kronig yields fij's with Zs.

  13. Hyponatremia and risk of seizures: a retrospective cross-sectional study.

    PubMed

    Halawa, Imad; Andersson, Tomas; Tomson, Torbjörn

    2011-02-01

    This retrospective cross-sectional study was carried out to study the association between different levels of hyponatremia and the occurrence of epileptic seizures in patients without a prior epilepsy diagnosis. We identified from the hospital database, 363 inpatients of a Swedish County hospital who between March 2003 and August 2006 were found to have serum sodium levels <125 mM. Medical records were reviewed and we identified 11 patients with seizures in conjunction with their hyponatremia. Seizures were the only neurologic manifestation of hyponatremia in patients with serum sodium levels >115 mM. Of 150 patients reviewed with serum sodium levels of 120-124 mM, one had a seizure. Using 120-124 mM as reference, odds ratios (95% confidence interval) for having seizures at serum sodium levels of 115-119 mM was 3.85 (0.40-37.53), 8.43 (0.859-82.85) at 110-114 mM, and 18.06 (1.96-166.86) at <110 mM. Wiley Periodicals, Inc. © 2011 International League Against Epilepsy.

  14. Posture and re-positioning considerations of a complete torso topographic analysis system for assessing scoliosis

    NASA Astrophysics Data System (ADS)

    Ajemba, Peter O.; Durdle, Nelson G.; Hill, Doug L.; Raso, V. J.

    2006-02-01

    The influence of posture and re-positioning (sway and breathing) on the accuracy of a torso imaging system for assessing scoliosis was evaluated. The system comprised of a rotating positioning platform and one or two laser digitizers. It required four partial-scans taken at 90 ° intervals over 10 seconds to generate two complete torso scans. Its accuracy was previously determined to be 1.1+/-0.9mm. Ten evenly spaced cross-sections obtained from forty scans of five volunteers in four postures (free-standing, holding side supports, holding front supports and with their hands on their shoulders) were used to assess the variability due to posture. Twenty cross-sections from twenty scans of two volunteers holding side supports were used to assess the variability due to positioning. The variability due to posture was less than 4mm at each cross-section for all volunteers. Variability due to sway ranged from 0-3.5mm while that due to breathing ranged from 0-3mm for both volunteers. Holding side supports was the best posture. Taking the four shots within 10 seconds was optimal. As major torso features that are indicative of scoliosis are larger than 4mm in size, the system could be used in obtaining complete torso images used in assessing and managing scoliosis.

  15. A prosthesis for banding the main pulmonary artery, capable of serial dilatation by balloon angioplasty.

    PubMed

    Vince, D J; Culham, J A

    1989-03-01

    A prosthesis constructed with a fatigued steel helix encased in a silicone rubber shield was used to band the main pulmonary artery in 10 dogs. After a mean duration of 138 days the banded site was dilated with a 20 mm diameter angioplasty catheter. This dilatation produced a mean increase of 44.3% in the cross-sectional area. A further mean increase of 2.2% in the cross-sectional area was measured 137 days after the dilatation. In five uncomplicated experiments a second dilatation was performed with a 23 mm diameter angioplasty catheter after a mean interval of 140 days. The second dilatation produced a further 21% increase in the cross-sectional area. In the five experiments in which two dilatations were performed, there was a total increase in the mean cross-sectional area of 94% produced 273 days after banding. This prosthesis maintains banding of the main pulmonary artery and can be serially dilated by balloon angioplasty.

  16. Transverse Chemotactic Migration of Bacteria from High to Low Permeability Regions in a Dual Permeability Porous Microfluidic Device

    NASA Astrophysics Data System (ADS)

    Singh, R.; Olson, M. S.

    2011-12-01

    Low permeability regions sandwiched between high permeability regions such as clay lenses are difficult to treat using conventional treatment methods. Trace concentrations of contaminants such as non-aqueous phase liquids (NAPLs) remain trapped in these regions and over the time diffuse out into surrounding water thereby acting as a long term source of groundwater contamination. Bacterial chemotaxis (directed migration toward a contaminant source), may be helpful in enhancing bioremediation of such contaminated sites. This study is focused on simulating a two-dimensional dual-permeability groundwater contamination scenario using microfluidic devices and evaluating transverse chemotactic migration of bacteria from high to low permeability regions. A novel bi-layer polydimethylsiloxane (PDMS) microfluidic device was fabricated using photolithography and soft lithography techniques to simulate contamination of a dual- permeability region due to leakage from an underground storage tank into a low permeability region. This device consists of a porous channel through which a bacterial suspension (Escherchia Coli HCB33) is flown and another channel for injecting contaminant/chemo-attractant (DL-aspertic acid) into the porous channel. The pore arrangement in the porous channel contains a 2-D low permeability region surrounded by high permeability regions on both sides. Experiments were performed under chemotactic and non-chemotactic (replacing attractant with buffer solution in the non porous channel) conditions. Images were captured in transverse pore throats at cross-sections 4.9, 9.8, and 19.6 mm downstream from the attractant injection point and bacteria were enumerated in the middle of each pore throat. Bacterial chemotaxis was quantified in terms of the change in relative bacterial counts in each pore throat at cross-sections 9.8 and 19.6 mm with respect to counts at the cross-section at 4.9 mm. Under non-chemotactic conditions, relative bacterial count was observed to decrease at 9.8 mm and 19.6 mm cross-sections in low permeability regions due to dilution with the injectate from the non-porous channel (Figure 1). However, relative bacterial counts increased in the low permeability region at both downstream cross-sections under chemotactic conditions. A large increase in relative bacterial count in the pore throats just outside the low permeability region was also observed at both cross-sections (Figure 1). The bacterial chemotactic response was observed to decrease linearly with increasing Darcy velocity and at flow rate 0.220 mm/s the chemotactic effect was offset by the advective flow in the porous channel.

  17. The cross-sectional shape of the fourfold semitendinosus tendon is oval, not round.

    PubMed

    Oshima, Takeshi; Nakase, Junsuke; Numata, Hitoaki; Takata, Yasushi; Tsuchiya, Hiroyuki

    2016-12-01

    The looped side of the semitendinosus tendon (ST) graft (i.e., the side inserted into the femoral tunnel during anterior cruciate ligament reconstruction) appears to be oval rather than round. The purpose of this study was to investigate the cross section of the fourfold semitendinosus tendon graft and, more specifically, the differences in pressure exerted by a rounded rectangular tunnel versus a round femoral tunnel. Seven STs were harvested from cadaveric knees and a fourfold ST graft was made. Aluminum cubes with round or rectangular tunnels containing four-way pressure-sensitive conductive sensors (vertically and bilaterally) were used. The area of both cubes was the same. The graft was inserted into the tunnels 15 mm from the looped edge. After measuring pressure, the graft was fixed using ultraviolet-curing acrylic resin and was cut at 7.5 mm and 15 mm from the lapel edge. The area, axes for the best fitting ellipse of the cross-section, and ellipticity of the axes were measured. In the round tunnel, the mean contact pressure was 287.0 ± 136.7 gf at the bilateral sensor; there was no contact pressure detected by the vertical sensor. In the rounded rectangular tunnel, the mean contact pressure was 260.9 ± 186.4 gf at the bilateral sensor and 352.9 ± 49.5 gf at the vertical sensor. Ellipticity was 1.25 ± 0.13 at 7.5 mm, and 1.17 ± 0.07 at 15 mm from the lapel edge of the graft. The cross-sectional shape of the fourfold ST graft was not round, but oval. Moreover, the rounded rectangular tunnel was more fitted to the graft than the round tunnel.

  18. State of the art timing in TOF-PET detectors with LuAG, GAGG and L(Y)SO scintillators of various sizes coupled to FBK-SiPMs

    NASA Astrophysics Data System (ADS)

    Gundacker, S.; Acerbi, F.; Auffray, E.; Ferri, A.; Gola, A.; Nemallapudi, M. V.; Paternoster, G.; Piemonte, C.; Lecoq, P.

    2016-08-01

    Time of flight (TOF) in positron emission tomography (PET) has experienced a revival of interest after its first introduction in the eighties. This is due to a significant progress in solid state photodetectors (SiPMs) and newly developed scintillators (LSO and its derivatives). Latest developments at Fondazione Bruno Kessler (FBK) lead to the NUV-HD SiPM with a very high photon detection efficiency of around 55%. Despite the large area of 4×4 mm2 it achieves a good single photon time resolution (SPTR) of 180±5ps FWHM. Coincidence time resolution (CTR) measurements using LSO:Ce codoped with Ca scintillators yield best values of 73±2ps FWHM for 2×2×3 mm3 and 117±3ps for 2×2×20 mm3 crystal sizes. Increasing the crystal cross-section from 2×2 mm2 to 3×3 mm2 a non negligible CTR deterioration of approximately 7ps FWHM is observed. Measurements with LSO:Ce codoped Ca and LYSO:Ce scintillators with various cross-sections (1×1 mm2 - 4×4 mm2) and lengths (3mm - 30mm) will be a basis for discussing on how the crystal geometry affects timing in TOF-PET. Special attention is given to SiPM parameters, e.g. SPTR and optical crosstalk, and their measured dependency on the crystal cross-section. Additionally, CTR measurements with LuAG:Ce, LuAG:Pr and GGAG:Ce samples are presented and the results are interpreted in terms of their scintillation properties, e.g. rise time, decay time, light yield and emission spectra.

  19. CORRELATION BETWEEN MARKERS OF PERIPHERAL NERVE FUNCTION AND STRUCTURE IN TYPE 1 DIABETES.

    PubMed

    Borire, Adeniyi A; Issar, Tushar; Kwai, Natalie C; Visser, Leo H; Simon, Neil G; Poynten, Ann M; Kiernan, Matthew C; Krishnan, Arun V

    2018-06-01

    Clinical and experimental studies in patients with type 1 and type 2 diabetes have demonstrated changes in ion channel function and nerve structure. In this study, we investigated the relationship between axonal dysfunction and morphological change in diabetic polyneuropathy using neuromuscular ultrasound and nerve excitability techniques. We also explored possible differences in this relationship between type 1 and type 2 diabetes. Nerve ultrasound and corresponding motor excitability studies were undertaken in 110 diabetes patients (50 type 1;60 type 2) and 60 age-matched controls (30 for each group). Neuropathy severity was assessed using Total Neuropathy Score. Median and tibial nerve cross-sectional areas were measured at non-entrapment sites using high resolution linear probe. Median and tibial nerve cross-sectional areas were significantly higher in diabetes patients compared to controls: Type1 (Median=7.6±0.2mm 2 vs. 6.3±0.1mm 2 ; Tibial=14.5±0.7mm 2 vs. 10.8±0.3mm 2 ,p<0.05) and Type 2 (Median=9.1±0.3mm 2 vs. 7.2±0.1mm 2 ; Tibial=18.5±1.0mm 2 vs. 12.8±0.5mm 2 ,p<0.05). In the type 1 cohort, significant correlations were found between nerve cross-sectional area and excitability parameters including resting current-threshold slope (Median: r=0.523,p<0.0001; Tibial: r=-0.571,p=0.004) and depolarizing threshold electrotonus at 90-100ms (Median: 0.424,p<0.01; Tibial: r=0.435,p=0.030). In contrast, there was no relationship between excitability values and nerve cross-sectional area in the type 2 cohort. This study has identified correlation between markers of axonal membrane function and structural abnormalities in peripheral nerves of type 1 diabetes patients. The differential relationship in nerve function and structure between Type 1 and Type 2 diabetes provides clinical evidence that different pathophysiological mechanisms underlie the development of neuropathy in these patient groups. This article is protected by copyright. All rights reserved.

  20. Modified floating-zone growth of organic single crystals

    NASA Astrophysics Data System (ADS)

    Kou, S.; Chen, C. P.

    1994-04-01

    For organic materials floating-zone crystal growth is superior to other melt growth processes in two significant respects: (1) the absence of crucible-induced mechanical damage and (2) minimum heating-induced chemical degradation. Due to the rather low surface tension of organic melts, however, floating-zone crystal growth under normal gravity has not been possible so far but microgravity is ideal for such a purpose. With the help of a modified floating-zone technique, organic single crystals of small cross-sections were test grown first under normal gravity. These small crystals were round and rectangular single crystals of benzil and salol, up to about 7 cm long and 6 mm in diameter or 9 mm × 3 mm in cross-section.

  1. Accurate electron gun-positioning mechanism for electron beam-mapping of large cross-section magnetic surfaces

    NASA Astrophysics Data System (ADS)

    Anderson, F. S. B.; Middleton, F.; Colchin, R. J.; Million, D.

    1989-04-01

    A method of accurately supporting and positioning an electron source inside a large cross-sectional area magnetic field which provides very low electron beam occlusion is reported. The application of electrical discharge machining to the fabrication of a 1-m truss support structure has provided an extremely long, rigid and mechanically strong electron gun support. Reproducible electron gun positioning to within 1 mm has been achieved at any location within a 1×0.6-m2 area. The extremely thin sections of the support truss (≤1.5 mm) have kept the electron beam occlusion to less than 3 mm. The support and drive mechanism have been designed and fabricated at the University of Wisconsin for application to the mapping of the magnetic surface structure of the Advanced Toroidal Facility torsatron1 at the Oak Ridge National Laboratory.

  2. Potential Bone to Implant Contact Area of Short Versus Standard Implants: An In Vitro Micro-Computed Tomography Analysis.

    PubMed

    Quaranta, Alessandro; DʼIsidoro, Orlando; Bambini, Fabrizio; Putignano, Angelo

    2016-02-01

    To compare the available potential bone-implant contact (PBIC) area of standard and short dental implants by micro-computed tomography (μCT) assessment. Three short implants with different diameters (4.5 × 6 mm, 4.1 × 7 mm, and 4.1 × 6 mm) and 2 standard implants (3.5 × 10 mm and 3.3 × 9 mm) with diverse design and surface features were scanned with μCT. Cross-sectional images were obtained. Image data were manually processed to find the plane that corresponds to the most coronal contact point between the crestal bone and implant. The available PBIC was calculated for each sample. Later on, the cross-sectional slices were processed by a 3-dimensional (3D) software, and 3D images of each sample were used for descriptive analysis and display the microtopography and macrotopography. The wide-diameter short implant (4.5 × 6 mm) showed the higher PBIC (210.89 mm) value followed by the standard (178.07 mm and 185.37 mm) and short implants (130.70 mm and 110.70 mm). Wide-diameter short implants show a surface area comparable with standard implants. Micro-CT analysis is a promising technique to evaluate surface area in dental implants with different macrodesign, microdesign, and surface features.

  3. Fluorescence-based surface magnifying chromoendoscopy and optical coherence tomography endoscope

    NASA Astrophysics Data System (ADS)

    Wall, R. Andrew; Barton, Jennifer K.

    2012-02-01

    A side-viewing, 2 mm diameter, surface magnifying chromoendoscopy (SMC)-optical coherence tomography (OCT) endoscope has been designed for simultaneous, non-destructive surface fluorescence visualization and cross-sectional imaging. We apply this endoscope to in vivo examination of mouse colon. A 30,000 element fiber bundle is combined with single mode fibers. The distal optics consist of a gradient-index lens and spacer to provide a magnification of 1 at a working distance of 1.58 mm in air, necessary to image the sample through a 0.23 mm thick outer glass envelope, and an aluminized right-angle prism fixed to the distal end of the GRIN lens assembly. The resulting 1:1 imaging system is capable of 3.9 μm lateral and 2.3 μm axial resolution in the OCT channel, and 125 lp/mm resolution across a 0.70 mm field of view in the SMC channel. The endoscope can perform high contrast crypt visualization, molecular imaging, and cross-sectional imaging of colon microstructure.

  4. Key Parameters Evaluation for Hip Prosthesis with Finite Element Analysis

    NASA Astrophysics Data System (ADS)

    Guo, Hongqiang; Li, Dichen; Lian, Qin; Li, Xiang; Jin, Zhongmin

    2007-09-01

    Stem length and cross section are two key parameters that influence the stability and longevity of metallic hip prosthesis in the total hip arthroplasty (THA). In order to assess their influence to the stress and fatigue behavior of hip prosthesis, a series model of hip prosthesis with round-shaped or drum-shaped cross section, and with different stem lengths were created. These models were analyzed under both static and dynamic loading conditions with finite element analysis, and dynamic loading represents normal walking was used in the dynamic analysis. The stress on the metallic stem, cement, and adjacent bone were got, micromotion on the cement-metal interface were got too. Safety factors for fatigue life of the hip prothesis were calculated based on data obtained from dynamic analysis. Static analysis shows that drum-shaped cross section can decrease the displacement of the stem, that stress on drum-shaped stem focus on the corner of the femoral neck and the distal part of hip prosthesis, whereas the stress on the round-shaped stem distributes evenly over most part of the stem, and maximum stress on stem prosthesis fluctuates with stem length bottoming out at stem length range from 80 mm to 110 mm, that drum-shaped stems with drum height 8 mm generate more stress at the distal part of stem than drum-shaped stems with drum height 10 mm and round stems do. Dynamic and fatigue analysis shows that drum-shaped stem with drum height 10 mm and stem length 90 mm has the greatest safety factor therefore long fatigue life.

  5. Iodine imaging in thyroid by fluorescent X-ray CT with 0.05 mm spatial resolution

    NASA Astrophysics Data System (ADS)

    Takeda, T.; Yu, Q.; Yashiro, T.; Zeniya, T.; Wu, J.; Hasegawa, Y.; Thet-Thet-Lwin; Hyodo, K.; Yuasa, T.; Dilmanian, F. A.; Akatsuka, T.; Itai, Y.

    2001-07-01

    Fluorescent X-ray computed tomography (FXCT) at a 0.05 mm in-plane spatial resolution and 0.05 mm slice thickness depicted the cross sectional distribution of endogenous iodine within thyroid. The distribution obtained from the FXCT image correlated closely to that obtained from the pathological pictures.

  6. Friedman tongue position and cone beam computed tomography in patients with obstructive sleep apnea.

    PubMed

    Harvey, Rebecca; O'Brien, Louise; Aronovich, Sharon; Shelgikar, Anita; Hoff, Paul; Palmisano, John; Stanley, Jeffrey

    2017-10-01

    Evaluate the correlation between Friedman Tongue Position (FTP) and airway cephalometrics in patients with obstructive sleep apnea (OSA). Retrospective review of adult patients with OSA undergoing Cone Beam Computed Tomography (CBCT). Collected data included age, sex, body mass index, apnea hypopnea index, FTP, and airway cephalometric parameters. Data analyses were performed using ANOVA, dichotomous t-testing, and linear regression. 203 patients were included in the analysis. (M:F 132:71). The mean posterior airway space (PAS) was inversely correlated ( p  = 0.001, r =.119) with higher FTP grades with means of 12.3 mm, 7.9 mm, 6.6 mm, and 4.3 mm, I-IV respectively. Minimal cross-sectional area for patients with FTP I-IV was 245.7, 179.8, 137.6, and 74.2 mm, 2 respectively ( p  = 0.002, r  = .095). Mean hyoid-mandibular plane (H-MP) for FTP I-IV was 20.6 mm, 20.4 mm, 24.7 mm, and 28.9 mm respectively. No statistically significant difference between H-MP values when comparing patients with FTP I or II ( p  = 0.22). There were statistically significant differences when these two groups were individually compared to FTP III and IV ( p  = 0.002). Linear regression analysis confirmed an independent association between FTP and PAS (β = -2.06, p  < 0.001), minimal cross-sectional area (β = -45.07, p  = 0.02), and H-MP (β = 3.03, p  = 0.01) controlling for BMI, age, AHI, and sex. Use of FTP is supported by objective CBCT cephalometric results, in particular the PAS, minimal cross-sectional area, and H-MP. Understanding the correlation between objective measurements of retroglossal collapse should allow Otolaryngologists to more confidently select patients who may require surgery to address the retroglossal area, particularly when the ability to perform cephalometric analysis is not possible. 4.

  7. Scattered light and accuracy of the cross-section measurements of weak absorptions: Gas and liquid phase UV absorption cross sections of CH3CFCl2

    NASA Technical Reports Server (NTRS)

    Fahr, A.; Braun, W.; Kurylo, M. J.

    1993-01-01

    Ultraviolet absorption cross sections of CH3CFCl2(HCFC-141b) were determined in the gas phase (190-260 nm) and liquid phase (230-260 mm) at 298 K. The liquid phase absorption cross sections were then converted into accurate gas phase values using a previously described procedure. It has been demonstrated that scattered light from the shorter-wavelength region (as little as several parts per thousand) can seriously compromise the absorption cross-section measurement, particularly at longer wavelengths where cross sections are low, and can be a source of discrepancies in the cross sections of weakly absorbing halocarbons reported in the literature. A modeling procedure was developed to assess the effect of scattered light on the measured absorption cross section in our experiments, thereby permitting appropriate corrections to be made on the experimental values. Modeled and experimental results were found to be in good agreement. Experimental results from this study were compared with other available determinations and provide accurate input for calculating the atmospheric lifetime of HCFC-141b.

  8. Low-energy proton induced M X-ray production cross sections for 70Yb, 81Tl and 82Pb

    NASA Astrophysics Data System (ADS)

    Shehla; Mandal, A.; Kumar, Ajay; Roy Chowdhury, M.; Puri, Sanjiv; Tribedi, L. C.

    2018-07-01

    The cross sections for production of Mk (k = Mξ, Mαβ, Mγ, Mm1) X-rays of 70Yb, 81Tl and 82Pb induced by 50-250 keV protons have been measured in the present work. The experimental cross sections have been compared with the earlier reported values and those calculated using the ionization cross sections based on the ECPSSR (Perturbed (P) stationary(S) state(S), incident ion energy (E) loss, Coulomb (C) deflection and relativistic (R) correction) model, the X-ray emission rates based on the Dirac-Fock model, the fluorescence and Coster-Kronig yields based on the Dirac-Hartree-Slater (DHS) model. In addition, the present measured proton induced X-ray production cross sections have also been compared with those calculated using the Dirac-Hartree-Slater (DHS) model based ionization cross sections and those based on the Plane wave Born Approximation (PWBA). The measured M X-ray production cross sections are, in general, found to be higher than the ECPSSR and DHS model based values and lower than the PWBA model based cross sections.

  9. Intralaryngeal thyroarytaenoid lateralisation using the Fast-Fix 360 system: a canine cadaveric study.

    PubMed

    Stegen, Ludo; Kitshoff, Adriaan M; Van Goethem, Bart; Vandekerckhove, Peter; de Rooster, Hilde

    2015-01-01

    Laryngeal paralysis is a condition in which failure of arytaenoid abduction results in a reduced rima glottidis cross-sectional area. The most commonly performed surgical techniques rely on unilateral abduction of the arytaenoid, requiring a lateral or ventral surgical approach to the larynx. The aim of the study was to investigate a novel minimally invasive intralaryngeal thyroarytaenoid lateralisation technique, using the Fast-Fix 360 meniscal repair system. Larynges were harvested from large breed canine cadavers. With the aid of Kirschner wires placed between the centre of the vocal process and the centre of an imaginary line between the cranial thyroid fissure and the cricothyroid articulation, the mean insertion angle was calculated. The Fast-Fix 360 delivery needle inserted intralaryngeally (n=10), according to a simplified insertion angle (70°), resulted in thyroid penetration (>2.5 mm from margin) in all patients. The Fast-Fix was applied unilaterally at 70° with the first toggle fired on the lateral aspect of the thyroid cartilage and inside the laryngeal cavity on retraction. The suture was tightened. Preprocedural (61.06±9.21 mm2) and postprocedural (138.37±26.12 mm2) rima glottidis cross-sectional area was significantly different (P<0.0001). The mean percentage increase in rima glottidis cross-sectional area was 125.96 per cent (±16.54 per cent). Intralaryngeal thyroarytaenoid laterlisation using the Fast-Fix 360 meniscal repair system ex vivo increased the rima glottidis cross-sectional area significantly.

  10. Micro-finite element analysis applied to high-resolution MRI reveals improved bone mechanical competence in the distal femur of female pre-professional dancers

    PubMed Central

    Rajapakse, C. S.; Diamond, M.; Honig, S.; Recht, M. P.; Weiss, D. S.; Regatte, R. R.

    2013-01-01

    Summary Micro-finite element analysis applied to high-resolution (0.234-mm length scale) MRI reveals greater whole and cancellous bone stiffness, but not greater cortical bone stiffness, in the distal femur of female dancers compared to controls. Greater whole bone stiffness appears to be mediated by cancellous, rather than cortical bone adaptation. Introduction The purpose of this study was to compare bone mechanical competence (stiffness) in the distal femur of female dancers compared to healthy, relatively inactive female controls. Methods This study had institutional review board approval. We recruited nine female modern dancers (25.7± 5.8 years, 1.63±0.06 m, 57.1±4.6 kg) and ten relatively inactive, healthy female controls matched for age, height, and weight (32.1±4.8 years, 1.6±0.04 m, 55.8±5.9 kg). We scanned the distal femur using a 7-T MRI scanner and a three-dimensional fast low-angle shot sequence (TR/TE= 31 ms/5.1 ms, 0.234 mm×0.234 mm×1 mm, 80 slices). We applied micro-finite element analysis to 10-mm-thick volumes of interest at the distal femoral diaphysis, metaphysis, and epiphysis to compute stiffness and cross-sectional area of whole, cortical, and cancellous bone, as well as cortical thickness. We applied two-tailed t-tests and ANCOVA to compare groups. Results Dancers demonstrated greater whole and cancellous bone stiffness and cross-sectional area at all locations (p< 0.05). Cortical bone stiffness, cross-sectional area, and thickness did not differ between groups (>0.08). At all locations, the percent of intact whole bone stiffness for cortical bone alone was lower in dancers (p<0.05). Adjustment for cancellous bone cross-sectional area eliminated significant differences in whole bone stiffness between groups (p>0.07), but adjustment for cortical bone cross-sectional area did not (p<0.03). Conclusions Modern dancers have greater whole and cancellous bone stiffness in the distal femur compared to controls. Elevated whole bone stiffness in dancers may be mediated via cancellous, rather than cortical bone adaptation. PMID:22893356

  11. Assessment of cross-sectional thickness and activity of masseter, anterior temporalis and orbicularis oris muscles in oral submucous fibrosis patients and healthy controls: an ultrasonography and electromyography study

    PubMed Central

    Bhowate, R R; Sharda, N

    2014-01-01

    Objectives: Oral submucous fibrosis (OSMF) is an insidious chronic disease that is associated with significant functional morbidity and an increased risk for malignancy. It initially affects the lamina propria of the oral mucosa, and, as the disease progresses, it involves the submucosa and deeper tissue, including muscles of the oral cavity, resulting in loss of fibroelasticity. OSMF is a pre-malignant condition mainly caused by areca nut chewing. The aim of this study was to find out the involvement of muscles of mastication and facial expression in patients with OSMF by assessing the cross-sectional thickness and activity of the masseter, anterior temporalis and orbicularis oris muscles by ultrasonography and electromyography and comparing with healthy controls and also to find out any correlation between the ultrasonographic cross-sectional thicknesses of the masseter, anterior temporalis and orbicularis oris muscles with electromyographic activity. Methods: 40 patients with OSMF were included in the study group, and the patients were divided into four groups on the basis of interincisal mouth opening, i.e. Group I (mouth opening >35 mm), Group II (mouth opening between 30 and 35 mm), Group III (mouth opening between 20 and 30 mm) and Group IV (mouth opening <20 mm). Ultrasonographic cross-sectional thickness and electromyographic activity (amplitude and duration) of the masseter, anterior temporalis and orbicualris oris muscles were recorded in patients with OSMF and 20 controls. Intergroup comparison of ultrasonographic cross-sectional thickness and activity (amplitude and duration) was done, and Pearson's correlation coefficient was applied to find out any relation between ultrasonographic and electromyographic findings. Results: Thickness and activity of the masseter muscle was significantly reduced in Group IV (mouth opening <20 mm) when compared with the control group. The anterior temporalis and orbicularis oris muscles remained unaffected. A positive correlation was observed between the thicknesses of the masseter muscle and the amplitude in Groups I, II and III; the anterior temporalis muscle in Group II and the control group; and the orbicularis oris muscle in Groups II, III and IV. Conclusions: It was concluded that, among the muscles studied, there was an early involvement of the masseter muscle in patients with OSMF compared with that of other muscles. PMID:24720604

  12. Assessment of cross-sectional thickness and activity of masseter, anterior temporalis and orbicularis oris muscles in oral submucous fibrosis patients and healthy controls: an ultrasonography and electromyography study.

    PubMed

    Kant, P; Bhowate, R R; Sharda, N

    2014-01-01

    Oral submucous fibrosis (OSMF) is an insidious chronic disease that is associated with significant functional morbidity and an increased risk for malignancy. It initially affects the lamina propria of the oral mucosa, and, as the disease progresses, it involves the submucosa and deeper tissue, including muscles of the oral cavity, resulting in loss of fibroelasticity. OSMF is a pre-malignant condition mainly caused by areca nut chewing. The aim of this study was to find out the involvement of muscles of mastication and facial expression in patients with OSMF by assessing the cross-sectional thickness and activity of the masseter, anterior temporalis and orbicularis oris muscles by ultrasonography and electromyography and comparing with healthy controls and also to find out any correlation between the ultrasonographic cross-sectional thicknesses of the masseter, anterior temporalis and orbicularis oris muscles with electromyographic activity. 40 patients with OSMF were included in the study group, and the patients were divided into four groups on the basis of interincisal mouth opening, i.e. Group I (mouth opening >35 mm), Group II (mouth opening between 30 and 35 mm), Group III (mouth opening between 20 and 30 mm) and Group IV (mouth opening <20 mm). Ultrasonographic cross-sectional thickness and electromyographic activity (amplitude and duration) of the masseter, anterior temporalis and orbicualris oris muscles were recorded in patients with OSMF and 20 controls. Intergroup comparison of ultrasonographic cross-sectional thickness and activity (amplitude and duration) was done, and Pearson's correlation coefficient was applied to find out any relation between ultrasonographic and electromyographic findings. Thickness and activity of the masseter muscle was significantly reduced in Group IV (mouth opening <20 mm) when compared with the control group. The anterior temporalis and orbicularis oris muscles remained unaffected. A positive correlation was observed between the thicknesses of the masseter muscle and the amplitude in Groups I, II and III; the anterior temporalis muscle in Group II and the control group; and the orbicularis oris muscle in Groups II, III and IV. It was concluded that, among the muscles studied, there was an early involvement of the masseter muscle in patients with OSMF compared with that of other muscles.

  13. Influence of cross-sectional geometry on the sensitivity and hysteresis of liquid-phase electronic pressure sensors

    NASA Astrophysics Data System (ADS)

    Park, Yong-Lae; Tepayotl-Ramirez, Daniel; Wood, Robert J.; Majidi, Carmel

    2012-11-01

    Cross-sectional geometry influences the pressure-controlled conductivity of liquid-phase metal channels embedded in an elastomer film. These soft microfluidic films may function as hyperelastic electric wiring or sensors that register the intensity of surface pressure. As pressure is applied to the elastomer, the cross-section of the embedded channel deforms, and the electrical resistance of the channel increases. In an effort to improve sensitivity and reduce sensor nonlinearity and hysteresis, we compare the electrical response of 0.25 mm2 channels with different cross-sectional geometries. We demonstrate that channels with a triangular or concave cross-section exhibit the least nonlinearity and hysteresis over pressures ranging from 0 to 70 kPa. These experimental results are in reasonable agreement with predictions made by theoretical calculations that we derive from elasticity and Ohm's Law.

  14. Fluorescence-based surface magnifying chromoendoscopy and optical coherence tomography endoscope

    NASA Astrophysics Data System (ADS)

    Wall, R. Andrew; Barton, Jennifer K.

    2012-08-01

    A side-viewing, 2.3-mm diameter, surface magnifying chromoendoscopy-optical coherence tomography (SMC-OCT) endoscope has been designed for simultaneous, nondestructive surface fluorescence visualization and cross-sectional imaging. We apply this endoscope to in vivo examination of the mouse colon. A 30,000 element fiber bundle is combined with single mode fibers, for SMC and OCT imaging, respectively. The distal optics consist of a gradient-index lens and spacer to provide a 1× magnification at a working distance of 1.58 mm in air, necessary to image the sample through a 0.23-mm thick outer glass envelope, and an aluminized right-angle prism fixed to the distal end of the gradient-index lens assembly. The resulting 1∶1 imaging system is capable of 3.9-μm lateral and 2.3-μm axial resolution in the OCT channel, and 125-lp/mm resolution across a 0.70-mm field of view in the SMC channel. The endoscope can perform high contrast crypt visualization, molecular imaging, and cross-sectional imaging of colon microstructure.

  15. Fluorescence-based surface magnifying chromoendoscopy and optical coherence tomography endoscope

    PubMed Central

    Wall, R. Andrew

    2012-01-01

    Abstract. A side-viewing, 2.3-mm diameter, surface magnifying chromoendoscopy-optical coherence tomography (SMC-OCT) endoscope has been designed for simultaneous, nondestructive surface fluorescence visualization and cross-sectional imaging. We apply this endoscope to in vivo examination of the mouse colon. A 30,000 element fiber bundle is combined with single mode fibers, for SMC and OCT imaging, respectively. The distal optics consist of a gradient-index lens and spacer to provide a 1× magnification at a working distance of 1.58 mm in air, necessary to image the sample through a 0.23-mm thick outer glass envelope, and an aluminized right-angle prism fixed to the distal end of the gradient-index lens assembly. The resulting 1∶1 imaging system is capable of 3.9-µm lateral and 2.3-µm axial resolution in the OCT channel, and 125-lp/mm resolution across a 0.70-mm field of view in the SMC channel. The endoscope can perform high contrast crypt visualization, molecular imaging, and cross-sectional imaging of colon microstructure. PMID:23224190

  16. SU-C-207-07: Quantification of Coronary Artery Cross-Sectional Area in CT Angiography Using Integrated Density: A Phantom Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, T; Ding, H; Torabzadeh, M

    2015-06-15

    Purpose: To investigate the feasibility of quantifying the cross-sectional area (CSA) of coronary arteries using integrated density in a physics-based model with a phantom study. Methods: In this technique the total integrated density of the object as compared with its local background is measured so it is possible to account for the partial volume effect. The proposed method was compared to manual segmentation using CT scans of a 10 cm diameter Lucite cylinder placed inside a chest phantom. Holes with cross-sectional areas from 1.4 to 12.3 mm{sup 2} were drilled into the Lucite and filled with iodine solution, producing amore » contrast-to-noise ratio of approximately 26. Lucite rods 1.6 mm in diameter were used to simulate plaques. The phantom was imaged with and without the Lucite rods placed in the holes to simulate diseased and normal arteries, respectively. Linear regression analysis was used, and the root-mean-square deviations (RMSD) and errors (RMSE) were computed to assess the precision and accuracy of the measurements. In the case of manual segmentation, two readers independently delineated the lumen in order to quantify the inter-reader variability. Results: The precision and accuracy for the normal vessels using the integrated density technique were 0.32 mm{sup 2} and 0.32 mm{sup 2}, respectively. The corresponding results for the manual segmentation were 0.51 mm{sup 2} and 0.56 mm{sup 2}. In the case of diseased vessels, the precision and accuracy of the integrated density technique were 0.46 mm{sup 2} and 0.55 mm{sup 2}, respectively. The corresponding results for the manual segmentation were 0.75 mm{sup 2} and 0.98 mm{sup 2}. The mean percent difference for the two readers was found to be 8.4%. Conclusion: The CSA based on integrated density had improved precision and accuracy as compared with manual segmentation in a Lucite phantom. The results indicate the potential for using integrated density to improve CSA measurements in CT angiography.« less

  17. Effect of Convection Associated with Cross-section Change during Directional Solidification of Binary Alloys on Dendritic Array Morphology and Macrosegregation

    NASA Astrophysics Data System (ADS)

    Ghods, Masoud

    This dissertation explores the role of different types of convection on macrosegregation and on dendritic array morphology of two aluminum alloys directionally solidified through cylindrical graphite molds having both cross-section decrease and increase. Al- 19 wt. % Cu and Al-7 wt. % Si alloys were directionally solidified at two growth speed of 10 and 29.1 mum s-1 and examined for longitudinal and radial macrosegregation, and for primary dendrite spacing and dendrite trunk diameter. Directional solidification of these alloys through constant cross-section showed clustering of primary dendrites and parabolic-shaped radial macrosegregation profile, indicative of "steepling convection" in the mushy-zone. The degree of radial macrosegregation increased with decreased growth speed. The Al- 19 wt. % Cu samples, grown under similar conditions as Al-7 wt. % Si, showed more radial macrosegregation because of more intense "stepling convection" caused by their one order of magnitude larger coefficient of solutal expansion. Positive macrosegregation right before, followed by negative macrosegregation right after an abrupt cross-section decrease (from 9.5 mm diameter to 3.2 mm diameter), were observed in both alloys; this is because of the combined effect of thermosolutal convection and area-change-driven shrinkage flow in the contraction region. The degree of macrosegregation was found to be higher in the Al- 19 wt. % Cu samples. Strong area-change-driven shrinkage flow changes the parabolic-shape radial macrosegregation in the larger diameter section before contraction to "S-shaped" profile. But in the smaller diameter section after the contraction very low degree of radial macrosegregation was found. The samples solidified through an abrupt cross-section increase (from 3.2 mm diameter to 9.5 mm diameter) showed negative macrosegregation right after the cross-section increase on the expansion platform. During the transition to steady-state after the expansion, radial macrosegregation profile in locations close to the expansion was found to be "S-shaped". This is attributed to the redistribution of solute-rich liquid ahead of the mushy-zone as it transitions from the narrow portion below into the large diameter portion above. Solutal remelting and fragmentation of dendrite branches, and floating of these fragmented pieces appear to be responsible for spurious grains formation in Al- 19 wt. % Cu samples after the cross-section expansion. New grain formation was not observed in Al-7 wt. % Si in similar locations; it is believed that this is due to the sinking of the fragmented dendrite branches in this alloy. Experimentally observed radial and axial macrosegregations agree well with the results obtained from the numerical simulations carried out by Dr. Mark Lauer and Prof. David R. Poirier at the University of Arizona. Trunk Diameter (TD) of dendritic array appears to respond more readily to the changing growth conditions as compared to the Nearest Neighbor Spacing (NNS) of primary dendrites.

  18. Microdroplet-etched highly birefringent low-loss fiber tapers.

    PubMed

    Mikkelsen, Jared C; Poon, Joyce K S

    2012-07-01

    We use hydrofluoric acid microdroplets to directly etch highly birefringent biconical fiber tapers from standard single-mode fibers. The fiber tapers have micrometer-sized cross sections, which are controlled by the etching condition. The characteristic teardrop cross section leads to a high group birefringence of B(G)≈0.017 and insertion losses <0.7 dB over waist lengths of about 2.1 mm.

  19. Intraoperative Assessment of Esophagogastric Junction Distensibility During Laparoscopic Heller Myotomy.

    PubMed

    DeHaan, Reece K; Frelich, Matthew J; Gould, Jon C

    2016-04-01

    We sought to characterize the changes in esophagogastric junction (EGJ) distensibility during Heller Myotomy with Dor fundoplication using the EndoFLIP device. Intraoperative distensibility measurements on 14 patients undergoing Heller myotomy with Dor fundoplication were conducted over an 18-month period. Minimum esophageal diameter, cross-sectional areas, and distensibility index were measured at 30 and 40 mL catheter volumes before myotomy, postmyotomy, and following Dor fundoplication. Distensibility index is defined as the narrowest cross-sectional area divided by the corresponding pressure expressed in mm/mm Hg. Heller myotomy was found to lead to significant changes in the distensibility characteristics of the EGJ. Minimum esophageal diameter and EGJ distensibility increased significantly with Heller myotomy.

  20. Intralaryngeal thyroarytaenoid lateralisation using the Fast-Fix 360 system: a canine cadaveric study

    PubMed Central

    Stegen, Ludo; Kitshoff, Adriaan M.; Van Goethem, Bart; Vandekerckhove, Peter; de Rooster, Hilde

    2015-01-01

    Introduction Laryngeal paralysis is a condition in which failure of arytaenoid abduction results in a reduced rima glottidis cross-sectional area. The most commonly performed surgical techniques rely on unilateral abduction of the arytaenoid, requiring a lateral or ventral surgical approach to the larynx. Aims and objectives The aim of the study was to investigate a novel minimally invasive intralaryngeal thyroarytaenoid lateralisation technique, using the Fast-Fix 360 meniscal repair system. Materials and methods Larynges were harvested from large breed canine cadavers. With the aid of Kirschner wires placed between the centre of the vocal process and the centre of an imaginary line between the cranial thyroid fissure and the cricothyroid articulation, the mean insertion angle was calculated. Results The Fast-Fix 360 delivery needle inserted intralaryngeally (n=10), according to a simplified insertion angle (70°), resulted in thyroid penetration (>2.5 mm from margin) in all patients. The Fast-Fix was applied unilaterally at 70° with the first toggle fired on the lateral aspect of the thyroid cartilage and inside the laryngeal cavity on retraction. The suture was tightened. Preprocedural (61.06±9.21 mm2) and postprocedural (138.37±26.12 mm2) rima glottidis cross-sectional area was significantly different (P<0.0001). The mean percentage increase in rima glottidis cross-sectional area was 125.96 per cent (±16.54 per cent). Conclusion Intralaryngeal thyroarytaenoid laterlisation using the Fast-Fix 360 meniscal repair system ex vivo increased the rima glottidis cross-sectional area significantly. PMID:26392907

  1. Effect of growth ring orientation and placement of earlywood and latewood on MOE and MOR of very-small clear Douglas-fir beams.

    Treesearch

    Amy T. Grotta; Robert J. Leichti; Barbara L. Gartner; G.R. Johnson

    2005-01-01

    ASTM standard sizes for bending tests (either 50 x 50 mm or 25 x 25 mm in cross-section) are not always suitable for research purposes that characterize smaller sections of wood. Moreover, the ASTM standards specify loading the sample on the longitudinal-tangential surface. If specimens are small enough, then the effects of both growth-ring orientation and whether...

  2. INDEX TO 35MM EDUCATIONAL FILMSTRIPS.

    ERIC Educational Resources Information Center

    University of Southern California, Los Angeles. School of Performing Arts.

    THE FIRST OF THE THREE PRINCIPAL SECTIONS OF THIS REFERENCE WORK IS A CROSS-REFERENCED SUBJECT MATTER SECTION SERVING AS A GUIDE TO SPECIFIC FILMSTRIPS THROUGH EITHER A GENERAL SUBJECT (E.G., BIOGRAPHY, FINE ARTS, SOCIOLOGY) OR A TERM OR TOPIC (E.G., CIVIL WAR, MITOSIS, TIDES). THE MIDDLE SECTION IS AN ALPHABETICAL TITLE-DESCRIPTIVE SECTION IN…

  3. Clinical acceptability of an ethylene-vinyl-acetate nonmedicated vaginal ring.

    PubMed

    Roumen, F J; Dieben, T O

    1999-01-01

    In an open study the acceptability of a newly designed vaginal ring was evaluated. The ring being developed for contraceptive purposes was made of ethylene-vinyl-acetate copolymer (EVA). In this study the ring did not contain active medication. Three groups of 20 healthy female volunteers were asked to use rings--with a diameter of 54 mm--for 21 consecutive days; each group was assigned rings with a different cross-sectional thickness of 3, 3.5, or 4 mm. Subjects were given diary cards to report on insertion and removal of the ring and on complaints. Of the 65 women who participated, 59 completed the study and used the ring for at least 21 days, giving an acceptability of 91% (59/65). No major differences were found between the three types of rings except for a sensation of expulsion, which was reported more often in the group assigned the smallest cross-sectional-thickness ring. Expulsion was reported once during intercourse in the 3.5-mm group. Insertion and removal of the rings were judged to be easy by the overall majority of the women. The ring was felt by the partner during intercourse in 35%-50% of couples. Further development of an active combined contraceptive EVA ring with a cross-sectional thickness of 4 mm seems a reasonable option. In future studies with the active ring, allowance for temporary removal of the ring during intercourse, if preferred, may be suggested.

  4. SU-E-T-663: Radiation Properties of a Water-Equivalent Material Formulated Using the Stoichiometric Analysis Method in Heavy Charged Particle Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yohannes, I; Vasiliniuc, S; Hild, S

    2015-06-15

    Purpose: A material has been designed to be employed as water-equivalent in particle therapy using a previously established stoichiometric analysis method (SAM). After manufacturing, experimental verification of the material’s water-equivalent path length (WEPL) and analysis of its total inelastic nuclear interaction cross sections for proton beams were performed. Methods: Using the SAM, we optimized the material composed of three base materials, i.e., polyurethane, calcium carbonate and microspheres. From the elemental composition of the compound, electron density, linear attenuation coefficients, particle stopping powers and inelastic nuclear cross sections for protons using data from ICRU 63 were calculated. The calculations were thenmore » compared to Hounsfield units (HUs) measured with 350 mAs at 80, 100, 120 and 140 kV and the WEPLs measured with three different ions: proton (106.8 MeV/u), helium (107.93 MeV/u) and carbon (200.3 MeV/u). Results: The material’s measured HUs (0.7±3.0 to 2.6±6.2 HU) as well as its calculated relative electron density (1.0001) are in close agreement with water as reference. The WEPLs measured on a 20.00 mm thick target were 20.16±0.12, 20.29±0.12 and 20.38±0.12 mmH2O for proton, helium and carbon ions, respectively. Within measurement uncertainties, these values verified the calculated WEPLs of 20.28 mmH2O (proton), 20.28 mmH2O (helium) and 20.26 mmH2O (carbon). Moreover, the calculated proton inelastic cross sections of the material differed only by 0.89% (100 MeV/u) and 0.01% (200 MeV/u) when compared to water. Conclusion: The SAM is capable of optimizing material with defined properties, e.g., HU, electron density, WEPL and inelastic nuclear interaction cross section for particle therapy. Such material will have a wide range of applications amongst others absolute dosimetry. This work was supported by grant ZIM KF2137107AK4 from the German Federal Ministry for Economic Affairs and Energy.« less

  5. Production and cross-sectional characterization of aligned co-electrospun hollow microfibrous bulk assemblies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Feng-Lei; The School of Materials, The University of Manchester, Manchester M13 9PL; CRUK-EPSRC Cancer Imaging Centre in Cambridge and Manchester

    2015-11-15

    The development of co-electrospun (co-ES) hollow microfibrous assemblies of an appreciable thickness is critical for many practical applications, including filtration membranes and tissue-mimicking scaffolds. In this study, thick uniaxially aligned hollow microfibrous assemblies forming fiber bundles and strips were prepared by co-ES of polycaprolactone (PCL) and polyethylene oxide (PEO) as shell and core materials, respectively. Hollow microfiber bundles were deposited on a fixed rotating disc, which resulted in non-controllable cross-sectional shapes on a macroscopic scale. In comparison, fiber strips were produced with tuneable thickness and width by additionally employing an x–y translation stage in co-ES. Scanning electron microscopy (SEM) imagesmore » of cross-sections of fiber assemblies were analyzed to investigate the effects of production time (from 0.5 h to 12 h), core flow rate (from 0.8 mL/h to 2.0 mL/h) and/or translation speed (from 0.2 mm/s to 5 mm/s) on the pores and porosity. We observed significant changes in pore size and shape with core flow rate but the influence of production time varied; five strips produced under the same conditions had reasonably good size and porosity reproducibility; pore sizes didn't vary significantly from strip bottom to surface, although the porosity gradually decreased and then returned to the initial level. - Highlights: • Hollow microfibrous assemblies based on co-electrospinning are demonstrated. • The thickness and width of co-electrospun strips were controllable. • Cross-sections of fibres had non-normally distributed pore sizes and shapes. • Cross-sections were significantly influenced by production time and flow rate. • Co-electrospun strips had reasonably good reproducible cross-sections.« less

  6. New method for evaluation of bendability based on three-point-bending and the evolution of the cross-section moment

    NASA Astrophysics Data System (ADS)

    Troive, L.

    2017-09-01

    Friction-free 3-point bending has become a common test-method since the VDA 238-100 plate-bending test [1] was introduced. According to this test the criterion for failure is when the force suddenly drops. It was found by the author that the evolution of the cross-section moment is a more preferable measure regarding the real material response instead of the force. Beneficially, the cross-section moment gets more or less a constant maximum steady-state level when the cross-section becomes fully plastified. An expression for the moment M is presented that fulfils the criteria for energy of conservation at bending. Also an expression calculating the unit-free moment, M/Me, i.e. current moment to elastic-moment ratio, is demonstrated specifically proposed for detection of failures. The mathematical expressions are simple making it easy to transpose measured force F and stroke position S to the corresponding cross-section moment M. From that point of view it’s even possible to implement, e.g. into a conventional measurement system software, studying the cross-section moment in real-time during a test. It’s even possible to calculate other parameters such as flow-stress and shape of curvature at every stage. It has been tested on different thicknesses and grades within the range from 1.0 to 10 mm with very good results. In this paper the present model is applied on a 6.1 mm hot-rolled high strength steel from the same batch at three different conditions, i.e. directly quenched, quenched and tempered, and a third variant quench and tempered with levelling. It will be shown that very small differences in material-response can be predicted by this method.

  7. Hypoglycemia and risk of seizures: a retrospective cross-sectional study.

    PubMed

    Imad, Halawa; Johan, Zelano; Eva, Kumlien

    2015-02-01

    Few studies have been dedicated to assess neurological symptoms in relations to hypoglycemia. In this study we investigated the association between different levels of hypoglycemia and the occurrence of epileptic seizures in patients without a prior diagnosis of epilepsy. A retrospective cross-sectional study. We identified 388 individuals from a laboratory database in Swedish regional hospital who had been found to have a glucose value of ≤3.5 mM between January and December 2009. Medical records were reviewed. Hypoglycemia was defined at three different categories: 0-2 mM (40 patients), 2.1-3 mM (154 patients) and 3.1-3.5 mM (194 patients). 14 patients had disturbance of consciousness including 3 with seizures. The majority of cases had coma, a generalized tonic-clonic seizure was seen only when s-glucose dropped below 2.0 mM. Two cases with focal seizure were noted, one at s-glucose 2.0 mM, and one at s-glucose 3.3 mM. The absolute risks (95% confidence interval) for having major neurological symptoms at glucose levels of ≤2.0 mM were 0.25 (0.13-0.41), 0.02 (0-0.06) at 2.1-3.0 mM and 0.01 (0-0.03) at 3.1-3.5 mM. Coma is the most common neurological symptom related to hypoglycemia. Epileptic seizures are rare and not as common as previously assumed. Copyright © 2014 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  8. Algorithm for Surface of Translation Attached Radiators (A-STAR). Volume 1: Formulation of the analysis

    NASA Astrophysics Data System (ADS)

    Medgyesimitschang, L. N.; Putnam, J. M.

    1982-05-01

    A general analytical formulation, based on the method of moments (MM) is described for solving electromagnetic problems associated with off-surface (wire) and aperture radiators on finite-length cylinders of arbitrary cross section, denoted in this report as bodies of translation (BOT). This class of bodies can be used to model structures with noncircular cross sections such as wings, fins and aircraft fuselages.

  9. Undergraduate students introduction to manual and rotary root canal instrumentation.

    PubMed

    Leonardi, Denise Piotto; Haragushiku, Gisele Aihara; Tomazinho, Flavia Sens Fagundes; Furuse, Adilson Yoshio; Volpato, Lusiane; Baratto-Filho, Flares

    2012-01-01

    The aim of this study was to evaluate the performance of undergraduates in their first contact with manual and rotary root canal instrumentation. Forty-two students who had never worked on a root canal before instrumented 42 extracted lower-incisors. Participants were assigned to one of two groups: Rotary instrumentation or manual instrumentation. Pre- and post-operative computed tomography scans were obtained with a 3-dimensional dental imaging system. Starting and finishing times of preparation were recorded. The cross-sectional area of the root canal was analyzed with 2-mm-below-the-apex initial and final transverse images recorded through a digital imaging system and analyzed with software to measure the initial and final area of the root canal in mm(2). Data from the cross-sectional area of the root canal and time spent were subjected to the Mann-Whitney's U-test (p<0.05). The rotary instrumentation group showed smaller time for preparation (p=0.0204). No differences between rotary and manual instrumentation regarding the cross-sectional area of the root canal were observed (p=0.25). No accidents occurred. Undergraduate students showed good performance in their first contact with the manual and rotary instrumentation with regard to time spent and cross-sectional area of the root canal, with no operative accidents.

  10. Small vertebral cross-sectional area and tall intervertebral disc in adolescent idiopathic scoliosis.

    PubMed

    Ponrartana, Skorn; Fisher, Carissa L; Aggabao, Patricia C; Chavez, Thomas A; Broom, Alexander M; Wren, Tishya A L; Skaggs, David L; Gilsanz, Vicente

    2016-09-01

    When compared to boys, girls have smaller vertebral cross-sectional area, which conveys a greater spinal flexibility, and a higher prevalence of adolescent idiopathic scoliosis. To test the hypothesis that small vertebral cross-sectional area and tall intervertebral disc height are structural characteristics of patients with adolescent idiopathic scoliosis. Using multiplanar imaging techniques, measures of vertebral cross-sectional area, vertebral height and intervertebral disc height in the lumbar spine were obtained in 35 pairs of girls and 11 pairs of boys with and without adolescent idiopathic scoliosis of the thoracic spine matched for age, height and weight. Compared to adolescents without spinal deformity, girls and boys with adolescent idiopathic scoliosis had, on average, 9.8% (6.68 ± 0.81 vs. 7.40 ± 0.99 cm(2); P = 0.0007) and 13.9% (8.22 ± 0.84 vs. 9.55 ± 1.61 cm(2); P = 0.009) smaller vertebral cross-sectional dimensions, respectively. Additionally, patients with adolescent idiopathic scoliosis had significantly greater values for intervertebral disc heights (9.06 ± 0.85 vs. 7.31 ± 0.62 mm and 9.09 ± 0.87 vs. 7.61 ± 1.00 mm for girls and boys respectively; both P ≤ 0.011). Multiple regression analysis indicated that the presence of scoliosis was negatively associated with vertebral cross-sectional area and positively with intervertebral disc height, independent of sex, age and body mass index. We provide new evidence that girls and boys with adolescent idiopathic scoliosis have significantly smaller vertebral cross-sectional area and taller intervertebral disc heights - two major structural determinants that influence trunk flexibility. With appropriate validation, these findings may have implications for the identification of children at the highest risk for developing scoliosis.

  11. Numerical Computation of the Radar Cross Section of Rockets and Artillery Rounds

    DTIC Science & Technology

    2015-09-01

    radar frequency bands: L, S, C , and X. Three targets are selected for this study: a 155-mm artillery round, and a 107-mm rocket, with and without...Unclassified c . THIS PAGE Unclassified 19b. TELEPHONE NUMBER (Include area code) (301) 394-1482 Standard Form 298 (Rev. 8/98) Prescribed by ANSI Std...without stabilization fins, and c ) 107-mm rocket with stabilization fins

  12. MODELING TIME DISPERSION DUE TO OPTICAL PATH LENGTH DIFFERENCES IN SCINTILLATION DETECTORS*

    PubMed Central

    Moses, W.W.; Choong, W.-S.; Derenzo, S.E.

    2015-01-01

    We characterize the nature of the time dispersion in scintillation detectors caused by path length differences of the scintillation photons as they travel from their generation point to the photodetector. Using Monte Carlo simulation, we find that the initial portion of the distribution (which is the only portion that affects the timing resolution) can usually be modeled by an exponential decay. The peak amplitude and decay time depend both on the geometry of the crystal, the position within the crystal that the scintillation light originates from, and the surface finish. In a rectangular parallelpiped LSO crystal with 3 mm × 3 mm cross section and polished surfaces, the decay time ranges from 10 ps (for interactions 1 mm from the photodetector) up to 80 ps (for interactions 50 mm from the photodetector). Over that same range of distances, the peak amplitude ranges from 100% (defined as the peak amplitude for interactions 1 mm from the photodetector) down to 4% for interactions 50 mm from the photodetector. Higher values for the decay time are obtained for rough surfaces, but the exact value depends on the simulation details. Estimates for the decay time and peak amplitude can be made for different cross section sizes via simple scaling arguments. PMID:25729464

  13. Modeling Time Dispersion Due to Optical Path Length Differences in Scintillation Detectors

    DOE PAGES

    Moses, W. W.; Choong, W. -S.; Derenzo, S. E.

    2014-08-20

    In this paper, we characterize the nature of the time dispersion in scintillation detectors caused by path length differences of the scintillation photons as they travel from their generation point to the photodetector. Using Monte Carlo simulation, we find that the initial portion of the distribution (which is the only portion that affects the timing resolution) can usually be modeled by an exponential decay. The peak amplitude and decay time depend both on the geometry of the crystal, the position within the crystal that the scintillation light originates from, and the surface finish. In a rectangular parallelpiped LSO crystal withmore » 3 mm × 3 mm cross section and polished surfaces, the decay time ranges from 10 ps (for interactions 1 mm from the photodetector) up to 80 ps (for interactions 50 mm from the photodetector). Over that same range of distances, the peak amplitude ranges from 100% (defined as the peak amplitude for interactions 1 mm from the photodetector) down to 4% for interactions 50 mm from the photodetector. Higher values for the decay time are obtained for rough surfaces, but the exact value depends on the simulation details. Finally, estimates for the decay time and peak amplitude can be made for different cross section sizes via simple scaling arguments.« less

  14. Incremental change in cross sectional area in small endotracheal tubes: A call for more size options.

    PubMed

    Mortelliti, Caroline L; Mortelliti, Anthony J

    2016-08-01

    To elucidate the relatively large incremental percent change (IPC) in cross sectional area (CSA) in currently available small endotracheal tubes (ETTs), and to make recommendation for lesser incremental change in CSA in these smaller ETTs, in order to minimize iatrogenic airway injury. The CSAs of a commercially available line of ETTs were calculated, and the IPC of the CSA between consecutive size ETTs was calculated and graphed. The average IPC in CSA with large ETTs was applied to calculate identical IPC in the CSA for a theoretical, smaller ETT series, and the dimensions of a new theoretical series of proposed small ETTs were defined. The IPC of CSA in the larger (5.0-8.0 mm inner diameter (ID)) ETTs was 17.07%, and the IPC of CSA in the smaller ETTs (2.0-4.0 mm ID) is remarkably larger (38.08%). Applying the relatively smaller IPC of CSA from larger ETTs to a theoretical sequence of small ETTs, starting with the 2.5 mm ID ETT, suggests that intermediate sizes of small ETTs (ID 2.745 mm, 3.254 mm, and 3.859 mm) should exist. We recommend manufacturers produce additional small ETT size options at the intuitive intermediate sizes of 2.75 mm, 3.25 mm, and 3.75 mm ID in order to improve airway management for infants and small children. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Pyramidal lobe of the thyroid gland and the thyroglossal duct remnant: a study using human fetal sections.

    PubMed

    Takanashi, Yoshitaka; Honkura, Yohei; Rodriguez-Vazquez, Jose Francisco; Murakami, Gen; Kawase, Tetsuaki; Katori, Yukio

    2015-01-01

    To investigate developmental changes in the thyroglossal duct, we observed serial sagittal sections of eight embryos (crown-rump length (CRL) 6-12 mm; approximately 5-6 weeks of gestation) as well as serial horizontal or cross-sections of 70 embryos and fetuses (CRL 15-110 mm; 6-15 weeks). In the sagittal sections, the thyroglossal duct was identified as a small sheet or mass of relatively large cells with vacuolization anterior, superior or inferior to the fourth pharyngeal arch artery. However, we found no continuous duct-like structure that reached the thyroid gland. Thus, previous classical schemes might have overestimated the continuity of the duct. Among cross-sections of 70 specimens, we found the thyroglossal duct remnant in only two specimens (CRL 15 mm and 100 mm), in contrast to the pyramidal lobe, which was seen in one-third of the specimens. The duct remnant ran downward along the lateral edge of the hyoid body to reach the anterior aspect of the thyroid cartilage. However, the connection between the pyramidal lobe and the duct remnant was interrupted by the anterior cervical muscles. Therefore, it was unlikely that the thyroglossal duct remnant would more frequently be evident in fetuses than in adults. The highly tortuous course of the duct along the lingual aspect of the hyoid body, which has been reported previously, appeared to become established near term. Descent of the thyroid gland was not evident after the CRL 20 mm stage (6 weeks): the gland appeared to retain its position at the level of the third-sixth cervical vertebrae. Copyright © 2014 Elsevier GmbH. All rights reserved.

  16. Short-Term effects of neuromuscular electrical stimulation on muscle architecture of the tibialis anterior and gastrocnemius in children with cerebral palsy: preliminary results of a prospective controlled study.

    PubMed

    Karabay, İlkay; Öztürk, Gökhan Tuna; Malas, Fevziye Ünsal; Kara, Murat; Tiftik, Tülay; Ersöz, Murat; Özçakar, Levent

    2015-09-01

    The aim of this study was to explore the short-term effects of neuromuscular electrical stimulation application on tibialis anterior (stimulated muscle) and gastrocnemius (antagonist) muscles' size and architecture in children with cerebral palsy by using ultrasound. This prospective, controlled study included 28 children diagnosed with spastic diplegic cerebral palsy. Participants were treated either with neuromuscular electrical stimulation application and conventional physiotherapy (group A) or with conventional physiotherapy alone (group B). Outcome was evaluated by clinical (gross motor function, selective motor control, range of motion, spasticity) and ultrasonographic (cross-sectional area, pennation angle, fascicle length of tibialis anterior and gastrocnemius muscles) measurements before and after treatment in both groups. Cross-sectional area values of tibialis anterior (238.7 ± 61.5 vs. 282.0 ± 67.1 mm) and gastrocnemius (207.9 ± 48.0 vs. 229.5 ± 52.4 mm) (P < 0.001 and P = 0.008, respectively) muscles were increased after treatment in group A. Cross-sectional area values of tibialis anterior muscle were decreased (257.3 ± 64.7 vs. 239.7 ± 60.0 mm) after treatment in group B (P < 0.001), and the rest of the measurements were found not to have changed significantly in either group. These results have shown that cross-sectional area of both the agonist and antagonist muscles increased after 20 sessions of neuromuscular electrical stimulation treatment. Future studies with larger samples and longer follow-up are definitely awaited for better evaluation of neuromuscular electrical stimulation application on muscle architecture and its possible correlates in clinical/functional outcome.

  17. Determination of the effective sample thickness via radiative capture

    DOE PAGES

    Hurst, A. M.; Summers, N. C.; Szentmiklosi, L.; ...

    2015-09-14

    Our procedure for determining the effective thickness of non-uniform irregular-shaped samples via radiative capture is described. In this technique, partial γ-ray production cross sections of a compound nucleus produced in a neutron-capture reaction are measured using Prompt Gamma Activation Analysis and compared to their corresponding standardized absolute values. For the low-energy transitions, the measured cross sections are lower than their standard values due to significant photoelectric absorption of the γ rays within the bulk-sample volume itself. Using standard theoretical techniques, the amount of γ-ray self absorption and neutron self shielding can then be calculated by iteratively varying the sample thicknessmore » until the observed cross sections converge with the known standards. The overall attenuation provides a measure of the effective sample thickness illuminated by the neutron beam. This procedure is illustrated through radiative neutron capture using powdered oxide samples comprising enriched 186W and 182W from which their tungsten-equivalent effective thicknesses are deduced to be 0.077(3) mm and 0.042(8) mm, respectively.« less

  18. Computerized tomography-assisted calculation of sinus augmentation volume.

    PubMed

    Krennmair, Gerald; Krainhöfner, Martin; Maier, Harald; Weinländer, Michael; Piehslinger, Eva

    2006-01-01

    This study was intended to calculate the augmentation volume for a sinus lift procedure based on cross-sectional computerized tomography (CT) scans for 2 different augmentation heights. Based on area calculations of cross-sectional CT scans, the volume of additional bone needed was calculated for 44 sinus lift procedures. The amount of bone volume needed to raise the sinus floor to heights of both 12 and 17 mm was calculated. To achieve a sinus floor height of 12 mm, it was necessary to increase the height by a mean of 7.2+/-2.1 mm (range, 3.0 to 10.5 mm), depending on the residual ridge height; to achieve a height of 17 mm, a mean of 12.4+/-2.0 mm (range, 8.5 to 15.5 mm) was required (P < .01). The calculated augmentation volume for an augmentation height of 12 mm was 1.7+/-.9 cm3; for an augmentation height of 17 mm, the volume required was 3.6+/-1.5 cm3. Increasing the height of the sinus lift by 5 mm, ie, from 12 mm to 17 mm augmentation height, increased the augmentation volume by 100%. A significant correlation was found between augmentation height and the calculated sinus lift augmentation volume (r = 0. 78, P < .01). Detailed preoperative knowledge of sinus lift augmentation volume is helpful as a predictive value in deciding on a donor site for harvesting autogenous bone and on the ratio of bone to bone substitute to use. Calculation of the augmentation size can help determine the surgical approach and thus perioperative treatment and the costs of the surgery for both patients and clinicians.

  19. Influence of the width and cross-sectional shape of major connectors of maxillary dentures on the accuracy of speech production.

    PubMed

    Wada, Junichiro; Hideshima, Masayuki; Inukai, Shusuke; Matsuura, Hiroshi; Wakabayashi, Noriyuki

    2014-01-01

    To investigate the effects of the width and cross-sectional shape of the major connectors of maxillary dentures located in the middle area of the palate on the accuracy of phonetic output of consonants using an originally developed speech recognition system. Nine adults (4 males and 5 females, aged 24-26 years) with sound dentition were recruited. The following six sounds were considered: [∫i], [t∫i], [ɾi], [ni], [çi], and [ki]. The experimental connectors were fabricated to simulate bars (narrow, 8-mm width) and plates (wide, 20-mm width). Two types of cross-sectional shapes in the sagittal plane were specified: flat and plump edge. The appearance ratio of phonetic segment labels was calculated with the speech recognition system to indicate the accuracy of phonetic output. Statistical analysis was conducted using one-way ANOVA and Tukey's test. The mean appearance ratio of correct labels (MARC) significantly decreased for [ni] with the plump edge (narrow connector) and for [ki] with both the flat and plump edge (wide connectors). For [çi], the MARCs tended to be lower with flat plates. There were no significant differences for the other consonants. The width and cross-sectional shape of the connectors had limited effects on the articulation of consonants at the palate. © 2015 S. Karger AG, Basel.

  20. Design and application of a small size SAFT imaging system for concrete structure

    NASA Astrophysics Data System (ADS)

    Shao, Zhixue; Shi, Lihua; Shao, Zhe; Cai, Jian

    2011-07-01

    A method of ultrasonic imaging detection is presented for quick non-destructive testing (NDT) of concrete structures using synthesized aperture focusing technology (SAFT). A low cost ultrasonic sensor array consisting of 12 market available low frequency ultrasonic transducers is designed and manufactured. A channel compensation method is proposed to improve the consistency of different transducers. The controlling devices for array scan as well as the virtual instrument for SAFT imaging are designed. In the coarse scan mode with the scan step of 50 mm, the system can quickly give an image display of a cross section of 600 mm (L) × 300 mm (D) by one measurement. In the refined scan model, the system can reduce the scan step and give an image display of the same cross section by moving the sensor array several times. Experiments on staircase specimen, concrete slab with embedded target, and building floor with underground pipe line all verify the efficiency of the proposed method.

  1. Development of a high-energy distributed energy source electromagnetic railgun with improved energy conversion efficiency

    NASA Astrophysics Data System (ADS)

    Tower, M. M.; Haight, C. H.

    1984-03-01

    The development status of a single-pulse distributed-energy-source electromagnetic railgun (ER) based on the design of Tower (1982) is reviewed. The five-stage ER is 3.65 m long, with energy inputs every 30 cm starting at the breech and a 12.7-mm-square bore cross section, and is powered by a 660-kJ 6-kV modular capacitor bank. Lexan cubes weighing 2.5 grams have been accelerated to velocities up to 8.5 km/sec at 500 kA and conversion efficiency up to 20 percent. Design goal for a 20-mm-sq-cross-section ER is acceleration of a 60-g projectile to 3-4 km/sec at 35-percent efficiency. Drawings, photographs, and graphs of performance are provided.

  2. Design of transmission-type phase holograms for a compact radar-cross-section measurement range at 650 GHz.

    PubMed

    Noponen, Eero; Tamminen, Aleksi; Vaaja, Matti

    2007-07-10

    A design formalism is presented for transmission-type phase holograms for use in a submillimeter-wave compact radar-cross-section (RCS) measurement range. The design method is based on rigorous electromagnetic grating theory combined with conventional hologram synthesis. Hologram structures consisting of a curved groove pattern on a 320 mmx280 mm Teflon plate are designed to transform an incoming spherical wave at 650 GHz into an output wave generating a 100 mm diameter planar field region (quiet zone) at a distance of 1 m. The reconstructed quiet-zone field is evaluated by a numerical simulation method. The uniformity of the quiet-zone field is further improved by reoptimizing the goal field. Measurement results are given for a test hologram fabricated on Teflon.

  3. Differences between office and 24-hour blood pressure control in hypertensive patients with CKD: A 5,693-patient cross-sectional analysis from Spain.

    PubMed

    Gorostidi, Manuel; Sarafidis, Pantelis A; de la Sierra, Alejandro; Segura, Julian; de la Cruz, Juan J; Banegas, Jose R; Ruilope, Luis M

    2013-08-01

    Previous studies have examined control rates of office blood pressure (BP) in chronic kidney disease (CKD). However, recent evidence suggests major discrepancies between office and 24-hour BP values in hypertensive populations. This study examined concordance/discordance between office- and ambulatory-based BP control in a large cohort of patients with CKD. Cross-sectional. 5,693 hypertensive individuals with CKD stages 1-5 from the Spanish ABPM (ambulatory BP monitoring) Registry. Thresholds of 140/90 and 130/80 mm Hg for office BP and 24-hour ambulatory BP, respectively. Age, sex, body mass index, waist circumference, hypertension duration, kidney measures, diabetes, dyslipidemia, target-organ damage, and cardiovascular comorbid conditions. Misclassification of BP control as "white-coat" hypertension (office BP ≥140/90 mm Hg, 24-hour BP <130/80 mm Hg) or masked hypertension (office BP <140/90 mm Hg, 24-hour BP ≥130/80 mm Hg). Standardized office-based BP and 24-hour ABPM. Mean age was 61.0 ± 13.9 (SD) years and 52.6% were men. The proportion with white-coat hypertension was 28.8% (36.8% of patients with office BP ≥140/90 mm Hg) and that of masked hypertension was 7.0% (but 32.1% of patients with office BP <140/90 mm Hg). Female sex, aging, obesity, and target-organ damage were associated with white-coat hypertension; aging and obesity were associated with masked hypertension. Only 21.7% and 8.1% of the CKD population had office BP <140/90 and <130/80 mm Hg, respectively. In contrast, 43.5% of individuals had average 24-hour BP <130/80 mm Hg. Cross-sectional design, longitudinal associations cannot be established. Misclassification of BP control at the office was observed in 1 of 3 hypertensive patients with CKD. Ambulatory-based control rates were far better than office-based rates. Nevertheless, the burden of uncontrolled ambulatory BP and misclassification of BP control at the office constitutes a call for wider use of ABPM to evaluate the success of hypertension treatment in patients with CKD. Copyright © 2013 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  4. Macrosegregation Due to Convection in Al-19Cu Alloy Directionally Solidified Through an Abrupt Expansion in Cross-Section: A Comparison with Al-7Si

    NASA Astrophysics Data System (ADS)

    Ghods, M.; Lauer, M.; Grugel, R. N.; Tewari, S. N.; Poirier, D. R.

    2017-10-01

    Hypoeutectic Al-19 wt.% Cu alloys were directionally solidified at two different growth speeds in cylindrical molds that featured an abrupt increase in cross-section, from 3.2 to 9.5 mm in diameter. The effects of thermosolutal convection and shrinkage flow induced by the cross-section change on macrosegregation were investigated. Dendrite clustering and extensive radial macrosegregation were seen, particularly in the larger cross-section after expansion. Negative longitudinal macrosegregation right after the cross-section increase was observed; the extent of macrosegregation, however, decreases with increasing growth speed. Both thermal and flow effects due to cross-section change were seen to influence the radial macrosegregation immediately before, and after the expansion. Radial macrosegregation pattern was found to be changing as the mushy zone enters the larger cross-section region above the cross-section change where the solidification is in its unsteady state. The effect of the solutal expansion coefficient on macrosegregation was studied by comparing the degree of thermosolutal convection in Al-19 wt.% Cu with a previous study in which we investigated Al-7 wt.% Si. A two-dimensional model accounting for both shrinkage and thermosolutal convection was used to simulate the resulting steepling, as well as the axial and radial macrosegregation. The experimentally observed macrosegregation associated with the expansion during directional solidification is well predicted by the numerical simulations.

  5. Incidence of hypo- and hyper-capnia in a cross-sectional European cohort of ventilated newborn infants.

    PubMed

    van Kaam, Anton H; De Jaegere, Anne P; Rimensberger, Peter C

    2013-07-01

    To determine the incidence of hypo- and hyper-capnia in a European cohort of ventilated newborn infants. Two-point cross-sectional prospective study in 173 European neonatal intensive care units. Patient characteristics, ventilator settings and measurements, and blood gas analyses were collected for endotracheally ventilated newborn infants on two separate dates. A total of 1569 blood gas analyses were performed in 508 included patients with a mean±SD Pco2 of 48±12 mm Hg or 6.4±1.6 kPa (range 17-104 mm Hg or 2.3-13.9 kPa). Hypocapnia (Pco2<30 mm Hg or 4 kPa) and hypercapnia (Pco2>52 mm Hg or 7 kPa) was present in, respectively, 69 (4%) and 492 (31%) of the blood gases. Hypocapnia was most common in the first 3 days of life (7.3%) and hypercapnia after the first week of life (42.6%). Pco2 was significantly higher in preterm infants (49 mm Hg or 6.5 kPa) than term infants (43 mm Hg or 5.7 kPa) and significantly lower during pressure-limited ventilation (47 mm Hg or 6.3±1.6 kPa) compared with volume-targeted ventilation (51 mm Hg or 6.8±1.7 kPa) and high-frequency ventilation (50 mm Hg or 6.7±1.7 kPa). This study shows that hypocapnia is a relatively uncommon finding during neonatal ventilation. The higher incidence of hypercapnia may suggest that permissive hypercapnia has found its way into daily clinical practice.

  6. Safe Zone Quantification of the Third Sacral Segment in Normal and Dysmorphic Sacra.

    PubMed

    Hwang, John S; Reilly, Mark C; Shaath, Mohammad K; Changoor, Stuart; Eastman, Jonathan; Routt, Milton Lee Chip; Sirkin, Michael S; Adams, Mark R

    2018-04-01

    To quantify the osseous anatomy of the dysmorphic third sacral segment and assess its ability to accommodate internal fixation. Retrospective chart review of a trauma database. University Level 1 Trauma Center. Fifty-nine patients over the age of 18 with computed tomography scans of the pelvis separated into 2 groups: a group with normal pelvic anatomy and a group with sacral dysmorphism. The sacral osseous area was measured on computed tomography scans in the axial, coronal, and sagittal planes in normal and dysmorphic pelves. These measurements were used to determine the possibility of accommodating a transiliac transsacral screw in the third sacral segment. In the normal group, the S3 coronal transverse width averaged 7.71 mm and the S3 axial transverse width averaged 7.12 mm. The mean S3 cross-sectional area of the normal group was 55.8 mm. The dysmorphic group was found to have a mean S3 coronal transverse width of 9.49 mm, an average S3 axial transverse width of 9.14 mm, and an S3 cross-sectional area of 77.9 mm. The third sacral segment of dysmorphic sacra has a larger osseous pathway available to safely accommodate a transiliac transsacral screw when compared with normal sacra. The S3 segment of dysmorphic sacra can serve as an additional site for screw placement when treating unstable posterior pelvic ring fractures.

  7. Three Dimensional Mesoscale Analysis of Translamellar Cross-Bridge Morphologies in the Annulus Fibrosus using Optical Coherence Tomography

    PubMed Central

    Han, Sang Kuy; Chen, Chao-Wei; Wierwille, Jerry; Chen, Yu; Hsieh, Adam H.

    2014-01-01

    The defining characteristic of the annulus fibrosus (AF) of the intervertebral disc (IVD) has long been the lamellar structures that consist of highly ordered collagen fibers arranged in alternating oblique angles from one layer to the next. However, a series of recent histologic studies have demonstrated that AF lamellae contain elastin- and type VI collagen-rich secondary “cross-bridge” structures across lamellae. In this study, we use optical coherence tomography (OCT) to elucidate the three-dimensional (3D) morphologies of these translamellar cross-bridge in AF tissues. Mesoscale volumetric images by OCT reveal a highly heterogeneous spatial network and distribution of 3-D translamellar cross-bridges. The results of this study confirm the translamellar cross-bridge is identified as a distinguishable structure, which is laid in the interbundle space of adjacent lamellae and crisscrosses multiple lamellae in the radial direction. In contrast to previously proposed models extrapolated from 2-D sections, results from this current study show that translamellar cross-bridges exist as a complex, interconnected network. We also found much greater variation in lengths of cross-bridges within the interbundle space of lamellae (0.8-1.4 mm from the current study versus 0.3-0.6 mm from 2-D sections). OCT-based 3-D morphology of translamellar cross-bridge provides novel insight into the AF structure. PMID:25564974

  8. Method for procuring specific populations of viable human prostate cells for research.

    PubMed

    Fischer, A H; Philips, A; Taysavang, P; McKenney, J K; Amin, M B

    2001-04-01

    A wider range of research can be conducted on viable tissue samples than on fixed or frozen samples. A major obstacle to studying viable prostate tissue samples is the inability to accurately identify cancer on direct examination of unembedded tissue. We used a dissecting microscope to identify cancer in unfixed prostate tissue samples stained on the cut surface with 0.5% aqueous toluidine blue. We measured the diagnostic accuracy of this technique in 25 consecutive prostatectomies, determined the viability of procured samples, and estimated the effect on final pathologic assessment. Both surfaces of a 3- to 5-mm thick cross-section taken midway between base and apex of the prostate were examined. A 4-mm punch biopsy was directed to one benign and one malignant area when clearly present. The dissecting microscope allowed clearcut recognition of carcinoma in 17 of the 25 cross-sections, and carcinoma was confirmed in all 17 (100%). In 8 of 25 cases, no procurement was attempted because no carcinoma was evident in the one cross-section studied. Twenty of 25 cross-sections were adequate for benign tissue procurement; five of the cross-sections were not suitable for procurement because of the presence of extensive carcinoma or atrophy. Seventeen of the 20 were accurately diagnosed as benign (85%); one showed pseudohyperplastic adenocarcinoma, one showed focal high-grade prostatic intraepithelial neoplasia, and one showed urothelial carcinoma in situ. Prostatic epithelium obtained with the technique remains viable and can be separated from stroma. The dissecting microscope technique appears to facilitate rather than interfere with accurate pathologic assessment: extraprostatic extension or positive margins were correctly identified during tissue procurement in three cases. The procedure takes only about 30 minutes.

  9. Comparison of cleaning efficiency and deformation characteristics of Twisted File and ProTaper rotary instruments

    PubMed Central

    Li, Hang; Zhang, Chenzheng; Li, Qing; Wang, Changning; Song, Yaling

    2014-01-01

    Objective: The objective of the following study is to compare the cleaning efficiency and deformation characteristics of Twisted File (TF) and ProTaper (PT) nickel-titanium rotary instruments in root canal preparation. Materials and Methods: A total of 52 canals from 26 extracted maxillary first molars were randomly assigned into two groups of each including 13 mesiobuccal and 12 distobuccal (DB) canals. Two DB canals were as blank controls. After preparation with TF and PT, we recorded the preparation time and evaluate the amounts of debris and smear layer at apical, middle and coronal canals under scanning electron microscopy (SEM). Three cross-sections of canals at 3 mm, 5 mm and 7 mm from the apex foramens were scanned before and after preparation under micro-computed tomography. Changes of the cross-section area (CSA) at the three levels were calculated with Photoshop CS4. File deformation was also investigated under SEM. Two groups were statistically compared with Mann-Whitney test and independent sample t-test. Results: Less debris and smear layer were found in coronal regions of canals prepared with TF (P = 0.006, P = 0.001, respectively). TF group displayed more CSA change than PT group (P = 0.045) at cross-sections of 5 mm from the apex foramens and took significantly less preparation time than PT group did (P = 9.06 × 10−28). All five TF files without obvious micro-cracks and two out of 25 PT files with many micro-cracks showed visible unwound deformation. Conclusion: Neither TF nor PT achieves complete cleanliness of canal walls. Their deformation features might indicate different fracture resistance. TF single-file technique would substantially shorten the time of root canal preparation. PMID:24966769

  10. Reference Charts for Fetal Cerebellar Vermis Height: A Prospective Cross-Sectional Study of 10605 Fetuses

    PubMed Central

    Cignini, Pietro; Giorlandino, Maurizio; Brutti, Pierpaolo; Mangiafico, Lucia; Aloisi, Alessia; Giorlandino, Claudio

    2016-01-01

    Objective To establish reference charts for fetal cerebellar vermis height in an unselected population. Methods A prospective cross-sectional study between September 2009 and December 2014 was carried out at ALTAMEDICA Fetal–Maternal Medical Centre, Rome, Italy. Of 25203 fetal biometric measurements, 12167 (48%) measurements of the cerebellar vermis were available. After excluding 1562 (12.8%) measurements, a total of 10605 (87.2%) fetuses were considered and analyzed once only. Parametric and nonparametric quantile regression models were used for the statistical analysis. In order to evaluate the robustness of the proposed reference charts regarding various distributional assumptions on the ultrasound measurements at hand, we compared the gestational age-specific reference curves we produced through the statistical methods used. Normal mean height based on parametric and nonparametric methods were defined for each week of gestation and the regression equation expressing the height of the cerebellar vermis as a function of gestational age was calculated. Finally the correlation between dimension/gestation was measured. Results The mean height of the cerebellar vermis was 12.7mm (SD, 1.6mm; 95% confidence interval, 12.7–12.8mm). The regression equation expressing the height of the CV as a function of the gestational age was: height (mm) = -4.85+0.78 x gestational age. The correlation between dimension/gestation was expressed by the coefficient r = 0.87. Conclusion This is the first prospective cross-sectional study on fetal cerebellar vermis biometry with such a large sample size reported in literature. It is a detailed statistical survey and contains new centile-based reference charts for fetal height of cerebellar vermis measurements. PMID:26812238

  11. Features of two-phase flow in a microchannel of 0.05×20 mm

    NASA Astrophysics Data System (ADS)

    Ronshin, Fedor

    2017-10-01

    We have studied the two-phase flow in a microchannel with cross-section of 0.05×20 mm2. The following two-phase flow regimes have been registered: jet, bubble, stratified, annular, and churn ones. The main features of flow regimes in this channel such as formation of liquid droplets in all two-phase flows have been distinguished.

  12. Esophagogastric junction distensibility assessed using the functional lumen imaging probe

    PubMed Central

    Chen, Joan W; Rubenstein, Joel H

    2017-01-01

    AIM To assess reference values in the literature for esophageal distensibility and cross-sectional area in healthy and diseased subjects measured by the functional lumen imaging probe (FLIP). METHODS Systematic search and review of articles in Medline and Embase pertaining to the use of FLIP in the esophagus was conducted in accordance with the PRISMA guidelines. Cross-sectional area and distensibility at the esophagogastric junction (EGJ) were abstracted for normal subjects, achalasia, and gastroesophageal reflux disease (GERD) patients, stratified by balloon length and volume of inflation. RESULTS Six achalasia studies (n = 154), 3 GERD (n = 52), and 5 studies including healthy controls (n = 98) were included in the systematic review. Normative data varied widely amongst studies of healthy volunteers. In contrast, studies in achalasia patients uniformly demonstrated low point estimates in distensibility ≤ 1.6 mm2/mmHg prior to treatment that increased to ≥ 3.4 mm2/mmHg following treatment at 40mL bag volume. In GERD patients, distensibility fell to the range of untreated achalasia (≤ 2.85 mm2/mmHg) following fundoplication. CONCLUSION FLIP may be a useful tool in assessment of treatment efficacy in achalasia. The drastic drop in EGJ distensibility after fundoplication suggests that FLIP measurements need to be interpreted in the context of esophageal body motility and highlights the importance of pre-operative screening for dysmotility. Future studies using standardized FLIP protocol and balloon size are needed. PMID:28275309

  13. Computed tomographic imaging characteristics of the normal canine lacrimal glands

    PubMed Central

    2014-01-01

    Background The canine lacrimal gland (LG) and accessory lacrimal gland of the third eyelid (TEG) are responsible for production of the aqueous portion of the precorneal tear film. Immune-mediated, toxic, neoplastic, or infectious processes can affect the glands directly or can involve adjacent tissues, with secondary gland involvement. Disease affecting these glands can cause keratoconjunctivitis sicca, corneal ulcers, and loss of vision. Due to their location in the orbit, these small structures are difficult to evaluate and measure, making cross-sectional imaging an important diagnostic tool. The detailed cross-sectional imaging appearance of the LG and TEG in dogs using computed tomography (CT) has not been reported to date. Results Forty-two dogs were imaged, and the length, width, and height were measured and the volume calculated for the LGs & TEGs. The glands were best visualized in contrast-enhanced CT images. The mean volume of the LG was 0.14 cm3 and the TEG was 0.1 cm3. The mean height, width, and length of the LG were, 9.36 mm, 4.29 mm, and 9.35 mm, respectively; the corresponding values for the TEG was 2.02 mm, 9.34 mm, and 7.90 mm. LG and TEG volume were positively correlated with body weight (p < 0.05). Conclusions Contrast-enhanced CT is a valuable tool for noninvasive assessment of canine lacrimal glands. PMID:24886364

  14. Marginal bone level in two Danish cross-sectional population samples in 1997-1998 and 2007-2008.

    PubMed

    Bahrami, Golnosh; Vaeth, Michael; Wenzel, Ann; Isidor, Flemming

    2018-04-12

    The aim of this study was to compare the marginal bone level of two randomly selected population samples from 1997/1998 and 2007/2008, with special emphasis on the role of smoking habits and gender. Two cross-sectional randomly selected population samples [1997/1998 (N = 616) and 2007/2008 (N = 396)] were analysed with respect to the marginal bone level. The marginal bone level was measured in full-mouth intraoral radiographs. Information on smoking was gathered using questionnaires. Multiple regression analysis was used in order to adjust for correlating factors (gender, age, smoking habits and number of teeth). After adjusting for confounding factors, the population sample from 2007/2008 had on average a slightly, but statistically significantly, more reduced average marginal bone level (0.15 mm) than the population sample from 1997/1998. Men had more reduced marginal bone level than women (0.12 mm). Smokers in both population samples had more reduced marginal bone level than non-smokers (0.39 mm and 0.12 mm for 1997/1998; 0.65 mm and 0.16 mm for 2007/2008). In these populations, sampled 10 years apart, the 2007/2008 population sample had a slightly more reduced marginal bone level than the 1997/1998 population sample. Men had more reduced marginal bone level than women, and smoking is considered a major risk factor for a reduced marginal bone level.

  15. Analysis of tracheid development in suppressed-growth Ponderosa Pine using the FPL ring profiler

    Treesearch

    C. Tim Scott; David W. Vahey

    2012-01-01

    The Ring Profiler was developed to examine the cross-sectional morphology of wood tracheids in a 12.5-mm core sample. The instrument integrates a specially designed staging apparatus with an optical imaging system to obtain high-contrast, high-resolution images containing about 200-500 tracheids. These images are further enhanced and analyzed to extract tracheid cross-...

  16. An intrahepatic calculus superimposed over the right renal shadow: a case of mistaken identity.

    PubMed

    Learney, Robert M; Shrotri, Nitin

    2010-08-01

    A 36-year-old Caucasian British woman presented with a classic case of right renal colic. Initial plain abdominal radiography and intravenous urography identified an 8 x 5 mm calculus apparently lying within a right lower pole calyx. Following failed extracorporeal lithotripsy and flexible ureterorenoscopy, cross-sectional imaging revealed a misdiagnosis by superposition of an intrahepatic calculus over the right renal shadow. This case serves to support cross-sectional imaging in the diagnosis of renal calculi. Copyright 2010 Elsevier Inc. All rights reserved.

  17. Computed tomographic and cross-sectional anatomy of the normal pacu (Colossoma macroponum).

    PubMed

    Carr, Alaina; Weber, E P Scott; Murphy, Chris J; Zwingenberger, Alison

    2014-03-01

    The purpose of this study was to compare and define the normal cross-sectional gross and computed tomographic (CT) anatomy for a species of boney fish to better gain insight into the use of advanced diagnostic imaging for future clinical cases. The pacu (Colossoma macropomum) was used because of its widespread presence in the aquarium trade, its relatively large body size, and its importance in the research and aquaculture settings. Transverse 0.6-mm CT images of three cadaver fish were obtained and compared to corresponding frozen cross sections of the fish. Relevant anatomic structures were identified and labeled at each level; the Hounsfield unit density of major organs was established. The images presented good anatomic detail and provide a reference for future research and clinical investigation.

  18. Dimensions of the scala tympani in the human and cat with reference to cochlear implants.

    PubMed

    Hatsushika, S; Shepherd, R K; Tong, Y C; Clark, G M; Funasaka, S

    1990-11-01

    The width, height, and cross-sectional area of the scala tympani in both the human and cat were measured to provide dimensional information relevant to the design of scala tympani electrode arrays. Both the height and width of the human scala tympani decreased rapidly within the first 1.5 mm from the round window. Thereafter, they exhibit a gradual reduction in their dimension with increasing distance from the round window. The cross-sectional area of the human scala tympani reflects the changes observed in both the height and width. In contrast, the cat scala tympani exhibits a rapid decrease in its dimensions over the first 6 to 8 mm from the round window. However, beyond this point the cat scala tympani also exhibits a more gradual decrease in its dimensions. Finally, the width of the scala tympani, in both human and cat, is consistently greater than the height.

  19. Traffic congestion and blood pressure elevation: A comparative cross-sectional study in Lebanon.

    PubMed

    Bou Samra, Patrick; El Tomb, Paul; Hosni, Mohammad; Kassem, Ahmad; Rizk, Robin; Shayya, Sami; Assaad, Sarah

    2017-12-01

    This comparative cross-sectional study examines the association between traffic congestion and elevation of systolic and/or diastolic blood pressure levels among a convenience sample of 310 drivers. Data collection took place during a gas station pause at a fixed time of day. Higher average systolic (142 vs 123 mm Hg) and diastolic (87 vs 78 mm Hg) blood pressures were detected among drivers exposed to traffic congestion compared with those who were not exposed (P<.001), while controlling for body mass index, age, sex, pack-year smoking, driving hours per week, and occupational driving. Moreover, among persons exposed to traffic congestion, longer exposure time was associated with higher systolic and diastolic blood pressures. Further studies are needed to better understand the mechanisms of the significant association between elevated blood pressure and traffic congestion. ©2017 Wiley Periodicals, Inc.

  20. Proportional drift tubes for large area muon detectors

    NASA Technical Reports Server (NTRS)

    Cho, C.; Higashi, S.; Hiraoka, N.; Maruyama, A.; Okusawa, T.; Sato, T.; Suwada, T.; Takahashi, T.; Umeda, H.

    1985-01-01

    A proportional drift chamber which consists of eight rectangular drift tubes with cross section of 10 cm x 5 cm, a sense wire of 100 micron phi gold-plated tungsten wire and the length of 6 m, was tested using cosmic ray muons. Spatial resolution (rms) is between 0.5 and 1 mm over drift space of 50 mm, depending on incident angle and distance from sense wire.

  1. Endoscopic optical coherence tomography with a modified microelectromechanical systems mirror for detection of bladder cancers

    NASA Astrophysics Data System (ADS)

    Xie, Tuqiang; Xie, Huikai; Fedder, Gary K.; Pan, Yingtian

    2003-11-01

    Experimental results of a modified micromachined microelectromechanical systems (MEMS) mirror for substantial enhancement of the transverse laser scanning performance of endoscopic optical coherence tomography (EOCT) are presented. Image distortion due to buckling of MEMS mirror in our previous designs was analyzed and found to be attributed to excessive internal stress of the transverse bimorph meshes. The modified MEMS mirror completely eliminates bimorph stress and the resultant buckling effect, which increases the wobbling-free angular optical actuation to greater than 37°, exceeding the transverse laser scanning requirements for EOCT and confocal endoscopy. The new optical coherence tomography (OCT) endoscope allows for two-dimensional cross-sectional imaging that covers an area of 4.2 mm × 2.8 mm (limited by scope size) and at roughly 5 frames/s instead of the previous area size of 2.9 mm × 2.8 mm and is highly suitable for noninvasive and high-resolution imaging diagnosis of epithelial lesions in vivo. EOCT images of normal rat bladders and rat bladder cancers are compared with the same cross sections acquired with conventional bench-top OCT. The results clearly demonstrate the potential of EOCT for in vivo imaging diagnosis and precise guidance for excisional biopsy of early bladder cancers.

  2. Advanced Antennas Enabled by Electromagnetic Metamaterials

    DTIC Science & Technology

    2014-12-01

    radiation patterns of a conical horn antenna and three soft horns with various homogeneous metasurface liners. The maximum cross-polarization level was...inhomogencous metasurface liners covering both the flared horn section and the straight waveguide section. The mctahorn is fed by a circular waveguide...with a diameter of 20 mm. (b) The sizes of the metallic patches at each row of the metasurface in the flared horn section. Both the length and width

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bolotnikov, A. E., E-mail: bolotnik@bnl.gov; Camarda, G. S.; Cui, Y.

    We investigated the feasibility of long-drift-time CdZnTe (CZT) gamma-ray detectors, fabricated from CZT material produced by Redlen Technologies. CZT crystals with cross-section areas of 5 × 5 mm{sup 2} and 6 × 6 mm{sup 2} and thicknesses of 20-, 30-, 40-, and 50-mm were configured as 3D position-sensitive drift detectors and were read out using a front-end ASIC. By correcting the electron charge losses caused by defects in the crystals, we demonstrated high performance for relatively thick detectors fabricated from unselected CZT material.

  4. Influence of specimen dimensions on ductile-to-brittle transition temperature in Charpy impact test

    NASA Astrophysics Data System (ADS)

    Rzepa, S.; Bucki, T.; Konopík, P.; Džugan, J.; Rund, M.; Procházka, R.

    2017-02-01

    This paper discusses the correlation between specimen dimensions and transition temperature. Notch toughness properties of Standard Charpy-V specimens are compared to samples with lower width (7.5 mm, 5 mm, 2.5 mm) and sub-size Charpy specimens with cross section 3×4. In this study transition curves are correlated with lateral ductile part of fracture related ones for 5 considered geometries. Based on the results obtained, correlation procedure for transition temperature determination of full size specimens defined by fracture appearance of sub-sized specimens is proposed.

  5. Measurement of differential cross sections and spin density matrix elements along with a partial wave analysis for gammap → po using CLAS at Jefferson Lab

    NASA Astrophysics Data System (ADS)

    Williams, Mike

    This work presents measurements of differential cross sections, dsigma/dcos qwCM , and spin density matrix elements, r0MM' , for the reaction gammap → po in the energy range 1.72 GeV< s <2.84 GeV. The data were collected at Jefferson Lab, using the CLAS detector, as part of the g11a run period in 2004. Our r0MM' measurements vastly increase the precision of the world's data and extend the large angle measurements by over 400 MeV in s . Our data confirms that for s < 2.1 GeV, the forward angle (small |t|) production amplitude is dominated by t-channel pi0 exchange. At higher energies, existing non-resonant models do a poor job of describing our data. In particular, u-channel models fail to reproduce our highest energy backwards r0MM' measurements. A mass-independent partial wave analysis has also been performed. Near threshold, the dominant resonance contributions extracted are the **** F15 (1680) and *** D 13(1700). Together with the t-channel pi0 exchange, these three waves provide a remarkably good description of our differential cross section and spin density matrix element measurements for s < 2 GeV. Strong, but not conclusive, evidence for the **** G17(2190) has also been extracted. Improved non-resonant models may be necessary to irrefutably show whether this state contributes to o photoproduction. Evidence for missing resonances is suggestive, but inconclusive without theoretical input.

  6. Microstructure and mechanical properties of 2.5 vol. % TiBw/Ti6Al4V composites plates fabricated by hot-hydrostatic canned extrusion

    NASA Astrophysics Data System (ADS)

    Zhang, Wencong; Zhang, Lingjia; Feng, Yangju; Cui, Guorong; Chen, Wenzhen

    2018-04-01

    Plates of 2.5 vol. % TiB whisker-reinforced Ti6Al4V titanium matrix composites (TiBw/Ti64) with network structure were successfully fabricated by hot-hydrostatic extrusion with steel cup at 1100 °C. The dimensions of plates were about 150mm in length, 27mm in width and 2mm in thickness. After extrusion, the original equiaxed-network structure formed by TiB whiskers still existed, but was compressed in cross-section and stretched in longitudinal section and then the TiB whiskers were directional distribution along the extrusion direction. Furthermore, the mechanical properties results showed that the strength, hardness and ductility of the plates were significantly improved compared to as-sintered composites.

  7. [Localization of upper airway stricture by CT scan in patients with obstructive sleep apnea syndrome during drug-induced sleeping].

    PubMed

    Hu, Ji-bo; Hu, Hong-jie; Hou, Tie-ning; Gao, Hang-xiang; He, Jian

    2010-03-01

    To evaluate the feasibility of multi-slice spiral CT scan to localize upper airway stricture in patients with obstructive sleep apnea syndrome (OSAS) during drug-induced sleeping. One hundred and fourteen patients diagnosed as OSAS by polysomnography were included in the study. Multi-slice spiral CT scan covering upper airway was performed at the end of inspiration and clear upper airway images were obtained in waking. After injecting 5 mg of midazolam intravenously slowly in 109 patients, CT scan was performed at apnea and clear upper airway images were obtained in sleeping. Cross-section area and minimal diameter of airway were measured and the parameters were compared under those two states. Upper airway was displayed intuitionisticly by using post-processing techniques. One hundred and nine patients with OSAS finished the examination with a success rate of 100 %. Airway obstruction at retropalatal level was observed in 62 patients, among whom 26 were associated with airway obstruction at retroglossal level, 27 with narrower airway at retroglossal level in sleeping compared with that in waking, and 9 with no significant change of the airway at retroglossal level after sleeping. Narrower airway at retropalatal level in sleeping compared with that in waking was observed in 40 patients, among whom 20 were associated with narrower airway at retroglossal level in sleeping compared with that in waking, 10 with complete airway obstruction at retroglossal level in sleeping, and 7 with no significant change of the airway at both retropalatal and retroglossal levels before and after sleeping. Minimal mean cross-section area of airway at retropalatal level was (72.60 +/-45.15)mm(2) in waking and (8.26 +/-18.16)mm(2) in sleeping; and minimal mean cross-section area of airway at retroglossal level was (133.21 +/-120.36)mm(2)in waking and (16.73 +/-30.21)mm(2) in sleeping (P <0.01). Minimal mean diameter of airway at retropalatal level was (6.91 +/-2.23) mm in waking and (1.18 +/-2.14) mm in sleeping; and minimal mean diameter of airway at retroglossal level was (8.68 +/-4.32) mm in waking and (1.68 +/-2.22) mm in sleeping (P <0.01). Multi-slice spiral CT with post-processing techniques can display the shape of the upper airway in patients with OSAS in sleeping, and can localize the upper airway stricture and assess its range accurately.

  8. Remote Raman Efficiencies and Cross-Sections of Organic and Inorganic Chemicals.

    PubMed

    Acosta-Maeda, Tayro E; Misra, Anupam K; Porter, John N; Bates, David E; Sharma, Shiv K

    2017-05-01

    We determined Raman cross-sections of various organic liquids and inorganic polyatomic ions in aqueous solutions with a 532 nm pulsed laser using remote Raman systems developed at the University of Hawaii. Using a calibrated integrating sphere as a light source, we converted the intensity counts in the spectrum of the light from the integrating sphere measured with UH remote Raman instrument to spectral radiance. From these data, a response function of the remote Raman instrument was obtained. With the intensity-calibrated instrument, we collected remote Raman data from a standard 1 mm path length fused silica spectrophotometer cell filled with cyclohexane. The measured value of the differential Raman cross-section for the 801 cm -1 vibrational mode of cyclohexane is 4.55 × 10 -30 cm 2 sr -1 molecule -1 when excited by a 532 nm laser, in good agreement with the values reported in the literature. Using the measured cyclohexane Raman cross-section as a reference and relative Raman mode intensities of the various ions and organic liquids, we calculated the Raman cross-sections of the strongest Raman lines of nitrate, sulfate, carbonate, phosphate ions, and organic liquids by maintaining same experimental conditions for remote Raman detection. These relative Raman cross-section values will be useful for estimating detection capabilities of remote Raman systems for planetary exploration.

  9. Predicting the bending properties of long bones: Insights from an experimental mouse model.

    PubMed

    Peacock, Sarah J; Coats, Brittney R; Kirkland, J Kyle; Tanner, Courtney A; Garland, Theodore; Middleton, Kevin M

    2018-03-01

    Analyses of bone cross-sectional geometry are frequently used by anthropologists and paleontologists to infer the loading histories of past populations. To address some underlying assumptions, we investigated the relative roles of genetics and exercise on bone cross-sectional geometry and bending mechanics in three mouse strains: high bone density (C3H/He), low bone density (C57BL/6), and a high-runner strain homozygous for the Myh4 Minimsc allele (MM). Weanlings of each strain were divided into exercise (wheel) or control (sedentary) treatment groups for a 7-week experimental period. Morphometrics of the femoral mid-diaphysis and mechanical testing were used to assess both theoretical and ex vivo bending mechanics. Across all measured morphological and bending traits, we found relatively small effects of exercise treatment compared to larger and more frequent interstrain differences. In the exercised group, total distance run over the experimental period was not a predictor of any morphological or bending traits. Cross-sectional geometry did not accurately predict bone response to loading. Results from this experimental model do not support hypothesized associations among extreme exercise, cross-sectional geometry, and bending mechanics. Our results suggest that analysis of cross-sectional geometry alone is insufficient to predict loading response, and questions the common assumption that cross-sectional geometry differences are indicative of differential loading history. © 2017 Wiley Periodicals, Inc.

  10. Does a conservative tibial cut in conventional total knee arthroplasty violate the deep medial collateral ligament?

    PubMed

    Maes, Michael; Luyckx, Thomas; Bellemans, Johan

    2014-11-01

    Based on the anatomy of the deep medial collateral ligament (MCL), it was hypothesized that at least part of its cross-sectional insertion area is jeopardized while performing a standard tibial cut in conventional total knee arthroplasty (TKA). The aim of this study was to determine whether it is anatomically possible to preserve the tibial deep MCL insertion during conventional TKA. Thirty-three unpaired cadaveric knee specimens were used for this study. Knees with severe varus/valgus deformity or damage to the medial structures of the knee were excluded. In the first part of the study, the dimensions of the tibial insertion of the deep MCL and its relationship to the joint line were recorded. Next, the cross-sectional area of the deep MCL insertion was determined using calibrated digital photographic analysis. In the second part, the effect of a standard 9-mm 3° sloped tibial cut on the structural integrity of the deep MCL cross-sectional insertion area was determined using conventional instrumentation. The proximal border of the deep MCL insertion site on the tibia was located on average 4.7 ± 1.2 mm distally to the joint line. After performing a standard 9-mm 3° sloped tibial cut, on average 54% of the deep MCL insertion area was resected. In 29% of the cases, the deep MCL insertion area was completely excised. The deep MCL cannot routinely be preserved in conventional TKA. The deep MCL insertion is at risk and may be jeopardized in case of a tibial cut 9 mm below the native joint line. As the deep MCL is a distinct medial stabilizer and plays an important role in rotational stability, this may have implications in future designs of both unicondylar and total knee arthroplasty, but further research is necessary.

  11. Inelastic neutron scattering from {sup 238}U

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moxon, M.C.; Wartena, J.A.; Weigmann, H.

    1994-12-31

    A measurement of the neutron inelastic scattering cross-section of {sup 238}U at 4 distant neutron energies in the low keV region has been undertaken using a 30m flight path on the pulsed neutron source GELINA. The scattered neutrons are detected in a plastic scintillator after passing through a 270 mm iron filter. The values obtained for the cross-section to the first excited 2{sup +} state in {sup 238}U are 293{+-}31, 660{+-}296, 978{+-}73 and 1176{+-}95 mb at neutron energies of 68.2, 126.6, 182.4 and 213.6 keV respectively.

  12. Mechanical behaviour of cerclage material consisting of silicon rubber.

    PubMed

    Hinrichsen, G; Eberhardt, A; Springer, H

    1979-09-01

    Silicon rubber specimens of circular or rectangular cross-section (cross-section area between ca. 2 and 7 mm2) are used as cerclage bands. A series of commercial cerclage elements was investigated for mechanical characteristics, such as stress-strain behaviour and modulus of elasticity, using a tensile-testing machine. Large differences in these properties exist among the various specimens. Moreover, time-dependent effects, such as stress-relaxation, retardation, and creep, were analysed by the present investigations. One has to take into consideration that the initial length and stress of the cerclage band vary significantly with time after the operation.

  13. Effect of Class III bone anchor treatment on airway.

    PubMed

    Nguyen, Tung; De Clerck, Hugo; Wilson, Michael; Golden, Brent

    2015-07-01

    To compare airway volumes and minimum cross-section area changes of Class III patients treated with bone-anchored maxillary protraction (BAMP) versus untreated Class III controls. Twenty-eight consecutive skeletal Class III patients between the ages of 10 and 14 years (mean age, 11.9 years) were treated using Class III intermaxillary elastics and bilateral miniplates (two in the infra-zygomatic crests of the maxilla and two in the anterior mandible). The subjects had cone beam computed tomographs (CBCTs) taken before initial loading (T1) and 1 year out (T2). Twenty-eight untreated Class III patients (mean age, 12.4 years) had CBCTs taken and cephalograms generated. The airway volumes and minimum cross-sectional area measurements were performed using Dolphin Imaging 11.7 3D software. The superior border of the airway was defined by a plane that passes through the posterior nasal spine and basion, while the inferior border included the base of the epiglottis to the lower border of C3. From T1 to T2, airway volume from BAMP-treated subjects showed a statistically significant increase (1499.64 mm(3)). The area in the most constricted section of the airway (choke point) increased slightly (15.44 mm(2)). The airway volume of BAMP patients at T2 was 14136.61 mm(3), compared with 14432.98 mm(3) in untreated Class III subjects. Intraexaminer correlation coefficients values and 95% confidence interval values were all greater than .90, showing a high degree of reliability of the measurements. BAMP treatment did not hinder the development of the oropharynx.

  14. Absolute OH Number Density Measurements in Lean Fuel-Air Mixtures Excited by a Repetitively Pulsed Nanosecond Discharge

    DTIC Science & Technology

    2013-01-01

    cross section quartz channel with wall thickness of 1.75 mm. Two plane quartz windows are fused to the ends of the channel at Brewster angle (for ~308...ttp :// ar c. ai aa .o rg | D O I: 1 0. 25 14 /6 .2 01 3- 43 2 4 about 1 J/pulse, softly focused over the flame using a lens with a focal...region with an f=550 mm lens . The LIF signal sampling volume was about 100 mm away from the laser focal point, to avoid transition saturation. The

  15. Targeted vertical cross-sectional imaging with handheld near-infrared dual axes confocal fluorescence endomicroscope.

    PubMed

    Qiu, Zhen; Liu, Zhongyao; Duan, Xiyu; Khondee, Supang; Joshi, Bishnu; Mandella, Michael J; Oldham, Kenn; Kurabayashi, Katsuo; Wang, Thomas D

    2013-02-01

    We demonstrate vertical cross-sectional (XZ-plane) images of near-infrared (NIR) fluorescence with a handheld dual axes confocal endomicroscope that reveals specific binding of a Cy5.5-labeled peptide to pre-malignant colonic mucosa. This view is perpendicular to the tissue surface, and is similar to that used by pathologists. The scan head is 10 mm in outer diameter (OD), and integrates a one dimensional (1-D) microelectromechanical systems (MEMS) X-axis scanner and a bulky lead zirconate titanate (PZT) based Z-axis actuator. The microscope images in a raster-scanning pattern with a ±6 degrees (mechanical) scan angle at ~3 kHz in the X-axis (fast) and up to 10 Hz (0-400 μm) in the Z-axis (slow). Vertical cross-sectional fluorescence images are collected with a transverse and axial resolution of 4 and 5 μm, respectively, over a field-of-view of 800 μm (width) × 400 μm (depth). NIR vertical cross-sectional fluorescence images of fresh mouse colonic mucosa demonstrate histology-like imaging performance with this miniature instrument.

  16. Targeted vertical cross-sectional imaging with handheld near-infrared dual axes confocal fluorescence endomicroscope

    PubMed Central

    Qiu, Zhen; Liu, Zhongyao; Duan, Xiyu; Khondee, Supang; Joshi, Bishnu; Mandella, Michael J.; Oldham, Kenn; Kurabayashi, Katsuo; Wang, Thomas D.

    2013-01-01

    We demonstrate vertical cross-sectional (XZ-plane) images of near-infrared (NIR) fluorescence with a handheld dual axes confocal endomicroscope that reveals specific binding of a Cy5.5-labeled peptide to pre-malignant colonic mucosa. This view is perpendicular to the tissue surface, and is similar to that used by pathologists. The scan head is 10 mm in outer diameter (OD), and integrates a one dimensional (1-D) microelectromechanical systems (MEMS) X-axis scanner and a bulky lead zirconate titanate (PZT) based Z-axis actuator. The microscope images in a raster-scanning pattern with a ±6 degrees (mechanical) scan angle at ~3 kHz in the X-axis (fast) and up to 10 Hz (0–400 μm) in the Z-axis (slow). Vertical cross-sectional fluorescence images are collected with a transverse and axial resolution of 4 and 5 μm, respectively, over a field-of-view of 800 μm (width) × 400 μm (depth). NIR vertical cross-sectional fluorescence images of fresh mouse colonic mucosa demonstrate histology-like imaging performance with this miniature instrument. PMID:23412564

  17. SU-E-I-25: Quantification of Coronary Artery Cross-Sectional Area in CT Angiography Using Integrated Density: A Simulation Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, T; Ding, H; Lipinski, J

    2015-06-15

    Purpose: To develop a physics-based model for accurate quantification of the cross-sectional area (CSA) of coronary arteries in CT angiography by measuring the integrated density to account for the partial volume effect. Methods: In this technique the integrated density of the object as compared with its local background is measured to account for the partial volume effect. Normal vessels were simulated as circles with diameters in the range of 0.1–3mm. Diseased vessels were simulated as 2, 3, and 4mm diameter vessels with 10–90% area stenosis, created by inserting circular plaques. A simplified two material model was used with the lumenmore » as 8mg/ml Iodine and background as lipid. The contrast-to-noise ratio between lumen and background was approximately 26. Linear fits to the known CSA were calculated. The precision and accuracy of the measurement were quantified using the root-mean-square fit deviations (RMSD) and errors to the known CSA (RMSE). Results compared to manual segmentation of the vessel lumen. To assess the impact of random variations, coefficients of variation (CV) from 10 simulations for each vessel were computed to determine reliability. Measurements with CVs less than 10% were considered reliable. Results: For normal vessels, the precision and accuracy of the integrated density technique were 0.12mm{sup 2} and 0.28mm{sup 2}, respectively. The corresponding results for manual segmentation were 0.27mm{sup 2} and 0.43mm{sup 2}. For diseased vessels, the precision and accuracy of the integrated density technique were 0.14mm{sup 2} and 0.19mm{sup 2}. Corresponding results for manual segmentation were 0.42mm{sup 2} and 0.71mm{sup 2}. Reliable CSAs were obtained for normal vessels with diameters larger than 1 mm and for diseased vessels with area as low as 1.26mm2. Conclusion: The CSA based on integrated density showed improved precision and accuracy as compared with manual segmentation in simulation. These results indicate the potential of using integrated density to quantify CSA of coronary arteries in CT angiography.« less

  18. An analytical model to design circumferential clasps for laser-sintered removable partial dentures.

    PubMed

    Alsheghri, Ammar A; Alageel, Omar; Caron, Eric; Ciobanu, Ovidiu; Tamimi, Faleh; Song, Jun

    2018-06-21

    Clasps of removable partial dentures (RPDs) often suffer from plastic deformation and failure by fatigue; a common complication of RPDs. A new technology for processing metal frameworks for dental prostheses based on laser-sintering, which allows for precise fabrication of clasp geometry, has been recently developed. This study sought to propose a novel method for designing circumferential clasps for laser-sintered RPDs to avoid plastic deformation or fatigue failure. An analytical model for designing clasps with semicircular cross-sections was derived based on mechanics. The Euler-Bernoulli elastic curved beam theory and Castigliano's energy method were used to relate the stress and undercut with the clasp length, cross-sectional radius, alloy properties, tooth type, and retention force. Finite element analysis (FEA) was conducted on a case study and the resultant tensile stress and undercut were compared with the analytical model predictions. Pull-out experiments were conducted on laser-sintered cobalt-chromium (Co-Cr) dental prostheses to validate the analytical model results. The proposed circumferential clasp design model yields results in good agreement with FEA and experiments. The results indicate that Co-Cr circumferential clasps in molars that are 13mm long engaging undercuts of 0.25mm should have a cross-section radius of 1.2mm to provide a retention of 10N and to avoid plastic deformation or fatigue failure. However, shorter circumferential clasps such as those in premolars present high stresses and cannot avoid plastic deformation or fatigue failure. Laser-sintered Co-Cr circumferential clasps in molars are safe, whereas they are susceptible to failure in premolars. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

  19. Numerical simulation of flow and melting characteristics of seawater-ice crystals two-phase flow in inlet straight pipe of shell and tube heat exchanger of polar ship

    NASA Astrophysics Data System (ADS)

    Xu, Li; Huang, Chang-Xu; Huang, Zhen-Fei; Sun, Qiang; Li, Jie

    2018-05-01

    The ice crystal particles are easy to enter into the seawater cooling system of polar ship together with seawater when it sails in the Arctic. They are easy to accumulate in the pipeline, causing serious blockage of the cooling pipe. In this study, the flow and melting characteristics of ice particles-seawater two-phase flow in inlet straight pipe of shell-and-tube heat exchanger were numerically simulated by using Eulerian-Eulerian two-fluid model coupled with the interphase heat and mass transfer model. The influences of inlet ice packing factor, ice crystal particle diameter, and inlet velocity on the distribution and melting characteristics of ice crystals were investigated. The degree of asymmetry of the distribution of ice crystals in the cross section decreases gradually when the IPF changes from 5 to 15%. The volume fractions of ice crystals near the top of the outlet cross section are 19.59, 19.51, and 22.24% respectively for ice packing factor of 5, 10 and 15%. When the particle diameter is 0.5 mm, the ice crystals are gradually stratified during the flow process. With particle diameters of 1.0 and 2.0 mm, the region with the highest volume fraction of ice crystals is a small circle and the contours in the cloud map are compact. The greater the inlet flow velocity, the less stratified the ice crystals and the more obvious the turbulence on the outlet cross section. The average volume fraction of ice crystals along the flow direction is firstly rapidly reduced and then stabilized after 300 mm.

  20. A look inside the nerve - Morphology of nerve fascicles in healthy controls and patients with polyneuropathy.

    PubMed

    Grimm, Alexander; Winter, Natalie; Rattay, Tim W; Härtig, Florian; Dammeier, Nele M; Auffenberg, Eva; Koch, Marilin; Axer, Hubertus

    2017-12-01

    Polyneuropathies are increasingly analyzed by ultrasound. Summarizing, diffuse enlargement is typical in Charcot-Marie Tooth type 1 (CMT1a), regional enlargement occurs in inflammatory neuropathies. However, a distinction of subtypes is still challenging. Therefore, this study focused on fascicle size and pattern in controls and distinct neuropathies. Cross-sectional area (CSA) of the median, ulnar and peroneal nerve (MN, UN, PN) was measured at predefined landmarks in 50 healthy controls, 15 CMT1a and 13 MMN patients. Additionally, largest fascicle size and number of visible fascicles was obtained at the mid-upper arm cross-section of the MN and UN and in the popliteal fossa cross-section of the PN. Cut-off normal values for fascicle size in the MN, UN and PN were defined (<4.8mm 2 , <2.8mm 2 and <3.5mm 2 ). In CMT1a CSA and fascicle values are significantly enlarged in all nerves, while in MMN CSA and fascicles are regionally enlarged with predominance in the upper arm nerves. The ratio of enlarged fascicles and all fascicles was significantly increased in CMT1a (>50%) in all nerves (p<0.0001), representing diffuse fascicle enlargement, and moderately increased in MMN (>20%), representing differential fascicle enlargement (enlarged and normal fascicles at the same location) sparing the peroneal nerve (regional fascicle enlargement). Based on these findings distinct fascicle patterns were defined. Normal values for fascicle size could be evaluated; while CMT1a features diffuse fascicle enlargement, MMN shows regional and differential predominance with enlarged fascicles as single pathology. Pattern analysis of fascicles might facilitate distinction of several otherwise similar neuropathies. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  1. Investigation and Taguchi Optimization of Microbial Fuel Cell Salt Bridge Dimensional Parameters

    NASA Astrophysics Data System (ADS)

    Sarma, Dhrupad; Barua, Parimal Bakul; Dey, Nabendu; Nath, Sumitro; Thakuria, Mrinmay; Mallick, Synthia

    2018-01-01

    One major problem of two chamber salt bridge microbial fuel cells (MFCs) is the high resistance offered by the salt bridge to anion flow. Many researchers who have studied and optimized various parameters related to salt bridge MFC, have not shed much light on the effect of salt bridge dimensional parameters on the MFC performance. Therefore, the main objective of this research is to investigate the effect of length and cross sectional area of salt bridge and the effect of solar radiation and atmospheric temperature on MFC current output. An experiment has been designed using Taguchi L9 orthogonal array, taking length and cross sectional area of salt bridge as factors having three levels. Nine MFCs were fabricated as per the nine trial conditions. Trials were conducted for 3 days and output current of each of the MFCs along with solar insolation and atmospheric temperature were recorded. Analysis of variance shows that salt bridge length has significant effect both on mean (with 53.90% contribution at 95% CL) and variance (with 56.46% contribution at 87% CL), whereas the effect of cross sectional area of the salt bridge and the interaction of these two factors is significant on mean only (with 95% CL). Optimum combination was found at 260 mm salt bridge length and 506.7 mm2 cross sectional area with 4.75 mA of mean output current. The temperature and solar insolation data when correlated with each of the MFCs average output current, revealed that both external factors have significant impact on MFC current output but the correlation coefficient varies from MFC to MFC depending on salt bridge dimensional parameters.

  2. Study of the Integration of the CNU-TS-1 Mobile Tunnel Monitoring System.

    PubMed

    Du, Liming; Zhong, Ruofei; Sun, Haili; Zhu, Qiang; Zhang, Zhen

    2018-02-01

    A rapid, precise and automated means for the regular inspection and maintenance of a large number of tunnels is needed. Based on the depth study of the tunnel monitoring method, the CNU-TS-1 mobile tunnel monitoring system (TS1) is developed and presented. It can efficiently obtain the cross-sections that are orthogonal to the tunnel in a dynamic way, and the control measurements that depend on design data are eliminated. By using odometers to locate the cross-sections and correcting the data based on longitudinal joints of tunnel segment lining, the cost of the system has been significantly reduced, and the interval between adjacent cross-sections can reach 1-2 cm when pushed to collect data at a normal walking speed. Meanwhile, the relative deformation of tunnel can be analyzed by selecting cross-sections from original data. Through the measurement of the actual tunnel, the applicability of the system for tunnel deformation detection is verified, and the system is shown to be 15 times more efficient than that of the total station. The simulation experiment of the tunnel deformation indicates that the measurement accuracy of TS1 for cross-sections is 1.1 mm. Compared with the traditional method, TS1 improves the efficiency as well as increases the density of the obtained points.

  3. Near-threshold NN→dπ reaction in chiral perturbation theory

    NASA Astrophysics Data System (ADS)

    Gårdestig, A.; Phillips, D. R.; Elster, Ch.

    2006-02-01

    The near-threshold np→dπ0 cross section is calculated in chiral perturbation theory to next-to-leading order in the expansion parameter √(Mmπ)/Λχ. At this order irreducible pion loops contribute to the relevant pion-production operator. Although their contribution to this operator is finite, considering initial- and final-state distortions produces a linear divergence in its matrix elements. We renormalize this divergence by introducing a counterterm, whose value we choose to reproduce the threshold np→dπ0 cross section measured at TRIUMF. The energy dependence of this cross section is then predicted in chiral perturbation theory, being determined by the production of p-wave pions, and also by energy dependence in the amplitude for the production of s-wave pions. With an appropriate choice of the counterterm, the chiral prediction for this energy dependence converges well.

  4. Vastus medialis cross-sectional area is positively associated with patella cartilage and bone volumes in a pain-free community-based population

    PubMed Central

    Berry, Patricia A; Teichtahl, Andrew J; Galevska-Dimitrovska, Ana; Hanna, Fahad S; Wluka, Anita E; Wang, Yuanyuan; Urquhart, Donna M; English, Dallas R; Giles, Graham G; Cicuttini, Flavia M

    2008-01-01

    Introduction Although vastus medialis and lateralis are important determinants of patellofemoral joint function, their relationship with patellofemoral joint structure is unknown. The aim of this study was to examine potential determinants of vastus medialis and lateralis cross-sectional areas and the relationship between the cross-sectional area and patella cartilage and bone volumes. Methods Two hundred ninety-seven healthy adult subjects had magnetic resonance imaging of their dominant knee. Vastus medialis and lateralis cross-sectional areas were measured 37.5 mm superior to the quadriceps tendon insertion at the proximal pole of the patella. Patella cartilage and bone volumes were measured from these images. Demographic data and participation in vigorous physical activity were assessed by questionnaire. Results The determinants of increased vastus medialis and lateralis cross-sectional areas were older age (P ≤ 0.002), male gender (P < 0.001), and greater body mass index (P ≤ 0.07). Participation in vigorous physical activity was positively associated with vastus medialis cross-sectional area (regression coefficient [beta] 90.0; 95% confidence interval [CI] 38.2, 141.7) (P < 0.001) but not with vastus lateralis cross-sectional area (beta 10.1; 95% CI -18.1, 38.3) (P = 0.48). The cross-sectional area of vastus medialis only was positively associated with patella cartilage volume (beta 0.6; 95% CI 0.23, 0.94) (P = 0.001) and bone volume (beta 3.0; 95% CI 1.40, 4.68) (P < 0.001) after adjustment for potential confounders. Conclusions Our results in a pain-free community-based population suggest that increased cross-sectional area of vastus medialis, which is associated with vigorous physical activity, and increased patella cartilage and bone volumes may benefit patellofemoral joint health and reduce the long-term risk of patellofemoral pathology. PMID:19077298

  5. Root elongation against a constant force: experiment with a computerized feedback-controlled device

    NASA Technical Reports Server (NTRS)

    Kuzeja, P. S.; Lintilhac, P. M.; Wei, C.

    2001-01-01

    Axial force was applied to the root tip of corn (Zea mays L. cv. Merit) seedlings using a computerized, feedback-controlled mechanical device. The system's feedback capability allowed continuous control of a constant tip load, and the attached displacement transducer provided the time course of root elongation. Loads up to 7.5 g decreased the root elongation rate by 0.13 mm h-1 g-1, but loads 7.5 to 17.5 g decreased the growth rate by only 0.04 mm h-1 g-1. Loads higher than 18 g stopped root elongation completely. Measurement of the cross-sectional areas of the root tips indicated that the 18 g load had applied about 0.98 MPa of axial pressure to the root, thereby exceeding the root's ability to respond with increased turgor pressure. Recorded time-lapse images of loaded roots showed that radial thickening (swelling) occurred behind the root cap, whose cross-sectional area increased with tip load.

  6. Difference in normal values of median nerve cross-sectional area between Dutch and Indian subjects.

    PubMed

    Burg, Ellen Walhout-van; Bathala, Lokesh; Visser, Leo H

    2014-07-01

    Ultrasound (US) measurement of the median nerve cross-sectional area (CSA) at the wrist is a useful diagnostic test for carpal tunnel syndrome (CTS). We compared median nerve normal values between samples of Indian and Dutch populations. The median nerve was examined by US at the wrist in 100 healthy volunteers in India and 137 volunteers in The Netherlands using the same protocol. Median nerve CSA at the wrist (7.0 ± 1.1 mm(2)) in the Indian cohort was lower in comparison to the Dutch cohort (8.3 ± 1.9 mm(2) ; P < 0.05). This difference was still present after controlling for age, height, and weight (P = 0.001). CSA normal values for the median nerve were different between the examined population samples even after correcting for age, height, and weight. This enforces the idea that laboratories around the world should obtain their own normative data. Copyright © 2013 Wiley Periodicals, Inc.

  7. Neutron resonance spectroscopy for the characterization of materials and objects

    NASA Astrophysics Data System (ADS)

    Schillebeeckx, P.; Borella, A.; Emiliani, F.; Gorini, G.; Kockelmann, W.; Kopecky, S.; Lampoudis, C.; Moxon, M.; Perelli Cippo, E.; Postma, H.; Rhodes, N. J.; Schooneveld, E. M.; Van Beveren, C.

    2012-03-01

    The resonance structure in neutron induced reaction cross sections can be used to determine the elemental compositions of materials or objects. The occurrence of resonances is the basis of neutron resonance capture analysis (NRCA) and neutron resonance transmission analysis (NRTA). NRCA and NRTA are fully non-destructive methods to determine the bulk elemental composition without the need of any sample preparation and resulting in a negligible residual activity. They have been applied to determine the elemental composition of archaeological objects and to characterize reference materials used for cross section measurements. For imaging applications a position sensitive neutron detector has been developed within the ANCIENT CHARM project. The detector is based on a 10 × 10 array of 6Li-glass scintillators mounted on a pitch of 2.5 mm, resulting in a 25 × 25 mm2 active area. The detector has been tested at the time-of-flight facility GELINA and used at the ISIS spallation source to study cultural heritage objects.

  8. A grillage model for predicting wrinkles in annular graphene under circular shearing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Z.; Duan, W. H.; Wang, C. M.

    This paper is concerned with a Timoshenko grillage model for modeling the wrinkling phenomenon in annular graphene under circular shearing applied at its inner edge. By calibrating the grillage model results against the molecular mechanics (MM) results, the grillage model comprising beams of elliptical cross-section orientated along the carbon-carbon bond has section dimensions of 0.06 nm for the major axis length and 0.036 nm for the minor axis length. Moreover, the beams are connected to one another at 0.00212 nm from the geometric centric. This eccentric connection of beams allows the proposed grillage model to cater for the cross-couplings amongmore » bonds that produce the out-of-plane wrinkling pattern. The out-of-plane to in-plane bending stiffnesses' ratio is 0.36, and the cross bending stiffness provided by the ellipse eccentricity is 0.025 times that of the in-plane bending stiffness. Besides furnishing identical wave numbers as well as amplitudes and wavelengths that are in good agreement with MM results, the grillage model can capture wrinkling patterns with a boundary layer, whereas plate and membrane models could not mimic the boundary layer.« less

  9. A Quantitative Assessment of Lip Movements in Different Facial Expressions Through 3-Dimensional on 3-Dimensional Superimposition: A Cross-Sectional Study.

    PubMed

    Gibelli, Daniele; Codari, Marina; Pucciarelli, Valentina; Dolci, Claudia; Sforza, Chiarella

    2017-11-23

    The quantitative assessment of facial modifications from mimicry is of relevant interest for the rehabilitation of patients who can no longer produce facial expressions. This study investigated a novel application of 3-dimensional on 3-dimensional superimposition for facial mimicry. This cross-sectional study was based on 10 men 30 to 40 years old who underwent stereophotogrammetry for neutral, happy, sad, and angry expressions. Registration of facial expressions on the neutral expression was performed. Root mean square (RMS) point-to-point distance in the labial area was calculated between each facial expression and the neutral one and was considered the main parameter for assessing facial modifications. In addition, effect size (Cohen d) was calculated to assess the effects of labial movements in relation to facial modifications. All participants were free from possible facial deformities, pathologies, or trauma that could affect facial mimicry. RMS values of facial areas differed significantly among facial expressions (P = .0004 by Friedman test). The widest modifications of the lips were observed in happy expressions (RMS, 4.06 mm; standard deviation [SD], 1.14 mm), with a statistically relevant difference compared with the sad (RMS, 1.42 mm; SD, 1.15 mm) and angry (RMS, 0.76 mm; SD, 0.45 mm) expressions. The effect size of labial versus total face movements was limited for happy and sad expressions and large for the angry expression. This study found that a happy expression provides wider modifications of the lips than the other facial expressions and suggests a novel procedure for assessing regional changes from mimicry. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Micro-Computed Tomography Analysis of the Root Canal Morphology of Palatal Roots of Maxillary First Molars.

    PubMed

    Marceliano-Alves, Marília; Alves, Flávio Rodrigues Ferreira; Mendes, Daniel de Melo; Provenzano, José Claudio

    2016-02-01

    A thorough knowledge of root canal anatomy is critical for successful root canal treatments. This study evaluated the internal anatomy of the palatal roots of maxillary first molars with micro-computed tomography (microCT). The palatal roots of extracted maxillary first molars (n = 169) were scanned with microCT to determine several anatomic parameters, including main canal classification, lateral canal occurrence and location, degree of curvature, main foramen position, apical constriction presence, diameters 1 and 2 mm from the apex and 1 mm from the foramen, minor dentin thickness in those regions, canal volume, surface area, and convexity. All canals were classified as Vertucci type I. The cross sections were oval in 61% of the canals. Lateral canals were found in 25% of the samples. The main foramen did not coincide with the root apex in 95% of the cases. Only 8% of the canals were classified as straight. Apical constriction was identified in 38% of the roots. The minor and major canal diameters and minor dentin thickness were decreased near the apex. The minor dentin thickness 1 mm from the foramen was 0.82 mm. The palatal canals exhibited a volume of 6.91 mm(3) and surface area of 55.31 mm(2) and were rod-shaped. The root canals of the palatal roots were classified as type I. However, some factors need to be considered during the treatment of these roots, including the frequent ocurrence of moderate/severe curvatures, oval-shaped cross-sections, and lateral canals, noncoincidence of the apical foramen with the root apex, and absence of apical constriction in most cases. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  11. Vena Cava Responsiveness to Controlled Isovolumetric Respiratory Efforts.

    PubMed

    Folino, Anna; Benzo, Marco; Pasquero, Paolo; Laguzzi, Andrea; Mesin, Luca; Messere, Alessandro; Porta, Massimo; Roatta, Silvestro

    2017-10-01

    Respirophasic variation of inferior vena cava (IVC) size is affected by large variability with spontaneous breathing. This study aims at characterizing the dependence of IVC size on controlled changes in intrathoracic pressure. Ten healthy subjects, in supine position, performed controlled isovolumetric respiratory efforts at functional residual capacity, attaining positive (5, 10, and 15 mmHg) and negative (-5, -10, and -15 mmHg) alveolar pressure levels. The isovolumetric constraint implies that equivalent changes are exhibited by alveolar and intrathoracic pressures during respiratory tasks. The IVC cross-sectional area equal to 2.88 ± 0.43 cm 2 at baseline (alveolar pressure = 0 mmHg) was progressively decreased by both expiratory and inspiratory efforts of increasing strength, with diaphragmatic efforts producing larger effects than thoracic ones: -55 ± 15% decrease, at +15 mmHg of alveolar pressure (P < .01), -80 ± 33 ± 12% at -15 mmHg diaphragmatic (P < .01), -33 ± 12% at -15 mmHg thoracic. Significant IVC changes in size (P < .01) and pulsatility (P < .05), along with non significant reduction in the response to respiratory efforts, were also observed during the first 30 minutes of supine rest, detecting an increase in vascular filling, and taking place after switching from the standing to the supine position. This study quantified the dependence of the IVC cross-sectional area on controlled intrathoracic pressure changes and evidenced the stronger influence of diaphragmatic over thoracic activity. Individual variability in thoracic/diaphragmatic respiratory pattern should be considered in the interpretation of the respirophasic modulations of IVC size. © 2017 by the American Institute of Ultrasound in Medicine.

  12. Behaviour of wrapped cold-formed steel columns under different loading conditions

    NASA Astrophysics Data System (ADS)

    Baabu, B. Hari; Sreenath, S.

    2017-07-01

    The use of Cold Formed Steel (CFS) sections as structural members is widely accepted because of its light nature. However, the load carrying capacity of these sections will be less compared to hot rolled sections. This study is meant to analyze the possibility of strengthening cold formed members by wrapping it with Glass Fiber Reinforced Polymer (GFRP) laminates. Light gauge steel columns of cross sectional dimensions 100mm x 50mm x 3.15mm were taken for this study. The effective length of the section is about 750mm. A total of 8 specimens including the control specimen is tested under axial and eccentric loading. The columns were tested keeping both ends hinged. For both loading cases the buckling behaviour, ultimate load carrying capacity and load-deflection characteristics of the CFS columns were analyzed. The GFRP laminates were wrapped on columns in three different ways such that wrapping the outer surface of web and flange throughout the length of specimen, wrapping the outer surface of web alone throughout the length of specimen and wrapping the outer surface of web and flange for the upper half length of the specimen where the buckling is expected. For both loading cases, the results indicated that the column with wrapping at the outer surface of web and flange throughout the length of specimen provides better strength for it.

  13. Occupational Stress and Hypertension among Railway Loco Pilots and Section Controllers.

    PubMed

    Jayakumar, Devasigamoney

    2017-01-01

    A cross-sectional study on occupational stress was conducted on loco pilots in 2008, in view of loco pilots being one of the high strain jobs in Indian Railways. Subsequently, a comparative cross-sectional study on occupational stress was conducted among section controllers in 2011, which is another high strain job of Indian Railways. The studies were conducted to analyze and compare occupational stress and hypertension. A cross-sectional study on occupational stress and hypertension was conducted among 230 loco pilots in 2008, and subsequently, a comparative cross-sectional study was conducted among 82 section controllers in 2011. A closed end 24 item questionnaire on occupational stress was administered. Systolic blood pressure above 140 mmHg and diastolic blood pressure above 90 mmHg were considered as hypertension as per the VII Joint National Committee. Chi-square test and t -test were used for testing significance at P < 0.05. The mean stress score was 8.56 in loco pilots and 7.32 in section controllers. The number of loco pilots with more than 12 stress factors was 49 (21.3%) and the number of section controllers with more than 12 stress factors was 7 (8.5%). The number employees with more than 12 stress factors in different categories of loco pilots were 30 (32%) in the goods category, 12 (12%) in the mail/passenger category, and 7 (19%) in the shunter category, and 3 (11%) in the supervisory category and 4 (7%) in the on-board category of section controllers. The prevalence of hypertension in loco pilots was 36.52% (84) and in the section controllers was 53.66% (44). The prevalence of hypertension in the category with more than 12 stress factors was 30.61% (15) in the loco pilots and 28.57% (2) in the section controllers. The prevalence of hypertension in the both the study groups were higher in the older age, with a family history of hypertension, and with a body mass index of more than 25 kg/m 2 . The mean occupational stress and employees with more than 12 stress factors were higher in the loco pilots group. The goods category of loco pilots had highest stress factors. The prevalence of hypertension was high in the category with risk factors such as older age, family history of hypertension and BMI above 25 kg/m 2 .

  14. Journal of Rehabilitation Research and Development Progress Reports 1994, Volume 32, June 1995

    DTIC Science & Technology

    1995-06-01

    Stepping Over an Obstacle: Effect of Reduced Visual Field 50 Effect of Reduced Optic Flow on Gait 51 Effects of Robotic-Assisted Weight Support on Gait...Geometry in Hip Replacement 240 Wear Debris Generation in Hip Modular Head and Neck Components 241 Changes in Bone Blood Flow Associated with...rectangular cross-section to form a continuously flowing ribbon of melted plastic. Rib- bon dimensions are 0.75 mm thick and 5 mm wide, corresponding to

  15. Early Postoperative Magnetic Resonance Imaging in Detecting Radicular Pain After Lumbar Decompression Surgery: Retrospective Study of the Relationship Between Dural Sac Cross-sectional Area and Postoperative Radicular Pain.

    PubMed

    Futatsugi, Toshimasa; Takahashi, Jun; Oba, Hiroki; Ikegami, Shota; Mogami, Yuji; Shibata, Syunichi; Ohji, Yoshihito; Tanikawa, Hirotaka; Kato, Hiroyuki

    2017-07-01

    A retrospective analysis. To evaluate the association between early postoperative dural sac cross-sectional area (DCSA) and radicular pain. The correlation between postoperative magnetic resonance imaging (MRI) findings and postoperative neurological symptoms after lumbar decompression surgery is controversial. This study included 115 patients who underwent lumbar decompression surgery followed by MRI within 7 days postoperatively. There were 46 patients with early postoperative radicular pain, regardless of whether the pain was mild or similar to that before surgery. The intervertebral level with the smallest DCSA was identified on MRI and compared preoperatively and postoperatively. Risk factors for postoperative radicular pain were determined using univariate and multivariate analyses. Subanalysis according to absence/presence of a residual suction drain also was performed. Multivariate regression analysis showed that smaller postoperative DCSA was significantly associated with early postoperative radicular pain (per -10 mm; odds ratio, 1.26). The best cutoff value for radicular pain was early postoperative DCSA of 67.7 mm. Even with a cutoff value of <70 mm, sensitivity and specificity are 74.3% and 75.0%, respectively. Early postoperative DCSA was significantly larger before suction drain removal than after (119.7±10.1 vs. 93.9±5.4 mm). Smaller DCSA in the early postoperative period was associated with radicular pain after lumbar decompression surgery. The best cutoff value for postoperative radicular pain was 67.7 mm. Absence of a suction drain at the time of early postoperative MRI was related to smaller DCSA.

  16. On the anatomy and histology of the pubovisceral muscle enthesis in women.

    PubMed

    Kim, Jinyong; Ramanah, Rajeev; DeLancey, John O L; Ashton-Miller, James A

    2011-09-01

    The origin of the pubovisceral muscle (PVM) from the pubic bone is known to be at elevated risk for injury during difficult vaginal births. We examined the anatomy and histology of its enthesial origin to classify its type and see if it differs from appendicular entheses. Parasagittal sections of the pubic bone, PVM enthesis, myotendinous junction, and muscle proper were harvested from five female cadavers (51-98 years). Histological sections were prepared with hematoxylin and eosin, Masson's trichrome, and Verhoeff-Van Gieson stains. The type of enthesis was identified according to a published enthesial classification scheme. Quantitative imaging analysis was performed in sampling bands 2 mm apart along the enthesis to determine its cross-sectional area and composition. The PVM enthesis can be classified as a fibrous enthesis. The PVM muscle fibers terminated in collagenous fibers that insert tangentially onto the periosteum of the pubic bone for the most part. Sharpey's fibers were not observed. In a longitudinal cross-section, the area of the connective tissue and muscle becomes equal approximately 8 mm from the pubic bone. The PVM originates bilaterally from the pubic bone via fibrous entheses whose collagen fibers arise tangentially from the periosteum of the pubic bone. Copyright © 2010 Wiley-Liss, Inc.

  17. On the Anatomy and Histology of the Pubovisceral Muscle Enthesis in Women

    PubMed Central

    Kim, Jinyong; Ramanah, Rajeev; DeLancey, John O. L.; Ashton-Miller, James A.

    2012-01-01

    Aims The origin of the pubovisceral muscle (PVM) from the pubic bone is known to be at elevated risk for injury during difficult vaginal births. We examined the anatomy and histology of its enthesial origin to classify its type and see if it differs from appendicular entheses. Methods Parasagittal sections of the pubic bone, PVM enthesis, myotendinous junction and muscle proper were harvested from five female cadavers (51 - 98 years). Histological sections were prepared with hematoxylin and eosin, Masson’s trichrome, and Verhoeff-Van Gieson stains. The type of enthesis was identified according to a published enthesial classification scheme. Quantitative imaging analysis was performed in sampling bands 2 mm apart along the enthesis to determine its cross-sectional area and composition. Results The PVM enthesis can be classified as a fibrous enthesis. The PVM muscle fibers terminated in collagenous fibers that insert tangentially onto the periosteum of the pubic bone for the most part. Sharpey’s fibers were not observed. In a longitudinal cross-section, the area of the connective tissue and muscle becomes equal approximately 8 mm from the pubic bone. Conclusion The PVM originates bilaterally from the pubic bone via fibrous entheses whose collagen fibers arise tangentially from the periosteum of the pubic bone. PMID:21567449

  18. Characterization of linear accelerator X-ray source size using a laminated beam-spot camera.

    PubMed

    Yeboah, Collins

    2011-05-10

    A laminated beam-spot camera of length 20 cm and effective cross-sectional area 2.5 cm × 3 cm was designed and constructed for the measurement of X-ray beam-spot sizes on different models of Siemens accelerators. With the accelerator gantry at 180° and camera positioned on an accessory tray holder, an XV film placed in contact with the camera at the distal end of it detected those X-rays that were transmitted through the camera. The FWHM of the detected X-ray intensity profile in the gun-target (G-T) direction or the orthogonal A-B direction was used as a measure of the beam-spot size in that direction. Siemens Mevatron MXEs exhibited a beam-spot size of 1.7 ± 0.2 mm in both the in-plane and cross-plane directions for 6 MV photon beams. The beam-spot size observed for a Mevatron MDX-2 was larger by up to 1 mm, and also was different for the in-plane and cross-plane directions. For Siemens PRIMUS accelerators, the beam-spot size in the in-plane direction was found to fall in the range 2.0-2.2 ± 0.2 mm, whereas the beam-spot size in the cross-plane direction fell within 1.7-1.9 ± 0.2 mm for 6, 10, and 18 MV photon beams. Assessment of long-term stability of the beam-spot size shows the spot size remains fairly stable over time.

  19. Walleye age estimation using otoliths and dorsal spines: Preparation techniques and sampling guidelines based on sex and total length

    USGS Publications Warehouse

    Dembkowski, Daniel J.; Isermann, Daniel A.; Koenigs, Ryan P.

    2017-01-01

    We used dorsal spines and otoliths from 735 Walleye Sander vitreus collected from 35 Wisconsin water bodies to evaluate whether 1) otolith and dorsal spine cross sections provided age estimates similar to simpler methods of preparation (e.g., whole otoliths and dorsal spines, cracked otoliths); and 2) between-reader precision and differences between spine and otolith ages varied in relation to total length (TL), sex, and growth rate. Ages estimated from structures prepared using simpler techniques were generally similar to ages estimated using thin sections of dorsal spines and otoliths, suggesting that, in some instances, much of the additional processing time and specialized equipment associated with thin sectioning could be avoided. Overall, between-reader precision was higher for sectioned otoliths (mean coefficient of variation [CV] = 3.28%; standard error [SE] = 0.33%) than for sectioned dorsal spines (mean CV = 9.20%; SE = 0.56%). When using sectioned otoliths for age assignment, between-reader precision did not vary between sexes or growth categories (i.e., fast, moderate, slow), but between-reader precision was higher for females than males when using sectioned dorsal spines. Dorsal spines were generally effective at replicating otolith ages for male Walleye <450 mm TL and female Walleye <600 mm TL, suggesting that dorsal spines can be used to estimate ages for male Walleye <450 mm TL and female Walleye <600 mm TL. If sex is unknown, we suggest dorsal spines be used to estimate ages for Walleye <450 mm TL, but that otoliths be used for fish >450 mm TL. Our results provide useful guidance on structure and preparation technique selection for Walleye age estimation, thereby allowing biologists to develop sampling guidelines that could be implemented using information that is always (TL) or often (sex) available at the time of fish collection.

  20. Comparative range of orthodontic wires.

    PubMed

    Ingram, S B; Gipe, D P; Smith, R J

    1986-10-01

    ADA specification No. 32 for determining the range (elastic limit) of orthodontic wires uses the bending of a wire section treated as a cantilever beam. An alternative method for defining the range of orthodontic wires proposed by Waters (1981) is to wrap wire sections around mandrels of varying diameters and measure the deformation imparted after unwrapping. Four brass mandrels with a total of 46 test diameters ranging from 3.5 to 60.0 mm were used in this study. Wire sections 9 cm in length were rolled on the mandrel with a hand lathe. The mandrel cross section required to produce a predetermined amount of deformation (2 mm arc height for a 5 cm chord) was defined as the yield diameter for that particular wire. No individual wire was tested twice so as to avoid introduction of strain history. Test samples of 488 different orthodontic wires supplied by nine commercial distributors were evaluated (a total of 4,747 samples). Stainless steel wires of identical dimensions had a large variation in range, depending on the state of strain hardening and heat treatment. For example, 0.020 inch round wire had yield diameters ranging from 22.8 mm for Australian special plus orange (TP Laboratories) to 42.9 mm for Nubryte gold (G.A.C. International). Chromium cobalt wires had less range than stainless steel before heat treatment, but increased greatly in range after heat treatment. Nitinol (Unitek) had the greatest range of all wires tested (yield diameter of 8.7 mm for 0.016 inch Nitinol). Multistranded stainless steel wires had yield diameters between 9.0 and 14.0 mm.

  1. Development of fast cooling pulsed magnets at the Wuhan National High Magnetic Field Center.

    PubMed

    Peng, Tao; Sun, Quqin; Zhao, Jianlong; Jiang, Fan; Li, Liang; Xu, Qiang; Herlach, Fritz

    2013-12-01

    Pulsed magnets with fast cooling channels have been developed at the Wuhan National High Magnetic Field Center. Between the inner and outer sections of a coil wound with a continuous length of CuNb wire, G10 rods with cross section 4 mm × 5 mm were inserted as spacers around the entire circumference, parallel to the coil axis. The free space between adjacent rods is 6 mm. The liquid nitrogen flows freely in the channels between these rods, and in the direction perpendicular to the rods through grooves provided in the rods. For a typical 60 T pulsed magnetic field with pulse duration of 40 ms, the cooling time between subsequent pulses is reduced from 160 min to 35 min. Subsequently, the same technology was applied to a 50 T magnet with 300 ms pulse duration. The cooling time of this magnet was reduced from 480 min to 65 min.

  2. Ring stability of underground toroidal tanks

    NASA Astrophysics Data System (ADS)

    Lubis, Asnawi; Su'udi, Ahmad

    2017-06-01

    The design of pressure vessels subjected to internal pressure is governed by its strength, while the design of pressure vessels subjected to external pressure is governed by its stability, which is for circular cross-section is called the ring stability. This paper presented the results of finite element study of ring stability of circular toroidal tank without stiffener under external pressure. The tank was placed underground and external pressure load from soil was simulated as pressure at the top of the vessel along 30° circumferentially. One might ask the reason for choosing toroidal rather than cylindrical tank. Preliminary finite element studies showed that toroidal shells can withstand higher external pressure than cylindrical shells. In this study, the volume of the tank was fixed for 15,000 litters. The buckling external pressure (pL) was calculated for radius ratio (R/r) of 2, 3, and 4. The corresponding cross-section radiuses were 724.3 mm, 632.7 mm, and 574.9 mm, respectively. The selected element type was SHELL 281 from the ANSYS element library. To obtain the buckling load, the arc-length method was used in the nonlinear analysis. Both material and geometric nonlinearities were activated during the analysis. The conclusion of this study is that short-radius and thin-walled toroidal shell produces higher buckling load.

  3. The structure of Ti-Ta welded joint and microhardness distribution over the cross section

    NASA Astrophysics Data System (ADS)

    Fomin, Aleksandr A.; Koshuro, Vladimir A.; Egorov, Ivan S.; Shelkunov, Andrey Yu.; Zakharevich, Andrey M.; Steinhauer, Natalia N.; Rodionov, Igor V.

    2018-04-01

    In order to create highly efficient medical systems and measuring biosensors, an approach is frequently used, in which the constructive basis of the product is made of a high-strength biocompatible material (titanium, stainless steel), and the functional layer is made of a more expensive metal (Ta, Zr, Au, Pt, etc.) or ceramics (Ta2O5, ZrO2, CaTiO3, etc.). For a strong connection, e.g. titanium with tantalum, it is proposed to use diffusion butt welding. The heat generated by passing electric current (I is not less than 1.95-2.05 kA, P - not less than 9 kW, t = 250-1000 ms) and applied pressure (30-50 MPa) ensure an integral connection. To improve the quality of the joint, i.e. to exclude cracks and tightness, it is necessary to choose the right combination of the thickness of the welded parts. It was established that when titanium (2 mm thick) and tantalum (0.1-0.5 mm) are combined, a better Ti-Ta welded joint is formed when tantalum foil is used (0.5 mm). Here the distribution of hardness over the cross section of the sample, including the welding areas, is uniform and has no extremely high residual stresses of the tensile type.

  4. Prevalence and predictors for clinical attachment loss in adolescents in Latin America: cross-sectional study.

    PubMed

    Morales, Alicia; Carvajal, Paola; Romanelli, Hugo; Gómez, Mariel; Loha, Cristina; Esper, María E; Musso, Graciela; Ardila, Carlos M; Duque, Andrés; Medina, Marco; Bueno, Luis; Andrade, Ernesto; Mendoza, Carolina; Gamonal, Jorge

    2015-10-01

    To describe the prevalence, severity and extension of clinical attachment loss (CAL) and to study the predictors in 15- to 19-year-old adolescents from high schools in the Latin America. A cross-sectional, epidemiological study was performed. The sample included 1070 high school adolescents 15-19 years of age from Santiago de Chile (Chile), Buenos Aires, Córdoba, Mendoza (Argentina), Montevideo (Uruguay), Quito (Ecuador) and Medellín (Colombia). Calibrated examiners performed full mouth, six sites per tooth clinical examination. There was a response rate of 100%. The prevalence of CAL ≥3 mm in ≥1 site was 32.6%, probing pocket depth ≥4 mm was 59.3% and bleeding on probing (BoP) ≥25% was 28.6%. The logistic regression analysis adjusted for cities revealed that smoking (OR = 1.6), attending public school (OR = 2.3) and having a BoP ≥25% (OR = 4.2) were positively associated with CAL ≥3 mm in ≥ 1 site. Clinical attachment loss was prevalent in Latin America adolescents and it is associated with smoking, attendance public school and BoP. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Achilles Tendon Properties of Minimalist and Traditionally Shod Runners.

    PubMed

    Histen, Katherine; Arntsen, Julia; L'Hereux, Lauren; Heeren, James; Wicki, Benjamin; Saint, Sterling; Aerni, Giselle; Denegar, Craig R; Joseph, Michael F

    2017-04-01

    Tendon adapts to load through alterations in its composition and mechanical properties. Mechanical adaptation to increased load often involves increases in cross-sectional area (CSA), stiffness, and modulus. Runners exhibit these adaptations. To determine if runners wearing minimalist shoes had larger and stiffer Achilles tendons (AT) than traditionally shod runners. Cross-sectional study of well-trained, traditionally and minimally shod runners. Laboratory assessment of trained runners. 23 men (11 traditional, 12 minimalist) and 8 women (6 traditional, 2 minimalist). Runners wearing minimalist shoes had 4.2 ± 1.6 y of training experience in minimalist shoes. The authors used diagnostic ultrasound and isokinetic dynamometry to generate a force-elongation curve and its derivatives. Minimalist runners had a greater CSA: mean difference (MD) = 9.2 mm 2 , stiffness (MD = 268.1 N/mm), and modulus (MD = 202.9 MPa). ATs of minimalist runners experienced greater stress (MD 8.6 N/mm 2 ) during maximal voluntary isometric contraction of the plantar-flexor muscles due to greater force of contraction (MD 798.9 N). The AT in minimalist runners adapts by increasing size, stiffness, and modulus, which is consistent with our understanding of mechanical adaptation of tendon to increased loading. Increased stress to the AT likely requires a slow transition to minimalist running to allow the AT to adapt without evidence of injury.

  6. Model-based cartilage thickness measurement in the submillimeter range

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Streekstra, G. J.; Strackee, S. D.; Maas, M.

    2007-09-15

    Current methods of image-based thickness measurement in thin sheet structures utilize second derivative zero crossings to locate the layer boundaries. It is generally acknowledged that the nonzero width of the point spread function (PSF) limits the accuracy of this measurement procedure. We propose a model-based method that strongly reduces PSF-induced bias by incorporating the PSF into the thickness estimation method. We estimated the bias in thickness measurements in simulated thin sheet images as obtained from second derivative zero crossings. To gain insight into the range of sheet thickness where our method is expected to yield improved results, sheet thickness wasmore » varied between 0.15 and 1.2 mm with an assumed PSF as present in the high-resolution modes of current computed tomography (CT) scanners [full width at half maximum (FWHM) 0.5-0.8 mm]. Our model-based method was evaluated in practice by measuring layer thickness from CT images of a phantom mimicking two parallel cartilage layers in an arthrography procedure. CT arthrography images of cadaver wrists were also evaluated, and thickness estimates were compared to those obtained from high-resolution anatomical sections that served as a reference. The thickness estimates from the simulated images reveal that the method based on second derivative zero crossings shows considerable bias for layers in the submillimeter range. This bias is negligible for sheet thickness larger than 1 mm, where the size of the sheet is more than twice the FWHM of the PSF but can be as large as 0.2 mm for a 0.5 mm sheet. The results of the phantom experiments show that the bias is effectively reduced by our method. The deviations from the true thickness, due to random fluctuations induced by quantum noise in the CT images, are of the order of 3% for a standard wrist imaging protocol. In the wrist the submillimeter thickness estimates from the CT arthrography images correspond within 10% to those estimated from the anatomical sections. We present a method that yields virtually unbiased thickness estimates of cartilage layers in the submillimeter range. The good agreement of thickness estimates from CT images with estimates from anatomical sections is promising for clinical application of the method in cartilage integrity staging of the wrist and the ankle.« less

  7. 3D Measurement of Anatomical Cross-sections of Foot while Walking

    NASA Astrophysics Data System (ADS)

    Kimura, Makoto; Mochimaru, Masaaki; Kanade, Takeo

    Recently, techniques for measuring and modeling of human body are taking attention, because human models are useful for ergonomic design in manufacturing. We aim to measure accurate shape of human foot that will be useful for the design of shoes. For such purpose, shape measurement of foot in motion is obviously important, because foot shape in the shoe is deformed while walking or running. In this paper, we propose a method to measure anatomical cross-sections of foot while walking. No one had ever measured dynamic shape of anatomical cross-sections, though they are very basic and popular in the field of biomechanics. Our proposed method is based on multi-view stereo method. The target cross-sections are painted in individual colors (red, green, yellow and blue), and the proposed method utilizes the characteristic of target shape in the camera captured images. Several nonlinear conditions are introduced in the process to find the consistent correspondence in all images. Our desired accuracy is less than 1mm error, which is similar to the existing 3D scanners for static foot measurement. In our experiments, the proposed method achieved the desired accuracy.

  8. Convection and macrosegregation in Al-19Cu alloy directionally solidified through an abrupt contraction in cross-section: A comparison with Al-7Si

    NASA Astrophysics Data System (ADS)

    Ghods, M.; Lauer, M.; Grugel, R. N.; Tewari, S. N.; Poirier, D. R.

    2017-02-01

    Hypoeutectic Al-19 wt. % Cu alloys were directionally solidified in cylindrical molds that featured an abrupt cross-section decrease 9.5 to 3.2 mm in diameter). Thermo-solutal convection and cross-section-change-induced shrinkage flow effects on macrosegregation were investigated. Dendrite clustering and extensive radial macrosegregation was seen, particularly in the larger cross-section before contraction. This alloy shows positive longitudinal macrosegregation near the contraction followed by negative macrosegregation right after it; the extent of macrosegregation, however, decreases with increasing growth speed. The degree of thermo-solutal convection was compared to another study investigating directional solidification of Al-7 wt. % Si [1] in order to study the effect of solutal expansion coefficient on macrosegregation. An interesting change of the radial macrosegregation profile, attributable to the area-change-induced-shrinkage flow, was observed very close to the contraction. A two-dimensional model accounting for both shrinkage and thermo-solutal convection was used to simulate solidification, the resulting steepling as well as axial and radial macrosegregation. The experimentally observed macrosegregation associated with the contraction during directional solidification was well predicted by the numerical simulations.

  9. Socioeconomic factors and severity of periodontal disease in adults (35-44 years). A cross sectional study

    PubMed Central

    Almerich-Silla, José-Manuel; Almiñana-Pastor, Pedro J.; Boronat-Catalá, Montserrat; Montiel-Company, José-María

    2017-01-01

    Background Periodontal disease or periodontitis is an inflammatory disease with a hight prevalence. According to the last oral health survey of the Spanish population, between 24% and 37% of Spaniards aged over 35 years have periodontitis and 6% to 10% of the adult population have deep periodontal pockets. The aim of this study was to determine the association between risk factors and the presence of periodontal pockets in the adult population. Material and Methods A cross sectional or prevalence study of a representative sample of the adult population of the Valencia region was designed. The sample was recruited at 35 health centres, The study was conducted in November and December 2006 under standardized conditions as regards light sources, equipment and instruments and the position of the three previously calibrated dentist examiners. Results The sample examined consisted of 733 individuals (220 men and 513 women). Measured by the CPI, 13% were healthy and 5.5% presented bleeding. The prevalence of calculus was 59.3%, that of 3.5-5.5 mm pockets was 15.8% and that of pockets deeper than 5.5 mm was 4.6%. Almost half the sextants were healthy (2.89), 0.61 presented bleeding and 1.74 presented calculus. The mean number of sextants affected by 3.5-5.5 mm pockets was 0.46 and 0.07 presented deep pockets (>5.5 mm). An adjusted multiple logistic regression model with the presence of periodontal pockets as the dependent variable showed that the significant independent variables were low social class (OR=1.81), smoking (OR=1.68), primary education (OR=1.57), male gender (OR=1.56) and age (OR=1.08). The other study variables were not significant in this model. Conclusions Socioeconomic factors such as primary education and low social class, as well as gender, age and smoking, were found to be associated to a significant degree with greater prevalence of periodontal disease in the adult population. Key words:Periodontal disease, adults, socioeconomic factors, periodontal pockets, cross sectional study. PMID:28936289

  10. [Surgical peculiarities of gunshot injuries to arteries of the extremities caused by modern small arms and light weapons].

    PubMed

    Samokhvalov, I M; Reva, V A; Denisov, A V; Ozeretskovskiĭ, L B; Pronchenko, A A

    2014-10-01

    The aim of the given study was development of surgical tactics in case of femoral artery injury, caused by medium-calibre bullet, on the basis acute experiment on large biological objects. Experimental animals were shot into mid third of the femora by a rifle cartridge in 7,62-mm calibre (AK-47 made in 1943). The analysis of microstructure, made in 5 cross-sections performed every 1-centimetre way from the wound canal, showed that there were no any damages of arterial wall. Authors came to conclusion that the surgical debridement of the gunshot wound, made by a rifle cartridge in 7,62-mm calibre of AK-47, should consist of exsection of devitalized section of artery.

  11. Which cardiovascular magnetic resonance planes and sequences provide accurate measurements of branch pulmonary artery size in children with right ventricular outflow tract obstruction?

    PubMed

    Vijarnsorn, Chodchanok; Rutledge, Jennifer M; Tham, Edythe B; Coe, James Y; Quinonez, Luis; Patton, David J; Noga, Michelle

    2014-02-01

    Children with right ventricular outflow tract obstructive (RVOTO) lesions require precise quantification of pulmonary artery (PA) size for proper management of branch PA stenosis. We aimed to determine which cardiovascular magnetic resonance (CMR) sequences and planes correlated best with cardiac catheterization and surgical measurements of branch PA size. Fifty-five children with RVOTO lesions and biventricular circulation underwent CMR prior to; either cardiac catheterization (n = 30) or surgery (n = 25) within a 6 month time frame. CMR sequences included axial black blood, axial, coronal oblique and sagittal oblique cine balanced steady-state free precession (bSSFP), and contrast-enhanced magnetic resonance angiography (MRA) with multiplanar reformatting in axial, coronal oblique, sagittal oblique, and cross-sectional planes. Maximal branch PA and stenosis (if present) diameter were measured. Comparisons of PA size on CMR were made to reference methods: (1) catheterization measurements performed in the anteroposterior plane at maximal expansion, and (2) surgical measurement obtained from a maximal diameter sound which could pass through the lumen. The mean differences (Δ) and intra class correlation (ICC) were used to determine agreement between different modalities. CMR branch PA measurements were compared to the corresponding cardiac catheterization measurements in 30 children (7.6 ± 5.6 years). Reformatted MRA showed better agreement for branch PA measurement (ICC > 0.8) than black blood (ICC 0.4-0.6) and cine sequences (ICC 0.6-0.8). Coronal oblique MRA and maximal cross sectional MRA provided the best correlation of right PA (RPA) size with ICC of 0.9 (Δ -0.1 ± 2.1 mm and Δ 0.5 ± 2.1 mm). Maximal cross sectional MRA and sagittal oblique MRA provided the best correlate of left PA (LPA) size (Δ 0.1 ± 2.4 and Δ -0.7 ± 2.4 mm). For stenoses, the best correlations were from coronal oblique MRA of right pulmonary artery (RPA) (Δ -0.2 ± 0.8 mm, ICC 0.9) and sagittal oblique MRA of left pulmonary artery (LPA) (Δ 0.2 ± 1.1 mm, ICC 0.9). CMR PA measurements were compared to surgical measurements in 25 children (5.4 ± 4.8 years). All MRI sequences demonstrated good agreement (ICC > 0.8) with the best (ICC 0.9) from axial cine bSSFP for both RPA and LPA. Maximal cross sectional and angulated oblique reformatted MRA provide the best correlation to catheterization for measurement of branch PA's and stenosis diameter. This is likely due to similar angiographic methods based on reformatting techniques that transect the central axis of the arteries. Axial cine bSSFP CMR was the best surgically measured correlate of PA branch size due to this being a measure of stretched diameter. Knowledge of these differences provides more precise PA measurements and may aid catheter or surgical interventions for RVOTO lesions.

  12. Thermal neutron cross-section and resonance integral of the 152Sm(n,γ)153Sm reaction induced by pulsed neutrons

    NASA Astrophysics Data System (ADS)

    Van Do, Nguyen; Khue, Pham Duc; Thanh, Kim Tien; Hien, Nguyen Thi; Kim, Guinyun; Kim, Kwangsoo; Shin, Sung-Gyun; Kye, Yong-Uk; Cho, Moo-Hyun

    2017-10-01

    We measured the thermal neutron cross-section (σ0) and resonance integral (I0) of the 152Sm(n,γ)153Sm reaction relative to that of the 197Au(n,γ)198Au reaction. Sm and Au foils with and without a cadmium cover of 0.5 mm were irradiated with moderated pulsed neutrons produced from the electron linac. The induced activities of the reaction products were determined via high energy resolution HPGe detector. The present results: σ0,Sm =212±8 b and I0,Sm =3.02±0.19 kb are consistent with most of the existing reference data.

  13. Radiographic considerations for the regional anatomy in the posterior mandible.

    PubMed

    Yashar, Natasha; Engeland, Christopher G; Rosenfeld, Alan L; Walsh, Timothy P; Califano, Joseph V

    2012-01-01

    Previous studies of the inferior alveolar nerve have used cadaveric specimens in small patient groups. The purpose of this study was to describe the anatomy in the posterior mandible with respect to the inferior alveolar nerve (IAN) using computed tomography (CT) images in a large patient population. We hypothesize that CT scans are an important component of a thorough treatment plan for minimizing risk to the IAN and optimizing surgical outcomes. CT scans of 195 patients (62 males and 133 females; age range: 22 to 88 years) were evaluated retrospectively. With the aid of computer software, cross-sectional images were examined at 5-mm increments distal to the mental foramen to the ascending ramus. Four measurements were made at each cross-sectional image. The distances from the IAN to the: 1) alveolar crest (CN); 2) buccal cortical plate (BN); 3) lingual cortical plate (LN); and 4) inferior border (IN) were measured. Most measurements for males and females were significantly different. Mean values were as follows (males/females): CN, 13.85 ± 0.43/11.98 ± 0.40 mm (P <0.01); BN, 4.98 ± 0.15/4.47 ± 0.11 mm (P <0.01); LN, 2.93 ± 0.12/3.19 ± 0.10 mm (P <0.10); and IN, 7.76 ± 0.16/7.00 ± 0.15 mm (P <0.01). The 95% confidence intervals indicated that many patients had limited bone volume in the buccal shelf or ascending ramus. Given the high degree of variability in mandibular bone volume surrounding the IAN and the position of the IAN, the use of CT scans should be considered for surgical procedures in the posterior mandible when there is risk of injury to the IAN.

  14. Subject-Specific Finite Element Analysis of the Carpal Tunnel Cross-Sectional to Examine Tunnel Area Changes in Response to Carpal Arch Loading

    PubMed Central

    Walia, Piyush; Erdemir, Ahmet; Li, Zong-Ming

    2017-01-01

    Background Manipulating the carpal arch width (i.e. distance between hamate and trapezium bones) has been suggested as a means to increase carpal tunnel cross-sectional area and alleviate median nerve compression. The purpose of this study was to develop a finite element model of the carpal tunnel and to determine an optimal force direction to maximize area. Methods A planar geometric model of carpal bones at hamate level was reconstructed from MRI with inter-carpal joint spaces filled with a linear elastic surrogate tissue. Experimental data with discrete carpal tunnel pressures (50, 100, 150, and 200 mmHg) and corresponding carpal bone movements were used to obtain material property of surrogate tissue by inverse finite element analysis. The resulting model was used to simulate changes of carpal arch widths and areas with directional variations of a unit force applied at the hook of hamate. Findings Inverse finite element model predicted the experimental area data within 1.5% error. Simulation of force applications showed that carpal arch width and area were dependent on the direction of force application, and minimal arch width and maximal area occurred at 138° (i.e. volar-radial direction) with respect to the hamate-to-trapezium axis. At this force direction, the width changed to 24.4 mm from its initial 25.1 mm (3% decrease), and the area changed to 301.6 mm2 from 290.3 mm2 (4% increase). Interpretation The findings of the current study guide biomechanical manipulation to gain tunnel area increase, potentially helping reduce carpal tunnel pressure and relieve symptoms of compression median neuropathy. PMID:28073093

  15. The Construction and Calibration of a LADAR (Laser Detection and Ranging) Cross-Section Measurement Range

    DTIC Science & Technology

    1985-12-01

    resonator optics consist of two porro prisms which are oriented 900 from one another about the cavity’s optical axis. In other words, the roof edges of each... prism are perpendicular to one another. The Nd:YAG laser rod measures 5 mm in diameter by 75 mm long and is optically pumped by a Xenon flashlamp. Q...Switching of the laser is performed by a Pockels Cell. A dielectric polarizer is sealed between two right angle prisms which are joined symetrically

  16. Evaluation of isthmus prevalence, location, and types in mesial roots of mandibular molars in the Iranian Population

    PubMed Central

    Mehrvarzfar, Payman; Akhlagi, Nahid Mohammadzade; Khodaei, Fatemeh; Shojaee, Golnaz; Shirazi, Sara

    2014-01-01

    Background: Management of canal isthmus is considered as an important factor for successful endodontic treatment. Accordingly, this study was designed to determine the prevalence, location, and types of isthmus in mesial root canals of extracted mandibular molars in a sample of Iranian population. Materials and Methods: In this cross-sectional descriptive study, 60 extracted molars with two mesial canals were included. The samples were initially decoronated and then, roots were sectioned horizontally at 2, 4, and 6 mm levels from the apex via a low-speed handpiece with a thin metallic disk and finally prepared and stained with Indian ink. All sections were examined using a stereomicroscope at a magnification of ×30. Prevalence, location, and types of isthmus were evaluated based on the classifications by Kim and Teixeira and all data were statistically analyzed by the chi-squared test. The statistical significance level was established at 0.05. Results: Eighty-three percent of extracted mandibular molars had an isthmus at the mesial root. This prevalence increased with distance from the apex, that is, 92% at 6 mm from the apex and 70% at 2 mm from the apex. A statistically significant difference was found between the sections at 2 and 6 mm from the apex (P < 0.05), but no other significant differences between other levels (P > 0.05). Conclusion: Isthmus is very common in the mesial roots of the mandibular permanent molars in the Iranian population, with the highest prevalence in the 6 mm distance from the root apex. Therefore, detection, cleaning, and filling of these apical 6 mm isthmuses are of great benefit in modern endodontics. PMID:24932198

  17. Why Do Silver Trimers Intercalated in DNA Exhibit Unique Nonlinear Properties That Are Promising for Applications?

    PubMed

    Bonačić-Koutecký, Vlasta; Perić, Martina; Sanader, Željka

    2018-05-17

    Our investigation of one-photon absorption (OPA) and nonlinear optical (NLO) properties such as two-photon absorption (TPA) of silver trimer intercalated in DNA based on TDDFT approach allowed us to propose a mechanism responsible for large TPA cross sections of such NLO-phores. We present a concept that illustrates the key role of quantum cluster as well as of nucleotide bases from the immediate neighborhood. For this purpose, different surroundings consisting of guanine-cytosine and adenine-thymine such as (GCGC) and (ATAT) have been investigated that are exhibiting substantially different values of TPA cross sections. This has been confirmed by extending the immediate surroundings as well as using the two-layer quantum mechanics/molecular mechanics (QM/MM) approach. We focus on the cationic closed-shell system and illustrate that the neutral open-shell system shifts OPA spectra into the NIR regime, which is suitable for applications. Thus, in this contribution, we propose novel NLO-phores inducing large TPA cross sections, opening the route for multiphoton imaging.

  18. A 100,000 Scale Factor Radar Range.

    PubMed

    Blanche, Pierre-Alexandre; Neifeld, Mark; Peyghambarian, Nasser

    2017-12-19

    The radar cross section of an object is an important electromagnetic property that is often measured in anechoic chambers. However, for very large and complex structures such as ships or sea and land clutters, this common approach is not practical. The use of computer simulations is also not viable since it would take many years of computational time to model and predict the radar characteristics of such large objects. We have now devised a new scaling technique to overcome these difficulties, and make accurate measurements of the radar cross section of large items. In this article we demonstrate that by reducing the scale of the model by a factor 100,000, and using near infrared wavelength, the radar cross section can be determined in a tabletop setup. The accuracy of the method is compared to simulations, and an example of measurement is provided on a 1 mm highly detailed model of a ship. The advantages of this scaling approach is its versatility, and the possibility to perform fast, convenient, and inexpensive measurements.

  19. Cross-sectional imaging of extracted jawbone of a pig by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Tachikawa, Noriko; Yoshimura, Reiko; Ohbayashi, Kohji

    2011-03-01

    Dental implantation has become popular in dental treatments. Although careful planning is made to identify vital structures such as the inferior alveolar nerve or the sinus, as well as dimensions of the bone, prior to commencement of surgery, dental implantation is not fully free from risks. If a diagnostic tool is available to objectively measure bone feature before surgery and dimensions during surgery, considerable fraction of the risks may be avoided. Optical coherence tomography (OCT) is a candidate for the purpose, which enables cross-sectional imaging of bone. In this work, we performed in vitro cross-sectional imaging of extracted pig's jawbone with swept source OCT using superstructure-grating distributed Bragg reflector (SSG-DBR) laser as the source. The relatively long wavelength range of 1600nm of the laser is suitable for deeper bone imaging. We confirmed an image penetration depth of about 3 mm in physical length, which satisfies one of the criterions to apply OCT for in vivo diagnosis of bone during surgery.

  20. Time-resolved flowmetering of gas-liquid two-phase pipe flow by ultrasound pulse Doppler method

    NASA Astrophysics Data System (ADS)

    Murai, Yuichi; Tasaka, Yuji; Takeda, Yasushi

    2012-03-01

    Ultrasound pulse Doppler method is applied for componential volumetric flow rate measurement in multiphase pipe flow consisted of gas and liquid phases. The flowmetering is realized with integration of measured velocity profile over the cross section of the pipe within liquid phase. Spatio-temporal position of interface is detected also with the same ultrasound pulse, which further gives cross sectional void fraction. A series of experimental demonstration was shown by applying this principle of measurement to air-water two-phase flow in a horizontal tube of 40 mm in diameter, of which void fraction ranges from 0 to 90% at superficial velocity from 0 to 15 m/s. The measurement accuracy is verified with a volumetric type flowmeter. We also analyze the accuracy of area integration of liquid velocity distribution for many different patterns of ultrasound measurement lines assigned on the cross section of the tube. The present method is also identified to be pulsation sensor of flow rate that fluctuates with complex gas-liquid interface behavior.

  1. Measurements of the thermal neutron cross-section and resonance integral for the 108Pd(n,γ)109Pd reaction

    NASA Astrophysics Data System (ADS)

    Hien, Nguyen Thi; Kim, Guinyun; Kim, Kwangsoo; Do, Nguyen Van; Khue, Pham Duc; Thanh, Kim Tien; Shin, Sung-Gyun; Cho, Moo-Hyun

    2018-06-01

    The thermal neutron capture cross-section (σ0) and resonance integral (I0) of the 108Pd(n,γ)109Pd reaction have been measured relative to that of the monitor reaction 197Au(n,γ)198Au. The measurements were carried out using the neutron activation with the cadmium ratio method. Both the samples and monitors were irradiated with and without cadmium cover of 0.5 mm thickness. The induced activities of the reaction products were measured with a well calibrated HPGe γ-ray detector. In order to improve the accuracy of the results, the necessary corrections for the counting losses were made. The thermal neutron capture cross-section and resonance integral of the 108Pd(n,γ)109Pd reaction were determined to be σ0,Pd = 8.68 ± 0.41 barn and I0,Pd = 245.6 ± 24.8 barn, respectively. The obtained results are compared with literature values and discussed.

  2. Experimental examination of ultraviolet Raman cross sections of chemical warfare agent simulants

    NASA Astrophysics Data System (ADS)

    Kullander, F.; Landström, L.; Lundén, H.; Wästerby, Pär.

    2015-05-01

    Laser induced Raman scattering from the commonly used chemical warfare agent simulants dimethyl sulfoxide, tributyl phosphate, triethyl phosphonoacetate was measured at excitation wavelengths ranging from 210 to 410 nm using a pulsed laser based spectrometer system with a probing distance of 1.4 m and with a field of view on the target of less than 1mm. For the purpose of comparison with well explored reference liquids the Raman scattering from simulants was measured in the form of an extended liquid surface layer on top of a silicon wafer. This way of measuring enabled direct comparison to the Raman scattering strength from cyclohexane. The reference Raman spectra were used to validate the signal strength of the simulants and the calibration of the experimental set up. Measured UV absorbance functions were used to calculate Raman cross sections. Established Raman cross sections of the simulants make it possible to use them as reference samples when measuring on chemical warfare agents in droplet form.

  3. 75 FR 81968 - Circular Welded Carbon Quality Steel Pipe From the People's Republic of China: Rescission of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-29

    ... and its individual members, Allied Tube & Conduit, IPSCO Tubulars, Inc., Sharon Tube Company, Western Tube & Conduit Corporation, and Wheatland Tube Company (collectively, ``Petitioner''), that the... pipes and tubes, of circular cross-section, and with an outside diameter of 0.372 inches (9.45 mm) or...

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Malashin, M. V.; Moshkunkov, S. I.; Khomich, V. Yu.

    The spatiotemporal dynamics of a nanosecond atmospheric-pressure dielectric barrier discharge in 1- to 3-mm-long air gaps was studied experimentally. By using a segmented electrode, data on the time evolution of the discharge in different regions of the discharge gap were obtained. The uniformity of the discharge over the cross section is estimated by analyzing the spatial distribution of its glow.

  5. Quantification of human upper extremity nerves and fascicular anatomy.

    PubMed

    Brill, Natalie A; Tyler, Dustin J

    2017-09-01

    In this study we provide detailed quantification of upper extremity nerve and fascicular anatomy. The purpose is to provide values and trends in neural features useful for clinical applications and neural interface device design. Nerve cross-sections were taken from 4 ulnar, 4 median, and 3 radial nerves from 5 arms of 3 human cadavers. Quantified nerve features included cross-sectional area, minor diameter, and major diameter. Fascicular features analyzed included count, perimeter, area, and position. Mean fascicular diameters were 0.57 ± 0.39, 0.6 ± 0.3, 0.5 ± 0.26 mm in the upper arm and 0.38 ± 0.18, 0.47 ± 0.18, 0.4 ± 0.27 mm in the forearm of ulnar, median, and radial nerves, respectively. Mean fascicular diameters were inversely proportional to fascicle count. Detailed quantitative anatomy of upper extremity nerves is a resource for design of neural electrodes, guidance in extraneural procedures, and improved neurosurgical planning. Muscle Nerve 56: 463-471, 2017. © 2016 Wiley Periodicals, Inc.

  6. Radiation and scattering from bodies of translation, volume 1

    NASA Astrophysics Data System (ADS)

    Medgyesi-Mitschang, L. N.

    1980-04-01

    An analytical formulation, based on the method of moments (MM) is described for solving electromagnetic problems associated with finite-length cylinders of arbitrary cross section, denoted in this report as bodies of translation (BOT). This class of bodies can be used to model structures with noncircular cross sections such as wings, fins, and aircraft fuselages. The theoretical development parallels in part the MM formulation developed earlier by Mautz and Harrington for bodies of revolution (BOR). Like the latter approach, a modal expansion is used to describe the unknown surface currents on the BOT. The present analysis has been developed to treat the far-field radiation and scattering from a BOT excited by active antennas or illuminated by a plane wave of arbitrary polarization and angle of incidence. In addition, the electric and magnetic near-field components are determined in the vicinity of active and passive apertures (slots). Using the Schelkunoff equivalence theorem, the aperture-coupled fields within a BOT are also obtained. The formulation has been implemented by a computer algorithm and validated using accepted data in the literature.

  7. Association of dental infections with systemic diseases in Brazilian Native Indigenous: a cross-sectional study.

    PubMed

    Ribeiro, Lívia S F; Santos, Jean N; Vieira, Carolina L Z; Caramelli, Bruno; Ramalho, Luciana M P; Cury, Patricia R

    2016-05-01

    The aim of this cross-sectional study was to evaluate the association between dental infections and systemic diseases in the Indigenous population of Brazil. A representative sample of 225 Indigenous (≥19 years) was assessed. The T-test and bivariate and logistic models were used to assess the associations of diabetes, hypertension, and obesity with dental caries and destructive periodontal disease. After adjustments for covariates, dental caries were associated with hypertension (odds ratio = 1.95; 95% confidence interval: 1.03-3.66; P = .04). Individuals with destructive periodontal disease had a higher systolic blood pressure (124 ± 20.34 mm Hg) than those without destructive periodontal disease (117.52 ± 16.54 mm Hg; P = .01). In conclusion, dental infections were found to be associated with hypertension in the present population. Thus, patients diagnosed with hypertension should be referred for dental evaluation and vice versa. Copyright © 2016 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  8. Measurement of the Absolute Raman Cross Sections of Diethyl Phthalate, Dimethyl Phthalate, Ethyl Cinnamate, Propylene Carbonate, Tripropyl Phosphate, 1,3-Cyclohexanedione, 3’-Aminoacetophenone, 3’-Hydroxyacetophenone, Diethyl Acetamidomalonate, Isovanillin, Lactide, Meldrum’s Acid, p-Tolyl Sulfoxide, and Vanillin

    DTIC Science & Technology

    2013-09-13

    Germany/Buena Park, California). The HWP is Edmund Optics part number 46-561 (Edmund Optics, Barrington, New Jersey). The BS is Semrock part number...LPD01-785RS-25×36×1.1 with 803– 1214 nm passband ( Semrock , Rochester, New York). The lens L1 is a 12-mm-diameter, 20-mm-effective- focal-length (EFL...near-infrared (NIR) achromat Edmund Optics part number 45-792. The long-wave- pass filters are 25-mm-diameter Semrock part number LP02-785RE-25 with

  9. Occupational Stress and Hypertension among Railway Loco Pilots and Section Controllers

    PubMed Central

    Jayakumar, Devasigamoney

    2017-01-01

    Introduction: A cross-sectional study on occupational stress was conducted on loco pilots in 2008, in view of loco pilots being one of the high strain jobs in Indian Railways. Subsequently, a comparative cross-sectional study on occupational stress was conducted among section controllers in 2011, which is another high strain job of Indian Railways. Objective: The studies were conducted to analyze and compare occupational stress and hypertension. Setting and Design: A cross-sectional study on occupational stress and hypertension was conducted among 230 loco pilots in 2008, and subsequently, a comparative cross-sectional study was conducted among 82 section controllers in 2011. Materials and Methods: A closed end 24 item questionnaire on occupational stress was administered. Systolic blood pressure above 140 mmHg and diastolic blood pressure above 90 mmHg were considered as hypertension as per the VII Joint National Committee. Chi-square test and t-test were used for testing significance at P < 0.05. Results: The mean stress score was 8.56 in loco pilots and 7.32 in section controllers. The number of loco pilots with more than 12 stress factors was 49 (21.3%) and the number of section controllers with more than 12 stress factors was 7 (8.5%). The number employees with more than 12 stress factors in different categories of loco pilots were 30 (32%) in the goods category, 12 (12%) in the mail/passenger category, and 7 (19%) in the shunter category, and 3 (11%) in the supervisory category and 4 (7%) in the on-board category of section controllers. The prevalence of hypertension in loco pilots was 36.52% (84) and in the section controllers was 53.66% (44). The prevalence of hypertension in the category with more than 12 stress factors was 30.61% (15) in the loco pilots and 28.57% (2) in the section controllers. The prevalence of hypertension in the both the study groups were higher in the older age, with a family history of hypertension, and with a body mass index of more than 25 kg/m2. The mean occupational stress and employees with more than 12 stress factors were higher in the loco pilots group. The goods category of loco pilots had highest stress factors. The prevalence of hypertension was high in the category with risk factors such as older age, family history of hypertension and BMI above 25 kg/m2. PMID:29391744

  10. P-S & S-P Elastic Wave Conversions from Linear Arrays of Oriented Microcracks

    NASA Astrophysics Data System (ADS)

    Jiang, L.; Modiriasari, A.; Bobet, A.; Pyrak-Nolte, L. J.

    2017-12-01

    Natural and induced processes can produce oriented mechanical discontinuities such as en echelon cracks, fractures and faults. Previous research has shown that compressional to shear (P-S) wave conversions occur at normal incidence to a fracture because of cross-coupling fracture compliances (Nakagawa et al., 2000). Here, experiments and computer simulation are presented to demonstrate the link among cross-coupling stiffness, microcrack orientation and energy partitioning among P, S, and P-S/S-P waves. A FormLabs 2 3D printer was used to fabricate 7 samples (50 mm x 50 mm x 100 mm) with linear arrays of microcracks oriented at 0, 15, 30, 45, 60, 75, and 900 with a print resolution of 0.025 mm. The microcracks were elliptical in cross-sections (2 mm long by 1 mm wide), through the 50 mm thickness of sample, and spaced 3 mm (center-to-center for adjacent cracks). A 25 mm length of each sample contained no microcracks to act as a reference material. Broadband transducers (0.2-1.5 MHz) were used to transmit and receive P and polarized S wave signals that were propagated at normal incidence to the linear array of microcracks. P-wave amplitude increased, while S-wave amplitude remained relatively constant, as the microcrack orientation increased from 0o to 90o. At normal incidence, P-S and S-P wave conversions emerged and increased in amplitude as the crack inclination increased from 00 to 450. From 450 to 900, the amplitude of these converted modes decreased. Between negative and positive crack angles, the P-to-S and S-to-P waves were 1800 phase reversed. The observed energy partitioning matched the computed compliances obtained from numerical simulations with ABAQUS. The cross-coupling compliance for cracks inclined at 450 was found to be the smallest magnitude. 3D printing enabled the study of microstructural effects on macro-scale wave measurements. Information on the orientation of microcracks or even en echelon fractures and faults is contained in P-S conversions even at normal incidence. Acknowledgment: This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, Geosciences Research Program under Award Number (DE-FG02-09ER16022) and by the National Science Foundation, Geomechanics and Geotechnical Systems Program (award No. CMMI-1162082).

  11. INTERNAL REPAIR OF PIPELINES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robin Gordon; Bill Bruce; Ian Harris

    2004-04-12

    The two broad categories of deposited weld metal repair and fiber-reinforced composite liner repair technologies were reviewed for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Preliminary test programs were developed for both deposited weld metal repair and for fiber-reinforced composite liner repair. Evaluation trials have been conducted using a modified fiber-reinforced composite liner provided by RolaTube and pipe sections without liners. All pipe section specimens failed in areas of simulated damage. Pipe sections containing fiber-reinforcedmore » composite liners failed at pressures marginally greater than the pipe sections without liners. The next step is to evaluate a liner material with a modulus of elasticity approximately 95% of the modulus of elasticity for steel. Preliminary welding parameters were developed for deposited weld metal repair in preparation of the receipt of Pacific Gas & Electric's internal pipeline welding repair system (that was designed specifically for 559 mm (22 in.) diameter pipe) and the receipt of 559 mm (22 in.) pipe sections from Panhandle Eastern. The next steps are to transfer welding parameters to the PG&E system and to pressure test repaired pipe sections to failure. A survey of pipeline operators was conducted to better understand the needs and performance requirements of the natural gas transmission industry regarding internal repair. Completed surveys contained the following principal conclusions: (1) Use of internal weld repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling (HDD) when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) Pipe diameter sizes range from 50.8 mm (2 in.) through 1,219.2 mm (48 in.). The most common size range for 80% to 90% of operators surveyed is 508 mm to 762 mm (20 in. to 30 in.), with 95% using 558.8 mm (22 in.) pipe. An evaluation of potential repair methods clearly indicates that the project should continue to focus on the development of a repair process involving the use of GMAW welding and on the development of a repair process involving the use of fiber-reinforced composite liners.« less

  12. Safety and protection of 8T NbTi gyrotron magnet in persistent mode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Usak, P.; Kokavec, J.; Chovanec, F.

    1993-09-01

    Successful series of 5T cryomagnetic systems for additional high frequency plasma heating in Tokamaks T10 and T15, produced in Czechoslovakia during the last decade with the authors participation in magnet design and testing encouraged them to continue in further development of gyrotron magnets for further generation with operational field B[sub 0] = 8T. Approximately of the size and dimensions as was the case of previous 5T series, the 8T gyrotron magnet was designed as a part of preliminary work with preparations for ITER project. To achieve high mechanical stability of the superconducting winding, numerical stress-strain analyzes of winding structure andmore » appropriate technology of epoxy impregnation were applied. To improve winding mechanical stability, initially round [phi]1 mm varnish insulated conductor was flattened to race track'' cross section (1.25 [times] 0.75 mm[sup 2] for inner section, respectively, 1.31 [times] 0.65 mm[sup 2] for the rest of magnet). Stainless steel road ([phi]1mm) of the bandage was flattened in the same way too (up to 1.14 [times] 0.77 mm[sup 2]). Danger of creating a hot spot region has been limited by radial magnet sectioning and sections shunting by low ohmic shunts. Superconducting switch was protected by couple of antiparallel silicon diodes mounted between magnet flanges in parallel to it. High threshold voltages of diodes at 4.2K allow to run up system with relatively high speed without any limitation on sign of magnet field polarity.« less

  13. Comparative evaluation of physicians' pulmonary nodule detection with reduced slice thickness at CT screening

    NASA Astrophysics Data System (ADS)

    Sinsuat, Marodina; Shimamura, Ichiro; Saita, Shinsuke; Kubo, Mitsuru; Kawata, Yoshiki; Niki, Noboru; Ohmatsu, Hironobu; Kakinuma, Ryutaro; Eguchi, Kenji; Kaneko, Masahiro; Tominaga, Keigo; Moriyama, Noriyuki

    2008-03-01

    With thin and thick section Multi-slice CT images at lung cancer screening, we have statistically and quantitatively shown and evaluated the diagnostic capabilities of these slice thicknesses on physicians' pulmonary nodule diagnosis. To comparatively evaluate the 2 mm and 10 mm slice thicknesses, MSCT images of 360 people were read by six physicians. The reading criteria consisted of nodule for further examination (NFE), nodule for no further examination (NNFE) and no abnormality (NA) case. For reading results evaluation; firstly, cross-tabulation was carried out to roughly analyze the diagnoses based on whole lung field and each lung lobes. Secondly, from semi-automated extraction result of the nodule, detailed quantitative analysis was carried out to determine the diagnostic capabilities of two slice thicknesses. Finally, using the reading results of 2 mm thick image as the gold standard, the diagnostic capabilities were analyzed through the features and locations of pulmonary nodules. The study revealed that both slice thicknesses can depict lung cancer. Thin section may not be effective to diagnose nodules of <=3 mm in size and nodules of <= 5mm in size for thick section. Though thick section is less tiring for reading physicians, it is not good at depicting nodules located at the border of lung upper lobe and which have a pixel size distance of <=5 from the chest wall. The information presented may serve as a useful reference to determine in which particular pulmonary nodule condition the two slice thicknesses can be effectively used for early detection of lung cancer.

  14. Morphological Features and Important Parameters of Large Optic Discs for Diagnosing Glaucoma

    PubMed Central

    Okimoto, Satoshi; Yamashita, Keiko; Shibata, Tetsuo; Kiuchi, Yoshiaki

    2015-01-01

    Purpose To compare the optic disc parameters of glaucomatous eyes to those of non-glaucomatous eyes with large discs. Methods We studied 225 consecutive eyes with large optic discs (>2.82 mm2): 91 eyes with glaucoma and 134 eyes without glaucoma. An eye was diagnosed with glaucoma when visual field defects were detected by the Humphrey Field Analyzer. All of the Heidelberg Retina Tomograph II (HRT II) parameters were compared between the non-glaucomatous and glaucomatous eyes. A logistic regression analysis of the HRT II parameters was used to establish a new formula for diagnosing glaucoma, and the sensitivity and specificity of the Moorfields Regression Analysis (MRA) was compared to the findings made by our analyses. Results The mean disc area was 3.44±0.50 mm2 in the non-glaucomatous group and 3.40±0.52 mm2 in the glaucoma group. The cup area, cup volume, cup-to-disc area ratio, linear cup/disc ratio, mean cup depth, and the maximum cup depth were significantly larger in glaucomatous eyes than in the non-glaucomatous eyes. The rim area, rim volume, cup shape measurement, mean retinal nerve fiber layer (RNFL) thickness, and RFNL cross-sectional area were significantly smaller in glaucomatous eyes than in non-glaucomatous eyes. The cup-to-disc area ratio, the height variation contour (HVC), and the RNFL cross-sectional area were important parameters for diagnosing the early stage glaucoma, and the cup-to-disc area ratio and cup volume were useful for diagnosing advanced stage glaucoma in eyes with a large optic disc. The new formula had higher sensitivity and specificity for diagnosing glaucoma than MRA. Conclusions The cup-to-disc area ratio, HVC, RNFL cross-sectional area, and cup volume were important parameters for diagnosing glaucoma in eyes with a large optic disc. The important disc parameters to diagnose glaucoma depend on the stage of glaucoma in patients with large discs. PMID:25798580

  15. Effects of spine loading in a patient with post-decompression lumbar disc herniation: observations using an open weight-bearing MRI.

    PubMed

    Mahato, Niladri Kumar; Sybert, Daryl; Law, Tim; Clark, Brian

    2017-05-01

    Our objective was to use an open weight-bearing MRI to identify the effects of different loading conditions on the inter-vertebral anatomy of the lumbar spine in a post-discectomy recurrent lumbar disc herniation patient. A 43-year-old male with a left-sided L5-S1 post-decompression re-herniation underwent MR imaging in three spine-loading conditions: (1) supine, (2) weight-bearing on standing (WB), and (3) WB with 10 % of body mass axial loading (WB + AL) (5 % through each shoulder). A segmentation-based proprietary software was used to calculate and compare linear dimensions, angles and cross sections across the lumbar spine. The L5 vertebrae showed a 4.6 mm posterior shift at L5-S1 in the supine position that changed to an anterior translation >2.0 mm on WB. The spinal canal sagittal thickness at L5-S1 reduced from supine to WB and WB + AL (13.4, 10.6, 9.5 mm) with corresponding increases of 2.4 and 3.5 mm in the L5-S1 disc protrusion with WB and WB + AL, respectively. Change from supine to WB and WB + AL altered the L5-S1 disc heights (10.2, 8.6, 7.0 mm), left L5-S1 foramen heights (12.9, 11.8, 10.9 mm), L5-S1 segmental angles (10.3°, 2.8°, 4.3°), sacral angles (38.5°, 38.3°, 40.3°), L1-L3-L5 angles (161.4°, 157.1°, 155.1°), and the dural sac cross sectional areas (149, 130, 131 mm 2 ). Notably, the adjacent L4-L5 segment demonstrated a retro-listhesis >2.3 mm on WB. We observed that with weight-bearing, measurements indicative of spinal canal narrowing could be detected. These findings suggest that further research is warranted to determine the potential utility of weight-bearing MRI in clinical decision-making.

  16. Macrosegregation Resulting from Directional Solidification Through an Abrupt Change in Cross-Sections

    NASA Technical Reports Server (NTRS)

    Lauer, M.; Poirier, D. R.; Ghods, M.; Tewari, S. N.; Grugel, R. N.

    2017-01-01

    Simulations of the directional solidification of two hypoeutectic alloys (Al-7Si alloy and Al-19Cu) and resulting macrosegregation patterns are presented. The casting geometries include abrupt changes in cross-section from a larger width of 9.5 mm to a narrower 3.2 mm width then through an expansion back to a width of 9.5 mm. The alloys were chosen as model alloys because they have similar solidification shrinkages, but the effect of Cu on changing the density of the liquid alloy is about an order of magnitude greater than that of Si. The simulations compare well with experimental castings that were directionally solidified in a graphite mold in a Bridgman furnace. In addition to the simulations of the directional solidification in graphite molds, some simulations were effected for solidification in an alumina mold. This study showed that the mold must be included in numerical simulations of directional solidification because of its effect on the temperature field and solidification. For the model alloys used for the study, the simulations clearly show the interaction of the convection field with the solidifying alloys to produce a macrosegregation pattern known as "steepling" in sections with a uniform width. Details of the complex convection- and segregation-patterns at both the contraction and expansion of the cross-sectional area are revealed by the computer simulations. The convection and solidification through the expansions suggest a possible mechanism for the formation of stray grains. The computer simulations and the experimental castings have been part of on-going ground-based research with the goal of providing necessary background for eventual experiments aboard the ISS. For casting practitioners, the results of the simulations demonstrate that computer simulations should be applied to reveal interactions between alloy solidification properties, solidification conditions, and mold geometries on macrosegregation. The simulations also presents the possibility of engineering the mold-material to avoid, or mitigate, the effects of thermosolutal convection and macrosegregation by selecting a mold material with suitable thermal properties, especially its thermal conductivity.

  17. Analysis of Femoral Components of Cemented Total Hip Arthroplasty

    NASA Astrophysics Data System (ADS)

    Singh, Shantanu; Harsha, A. P.

    2016-10-01

    There have been continuous on-going revisions in design of prosthesis in Total Hip Arthroplasty (THA) to improve the endurance of hip replacement. In the present work, Finite Element Analysis was performed on cemented THA with CoCrMo trapezoidal, CoCrMo circular, Ti6Al4V trapezoidal and Ti6Al4V circular stem. It was observed that cross section and material of femoral stem proved to be critical parameters for stress distribution in femoral components, distribution of interfacial stress and micro movements. In the first part of analysis, designs were investigated for micro movements and stress developed, for different stem materials. Later part of the analysis focused on investigations with respect to different stem cross sections. Femoral stem made of Titanium alloy (Ti6Al4V) resulted in larger debonding of stem at cement-stem interface and increased stress within the cement mantle in contrast to chromium alloy (CoCrMo) stem. Thus, CoCrMo proved to be a better choice for cemented THA. Comparison between CoCrMo femoral stem of trapezium and circular cross section showed that trapezoidal stem experiences lesser sliding and debonding at interfaces than circular cross section stem. Also, trapezium cross section generated lower peak stress in femoral stem and cortical femur. In present study, femur head with diameter of 36 mm was considered for the analysis in order to avoid dislocation of the stem. Also, metallic femur head was coupled with cross linked polyethylene liner as it experiences negligible wear compared to conventional polyethylene liner and unlike metallic liner it is non carcinogenic.

  18. Automatic evaluation of the Valsalva sinuses from cine-MRI

    NASA Astrophysics Data System (ADS)

    Blanchard, Cédric; Sliwa, Tadeusz; Lalande, Alain; Mohan, Pauliah; Bouchot, Olivier; Voisin, Yvon

    2011-03-01

    MRI appears to be particularly attractive for the study of the Sinuses of Valsalva (SV), however there is no global consensus on their suitable measurements. In this paper, we propose a new method, based on the mathematical morphology and combining a numerical geodesic reconstruction with an area estimation, to automatically evaluate the SV from a cine-MRI in a cross-sectional orientation. It consists in the extraction of the shape of the SV, the detection of relevant points (commissures, cusps and the centre of the SV), the measurement of relevant distances and in a classification of the valve as bicuspid or tricuspid by a metric evaluation of the SV. Our method was tested on 23 patient examinations and radii calculations were compared with a manual measurement. The classification of the valve as tricuspid or bicuspid was correct for all the cases. Moreover, there are an excellent correlation and an excellent concordance between manual and automatic measurements for images at diastolic phase (r= 0.97; y = x - 0.02; p=NS; mean of differences = -0.1 mm; standard deviation of differences = 2.3 mm) and at systolic phase (r= 0.96; y = 0.97 x + 0.80; p=NS ; mean of differences = -0.1 mm; standard deviation of differences = 2.4 mm). The cross-sectional orientation of the image acquisition plane conjugated with our automatic method provides a reliable morphometric evaluation of the SV, based on the automatic location of the centre of the SV, the commissure and the cusp positions. Measurements of distances between relevant points allow a precise evaluation of the SV.

  19. Facet joint hypertrophy is a misnomer: A retrospective study.

    PubMed

    An, Sang Joon; Seo, Mi Sook; Choi, Soo Il; Lim, Tae-Ha; Shin, So Jin; Kang, Keum Nae; Kim, Young Uk

    2018-06-01

    One of the major causes of lumbar spinal canal stenosis (LSCS) has been considered facet joint hypertrophy (FJH). However, a previous study asserted that "FJH" is a misnomer because common facet joints are no smaller than degenerative facet joints; however, this hypothesis has not been effectively demonstrated. Therefore, in order to verify that FJH is a misnomer in patients with LSCS, we devised new morphological parameters that we called facet joint thickness (FJT) and facet joint cross-sectional area (FJA).We collected FJT and FJA data from 114 patients with LSCS. A total of 86 control subjects underwent lumbar magnetic resonance imaging (MRI) as part of routine medical examinations, and axial T2-weighted MRI images were obtained from all participants. We measured FJT by drawing a line along the facet area and then measuring the narrowest point at L4-L5. We measured FJA as the whole cross-sectional area of the facet joint at the stenotic L4-L5 level.The average FJT was 1.60 ± 0.36 mm in the control group and 1.11 ± 0.32 mm in the LSCS group. The average FJA was 14.46 ± 5.17 mm in the control group and 9.31 ± 3.47 mm in the LSCS group. Patients with LSCS had significantly lower FJTs (P < .001) and FJAs (P < .001).FJH, a misnomer, should be renamed facet joint area narrowing. Using this terminology would eliminate confusion in descriptions of the facet joint.

  20. Association between hypertension and chronic arsenic exposure in drinking water: a cross-sectional study in Bangladesh.

    PubMed

    Islam, Mohammad Rafiqul; Khan, Ismail; Attia, John; Hassan, Sheikh Mohammad Nazmul; McEvoy, Mark; D'Este, Catherine; Azim, Syed; Akhter, Ayesha; Akter, Shahnaz; Shahidullah, Sheikh Mohammad; Milton, Abul Hasnat

    2012-12-07

    Chronic arsenic exposure and its association with hypertension in adults are inconclusive and this cross-sectional study investigated the association. The study was conducted between January and July 2009 among 1,004 participants from 1,682 eligible women and men aged ≥30 years living in rural Bangladesh who had continuously consumed arsenic-contaminated drinking water for at least 6 months. Hypertension was defined as systolic blood pressure ≥140 mmHg (systolic hypertension) and diastolic blood pressure ≥90 mmHg (diastolic hypertension). Pulse pressure was calculated by deducting diastolic from systolic pressure and considered to be increased when the difference was ≥55 mmHg. The prevalence of hypertension was 6.6% (95% CI: 5.1-8.3%). After adjustment for other factors, no excess risk of hypertension was observed for arsenic exposure >50 μg/L or to that of arsenic exposure as quartiles or as duration. Arsenic concentration as quartiles and >50 μg/L did show a strong relationship with increased pulse pressure (adjusted OR: 3.54, 95% CI: 1.46-8.57), as did arsenic exposure for ≥10 years (adjusted OR: 5.25, 95% CI: 1.41-19.51). Arsenic as quartiles showed a dose response relationship with increased pulse pressure. Our study suggests an association between higher drinking water arsenic or duration and pulse pressure, but not hypertension.

  1. Search for R -parity violating supersymmetry with displaced vertices in proton-proton collisions at s = 8 TeV

    DOE PAGES

    Khachatryan, V.; Sirunyan, A. M.; Tumasyan, A.; ...

    2017-01-25

    Results are reported from a search for R-parity violating supersymmetry in proton-proton collision events collected by the CMS experiment at a center-of-mass energy of √s = 8 TeV. Here, the data sample corresponds to an integrated luminosity of 17.6 fb –1. This search assumes a minimal flavor violating model in which the lightest supersymmetric particle is a long-lived neutralino or gluino, leading to a signal with jets emanating from displaced vertices. In a sample of events with two displaced vertices, no excess yield above the expectation from standard model processes is observed, and limits are placed on the pair productionmore » cross section as a function of mass and lifetime of the neutralino or gluino. At 95% confidence level, the analysis excludes cross sections above approximately 1 fb for neutralinos or gluinos with mass between 400 and 1500 GeV and mean proper decay length between 1 and 30 mm. Gluino masses are excluded below 1 and 1.3 TeV for mean proper decay lengths of 300 μm an 1 mm, respectively, and below 1.4 TeV for the range 2–30 mm. The results are also applicable to other models in which long-lived particles decay into multijet final states.« less

  2. Association between Hypertension and Chronic Arsenic Exposure in Drinking Water: A Cross-Sectional Study in Bangladesh

    PubMed Central

    Islam, Mohammad Rafiqul; Khan, Ismail; Attia, John; Hassan, Sheikh Mohammad Nazmul; McEvoy, Mark; D’Este, Catherine; Azim, Syed; Akhter, Ayesha; Akter, Shahnaz; Shahidullah, Sheikh Mohammad; Milton, Abul Hasnat

    2012-01-01

    Chronic arsenic exposure and its association with hypertension in adults are inconclusive and this cross-sectional study investigated the association. The study was conducted between January and July 2009 among 1,004 participants from 1,682 eligible women and men aged ≥30 years living in rural Bangladesh who had continuously consumed arsenic-contaminated drinking water for at least 6 months. Hypertension was defined as systolic blood pressure ≥140 mmHg (systolic hypertension) and diastolic blood pressure ≥90 mmHg (diastolic hypertension). Pulse pressure was calculated by deducting diastolic from systolic pressure and considered to be increased when the difference was ≥55 mmHg. The prevalence of hypertension was 6.6% (95% CI: 5.1–8.3%). After adjustment for other factors, no excess risk of hypertension was observed for arsenic exposure >50μg/L or to that of arsenic exposure as quartiles or as duration. Arsenic concentration as quartiles and >50 μg/L did show a strong relationship with increased pulse pressure (adjusted OR: 3.54, 95% CI: 1.46–8.57), as did arsenic exposure for ≥10 years (adjusted OR: 5.25, 95% CI: 1.41–19.51). Arsenic as quartiles showed a dose response relationship with increased pulse pressure. Our study suggests an association between higher drinking water arsenic or duration and pulse pressure, but not hypertension. PMID:23222207

  3. Search for R -parity violating supersymmetry with displaced vertices in proton-proton collisions at s = 8 TeV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khachatryan, V.; Sirunyan, A. M.; Tumasyan, A.

    Results are reported from a search for R-parity violating supersymmetry in proton-proton collision events collected by the CMS experiment at a center-of-mass energy of √s = 8 TeV. Here, the data sample corresponds to an integrated luminosity of 17.6 fb –1. This search assumes a minimal flavor violating model in which the lightest supersymmetric particle is a long-lived neutralino or gluino, leading to a signal with jets emanating from displaced vertices. In a sample of events with two displaced vertices, no excess yield above the expectation from standard model processes is observed, and limits are placed on the pair productionmore » cross section as a function of mass and lifetime of the neutralino or gluino. At 95% confidence level, the analysis excludes cross sections above approximately 1 fb for neutralinos or gluinos with mass between 400 and 1500 GeV and mean proper decay length between 1 and 30 mm. Gluino masses are excluded below 1 and 1.3 TeV for mean proper decay lengths of 300 μm an 1 mm, respectively, and below 1.4 TeV for the range 2–30 mm. The results are also applicable to other models in which long-lived particles decay into multijet final states.« less

  4. X-Ray Computed Tomography Monitors Damage in Composites

    NASA Technical Reports Server (NTRS)

    Baaklini, George Y.

    1997-01-01

    The NASA Lewis Research Center recently codeveloped a state-of-the-art x-ray CT facility (designated SMS SMARTSCAN model 100-112 CITA by Scientific Measurement Systems, Inc., Austin, Texas). This multipurpose, modularized, digital x-ray facility includes an imaging system for digital radiography, CT, and computed laminography. The system consists of a 160-kV microfocus x-ray source, a solid-state charge-coupled device (CCD) area detector, a five-axis object-positioning subassembly, and a Sun SPARCstation-based computer system that controls data acquisition and image processing. The x-ray source provides a beam spot size down to 3 microns. The area detector system consists of a 50- by 50- by 3-mm-thick terbium-doped glass fiber-optic scintillation screen, a right-angle mirror, and a scientific-grade, digital CCD camera with a resolution of 1000 by 1018 pixels and 10-bit digitization at ambient cooling. The digital output is recorded with a high-speed, 16-bit frame grabber that allows data to be binned. The detector can be configured to provide a small field-of-view, approximately 45 by 45 mm in cross section, or a larger field-of-view, approximately 60 by 60 mm in cross section. Whenever the highest spatial resolution is desired, the small field-of-view is used, and for larger samples with some reduction in spatial resolution, the larger field-of-view is used.

  5. The associations between indices of patellofemoral geometry and knee pain and patella cartilage volume: a cross-sectional study

    PubMed Central

    2010-01-01

    Background Whilst patellofemoral pain is one of the most common musculoskeletal disorders presenting to orthopaedic clinics, sports clinics, and general practices, factors contributing to its development in the absence of a defined arthropathy, such as osteoarthritis (OA), are unclear. The aim of this cross-sectional study was to describe the relationships between parameters of patellofemoral geometry (patella inclination, sulcus angle and patella height) and knee pain and patella cartilage volume. Methods 240 community-based adults aged 25-60 years were recruited to take part in a study of obesity and musculoskeletal health. Magnetic resonance imaging (MRI) of the dominant knee was used to determine the lateral condyle-patella angle, sulcus angle, and Insall-Salvati ratio, as well as patella cartilage and bone volumes. Pain was assessed by the Western Ontario and McMaster University Osteoarthritis Index (WOMAC) VA pain subscale. Results Increased lateral condyle-patella angle (increased medial patella inclination) was associated with a reduction in WOMAC pain score (Regression coefficient -1.57, 95% CI -3.05, -0.09) and increased medial patella cartilage volume (Regression coefficient 51.38 mm3, 95% CI 1.68, 101.08 mm3). Higher riding patella as indicated by increased Insall-Salvati ratio was associated with decreased medial patella cartilage volume (Regression coefficient -3187 mm3, 95% CI -5510, -864 mm3). There was a trend for increased lateral patella cartilage volume associated with increased (shallower) sulcus angle (Regression coefficient 43.27 mm3, 95% CI -2.43, 88.98 mm3). Conclusion These results suggest both symptomatic and structural benefits associated with a more medially inclined patella while a high-riding patella may be detrimental to patella cartilage. This provides additional theoretical support for the current use of corrective strategies for patella malalignment that are aimed at medial patella translation, although longitudinal studies will be needed to further substantiate this. PMID:20459700

  6. Quantifying shape changes of silicone breast implants in a murine model using in vivo micro-CT.

    PubMed

    Anderson, Emily E; Perilli, Egon; Carati, Colin J; Reynolds, Karen J

    2017-08-01

    A major complication of silicone breast implants is the formation of a capsule around the implant known as capsular contracture which results in the distortion of the implant. Recently, a mouse model for studying capsular contracture was examined using micro-computed tomography (micro-CT), however, only qualitative changes were reported. The aim of this study was to develop a quantitative method for comparing the shape changes of silicone implants using in vivo micro-CT. Mice were bilaterally implanted with silicone implants and underwent ionizing radiation to induce capsular contracture. On day 28 post-surgery mice were examined in vivo using micro-CT. The reconstructed cross-section images were visually inspected to identify distortion. Measurements were taken in 2D and 3D to quantify the shape of the implants in the normal (n = 11) and distorted (n = 5) groups. The degree of anisotropy was significantly higher in the distorted implants in the transaxial view (0.99 vs. 1.19, p = 0.002) and the y-axis lengths were significantly shorter in the sagittal (9.27 mm vs. 8.55 mm, p = 0.015) and coronal (9.24 mm vs. 8.76 mm, p = 0.031) views, indicating a deviation from the circular cross-section and shortening of the long axis. The 3D analysis revealed a significantly lower average thickness (sphere-fitting method) in distorted implants (6.86 mm vs. 5.49 mm, p = 0.002), whereas the volume and surface area did not show significant changes. Statistically significant differences between normal and distorted implants were found in 2D and 3D using distance measurements performed via micro-CT. This objective analysis method can be useful for a range of studies involving deformable implants using in vivo micro-CT. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1447-1452, 2017. © 2016 Wiley Periodicals, Inc.

  7. Association of Processed Meat Intake with Hypertension Risk in Hemodialysis Patients: A Cross-Sectional Study

    PubMed Central

    Wu, Pei-Yu; Yang, Shwu-Huey; Wong, Te-Chih; Chen, Tzen-Wen; Chen, His-Hsien; Chen, Tso-Hsiao; Chen, Yu-Tong

    2015-01-01

    In this cross-sectional study, we hypothesized that hemodialysis patients consuming greater processed meat is associated with hypertension risk, which can be partly explained by the high sodium content in processed meat. From September 2013 to May 2014, one hundred and four patients requiring chronic hemodialysis treatment were recruited from hemodialysis centers. Data on systolic blood pressure and diastolic blood pressure before receiving dialysis, and 3-day dietary records of the recruited patients were collected. HD patients with systolic and diastolic blood pressures greater than140 mmHg and higher than 90 mmHg, respectively, were considered hypertension risk. Protein foods were divided into 4 categories: red meat, white meat, soybeans, and processed meat (e.g., sausage and ham). In a model adjusted for energy intake and hypertension history, additional servings of processed meats was positively associated to systolic blood pressure >140 mmHg (odds ratio [95% confidence interval]: 2.1 [1.0–4.3]), and diastolic blood pressure > 90 mmHg (odds ratio: 2.5 [1.2–5.5]). After adjustment for dietary sodium contents or body mass index (BMI), most associations were substantially attenuated and were no longer significant. In systolic blood pressure greater than140 mmHg, one serving per day of red meats (β = -1.22, P < .05) and white meats (β = -0. 75, P = .05) was associated with a reduced risk compared with one serving per day of processed meats. Similarly, compared with one serving per day of processed meat, a reduced risk of diastolic blood pressure higher than 90 mmHg was associated with one serving per day of red meat (β = -1. 59, P < .05), white meat (β = -0. 62, P < .05). Thus, in these hemodialysis patients, intake of processed meat is significantly positively associated with higher blood pressure risk, and both sodium contents in processed meat and BMI significantly contributes to this association. PMID:26517837

  8. The associations between indices of patellofemoral geometry and knee pain and patella cartilage volume: a cross-sectional study.

    PubMed

    Tanamas, Stephanie K; Teichtahl, Andrew J; Wluka, Anita E; Wang, Yuanyuan; Davies-Tuck, Miranda; Urquhart, Donna M; Jones, Graeme; Cicuttini, Flavia M

    2010-05-10

    Whilst patellofemoral pain is one of the most common musculoskeletal disorders presenting to orthopaedic clinics, sports clinics, and general practices, factors contributing to its development in the absence of a defined arthropathy, such as osteoarthritis (OA), are unclear.The aim of this cross-sectional study was to describe the relationships between parameters of patellofemoral geometry (patella inclination, sulcus angle and patella height) and knee pain and patella cartilage volume. 240 community-based adults aged 25-60 years were recruited to take part in a study of obesity and musculoskeletal health. Magnetic resonance imaging (MRI) of the dominant knee was used to determine the lateral condyle-patella angle, sulcus angle, and Insall-Salvati ratio, as well as patella cartilage and bone volumes. Pain was assessed by the Western Ontario and McMaster University Osteoarthritis Index (WOMAC) VA pain subscale. Increased lateral condyle-patella angle (increased medial patella inclination) was associated with a reduction in WOMAC pain score (Regression coefficient -1.57, 95% CI -3.05, -0.09) and increased medial patella cartilage volume (Regression coefficient 51.38 mm3, 95% CI 1.68, 101.08 mm3). Higher riding patella as indicated by increased Insall-Salvati ratio was associated with decreased medial patella cartilage volume (Regression coefficient -3187 mm3, 95% CI -5510, -864 mm3). There was a trend for increased lateral patella cartilage volume associated with increased (shallower) sulcus angle (Regression coefficient 43.27 mm3, 95% CI -2.43, 88.98 mm3). These results suggest both symptomatic and structural benefits associated with a more medially inclined patella while a high-riding patella may be detrimental to patella cartilage. This provides additional theoretical support for the current use of corrective strategies for patella malalignment that are aimed at medial patella translation, although longitudinal studies will be needed to further substantiate this.

  9. Microtensile bond strength of composite resin to human enamel prepared using erbium: Yttrium aluminum garnet laser.

    PubMed

    Delfino, Carina Sinclér; Souza-Zaroni, Wanessa Christine; Corona, Silmara Aparecida Milori; Palma-Dibb, Regina Guenka

    2007-02-01

    The Erbium: Yttrium Aluminum Garnet (YAG) laser used for preparation of cavity can alter the substrate and it could influence the bond strength of enamel. The aim of this in vitro study was to evaluate the influence of Er:YAG laser's energy using microtensile bond test. Three groups were obtained (cavity preparation) and each group was divided into two subgroups (adhesive system). After that the adhesive protocol was performed, sections with a cross-sectional area of 0.8 mm2 (+/-0.2 mm2) were obtained. The specimens were mounted in a universal testing machine (0.5 mm/min). Statistical analysis showed a decrease in bond strength for lased groups (p < 0.01) and when the total-etching adhesive system was used the laser 300 mJ subgroup showed higher bond strength compared to the laser 250 mJ (p < 0.01). It was concluded that the cavities prepared using laser appear less receptive to adhesive procedures than conventional bur-cut cavities. Copyright 2006 Wiley Periodicals, Inc.

  10. Evaluation of the Sendai and 2012 International Consensus Guidelines based on cross-sectional imaging findings performed for the initial triage of mucinous cystic lesions of the pancreas: a single institution experience with 114 surgically treated patients.

    PubMed

    Goh, Brian K P; Thng, Choon-Hua; Tan, Damien M Y; Low, Albert S C; Wong, Jen-San; Cheow, Peng-Chung; Chow, Pierce K H; Chung, Alexander Y F; Wong, Wai-Keong; Ooi, London L P J

    2014-08-01

    The Sendai Consensus Guidelines (SCG) were formulated in 2006 to guide the management of mucinous cystic lesions of the pancreas (CLPs) and were updated in 2012 (International Consensus Guidelines, ICG 2012). This study aims to evaluate the clinical utility of the ICG 2012 with the SCG based on initial cross-sectional imaging findings. One hundred fourteen patients with mucinous CLPs were reviewed and classified according to the ICG 2012 as high risk (HR(ICG2012)), worrisome (W(ICG2012)), and low risk (LR(ICG2012)), and according to the SCG as high risk (HR(SCG)) and low risk (LR(SCG)). On univariate analysis, the presence of symptoms, obstructive jaundice, elevated serum carcinoembryonic antigen (CEA)/carbohydrate antigen (CA)19-9, solid component, main pancreatic duct ≥ 10 mm, and main pancreatic duct ≥ 5 mm was associated with high grade dysplasia/invasive carcinoma in all mucinous CLPs. Increasing number of HR(SCG) or HR(ICG2012) features was associated with a significantly increased likelihood of malignancy. The positive predictive value of HR(SCG) and HR(ICG2012) for high grade dysplasia/invasive carcinoma was 46% and 62.5% respectively. The negative predictive value of both LR(SCG) and LR(ICG2012) was 100%. Both the guidelines were useful in the initial cross-sectional imaging evaluation of mucinous CLPs. The ICG 2012 guidelines were superior to the SCG guidelines. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Dual-high-frequency ultrasound excitation on microbubble destruction volume.

    PubMed

    Shen, Che-Chou; Su, Shin-Yuan; Cheng, Chih-Hao; Yeh, Chih-Kuang

    2010-06-01

    The goal of this work was to test experimentally that exposing air bubbles or ultrasound contrast agents in water to amplitude modulated wave allows control of inertial cavitation affected volume and hence could limit the undesirable bioeffects. Focused transducer operating at the center frequency of 10 MHz and having about 65% fractional bandwidth was excited by 3 micros 8.5 and 11.5 MHz tone-bursts to produce 3 MHz envelope signal. The 3 MHz frequency was selected because it corresponds to the resonance frequency of the microbubbles used in the experiment. Another 5 MHz transducer was used as a receiver to produce B-mode image. Peak negative acoustic pressure was adjusted in the range from 0.5 to 3.5 MPa. The spectrum amplitudes obtained from the imaging of SonoVue contrast agent when using the envelope and a separate 3 MHz transducer were compared to determine their cross-section at the -6 dB level. The conventional 3 MHz tone-burst excitation resulted in the region of interest (ROI) cross-section of 2.47 mm while amplitude modulated, dual-frequency excitation with difference frequency of 3 MHz produced cross-section equal to 1.2mm. These results corroborate our hypothesis that, in addition to the considerably higher penetration depth of dual-frequency excitation due to the lower attenuation at 3 MHz than that at 8.5 and 11.5 MHz, the sample volume of dual-frequency excitation is also smaller than that of linear 3-MHz method for more spatially confined destruction of microbubbles. 2010 Elsevier B.V. All rights reserved.

  12. Atmospheric imaging results from the Mars exploration rovers: Spirit and Opportunity.

    PubMed

    Lemmon, M T; Wolff, M J; Smith, M D; Clancy, R T; Banfield, D; Landis, G A; Ghosh, A; Smith, P H; Spanovich, N; Whitney, B; Whelley, P; Greeley, R; Thompson, S; Bell, J F; Squyres, S W

    2004-12-03

    A visible atmospheric optical depth of 0.9 was measured by the Spirit rover at Gusev crater and by the Opportunity rover at Meridiani Planum. Optical depth decreased by about 0.6 to 0.7% per sol through both 90-sol primary missions. The vertical distribution of atmospheric dust at Gusev crater was consistent with uniform mixing, with a measured scale height of 11.56 +/- 0.62 kilometers. The dust's cross section weighted mean radius was 1.47 +/- 0.21 micrometers (mm) at Gusev and 1.52 +/- 0.18 mm at Meridiani. Comparison of visible optical depths with 9-mm optical depths shows a visible-to-infrared optical depth ratio of 2.0 +/- 0.2 for comparison with previous monitoring of infrared optical depths.

  13. Spatial patterns of erosion in a bedrock gorge

    NASA Astrophysics Data System (ADS)

    Beer, Alexander. R.; Turowski, Jens M.; Kirchner, James W.

    2017-01-01

    Understanding the physical processes driving bedrock channel formation is essential for interpreting and predicting the evolution of mountain landscapes. Here we analyze bedrock erosion patterns measured at unprecedented spatial resolution (mm) over 2 years in a natural bedrock gorge. These spatial patterns show that local bedrock erosion rates depend on position in the channel cross section, height above the streambed, and orientation relative to the main streamflow and sediment path. These observations are consistent with the expected spatial distribution of impacting particles (the tools effect) and shielding by sediment on the bed (the cover effect). Vertical incision by bedrock abrasion averaged 1.5 mm/a, lateral abrasion averaged 0.4 mm/a, and downstream directed abrasion of flow obstacles averaged 2.6 mm/a. However, a single plucking event locally exceeded these rates by orders of magnitude (˜100 mm/a), and accounted for one third of the eroded volume in the studied gorge section over the 2 year study period. Hence, if plucking is spatially more frequent than we observed in this study period, it may contribute substantially to long-term erosion rates, even in the relatively massive bedrock at our study site. Our observations demonstrate the importance of bedrock channel morphology and the spatial distribution of moving and static sediment in determining local erosion rates.

  14. A breath test for malignant mesothelioma using an electronic nose.

    PubMed

    Chapman, Eleanor A; Thomas, Paul S; Stone, Emily; Lewis, Craig; Yates, Deborah H

    2012-08-01

    Malignant mesothelioma (MM) is a rare tumour which is difficult to diagnose in its early stages. Earlier detection of MM could potentially improve survival. Exhaled breath sampling of volatile organic compounds (VOCs) using a carbon polymer array (CPA) electronic nose recognises specific breath profiles characteristic of different diseases, and can distinguish between patients with lung cancer and controls. With MM, the potential confounding effect of other asbestos-related diseases (ARDs) needs to be considered. We hypothesised that as CPA electronic nose would distinguish patients with MM, patients with benign ARDs, and controls with high sensitivity and specificity. 20 MM, 18 ARD and 42 control subjects participated in a cross-sectional, case-control study. Breath samples were analysed using the Cyranose 320 (Smiths Detection, Pasadena, CA, USA), using canonical discriminant analysis and principal component reduction. 10 MM subjects created the training set. Smell prints from 10 new MM patients were distinguished from control subjects with an accuracy of 95%. Patients with MM, ARDs and control subjects were correctly identified in 88% of cases. Exhaled breath VOC profiling can accurately distinguish between patients with MM, ARDs and controls using a CPA electronic nose. This could eventually translate into a screening tool for high-risk populations.

  15. Value of transperineal ultrasound on the observation of paravaginal support.

    PubMed

    Dou, Chaoran; Li, Qin; Ying, Tao; Shui, Wen; Yan, Yulin; Luo, Yijia; Wang, Xia

    2018-04-01

    To explore the feasibility of three-dimensional (3D) transperineal ultrasound on the observation of paravaginal support in nulliparous and postpartum women. Volume datasets were acquired in 50 nulliparous and 100 postpartum women using 3D transperineal ultrasound. Paravaginal supports were observed by studying the vaginal cross-sectional morphology. The extent of paravaginal support in specific level were evaluated by counting out at a 2 mm interval in tomographic ultrasound imaging mode in all subjects. The Mann-Whitney U test were applied to establish comparisons between the two groups. Three representative manifestations of vaginal cross-sectional morphology corresponding to different paravaginal support were presented from the dorsal side to the caudal side, both in nulliparous women and postpartum women. The extent of paravaginal support in middle vagina was 11 slices (range 9-12) in nulliparous women and 7 slices (range 4-10) in postpartum women (P < 0.05). This pilot study confirmed that it was feasible to indirectly study paravaginal support by observing the vaginal cross-sectional morphology using 3D transperineal ultrasound.

  16. Differential cross sections and spin density matrix elements for gamma p -> phi p from CLAS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biplab Dey, Curtis A. Meyer

    2011-10-01

    Preliminary differential cross-sections and the {rho}{sub MM'}{sup 0} spin density matrix elements (SDME) for the reaction {gamma}p {yields} {phi} for both charged- ({phi} {yields} K{sup +}K{sup -}) and neutral-mode ({phi} {yields} K{sub L}{sup 0}K{sub S}{sup 0}) topologies obtained from CLAS are presented. Our kinematic coverage is from near production threshold ({radical}s {approx} 1.97more » $$ GeV) to {radical}s = 2.84$$ GeV, with a wide coverage in the production angle. As seen in previous LEPS results, the differential cross-sections show a localized 'bump' between {radical}s {approx} 2 and 2.2 GeV that is not expected from a simple Pomeron exchange picture. Comparisons between the charged- and neutral-mode results and possible effects from the K{sup +} {Lambda}(1520) channel are discussed. Our SDME results confirm the well-known deviations from t-channel helicity conservation (TCHC) for Pomeron exchange, but s-channel helicity conservation (SCHC) is also seen to be broken.« less

  17. Surface and subsurface sensor performance in acoustically detecting western drywood termites in naturally infested boards.

    Treesearch

    V.R. Lewis; A.B. Power; M.I. Haverty

    2004-01-01

    Field-collected boards showing visual signs of damage by the western drywood termite, Incisitermes minor, were searched with a portable acoustic emission (AE) device. Depending on cross-sectional size, boards were either searched with a flat sensor that was hot-melt-glued to the wood surface or a subsurface sensor that wasthreaded 20 mm into the...

  18. Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages

    DOE PAGES

    Carlton, Holly D.; Elmer, John W.; Li, Yan; ...

    2016-04-13

    For this study synchrotron radiation micro-­tomography, a non-destructive three-dimensional imaging technique, is employed to investigate an entire microelectronic package with a cross-sectional area of 16 x 16 mm. Due to the synchrotron’s high flux and brightness the sample was imaged in just 3 minutes with an 8.7 μm spatial resolution.

  19. Assessing the performance of a cold region evapotranspiration landfill cover using lysimetry and electrical resistivity tomography.

    PubMed

    Schnabel, William E; Munk, Jens; Abichou, Tarek; Barnes, David; Lee, William; Pape, Barbara

    2012-01-01

    In order to test the efficacy ofa cold-region evapotranspiration (ET) landfill cover against a conventional compacted clay (CCL) landfill cover, two pilot scale covers were constructed in side-by-side basin lysimeters (20m x 10m x 2m) at a site in Anchorage, Alaska. The primary basis of comparison between the two lysimeters was the percolation of moisture from the bottom of each lysimeter. Between 30 April 2005 and 16 May 2006, 51.5 mm of water percolated from the ET lysimeter, compared to 50.6 mm for the the CCL lysimeter. This difference was not found to be significant at the 95% confidence level. As part of the project, electrical resistivity tomography (ERT) was utilized to measure and map soil moisture in ET lysimeter cross sections. The ERT-generated cross sections were found to accurately predict the onset and duration of lysimeter percolation. Moreover, ERT-generated soil moisture values demonstrated a strong linear relationship to lysimeter percolation rates (R-Squared = 0.92). Consequently, ERT is proposed as a reliable tool for assessing the function of field scale ET covers in the absence of drainage measurement devices.

  20. Thermal neutron capture and resonance integral cross sections of 45Sc

    NASA Astrophysics Data System (ADS)

    Van Do, Nguyen; Duc Khue, Pham; Tien Thanh, Kim; Thi Hien, Nguyen; Kim, Guinyun; Kim, Kwangsoo; Shin, Sung-Gyun; Cho, Moo-Hyun; Lee, Manwoo

    2015-11-01

    The thermal neutron cross section (σ0) and resonance integral (I0) of the 45Sc(n,γ)46Sc reaction have been measured relative to that of the 197Au(n,γ)198Au reaction by means of the activation method. High-purity natural scandium and gold foils without and with a cadmium cover of 0.5 mm thickness were irradiated with moderated pulsed neutrons produced from the Pohang Neutron Facility (PNF). The induced activities in the activated foils were measured with a high purity germanium (HPGe) detector. In order to improve the accuracy of the experimental results the counting losses caused by the thermal (Gth) and resonance (Gepi) neutron self-shielding, the γ-ray attenuation (Fg) and the true γ-ray coincidence summing effects were made. In addition, the effect of non-ideal epithermal spectrum was also taken into account by determining the neutron spectrum shape factor (α). The thermal neutron cross-section and resonance integral of the 45Sc(n,γ)46Sc reaction have been determined relative to the reference values of the 197Au(n,γ)198Au reaction, with σo,Au = 98.65 ± 0.09 barn and Io,Au = 1550 ± 28 barn. The present thermal neutron cross section has been determined to be σo,Sc = 27.5 ± 0.8 barn. According to the definition of cadmium cut-off energy at 0.55 eV, the present resonance integral cross section has been determined to be Io,Sc = 12.4 ± 0.7 barn. The present results are compared with literature values and discussed.

  1. Three Toxic Heavy Metals in Open-Angle Glaucoma with Low-Teen and High-Teen Intraocular Pressure: A Cross-Sectional Study from South Korea.

    PubMed

    Lee, Si Hyung; Kang, Eun Min; Kim, Gyu Ah; Kwak, Seung Woo; Kim, Joon Mo; Bae, Hyoung Won; Seong, Gong Je; Kim, Chan Yun

    2016-01-01

    To investigate the association between heavy metal levels and open-angle glaucoma (OAG) with low- and high-teen baseline intraocular pressure (IOP) using a population-based study design. This cross-sectional study included 5,198 participants older than 19 years of age who participated in the Korean National Health and Nutrition Examination Survey (KNHANES) from 2008 to 2012 and had blood heavy metal levels available. The OAG with normal baseline IOP (IOP ≤ 21 mmHg) subjects were stratified into low-teen OAG (baseline IOP ≤ 15 mmHg) and high-teen OAG (15 mmHg < baseline IOP ≤ 21 mmHg), and the association between blood lead, mercury, and cadmium levels and glaucoma prevalence was assessed for low- and high-teen OAG. The adjusted geometric mean of blood cadmium levels was significantly higher in subjects with low-teen OAG than that of the non-glaucomatous group (P = 0.028), whereas there were no significant differences in blood lead and mercury levels. After adjusting for potential confounders, the low-teen OAG was positively associated with log-transformed blood cadmium levels (OR, 1.41; 95% confidence interval (CI), 1.03-1.93; P = 0.026). For high-teen OAG, log-transformed blood levels of the three heavy metals were not associated with disease prevalence. The association between log-transformed blood cadmium levels and low-teen OAG was significant only in men (OR, 1.65; 95% CI, 1.10-2.48; P = 0.016), and not in women (OR, 1.10; 95% CI, 0.66-1.85; P = 0.709). The results of this study suggest that cadmium toxicity could play a role in glaucoma pathogenesis, particularly in men and in OAG with low-teen baseline IOP.

  2. Gazpacho consumption is associated with lower blood pressure and reduced hypertension in a high cardiovascular risk cohort. Cross-sectional study of the PREDIMED trial.

    PubMed

    Medina-Remón, A; Vallverdú-Queralt, A; Arranz, S; Ros, E; Martínez-González, M A; Sacanella, E; Covas, M I; Corella, D; Salas-Salvadó, J; Gómez-Gracia, E; Ruiz-Gutiérrez, V; Lapetra, J; García-Valdueza, M; Arós, F; Saez, G T; Serra-Majem, L; Pinto, X; Vinyoles, E; Estruch, R; Lamuela-Raventos, R M

    2013-10-01

    Hypertension is a major public health problem and a leading cause of death and disability in both developed and developing countries, affecting one-quarter of the world's adult population. Our aim was to evaluate whether the consumption of gazpacho, a Mediterranean vegetable-based cold soup rich in phytochemicals, is associated with lower blood pressure (BP) and/or reduced prevalence of hypertension in individuals at high cardiovascular risk. We selected 3995 individuals (58% women, mean age 67 y) at high cardiovascular risk (81% hypertensive) recruited into the PREDIMED study. BP, weight, and dietary and physical activity data were collected. In multivariate linear regression analyses, after adjustment, moderate and high gazpacho consumption categories were associated with reduced mean systolic BP of -1.9 mm Hg [95% confidence interval (CI): -3.4; -0.6] and -2.6 mm Hg (CI: -4.2; -1.0), respectively, and reduced diastolic BP of -1.5 mm Hg (CI: -2.3; -0.6) and -1.9 mm Hg (CI: -2.8; -1.1). By multiple-adjusted logistic regression analysis, gazpacho consumption was associated with a lower prevalence of hypertension, with OR = 0.85 (CI: 0.73; 0.99) for each 250 g/week increase and OR = 0.73 (CI: 0.55; 0.98) for high gazpacho consumption groups compared to the no-consumption group. Gazpacho consumption was inversely associated with systolic and diastolic BP and prevalence of hypertension in a cross-sectional Mediterranean population at high cardiovascular risk. The association between gazpacho intake and reduction of BP is probably due to synergy among several bioactive compounds present in the vegetable ingredients used to make the recipe. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. A Comparison of Ultrasound and MRI Measurements of the Cross-Sectional Area of the Median Nerve at the Wrist.

    PubMed

    Hersh, Beverly; D'Auria, Jennifer; Scott, Michael; Fowler, John R

    2018-05-01

    Ultrasound (US) measurement of cross-sectional area (CSA) of the median nerve has emerged as a viable alternative to electromyography/nerve conduction studies (EMG/NCS) for diagnosis of carpal tunnel syndrome (CTS). The purpose of this study is to compare CSA of the median nerve between US and MRI using current MRI and US technology. The null hypothesis is there is no difference between US and MRI CSA measurements. The study design was an observational cohort, enrolling patients presenting to clinic with MRI of the wrist. Participants with clinical signs and symptoms of CTS were excluded. The CSA measurements of the median nerve on MRI T1-weighted axial images were performed by a hand fellow blinded to results of US measurements, and US measurement of median nerve CSA was performed by a hand fellowship trained surgeon blinded to results of the MRI measurements. Results were analyzed via percent error, Pearson correlation, and t tests. Twenty participants were enrolled with mean age of 29.4 years. Four left wrists and 16 right wrists were measured. The US mean CSA of the median nerve was 6.8 mm 2 (±2.330 mm 2 ). The MRI mean CSA of the median nerve was 6.8 mm 2 (±2.153 mm 2 ), P = .442. Pearson correlation between modalities was 0.93, suggesting near-perfect correlation. Mean percent error was 8.8%. Results of this study suggest that US is an accurate method to measure CSA of the median nerve at the carpal tunnel inlet. The mean difference between US and MRI was unlikely to be clinically significant.

  4. Effect of ceramic infrastructure on the failure behavior and stress distribution of fixed partial dentures.

    PubMed

    Borba, Márcia; Duan, Yuanyuan; Griggs, Jason A; Cesar, Paulo F; Della Bona, Álvaro

    2015-04-01

    The effect of the ceramic infrastructure (IS) on the failure behavior and stress distribution of fixed partial dentures (FPDs) was evaluated. Twenty FPDs with a connector cross-section of 16 mm(2) were produced for each IS and veneered with porcelain: (YZ) Vita In-Ceram YZ/Vita VM9 porcelain; (IZ) Vita In-Ceram Zirconia/Vita VM7 porcelain; (AL) Vita In-Ceram AL/Vita VM7 porcelain. Two experimental conditions were evaluated (n = 10). For control specimens, load was applied in the center of the pontic at 0.5 mm/min until failure, using a universal testing machine, in 37°C deionized water. For mechanical cycling (MC) specimens, FPDs were subjected to MC (2 Hz, 140 N, 10(6) cycles) and subsequently tested as described for the control group. For YZ, an extra group of 10 FPDs were built with a connector cross-section of 9 mm(2) and tested until failure. Fractography and FEA were performed. Data were analyzed by ANOVA and Tukey's test (α = 0.05). YZ16 showed the greatest fracture load mean value, followed by YZ16-MC. Specimens from groups YZ9, IZ16, IZ16-MC, AL16 and AL16-MC showed no significant difference for the fracture load. The failure behavior and stress distribution of FPDs was influenced by the type of IS. AL and IZ FPDs showed similar fracture load values but different failure modes and stress distribution. YZ showed the best mechanical behavior and may be considered the material of choice to produce posterior FPDs as it was possible to obtain a good mechanical performance even with a smaller connector dimension (9 mm(2)). Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  5. Anatomical reconstructions of pediatric airways from endoscopic images: a pilot study of the accuracy of quantitative endoscopy.

    PubMed

    Meisner, Eric M; Hager, Gregory D; Ishman, Stacey L; Brown, David; Tunkel, David E; Ishii, Masaru

    2013-11-01

    To evaluate the accuracy of three-dimensional (3D) airway reconstructions obtained using quantitative endoscopy (QE). We developed this novel technique to reconstruct precise 3D representations of airway geometries from endoscopic video streams. This method, based on machine vision methodologies, uses a post-processing step of the standard videos obtained during routine laryngoscopy and bronchoscopy. We hypothesize that this method is precise and will generate assessment of airway size and shape similar to those obtained using computed tomography (CT). This study was approved by the institutional review board (IRB). We analyzed video sequences from pediatric patients receiving rigid bronchoscopy. We generated 3D scaled airway models of the subglottis, trachea, and carina using QE. These models were compared to 3D airway models generated from CT. We used the CT data as the gold standard measure of airway size, and used a mixed linear model to estimate the average error in cross-sectional area and effective diameter for QE. The average error in cross sectional area (area sliced perpendicular to the long axis of the airway) was 7.7 mm(2) (variance 33.447 mm(4)). The average error in effective diameter was 0.38775 mm (variance 2.45 mm(2)), approximately 9% error. Our pilot study suggests that QE can be used to generate precise 3D reconstructions of airways. This technique is atraumatic, does not require ionizing radiation, and integrates easily into standard airway assessment protocols. We conjecture that this technology will be useful for staging airway disease and assessing surgical outcomes. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  6. Monoclonal gammopathy of undetermined significance (MGUS) and smoldering myeloma (SMM): a practical guide to management.

    PubMed

    Maciocia, Nicola; Wechalekar, Ashutosh; Yong, Kwee

    2017-12-01

    Monoclonal gammopathy of undetermined significance and smoldering multiple myeloma are precursor conditions of symptomatic multiple myeloma (MM). Diagnostic principles are aimed at excluding MM requiring therapy, other conditions associated with paraproteins that may require different management, and risk stratifying patients for the purposes of tailored follow-up and investigation. The International Myeloma Working Group have recently published a revised definition of MM, which singles out a small group of patients with smoldering multiple myeloma who are at very high risk of progression and organ damage; such patients are now included under the definition of MM and recommended to start anti-myeloma treatment. Furthermore, the recently published National Institute of Health and Care Excellence guideline recommends cross-sectional imaging techniques in place of skeletal survey. These recent recommendations are discussed, and practical guidance for investigation and management are presented. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Whole-body ring-shaped confocal photoacoustic computed tomography of small animals in vivo.

    PubMed

    Xia, Jun; Chatni, Muhammad R; Maslov, Konstantin; Guo, Zijian; Wang, Kun; Anastasio, Mark; Wang, Lihong V

    2012-05-01

    We report a novel small-animal whole-body imaging system called ring-shaped confocal photoacoustic computed tomography (RC-PACT). RC-PACT is based on a confocal design of free-space ring-shaped light illumination and 512-element full-ring ultrasonic array signal detection. The free-space light illumination maximizes the light delivery efficiency, and the full-ring signal detection ensures a full two-dimensional view aperture for accurate image reconstruction. Using cylindrically focused array elements, RC-PACT can image a thin cross section with 0.10 to 0.25 mm in-plane resolutions and 1.6  s/frame acquisition time. By translating the mouse along the elevational direction, RC-PACT provides a series of cross-sectional images of the brain, liver, kidneys, and bladder.

  8. Whole-body ring-shaped confocal photoacoustic computed tomography of small animals in vivo

    NASA Astrophysics Data System (ADS)

    Xia, Jun; Chatni, Muhammad R.; Maslov, Konstantin; Guo, Zijian; Wang, Kun; Anastasio, Mark; Wang, Lihong V.

    2012-05-01

    We report a novel small-animal whole-body imaging system called ring-shaped confocal photoacoustic computed tomography (RC-PACT). RC-PACT is based on a confocal design of free-space ring-shaped light illumination and 512-element full-ring ultrasonic array signal detection. The free-space light illumination maximizes the light delivery efficiency, and the full-ring signal detection ensures a full two-dimensional view aperture for accurate image reconstruction. Using cylindrically focused array elements, RC-PACT can image a thin cross section with 0.10 to 0.25 mm in-plane resolutions and 1.6 s/frame acquisition time. By translating the mouse along the elevational direction, RC-PACT provides a series of cross-sectional images of the brain, liver, kidneys, and bladder.

  9. Racial disparity in blood pressure: is vitamin D a factor?

    PubMed

    Fiscella, Kevin; Winters, Paul; Tancredi, Dan; Franks, Peter

    2011-10-01

    Higher prevalence of hypertension among African Americans is a key cause of racial disparity in cardiovascular morbidity and mortality. Explanations for the difference in prevalence are incomplete. Emerging data suggest that low vitamin D levels may contribute. To assess the contribution of vitamin D to racial disparity in blood pressure. Cross-sectional analysis. Adult non-Hispanic Black and White participants from the National Health and Nutrition Examination Survey 2001-2006. We assessed Black-White differences in systolic blood pressure (SBP) controlling for conventional risk factors, and then additionally, for vitamin D (serum 25[OH]D). The sample included 1984 and 5156 Black and White participants ages 20 years and older. The mean age-sex adjusted Black-White SBP difference was 5.2 mm Hg. This difference was reduced to 4.0 mm Hg with additional adjustment for socio-demographic characteristics, health status, health care, health behaviors, and biomarkers; adding 25(OH)D reduced the race difference by 26% (95% CI 7-46%) to 2.9 mm Hg. This effect increased to 39% (95% CI 14-65%) when those on antihypertensive medications were excluded. Supplementary analyses that controlled for cardiovascular fitness, percent body fat, physical activity monitoring, skin type and social support yielded consistent results. In cross-sectional analyses, 25(OH)D explains one quarter of the Black-White disparity in SBP. Randomized controlled trials are required to determine whether vitamin D supplementation could reduce racial disparity in BP.

  10. Ultrahigh speed endoscopic swept source optical coherence tomography using a VCSEL light source and micromotor catheter

    NASA Astrophysics Data System (ADS)

    Tsai, Tsung-Han; Ahsen, Osman O.; Lee, Hsiang-Chieh; Liang, Kaicheng; Giacomelli, Michael G.; Potsaid, Benjamin M.; Tao, Yuankai K.; Jayaraman, Vijaysekhar; Kraus, Martin F.; Hornegger, Joachim; Figueiredo, Marisa; Huang, Qin; Mashimo, Hiroshi; Cable, Alex E.; Fujimoto, James G.

    2014-03-01

    We developed an ultrahigh speed endoscopic swept source optical coherence tomography (OCT) system for clinical gastroenterology using a vertical-cavity surface-emitting laser (VCSEL) and micromotor based imaging catheter, which provided an imaging speed of 600 kHz axial scan rate and 8 μm axial resolution in tissue. The micromotor catheter was 3.2 mm in diameter and could be introduced through the 3.7 mm accessory port of an endoscope. Imaging was performed at 400 frames per second with an 8 μm spot size using a pullback to generate volumetric data over 16 mm with a pixel spacing of 5 μm in the longitudinal direction. Three-dimensional OCT (3D-OCT) imaging was performed in patients with a cross section of pathologies undergoing standard upper and lower endoscopy at the Veterans Affairs Boston Healthcare System (VABHS). Patients with Barrett's esophagus, dysplasia, and inflammatory bowel disease were imaged. The use of distally actuated imaging catheters allowed OCT imaging with more flexibility such as volumetric imaging in the terminal ileum and the assessment of the hiatal hernia using retroflex imaging. The high rotational stability of the micromotor enabled 3D volumetric imaging with micron scale volumetric accuracy for both en face and cross-sectional imaging. The ability to perform 3D OCT imaging in the GI tract with microscopic accuracy should enable a wide range of studies to investigate the ability of OCT to detect pathology as well as assess treatment response.

  11. Mechanism of formation and spatial distribution of lead atoms in quartz tube atomizers

    NASA Astrophysics Data System (ADS)

    Johansson, M.; Baxter, D. C.; Ohlsson, K. E. A.; Frech, W.

    1997-05-01

    The cross-sectional and longitudinal spatial distributions of lead atoms in a quartz tube (QT) atomizers coupled to a gas chromatograph have been investigated. A uniform analyte atom distribution over the cross-section was found in a QT having an inner diameter (i.d.) of 7 mm, whereas a 10 mm i.d. QT showed an inhomogeneous distribution. These results accentuate the importance of using QTs with i.d.s below 10 mm to fulfil the prerequirement of the Beer—Lambert law to avoid bent calibration curves. The influence of the make up gas on the formation of lead atoms from alkyllead compounds has been studied, and carbon monoxide was found equally efficient in promoting free atom formation as hydrogen. This suggests that hydrogen radicals are not essential for mediating the atomization of alkyllead in QT atomizers at ˜ 1200 K. Furthermore, thermodynamic equilibrium calculations describing the investigated system were performed supporting the experimental results. Based on the presented data, a mechanism for free lead atom formation in continuously heated QT atomizers is proposed; thermal atomization occurs under thermodynamic equilibrium conditions in a reducing gas. The longitudinal atom distribution has been further investigated applying other make up gases, N 2 and He. These results show the effect of the influx of atmospheric oxygen on the free lead atom formation. Calculations of the partial pressure of oxygen in the atomizer gas phase assuming thermodynamic equilibrium have been undertaken using a convective-diffusional model.

  12. Effect of resistance exercise training combined with relatively low vascular occlusion.

    PubMed

    Sumide, Takahiro; Sakuraba, Keishoku; Sawaki, Keisuke; Ohmura, Hirotoshi; Tamura, Yoshifumi

    2009-01-01

    Previous studies have demonstrated that a low-intensity resistance exercise, combined with vascular occlusion, results in a marked increase in muscular size and strength. We investigated the optimal pressure for reduction of muscle blood flow with resistance exercise to increase the muscular strength and endurance. Twenty-one subjects were randomly divided into four groups by the different application of vascular occlusion pressure at the proximal of thigh: without any pressure (0-pressure group), with a pressure of 50mmHg (50-pressure group), with a pressure of 150mmHg (150-pressure group), and with a pressure of 250mmHg (250-pressure group). The isokinetic muscle strength at angular velocities of 60 and 180 degrees /s, total muscle work, and the cross-sectional knee extensor muscle area were assessed before and after exercise. Exercise was performed three times a week over an 8-week period at an intensity of approximately 20% of one-repetition maximum for straight leg raising and hip joint adduction and maximum force for abduction training. A significant increase in strength at 180 degrees /s was noted after exercise in all subjects who exercised under vascular occlusion. Total muscle work increased significantly in the 50- and 150-pressure groups (P<0.05, P<0.01, respectively). There was no significant increase in cross-sectional knee extensor muscle area in any groups. In conclusion, resistance exercise with relatively low vascular occlusion pressure is potentially useful to increase muscle strength and endurance without discomfort.

  13. Design and Characterization of the UTIAS Anechoic Wind Tunnel

    NASA Astrophysics Data System (ADS)

    Chow, Derrick H. F.

    The anechoic open-jet wind tunnel facility at the University of Toronto Institute for Aerospace Studies was updated and characterized to meet the needs of current and future aeroacoustic experiments. The wind tunnel inlet was resurfaced and flow-conditioning screens were redesigned to improve the freestream turbulence intensity to below 0.4% in the test section. The circular nozzle was replaced with a square secondary contraction that increased the maximum test section velocity to 75 m/s and improved flow uniformity to over 99% across a usable cross-sectional area of 500 mm x 500 mm. Acoustic baffles were installed in front of the wind tunnel inlet and foam wedges were installed in the anechoic chamber. The overall background sound pressure levels in the chamber were improved by 8-18 db over the range of operational freestream velocities. The anechoic chamber cut-off frequency is 170 Hz and the reverberation time for a 60 dB sound power decay is 0.032 s.

  14. Air Gaps, Size Effect, and Corner-Turning in Ambient LX-17

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Souers, P C; Hernandez, A; Cabacungan, C

    2008-02-05

    Various ambient measurements are presented for LX-17. The size (diameter) effect has been measured with copper and Lucite confinement, where the failure radii are 4.0 and 6.5 mm, respectively. The air well corner-turn has been measured with an LX-07 booster, and the dead-zone results are comparable to the previous TATB-boosted work. Four double cylinders have been fired, and dead zones appear in all cases. The steel-backed samples are faster than the Lucite-backed samples by 0.6 {micro}s. Bare LX-07 and LX-17 of 12.7 mm-radius were fired with air gaps. Long acceptor regions were used to truly determine if detonation occurred ormore » not. The LX-07 crossed at 10 mm with a slight time delay. Steady state LX-17 crossed at 3.5 mm gap but failed to cross at 4.0 mm. LX-17 with a 12.7 mm run after the booster crossed a 1.5 mm gap but failed to cross 2.5 mm. Timing delays were measured where the detonation crossed the gaps. The Tarantula model is introduced as embedded in 0 reactive flow JWL++ and Linked Cheetah V4, mostly at 4 zones/mm. Tarantula has four pressure regions: off, initiation, failure and detonation. The physical basis of the input parameters is considered.« less

  15. Bone geometry, strength, and muscle size in runners with a history of stress fracture.

    PubMed

    Popp, Kristin L; Hughes, Julie M; Smock, Amanda J; Novotny, Susan A; Stovitz, Steven D; Koehler, Scott M; Petit, Moira A

    2009-12-01

    Our primary aim was to explore differences in estimates of tibial bone strength, in female runners with and without a history of stress fractures. Our secondary aim was to explore differences in bone geometry, volumetric density, and muscle size that may explain bone strength outcomes. A total of 39 competitive distance runners aged 18-35 yr, with (SFX, n = 19) or without (NSFX, n = 20) a history of stress fracture were recruited for this cross-sectional study. Peripheral quantitative computed tomography (XCT 3000; Orthometrix, White Plains, NY) was used to assess volumetric bone mineral density (vBMD, mg x mm(-3)), bone area (ToA, mm(2)), and estimated compressive bone strength (bone strength index (BSI) = ToA x total volumetric density (ToD(2))) at the distal tibia (4%). Total (ToA, mm(2)) and cortical (CoA, mm(2)) bone area, cortical vBMD, and estimated bending strength (strength-strain index (SSIp), mm(3)) were measured at the 15%, 25%, 33%, 45%, 50%, and 66% sites. Muscle cross-sectional area (MCSA) was measured at the 50% and 66% sites. Participants in the SFX group had significantly smaller (7%-8%) CoA at the 45%, 50%, and 66% sites (P

  16. Normal Cerebellar Growth by Using Three-dimensional US in the Preterm Infant from Birth to Term-corrected Age.

    PubMed

    Benavente-Fernández, Isabel; Rodríguez-Zafra, Enrique; León-Martínez, Jesús; Jiménez-Gómez, Gema; Ruiz-González, Estefanía; Fernández-Colina, Rosalía Campuzano; Lechuga-Sancho, Alfonso M; Lubián-López, Simón P

    2018-04-03

    Purpose To establish cross-sectional and longitudinal reference values for cerebellar size in preterm infants with normal neuroimaging findings and normal 2-year neurodevelopmental outcome by using cranial ultrasonography (US). Materials and Methods This prospective study consecutively enrolled preterm infants admitted to a neonatal intensive care unit from June 2011 to June 2014 with a birth weight of less than or equal to 1500 g and/or gestational age (GA) of less than or equal to 32 weeks. They underwent weekly cranial US from birth to term-equivalent age and magnetic resonance (MR) imaging at term-equivalent age. The infants underwent neurodevelopmental assessments at age 2 years with Bayley Scales of Infant and Toddler Development, 3rd edition (BSID-III). Patients with adverse outcomes (death or abnormal neuroimaging findings and/or BSID-III score of <85) were excluded. The following measurements were performed: vermis height, craniocaudal diameter, superior width, inferior width, vermis area, and transcerebellar diameter. Statistical analyses were conducted by using multilevel analyses. Results A total of 137 infants with a mean GA at birth of 29.4 weeks (range, 25-32 weeks) were included. Transcerebellar diameter increased by 1.04 mm per week on average; vermis height and craniocaudal diameter increased by 0.55 mm and 0.59 mm, respectively. Superior vermian width increased by an average of 0.45 mm, whereas inferior vermian width increased by an average of 0.51 mm per week. Vermis area was found to increase by 0.22 cm 2 per week on average. The sex effect was significant (female lower than male) for vermis height (P < .05), craniocaudal diameter (P < .05), inferior vermian width (P <. 05), and vermis area (P <. 05). Conclusion Cross-sectional and longitudinal reference values were established for cerebellar growth in preterm infants, which may be included in routine cranial US. © RSNA, 2018 Online supplemental material is available for this article.

  17. Digital tooth-based superimposition method for assessment of alveolar bone levels on cone-beam computed tomography images.

    PubMed

    Romero-Delmastro, Alejandro; Kadioglu, Onur; Currier, G Frans; Cook, Tanner

    2014-08-01

    Cone-beam computed tomography images have been previously used for evaluation of alveolar bone levels around teeth before, during, and after orthodontic treatment. Protocols described in the literature have been vague, have used unstable landmarks, or have required several software programs, file conversions, or hand tracings, among other factors that could compromise the precision of the measurements. The purposes of this article are to describe a totally digital tooth-based superimposition method for the quantitative assessment of alveolar bone levels and to evaluate its reliability. Ultra cone-beam computed tomography images (0.1-mm reconstruction) from 10 subjects were obtained from the data pool of the University of Oklahoma; 80 premolars were measured twice by the same examiner and a third time by a second examiner to determine alveolar bone heights and thicknesses before and more than 6 months after orthodontic treatment using OsiriX (version 3.5.1; Pixeo, Geneva, Switzerland). Intraexaminer and interexaminer reliabilities were evaluated, and Dahlberg's formula was used to calculate the error of the measurements. Cross-sectional and longitudinal evaluations of alveolar bone levels were possible using a digital tooth-based superimposition method. The mean differences for buccal alveolar crest heights and thicknesses were below 0.10 mm for the same examiner and below 0.17 mm for all examiners. The ranges of errors for any measurement were between 0.02 and 0.23 mm for intraexaminer errors, and between 0.06 and 0.29 mm for interexaminer errors. This protocol can be used for cross-sectional or longitudinal assessment of alveolar bone levels with low interexaminer and intraexaminer errors, and it eliminates the use of less reliable or less stable landmarks and the need for multiple software programs and image printouts. Standardization of the methods for bone assessment in orthodontics is necessary; this method could be the answer to this need. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  18. Analysis of internal structure changes in black human hair keratin fibers with aging using Raman spectroscopy.

    PubMed

    Kuzuhara, Akio; Fujiwara, Nobuki; Hori, Teruo

    To investigate the internal structure changes in virgin black human hair keratin fibers due to aging, the structure of cross-sections at various depths of virgin black human hair (sections of new growth hair: 2 mm from the scalp) from a group of eight Japanese females in their twenties and another group of eight Japanese females in their fifties were analyzed using Raman spectroscopy. For the first time, we have succeeded in recording the Raman spectra of virgin black human hair, which had been impossible due to high melanin granule content. The key points of this method are to cross-section hair samples to a thickness of 1.50-microm, to select points at various depths of the cortex with the fewest possible melanin granules, and to optimize laser power, cross slit width as well as total acquisition time. The reproducibility of the Raman bands, namely the alpha-helix (alpha) content, the beta-sheet and/or random coil (beta/R) content, the disulfide (--SS--) content, and random coil content of two adjoining cross-sections of a single hair keratin fiber was clearly good. The --SS-- content of virgin black human hair from the Japanese females in their fifties for the cortex region decreased compared with that of the Japanese females in their twenties. On the other hand, the beta/R and alpha contents of the cortex region did not change.

  19. Transverse Coefficient of Thermal Expansion Measurements of Carbon Fibers Using ESEM at High Temperatures

    NASA Technical Reports Server (NTRS)

    Ochoa, O.; Jiang, J.; Putnam, D.; Lo, Z.; Ellis, A.; Effinger, Michael

    2003-01-01

    The transverse coefficient of thermal expansion (CTE) of single IM7, T1000, and P55 carbon fibers are measured at elevated temperatures. The specimens are prepared by press-fitting fiber tows into 0.7mm-diameter cavity in a graphite disk of 5mm in diameter and 3mm high. The specimens are placed on a crucible in an ESEM, and images of the fiber cross section are taken as the fibers are heated up to 800 C. Holding time, heating and cool down cycles are also introduced. The geometrical changes are measured using a graphics tablet. The change in area/perimeter is calculated to determine the strain and transverse CTE for each fiber. In a complimentary computational effort, displacements and stresses are calculated with finite element models.

  20. Carotid Plaque Morphological Classification Compared With Biomechanical Cap Stress: Implications for a Magnetic Resonance Imaging-Based Assessment.

    PubMed

    Gijsen, Frank J H; Nieuwstadt, Harm A; Wentzel, Jolanda J; Verhagen, Hence J M; van der Lugt, Aad; van der Steen, Antonius F W

    2015-08-01

    Two approaches to target plaque vulnerability-a histopathologic classification scheme and a biomechanical analysis-were compared and the implications for noninvasive risk stratification of carotid plaques using magnetic resonance imaging were assessed. Seventy-five histological plaque cross sections were obtained from carotid endarterectomy specimens from 34 patients (>70% stenosis) and subjected to both a Virmani histopathologic classification (thin fibrous cap atheroma with <0.2-mm cap thickness, presumed vulnerable) and a peak cap stress computation (<140 kPa: presumed stable; >300 kPa: presumed vulnerable). To demonstrate the implications for noninvasive plaque assessment, numeric simulations of a typical carotid magnetic resonance imaging protocol were performed (0.62×0.62 mm(2) in-plane acquired voxel size) and used to obtain the magnetic resonance imaging-based peak cap stress. Peak cap stress was generally associated with histological classification. However, only 16 of 25 plaque cross sections could be labeled as high-risk (peak cap stress>300 kPa and classified as a thin fibrous cap atheroma). Twenty-eight of 50 plaque cross sections could be labeled as low-risk (a peak cap stress<140 kPa and not a thin fibrous cap atheroma), leading to a κ=0.39. 31 plaques (41%) had a disagreement between both classifications. Because of the limited magnetic resonance imaging voxel size with regard to cap thickness, a noninvasive identification of only a group of low-risk, thick-cap plaques was reliable. Instead of trying to target only vulnerable plaques, a more reliable noninvasive identification of a select group of stable plaques with a thick cap and low stress might be a more fruitful approach to start reducing surgical interventions on carotid plaques. © 2015 American Heart Association, Inc.

  1. Comparative evaluation of cyclic fatigue resistance of four different nickel-titanium rotary files with different cross-sectional designs and alloy properties.

    PubMed

    Kaval, Mehmet Emin; Capar, Ismail Davut; Ertas, Hüseyin; Sen, Bilge Hakan

    2017-06-01

    The purpose of the present study was to evaluate the cyclic fatigue resistance of F6 SkyTaper (Komet Brasseler, Lemgo, Germany), K3XF (SybronEndo, Orange, CA, USA), new generation OneShape (Micro Mega, Besancon, France) and TRUShape 3D conforming files (Dentsply Tulsa Dental Specialties, Tulsa, OK, USA). Ten instruments from each group were selected and allowed to rotate using a low-torque motor in a stainless steel block with 1.5 mm diameter, 3 mm radius of 60° angle of curvature at the manufacturer's recommended speed, and the number of cycles (NCF) from the beginning to the fracture was recorded. The data were analyzed using one-way ANOVA followed by post-hoc Tukey's test (P = 0.05). The ranking of the groups from the highest to the lowest NCF was as follows: F6 SkyTaper (959 ± 92), K3XF (725 ± 71), TRUShape (575 ± 84) and OneShape (289 ± 58). Statistically significant differences were detected between all groups (P < 0.05). Within the limitations of this study, F6 SkyTaper instruments presented the highest cyclic fatigue resistance among the tested instruments. The S-shaped cross-sectional design of F6 SkyTaper instruments could be the most important factor on the superior cyclic life span of these instruments. In endodontic practice, preferring the instruments with higher cyclic fatigue resistance would help to minimize the risk of instrument fractures; therefore especially during the preparation of curved canals, instruments with smaller core area and less cross-sectional metal mass, which could lead higher flexibility, can be proposed.

  2. Prognostic Significance of Spot Urine Na/K for Longitudinal Changes in Blood Pressure and Renal Function: The Nagahama Study.

    PubMed

    Tabara, Yasuharu; Takahashi, Yoshimitsu; Setoh, Kazuya; Kawaguchi, Takahisa; Kosugi, Shinji; Nakayama, Takeo; Matsuda, Fumihiko

    2017-09-01

    Urinary sodium-to-potassium ratio (Na/K) represents a simple measure of sodium load and has been reported to be associated with blood pressure (BP) levels in a cross-sectional setting even with spot measurements. The aim of the present large-scale cohort study is to determine prognostic significance of spot urine Na/K for longitudinal changes in BP levels and renal function. The present study population consisted of 7,063 individuals from the general population. Clinical parameters were measured at baseline and at a follow-up interval of 5 years. Mean systolic BP was slightly increased during the follow-up period (overall, 124 ± 17 to 125 ± 18 mm Hg; nontreated participants, 119 ± 15 to 122 ± 17 mm Hg). Although, the urinary Na/K demonstrated a linear association with BP in a cross-sectional analysis (P < 0.001), analysis of repeated measured BP values identified baseline Na/K * time interaction, i.e., an intraindividual effect, as an inverse determinant (F = 76.9, P < 0.001) independently of hypertension status and fasting conditions possibly due to regression to the mean of temporary high baseline Na/K values at baseline. Spot urine Na/K values were found to be positively associated with renal function in a cross-sectional analysis (P < 0.001). Although baseline Na/K * time interaction showed inverse associated with renal functional decline (F = 85.8, P < 0.001), this inverse association might not represent physiological relationship in likewise fashion with the analysis for BP. Spot urine Na/K may have limited utility as a prognostic marker of longitudinal BP change, as well as renal functional decline. © American Journal of Hypertension, Ltd 2017. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  3. Anthropometry and blood pressure changes in a Caribbean adolescent population of African ancestry: an evaluation of longitudinal data using a multilevel mixed regression approach.

    PubMed

    Nichols, S; Cadogan, F

    2012-10-01

    The aim of this study was to determine the effect of growth pattern on blood pressure changes in an adolescent population of African ancestry based on longitudinal data and to compare this with estimates derived from cross-sectional data. Participants had measurements of weight, height, blood pressure and percentage body fat taken annually using standardized procedures. Annual blood pressure and anthropometry velocities as well as one- and three-year interval gender specific tracking coefficients were computed. We investigated whether changes in blood pressure could be explained by measures of growth using a multilevel mixed regression approach. The results showed that systolic blood pressure (SBP) increased by 1.27 and 3.09 mmHg per year among females and males, respectively. Similarly, diastolic blood pressure (DBP) increased by 1.16 and 1.92 mmHg per year among females and males, respectively. Multilevel analyses suggested that weight, body mass index, percentage body fat and height were the strongest anthropometric determinants of blood pressure change in this population. The results also suggest that there are gender differences in the relative importance of these anthropometric measures with height playing a minor role in predicting blood pressure changes among adolescent females. With the exception of DBP at 18 years among females, there were no significant differences between mean blood pressure generated from cross-sectional and longitudinal data by age in both males and females. Anthropometric measures are important covariates of age-related blood pressure changes and cross-sectional data may provide a more cost-effective and useful proxy for generating age-related blood pressure estimates in this population.

  4. The temperature dependence of the tensile properties of thermally treated Alloy 690 tubing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harrod, D.L.; Gold, R.E.; Larsson, B.

    1992-12-31

    Tensile tests were run in air on full tube cross-sections of 22.23 mm OD by 1.27 mm wall thickness Alloy 690 steam generator production tubes from ten (10) heats of material at eight (8) temperatures between room temperature and 760{degrees}C. The tubing was manufactured to specification requirements consistent with the EPRI guidelines for Alloy 690 tubing. The room temperature stress-strain curves are described quite well by the Voce equation. Ductile fracture by dimpled rupture was observed at all test temperatures. The elevated temperature tensile properties are compared with design data given in the ASME Code.

  5. Plasma sprayed Fe(76)Nd(16)B(8) permanent magnets

    NASA Technical Reports Server (NTRS)

    Overfelt, R. A.; Anderson, C. D.; Flanagan, W. F.

    1986-01-01

    Thin coatings (0.16 mm) and thick coatings (0.50 mm) of Fe(76)Nd(16)B(8) were deposited on stainless-steel substrates by low pressure plasma spraying. Microscopic examination of the coatings in a light microscope revealed excessive porosity, but good bonding to the substrate. Fracture cross sections examined in a scanning electron microscope showed the grains to be equiaxed and approximately 1 micron or less in diameter in the as-sprayed condition. The intrinsic coercivities of the as-sprayed coatings varied from 5.8 to 10.9 kOe. The effects of postspray heat treatments on the intrinsic coercivity are also given.

  6. Development of a miniaturized hour-glass shaped fatigue specimen

    NASA Astrophysics Data System (ADS)

    Miwa, Y.; Jitsukawa, S.; Hishinuma, A.

    1998-10-01

    Diametral strain-controlled push-pull fatigue tests with zero mean strain were carried out with miniaturized hour-glass shaped specimens of an austenitic stainless steel in solution annealed condition at room temperature. The specimens had a diameter of 1.25 mm at the minimum cross section and a total length of 25.4 mm. The number of cycles to failure ( Nf) was equal to or slightly greater than that obtained with standard size specimens. Nf was also revealed to be rather insensitive to the specimen load axis offset, indicating that the requirement of the specimen alignment to the load axis was not very severe for the miniaturized specimen.

  7. The New Dual-beam Spectropluviometer Concept

    NASA Astrophysics Data System (ADS)

    Delahaye, J. Y.; Barthes, L.; Golé, P.; Lavergnat, J.; Vinson, J. P.

    A Dual Beam Spectropluviometer (DBS) measuring the equivalent diameter D, the vertical velocity V and the time T of arrival of particles is presented. Its main advan- tage over previous optical disdrometers is the extensive measurement range of atmo- spheric precipitations near ground. In particular, 0.15 mm diameter particles can be observed in quiet laboratory conditions and 0.2 mm is the smallest diameter observed in the outdoor turbulent air velocity field. The means for obtaining such results are (i) two uniform beams of rectangular cross-section 2 mm in height, 40 mm in width and 250 mm in length, with a 2 mm vertical gap, (ii) a dual 16-bit analog to digital converter, (iii) a dedicated program for extracting the 3 parameters in real time by computing the signal slopes and determining the correlation between both channels, (iii) various means for reducing splashing and vibration. Laboratory tests and typical rain measurements are shown. The DBS is particularly suited for extensive atmospheric and radio propagation research applications where the smallest drops were not correctly estimated in the distributions because of the lack of appropriate measurement devices.

  8. Prognostic monitoring of aircraft wiring using electrical capacitive tomography

    NASA Astrophysics Data System (ADS)

    McKenzie, G.; Record, P.

    2011-12-01

    Electrical capacitive tomography (ECT) has been used to monitor sections of aircraft wiring, as a tool for prognostic analysis. To apply the principles of ECT across a cross section of only 4 mm, modification of the basic circuit was required. Additionally, a more novel method of placing the necessary electrodes was needed, this being accomplished by etching them from flexible copper sheeting and wrapping them inside the perimeter of an enclosure. Results showed that at this small scale, it was possible to determine the position of a wire-under-test inside the 4 mm diameter enclosure to about 0.1 mm, and that by measuring capacitance between pairs, it was also possible to determine whether or not the insulation of wire passed between the electrodes was damaged. With more than one wire-under-test present, it was possible to determine whether or not damage was present, and if so, which wire was damaged. By detecting insulation damage in this way, ECT has proven to be a useful tool in prognostic monitoring, helping faults to be found before they become safety-critical onboard an aircraft.

  9. Prognostic monitoring of aircraft wiring using electrical capacitive tomography.

    PubMed

    McKenzie, G; Record, P

    2011-12-01

    Electrical capacitive tomography (ECT) has been used to monitor sections of aircraft wiring, as a tool for prognostic analysis. To apply the principles of ECT across a cross section of only 4 mm, modification of the basic circuit was required. Additionally, a more novel method of placing the necessary electrodes was needed, this being accomplished by etching them from flexible copper sheeting and wrapping them inside the perimeter of an enclosure. Results showed that at this small scale, it was possible to determine the position of a wire-under-test inside the 4 mm diameter enclosure to about 0.1 mm, and that by measuring capacitance between pairs, it was also possible to determine whether or not the insulation of wire passed between the electrodes was damaged. With more than one wire-under-test present, it was possible to determine whether or not damage was present, and if so, which wire was damaged. By detecting insulation damage in this way, ECT has proven to be a useful tool in prognostic monitoring, helping faults to be found before they become safety-critical onboard an aircraft.

  10. Proposed alternative revision strategy for broken S1 pedicle screw: radiological study, review of the literature, and case reports.

    PubMed

    Elgafy, Hossein; Miller, Jacob D; Benedict, Gregory M; Seal, Ryan J; Liu, Jiayong

    2013-07-01

    There have been many reports outlining differing methods for managing a broken S1 screw. To the authors' best knowledge, the technique used in the present study has not been described previously. It involves insertion of a second pedicle screw without removing the broken screw shaft. Radiological study, literature review, and two case reports of the surgical technique. To report a proposed new surgical technique for management of broken S1 pedicle screws. Computed tomography (CT) scans of 50 patients with a total of 100 S1 pedicles were analyzed. There were 25 male and 25 female patients with an average age of 51 years ranging from 36 to 68 years. The cephalad-caudal length, medial-lateral width, and cross-sectional area of the S1 pedicle were measured and compared with the diameter of a pedicle screw to illustrate the possibility of inserting a second screw in S1 pedicle without removal of the broken screw shaft. Two case reports of the proposed technique are presented. The left and right S1 pedicle cross-sectional area in female measured 456.00 ± 4.00 and 457.00 ± 3.00 mm(2), respectively. The left and right S1 pedicle cross-section area in male measured 638.00 ± 2.00 and 639.00 ± 1.00 mm(2), respectively. There were statistically significant differences when comparing male and female S1 pedicle length, width, and cross-sectional area (p<.05). At 2-year follow-up, the two case reports of the proposed technique showed resolution of low back pain and radicular pain. Plain radiograph and CT scan showed posterolateral fusion mass and hardware in good position with no evidence of screw loosening. The S1 pedicle dimensions measured on CT scan reviewed in the present study showed that it may be anatomically feasible to place a second screw through the S1 pedicle without the removal of the broken screw shaft. This treatment method will reduce the complications associated with other described revision strategies for broken S1 screws. Published by Elsevier Inc.

  11. SU-E-U-02: The Development of a Practical Ultrasonic System for Cross-Sectional Imaging of Small Animals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kamp, J; Karmanos Cancer Institute - International Imaging Center, Detroit, MI; Malyarenko, E

    Purpose: To test the feasibility of developing a practical medium frequency ultrasound tomography method for small animal imaging. The ability to produce cross-sectional or full body images of a live small animal using a low-cost tabletop ultrasound scanner without any special license would be very beneficial to long term biological studies, where repeated scanning is often required over an extended period of time. Methods: The cross sectional images were produced by compounding multiple B-scans of a laboratory phantom or an animal acquired at different projection angles. Two imaging systems were used to test the concept. The first system included amore » programmable 64-channel phased array controller driving a 128-channel, 5–10 MHz linear probe to produce 143 B-Mode projections of the spinning object. The second system designed and manufactured in house, produced 64 or 128 B-Mode projections with a single unfocused 8 MHz transducer scanning with a 0.116 mm step size. Results: The phased array system provided good penetration through the phantoms/mice (with the exception of the lungs) and allowed to acquire data in a very short time. The cross-sectional images have enough resolution and dynamic range to detect both high- and low-contrast organs. The single transducer system takes longer to scan, and the data require more sophisticated processing. To date, our images allow seeing details as small as 1–2 mm in the phantoms and in small animals, with the contrast mostly due to highly reflecting bones and air inclusions. Conclusion: The work indicates that very detailed and anatomically correct images can be created by relatively simple and inexpensive means. With more advanced algorithms and improved system design, scan time can be reduced considerably, enabling high-resolution full 3D imaging. This will allow for quick and easy scans that can help monitor tumor growth and/or regression without contributing any dose to the animal. The authors would like to acknowledge the financial and engineering support from Tessonics.« less

  12. Upper Airway Changes after Orthodontic Extraction Treatment in Adults: A Preliminary Study using Cone Beam Computed Tomography

    PubMed Central

    Zhang, Jingjing; Chen, Gui; Li, Weiran; Xu, Tianmin; Gao, Xuemei

    2015-01-01

    Objective Whether the orthodontic treatment with premolar extraction and maximum anchorage in adults will lead to a narrowed upper airway remains under debated. The study aims to investigate the airway changes after orthodontic extraction treatment in adult patients with Class II and hyperdivergent skeletal malocclusion. Materials and Methods This retrospective study enrolled 18 adults with Class II and hyperdivergent skeletal malocclusion (5 males and 13 females, 24.1 ± 3.8 years of age, BMI 20.33 ± 1.77 kg/m2). And 18 untreated controls were matched 1:1 with the treated patients for age, sex, BMI, and skeletal pattern. CBCT images before and after treatment were obtained. DOLPHIN 11.7 software was used to reconstruct and measure the airway size, hyoid position, and craniofacial structures. Changes in the airway and craniofacial parameters from pre to post treatment were assessed by Wilcoxon signed rank test. Mann-Whitney U test was used in comparisons of the airway parameters between the treated patients and the untreated controls. Significant level was set at 0.05. Results The upper and lower incisors retracted 7.87 mm and 6.10 mm based on the measurement of U1-VRL and L1-VRL (P < 0.01), while the positions of the upper and lower molars (U6-VRL, and L6-VRL) remained stable. Volume, height, and cross-sectional area of the airway were not significantly changed after treatment, while the sagittal dimensions of SPP-SPPW, U-MPW, PAS, and V-LPW were significantly decreased (P < 0.05), and the morphology of the cross sections passing through SPP-SPPW, U-MPW, PAS, and V-LPW became anteroposteriorly compressed (P <0.001). No significant differences in the airway volume, height, and cross-sectional area were found between the treated patients and untreated controls. Conclusions The airway changes after orthodontic treatment with premolar extraction and maximum anchorage in adults are mainly morphological changes with anteroposterior dimension compressed in airway cross sections, rather than a decrease in size. PMID:26588714

  13. Experimental and Numerical Analysis of a DECSMAR Structure’s Deployment and Deployed Performance

    DTIC Science & Technology

    2007-04-01

    compromise of deployed performance due to the hinge cross- section, Nitinol SMA wires can be embedded in the composite lay-up across the reduced...100 !m 0˚ 2 (two, 1.47 mm width wires positioned along longitudinal edges) Nitinol 305 !m N/A 3 IM7/977-2 100 !m 0˚ batten transition 1 IM7

  14. Standardized quantitative measurements of wrist cartilage in healthy humans using 3T magnetic resonance imaging

    PubMed Central

    Zink, Jean-Vincent; Souteyrand, Philippe; Guis, Sandrine; Chagnaud, Christophe; Fur, Yann Le; Militianu, Daniela; Mattei, Jean-Pierre; Rozenbaum, Michael; Rosner, Itzhak; Guye, Maxime; Bernard, Monique; Bendahan, David

    2015-01-01

    AIM: To quantify the wrist cartilage cross-sectional area in humans from a 3D magnetic resonance imaging (MRI) dataset and to assess the corresponding reproducibility. METHODS: The study was conducted in 14 healthy volunteers (6 females and 8 males) between 30 and 58 years old and devoid of articular pain. Subjects were asked to lie down in the supine position with the right hand positioned above the pelvic region on top of a home-built rigid platform attached to the scanner bed. The wrist was wrapped with a flexible surface coil. MRI investigations were performed at 3T (Verio-Siemens) using volume interpolated breath hold examination (VIBE) and dual echo steady state (DESS) MRI sequences. Cartilage cross sectional area (CSA) was measured on a slice of interest selected from a 3D dataset of the entire carpus and metacarpal-phalangeal areas on the basis of anatomical criteria using conventional image processing radiology software. Cartilage cross-sectional areas between opposite bones in the carpal region were manually selected and quantified using a thresholding method. RESULTS: Cartilage CSA measurements performed on a selected predefined slice were 292.4 ± 39 mm2 using the VIBE sequence and slightly lower, 270.4 ± 50.6 mm2, with the DESS sequence. The inter (14.1%) and intra (2.4%) subject variability was similar for both MRI methods. The coefficients of variation computed for the repeated measurements were also comparable for the VIBE (2.4%) and the DESS (4.8%) sequences. The carpus length averaged over the group was 37.5 ± 2.8 mm with a 7.45% between-subjects coefficient of variation. Of note, wrist cartilage CSA measured with either the VIBE or the DESS sequences was linearly related to the carpal bone length. The variability between subjects was significantly reduced to 8.4% when the CSA was normalized with respect to the carpal bone length. CONCLUSION: The ratio between wrist cartilage CSA and carpal bone length is a highly reproducible standardized measurement which normalizes the natural diversity between individuals. PMID:26396941

  15. Flat midsubstance of the anterior cruciate ligament with tibial "C"-shaped insertion site.

    PubMed

    Siebold, Rainer; Schuhmacher, Peter; Fernandez, Francis; Śmigielski, Robert; Fink, Christian; Brehmer, Axel; Kirsch, Joachim

    2015-11-01

    This anatomical cadaver study was performed to investigate the flat appearance of the midsubstance shape of the anterior cruciate ligament (ACL) and its tibial "C"-shaped insertion site. The ACL midsubstance and the tibial ACL insertion were dissected in 20 cadaveric knees (n = 6 fresh frozen and n = 14 paraffined). Magnifying spectacles were used for all dissections. Morphometric measurements were performed using callipers and on digital photographs. In all specimens, the midsubstance of the ACL was flat with a mean width of 9.9 mm, thickness of 3.9 mm and cross-sectional area of 38.7 mm(2). The "direct" "C"-shaped tibial insertion runs from along the medial tibial spine to the anterior aspect of the lateral meniscus. The mean width (length) of the "C" was 12.6 mm, its thickness 3.3 mm and area 31.4 mm(2). The centre of the "C" was the bony insertion of the anterior root of the lateral meniscus overlayed by fat and crossed by the ACL. No posterolateral (PL) inserting ACL fibres were found. Together with the larger "indirect" part (area 79.6 mm(2)), the "direct" one formed a "duck-foot"-shaped footprint. The tibial ACL midsubstance and tibial "C"-shaped insertion are flat and are resembling a "ribbon". The centre of the "C" is the bony insertion of the anterior root of the lateral meniscus. There are no central or PL inserting ACL fibres. Anatomical ACL reconstruction may therefore require a flat graft and a "C"-shaped tibial footprint reconstruction with an anteromedial bone tunnel for single bundle and an additional posteromedial bone tunnel for double bundle.

  16. Impact of endobronchial coiling on segmental bronchial lumen in treated and untreated lung lobes: Correlation with changes in lung volume, clinical and pulmonary function tests.

    PubMed

    Kloth, C; Thaiss, W M; Hetzel, J; Ditt, H; Grosse, U; Nikolaou, K; Horger, M

    2016-07-01

    To assess the impact of endobronchial coiling on the segment bronchus cross-sectional area and volumes in patients with lung emphysema using quantitative chest-CT measurements. Thirty patients (female = 15; median age = 65.36 years) received chest-CT before and after endobronchial coiling for lung volume reduction (LVR) between January 2010 and December 2014. Thin-slice (0.6 mm) non-enhanced image data sets were acquired both at end-inspiration and end-expiration using helical technique and 120 kV/100-150 mAs. Clinical response was defined as an increase in the walking distance (Six-minute walk test; 6MWT) after LVR-therapy. Additionally, pulmonary function test (PFT) measurements were used for clinical correlation. In the treated segmental bronchia, the cross-sectional lumen area showed significant reduction (p < 0.05) in inspiration and tendency towards enlargement in expiration (p > 0.05). In the ipsilateral lobes, the lumina showed no significant changes. In the contralateral lung, we found tendency towards increased cross-sectional area in inspiration (p = 0.06). Volumes of the treated segments correlated with the treated segmental bronchial lumina in expiration (r = 0.80, p < 0.001). Clinical correlation with changes in 6MWT/PFT showed a significant decrease of the inspiratory volume of the treated lobe in responders only. Endobronchial coiling causes significant decrease in the cross-sectional area of treated segment bronchi in inspiration and a slight increase in expiration accompanied by a volume reduction. • Endobronchial coiling has indirect impact on cross-sectional area of treated segment bronchi • Volume changes of treated lobes correlate with changes in bronchial cross-sectional area • Coil-induced effects reflect their stabilizing and stiffening impact on lung parenchyma • Endobronchial coiling reduces bronchial collapsing compensating the loss of elasticity.

  17. Neuromuscular organization of avian flight muscle: architecture of single muscle fibres in muscle units of the pectoralis (pars thoracicus) of pigeon (Columba livia)

    PubMed Central

    Sokoloff, A. J.

    1999-01-01

    The M. pectoralis (pars thoracicus) of pigeons (Columba livia) is comprised of short muscle fibres that do not extend from muscle origin to insertion but overlap 'in-series'. Individual pectoralis motor units are limited in territory to a portion of muscle length and are comprised of either fast twitch, oxidative and glycolytic fibres (FOG) or fast twitch and glycolytic fibres (FG). FOG fibres make up 88 to 90% of the total muscle population and have a mean diameter one-half of that of the relatively large FG fibres. Here we report on the organization of individual fibres identified in six muscle units depleted of glycogen, three comprised of FOG fibres and three comprised of FG fibres. For each motor unit, fibre counts revealed unequal numbers of depleted fibres in different unit cross-sections. We traced individual fibres in one unit comprised of FOG fibres and a second comprised of FG fibres. Six fibres from a FOG unit (total length 15.45 mm) ranged from 10.11 to 11.82 mm in length and averaged (± s.d.) 10.74 ± 0.79 mm. All originated bluntly (en mass) from a fascicle near the proximal end of the muscle unit and all terminated intramuscularly. Five of these ended in a taper and one ended bluntly. Fibres coursed on average for 70% of the muscle unit length. Six fibres from a FG unit (total length 34.76 mm) ranged from 8.97 to 18.38 mm in length and averaged 15.32 ± 3.75 mm. All originated bluntly and terminated intramuscularly; one of these ended in a taper and five ended bluntly. Fibres coursed on average for 44% of the muscle unit length. Because fibres of individual muscle units do not extend the whole muscle unit territory, the effective cross-sectional area changes along the motor unit length. These non-uniformities in the distribution of fibres within a muscle unit emphasize that the functional interactions within and between motor units are complex.

  18. Multimedia manuscript. Heller myotomy and intraluminal fundoplication: a NOTES technique.

    PubMed

    Perretta, Silvana; Dallemagne, Bernard; Allemann, Pierre; Alleman, Pierre; Marescaux, Jacques

    2010-11-01

    It is generally accepted that the most effective treatment of achalasia is a surgical myotomy. Nevertheless, if a myotomy alone is performed, reflux may occur in up to 30% of patients. The aim of this study was to explore a transoral incisionless stepwise approach to both esophageal Heller myotomy and fundoplication. The first step consisted of creating the esophageal myotomy. Under general anesthesia, with the pig supine, endoscopy was performed to assess the location of the esophagogastric junction (EGJ). The mucosa on the right posterolateral esophageal wall was cut with the needle-knife 15 cm above the lower esophageal sphincter (LES) and then dilated with blunt dissection to introduce the scope. A submucosal tunnel was created distally with CO(2) and blunt dissection. Once the gastroesophageal junction (GEJ) and the clasp fibers were identified, the muscular layer was cut. The scope was withdrawn into the lumen and the mucosal flap was sealed with endoscopic clips. The adequacy of the myotomy was evaluated using pre- and postoperative manometry and by comparing the EGJ distensibility before, during, and after the division of the esophageal muscular fibers using the functional lumen imaging probe, EndoFLIP®. The second step, consisted of building a transoral incisionless fundoplication 4 weeks postoperatively using the EsophyX™. Both Heller myotomy and endoscopic fundoplication were accomplished successfully with no injury to the esophageal mucosa. Postoperative manometry demonstrated a 50% loss in mean LES pressure (mean preoperative LES pressure = 22.2 mmHg; mean postoperative LES pressure = 10 mmHg, P < 0.005). The EndoFLIP® showed a preoperative minimal diameter of 6 mm with a cross-sectional area of 28 mm(2). Postoperatively, the junction was more compliant (minimal diameter = 15 mm; cross-sectional area = 177 mm(2)), with the main improvement in distensibility occurring when the clasps fibers were removed. A stepwise transoral incisionless approach to esophageal Heller myotomy and partial fundoplication is feasible and effective in the porcine model. A distensibility test such as the EndoFLIP® may provide better information on the opening and closing dynamics of the EGJ, rather than just relying on the sphincter tonic state as measured by manometry.

  19. An experimental investigation of liquid methane convection and boiling in rocket engine cooling channels

    NASA Astrophysics Data System (ADS)

    Trujillo, Abraham Gerardo

    In the past decades, interest in developing hydrocarbon-fueled rocket engines for deep spaceflight missions has continued to grow. In particular, liquid methane (LCH4) has been of interest due to the weight efficiency, storage, and handling advantages it offers over several currently used propellants. Deep space exploration requires reusable, long life rocket engines. Due to the high temperatures reached during combustion, the life of an engine is significantly impacted by the cooling system's efficiency. Regenerative (regen) cooling is presented as a viable alternative to common cooling methods such as film and dump cooling since it provides improved engine efficiency. Due to limited availability of experimental sub-critical liquid methane cooling data for regen engine design, there has been an interest in studying the heat transfer characteristics of the propellant. For this reason, recent experimental studies at the Center for Space Exploration Technology Research (cSETR) at the University of Texas at El Paso (UTEP) have focused on investigating the heat transfer characteristics of sub-critical CH4 flowing through sub-scale cooling channels. To conduct the experiments, the csETR developed a High Heat Flux Test Facility (HHFTF) where all the channels are heated using a conduction-based thermal concentrator. In this study, two smooth channels with cross sectional geometries of 1.8 mm x 4.1 mm and 3.2 mm x 3.2 mm were tested. In addition, three roughened channels all with a 3.2 mm x 3.2 mm square cross section were also tested. For the rectangular smooth channel, Reynolds numbers ranged between 68,000 and 131,000, while the Nusselt numbers were between 40 and 325. For the rough channels, Reynolds numbers ranged from 82,000 to 131,000, and Nusselt numbers were between 65 and 810. Sub-cooled film-boiling phenomena were confirmed for all the channels presented in this work. Film-boiling onset at Critical Heat Flux (CHF) was correlated to a Boiling Number (Bo) of approximately 0.1 for all channels. Convective Nusselt number follows predicted trends for Reynolds number with a wall temperature correction for both the boiling and non-boiling regimes.

  20. Mid-second trimester measurement of fetal nasal bone length in the Japanese population.

    PubMed

    Kanagawa, Takeshi; Fukuda, Hirotsugu; Kinugasa, Yukiko; Son, Mihyon; Shimoya, Koichiro; Murata, Yuji; Yokoyama, Takuhei; Hashimoto, Hiroyuki; Isaka, Shigeyuki; Nagamatsu, Masaaki

    2006-08-01

    We carried out a preliminary study to compare the nasal bone length (NBL) and biparietal diameter/NBL (BPD/NBL) ratio between the Japanese and white populations. Three hundred and fifty nine (359) singleton fetuses of healthy Japanese couples were examined from June 2004 to October 2005. NBL was measured by the strict midsagittal section. The reference range of NBL was established from cross-sectional data between 15 and 25 weeks' gestation. The success rate of obtaining reliable NBL was 93% (333/356). There were 330 fetuses (93%) available for constructing a reference range from the population. The median NBL increased from 3.2 mm at 15 weeks' to 7.6 mm at 25 weeks' gestation. The median of BPD/NBL ratio was 9.01. We demonstrated that NBL was significantly shorter and BPD/NBL was significantly greater in the Japanese population than those in the white and black populations.

  1. Influence of cross-sectional design and dimension on mechanical behavior of nickel-titanium instruments under torsion and bending: a numerical analysis.

    PubMed

    Zhang, En-Wei; Cheung, Gary S P; Zheng, Yu-Feng

    2010-08-01

    The aim of this study was to examine the influence of the cross-sectional configuration and dimensions (size and taper) on the torsional and bending behavior of nickel-titanium rotary instruments, taking into account the nonlinear mechanical properties of material. Ten cross-sectional configurations, square, triangular, U-type, S-type (large and small), convex-triangle, and 4 proprietary ones (Mani NRT and RT2, Quantec, and Mtwo), were analyzed under torsion or bending by using a 3-dimensional finite element method. The von Mises stresses were correlated with the critical values for various phases of the nickel-titanium material. Different loading conditions led to unequal patterns of stress distribution. Increasing the applied torque or bending angle resulted in a rise in the corresponding stresses in the instrument. Favorable stress distribution without dangerous stress concentration was observed if the material was undergoing superelastic transformation at that applied load. The ultimate strength of the material was not exceeded when the instrument was bent up to a 50-degree curvature. On the other hand, when a torsional moment of greater than 1.0 N*mm was applied, the maximum stresses developed in some designs would exceed the ultimate strength of the material. Little variation in the von Mises stresses was observed for instruments of different nominal sizes and tapers on bending to similar extent. The cross-sectional design has a greater impact than taper or size of the instrument on the stresses developed in the instrument under either torsion or bending. Certain cross-sectional configurations are prone to fracture by excess torsional stresses. Copyright 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. Abdominal aortic aneurysms: pre- and post-procedural imaging.

    PubMed

    Hallett, Richard L; Ullery, Brant W; Fleischmann, Dominik

    2018-05-01

    Abdominal aortic aneurysm (AAA) is a relatively common, potentially life-threatening disorder. Rupture of AAA is potentially catastrophic with high mortality. Intervention for AAA is indicated when the aneurysm reaches 5.0-5.5 cm or more, when symptomatic, or when increasing in size > 10 mm/year. AAA can be accurately assessed by cross-sectional imaging including computed tomography angiography and magnetic resonance angiography. Current options for intervention in AAA patients include open surgery and endovascular aneurysm repair (EVAR), with EVAR becoming more prevalent over time. Cross-sectional imaging plays a crucial role in AAA surveillance, pre-procedural assessment, and post-EVAR management. This paper will discuss the current role of imaging in the assessment of AAA patients prior to intervention, in evaluation of procedural complications, and in long-term follow-up of EVAR patients.

  3. Boundary effects on forced drainage through aqueous foam

    NASA Astrophysics Data System (ADS)

    Brannigan, G.; de Alcantara Bonfim, O. F.

    2001-03-01

    The flow of liquid through foam confined in vertical tubes was investigated by measuring the velocity vf of the liquid front forced down by gravity for various flow rates Q. The power law relating the velocity to flow rate of the incoming liquid (v_f ~ Q^α) was observed for tubes of various cross-sectional areas, A. The exponent α was found to vary linearly with the reciprocal of the area: α= 0.325 + 13.7 mm^2/A . This further supports the node-dominated foam drainage model, which predicts α= 1/3 in the limit of infinite cross-sectional area. This relation appears to be independent of bubble size, suggesting that using smaller foam bubbles may not alleviate boundary effects. The results of these experiments also partially explain the discrepancies in measurements of α reported in previous works.

  4. Studies on scintillating fiber response

    NASA Astrophysics Data System (ADS)

    Albers, D.; Bisplinghoff, J.; Bollmann, R.; Büßer, K.; Cloth, P.; Diehl, O.; Dohrmann, F.; Drüke, V.; Engelhardt, H. P.; Ernst, J.; Eversheim, P. D.; Filges, D.; Gasthuber, M.; Gebel, R.; Greiff, J.; Groß, A.; Groß-Hardt, R.; Heine, A.; Heider, S.; Hinterberger, F.; Igelbrink, M.; Jahn, R.; Jeske, M.; Langkau, R.; Lindlein, J.; Maier, R.; Maschuw, R.; Mayer-Kuckuk, T.; Mertler, G.; Metsch, B.; Mosel, F.; Müller, M.; Münstermann, M.; Paetz gen. Schieck, H.; Petry, H. R.; Prasuhn, D.; Rohdjeß, H.; Rosendaal, D.; Roß, U.; von Rossen, P.; Scheid, H.; Schirm, N.; Schulz-Rojahn, M.; Schwandt, F.; Scobel, W.; Steeg, B.; Sterzenbach, G.; Trelle, H. J.; Wellinghausen, A.; Wiedmann, W.; Woller, K.; Ziegler, R.

    1996-02-01

    Scintillating fibers of type Bicron BCF-12 with 2 × 2 mm 2 cross section, up to 600 mm length, and PMMA cladding have been tested, in conjunction with the multi-channel photomultiplier Hamamatsu R 4760, with minimum ionizing electrons. The impact of cladding, extramural absorbers and/or wrapping on the light attenuation and photoelectron yield is studied in detail. Fibers have been circularly bent with radii of 171 mm and arranged in two layers to bundles forming granulated scintillator rings. Their performance in the EDDA experiment at COSY for detection of high energy protons revealed typically more than 9 (6) photoelectrons per fiber from bundles with (without) mirror on the rear side, guaranteeing detection efficiencies >99% and full compatibility with corresponding solid scintillator rings. The time resolution of 3.4 ns FWHM per fiber read out is essentially due to the R 4760.

  5. Comparison of PA imaging by narrow beam scanning and one-shot broad beam excitation

    NASA Astrophysics Data System (ADS)

    Xia, Jinjun; Wei, Chen-Wei; Huang, Lingyun; Pelivanov, I. M.; O'Donnell, Matthew

    2011-03-01

    Current systems designed for deep photoacoustic (PA) imaging typically use a low repetition rate, high power pulsed laser to provide a ns-scale pulse illuminating a large tissue volume. Acoustic signals recorded on each laser firing can be used to reconstruct a complete 2-D (3-D) image of sources of heat release within that region. Using broad-beam excitation, the maximum frame rate of the imaging system is restricted by the pulse repetition rate of the laser. An alternate illumination approach is proposed based on fast scanning by a low energy (~ 1 mJ) high repetition rate (up to a few kHz) narrow laser beam (~1 mm) along the tissue surface over a region of interest. A final PA image is produced from the summation of individual PA images reconstructed at each laser beam position. This concept can take advantage of high repetition rate fiber lasers to create PA images with much higher frame rates than current systems, enabling true real-time integration of photoacoustics with ultrasound imaging. As an initial proof of concept, we compare conventional broad beam illumination to a scanned beam approach in a simple model system. Two transparent teflon tubes with diameters of 1.6 mm and 0.8 mm were filled with ink having an absorption coefficient of 5 cm-1. These tubes were buried inside chicken breast tissue acting as an optical scattering medium. They were separated by 3 mm or 10 mm to test spatial and contrast resolution for the two scan formats. The excitation wavelength was 700 nm. The excitation source is a traditional OPO pumped by a Q-switched Nd:YAG laser with doubler. Photoacoustic images were reconstructed using signals from a small, scanned PVDF transducer acting as an acoustic array. Two different illumination schemes were compared: one was 15 mm x 10 mm in cross section and acted as the broad beam; the other was 5 mm x 2 mm in cross section (15 times smaller than the broad beam case) and was scanned over an area equivalent to broad beam illumination. Multiple images obtained during narrow beam scanning were added together to form one PA image equivalent to the single-shot broad beam one. Results of the phantom study indicate that PA images formed by narrow beam scanning excitation can be equivalent to one shot broad beam illumination in signal to noise ratio and spatial resolution. Future studies will focus on high repetition-rate laser sources and scan formats appropriate for real-time, integrated deep photoacoustic/ultrasonic imaging.

  6. Estimation of uncertainty for contour method residual stress measurements

    DOE PAGES

    Olson, Mitchell D.; DeWald, Adrian T.; Prime, Michael B.; ...

    2014-12-03

    This paper describes a methodology for the estimation of measurement uncertainty for the contour method, where the contour method is an experimental technique for measuring a two-dimensional map of residual stress over a plane. Random error sources including the error arising from noise in displacement measurements and the smoothing of the displacement surfaces are accounted for in the uncertainty analysis. The output is a two-dimensional, spatially varying uncertainty estimate such that every point on the cross-section where residual stress is determined has a corresponding uncertainty value. Both numerical and physical experiments are reported, which are used to support the usefulnessmore » of the proposed uncertainty estimator. The uncertainty estimator shows the contour method to have larger uncertainty near the perimeter of the measurement plane. For the experiments, which were performed on a quenched aluminum bar with a cross section of 51 × 76 mm, the estimated uncertainty was approximately 5 MPa (σ/E = 7 · 10⁻⁵) over the majority of the cross-section, with localized areas of higher uncertainty, up to 10 MPa (σ/E = 14 · 10⁻⁵).« less

  7. Air Gaps, Size Effect, and Corner-Turning in Ambient LX-17

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Souers, P C; Hernandez, A; Cabacungen, C

    2007-05-30

    Various ambient measurements are presented for LX-17. The size (diameter) effect has been measured with copper and Lucite confinement, where the failure radii are 4.0 and 6.5 mm, respectively. The air well corner-turn has been measured with an LX-07 booster, and the dead-zone results are comparable to the previous TATB-boosted work. Four double cylinders have been fired, and dead zones appear in all cases. The steel-backed samples are faster than the Lucite-backed samples by 0.6 {micro}s. Bare LX-07 and LX-17 of 12.7 mm-radius were fired with air gaps. Long acceptor regions were used to truly determine if detonation occurred ormore » not. The LX-07 crossed at 10 mm with a slight time delay. Steady state LX-17 crossed at 3.5 mm gap but failed to cross at 4.0 mm. LX-17 with a 12.7 mm run after the booster crossed a 1.5 mm gap but failed to cross 2.5 mm. Timing delays were measured where the detonation crossed the gaps. The Tarantula model is introduced as embedded in the Linked Cheetah V4.0 reactive flow code at 4 zones/mm. Tarantula has four pressure regions: off, initiation, failure and detonation. A report card of 25 tests run with the same settings on LX-17 is shown, possibly the most extensive simultaneous calibration yet tried with an explosive. The physical basis of some of the input parameters is considered.« less

  8. Mesenchymal Stem Cell Therapy for Nerve Regeneration and Immunomodulation after Composite Tissue Allotransplantation

    DTIC Science & Technology

    2012-08-01

    early rejection of the grafts, there was no significant functional recovery noted on electromyography or Catwalk gait analysis. However, in vitro...Figure 10: Light Microscopic Image (100X, stained with Toluidine Blue): Nerve Cross Section 5-8 mm distal to anastomosis site. Representative... images from (A) Systemic MSC therapy, (B) Local MSC therapy and (c) No treatment Control Figure 11: Sciatic Nerve Transection and Repair (6

  9. Safety screw fixation technique in a case of coracoid base fracture with acromioclavicular dislocation and coracoid base cross-sectional size data from a computed axial tomography study.

    PubMed

    Kawasaki, Yoshiteru; Hirano, Tetsuya; Miyatake, Katsutoshi; Fujii, Koji; Takeda, Yoshitsugu

    2014-07-01

    Coracoid base fracture accompanied by acromioclavicular joint dislocation with intact coracoclavicular ligaments is a rare injury. Generally, an open reduction with screw fixation is the first treatment choice, as it protects the important structures around the coracoid process. This report presents a new technique of screw fixation for coracoid base fracture and provides anatomic information on cross-sectional size of the coracoid base obtained by computed tomography (CT). An axial image of the coracoid base was visualized over the neck of the scapula, and a guidewire was inserted into this circle under fluoroscopic guidance. The wire was inserted easily into the neck of scapula across the coracoid base fracture with imaging in only 1 plane. In addition, 25 measurements of the coracoid base were made in 25 subjects on axial CT images. Average length of the long and short axes at the thinnest part of the coracoid base was 13.9 ± 2.0 mm (range 10.6-17.0) and 10.5 ± 2.2 mm (6.6-15.1), respectively. This new screw fixation technique and measurement data on the coracoid base may be beneficial for safety screw fixation of coracoid base fracture.

  10. Determination of integral cross sections of 3H in Al foils monitors irradiated by protons with energies ranging from 40 to 2600 MeV

    NASA Astrophysics Data System (ADS)

    Titarenko, Yu. E.; Batyaev, V. F.; Chauzova, M. V.; Chauzova, M. V.; Kashirin, I. A.; Malinovskiy, S. V.; Pavlov, K. V.; Rogov, V. I.; Titarenko, A. Yu.; Zhivun, V. M.; Mashnik, S. G.; Stankovskiy, A. Yu.

    2016-05-01

    The results of 3H production in Al foil monitors (˜ 59 mg/cm2 thickness) are presented. These foils have been irradiated in 15×15 mm polyethylene bags of ˜ 14 mg/cm2 thickness together with foils of Cr (˜ 395 mg/cm2 thickness) and 56Fe (˜ 332 mg/cm2 thickness) by protons of different energies in a range of 0.04 - 2.6 GeV. The diameters of all the foils were 10.5 mm. The irradiations were carried out at the ITEP accelerator U-10 under the ISTC Project # 3266 in 2006-2009. 3H has been extracted from Al foils using an A307 Sample Oxidizer. An ultra low level liquid scintillation spectrometer Quantulus1220 was used to measure the 3H β-spectra and the SpectraDec software package was applied for spectra processing, deconvolution and 3H activity determination. The values of the Al (p, x)3H reaction cross sections obtained in these experiments are compared with data measured at other labs and with results of simulations by the MCNP6 radiation transport code using the CEM03.03 event generator.

  11. Determination of integral cross sections of 3 H in Al foils monitors irradiated by protons with energies ranging from 40 to 2600 MeV

    DOE PAGES

    Titarenko, Yu. E.; Batyaev, V. F.; Chauzova, M. V.; ...

    2016-01-01

    Our results of 3H production in Al foil monitors (~ 59 mg/cm 2 thickness) are presented. We irradiated these foils in 15×15 mm polyethylene bags of ~ 14 mg/cm 2 thickness together with foils of Cr (~ 395 mg/cm 2 thickness) and 56Fe (~ 332 mg/cm 2 thickness) by protons of different energies in a range of 0.04 – 2.6 GeV. The diameters of all the foils were 10.5 mm. The irradiations were carried out at the ITEP accelerator U–10 under the ISTC Project # 3266 in 2006–2009. 3H has been extracted from Al foils using an A307 Sample Oxidizer.more » We then used an ultra low level liquid scintillation spectrometer Quantulus1220 to measure the 3H β–spectra and the SpectraDec software package was applied for spectra processing, deconvolution and 3H activity determination. The values of the Al (p, x) 3H reaction cross sections obtained in these experiments are compared with data measured at other labs and with results of simulations by the MCNP6 radiation transport code using the CEM03.03 event generator.« less

  12. Observations of movement dynamics of flying insects using high resolution lidar.

    PubMed

    Kirkeby, Carsten; Wellenreuther, Maren; Brydegaard, Mikkel

    2016-07-04

    Insects are fundamental to ecosystem functioning and biodiversity, yet the study of insect movement, dispersal and activity patterns remains a challenge. Here we present results from a novel high resolution laser-radar (lidar) system for quantifying flying insect abundance recorded during one summer night in Sweden. We compare lidar recordings with data from a light trap deployed alongside the lidar. A total of 22808 insect were recorded, and the relative temporal quantities measured matched the quantities recorded with the light trap within a radius of 5 m. Lidar records showed that small insects (wing size <2.5 mm(2) in cross-section) moved across the field and clustered near the light trap around 22:00 local time, while larger insects (wing size >2.5 mm(2) in cross-section) were most abundant near the lidar beam before 22:00 and then moved towards the light trap between 22:00 and 23:30. We could distinguish three insect clusters based on morphology and found that two contained insects predominantly recorded above the field in the evening, whereas the third was formed by insects near the forest at around 21:30. Together our results demonstrate the capability of lidar for distinguishing different types of insect during flight and quantifying their movements.

  13. Tensile Properties of the Deep Transverse Metatarsal Ligament in Hallux Valgus: A CONSORT-Compliant Article.

    PubMed

    Abdalbary, Sahar Ahmed; Elshaarawy, Ehab A A; Khalid, Bahaa E A

    2016-02-01

    The deep transverse metatarsal ligament (DTML) connects the neighboring2 metatarsal heads and is one of the stabilizers connecting the lateral sesamoid and second metatarsal head. In this study, we aimed to determine the tensile properties of the DTML in normal specimens and to compare these results with hallux valgus specimens. We hypothesized that the tensile properties of the DTML would be different between the 2 groups of specimens.The DTML in the first interspace was dissected from 12 fresh frozen human cadaveric specimens. Six cadavers had bilateral hallux valgus and the other 6 cadavers had normal feet. The initial length (L0) and cross-sectional area (A0) of the DTML were measured using a digital caliper, and tensile tests with load failure were performed using a material testing machine.There were significant between-groups differences in the initial length (L0) P = 0.009 and cross-sectional area (A0) of the DTML P = 0.007. There were also significant between-groups differences for maximum force (N) P = 0.004, maximum distance (mm) P = 0.005, maximum stress (N/mm) P = 0.003, and maximum strain (%) P = 0.006.The DTML is an anatomical structure for which the tensile properties differ in hallux valgus.

  14. Laser cutting of bone tissue under bulk water with a pulsed ps-laser at 532 nm.

    PubMed

    Tulea, Cristian-Alexander; Caron, Jan; Gehlich, Nils; Lenenbach, Achim; Noll, Reinhard; Loosen, Peter

    2015-10-01

    Hard-tissue ablation was already investigated for a broad variety of pulsed laser systems, which cover almost the entire range of available wavelengths and pulse parameters. Most effective in hard-tissue ablation are Er:YAG and CO2 lasers, both utilizing the effect of absorption of infrared wavelengths by water and so-called explosive vaporization, when a thin water film or water–air spray is supplied. The typical flow rates and the water layer thicknesses are too low for surgical applications where bleeding occurs and wound flushing is necessary. We studied a 20 W ps-laser with 532 nm wavelength and a pulse energy of 1 mJ to effectively ablate bones that are submerged 14 mm under water. For these laser parameters, the plasma-mediated ablation mechanism is dominant. Simulations based on the blow-off model predict the cut depth and cross-sectional shape of the incision. The model is modified considering the cross section of the Gaussian beam, the incident angle, and reflections. The ablation rate amounts to 0.2  mm3/s, corresponding to an increase by at least 50% of the highest values published so far for ultrashort laser ablation of hard tissue.

  15. Observations of movement dynamics of flying insects using high resolution lidar

    PubMed Central

    Kirkeby, Carsten; Wellenreuther, Maren; Brydegaard, Mikkel

    2016-01-01

    Insects are fundamental to ecosystem functioning and biodiversity, yet the study of insect movement, dispersal and activity patterns remains a challenge. Here we present results from a novel high resolution laser-radar (lidar) system for quantifying flying insect abundance recorded during one summer night in Sweden. We compare lidar recordings with data from a light trap deployed alongside the lidar. A total of 22808 insect were recorded, and the relative temporal quantities measured matched the quantities recorded with the light trap within a radius of 5 m. Lidar records showed that small insects (wing size <2.5 mm2 in cross-section) moved across the field and clustered near the light trap around 22:00 local time, while larger insects (wing size >2.5 mm2 in cross-section) were most abundant near the lidar beam before 22:00 and then moved towards the light trap between 22:00 and 23:30. We could distinguish three insect clusters based on morphology and found that two contained insects predominantly recorded above the field in the evening, whereas the third was formed by insects near the forest at around 21:30. Together our results demonstrate the capability of lidar for distinguishing different types of insect during flight and quantifying their movements. PMID:27375089

  16. Diode laser prostatectomy (VLAP): initial canine evaluation

    NASA Astrophysics Data System (ADS)

    Kopchok, George E.; Verbin, Chris; Ayres, Bruce; Peng, Shi-Kaung; White, Rodney A.

    1995-05-01

    This study evaluated the acute and chronic effects of diode laser (960 nm) prostatectomy using a Prolase II fiber in a canine model (n equals 5). The laser fiber consists of a 1000 um quartz fiber which reflects a cone of laser energy, at 45 degree(s) to the axis of the fiber, into the prostatic urethra (Visual Laser Ablation of Prostate). Perineal access was used to guide a 15.5 Fr cystoscope to the level of the prostate. Under visual guidance and continual saline irrigation, 60 watts of laser power was delivered for 60 seconds at 3, 9, and 12 o'clock and 30 seconds at the 6 o'clock (posterior) positions for a total energy fluence of 12,600 J. One prostate received an additional 60 second exposure at 3 and 9 o'clock for a total fluence of 19,800 J. The prostates were evaluated at one day (n equals 1) and 8 weeks (n equals 4). The histopathology of laser effects at one day show areas of necrosis with loss of glandular structures and stromal edema. Surrounding this area was a zone of degenerative glandular structures extending up to 17.5 mm (cross sectional diameter). The histopathology of the 8 week laser treated animals demonstrated dilated prostatic urethras with maximum cross- sectional diameter of 23.4 mm (mean equals 18.5 +/- 3.9 mm). This study demonstrates the effectiveness of diode laser energy for prostatic tissue coagulation and eventual sloughing. The results also demonstrate the safety of diode laser energy, with similar tissue response as seen with Nd:YAG laser, for laser prostatectomy.

  17. The association of remotely-sensed outdoor temperature with blood pressure levels in REGARDS: a cross-sectional study of a large, national cohort of African-American and white participants

    PubMed Central

    2011-01-01

    Background Evidence is mounting regarding the clinically significant effect of temperature on blood pressure. Methods In this cross-sectional study the authors obtained minimum and maximum temperatures and their respective previous week variances at the geographic locations of the self-reported residences of 26,018 participants from a national cohort of blacks and whites, aged 45+. Linear regression of data from 20,623 participants was used in final multivariable models to determine if these temperature measures were associated with levels of systolic or diastolic blood pressure, and whether these relations were modified by stroke-risk region, race, education, income, sex hypertensive medication status, or age. Results After adjustment for confounders, same-day maximum temperatures 20°F lower had significant associations with 1.4 mmHg (95% CI: 1.0, 1.9) higher systolic and 0.5 mmHg (95% CI: 0.3, 0.8) higher diastolic blood pressures. Same-day minimum temperatures 20°F lower had a significant association with 0.7 mmHg (95% CI: 0.3, 1.0) higher systolic blood pressures but no significant association with diastolic blood pressure differences. Maximum and minimum previous-week temperature variabilities showed significant but weak relationships with blood pressures. Parameter estimates showed effect modification of negligible magnitude. Conclusions This study found significant associations between outdoor temperature and blood pressure levels, which remained after adjustment for various confounders including season. This relationship showed negligible effect modification. PMID:21247466

  18. Association of N-Terminal Pro B-Type Natriuretic Peptide With Blood Pressure and Pulse Pressure in Elderly People - A Cross-Sectional Population Study.

    PubMed

    Sasaki, Nobuo; Yamamoto, Hideya; Ozono, Ryoji; Fujiwara, Saeko; Kihara, Yasuki

    2018-05-23

    N-Terminal pro B-type natriuretic peptide (NT-proBNP) is widely used as a marker of ventricular dysfunction. However, data regarding the association of NT-proBNP with blood pressure (BP) and pulse pressure (PP) in the elderly population are limited.Methods and Results:The present cross-sectional study involved 6,529 participants, aged ≥70 years, without cardiovascular disease (CVD), who underwent general health examinations. Serum NT-proBNP concentrations were determined, with high NT-proBNP concentrations defined as those ≥125 pg/mL. Subjects were divided into five groups based on PP (<50, ≥50 to <60, ≥60 to <70, ≥70 to <80, and ≥80 mmHg). NT-proBNP was positively associated with systolic BP, whereas a U-shaped association was found between diastolic BP and NT-proBNP. The odds ratios for high NT-proBNP concentrations in the PP ≥80 and ≥70 to <80 mmHg groups (OR 1.83 [P<0.001] and 1.40 [P<0.005], respectively) were significantly higher than in the PP <50 mmHg group. All data were adjusted for age, sex, body mass index, hemoglobin concentration, serum creatinine, pulse rate, smoking, alcohol intake, and antihypertensive medication intake, and the presence of diabetes and dyslipidemia. The results suggest that NT-proBNP concentrations may be a marker of not only ventricular dysfunction, but also arterial stiffness in the elderly population without CVD.

  19. Low molecular weight dextran provides similar optical coherence tomography coronary imaging compared to radiographic contrast media.

    PubMed

    Frick, Kyle; Michael, Tesfaldet T; Alomar, Mohammed; Mohammed, Atif; Rangan, Bavana V; Abdullah, Shuaib; Grodin, Jerrold; Hastings, Jeffrey L; Banerjee, Subhash; Brilakis, Emmanouil S

    2014-11-01

    Optical coherence tomography (OCT) coronary imaging requires displacement of red blood cells from the vessel lumen. This is usually accomplished using radiographic contrast. Low molecular weight dextran has low cost and is safe in low volumes. In the present study, we compared dextran with contrast for coronary OCT imaging. Fifty-one vessels in 26 patients were sequentially imaged using manual injection of radiographic contrast (iodixanol) and dextran. OCT images were analyzed at 1 mm intervals to determine the image clarity (defined as a visible lumen border > 270°) and to measure the lumen area and lumen diameter. To correct for the refractive index of dextran, the dextran area measurements were multiplied by 1.117 and the dextran length measurements were multiplied by 1.057. A total of 3,418 cross-sections (1,709 with contrast and 1,709 with dextran) were analyzed. There were no complications related to OCT imaging or to contrast or dextran administration. Clear image segments were observed in 97.0% vs. 96.7% of the cross-sections obtained with contrast and dextran, respectively (P = 0.45). The mean lumen areas were also similar: 6.69 ± 1.95 mm(2) with iodixanol vs. 7.06 ± 2.06 mm(2) with dextran (correlation coefficient 0.984). The image quality and measurements during OCT image acquisition are similar for dextran and contrast. Dextran could be used instead of contrast for OCT imaging, especially in patients in whom contrast load minimization is desired. © 2013 Wiley Periodicals, Inc.

  20. Targeted sections in either XY or XZ plane with dual-axes confocal endomicroscope (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Li, Gaoming; Li, Haijun; Duan, Xiyu; Zhou, Quan; Zhou, Juan; Oldham, Kenn R.; Wang, Thomas D.

    2017-02-01

    We demonstrate a dual axes confocal architecture, which can be used to collect horizontal(XY-plane) or vertical cross-sectional(XZ-plane) images for tissue. This scanner head is 5.5mm in outer diameter(OD), and integrates a 3D MEMS scanner with a compact chip size of 3.2×2.9mm2. To realize the miniaturization, there are some obstacles of the small size of 3D MEMS scanner, MEMS wire bundle, the air pressure effect for MEMS motion, the processing of parabolic mirror, and optical alignment to come over. In our probe, separation mechanical structure for optical alignment was adopted and a step shape MEMS holder was designed to deal with the difficult of MEMS wire bundle. Peptides have been demonstrated tremendous potential for in vivo use to detect colonic dysplasia. This class of in vivo molecular probe can be labeled with near-infrared (NIR) dyes for visualizing the full depth of the epithelium in small animals. To confirm our probe performance, we take use of USAF 1951 resolution target to test its lateral and axial resolution. It has lateral and axial resolution of 2.49um and 4.98um, respectively. When we collect the fluorescence imaging of colon, it shows that the field of view are 1000um×1000um (horizontal) and 1000um×430um (vertical). The horizontal and vertical cross-sectional images of fresh mouse colonic mucosa demonstrate imaging performance with this miniature instrument.

  1. Uniform field loop-gap resonator and rectangular TEU02 for aqueous sample EPR at 94 GHz

    NASA Astrophysics Data System (ADS)

    Sidabras, Jason W.; Sarna, Tadeusz; Mett, Richard R.; Hyde, James S.

    2017-09-01

    In this work we present the design and implementation of two uniform-field resonators: a seven-loop-six-gap loop-gap resonator (LGR) and a rectangular TEU02 cavity resonator. Each resonator has uniform-field-producing end-sections. These resonators have been designed for electron paramagnetic resonance (EPR) of aqueous samples at 94 GHz. The LGR geometry employs low-loss Rexolite end-sections to improve the field homogeneity over a 3 mm sample region-of-interest from near-cosine distribution to 90% uniform. The LGR was designed to accommodate large degassable Polytetrafluorethylen (PTFE) tubes (0.81 mm O.D.; 0.25 mm I.D.) for aqueous samples. Additionally, field modulation slots are designed for uniform 100 kHz field modulation incident at the sample. Experiments using a point sample of lithium phthalocyanine (LiPC) were performed to measure both the uniformity of the microwave magnetic field and 100 kHz field modulation, and confirm simulations. The rectangular TEU02 cavity resonator employs over-sized end-sections with sample shielding to provide an 87% uniform field for a 0.1 × 2 × 6 mm3 sample geometry. An evanescent slotted window was designed for light access to irradiate 90% of the sample volume. A novel dual-slot iris was used to minimize microwave magnetic field perturbations and maintain cross-sectional uniformity. Practical EPR experiments using the application of light irradiated rose bengal (4,5,6,7-tetrachloro-2‧,4‧,5‧,7‧-tetraiodofluorescein) were performed in the TEU02 cavity. The implementation of these geometries providing a practical designs for uniform field resonators that continue resonator advancements towards quantitative EPR spectroscopy.

  2. The Influence of Corrosion and Cross-Section Diameter on the Mechanical Properties of B500c Steel

    NASA Astrophysics Data System (ADS)

    Apostolopoulos, Ch. Alk.

    2009-03-01

    Corrosion is a negative contributor on the structural integrity of concrete structures and leads to degradation of the mechanical properties of steel rebar. Exposure to chloride, seawater, salt and saltwater and deicing chemical environments influences the concrete-steel bond and weakens it. A considerable strength factor of the two-phase steel B500c (martensitic, ferritic-perlitic) is considered to be the outer martensitic cortex thickness, which varies according to the area of the rebar cross section. In order to evaluate the influence of corrosion and the size of the area on the mechanical properties of B500c steel, an experimental investigation was conducted on B500c ribbed steel rebar of 8, 12, 16, and 18 mm diameter, and which were artificially corroded for 10, 20, 30, 45, 60, 90, and 120 days. The laboratory tests suggest that corrosion duration and rebar cross-sectional area size had a significant impact on the strength and ductility degradation of the specimens. The tensile mechanical properties before and after corrosion indicated progressive variation and drastic drop in their values. The extended salt spray exposure enhanced the damage and created pits and notches, resulting in stress concentration points and progressive reduction of ductility and available energy. Anti-seismic design and codes that ignore the influence of the size of the cross-section area and the level of corrosion and mechanical behavior of reinforcing steel could lead to unpredictable performance during severe ground motion.

  3. Correlation among ultrasound, cross-sectional anatomy, and histology of the sciatic nerve: a review.

    PubMed

    Moayeri, Nizar; van Geffen, Geert J; Bruhn, Jörgen; Chan, Vincent W; Groen, Gerbrand J

    2010-01-01

    Efficient identification of the sciatic nerve (SN) requires a thorough knowledge of its topography in relation to the surrounding structures. Anatomic cross sections in similar oblique planes as observed during SN ultrasonography are lacking. A survey of sonoanatomy matched with ultrasound views of the major SN block sites will be helpful in pattern recognition, especially when combined with images that show the internal architecture of the nerve. From 1 cadaver, consecutive parts of the upper leg corresponding to the 4 major blocks sites were sectioned and deeply frozen. Using cryomicrotomy, consecutive transverse sections were acquired and photographed at 78-microm intervals, along with histologic sections at 5-mm intervals. Multiplanar reformatting was done to reconstruct the optimal planes for an accurate comparison of ultrasonography and gross anatomy. The anatomic and histologic images were matched with ultrasound images that were obtained from 2 healthy volunteers. By simulating the exact position and angulation as in the ultrasonographic images, detailed anatomic overviews of SN and adjacent structures were reconstructed in the gluteal, subgluteal, midfemoral, and popliteal regions. Throughout its trajectory, SN contains numerous fascicles with connective and adipose tissues. In this study, we provide an optimal matching between histology, anatomic cross sections, and short-axis ultrasound images of SN. Reconstructing ultrasonographic planes with this high-resolution digitized anatomy not only enables an overview but also shows detailed views of the architecture of internal SN. The undulating course of the nerve fascicles within SN may explain its varying echogenic appearance during probe manipulation.

  4. Energy Transfer Highway in Nd3+-Sensitized Nanoparticles for Efficient near-Infrared Bioimaging.

    PubMed

    Cao, Cong; Xue, Meng; Zhu, Xingjun; Yang, Pengyuan; Feng, Wei; Li, Fuyou

    2017-06-07

    Despite the large absorption cross-section of Nd 3+ dopant as a sensitizer in lanthanide doped luminescence system, the strong cross-relaxation effect of it impedes the promotion of doping concentration and thus reduces the utilization of excitation light. In this work, we introduce a highly efficient acceptor, Yb 3+ ion, which can quickly receive energy from Nd 3+ ions, to construct an energy transfer highway for the enhancement of near-infrared emission. By using the energy transfer highway, the doping amount of Nd 3+ ions in our NaYF 4 :Yb,Nd@CaF 2 core/shell nanoparticles (CSNPs) can be markedly elevated to 60%. The quantum yield of CSNPs was determined to be 20.7%, which provides strong near-infrared luminescence for further bioimaging application. Remarkably, deep tissue penetration depth (∼10 mm) in in vitro imaging and high spatial resolution of blood vessel (∼0.19 mm) in in vivo imaging were detected clearly with weak autofluorescence, demonstrating that probes can be used as excellent NIR biosensors.

  5. Scalable pumping approach for extracting the maximum TEM(00) solar laser power.

    PubMed

    Liang, Dawei; Almeida, Joana; Vistas, Cláudia R

    2014-10-20

    A scalable TEM(00) solar laser pumping approach is composed of four pairs of first-stage Fresnel lens-folding mirror collectors, four fused-silica secondary concentrators with light guides of rectangular cross-section for radiation homogenization, four hollow two-dimensional compound parabolic concentrators for further concentration of uniform radiations from the light guides to a 3 mm diameter, 76 mm length Nd:YAG rod within four V-shaped pumping cavities. An asymmetric resonator ensures an efficient large-mode matching between pump light and oscillating laser light. Laser power of 59.1 W TEM(00) is calculated by ZEMAX and LASCAD numerical analysis, revealing 20 times improvement in brightness figure of merit.

  6. Military microwaves '84; Proceedings of the Conference, London, England, October 24-26, 1984

    NASA Astrophysics Data System (ADS)

    The present conference on microwave frequency electronic warfare and military sensor equipment developments consider radar warning receivers, optical frequency spread spectrum systems, mobile digital communications troposcatter effects, wideband bulk encryption, long range air defense radars (such as the AR320, W-2000 and Martello), multistatic radars, and multimode airborne and interceptor radars. IR system and subsystem component topics encompass thermal imaging and active IR countermeasures, class 1 modules, and diamond coatings, while additional radar-related topics include radar clutter in airborne maritime reconnaissance systems, microstrip antennas with dual polarization capability, the synthesis of shaped beam antenna patterns, planar phased arrays, radar signal processing, radar cross section measurement techniques, and radar imaging and pattern analysis. Attention is also given to optical control and signal processing, mm-wave control technology and EW systems, W-band operations, planar mm-wave arrays, mm-wave monolithic solid state components, mm-wave sensor technology, GaAs monolithic ICs, and dielectric resonator and wideband tunable oscillators.

  7. A dual-beam spectropluviometer concept

    NASA Astrophysics Data System (ADS)

    Delahaye, J.-Y.; Barthès, L.; Golé, P.; Lavergnat, J.; Vinson, J. P.

    2006-08-01

    SummaryA dual beam spectropluviometer (DBS) measuring the equivalent diameter D, the fall velocity V and the time T of arrival of particles is presented. Its main advantage over previous optical disdrometers is the whole measurement range of atmospheric precipitating particles near the ground. In the bottom part of the size range, 0.1 mm has been the smallest observable diameter. The means for obtaining such results are (i) two uniform infrared beams of rectangular cross-section 2 mm in height, 40 mm in width and 250 mm in length, with a 2 mm vertical gap in-between, (ii) a dual 16-bit analog to digital converter, (iii) a dedicated program for extracting the three parameters in real time by computing the signal slopes and determining the correlation between both channels used in this first version of the instrument, (iv) various means for reducing spurious detections caused by splashing, vibration and sunlight. Laboratory tests and typical rain measurements are shown. The DBS is particularly suited for extensive atmospheric and radio propagation research applications where the smallest drops were not correctly estimated in the distributions because of the lack of appropriate measurement devices.

  8. A new transportable instrument for in-situ void and corrosion imaging in thick structural sections by three dimensional Compton scatter imaging

    NASA Astrophysics Data System (ADS)

    Bridge, B.

    2000-05-01

    When X Gamma or other kinds of subatomic particle radiation are being used for NDE, measurements are almost always made on the primary beam after transmission through the object under test. Cases are described where better results, i.e., image quality or cost effectiveness can be obtained from measurements on scattered radiation rather than the primary beam. Compton imaging of high volume resolution in thick structures has previously been achieved only by fixed laboratory installations involving massive primary beam shields (collimators) between source and detectors. Here the design of a relatively portable collimator (98 kg mass) for a cobalt 60 source is given. It permits three dimensional material density imaging, with voxel (3-dimensional pixel) volumes small enough to permit the detection of voids down to 10 cubic mm in up to 30 mm thickness of steel or 250 mm of wood (for example, a 500 mm diameter tree trunk). Using a 370 GBq source, typical results of thickness measurements to a precision of 1 mm over cross sections down to 10 square mm are presented. The collimator mass is reducible to about 68 kg with the use of depleted uranium instead of lead. The means of deploying such a collimator in a mobile way are discussed. A typical in-situ application is the detection of inner wall corrosion and flooding of tubular members of underwater offshore oil platforms and ship hulls without the need to remove hard marine growth. Another case is the detection of telegraph pole and tree rot below ground level.

  9. Vertical load capacities of roof truss cross members.

    PubMed

    Gearhart, David F; Morsy, Mohamed Khaled

    2016-05-01

    Trusses used for roof support in coal mines are constructed of two grouted bolts installed at opposing forty-five degree angles into the roof and a cross member that ties the angled bolts together. The load on the cross member is vertical, which is transverse to the longitudinal axis, and therefore the cross member is loaded in the weakest direction. Laboratory tests were conducted to determine the vertical load capacity and deflection of three different types of cross members. Single-point load tests, with the load applied in the center of the specimen and double-point load tests, with a span of 2.4 m, were conducted. For the single-point load configuration, the yield of the 25 mm solid bar cross member was nominally 98 kN of vertical load, achieved at 42 cm of deflection. For cable cross members, yield was not achieved even after 45 cm of deflection. Peak vertical loads were about 89 kN for 17 mm cables and 67 kN for the 15 mm cables. For the double-point load configurations, the 25 mm solid bar cross members yielded at 150 kN of vertical load and 25 cm of deflection. At 25 cm of deflection individual cable strands started breaking at 133 and 111 kN of vertical load for the 17 and 15 mm cable cross members respectively.

  10. Development of a mercuric iodide detector array for in-vivo x-ray imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patt, B.E.; Iwanczyk, J.S.; Tornai, M.P.

    A nineteen element mercuric iodide (HgI{sub 2}) detector array has been developed in order to investigate the potential of using this technology for in-vivo x-ray and gamma-ray imaging. A prototype cross-grid detector array was constructed with hexagonal pixels of 1.9 mm diameter (active area = 3.28 mm{sup 2}) and 0.2 mm thick septa. The overall detector active area is roughly 65 mm{sup 2}. A detector thickness of 1.2 mm was used to achieve about 100% efficiency at 60 keV and 67% efficiency at 140 keV The detector fabrication, geometry and structure were optimized for charge collection and to minimize crosstalkmore » between elements. A section of a standard high resolution cast-lead gamma-camera collimator was incorporated into the detector to provide collimation matching the discrete pixel geometry. Measurements of spectral and spatial performance of the array were made using 241-Am and 99m-Tc sources. These measurements were compared with similar measurements made using an optimized single HgI{sub 2} x-ray detector with active area of about 3 mm{sup 2} and thickness of 500 {mu}m.« less

  11. Magnetomotive Optical Coherence Elastography for Magnetic Hyperthermia Dosimetry Based on Dynamic Tissue Biomechanics

    PubMed Central

    Huang, Pin-Chieh; Pande, Paritosh; Ahmad, Adeel; Marjanovic, Marina; Spillman, Darold R.; Odintsov, Boris; Boppart, Stephen A.

    2016-01-01

    Magnetic nanoparticles (MNPs) have been used in many diagnostic and therapeutic biomedical applications over the past few decades to enhance imaging contrast, steer drugs to targets, and treat tumors via hyperthermia. Optical coherence tomography (OCT) is an optical biomedical imaging modality that relies on the detection of backscattered light to generate high-resolution cross-sectional images of biological tissue. MNPs have been utilized as imaging contrast and perturbative mechanical agents in OCT in techniques called magnetomotive OCT (MM-OCT) and magnetomotive elastography (MM-OCE), respectively. MNPs have also been independently used for magnetic hyperthermia treatments, enabling therapeutic functions such as killing tumor cells. It is well known that the localized tissue heating during hyperthermia treatments result in a change in the biomechanical properties of the tissue. Therefore, we propose a novel dosimetric technique for hyperthermia treatment based on the viscoelasticity change detected by MM-OCE, further enabling the theranostic function of MNPs. In this paper, we first review the basic principles and applications of MM-OCT, MM-OCE, and magnetic hyperthermia, and present new preliminary results supporting the concept of MM-OCE-based hyperthermia dosimetry. PMID:28163565

  12. The quantitative measurements of foveal avascular zone using optical coherence tomography angiography in normal volunteers.

    PubMed

    Ghassemi, Fariba; Mirshahi, Reza; Bazvand, Fatemeh; Fadakar, Kaveh; Faghihi, Houshang; Sabour, Siamak

    2017-12-01

    To provide normative data of foveal avascular zone (FAZ) and thickness. In this cross-sectional study both eyes of each normal subject were scanned with optical coherence tomography angiography (OCTA) for foveal superficial and deep avascular zone (FAZ) and central foveal thickness (CFT) and parafoveal thickness (PFT). Out of a total of 224 eyes of 112 volunteers with a mean age of 37.03 (12-67) years, the mean superficial FAZ area was 0.27 mm 2 , and deep FAZ area was 0.35 mm 2 ( P  < 0.001), with no difference between both eyes. Females had a larger superficial (0.32 ± 0.11 mm 2 versus 0.23 ± 0.09 mm 2 ) and deep FAZ (0.40 ± 0.14 mm 2 versus 0.31 ± 0.10 mm 2 ) ( P  < 0.001) than males. By multivariate linear regression analysis, in normal eyes, superficial FAZ area varied significantly with the gender, CFT, and deep FAZ. Deep FAZ varied with the gender and CFT. The gender and CFT influence the size of normal superficial and deep FAZ of capillary network.

  13. Congenital lumbar spinal stenosis: a prospective, control-matched, cohort radiographic analysis.

    PubMed

    Singh, Kern; Samartzis, Dino; Vaccaro, Alexander R; Nassr, Ahmad; Andersson, Gunnar B; Yoon, S Tim; Phillips, Frank M; Goldberg, Edward J; An, Howard S

    2005-01-01

    Degenerative lumbar spinal stenosis manifests primarily after the sixth decade of life as a result of facet hypertrophy and degenerative disc disease. Congenital stenosis, on the other hand, presents earlier in age with similar clinical findings but with multilevel involvement and fewer degenerative changes. These patients may have subtle anatomic variations of the lumbar spine that may increase the likelihood of thecal sac compression. However, to the authors' knowledge, no quantitative studies have addressed various radiographic parameters of symptomatic, congenitally stenotic individuals to normal subjects. To radiographically quantify and compare the anatomy of the lumbar spine in symptomatic, congenitally stenotic individuals to age- and sex-matched, asymptomatic, nonstenotic controlled individuals. A prospective, control-matched, cohort radiographic analysis. Axial and sagittal magnetic resonance imaging (MRI) and lateral, lumbar, plain radiographs of 20 surgically treated patients who were given a clinical diagnosis of congenital lumbar stenosis by the senior author were randomized with images of 20, asymptomatic age- and sex-matched subjects. MRIs and lateral, lumbar, plain radiographs were independently quantitatively assessed by two individuals. Measurements obtained from the axial MRIs included: midline anterior-posterior (AP) vertebral body diameter, vertebral body width, midline AP canal diameter, canal width, spinal canal cross-sectional area, pedicle length, and pedicle width. From the sagittal MRIs, the following measurements were calculated: AP vertebral body diameter, vertebral body height, and AP canal diameter at the mid-vertebral level. On the lateral, lumbar, plain radiograph (L3 level), the AP diameters of the vertebral body spinal canal were measured. The images of these 40 individuals were then randomized and distributed in a blinded fashion to five separate spine surgeons who graded the presence and severity of congenital stenosis utilizing a five-tier scale. Images consisting of 15 symptomatic individuals, graded definitely congenitally stenotic (mean age, 51.7 years; range, 43-65 years), and 15 asymptomatic individuals, graded definitely not stenotic (mean age, 50.7 years; range, 41-55 years), were age- and sex-matched and included for further review. From these 30 patients, a lateral, lumbar, plain radiograph and axial and sagittal MRIs (T1/T2 weighted) from L2-L5 were quantitatively analyzed. Rater reliability was assessed by Kappa coefficient testing. The cross-sectional area of the canal was significantly smaller in the congenitally stenotic patients at all lumbar levels measured (L2: 176 mm(2) vs. 259 mm(2), L3: 177 mm(2) vs. 275 mm(2), L4: 183 mm(2) vs. 283 mm(2), L5: 213 mm(2) vs. 323 mm(2), p<.05). Pedicle length was markedly shorter in the stenosis group at each lumbar level (L2: 5.9 mm vs. 8.9 mm, L3: 6.0 mm vs. 8.8 mm, L4: 6.5 mm vs. 9.2 mm, L5: 5.8 mm vs. 9.1 mm, p<.05). Furthermore, midline, axial AP canal diameter, vertebral body width, and sagittal AP canal diameter were all significantly smaller than the control patients (p<.05). A ratio of the AP diameter of the pedicle length to the vertebral body was also noted to be statistically significant on both the lateral plain radiographs (L3: 0.426 vs. 0.704) and sagittal MRI (L2: 0.343 vs. 0.461, L3: 0.361 vs. 0.461, L4: 0.362 vs. 0.481, L5: 0.354 vs. 0.452, p<.05). No difference was noted comparing the AP diameter of the vertebral body (axial and sagittal images), vertebral body height, canal width, and pedicle width. Kappa testing coefficient indicated a strong rater reliability (k=0.81, 95% confidence interval: 0.62-0.94). Congenital lumbar stenosis has not been clearly defined radiographically. Clinically, congenitally stenotic patients present at a younger age with fewer degenerative changes and multiple levels of involvement. Radiographically, these patients have a shorter pedicular length and as a result a smaller cross-sectional spinal canal area (mean critical values of 6.5 mm and 213 mm(2) were observed, respectively). The mean critical ratios were 0.43 (2:1 AP vertebral body: pedicle length) on the lateral lumbar radiograph and 0.36 on the sagittal MRI. The altered canal anatomy resulting from a decreased pedicle length may anatomically predispose these patients to earlier complaints of symptomatic neurogenic claudication. Identification of the presence of congenital stenosis should increase the treating surgeon's awareness of the potential need for multilevel treatment.

  14. The measurement of creep in ultrahigh molecular weight polyethylene: a comparison of conventional versus highly cross-linked polyethylene.

    PubMed

    Estok, Daniel M; Bragdon, Charles R; Plank, Gordon R; Huang, Anna; Muratoglu, Orhun K; Harris, William H

    2005-02-01

    Quantification of creep of highly cross-linked polyethylene would enable separation of creep from wear when evaluating femoral head penetration into polyethylene. We compared creep magnitude of a highly cross-linked versus conventional polyethylene in the laboratory. Twelve acetabular liners of each material were tested, 6 of which had a 32-mm inner diameter (ID) and 6 had 28-mm ID. Creep was measured using coordinate measuring machines during loading at 2 Hz without motion to 4 million cycles. Penetration into 32-mm ID conventional liners reached 97 microm versus 107 microm for highly cross-linked material, not significant. Penetration into 28-mm conventional liners was 132 microm versus 155 microm for highly cross-linked material (P = .017). Ninety percent of the creep had occurred by 2.5 million cycles.

  15. Fabrication of parabolic cylindrical microlens array by shaped femtosecond laser

    NASA Astrophysics Data System (ADS)

    Luo, Zhi; Yin, Kai; Dong, Xinran; Duan, Ji'an

    2018-04-01

    A simple and efficient technique for fabricating parabolic cylindrical microlens arrays (CMLAs) on the surface of fused silica by shaped femtosecond (fs) laser direct-writing is demonstrated. By means of spatially shaping of a Gaussian fs laser beam to a Bessel distribution, an inversed cylindrical shape laser intensity profile is formed in a specific cross-sectional plane among the shaped optical field. Applying it to experiments, large area close-packed parabolic CMLAs with line-width of 37.5 μm and array size of about 5 × 5 mm are produced. The cross-sectional outline of obtained lenslets has a satisfied parabolic profile and the numerical aperture (NA) of lenslets is more than 0.35. Furthermore, the focusing performance of the fabricated CMLA is also tested in this work and it has been demonstrated that the focusing power of the CMLA with a parabolic profile is better than that with a semi-circular one.

  16. Minimum joint space width and tibial cartilage morphology in the knees of healthy individuals: A cross-sectional study

    PubMed Central

    Beattie, Karen A; Duryea, Jeffrey; Pui, Margaret; O'Neill, John; Boulos, Pauline; Webber, Colin E; Eckstein, Felix; Adachi, Jonathan D

    2008-01-01

    Background The clinical use of minimum joint space width (mJSW) and cartilage volume and thickness has been limited to the longitudinal measurement of disease progression (i.e. change over time) rather than the diagnosis of OA in which values are compared to a standard. This is primarily due to lack of establishment of normative values of joint space width and cartilage morphometry as has been done with bone density values in diagnosing osteoporosis. Thus, the purpose of this pilot study is to estimate reference values of medial joint space width and cartilage morphometry in healthy individuals of all ages using standard radiography and peripheral magnetic resonance imaging. Design For this cross-sectional study, healthy volunteers underwent a fixed-flexion knee X-ray and a peripheral MR (pMR) scan of the same knee using a 1T machine (ONI OrthOne™, Wilmington, MA). Radiographs were digitized and analyzed for medial mJSW using an automated algorithm. Only knees scoring ≤1 on the Kellgren-Lawrence scale (no radiographic evidence of knee OA) were included in the analyses. All 3D SPGRE fat-sat sagittal pMR scans were analyzed for medial tibial cartilage morphometry using a proprietary software program (Chondrometrics GmbH). Results Of 119 healthy participants, 73 were female and 47 were male; mean (SD) age 38.2 (13.2) years, mean BMI 25.0 (4.4) kg/m2. Minimum JSW values were calculated for each sex and decade of life. Analyses revealed mJSW did not significantly decrease with increasing decade (p > 0.05) in either sex. Females had a mean (SD) medial mJSW of 4.8 (0.7) mm compared to males with corresponding larger value of 5.7 (0.8) mm. Cartilage morphometry results showed similar trends with mean (SD) tibial cartilage volume and thickness in females of 1.50 (0.19) μL/mm2 and 1.45 (0.19) mm, respectively, and 1.77 (0.24) μL/mm2 and 1.71 (0.24) mm, respectively, in males. Conclusion These data suggest that medial mJSW values do not decrease with aging in healthy individuals but remain fairly constant throughout the lifespan with "healthy" values of 4.8 mm for females and 5.7 mm for males. Similar trends were seen for cartilage morphology. Results suggest there may be no need to differentiate a t-score and a z-score in OA diagnosis because cartilage thickness and JSW remain constant throughout life in the absence of OA. PMID:18778479

  17. Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages.

    PubMed

    Carlton, Holly D; Elmer, John W; Li, Yan; Pacheco, Mario; Goyal, Deepak; Parkinson, Dilworth Y; MacDowell, Alastair A

    2016-04-13

    Synchrotron radiation micro-tomography (SRµT) is a non-destructive three-dimensional (3D) imaging technique that offers high flux for fast data acquisition times with high spatial resolution. In the electronics industry there is serious interest in performing failure analysis on 3D microelectronic packages, many which contain multiple levels of high-density interconnections. Often in tomography there is a trade-off between image resolution and the volume of a sample that can be imaged. This inverse relationship limits the usefulness of conventional computed tomography (CT) systems since a microelectronic package is often large in cross sectional area 100-3,600 mm(2), but has important features on the micron scale. The micro-tomography beamline at the Advanced Light Source (ALS), in Berkeley, CA USA, has a setup which is adaptable and can be tailored to a sample's properties, i.e., density, thickness, etc., with a maximum allowable cross-section of 36 x 36 mm. This setup also has the option of being either monochromatic in the energy range ~7-43 keV or operating with maximum flux in white light mode using a polychromatic beam. Presented here are details of the experimental steps taken to image an entire 16 x 16 mm system within a package, in order to obtain 3D images of the system with a spatial resolution of 8.7 µm all within a scan time of less than 3 min. Also shown are results from packages scanned in different orientations and a sectioned package for higher resolution imaging. In contrast a conventional CT system would take hours to record data with potentially poorer resolution. Indeed, the ratio of field-of-view to throughput time is much higher when using the synchrotron radiation tomography setup. The description below of the experimental setup can be implemented and adapted for use with many other multi-materials.

  18. Elevated-temperature Deformation Mechanisms in Ta2C: An Experimental Study

    DTIC Science & Technology

    2013-01-01

    result, tan- talum carbides have found uses in a variety of wear- resis - tant applications including machine tooling, coatings for injection molding...HIP billet. In addition , the near surface of the bil- let was mechanically ground to remove any possible inter- diffusion reaction zone between the...mounted in a conductive epoxy for handling. TEM foils were prepared by ultrasonically drilling 3 mm discs from the cross-sections using a Fischione

  19. Algorithm for Surface of Translation Attached Radiators (A-STAR). Volume 2. Users manual

    NASA Astrophysics Data System (ADS)

    Medgyesimitschang, L. N.; Putnam, J. M.

    1982-05-01

    A hierarchy of computer programs implementing the method of moments for bodies of translation (MM/BOT) is described. The algorithm treats the far-field radiation from off-surface and aperture antennas on finite-length open or closed bodies of arbitrary cross section. The near fields and antenna coupling on such bodies are computed. The theoretical development underlying the algorithm is described in Volume 1 of this report.

  20. Analysis of optic disc change using the heidelberg retina tomograph in an acquired pit of the optic nerve.

    PubMed

    Oh, Joo Youn; Park, Ki Ho

    2004-01-01

    A 51-year-old woman diagnosed as having normal-tension glaucoma developed an acquired pit of the optic nerve. The optic disc was viewed by the Heidelberg Retina Tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany) before and after development of an acquired pit of the optic nerve. HRT parameters and cross-sectional images of the optic disc were compared. Maximum cup depth at the site of the acquired pit of the optic nerve increased after development of the acquired pit of the optic nerve (from 1.200 to 2.432 mm). The neuroretinal rim area and volume in the inferotemporal octant were reduced (rim area from 0.070 to 0.010 mm2, rim volume from 0.009 to 0.001 mm3). The morphologic changes in the optic disc were also detected topographically and reflectively.

  1. A microfabricated optically-pumped magnetic gradiometer

    NASA Astrophysics Data System (ADS)

    Sheng, D.; Perry, A. R.; Krzyzewski, S. P.; Geller, S.; Kitching, J.; Knappe, S.

    2017-01-01

    We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60 mm and cross sectional diameter of 12 mm, and consists of two chip-scale atomic magnetometers which are interrogated by a common laser light. The sensor can measure differences in magnetic fields, over a 20 mm baseline, of 10 fT/ Hz1 /2 at frequencies above 20 Hz. The maximum rejection of magnetic field noise is 1000 at 10 Hz. By use of a set of compensation coils wrapped around the sensor, we also measure the sensor sensitivity at several external bias field strengths up to 150 mG. This device is useful for applications that require both sensitive gradient field information and high common-mode noise cancellation.

  2. Accurate real-time sensing tip for aqueous NO with optical fibers embedded in active hydrogel waveguide

    NASA Astrophysics Data System (ADS)

    Chung, Chieh-Wen; Tsai, May-Jywan; Lin, Peng-Wei; Huang, Ding-Wen; Wang, Kuan-Hsun; Chen, Yu-An; Meng, Hsin-Fei; Zan, Hsiao-Wen; Cheng, Henrich; Tong, Limin; Zhang, Lei; Horng, Sheng-Fu; Hung, Cheng-Hsiung

    2018-02-01

    A NO sensing tip is made by inserting two parallel optical fibers inside a poly 2-hydroxyethyl methacrylate (PolyHEMA) hydrogel waveguide mixed with the probe molecule 1, 2-Diaminoanthraquinone (DAQ). There is a length difference of 1 mm between the two fibers, and the light has to propagate through the difference from the short fiber to the long fiber. The total cross section area of the active hydrogel waveguide embedded with the fibers is only 3mm x 1.2 mm. For practical use the tip is housed in a needle for mechanical protection and the sensing tip is able to detect aqueous NO concentration around 1 μM with time resolution about 5 minutes. Such a sensing tip can be used to monitor the medical conditions inside the brain after a stroke or a brain injury.

  3. Modified retrieval algorithm for three types of precipitation distribution using x-band synthetic aperture radar

    NASA Astrophysics Data System (ADS)

    Xie, Yanan; Zhou, Mingliang; Pan, Dengke

    2017-10-01

    The forward-scattering model is introduced to describe the response of normalized radar cross section (NRCS) of precipitation with synthetic aperture radar (SAR). Since the distribution of near-surface rainfall is related to the rate of near-surface rainfall and horizontal distribution factor, a retrieval algorithm called modified regression empirical and model-oriented statistical (M-M) based on the volterra integration theory is proposed. Compared with the model-oriented statistical and volterra integration (MOSVI) algorithm, the biggest difference is that the M-M algorithm is based on the modified regression empirical algorithm rather than the linear regression formula to retrieve the value of near-surface rainfall rate. Half of the empirical parameters are reduced in the weighted integral work and a smaller average relative error is received while the rainfall rate is less than 100 mm/h. Therefore, the algorithm proposed in this paper can obtain high-precision rainfall information.

  4. An Approach with Hybrid Segmental Mechanics.

    PubMed

    Mishra, Harsh Ashok; Maurya, Raj Kumar

    2016-06-01

    Present case report provides an insight into the hybrid segmental mechanics with treatment of 13-year-old male, considering the side effects of sole continuous arch wire sliding mechanics. Patient was diagnosed as a case of skeletal class I jaw relationship, low mandibular plane angle, class II molar relation on right and class I molar relation on left side, anterior cross bite, crowding of 12mm in upper, 5mm in lower arch. He also had proclined upper and lower anteriors by 2mm, convex profile and incompetent lips. Total treatment duration was 20 months, during which segmental canine retraction was performed with TMA (Titanium, Molybdenum, Aluminum) 'T' loop retraction spring followed by consolidation of spaces with continuous arch mechanics. Most of the treatment objectives were met with good intraoral and facial results within reasonable framework of time. This approach used traditional twin brackets, which offered the versatility to use continuous arch-wire mechanics, segmental mechanics and hybrid sectional mechanics.

  5. Hypertension in the very old; prevalence, awareness, treatment and control: a cross-sectional population-based study in a Spanish municipality.

    PubMed

    Aguado, Alba; López, Flora; Miravet, Sonia; Oriol, Pilar; Fuentes, M Isabel; Henares, Belén; Badia, Teresa; Esteve, Lluis; Peligro, Javier

    2009-05-08

    Information on hypertension in the very elderly is sparse. Until recently evidence of benefits from pharmacological treatment was inconclusive. We estimated the prevalence of hypertension in subjects aged 80 or more, the proportion of awareness, treatment and control. Explanatory variables associated with good control were also studied. Cross sectional, population-based study, conducted in Martorell, an urban Spanish municipality, in 2005. By simple random sampling from the census, 323 subjects aged 80 or more were included. Patients were visited at home or in the geriatric institution and after giving informed consent, the study variables were collected. These included: supine and standing blood pressure and information about diagnosis and treatment of hypertension. The estimation and 95% confidence interval were obtained and a logistic regression model was used to study explanatory variables associated with blood pressure below 140/90 mm Hg. The prevalence of hypertension was 72.8% (95%CI: 69.5-76.6%) and 93% of the patients were aware of this condition, of whom 96.3% (95%CI: 93.65-97.9%) had been prescribed pharmacological treatment and 30.7% (95%CI: 25.8 - 36.1%) had blood pressure below 140/90 mm Hg. Some of the patients (43%) had one antihypertensive drug and 39.5% had two in combination. Explanatory variables associated with blood pressure below 140/90 mm Hg included prescription of a diuretic, OR: 0.31 (95%CI: 0.14-0.66), and history of ischemic heart disease, OR: 0.21 (95%CI: 0.1-0.47). The prevalence of hypertension in population aged 80 or more was over 70%. Most patients were aware of this condition and they had antihypertensive medication prescribed. Approximately one third of treated patients had blood pressure below 140/90 mm Hg. Patients with heart disease and with diuretics had more frequently blood pressure below this value.

  6. Hypertension in the very old; prevalence, awareness, treatment and control: a cross-sectional population-based study in a Spanish municipality

    PubMed Central

    Aguado, Alba; López, Flora; Miravet, Sonia; Oriol, Pilar; Fuentes, M Isabel; Henares, Belén; Badia, Teresa; Esteve, Lluis; Peligro, Javier

    2009-01-01

    Background Information on hypertension in the very elderly is sparse. Until recently evidence of benefits from pharmacological treatment was inconclusive. We estimated the prevalence of hypertension in subjects aged 80 or more, the proportion of awareness, treatment and control. Explanatory variables associated with good control were also studied. Methods Cross sectional, population-based study, conducted in Martorell, an urban Spanish municipality, in 2005. By simple random sampling from the census, 323 subjects aged 80 or more were included. Patients were visited at home or in the geriatric institution and after giving informed consent, the study variables were collected. These included: supine and standing blood pressure and information about diagnosis and treatment of hypertension. The estimation and 95% confidence interval were obtained and a logistic regression model was used to study explanatory variables associated with blood pressure below 140/90 mm Hg. Results The prevalence of hypertension was 72.8% (95%CI: 69.5 – 76.6%) and 93% of the patients were aware of this condition, of whom 96.3% (95%CI: 93.65 – 97.9%) had been prescribed pharmacological treatment and 30.7% (95%CI: 25.8 – 36.1%) had blood pressure below 140/90 mm Hg. Some of the patients (43%) had one antihypertensive drug and 39.5% had two in combination. Explanatory variables associated with blood pressure below 140/90 mm Hg included prescription of a diuretic, OR: 0.31 (95%CI: 0.14 – 0.66), and history of ischemic heart disease, OR: 0.21 (95%CI: 0.1 – 0.47). Conclusion The prevalence of hypertension in population aged 80 or more was over 70%. Most patients were aware of this condition and they had antihypertensive medication prescribed. Approximately one third of treated patients had blood pressure below 140/90 mm Hg. Patients with heart disease and with diuretics had more frequently blood pressure below this value. PMID:19426484

  7. Scan-rescan precision of subchondral bone curvature maps from routine 3D DESS water excitation sequences: Data from the Osteoarthritis Initiative.

    PubMed

    Farber, Joshua M; Totterman, Saara M S; Martinez-Torteya, Antonio; Tamez-Peña, Jose G

    2016-02-01

    Subchondral bone (SCB) undergoes changes in the shape of the articulating bone surfaces and is currently recognized as a key target in osteoarthritis (OA) treatment. The aim of this study was to present an automated system that determines the curvature of the SCB regions of the knee and to evaluate its cross-sectional and longitudinal scan-rescan precision Six subjects with OA and six control subjects were selected from the Osteoarthritis Initiative (OAI) pilot study database. As per OAI protocol, these subjects underwent 3T MRI at baseline and every twelve months thereafter, including a 3D DESS WE sequence. We analyzed the baseline and twenty-four month images. Each subject was scanned twice at these visits, thus generating scan-rescan information. Images were segmented with an automated multi-atlas framework platform and then 3D renderings of the bone structure were created from the segmentations. Curvature maps were extracted from the 3D renderings and morphed into a reference atlas to determine precision, to generate population statistics, and to visualize cross-sectional and longitudinal curvature changes. The baseline scan-rescan root mean square error values ranged from 0.006mm(-1) to 0.013mm(-1), and from 0.007mm(-1) to 0.018mm(-1) for the SCB of the femur and the tibia, respectively. The standardized response of the mean of the longitudinal changes in curvature in these regions ranged from -0.09 to 0.02 and from -0.016 to 0.015, respectively. The fully automated system produces accurate and precise curvature maps of femoral and tibial SCB, and will provide a valuable tool for the analysis of the curvature changes of articulating bone surfaces during the course of knee OA. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Association of cross-sectional area of the rectus capitis posterior minor muscle with active trigger points in chronic tension-type headache: a pilot study.

    PubMed

    Fernández-de-Las-Peñas, César; Cuadrado, María Luz; Arendt-Nielsen, Lars; Ge, Hong-You; Pareja, Juan A

    2008-03-01

    To investigate whether cross-sectional area (CSA) of the suboccipital muscles was associated with active trigger points (TrPs) in chronic tension-type headache (CTTH). Magnetic resonance imaging (MRI) of the cervical spine was performed in 11 females with CTTH aged from 26 to 50 yrs old. CSA for both rectus capitis posterior minor (RCPmin) and rectus capitis posterior major (RCPmaj) muscles were measured from axial T1-weighted images, using axial MRI slices aligned parallel to the C2/3 intervertebral disc. A headache diary was kept for 4 wks to record the pain history. TrPs in the suboccipital muscle were identified by eliciting referred pain to palpation, and increased referred pain with muscle contraction. TrPs were considered active if the elicited referred pain reproduced the head pain pattern and features of the pattern seen during spontaneous headache attacks. Active TrPs were found in six patients (55%), whereas the remaining five patients showed latent TrPs. CSA of the RCPmin was significantly smaller (F = 13.843; P = 0.002) in the patients with active TrPs (right side: 55.9 +/- 4.4 mm; left side: 61.1 +/-: 3.8 mm) than in patients with latent TrPs (right side: 96.9 +/- 14.4 mm; left side: 88.7 +/- 9.7 mm). No significant differences were found for CSA of the RCPmaj between the patients with either active or latent TrP (P > 0.5). It seems that muscle atrophy in the RCPmin, but not in the RCPmaj, was associated with suboccipital active TrPs in CTTH, although studies with larger sample sizes are now required. It may be that nociceptive inputs in active TrPs could lead to muscle atrophy of the involved muscles. Muscle disuse or avoidance behavior can also be involved in atrophy.

  9. Associations of objectively measured physical activity and abdominal fat distribution.

    PubMed

    Philipsen, Annelotte; Hansen, Anne-Louise Smidt; Jørgensen, Marit Eika; Brage, Søren; Carstensen, Bendix; Sandbaek, Annelli; Almdal, Thomas Peter; Gram, Jeppe; Pedersen, Erling Bjerregaard; Lauritzen, Torsten; Witte, Daniel Rinse

    2015-05-01

    Visceral adipose tissue (VAT) and physical activity are both independent predictors of Type 2 diabetes. Physical activity and overall obesity are inversely associated with each other. Yet the nature of the association between objectively measured dimensions of physical activity and abdominal fat distribution has not been well characterized. We aimed to do so in a middle-age to elderly population at high risk of diabetes. A cross-sectional analysis of 1134 participants of the ADDITION-PRO study. VAT and subcutaneous adipose tissue (SAT) were assessed one-dimensionally by ultrasonography and physical activity with combined accelerometry and HR monitoring. Linear regression of physical activity energy expenditure (PAEE) and time spent in different physical activity intensity levels on VAT and SAT was performed. Median body mass index (BMI) was 26.6 kg·m and PAEE was 28.1 kJ·kg·d, with 18.9 h·d spent sedentary, 4.5 h·d in light-intensity physical activity, and 0.4 h·d in moderate-intensity physical activity. PAEE was significantly negatively associated with VAT, and in women, PAEE was also significantly negatively associated with SAT. The difference in VAT was -1.1 mm (95% confidence interval [CI] = -1.8 to -0.3) per 10-kJ·kg·d increment, and the corresponding difference in SAT for women was -0.6 mm (95% CI = -1.2 to -0.04) in models adjusted for age, sex, and waist circumference. Exchanging 1 h of light physical activity with moderate physical activity was significantly associated with VAT (-4.5 mm, 95% CI = -7.6 to -1.5). Exchanging one sedentary hour with light physical activity was significantly associated with both VAT (-0.9 mm, 95% CI = -0.1 to -1.8) and SAT (-0.4 mm, 95% CI = -0.0 to -0.7). In this population with low physical activity levels, cross-sectional findings indicate that increasing overall physical activity and decreasing time spent sedentary is important to avoid the accumulation of metabolically deleterious VAT.

  10. Combined High Spectral Resolution Lidar and Millimeter Wavelength Radar Measurement of Ice Crystal Precipitation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eloranta, Edwin

    The goal of this research has been to improve measurements of snowfall using a combination of millimeter-wavelength radar and High Spectral Resolution Lidar (HSRL) Observations. Snowflakes are large compared to the 532nm HSRL wavelength and small compared to the 3.2 and 8.6 mm wavelength radars used in this study. This places the particles in the optical scattering regime of the HSRL, where extinction cross-section is proportional to the projected area of the particles, and in the Rayleigh regime for the radar, where the backscatter cross-section is proportional to the mass-squared of the particles. Forming a ratio of the radar measuredmore » cross-section to the HSRL measured cross section eliminates any dependence on the number of scattering particles, yielding a quantity proportional to the average mass-squared of the snowflakes over the average area of the flakes. Using simultaneous radar measurements of particle fall velocities, which are dependent particle mass and cross-sectional area it is possible to derive the average mass of the snow flakes, and with the radar measured fall velocities compute the snowfall rate. Since this retrieval requires the optical extinction cross-section we began by considering errors this quantity. The HSRL is particularly good at measuring the backscatter cross-section. In previous studies of snowfall in the high Arctic were able to estimate the extinction cross-section directly as a fixed ratio to the backscatter cross-section. Measurements acquired in the STORMVEX experiment in Colorado showed that this approach was not valid in mid-latitude snowfalls and that direct measurement of the extinction cross-section is required. Attempts to measure the extinction directly uncovered shortcomings in thermal regulation and mechanical stability of the newly deployed DOE HSRL systems. These problems were largely mitigated by modifications installed in both of the DOE systems. We also investigated other sources of error in the HSRL direct measurement of extinction (see appendix II of this report). We also developed improved algorithms to extract extinction from the HSRL data. These have been installed in the standard HSRL data processing software and are now available to all users of HSRL data. Validation of snowfall measurements has proven difficult due to the unreliability of conventional snowfall measurements coupled with the complexity of considering the vast variety of snowflake geometries. It was difficult to tell how well the algorithm’s approach to accommodating differences in snowflakes was working without good measurements for comparison. As a result, we decided to apply this approach to the somewhat simpler, but scientifically important, problem of drizzle measurement. Here the particle shape is known and the conventional measurement are more reliable. These algorithms where successfully applied to drizzle data acquired during the ARM MAGIC study of marine stratus clouds between California and Hawaii (see Appendix I). This technique is likely to become a powerful tool for studying lifetime of the climatically important marine stratus clouds.« less

  11. Assessing Conifer Ray Parenchyma for Ecological Studies: Pitfalls and Guidelines.

    PubMed

    von Arx, Georg; Arzac, Alberto; Olano, José M; Fonti, Patrick

    2015-01-01

    Ray parenchyma is an essential tissue for tree functioning and survival. This living tissue plays a major role for storage and transport of water, nutrients, and non-structural carbohydrates (NSC), thus regulating xylem hydraulics and growth. However, despite the importance of rays for tree carbon and water relations, methodological challenges hamper knowledge about ray intra- and inter-tree variability and its ecological meaning. In this study we provide a methodological toolbox for soundly quantifying spatial and temporal variability of different ray features. Anatomical ray features were surveyed in different cutting planes (cross-sectional, tangential, and radial) using quantitative image analysis on stem-wood micro-sections sampled from 41 mature Scots pines (Pinus sylvestris). The percentage of ray surface (PERPAR), a proxy for ray volume, was compared among cutting planes and between early- and latewood to assess measurement-induced variability. Different tangential ray metrics were correlated to assess their similarities. The accuracy of cross-sectional and tangential measurements for PERPAR estimates as a function of number of samples and the measured wood surface was assessed using bootstrapping statistical technique. Tangential sections offered the best 3D insight of ray integration into the xylem and provided the most accurate estimates of PERPAR, with 10 samples of 4 mm(2) showing an estimate within ±6.0% of the true mean PERPAR (relative 95% confidence interval, CI95), and 20 samples of 4 mm(2) showing a CI95 of ±4.3%. Cross-sections were most efficient for establishment of time series, and facilitated comparisons with other widely used xylem anatomical features. Earlywood had significantly lower PERPAR (5.77 vs. 6.18%) and marginally fewer initiating rays than latewood. In comparison to tangential sections, PERPAR was systematically overestimated (6.50 vs. 4.92%) and required approximately twice the sample area for similar accuracy. Radial cuttings provided the least accurate PERPAR estimates. This evaluation of ray parenchyma in conifers and the presented guidelines regarding data accuracy as a function of measured wood surface and number of samples represent an important methodological reference for ray quantification, which will ultimately improve the understanding of the fundamental role of ray parenchyma tissue for the performance and survival of trees growing in stressed environments.

  12. Assessing Conifer Ray Parenchyma for Ecological Studies: Pitfalls and Guidelines

    PubMed Central

    von Arx, Georg; Arzac, Alberto; Olano, José M.; Fonti, Patrick

    2015-01-01

    Ray parenchyma is an essential tissue for tree functioning and survival. This living tissue plays a major role for storage and transport of water, nutrients, and non-structural carbohydrates (NSC), thus regulating xylem hydraulics and growth. However, despite the importance of rays for tree carbon and water relations, methodological challenges hamper knowledge about ray intra- and inter-tree variability and its ecological meaning. In this study we provide a methodological toolbox for soundly quantifying spatial and temporal variability of different ray features. Anatomical ray features were surveyed in different cutting planes (cross-sectional, tangential, and radial) using quantitative image analysis on stem-wood micro-sections sampled from 41 mature Scots pines (Pinus sylvestris). The percentage of ray surface (PERPAR), a proxy for ray volume, was compared among cutting planes and between early- and latewood to assess measurement-induced variability. Different tangential ray metrics were correlated to assess their similarities. The accuracy of cross-sectional and tangential measurements for PERPAR estimates as a function of number of samples and the measured wood surface was assessed using bootstrapping statistical technique. Tangential sections offered the best 3D insight of ray integration into the xylem and provided the most accurate estimates of PERPAR, with 10 samples of 4 mm2 showing an estimate within ±6.0% of the true mean PERPAR (relative 95% confidence interval, CI95), and 20 samples of 4 mm2 showing a CI95 of ±4.3%. Cross-sections were most efficient for establishment of time series, and facilitated comparisons with other widely used xylem anatomical features. Earlywood had significantly lower PERPAR (5.77 vs. 6.18%) and marginally fewer initiating rays than latewood. In comparison to tangential sections, PERPAR was systematically overestimated (6.50 vs. 4.92%) and required approximately twice the sample area for similar accuracy. Radial cuttings provided the least accurate PERPAR estimates. This evaluation of ray parenchyma in conifers and the presented guidelines regarding data accuracy as a function of measured wood surface and number of samples represent an important methodological reference for ray quantification, which will ultimately improve the understanding of the fundamental role of ray parenchyma tissue for the performance and survival of trees growing in stressed environments. PMID:26635842

  13. Tourniquet application after local forearm warming to improve venodilation for peripheral intravenous cannulation in young and middle-aged adults: A single-blind prospective randomized controlled trial.

    PubMed

    Yamagami, Yuki; Tomita, Kohei; Tsujimoto, Tomomi; Inoue, Tomoko

    2017-07-01

    Local forearm warming before tourniquet application is often used to promote venodilation for peripheral intravenous cannulation; however, few studies have compared the effect of tourniquet application with and without local warming on vein size. To evaluate the effectiveness of tourniquet application after local forearm warming with that of tourniquet application alone in young and middle-aged adults. A single-blind, prospective, parallel group, randomized controlled trial. A national university in Japan. Seventy-two volunteers aged 20-64 years. Participants were randomly allocated to one of two groups: tourniquet application for 30s after forearm application of a heat pack warmed to 40°C±2°C for 15min (active warming group; n=36) or tourniquet application for 30s after applying a non-warmed heat pack for 15min (passive warming group; n=36). The primary outcomes were vein cross-sectional area on the forearm, measured after the intervention by blinded research assistants using ultrasound. Secondary outcomes were shortest diameter, and longest diameter of vein on the forearm, forearm skin temperature, body temperature, pulse, systolic blood pressure, and diastolic blood pressure. All outcomes were assessed at the same site before and immediately after the intervention, once per participant. Vein cross-sectional area, shortest vein diameter, and longest vein diameter were significantly increased in the active warming group compared with the passive warming group (p <0.01). Tourniquet application after local warming was superior to tourniquet application alone in increasing vein cross-sectional, shortest diameter, and longest diameter (between-group differences of 2.2mm 2 , 0.5mm, and 0.5mm, respectively), and in raising skin temperature (between-group difference: 5.2°C). However, there were no significant differences in body temperature, pulse, or systolic or diastolic blood pressure between the groups. There were no adverse events associated with either intervention. Tourniquet application after local warming was associated with increased forearm vein size when compared with tourniquet application alone, and was demonstrated as being safe. Thus, with demonstrable effects on vein size, we recommend local warming before tourniquet application as a safe and effective technique for improving venodilation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. The rabbit costal cartilage reconstructive surgical model.

    PubMed

    Badran, Karam W; Waki, Curt; Hamamoto, Ashley; Manz, Ryan; Wong, Brian J F

    2014-02-01

    Rib grafts in facial plastic surgery are becoming more frequently used. Small animal models, although not ideal may be used to emulate costal cartilage-based procedures. A surgical characterization of this tissue will assist future research in the selection of appropriate costal segments, based on quantitative and qualitative properties. The objective of this study is to assess the surgical anatomy of the rabbit costal margin and evaluate costal cartilage for use in either in vivo or ex vivo studies and to examine reconstructive procedures. Detailed thoracic dissections of 21 New Zealand white rabbits were performed post-mortem. Costal cartilage of true, false, and floating ribs were harvested. The length, thickness, and width at proximal, medial, and distal locations of the cartilage, with perichondrium intact were measured. Further qualitative observation and digital images of curvature, flexibility, and segmental cross-sectional shape were recorded. The main outcome measure(s) is to characterize, describe, and assess the consistency of dimensions, location, and shape of costal cartilage. In this study, 12 to 13 ribs encase the thoracic cavity. Cartilage from true ribs has an average length, width, and depth of 23.75 ± 0.662, 3.02 ± 0.025, and 2.18 ± 0.018 mm, respectively. The cartilage from false ribs has an average length, width, and depth of 41.97 ± 1.48, 2.00 ± 0.07, 1.19 ± 0.03 mm, and that of floating ribs are 7.66 ± 0.29, 1.98 ± 0.04, and 0.96 ± 0.03 mm. Rib 8 is found to be the longest costal cartilage (49.10 ± 0.64 mm), with the widest and thickest at ribs 1 (3.91 ± 0.08 mm) and 6 (2.41 ± 0.11 mm), respectively. Cross-sectional segments reveal the distal cartilage to maintain an hourglass shape that broadens to become circular and eventually ovoid at the costochondral junction. The New Zealand white rabbit is a practical source of costal cartilage that is of sufficient size and reproducibility to use in surgical research where the long-term effects of operations, therapies, devices, and pharmacologic on cartilage can be studied in vivo. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. Effect of coating on properties of esthetic orthodontic nickel-titanium wires.

    PubMed

    Iijima, Masahiro; Muguruma, Takeshi; Brantley, William; Choe, Han-Cheol; Nakagaki, Susumu; Alapati, Satish B; Mizoguchi, Itaru

    2012-03-01

    To determine the effect of coating on the properties of two esthetic orthodontic nickel-titanium wires. Woowa (polymer coating; Dany Harvest) and BioForce High Aesthetic Archwire (metal coating; Dentsply GAC) with cross-section dimensions of 0.016 × 0.022 inches were selected. Noncoated posterior regions of the anterior-coated Woowa and uncoated Sentalloy were used for comparison. Nominal coating compositions were determined by x-ray fluorescence (JSX-3200, JOEL). Cross-sectioned and external surfaces were observed with a scanning electron microscope (SEM; SSX-550, Shimadzu) and an atomic force microscope (SPM-9500J2, Shimadzu). A three-point bending test (12-mm span) was carried out using a universal testing machine (EZ Test, Shimadzu). Hardness and elastic modulus of external and cross-sectioned surfaces were obtained by nanoindentation (ENT-1100a, Elionix; n  =  10). Coatings on Woowa and BioForce High Aesthetic Archwire contained 41% silver and 14% gold, respectively. The coating thickness on Woowa was approximately 10 µm, and the coating thickness on BioForce High Aesthetic Archwire was much smaller. The surfaces of both coated wires were rougher than the noncoated wires. Woowa showed a higher mean unloading force than the noncoated Woowa, although BioForce High Aesthetic Archwire showed a lower mean unloading force than Sentalloy. While cross-sectional surfaces of all wires had similar hardness and elastic modulus, values for the external surface of Woowa were smaller than for the other wires. The coating processes for Woowa and BioForce High Aesthetic Archwire influence bending behavior and surface morphology.

  16. Mach-Zehnder Interferometer Biochemical Sensor Based on Silicon-on-Insulator Rib Waveguide with Large Cross Section

    PubMed Central

    Yuan, Dengpeng; Dong, Ying; Liu, Yujin; Li, Tianjian

    2015-01-01

    A high-sensitivity Mach-Zehnder interferometer (MZI) biochemical sensing platform based on Silicon-in-insulator (SOI) rib waveguide with large cross section is proposed in this paper. Based on the analyses of the evanescent field intensity, the mode polarization and cross section dimensions of the SOI rib waveguide are optimized through finite difference method (FDM) simulation. To realize high-resolution MZI read-out configuration based on the SOI rib waveguide, medium-filled trenches are employed and their performances are simulated through two-dimensional finite-difference-time domain (2D-FDTD) method. With the fundamental EH-polarized mode of the SOI rib waveguide with a total rib height of 10 μm, an outside rib height of 5 μm and a rib width of 2.5 μm at the operating wavelength of 1550 nm, when the length of the sensitive window in the MZI configuration is 10 mm, a homogeneous sensitivity of 7296.6%/refractive index unit (RIU) is obtained. Supposing the resolutions of the photoelectric detectors connected to the output ports are 0.2%, the MZI sensor can achieve a detection limit of 2.74 × 10−6 RIU. Due to high coupling efficiency of SOI rib waveguide with large cross section with standard single-mode glass optical fiber, the proposed MZI sensing platform can be conveniently integrated with optical fiber communication systems and (opto-) electronic systems, and therefore has the potential to realize remote sensing, in situ real-time detecting, and possible applications in the internet of things. PMID:26343678

  17. A comparison of two reciprocating instruments using bending stress and cyclic fatigue tests.

    PubMed

    Scelza, Pantaleo; Harry, Davidowicz; Silva, Licinio Esmeraldo da; Barbosa, Igor Bastos; Scelza, Miriam Zaccaro

    2015-01-01

    The aim of this study was to comparatively evaluate the bending resistance at 45º, the static and dynamic cyclic fatigue life, and the fracture type of the WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) 25-08 and Reciproc (VDW, Munich, Germany) 25-08 instruments. A total of 60 nickel-titanium (NiTi) instruments (30 Reciproc and 30 WaveOne) from three different lots, each of which was 25 mm in length, were tested. The bending resistance was evaluated through the results of a cantilever-bending test conducted using a universal testing machine. Static and dynamic cyclic fatigue testing was conducted using a custom-made device. For the static and dynamic tests, a cast Ni-Cr-Mo-Ti alloy metal block with an artificial canal measuring 1.77 mm in diameter and 20.00 mm in total length was used. A scanning electron microscope was used to determine the type of fracture. Statistical analyses were performed on the results. The WaveOne instrument was less flexible than the Reciproc (p < 0.05). The Reciproc instrument showed better resistance in the static and dynamic cyclic fatigue tests (p < 0.05). The transverse cross-section and geometry of the instruments were important factors in their resistance to bending and cyclic fracture. Both of the instruments showed ductile-type fracture characteristics. It can be concluded that the Reciproc 25-08 instrument was more resistant to static and dynamic cyclic fatigue than the WaveOne 25-08 instrument, while the WaveOne 25-08 instrument was less flexible. Bending and resistance to cyclic fracture were influenced by the instruments' geometries and transverse cross-sections. Both of the instruments showed ductile-type fracture characteristics.

  18. Size at birth and blood pressure: cross sectional study in 8-11 year old children.

    PubMed Central

    Taylor, S. J.; Whincup, P. H.; Cook, D. G.; Papacosta, O.; Walker, M.

    1997-01-01

    OBJECTIVE: To identify which patterns of fetal growth, represented by different measurements of size at birth, are associated with increased blood pressure in children aged 8-11 years. DESIGN AND SETTING: School based, cross sectional survey conducted in 10 towns in England and Wales in 1994. SUBJECTS: 3010 singleton children (response rate 75%) with physical measurements and information on birth weight from parental questionnaires. Hospital birth records were examined for 1573. MAIN OUTCOME MEASURES: Systolic and diastolic blood pressure at age 8-11 years. RESULTS: In the whole group birth weight was inversely related to systolic pressure (regression coefficient -1.48 mm Hg/kg; 95% confidence interval -2.20 to -0.76) after adjustment for current body size. There was no significant association between birth weight and diastolic pressure. The association with systolic pressure was much stronger in girls (-2.54 mm Hg/kg; -3.60 to -1.48) than in boys (-0.64 mm Hg/kg; -1.58 to 0.30), with a significant difference between the sexes (P = 0.006). Among the other neonatal measures, head circumference and placental weight were inversely associated with subsequent blood pressure in girls, and placental ratio (placental weight:birth weight) was positively associated with blood pressure in boys. Neither ponderal index at birth nor length:head circumference ratio was related to blood pressure in either sex. CONCLUSIONS: In these contemporary children the association between birth weight and blood pressure was apparent only in girls. There was no evidence that measures of size at birth, which may be related to nutrition at critical periods of pregnancy (thinness at birth or shortness in relation to head circumference), are related to blood pressure in the offspring. PMID:9056797

  19. Maintenance of myonuclear domain size in rat soleus after overload and growth hormone/IGF-I treatment

    NASA Technical Reports Server (NTRS)

    McCall, G. E.; Allen, D. L.; Linderman, J. K.; Grindeland, R. E.; Roy, R. R.; Mukku, V. R.; Edgerton, V. R.

    1998-01-01

    The purpose of this study was to determine the effects of functional overload (FO) combined with growth hormone/insulin-like growth factor I (GH/IGF-I) administration on myonuclear number and domain size in rat soleus muscle fibers. Adult female rats underwent bilateral ablation of the plantaris and gastrocnemius muscles and, after 7 days of recovery, were injected three times daily for 14 days with GH/IGF-I (1 mg/kg each; FO + GH/IGF-I group) or saline vehicle (FO group). Intact rats receiving saline vehicle served as controls (Con group). Muscle wet weight was 32% greater in the FO than in the Con group: 162 +/- 8 vs. 123 +/- 16 mg. Muscle weight in the FO + GH/IGF-I group (196 +/- 14 mg) was 59 and 21% larger than in the Con and FO groups, respectively. Mean soleus fiber cross-sectional area of the FO + GH/IGF-I group (2,826 +/- 445 microm2) was increased compared with the Con (2,044 +/- 108 microm2) and FO (2,267 +/- 301 microm2) groups. The difference in fiber size between the FO and Con groups was not significant. Mean myonuclear number increased in FO (187 +/- 15 myonuclei/mm) and FO + GH/IGF-I (217 +/- 23 myonuclei/mm) rats compared with Con (155 +/- 12 myonuclei/mm) rats, although the difference between FO and FO + GH/IGF-I animals was not significant. The mean cytoplasmic volume per myonucleus (myonuclear domain) was similar across groups. These results demonstrate that the larger mean muscle weight and fiber cross-sectional area occurred when FO was combined with GH/IGF-I administration and that myonuclear number increased concomitantly with fiber volume. Thus there appears to be some mechanism(s) that maintains the myonuclear domain when a fiber hypertrophies.

  20. The morphological substrate for Renal Denervation: Nerve distribution patterns and parasympathetic nerves. A post-mortem histological study.

    PubMed

    van Amsterdam, Wouter A C; Blankestijn, Peter J; Goldschmeding, Roel; Bleys, Ronald L A W

    2016-03-01

    Renal Denervation as a possible treatment for hypertension has been studied extensively, but knowledge on the distribution of nerves surrounding the renal artery is still incomplete. While sympathetic and sensory nerves have been demonstrated, there is no mention of the presence of parasympathetic nerve fibers. To provide a description of the distribution patterns of the renal nerves in man, and, in addition, provide a detailed representation of the relative contribution of the sympathetic, parasympathetic and afferent divisions of the autonomic nervous system. Renal arteries of human cadavers were each divided into four longitudinal segments and immunohistochemically stained with specific markers for afferent, parasympathetic and sympathetic nerves. Nerve fibers were semi-automatically quantified by computerized image analysis, and expressed as cross-sectional area relative to the distance to the lumen. A total of 3372 nerve segments were identified in 8 arteries of 7 cadavers. Sympathetic, parasympathetic and afferent nerves contributed for 73.5% (95% CI: 65.4-81.5%), 17.9% (10.7-25.1%) and 8.7% (5.0-12.3%) of the total cross-sectional nerve area, respectively. Nerves are closer to the lumen in more distal segments and larger bundles that presumably innervate the kidney lie at 1-3.5mm distance from the lumen. The tissue-penetration depth of the ablation required to destroy 50% of the nerve fibers is 2.37 mm in the proximal segment and 1.78 mm in the most distal segments. Sympathetic, parasympathetic and afferent nerves exist in the vicinity of the renal artery. The results warrant further investigation of the role of the parasympathetic nervous system on renal physiology, and may contribute to refinement of the procedure by focusing the ablation on the most distal segment. Copyright © 2015 Elsevier GmbH. All rights reserved.

  1. Tensile properties of the transverse carpal ligament and carpal tunnel complex.

    PubMed

    Ugbolue, Ukadike C; Gislason, Magnus K; Carter, Mark; Fogg, Quentin A; Riches, Philip E; Rowe, Philip J

    2015-08-01

    A new sophisticated method that uses video analysis techniques together with a Maillon Rapide Delta to determine the tensile properties of the transverse carpal ligament-carpal tunnel complex has been developed. Six embalmed cadaveric specimens amputated at the mid-forearm and aged (mean (SD)): 82 (6.29) years were tested. The six hands were from three males (four hands) and one female (two hands). Using trigonometry and geometry the elongation and strain of the transverse carpal ligament and carpal arch were calculated. The cross-sectional area of the transverse carpal ligament was determined. Tensile properties of the transverse carpal ligament-carpal tunnel complex and Load-Displacement data were also obtained. Descriptive statistics, one-way ANOVA together with a post-hoc analysis (Tukey) and t-tests were incorporated. A transverse carpal ligament-carpal tunnel complex novel testing method has been developed. The results suggest that there were no significant differences between the original transverse carpal ligament width and transverse carpal ligament at peak elongation (P=0.108). There were significant differences between the original carpal arch width and carpal arch width at peak elongation (P=0.002). The transverse carpal ligament failed either at the mid-substance or at their bony attachments. At maximum deformation the peak load and maximum transverse carpal ligament displacements ranged from 285.74N to 1369.66N and 7.09mm to 18.55mm respectively. The transverse carpal ligament cross-sectional area mean (SD) was 27.21 (3.41)mm(2). Using this method the results provide useful biomechanical information and data about the tensile properties of the transverse carpal ligament-carpal tunnel complex. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Novel Three-Dimensional Understanding of Maxillary Cleft Distraction.

    PubMed

    Vaughan, Stephen Michael; Kau, Chung How; Waite, Peter Daniel

    2016-09-01

    To set forth a universal standard methodology for quantifying volumetric and linear changes in the craniofacial complex, utilizing three-dimensional data captured from a cleft-lip palate patient who underwent rigid external device (RED) distraction. Cone beam computed tomography images of a 14-year-old patient were captured using a Kodak 9500 (Atlanta, GA) Cone Beam system device and a stereophotogrammetric system (3dMDface(TM) Atlanta, GA). The subject was a nonsyndromic unilateral cleft-lip palate patient who received RED distraction as part of maxillary advancement in conjunction with orthodontic treatment. Preop (T1) and postop (T2) images were superimposed using Invivo 5.2.3 (San Jose, CA) software. Volumetric rendering of the airway, bone, and soft tissues, as well as linear measurements were analyzed. Each measurement was captured 10 times to ensure reliability and reproducibility of methodology. Data from T1 to T2 revealed mean differences as follows: airway total volume +5250 mm, minimum cross-sectional area +67.84 mm; bone +1719 mm, soft tissue +44,432 mm. Mean of linear measurements: Pronasale 1.98 mm, Subnasale 3.35 mm, Labial superius 10.79 mm, Labial inferius 4.13 mm, Right alare 5.71 mm, Right cheilion 7.83 mm, Left alare 4.97 mm, Left cheilion 5.50 mm, Pogonion 3.01 mm, B-point 2.49 mm, U1-U1 9.77 mm, and L1-L1 0.00 mm. P values are <0.001 for each analysis. This paper represents a novel and innovative way to look at prepost RED distractions in a three-dimensional format. A universal standard analysis of the craniofacial complex can be implemented using the techniques and method outlined in this study.

  3. Damage analysis of CF/AF hybrid fabric reinforced plastic laminated composites with scanned image microscopy

    NASA Astrophysics Data System (ADS)

    Miyasaka, Chiaki; Kasano, Hideaki; Shull, Peter J.

    2004-07-01

    The article presents an experimental study that has been conducted to evaluate the impact loading damage within hybrid fabric laminates-carbon and Aramid fibers. The experiments have been undertaken on a series of interply hybrid specimens with different preprags stacking sequences. Impact damage was created using an air-gun like impact device propelling spherical steel balls with diameters of 5.0mm and 10.0mm and having velocities of 113m/s and 40m/s respectively. The resulting specimen surface and internal damage (e.g., micro-cracking and debonding) was visualized nondestructively by a scanning acoustic microscope (SAM) while further interrogation of specific internal damage was visualized using a scanning electron microscope (SEM) on cross-sectioned panels.

  4. Topographic relationship between root apex of mesially and horizontally impacted mandibular third molar and lingual plate: cross-sectional analysis using CBCT

    PubMed Central

    Wang, Dongmiao; He, Xiaotong; Wang, Yanling; Zhou, Guangchao; Sun, Chao; Yang, Lianfeng; Bai, Jianling; Gao, Jun; Wu, Yunong; Cheng, Jie

    2016-01-01

    The present study was aimed to determine the topographic relationship between root apex of the mesially and horizontally impacted mandibular third molar and lingual plate of mandible. The original cone beam computed tomography (CBCT) data of 364 teeth from 223 patients were retrospectively collected and analyzed. The topographic relationship between root apex and lingual plate on cross-sectional CBCT images was classified as non-contact (99), contact (145) and perforation (120). The cross-sectional morphology of lingual plate at the level of root apex was defined as parallel (28), undercut (38), slanted (29) and round (4). The distribution of topographic relationship between root apex and lingual plate significantly associated with gender, impaction depth, root number and lingual plate morphology. Moreover, the average bone thickness of lingual cortex and distance between root apex and the outer surface of lingual plate were 1.02 and 1.39 mm, respectively. Furthermore, multivariate regression analyses identified impaction depth and lingual plate morphology as the risk factors for the contact and perforation subtypes between root apex and lingual plate. Collectively, our findings reveal the topographic proximity of root apex of impacted mandibular third molar to the lingual plate, which might be associated with intraoperative and postoperative complications during tooth extraction. PMID:27991572

  5. Experimental studies on tungsten-armour impact on nuclear responses of solid breeding blanket

    NASA Astrophysics Data System (ADS)

    Sato, Satoshi; Nakao, Makoto; Verzilov, Yury; Ochiai, Kentaro; Wada, Masayuki; Kubota, Naoyoshi; Kondo, Keitaro; Yamauchi, Michinori; Nishitani, Takeo

    2005-07-01

    In order to experimentally evaluate the tungsten armour impact on tritium production of the solid breeding blanket being developed by JAERI for tokamak-type DEMO reactors, neutronics integral experiments have been performed using DT neutrons at the Fusion Neutron Source facility of JAERI. Solid breeding blanket mockups relevant to the DEMO blanket have been applied in this study. The mockups are made of a set of layers consisting of 0-25.2 mm thick tungsten, 16 mm thick F82H, 12 mm thick Li2TiO3 and 100-200 mm thick beryllium with a cross-section of 660 × 660 mm in maximum. Pellets of Li2CO3 are embedded in the Li2TiO3 layers to measure the tritium production rate. By installing the 5 mm, 12.6 mm and 25.2 mm thick tungsten armours, the sum of the integrated tritium productions at the pellets are reduced by about 2.1%, 2.5% and 6.1% relative to the case without the armour, respectively. Numerical calculations have been conducted using the Monte Carlo code. In the case of the mockups with the tungsten armour, calculation results for the sum of the integrated tritium productions agree well with the experimental data within 4% and 19% in the experiments without and with a neutron reflector, respectively.

  6. Dimensional changes of upper airway after rapid maxillary expansion: a prospective cone-beam computed tomography study.

    PubMed

    Chang, Yoon; Koenig, Lisa J; Pruszynski, Jessica E; Bradley, Thomas G; Bosio, Jose A; Liu, Dawei

    2013-04-01

    The aim of this prospective study was to use cone-beam computed tomography to assess the dimensional changes of the upper airway in orthodontic patients with maxillary constriction treated by rapid maxillary expansion. Fourteen orthodontic patients (mean age, 12.9 years; range, 9.7-16 years) were recruited. The patients with posterior crossbite and constricted maxilla were treated with rapid maxillary expansion as the initial part of their comprehensive orthodontic treatments. Before and after rapid maxillary expansion cone-beam computed tomography scans were taken to measure the retropalatal and retroglossal airway changes in terms of volume, and sagittal and cross-sectional areas. The transverse expansions by rapid maxillary expansion were assessed between the midlingual alveolar bone plates at the maxillary first molar and first premolar levels. The measurements of the before and after rapid maxillary expansion scans were compared by using paired t tests with the Bonferroni adjustment for multiple comparisons. After rapid maxillary expansion, significant and equal amounts of 4.8 mm of expansion were observed at the first molar (P = 0.0000) and the first premolar (P = 0.0000) levels. The width increase at the first premolar level (20.0%) was significantly greater than that at the first molar level (15.0%) (P = 0.035). As the primary outcome variable, the cross-sectional airway measured from the posterior nasal spine to basion level was the only parameter showing a significant increase of 99.4 mm(2) (59.6%) after rapid maxillary expansion (P = 0.0004). These results confirm the findings of previous studies of the effect of rapid maxillary expansion on the maxilla. Additionally, we found that only the cross-sectional area of the upper airway at the posterior nasal spine to basion level significantly gains a moderate increase after rapid maxillary expansion. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  7. Bull’s-Eye Structure with a Sub-Wavelength Circular Aperture

    DTIC Science & Technology

    2013-08-30

    experimentation. Bull’s-eye structures were fabricated with high precision using a CNC lathe machine and a thermal evaporator. Then, quality of...periodic grooves in the 3-mm-wavelength bull’s-eye structure were created with a CNC lathe on a Teflon or high-density polyethylene (HDPE) substrate... CNC lathe . Figure 26 (far right) shows the cross section of the bull’s-eye structure with six periodic grooves. By clicking on “Preferences” in

  8. High resolution transbulbar sonography in children with suspicion of increased intracranial pressure.

    PubMed

    Steinborn, Marc; Friedmann, Melanie; Makowski, Christine; Hahn, Helmut; Hapfelmeier, Alexander; Juenger, Hendrik

    2016-04-01

    To evaluate the accuracy of high resolution transbulbar sonography for the estimation of intracranial pressure (ICP) in children. In children and adolescents with acute neurologic symptoms of various origin, transbulbar sonography was performed. Besides measurement of the optic nerve sheath diameter (ONSD), the ultrastructure of the subarachnoid space of the optic nerve sheath was evaluated. The results of transbulbar sonography were correlated with clinical data based on cross-sectional imaging, ICP measurement, and ophthalmologic examination. Eighty-one patients (age 3-17.8 years, mean 11.7 years) were included. In 25 children, cross-sectional imaging and ICP measurement revealed increased intracranial pressure. The mean ONSD was 6.85 ± 0.81 mm. Twenty patients (20/25, 80 %) had a microcystic appearance of the subarachnoid space of the optic nerve. In 56 children without evidence of increased intracranial pressure, the mean ONSD was 5.77 ± 0.48 mm. Forty-nine patients (49/56, 87.5 %) had a normal homogenous appearance of the subarachnoid space. The ONSD in children with increased intracranial pressure was significantly higher than in patients without (p < 0.001). High resolution transbulbar sonography of the optic nerve is a useful technique for the rapid and non-invasive estimation of intracranial pressure in children. Besides measurement of the optic nerve sheath diameter, evaluation of the ultrastructure of the subarachnoid space of the optic nerve is a helpful parameter.

  9. Optic nerve size evaluated by magnetic resonance imaging in children with optic nerve hypoplasia, multiple pituitary hormone deficiency, isolated growth hormone deficiency, and idiopathic short stature.

    PubMed

    Birkebaek, Niels Holtum; Patel, Leena; Wright, Neville Bryce; Grigg, John Russell; Sinha, Smeeta; Hall, Catherine Margaret; Price, David Anthony; Lloyd, Ian Christopher; Clayton, Peter Ellis

    2004-10-01

    To objectively define criteria for intracranial optic nerve (ON) size in ON hypoplasia (ONH) on magnetic resonance imaging (MRI) scans. Intracranial ON sizes from MRI were compared between 46 children with ONH diagnosed by ophthalmoscopy (group 1, isolated ONH, 8 children; and group 2, ONH associated with abnormalities of the hypothalamic-pituitary axis and septum pellucidum, 38 children) and children with multiple pituitary hormone deficiency (group 3, multiple pituitary hormone deficiency, 14 children), isolated growth hormone deficiency (group 4, isolated growth hormone deficiency, 15 children), and idiopathic short stature (group 5, idiopathic short stature, 10 children). Intracranial ON size was determined by the cross-sectional area, calculated as [pi x (1/2) height x (1/2) width]. Groups 1 and 2 had lower intracranial ON size than did groups 3, 4, and 5 (P < .001). No patients in groups 3 through 5 who had MRI after 12 months of age (when 95% adult size of ONs is attained) had ONs <2.9 mm 2 . Visual acuity correlated significantly with ON size (P < .01). Magnetic resonance imaging of the ONs with cross-sectional area <2.9 mm 2 in a short child more than 12 months of age, with or without hypothalamic-pituitary axis abnormalities, confirms the clinical diagnosis of ONH.

  10. Analysis of mandibular second molars with fused roots and shallow radicular grooves by using micro-computed tomography.

    PubMed

    Amoroso-Silva, Pablo; De Moraes, Ivaldo Gomes; Marceliano-Alves, Marilia; Bramante, Clovis Monteiro; Zapata, Ronald Ordinola; Hungaro Duarte, Marco Antonio

    2018-01-01

    This study aimed to describe the morphological and morphometric aspects of fused mandibular second molars with radicular shallow grooves using micro-computed tomography (CT). Eighty-eight mandibular second molars with fused roots were scanned in a micro-CT scanner at a voxel size of 19.6 μm. After reconstruction, only molars without C-shaped roots and presenting shallow radicular grooves were selected. 30 molars were chosen for further analysis. Canal cross-sections were classified according to Fan's modified classification (C1, C2, C3, and C4) and morphometric parameters at the apical region, examination of accessory foramina and tridimensional configuration were evaluated. Three-dimensional reconstructions indicated a higher prevalence of merging type ( n = 22). According to Fan's modified classification, the C4 configuration was predominant in the 3 apical mm. Roundness median values revealed a more round-shaped canals at 3 mm (0.72) than at 2 (0.63) and 1 (0.61) mm from the apex. High values of major and minor diameters were observed in the canals of these evaluated sections. In addition, few accessory apical foramina were observed at 1 and 2 mm from the apex. The average distance between last accessory foramina and the anatomic apex was 1.17 mm. A less complex internal anatomy is found when a mandibular second molar presents fused roots with shallow radicular grooves. The merging type canal was frequently observed. Moreover, the C4 configuration was predominant at a point 3 mm from the apex and presented rounded canals, large apical diameters, and few accessory foramina. The cervical and middle thirds presented C3 and C1 canal configurations most frequently. A minor morphological complexity is found when fused mandibular second molars present shallow radicular grooves.

  11. Comparative evaluation of the cadaveric and computed tomographic features of the coelomic cavity in the green iguana (Iguana iguana), black and white tegu (Tupinambis merianae) and bearded dragon (Pogona vitticeps).

    PubMed

    Banzato, T; Selleri, P; Veladiano, I A; Zotti, A

    2013-12-01

    Contrast-enhanced computed tomographic studies of the coelomic cavity in four green iguanas, four black and white tegus and four bearded dragons were performed using a conventional CT scanner. Anatomical reference cross sections were obtained from four green iguana, four black and white tegu and six bearded dragon cadavers; the specimens were stored in a -20°C freezer for 24 h then sliced into 5-mm intervals. The frozen sections were cleaned with water and photographed on both sides. The individual anatomical structures were identified by means of the available literature; these were labelled first on the anatomical images and then matched to the corresponding computed tomography images. The results provide an atlas of the normal cross-sectional and computed tomographic anatomy of the coelomic cavity in the green iguana, the black and white tegu and the bearded dragon, which is useful in the interpretation of any imaging modality. © 2013 Blackwell Verlag GmbH.

  12. On the Solidification and Structure Formation during Casting of Large Inserts in Ferritic Nodular Cast Iron

    NASA Astrophysics Data System (ADS)

    Tadesse, Abel; Fredriksson, Hasse

    2018-06-01

    The graphite nodule count and size distributions for boiling water reactor (BWR) and pressurized water reactor (PWR) inserts were investigated by taking samples at heights of 2160 and 1150 mm, respectively. In each cross section, two locations were taken into consideration for both the microstructural and solidification modeling. The numerical solidification modeling was performed in a two-dimensional model by considering the nucleation and growth in eutectic ductile cast iron. The microstructural results reveal that the nodule size and count distribution along the cross sections are different in each location for both inserts. Finer graphite nodules appear in the thinner sections and close to the mold walls. The coarser nodules are distributed mostly in the last solidified location. The simulation result indicates that the finer nodules are related to a higher cooling rate and a lower degree of microsegregation, whereas the coarser nodules are related to a lower cooling rate and a higher degree of microsegregation. The solidification time interval and the last solidifying locations in the BWR and PWR are also different.

  13. Maturity- and sex-related changes in tibial bone geometry, strength and bone-muscle strength indices during growth: a 20-month pQCT study.

    PubMed

    Macdonald, Heather M; Kontulainen, Saija A; Mackelvie-O'Brien, Kerry J; Petit, Moira A; Janssen, Patricia; Khan, Karim M; McKay, Heather A

    2005-06-01

    During growth, bone strength is conferred through subtle adaptations in bone mass and geometry in response to muscle forces. Few studies have examined the changes in bone geometry, strength and the bone-muscle strength relationship across maturity in boys and girls. Our aims were to describe (i) 20-month changes in bone geometry and strength at the tibial midshaft across three maturity groups of boys and girls, (ii) differences in these adaptations between sexes at the same approximate level of maturity and (iii) the bone-muscle strength relationship across maturity groups of boys and girls and between sexes. We used peripheral quantitative computed tomography (pQCT, Stratec XCT-2000) to measure change in total bone cross-sectional area (ToA, mm(2)), cortical area (CoA, mm(2)), average cortical thickness (C.Th., mm), section modulus (mm(3)) and muscle cross-sectional area (mm(2)) at the tibial midshaft (50% site) in 128 EARLY-, PERI- and POST-pubertal girls (n = 69, 11.9 +/- 0.6 years) and boys (n = 59, 12.0 +/- 0.6 years) across 20 months. We also calculated two bone-muscle strength indices (BMSI) for compression (CoA/MCSA) and bending [strength index/MCSA; where strength index = Z / (tibial length / 2)]. EARLY boys and girls had smaller ToA at baseline than same sex PERI or POST participants. There were no sex differences in ToA or CoA at baseline; however, boys increased both parameters significantly more than girls in every maturity group (8.5-11.1%, P < 0.01). These changes in bone geometry conferred greater gains in bone strength for boys compared with girls in each maturity group (13.8-15.6%, P < 0.01). Baseline BMSIs did not differ between sexes for EARLY and PERI groups, whereas BMSIs were significantly higher for POST boys compared with POST girls (P < 0.05). BMSIs decreased for EARLY and PERI girls (-7.4-(-1.1%)) whereas the ratios remained stable for EARLY and PERI boys (-0.6-2.5%). This sex difference in BMSI change was due to a relatively greater increase in CoA among EARLY and PERI boys compared with same-maturity girls. BMSIs remained stable in POST girls and decreased in POST boys due to relatively greater gains in MCSA. This study provides novel longitudinal descriptions of the maturity- and sex-specific changes in bone geometry, strength and bone-muscle strength indices.

  14. Atomization of liquids in a Pease-Anthony Venturi scrubber. Part II. Droplet dispersion.

    PubMed

    Gonçalves, J A S; Costa, M A M; Aguiar, M L; Coury, J R

    2004-12-10

    Droplet distribution is of fundamental importance to the performance of a Venturi scrubber. Ensuring good liquid distribution can increase performance at minimal liquid usage. In this study, droplet dispersion in a rectangular Pease-Anthony Venturi scrubber, operating horizontally, was examined both theoretically and experimentally. The Venturi throat cross-section was 24 mm x 35 mm, and the throat length varied from 63 to 140 mm. Liquid was injected through a single orifice (1.0 mm diameter) on the throat wall. This arrangement allowed the study of the influence of jet penetration on droplet distribution. Gas velocity at the throat was 58.3 and 74.6 m/s, and the liquid flow rate was 286, 559 and 853 ml/min. A probe with a 2.7 mm internal diameter was used to isokinetically remove liquid from several positions inside the equipment. It was possible to study liquid distribution close to the injection point. A new model for droplet dispersion, which incorporates the new description of the jet atomization process developed by the present authors in the first article of this series, is proposed and evaluated. The model predicted well the experimental data.

  15. Effects of blood contamination on resin-resin bond strength.

    PubMed

    Eiriksson, Sigurdur O; Pereira, Patricia N R; Swift, Edward J; Heymann, Harald O; Sigurdsson, Asgeir

    2004-02-01

    Incremental placement and curing of resin composites has been recommended. However, this requires longer operating time, and therefore, increased risk of contamination. The purpose of this study was to evaluate the effects of blood contamination on microtensile bond strengths (microTBS) between resin interfaces and to determine the best decontamination method to re-establish the original resin-resin bond strength. The top surfaces of 64, 4-mm composite blocks (Z-250, Renew, APX, Pertac II) were untreated as the control, or were treated as follows: blood applied and dried on the surface (Treatment 1), blood applied, rinsed, dried (Treatment 2), blood applied, rinsed, and an adhesive applied (Single Bond, One-Step, Clearfil SE, Prompt L-Pop) (Treatment 3). Fresh composite was applied and light-cured in 2-mm increments. After 24 h storage in water, the specimens were sectioned into 0.7-mm thick slabs, trimmed to a cross-sectional area of 1 mm(2), and loaded to failure at a crosshead speed of 1 mm/min using an Instron universal testing machine. Data were analyzed using two-way ANOVA and Fisher's PLSD test (p<0.05). Control values ranged from 45.1 MPa for Pertac II to 71.5 MPa for APX. Untreated blood contamination resulted in resin-resin bond strengths of only 1.0-13.1 MPa. Rinsing raised bond strengths to over 40 MPa for each material. Use of an adhesive further increased bond strengths except for Pertac II. Rinsing blood from contaminated surfaces increases the resin-resin bond strength significantly and the application of an appropriate adhesive increases the bond strength to control levels.

  16. Experimental Study on Full-Scale Beams Made by Reinforced Alkali Activated Concrete Undergoing Flexure.

    PubMed

    Monfardini, Linda; Minelli, Fausto

    2016-08-30

    Alkali Activated Concrete (AAC) is an alternative kind of concrete that uses fly ash as a total replacement of Portland cement. Fly ash combined with alkaline solution and cured at high temperature reacts to form a binder. Four point bending tests on two full scale beams made with AAC are described in this paper. Companion small material specimens were also casted with the aim of properly characterizing this new tailored material. The beam's length was 5000 mm and the cross section was 200 mm × 300 mm. The AAC consisted of fly ash, water, sand 0-4 mm and coarse aggregate 6-10 mm; and the alkaline solution consisted of sodium hydroxide mixed with sodium silicate. No cement was utilized. The maximum aggregate size was 10 mm; fly ash was type F, containing a maximum calcium content of 2%. After a rest period of two days, the beam was cured at 60 °C for 24 h. Data collected and critically discussed included beam deflection, crack patterns, compressive and flexural strength and elastic modulus. Results show how AAC behavior is comparable with Ordinary Portland Cement (OPC) based materials. Nonlinear numerical analyses are finally reported, promoting a better understanding of the structural response.

  17. Experimental Study on Full-Scale Beams Made by Reinforced Alkali Activated Concrete Undergoing Flexure

    PubMed Central

    Monfardini, Linda; Minelli, Fausto

    2016-01-01

    Alkali Activated Concrete (AAC) is an alternative kind of concrete that uses fly ash as a total replacement of Portland cement. Fly ash combined with alkaline solution and cured at high temperature reacts to form a binder. Four point bending tests on two full scale beams made with AAC are described in this paper. Companion small material specimens were also casted with the aim of properly characterizing this new tailored material. The beam’s length was 5000 mm and the cross section was 200 mm × 300 mm. The AAC consisted of fly ash, water, sand 0–4 mm and coarse aggregate 6–10 mm; and the alkaline solution consisted of sodium hydroxide mixed with sodium silicate. No cement was utilized. The maximum aggregate size was 10 mm; fly ash was type F, containing a maximum calcium content of 2%. After a rest period of two days, the beam was cured at 60 °C for 24 h. Data collected and critically discussed included beam deflection, crack patterns, compressive and flexural strength and elastic modulus. Results show how AAC behavior is comparable with Ordinary Portland Cement (OPC) based materials. Nonlinear numerical analyses are finally reported, promoting a better understanding of the structural response. PMID:28773861

  18. Claw length recommendations for dairy cow foot trimming

    PubMed Central

    Archer, S. C.; Newsome, R.; Dibble, H.; Sturrock, C. J.; Chagunda, M. G. G.; Mason, C. S.; Huxley, J. N.

    2015-01-01

    The aim was to describe variation in length of the dorsal hoof wall in contact with the dermis for cows on a single farm, and hence, derive minimum appropriate claw lengths for routine foot trimming. The hind feet of 68 Holstein-Friesian dairy cows were collected post mortem, and the internal structures were visualised using x-ray µCT. The internal distance from the proximal limit of the wall horn to the distal tip of the dermis was measured from cross-sectional sagittal images. A constant was added to allow for a minimum sole thickness of 5 mm and an average wall thickness of 8 mm. Data were evaluated using descriptive statistics and two-level linear regression models with claw nested within cow. Based on 219 claws, the recommended dorsal wall length from the proximal limit of hoof horn was up to 90 mm for 96 per cent of claws, and the median value was 83 mm. Dorsal wall length increased by 1 mm per year of age, yet 85 per cent of the null model variance remained unexplained. Overtrimming can have severe consequences; the authors propose that the minimum recommended claw length stated in training materials for all Holstein-Friesian cows should be increased to 90 mm. PMID:26220848

  19. Improvement of arterial oxygenation in free-ranging moose (Alces alces) immobilized with etorphine-acepromazine-xylazine.

    PubMed

    Lian, Marianne; Evans, Alina L; Bertelsen, Mads F; Fahlman, Åsa; Haga, Henning A; Ericsson, Göran; Arnemo, Jon M

    2014-08-15

    The effect of intranasal oxygen and/or early reversal of xylazine with atipamezole on arterial oxygenation in free-ranging moose (Alces alces) immobilized with etorphine-acepromazine-xylazine with a cross-sectional clinical study on 33 adult moose was evaluated. Before treatment the mean±SD (range) partial pressure of arterial oxygen (PaO2) was 62±17 (26-99) mmHg. Twenty-six animals had a PaO2<80 mmHg. Ten had a PaO2 of 40-60 mmHg and three animals had a PaO2<40 mmHg. Intranasal oxygen and intravenous administration of atipamezole significantly increased the mean PaO2, as did the combination of the two. In contrast, atipamezole administered intramuscularly at the evaluated dose had no significant effect on arterial oxygenation. This study shows that intranasal oxygen effectively improved arterial oxygenation in immobilized moose, and that early intravenous reversal of the sedative component, in this case xylazine, in an opioid-based immobilization drug-protocol significantly improves arterial oxygenation.

  20. Remarks on Ship Model Testing, Facilities, and Test Results. The Eighth David W. Taylor Lectures

    DTIC Science & Technology

    1984-02-01

    AND TEST RESULTS 5. TYPE OF REPORT ft PERIOD COVERED Final S . PERFORMING ORG. REPORT NUMBER 7. AUTHORfsj Hans Edstrand 8...Continue on reverse aide If necessary and Identify by block number) DD 1 JAN*73 1473 EDITION OF I NOV 65 IS OBSOLETE S /N 0102-LF-014-6601...Content % —. The Curves Give the Cavitation Point Observed in a Glass a s Nozzle with 1 mm Cross Section at Different Water Temperatures. 58 44

  1. Mathematical Simulation of the Cardiopulmonary System

    DTIC Science & Technology

    1979-12-01

    assumption affected only the dicrotic notch and had negligible effects (R5 mm Hg) on the rest of the arterial pulse in modeling a passive, supine position...resistance factors , R and R’, are dependent on the vessel radius, r. In the chambers including the non-linear term in q, however, the cross sectional area of...model the resistance factor , R, is a nonlinear function of the vessel volume (Equation 10). This is in turn a function of the elastic properties of

  2. Digital Pupillometry in Normal Subjects

    PubMed Central

    Rickmann, Annekatrin; Waizel, Maria; Kazerounian, Sara; Szurman, Peter; Wilhelm, Helmut; Boden, Karl T.

    2017-01-01

    ABSTRACT The aim of this study was to evaluate the pupil size of normal subjects at different illumination levels with a novel pupillometer. The pupil size of healthy study participants was measured with an infrared-video PupilX pupillometer (MEye Tech GmbH, Alsdorf, Germany) at five different illumination levels (0, 0.5, 4, 32, and 250 lux). Measurements were performed by the same investigator. Ninety images were executed during a measurement period of 3 seconds. The absolute linear camera resolution was approximately 20 pixels per mm. This cross-sectional study analysed 490 eyes of 245 subjects (mean age: 51.9 ± 18.3 years, range: 6–87 years). On average, pupil diameter decreased with increasing light intensities for both eyes, with a mean pupil diameter of 5.39 ± 1.04 mm at 0 lux, 5.20 ± 1.00 mm at 0.5 lux, 4.70 ± 0.97 mm at 4 lux, 3.74 ± 0.78 mm at 32 lux, and 2.84 ± 0.50 mm at 250 lux illumination. Furthermore, it was found that anisocoria increased by 0.03 mm per life decade for all illumination levels (R2 = 0.43). Anisocoria was higher under scotopic and mesopic conditions. This study provides additional information to the current knowledge concerning age- and light-related pupil size and anisocoria as a baseline for future patient studies. PMID:28228832

  3. Micro-computed Tomography versus the Cross-sectioning Method to Evaluate Dentin Defects Induced by Different Mechanized Instrumentation Techniques.

    PubMed

    Stringheta, Carolina Pessoa; Pelegrine, Rina Andréa; Kato, Augusto Shoji; Freire, Laila Gonzales; Iglecias, Elaine Faga; Gavini, Giulio; Bueno, Carlos Eduardo da Silveira

    2017-12-01

    The objective of this study was to compare the methods of micro-computed tomography (micro-CT) and cross-sectioning followed by stereomicroscopy in assessing dentinal defects after instrumentation with different mechanized systems. Forty mesial roots of mandibular molars were scanned and divided into 4 groups (n = 10): Group R, Reciproc; Group PTN, ProTaper Next; Group WOG, WaveOne Gold; Group PDL, ProDesign Logic. After instrumentation, the roots were once again submitted to a micro-CT scan, and then sectioned at 3, 6, and 9 mm from the apex, and assessed for the presence of complete and incomplete dentinal defects under a stereomicroscope. The nonparametric Kruskal-Wallis, Friedman, and Wilcoxon tests were used in the statistical analysis. The study used a significance level of 5%. The total number of defects observed by cross-sectioning followed by stereomicroscopy was significantly higher than that observed by micro-CT, in all of the experimental groups (P ≤ .05). All of the defects identified in the postoperative period were already present in the corresponding preoperative period. There was no significant difference among the instrumentation systems as to the median numbers of defects, for either cross-sectioning followed by stereomicroscopy or micro-CT, at all the root levels (P > .05). In the micro-CT analysis, no significant difference was found between the median numbers of pre- and postinstrumentation defects, regardless of the instrumentation system (P > .05). None of the evaluated instrumentation systems led to the formation of new dentin defects. All of the defects identified in the stereomicroscopic analysis were already present before instrumentation, or were absent at both time points in the micro-CT analysis, indicating that the formation of new defects resulted from the sectioning procedure performed before stereomicroscopy and not from instrumentation. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  4. Transportation and Centering Ability of Neoniti and ProTaper Instruments; A CBCT Assessment

    PubMed Central

    Madani, Zahrasadat; Soleymani, Ali; Bagheri, Tasnim; Moudi, Ehsan; Bijani, Ali; Rakhshan, Vahid

    2017-01-01

    Introduction: Transportation is an important iatrogenic endodontic error which might cause failure. This study evaluated the canal transportation caused by Neoniti and ProTaper instruments, using cone-beam computed tomography (CBCT) cross sections. Methods and Materials: This in vitro experimental study was performed on 40 mesiobuccal roots of maxillary first molars. The teeth were scanned with CBCT. They were randomly divided into 2 groups (n=20) that were prepared using either Neoniti or ProTaper files. An endodontist prepared the canal according to the manufacturer’s guidelines. Prepared canals were re-scanned. The pre-instrumentation and post-instrumentation CBCT volumes were sectioned at 1 to 9-mm distances from the apex. The extent of canal dentine removal in mesial and distal directions were measured in each cross-section. Canal transportation and instrument centering ability were estimated based on the extents of root wall removal and were compared in both groups. Results: The groups were rather similar in terms of transportation and centering ability (P>0.05). However, canal preparation on mesial and distal walls was statistically significantly less in the Neoniti group, at most cross-sections. Transportation of both groups was not significantly different (P>0.05). Centering ability of both instruments was not significantly different (P>0.05). Conclusion: Neoniti and ProTaper instruments might have proper centering ability and minimum transportations. Both instruments might cause similar extents of transportation and centering abilities. PMID:28179923

  5. A new method for synthesizing fluid inclusions in fused silica capillaries containing organic and inorganic material

    USGS Publications Warehouse

    Chou, I.-Ming; Song, Y.; Burruss, R.C.

    2008-01-01

    Considerable advances in our understanding of physicochemical properties of geological fluids and their roles in many geological processes have been achieved by the use of synthetic fluid inclusions. We have developed a new method to synthesize fluid inclusions containing organic and inorganic material in fused silica capillary tubing. We have used both round (0.3 mm OD and 0.05 or 0.1 mm ID) and square cross-section tubing (0.3 ?? 0.3 mm with 0.05 ?? 0.05 mm or 0.1 ?? 0.1 mm cavities). For microthermometric measurements in a USGS-type heating-cooling stage, sample capsules must be less than 25 mm in length. The square-sectioned capsules have the advantage of providing images without optical distortion. However, the maximum internal pressure (P; about 100 MPa at 22 ??C) and temperature (T; about 500 ??C) maintained by the square-sectioned capsules are less than those held by the round-sectioned capsules (about 300 MPa at room T, and T up to 650 ??C). The fused silica capsules can be applied to a wide range of problems of interest in fluid inclusion and hydrothermal research, such as creating standards for the calibration of thermocouples in heating-cooling stages and frequency shifts in Raman spectrometers. The fused silica capsules can also be used as containers for hydrothermal reactions, especially for organic samples, including individual hydrocarbons, crude oils, and gases, such as cracking of C18H38 between 350 and 400 ??C, isotopic exchanges between C18H38 and D2O and between C19D40 and H2O at similar temperatures. Results of these types of studies provide information on the kinetics of oil cracking and the changes of oil composition under thermal stress. When compared with synthesis of fluid inclusions formed by healing fractures in quartz or other minerals or by overgrowth of quartz at elevated P-T conditions, the new fused-silica method has the following advantages: (1) it is simple; (2) fluid inclusions without the presence of water can be formed; (3) synthesized inclusions are large and uniform, and they are able to tolerate high internal P; (4) it is suitable for the study of organic material; and (5) redox control is possible due to high permeability of the fused silica to hydrogen.

  6. Effect of ceramic membrane channel diameter on limiting retentate protein concentration during skim milk microfiltration.

    PubMed

    Adams, Michael C; Barbano, David M

    2016-01-01

    Our objective was to determine the effect of retentate flow channel diameter (4 or 6mm) of nongraded permeability 100-nm pore size ceramic membranes operated in nonuniform transmembrane pressure mode on the limiting retentate protein concentration (LRPC) while microfiltering (MF) skim milk at a temperature of 50°C, a flux of 55 kg · m(-2) · h(-1), and an average cross-flow velocity of 7 m · s(-1). At the above conditions, the retentate true protein concentration was incrementally increased from 7 to 11.5%. When temperature, flux, and average cross-flow velocity were controlled, ceramic membrane retentate flow channel diameter did not affect the LRPC. This indicates that LRPC is not a function of the Reynolds number. Computational fluid dynamics data, which indicated that both membranes had similar radial velocity profiles within their retentate flow channels, supported this finding. Membranes with 6-mm flow channels can be operated at a lower pressure decrease from membrane inlet to membrane outlet (ΔP) or at a higher cross-flow velocity, depending on which is controlled, than membranes with 4-mm flow channels. This implies that 6-mm membranes could achieve a higher LRPC than 4-mm membranes at the same ΔP due to an increase in cross-flow velocity. In theory, the higher LRPC of the 6-mm membranes could facilitate 95% serum protein removal in 2 MF stages with diafiltration between stages if no serum protein were rejected by the membrane. At the same flux, retentate protein concentration, and average cross-flow velocity, 4-mm membranes require 21% more energy to remove a given amount of permeate than 6-mm membranes, despite the lower surface area of the 6-mm membranes. Equations to predict skim milk MF retentate viscosity as a function of protein concentration and temperature are provided. Retentate viscosity, retentate recirculation pump frequency required to maintain a given cross-flow velocity at a given retentate viscosity, and retentate protein determination by mid-infrared spectrophotometry were all useful tools for monitoring the retentate protein concentration to ensure a sustainable MF process. Using 6-mm membranes instead of 4-mm membranes would be advantageous for processors who wish to reduce energy costs or maximize the protein concentration of a MF retentate. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  7. Effect of bar cross-section geometry on stress distribution in overdenture-retaining system simulating horizontal misfit and bone loss.

    PubMed

    Spazzin, Aloísio Oro; Costa, Ana Rosa; Correr, Américo Bortolazzo; Consani, Rafael Leonardo Xediek; Correr-Sobrinho, Lourenço; dos Santos, Mateus Bertolini Fernandes

    2013-08-09

    This study evaluated the influence of cross-section geometry of the bar framework on the distribution of static stresses in an overdenture-retaining bar system simulating horizontal misfit and bone loss. Three-dimensional FE models were created including two titanium implants and three cross-section geometries (circular, ovoid or Hader) of bar framework placed in the anterior part of a severely resorbed jaw. One model with 1.4-mm vertical loss of the peri-implant tissue was also created. The models set were exported to mechanical simulation software, where horizontal displacement (10, 50 or 100 μm) was applied simulating the settling of the framework, which suffered shrinkage during the laboratory procedures. The bar material used for the bar framework was a cobalt--chromium alloy. For evaluation of bone loss effect, only the 50-μm horizontal misfit was simulated. Data were qualitatively and quantitatively evaluated using von Mises stress for the mechanical part and maximum principal stress and μ-strain for peri-implant bone tissue given by the software. Stresses were concentrated along the bar and in the join between the bar and cylinder. In the peri-implant bone tissue, the μ-strain was higher in the cervical third. Higher stress levels and μ-strain were found for the models using the Hader bar. The bone loss simulated presented considerable increase on maximum principal stresses and μ-strain in the peri-implant bone tissue. In addition, for the amplification of the horizontal misfit, the higher complexity of the bar cross-section geometry and bone loss increases the levels of static stresses in the peri-implant bone tissue. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Controlled irrigation of a structured packing as a method for increasing the efficiency of liquid mixture separation in the distillation column

    NASA Astrophysics Data System (ADS)

    Pavlenko, A. N.; Zhukov, V. E.; Pecherkin, N. I.; Nazarov, A. D.; Li, X.; Li, H.; Gao, X.; Sui, H.

    2017-09-01

    The use of modern structured packing in the distillation columns allows much more even distribution of the liquid film over the packing surface, but it does not completely solve the problem of uniform distribution of flow parameters over the entire height of the packing. Negative stratification of vapor along the packing height caused by different densities of vapor mixture components and higher temperature in the lower part of the column leads to formation of large-scale maldistributions of temperature and mixture composition over the column cross-section even under the conditions of uniform irrigation of packing with liquid. In these experiments, the idea of compensatory action of liquid distributor on the large-scale maldistribution of mixture composition over the column cross-section was implemented. The experiments were carried out in the distillation column with the diameter of 0.9 m on 10 layers of the Mellapak 350Y packing with the total height of 2.1 m. The mixture of R-21 and R-114 was used as the working mixture. To irrigate the packing, the liquid distributorr with 126 independently controlled solenoid valves overlapping the holes with the diameter of 5 mm, specially designed by the authors, was used. Response of the column to the action of liquid distributor was observed in real time according to the indications of 3 groups of thermometers mounted in 3 different cross-sections of the column. The experiments showed that the minimal correction of the drip point pattern in the controlled liquid distributor can significantly affect the pattern of flow parameter distribution over the cross-section and height of the mass transfer surface and increase separation efficiency of the column within 20%.

  9. Testing the effects of topography, geometry, and kinematics on modeled thermochronometer cooling ages in the eastern Bhutan Himalaya

    NASA Astrophysics Data System (ADS)

    Gilmore, Michelle E.; McQuarrie, Nadine; Eizenhöfer, Paul R.; Ehlers, Todd A.

    2018-05-01

    In this study, reconstructions of a balanced geologic cross section in the Himalayan fold-thrust belt of eastern Bhutan are used in flexural-kinematic and thermokinematic models to understand the sensitivity of predicted cooling ages to changes in fault kinematics, geometry, topography, and radiogenic heat production. The kinematics for each scenario are created by sequentially deforming the cross section with ˜ 10 km deformation steps while applying flexural loading and erosional unloading at each step to develop a high-resolution evolution of deformation, erosion, and burial over time. By assigning ages to each increment of displacement, we create a suite of modeled scenarios that are input into a 2-D thermokinematic model to predict cooling ages. Comparison of model-predicted cooling ages to published thermochronometer data reveals that cooling ages are most sensitive to (1) the location and size of fault ramps, (2) the variable shortening rates between 68 and 6.4 mm yr-1, and (3) the timing and magnitude of out-of-sequence faulting. The predicted ages are less sensitive to (4) radiogenic heat production and (5) estimates of topographic evolution. We used the observed misfit of predicted to measured cooling ages to revise the cross section geometry and separate one large ramp previously proposed for the modern décollement into two smaller ramps. The revised geometry results in an improved fit to observed ages, particularly young AFT ages (2-6 Ma) located north of the Main Central Thrust. This study presents a successful approach for using thermochronometer data to test the viability of a proposed cross section geometry and kinematics and describes a viable approach to estimating the first-order topographic evolution of a compressional orogen.

  10. Search for nucleon decays induced by GUT magnetic monopoles with the MACRO experiment

    NASA Astrophysics Data System (ADS)

    Ambrosio, M.; Antolini, R.; Auriemma, G.; Bakari, D.; Baldini, A.; Barbarino, G. C.; Barish, B. C.; Battistoni, G.; Becherini, Y.; Bellotti, R.; Bemporad, C.; Bernardini, P.; Bilokon, H.; Bloise, C.; Bower, C.; Brigida, M.; Bussino, S.; Cafagna, F.; Calicchio, M.; Campana, D.; Carboni, M.; Caruso, R.; Cecchini, S.; Cei, F.; Chiarella, V.; Choudhary, B. C.; Coutu, S.; Cozzi, M.; de Cataldo, G.; Dekhissi, H.; de Marzo, C.; de Mitri, I.; Derkaoui, J.; de Vincenzi, M.; di Credico, A.; Erriquez, O.; Favuzzi, C.; Forti, C.; Fusco, P.; Giacomelli, G.; Giannini, G.; Giglietto, N.; Giorgini, M.; Grassi, M.; Grillo, A.; Guarino, F.; Gustavino, C.; Habig, A.; Hanson, K.; Heinz, R.; Iarocci, E.; Katsavounidis, E.; Katsavounidis, I.; Kearns, E.; Kim, H.; Kyriazopoulou, S.; Lamanna, E.; Lane, C.; Levin, D. S.; Lipari, P.; Longley, N. P.; Longo, M. J.; Loparco, F.; Maaroufi, F.; Mancarella, G.; Mandrioli, G.; Manzoor, S.; Margiotta, A.; Marini, A.; Martello, D.; Marzari-Chiesa, A.; Mazziotta, M. N.; Michael, D. G.; Monacelli, P.; Montaruli, T.; Monteno, M.; Mufson, S.; Musser, J.; Nicolò, D.; Nolty, R.; Orth, C.; Osteria, G.; Palamara, O.; Patera, V.; Patrizii, L.; Pazzi, R.; Peck, C. W.; Perrone, L.; Petrera, S.; Pistilli, P.; Popa, V.; Rainò, A.; Reynoldson, J.; Ronga, F.; Rrhioua, A.; Satriano, C.; Scapparone, E.; Scholberg, K.; Sciubba, A.; Serra, P.; Sioli, M.; Sirri, G.; Sitta, M.; Spinelli, P.; Spinetti, M.; Spurio, M.; Steinberg, R.; Stone, J. L.; Sulak, L. R.; Surdo, A.; Tarlè, G.; Togo, V.; Vakili, M.; Walter, C. W.; Webb, R.

    2002-12-01

    The interaction of a Grand Unification Magnetic Monopole with a nucleon can lead to a barion-number violating process in which the nucleon decays into a lepton and one or more mesons (catalysis of nucleon decay). In this paper we report an experimental study of the effects of a catalysis process in the MACRO detector. Using a dedicated analysis we obtain new magnetic monopole (MM) flux upper limits at the level of \\char1263\\cdot 10^{-16} cm^{-2} s^{-1} sr^{-1} for 1.1\\cdot 10^{-4} le \\vertβ\\vert le 5\\cdot 10^{-3}, based on the search for catalysis events in the MACRO data. We also analyze the dependence of the MM flux limit on the catalysis cross section.

  11. Effect of hole geometry and Electric-Discharge Machining (EDM) on airflow rates through small diameter holes in turbine blade material

    NASA Technical Reports Server (NTRS)

    Hippensteele, S. A.; Cochran, R. P.

    1980-01-01

    The effects of two design parameters, electrode diameter and hole angle, and two machine parameters, electrode current and current-on time, on air flow rates through small-diameter (0.257 to 0.462 mm) electric-discharge-machined holes were measured. The holes were machined individually in rows of 14 each through 1.6 mm thick IN-100 strips. The data showed linear increase in air flow rate with increases in electrode cross sectional area and current-on time and little change with changes in hole angle and electrode current. The average flow-rate deviation (from the mean flow rate for a given row) decreased linearly with electrode diameter and increased with hole angle. Burn time and finished hole diameter were also measured.

  12. Terahertz Imaging of Three-Dimensional Dehydrated Breast Cancer Tumors

    NASA Astrophysics Data System (ADS)

    Bowman, Tyler; Wu, Yuhao; Gauch, John; Campbell, Lucas K.; El-Shenawee, Magda

    2017-06-01

    This work presents the application of terahertz imaging to three-dimensional formalin-fixed, paraffin-embedded human breast cancer tumors. The results demonstrate the capability of terahertz for in-depth scanning to produce cross section images without the need to slice the tumor. Samples of tumors excised from women diagnosed with infiltrating ductal carcinoma and lobular carcinoma are investigated using a pulsed terahertz time domain imaging system. A time of flight estimation is used to obtain vertical and horizontal cross section images of tumor tissues embedded in paraffin block. Strong agreement is shown comparing the terahertz images obtained by electronically scanning the tumor in-depth in comparison with histopathology images. The detection of cancer tissue inside the block is found to be accurate to depths over 1 mm. Image processing techniques are applied to provide improved contrast and automation of the obtained terahertz images. In particular, unsharp masking and edge detection methods are found to be most effective for three-dimensional block imaging.

  13. Passive Q-switching of a Tm:YLF laser with a Co2+ doped silver halide saturable absorber

    NASA Astrophysics Data System (ADS)

    Hecht, Harel; Burshtein, Zeev; Katzir, Abraham; Noach, Salman; Sokol, Maxim; Frumker, Eugene; Galun, Ehud; Ishaaya, Amiel A.

    2017-02-01

    We report a successful passive Q-switching of a Tm:YLF laser operating at λ = 1.9 μm, using a Co2+:AgCl0.5Br0.5 saturable absorber. Approximately 200-ns long, 150 μJ pulses were obtained. Increase in pump energy resulted in repetitive pulsing, with a repetition rate approximately proportional to the pump pulse energy. Room-temperature optical transmission saturation curves measured in ∼1-mm thick Co2+:AgCl0.5Br0.5 plates yielded a ground state absorption cross section σgs =(7.8 ± 0.5) ×10-18 cm2 , and an excited state absorption cross section σes =(3.3 ± 0.3) ×10-18 cm2 , at λ = 1.9 μm. The lifetime of the A2(4F) second excited-state of the octahedral O symmetry was τ∗ =(0.6 ± 0.06) ns .

  14. Cross-sectional examination of the damage zone in impacted specimens of carbon/epoxy and carbon/PEEK composites

    NASA Technical Reports Server (NTRS)

    Nettles, A. T.; Magold, N. J.

    1990-01-01

    Drop weight impact testing was utilized to inflict damage on eight-ply bidirectional and unidirectional samples of carbon/epoxy and carbon/PEEK (polyetheretherketone) test specimens with impact energies ranging from 0.80 J to 1.76 J. The impacting tip was of a smaller diameter (4.2-mm) than those used in most previous studies, and the specimens were placed with a diamond wheel wafering saw through the impacted area perpendicular to the outer fibers. Photographs at 12 x magnification were taken of these cross-sections and examined. The results on the bidirectional samples show little damage until 1.13 J, at which point delaminations were seen in the epoxy specimens. The PEEK specimens showed less delamination than the epoxy specimens for a given impact energy level. The unidirectional specimens displayed more damage than the bidirectional samples for a given impact energy, with the PEEK specimens showing much less damage than the epoxy material.

  15. Anatomy-driven design of a prototype video laryngoscope for extremely low birth weight infants

    NASA Astrophysics Data System (ADS)

    Baker, Katherine; Tremblay, Eric; Karp, Jason; Ford, Joseph; Finer, Neil; Rich, Wade

    2010-11-01

    Extremely low birth weight (ELBW) infants frequently require endotracheal intubation for assisted ventilation or as a route for administration of drugs or exogenous surfactant. In adults and less premature infants, the risks of this intubation can be greatly reduced using video laryngoscopy, but current products are too large and incorrectly shaped to visualize an ELBW infant's airway anatomy. We design and prototype a video laryngoscope using a miniature camera set in a curved acrylic blade with a 3×6-mm cross section at the tip. The blade provides a mechanical structure for stabilizing the tongue and acts as a light guide for an LED light source, located remotely to avoid excessive local heating at the tip. The prototype is tested on an infant manikin and found to provide sufficient image quality and mechanical properties to facilitate intubation. Finally, we show a design for a neonate laryngoscope incorporating a wafer-level microcamera that further reduces the tip cross section and offers the potential for low cost manufacture.

  16. Definition of a safe zone for antegrade lag screw fixation of fracture of posterior column of the acetabulum by 3D technology.

    PubMed

    Feng, Xiaoreng; Zhang, Sheng; Luo, Qiang; Fang, Jintao; Lin, Chaowen; Leung, Frankie; Chen, Bin

    2016-03-01

    The objective of this study was to define a safe zone for antegrade lag screw fixation of fracture of posterior column of the acetabulum using a novel 3D technology. Pelvic CT data of 59 human subjects were obtained to reconstruct three-dimensional (3D) models. The transparency of 3D models was then downgraded along the axial perspective (the view perpendicular to the cross section of the posterior column axis) to find the largest translucent area. The outline of the largest translucent area was drawn on the iliac fossa. The line segments of OA, AB, OC, CD, the angles of OAB and OCD that delineate the safe zone (ABDC) were precisely measured. The resultant line segments OA, AB, OC, CD, and angles OAB and OCD were 28.46mm(13.15-44.97mm), 45.89mm (34.21-62.85mm), 36.34mm (18.68-55.56mm), 53.08mm (38.72-75.79mm), 37.44° (24.32-54.96°) and 55.78° (43.97-79.35°) respectively. This study demonstrates that computer-assisted 3D modelling techniques can aid in the precise definition of the safe zone for antegrade insertion of posterior column lag screws. A full-length lag screw can be inserted into the zone (ABDC), permitting a larger operational error. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Low concentrations of folate, not hyperhomocysteinemia, are associated with carotid intima-media thickness.

    PubMed

    Durga, Jane; Bots, Michiel L; Schouten, Evert G; Kok, Frans J; Verhoef, Petra

    2005-04-01

    We examined whether total homocysteine, B vitamins and the 5,10-methylenetetrahydrofolate reductase (MTHFR) 677C-->T polymorphism are related to common carotid intima-media thickness, a marker of atherosclerosis, and carotid distension, a marker of arterial stiffness. We used cross-sectional data from 819 individuals aged 50-70 years. B-mode ultrasound of the distal common carotid arteries was performed to determine maximum carotid intima-media thickness, mean carotid intima-media thickness and distension. Carotid intima-media thickness and distension did not differ across homocysteine, serum folate, vitamin B(6) and vitamin B(12) quartiles or between MTHFR C677T genotype. Erythrocyte folate was independently associated with maximum carotid intima-media thickness (mean difference first versus third quartile, 0.03 mm, 95% CI 0.004-0.06 mm; first versus fourth quartile, 0.03 mm, 95% CI -0.002 to 0.06 mm). Further adjustment for homocysteine did not affect this association. Folate deficient subjects had greater maximum carotid intima-media thickness than those with high-normal folate concentrations (serum folate: mean difference 0.05 mm, 95% CI 0.01-0.08 mm; erythrocyte folate: mean difference 0.04 mm, 95% CI -0.03 to 0.11 mm). Low folate concentrations, independent of hyperhomocysteinemia, may promote atherogenesis. Our findings confirm the null association of homocysteine with carotid intima-media thickness observed in other population-based studies, suggesting that hyperhomocysteinemia does not perpetuate atherosclerosis or arterial stiffness.

  18. A micromechanical expanding coil mechanism for in vivo magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Ichiki, M.; Syms, R. R. A.; Young, I. R.

    2005-04-01

    A mechanism for an expanding coil designed for use for in vivo magnetic resonance imaging is demonstrated. The mechanism has a small (1 mm) cross-sectional width, and may therefore be passed through a tubular orifice such as the endoscope channel used for accessing a bile duct. Once in place, the coil may be deformed by controlled in-plane buckling and fixed in this state by a rack-and-tooth latch. The latch may be released to return the mechanism to its original state for withdrawal. A simple analytic model of the device is developed using Euler bending theory. Prototypes are fabricated in bonded silicon-on-insulator material by deep reactive ion etching and undercut. Expansion and latching are demonstrated, and performance characteristics are found to be in good agreement with the theoretical models. A lateral expansion of 1 mm was routinely achieved on either side of a device with an initial width of 1 mm (corresponding to a three-fold expansion) using an axial compression of 400 µm.

  19. Neutron induced fission cross section measurements of 240Pu and 242Pu

    NASA Astrophysics Data System (ADS)

    Belloni, F.; Eykens, R.; Heyse, J.; Matei, C.; Moens, A.; Nolte, R.; Plompen, A. J. M.; Richter, S.; Sibbens, G.; Vanleeuw, D.; Wynants, R.

    2017-09-01

    Accurate neutron induced fission cross section of 240Pu and 242Pu are required in view of making nuclear technology safer and more efficient to meet the upcoming needs for the future generation of nuclear power plants (GEN-IV). The probability for a neutron to induce such reactions figures in the NEA Nuclear Data High Priority Request List [1]. A measurement campaign to determine neutron induced fission cross sections of 240Pu and 242Pu at 2.51 MeV and 14.83 MeV has been carried out at the 3.7 MV Van De Graaff linear accelerator at Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig. Two identical Frisch Grid fission chambers, housing back to back a 238U and a APu target (A = 240 or A = 242), were employed to detect the total fission yield. The targets were molecular plated on 0.25 mm aluminium foils kept at ground potential and the employed gas was P10. The neutron fluence was measured with the proton recoil telescope (T1), which is the German primary standard for neutron fluence measurements. The two measurements were related using a De Pangher long counter and the charge as monitors. The experimental results have an average uncertainty of 3-4% at 2.51 MeV and for 6-8% at 14.81 MeV and have been compared to the data available in literature.

  20. Protozoa and metazoa relations to technological conditions of non-woven textile filters for wastewater treatment.

    PubMed

    Spychała, Marcin; Sowińska, Aleksandra; Starzyk, Justyna; Masłowski, Adam

    2015-01-01

    The objective of this study was a preliminary identification of basic groups of micro-organisms in the cross-sectional profile of geotextile filters for septic tank effluent (STE) treatment and their relations to technological conditions. Reactors with textile filters treating wastewater were investigated on a semi-technical scale. Filters were vertically situated and STE was filtered through them under hydrostatic pressure at a wastewater surface height of 7-20 cm. Filters were made of four layers of non-woven TS 20 geotextile of 0.9 mm thickness. Various groups of organisms were observed; the most abundant group comprised free-swimming and crawling ciliates, less abundant were stalked ciliates and the least numerous were nematodes. The individual counts of all groups of micro-organisms investigated during the study were variable according to time and space. The high abundance of Opercularia, a commonly observed genus of stalked ciliates, was related to the high efficiency of wastewater treatment and dissolved oxygen concentration of about 1.0 g/m3. Numbers of free-swimming and crawling ciliates had a tendency to decrease in relation to the depth of filter cross-sectional profile. The variability in counts of particular groups of organisms could be related to the local stress conditions. No correlation between identified organism count and total mass concentration in the cross-sectional filter profile was found.

  1. Macroscopic strain controlled ion current in an elastomeric microchannel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuo, Chin-Chang; Nguyen, Du; Buchsbaum, Steven

    We report on the fabrication of an ultra-high aspect ratio ionically conductive single microchannel with tunable diameter from ≈ 20 μm to fully closed. The 4 mm-long channel is fabricated in a Polydimethylsiloxane (PDMS) mold and its cross-sectional area is controlled by applying macroscopic compressive strain to the mold in a direction perpendicular to the channel length. We investigated the ionic conduction properties of the channel. For a wide range of compressive strain up to ≈ 0.27, the strain dependence of the resistance is monotonic and fully reversible. For strain > 0.27, ionic conduction suddenly shuts off and the system becomes hystereticmore » (whereby a finite strain reduction is required to reopen the channel). Upon unloading, the original behavior is retrieved. This reversible behavior is observed over 200 compression cycles. The cross-sectional area of the channel can be inferred from the ion current measurement, as confirmed by a Nano-Computed Tomography investigation. We show that the cross-sectional area decreases monotonically with the applied compressive strain in the reversible range, in qualitative agreement with linear elasticity theory. We find that the shut-off strain is affected by the spatial extent of the applied strain, which provides additional tunability. Our tunable channel is well-suited for multiple applications in micro/nano-fluidic devices.« less

  2. Patient size and x-ray technique factors in head computed tomography examinations. I. Radiation doses.

    PubMed

    Huda, Walter; Lieberman, Kristin A; Chang, Jack; Roskopf, Marsha L

    2004-03-01

    We investigated how patient age, size and composition, together with the choice of x-ray technique factors, affect radiation doses in head computed tomography (CT) examinations. Head size dimensions, cross-sectional areas, and mean Hounsfield unit (HU) values were obtained from head CT images of 127 patients. For radiation dosimetry purposes patients were modeled as uniform cylinders of water. Dose computations were performed for 18 x 7 mm sections, scanned at a constant 340 mAs, for x-ray tube voltages ranging from 80 to 140 kV. Values of mean section dose, energy imparted, and effective dose were computed for patients ranging from the newborn to adults. There was a rapid growth of head size over the first two years, followed by a more modest increase of head size until the age of 18 or so. Newborns have a mean HU value of about 50 that monotonically increases with age over the first two decades of life. Average adult A-P and lateral dimensions were 186+/-8 mm and 147+/-8 mm, respectively, with an average HU value of 209+/-40. An infant head was found to be equivalent to a water cylinder with a radius of approximately 60 mm, whereas an adult head had an equivalent radius 50% greater. Adult males head dimensions are about 5% larger than for females, and their average x-ray attenuation is approximately 20 HU greater. For adult examinations performed at 120 kV, typical values were 32 mGy for the mean section dose, 105 mJ for the total energy imparted, and 0.64 mSv for the effective dose. Increasing the x-ray tube voltage from 80 to 140 kV increases patient doses by about a factor of 5. For the same technique factors, mean section doses in infants are 35% higher than in adults. Energy imparted for adults is 50% higher than for infants, but infant effective doses are four times higher than for adults. CT doses need to take into account patient age, head size, and composition as well as the selected x-ray technique factors.

  3. Imaging spinal cord atrophy in progressive myelopathies: HTLV-I-associated neurological disease (HAM/TSP) and multiple sclerosis (MS).

    PubMed

    Azodi, Shila; Nair, Govind; Enose-Akahata, Yoshimi; Charlip, Emily; Vellucci, Ashley; Cortese, Irene; Dwyer, Jenifer; Billioux, B Jeanne; Thomas, Chevaz; Ohayon, Joan; Reich, Daniel S; Jacobson, Steven

    2017-11-01

    Previous work measures spinal cord thinning in chronic progressive myelopathies, including human T-lymphotropic virus 1 (HTLV-1)-associated myelopathy/tropical spastic paraparesis (HAM/TSP) and multiple sclerosis (MS). Quantitative measurements of spinal cord atrophy are important in fully characterizing these and other spinal cord diseases. We aimed to investigate patterns of spinal cord atrophy and correlations with clinical markers. Spinal cord cross-sectional area was measured in individuals (24 healthy controls [HCs], 17 asymptomatic carriers of HTLV-1 (AC), 47 HAM/TSP, 74 relapsing-remitting MS [RRMS], 17 secondary progressive MS [SPMS], and 40 primary progressive MS [PPMS]) from C1 to T10. Clinical disability scores, viral markers, and immunological parameters were obtained for patients and correlated with representative spinal cord cross-sectional area regions at the C2 to C3, C4 to C5, and T4 to T9 levels. In 2 HAM/TSP patients, spinal cord cross-sectional area was measured over 3 years. All spinal cord regions are thinner in HAM/TSP (56 mm 2 [standard deviation, 10], 59 [10], 23 [5]) than in HC (76 [7], 83 [8], 38 [4]) and AC (71 [7], 78 [9], 36 [7]). SPMS (62 [9], 66 [9], 32 [6]) and PPMS (65 [11], 68 [10], 35 [7]) have thinner cervical cords than HC and RRMS (73 [9], 77 [10], 37 [6]). Clinical disability scores (Expanded Disability Status Scale [p = 0.009] and Instituto de Pesquisas de Cananeia [p = 0.03]) and CD8 + T-cell frequency (p = 0.04) correlate with T4 to T9 spinal cord cross-sectional area in HAM/TSP. Higher cerebrospinal fluid HTLV-1 proviral load (p = 0.01) was associated with thinner spinal cord cross-sectional area. Both HAM/TSP patients followed longitudinally showed thoracic thinning followed by cervical thinning. Group average spinal cord cross-sectional area in HAM/TSP and progressive MS show spinal cord atrophy. We further hypothesize in HAM/TSP that is possible that neuroglial loss from a thoracic inflammatory process results in anterograde and retrograde degeneration of axons, leading to the temporal progression of thoracic to cervical atrophy described here. Ann Neurol 2017;82:719-728. © 2017 American Neurological Association.

  4. Innovative design of closing loops producing an optimal force system applicable in the 0.022-in bracket slot system.

    PubMed

    Sumi, Mayumi; Koga, Yoshiyuki; Tominaga, Jun-Ya; Hamanaka, Ryo; Ozaki, Hiroya; Chiang, Pao-Chang; Yoshida, Noriaki

    2016-12-01

    Most closing loops designed for producing higher moment-to-force (M/F) ratios require complex wire bending and are likely to cause hygiene problems and discomfort because of their complicated configurations. We aimed to develop a simple loop design that can produce optimal force and M/F ratio. A loop design that can generate a high M/F ratio and the ideal force level was investigated by varying the portion and length of the cross-sectional reduction of a teardrop loop and the loop position. The forces and moments acting on closing loops were calculated using structural analysis based on the tangent stiffness method. An M/F ratio of 9.3 (high enough to achieve controlled movement of the anterior teeth) and an optimal force level of approximately 250 g of force can be generated by activation of a 10-mm-high teardrop loop whose cross-section of 0.019 × 0.025 or 0.021 × 0.025 in was reduced in thickness by 50% for a distance of 3 mm from the apex, located between a quarter and a third of the interbracket distance from the canine bracket. The simple loop design that we developed delivers an optimal force and an M/F ratio for the retraction of anterior teeth, and is applicable in a 0.022-in slot system. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  5. Effect of Pesticide Exposure on Immunological, Hematological and Biochemical Parameters in Thai Orchid Farmers—A Cross-Sectional Study

    PubMed Central

    Aroonvilairat, Soraya; Kespichayawattana, Wannapa; Sornprachum, Thiwaree; Chaisuriya, Papada; Siwadune, Taweeratana; Ratanabanangkoon, Kavi

    2015-01-01

    Various studies have found that many Thai orchid farmers used excessive amounts of pesticides without proper protective gear, but no toxicological study has been made. This cross-sectional study aimed to evaluate the immunological, hematological and biochemical statuses of these farmers. Sixty four orchid farmers and 60 controls were studied. Plasma cholinesterase activity, the percentage and absolute number of B lymphocytes (CD19+) were significantly lower in the farmers group (3966.32 ± 1165.48 U/L, 11.61 ± 4.09% and 312.26 ± 164.83 cells/mm3, respectively) as compared to those of controls (5048.85 ± 1139.40 U/L, 14.32 ± 4.23%, 420.34 ± 195.18 cells/mm3, respectively). There was a statistically significant higher level of serum IgE among the orchid farmers (0.031 ± 0.011 mg/dL vs. 0.018 ± 0.007 mg/dL) but not IgG, IgA and IgM, levels. Serum lysozyme level, lymphocyte proliferative responses to mitogens, hematological parameters and kidney function test, were not significantly different between the two groups. The liver function profiles showed significantly lower levels of albumin and serum protein in the farmer group. Thus frequent pesticide exposure resulted in subtle changes of some biological parameters. These changes, though may not be clinically significant, strongly indicated that caution in handing pesticides by these farmers is warranted. PMID:26024358

  6. Shear thinning effects on blood flow in straight and curved tubes

    NASA Astrophysics Data System (ADS)

    Cherry, Erica M.; Eaton, John K.

    2013-07-01

    Simulations were performed to determine the magnitude and types of errors one can expect when approximating blood in large arteries as a Newtonian fluid, particularly in the presence of secondary flows. This was accomplished by running steady simulations of blood flow in straight and curved tubes using both Newtonian and shear-thinning viscosity models. In the shear-thinning simulations, the viscosity was modeled as a shear rate-dependent function fit to experimental data. Simulations in straight tubes were modeled after physiologically relevant arterial flows, and flow parameters for the curved tube simulations were chosen to examine a variety of secondary flow strengths. The diameters ranged from 1 mm to 10 mm and the Reynolds numbers from 24 to 1500. Pressure and velocity data are reported for all simulations. In the straight tube simulations, the shear-thinning flows had flattened velocity profiles and higher pressure gradients compared to the Newtonian simulations. In the curved tube flows, the shear-thinning simulations tended to have blunted axial velocity profiles, decreased secondary flow strengths, and decreased axial vorticity compared to the Newtonian simulations. The cross-sectionally averaged pressure drops in the curved tubes were higher in the shear-thinning flows at low Reynolds number but lower at high Reynolds number. The maximum deviation in secondary flow magnitude averaged over the cross sectional area was 19% of the maximum secondary flow and the maximum deviation in axial vorticity was 25% of the maximum vorticity.

  7. A study of resonant-cavity and fiberglass-filled parallel baffles as duct silencers. [for wind tunnels

    NASA Technical Reports Server (NTRS)

    Soderman, P. T.

    1982-01-01

    Acoustical performance and pressure drop were measured for two types of splitters designed to attenuate sound propagating in ducts - resonant-cavity baffles and fiberglass-filled baffles. Arrays of four baffles were evaluated in the 7- by 10-foot wind tunnel number 1 at Ames Research Center at flow speeds from 0 to 41 m/sec. The baffles were 2.1 m high, 305 to 406 mm thick, and 3.1 to 4.4 m long. Emphasis was on measurements of silencer insertion loss as affected by variations of such parameters as baffle length, baffle thickness, perforated skin geometry, cavity size and shape, cavity damping, wind speed, and acoustic field directivity. An analytical method for predicting silencer performance is described and compared with measurements. With the addition of cavity damping in the form of 25-mm foam linings, the insertion loss above 250 Hz of the resonant-cavity baffles was improved 2 to 7 db compared with the undamped baffles; the loss became equal to or greater than the insertion loss of comparable size fiberglass baffles at frequencies above 250 Hz. Variations of cavity size and shape showed that a series of cavities with triangular cross-sections (i.e., variable depth) were superior to cavities with rectangular cross sections (i.e., constant depth). In wind, the undamped, resonant-cavity baffles generated loud cavity-resonance tones; the tones could be eliminated by cavity damping.

  8. Interior tomographic imaging for x-ray coherent scattering (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Pang, Sean; Zhu, Zheyuan

    2017-05-01

    Conventional computed tomography reconstructs the attenuation only high-dimensional images. Coherent scatter computed tomography, which reconstructs the angular dependent scattering profiles of 3D objects, can provide molecular signatures that improves the accuracy of material identification and classification. Coherent scatter tomography are traditionally acquired by setups similar to x-ray powder diffraction machine; a collimated source in combination with 2D or 1D detector collimation in order to localize the scattering point. In addition, the coherent scatter cross-section is often 3 orders of magnitude lower than that of the absorption cross-section for the same material. Coded aperture and structured illumination approaches has been shown to greatly improve the collection efficiency. In many applications, especially in security imaging and medical diagnosis, fast and accurate identification of the material composition of a small volume within the whole object would lead to an accelerated imaging procedure and reduced radiation dose. Here, we report an imaging method to reconstruct the material coherent scatter profile within a small volume. The reconstruction along one radial direction can reconstruct a scalar coherent scattering tomographic image. Our methods takes advantage of the finite support of the scattering profile in small angle regime. Our system uses a pencil beam setup without using any detector side collimation. Coherent scatter profile of a 10 mm scattering sample embedded in a 30 mm diameter phantom was reconstructed. The setup has small form factor and is suitable for various portable non-destructive detection applications.

  9. Diode-pumped Yb:Sr{sub 5}(PO{sub 4}){sub 3}F laser performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, C.D.; Payne, S.A.; Smith, L.K.

    The performance of the first diode-pumped Yb{sup 3+}-doped Sr{sub 5}(PO{sub 4}){sub 3}F (Yb:S-FAP) laser is discussed. We found the pumping dynamics and extraction cross-sections of Yb:S-FAP crystals to be similar to those previously inferred by purely spectroscopic techniques. The saturation fluence for pumping was measured to be 2.2 J/cm{sup 2} using three different methods based on either the spatial, temporal, or energy transmission properties of a Yb:S-FAP rod. The small signal gain implies an emission cross section of 6.0 x 10{sup -20} cm{sup 2} that falls within error bars of the previously reported value of 7.3 x 10{sup -20} cm{supmore » 2}, obtained from spectroscopic techniques. Up to 1.7 J/cm{sup 3} of stored energy density was achieved in a 6 x 6 x 44 mm Yb:S-FAP amplifier rod. An InGaAs diode array has been fabricated that has suitable specifications for pumping a 3 x 3 x 30 mm Yb:S-FAP rod. In a free running configuration diode-pumped slope efficiencies up to 43% were observed with output energies up to {approximately}0.5 J per 1 ms pulse. When the rod was mounted in a copper block for cooling, 13 W of average power was produced with power supply limited operation at 70 Hz and 500 {mu}s pulses.« less

  10. Aseismic slip and surface creep on the Hazar-Palu Section of the East Anatolian Fault, Turkey

    NASA Astrophysics Data System (ADS)

    Ergintav, S.; Cakir, Z.; Dogan, U.; Cetin, S.; Senturk, S.; Karabulut, H.; Saroglu, F.; Dikmen, U.; Bilham, R. G.; Ozdemir, A.; Julaiti, W.; Ozener, H.

    2017-12-01

    Forming the boundary between the Anatolian and Arabian plates in Turkey, the East Anatolian fault (EAF) is one of the most important tectonic structures in the Eastern Mediterranean region. Together with its conjugate, the North Anatolian Fault (NAF), it accommodates the westward motion of the Anatolian plate at a rate of 10 mm/yr. We study the interseismic deformation along the eastern section of the EAF using SAR data (2012-2017). Interferograms are calculated, using GMT5SAR software (Sandwell et al., 2011). The interferograms are then used to map the velocity field with the Stanford Method for Persistent Scatterers technique (STAMPS; Hooper et al., 2012). In 2015 a new GPS network was established with 6 fault perpendicular profiles crossing segments identified to be creeping from SAR analysis. The closest GPS sites are within 2 km from the surface EAF. Far-field continuous GPS sites permit us to determine the long-term slip rate and hence the depth of creep on the fault using dislocation models. Additionally, two creepmeters were installed to monitor fault creep in a railway tunnel crossing the fault at ≈50 m depth below the ruined medieval village of Palu, at a location where the walls of the tunnel have been offset by 10-20 cm since construction in the middle of the last century. To confirm these results, earthquake catalogs were, also, re-analyzed. The preliminary results, which are obtained from multidisciplinary data, confirm the average slip rate of the EAF is about 10 mm/yr. The results also reveal that the 100-km-long Palu segment in the Elazıg-Bingöl seismic gap is exhibiting aseismic creep at the surface. The surface creep rate varies along the fault locally attaining the far field plate velocity (i.e. 10 mm/yr), implying that significant portion of the elastic strain has been released aseismically. Preliminary modelling with elastic dislocations suggests that some sections of the fault may be creeping from the surface down to the entire seismogenic crust. Our data are the first to confirm aseismic slip on the EAF (supported by TUBITAK 1001 project no:114Y250)

  11. TU-H-CAMPUS-TeP2-03: High Sensitivity and High Resolution Fiber Based Micro-Detector for Sub-Millimeter Preclinical Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Izaguirre, E; Pokhrel, S; Knewtson, T

    2016-06-15

    Purpose: Current precision of small animal and cell micro-irradiators has continuously increased during the past years. Currently, preclinical irradiators can deliver sub-millimeter fields with micrometric precision but there are no water equivalent dosimeters to determine small field profiles and dose in the orthovoltage range of energies with micrometric resolution and precision. We have developed a fiber based micro-dosimeter with the resolution and dosimetric accuracy required for radiobiological research. Methods: We constructed two prototypes of micro-dosimeters based on different compositions of fiber scintillators to study the spatial resolution and dosimetric precision of small animal and cell micro-irradiators. The first has greenmore » output and the second has blue output. The blue output dosimeter has the highest sensitivity because it matches the spectral sensitivity of silicon photomultipliers. A blue detector with 500um cross section was built and tested respect to a CC01 ion chamber, film, and the 1500um green output detector. Orthovoltage fields from 1×1mm2 to 5×5mm2 were used for detector characteristics comparison. Results: The blue fiber dosimeter shows great agreement with films and matches dose measurements with the gold-standard ion chamber for 5×5mm2 fields. The detector has the appropriate sensitivity to measure fields from 1×1mm2 to larger sizes with a 1% dosimetric accuracy. The spatial resolution is in the sub-millimeter range and the spectral matching with the photomultiplier allows reducing the sensor cross section even further than the presented prototype. These results suggest that scintillating fibers combined with silicon photomultipliers is the appropriate technology to pursue micro-dosimetry for small animals and disperse cell samples. Conclusion: The constructed detectors establish a new landmark for the resolution and sensitivity of fiber based microdetectors. The validation of the detector in our small animal and cell irradiator shows that they are appropriate for preclinical and micro single cell irradiation quality assurance and dosimetry.« less

  12. Using anatomical landmark to avoid phrenic nerve injury during balloon-based procedures in atrial fibrillation patients.

    PubMed

    Smith, Nicolina M; Segars, Larry; Kauffman, Travis; Olinger, Anthony B

    2017-12-01

    Atrial fibrillation (AF) is an arrhythmia which affects as many as 2.7 million Americans. AF should be treated, because it can lead to a four-to-fivefold increased risk of experiencing a stroke. The American College of Cardiology/American Heart Association guidelines for the treatment of drug refractory and symptomatic paroxysmal AF denote catheter ablation as the standard of care. The newest ablation treatment, cryoballoon, uses a cold balloon tip. The biggest risk factor associated with the cryoballoon ablation is phrenic nerve injury (PNI). The purpose of this study is to measure relevant distances from specific landmarks to the right phrenic nerve (RPN) to create a safe zone for physicians. Using 30 cadaveric specimens, we measured laterally from the right superior pulmonary vein orifice (RSPV) to the RPN at the level of the sixth thoracic vertebra and laterally from the lateral border of the sixth thoracic vertebral body (T6) to the RPN. The depth and width of the left atrium (LA) were also measured to establish a cross-sectional area of the LA. The cross-sectional area of the LA was then correlated with the averaged measurements to see if the area of the LA could be a predictor of the location of the RPN. The average distance from the RPN-RSPV was 9.6 mm (range 4.3-18.8 mm). The average RPN-T6 distance was 30.6 mm (range 13.7-49.9 mm). There was a non-significant trend that suggests as the size of the LA increases, the measured distances also increased. Using the lateral border of the sixth thoracic vertebra as a landmark, which can be viewed under fluoroscopy during the procedure, physicians can triangulate the distance to the RSPV and determine the approximate position of the RPN. Furthermore, physicians can perform a preoperative echocardiogram to determine the size of the LA to assist in determining the position of the RPN with the hopes of avoiding injury to the RPN.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, H; Dolly, S; Anastasio, M

    Purpose: Head and neck (H&N) internal organ motion has previously been determined with low frequency and temporary nature based on population-based pre- and post-treatment studies. Using immobilization masks and adding a 4–6 mm planning-tumor-volume margin, geometric uncertainties of patients are routinely considered clinically inconsequential in H&N radiotherapy. Using the first commercially-available MR-IGRT system, we conducted the first quantitative study on inter-patient, intra- and inter-fractional H&N internal motion patterns to evaluate the necessity of individualized asymmetric internal margins. Methods: Ninety cine sagittal MR image sequences were acquired during the entire treatment course (6–7 weeks) of three H&N cancer patients using themore » ViewRay™ MR-IGRT system. The images were 5 mm thick and acquired at 4 frames/per second. One of the patients had a tracheostomy tube. The cross-sectional H&N airway (nasopharynx, oropharynx, and laryngopharynx portions) movement was analyzed comprehensively using in-house developed motion detection software. Results: Large inter-patient variations of swallowing frequency (0–1 times/per fraction), swallowing duration (1–3 seconds), and pharyngeal cross-sectional area (238–2516 mm2) were observed. Extensive pharyngeal motion occurred during swallowing, while nonzero and periodic change of airway geometry was observed in resting. For patient 1 with tracheostomy tube replacement, 30.3%, 30.0%, 48.7% and 0.3% of total frames showed ≥ 4 mm displacements in the anterior, posterior, inferior, and superior airway boundaries, respectively; similarly, (5.7%, 0.0%, 0.0%, 0.3%) and (23.3%, 0.0%, 35.7%, 1.7%) occurred for patients 2 and 3. Area overlapping coefficients with respect to the first frame were 76.3+/−6.4%, 90.3+/−0.6%, and 92.3+/−1.2% for the three patients, respectively. Conclusion: Both the resting and swallowing motions varied in frequency and amplitude among the patients and across fractions of a patient’s treatment. Patients receiving surgery that alters their respiratory and swallowing behavior can have significant intra-fractional internal motion. Patient-specific organ/tumor motion analysis may yield individualized asymmetric internal margins and improve the therapeutic ratio.« less

  14. Trends in baseline CD4 cell counts and risk factors for late antiretroviral therapy initiation among HIV-positive patients in Shanghai, a retrospective cross-sectional study.

    PubMed

    Sun, Jianjun; Liu, Li; Shen, Jiayin; Chen, Panpan; Lu, Hongzhou

    2017-04-19

    There are few studies focus on the factors underlying the late initiation of ART in China. We analyzed the trends in the median CD4 cell counts among different patient groups over time and the risk factors for the late initiation of ART in Shanghai, China. A retrospective cross-sectional survey was made in the Department of Infectious Disease of Shanghai Public Health Clinical Center which is a designated diagnosis and treatment center for HIV-positive patients in Shanghai during the period of January 1st, 2008--June 30th, 2014. Late ART initiation was defined as a CD4 cell count <200 cells/mm 3 or having a clinical AIDS diagnosis prior to ART initiation. Trends in the median CD4 cell count at ART initiation and the proportion of late ART initiation by year were evaluated using Spearman's correlations and Chi-squared methods, respectively. We used a logistic regression model to analyze the risk factors for late ART initiation. The related factors collected in the multivariate model were the patient's age, gender, infection routes and marital status. A total of 3796 patients were analyzed in this study, with a median baseline CD4 cell count of 205 cells/mm 3 [interquartile range: 75-287]. The median CD4 cell counts of patients initiating ART late increased from 76 cells/mm 3 in 2008 to 103 cells/mm 3 in 2014 (p < 0.001), and the proportion of late ART initiation decreased from 80% to 45% (p < 0.001). The risk factors for late ART initiation were male gender, heterosexual transmission and older age (>30 years) (p < 0.001). Notable improvements were made in the median CD4 cell count at ART initiation and the proportion of late ART initiation from 2008 to 2014. However, persons with high risk of HIV exposure who are male, older even heterosexual orientation should be given more opportunities to receive frequently screening, earlier diagnoses and timely treatment.

  15. Coronary Stent Artifact Reduction with an Edge-Enhancing Reconstruction Kernel - A Prospective Cross-Sectional Study with 256-Slice CT.

    PubMed

    Tan, Stéphanie; Soulez, Gilles; Diez Martinez, Patricia; Larrivée, Sandra; Stevens, Louis-Mathieu; Goussard, Yves; Mansour, Samer; Chartrand-Lefebvre, Carl

    2016-01-01

    Metallic artifacts can result in an artificial thickening of the coronary stent wall which can significantly impair computed tomography (CT) imaging in patients with coronary stents. The objective of this study is to assess in vivo visualization of coronary stent wall and lumen with an edge-enhancing CT reconstruction kernel, as compared to a standard kernel. This is a prospective cross-sectional study involving the assessment of 71 coronary stents (24 patients), with blinded observers. After 256-slice CT angiography, image reconstruction was done with medium-smooth and edge-enhancing kernels. Stent wall thickness was measured with both orthogonal and circumference methods, averaging thickness from diameter and circumference measurements, respectively. Image quality was assessed quantitatively using objective parameters (noise, signal to noise (SNR) and contrast to noise (CNR) ratios), as well as visually using a 5-point Likert scale. Stent wall thickness was decreased with the edge-enhancing kernel in comparison to the standard kernel, either with the orthogonal (0.97 ± 0.02 versus 1.09 ± 0.03 mm, respectively; p<0.001) or the circumference method (1.13 ± 0.02 versus 1.21 ± 0.02 mm, respectively; p = 0.001). The edge-enhancing kernel generated less overestimation from nominal thickness compared to the standard kernel, both with the orthogonal (0.89 ± 0.19 versus 1.00 ± 0.26 mm, respectively; p<0.001) and the circumference (1.06 ± 0.26 versus 1.13 ± 0.31 mm, respectively; p = 0.005) methods. The edge-enhancing kernel was associated with lower SNR and CNR, as well as higher background noise (all p < 0.001), in comparison to the medium-smooth kernel. Stent visual scores were higher with the edge-enhancing kernel (p<0.001). In vivo 256-slice CT assessment of coronary stents shows that the edge-enhancing CT reconstruction kernel generates thinner stent walls, less overestimation from nominal thickness, and better image quality scores than the standard kernel.

  16. Optimal Measurement Level and Ulnar Nerve Cross-Sectional Area Cutoff Threshold for Identifying Ulnar Neuropathy at the Elbow by MRI and Ultrasonography.

    PubMed

    Terayama, Yasushi; Uchiyama, Shigeharu; Ueda, Kazuhiko; Iwakura, Nahoko; Ikegami, Shota; Kato, Yoshiharu; Kato, Hiroyuki

    2018-06-01

    Imaging criteria for diagnosing compressive ulnar neuropathy at the elbow (UNE) have recently been established as the maximum ulnar nerve cross-sectional area (UNCSA) upon magnetic resonance imaging (MRI) and/or ultrasonography (US). However, the levels of maximum UNCSA and diagnostic cutoff values have not yet been established. We therefore analyzed UNCSA by MRI and US in patients with UNE and in controls. We measured UNCSA at 7 levels in 30 patients with UNE and 28 controls by MRI and at 15 levels in 12 patients with UNE and 24 controls by US. We compared UNCSA as determined by MRI or US and determined optimal diagnostic cutoff values based on receiver operating characteristic curve analysis. The UNCSA was significantly larger in the UNE group than in controls at 3, 2, 1, and 0 cm proximal and 1, 2, and 3 cm distal to the medial epicondyle for both modalities. The UNCSA was maximal at 1 cm proximal to the medial epicondyle for MRI (16.1 ± 3.5 mm 2 ) as well as for US (17 ± 7 mm 2 ). A cutoff value of 11.0 mm 2 for MRI and US was found to be optimal for differentiating between patients with UNE and controls, with an area under the receiver operating characteristic curve of 0.95 for MRI and 0.96 for US. The UNCSA measured by MRI was not significantly different from that by US. Intra-rater and interrater reliabilities for UNCSA were all greater than 0.77. The UNCSA in the severe nerve dysfunction group of 18 patients was significantly larger than that in the mild nerve dysfunction group of 12 patients. By measuring UNCSA with MRI or US at 1 cm proximal to the ME, patients with and without UNE could be discriminated at a cutoff threshold of 11.0 mm 2 with high sensitivity, specificity, and reliability. Diagnostic III. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  17. Blood pressure measurements in the ankle are not equivalent to blood pressure measurements in the arm.

    PubMed

    Goldstein, Lara Nicole; Wells, Mike; Sliwa, Karen

    2014-07-25

    Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically relevant (i.e. a difference of ≥10 mmHg). This was a prospective cross-sectional study in an urban ED making use of a convenience sample of 201 patients (18 - 50 years of age) who were not in need of emergency medical treatment. BP was measured in the supine position on both arms and ankles with the correct size cuff according to the manufacturer's guidelines. The arm and ankle BP measurements were compared. There was a clinically and statistically significant difference between arm and ankle systolic BP (SBP) and mean arterial pressure (MAP) (-13 mmHg, 95% confidence interval (CI) -28 - 1 mmHg and -5 mmHg, 95% CI -13 - 4 mmHg, respectively), with less difference in diastolic BP (DBP) (2 mmHg, 95% CI -7 - 10 mmHg). Only 37% of SBP measurements and 83% of MAP measurements were within an error range of 10 mmHg, while 95% of DBP measurements agreed within 10 mmHg. While the average differences (or the bias) were generally not large, large variations in individual patients (indicating poor precision) made the prediction of arm BP from ankle measurements unreliable. Ankle BP cannot be used as a substitute for arm BP in the ED.

  18. Assessment of haematological parameters in HIV-infected and uninfected Rwandan women: a cross-sectional study

    PubMed Central

    Munyazesa, Elisaphane; Emile, Ivan; Mutimura, Eugene; Hoover, Donald R; Shi, Qiuhu; McGinn, Aileen P; Musiime, Stephenson; Muhairwe, Fred; Rutagengwa, Alfred; Dusingize, Jean Claude; Anastos, Kathryn

    2012-01-01

    Objectives Although haematological abnormalities are common manifestations of HIV infection, few studies on haematological parameters in HIV-infected persons have been undertaken in sub-Saharan Africa. The authors assessed factors associated with haematological parameters in HIV-infected antiretroviral-naïve and HIV-uninfected Rwandan women. Study design Cross-sectional analysis of a longitudinal cohort. Setting Community-based women's associations. Participants 710 HIV-infected (HIV+) antiretroviral-naïve and 226 HIV-uninfected (HIV−) women from the Rwanda Women's Interassociation Study Assessment. Haematological parameters categorised as (abnormal vs normal) were compared by HIV status and among HIV+ women by CD4 count category using proportions. Multivariate logistic regression models using forward selection were fit. Results Prevalence of anaemia (haemoglobin (Hb) <12.0 g/dl) was higher in the HIV+ group (20.5% vs 6.3%; p<0.001), and increased with lower CD4 counts: ≥350 (7.6%), 200–349 (16%) and <200 cells/mm3 (32.2%). Marked anaemia (Hb <10.0 g/dl) was found in 4.2% of HIV+ and none of the HIV− women (p<0.001), and was highest in HIV+ women with CD4 <200 cells/mm3 (8.4%). The HIV+ were more likely than HIV− women (4.2 vs 0.5%, respectively, p=0.002) to have moderate neutropenia with white blood cells <2.0×103 cells/mm3 and 8.4% of HIV+ women with CD4 <200 cells/mm3 had moderate neutropenia. In multivariate logistic regression analysis, BMI (OR 0.87/kg/m2, 95% CI 0.82 to 0.93; p<0.001), CD4 200–350 vs HIV− (OR 3.59, 95% CI 1.89 to 6.83; p<0.001) and CD4 <200 cells/mm3 vs HIV− (OR 8.09, 95% CI 4.37 to 14.97; <0.001) had large independent associations with anaemia. There were large independent associations of CD4 <200 cells/mm3 vs HIV− (OR 7.18, 95% CI 0.78 to 65.82; p=0.081) and co-trimoxazole and/or dapsone use (OR 5.69, 95% CI 0.63 to 51.45; p=0.122) with moderate neutropenia. Conclusions Anaemia was more common than neutropenia or thrombocytopenia in the HIV-infected Rwandan women. Future comparisons of haematological parameters in HIV-infected patients before and after antiretroviral therapy initiation are warranted. PMID:23169875

  19. Stability of radial head and neck fractures: a biomechanical study of six fixation constructs with consideration of three locking plates.

    PubMed

    Burkhart, Klaus Josef; Mueller, Lars P; Krezdorn, David; Appelmann, Philipp; Prommersberger, Karl J; Sternstein, Werner; Rommens, Pol M

    2007-12-01

    Open reduction and internal fixation of radial neck fractures can lead to secondary loss of reduction and nonunion due to insufficient stability. Nevertheless, there are only a few biomechanical studies about the stability achieved by different osteosynthesis constructs. Forty-eight formalin-fixed, human proximal radii were divided into 6 groups according to their bone density (measured by dual-energy x-ray absorptiometry). A 2.7-mm gap osteotomy was performed to simulate an unstable radial neck fracture, which was fixed with 3 nonlocking implants: a 2.4-mm T plate, a 2.4-mm blade plate, and 2.0-mm crossed screws, and 3 locking plates: a 2.0-mm LCP T plate, a 2.0-mm 6x2 grid plate, and a 2.0-mm radial head plate. Implants were tested under axial (N/mm) and torsional (Ncm/ degrees ) loads with a servohydraulic materials testing machine. The radial head plate was significantly stiffer than all other implants under axial as well as under torsional loads, with values of 36 N/mm and 13 Ncm/ degrees . The second-stiffest implant was the blade plate, with values of 20 N/mm and 6 Ncm/ degrees . The weakest implants were the 2.0-mm LCP, with values of 6 N/mm and 2 Ncm/ degrees , and the 2.0-mm crossed screws, with values of 18 N/mm and 2 Ncm/ degrees . The 2.4-mm T plate, with values of 14 N/mm and 4 Ncm/ degrees , and the 2.0-mm grid plate, with values of 8 N/mm and 4 Ncm/ degrees came to lie in the midfield. The 2.0-mm angle-stable plates-depending on their design-allow fixation with comparable or even higher stability than the bulky 2.4-mm nonlocking implants and 2.0-mm crossed screws.

  20. Morphometric analysis of pulp size in maxillary permanent central incisors correlated with age: An indirect digital study.

    PubMed

    Ravindra, S V; Mamatha, G P; Sunita, J D; Balappanavar, Aswini Y; Sardana, Varun

    2015-01-01

    Teeth are hardest part of the body and are least affected by the taphonomic process. They are considered as one of the reliable methods of identification of a person in forensic sciences. The aim of the following study is to establish morphometeric measurements by AutoCad 2009 (Autodesk, Inc) of permanent maxillary central incisors in different age groups of Udaipur population. Hospital-based descriptive cross-sectional study carried out in Udaipur. A study was carried out on 308 subjects of both genders with the age range of 9-68 years. Standardized intra-oral radiographs were made by paralleling technique and processed. The radiographs were scanned and the obtained images were standardized to the actual size of radiographic film. This was followed by measuring them using software AutoCad 2009. F-test, post-hoc test, Pearson's correlation test. For left maxillary central incisor, the total pulp area was found to be of 38.41 ± 12.88 mm and 14.32 ± 7.04 mm respectively. For right maxillary central incisor, the total pulp size was 38.39 ± 14.95 mm and 12.35 ± 5 mm respectively. Males (32.50, 32.87 mm(2)) had more pulp area when compared with females (28.82, 30.05 mm(2)). There was a decrease in total pulp area with increasing age which may be attributed to secondary dentin formation.

  1. Comparative Evaluation of the Ostium After External and Nonendoscopic Endonasal Dacryocystorhinostomy Using Image Processing (Matlabs and Image J) Softwares.

    PubMed

    Ganguly, Anasua; Kaza, Hrishikesh; Kapoor, Aditya; Sheth, Jenil; Ali, Mohammad Hasnat; Tripathy, Devjyoti; Rath, Suryasnata

    The purpose of this study was to compare the characteristics of the ostium after external dacryocystorhinostomy and nonendoscopic endonasal dacryocystorhinostomy (NEN-DCR). This cross-sectional study included patients who underwent a successful external dacryocystorhinostomy or NEN-DCR and had ≥1 month follow up. Pictures of the ostium were captured with a nasal endoscope (4 mm, 30°) after inserting a lacrimal probe premarked at 2 mm. Image analyses were performed using Image J and Contour softwares. Of the 113 patients included, external dacryocystorhinostomy group had 53 patients and NEN-DCR group had 60 patients. The mean age of patients in the NEN-DCR group (38 years) was significantly (p < 0.05) lower than the external dacryocystorhinostomy group (50 years). There was no statistically significant difference (2 sample t test, p > 0.05) in mean follow up (6 vs. 4 months), maximum diameter of ostium (8 vs. 7 mm), perpendicular drawn to it (4 vs. 4 mm), area of ostium (43 vs. 36 mm), and the minimum distance between common internal punctum and edge of the ostium (1 vs. 1 mm) between the external and NEN-DCR groups. Image processing softwares offer simple and objective method to measure the ostium. While ostia are comparable in size, their relative position differs with posteriorly placed ostia in external compared with inferior in NEN-DCR.

  2. Effects of tool handle dimension and workpiece orientation and size on wrist ulnar/radial torque strength, usability and discomfort in a wrench task.

    PubMed

    Dianat, Iman; Rahimi, Soleyman; Nedaei, Moein; Asghari Jafarabadi, Mohammad; Oskouei, Ali E

    2017-03-01

    The effects of tool handle dimension (three modified designs of wrenches with 30-50 mm diameter cylindrical handles and traditional design with rectangular cross-sectional (5 mm × 25 mm) handle), workpiece orientation (vertical/horizontal) and workpiece size (small/large) as well as user's hand size on wrist ulnar/radial (U/R) torque strength, usability and discomfort, and also the relationship between these variables were evaluated in a maximum torque task using wrenches. The highest and lowest levels of maximal wrist U/R torque strength were recorded for the 30 mm diameter handle and traditional wrench design, respectively. The prototype handle with 30 mm diameter, together with 40 mm diameter handle, was also better than other designs as they received higher usability ratings and caused less discomfort. The mean wrist torque strength exerted on a vertically oriented workpiece (in the sagittal plane) was 23.8% higher than that exerted on a horizontally oriented one (in the transverse plane). The user's hand size had no effect on torque exertions. The wrist torque strength and usability were negatively correlated with hand and finger discomfort ratings. The results are also discussed in terms of their implications for hand tool and workstation configuration in torque tasks involving wrenches. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Reference charts for fetal biometric parameters in twin pregnancies according to chorionicity.

    PubMed

    Araujo Júnior, Edward; Ruano, Rodrigo; Javadian, Pouya; Martins, Wellington P; Elito, Julio; Pires, Claudio Rodrigues; Zanforlin Filho, Sebastião Marques

    2014-04-01

    The objective of this article is to determine reference values for fetal biometric parameters in twin pregnancies and to compare these values between monochorionic and dichorionic pregnancies. A retrospective cross-sectional study was conducted among 157 monochorionic and 176 dichorionic twin pregnancies between 14 and 38 weeks of gestation. Biometric measurements included the biparietal diameter (BPD), abdominal circumference (AC), femurs length (FL) and estimated fetal weight (EFW). To evaluate the correlation between biometric parameters and gestational age, polynomial regression models were created, with adjustments using the coefficient of determination (R(2) ). Comparison between monochorionic and dichorionic pregnancies was performed using analysis of covariance. The mean BPD, AC, FL and EFW for the dichorionic pregnancies were 56.16 mm, 191.1 mm, 41.08 mm and 816.1 g, respectively. The mean BPD, AC, FL and EFW for the monochorionic pregnancies were 57.14 mm, 184.2 mm, 39.29 mm and 723.4 g, respectively. There was a statistical difference between mono and dichorionic pregnancies for all the biometric parameters (BPD p = 0.012; AC p = 0.047; FL p = 0.007; EFW p = 0.011). Reference curves of biometric parameters in twin pregnancies were determined. Biometric parameters were statistically different between monochorionic and dichorionic pregnancies. © 2014 John Wiley & Sons, Ltd.

  4. Magnetic resonance imaging, computed tomography, and gross anatomy of the canine tarsus.

    PubMed

    Deruddere, Kirsten J; Milne, Marjorie E; Wilson, Kane M; Snelling, Sam R

    2014-11-01

    To describe the normal anatomy of the soft tissues of the canine tarsus as identified on computed tomography (CT) and magnetic resonance imaging (MRI) and to evaluate specific MRI sequences and planes for observing structures of diagnostic interest. Prospective descriptive study. Canine cadavers (n = 3). A frozen cadaver pelvic limb was used to trial multiple MRI sequences using a 1.5 T superconducting magnet and preferred sequences were selected. Radiographs of 6 canine cadaver pelvic limbs confirmed the tarsi were radiographically normal. A 16-slice CT scanner was used to obtain 1 mm contiguous slices through the tarsi. T1-weighted, proton density with fat suppression (PD FS) and T2-weighted MRI sequences were obtained in the sagittal plane, T1-weighted, and PD FS sequences in the dorsal plane and PD FS sequences in the transverse plane. The limbs were frozen for one month and sliced into 4-5 mm thick frozen sections. Anatomic sections were photographed and visually correlated to CT and MR images. Most soft tissue structures were easiest to identify on the transverse MRI sections with cross reference to either the sagittal or dorsal plane. Bony structures were easily identified on all CT, MR, and gross sections. The anatomy of the canine tarsus can be readily identified on MR imaging. © Copyright 2014 by The American College of Veterinary Surgeons.

  5. Paleoseismology of the Southern Section of the Black Mountains and Southern Death Valley Fault Zones, Death Valley, United States

    USGS Publications Warehouse

    Sohn, Marsha S.; Knott, Jeffrey R.; Mahan, Shannon

    2014-01-01

    The Death Valley Fault System (DVFS) is part of the southern Walker Lane–eastern California shear zone. The normal Black Mountains Fault Zone (BMFZ) and the right-lateral Southern Death Valley Fault Zone (SDVFZ) are two components of the DVFS. Estimates of late Pleistocene-Holocene slip rates and recurrence intervals for these two fault zones are uncertain owing to poor relative age control. The BMFZ southernmost section (Section 1W) steps basinward and preserves multiple scarps in the Quaternary alluvial fans. We present optically stimulated luminescence (OSL) dates ranging from 27 to 4 ka of fluvial and eolian sand lenses interbedded with alluvial-fan deposits offset by the BMFZ. By cross-cutting relations, we infer that there were three separate ground-rupturing earthquakes on BMFZ Section 1W with vertical displacement between 5.5 m and 2.75 m. The slip-rate estimate is ∼0.2 to 1.8 mm/yr, with an earthquake recurrence interval of 4,500 to 2,000 years. Slip-per-event measurements indicate Mw 7.0 to 7.2 earthquakes. The 27–4-ka OSL-dated alluvial fans also overlie the putative Cinder Hill tephra layer. Cinder Hill is offset ∼213 m by SDVFZ, which yields a tentative slip rate of 1 to 8 mm/yr for the SDVFZ.

  6. The Thermoluminescence Response of Ge-Doped Flat Fibers to Gamma Radiation

    PubMed Central

    Mat Nawi, Siti Nurasiah Binti; Wahib, Nor Fadira Binti; Zulkepely, Nurul Najua Binti; Amin, Yusoff Bin Mohd; Min, Ung Ngie; Bradley, David Andrew; Md Nor, Roslan Bin; Maah, Mohd Jamil

    2015-01-01

    Study has been undertaken of the thermoluminescence (TL) yield of various tailor-made flat cross-section 6 mol% Ge-doped silica fibers, differing only in respect of external dimensions. Key TL dosimetric characteristics have been investigated, including glow curves, dose response, sensitivity, fading and reproducibility. Using a 60Co source, the samples were irradiated to doses within the range 1 to 10 Gy. Prior to irradiation, the flat fibers were sectioned into 6 mm lengths, weighed, and annealed at 400 °C for 1 h. TL readout was by means of a Harshaw Model 3500 TLD reader, with TLD-100 chips (LiF:Mg, Ti) used as a reference dosimeter to allow the relative response of the fibers to be evaluated. The fibers have been found to provide highly linear dose response and excellent reproducibility over the range of doses investigated, demonstrating high potential as TL-mode detectors in radiation medicine applications. Mass for mass, the results show the greatest TL yield to be provided by fibers of the smallest cross-section, analysis indicating this to be due to minimal light loss in transport of the TL through the bulk of the silica medium. PMID:26307987

  7. Estimation of relative permeability and capillary pressure from mass imbibition experiments

    NASA Astrophysics Data System (ADS)

    Alyafei, Nayef; Blunt, Martin J.

    2018-05-01

    We perform spontaneous imbibition experiments on three carbonates - Estaillades, Ketton, and Portland - which are three quarry limestones that have very different pore structures and span wide range of permeability. We measure the mass of water imbibed in air saturated cores as a function of time under strongly water-wet conditions. Specifically, we perform co-current spontaneous experiments using a highly sensitive balance to measure the mass imbibed as a function of time for the three rocks. We use cores measuring 37 mm in diameter and three lengths of approximately 76 mm, 204 mm, and 290 mm. We show that the amount imbibed scales as the square root of time and find the parameter C, where the volume imbibed per unit cross-sectional area at time t is Ct1/2. We find higher C values for higher permeability rocks. Employing semi-analytical solutions for one-dimensional flow and using reasonable estimates of relative permeability and capillary pressure, we can match the experimental data. We finally discuss how, in combination with conventional measurements, we can use theoretical solutions and imbibition measurements to find or constrain relative permeability and capillary pressure.

  8. Radial distribution of the contributions to band broadening of a silica-based semi-preparative monolithic column.

    PubMed

    Abia, Jude A; Mriziq, Khaled S; Guiochon, Georges A

    2009-04-01

    Using an on-column local electrochemical microdetector operated in the amperometric mode, band elution profiles were recorded at different radial locations at the exit of a 10 mm id, 100 mm long silica-based monolithic column. HETP plots were then acquired at each of these locations, and all these results were fitted to the Knox equation. This provided a spatial distribution of the values of the eddy diffusion (A), the molecular diffusion (B), and the resistance to the kinetics of mass transfer (C) terms. Results obtained indicate that the wall region yields higher A values and smaller C values than the central core region. Significant radial fluctuations of these contributions to band broadening occur throughout the exit column cross-section. This phenomenon is due to the structural radial heterogeneity of the column.

  9. Measurements of Thermal Conductivity of Superfluid Helium Near its Transition Temperature T(sub lambda) in a 2D Confinement

    NASA Technical Reports Server (NTRS)

    Jerebets, Sergei

    2004-01-01

    We report our recent experiments on thermal conductivity measurements of superfluid He-4 near its phase transition in a two-dimensional (2D) confinement under saturated vapor pressure. A 2D confinement is created by 2-mm- and 1-mm-thick glass capillary plates, consisting of densely populated parallel microchannels with cross-sections of 5 x 50 and 1 x 10 microns, correspondingly. A heat current (2 < Q < 400 nW/sq cm) was applied along the channels long direction. High-resolution measurements were provided by DC SQUID-based high-resolution paramagnetic salt thermometers (HRTs) with a nanokelvin resolution. We might find that thermal conductivity of confined helium is finite at the bulk superfluid transition temperature. Our 2D results will be compared with those in a bulk and 1D confinement.

  10. [Pilot study of antiretroviral therapy in Djibouti].

    PubMed

    Ahmed, A A; Latoundji, S

    2007-01-01

    A cross-sectional survey was conducted among 112 HIV positive patients who had received antiretroviral therapy for >3 months to assess the efficacy of treatment (viral load <400 copies/mL). The median age at enrolment was 36 years, 90% of patients were at the AIDS stage and median CD4 rate was 118/mm3. Patients received a combined treatment of 2 NRTI +1 NNRTI (51%), 3 NRTI (45%) and 2 NRTI+1 PI (4%). Virological efficacy was seen in 74% of the patients, irrespective of the prescribed protocol and the initial clinical and immunological profile. Mean improvements measured were 20% on the Karnofsky index (KI), 2.1 kg/m2 in body mass index and 82 cells/mm in CD4. The prevalence of side effects was 84%. The predictors for treatment success were quality of care and KI > 70%.

  11. Upgrade of absolute extreme ultraviolet diagnostic on J-TEXT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, X. L.; Cheng, Z. F., E-mail: chengfe@hust.edu.cn; Hou, S. Y.

    The absolute extreme ultraviolet (AXUV) diagnostic system is used for radiation observation on J-TEXT tokamak [J. Zhang, G. Zhuang, Z. J. Wang, Y. H. Ding, X. Q. Zhang, and Y. J. Tang, Rev. Sci. Instrum. 81, 073509 (2010)]. The upgrade of the AXUV system is aimed to improve the spatial resolution and provide a three-dimensional image on J-TEXT. The new system consists of 12 AXUV arrays (4 AXUV16ELG arrays, 8 AXUV20ELG arrays). The spatial resolution in the cross-section is 21 mm for the AXUV16ELG arrays and 17 mm for the AXUV20ELG arrays. The pre-amplifier is also upgraded for a highermore » signal to noise ratio. By upgrading the AXUV imaging system, a more accurate observation on the radiation information is obtained.« less

  12. Automated pinhole-aperture diagnostic for the current profiling of TWT electron beams

    NASA Astrophysics Data System (ADS)

    Wei, Yu-Xiang; Huang, Ming-Guang; Liu, Shu-Qing; Liu, Jin-Yue; Hao, Bao-Liang; Du, Chao-Hai; Liu, Pu-Kun

    2013-02-01

    The measurement system reported here is intended for use in determining the current density distribution of electron beams from Pierce guns for use in TWTs. The system was designed to automatically scan the cross section of the electron beam and collect the high-resolution data with a Faraday cup probe mounted on a multistage manipulator using the LabVIEW program. A 0.06 mm thick molybdenum plate with a pinhole and a Faraday cup mounted as a probe assembly was employed to sample the electron beam current with 0.5 µm space resolution. The thermal analysis of the probe with pulse beam heating was discussed. A 0.45 µP electron gun with the expected minimum beam radius 0.42 mm was measured and the three-dimensional current density distribution, beam envelope and phase space were presented.

  13. Effects of Intracranial Trochlear Neurectomy on the Structure of the Primate Superior Oblique Muscle

    PubMed Central

    Poukens, Vadims; Ying, Howard; Shan, Xiaoyan; Tian, Jing; Zee, David S.

    2010-01-01

    Purpose. Although cyclovertical strabismus in humans is frequently attributed to superior oblique (SO) palsy, anatomic effects of SO denervation have not been studied. Magnetic resonance imaging (MRI) and orbital histology was used to study the effects of acute trochlear (CN4) denervation on the monkey SO. Methods. Five juvenile macaque monkeys were perfused with formalin for 5 weeks: 15 months after unilateral or bilateral 10-mm intracranial trochlear neurectomy. Denervated and fellow orbits were imaged by MRI, embedded whole in paraffin, serially sectioned at 10-μm thickness, and stained with Masson trichrome. Whole muscle and individual fiber cross sections were quantified in SO muscles throughout the orbit and traced larger fibers in one specimen where they were present. Results. MRI demonstrated marked reduction in midorbital cross section in denervated SO muscles, with anterior shift of SO mass preserving overall volume. Muscle fibers exhibited variable atrophy along their lengths. Denervated orbital layer (OL) fiber cross sections were slightly but significantly reduced from control at most anteroposterior locations, but this reduction was much more profound in global layer (GL) fibers. Intraorbital and intramuscular CN4 were uniformly fibrotic. In one animal, there were scattered clusters of markedly hypertrophic GL fibers that exhibited only sparse myomyous junctions only anteriorly. Conclusions. CN4 denervation produces predominantly SO GL atrophy with relative OL sparing. Overall midorbital SO atrophy was evident by MRI as early as 5 weeks after denervation, as denervated SO volume shifted anteriorly. Occasional GL fiber hypertrophy suggests that at least some SO fibers extend essentially the full muscle length after trochlear neurectomy. PMID:20164458

  14. Spectral Analysis of the Shuttle Glow. SPAS II/IBSS Mission - AIS hardware

    DTIC Science & Technology

    1992-04-23

    Mirror Lens C Reflection) CiraCylindrical/-Lens • Plane Mirror j _Slit Slit Mro Fig. 7. Cross section through the reflective foreoptics of the UV Fig. 6...selection. The gratings in the The slit width of 0.045 mm restricted the angular spectrograph are deposited on Zerodur blanks, which width of the FOV...of th*i short fee-1 hlaa, t do, lmw b*WdW 3Wa APO=E OPTIC I VOL 31, ft. 16 1 1~ toes I 48 Secondary Mlirror Primary Mirror - lntaeranas Ptten Image

  15. Two-phase flow in short horizontal rectangular microchannels with a height of 300 μm

    NASA Astrophysics Data System (ADS)

    Chinnov, E. A.; Ron'shin, F. V.; Kabov, O. A.

    2015-09-01

    The two-phase flow in a narrow short horizontal channel with a rectangular cross section is studied experimentally. The channel has a width of 10, 20, or 30 mm and a height of 300 μm. The specifics of formation of such two-phase flows are investigated. It is demonstrated that the regions of bubble and churn flow regimes grow and constrain the region of jet flow as the channel gets wider. The boundaries of the regions of annular and stratified flow regimes remain almost unaltered.

  16. A Flow-Channel Analysis for the Mars Hopper

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    W. Spencer Cooley

    The Mars Hopper is an exploratory vehicle designed to fly on Mars using carbon dioxide from the Martian atmosphere as a rocket propellant. The propellent gasses are thermally heated while traversing a radioisotope ther- mal rocket (RTR) engine’s core. This core is comprised of a radioisotope surrounded by a heat capacitive material interspersed with tubes for the propellant to travel through. These tubes, or flow channels, can be manu- factured in various cross-sectional shapes such as a special four-point star or the traditional circle. Analytical heat transfer and computational fluid dynamics (CFD) anal- yses were performed using flow channels withmore » either a circle or a star cross- sectional shape. The nominal total inlet pressure was specified at 2,805,000 Pa; and the outlet pressure was set to 2,785,000 Pa. The CO2 inlet tem- perature was 300 K; and the channel wall was 1200 K. The steady-state CFD simulations computed the smooth-walled star shape’s outlet temper- ature to be 959 K on the finest mesh. The smooth-walled circle’s outlet temperature was 902 K. A circle with a surface roughness specification at 0.01 mm gave 946 K and at 0.1 mm yielded 989 K. The The effects of a slightly varied inlet pressure were also examined. The analytical calculations were based on the mass flow rates computed in the CFD simulations and provided significantly higher outlet temperature results while displaying the same comparison trends. Research relating to the flow channel heat transfer studies was also done. Mathematical methods to geometrically match the cross-sectional areas of the circle and star, along with a square and equilateral triangle, were derived. A Wolfram Mathematica 8 module was programmed to analyze CFD results using Richardson Extrapolation and calculate the grid convergence index (GCI). A Mathematica notebook, also composed, computes and graphs the bulk mean temperature along a flow channel’s length while the user dynam- ically provides the input variables, allowing their effects on the temperature to be more easily observed.« less

  17. Effect of archwire cross-section changes on force levels during complex tooth alignment with conventional and self-ligating brackets.

    PubMed

    Montasser, Mona A; Keilig, Ludger; El-Bialy, Tarek; Reimann, Susanne; Jäger, Andreas; Bourauel, Christoph

    2015-04-01

    Our objective was to investigate the effect of archwire cross-section increases on the levels of force applied to teeth during complex malalignment correction with various archwire-bracket combinations using an experimental biomechanical setup. The study comprised 3 types of orthodontic brackets: (1) conventional ligating brackets (Victory Series [3M Unitek, Monrovia, Calif] and Mini-Taurus [Rocky Mountain Orthodontics, Denver, Colo]), (2) self-ligating brackets (SmartClip, a passive self-ligating bracket [3M Unitek]; and Time3 [Rocky Mountain Orthodontics, Denver, Colo] and SPEED [Strite Industries, Cambridge, Ontario, Canada], both active self-ligating brackets), and (3) a conventional low-friction bracket (Synergy [Rocky Mountain Orthodontics]). All brackets had a nominal 0.022-in slot size. The brackets were combined with 0.014-in and 0.016-in titanium memory wires, Therma-Ti archwires (American Orthodontics, Sheboygan, Wis). The archwires were tied to the conventional brackets with both stainless steel ligatures of size 0.010-in and elastomeric rings. A malocclusion of the maxillary central incisor displaced 2 mm gingivally (x-axis) and 2 mm labially (z-axis) was simulated. The forces recorded when using the 0.014-in archwires ranged from 1.7 ± 0.1 to 5.0 ± 0.3 N in the x-axis direction, and from 1.2 ± 0.1 to 5.5 ± 0.3 N in the z-axis direction. When we used the 0.016-in archwires, the forces ranged from 2.6 ± 0.1 to 6.0 ± 0.3 N in the x-axis direction, and from 2.0 ± 0.2 to 6.0 ± 0.4 N in the z-axis direction. Overall, the increases ranged from 16.0% to 120.0% in the x-axis and from 10.4% to 130.0% in the z-axis directions. Increasing the cross section of the wire increased the force level invariably with all brackets. Wires of size 0.014 in produced relatively high force levels, and the force level increased with 0.016-in wires. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  18. Nuclear design analysis of square-lattice honeycomb space nuclear rocket engine

    NASA Astrophysics Data System (ADS)

    Widargo, Reza; Anghaie, Samim

    1999-01-01

    The square-lattice honeycomb reactor is designed based on a cylindrical core that is determined to have critical diameter and length of 0.50 m and 0.50 c, respectively. A 0.10-cm thick radial graphite reflector, in addition to a 0.20-m thick axial graphite reflector are used to reduce neutron leakage from the reactor. The core is fueled with solid solution of 93% enriched (U, Zr, Nb)C, which is one of several ternary uranium carbides that are considered for this concept. The fuel is to be fabricated as 2 mm grooved (U, Zr, Nb)C wafers. The fuel wafers are used to form square-lattice honeycomb fuel assemblies, 0.10 m in length with 30% cross-sectional flow area. Five fuel assemblies are stacked up axially to form the reactor core. Based on the 30% void fraction, the width of the square flow channel is about 1.3 mm. The hydrogen propellant is passed through these flow channels and removes the heat from the reactor core. To perform nuclear design analysis, a series of neutron transport and diffusion codes are used. The preliminary results are obtained using a simple four-group cross-section model. To optimize the nuclear design, the fuel densities are varied for each assembly. Tantalum, hafnium and tungsten are considered and used as a replacement for niobium in fuel material to provide water submersion sub-criticality for the reactor. Axial and radial neutron flux and power density distributions are calculated for the core. Results of the neutronic analysis indicate that the core has a relatively fast spectrum. From the results of the thermal hydraulic analyses, eight axial temperature zones are chosen for the calculation of group average cross-sections. An iterative process is conducted to couple the neutronic calculations with the thermal hydraulics calculations. Results of the nuclear design analysis indicate that a compact core can be designed based on ternary uranium carbide square-lattice honeycomb fuel. This design provides a relatively high thrust to weight ratio.

  19. Dairy product intake and bone properties in 70-year-old men and women.

    PubMed

    Hallkvist, Olle M; Johansson, Jonas; Nordström, Anna; Nordström, Peter; Hult, Andreas

    2018-01-29

    In the present population-based study including 70-year-old men and women, total dairy product intake was associated with a weak positive association with tibia trabecular and cortical cross-sectional areas. Milk consumption has recently been suggested to increase fracture risk. Therefore, we aimed to investigate associations between dairy product consumption and peripheral bone properties. Furthermore, we explored whether consumption of milk and fermented dairy products affected bone properties differently. The Healthy Aging Initiative is a population-based, cross-sectional study investigating the health of 70-year-old men and women. Out of the 2904 individuals who met the inclusion criteria, data on self-reported daily dairy product consumption (dl/day), peripheral quantitative computed tomography (pQCT) examinations at the 4 and 66% scan sites of the tibia and radius, and dual-energy X-ray absorptiometry (DXA) scans were collected from 2040 participants. Associations between dairy product consumption and bone properties were examined using multiple linear regression models adjusted for sex, muscle area, meal size, dietary protein proportion, current smoking status, and objectively measured physical activity. Total dairy product intake was associated with larger trabecular (2.296 (95% CI, 0.552-4.039) mm 2 , per dl/day increase, p = 0.01) and cortical cross-sectional areas (CSAs) in the tibia (1.757 (95% CI, 0.683-2.830 mm 2 , p = 0.001) as measured by pQCT and higher areal bone mineral density (aBMD) of the radius (3.231 (95% CI, 0.764-5.698) mg/cm 2 , p = 0.01) as measured by DXA. No other measurement in the tibia, radius, femoral neck, or lower spine was associated significantly with dairy product intake. Bone properties did not differ according to the type of dairy product consumed. No evidence of a negative association between dairy product consumption and bone health was found. Furthermore, total dairy product consumption was associated with increased CSAs in the tibia, regardless of dairy product type. Collectively, our findings indicate the existence of a weak but significant positive association between dairy product consumption bone properties in older adults.

  20. Update on diode-pumped solid-state laser experiments for inertial fusion energy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, C.; Smith, L.; Payne, S.

    The authors have completed the initial phase of the diode-pumped solid-state laser (DPSSL) experimental program to validate the expected pumping dynamics and extraction cross-sections of Yb{sup 3+}-doped Sr{sub 5}(PO{sub 4}){sub 3}F (Yb:S-FAP) crystals. Yb:S-FAP crystals up to 25 x 25 x 175 mm in size have been grown for this purpose which have acceptable loss characteristics (<1 %/cm) and laser damage thresholds ({approximately}20 J/cm{sup 2}). The saturation fluence for pumping has been measured to be 2.2 J/cm{sup 2} using three different methods based on either the spatial, temporal, or energy transmission properties of a Yb:S-FAP rod. The small signal gainmore » under saturated pumping conditions was measured. These measurements imply an emission cross section of 6.0 x 10{sup {minus}20} cm{sup 2} that falls within error bars of the previously reported value of 7.3 x 10{sup {minus}20} cm{sup 2}, obtained from purely spectroscopic techniques. The effects of radiation trapping on the emission lifetime have been quantified. The long lifetime of Yb:S-FAP has beneficial effects for diode-pumped amplifier designs, relative to materials with equivalent cross sections but shorter lifetimes, in that less peak pump intensity is required (thus lower diode costs) and that lower spontaneous emission rates lead to a reduction in amplified spontaneous emission. Consequently, up to 1.7 J/cm{sup 3} of stored energy density was achieved in a 6x6x44 mm Yb:S-FAP amplifier rod; this stored energy density is large relative to typical flashlamp-pumped Nd:glass values of 0.3 to 0.5 J/cm{sup 3}. A 2.4 kW peak power InGaAs diode array has been fabricated by Beach, Emanuel, and co-workers which meets the central wavelength, bandwidth, and energy specifications for the author`s immediate experiments. These results further increase their optimism of being able to produce a {approximately} 10% efficient diode-pumped solid state laser for inertial fusion energy.« less

  1. The effect of prophylaxis method on microtensile bond strength of indirect restorations to dentin.

    PubMed

    Soares, C J; Pereira, J C; Souza, S J B; Menezes, M S; Armstrong, S R

    2012-01-01

    The aim of this study was to evaluate the effect of different materials used for dentin prophylaxis on the microtensile bond strengths (μTBS) of adhesively cemented indirect composite restorations. Sixty bovine incisors had the buccal surface ground with wet #600-grit silicon carbide abrasive paper to obtain a flat exposed superficial dentin and were submitted to different prophylaxis protocols, as follows: 3% hydrogen peroxide (HydP); 0.12% chlorhexidine (Chlo); sodium bicarbonate jet (SodB); 50-μm aluminum oxide air abrasion (AirA); pumice paste (PumP), and control group-water spray (Cont). After prophylaxis protocols a resin composite block (3.0 mm × 5.0 mm × 5.0 mm) was adhesively cemented using dual resin cement (Rely X ARC). After 24 hours of water storage, specimens were serially sectioned perpendicular to the bonded interface into 1-mm-thick slices. Each specimen was trimmed with a diamond bur to an hourglass shape with a cross-sectional area of approximately 1.0 mm(2) at the bonded area. Specimens were tested (μTBS) at 0.5 mm/min using a universal testing machine. Scanning electron microscopy was used to examine the effects of prophylaxis techniques on dentin. Bond strength data (MPa) were analyzed by one-way analysis of variance and failure mode by Fisher test (α=0.05). μTBS data, means (SD), were (different superscripted letters indicate statistically significant differences): AirA, 25.2 (7.2)(a); PumP, 24.1 (7.8)(a); Chlo, 21.5 (5.6)(a); Cont, 20.6 (8.1)(a); HydP(,) 15.5 (7.6)(b); and SodB(,) 11.5 (4.4)(c). The use of aluminum oxide air abrasion, pumice paste, and chlorhexidine before acid etching did not significantly affect μTBS to dentin; however, the use of hydrogen peroxide and sodium bicarbonate jet significantly reduced μTBS.

  2. A user's manual for the Electromagnetic Surface Patch code: ESP version 3

    NASA Technical Reports Server (NTRS)

    Newman, E. H.; Dilsavor, R. L.

    1987-01-01

    This report serves as a user's manual for Version III of the Electromagnetic Surface Patch Code or ESP code. ESP is user-oriented, based on the method of moments (MM) for treating geometries consisting of an interconnection of thin wires and perfectly conducting polygonal plates. Wire/plate junctions must be about 0.1 lambda or more from any plate edge. Several plates may intersect along a common edge. Excitation may be by either a delta-gap voltage generator or by a plane wave. The thin wires may have finite conductivity and also may contain lumped loads. The code computes most of the usual quantities of interest such as current distribution, input impedance, radiation efficiency, mutual coupling, far zone gain patterns (both polarizations) and radar-cross-section (both/cross polarizations).

  3. Noninvasive pit and fissure sealing: microtensile bond strength to intact bovine enamel of different pit and fissure sealants in a simplified fissure model.

    PubMed

    Papacchini, Federica; Cury, Alvaro H; Goracci, Cecilia; Chieffi, Nicoletta; Tay, Franklin R; Polimeni, Antonella; Ferrari, Marco

    2006-12-01

    To measure the microtensile bond strength of different pit and fissure sealants in a simplified fissure model. Twenty extracted bovine mandibular permanent incisors were randomly divided into 4 groups for treatment: G1: 35% phosphoric acid/Clinpro Sealant; G2: 35% phosphoric acid/Delton; G3: Non-Rinse Conditioner/Dyract Seal; G4: 20% polyacrylic acid/Fuji IILC. Each tooth was sectioned into 6 pieces (4 x 6 mm) of buccal enamel. SEM examination was used to confirm the presence of aprismatic enamel on each tooth. Using a spacer, two pieces of etched enamel were secured to a glass slide at a mean distance of 0.6+/-0.1 mm. The space between enamel substrates was then etched/conditioned and sealed with different materials according to the tested groups. By serially cutting each double-bonded sample, multiple beam-shaped specimens about 0.8mm(2) in cross section were obtained and tested in tension (0.5 mm/min) until failure occurred at either one of the two stressed interfaces. Failure modes were classified by stereomicroscopy. G1 and G2 showed statistically higher bond strengths than G3 and G4. G4 demonstrated the significantly lowest bond strength. Failures were mostly adhesive in G1, G2, G3, and mainly cohesive/mixed in G4. According to this model, resin-based materials (Clinpro Sealant, Delton) showed better microtensile bond strength than compomer (Dyract Seal) or resin-modified glass ionomer (Fuji IILC).

  4. Osteonal effects on elastic modulus and fatigue life in equine bone.

    PubMed

    Gibson, V A; Stover, S M; Gibeling, J C; Hazelwood, S J; Martin, R B

    2006-01-01

    We hypothesized that recently formed, incompletely mineralized, and thus, relatively deformable osteons in the equine third metacarpus enhance in vitro load-controlled fatigue life in two ways. Macroscopically, there is a compliance effect, because reduced tissue elastic modulus diminishes the stress required to reach a given strain. Microscopically, there is a cement line effect, in which new osteons and their cement lines more effectively serve as barriers to crack propagation. We studied 18 4 x 10 x 100 mm beams from the medial, lateral, and dorsal cortices of metacarpal bones from 6 thoroughbred racehorses. Following load-controlled fatigue testing to fracture in 4 point bending, a transverse, 100 microm thick, basic fuchsin-stained cross-section was taken from the load-bearing region. The number and diameter of all intact (and thus recently formed/compliant) secondary osteons in a 3.8 x 3.8 mm region in the center of the section were determined. The associated area fraction and cement line length of intact osteons were calculated, and the relationships between these variables, elastic modulus (E), and the logarithm of fatigue life (logN(F)) were analyzed. As expected, logN(F) was negatively correlated with E, which was in turn negatively correlated with intact osteon area fraction and density. (LogN(F))/E increased in proportion to intact osteon density and nonlinearly with cement line density (mm/mm(2)). These results support the hypothesis that remodeling extends load-controlled fatigue life both through the creation of osteonal barriers to microdamage propagation and modulus reduction.

  5. Ocular biometric measurements in cataract surgery candidates in Portugal.

    PubMed

    Ferreira, Tiago B; Hoffer, Kenneth J; Ribeiro, Filomena; Ribeiro, Paulo; O'Neill, João G

    2017-01-01

    Describe the ocular biometric parameters and their associations in a population of cataract surgery candidates. A cross-sectional study of 13,012 eyes of 6,506 patients was performed. Biometric parameters of the eyes were measured by optical low-coherence reflectometry. The axial length (AL), mean keratometry (K) and astigmatism, anterior chamber depth (ACD) (epithelium to lens), lens thickness (LT), and Corneal Diameter (CD) were evaluated. The mean age was 69 ± 10 years (44-99 years). Mean AL, Km, and ACD were 23.87 ± 1.55 mm (19.8-31.92 mm), 43.91 ± 1.71 D (40.61-51.14 D), and 3.25 ± 0.44 mm (2.04-5.28 mm), respectively. The mean LT was 4.32 ± 0.49 mm (2.73-5.77 mm) and the mean CD was 12.02 ± 0.46 mm (10.50-14.15 mm). The mean corneal astigmatism was 1.08 ± 0.84 D (0.00-7.58 D) and 43.5% of eyes had astigmatism ≥ 1.00 D. Male patients had longer AL and ACDs (p < .001) and flatter corneas (p < .001). In regression models considering age, gender, Km, ACD, LT, and CD, a longer AL was associated with being male and having higher ACD, LT and CD. These data represent normative biometric values for the Portuguese population. The greatest predictor of ocular biometrics was gender. There was no significant correlation between age and AL, ACD, or Km. These results may be relevant in the evaluation of refractive error and in the calculation of intraocular lens power.

  6. Small-airway obstruction and emphysema in chronic obstructive pulmonary disease.

    PubMed

    McDonough, John E; Yuan, Ren; Suzuki, Masaru; Seyednejad, Nazgol; Elliott, W Mark; Sanchez, Pablo G; Wright, Alexander C; Gefter, Warren B; Litzky, Leslie; Coxson, Harvey O; Paré, Peter D; Sin, Don D; Pierce, Richard A; Woods, Jason C; McWilliams, Annette M; Mayo, John R; Lam, Stephen C; Cooper, Joel D; Hogg, James C

    2011-10-27

    The major sites of obstruction in chronic obstructive pulmonary disease (COPD) are small airways (<2 mm in diameter). We wanted to determine whether there was a relationship between small-airway obstruction and emphysematous destruction in COPD. We used multidetector computed tomography (CT) to compare the number of airways measuring 2.0 to 2.5 mm in 78 patients who had various stages of COPD, as judged by scoring on the Global Initiative for Chronic Obstructive Lung Disease (GOLD) scale, in isolated lungs removed from patients with COPD who underwent lung transplantation, and in donor (control) lungs. MicroCT was used to measure the extent of emphysema (mean linear intercept), the number of terminal bronchioles per milliliter of lung volume, and the minimum diameters and cross-sectional areas of terminal bronchioles. On multidetector CT, in samples from patients with COPD, as compared with control samples, the number of airways measuring 2.0 to 2.5 mm in diameter was reduced in patients with GOLD stage 1 disease (P=0.001), GOLD stage 2 disease (P=0.02), and GOLD stage 3 or 4 disease (P<0.001). MicroCT of isolated samples of lungs removed from patients with GOLD stage 4 disease showed a reduction of 81 to 99.7% in the total cross-sectional area of terminal bronchioles and a reduction of 72 to 89% in the number of terminal bronchioles (P<0.001). A comparison of the number of terminal bronchioles and dimensions at different levels of emphysematous destruction (i.e., an increasing value for the mean linear intercept) showed that the narrowing and loss of terminal bronchioles preceded emphysematous destruction in COPD (P<0.001). These results show that narrowing and disappearance of small conducting airways before the onset of emphysematous destruction can explain the increased peripheral airway resistance reported in COPD. (Funded by the National Heart, Lung, and Blood Institute and others.).

  7. Circulating levels of p,p'-DDE are related to prevalent hypertension in the elderly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lind, P. Monica, E-mail: monica.lind@medsci.uu.se; Penell, Johanna; Salihovic, Samira

    Background: Polychlorinated biphenyls (PCBs) and dioxin given to experimental animals increase the blood pressure. We therefore investigated if circulating levels of persistent organic pollutants (POPs) were related to hypertension in a population-based sample of men and women. Methods: One thousand and sixteen subjects aged 70 years were investigated in the Prospective Investigation of the Vasculature in Uppsala Seniors (PIVUS) study. Twenty-three POPs were analyzed using high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS). Hypertension was defined as a systolic blood pressure ≥140 mmHg or a diastolic blood pressure ≥90 mmHg, and/or use of antihypertensive medication. Results: Seven hundred and thirty-two subjects (72%)more » showed hypertension. When the POPs were treated as continuous variables and adjusted for gender only, two PCBs with a low number of chlorine atoms (PCB 105 and 118) were related to prevalent hypertension. Also the OC pesticide p,p'-DDE was related to hypertension. The strongest of these associations was seen for p,p'-DDE (OR 1.35 for a 1 SD change, 95% CI 1.17–1.56, p<0.0001). Following further adjustment also for BMI, smoking status, education level and exercise habits, only p,p'-DDE was still significantly related to hypertension (OR 1.23 for a 1 SD change, 95% CI 1.06–1.43, p=0.006). Conclusion: In this cross-sectional analysis of an elderly population, high levels of circulating levels of p,p'-DDE were associated with prevalent hypertension, further strengthening the experimental findings that POPs might influence blood pressure. - Highlights: • We evaluated the relation between POPs and hypertension. • Cross sectional data from a cohort of elderly men and women were analyzed. • The main exposure was circulating levels of 23 different POPs. • Hypertension was defined as ≥140/90 mmHg and/or antihypertensive treatment. • High levels of p,p'-DDE were associated with prevalent hypertension.« less

  8. Vascular and metabolic comorbidities in open-angle glaucoma with low- and high-teen intraocular pressure: a cross-sectional study from South Korea.

    PubMed

    Lee, Si Hyung; Kim, Gyu Ah; Lee, Wonseok; Bae, Hyoung Won; Seong, Gong Je; Kim, Chan Yun

    2017-11-01

    To assess the associations between vascular and metabolic comorbidities and the prevalence of open-angle glaucoma (OAG) with low-teen and high-teen intraocular pressure (IOP) in Korea. Cross-sectional data from the Korean National Health and Nutrition Examination Survey from 2008 to 2012 were analysed. Participants diagnosed with OAG with normal IOP were further classified into low-teen IOP (IOP ≤ 15 mmHg) and high-teen IOP (15 mmHg < IOP ≤ 21 mmHg) groups. Using multiple logistic regression analyses, the associations between vascular and metabolic comorbidities and the prevalence of glaucoma were investigated for the low- and high-teen IOP groups. The prevalences of hypertension, hyperlipidemia, ischaemic heart disease, stroke and metabolic syndrome were significantly higher among subjects with low-teen OAG compared with normal subjects, while only the prevalences of hypertension and stroke were higher among subjects with high-teen OAG compared with normal subjects. In multivariate logistic regression models adjusted for confounding factors, low-teen OAG was significantly associated with hypertension (OR, 1.68; 95% CI, 1.30-2.18), hyperlipidemia (OR, 1.49; 95% CI, 1.07-2.08), ischaemic heart disease (OR, 1.83; 95% CI, 1.07-3.11), stroke (OR, 1.91; 95% CI, 1.12-3.25) and metabolic syndrome (OR, 1.46; 95% CI, 1.12-1.90). High-teen OAG was only associated with stroke (OR, 2.58; 95% CI, 1.20-5.53). Various vascular and metabolic comorbidities were significantly associated with low-teen OAG, but not with high-teen OAG. These data support the hypothesis that vascular factors play a more significant role in the pathogenesis of OAG with low-teen baseline IOP. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  9. 6D.03: FLOW-MEDIATED DILATATION (FMD) AND ENDOTHELIUM-INDEPENDENT DILATATION (EID) IN PATIENTS WITH MULTIFOCAL FIBROMUSCULAR DYSPLASIA: A CROSS-SECTIONAL STUDY.

    PubMed

    Khettab, H; Lorthior, A; Niarra, R; Chambon, Y; Jeunemaitre, X; Plouin, P F; Laurent, S; Boutouyrie, P; Azizi, M

    2015-06-01

    Fibromuscular dysplasia (FD) is a rare idiopathic, segmental, non-atherosclerotic non-inflammatory vascular disease. We previously showed that FD is a general arterial disease with focal exacerbation of the trait. However, whether endothelial dysfunction may be involved in the pathophysiology of FD is unclear. In a cross sectional study, we compared the endothelial function between 50 patients with multifocal FD of renal/carotid arteries confirmed by CT-angiography, 50 essential hypertensive (EH) patients matched for age, sex, ethnicity and BP and 50 healthy subjects (HS) matched for age, sex and ethnicity. Exclusion criteria were: tobacco consumption, hypercholesterolemia, diabetes, aspirin or statin treatment. Brachial artery (BA) FMD after release of hand ischemia and glyceryl trinitrate (GTN)-induced EID was measured using a high-resolution radiofrequency-based echotracking system blind to the diagnosis. FD, EH and HS were well matched (52yrs, 85% women, 80% caucasian). SBP was higher in FD (125 ± 15mmHg) and EH (121 ± 12mmHg) than EH (113 ± 10mmHg) despite antihypertensive treatments. BA external diameter was significantly lower in FD than in both HS and EH before, during and after hand ischemia and after GTN. BA intima media thickness (IMT), internal diameter did not differ between the 3 groups. FMD (%) or EID (%) did not significantly differ between the 3 groups. BA flow velocity did not significantly differ in any experimental condition.(Figure is included in full-text article.) : In conclusion, despite showing similar acute vasodilatory responses to flow and GTN, FD patients differed from EH and HS in terms of arterial morphology with smaller BA diameter associated with similar IMT. This paradoxical remodeling may suggest a chronic defect in the endothelium-dependent pathways involved in arterial remodeling in FD patients.

  10. Association of atopy and tentative diagnosis of skin cancer - results from occupational skin cancer screenings.

    PubMed

    Schäfer, I; Mohr, P; Zander, N; Fölster-Holst, R; Augustin, M

    2017-12-01

    The relationship between atopic conditions and carcinoma of the skin has been described inconsistently. Population-based data providing information on atopic diseases as well as on skin cancer are sparse. To determine the correlation between atopy and prevalence of precanceroses, non-melanoma skin cancer and malignant melanoma (MM), while taking into account known risk factors for skin cancer. Data from occupational skin cancer screenings were analysed in a cross-sectional study. Dermatologists performed whole body examinations and collected medical histories. Subjects comprised all employees (16-70 years) examined from 2006 to 2014. 'Atopy' was defined by clinical screening diagnosis and/or by participant-reported, pre-existing atopic dermatitis, allergic asthma or other specified allergies confirmed by a physician. Tentative screening diagnoses of skin cancer related to actinic keratosis, basal cell carcinoma and malignant melanoma. The study cohort comprised 90 265 employees (mean age 43 ± 11 years, 58.5% male), 30.7% of whom were ever diagnosed with an atopic disease. Persons with atopic conditions recorded in their medical history and at the time of screening had a significantly lower prevalence of actinic keratosis (AK), basal cell carcinoma (BCC) and MM. After controlling for age, sex and relevant risk factors (skin type, childhood sun burns), atopy remained significantly protective against BCC (OR 0.77) and MM (OR 0.53). Design limitations of the study include that all findings of skin cancer were based on clinical examination only and must therefore be considered tentative diagnoses. Furthermore, owing to the cross-sectional study design, causal pathways cannot be proven. However, analyses of data from such a large and general population-based cohort afford valuable insights into the relationship between atopic diseases and skin cancer. They provide the grounds for prospective cohort studies to evaluate and dissect the underlying mechanism. © 2017 European Academy of Dermatology and Venereology.

  11. Physical inactivity is associated with narrower lumbar intervertebral discs, high fat content of paraspinal muscles and low back pain and disability.

    PubMed

    Teichtahl, Andrew J; Urquhart, Donna M; Wang, Yuanyuan; Wluka, Anita E; O'Sullivan, Richard; Jones, Graeme; Cicuttini, Flavia M

    2015-05-07

    Although physical inactivity has been associated with numerous chronic musculoskeletal complaints, few studies have examined its associations with spinal structures. Moreover, previously reported associations between physical activity and low back pain are conflicting. This study examined the associations between physical inactivity and intervertebral disc height, paraspinal fat content and low back pain and disability. Seventy-two community-based volunteers not selected for low back pain underwent magnetic resonance imaging (MRI) of their lumbosacral spine (L1 to S1) between 2011 and 2012. Physical activity was assessed between 2005 and 2008 by questionnaire, while low back pain and disability were assessed by the Chronic Pain Grade Scale at the time of MRI. Intervertebral disc height and cross-sectional area and fat content of multifidus and erector spinae were assessed from MRI. Lower physical activity levels were associated with a more narrow average intervertebral disc height (β -0.63 mm, 95% confidence interval (CI) -1.17 mm to -0.08 mm, P = 0.026) after adjusting for age, gender and body mass index (BMI). There were no significant associations between physical activity levels and the cross-sectional area of multifidus or erector spinae. Lower levels of physical activity were associated with an increased risk of high fat content in multifidus (odds ratio (OR) 2.7, 95% CI 1.1 to 6.7, P = 0.04) and high-intensity pain/disability (OR = 5.0, 95% CI 1.5 to 16.4, P = 0.008) after adjustment for age, gender and BMI. Physical inactivity is associated with narrower intervertebral discs, high fat content of the multifidus and high-intensity low back pain and disability in a dose-dependent manner among community-based adults. Longitudinal studies will help to determine the cause and effect nature of these associations.

  12. A comparison of the wear of cross-linked polyethylene against itself with the wear of ultra-high molecular weight polyethylene against itself.

    PubMed

    Joyce, T J; Unsworth, A

    1996-01-01

    Wear tests were carried out on reciprocating pin-on-plate machines which had pins loaded at 10 N and 40 N. The materials tested were irradiated cross-linked polyethylene sliding against itself, irradiated ultra-high molecular weight polyethylene sliding against itself and non-irradiated ultra-high molecular weight polyethylene sliding against itself. After 153.5 km of sliding, the non-irradiated ultra-high molecular weight polyethylene plates and pins showed mean wear factors under 10 N loads, or a nominal contact stress of 0.51 MPa, of 84.0 x 10(-6) mm3/N m for the plates and 81.3 x 10(-6) mm3/N m for the pins. Under 40 N loads, or a nominal contact stress of 2.04 MPa, the non-irradiated ultra-high molecular weight polyethylene pins sheared at 22.3 km. At the last measurement point prior to this failure, 19.1 km, wear factors of 158 x 10(-6) mm3/N m for the plates and 85.0 x 10(-6) mm3/N m for the pins had been measured. After 152.8 km. the irradiated ultra-high molecular weight polyethylene plates and pins showed mean wear factors under 10 N loads of 59.8 x 10(-6) mm3/N m for the plates and 31.1 x 10(-6) mm3/N m for the pins. In contrast, after 150.2 km, a mean wear factor of 0.72 x 10(-6) mm3/N m was found for the irradiated cross-linked polyethylene plates compared with 0.053 x 10(-6) mm3/N m for the irradiated cross-linked polyethylene pins.

  13. Performance of thin long scintillator strips of GSO:Ce, LGSO:Ce and LuAG:Pr for low energy γ-rays

    NASA Astrophysics Data System (ADS)

    Kobayashi, Masaaki; Aogaki, Souichiro; Takeutchi, Fujio; Tamagawa, Yoichi; Usuki, Yoshiyuki

    2012-11-01

    Interest in fibers or strips of single crystalline scintillators is increasing for their possible applications in fine-segmented particle detectors for particle physics experiments as well as γ-ray detectors for medical diagnoses. We compared 2×2×100 mm3 strips of Gd2SiO5(GSO):Ce, Lu1.9Gd0.1SiO5 (LGSO):Ce, and Lu3Al5O12(LuAG):Pr single crystals for 0.511 MeV γ-rays with respect to the effective light attenuation length λa, light yield LY, FWHM energy resolution ΔE/E and rms position resolution σ(z) of the injection position z along the length. The obtained result was (λa, LY, ΔE/E, σ(z))=(128 mm, 380 phe/MeV, 17.7%, 8.7 mm) in GSO:Ce, (509 mm, 1760 phe/MeV, 12.2%, 10.9 mm) in LGSO:Ce, and (171 mm, 690 phe/MeV, 15.0%, 8.9 mm) in LuAG:Pr. The z position was obtained independently from the pulse height ratio as well as the timing difference between both ends of the strip. The latter method gave comparable or even smaller σ(z) than the former only in LGSO:Ce having both large LY and fast rise time. The λa in the 100 mm long GSO:Ce strip was found to be twice as large as that in the 200 mm long one [1] with the same cross-section. To obtain good ΔE/E and σ(z), large light yield, fast rise time, and moderately large attenuation length are important for the scintillators.

  14. Retrodeformable cross sections and Oak Ridge fault, Ventura basin, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yeats, R.S.; Huftile, G.F.

    1988-03-01

    A retrodeformable (balanced) cross section is constructed such that stratified rocks are restored to their undeformed state without loss or gain of bed length or bed thickness. Ductile strata may be area-balanced if original thickness is known. Near Ventura, folds in Pliocene-Pleistocene turbidites and Miocene-early Pliocene shales (Rincon, Monterey, Sisquoc) overlie an unfolded competent Paleogene sequence. The basal decollement of the foldbelt is in the ductile Rincon Formation (lower Miocene). The overlying Sulphur Mountain, Ventura Avenue, San Miguelito, and Rincon anticlines are fault-propagation folds developing from south-dipping, largely late Quaternary frontal ramp thrusts (Sisar-Big Canyon-Lion fault set, Barnard fault set,more » padre Juan fault, and C-3 fault, respectively) that rise from the decollement. Cross-section balancing shows that the overlying fold-thrust belt has shortened 2.5-6 km more than subjacent Paleogene competent strata. This excess bed length is taken up in the Paleogene sequence on the Oak Ridge fault as a ramp from the brittle-plastic transition zone through the upper crust. This implies that the basal decollement is the frontal active thrust of the Oak Ridge fault. The decollement dies out southeast of a line between Timber Canyon oil field and the west end of Oak Ridge, possibly because of decreased ductility in the Miocene decollement sequence due to appearance of sandstone interbeds. Farther southeast, late Quaternary displacement concentrated on the Oak Ridge fault itself at rates greater than 10 mm/year.« less

  15. Distribution of tissue characteristics of coronary plaques evaluated by integrated backscatter intravascular ultrasound: Differences between the inner and outer vessel curvature.

    PubMed

    Sato, Hironobu; Kawasaki, Masanori; Morita, Norihiko; Fujiwara, Hisayoshi; Minatoguchi, Shinya

    2015-12-01

    The purpose of the present study was to evaluate the tissue characteristics of plaques with moderate or mild stenosis in the inner and outer curvature of the left anterior descending artery (LAD) using integrated backscatter intravascular ultrasound. We evaluated 66 plaques with moderate stenosis (plaque burden >50% but ≤75%) and 49 plaques with mild stenosis (plaque burden >30% but ≤50%) in 66 patients undergoing percutaneous intervention to the LAD. All plaques were >10mm away from any side branch or previously implanted stents. We divided vessel cross-sections into four quadrants (inner curvature, outer curvature, clockwise lateral side, and counterclockwise lateral side) using the septal branch as a landmark for the inner curvature. We averaged relative lipid area, relative fibrous area, and relative calcified area in minimal lumen area (MLA), three cross-sections proximal to the site of MLA, and three cross-sections distal to the site of MLA. In plaques with moderate stenosis, the relative lipid area in the inner curvature was significantly greater than in the outer curvature and lateral sides, whereas there was no significant difference in plaques with mild stenosis. The present study provides new findings that lipid pool is clustered in the inner curvature and fibrous tissue is clustered in the outer curvature of plaques with moderate stenosis in non-branching LAD lesions. Copyright © 2015 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  16. Effects of anchoring and arc structure on the control authority of a rail plasma actuator

    NASA Astrophysics Data System (ADS)

    Choi, Young-Joon; Gray, Miles; Sirohi, Jayant; Raja, Laxminarayan L.

    2017-09-01

    Experiments were conducted on a rail plasma actuator (RailPAc) with different electrode cross sections (rails or rods) to assess methods to improve the actuation authority, defined as the impulse generated for a given electrical input. The arc was characterized with electrical measurements and high-speed images, while impulse measurements quantified the actuation authority. A RailPAc power supply capable of delivering  ∼1 kA of current at  ∼100 V was connected to rod electrodes (free-floating with circular cross-section) and rail electrodes (flush-mounted in a flat plate with rectangular cross-section). High-speed images show that the rail electrodes cause the arc to anchor itself to the anode electrode and transit in discrete jumps, while rod electrodes permit the arc to transit smoothly without anchoring. The impulse measurements reveal that the anchoring reduces the actuation authority by  ∼21% compared to a smooth transit, and the effect of anchoring can be suppressed by reducing the gap between the rails to 2 mm. The study further demonstrates that if a smooth transit is achieved, the control authority can be increased with a larger gap and larger arc current. In conclusion, the actuation authority of a RailPAc can be maximized by carefully choosing a gap width that prevents anchoring. Further study is warranted to increase the RailPAc actuation authority by introducing multiple turns of wires beneath the RailPAc to augment the induced magnetic field.

  17. Tomographic sensing and localization of fluorescently labeled circulating cells in mice in vivo

    NASA Astrophysics Data System (ADS)

    Zettergren, Eric; Swamy, Tushar; Runnels, Judith; Lin, Charles P.; Niedre, Mark

    2012-07-01

    Sensing and enumeration of specific types of circulating cells in small animals is an important problem in many areas of biomedical research. Microscopy-based fluorescence in vivo flow cytometry methods have been developed previously, but these are typically limited to sampling of very small blood volumes, so that very rare circulating cells may escape detection. Recently, we described the development of a ‘diffuse fluorescence flow cytometer’ (DFFC) that allows sampling of much larger blood vessels and therefore circulating blood volumes in the hindlimb, forelimb or tail of a mouse. In this work, we extend this concept by developing and validating a method to tomographically localize circulating fluorescently labeled cells in the cross section of a tissue simulating optical flow phantom and mouse limb. This was achieved using two modulated light sources and an array of six fiber-coupled detectors that allowed rapid, high-sensitivity acquisition of full tomographic data sets at 10 Hz. These were reconstructed into two-dimensional cross-sectional images using Monte Carlo models of light propagation and the randomized algebraic reconstruction technique. We were able to obtain continuous images of moving cells in the sample cross section with 0.5 mm accuracy or better. We first demonstrated this concept in limb-mimicking optical flow photons with up to four flow channels, and then in the tails of mice with fluorescently labeled multiple myeloma cells. This approach increases the overall diagnostic utility of our DFFC instrument.

  18. Minimum five-year follow-up wear measurement of longevity highly cross-linked polyethylene cup against cobalt-chromium or zirconia heads.

    PubMed

    Nakahara, Ichiro; Nakamura, Nobuo; Nishii, Takashi; Miki, Hidenobu; Sakai, Takashi; Sugano, Nobuhiko

    2010-12-01

    We investigated the efficacy of combining highly cross-linked polyethylene with ceramic heads on further reduction in polyethylene wear compared with the combination with cobalt-chromium heads via PolyWare computer-assisted method. A prospective cohort study was performed on 102 cementless total hip arthroplasties using Longevity (Zimmer, Warsaw, Ind) highly cross-linked polyethylene liners. Either 26-mm zirconia heads or 26-mm cobalt-chromium heads were randomly used in 51 hips each. At a mean follow-up of 6.7 years, no significant differences were identified between the groups for total penetration rate and steady-state wear rate. Osteolysis was not observed in any hips in either group. In conclusion, no advantage was seen for the 26-mm zirconia head compared with the 26-mm cobalt-chromium head in this period. Copyright © 2010 Elsevier Inc. All rights reserved.

  19. Static resistivity image of a cubic saline phantom in magnetic resonance electrical impedance tomography (MREIT).

    PubMed

    Lee, Byung Il; Oh, Suk Hoon; Woo, Eung Je; Lee, Soo Yeol; Cho, Min Hyeong; Kwon, Ohin; Seo, Jin Keun; Baek, Woon Sik

    2003-05-01

    In magnetic resonance electrical impedance tomography (MREIT) we inject currents through electrodes placed on the surface of a subject and try to reconstruct cross-sectional resistivity (or conductivity) images using internal magnetic flux density as well as boundary voltage measurements. In this paper we present a static resistivity image of a cubic saline phantom (50 x 50 x 50 mm3) containing a cylindrical sausage object with an average resistivity value of 123.7 ohms cm. Our current MREIT system is based on an experimental 0.3 T MRI scanner and a current injection apparatus. We captured MR phase images of the phantom while injecting currents of 28 mA through two pairs of surface electrodes. We computed current density images from magnetic flux density images that are proportional to the MR phase images. From the current density images and boundary voltage data we reconstructed a cross-sectional resistivity image within a central region of 38.5 x 38.5 mm2 at the middle of the phantom using the J-substitution algorithm. The spatial resolution of the reconstructed image was 64 x 64 and the reconstructed average resistivity of the sausage was 117.7 ohms cm. Even though the error in the reconstructed average resistivity value was small, the relative L2-error of the reconstructed image was 25.5% due to the noise in measured MR phase images. We expect improvements in the accuracy by utilizing an MRI scanner with higher SNR and increasing the size of voxels scarifying the spatial resolution.

  20. A cross-sectional survey of blood pressure of a coastal city's resident victims of the 2011 Tohoku tsunami.

    PubMed

    Murakami, Hitoshi; Akashi, Hidechika; Noda, Shinichiro; Mizoue, Tetsuya; Okazaki, Osamu; Ouchi, Yoshiko; Okaji, Yuki; Kajiwara, Chieko; Miyoshi, Chiaki

    2013-06-01

    Blood pressure (BP) increase as a reaction to major disasters has been well documented; however, the impact has been underdocumented for tsunamis. This study aimed to confirm whether different levels of flooding/inundation and other damage caused by the 2011 Tohoku (northeast Japan) tsunami were associated with BP among resident victims in Higashi-Matsushima, Miyagi. Cross-sectional household screening was conducted 7-19 weeks after the disaster in administrative areas totally or partially flooded by the tsunami. Systolic and diastolic BP (SBP/DBP) were measured in 4,311 residents. There was a degree-dependent association between SBP/DBP and flooding height above sea level among victims not on antihypertensive medication (P < 0.01 for both). Disruption of the gas supply was also significantly associated with SBP/DBP (P < 0.01 for both). Among individuals on antihypertensive medication, the discontinuation of medication was associated with SBP/DBP (P < 0.01 for both). After adjusting for confounding and multiplicity, a matched case-control analysis did not identify any significant associations between the tsunami or lifeline indicators and high BP (SBP ≥160mm Hg or DBP ≥100mm Hg). This study suggests that after a major tsunami, resident victims in areas highly inundated by flood waters and those with disrupted gas supply are more likely to have higher BP and thus might warrant getting BP screening earlier than other residents. Those with hypertension should be given assistance to resume or commence antihypertensive medication as soon as possible to reduce the risk of cardiovascular morbidity and mortality.

  1. Assessment of the role of cross section on fatigue resistance of rotary files when used in reciprocation.

    PubMed

    Sekar, Vadhana; Kumar, Ranjith; Nandini, Suresh; Ballal, Suma; Velmurugan, Natanasabapathy

    2016-01-01

    The purpose of this study was to assess the role of cross section on cyclic fatigue resistance of One Shape, Revo-S SU, and Mtwo rotary files in continuous rotation and reciprocating motion in dynamic testing model. A total of 90 new rotary One Shape, Revo-S SU, and Mtwo files (ISO size 25, taper 0.06, length 25 mm) were subjected to continuous rotation or reciprocating motion. A cyclic fatigue testing device was fabricated with 60° angle of curvature and 5 mm radius. The dynamic testing of these files was performed using an electric motor which permitted the reproduction of pecking motion. All instruments were rotated or reciprocated until fracture occurred. The time taken for each instrument to fracture was recorded. All the fractured files were analyzed under a scanning electron microscope (SEM) to detect the mode of fracture. Statistical analysis was performed using one-way ANOVA, followed by Tukey's honestly significant difference post hoc test. The time taken for instruments in reciprocating motion to fail under cyclic loading was significantly longer when compared with groups in continuous rotary motion. There was a statistically significant difference between Mtwo rotary and the other two groups in both continuous and reciprocating motion. One Shape rotary files recorded significantly longer duration to fracture resistance when compared with Revo-S SU files in both continuous and reciprocating motion. SEM observations showed that the instruments of all groups had undergone a ductile mode of fracture. Reciprocating motion improved the cyclic fatigue resistance of all tested groups.

  2. Assessment of the role of cross section on fatigue resistance of rotary files when used in reciprocation

    PubMed Central

    Sekar, Vadhana; Kumar, Ranjith; Nandini, Suresh; Ballal, Suma; Velmurugan, Natanasabapathy

    2016-01-01

    Objective: The purpose of this study was to assess the role of cross section on cyclic fatigue resistance of One Shape, Revo-S SU, and Mtwo rotary files in continuous rotation and reciprocating motion in dynamic testing model. Materials and Methods: A total of 90 new rotary One Shape, Revo-S SU, and Mtwo files (ISO size 25, taper 0.06, length 25 mm) were subjected to continuous rotation or reciprocating motion. A cyclic fatigue testing device was fabricated with 60° angle of curvature and 5 mm radius. The dynamic testing of these files was performed using an electric motor which permitted the reproduction of pecking motion. All instruments were rotated or reciprocated until fracture occurred. The time taken for each instrument to fracture was recorded. All the fractured files were analyzed under a scanning electron microscope (SEM) to detect the mode of fracture. Statistical analysis was performed using one-way ANOVA, followed by Tukey's honestly significant difference post hoc test. Results: The time taken for instruments in reciprocating motion to fail under cyclic loading was significantly longer when compared with groups in continuous rotary motion. There was a statistically significant difference between Mtwo rotary and the other two groups in both continuous and reciprocating motion. One Shape rotary files recorded significantly longer duration to fracture resistance when compared with Revo-S SU files in both continuous and reciprocating motion. SEM observations showed that the instruments of all groups had undergone a ductile mode of fracture. Conclusion: Reciprocating motion improved the cyclic fatigue resistance of all tested groups. PMID:28042272

  3. Choriocapillaris and Choroidal Microvasculature Imaging with Ultrahigh Speed OCT Angiography

    PubMed Central

    Choi, WooJhon; Mohler, Kathrin J.; Potsaid, Benjamin; Lu, Chen D.; Liu, Jonathan J.; Jayaraman, Vijaysekhar; Cable, Alex E.; Duker, Jay S.; Huber, Robert; Fujimoto, James G.

    2013-01-01

    We demonstrate in vivo choriocapillaris and choroidal microvasculature imaging in normal human subjects using optical coherence tomography (OCT). An ultrahigh speed swept source OCT prototype at 1060 nm wavelengths with a 400 kHz A-scan rate is developed for three-dimensional ultrahigh speed imaging of the posterior eye. OCT angiography is used to image three-dimensional vascular structure without the need for exogenous fluorophores by detecting erythrocyte motion contrast between OCT intensity cross-sectional images acquired rapidly and repeatedly from the same location on the retina. En face OCT angiograms of the choriocapillaris and choroidal vasculature are visualized by acquiring cross-sectional OCT angiograms volumetrically via raster scanning and segmenting the three-dimensional angiographic data at multiple depths below the retinal pigment epithelium (RPE). Fine microvasculature of the choriocapillaris, as well as tightly packed networks of feeding arterioles and draining venules, can be visualized at different en face depths. Panoramic ultra-wide field stitched OCT angiograms of the choriocapillaris spanning ∼32 mm on the retina show distinct vascular structures at different fundus locations. Isolated smaller fields at the central fovea and ∼6 mm nasal to the fovea at the depths of the choriocapillaris and Sattler's layer show vasculature structures consistent with established architectural morphology from histological and electron micrograph corrosion casting studies. Choriocapillaris imaging was performed in eight healthy volunteers with OCT angiograms successfully acquired from all subjects. These results demonstrate the feasibility of ultrahigh speed OCT for in vivo dye-free choriocapillaris and choroidal vasculature imaging, in addition to conventional structural imaging. PMID:24349078

  4. Choriocapillaris and choroidal microvasculature imaging with ultrahigh speed OCT angiography.

    PubMed

    Choi, WooJhon; Mohler, Kathrin J; Potsaid, Benjamin; Lu, Chen D; Liu, Jonathan J; Jayaraman, Vijaysekhar; Cable, Alex E; Duker, Jay S; Huber, Robert; Fujimoto, James G

    2013-01-01

    We demonstrate in vivo choriocapillaris and choroidal microvasculature imaging in normal human subjects using optical coherence tomography (OCT). An ultrahigh speed swept source OCT prototype at 1060 nm wavelengths with a 400 kHz A-scan rate is developed for three-dimensional ultrahigh speed imaging of the posterior eye. OCT angiography is used to image three-dimensional vascular structure without the need for exogenous fluorophores by detecting erythrocyte motion contrast between OCT intensity cross-sectional images acquired rapidly and repeatedly from the same location on the retina. En face OCT angiograms of the choriocapillaris and choroidal vasculature are visualized by acquiring cross-sectional OCT angiograms volumetrically via raster scanning and segmenting the three-dimensional angiographic data at multiple depths below the retinal pigment epithelium (RPE). Fine microvasculature of the choriocapillaris, as well as tightly packed networks of feeding arterioles and draining venules, can be visualized at different en face depths. Panoramic ultra-wide field stitched OCT angiograms of the choriocapillaris spanning ∼32 mm on the retina show distinct vascular structures at different fundus locations. Isolated smaller fields at the central fovea and ∼6 mm nasal to the fovea at the depths of the choriocapillaris and Sattler's layer show vasculature structures consistent with established architectural morphology from histological and electron micrograph corrosion casting studies. Choriocapillaris imaging was performed in eight healthy volunteers with OCT angiograms successfully acquired from all subjects. These results demonstrate the feasibility of ultrahigh speed OCT for in vivo dye-free choriocapillaris and choroidal vasculature imaging, in addition to conventional structural imaging.

  5. The Relationship between Metabolic Syndrome, Its Components, and Dry Eye: A Cross-Sectional Study.

    PubMed

    Erdur, Sevil Karaman; Aydin, Rukiye; Ozsutcu, Mustafa; Olmuscelik, Oktay; Eliacik, Mustafa; Demirci, Goktug; Kocabora, Mehmet Selim

    2017-08-01

    The aim of this study was to evaluate tear osmolarity and tear film function and ocular surface changes in patients with metabolic syndrome. 108 eyes of 64 patients with metabolic syndrome (group 1) and 110 eyes of 55 healthy individuals (group 2) were included in this cross-sectional study. All participants were evaluated using the Ocular Surface Disease Index (OSDI) questionnaire, Schirmer I test, tear film break-up time (TBUT), and tear osmolarity. Main outcome measures were Ocular Surface Disease Index (OSDI) questionnaire, Schirmer I test, tear film break-up time (TBUT), and tear osmolarity values. Tear osmolarity values and OSDI scores were significantly higher in group 1 (314.4 ± 19.1 mOsm and 38.9 ± 1.1, respectively) compared with group 2 (295 ± 14.3 mOsm and 18.69 ± 17.2, respectively) (p = 0.01 for both). The Schirmer test values and TBUT in group 1 (10 ± 3.7 mm and 14.8 ± 3.6 sec, respectively) were significantly lower compared with group 2 (16.8 ± 2.6 mm and 18.1 ± 0.5 sec, respectively) (p < 0.001 for both). There was significant correlation between tear osmolarity versus waist circumference and fasting blood glucose in the study group (r = 0.364, p = 0.04; and r = 0.542, p ≤ 0.001, respectively). This study showed that metabolic syndrome can influence tear osmolarity and tear film function. Patients with metabolic syndrome showed tear hyperosmolarity and tear film dysfunction.

  6. A PILOT STUDY OF DIAGNOSTIC NEUROMUSCULAR ULTRASOUND IN BELL'S PALSY

    PubMed Central

    TAWFIK, EMAN A.; WALKER, FRANCIS O.; CARTWRIGHT, MICHAEL S.

    2015-01-01

    Background and purpose Neuromuscular ultrasound of the cranial nerves is an emerging field which may help in the assessment of cranial neuropathies. The aim of this study was to evaluate the role of neuromuscular ultrasound in Bell's palsy. A second objective was to assess the possibility of any associated vagus nerve abnormality. Methods Twenty healthy controls and 12 Bell's palsy patients were recruited. The bilateral facial nerves, vagus nerves, and frontalis muscles were scanned using an 18 MHz linear array transducer. Facial nerve diameter, vagus nerve cross-sectional area, and frontalis thickness were measured. Results Mean facial nerve diameter was 0.8 ± 0.2 mm in controls and 1.1 ± 0.3 mm in patients group. The facial nerve diameter was significantly larger in patients than controls (p = 0.006, 95% CI for the difference between groups of 0.12-0.48), with a significant side-to-side difference in patients as well (p = 0.004, 95% CI for side-to-side difference of 0.08-0.52). ROC curve analysis of the absolute facial nerve diameter revealed a sensitivity of 75 % and a specificity of 70 %. No significant differences in vagus nerve cross-sectional area or frontalis thickness were detected between patients and controls. Conclusions Ultrasound can detect facial nerve enlargement in Bell's palsy and may have a role in assessment, or follow-up, of Bell's palsy and other facial nerve disorders. The low sensitivity of the current technique precludes its routine use for diagnosis, however, this study demonstrates its validity and potential for future research. PMID:26076910

  7. Virtual and Experimental Visualization of Flows in Packed Beds of Spheres Simulating Porous Media Flows

    NASA Technical Reports Server (NTRS)

    Hendricks, R. C.; Athavale, M. M.; Lattime, S. B.; Braun, M. J.

    1998-01-01

    A videotape presentation of flow in a packed bed of spheres is provided. The flow experiment consisted of three principal elements: (1) an oil tunnel 76.2 mm by 76.2 mm in cross section, (2) a packed bed of spheres in regular and irregular arrays, and (3) a flow characterization methodology, either (a) full flow field tracking (FFFT) or (b) computational fluid dynamic (CFD) simulation. The refraction indices of the oil and the test array of spheres were closely matched, and the flow was seeded with aluminum oxide particles. Planar laser light provided a two-dimensional projection of the flow field, and a traverse simulated a three-dimensional image of the entire flow field. Light focusing and reflection rendered the spheres black, permitting visualization of the planar circular interfaces in both the axial and transverse directions. Flows were observed near the wall-sphere interface and within the set of spheres. The CFD model required that a representative section of a packed bed be formed and gridded, enclosing and cutting six spheres so that symmetry conditions could be imposed at all cross-boundaries. Simulations had to be made with the flow direction at right angles to that used in the experiments, however, to take advantage of flow symmetry. Careful attention to detail was required for proper gridding. The flow field was three-dimensional and complex to describe, yet the most prominent finding was flow threads, as computed in the representative 'cube' of spheres with face symmetry and conclusively demonstrated experimentally herein. Random packing and bed voids tended to disrupt the laminar flow, creating vortices.

  8. Periodontal status in crack and cocaine addicted men: a cross-sectional study.

    PubMed

    Cury, Patricia Ramos; Oliveira, Maria Graças Alonso; Dos Santos, Jean Nunes

    2017-02-01

    This cross-sectional study evaluated the association between crack/cocaine addiction and periodontal disease in men. Periodontal examination (probing depth, clinical attachment level, bleeding on probing, and plaque index) and interviews were performed in 160 patients (≥18 years) from the Federal University of Bahia. Crack and cocaine dependence was defined according to the medical records and interviews of each patient; all drug addicted volunteers used both crack and cocaine. T test, Chi-square test, and logistic regression were used to assess the associations between destructive periodontal disease and crack/cocaine dependence (p ≤ 0.05). Probing depth was significantly greater in crack/cocaine addicted individuals (2.84 ± 0.76 mm) compared with non-addicted individuals (2.55 ± 0.73 mm, p = 0.04). After adjusting for covariates, periodontitis was not significantly associated with crack/cocaine addiction (OR = 2.31, 95 % CI = 0.82-6.46, p = 0.11), which was only associated with age ≥35 years (OR = 4.16, 95 % CI = 1.65-10.50, p = 0.003) and higher dental plaque index (OR = 6.46, 95 % CI = 1.95-21.42, p = 0.002). In conclusion, although probing depth was greater in crack/cocaine addicted individuals, destructive periodontal disease was not associated with crack and cocaine addiction in the present population. Destructive periodontal disease was associated with age and dental plaque. Further studies in a larger sample size are required to confirm the results.

  9. Development of a 30-kA cable-in-conduit conductor for pulsed poloidal coils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takashi, Y.; Dresner, L.; Kato, T.

    1983-05-01

    This paper describes design parameters of a 30-kA cable-in-conduit conductor (JF-30), and the test results of stability margin measured by using a triplex in a conduit. Cross sectional size of JF-30 is 35mm X 35 mm and 567 NbTi-Cu-CuNi strands are in a stainless steel conduit whose thickness is 2 mm. Void fraction is 33 % and the designed stability margin is 270 mJ/cc at 5 atm and 7 T. Stability test by a triplex showed a favorable margin, a few hundreds of mJ at 7 T even without helium flow. In addition, the stability was strongly increased when heliummore » flow up to 0.2 g/s was applied. At around 3 atm, the authors found that the stability margin was more than 2 J/cc which exceeded the present heater capacity. This resulted in an extension of current range, in which the sample is stable, up to 150 to 200 % when compared to the case without helium flow.« less

  10. An experimental study of the vortex wake at Mach number of 3

    NASA Astrophysics Data System (ADS)

    Shmakov, A. S.; Shevchenko, A. M.

    2017-10-01

    The results of experimental study of the flow in the wing wake at Mach number of 3 are presented. These experiments extends the data obtained in the same experimental setup at Mach numbers of 2.5 and 4 [1]. Experiments were carried out in supersonic wind tunnel T-325 of ITAM SB RAS. Rectangular half-wing with sharp edges with a chord length of 30 mm and semispan of 95 mm was used to generate vortex wake. Experimental data were obtained in two cross sections located 1.5 and 6 chord length downstream of the trailing edge at wing angle of attack of 10 degrees. Constant temperature hot-wire anemometer was used to measure disturbances in supersonic flow. Hot-wire aemometer was made of a tungsten wire with a diameter of 10 µm and length of 1.5 mm. Shlieren flow visualization were performed. As a result, the position and size of the vortex core in the wake of a rectangular wing were determined. For the first time mass flow distribution and its pulsations in the supersonic longitudinal vortex was measured at Mach number of 3.

  11. Design Guideline for New Generation of High-Temperature Guarded Hot Plate

    NASA Astrophysics Data System (ADS)

    Wu, J.; Hameury, J.; Failleau, G.; Blahut, A.; Vachova, T.; Strnad, R.; Krause, M.; Rafeld, E.; Hammerschmidt, U.

    2018-02-01

    This paper complements the existing measurement standards and literature for high-temperature guarded hot plates (HTGHPs) by addressing specific issues relating to thermal conductivity measurement of technical insulation at high temperatures. The examples given are focused on the designs of HTGHPs for measuring thin thermal insulation. The sensitivity studies have been carried out on major influencing factors that affect the thermal conductivity measurements using HTGHPs, e.g., the uncertainty of temperature measurements, plate flatness and center-guard gap design and imbalance. A new configuration of center-guard gap with triangular shape cross section has been optimized to obtain the same thermal resistance as a 2 mm wide gap with rectangular shape cross section that has been used in the HTGHPs at NPL and LNE. Recommendations have been made on the selections of heater plate materials, high-temperature high-emissivity coatings and miniature temperature sensors. For the first time, thermal stress analysis method has been applied to the field of HTGHPs, in order to estimate the effect of differential thermal expansion on the flatness of thin rigid specimens during thermal conductivity tests in a GHP.

  12. High-speed polarization sensitive optical frequency domain imaging with frequency multiplexing

    PubMed Central

    Yun, S.H.; Vakoc, B.J.; Shishkov, M.; Desjardins, A.E.; Park, B.H.; de Boer, J.F.; Tearney, G.J.; Bouma, B.E.

    2009-01-01

    Polarization sensitive optical coherence tomography (PS-OCT) provides a cross-sectional image of birefringence in biological samples that is complementary in many applications to the standard reflectance-based image. Recent ex vivo studies have demonstrated that birefringence mapping enables the characterization of collagen and smooth muscle concentration and distribution in vascular tissues. Instruments capable of applying these measurements percutaneously in vivo may provide new insights into coronary atherosclerosis and acute myocardial infarction. We have developed a polarization sensitive optical frequency domain imaging (PS-OFDI) system that enables high-speed intravascular birefringence imaging through a fiber-optic catheter. The novel design of this system utilizes frequency multiplexing to simultaneously measure reflectance of two incident polarization states, overcoming concerns regarding temporal variations of the catheter fiber birefringence and spatial variations in the birefringence of the sample. We demonstrate circular cross-sectional birefringence imaging of a human coronary artery ex vivo through a flexible fiber-optic catheter with an A-line rate of 62 kHz and a ranging depth of 6.2 mm. PMID:18542183

  13. Accuracy verification of magnetic resonance imaging (MRI) technology for lower-limb prosthetic research: utilising animal soft tissue specimen and common socket casting materials.

    PubMed

    Safari, Mohammad Reza; Rowe, Philip; Buis, Arjan

    2012-01-01

    Lower limb prosthetic socket shape and volume consistency can be quantified using MRI technology. Additionally, MRI images of the residual limb could be used as an input data for CAD-CAM technology and finite element studies. However, the accuracy of MRI when socket casting materials are used has to be defined. A number of six, 46 mm thick, cross-sections of an animal leg were used. Three specimens were wrapped with Plaster of Paris (POP) and the other three with commercially available silicone interface liner. Data was obtained by utilising MRI technology and then the segmented images compared to corresponding calliper measurement, photographic imaging, and water suspension techniques. The MRI measurement results were strongly correlated with actual diameter, surface area, and volume measurements. The results show that the selected scanning parameters and the semiautomatic segmentation method are adequate enough, considering the limit of clinical meaningful shape and volume fluctuation, for residual limb volume and the cross-sectional surface area measurements.

  14. A comparison of nickel-titanium rotary instruments manufactured using different methods and cross-sectional areas: ability to resist cyclic fatigue.

    PubMed

    Oh, So-Ram; Chang, Seok-Woo; Lee, Yoon; Gu, Yu; Son, Won-Jun; Lee, Woocheol; Baek, Seung-Ho; Bae, Kwang-Shik; Choi, Gi-Woon; Lim, Sang-Min; Kum, Kee-Yeon

    2010-04-01

    This study examined the effect of the manufacturing methods (ground, electropolished, and twisted) and the cross-sectional area (CSA) of nickel-titanium (NiTi) rotary instruments on their cyclic fatigue resistance. A total of 80 NiTi rotary instruments (ISO 25/.06 taper) from 4 brands (K3, ProFile, RaCe, and TF) were rotated in a simulated root canal with pecking motion until fracture. The number of cycles to failure (NCF) was calculated. The CSA at 3 mm from the tip of new instruments of each brand was calculated. The correlation between the CSA and NCF was evaluated. All fractured surfaces were analyzed using a scanning electron microscope to determine the fracture mode. The TF instruments were the most resistant to fatigue failure. The resistance to cyclic failure increased with decreasing CSA. All fractured surfaces showed the coexistence of ductile and brittle properties. The CSA had a significant effect on the fatigue resistance of NiTi rotary instruments. Copyright 2010 Mosby, Inc. All rights reserved.

  15. Accuracy Verification of Magnetic Resonance Imaging (MRI) Technology for Lower-Limb Prosthetic Research: Utilising Animal Soft Tissue Specimen and Common Socket Casting Materials

    PubMed Central

    Safari, Mohammad Reza; Rowe, Philip; Buis, Arjan

    2012-01-01

    Lower limb prosthetic socket shape and volume consistency can be quantified using MRI technology. Additionally, MRI images of the residual limb could be used as an input data for CAD-CAM technology and finite element studies. However, the accuracy of MRI when socket casting materials are used has to be defined. A number of six, 46 mm thick, cross-sections of an animal leg were used. Three specimens were wrapped with Plaster of Paris (POP) and the other three with commercially available silicone interface liner. Data was obtained by utilising MRI technology and then the segmented images compared to corresponding calliper measurement, photographic imaging, and water suspension techniques. The MRI measurement results were strongly correlated with actual diameter, surface area, and volume measurements. The results show that the selected scanning parameters and the semiautomatic segmentation method are adequate enough, considering the limit of clinical meaningful shape and volume fluctuation, for residual limb volume and the cross-sectional surface area measurements. PMID:22619599

  16. Studies of behavior of the fuel compound based on the U-Zr micro-heterogeneous quasialloy during cyclic thermal tests

    NASA Astrophysics Data System (ADS)

    Zaytsev, D. A.; Repnikov, V. M.; Soldatkin, D. M.; Solntsev, V. A.

    2017-11-01

    This paper provides the description of temperature cycle testing of U-Zr heterogeneous fuel composition. The composition is essentially a niobium-doped zirconium matrix with metallic uranium filaments evenly distributed over the cross section. The test samples 150 mm long had been fabricated using a fiber-filament technology. The samples were essentially two-bladed spiral mandrel fuel elements parts. In the course of experiments the following temperatures were applied: 350, 675, 780 and 1140 °C with total exposure periods equal to 200, 30, 30 and 6 hours respectively. The fuel element samples underwent post-exposure material science examination including: geometry measurements, metallographic analysis, X-ray phase analysis and electron-microscopic analysis as well as micro-hardness measurement. It has been found that no significant thermal swelling of the samples occurs throughout the whole temperature range from 350 °C up to 1140 °C. The paper presents the structural changes and redistribution of the fuel component over the fuel element cross section with rising temperature.

  17. Factors Associated with Late Engagement to HIV Care in Western Kenya: A Cross-Sectional Study.

    PubMed

    Kwobah, Charles Meja; Braitstein, Paula; Koech, Julius K; Simiyu, Gilbert; Mwangi, Ann W; Wools-Kaloustian, Kara; Siika, Abraham M

    2016-11-01

    Late presentation of patients contributes significantly to the high mortality reported in HIV -care and treatment programs in sub-Saharan Africa. A cross-sectional study was conducted to assess factors associated with late engagement to HIV care at the Academic Model Providing Access to Healthcare in western Kenya. Late engagement was defined as baseline CD4 ≤100 cells/mm 3 . Of the 10 533 participants included in the analysis, 67% were female and mean age was 36.7 years. Overall, 23% of the participants presented late. Factors associated with late engagement included male gender (adjusted odds ratio [AOR]: 1.54, 95% confidence interval [CI]: 1.35-1.75), older age (AOR: 1.62, 95% CI: 1.02-2.56), and longer travel time to clinic (AOR: 1.18, 95% CI: 1.04-1.34). Nearly one-quarter of HIV-infected patients in our setting present with advanced immune suppression at initial encounter. Being male, older age, and living further away from clinic are associated with late engagement to care. © The Author(s) 2015.

  18. Thermal, Spectral and Laser Properties of Er3+:Yb3+:GdMgB₅O10: A New Crystal for 1.5 μm Lasers.

    PubMed

    Huang, Yisheng; Yuan, Feifei; Sun, Shijia; Lin, Zhoubin; Zhang, Lizhen

    2017-12-25

    A novel laser crystal of Er 3+ :Yb 3+ :GdMgB₅O 10 with dimension of 26 × 16 × 12 mm³ was grown successfully from K₂Mo₃O 10 flux by the top seeded solution growth method. The thermal diffusivity and specific heat capacity were measured to calculate the thermal conductivity of the crystal. The absorption and fluorescence properties of the crystal at room temperature were investigated in detail. The Judd-Ofelt method was used to analyze the polarized absorption spectra. The emission cross-section of the ⁴I 13/2 →⁴I 15/2 transition was calculated by the Füchtbauer-Ladenburg formula and the relevant gain cross-sections were estimated. Continuous-wave laser output of 140 mW at 1569 nm with the slope efficiency of 17.8% was demonstrated in a plano-concave resonator. The results reveal that Er 3+ :Yb 3+ :GdMgB₅O 10 crystal is a promising material for 1.5 μm lasers.

  19. Multiscale multifractal detrended cross-correlation analysis of financial time series

    NASA Astrophysics Data System (ADS)

    Shi, Wenbin; Shang, Pengjian; Wang, Jing; Lin, Aijing

    2014-06-01

    In this paper, we introduce a method called multiscale multifractal detrended cross-correlation analysis (MM-DCCA). The method allows us to extend the description of the cross-correlation properties between two time series. MM-DCCA may provide new ways of measuring the nonlinearity of two signals, and it helps to present much richer information than multifractal detrended cross-correlation analysis (MF-DCCA) by sweeping all the range of scale at which the multifractal structures of complex system are discussed. Moreover, to illustrate the advantages of this approach we make use of the MM-DCCA to analyze the cross-correlation properties between financial time series. We show that this new method can be adapted to investigate stock markets under investigation. It can provide a more faithful and more interpretable description of the dynamic mechanism between financial time series than traditional MF-DCCA. We also propose to reduce the scale ranges to analyze short time series, and some inherent properties which remain hidden when a wide range is used may exhibit perfectly in this way.

  20. Effect of image uncertainty on the dosimetry of trigeminal neuralgia irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jursinic, Paul A.; Rickert, Kim; Gennarelli, Thomas A.

    2005-08-01

    Objective: Our objective was to quantify the uncertainty in localization of the trigeminal nerve (TGN) with magnetic resonance imaging (MRI) and computed tomography (CT) and to determine the effect of this uncertainty on gamma-knife dose delivery. Methods: An MR/CT test phantom with 9, 0.6-mm diameter, copper rings was devised. The absolute ring positions in stereotactic space were determined by the angiographic module of the LGP software. The standard deviation, {sigma}, in the difference between the absolute and MR-measured or CT-measured coordinates of the rings was determined. The trigeminal nerve in 52 previously treated patients was contoured and expanded by 1{sigma}more » and 2{sigma} margins to model the uncertainty in the location of the nerve. For gamma-knife treatment, a single isocenter was used and was located at the distal cisternal portion of the trigeminal nerve root. Irradiation methods included a 4-mm collimator, 90 Gy to isocenter and a 4 and 8-mm collimator, 70 Gy to isocenter. A patient outcome survey that sampled pain relief and morbidity was done. Results: The MR coordinate {sigma} was 0.7 mm left-right, 0.8 mm anterior-posterior, and 0.6 mm superior-inferior, and the CT coordinate {sigma} was 0.4 mm left-right, 0.2 mm anterior-posterior, and 0.2 mm superior-inferior. A 45% higher dose line covered the TGN with the 4 and 8-mm method. No significant increase in pain reduction or morbidity occurred. Conclusions: The uncertainty of target location by MRI is more than twice that found in CT imaging. The 4 and 8-mm collimator method covers the trigeminal root cross section with a higher isodose line than does the 4-mm method. This higher dose did not significantly reduce pain or increase morbidity.« less

  1. Sectional anatomy aid for improvement of decompression surgery approach to vertical segment of facial nerve.

    PubMed

    Feng, Yan; Zhang, Yi Qun; Liu, Min; Jin, Limin; Huangfu, Mingmei; Liu, Zhenyu; Hua, Peiyan; Liu, Yulong; Hou, Ruida; Sun, Yu; Li, You Qiong; Wang, Yu Fa; Feng, Jia Chun

    2012-05-01

    The aim of this study was to find a surgical approach to a vertical segment of the facial nerve (VFN) with a relatively wide visual field and small lesion by studying the location and structure of VFN with cross-sectional anatomy. High-resolution spiral computed tomographic multiplane reformation was used to reform images that were parallel to the Frankfort horizontal plane. To locate the VFN, we measured the distances as follows: from the VFN to the paries posterior bony external acoustic meatus on 5 typical multiplane reformation images, to the promontorium tympani and the root of the tympanic ring on 2 typical images. The mean distances from the VFN to the paries posterior bony external acoustic meatus are as follows: 4.47 mm on images showing the top of the external acoustic meatus, 4.20 mm on images with the best view of the window niche, 3.35 mm on images that show the widest external acoustic meatus, 4.22 mm on images with the inferior margin of the sulcus tympanicus, and 5.49 mm on images that show the bottom of the external acoustic meatus. The VFN is approximately 4.20 mm lateral to the promontorium tympani on images with the best view of the window niche and 4.12 mm lateral to the root of the tympanic ring on images with the inferior margin of the sulcus tympanicus. The other results indicate that the area and depth of the surgical wound from the improved approach would be much smaller than that from the typical approach. The surgical approach to the horizontal segment of the facial nerve through the external acoustic meatus and the tympanic cavity could be improved by grinding off the external acoustic meatus to show the VFN. The VFN can be found by taking the promontorium tympani and tympanic ring as references. This improvement is of high potential to expand the visual field to the facial nerve, remarkably without significant injury to the patients compared with the typical approach through the mastoid process.

  2. Ten-Year Cross-Sectional Study of Mechanically Assisted Crevice Corrosion in 1352 Consecutive Patients With Metal-on-Polyethylene Total Hip Arthroplasty.

    PubMed

    Hussey, Daniel K; McGrory, Brian J

    2017-08-01

    Mechanically assisted crevice corrosion (MACC) in metal-on-polyethylene total hip arthroplasty (THA) is of concern, but its prevalence, etiology, and natural history are incompletely understood. From January 2003 to December 2012, 1352 consecutive THA surgeries using a titanium stem, cobalt-chromium alloy femoral head, and highly cross-linked polyethylene liner from a single manufacturer were performed. Patients were followed at 1-year and 5-year intervals for surveillance, but also seen earlier if they had symptoms. Any patient with osteolysis >1 cm (n = 3) or unexplained pain (n = 85) underwent examination, radiographs, complete blood count, erythrocyte sedimentation rate, and C-reactive protein, as well as tests for serum cobalt and chromium levels. Symptomatic MACC was present in 43 of 1352 patients (3.2%). Prevalence of MACC by year of implant ranged from 0% (0 of 61, 2003; 0 of 138, 2005) to 10.5% (17 of 162; 2009). The M/L Taper stem had a greater prevalence (4.9%) of MACC than all other Zimmer (Zimmer, Inc, Warsaw, IN) 12/14 trunnion stem types combined (1.2%; P < .001). Twenty-seven of 43 (62.8%) patients have undergone revision surgery, and 16 of 43 (37.2%) patients have opted for ongoing surveillance. Comparing symptomatic THA patients with and without MACC, no demographic, clinical, or radiographic differences were found. MACC was significantly more common in 0 length femoral heads (compared with both -3.5 mm and +3.5 mm heads). The prevalence of MACC in metal-on-polyethylene hips is higher in this cross-sectional study than previously reported. A significantly higher prevalence was found in patients with M/L Taper style stem and THA performed both in 2009 and also between 2009 and 2012 with this manufacturer. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Morphometric analysis of pulp size in maxillary permanent central incisors correlated with age: An indirect digital study

    PubMed Central

    Ravindra, S. V.; Mamatha, G. P.; Sunita, J. D.; Balappanavar, Aswini Y.; Sardana, Varun

    2015-01-01

    Context: Teeth are hardest part of the body and are least affected by the taphonomic process. They are considered as one of the reliable methods of identification of a person in forensic sciences. Aim: The aim of the following study is to establish morphometeric measurements by AutoCad 2009 (Autodesk, Inc) of permanent maxillary central incisors in different age groups of Udaipur population. Setting and Design: Hospital-based descriptive cross-sectional study carried out in Udaipur. Materials and Methods: A study was carried out on 308 subjects of both genders with the age range of 9-68 years. Standardized intra-oral radiographs were made by paralleling technique and processed. The radiographs were scanned and the obtained images were standardized to the actual size of radiographic film. This was followed by measuring them using software AutoCad 2009. Statistical Analysis Used: F-test, post-hoc test, Pearson's correlation test. Results: For left maxillary central incisor, the total pulp area was found to be of 38.41 ± 12.88 mm and 14.32 ± 7.04 mm respectively. For right maxillary central incisor, the total pulp size was 38.39 ± 14.95 mm and 12.35 ± 5 mm respectively. Males (32.50, 32.87 mm2) had more pulp area when compared with females (28.82, 30.05 mm2). Conclusion: There was a decrease in total pulp area with increasing age which may be attributed to secondary dentin formation. PMID:26816461

  4. Morphometric analysis and clinical application of the working dimensions of cricothyroid membrane in south Indian adults: with special relevance to surgical cricothyroidotomy.

    PubMed

    Prithishkumar, Ivan J; David, Suresh S

    2010-02-01

    To measure the working dimensions of the cricothyroid membrane in the adult south Indian population and to establish the association between the working dimensions and the appropriate endotracheal tube size for the purpose of cricothyroidotomy. Cross-sectional evaluation of 50 fresh adult autopsy cases (35 men, 15 women) in a medical university teaching hospital in South India. Age ranged from 17.0 to 83.0 years. Working dimensions of the membrane in neutral position of neck, in men: width = 8.41 +/- 2.11 mm, height = 6.57 +/- 1.87 mm; in women: width = 6.30 +/- 1.29 mm, height = 5.80 +/- 1.56 mm. Depth of the subglottic larynx at the level of cricoid cartilage: men = 20.73 +/- 1.97 mm, women = 15.62 +/- 1.71 mm. Distance of the lower border of cricothyroid membrane from suprasternal notch in neutral position of neck, in men = 5.18 +/- 1.76 cm, women = 4.72 +/- 1.55 cm; in passively extended neck, men = 7.86 +/- 1.25 cm, women = 8.05 +/- 1.28 cm. Regression equations have been derived to determine endotracheal tube size for cricothyroidotomy, based on distance between sternal notch and chin, and height of the individual (P < 0.05). Working dimensions are smaller in the Indian group compared with western publications. Endotracheal tubes ranging from size 3.0 to 6.0 might be used for cricothyroidotomy in the adult south Indian population.

  5. Quantitative optical frequency domain imaging assessment of in-stent structures in patients with ST-segment elevation myocardial infarction: impact of imaging sampling rate.

    PubMed

    Muramatsu, Takashi; García-García, Hector M; Lee, Il Soo; Bruining, Nico; Onuma, Yoshinobu; Serruys, Patrick W

    2012-01-01

    The impact of the sampling rate (SR) of optical frequency domain imaging (OFDI) on quantitative assessment of in-stent structures (ISS) such as plaque prolapse and thrombus remains unexplored. OFDI after stenting was performed in ST-segment elevation myocardial infarction (STEMI) patients using a TERUMO OFDI system (Terumo Europe, Leuven, Belgium) with 160 frames/s and pullback speed of 20 mm/s. A total of 126 stented segments were analyzed. ISS were classified as either attached or non-attached to stent area boundaries. The volume, mean area and largest area of ISS were assessed according to 4 frequencies of SR, corresponding to distances between the analyzed frames of 0.125, 0.25, 0.50 and 1.0 mm. ISS volume was calculated by integrating cross-sectional ISS areas multiplied by each sampling distance using the disk summation method. The volume and mean area of ISS became significantly larger, while the largest area became significantly smaller as sampling distance became larger (1.11 mm(2) for 0.125 mm vs. 1.00 mm(2) for 1.0 mm, P for trend=0.036). In addition, variance of difference was positively associated with increasing width of sampling distance. Quantification of ISS is significantly influenced by the applied frequency of SR. This should be taken into account when designing future OFDI studies in which quantitative assessment of ISS is critical for the evaluation of STEMI patients.

  6. Visualization of deflagration-to-detonation transitions in a channel with repeated obstacles using a hydrogen-oxygen mixture

    NASA Astrophysics Data System (ADS)

    Maeda, S.; Minami, S.; Okamoto, D.; Obara, T.

    2016-09-01

    The deflagration-to-detonation transition in a 100 mm square cross-section channel was investigated for a highly reactive stoichiometric hydrogen oxygen mixture at 70 kPa. Obstacles of 5 mm width and 5, 10, and 15 mm heights were equally spaced 60 mm apart at the bottom of the channel. The phenomenon was investigated primarily by time-resolved schlieren visualization from two orthogonal directions using a high-speed video camera. The detonation transition occurred over a remarkably short distance within only three or four repeated obstacles. The global flame speed just before the detonation transition was well below the sound speed of the combustion products and did not reach the sound speed of the initial unreacted gas for tests with an obstacle height of 5 and 10 mm. These results indicate that a detonation transition does not always require global flame acceleration beyond the speed of sound for highly reactive combustible mixtures. A possible mechanism for this detonation initiation was the mixing of the unreacted and reacted gas in the vicinity of the flame front convoluted by the vortex present behind each obstacle, and the formation of a hot spot by the shock wave. The final onset of the detonation originated from the unreacted gas pocket, which was surrounded by the obstacle downstream face and the channel wall.

  7. A 1 kWel thermoelectric stack for geothermal power generation - Modeling and geometrical optimization

    NASA Astrophysics Data System (ADS)

    Suter, C.; Jovanovic, Z.; Steinfeld, A.

    2012-06-01

    A thermoelectric stack composed of arrays of Bi-Te alloy thermoelectric converter (TEC) modules is considered for geothermal heat conversion. The TEC modules consist of Al2O3 plates with surface 30×30 mm2 and 127 p-type (Bi0.2Sb0.8)2Te3 and n-type Bi2(Te0.96Se0.04)3 thermoelement pairs, each having a cross-section of 1.05×1.05 mm2, and with a figure-of-merit of 1 and a heat-to-electricity conversion efficiency of ˜5%. A heat transfer model is formulated to couple conduction in the thermoelements with convection between the Al2O3 plates and the water flow in counter-flow channel configuration. The calculated open-circuit voltages are compared to those resulting from the mean temperature differences across the TEC modules computed by CFD. The investigated parameters are: hot water inlet and outlet temperatures (373 - 413 K and 323 - 363 K, respectively), stack length (300 - 1500 mm), thermoelement length (1 - 4 mm) and hot channel heights (0.2 - 2 mm). The heat transfer model is then applied to optimize a 1 kWel stack with hot water inlet at 393 K and outlet at 353 K for either maximum heat-to-electricity conversion efficiency of 2.9% or minimum size of 0.0044 m3.

  8. A radiographic investigation to determine the safety of suture anchor systems for pediatric modified Broström ankle ligament reconstruction.

    PubMed

    Hazratwala, Kaushik; Best, Alistair; Kopplin, Matthew; Giza, Eric; Sullivan, Martin

    2005-03-01

    The modified Broström ligament reconstruction using anchor sutures has been performed in adults with clinical success; however, the safety parameters for the use of suture anchors in adolescent lateral ankle ligament reconstruction have not been established. To perform a radiographic analysis comparing the depth of penetration of suture anchors in adult ankle ligament reconstruction with the average distance of the physis from the tip of the fibula in adolescents. Cross-sectional study, Level of evidence, 4. Forty postoperative ankle radiographs of adult patients who had a modified Broström procedure were compared with 40 normal adolescent ankle radiographs. In the adult group, the distance of the suture anchor penetration from the distal tip of the fibula was measured; in the adolescent group, the distance of the physis from the distal tip of the fibula was measured. The mean depth of the suture anchors was 17 mm (range, 14-21 mm) from the tip of the fibula in the adult group, and the mean distance of the growth plate was 23 mm (range, 18-29 mm) in the adolescent group. Eight radiographs from the adolescent group (20%) had a physis measurement of <22 mm on the anteroposterior or mortise view. Using careful preoperative planning and intraoperative technique, it is possible to safely perform lateral ankle ligament repair in the skeletally immature patient using suture anchors.

  9. The Calibration of the Corneal Light Reflex to Estimate the Degree of an Angle of Deviation.

    PubMed

    Tengtrisorn, Supaporn; Tangkijwongpaisarn, Sitthi; Burachokvivat, Somporn

    2015-12-01

    To measure the conversion factor for the size of an angle of deviation from the clinical photographs of the corneal light reflex. In this cross-sectional study, 19 normal subjects with 20/20 visual acuity were photographed with a digital camera while staring at targets placed five prism diopters (PD) apart from one another on a screen. The subjects were tested at a distance of 1 meter (m) and 4 m from a screen. Measurement of the corneal light reflex displacement for each fixed target was obtained from the photographs. The calibration of the corneal light reflex displacement in millimeters (mm) against the angle of deviation in PD was then analyzed with repeated measure linear regression analysis. At 1 m, the values of 0.047 mm/PD and 0.058 mm/PD were obtained as the conversion factor from reflex displacement to deviated angle for the nasal side and temporal side respectively. At 4 m, the values were 0.050 mm/PD and 0.064 mm/PD for the nasal side and the temporal side respectively. There were significant differences between the values obtained at the different distances, regardless of nasal or temporal side. Conversion factors were presented for estimating the strabismic angle at different distances and gazes. For clinical practice, the use of photographs to estimate the strabismic angle should use different values for different distances and strabismic types.

  10. Effect of the vertical position of the canine on the frictional/orthodontic force ratio of Ni-Ti archwires during the levelling phase of orthodontic treatment.

    PubMed

    Kato, Moeko; Namura, Yasuhiro; Yoneyama, Takayuki; Shimizu, Noriyoshi

    2018-05-31

    This study investigated the effect of the vertical position of the canine on changes in the frictional/orthodontic (F/O) force ratio of nickel-titanium (Ni-Ti) archwires during the initial levelling phase of orthodontic treatment. Frictional and orthodontic forces were measured by using low-friction brackets and Ni-Ti archwires with three different cross-sectional sizes and force types. To simulate canine malocclusion (first premolar extraction case), the upper right canine was displaced gingivally by 1 to 3 mm and the inter-bracket distance between the upper right lateral incisor and second premolar was set at 15 mm or 20 mm. A three-point bending test was performed to measure the orthodontic force of each Ni-Ti archwire. Frictional forces were measured with a universal testing machine and dental arch models by pulling parallel to the end of the archwire at a crosshead speed of 0.5 mm/min. F/O force ratio was calculated and analysed statistically. At a displacement of 3 mm, few archwires had F/O force ratios of less than 1.0, at which orthodontic force overcame frictional force, thus ensuring extrusion of the canine. For effective tooth movement, orthodontists should use Ni-Ti archwires with an F/O force ratio of less than 1.0.

  11. Hydraulic Testing of Polymer Matrix Composite 102mm Tube Section Technical Report

    DTIC Science & Technology

    2018-04-01

    Technical Report ARWSB-TR-18025 Hydraulic Testing of Polymer Matrix Composite 102mm Tube Section Technical Report Lucas B...1. REPORT DATE (DD-MM-YYYY) April 2018 2. REPORT TYPE Technical 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Hydraulic Testing of...Polymer Matrix Composite 102mm Tube Section Technical Report 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER

  12. Testing of the permanent magnet material Mn-Al-C for potential use in propulsion motors for electric vehicles

    NASA Technical Reports Server (NTRS)

    Abdelnour, Z.; Mildrun, H.; Strant, K.

    1981-01-01

    The development of Mn-Al-C permanent magnets is reviewed. The general properties of the material are discussed and put into perspective relative to alnicos and ferrites. The traction motor designer's demands of a permanent magnet for potential use in electric vehicle drives are reviewed. Tests determined magnetic design data and mechanical strength properties. Easy axis hysteresis and demagnetization curves, recoil loops and other minor loop fields were measured over a temperature range from -50 to 150 C. Hysteresis loops were also measured for three orthogonal directions (the one easy and two hard axes of magnetization). Extruded rods of three different diameters were tested. The nonuniformity of properties over the cross section of the 31 mm diameter rod was studied. Mechanical compressive and bending strength at room temperature was determined on individual samples from the 31 mm rod.

  13. Micro-fabricated packed gas chromatography column based on laser etching technology.

    PubMed

    Sun, J H; Guan, F Y; Zhu, X F; Ning, Z W; Ma, T J; Liu, J H; Deng, T

    2016-01-15

    In this work, a micro packed gas chromatograph column integrated with a micro heater was fabricated by using laser etching technology (LET) for analyzing environmental gases. LET is a powerful tool to etch deep well-shaped channels on the glass wafer, and it is the most effective way to increase depth of channels. The fabricated packed GC column with a length of over 1.6m, to our best knowledge, which is the longest so far. In addition, the fabricated column with a rectangular cross section of 1.2mm (depth) × 0.6mm (width) has a large aspect ratio of 2:1. The results show that the fabricated packed column had a large sample capacity, achieved a separation efficiency of about 5800 plates/m and eluted highly symmetrical Gaussian peaks. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. A revised velocity-reversal and sediment-sorting model for a high-gradient, pool-riffle stream

    USGS Publications Warehouse

    Thompson, D.M.; Wohl, E.E.; Jarrett, R.D.

    1996-01-01

    Sediment-sorting processes related to varying channel-bed morphology were investigated from April to November 1993 along a 1-km pool-riffle and step-pool reach of North Saint Vrain Creek, a small mountain stream in the Rocky Mountains of northern Colorado. Measured cross-sectional areas of flow were used to suggest higher velocities in pools than in riffles at high flow. Three hundred and sixteen tracer particles, ranging in size from 16 mm to 256 mm, were placed in two separate pool-riffle-pool sequences and used to assess sediment-sorting patterns and sediment-transport competence variations. Tracer-particle depositional evidence indicated higher sediment-transport competence in pools than in riffles at high flow. Pool-riffle sediment sorting may be created by velocity reversals, and more localized sorting results from gravitational forces along the upstream sloping portion of the channel bed located at the downstream end of pools.

  15. Further Development of Scaffolds for Regeneration of Nerves

    NASA Technical Reports Server (NTRS)

    Sakamoto, Jeffrey; Tuszynski, Mark

    2009-01-01

    Progress has been made in continuing research on scaffolds for the guided growth of nerves to replace damaged ones. The scaffolds contain pores that are approximately cylindrical and parallel, with nearly uniform widths ranging from tens to hundreds of microns. At the earlier stage of development, experimental scaffolds had been made from agarose hydrogel. Such a scaffold was made in a multistep process in which poly(methyl methacrylate) [PMMA] fibers were used as templates for the pores. The process included placement of a bundle of the PMMA fibers in a tube, filling the interstices in the tube with a hot agarose solution, cooling to turn the solution into a gel, and then immersion in acetone to dissolve the PMMA fibers. The scaffolds were typically limited to about 25 pores per scaffold, square cross sections of no more than about 1.5 by 1.5 mm, and lengths of no more than about 2 mm.

  16. Wall-ablative laser-driven in-tube accelerator

    NASA Astrophysics Data System (ADS)

    Sasoh, Akihiro; Suzuki, Shingo; Matsuda, Atsushi

    2008-05-01

    The laser-driven in-tube accelerator in which the propellant is supplied from laser-ablated gas from the tube wall was developed. Proof-of concept demonstrations of vertical launch were successfully done. The device had a 25mm X 25mm square cross-section; two opposing walls were made of polyacetal and acted as the propellant, the other two acrylic window with guide grooves to the projectile. The upper end of the launch tube was connected to a vacuum chamber of an inner volume of 0.8 m2, in which the initial pressure was set to lower than 20 Pa. With plugging the bottom end of the launch tube, a momentum coupling coefficient exceeding 2.5 mN/W was obtained. Even with the bottom end connected to the same vacuum chamber through a different duct, the projectile was vertical launched successfully, obtaining 0.14 mN/W.

  17. TOMOGRAPHIC MORPHOLOGICAL STUDY OF THE CRANIUM AND ITS CORRELATION WITH CRANIAL HALO USE IN ADULTS

    PubMed Central

    ALMEIDA, TIAGO FERREIRA DE; CHARAFEDDINE, HOMAR TOLEDO; ARAÚJO, FERNANDO FLORES DE; CRISTANTE, ALEXANDRE FOGAÇA; MARCON, RAPHAEL MARTUS; LETAIF, OLAVO BIRAGHI

    2017-01-01

    ABSTRACT Objective: To evaluate using tomographic study the thickness of the cranial board at the insertions points of the cranial halo pins in adults Methods: This is a retrospective, cross-sectional, descriptive analysis of Computed Tomography (CT) scans of adult patients' crania. The study included adults between 20 and 50 years without cranial abnormalities. We excluded any exam with cranial abnormalities Results: We analyzed 50 CT scans, including 27 men and 23 women, at the original insertion points and alternative points (1 and 2 cm above the frontal and parietal bones). The average values were 7.4333 mm in the frontal bone and 6.0290 mm in the parietal bone Conclusion: There was no statistically significant difference between the classical and alternative points, making room for alternative fixings and safer introduction of the pins, if necessary.Level of Evidence II, Retrospective Study. PMID:28642643

  18. Nd- And Er-Doped Phosphate Glass For Fiber Laser.

    NASA Astrophysics Data System (ADS)

    Yamashita, Toshiharu T.

    1990-02-01

    Laser fibers prepared from Nd- and Er-doped phosphate glass possessing a large stimulated emission cross section have been investigated both in a single fiber and in a fiber bundle. In the single fiber, continuous wave oscillations were successfully obtained at 1.054 p.m and 1.366 µm on a high Nd-doped single-mode fiber of 10 mm in length and also at 1.535 pm in a Er-doped single-mode fiber, sensitized by Nd, Yb. Especially, a low threshold of 1 mw and a high slope-efficiency of 50% were achieved in 1.054 pm laser oscillation on a Nd-doped fiber, end-pumped with a laser diode. A fiber bundle of phosphate glass doped with 8 wt% Nd2O3 yielded an average output power of 100 W at 50 pps where the bundle was 4.6 mm in diameter and was side-pumped with flash lamps.

  19. Doublet Pulse Coherent Laser Radar for Tracking of Resident Space Objects

    NASA Technical Reports Server (NTRS)

    Prasad, Narasimha S.; Rudd, Van; Shald, Scott; Sandford, Stephen; Dimarcantonio, Albert

    2014-01-01

    In this paper, the development of a long range ladar system known as ExoSPEAR at NASA Langley Research Center for tracking rapidly moving resident space objects is discussed. Based on 100 W, nanosecond class, near-IR laser, this ladar system with coherent detection technique is currently being investigated for short dwell time measurements of resident space objects (RSOs) in LEO and beyond for space surveillance applications. This unique ladar architecture is configured using a continuously agile doublet-pulse waveform scheme coupled to a closed-loop tracking and control loop approach to simultaneously achieve mm class range precision and mm/s velocity precision and hence obtain unprecedented track accuracies. Salient features of the design architecture followed by performance modeling and engagement simulations illustrating the dependence of range and velocity precision in LEO orbits on ladar parameters are presented. Estimated limits on detectable optical cross sections of RSOs in LEO orbits are discussed.

  20. Objective measurement of accommodative biometric changes using ultrasound biomicroscopy

    PubMed Central

    Ramasubramanian, Viswanathan; Glasser, Adrian

    2015-01-01

    PURPOSE To demonstrate that ultrasound biomicroscopy (UBM) can be used for objective quantitative measurements of anterior segment accommodative changes. SETTING College of Optometry, University of Houston, Houston, Texas, USA. DESIGN Prospective cross-sectional study. METHODS Anterior segment biometric changes in response to 0 to 6.0 diopters (D) of accommodative stimuli in 1.0 D steps were measured in eyes of human subjects aged 21 to 36 years. Imaging was performed in the left eye using a 35 MHz UBM (Vumax) and an A-scan ultrasound (A-5500) while the right eye viewed the accommodative stimuli. An automated Matlab image-analysis program was developed to measure the biometry parameters from the UBM images. RESULTS The UBM-measured accommodative changes in anterior chamber depth (ACD), lens thickness, anterior lens radius of curvature, posterior lens radius of curvature, and anterior segment length were statistically significantly (P < .0001) linearly correlated with accommodative stimulus amplitudes. Standard deviations of the UBM-measured parameters were independent of the accommodative stimulus demands (ACD 0.0176 mm, lens thickness 0.0294 mm, anterior lens radius of curvature 0.3350 mm, posterior lens radius of curvature 0.1580 mm, and anterior segment length 0.0340 mm). The mean difference between the A-scan and UBM measurements was −0.070 mm for ACD and 0.166 mm for lens thickness. CONCLUSIONS Accommodating phakic eyes imaged using UBM allowed visualization of the accommodative response, and automated image analysis of the UBM images allowed reliable, objective, quantitative measurements of the accommodative intraocular biometric changes. PMID:25804579

  1. Blood pressure after recent stroke: baseline findings from the secondary prevention of small subcortical strokes trial.

    PubMed

    White, Carole L; Pergola, Pablo E; Szychowski, Jeff M; Talbert, Robert; Cervantes-Arriaga, Amin; Clark, Heather D; Del Brutto, Oscar H; Godoy, Ivan Esteban; Hill, Michael D; Pelegrí, Antoni; Sussman, Craig R; Taylor, Addison A; Valdivia, José; Anderson, Dave C; Conwit, Robin; Benavente, Oscar R

    2013-09-01

    Hypertension is the most powerful risk factor for stroke. The aim of this study was to characterize baseline blood pressure in participants in the Secondary Prevention of Small Subcortical Strokes trial. For this cross-sectional analysis, participants were categorized by baseline systolic blood pressure (SBP) < 120, 120-139, 140-159, 160-179, and ≥ 180 mm Hg and compared on demographic and clinical characteristics. Predictors of SBP < 140 mm Hg were examined. Mean SBP was 143±19 mm Hg while receiving an average of 1.7 antihypertensive medications; SBP ≥ 140 mm Hg for 53% and ≥ 160 mm Hg for 18% of the 3,020 participants. Higher SBP was associated with a history of hypertension and hypertension for longer duration (both P < 0.0001). Higher SBPs were associated with more extensive white matter disease on magnetic resonance imaging (P < 0.0001). There were significant differences in entry-level SBP when participants were categorized by race and region (both P < 0.0001). Black participants were more likely to have SBP ≥ 140 mm Hg. Multivariable logistic regression showed an independent effect for region with those from Canada more likely (odds ratio = 1.7; 95% confidence interval, 1.29, 2.32) to have SBP < 140 mm Hg compared with participants from United States. In this cohort with symptomatic lacunar stroke, more than half had uncontrolled hypertension at approximately 2.5 months after stroke. Regional, racial, and clinical differences should be considered to improve control and prevent recurrent stroke.

  2. Evaluation of radiographic, computed tomographic, and cadaveric anatomy of the head of boa constrictors.

    PubMed

    Banzato, Tommaso; Russo, Elisa; Di Toma, Anna; Palmisano, Giuseppe; Zotti, Alessandro

    2011-12-01

    To evaluate the radiographic, computed tomographic (CT), and cadaveric anatomy of the head of boa constrictors. 4 Boa constrictor imperator cadavers. Cadavers weighed 3.4 to 5.6 kg and had a body length ranging from 189 to 221 cm. Radiographic and CT images were obtained with a high-detail screen-film combination, and conventional CT was performed with a slice thickness of 1.5 mm. Radiographic images were obtained in ventrodorsal, dorsoventral, and left and right laterolateral recumbency; CT images were obtained with the animals positioned in ventral recumbency directly laying on a plastic support. At the end of the radiographic and CT imaging session, 2 heads were sectioned following a stratigraphic approach; the other 2, carefully maintained in the same position on the plastic support, were moved into a freezer (-20°C) until completely frozen and then sectioned into 3-mm slices, respecting the imaging protocol. The frozen sections were cleaned and then photographed on each side. Anatomic structures were identified and labeled on gross anatomic images and on the corresponding CT or radiographic image with the aid of available literature. Radiographic and CT images provided high detail for visualization of bony structures; soft tissues were not easily identified on radiographic and CT images. Results provide an atlas of stratigraphic and cross-sectional gross anatomy and radiographic and CT anatomy of the heads of boa constrictors that might be useful in the interpretation of any imaging modality in this species.

  3. Comparisons of the diagnostic accuracies of optical coherence tomography, micro-computed tomography, and histology in periodontal disease: an ex vivo study

    PubMed Central

    2017-01-01

    Purpose Optical coherence tomography (OCT) is a noninvasive diagnostic technique that may be useful for both qualitative and quantitative analyses of the periodontium. Micro-computed tomography (micro-CT) is another noninvasive imaging technique capable of providing submicron spatial resolution. The purpose of this study was to present periodontal images obtained using ex vivo dental OCT and to compare OCT images with micro-CT images and histologic sections. Methods Images of ex vivo canine periodontal structures were obtained using OCT. Biologic depth measurements made using OCT were compared to measurements made on histologic sections prepared from the same sites. Visual comparisons were made among OCT, micro-CT, and histologic sections to evaluate whether anatomical details were accurately revealed by OCT. Results The periodontal tissue contour, gingival sulcus, and the presence of supragingival and subgingival calculus could be visualized using OCT. OCT was able to depict the surface topography of the dentogingival complex with higher resolution than micro-CT, but the imaging depth was typically limited to 1.2–1.5 mm. Biologic depth measurements made using OCT were a mean of 0.51 mm shallower than the histologic measurements. Conclusions Dental OCT as used in this study was able to generate high-resolution, cross-sectional images of the superficial portions of periodontal structures. Improvements in imaging depth and the development of an intraoral sensor are likely to make OCT a useful technique for periodontal applications. PMID:28261522

  4. Reduced Pineal Volume in Alzheimer Disease: A Retrospective Cross-sectional MR Imaging Study.

    PubMed

    Matsuoka, Teruyuki; Imai, Ayu; Fujimoto, Hiroshi; Kato, Yuka; Shibata, Keisuke; Nakamura, Kaeko; Yokota, Hajime; Yamada, Kei; Narumoto, Jin

    2018-01-01

    Purpose To evaluate pineal volume in patients with Alzheimer disease (AD), patients with mild cognitive impairment (MCI), and healthy control subjects and to correlate the findings with results of cognitive testing and brain parenchymal volumes. Materials and Methods The ethics committee approved this retrospective study. The participants included 63 patients with AD, 33 patients with MCI, and 24 healthy control subjects. There were 36 men and 84 women, with a mean age (±standard deviation) of 76.7 years ± 7.6. The pineal gland volume and pineal parenchymal volume were measured by using three-dimensional volumetric magnetic resonance imaging (T1-weighted magnetization-prepared rapid gradient-echo sequence; spatial resolution, 0.9 × 0.98 × 0.98 mm). With age and total intracranial volume as covariates, analysis of covariance with the Bonferroni post hoc test was performed to compare the pineal volume among the AD, MCI, and control groups. Multiple regression analyses were used to identify predictor variables associated with pineal volume. Results The mean pineal gland volume in patients with AD (72.3 mm 3 ± 5.4; 95% confidence interval [CI]: 61.5 mm 3 , 83.1 mm 3 ) was significantly smaller than that in control subjects (102.1 mm 3 ± 9.0; 95% CI: 84.4 mm 3 , 119.9 mm 3 ) (P = .019). The mean pineal parenchymal volume in patients with AD (63.8 mm 3 ± 4.2; 95% CI: 55.4 mm 3 , 72.1 mm 3 ) was significantly smaller than that in patients with MCI (81.7 mm 3 ± 5.8; 95% CI: 70.3 mm 3 , 93.1 mm 3 ; P = .044) and control subjects (89.1 mm 3 ± 6.9; 95% CI: 75.4 mm 3 , 102.9 mm 3 ; P = .009). Multiple regression analyses demonstrated that the Mini-Mental State Examination score and total intracranial volume were significant independent predictors of both pineal gland volume and pineal parenchymal volume (P < .001). Conclusion Pineal volume reduction showed correlation with cognitive decline and thus might be useful to predict cognitive decline in patients with AD. © RSNA, 2017.

  5. The effect of using an inverted master cone in a lateral compaction technique on the density of the gutta-percha fill.

    PubMed

    Wu, Min-Kai; de Groot, Sjoerd D; van der Sluis, Luc W M; Wesselink, Paul R

    2003-09-01

    We sought to measure and calculate the percentage of the gutta-percha-filled area in the apical root canal after the use of a standardized or inverted master cone in cold lateral compaction.Study design Two groups of extracted mandibular premolars with a single canal were instrumented with instruments of the same size; furthermore, they were obturated with laterally compacted gutta-percha cones with AH26 used as a sealer. In the first group, a standardized master cone was used with its narrow end in an apical position, whereas in the other group, an inverted master cone was used with its wide end in an apical position. The 2 master cones had the same apical diameter and fit in the apical canal. After lateral compaction, horizontal sections were cut at a level 3 and 5 mm from the apex of each filled tooth. Photographs of the sections were taken by using a microscope equipped with a digital camera; the photos were then scanned as tagged-image file format images. The cross-sectional area of the canal and the gutta-percha were measured by using an image-analysis program. The percentage of gutta-percha-filled area was calculated. At both levels, the inverted master cone produced a significantly higher percentage, statistically, of gutta-percha-filled area than did the standardized master cone (P =.001 at 3 mm; P =.012 at 5 mm). The use of an inverted master cone in cold lateral compaction may facilitate the apical placement of accessory cones, significantly increasing the volume of gutta-percha while reducing the volume of sealer in the apical root canal.

  6. Ethnic and socioeconomic influences on childhood blood pressure: the Child Heart and Health Study in England.

    PubMed

    Thomas, Claudia; Nightingale, Claire M; Donin, Angela S; Rudnicka, Alicja R; Owen, Christopher G; Cook, Derek G; Whincup, Peter H

    2012-11-01

    Compared to UK white European adults, UK black African-Caribbean adults have higher mean SBP and DBP; UK South Asian adults have higher mean DBP but lower SBP. Information on blood pressure (BP) in UK children from different ethnic groups is limited. The aim of this study was to compare BP levels in UK children of black African-Caribbean, South Asian and white European origin. BP and body build were measured in 5666 children in a cross-sectional study of UK primary school children of South Asian, black African-Caribbean and white European origin aged 9-10 years. Ethnic and socioeconomic differences in BP were obtained from multilevel linear regression models. After adjustment for height and adiposity, black African-Caribbean children had lower mean SBP than white Europeans [difference 1.62  mmHg, 95% confidence interval (CI) 0.86-2.38  mmHg], whereas mean DBP was similar (difference 0.58  mmHg, 95% CI -0.12 to 1.28  mmHg). The lower SBP was particularly marked in black African rather than Caribbean children (P  =  0.002). South Asian children had lower mean SBP (difference 1.10  mmHg, 95% CI 0.34-1.86  mmHg) than white Europeans and higher mean DBP (difference 1.07  mmHg, 95% CI 0.37-1.76  mmHg). The higher mean DBP was particularly marked among Indian and Bangladeshi, rather than Pakistani, children (P  =  0.01). BP was unrelated to socioeconomic circumstances; ethnic differences in BP were not affected by socioeconomic adjustment. A BP pattern similar to that in adults is present in UK South Asian but not in UK black African-Caribbean children at 9-10 years.

  7. Ultrasonographic characteristics of the abdominal esophagus and cardia in dogs.

    PubMed

    Gory, Guillaume; Rault, Delphine N; Gatel, Laure; Dally, Claire; Belli, Patrick; Couturier, Laurent; Cauvin, Eddy

    2014-01-01

    Differential diagnoses for regurgitation and vomiting in dogs include diseases of the gastroesophageal junction. The purpose of this cross-sectional study was to describe ultrasonographic characteristics of the abdominal esophagus and gastric cardia in normal dogs and dogs with clinical disease involving this region. A total of 126 dogs with no clinical signs of gastrointestinal disease and six dogs with clinical diseases involving the gastroesophageal junction were included. For seven euthanized dogs, ultrasonographic features were also compared with gross pathology and histopathology. Cardial and abdominal esophageal wall thicknesses were measured ultrasonographically for all normal dogs and effects of weight, sex, age, and stomach filling were tested. Five layers could be identified in normal esophageal and cardial walls. The inner esophageal layer was echogenic, corresponding to the cornified mucosa and glandular portion of the submucosa. The cardia was characterized by a thick muscularis, and a transitional zone between echogenic esophageal and hypoechoic gastric mucosal layers. Mean (±SD) cardial wall thicknesses for normal dogs were 7.6 mm (±1.6), 9.7 mm (±1.8), 10.8 mm (±1.6), 13.3 mm (±2.5) for dogs in the <10 kg, 10-19.9 kg, 20-29.9 kg and ≥30 kg weight groups, respectively. Mean (±SD) esophageal wall thicknesses were: 4.1 mm (±0.6), 5.1 mm (±1.3), 5.6 mm (±1), and 6.4 mm (±1.1) for the same weight groups, respectively. Measurements of wall thickness were significantly correlated with dog weight group. Ultrasonography assisted diagnosis in all six clinically affected dogs. Findings supported the use of transabdominal ultrasonography as a diagnostic test for dogs with suspected gastroesophageal disease. © 2014 American College of Veterinary Radiology.

  8. Systolic blood pressure target in systemic arterial hypertension: Is lower ever better? Results from a community-based Caucasian cohort.

    PubMed

    Di Nora, Concetta; Cioffi, Giovanni; Iorio, Annamaria; Rivetti, Luigi; Poli, Stefano; Zambon, Elena; Barbati, Giulia; Sinagra, Gianfranco; Di Lenarda, Andrea

    2018-02-01

    Extensive evidence exists about the prognostic role of systolic blood pressure (SBP) reduction ≤140mmHg. Recently, the SPRINT trial successfully tested the strategy of lowering SBP<120mmHg in patients with arterial hypertension (AH). To assess whether the SPRINT results are reproducible in a real world community population. Cross-sectional, population-based study analyzing data of 24,537 Caucasian people with AH from the Trieste Observatory of CV disease, 2010 to 2015. We selected and divided 2306 subjects with AH according to the SPRINT trial criteria; similarly, SPRINT clinical outcomes were considered. Study patients median age was 75±8years, two third male, one third had ischemic heart disease. They were older, with lower body mass index, higher SBP and Framingham CV risk score than the SPRINT patients. Three-hundred-sixty-eight patients (16%) had SBP<120mmHg. During 48 [36-60] months of follow-up, 751 patients (32%) experienced a major adverse cardiac event (MACE). The SBP <120mmHg group had higher incidence of MACE, CV deaths and all-cause death than SBP≥120mmHg group (37% vs 31%; 10% vs 4%; 19% vs 10%, all p<0.05). The condition of SBP<120mmHg was an independent predictor of MACE in multivariate Cox analysis together with older age, male gender, higher Charlson score. In our experience, the SBP<120mmHg condition is associated with worse clinical outcomes, suggesting the SPRINT results are not reproducible tout court in Caucasian community populations. These differences should be taken as a warning against aggressive reducing of SBP<120mmHg. Copyright © 2017 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  9. Ocular biometric measurements in cataract surgery candidates in Portugal

    PubMed Central

    Hoffer, Kenneth J.; Ribeiro, Filomena; Ribeiro, Paulo; O’Neill, João G.

    2017-01-01

    Objective Describe the ocular biometric parameters and their associations in a population of cataract surgery candidates. Methods A cross-sectional study of 13,012 eyes of 6,506 patients was performed. Biometric parameters of the eyes were measured by optical low-coherence reflectometry. The axial length (AL), mean keratometry (K) and astigmatism, anterior chamber depth (ACD) (epithelium to lens), lens thickness (LT), and Corneal Diameter (CD) were evaluated. Results The mean age was 69 ± 10 years (44–99 years). Mean AL, Km, and ACD were 23.87 ± 1.55 mm (19.8–31.92 mm), 43.91 ± 1.71 D (40.61–51.14 D), and 3.25 ± 0.44 mm (2.04–5.28 mm), respectively. The mean LT was 4.32 ± 0.49 mm (2.73–5.77 mm) and the mean CD was 12.02 ± 0.46 mm (10.50–14.15 mm). The mean corneal astigmatism was 1.08 ± 0.84 D (0.00–7.58 D) and 43.5% of eyes had astigmatism ≥ 1.00 D. Male patients had longer AL and ACDs (p < .001) and flatter corneas (p < .001). In regression models considering age, gender, Km, ACD, LT, and CD, a longer AL was associated with being male and having higher ACD, LT and CD. Conclusions These data represent normative biometric values for the Portuguese population. The greatest predictor of ocular biometrics was gender. There was no significant correlation between age and AL, ACD, or Km. These results may be relevant in the evaluation of refractive error and in the calculation of intraocular lens power. PMID:28982150

  10. Dentine chips produced by nickel-titanium rotary instruments.

    PubMed

    Guppy, D R; Curtis, R V; Ford, T R

    2000-12-01

    This study aimed to compare the cross-sectional shape of two nickel-titanium rotary instruments, namely ProFile and Quantec files, both ISO 25, 0.06 taper, and sought to relate this to the chips produced by cutting dentine. A limited comparison was made with stainless steel engine reamers. First, five files of each type were sectioned transversely at 12 mm, 8 mm and 4 mm from the tip and examined by scanning electron microscopy. The cutting angles were assessed by a direct measurement technique which allowed for the inclination of a cutting edge to the root canal. Second, eight samples of cutting debris were collected from instrumentation by each type of nickel-titanium file and four samples from the engine reamers. The major and minor axis, area and roundness of the dentine chips in each sample were measured using computerized particle analysis. The results demonstrated that all files had a negative cutting angle which varied at the different levels (ProFiles range 69.4 degrees to 58.4 degrees and Quantec range 74.8 degrees to 56.8 degrees). The consistency within files of the same type was good as demonstrated by low standard deviations, except for Quantec files at the 4 mm level where higher standard deviations of 4.1 degrees and 5.5 degrees for the two blades were found. The chip analysis showed significant differences between chips produced by ProFile and Quantec files (P < 0.05). The latter were larger and rounder. The chips from the ProFile and the engine reamer chips were similar in dimension (P > 0.05). No simple relationship existed between file geometry and the dentine chips produced during instrumentation.

  11. Age-related differences in women's foot shape.

    PubMed

    Ansuategui Echeita, Jone; Hijmans, Juha M; Smits, Sharon; Van der Woude, Lucas H V; Postema, Klaas

    2016-12-01

    Describe age-related differences in women's foot shape using a wide range of measurements and ages. Cross-sectional, observational study. Six foot-shape measurements of each foot: foot lengths, ball widths, ball circumferences, low instep circumferences, high instep circumferences, and heel instep circumference. 168 women from 20 to over 80 years of age, divided into seven age categories, were included. Older women had significantly greater foot-shape measurements, even after adjusting for Body Mass Index. Ball widths increased 3.1-4.0mm per decade, ball circumferences 5.6-7.4mm per decade, high instep circumferences 0.4-4.8mm per decade, and heel instep circumferences 1.8-1.9mm per decade. Ball widths, ball circumferences, and left high instep circumference plateaued in the 70-75 years-of-age category, and decreased in the oldest age category. For low instep circumference, age did not prevail significantly over Body Mass Index. Foot length was not associated with age. This study described women's progressive foot-shape changes with age. The findings provide a better understanding of foot-shape changes, mainly found in the forefoot. It demonstrates that for a good fit, shoe design for older adults and for younger adults should differ. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. [The interarm blood pressure difference in the critically ill patient].

    PubMed

    Valls Matarín, Josefa; del Cotillo Fuente, Mercedes; Quintana Riera, Salvador; de la Sierra Iserte, Alejandro

    2014-02-04

    To evaluate the prevalence of a difference in systolic blood pressure (SBPd) ≥ 10 mmHg between arms in patients admitted in a Critical Care Unit and to examine the clinical characteristics associated with such blood pressure difference. Observational cross-sectional study. Two blood pressure measurements in each arm were carried out at unit admission. The firstly measured arm was chosen at random. One-hundred and sixty-eight patients were studied, with a mean age of 61 (SD=16), 67.3% male and 45% with a previous hypertension diagnosis. On admission, 27.4% presented SBPd ≥ 10 mmHg. Among them, 54% had higher SBP in the right arm and 46% in the left one. A SBPd ≥ 10 mmHg was associated with a previous hypertension diagnosis (67.4 versus 36.9%; P<.001) and with reduced consciousness (76.1 versus 52.5%; P=.006). Over a quarter of critically ill patients have a SBPd ≥ 10 mmHg between arms. This feature is associated with a previous hypertension diagnosis and reduced consciousness. It should be assessed in the future if the choice of a control arm would help improve patient's care as it would become a more accurate guide for hemodynamic management. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  13. WWW mesothelioma information: Surfing on unreliable waters. A cross-sectional study into the content and quality of online informational resources for mesothelioma patients.

    PubMed

    Soloukey Tbalvandany, S Sadaf; Maat, A Alexander P W M; Cornelissen, R Robin; Nuyttens, J Joost J M E; Takkenberg, J Johanna J M

    2018-06-01

    Malignant Mesothelioma (MM) is a rare asbestos related disease mostly diagnosed in low-skilled patients. The decision-making process for MM treatment is complicated, making an adequate provision of information necessary. The objective of this study is to assess the content and quality of online informational resources available for Dutch MM patients. The first 100 hits of a Google search were studied using the JAMA benchmarks, the Modified Information Score (MIS) and the International Patient Decision Aid Standard Scoring (IPDAS). A total of 37 sources were included. Six of the 37 resources were published by hospitals. On average, the informational resources scored 37 points on the MIS (scale 0-100). The resources from a (bio)medical sources scored the best on this scale. However, on the domain of use of language, these resources scored the worst. The current level of medical content and quality of online informational resources for patient with MM is below average and cannot be used as decision-aids for patients. The criteria used in this article could be used for future improvements of online informational resources for patients, both online, offline and through health education in the care path. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Particle trajectories in thermal counterflow of superfluid helium in a wide channel of square cross section

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    La Mantia, Marco, E-mail: lamantia@nbox.troja.mff.cuni.cz

    The motion of micrometer-sized solid hydrogen particles in thermal counterflow of superfluid helium is studied experimentally by using the particle tracking velocimetry technique. The investigated quantum flow occurs in a square channel of 25 mm sides and 100 mm length, appreciably wider than those employed in previous related experiments. Flow velocities up to 10 mm/s are obtained, corresponding to temperatures between about 1.3 K and 2.1 K, and applied heat fluxes between ca. 50 W/m{sup 2} and 500 W/m{sup 2}. The character of the obtained particle trajectories changes significantly as the imposed mean flow velocity increases. At thermal counterflow velocitiesmore » lower than approximately 1 mm/s, the particle tracks appear straighter than at larger velocities. On the basis of the current understanding of the underlying physics, it is argued that the outcome is most likely due to the transition to the turbulent state of the investigated flow as, for narrower channels, this transition was reported to occur at larger velocities. The present results confirm that, at least in the parameter ranges investigated to date, the transition to turbulence in thermal counterflow depends on the geometry of the channel where this quantum flow develops.« less

  15. Array of aligned and dispersed carbon nanotubes and method of producing the array

    DOEpatents

    Ivanov, Ilia N [Knoxville, TN; Simpson, John T [Clinton, TN; Hendricks, Troy R [Knoxville, TN

    2012-06-19

    An array of aligned and dispersed carbon nanotubes includes an elongate drawn body including a plurality of channels extending therethrough from a first end to a second end of the body, where the channels have a number density of at least about 100,000 channels/mm.sup.2 over a transverse cross-section of the body. A plurality of carbon nanotubes are disposed in each channel, and the carbon nanotubes are sufficiently dispersed and aligned along a length of the channels for the array to comprise an average resistivity per channel of about 9700 .OMEGA.m or less.

  16. Array of aligned and dispersed carbon nanotubes and method of producing the array

    DOEpatents

    Ivanov, Ilia N; Simpson, John T; Hendricks, Troy R

    2013-06-11

    An array of aligned and dispersed carbon nanotubes includes an elongate drawn body including a plurality of channels extending therethrough from a first end to a second end of the body, where the channels have a number density of at least about 100,000 channels/mm.sup.2 over a transverse cross-section of the body. A plurality of carbon nanotubes are disposed in each channel, and the carbon nanotubes are sufficiently dispersed and aligned along a length of the channels for the array to comprise an average resistivity per channel of about 9700 .OMEGA.m or less.

  17. A laser system to remotely sense bird movements

    NASA Technical Reports Server (NTRS)

    Korschgen, C. E.; Green, W. L.; Seasholtz, R. G.

    1983-01-01

    The design and operation of a laser detection system for migrating birds are presented. A battery-powered class-III laser (operating at 904 nm, pulse-repetition rate 5 kHz, pulse duration 100 nsec, and peak power 25 W) and a photodiode receiver are mounted on poles at height 10 m and distance 850 m and equipped with 135-mm f/2.8 collimating lenses; beam diameter at the receiver is 1.7 m. The microprocessor-controlled system is found to detect the passing of an object as small as 30 sq cm in cross section at a distance of 425 m.

  18. Using a Gatling-Gun Configured Micro Pulsed Plasma Thruster as a Means to Control Micro Satellites with Extreme Precision

    DTIC Science & Technology

    2011-03-01

    machine gun , or distributor cap in an automobile. In a Gatling- Gun , when the barrel rotates it collects a round and as the round rotates, it comes...ejected and another is fed into the barrel . This design allows multiple rounds to be fired from the gun very quickly, and still prevent the barrel from...T6061 aluminum and had dimensions of (127 x 76.2 x76.2) mm, cross sectional area of 5.80644 *10-3 m2 and a volume of 7.374*10-4 m3. Using the volume

  19. Effect of ion-beam treatment on structure and fracture resistance of 12Cr1MoV steel under static, cyclic and dynamic loading

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Panin, S. V., E-mail: svp@ispms.tsc.ru; Vlasov, I. V., E-mail: good0@yandex.ru; Sergeev, V. P., E-mail: retc@ispms.tsc.ru

    2015-10-27

    Features of the structure and properties modification of 12Cr1MoV steel subjected to irradiation by zirconium ion beam have been investigated with the use of optical and electron microscopy as well as microhardness measurement. It has been shown that upon treatment the structure modification occurred across the entire cross-section of specimens with the thickness of 1 mm. Changes in the mechanical properties of these specimens under static, cyclic and impact loading are interpreted in terms of identified structure changes.

  20. Extension of PENELOPE to protons: simulation of nuclear reactions and benchmark with Geant4.

    PubMed

    Sterpin, E; Sorriaux, J; Vynckier, S

    2013-11-01

    Describing the implementation of nuclear reactions in the extension of the Monte Carlo code (MC) PENELOPE to protons (PENH) and benchmarking with Geant4. PENH is based on mixed-simulation mechanics for both elastic and inelastic electromagnetic collisions (EM). The adopted differential cross sections for EM elastic collisions are calculated using the eikonal approximation with the Dirac-Hartree-Fock-Slater atomic potential. Cross sections for EM inelastic collisions are computed within the relativistic Born approximation, using the Sternheimer-Liljequist model of the generalized oscillator strength. Nuclear elastic and inelastic collisions were simulated using explicitly the scattering analysis interactive dialin database for (1)H and ICRU 63 data for (12)C, (14)N, (16)O, (31)P, and (40)Ca. Secondary protons, alphas, and deuterons were all simulated as protons, with the energy adapted to ensure consistent range. Prompt gamma emission can also be simulated upon user request. Simulations were performed in a water phantom with nuclear interactions switched off or on and integral depth-dose distributions were compared. Binary-cascade and precompound models were used for Geant4. Initial energies of 100 and 250 MeV were considered. For cases with no nuclear interactions simulated, additional simulations in a water phantom with tight resolution (1 mm in all directions) were performed with FLUKA. Finally, integral depth-dose distributions for a 250 MeV energy were computed with Geant4 and PENH in a homogeneous phantom with, first, ICRU striated muscle and, second, ICRU compact bone. For simulations with EM collisions only, integral depth-dose distributions were within 1%/1 mm for doses higher than 10% of the Bragg-peak dose. For central-axis depth-dose and lateral profiles in a phantom with tight resolution, there are significant deviations between Geant4 and PENH (up to 60%/1 cm for depth-dose distributions). The agreement is much better with FLUKA, with deviations within 3%/3 mm. When nuclear interactions were turned on, agreement (within 6% before the Bragg-peak) between PENH and Geant4 was consistent with uncertainties on nuclear models and cross sections, whatever the material simulated (water, muscle, or bone). A detailed and flexible description of nuclear reactions has been implemented in the PENH extension of PENELOPE to protons, which utilizes a mixed-simulation scheme for both elastic and inelastic EM collisions, analogous to the well-established algorithm for electrons/positrons. PENH is compatible with all current main programs that use PENELOPE as the MC engine. The nuclear model of PENH is realistic enough to give dose distributions in fair agreement with those computed by Geant4.

  1. Extension of PENELOPE to protons: Simulation of nuclear reactions and benchmark with Geant4

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sterpin, E.; Sorriaux, J.; Vynckier, S.

    2013-11-15

    Purpose: Describing the implementation of nuclear reactions in the extension of the Monte Carlo code (MC) PENELOPE to protons (PENH) and benchmarking with Geant4.Methods: PENH is based on mixed-simulation mechanics for both elastic and inelastic electromagnetic collisions (EM). The adopted differential cross sections for EM elastic collisions are calculated using the eikonal approximation with the Dirac–Hartree–Fock–Slater atomic potential. Cross sections for EM inelastic collisions are computed within the relativistic Born approximation, using the Sternheimer–Liljequist model of the generalized oscillator strength. Nuclear elastic and inelastic collisions were simulated using explicitly the scattering analysis interactive dialin database for {sup 1}H and ICRUmore » 63 data for {sup 12}C, {sup 14}N, {sup 16}O, {sup 31}P, and {sup 40}Ca. Secondary protons, alphas, and deuterons were all simulated as protons, with the energy adapted to ensure consistent range. Prompt gamma emission can also be simulated upon user request. Simulations were performed in a water phantom with nuclear interactions switched off or on and integral depth–dose distributions were compared. Binary-cascade and precompound models were used for Geant4. Initial energies of 100 and 250 MeV were considered. For cases with no nuclear interactions simulated, additional simulations in a water phantom with tight resolution (1 mm in all directions) were performed with FLUKA. Finally, integral depth–dose distributions for a 250 MeV energy were computed with Geant4 and PENH in a homogeneous phantom with, first, ICRU striated muscle and, second, ICRU compact bone.Results: For simulations with EM collisions only, integral depth–dose distributions were within 1%/1 mm for doses higher than 10% of the Bragg-peak dose. For central-axis depth–dose and lateral profiles in a phantom with tight resolution, there are significant deviations between Geant4 and PENH (up to 60%/1 cm for depth–dose distributions). The agreement is much better with FLUKA, with deviations within 3%/3 mm. When nuclear interactions were turned on, agreement (within 6% before the Bragg-peak) between PENH and Geant4 was consistent with uncertainties on nuclear models and cross sections, whatever the material simulated (water, muscle, or bone).Conclusions: A detailed and flexible description of nuclear reactions has been implemented in the PENH extension of PENELOPE to protons, which utilizes a mixed-simulation scheme for both elastic and inelastic EM collisions, analogous to the well-established algorithm for electrons/positrons. PENH is compatible with all current main programs that use PENELOPE as the MC engine. The nuclear model of PENH is realistic enough to give dose distributions in fair agreement with those computed by Geant4.« less

  2. Determination of Small Animal Long Bone Properties Using Densitometry

    NASA Technical Reports Server (NTRS)

    Breit, Gregory A.; Goldberg, BethAnn K.; Whalen, Robert T.; Hargens, Alan R. (Technical Monitor)

    1996-01-01

    Assessment of bone structural property changes due to loading regimens or pharmacological treatment typically requires destructive mechanical testing and sectioning. Our group has accurately and non-destructively estimated three dimensional cross-sectional areal properties (principal moments of inertia, Imax and Imin, and principal angle, Theta) of human cadaver long bones from pixel-by-pixel analysis of three non-coplanar densitometry scans. Because the scanner beam width is on the order of typical small animal diapbyseal diameters, applying this technique to high-resolution scans of rat long bones necessitates additional processing to minimize errors induced by beam smearing, such as dependence on sample orientation and overestimation of Imax and Imin. We hypothesized that these errors are correctable by digital image processing of the raw scan data. In all cases, four scans, using only the low energy data (Hologic QDR-1000W, small animal mode), are averaged to increase image signal-to-noise ratio. Raw scans are additionally processed by interpolation, deconvolution by a filter derived from scanner beam characteristics, and masking using a variable threshold based on image dynamic range. To assess accuracy, we scanned an aluminum step phantom at 12 orientations over a range of 180 deg about the longitudinal axis, in 15 deg increments. The phantom dimensions (2.5, 3.1, 3.8 mm x 4.4 mm; Imin/Imax: 0.33-0.74) were comparable to the dimensions of a rat femur which was also scanned. Cross-sectional properties were determined at 0.25 mm increments along the length of the phantom and femur. The table shows average error (+/- SD) from theory of Imax, Imin, and Theta) over the 12 orientations, calculated from raw and fully processed phantom images, as well as standard deviations about the mean for the femur scans. Processing of phantom scans increased agreement with theory, indicating improved accuracy. Smaller standard deviations with processing indicate increased precision and repeatability. Standard deviations for the femur are consistent with those of the phantom. We conclude that in conjunction with digital image enhancement, densitometry scans are suitable for non-destructive determination of areal properties of small animal bones of comparable size to our phantom, allowing prediction of Imax and Imin within 2.5% and Theta within a fraction of a degree. This method represents a considerable extension of current methods of analyzing bone tissue distribution in small animal bones.

  3. Prevalence of masked uncontrolled hypertension according to the number of office blood pressure measurements.

    PubMed

    Vinyoles, E; Camafort, M; Domenech, M; Coca, A; Sobrino, J

    2015-11-01

    The reported prevalence of masked uncontrolled hypertension (MUCH) varies because many studies are not comparable as they use different measurement methodologies. To evaluate the influence of the number of office blood pressure readings on the prevalence of MUCH we conducted a cross-sectional, multicenter study in treated hypertensive patients. We carried out an observational, cross-sectional, multicenter study in 33 Spanish hospital-based hypertension units, involving 35 investigators and 12 Autonomous Communities. Six blood pressure readings and a 24-h ambulatory blood pressure monitoring were performed in treated hypertensive patients. The means of the first 3 readings (P123), the 2nd, 3rd and 4th readings (P234), the 3rd, 4th and 5th readings (P345) and the last 3 readings (P456) were compared with mean 24-h blood pressure. MUCH was defined as office blood pressure <140/90mmHg and 24-h blood pressure ≥130/80mmHg, considering the first 3 readings (MUCH123), the 2nd, 3rd and 4th readings (MUCH234), the 3rd, 4th and 5th readings (MUCH345) and the last 3 readings (MUCH456). We included 498 hypertensive patients. Mean (standard deviation) office blood pressure measurements were: (P123) 141(18)/82(11); (P234) 139(17)/81(11); (P345) 138(17)/81(11) and (P456) 137(16)/80(10) mmHg. Mean 24-h blood pressure was 127(13.8)/75(9.5) mmHg. The correlation coefficients between ambulatory and office systolic/diastolic blood pressure were (P123):0.48/0.50; (P234):0.50/0.52; (P345):0.50/0.54; and (P456):0.50/0.55 (p<0.001, all). The prevalences of MUCH123, MUCH234, MUCH345 and MUCH456 were 14.5%, 18.9%, 19.5% and 21.1%, respectively. The prevalence of MUCH diagnosis depends on the serial office blood pressure readings, being much higher for the last three blood pressure readings. Discarding the first and second office blood pressure measures seems to be the most accurate method for diagnosing MUCH. Copyright © 2015 Elsevier España, S.L.U. y Sociedad Española de Medicina Interna (SEMI). All rights reserved.

  4. Experimental investigation of the two-phase flow regimes and pressure drop in horizontal mini-size rectangular test section

    NASA Astrophysics Data System (ADS)

    Elazhary, Amr Mohamed; Soliman, Hassan M.

    2012-10-01

    An experimental study was conducted in order to investigate two-phase flow regimes and fully developed pressure drop in a mini-size, horizontal rectangular channel. The test section was machined in the form of an impacting tee junction in an acrylic block (in order to facilitate visualization) with a rectangular cross-section of 1.87-mm height on 20-mm width on the inlet and outlet sides. Pressure drop measurement and flow regime identification were performed on all three sides of the junction. Air-water mixtures at 200 kPa (abs) and room temperature were used as the test fluids. Four flow regimes were identified visually: bubbly, plug, churn, and annular over the ranges of gas and liquid superficial velocities of 0.04 ≤ JG ≤ 10 m/s and 0.02 ≤ JL ≤ 0.7 m/s, respectively, and a flow regime map was developed. Accuracy of the pressure-measurement technique was validated with single-phase, laminar and turbulent, fully developed data. Two-phase experiments were conducted for eight different inlet conditions and various mass splits at the junction. Comparisons were conducted between the present data and former correlations for the fully developed two-phase pressure drop in rectangular channels with similar sizes. Wide deviations were found among these correlations, and the correlations that agreed best with the present data were identified.

  5. Measurement of the percentage of root filling in oval-shaped canals obturated with Thermafil Obturators and Beefill 2in1: In vitro study

    PubMed Central

    Collado-Castellanos, Nicolás; Alegre-Domingo, Teresa; Dolz-Solsona, María; Faus-Matoses, Vicente

    2015-01-01

    Background The aim of the study was to measure the percentage of root canal fillings in long oval canals obturated with thermoplasticized gutta-percha techniques, Beefill 2in1® and Thermafil Obturators®. Material and Methods Fifty four mandibular incisors were selected after bucco-lingual and mesio-distal radiographs showed at 5 mm from apex an internal long:short diameter ≥2. Teeth were instrumented with Protaper Universal and divided in two groups of 27. Group 1 was obturated with Thermafil Obturators® and group 2 with Beefill 2in1®. Two horizontal sections were cut at 5 and 7 mm from the apex and photographed in a stereo-microscope. The total area of the canal and filled canal in cross-sections were measured with AutoCad and the percentages of gutta-percha-sealer and voids in the canal were obtained. Results Both systems achieved high percentage of filled canal, Thermafil 96.8% and Beefill 2in1 98.9%. The percentages of voids in both groups were very low. No significant differences were found between the two groups . The percentage obtained at 5 and 7 mm from the apex in both groups showed no significant difference. Conclusions The percentages of filled canal (gutta-percha-sealer) were high and these two thermoplasticized techniques are suitable for long oval canals obturation. Key words:Long oval canal, oval canal, thermoplasticized obturation. PMID:26155350

  6. Measurement of the percentage of root filling in oval-shaped canals obturated with Thermafil Obturators and Beefill 2in1: In vitro study.

    PubMed

    Faus-Llácer, Vicente; Collado-Castellanos, Nicolás; Alegre-Domingo, Teresa; Dolz-Solsona, María; Faus-Matoses, Vicente

    2015-04-01

    The aim of the study was to measure the percentage of root canal fillings in long oval canals obturated with thermoplasticized gutta-percha techniques, Beefill 2in1® and Thermafil Obturators®. Fifty four mandibular incisors were selected after bucco-lingual and mesio-distal radiographs showed at 5 mm from apex an internal long:short diameter ≥2. Teeth were instrumented with Protaper Universal and divided in two groups of 27. Group 1 was obturated with Thermafil Obturators® and group 2 with Beefill 2in1®. Two horizontal sections were cut at 5 and 7 mm from the apex and photographed in a stereo-microscope. The total area of the canal and filled canal in cross-sections were measured with AutoCad and the percentages of gutta-percha-sealer and voids in the canal were obtained. Both systems achieved high percentage of filled canal, Thermafil 96.8% and Beefill 2in1 98.9%. The percentages of voids in both groups were very low. No significant differences were found between the two groups . The percentage obtained at 5 and 7 mm from the apex in both groups showed no significant difference. The percentages of filled canal (gutta-percha-sealer) were high and these two thermoplasticized techniques are suitable for long oval canals obturation. Key words:Long oval canal, oval canal, thermoplasticized obturation.

  7. PIT-tagged particle study of bed mobility in a Maine salmon river impacted by logging activities

    NASA Astrophysics Data System (ADS)

    Thompson, D. M.; Fixler, S. A.; Roberts, K. E.; McKenna, M.; Marshall, A. E.; Koenig, S.

    2017-12-01

    Presenting an interim report on a study on the Narraguagus River in Maine, which utilizes laser total stations cross-sectional surveys and tracking of passive integrated transponder (PIT) tags embedded in glass spheres to document changes in channel-bed characteristics associated with large wood (LW) additions and natural spawning activities. In 2016, work was initiated to monitor changes in bed elevation and sediment mobility with the addition of LW to the Narraguagus River as part of a restoration effort. Ten cross-sections, spaced 5-m apart, were established and surveyed with a laser total station in each of three different study reaches. The study sites include a control reach, a section with anticipated spawning activities and a site with ongoing LW placement. A grid of 200 glass spheres embedded with PIT tags, with twenty alternating 25-mm and 40-mm size particles equally spaced along each of the ten transects, were placed to serve as point sensors to detect sediment mobilization within each reach. In 2017, the site was revisited to determine if differences in PIT-tagged tracer particle mobilization reflect locations were LW was added and places where Atlantic salmon (Salmo salar) and sea lamprey (Petromyzon marinus) construct spawning redds. The positions of PIT-tagged tracer particles was recorded, but particles were not disturbed or uncovered to permit study of potential reworking of buried tracer particles the following year. Full tracer particle recovery will be determined in 2018 to determine if depths of tracer burial and changes in bed elevation vary among places near redds, LW and main channel locations. The data will be used to determine if salmon redds are preferentially located in either places with greater evidence of sediment reworking or alternatively in stable areas? The study will help determine the degree of bed disruption associated with spawning activities and whether LW placement encourages similar sediment mobilization processes.

  8. Effects of hillslope gully stabilization on erosion and sediment production in the Torreon Wash watershed, New Mexico, 2009–12

    USGS Publications Warehouse

    Matherne, Anne Marie; Tillery, Anne C.; Douglas-Mankin, Kyle R.

    2018-04-10

    Sediment erosion and deposition in two sets of paired (treated and untreated) upland drainages in the Torreon Wash watershed, upper Rio Puerco Basin, New Mexico, were examined over a 3 1/2-year period from spring 2009 through fall 2012. The objective was to evaluate the effectiveness of shallow, loose-stone check dams, or “one-rock dams,” as a hillslope gully erosion stabilization and mitigation method, and its potential for retaining upland eroded soils and decreasing delivery of sediment to lower ephemeral stream channels. Two high-resolution topographic surveys, completed at the beginning and end of the study period, were used to assess the effects of the mitigation measures at paired-drainage sites in both Penistaja Arroyo and Papers Wash watersheds, and at six main-stem-channel cross-section clusters along Penistaja Arroyo and Torreon Wash in the Torreon Wash watershed.For both drainage pairs, the treated drainage had greater sediment aggradation near the channel than the untreated drainage. Erosion was the dominant geomorphic process in the untreated Penistaja Arroyo drainage, whereas aggradation was the dominant process in the other three drainages. For the Penistaja Arroyo paired drainages, the treated site showed a 51-percent increase in area aggraded and 67-percent increase in volume aggraded per area analyzed over the untreated site. Both Papers Wash drainages showed net aggradation, but with similar treatment effect, with the treated site showing a 29-percent increase in area aggraded and 60-percent increase in volume aggraded per area analyzed over the untreated site. In the untreated Penistaja Arroyo drainage, the calculated minimum erosion rate was 0.0055 inches per year (in/yr; 0.14 millimeters per year [mm/yr]), whereas the calculated aggradation rates for the three drainages for which aggradation was the dominant geomorphic process were 0.0063 in/yr (0.16 mm/yr) for the Penistaja Arroyo treated drainage, 0.012 in/yr (0.31 mm/yr) for the Papers Wash untreated drainage, and 0.988 in/yr (2.51 mm/yr) for the Papers Wash treated drainage.Changes in the channel cross section along the main-stem Penistaja Arroyo and Torreon Wash were also examined. Channel-bank slumping and erosion of previously deposited bed material were apparent sources for sediment suspended in ephemeral streamflow. Cross-sectional channel surveys indicated examples of both erosion and deposition along each channel over the study period. Because the drainage area of the treated drainages is small compared to that of the Torreon Wash watershed, the upland mitigation measures would not be expected to measurably affect short-term concentrations of suspended sediment in main-stem channels.One-rock-dam mitigation structures in the upland drainages appear to have resulted in a decrease in sediment delivery to the main-stem channel. One-rock-dam mitigation structures may affect streamflow through their influence on runoff volume (via infiltration) and runoff rate (via detention), both of which may vary with time after structure installation.

  9. The Effect of Annealing on the Elastic Modulus of Orthodontic Wires

    NASA Astrophysics Data System (ADS)

    Higginbottom, Kyle

    Introduction: Nickel Titanium orthodontic wires are currently used in orthodontic treatment due to their heat activated properties and their delivery of constant force. The objective of this study was to determine the effect of annealing on the elastic modulus of Nickel Titanium, Stainless Steel and Beta-titanium (TMA) wires. Different points along the wire were tested in order to determine how far from the annealed ends the elastic modulus of the wires was affected. Methods: Eighty (80) orthodontic wires consisting of 4 equal groups (SS/TMA/Classic NitinolRTM/Super Elastic NitinolRTM) were used as the specimens for this study. All wires were measured and marked at 5mm measurements, and cut into 33.00mm sections. The wires were heated with a butane torch until the first 13.00mm of the wires were red hot. Load deflection tests using an InstronRTM universal testing machine were run at 5mm distances from the end of the wire that had been annealed. The change in elastic modulus was then determined. Results: There was a significant difference (F = 533.001, p = 0.0005) in the change in elastic modulus for the four distances. There was also a significant difference (F = 57.571, p = 0.0005) in the change in elastic modulus for the four wire types. There was a significant interaction (F = 19.601, p = 0.005) between wire type and distance, however this interaction negated the differences between the wires. Conclusion: 1) There are significant differences in the changes in elastic modulus between the areas of the wires within the annealed section and those areas 5mm and 10mm away from the annealed section. The change in elastic modulus within the annealed section was significantly greater at 8 mm than it was at 13mm, and this was significantly greater than 18mm and 23mm (5mm and 10mm beyond the annealed section). However, there was no statistical difference in the change in elastic modulus between 5mm and 10mm away from the annealed section (18mm and 23mm respectively). 2) Regardless of the wire type, no clinically important effects were seen 5mm and 10mm beyond the annealed portion.

  10. SU-C-BRC-06: OpenCL-Based Cross-Platform Monte Carlo Simulation Package for Carbon Ion Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qin, N; Tian, Z; Pompos, A

    2016-06-15

    Purpose: Monte Carlo (MC) simulation is considered to be the most accurate method for calculation of absorbed dose and fundamental physical quantities related to biological effects in carbon ion therapy. Its long computation time impedes clinical and research applications. We have developed an MC package, goCMC, on parallel processing platforms, aiming at achieving accurate and efficient simulations for carbon therapy. Methods: goCMC was developed under OpenCL framework. It supported transport simulation in voxelized geometry with kinetic energy up to 450 MeV/u. Class II condensed history algorithm was employed for charged particle transport with stopping power computed via Bethe-Bloch equation. Secondarymore » electrons were not transported with their energy locally deposited. Energy straggling and multiple scattering were modeled. Production of secondary charged particles from nuclear interactions was implemented based on cross section and yield data from Geant4. They were transported via the condensed history scheme. goCMC supported scoring various quantities of interest e.g. physical dose, particle fluence, spectrum, linear energy transfer, and positron emitting nuclei. Results: goCMC has been benchmarked against Geant4 with different phantoms and beam energies. For 100 MeV/u, 250 MeV/u and 400 MeV/u beams impinging to a water phantom, range difference was 0.03 mm, 0.20 mm and 0.53 mm, and mean dose difference was 0.47%, 0.72% and 0.79%, respectively. goCMC can run on various computing devices. Depending on the beam energy and voxel size, it took 20∼100 seconds to simulate 10{sup 7} carbons on an AMD Radeon GPU card. The corresponding CPU time for Geant4 with the same setup was 60∼100 hours. Conclusion: We have developed an OpenCL-based cross-platform carbon MC simulation package, goCMC. Its accuracy, efficiency and portability make goCMC attractive for research and clinical applications in carbon therapy.« less

  11. Biometric study of the internal dimensions of subglottis and upper trachea in adult Indian population.

    PubMed

    Prasanna Kumar, S; Ravikumar, A

    2014-01-01

    The anatomy of the larynx and trachea is well described in literature, however the intraluminal dimensions and contour of the subglottis has not been well documented. Subglottis and trachea are dynamic structures and the internal dimensions and contours have been studied only on cadavers or by plain radiograph which has many technical and measurement errors. No data is available about the internal dimensions of the subglottic and trachea in Indian population. This is the first documented study to measure the dimensions of the trachea and subglottis in Indian population. The aim of this study is to measure the internal dimensions and contour of the subglottis and upper trachea of adult Indian population. We conducted cross-sectional, observational study in a university hospital in south India to measure the dimensions of the internal subglottic and upper tracheal lumen. CT scan with 3D reconstruction with multiplanar sections was used for precise measurements. Forty-eight subjects (30 male and 18 female) who had undergone CT scan of the neck and thorax for reasons other than airway compromise were included in the study. The internal coronal diameter (CD), sagittal diameter (SD), and circumference was measured at various levels from 5 to 70 mm below the level of glottis, in the subglottis and upper trachea. Measurements of the scan for each subject were done independently by a radiologist and ENT surgeon and average of the two were documented values of each subject. These measurements were then statistically analyzed using SSPS software. The mean CD of adult Indian male ranged from 13.18 to 17.68 mm. The average intraluminal circumference ranged from 48.82 mm at the subglottis 5 mm from the glottis to a maximum of 54.96 at 30 mm. The mean CD of adult Indian female ranged from 8.7 to 15.34 mm The average intraluminal circumference ranged from 36.5 at 5 mm and a maximum of 43.05 at 70 mm. The 95% CI for the coronal, sagittal and circumference of the subglottis and upper trachea for both genders have been calculated and discussed. We have observed that the average intraluminal dimensions of the subglottis and upper trachea in south Indian population is less than that reported in western literature and earlier studies.

  12. Comparison of 3-D Multi-Lag Cross-Correlation and Speckle Brightness Aberration Correction Algorithms on Static and Moving Targets

    PubMed Central

    Ivancevich, Nikolas M.; Dahl, Jeremy J.; Smith, Stephen W.

    2010-01-01

    Phase correction has the potential to increase the image quality of 3-D ultrasound, especially transcranial ultrasound. We implemented and compared 2 algorithms for aberration correction, multi-lag cross-correlation and speckle brightness, using static and moving targets. We corrected three 75-ns rms electronic aberrators with full-width at half-maximum (FWHM) auto-correlation lengths of 1.35, 2.7, and 5.4 mm. Cross-correlation proved the better algorithm at 2.7 and 5.4 mm correlation lengths (P < 0.05). Static cross-correlation performed better than moving-target cross-correlation at the 2.7 mm correlation length (P < 0.05). Finally, we compared the static and moving-target cross-correlation on a flow phantom with a skull casting aberrator. Using signal from static targets, the correction resulted in an average contrast increase of 22.2%, compared with 13.2% using signal from moving targets. The contrast-to-noise ratio (CNR) increased by 20.5% and 12.8% using static and moving targets, respectively. Doppler signal strength increased by 5.6% and 4.9% for the static and moving-targets methods, respectively. PMID:19942503

  13. Comparison of 3-D multi-lag cross- correlation and speckle brightness aberration correction algorithms on static and moving targets.

    PubMed

    Ivancevich, Nikolas M; Dahl, Jeremy J; Smith, Stephen W

    2009-10-01

    Phase correction has the potential to increase the image quality of 3-D ultrasound, especially transcranial ultrasound. We implemented and compared 2 algorithms for aberration correction, multi-lag cross-correlation and speckle brightness, using static and moving targets. We corrected three 75-ns rms electronic aberrators with full-width at half-maximum (FWHM) auto-correlation lengths of 1.35, 2.7, and 5.4 mm. Cross-correlation proved the better algorithm at 2.7 and 5.4 mm correlation lengths (P < 0.05). Static cross-correlation performed better than moving-target cross-correlation at the 2.7 mm correlation length (P < 0.05). Finally, we compared the static and moving-target cross-correlation on a flow phantom with a skull casting aberrator. Using signal from static targets, the correction resulted in an average contrast increase of 22.2%, compared with 13.2% using signal from moving targets. The contrast-to-noise ratio (CNR) increased by 20.5% and 12.8% using static and moving targets, respectively. Doppler signal strength increased by 5.6% and 4.9% for the static and moving-targets methods, respectively.

  14. Esophagogastric junction distensibility measurements during Heller myotomy and POEM for achalasia predict postoperative symptomatic outcomes

    PubMed Central

    Teitelbaum, Ezra N.; Soper, Nathaniel J.; Pandolfino, John E.; Kahrilas, Peter J.; Hirano, Ikuo; Boris, Lubomyr; Nicodème, Frédéric; Lin, Zhiyue; Hungness, Eric S.

    2015-01-01

    Background The functional lumen imaging probe (FLIP) is a novel diagnostic tool that can be used to measure esophagogastric junction (EGJ) distensibility. In this study we performed intraoperative FLIP measurements during laparoscopic Heller myotomy (LHM) and peroral esophageal myotomy (POEM) for treatment of achalasia and evaluated the relationship between EGJ distensibility and postoperative symptoms. Methods Distensibility index (DI) (defined as the minimum cross-sectional area at the EGJ divided by distensive pressure) was measured with FLIP at two time points during LHM and POEM: 1) at baseline after induction of anesthesia, and 2) after operation completion. Results Measurements were performed in 20 patients undergoing LHM and 36 undergoing POEM. Both operations resulted in an increase in DI, although this increase was larger with POEM (7±3.1 vs. 5.1±3.4mm2/mmHg, p<.05). The two patients (both LHM) with the smallest increases in DI (1 and 1.6mm2/mmHg) both had persistent symptoms postoperatively and, overall, LHM patients with larger increases in DI had lower postoperative Eckardt scores. In the POEM group, there was no correlation between change in DI and symptoms; however, all POEM patients experienced an increase in DI of >3mm2/mmHg. When all patients were divided into thirds based on final DI, none in the lowest DI group (<6mm2/mmHg) had symptoms suggestive of reflux (i.e., GerdQ score >7), as compared with 20% in the middle third (6–9mm2/mmHg) and 36% in the highest third (>9mm2/mmHg). Patients within an “ideal” final DI range (4.5–8.5 mm2/mmHg) had optimal symptomatic outcomes (i.e. Eckardt≤1 and GerdQ≤7) in 88% of cases, compared with 47% in those with a final DI above or below that range (p<.05). Conclusions Intraoperative EGJ distensibility measurements with FLIP were predictive of postoperative symptomatic outcomes. These results provide initial evidence that FLIP has the potential to act as a useful calibration tool during operations for achalasia. PMID:25055891

  15. Influence of fine threads and platform-switching on crestal bone stress around implant-a three-dimensional finite element analysis.

    PubMed

    Khurana, Pardeep; Sharma, Arun; Sodhi, Kiranmeet Kaur

    2013-12-01

    The aims of this study were to investigate the effect of implant fine threads on crestal bone stress compared to a standard smooth implant collar and to analyze how different abutment diameters influenced the crestal bone stress level. Three-dimensional finite element imaging was used to create a cross-sectional model in SolidWorks 2007 software of an implant (5-mm platform and 10 mm in length) placed in the premolar region of the mandible. The implant model was created to resemble a commercially available fine thread implant. Abutments of different diameters (5.0 mm: standard, 4.5 mm, 4.0 mm, and 3.5 mm) were loaded with a force of 100 N at 90° vertical and 40° oblique angles. Finite element analysis was done in COSMOSWorks software, which was used to analyze the stress patterns in bone, especially in the crestal region. Upon loading, the fine thread implant model had greater stress at the crestal bone adjacent to the implant than the smooth neck implant in both vertical and oblique loading. When the abutment diameter decreased progressively from 5.0 mm to 4.5 mm to 4 mm and to 3.5 mm the thread model showed a reduction of stress at the crestal bone level from 23.2 MPa to 15.02 MPa for fine thread and from 22.7 to 13.5 MPa for smooth collar implant group after vertical loading and from 43.7 MPa to 33.1 MPa in fine thread model and from 36.9 to 20.5 MPa in smooth collar implant model after oblique loading. Fine threads increase crestal stress upon loading. Reduced abutment diameter that is platform switching resulted in less stress translated to the crestal bone in the fine thread and smooth neck.

  16. MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging

    NASA Astrophysics Data System (ADS)

    Tai, Yuan-Chuan; Chatziioannou, Arion F.; Yang, Yongfeng; Silverman, Robert W.; Meadors, Ken; Siegel, Stefan; Newport, Danny F.; Stickel, Jennifer R.; Cherry, Simon R.

    2003-06-01

    MicroPET II is a second-generation animal PET scanner designed for high-resolution imaging of small laboratory rodents. The system consists of 90 scintillation detector modules arranged in three contiguous axial rings with a ring diameter of 16.0 cm and an axial length of 4.9 cm. Each detector module consists of a 14 × 14 array of lutetium oxyorthosilicate (LSO) crystals coupled to a multi-channel photomultiplier tube (MC-PMT) through a coherent optical fibre bundle. Each LSO crystal element measures 0.975 mm × 0.975 mm in cross section by 12.5 mm in length. A barium sulphate reflector material was used between LSO elements leading to a detector pitch of 1.15 mm in both axial and transverse directions. Fused optical fibre bundles were made from 90 µm diameter glass fibres with a numerical aperture of 0.56. Interstitial extramural absorber was added between the fibres to reduce optical cross talk. A charge-division readout circuit was implemented on printed circuit boards to decode the 196 crystals in each array from the outputs of the 64 anode signals of the MC-PMT. Electronics from Concorde Microsystems Inc. (Knoxville, TN) were used for signal amplification, digitization, event qualification, coincidence processing and data capture. Coincidence data were passed to a host PC that recorded events in list mode. Following acquisition, data were sorted into sinograms and reconstructed using Fourier rebinning and filtered backprojection algorithms. Basic evaluation of the system has been completed. The absolute sensitivity of the microPET II scanner was 2.26% at the centre of the field of view (CFOV) for an energy window of 250-750 keV and a timing window of 10 ns. The intrinsic spatial resolution of the detectors in the system averaged 1.21 mm full width at half maximum (FWHM) when measured with a 22Na point source 0.5 mm in diameter. Reconstructed image resolution ranged from 0.83 mm FWHM at the CFOV to 1.47 mm FWHM in the radial direction, 1.17 mm FWHM in the tangential direction and 1.42 mm FWHM in the axial direction at 1 cm offset from the CFOV. These values represent highly significant improvements over our earlier microPET scanner (approximately fourfold sensitivity increase and 25-35% improvement in linear spatial resolution under equivalent operating conditions) and are expected to be further improved when the system is fully optimized. This work was originally conducted at UCLA, Crump Institute for Molecular Imaging, and was continued and completed at UC Davis, Department of Biomedical Engineering.

  17. Comparison of histologic margin status in low-grade cutaneous and subcutaneous canine mast cell tumours examined by radial and tangential sections.

    PubMed

    Dores, C B; Milovancev, M; Russell, D S

    2018-03-01

    Radial sections are widely used to estimate adequacy of excision in canine cutaneous mast cell tumours (MCTs); however, this sectioning technique estimates only a small fraction of total margin circumference. This study aimed to compare histologic margin status in grade II/low grade MCTs sectioned using both radial and tangential sectioning techniques. A total of 43 circumferential margins were evaluated from 21 different tumours. Margins were first sectioned radially, followed by tangential sections. Tissues were examined by routine histopathology. Tangential margin status differed in 10 of 43 (23.3%) margins compared with their initial status on radial section. Of 39 margins, 9 (23.1%) categorized as histologic tumour-free margin (HTFM) >0 mm were positive on tangential sectioning. Tangential sections detected a significantly higher proportion of positive margins relative to radial sections (exact 2-tailed P-value = .0215). The HTFM was significantly longer in negative tangential margins than positive tangential margins (mean 10.1 vs 3.2 mm; P = .0008). A receiver operating characteristic curve comparing HTFM and tangentially negative margins found an area under the curve of 0.83 (95% confidence interval: 0.71-0.96). Although correct classification peaked at the sixth cut-point of HTFM ≥1 mm, radial sections still incorrectly classified 50% of margins as lacking tumour cells. Radial sections had 100% specificity for predicting negative tangential margins at a cut-point of 10.9 mm. These data indicate that for low grade MCTs, HTFMs >0 mm should not be considered completely excised, particularly when HTFM is <10.9 mm. This will inform future studies that use HTFM and overall excisional status as dependent variables in multivariable prognostic models. © 2017 John Wiley & Sons Ltd.

  18. Position and time resolution measurements with a microchannel plate image intensifier: A comparison of monolithic and pixelated CeBr3 scintillators

    NASA Astrophysics Data System (ADS)

    Ackermann, Ulrich; Eschbaumer, Stephan; Bergmaier, Andreas; Egger, Werner; Sperr, Peter; Greubel, Christoph; Löwe, Benjamin; Schotanus, Paul; Dollinger, Günther

    2016-07-01

    To perform Four Dimensional Age Momentum Correlation measurements in the near future, where one obtains the positron lifetime in coincidence with the three dimensional momentum of the electron annihilating with the positron, we have investigated the time and position resolution of two CeBr3 scintillators (monolithic and an array of pixels) using a Photek IPD340/Q/BI/RS microchannel plate image intensifier. The microchannel plate image intensifier has an active diameter of 40 mm and a stack of two microchannel plates in chevron configuration. The monolithic CeBr3 scintillator was cylindrically shaped with a diameter of 40 mm and a height of 5 mm. The pixelated scintillator array covered the whole active area of the microchannel plate image intensifier and the shape of each pixel was 2.5·2.5·8 mm3 with a pixel pitch of 3.3 mm. For the monolithic setup the measured mean single time resolution was 330 ps (FWHM) at a gamma energy of 511 keV. No significant dependence on the position was detected. The position resolution at the center of the monolithic scintillator was about 2.5 mm (FWHM) at a gamma energy of 662 keV. The single time resolution of the pixelated crystal setup reached 320 ps (FWHM) in the region of the center of the active area of the microchannel plate image intensifier. The position resolution was limited by the cross-section of the pixels. The gamma energy for the pixel setup measurements was 511 keV.

  19. [Effects of irrigation amount on morphological characteristics and water use of Jatropha curcas].

    PubMed

    Yang, Qi-Liang; Zhang, Jing; Liu, Xiao-Gang; Liu, Yan-Wei; Yang, Ju-Rui

    2014-05-01

    Jatropha curcas is the most promising energy tree, and soil moisture is the key factor which affects the seedling quality and water use efficiency of J. curcas. With aims to evaluate the effect of different irrigation amount on growth, morphological characteristics and water use of J. curcas, a pot experiment was conducted with four irrigation amounts, i. e., W1:472.49 mm, W2: 228.79 mm, W3:154.18 mm and W4:106.93 mm, respectively. Compared with W1 treatment, the leaf area and stem cross-section area of base significantly decreased in W2, W3 and W4 treatments, but Huber value significantly increased, which could improve the efficiency of water transfer from root to shoot, thus enhance the capability of resistance to drought stress. Compared with W, treatment, the healthy index of J. curcas seedlings decreased slightly in W2 treatment but significantly decreased in W3 and W4 treatments. Hence, the irrigation amount from 228.79 to 472.49 mm was beneficial to increase the healthy index of J. curcas seedlings. Compared with W1 treatment, irrigation water was saved by 67.4% in W3 treatment, and the total dry mass and evapotranspiration significantly decreased by 17.4% and 68.6%, and the irrigation water use efficiency and total water use efficiency increased by 153.2% and 163.2%, respectively. In the condition of this study, the irrigation amount of 154.18 mm was beneficial to increase water use efficiency.

  20. Treatment of dentinal tubules by Nd:YAG laser

    NASA Astrophysics Data System (ADS)

    Chmelíčkova, Hana; Zapletalova, Zdeňka; Peřina, Jan, Jr.; Novotný, Radko; Kubínek, Roman; Stranyánek, Martin

    2005-08-01

    Symptom of cervical dentine hypersensitivity attacks from 10% to 15% of population and causes an uncomfortable pain during contact with any matter. Sealing of open dentinal tubules is one of the methods to reach insensibility. Laser as a source of coherent radiation is used to melt dentine surface layers. Melted dentine turns to hard mass with a smooth, non-porous surface. Simulation of this therapy was made in vitro by means of LASAG Nd:YAG pulsed laser system KLS 246-102. Eighty human extracted teeth were cut horizontally to obtain samples from 2 mm to 3 mm thick. First experiments were done on cross section surfaces to find an optimal range of laser parameters. A wide range of energies from 30 mJ to 210 mJ embedded in 0,3 ms long pulse was tested. Motion in X and Y axes was ensured by a CNC driven table and the pulse frequency 15 Hz was chosen to have a suitable overlap of laser spots. Some color agents were examined with the aim to improve surface absorption. Scanning Electron Microscopy was used to evaluate all samples and provided optimal values of energies around 50 J.cm-2. Next experiments were done with the beam oriented perpendicularly to a root surface, close to the real situation. Optical fibers with the diameter of 0,6 mm and 0,2 mm were used to guide a laser beam to teeth surfaces. Laser processing heads with lens F = 100 mm and F = 50 mm were used. The best samples were investigated by means of the Atomic Force Microscopy.

  1. Oral health status and alveolar bone loss in treated leprosy patients of central India.

    PubMed

    Rawlani, S M; Rawlani, S; Degwekar, S; Bhowte, R R; Motwani, M

    2011-01-01

    A descriptive cross sectional study was carried out, in a group of 160 leprosy patients treated with multi drug therapy. The patients with age group of 25 to 60 year were considered. Out of 160 patients 50 patients were selected by simple random sampling technique for radiological assessments. Intra-oral periapical radiographs (6 for each patient) were taken. The paralleling long cone technique was used and radiographs were attached with grids so as to enable measuring the bone height. The grid was spaced in 1 mm marking and placed directly over the film. Clinical examination revealed that Prevalence of dental caries was 76.25% and periodontal disease was 78.75%. Mean DMFT score was 2.26. Mean OHI-S score was 3.50. Score for Gingival index was 1.60 and average loss of gingival attachment was 1.2 mm. Radiographic findings showed mean alveolar bone loss in maxillary anterior region to be 5.05 mm and in maxillary posterior region it was 4.92 mm. Alveolar bone loss in mandibular anterior region was 4.35 mm and in mandibular posterior region was 5.14 mm. Overall Dental Health Status of the leprosy patients was poor and needed more attention for dental care. There was also an increase in the alveolar bone loss, which was generalized. This bone loss could be due to advance stage of the disease or late approach to rehabilitation center, these patients also had peripheral neuropathy leading to hand and feet deformity in the form of claw hand or ulcer on hand, making maintenance of oral hygiene difficult.

  2. Dialysis Amyloid Deposition in the Aortic Valve and Its Association with Aortic Stenosis.

    PubMed

    Kurita, Noriaki; Fujii, Akiko; Kotera, Nagaaki; Tanaka, Mototsugu; Tanaka, Shinji; Miyairi, Takeshi; Sugimoto, Tokuichiro; Mori, Masaya; Fukuhara, Shunichi; Mise, Naobumi

    2015-01-01

    The relationship between dialysis amyloid (DA) deposition in the aortic valve (AV) and aortic stenosis (AS) is unknown. This was a cross-sectional study. AV specimens of dialysis patients (median vintage: 8.8 years) consecutively collected from cardiac surgeries (n = 56) or autopsies (n = 13) were examined by a board-certified pathologist blinded to clinical data. DAs were considered to be present if deposits were stained both by Congo red with apple-green birefringence under polarized light and by anti-β2-microblobulin antibody. Degree of deposition was graded as follows: Amyloid (-), no deposit; Amyloid (1+), occasional small deposits; Amyloid (2+), multiple small to large deposits or a single large deposit. Calcification was defined as a calcified deposit with a diameter >1 mm in the specimen. Severe AS (sAS) was defined as a mean gradient >50 mm Hg by echocardiogram. We examined the proportion of DAs and the association between DAs and the sAS. DAs were present in 71% (n = 49) of specimens and primarily co-localized with calcification. Non-dialysis related amyloid was found in one specimen. After excluding this specimen, sAS was associated with ‘Amyloid (1+) and Calcification >1 mm' and ‘Amyloid (2+) and Calcification >1 mm' (vs. ‘Amyloid (-) and Calcification ≤1 mm', odds ratios (ORs): 13.5 and 34.2, respectively). Furthermore, after adjustment for covariates, sAS was found to be associated with ‘Amyloid (2+) and Calcification >1 mm' (OR: 24.3). DA deposition in the AV was prevalent among dialysis patients. DA deposition with accompanying calcification might contribute to the severity of AS.

  3. Intra-abdominal fat accumulation is a hypertension risk factor in young adulthood: A cross-sectional study.

    PubMed

    Takeoka, Atsushi; Tayama, Jun; Yamasaki, Hironori; Kobayashi, Masakazu; Ogawa, Sayaka; Saigo, Tatsuo; Kawano, Hiroaki; Abiru, Norio; Hayashida, Masaki; Maeda, Takahiro; Shirabe, Susumu

    2016-11-01

    Accumulation of intra-abdominal fat is related to hypertension. Despite this, a relationship between hypertension and intra-abdominal fat in young adulthood is not clear. In this study, we verify whether intra-abdominal fat accumulation increases a hypertension risk in young adult subjects.In a cross-sectional study, intra-abdominal fat area was measured using a dual bioelectrical impedance analysis instrument in 697 university students (20.3 ± 0.7 years, 425 men). Blood pressure and anthropometric factors were measured. Lifestyle variables including smoking, drinking, physical activity, and eating behavior were assessed with questionnaire. High blood pressure risk (systolic blood pressure ≥130 mm Hg and/or diastolic blood pressure ≥85 mm Hg) with increasing intra-abdominal fat area was evaluated.Participants were divided into 5 groups according to their intra-abdominal fat area (≤24.9, 25-49.9, 50-74.9, 75-99.9, and ≥100 cm). As compared with the values of the smallest intra-abdominal fat area group, the crude and lifestyle-adjusted odds ratios (ORs) were elevated in larger intra-abdominal fat area groups [OR 1.31, 95% confidence interval (CI) 0.66-2.80; OR 3.38, 95% CI 1.60-7.57; OR 7.71, 95% CI 2.75-22.22; OR 18.74, 95% CI 3.93-105.64, respectively). The risk increase was observed only in men.Intra-abdominal fat accumulation is related to high blood pressure in men around 20 years of age. These results indicate the importance of evaluation and reduction of intra-abdominal fat to prevent hypertension.

  4. Higher prevalence of retinopathy in diabetic patients of South Asian ethnicity compared with white Europeans in the community: a cross-sectional study.

    PubMed

    Raymond, Neil T; Varadhan, Lakshminarayanan; Reynold, Dilini R; Bush, Kate; Sankaranarayanan, Sailesh; Bellary, Srikanth; Barnett, Anthony H; Kumar, Sudhesh; O'Hare, J Paul

    2009-03-01

    The purpose of this study was to compare prevalence and risk factors for diabetic retinopathy among U.K. residents of South Asian or white European ethnicity. This was a community-based cross-sectional study involving 10 general practices; 1,035 patients with type 2 diabetes were studied: 421 of South Asian and 614 of white European ethnicity. Diabetic retinopathy, sight-threatening retinopathy, maculopathy, and previous laser photocoagulation therapy were assessed after grading of retinal photographs. Data were collected on risk factors including age, duration, and treatment of diabetes, blood pressures, serum total cholesterol, and A1C. Patients of South Asian ethnicity had significantly higher systolic (144 vs. 137 mmHg, P < 0.0001) and diastolic (84 vs. 74 mmHg, P < 0.0001) blood pressure, A1C (7.9 vs. 7.5%, P < 0.0001), and total cholesterol (4.5 vs. 4.2 mmol/l, P < 0.0001). Diabetic retinopathy was detected in 414 (40%) patients (189 South Asian [45%] versus 225 white European [37%]; P = 0.0078). Sight-threatening retinopathy was detected in 142 (14%) patients (68 South Asian [16%] versus 74 white European [12%]; P = 0.0597). After adjustment for confounders, there were significantly elevated risks of any retinopathy and maculopathy for South Asian versus white European patients. Patients of South Asian ethnicity had a significantly higher prevalence of diabetic retinopathy and maculopathy, with significantly elevated systolic and diastolic blood pressure, A1C, and total cholesterol; lower attained age; and younger age at diagnosis. Earlier onset of disease and higher levels of modifiable risk factors make early detection of diabetes, annual referral for retinal screening, and intensive risk factor control key elements in addressing this health inequality.

  5. Orthostatic hypotension and cognitive function: cross-sectional results from the ELSA-Brasil study.

    PubMed

    Suemoto, Claudia K; Baena, Cristina P; Mill, Jose G; Santos, Itamar S; Lotufo, Paulo A; Benseñor, Isabela

    2018-03-20

    The association between orthostatic hypotension (OH) and cognitive impairment is controversial, and most studies have investigated older white adults from Western Europe and the United States. Therefore, we investigated the association between OH and cognitive performance in a large and racially diverse sample of adults using cross-sectional data from the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil). OH was defined when systolic blood pressures (SBP) decreased 20 mmHg and/or diastolic blood pressure (DBP) decreased 10 mmHg from supine to standing position. We investigated the association between OH and composite global cognition, memory, verbal fluency (VF), and Trail Making test z-scores, using multiple linear regression models. We also investigated the association of orthostatic hypertension and SBP/DBP changes with cognitive performance, as well as the interaction between OH and compensatory heart rate (HR) after postural change on cognitive performance. We evaluated 12,826 participants (mean age=51.5±9.0 years, 46% male, 53% white). Participants with OH (4% of the sample) had poorer z-scores for VF (β=-0.108, 95% CI=-0.189; -0.025, p=0.01) than participants without OH. Orthostatic hypertension was also associated with worse performance on the VF test (β=-0.080, 95% CI=-0.157; -0.003, p=0.04). SBP orthostatic change had a non-linear association with VF. The interaction terms between OH and compensatory increase in HR for the Trail Making Test z-score (p=0.09) was borderline significant, suggesting that participants who lack compensatory HR after postural change might have poorer performance. OH and orthostatic hypertension were associated with poorer performance on the VF test in participants from Brazil.

  6. Sleep History and Hypertension Burden in First-Generation Chinese Migrants Settled in Italy: The CHIinese In Prato Cross-Sectional Survey

    PubMed Central

    Modesti, Pietro A.; Calabrese, Maria; Perruolo, Eleonora; Bussotti, Alessandro; Malandrino, Danilo; Bamoshmoosh, Mohamed; Biggeri, Annibale; Zhao, Dong

    2016-01-01

    Abstract Migration flows from China are largely directed towards the South of Europe, Chinese being now the third largest overseas-born population in Italy. The aim of the study was to investigate hypertension burden and self-reported sleep disorders among 1608 first-generation Chinese migrants aged 16 to 59 years settled in Prato and recruited in a cross-sectional survey. Hypertension was defined as systolic BP ≥140 mm Hg and/or diastolic BP ≥90 mm Hg or self-reported antihypertensive treatment; potential impact of sleep disorders was analyzed by logistic regression adjusted for age, sex, marital status, education, health insurance, current smoking, parental hypertension, alcohol drinking, overweight or obesity, central obesity, diabetes, high total cholesterol, and high triglycerides. Among the 1608 participants, 21.7% were hypertensive (age-standardized prevalence 19.2%; 95% Cl: 18.5–20.0); 54% of hypertensive subjects were aware of their condition; 70% of aware hypertensive subjects received drugs, and 39% of treated subjects had blood pressure controlled. Self-reported snoring increased the risk of hypertension; when compared with no snoring, the age- and sex-adjusted OR for hypertension of snoring 3 to 6 d/week was 2.11 (95% Cl: 1.48–3.01) and 2.48 (95% Cl: 1.79–3.46) of snoring every day. When compared with a sleep duration ≤5 hours, subjects with sleep duration of 7 hours had reduced risk of high triglycerides (adjusted OR: 0.66; 95% Cl: 0.43–0.95). Despite a high level of awareness, low treatment rates for hypertension were observed among Chinese participants, independently of health insurance. Sleep history is to be considered in screening and prevention programs. PMID:27057856

  7. Periodontal disease, tooth loss and coronary heart disease assessed by coronary angiography: a cross-sectional observational study.

    PubMed

    Zanella, S M; Pereira, S S; Barbisan, J N; Vieira, L; Saba-Chujfi, E; Haas, A N; Rösing, C K

    2016-04-01

    To evaluate the association between periodontal disease, tooth loss and coronary heart disease (CHD). There is still controversy about the relationship between periodontal disease and tooth loss with vessel obstruction assessed using coronary angiography. This cross-sectional study included 195 patients that underwent coronary angiography and presented with at least six teeth. Patients were classified into three categories of coronary obstruction severity: absence; one or more vessels with ≤ 50% obstruction; and one or more vessels with ≥ 50% obstruction. The extent of coronary obstruction was dichotomized into 0 and ≥ 1 affected vessels. A periodontist blinded to patient CHD status conducted a full mouth examination to determine mean clinical attachment loss, mean periodontal probing depth and tooth loss. Multiple logistic regression models were applied adjusting for age, gender, hypertension, smoking, body mass index, low-density lipoprotein cholesterol and C-reactive protein. Most patients were males (62.1%) older than 60 years (50.8%), and 61% of them had CHD. Mean periodontal probing depth, clinical attachment loss and tooth loss were 2.64 ± 0.72 mm, 4.40 ± 1.31 mm and 12.50 ± 6.98 teeth respectively. In the multivariable models, tooth loss was significantly associated with a higher chance of having at least one obstructed vessel (odds ratio = 1.04; 95% confidence interval 1.01-1.09) and with vessel obstruction ≥ 50% (odds ratio = 1.06; 95% confidence interval 1.01-1.11). No significant associations were found between periodontal variables and vessel obstruction. Tooth loss was found to be a risk indicator for CHD. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Muscle activity patterns and spinal shrinkage in office workers using a sit-stand workstation versus a sit workstation.

    PubMed

    Gao, Ying; Cronin, Neil J; Pesola, Arto J; Finni, Taija

    2016-10-01

    Reducing sitting time by means of sit-stand workstations is an emerging trend, but further evidence is needed regarding their health benefits. This cross-sectional study compared work time muscle activity patterns and spinal shrinkage between office workers (aged 24-62, 58.3% female) who used either a sit-stand workstation (Sit-Stand group, n = 10) or a traditional sit workstation (Sit group, n = 14) for at least the past three months. During one typical workday, muscle inactivity and activity from quadriceps and hamstrings were monitored using electromyography shorts, and spinal shrinkage was measured using stadiometry before and after the workday. Compared with the Sit group, the Sit-Stand group had less muscle inactivity time (66.2 ± 17.1% vs. 80.9 ± 6.4%, p = 0.014) and more light muscle activity time (26.1 ± 12.3% vs. 14.9 ± 6.3%, p = 0.019) with no significant difference in spinal shrinkage (5.62 ± 2.75 mm vs. 6.11 ± 2.44 mm). This study provides evidence that working with sit-stand workstations can promote more light muscle activity time and less inactivity without negative effects on spinal shrinkage. Practitioner Summary: This cross-sectional study compared the effects of using a sit-stand workstation to a sit workstation on muscle activity patterns and spinal shrinkage in office workers. It provides evidence that working with a sit-stand workstation can promote more light muscle activity time and less inactivity without negative effects on spinal shrinkage.

  9. A cross-sectional study of leukopenia and thrombocytopenia among Chinese adults with newly diagnosed HIV/AIDS.

    PubMed

    Shen, Yinzhong; Wang, Jiangrong; Wang, Zhenyan; Shen, Jiayin; Tangkai Qi; Song, Wei; Tang, Yang; Liu, Li; Zhang, Renfang; Zeng, Yi; Lu, Hongzhou

    2015-04-01

    We conducted a cross-sectional study to determine the prevalence and risk factors of leukopenia and thrombocytopenia among Chinese adults with newly diagnosed HIV/AIDS. One thousand nine hundred and forty-eight newly diagnosed HIV-infected patients were enrolled between 2009 and 2010. Serum samples obtained from each individual were collected for complete blood count. Factors associated with the presence of leukopenia and thrombocytopenia were analyzed by multiple logistic regression. The overall prevalence of leukopenia and of thrombocytopenia was 33.2% and 15.6%, respectively. The prevalence of leukopenia was higher among females than among males (39.4% versus 31.2%). The prevalence of leukopenia increased with decreasing CD4 count (8.2%, 26.5%, 33.4%, and 41.5% among patients with CD4 count of ≥ 350, 200-349, 50-199, and < 50 cells/mm3 respectively). The prevalence of thrombocytopenia also showed an increasing trend with decreasing CD4 count (5.8%, 12.2%, 17.8%, and 17.5% among patients with CD4 count of ≥ 350, 200-349, 50-199, and < 50 cells/mm3, respectively). Logistic analysis showed that female sex, lower CD4 count, and Han ethnicity were significantly associated with an increased risk of leukopenia, and that lower CD4 count, and HIV transmission by blood were significantly associated with an increased risk of thrombocytopenia. The study reflects that leukopenia and thrombocytopenia are common among Chinese adults with newly diagnosed HIV/AIDS; and lower CD4 count is associated with an increased risk of both leukopenia and thrombocytopenia. We propose that a routine assessment of these parameters is necessary for timely and adequate clinical management.

  10. Changes in cross-sectional area of pulmonary vessels on chest computed tomography after chemotherapy in patients with advanced non-squamous non-small-cell lung cancer.

    PubMed

    Karayama, Masato; Inui, Naoki; Kusagaya, Hideki; Suzuki, Seiichiro; Inoue, Yusuke; Enomoto, Noriyuki; Fujisawa, Tomoyuki; Nakamura, Yutaro; Suda, Takafumi

    2016-05-01

    Chemotherapy is associated with a risk of vascular damage. Novel anti-angiogenic agents, which can directly affect tumor angiogenesis, are increasingly being used. However, the effects of these agents on normal vasculature are not well understood. Here, we evaluated the effects of chemotherapy in general, and the anti-angiogenic agent bevacizumab, more specifically, on the pulmonary vasculature in patients with advanced non-squamous non-small-cell lung cancer (NSCLC). For this, we used the cross-sectional area of pulmonary vessels (CSA), which is an easily measurable indicator of small pulmonary vasculature on non-contrast chest computed tomography (CT). We retrospectively reviewed CT scans of the lungs of 75 chemo-naïve patients with advanced non-squamous NSCLC, for measurement of CSA, before and after first-line platinum-based chemotherapy, using a semi-automatic image-processing program. Measured vessels were classified in two groups: small vessels with CSA <5 mm(2) and large vessels with CSA between 5 and 10 mm(2). The CSAs for each group of vessels were calculated and summed separately, and expressed as a percentage of the total lung area (%CSA<5 and %CSA5-10). Chemotherapy was associated with a selective decrease in small-diameter vessels, with a significant decrease in %CSA<5, but not %CSA5-10. When comparing chemotherapy with bevacizumab (n = 38) and without bevacizumab (n = 37), there was no significant difference in the reduction of %CSA<5. Platinum-based chemotherapy might induce small pulmonary vascular damage. Use of bevacizumab does not enhance the reduction in area of pulmonary vessels.

  11. Pruning of the Pulmonary Vasculature in Asthma: The SARP Cohort.

    PubMed

    Ash, Samuel Y; Rahaghi, Farbod N; Come, Carolyn E; Ross, James C; Colon, Alysha G; Cardet-Guisasola, Juan Carlos; Dunican, Eleanor M; Bleecker, Eugene R; Castro, Mario; Fahy, John V; Fain, Sean B; Gaston, Benjamin M; Hoffman, Eric A; Jarjour, Nizar N; Mauger, David T; Wenzel, Sally E; Levy, Bruce D; San Jose Estepar, Raul; Israel, Elliot; Washko, George R

    2018-04-19

    Loss of the peripheral pulmonary vasculature, termed vascular pruning, is associated with disease severity in patients with chronic obstructive pulmonary disease. To determine if pulmonary vascular pruning is associated with asthma severity and exacerbations. We measured the total pulmonary blood vessel volume (TBV) and the blood vessel volume of vessels less than 5mm2 in cross sectional area (BV5) and of vessels less than 10mm2 (BV10) in cross sectional area on non-contrast computed tomographic scans of participants from the Severe Asthma Research Program. Lower values of the BV5 to TBV ratio (BV5/TBV) and the BV10 to TBV ratio (BV10/TBV) represented vascular pruning (loss of the peripheral pulmonary vasculature). Compared to healthy controls, severe asthmatics had more pulmonary vascular pruning. Among asthmatics, those with poor asthma control had more pruning than those well-controlled disease. Pruning of the pulmonary vasculature was also associated with lower percent predicted forced expiratory volume in one second and forced vital capacity, greater peripheral and sputum eosinophilia and higher bronchoalveolar lavage SAA/LXA4, but not with low attenuation area or with sputum neutrophilia. Compared with individuals with less pruning, individuals with the most vascular pruning had a 150% greater odds of reporting an asthma exacerbation (OR 2.50; CI: 1.05, 5.98; p=0.039 for BV10/TBV), and reported 45% more asthma exacerbations during follow-up (IRR 1.45; CI: 1.02, 2.06; p=0.036 for BV10/TBV). Pruning of the peripheral pulmonary vasculature is associated with asthma severity, control and exacerbations, as well as with lung function and eosinophilia.

  12. Prevalence of parasitic infections in HIV-positive patients in southern Ethiopia: a cross-sectional study.

    PubMed

    Fekadu, Sintayehu; Taye, Kefyalew; Teshome, Wondu; Asnake, Solomon

    2013-11-15

    Intestinal parasitic infections are a major public health burden in tropical countries. Although all HIV/AIDS patients are susceptible to parasitic infections, those having lower immune status are at greater risk. The aim of this study was to determine the prevalence of intestinal parasitic infections in patients living with HIV/AIDS. This was a facility-based cross-sectional study. A total of 343 consecutively sampled HIV/AIDS patients from the HIV care clinic of Hawassa University Referral Hospital were included. Subjects were interviewed for demographic variables and diarrheal symptoms using structured questionnaires. Stool examinations and CD4 cells counts were also performed. The prevalence of intestinal parasitic infection was 47.8% among HIV/AIDS patients; single helminthic infection prevalence (22.7%) was higher than that the prevalence of protozoal infections (14.6%). About 54% of study participants had chronic diarrhea while 3.4% had acute diarrhea. The prevalence of intestinal parasites in patients with chronic diarrhea was significantly higher than in acute diarrhea (p <0.05). Non-opportunistic intestinal parasite infections such as Ascaris lumbricoides, Taenia spp., and hookworm were commonly found, regardless of immune status or diarrheal symptoms. Opportunistic and non-opportunistic intestinal parasitic infection were more frequent in patients with a CD4 count of <200/mm(3) (OR=9.5; 95% CI: 4.64-19.47) when compared with patients with CD4 counts of ≥500 cells/mm(3). Intestinal parasitic infections should be suspected in HIV/AIDS-infected patients with advanced disease presenting with chronic diarrhea. Patients with low CD4 counts should be examined critically for intestinal parasites, regardless of diarrheal status.

  13. Differences in metabolic parameters and cardiovascular risk between American Diabetes Association and World Health Organization definition of impaired fasting glucose in European Caucasian subjects: a cross-sectional study

    PubMed Central

    Filippatos, Theodosios D.; Rizos, Evangelos C.; Gazi, Irene F.; Lagos, Konstantinos; Agouridis, Dimitrios; Mikhailidis, Dimitri P.

    2013-01-01

    Introduction The American Diabetes Association (ADA) defines impaired fasting glucose (IFG) as fasting plasma glucose concentration of 100–125 mg/dl, whereas the World Health Organization (WHO) and the International Diabetes Federation (IDF) define IFG as fasting plasma glucose levels of 110–125 mg/dl. We identified differences in metabolic parameters and cardiovascular disease (CVD) risk according to the ADA or WHO/IDF definition of IFG. Material and methods Healthy drug-naive Caucasian (Greek) subjects (n = 396; age 55 ±12 years) participated in this cross-sectional study. Results Diastolic blood pressure (DBP) and uric acid levels were higher in the subjects with glucose 100–109 mg/dl compared with those with glucose < 100 mg/dl (87 ±9 mm Hg vs. 84 ±11 mm Hg, p = 0.004 for DBP, 5.6 ±1.5 mg/dl vs. 5.0 ±1.0 mg/dl, p = 0.002 for uric acid), whereas triglyceride levels were lower in subjects with glucose 100–109 mg/dl compared with those with glucose ≥ 110 mg/dl (169 mg/dl (interquartile range (IQR) = 102–186) vs. 186 mg/dl (IQR = 115–242), p = 0.002). Only the ADA definition recognized subjects with significantly increased 10-year CVD risk estimation (SCORE risk calculation) compared with their respective controls (5.4% (IQR = 0.9–7.3) vs. 4.1% (IQR = 0.7–5.8), p = 0.002). Conclusions The ADA IFG definition recognized more subjects with significantly increased CVD risk (SCORE model) compared with the WHO/IDF definition. PMID:24273558

  14. The inter-arm blood pressure difference and peripheral vascular disease: cross-sectional study.

    PubMed

    Clark, Christopher E; Campbell, John L; Powell, Roy J; Thompson, John F

    2007-10-01

    A blood pressure (BP) difference between the upper limbs is often encountered in primary care. Knowledge of its prevalence and importance in the accurate measurement of BP is poor, representing a source of error. Current hypertension guidelines do not emphasize this. To establish the prevalence of an inter-arm blood pressure difference (IAD) and explore its association with other indicators of peripheral vascular disease (PVD) in a hypertensive primary care population. This was a cross-sectional study. Primary care, one rural general practice, was the setting of the study. The methods were controlled simultaneous measurement of brachial BPs, ankle-brachial pressure index (ABPI) and tiptoe stress testing in 94 subjects. In all, 18 of 94 [19%, 95% confidence interval (CI) 11-27%] subjects had mean systolic inter-arm difference (sIAD) > or =10 mmHg and seven of 94 (7%, 95% CI 2-12%) had mean diastolic inter-arm difference (dIAD) > or =10 mmHg. Nineteen of 91 (20%, 95% CI 12-28%) had a reduced ABPI <0.9. There was negative correlation between systolic (Pearson's correlation coefficient - 0.378; P = 0.01) and diastolic (Pearson's correlation coefficient - 0.225; P = 0.05) magnitudes of IAD with ABPI. On tiptoe testing, 9/90 subjects (10%, 95% CI 4-16%) had a pressure drop > or =20%. An IAD and asymptomatic PVD are common in a primary care hypertensive population. Magnitude of the IAD is inversely correlated with ABPI, supporting the hypotheses that IADs are causally linked to PVD, and that IAD is a useful marker for the presence of PVD. Consequently, detection of an IAD should prompt the clinician to screen subjects for other signs of vascular disease and target them for aggressive cardiovascular risk factor modification.

  15. An in vitro study into the efficacy of complex tooth alignment with conventional and self-ligating brackets.

    PubMed

    Montasser, M A; Keilig, L; Bourauel, C

    2015-02-01

    To evaluate the efficacy of tooth alignment achieved by various small cross-section archwire/bracket combinations using the orthodontic measurement and simulation system. The study comprised three types of orthodontic brackets 1) conventional ligating (Victory Series and Mini-Taurus), 2) self-ligating (SmartClip a passive self-ligating bracket and Time3 an active self-ligating bracket), and 3) a conventional low-friction bracket (Synergy). All brackets had a nominal 0.022″ slot size. Brackets were combined with 1) 0.012″ stainless steel, 2) 0.012″ Orthonol, 3) 0.012″ Thermalloy, and 4) 0.0155″ coaxial archwires. Archwires were tied to the conventional brackets with stainless steel ligatures and elastomeric rings. The malocclusion simulated represented a central upper incisor displaced 2 mm gingivally (x-axis) and 2 mm labially (z-axis). The inciso-gingival correction achieved by the different archwire/bracket combinations ranged from 15 to 95%, while the labio-lingual correction ranged from 10 to 95%. The smallest correction was achieved by coaxial, Orthonol, and thermally archwires when ligated with the elastomeric rings to conventional brackets. Stainless steel archwires achieved from 65 to 90% of inciso-gingival correction and from 60 to 90% of labio-lingual correction. The resultant tooth alignment was the product of interaction between the archwire type, bracket type, and bracket design including ligature type. Small cross-sectional archwires might produce up to 95% correction if combined properly with the bracket system. Elastomeric rings when used with conventional brackets limit the efficacy of malalignment correction. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Ultrasound is a reproducible and valid tool for measuring scar height in children with burn scars: A cross-sectional study of the psychometric properties and utility of the ultrasound and 3D camera.

    PubMed

    Simons, M; Kee, E Gee; Kimble, R; Tyack, Z

    2017-08-01

    The aim of this study was to investigate the reproducibility and validity of measuring scar height in children using ultrasound and 3D camera. Using a cross-sectional design, children with discrete burn scars were included. Reproducibility was tested using Intraclass Correlation Coefficient (ICC) for reliability, and percentage agreement within 1mm between test and re-test, standard error of measurement (SEM), smallest detectable change (SDC) and Bland Altman limits of agreement for agreement. Concurrent validity was tested using Spearman's rho for support of pre-specified hypotheses. Forty-nine participants (55 scars) were included. For ultrasound, test-retest and inter-rater reproducibility of scar thickness was acceptable for scarred skin (ICC=0.95, SDC=0.06cm and ICC=0.82, SDC=0.14cm). The ultrasound picked up changes of <1mm. Inter-rater reproducibility of maximal scar height using the 3D camera was acceptable (ICC=0.73, SDC=0.55cm). Construct validity of the ultrasound was supported with a strong correlation between the measure of scar thickness and observer ratings of thickness using the POSAS (ρ=0.61). Construct validity of the 3D camera was also supported with a moderate correlation (ρ=0.37) with the same measure using maximal scar height. The ultrasound is capable of detecting smaller changes or differences in scar thickness than the 3D camera, in children with burn scars. However agreement as part of reproducibility was lower than expected between raters for the ultrasound. Improving the accuracy of scar relocation may go some way to address agreement. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  17. Measurement of esophago-gastric junction cross-sectional area and distensibility by an endolumenal functional lumen imaging probe for the diagnosis of gastro-esophageal reflux disease.

    PubMed

    Tucker, E; Sweis, R; Anggiansah, A; Wong, T; Telakis, E; Knowles, K; Wright, J; Fox, M

    2013-11-01

    Measurement of esophago-gastric junction (EGJ) cross-sectional area (CSA) and distensibility by an Endolumenal Functional Lumen Imaging Probe (EndoFLIP®) may distinguish between gastro-esophageal reflux disease (GERD) patients and healthy volunteers (HV). We aimed to assess the agreement of EndoFLIP® measurements with clinical and physiologic diagnosis of GERD. Twenty-one HV and 18 patients with typical GERD symptoms were studied. After gastroscopy, EGJ CSA, and distensibility were measured by EndoFLIP®. Forty-eight hour esophageal pH monitoring was then performed by a wireless system. The ability of EndoFLIP® to discriminate GERD patient and HVs was assessed. Planned secondary analysis then assessed whether EGJ CSA and distensibility were increased in individuals with pathologic acid exposure. Healthy volunteers were younger and had lower body mass index (BMI; both p < 0.001). Pathologic acid exposure was present in 3/21 (14%) HVs and 9/18 (50%) patients (p = 0.126). At 30 mL EndoFLIP® bag volume, EGJ CSA was higher (p = 0.058) and EGJ distensibility was lower (p = 0.020) in HVs than patients. Secondary analysis showed that EGJ measurements were similar in participants with and without pathologic acid exposure (CSA 98 mm² vs 107 mm²; p = 0.789, distensibility; p = 0.704). An inverse association between BMI and CSA (R² = 0.2758, p = 0.001) and distensibility (R² = 0.2005, p = 0.005) was present. Endolumenal Functional Lumen Imaging Probe is not useful for GERD diagnosis because EGJ CSA and distensibility do not distinguish between HVs and GERD patients defined by clinical presentation or pH measurement. This unexpected result may be due to an important, confounding interaction of obesity. © 2013 John Wiley & Sons Ltd.

  18. Ultrasound pressure distributions generated by high frequency transducers in large reactors.

    PubMed

    Leong, Thomas; Coventry, Michael; Swiergon, Piotr; Knoerzer, Kai; Juliano, Pablo

    2015-11-01

    The performance of an ultrasound reactor chamber relies on the sound pressure level achieved throughout the system. The active volume of a high frequency ultrasound chamber can be determined by the sound pressure penetration and distribution provided by the transducers. This work evaluated the sound pressure levels and uniformity achieved in water by selected commercial scale high frequency plate transducers without and with reflector plates. Sound pressure produced by ultrasonic plate transducers vertically operating at frequencies of 400 kHz (120 W) and 2 MHz (128 W) was characterized with hydrophones in a 2 m long chamber and their effective operating distance across the chamber's vertical cross section was determined. The 2 MHz transducer produced the highest pressure amplitude near the transducer surface, with a sharp decline of approximately 40% of the sound pressure occurring in the range between 55 and 155 mm from the transducer. The placement of a reflector plate 500 mm from the surface of the transducer was shown to improve the sound pressure uniformity of 2 MHz ultrasound. Ultrasound at 400 kHz was found to penetrate the fluid up to 2 m without significant losses. Furthermore, 400 kHz ultrasound generated a more uniform sound pressure distribution regardless of the presence or absence of a reflector plate. The choice of the transducer distance to the opposite reactor wall therefore depends on the transducer plate frequency selected. Based on pressure measurements in water, large scale 400 kHz reactor designs can consider larger transducer distance to opposite wall and larger active cross-section, and therefore can reach higher volumes than when using 2 MHz transducer plates. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  19. Cytoplasm-to-myonucleus ratios following microgravity.

    PubMed

    Kasper, C E; Xun, L

    1996-10-01

    The cytoplasmic volume-to-myonucleus ratio in the tibialis anterior and gastrocnemius muscles of juvenile rats after 5.4 days of microgravity was studied. Three groups of rats (n = 8 each) were used. The experimental group (space rats) was flown aboard the space shuttle Discovery (NASA, STS-48), while two ground-based groups, one hindlimb suspended (suspended rats), one non-suspended (control), served as controls. Single fibre analysis revealed a significant decrease in cross-sectional area (microns2) in the gastrocnemius for both the space and the suspended rats; in the tibialis anterior only the suspended rats showed a significant decrease. Myonuclei counts (myonuclei per mm) in both the tibialis anterior and gastrocnemius were significantly increased in the space rats but not in the suspended rats. The mean myonuclear volume (individual nuclei: microns3) in tibialis anterior fibres from the space rats, and in gastrocnemius fibres from both the space and the suspended rats, was significantly lower than that in the respective control group. Estimation of the total myonuclear volume (microns3 per.mm), however, revealed no significant differences between the three groups in either the tibialis anterior or gastrocnemius. The described changes in the cross-sectional area and myonuclei numbers resulted in significant decreases in the cytoplasmic volume-to-myonucleus ratio (microns3 x 10(3)) in both muscles and for both space and suspended rats (tibialis anterior; 15.6 +/- 0.6 (space), 17.2 +/- 1.0 (suspended), 20.8 +/- 0.9 (control): gastrocnemius; 13.4 +/- 0.4 (space) and 14.9 +/- 1.1 (suspended) versus 18.1 +/- 1.1 (control)). These results indicate that even short periods of unweighting due to microgravity or limb suspension result in changes in skeletal muscle fibres which lead to significant decreases in the cytoplasmic volume-to-myonucleus ratio.

  20. Quantitative assessment of paravalvular leakage after transcatheter aortic valve replacement using a patient-specific pulsatile flow model.

    PubMed

    Tanaka, Yutaka; Saito, Shigeru; Sasuga, Saeko; Takahashi, Azuma; Aoyama, Yusuke; Obama, Kazuto; Umezu, Mitsuo; Iwasaki, Kiyotaka

    2018-05-01

    Quantitative assessment of post-transcatheter aortic valve replacement (TAVR) aortic regurgitation (AR) remains challenging. We developed patient-specific anatomical models with pulsatile flow circuit and investigated factors associated with AR after TAVR. Based on pre-procedural computed tomography (CT) data of the six patients who underwent transfemoral TAVR using a 23-mm SAPIEN XT, anatomically and mechanically equivalent aortic valve models were developed. Forward flow and heart rate of each patient in two days after TAVR were duplicated under mean aortic pressure of 80mmHg. Paravalvular leakage (PVL) volume in basal and additional conditions was measured for each model using an electromagnetic flow sensor. Incompletely apposed tract between the transcatheter and aortic valves was examined using a micro-CT. PVL volume in each patient-specific model was consistent with each patient's PVL grade, and was affected by hemodynamic conditions. PVL and total regurgitation volume increased with the mean aortic pressure, whereas closing volume did not change. In contrast, closing volume increased proportionately with heart rate, but PVL did not change. The minimal cross-sectional gap had a positive correlation with the PVL volumes (r=0.89, P=0.02). The gap areas typically occurred in the vicinity of the bulky calcified nodules under the native commissure. PVL volume, which could be affected by hemodynamic conditions, was significantly associated with the minimal cross-sectional gap area between the aortic annulus and the stent frame. These data may improve our understanding of the mechanism of the occurrence of post-TAVR PVL. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  1. The association of nonalcoholic fatty liver disease with central and peripheral blood pressure in adolescence: findings from a cross-sectional study

    PubMed Central

    Patel, Sumaiya; Lawlor, Debbie A.; Ferreira, Diana L.S.; Hughes, Alun D.; Chaturvedi, Nish; Callaway, Mark; Day, Chris; Sattar, Naveed; Fraser, Abigail

    2015-01-01

    Objectives: We aimed to determine the association of nonalcoholic fatty liver disease (NAFLD) with central and peripheral blood pressure (BP), in a general adolescent population and to examine whether associations are independent of adiposity. Methods: Using cross-sectional data from a subsample (N = 1904) of a UK birth cohort, we assessed markers of NAFLD including ultrasound scan (USS) determined fatty liver, shear velocity (marker of liver fibrosis), alanine aminotransferase (ALT), aspartate aminotransferase (AST) and gamma-glutamyltransferase (GGT) at a mean age of 17.8 years. These were related to BP [central and peripheral SBP and DBP and mean arterial pressure (MAP)]. Results: Fatty liver was positively associated with central and peripheral SBP, DBP and MAP in models adjusting for age, sex, social class, puberty and alcohol intake. These positive associations were attenuated to the null when fat mass was included. For example, in confounder-adjusted models, not including fat mass, mean central SBP was 3.74 mmHg [95% confidence interval (CI) 1.12 to 6.36] higher in adolescents with USS fatty liver than in those without; with additional adjustment for fat mass, the association attenuated to the null value (−0.37 mmHg; 95% CI –3.09 to 2.36). Similar patterns were found for associations of ALT and GGT with central and peripheral BP. There was no consistent evidence of associations of shear velocity or AST with BP measurements. Fatty liver was not consistently associated with central pulse pressure (PP), peripheral PP and Aix@75. Conclusion: NAFLD is not associated with higher central or peripheral BP in adolescents once confounding by adiposity is taken into account. PMID:25426570

  2. Geographical Variation in Prevalence of Cryptococcal Antigenemia among HIV-infected Treatment-Naïve Patients in Nigeria: A multicenter cross-sectional study

    PubMed Central

    Ezeanolue, Echezona E.; Nwizu, Chidi; Greene, Gregory S.; Amusu, Olatilewa; Chukwuka, Chinwe; Ndembi, Nicaise; Smith, Rachel M.; Chiller, Tom; Pharr, Jennifer; Kozel, Thomas R

    2016-01-01

    Objective Worldwide, HIV-associated cryptococcal meningitis affects approximately 1 million persons and causes 600,000 deaths each year mostly in sub-Sharan Africa. Limited data exist on cryptococcal meningitis and antigenemia in Nigeria, and most studies are geographically restricted. We determined the prevalence of cryptococcal antigenemia (CrAg) among HIV-infected treatment-naïve individuals in Nigeria. Design/Methods This was a retrospective, cross-sectional study across four geographic regions in Nigeria. We performed CrAg testing using a lateral flow immunoassay on archived whole blood samples collected from HIV-infected participants at US PEPFAR-supported sites selected to represent the major geographical and ethnic diversity in Nigeria. Eligible samples were (1) stored in an -80° freezer; (2) collected from consenting patients (>15 years) naïve to antiretroviral therapy with CD4+ count less than 200 cells/mm3. Results A total of 2,752 stored blood samples were retrospectively screened for CrAg. A majority of samples were from participants aged 30 - 44 (57.6%), and 1,570 (57.1%) were from women. The prevalence of CrAg positivity in specimens with CD4 < 200 cells/mm3 was 2.3% (95% CI = 1.8%-3.0%), and varied significantly across the four regions (p < 0.001). At 4.4% (3.2%-5.9%), the South East contained the highest prevalence. Conclusion The significant regional variation in CrAg prevalence found in Nigeria should be taken into consideration as plans are made to integrate routine screening into clinical care for HIV-infected patients. PMID:27144527

  3. Distortion of the temporary cavity and its influence on staining in firearm barrels.

    PubMed

    Schyma, Christian; Müller, Rolf; Brenčičová, Eva; Brünig, Julia

    2018-06-01

    After contact shots to the head, biological traces can be found inside the barrel of the firearm. Experimental protocols to generate this sort of staining, using 12 cm gelatin cubes containing thin foil bags filled with acrylic paint, human blood, and radiocontrast agent, have been developed. Previous research on shots fired at a distance has shown the underlay sustaining these gelatin cubes has an influence on experimental results. This study was conducted to investigate the role of the sustaining base of the gelatin blocks during contact shots, and its influence on the staining result inside firearm barrels. Eighteen contact shots were performed using 22 LR, 32 ACP (7.65 Browning) and 9 mm Luger semi-automatic pistols. With each pistol, shots were fired onto six gelatin cubes; three placed upon a rigid platform and three upon an elastic underlay. The shots were recorded by a high-speed video camera as they penetrated the gelatin cube. Any staining present inside the firearm barrels after the shots were fired was documented by endoscopy. Cross sections of the gelatin blocks were then compared to the high-speed video. It was found that the nature of the staining inside the barrel was not influenced by the underlay sustaining the target model. In the experiment using a 9 mm Luger, the rigid counterfort provoked a visible distortion of the temporary cavity, but, cross sectional analysis of the gelatin cubes did not reveal a relevant influence of the sustaining underlay on the crack length in the gelatin. This could be explained by a secondary expansion of the temporary cavity left by the projectile as a consequence of subsequent inflow of muzzle gases.

  4. Central systolic blood pressure is associated with ethnicity and cardiovascular disease risk factors in Chinese middle-aged population.

    PubMed

    Wang, Zengwu; Hao, Guang; Zhang, Linfeng; Chen, Zuo; Wang, Xin; Guo, Min; Tian, Ye; Shao, Lan; Zhu, Manlu

    2016-02-01

    Central systolic blood pressure (CSBP) is a useful prognostic aid in the reduction and prevention of cardiovascular diseases. However, data regarding the distribution of CSBP in China are not available. The study aimed at assessing the distribution of CSBP and examining its relationship with potential cardiovascular risk factors in the Chinese middle-aged population. A cross-sectional study. A cross-sectional survey on cardiovascular risk factors across China was conducted in 2009-2010. CSBP levels were estimated using the non-invasive BPro device with A-Pulse central aortic systolic pressure software. The study population included 9113 individuals (mean age 49.84 years; 53.37% women). The CSBP levels (mean (standard deviation)) were 119.46 (17.51) mmHg in men and 119.81 (19.29) mmHg in women. CSBP levels were higher in rural than urban and lower in the southern than the northern populations (both P < 0.05). The Han ethnic group had higher CSBP levels than the Tibetans (P < 0.05) but similar to those in the Mongolian, Uyghur, Kazak and Akha groups. Irrespective of gender, the mean CSBP level was higher in individuals with diabetes and hypertension than in those without these disorders (P < 0.05). CSBP was positively associated with cardiovascular risk factors such as age, female gender, body mass index, systolic and diastolic blood pressure, and negatively associated with heart rate. CSBP estimated using the BPro device correlates with various cardiovascular risk factors. Our results may help establish future reference values in the Chinese middle-aged population. © The European Society of Cardiology 2015.

  5. Anthropometry of Arabian nose using computed tomography scanning.

    PubMed

    Alharethy, Sami; Al-Quniabut, Ibrahim; Jang, Yong Ju

    2017-01-01

    The nose plays a critical role in determining the external appearance of an individual. We studied the craniofacial anthropometrics by CT scanning since previous studies in the field were conducted in Saudi populations using photometric analysis. Obtain objective and quantitative data that can help surgeons plan cosmetic procedures for the nose. A cross-sectional analytical study. Department of Otorhinolaryngology, Head and Neck Surgery, King Abdulaziz University Hospital, King Saud University, Riyadh, Saudi Arabia from February 2015 to December 2015. Facial CT scans were performed on native Saudis who underwent CT of the paranasal sinuses. Three anthropometric parameters: the nasofrontal angle, the pyramidal angle, and the linear distance between the nasion and the tip of the nasal bone. In 160 native Saudis (86 males and 74 females) who underwent CT, the mean nasofrontal angle was 125.3° in males and 135.6° in females. The mean linear distance between the nasion and the tip of the nasal bone was 23.0 mm for males and 20.9 mm for females. The mean nasal pyramidal angle was 110.8° in males and 111.9° for females at the level of the nasal root, 105.6° in males and 104.8° in females at the mid-level of the nasal bone, and 116.8° males and 107.9° in females at the level of the tip of the nasal bone. Nasal bone lengths and angles can be obtained accurately from CT scans. These angles differ in different ethnic groups. The sample represents native Saudis but not a cross section of the Saudi population. The relatively small sample size is a limitation of the study, but we consider these to be initial findings.

  6. Association of narrow angles with anterior chamber area and volume measured with anterior-segment optical coherence tomography.

    PubMed

    Wu, Ren-Yi; Nongpiur, Monisha E; He, Ming-Guang; Sakata, Lisandro M; Friedman, David S; Chan, Yiong-Huak; Lavanya, Raghavan; Wong, Tien-Yin; Aung, Tin

    2011-05-01

    To describe the measurement of anterior chamber area and anterior chamber volume by anterior-segment optical coherence tomography and to investigate the association of these parameters with the presence of narrow angles. This was a cross-sectional study of subjects aged at least 50 years without ophthalmic symptoms recruited from a community clinic. All participants underwent standardized ocular examination and anterior-segment optical coherence tomography. Customized software was used to measure anterior chamber area (cross-sectional area bounded by the corneal endothelium, anterior surface of iris, and lens within the pupil) and anterior chamber volume (calculated by rotating the anterior chamber area 360° around a vertical axis through the midpoint of the anterior chamber area). An eye was considered to have narrow angles if the posterior pigmented trabecular meshwork was not visible for at least 180° on gonioscopy with the eye in the primary position. A total of 1922 subjects were included in the final analyses, 317 (16.5%) of whom had narrow angles. Mean anterior chamber area (15.6 vs 21.1 mm(2); P < .001) and anterior chamber volume (97.6 vs 142.1 mm(3); P < .001) were smaller in eyes with narrow angles compared with those in eyes without narrow angles. After adjusting for age, sex, anterior chamber depth, axial length, and pupil size, smaller anterior chamber area (odds ratio, 53.2; 95% confidence interval, 27.1-104.5) and anterior chamber volume (odds ratio, 40.2; 95% confidence interval, 21.5-75.2) were significantly associated with the presence of narrow angles. Smaller anterior chamber area and anterior chamber volume were independently associated with narrow angles in Singaporeans, even after controlling for other known ocular risk factors.

  7. Modeling and characterization of the CEJ for optimization of esthetic implant design.

    PubMed

    Gallucci, German O; Belser, Urs C; Bernard, Jean-Pierre; Magne, Pascal

    2004-02-01

    This study evaluated the dimensions and characteristics of the cementoenamel junction (CEJ) of maxillary anterior teeth; the natural CEJ was compared to current implant design and used for design optimization. Standardized digital images of 137 extracted human teeth (45 central incisors, 46 lateral incisors, and 46 canines) were used to measure cervical dimensions, CEJ curvature, and distance from zenith of CEJ to interdental contact on proximal views. The x- and y-coordinates of the CEJ contour were digitized before mathematic processing to allow the representation of a single average curve for buccal, palatal, mesial, and distal surfaces for each tooth type. These measurements were combined to existing data related to dentogingival and "implantomucosal" junction to extrapolate specific biologic landmarks around teeth and implants. Mean cervical dimensions, distance from zenith of CEJ to interdental contact, and CEJ curvature were compared. Cervical dimensions significantly differed, with a more symmetric cervical cross-section for central incisors, slightly more rectangular shape for lateral incisors, and distinctly rectangular shape for canines. CEJ curvature was statistically different between all tooth groups (centrals > laterals > canines); within groups, curvature value was always superior at the mesial aspect compared to distally (3.46 mm vs 3.13 mm for centrals, 2.97 mm vs 2.38 mm for laterals, and 2.55 mm vs 1.60 mm for canines). Tooth-implant biologic width discrepancies ranged from 4.10 to 5.96 mm and were different between all groups of teeth (centrals > laterals > canines); within groups, the discrepancy was always superior at the mesial aspect compared to distally. Current implant design featuring a flat, rotation-symmetric shoulder should be reconsidered in view of natural CEJ contour to improve biologic considerations and related esthetics.

  8. Depression and anxiety among chronic pain patients receiving prescription opioids and medical marijuana.

    PubMed

    Feingold, Daniel; Brill, Silviu; Goor-Aryeh, Itay; Delayahu, Yael; Lev-Ran, Shaul

    2017-08-15

    High rates of depression and anxiety have been consistently reported among patients suffering from chronic pain. Prescription opioids are one of the most common modalities for pharmacological treatment of pain, however in recent years medical marijuana(MM) has been increasingly used for pain control in the US and in several countries worldwide. The aim of this study was to compare levels of depression and anxiety among pain patients receiving prescription opioids and MM. Participants were patients suffering from chronic pain treated with prescription opioids (OP,N=474), MM (N=329) or both (OPMM,N=77). Depression and anxiety were assessed using the depression module of the Patient Health Questionnaire (PHQ-9) and the Generalized Anxiety Disorder scale (GAD-7). Prevalence of depression among patients in the OP, MM and OPMM groups was 57.1%, 22.3% and 51.4%, respectively and rates of anxiety were 48.4%, 21.5% and 38.7%, respectively. After controlling for confounders, patients in the OP group were significantly more likely to screen positive for depression (Adjusted Odds Ratio(AOR)=6.18;95%CI=4.12-9.338) and anxiety(AOR=4.12;CI=3.84-5.71)) compared to those in the MM group. Individuals in the OPMM group were more prone for depression (AOR for depression=3.34;CI=1.52-7.34)) compared to those in the MM group. Cross-sectional study, restricting inference of causality. Levels of depression and anxiety are higher among chronic pain patients receiving prescription opioids compared to those receiving MM. Findings should be taken into consideration when deciding on the most appropriate treatment modality for chronic pain, particularly among those at risk for depression and anxiety. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. [Comparative study of N, P output and eutrophication risk in runoff water in cross ridge and longitudinal ridge].

    PubMed

    Yu, Xing-Xiu; Ma, Qian; Liu, Qian-Jin; Lü, Guo-An

    2011-02-01

    Field in-situ rainfall simulation tests with two rainfall intensities (40 mm x h(-1) and 70 mm x h(-1)), which were conducted at typical sloping cropland in Yimeng mountainous area, were designed to analyze the output characteristics of dissolved inorganic nitrogen, Inorganic-N (NO3(-)-N, NH4(+) -N) and dissolved phosphorus (DP) in runoff water, as well as to compare the eutrophication risk in this water by calculating three ratios of Inorganic-N/DP, NO3(-) -N/DP, and NH4(+)-N/DP, respectively, in cross ridge and longitudinal ridge tillage methods. Results showed that, under the same rainfall intensity, the DP level in runoff water was higher in cross ridge than longitudinal ridge, while the change of different Inorganic-N level between the two tillage methods were not consistent. Cross ridge could effectively reduce runoff and the output rate of Inorganic-N and DP when compared to the longitudinal ridge tillage, which would be more outstanding with the increases of rainfall intensities. The losses of Inorganic-N and DP in runoff water were 43% and 5% less, respectively, in cross ridge than longitudinal ridge at the 40 mm x h(-1) rainfall intensity, and were 68% and 55%, respectively, at 70 mm x h(-1). The higher Inorganic-N/DP and NO3(-) -N/DP ratios suggest that runoff water from either cross ridge or longitudinal ridge tillage have a certain eutrophication risk, which present an increasing trend during the precipitation-runoff process. Compared with longitudinal ridge, cross ridge can not only hinder the increasing trend of eutrophication risk, but also can significantly lower it, and thus effectively reduce the effect of sloping cropland runoff on the eutrophication processes of receiving waters.

  10. Effect of topical corneal anaesthesia on ocular response analyzer parameters: pilot study.

    PubMed

    Ehongo, A; De Maertelaer, V; Pourjavan, S

    2009-10-01

    The effect of topical corneal anaesthesia on corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and corneal compensated IOP (IOPcc) was measured by ocular response analyzer (ORA). Observational, cross-sectional study. We examined both eyes of 23 healthy volunteers. Patients with external eye disease, previous refractive surgery, contact lenses or topical medication were excluded. ORA parameters were first measured in both eyes. Oxybuprocaïne 0.4% eye drop was instilled in the right eyes (RE) and physiologic saline in the left eyes (LE) as a control to rule out the lubrication effect. After 2 min, the ORA measurements were performed again. Goldmann applanation tonometry (GAT) was finally done. Data are expressed as mean +/- standard deviation (SD). The medians of the four CH, CRF, IOPg, and IOPcc values measured before and after instillation were compared by using Wilcoxon signed ranks tests for RE and LE. The mean age was 39.5 +/- 11.6 years. The mean GAT was 13.1 +/- 2.5 mmHg for RE and 12.8 +/- 2.5 mmHg for LE. In the RE, the respective values for the two sequences were IOPcc = 15.6 +/- 2.6 mmHg and 15 +/- 2.8 mmHg (P = 0.036); IOPg = 15.3 +/- 3.3 mmHg and 15.4 +/- 3.5 mmHg (P = 0.806); CH = 11 +/- 1.3 mmHg and 11.1 +/- 1.4 mmHg (P = 0.563); CRF = 11.1 +/- 1.8 mmHg and 10.9 +/- 1.9 mmHg (P = 0.053). In the LE, the respective values for the two sequences were IOPcc = 15.4 +/- 2.6 mmHg and 15.6 +/- 2.8 mmHg (P = 0.903); IOPg = 15.5 +/- 3.5 mmHg and 15.4 +/- 3.4 mmHg (P = 0.208); CH = 10.8 +/- 1.4 mmHg and 10.7 +/- 1.7 mmHg (P = 0.494); CRF = 10.7 +/- 1.8 mmHg and 10.7 +/- 2.2 mmHg (P = 0.626). Two minutes after instillation, topical corneal anaesthetic slightly decreases IOPcc and also-but not statistically significantly-CRF. We did not find any statistical significant difference in CH or IOPg before and after topical corneal anaesthesia. Further investigation with more patients should be advised.

  11. Flow in out-of-plane double S-bonds

    NASA Technical Reports Server (NTRS)

    Schmidt, M. C.; Whitelaw, J. H.; Yianneskis, M.

    1986-01-01

    Developing flows in two out-of-plane double S-bend configurations have been measured by laser-Doppler anemometry. The first duct had a rectangular cross-section 40mmx40mm at the inlet and consisted of a uniform area 22.5 deg. - 22.5 deg. S-duct upstream with a 22.5 deg.- 22.5 deg. S- diffuser downstream. The second duct had a circular cross-section and consisted of a 45 deg. - 45 deg. uniform area S-duct upstream with a 22.5 deg. -22.5 deg. S-diffuser downstream. In both configurations the ratio of the mean radius of curvature to the inlet hydraulic diameter was 7.0, the exit-to-inlet area ratio of the diffusers was 1.5 and the ducts were connected so that the centerline of the S-duct lay in a plane normal to that of the S-diffuser. Streamwise and cross-stream velocity components were measured in laminar flow for the rectangular duct and in turbulent flow for both configurations; measurements of the turbulence levels, cross-correlations and wall static pressures were also made in the turbulent flow cases. Secondary flows of the first kind are present in the first S-duct and they are complemented or counteracted by the secondary flows generated by the area expansion and by the curvature of the S-diffusers downstream. Cross-stream velocities with magnitudes up to 0.19 and 0.11 of the bulk velocity were measured in the laminar and turbulent flows respectively in the rectangular duct and six cross-flow vortices were evident at the exit of the duct in both flow cases. The turbulent flow in the circular duct was qualitatively similar to that in the rectangular configuration, but the cross-stream velocities measured at the exit plane were smaller in the circular geometry. The results are presented in sufficient detail and accuracy for the assessment of numerical calculation methods and are listed in tabular form for this purpose.

  12. The dose from Compton backscatter screening.

    PubMed

    Rez, Peter; Metzger, Robert L; Mossman, Kenneth L

    2011-04-01

    Systems based on the detection of Compton backscattered X rays have been deployed for screening personnel for weapons and explosives. Similar principles are used for screening vehicles at border-crossing points. Based on well-established scattering cross sections and absorption coefficients in conjunction with reasonable estimates of the image contrast and resolution, the entrance skin dose and the dose at a depth of 1 cm can be calculated. The effective dose can be estimated using the same conversion coefficients as used to convert exposure measurements to the effective dose. It is shown that the effective dose is highly dependent on image resolution (i.e. pixel size).The effective doses for personnel screening systems are unlikely to be in compliance with the American National Standards Institute standard NS 43.17 unless the pixel sizes are >4 mm. Nevertheless, calculated effective doses are well below doses associated with health effects.

  13. Radiation and scattering from bodies of translation. Volume 2: User's manual, computer program documentation

    NASA Astrophysics Data System (ADS)

    Medgyesi-Mitschang, L. N.; Putnam, J. M.

    1980-04-01

    A hierarchy of computer programs implementing the method of moments for bodies of translation (MM/BOT) is described. The algorithm treats the far-field radiation and scattering from finite-length open cylinders of arbitrary cross section as well as the near fields and aperture-coupled fields for rectangular apertures on such bodies. The theoretical development underlying the algorithm is described in Volume 1. The structure of the computer algorithm is such that no a priori knowledge of the method of moments technique or detailed FORTRAN experience are presupposed for the user. A set of carefully drawn example problems illustrates all the options of the algorithm. For more detailed understanding of the workings of the codes, special cross referencing to the equations in Volume 1 is provided. For additional clarity, comment statements are liberally interspersed in the code listings, summarized in the present volume.

  14. A Historical Perspective on Presentations of Hypertensive Acute Heart Failure.

    PubMed

    Darling, Chad E; Sun, Jiaoyuan Elisabeth; Goldberg, Jordan; Pang, Peter; Baugh, Christopher W; Lessard, Darleen; McManus, David D

    2017-05-01

    The initial systolic blood pressure (SBP) in patients presenting to the hospital with acute heart failure (AHF) informs prognosis, diagnosis, and guides initial treatment. However, over time AHF presentations with elevated SBP appear to have declined. The present study examined whether the frequency of AHF presentations with systolic hypertension (SBP >160 mmHg) declined over a nearly two-decade time interval. This study compares four historical, cross-sectional cohorts with AHF who were admitted to tertiary care medical centres in the North-eastern USA in 1995, 2000, 2006, and 2011-13. The main outcome was the proportion of AHF patients presenting with an initial SBP >160 mmHg. 2,366 patients comprised the study sample. The average age was 77 years, 55% were female, 94% white, and 75% had prior heart failure. In 1995, 34% of AHF patients presented with an initial SBP >160 mmHg compared to 20% in 2011-2013 (p<0.01). Multivariate logistic regression demonstrated reduced odds of presenting with a SBP >160 mmHg in 2006 (0.64, 95% CI 0.42-0.96) and 2011-13 (0.46, 95% CI 0.28-0.74) compared with patients in 1995. The proportion of patients with AHF and initial SBP >160 mmHg significantly declined over the study time period. There are several potential reasons for this observation and these findings highlight the need for ongoing surveillance of patients with AHF as changing clinical characteristics can impact early treatment decisions.

  15. Penile Length and Anogenital Distance in Male Newborns From Different Iranian Ethnicities in Golestan Province

    PubMed Central

    Alaee, Ehsan; Gharib, Mohammad Javad; Fouladinejad, Mahnaz

    2014-01-01

    Background: Anogenital distance (AGD) is a feasible and accepted parameter of exogenous or endogenous androgens effects on development of reproductive system. Objectives: Since there is no report on penile length (PL) and AGD in our region, we investigated these parameters in male newborns in Golestan Province, Iran. Patients and Methods: In this cross-sectional study, we measured stretched PL and AGD in term newborns from different races in Dezyani Gynecologic Hospital of Gorgan, Iran. We also recorded the anthropometric parameters and maternal age. The data was analyzed using the SPSS 14. Results: Means of PL and AGD of 427 healthy term newborns were 32.1 ± 3.5 and 24.5 ± 2.5 mm, respectively. There was a positive correlation between PL and AGD (r = 0.097, P = 0.046). According to their ethnicity, there were 166 Fars (38.9%), 129 Turkmen (30.2%), and 132 Sistani (30.9%) infants with mean PL of respectively 31.8 ± 3.9, 32.3 ± 3.3, and 32.4 ± 3.3 mm and mean AGD of respectively 25 ± 2.5, 24.3 ± 2.5, and 24 ± 2.5 mm. One Fars neonate (0.23%) had micropenis (PL = 21.3 mm). Conclusions: Using -2.5 standard deviations as the cutoff for micropenis, a newborn infant in Golestan Province with a PL of < 23.3 mm had micropenis; however, more investigations are needed to clarify this issue. PMID:25763234

  16. Effect of slice thickness on image noise and diagnostic content of single-source-dual energy computed tomography

    NASA Astrophysics Data System (ADS)

    Alshipli, Marwan; Kabir, Norlaili A.

    2017-05-01

    Computed tomography (CT) employs X-ray radiation to create cross-sectional images. Dual-energy CT acquisition includes the images acquired from an alternating voltage of X-ray tube: a low- and a high-peak kilovoltage. The main objective of this study is to determine the best slice thickness that reduces image noise with adequate diagnostic information using dual energy CT head protocol. The study used the ImageJ software and statistical analyses to aid the medical image analysis of dual-energy CT. In this study, ImageJ software and F-test were utilised as the combination methods to analyse DICOM CT images. They were used to investigate the effect of slice thickness on noise and visibility in dual-energy CT head protocol images. Catphan-600 phantom was scanned at different slice thickness values;.6, 1, 2, 3, 4, 5 and 6 mm, then quantitative analyses were carried out. The DECT operated in helical mode with another fixed scan parameter values. Based on F-test statistical analyses, image noise at 0.6, 1, and 2 mm were significantly different compared to the other images acquired at slice thickness of 3, 4, 5, and 6 mm. However, no significant differences of image noise were observed at 3, 4, 5, and 6 mm. As a result, better diagnostic image value, image visibility, and lower image noise in dual-energy CT head protocol was observed at a slice thickness of 3 mm.

  17. Development of a high-speed VCSEL OCT system for real-time imaging of conscious patients larynx using a hand-held probe (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Rangarajan, Swathi; Chou, Li-Dek; Coughlan, Carolyn; Sharma, Giriraj; Wong, Brian J. F.; Ramalingam, Tirunelveli S.

    2016-02-01

    Fourier domain optical coherence tomography (FD-OCT) is a noninvasive imaging modality that has previously been used to image the human larynx. However, differences in anatomical geometry and short imaging range of conventional OCT limits its application in a clinical setting. In order to address this issue, we have developed a gradient-index (GRIN) lens rod-based hand-held probe in conjunction with a long imaging range 200 kHz Vertical-Cavity Surface Emitting Lasers (VCSEL) swept-source optical coherence tomography (SS-OCT) system for high speed real-time imaging of the human larynx in an office setting. This hand-held probe is designed to have a long and dynamically tunable working distance to accommodate the differences in anatomical geometry of human test subjects. A nominal working distance (~6 cm) of the probe is selected to have a lateral resolution <100 um within a depth of focus of 6.4 mm, which covers more than half of the 12 mm imaging range of the VCSEL laser. The maximum lateral scanning range of the probe at 6 cm working distance is approximately 8.4 mm, and imaging an area of 8.5 mm by 8.5 mm is accomplished within a second. Using the above system, we will demonstrate real-time cross-sectional OCT imaging of larynx during phonation in vivo in human and ex-vivo in pig vocal folds.

  18. Long-Term Results of Total Hip Arthroplasty with 28 millimeter Cobalt-Chromium Femoral Heads on Highly Cross-linked Polyethylene in Patients 50 years and Less

    PubMed Central

    Stambough, Jeffrey B.; Pashos, Gail; Bohnenkamp, Frank C.; Maloney, William J.; Martell, John M.; Clohisy, John C.

    2016-01-01

    Highly cross-linked polyethylene (HXLPE) is the most commonly used bearing surface in total hip arthroplasty (THA) because of its superior wear properties, but long-term results in young patients are limited. We report on the clinical outcome, radiographic wear patterns and survivorship of 72 patients ≤50 years old who had a 28-millimeter cobalt-chromium femoral head on HXLPE acetabular liner. Mean and median true linear wear rates at average ten-year follow-up were 0.0104 and 0.016 mm per year +/− 0.07 mm. Mean and median two-dimensional volumetric wear rates were 12.79 mm3 and 5.834 mm3 per year +/− 26.1mm3 as determined by Martell analysis. As a result of the minimal wear profile, there was no evidence of radiographic osteolysis and no wear-related revisions. PMID:26260785

  19. Aluminium localization in root tips of the aluminium-accumulating plant species buckwheat (Fagopyrum esculentum Moench)

    PubMed Central

    Klug, Benjamin; Specht, André; Horst, Walter J.

    2011-01-01

    Aluminium (Al) uptake and transport in the root tip of buckwheat is not yet completely understood. For localization of Al in root tips, fluorescent dyes and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) were compared. The staining of Al with morin is an appropriate means to study qualitatively the radial distribution along the root tip axis of Al which is complexed by oxalate and citrate in buckwheat roots. The results compare well with the distribution of total Al determined by LA-ICP-MS which could be reliably calibrated to compare with Al contents by conventional total Al determination using graphite furnace atomic absorption spectrometry. The Al localization in root cross-sections along the root tip showed that in buckwheat Al is highly mobile in the radial direction. The root apex predominantly accumulated Al in the cortex. The subapical root section showed a homogenous Al distribution across the whole section. In the following root section Al was located particularly in the pericycle and the xylem parenchyma cells. With further increasing distance from the root apex Al could be detected only in individual xylem vessels. The results support the view that the 10 mm apical root tip is the main site of Al uptake into the symplast of the cortex, while the subapical 10–20 mm zone is the main site of xylem loading through the pericycle and xylem parenchyma cells. Progress in the better molecular understanding of Al transport in buckwheat will depend on the consideration of the tissue specificity of Al transport and complexation. PMID:21831842

  20. Corrosion resistance of cast irons and titanium alloys as reference engineered metal barriers for use in basalt geologic storage: a literature assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Charlot, L.A.; Westerman, R.E.

    A survey and assessment of the literature on the corrosion resistance of cast irons and low-alloy titanium are presented. Selected engineering properties of cast iron and titanium are briefly described; however, the corrosion resistance of cast iron and titanium in aqueous solutions or in soils and their use in a basalt repository are emphasized. In evaluating the potential use of cast iron and titanium as structural barrier materials for long-lived nuclear waste packages, it is assumed that titanium has the general corrosion resistance to be used in relatively thin cross sections whereas the cost and availability of cast iron allowsmore » its use even in very thick cross sections. Based on this assumption, the survey showed that: The uniform corrosion of low-alloy titanium in a basalt environment is expected to be extremely low. A linear extrapolation of general corrosion rates with an added corrosion allowance suggests that a 3.2- to 6.4-mm-thick wall may have a life of 1000 yr. Pitting and crevice corrosion are not likely corrosion modes in basalt ground waters. It is also unlikely that stress corrosion cracking (SCC) will occur in the commercially pure (CP) titanium alloy or in palladiumor molybdenum-alloyed titanium materials. Low-alloy cast irons may be used as barrier metals if the environment surrounding the metal keeps the alloy in the passive range. The solubility of the corrosion product and the semipermeable nature of the oxide film allow significant uniform corrosion over long time periods. A linear extrapolation of high-temperature corrosion rates on carbon steels and corrosion rates of cast irons in soils gives an estimated metal penetration of 51 to 64 mm after 1000 yr. A corrosion allowance of 3 to 5 times that suggests that an acceptable cast iron wall may be from 178 to 305 mm thick. Although they cannot be fully assessed, pitting and crevice corrosion should not affect cast iron due to the ground-water chemistry of basalt.« less

Top