Single crystal growth of submillimeter diameter sapphire tube by the micro-pulling down method
NASA Astrophysics Data System (ADS)
Kamada, Kei; Murakami, Rikito; Kochurikhin, Vladimir V.; Luidmila, Gushchina; Jin Kim, Kyoung; Shoji, Yasuhiro; Yamaji, Akihiro; Kurosawa, Shunsuke; Ohashi, Yuji; Yokota, Yuui; Yoshikawa, Akira
2018-06-01
This paper addresses several aspects of the μ-PD growth technology as applied to submillimeter diameter sapphire tubes for UFD application. The μ-PD method has been successfully adapted for single crystal sapphire tube growth. A compound crucible made possible the growth of single crystal sapphire tube as small as around 0.70-0.72 mm in outer diameter and 0.28-0.29 in inner diameter over 160 mm in length at growth rate of 2-4 mm/min along 〈0 0 1〉 direction. An Ir crucible with a die composed of an equivalent hole and Ir wire was heated by RF coil in N2 atmosphere. The μ-PD method has been successfully adapted for single crystal sapphire tube growth. Grown crystal tube showed good XRC value of 30.2 arcsec.
Experimental investigation of two-phase flow patterns in minichannels at horizontal orientation
NASA Astrophysics Data System (ADS)
Saljoshi, P. S.; Autee, A. T.
2017-09-01
Two-phase flow is the simplest case of multiphase flow in which two phases are present for a pure component. The mini channel is considered as diameter below 3.0-0.2 mm and conventional channel is considered diameter above 3.0 mm. An experiment was conducted to study the adiabatic two-phase flow patterns in the circular test section with inner diameter of 1.1, 1.63, 2.0, 2.43 and 3.0 mm for horizontal orientation using air and water as a fluid. Different types of flow patterns found in the experiment. The parameters that affect most of these patterns and their transitions are channel size, phase superficial velocities (air and liquid) and surface tension. The superficial velocity of liquid and gas ranges from 0.01 to 66.70 and 0.01 to 3 m/s respectively. Two-phase flow pattern photos were recorded using a high speed CMOS camera. In this experiment different flow patterns were identified for different tube diameters that confirm the diameter effect on flow patterns in two-phase flows. Stratified flow was not observed for tube diameters less than 3.0 mm. Similarly, wavy-annular flow pattern was not observed in 1.6 and 1.0 mm diameter tubes due to the surface-tension effect and decrease in tube diameter. Buoyancy effects were clearly visible in 2.43 and 3.0 mm diameter tubes flow pattern. It has also observed that as the test-section diameter decreases the transition lines shift towards the higher gas and liquid velocity. However, the result of flow pattern lines in the present study has good agreement with the some of the existing flow patterns maps.
May, T.W.; Wiedmeyer, Ray H.
1998-01-01
The CETAC ADX-500 autodiluter system was tested with ELAN?? v 2.1 software and the ELAN 6000 ICP-MS instrument to determine on-line automated dilution performance during analysis of standard solutions containing nine analytes representative of the mass spectral range (mass 9 to mass 238). Two or more dilution schemes were tested for each of 5 test tube designs. Dilution performance was determined by comparison of analyte concentration means of diluted and non-diluted standards. Accurate dilutions resulted with one syringe pump addition of diluent in small diameter round-bottomed (13 mm OD) or conical-tipped (18 mm OD) tubes and one or more syringe pump additions in large diameter (28 mm OD) conical-tipped tubes. Inadequate dilution mixing which produced high analyte concentration means was observed for all dilutions conducted in flat-bottomed tubes, and for dilutions requiring multiple syringe additions of diluent in small diameter round-bottomed and conical tipped tubes. Effective mixing of diluted solutions was found to depend largely upon tube diameter and liquid depth: smaller tube diameters and greater liquid depth resulted in ineffective mixing, whereas greater tube diameter and shallower liquid depth facilitated effective mixing. Two design changes for the autodiluter were suggested that would allow effective mixing to occur using any dilution scheme and tube design.
NASA Astrophysics Data System (ADS)
Kitazaki, Satoshi; Hayashi, Nobuya
2009-10-01
Oxygen and water vapor plasmas inside a narrow long tube were produced using an AC HV glow discharge at low pressure in order to sterilize the inner surface of a tube. In order to produce plasma inside a narrow tube, an AC high voltage was adopted. The material of the tube used in this experiment was silicon rubber. The length and diameter of the tubes ranged from 300 to 1,000 mm and from 1 to 4 mm, respectively. The tube was placed in a stainless steel vacuum chamber and was evacuated to 10 Pa using a rotary pump. The material gas for plasma and radical productions was pure oxygen or water vapor, which was introduced to the chamber from a gas cylinder or water reservoir. Light emission spectral lines of oxygen and OH radicals were observed at 777 nm and 306 nm, respectively. The chemical indicator was inserted into the tube and turned to a yellowish color (from the original red) after a treatment, which indicates the generation of sufficient oxygen on OH radicals for sterilization. A tube with the length of 500 mm and diameter of 4 mm is sterilized using oxygen plasma by 10 minutes treatment. Also a tube with the length of 300 mm and diameter of 2 mm is sterilized using water vapor plasma by 5 minutes treatment.
A comparison of the CHF between tubes and annuli under PWR thermal-hydraulic conditions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herer, C.; Souyri, A.; Garnier, J.
1995-09-01
Critical Heat Flux (CHF) tests were carried out in three tubes with inside diameters of 8, 13, and 19.2 mm and in two annuli with an inner tube of 9.5 mm and an outer tube of 13 or 19.2 mm. All axial heat flux distributions in the test sections were uniform. The coolant fluid was Refrigerant 12 (Freon-12) under PWR thermal-hydraulic conditions (equivalent water conditions - Pressure: 7 to 20 MPa, Mass Velocity: 1000 to 6000 kg/m2/s, Local Quality: -75% to +45%). The effect of tube diameter is correlated for qualities under 15%. The change from the tube to themore » annulus configuration is correctly taken into account by the equivalent hydraulic diameter. Useful information is also provided concerning the effect of a cold wall in an annulus.« less
Plumbing Fixture for a Microfluidic Cartridge
NASA Technical Reports Server (NTRS)
Francis, Kevin
2007-01-01
A fixture has been devised for making the plumbing connections between a microfluidic device in a replaceable cartridge and an external fluidic system. The fixture includes a 0.25-in. (6.35-mm) thick steel plate, to which the cartridge is fastened by two 10-32 thumb screws. The plate holds one plumbing fitting for the inlet and one for the outlet of the microfluidic device. Each fitting includes a fused-silica tube of 0.006-in. (approx.0.15-mm) inside diameter within a fluorinated ethylene-propylene (FEP) tube of 0.0155-in. (approx.0.39-mm) inside diameter and 0.062- in. (approx.1.57-mm) outside diameter. The FEP tube is press-fit through the steel plate so that its exposed end is flush with the surface of the plate, and the silica tube protrudes 0.03 in. (approx.0.76 mm) from the plate/FEP-tube-end surface. The cartridge includes a glass cover plate that contains 0.06-mm-wide access ports. When the cartridge is fastened to the steel plate, the silica tubes become inserted through the access ports and into the body of the cartridge, while the ends of the FEP tubes become butted against the glass cover plate. An extremely tight seal is thereby made.
NASA Astrophysics Data System (ADS)
Kuwahara, Ken; Higashiiu, Shinya; Ito, Daisuke; Koyama, Shigeru
This paper deals with the experimental study on cooling heat transfer of supercritical carbon dioxide inside micro-fin tubes. The geometrical parameters in micro-fin tubes used in the present study are 6.02 mm in outer diameter, 4.76 mm to 5.11 mm in average inner diameter, 0.15 mm to 0.24 mm in fin height, 5 to 25 in helix angle, 46 to 52 in number of fins and 1.4 to 2.3 in area expansion ratio. Heat transfer coefficients were measured at 8-10 MPa in pressure, 360-690 kg/(m2•s) in mass velocity and 20-75 °C in CO2 temperature. The measured heat transfer coefficients of micro-fin tubes were 1.4 to 2 times higher than those of the smooth tube having 4.42 in inner diameter. The predicted heat transfer coefficients using the correlation equation, which was developed for single-phase turbulent fluid flow inside micro-fin-tubes, showed large deviations to the measured values. The new correlation to predict cooling heat transfer coefficient of supercritical carbon dioxide inside micro-fin tubes was developed taking into account the shape of fins based on experimental data empirically. This correlation equation agreed within ±20% of almost all of the experimental data.
Probe for Sampling of Interstitial Fluid From Bone
NASA Technical Reports Server (NTRS)
Janle, Elsa M.
2004-01-01
An apparatus characterized as both a membrane probe and a bone ultrafiltration probe has been developed to enable in vivo sampling of interstitial fluid in bone. The probe makes it possible to measure the concentration of calcium and other constituents of the fluid that may be relevant to bone physiology. The probe could be especially helpful in experimental studies of microgravitational bone loss and of terrestrial bone-loss disease states, including osteoporosis. The probe can be implanted in the bone tissue of a living animal and can be used to extract samples of the interstitial bone fluid from time to time during a long-term study. The probe includes three 12-cm-long polyacrylonitrile fibers configured in a loop form and attached to polyurethane tubing [inside diameter 0.025 in. (0.64 mm), outside diameter 0.040 in. (1 mm)]; the attachment is made by use of a 1-cm-long connecting piece of polyurethane tubing [inside diameter 0.035 0.003 in. (0.89 0.08 mm), outside diameter 0.060 0.003 in. (1.52 0.08 mm)]. At the distal end, a 2-cm-long piece of polyurethane tubing of the same inner and outer diameters serves as a connector to a hub. A 1-cm long piece of expanded poly (tetrafluoroethylene) tubing over the joint between the fibers and the connecting tubing serves as a tissue-in-growth site.
A novel investigation of heat transfer characteristics in rifled tubes
NASA Astrophysics Data System (ADS)
Jegan, C. Dhayananth; Azhagesan, N.
2018-05-01
The experimental investigation of heat transfer of water flowing in a rifled tube was explored at different pressures and at various operating conditions in a rifled tube heat exchanger. The specifications for the inner and outer diameters of the inner tube are 25.8 and 50.6 mm, respectively. The working fluids used in shell side and tube side are cold and hot water. The rifled tube was made of the stainless steel with 4 ribs, 50.6 mm outer diameter, 0.775 mm rib height, 58o helix angle and the length 1500 mm. The effect of pressure, wall heat flux and friction factor were discussed. The results confirm that even at low pressures the rifled tubes has an obvious enhancement in heat transfer compared with smooth tube. Results depicts that the Nusselt number increases with Reynolds number and the friction factor decreases with increase in Reynolds number and the heat transfer rate is higher for the rifled tube when compared to smooth tube, because of strong swirl flow due to centrifugal action. It also confirms that, the friction factor obtained from the rifled tube is significantly higher than that of smooth tube.
NASA Technical Reports Server (NTRS)
Uz, Mehmet; Titran, Robert H.
1993-01-01
Microstructure of Nb-1Zr-0.1C tubes were characterized as affected by extrusion temperature of the tube shell and its thermomechanical processing to tubing. Two tube shells of about 40-mm outside diameter (OD) and 25-mm inside diameter (ID) were extruded 8:1 from a vacuum arc-melted ingot at 1900 and 1550 K. Two different OD tubes of approximately 0.36-mm wall thickness were fabricated from each tube shell by a series of 26 cold drawing operations with two in process anneals. The microstructure of tube shells and the tubing before and after a 2-step heat treatment were characterized. Residue extracted chemically from each sample was also analyzed to identify the precipitates. The results concerning the effect of the initial extrusion temperature and subsequent processing on the microstructure of the tubes are presented together with a review of results from similar work on Nb-1Zr-0.1C sheet stock.
A new disruption mitigation valve (DMV) and gas flow in guiding tubes of different diameter
NASA Astrophysics Data System (ADS)
Finken, K. H.; Lehnen, M.; Bozhenkov, S. A.
2011-03-01
A new disruption mitigation valve, the DMV-30, has been developed and tested. The orifice output area of the valve is a factor of 2.4 and 12.25 times larger than that of its predecessors, DMV-20 and DMV-10, and the gas reservoir amounts to 1.3 L while the older version used at JET had only 0.65 L. The coil which provides the magnetic field pulse for the activation of the piston by an eddy current is outside of the working gas volume such that all gas volumes are now made of stainless steel. The valve has the advantages of the previous developments: it is robust and reproducible, opens fully within 3 ms and releases 50% of the gas within about 5 ms (He) to 10 ms (Ar). The valve is attached subsequently to two different guiding tubes, one with an inner diameter of 38 mm as used presently at JET and one with 102 mm inner diameter; the aim of this paper is the analysis of the gas flows for different diameters. The front of the gas pulse propagates with a Mach number of about 2.5 through the tubes, independent of the two diameters. This high speed agrees with theoretical expectations of flow expansion of a half infinite tube in vacuum. In the quasi-stationary phase of the expansion, the gas flows with about sound speed in the 102 mm tube and with about half of the sound speed in the 38 mm tube.
Effect of tracheal tube cuff shape on fluid leakage across the cuff: an in vitro study.
Dave, M H; Frotzler, A; Spielmann, N; Madjdpour, C; Weiss, M
2010-10-01
This study compared the fluid leakage in the new 'tapered' shaped against the classic 'cylindrical' shaped tracheal tube cuffs when placed in different sized tracheas. The 7.5 mm internal diameter (ID) tracheal tube cuffs-Tapered Seal Guard (TSG), Standard Seal Guard (SSG), Hi-Lo, Microcuff, Ruesch, and Portex Profile-were compared in an in vitro apparatus. Vertical artificial tracheas with 16, 20, and 22 mm ID were intubated, 5 ml clear water was applied above the unlubricated tube cuffs, and fluid leakage was measured up to 60 min. Data of tapered vs non-tapered tube cuffs (16 observations) were compared for each tracheal diameter using the Mann-Whitney test. Median (range) fluid leakage (ml) at 60 min was 2.14 (0.05-4.88), 1.14 (0.00-4.84), and 0.13 (0.00-1.32), respectively, for 16, 20, and 22 mm tracheas in the TSG tube studies when compared with 4.58 (0.44-4.88), 2.21 (0.00-4.81), and 0.00 (0.00-4.81) in the SSG tube and 4.54 (1.54-4.82), 0.90 (0.00-4.49), and 4.85 (4.40-4.99) in the Microcuff tube studies. Leakage in all polyvinylchloride (PVC) tube cuffs was almost complete (5 ml) within 5 min (P<0.001). The tapered PU tube cuff was as effective as the cylindrical PU cuffs in smaller tracheal diameters and was more efficient than the cylindrical Microcuff PU tube cuff in larger tracheal diameter in preventing subglottic fluid leakage across the tube cuff tested in this in vitro study. PVC tube cuffs leaked much more and faster than PU cuffs.
A new Doppler-echo method to quantify regurgitant volume.
Wang, S S; Rubenstein, J J; Goldman, M; Sidd, J J
1992-01-01
An in vitro technique using color flow imaging and continuous wave Doppler was developed to measure the initial regurgitant flow jet diameter and velocity integral to yield the parameters for a volume calculation. Jets were produced by volume-controlled injection through tubes of various diameters (1.3, 1.9, 2.8, and 3.5 mm) to deliver volumes from 1 to 7 ml over 100 to 300 msec at pressures from 40 to 200 mm Hg. One hundred forty-five samples were obtained. Flow jet diameter consistently overestimated tube diameter by 2 mm when injected volume was 1.5 to 7 ml and by 1.5 mm when injected volume was less than 1.5 ml. This offset was stable with various transducers (2.5, 3.5, 5.0 MHz) at normal gain setting (just under noise). Therefore, corrected flow jet diameter (FJD) = FJD - 2 mm, and Doppler volume = corrected flow jet area x velocity integral. A range of injectates from 1.1 to 7 ml generated Doppler volume of 1.0 to 8.2 ml. The relation between Doppler volume (DV) and injected volume (IV) was DV = 1.079 IV - 0.22, r2 = 0.945, p less than 0.01. This relation was not altered by tube diameter. Thus a method combining color flow imaging and continuous wave Doppler provides a reliable and accurate measure of in vitro flow volume.
Detonation re-initiation in a concentric tube arrangement for C_2H_2/O_2/Ar mixtures
NASA Astrophysics Data System (ADS)
Wu, Y.; Lee, J. H. S.; Weng, C.
2017-05-01
Re-initiation of detonation in a concentric tube arrangement where a detonation exiting from a small diameter inner tube to a large diameter outer tube has been investigated. The outer tube diameter D is 50.8 mm and inner tube diameters d are 38, 25.4, and 12.7 mm giving diameter ratios D/d=1.34, 2, and 4. Stoichiometric C_2H_2-O_2 mixtures with argon dilution of 0, 25, 50, and 70% are used in the present study. Velocity measurements are made using photodiodes, and smoked foils downstream of the exit of the inner tube are also used to record the re-initiation process. Upon exit from the inner tube, the detonation suffers an abrupt decrease in velocity and at critical conditions, the velocity downstream of the exit is of the order of 50% of the Chapman-Jouguet velocity. It is found that re-initiation generally occurs within 10 tube diameters downstream of the exit. If re-initiation is not successful, the detonation continues to propagate at a low velocity for distances of the order of 30 tube diameters without any indication of flame acceleration of deflagration-to-detonation transition (DDT). Thus, the re-initiation process is clearly defined and distinct from the usual DDT in a smooth tube. The critical d/λ value ratio in the concentric tube is significantly lower than the usual unconfined case of d/λ =13 where λ is the detonation cell size. Thus, it is a result of re-initiation at the Mach stem of the reflected shock from the wall of the outer concentric tube. If re-initiation is not successful upon the first reflection, then subsequent multiple reflections at the tube axis and wall of the outer tube can also result in re-initiation. However, this is only observed for undiluted mixtures. For high-argon-diluted mixtures, re-initiation only occurs at the Mach stem of the first reflection.
New high-precision drift-tube detectors for the ATLAS muon spectrometer
NASA Astrophysics Data System (ADS)
Kroha, H.; Fakhrutdinov, R.; Kozhin, A.
2017-06-01
Small-diameter muon drift tube (sMDT) detectors have been developed for upgrades of the ATLAS muon spectrometer. With a tube diameter of 15 mm, they provide an about an order of magnitude higher rate capability than the present ATLAS muon tracking detectors, the MDT chambers with 30 mm tube diameter. The drift-tube design and the construction methods have been optimised for mass production and allow for complex shapes required for maximising the acceptance. A record sense wire positioning accuracy of 5 μm has been achieved with the new design. In the serial production, the wire positioning accuracy is routinely better than 10 μm. 14 new sMDT chambers are already operational in ATLAS, further 16 are under construction for installation in the 2019-2020 LHC shutdown. For the upgrade of the barrel muon spectrometer for High-Luminosity LHC, 96 sMDT chambers will be contructed between 2020 and 2024.
Detonation propagation in a high loss configuration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jackson, Scott I; Shepherd, Joseph E
2009-01-01
This work presents an experimental study of detonation wave propagation in tubes with inner diameters (ID) comparable to the mixture cell size. Propane-oxygen mixtures were used in two test section tubes with inner diameters of 1.27 mm and 6.35 mm. For both test sections, the initial pressure of stoichiometric mixtures was varied to determine the effect on detonation propagation. For the 6.35 mm tube, the equivalence ratio {phi} (where the mixture was {phi} C{sub 3}H{sub 8} + 50{sub 2}) was also varied. Detonations were found to propagate in mixtures with cell sizes as large as five times the diameter ofmore » the tube. However, under these conditions, significant losses were observed, resulting in wave propagation velocities as slow as 40% of the CJ velocity U{sub CJ}. A review of relevant literature is presented, followed by experimental details and data. Observed velocity deficits are predicted using models that account for boundary layer growth inside detonation waves.« less
Tsujimoto, Yukio; Nose, Yorihito; Ohba, Kenkichi
2003-01-01
The pitot tube is a common device to measure flow velocity. If the pitot tube is used as an urodynamic catheter, urinary velocity and urethral pressure may be measured simultaneously. However, to our knowledge, urodynamic studies with the pitot tube have not been reported. We experimentally and clinically evaluated the feasibility of the pitot tube to measure urinary velocity with a transrectal ultrasound guided video urodynamic system. We carried out a basal experiment measuring flow velocity in model urethras of 4.5-8.0 mm in inner diameter with a 12-Fr pitot tube. In a clinical trial, 79 patients underwent transrectal ultrasound guided video urodynamic studies with the 12-Fr pitot tube. Urinary velocity was calculated from dynamic pressure (Pd) with the pitot tube formula and the correcting equation according to the results of the basal experiment. Velocity measured by the pitot tube was proportional to the average velocity in model urethras and the coefficients were determined by diameters of model urethras. We obtained a formula to calculate urinary velocity from the basal experiment. The urinary velocity could be obtained in 32 of 79 patients. Qmax was 8.1 +/- 4.3 mL/s (mean +/- SD; range, 18.4-1.3 mL/s), urethral diameter was 7.3 +/- 3.0 mm (mean +/- SD; range, 18.7-4.3 mm) and urinary velocity was 69.4 +/- 43.6 (mean +/- SD; range, 181.3-0 cm/s) at maximum flow rate. The correlation coefficient of Qmax measured by a flowmeter versus Qdv flow rate calculated with urethral diameter and velocity was 0.41 without significant difference. The use of the pitot tube as an urodynamic catheter to a transrectal ultrasound-guided video urodynamic system can measure urethral pressure, diameter and urinary velocity simultaneously. However, a thinner pitot tube and further clinical trials are needed to obtain more accurate results.
Sound absorption enhancement of nonwoven felt by using coupled membrane - sonic crystal inclusion
NASA Astrophysics Data System (ADS)
Fitriani, M. C.; Yahya, I.; Harjana; Ubaidillah; Aditya, F.; Siregar, Y.; Moeliono, M.; Sulaksono, S.
2016-11-01
The experimental results from laboratory test on the sound absorption performance of nonwoven felt with an array thin tubes and sonic crystal inclusions reported in this paper. The nonwoven felt sample was produced by a local company with 15 mm in its thickness and 900 gsm. The 6.4 mm diameter plastic straw was used to construct the thin tubes array while the sonic crystal is arranged in a 4 × 4 lattice crystal formation. It made from a PVC cylinder with 17 mm and 50 mm in diameter and length respectively. All cylinders have two holes positioned on 10 mm and 25 mm from the base. The results show that both treatments, array of thin tube and sonic crystal inclusions are effectively increased the sound absorption coefficient of the nonwoven felt significantly especially in the low frequency range starting from 200Hz.
A digital miniature x-ray tube with a high-density triode carbon nanotube field emitter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeong, Jin-Woo; Kang, Jun-Tae; Choi, Sungyoul
2013-01-14
We have fabricated a digital miniature x-ray tube (6 mm in diameter and 32 mm in length) with a high-density triode carbon nanotube (CNT) field emitter for special x-ray applications. The triode CNT emitter was densely formed within a diameter of below 4 mm with the focusing-functional gate. The brazing process enables us to obtain and maintain a desired vacuum level for the reliable electron emission from the CNT emitters after the vacuum packaging. The miniature x-ray tube exhibited a stable and reliable operation over 250 h in a pulse mode at an anode voltage of above 25 kV.
Performance evaluation of cross-flow single-phase liquid-to-gas polymer tube heat exchanger
NASA Astrophysics Data System (ADS)
Dewanjee, Sujan; Hossain, Md. Rakibul; Rahman, Md. Ashiqur
2017-06-01
Reduced core weight and material cost, higher corrosion resistance are some of the major eye catching properties to study polymers over metal in heat exchanger applications in spite of the former's relatively low thermal conductivity and low strength. In the present study, performance of polymer parallel thin tube heat exchanger is numerically evaluated for cross flow liquid to air applications for a wide range of design and operating parameters such as tube diameter, thickness, fluid velocity and temperature, etc. using Computational Fluid Dynamics (CFD). Among a range of available polymeric materials, those with a moderate to high thermal conductivity and strength are selected for this study. A 90 cm × 1 cm single unit of polymer tubes, with appropriate number of tubes such that at least a gap of 5 mm is maintained in between the tubes, is used as a basic unit and multiple combination in the transverse direction of this single unit is simulated to measure the effect. The tube inner diameter is varied from 2 mm to 4 mm and the pressure drop is measured to have a relative idea of pumping cost. For each inner diameter the thickness is varied from .5 mm to 2.5 mm. The water velocity and the air velocity are varied from 0.4 m/s to 2 m/s and 1 m/s to 5 m/s, respectively. The performance of the polymer heat exchanger is compared with that of metal heat exchanger through and an optimum design for polymer heat exchanger is sought out.
The structure optimization of gas-phase surface discharge and its application for dye degradation
NASA Astrophysics Data System (ADS)
Ying, CAO; Jie, LI; Nan, JIANG; Yan, WU; Kefeng, SHANG; Na, LU
2018-05-01
A gas-phase surface discharge (GSD) was employed to optimize the discharge reactor structure and investigate the dye degradation. A dye mixture of methylene blue, acid orange and methyl orange was used as a model pollutant. The results indicated that the reactor structure of the GSD system with the ratio of tube inner surface area and volume of 2.48, screw pitch between a high-voltage electrode of 9.7 mm, high-voltage electrode wire diameter of 0.8 mm, dielectric tube thickness of 2.0 mm and tube inner diameter of 16.13 mm presented a better ozone (O3) generation efficiency. Furthermore, a larger screw pitch and smaller wire diameter enhanced the O3 generation. After the dye mixture degradation by the optimized GSD system, 73.21% and 50.74% of the chemical oxygen demand (COD) and total organic carbon removal rate were achieved within 20 min, respectively, and the biochemical oxygen demand (BOD) and biodegradability (BOD/COD) improved.
Experimental Study on Flow Boiling of Carbon Dioxide in a Horizontal Microfin Tube
NASA Astrophysics Data System (ADS)
Kuwahara, Ken; Ikeda, Soshi; Koyama, Shigeru
This paper deals with the experimental study on flow boiling heat transfer of carbon dioxide in a micro-fin tube. The geometrical parameters of micro-fin tube used in this study are 6.07 mm in outer diameter, 5.24 mm in average inner diameter, 0.256 mm in fin height, 20.4 in helix angle, 52 in number of grooves and 2.35 in area expansion ratio. Flow patterns and heat transfer coefficients were measured at 3-5 MPa in pressure, 300-540 kg/(m2s) in mass velocity and -5 to 15 °C in CO2 temperature. Flow patterns of wavy flow, slug flow and annular flow were observed. The measured heat transfer coefficients of micro-fin tube were 10-40 kW/(m2K). Heat transfer coefficients were strongly influenced by pressure.
Hexagonal Hollow Tube Based Energy Absorbing Crash Buffers for Roadside Fixed Objects
NASA Astrophysics Data System (ADS)
Uddin, M. S.; Amirah Shafie, Nurul; Zivkovic, Grad
2017-03-01
The purpose of this study was to investigate the deformation of the energy absorbing hexagonal hollow tubes in a lateral compression. The aim is to design cost effective and high energy-absorbing buffer systems, which are capable of controlling out-of-control vehicles in high-speed zones. A nonlinear quasi-static finite element analysis was applied to determine the deformation and energy absorption capacity. The main parameters in the design were diameter and wall thickness of the tubes. Experimental test simulating the lateral compressive loading on a single tube was performed. Results show that as the diameter and the thickness increase, the deformation strength increases. Hexagonal tube with diameter of 219 mm and thickness of 4 mm is shown to have the highest energy absorption capability. Compared to existing cylindrical and octagonal shapes, the hexagonal tubes show the highest energy absorption capacity. Hexagonal tubes therefore can be regarded as a potential candidate for buffer designs in high speed zones. In addition, they would be compact, cost effective and facilitate ease of installation.
Ultra-Compact Multitip Scanning Probe Microscope with an Outer Diameter of 50 mm
NASA Astrophysics Data System (ADS)
Cherepanov, Vasily; Zubkov, Evgeny; Junker, Hubertus; Korte, Stefan; Blab, Marcus; Coenen, Peter; Voigtländer, Bert
We present a multitip scanning tunneling microscope (STM) where four independent STM units are integrated on a diameter of 50 mm. The coarse positioning of the tips is done under the control of an optical microscope or an SEM in vacuum. The heart of this STM is a new type of piezoelectric coarse approach called Koala Drive which can have a diameter greater than 2.5 mm and a length smaller than 10 mm. Alternating movements of springs move a central tube which holds the STM tip or AFM sensor. This new operating principle provides a smooth travel sequence and avoids shaking which is intrinsically present for nanopositioners based on inertial motion with saw tooth driving signals. Inserting the Koala Drive in a piezo tube for xyz-scanning integrates a complete STM inside a 4 mm outer diameter piezo tube of <10 mm length. The use of the Koala Drive makes the scanning probe microscopy design ultra-compact and accordingly leads to a high mechanical stability. The drive is UHV, low temperature, and magnetic field compatible. The compactness of the Koala Drive allows building a four-tip STM as small as a single-tip STM with a drift of <0.2 nm/min and lowest resonance frequencies of 2.5 (xy) and 5.5 kHz (z). We present examples of the performance of the multitip STM designed using the Koala Drive.
A novel design for steerable instruments based on laser-cut nitinol.
Dewaele, Frank; Kalmar, Alain F; De Ryck, Frederic; Lumen, Nicolaas; Williams, Leonie; Baert, Edward; Vereecke, Hugo; Kalala Okito, Jean Pierre; Mabilde, Cyriel; Blanckaert, Bart; Keereman, Vincent; Leybaert, Luc; Van Nieuwenhove, Yves; Caemaert, Jacques; Van Roost, Dirk
2014-06-01
Omnidirectional articulated instruments enhance dexterity. In neurosurgery, for example, the simultaneous use of 2 instruments through the same endoscopic shaft remains a difficult feat. It is, however, very challenging to manufacture steerable instruments of the requisite small diameter. We present a new technique to produce such instruments by means of laser cutting. Only 3 coaxial tubes are used. The middle tube has a cutting pattern that allows the steering forces to be transmitted from the proximal to the distal end. In this way the steering part is concealed in the wall of the tube. Large diameter articulated instruments such as for laparoscopy might benefit from the excellent tip stability provided by the same economical technology. Coaxial nitinol tubes are laser-cut with a Rofin Stent Cutter in a specific pattern. The 3 tubes are assembled by sliding them over one another, forming a single composite tube. In a surgical simulator, the neurosurgical microinstruments and laparoscopic needle drivers were evaluated on surgical convenience. Simultaneous use of 2 neurosurgical instruments (1.5 mm diameter) through the same endoscopic shaft proved to be very intuitive. The tip of the steerable laparoscopic instruments (10 mm diameter) could resist a lateral force of more than 20 N. The angle of motion for either instrument was at least 70° in any direction. A new design for steerable endoscopic instruments is presented. It allows the construction in a range from microinstruments to 10-mm laparoscopic devices with excellent tip stability. © The Author(s) 2013.
[A simple apparatus for controllable drinking without leaks for laboratory rats].
Huber, D
1989-01-01
A simple device for watering laboratory rats is described. It has been made by using commercially available glass tubing (DURAN 50) with outside diameters of 8 mm, 6 mm, and 3 mm, respectively. The tubes were fused at their tips. The drinking tube is fitted to a rubber stopper at the top of a 250 ml soft polyethylene bottle. By this way water-soluble drugs can be administered to rats with high precision.
NASA Astrophysics Data System (ADS)
Shikida, M.; Naito, J.; Yokota, T.; Kawabe, T.; Hayashi, Y.; Sato, K.
2009-10-01
We developed a novel catheter-type flow sensor for measuring the aspirated- and inspired-air characteristics trans-bronchially. An on-wall in-tube thermal flow sensor is mounted inside the tube, and it is used as a measurement tool in a bronchoscope. The external diameter of the tube is less than a few mm, and therefore, it can evaluate the flow characteristics in the small bronchial region. We newly developed a fabrication process to miniaturize it to less than 2.0 mm in the external diameter by using a heat shrinkable tube. A film sensor fabricated by photolithography was inserted into the tube by hand. By applying a heat shrinking process, the film was automatically mounted on the inner wall surface, and the outer size of the tube was miniaturized to almost half its original size. The final inner and outer diameters of the tube were 1.0 mm and 1.8 mm, respectively. The relationship between the input power of the sensor and the flow rate obeyed King's equation in both forward and reverse flow conditions. The sensor output dependence on ambient temperature was also studied, and the curve obtained at 39.2 °C was used as the calibration curve in animal experiments. The sensor characteristics under reciprocating flow were studied by using a ventilator, and we confirmed that the sensor was able to measure the reciprocating flow at 2.0 Hz. Finally, we successfully measured the aspirated- and inspired-air characteristics in the air passage of a rat.
NASA Astrophysics Data System (ADS)
Son, Chang-Hyo; Oh, Hoo-Kyu
2012-11-01
The condensation heat transfer characteristics for CO2 flowing in a horizontal microfin tube were investigated by experiment with respect to condensation temperature and mass flux. The test section consists of a 2,400 mm long horizontal copper tube of 4.6 mm inner diameter. The experiments were conducted at refrigerant mass flux of 400-800 kg/m2s, and saturation temperature of 20-30 °C. The main experimental results showed that annular flow was highly dominated the majority of condensation flow in the horizontal microfin tube. The condensation heat transfer coefficient increases with decreasing saturation temperature and increasing mass flux. The experimental data were compared against previous heat transfer correlations. Most correlations failed to predict the experimental data. However, the correlation by Cavallini et al. showed relatively good agreement with experimental data in the microfin tube. Therefore, a new condensation heat transfer correlation is proposed with mean and average deviations of 3.14 and -7.6 %, respectively.
NASA Technical Reports Server (NTRS)
Mukai, E.; Otsuka, H.; Nomi, K.; Honmo, I.
1982-01-01
A rapidly illuminating fluorescent lamp 1,200 mm long and 32.5 mm in diameter with an interior conducting strip which is compatible with conventional fixtures and ballasts is described. The fluorescent lamp is composed of a linear glass tube, electrodes sealed at both ends, mercury and raregas sealed in the glass tube, a fluorescent substance clad on the inner walls of the glass tube, and a clad conducting strip extending the entire length of the glass tube in the axial direction on the inner surface of the tube.
POD- Mapping and analysis of hydroturbine exit flow dynamics
NASA Astrophysics Data System (ADS)
Kjeldsen, Morten; Finstad, Pal Henrik
2012-11-01
Pairwise radial dynamic measurements of the swirling draft tube flow have been made at the 25 MW Svorka power plant in Surnadal operating at 48% load at 6 radial and 7 angular positions. The data is analyzed with traditional methods as well as with POD. The measurements were made in the turbine draft tube/exit flow in an axial measurement plane about 1200mm downstream the turbine runner. The draft tube diameter in the measurement plane is about 1300mm. The flow rate during measurements was close to 5.8m3/s. Two probes were used; both of length Le=700 mm and made of stainless steel with an outer diameter of Do=20 mm and inner diameter Di=4mm. At the end of each probe a full bridge cylindrical KULITE xcl152, 0-3.5, was mounted. 90 seconds samples at 10 kS/s were taken. The POD analysis largely follows that of Tutkun et al. (see e.g. AIAA J., 45,5,2008). The analysis shows that 26% of the pressure pulsation energy can be addressed to azimuthal mode 1. The work has been supported by Energy Norway.
Flat-panel detector, CCD cameras, and electron-beam-tube-based video for use in portal imaging
NASA Astrophysics Data System (ADS)
Roehrig, Hans; Tang, Chuankun; Cheng, Chee-Way; Dallas, William J.
1998-07-01
This paper provides a comparison of some imaging parameters of four portal imaging systems at 6 MV: a flat panel detector, two CCD cameras and an electron beam tube based video camera. Measurements were made of signal and noise and consequently of signal-to-noise per pixel as a function of the exposure. All systems have a linear response with respect to exposure, and with the exception of the electron beam tube based video camera, the noise is proportional to the square-root of the exposure, indicating photon-noise limitation. The flat-panel detector has a signal-to-noise ratio, which is higher than that observed with both CCD-Cameras or with the electron beam tube based video camera. This is expected because most portal imaging systems using optical coupling with a lens exhibit severe quantum-sinks. The measurements of signal-and noise were complemented by images of a Las Vegas-type aluminum contrast detail phantom, located at the ISO-Center. These images were generated at an exposure of 1 MU. The flat-panel detector permits detection of Aluminum holes of 1.2 mm diameter and 1.6 mm depth, indicating the best signal-to-noise ratio. The CCD-cameras rank second and third in signal-to- noise ratio, permitting detection of Aluminum-holes of 1.2 mm diameter and 2.2 mm depth (CCD_1) and of 1.2 mm diameter and 3.2 mm depth (CCD_2) respectively, while the electron beam tube based video camera permits detection of only a hole of 1.2 mm diameter and 4.6 mm depth. Rank Order Filtering was applied to the raw images from the CCD-based systems in order to remove the direct hits. These are camera responses to scattered x-ray photons which interact directly with the CCD of the CCD-Camera and generate 'Salt and Pepper type noise,' which interferes severely with attempts to determine accurate estimates of the image noise. The paper also presents data on the metal-phosphor's photon gain (the number of light-photons per interacting x-ray photon).
A vacuum-sealed miniature X-ray tube based on carbon nanotube field emitters
NASA Astrophysics Data System (ADS)
Heo, Sung Hwan; Kim, Hyun Jin; Ha, Jun Mok; Cho, Sung Oh
2012-05-01
A vacuum-sealed miniature X-ray tube based on a carbon nanotube field-emission electron source has been demonstrated. The diameter of the X-ray tube is 10 mm; the total length of the tube is 50 mm, and no external vacuum pump is required for the operation. The maximum tube voltage reaches up to 70 kV, and the X-ray tube generates intense X-rays with the air kerma strength of 108 Gy·cm2 min-1. In addition, X-rays produced from the miniature X-ray tube have a comparatively uniform spatial dose distribution.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-29
... and its individual members, Allied Tube & Conduit, IPSCO Tubulars, Inc., Sharon Tube Company, Western Tube & Conduit Corporation, and Wheatland Tube Company (collectively, ``Petitioner''), that the... pipes and tubes, of circular cross-section, and with an outside diameter of 0.372 inches (9.45 mm) or...
Performance of an adjustable, threaded inertance tube
NASA Astrophysics Data System (ADS)
Zhou, W. J.; Pfotenhauer, J. M.; Nellis, G. F.; Liu, S. Y.
2015-12-01
The performance of the Stirling type pulse tube cryocooler depends strongly on the design of the inertance tube. The phase angle produced by the inertance tube is very sensitive to its diameter and length. Recent developments are reported here regarding an adjustable inertance device that can be adjusted in real time. The inertance passage is formed by the root of a concentric cylindrical threaded device. The depth of the threads installed on the outer screw varies. In this device, the outer screw can be rotated four and half turns. At the zero turn position the length of the passage is 1.74 m and the hydraulic diameter is 7 mm. By rotating the outer screw, the inner threaded rod engages with additional, larger depth threads. Therefore, at its upper limit of rotation, the inertance passage includes both the original 1.74 m length with 7mm hydraulic diameter plus an additional 1.86 m length with a 10 mm hydraulic diameter. A phase shift change of 24° has been experimentally measured by changing the position of outer screw while operating the device at a frequency of 60 Hz. This phase angle shift is less than the theoretically predicted value due to the presence of a relatively large leak through the thread clearance. Therefore, the distributed component model of the inertance tube was modified to account for the leak path causing the data to agree with the model. Further, the application of vacuum grease to the threads causes the performance of the device to improve substantially.
Experimental Evaluation of the Heat Sink Effect in Hepatic Microwave Ablation.
Ringe, Kristina I; Lutat, Carolin; Rieder, Christian; Schenk, Andrea; Wacker, Frank; Raatschen, Hans-Juergen
2015-01-01
To demonstrate and quantify the heat sink effect in hepatic microwave ablation (MWA) in a standardized ex vivo model, and to analyze the influence of vessel distance and blood flow on lesion volume and shape. 108 ex vivo MWA procedures were performed in freshly harvested pig livers. Antennas were inserted parallel to non-perfused and perfused (700,1400 ml/min) glass tubes (diameter 5mm) at different distances (10, 15, 20mm). Ablation zones (radius, area) were analyzed and compared (Kruskal-Wallis Test, Dunn's multiple comparison Test). Temperature changes adjacent to the tubes were measured throughout the ablation cycle. Maximum temperature decreased significantly with increasing flow and distance (p<0.05). Compared to non-perfused tubes, ablation zones were significantly deformed by perfused tubes within 15 mm distance to the antenna (p<0.05). At a flow rate of 700 ml/min ablation zone radius was reduced to 37.2% and 80.1% at 10 and 15 mm tube distance, respectively; ablation zone area was reduced to 50.5% and 89.7%, respectively. Significant changes of ablation zones were demonstrated in a pig liver model. Considerable heat sink effect was observed within a diameter of 15 mm around simulated vessels, dependent on flow rate. This has to be taken into account when ablating liver lesions close to vessels.
Miyake, Fuyu; Suga, Rika; Akiyama, Takahiro; Namba, Fumihiko
2018-04-06
Neonates, particularly premature babies, are often managed with endotracheal intubation and subsequent mechanical ventilation to maintain adequate pulmonary gas exchange. There is no consensus on the standard length of endotracheal tube. Although a short tube reduces resistance and respiratory dead space, it is believed to increase the risk of accidental extubation. There are not entirely coherent data regarding the effect of endotracheal tube length on work of breathing in infants. The aim of this study was to evaluate the impact of neonatal endotracheal tube diameter and length on the work of breathing using an infant in vitro lung model. We assessed the work of breathing index and mechanical ventilation settings with various endotracheal tube diameters and lengths using the JTR100 in vitro infant lung model. The basic parameters of the model were breathing frequency of 20 per minutes, inspiratory-expiratory ratio of 1:3, and positive end-expiratory pressure of 5 cmH 2 O. In addition, the diaphragm driving pressure to maintain the set tidal volume was measured as the work of breathing index. The JTR100 was connected to the Babylog 8000plus through the endotracheal tube. Finally, we monitored the peak inspiratory pressure generated during assist-control volume guarantee mode with a targeted tidal volume of 10-30 mL. The diaphragm driving pressure using a 2.0-mm inner diameter tube was twice as high as that using a 4.0-mm inner diameter tube. To maintain the targeted tidal volume, a shorter tube reduced both the diaphragm driving pressure and ventilator-generated peak inspiratory pressure. The difference in the generated peak inspiratory pressure between the shortest and longest tubes was 5 cmH 2 O. In our infant lung model, a shorter tube resulted in a lower work of breathing and lower ventilator-generated peak inspiratory pressure. © 2018 John Wiley & Sons Ltd.
The compression and expansion waves of the forward and backward flows: an in-vitro arterial model.
Feng, J; Khir, A W
2008-05-01
Although the propagation of arterial waves of forward flows has been studied before, that of backward flows has not been thoroughly investigated. The aim of this research is to investigate the propagation of the compression and expansion waves of backward flows in terms of wave speed and dissipation, in flexible tubes. The aim is also to compare the propagation of these waves with those of forward flows. A piston pump generated a flow waveform in the shape of approximately half-sinusoid, in flexible tubes (12 mm and 16 mm diameter). The pump produced flow in either the forward or the backward direction by moving the piston forward, in a 'pushing action' or backward, in a 'pulling action', using a graphite brushes d.c. motor. Pressure and flow were measured at intervals of 5 cm along each tube and wave speed was determined using the PU-loop method. The simultaneous measurements of diameter were also taken at the same position of the pressure and flow in the 16 mm tube. Wave intensity analysis was used to determine the magnitude of the pressure and velocity waveforms and wave intensity in the forward and backward directions. Under the same initial experimental conditions, wave speed was higher during the pulling action (backward flow) than during the pushing action (forward flow). The amplitudes of pressure and velocity in the pulling action were significantly higher than those in the pushing action. The tube diameter was approximately 20 per cent smaller in the pulling action than in the pushing action in the 16 mm tube. The compression and expansion waves resulting from the pushing and pulling actions dissipated exponentially along the travelling distance, and their dissipation was greater in the smaller than in the larger tubes. Local wave speed in flexible tubes is flow direction- and wave nature-dependent and is greater with expansion than with compression waves. Wave dissipation has an inverse relationship with the vessel diameter, and dissipation of the expansion wave of the pulling action was greater than that of the pushing action.
Tracking chamber made of 15-mm mylar drift tubes
NASA Astrophysics Data System (ADS)
Kozhin, A.; Borisov, A.; Bozhko, N.; Fakhrutdinov, R.; Plotnikov, I.
2017-05-01
We are presenting a drift chamber composed from three layers of mylar drift tubes with outer diameter 15 mm. The pipe is made of strip of mylar film 125 micrometers thick covered with aluminium from the both sides. A strip of mylar is wrapped around the mandrel. Pipe is created by ultrasonic welding. A single drift tube is self-supported structure withstanding 350 g wire tension without supports and internal overpressure. About 400 such tubes were assembled. Design, quality control procedures of the drift tubes are described. Seven chambers were glued from these tubes of 560 mm length. Each chamber consists of 3 layers, 16 tubes per layer. Several chambers were tested with cosmic rays. Results of the tests, counting rate plateau and coordinate resolution are presented.
Thermal behavior of heat-pipe-assisted alkali-metal thermoelectric converters
NASA Astrophysics Data System (ADS)
Lee, Ji-Su; Lee, Wook-Hyun; Chi, Ri-Guang; Chung, Won-Sik; Lee, Kye-Bock; Rhi, Seok-Ho; Jeong, Seon-Yong; Park, Jong-Chan
2017-11-01
The alkali-metal thermal-to-electric converter (AMTEC) changes thermal energy directly into electrical energy using alkali metals, such as sodium and potassium, as the working fluid. The AMTEC system primarily consists of beta-alumina solid electrolyte (BASE) tubes, low and high-pressure chambers, an evaporator, and a condenser and work through continuous sodium circulation, similar to conventional heat pipes. When the sodium ions pass through the BASE tubes with ion conductivity, this ion transfer generates electricity. The efficiency of the AMTEC directly depends on the temperature difference between the top and bottom of the system. The optimum design of components of the AMTEC, including the condenser, evaporator, BASE tubes, and artery wick, can improve power output and efficiency. Here, a radiation shield was installed in the low-pressure chamber of the AMTEC and was investigated experimentally and numerically to determine an optimum design for preventing radiation heat loss through the condenser and the wall of AMTEC container. A computational fluid dynamics (CFD) simulation was carried out to decide the optimum size of the low-pressure chamber. The most suitable height and diameter of the chamber were 270 mm and 180 mm, respectively, with eight BASE tubes, which were 150 mm high, 25 mm in diameter, and 105 mm in concentric diameter. Increasing the temperature ratio ( T Cond /T B ) led to high power output. The minimum dimensionless value (0.4611) for temperature ( T Cond /T B ) appeared when the radiation shield was made of 500-mesh nickel. Simulation results for the best position and shape for the radiation shield, revealed that maximum power was generated when a stainless steel shield was installed in between the BASE tubes and condenser.
Li, Li-Hua; Liang, Yi-Lin; Li, Yu; Xu, Ming-Peng; Li, Wen-Tao; Liu, Guang-Nan
2018-03-01
To compare the safety and efficacy between using a small-diameter tube-assisted bronchoscopic balloon dilatation (BBD) and the traditional BBD in the treatment of benign tracheal stenosis. A retrospective study included 58 patients with benign tracheal stenosis from August 2009 to December 2014 was made. The patients who underwent traditional BBD were divided into group A, and who underwent a small-diameter tube-assisted BBD were divided into group B. The tracheal diameter, dyspnea index and blood gas analysis results were detected before and after BBD. Efficacy and complications were evaluated after BBD. There were significant differences in oxygen saturation (PaO 2 ) during the operations comparing with before and after operations in group A (P = .005), while there was no significant difference in group B (P = .079). The tracheal diameter obviously increased (in group A, from 4.16 ± 1.43 mm to 12.47 ± 1.41 mm, P = .000; in group B: from 4.94 ± 1.59 mm to 12.61 ± 1.41 mm, P = .000). Dyspnea index obviously decreased (group A: from 3.21 ± 0.93 to 0.50 ± 0.59, P = .000; group B: from 3.24 ± 0.89 to 0.65 ± 0.69, P = .000). The immediately cure rate in both groups was 100%. Long-term effect was significantly better in group B than that in group A (85.3% vs 59.1%, P = .021), at the end of the follow-up period. Small-diameter tube-assisted BBD obtains better safety and long-term efficacy than the traditional BBD in the treatment of benign tracheal stenosis. However, close attention should be given to the risk of the adverse effects caused by carbon dioxide retention. © 2017 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Ben Ahmed, Walid; Henchiri, Mohsen; Mastouri, Amna; Slim S'himi, Najet
2018-04-01
Calcified aquatic larval cases were recognized and identified in the Pleistocene tufa masses of Jebel El Mida, Gafsa, southern Tunisia. These larval constructions belong to three main insect families: caddisflies (Trichoptera, Hydropsychidae), midges (Diptera, Chironomidae) and aquatic moths (Lepidoptera, Pyralidae) that inhabited tubes in the tufa and spun nets. Each insect community has its distinctive characteristics of larval constructions that allow their recognition. The larval constructions recognized comprise fixed and portable (for caddisflies) dwelling cases and silken retreats and feeding capture nets. These last-mentioned are almost completely eroded and only remnants are preserved. The spatial distribution of these larval cases within the tufa is not random but, rather imposed by some specific paleohydraulic conditions. It's the reason why aquatic insect larval constructions are considered as prominent tool for the reconstruction of tufa and travertine depositional environments. Chironomid fixed dwelling cases (diameters range from 0.6 mm for clustered tubes to 3 mm) indicate the deposition of tufa under lotic (flowing) or lentic (standing) water conditions. The later hydraulic condition is shared with hydropsychids with fixed retreats (0.2-4 mm in diameter). Portable case-building caddisflies (case length ranging from 5 to 20 mm, and diameter from 3 to 5 mm at the cephalic end) prefer lentic conditions and are almost completely missing in high-energy flowing water locations that are preferred by pyralids (tubes are between 5 and 10 mm long and 3 mm in diameter). These insect families benefit from inhabiting the tufa by the availability of construction materials of their cases and the necessary space for their development.
Experimental Evaluation of the Heat Sink Effect in Hepatic Microwave Ablation
Ringe, Kristina I.; Lutat, Carolin; Rieder, Christian; Schenk, Andrea; Wacker, Frank; Raatschen, Hans-Juergen
2015-01-01
Purpose To demonstrate and quantify the heat sink effect in hepatic microwave ablation (MWA) in a standardized ex vivo model, and to analyze the influence of vessel distance and blood flow on lesion volume and shape. Materials and Methods 108 ex vivo MWA procedures were performed in freshly harvested pig livers. Antennas were inserted parallel to non-perfused and perfused (700,1400 ml/min) glass tubes (diameter 5mm) at different distances (10, 15, 20mm). Ablation zones (radius, area) were analyzed and compared (Kruskal-Wallis Test, Dunn’s multiple comparison Test). Temperature changes adjacent to the tubes were measured throughout the ablation cycle. Results Maximum temperature decreased significantly with increasing flow and distance (p<0.05). Compared to non-perfused tubes, ablation zones were significantly deformed by perfused tubes within 15mm distance to the antenna (p<0.05). At a flow rate of 700ml/min ablation zone radius was reduced to 37.2% and 80.1% at 10 and 15mm tube distance, respectively; ablation zone area was reduced to 50.5% and 89.7%, respectively. Conclusion Significant changes of ablation zones were demonstrated in a pig liver model. Considerable heat sink effect was observed within a diameter of 15mm around simulated vessels, dependent on flow rate. This has to be taken into account when ablating liver lesions close to vessels. PMID:26222431
Experiments on a Miniature Hypervelocity Shock Tube
NASA Astrophysics Data System (ADS)
Tasker, Douglas; Johnson, Carl; Murphy, Michael; Lieber, Mark; MIMS Team
2013-06-01
A miniature explosively-driven shock tube, based on the Voitenko compressor design, has been designed to produce shock speeds in light gases in excess of 80 km/s. Voitenko compressors over 1 meter in diameter have been reported but here experiments on miniature shock tubes with ~1-mm bore diameters are described. In this design a 12-mm diameter explosive pellet drives a metal plate into a hemispherical gas compression chamber. Downstream from the piston a mica diaphragm separates the gas from an evacuated shock tube which is confined by a massive polymethylmethacrylate (PMMA) block. The diaphragm eventually ruptures under the applied pressure loading and the compressed gases escape into the evacuated shock tube at hyper velocities. The progress of gas shocks in the tube and bow shocks in the PMMA are monitored with an ultra-high-speed imaging system, the Shock Wave Image Framing Technique (SWIFT). The resulting time-resolved images yield two-dimensional visualizations of shock geometry and progression. By measuring both the gas and bow shocks, accurate and unequivocal measurements of shock position history are obtained. The experimental results were compared with those of hydrocode modeling to optimize the design. The first experiments were suboptimum in that the velocities were ~16 km/s. Progress with these experiments will be reported.
Eustachian tube diameter: Is it associated with chronic otitis media development?
Paltura, Ceki; Can, Tuba Selçuk; Yilmaz, Behice Kaniye; Dinç, Mehmet Emre; Develioğlu, Ömer Necati; Külekçi, Mehmet
To evaluate the effect of ET diameter on Chronic Otitis Media (COM) pathogenesis. Retrospective. Patients with unilateral COM disease are included in the study. The connection between fibrocartilaginous and osseous segments of the Eustachian Tube (ET) on axial Computed Tomography (CT) images was defined and the diameter of this segment is measured. The measurements were carried out bilaterally and statistically compared. 154 (76 (49%) male, 78 (51%) female patients were diagnosed with unilateral COM and included in the study. The mean diameter of ET was 1947mm (Std. deviation±0.5247) for healthy ears and 1788mm (Std. deviation±0.5306) for diseased ears. The statistical analysis showed a significantly narrow ET diameter in diseased ear side (p<0.01). The dysfunction or anatomical anomalies of ET are correlated with COM. Measuring of the bony diameter of ET during routine Temporal CT examination is recommended for our colleagues. Copyright © 2017 Elsevier Inc. All rights reserved.
Setup of Extruded Cementitious Hollow Tubes as Containing/Releasing Devices in Self-Healing Systems
Formia, Alessandra; Terranova, Salvatore; Antonaci, Paola; Pugno, Nicola Maria; Tulliani, Jean Marc
2015-01-01
The aim of this research is to produce self-healing cementitious composites based on the use of cylindrical capsules containing a repairing agent. Cementitious hollow tubes (CHT) having two different internal diameters (of 2 mm and 7.5 mm) were produced by extrusion and used as containers and releasing devices for cement paste/mortar healing agents. Based on the results of preliminary mechanical tests, sodium silicate was selected as the healing agent. The morphological features of several mix designs used to manufacture the extruded hollow tubes, as well as the coatings applied to increase the durability of both core and shell materials are discussed. Three-point bending tests were performed on samples produced with the addition of the above-mentioned cementitious hollow tubes to verify the self-healing effectiveness of the proposed solution. Promising results were achieved, in particular when tubes with a bigger diameter were used. In this case, a substantial strength and stiffness recovery was observed, even in specimens presenting large cracks (>1 mm). The method is inexpensive and simple to scale up; however, further research is needed in view of a final optimization. PMID:28788038
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lindsay, P. E., E-mail: Patricia.Lindsay@rmp.uhn.on.ca; Granton, P. V.; Hoof, S. van
Purpose: To compare the dosimetric and geometric properties of a commercial x-ray based image-guided small animal irradiation system, installed at three institutions and to establish a complete and broadly accessible commissioning procedure. Methods: The system consists of a 225 kVp x-ray tube with fixed field size collimators ranging from 1 to 44 mm equivalent diameter. The x-ray tube is mounted opposite a flat-panel imaging detector, on a C-arm gantry with 360° coplanar rotation. Each institution performed a full commissioning of their system, including half-value layer, absolute dosimetry, relative dosimetry (profiles, percent depth dose, and relative output factors), and characterization ofmore » the system geometry and mechanical flex of the x-ray tube and detector. Dosimetric measurements were made using Farmer-type ionization chambers, small volume air and liquid ionization chambers, and radiochromic film. The results between the three institutions were compared. Results: At 225 kVp, with 0.3 mm Cu added filtration, the first half value layer ranged from 0.9 to 1.0 mm Cu. The dose-rate in-air for a 40 × 40 mm{sup 2} field size, at a source-to-axis distance of 30 cm, ranged from 3.5 to 3.9 Gy/min between the three institutions. For field sizes between 2.5 mm diameter and 40 × 40 mm{sup 2}, the differences between percent depth dose curves up to depths of 3.5 cm were between 1% and 4% on average, with the maximum difference being 7%. The profiles agreed very well for fields >5 mm diameter. The relative output factors differed by up to 6% for fields larger than 10 mm diameter, but differed by up to 49% for fields ≤5 mm diameter. The mechanical characteristics of the system (source-to-axis and source-to-detector distances) were consistent between all three institutions. There were substantial differences in the flex of each system. Conclusions: With the exception of the half-value layer, and mechanical properties, there were significant differences between the dosimetric and geometric properties of the three systems. This underscores the need for careful commissioning of each individual system for use in radiobiological experiments.« less
NASA Astrophysics Data System (ADS)
Kustra, Piotr; Milenin, Andrij; Płonka, Bartłomiej; Furushima, Tsuyoshi
2016-06-01
Development of technological production process of biocompatible magnesium tubes for medical applications is the subject of the present paper. The technology consists of two stages—extrusion and dieless drawing process, respectively. Mg alloys for medical applications such as MgCa0.8 are characterized by low technological plasticity during deformation that is why optimization of production parameters is necessary to obtain good quality product. Thus, authors developed yield stress and ductility model for the investigated Mg alloy and then used the numerical simulations to evaluate proper manufacturing conditions. Grid Extrusion3d software developed by authors was used to determine optimum process parameters for extrusion—billet temperature 400 °C and extrusion velocity 1 mm/s. Based on those parameters the tube with external diameter 5 mm without defects was manufactured. Then, commercial Abaqus software was used for modeling dieless drawing. It was shown that the reduction in the area of 60% can be realized for MgCa0.8 magnesium alloy. Tubes with the final diameter of 3 mm were selected as a case study, to present capabilities of proposed processes.
Experimental investigations on steel-concrete composite columns for varying parameters
NASA Astrophysics Data System (ADS)
Aparna, V.; Vivek, D.; Neelima, Kancharla; Karthikeyan, B.
2017-07-01
In this study, the experimental investigations on steel tubes filled with different types of concrete are presented. Steel tubes filled with fibre reinforced concrete using lathe waste and steel tube with concerned confined with steel mesh were investigated. The combinations were compared with steel tubes with conventional concrete. A total of 4 concrete filled steel tube (CFST) combinations were made with tubes of diameter 100 mm with wall thickness 1.6 mm and a height of 300 mm. Axial compression test to examine the resisting capacity of the columns and push-out test for noting the bond strength were performed. Coupon tests were also conducted to determine the mechanical properties of steel. The structural behaviour of the composite columns was evaluated from on the test results. It was observed that steel tube filled fibre reinforced possessed better bond strength and resistance to axial load.
Taylor, Stuart A; Halligan, Steve; Bartram, Clive I; Morgan, Paul R; Talbot, Ian C; Fry, Nicola; Saunders, Brian P; Khosraviani, Kirosh; Atkin, Wendy
2003-10-01
To investigate the effects of orientation, collimation, pitch, and tube current setting on polyp detection at multi-detector row computed tomographic (CT) colonography and to determine the optimal combination of scanning parameters for screening. A colectomy specimen containing 117 polyps of different sizes was insufflated and imaged with a multi-detector row CT scanner at various collimation (1.25 and 2.5 mm), pitch (3 and 6), and tube current (50, 100, and 150 mA) settings. Two-dimensional multiplanar reformatted images and three-dimensional endoluminal surface renderings from the 12 resultant data sets were examined by one observer for the presence and conspicuity of polyps. The results were analyzed with Poisson regression and logistic regression to determine the effects of scanning parameters and of specimen orientation on polyp detection. The percentage of polyps that were detected significantly increased when collimation (P =.008) and table feed (P =.03) were decreased. Increased tube current resulted in improved detection only of polyps with a diameter of less than 5 mm. Polyps of less than 5 mm were optimally depicted with a collimation of 1.25 mm, a pitch of 3, and a tube current setting of 150 mA; polyps with a diameter greater than 5 mm were adequately depicted with 1.25-mm collimation and with either pitch setting and any of the three tube current settings. Small polyps in the transverse segment (positioned at a 90 degrees angle to the z axis of scanning) were significantly less visible than those in parallel or oblique orientations (P <.001). The effective radiation dose, calculated with a Monte Carlo simulation, was 1.4-10.0 mSv. Detection of small polyps (<5 mm) with multi-detector row CT is highly dependent on collimation, pitch, and, to a lesser extent, tube current. Collimation of 1.25 mm, combined with pitch of 6 and tube current of 50 mA, provides for reliable detection of polyps 5 mm or larger while limiting the effective radiation dose. Polyps smaller than 5 mm, however, may be poorly depicted with use of these settings in the transverse colon. Copyright RSNA, 2003
1990-12-01
is constructed from stainless steel hypodermic tubing with inner and outer diameters of 0.203 mm and 0.406 mm. The five tubes were first joined by...for all channels is 256 kHz. A schematic diagram of the measurement process [Ref. 25] is given in Figure 78, and is also described below. The analog...and smoke rake. Combustion takes place inside a 40.64 cm long, 6.27 cm inside diameter (2.5 inch schedule 40) steel pipe. Inside this chamber, smoke is
Performance data of the new free-piston shock tunnel T5 at GALCIT
NASA Technical Reports Server (NTRS)
Hornung, H.; Sturtevant, B.; Belanger, J.; Sanderson, S.; Brouillette, M.; Jenkins, M.
1992-01-01
A new free piston shock tunnel has been constructed at the Graduate Aeronautical Laboratories at Caltec. Compression tube length is 30 m and diameter 300 mm. Shock tube length is 12 m and diameter 90 mm. Piston mass is 150 kg and maximum diaphragm burst pressure is 130 MPa. Special features of this facility are that the pressure in the driver gas is monitored throughout the compression process until well after diaphragm rupture, and that the diaphragm burst pressure can be measured dynamically. An analysis of initial performance data including transient behavior of the flow over models is presented.
Seo, Yeong-Hyeon; Hwang, Kyungmin; Jeong, Ki-Hun
2018-02-19
We report a 1.65 mm diameter forward-viewing confocal endomicroscopic catheter using a flip-chip bonded electrothermal MEMS fiber scanner. Lissajous scanning was implemented by the electrothermal MEMS fiber scanner. The Lissajous scanned MEMS fiber scanner was precisely fabricated to facilitate flip-chip connection, and bonded with a printed circuit board. The scanner was successfully combined with a fiber-based confocal imaging system. A two-dimensional reflectance image of the metal pattern 'OPTICS' was successfully obtained with the scanner. The flip-chip bonded scanner minimizes electrical packaging dimensions. The inner diameter of the flip-chip bonded MEMS fiber scanner is 1.3 mm. The flip-chip bonded MEMS fiber scanner is fully packaged with a 1.65 mm diameter housing tube, 1 mm diameter GRIN lens, and a single mode optical fiber. The packaged confocal endomicroscopic catheter can provide a new breakthrough for diverse in-vivo endomicroscopic applications.
Eddy current signal comparison for tube identification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glass, S. W., E-mail: Bill.Glass@areva.com, E-mail: Ratko.Vojvodic@areva.com; Vojvodic, R., E-mail: Bill.Glass@areva.com, E-mail: Ratko.Vojvodic@areva.com
2015-03-31
Inspection of nuclear power plant steam generator tubes is required to justify continued safe plant operation. The steam generators consist of thousands of tubes with nominal diameters of 15 to 22mm, approximately 1mm wall thickness, and 20 to 30m in length. The tubes are inspected by passing an eddy current probe through the tubes from tube end to tube end. It is critical to know exactly which tube identification (row and column) is associated with each tube's data. This is controlled by a precision manipulator that provides the tube ID to the eddy current system. Historically there have been somemore » instances where the manipulator incorrectly reported the tube ID. This can have serious consequences including lack of inspection of a tube, or if a pluggable indication is detected, the tube is likely to be mis-plugged thereby risking a primary to secondary leak.« less
NASA Astrophysics Data System (ADS)
Trejo, Adrian
Rocket engine fuel alternatives have been an area of discussion for use in high performance engines and deep spaceflight missions. In particular, LCH4 has showed promise as an alternative option in regeneratively cooled rocket engines due to its non-toxic nature, similar storage temperatures to liquid oxygen, and its potential as an in situ resource. However, data pertaining to the heat transfer characteristics of LCH4 is limited. For this reason, a High Heat Transfer Test Facility (HHTTF) at the University of Texas at El Paso's (UTEP) Center for Space Exploration Technology and Research has been developed for the purpose of flowing LCH4 through several heated tube geometry designs subjected to a constant heat flux. In addition, a Methane Condensing Unit (MCU) is integrated to the system setup to supply LCH4 to the test facility. Through the use of temperature and pressure measurements, this experiment will serve not only to study the heat transfer characteristics of LCH4; it serves as a method of simulating the cooling channels of a regeneratively cooled rocket engine at a subscale level. The cross sections for the cooling channels investigated are a 1.8 mm x 1.8 mm square channel, 1.8 mm x 4.1 mm rectangular channel, 3.2 mm and 6.34 mm inside diameter channel, and a 1.8 mm x 14.2 mm high aspect ratio cooling channel (HARCC). The test facility is currently designed for test pressures between 1.03 MPa to 2.06 MPa and heat fluxes up to 5 MW/m2. Results show that at the given test pressures, the Reynolds number reaches up to 140,000 for smaller cooling channels (3.2 mm diameter tube and 1.8 mm x 4.1 mm rectangle) while larger cooling channel geometries (6.35 mm diameter and HARCC) reached Reynolds number around 70,000. Nusselt numbers reached as high as 320 and 265 for a 3.2 mm diameter tube and 1.8 mm x 4.1 mm rectangular channel respectively. For cooling channel geometries with 6.35 mm diameter and HARCC geometry, Nusselt numbers reached 136 (excluding an outlier) and 106 respectively. Heat transfer predictions applied to the data yielded theoretical correlations within 40% of the experimental data. However, typical theoretical values fall within 10%-15% of the experimental values showing agreeable correlations and supporting theories stated in the present study.
Flow regimes of adiabatic gas-liquid two-phase under rolling conditions
NASA Astrophysics Data System (ADS)
Yan, Chaoxing; Yan, Changqi; Sun, Licheng; Xing, Dianchuan; Wang, Yang; Tian, Daogui
2013-07-01
Characteristics of adiabatic air/water two-phase flow regimes under vertical and rolling motion conditions were investigated experimentally. Test sections are two rectangular ducts with the gaps of 1.41 and 10 mm, respectively, and a circular tube with 25 mm diameter. Flow regimes were recorded by a high speed CCD-camera and were identified by examining the video images. The experimental results indicate that the characteristics of flow patterns in 10 mm wide rectangular duct under vertical condition are very similar to those in circular tube, but different from the 1.41 mm wide rectangular duct. Channel size has a significant influence on flow pattern transition, boundary of which in rectangular channels tends asymptotically towards that in the circular tube with increasing the width of narrow side. Flow patterns in rolling channels are similar to each other, nevertheless, the effect of rolling motion on flow pattern transition are significantly various. Due to the remarkable influences of the friction shear stress and surface tension in the narrow gap duct, detailed flow pattern maps of which under vertical and rolling conditions are indistinguishable. While for the circular tube with 25 mm diameter, the transition from bubbly to slug flow occurs at a higher superficial liquid velocity and the churn flow covers more area on the flow regime map as the rolling period decreases.
Vinyard, Andrew; Hansen, Kaj A; Byrd, Ross; Stuart, Douglas A; Hansen, John E
2014-01-01
We report a convenient and inexpensive technique for the rapid acquisition of absorption spectra from small samples at cryogenic temperatures using a home built cryostat with novel collection optics. A cylindrical copper block was constructed with a coaxial bore to hold a 4.00 mm diameter electron paramagnetic resonance (EPR) tube and mounted on a copper feed in thermal contact with liquid nitrogen. A 6.35 mm diameter hole was bored into the side of the cylinder so a fiber optic cable bundle could be positioned orthogonally to the EPR tube. The light passing through the sample is reflected off of the opposing surfaces of the EPR tube and surrounding copper, back through the sample. The emergent light is then collected using the fiber optic bundle and analyzed using a dispersive spectrometer. Absorption spectra for KMnO4 were measured between 400 and 700 nm. Absorption intensity at 506, 525, 545, and 567 nm was found to be proportional to concentration, displaying Beer's law-like behavior. The EPR tube had an internal diameter of 3.2 mm; the double pass of the probe beam through the sample affords a central path length of about 6.4 mm. Comparing these measurements with those recorded on a conventional tabletop spectrometer using a cuvette with a 10.00 mm path length, we consistently found a ratio between intensities of 0.58 rather than the anticipated 0.64. These 6% smaller values we attribute to the curvature of the EPR tube and transmission/reflection losses. This system is particularly well-suited to studying the kinetics and dynamics of chemical reactions at cryogenic temperatures. The rapid response (100 ms) and multiplex advantage provided the opportunity of recording simultaneous time courses at several wavelengths following initiation of a chemical reaction with a pulsed laser source.
Diameter Effect Curve and Detonation Front Curvature Measurements for ANFO
NASA Astrophysics Data System (ADS)
Catanach, R. A.; Hill, L. G.
2002-07-01
Diameter effect and front curvature measurements are reported for rate stick experiments on commercially available prilled ANFO (ammonium-nitrate/fuel-oil) at ambient temperature. The shots were fired in paper tubes so as to provide minimal confinement. Diameters ranged from 77 mm (approximately failure diameter) to 205 mm, with the tube length being ten diameters in all cases. Each detonation wave shape was fit with an analytic form, from which the local normal velocity Dn, and local total curvature kappa, were generated as a function of radius R, then plotted parametrically to generate a Dn(kappa) function. The observed behavior deviates substantially from that of previous explosives, for which curves for different diameters overlay well for small kappa but diverge for large kappa, and for which kappa increases monotonically with R. For ANFO, we find that Dn(kappa) curves for individual sticks 1) show little or no overlap--with smaller sticks lying to the right of larger ones, 2) exhibit a large velocity deficit with little kappa variation, and 3) reach a peak kappa at an intermediate R.
Microvolume index of refraction determinations by interferometric backscatter
NASA Astrophysics Data System (ADS)
Bornhop, Darryl J.
1995-06-01
A new method has been applied to the determination of fluid bulk properties in small detection volumes. Through the use of an unfocused He-Ne laser beam and a cylindrical tube of capillary dimensions, relative refractive-index measurements are possible. The backscattered light from the illumination of a tube of capillary dimensions produces an interference pattern that is spatially defined and that contains information related to the bulk properties of the fluid contained in the tube. Positional changes in the intensity-modulated beam profile (interference fringes) are directly related to the refractive index of the fluid in the tube. The determination of dn/n at the 10-7 level is possible in probe volumes of 350 pL. The technique has been applied to tubes as small as 75 mu m inner diameter and as large as 1.0 mm inner diameter. No modification of the simple optical bench is required for facilitating the determination of refractive index for the complete range of tube diameters.
The fracture strength by a torsion test at the implant-abutment interface.
Watanabe, Fumihiko; Hiroyasu, Kazuhiko; Ueda, Kazuhiko
2015-12-01
Fractured connections between implants and implant abutments or abutment screws are frequently encountered in a clinical setting. The purpose of this study was to investigate fracture strength using a torsion test at the interface between the implant and the abutment. Thirty screw-type implant with diameters of 3.3, 3.8, 4.3, 5.0, and 6.0 mm were submitted to a torsion test. Implants of each size were connected to abutments with abutment screws tightened to 20 N · cm. Mechanical stress was applied with a rotational speed of 3.6 °/min until fracture occurred, and maximum torque (fracture torque) and torsional yield strength were measured. The mean values were calculated and then compared using Tukey's test. The abutments were then removed, and the implant-abutment interfaces were examined using a scanning electron microscope (SEM). No significant differences in mean fracture torque were found among 3.3, 3.8, and 4.3 mm-diameter implants, but significant differences were found between these sizes and 5.0 and 6.0 mm-diameter implants (p < 0.01). Concerning mean torsional yield strength, significant differences were found between 3.3, 3.8, and 4.3 mm-diameter and 5.0 and 6.0 mm-diameter implants (p < 0.01). Observations under the SEM showed that all the projections of the abutment corresponding to the internal notches of the implant body had been destroyed. Smaller diameter implants demonstrated lower fracture torque and torsional yield strength than implants with larger diameters. In internal tube-in-tube connections, three abutment projections corresponding to rotation-prevention notches were destroyed in each implant.
Bone formation within alumina tubes: effect of calcium, manganese, and chromium dopants.
Pabbruwe, Moreica B; Standard, Owen C; Sorrell, Charles C; Howlett, C Rolfe
2004-09-01
Alumina tubes (1.3mm outer diameter, 0.6mm inner diameter, 15 mm length) doped with Ca, Mn, or Cr at nominal concentrations of 0.5 and 5.0 mol% were implanted into femoral medullary canals of female rats for 16 weeks. Tissue formation within tubes was determined by histology and histomorphometry. Addition of Ca to alumina promoted hypertrophic bone formation at the advancing tissue fronts and tube entrances, and appeared to retard angiogenesis by limiting ongoing cellular migration into the tube. It is speculated that the presence of a secondary phase of calcium hexaluminate, probably having a solubility greater than that of alumina, possibly increased the level of extracellular Ca and, consequently, stimulated osteoclastic activity at the bone-ceramic interface. Addition of Mn significantly enhanced osteogenesis within the tubes. However, it is not possible to determine whether phase composition or microstructure of the ceramic was responsible for this because both were significantly altered by Mn addition. Addition of Cr to the alumina apparently stimulated bone remodelling as indicated by increased cellular activity and bone resorption at the tissue-implant interface. Cr was incorporated into the alumina as a solid solution and the tissue response was speculated to be an effect of surface chemistry rather than microstructure. The work demonstrates that doping a bioinert ceramic with small amounts of specific elements can significantly alter tissue ingrowth, differentiation, and osteogenesis within a porous implant.
2012-02-17
A drug delivery system (DDS) consisting of a perforated microtube ( polyimide , inside diameter= 1.8 mm, tube length= 20 mm, hole size= 0.15 mm) was... biocompatible and capable of long-term constant release of hydrophilic drugs such as sodium fluorescein.
NASA Astrophysics Data System (ADS)
Zhang, P.; Fu, X.
2009-10-01
Application of liquid nitrogen to cooling is widely employed in many fields, such as cooling of the high temperature superconducting devices, cryosurgery and so on, in which liquid nitrogen is generally forced to flow inside very small passages to maintain good thermal performance and stability. In order to have a full understanding of the flow and heat transfer characteristics of liquid nitrogen in micro-tube, high-speed digital photography was employed to acquire the typical two-phase flow patterns of liquid nitrogen in vertically upward micro-tubes of 0.531 and 1.042 mm inner diameters. It was found from the experimental results that the flow patterns were mainly bubbly flow, slug flow, churn flow and annular flow. And the confined bubble flow, mist flow, bubble condensation and flow oscillation were also observed. These flow patterns were characterized in different types of flow regime maps. The surface tension force and the size of the diameter were revealed to be the major factors affecting the flow pattern transitions. It was found that the transition boundaries of the slug/churn flow and churn/annular flow of the present experiment shifted to lower superficial vapor velocity; while the transition boundary of the bubbly/slug flow shifted to higher superficial vapor velocity compared to the results of the room-temperature fluids in the tubes with the similar hydraulic diameters. The corresponding transition boundaries moved to lower superficial velocity when reducing the inner diameter of the micro-tubes. Time-averaged void fraction and heat transfer characteristics for individual flow patterns were presented and special attention was paid to the effect of the diameter on the variation of void fraction.
NASA Astrophysics Data System (ADS)
Hata, K.; Fukuda, K.; Masuzaki, S.
2018-04-01
Twisted-tape-induced swirl-flow heat transfer due to exponentially increasing heat inputs with various exponential periods ( Q = Q 0 exp(t/τ), τ = 6.04 to 23.07 s) and twisted-tape-induced pressure drop was systematically measured for various mass velocities ( G = 4115 to 13,656 kg/m2 s), inlet liquid temperatures ( T in = 285.88 to 299.09 K), and inlet pressures ( P in = 847.45 to 943.29 kPa) using an experimental water loop flow. Measurements were made over a 59.2-mm effective length and three sections (upper, middle, and lower positions), within which four potential taps were spot-welded onto the outer surface of a 6-mm-inner-diameter, 69.6-mm-heated length, 0.4-mm-thickness platinum circular test tube. Type SUS304 twisted tapes with a width w = 5.6 mm, a thickness δ T = 0.6 mm, a total length l = 372 mm, and twist ratios y = 2.39 and 4.45 were employed in this study. The RANS equations (Reynolds Averaged Navier-Stokes Simulation) with a k-ɛ turbulence model for a circular tube 6 mm in diameter and 636 mm in length were numerically solved for heating of water with a heated section 6 mm in diameter and 70 mm in length using the CFD code, under the same conditions as the experimental ones and considering the temperature dependence of the thermo-physical properties concerned. The theoretical values of surface heat flux q on the circular tubes with twisted tapes with twist ratios y of 2.39 and 4.45 were found to be almost in agreement with the corresponding experimental values of heat flux q, with deviations of less than 30% for the range of temperature difference between the average heater inner surface temperature and the liquid bulk mean temperature ΔT L [ = T s,av - T L , T L = ( T in + T out )/2] considered in this study. The theoretical values of the local surface temperature T s , local average liquid temperature T f,av , and local liquid pressure drop ΔP x were found to be within almost 15% of the corresponding experimental ones. The thickness of the conductive sub-layer δ CSL and the nondimensional thickness of the conductive sub-layer y + CSL on the circular tubes with various twisted-tape inserts were determined on the basis of numerical solutions for the swirl velocities u sw ranging from 5.23 to 21.18 m/s. Correlations between the conductive sub-layer thickness δ CSL and the nondimensional thickness of the conductive sub-layer y + CSL for twisted-tape-induced swirl-flow heat transfer in a vertical circular tube were derived.
Spicher, G; Borchers, U
1984-10-01
The series of tests described in a preceding publication (Spicher and Borchers, 1983) has been continued in a modified way. This time, the dependency of the microbiological test results of a formaldehyde gas sterilization procedure on length and inner diameter of the tubes serving as test pieces was examined. The tubes were 1 or 2 m in length with an inner diameter of 1 or 2 mm. The tests were performed with four different preparations of bioindicators. Spores of Bac. stearothermophilus served as test germs. The preparations differed in the type of suspension used for the preparation of the bioindicators: distilled water, diluted blood (10%), undiluted blood, 10% albumin solution. The spore suspensions had been dried on linen thread. During the test procedure, the bioindicators were located near the sealed end of the tube. After completion of the sterilization procedure, the bioindicators were examined for viable germs. In tubes of identical length, the frequency of indicators carrying viable germs was always higher in those of 1 mm than in those of 2 mm inner diameter. In tubes of identical inner diameter, the frequency of indicators carrying viable germs in those of 2 m length was always higher than in those of 1 m length. This regularity was independent of the type of bioindicators used. The bioindicators for the preparation of which a 10% albumin solution had been employed showed the highest resistance. A somewhat lower resistance was found for the bioindicators prepared with undiluted blood. The bioindicators for which the spores had been suspended in diluted blood proved to have the lowest resistance. If the spores had been suspended in distilled water, the resistance of the bioindicators was a little lower than that of those suspended in undiluted blood, but was higher than that of the dried spores with diluted blood. The test results confirm the effectiveness of the method proposed earlier, i.e. to deposit the bioindicators in special test pieces (e.g. tubes or sounds) for the microbiological testing of formaldehyde gas sterilization procedures. These test pieces must be at least as long and as narrow as the longest and narrowest cavity of the object to be sterilized (tubes, catheters). In order to standardize the microbiological testing of formaldehyde gas sterilization procedures and to guarantee a certain minimum efficiency, the bioindicator as well as the test piece and its size (length and inner diameter) should be standardized.(ABSTRACT TRUNCATED AT 400 WORDS)
NASA Astrophysics Data System (ADS)
Bae, Kyung Jin; Cha, Dong An; Kwon, Oh Kyung
2016-11-01
The objectives of this paper are to develop correlations between heat transfer and pressure drop for oval finned-tube heat exchanger with large diameters (larger than 20 mm) used in a textile machine dryer. Numerical tests using ANSYS CFX are performed for four different parameters; tube size, fin pitch, transverse tube pitch and longitudinal tube pitch. The numerical results showed that the Nusselt number and the friction factor are in a range of -16.2 ~ +3.1 to -7.7 ~ +3.9 %, respectively, compared with experimental results. It was found that the Nusselt number linearly increased with increasing Reynolds number, but the friction factor slightly decreased with increasing Reynolds number. It was also found that the variation of longitudinal tube pitch has little effect on the Nusselt number and friction factor than other parameters (below 2.0 and 2.5 %, respectively). This study proposed a new Nusselt number and friction factor correlation of the oval finned-tube heat exchanger with large diameters for textile machine dryer.
Experimental study on flow boiling heat transfer of LNG in a vertical smooth tube
NASA Astrophysics Data System (ADS)
Chen, Dongsheng; Shi, Yumei
2013-10-01
An experimental apparatus is set up in this work to study the upward flow boiling heat transfer characteristics of LNG (liquefied natural gas) in vertical smooth tubes with inner diameters of 8 mm and 14 mm. The experiments were performed at various inlet pressures from 0.3 to 0.7 MPa. The results were obtained over the mass flux range from 16 to 200 kg m-2 s-1 and heat fluxes ranging from 8.0 to 32 kW m-2. The influences of quality, heat flux and mass flux, tube diameter on the heat transfer characteristic are examined and discussed. The comparisons of the experimental heat transfer coefficients with the predicted values from the existing correlations are analyzed. The correlation by Zou et al. [16] shows the best accuracy with the RMS deviation of 31.7% in comparison with the experimental data.
Computed Tomographic Window Setting for Bronchial Measurement to Guide Double-Lumen Tube Size.
Seo, Jeong-Hwa; Bae, Jinyoung; Paik, Hyesun; Koo, Chang-Hoon; Bahk, Jae-Hyon
2018-04-01
The bronchial diameter measured on computed tomography (CT) can be used to guide double-lumen tube (DLT) sizes objectively. The bronchus is known to be measured most accurately in the so-called bronchial CT window. The authors investigated whether using the bronchial window results in the selection of more appropriately sized DLTs than using the other windows. CT image analysis and prospective randomized study. Tertiary hospital. Adults receiving left-sided DLTs. The authors simulated selection of DLT sizes based on the left bronchial diameters measured in the lung (width 1,500 Hounsfield unit [HU] and level -700 HU), bronchial (1,000 HU and -450 HU), and mediastinal (400 HU and 25 HU) CT windows. Furthermore, patients were randomly assigned to undergo imaging with either the bronchial or mediastinal window to guide DLT sizes. Using the underwater seal technique, the authors assessed whether the DLT was appropriately sized, undersized, or oversized for the patient. On 130 CT images, the bronchial diameter (9.9 ± 1.2 mm v 10.5 ± 1.3 mm v 11.7 ± 1.3 mm) and the selected DLT size were different in the lung, bronchial, and mediastinal windows, respectively (p < 0.001). In 13 patients (17%), the bronchial diameter measured in the lung window suggested too small DLTs (28 Fr) for adults. In the prospective study, oversized tubes were chosen less frequently in the bronchial window than in the mediastinal window (6/110 v 23/111; risk ratio 0.38; 95% CI 0.19-0.79; p = 0.003). No tubes were undersized after measurements in these two windows. The bronchial measurement in the bronchial window guided more appropriately sized DLTs compared with the lung or mediastinal windows. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Wei, Chenwei; Xia, Jinjun; Pelivanov, Ivan; Hu, Xiaoge; Gao, Xiaohu; O'Donnell, Matthew
2012-02-01
Trapping and manipulation of micro-scale objects mimicking metastatic cancer cells in a flow field have been demonstrated with magnetomotive photoacoustic (mmPA) imaging. Coupled contrast agents combining gold nanorods (15 nm × 50 nm; absorption peak around 730 nm) with 15 nm diameter magnetic nanospheres were targeted to 10 μm polystyrene beads recirculating in a 1.6 mm diameter tube mimicking a human peripheral vessel. Targeted objects were then trapped by an external magnetic field produced by a dual magnet system consisting of two disc magnets separated by 6 cm to form a polarizing field (0.04 Tesla in the tube region) to magnetize the magnetic contrast agents, and a custom designed cone magnet array with a high magnetic field gradient (about 0.044 Tesla/mm in the tube region) producing a strong trapping force to magnetized contrast agents. Results show that polystyrene beads linked to nanocomposites can be trapped at flow rates up to 12 ml/min. It is shown that unwanted background in a photoacoustic image can be significantly suppressed by changing the position of the cone magnet array with respect to the tube, thus creating coherent movement of the trapped objects. This study makes mmPA imaging very promising for differential visualization of metastatic cells trafficking in the vasculature.
PCL-PGLA composite tubular scaffold preparation and biocompatibility investigation.
Mo, X; Weber, H-J; Ramakrishna, S
2006-08-01
The objective of this paper was to fabricate a biodegradable tubular scaffold for small diameter (d<6 mm) blood vessel tissue engineering. The tube scaffold needed a porous wall for cell attachment, proliferation and tissue regeneration with its degradation. A novel method given in this paper was to coat a porous layer of poly (epsilon-caprolactone) (PCL) on the outside of a poly (glycolic-co-lactic acid) (PGLA with GA:LA=90:10) fiber braided tube to give a PCL-PGLA composite. The PGLA tube was fabricated using a braiding machine by inserting a Teflon tube with the desired diameter in center of the 20 spindles, which are the carriers of PGLA fibers. Changing the diameter of the Teflon tube can vary the inner diameter of a braided PGLA tube. Thermally induced phase separation method was used for PCL solution coating on the surface of the PGLA braided tube. Controlling the polymer concentration, non-solvent addition and quenching temperature generated the pore structures, with pore sizes ranging from 10-30 microm. The fibroblast cells were seeded on the tubular scaffold and cultured in vitro for the biocompatibility investigation. Histology results showed that the fibroblast cells proliferated on the interconnected pore of the PCL porous layer in 1 week.
Piezoelectric ultrasonic micromotor with 1.5 mm diameter.
Dong, Shuxiang; Lim, Siak P; Lee, Kwork H; Zhang, Jingdong; Lim, Leong C; Uchino, Kenji
2003-04-01
A piezoelectric ultrasonic micromotor has been developed using a lead zirconate titanate (PZT) ceramic/metal composite tube stator that was 1.5 mm in diameter and 7 mm in length. The micromotor was operated in its first bending vibration mode (approximately 70 kHz), producing speeds from hundreds to over 2000 rpm in both rotational directions. The maximum torque-output was 45 microN-m, which is far superior to previous PZT thin film-based micromotors. This micromotor showed good reliability and stability for more than 300 hours of continued operation.
Condensation heat transfer and pressure drop of R-410A in flat aluminum multi-port tubes
NASA Astrophysics Data System (ADS)
Kim, Nae-Hyun
2018-02-01
Brazed heat exchangers with aluminum flat multi-port tubes are being used as condensers of residential air-conditioners. In this study, R-410A condensation tests were conducted in four multi-port tubes having a range of hydraulic diameter (0.78 ≤ Dh ≤ 0.95 mm). The test range covered the mass flux from 100 to 400 kg/m2 s and the heat flux at 3 kW/m2, which are typical operating conditions of residential air conditioners. Results showed that both the heat transfer coefficient and the pressure drop increased as the hydraulic diameter decreased. The effect of hydraulic diameter on condensation heat transfer was much larger than the predictions of existing correlations for the range of investigation. Comparison of the data with the correlations showed that some macro-channel tube correlations and mini-channel tube correlations reasonably predicted the heat transfer coefficient. However, macro-channel correlations highly overpredicted the pressure drop data.
Gulabani, Michell; Gupta, Akhilesh; Bannerjee, Neerja Gaur; Sood, Rajesh; Dass, Prashant
2016-04-01
An 11-year-old male child, known case of down's syndrome with congenital oesophageal stricture was posted for oesophageal dilatation. Preoperative airway assessment revealed a high arched palate, receding mandible and Mallampati Score of 2. During surgery, after loss of consciousness which was described as loss of eyelash reflex and adequate jaw relaxation, direct laryngoscopy and endotracheal intubation was attempted with a cuffed endotracheal tube number 5.0mm ID (internal diameter). The endotracheal tube could not be negotiated smoothly, so 5.0mm ID uncuffed endotracheal tube was used which passed through easily, but on auscultation revealed a significant leak. Later, intubation via a Micro Laryngeal Surgery (MLS) cuffed tube 4.0mm ID was attempted. The MLS tube advanced smoothly and there was no associated leak on positive pressure ventilation. Thus by innovative thinking and avant-garde reasoning, a definitive airway device could be positioned with no other suitable alternative at hand.
Underwater noise from geotechnical drilling and standard penetration testing.
Erbe, Christine; McPherson, Craig
2017-09-01
Geotechnical site investigations prior to marine construction typically involve shallow, small-core drilling and standard penetration testing (SPT), during which a small tube is hammered into the ground at the bottom of the borehole. Drilling (120 kW, 83 mm diameter drillbit, 1500 rpm, 16-17 m drill depth in sand and mudstone) and SPT (50 mm diameter test tube, 15 mm wall thickness, 100 kg hammer, 1 m drop height) by a jack-up rig in 7-13 m of water were recorded with a drifting hydrophone at 10-50 m range. Source levels were 142-145 dB re 1 μPa rms @ 1 m (30-2000 Hz) for drilling and 151-160 dB re 1 μPa 2 s @ 1 m (20-24 000 Hz) for SPT.
The Valsalva manoeuvre versus tourniquet for venipuncture.
Villa, Gianluca; Chelazzi, Cosimo; Giua, Rosa; Lavacchini, Laura; Tofani, Lorenzo; Zagli, Giovanni; Barbani, Francesco; De Gaudio, A Raffaele; Romagnoli, Stefano; Pinelli, Fulvio
2018-03-01
During ultrasound-guided cannulation, venous filling is required for venipuncture. Tourniquet with an elastic tube at the axilla is the most common method to induce venous stasis for cannulation of the deep veins of the arm. Although effective, this method might be associated with short- and long-term complications. Valsalva manoeuvre has been used to produce venous filling in other extrathoracic veins. The aim of this observational study is to demonstrate the effect of Valsalva manoeuvre in respect of the elastic tourniquet on venous distention during echography-guided cannulation of the deep veins of the arm. Sixty-nine patients scheduled for cannulation of basilic or brachial vein were prospectively observed. Vein diameters were recorded at rest and after 10 s of Valsalva or tourniquet placement. The mean difference between basilic vein diameters during tourniquet and Valsalva manoeuvre was 0.006 mm (95% confidence interval = -inf, 0.09) with a standard deviation of 0.5 mm (95% confidence interval = 0.5, 0.7; p > 0.01). The mean difference between brachial vein diameters during tourniquet and Valsalva manoeuvre was 0.04 mm (95% confidence interval = -0.23, 0.15) with a standard deviation of 0.8 mm (95% confidence interval = 0.7, 0.9; p > 0.01). This increase in cross-sectional basilic and brachial vein diameters was not different to that obtained with the elastic tube tourniquet.
Issues on Fabrication and Evaluation of SiC/SiC Tubes With Various Fiber Architectures
NASA Technical Reports Server (NTRS)
Yun, H. M.; DiCarlo, J. A.; Fox, D. S.
2004-01-01
SiC/SiC engine components, high-modulus Sylramic-iBN SiC fiber tows were used to form nine different tubular architectural preforms with 13 mm (0.5 in.) inner diameter and lengths of approx. 75 and 230 mm (approx. 3 and approx, 9 in.). The thin-walled preforms were then coated with a BN interphase and densified with a hybrid SiC matrix using nearly the same process steps previously established for slurry-cast melt-infiltrated Sylramic-iBN/BN/SiC flat panels. The as-fabricated CMC tubes were microstructurally evaluated and tested for tensile hoop and flexural behavior, and some of the tubes were also tested in a low-pressure burner rig test with a high thru-thickness thermal gradient. To date, four general tube scale-up issues have been identified: greater CVI deposits on outer wall than inner wall; increased ply thickness and reduced fiber fraction; poor test standards for accurately determining the hoop strength of a small-diameter tube; and poor hoop strength for architectures with seams or ply ends. The underlying mechanisms and possible methods for their minimization are discussed.
Condensation of Refrigerants on Small Tube Bundles
1988-12-01
first comprehensive condensation model was developed by Nusselt in 1916 [Ref. 4] based on the assumption that a quiescent vapor at saturation...vapor is condensed by an auxiliary condenser . The auxiliary condenser is composed of five helically wound copper tubes of 9.53 mm diameter suspended...copper tubing located in the top center of the condenser chamber. The vapor is condensed in the storage cylinder by means of a helical copper coil
The local heat transfer mathematical model between vibrated fluidized beds and horizontal tubes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Xuejun; College of Biology and Chemical Engineering, Panzhihua University, Panzhihua 617000; Ye, Shichao
2008-05-15
A dimensionless mathematical model is proposed to predict the local heat transfer coefficients between vibrated fluidized beds and immersed horizontal tubes, and the effects of the thickness of gas film and the contact time of particle packets are well considered. Experiments using the glass beads (the average diameter bar d{sub p}=1.83mm) were conducted in a two-dimensional vibrated fluidized bed (240 mm x 80 mm). The local heat transfer law between vibrated fluidized bed and horizontal tube surface has been investigated. The results show that the values of theoretical prediction are in good agreement with experimental data, so the model ismore » able to predict the local heat transfer coefficients between vibrated fluidized beds and immersed horizontal tubes reasonably well, and the error is in range of {+-}15%. The results can provide references for future designing and researching on the vibrated fluidized beds with immersed horizontal tubes. (author)« less
Diameter Effect Curve and Detonation Front Curvature Measurements for ANFO
NASA Astrophysics Data System (ADS)
Catanach, R. A.; Hill, L. G.
2001-06-01
Diameter effect and front curvature measurements are reported for rate stick experiments on commercially available prilled ANFO (ammonium nitrate-fuel oil) at ambient temperature. The shots were fired in paper tubes so as to provide minimal confinement. Diameters ranged from 77 mm. (≈ failure diameter) to 200 mm., with the tube length being ten diameters in all cases. Each detonation wave shape was fit with an analytic form, from which the local normal velocity Dn and total curvature κ were generated as a function of radius R, then plotted parametrically to generate a D_n(κ) function. The resulting behavior deviates substantially from that of previous explosives,(Hill,L.G., Bdzil,J.B., and Aslam,T.D., 11^th) Detonation Symposium, 1998^,(Hill,L.G., Bdzil,J.B., Davis,W.C., and Engelke,R., Shock Compression of Condensed Matter, 1999) in which curves for different stick sizes overlay well for small κ but diverge for large κ, and for which κ increases monotonically with R to achieve a maximum value at the charge edge. For ANFO, we find that κ achieves a maximum at an intermediate R and that D_n(κ) curves for different stick sizes are widely separated with no overlap whatsoever.
Experimental Studies on Grooved Double Pipe Heat Exchanger with Different Groove Space
NASA Astrophysics Data System (ADS)
Sunu, P. W.; Arsawan, I. M.; Anakottapary, D. S.; Santosa, I. D. M. C.; Yasa, I. K. A.
2018-01-01
Experimental studies were performed on grooved double pipe heat exchanger (DPHE) with different groove space. The objective of this work is to determine optimal heat transfer parameter especially logarithmic mean temperature difference (LMTD). The document in this paper also provides the total heat observed by the cold fluid. The rectangular grooves were incised on outer surface of tube side with circumferential pattern and two different grooves space, namely 1 mm and 2 mm. The distance between grooves and the grooves high were kept constant, 8 mm and 0.3 mm respectively. The tube diameter is 20 mm and its made of aluminium. The shell is made of acrylic which has 28 mm in diameter. Water is used as the working fluid. Using counter flow scheme, the cold fluid flows in the annulus room of DPHE. The volume flowrate of hot fluid remains constant at 15 lpm. The volume flowrate of cold fluid were varied from 11 lpm to 15 lpm. Based on logarithmic mean temperature difference analysis, the LMTD of 1 mm grooves space was higher compared to that of 2 mm grooves space. The smaller grooves space has more advantage since the recirculating region are increased which essentially cause larger heat transfer enhancement.
NASA Astrophysics Data System (ADS)
Devade, Kiran D.; Pise, Ashok T.
2017-01-01
Ranque Hilsch vortex tube is a device that can produce cold and hot air streams simultaneously from pressurized air. Performance of vortex tube is influenced by a number of geometrical and operational parameters. In this study parametric analysis of vortex tube is carried out. Air is used as the working fluid and geometrical parameters like length to diameter ratio (15, 16, 17, 18), exit valve angles (30°-90°), orifice diameters (5, 6 and 7 mm), 2 entry nozzles and tube divergence angle 4° is used for experimentation. Operational parameters like pressure (200-600 kPa), cold mass fraction (0-1) is varied and effect of Mach number at the inlet of the tube is investigated. The vortex tube is tested at sub sonic (0 < Ma < 1), sonic (Ma = 1) and supersonic (1 < Ma < 2) Mach number, and its effect on thermal performance is analysed. As a result it is observed that, higher COP and low cold end temperature is obtained at subsonic Ma. As CMF increases, COP rises and cold and temperature drops. Optimum performance of the tube is observed for CMF up to 0.5. Experimental correlations are proposed for optimum COP. Parametric correlation is developed for geometrical and operational parameters.
Pulsating Heat pipe Only for Space (PHOS): results of the REXUS 18 sounding rocket campaign
NASA Astrophysics Data System (ADS)
Creatini, F.; Guidi, G. M.; Belfi, F.; Cicero, G.; Fioriti, D.; Di Prizio, D.; Piacquadio, S.; Becatti, G.; Orlandini, G.; Frigerio, A.; Fontanesi, S.; Nannipieri, P.; Rognini, M.; Morganti, N.; Filippeschi, S.; Di Marco, P.; Fanucci, L.; Baronti, F.; Mameli, M.; Manzoni, M.; Marengo, M.
2015-11-01
Two Closed Loop Pulsating Heat Pipes (CLPHPs) are tested on board REXUS 18 sounding rocket in order to obtain data over a relatively long microgravity period (approximately 90 s). The CLPHPs are partially filled with FC-72 and have, respectively, an inner tube diameter larger (3 mm) and slightly smaller (1.6 mm) than the critical diameter evaluated in static Earth gravity conditions. On ground, the small diameter CLPHP effectively works as a Pulsating Heat Pipe (PHP): the characteristic slug and plug flow pattern forms inside the tube and the heat exchange is triggered by thermally driven self-sustained oscillations of the working fluid. On the other hand, the large diameter CLPHP works as a two- phase thermosyphon in vertical position and doesn't work in horizontal position: in this particular condition, the working fluid stratifies within the device as the surface tension force is no longer able to balance buoyancy. Then, the idea to test the CLPHPs in reduced gravity conditions: as the gravity reduces the buoyancy forces becomes less intense and it is possible to recreate the typical PHP flow pattern also for larger inner tube diameters. This allows to increase the heat transfer rate and, consequently, to decrease the overall thermal resistance. Even though it was not possible to experience low gravity conditions due to a failure in the yoyo de-spin system, the thermal response to the peculiar acceleration field (hyper-gravity) experienced on board are thoroughly described.
A study of the rheological properties of endodontic sealers.
Lacey, S; Pitt Ford, T R; Watson, T F; Sherriff, M
2005-08-01
To test the hypothesis that there would be no statistically significant difference in viscosity-related measures of endodontic sealers or change in these with strain rate, internal diameter or powder : liquid ratio in a capillary system. Materials used were Apexit, Tubliseal EWT, Grossman's sealer and Ketac-endo. Viscosity-related measures were tested in a two-plate test, and in a capillary rheometer. The mean values (n = 12) for thickness and diameter of material formed between two glass plates were tested with one-way analysis of variance. Pressure was applied to a capillary rheometer at strain rates 5 and 10 mm min(-1) in tubes of internal diameter 0.6 and 1.2 mm. Tubliseal EWT had a thinner film thickness than the other sealers (alpha = 0.05). The difference in diameter between Tubliseal EWT and the other sealers was significant apart from Apexit. Increased strain rate gave a significant increase (alpha = 0.05) in the flow of all sealers. Narrower tubes produced increased velocity, which was significant for all sealers, and reduced volumetric flow, which was significant for all sealers except Grossman's 2 : 1 (Wilcoxon signed rank test). Reduction in powder : liquid ratio of Grossman's significantly increased flow in narrow tubes and at higher strain rate (Mann-Whitney test). There was a significant difference between the flow of Tubliseal EWT and the other sealers tested in the two-plate test; capillary flow was affected by sealer, internal diameter, strain rate and powder : liquid ratio. The null hypotheses were rejected.
Finite element modelling of AA6063T52 thin-walled tubes under quasi-static axial loading
NASA Astrophysics Data System (ADS)
Othman, A.; Ismail, AE
2018-04-01
The behavior of aluminum alloy 6063T52 thin walled tubes have been present in this paper to determine absorbed energy under quasi-static axial loading. The correlation and comparison have been implemented for each experimental and finite element analysis results, respectively. Wall-thickness of 1.6 and 1.9 mm were selected and all specimen tested under room temperature standard. The length of each specimen were fixed at 125 mm as well as diameter as well as a width and diameter of the tube at 50.8 mm. The two types of tubular cross-section were examined whereas a round and square thin-walled profiles. The specific absorbed energy (SEA) and crush force efficiency (CFE) were analyzed for each specimen and model to see the behavior induced to failure under progressive collapse. Result showed that a correlation less than 5% different between both of comparison experimental and finite element model. It has been found that the thin walled round tube absorbed more energy rather than square profile in term of specific energy with both of either 1.6 or 1.9 of 23.93% and 35.36%, respectively. Overall for crush force efficiency (CFE) of each tube profile around 0.42 to 0.58 value. Indicated that the all specimen profile fail under progressive damage. The calibration between deformed model and experimental specimen were examined and discussed. It was found that the similarity failure mechanism observed for each thin walled profiles.
PHOS Experiment: Thermal Response of a Large Diameter Pulsating Heat Pipe on Board REXUS-18 Rocket
NASA Astrophysics Data System (ADS)
Creatini, F.; Guidi, G. M.; Belfi, F.; Cicero, G.; Fioriti, D.; Di Prizio, D.; Piacquadio, S.; Becatti, G.; Orlandini, G.; Frigerio, A.; Fontanesi, S.; Nannipieri, P.; Rognini, M.; Morganti, N.; Filippeschi, S.; Di Marco, P.; Fanucci, L.; Baronti, F.; Mameli, M.; Marengo, M.; Manzoni, M.
2015-09-01
In the present work, the results of two Closed Loop Pulsating Heat Pipes (CLPHPs) tested on board REXUS-1 8 sounding rocket in order to get experimental data over a relatively broad reduced gravity period (about 90 s) are thoroughly discussed. The CLPHPs are partially filled with refrigerant FC-72 and have, respectively, an inner tube diameter larger (3 .0 mm) and slightly smaller (1 .6 mm) than a critical diameter defined on Earth gravity conditions. On ground, the small diameter CLPHP works as a real Pulsating Heat Pipe (PHP): the typical capillary slug flow pattern forms inside the device and the heat exchange is triggered by self-sustained thermally driven oscillations of the working fluid. Conversely, the large diameter CLPHP behaves like a two-phase thermosyphon in vertical position while does not operate in horizontal position as the working fluid stratifies within the tube and surface tension is not able to balance buoyancy. Then, the idea to test the CLPHPs under reduced gravity conditions: as soon as gravity reduces, buoyancy becomes less intense and the typical capillary slug flow pattern can also forms within a tube with a larger diameter. Moreover, this allows to increase the heat transfer rate and, consequently, to decrease the overall thermal resistance. Even though it was not possible to experience the expected reduced gravity conditions due to a failure of the yo-yo de-spin system, the thermal response to the peculiar acceleration field (hyper-gravity) experienced on board are thoroughly described.
NASA Astrophysics Data System (ADS)
Spindler, Klaus; Müller-Steinhagen, Hans
2009-05-01
An experimental investigation of flow boiling heat transfer in a commercially available microfin tube with 9.52 mm outer diameter has been carried out. The microfin tube is made of copper with a total fin number of 55 and a helix angle of 15°. The fin height is 0.24 mm and the inner tube diameter at fin root is 8.95 mm. The test tube is 1 m long and is electrically heated. The experiments have been performed at saturation temperatures between 0 and -20°C. The mass flux was varied between 25 and 150 kg/m2s, the heat flux from 15,000 W/m2 down to 1,000 W/m2. All measurements have been performed at constant inlet vapour quality ranging from 0.1 to 0.7. The measured heat transfer coefficients range from 1,300 to 15,700 W/m2K for R134a and from 912 to 11,451 W/m2K for R404A. The mean heat transfer coefficient of R134a is in average 1.5 times higher than for R404A. The mean heat transfer coefficient has been compared with the correlations by Koyama et al. and by Kandlikar. The deviations are within ±30% and ±15%, respectively. The influence of the mass flux on the heat transfer is most significant between 25 and 62.5 kg/m2s, where the flow pattern changes from stratified wavy flow to almost annular flow. This flow pattern transition is shifted to lower mass fluxes for the microfin tube compared to the smooth tube.
NASA Astrophysics Data System (ADS)
Nigodjuk, V. E.; Sulinov, A. V.
2018-01-01
The article presents the results of an experimental study of the hydraulic characteristics of capillary elements of the injector head of jet engines in isothermal fluid flow and the proposed method of their calculation. The main geometric dimensions of the capillaries in the experiment were changed in the following range: Inner diameter from 0.16 to 0.36 mm, length from 4.3 to 158 mm and relative length from 25 to 614 and the inlet edge of the capillaries: sharp or smooth the leading edge. As the working fluid during the tests were distilled water, acetone and ethyl alcohol. Based on the results of a study of the dependences for calculation of ultimate losses in laminar and turbulent flow regimes in capillary tubes with smooth and sharp edges input. The influence of surface tension forces on loss of input on a sharp cutting edge. Experimentally confirmed the possibility of calculating the linear coefficient of hydraulic resistance of capillary tubes with a diameter of 0.16-0.36 mm in isothermal stable during the known dependencies that are valid for hydrodynamically smooth round tube.
NASA Technical Reports Server (NTRS)
Weislogel, Mark M.
1996-01-01
A steady capillary driven flow is developed for a liquid index in a circular tube which is partially coated with a surface modifier to produce a discontinuous wetting condition from one side of the tube to the other. The bulk flow is novel in that it is truly steady, and controlled solely by the physics associated with dynamic wetting. The influence of gravity on the flow is minimized through the use of small diameter tubes approximately O(1 mm) tested horizontally in a laboratory and larger tubes approximately O(10 mm) tested in the low gravity environment of a drop tower. Average steady velocities are predicted and compared against a large experimental data set which includes the effects of tube dimensions and fluid properties. The sensitivity of the velocity to surface cleanliness is dramatic and the advantages of experimentation in a microgravity environment are discussed.
Rodríguez, C; Anel, L; Alvarez, M; Anel, E; Boixo, J C; Chamorro, C A; de Paz, P
2006-04-01
In vivo ovum pick-up (OPU) in sheep may be improved with a proper choice of aspiration elements (needle and tubing) and aspiration vacuum pressure. In the present study, two experiments were carried out. In Expt 1, visible follicles in ovaries of slaughtered ewes (treated separately according to their diameters: small<3 mm, medium 3-5 mm and large>5 mm) were aspirated using different combinations of the three studied factors such as aspiration flow rate (10, 20, 30, 40 and 50 ml water/min), needle gauge (18 and 20 G) and tubing inner diameter (1, 2 or 3 mm internal diameter). In Expt 2, a study with two 18 G needles of different lengths (18 G: 82 mm; 18 GL: 600 mm) was carried out, using ovaries obtained post-mortem, and performing in vivo laparoscopic follicular aspiration on ewes. We considered good quality oocytes as those with both complete compact cumulus and a homogeneous cytoplasm. Recovery rate, proportion of good quality oocytes (good quality oocytes/100 oocytes recovered) and overall efficiency (good quality oocytes/100 follicles aspirated) were noted. In Expt 1, aspiration flow rate affect remarkable proportion of good quality oocytes (69.5%, 50.5%, 44.8%, 36.5% and 28.3% for flows from 10 to 50 ml/min respectively, p<0.05). Needle gauge did not affect aspiration device efficiency. Thin and intermediate tubings were more effective (overall efficiency rates: 34.9%, 32.3% and 28.1% for 1, 2 and 3 mm respectively, p<0.05). Follicle size did not affect recovery rate, but proportion of good quality oocytes was higher for large (77.9%) and medium (64.4%) follicles (p<0.05). Finally, some combinations of the aspiration device showed greater effectiveness. In Expt 2, needle length did not influence recovery rate, but good quality oocytes rate was significantly modified both post-mortem and in vivo (good quality rate for 18 G vs 18 GL needles: 69.5% vs 47.7% and 58.1% vs 25.4%, post-mortem and in vivo respectively, p<0.05). We conclude that low-aspiration flow rates (10 and 20 ml/min) with thin or intermediate tubings (1 and 2 mm), and any short needle (18 G or 20 G) are the most adequate aspiration factors for OPU in sheep.
Thermal performance comparison of oscillating heat pipes with and without helical micro-grooves
NASA Astrophysics Data System (ADS)
Qu, Jian; Li, Xiaojun; Xu, Qian; Wang, Qian
2017-11-01
This paper presents an experimental investigation to compare the thermal performance of three closed loop oscillating heat pipes (OHPs) with and without internal helical microgrooves at vertical and horizontal orientations. All of these OHPs were made from copper tubes and have three turns with lengths of 70, 230 and 110 mm at the evaporator, adiabatic and condenser sections, respectively. Deionized water was used as the working fluid at a volumetric filling ratio of 50%. The internal diameters (IDs) of two smooth-tube OHPs are 4.0 and 4.8 mm, respectively, and the internal diameter of micro-grooved OHP without groove structures is about 4.5 mm. Experimental results demonstrated that the addition of groove structures make the OHP remarkably outperform smooth-tube OHPs in both effective thermal conductivity and thermal resistance. The thermal resistance of vertically-oriented micro-grooved OHP could be lowered to 0.057 °C/W associated with an effective thermal conductivity of 6.1 × 104 W/ (m·K) at the input heat flux of 3.8 × 104 W/m2. Compared to smooth-tube OHPs, preliminary mechanism analysis reveals that local heat transfer coefficients both at the heating and cooling sections of micro-grooved OHP could be significantly improved. Moreover, enhanced liquid backflow to the evaporator due to microgroove-induced capillarity is also responsible for the OHP performance enhancement.
Experimental study of cryogen spray properties for application in dermatologic laser surgery.
Aguilar, Guillermo; Majaron, Boris; Karapetian, Emil; Lavernia, Enrique J; Nelson, J Stuart
2003-07-01
Cryogenic sprays are used for cooling human skin during laser dermatologic surgery. In this paper, six straight-tube nozzles are characterized by photographs of cryogenic spray shapes, as well as measurements of average droplet diameter, velocity, and temperature. A single-droplet evaporation model to predict average spray droplet diameter and temperature is tested using the experimental data presented here. The results show two distinct spray patterns--sprays for 1.4-mm-diameter nozzles (wide nozzles) show significantly larger average droplet diameters and higher temperatures as a function of distance from the nozzle compared with those for 0.5-0.8-mm-diameter nozzles (narrow nozzles). These results complement and support previously reported studies, indicating that wide nozzles induce more efficient heat extraction than the narrow nozzles.
Soft Plumbing: Direct-Writing and Controllable Perfusion of Tubular Soft Materials
NASA Astrophysics Data System (ADS)
Guenther, Axel; Omoruwa, Patricia; Chen, Haotian; McAllister, Arianna; Jeronimo, Mark; Malladi, Shashi; Hakimi, Navid; Cao, Li; Ramchandran, Arun
2016-11-01
Tubular and ductular structures are abundant in tissues in a wide variety of diameters, wall thicknesses, and compositions. In spite of their relevance to engineered tissues, organs-on-chips and soft robotics, the rapid and consistent preparation of tubular structures remains a challenge. Here, we use a microfabricated printhead to direct-write biopolymeric tubes with dimensional and compositional control. A biopolymer solution is introduced to the center layer of the printhead, and the confining fluids to the top and the bottom layers. The radially flowing biopolymer solution is sandwiched between confining solutions that initiate gelation, initially assuming the shape of a funnel until emerging through a cylindrical confinement as a continuous biopolymer tube. Tubular constructs of sodium alginate and collagen I were obtained with inner diameters (0.6-2.2mm) and wall thicknesses (0.1-0.4mm) in favorable agreement with predictions of analytical models. We obtained homogeneous tubes with smooth and buckled walls and heterotypic constructs that possessed compositions that vary along the tube circumference or radius. Ductular soft materials were reversibly hosted in 3D printed fluidic devices for the perfusion at well-defined transmural pressures to explore the rich variety of dynamical features associated with collapsible tubes that include buckling, complete collapse, and self-oscillation.
NASA Astrophysics Data System (ADS)
Klochko, Andrei V.; Starikovskaia, Svetlana M.; Xiong, Zhongmin; Kushner, Mark J.
2014-09-01
Nanosecond electrical discharges in the form of ionization waves are of interest for rapidly ionizing and exciting complex gas mixtures to initiate chemical reactions. Operating with a small discharge tube diameter can significantly increase the specific energy deposition and so enable optimization of the initiation process. Analysis of the uniformity of energy release in small diameter capillary tubes will aid in this optimization. In this paper, results for the experimentally derived characteristics of nanosecond capillary discharges in air at moderate pressure are presented and compared with results from a two-dimensional model. The quartz capillary tube, having inner and outer diameters of 1.5 and 3.4 mm, is about 80 mm long and filled with synthetic dry air at 27 mbar. The capillary tube with two electrodes at the ends is inserted into a break of the central wire of a long coaxial cable. A metal screen around the tube is connected to the cable ground shield. The discharge is driven by a 19 kV 35 ns voltage pulse applied to the powered electrode. The experimental measurements are conducted primarily by using a calibrated capacitive probe and back current shunts. The numerical modelling focuses on the fast ionization wave (FIW) and the plasma properties in the immediate afterglow after the conductive plasma channel has been established between the two electrodes. The FIW produces a highly focused region of electric field on the tube axis that sustains the ionization wave that eventually bridges the electrode gap. Results from the model predict FIW propagation speed and current rise time that agree with the experiment.
30 CFR 18.65 - Flame test of hose.
Code of Federal Regulations, 2013 CFR
2013-07-01
... MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Inspections and Tests § 18.65 Flame... wire gauze. (2) A Pittsburgh-Universal Bunsen-type burner (inside diameter of burner tube 11 mm.), or...
30 CFR 18.65 - Flame test of hose.
Code of Federal Regulations, 2011 CFR
2011-07-01
... MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Inspections and Tests § 18.65 Flame... wire gauze. (2) A Pittsburgh-Universal Bunsen-type burner (inside diameter of burner tube 11 mm.), or...
30 CFR 18.65 - Flame test of hose.
Code of Federal Regulations, 2014 CFR
2014-07-01
... MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Inspections and Tests § 18.65 Flame... wire gauze. (2) A Pittsburgh-Universal Bunsen-type burner (inside diameter of burner tube 11 mm.), or...
30 CFR 18.65 - Flame test of hose.
Code of Federal Regulations, 2012 CFR
2012-07-01
... MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Inspections and Tests § 18.65 Flame... wire gauze. (2) A Pittsburgh-Universal Bunsen-type burner (inside diameter of burner tube 11 mm.), or...
Three-degree-of-freedom ultrasonic motor using a 5-mm-diameter piezoelectric ceramic tube.
Mingsen Guo; Junhui Hu; Hua Zhu; Chunsheng Zhao; Shuxiang Dong
2013-07-01
A small three-degree-of-freedom ultrasonic motor has been developed using a simple piezoelectric lead zirconate titanate (PZT)-tube stator (OD 5 mm, ID 3 mm, length 15 mm). The stator drives a ball-rotor into rotational motion around one of three orthogonal (x-, y-, and z-) axes by combing the first longitudinal and second bending vibration modes. A motor prototype was fabricated and characterized; its performance was superior to those of previous motors made with a PZT ceramic/metal composite stator of comparable size. The method for further improving the performance was discussed. The motor can be further miniaturized and it has potential to be applied to medical microrobots, endoscopes or micro laparoscopic devices, and cell manipulation devices.
NASA Astrophysics Data System (ADS)
Bauman, M. A.; Gillies, G. T.; Raghavan, R.; Brady, M. L.; Pedain, C.
2004-01-01
An agarose gelatin having nanoscale transport properties similar to those of in vivo mammalian brain was employed as a surrogate for living brain tissue in the evaluation of infusion therapy protocols and neurocatheters to be used in the treatment of brain tumours. The catheters under study were a polyimide tube of 950 µm outer diameter (OD) and 750 µm inner diameter (ID), and a silicone tube of 2.5 mm OD and 1.25 mm ID. From the pressure profiles that were measured during infusions of a solution of Bromphenol Blue dye into this gel, we infer that forces on the order of 0.1 fN were driving the solute molecules through the {\\approx } 200 nm intramatrix voids in the gel at rates of {\\approx } 10\
Use of multi-coil parallel-gap resonators for co-registration EPR/NMR imaging
NASA Astrophysics Data System (ADS)
Kawada, Yuuki; Hirata, Hiroshi; Fujii, Hirodata
2007-01-01
This article reports experimental investigations on the use of RF resonators for continuous-wave electron paramagnetic resonance (cw-EPR) and proton nuclear magnetic resonance (NMR) imaging. We developed a composite resonator system with multi-coil parallel-gap resonators for co-registration EPR/NMR imaging. The resonance frequencies of each resonator were 21.8 MHz for NMR and 670 MHz for EPR. A smaller resonator (22 mm in diameter) for use in EPR was placed coaxially in a larger resonator (40 mm in diameter) for use in NMR. RF magnetic fields in the composite resonator system were visualized by measuring a homogeneous 4-hydroxy-2,2,6,6-tetramethyl-piperidinooxy (4-hydroxy-TEMPO) solution in a test tube. A phantom of five tubes containing distilled water and 4-hydroxy-TEMPO solution was also measured to demonstrate the potential usefulness of this composite resonator system in biomedical science. An image of unpaired electrons was obtained for 4-hydroxy-TEMPO in three tubes, and was successfully mapped on the proton image for five tubes. Technical problems in the implementation of a composite resonator system are discussed with regard to co-registration EPR/NMR imaging for animal experiments.
Cryogenic thermal emittance measurements on small-diameter stainless steel tubing
NASA Astrophysics Data System (ADS)
Jahromi, Amir E.; Tuttle, James G.; Canavan, Edgar R.
2017-12-01
The Mid Infrared Instrument aboard the James Webb Space Telescope includes a mechanical cryocooler which cools its detectors to their 6 K operating temperature. The refrigerant flows through several meters of ~2 mm diameter 304L stainless steel tubing, with some sections gold plated, and some not, which are exposed to their environment. An issue of water freezing onto the tube surfaces is mitigated by running a warm gas through the lines to sublimate the frozen water. To model the effect of this process on nearby instruments, an accurate measure of the tube emittance is needed. Previously we reported the absorptance of the gold plated stainless steel tubing as a function of source temperature (i.e. its environment). In this work the thermal emittance of the uncoated tubing is measured as a function of its temperature between 100 and 280 K. These values lead to an accurate prediction of the minimum length of time required to thermally recycle the system. We report the technique and present the results.
Cryogenic Thermal Emittance Measurements on Small-Diameter Stainless Steel Tubing
NASA Technical Reports Server (NTRS)
Jahromi, Amir E.; Tuttle, James G.; Canavan, Edgar R.
2017-01-01
The Mid Infrared Instrument aboard the James Webb Space Telescope includes a mechanical cryocooler which cools its detectors to their 6 K operating temperature. The refrigerant flows through several meters of 2 mm diameter 304L stainless steel tubing, with some sections gold plated, and some not, which are exposed to their environment. An issue of water freezing onto the tube surfaces is mitigated by running a warm gas through the lines to sublimate the frozen water. To model the effect of this process on nearby instruments, an accurate measure of the tube emittance is needed. Previously we reported the absorptance of the gold plated stainless steel tubing as a function of source temperature (i.e. its environment). In this work the thermal emittance of the uncoated tubing is measured as a function of its temperature between 100 and 280 K. These values lead to an accurate prediction of the minimum length of time required to thermally recycle the system. We report the technique and present the results.
Cryogenic Thermal Emittance Measurements on Small-Diameter Stainless Steel Tubing
NASA Technical Reports Server (NTRS)
Jahromi, A. E.; Tuttle, J. G.; Canavan, E. R.
2017-01-01
The Mid Infrared Instrument aboard the James Webb Space Telescoep includes a mechanical cryocooler which cools its detectors to their 6 K operating temperature. The refrigerant flows through several meters of approximately 2 mm diameter 304L stainless steel tubing, with some sections gold plated, and some not, which are exposed to their environment. An issue of water freezing onto the tube surfaces is mitigated by a running a warm gas through the lines to sublimate the water. To model the effect of this process on nearby instruments, an accurate measure of the tube emittance is needed. Previously we reported the abosprtance of the gold plated stainless steel tubing as a function of source temperature (i.e. its environment). In this work the thermal emittance of the uncoated tubing is measured as a function of its temperature between 100 and 300 K. This value leads to an accurate prediction of the minimum length of time required to thermally recycle the system. We report the technique and present the results.
Synthetic Aperture Acoustic Imaging for Roadside Detection of Solid Objects
2014-11-20
automobile, rail, and air traffic, and wind background noise. 4.1.1 Targets Six braided nylon cords with diameters 3.2, 4.8, 6.4, 9.5 12.9 and 15.9mm (1/8, 3...fibers, (center) six braided nylon cords of increasing diameter (left) folded aluminum retroreflector. 0 ·5 ·5 ·10 ·10 ·15 $ 53’ ., ·15 ’-’ :s...impedance tube, here show in a vertical orientation has a speaker hosed at the top, two microphones flush mounted the the inner wall of the tube, and a
NASA Astrophysics Data System (ADS)
Imhan, Khalil Ibraheem; Baharudin, B. T. H. T.; Zakaria, Azmi; Ismail, Mohd Idris Shah B.; Alsabti, Naseer Mahdi Hadi; Ahmad, Ahmad Kamal
2018-02-01
Laser forming is a flexible control process that has a wide spectrum of applications; particularly, laser tube bending. It offers the perfect solution for many industrial fields, such as aerospace, engines, heat exchangers, and air conditioners. A high power pulsed Nd-YAG laser with a maximum average power of 300 W emitting at 1064 nm and fiber-coupled is used to irradiate stainless steel 304 (SS304) tubes of 12.7 mm diameter, 0.6 mm thickness and 70 mm length. Moreover, a motorized rotation stage with a computer controller is employed to hold and rotate the tube. In this paper, an experimental investigation is carried out to improve the laser tube bending process by enhancing the absorption coefficient of the material and the mechanical formability using laser softening heat treatment. The material surface is coated with an oxidization layer; hence, the material absorption of laser light is increased and the temperature rapidly rises. The processing speed is enhanced and the output bending angle is increased to 1.9° with an increment of 70% after the laser softening heat treatment.
Microendoscopy of the eustachian tube and the middle ear
NASA Astrophysics Data System (ADS)
Hopf, Juergen U. G.; Linnarz, Marietta; Gundlach, Peter; Scherer, Hans H.; Lutze-Koffroth, C.; Loerke, S.; Voege, Karl H.; Tschepe, Johannes; Mueller, Gerhard J.
1992-08-01
Progressive miniaturization of flexible fiberoptic instruments has made it possible to perform atraumatic endoscopy of the Eustachian tube and tympanic cavity with an intact ear drum. By means of a special set of carrier- and balloon-catheters which are partly actively steerable, flexible microendoscopes with outside diameters of 290 - 700 micrometers are inserted through the nasal cavity into the nasopharyngeal opening of the Eustachian tube and carefully advanced into the middle ear compartment under permanent direct visual control. Second generation microendoscopes with outside diameters of 750 to 1000 micrometers are equipped with a one- direction tip-steering mechanism which allows deflection up to 90 degrees. In addition to it, the use of two special types of four-function scopes (outside diameter: 1.6 mm and 1.8 mm) fitted with a one-lumen working channel are presented. This new technique of `Transnasal Tubo-Tympanoscopy' (TTT) only needs local anesthesia, normally is performed on an outpatient basis, and is indicated for the diagnosis of any disturbances of the sound conducting apparatus (ear drum and ossicular chain) like chronic otitis media and oto-sclerosis and of those sensorineural hearing disorders on which -- until today -- only the traditional surgical tympanoscopy could provide morphological information on the pathogenesis of the hearing loss, e.g., on assumed round window ruptures. By this minimal invasive and minimal traumatizing method pathological alterations of the ossicular chain as well as obstructions in the cartilaginous and the osseous part of the Eustachian tube can be directly visualized.
Positron autoradiography for intravascular imaging: feasibility evaluation
NASA Astrophysics Data System (ADS)
Shikhaliev, Polad M.; Xu, Tong; Ducote, Justin L.; Easwaramoorthy, Balasubramaniam; Mukherjee, Jogeshwar; Molloi, Sabee
2006-02-01
Approximately 70% of acute coronary artery disease is caused by unstable (vulnerable) plaques with an inflammation of the overlying cap and high lipid content. A rupturing of the inflamed cap of the plaque results in propagation of the thrombus into the lumen, blockage of the artery and acute ischaemic syndrome or sudden death. Morphological imaging such as angiography or intravascular ultrasound cannot determine inflammation status of the plaque. A radiotracer such as 18F-FDG is accumulated in vulnerable plaques due to higher metabolic activity of the inflamed cap and could be used to detect a vulnerable plaque. However, positron emission tomography (PET) cannot detect the FDG-labelled plaques because of respiratory and heart motions, small size and low activity of the plaques. Plaques can be detected using a miniature particle (positron) detector inserted into the artery. In this work, a new detector concept is investigated for intravascular imaging of the plaques. The detector consists of a storage phosphor tip bound to the end of an intravascular catheter. It can be inserted into an artery, absorb the 18F-FDG positrons from the plaques, withdrawn from the artery and read out. Length and diameter of the storage phosphor tip can be matched to the length and the diameter of the artery. Monte Carlo simulations and experimental evaluations of coronary plaque imaging with the proposed detector were performed. It was shown that the sensitivity of the storage phosphor detector to the positrons of 18F-FDG is sufficient to detect coronary plaques with 1 mm and 2 mm sizes and 590 Bq and 1180 Bq activities in the arteries with 2 mm and 3 mm diameters, respectively. An experimental study was performed using plastic tubes with 2 mm diameter filled with an FDG solution, which simulates blood. FDG spots simulating plaques were placed over the surface of the tube. A phosphor tip was inserted into the tube and imaged the plaques. Exposure time was 1 min in all simulations and experiments. Experiments showed that detecting the coronary plaques using the proposed technique is possible. The proposed technique has the potential for fast and accurate detection of vulnerable coronary and other intravascular plaques.
Confocal microlaparoscope for imaging the fallopian tube
NASA Astrophysics Data System (ADS)
Wu, Tzu-Yu; Rouse, Andrew R.; Chambers, Setsuko K.; Hatch, Kenneth D.; Gmitro, Arthur F.
2014-11-01
Recent evidence suggests that ovarian cancer can originate in the fallopian tube. Unlike many other cancers, poor access to the ovary and fallopian tubes has limited the ability to study the progression of this deadly disease and to diagnosis it during the early stage when it is most amenable to therapy. A rigid confocal microlaparoscope system designed to image the epithelial surface of the ovary in vivo was previously reported. A new confocal microlaparoscope with an articulating distal tip has been developed to enable in vivo access to human fallopian tubes. The new microlaparoscope is compatible with 5-mm trocars and includes a 2.2-mm-diameter articulating distal tip consisting of a bare fiber bundle and an automated dye delivery system for fluorescence confocal imaging. This small articulating device should enable the confocal microlaparoscope to image early stage ovarian cancer arising inside the fallopian tube. Ex vivo images of animal tissue and human fallopian tube using the new articulating device are presented along with in vivo imaging results using the rigid confocal microlaparoscope system.
Reducing adhesion and agglomeration within a cloud of combustible particles
NASA Technical Reports Server (NTRS)
Ross, Howard D.
1988-01-01
The study of combustible particle clouds inside flame tubes is of fundamental scientific interest as well as a practical concern. Only the suspended concentration is important to the combustion process, so that assurances must be provided that a minimum of particles adheres to the tube wall. This paper demonstrates experimentally the ability to minimize adhesion and agglomeration of acoustically-mixed lycopodium particles within a 5-cm diameter lexan flame tube. The area density of particles (ADP) adhering to the wall of bare lexan tubes was measured at greater than 100 particles/sq mm. The nature of adhesion was found to be clearly electrostatic, with the ADP level aggravated by increased mixing time, vigor, and the concentration of particles. Increases in the conductivity of the air and the tube wall did not affect ADP levels substantially. However, the observed adhesion was reduced to less than 10 p/sq mm when the air was ionized by use of an alpha emitter mounted on the inner walls of the flame tube.
NASA Astrophysics Data System (ADS)
Zhang, Hui-Yong; Li, Jun-Ming; Sun, Ji-Liang; Wang, Bu-Xuan
2016-01-01
A theoretical model is developed for condensation heat transfer of binary refrigerant mixtures in mini-tubes with diameter about 1.0 mm. Condensation heat transfer of R410A and R32/R134a mixtures at different mass fluxes and saturated temperatures are analyzed, assuming that the phase flow pattern is annular flow. The results indicate that there exists a maximum interface temperature at the beginning of condensation process for azeotropic and zeotropic mixtures and the corresponding vapor quality to the maximum value increases with mass flux. The effects of mass flux, heat flux, surface tension and tube diameter are analyzed. As expected, the condensation heat transfer coefficients increase with mass flux and vapor quality, and increase faster in high vapor quality region. It is found that the effects of heat flux and surface tension are not so obvious as that of tube diameter. The characteristics of condensation heat transfer of zeotropic mixtures are consistent to those of azeotropic refrigerant mixtures. The condensation heat transfer coefficients increase with the concentration of the less volatile component in binary mixtures.
Heat transfer to small horizontal cylinders immersed in a fluidized bed
DOE Office of Scientific and Technical Information (OSTI.GOV)
Friedman, J.; Koundakjian, P.; Naylor, D.
2006-10-15
Heat transfer to horizontal cylinders immersed in fluidized beds has been extensively studied, but mainly in the context of heat transfer to boiler tubes in coal-fired beds. As a result, most correlations in the literature have been derived for cylinders of 25-50 mm diameter in vigorously fluidizing beds. In recent years, fluidized bed heat treating furnaces fired by natural gas have become increasingly popular, particularly in the steel wire manufacturing industry. These fluidized beds typically operate at relatively low fluidizing rates and with small diameter wires (1-6 mm). Nusselt number correlations developed based on boiler tube studies do not extrapolatemore » down to these small size ranges and low fluidizing rates. In order to obtain reliable Nusselt number data for these size ranges, an experimental investigation has been undertaken using two heat treating fluidized beds; one a pilot-scale industrial unit and the other a lab-scale (300 mm diameter) unit. Heat transfer measurements were obtained using resistively heated cylindrical samples ranging from 1.3 to 9.5 mm in diameter at fluidizing rates ranging from approximately 0.5 x G{sub mf} (packed bed condition) to over 10 x G{sub mf} using aluminum oxide sand particles ranging from d{sub p}=145-330 {mu}m (50-90 grit). It has been found that for all cylinder sizes tested, the Nusselt number reaches a maximum near 2 x G{sub mf}, then remains relatively steady ({+-}5-10%) to the maximum fluidizing rate tested, typically 8-12xG{sub mf}. A correlation for maximum Nusselt number is developed.« less
Mapping the droplet transfer modes for an ER100S-1 GMAW electrode
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heald, P.R.; Madigan, R.B.; Siewert, T.A.
1994-02-01
Welds were made with a 1.2-mm-diameter AWS ER100S-1 electrode using Ar-2% O[sub 2] shielding gas to map the effects of contact-tube-to-work distance (13, 19 and 25 mm), current, voltage, and wire feed rate on metal transfer. The droplet transfer modes were identified for each map by both the sound of the arc and images from a laser back-lit high-speed video system. The modes were correlated to digital records of the voltage and current fluctuations. The maps contain detailed information on the spray transfer mode, including the boundaries of drop spray, streaming spray and rotating spray modes. The metal transfer modemore » boundaries shifted with an increase in contact-tube-to-work distance. Increasing the contact-tube-to-work distance from 13 to 19 mm resulted in a 15 mm/s increase in the wire feet rate for the globular-to-drop-spray transition.« less
Numerical investigation of combustion phenomena in pulse detonation engine with different fuels
NASA Astrophysics Data System (ADS)
Alam, Noor; Sharma, K. K.; Pandey, K. M.
2018-05-01
The effects of different fuel-air mixture on the cyclic operation of pulse detonation engine (PDE) are numerically investigated. The present simulation is to be consider 1200 mm long straight tube combustor channel and 60 mm internal diameter, and filled with stoichiometric ethane-air and ethylene-air (C2H6-air & C2H4) fuel mixture at atmospheric pressure and temperature of 0.1 MPa and 300 K respectively. The obstacles of blockage ratio (BR) 0.5 and having 60 mm spacing among them are allocated inside the combustor tube. There are realizable k-ɛ turbulence model used to analyze characteristic of combustion flame. The objective of present simulation is to analyze the variation in combustion mechanism for two different fuels with one-step reduced chemical reaction model. The obstacles were creating perturbation inside the PDE tube. Therefore, flame surface area increases and reduces deflagration-to-detonation transition (DDT) run-up length.
Francis, P; Eastwood, K W; Bodani, V; Looi, T; Drake, J M
2018-05-07
This work explores the feasibility of creating and accurately controlling an instrument for robotic surgery with a 2 mm diameter and a three degree-of-freedom (DoF) wrist which is compatible with the da Vinci platform. The instrument's wrist is composed of a two DoF bending notched-nitinol tube pattern, for which a kinematic model has been developed. A base mechanism for controlling the wrist is designed for integration with the da Vinci Research Kit. A basic teleoperation task is successfully performed using two of the miniature instruments. The performance and accuracy of the instrument suggest that creating and accurately controlling a 2 mm diameter instrument is feasible and the design and modelling proposed in this work provide a basis for future miniature instrument development.
Pool boiling of nanofluids on rough and porous coated tubes: experimental and correlation
NASA Astrophysics Data System (ADS)
Cieśliński, Janusz T.; Kaczmarczyk, Tomasz Z.
2014-06-01
The paper deals with pool boiling of water-Al2O3 and water- Cu nanofluids on rough and porous coated horizontal tubes. Commercially available stainless steel tubes having 10 mm outside diameter and 0.6 mm wall thickness were used to fabricate the test heater. The tube surface was roughed with emery paper 360 or polished with abrasive compound. Aluminium porous coatings of 0.15 mm thick with porosity of about 40% were produced by plasma spraying. The experiments were conducted under different absolute operating pressures, i.e., 200, 100, and 10 kPa. Nanoparticles were tested at the concentration of 0.01, 0.1, and 1% by weight. Ultrasonic vibration was used in order to stabilize the dispersion of the nanoparticles. It was observed that independent of operating pressure and roughness of the stainless steel tubes addition of even small amount of nanoparticles augments heat transfer in comparison to boiling of distilled water. Contrary to rough tubes boiling heat transfer coefficient of tested nanofluids on porous coated tubes was lower compared to that for distilled water while boiling on porous coated tubes. A correlation equation for prediction of the average heat transfer coefficient during boiling of nanofluids on smooth, rough and porous coated tubes is proposed. The correlation includes all tested variables in dimensionless form and is valid for low heat flux, i.e., below 100 kW/m2.
High-intensity soft-flash x-ray generator utilizing a low-vacuum diode
NASA Astrophysics Data System (ADS)
Isobe, Hiroshi; Sato, Eiichi; Shikoda, Arimitsu; Takahashi, Kei; Tamakawa, Yoshiharu; Yanagisawa, Toru
1991-04-01
The fundamental studies on the high-intensity single flash x-ray generator having a low-vacuum diode for biomedical radiography are described. This generator consisted of the following essential components: a high-voltage power supply, a high-voltage pulser with a coaxial oil condenser of l5OnF, a low impedance transmission line made from four coaxial cables with lengths of 5. 6m and a total capacity of 292OpF, a mechanical booster pump, and a flash x-ray tube. The x-ray tube was of the diode-type which was connected to the booster pump with a constant pressure of 1. 7Pa and consisted of the following major devices: a long anode tip made of tungsten with a diameter (D) of less than 3. 0mm and a length (L) of 50mm, a long cathode tip made of tungsten with a D of 1. 0mm and a L of 40mm, a polyoxymethylene insulator, lead diaphragms, and an x-ray window made of polyethylene terephthalate. The coaxial oil condenser in the pulser was charged from 50 to 90kV, and the electric charges in the condenser were discharged to the flash x-ray tube through a transmission line by using a gas gap switch with a highcurrent capacity. The peak voltage increased according to increases in the condenser charged voltage and its value was more than the charged voltage. The peak current primarily increased when the charged voltage was increased, and its value was less than 4OkA. The pulse width of the flash x-rays ranged from 60 to 8Ons, and the time integrated x-ray intensity with a charged voltage of 90kV and an anode cathode (A-C) space of 3. 0mm was about 4pC/kg at 1. Om per pulse the source. The effective focal spot size was primarily determined by the diameter of the anode tip, and its value was about 3. 0mm when an anode diameter of 3. 0mm was employed.
Heat transfer and hydrodynamic investigations of a baffled slurry bubble column
NASA Astrophysics Data System (ADS)
Saxena, S. C.; Chen, Z. D.
1992-09-01
Heat transfer and hydrodynamic investigations have been conducted in a 0.108 m internal diameter bubble column at ambient conditions. The column is equipped with seven 19mm diameter tubes arranged in an equilateral triangular pitch of 36.5 mm. A Monsanto synthetic heat transfer fluid, Therminol-66 having a viscosity of 39.8 cP at 303 K, is used as a liquid medium. Magnetite powders, average diameters 27.7 and 36.6 µm, in five concentrations up to 50 weight percent in the slurry, are used. As a gas phase, industrial grade nitrogen of purity 99.6 percent is employed. Gas holdup in different operating modes and regimes have been measured for the two- and three-phase systems over a superficial gas velocity range up to 0.20 m/s in the semi-batch mode. Heat transfer coefficients are measured at different tube locations in the bundle at different radial and vertical locations over a range of operating conditions. All these data are compared with the existing literature correlations and models. New correlations are proposed.
Sirirat, Natnicha; Tetbuntad, Kornrawee; Siripinyanond, Atitaya
2017-03-01
Thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) was applied to investigate the time-dependent absorption peak profile of various forms of silver. The thermospray flame furnace was set up with a 10-cm-long nickel tube with six holes, each 2.0 mm in diameter, to allow the flame to enter, and this nickel tube acted as a furnace. A sample of 300 μL was introduced into this furnace by use of water as a carrier at a flow rate of 0.5 mL min -1 through the ceramic capillary (0.5-mm inner diameter and 2.0-mm outer diameter), which was inserted into the front hole of the nickel tube. The system was applied to examine atomization behaviors of silver nanoparticles (AgNPs) with particle sizes ranging from 10 to 100 nm. The atomization rate of AgNPs was faster than that of the dissolved silver ion. With increased amount of silver, the decay time observed from the time-dependent absorption peak profile was shortened in the case of dissolved silver ion, but it was increased in the case of AgNPs. With the particle size ranging from 10 to 100 nm, the detection sensitivity was indirectly proportional to the particle size, suggesting that TS-FF-AAS may offer insights into the particle size of AgNPs provided that the concentration of the silver is known. To obtain quantitative information on AgNPs, acid dissolution of the particles was performed before TS-FF-AAS analysis, and recoveries of 80-110% were obtained.
NASA Astrophysics Data System (ADS)
Zhou, Rui; Yu, Liu; Xie, Huangjun; Qiu, Limin; Zhi, Xiaoqin; Zhang, Xiaobin
2018-07-01
The theoretical approach for the prediction of flooding velocity based on the concept of hyperbolicity breaking was evaluated in the counter-current two-phase flow. Detailed mathematical derivations of neutral stability condition together with the correlation of the void fraction are presented. The flooding velocity is obtained by assuming that the wavelength at flooding is proportional to the wavelength of the fastest-growing wave at Helmholtz instability. Some available experimental data for different fluid pair flow in inclined tubes is adopted for comparison with the theoretical calculations, which includes the data of water/air, aqueous oleic acid natrium solution/air, Aq. butanol 2%/air and kerosene/air in the published papers, as well as the liquid nitrogen/vapor nitrogen by the present authors. The comparison of flooding velocity proves that the approach can predict the flooding velocity with accepted accuracy for the water/air and liquid nitrogen/vapor nitrogen flow if the tube diameter is greater than 9 mm. While the diameter is smaller than 9 mm, regardless of the inclinations and the fluid pairs, the error becomes larger relative to the cases of diameter larger than 9 mm. The calculations for small diameter cases also fail to predict the critical liquid velocity at which the flooding velocity of gas reaches the maximum value, as revealed by the experiments. The reasons for the increased errors were qualitatively explained.
Catto, Valentina; Farè, Silvia; Cattaneo, Irene; Figliuzzi, Marina; Alessandrino, Antonio; Freddi, Giuliano; Remuzzi, Andrea; Tanzi, Maria Cristina
2015-09-01
To overcome the drawbacks of autologous grafts currently used in clinical practice, vascular tissue engineering represents an alternative approach for the replacement of small diameter blood vessels. In the present work, the production and characterization of small diameter tubular matrices (inner diameter (ID)=4.5 and 1.5 mm), obtained by electrospinning (ES) of Bombyx mori silk fibroin (SF), have been considered. ES-SF tubular scaffolds with ID=1.5 mm are original, and can be used as vascular grafts in pediatrics or in hand microsurgery. Axial and circumferential tensile tests on ES-SF tubes showed appropriate properties for the specific application. The burst pressure and the compliance of ES-SF tubes were estimated using the Laplace's law. Specifically, the estimated burst pressure was higher than the physiological pressures and the estimated compliance was similar or higher than that of native rat aorta and Goretex® prosthesis. Enzymatic in vitro degradation tests demonstrated a decrease of order and crystallinity of the SF outer surface as a consequence of the enzyme activity. The in vitro cytocompatibility of the ES-SF tubes was confirmed by the adhesion and growth of primary porcine smooth muscle cells. The in vivo subcutaneous implant into the rat dorsal tissue indicated that ES-SF matrices caused a mild host reaction. Thus, the results of this investigation, in which comprehensive morphological and mechanical aspects, in vitro degradation and in vitro and in vivo biocompatibility were considered, indicate the potential suitability of these ES-SF tubular matrices as scaffolds for the regeneration of small diameter blood vessels. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Ramani, Ajay
Glaucoma encompasses a group of conditions that result in damage to the optic nerve and can cause loss of vision and blindness. The nerve is damaged due to an increase in the eye's internal (intraocular) pressure (IOP) above the nominal range of 15 -- 20 mm Hg. There are many treatments available for this group of diseases depending on the complexity and stage of nerve degradation. In extreme cases where drugs or laser surgery do not create better conditions for the patient, ophthalmologists use glaucoma drainage devices to help alleviate the IOP. Many drainage implants have been developed over the years and are in use; but two popular implants are the Baerveldt Glaucoma Implant and the Ahmed Glaucoma Valve Implant. Baerveldt Implants are non-valved and provide low initial resistance to outflow of fluid, resulting in post-operative complications such as hypotony, where the IOP drops below 5 mm of Hg. Ahmed Glaucoma Valve Implants are valved implants which initially restrict the amount of fluid flowing out of the eye. The long term success rates of Baerveldt Implants surpass those of Ahmed Valve Implants because of post-surgical issues; but Baerveldt Implants' initial effectiveness is poor without proper flow restriction. This drives the need to develop new ways to improve the initial effectiveness of Baerveldt Implants. A possible solution proposed by our research team is to place an insert in the Baerveldt Implant tube of inner diameter 305 microns. The insert must be designed to provide flow resistance for the early time frame [e.g., first 30 -- 60 post-operative days] until sufficient scar tissue has formed on the implant. After that initial stage with the insert, the scar tissue will provide the necessary flow resistance to maintain the IOP above 5 mm Hg. The main objective of this project was to develop and validate an experimental apparatus to measure pressure drop across a Baerveldt Implant tube, with and without inserts. This setup will be used in the future to evaluate custom inserts and their effects on the pressure drop over 4 -- 6 weeks. The design requirements were: simulate physiological conditions [flow rate between 1.25 and 2.5 mul/min], evaluate small inner diameter tubes [50 and 75 mum] and annuli, and demonstrate reliability and repeatability. The current study was focused on benchmarking the experimental setup for the IOP range of 15 -- 20 mm Hg. Repeated experiments have been conducted using distilled water with configurations [diameter of tube, insert diameter, lengths of insert and tube, and flow rate] that produce pressure variations which include the 15 -- 20 mm Hg range. Two similar setups were assembled and evaluated for repeatability between the two. Experimental measurements of pressure drop were validated using theoretical calculations. Theory predicted a range of expected values by considering manufacturing and performance tolerances of the apparatus components: tube diameter, insert diameter, and the flow-rate and pressure [controlled by pump]. In addition, preliminary experiments evaluated the dissolution of suture samples in a balanced salt solution and in distilled water. The balanced salt solution approximates the eye's aqueous humor properties, and it was expected that the salt and acid would help to hydrolyze sutures much faster than distilled water. Suture samples in a balanced salt solution showed signs of deterioration [flaking] within 23 days, and distilled water samples showed only slight signs of deterioration after about 30 days. These preliminary studies indicate that future dissolution and flow experiments should be conducted using the balanced salt solution. Also, the absorbable sutures showed signs of bulk erosion/deterioration in a balanced salt solution after 14 days, which indicates that they may not be suitable as inserts in the implant tubes because flakes could block the tube entrance. Further long term studies should be performed in order to understand the effects of constant fluid movement over the surfaces of the absorbable sutures, by better means of rocking/shaking test suture samples to simulate flow conditions. (Abstract shortened by UMI.).
A new high-resolution PET scanner dedicated to brain research
NASA Astrophysics Data System (ADS)
Watanabe, M.; Shimizu, K.; Omura, T.; Takahashi, M.; Kosugi, T.; Yoshikawa, E.; Sato, N.; Okada, H.; Yamashita, T.
2002-06-01
A high-resolution positron emission tomography (PET) scanner dedicated to brain studies has been developed and its physical performance was evaluated. The block detector consists of a new compact position-sensitive photomultiplier tube (PS-PMT, Hamamatsu R7600-C12) and an 8/spl times/4 bismuth germanate (BGO) array. The size of each crystal is 2.8 mm/spl times/6.55 mm/spl times/30 mm. The system has a total of 11 520 crystals arranged in 24 detector rings 508 mm in diameter (480 per ring). The field of view (FOV) is 330 mm in diameter/spl times/163 mm, which is sufficient to measure the entire human brain. The diameter of the scanner's opening is equal to the transaxial FOV (330 mm). The system can be operated in three-dimensional (3-D) data acquisition mode, when the slice septa are retracted. The mechanical motions of the gantry and bed are specially designed to measure the patient in various postures; lying, sitting, and even standing postures. The spatial resolution of 2.9 mm in both the transaxial and axial directions is obtained at the center of the FOV. The total system sensitivity is 6.4 kc/s/kBq/ml in two-dimensional (2-D) mode, with a 20-cm-diameter cylindrical phantom. The imaging capabilities of the scanner were studied with the Hoffman brain phantom and with a normal volunteer.
Measurement and analysis of a small nozzle plume in vacuum
NASA Technical Reports Server (NTRS)
Penko, P. F.; Boyd, I. D.; Meissner, D. L.; Dewitt, K. J.
1993-01-01
Pitot pressures and flow angles are measured in the plume of a nozzle flowing nitrogen and exhausting to a vacuum. Total pressures are measured with Pitot tubes sized for specific regions of the plume and flow angles measured with a conical probe. The measurement area for total pressure extends 480 mm (16 exit diameters) downstream of the nozzle exit plane and radially to 60 mm (1.9 exit diameters) off the plume axis. The measurement area for flow angle extends to 160 mm (5 exit diameters) downstream and radially to 60 mm. The measurements are compared to results from a numerical simulation of the flow that is based on kinetic theory and uses the direct-simulation Monte Carlo (DSMC) method. Comparisons of computed results from the DSMC method with measurements of flow angle display good agreement in the far-field of the plume and improve with increasing distance from the exit plane. Pitot pressures computed from the DSMC method are in reasonably good agreement with experimental results over the entire measurement area.
Gravity-Independent Mobility and Drilling on Natural Rock using Microspines
NASA Technical Reports Server (NTRS)
Parness, Aaron; Frost, Matthew; Thatte, Nitish; King, Jonathan P.
2012-01-01
To grip rocks on the surfaces of asteroids and comets, and to grip the cliff faces and lava tubes of Mars, a 250 mm diameter omni-directional anchor is presented that utilizes a hierarchical array of claws with suspension flexures, called microspines, to create fast, strong attachment. Prototypes have been demonstrated on vesicular basalt and a'a lava rock supporting forces in all directions away from the rock. Each anchor can support >160 N tangent, >150 N at 45?, and >180 N normal to the surface of the rock. A two-actuator selectively- compliant ankle interfaces these anchors to the Lemur IIB robot for climbing trials. A rotary percussive drill was also integrated into the anchor, demonstrating self-contained rock coring regardless of gravitational orientation. As a harder- than-zero-g proof of concept, 20mm diameter boreholes were drilled 83 mm deep in vesicular basalt samples, retaining a 12 mm diameter rock core in 3-6 pieces while in an inverted configuration, literally drilling into the ceiling.
R245fa Flow Boiling inside a 4.2 mm ID Microfin Tube
NASA Astrophysics Data System (ADS)
Longo, G. A.; Mancin, S.; Righetti, G.; Zilio, C.
2017-11-01
This paper presents the R245fa flow boiling heat transfer and pressure drop measurements inside a mini microfin tube with internal diameter at the fin tip of 4.2 mm, having 40 fins, 0.15 mm high with a helix angle of 18°. The tube was brazed inside a copper plate and electrically heated from the bottom. Sixteen T-type thermocouples are located in the copper plate to monitor the wall temperature. The experimental measurements were carried out at constant mean saturation temperature of 30 °C, by varying the refrigerant mass velocity between 100 kg m-2 s-1 and 300 kg m-2 s-1, the vapour quality from 0.15 to 0.95, at two different heat fluxes: 30 and 60 kW m-2. The experimental results are presented in terms of two-phase heat transfer coefficient, onset dryout vapour quality, and frictional pressure drop. Moreover, the experimental measurements are compared against the most updated models for boiling heat transfer coefficient and frictional pressure drop estimations available in the open literature for microfin tubes.
NASA Technical Reports Server (NTRS)
Russell, G. R.
1976-01-01
Lasers utilizing atomic metallic vapors are considered with emphasis on a double discharge technique and multiply pulsed experiments. Data are presented on the effect of time delay after the first electrical discharge and the effect of lasant temperature along with results of absorption measurements utilizing a 13 mm diameter laser tube. Data obtained from multiply pulsed experiments for discharge diameters varying from 1 to 4 cm indicate that the efficiency increases with the pulsing rate.
Evaluation of alternative dowel bar materials and coatings.
DOT National Transportation Integrated Search
2011-11-01
This study provided for a continuation of the long-term performance evaluation of 1.5-in (38-mm) diameter FRP dowels : and Type 304 stainless steel solid dowels or mortar-filled tubes compared to epoxy-coated dowels. This primarily : included an eval...
A TWT upgrade to study wave-particle interactions in plasma
NASA Astrophysics Data System (ADS)
Doveil, Fabrice; Caetano de Sousa, Meirielen; Guyomarc'h, Didier; Kahli, Aissa; Elskens, Yves
2015-11-01
Beside industrial applications, Traveling Wave Tubes (TWT) are useful to mimic and study wave-particle interaction in plasma. We upgraded a TWT, whose slow wave structure is a 4 m long helix (diameter 3.4 cm, pitch 1 mm) of Be-Cu wire (diameter 0.6 mm) wrapped in insulating tape. The helix is inserted in a vacuum glass tube. At one end, an electron gun produces a beam propagating along the helix, radially confined by a constant axial magnetic field. Movable probes, capacitively coupled to the helix through the glass tube, launch and monitor waves generated by an arbitrary waveform generator at a few tens of MHz. At the other end of the helix, a trochoidal analyzer allows to reconstruct the electron distribution functions of the beam after its self-consistent interaction with the waves. Linear properties of the new device will be reported. The measured coupling coefficients of each probe with the helix are used to reconstruct the growth and saturation of a launched wave as it interacts with the electron beam. J-B. Faure and V. Long are thanked for their efficient help in designing and using a new way to build the helix.
The Effect of Muzzle Jet Asymmetry on Projectile Motion
1975-01-01
fixture was designed to provide invariant mechanical support to the gun tube while allowing control of the symmetry of the muzzle gar flow field...Figure 4. A 2S4mm diameter by 12.7mm thick (non-metric dimensions: 10 in x 1/2 in) aluminum base plate is press fit onto the muzzle of a 6.71mm...indicated by the opaque regions of concentrated powder particles. The muzzle flow at a considerably later time, Figure 1, shows the projectile to be
Takimoto, Y; Okumura, N; Nakamura, T; Natsume, T; Shimizu, Y
1993-01-01
This study investigated ways of preventing late stenosis after replacing the esophagus with a prosthetic device and increasing survival time in an animal model. In a previous study, the authors induced neoesophageal formation and re-epithelialization at an early stage, although stenosis in the chronic stage remained a problem, and long-term survival was prevented. The authors developed an artificial esophagus made from a collagen-silicone composite tube. The silicone tube (25 mm in diameter, 50 mm long, and 1 mm thick) was covered with collagen sponge (5 mm thick). The collagen sponge was intended to be replaced by host tissue, leading to neoesophageal regeneration. The authors thought stenosis was caused primarily by poor regeneration of submucosal tissue, rather than reepithelialization. Thus, they examined the grade of stenosis relative to the time the stent became dislodged. They concluded that the occurrence of stenosis after anastomosis depends upon the duration of stenting and that stenosis did not develop when the portion replaced by the artificial esophagus was stented for at least 4 weeks.
NASA Technical Reports Server (NTRS)
Barr, Francis A.; Page, Russell J.
1987-01-01
The adaptation of the powdered particle process used for pure metal oxides to the coprocessing of rhenium oxides suitable to produce pure miniature resistojet hardware has been successful. Both slip casting and extrusion processes were used. The metal oxide ZrO2 was stabilized into the cubic phase with Y2O3, for use as a potentially grain stabilizing additive to rhenium. Straight meter long tubing in two sizes are reported. Tubing suitable for resistojet ohmic heater use of fully fired dimensions of nominally 3.8 mm o.d. x 2.2 mm i.d.. and 1.26 mm o.d. x .45 mm i.d. with 0, 0.5, 1.0 and 5.0% zirconia additives were produced for further study. Photomicrographs of these are discussed. The addition of the metal oxide zirconia to rhenium resulted in more dense and less porous parts. The additions of phase stabilized zirconia most likely act as a sintering aid. Tubes of varying diameter were slip cast which were representative of miniature pressure cases.
Ohashi, Nobuko; Imai, Hidekazu; Seino, Yutaka; Baba, Hiroshi
2017-12-06
Determination of the appropriate tracheal tube size using formulas based on age or height often is inaccurate in pediatric patients with congenital heart disease (CHD), particularly in those with high pulmonary arterial pressure (PAP). Here, the authors compared tracheal diameters between pediatric patients with CHD with high PAP and low PAP. Retrospective clinical study. Hospital. Pediatric patients, from birth to 6 months of age, requiring general anesthesia and tracheal intubation who underwent computed tomography were included. Patients with mean pulmonary artery pressure >25 mmHg were allocated to the high PAP group, and the remaining patients were allocated to the low PAP group. The primary outcome was the tracheal diameter at the cricoid cartilage level, and the secondary goal was to observe whether the size of the tracheal tube was appropriate compared with that obtained using predictable formulas based on age or height. The mean tracheal diameter was significantly larger in the high PAP group than in the low PAP group (p < 0.01). Pediatric patients with high PAP required a larger tracheal tube size than predicted by formulas based on age or height (p = 0.04 for age and height). Pediatric patients with high PAP had larger tracheal diameters than those with low PAP and required larger tracheal tubes compared with the size predicted using formulas based on age or height. Copyright © 2017 Elsevier Inc. All rights reserved.
Lundgren, Dan; Slotte, Christer; Gröndahl, Kerstin
2013-08-01
Alternative implant designs may reduce the need for complicated and costly bone augmentation procedures in situations with limited bone height. Wide dental tube implants have been manufactured and tested in three patients and followed for 5 years to evaluate if such implants are capable to support fixed prosthetic constructions with good prognosis in areas with limited bone height. Four machined-tube implants with a height of 6 mm, an outer diameter of 7.4 mm, and an inner diameter of 6.0 mm were placed in three patients. After a healing period of 3 months, ceramometal suprastructures were constructed to supply the implants. Annual clinical and radiographical follow-ups were done up to 5 years. At the 5-year follow-up, all three patients were examined with a cone beam computed tomography technique. All implants and the suprastructures were clinically stable after 5 years. In one patient, vertical bone loss and a 6-mm deep pocket appeared after 1 year. The pocket has remained throughout the observation period and has been regularly debrided and kept it free from clinical signs of inflammation. In the other two patients, the soft tissue surrounding the implants was in good health with no or only slight inflammation throughout all observations. Pocket probing revealed no or slight bleeding and pocket depths amounting to less than 3 mm. It was shown that this new type of implant will function excellent during follow-up times of several years. Further studies should be done to explore in more detail indications for such implants. © 2011 Wiley Periodicals, Inc.
Coherent anti-Stokes Raman scattering rigid endoscope toward robot-assisted surgery.
Hirose, K; Aoki, T; Furukawa, T; Fukushima, S; Niioka, H; Deguchi, S; Hashimoto, M
2018-02-01
Label-free visualization of nerves and nervous plexuses will improve the preservation of neurological functions in nerve-sparing robot-assisted surgery. We have developed a coherent anti-Stokes Raman scattering (CARS) rigid endoscope to distinguish nerves from other tissues during surgery. The developed endoscope, which has a tube with a diameter of 12 mm and a length of 270 mm, achieved 0.91% image distortion and 8.6% non-uniformity of CARS intensity in the whole field of view (650 μm diameter). We demonstrated CARS imaging of a rat sciatic nerve and visualization of the fine structure of nerve fibers.
Compton spectroscopy in the diagnostic x-ray energy range. I. Spectrometer design.
Matscheko, G; Carlsson, G A
1989-02-01
The optimal design of a Compton spectrometer for measuring photon energy spectra from x-ray tubes in a clinical laboratory is analysed. The demands are: (i) coherent and multiple scattering distort the measurements and must be avoided; (ii) the measuring time should be as short as possible to avoid unnecessary wear on the x-ray tube; and (iii) the impairment in energy resolution due to the scattering geometry should be kept minimal. A scattering angle of 90 degrees is advocated. Scatterers (of low-atomic-number material) in the shape of long circular rods (0.5-4 mm diameter, 20-40 mm long) are preferable to scattering foils. Use of a short focus-scatterer distance (approximately 200 mm) is to be preferred compared to using a large detector area (greater than or equal to 4 mm diameter) in order to establish a sufficiently high count rate in the detector. Short focal distances and a 90 degrees scattering angle are advantages in measuring energy spectra in the gantry of CT machines where the available space is limited. To limit the geometrical energy broadening to less than 1 keV, the spread in scattering angles of registered photons must not exceed 1-2 degrees for incident photon energies of 100-150 keV.
NASA Technical Reports Server (NTRS)
Barr, F. A.; Page, R. J.
1986-01-01
The feasibility of fabricating small rhenium parts with metal oxide additives by means of slip casting and extrusion techniques is described. The metal oxides, ZrO2 and HfO2 were stabilized into the cubic phase with Y2O3. Additions of metal oxide to the rhenium of up to 15 weight percent were used. Tubes of 17 mm diameter with 0.5 mm walls were slip cast by adapting current ceramic oxide techniques. A complete cast double conical nozzle demonstrated the ability to meet shapes and tolerances. Extrusion of meter long tubing lengths of 3.9 mm o.d. x 2.3 mm i.d. final dimension is documented. Sintering schedules are presented to produce better than 95% of theoretical density parts. Finished machining was found possible were requried by electric discharge machining and diamond grinding.
Development of a probe for inner profile measurement and flaw detection
NASA Astrophysics Data System (ADS)
Yoshizawa, Toru; Wakayama, Toshitaka; Kamakura, Yoshihisa
2011-08-01
It is one of the important necessities to precisely measure the inner diameter and/or the inner profile of pipes, tubes and other objects similar in shape. Especially in mechanical engineering field, there are many requests from automobile industry because the inner surface of engine blocks and other die casts are strongly required to be inspected and measured by non-contact methods (not by the naked eyes inspection using a borescope). If the inner diameter is large enough like water pipes or drain pipes, complicated and large equipment may be applicable. However, small pipes with a diameter ranging from 10mm to 100mm are difficult to be inspected by such a large instrument as is used for sewers inspection. And we have proposed an instrument which has no moving elements such as a rotating mirror or a prism for scanning a beam. Our measurement method is based on optical sectioning using triangulation. This optically sectioned profile of an inner wall of pipe-like objects is analyzed to produce numerical data of inner diameter or profile. Here, we report recent development of the principle and applications of the optical instrument with a simple and compact configuration. In addition to profile measurement, we found flaws and defects on the inner wall were also detected by using the similar principle. Up to now, we have developed probes with the diameter of 8mm to 25mm for small size objects and another probe (80 mm in diameter) for such a larger container with the dimensional size of 600mm.
NASA Astrophysics Data System (ADS)
Seibel, Eric J.
2008-02-01
Flexible endoscopes use one sensor element per display pixel. When diameter is reduced to the size of a catheter, there is a significant reduction in the number of pixels within the image. By placing a sub-millimeter microscanner at the tip of a catheter, image quality can be significantly improved. The microscanner consists of a 0.4 mm diameter piezoelectric tube with quadrant electrodes, surrounding a cantilevered singlemode optical fiber. At the distal end, the fiber microscanner is sealed with a 0.9 mm diameter lens assembly, creating a rigid length less than 10 mm at the tip of a highly flexible shaft. The cantilevered fiber is vibrated at the first mode of resonance for bending to generate a circular scan pattern. A spiral scan pattern is generated that constitutes an image frame by modulating the piezoelectric drive signals. By using a custom optical fiber at 80 microns cladding diameter, >10 KHz resonant scanning is achieved, resulting in a 30 Hz frame rate. Red (635 nm), green (532 nm), and blue (442 nm) laser light is scanned by coupling to the fiber scanner. The scanned illumination is detected in a non-confocal arrangement by having one or more optical fibers collecting the backscattered light at MHz pixel rates. Current 1-mm diameter catheterscopes generate 500-line images at maximum fields of view of 100 degrees and spatial resolutions of <20 microns with image zooming. Shaft length of four meters have been fabricated with flexibility of <10 mm bending radius to image previously inaccessible regions of the body.
Indirect Measurement of Local Condensing Heat-Transfer Coefficient Around Horizontal Finned Tubes
1987-09-01
vapor-sidp coefficients exceeded Nusselt values by factors of approximately 7 to 9 (for a constant temperature drop across the condensate film). Honda...3/8 in.) diameter water-cooled copper tubes helically coiled to a height of 457 mm (le In.). The auxiliary condenser was cooled by a continuous...NAVAL POSTGRADUATE SCHOOL Monterey, California , " I - . 0) I DECI 41987S:,• c ý ! i, THESIS INDIRECT MEASUREMENT OF LOCAL CONDENSING HEAT-TRANSFER
Orthodontic miniplate with tube as an efficient tool for borderline cases.
Chung, Kyu-Rhim; Kim, Seong-Hun; Kang, Yoon-Goo; Nelson, Gerald
2011-04-01
An orthodontic miniplate tube device, the C-tube, was designed for use in patients for whom a conventional miniscrew is not suitable, such as those with narrow interradicular spaces, extended maxillary sinuses, dilacerated roots, or severe alveolar bone loss. After local anesthesia, 2 parallel horizontal incisions are made in the area of placement, and the periosteum is elevated. The C-tube is slipped under the mucosal flap and fixed with self-drilling miniscrews (diameter, 1.5 mm; length, 4 mm). Because the screws are short, there is adequate retention in the alveolar plate, and the clinician can avoid the increased morbidity of anchoring to the zygomatic buttress. This makes placement possible with superficial anesthesia. A small rolled tube at the head part can act as an orthodontic tube and accommodate archwires or as a hook to attach orthodontic elastics. However, in some patients with pneumatization or systemic diseases, such as diabetes mellitus, or in heavy smokers, cross-type C-tubes with longer miniscrews are recommend for better stability. This new type of orthodontic miniplate can be an effective alternative to conventional 1-component screws or miniplates in complex situations. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Fekete, Szabolcs; Guillarme, Davy
2018-02-05
The goal of the study was to evaluate the impact of connection tubing in modern size exclusion chromatography (SEC), since it may strongly impact the apparent column efficiency, as the compounds are not retained in SEC. For this purpose, a reference SEC column of 150×4.6mm, 1.8μm was considered, and various proteins were tested as model compounds. Different tube geometries (lengths and internal diameters) and materials (stainless steel and PEEK) were evaluated in a systematic way. Large proteins always showed larger tube dispersion vs. small molecules, especially when the residence time in the tube was long (at low flow rate). This confirms the need to drastically reduce the tube volume (using the shortest and narrowest connector tubing) to attain the full benefits of UHPSEC columns. In addition, PEEK tubing were found to be more appropriate than stainless steel tubing, since adsorption of proteins was less pronounced, and higher plate count can be obtained. Finally, after a careful system optimization, up to 40% increase of apparent column efficiency can be achieved compared to a regular UHPLC system, when using a 150×4.6mm UHPSEC columns packed with sub-3μm particles. Copyright © 2017 Elsevier B.V. All rights reserved.
A canine model of tracheal stenosis induced by cuffed endotracheal intubation
Su, Zhuquan; Li, Shiyue; Zhou, Ziqing; Chen, Xiaobo; Gu, Yingying; Chen, Yu; Zhong, Changhao; Zhong, Minglu; Zhong, Nanshan
2017-01-01
Postintubation tracheal stenosis is a complication of endotracheal intubation. The pathological mechanism and risk factors for endotracheal intubation-induced tracheal stenosis remain not fully understood. We aimed to establish an animal model and to investigate risk factors for postintubation tracheal stenosis. Beagles were intubated with 4 sized tubes (internal diameter 6.5 to 8.0 mm) and cuff pressures of 100 to 200 mmHg for 24 hr. The status of tracheal wall was evaluated by bronchoscopic and histological examinations. The model was successfully established by cuffed endotracheal intubation using an 8.0 mm tube and an intra-cuff pressure of 200 mmHg for 24 hr. When the intra-cuff pressures were kept constant, a larger sized tube would induce a larger tracheal wall pressure and more severe injury to the tracheal wall. The degree of tracheal stenosis ranged from 78% to 91% at 2 weeks postextubation. Histological examination demonstrated submucosal infiltration of inflammatory cells, hyperplasia of granulation tissue and collapse of tracheal cartilage. In summary, a novel animal model of tracheal stenosis was established by cuffed endotracheal intubation, whose histopathological feathers are similar to those of clinical cases of postintubation tracheal stenosis. Excessive cuff pressure and over-sized tube are the risk factors for postintubation tracheal stenosis. PMID:28349955
Boiling and condensation in microfin tubes
NASA Astrophysics Data System (ADS)
Schlager, Lynn M.
A general overview of microfin tubes and their applications is presented. Manufacturing processes, commercial availability, experimental heat transfer, and pressure drop data for various refrigerants (including alternative refrigerants and refrigerant-oil mixtures), physical mechanisms of enhancement, and the incorporation of microfin tubes in common heat exchanger configurations are discussed. Microfin tubes, also known by various trade names, are characterized by numerous small fins which typically spiral down the inside wall of tubes at angles ranging from 10 to 30 degrees. The number of fins ranges from 48 to 70 with typical fin heights of 0.12 to 0.30 mm (fin height generally less than 3 percent of the inside diameter of the tube). Fin shapes may vary and the inside surface area of microfin tubes is 10 to 70 percent greater than the area of equivalent smooth tubes. Heat transfer can be enhanced by up to a factor of three with microfin tubes.
Miscible displacement of a non-Newtonian fluid in a capillary tube
NASA Astrophysics Data System (ADS)
Soori, Tejaswi; Ward, Thomas
2017-11-01
This talk focuses on experiments conducted to further our understanding of how to displace an aqueous polymer within a capillary tube (diameter < 1 mm) using a Newtonian fluid. Estimates of the residual film were measured as a function of Reynolds (Re), viscous Atwood (At) and Péclet (Pé) numbers. Aqueous polymers were prepared by mixing ϕ = 0.01-0.1% (wt/wt) Carboxymethyl Cellulose (CMC) in water. We measure the shear viscosity of the aqueous polymer over a broad range of shear rates and fit the data obtained to the Carreau fluid parameters. Separately we measure the average bulk diffusion coefficient of the aqueous polymer and water in water and aqueous polymer phases respectively. Previous studies on the immiscible displacement of polymers have shown residual film thickness to be dependent on the tube diameter. We will investigate if this is true when the two fluids are miscible in nature. American Chemical Society Petroleum Research Fund.
The FINUDA straw tube detector
NASA Astrophysics Data System (ADS)
Zia, A.; Benussi, L.; Bertani, M.; Bianco, S.; Fabbri, F. L.; Gianotti, P.; Giardoni, M.; Lucherini, V.; Mecozzi, A.; Pace, E.; Passamonti, L.; Qaiser, N.; Russo, V.; Tomassini, S.; Sarwar, S.; Serdyouk, V.
2001-04-01
An array of 2424 2.6- m-long, 15- mm-diameter mylar straw tubes, arranged in two axial and four stereo layers, has been assembled at National Laboratories of Frascati of INFN for the FINUDA experiment. The array covers a cylindrical tracking surface of 18 m 2 and provides coordinate measurement in the drift direction and along the wire with a resolution of the order of 100 and 300 μm, respectively. The array has finished the commissioning phase and tests with cosmic rays are underway. The status straw tubes array and a very preliminary result from cosmic rays test are summarized in this work.
Leakage of fluid in different types of tracheal tubes.
Winklmaier, U; Wüst, K; Schiller, S; Wallner, F
2006-10-01
The aim of this study was to evaluate leakage of liquids, i.e., water and saliva, past low-pressure cuffs of tracheostomy tubes. Three different types of tracheostomy tubes, TRACOE vario (TRACOE Medical GmbH, Germany), Rüsch Ultra-Tracheoflex (Rüsch GmbH, Germany), and Portex Blue Line Ultra (Smiths Medical, UK) were tested in isolated pig tracheas. Sixty samples (10 tubes each of 7- and 8-mm inner diameter of each type) were used. Four different experiments were devised: type 1 (water and artificial ventilation), type 2 (water and no artificial ventilation), type 3 (saliva and artificial ventilation), and type 4 (saliva and no artificial ventilation). Six milliliters of water or artificial saliva were infused over the cuff and the volume of fluid that leaked past the cuff was measured after 5, 10, and 15 min. Intracuff pressure was also measured three times. The saliva experiments resulted in less leakage than the water experiments. Leakage after treatment with water or artificial saliva is higher without artificial ventilation than with ventilation. The amount of leakage among the tubes with respect to manufacturer showed statistically significant results. However, there were no differences among tracheostomy tubes with respect to internal diameter.
Development of Minimally Invasive Medical Tools Using Laser Processing on Cylindrical Substrates
NASA Astrophysics Data System (ADS)
Haga, Yoichi; Muyari, Yuta; Goto, Shoji; Matsunaga, Tadao; Esashi, Masayoshi
This paper reports micro-fabrication techniques using laser processing on cylindrical substrates for the realization of high-performance multifunctional minimally invasive medical tools with small sizes. A spring-shaped shape memory alloy (SMA) micro-coil with a square cross section has been fabricated by spiral cutting of a Ti-Ni SMA tube with a femtosecond laser. Small diameter active bending catheter which is actuated by hydraulic suction mechanism for intravascular minimally invasive diagnostics and therapy has also been developed. The catheter is made of a Ti-Ni super elastic alloy (SEA) tube which is processed by laser micromachining and a silicone rubber tube which covers the outside of the SEA tube. The active catheter is effective for insertion in branch of blood vessel which diverse in acute angle which is difficult to proceed. Multilayer metallization and patterning have been performed on glass tubes with 2 and 3 mm external diameters using maskless lithography techniques using a laser exposure system. Using laser soldering technique, a integrated circuit parts have been mounted on a multilayer circuit patterned on a glass tube. These fabrication techniques will effective for realization of high-performance multifunctional catheters, endoscopic tools, and implanted small capsules.
Noncontact measurement of high temperature using optical fiber sensors
NASA Technical Reports Server (NTRS)
Claus, R. O.
1990-01-01
The primary goal of this research program was the investigation and application of noncontact temperature measurement techniques using optical techniques and optical fiber methods. In particular, a pyrometer utilizing an infrared optical light pipe and a multiwavelength filtering approach was designed, revised, and tested. This work was motivated by the need to measure the temperatures of small metallic pellets (approximately 3 mm diameter) in free fall at the Microgravity Materials Processing Drop Tube at NASA Marshall Space Flight Center. In addition, research under this program investigated the adaptation of holography technology to optical fiber sensors, and also examined the use of rare-earth dopants in optical fibers for use in measuring temperature. The pyrometer development effort involved both theoretical analysis and experimental tests. For the analysis, a mathematical model based on radiative transfer principles was derived. Key parameter values representative of the drop tube system, such as particle size, tube diameter and length, and particle temperature, were used to determine an estimate of the radiant flux that will be incident on the face of an optical fiber or light pipe used to collect radiation from the incandescent falling particle. An extension of this work examined the advantage of inclining or tilting the collecting fiber to increase the time that the falling particle remains in the fiber field-of-view. Those results indicate that increases in total power collected of about 15 percent may be realized by tilting the fiber. In order to determine the suitability of alternative light pipes and optical fibers, and experimental set-up for measuring the transmittance and insertion loss of infrared fibers considered for use in the pyrometer was assembled. A zirconium fluoride optical fiber and several bundles of hollow core fiber of varying diameters were tested. A prototype two-color pyrometer was assembled and tested at Virginia Tech, and then tested on the Drop Tube at Marshall Space Flight Center. Radiation from 5 mm diameter niobium drops falling in the Drop Tube was successfully detected, and recorded for later analysis. Subsequent analysis indicated that the imaging of light output from the light pipe onto the detector active areas was not identical for both detectors.
NASA Astrophysics Data System (ADS)
Baba, Soumei; Sawada, Kenichiro; Kubota, Chisato; Kawanami, Osamu; Asano, Hitoshi; Inoue, Koichi; Ohta, Haruhiko
Recent increase in the size of space platforms requires the management of larger amount of waste heat under high heat flux conditions and the transportation of it along a long distance to the radiator. Flow boiling applied to the thermal management system in space attracts much attention as promising means to realize high-performance heat transfer and transport because of large latent heat of vaporization. In microgravity two-phase flow phenomena are quite different from those under 1-g condition because buoyancy effects are significantly reduced and surface tension becomes dominant. By the similar reason, flow boiling characteristics in mini channels are not the same as those in channels of normal sizes. In the present stage, however, the boundary between the regimes of body force dominated and of surface tension dominated is not clear. The design of space thermal devices, operated under the conditions where no effect of gravity is expected, will improve the reliability of their ground tests, provided that the boundaries of dominant force regimes are clarified quantitatively in advance. In flow boiling in mini channels or in parallel channels, back flow could be occurred because of rapid growth of bubbles in a confined space, resulting flow rate fluctuation. Flow boiling heat transfer characteristics in mini channels can be changed considerably by the existence of inlet flow rate fluctuation. It is important to pay attention to experimental accuracy and to use a single circular mini-tube to compare heat transfer characteristics with those of normal size tubes. In the present paper, effects of tube orientations, i.e. vertical upward flow, vertical downward flow and horizontal flow, on flow boiling heat transfer characteristics is investigated for FC72 flowing in single mini-tubes with inner diameters of 0.13 and 0.51 mm to establish a reliable dominant force regime map. If the regime map is described by using dimensionless groups of Bond, Weber and Froude numbers, the boundary of dominant forces of inertia and body force is examined by using the mini-tube of the larger diameter at constant Bond number Bo = 0.51, and the boundary of inertia and surface tension by using the mini-tube of smaller diameter at Bo = 0.033. The influence of inertia is varied by the change of vapor quality, i.e. ratio of vapor mass flow rate to the total, under constant mass velocities, where the velocity of liquid-vapor mixtures is increased with increasing vapor quality. For the tube diameter of 0.51 mm, under low inertia conditions at Froude number Fr < 5, heat transfer coefficients were influenced by the tube orientation, while the heat transfer coefficients were almost independent of the orientation for Fr > 5. The results indicated that the boundary between the body force dominated and the inertia force dominated regimes was given by Froude number as Fr ˜ 5. On the other hand, for tube diameter of 0.13 mm, almost no effect of tube = orientation was observed for all combinations of mass velocity and vapor quality, and heat transfer coefficients were independent of vapor quality under low inertia conditions at Weber number We < 5, and vice versa. The results implied the boundary between the surface tension dominated and the inertia force dominated regimes was represented by We ˜ 5. = In addition, by the reflection of both results on the two-dimensional regime map, the boundary between the surface tension dominated and the body force dominated regimes was approx-imately evaluated as Bo ˜ 0.25 from the crossing point of two boundary lines. This value = located in the range of 0.033 < Bo < 0.51 is consistent with the boundaries between the sur-face tension dominated and the body force dominated regimes classified for the smaller and larger mini-tubes, respectively, under low inertia conditions.
Oxy-acetylene driven laboratory scale shock tubes for studying blast wave effects
NASA Astrophysics Data System (ADS)
Courtney, Amy C.; Andrusiv, Lubov P.; Courtney, Michael W.
2012-04-01
This paper describes the development and characterization of modular, oxy-acetylene driven laboratory scale shock tubes. Such tools are needed to produce realistic blast waves in a laboratory setting. The pressure-time profiles measured at 1 MHz using high-speed piezoelectric pressure sensors have relevant durations and show a true shock front and exponential decay characteristic of free-field blast waves. Descriptions are included for shock tube diameters of 27-79 mm. A range of peak pressures from 204 kPa to 1187 kPa (with 0.5-5.6% standard error of the mean) were produced by selection of the driver section diameter and distance from the shock tube opening. The peak pressures varied predictably with distance from the shock tube opening while maintaining both a true blast wave profile and relevant pulse duration for distances up to about one diameter from the shock tube opening. This shock tube design provides a more realistic blast profile than current compression-driven shock tubes, and it does not have a large jet effect. In addition, operation does not require specialized personnel or facilities like most blast-driven shock tubes, which reduces operating costs and effort and permits greater throughput and accessibility. It is expected to be useful in assessing the response of various sensors to shock wave loading; assessing the reflection, transmission, and absorption properties of candidate armor materials; assessing material properties at high rates of loading; assessing the response of biological materials to shock wave exposure; and providing a means to validate numerical models of the interaction of shock waves with structures. All of these activities have been difficult to pursue in a laboratory setting due in part to lack of appropriate means to produce a realistic blast loading profile.
NASA Astrophysics Data System (ADS)
Yao, Shunchun; Xu, Jialong; Dong, Xuan; Zhang, Bo; Zheng, Jianping; Lu, Jidong
2015-08-01
The on-line measurement of coal is extremely useful for emission control and combustion process optimization in coal-fired plant. Laser-induced breakdown spectroscopy was employed to directly analyze coal particle flow. A set of tapered tubes were proposed for beam-focusing the coal particle flow to different diameters. For optimizing the measurement of coal particle flow, the characteristics of laser-induced plasma, including optical breakdown, the relative standard deviation of repeated measurement, partial breakdown spectra ratio and line intensity, were carefully analyzed. The comparison of the plasma characteristics among coal particle flow with different diameters showed that air breakdown and the random change in plasma position relative to the collection optics could significantly influence on the line intensity and the reproducibility of measurement. It is demonstrated that the tapered tube with a diameter of 5.5 mm was particularly useful to enrich the coal particles in laser focus spot as well as to reduce the influence of air breakdown and random changes of plasma in the experiment.
Development of miniature, high frequency pulse tube cryocoolers
NASA Astrophysics Data System (ADS)
Radebaugh, Ray; Garaway, Isaac; Veprik, Alexander M.
2010-04-01
Because acoustic power density is proportional to frequency, the size of pulse tube cryocoolers for a given refrigeration power can be reduced by operating them at higher frequencies. A frequency of about 60 Hz had been considered the maximum frequency that could be used while maintaining high efficiency. Recently, we have shown through modeling that by decreasing the volume and hydraulic diameter of the regenerator and increasing the average pressure, it is possible to maintain high efficiency even for frequencies of several hundred hertz. Subsequent experimental results have demonstrated high efficiencies for frequencies of 100 to 140 Hz. The very high power density achieved at higher pressures and higher frequencies leads to very short cooldown times and very compact devices. The use of even higher frequencies requires the development of special compressors designed for such conditions and the development of regenerator matrices with hydraulic diameters less than about 30 Μm. To demonstrate the advantages of higher frequency operation, we discuss here the development of a miniature pulse tube cryocooler designed to operate at 80 K with a frequency of 150 Hz and an average pressure of 5.0 MPa. The regenerator diameter and length are 4.4 mm and 27 mm, respectively. The lowest temperature achieved to date has been 97 K, but a net refrigeration power of 530 mW was achieved at 120 K. Acoustic mismatches with existing compressors significantly limit the efficiency, but necessary modifications to improve the acoustic impedance match between the compressor and the cold head are discussed briefly.
NASA Astrophysics Data System (ADS)
Kado, B.; Mohammad, S.; Lee, Y. H.; Shek, P. N.; Kadir, M. A. A.
2018-04-01
Standard fire test was carried out on 3 hollow steel tube and 6 foamed concrete filled steel tube columns. Temperature distribution on the columns was investigated. 1500 kg/m3 and 1800 kg/m3 foamed concrete density at 15%, 20% and 25% load level are the parameters considered. The columns investigated were 2400 mm long, 139.7 mm outer diameter and 6 mm steel tube thickness. The result shows that foamed concrete filled steel tube columns has the highest fire resistance of 43 minutes at 15% load level and low critical temperature of 671 ºC at 25% load level using 1500 kg/m3 foamed concrete density. Fire resistance of foamed concrete filled column increases with lower foamed concrete strength. Foamed concrete can be used to provide more fire resistance to hollow steel column or to replace normal weight concrete in concrete filled columns. Since filling hollow steel with foamed concrete produce column with high fire resistance than unfilled hollow steel column. Therefore normal weight concrete can be substituted with foamed concrete in concrete filled column, it will reduces the self-weight of the structure because of its light weight at the same time providing the desired fire resistance.
NASA Astrophysics Data System (ADS)
Hatsukade, Yoshimi; Kosugi, Akifumi; Mori, Kazuaki; Tanaka, Saburo
2004-11-01
An eddy-current-based nondestructive inspection (NDI) system using superconducting quantum interference device (SQUID) cooled using a coaxial pulse tube cryocooler was constructed for the inspection of microflaws on copper tubes employing a high-Tc SQUID gradiometer and a Helmholtz-like coil inducer. The detection of artificial flaws several tens of μm in depth on copper tubes 6.35 mm in outer diameter and 0.825 mm in thickness was demonstrated using the SQUID-NDI system. With an excitation field of 1.6 μT at 5 kHz, a 30-μm-depth flaw was successfully detected by the system at an SN ratio of at least 20. The magnetic signal amplitude due to the flaw was proportional to both excitation frequency and the square of flaw depth. With consideration of the system’s sensitivity, the results indicate that sub-10-μm-depth flaws are detectable by the SQUID-NDI system.
NASA Astrophysics Data System (ADS)
Blaszczuk, Artur; Nowak, Wojciech
2016-10-01
In the present work, the heat transfer study focuses on assessment of the impact of bed temperature on the local heat transfer characteristic between a fluidized bed and vertical rifled tubes (38mm-O.D.) in a commercial circulating fluidized bed (CFB) boiler. Heat transfer behavior in a 1296t/h supercritical CFB furnace has been analyzed for Geldart B particle with Sauter mean diameter of 0.219 and 0.246mm. The heat transfer experiments were conducted for the active heat transfer surface in the form of membrane tube with a longitudinal fin at the tube crest under the normal operating conditions of CFB boiler. A heat transfer analysis of CFB boiler with detailed consideration of the bed-to-wall heat transfer coefficient and the contribution of heat transfer mechanisms inside furnace chamber were investigated using mechanistic heat transfer model based on cluster renewal approach. The predicted values of heat transfer coefficient are compared with empirical correlation for CFB units in large-scale.
A parametric study of the copper chloride laser
NASA Technical Reports Server (NTRS)
Nerheim, N. M.
1977-01-01
A parametric study of the double-pulsed copper chloride laser is reported. The effects of a wide range of variables on the laser energy density and on three characteristic time intervals (the minimum, maximum, and optimum delay time) between the two electrical-discharge pulses were studied. The geometric variables investigated included a tube diameter of 2.3 to 40 mm and a tube length of 3 to 60 cm. Three buffer gases, helium, neon, and argon, were studied over the pressure range 0.5-50 torr, and the tube temperature was varied from 270 to 500 C. The energy density and voltage of both the dissociation and pumping pulse were varied independently from less than 1 mJ/cu cm at 8.5 kV to over 500 mJ/cu cm at 20 kV. The optimum conditions for maximum laser energy density were found to be with 20 torr neon in a 10-mm by 30-cm tube at 400 C. The maximum energy density obtained was 22 microjoules/cu cm.
Experimental analysis of refrigerants flow boiling inside small sized microfin tubes
NASA Astrophysics Data System (ADS)
Diani, Andrea; Rossetto, Luisa
2017-07-01
The refrigerant charge reduction is one of the most challenging issues that the scientific community has to cope to reduce the anthropic global warming. Recently, mini microfin tubes have been matter of research, since they can reach better thermal performance in small domains, leading to a further refrigerant charge reduction. This paper presents experimental results about R134a flow boiling inside a microfin tube having an internal diameter at the fin tip of 2.4 mm. The mass flux was varied between 375 and 940 kg m-2 s-1, heat flux from 10 to 50 kW m-2, vapor quality from 0.10 to 0.99. The saturation temperature at the inlet of the test section was kept constant and equal to 30 °C. R134a thermal and fluid dynamic performances are presented and compared against those obtained with R1234ze(E) and R1234yf and against values obtained during R134a flow boiling inside a 3.4 mm ID microfin tube.
Martinell, Jordi; Kowalewski, Michał; Domènech, Rosa
2012-01-01
We report quantitative analyses of drilling predation on the free-living, tube-dwelling serpulid polychaete Ditrupa arietina from the Cope Cabo marine succession (Pliocene, Spain). Tubes of D. arietina are abundant in the sampled units: 9 bulk samples from 5 horizons yielded ∼5925 specimens of D. arietina. Except for fragmentation, tubes were well preserved. Complete specimens ranged from 3.1 to 13.4 mm in length and displayed allometric growth patterns, with larger specimens being relatively slimmer. Drilled Ditrupa tubes were observed in all samples. Drillholes, identified as Oichnus paraboloides, were characterized by circular to elliptical outline (drillhole eccentricity increased with its diameter), parabolic vertical profile, outer diameter larger than inner diameter, penetration of one tube wall only, narrow range of drill-hole sizes, and non-random (anterior) distribution of drillholes. A total of 233 drilled specimens were identified, with drilling frequencies varying across horizons from 2.7% to 21% (3.9% for pooled data). Many tube fragments were broken across a drillhole suggesting that the reported frequencies are conservative and that biologically-facilitated (drill-hole induced) fragmentation hampers fossil preservation of complete serpulid tubes. No failed or repaired holes were observed. Multiple complete drillholes were present (3.9%). Drilled specimens were significantly smaller than undrilled specimens and tube length and drill-hole diameter were weakly correlated. The results suggest that drillholes were produced by a size-selective, site-stereotypic predatory organism of unknown affinity. The qualitative and quantitative patterns reported here are mostly consistent with previous reports on recent and fossil Ditrupa and reveal parallels with drilling patterns documented for scaphopod mollusks, a group that is ecologically and morphologically similar to Ditrupa. Consistent with previous studies, the results suggest that free-dwelling serpulid polychaetes are preyed upon by drilling predators and may provide a viable source of data on biotic interactions in the fossil record. PMID:22496828
Mid-Infrared Optoelectronics: Materials and Devices. MIOMD-XII
2014-10-01
current. An enhancement of the QEPAS signal can be achieved when two metallic tubes acting as a micro‐ resonator (mR) are added to the QTF sensor ...spectrophone configuration using a 5.8 mm long micro‐ resonator with an inner diameter of 0.80 mm [3]. In order to test and validate the developed QEPAS sensor ...materials, photodetectors, sensors and applications have been discussed in other sessions. The papers were submitted by researchers representing 107
[Difficult reintubation during a Fantoni's tracheostomy resolved using a laryngeal mask].
Ould-Ahmed, M; Mas, B; Paris, A; Caroff, P; Segalen, F
2001-04-01
We report the failure of a reintubation under direct laryngoscopy, during a percutaneous tracheostomy by Fantoni method. After the accidental per-procedural extubation and in front of an unpredicted difficult conventional endotracheal intubation, a laryngeal mask was used as an airway intubator conduit for the blind passage of the set's ventilation tube. This ventilation tube is a 40 cm long, 4 mm internal diameter special catheter with low pressure cuff, included into the TLT kit. The end of the procedure was uneventful.
NASA Astrophysics Data System (ADS)
Demir, Ali Gökhan; Previtali, Barbara; Colombo, Daniele; Ge, Qiang; Vedani, Maurizio; Petrini, Lorenza; Wu, Wei; Biffi, Carlo Alberto
2012-02-01
Magnesium alloys constitute an attractive solution for cardiovascular stent applications due to their intrinsic properties of biocompatibility and relatively low corrosion resistance in human-body fluids, which results in as a less intrusive treatment. Laser micromachining is the conventional process used to cut the stent mesh, which plays the key role for the accurate reproduction of the mesh design and the surface quality of the produced stent that are important factors in ensuring the mechanical and corrosion resistance properties of such a kind of devices. Traditionally continuous or pulsed laser systems working in microsecond pulse regime are employed for stent manufacturing. Pulsed fiber lasers on the other hand, are a relatively new solution which could balance productivity and quality aspects with shorter ns pulse durations and pulse energies in the order of mJ. This work reports the study of laser micromachining and of AZ31 magnesium alloy for the manufacturing of cardiovascular stents with a novel mesh design. A pulsed active fiber laser system operating in nanosecond pulse regime was employed for the micromachining. Laser parameters were studied for tubular cutting on a common stent material, AISI 316L tubes with 2 mm in diameter and 0.2 mm in thickness and on AZ31 tubes with 2.5 mm in diameter and 0.2 in thickness. In both cases process parameters conditions were examined for reactive and inert gas cutting solutions and the final stent quality is compared.
Low friction and high strength of 316L stainless steel tubing for biomedical applications.
Amanov, Auezhan; Lee, Soo-Wohn; Pyun, Young-Sik
2017-02-01
We propose herein a nondestructive surface modification technique called ultrasonic nanocrystalline surface modification (UNSM) to increase the strength and to improve the tribological performance of 316L stainless steel (SS) tubing. Nanocrystallization along nearly the complete tube thickness of 200μm was achieved by UNSM technique that was confirmed by electron backscatter diffraction (EBSD). Nano-hardness of the untreated and UNSM-treated specimens was measured using a nanoindentation. Results revealed that a substantial increase in hardness was obtained for the UNSM-treated specimen that may be attributed to the nanocrystallization and refined grains. Stress-strain behavior of the untreated and UNSM-treated specimens was assessed by a 3-point bending test. It was found that the UNSM-treated specimen exhibited a much higher strength than that of the untreated specimen. In addition, the tribological behavior of the untreated and UNSM-treated specimens with an outer diameter (OD) of 1.6mm and an inner diameter (ID) of 1.2mm was investigated using a cylinder-on-cylinder (crossed tubes of equal radius) tribo-tester against itself under dry conditions at ambient temperature. The friction coefficient and wear resistance of the UNSM-treated specimen were remarkably improved compared to that of the untreated specimen. The significant increase in hardness after UNSM treatment is responsible for the improved friction coefficient and wear resistance of the tubing. Thus, the UNSM technique was found to be beneficial to improving the mechanical and tribological properties of 316L SS tubing for various potential biomedical applications, in particular for coronary artery stents. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Furushima, Tsuyoshi; Sakai, Takashi; Manabe, Ken-ichi
2004-06-01
Dieless drawing is a unique deformation process without conventional dies, which can achieve a great reduction of wire and tube metals in single pass by means of local heating and cooling approach. In this study, for microtube forming, the dieless drawing process applying superplastic behavior was analyzed by finite element method (FEM) in order to clarify the effect of dieless tube drawing conditions such as tensile speed, moving speed of heating and cooling system, and material properties on deformation behavior of the tube. In the calculation, the material properties were dealt in a special subroutine, whose constitutive equation was defined as σ = Kɛnɛ˙m, and was linked to the solver. A coupled thermo-mechanical analysis was performed for the dieless tube drawing using the FEM. In the thermal analysis of dieless tube drawing, heat transfer was introduced to calculate the heat flux between heating coil and tube surface, and heat conduction in a tube. The influence of dieless tube drawing conditions on deformation behavior was clarified. As a result, for the strain rate sensitive material, the maximum reduction of area and the minimum outer diameter in single pass attain to 90.9% and 2.56mm, respectively. From the result, it is concluded that the dieless tube drawing is essential to produce an extrafine microtube by reason of keeping cylindrical tube diameter ratio constant with extremely high reduction.
COTS MEMS Flow-Measurement Probes
NASA Technical Reports Server (NTRS)
Redding, Chip; Smith, Floyd A.; Blank, Greg; Cruzan, Charles
2004-01-01
As an alternative to conventional tubing instrumentation for measuring airflow, designers and technicians at Glenn Research Center have been fabricating packaging components and assembling a set of unique probes that contain commercial off-the-shelf (COTS) microelectromechanical systems (MEMS) sensor chips. MEMS sensor chips offer some compelling advantages over standard macroscopic measurement devices. MEMS sensor technology has matured through mass production and use in the automotive and aircraft industries. At present, MEMS are the devices of choice for sensors in such applications as tire-pressure monitors, altimeters, pneumatic controls, cable leak detectors, and consumer appliances. Compactness, minimality of power demand, rugged construction, and moderate cost all contribute to making MEMS sensors attractive for instrumentation for future research. Conventional macroscopic flow-measurement instrumentation includes tubes buried beneath the aerodynamic surfaces of wind-tunnel models or in wind-tunnel walls. Pressure is introduced at the opening of each such tube. The pressure must then travel along the tube before reaching a transducer that generates an electronic signal. The lengths of such tubes typically range from 20 ft (approx.= 6 m) to hundreds of feet (of the order of 100 m). The propagation of pressure signals in the tubes damps the signals considerably and makes it necessary to delay measurements until after test rigs have reached steady-state operation. In contrast, a MEMS pressure sensor that generates electronic output can take readings continuously under dynamic conditions in nearly real time. In order to use stainless-steel tubing for pressure measurements, it is necessary to clean many tubes, cut them to length, carefully install them, delicately deburr them, and splice them. A cluster of a few hundred 1/16-in.- (approx.=1.6-mm-) diameter tubes (such clusters are common in research testing facilities) can be several inches (of the order of 10 cm) in diameter and could weigh enough that two technicians are needed to handle it. Replacing hard tubing with electronic chips can eliminate much of the bulk. Each sensor would fit on the tip of a 1/16-in. tube with room to spare. The Lucas NovaSensor P592 piezoresistive silicon pressure sensor was chosen for this project because of its cost, availability, and tolerance to extreme ambient conditions. The sensor chip is 1 mm square by 0.6 mm thick (about 0.039 by 0.039 by 0.024 in.) and includes 0.12-mm (approx.=0.005-in.) wire connection tabs. The figure shows a flow-angularity probe that was built by use of three such MEMS chips. It is planned to demonstrate this MEMS probe as an alternative to a standard tube-type "Cobra" probe now used routinely in wind tunnels and aeronautical hardware. This MEMS probe could be translated across a flow field by use of a suitable actuator, so that its accuracy and the shortness of its response time could be exploited to obtain precise dynamic measurements of a sort that cannot be made by use of conventional tubing-based instrumentation.
Catalyzed Ignition of Bipropellants in Microtubes
NASA Technical Reports Server (NTRS)
Schneider, Steven J.; Boyarko, George A.; Sung, Chih-Jen
2003-01-01
This paper addresses the need to understand the physics and chemistry involved in propellant combustion processes in micro-scale combustors for propulsion systems on micro-spacecraft. These spacecraft are planned to have a mass less than 50 kilograms with attitude control estimated to be in the 10 milli-Newton thrust class. These combustors are anticipated to be manufactured using Micro Electrical Mechanical Systems (MEMS) technology and are expected to have diameters approaching the quenching diameter of the propellants. Combustors of this size are expected to benefit significantly from surface catalysis processes. Miniature flame tube apparatus is chosen for this study because microtubes can be easily fabricated from known catalyst materials and their simplicity in geometry can be used in fundamental simulations to more carefully characterize the measured heat transfer and pressure losses for validation purposes. Experimentally, we investigate the role of catalytically active surfaces within 0.4 and 0.8 mm internal diameter micro-tubes, with special emphases on ignition and extinction processes in fuel rich gaseous hydrogen and gaseous oxygen. Flame thickness and reaction zone thickness calculations predict that the diameters of our test apparatus are below the quenching diameter of the propellants in sub-atmospheric tests. Temperature and pressure rises in resistively heated platinum and palladium micro-tubes are used as an indication of exothermic reactions. Specific data on mass flow versus preheat temperature required to achieve ignition are presented.
NASA Astrophysics Data System (ADS)
D'Amours, Guillaume; Rahem, Ahmed; Williams, Bruce; Worswick, Michael; Mayer, Robert
2007-05-01
The automotive industry, with an increasing demand to reduce vehicle weight through the adoption of lightweight materials, requires a search of efficient methods that suit these materials. One attractive concept is to use hydroforming of aluminium tubes. By using FE simulations, the process can be optimized to reduce the risk for failure while maintaining energy absorption and component integrity under crash conditions. It is important to capture the level of residual ductility after forming to allow proper design for crashworthiness. This paper presents numerical and experimental studies that have been carried out for high pressure hydroforming operations to study the influence of the tube corner radius, end feeding, material thinning, and work hardening in 76.2 mm diameter, 3 mm wall thickness AA5754 aluminium alloy tube. End feeding was used to increase the formability of the tubes. The influence of the end feed displacement versus tube forming pressure schedule was studied to optimize the forming process operation to reduce thinning. Validation of the numerical simulations was performed by comparison of the predicted strain distributions and thinning, with measured quantities. The effect of element formulation (thin shell versus solid elements) was also considered in the models.
Dryout occurrence in a helically coiled steam generator for nuclear power application
NASA Astrophysics Data System (ADS)
Santini, L.; Cioncolini, A.; Lombardi, C.; Ricotti, M.
2014-03-01
Dryout phenomena have been experimentally investigated in a helically coiled steam generator tube. The experiences carried out in the present work are part of a wide experimental program devoted to the study of a GEN III+ innovative nuclear power plant [1].The experimental facility consists in an electrically heated AISI 316L stainless steel coiled tube. The tube is 32 meters long, 12.53 mm of inner diameter, with a coil diameter of 1m and a pitch of 0.79 m, resulting in a total height of the steam generator of 8 meters. The thermo-hydraulics conditions for dryout investigations covered a spectrum of mass fluxes between 199 and 810 kg/m2s, the pressures ranges from 10.7 to 60.7 bar, heat fluxes between 43.6 to 209.3 kW/m2.Very high first qualities dryout, between 0.72 and 0.92, were found in the range of explored conditions, comparison of our results with literature available correlations shows the difficulty in predicting high qualities dryout in helical coils., immediately following the heading. The text should be set to 1.15 line spacing. The abstract should be centred across the page, indented 15 mm from the left and right page margins and justified. It should not normally exceed 200 words.
Demonstrations of Gravity-Independent Mobility and Drilling on Natural Rock using Microspines
NASA Technical Reports Server (NTRS)
Parness, Aaron; Frost, Matthew; King, Jonathan P.; Thatte, Nitish
2012-01-01
The video presents microspine-based anchors be ing developed for gripping rocks on the surfaces of comets and asteroids, or for use on cliff faces and lava tubes on Mars. Two types of anchor prototypes are shown on supporting forces in all directions away from the rock; >160 N tangent, >150 N at 45?, and >180 N normal to the surface of the rock. A compliant robotic ankle with two active degrees of freedom interfaces these anchors to the Lemur IIB robot for future climbing trials. Finally, a rotary percussive drill is shown coring into rock regardless of gravitational orientation. As a harder- than-zero-g proof of concept, inverted drilling was performed creating 20mm diameter boreholes 83 mm deep in vesicular basalt samples while retaining 12 mm diameter rock cores in 3-6 pieces.
The Bulging Behavior of Thick-Walled 6063 Aluminum Alloy Tubes Under Double-Sided Pressures
NASA Astrophysics Data System (ADS)
Cui, Xiao-Lei; Wang, Xiao-Song; Yuan, Shi-Jian
2015-05-01
To make further exploration on the deformation behavior of tube under double-sided pressures, the thick-walled 6063 aluminum alloy tubes with an outer diameter of 65 mm and an average thickness of 7.86 mm have been used to be bulged under the combined action of internal and external pressures. In the experiment, two ends of the thick-walled tubes were fixed using the tooth and groove match. Three levels of external pressure (0 MPa, 40 MPa, and 80 MPa), in conjunction with the internal pressure, were applied on the tube outside and inside simultaneously. The effect of external pressure on the bulging behavior of the thick-walled tubes, such as the limiting expansion ratio, the bulging zone profile, and the thickness distribution, has been investigated. It is shown that the limiting expansion ratio, the bulging zone profile, and the thickness distribution in the homogeneous bulging area are all insensitive to the external pressure. However, the external pressure can make the thick-walled tube achieve a thinner wall at the fracture area. It reveals that the external pressure can only improve the fracture limit of the thick-walled 6063 tubes, but it has very little effect on their homogeneous bulging behavior. It might be because the external pressure can only increase the magnitude of the hydrostatic pressure for the tube but has no effect on the Lode parameter.
Applications of the ram accelerator to hypervelocity aerothermodynamic testing
NASA Technical Reports Server (NTRS)
Bruckner, A. P.; Knowlen, C.; Hertzberg, A.
1992-01-01
A ram accelerator used as a hypervelocity launcher for large-scale aeroballistic range applications in hypersonics and aerodynamics research is presented. It is an in-bore ramjet device in which a projectile shaped like the centerbody of a supersonic ramjet is propelled down a stationary tube filled with a tailored combustible gas mixture. Ram accelerator operation has been demonstrated at 39 mm and 90 mm bores, supporting the proposition that this launcher concept can be scaled up to very large bore diameters of the order of 30-60 cm. It is concluded that high quality data obtained from the tube wall and projectile during the aceleration process itself are very useful for understanding aerothermodynamics of hypersonic flow in general, and for providing important CFD validation benchmarks.
Cyclic fatigue of ProTaper instruments.
Lopes, Hélio Pereira; Moreira, Edson Jorge Lima; Elias, Carlos Nelson; de Almeida, Renata Andriola; Neves, Mônica Schultz
2007-01-01
The present work evaluated the influence of the curved segment length of artificial root canals (the arc) and the number of cycles necessary to fracture engine-driven nickel-titanium endodontic instruments. ProTaper F3 25-mm files at 250 rpm were used in two artificial canals. The artificial canals were made of stainless steel with an inner diameter of 1.04 mm, a total length of 20 mm, and arc on the ends with a radius of curvature of 6 mm. The arc length of the first tube measured 9.4 mm, and the straight part measured 10.6 mm. The second tube was 14.1 mm long, and the straight part measured 5.9 mm. We determined the fracture surface distances and the number of cycles necessary to induce fatigue fracture in the ProTaper F3 instruments. The fracture surfaces and the helical shaft of the instruments were investigated using a scanning electron microscope. The results indicated that the required number of cycles to cause a fracture was influenced by the canal arc length, the morphology of the fractured surface presented ductile characteristics, and plastic deformation in the helical shaft of the fractured instruments did not occur.
NASA Technical Reports Server (NTRS)
Sparks, S. D.
1973-01-01
The Varian cup and slat dynode chain was modified to have a flat cathode. These modifications were incorporated in an all-electrostatic photomultiplier tube having a rise time of 0.25 n sec. The tube delivered under the contract had a flat S-20 opaque cathode with a useful diameter of 5 mm. The design of the tube is such that a III to V cathode support is mounted in place of the existing cathode substrate. This cathode support is designed to accept a transferred III to V cathode and maintain the cathode surface in the same position as the S-20 photocathode.
Wistbacka, Greta; Andrade, Pedro Amarante; Simberg, Susanna; Hammarberg, Britta; Södersten, Maria; Švec, Jan G; Granqvist, Svante
2018-01-01
Resonance tube phonation with tube end in water is a voice therapy method in which the patient phonates through a glass tube, keeping the free end of the tube submerged in water, creating bubbles. The purpose of this experimental study was to determine flow-pressure relationship, flow thresholds between bubble types, and bubble frequency as a function of flow and back volume. A flow-driven vocal tract simulator was used for recording the back pressure produced by resonance tubes with inner diameters of 8 and 9 mm submerged at water depths of 0-7 cm. Visual inspection of bubble types through video recording was also performed. The static back pressure was largely determined by the water depth. The narrower tube provided a slightly higher back pressure for a given flow and depth. The amplitude of the pressure oscillations increased with flow and depth. Depending on flow, the bubbles were emitted from the tube in three distinct types with increasing flow: one by one, pairwise, and in a chaotic manner. The bubble frequency was slightly higher for the narrower tube. An increase in back volume led to a decrease in bubble frequency. This study provides data on the physical properties of resonance tube phonation with the tube end in water. This information will be useful in future research when looking into the possible effects of this type of voice training. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Hindasageri, V; Vedula, R P; Prabhu, S V
2013-02-01
Temperature measurement by thermocouples is prone to errors due to conduction and radiation losses and therefore has to be corrected for precise measurement. The temperature dependent emissivity of the thermocouple wires is measured by the use of thermal infrared camera. The measured emissivities are found to be 20%-40% lower than the theoretical values predicted from theory of electromagnetism. A transient technique is employed for finding the heat transfer coefficients for the lead wire and the bead of the thermocouple. This method does not require the data of thermal properties and velocity of the burnt gases. The heat transfer coefficients obtained from the present method have an average deviation of 20% from the available heat transfer correlations in literature for non-reacting convective flow over cylinders and spheres. The parametric study of thermocouple error using the numerical code confirmed the existence of a minimum wire length beyond which the conduction loss is a constant minimal. Temperature of premixed methane-air flames stabilised on 16 mm diameter tube burner is measured by three B-type thermocouples of wire diameters: 0.15 mm, 0.30 mm, and 0.60 mm. The measurements are made at three distances from the burner tip (thermocouple tip to burner tip/burner diameter = 2, 4, and 6) at an equivalence ratio of 1 for the tube Reynolds number varying from 1000 to 2200. These measured flame temperatures are corrected by the present numerical procedure, the multi-element method, and the extrapolation method. The flame temperatures estimated by the two-element method and extrapolation method deviate from numerical results within 2.5% and 4%, respectively.
NASA Astrophysics Data System (ADS)
Hindasageri, V.; Vedula, R. P.; Prabhu, S. V.
2013-02-01
Temperature measurement by thermocouples is prone to errors due to conduction and radiation losses and therefore has to be corrected for precise measurement. The temperature dependent emissivity of the thermocouple wires is measured by the use of thermal infrared camera. The measured emissivities are found to be 20%-40% lower than the theoretical values predicted from theory of electromagnetism. A transient technique is employed for finding the heat transfer coefficients for the lead wire and the bead of the thermocouple. This method does not require the data of thermal properties and velocity of the burnt gases. The heat transfer coefficients obtained from the present method have an average deviation of 20% from the available heat transfer correlations in literature for non-reacting convective flow over cylinders and spheres. The parametric study of thermocouple error using the numerical code confirmed the existence of a minimum wire length beyond which the conduction loss is a constant minimal. Temperature of premixed methane-air flames stabilised on 16 mm diameter tube burner is measured by three B-type thermocouples of wire diameters: 0.15 mm, 0.30 mm, and 0.60 mm. The measurements are made at three distances from the burner tip (thermocouple tip to burner tip/burner diameter = 2, 4, and 6) at an equivalence ratio of 1 for the tube Reynolds number varying from 1000 to 2200. These measured flame temperatures are corrected by the present numerical procedure, the multi-element method, and the extrapolation method. The flame temperatures estimated by the two-element method and extrapolation method deviate from numerical results within 2.5% and 4%, respectively.
Morphology and morphometry of the reproductive system of female Saguinus midas (Linnaeus, 1758).
Monteiro, Nathaly Cristine Da Silva; De Lima, Ana Rita; De Carvalho, Ana Flávia; De Carvalho Garcia, Rafael; Therrier, Joanne; Souza, Ana Carla Barros; Pereira, Luiza Correia; Branco, Erika
2012-06-01
In this article, the reproductive system's morphology of three young animals of the species Saguinus midas, from the bauxite mine in Paragominas, is described. The specimens were fixed and preserved in a solution of 10% aqueous formaldehyde, followed by dissection, measurement of the genital organs (uterus, vagina, ovaries, and uterine tubes), and histological processing. The vulva is delimited by the labia, with a clitoris. It is lined by keratinized stratified squamous epithelium with sebaceous glands of holocrine secretion. The vagina is an elongated tube with an average length of 26 mm and diameter of 1 mm, presenting a non-keratinized squamous epithelium, disposed between the vestibule of the vagina and cervix, the latter being relatively short. The uterus is simple, has globular shape and is located in the caudal portion of the abdominal cavity, with an average length of 14 mm and average width of 7 mm. It is formed by vascular and serous layers of muscles, and undergoes a bifurcation to form two structures on the bottom of blind sac. The uterine tubes are long and convoluted with an average length of 35 mm (right) and 36 mm (left), consisting of loose connective tissue and muscle layer lined by simple ciliated columnar epithelium. The ovaries are large and ellipsoid with smooth surface. Histologically, one animal showed ovulation fosse. Copyright © 2011 Wiley Periodicals, Inc.
Rutala, W A; Gergen, M F; Weber, D J
1998-08-01
This study was undertaken to evaluate the efficacy of 4 new low-temperature sterilization technologies: ethylene oxide with hydrochlorofluorocarbons, a liquid peracetic acid immersion system (Steris System 1 Processor), and 2 plasma sterilization processes that use vaporized hydrogen peroxide (Sterrad 100 and the Sterrad 100S). The Sterrad 100S system potentially improves sterilizer efficacy by using 2 cycles of a diffusion stage and a plasma stage per sterilization cycle. Flat stainless steel carriers were inoculated with approximately 10(6) Bacillus stearothermophilus spores. These carriers were aseptically placed in the middle of 40 cm long stainless steel lumens (hollow tubes). Two types of lumen were used:(1) a lumen test unit with a removable 5 cm center piece (1.2 cm diameter) of stainless steel sealed to the narrower steel tubing by hard rubber septums and (2) a straight lumen. Three different diameters of the lumen test unit (1, 2, and 3 mm) and a single diameter of the straight lumen (3 mm) were studied. At least 40 replicates were performed for each type of lumen and sterilization method. After inoculation, the test unit was evaluated in 1 of the low-temperature sterilization technologies. After sterilization, the carriers were cultured in trypticase soy broth for 14 days at 55 degrees C and assessed for growth of B stearothermophilus spores. Our results demonstrated that ethylene oxide with hydrochlorofluorocarbons, the Sterrad 100s, and the Sterrad 100S half cycle were highly effective in killing approximately 10(6) B stearothermophilus spores present in the center of narrow-lumen stainless steel tubes. As the lumen diameter decreased with the lumen test unit, the Sterrad 100 demonstrated reduced ability to kill B stearothermophilus spores present on the carrier. At the smallest diameter tested (1 mm), the Sterrad 100 system failed 74% of the time. The Steris System 1 was not effective in completely eliminating the 10(6) inoculum under test conditions. The Sterrad 100S was significantly superior to the Sterrad 100 system and equivalent to ethylene oxide with hydrochlorofluorocarbons. Introduction of this new Sterrad 100S system should improve the margin of safety and reduce processing costs by its use of a shorter cycle time. The Steris System 1 is limited by diffusion of the chemical sterilant into the interior of the lumen test unit.
NASA Astrophysics Data System (ADS)
Nakamura, Katsumasa; Sasaki, Tomonari; Ohga, Saiji; Yoshitake, Tadamasa; Terashima, Kotaro; Asai, Kaori; Matsumoto, Keiji; Shinoto, Makoto; Shioyama, Yoshiyuki; Nishie, Akihoro; Honda, Hiroshi
2014-11-01
There are few effective methods to detect or prevent the extravasation of injected materials such as chemotherapeutic agents and radiographic contrast materials. To investigate whether a thermographic camera could visualize the superficial vein and extravasation using the temperature gradient produced by the injected materials, an infrared thermographic camera with a high resolution of 0.04 °C was used. At the room temperature of 26 °C, thermal images and the time course of the temperature changes of a paraffin phantom embedded with rubber tubes (diameter 3.2 mm, wall thickness 0.8 mm) were evaluated after the tubes were filled with water at 15 °C or 25 °C. The rubber tubes were embedded at depths of 0 mm, 1.5 mm, and 3.0 mm from the surface of the phantom. Temperature changes were visualized in the areas of the phantom where the tubes were embedded. In general, changes were more clearly detected when greater temperature differences between the phantom and the water and shallower tube locations were employed. The temperature changes of the surface of a volunteer's arm were also examined after a bolus injection of physiological saline into the dorsal hand vein or the subcutaneous space. The injection of 5 ml room-temperature (26 °C) saline into the dorsal hand vein enabled the visualization of the vein. When 3 ml of room-temperature saline was injected through the vein into the subcutaneous space, extravasation was detected without any visualization of the vein. The subtraction image before and after the injection clearly showed the temperature changes induced by the saline. Thermography may thus be useful as a monitoring system to detect extravasation of the injected materials.
Suzuki, S; Nakamura, S; Sakaguchi, T; Mitsuoka, H; Tsuchiya, Y; Kojima, Y; Konno, H; Baba, S
1998-11-01
Animal models of total hepatic ischemia (THI) and reperfusion injury are restricted by concomitant splanchnic congestion. This study was performed to determine the requirement suitable for an extracorporeal portosystemic shunt (PSS) to maintain the intestinal integrity in a rat model of THI. Using a polyethylene tube (0.86 or 1 mm i.d.), PSS was placed between the mesenteric and jugular veins. Comparison was done between THI models with or without PSS and a partial ischemia model with hepatectomy of the nonischemic lobes. Well-tolerated hepatic ischemic period, portal pressure after 10 min of hepatic ischemia, portal endotoxin levels at 1 h after reperfusion, histological features of the small bowel just before reperfusion, and local jejunal and ileal blood hemoglobin oxygen saturation index (ISO2) were compared among the models. Animals without PSS poorly tolerated 30 min of THI. Animals receiving THI with PSS or partial hepatic ischemia tolerated a longer ischemic period (60 min) with a significantly higher small bowel ISO2, lower portal pressure and endotoxin levels (P < 0.01), and less histological damage of the small bowel when compared to those receiving THI without PSS. Portal endotoxin levels after THI with PSS using a 1-mm i.d. tube as well as partial hepatic ischemia were significantly lower than those after THI with PSS using a 0.86-mm i.d. tube. THI with PSS using a 1-mm i.d. tube was strikingly similar to partial hepatic ischemia in the pathophysiological profile during hepatic ischemia. PSS with a tube 1 mm or more in inner diameter offers pathophysiological advantages in experiments on THI and reperfusion. Copyright 1998 Academic Press.
NASA Astrophysics Data System (ADS)
Yu, Jianding; Koshikawa, Naokiyo; Arai, Yasutomo; Yoda, Shinichi; Saitou, Hirofumi
2001-11-01
Containerless solidification of BiFeO 3 has been carried out in microgravity with an electrostatic levitation furnace (ELF) on board a sounding rocket (TR-IA). This was the first time the ELF was used in microgravity to study the solidification behavior of oxide insulator material. A spherical BiFeO 3 specimen with a diameter of 5 mm was laser heated and solidified in an oxygen and nitrogen mixture atmosphere. The microstructure resulting from solidification in the ELF was compared with that obtained from solidification in a 10 m drop tube and in crucibles. In the crucible experiments, the segregation of the primary Fe 2O 3 phase could not be suppressed, even if the cooling speed increased to 5000 K/s. However it did suppress in a 0.3 mm diameter droplet solidified in the drop tube experiment. This suggests that containerless processing effectively promoted the undercooling of the BiFeO 3 phase. In the microgravity experiment, although a homogeneous BiFeO 3 phase was not observed in the 5 mm spherical specimen, an anomalous fine cellular microstructure appeared due to high undercooling. In addition, the phase transitions of BiFeO 3 were measured by DTA from room temperature to 1523 K and its liquidus temperature was estimated to be 1423 K.
Compliant electrospun silk fibroin tubes for small vessel bypass grafting.
Marelli, Benedetto; Alessandrino, Antonio; Farè, Silvia; Freddi, Giuliano; Mantovani, Diego; Tanzi, Maria Cristina
2010-10-01
Processing silk fibroin (SF) by electrospinning offers a very attractive opportunity for producing three-dimensional nanofibrillar matrices in tubular form, which may be useful for a biomimetic approach to small calibre vessel regeneration. Bypass grafting of small calibre vessels, with a diameter less than 6mm, is performed mainly using autografts, like the saphenous vein or internal mammary artery. At present no polymeric grafts made of SF are commercially available, mainly due to inadequate properties (low compliance and lack of endothelium cells). The aim of this work was to electrospin SF into tubular structures (Ø=6mm) for small calibre vessel grafting, characterize the morphological, chemico-physical and mechanical properties of the electrospun SF structures and to validate their potential to interact with cells. The morphological properties of electrospun SF nanofibres were investigated by scanning electron microscopy. Chemico-physical analyses revealed an increase in the crystallinity of the structure of SF nanofibres on methanol treatment. Mechanical tests, i.e. compliance and burst pressure measurements, of the electrospun SF tubes showed that the inner pressure to radial deformation ratio was linear for elongation up to 15% and pressure up to 400 mm Hg. The mean compliance value between 80 and 120 mm Hg was higher than the values reported for both Goretex(R) and Dacron(R) grafts and for bovine heterografts, but still slightly lower than those of saphenous and umbilical vein, which nowadays represent the gold standard for the replacement of small calibre arteries. The electrospun tubes resisted up to 575+/-17 mmHg, which is more than four times the upper physiological pressure of 120 mmHg and more than twice the pathological upper pressures (range 180-220 mmHg). The in vitro tests showed a good cytocompatibility of the electrospun SF tubes. Therefore, the electrospun SF tubes developed within this work represent a suitable candidate for small calibre blood vessel replacement. 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Jeličić, Aleksandra; Friedrich, Alwin; Jeremić, Katarina; Siekmeyer, Gerd; Taubert, Andreas
2009-01-01
One of the main issues with the use of nickel titanium alloy (NiTi) implants in cardiovascular implants (stents) is that these devices must be of very high quality in order to avoid subsequent operations due to failing stents. For small stents with diameters below ca. 2 mm, however, stent characterization is not straightforward. One of the main problems is that there are virtually no methods to characterize the interior of the NiTi tubes used for fabrication of these tiny stents. The current paper reports on a robust hybrid actuator for the characterization of NiTi tubes prior to stent fabrication. The method is based on a polymer/hydrogel/magnetic nanoparticle hybrid material and allows for the determination of the inner diameter at virtually all places in the raw NiTi tubes. Knowledge of the inner structure of the raw NiTi tubes is crucial to avoid regions that are not hollow or regions that are likely to fail due to defects inside the raw tube. The actuator enables close contact of a magnetic polymer film with the inner NiTi tube surface. The magnetic signal can be detected from outside and be used for a direct mapping of the tube interior. As a result, it is possible to detect critical regions prior to expensive and slow stent fabrication processes.
The thin-wall tube drift chamber operating in vacuum (prototype)
NASA Astrophysics Data System (ADS)
Alexeev, G. D.; Glonti, L. N.; Kekelidze, V. D.; Malyshev, V. L.; Piskun, A. A.; Potrbenikov, Yu. K.; Rodionov, V. K.; Samsonov, V. A.; Tokmenin, V. V.; Shkarovskiy, S. N.
2013-08-01
The goal of this work was to design drift tubes and a chamber operating in vacuum, and to develop technologies for tubes independent assembly and mounting in the chamber. These design and technology were tested on the prototype. The main features of the chamber are the following: the drift tubes are made of flexible mylar film (wall thickness 36 μm, diameter 9.80 mm, length 2160 mm) using ultrasonic welding along the generatrix; the welding device and methods were developed at JINR. Drift tubes with end plugs, anode wires and spacers were completely assembled outside the chamber. "Self-centering" spacers and bushes were used for precise setting of the anode wires and tubes. The assembled tubes were sealed with O-rings in their seats in the chamber which simplified the chamber assembling. Moreover the tube assembly and the chamber manufacture can be performed independently and in parallel; this sufficiently reduces the total time of chamber manufacture and assembling, its cost and allows tubes to be tested outside the chamber. The technology of independent tube assembling is suitable for a chamber of any shape but a round chamber is preferable for operation in vacuum. Single channel amplifier-discriminator boards which are more stable against cross talks were used for testing the tubes. Independently assembled tubes were mounted into the chamber prototype and its performance characteristic measured under the vacuum conditions. The results showed that both the structure and the tubes themselves normally operate. They are suitable for making a full-scale drift chamber for vacuum.
NASA Astrophysics Data System (ADS)
Shevchenko, A. A.; Dolgoborodov, A. Yu; Kirilenko, V. G.; Brazhnikov, M. A.
2016-11-01
Deflagration-to-detonation transition (DDT) in aluminum-ammonium perchlorate (Al/AP) loose-packed charges (80% porosity) has been studied. The charges were manufactured from preliminary mechanoactivated mixtures. The mixtures placed in steel tubes 10 mm in diameter were ignited by Nichrome wire. It was found that it is possible to distinguish three parts corresponding to different stages of DDT process development. Steady-state detonation velocity reached the level of 2500 m/s at the distance of 90 mm from the ignition point.
Feature extraction in MFL signals of machined defects in steel tubes
NASA Astrophysics Data System (ADS)
Perazzo, R.; Pignotti, A.; Reich, S.; Stickar, P.
2001-04-01
Thirty defects of various shapes were machined on the external and internal wall surfaces of a 177 mm diameter ferromagnetic steel pipe. MFL signals were digitized and recorded at a frequency of 4 Khz. Various magnetizing currents and relative tube-probe velocities of the order of 2m/s were used. The identification of the location of the defect by a principal component/neural network analysis of the signal is shown to be more effective than the standard procedure of classification based on the average signal frequency.
Willford, Wayne A.; Hesselberg, Robert J.; Bergman, Harold L.
1973-01-01
Total mercury in a variety of substances is determined rapidly and precisely by direct sample combustion, collection of released mercury by amalgamation, and photometric measurement of mercury volatilized from the heated amalgam. Up to 0.2 g fish tissue is heated in a stream of O2 (1.2 L/min) for 3.5 min in 1 tube of a 2-tube induction furnace. The released mercury vapor and combustion products are carried by the stream of O2 through a series of traps (6% NaOH scrubber, water condenser, and Mg(CIO4)2 drying tube) and the mercury is collected in a 10 mm diameter column of 24 gauge gold wire (8 g) cut into 3 mm lengths. The resulting amalgam is heated in the second tube of the induction furnace and the volatilized mercury is measured with a mercury vapor meter equipped with a recorder-integrator. Total analysis time is approximately 8 min/sample. The detection limit is less than 0.002 μg and the system is easily converted for use with other biological materials, water, and sediments.
Experimental flow studies in glaucoma drainage device development.
2001-10-01
(I) To examine whether small holes produced by 248 nm excimer laser ablation in a polymer substrate could consistently produce a pressure drop in the desired target range (5-15 mm Hg) at physiological aqueous flow rates for use as an internal flow restrictor in a glaucoma drainage device, and (ii) to investigate whether external leakage could be reduced in comparison with conventional tube and plate glaucoma drainage devices by redesigning the exterior cross sectional shape of the portion contained within the sclerocorneal tunnel. Single holes with target diameters of 10 microm, 15 microm, 20 microm, and 25 microm were drilled using a 248 nm excimer laser in sample discs (n=6 at each diameter) punched from a 75 microm thick polyimide sheet. Sample discs were tested in a flow rig designed to measure the pressure drop across the discs. Using filtered, degassed water at a flow rate of 1.4 microl/min repeated flow measurements were taken (n=6) for each disc. After flow testing, all discs were imaged using a scanning electron microscope and the dimensions of each hole were derived using image analysis software. In the external leakage study, corneoscleral buttons (n=13) were prepared from cadaver pig eyes and mounted on an artificial anterior chamber infused with Tyrode solution. After the pressure had stabilised, standard occluded silicone tube implants were inserted through 23 gauge needle stab incisions at the limbus. These were compared against prototype PMMA implants with a novel shape profile inserted through 1.15 mm width microvitreoretinal (MVR) stab incisions at the limbus. The infusion rate was maintained and a second pressure measurement was taken when the pressure had stabilised. The difference between the first and second pressure measurement was then compared, as an index of external leakage. Ablated tubes were found to have a near perfect circular outline on both the entry and exit side. The observed pressure drops across the ablated sample discs at each target diameter were as follows: 10 microm, mean 25.66 (SD 4.9) mm Hg; 15 microm, 6.7 (1.15); 20 microm, 1.66 (1.07); and 25 microm, <0.1 mm Hg. A strong correlation was observed between observed pressure drops and those predicted by Poiseuille's formula (R(2) =0.996). Target ablations of 15 microm diameter produced tubes that consistently achieved a pressure drop within the desired range (5-15 mm Hg). In the external leakage study, preinsertion pressures (mm Hg; mean (SD)) were 19.00 (4.3) (conventional method) and 20.00 (3.9) (new technique with PMMA prototypes). Post-insertion pressures were significantly reduced (10.40 (7.7); p<0.01) for the conventional technique and were essentially unchanged for the new technique (18.80 (4.9); p>0.1). It was shown that it is possible, in principle, to control the dimensions of a manufactured tubular lumen in a glaucoma drainage device accurately enough to provide consistent protection from hypotony in the early period after glaucoma filtration surgery. By redesigning the external profile of glaucoma drainage device and incision technique, it was also shown that it is possible to eliminate uncontrolled external leakage.
Rewetting of hot vertical rod during jet impingement surface cooling
NASA Astrophysics Data System (ADS)
Agrawal, Chitranjan; Kumar, Ravi; Gupta, Akhilesh; Chatterjee, Barun
2016-06-01
A stainless steel (SS-316) vertical rod of 12 mm diameter at 800 ± 10 °C initial temperature was cooled by normal impinging round water jet. The surface rewetting phenomenon was investigated for a range of jet diameter 2.5-4.8 mm and jet Reynolds number 5000-24,000 using a straight tube type nozzle. The investigation were made from the stagnation point to maximum 40 mm downstream locations, simultaneously for both upside and downside directions. The cooling performance of the vertical rod was evaluated on the basis of rewetting parameters i.e. rewetting temperature, wetting delay, rewetting velocity and the maximum surface heat flux. Two separate Correlations have been proposed for the dimensionless rewetting velocity in terms of rewetting number and the maximum surface heat flux that predicts the experimental data within an error band of ±20 and ±15 % respectively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
D'Amours, Guillaume; Rahem, Ahmed; Williams, Bruce
2007-05-17
The automotive industry, with an increasing demand to reduce vehicle weight through the adoption of lightweight materials, requires a search of efficient methods that suit these materials. One attractive concept is to use hydroforming of aluminium tubes. By using FE simulations, the process can be optimized to reduce the risk for failure while maintaining energy absorption and component integrity under crash conditions. It is important to capture the level of residual ductility after forming to allow proper design for crashworthiness. This paper presents numerical and experimental studies that have been carried out for high pressure hydroforming operations to study themore » influence of the tube corner radius, end feeding, material thinning, and work hardening in 76.2 mm diameter, 3 mm wall thickness AA5754 aluminium alloy tube. End feeding was used to increase the formability of the tubes. The influence of the end feed displacement versus tube forming pressure schedule was studied to optimize the forming process operation to reduce thinning. Validation of the numerical simulations was performed by comparison of the predicted strain distributions and thinning, with measured quantities. The effect of element formulation (thin shell versus solid elements) was also considered in the models.« less
Vaporization inside a mini microfin tube: experimental results and modeling
NASA Astrophysics Data System (ADS)
Diani, A.; Rossetto, L.
2015-11-01
This paper proposes a comparison among the common R134a and the extremely low GWP refrigerant R1234yf during vaporization inside a mini microfin tube. This microfin tube has an internal diameter of 2.4 mm, it has 40 fins, with a fin height of 0.12 mm. Due to the high heat transfer coefficients shown by this tube, this technology can lead to a refrigerant charge reduction. Tests were run in the Heat Transfer in Micro Geometries Lab of the Dipartimento di Ingegneria Industriale of the Università di Padova. Mass velocities range between 375 and 940 kg m-2 s-1, heat fluxes from 10 to 50 kW m-2, vapour qualities from 0.10 to 0.99, at a saturation temperature of 30°C. The comparison among the two fluids is proposed at the same operating conditions, in order to highlight the heat transfer and pressure drop differences among the two refrigerants. In addition, two correlations are proposed to estimate the heat transfer coefficient and frictional pressure drop during refrigerant flow boiling inside mini microfin tubes. These correlations well predict the experimental values, and thus they can be used as a useful tool to design evaporators based on these mini microfin tubes.
Magnetic confinement of weakly ionized plasma with superconducting bulk magnets
NASA Astrophysics Data System (ADS)
Matsuzawa, Hidenori; Ohishi, Kazuya; Ishikawa, Kazuhito; Morita, Tomonori; Yoshikawa, Masaaki; Ikuta, Hiroshi; Mizutani, Uichiro
2003-04-01
This letter describes the application of single-domain superconducting bulk magnets as a plasma confinement. A through-hole was drilled at the center of a Sm123 bulk superconductor of 39 mm diameter and 17 mm thickness. When the sample was field cooled to 77 K, the resulting bulk magnet trapped a magnetic field of ˜0.65 T called a magnetic mirror, in the bore of the hole. The magnet was applied to a weakly ionized neon plasma column. Both the magnet and discharge glass tube were immersed in liquid nitrogen. The spatial distribution in the tube of red fluorescence of the plasma showed that the magnet certainly confined the plasma. These results would provide a clue to applications of the compact magnet of strong magnetic field.
Manohar, Nivedh; Reynoso, Francisco J; Cho, Sang Hyun
2013-08-01
To develop a proof-of-principle L-shell x-ray fluorescence (XRF) imaging system that locates and quantifies sparse concentrations of gold nanoparticles (GNPs) using a benchtop polychromatic x-ray source and a silicon (Si)-PIN diode x-ray detector system. 12-mm-diameter water-filled cylindrical tubes with GNP concentrations of 20, 10, 5, 0.5, 0.05, 0.005, and 0 mg∕cm3 served as calibration phantoms. An imaging phantom was created using the same cylindrical tube but filled with tissue-equivalent gel containing structures mimicking a GNP-loaded blood vessel and approximately 1 cm3 tumor. Phantoms were irradiated by a 3-mm-diameter pencil-beam of 62 kVp x-rays filtered by 1 mm aluminum. Fluorescence∕scatter photons from phantoms were detected at 90° with respect to the beam direction using a Si-PIN detector placed behind a 2.5-mm-diameter lead collimator. The imaging phantom was translated horizontally and vertically in 0.3-mm steps to image a 6 mm×15 mm region of interest (ROI). For each phantom, the net L-shell XRF signal from GNPs was extracted from background, and then corrected for detection efficiency and in-phantom attenuation using a fluorescence-to-scatter normalization algorithm. XRF measurements with calibration phantoms provided a calibration curve showing a linear relationship between corrected XRF signal and GNP mass per imaged voxel. Using the calibration curve, the detection limit (at the 95% confidence level) of the current experimental setup was estimated to be a GNP mass of 0.35 μg per imaged voxel (1.73×10(-2) cm3). A 2D XRF map of the ROI was also successfully generated, reasonably matching the known spatial distribution as well as showing the local variation of GNP concentrations. L-shell XRF imaging can be a highly sensitive tool that has the capability of simultaneously imaging the spatial distribution and determining the local concentration of GNPs presented on the order of parts-per-million level within subcentimeter-sized ex vivo samples and superficial tumors during preclinical animal studies.
Manohar, Nivedh; Reynoso, Francisco J.; Cho, Sang Hyun
2013-01-01
Purpose: To develop a proof-of-principle L-shell x-ray fluorescence (XRF) imaging system that locates and quantifies sparse concentrations of gold nanoparticles (GNPs) using a benchtop polychromatic x-ray source and a silicon (Si)-PIN diode x-ray detector system. Methods: 12-mm-diameter water-filled cylindrical tubes with GNP concentrations of 20, 10, 5, 0.5, 0.05, 0.005, and 0 mg/cm3 served as calibration phantoms. An imaging phantom was created using the same cylindrical tube but filled with tissue-equivalent gel containing structures mimicking a GNP-loaded blood vessel and approximately 1 cm3 tumor. Phantoms were irradiated by a 3-mm-diameter pencil-beam of 62 kVp x-rays filtered by 1 mm aluminum. Fluorescence/scatter photons from phantoms were detected at 90° with respect to the beam direction using a Si-PIN detector placed behind a 2.5-mm-diameter lead collimator. The imaging phantom was translated horizontally and vertically in 0.3-mm steps to image a 6 mm × 15 mm region of interest (ROI). For each phantom, the net L-shell XRF signal from GNPs was extracted from background, and then corrected for detection efficiency and in-phantom attenuation using a fluorescence-to-scatter normalization algorithm. Results: XRF measurements with calibration phantoms provided a calibration curve showing a linear relationship between corrected XRF signal and GNP mass per imaged voxel. Using the calibration curve, the detection limit (at the 95% confidence level) of the current experimental setup was estimated to be a GNP mass of 0.35 μg per imaged voxel (1.73 × 10−2 cm3). A 2D XRF map of the ROI was also successfully generated, reasonably matching the known spatial distribution as well as showing the local variation of GNP concentrations. Conclusions:L-shell XRF imaging can be a highly sensitive tool that has the capability of simultaneously imaging the spatial distribution and determining the local concentration of GNPs presented on the order of parts-per-million level within subcentimeter-sized ex vivo samples and superficial tumors during preclinical animal studies. PMID:23927295
NASA Astrophysics Data System (ADS)
Strickland, Shawn L.; Vandersall, Kevin S.; Dehaven, Martin R.
2017-06-01
The potential for deflagration-to-detonation transition (DDT) in LLM-105 and RX-55-DQ (94/6 LLM-105/Viton) has been investigated as a function of loading density using high confinement tubes. The high confinement arrangement uses a 76 mm outer diameter by 25 mm inner diameter mild steel tube 320 mm in length with 25 mm thick mild steel end caps ignited using a thermite igniter and was loaded with samples of varying densities. None of the experiments showed a transition to detonation over the entire length with non-violent burning or extinguishing of the burning observed. The hand packed RX-55-DQ molding powder or neat LLM-105 ( 1.1 g/cm3) burned nearly completely and vented non-violently by deforming or splitting the end caps. The RX-55-DQ was tested at higher densities with 1.35 g/cm3 resulting in a burning reaction on the 2nd attempt that fractured the end cap while the 1.85 g/cm3 resulted in the burning reaction extinguishing in the first 15 mm on the 2nd attempt. This work will outline the testing details, present the results, and compare them to the relatively high binder content HMX-based LX-04 (85% HMX and 15% Viton) and ultra-fine TATB results tested under similar confinement. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.
Development of very small-diameter, inductively coupled magnetized plasma device
NASA Astrophysics Data System (ADS)
Kuwahara, D.; Mishio, A.; Nakagawa, T.; Shinohara, S.
2013-10-01
In order to miniaturize a high-density, inductively coupled magnetized plasma or helicon plasma to be applied to, e.g., an industrial application and an electric propulsion field, small helicon device has been developed. The specifications of this device along with the experimental results are described. We have succeeded in generating high-density (˜1019 m-3) plasmas using quartz tubes with very small diameters of 10 and 20 mm, with a radio frequency power ˜1200 and 700 W, respectively, in the presence of the magnetic field less than 1 kG.
Development of very small-diameter, inductively coupled magnetized plasma device.
Kuwahara, D; Mishio, A; Nakagawa, T; Shinohara, S
2013-10-01
In order to miniaturize a high-density, inductively coupled magnetized plasma or helicon plasma to be applied to, e.g., an industrial application and an electric propulsion field, small helicon device has been developed. The specifications of this device along with the experimental results are described. We have succeeded in generating high-density (~10(19) m(-3)) plasmas using quartz tubes with very small diameters of 10 and 20 mm, with a radio frequency power ~1200 and 700 W, respectively, in the presence of the magnetic field less than 1 kG.
Kawai, Nobuaki; Tsurui, Kenji; Hasegawa, Sunao; Sato, Eiichi
2010-11-01
A single microparticle launching method is described to simulate the hypervelocity impacts of micrometeoroids and microdebris on space structures at the Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency. A microparticle placed in a sabot with slits is accelerated using a rifled two-stage light-gas gun. The centrifugal force provided by the rifling in the launch tube separates the sabot. The sabot-separation distance and the impact-point deviation are strongly affected by the combination of the sabot diameter and the bore diameter, and by the projectile diameter. Using this method, spherical projectiles of 1.0-0.1 mm diameter were launched at up to 7 km/s.
NASA Astrophysics Data System (ADS)
Kawai, Nobuaki; Tsurui, Kenji; Hasegawa, Sunao; Sato, Eiichi
2010-11-01
A single microparticle launching method is described to simulate the hypervelocity impacts of micrometeoroids and microdebris on space structures at the Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency. A microparticle placed in a sabot with slits is accelerated using a rifled two-stage light-gas gun. The centrifugal force provided by the rifling in the launch tube separates the sabot. The sabot-separation distance and the impact-point deviation are strongly affected by the combination of the sabot diameter and the bore diameter, and by the projectile diameter. Using this method, spherical projectiles of 1.0-0.1 mm diameter were launched at up to 7 km/s.
Participation in multilateral effort to develop high performance integrated CPC evacuated collectors
NASA Astrophysics Data System (ADS)
Winston, R.; Ogallagher, J. J.
1992-05-01
The University of Chicago Solar Energy Group has had a continuing program and commitment to develop an advanced evacuated solar collector integrating nonimaging concentration into its design. During the period from 1985-1987, some of our efforts were directed toward designing and prototyping a manufacturable version of an Integrated Compound Parabolic Concentrator (ICPC) evacuated collector tube as part of an international cooperative effort involving six organizations in four different countries. This 'multilateral' project made considerable progress towards a commercially practical collector. One of two basic designs considered employed a heat pipe and an internal metal reflector CPC. We fabricated and tested two large diameter (125 mm) borosilicate glass collector tubes to explore this concept. The other design also used a large diameter (125 mm) glass tube but with a specially configured internal shaped mirror CPC coupled to a U-tube absorber. Performance projections in a variety of systems applications using the computer design tools developed by the International Energy Agency (IEA) task on evacuated collectors were used to optimize the optical and thermal design. The long-term goal of this work continues to be the development of a high efficiency, low cost solar collector to supply solar thermal energy at temperatures up to 250 C. Some experience and perspectives based on our work are presented and reviewed. Despite substantial progress, the stability of research support and the market for commercial solar thermal collectors were such that the project could not be continued. A cooperative path involving university, government, and industrial collaboration remains the most attractive near term option for developing a commercial ICPC.
[Quantitative Evaluation of Metal Artifacts on CT Images on the Basis of Statistics of Extremes].
Kitaguchi, Shigetoshi; Imai, Kuniharu; Ueda, Suguru; Hashimoto, Naomi; Hattori, Shouta; Saika, Takahiro; Ono, Yoshifumi
2016-05-01
It is well-known that metal artifacts have a harmful effect on the image quality of computed tomography (CT) images. However, the physical property remains still unknown. In this study, we investigated the relationship between metal artifacts and tube currents using statistics of extremes. A commercially available phantom for measuring CT dose index 160 mm in diameter was prepared and a brass rod 13 mm in diameter was placed at the centerline of the phantom. This phantom was used as a target object to evaluate metal artifacts and was scanned using an area detector CT scanner with various tube currents under a constant tube voltage of 120 kV. Sixty parallel line segments with a length of 100 pixels were placed to cross metal artifacts on CT images and the largest difference between two adjacent CT values in each of 60 CT value profiles of these line segments was employed as a feature variable for measuring metal artifacts; these feature variables were analyzed on the basis of extreme value theory. The CT value variation induced by metal artifacts was statistically characterized by Gumbel distribution, which was one of the extreme value distributions; namely, metal artifacts have the same statistical characteristic as streak artifacts. Therefore, Gumbel evaluation method makes it possible to analyze not only streak artifacts but also metal artifacts. Furthermore, the location parameter in Gumbel distribution was shown to be in inverse proportion to the square root of a tube current. This result suggested that metal artifacts have the same dose dependence as image noises.
NASA Astrophysics Data System (ADS)
Ahmed, Asif; Ferdous, Imam Ul.; Saha, Sumon
2017-06-01
In the present study, three-dimensional numerical simulation of two shell-and-tube heat exchangers (STHXs) with conventional segmental baffles (STHXsSB) and continuous helical baffle (STHXsHB) is carried out and a comparative study is performed based on the simulation results. Both of the STHXs contain 37 tubes inside a 500 mm long and 200 mm diameter shell and mass flow rate of shell-side fluid is varied from 0.5 kg/s to 2 kg/s. At first, physical and mathematical models are developed and numerically simulated using finite element method (FEM). For the validation of the computational model, shell-side average nusselt number (Nus) is calculated from the simulation results and compared with the available experimental results. The comparative study shows that STHXsHB has 72-127% higher heat transfer coefficient per unit pressure drop compared to the conventional STHXsSB for the same shell-side mass flow rate. Moreover, STHXsHB has 59-63% lower shell-side pressure drop than STHXsSB.
A drift chamber with a new type of straws for operation in vacuum
NASA Astrophysics Data System (ADS)
Azorskiy, N.; Glonti, L.; Gusakov, Yu.; Elsha, V.; Enik, T.; Kakurin, S.; Kekelidze, V.; Kislov, E.; Kolesnikov, A.; Madigozhin, D.; Movchan, S.; Polenkevich, I.; Potrebenikov, Yu.; Samsonov, V.; Shkarovskiy, S.; Sotnikov, S.; Zinchenko, A.; Danielsson, H.; Bendotti, J.; Degrange, J.; Dixon, N.; Lichard, P.; Morant, J.; Palladino, V.; Gomez, F. Perez; Ruggiero, G.; Vergain, M.
2016-07-01
A 2150×2150 mm2 registration area drift chamber capable of working in vacuum is presented. Thin-wall tubes (straws) of a new type are used in the chamber. A large share of these 9.80 mm diameter drift tubes are made in Dubna from metalized 36 μm Mylar film welded along the generatrix using an ultrasonic welding machine created at JINR. The main features of the chamber and some characteristics of the drift tubes are described. Four such chambers with the X, Y, U, V coordinates each, containing 7168 straws in total, are designed and produced at JINR and CERN. They are installed in the vacuum volume of the NA62 setup in order to study the ultra-rare decay K+ →π+ vv bar and to search for and study rare meson decays. In autumn 2014 the chambers were used for the first time for the data taking in the experimental run of the NA62 at CERN's SPS.
NASA Astrophysics Data System (ADS)
Nagai, Keisuke; Kuwabara, Toshihiko; Ilinich, Andrey; Luckey, George
2018-05-01
A servo-controlled tension-internal pressure testing machine with an optical 3D digital image correlation system (DIC) is used to measure the multiaxial deformation behavior of an extruded aluminum alloy tube for a strain range from initial yield to fracture. The outer diameter of the test sample is 50.8 mm and wall thickness 2.8 mm. Nine linear stress paths are applied to the specimens: σɸ (axial true stress component) : σθ (circumferential true stress component) = 1:0, 4:1, 2:1, 4:3, 1:1, 3:4, 1:2, 1:4, and 0:1. The equivalent strain rate is approximately 5 × 10-4 s-1 constant. The forming limit curve (FLC) and forming limit stress curve (FLSC) are also measured. Moreover, the average true stress components inside a localized necking area are determined for each specimen from the thickness strain data for the localized necking area and the geometry of the fracture surface.
On the development of co-axial miniature pulse tube coolers for space applications
NASA Astrophysics Data System (ADS)
Zhou, Y.; Liang, J. T.; Zhu, W. Q.; Cai, J. H.; Ju, Y. L.
2002-05-01
Cryocoolers for cooling infrared sensors in space applications require high reliability, long lifetime, low power and minimum weight. In this paper we report work on a miniature pulse tube cooler specifically designed for such applications. A series of engineering model co-axial miniature pulse tube coolers with a flexure bearing linear compressor of 1 cc swept volume have been designed and fabricated in our laboratory. A theoretical model is established based on the analyses of thermodynamic and hydrodynamic behaviors of oscillatory flows in regenerator, for performance prediction, optimization and as a rough guide in the early stages of system design. An experimental apparatus, including a hot wire anemometer, has been set up to study the flow resistance of regenerators under oscillatory flow conditions. The co-axial, multi-bypass, and symmetric nozzle structure has been used in the coolers. We will present here the performance of two sizes of coolers with 9 mm and 8 mm diameter of cold fingers. The 9 mm cooler currently provides 500 mW net cooling power at 80 K with input power of 47 W, and the 8 mm cooler, provides 450 mW at 80 K with 51 W input power with a 65% efficient compressor. The cold fingers of our co-axial pulse tube coolers have the similar size of miniature Stirling coolers and are the only one that could meet the geometry specifications of the Standard Advance Dewar Assembly (SADA) for thermal imaging systems in most military applications.
NASA Astrophysics Data System (ADS)
Rahman, Md. Lutfor; Afrose, Tonima; Tahmina, Halima Khatun; Rinky, Rumana Parvin; Ali, Mohammad
2016-07-01
Pulsating heat pipe (PHP) is a new innovation in the modern era of miniaturizes thermal management system for its higher heating and cooling capacity. The objective of this experiment is to observe the performance of open loop pulsating heat pipe using two fluids at different filling ratios. This OLPHP is a copper capillary tube of 2.5mm outer diameter and 2mm inner diameter. It consists of 8 loops where the evaporative section is 50mm, adiabatic section is 120mm and condensation section is 80mm. The experiment is conducted with distilled water and acetone at 40%, 50%, 60%, and 70% filling ratios where 0° (vertical) is considered as definite angle of inclination. Distilled water and acetone are selected as working fluids considering their different latent heat of vaporization and surface tension. It is found that acetone shows lower thermal resistance than water at all heat inputs. Best performance of acetone is attained at 70% filling ratio. Water displays better heat transfer capability at 50% filling ratio.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsai, H; Hu, Y; Hwang, Y
Purpose: This study was to investigate size-specific dose estimates (SSDE) for routine adult abdominal CT examinations in Taiwan. Methods: A national survey was conducted in Taiwan in 2014 to investigate SSDEs for routine adult abdominal CT examinations. The hospitals involved in this study provided CT images of their typical patients. The CT image in the level of the middle liver was selected to record the corresponding tube current, slice mAs or effective mAs. The image was also used to estimate the dimensions of patient as measuring the lengths in the anterior to posterior (AP) and lateral (LAT) directions. The effectivemore » diameter was then calculated from AP and LAT, and used to look up conversion factors in the AAPM 204 report. The volume CTDI (CTDIvol) for each CT unit was measured on sites using a 32-cm cylindrical standard dose phantom and a calibrated pencil-type ionization chamber. Individual patient’s SSDEs were then calculated from the corresponding SSDE conversion factor and the CTDIvol. Results: The study cohort included 111 CT units. The ratio of turning on automatic tube current modulation (ATCM) or not is 88:23. Effective diameters are 258.7±25.1 mm (167–366 mm). 99.3% of typical patients selected by each hospital have smaller effective diameter than the 32-cm dosimetry phantom. Adult abdomenal SSDE is 17.5 ± 8.8 mGy (1.9-58 mGy). The SSDE seems to decrease as the effective diameter increases as the ATCM turns off, and independent with the effective diameter as the ATCM turns on. Conclusion: The SSDE for typical patients in Taiwan was investigated. We continue to complete this investigation in 2015 to include more valid data to establish SSDE reference level in Taiwan. This study was financially supported by the Atomic Energy Council in Taiwan.« less
Propagation of atmospheric-pressure ionization waves along the tapered tube
NASA Astrophysics Data System (ADS)
Xia, Yang; Wang, Wenchun; Liu, Dongping; Yan, Wen; Bi, Zhenhua; Ji, Longfei; Niu, Jinhai; Zhao, Yao
2018-02-01
Gas discharge in a small radius dielectric tube may result in atmospheric pressure plasma jets with high energy and density of electrons. In this study, the atmospheric pressure ionization waves (IWs) were generated inside a tapered tube. The propagation behaviors of IWs inside the tube were studied by using a spatially and temporally resolved optical detection system. Our measurements show that both the intensity and velocity of the IWs decrease dramatically when they propagate to the tapered region. After the taper, the velocity, intensity, and electron density of the IWs are improved with the tube inner diameter decreasing from 4.0 to 0.5 mm. Our analysis indicates that the local gas conductivity and surface charges may play a role in the propagation of the IWs under such a geometrical constraint, and the difference in the dynamics of the IWs after the taper can be related to the restriction in the size of IWs.
Susceptibility measurements on the superconducting properties of Nb-Ge alloys
NASA Technical Reports Server (NTRS)
Rathz, T. J.
1981-01-01
A susceptibility apparatus to measure superconducting properties of samples made in the MSFC Drop Tube was used to measure the transition temperature (Tc) and susceptibilities of Nb and Nb Ge Alloys prepared in bulk spherical (2-4 mm diameter) form using a 32 m drop tube in which containerless low gravity solidification could take place. Results indicate that a drop tube processing environment was beneficial for increasing the Tc of the superconducting phase of the material over that of arc melted material. The increase in Tc is found to be related to the amount of solidification of the total sample that took place before reaching the bottom of the drop tube. In phase and quadrature phase measurements of the specimen's susceptibility indicated that some improvement in homogeneity takes place in drop tube processing. These phase measurements also indicated little or no shielding of a lower Tc phase by a higher Tc filamentary structure.
NASA Astrophysics Data System (ADS)
Cegielski, M.; Hernik, S.; Kula, M.; Oleksy, M.
This section is based on paper [96], the objective of which is modeling of the unilateral damage effect in the aluminum alloy Al-2024, based on the nonlinear Armstrong-Frederick model Eq. 6.60 enriched by damage [170] with a continuous damage deactivation concept. The simulation is proposed in order to model the phenomenon of nonsymmetric hysteresis loop evolution due to different damage growth under tension and compression observed in the experiment [1]. The specimens used in the experiment were made of aluminum alloy Al-2024 (Table 7.1). The tests were carried out at room temperature on a servo-hydraulic INSTRON machine type 1340, using thin-walled tubes of the dimensions: internal diameter 15 mm and external diameter 18 mm.
NASA Astrophysics Data System (ADS)
Arya, Bheemsha; Nayak, B. Ramesh; Shivakumara, N. V.
2018-04-01
In practice the refrigerants are being used in the conventional refrigeration system to get the required cooling effect. These refrigerants produce Chlorofluorocarbons (CFCs) and Hydro chlorofluorocarbons (HCFCs) which are highly harmful to the environment, particularly depleting of ozone layers resulting in green house emissions. In order to overcome these effects, the research needs to be focused on the development of an ecofriendly refrigeration system. The thermoacoustic refrigeration system is one among such system where the sound waves are used to compress and expand the gas particles. This study focuses on the effect of dynamic pressure on the thermoacoustic refrigerator made of aluminium with overall length of 748.82 mm, and the entire inner surface of the resonator tube was coated with 2mm thickness of polyurethane to minimize the heat losses to the atmosphere. Experiments were conducted with different stack geometries i.e. parallel plates having 0.119 mm thick with spacing between the plates maintained at 0.358 mm, 1mm diameter pipes, 2mm diameter pipes and 4 mm diameter pipes. Experiments were also conducted with different drive ratios of 0.6%, 1% and 1.6% for a constant dynamic pressure of 2 bar and 10 bar for helium and air as working medium. The results were plotted with the help of graphs, the variation of coefficient of performance (COP) and the relative coefficient of performance (COPR) for the above said conditions were calculated.
NASA Technical Reports Server (NTRS)
Landry, K.
2005-01-01
Studies were performed in order to characterize the thrust augmentation potential of an ejector in a Pulse Detonation Engine application. A 49-mm diameter tube of 0.914-m length was constructed with one open end and one closed end. Ethylene, oxygen, and nitrogen were introduced into the tube at the closed end through the implementation of a fast mixing injector. The tube was completely filled with a stoichiometric mixture containing a one to one molar ratio of nitrogen to oxygen. Ethylene was selected as the fuel due to its detonation sensitivity and the molar ratio of the oxidizer was chosen for heat transfer purposes. Detonations were initiated in the tube through the use of a spark ignition system. The PDE was operated in a multi-cycle mode at frequencies ranging from 20-Hz to 50-Hz. Baseline thrust measurements with no ejector present were performed while operating the engine at various frequencies and compared to theoretical estimates. The baseline values were observed to agree with the theoretical model at low operating frequencies and proved to be increasingly lower than the predicted values as the operating frequency was increased. The baseline thrust measurements were observed to agree within 15 percent of the model for all operating frequencies. A straight 152-mm diameter ejector was installed and thrust augmentation percentages were measured. The length of the ejector was varied while the overlap percentage (percent of the ejector length which overlapped the tube) was maintained at 25 percent for all tests. In addition, the effect of ejector inlet geometry was investigated by comparing results with a straight inlet to those of a 38-mm inlet diameter. The thrust augmentation of the straight inlet ejector proved to be independent of engine operating frequency, augmenting thrust by 40 percent for the 0.914-m length ejector. In contrast, the rounded lip ejector of the same length seemed to be highly dependent on the engine operating frequency. An optimum operating frequency observed with the rounded inlet occurred at an operating frequency of 30-Hz, resulting in thrust augmentation percentages greater than 100 percent. The effect that the engine operating frequency had on thrust augmentation levels attained with an ejector was characterized and optimum performance parameters were established. Insight into the frequency dependent nature of the ejector performance was pursued. Suggestions for future experiments which are needed to fully understand the means in which thrust augmentation is achieved in a PDE-ejector configuration were noted.
Near-limit propagation of gaseous detonations in narrow annular channels
NASA Astrophysics Data System (ADS)
Gao, Y.; Ng, H. D.; Lee, J. H. S.
2017-03-01
New results on the near-limit behaviors of gaseous detonations in narrow annular channels are reported in this paper. Annular channels of widths 3.2 and 5.9 mm were made using circular inserts in a 50.8 mm-diameter external tube. The length of each annular channel was 1.8 m. Detonations were initiated in a steel driver tube where a small volume of a sensitive C2H2+ 2.5O2 mixture was injected to facilitate detonation initiation. A 2 m length of circular tube with a 50.8 mm diameter preceded the annular channel so that a steady Chapman-Jouguet (CJ) detonation was established prior to entering the annular channel. Four detonable mixtures of C2H2 {+} 2.5O2 {+} 85 % Ar, C2H2 {+} 2.5O2 {+} 70 % Ar, C3H8 {+} 5O2, and CH4 {+} 2O2 were used in the present study. Photodiodes spaced 10 cm throughout the length of both the annular channel and circular tube were used to measure the detonation velocity. In addition, smoked foils were inserted into the annular channel to monitor the cellular structure of the detonation wave. The results show that, well within the detonability limits, the detonation wave propagates along the channel with a small local velocity fluctuation and an average global velocity can be deduced. The average detonation velocity has a small deficit of 5-15 % far from the limits and the velocity rapidly decreases to 0.7V_{CJ}-0.8V_{CJ} when the detonation propagates near the limit. Subsequently, the fluctuation of local velocity also increases as the decreasing initial pressure approaches the limit. In the two annular channels used in this work, no galloping detonations were observed for both the stable and unstable mixtures tested. The present study also confirms that single-headed spinning detonation occurs at the limit, as in a circular tube, rather than the up and down "zig zag" mode in a two-dimensional, rectangular channel.
Iqbal, Shams I; Molgaard, Christopher; Williamson, Christina; Flacke, Sebastian
2014-07-01
To evaluate the feasibility and efficacy of pneumothorax creation and chest tube insertion before computed tomography (CT)-guided coil localization of small peripheral lung nodules for video-assisted thoracoscopic surgical (VATS) wedge resection. From May 2011 to October 2013, 21 consecutive patients (seven men; mean age, 62 y; range, 42-76 y) scheduled for VATS wedge resection required CT-guided coil localization for small, likely nonpalpable peripheral lung lesions at a single institution. Outcomes were evaluated retrospectively for technical success and complications. There were 12 nodules and nine ground-glass opacities. Mean lesion distance from the pleural surface was 15 mm (range, 5-35 mm), and average size was 13 mm (range, 7-30 mm). A pneumothorax was successfully created in all patients with a Veress needle, and a chest tube was inserted. All target lesions were marked successfully, leaving one end of the coil within/beyond the lesion and the other end of the coil in the pleural space. The inserted chest tube was used to insufflate air to widen the pleural space during coil positioning and to aspirate any residual air before transfer of the patient to the operating room holding area. Intraparenchymal hemorrhages smaller than 7 cm in diameter developed in two patients during coil placement. All lesions were successfully resected with VATS. Histologic examinaiton revealed 13 primary adenocarcinomas, four metastases, and four benign lesions. Pneumothorax creation and chest tube placement before CT-guided coil localization of peripheral lung nodules for VATS wedge resection facilitates the deployment of the peripheral end of the coil in the pleural space and provides effective management of procedure-related pneumothorax until surgery. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.
A Large Tracking Detector In Vacuum Consisting Of Self-Supporting Straw Tubes
NASA Astrophysics Data System (ADS)
Wintz, P.
2004-02-01
A novel technique to stretch the anode wire simply by the gas over-pressure inside straw drift tubes reduces the necessary straw weight to an absolute minimum. Our detector will consist of more than 3000 straws filling up a cylindrical tracking volume of 1m diameter and 30cm length. The projected spatial resolution is 200μm. The detector with a total mass of less than 15kg will be operated in vacuum, but will have an added wall thickness of 3mm mylar, only. The detector design, production experience and first results will be discussed.
Benett, William J.; Krulevitch, Peter A.
2001-01-01
A miniature connector for introducing microliter quantities of solutions into microfabricated fluidic devices. The fluidic connector, for example, joins standard high pressure liquid chromatography (HPLC) tubing to 1 mm diameter holes in silicon or glass, enabling ml-sized volumes of sample solutions to be merged with .mu.l-sized devices. The connector has many features, including ease of connect and disconnect; a small footprint which enables numerous connectors to be located in a small area; low dead volume; helium leak-tight; and tubing does not twist during connection. Thus the connector enables easy and effective change of microfluidic devices and introduction of different solutions in the devices.
Estimation of aneurysm wall stresses created by treatment with a shape memory polymer foam device
Hwang, Wonjun; Volk, Brent L.; Akberali, Farida; Singhal, Pooja; Criscione, John C.
2012-01-01
In this study, compliant latex thin-walled aneurysm models are fabricated to investigate the effects of expansion of shape memory polymer foam. A simplified cylindrical model is selected for the in-vitro aneurysm, which is a simplification of a real, saccular aneurysm. The studies are performed by crimping shape memory polymer foams, originally 6 and 8 mm in diameter, and monitoring the resulting deformation when deployed into 4-mm-diameter thin-walled latex tubes. The deformations of the latex tubes are used as inputs to physical, analytical, and computational models to estimate the circumferential stresses. Using the results of the stress analysis in the latex aneurysm model, a computational model of the human aneurysm is developed by changing the geometry and material properties. The model is then used to predict the stresses that would develop in a human aneurysm. The experimental, simulation, and analytical results suggest that shape memory polymer foams have potential of being a safe treatment for intracranial saccular aneurysms. In particular, this work suggests oversized shape memory foams may be used to better fill the entire aneurysm cavity while generating stresses below the aneurysm wall breaking stresses. PMID:21901546
Characterization of Friction Stir Welded Tubes by Means of Tube Bulge Test
NASA Astrophysics Data System (ADS)
D'Urso, G.; Longo, M.; Giardini, C.
2011-05-01
Mechanical properties of friction stir welded joints are generally evaluated by means of conventional tensile test. This testing method might provide insufficient information because maximum strain obtained in tensile test before necking is small; moreover, the application of tensile test is limited when the joint path is not linear or even when the welds are executed on curved surfaces. Therefore, in some cases, it would be preferable to obtain the joints properties from other testing methods. Tube bulge test can be a valid solution for testing circumferential or longitudinal welds executed on tubular workpieces. The present work investigates the mechanical properties and the formability of friction stir welded tubes by means of tube bulge tests. The experimental campaign was performed on tubular specimens having a thickness of 3 mm and an external diameter of 40 mm, obtained starting from two semi-tubes longitudinally friction stir welded. The first step, regarding the fabrication of tubes, was performed combining a conventional forming process and friction stir welding. Sheets in Al-Mg-Si-Cu alloy AA6060 T6 were adopted for this purpose. Plates having a dimension of 225×60 mm were bent (with a bending axis parallel to the main dimension) in order to obtain semi-tubes. A particular care was devoted to the fabrication of forming devices (punch and die) in order to minimize the springback effects. Semi-tubes were then friction stir welded by means of a CNC machine tool. Some preliminary tests were carried out by varying the welding parameters, namely feed rate and rotational speed. A very simple tool having flat shoulder and cylindrical pin was used. The second step of the research was based on testing the welded tubes by means of tube bulge test. A specific equipment having axial actuators with a conical shape was adopted for this study. Some analyses were carried out on the tubes bulged up to a certain pressure level. In particular, the burst pressure and the wall thickness were measured for each tested tube.
Experimental investigation of electron guns for THz microwave vacuum amplifiers
NASA Astrophysics Data System (ADS)
Burtsev, A. A.; Grigor'ev, Yu. A.; Navrotsky, I. A.; Rogovin, V. I.; Sakhadzhi, G. V.; Shumikhin, K. V.
2016-05-01
Single-sheet and multiple beam electron emitters based on thermionic minicathodes for terahertz traveling-wave tubes have been studied. Data are presented for impregnated blade thermionic cathode with dimensions 0.1 × 0.7 mm and a maximum current density of 114 A/cm2 in a pulsed mode. A variant of the five-beam electron gun with 0.25-mm-diameter cylindrical minicathodes in cells of a control grid is proposed that provides a current density of 85.5 A/cm2 at a grid potential of 900-1000 V.
A Piezoelectric Micromotor with a Stator of φ=1.6 mm and l=4 mm Using Bulk PZT
NASA Astrophysics Data System (ADS)
Cagatay, Serra; Koc, Burhanettin; Moses, Paul; Uchino, Kenji
2004-04-01
The smallest discrete piezoelectric ultrasonic motor using bulk ceramics was developed. We are proposing basically a two-part motor: stator and rotor. The stator of the present motor consists of a hollow metal brass tube with outer diameter of 1.6 mm, inner diameter of 0.8 mm and length of only 4 mm with 2 PZT plates bonded onto it. Owing to the asymmetrical stator surface, two degenerated orthogonal bending modes were slightly split, resulting in a wobbling motion. Thus, the motor can be driven by a single driving source. The rotor is a spring, which is basically different from previous designs, pressed at both ends to the stator by a pair of ferrules. Consequently, the length of the whole motor assembly was reduced significantly; a final motor length of only 5 mm was obtained. The working frequency under zero load was approximately 227-233 kHz. Although the size is small, relatively high power was obtained under an optimized load condition: torque of 0.06 mNm, maximum power of 3.2 mW with a speed of 118 rad/s, and maximum efficiency of 11% under 48 Vrms at 221 kHz.
de MOURA-JÚNIOR, Luiz Gonzaga; de CASTRO-FILHO, Heládio Feitosa; MACHADO, Francisco Heine Ferreira; BABADOPULOS, Rodrigo Feitosa; FEIJÓ, Francisca das Chagas; FERNANDES, Silvana Duarte
2014-01-01
Background The laparoscopic access, with its classically known benefits, pushed implementation in other components, better ergonomy and aesthetic aspect. Aim To minimize the number and diameter of traditional portals using miniport and flexible liver retractor on bariatric surgery. Method This prospective study was used in patients with less than 45 kg/m2, with peripheral fat, normal umbilicus implantation, without previous abdominoplasties. Were used one 30o optical device with 5 mm in diameter, four accesses (one mini of 3 mm to the left hand of the surgeon, one of 5 mm to the right hand alternating with optics, one of 12 mm for umbilical for surgical maneuvers as dissection, clipping, in/out of gauze, and one portal of 5 mm for the assistant surgeon), resulting in a total of 25 mm linear incision; additionally, one flexible liver retractor (covered with a nelaton probe to protect the liver parenchyma, anchored in the right diaphragmatic pillar and going out through the surgeon left portal) to visualize the esophagogastric angle. Results In selected patients (48 operations), gastric bypass was performed at a similar time to the procedures with larger diameters (5 or 6 portals and 10 mm optics, with sum of linear incision of 42 mm) including oversuture line on excluded stomach, gastric tube and mesenteric closing. The non sutured portal of 3 mm and the two of 5 mm with subdermal sutures, were hardly visible in the folds of the skin; the one of 12 mm was buried inside the umbilicus or in the abdominoplasty incision. Conclusion Minimizing portals is safe, effective, good ergonomic alternative with satisfactory aesthetic profile without need for specific instruments, new learning curve and limited movement of the instruments, as required by the single port. PMID:25409973
Diffraction on heavy samples at STRESS-SPEC using a robot system
NASA Astrophysics Data System (ADS)
Al-Hamdany, N.; Gan, W. M.; Randau, C.; Brokmeier, H.-G.; Hofmann, M.
2015-04-01
The material science diffractometer STRESS-SPEC has high flux and a high flexible monochromator arrangement to optimize the needed wavelength. Many specific sample handling stages and sample environments are available. One of them is a Staubli RX 160 robot with nominal load capacity of 20 kg and more freedom for texture mapping than the Huber 512 Eulerian type cradle. Demonstration experiments of non-destructive pole figures and strain measurements of Cu-tube segments weighing 12 kg weight and 250 mm in length and 140 mm diameter have been carried out. The residual strains measured by the robot and by the XYZ- stage fit quite well, that means the robot is reliable for strain measurements. The texture of the Cu-tube has dominant recrystallization texture components represented by the cube and the rotated cube.
U-PHOS Project: Development of a Large Diameter Pulsating Heat Pipe Experiment on board REXUS 22
NASA Astrophysics Data System (ADS)
Nannipieri, P.; Anichini, M.; Barsocchi, L.; Becatti, G.; Buoni, L.; Celi, F.; Catarsi, A.; Di Giorgio, P.; Fattibene, P.; Ferrato, E.; Guardati, P.; Mancini, E.; Meoni, G.; Nesti, F.; Piacquadio, S.; Pratelli, E.; Quadrelli, L.; Viglione, A. S.; Zanaboni, F.; Mameli, M.; Baronti, F.; Fanucci, L.; Marcuccio, S.; Bartoli, C.; Di Marco, P.; Bianco, N.; Marengo, M.; Filippeschi, S.
2017-01-01
U-PHOS Project aims at analysing and characterising the behaviour of a large diameter Pulsating Heat Pipe (PHP) on board REXUS 22 sounding rocket. A PHP is a passive thermal control device where the heat is efficiently transported by means of the self-sustained oscillatory fluid motion driven by the phase change phenomena. Since, in milli-gravity conditions, buoyancy forces become less intense, the PHP diameter may be increased still maintaining the slug/plug typical flow pattern. Consequently, the PHP heat power capability may be increased too. U-PHOS aims at proving that a large diameter PHP effectively works in milli-g conditions by characterizing its thermal response during a sounding rocket flight. The actual PHP tube is made of aluminum (3 mm inner diameter, filled with FC-72), heated at the evaporator by a compact electrical resistance, cooled at the condenser by a Phase Change Material (PCM) embedded in a metallic foam. The tube wall temperatures are recorded by means of Fibre Bragg Grating (FBG) sensors; the local fluid pressure is acquired by means of a pressure transducer. The present work intends to report the actual status of the project, focusing in particular on the experiment improvements with respect to the previous campaign.
A High-Resolution Endoscope of Small Diameter Using Electromagnetically Vibration of Single Fiber
NASA Astrophysics Data System (ADS)
Matsunaga, Tadao; Hino, Ryunosuke; Makishi, Wataru; Esashi, Masayoshi; Haga, Yoichi
For high resolution visual inspection in the narrow space of the human body, small diameter endoscope has been developed which utilize electromagnetically vibration of single fiber. Thin endoscopes are effective for inspection in the narrow space of the human body, for example, in the blood vessel, lactiferous duct for detection infiltration of breast cancer, and periodontal gap between gingiva and tooth. This endoscope consists of single optical fiber and photofabricated driving coils. A collimator lens and a cylindrical permanent magnet are fixed on the optical fiber, and the tilted driving coils have been patterned on a 1.08 mm outer diameter thin tube. The fiber is positioned at the center of the tube which is patterned the coils. When an electrical alternating current at the resonance frequency is supplied to the coils, the permanent magnet which is fixed to the fiber is vibrated electromagnetically and scanned one or two dimensionally. This paper reports small diameter endoscope by using electromagnetically vibration of single fiber. Optical coherence tomography imaging has also been carried out with the fabricated endoscope and cross-section image of sub-surface skin of thumb was observed.
Abdominal drainage following cholecystectomy: high, low, or no suction?
McCormack, T. T.; Abel, P. D.; Collins, C. D.
1983-01-01
A prospective trial to assess the effect of suction in an abdominal drain following cholecystectomy was carried out. Three types of closed drainage system were compared: a simple tube drain, a low negative pressure drain, and a high negative pressure drain: 120 consecutive patients undergoing cholecystectomy were randomly allocated to one of the three drainage groups. There was no significant difference in postoperative pyrexia, wound infection, chest infection, or hospital stay. This study failed to demonstrate any clinically useful difference between high negative pressure, low negative pressure, and static drainage system were compared: a simple tube drain, a low negative used, suction is not necessary and a simple tube drain (greater than 6 mm internal diameter) is the most effective form of drainage. PMID:6614773
Li, Y; Zhou, J; Zhang, J
2000-01-01
To insert a tube into pericardial cavity as an emergent measure of diagnosis and treatment in patients with malignant pericardial effusion. Pericardial puncture was followed by insertion of drainage tube (diameter = 1.8 mm) through the puncture needle. The effusion collected was examined for cancer cells. After drainage, chemotherapeutic agents were administered. Four hours later, drainage was continued for 2 days (< or = 30 ml pericardial fluid drained in 24 hr) and the tube was removed. In 34 cases with malignant pericardial effusion, tube draining was successful to relieve cardiac temponade within 15-60 minutes. Clots were present in 91.2% of the cases and cancer diagnosis was confirmed in all of them. The cytologic diagnosis of effusion was positive in 61.8%, and the cyto-pathologic typing of clots was 81.0%. The difference was statistically significant. When the results of the 2 examinations were put together, the positive rate increased to 94.1%. Tube drainage of malignant pericardial effusion is useful in diagnosis and emergency treatment.
NASA Astrophysics Data System (ADS)
Xu, Li; Huang, Chang-Xu; Huang, Zhen-Fei; Sun, Qiang; Li, Jie
2018-05-01
The ice crystal particles are easy to enter into the seawater cooling system of polar ship together with seawater when it sails in the Arctic. They are easy to accumulate in the pipeline, causing serious blockage of the cooling pipe. In this study, the flow and melting characteristics of ice particles-seawater two-phase flow in inlet straight pipe of shell-and-tube heat exchanger were numerically simulated by using Eulerian-Eulerian two-fluid model coupled with the interphase heat and mass transfer model. The influences of inlet ice packing factor, ice crystal particle diameter, and inlet velocity on the distribution and melting characteristics of ice crystals were investigated. The degree of asymmetry of the distribution of ice crystals in the cross section decreases gradually when the IPF changes from 5 to 15%. The volume fractions of ice crystals near the top of the outlet cross section are 19.59, 19.51, and 22.24% respectively for ice packing factor of 5, 10 and 15%. When the particle diameter is 0.5 mm, the ice crystals are gradually stratified during the flow process. With particle diameters of 1.0 and 2.0 mm, the region with the highest volume fraction of ice crystals is a small circle and the contours in the cloud map are compact. The greater the inlet flow velocity, the less stratified the ice crystals and the more obvious the turbulence on the outlet cross section. The average volume fraction of ice crystals along the flow direction is firstly rapidly reduced and then stabilized after 300 mm.
Argon hollow cathode. M.S. Thesis; [propellants for ion bombardment thrusters
NASA Technical Reports Server (NTRS)
Rehn, L. A.
1976-01-01
An interest in alternate propellants for ion-bombardment thrusters, together with ground applications of this technology, has prompted consideration of argon. Several variations of conventional hollow cathode designs were tried, but the bulk of the testing used a hollow tube with an internal tungsten emitter and an orifice at one end. The optimum cathode tube diameter was found to be in the range of 1.0-2.5 cm, somewhat larger than those used for cesium and mercury. Optimum orifice diameter depended on operating conditions, and varied from 0.5 to 5 mm. Biasing the internal emitter negative relative to the cathode chamber reduced the external coupling voltage and should therefore improve orifice lifetime. The expected effect of this bias on emitter lifetime was less clear. Lifetime tests were not conducted as part of this investigation, but several designs show promise of long lifetime in specific applications.
NASA Astrophysics Data System (ADS)
Mishra, J. S.; Sakamoto, R.; Motojima, G.; Matsuyama, A.; Yamada, H.
2011-02-01
A low speed single barrel pellet injector, using a mechanical punch device has been developed for alternative injection in the large helical device. A pellet is injected by the combined operation of a mechanical punch and a pneumatic propellant system. The pellet shape is cylindrical, 3 mm in diameter and 3 mm in length. Using this technique the speed of the pellet can be controlled flexibly in the range of 100-450 m/s, and a higher speed can be feasible for a higher gas pressure. The injector is equipped with a guide tube selector to direct the pellet to different injection locations. Pellets are exposed to several curved parts with the curvature radii Rc = 0.8 and 0.3 m when they are transferred in guided tubes to the respective injection locations. Pellet speed variation with pressure at different pellet formation temperatures has been observed. Pellet intactness tests through these guide tubes show a variation in the intact speed limit over a range of pellet formation temperatures from 6.5 to 9.8 K. Pellet speed reduction of less than 6% has been observed after the pellet moves through the curved guide tubes.
Shear thinning effects on blood flow in straight and curved tubes
NASA Astrophysics Data System (ADS)
Cherry, Erica M.; Eaton, John K.
2013-07-01
Simulations were performed to determine the magnitude and types of errors one can expect when approximating blood in large arteries as a Newtonian fluid, particularly in the presence of secondary flows. This was accomplished by running steady simulations of blood flow in straight and curved tubes using both Newtonian and shear-thinning viscosity models. In the shear-thinning simulations, the viscosity was modeled as a shear rate-dependent function fit to experimental data. Simulations in straight tubes were modeled after physiologically relevant arterial flows, and flow parameters for the curved tube simulations were chosen to examine a variety of secondary flow strengths. The diameters ranged from 1 mm to 10 mm and the Reynolds numbers from 24 to 1500. Pressure and velocity data are reported for all simulations. In the straight tube simulations, the shear-thinning flows had flattened velocity profiles and higher pressure gradients compared to the Newtonian simulations. In the curved tube flows, the shear-thinning simulations tended to have blunted axial velocity profiles, decreased secondary flow strengths, and decreased axial vorticity compared to the Newtonian simulations. The cross-sectionally averaged pressure drops in the curved tubes were higher in the shear-thinning flows at low Reynolds number but lower at high Reynolds number. The maximum deviation in secondary flow magnitude averaged over the cross sectional area was 19% of the maximum secondary flow and the maximum deviation in axial vorticity was 25% of the maximum vorticity.
Fan-beam scanning laser optical computed tomography for large volume dosimetry
NASA Astrophysics Data System (ADS)
Dekker, K. H.; Battista, J. J.; Jordan, K. J.
2017-05-01
A prototype scanning-laser fan beam optical CT scanner is reported which is capable of high resolution, large volume dosimetry with reasonable scan time. An acylindrical, asymmetric aquarium design is presented which serves to 1) generate parallel-beam scan geometry, 2) focus light towards a small acceptance angle detector, and 3) avoid interference fringe-related artifacts. Preliminary experiments with uniform solution phantoms (11 and 15 cm diameter) and finger phantoms (13.5 mm diameter FEP tubing) demonstrate that the design allows accurate optical CT imaging, with optical CT measurements agreeing within 3% of independent Beer-Lambert law calculations.
Georgiadis, George S; Argyriou, Christos; Valsamidou, Christina D; Nikova, Alexandrina S; Lazarides, Miltos K
2018-05-01
Unfavorable anatomy is one of the major limitations of endovascular aortic aneurysm repair (EVAR) with specifically adverse proximal neck morphology excluding many patients from receiving the standard endograft devices. Thoracic tube endografts have been used to overcome the issue of wide infrarenal necks, either as a sole device (single tubes or double tubes using the trombone technique) or as the proximal part of a bifurcated device fixed to the aortic bifurcation or infrarenally oriented. However, custom-made large proximal diameter bifurcated endograft designs have never been used. We present the case of a 56-year-old man with Marfan syndrome, suffering abdominal aortic aneurysm (AAA) enlargement from a type Ib endoleak after previous EVAR with 2 Endofit tube endografts (trombone technique). He was considered unfit for open surgery while possible alternatives such as fenestrated endovascular AAA repair and chimney technique were excluded. The patient was treated with a custom-made 44-mm proximal diameter, bifurcated Bolton Medical Treovance device with technical and clinical success. No immediate or perioperative complications were noted. Follow-up after 6 months showed graft patency and no endoleak of any type. This alternative technique for hostile proximal neck management is promising and needs long-term follow-up; an issue which is discussed within the broader context of custom-made device regulations. Copyright © 2018 Elsevier Inc. All rights reserved.
Microwave transmission measurements through a magnetic photonic crystal
NASA Astrophysics Data System (ADS)
Radwan, Mohamed Zein; Dewar, Graeme
We have measured the 12 - 18 GHz microwave transmission through, and the reflection from, a nickel zinc ferrite penetrated by a wire lattice. The metamaterial efficiently transmitted microwaves under conditions for which the index of refraction was negative. The wires, 0.29 mm in diameter, were threaded through Teflon tubes and centered in holes 1.7 mm in diameter drilled through the ferrite. The holes formed a square array with a lattice constant of 3.0 mm. A ferrite sample containing the wire array filled a length of 3.0 cm inside standard WR-62 waveguide and a static magnetic field between 0.042 and 13.0 kOe was applied parallel to the wires. We measured the transmission relative to an open waveguide and the reflection relative to a reflective metal plate across the waveguide face. We observed transmission modes at combinations of magnetic field and microwave frequency for which both the permeability of the ferrite and permittivity of the wire array were negative.
Amperometric Biosensors Based on 3-Dimensional Hydrogel-Forming Epoxy Networks
1993-05-24
are epoxy- embedded and contained in a 0.3mm diameter biocompatible polyimide tubing. The ensemble of epoxy-embedded fiber tips is coated with the...electrode is then overcoated with a biocompatible film. The electrode’s sensitivity is 2.5xI0 2 A cm’ 2 M 1. It can be stored at 40 C for 4 months with no
Code of Federal Regulations, 2014 CFR
2014-10-01
... covered with protective tubing. A set of two pieces of poly braid rope covered with light duty garden hose... line (400-lb test) or polypropylene multistrand material, known as braided or tarred mainline, and must... m) lengths of poly braid rope (3/8-inch (9.52 mm) diameter suggested), each covered with an 8-inch...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barzi, E.; Limon, P. J.; Yamada, R.
Fermilab is developing 11 T superconducting dipole magnets for future accelerators based on Nb/sub 3/Sn conductors. Multifilamentary Nb/sub 3/Sn strands 1 mm in diameter produced with the modified jelly roll and powder-in-tube technologies were purchased from OST and SMI respectively. They are herein fully characterized by I/sub c/, n-value, residual resistivity ratio, and magnetization. Results of heat treatment optimization studies are also presented for the OST strand.
Development and testing of a sampling device for the analyses of suspended sediment concentrations
NASA Astrophysics Data System (ADS)
Schletterer, Martin; Reindl, Robert; Unterlercher, Franz; Hauer, Christoph
2017-04-01
Suspended sediment concentrations are not equal in time as well as within a cross section. For calibration, sampling is needed within a cross profile (using e.g. sampler US P-61-A1) or nearby of a SSC sensor. However, due to insufficient hydraulic efficiency, uncontrolled handling under water as well as lack in accuracy in starting and closing the suspended sediment sampling, the well-established extracting of water samples by hand (dip or grab sample) lacks reproducibility. Due to these shortcomings a novel measuring device has been developed for suspended sediment sampling in rivers. For the design of the presented sampler the experiences of previous technical concepts of direct suspended sediment sampling in rivers have been considered. The sampling device consists of 2 tubes: a filling pipe (8x1 mm = 6 mm inner diameter) and an exhaust pipe (6x1 mm = 4 mm inner diameter). The filling pipe is equipped thread (M8x1 mm) to attach the "measuring nozzle" made of brass. We compared three different nozzles (D4, D5, D6) in order to investigate possible effects of different filling times. Both tubes are connected (TIG -Tungsten Inert-Gaswelding) by a flat steel. All parts (despite the nozzles) are made from stainless steel. On the tubes a plastic screw cap is mounted which allows to attach (and quickly change) standard sampling bottles. A mount enables that the device can be attached to a commercially available "GARDENA aluminium handle", thus using this rod samples can be taken at certain localities. The measurement device has been designed to improve the accuracy of suspended sediment sampling in rivers. The target was to achieve an optimum in hydraulic efficiency without disturbing the natural transport dynamics. Thus, the water sample gained from this sampling device supports the calibration and validation of indirect suspended sediment sampling devices (e.g. SSC sensor). We present the design of the sampler as well as field data in comparison with conventional dip samples.
A new suturing instrument that allows the use of microsuture at laparoscopy.
McComb, P F
1992-04-01
A surgeon at University Hospital-Shaughnessy Site in Vancouver, British Columbia in Canada has used a new suturing instrument that enters the peritoneal cavity to permit microsutures of size 6-0 or less and 75 cm in length during laparoscopy. Surgeons can use this instrument to perform female sterilizations as well as removal of the gall gladder and appendix and repair of the bowel, bladder, and ureteric injuries. As of April 1992, the suturing instrument was not yet commercially available. It consists of a partial hollow 30 cm x 2 mm (inside diameter) tube with the end that does not enter the peritoneal cavity being occluded. The suturing instrument enters the peritoneal cavity via a standard 5 mm deflection valved trocar sleeve with a 3 mm reduction sleeve or with a 3 mm inside diameter occlusive rubber washer instead of the standard 5 mm washer. The suture must have sufficient tensile strength and have low coefficients for static and for sliding surface frictions. Once the suture and needle are inside the body, forceps which have entered via another cannula detach them from the suturing instrument. A 3 mm laproscopic needle driver replaces the suturing instrument at this point. The surgeon guides the needle through the intended tissues and then withdrawn with the needle driver through the 5 mm sleeve. The surgeon ties the knot outside the body and slides it down the length of the suture to apply it to the tissue. He/she repeats this 1 more time. Scissors inserted through the other opening then cut the suture. Once mastered, this process takes only a few minutes to complete. In all 11 cases or restoration of uterine tube patency done by the surgeon in Vancouver using the new technique, tubal patency has not been hindered. 2 assessed sterilization reversals have been successful.
Variation of the pressure limits of flame propagation with tube diameter for propane-air mixtures
NASA Technical Reports Server (NTRS)
Belles, Frank E; Simon, Dorothy M
1951-01-01
An investigation was made of the variation of the pressure limits of flame propagation with tube diameter for quiescent propane with tube diameter for quiescent propane-air mixtures. Pressure limits were measured in glass tubes of six different inside diameters, with a precise apparatus. Critical diameters for flame propagation were calculated and the effect of pressure was determined. The critical diameters depended on the pressure to the -0.97 power for stoichiometric mixtures. The pressure dependence decreased with decreasing propane concentration. Critical diameters were related to quenching distance, flame speeds, and minimum ignition energy.
Smith, Simeon L.; Titze, Ingo R.
2016-01-01
Objectives To characterize the pressure-flow relationship of tubes used for semi-occluded vocal tract voice training/therapy, as well as to answer these major questions: (1) What is the relative importance of tube length to tube diameter? (2) What is the range of oral pressures achieved with tubes at phonation flow rates? (3) Does mouth configuration behind the tubes matter? Methods Plastic tubes of various diameters and lengths were mounted in line with an upstream pipe, and the pressure drop across each tube was measured at stepwise increments in flow rate. Basic flow theory and modified flow theory equations were used to describe the pressure-flow relationship of the tubes based on diameter and length. Additionally, the upstream pipe diameter was varied to explore how mouth shape affects tube resistance. Results The modified equation provided an excellent prediction of the pressure-flow relationship across all tube sizes (6% error compared to the experimental data). Variation in upstream pipe diameter yielded up to 10% deviation in pressure for tube sizes typically used in voice training/therapy. Conclusions Using the presented equations, resistance can be characterized for any tube based on diameter, length, and flow rate. With regard to the original questions, we found that: (1) For commonly used tubes, diameter is the critical variable for governing flow resistance; (2) For phonation flow rates, a range of tube dimensions produced pressures between 0 and 7.0 kPa; (3) The mouth pressure behind the lips will vary slightly with different mouth shapes, but this effect can be considered relatively insignificant. PMID:27133001
Comparative in vitro flow study of 3 different Ex-PRESS miniature glaucoma device models.
Estermann, Stephan; Yuttitham, Kanokwan; Chen, Julie A; Lee, On-Tat; Stamper, Robert L
2013-03-01
To determine the flow characteristics of the 3 different models of the Ex-PRESS miniature glaucoma device in a controlled laboratory study. The 3 different Ex-PRESS models (P-50, R-50, and P-200; Optonol Ltd; now Alcon Lab) were tested using a gravity-driven flow test. Three samples of each of the 3 Ex-PRESS models were subjected to a constant gravitational force of fluid at 5 different pressure levels (5 to 25 mm Hg). Four measurements per sample were taken at each pressure level. The main outcome measure was flow rate (Q) (µL/min). Resistance (R) was calculated by dividing pressure (P) by the measured flow (Q). The flow rate was primarily pressure dependent. The P-200 model (internal diameter 200 µm) showed a statistically significant higher flow rate and lower resistance compared with both the P-50 and R-50 models (internal diameter 50 µm) (P<0.0001). The P-50 and R-50 models demonstrated similar flow rates (P=0.08) despite their difference in tube length (2.64 vs. 2.94 mm). The 3 models of the Ex-PRESS mini shunt behaved in vitro as simple flow resistors by creating a relatively constant resistance to flow. Tube diameter was the only parameter with significant impact on flow and resistance. All models demonstrated flow rates per unit of pressure much higher than the outflow facility of a healthy human eye.
NASA Technical Reports Server (NTRS)
Myrick, Thomas M. (Inventor)
2003-01-01
A mechanism for breaking off and retaining a core sample of a drill drilled into a ground substrate has an outer drill tube and an inner core break-off tube sleeved inside the drill tube. The break-off tube breaks off and retains the core sample by a varying geometric relationship of inner and outer diameters with the drill tube. The inside diameter (ID) of the drill tube is offset by a given amount with respect to its outer diameter (OD). Similarly, the outside diameter (OD) of the break-off tube is offset by the same amount with respect to its inner diameter (ID). When the break-off tube and drill tube are in one rotational alignment, the two offsets cancel each other such that the drill can operate the two tubes together in alignment with the drill axis. When the tubes are rotated 180 degrees to another positional alignment, the two offsets add together causing the core sample in the break-off tube to be displaced from the drill axis and applying shear forces to break off the core sample.
Nicolas, M; Malvé, M; Peña, E; Martínez, M A; Leask, R
2015-02-05
In this study, the trapping ability of the Günther Tulip and Celect inferior vena cava filters was evaluated. Thrombus capture rates of the filters were tested in vitro in horizontal position with thrombus diameters of 3 and 6mm and tube diameter of 19mm. The filters were tested in centered and tilted positions. Sets of 30 clots were injected into the model and the same process was repeated 20 times for each different condition simulated. Pressure drop experienced along the system was also measured and the percentage of clots captured was recorded. The Günther Tulip filter showed superiority in all cases, trapping almost 100% of 6mm clots both in an eccentric and tilted position and trapping 81.7% of the 3mm clots in a centered position and 69.3% in a maximum tilted position. The efficiency of all filters tested decreased as the size of the embolus decreased and as the filter was tilted. The injection of 6 clots raised the pressure drop to 4.1mmHg, which is a reasonable value that does not cause the obstruction of blood flow through the system. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Alario, J.
1979-01-01
Re-entrant groove technology was extended to hydrogen heat pipes. Parametric analyses are presented which optimize the theoretical design while considering the limitations of state-of-the-art extrusion technology. The 6063-T6 aluminum extrusion is 14.6 mm OD with a wall thickness of 1.66 mm and contains 20 axial grooves which surround a central 9.3 mm diameter vapor core. Each axial groove is 0.775 mm diameter with a 0.33 mm opening. An excess vapor reservoir is provided at the evaporator to minimize the pressure containment hazard during ambient storage. Modifications to the basic re-entrant groove profile resulted in improved overall performance. While the maximum heat transport capacity decreased slightly to 103 w-m the static wicking height increased markedly to 4.5 cm. The heat pipe became operational between 20 and 30 K after a cooldown from 77 K without any difficulty. Steady state performance data taken over a 19 to 23 K temperature range indicated: (1) maximum heat transport capacity of 5.4 w-m; (2) static wicking height of 1.42 cm; and (3) overall heat pipe conductance of 1.7 watts/deg C.
A simple customized surgical guide for orthodontic miniplates with tube.
Paek, Janghyun; Su, Ming-Jeaun; Kwon, Soon-Yong; Kim, Seong-Hun; Chung, Kyu-Rhim; Nelson, Gerald
2012-09-01
This article reports the use of a customized surgical guide for simple and precise C-tube plate placement with minimized incision. Patients who were planning to have orthodontic miniplate treatment because of narrow interradicular space were recruited for this study. A combined silicone and stainless steel wire surgical guide for the C-tube was fabricated on the cast model. The taller wire of the positioning guide is used to accurately start the incision. The incision guide-wire position is verified by placing the miniplate on the coronal horizontal wire to confirm that the incision will coordinate with the screw holes. Because the miniplate is firmly held in place, there is no risk of the miniplate anchoring screws (diameter, 1.5 mm; length, 4 mm) sliding on the bone surface during placement with a manual hand driver. The surgical guide was placed on the clinical site, and it allowed precise placement of the miniplate with minimum incision and preventing from slippage or path-of-insertion angulation errors that might interfere with accurate placement. Customized surgical guide enables precise planning for miniplate positions in anatomically complex sites.
The Full-Scale Prototype for the Fluorescence Detector Array of Single-Pixel Telescopes
NASA Astrophysics Data System (ADS)
Fujii, T.; Malacari, M.; Bellido, J. A.; Farmer, J.; Galimova, A.; Horvath, P.; Hrabovsky, M.; Mandat, D.; Matalon, A.; Matthews, J. N.; Merolle, M.; Ni, X.; Nozka, L.; Palatka, M.; Pech, M.; Privitera, P.; Schovanek, P.; Thomas, S. B.; Travnicek, P.
The Fluorescence detector Array of Single-pixel Telescopes (FAST) is a design concept for the next generation of ultrahigh-energy cosmic ray (UHECR) observatories, addressing the requirements for a large-area, low-cost detector suitable for measuring the properties of the highest energy cosmic rays. In the FAST design, a large field of view is covered by a few pixels at the focal plane of a mirror or Fresnel lens. Motivated by the successful detection of UHECRs using a prototype comprised of a single 200 mm photomultiplier-tube and a 1 m2 Fresnel lens system, we have developed a new "full-scale" prototype consisting of four 200 mm photomultiplier-tubes at the focus of a segmented mirror of 1.6 m in diameter. We report on the status of the full-scale prototype, including test measurements made during first light operation at the Telescope Array site in central Utah, U.S.A.
Experimental Study of a Nitrogen Natural Circulation Loop at Low Heat Flux
NASA Astrophysics Data System (ADS)
Baudouy, B.
2010-04-01
A natural convection circulation loop in liquid nitrogen, i.e. an open thermosiphon flow configuration, has been investigated experimentally near atmospheric pressure. The experiments were conducted on a 2 m high loop with a copper tube of 10 mm inner diameter uniformly heated over a length of 0.95 m. Evolution of the total mass flow rate of the loop and the pressure difference along the tube are described. We also report the boiling curves where single phase and two-phase flows are identified with increasing heat flux. We focus our heat transfer analysis on the single phase regime where mixed convection is encountered. A heat transfer coefficient correlation is proposed. We also examine the boiling incipience as a function of the tube height.
Experimental and theoretical study of horizontal tube bundle for passive condensation heat transfer
NASA Astrophysics Data System (ADS)
Song, Yong Jae
The research in this thesis supports the design of a horizontal tube bundle condenser for passive heat removal system in nuclear reactors. From nuclear power plant containment, condensation of steam from a steam/noncondensable gas occurs on the primary side and boiling occurs on the secondary side; thus, heat exchanger modeling is a challenge. For the purpose of this experimental study, a six-tube bundle is used, where the outer diameter, inner diameter, and length of each stainless steel tube measures 38.10mm (1.5 inches), 31.75mm (1.25 inches) and 3.96m (156 inches), respectively. The pitch to diameter ratio was determined based on information gathered from literature surveys, and the dimensions were determined from calculations and experimental data. The objective of the calculations, correlations, and experimental data was to obtain complete condensation within the tube bundle. Experimental conditions for the tests in this thesis work were determined from Design Basis Accident (DBA). The applications are for an actual Passive Containment Cooling Systems (PCCS) condenser under postulated accident conditions in future light water reactors. In this research, steady state and transient experiments were performed to investigate the effect of noncondensable gas on steam condensation inside and boiling outside a tube bundle heat exchanger. The condenser tube inlet steam mass flow rate varied from 18.0 to 48.0 g/s, the inlet pressure varied from 100 kPa to 400 kPa, and the inlet noncondensable gas mass fraction varied from 1% to 10%. The effect of the noncondensable gas was examined by comparing the tube centerline temperatures for various inlet and system conditions. As a result, it was determined that the noncondensable gas accumulated near the condensate film causing a decrease of mass and energy transfer. In addition, the effect of the inlet steam flow rate gas was investigated by comparing the tube centerline temperatures, the conclusion being that, as the inlet steam mass flow rate increased, the length required for complete condensation also increased. Comparison of tube centerline temperature profiles was also used to examine the effect of inlet pressure on the heat transfer performance. From this assessment, it was determined that as the inlet pressure increased, the length required for complete condensation decreased. The investigation of tube bundle effects was conducted by comparing the condensate flow rates. The experimental results showed that the upper tubes in the bundle had better heat transfer performance than the lower tubes. In regard to modeling of the heat exchanger in this study, for the primary side, an empirical correlation was developed herein to provide Nusselt numbers for condensation heat transfer in horizontal tubes with noncondensable gases. Nusselt numbers were correlated as: Nu = 106.31·Re m0.147·W a-0.843. The empirical model for condensation heat transfer coefficients and the secondary-side model were integrated within a Matlab program to provide an analysis tool for horizontal tube bundle condenser heat exchangers. Also on the secondary side, two phase heat transfer coefficients were modeled considering both convective boiling and nucleate boiling as: hTP = 10.03·exp(-2.28·alpha)· hCV + 0.076·exp[3.73x10-6·(Re f-1.6x105)]·hNB.
Cockburn, J F; Maddern, G J; Wemyss-Holden, S A
2007-03-01
To examine the effect of applying increasing amounts of direct current (DC) before and during alternating current radiofrequency ablation of porcine liver. Using a Radiotherapeutics RF3000 generator, a 9 V AC/DC transformer and a 16 G plain aluminium tube as an electrode, a control group of 24 porcine hepatic radiofrequency ablation zones was compared with 24 zones created using a bimodal electric tissue ablation (BETA) technique in three pigs. All ablations were terminated when tissue impedance rose to greater than 999 Omega or radiofrequency energy input fell below 5 W on three successive measurements taken at 1 min intervals. BETA ablations were performed in two phases: an initial phase of variable duration DC followed by a second phase during which standard radiofrequency ablation was applied simultaneously with DC. During this second phase, radiofrequency power input was regulated by the feedback circuitry of the RF3000 generator according to changes in tissue impedance. The diameters (mm) of each ablation zone were measured by two observers in two planes perpendicular to the plane of needle insertion. The mean short axis diameter of each ablation zone was subjected to statistical analysis. With increased duration of prior application of DC, there was a progressive increase in the diameter of the ablation zone (p<0.001). This effect increased sharply up to 300 s of pre-treatment after which a further increase in diameter occurred, but at a much lesser rate. A maximum ablation zone diameter of 32 mm was produced (control diameters 10-13 mm). Applying a 9 V DC to porcine liver in vivo, and continuing this DC application during subsequent radiofrequency ablation, results in larger ablation zone diameters compared with radiofrequency ablation alone.
a Study of a High Frequency Miniature Reservoir-Less Pulse Tube
NASA Astrophysics Data System (ADS)
Garaway, I.; Grossman, G.
2008-03-01
A miniature high frequency reservoir-less pulse tube cryocooler has been designed and tested in our laboratory. The cryocooler having a regenerator length of 12.0 mm and an overall volume of 2.3cc (excluding the compressor) reached a low temperature of 146K and provided 100mW of cooling at 160K. This experimental study shows that it is possible to miniaturize a pulse tube cryocooler to very short regenerator lengths by implementing a few basic principles: Most importantly, high operating frequencies at small tidal displacements, a regenerator matrix with small hydraulic diameters, and increased helium fill pressures. This study also shows that as the operating frequency of a miniature cryocooler increases, the reservoir becomes less necessary as a phase shifting device. At higher frequencies and appropriate inertance tube geometries, the impedance and capacitance of the inertance tube itself takes over the phase shifting task. An outline of the design and modeling principles is presented along with some details of the experimental apparatus and testing procedures.
Heat Transfer at a Long Electrically-Simulated Water Wall in a Circulating Fluidised Bed
NASA Astrophysics Data System (ADS)
Sundaresan, R.; Kolar, Ajit Kumar
In the present work, heat transfer measurements are reported in a 100mm square, 5.5 m tall, cold CFB. The test section is a 19 mm OD electrically heated heat transfer tube, 4.64 m tall (covering more than 80% of the CFB height), sandwiched between two equally tall dummy tubes of 19mm OD, thus simulating a water wall geometry, forming one wall of the CFB. Narrow cut sand particles of mean diameters 156, 256, and 362 micrometers, and a wide cut sample of mean diameter 265 micrometer were used as the bed material. The superficial gas velocity ranged from 4.2 to 8.2 m/s, and the solids recycle flux varied from 17 to 110 kg/m2s. Local heat transfer coefficient at the simulated water wall varies, as expected from a low value at the top of the riser to a high value at the bottom, with an interesting increasing and decreasing trend in between. The average heat transfer coefficients were compared with those available in open literature. Correlations for average heat transfer coefficient are presented, both in terms of an average suspension density and also in terms of important nondimensional numbers, namely, Froude number, relative solids flux and velocity ratio. Comparisons are also made with predictions of relevant heat transfer models. Based on the present fifty-five experimental data points, the following correlation was presented with a correlation coefficient of 0.862 and maximum error is ± 15 %.
Holmium: YAG laser-induced liquid jet knife: possible novel method for dissection.
Nakagawa, Atsuhiro; Hirano, Takayuki; Komatsu, Makoto; Sato, Mariko; Uenohara, Hiroshi; Ohyama, Hideki; Kusaka, Yasuko; Shirane, Reizo; Takayama, Kazuyoshi; Yoshimoto, Takashi
2002-01-01
Making surgical incisions in vessel-rich organs without causing bleeding is difficult. Thus, it is necessary to develop new devices for this purpose, especially for surgery involving small vessels as in neurosurgery, where damage against even small cerebral vessels result in severe neurological deficits. A laser-induced liquid jet was generated by irradiating pulsed Holmium Yttrium-Aluminum-Garnet (Ho: YAG) laser (beams of 350 microseconds pulse width) within a copper tube (internal diameter, 1 mm) with pure water (150 ml /hour). Ho: YAG laser beams were irradiated through an optical fiber (core diameter, 0.4 mm). The influence of the input of laser energy, structure of the nozzle, and the stand-off distance between the optical fiber tip and nozzle exit on the jet velocity was measured by a high-speed video camera to evaluate controllability of jet. The effect on artificial organs made of 10 and 30%(w/v) gelatin, each of which represent features of soft tissue and blood vessels. Jet velocity increased in proportion to gain in laser energy input, and maximum penetration depth into 10%(w/v) gelatin was 35 mm by single exposure at 350 mJ/pulse without impairing a vessel model. Shapes of nozzle also modified jet velocity with optimal nozzle/tube area ratio of 0.25. The laser-induced liquid jet has excellent potential as a new tool for removing soft tissue without damaging vital structures. Copyright 2002 Wiley-Liss, Inc.
High-intensity focused ultrasound ablation around the tubing
Siu, Jun Yang; Liu, Chenhui
2017-01-01
High-intensity focused ultrasound (HIFU) has been emerging as an effective and noninvasive modality in cancer treatment with very promising clinical results. However, a small vessel in the focal region could be ruptured, which is an important concern for the safety of HIFU ablation. In this study, lesion formation in the polyacrylamide gel phantom embedded with different tubing (inner diameters of 0.76 mm and 3 mm) at varied flow speeds (17–339 cm/s) by HIFU ablation was photographically recorded. Produced lesions have decreased length (~30%) but slightly increased width (~6%) in comparison to that without the embedded tubing. Meanwhile, bubble activities during the exposures were measured by passive cavitation detection (PCD) at the varied pulse repetition frequency (PRF, 10–30 Hz) and duty cycle (DC, 10%-20%) of the HIFU bursts. High DC and low flow speed were found to produce stronger bubble cavitation whereas no significant influence of the PRF. In addition, high-speed photography illustrated that the rupture of tubing was produced consistently after the first HIFU burst within 20 ms and then multiple bubbles would penetrate into the intraluminal space of tubing through the rupture site by the acoustic radiation force. Alignment of HIFU focus to the anterior surface, middle, and posterior surface of tubing led to different characteristics of vessel rupture and bubble introduction. In summary, HIFU-induced vessel rupture is possible as shown in this phantom study; produced lesion sizes and shapes are dependent on the focus alignment to the tubing, flow speed, and tubing properties; and bubble cavitation and the formation liquid jet may be one of the major mechanisms of tubing rupture as shown in the high-speed photography. PMID:29161293
High-intensity focused ultrasound ablation around the tubing.
Siu, Jun Yang; Liu, Chenhui; Zhou, Yufeng
2017-01-01
High-intensity focused ultrasound (HIFU) has been emerging as an effective and noninvasive modality in cancer treatment with very promising clinical results. However, a small vessel in the focal region could be ruptured, which is an important concern for the safety of HIFU ablation. In this study, lesion formation in the polyacrylamide gel phantom embedded with different tubing (inner diameters of 0.76 mm and 3 mm) at varied flow speeds (17-339 cm/s) by HIFU ablation was photographically recorded. Produced lesions have decreased length (~30%) but slightly increased width (~6%) in comparison to that without the embedded tubing. Meanwhile, bubble activities during the exposures were measured by passive cavitation detection (PCD) at the varied pulse repetition frequency (PRF, 10-30 Hz) and duty cycle (DC, 10%-20%) of the HIFU bursts. High DC and low flow speed were found to produce stronger bubble cavitation whereas no significant influence of the PRF. In addition, high-speed photography illustrated that the rupture of tubing was produced consistently after the first HIFU burst within 20 ms and then multiple bubbles would penetrate into the intraluminal space of tubing through the rupture site by the acoustic radiation force. Alignment of HIFU focus to the anterior surface, middle, and posterior surface of tubing led to different characteristics of vessel rupture and bubble introduction. In summary, HIFU-induced vessel rupture is possible as shown in this phantom study; produced lesion sizes and shapes are dependent on the focus alignment to the tubing, flow speed, and tubing properties; and bubble cavitation and the formation liquid jet may be one of the major mechanisms of tubing rupture as shown in the high-speed photography.
Zhang, Shu-xin; Huang, Fengfa; Gates, Mary; White, Jason; Holmberg, Eric G
2010-08-30
Intrathecal infusion has been widely used to directly deliver drugs or neurotrophins to a lesion site following spinal cord injury. Evidence shows that intrathecal infusion is efficient for 7 days but is markedly reduced after 14 days, due to time dependent occlusion. In addition, extensive fibrotic scarring is commonly observed with intrathecal infusion. These anomalies need to be clearly elucidated in histology. In the present study, all adult Long-Evans rats received a 25 mm contusion injury on spinal cord T10 produced using the NYU impactor device. Immediately after injury, catheter tubing with an outer diameter of 0.38 mm was inserted through a small dural opening at L3 into the subdural space with the tubing tip positioned near the injury site. The tubing was connected to an Alzet mini pump, which was filled with saline solution and was placed subcutaneously. Injured rats without tubing served as control. Rats were behaviorally tested for 6 weeks using the BBB locomotor rating scale and histologically assessed for tissue scarring. Six weeks later, we found that the intrathecal tubing caused extensive scarring and inflammation, related to neutrophils, macrophages and plasma cells. The tubing's tip was occluded by scar tissue and inflammatory cells. The scar tissue surrounding the tubing consists of 20-70 layers of fibroblasts and densely compacted collagen fibers, seriously compressing and damaging the cord tissue. BBB scores of rats with intrathecal tubing were significantly lower than control rats (p<0.01) from 2 weeks after injury, implying serious impairment of functional recovery caused by the scarring. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Extrusion of small-diameter, thin-wall tungsten tubing
NASA Technical Reports Server (NTRS)
Blankenship, C. P.; Gyorgak, C. A.
1967-01-01
Small-diameter, thin-wall seamless tubing of tungsten has been fabricated in lengths of up to 10 feet by hot extrusion over a floating mandrel. Extrusion of 0.50-inch-diameter tubing over 0.4-inch-diameter mandrels was accomplished at temperatures ranging from 3000 degrees to 4000 degrees F.
NASA Technical Reports Server (NTRS)
Redding, Chip
2002-01-01
As an alternative to conventional tubing instrumentation for measuring airflow, designers and technicians at the NASA Glenn Research Center have been fabricating packaging components and assembling a set of unique probes using commercial-off-the-shelf microelectromechanical systems (MEMS) integrated circuits (computer chips). Using MEMS as an alternative has some compelling advantages over standard measurement devices. Sensor technologies have matured through high-production usage in industries such as automotive and aircraft manufacturers. Currently, MEMS are the choice in applications such as tire pressure monitors, altimeters, pneumatic controls, cable leak detectors, and consumer appliances. Conventional instrumentation uses tubing buried in the model aerodynamic surfaces or wind tunnel walls. The measurements are made when pressure is introduced at the tube opening. The pressure then must travel the tubing for lengths ranging from 20 to hundreds of feet before reaching an electronic signal conditioner. This condition causes a considerable amount of damping and requires measurements to be made only after the test rig has reached steady-state operation. The electronic MEMS pressure sensor is able to take readings continuously under dynamic states in nearly real time. The use of stainless steel tubing for pressure measurements requires many tubes to be cleaned, cut to length, carefully installed, and delicately deburred and spliced for use. A cluster of a few hundred 1/16-in.- (0.0625-in.-) diameter tubes (not uncommon in research testing facilities) can be several inches in diameter and may weigh enough to require two men to handle. Replacing hard tubing with electronic chips can eliminate much of the bulk. Each sensor would fit on the tip of the 1/16-in. tubing with room to spare. The P592 piezoresistive silicon pressure sensor (Lucas NovaSensor, Fremont, CA) was chosen for this project because of its cost, availability, and tolerance to extreme ambient conditions. The chip is 1 mm square by 0.6 mm thick (0.039 by 0.023 in.) with 0.12-mm (0.005-in.) wire connection tabs. Three MEMS chips were used to build the first type of flow-angularity probe. This MEMS probe will be demonstrated as an alternative to a standard tube type "Cobra Probe" now used routinely in wind tunnel and aeronautical hardware applications. The response time and accuracy would allow the probe to be translated on an actuator across a flow field, yielding precision dynamic measurements not possible with conventional instrumentation. The low profile, the minimal power requirement, the rugged construction, and the moderate cost all contribute to making MEMS sensors the enticing choice instrument in future research measurement needs. The MEMS probe efforts are a continuation of work initiated by Brian Willis, without whose foresight and efforts this project would never have been realized. This task was funded through cooperation with the NASA Electronic Parts and Packaging (NEPP) program at the Jet Propulsion Laboratory.
NASA Astrophysics Data System (ADS)
Rahman, Md. Lutfor; Nourin, Farah Nazifa; Salsabil, Zaimaa; Yasmin, Nusrat; Ali, Mohammad
2016-07-01
Thermal control is an important topic for thermal management of small electrical and electronic devices. Closed loop pulsating heat pipe (CLPHP) arises as the best solution for thermal control. The aim of this experimental study is to search a CLPHP of better thermal performance for cooling different electrical and electronic devices. In this experiment, methanol is used as working fluid. The effect of using methanol as a working fluid is studied on thermal performance in different filling ratios and angles of inclination. A copper capillary tube is used where the inner diameter is 2mm,outer diameter is 2.5mm and 250mm long. The CLPHP has 8 loops where the evaporation section is 50mm, adiabatic section is 120mm and condensation section is 80mm. The experiment is done using FR of 40%-70% with 10% of interval and angles of inclination 0° (vertical), 30°, 45°, 60° varying heat input. The results are compared on the basis of evaporator temperature, condenser temperature and their differences, thermal resistance, heat transfer co-efficient, power input and pulsating time. The results demonstrate the effect of methanol in different filling ratios and angles of inclination. M ethanol shows better performance at 30° inclination with 40% FR.
Effects of regenerator geometry on pulse tube refrigerator performance
NASA Technical Reports Server (NTRS)
Lewis, M.; Kuriyama, T.; Xiao, J. H.; Radebaugh, R.
1998-01-01
This paper gives results of the cooling performance of a double-inlet pulse tube refrigerator using various regenerators. The same pulse tube was used for all the experiments and measured 4.76 mm in diameter and 46.2 mm in length. A commercial linear compressor with a swept volume of 4 cm3 was used in these experiments. The operating conditions were held constant at a mean pressure of 2.0 MPa and a frequency of 54 Hz. Using finite difference software called REGEN3.1, developed at NIST, and recent experiment results, we optimized a series of regenerators based on dimensions, materials and screen packing. The values used for calculating the thermal conduction through stacked screens by REGEN3.1 were based on recent experimental results from NIST. The regenerator tubes were designed using 316 stainless steel and titanium materials. The regenerator matrices investigated were 400-mesh and 500-mesh stainless steel screen. The valve settings for both orifices were adjusted to minimize the no-load temperature for all regenerators. A cooling capacity curve from 0 to 3 W was also determined. The performance of the pulse tube refrigerator using the different regenerators is discussed. The experimental results from the various regenerators are evaluated and compared with their corresponding numerically calculated coefficient of performance (COP) and regenerator design as determined by REGEN3.1.
Visualization and flow boiling heat transfer of hydrocarbons in a horizontal tube
NASA Astrophysics Data System (ADS)
Yang, Zhuqiang; Bi, Qincheng; Guo, Yong; Liu, Zhaohui; Yan, Jianguo
2013-07-01
Visualizations of a specific hydrocarbon fuel in a horizontal tube with 2.0 mm inside diameter were investigated. The experiments were conducted at mass velocity of 213.4, 426.5 and 640.2 kg/ (m2ṡs), diabatic lengths of 140, 240 and 420 mm under the pressure from 2.0-2.7 MPa. In the sub-pressure conditions, bubbly, intermittent, stratified-wave, churn and annular flow patterns were observed. The frictional pressure drops were also measured to distinguish the patterns. The development of flow patterns and frictional pressure drop were positively related to the mass velocity and the heat flux. However, the diabatic length of the tube takes an important part in the process. The residence time of the fluid does not only affect the transition of the patterns but influence the composition of the fuel manifested by the fuel color and carbon deposit. The special observational phenomenon was obtained for the supercritical pressure fluid. The flow in the tube became fuzzier and pressure drop changed sharply near the pseudocritical point. The flow boiling heat transfer characteristics of the hydrocarbons were also discussed respectively. The curve of critical heat flux about onset of nucleate boiling was plotted with different mass velocities and diabatic tube lengths. And heat transfer characteristics of supercritical fuel were proved to be better than that in subcritical conditions.
Confocal microlaparoscope for imaging the fallopian tube
NASA Astrophysics Data System (ADS)
Wu, Tzu-Yu; Schafer, Rachel; Rouse, Andrew R.; Gmitro, Arthur F.
2012-02-01
Recent evidence suggests that epithelial ovarian cancer may originate in the fimbriated end of the fallopian tube1. Unlike many other cancers, poor access to the ovary and fallopian tubes has limited the ability to study the progression of this deadly disease and to diagnosis it during the early stage when it is most amenable to therapy. We have previously reported on a rigid confocal microlaparoscope system that is currently undergoing a clinical trial to image the epithelial surface of the ovary2. In order to gain in vivo access to the fallopian tubes we have developed a new confocal microlaparoscope with an articulating distal tip. The new instrument builds upon the technology developed for the existing confocal microlaparoscope. It has an ergonomic handle fabricated by a rapid prototyping printer. While maintaining compatibility with a 5 mm trocar, the articulating distal tip of the instrument consists of a 2.2 mm diameter bare fiber bundle catheter with automated dye delivery for fluorescence imaging. This small and flexible catheter design should enable the confocal microlaparoscope to image early stage ovarian cancer arising inside the fallopian tube. Early ex vivo mages of human fallopian tube and in vivo imaging results from recent open surgeries using the rigid confocal microlaparoscope system are presented. Ex vivo images from animal models using the new articulating bare fiber system are also presented. These high quality images collected by the new flexible system are similar in quality to those obtained from the epithelial surface of ovaries with the rigid clinical confocal microlaparoscope.
Field and Numerical Study on Natural River Mixing
2011-06-01
transport of larvae from spawning to rearing habitats , or to mitigate potentially harmful human and environmental effects from wastewater discharges or...fluorescent dye was released for approximately one-hour through an 8mm diameter tube located 0.05 m below the waterline through a butterfly valve that was...multidimensional flow model for the white sturgeon critical- habitat reach, Kootenai River near Bonners Ferry, Idaho. U.S. Geological Survey Scientific
NASA Astrophysics Data System (ADS)
Nagib, Hassan; Vinuesa, Ricardo
2013-11-01
Ability of available Pitot tube corrections to provide accurate mean velocity profiles in ZPG boundary layers is re-examined following the recent work by Bailey et al. Measurements by Bailey et al., carried out with probes of diameters ranging from 0.2 to 1.89 mm, together with new data taken with larger diameters up to 12.82 mm, show deviations with respect to available high-quality datasets and hot-wire measurements in the same Reynolds number range. These deviations are significant in the buffer region around y+ = 30 - 40 , and lead to disagreement in the von Kármán coefficient κ extracted from profiles. New forms for shear, near-wall and turbulence corrections are proposed, highlighting the importance of the latest one. Improved agreement in mean velocity profiles is obtained with new forms, where shear and near-wall corrections contribute with around 85%, and remaining 15% of the total correction comes from turbulence correction. Finally, available algorithms to correct wall position in profile measurements of wall-bounded flows are tested, using as benchmark the corrected Pitot measurements with artificially simulated probe shifts and blockage effects. We develop a new scheme, κB - Musker, which is able to accurately locate wall position.
Temporary Rectal Stenting for Management of Severe Perineal Wounds in Two Dogs.
Skinner, Owen T; Cuddy, Laura C; Coisman, James G; Covey, Jennifer L; Ellison, Gary W
Perineal wounds in dogs present a challenge due to limited local availability of skin for closure and constant exposure to fecal contaminants. This report describes temporary rectal stenting in two dogs following severe perineal wounds. Dog 1 presented with a 4 × 4 cm full-thickness perineal slough secondary to multiple rectal perforations. A 12 mm internal diameter endotracheal tube was placed per-rectum as a temporary stent to minimize fecal contamination. The stent was removed 18 days after placement, and the perineal wound had healed at 32 days post-stent placement, when a minor rectal stricture associated with mild, intermittent tenesmus was detected. Long-term outcome was deemed good. Dog 2 presented with multiple necrotic wounds with myiasis, circumferentially surrounding the anus and extending along the tail. A 14 mm internal diameter endotracheal tube was placed per-rectum. The perineal and tail wounds were managed with surgical debridement and wet-to-dry and honey dressings prior to caudectomy and negative pressure wound therapy (NPWT). Delayed secondary wound closure and stent removal were performed on day six without complication. Long-term outcome was deemed excellent. Temporary rectal stenting may be a useful technique for fecal diversion to facilitate resolution of complex perineal injuries, including rectal perforation.
Mortelliti, Caroline L; Mortelliti, Anthony J
2016-08-01
To elucidate the relatively large incremental percent change (IPC) in cross sectional area (CSA) in currently available small endotracheal tubes (ETTs), and to make recommendation for lesser incremental change in CSA in these smaller ETTs, in order to minimize iatrogenic airway injury. The CSAs of a commercially available line of ETTs were calculated, and the IPC of the CSA between consecutive size ETTs was calculated and graphed. The average IPC in CSA with large ETTs was applied to calculate identical IPC in the CSA for a theoretical, smaller ETT series, and the dimensions of a new theoretical series of proposed small ETTs were defined. The IPC of CSA in the larger (5.0-8.0 mm inner diameter (ID)) ETTs was 17.07%, and the IPC of CSA in the smaller ETTs (2.0-4.0 mm ID) is remarkably larger (38.08%). Applying the relatively smaller IPC of CSA from larger ETTs to a theoretical sequence of small ETTs, starting with the 2.5 mm ID ETT, suggests that intermediate sizes of small ETTs (ID 2.745 mm, 3.254 mm, and 3.859 mm) should exist. We recommend manufacturers produce additional small ETT size options at the intuitive intermediate sizes of 2.75 mm, 3.25 mm, and 3.75 mm ID in order to improve airway management for infants and small children. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Compliance effects on small diameter polyurethane graft patency.
Uchida, N; Kambic, H; Emoto, H; Chen, J F; Hsu, S; Murabayshi, S; Harasaki, H; Nosé, Y
1993-10-01
Microporous compliance matched and noncompliant grafts were compared in a dog carotid artery interposition model. We fabricated 4 mm diameter sponge type polyurethane (Biomer) tubes 5 cm in length with a 0.5 mm wall thickness. The luminal surface was covered with a 50 microns coating of cross-linked gelatin. Compliance was measured in vitro and in vivo by volume and vessel diameter changes. Over a mean arterial pressure range of 55-155 mm Hg, the diameter changes of grafts and stump arteries were measured in situ using an ultrasonic Hokanson device. Compliance matched grafts were found to have the same in vitro compliance values as the natural canine carotid at a mean arterial pressure of 100 mm Hg. Compliance matched and noncompliant grafts had values of 10.3 +/- 1.3 and 0.9 +/- 0.1 x 10(-2) mm Hg, respectively. End to end arterial anastomoses were constructed between the graft and the host arteries. The use of synthetic grafts with matched compliance to the adjacent natural vessels has been advocated as the ideal solution to circumvent the problems of graft failure. These studies indicate that compliance values for compliance matched grafts decreased immediately after implantation (from 10.3 to 6.5 x 10(-2) %/mm Hg) and within 6 weeks decreased to 3.6 x 10(-2) %/mm Hg. The compliance values for noncompliant grafts remained constant throughout the test period. At autopsy all grafts showed a tightly adhered tissue capsule. The thickness of the anastomotic hyperplasia at the distal sites of compliance matched grafts was significantly different (P < .05) than that of the adjacent artery. The patency for compliant and noncompliant grafts was 64% and 50%, respectively. Evidence for polyurethane graft degradation was obtained by Fourier transform infrared spectroscopy and gel permeation chromatography analysis of patent explants. Compliance mismatch alone does not contribute to graft failure, however, material degradation, suture technique and/or capsule formation can play a contributory role although these were not tested directly.
Time-Resolved Rayleigh Scattering Measurements in Hot Gas Flows
NASA Technical Reports Server (NTRS)
Mielke, Amy F.; Elam, Kristie A.; Sung, Chih-Jen
2008-01-01
A molecular Rayleigh scattering technique is developed to measure time-resolved gas velocity, temperature, and density in unseeded gas flows at sampling rates up to 32 kHz. A high power continuous-wave laser beam is focused at a point in an air flow field and Rayleigh scattered light is collected and fiber-optically transmitted to the spectral analysis and detection equipment. The spectrum of the light, which contains information about the temperature and velocity of the flow, is analyzed using a Fabry-Perot interferometer. Photomultipler tubes operated in the photon counting mode allow high frequency sampling of the circular interference pattern to provide time-resolved flow property measurements. Mean and rms velocity and temperature fluctuation measurements in both an electrically-heated jet facility with a 10-mm diameter nozzle and also in a hydrogen-combustor heated jet facility with a 50.8-mm diameter nozzle at NASA Glenn Research Center are presented.
Laser myringotomy with the CO2 Otoscan laser
NASA Astrophysics Data System (ADS)
Sedlmaier, Benedikt W.; Jivanjee, Antonio; Schoenfeld, Uwe; Jovanovic, Sergije
2000-06-01
Tympanic ventilation is the treatment of choice for otitis media with effusion (OME). CO2 laser myringotomy has already proven its value and is finding increasing clinical application. The ventilation time in the middle ear is essentially determined by the size of the laser perforation. Perforations exceeding 2 mm in diameter enable tympanic ventilation for about three weeks and thus compete with the ventilation tube in the treatment of OME. IN a prospective study, laser myringotomy is performed in 84 children with OME with the new CO2 laser otoscope Otoscan. The closure time was 17 days in average for a preformation diameter of 2 mm. In the further clinical course, the ear-drums healed without atrophic scar formation. In an observation period of six month the recurrency rate of effusion was approximately 10 percent. Laser myringotomy seems to be an useful method in the operative therapy of secretory otitis media.
NASA Astrophysics Data System (ADS)
Fukunari, Masafumi; Yamaguchi, Toshikazu; Nakamura, Yusuke; Komurasaki, Kimiya; Oda, Yasuhisa; Kajiwara, Ken; Takahashi, Koji; Sakamoto, Keishi
2018-04-01
Experiments using a 1 MW-class gyrotron were conducted to examine a beamed energy propulsion rocket, a microwave rocket with a beam concentrator for long-distance wireless power feeding. The incident beam is transmitted from a beam transmission mirror system. The beam transmission mirror system expands the incident beam diameter to 240 mm to extend the Rayleigh length. The beam concentrator receives the beam and guides it into a 56-mm-diameter cylindrical thruster tube. Plasma ignition and ionization front propagation in the thruster were observed through an acrylic window using a fast-framing camera. Atmospheric air was used as a propellant. Thrust generation was achieved with the beam concentrator. The maximum thrust impulse was estimated as 71 mN s/pulse from a pressure history at the thrust wall at the input energy of 638 J/pulse. The corresponding momentum coupling coefficient, Cm was inferred as 204 N/MW.
Flow structure of natural dehumidification over a horizontal finned-tube
NASA Astrophysics Data System (ADS)
Hirbodi, Kamran; Yaghoubi, Mahmood
2016-08-01
In the present study, structure of water drops formation, growth, coalescence and departure over a horizontal finned-tube during natural dehumidification is investigated experimentally. Starting time of repelling the drops as well as heat transfer rate and the rate of dripping condensates in quasi-steady-state conditions are presented. Furthermore, cold airflow pattern around the horizontal finned-tube is visualized by using smoke generation scheme during natural dehumidification process. The finned-tube has a length of 300 mm, and inner and outer fin diameters, fin thickness and fin spacing are 25.4, 56, 0.4 and 2 mm, respectively. The tests are conducted in an insulated control room with dimensions of 5.8 m × 3 m × 4 m. Ambient air temperature, relative humidity and fin base temperature are selected from 25 to 35 °C, from 40 to 70 % and from 4 to 8 °C, respectively. Observations show that natural condensation from humid air over the test case is completely dropwise. Droplets only form on the edge of the fin and lateral fin surfaces remain almost dry. Dehumidification process over the tested finned-tube is divided into four stages; nucleation, formation, growth and departure of drops. It is also observed that the condensate inundation leaves the tube bottom in the form of droplets. Smoke visualization depicts that humid airflows downward around the cold finned-tube surface without noticeable turbulence and separation in the initial stages of dehumidification process. But the airflow has some disturbances in the intermediate stage and especially during drop departure on the edge of the fins.
Christofilos, N.C.; Polk, I.J.
1959-02-17
Improvements in linear particle accelerators are described. A drift tube system for a linear ion accelerator reduces gap capacity between adjacent drift tube ends. This is accomplished by reducing the ratio of the diameter of the drift tube to the diameter of the resonant cavity. Concentration of magnetic field intensity at the longitudinal midpoint of the external sunface of each drift tube is reduced by increasing the external drift tube diameter at the longitudinal center region.
Oscillation effects upon film boiling from a sphere.
NASA Technical Reports Server (NTRS)
Schmidt, W. E.; Witte, L. C.
1972-01-01
Heat transfer rates from a silver-plated copper sphere, 0.75 in. in diameter, were studied by high speed photography during oscillations of the sphere in saturated liquid nitrogen and Freon-11. The oscillation frequencies ranged from zero to 13 Hz, and the amplitude-to-diameter ratio varied from zero to 2.67. The sphere was supported by a thin-walled stainless steel tube and carried a thermocouple attached near the lower stagnation point. A Fastax WF-3 16mm movie camera was used at about 2000 frames/sec. The differences in the vapor removal process at lower and higher oscillation frequencies are discussed.
Experimental study of boron-coated straws with a neutron source
NASA Astrophysics Data System (ADS)
Xie, Zhaoyang; Zhou, Jianrong; Song, Yushou; Lacy, Jeffrey L.; Sun, Liang; Sun, Zhijia; Hu, Bitao; Chen, Yuanbo
2018-04-01
Multiple types of high quality neutron detectors are proposed for the first phase of the China Spallation Neutron Source (CSNS), which will be commissioned in 2018. Considering the shortage of 3He supply, a detector module composed of 49 boron-coated straws (BCS) was developed by Proportional Technologies Inc. (PTI). Each straw has a length of 1000 mm and a diameter of 7.5 mm. Seven straws are tightly packed in a tube, and seven tubes are organized in a row to form a detector module. The charge division method is used for longitudinal positioning. A specific readout system was utilized to output the signal and simultaneously encode each straw. The performance of this detector module was studied using a moderated 252Cf source at the Institute of High Energy Physics (IHEP). The signal amplitude spectrum indicates its n-gamma discrimination capability. Despite the complex readout method, a longitudinal resolution of FWHM=6.1 ± 0.5 mm was obtained. The three-dimensional positioning ability qualifies this BCS detector module as a promising detector for small angle neutron scattering.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whalen, Scott A.; Joshi, Vineet V.; Overman, Nicole R.
Shear Assisted Processing and Extrusion (ShAPE) has been scaled-up and applied to direct extrusion of thin-walled magnesium tubing. Using ShAPE, billets of ZK60A-T5 were directly extruded into round tubes having an outer diameter of 50.8 mm and wall thickness of 1.52 mm. The severe shearing conditions inherent to ShAPE resulted in microstructural refinement with an average grain size of 3.8μm measured at the midpoint of the tube wall. Tensile testing per ATSM E-8 on specimens oriented parallel to the extrusion direction gave an ultimate tensile strength of 254.4 MPa and elongation of 20.1%. Specimens tested perpendicular to the extrusion directionmore » had an ultimate tensile strength of 297.2 MPa and elongation of 25.0%. Due to material flow effects resulting from the simultaneous linear and rotational shear intrinsic to ShAPE, ram force and electrical power consumption during extrusion were just 40 kN and 11.5 kW respectively. This represents a significant reduction in ram force and power consumption compared to conventional extrusion. As such, there is potential for ShAPE to offer a scalable, lower cost extrusion option with potentially improved bulk mechanical properties.« less
NASA Astrophysics Data System (ADS)
Wohlschlögel, Markus; Steegmüller, Rainer; Schüßler, Andreas
2014-07-01
Nonmetallic inclusions in Nitinol, such as carbides (TiC) and intermetallic oxides (Ti4Ni2O x ), are known to be triggers for fatigue failure of Nitinol medical devices. These mechanically brittle inclusions are introduced during the melting process. As a result of hot and cold working in the production of Nitinol tubing inclusions are fractionalized due to the mechanical deformation imposed. While the role of inclusions regarding Nitinol fatigue performance has been studied extensively in the past, their effect on Nitinol corrosion behavior was investigated in only a limited number of studies. The focus of the present work was to understand the effect of inclusion size and distribution on the corrosion behavior of medical-device grade Nitinol tubing made from three different ingot sources during different manufacturing stages: (i) for the initial stage (hollow: round bar with centric hole), (ii) after hot drawing, and (iii) after the final drawing step (final tubing dimensions: outer diameter 0.3 mm, wall thickness 0.1 mm). For one ingot source, two different material qualities were investigated. Potentiodynamic polarization tests were performed for electropolished samples of the above-mentioned stages. Results indicate that inclusion size rather than inclusion quantity affects the susceptibility of electropolished Nitinol to pitting corrosion.
Continuous lactic acid fermentation using a plastic composite support biofilm reactor.
Cotton, J C; Pometto, A L; Gvozdenovic-Jeremic, J
2001-12-01
An immobilized-cell biofilm reactor was used for the continuous production of lactic acid by Lactobacillus casei subsp. rhamnosus (ATCC 11443). At Iowa State University, a unique plastic composite support (PCS) that stimulates biofilm formation has been developed. The optimized PCS blend for Lactobacillus contains 50% (wt/wt) agricultural products [35% (wt/wt) ground soy hulls, 5% (wt/wt) soy flour, 5% (wt/wt) yeast extract, 5% (wt/wt) dried bovine albumin, and mineral salts] and 50% (wt/wt) polypropylene (PP) produced by high-temperature extrusion. The PCS tubes have a wall thickness of 3.5 mm, outer diameter of 10.5 mm, and were cut into 10-cm lengths. Six PCS tubes, three rows of two parallel tubes, were bound in a grid fashion to the agitator shaft of a 1.2-1 vessel for a New Brunswick Bioflo 3000 fermentor. PCS stimulates biofilm formation, supplies nutrients to attached and suspended cells, and increases lactic acid production. Biofilm thickness on the PCS tubes was controlled by the agitation speed. The PCS biofilm reactor and PP control reactor achieved optimal average production rates of 9.0 and 5.8 g l(-1) h(-1), respectively, at 0.4 h(-1) dilution rate and 125-rpm agitation with yields of approximately 70%.
Concentration by centrifugation for gas exchange EPR oximetry measurements with loop-gap resonators.
Subczynski, Witold K; Felix, Christopher C; Klug, Candice S; Hyde, James S
2005-10-01
Measurement of the bimolecular collision rate between a spin label and oxygen is conveniently carried out using a gas permeable plastic sample tube of small diameter that fits a loop-gap resonator. It is often desirable to concentrate the sample by centrifugation in order to improve the signal-to-noise ratio (SNR), but the deformable nature of small plastic sample tubes presents technical problems. Solutions to these problems are described. Two geometries were considered: (i) a methylpentene polymer, TPX, from Mitsui Chemicals, at X-band and (ii) Teflon tubing with 0.075 mm wall thickness at Q-band. Sample holders were fabricated from Delrin that fit the Eppendorf microcentrifuge tubes and support the sample capillaries. For TPX, pressure of the sealant at the end of the sample tube against the Delrin sample holder provided an adequate seal. For Teflon, the holder permitted introduction of water around the tube in order to equalize pressures across the sealant during centrifugation. Typically, the SNR was improved by a factor of five to eight. Oxygen accessibility applications in site-directed spin labeling studies are discussed.
Concentration by centrifugation for gas exchange EPR oximetry measurements with loop-gap resonators
NASA Astrophysics Data System (ADS)
Subczynski, Witold K.; Felix, Christopher C.; Klug, Candice S.; Hyde, James S.
2005-10-01
Measurement of the bimolecular collision rate between a spin label and oxygen is conveniently carried out using a gas permeable plastic sample tube of small diameter that fits a loop-gap resonator. It is often desirable to concentrate the sample by centrifugation in order to improve the signal-to-noise ratio (SNR), but the deformable nature of small plastic sample tubes presents technical problems. Solutions to these problems are described. Two geometries were considered: (i) a methylpentene polymer, TPX, from Mitsui Chemicals, at X-band and (ii) Teflon tubing with 0.075 mm wall thickness at Q-band. Sample holders were fabricated from Delrin that fit the Eppendorf microcentrifuge tubes and support the sample capillaries. For TPX, pressure of the sealant at the end of the sample tube against the Delrin sample holder provided an adequate seal. For Teflon, the holder permitted introduction of water around the tube in order to equalize pressures across the sealant during centrifugation. Typically, the SNR was improved by a factor of five to eight. Oxygen accessibility applications in site-directed spin labeling studies are discussed.
Manufacture of thin-walled clad tubes by pressure welding of roll bonded sheets
NASA Astrophysics Data System (ADS)
Schmidt, Hans Christian; Grydin, Olexandr; Stolbchenko, Mykhailo; Homberg, Werner; Schaper, Mirko
2017-10-01
Clad tubes are commonly manufactured by fusion welding of roll bonded metal sheets or, mechanically, by hydroforming. In this work, a new approach towards the manufacture of thin-walled tubes with an outer diameter to wall thickness ratio of about 12 is investigated, involving the pressure welding of hot roll bonded aluminium-steel strips. By preparing non-welded edges during the roll bonding process, the strips can be zip-folded and (cold) pressure welded together. This process routine could be used to manufacture clad tubes in a continuous process. In order to investigate the process, sample tube sections with a wall thickness of 2.1 mm were manufactured by U-and O-bending from hot roll bonded aluminium-stainless steel strips. The forming and welding were carried out in a temperature range between RT and 400°C. It was found that, with the given geometry, a pressure weld is established at temperatures starting above 100°C. The tensile tests yield a maximum bond strength at 340°C. Micrograph images show a consistent weld of the aluminium layer over the whole tube section.
Strong focusing effect of 660 nm laser by microsized tapered glass tubes with different diameters
NASA Astrophysics Data System (ADS)
Lin, Chongnan; Luo, Xujia; Zhu, Xiaoyang; Zhu, Li; Wang, Hongcheng; Zhang, Ao; Xu, Runyu; Qu, Zheng; Chen, Ximeng; Zhang, Weiyi; Shao, Jianxiong
2017-09-01
A laser with a wavelength of 660 nm was focused by microsized tapered glass tubes with different diameters of the exit. By using the 3-μm optical fiber and micrometer displacement stages, we measured the light intensity distribution around the focal spot, the focal distance, and the transmission coefficient of the light transmitted through these tubes. The focusing effect for the glass tubes with smaller outlet diameters of the exit was found to be much stronger than those with larger diameters of the exit. Furthermore, the dependence of the size and distance and the maximum intensity of the focal spot on the tubes' diameter of exit are obtained.
Krishna, Senthil G; Hakim, Mumin; Sebastian, Roby; Dellinger, Heather L; Tumin, Dmitry; Tobias, Joseph D
2017-05-01
In children, the size of the cuffed endotracheal tube is based on various age-based formulas. However, such formulas may over or underestimate the size of the cuffed endotracheal tube. There are no data on the impact of different-sized cuffed endotracheal tubes (ETT) on the intracuff pressure in children. The current study measures intracuff pressure with different-sized cuffed ETT. The study was conducted in an in vitro and in vivo phase. For the in vitro phase, 10 cuffed ETT of size 4.0, 4.5, and 5 mm internal diameter (ID) each were randomly placed inside a 1.0 cm ID plastic tube (mimicking the trachea), which was in turn connected to a 1 l test lung. After inflation of the cuff using the air leak test at a continuous positive airway pressure of 20 cmH 2 O, the intracuff pressure was measured. The in vivo phase was conducted in 100 children (4-8 years) and were randomly divided into two groups to receive either a cuffed endotracheal tube based on the Khine formula (Group R) or a cuffed endotracheal tube that was a half-size (0.5 mm ID) smaller (Group S). Following the inflation of the cuff to seal the trachea, the intracuff pressure was measured. In the in vitro phase, the intracuff pressure was 45 ± 6, 23 ± 1, and 14 ± 6 cmH 2 O with size 4.0, 4.5, and 5 mm ID cuffed ETT, respectively (F-test P < 0.001 for difference among three groups). In the in vivo phase, the mean intracuff pressure in Group R was 25 ± 19 cmH 2 O vs 37 ± 35 cmH 2 O in Group S (95% CI of difference: 1, 23; P = 0.039). If the cuffed endotracheal tube is too small, the trachea can still be sealed by inflating the cuff with additional air. However, this transforms the cuff from the intended high-volume, low-pressure cuff to an undesirable high-volume, high-pressure cuff. © 2017 John Wiley & Sons Ltd.
Measurements of system sharpness for two digital breast tomosynthesis systems
NASA Astrophysics Data System (ADS)
Marshall, N. W.; Bosmans, H.
2012-11-01
The aim of this work was to propose system sharpness parameters for digital breast tomosynthesis (DBT) systems that include the influence of focus size and focus motion for use in quality assurance protocols. X-ray focus size was measured using a multiple pinhole test object, while detector presampling modulation transfer function (MTF) was measured from projection images of a 10 cm × 10 cm, 1 mm thick steel edge, for the Siemens Inspiration and Hologic Selenia Dimensions DBT systems. The height of the edge above the table was then varied from 1 to 78 mm. The MTF expected from theory for the projection images was calculated from the measured detector MTF, focus size MTF and focus motion MTF and was compared against measured curves. Two methods were used to measure the in-plane MTF in the DBT volume: a tungsten wire of diameter 25 µm and an Al edge 0.2 mm thick, both imaged with a 15 mm thick poly(methyl methacrylate) (PMMA) plate. The in-depth point spread function (PSF) was measured using an angled tungsten wire. The full 3D MTF was estimated with a 0.5 mm diameter aluminium bead held in a 45 mm thick PMMA phantom, with the bead 15 and 65 mm above the table. Inspiration DBT projection images are saved at native detector resolution (85 µm), while the Dimensions re-bins projections to 140 µm pixels (2 × 2 binning); both systems used 2 × 2 binning of projection data before reconstruction. The 50% point for the MTF (MTF0.50) measured in the DBT projection images for the tube-travel direction fell as a function of height above the table from 3.60 to 0.90 mm-1 for the Inspiration system and from 2.50 to 1.20 mm-1 for the Dimensions unit. The maximum deviation of measured MTF0.50 from the calculated value was 13%. MTF0.50 measured in-plane (tube-travel direction) fell as a function of height above the table from 1.66 to 0.97 mm-1 for the Inspiration system and from 2.21 to 1.31 mm-1 for the Dimensions system. The full-width half-maximum for the in-depth PSF was 3.0 and 5.9 mm for the Inspiration and Dimensions systems, respectively. There was no difference in the 3D MTF curves, sectioned in the tube-travel direction, for bead heights of 15 and 65 mm above the table. A 25 µm tungsten wire held within a 15 mm thick PMMA plate was found to be a suitable test object for measurement of in-plane MTF. Evaluation of MTF as a function of height above the table, both in the projection images and in the reconstructed planes, provides important information on the impact of focus size and focus motion on the DBT system's imaging performance.
Measurements of system sharpness for two digital breast tomosynthesis systems.
Marshall, N W; Bosmans, H
2012-11-21
The aim of this work was to propose system sharpness parameters for digital breast tomosynthesis (DBT) systems that include the influence of focus size and focus motion for use in quality assurance protocols. X-ray focus size was measured using a multiple pinhole test object, while detector presampling modulation transfer function (MTF) was measured from projection images of a 10 cm × 10 cm, 1 mm thick steel edge, for the Siemens Inspiration and Hologic Selenia Dimensions DBT systems. The height of the edge above the table was then varied from 1 to 78 mm. The MTF expected from theory for the projection images was calculated from the measured detector MTF, focus size MTF and focus motion MTF and was compared against measured curves. Two methods were used to measure the in-plane MTF in the DBT volume: a tungsten wire of diameter 25 µm and an Al edge 0.2 mm thick, both imaged with a 15 mm thick poly(methyl methacrylate) (PMMA) plate. The in-depth point spread function (PSF) was measured using an angled tungsten wire. The full 3D MTF was estimated with a 0.5 mm diameter aluminium bead held in a 45 mm thick PMMA phantom, with the bead 15 and 65 mm above the table. Inspiration DBT projection images are saved at native detector resolution (85 µm), while the Dimensions re-bins projections to 140 µm pixels (2 × 2 binning); both systems used 2 × 2 binning of projection data before reconstruction. The 50% point for the MTF (MTF(0.50)) measured in the DBT projection images for the tube-travel direction fell as a function of height above the table from 3.60 to 0.90 mm(-1) for the Inspiration system and from 2.50 to 1.20 mm(-1) for the Dimensions unit. The maximum deviation of measured MTF(0.50) from the calculated value was 13%. MTF(0.50) measured in-plane (tube-travel direction) fell as a function of height above the table from 1.66 to 0.97 mm(-1) for the Inspiration system and from 2.21 to 1.31 mm(-1) for the Dimensions system. The full-width half-maximum for the in-depth PSF was 3.0 and 5.9 mm for the Inspiration and Dimensions systems, respectively. There was no difference in the 3D MTF curves, sectioned in the tube-travel direction, for bead heights of 15 and 65 mm above the table. A 25 µm tungsten wire held within a 15 mm thick PMMA plate was found to be a suitable test object for measurement of in-plane MTF. Evaluation of MTF as a function of height above the table, both in the projection images and in the reconstructed planes, provides important information on the impact of focus size and focus motion on the DBT system's imaging performance.
Massive aspiration past the tracheal tube cuff caused by closed tracheal suction system.
Dave, Mital H; Frotzler, Angela; Madjdpour, Caveh; Koepfer, Nelly; Weiss, Markus
2011-01-01
Aspiration past the tracheal tube cuff has been recognized to be a risk factor for the development of ventilator-associated pneumonia (VAP). This study investigated the effect of closed tracheal suctioning on aspiration of fluid past the tracheal tube cuff in an in vitro benchtop model. High-volume low pressure tube cuffs of 7.5 mm internal diameter (ID) were placed in a 22 mm ID artificial trachea connected to a test lung. Positive pressure ventilation (PPV) with 15 cm H₂O peak inspiratory pressure and 5 cm H₂O positive end-expiratory pressure (PEEP) was used. A closed tracheal suction system (CTSS) catheter (size 14Fr) was attached to the tracheal tube and suction was performed for 5, 10, 15, or 20 seconds under 200 or 300 cm H₂O suction pressures. Amount of fluid (mL) aspirated along the tube cuff and the airway pressure changes were recorded for each suction procedure. Fluid aspiration during different suction conditions was compared using Kruskal-Wallis and Mann-Whitney test (Bonferroni correction [α = .01]). During 10, 15, and 20 seconds suction, airway pressure consistently dropped down to -8 to -13 cm H₂O (P < .001) from the preset level. Fluid aspiration was never observed under PPV + PEEP but occurred always during suctioning. Aspiration along the tube cuff was higher with -300 cm H₂O than with -200 cm H₂O suction pressure (P < .001) and was much more during 15 and 20 seconds suction time as compared to 5 seconds (P < .001). Massive aspiration of fluid occurs along the tracheal tube cuff during suction with the closed tracheal suction system. © SAGE Publications 2011.
Shrinking plastic tubing and nonstandard diameters
NASA Technical Reports Server (NTRS)
Ruiz, W. V.; Thatcher, C. S.
1980-01-01
Process allows larger-than-normal postshrink diameters without splitting. Tetrafluoroethylene tubing on mandrel is supported within hot steel pipe by several small diameter coil sections. Rising temperature of mandrel is measured via thermocouple so assembly can be removed without overshrinking (and splitting) of tubing.
Adeyekun, Ademola A; Orji, Michael O
2015-01-01
Fetal biometry by ultrasound provides reliable and important information about fetal growth and wellbeing. Evaluation of the fetal posterior fossa is useful in the assessment of neural tube-defects. Studies on normal ultrasound fetal cerebellar appearance and diameter across gestational age (GA) are scanty in the Nigerian medical literature. This study was carried out to study normal fetal cerebellar appearance and diameter at various GAs among healthy pregnant Nigerian Africans. This was a prospective study of 450 healthy singleton pregnant women between 13 and 42 weeks gestation. A curvilinear probe with a 3.5 MHz transducer of a SonoAce X6 (Medison Inc., Korea 2010) scanner was used to assess fetal transcerebellar diameter (TCD) and appearance. GA was also determined using fetal biometric parameters such as the biparietal diameter, femur length, and abdominal circumference. Fetal cerebellar appearance was correlated against GA. The cerebellar appearance was graded into: Grade I: 164 fetuses (36.4%), Grade II; 102 fetuses (22.7%) and Grade III: 184 fetuses (40.9%). Mean GA and TCD was 21 weeks and 21.2 mm for Grade I; 28 weeks and 32.6 mm for Grade II; and 35 weeks and 47.1 mm for Grade III. There was significance difference among the cerebellar grades at the GA groups and transverse cerebellar diameter (P < 0.000). There is a gradual and steady change in ultrasonographic appearance of the fetal cerebellar and diameter appearance with advancing gestation. The changes ranged from anechoic, "pair of eye glass" appearance at second trimester to relatively echogenic, "dumb-bell" appearance at early third trimester, and solid, "fan-shape" in late third trimester.
Nelson, Eliza L; Boeving, Emily R
2015-12-01
Decades of research on the hand use patterns of nonhuman primates can be aptly summarized by the following phrase: measurement matters. There is a general consensus that simple reaching is a poor indicator of handedness in most species, while tasks that constrain how the hands are used elicit individual, and in some cases, population-level biases. The TUBE task has become a popular measure of handedness, although there is variability in its administration across studies. The goal of this study was to investigate whether TUBE performance is affected by tube diameter, with the hypothesis that decreasing tube diameter would increase task complexity, and therefore the expression of handedness. We predicted that hand preference strength, but not direction, would be affected by tube diameter. We administered the TUBE task using a 1.3 cm tube to Colombian spider monkeys, and compared their performance to a previous study using a larger 2.5 cm diameter tube. Hand preference strength increased significantly on the smaller diameter tube. Hand preference direction was not affected. Notably, spider monkeys performed the TUBE task using a single digit, despite the longstanding view that this species has poor dexterity. We encourage investigators who use the TUBE task to carefully consider the diameter of the tube used in testing, and to report digit use consistently across studies. In addition, we recommend that researchers who cannot use the TUBE task try to incorporate the key features from this task into their own species appropriate measures: bimanual coordination and precise digit use. © 2015 Wiley Periodicals, Inc.
Retrovirus Studies in Nonhuman Primates at Four Regional Primate Research Centers.
1990-09-30
inoculation of the vaginal mucosa with SIV-infected splenocytes. The Heterosexual Transmission of AIDS: A Simian Model. The overall objective of this...rhesus macaques. We have previously reported that SIV can be transmitted across the vaginal mucosa of female rhesus macaques (Miller, et. al., 1990). To...infused through a 2.5mm outer diameter (8 French) soft, plastic, pediatric nasogastric feeding tube (American Pharmaseal, Valencia, Ca.) into the 3 vaginal
Feasibility of Rough Terrain Forklift Trucks with a Road Speed Capability of 45 mph.
1986-05-01
Specifications Design Features Metric Camshaft : 2 in. (51 mm) diameter camshaft controls all valve and injector movement. Induction hardened alloy...Power Rating (Formula) ... 240 bhp 179 kW steel with gear drive. Crowned roller camshaft followers Rated Speed 1800rpm 1800 rpm for long camshaft and...with integral governor. Camshaft actuated Topi :,.Stop injectors. Lubricating Oil Cooler: Tube and fin type, two pass water cooled with spin-on full
Permeation fill-tube design for inertial confinement fusion target capsules
Rice, B. S.; Ulreich, J.; Fella, C.; ...
2017-03-22
A unique approach for permeation filling of nonpermeable inertial confinement fusion target capsules with deuterium–tritium (DT) is presented. This process uses a permeable capsule coupled into the final target capsule with a 0.03-mm-diameter fill tube. Leak free permeation filling of glow-discharge polymerization (GDP) targets using this method have been successfully demonstrated, as well as ice layering of the target, yielding an inner ice surface roughness of 1-more » $$\\unicode[STIX]{x03BC}$$m rms (root mean square). Finally, the measured DT ice-thickness profile for this experiment was used to validate a thermal model’s prediction of the same thickness profile.« less
Evaluation of a new laser-resistant fabric and copper foil-wrapped endotracheal tube.
Sosis, M B; Braverman, B; Caldarelli, D D
1996-07-01
The risk of an endotracheal tube's combustion during laser airway surgery necessitates the use of special anesthetic techniques and equipment to prevent this complication. This study was designed to evaluate the Laser-Trach(TM), a new laser-resistant rubber endotracheal tube for use during laser airway surgery. The Laser-Trach endotracheal tubes that were evaluated were size 6.0 mm internal diameter (ID) red rubber endotracheal tubes which had been commercially wrapped by Kendall-Sheridan (Mansfield, Mass.) with copper foil tape and overwrapped with fabric. The fabric layer was saturated with water prior to our tests, as recommended by the manufacturer. The Laser-Trach endotracheal tubes were compared with plain (bare) size 6.0 mm ID Rusch red rubber endotracheal tubes. The tubes under study were positioned horizontally on wet towels in air and had 5 L x min(-1) of oxygen flowing through them. They were subjected to continuous laser radiation at 40 W from either a CO2 or an Nd-YAG laser. The Nd-YAG laser was propagated via a 600-micron fiber bundle. Each laser was directed perpendicularly at the shaft of the endotracheal tube being studied, and its output was continued until a blowtorch fire occurred or 60 seconds had elapsed. Sixty seconds of CO2 laser fire did not ignite any of the eight Laser-Trach endotracheal tubes tested. However, blowtorch ignition of all eight bare rubber tubes tested occurred after 0.87 +/- 0.21 (mean +/- SD) seconds of CO2 laser fire. Nd-YAG laser contact with the Laser-Trach endotracheal tubes caused the perforation and blowtorch ignition of all eight tubes tested after 18.79 +/- 7.83 seconds. This was a significantly (P<.05) longer time than the 5.45 +/- 4.75 seconds required for the blowtorch ignition of all eight plain rubber endotracheal tubes tested with the Nd-YAG laser. Our results show that under the conditions of this study, the shafts of the Kendall-Sheridan Laser-Trach endotracheal tubes were resistant to the C02 laser. However, this endotracheal tube is not recommended for use with the Nd-YAG laser.
M3FT-16OR0203052-Test Design for FeCrAl Alloy Tube Irradiation in HFIR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Terrani, Kurt A.; Petrie, Christian M.
2016-05-01
This calculation summarizes thermal analyses of a flexible rabbit design for irradiating a variety of pressurized water reactor (PWR) cladding materials (stainless steel, iron-chromium aluminum [FeCrAl], Zircaloy, and Inconel) with variable dimensions at a temperature of 350 °C in the flux trap of the High Flux Isotope Reactor (HFIR). The design can accommodate standard cladding for outer diameters (ODs) of approximately 9.50 mm with thickness ranging from 0.30 mm to 0.70 mm. The length is generally between 10 and 50 mm. The specimens contain moly inserts with a variable OD that provides the heat flux necessary to achieve the designmore » temperature with such a small fixed gas gap. The primary outer containment is an Al-6061 housing with a slightly enlarged inner diameter (ID) of 9.60 mm. The specimen temperature is controlled by determining a helium/argon gas mixture specific to the as-built specimen and housing. Variables that affect the required gas mixture are the cladding material (thermal expansion, density, heat generation rate), cladding OD, housing ID, and cladding ID. This calculation documents the analyses performed to determine required gas mixtures for a variety of scenarios.« less
Spectral optimization for micro-CT.
Hupfer, Martin; Nowak, Tristan; Brauweiler, Robert; Eisa, Fabian; Kalender, Willi A
2012-06-01
To optimize micro-CT protocols with respect to x-ray spectra and thereby reduce radiation dose at unimpaired image quality. Simulations were performed to assess image contrast, noise, and radiation dose for different imaging tasks. The figure of merit used to determine the optimal spectrum was the dose-weighted contrast-to-noise ratio (CNRD). Both optimal photon energy and tube voltage were considered. Three different types of filtration were investigated for polychromatic x-ray spectra: 0.5 mm Al, 3.0 mm Al, and 0.2 mm Cu. Phantoms consisted of water cylinders of 20, 32, and 50 mm in diameter with a central insert of 9 mm which was filled with different contrast materials: an iodine-based contrast medium (CM) to mimic contrast-enhanced (CE) imaging, hydroxyapatite to mimic bone structures, and water with reduced density to mimic soft tissue contrast. Validation measurements were conducted on a commercially available micro-CT scanner using phantoms consisting of water-equivalent plastics. Measurements on a mouse cadaver were performed to assess potential artifacts like beam hardening and to further validate simulation results. The optimal photon energy for CE imaging was found at 34 keV. For bone imaging, optimal energies were 17, 20, and 23 keV for the 20, 32, and 50 mm phantom, respectively. For density differences, optimal energies varied between 18 and 50 keV for the 20 and 50 mm phantom, respectively. For the 32 mm phantom and density differences, CNRD was found to be constant within 2.5% for the energy range of 21-60 keV. For polychromatic spectra and CMs, optimal settings were 50 kV with 0.2 mm Cu filtration, allowing for a dose reduction of 58% compared to the optimal setting for 0.5 mm Al filtration. For bone imaging, optimal tube voltages were below 35 kV. For soft tissue imaging, optimal tube settings strongly depended on phantom size. For 20 mm, low voltages were preferred. For 32 mm, CNRD was found to be almost independent of tube voltage. For 50 mm, voltages larger than 50 kV were preferred. For all three phantom sizes stronger filtration led to notable dose reduction for soft tissue imaging. Validation measurements were found to match simulations well, with deviations being less than 10%. Mouse measurements confirmed simulation results. Optimal photon energies and tube settings strongly depend on both phantom size and imaging task at hand. For in vivo CE imaging and density differences, strong filtration and voltages of 50-65 kV showed good overall results. For soft tissue imaging of animals the size of a rat or larger, voltages higher than 65 kV allow to greatly reduce scan times while maintaining dose efficiency. For imaging of bone structures, usage of only minimum filtration and low tube voltages of 40 kV and below allow exploiting the high contrast of bone at very low energies. Therefore, a combination of two filtrations could prove beneficial for micro-CT: a soft filtration allowing for bone imaging at low voltages, and a variable stronger filtration (e.g., 0.2 mm Cu) for soft tissue and contrast-enhanced imaging. © 2012 American Association of Physicists in Medicine.
Curve micromachining on the edges of nitinol biliary stent by ultrashort pulses laser
NASA Astrophysics Data System (ADS)
Hung, Chia-Hung; Chang, Fuh-Yu
2017-05-01
In this study, a curve micromaching process on the edges of nitinol biliary stent was proposed by a femtosecond laser system with a galvano-mirror scanner. Furthermore, the outer diameter of nitinol tube was 5.116 mm, its inner diameter was 4.648 mm, and its length was 100 mm. The initial fabricated results of nitinol biliary stent represented that the edges of nitinol biliary stent were steep and squared by femtosecond laser. However, the results also indicated that if the laser movement path was precisely programmed by utilizing the unique characteristic of Gaussian beam of femtosecond laser with aligning the edges of stent, the radius of edges enhanced significantly from 9 μm to 42.5 μm. As a result, the edges of nitinol biliary stent can be successfully fabricated from squared edges to rounded-shaped edges with precise dimension, clean surface morphology, and minimal heat-affected zone remained. Hence, the nitinol biliary stent, after femtosecond laser micromachining, would not need any further post-process to remove heat-affected zone and the squared edges.
Experimental study on flame pattern formation and combustion completeness in a radial microchannel
NASA Astrophysics Data System (ADS)
Fan, Aiwu; Minaev, Sergey; Kumar, Sudarshan; Liu, Wei; Maruta, Kaoru
2007-12-01
Combustion behavior in a radial microchannel with a gap of 2.0 mm and a diameter of 50 mm was experimentally investigated. In order to simulate the heat recirculation, which is an essential strategy in microscale combustion devices, positive temperature gradients along the radial flow direction were given to the microchannel by an external heat source. A methane-air mixture was supplied from the center of the top plate through a 4.0 mm diameter delivery tube. A variety of flame patterns, including a stable circular flame and several unstable flame patterns termed unstable circular flame, single and double pelton-like flames, traveling flame and triple flame, were observed in the experiments. The regime diagram of all these flame patterns is presented in this paper. Some characteristics of the various flame patterns, such as the radii of stable and unstable circular flames, major combustion products and combustion efficiencies of all these flame patterns, were also investigated. Furthermore, the effect of the heat recirculation on combustion stability was studied by changing the wall temperature levels.
Testing limits to airflow perturbation device (APD) measurements.
Lopresti, Erika R; Johnson, Arthur T; Koh, Frank C; Scott, William H; Jamshidi, Shaya; Silverman, Nischom K
2008-10-31
The Airflow Perturbation Device (APD) is a lightweight, portable device that can be used to measure total respiratory resistance as well as inhalation and exhalation resistances. There is a need to determine limits to the accuracy of APD measurements for different conditions likely to occur: leaks around the mouthpiece, use of an oronasal mask, and the addition of resistance in the respiratory system. Also, there is a need for resistance measurements in patients who are ventilated. Ten subjects between the ages of 18 and 35 were tested for each station in the experiment. The first station involved testing the effects of leaks of known sizes on APD measurements. The second station tested the use of an oronasal mask used in conjunction with the APD during nose and mouth breathing. The third station tested the effects of two different resistances added in series with the APD mouthpiece. The fourth station tested the usage of a flexible ventilator tube in conjunction with the APD. All leaks reduced APD resistance measurement values. Leaks represented by two 3.2 mm diameter tubes reduced measured resistance by about 10% (4.2 cmH2O.sec/L for control and 3.9 cm H2O.sec/L for the leak). This was not statistically significant. Larger leaks given by 4.8 and 6.4 mm tubes reduced measurements significantly (3.4 and 3.0 cm cmH2O.sec/L, respectively). Mouth resistance measured with a cardboard mouthpiece gave an APD measurement of 4.2 cm H2O.sec/L and mouth resistance measured with an oronasal mask was 4.5 cm H2O.sec/L; the two were not significantly different. Nose resistance measured with the oronasal mask was 7.6 cm H2O.sec/L. Adding airflow resistances of 1.12 and 2.10 cm H2O.sec/L to the breathing circuit between the mouth and APD yielded respiratory resistance values higher than the control by 0.7 and 2.0 cm H2O.sec/L. Although breathing through a 52 cm length of flexible ventilator tubing reduced the APD measurement from 4.0 cm H2O.sec/L for the control to 3.6 cm H2O.sec/L for the tube, the difference was not statistically significant. The APD can be adapted for use in ventilated, unconscious, and uncooperative patients with use of a ventilator tube and an oronasal mask without significantly affecting measurements. Adding a resistance in series with the APD mouthpiece has an additive effect on resistance measurements, and can be used for qualitative calibration. A leak size of at least the equivalent of two 3.2 mm diameter tubes can be tolerated without significantly affecting APD measurements.
Premixed direct injection nozzle for highly reactive fuels
Ziminsky, Willy Steve; Johnson, Thomas Edward; Lacy, Benjamin Paul; York, William David; Uhm, Jong Ho; Zuo, Baifang
2013-09-24
A fuel/air mixing tube for use in a fuel/air mixing tube bundle is provided. The fuel/air mixing tube includes an outer tube wall extending axially along a tube axis between an inlet end and an exit end, the outer tube wall having a thickness extending between an inner tube surface having a inner diameter and an outer tube surface having an outer tube diameter. The tube further includes at least one fuel injection hole having a fuel injection hole diameter extending through the outer tube wall, the fuel injection hole having an injection angle relative to the tube axis. The invention provides good fuel air mixing with low combustion generated NOx and low flow pressure loss translating to a high gas turbine efficiency, that is durable, and resistant to flame holding and flash back.
Outcomes of using a sutureless bovine pericardial patch graft for Ahmed glaucoma valve implantation.
Quaranta, Luciano; Riva, Ivano; Floriani, Irene C
2013-01-01
To evaluate the long-term outcomes of a surgical technique using a sutureless bovine pericardial patch graft for the implantation of an Ahmed glaucoma valve (AGV). This was a pilot study on patients with primary open-angle glaucoma refractory to repeated surgical filtering procedures. All patients underwent AGV implant technique using a sutureless bovine pericardial patch graft. The pericardial membrane was cut using an ordinary corneal trephine with a diameter of 9.0 or 10.0 mm. The anterior part of the tube was covered with the graft and kept in place with fibrin glue. Subsequently, the cap was stitched all around the tube and the dissected conjunctiva was laid over it. Intraocular pressure (IOP) and complications were evaluated 1 week and 1, 3, 6, 12, and 24 months after surgery. The procedure was used to treat 20 eyes of 20 consecutive patients (12 men and 8 women: mean age [SD] 64.8 [7.8] years). Mean IOP was 28.1 mm Hg (SD 4.9) at baseline and decreased to 14.9 mm Hg (SD 1.5) 24 months after surgery (p<0.001). The overall mean number of topical medications was 3.1 (SD 0.5) at baseline and decreased to 1.4 (SD 0.8) after 24 months (p<0.001). During follow-up, there was no conjunctival erosion, thinning of pericardial patch graft over the tube, or tube exposure; no signs of endophthalmitis were recorded. The results suggest that the sutureless technique using a bovine pericardial graft patch is a safe and rapid procedure for AGV implantation.
Fabrication of MgF2 and LiF windows for the Hubble Space Telescope Imaging Spectrograph
NASA Technical Reports Server (NTRS)
Gormley, Daphne; Bottema, Murk; Darnell, Barbara; Fowler, Walter; Medenica, Walter
1988-01-01
Two prototype test windows (MgF2 and LiF) to be used on the 75-mm UV MAMA detector tubes for the Hubble Space Telescope Imaging Spectrograph are described. The spatial and optical constraints of this instrument dictate that the thickness of the window materials be no greater than 2-3 mm to achieve a minimum 50-percent transmission at hydrogen Lyman alpha (121.6 nm), and that the window must be domed to minimize optical aberrations and provide structural strength. The detector window has an input diameter of about 100 mm with a radius-of-curvature of 70 mm. The manufacturing processes involved in the fabrication of these windows is discussed, as well as test programs (optical and structural) to be performed at Goddard Space Flight Center.
Korzekwa, David A.; Bingert, John F.; Peterson, Dean E.; Sheinberg, Haskell
1995-01-01
A superconductive article is made by inserting a rigid mandrel into an internal cavity of a first metallic tube, said tube having an interior surface and an exterior surface, said interior surface defining the interior cavity, forming a layer of a superconductive material or superconductive precursor upon the exterior surface of said first metallic tube, machining the layer of superconductive material or superconductive precursor to a predetermined diameter to form an intermediate article configured for insertion into a second metallic tube having an interior diameter corresponding to the predetermined diameter, inserting the machined intermediate article into a second metallic tube having an internal diameter corresponding to the predetermined diameter of the intermediate article to form a composite intermediate article, reducing or ironing the composite intermediate article to a predetermined cross-sectional diameter, and sintering the reduced or ironed composite intermediate article at temperatures and for time sufficient for the superconductive material or superconductive precursor to exhibit superconductivity.
Korzekwa, D.A.; Bingert, J.F.; Peterson, D.E.; Sheinberg, H.
1995-07-18
A superconductive article is made by inserting a rigid mandrel into an internal cavity of a first metallic tube, said tube having an interior surface and an exterior surface, said interior surface defining the interior cavity, forming a layer of a superconductive material or superconductive precursor upon the exterior surface of said first metallic tube, machining the layer of superconductive material or superconductive precursor to a predetermined diameter to form an intermediate article configured for insertion into a second metallic tube having an interior diameter corresponding to the predetermined diameter, inserting the machined intermediate article into a second metallic tube having an internal diameter corresponding to the predetermined diameter of the intermediate article to form a composite intermediate article, reducing or ironing the composite intermediate article to a predetermined cross-sectional diameter, and sintering the reduced or ironed composite intermediate article at temperatures and for time sufficient for the superconductive material or superconductive precursor to exhibit superconductivity. 2 figs.
A position- and time-sensitive photon-counting detector with delay- line read-out
NASA Astrophysics Data System (ADS)
Jagutzki, Ottmar; Dangendorf, Volker; Lauck, Ronald; Czasch, Achim; Milnes, James
2007-05-01
We have developed image intensifier tubes with delay-anode read-out for time- and position-sensitive photon counting. The timing precision is better than 1 ns with 1000x1000 pixels position resolution and up to one megacounts/s processing rate. Large format detectors of 40 and 75 mm active diameter with internal helical-wire delay-line anodes have been produced and specified. A different type of 40 and 25 mm tubes with semi-conducting screen for image charge read-out allow for an economic and robust tube design and for placing the read-out anodes outside the sealed housing. Two types of external delay-line anodes, i.e. pick-up electrodes for the image charge, have been tested. We present tests of the detector and anode performance. Due to the low background this technique is well suited for applications with very low light intensity and especially if a precise time tagging for each photon is required. As an example we present the application of scintillator read-out in time-of-flight (TOF) neutron radiography. Further applications so far are Fluorescence Life-time Microscopy (FLIM) and Astronomy.
Doss, F. W.; Kline, J. L.; Flippo, K. A.; ...
2015-04-17
An indirectly-driven shock tube experiment fielded on the National Ignition Facility (NIF) was used to create a high-energy-density hydrodynamics platform at unprecedented scale. Scaling up a shear-induced mixing experiment previously fielded at OMEGA, the NIF shear platform drives 130 μm/ns shocks into a CH foam-filled shock tube (~ 60 mg/cc) with interior dimensions of 1.5 mm diameter and 5 mm length. The pulse-shaping capabilities of the NIF are used to extend the drive for >10 ns, and the large interior tube volumes are used to isolate physics-altering edge effects from the region of interest. The scaling of the experiment tomore » the NIF allows for considerable improvement in maximum driving time of hydrodynamics, in fidelity of physics under examination, and in diagnostic clarity. Details of the experimental platform and post-shot simulations used in the analysis of the platform-qualifying data are presented. Hydrodynamic scaling is used to compare shear data from OMEGA with that from NIF, suggesting a possible change in the dimensionality of the instability at late times from one platform to the other.« less
Displacer Diameter Effect in Displacer Pulse Tube Refrigerator
NASA Astrophysics Data System (ADS)
Zhu, Shaowei
2017-12-01
Gas driving displacer pulse tube refrigerators are one of the work recovery type of pulse tube refrigerators whose theoretical efficiency is the same as Stirling refrigerators'. Its cooling power is from the displacement of the displacer. Displace diameter, rod diameter and pressure drop of the regenerator influence the displacement, which are investigated by numerical simulation. It is shown that the displacement ratio of the displacer over the piston is almost not affected by the displacer diameter at the same rod diameter ratio, or displacer with different diameters almost has the same performance.
Lu, Haiyang; Ni, Guoquan; Li, Ruxin; Xu, Zhizhan
2010-03-28
This work intends to get a better understanding of cluster formation in supersonic nozzles of different geometries. The throat diameters d are within 0.26 mm < or = d < or = 0.62 mm, the half-opening-angle alpha within 4.2 degrees < or = alpha < or = 11.3 degrees, and the length L of the conical section is 17.5 mm (eight nozzles) or 12 mm (two nozzles). Thus the so-called "equivalent sonic-nozzle diameter d(eq)" for these conical nozzle geometries, defined by d(eq)=0.74 d/tan alpha (for monatomic gases), is in the range of 1.59 mm < or = d(eq) < or = 5.21 mm. Source temperature for the clustering experiments was T(0)=298 K, and the backing pressure P(0) was between 0.5 and 30 bars. The (average) cluster sizes observed for these conical nozzles deviate from the predictions of the simple stream-tube-model. These deviations are accounted for by introducing the so-called "effective equivalent sonic-nozzle diameter d(eq)*," defined as the product of the equivalent sonic-nozzle diameter d(eq) and a new parameter delta, d(eq)*=deltad(eq). The parameter delta serves to modify the equivalent diameters d(eq) of the conical nozzles, which are applied in the idealized cases where the gas flows are suggested to be formed through free jet expansion. Then, delta represents the deviation of the performance in cluster formation of the practical conical nozzles from those predicted based on the idealized picture. The experimental results show that the values of delta can be described by an empirical formula, depending on the gas backing pressure P(0) and the parameter d(eq) of the conical nozzles. The degradation of the performance of the present conical nozzles was found with the increase in P(0) and the larger d(eq). It was revealed that delta is inversely proportional to a fractional power (approximately 0.5-0.6) of the molecular density n(mol) in the gas flows under the present experimental conditions. The boundary layers effects are considered to be mainly responsible for the restriction of the performance of the conical nozzles in cluster formation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Song, Junho; Hynynen, Kullervo; Medical Biophysics, University of Toronto, ON, M4N 3M5
2009-04-14
Noninvasive transcranial therapy using high intensity focused ultrasound transducers has attracted high interest as a promising new modality for the treatments of brain related diseases. We describe the development of a 1372 element large scale hemispherical ultrasound phased array transducer operating at a resonant frequency of 306 kHz. The hemispherical array has a diameter of 31 cm and a 15.5 cm radius of curvature. It is constructed with piezoelectric (PZT-4) tube elements of a 10 mm in diameter, 6 mm in length and 1.4 mm wall thickness. Each element is quasi-air backed by attaching a cork-rubber membrane on the backmore » of the element. The acoustic efficiency of the element is determined to be approximately 50%. The large number of the elements delivers high power ultrasound and offers better beam steering and focusing capability. Comparisons of sound pressure-squared field measurements with theoretical calculations in water show that the array provides good beam steering and tight focusing capability over an efficient volume of approximately 100x100x80 mm{sup 3} with nominal focal spot size of approximately 2.3 mm in diameter at -6 dB. We also present its beam steering and focusing capability through an ex vivo human skull by measuring pressure-squared amplitude after phase corrections. These measurements show the same efficient volume range and focal spot sizes at -6 dB as the ones in water without the skull present. These results indicate that the array is sufficient for use in noninvasive transcranial ultrasound therapy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rahman, Md. Lutfor; Nourin, Farah Nazifa, E-mail: farahnazifanourin@gmail.com; Salsabil, Zaimaa
Thermal control is an important topic for thermal management of small electrical and electronic devices. Closed loop pulsating heat pipe (CLPHP) arises as the best solution for thermal control. The aim of this experimental study is to search a CLPHP of better thermal performance for cooling different electrical and electronic devices. In this experiment, methanol is used as working fluid. The effect of using methanol as a working fluid is studied on thermal performance in different filling ratios and angles of inclination. A copper capillary tube is used where the inner diameter is 2 mm,outer diameter is 2.5 mm andmore » 250 mm long. The CLPHP has 8 loops where the evaporation section is 50 mm, adiabatic section is 120 mm and condensation section is 80 mm. The experiment is done using FR of 40%-70% with 10% of interval and angles of inclination 0° (vertical), 30°, 45°, 60° varying heat input. The results are compared on the basis of evaporator temperature, condenser temperature and their differences, thermal resistance, heat transfer co-efficient, power input and pulsating time. The results demonstrate the effect of methanol in different filling ratios and angles of inclination. M ethanol shows better performance at 30° inclination with 40% FR.« less
Explosion-Induced Implosions of Cylindrical Shell Structures
NASA Astrophysics Data System (ADS)
Ikeda, C. M.; Duncan, J. H.
2010-11-01
An experimental study of the explosion-induced implosion of cylindrical shell structures in a high-pressure water environment was performed. The shell structures are filled with air at atmospheric pressure and are placed in a large water-filled pressure vessel. The vessel is then pressurized to various levels P∞=αPc, where Pc is the natural implosion pressure of the model and α is a factor that ranges from 0.1 to 0.9. An explosive is then set off at various standoff distances, d, from the model center line, where d varies from R to 10R and R is the maximum radius of the explosion bubble. High-speed photography (27,000 fps) was used to observe the explosion and resulting shell structure implosion. High-frequency underwater blast sensors recorded dynamic pressure waves at 6 positions. The cylindrical models were made from aluminum (diameter D = 39.1 mm, wall thickness t = 0.89 mm, length L = 240 mm) and brass (D = 16.7 mm, t = 0.36 mm, L=152 mm) tubes. The pressure records are interpreted in light of the high-speed movies. It is found that the implosion is induced by two mechanisms: the shockwave generated by the explosion and the jet formed during the explosion-bubble collapse. Whether an implosion is caused by the shockwave or the jet depends on the maximum bubble diameter and the standoff distance.
NASA Astrophysics Data System (ADS)
Joghan, Hamed Dardaei; Staupendahl, Daniel; Hassan, Hamad ul; Henke, Andreas; Keesser, Thorsten; Legat, Francois; Tekkaya, A. Erman
2018-05-01
Tube hydroforming is one of the most important manufacturing processes for the production of exhaust systems. Tube hydroforming allows generating parts with highly complex geometries with the forming accuracies needed in the automotive sector. This is possible due to the form-closed nature of the production process. One of the main cost drivers is tool manufacturing, which is expensive and time consuming, especially when forming large parts. To cope with the design trend of individuality, which is gaining more and more importance and leads to a high number of product variants, a new flexible tool design was developed. The designed tool offers a high flexibility in manufacturing different shapes and geometries of tubes with just local alterations and relocation of tool segments. The tolerancing problems that segmented tools from the state of the art have are overcome by an innovative and flexible die holder design. The break-even point of this initially more expensive tool design is already overcome when forming more than 4 different tube shapes. Together with an additionally designed rotary hydraulic tube feeding system, a highly adaptable forming setup is generated. To investigate the performance of the developed tool setup, a study on geometrical and process parameters during forming of a spherical dome was done. Austenitic stainless steel (grade 1.4301) tube with a diameter of 40 mm and a thickness of 1.5 mm was used for the investigations. The experimental analyses were supported by finite element simulations and statistical analyses. The results show that the flexible tool setup can efficiently be used to analyze the interaction of the inner pressure, friction, and the location of the spherical dome and demonstrate the high influence of the feeding rate on the formed part.
Tsugawa, C; Nishijima, E; Muraji, T; Yoshimura, M; Tsubota, N; Asano, H
1997-01-01
The authors have designed a coil airway stent using a thermal shape-memory titanium-nickel alloy (SMA) to relieve airway collapse in children. A characteristic of alloy allowed the stent to be enclosed in the thin introducer tube and to position it bronchoscopically in the collapsed airway. When the stent is warmed to 37 to 40 degrees C, it expands to the memorized diameter and stents the airway. In eight rabbits, an experimental model of potentially fatal tracheomalacia was created by fracturing the tracheal cartilages. The stents of 6 mm in diameter and 15 mm in length were placed, and then the stents were recovered to their original shape within 1 minute. All rabbits except one showed no respiratory symptoms during the follow-up period. Results of bronchoscopy performed 6 and 10 months after implantation showed satisfactory patency of the trachea. The rabbits were killed for histological evaluation 6 to 28 months after implantation. The specimens showed little proliferation of granulation and no dislodgement of the stents. This procedure was attempted in two children who had severe bronchomalacia. One 5-year-old patient underwent implantation with a stent of 5 mm in diameter and 25 mm in length into the left main bronchus. The patient was relieved from apneic attacks. The stent was removed 2 years after implantation after a remarkable improvement of ventilation. The other patient with left bronchomalacia, age 1 year 2 months, underwent implantation with a 5-mm x 20-mm stent. The animal experiment and clinical experience indicated that (1) this stent can be easily inserted and removed bronchoscopically, (2) the stent has good tissue compatibility and little interference of mucociliary function, and (3) the SMA stent is a promising therapeutic adjunct in the management of children with severe tracheobronchomalacia.
Optical instrument for measurement of vaginal coating thickness by drug delivery formulations
NASA Astrophysics Data System (ADS)
Henderson, Marcus H.; Peters, Jennifer J.; Walmer, David K.; Couchman, Grace M.; Katz, David F.
2005-03-01
An optical device has been developed for imaging the human vaginal epithelial surfaces, and quantitatively measuring distributions of coating thickness of drug delivery formulations—such as gels—applied for prophylaxis, contraception or therapy. The device consists of a rigid endoscope contained within a 27-mm-diam hollow, polished-transparent polycarbonate tube (150mm long) with a hemispherical cap. Illumination is from a xenon arc. The device is inserted into, and remains stationary within the vagina. A custom gearing mechanism moves the endoscope relative to the tube, so that it views epithelial surfaces immediately apposing its outer surface (i.e., 150mm long by 360° azimuthal angle). Thus, with the tube fixed relative to the vagina, the endoscope sites local regions at distinct and measurable locations that span the vaginal epithelium. The returning light path is split between a video camera and photomultiplier. Excitation and emission filters in the light path enable measurement of fluorescence of the sited region. Thus, the instrument captures video images simultaneously with photometric measurement of fluorescence of each video field [˜10mm diameter; formulations are labeled with 0.1%w/w United States Pharmacoepia (USP) injectable sodium fluorescein]. Position, time and fluorescence measurements are continuously displayed (on video) and recorded (to a computer database). The photomultiplier output is digitized to quantify fluorescence of the endoscope field of view. Quantification of the thickness of formulation coating of a surface sited by the device is achieved due to the linear relationship between thickness and fluorescence intensity for biologically relevant thin layers (of the order of 0.5mm). Summary measures of coating have been developed, focusing upon extent, location and uniformity. The device has begun to be applied in human studies of model formulations for prophylaxis against infection with HIV and other sexually transmitted pathogens.
[Progress in research on reconstruction of fallopian tube after ligation].
Cheng, Q P
1984-05-01
An informative summary of foreign developments in microsurgical techniques used in post ligation fallopian tube reconstruction is discussed. In China, reconstructive surgery is limited to the traditional method of placing frames in the fallopian tube in order to prevent occlusion and/or anastomotic stenosis. The author maintains that this widely used technique is problematic due to frequent complications from injuries to the endosalpinx during implantation; moreover, frequent slippage of the commonly used polyvinyl frames also poses a number of problems. Since 1974, the authors have used type II catgut in suturing tissue following tubal-ampula anastomosis and fimbrial fistulation surgery. Polyvinyl tubing (inner diameter .5 mm) has also been used successfully in stenotic-stenotic and stenotic-interstial anastomotic surgery at Zhejiang Medical University (specific techniques and results are not disclosed). The author maintains that the wide discrepancy in the number of post surgery extrauterine pregnancies (0%-27% of cases) may be due to factors such as the severity and and extent of injuries to the fallopian tube during surgery, postoperative infections, and mucosal occlusion.
New drainage tunnel of the tunnel Višňové - design and excavation
NASA Astrophysics Data System (ADS)
Jurík, Igor; Grega, Ladislav; Valko, Jozef; Janega, Peter
2017-09-01
The actual pilot tunnel dated to the period of geological and hydrogeological survey, is designed as a part of the tunnel Višňové, which is located at the section of the D1 motorway Lietavská Lúčka - Višňové - Dubná Skala in Slovakia. Drainage tunnel will be used for the drainage of the main tunnel tubes, where the maximum inflow from the eastern portal is greater than 250 l.s-1. Overlapping of the initial pilot tunnel with the profile of the southern tunnel tube led to the demolition of the portal sections of the pilot tunnel during the excavation of main tunnel tubes. These sections were replaced by new drainage tunnels, with the lengths of 288.0 meters from west portal and 538.0 meters from eastern portal, to ensure access from both portals. The new drainage tunnel is excavated under the level of the two main tunnel tubes. Drainage pipes with a diameter of 250 mm will be installed from cleaning niches in the main tunnel tubes to the new drainage tunnel.
Chen, Xin; Hu, Rui; Bai, Fan
2017-01-01
The influences of diameter and length of the Fe−N4-patched carbon nanotubes (Fe−N4/CNTs) on oxygen reduction reaction (ORR) activity were investigated by density functional theory method using the BLYP/DZP basis set. The results indicate that the stability of the Fe−N4 catalytic site in Fe−N4/CNTs will be enhanced with a larger tube diameter, but reduced with shorter tube length. A tube with too small a diameter makes a Fe−N4 site unstable in acid medium since Fe−N and C−N bonds must be significantly bent at smaller diameters due to hoop strain. The adsorption energy of the ORR intermediates, especially of the OH group, becomes weaker with the increase of the tube diameter. The OH adsorption energy of Fe−N4/CNT with the largest tube diameter is close to that on Pt(111) surface, indicating that its catalytic property is similar to Pt. Electronic structure analysis shows that the OH adsorption energy is mainly controlled by the energy levels of Fe 3d orbital. The calculation results uncover that Fe−N4/CNTs with larger tube diameters and shorter lengths will exhibit better ORR activity and stability. PMID:28772903
PVDF core-free actuator for Braille displays: design, fabrication process, and testing
NASA Astrophysics Data System (ADS)
Levard, Thomas; Diglio, Paul J.; Lu, Sheng-Guo; Gorny, Lee J.; Rahn, Christopher D.; Zhang, Q. M.
2011-04-01
Refreshable Braille displays require many, small diameter actuators to move the pins. The electrostrictive P(VDF-TrFECFE) terpolymer can provide the high strain and actuation force under modest electric fields that are required of this application. In this paper, we develop core-free tubular actuators and integrate them into a 3 × 2 Braille cell. The films are solution cast, stretched to 6 μm thick, electroded, laminated into a bilayer, rolled into a 2 mm diameter tube, bonded, and provided with top and bottom contacts. Experimental testing of 17 actuators demonstrates significant strains (up to 4%). A novel Braille cell is designed and fabricated using six of these actuators.
Building multidevice pipeline constructs of favorable metal coverage: a practical guide.
Shapiro, M; Raz, E; Becske, T; Nelson, P K
2014-08-01
The advent of low-porosity endoluminal devices, also known as flow diverters, exemplified by the Pipeline in the United States, produced the greatest paradigm shift in cerebral aneurysm treatment since the introduction of detachable coils. Despite robust evidence of efficacy and safety, key questions regarding the manner of their use remain unanswered. Recent studies demonstrated that the Pipeline device geometry can dramatically affect its metal coverage, emphasizing the negative effects of oversizing the device relative to its target vessels. This follow-up investigation focuses on the geometry and coverage of multidevice constructs. A number of Pipeline devices were deployed in tubes of known diameters and photographed, and the resultant coverage was determined by image segmentation. Multidevice segmentation images were created to study the effects of telescoped devices and provide an estimate of coverages resulting from device overlap. Double overlap yields a range of metal coverage, rather than a single value, determined by the diameters of both devices, the size of the recipient artery, and the degree to which strands of the overlapped devices are coregistered with each other. The potential variation in coverage is greatest during overlap of identical-diameter devices, for example, ranging from 24% to 41% for two 3.75-mm devices deployed in a 3.5-mm vessel. Overlapping devices of progressively different diameters produce correspondingly more uniform ranges of coverage, though reducing the maximum achievable value, for example, yielding a 33%-34% range for 3.75- and 4.75-mm devices deployed in the same 3.5-mm vessel. Rational strategies for building multidevice constructs can achieve favorable geometric outcomes. © 2014 by American Journal of Neuroradiology.
Anatomical and Radiological Aspects of the Supratrochlear Foramen in Brazilians
Gutfiten-Schlesinger, Gabriel; Leite, Túlio FO; Pires, Lucas AS; Silva, Julio G.
2016-01-01
Introduction The supratrochlear foramen is an anatomic variation of great clinical and anthropologic interest. Although many studies addressed this subject in different ethnic groups, there are no studies regarding Brazilians. Aim To verify the incidence and morphometric measures of the supratrochlear foramen in Brazilian humeri. Materials and Methods A total of 330 dry humeri were analysed and divided in three groups: bones presenting the supratrochlear foramen (Group 1), bones displaying a translucent foramen (Group 2) and humeri without the foramen (Group 3). The aperture was measured with a digital vernier caliper. Radiographic pictures with different incidences were taken. Results Our analysis showed that 22.5% of humeri belonged in Group 1, 41.2% in Group 2, and 36.3% in Group 3. The mean vertical diameter and the mean horizontal diameter of the supratrochlear foramen on the left side were 2.779±2.050 mm and 2.332±1.23 mm, respectively. The mean vertical diameter and the mean horizontal diameter of the foramen on the right side were 2.778±2.197 mm, and 2.365±1.396 mm, respectively. The student’s t-test showed that there was no significant difference regarding the size of the foramen between both sides. The best X-ray machine setup was 50 kilo voltage and 0.08 milliamperage per second, associated with a slight increase in the distance of the x-ray tube. Conclusion The aperture seems to be the key point during the pre-operative planning of intramedullary fixation, since it has direct relation to the size of the intramedullary canal, thus, being an entity of clinical, anatomical, anthropological, radiological, and surgical interest. PMID:27790415
Workshop II On Unsteady Separated Flow Proceedings
1988-07-28
was static stall angle of 12 ° . achieved by injecting diluted food coloring at the apex through a 1.5 mm diameter tube placed The response of the wing...differences with uniform step size in q, and trailing -. 75 three- pront differences with uniform step size in ,, ,,as used The nonlinearity of the...flow prop- "Kutta condition." erties for slender 3D wings are addressed. To begin the The present paper emphasizes recent progress in the de- study
Lin, Y; Ghijsen, M T; Gao, H; Liu, N; Nalcioglu, O; Gulsen, G
2014-01-01
Fluorescence tomography (FT) is a promising molecular imaging technique that can spatially resolve both fluorophore concentration and lifetime parameters. However, recovered fluorophore parameters highly depend on the size and depth of the object due to the ill-posedness of the FT inverse problem. Structural a priori information from another high spatial resolution imaging modality has been demonstrated to significantly improve FT reconstruction accuracy. In this study, we have constructed a combined magnetic resonance imaging (MRI) and FT system for small animal imaging. A photo-multiplier tube (PMT) is used as the detector to acquire frequency domain FT measurements. This is the first MR-compatible time-resolved FT system that can reconstruct both fluorescence concentration and lifetime maps simultaneously. The performance of the hybrid system is evaluated with phantom studies. Two different fluorophores, Indocyanine Green (ICG) and 3-3′ Diethylthiatricarbocyanine Iodide (DTTCI), which have similar excitation and emission spectra but different lifetimes, are utilized. The fluorescence concentration and lifetime maps are both reconstructed with and without the structural a priori information obtained from MRI for comparison. We show that the hybrid system can accurately recover both fluorescence intensity and lifetime within 10% error for two 4.2 mm-diameter cylindrical objects embedded in a 38 mm-diameter cylindrical phantom when MRI structural a priori information is utilized. PMID:21753235
Experimental validation of L-shell x-ray fluorescence computed tomography imaging: phantom study
Bazalova-Carter, Magdalena; Ahmad, Moiz; Xing, Lei; Fahrig, Rebecca
2015-01-01
Abstract. Thanks to the current advances in nanoscience, molecular biochemistry, and x-ray detector technology, x-ray fluorescence computed tomography (XFCT) has been considered for molecular imaging of probes containing high atomic number elements, such as gold nanoparticles. The commonly used XFCT imaging performed with K-shell x rays appears to have insufficient imaging sensitivity to detect the low gold concentrations observed in small animal studies. Low energy fluorescence L-shell x rays have exhibited higher signal-to-background ratio and appeared as a promising XFCT mode with greatly enhanced sensitivity. The aim of this work was to experimentally demonstrate the feasibility of L-shell XFCT imaging and to assess its achievable sensitivity. We built an experimental L-shell XFCT imaging system consisting of a miniature x-ray tube and two spectrometers, a silicon drift detector (SDD), and a CdTe detector placed at ±120 deg with respect to the excitation beam. We imaged a 28-mm-diameter water phantom with 4-mm-diameter Eppendorf tubes containing gold solutions with concentrations of 0.06 to 0.1% Au. While all Au vials were detectable in the SDD L-shell XFCT image, none of the vials were visible in the CdTe L-shell XFCT image. The detectability limit of the presented L-shell XFCT SDD imaging setup was 0.007% Au, a concentration observed in small animal studies. PMID:26839910
Evaluation of Urban Air Quality By Passive Sampling Technique
NASA Astrophysics Data System (ADS)
Nunes, T. V.; Miranda, A. I.; Duarte, S.; Lima, M. J.
Aveiro is a flat small city in the centre of Portugal, close to the Atlantic coast. In the last two decades an intensive development of demographic, traffic and industry growth in the region was observed which was reflected on the air quality degrada- tion. In order to evaluate the urban air quality in Aveiro, a field-monitoring network by passive sampling with high space resolution was implemented. Twenty-four field places were distributed in a area of 3x3 Km2 and ozone and NO2 concentrations were measured. The site distribution density was higher in the centre, 250x250 m2 than in periphery where a 500x500 m2 grid was used. The selection of field places took into consideration the choice criteria recommendation by United Kingdom environmental authorities, and three tubes and a blank tube for each pollutant were used at each site. The sampling system was mounted at 3m from the ground usually profiting the street lampposts. Concerning NO2 acrylic tubes were used with 85 mm of length and an in- ternal diameter of 12mm, where in one of the extremities three steel grids impregnated with a solution of TEA were placed and fixed with a polyethylene end cup (Heal et al., 1999); PFA Teflon tube with 53 mm of length and 9 mm of internal diameter and three impregnated glass filters impregnated with DPE solution fixed by a teflon end cup was used for ozone sampling (Monn and Hargartner, 1990). The passive sampling method for ozone and nitrogen dioxide was compared with continuous measurements, but the amount of measurements wasnSt enough for an accurate calibration and validation of the method. Although this constraint the field observations (June to August 2001) for these two pollutants assign interesting information about the air quality in the urban area. A krigger method of interpolation (Surfer- Golden Software-2000) was applied to field data to obtain isolines distribution of NO2 and ozone concentration for the studied area. Even the used passive sampling method has many limitations it is possi- ble to say that the NO2 concentrations were strictly related with traffic intensity and in the centre 3 to 10 times higher values were observed than the incoming air to the city; on the contrary the ozone seems to be consumed where we observe the highest NO2 concentrations. Heal, M. R.; O'Donoghue, M. A. and Cape, J. N., Overestimation of Urban Nitrogen Dioxide by Passive Sampling Tubes: a comparative exposure and model study, Atmo- spheric Environment, Vol 33, pp 513-524, 1999 Monn, Ch., Hangartner, M., Passive Sampling for Ozone, J. of Air and Waste Management Association, Vol. 40, Nz 3, 1990
NASA Astrophysics Data System (ADS)
Chen, Han; Danielsson, Mats; Xu, Cheng
2016-06-01
We are developing a photon-counting spectral CT detector with a small pixel size of 0.4× 0.5 mm2, offering a potential advantage for better visualization of small structures in pediatric patients. The purpose of this study is to determine the patient size dependent scanning parameters (kVp and mAs) for pediatric CT in two imaging cases: adipose imaging and iodinated blood imaging. Cylindrical soft-tissue phantoms of diameters between 10-25 cm were used to mimic patients of different ages from 0 to 15 y. For adipose imaging, a 5 mm diameter adipose sphere was assumed as an imaging target, while in the case of iodinated imaging, an iodinated blood sphere of 1 mm in diameter was assumed. By applying the geometry of a commercial CT scanner (GE Lightspeed VCT), simulations were carried out to calculate the detectability index, {{d}\\prime 2} , with tube potentials varying from 40 to 140 kVp. The optimal kVp for each phantom in each imaging case was determined such that the dose-normalized detectability index, {{d}\\prime 2}/ dose, is maximized. With the assumption that the detectability index in pediatric imaging is required the same as in typical adult imaging, the value of mAs at optimal kVp for each phantom was selected to achieve a reference detectability index that was obtained by scanning an adult phantom (30 cm in diameter) in a typical adult CT procedure (120 kVp and 200 mAs) using a modeled energy-integrating system. For adipose imaging, the optimal kVps are 50, 60, 80, and 120 kVp, respectively, for phantoms of 10, 15, 20, and 25 cm in diameter. The corresponding mAs values required to achieve the reference detectability index are only 9%, 23%, 24%, and 54% of the mAs that is used for adult patients at 120 kVp, for 10, 15, 20, and 25 cm diameter phantoms, respectively. In the case of iodinated imaging, a tube potential of 60 kVp was found optimal for all phantoms investigated, and the mAs values required to achieve the reference detectability index are 2%, 9%, 37%, and 109% of the adult mAs. The results also indicate that with the use of respective optimal kVps, the photon-counting spectral system offers up to 30% higher {{d}\\prime 2}/ dose than the modeled energy-integrating system for adipose imaging, and 70% for iodinated imaging.
Spicher, G; Borchers, U
1985-06-01
Bioindicators serve to test the efficacy of disinfection and sterilization procedures. Such indicators mostly consist of a support (filter paper, as a rule) to which micro-organisms have been fixed by drying. The authors have used a thread as support and a special apparatus for semi-automatic preparation of the bioindicators. The components of the device are either commercially available or may be prepared from commercially available material without difficulty. The principle of the method is as follows: The thread serving as the support is drawn slowly, at constant speed, through the suspension of test organisms and dried in an air stream immediately afterwards. The apparatus consists of a cylindrical glass tube of a few centimeters in diameter, an electric motor slowly rotating the cylinder, a fan, a magnetic stirrer, and an ice-water bath. A small vial containing the germ suspension is immersed in the ice-water bath. The vial is sealed by a screw cap with two glass tubes of about 3 mm inner diameter passing through it. One of the glass tubes being bent in its upper part reaches far down into the vial to leave just enough play for free rotation of a magnetic stirring rod. This tube serves to introduce the thread into the germ suspension. The second straight tube does not reach as far down as the first one. Its lower opening should not be immersed in the germ suspension. This tube serves as a guide for the returning thread. Preparation begins by winding the thread to be soaked with the suspension around the cylinder.(ABSTRACT TRUNCATED AT 250 WORDS)
End Restraints for Impact-Energy-Absorbing Tube Specimens
NASA Technical Reports Server (NTRS)
Farley, G. L.; Modlin, J. T.
1985-01-01
Inexpensive device developed that eliminates tipping problem without affecting crushing process. Device consists of soft sponge-rubber insert approximately 0.5 inches (1.3 centimeters) thick, cut to same diameter as internal diameter of tube specimen. Metal washer, slightly smaller than internal diameter of tube, placed on top of rubber insert. Screw passed through washer and rubber insert and threaded into base of test machine. As screw tightened against washer, rubber insert compressed and expands radially. Radial expansion applies pressure against internal wall of tube specimen, which provides sufficient support to tube to prevent tipping.
Some heat transfer and hydrodynamic problems associated with superconducting cables (SPTL)
NASA Technical Reports Server (NTRS)
Hendricks, R. C.; Daney, D. E.; Yeroshenko, V. M.; Kuznetsov, Y. V.; Shevckenko, O. A.
1978-01-01
To study some effects of thermogravitation on (CIIK-SPTL) systems, a heated tube experiment was set up at Krzhizhanovsky Power Engineering Institute Moscow, U.S.S.R. Heat transfer data were taken with fluid helium flowing through a 2.85 m, 19 mm diameter uniformly heated horizontal tube. Temperatures were measured on the top and bottom of the tube at six axial locations with three other circumferential measurements made at (X/L) =57. Typical temperature profiles show significant variations both axially and circumferentially. The data are grouped using reduced Nusselt number (NuR) and the bulk expansion parameter for each axial location. The average data for 0.26 less than or equal to X/L less than or equal to 0.76 follow a power law relation with the average expansion parameter. System instabilities are noted and discussed. Future work including heat transfer in coaxial cylinders is discussed.
NASA Astrophysics Data System (ADS)
Hendrik; Sebleku, P.; Siswayanti, B.; Pramono, A. W.
2017-05-01
The manufacture of high critical temperature (Tc) Bi, Pb-Sr-Ca-Cu-O (HTS BPSCCO) superconductor wire fabricated by power-in-tube (PIT) is a multi-step process. The main difficulty is that the value of Tc superconductor wire determined by various factors for each step. The objective of this research is to investigate the effect of sintering parameters on the properties of final rolled material. The fabrication process of 1 m rolled-silver sheath monofilament superconductor BPSCCO wire using mechanical deformation process including rolling and drawing has been carried out. The pure silver powders were melted and formed into pure silver (Ag) tube. The tube was 10 mm in diameter with a sheath material: superconductor powders ratio of about 6 : 1. Starting powders, containing the nominal composition of Bi2-Sr2-Cam-1-Cum-Oy, were inserted into the pure silver tube and rolled until it reached a diameter of 4 mm. A typical area reduction ratio of about 5% per step has been proposed to prevent microcracking during the cold-drawing process. The process of rolling of the silver tube was subsequently repeated to obtain three samples and then followed by heat-treated at 820 °C, 840 °C, and 860 °C, respectively. The surface morphology was analyzed by using SEM; the crystal structure was studied by using X-RD, whereas the superconductivity was investigated by using temperature dependence resistivity measurement by using four-point probe technique. SEM images showed the porosity of the cross-sectional surface of the samples. The sample with low heating temperature showed porosity more than the one with high temperature. The value of critical temperature (Tc) of the sample with a dwelling time of heating of 8 hours is 70 K. At above 70 K, it shows the behavior of conductor properties. However, the porosity increased as the heating time increased up to 24 hours. The critical temperature was difficult to be identified due to its porosity. According to XRD results, the Bi-2212 phase is prominent in all samples.
NASA Technical Reports Server (NTRS)
Yep, Tze Wing
2001-01-01
Recent experiments have shown that low-density gas jets injected into a high-density gas undergo an instability mode leading to highly periodic oscillations in the flow field. The transition from laminar to turbulent flow in these jets is abrupt, without a gradual change in scales. Although this type of instability at high Richardson numbers has been attributed to buoyancy, direct physical evidence was not acquired through experiments. In this study, several experiments were conducted in Earth gravity and microgravity to acquire qualitative data on near field flow structure of helium jets injected into air. Microgravity conditions were simulated in the 2.2-second drop tower at NASA Glenn Research Center. The operating parameters of this study included the tube inside diameter, the jet Reynolds number, and the jet Richardson number. Tubes with inside diameters of 19.05 mm and 31.75 mm were used in the experiments conducted in the drop tower. The jet flow was analyzed using quantitative rainbow schlieren deflectometry, a non-intrusive line of sight measurement technique for the whole field. The flow structure was characterized by distributions of angular deflection and the resulting helium mole fraction obtained from color schlieren images taken at 60 Hz. Three sets of experimental data with respect to three schlieren fields of view were acquired for each tube. Results show that the jet in microgravity was up to 70 percent wider than that in Earth gravity. The global jet flow oscillations observed in Earth gravity were absent in microgravity, providing direct experimental evidence that the flow instability in the low-density jet was buoyancy-induced. This study provides quantitative details of temporal flow evolution as the experiments undergo change in gravity in the drop tower.
Diagnostics and Optimization of a Miniature High Frequency Pulse Tube Cryocooler
NASA Astrophysics Data System (ADS)
Garaway, I.; Veprik, A.; Radebaugh, R.
2010-04-01
A miniature, high energy density, pulse tube cryocooler with an inertance tube and reservoir has been developed, tested, diagnosed and optimized to provide appropriate cooling for size-limited cryogenic applications demanding fast cool down. This cryocooler, originally designed using REGEN 3.2 for 80 K, an operating frequency of 150 Hz and an average pressure of 5.0 MPa, has regenerator dimensions of 4.4 mm inside diameter and 27 mm length and is filled with ♯635 mesh stainless steel screen. Various design features, such as the use of compact heat exchangers and a miniature linear compressor, resulted in a remarkably compact pulse tube cryocooler. In this report, we present the preliminary test results and the subsequent diagnostic and optimization sequence performed to improve the overall design and operation of the complete cryocooler. These experimentally determined optimal parameters, though slightly different from those proposed in the initial numerical model, yielded 530 mW of gross cooling power at 120 K with an input electrical power of only 25 W. This study highlights the need to further establish our understanding of miniature, high frequency, regenerative cryocoolers, not only as a collection of independent subcomponents, but as one single working unit. It has also led to a list of additional improvements that may yet be made to even further improve the operating characteristics of such a complete miniature cryocooler.
Metal tube reducer is inexpensive and simple to operate
NASA Technical Reports Server (NTRS)
Mayfield, R. M.
1967-01-01
Low-cost metal tube reducer accepts tubing up to 1 inch outer diameter and can reduce this diameter to less than 1/2 inch with controlled wall thickness. This device can reduce all of the tube without waste. It produces extremely good surface finishes.
Leakproof Swaged Joints in Thin-Wall Tubing
NASA Technical Reports Server (NTRS)
Stuckenberg, F. H.; Crockett, L. K.; Snyder, W. E.
1986-01-01
Tubular inserts reinforce joints, reducing incidence of leaks. In new swaging technique, tubular inserts placed inside ends of both tubes to be joined. Made from thicker-wall tubing with outside diameter that matches inside diameter of thin tubing swaged, inserts support tube ends at joint. They ensure more uniform contact between swage fitting and tubing. New swaging technique developed for Al/Ti/V-alloy hydraulic supply lines.
Shapes and dynamics of miscible liquid/liquid interfaces in horizontal capillary tubes.
Stevar, M S P; Vorobev, A
2012-10-01
We report optical observations of the dissolution behaviour of glycerol/water, soybean oil/hexane, and isobutyric acid (IBA)/water binary mixtures within horizontal capillary tubes. Tubes with diameters as small as 0.2mm were initially filled with one component of the binary mixture (solute) and then immersed into a solvent-filled thermostatic bath. Both ends of the tubes were open, and no pressure difference was applied between the ends. In the case of glycerol/water and soybean oil/hexane mixtures, we managed to isolate the dissolution (the interfacial mass transfer) from the hydrodynamic motion. Two phase boundaries moving from the ends into the middle section of the tube with the speeds v∼D(1/3)t(-2/3)d(2) (D,t and d are the coefficient of diffusion, time and the diameter of the tube, respectively) were observed. The boundaries slowly smeared but their smearing occurred considerably slower than their motion. The motion of the phase boundaries cannot be explained by the dependency of the diffusion coefficient on concentration, and should be explained by the effect of barodiffusion. The shapes of the solute/solvent boundaries are defined by the balance between gravity and surface tension effects. The contact line moved together with the bulk interface: no visible solute remained on the walls after the interface passage. Changes in temperature and in the ratio between gravity and capillary forces altered the apparent contact angles. The IBA/water system had different behaviour. Below the critical (consolute) point, no dissolution was observed: IBA and water behaved like two immiscible liquids, with the IBA phase being displaced from the tube by capillary pressure (the spontaneous imbibition process). Above the critical point, two IBA/water interfaces could be identified, however the interfaces did not penetrate much into the tube. Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Ohuchi, Yoshito; Nakazono, Yoichi
2014-06-01
We have developed a water musical instrument that generates sound by the falling of water drops within resonance tubes. The instrument can give people who hear it the healing effect inherent in the sound of water. The sound produced by falling water drops arises from air- bubble vibrations. To investigate the impact of water depth on the air-bubble vibrations, we conducted experiments at varying values of water pressure and nozzle shape. We found that air-bubble vibration frequency does not change at a water depth of 50 mm or greater. Between 35 and 40 mm, however, the frequency decreases. At water depths of 30 mm or below, the air-bubble vibration frequency increases. In our tests, we varied the nozzle diameter from 2 to 4 mm. In addition, we discovered that the time taken for air-bubble vibration to start after the water drops start falling is constant at water depths of 40 mm or greater, but slower at depths below 40 mm.
Torsional Stability of Aluminum Alloy Seamless Tubing
NASA Technical Reports Server (NTRS)
Moore, R L; Paul, D A
1939-01-01
Torsion tests were made on 51ST aluminum-alloy seamless tubes having diameter-to-thickness ratios of from 77 to 139 and length-to-diameter ratios of from 1 to 60. The torsional strengths developed in the tubes which failed elastically (all tubes having lengths greater than 2 to 6 times the diameter) were in most cases within 10 percent of the value indicated by the theories of Donnel, Timoshenko, and Sturm, assuming a condition of simply supported ends.
NASA Astrophysics Data System (ADS)
Chauvin, A.; Jourdan, G.; Daniel, E.; Houas, L.; Tosello, R.
2011-11-01
We conducted a series of shock tube experiments to study the influence of a cloud of water droplets on the propagation of a planar shock wave. In a vertically oriented shock tube, the cloud of droplets was released downwards into the air at atmospheric pressure while the shock wave propagated upwards. Two shock wave Mach numbers, 1.3 and 1.5, and three different heights of clouds, 150 mm, 400 mm, and 700 mm, were tested with an air-water volume fraction and a droplet diameter fixed at 1.2% and 500 μm, respectively. From high-speed visualization and pressure measurements, we analyzed the effect of water clouds on the propagation of the shock wave. It was shown that the pressure histories recorded in the two-phase gas-liquid mixture are different from those previously obtained in the gas-solid case. This different behavior is attributed to the process of atomization of the droplets, which is absent in the gas-solid medium. Finally, it was observed that the shock wave attenuation was dependent on the exchange surface crossed by the shock combined with the breakup criterion.
Uterine and fetal dynamics during early pregnancy in mares.
Griffin, P G; Ginther, O J
1991-02-01
Fetal activity and mobility and changes in diameter of the allantoic fluid compartment in the uterine horns were studied in mares between days 69 and 81 of pregnancy by use of transrectal ultrasonography (n = 12) and transcervical videoendoscopy (n = 8). The insertion tube of the videoendoscope was positioned within the allantoic sac to permit viewing of the fetus and entrance to each uterine horn. Each uterine horn was divided ultrasonographically into 3 segments of equal length, and the horns were designated on the basis of side of umbilical attachment (cord vs noncord horns). The diameter of the allantoic fluid compartment in the cornual segments increased (P less than 0.05) over the cranial (18.6 +/- 1.9 mm), middle (35.6 +/- 2.9 mm), and caudal (51.7 +/- 4.4 mm) segments, but differences between cord and noncord horns were not evident. Dynamic changes in diameter of the allantoic fluid compartment in cornual segments (ultrasonography) and at the entrance to each uterine horn (videoendoscopy) were detected (no significant difference between methods). During continuous videoendoscopic viewing (17 to 60 min/mare), extreme changes in allantoic fluid compartment diameter (76 to 100% of maximum to 0 to 25% of maximum or vice-versa) occurred an equivalent of 2.6 times/h/horn entrance; changes had an average duration of 3.4 minutes. A change from 100% (maximal diameter) to 0% (no visible lumen) or vice-versa occurred an equivalent of 1.3 times/h/horn entrance. Sometimes the uterine wall was so closely constricted++ around the fetal-amniotic unit that no intervening allantoic fluid was ultrasonographically detectable whereas at other times the uterus in the same location was widely dilated.(ABSTRACT TRUNCATED AT 250 WORDS)
Rubartelli, Paolo; Terzi, Giacomo; Borgo, Lorenzo; Giachero, Corinna
2002-03-01
A patient with unstable angina was treated with elective Palmaz-Schatz stent implantation on a focal stenosis of the left circumflex artery. One year later, a large (13 mm in diameter) coronary artery aneurysm was diagnosed at angiography in the stented site. Intravascular ultrasound examination confirmed the presence of a true aneurysm located at the proximal end of the stent. The aneurysm was successfully treated with a Jostent Graft (Jomed Implantate) consisting of two slotted tube stainless steel stents supporting a polytetrafluoroethylene tube. The stent graft was implanted under intravascular ultrasound guidance. The 18-month angiographic follow-up showed good patency of the stent graft and complete exclusion of the aneurysm.
Uno, K; Jitsuno, T
2017-12-01
We developed a longitudinally excited N 2 laser with a simple driver circuit and a simple power supply. The N 2 laser consisted of a 20 cm-long glass tube with an inner diameter of 2.5 mm, a normal stable resonator formed by flat mirrors, a variable transformer, a neon sign transformer, a spark gap, and a 200 pF capacitance. The N 2 laser produced a laser pulse with an energy of 379 nJ and a pulse width of 7.5 ns at a repetition rate of 100 Hz. The laser beam was circular and had a Gaussian profile with a correlation factor of 0.992 93.
Characteristics of surface sterilization using electron cyclotron resonance plasma
NASA Astrophysics Data System (ADS)
Yonesu, Akira; Hara, Kazufumi; Nishikawa, Tatsuya; Hayashi, Nobuya
2016-07-01
The characteristics of surface sterilization using electron cyclotron resonance (ECR) plasma were investigated. High-energy electrons and oxygen radicals were observed in the ECR zone using electric probe and optical emission spectroscopic methods. A biological indicator (BI), Geobacillus stearothermophilus, containing 1 × 106 spores was sterilized in 120 s by exposure to oxygen discharges while maintaining a temperature of approximately 55 °C at the BI installation position. Oxygen radicals and high-energy electrons were found to be the sterilizing species in the ECR region. It was demonstrated that the ECR plasma could be produced in narrow tubes with an inner diameter of 5 mm. Moreover, sterilization tests confirmed that the spores present inside the narrow tube were successfully inactivated by ECR plasma irradiation.
Benett, William J.; Krulevitch, Peter A.
2001-01-01
A miniature connector for introducing microliter quantities of solutions into microfabricated fluidic devices, and which incorporates a molded ring or seal set into a ferrule cartridge, with or without a compression screw. The fluidic connector, for example, joins standard high pressure liquid chromatography (HPLC) tubing to 1 mm diameter holes in silicon or glass, enabling ml-sized volumes of sample solutions to be merged with .mu.l-sized devices. The connector has many features, including ease of connect and disconnect; a small footprint which enables numerous connectors to be located in a small area; low dead volume; helium leak-tight; and tubing does not twist during connection. Thus the connector enables easy and effective change of microfluidic devices and introduction of different solutions in the devices.
Extracorporeal tubing in the roller pump raceway: physical changes and particulate generation.
Spiwak, Allison J Bednarski; Horbal, Alexander; Leatherbury, Robert; Hansford, Derek J
2008-09-01
Plasticized polyvinyl chloride tubing is used as the blood conduit in the heart lung bypass circuit. The section in the roller pump undergoes rigorous compression. Fatigue leads to material changes in weight and length of the bulk material. Particles are released during normal pump operation. This study evaluates the time course of particle loss. Three segments of 1/2" ID tubing run in the raceway for 30-minute, 1-hour, or 2-hour. The fluid path of each segment includes an oxygenator; a castor oil blend was used for the prime. The 5 mL sample was acquired at 10 minute intervals. Raceway tubing segments were measured for a change in weight and length. The same procedure repeated with 1/4" ID and 3/8" ID tubing. All tubing increased at least 5 mm by the 2-hour trial. There were no remarkable changes in weight. Particles were measured for size and percent volume. Tubing with 1/2" ID performed most consistently for particle release during all trials. Particles were observed as small as 1 nm. Particles as large as 3 micron could be confirmed. For all tubing there was particle release by 30 minutes. Perfusionists must consider tubing inner diameter and wall thickness in choosing the pPVC for the raceway in order to minimize particulate emboli. This research suggests that 3/8" ID tubing produces spalls inconsistently compared to 2" ID tubing. Thinner wall thickness tubing also has the potential to limit spall formation.
Extracorporeal Tubing in the Roller Pump Raceway: Physical Changes and Particulate Generation
Bednarski Spiwak, Allison J.; Horbal, Alexander; Leatherbury, Robert; Hansford, Derek J.
2008-01-01
Abstract: Plasticized polyvinyl chloride tubing is used as the blood conduit in the heart lung bypass circuit. The section in the roller pump undergoes rigorous compression. Fatigue leads to material changes in weight and length of the bulk material. Particles are released during normal pump operation. This study evaluates the time course of particle loss. Three segments of ½″ ID tubing run in the raceway for 30-minute, 1-hour, or 2-hour. The fluid path of each segment includes an oxygenator; a castor oil blend was used for the prime. The 5 mL sample was acquired at 10 minute intervals. Raceway tubing segments were measured for a change in weight and length. The same procedure repeated with ¼″ ID and ⅜″ ID tubing. All tubing increased at least 5 mm by the 2-hour trial. There were no remarkable changes in weight. Particles were measured for size and percent volume. Tubing with ½″ ID performed most consistently for particle release during all trials. Particles were observed as small as 1 nm. Particles as large as 3 micron could be confirmed. For all tubing there was particle release by 30 minutes. Perfusionists must consider tubing inner diameter and wall thickness in choosing the pPVC for the raceway in order to minimize particulate emboli. This research suggests that ⅜″ ID tubing produces spalls inconsistently compared to ½″ ID tubing. Thinner wall thickness tubing also has the potential to limit spall formation. PMID:18853831
Spectral optimization for micro-CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hupfer, Martin; Nowak, Tristan; Brauweiler, Robert
2012-06-15
Purpose: To optimize micro-CT protocols with respect to x-ray spectra and thereby reduce radiation dose at unimpaired image quality. Methods: Simulations were performed to assess image contrast, noise, and radiation dose for different imaging tasks. The figure of merit used to determine the optimal spectrum was the dose-weighted contrast-to-noise ratio (CNRD). Both optimal photon energy and tube voltage were considered. Three different types of filtration were investigated for polychromatic x-ray spectra: 0.5 mm Al, 3.0 mm Al, and 0.2 mm Cu. Phantoms consisted of water cylinders of 20, 32, and 50 mm in diameter with a central insert of 9more » mm which was filled with different contrast materials: an iodine-based contrast medium (CM) to mimic contrast-enhanced (CE) imaging, hydroxyapatite to mimic bone structures, and water with reduced density to mimic soft tissue contrast. Validation measurements were conducted on a commercially available micro-CT scanner using phantoms consisting of water-equivalent plastics. Measurements on a mouse cadaver were performed to assess potential artifacts like beam hardening and to further validate simulation results. Results: The optimal photon energy for CE imaging was found at 34 keV. For bone imaging, optimal energies were 17, 20, and 23 keV for the 20, 32, and 50 mm phantom, respectively. For density differences, optimal energies varied between 18 and 50 keV for the 20 and 50 mm phantom, respectively. For the 32 mm phantom and density differences, CNRD was found to be constant within 2.5% for the energy range of 21-60 keV. For polychromatic spectra and CMs, optimal settings were 50 kV with 0.2 mm Cu filtration, allowing for a dose reduction of 58% compared to the optimal setting for 0.5 mm Al filtration. For bone imaging, optimal tube voltages were below 35 kV. For soft tissue imaging, optimal tube settings strongly depended on phantom size. For 20 mm, low voltages were preferred. For 32 mm, CNRD was found to be almost independent of tube voltage. For 50 mm, voltages larger than 50 kV were preferred. For all three phantom sizes stronger filtration led to notable dose reduction for soft tissue imaging. Validation measurements were found to match simulations well, with deviations being less than 10%. Mouse measurements confirmed simulation results. Conclusions: Optimal photon energies and tube settings strongly depend on both phantom size and imaging task at hand. For in vivo CE imaging and density differences, strong filtration and voltages of 50-65 kV showed good overall results. For soft tissue imaging of animals the size of a rat or larger, voltages higher than 65 kV allow to greatly reduce scan times while maintaining dose efficiency. For imaging of bone structures, usage of only minimum filtration and low tube voltages of 40 kV and below allow exploiting the high contrast of bone at very low energies. Therefore, a combination of two filtrations could prove beneficial for micro-CT: a soft filtration allowing for bone imaging at low voltages, and a variable stronger filtration (e.g., 0.2 mm Cu) for soft tissue and contrast-enhanced imaging.« less
NASA Astrophysics Data System (ADS)
Etminan, Amin; Harun, Zambri; Sharifian, Ahmad
2017-01-01
In this article distilled water and CuO particles with volume fraction of 1%, 2% and 4% are studied numerically. The steady state flow regime is considered laminar with Reynolds number of 100 and nanoparticles diameters (dp) are set in the range of 20 nm and 80 nm. The hydraulic diameter and the length of equilateral triangular channel are 8 mm and 1000 mm respectively. The problem is solved using finite volume method with constant heat flux for two sides and constant temperature for one side. Convective heat transfer coefficient, Nusselt number and convective heat transfer coefficient distribution on walls are investigated in details. The fluid flow is supposed to be one phase flow. It can be observed that nanofluid leads to a remarkable enhancement on heat transfer coefficient pressure loss through the channel. The computations reveal that the size of nanoparticles has no significant influence on heat transfer properties. Besides, the study shows a good agreement between current results and experimental data in the literatures.
Facilitated giga-seal formation with a just originated glass surface.
Böhle, T; Benndorf, K
1994-07-01
A simple technique of tip preparation in patch pipettes is described, which facilitates giga-seal formation. The pipettes were fabricated from thick-walled borosilicate glass tubing (external diameter 2.0 mm, internal diameter 0.5 mm) and the tips could be repeatedly broken in the bath. The pipette resistance correspondingly fell in steps of 3-20 M omega from about 80 M omega to about 2 M omega (double concentrated Tyrode). Scanning electron microscopy showed that the tip obtained after breaking was fairly plain. These broken tips were especially appropriate for patch-clamping. In cardiac myocytes in 11 out of 26 patches with Na+ channel activity, giga-seals developed spontaneously, i.e. without suction. In these patches the amplitude of the mean current with depolarizing pulses to -40 mV was significantly higher in comparison with patches formed under negative pressure. It is concluded that spontaneously sealed patches are most likely of planar configuration and the Na+ channel activity exceeds that in suction-induced patches.
Schroeder, Daniel C; Guschlbauer, Maria; Maul, Alexandra C; Cremer, Daniel A; Becker, Ingrid; de la Puente Bethencourt, David; Paal, Peter; Padosch, Stephan A; Wetsch, Wolfgang A; Annecke, Thorsten; Böttiger, Bernd W; Sterner-Kock, Anja; Herff, Holger
2017-01-01
Targeted temperature management (TTM) is widely used in critical care settings for conditions including hepatic encephalopathy, hypoxic ischemic encephalopathy, meningitis, myocardial infarction, paediatric cardiac arrest, spinal cord injury, traumatic brain injury, ischemic stroke and sepsis. Furthermore, TTM is a key treatment for patients after out-of-hospital cardiac-arrest (OHCA). However, the optimal cooling method, which is quick, safe and cost-effective still remains controversial. Since the oesophagus is adjacent to heart and aorta, fast heat-convection to the central blood-stream could be achieved with a minimally invasive oesophageal heat exchanger (OHE). To date, the optimal diameter of an OHE is still unknown. While larger diameters may cause thermal- or pressure-related tissue damage after long-term exposure to the oesophageal wall, smaller diameter (e.g., gastric tubes, up to 11mm) may not provide effective cooling rates. Thus, the objective of the study was to compare OHE-diameters of 11mm (OHE11) and 14.7mm (OHE14.7) and their effects on tissue and cooling capability. Pigs were randomized to OHE11 (N = 8) or OHE14.7 (N = 8). After cooling, pigs were maintained at 33°C for 1 hour. After 10h rewarming, oesophagi were analyzed by means of histopathology. The oesophagus of four animals from a separate study that underwent exactly the identical preparation and cooling protocol described above but received a maintenance period of 24h were used as histopathological controls. Mean cooling rates were 2.8±0.4°C°C/h (OHE11) and 3.0±0.3°C °C/h (OHE14.7; p = 0.20). Occasional mild acute inflammatory transepithelial infiltrates were found in the cranial segment of the oesophagus in all groups including controls. Deviations from target temperature were 0.1±0.4°C (OHE11) and 0±0.1°C (OHE14.7; p = 0.91). Rewarming rates were 0.19±0.07°C °C/h (OHE11) and 0.20±0.05°C °C/h (OHE14.7; p = 0.75). OHE with diameters of 11 mm and 14.7 mm achieve effective cooling rates for TTM and did not cause any relevant oesophageal tissue damage. Both OHE demonstrated acceptable deviations from target temperature and allowed for an intended rewarming rate (0.25°C/h).
Guschlbauer, Maria; Maul, Alexandra C.; Cremer, Daniel A.; Becker, Ingrid; de la Puente Bethencourt, David; Paal, Peter; Padosch, Stephan A.; Wetsch, Wolfgang A.; Annecke, Thorsten; Böttiger, Bernd W.; Sterner-Kock, Anja; Herff, Holger
2017-01-01
Background Targeted temperature management (TTM) is widely used in critical care settings for conditions including hepatic encephalopathy, hypoxic ischemic encephalopathy, meningitis, myocardial infarction, paediatric cardiac arrest, spinal cord injury, traumatic brain injury, ischemic stroke and sepsis. Furthermore, TTM is a key treatment for patients after out-of-hospital cardiac-arrest (OHCA). However, the optimal cooling method, which is quick, safe and cost-effective still remains controversial. Since the oesophagus is adjacent to heart and aorta, fast heat-convection to the central blood-stream could be achieved with a minimally invasive oesophageal heat exchanger (OHE). To date, the optimal diameter of an OHE is still unknown. While larger diameters may cause thermal- or pressure-related tissue damage after long-term exposure to the oesophageal wall, smaller diameter (e.g., gastric tubes, up to 11mm) may not provide effective cooling rates. Thus, the objective of the study was to compare OHE-diameters of 11mm (OHE11) and 14.7mm (OHE14.7) and their effects on tissue and cooling capability. Methods Pigs were randomized to OHE11 (N = 8) or OHE14.7 (N = 8). After cooling, pigs were maintained at 33°C for 1 hour. After 10h rewarming, oesophagi were analyzed by means of histopathology. The oesophagus of four animals from a separate study that underwent exactly the identical preparation and cooling protocol described above but received a maintenance period of 24h were used as histopathological controls. Results Mean cooling rates were 2.8±0.4°C°C/h (OHE11) and 3.0±0.3°C °C/h (OHE14.7; p = 0.20). Occasional mild acute inflammatory transepithelial infiltrates were found in the cranial segment of the oesophagus in all groups including controls. Deviations from target temperature were 0.1±0.4°C (OHE11) and 0±0.1°C (OHE14.7; p = 0.91). Rewarming rates were 0.19±0.07°C °C/h (OHE11) and 0.20±0.05°C °C/h (OHE14.7; p = 0.75). Conclusions OHE with diameters of 11 mm and 14.7 mm achieve effective cooling rates for TTM and did not cause any relevant oesophageal tissue damage. Both OHE demonstrated acceptable deviations from target temperature and allowed for an intended rewarming rate (0.25°C/h). PMID:28291783
2010-03-10
achieved by setting proper driver and driven pressures. A calibration of the tunnel was done for the decided freestream conditions with a pitot rake ...measurement. A rake of 12 pitot probes spanning the diameter of the nozzle (300 mm) was placed facing the freestream. The pitot pressures were... pitot rake and shock tube measurements, the freestream conditions for each of the observed rupture pressure are estimated. It was observed that of
Heat transfer direction dependence of heat transfer coefficients in annuli
NASA Astrophysics Data System (ADS)
Prinsloo, Francois P. A.; Dirker, Jaco; Meyer, Josua P.
2018-04-01
In this experimental study the heat transfer phenomena in concentric annuli in tube-in-tube heat exchangers at different annular Reynolds numbers, annular diameter ratios, and inlet fluid temperatures using water were considered. Turbulent flow with Reynolds numbers ranging from 15,000 to 45,000, based on the average bulk fluid temperature was tested at annular diameter ratios of 0.327, 0.386, 0.409 and 0.483 with hydraulic diameters of 17.00, 22.98, 20.20 and 26.18 mm respectively. Both heated and cooled annuli were investigated by conducting tests at a range of inlet temperatures between 10 °C to 30 °C for heating cases, and 30 °C to 50 °C for cooling cases. Of special interest was the direct measurement of local wall temperatures on the heat transfer surface, which is often difficult to obtain and evasive in data-sets. Continuous verification and re-evaluation of temperatures measurements were performed via in-situ calibration. It is shown that inlet fluid temperature and the heat transfer direction play significant roles on the magnitude of the heat transfer coefficient. A new adjusted Colburn j-factor definition is presented to describe the heating and cooling cases and is used to correlate the 894 test cases considered in this study.
MULTI-SCALE MODELING AND APPROXIMATION ASSISTED OPTIMIZATION OF BARE TUBE HEAT EXCHANGERS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bacellar, Daniel; Ling, Jiazhen; Aute, Vikrant
2014-01-01
Air-to-refrigerant heat exchangers are very common in air-conditioning, heat pump and refrigeration applications. In these heat exchangers, there is a great benefit in terms of size, weight, refrigerant charge and heat transfer coefficient, by moving from conventional channel sizes (~ 9mm) to smaller channel sizes (< 5mm). This work investigates new designs for air-to-refrigerant heat exchangers with tube outer diameter ranging from 0.5 to 2.0mm. The goal of this research is to develop and optimize the design of these heat exchangers and compare their performance with existing state of the art designs. The air-side performance of various tube bundle configurationsmore » are analyzed using a Parallel Parameterized CFD (PPCFD) technique. PPCFD allows for fast-parametric CFD analyses of various geometries with topology change. Approximation techniques drastically reduce the number of CFD evaluations required during optimization. Maximum Entropy Design method is used for sampling and Kriging method is used for metamodeling. Metamodels are developed for the air-side heat transfer coefficients and pressure drop as a function of tube-bundle dimensions and air velocity. The metamodels are then integrated with an air-to-refrigerant heat exchanger design code. This integration allows a multi-scale analysis of air-side performance heat exchangers including air-to-refrigerant heat transfer and phase change. Overall optimization is carried out using a multi-objective genetic algorithm. The optimal designs found can exhibit 50 percent size reduction, 75 percent decrease in air side pressure drop and doubled air heat transfer coefficients compared to a high performance compact micro channel heat exchanger with same capacity and flow rates.« less
Adsorption of multilamellar tubes with a temperature tunable diameter at the air/water interface.
Fameau, Anne-Laure; Douliez, Jean-Paul; Boué, François; Ott, Frédéric; Cousin, Fabrice
2011-10-15
The ethanolamine salt of 12-hydroxy stearic acid is known to form tubes having a temperature tunable diameter. Here, we study the behavior of those tubes at the air/water interface by using Neutron Reflectivity. We observed that tubes indeed adsorbed at this interface below a fatty acid monolayer and exhibit the same temperature behavior as in bulk. There is however a peculiar behavior at around 50 °C for which the increase of the diameter of the tubes at the interface yields an unfolding of those tubes into a multilamellar layer. Upon further heating, the tubes re-fold and their diameter re-decreases after which they melt into micelles as observed in the bulk. All structural transitions at the interface are nevertheless reversible. This provides to the system a high interest for its interfacial properties because the structure at the air/water interface can be tuned easily by the temperature. Copyright © 2011 Elsevier Inc. All rights reserved.
Rodríguez-Ruiz, A; Castillo, M; Garayoa, J; Chevalier, M
2016-06-01
The aim of this work was to research and evaluate the performance of three different digital breast tomosynthesis (DBT) systems in the clinical environment (Siemens Mammomat Inspiration, Hologic Selenia Dimensions, and Fujifilm Amulet Innovality). The characterization included the study of the detector, the automatic exposure control, and the resolution of DBT projections and reconstructed planes. The modulation transfer function (MTF) of the DBT projections was measured with a 1mm thick steel edge, showing a strong anisotropy (30-40% lower MTF0.5 frequencies in the tube travel direction). The in-plane MTF0.5, measured with a 25μm tungsten wire, ranges from 1.3 to 1.8lp/mm in the tube-travel direction and between 2.4 and 3.7lp/mm in the chest wall-nipple. In the latter direction, the MTF peak shift is more emphasized for large angular range systems (2.0 versus 1.0lp/mm). In-depth resolution of the planes, via the full width at half maximum (FWHM) from the point spread function of a 25μm tungsten wire, is not only influenced by angular range and yields 1.3-4.6mm among systems. The artifact spread function from 1mm diameter tungsten beads depends mainly on angular range, yielding two tendencies whether large (FWHM is 4.5mm) or small (FWHM is 10mm) angular range is used. DBT delivers per scan a mean glandular dose between 1.4 and 2.7mGy for a 45mm thick polymethyl methacrylate (PMMA) block. In conclusion, we have identified and analysed specific metrics that can be used for quality assurance of DBT systems. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Glukhova, O. E.; Slepchenkov, M. M.
2016-03-01
Using hybrid quantum mechanics/molecular mechanics (QM/MM) model we carried out investigation of interaction between phospholipid and carbon nanotube during indentation of high density lipoprotein (HDL). The object of investigation is armchair carbon nanotube with various diameters range from 0.5 to 1 nm. In a coarse of molecular dynamics study it is found that phospholipid partially penetrate into the cavity of nanotube with the chirality (7,7) and diameter of 0.9 nm. However, the entire molecule does not fit into nanospace of tube (7,7), so part of the head and the second phospholipid tail remain outside the carbon nanostructures. Using semi-empirical PM6 method it is established that during the indentation process the charged structured molecule fragments forming the high-density lipoprotein create local electric field near carbon nanotube (CNT) and continuously change electronic structure of CNT. However, the tube is not destroyed because the fields do not exceed the critical values of strength. The redistribution of the electron density on atom is observed in each time point.
High-frequency ultrasound Doppler system for biomedical applications with a 30-MHz linear array.
Xu, Xiaochen; Sun, Lei; Cannata, Jonathan M; Yen, Jesse T; Shung, K Kirk
2008-04-01
In this paper, we report the development of the first high-frequency (HF) pulsed-wave Doppler system using a 30-MHz linear array transducer to assess the cardiovascular functions in small animals. This array-based pulsed-wave Doppler system included a 16-channel HF analog beamformer, a HF pulsed-wave Doppler module, timing circuits, HF bipolar pulsers and analog front ends. The beamformed echoes acquired by the 16-channel analog beamformer were fed directly to the HF pulsed-wave Doppler module. Then the in-phase and quadrature-phase (IQ) audio Doppler signals were digitized by either a sound card or a Gage digitizer and stored in a personal computer. The Doppler spectrogram was displayed on a personal computer in real time. The two-way beamwidths were determined to be 160 microm to 320 microm when the array was electronically focused at different focal points at depths from 5 to 10 mm. A micro-flow phantom, consisting of a polyimide tube with an inner diameter of 127 microm and the wire phantom were used to evaluate and calibrate the system. The results show that the system is capable of detecting motion velocity of the wire phantom as low as 0.1 mm/s, and detecting blood-mimicking flow velocity in the 127-microm tube lower than 7 mm/s. The system was subsequently used to measure the blood flow in vivo in two mouse abdominal superficial vessels, with diameters of approximately 200 microm, and a mouse aorta close to the heart. These results demonstrated that this system may become an indispensable part of the current HF array-based imaging systems for small animal studies.
[Experimental study of an intratracheal stent made of shape memory alloy].
Yoshimura, M; Tsugawa, C; Tsubota, N
1994-11-01
To develop a new prosthesis for treating tracheal stenosis and tracheobronchomalacia, we examined the usefulness of an intratracheal stent made of shape memory alloy (SMA), a titanium-nickel alloy composed of 50% of each metal. At its recovery temperature (37 degrees C), the SMA stent was designed to recall the memorized shape of a coil with a diameter of 5 or 6 mm and a length of 10 mm. For the present experiment, it was transformed to a smaller coil 3 mm in diameter at a low temperature (-50 degrees C) and then loaded into the prosthesis introducer tube. An experimental model of potentially fatal tracheomalacia was made surgically by cutting and fracturing the tracheal cartilages of rabbits and tracheal collapse was confirmed by rigid bronchoscope. The introducer tube with the SMA stent was inserted and then the prosthesis was advanced into the collapsed segment of the trachea using the stent pusher. The SMA stent warmed bo body temperature and recovered its memorized shape after 1-2 min. In 3 out of 8 rabbits, follow-up bronchoscopy performed at 6, 8, and 10 months after implantation revealed satisfactory patency of the SMA stent and the trachea. After follow-up, 3 animals were sacrificed for histological observation, which showed little proliferation of granulation tissue and no dislocation of the SMA stent from the malacic portion. The remaining 5 rabbits have been followed for 18-24 months and are doing well. We conclude that the SMA stent maintains good tracheal patency, causes little reaction in the tracheal wall, and is easy to handle. Thus, it shows the potential for clinical application.
A Contaminant Ice Visualization Experiment in a Glass Pulse Tube
NASA Technical Reports Server (NTRS)
Hall, J. L.; Ross, R. G., Jr.; Le, A. K.
2000-01-01
Results are presented from pulse tube experiments designed to investigate the effect of 400 parts per million water vapor contamination of the helium working gas. The experiments were conducted in a glass pulse tube to enable visualization of ice formation on internal surfaces. Photographs of this ice formation were taken along with simultaneous coldtip temperature and compressor power measurements. Four types of regenerator elements were tested in various combinations: 200- and 400-mesh stainless steel screens, 1.6 mm diameter glass beads, and 1.6 mm thick perforated plastic plates. Internal spacers were also used to provide clear fields of view into the regenerator stack. Substantial water-ice formation was observed at the cold end of the regenerator and on the inside wall of pulse tube; it appeared to be highly porous, like snow, and was seen to accumulate only in a very localized region at the coldest end, despite changing the cold tip temperature across a range of 150 to 235 K. Ice formation degraded pulse tube thermal performance only in cases where screen regenerators were used at the regenerator cold end. It was concluded that flow blockage was the mechanism by which contaminants affected performance; coarse regenerator elements were largely immune over the tested time scale of a few days. Substantially reduced ice formation and minimal performance loss were also observed in repeated tests where the contaminated gas was reused after warming up and melting of the accumulated internal ice. Significant adsorption of the liquid water onto the regenerator was inferred, a process that depleted the gas phase concentration of water.
NASA Astrophysics Data System (ADS)
Rollmann, P.; Spindler, K.; Müller-Steinhagen, H.
2011-08-01
The heat transfer, pressure drop and flow patterns during flow boiling of R407C in a horizontal microfin tube have been investigated. The microfin tube is made of copper with a total fin number of 55 and a helix angle of 15°. The fin height is 0.24 mm and the inner tube diameter at fin root is 8.95 mm. The test tube is 1 m long. It is heated electrically. The experiments have been performed at saturation temperatures between -30°C and +10°C. The mass flux was varied between 25 and 300 kg/m2/s, the heat flux from 20,000 W/m2 down to 1,000 W/m2. The vapour quality was kept constant at 0.1, 0.3, 0.5, 0.7 at the inlet and 0.8, 1.0 at the outlet, respectively. The measured heat transfer coefficient is compared with the correlations of Cavallini et al., Shah as well as Zhang et al. Cavallini's correlation contains seven experimental constants. After fitting these constants to our measured values, the correlation achieves good agreement. The measured pressure drop is compared to the correlations of Pierre, Kuo and Wang as well as Müller-Steinhagen and Heck. The best agreement is achieved with the correlation of Kuo and Wang. Almost all values are calculated within an accuracy of ±30%. The flow regimes were observed. It is shown, that changes in the flow regime affect the heat transfer coefficient significantly.
[Laparoscopic choledochoscopy].
Alecu, L; Marin, A; Corodeanu, Gh; Gulinescu, L
2003-01-01
Of this study was to evaluate the treatment of common bile duct stones (CBDS) by laparoscopic choledochoscopy. Between 1997-2002, 9 patients (with age between 42-75 years) were treated laparoscopic for CBDS: 8 cases with choledocholithiasis; 1 case with pancreatic neoplasm. Laparoscopic choledochoscopy was performed in 7 cases (84.4%). We used the choledochoscope Pentax of 5 mm diameter and with work canal. We performed the CBD exploration with: transcystic approach-1 case; choledochotomy-6 cases. The CBD diameter was between 1.2-1.5 cm. The bile duct stones diameter were between 0.5-1.5 cm. We performed with successfully the laparoscopic choledochoscopy exploration and extraction of CBD stones to all patients. External biliary drainage (transcystic duct and with Kehr-tube) were done systematically. The major complication (choleperitoneum) occurred in 2 cases (28.5%). The occurrence of residual ductal stones was 0. The laparoscopic treatment of choledocholithiasis is feasible, safe and efficient.
Ahadi, Zohreh; Shadman, Muhammad; Yeganegi, Saeed; Asgari, Farid
2012-07-01
Hydrogen adsorption in multi-walled boron nitride nanotubes and their arrays was studied using grand canonical Monte Carlo simulation. The results show that hydrogen storage increases with tube diameter and the distance between the tubes in multi-walled boron nitride nanotube arrays. Also, triple-walled boron nitride nanotubes present the lowest level of hydrogen physisorption, double-walled boron nitride nanotubes adsorb hydrogen better when the diameter of the inner tube diameter is sufficiently large, and single-walled boron nitride nanotubes adsorb hydrogen well when the tube diameter is small enough. Boron nitride nanotube arrays adsorb hydrogen, but the percentage of adsorbed hydrogen (by weight) in boron nitride nanotube arrays is rather similar to that found in multi-walled boron nitride nanotubes. Also, when the Langmuir and Langmuir-Freundlich equations were fitted to the simulated data, it was found that multi-layer adsorptivity occurs more prominently as the number of walls and the tube diameter increase. However, in single-walled boron nitride nanotubes with a small diameter, the dominant mechanism is monolayer adsorptivity.
Quasi-static axial crushes on woven jute/polyester AA6063T52 composite tubes
NASA Astrophysics Data System (ADS)
Othman, A.; Ismail, AE
2018-04-01
Quasi-static axial loading have been studied in this paper to determine the behaviour of jute/polyester wrapped on aluminium alloy 6063T52. The filler material also was include into crush box specimen, which is polyurethane (PU) and polystyrene (PE) rigid foam at ranging 40 and 45 kg/m3 densities. All specimen profile was fabricated using hand layup techniques and the length of each specimen were fixed at 100 mm as well as diameter and width of the tube at 50.8 mm. The two types of tubular cross-section were studied of round and square thin-walled profiles and the angle of fibre at 450 were analysed for four layers. Thin walled of aluminium was 1.9 mm and end frontal of each specimen of composite were chamfered at 450 to prevent catastrophic failure mode. The specific absorbed energy (SEA) and crush force efficiency (CFE) were analyses for each specimen to see the behaviour on jute/polyester wrapped on metallic structure can give influence the energy management for automotive application. Result show that the four layers’ jute/polyester with filler material show significant value in term of specific absorbed energy compared empty and polyurethane profiles higher 26.66% for empty and 15.19% compared to polyurethane profiles. It has been found that the thin walled square profile of the jute/polyester tubes with polystyrene foam-filled is found higher respectively 27.42% to 13.13% than empty and polyurethane (PU) foam tubes. An introduce filler material onto thin walled composite profiles gave major advantage increases the mean axial load of 31.87% from 32.94 kN to 48.35 kN from empty to polystyrene thin walled round jute/polyester profiles and 31.7% from 23.11 KN to 33.84 kN from empty to polystyrene thin walled square jute/polyester profiles. Failure mechanisms of the axially loaded composite tubes were also observed and discussed.
Li, Xiang; Samei, Ehsan; Barnhart, Huiman X; Gaca, Ana Maria; Hollingsworth, Caroline L; Maxfield, Charles M; Carrico, Caroline W T; Colsher, James G; Frush, Donald P
2011-05-01
To determine the quantitative relationship between image quality and radiologist performance in detecting small lung nodules in pediatric CT. The study included clinical chest CT images of 30 pediatric patients (0-16 years) scanned at tube currents of 55-180 mA. Calibrated noise addition software was used to simulate cases at three nominal mA settings: 70, 35, and 17.5 mA, resulting in quantum noise of 7-32 Hounsfield Unit (HU). Using a validated nodule simulation technique, lung nodules with diameters of 3-5 mm and peak contrasts of 200-500 HU were inserted into the cases, which were then randomized and rated independently by four experienced pediatric radiologists for nodule presence on a continuous scale from 0 (definitely absent) to 100 (definitely present). The receiver operating characteristic (ROC) data were analyzed to quantify the relationship between diagnostic accuracy (area under the ROC curve, AUC) and image quality (the product of nodule peak contrast and displayed diameter to noise ratio, CDNR display). AUC increased rapidly from 0.70 to 0.87 when CDNR display increased from 60 to 130 mm, followed by a slow increase to 0.94 when CDNR display further increased to 257 mm. For the average nodule diameter (4 mm) and contrast (350 HU), AUC decreased from 0.93 to 0.71 with noise increased from 7 to 28 HU. We quantified the relationship between image quality and the performance of radiologists in detecting lung nodules in pediatric CT. The relationship can guide CT protocol design to achieve the desired diagnostic performance at the lowest radiation dose.
Fabrication of multifilamentary Nb/sub 3/(Al,Ge) wires through a modified jelly roll process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tachikawa, K.; Kamisada, Y.; Suzuki, E.
Recently, development of Nb/sub 3/Al multifilamentary wires has gained much interests since high-field performance superior to that of Nb/sub 3/Sn can be expected in these wires. In this study, Nb/Al-Ge alloy composites were fabricated into multifilamentary wires through a modified jelly roll (MJR) process. A Nb mesh sheet produced at the Teledyne Wah Chang Co. was used as Nb component. An Al-Ge alloy prepared by a conventional casting process was forged and rolled into a sheet of 0.2 mm in thickness. The Nb/Al-Ge composite was prepared by wrapping the Nb mesh sheet together with the Al-Ge alloy sheet around amore » Nb core into a jelly roll form. The MJR composite was encased in a Cu-Ni alloy tube of which outer diameter was 43 mm. The resulting composite was hydrostatically pressed and extruded into a rod of 18 mm in diameter. A Nb barrier was then inserted between the MJR and the Cu-Ni jacket. The composite rod was swaged and drawn into a wire without any intermediate annealing. The wire was able to be drawn down to a very small diameter of 0.1 mm. The cross-sectional configuration of the MJR composite was not much disturbed by the fabrication. Superconducting transition temperature Tc of the wire, after different heat treatment including a rapid quenching from high temperatures by a continuous electron beam irradiation, was studied, and an onset Tc of 19.3K has been achieved.« less
Nitinol: Tubing versus sputtered film - microcleanliness and corrosion behavior.
Wohlschlögel, Markus; Lima de Miranda, Rodrigo; Schüßler, Andreas; Quandt, Eckhard
2016-08-01
Corrosion behavior and microcleanliness of medical-device grade Nitinol tubing (Nix Ti1- x , x = 0.51; outer diameter 7 mm, wall thickness 0.5 mm), drawn from various ingot qualities, are compared to the characteristics of sputtered Nitinol film material (Nix Ti1- x , x = 0.51; thickness 50 µm). Electropolished tubing half-shell samples are tested versus as-received sputtered film samples. Inclusion size distributions are assessed using quantitative metallography and corrosion behavior is investigated by potentiodynamic polarization testing in phosphate-buffered saline at body temperature. For the sputtered film samples, the surface chemistry is additionally analyzed employing Auger Electron Spectroscopy (AES) composition-depth profiling. Results show that the fraction of breakdowns in the potentiodynamic polarization test correlates with number and size of the inclusions in the material. For the sputtered Nitinol film material no inclusions were detectable by light microscopy on the one hand and no breakdowns were found in the potentiodynamic polarization test on the other hand. As for electropolished Nitinol, the sputtered Nitinol film material reveals Nickel depletion and an Oxygen-to-Titanium intensity ratio of ∼2:1 in the surface oxide layer, as measured by AES. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1176-1181, 2016. © 2015 Wiley Periodicals, Inc.
R1234yf vs. R134a Flow Boiling Heat Transfer Inside a 3.4 mm ID Microfin Tube
NASA Astrophysics Data System (ADS)
Diani, A.; Mancin, S.; Rossetto, L.
2014-11-01
The refrigerant charge minimization as well as the use of eco-friendly fluids can be considered two of the most important targets for these applications to cope with the new environmental challenges. This paper compares the R1234yf and R134a flow boiling heat transfer and pressure drop measurements inside a small microfin tube with internal diameter at the fin tip of 3.4 mm. This study is carried out in an experimental facility built at the Dipartimento di Ingegneria Industriale of the University of Padova especially designed to study both single and two phase heat transfer processes. The microfin tube is brazed inside a copper plate and electrically heated from the bottom. Several T -type thermocouples are inserted in the wall to measure the temperature distribution during the phase change process. In particular, the experimental measurements were carried out at constant saturation temperature of 30 °C, by varying the refrigerant mass velocity between 190 kg m-2 s-1 and 940 kg m-2 s-1, the vapour quality from 0.2 to 0.99, at different imposed heat fluxes. The two refrigerants are compared considering the values of the two-phase heat transfer coefficient and pressure drop.
Hutchens, Thomas C; Gonzalez, David A; Irby, Pierce B; Fried, Nathaniel M
2017-01-01
The experimental thulium fiber laser (TFL) is being explored as an alternative to the current clinical gold standard Holmium:YAG laser for lithotripsy. The near single-mode TFL beam allows coupling of higher power into smaller optical fibers than the multimode Holmium laser beam profile, without proximal fiber tip degradation. A smaller fiber is desirable because it provides more space in the ureteroscope working channel for increased saline irrigation rates and allows maximum ureteroscope deflection. However, distal fiber tip burnback increases as fiber diameter decreases. Previous studies utilizing hollow steel sheaths around recessed distal fiber tips reduced fiber burnback but increased stone retropulsion. A “fiber muzzle brake” was tested for reducing both fiber burnback and stone retropulsion by manipulating vapor bubble expansion. TFL lithotripsy studies were performed at 1908 nm, 35 mJ, 500 ?? ? s , and 300 Hz using a 100 - ? m -core fiber. The optimal stainless steel muzzle brake tip tested consisted of a 1-cm-long, 560 - ? m -outer-diameter, 360 - ? m -inner-diameter tube with a 275 - ? m -diameter through hole located 250 ?? ? m from the distal end. The fiber tip was recessed a distance of 500 ?? ? m . Stone phantom retropulsion, fiber tip burnback, and calcium oxalate stone ablation studies were performed ex vivo. Small stones with a mass of 40 ± 4 ?? mg and 4-mm-diameter were ablated over a 1.5-mm sieve in 25 ± 4 ?? s
High-definition computed tomography for coronary artery stent imaging: a phantom study.
Yang, Wen Jie; Chen, Ke Min; Pang, Li Fang; Guo, Ying; Li, Jian Ying; Zhang, Huang; Pan, Zi Lai
2012-01-01
To assess the performance of a high-definition CT (HDCT) for imaging small caliber coronary stents (≤ 3 mm) by comparing different scan modes of a conventional 64-row standard-definition CT (SDCT). A cardiac phantom with twelve stents (2.5 mm and 3.0 mm in diameter) was scanned by HDCT and SDCT. The scan modes were retrospective electrocardiography (ECG)-gated helical and prospective ECG-triggered axial with tube voltages of 120 kVp and 100 kVp, respectively. The inner stent diameters (ISD) and the in-stent attenuation value (AV(in-stent)) and the in-vessel extra-stent attenuation value (AV(in-vessel)) were measured by two observers. The artificial lumen narrowing (ALN = [ISD - ISD(measured)]/ISD) and artificial attenuation increase between in-stent and in-vessel (AAI = AV(in-stent) - AV(in-vessel)) were calculated. All data was analyzed by intraclass correlation and ANOVA-test. The correlation coefficient of ISD, AV(in-vessel) and AV(in-stent) between the two observers was good. The ALNs of HDCT were statistically lower than that of SDCT (30 ± 5.7% versus 35 ± 5.4%, p < 0.05). HDCT had statistically lower AAI values than SDCT (15.7 ± 81.4 HU versus 71.4 ± 90.5 HU, p < 0.05). The prospective axial dataset demonstrated smaller ALN than the retrospective helical dataset on both HDCT and SDCT (p < 0.05). Additionally, there were no differences in ALN between the 120 kVp and 100 kVp tube voltages on HDCT (p = 0.05). High-definition CT helps improve measurement accuracy for imaging coronary stents compared to SDCT. HDCT with 100 kVp and the prospective ECG-triggered axial technique, with a lower radiation dose than 120 kVp application, may be advantageous in evaluating coronary stents with smaller calibers (≤ 3 mm).
On-Chip Microfluidic Components for In Situ Analysis, Separation, and Detection of Amino Acids
NASA Technical Reports Server (NTRS)
Zheng, Yun; Getty, Stephanie; Dworkin, Jason; Balvin, Manuel; Kotecki, Carl
2013-01-01
The Astrobiology Analytical Laboratory at GSFC has identified amino acids in meteorites and returned cometary samples by using liquid chromatography-electrospray ionization time-of-flight mass spectrometry (LCMS). These organic species are key markers for life, having the property of chirality that can be used to distinguish biological from non-biological amino acids. One of the critical components in the benchtop instrument is liquid chromatography (LC) analytical column. The commercial LC analytical column is an over- 250-mm-long and 4.6-mm-diameter stainless steel tube filled with functionized microbeads as stationary phase to separate the molecular species based on their chemistry. Miniaturization of this technique for spaceflight is compelling for future payloads for landed missions targeting astrobiology objectives. A commercial liquid chromatography analytical column consists of an inert cylindrical tube filled with a stationary phase, i.e., microbeads, that has been functionalized with a targeted chemistry. When analyte is sent through the column by a pressurized carrier fluid (typically a methanol/ water mixture), compounds are separated in time due to differences in chemical interactions with the stationary phase. Different species of analyte molecules will interact more strongly with the column chemistry, and will therefore take longer to traverse the column. In this way, the column will separate molecular species based on their chemistry. A lab-on-chip liquid analysis tool was developed. The microfluidic analytical column is capable of chromatographically separating biologically relevant classes of molecules based on their chemistry. For this analytical column, fabrication, low leak rate, and stationary phase incorporation of a serpentine microchannel were demonstrated that mimic the dimensions of a commercial LC column within a 5 10 1 mm chip. The microchannel in the chip has a 75- micrometer-diameter oval-shaped cross section. The serpentine microchannel has four different lengths: 40, 60, 80, and 100 mm. Functionized microbeads were filled inside the microchannel to separate molecular species based on their chemistry.
Parametric Investigation of Thrust Augmentation by Ejectors on a Pulsed Detonation Tube
NASA Technical Reports Server (NTRS)
Wilson, Jack; Sgondea, Alexandru; Paxson, Daniel E.; Rosenthal, Bruce N.
2006-01-01
A parametric investigation has been made of thrust augmentation of a 1 in. diameter pulsed detonation tube by ejectors. A set of ejectors was used which permitted variation of the ejector length, diameter, and nose radius, according to a statistical design of experiment scheme. The maximum augmentation ratios for each ejector were fitted using a polynomial response surface, from which the optimum ratios of ejector diameter to detonation tube diameter, and ejector length and nose radius to ejector diameter, were found. Thrust augmentation ratios above a factor of 2 were measured. In these tests, the pulsed detonation device was run on approximately stoichiometric air-hydrogen mixtures, at a frequency of 20 Hz. Later measurements at a frequency of 40 Hz gave lower values of thrust augmentation. Measurements of thrust augmentation as a function of ejector entrance to detonation tube exit distance showed two maxima, one with the ejector entrance upstream, and one downstream, of the detonation tube exit. A thrust augmentation of 2.5 was observed using a tapered ejector.
Li, Yanfeng; Wang, Fuli; Hu, Pin; Fan, Jiadong; Han, Yishi; Liu, Bin; Liu, Tao; Yang, Chunhao; Gu, Xiangmin
2016-01-01
Osteotome sinus floor elevation is a less invasive approach to augment an insufficient alveolar bone at the posterior maxilla for dental implantation. However, this approach has some limitations due to the lack of sinus lift tools available for clinical use and the small transcrestal access to the maxillary sinus floor. We recently invented shape-memory Ni/Ti alloy wire containing tube elevators for transcrestal detaching maxillary sinus mucosa, and developed goat ex vivo models for direct visualizing the effectiveness of detaching sinus mucosa in real time during transcrestal maxillary sinus floor elevation. We evaluated our invented elevators, namely elevator 012 and elevator 014, for their effectiveness for transcrestal detaching maxillary sinus mucosa using the goat ex vivo models. We measured the length of sinus mucosa detached in mesial and distal directions or buccal and palatal directions, and the space volume created by detaching maxillary sinus mucosa in mesial, distal, buccal and palatal directions using the invented elevators. Elevator 012 had a shape-memory Ni/Ti alloy wire with a diameter of 0.012 inch, while elevator 014 had its shape-memory Ni/Ti alloy wire with a diameter of 0.014 inch. Elevator 012 could detach the goat maxillary sinus mucosa in the mesial or distal direction for 12.1±4.3 mm, while in the buccal or palatal direction for 12.5±6.7 mm. The elevator 014 could detach the goat maxillary sinus mucosa for 23.0±4.9 mm in the mesial or distal direction, and for 19.0±8.1 mm in the buccal or palatal direction. An average space volume of 1.7936±0.2079 ml was created after detaching the goat maxillay sinus mucosa in both mesial/distal direction and buccal/palatal direction using elevator 012; while the average space volume created using elevator 014 was 1.8764±0.2366 ml. Both two newly invented tube elevators could effectively detach the maxillary sinus mucosa on the goat ex vivo sinus models. Moreover, elevator 014 has advantages over the elevator 012 for the capability to detach sinus mucosa. © 2016 The Author(s) Published by S. Karger AG, Basel.
Rechargeable biofilm-controlling tubing materials for use in dental unit water lines.
Luo, Jie; Porteous, Nuala; Sun, Yuyu
2011-08-01
A simple and practical surface grafting approach was developed to introduce rechargeable N-halamine-based antimicrobial functionality onto the inner surfaces of continuous small-bore polyurethane (PU) dental unit waterline (DUWL) tubing. In this approach, tetrahydrofuran (THF) solution of a free-radical initiator, dicumyl peroxide (DCP), flowed through the PU tubing (inner diameter of 1/16 in., or 1.6 mm) to diffuse DCP into the tubing's inner walls, which was used as initiator in the subsequent grafting polymerization of methacrylamide (MAA) onto the tubing. Upon chlorine bleach treatment, the amide groups of the grafted MAA side chains were transformed into acyclic N-halamines. The reactions were confirmed with attenuated total reflectance infrared (ATR) spectra and iodometric titration. The mechanical properties of the tubing were not significantly affected by the grafting reactions. The biofilm-controlling function of the new N-halamine-based PU tubing was evaluated with Pseudomonas aeruginosa (P. aeruginosa), one of the most isolated water bacteria from DUWLs, in a continuous bacterial flow model. Bacteria culturing and SEM studies showed that the inner surfaces of the new N-halamine-based PU tubing completely prevented bacterial biofilm formation for at least three to four weeks. After that, bacteria began to colonize the tubing surface. However, the lost function was fully regenerated by exposing the tubing inner surfaces to diluted chlorine bleach. The recharging process could be repeated periodically to further extend the biofilm-controlling duration for long-term applications.
Shibao, Shunsuke; Toda, Masahiro; Tomita, Toshiki; Saito, Katsuya; Ogawa, Kaoru; Kawase, Takeshi; Yoshida, Kazunari
2015-01-01
Recently, petrous apex cholesterol granulomas (CGs) have been treated via the endoscopic endonasal transsphenoidal approach (EEA) using a silicone tube, to prevent drainage route occlusion. Occlusion of the drainage route has led to problems with recurrence. The aim of this report is to describe the use of a surgical technique to prevent drainage route occlusion. In surgical technique, the posterolateral wall of the sphenoid sinus was opened by EEA. After cyst debridement, a vascularized nasoseptal flap with a width of approximately 4 cm was inserted into the lumen with a silicone T-tube with a diameter of 7 mm. This technique was used in two patients: the first patient during the second operation after recurrence following occlusion of the drainage route, and the second patient during the first operation. Opening of the cyst wall was confirmed endoscopically in both patients 12-24 months after surgery, even after removal of the T-tube. In conclusion, the use of a pedicled nasoseptal flap with a silicone tube is useful to prevent CG recurrence, by paranasal cavitization of the cystic cavity.
NASA Astrophysics Data System (ADS)
Qasim, S. M.; Sahar, A. F. A.; Firas, A. A.
2015-11-01
A numerical study has been carried out to investigate the heat transfer by laminar forced convection of nanofluid taking Titania (TiO2) and Alumina (Al2O3) as nanoparticles and the water as based fluid in a three dimensional plain and U-longitudinal finned tube heat exchanger. A Solid WORKS PREMIUM 2012 is used to draw the geometries of plain tube heat exchanger or U-longitudinal copper finned tube heat exchanger. Four U-longitudinal copper fins have 100 cm long, 3.8cm height and 1mm thickness are attached to a straight copper tube of 100 cm length, 2.2 cm inner diameter and 2.39 cm outer diameter. The governing equations which used as continuity, momentum and energy equations under assumptions are utilized to predict the flow field, temperature distribution, and heat transfer of the heat exchanger. The finite volume approach is used to obtain all the computational results using commercial ANSYS Fluent copy package 14.0 with assist of solid works and Gambit software program. The effect of various parameters on the performance of heat exchanger are investigated numerically such as Reynolds' number (ranging from 270 to 1900), volume consternation of nanoparticles (0.2%, 0.4%, 0.6%, 0.8%), type of nanoparticles, and mass flow rate of nanofluid in the hot region of heat exchanger. For 0.8% consternation of nanoparticles, heat transfer has significant enhancement in both nanofluids. It can be found about 7.3% for TiO2 and about 7.5% for Al2O3 compared with the water only as a working fluid.
High frequency pressure oscillator for microcryocoolers.
Vanapalli, S; ter Brake, H J M; Jansen, H V; Zhao, Y; Holland, H J; Burger, J F; Elwenspoek, M C
2008-04-01
Microminiature pulse tube cryocoolers should operate at a frequency of an order higher than the conventional macro ones because the pulse tube cryocooler operating frequency scales inversely with the square of the pulse tube diameter. In this paper, the design and experiments of a high frequency pressure oscillator is presented with the aim to power a micropulse tube cryocooler operating between 300 and 80 K, delivering a cooling power of 10 mW. Piezoelectric actuators operate efficiently at high frequencies and have high power density making them good candidates as drivers for high frequency pressure oscillator. The pressure oscillator described in this work consists of a membrane driven by a piezoelectric actuator. A pressure ratio of about 1.11 was achieved with a filling pressure of 2.5 MPa and compression volume of about 22.6 mm(3) when operating the actuator with a peak-to-peak sinusoidal voltage of 100 V at a frequency of 1 kHz. The electrical power input was 2.73 W. The high pressure ratio and low electrical input power at high frequencies would herald development of microminiature cryocoolers.
High frequency pressure oscillator for microcryocoolers
NASA Astrophysics Data System (ADS)
Vanapalli, S.; ter Brake, H. J. M.; Jansen, H. V.; Zhao, Y.; Holland, H. J.; Burger, J. F.; Elwenspoek, M. C.
2008-04-01
Microminiature pulse tube cryocoolers should operate at a frequency of an order higher than the conventional macro ones because the pulse tube cryocooler operating frequency scales inversely with the square of the pulse tube diameter. In this paper, the design and experiments of a high frequency pressure oscillator is presented with the aim to power a micropulse tube cryocooler operating between 300 and 80K, delivering a cooling power of 10mW. Piezoelectric actuators operate efficiently at high frequencies and have high power density making them good candidates as drivers for high frequency pressure oscillator. The pressure oscillator described in this work consists of a membrane driven by a piezoelectric actuator. A pressure ratio of about 1.11 was achieved with a filling pressure of 2.5MPa and compression volume of about 22.6mm3 when operating the actuator with a peak-to-peak sinusoidal voltage of 100V at a frequency of 1kHz. The electrical power input was 2.73W. The high pressure ratio and low electrical input power at high frequencies would herald development of microminiature cryocoolers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Jing; Chen, Di; Wang, Xuemei
2015-10-12
Ion irradiation effects on thermal property changes are compared between aligned carbon nanotube (A-CNT) films and randomly entangled carbon nanotube (R-CNT) films. After H, C, and Fe ion irradiation, a focusing ion beam with sub-mm diameter is used as a heating source, and an infrared signal is recorded to extract thermal conductivity. Ion irradiation decreases thermal conductivity of A-CNT films, but increases that of R-CNT films. We explain the opposite trends by the fact that neighboring CNT bundles are loosely bonded in A-CNT films, which makes it difficult to create inter-tube linkage/bonding upon ion irradiation. In a comparison, in R-CNTmore » films, which have dense tube networking, carbon displacements are easily trapped between touching tubes and act as inter-tube linkage to promote off-axial phonon transport. The enhancement overcomes the phonon transport loss due to phonon-defect scattering along the axial direction. A model is established to explain the dependence of thermal conductivity changes on ion irradiation parameters including ion species, energies, and current.« less
On the Opening of Thick Walled Elastic Tubes: A Fluid-Structure Model for Acid Reflux
NASA Astrophysics Data System (ADS)
Ghosh, Sudip; Kahrilas, Peter
2005-11-01
A coupled fluid-structure mathematical model was developed to quantify rapid opening of thick-walled elastic tubes, a phenomenon underlying biological flows such as gastroesophageal reflux disease (GERD). The wall was modeled using non-linear finite deformation theory to predict space-time radial distention of an axisymmetric tube with luminal fluid flow. Anisotropic azimuthal and longitudinal muscle-induced stresses were incorporated, and interstitial material properties were assumed isotropic and linearly elastic. Fluid flow was modeled using lubrication theory with inertial correction. Opening and flow were driven by a specified inflow pressure and zero pressure gradient was specified at outflow. No-slip and surface force balance were applied at the fluid-wall interface. Viscoelasticity was modeled with ad hoc damping and the evolution of the tube geometry was predicted at mid-layer. A potentially important discovery was made when applied to studies of initiation of opening with GERD: while material stiffness is of minor consequence, small changes in resting lumen distension (˜2 mm diameter) may be a sensitive distinguishing feature of the disease.
Behavior of turbulent gas jets in an axisymmetric confinement
NASA Technical Reports Server (NTRS)
So, R. M. C.; Ahmed, S. A.
1985-01-01
The understanding of the mixing of confined turbulent jets of different densities with air is of great importance to many industrial applications, such as gas turbine and Ramjet combustors. Although there have been numerous studies on the characteristics of free gas jets, little is known of the behavior of gas jets in a confinement. The jet, with a diameter of 8.73 mm, is aligned concentrically in a tube of 125 mm diameter, thus giving a confinement ratio of approximately 205. The arrangement forms part of the test section of an open-jet wind tunnel. Experiments are carried out with carbon dioxide, air and helium/air jets at different jet velocities. Mean velocity and turbulence measurements are made with a one-color, one-component laser Doppler velocimeter operating in the forward scatter mode. Measurements show that the jets are highly dissipative. Consequently, equilibrium jet characteristics similar to those found in free air jets are observed in the first two diameters downstream of the jet. These results are independent of the fluid densities and velocities. Decay of the jet, on the other hand, is a function of both the jet fluid density and momentum. In all the cases studied, the jet is found to be completely dissipated in approximately 30 jet diameters, thus giving rise to a uniform flow with a very high but constant turbulence field across the confinement.
Anatomic Double Bundle single tunnel Foreign Material Free ACL-Reconstruction – a technical note
Felmet, Gernot
2011-01-01
Summary The anterior cruciate ligament (ACL) consists of two bundles, the anteromedial (AM) and posterolateral bundle (PM). Double bundle reconstructions appear to give better rotational stability. The usual technique is to make two tunnels in the femur and two in the tibia. This is difficult and in small knees may not even be possible. We have developed a foreign material free press fit fixation for double bundle ACL reconstruction using a single femoral tunnel (R). This is based on the ALL PRESS FIT ACL reconstruction. It is suitable for the most common medium and, otherwise difficult, small sizes of knees. Method: Using diamond edged wet grinding hollow reamers, bone cylinders in different diameters are harvested from the implantation tunnels of the tibia and femur and used for the press fit fixation. Using the press fit technique the graft is first fixed in tibia. It is then similarly fixed under tension in the femoral side with the knee in 120 degree flexion. This is called Bottom To Top Fixation (BTT). On extending the knee the graft tension is self adapting. Depending on the size of the individual knee, the diameter of the femoral bone plug is varied from 8 to 13 mm to achieve an anatomic spread with a double bundle-like insertion. The tibia tunnel can be applied with two 7 or 8 mm diameter tunnels overlapping to a semi oval tunnel between 10 to 13 mm. Results: Since May 2003 we have carried out ACL-reconstructions with Hamstring grafts without foreign material using the ALL PRESS FIT technique. Initially, an 8 mm press fit fixation was used proximally with good results. Since April 2008, the range of diameters was increased up to 13 mm. The results of the Lachman tests have been good to excellent. Results of the Pivot shift test suggested more stability with femoral broader diameters of 9,5 to 13 mm. Conclusions: The foreign material free fixation of ham-string in the ALL PRESS FIT Bottom To Top Fixation is a successful method for ACL Reconstruction. The Diamond Instruments and tubed guiding devices are precise, reliable and easy to manage. On this basis a double bundle reconstruction is achieved using a single tunnel. A broad anatomic femoral insertion with autogenous bone plugs inserted near the cortex seems to improve rotational stability. PMID:23738263
Oversized 250 GHz Traveling Wave Tube with a Photonic Band-Gap Structure
NASA Astrophysics Data System (ADS)
Rosenzweig, Guy; Shapiro, Michael A.; Temkin, Richard J.
2017-10-01
The challenge in manufacturing traveling wave tubes (TWTs) at high frequencies is that the sizes of the structures scale with, and are much smaller than, the wavelength. We have designed and are building a 250 GHz TWT that uses an oversized structure to overcome fabrication and power handling issues that result from the small dimensions. Using a photonic band-gap (PBG) structure, we succeeded to design the TWT with a beam tunnel diameter of 0.72 mm. The circuit consists of metal plates with the beam tunnel drilled down their center. Twelve posts are protruding on one side of each plate in a triangular array and corresponding sockets are drilled on the other side. The posts of each plate are inserted into the sockets of an adjacent plate, forming a PBG lattice. The vacuum spacing between adjacent plates forms the `PBG cavity''. The full structure is a series of PBG coupled cavities, with microwave power coupling through the beam tunnel. The PBG lattice provides confinement of microwave power in each of the cavities and can be tuned to give the right amount of diffraction per cavity so that no sever is needed to suppress oscillations in the operating mode. CST PIC simulations predict over 38 dB gain with 67 W peak power, using a 30 kV, 310 mA electron beam, 0.6 mm in diameter. Research supported by the AFOSR Program on Plasma and Electro-Energetic Physics and by the NIH National Institute of Biomedical Imaging and Bioengineering.
Soft Polymers for Building up Small and Smallest Blood Supplying Systems by Stereolithography
Meyer, Wolfdietrich; Engelhardt, Sascha; Novosel, Esther; Elling, Burkhard; Wegener, Michael; Krüger, Hartmut
2012-01-01
Synthesis of a homologous series of photo-polymerizable α,ω-polytetrahydrofuranether-diacrylate (PTHF-DA) resins is described with characterization by NMR, GPC, DSC, soaking and rheometrical measurements. The curing speeds of the resins are determined under UV light exposure. Young’s modulus and tensile strength of fully cured resins show flexible to soft material attributes dependent on the molar mass of the used linear PTHF-diacrylates. Structuring the materials by stereo lithography (SL) and multiphoton polymerization (MPP) leads to tubes and bifurcated tube systems with a diameter smaller than 2 mm aimed at small to smallest supplying systems with capillary dimensions. WST-1 biocompatibility tests ofm polymer extracts show nontoxic characteristics of the adapted polymers after a washing process. Some polymers show shape memory effect (SME). PMID:24955530
Discharging Static Electricity From Inside A Glass Tube
NASA Technical Reports Server (NTRS)
Ellsbury, Walter L.
1994-01-01
Device that contains emitter of alpha particles discharges static electricity from inside wall of glass tube of volumetric-flow calibrator. Includes cylinder that has wall thickness of 1/16 in., diameter about 1/2 in. smaller than inside diameter of tube, and height that extends about 1/2 in. above piston that moves along tube and is part of calibrator.
NASA Astrophysics Data System (ADS)
Ahmadi Nadooshan, Afshin; Kalbasi, Rasool; Afrand, Masoud
2018-04-01
Perforated fins effects on the heat transfer rate of a circular tube are examined experimentally. An experimental system is set up through the wind tunnel and equipped with necessary measurement tools. Hot water passes through the finned tube and heat transfers to the fin-side air created using the wind tunnel with different velocities. Two fin sets of identical weight are installed on a circular tube with different outer diameters of 22 and 26 mm. The experiments are conducted at two different mass flow rates of the hot water and six Reynolds number of external air flow. Considering the four finned tubes and one no finned tube, a total of 60 tests are conducted. Results showed that with increasing the internal or external flow rates, the effect of larger cross-sectional area is greater. By opening holes on the fins, in addition to weight loss, the maximum heat transfer rate for perforated fins increases by 8.78% and 9.23% respectively for mass flow rates of 0.05 and 0.1 kg/s at low external Reynolds number. While, at high external Reynolds number, the holes reduces heat transfer by 8.4% and 10.6% for mass flow rates of 0.05 and 0.1 kg/s, respectively.
Analogue saturation limit of single and double 10 mm microchannel plate photomultiplier tubes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milnes, J. S., E-mail: james.milnes@photek.co.uk; Conneely, T. M.; Horsfield, C. J.
Photek are a well-established supplier of microchannel plate (MCP) photomultiplier tubes (PMTs) to the inertial confinement fusion community. The analogue signals produced at the major inertial confinement fusion facilities cover many orders of magnitude, therefore understanding the upper saturation limit of MCP-PMTs to large low rate signals takes on a high importance. Here we present a study of a single and a double MCP-PMT with 10 mm diameter active area. The saturation was studied for a range of optical pulse widths from 4 ns to 100 ns and at a range of electron gain values: 10{sup 3} to 10{sup 4}more » for the single and 10{sup 4} to 10{sup 6} for the double. We have shown that the saturation level of ∼1.2 nC depends only on the integrated charge of the pulse and is independent of pulse width and gain over this range, but that the level of charge available in deep saturation is proportional to the operating gain.« less
Visual analysis of flow boiling at different gravity levels in 4.0 mm tube
NASA Astrophysics Data System (ADS)
Valencia-Castillo, C. M.; Celata, G. P.; Saraceno, L.; Zummo, G.
2014-11-01
The aim of the present paper is to describe the results of flow boiling heat transfer at low gravity and compare them with those obtained at earth gravity, evaluating possible differences. The experimental campaigns at low gravity have been performed during the parabolic flight campaign of October-November 2013. The paper will show the analysis of differences between the heat transfer coefficients and vapour bubble parameters at normal and at zero gravity. The results of 4.0 mm tube are presented and discussed. With respect to terrestrial gravity, heat transfer is systematically lower at microgravity in the range of the experimental conditions. Heat transfer differences for the two gravity conditions are related to the different bubble size in each of them. The size of a bubble in flow boiling is affected by the gravity level, being larger at low gravity, unless inertial forces are largely predominant over buoyancy and other forces acting on the bubble itself when detaching from a heated wall. Vapour bubble parameters (bubble diameter, bubble length, width, and nose velocity) have been measured.
Sap volume flow as influenced by tubing diameter and slope percent
H. Clay Smith
1971-01-01
The amount of sugar maple sap that can move through plastic tubing is controlled by several factors. The most important are tubing diameter and slope percent. Estimates are given of the number of tapholes that can be used with combinations of these variables.
Risk factors for proximal migration of biliary tube stents.
Kawaguchi, Yoshiaki; Ogawa, Masami; Kawashima, Yohei; Mizukami, Hajime; Maruno, Atsuko; Ito, Hiroyuki; Mine, Tetsuya
2014-02-07
To analyze the risk factors for biliary stent migration in patients with benign and malignant strictures. Endoscopic stent placement was performed in 396 patients with bile duct stenosis, at our institution, between June 2003 and March 2009. The indications for bile duct stent implantation included common bile duct stone in 190 patients, malignant lesions in 112, chronic pancreatitis in 62, autoimmune pancreatitis in 14, trauma in eight, surgical complications in six, and primary sclerosing cholangitis (PSC) in four. We retrospectively examined the frequency of stent migration, and analyzed the patient factors (disease, whether endoscopic sphincterotomy was performed, location of bile duct stenosis and diameter of the bile duct) and stent characteristics (duration of stent placement, stent type, diameter and length). Moreover, we investigated retrieval methods for migrated stents and their associated success rates. The frequency of tube stent migration in the total patient population was 3.5%. The cases in which tube stent migration occurred included those with common bile duct stones (3/190; 1.6%), malignant lesions (2/112; 1.8%), chronic pancreatitis (4/62; 6.5%), autoimmune pancreatitis (2/14; 14.3%), trauma (1/8; 12.5%), surgical complications (2/6; 33.3%), and PSC (0/4; 0%). The potential risk factors for migration included bile duct stenosis secondary to benign disease such as chronic pancreatitis and autoimmune pancreatitis (P = 0.030); stenosis of the lower bile duct (P = 0.031); bile duct diameter > 10 mm (P = 0.023); duration of stent placement > 1 mo (P = 0.007); use of straight-type stents (P < 0.001); and 10-Fr sized stents (P < 0.001). Retrieval of the migrated stents was successful in all cases. The grasping technique, using a basket or snare, was effective for pig-tailed or thin and straight stents, whereas the guidewire cannulation technique was effective for thick and straight stents. Migration of tube stents within the bile duct is rare but possible, and it is important to determine the risk factors involved in stent migration.
Rechargeable Biofilm-Controlling Tubing Materials for Use in Dental Unit Water Lines
Luo, Jie; Porteous, Nuala; Sun, Yuyu
2011-01-01
A simple and practical surface grafting approach was developed to introduce rechargeable N-halamine-based antimicrobial functionality onto the inner surfaces of continuous small-bore polyurethane (PU) dental unit waterline (DUWL) tubing. In this approach, tetrahydrofuran (THF) solution of a free-radical initiator, dicumyl peroxide (DCP), flowed through the PU tubing (inner diameter of 1/16 inch, or 1.6 mm) to diffuse DCP into the tube’s inner walls, which was used as initiator in the subsequent grafting polymerization of methacrylamide (MAA) onto the tubing. Upon chlorine bleach treatment, the amide groups of the grafted MAA side chains were transformed into acyclic N-halamines. The reactions were confirmed with attenuated total reflectance infrared (ATR) spectra and iodometric titration. The mechanical properties of the tubing were not significantly affected by the grafting reactions. The biofilm-controlling function of the new N-halamine-based PU tubing was evaluated with Pseudomonas aeruginosa (P. aeruginosa), one of the most isolated water bacteria from DUWLs, in a continuous bacterial flow model. Bacteria culturing and SEM studies showed that the inner surfaces of the new N-halamine-based PU tubing completely prevented bacterial biofilm formation for at least three to four weeks. After that, bacteria began to colonize the tubing surface. However, the lost function was fully regenerated by exposing the tubing inner surfaces to diluted chlorine bleach. The recharging process could be repeated periodically to further extend the biofilm-controlling duration for long-term applications. PMID:21721534
The axial crushes behaviour on foam-filled round Jute/Polyester composite tubes
NASA Astrophysics Data System (ADS)
Othman, A.; Ismail, A. E.
2018-04-01
The present paper investigates the effect of axial loading compression on jute fibre reinforced polyester composite round tubes. The specimen of composite tube was fabricated by hand lay-up method of 120 mm length with fix 50.8 mm inner diameter to determine the behaviour of energy absorption on number of layers of 450 angle fibre and internally reinforced with and without foam filler material. The foam filler material used in this studies were polyurethane (PU) and polystyrene (PE) with average of 40 and 45 kg/m3 densities on the axial crushing load against displacement relations and on the failure modes. The number of layers of on this study were two; three and four were selected to calculate the crush force efficiency (CFE) and the specific energy absorption (SEA) of the composite tubes. Result indicated that the four layers’ jute/polyester show significant value in term of crushing load compared to 2 and 3 layers higher 60% for 2 layer and 3% compared to 3 layers. It has been found that the specific energy absorption of the jute/polyester tubes with polystyrene foam-filled is found higher respectively 10% to 12% than empty and polyurethane (PU) foam tubes. The increase in the number of layers from two to four increases the mean axial load from 1.01 KN to 3.60 KN for empty jute/polyester and from 2.11 KN to 4.26 KN for the polyurethane (PU) foam-filled jute/polyester tubes as well as for 3.60 KN to 5.58 KN for the polystyrene (PE) foam-filled jute/polyester. The author’s found that the failure of mechanism influence the characteristic of curve load against displacement obtained and conclude that an increasing number of layers and introduce filler material enhance the capability of specific absorbed energy.
Surface treatment of a titanium implant using low temperature atmospheric pressure plasmas
NASA Astrophysics Data System (ADS)
Lee, Hyun-Young; Tang, Tianyu; Ok, Jung-Woo; Kim, Dong-Hyun; Lee, Ho-Jun; Lee, Hae June
2015-09-01
During the last two decades, atmospheric pressure plasmas(APP) are widely used in diverse fields of biomedical applications, reduction of pollutants, and surface treatment of materials. Applications of APP to titanium surface of dental implants is steadily increasing as it renders surfaces wettability and modifies the oxide layer of titanium that hinders the interaction with cells and proteins. In this study, we have treated the titanium surfaces of screw-shaped implant samples using a plasma jet which is composed of a ceramic coaxial tube of dielectrics, a stainless steel inner electrode, and a coper tube outer electrode. The plasma ignition occurred with Ar gas flow between two coaxial metal electrodes and a sinusoidal bias voltage of 3 kV with a frequency of 20 kHz. Titanium materials used in this study are screw-shaped implants of which diameter and length are 5 mm and 13 mm, respectively. Samples were mounted at a distance of 5 mm below the plasma source, and the plasma treatment time was set to 3 min. The wettability of titanium surface was measured by the moving speed of water on its surface, which is enhanced by plasma treatment. The surface roughness was also measured by atomic force microscopy. The optimal condition for wettability change is discussed.
Ménard, Lucie; Turgeon, Christine; Trudeau-Fisette, Paméla; Bellavance-Courtemanche, Marie
2016-01-01
The impact of congenital visual deprivation on speech production in adults was examined in an ultrasound study of compensation strategies for lip-tube perturbation. Acoustic and articulatory analyses of the rounded vowel /u/ produced by 12 congenitally blind adult French speakers and 11 sighted adult French speakers were conducted under two conditions: normal and perturbed (with a 25-mm diameter tube inserted between the lips). Vowels were produced with auditory feedback and without auditory feedback (masked noise) to evaluate the extent to which both groups relied on this type of feedback to control speech movements. The acoustic analyses revealed that all participants mainly altered F2 and F0 and, to a lesser extent, F1 in the perturbed condition - only when auditory feedback was available. There were group differences in the articulatory strategies recruited to compensate; while all speakers moved their tongues more backward in the perturbed condition, blind speakers modified tongue-shape parameters to a greater extent than sighted speakers.
Condensation of Forced Convection Two-Phase Flow in a Miniature Tube
NASA Technical Reports Server (NTRS)
Begg, E.; Faghri, A.; Krustalev, D.
1999-01-01
A physical/mathematical model of annular film condensation at the inlet of a miniature tube has been developed. In the model, the liquid flow is coupled with the vapor flow along the liquid-vapor interface through the interfacial temperature, heat flux, shear stress, and pressure jump conditions due to surface tension effects. The model predicts the shape of the liquid-vapor interface along the condenser and leads to the conclusion that there is complete condensation at a certain distance from the condenser inlet. The numerical results show that complete condensation of the incoming vapor is possible at comparatively low heat loads and that this is a special case of a more general condensation regime with two-phase bubbly flow downstream of the initial annular film condensation region. Observations from the flow visualization experiment confirm the existence and qualitative features of annular film condensation leading to the complete condensation phenomenon in a small diameter (3.25 mm) circular tube condenser.
Behavior of the lean methane-air flame at zero-gravity
NASA Technical Reports Server (NTRS)
Noe, K. A.; Strehlow, R. A.
1985-01-01
A special rig was designed and constructed to be compatible with the NASA Lewis Research Center Airborne Research Laboratory to allow the study of the effect of gravity on the behavior of lean limit in a standard 50.4 mm (2 in.) internal diameter tube when the mixtures are ignited at the open end and propagate towards the closed end of the tube. The lean limit at zero gravity was found to be 5.10% methane and the flame was found to extenguish in a manner previously observed for downward propagating flames at one g. It was observed that g-jitter could be maintained at less than + or 0.04 g on most zero g trajectories. All of propagating lean limit flames were found to be sporadically cellularly unstable at zero g. There was no observable correlation between the occurrence of g-jitter and the lean limit, average propagation speed of the flame through the tube or the occurrence of cellular instability.
NASA Technical Reports Server (NTRS)
Keshock, E. G.
1975-01-01
Basic equations of momentum and energy are presented and discussed with respect to heat transfer and pressure drop for forced flow condensation in horizontal tubes under 1-g and 0-g conditions. Some experimental results are presented for condensing refrigerant-12 in a system of three parallel-connected quartz tubes (3-mm inside diameter, G = 1.037 to 3.456 x 105 lbm/hr-sq. ft). From high speed photographs, measurements were obtained of film thickness, phase velocities, disturbance wavelengths, and flow regimes and their transitions. Based upon these measurements various dimensionless force ratios (flow and instability parameters) were calculated. Under 0-g conditions a uniformly thick redistribution of liquid condensate about the tube walls was found to result in a lowered heat transfer coefficient as compared with 1-g conditions, based upon fundamental heat transfer theory. A model is proposed that takes into account the difference in heat transfer due to condensate distribution under 1-g and 0-g conditions.
Development and performance evaluation of an experimental fine pitch detector multislice CT scanner.
Imai, Yasuhiro; Nukui, Masatake; Ishihara, Yotaro; Fujishige, Takashi; Ogata, Kentaro; Moritake, Masahiro; Kurochi, Haruo; Ogata, Tsuyoshi; Yahata, Mitsuru; Tang, Xiangyang
2009-04-01
The authors have developed an experimental fine pitch detector multislice CT scanner with an ultrasmall focal spot x-ray tube and a high-density matrix detector through current CT technology. The latitudinal size of the x-ray tube focal spot was 0.4 mm. The detector dimension was 1824 channels (azimuthal direction) x 32 rows (longitudinal direction) at row width of 0.3125 mm, in which a thinner reflected separator surrounds each detector cell coupled with a large active area photodiode. They were mounted on a commercial 64-slice CT scanner gantry while the scan field of view (50 cm) and gantry rotation speed (0.35 s) can be maintained. The experimental CT scanner demonstrated the spatial resolution of 0.21-0.22 mm (23.8-22.7 lp/cm) with the acrylic slit phantom and in-plane 50%-MTF 9.0 lp/cm and 10%-MTF 22.0 lp/cm. In the longitudinal direction, it demonstrated the spatial resolution of 0.24 mm with the high-resolution insert of the CATPHAN phantom and 0.34 mm as the full width at half maximum of the slice sensitivity profile. In low-contrast detectability, 3 mm at 0.3% was visualized at the CTDI(vol) of 47.2 mGy. Two types of 2.75 mm diameter vessel phantoms with in-stent stenosis at 25%, 50%, and 75% stair steps were scanned, and the reconstructed images can clearly resolve the stenosis at each case. The experimental CT scanner provides high-resolution imaging while maintaining low-contrast detectability, demonstrating the potentiality for clinical applications demanding high spatial resolution, such as imaging of inner ear, lung, and bone, or low-contrast detectability, such as imaging of coronary artery.
NASA Technical Reports Server (NTRS)
Bauer, Christopher
1993-01-01
Stirling engine heat exchangers are shell-and-tube type with oscillatory flow (zero-mean velocity) for the inner fluid. This heat transfer process involves laminar-transition turbulent flow motions under oscillatory flow conditions. A low Reynolds number kappa-epsilon model, (Lam-Bremhorst form), was utilized in the present study to simulate fluid flow and heat transfer in a circular tube. An empirical transition model was used to activate the low Reynolds number k-e model at the appropriate time within the cycle for a given axial location within the tube. The computational results were compared with experimental flow and heat transfer data for: (1) velocity profiles, (2) kinetic energy of turbulence, (3) skin friction factor, (4) temperature profiles, and (5) wall heat flux. The experimental data were obtained for flow in a tube (38 mm diameter and 60 diameter long), with the maximum Reynolds number based on velocity being Re(sub max) = 11840, a dimensionless frequency (Valensi number) of Va = 80.2, at three axial locations X/D = 16, 30 and 44. The agreement between the computations and the experiment is excellent in the laminar portion of the cycle and good in the turbulent portion. Moreover, the location of transition was predicted accurately. The Low Reynolds Number kappa-epsilon model, together with an empirical transition model, is proposed herein to generate the wall heat flux values at different operating parameters than the experimental conditions. Those computational data can be used for testing the much simpler and less accurate one dimensional models utilized in 1-D Stirling Engine design codes.
Effect of tendon tensioning: an in vitro study in porcine extensor tendons.
Figueroa, David; Calvo, Rafael; Vaisman, Alex; Meleán, Patricio; Figueroa, Francisco
2010-06-01
Graft tensioning is a controversial issue in anterior cruciate ligament reconstruction (ACLR) that has not achieved consensus between peers. The purpose of this study is to determine if after tensioning tendon length and resistance to maximal load changes. We performed an in vitro study with 50 porcine extensors tendons. The first group (P=25) was tensioned with 80 N (19.97 lb) for 10 min, using an ACL graft preparation board. The second group (C=25) was used as control and was not tensioned. The average initial (groups P and C) and post tensioning tendon length (group C) were measured; the average initial and post tensioning tendon diameter were measured as well. All samples were fixated in a tube-clamp system connected to a tension sensor. The samples were stressed with continuous and progressive tension until ultimate failure at maximum load (UFML) occurs. The initial mean length was: P before tensioning=13.4 mm+/-1.4 mm (range 10.5-16.5); P after tensioning=13.8 mm+/-1.4 mm (range 11.5-16.5); C=13 mm+/-1.35 mm (p=0.005). The mean diameter was: P=5.6 mm (4.5-6); C=5.5 mm (range 4.5-6) (p>0.05). The UFML was: P=189.7 N (114-336); C=229.9 N (143-365) (p=0.029). Tendon tensioning with 80 N for 10 min produced 3% average elongation. These could be beneficial in ACLR since tendon tensioning decreases elongation of the graft after fixation. Regardless, tendon tensioning is not innocuous since it diminishes their resistance when continuously stressed until complete failure occurs.
Optical instrument for measurement of vaginal coating thickness by drug delivery formulations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Henderson, Marcus H.; Peters, Jennifer J.; Walmer, David K.
2005-03-01
An optical device has been developed for imaging the human vaginal epithelial surfaces, and quantitatively measuring distributions of coating thickness of drug delivery formulations - such as gels - applied for prophylaxis, contraception or therapy. The device consists of a rigid endoscope contained within a 27-mm-diam hollow, polished-transparent polycarbonate tube (150 mm long) with a hemispherical cap. Illumination is from a xenon arc. The device is inserted into, and remains stationary within the vagina. A custom gearing mechanism moves the endoscope relative to the tube, so that it views epithelial surfaces immediately apposing its outer surface (i.e., 150 mm longmore » by 360 deg. azimuthal angle). Thus, with the tube fixed relative to the vagina, the endoscope sites local regions at distinct and measurable locations that span the vaginal epithelium. The returning light path is split between a video camera and photomultiplier. Excitation and emission filters in the light path enable measurement of fluorescence of the sited region. Thus, the instrument captures video images simultaneously with photometric measurement of fluorescence of each video field [{approx}10 mm diameter; formulations are labeled with 0.1% w/w United States Pharmacoepia (USP) injectable sodium fluorescein]. Position, time and fluorescence measurements are continuously displayed (on video) and recorded (to a computer database). The photomultiplier output is digitized to quantify fluorescence of the endoscope field of view. Quantification of the thickness of formulation coating of a surface sited by the device is achieved due to the linear relationship between thickness and fluorescence intensity for biologically relevant thin layers (of the order of 0.5 mm). Summary measures of coating have been developed, focusing upon extent, location and uniformity. The device has begun to be applied in human studies of model formulations for prophylaxis against infection with HIV and other sexually transmitted pathogens.« less
NASA Astrophysics Data System (ADS)
Sosa, C. S.; Thompson, S. J.; Chichester, D. L.; Clarke, S. D.; Di Fulvio, A.; Pozzi, S. A.
2018-08-01
An increase in light-collection efficiency (LCE) improves the energy resolution of scintillator-based detection systems. An improvement in energy resolution can benefit detector performance, for example by lowering the measurement threshold and achieving greater accuracy in light-output calibration. This work shows that LCE can be increased by modifying the scintillator shape to reduce optical-photon reflections, thereby decreasing transmission and absorption likelihood at the reflector boundary. The energy resolution of four organic scintillators (EJ200) were compared: two cones and two right-circular cylinders, all with equal base diameter and height (50 mm). The sides of each shape had two surface conditions: one was polished and the other was ground. Each scintillator was coupled to the center of four photomultiplier tube (PMT) configurations of different diameters. The photocathode response of all PMTs was assessed as a function of position using a small cube (5 mm height) of EJ200. The worst configuration, a highly polished conical scintillator mated to a PMT of equal base diameter, produced a smeared energy spectrum. The cause of spectrum smearing is explored in detail. Results demonstrate that a ground cone had the greatest improvement in energy resolution over a ground cylinder by approximately 16.2% at 478 keVee, when using the largest diameter (127 mm) PMT. This result is attributed to the greater LCE of the cone, its ground surface, and the uniform photocathode response near center of the largest PMT. Optical-photon transport simulations in Geant4 of the cone and cylinder assuming a diffuse reflector and a uniform photocathode were compared to the best experimental configuration and agreed well. If a detector application requires excellent energy resolution above all other considerations, a ground cone on a large PMT is recommended over a cylinder.
Rapid surface colony counts determination with three new miniaturised techniques.
Malik, K A
1977-01-01
Three different miniaturised methods for the rapid surface viable counting are described. The methods were tried in parallel to seven different existing methods (Table 1) for viable counts and were found to be easier, quicker and insome cases more accurate. The techniques require about 10% of the material and time needed for conventional spread-plates method and the results were in no way inferior to that (Table 1 and 2). Mini agar discs were cut aseptically with an especially designed stainless steel agar disc cutter (25 mm internal and 28 mm external diameter, Fig. 1b) or with a test tube of similar diameter. The area of the resulted mini-agar-disc of 25 mm diameter was kept such (about 1/10th of the normal plate) that the ratio of the colony-bearing area to the inoculm remained the same as on big plates in spread-plate-method (Table 2). In normal Petri dishes (about 90 mm diameter) up to seven mini agar discs were possible to cut. Each small agar disc was seperated from the other mini-disc by a distance of at least 6 mm (Fig. 1a). The empty place around the disc was still enlarged during over drying of the plates and during incubation. This created complete isolation from the neighbouring disc. For micro-determination of surface viable counts 10 micronl from each dilution was delivered on a well-dired mini-disc with a piston micropipette. The inoculm was immediately spread on the whole mini-disc with a specially designed flame sterilizable platinum-Mini-spreader (Fig. 2a). No spinning of the plate was needed. Alternatively the dropping pipette and spreader was replaced by a calibrated platinum wire Loop-spreader (Fig. 2b). A loop of 3 mm internal diameter made from a platinum-iridium wire of 0.75 mm thickness proved most useful and carried a drop of 10 micronl. Differences especially in surface tension of various diluting fluids did not influence to drop of this size and no recalibration was needed for water and nutrient broth. The loop was further shaped to Loop-spreader form. From each bacterial suspension 10 micronl were carried and spread on each mini-disc. The method is useful for pathogenic organisms as the loop can readily be flame sterilized. For routine purposes where only approximate numbers of bacteria need to be known a still rapid semiquantitative method was deviced making use of a calibrated stainless steel Stamping-disc (Fig. 2c). A disc of 25mm diameter and 1 mm thickness delivered approximateyl 10 microlitres of supensions and was found to be most useful to stamp seven dilutions on a single plate. In collections and bacteriology laboratories where by conventional methods large number of plates are to be plated and counted the presented techniques could prove most convenient, rapid and economical.
Root and shoot responses of Taxodium distichum seedlings subjected to saline flooding
Krauss, K.W.; Chambers, J.L.; Allen, J.A.; Luse, B.P.; DeBosier, A.S.
1999-01-01
Variation among progeny of five half-sib family collections of baldcypress (Taxodium distichum) from three freshwater and two brackish-water seed sources subjected to saline flooding was evaluated Mini-rhizotrons (slant tubes) were used to monitor root elongation for a period of 99 days. Salinity level produced significant effects across all baldcypress half-sib families, with root elongation averaging 1594.0, 956.8, and 382.1 mm, respectively, for the 0, 4, and 6 g l-1 treatments. Combined mean root elongation for families from brackish-water seed sources was greater (1236.7 mm) than for families from freshwater seed sources (794.6 mm). Considerable variation occurred at the highest salinity treatment, however, with one freshwater family maintaining more than 28% more root growth than the average of the two brackish-water collections. Hence, results indicate that short-term evaluation of root elongation at these salinity concentrations may not be a reliable method for salt tolerance screening of baldcypress. Species-level effects for height and diameter, which were measured at day 62, were significant for both parameters. Height increment in the control (7.4 cm), for example, was approximately five times greater than height increment in the 6 g l-1 salinity treatment (1.5 cm). Family-level variation was significant only for diameter, which had an incremental range of 0.2 to 1.5 mm across all salinity levels.
Characterization of a Laser-Generated Perturbation in High-Speed Flow for Receptivity Studies
2014-01-01
to trip the boundary layer. Figure 1. Schematic of the Boeing/AFOSR Mach-6 Quiet Tunnel (BAM6QT) The BAM6QT is a Ludwieg tube with a double- burst ...reduced to a 4-mm beam diameter by an aperture. Although the PIV-400 is a double- pulse laser, only the first pulse is used to generate perturbations in the...also both seeded, and pulse at 10 Hz, with a pulse width of about 7 ns. 2. Forming Optics The laser-generated perturbation is created by focusing a
Irradiation creep of dispersion strengthened copper alloy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pokrovsky, A.S.; Barabash, V.R.; Fabritsiev, S.A.
1997-04-01
Dispersion strengthened copper alloys are under consideration as reference materials for the ITER plasma facing components. Irradiation creep is one of the parameters which must be assessed because of its importance for the lifetime prediction of these components. In this study the irradiation creep of a dispersion strengthened copper (DS) alloy has been investigated. The alloy selected for evaluation, MAGT-0.2, which contains 0.2 wt.% Al{sub 2}O{sub 3}, is very similar to the GlidCop{trademark} alloy referred to as Al20. Irradiation creep was investigated using HE pressurized tubes. The tubes were machined from rod stock, then stainless steel caps were brazed ontomore » the end of each tube. The creep specimens were pressurized by use of ultra-pure He and the stainless steel caps subsequently sealed by laser welding. These specimens were irradiated in reactor water in the core position of the SM-2 reactors to a fluence level of 4.5-7.1 x 10{sup 21} n/cm{sup 2} (E>0.1 MeV), which corresponds to {approx}3-5 dpa. The irradiation temperature ranged from 60-90{degrees}C, which yielded calculated hoop stresses from 39-117 MPa. A mechanical micrometer system was used to measure the outer diameter of the specimens before and after irradiation, with an accuracy of {+-}0.001 mm. The irradiation creep was calculated based on the change in the diameter. Comparison of pre- and post-irradiation diameter measurements indicates that irradiation induced creep is indeed observed in this alloy at low temperatures, with a creep rate as high as {approx}2 x 10{sup {minus}9}s{sup {minus}1}. These results are compared with available data for irradiation creep for stainless steels, pure copper, and for thermal creep of copper alloys.« less
Core-free rolled actuators for Braille displays using P(VDF-TrFE-CFE)
NASA Astrophysics Data System (ADS)
Levard, Thomas; Diglio, Paul J.; Lu, Sheng-Guo; Rahn, Christopher D.; Zhang, Q. M.
2012-01-01
Refreshable Braille displays require many small diameter actuators to move the pins. The electrostrictive P(VDF-TrFE-CFE) terpolymer can provide the high strain and actuation force under modest electric fields that are required for this application. In this paper, we develop core-free tubular actuators and integrate them into a 3 × 2 Braille cell. The terpolymer films are solution cast, stretched to 6 μm thick, electroded, laminated into a bilayer, rolled into a 2 mm diameter tube, bonded, and provided with top and bottom contacts. Experimental testing of 17 actuators demonstrates significant strains (up to 4%) and blocking forces (1 N) at moderate electric fields (100 MV m-1). A novel Braille cell is designed and fabricated using six of these actuators.
Low-Current, Xenon Orificed Hollow Cathode Performance for In-Space Applications
NASA Technical Reports Server (NTRS)
Domonkos, Matthew T.; Patterson, Michael J.; Gallimore, Alec D.
2002-01-01
An experimental investigation of the operating characteristics of 3.2-mm diameter orificed hollow cathodes was conducted to examine low current and low flow rate operation. Cathode power was minimized with an orifice aspect ratio of approximately one and the use of an enclosed keeper. Cathode flow rate requirements were proportional to orifice diameter and the inverse of the orifice length. The minimum power consumption in diode mode was 10-W, and the minimum mass flow rate required for spot-mode emission was approximately 0.08-mg/s. Cathode temperature profiles were obtained using an imaging radiometer and conduction was found to be the dominant heat transfer mechanism from the cathode tube. Orifice plate temperatures were found to be weakly dependent upon the flow rate and strongly dependent upon the current.
Design criteria for developing low-resource magnetic bead assays using surface tension valves
Adams, Nicholas M.; Creecy, Amy E.; Majors, Catherine E.; Wariso, Bathsheba A.; Short, Philip A.; Wright, David W.; Haselton, Frederick R.
2013-01-01
Many assays for biological sample processing and diagnostics are not suitable for use in settings that lack laboratory resources. We have recently described a simple, self-contained format based on magnetic beads for extracting infectious disease biomarkers from complex biological samples, which significantly reduces the time, expertise, and infrastructure required. This self-contained format has the potential to facilitate the application of other laboratory-based sample processing assays in low-resource settings. The technology is enabled by immiscible fluid barriers, or surface tension valves, which stably separate adjacent processing solutions within millimeter-diameter tubing and simultaneously permit the transit of magnetic beads across the interfaces. In this report, we identify the physical parameters of the materials that maximize fluid stability and bead transport and minimize solution carryover. We found that fluid stability is maximized with ≤0.8 mm i.d. tubing, valve fluids of similar density to the adjacent solutions, and tubing with ≤20 dyn/cm surface energy. Maximizing bead transport was achieved using ≥2.4 mm i.d. tubing, mineral oil valve fluid, and a mass of 1-3 mg beads. The amount of solution carryover across a surface tension valve was minimized using ≤0.2 mg of beads, tubing with ≤20 dyn/cm surface energy, and air separators. The most favorable parameter space for valve stability and bead transport was identified by combining our experimental results into a single plot using two dimensionless numbers. A strategy is presented for developing additional self-contained assays based on magnetic beads and surface tension valves for low-resource diagnostic applications. PMID:24403996
Enlargement of halloysite clay nanotube lumen by selective etching of aluminum oxide.
Abdullayev, Elshad; Joshi, Anupam; Wei, Wenbo; Zhao, Yafei; Lvov, Yuri
2012-08-28
Halloysite clay tubes have 50 nm diameter and chemically different inner and outer walls (inner surface of aluminum oxide and outer surface of silica). Due to this different chemistry, the selective etching of alumina from inside the tube was realized, while preserving their external diameter (lumen diameter changed from 15 to 25 nm). This increases 2-3 times the tube lumen capacity for loading and further sustained release of active chemical agents such as metals, corrosion inhibitors, and drugs. In particular, halloysite loading efficiency for the benzotriazole increased 4 times by selective etching of 60% alumina within the tubes' lumens. Specific surface area of the tubes increased over 6 times, from 40 to 250 m(2)/g, upon acid treatment.
NASA Astrophysics Data System (ADS)
Hwang, Da Young; Suh, Dong Hack
2014-05-01
Unlike nanoscrolls of 2D graphene, those of 2D h-BN have not been demonstrated, except for only a few experimental reports. Nanoscrolls of h-BN with high yields and reproducibility are first synthesized by a simple solution process. Inner-tube diameters of BNSs including LCAs, N-(2-aminoethyl)-3α-hydroxy-5β-cholan-24-amide, a bile acid derivative and self-assembling material, can be controlled by adjusting the diameter of the LCA fiber which is grown by self-assembly. TEM and SEM images show that BNSs have a tube-like morphology and the inner-tube diameter of BNSs can be controlled in the range from 20 to 60 nm for a smaller diameter, up to 300 nm for a larger diameter by LCA fiber growth inside the BNSs. Finally, open cylindrical BNSs with hollow cores were obtained by dissolving LCAs inside BNSs.Unlike nanoscrolls of 2D graphene, those of 2D h-BN have not been demonstrated, except for only a few experimental reports. Nanoscrolls of h-BN with high yields and reproducibility are first synthesized by a simple solution process. Inner-tube diameters of BNSs including LCAs, N-(2-aminoethyl)-3α-hydroxy-5β-cholan-24-amide, a bile acid derivative and self-assembling material, can be controlled by adjusting the diameter of the LCA fiber which is grown by self-assembly. TEM and SEM images show that BNSs have a tube-like morphology and the inner-tube diameter of BNSs can be controlled in the range from 20 to 60 nm for a smaller diameter, up to 300 nm for a larger diameter by LCA fiber growth inside the BNSs. Finally, open cylindrical BNSs with hollow cores were obtained by dissolving LCAs inside BNSs. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr00897a
Characteristics of an axisymmetric sudden expansion flow
NASA Technical Reports Server (NTRS)
Stevenson, W. H.; Thompson, H. D.
1985-01-01
A two-color, two component Laser Doppler Velocimeter (LDV) system operating in forward scatter has been developed in order to make simultaneous measurements of the axial and radial velocity components in an axisymmetric sudden expansion flow with and without combustion. The LDV system includes Bragg cell modulators in the four beam paths to allow a net frequency shift of 5MHz in both the green and blue beams. This permits an unambiguous measurement of negative velocities and also eliminates incomplete signal bias. The green beam probe volume has a waist diameter of 0.200 mm and is approximately 2mm long. The blue beam has a probe volume waist of 0.250 mm and is approximately 1 mm long. The scattered light from the probe volume is separated so that approximately 80% of each color passes to its respective photomultiplier tube by using a dichroic filter. Narrow bandpass filters are used to further filter unwanted signals before they are detected. A schematic diagram of the LDV system is shown.
1990-01-01
Uncuffed Endotracheal Tube Size, the Diameter of the Distal Digit of the Little Finger and the Penlington Formula 12. PERSONAL AUTHOR(S) Roy H. Fukuoka 13a...BETWEEN ACTUAL UNCUFFED ENDOTRACHEAL TUBE SIZE, THE DIAMETER OF THE DISTAL DIGIT OF THE LITTLE FINGER AND THE PENLINGTON FORMULA By Roy H. Fukuoka May... PENLINGTON FORMULA A THESIS PROPOSAL Presented to the Department of Nursing California State University, Long Beach In Partial Fulfillment of the
NASA Technical Reports Server (NTRS)
Pellett, G. L.; Northam, G. Burton; Wilson, L. G.
1991-01-01
Five coaxial tubular opposed jet burners (OJBs) with tube diameter D(T) of 1.8-10 mm and 5 mm conical nozzles were used to form dish-shaped counterflow diffusion flames centered by opposing laminar jets of nitrogen and hydrocarbon-diluted H2 versus air in an argon-purged chamber at 1 atm. Area-averaged air jet velocities at blowoff of the central flame, U(air), characterized extinction of the airside flame as functions of input H2 concentration on the fuelside. A master plot of extensive U(air) data at blowoff versus D(T) shows that U(air) varies linearly with D(T). This and other data sets are used to find that nozzle OJB results for U(air)/diameter average 4.24 + or - 0.28 times larger than tubular OJB results for the same fuel compositions. Critical radial velocity gradients consistent with one-dimensional stagnation point boundary theory and with plug flow inputs are estimated. The results compare favorably with published numerical results based only on potential flow.
Experimental and analytical studies in fluids
NASA Technical Reports Server (NTRS)
Goglia, Gene L.; Ibrahim, Adel
1984-01-01
The first objective was to analyze and design a true airspeed sensor which will replace the conventional pitot-static pressure transducer for small commercial aircraft. The second objective was to obtain a numerical solution and predict the frequency response which is generated by the vortex whistle at a certain airspeed. It was concluded flow rate measurements indicate that the vortex tube sound frequency is linearly proportional to the frequency response. The vortex tube whistle frequency is dependent upon geometrical parameters to such an extent that: an increase in vortex tube length produces a decrease in frequency response and that an increase in the exhaust nozzle length produces an increase in the frequency precession. An increase in the vortex tube diameter produces a decrease in frequency precession. An increase in swirler diameter produces a decrease in frequency. An increase in the location distance of the microphone pickup signal point from the inside edge of the exit nozzle produces an increase in frequency response. The experimental results indicate that those parameters most significantly effecting frequency are in descending order of importance microphone location, vortex tube diameter, exit nozzle length, vortex tube length, and swirler diameter.
Quantification of pulmonary vessel diameter in low-dose CT images
NASA Astrophysics Data System (ADS)
Rudyanto, Rina D.; Ortiz de Solórzano, Carlos; Muñoz-Barrutia, Arrate
2015-03-01
Accurate quantification of vessel diameter in low-dose Computer Tomography (CT) images is important to study pulmonary diseases, in particular for the diagnosis of vascular diseases and the characterization of morphological vascular remodeling in Chronic Obstructive Pulmonary Disease (COPD). In this study, we objectively compare several vessel diameter estimation methods using a physical phantom. Five solid tubes of differing diameters (from 0.898 to 3.980 mm) were embedded in foam, simulating vessels in the lungs. To measure the diameters, we first extracted the vessels using either of two approaches: vessel enhancement using multi-scale Hessian matrix computation, or explicitly segmenting them using intensity threshold. We implemented six methods to quantify the diameter: three estimating diameter as a function of scale used to calculate the Hessian matrix; two calculating equivalent diameter from the crosssection area obtained by thresholding the intensity and vesselness response, respectively; and finally, estimating the diameter of the object using the Full Width Half Maximum (FWHM). We find that the accuracy of frequently used methods estimating vessel diameter from the multi-scale vesselness filter depends on the range and the number of scales used. Moreover, these methods still yield a significant error margin on the challenging estimation of the smallest diameter (on the order or below the size of the CT point spread function). Obviously, the performance of the thresholding-based methods depends on the value of the threshold. Finally, we observe that a simple adaptive thresholding approach can achieve a robust and accurate estimation of the smallest vessels diameter.
Ito, Yoichiro; Ma, Xiaofeng; Clary, Robert
2016-01-01
A simple tool is introduced which can modify the shape of tubing to enhance the partition efficiency in high-speed countercurrent chromatography. It consists of a pair of interlocking identical gears, each coaxially holding a pressing wheel to intermittently compress plastic tubing in 0 – 10 mm length at every 1 cm interval. The performance of the processed tubing is examined in protein separation with 1.6 mm ID PTFE tubing intermittently pressed in 3 mm and 10 mm width both at 10 mm intervals at various flow rates and revolution speeds. A series of experiments was performed with a polymer phase system composed of polyethylene glycol and dibasic potassium phosphate each at 12.5% (w/w) in deionized water using three protein samples. Overall results clearly demonstrate that the compressed tubing can yield substantially higher peak resolution than the non-processed tubing. The simple tubing modifier is very useful for separation of proteins with high-speed countercurrent chromatography. PMID:27818942
Ito, Yoichiro; Ma, Xiaofeng; Clary, Robert
2016-01-01
A simple tool is introduced which can modify the shape of tubing to enhance the partition efficiency in high-speed countercurrent chromatography. It consists of a pair of interlocking identical gears, each coaxially holding a pressing wheel to intermittently compress plastic tubing in 0 - 10 mm length at every 1 cm interval. The performance of the processed tubing is examined in protein separation with 1.6 mm ID PTFE tubing intermittently pressed in 3 mm and 10 mm width both at 10 mm intervals at various flow rates and revolution speeds. A series of experiments was performed with a polymer phase system composed of polyethylene glycol and dibasic potassium phosphate each at 12.5% (w/w) in deionized water using three protein samples. Overall results clearly demonstrate that the compressed tubing can yield substantially higher peak resolution than the non-processed tubing. The simple tubing modifier is very useful for separation of proteins with high-speed countercurrent chromatography.
Ohki, Tomohiro; Nakagawa, Atsuhiro; Hirano, Takayuki; Hashimoto, Tokitada; Menezes, Viren; Jokura, Hidefumi; Uenohara, Hiroshi; Sato, Yasuhiko; Saito, Tsutomu; Shirane, Reizo; Tominaga, Teiji; Takayama, Kazuyoshi
2004-01-01
Although water jet technology has been considered as a feasible neuroendoscopic dissection methodology because of its ability to perform selective tissue dissection without thermal damage, problems associated with continuous use of water and the ensuing fountain-effect-with catapulting of the tissue-could make water jets unsuitable for endoscopic use, in terms of safety and ease of handling. Therefore, the authors experimented with minimization of water usage during the application of a pulsed holmium:yttrium-aluminum-garnet (Ho:YAG) laser-induced liquid jet (LILJ), while assuring the dissection quality and the controllability of a conventional water jet dissection device. We have developed the LILJ generator for use as a rigid neuroendoscope, discerned its mechanical behavior, and evaluated its dissection ability using the cadaveric rabbit ventricular wall. The LILJ generator is incorporated into the tip of a stainless steel tube (length: 22 cm; internal diameter: 1.0 mm; external diameter: 1.4 mm), so that the device can be inserted into a commercial, rigid neuroendoscope. Briefly, the LILJ is generated by irradiating an internally supplied water column within the stainless steel tube using the pulsed Ho:YAG laser (wave length: 2.1 microm, pulse duration time: 350 microseconds) and is then ejected through the metal nozzle (internal diameter: 100 microm). The Ho:YAG laser pulse energy is conveyed through optical quartz fiber (core diameter: 400 microm), while cold water (5 degrees C) is internally supplied at a rate of 40 ml/hour. The relationship between laser energy (range: 40-433 mJ/pulse), standoff distance (defined as the distance between the tip of the optical fiber and the nozzle end; range: 10-30 mm), and the velocity, shape, pressure, and average volume of the ejected jet were analyzed by means of high-speed camera, PVDF needle hydrophone, and digital scale. The quality of the dissection plane, the preservation of blood vessels, and the penetration depth were evaluated using five fresh cadaveric rabbit ventricular walls, under neuroendoscopic vision. Jet velocity (7.0-19.6 m/second) and pressure (0.07-0.28 MPa) could be controlled by varying the laser energy, which determined the penetration depth in the cadaveric rabbit ventricular wall (0.07-1.30 mm/shot). The latter could be cut into desirable shapes-without thermal effects-under clear neuroendoscopic vision. The average volume of a single ejected jet could be confined to 0.42-1.52 microl/shot, and there was no accompanying generation of shock waves. Histological specimens revealed a sharp dissection plane and demonstrated that blood vessels of diameter over 100 microm could be preserved, without thermal damage. The present pulsed LILJ system holds promise as a safe and reliable dissection device for deployment in a rigid neuroendoscope. Copyright 2004 Wiley-Liss, Inc.
Ari, Arzu; Harwood, Robert J; Sheard, Meryl M; Fink, James B
2012-07-01
Previous research reporting factors influencing aerosol delivery in intubated patients has been largely focused on the endotracheal tube (ETT) during mechanical ventilation, with little comparative analysis of effect of types of artificial airways and their interfaces on aerosol delivery during spontaneous breathing. The purpose of this study was to compare aerosol delivery via tracheostomy tube (TT) and ETT, using interfaces such as T-piece, tracheostomy collar, and manual resuscitation bag. A teaching manikin was intubated with either an ETT (8.0 mm inner diameter) and TT (8 mm inner diameter). Both bronchi were connected to a collecting filter, attached to a sinusoidal pump simulating the breathing pattern of a spontaneously breathing adult (tidal volume 450 mL, respiratory rate 20 breaths/min, inspiratory-expiratory ratio 1:2). Albuterol sulfate (2.5 mg/3 mL) was nebulized through a jet nebulizer, using each airway and interface as appropriate (n = 3). Drug on the filter was eluted and analyzed with spectrophotometry, and expressed as mean percent of loaded dose delivered. Descriptive statistics, the Student t test, and one-way analysis of variance were applied. A greater percentage of nominal dose was delivered via TT than ETT with both T-piece (13.79 ± 2.59% vs 9.05 ± 0.70%) and manual resuscitation bag (45.75 ± 1.8% vs 27.23 ± 8.98%, P = .038 and P = .025, respectively). Use of manual resuscitation bag with both TT and ETT increased lung dose more than 3-fold. Inhaled dose with tracheostomy collar was (6.92 ± 0.81%) less than T-piece with TT (P = .01). In this adult model of spontaneous ventilation, aerosol therapy through ETT was less efficient than TT, while the manual resuscitation bag was more efficient than T-piece or tracheostomy collar.
Thulium fiber laser recanalization of occluded ventricular catheters in an ex vivo tissue model
NASA Astrophysics Data System (ADS)
Hutchens, Thomas C.; Gonzalez, David A.; Hardy, Luke A.; McLanahan, C. Scott; Fried, Nathaniel M.
2017-04-01
Hydrocephalus is a chronic medical condition that occurs in individuals who are unable to reabsorb cerebrospinal fluid (CSF) created within the ventricles of the brain. Treatment requires excess CSF to be diverted from the ventricles to another part of the body, where it can be returned to the vascular system via a shunt system beginning with a catheter within the ventricle. Catheter failures due to occlusion by brain tissues commonly occur and require surgical replacement of the catheter. In this preliminary study, minimally invasive clearance of occlusions is explored using an experimental thulium fiber laser (TFL), with comparison to a conventional holmium: yttrium aluminium garnet (YAG) laser. The TFL utilizes smaller optical fibers (<200-μm OD) compared with holmium laser (>450-μm OD), providing critical extra cross-sectional space within the 1.2-mm-inner-diameter ventricular catheter for simultaneous application of an endoscope for image guidance and a saline irrigation tube for visibility and safety. TFL ablation rates using 100-μm core fiber, 33-mJ pulse energy, 500-μs pulse duration, and 20- to 200-Hz pulse rates were compared to holmium laser using a 270-μm core fiber, 325-mJ, 300-μs, and 10 Hz. A tissue occluded catheter model was prepared using coagulated egg white within clear silicone tubing. An optimal TFL pulse rate of 50 Hz was determined, with an ablation rate of 150 μm/s and temperature rise outside the catheter of ˜10°C. High-speed camera images were used to explore the mechanism for removal of occlusions. Image guidance using a miniature, 0.7-mm outer diameter, 10,000 pixel endoscope was explored to improve procedure safety. With further development, simultaneous application of TFL with small fibers, miniature endoscope for image guidance, and irrigation tube for removal of tissue debris may provide a safe, efficient, and minimally invasive method of clearing occluded catheters in the treatment of hydrocephalus.
Two-phase heat transfer and pressure drop of LNG during saturated flow boiling in a horizontal tube
NASA Astrophysics Data System (ADS)
Chen, Dongsheng; Shi, Yumei
2013-12-01
Two-phase heat transfer and pressure drop of LNG (liquefied natural gas) have been measured in a horizontal smooth tube with an inner diameter of 8 mm. The experiments were conducted at inlet pressures from 0.3 to 0.7 MPa with a heat flux of 8-36 kW m-2, and mass flux of 49.2-201.8 kg m-2 s-1. The effect of vapor quality, inlet pressure, heat flux and mass flux on the heat transfer characteristic are discussed. The comparisons of the experimental data with the predicted value by existing correlations are analyzed. Zou et al. (2010) correlation shows the best accuracy with 24.1% RMS deviation among them. Moreover four frictional pressure drop methods are also chosen to compare with the experimental database.
Pulse tube cryocooler for IR applications
NASA Astrophysics Data System (ADS)
Korf, H.; Ruhlich, I.; Mai, M.; Thummes, G.
2005-05-01
Pulse tube cryocoolers (PTC) can be regarded as the next step in the development of the Stirling cooler. The major advantage vs. the Stirling cooler is the omission of any moving part in the cold head, resulting in significantly increased MTTF. Further advantages are higher mechanical robustness and stability and the potential for cost reduction. AIM developed PTC's for several years in close cooperation with the University of Giessen. As a recent result at AIM, Coaxial PTC cold head are available within the outline dimension of typical IR Stirling cold head of 13mm diameter. The achieved performance data are comparable to the serial data of the Stirling cold head. This PTC cold head is designed to be operated in the orifice mode without a double inlet which is known to cause instabilities. Technical details and performance data represent the current technical status at AIM.
Study on a neon cryogenic oscillating heat pipe with long heat transport distance
NASA Astrophysics Data System (ADS)
Liang, Qing; Li, Yi; Wang, Qiuliang
2018-06-01
An experimental study is carried out to study the heat transfer characteristics of a cryogenic oscillating heat pipe (OHP) with long heat transport distance. The OHP is made up of a capillary tube with an inner diameter of 1.0 mm and an outer diameter of 2.0 mm. The working fluid is neon, and the length of the adiabatic section is 480 mm. Tests are performed with the different heat inputs, liquid filling ratios and condenser temperature. For the cryogenic OHP with a liquid filling ratio of 30.7% at the condenser temperature of 28 K, the effective thermal conductivity is 3466-30,854 W/m K, and the maximum transfer power is 35.60 W. With the increment of the heat input, the effective thermal conductivity of the cryogenic OHP increases at the liquid filling ratios of 30.7% and 38.5%, while it first increases and then decreases at the liquid filling ratios of 15.2% and 23.3%. Moreover, the effective thermal conductivity increases with decreasing liquid filling ratio at the small heat input, and the maximum transfer power first increases and then decreases with increasing liquid filling ratio. Finally, it is found that the thermal performance of the cryogenic OHP can be improved by increasing the condenser temperature.
NASA Astrophysics Data System (ADS)
Wang, N.; Meissner, M. V.; MacKinnon, N.; Luchnikov, V.; Mager, D.; Korvink, J. G.
2018-02-01
We present a new fabrication process to create sub-mm micro tubes with embedded conductive patterns. Based on common 2D patterning techniques and a specially designed rolling process, it achieves 3D structures featuring potentially complex, embedded electrical, mechanical and micro-fluidic functions. We demonstrate the advantage in creating freeform electrical conductors around sub-mm tubes, such as needed for a tube-integrated micro heater. The production of the 2D patterns is flexible, and we demonstrate that both additive manufacturing (fast, accessible) and conventional micro-fabrication processes (cleanroom, wafer-scale) are compatible with the rolling process. To adapt the rolling process for high frequency applications, the patterned tracks can be directly electroplated, with good adhesion, to reduce electrical resistance. For the first time, we achieve saddle-geometry NMR micro detectors. They feature 100 μm wide, 10 μm thick conductive tracks on 25 μm thick polyimide film, and were successfully tested in a 500 MHz (11.7 T) NMR spectrometer. Using a 620 μm diameter coil, we measured the single-shot SNR of deionized water sample, which corresponded to a mole sensitivity of 18.78 nmolHz-1/2 , and a water line shape of 1.52/26.8/37.3 Hz (50, 0.55, 0.11% of the maximum height) from a sample volume of only 82 nl.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cinson, Anthony D.; Crawford, Susan L.; MacFarlan, Paul J.
2011-07-31
Ultrasonic phased array data were collected on a removed-from-service CRDM nozzle specimen to assess a previously reported leak path. First a mock-up CRDM specimen was evaluated that contained two 0.076-mm (3.0-mil) interference fit regions formed from an actual Inconel CRDM tube and two 152.4-mm (6.0-in.) thick carbon steel blocks. One interference fit region has a series of precision crafted electric discharge machining (EDM) notches at various lengths, widths, depths, and spatial separations for establishing probe sensitivity, resolution and calibration. The other interference fit has zones of boric acid (crystal form) spaced periodically between the tube and block to represent anmore » actively leaking CRDM nozzle assembly in the field. Ultrasonic phased-array evaluations were conducted using an immersion 8-element annular 5.0-MHz probe from the tube inner diameter (ID). A variety of focal laws were employed to evaluate the interference fit regions and J grove weld, where applicable. Responses from the mock-up specimen were evaluated to determine detection limits and characterization ability as well as contrast the ultrasonic response differences with the presence of boric acid in the fit region. Nozzle 63, from the North Anna Unit-2 nuclear power plant, was evaluated to assess leakage path(s) and was destructively dismantled to allow a visual verification of the leak path(s).« less
An Experimental Study on Shrinkage Strains of Normal-and High-Strength Concrete-Filled Frp Tubes
NASA Astrophysics Data System (ADS)
Vincent, Thomas; Ozbakkaloglu, Togay
2017-09-01
It is now well established that concrete-filled fiber reinforced polymer (FRP) tubes (CFFTs) are an attractive construction technique for new columns, however studies examining concrete shrinkage in CFFTs remain limited. Concrete shrinkage may pose a concern for CFFTs, as in these members the curing of concrete takes place inside the FRP tube. This paper reports the findings from an experimental study on concrete shrinkage strain measurements for CFFTs manufactured with normal- and high-strength concrete (NSC and HSC). A total of 6 aramid FRP (AFRP)-confined concrete specimens with circular cross-sections were manufactured, with 3 specimens each manufactured using NSC and HSC. The specimens were instrumented with surface and embedded strain gauges to monitor shrinkage development of exposed concrete and concrete sealed inside the CFFTs, respectively. All specimens were cylinders with a 152 mm diameter and 305 mm height, and their unconfined concrete strengths were 44.8 or 83.2 MPa. Analysis of the shrinkage measurements from concrete sealed inside the CFFTs revealed that embedment depth and concrete compressive strength only had minor influences on recorded shrinkage strains. However, an analysis of shrinkage measurements from the exposed concrete surface revealed that higher amounts of shrinkage can occur in HSC. Finally, it was observed that shrinkage strains are significantly higher for concrete exposed at the surface compared to concrete sealed inside the CFFTs.
Huber, Birgit; Engelhardt, Sascha; Meyer, Wolfdietrich; Krüger, Hartmut; Wenz, Annika; Schönhaar, Veronika; Tovar, Günter E. M.; Kluger, Petra J.; Borchers, Kirsten
2016-01-01
Blood vessel reconstruction is still an elusive goal for the development of in vitro models as well as artificial vascular grafts. In this study, we used a novel photo-curable cytocompatible polyacrylate material (PA) for freeform generation of synthetic vessels. We applied stereolithography for the fabrication of arbitrary 3D tubular structures with total dimensions in the centimeter range, 300 µm wall thickness, inner diameters of 1 to 2 mm and defined pores with a constant diameter of approximately 100 µm or 200 µm. We established a rinsing protocol to remove remaining cytotoxic substances from the photo-cured PA and applied thio-modified heparin and RGDC-peptides to functionalize the PA surface for enhanced endothelial cell adhesion. A rotating seeding procedure was introduced to ensure homogenous endothelial monolayer formation at the inner luminal tube wall. We showed that endothelial cells stayed viable and adherent and aligned along the medium flow under fluid-flow conditions comparable to native capillaries. The combined technology approach comprising of freeform additive manufacturing (AM), biomimetic design, cytocompatible materials which are applicable to AM, and biofunctionalization of AM constructs has been introduced as BioRap® technology by the authors. PMID:27104576
Confined Impinging Jets in Porous Media
NASA Astrophysics Data System (ADS)
Buonomo, B.; Cirillo, L.; Manca, O.; Mansi, N.; Nardini, S.
2016-09-01
Impinging jets are adopted in drying of textiles, paper, cooling of gas turbine components, freezing of tissue in cryosurgery and manufacturing, electronic cooling. In this paper an experimental investigation is carried out on impinging jets in porous media with the wall heated from below with a uniform heat flux. The fluid is air. The experimental apparatus is made up of a fun systems, a test section, a tube, to reduce the section in a circular section. The tube is long 1.0 m and diameter of 0.012 m. The test section has a diameter of 0.10 m and it has the thickness of 10, 20 and 40 mm. In the test section the lower plate is in aluminum and is heated by an electrical resistance whereas the upper plate is in Plexiglas. The experiments are carried out employing a aluminum foam 40 PPI at three thickness as the test section. Results are obtained in a Reynolds number range from 5100 to 15300 and wall heat flux range from 510 W/m2 to 1400 W/m2. Results are given in terms of wall temperature profiles, local and average Nusselt numbers, pressure drops, friction factor and Richardson number.
Chirality correlation in double-wall carbon nanotubes as studied by electron diffraction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirahara, Kaori; Bandow, Shunji; Kociak, Mathieu
2006-05-15
Structural correlation between two adjacent graphitic layers in double-wall carbon nanotubes (DWNTs) was systematically examined by using electron diffraction. Chiral angles and tube diameters were carefully measured, and the chiral indices of individual DWNTs were accurately determined. As a result, it was found that the interlayer distances of DWNTs were widely distributed in the range between 0.34 and 0.38 nm. Chiralities of the inner and outer tubes tended to be distributed at higher chiral angles, approaching 30 deg., for the tubes with diameter D<{approx}3 nm. On the other hand, for the tubes with D>{approx}3 nm, the chiral angles were widelymore » distributed, covering the chiral map entirely. Therefore, we consider that tubes with small diameters have a tendency to form armchair type. Correlation of chiralities between the inner and outer tubes was found to be random.« less
Diameters of the cavo-sinus-tricuspid area in relation to type I atrial flutter.
Kozłowski, Dariusz; Hreczecha, Jolanta; Skwarek, Magdalena; Piwko, Grzegorz; Kosiński, Adam; Gawrysiak, Marcin; Grzybiak, Marek
2003-05-01
Cardiac arrhythmias have troubled patients and fascinated physicians for centuries. The twentieth century was an era of progress, when the mechanism of cardiac disorders became more commonly recognised. Arrhythmias may be due to abnormalities of automaticity, to abnormalities of conduction, or to a combination of both. In order for re-entry to occur, an area of slowing conduction combined with unidirectional block must be present. Much investigation has centred on the underlying re-entry mechanisms of atrial flutter. In the light of these facts, it would seem that a close acquaintance with the detailed topography of the vena cava orifice (cavo), coronary sinus orifice (sinus) and the attachment of the septal leaflet of the tricuspid valve (tricupid) area could be of great interest, especially for invasive cardiologists. The research was conducted carried out on material consisting of 41 hearts of humans of both sexes from the age of 12 to 80 (6 female, 35 male). Classical macroscopic methods of anatomical evaluation were used. The following measurements were made: the shortest distance between the Eustachian valve and the attachment of the tricuspid valve on the left margin of the coronary sinus orifice (diameter 1), the distance between the attachment of the tricuspid valve and the inferior margin of the sinus orifice (diameter 2), the distance between the Eustachian valve and the attachment of the tricuspid valve on the right margin of the coronary sinus orifice (diameter 3), the distance between the inferior margin of the vena cava inferior and the attachment of the tricuspid valve (diameter 4) and, finally, the diameter between the attachment of the septal cusp of the tricuspid valve and the extemal border of the vena cava inferior (diameter 5). No correlation was found between the age and sex of the three groups of the material. The dimensions of the structure examined were similar in the three groups of hearts. In young adult hearts all the diameters measured ranged from 4 to 47 mm. The average diameters were, respectively: 15.02 mm (diameter 1), 8.97 mm (diameter 2), 17.27 mm (diameter 3), 26.87 mm (diameter 4), 36.42 mm (diameter 5). In the mature adult hearts all the diameters measured ranged from 8 to 45 mm; 18.19 mm (diameter 1), 10.54 mm (diameter 2), 19.95 mm (diameter 3), 28.90 mm (diameter 4), 39.63 mm (diameter 5). In the older adults hearts all the diameters measured ranged from 4 to 47 mm. The average diameters were, respectively: 15.65 mm (diameter 1), 8.70 mm (diameter 2), 7.25 mm (diameter 3), 26.80 mm (diameter 4), 35.85 mm (diameter 5). On the basis of our study we were able to conclude that the diameters of the cavo-sinus-tricuspid area were constant and did not differ significantly within the three (young, mature, old) adult groups examined.
von Spiczak, Jochen; Mannil, Manoj; Peters, Benjamin; Hickethier, Tilman; Baer, Matthias; Henning, André; Schmidt, Bernhard; Flohr, Thomas; Manka, Robert; Maintz, David; Alkadhi, Hatem
2018-05-23
The aims of this study were to assess the value of a dedicated sharp convolution kernel for photon counting detector (PCD) computed tomography (CT) for coronary stent imaging and to evaluate to which extent iterative reconstructions can compensate for potential increases in image noise. For this in vitro study, a phantom simulating coronary artery stenting was prepared. Eighteen different coronary stents were expanded in plastic tubes of 3 mm diameter. Tubes were filled with diluted contrast agent, sealed, and immersed in oil calibrated to an attenuation of -100 HU simulating epicardial fat. The phantom was scanned in a modified second generation 128-slice dual-source CT scanner (SOMATOM Definition Flash, Siemens Healthcare, Erlangen, Germany) equipped with both a conventional energy integrating detector and PCD. Image data were acquired using the PCD part of the scanner with 48 × 0.25 mm slices, a tube voltage of 100 kVp, and tube current-time product of 100 mAs. Images were reconstructed using a conventional convolution kernel for stent imaging with filtered back-projection (B46) and with sinogram-affirmed iterative reconstruction (SAFIRE) at level 3 (I463). For comparison, a dedicated sharp convolution kernel with filtered back-projection (D70) and SAFIRE level 3 (Q703) and level 5 (Q705) was used. The D70 and Q70 kernels were specifically designed for coronary stent imaging with PCD CT by optimizing the image modulation transfer function and the separation of contrast edges. Two independent, blinded readers evaluated subjective image quality (Likert scale 0-3, where 3 = excellent), in-stent diameter difference, in-stent attenuation difference, mathematically defined image sharpness, and noise of each reconstruction. Interreader reliability was calculated using Goodman and Kruskal's γ and intraclass correlation coefficients (ICCs). Differences in image quality were evaluated using a Wilcoxon signed-rank test. Differences in in-stent diameter difference, in-stent attenuation difference, image sharpness, and image noise were tested using a paired-sample t test corrected for multiple comparisons. Interreader and intrareader reliability were excellent (γ = 0.953, ICCs = 0.891-0.999, and γ = 0.996, ICCs = 0.918-0.999, respectively). Reconstructions using the dedicated sharp convolution kernel yielded significantly better results regarding image quality (B46: 0.4 ± 0.5 vs D70: 2.9 ± 0.3; P < 0.001), in-stent diameter difference (1.5 ± 0.3 vs 1.0 ± 0.3 mm; P < 0.001), and image sharpness (728 ± 246 vs 2069 ± 411 CT numbers/voxel; P < 0.001). Regarding in-stent attenuation difference, no significant difference was observed between the 2 kernels (151 ± 76 vs 158 ± 92 CT numbers; P = 0.627). Noise was significantly higher in all sharp convolution kernel images but was reduced by 41% and 59% by applying SAFIRE levels 3 and 5, respectively (B46: 16 ± 1, D70: 111 ± 3, Q703: 65 ± 2, Q705: 46 ± 2 CT numbers; P < 0.001 for all comparisons). A dedicated sharp convolution kernel for PCD CT imaging of coronary stents yields superior qualitative and quantitative image characteristics compared with conventional reconstruction kernels. Resulting higher noise levels in sharp kernel PCD imaging can be partially compensated with iterative image reconstruction techniques.
Wu, Naijun; Bradley, Ashley C; Welch, Christopher J; Zhang, Li
2012-08-01
Effects of extra-column volume on apparent separation parameters were studied in ultra-high pressure liquid chromatography with columns and inlet connection tubings of various internal diameters (id) using 50-mm long columns packed with 1.8-μm particles under isocratic conditions. The results showed that apparent retention factors were on average 5, 11, 18, and 41% lower than those corrected with extra-column volumes for 4.6-, 3.0-, 2.1-, and 1.0-mm id columns, respectively, when the extra-column volume (11.3 μL) was kept constant. Also, apparent pressures were 31, 16, 12, and 10% higher than those corrected with pressures from extra-column volumes for 4.6-, 3.0-, 2.1-, and 1.0-mm id columns at the respective optimum flow rate for a typical ultra-high pressure liquid chromatography system. The loss in apparent efficiency increased dramatically from 4.6- to 3.0- to 2.1- to 1.0-mm id columns, less significantly as retention factors increased. The column efficiency was significantly improved as the inlet tubing id was decreased for a given column. The results suggest that maximum ratio of extra-column volume to column void volume should be approximately 1:10 for column porosity more than 0.6 and a retention factor more than 5, where 80% or higher of theoretically predicted efficiency could be achieved. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Investigation of saturated critical heat flux in a single, uniformly heated microchannel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wojtan, Leszek; Revellin, Remi; Thome, John R.
2006-08-15
A series of tests have been performed to determine the saturated critical heat flux (CHF) in 0.5 and 0.8mm internal diameter microchannel tubes as a function of refrigerant mass velocity, heated length, saturation temperature and inlet liquid subcooling. The tested refrigerants were R-134a and R-245fa and the heated length of microchannel was varied between 20 and 70mm. The results show a strong dependence of CHF on mass velocity, heated length and microchannel diameter but no influence of liquid subcooling (2-15{sup o}C) was observed. The experimental results have been compared to the well-known CHF single-channel correlation of Y. Katto and H.more » Ohno [An improved version of the generalized correlation of critical heat flux for the forced convective boiling in uniformly heated vertical tubes, Int. J. Heat and Mass Transfer 27 (9) (1984) 1641-1648] and the multichannel correlation of W. Qu and I. Mudawar [Measurement and correlation of critical heat flux in two-phase microchannel heat sinks, Int. J. Heat and Mass Transfer 47 (2004) 2045-2059]. The comparison shows that the correlation of Katto-Ohno predicts microchannel data with a mean absolute error of 32.8% with only 41.2% of the data falling within a +/-15% error band. The correlation of Qu and Mudawar shows the same trends as the CHF data but significantly overpredicts them. Based on the present experimental data, a new microscale version of the Katto-Ohno correlation for the prediction of CHF during saturated boiling in microchannels has been proposed. (author)« less
NASA Astrophysics Data System (ADS)
Zobnin, A. V.; Usachev, A. D.; Petrov, O. F.; Fortov, V. E.; Thoma, M. H.; Fink, M. A.
2018-03-01
The influence of a dust cloud on the structure of the positive column of a direct current gas discharge in a cylindrical glass tube under milligravity conditions has been studied both experimentally and numerically. The discharge was produced in neon at 60 Pa in a glass tube with a diameter of 30 mm at a discharge current 1 mA. Spherical monodisperse melamine formaldehyde dust particles with a diameter of 6.86 μm were injected into the positive column and formed there a uniform dust cloud with a maximum diameter of 14.4 mm. The shape of the cloud and the dust particle number density were measured. The cloud was stationary in the radial direction and slowly drifted in the axial direction. It was found that in the presence of the dust cloud, the intensity of the neon spectral line with a wavelength by 585.25 nm emitted by the discharge plasma increased by 2.3 times and 2 striations appeared on the anode side of the cloud. A numerical simulation of the discharge was performed using the 2D (quasi-3D) nonlocal self-consistent kinetic model of a longitudinally inhomogeneous axially symmetric positive column [Zobnin et al., Phys. Plasmas 21, 113503 (2014)], which was supplemented by a program module performing a self-consistent calculation of dust particle charges, the plasma recombination rate on dust particles, and ion scattering on dust particles. A new approach to the calculation of particle charges and the screening radius in dense dust clouds is proposed. The results of the simulation are presented, compared with experimental data and discussed. It is demonstrated that for the best agreement between simulated and experimental data, it is necessary to take into account the reflection of electrons from the dust particle surface in order to correctly describe the recombination rate in the cloud, its radial stability, and the dust particle charges.
Concept definition study for an extremely large aerophysics range facility
NASA Technical Reports Server (NTRS)
Swift, Hallock F.
1993-01-01
A conceptual design of a very large aeroballistic range is presented, as are its operational characteristics and procedures. The proposed model launcher is a two-stage light-gas gun, having a launch tube diameter of 254 mm, and the capability of accelerating a 14 kg launch mass to 6.1 km/sec. The gun's 91.4 cm diameter piston is driven by pressurized helium. High pressures in the central breech are contained by a multiple disk arrangement. The blast tank and sabot separation tank are described, as are methods for arresting sabot segments. The conceptual design of the range itself includes a 3.3 m diameter test or flight chamber some 330 m in length. Provisions are made for testing of free flight models and tests in which the model is confined by a track system. Methods for model deceleration and recovery are described. Provisions required for future addition of advanced model launchers such as an electromagnetic launcher or ram accelerator are addressed. Siting and safety issues are also addressed.
a Compact, Rf-Driven Pulsed Ion Source for Intense Neutron Generation
NASA Astrophysics Data System (ADS)
Perkins, L. T.; Celata, C. M.; Lee, Y.; Leung, K. N.; Picard, D. S.; Vilaithong, R.; Williams, M. D.; Wutte, D.
1997-05-01
Lawrence Berkeley National Laboratory is currently developing a compact, sealed-accelerator-tube neutron generator capable of producing a neutron flux in the range of 109 to 1010 D-T neutrons per second. The ion source, a miniaturized variation of earlier 2 MHz radio-frequency (rf)-driven multicusp ion sources, is designed to fit within a #197# 5 cm diameter borehole. Typical operating parameters include repetition rates up to 100 pps, with pulse widths between 10 and 80 us and source pressures as low as #197# 5 mTorr. In this configuration, peak extractable hydrogen current exceeding 35 mA from a 2 mm diameter aperture together with H1+ yields over 94% have been achieved. The required rf impedance matching network has been miniaturized to #197# 5 cm diameter. The accelerator column is a triode design using the IGUN ion optics codes and allows for electron suppression. Results from the testing of the integrated matching network-ion source-accelerator system will be presented.
NASA Astrophysics Data System (ADS)
Punia, Sanjeev Singh; Singh, Jagdev
2015-11-01
This paper presents an experimental investigation for the flow of liquefied petroleum gas (LPG) as a refrigerant inside an adiabatic helically coiled capillary tube in vapour compression refrigeration system. The effect of various geometric parameters and operating conditions like capillary tube inner diameter, length of capillary tube, coil diameter and different inlet subcoolings on the mass flow rate of LPG through the helical coiled capillary tube geometry has been investigated. It has been established that the coil diameter significantly influences the mass flow rate of LPG through the adiabatic helical capillary tube. It has been concluded that the effect of coiling of capillary tube reduces the mass flow rate by 5-12 % as compared to those of the straight capillary tube operating under similar conditions. The data obtained from the experiments are analyzed and a dimensionless correlation has been developed. The proposed correlation predicts that more than 90 % of experimental data which is in agreement with measured data in an error band of ±10 %.
NASA Astrophysics Data System (ADS)
Shibahara, Makoto; Fukuda, Katsuya; Liu, Qiusheng; Hata, Koichi
2018-02-01
The heat transfer characteristics of forced convection for subcooled water in small tubes were clarified using the commercial computational fluid dynamic (CFD) code, PHENICS ver. 2013. The analytical model consists of a platinum tube (the heated section) and a stainless tube (the non-heated section). Since the platinum tube was heated by direct current in the authors' previous experiments, a uniform heat flux with the exponential function was given as a boundary condition in the numerical simulation. Two inner diameters of the tubes were considered: 1.0 and 2.0 mm. The upward flow velocities ranged from 2 to 16 m/s and the inlet temperature ranged from 298 to 343 K. The numerical results showed that the difference between the surface temperature and the bulk temperature was in good agreement with the experimental data at each heat flux. The numerical model was extended to the liquid sublayer analysis for the CHF prediction and was evaluated by comparing its results with the experimental data. It was postulated that the CHF occurs when the fluid temperature near the heated wall exceeds the saturated temperature, based on Celata et al.'s superheated layer vapor replenishment (SLVR) model. The suggested prediction method was in good agreement with the experimental data and with other CHF data in literature within ±25%.
Bactericial effect of a non-thermal plasma needle against Enterococcus faecalis biofilms
NASA Astrophysics Data System (ADS)
Jiang, Chunqi; Schaudinn, C.; Jaramillo, D. E.; Sedghizadeh, P. P.; Webster, P.; Costerton, J. W.
2011-10-01
Up to 3 cm long submillimeter-in-scale plasma needle was generated in ambient atmosphere for root canal disinfection. Powered with 1-2 kHz, multi-kilovolt nanosecond electric pulses, this He/(1%)O2 plasma jet consists of ionization fronts propagating at speeds of the order of 107 cm/s. Plasma treatment of Enterococcus faecalis biofilms on hydroxyapatite (HA) discs for 5 min resulted in severe damage of the bacterial cells and sterilized HA surfaces of more than 3 mm in diameter, observed by the scanning electron microscopy. With a curing dielectric microtube placed 1 cm or less below the nozzle, the plasma jet entered even at a sharp angle and followed the curvature of the tube, and reached the bottom of the tube. The bactericidal effect of the plasma needle against E. faecalis biofilm grown on the inner surfaces of the tube was demonstrated. However, the bactericidal effect weakens or diminishes for the bacteria grown deeper in the tube, indicating improvement of the plasma treatment scheme is needed. Mechanisms of the plasma bactericidal effects are discussed. Supported by the National Institute of Dental and Craniofacial Research and the Air Force Office of Scientific Research.
Dose and image quality for a cone-beam C-arm CT system.
Fahrig, Rebecca; Dixon, Robert; Payne, Thomas; Morin, Richard L; Ganguly, Arundhuti; Strobel, Norbert
2006-12-01
We assess dose and image quality of a state-of-the-art angiographic C-arm system (Axiom Artis dTA, Siemens Medical Solutions, Forchheim, Germany) for three-dimensional neuro-imaging at various dose levels and tube voltages and an associated measurement method. Unlike conventional CT, the beam length covers the entire phantom, hence, the concept of computed tomography dose index (CTDI) is not the metric of choice, and one can revert to conventional dosimetry methods by directly measuring the dose at various points using a small ion chamber. This method allows us to define and compute a new dose metric that is appropriate for a direct comparison with the familiar CTDIw of conventional CT. A perception study involving the CATPHAN 600 indicates that one can expect to see at least the 9 mm inset with 0.5% nominal contrast at the recommended head-scan dose (60 mGy) when using tube voltages ranging from 70 kVp to 125 kVp. When analyzing the impact of tube voltage on image quality at a fixed dose, we found that lower tube voltages gave improved low contrast detectability for small-diameter objects. The relationships between kVp, image noise, dose, and contrast perception are discussed.
Analyses of Nb-1Zr/C-103, vapor anode, multi-tube AMTEC cells
NASA Astrophysics Data System (ADS)
King, Jeffrey C.; El-Genk, Mohamed S.
2000-01-01
A high performance, Nb-1Zr/C-103, vapor anode, multi-tube AMTEC cell design is presented. The cell measures 41.27 mm in diameter, is 125.3 mm high, and has eight BASE tubes connected electrically in series. The hot structure of the cell (hot plate, BASE tubes support plate, hot plenum wall, evaporator standoff, evaporator wick, and side wall facing the BASE tubes) is made of Nb-1Zr. The cold structure of the cell (condenser, interior cylindrical thermal radiation shield, the casing and the wick of the liquid sodium return artery, and side wall above the BASE tubes) is made of the stronger, lower thermal conductivity niobium alloy C-103. This cell, which weighs 163.4 g, could deliver 7.0 We at 17% efficiency and load voltage of 3.3 V, when using TiN BASE electrodes characterized by B=75 A.K1/2/m2.Pa and G=50 and assuming BASE/electrode contact resistance of 0.06 Ω-cm2 and leakage resistance of the BASE braze structure of 3 Ω. For these performance parameters and when the interior cylindrical C-103 thermal radiation shield is covered with low emissivity rhodium, the projected specific mass of the cell is 23.4 g/We. The BASE brazes and the evaporator temperatures were below the recommended limits of 1123 K and 1023 K, respectively. In addition, the temperature margin in the cell was at least + 20 K. When electrodes characterized by B=120 A.K1/2/m2.Pa and G=10 were used, the cell power increased to 8.38 We at 3.5 V and efficiency of 18.8%, for a cell specific mass of 19.7 g/We. Issues related to structure strength of the cell and the performance degradation of the BASE and electrodes are not addressed in this paper. .
Bifurcation parameters of a reflected shock wave in cylindrical channels of different roughnesses
NASA Astrophysics Data System (ADS)
Penyazkov, O.; Skilandz, A.
2018-03-01
To investigate the effect of bifurcation on the induction time in cylindrical shock tubes used for chemical kinetic experiments, one should know the parameters of the bifurcation structure of a reflected shock wave. The dynamics and parameters of the shock wave bifurcation, which are caused by reflected shock wave-boundary layer interactions, are studied experimentally in argon, in air, and in a hydrogen-nitrogen mixture for Mach numbers M = 1.3-3.5 in a 76-mm-diameter shock tube without any ramp. Measurements were taken at a constant gas density behind the reflected shock wave. Over a wide range of experimental conditions, we studied the axial projection of the oblique shock wave and the pressure distribution in the vicinity of the triple Mach configuration at 50, 150, and 250 mm from the endwall, using side-wall schlieren and pressure measurements. Experiments on a polished shock tube and a shock tube with a surface roughness of 20 {μ }m Ra were carried out. The surface roughness was used for initiating small-scale turbulence in the boundary layer behind the incident shock wave. The effect of small-scale turbulence on the homogenization of the transition zone from the laminar to turbulent boundary layer along the shock tube perimeter was assessed, assuming its influence on a subsequent stabilization of the bifurcation structure size versus incident shock wave Mach number, as well as local flow parameters behind the reflected shock wave. The influence of surface roughness on the bifurcation development and pressure fluctuations near the wall, as well as on the Mach number, at which the bifurcation first develops, was analyzed. It was found that even small additional surface roughness can lead to an overshoot in pressure growth by a factor of two, but it can stabilize the bifurcation structure along the shock tube perimeter.
Shiqing, Liu; Wenxu, Qi; Jin, Zhang; Youjing, Dong
2018-04-01
The aims of this study were to measure diameters of the cricoid ring and left main bronchus in Asian adult patients and to assess the accuracy of double lumen tube size selected according to cricoid and left main bronchus diameter, respectively. Retrospective observational study. Academic, tertiary care hospital. Preoperative CT scans from 87 men and 94 women who had undergone general anesthesia for lung operations. No intervention. The diameters of the cricoid ring and left main bronchus were measured from thoracic computed tomography images after correction of slant. The "best-fit" size of double lumen tube was determined by comparing diameter of the left main bronchus and cricoid ring with the diameter of the double lumen tube. Diameters of the cricoid ring and left main bronchus were both significantly greater in men compared with women (p < 0.0001). Shapes of cricoid rings were different between genders (p < 0.0001), while shapes of the left main bronchus were not significant different (p = 0.343). With reference to the "best fit" size, the rate of agreement of cricoid ring size, left main bronchus size, and height size for men were 100%, 100%, and 94.3%. For women, the rate of agreement of cricoid ring size, left main bronchus size, and height size were 94.7%, 63.8%, and 51.1%. The "best fit" size of a double lumen tube should be decided by a combination of diameters of the cricoid ring and the left main bronchus. Copyright © 2017 Elsevier Inc. All rights reserved.
Catalyzed Combustion In Micro-Propulsion Devices: Project Status
NASA Technical Reports Server (NTRS)
Sung, C. J.; Schneider, S. J.
2003-01-01
In recent years, there has been a tendency toward shrinking the size of spacecraft. New classes of spacecraft called micro-spacecraft have been defined by their mass, power, and size ranges. Spacecraft in the range of 20 to 100 kg represent the class most likely to be utilized by most small sat users in the near future. There are also efforts to develop 10 to 20 kg class spacecraft for use in satellite constellations. More ambitious efforts will be to develop spacecraft less than 10 kg, in which MEMS fabrication technology is required. These new micro-spacecraft will require new micro-propulsion technology. Although micro-propulsion includes electric propulsion approaches, the focus of this proposed program is micro-chemical propulsion which requires the development of microcombustors. As combustors are scaled down, the surface to volume ratio increases. The heat release rate in the combustor scales with volume, while heat loss rate scales with surface area. Consequently, heat loss eventually dominates over heat release when the combustor size becomes smaller, thereby leading to flame quenching. The limitations imposed on chamber length and diameter has an immediate impact on the degree of miniaturization of a micro-combustor. Before micro-combustors can be realized, such a difficulty must be overcome. One viable combustion alternative is to take advantage of surface catalysis. Micro-chemical propulsion for small spacecraft can be used for primary thrust, orbit insertion, trajectory-control, and attitude control. Grouping micro-propulsion devices in arrays will allow their use for larger thrust applications. By using an array composed of hundreds or thousands of micro-thruster units, a particular configuration can be arranged to be best suited for a specific application. Moreover, different thruster sizes would provide for a range of thrust levels (from N s to mN s) within the same array. Several thrusters could be fired simultaneously for thrust levels higher than the basic units, or in a rapid sequence in order to provide gradual but steady low-g acceleration. These arrays of micro-propulsion systems would offer unprecedented flexibility and redundancy for satellite propulsion and reaction control for launch vehicles. A high-pressure bi-propellant micro-rocket engine is already being developed using MEMS technology. High pressure turbopumps and valves are to be incorporated onto the rocket chip . High pressure combustion of methane and O2 in a micro-combustor has been demonstrated without catalysis, but ignition was established with a spark. This combustor has rectangular dimensions of 1.5 mm by 8 mm (hydraulic diameter 3.9 mm) and a length of 4.5 mm and was operated at 1250 kPa with plans to operate it at 12.7 MPa. These high operating pressures enable the combustion process in these devices, but these pressures are not practical for pressure fed satellite propulsion systems. Note that the use of these propellants requires an ignition system and that the use of a spark would impose a size limitation to this micro-propulsion device because the spark unit cannot be shrunk proportionately with the thruster. Results presented in this paper consist of an experimental evaluation of the minimum catalyst temperature for initiating/supporting combustion in sub-millimeter diameter tubes. The tubes are resistively heated and reactive premixed gases are passed through the tubes. Tube temperature and inlet pressure are monitored for an indication of exothermic reactions and composition changes in the gases.
Observation of Possible Lava Tube Skylights by SELENE cameras
NASA Astrophysics Data System (ADS)
Haruyama, Junichi; Hiesinger, Harald; van der Bogert, Carolyn
We have discovered three deep hole-structures on the Moon in the Terrain Camera and Multi-band Imager on the SELENE. These holes are large depth to diameter ratios: Marius Hills Hole (MHH) is 65 m in diameter and 88-90 m in depth, Mare Tranquillitatis Hole (MTH) is 120 x 110 m in diameter and 180 m in depth, and Mare Ingenii Hole (MIH) is 140 x 110 m in diameter and deeper than 90 m. No volcanic material from the holes nor dike-relating pit craters is seen around the holes. They are possible lava tube skylights. These holes and possibly connected tubes have a lot of scientific interests and high potentialities as lunar bases.
Intraluminal pressure response in Baerveldt tube shunts: a comparison of modification techniques.
Gilbert, David D; Bond, Brent
2007-01-01
To design an apparatus for in vitro quantification of effects of modifications to nonvalved tube shunts, and to compare the effects of these modifications done to prevent early postoperative hypotony. A testing apparatus was designed and constructed to measure intraluminal pressure (ILP) during constant infusion of balanced salt solution at 2 microL/min through Baerveldt tube shunts mounted on cadaver eyes. Three different modifications were performed and 3 shunts were used for each modification. The modifications were partial tube occlusion with a 3-0 Supramid suture, tube perforation with a 27-gauge needle on an occluded tube, and a 1.2 mm longitudinal venting slit on an occluded tube. The final steady state ILP for the 3-0 Supramid partially occluded tube ranged between 1.6 and 2.8 mm Hg over 3 trials with an average final steady state ILP of 2.0 mm Hg. The 27-gauge needle perforation produced ILPs of 4.6 to 8.2 mm Hg over 3 trials with an average final steady state pressure of 5.9 mm Hg. The 1.2 mm longitudinal venting slit produced an ILP range of 12.6 to 17.3 mm Hg over 3 trials with an average final steady state ILP of 14.8 mm Hg. The differences in final steady state ILP between the 3 modification techniques were statistically significant (P=0.00036). The 3-0 Supramid occlusion and the 27-gauge perforation techniques produced hypotony, whereas the 1.2 mm longitudinal venting slit produced acceptable pressures in vitro.
NASA Astrophysics Data System (ADS)
Ilinca, A.; Mangini, D.; Mameli, M.; Fioriti, D.; Filippeschi, S.; Araneo, L.; Roth, N.; Marengo, M.
2017-11-01
A Novel Single Loop Pulsating Heat Pipe (SLPHP), with an inner diameter of 2 mm, filled up with two working fluids (Ethanol and FC-72, Filling Ratio of 60%), is tested in Bottom Heated mode varying the heating power and the orientation. The static confinement diameter for Ethanol and FC-72, respectively 3.4 mm and 1.7mm, is above and slightly under the inner diameter of the tube. This is important for a better understanding of the working principle of the device very close to the limit between the Loop Thermosyphon and Pulsating Heat Pipe working modes. With respect to previous SLPHP experiments found in the literature, such device is designed with two transparent inserts mounted between the evaporator and the condenser allowing direct fluid flow visualization. Two highly accurate pressure transducers permit local pressure measurements just at the edges of one of the transparent inserts. Additionally, three heating elements are controlled independently, so as to vary the heating distribution at the evaporator. It is found that peculiar heating distributions promote the slug/plug flow motion in a preferential direction, increasing the device overall performance. Pressure measurements point out that the pressure drop between the evaporator and the condenser are related to the flow pattern. Furthermore, at high heat inputs, the flow regimes recorded for the two fluids are very similar, stressing that, when the dynamic effects start to play a major role in the system, the device classification between Loop Thermosyphon and Pulsating Heat Pipe is not that sharp anymore.
Miniature fiber optic loop subcomponent for compact sensors and dense routing
NASA Astrophysics Data System (ADS)
Gillham, Frederick J.; Stowe, David W.; Ouellette, Thomas R.; Pryshlak, Adrian P.
1999-05-01
Fiber optic data links and embedded sensors, such as Fabry- Perot and Mach-Zehnders, are important elements in smart structure architectures. Unfortunately, one problem with optical fiber is the inherent limit through which fibers and cables can be looped. A revolutionary, patented technology has been developed which overcomes this problem. Based on processing the fiber into low loss miniature bends, it permits routing the fiber to difficult areas, and minimizing the size of sensors and components. The minimum bend diameter for singlemode fiber is typically over two inches in diameter, to avoid light attenuation and limit stresses which could prematurely break the fiber. With the new miniature bend technology, bend diameters as small as 1 mm are readily achieved. One embodiment is a sub-component with standard singlemode fiber formed into a 180 degree bend and packaged in a glass tube only 1.5 mm OD X 8 mm long, Figure 1. Measured insertion loss is less than 0.2 dB from 1260 nm to 1680 nm. A final processing step which anneals the fiber into the eventual curvature, reduces the internal stress, thereby resulting in long life expectancy with robust immunity to external loading. This paper addresses the optical and physical performance of the sub-component. Particular attention is paid to attenuation spectra, polarization dependent loss, reflectance, thermal cycle, damp heat, and shock tests. Applications are presented which employs the bend technology. Concatenating right angle bends into a 'wire harness' demonstrates the ability to route fiber through a smart engine or satellite structure. Miniature optical coils are proposed for sensors and expansion joints.
Relationship between sampling volume of primary serum tubes and spurious hemolysis.
Lippi, Giuseppe; Musa, Roberta; Battistelli, Luisita; Cervellin, Gianfranco
2012-01-01
We planned a study to establish whether spurious hemolysis may be present in low volume tubes or partially filled tubes. Four serum tubes were collected in sequence from 20 healthy volunteers, i.e., 4.0 mL, 13 x 75 mm (discard tube), 6.0 mL, 13 x 100 mm half-filled, 4.0 mL, 13 x 75 mm full-draw and 6.0 mL, 13 x 100 mm full-draw. Serum was separated and immediately tested for hemolysis index (HI), potassium, aspartate aminotransferase (AST), and lactate dehydrogenase (LDH). The HI always remained below the limit of detection of the method (< 0.5 g/L) in all tubes. No statistically significant differences were recorded in any parameter except potassium, which increased by 0.10 mmol/L in 4 mL full-draw tubes. No clinically significant variation was however recorded in any tube. The results suggest that all types of tubes tested might be used interchangeably in term of risk of spurious hemolysis.
NASA Astrophysics Data System (ADS)
Wang, Wei-Wen William
This dissertation is to document experimental, local condensation and single-phase heat transfer and flow data of the minute diameter, microchannel tube and to develop correlation methods for optimizing the design of horizontal-microchannel condensers. It is essential to collect local data as the condensation progresses through several different flow patterns, since as more liquid is formed, the mechanism conducting heat transfer and flow is also changing. Therefore, the identification of the flow pattern is as important as the thermal and dynamic data. The experimental results were compared with correlation and flow regime maps from literature. The experiment using refrigerant HFC-134a in flat, multi-port aluminum tubing with 1.46mm hydraulic diameter was conducted. The characteristic of single-phase friction can be described with the analytical solution of square channel. The Gnielinski correlation provided good prediction of single-phase turbulent flow heat transfer. Higher mass fluxes and qualities resulted in increased condensation heat transfer and were more effective in the shear-dominated annular flow. The effect of temperature gradient from wall to refrigerant attributed profoundly in the gravity-dominated wavy/slug flow. Two correlation based on different flow mechanisms were developed for specified flow regimes. Finally, an asymptotic correlation was successfully proposed to account for the entire data regardless of flow patterns. Data taken from experiment and observations obtained from flow visualization, resulted in a better understanding of the physics in microchannel condensation, optimized designs in the microchannel condensers are now possible.
Wen, Bing; Yang, Junya; Liu, Huiruo; Jiao, Zhouyang; Zhao, Wenzeng
2016-01-01
Objective: To document clinical experience of treating congenital heart disease combined with large patent ductus arteriosus with pulmonary artery closure in combination with patch technique. Methods: Thirty-six patients (8 males and 28 females) who suffered from congenital heart disease and underwent hybrid surgery in the First Affiliated Hospital of Zhengzhou University from October 2010 to February 2014 were selected for this study. They aged 14 to 39 years and weighed 32.20 to 61.50 kg. Diameter of arterial duct was between 10 mm and 13 mm; 28 cases were tube type, 4 cases were funnel type and four cases were window type. All patients had moderate or severe pulmonary arterial hypertension; besides, there were 28 cases of ventricular septal defect, 16 cases of atrial septal defect, eight cases of aortic insufficiency, four cases of mitral stenosis and insufficiency and four cases of infectious endocarditis. Cardz Pulmonary Bypass (CPB) was established after chest was opened along the middle line. With the help of Transesophageal echocardiography, large patent ductus arteriosus was blocked off through pulmonary artery. Pulmonary artery was cut apart after blocking of heart. Large patent ductus arteriosus on the side of pulmonary artery was strengthened with autologous pericardial patch. Results: Of 36 patients, 32 patients had patent ductus arteriosus closure device and four patients had atrial septal defect closure device. Pulmonary arteries of 36 cases were all successfully closed. Systolic pressure declined after closure ((54.86±19.23) mmHg vs (96.05±23.07) mmHg, p<0.05); average pulmonary arterial pressure also declined after closure ((39.15±14.83) mmHg vs (72.88±15.76) mmHg, p<0.05). The patients were followed up for one to fifty one months (average 11.5 months). Compared to before surgery, left atrial diameter, left ventricular diameter and pulmonary artery diameter all narrowed after surgery. Besides, clinical symptoms were relieved and cardiac function of the patients also improved. Conclusion: Hybrid surgery is feasible and safe in treating patients with large patent ductus arteriosus and congenital heart disease, which decreases surgical problems, shortens surgical time and lowers the incidence of complications. PMID:27375685
Wen, Bing; Yang, Junya; Liu, Huiruo; Jiao, Zhouyang; Zhao, Wenzeng
2016-01-01
To document clinical experience of treating congenital heart disease combined with large patent ductus arteriosus with pulmonary artery closure in combination with patch technique. Thirty-six patients (8 males and 28 females) who suffered from congenital heart disease and underwent hybrid surgery in the First Affiliated Hospital of Zhengzhou University from October 2010 to February 2014 were selected for this study. They aged 14 to 39 years and weighed 32.20 to 61.50 kg. Diameter of arterial duct was between 10 mm and 13 mm; 28 cases were tube type, 4 cases were funnel type and four cases were window type. All patients had moderate or severe pulmonary arterial hypertension; besides, there were 28 cases of ventricular septal defect, 16 cases of atrial septal defect, eight cases of aortic insufficiency, four cases of mitral stenosis and insufficiency and four cases of infectious endocarditis. Cardz Pulmonary Bypass (CPB) was established after chest was opened along the middle line. With the help of Transesophageal echocardiography, large patent ductus arteriosus was blocked off through pulmonary artery. Pulmonary artery was cut apart after blocking of heart. Large patent ductus arteriosus on the side of pulmonary artery was strengthened with autologous pericardial patch. Of 36 patients, 32 patients had patent ductus arteriosus closure device and four patients had atrial septal defect closure device. Pulmonary arteries of 36 cases were all successfully closed. Systolic pressure declined after closure ((54.86±19.23) mmHg vs (96.05±23.07) mmHg, p<0.05); average pulmonary arterial pressure also declined after closure ((39.15±14.83) mmHg vs (72.88±15.76) mmHg, p<0.05). The patients were followed up for one to fifty one months (average 11.5 months). Compared to before surgery, left atrial diameter, left ventricular diameter and pulmonary artery diameter all narrowed after surgery. Besides, clinical symptoms were relieved and cardiac function of the patients also improved. Hybrid surgery is feasible and safe in treating patients with large patent ductus arteriosus and congenital heart disease, which decreases surgical problems, shortens surgical time and lowers the incidence of complications.
Role of surfactants in carbon nanotubes density gradient separation.
Carvalho, Elton J F; dos Santos, Maria Cristina
2010-02-23
Several strategies aimed at sorting single-walled carbon nanotubes (SWNT) by diameter and/or electronic structure have been developed in recent years. A nondestructive sorting method was recently proposed in which nanotube bundles are dispersed in water-surfactant solutions and submitted to ultracentrifugation in a density gradient. By this method, SWNTs of different diameters are distributed according to their densities along the centrifuge tube. A mixture of two anionic amphiphiles, namely sodium dodecylsulfate (SDS) and sodium cholate (SC), presented the best performance in discriminating nanotubes by diameter. We present molecular dynamics studies of the water-surfactant-SWNT system. The simulations revealed one aspect of the discriminating power of surfactants: they can actually be attracted toward the interior of the nanotube cage. The binding energies of SDS and SC on the outer nanotube surface are very similar and depend weakly on diameter. The binding inside the tubes, on the contrary, is strongly diameter dependent: SDS fits best inside tubes with diameters ranging from 8 to 9 A, while SC is best accommodated in larger tubes, with diameters in the range 10.5-12 A. The dynamics at room temperature showed that, as the amphiphile moves to the hollow cage, water molecules are dragged together, thereby promoting the nanotube filling. The resulting densities of filled SWNT are in agreement with measured densities.
SPE5 Sub-Scale Test Series Summary Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vandersall, Kevin S.; Reeves, Robert V.; DeHaven, Martin R.
2016-01-14
A series of 2 SPE5 sub-scale tests were performed to experimentally confirm that a booster system designed and evaluated in prior tests would properly initiate the PBXN-110 case charge fill. To conduct the experiments, a canister was designed to contain the nominally 50 mm diameter booster tube with an outer fill of approximately 150 mm diameter by 150 mm in length. The canisters were filled with PBXN-110 at NAWS-China Lake and shipped back to LLNL for testing in the High Explosives Applications Facility (HEAF). Piezoelectric crystal pins were placed on the outside of the booster tube before filling, and amore » series of piezoelectric crystal pins along with Photonic Doppler Velocimetry (PDV) probes were placed on the outer surface of the canister to measure the relative timing and magnitude of the detonation. The 2 piezoelectric crystal pins integral to the booster design were also utilized along with a series of either piezoelectric crystal pins or piezoelectric polymer pads on the top of the canister or outside case that utilized direct contact, gaps, or different thicknesses of RTV cushions to obtain time of arrival data to evaluate the response in preparation for the large-scale SPE5 test. To further quantify the margin of the booster operation, the 1st test (SPE5SS1) was functioned with both detonators and the 2nd test (SPE5SS2) was functioned with only 1 detonator. A full detonation of the material was observed in both experiments as observed by the pin timing and PDV signals. The piezoelectric pads were found to provide a greater measured signal magnitude during the testing with an RTV layer present, and the improved response is due to the larger measurement surface area of the pad. This report will detail the experiment design, canister assembly for filling, final assembly, experiment firing, presentation of the diagnostic results, and a discussion of the results.« less
Weigt, J; Malfertheiner, P
2013-07-01
Until now, it is uncertain if the so-called pH-only reflux episodes that consist of a pH drop without evidence of retrograde bolus movement in multichannel intraluminal impedance (MII) represent reflux episodes or artifacts. Hiatal hernia (HH) may allow reflux of small volumes to occur that can be detected by pH-metry but not by MII. The aim was to search for a mechanism that can explain pH-only reflux, 20 patients (12 females and 8 males, median age 52 years, interquartile range [IQR]: 40.5-60.75 years) were investigated with MII-pH off PPI. Impedance and pH-metry data were analyzed separately. The differences in detection rate of acid reflux between pH-metry and MII were correlated with the presence of HH. In an in vitro experiment, MII-pH probes were flushed with citric acid in plastic tubes of different size with capillary diameter and diameters of 2.5 mm and 4.5 mm, while recording pH values and impedance. HH was present in six patients and absent in 14 patients. In patients with HH in comparison with patients with absent HH, the difference of acid reflux detection between pH-metry and MII is significantly higher (70%, IQR: 15-88% and 3.6%, IQR: 0-31%, respectively). In vitro all simulated reflux lead to a fall in pH whereas a corresponding decrease in impedance was only recognizable in the 4.5-mm plastic tubes. Acid reflux episodes in patients with HH are more frequently detected by pH-metry than by MII. Small volume reflux that does not lead to a decrease in impedance is the likely explanation for this phenomenon. © 2012 Copyright the Authors. Journal compilation © 2012, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.
Letter Report Documenting Progress of Second Generation ATF FeCrAl Alloy Fabrication
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamamoto, Y.; Yang, Y.; Field, K. G.
2014-06-10
Development of the 2nd generation ATF FeCrAl alloy has been initiated, and a candidate alloy was selected for trial tube fabrication through hot-extrusion and gun-drilling processes. Four alloys based on Fe-13Cr-4.5Al-0.15Y in weight percent were newly cast with minor alloying additions of Mo, Si, Nb, and C to promote solid-solution and second-phase precipitate strengthening. The alloy compositions were selected with guidance from computational thermodynamic tools. The lab-scale heats of ~ 600g were arc-melted and drop-cast, homogenized, hot-forged and -rolled, and then annealed producing plate shape samples. An alloy with Mo and Nb additions (C35MN) processed at 800°C exhibits very finemore » sub-grain structure with the sub-grain size of 1-3μm which exhibited more than 25% better yield and tensile strengths together with decent ductility compared to the other FeCrAl alloys at room temperature. It was found that the Nb addition was key to improving thermal stability of the fine sub-grain structure. Optimally, grains of less than 30 microns are desired, with grains up to and order of magnitude in desired produced through Nb addition. Scale-up effort of the C35MN alloy was made in collaboration with a commercial cast company who has a capability of vacuum induction melting. A 39lb columnar ingot with ~81mm diameter and ~305mm height (with hot-top) was commercially cast, homogenized, hot-extruded, and annealed providing 10mm-diameter bar-shape samples with the fine sub-grain structure. This commercial heat proved consistent with materials produced at ORNL at the lab-scale. Tubes and end caps were machined from the bar sample and provided to another work package for the ATF-1 irradiation campaign in the milestone M3FT-14OR0202251.« less
Bright x-ray stainless steel K-shell source development at the National Ignition Facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
May, M. J.; Fournier, K. B.; Colvin, J. D.
2015-06-15
High x-ray conversion efficiency (XRCE) K-shell sources are being developed for high energy density experiments for use as backlighters and for the testing of materials exposed to high x-ray fluxes and fluences. Recently, sources with high XRCE in the K-shell x-ray energy range of iron and nickel were investigated at the National Ignition Facility (NIF). The x-ray conversion efficiency in the 5–9 keV spectral range was determined to be 6.8% ± 0.3%. These targets were 4.1 mm diameter, 4 mm tall hollow epoxy tubes having a 50 μm thick wall supporting a tube of 3 to 3.5 μm thick stainless steel. The NIF laser deposited ∼460 kJ ofmore » 3ω light into the target in a 140 TW, 3.3 ns square pulse. The absolute x-ray emission of the source was measured by two calibrated Dante x-ray spectrometers. Time resolved images filtered for the Fe K-shell were recorded to follow the heating of the target. Time integrated high-resolution spectra were recorded in the K-shell range.« less
Development of a compact cryocooler system for high temperature superconductor filter application
NASA Astrophysics Data System (ADS)
Pang, Xiaomin; Wang, Xiaotao; Zhu, Jian; Chen, Shuai; Hu, Jianying; Dai, Wei; Li, Haibing; Luo, Ercang
2016-12-01
Seeking a higher specific power of the pulse tube cryocooler is an important trend in recent studies. High frequency operation (100 Hz and higher), combined with co-axial configuration, serve as a good option to meet this requirement. This paper introduces a high efficiency co-axial pulse tube cryocooler operating at around 100 Hz. The whole system weighs 4.3 kg (not including the radiator) with a nominal input power of 320 W, namely, power density of the system is around 74 W/kg. The envelop dimensions of the cold finger itself is about 84 mm in length and 23 mm in outer diameter. Firstly, numerical model for designing the system and some simulation results are briefly introduced. Distributions of pressure wave, the phase difference between the pressure wave and the volume flow rate and different energy flow are presented for a better understanding of the system. After this, some of the characterizing experimental results are presented. At an optimum working point, the cooling power at 80 K reaches 16 W with an input electric power of 300 W, which leads to an efficiency of 15.5% of Carnot.
Bright x-ray stainless steel K-shell source development at the National Ignition Facility
May, M. J.; Fournier, K. B.; Colvin, J. D.; ...
2015-06-01
High x-ray conversion efficiency (XRCE) K-shell sources are being developed for high energy density experiments for use as backlighters and for the testing of materials exposed to high x-ray fluxes and fluences. Recently, sources with high XRCE in the K-shell x-ray energy range of iron and nickel were investigated at the National Ignition Facility (NIF). The x-ray conversion efficiency in the 5–9 keV spectral range was determined to be 6.8% ± 0.3%. These targets were 4.1 mm diameter, 4 mm tall hollow epoxy tubes having a 50 μm thick wall supporting a tube of 3 to 3.5 μm thick stainlessmore » steel. The NIF laser deposited ~460 kJ of 3ω light into the target in a 140 TW, 3.3 ns square pulse. The absolute x-ray emission of the source was measured by two calibrated Dante x-ray spectrometers. In conclusion, time resolved images filtered for the Fe K-shell were recorded to follow the heating of the target. Time integrated high-resolution spectra were recorded in the K-shell range« less
Bright x-ray stainless steel K-shell source development at the National Ignition Facility
NASA Astrophysics Data System (ADS)
May, M. J.; Fournier, K. B.; Colvin, J. D.; Barrios, M. A.; Dewald, E. L.; Hohenberger, M.; Moody, J.; Patterson, J. R.; Schneider, M.; Widmann, K.; Regan, S. P.
2015-06-01
High x-ray conversion efficiency (XRCE) K-shell sources are being developed for high energy density experiments for use as backlighters and for the testing of materials exposed to high x-ray fluxes and fluences. Recently, sources with high XRCE in the K-shell x-ray energy range of iron and nickel were investigated at the National Ignition Facility (NIF). The x-ray conversion efficiency in the 5-9 keV spectral range was determined to be 6.8% ± 0.3%. These targets were 4.1 mm diameter, 4 mm tall hollow epoxy tubes having a 50 μm thick wall supporting a tube of 3 to 3.5 μm thick stainless steel. The NIF laser deposited ˜460 kJ of 3ω light into the target in a 140 TW, 3.3 ns square pulse. The absolute x-ray emission of the source was measured by two calibrated Dante x-ray spectrometers. Time resolved images filtered for the Fe K-shell were recorded to follow the heating of the target. Time integrated high-resolution spectra were recorded in the K-shell range.
Duan, Nan-Qi; Yan, Dong; Chi, Bo; Pu, Jian; Jian, Li
2015-01-01
Tubular solid oxide fuel cells were fabricated and evaluated for their microstructure and electrochemical performance. The tubular substrate was prepared by casting NiO-Y2O3 stabilized ZrO2 (YSZ) slurry on the inner wall of a plastic mold (tube). The wall thickness and uniformity were controlled by slurry viscosity and rotation speed of the tube. The cells consisted of Ni-YSZ functional anode, YSZ electrolyte and (La0.8Sr0.2)0.95MnO3-δ (LSM)-YSZ cathode prepared in sequence on the substrate by dip-coating and sintering. Their dimension was 50 mm in length, 0.8 mm in thickness and 10.5 mm in outside diameter. The peak power density of the cell at temperatures between 650 and 850°C was in the range from 85 to 522 mW cm−2 and was greatly enhanced to the range from 308 to 1220 mW cm−2 by impregnating PdO into LSM-YSZ cathode. During a cell testing at 0.7 A cm−2 and 750°C for 282 h, the impregnated PdO particles grew by coalescence, which increased the cathode polarization resistance and so that decreased the cell performance. According to the degradation tendency, the cell performance will be stabilized in a longer run. PMID:25640168
Laser-Ultrasonic Testing and its Applications to Nuclear Reactor Internals
NASA Astrophysics Data System (ADS)
Ochiai, M.; Miura, T.; Yamamoto, S.
2008-02-01
A new nondestructive testing technique for surface-breaking microcracks in nuclear reactor components based on laser-ultrasonics is developed. Surface acoustic wave generated by Q-switched Nd:YAG laser and detected by frequency-stabilized long pulse laser coupled with confocal Fabry-Perot interferometer is used to detect and size the cracks. A frequency-domain signal processing is developed to realize accurate sizing capability. The laser-ultrasonic testing allows the detection of surface-breaking microcrack having a depth of less than 0.1 mm, and the measurement of their depth with an accuracy of 0.2 mm when the depth exceeds 0.5 mm including stress corrosion cracking. The laser-ultrasonic testing system combined with laser peening system, which is another laser-based maintenance technology to improve surface stress, for inner surface of small diameter tube is developed. The generation laser in the laser-ultrasonic testing system can be identical to the laser source of the laser peening. As an example operation of the system, the system firstly works as the laser-ultrasonic testing mode and tests the inner surface of the tube. If no cracks are detected, the system then changes its work mode to the laser peening and improves surface stress to prevent crack initiation. The first nuclear industrial application of the laser-ultrasonic testing system combined with the laser peening was completed in Japanese nuclear power plant in December 2004.
Harris, William G.
1985-01-01
A heat limiting tubular sleeve extending over only a portion of a tube having a generally uniform outside diameter, the sleeve being open on both ends, having one end thereof larger in diameter than the other end thereof and having a wall thickness which decreases in the same direction as the diameter of the sleeve decreases so that the heat transfer through the sleeve and tube is less adjacent the large diameter end of the sleeve than adjacent the other end thereof.
Uchiyama, Akinori; Yoshida, Takeshi; Yamanaka, Hidenori; Fujino, Yuji
2013-07-01
The resistance of the endotracheal tube (ETT), the heat and moisture exchanger (HME), and the ventilator may affect the patient's respiratory status. Although previous studies examined the inspiratory work of breathing (WOB), investigation of WOB in the expiratory phase is rare. We estimated tracheal pressure at the tip of the ETT (Ptrach) and calculated expiratory WOB imposed by the ETT, the HME, and the expiratory valve. We examined imposed expiratory WOB in patients under a continuous mandatory ventilation (CMV) mode and during spontaneous breathing trials (SBTs). We hypothesized that imposed expiratory WOB would increase with heightened ventilatory demand. We measured airway pressure (Paw) and respiratory flow (V). We estimated Ptrach using the equation Ptrach = Paw - K1 × V(K2) - 2.70 × V(L/s)(1.42). K1 and K2 were determined by the inner diameter (ID) of the ETT. Imposed expiratory WOB was calculated from the area of Ptrach above PEEP versus lung volume. We examined imposed expiratory WOB and imposed expiratory resistance in relation to mean expiratory flow. We examined 28 patients under CMV mode, and 29 during SBT. During both CMV and SBT, as mean expiratory flow increased, imposed expiratory WOB increased. The regression curves between mean expiratory flow (x) (L/s) and imposed expiratory WOB (y) (J/L) were y = 1.35x(0.83) (R(2) = 0.79) for 7 mm ID ETT under CMV, y = 1.12x(0.82) (R(2) = 0.73) for 8 mm ID ETT under CMV, y = 1.07x(1.04) (R(2) = 0.85) for 7 mm ID ETT during SBT, and y = 0.84x(0.93) (R(2) = 0.75) for 8 mm ID ETT during SBT. Levels of imposed expiratory WOB were affected by ETT diameter and ventilator mode. The reason for increasing imposed expiratory WOB was an increase in expiratory resistance imposed by the ETT and HME. Under mechanical ventilation, imposed expiratory WOB should be considered in patients with higher minute ventilation.
A novel reciprocating micropump based on Lorentz force
NASA Astrophysics Data System (ADS)
Salari, Alinaghi; Hakimsima, Abbas; Shafii, Mohammad Behshad
2015-03-01
Lorentz force is the pumping basis of many electromagnetic micropumps used in lab-on-a-chip. In this paper a novel reciprocating single-chamber micropump is proposed, in which the actuation technique is based on Lorentz force acting on an array of microwires attached on a membrane surface. An alternating current is applied through the microwires in the presence of a magnetic field. The resultant force causes the membrane to oscillate and pushes the fluid to flow through microchannel using a ball-valve. The pump chamber (3 mm depth) was fabricated on a Polymethylmethacrylate (PMMA) substrate using laser engraving technique. The chamber was covered by a 60 μm thick hyper-elastic latex rubber diaphragm. Two miniature permanent magnets capable of providing magnetic field of 0.09 T at the center of the diaphragm were mounted on each side of the chamber. Square wave electric current with low-frequencies was generated using a function generator. Cylindrical copper microwires (250 μm diameter and 5 mm length) were attached side-by-side on top surface of the diaphragm. Thin loosely attached wires were used as connectors to energize the electrodes. Due to large displacement length of the diaphragm (~3 mm) a high efficiency (~90%) ball valve (2 mm diameter stainless steel ball in a tapered tubing structure) was used in the pump outlet. The micropump exhibits a flow rate as high as 490 μl/s and pressure up to 1.5 kPa showing that the pump is categorized among high-flow-rate mechanical micropumps.
Tooth movements in foxhounds after one or two alveolar corticotomies.
Sanjideh, Payam A; Rossouw, P Emile; Campbell, Phillip M; Opperman, Lynne A; Buschang, Peter H
2010-02-01
The aim of this split-mouth experimental study was to determine (1) whether corticotomy procedures increase tooth movement and (2) the effects of a second corticotomy procedure after 4 weeks on the rate of tooth movement. The mandibular third and maxillary second premolars of five skeletally mature male foxhounds, approximately 2 years of age, were extracted. One randomly selected mandibular quadrant had buccal and lingual flaps and corticotomies performed around the second premolar; the other quadrant served as the control. Both maxillary quadrants had initial buccal flaps and corticotomies; one randomly selected quadrant had a second buccal flap surgery and corticotomy after 28 days. Coil springs (200 g force), along with a 0.045 mm diameter tube on a 0.040 mm diameter guiding wire, were used to move the mandibular second and maxillary third premolars. Records, including digital calliper measurements and radiographs, were taken on days 0, 10, 14, 28, 42, and 56. Multilevel statistical procedures were used to model longitudinal tooth movements. The radiographic measurements initially showed increasing mandibular tooth movement rates, peaking between 22 and 25 days, and then decelerating. Total mandibular tooth movements were significantly (P < 0.05) greater on the experimental (2.4 mm) than on the control (1.3 mm) side. The rates of maxillary tooth movement slowed over time, with significantly (P < 0.05) more overall tooth movement on the side that had two (2.3 mm) than one (2.0 mm) corticotomy procedure. Alveolar corticotomy significantly increases orthodontic tooth movement. Performing a second corticotomy procedure after 4 weeks maintained higher rates of tooth movement over a longer duration and produced greater overall tooth movement than performing just one initial corticotomy, but the difference was small.
Extrusion of metal oxide superconducting wire, tube or ribbon
Dusek, Joseph T.
1993-10-05
A process for extruding a superconducting metal oxide composition YBa.sub.2 Cu.sub.3 O.sub.7-x provides a wire (tube or ribbon) having a cohesive mass and a degree of flexibility together with enhanced electrical properties. Wire diameters in the range of 6-85 mils have been produced with smaller wires on the order of 10 mils in diameter exhibiting enhanced flexibility for forming braided, or multistrand, configurations for greater current carrying capacity. The composition for extrusion contains a polymeric binder to provide a cohesive mass to bind the particles together during the extrusion process with the binder subsequently removed at lower temperatures during sintering. The composition for extrusion further includes a deflocculent, an organic plasticizer and a solvent which also are subsequently removed during sintering. Electrically conductive tubing with an inner diameter of 52 mil and an outer diameter of 87-355 mil has also been produced. Flat ribbons have been produced in the range of 10-125 mil thick by 100-500 mil wide. The superconducting wire, tube or ribbon may include an outer ceramic insulating sheath co-extruded with the wire, tubing or ribbon.
Extrusion of metal oxide superconducting wire, tube or ribbon
Dusek, Joseph T.
1993-01-01
A process for extruding a superconducting metal oxide composition YBa.sub.2 Cu.sub.3 O.sub.7-x provides a wire (tube or ribbon) having a cohesive mass and a degree of flexibility together with enhanced electrical properties. Wire diameters in the range of 6-85 mils have been produced with smaller wires on the order of 10 mils in diameter exhibiting enhanced flexibility for forming braided, or multistrand, configurations for greater current carrying capacity. The composition for extrusion contains a polymeric binder to provide a cohesive mass to bind the particles together during the extrusion process with the binder subsequently removed at lower temperatures during sintering. The composition for extrusion further includes a deflocculent, an organic plasticizer and a solvent which also are subsequently removed during sintering. Electrically conductive tubing with an inner diameter of 52 mil and an outer diameter of 87-355 mil has also been produced. Flat ribbons have been produced in the range of 10-125 mil thick by 100-500 mil wide. The superconducting wire, tube or ribbon may include an outer ceramic insulating sheath co-extruded with the wire, tubing or ribbon.
Copper bromide vapour laser with an output pulse duration of up to 320 ns
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gubarev, F A; Fedorov, K V; Evtushenko, G S
We report the development of a copper bromide vapour laser with an output pulse duration of up to 320 ns. To lengthen the pulse, the discharge current was limited using a compound switch comprising a pulsed hydrogen thyratron and a tacitron. This technique permits limiting the excitation of the working levels at the initial stage of the discharge development to lengthen the inversion lifetime. The longest duration of a laser pulse was reached in tubes 25 and 50 mm in diameter for a pulse repetition rate of 2 – 4 kHz. (lasers and laser beams)
1983-06-01
selected from the pump calibration curve to give the desired discharge rate. The valve to the hol-ing tank was then opened. The rotational rate of the r...immiscible and insoluble. To spill the chemical, a remote valve was used to activate the pneumatic cylinder and raise the spill tank in less than one second...which included 6.4 mm (0.25 inch) diameter stainless steel tubing, fittings, ball valves , 19 liter (5 gal) reservoir, and sight gage. During an
Propagation of detonation wave in hydrogen-air mixture in channels with sound-absorbing surfaces
NASA Astrophysics Data System (ADS)
Bivol, G. Yu.; Golovastov, S. V.; Golub, V. V.
2015-12-01
The possibility of using sound-absorbing surfaces for attenuating the intensity of detonation waves propagating in hydrogen-air mixtures has been experimentally studied in a cylindrical detonation tube open at one end, with an explosive initiated by spark discharge at the closed end. Sound-absorbing elements were made of an acoustic-grade foamed rubber with density of 0.035 g/cm3 containing open pores with an average diameter of 0.5 mm. The degree of attenuation of the detonation wave front velocity was determined as dependent on the volume fraction of hydrogen in the gas mixture.
Devices to protect seedlings from deer browsing
David A. Marquis
1977-01-01
Studies on the Allegheny Plateau of Pennsylvania have shown that several types of wire or plastic tubes can be erected around tree seedlings to protect them from deer browsing. The two most promising devices are a 4- to 6-inch diameter plastic tube with small mesh and a 12-inch diameter tube constructed of chicken wire. Both types need to be at least 5 feet tall to...
Origin of Granular Capillarity Revealed by Particle-Based Simulations
NASA Astrophysics Data System (ADS)
Fan, Fengxian; Parteli, Eric J. R.; Pöschel, Thorsten
2017-05-01
When a thin tube is dipped into water, the water will ascend to a certain height, against the action of gravity. While this effect, termed capillarity, is well known, recent experiments have shown that agitated granular matter reveals a similar behavior. Namely, when a vertical tube is inserted into a container filled with granular material and is then set into vertical vibration, the particles rise up along the tube. In the present Letter, we investigate the effect of granular capillarity by means of numerical simulations and show that the effect is caused by convection of the granular material in the container. Moreover, we identify two regimes of behavior for the capillary height Hc∞ depending on the tube-to-particle-diameter ratio, D /d . For large D /d , a scaling of Hc∞ with the inverse of the tube diameter, which is reminiscent of liquids, is observed. However, when D /d decreases down to values smaller than a few particle sizes, a uniquely granular behavior is observed where Hc∞ increases linearly with the tube diameter.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sohbatzadeh, Farshad, E-mail: f.sohbat@umz.ac.ir; Nano and Biotechnology Research Group, Faculty of Basic Sciences, University of Mazandaran, Babolsar 47416-95447, Mazandaran; Omran, Azadeh Valinataj
2014-11-15
In this work, we developed transporting atmospheric pressure cold plasma using single electrode configuration through a sub-millimetre flexible dielectric tube beyond 100 cm. It was shown that the waveform of the applied high voltage is essential for controlling upstream and downstream plasma inside the tube. In this regard, sawtooth waveform enabled the transport of plasma with less applied high voltage compared to sinusoidal and pulsed form voltages. A cold plasma string as long as 130 cm was obtained by only 4 kV peak-to-peak sawtooth high voltage waveform. Optical emission spectroscopy revealed that reactive chemical species, such as atomic oxygen and hydroxyl, are generatedmore » at the tube exit. The effect of tube diameter on the transported plasma was also examined: the smaller the diameter, the higher the applied voltage. The device is likely to be used for sterilization, decontamination, and therapeutic endoscopy as already suggested by other groups in recent past years.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rozana, Monna; Soaid, Nurul Izza; Lockman, Zainovia, E-mail: zainovia@usm.my
ZrO{sub 2} nanotube arrays were formed by anodizing zirconium sheet in ethylene glycol (EG) and EG added to it KOH (EG/KOH) electrolytes. The effect of KOH addition into EG electrolyte to the morphology of nanotubes and their crystallinity was investigated. It was observed that the tubes with diameter of ∼80 nm were formed in EG electrolyte with <0.1 vol % water, but the wall smoothness is rather poor. When KOH was added into EG, the wall smoothness of the nanotubes improve, but the diameter of tubes is smaller (∼40 nm). Despite smoother wall and small tube diameter, the degradation ofmore » methyl orange (MO) on the tubes made in EG/KOH is less compared to the tubes made in EG only. This could be due to the less tetragonal ZrO{sub 2} presence in the tubes made in EG/KOH.« less
Small incision guarded hydroaspiration of iris lesions.
Singh, Arun D
2017-11-01
To describe the technique and results of a minimally invasive surgical technique for resection of small iris lesions. Consecutive case series of 22 patients with localised, small iris lesions that were resected using the described surgical technique that composed of multiple, small corneal incisions created to allow for internal iris resection with 23-gauge horizontal vitrectomy scissors, followed by guarded tumour aspiration through a clear plastic tubing (diameter 3.5 mm) primed with viscoelastic agent. The mean largest basal diameter was 3.0 mm (range 1.5-5.0 mm; median 3.0 mm) and mean thickness was 1.3 mm (range 0.5-2.5 mm; median 1.0 mm). Use of multiple (2-4) small corneal incisions (range 2.0-3.0 mm; mean 2.8 mm) allowed reduced postoperative morbidity (significant hyphema (0%), hypotony (0%), wound leak (0%), >2 line change in best corrected visual acuity at postoperative 1 week (4.5%) and mean corneal astigmatism of 1.0 D (range 0.14-2.99 D; median 0.8 D) at postoperative 4-12 weeks. The tumour could be resected with clear surgical margins in all neoplastic cases (benign (2), borderline (1) and malignant (16)). Local recurrence or metastases were not observed in any melanoma case over a mean follow-up of 33.0 months (range 1.0-90.0 months; median 33.5 months). Small incision guarded hydroaspiration is a minimally invasive surgical technique for resection of select small iris lesions. Use of multiple small corneal incisions avoids morbidity associated with a single large corneoscleral incision, and use of guarded aspiration may eliminate the risk of wound contamination by the malignant tumour. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Varghese, Oomman K; Mor, Gopal K; Grimes, Craig A; Paulose, Maggie; Mukherjee, Niloy
2004-09-01
A tremendous variation in electrical resistance, from the semiconductor to metallic range, has been observed in titania nanotube arrays at room temperature, approximately 25 degrees C, in the presence of < or = 1000 ppm hydrogen gas. The nanotube arrays are fabricated by anodizing titanium foil in an aqueous electrolyte solution containing hydrofluoric acid and acetic acid. Subsequently, the arrays are coated with a 10 nm layer of palladium by evaporation. Electrical contacts are made by sputtering a 2 mm diameter platinum disk atop the Pd-coated nanotube array. These sensors exhibit a resistance variation of the order of 10(4) in the presence of 100 ppm hydrogen at 25 degrees C. The sensors demonstrate complete reversibility, repeatability, high selectivity, negligible drift and wide dynamic range. The nanoscale geometry of the nanotubes, in particular the points of tube-to-tube contact, is believed to be responsible for the outstanding hydrogen gas sensitivities.
NASA Astrophysics Data System (ADS)
Novianto, S.; Pamitran, A. S.; Nasruddin, Alhamid, M. I.
2016-06-01
Due to its friendly effect on the environment, natural refrigerants could be the best alternative refrigerant to replace conventional refrigerants. The present study was devoted to the effect of superficial velocity on vaporization pressure drop with propane in a horizontal circular tube with an inner diameter of 7.6 mm. The experiments were conditioned with 4 to 10 °C for saturation temperature, 9 to 20 kW/m2 for heat flux, and 250 to 380 kg/m2s for mass flux. It is shown here that increased heat flux may result in increasing vapor superficial velocity, and then increasing pressure drop. The present experimental results were evaluated with some existing correlations of pressure drop. The best prediction was evaluated by Lockhart-Martinelli (1949) with MARD 25.7%. In order to observe the experimental flow pattern, the present results were also mapped on the Wang flow pattern map.
A surgical parallel continuum manipulator with a cable-driven grasper.
Orekhov, Andrew L; Bryson, Caroline E; Till, John; Chung, Scotty; Rucker, D Caleb
2015-01-01
In this paper, we present the design, construction, and control of a six-degree-of-freedom (DOF), 12 mm diameter, parallel continuum manipulator with a 2-DOF, cable-driven grasper. This work is a proof-of-concept first step towards miniaturization of this type of manipulator design to provide increased dexterity and stability in confined-space surgical applications, particularly for endoscopic procedures. Our robotic system consists of six superelastic NiTi (Nitinol) tubes in a standard Stewart-Gough configuration and an end effector with 180 degree motion of its two jaws. Two Kevlar cables pass through the centers of the tube legs to actuate the end effector. A computationally efficient inverse kinematics model provides low-level control inputs to ten independent linear actuators, which drive the Stewart-Gough platform and end-effector actuation cables. We demonstrate the performance and feasibility of this design by conducting open-loop range-of-motion tests for our system.
In vivo laser-based imaging of the human fallopian tube for future cancer detection
NASA Astrophysics Data System (ADS)
Seibel, Eric J.; Melville, C. David; Johnston, Richard S.; Gong, Yuanzheng; Agnew, Kathy; Chiang, Seine; Swisher, Elizabeth M.
2015-03-01
Inherited mutations in BRCA1 and BRCA2 lead to 20-50% lifetime risk of ovarian, tubal, or peritoneal carcinoma. Clinical recommendations for women with these genetic mutations include the prophylactic removal of ovaries and fallopian tubes by age 40 after child-bearing. Recent findings suggest that many presumed ovarian or peritoneal carcinomas arise in fallopian tube epithelium. Although survival rate is <90% when ovarian cancer is detected early (Stage_I), 70% of women have advanced disease (Stage_III/IV) at presentation when survival is less than 30%. Over the years, effective early detection of ovarian cancer has remained elusive, possibly because screening techniques have mistakenly focused on the ovary as origin of ovarian carcinoma. Unlike ovaries, the fallopian tubes are amenable to direct visual imaging without invasive surgery, using access through the cervix. To develop future screening protocols, we investigated using our 1.2- mm diameter, forward-viewing, scanning fiber endoscope (SFE) to image luminal surfaces of the fallopian tube before laparoscopic surgical removal. Three anesthetized human subjects participated in our protocol development which eventually led to 70-80% of the length of fallopian tubes being imaged in scanning reflectance, using red (632nm), green (532nm), and blue (442nm) laser light. A hysteroscope with saline uterine distention was used to locate the tubal ostia. To facilitate passage of the SFE through the interstitial portion of the fallopian tube, an introducer catheter was inserted 1- cm through each ostia. During insertion, saline was flushed to reduce friction and provide clearer viewing. This is likely the first high-resolution intraluminal visualization of fallopian tubes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asako, Y.; Nakamura, H.; Faghri, M.
1990-08-01
Natural convection is often a convenient and inexpensive mode of heat transfer. It is commonly employed in the cooling of electronic equipment and many other applications. Since the initial work by Bodoia and Osterle (1962) on finite difference solutions of natural convection between vertical isothermal plates, many other researchers have studied natural convection in vertical channels. Specifically Davis and Perona (1971) studied natural convection in vertical heated tubes. A thermally insulated chimney attached to a vertical heated channel induces an increase in the natural convection in the channel and leads to a higher heat transfer rate. This is the well-knownmore » chimney effect discussed in the paper by Haaland and Sparrow (1983). If the chimney diameter is larger than the heated tube diameter, the friction loss in the chimney region decreases with increasing chimney diameter. This induces an increase in the mass flow rate and leads to a higher heat transfer rate than the case for a chimney of the same diameter. However, from a geometric consideration it is evident that the chimney effect diminishes in the limiting case of an extremely large chimney diameter compared with its height. Therefore, there exists an optimum diameter where the heat transfer is maximum. To investigate the chimney effect computations are carried out for a Rayleigh number of 12.5, based on the heated tube radius, and for a Prandtl number of 0.7. The numerical results are based on a control volume finite difference method. The average Nusselt number results are compared with the numerical results obtained for a chimney attached to a tube of the same diameter.« less
NASA Astrophysics Data System (ADS)
McNulty, Thomas Francis
Piezoelectric tube composite hydrophones of 3-1, 3-2, and 2-2 connectivity were developed using Fused Deposition (FD) and lost mold processing (LMP). In this work, a new series of thermoplastic binder formulations, named the ECG series, were developed for the FD process. The ECG-9 formulation exhibits mechanical, thermal, and rheological properties suitable for the Fused Deposition of functional lead zirconate titanate ceramic devices. This binder consists of 100 parts (by weight) Vestoplast 408, 20 parts Escorez 2520, 15 parts Vestowax A-227, and 5 parts Indopol H-1500. Oleic acid, oleyl alcohol, stearic acid, and stearyl alcohol (in toluene) were tested for use as a dispersant in the PZT/ECG-9 system. It was found that stearic acid adsorbs the most onto PZT powder, adsorbing 8.1 mg/m2. Using stearic acid, solutions of increasing concentration (5.0--50.0 g/l) were measured for adsorption. It was found that 30.0 g/l is the minimum concentration necessary for optimum surface coverage. The surfactant-coated powder was compounded with ECG-9 binder to create a 54 vol.% mix. The mix was extruded using a single screw extrusion apparatus into continuous lengths (>30 m) of 1.78 mm diameter filament. Fused Deposition was used to create composite designs of 3-1, 3-2, and 2-2 connectivity. After sintering, samples exhibit a sintered density greater than 97%. Sanders Prototyping (SPI) was used to manufacture molds for use with LMP techniques. Molds of 3-1, 3-2, and 2-2 connectivity were developed. The molds were infiltrated with a 55 vol.% aqueous based PZT slurry. The parts were subjected to a binder decomposition cycle, followed by sintering. Resultant samples were highly variable due to random macro-pores present in the samples after sintering. The resultant preforms were embedded in epoxy, and polished to dimensions of 8.0 mm inside diameter (ID), 14.0 mm outside diameter (OD), and 10.0 mm length (l) the OD and l dimensions are accurate to +/--2%, while the ID is accurate to +/--5%. Samples were corona poled, and the electromechanical properties were evaluated. Dielectric constant (K), hydrostatic charge coefficients (dh), and radial displacements (ur) were measured. Of the seven composite types studied, the FD-based composites with 3-2 connectivity exhibited the highest average dh of 42.4 pCN. The same 3-2 composites exhibited the highest dhgh (FOM) of 140 fm2/N.
NASA Astrophysics Data System (ADS)
MacPhee, A. G.; Smalyuk, V. A.; Landen, O. L.; Weber, C. R.; Robey, H. F.; Alfonso, E. L.; Biener, J.; Bunn, T.; Crippen, J. W.; Farrell, M.; Felker, S.; Field, J. E.; Hsing, W. W.; Kong, C.; Milovich, J.; Moore, A.; Nikroo, A.; Rice, N.; Stadermann, M.; Wild, C.
2018-05-01
We report a reduced X-ray shadow imprint of hydrodynamic instabilities on the high-density carbon ablator surface of inertial confinement fusion (ICF) capsules using a reduced diameter fuel fill tube on the National Ignition Facility (NIF). The perturbation seed mass from hydrodynamic instabilities was reduced by approximately an order of magnitude by reducing both the diameter and wall thickness of the fill tube by ˜2×, consistent with analytical estimates. This work demonstrates a successful mitigation strategy for engineered features for ICF implosions on the NIF.
Geometry effects on cooling in a standing wave cylindrical thermoacousic resonator
NASA Astrophysics Data System (ADS)
Mohd-Ghazali, Normah; Ghazali, Ahmad Dairobi; Ali, Irwan Shah; Rahman, Muhammad Aminullah A.
2012-06-01
Numerous reports have established the refrigeration applications of thermoacoustic cooling without compressors and refrigerants. Significant cooling effects can be obtained in a thermoacoustic resonator fitted with a heat exchanging stack and operated at resonance frequency. Past studies, however, have hardly referred to the fundamental relationship between resonant frequency and the resonator geometry. This paper reports the thermoacoustic cooling effects at resonance obtained by changing the diameter of the resonator while holding the length constant and vice versa. Experiments were completed at atmospheric pressure with air as the working fluid using a number of pvc tubes having parallel plate stack from Mylar. The temperature difference measured across the stack showed that a volume increase in the working fluid in general increases the temperature gradient for the quarter-and half-wavelength resonators. Doubling the diameter from 30 mm to 60 mm produced the highest temperature difference due to the greater number of stack plates resulting in a higher overall thermoacaoustic cooling. Increasing the resonator length only produced a small increase in temperature gradient since the resonant frequency at operation is only slightly changed. Investigation on the aspect ratio exhibits no influence on the temperature difference across the stack. This study have shown that the resonator length and diameter do affect the temperature difference across the thermoacoustic stack, and further research should be done to consider the contribution of the stack mass on the overall desired thermoacoustic cooling.
NASA Astrophysics Data System (ADS)
de Blauwe, K.; Mowbray, D. J.; Miyata, Y.; Ayala, P.; Shiozawa, H.; Rubio, A.; Hoffmann, P.; Kataura, H.; Pichler, T.
2010-09-01
Narrow diameter tubes and especially (6,5) tubes with a diameter of 0.75 nm are currently one of the most studied carbon nanotubes because their unique optical and especially luminescence response makes them exceptionally suited for biomedical applications. Here we report on a detailed analysis of the electronic structure of nanotubes with (6,5) and (6,4) chiralities using a combined experimental and theoretical approach. From high-energy spectroscopy involving x-ray absorption and photoemission spectroscopy the detailed valence- and conduction-band response of these narrow diameter tubes is studied. The observed electronic structure is in sound agreement with state of the art ab initio calculations using density-functional theory.
Subcutaneous fluid port-associated soft tissue sarcoma in a cat.
McLeland, Shannon M; Imhoff, Darren J; Thomas, Michelle; Powers, Barb E; Quimby, Jessica M
2013-10-01
A 20-year-old male castrated domestic longhair cat was evaluated for assessment of its chronic kidney disease (CKD) and a non-healing ulcerated mass at the site of a previously placed and subsequently removed GIF tube. The cat had been diagnosed with CKD 10 years prior and two GIF tubes had been placed over a 5-year period, the second of which was associated with secondary infection. Biopsy of the non-healing ulcerated mass was consistent with grade 2 soft tissue sarcoma. At necropsy there was a discrete, serpentine, subcutaneous mass measuring approximately 8 mm in diameter that extended approximately 20 cm along the dorsum to the caudal thorax, following the path of the GIF tube, from the main intrascapular, ulcerated mass where the fluid port injection site was located. This is the first report of a fibrosarcoma arising at the site of a subcutaneous fluid port in a cat. Although the cat's owners were pleased with the 4 years of quality of life provided by this device, this complication should be considered when a decision to place ports for long-term management of disease is made.
Laboratory testing the Anaconda.
Chaplin, J R; Heller, V; Farley, F J M; Hearn, G E; Rainey, R C T
2012-01-28
Laboratory measurements of the performance of the Anaconda are presented, a wave energy converter comprising a submerged water-filled distensible tube aligned with the incident waves. Experiments were carried out at a scale of around 1:25 with a 250 mm diameter and 7 m long tube, constructed of rubber and fabric, terminating in a linear power take-off of adjustable impedance. The paper presents some basic theory that leads to predictions of distensibility and bulge wave speed in a pressurized compound rubber and fabric tube, including the effects of inelastic sectors in the circumference, longitudinal tension and the surrounding fluid. Results are shown to agree closely with measurements in still water. The theory is developed further to provide a model for the propagation of bulges and power conversion in the Anaconda. In the presence of external water waves, the theory identifies three distinct internal wave components and provides theoretical estimates of power capture. For the first time, these and other predictions of the behaviour of the Anaconda, a device unlike almost all other marine systems, are shown to be in remarkably close agreement with measurements.
A spectral radiance comparison of a noise tube and a HgXe arc lamp between 60 GHz and 600 GHz
NASA Technical Reports Server (NTRS)
Heaney, J. B.; Stewart, K. P.; Boucarut, R. A.; Moller, K. D.; Zoeller, R.
1987-01-01
The relative spectral radiance of a noise tube, model TN-167, designed for the frequency range 90-140 GHz (3.3 mm to 2.1 mm) was compared to that from a 200-watt high pressure HgXe arc lamp over the wavelength region from 0.5 to about 5 mm. A Michelson Fourier transform spectrometer and a lamellar grating instrument were used in conjunction with liquid helium-cooled bolometers of NEP 10 to the -12th to 10 to the -14th watt/(Hz) exp 1/2 to measure relative spectral radiant power. With this instrumental arrangement, the noise tube exhibited a very sharp low frequency cutoff at about 2.2/cm. The HgXe arc lamp emitted more radiant power than the noise tube in the wavelength region below 3 mm (100 GHz) down to 0.5 mm. Above 3 mm, the noise tube had a stronger output. The noise tube spectral radiance shifted to lower frequencies when the input current was lowered from 125 mA to 50 mA.
Hydraulic Testing of Polymer Matrix Composite 102mm Tube Section Technical Report
2018-04-01
Technical Report ARWSB-TR-18025 Hydraulic Testing of Polymer Matrix Composite 102mm Tube Section Technical Report Lucas B...1. REPORT DATE (DD-MM-YYYY) April 2018 2. REPORT TYPE Technical 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Hydraulic Testing of...Polymer Matrix Composite 102mm Tube Section Technical Report 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER
Effect of Probe Tube Insertion Depth on Spectral Measures of Speech
Caldwell, Marc; Souza, Pamela E.; Tremblay, Kelly L.
2006-01-01
This study investigated how depth variations in the tip of the probe tube affected spectral measures of speech recorded in the external ear canal. Consonant-vowel nonsense syllables were recorded with a probe tube microphone system in 10 adult participants with normal middle ear function. Recordings were made with the probe tube tip placed 1 mm, 5 mm, and 10 mm beyond the medial tip of a custom earmold. The effect of probe depth was evaluated on spectral levels (one-third octave and one-twelfth octave band). Extending the probe tube 10 mm past the medial tip of the earmold gave the most accurate results, with relatively lower sound levels for either the 1-mm or 5-mm insertion depth. In general, the effect of insertion depth was minimal at frequencies below 3 to 4 kHz, although this varied with the specific phoneme and the width of the analysis bands. The authors found no significant difference between 1- and 5-mm insertion depths, suggesting that as long as the tip of the probe tube is sufficiently close to the tympanic membrane to capture the highest frequency of interest, it makes little difference if it is less than 5 mm beyond the earmold tip. PMID:16959735
Detonation mode and frequency analysis under high loss conditions for stoichiometric propane-oxygen
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jackson, Scott I.; Lee, Bok Jik; Shepherd, Joseph E.
In this paper, the propagation characteristics of galloping detonations were quantified with a high-time-resolution velocity diagnostic. Combustion waves were initiated in 30-m lengths of 4.1-mm inner diameter transparent tubing filled with stoichiometric propane–oxygen mixtures. Chemiluminescence from the resulting waves was imaged to determine the luminous wave front position and velocity every 83.3 μ. As the mixture initial pressure was decreased from 20 to 7 kPa, the wave was observed to become increasingly unsteady and transition from steady detonation to a galloping detonation. While wave velocities averaged over the full tube length smoothly decreased with initial pressure down to half ofmore » the Chapman–Jouguet detonation velocity (D CJ) at the quenching limit, the actual propagation mechanism was seen to be a galloping wave with a cycle period of approximately 1.0 ms, corresponding to a cycle length of 1.3–2.0 m or 317–488 tube diameters depending on the average wave speed. The long test section length of 7300 tube diameters allowed observation of up to 20 galloping cycles, allowing for statistical analysis of the wave dynamics. In the galloping regime, a bimodal velocity distribution was observed with peaks centered near 0.4 D CJ and 0.95 D CJ. Decreasing initial pressure increasingly favored the low velocity mode. Galloping frequencies ranged from 0.8 to 1.0 kHz and were insensitive to initial mixture pressure. Wave deflagration-to-detonation transition and detonation failure trajectories were found to be repeatable in a given test and also across different initial mixture pressures. The temporal duration of wave dwell at the low and high velocity modes during galloping was also quantified. It was found that the mean wave dwell duration in the low velocity mode was a weak function of initial mixture pressure, while the mean dwell time in the high velocity mode depended exponentially on initial mixture pressure. Analysis of the velocity histories using dynamical systems ideas demonstrated trajectories that varied from stable to limit cycles to aperiodic motion with decreasing initial pressure. Finally, the results indicate that galloping detonation is a persistent phenomenon at long tube lengths.« less
Detonation mode and frequency analysis under high loss conditions for stoichiometric propane-oxygen
Jackson, Scott I.; Lee, Bok Jik; Shepherd, Joseph E.
2016-03-24
In this paper, the propagation characteristics of galloping detonations were quantified with a high-time-resolution velocity diagnostic. Combustion waves were initiated in 30-m lengths of 4.1-mm inner diameter transparent tubing filled with stoichiometric propane–oxygen mixtures. Chemiluminescence from the resulting waves was imaged to determine the luminous wave front position and velocity every 83.3 μ. As the mixture initial pressure was decreased from 20 to 7 kPa, the wave was observed to become increasingly unsteady and transition from steady detonation to a galloping detonation. While wave velocities averaged over the full tube length smoothly decreased with initial pressure down to half ofmore » the Chapman–Jouguet detonation velocity (D CJ) at the quenching limit, the actual propagation mechanism was seen to be a galloping wave with a cycle period of approximately 1.0 ms, corresponding to a cycle length of 1.3–2.0 m or 317–488 tube diameters depending on the average wave speed. The long test section length of 7300 tube diameters allowed observation of up to 20 galloping cycles, allowing for statistical analysis of the wave dynamics. In the galloping regime, a bimodal velocity distribution was observed with peaks centered near 0.4 D CJ and 0.95 D CJ. Decreasing initial pressure increasingly favored the low velocity mode. Galloping frequencies ranged from 0.8 to 1.0 kHz and were insensitive to initial mixture pressure. Wave deflagration-to-detonation transition and detonation failure trajectories were found to be repeatable in a given test and also across different initial mixture pressures. The temporal duration of wave dwell at the low and high velocity modes during galloping was also quantified. It was found that the mean wave dwell duration in the low velocity mode was a weak function of initial mixture pressure, while the mean dwell time in the high velocity mode depended exponentially on initial mixture pressure. Analysis of the velocity histories using dynamical systems ideas demonstrated trajectories that varied from stable to limit cycles to aperiodic motion with decreasing initial pressure. Finally, the results indicate that galloping detonation is a persistent phenomenon at long tube lengths.« less
Breckenridge, R Reid; Bartholomew, Luanna R; Crosson, Craig E; Kent, Alexander R
2004-10-01
To determine outflow resistance of the Baerveldt glaucoma implant using different tube configurations. Outflow resistance of 6 tube configurations (C1- C6) of Baerveldt implants was measured under conditions of constant pressure perfusion. Pressures ranged from 2 to 55 mm Hg. Venting slits were created using a 7-0 Vicryl, spatulated suture-needle. Seton tubes were occluded by threading a retrograde suture approximately 1.5 cm into the lumen. At pressures between 2 and 55 mm Hg, mean outflow resistance of the normally configured seton (ie, open tube; C1) was 0.41 (+/- 0.6) mm Hg/microL/min. Resistance was unchanged (mean 0.41 (+/- 0.4) mm Hg/microL/min) by the addition of 4 venting slits (C2) to the seton tube. Occlusion of the open seton tube with a 3-0 Supramid suture (C3) significantly increased (P < 0.001) mean outflow resistance to 14.99 (+/- 0.6) mm Hg/microL/min. Occlusion of the tube with a 4-0 Supramid suture (C4) significantly increased (P < 0.001) mean outflow resistance to 1.09 (+/- 0.5) mm Hg/microL/min. In implants where tubes were occluded with a 3-0 Supramid suture, the addition of venting slits (C5) significantly decreased (P = 0.038) mean outflow resistance to 8.98 (+/- 0.4) mm Hg/microL/min. In tubes occluded with a 4-0 Supramid suture, the addition of venting slits (C6) decreased mean outflow resistance to 0.98 (+/- 0.6) mm Hg/microL/min. Although these results cannot be directly correlated to the clinical setting, they do show that outflow resistance can be modified at the time of surgery by changing tube configuration of the Baerveldt glaucoma implant. Configuration C5 (3-0 Supramid with venting slits) closely approximates the outflow rate in the normal intraocular pressure range.
Risk factors for proximal migration of biliary tube stents
Kawaguchi, Yoshiaki; Ogawa, Masami; Kawashima, Yohei; Mizukami, Hajime; Maruno, Atsuko; Ito, Hiroyuki; Mine, Tetsuya
2014-01-01
AIM: To analyze the risk factors for biliary stent migration in patients with benign and malignant strictures. METHODS: Endoscopic stent placement was performed in 396 patients with bile duct stenosis, at our institution, between June 2003 and March 2009. The indications for bile duct stent implantation included common bile duct stone in 190 patients, malignant lesions in 112, chronic pancreatitis in 62, autoimmune pancreatitis in 14, trauma in eight, surgical complications in six, and primary sclerosing cholangitis (PSC) in four. We retrospectively examined the frequency of stent migration, and analyzed the patient factors (disease, whether endoscopic sphincterotomy was performed, location of bile duct stenosis and diameter of the bile duct) and stent characteristics (duration of stent placement, stent type, diameter and length). Moreover, we investigated retrieval methods for migrated stents and their associated success rates. RESULTS: The frequency of tube stent migration in the total patient population was 3.5%. The cases in which tube stent migration occurred included those with common bile duct stones (3/190; 1.6%), malignant lesions (2/112; 1.8%), chronic pancreatitis (4/62; 6.5%), autoimmune pancreatitis (2/14; 14.3%), trauma (1/8; 12.5%), surgical complications (2/6; 33.3%), and PSC (0/4; 0%). The potential risk factors for migration included bile duct stenosis secondary to benign disease such as chronic pancreatitis and autoimmune pancreatitis (P = 0.030); stenosis of the lower bile duct (P = 0.031); bile duct diameter > 10 mm (P = 0.023); duration of stent placement > 1 mo (P = 0.007); use of straight-type stents (P < 0.001); and 10-Fr sized stents (P < 0.001). Retrieval of the migrated stents was successful in all cases. The grasping technique, using a basket or snare, was effective for pig-tailed or thin and straight stents, whereas the guidewire cannulation technique was effective for thick and straight stents. CONCLUSION: Migration of tube stents within the bile duct is rare but possible, and it is important to determine the risk factors involved in stent migration. PMID:24574806
Study of a DC gas discharge with a copper cathode in a water flow
NASA Astrophysics Data System (ADS)
Tazmeev, G. Kh.; Timerkaev, B. A.; Tazmeev, Kh. K.
2017-07-01
A dc gas discharge between copper electrodes in the current range of 5-20 A was studied experimentally. The discharge gap length was varied within 45-70 mm. The cathode was a 10-mm-diameter rod placed in the water flowing out from a dielectric tube. Three discharge configurations differing in the position of the cathode upper end with respect to the water surface were considered: (i) above water; (ii) flush with the water surface, and (iii) under water. The electric and optical characteristics of the discharge in the second configuration were studied in more detail. It is established that the discharge properties are similar to those of an electric arc. Considerable cathode erosion was observed in the third configuration. It is revealed that fine-dispersed copper grains form in the course of erosion.
Flexible waveguides for IR laser radiation and surgery applications.
Gannot, I; Dror, J; Calderon, S; Kaplan, I; Croitoru, N
1994-01-01
Flexible plastic waveguides were developed to deliver IR radiation, especially at 10.6 microns, which is the CO2 laser radiation wavelength. The waveguide is made from teflon tube with the inner wall coated with a metal layer and a dielectric overlayer. The internal diameter (ID) is 1.0 mm, length 1.0-1.2 m, and the distal tip decreases moderately to ID approximately 0.6 mm. The distal part on the last 10 centimeters is coated externally with a metal layer. Maximum power that can be delivered at the outlet is approximately 30 W and 10.6 x 10(3) W/cm2. This type of waveguide was used in several medical operations to evaluate its cutting characteristics and the resistances to heat reflection from the tissue while operating in orifices containing liquid substances.
Hill, S. L.; Holt, D. W.
2007-01-01
Abstract: There has been much advancement in perfusion technology over its 50 years of progression. One of these techniques is vacuum-assisted venous drainage (VAVD). Many perfusionists augment venous drainage using VAVD, typically from a wall vacuum source. This study explores alternates to providing VAVD if the wall vacuum fails. In two porcine laboratories, ∼36 in. of 3/16-in. tubing was connected to a sucker return port and placed into the roller head next to the arterial pump. The vacuum was monitored with a DLP pressure monitoring system (Medtronic). This system was connected to small-bore tubing and attached to a stopcock on top of the reservoir. The vacuum was regulated using another stopcock connected to a non-filtered luer lock port on top of the reservoir or by a segment of 3 × 0.25-in.-diameter tubing attached to the vent port with a c-clamp. Vacuum drainage was achieved, ranging from −18 mmHg to −71 mmHg by manipulating the stopcock or c-clamp. Changes in venous drainage were seen by volume fluctuations in the venous reservoir. The vacuum was adjusted to account for dramatic changes. Augmented venous drainage using a roller pump can be achieved successfully during cardiopulmonary bypass (CPB). This method of active drainage can be used in lieu of wall suction or during times of emergency if wall suction fails. PMID:18293812
Nishimura, Junya; Kubo, Naoshi; Lee, Tomohiro; Shinto, Osamu; Sakurai, Katsunobu; Toyokawa, Takahiro; Tanaka, Hiroaki; Muguruma, Kazuya; Shibutani, Masatsune; Yamazoe, Sadaaki; Nagahara, Hisashi; Kimura, Kenjiro; Amano, Ryosuke; Ohtani, Hiroshi; Yashiro, Masakazu; Maeda, Kiyoshi; Ohira, Masaichi; Hirakawa, Kosei
2013-11-01
The patient was a 68-year-old man who complained of hoarseness and dyspnea. Upper gastrointestinal endoscopy revealed a type 3 tumor located in the middle thoracic esophagus at 30 cm from the incisor tooth that involved one-fourth of the circumference of the esophagus. Histopathological examination revealed moderately differentiated squamous cell carcinoma. Chest computed tomography( CT) revealed severe tracheal stenosis due to compression by a metastatic lymph node along the left recurrent laryngeal nerve. The patient was diagnosed as having cT4( 106recL-trachea), N2( 101L, 106recL, 106recR), M0, Stage IVa unresectable esophageal carcinoma. After insertion of a tracheal stent tube( spiral Z stent: diameter, 18 mm; length, 80 mm) to improve dyspnea, combination chemotherapy with 5-fluorouracil( 5-FU) plus nedaplatin was administered. Subsequent CT and endoscopy showed that the main tumor and the metastatic lymph node had significantly reduced in size and that complete response (CR) had been achieved. Thirty months after the initial treatment, the patient showed no sign of disease recurrence, after completion of 19 cycles of chemotherapy. The patient did not experience any severe adverse events. We report a case of a patient with locally advanced squamous cell carcinoma of the esophagus successfully treated with 5-FU/nedaplatin combination chemotherapy following tracheal stent tube placement.
Hwang, Da Young; Suh, Dong Hack
2014-06-07
Unlike nanoscrolls of 2D graphene, those of 2D h-BN have not been demonstrated, except for only a few experimental reports. Nanoscrolls of h-BN with high yields and reproducibility are first synthesized by a simple solution process. Inner-tube diameters of BNSs including LCAs, N-(2-aminoethyl)-3α-hydroxy-5β-cholan-24-amide, a bile acid derivative and self-assembling material, can be controlled by adjusting the diameter of the LCA fiber which is grown by self-assembly. TEM and SEM images show that BNSs have a tube-like morphology and the inner-tube diameter of BNSs can be controlled in the range from 20 to 60 nm for a smaller diameter, up to 300 nm for a larger diameter by LCA fiber growth inside the BNSs. Finally, open cylindrical BNSs with hollow cores were obtained by dissolving LCAs inside BNSs.
Meso and Micro Scale Propulsion Concepts for Small Spacecraft
2005-06-14
the inner diameter of the fuel jet tube was 500 gm, while the inner diameter of the air jet tube was 760 pim. Figure 2. Meso-scale whirl combustion of...decomposition. This mechanism was developed by comparison of model predictions with experimental data obtained from shock tube and static reactor...relative to the true gas phase temperature. Air on for exhaust tube cooling•" 2500 0L- CH3 NO 2 off Air off CH3NO 2 on H2 off T Ŕ 1000 S500 Air
Thermal Performance of Microencapsulated Phase Change Material Slurry
2008-03-01
the enhanced tubing to account for the microfin enhancement size. Figure 4.2 suggests that a roughness factor value for an 8 mm enhanced tubing ...After taking into account the enhanced tubing additional surface area, it can be concluded that that the microfins or enhancements on the tubing ...39 4.2 Pressure drop of water with 8 mm enhanced tubing
Thermal Performance of Microencapsulated Phase Change Material Survey
2008-03-01
the enhanced tubing to account for the microfin enhancement size. Figure 4.2 suggests that a roughness factor value for an 8 mm enhanced tubing ...After taking into account the enhanced tubing additional surface area, it can be concluded that that the microfins or enhancements on the tubing ...39 4.2 Pressure drop of water with 8 mm enhanced tubing
Voyager spacecraft images of Jupiter and Saturn
NASA Technical Reports Server (NTRS)
Birnbaum, M. M.
1982-01-01
The Voyager imaging system is described, noting that it is made up of a narrow-angle and a wide-angle TV camera, each in turn consisting of optics, a filter wheel and shutter assembly, a vidicon tube, and an electronics subsystem. The narrow-angle camera has a focal length of 1500 mm; its field of view is 0.42 deg and its focal ratio is f/8.5. For the wide-angle camera, the focal length is 200 mm, the field of view 3.2 deg, and the focal ratio of f/3.5. Images are exposed by each camera through one of eight filters in the filter wheel on the photoconductive surface of a magnetically focused and deflected vidicon having a diameter of 25 mm. The vidicon storage surface (target) is a selenium-sulfur film having an active area of 11.14 x 11.14 mm; it holds a frame consisting of 800 lines with 800 picture elements per line. Pictures of Jupiter, Saturn, and their moons are presented, with short descriptions given of the area being viewed.
Development of a Time-tagged Neutron Source for SNM Detection
Ji, Qing; Ludewigt, Bernhard; Wallig, Joe; ...
2015-06-18
Associated particle imaging (API) is a powerful technique for special nuclear material (SNM) detection and characterization of fissile material configurations. A sealed-tube neutron generator has been under development by Lawrence Berkeley National Laboratory to reduce the beam spot size on the neutron production target to 1 mm in diameter for a several-fold increase in directional resolution and simultaneously increases the maximum attainable neutron flux. A permanent magnet 2.45 GHz microwave-driven ion source has been adopted in this time-tagged neutron source. This type of ion source provides a high plasma density that allows the use of a sub-millimeter aperture for themore » extraction of a sufficient ion beam current and lets us achieve a much reduced beam spot size on target without employing active focusing. The design of this API generator uses a custom-made radial high voltage insulator to minimize source to neutron production target distance and to provide for a simple ion source cooling arrangement. Preliminary experimental results showed that more than 100 µA of deuterium ions have been extracted, and the beam diameter on the neutron production target is around 1 mm.« less
Determination of near-saturated hydraulic conductivity by automated minidisk infiltrometer
NASA Astrophysics Data System (ADS)
Klipa, Vladimir; Snehota, Michal; Dohnal, Michal; Zumr, David
2013-04-01
Numerical models in surface and subsurface hydrology require knowledge of infiltration properties of soils for their routine use in the field of water management, environmental protection or agriculture. A new automated tension infiltration module has been designed at the Faculty of Civil Engineering, Czech Technical University in Prague to facilitate the measurements of near-saturated hydraulic conductivity. In the proposed infiltration module the amount of infiltrated water is registered via changes of buoyant force of stationary float attached to the load cell. Presented setup consists of six mini-disk infiltrometer modules held in the light aluminum frame and two Mariotte's bottles. Three infiltrometer modules connected to each Mariotte's bottle allow performing six simultaneous measurements at two different pressure heads. Infiltration modules are connected to the automatic data logging system and consist of: plastic cover with the integrated load cell and the float, reservoir tube (external diameter of 50 mm), and sintered stainless steel plate (diameter of 44.5 mm). The newly developed device was used for determination of near-saturated hydraulic conductivity of soils in experimental catchments Uhlirska (Jizera Mountains, Northern Bohemia) and Kopaninsky creek (Bohemian-Moravian Highlands). The acquired data show a good agreement with the data obtained from previous measurements.
Suami, Hiroo; Taylor, G Ian; O'Neill, Jennifer; Pan, Wei-Ren
2007-07-01
The authors previously reported a new technique with which to delineate the lymphatic vessels, using hydrogen peroxide to identify them and a lead oxide suspension to demonstrate them on radiographs. This technique provided excellent studies of the lymph vessels in human cadavers, but there was still room for improvement. Lymph collecting vessels run superficially in some regions, where they may be damaged while the surgeon is attempting to find them. Vessels smaller than 0.3 mm in diameter could not be cannulated with a 30-gauge needle, which was the smallest the authors had available, and the lead oxide suspension often blocked this cannula. The authors also encountered problems holding the cannula steady. The authors solved these problems by using a mixture of hydrogen peroxide and ink to better identify the lymphatics, an extruded glass tube instead of a metal needle to cannulate them, an agate pestle and mortar to grind the lead oxide into finer particles, powdered milk to suspend the lead oxide, and a micromanipulator to facilitate accurate and steady cannulation of the vessels. This study developed these modifications to focus on tributaries of the collecting lymphatic channels that are smaller than 0.3 mm in diameter.