Proof-of-Concept of a Millimeter-Wave Integrated Heterogeneous Network for 5G Cellular
Okasaka, Shozo; Weiler, Richard J.; Keusgen, Wilhelm; Pudeyev, Andrey; Maltsev, Alexander; Karls, Ingolf; Sakaguchi, Kei
2016-01-01
The fifth-generation mobile networks (5G) will not only enhance mobile broadband services, but also enable connectivity for a massive number of Internet-of-Things devices, such as wireless sensors, meters or actuators. Thus, 5G is expected to achieve a 1000-fold or more increase in capacity over 4G. The use of the millimeter-wave (mmWave) spectrum is a key enabler to allowing 5G to achieve such enhancement in capacity. To fully utilize the mmWave spectrum, 5G is expected to adopt a heterogeneous network (HetNet) architecture, wherein mmWave small cells are overlaid onto a conventional macro-cellular network. In the mmWave-integrated HetNet, splitting of the control plane (CP) and user plane (UP) will allow continuous connectivity and increase the capacity of the mmWave small cells. mmWave communication can be used not only for access linking, but also for wireless backhaul linking, which will facilitate the installation of mmWave small cells. In this study, a proof-of-concept (PoC) was conducted to demonstrate the practicality of a prototype mmWave-integrated HetNet, using mmWave technologies for both backhaul and access. PMID:27571074
Proof-of-Concept of a Millimeter-Wave Integrated Heterogeneous Network for 5G Cellular.
Okasaka, Shozo; Weiler, Richard J; Keusgen, Wilhelm; Pudeyev, Andrey; Maltsev, Alexander; Karls, Ingolf; Sakaguchi, Kei
2016-08-25
The fifth-generation mobile networks (5G) will not only enhance mobile broadband services, but also enable connectivity for a massive number of Internet-of-Things devices, such as wireless sensors, meters or actuators. Thus, 5G is expected to achieve a 1000-fold or more increase in capacity over 4G. The use of the millimeter-wave (mmWave) spectrum is a key enabler to allowing 5G to achieve such enhancement in capacity. To fully utilize the mmWave spectrum, 5G is expected to adopt a heterogeneous network (HetNet) architecture, wherein mmWave small cells are overlaid onto a conventional macro-cellular network. In the mmWave-integrated HetNet, splitting of the control plane (CP) and user plane (UP) will allow continuous connectivity and increase the capacity of the mmWave small cells. mmWave communication can be used not only for access linking, but also for wireless backhaul linking, which will facilitate the installation of mmWave small cells. In this study, a proof-of-concept (PoC) was conducted to demonstrate the practicality of a prototype mmWave-integrated HetNet, using mmWave technologies for both backhaul and access.
Jain, Aditi; Asrani, Hemant; Singhal, Abhinav Chand; Bhatia, Taranjeet Kaur; Sharma, Vaibhav; Jaiswal, Pragya
2016-01-01
Aims: To compare the canal transportation, centering ability, and remaining dentin thickness of WaveOne and ProTaper systems using cone beam computed tomography. Subjects and Methods: Forty extracted human single-rooted premolars were used in the present study. Preinstrumentation scanning of all teeth was taken; canal curvatures were calculated, and the samples were randomly divided into two groups, with twenty samples in each group; one group was instrumented with WaveOne system and the other group with ProTaper rotary system. Postinstrumentation scans were performed, and the two scans were compared to determine canal transportation, centering ability, and remaining dentin thickness at 3 mm, 6 mm, and 9 mm from the root apex. Statistical Analysis Used: Student's unpaired t-test. Results: Using Student's unpaired t-test, results were as follows: for canal transportation, Group 1 showed significant difference at 3 mm and 6 mm and insignificant difference at 9 mm while Group 2 showed insignificant difference in all the three regions. For centering ability and remaining dentin thickness, Group 1 showed insignificant difference at 3 mm and 9 mm while significant difference at 6 mm was obtained. When comparison of remaining dentin thickness was done at three levels using two groups WaveOne and ProTaper, there was no significant difference between two groups. Conclusions: (1) WaveOne single reciprocation file system respected better canal anatomy better than ProTaper. (2) Individually, centering ability of WaveOne was better at 3 mm, 6 mm, and 9 mm levels. (3) However, ProTaper individually was better centered at 3 mm (apical third) and 9 mm (coronal 3rd) levels than 6 mm level (middle third). PMID:27656063
Investigation of radiant millimeter wave/terahertz radiation from low-infrared signature targets
NASA Astrophysics Data System (ADS)
Aytaç, B.; Alkuş, Ü.; Sivaslıgil, M.; Şahin, A. B.; Altan, H.
2017-10-01
Millimeter (mm) and sub-mm wave radiation is increasingly becoming a region of interest as better methods are developed to detect in this wavelength range. The development of sensitive focal plane array (FPA) architectures as well as single pixel scanners has opened up a new field of passive detection and imaging. Spectral signatures of objects, a long standing area of interest in the Short Wave Infrared (SWIR), Mid-Wave (MWIR) and Long Wave-IR (LWIR) bands can now be assessed in the mm-wave/terahertz (THz) region. The advantage is that this form of radiation is not as adversely affected by poor atmospheric conditions compared to other bands. In this study, a preliminary experiment in a laboratory environment is performed to assess the radiance from targets with low infrared signatures in the millimeter wave/terahertz (THz) band (<1 THz). The goal of this approach is to be able to model the experimental results to better understand the mm-wave/THz signature of targets with low observability in the IR bands.
Evaluating Temperature Changes of Brain Tissue Due to Induced Heating of Cell Phone Waves.
Forouharmajd, Farhad; Pourabdian, Siamak; Ebrahimi, Hossein
2018-01-01
Worries have recently been increased in the absorption of radiofrequency waves and their destructing effects on human health by increasing use of cell phones (mobile phones). This study performed to determine the thermal changes due to mobile phone radio frequency waves in gray and white brain tissue. This study is an empirical study, where the thermal changes of electromagnetic waves resulted from cell phones (900 MHZ, specific absorption rate for head 1.18 w/kg) on the 15 brain tissue of a cow were analyzed in a compartment with three different thickness of 2 mm, 12 mm, and 22 mm, for 15 min. The Lutron thermometer (model: MT-917) with 0.01°C precision was used for measuring the tissue temperature. For each thickness was measured three times. Data analysis is done by Lutron and MATLAB software packages. In confronting of the tissue with the cell phone, the temperature was increased by 0.53°C in the 2 mm thickness that is the gray matter of the brain, increased by 0.99°C in the 12 mm thickness, and also increased by 0.92°C in the 22 mm thickness. Brain temperature showed higher rates than the base temperature after 15 min of confrontation with cell phone waves in all the three thicknesses. Cell phone radiated radio frequency waves were effective on increasing brain tissue temperature, and this temperature increase has cumulative effect on the tissue, being higher, for some time after the confrontation than the time with no confrontation.
Evaluating Temperature Changes of Brain Tissue Due to Induced Heating of Cell Phone Waves
Forouharmajd, Farhad; Pourabdian, Siamak; Ebrahimi, Hossein
2018-01-01
Background: Worries have recently been increased in the absorption of radiofrequency waves and their destructing effects on human health by increasing use of cell phones (mobile phones). This study performed to determine the thermal changes due to mobile phone radio frequency waves in gray and white brain tissue. Methods: This study is an empirical study, where the thermal changes of electromagnetic waves resulted from cell phones (900 MHZ, specific absorption rate for head 1.18 w/kg) on the 15 brain tissue of a cow were analyzed in a compartment with three different thickness of 2 mm, 12 mm, and 22 mm, for 15 min. The Lutron thermometer (model: MT-917) with 0.01°C precision was used for measuring the tissue temperature. For each thickness was measured three times. Data analysis is done by Lutron and MATLAB software packages. Results: In confronting of the tissue with the cell phone, the temperature was increased by 0.53°C in the 2 mm thickness that is the gray matter of the brain, increased by 0.99°C in the 12 mm thickness, and also increased by 0.92°C in the 22 mm thickness. Brain temperature showed higher rates than the base temperature after 15 min of confrontation with cell phone waves in all the three thicknesses. Conclusions: Cell phone radiated radio frequency waves were effective on increasing brain tissue temperature, and this temperature increase has cumulative effect on the tissue, being higher, for some time after the confrontation than the time with no confrontation. PMID:29861880
Tanabe, J; Kitano, K; Suzuki, T; Okayama, Y; Mochizuki, K; Kawasaki, K
1990-01-01
The effects of ceftazidime (CAZ) and flomoxef sodium (FMOX) on the in-vitro electroretinogram (ERG) of albino rabbits were studied. The a-wave, the b-wave and the oscillatory potential (OP) were unchanged by 0.3mM (0.19mg/ml) CAZ-containing solution. The OP was suppressed by 0.5mM (0.32mg/ml) CAZ. The a-wave, the b-wave and the OP were unchanged by 0.5mM (0.26mg/ml) FMOX. The OP was suppressed and its peak latency was delayed by 2mM (0.52mg/ml) FMOX. The concentration of 0.3mM (0.19mg/ml) CAZ was higher than its minimum inhibitory concentration (MIC) against Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Serratia marcescens and Propionibacterium acnes. The concentration of 0.5mM (0.26mg/ml) FMOX was higher than its MIC against Staphylococcus aureus, Staphylococcus epidermidis, Serratia marcescens and Propionibacterium acnes.
Influence of general anaesthesia on slow waves of intracranial pressure.
Lalou, Despina A; Czosnyka, Marek; Donnelly, Joseph; Lavinio, Andrea; Pickard, John D; Garnett, Matthew; Czosnyka, Zofia
2016-07-01
Slow vasogenic intracranial pressure (ICP) waves are spontaneous ICP oscillations with a low frequency bandwidth of 0.3-4 cycles/min (B-waves). B-waves reflect dynamic oscillations in cerebral blood volume associated with autoregulatory cerebral vasodilation and vasoconstriction. This study quantifies the effects of general anaesthesia (GA) on the magnitude of B-waves compared to natural sleep and conscious state. The magnitude of B-waves was assessed in 4 groups of 30 patients each with clinical indications for ICP monitoring. Normal pressure hydrocephalus patients undergoing Cerebrospinal Fluid (CSF) infusion studies in the conscious state (GROUP A) and under GA (GROUP B), and hydrocephalus patients undergoing overnight ICP monitoring during physiological sleep (GROUP C) were compared to deeply sedated traumatic brain injury (TBI) patients with well-controlled ICP during the first night of Intensive Care Unit (ICU) stay (GROUP D). A total of 120 patients were included. During CSF infusion studies, the magnitude of slow waves was higher in conscious patients ( 0.23+/-0.10 mm Hg) when compared to anaesthetised patients ( 0.15+/-0.10 mm Hg; p = 0.011). Overnight magnitude of slow waves was higher in patients during natural sleep (GROUP C: 0.20+/-0.13 mm Hg) when compared to TBI patients under deep sedation (GROUP D: 0.11+/- 0.09 mm Hg; p = 0.002). GA and deep sedation are associated with a reduced magnitude of B-waves. ICP monitoring carried out under GA is affected by iatrogenic suppression of slow vasogenic waves of ICP. Accounting for the effects of anaesthesia on vasogenic waves may prevent the misidentification of potential shunt-responders as non-responders.
NASA Technical Reports Server (NTRS)
Khatun, Mahfuza; Mehrpouyan, Hani; Matolak, David; Guvenc, Ismail
2017-01-01
Millimeter-wave (mmWave) communications will play a key role in enhancing the throughput, reliability, and security of next generation wireless networks. These advancements are achieved through the large bandwidth available in this band and through the use of highly directional links that will be used to overcome the large pathloss at these frequencies. Although the terrestrial application of mmWave systems is advancing at a rapid pace, the use of mmWave communication systems in aviation systems or airports is still in its infancy. This can be attributed to the challenges related to radio technology and lack of development, and characterization of mmWave wireless channels for the aviation field and the airport environment. Consequently, one of our goals is to develop methodologies that support mmWave air to ground links, and various links at airports, by applying new localization schemes that allow for application of highly directional links that can be deployed over longer distances despite the high path loss at mmWave frequencies. However, a very thorough understanding of the mmWave channel models are needed to enable such new applications. To this end, in this paper, we present a survey of the current channel models in the mmWave band. The 3-dimensional statistical channel model is also reviewed and its parameters and typical characteristics for this model are identified and computed through simulation for the Boise metropolitan area.
Experimental and theoretical study of Rayleigh-Lamb wave propagation
NASA Technical Reports Server (NTRS)
Rogers, Wayne P.; Datta, Subhendu K.; Ju, T. H.
1990-01-01
Many space structures, such as the Space Station Freedom, contain critical thin-walled components. The structural integrity of thin-walled plates and shells can be monitored effectively using acoustic emission and ultrasonic testing in the Rayleigh-Lamb wave frequency range. A new PVDF piezoelectric sensor has been developed that is well suited to remote, inservice nondestructive evaluation of space structures. In the present study the new sensor was used to investigate Rayleigh-Lamb wave propagation in a plate. The experimental apparatus consisted of a glass plate (2.3 m x 25.4 mm x 5.6 mm) with PVDF sensor (3 mm diam.) mounted at various positions along its length. A steel ball impact served as a simulated acoustic emission source, producing surface waves, shear waves and longitudinal waves with dominant frequencies between 1 kHz and 200 kHz. The experimental time domain wave-forms were compared with theoretical predictions of the wave propagation in the plate. The model uses an analytical solution for the Green's function and the measured response at a single position to predict response at any other position in the plate. Close agreement was found between the experimental and theoretical results.
Advanced millimeter-wave security portal imaging techniques
NASA Astrophysics Data System (ADS)
Sheen, David M.; Bernacki, Bruce E.; McMakin, Douglas L.
2012-03-01
Millimeter-wave (mm-wave) imaging is rapidly gaining acceptance as a security tool to augment conventional metal detectors and baggage x-ray systems for passenger screening at airports and other secured facilities. This acceptance indicates that the technology has matured; however, many potential improvements can yet be realized. The authors have developed a number of techniques over the last several years including novel image reconstruction and display techniques, polarimetric imaging techniques, array switching schemes, and high-frequency high-bandwidth techniques. All of these may improve the performance of new systems; however, some of these techniques will increase the cost and complexity of the mm-wave security portal imaging systems. Reducing this cost may require the development of novel array designs. In particular, RF photonic methods may provide new solutions to the design and development of the sequentially switched linear mm-wave arrays that are the key element in the mm-wave portal imaging systems. Highfrequency, high-bandwidth designs are difficult to achieve with conventional mm-wave electronic devices, and RF photonic devices may be a practical alternative. In this paper, the mm-wave imaging techniques developed at PNNL are reviewed and the potential for implementing RF photonic mm-wave array designs is explored.
Are Slow Waves of Intracranial Pressure Suppressed by General Anaesthesia?
Lalou, Despina Afroditi; Czosnyka, Marek; Donnelly, Joseph; Lavinio, Andrea; Pickard, John D; Garnett, Matthew; Czosnyka, Zofia
2018-01-01
Slow waves of intracranial pressure (ICP) are spontaneous oscillations with a frequency of 0.3-4 cycles/min. They are often associated with pathological conditions, following vasomotor activity in the cranial enclosure. This study quantifies the effects of general anaesthesia (GA) on the magnitude of B-waves compared with natural sleep and the conscious state. Four groups of 30 patients each were formed to assess the magnitude of slow waves. Group A and group B consisted of normal pressure hydrocephalus (NPH) patients, each undergoing cerebrospinal fluid (CSF) infusion studies, conscious and under GA respectively. Group C comprised conscious, naturally asleep hydrocephalic patients undergoing overnight ICP monitoring; group D, which included deeply sedated head injury patients monitored in the intensive care unit (ICU), was compared with group C. The average amplitude for group A patients was higher (0.23 ± 0.10 mmHg) than that of group B (0.15 ± 0.10 mmHg; p = 0.01). Overnight magnitude of slow waves was higher in group C (0.20 ± 0.13 mmHg) than in group D (0.11 ± 0.09 mmHg; p = 0.002). Slow waves of ICP are suppressed by GA and deep sedation. When using slow waves in clinical decision-making, it is important to consider the patients' level of consciousness to avoid incorrect therapeutic and management decisions.
2011-09-01
detection of a fatigue crack via 3D LDV measurements, both in aluminum plates. All the referenced LDV/guided wave studies made use of PZT or similar...Figure 1a). (b) (a) (c) Figure 1: (a) Test specimen in MTS fatigue test machine, (b) hole with 5 mm crack, (c) PZT placement with...mm thick aluminum plates with a small (1.59 mm) center hole added to facilitate growth of a fatigue crack. One plate was left undamaged while the
Wang, T H-H; Du, P; Angeli, T R; Paskaranandavadivel, N; Erickson, J C; Abell, T L; Cheng, L K; O'Grady, G
2018-01-01
Gastric slow wave dysrhythmias are accompanied by deviations in frequency, velocity, and extracellular amplitude, but the inherent association between these parameters in normal activity still requires clarification. This study quantified these associations using a joint experimental-theoretical approach. Gastric pacing was conducted in pigs with simultaneous high-resolution slow wave mapping (32-256 electrodes; 4-7.6 mm spacing). Relationships between period, velocity, and amplitude were quantified and correlated for each wavefront. Human data from two existing mapping control cohorts were analyzed to extract and correlate these same parameters. A validated biophysically based ICC model was also applied in silico to quantify velocity-period relationships during entrainment simulations and velocity-amplitude relationships from membrane potential equations. Porcine pacing studies identified positive correlations for velocity-period (0.13 mm s -1 per 1 s, r 2 =.63, P<.001) and amplitude-velocity (74 μV per 1 mm s -1 , r 2 =.21, P=.002). In humans, positive correlations were also quantified for velocity-period (corpus: 0.11 mm s -1 per 1 s, r 2 =.16, P<.001; antrum: 0.23 mm s -1 per 1 s, r 2 =.55; P<.001), and amplitude-velocity (94 μV per 1 mm s -1 , r 2 =.56; P<.001). Entrainment simulations matched the experimental velocity-period relationships and demonstrated dependence on the slow wave recovery phase. Simulated membrane potential relationships were close to these experimental results (100 μV per 1 mm s -1 ). These data quantify the relationships between slow wave frequency, velocity, and extracellular amplitude. The results from both human and porcine studies were in keeping with biophysical models, demonstrating concordance with ICC biophysics. These relationships are important in the regulation of gastric motility and will help to guide interpretations of dysrhythmias. © 2017 John Wiley & Sons Ltd.
P-S & S-P Elastic Wave Conversions from Linear Arrays of Oriented Microcracks
NASA Astrophysics Data System (ADS)
Jiang, L.; Modiriasari, A.; Bobet, A.; Pyrak-Nolte, L. J.
2017-12-01
Natural and induced processes can produce oriented mechanical discontinuities such as en echelon cracks, fractures and faults. Previous research has shown that compressional to shear (P-S) wave conversions occur at normal incidence to a fracture because of cross-coupling fracture compliances (Nakagawa et al., 2000). Here, experiments and computer simulation are presented to demonstrate the link among cross-coupling stiffness, microcrack orientation and energy partitioning among P, S, and P-S/S-P waves. A FormLabs 2 3D printer was used to fabricate 7 samples (50 mm x 50 mm x 100 mm) with linear arrays of microcracks oriented at 0, 15, 30, 45, 60, 75, and 900 with a print resolution of 0.025 mm. The microcracks were elliptical in cross-sections (2 mm long by 1 mm wide), through the 50 mm thickness of sample, and spaced 3 mm (center-to-center for adjacent cracks). A 25 mm length of each sample contained no microcracks to act as a reference material. Broadband transducers (0.2-1.5 MHz) were used to transmit and receive P and polarized S wave signals that were propagated at normal incidence to the linear array of microcracks. P-wave amplitude increased, while S-wave amplitude remained relatively constant, as the microcrack orientation increased from 0o to 90o. At normal incidence, P-S and S-P wave conversions emerged and increased in amplitude as the crack inclination increased from 00 to 450. From 450 to 900, the amplitude of these converted modes decreased. Between negative and positive crack angles, the P-to-S and S-to-P waves were 1800 phase reversed. The observed energy partitioning matched the computed compliances obtained from numerical simulations with ABAQUS. The cross-coupling compliance for cracks inclined at 450 was found to be the smallest magnitude. 3D printing enabled the study of microstructural effects on macro-scale wave measurements. Information on the orientation of microcracks or even en echelon fractures and faults is contained in P-S conversions even at normal incidence. Acknowledgment: This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, Geosciences Research Program under Award Number (DE-FG02-09ER16022) and by the National Science Foundation, Geomechanics and Geotechnical Systems Program (award No. CMMI-1162082).
3D structure and kinematics characteristics of EUV wave front
NASA Astrophysics Data System (ADS)
Podladchikova, T.; Veronig, A.; Dissauer, K.
2017-12-01
We present 3D reconstructions of EUV wave fronts using multi-point observations from the STEREO-A and STEREO-B spacecraft. EUV waves are large-scale disturbances in the solar corona that are initiated by coronal mass ejections, and are thought to be large-amplitude fast-mode MHD waves or shocks. The aim of our study is to investigate the dynamic evolution of the 3D structure and wave kinematics of EUV wave fronts. We study the events on December 7, 2007 and February 13, 2009 using data from the STEREO/EUVI-A and EUVI-B instruments in the 195 Å filter. The proposed approach is based on a complementary combination of epipolar geometry of stereo vision and perturbation profiles. We propose two different solutions to the matching problem of the wave crest on images from the two spacecraft. One solution is suitable for the early and maximum stage of event development when STEREO-A and STEREO-B see the different facets of the wave, and the wave crest is clearly outlined. The second one is applicable also at the later stage of event development when the wave front becomes diffuse and is faintly visible. This approach allows us to identify automatically the segments of the diffuse front on pairs of STEREO-A and STEREO-B images and to solve the problem of identification and matching of the objects. We find that the EUV wave observed on December 7, 2007 starts with a height of 30-50 Mm, sharply increases to a height of 100-120 Mm about 10 min later, and decreases to 10-20 Mm in the decay phase. Including the 3D evolution of the EUV wave front allowed us to correct the wave kinematics for projection and changing height effects. The velocity of the wave crest (V=215-266 km/s) is larger than the trailing part of the wave pulse (V=103-163 km/s). For the February 9, 2009 event, the upward movement of the wave crest shows an increase from 20 to 100 Mm over a period of 30 min. The velocity of wave crest reaches values of 208-211 km/s.
Ballistic fractures: indirect fracture to bone.
Dougherty, Paul J; Sherman, Don; Dau, Nathan; Bir, Cynthia
2011-11-01
Two mechanisms of injury, the temporary cavity and the sonic wave, have been proposed to produce indirect fractures as a projectile passes nearby in tissue. The purpose of this study is to evaluate the temporal relationship of pressure waves using strain gauge technology and high-speed video to elucidate whether the sonic wave, the temporary cavity, or both are responsible for the formation of indirect fractures. Twenty-eight fresh frozen cadaveric diaphyseal tibia (2) and femurs (26) were implanted into ordnance gelatin blocks. Shots were fired using 9- and 5.56-mm bullets traversing through the gelatin only, passing close to the edge of the bone, but not touching, to produce an indirect fracture. High-speed video of the impact event was collected at 20,000 frames/s. Acquisition of the strain data were synchronized with the video at 20,000 Hz. The exact time of fracture was determined by analyzing and comparing the strain gauge output and video. Twenty-eight shots were fired, 2 with 9-mm bullets and 26 with 5.56-mm bullets. Eight indirect fractures that occurred were of a simple (oblique or wedge) pattern. Comparison of the average distance of the projectile from the bone was 9.68 mm (range, 3-20 mm) for fractured specimens and 15.15 mm (range, 7-28 mm) for nonfractured specimens (Student's t test, p = 0.036). In this study, indirect fractures were produced after passage of the projectile. Thus, the temporary cavity, not the sonic wave, was responsible for the indirect fractures.
MmWave Vehicle-to-Infrastructure Communication :Analysis of Urban Microcellular Networks
DOT National Transportation Integrated Search
2017-05-01
Vehicle-to-infrastructure (V2I) communication may provide high data rates to vehicles via millimeterwave (mmWave) microcellular networks. This report uses stochastic geometry to analyze the coverage of urban mmWave microcellular networks. Prior work ...
A surface wave elastography technique for measuring tissue viscoelastic properties.
Zhang, Xiaoming
2017-04-01
A surface wave elastography method is proposed to study the viscoelastic properties of skin by measuring the surface wave speed and attenuation on the skin. Experiments were carried out on porcine skin tissues. The surface wave speed is measured by the change of phase with distance. The wave attenuation is measured by the decay of wave amplitude with distance. The change of viscoelastic properties with temperature was studied at room and body temperatures. The wave speed was 1.83m/s at 22°C but reduced to 1.52m/s at 33°C. The viscoelastic ratio was almost constant from 22°C to 33°C. Fresh and decayed tissues were studied. The wave speed of the decayed tissue increased from 1.83m/s of fresh state to 2.73m/s. The viscoelastic ratio was 0.412/mm at the decayed state compared to 0.215/mm at the fresh state. More tissue samples are needed to study these viscoelastic parameters according to specific applications. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Auerbach, D. W.; Carter, T. A.; Vincena, S.
2008-11-01
Satellite measurements in the earth's magnetosphere have associated Alfv'en frequency fluctuations with density depletions striated along the geomagnetic field. This poster presents laboratory studies in the LADP experiment at UCLA modeling this phenomena. Density depletions are pre-formed in the plasma column by selectively blocking a portion of the drive beam, and Alfv'en waves are driven in the cavity by means of an inserted antenna. Relevant experimental parameters include an ion cyclotron radius around a mm, alfven parallel wavelength several meters, electron inertial length around 6 mm, and electron thermal speeds about a third of the alfv'en speed. We report here on modifications to the wave propagation due to the density depletion. We also report on the details of the interactions between the driven wave and the secondary drift-alfv'en wave instabilities that arise on the density boundary, including wave-wave interactions and possible turbulent broadening effects on the main wave.
Interaction of a shock wave with multiple spheres suspended in different arrangements
NASA Astrophysics Data System (ADS)
Zhang, Li-Te; Sui, Zhen-Zhen; Shi, Hong-Hui
2018-03-01
In this study, the unsteady drag force, Fd, drag coefficient, Cd, and the relevant dynamic behaviors of waves caused by the interaction between a planar incident shock wave and a multi-sphere model are investigated by using imbedded accelerometers and a high-speed Schlieren system. The shock wave is produced in a horizontal 200 mm inner diameter circular shock tube with a 2000 mm × 200 mm × 200 mm transparent test section. The time history of Cd is obtained based on band-block and low-pass Fast Fourier Transformation filtering combined with Savitzky-Golay polynomial smoothing for the measured acceleration. The effects of shock Mach number, Ms, geometry of multi-sphere model, nondimensional distance between sphere centers, H, and channel blockage are analyzed. We find that all time histories of Cd have a similar double-peak shaped main structure. It is due to wave reflection, diffraction, interference, and convergence at different positions of the spheres. The peak Fd increases, whereas the peak Cd decreases monotonically with increasing Ms. The increase of shock strength due to shock focusing by upstream spheres increases the peak Fd of downstream spheres. Both the increase in sphere number and the decrease in distance between spheres promote wave interference between neighboring spheres. As long as the wave interference times are shorter than the peak times, the peak Fd and Cd are higher compared to a single sphere.
Head-on collision of normal shock waves with rigid porous materials
NASA Astrophysics Data System (ADS)
Levy, A.; Ben-Dor, G.; Skews, B. W.; Sorek, S.
1993-08-01
The head-on collision of a planar shock wave with a rigid porous material has been investigated experimentally in a 75 mm × 75 mm shock tube. The experimental study indicated that unlike the reflection from a flexible porous material (e.g., polyurethane foam) where the transmitted compression waves do not converge to a sharp shock wave, in the case of a rigid porous material (e.g., alumina) the transmitted compression waves do converge to a sharp shock wave, which decays as it propagates along the porous material. In addition to this major difference, many other differences were observed. They are outlined in the following sections. Based on these observations a suggestion modifying the phenomenology of the reflection/interaction process in the case a porous material with large permeability is proposed.
Equilibrium shoreline response of a high wave energy beach
Yates, M.L.; Guza, R.T.; O'Reilly, W. C.; Hansen, J.E.; Barnard, P.L.
2011-01-01
Four years of beach elevation surveys at Ocean Beach, San Francisco, California, are used to extend an existing equilibrium shoreline change model, previously calibrated with fine sand and moderate energy waves, to medium sand and higher-energy waves. The shoreline, characterized as the cross-shore location of the mean high water contour, varied seasonally by between 30 and 60 m, depending on the alongshore location. The equilibrium shoreline change model relates the rate of horizontal shoreline displacement to the hourly wave energy E and the wave energy disequilibrium, the difference between E and the equilibrium wave energy that would cause no change in the present shoreline location. Values for the model shoreline response coefficients are tuned to fit the observations in 500 m alongshore segments and averaged over segments where the model has good skill and the estimated effects of neglected alongshore sediment transport are relatively small. Using these representative response coefficients for 0.3 mm sand from Ocean Beach and driving the model with much lower-energy winter waves observed at San Onofre Beach (also 0.3 mm sand) in southern California, qualitatively reproduces the small seasonal shoreline fluctuations at San Onofre. This consistency suggests that the shoreline model response coefficients depend on grain size and may be constant, and thus transportable, between sites with similar grain size and different wave climates. The calibrated model response coefficients predict that for equal fluctuations in wave energy, changes in shoreline location on a medium-grained (0.3 mm) beach are much smaller than on a previously studied fine-grained (0.2 mm) beach. Copyright ?? 2011 by the American Geophysical Union.
Millimeter- and Submillimeter-Wave Remote Sensing Using Small Satellites
NASA Technical Reports Server (NTRS)
Ehsan, N.; Esper, J.; Piepmeier, J.; Racette, P.; Wu, D.
2014-01-01
Cloud ice properties and processes play fundamental roles in atmospheric radiation and precipitation. Limited knowledge and poor representation of clouds in global climate models have led to large uncertainties about cloud feedback processes under climate change. Ice clouds have been used as a tuning parameter in the models to force agreement with observations of the radiation budget at the top of the atmosphere, and precipitation at the bottom. The lack of ice cloud measurements has left the cloud processes at intermediate altitudes unconstrained. Millimeter (mm) and submillimeter (submm)-wave radiometry is widely recognized for its potential to fill the cloud measurement gap in the middle and upper troposphere. Analyses have shown that channels from 183900 GHz offer good sensitivity to ice cloud scattering and can provide ice water path (IWP) products to an accuracy of 25 by simultaneously retrieving ice particle size (Dme) and IWP. Therefore, it is highly desirable to develop a cost-effective, compact mm/submm-wave instrument for cloud observations that can be deployed on future small satellites.This paper presents a conceptual study for a mm/submm-wave instrument for multispectral measurements of ice clouds. It discusses previous work at these frequencies by NASA Goddard Space Flight Center (GSFC) and the current instrument study, as well as receiver architectures and their anticipated performance. And finally, it describes a microsatellite prototype intended for use with this mm/submm-wave instrument.
NASA Astrophysics Data System (ADS)
Jang, Jun-keun; Kondo, Kengo; Namita, Takeshi; Yamakawa, Makoto; Shiina, Tsuyoshi
2016-07-01
Shear-wave elastography (SWE) enables the noninvasive and quantitative evaluation of the mechanical properties of human soft tissue. Generally, shear-wave velocity (C S) can be estimated using the time-of-flight (TOF) method. Young’s modulus is then calculated directly from the estimated C S. However, because shear waves in thin-layered media propagate as guided waves, C S cannot be accurately estimated using the conventional TOF method. Leaky Lamb dispersion analysis (LLDA) has recently been proposed to overcome this problem. In this study, we performed both experimental and finite-element (FE) analyses to evaluate the advantages of LLDA over TOF. In FE analysis, we investigated why the conventional TOF is ineffective for thin-layered media. In phantom experiments, C S results estimated using the two methods were compared for 1.5 and 2% agar plates and tube phantoms. Furthermore, it was shown that Lamb waves can be applied to tubular structures by extracting lateral waves traveling in the long axis direction of the tube using a two-dimensional window. Also, the effects of the inner radius and stiffness (or shear wavelength) of the tube on the estimation performance of LLDA were experimentally discussed. In phantom experiments, the results indicated good agreement between LLDA (plate phantoms of 2 mm thickness: 5.0 m/s for 1.5% agar and 7.2 m/s for 2% agar; tube phantoms with 2 mm thickness and 2 mm inner radius: 5.1 m/s for 1.5% agar and 7.0 m/s for 2% agar; tube phantoms with 2 mm thickness and 4 mm inner radius: 5.3 m/s for 1.5% agar and 7.3 m/s for 2% agar) and SWE measurements (bulk phantoms: 5.3 m/s ± 0.27 for 1.5% agar and 7.3 m/s ± 0.54 for 2% agar).
1987-07-01
transmission lines Low - noise mm wave detectors, mixers and amplifiers Multi-GHz chirp transform processors High performance small antenna arrays Multi-GHz A/D...attractive alternative. The overall advantages for HTS mm wave receivers are very- low quantum-limited noise , wide bandwidth, low electrical power...0 0 3 2 1 6 6.3A 0 0 0 2 -3 S Total 2 2 4 S 4 17 116 10, ELF Communication (far term). Extremely low frequency communication via magnetic wave has
Experimental Evaluation of Journal Bearing Stability and New Gas Wave Bearing Materials
NASA Technical Reports Server (NTRS)
Keith, Theo G., Jr.; Dimofte, Florin
1998-01-01
A gas journal bearing, with a wavy surfaces was tested in a range of speeds up to 18,000 RPM to determine its stability in an unloaded condition as a function of the wave amplitude. The bearing, was 50 mm in diameter, 58 mm long and had 0.01 65 mm radial clearance. Three waves were created on the inner surface by deforming the bearing sleeve. The ratio of the wave amplitude to the radial clearance (the wave amplitude ratio) was varied from zero to 0.3.
The mm-wave compact component of an AGN
NASA Astrophysics Data System (ADS)
Behar, Ehud; Vogel, Stuart; Baldi, Ranieri D.; Smith, Krista L.; Mushotzky, Richard F.
2018-07-01
mm-wave emission from active galactic nuclei (AGNs) may hold the key to understanding the physical origin of their radio cores. The correlation between radio/mm and X-ray luminosity may suggest a similar physical origin of the two sources. Since synchrotron self-absorption decreases with frequency, mm-waves probe smaller length-scales than cm-waves. We report on 100 GHz (3 mm) observations with the Combined Array for Research in Millimeter-wave Astronomy of 26 AGNs selected from the hard X-ray Swift/Burst Alert Telescope survey. 20/26 targets were detected at 100 GHz down to the 1 mJy (3σ) sensitivity, which corresponds to optically thick synchrotron source sizes of 10-4-10-3 pc. Most sources show a 100 GHz flux excess with respect to the spectral slope extrapolated from low frequencies. This mm spectral component likely originates from smaller scales than the few-GHz emission. The measured mm sources lie roughly around the Lmm (100 GHz) ˜10-4LX (2-10 keV) relation, similar to a few previously published X-ray selected sources, and hinting perhaps at a common coronal origin.
Picosecond, tunable, high-brightness hard x-ray inverse Compton source at Duke storage ring
NASA Astrophysics Data System (ADS)
Litvinenko, Vladimir N.; Wu, Ying; Burnham, Bentley; Barnett, Genevieve A.; Madey, John M. J.
1995-09-01
We suggest a state-of-the art x-ray source using a compact electron storage ring with modest energy (less than 1 GeV) and a high power mm-wave as an undulator. A source of this type has x-ray energies and brightness comparable with third generation synchrotron light sources while it can be very compact and fit in a small university or industrial laboratory or hospital. We propose to operate an isochronous mm-wave FEL and a hard x-ray inverse Compton source at the Duke storage ring to test this concept. Resonant FEL conditions for the mm- wave will be provided by the off-axis interaction with an electromagnetic wave. A special optical resonator with holes for the e-beam is proposed for pumping a hard x-ray inverse Compton source with very high brightness. Simulation results of mm-wave FEL operation of the Duke storage ring are discussed. Expected performance of mm-wave FEL and hard x-ray inverse Compton source are presented.
Experimental millimeter-wave personal satellite communications system
NASA Technical Reports Server (NTRS)
Suzuki, Yoshiaki; Kimura, Shigeru; Shimada, Masaaki; Tanaka, Masato; Takahashi, Yasuhiro
1991-01-01
Communications Research Laboratory (CRL) has investigated an advanced millimeter (mm)-wave satellite communications system for personal use. Experiments in mm-wave personal satellite communication are to be conducted for 3 years using Japan's Engineering Test Satellite VI (ETS-VI). This paper describes an experimental mm-wave (43/38 GHz) personal satellite communication system, including an onboard transponder and an earth terminal. The on-board transponder is almost completed, and the ground experiment system is still in the design stage. The transponder employs advanced mm-wave solid state technology. It uses 38 GHz high power solid state amplifiers to accelerate the development of mm-wave solid state devices which are indispensable to personal earth terminals. The transponder consists of a 43 GHz receiver with a built-in low noise amplifier, an IF filter section with very narrow bandwidth to improve the carrier-to-noise power ratio of the weak personal communication signal, and two high power amplifiers using newly developed high power Gallium Arsenide (GaAs) metal-semiconductor field effect transistors (MESFETs).
Ginther, O J; Siddiqui, M A R; Araujo, E R; Dangudubiyyam, S V
2017-12-01
Observations were made on follicle dynamics and gonadotropin concentrations in anovulatory wave 2 and ovulatory wave 3 in three-wave interovulatory intervals (n = 15). Hypotheses were not used owing to inadequate availability of rationale. The future dominant follicles for waves 2 and 3 were designated DF2 and DF3 and the largest future subordinate follicles as SF2 and SF3, respectively. The day of expected diameter deviation (day 0) was defined as the day that DF2 or DF3 was closest to 8.5 mm. The first day that DF2 became smaller (P < 0.05) than DF3 was day 2 (10.7 ± 0.2 mm vs 11.8 ± 0.3 mm). The FSH surges 2 and 3 that stimulated waves 2 and 3 were similar at peak concentration, but the postsurge nadir of surge 2 occurred 1 day earlier than for surge 3. An LH increase was not temporally associated with deviation in wave 2, but an increase (P < 0.05) in LH in wave 3 began on day -1. Diameter of SF2 (6.5 ± 0.2 mm) on day 0 was less (P < 0.005) than for SF3 (7.2 ± 0.2 mm). Mean diameter of subordinate follicles in wave 2 did not differ among days. Diameter of subordinate follicles that attained ≥6 mm in wave 3 was greater (interaction, P < 0.02) by day 3 when in the right ovary (RO, 7.4 ± 0.2 mm) than when in the left ovary (LO, 5.6 ± 0.2 mm). The frequency of a conventional classification of deviation (future SF greater than 7.0 mm on day 0) was less (P < 0.001) for wave 2 (1 of 15 waves) than for wave 3 (8 of 15 waves). Novel observations involving DF2 and DF3 were (1) before deviation, diameter of DF2 vs DF3 and an incline in FSH surge 2 vs surge 3 were similar and (2) after deviation, smaller diameter of DF2 vs DF3 by day 2 was associated with an earlier cessation (nadir) in FSH surge 2 vs surge 3 and an absence of an LH increase during deviation. Novel observations involving subordinate follicles ≥6 mm were (1) before deviation, diameters were similar between waves 2 and 3 in association with the similar incline in FSH surges 2 vs 3 and (2) after deviation, a greater diameter increase of subordinates occurred in RO than in LO for wave 3, but an increase did not occur for either ovary in wave 2. The characteristics of diameter deviation were profoundly different between waves 2 and 3 owing to a smaller SF2 than SF3 at deviation but similar diameter of DF2 and DF3. Copyright © 2017 Elsevier Inc. All rights reserved.
[Effects of pressure induced retinal ischemia on ERG in rabbit].
Song, G; Yang, X; Zhang, Z; Zhang, D
2001-12-01
To observe the effects of pressure induced retinal ischemia on electroretinogram(ERG) in rabbit. Retinal ischemia was induced in rabbits by increasing intraocular pressure at 30 mmHg, 60 mmHg, 90 mmHg, 120 mmHg for 45 minutes, and retinal function was monitored by eletroretinography. There was no difference on ERG before or after the experiment both in 30 mmHg group and control one. In 60 mmHg pressure induced ischemia eyes, the amplitudes of the b-wave and OPs wave reduced significantly. Four hours after reperfusion, they were totally recovered. After an ischemic insult of 90 mmHg or 120 mmHg for 45 minutes, there was no response of ERG. Four hours later, the amplitudes of the b-wave and OPs wave were 66.912 +/- 20.157 and 16.423 +/- 3.965 the former, 38.852 +/- 23.438 and 8.610 +/- 12.090 the latter, respectively. These results suggest that higher intraocular pressure causes more severe retina ischemic damage, and less recovery ability.
Groopman, Amber M.; Katz, Jonathan I.; Holland, Mark R.; Fujita, Fuminori; Matsukawa, Mami; Mizuno, Katsunori; Wear, Keith A.; Miller, James G.
2015-01-01
Conventional, Bayesian, and the modified least-squares Prony's plus curve-fitting (MLSP + CF) methods were applied to data acquired using 1 MHz center frequency, broadband transducers on a single equine cancellous bone specimen that was systematically shortened from 11.8 mm down to 0.5 mm for a total of 24 sample thicknesses. Due to overlapping fast and slow waves, conventional analysis methods were restricted to data from sample thicknesses ranging from 11.8 mm to 6.0 mm. In contrast, Bayesian and MLSP + CF methods successfully separated fast and slow waves and provided reliable estimates of the ultrasonic properties of fast and slow waves for sample thicknesses ranging from 11.8 mm down to 3.5 mm. Comparisons of the three methods were carried out for phase velocity at the center frequency and the slope of the attenuation coefficient for the fast and slow waves. Good agreement among the three methods was also observed for average signal loss at the center frequency. The Bayesian and MLSP + CF approaches were able to separate the fast and slow waves and provide good estimates of the fast and slow wave properties even when the two wave modes overlapped in both time and frequency domains making conventional analysis methods unreliable. PMID:26328678
Propagation and Dissipation of MHD Waves in Coronal Holes
NASA Astrophysics Data System (ADS)
Dwivedi, B. N.
2006-11-01
bholadwivedi@gmail.com In view of the landmark result on the solar wind outflow, starting between 5 Mm and 20 Mm above the photosphere in magnetic funnels, we investigate the propagation and dissipation of MHD waves in coronal holes. We underline the importance of Alfvén wave dissipation in the magnetic funnels through the viscous and resistive plasma. Our results show that Alfvén waves are one of the primary energy sources in the innermost part of coronal holes where the solar wind outflow starts. We also consider compressive viscosity and thermal conductivity to study the propagation and dissipation of long period slow longitudinal MHD waves in polar coronal holes. We discuss their likely role in the line profile narrowing, and in the energy budget for coronal holes and the solar wind. We compare the contribution of longitudinal MHD waves with high frequency Alfvén waves.
Angeli, T R; O'Grady, G; Du, P; Paskaranandavadivel, N; Pullan, A J; Bissett, I P; Cheng, L K
2013-05-01
Slow-waves modulate the pattern of small intestine contractions. However, the large-scale spatial organization of intestinal slow-wave pacesetting remains uncertain because most previous studies have had limited resolution. This study applied high-resolution (HR) mapping to evaluate intestinal pacesetting mechanisms and propagation patterns in vivo. HR serosal mapping was performed in anesthetized pigs using flexible arrays (256 electrodes; 32 × 8; 4 mm spacing), applied along the jejunum. Slow-wave propagation patterns, frequencies, and velocities were calculated. Slow-wave initiation sources were identified and analyzed by animation and isochronal activation mapping. Analysis comprised 32 recordings from nine pigs (mean duration 5.1 ± 3.9 min). Slow-wave propagation was analyzed, and a total of 26 sources of slow-wave initiation were observed and classified as focal pacemakers (31%), sites of functional re-entry (23%) and circumferential re-entry (35%), or indeterminate sources (11%). The mean frequencies of circumferential and functional re-entry were similar (17.0 ± 0.3 vs 17.2 ± 0.4 cycle min(-1) ; P = 0.5), and greater than that of focal pacemakers (12.7 ± 0.8 cycle min(-1) ; P < 0.001). Velocity was anisotropic (12.9 ± 0.7 mm s(-1) circumferential vs 9.0 ± 0.7 mm s(-1) longitudinal; P < 0.05), contributing to the onset and maintenance of re-entry. This study has shown multiple patterns of slow-wave initiation in the jejunum of anesthetized pigs. These results constitute the first description and analysis of circumferential re-entry in the gastrointestinal tract and functional re-entry in the in vivo small intestine. Re-entry can control the direction, pattern, and frequency of slow-wave propagation, and its occurrence and functional significance merit further investigation. © 2013 Blackwell Publishing Ltd.
NASA Astrophysics Data System (ADS)
Nakayama, M.; Kawakata, H.; Hirano, S.; Doi, I.; Takahashi, N.
2016-12-01
Transmitted waves at high frequencies attenuate strongly through highly porous media such as shallow ground, although the waves enable us to investigate physical properties of the media with high-spatial resolutions. Nakayama et al. (2015, AGU) tried to investigate the spatio-temporal variations in physical properties of a highly porous sand soil during water injection in laboratory. Accelerometers installed in the sand soil received only the signals of no higher than 0.5 kHz, although they used rectangular waveforms as input signals. The wavelength corresponding to 0.5 kHz is about 400 mm because the measured wave velocity is about 200 m/s. The wavelength is comparable to the path lengths of the transmitted waves, so that it cannot be discussed how the temporal variations in physical properties depend on the paths. In this study, we try to transmit waves with wavelengths much shorter than a sand soil and path lengths through a highly porous sand soil. We make a sand soil (750 mm long, 300 mm wide, and 300 mm high) with porosity about 40%. We install a shaker as a wave source at a deep part in the sand soil. In addition, we install accelerometers, pore pressure gauges, and electrodes at different depths. We inject tap water into the sand soil from the bottom, and record transmitted waves together with pore pressure and electrode voltage until the sand soil becomes saturated. Note that we adopt sweep signals (0.1-10 kHz) as the source so that the shaker can generate high frequency waves more strongly than rectangular signals. Accelerometers receive the signals at least up to 5 kHz during the experiment (Figure 1). The wavelength corresponding to 5 kHz is about 40 mm. In conclusion, we succeed in detecting transmitted waves propagating through the highly porous sand soil whose path lengths are about ten times their wave lengths. Acknowledgment: We are grateful to Takayoshi Kishida for supporting the experiment. This work is supported by JSPS KAKENHI Grant Numbers JP15H02996 and 26750135.
Dodd, Kenneth W; Elm, Kendra D; Smith, Stephen W
2016-07-01
The modified Sgarbossa criteria have been validated as a rule for diagnosis of acute coronary occlusion (ACO) in left bundle branch block (LBBB). However, no analysis has been done on differences in the QRS complex, T-wave, or ST-segment concordance of < 1 mm in the derivation or validation studies. Furthermore, there was no comparison of patients with acute myocardial infarction (AMI) but without ACO (i.e., non-ST-elevation myocardial infarction [non-STEMI]) to patients with ACO or without AMI (no MI). We compare findings involving the QRS amplitude, ST-segment morphology, ST-concordance < 1 mm, and T-waves in patients with LBBB with ACO, non-STEMI, and no MI. Retrospectively, emergency department patients were identified with LBBB and ischemic symptoms but no MI, with angiographically proven ACO, and with non-STEMI. ACO, non-STEMI, and no MI groups consisted of 33, 24, and 105 patients. The sum of the maximum deflection of the QRS amplitude across all leads (ΣQRS) was smaller in patients with ACO than those without ACO (101.5 mm vs. 132.5 mm; p < 0.0001) and a cutoff of ΣQRS < 90 mm was 92% specific. For ACO, non-concave ST-segment morphology was 91% specific, any ST concordance ≥ 1 mm was 95% specific, and any ST concordance ≥ 0.5 mm was 94% sensitive. For non-STEMI, terminal T-wave concordance, analogous to biphasic T-waves, was moderately sensitive at 79%. We found differences in QRS amplitude, ST-segment morphology, and T-waves between patients with LBBB and ACO, non-STEMI, and no MI. However, none of these criteria outperformed the modified Sgarbossa criteria for diagnosis of ACO in LBBB. Copyright © 2016 Elsevier Inc. All rights reserved.
Supersonic Love waves in strong piezoelectrics of symmetry mm2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Darinskii, A. N.; Weihnacht, M.
A study has been made of the Love wave propagation on piezoelectric substrates of symmetry mm2. It has been shown that under certain conditions the velocity of the Love wave exceeds that of shear horizontal (SH) bulk waves in the substrate. This occurs when the slowness curve of SH bulk waves in the substrate either has a concavity or is convex with nearly zero curvature. For such {open_quotes}supersonic{close_quotes} Love waves to appear, it is also required that the substrate as well as the layer be specially oriented and that their material constants fulfill a number of inequalities. Numerical computations havemore » been carried out for a number of structures. The results of numerical computations have been compared with approximate analytical estimations. {copyright} 2001 American Institute of Physics.« less
Wave Tank Studies of Phase Velocities of Short Wind Waves
NASA Astrophysics Data System (ADS)
Ermakov, S.; Sergievskaya, I.; Shchegolkov, Yu.
Wave tank studies of phase velocities of short wind waves have been carried out using Ka-band radar and an Optical Spectrum Analyser. The phase velocities were retrieved from measured radar and optical Doppler shifts, taking into account measurements of surface drift velocities. The dispersion relationship was studied in centimetre (cm)- and millimetre(mm)-scale wavelength ranges at different fetches and wind speeds, both for a clean water surface and for water covered with surfactant films. It is ob- tained that the phase velocities do not follow the dispersion relation of linear capillary- gravity waves, increasing with fetch and, therefore, depending on phase velocities of dominant decimetre (dm)-centimetre-scale wind waves. One thus can conclude that nonlinear cm-mm-scale harmonics bound to the dominant wind waves and propagat- ing with the phase velocities of the decimetric waves are present in the wind wave spectrum. The resulting phase velocities of short wind waves are determined by re- lation between free and bound waves. The relative intensity of the bound waves in the spectrum of short wind waves is estimated. It is shown that this relation depends strongly on the surfactant concentration, because the damping effect due to films is different for free and bound waves; this results to changes of phase velocities of wind waves in the presence of surfactant films. This work was supported by MOD, UK via DERA Winfrith (Project ISTC 1774P) and by RFBR (Project 02-05-65102).
Effects of geometrical parameters on thermal-hydraulic performance of wavy microtube
NASA Astrophysics Data System (ADS)
Khoshvaght-Aliabadi, Morteza; Chamanroy, Zohreh
2018-03-01
Laminar flow and heat transfer characteristics of water flow through wavy microtubes (WMTs) with different values of wave length ( l) and wave amplitude ( a) are investigated experimentally. The tested WMTs are fabricated from copper microtube with the internal diameter of 914 μm. Experiments encompass the Reynolds numbers from 640 to 1950. In order to validate the experimental setup and create a base line for comparison, initial tests are also carried out for a straight microtube. The results show that both the heat transfer coefficient and the pressure drop are strongly affected by the studied geometrical factors. For a given Reynolds number, these parameters increase as the wave length decreases and the wave amplitude increases. However, in the studied ranges, the effect of wave amplitude is more than that of wave length. A considerable thermal-hydraulic factor of 1.78 is obtained for a WMT with l = 14.3 mm and a = 6 mm. Finally, correlations are developed to predict the Colburn factor and friction factor of water flow in the WMTs.
Advanced Millimeter-Wave Imaging Enhances Security Screening
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheen, David M.; Bernacki, Bruce E.; McMakin, Douglas L.
2012-01-12
Millimeter-wave imaging is rapidly gaining acceptance for passenger screening at airports and other secured facilities. This paper details a number of techniques developed over the last several years including novel image reconstruction and display techniques, polarimetric imaging techniques, array switching schemes, as well as high frequency high bandwidth techniques. Implementation of some of these methods will increase the cost and complexity of the mm-wave security portal imaging systems. RF photonic methods may provide new solutions to the design and development of the sequentially switched linear mm-wave arrays that are the key element in the mm-wave portal imaging systems.
Advanced Millimeter-Wave Security Portal Imaging Techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheen, David M.; Bernacki, Bruce E.; McMakin, Douglas L.
2012-04-01
Millimeter-wave imaging is rapidly gaining acceptance for passenger screening at airports and other secured facilities. This paper details a number of techniques developed over the last several years including novel image reconstruction and display techniques, polarimetric imaging techniques, array switching schemes, as well as high frequency high bandwidth techniques. Implementation of some of these methods will increase the cost and complexity of the mm-wave security portal imaging systems. RF photonic methods may provide new solutions to the design and development of the sequentially switched linear mm-wave arrays that are the key element in the mm-wave portal imaging systems.
Millimetre-Wave Backhaul for 5G Networks: Challenges and Solutions.
Feng, Wei; Li, Yong; Jin, Depeng; Su, Li; Chen, Sheng
2016-06-16
The trend for dense deployment in future 5G mobile communication networks makes current wired backhaul infeasible owing to the high cost. Millimetre-wave (mm-wave) communication, a promising technique with the capability of providing a multi-gigabit transmission rate, offers a flexible and cost-effective candidate for 5G backhauling. By exploiting highly directional antennas, it becomes practical to cope with explosive traffic demands and to deal with interference problems. Several advancements in physical layer technology, such as hybrid beamforming and full duplexing, bring new challenges and opportunities for mm-wave backhaul. This article introduces a design framework for 5G mm-wave backhaul, including routing, spatial reuse scheduling and physical layer techniques. The associated optimization model, open problems and potential solutions are discussed to fully exploit the throughput gain of the backhaul network. Extensive simulations are conducted to verify the potential benefits of the proposed method for the 5G mm-wave backhaul design.
Large-amplitude acoustic solitary waves in a Yukawa chain
NASA Astrophysics Data System (ADS)
Sheridan, T. E.; Gallagher, James C.
2017-06-01
We experimentally study the excitation and propagation of acoustic solitary waves in a one-dimensional dusty plasma (i.e. a Yukawa chain) with particles interacting through a screened Coulomb potential. The lattice constant mm. Waves are launched by applying a 100 mW laser pulse to one end of the chain for laser pulse durations from 0.10 to 2.0 s. We observe damped solitary waves which propagate for distances with an acoustic speed s=11.5\\pm 0.2~\\text{mm}~\\text{s}-1$ . The maximum velocity perturbation increases with laser pulse duration for durations s and then saturates at . The wave speed is found to be independent of the maximum amplitude, indicating that the formation of nonlinear solitons is prevented by neutral-gas damping.
The compression and expansion waves of the forward and backward flows: an in-vitro arterial model.
Feng, J; Khir, A W
2008-05-01
Although the propagation of arterial waves of forward flows has been studied before, that of backward flows has not been thoroughly investigated. The aim of this research is to investigate the propagation of the compression and expansion waves of backward flows in terms of wave speed and dissipation, in flexible tubes. The aim is also to compare the propagation of these waves with those of forward flows. A piston pump generated a flow waveform in the shape of approximately half-sinusoid, in flexible tubes (12 mm and 16 mm diameter). The pump produced flow in either the forward or the backward direction by moving the piston forward, in a 'pushing action' or backward, in a 'pulling action', using a graphite brushes d.c. motor. Pressure and flow were measured at intervals of 5 cm along each tube and wave speed was determined using the PU-loop method. The simultaneous measurements of diameter were also taken at the same position of the pressure and flow in the 16 mm tube. Wave intensity analysis was used to determine the magnitude of the pressure and velocity waveforms and wave intensity in the forward and backward directions. Under the same initial experimental conditions, wave speed was higher during the pulling action (backward flow) than during the pushing action (forward flow). The amplitudes of pressure and velocity in the pulling action were significantly higher than those in the pushing action. The tube diameter was approximately 20 per cent smaller in the pulling action than in the pushing action in the 16 mm tube. The compression and expansion waves resulting from the pushing and pulling actions dissipated exponentially along the travelling distance, and their dissipation was greater in the smaller than in the larger tubes. Local wave speed in flexible tubes is flow direction- and wave nature-dependent and is greater with expansion than with compression waves. Wave dissipation has an inverse relationship with the vessel diameter, and dissipation of the expansion wave of the pulling action was greater than that of the pushing action.
2018-01-01
As an intrinsic part of the Internet of Things (IoT) ecosystem, machine-to-machine (M2M) communications are expected to provide ubiquitous connectivity between machines. Millimeter-wave (mmWave) communication is another promising technology for the future communication systems to alleviate the pressure of scarce spectrum resources. For this reason, in this paper, we consider multi-hop M2M communications, where a machine-type communication (MTC) device with the limited transmit power relays to help other devices using mmWave. To be specific, we focus on hop distance statistics and their impacts on system performances in multi-hop wireless networks (MWNs) with directional antenna arrays in mmWave for M2M communications. Different from microwave systems, in mmWave communications, wireless channel suffers from blockage by obstacles that heavily attenuate line-of-sight signals, which may result in limited per-hop progress in MWNs. We consider two routing strategies aiming at different types of applications and derive the probability distributions of their hop distances. Moreover, we provide their baseline statistics assuming the blockage-free scenario to quantify the impact of blockages. Based on the hop distance analysis, we propose a method to estimate the end-to-end performances (e.g., outage probability, hop count, and transmit energy) of the mmWave MWNs, which provides important insights into mmWave MWN design without time-consuming and repetitive end-to-end simulation. PMID:29329248
Jung, Haejoon; Lee, In-Ho
2018-01-12
As an intrinsic part of the Internet of Things (IoT) ecosystem, machine-to-machine (M2M) communications are expected to provide ubiquitous connectivity between machines. Millimeter-wave (mmWave) communication is another promising technology for the future communication systems to alleviate the pressure of scarce spectrum resources. For this reason, in this paper, we consider multi-hop M2M communications, where a machine-type communication (MTC) device with the limited transmit power relays to help other devices using mmWave. To be specific, we focus on hop distance statistics and their impacts on system performances in multi-hop wireless networks (MWNs) with directional antenna arrays in mmWave for M2M communications. Different from microwave systems, in mmWave communications, wireless channel suffers from blockage by obstacles that heavily attenuate line-of-sight signals, which may result in limited per-hop progress in MWNs. We consider two routing strategies aiming at different types of applications and derive the probability distributions of their hop distances. Moreover, we provide their baseline statistics assuming the blockage-free scenario to quantify the impact of blockages. Based on the hop distance analysis, we propose a method to estimate the end-to-end performances (e.g., outage probability, hop count, and transmit energy) of the mmWave MWNs, which provides important insights into mmWave MWN design without time-consuming and repetitive end-to-end simulation.
NASA Astrophysics Data System (ADS)
Chauvin, A.; Jourdan, G.; Daniel, E.; Houas, L.; Tosello, R.
2011-11-01
We conducted a series of shock tube experiments to study the influence of a cloud of water droplets on the propagation of a planar shock wave. In a vertically oriented shock tube, the cloud of droplets was released downwards into the air at atmospheric pressure while the shock wave propagated upwards. Two shock wave Mach numbers, 1.3 and 1.5, and three different heights of clouds, 150 mm, 400 mm, and 700 mm, were tested with an air-water volume fraction and a droplet diameter fixed at 1.2% and 500 μm, respectively. From high-speed visualization and pressure measurements, we analyzed the effect of water clouds on the propagation of the shock wave. It was shown that the pressure histories recorded in the two-phase gas-liquid mixture are different from those previously obtained in the gas-solid case. This different behavior is attributed to the process of atomization of the droplets, which is absent in the gas-solid medium. Finally, it was observed that the shock wave attenuation was dependent on the exchange surface crossed by the shock combined with the breakup criterion.
Ignition and growth reactive flow modeling of recent HMX/TATB detonation experiments
NASA Astrophysics Data System (ADS)
Tarver, Craig M.
2017-01-01
Two experimental studies in which faster HMX detonation waves produced oblique detonation waves in adjoining slower detonating TATB charges were modeled using the Ignition and Growth (I&G) reactive flow detonation model parameters for PBX 9501 (95% HMX / 2.5% Estane / 2.5% BDNPA/F) and PBX 9502 (95% TATB / 5% Kel-F binder). Matignon et al. used X1 explosive (96% HMX / 4% binder) to drive an oblique detonation wave into an attached charge of T2 explosive (97% TATB / 3% binder). The flow angles were measured in the T2 shock initiation region and in steady T2 detonation. Anderson et al. used detonating PBX 9501 slabs of various thicknesses ranging from 0.56 mm to 2.5 mm to create oblique detonation waves in 8 mm thick slabs of PBX 9502. Several diagnostics were employed to: photograph the waves; measure detonation velocities and flow angles; and determine the output of the PBX 9501 slabs, the PBX 9502 slabs, and the "initiation regions" using LiF windows and PDV probes.
Bogeski, G; Shafton, A D; Kitchener, P D; Ferens, D M; Furness, J B
2005-04-01
We have developed methods that allow correlation of propulsive reflexes of the intestine with measurements of intraluminal pressure, fluid movement and spatio-temporal maps of intestinal wall movements for the first time in vivo. A segment of jejunum was cannulated and set up in a Trendelenburg recording system while remaining connected to the vascular and nerve supply of the anaesthetized rat. The resting intraluminal pressure in intact intestine was 2-4 mmHg. Hydrostatic pressures of 2, 4, 8 and 16 mmHg were imposed. At a baseline pressure of 4 mmHg, propulsive waves generated pressures of 9 +/- 1 mmHg, that progressed oral to anal at 2-5 mm s(-1). Individual propulsive waves propelled 0.8 +/- 0.4 mL of fluid. The frequency of propulsive waves increased with pressure, but peristaltic efficiency (mL per contraction) decreased with pressure increase between 4 and 16 mmHg. Atropine, as a bolus, transiently blocked peristalsis, but caused maintained block when infused. Hexamethonium blocked propulsive contractions. Inhibition of nitrergic transmission converted regular peristalsis to non-propulsive contractions. These studies demonstrate the utility of an adapted Trendelenburg method for quantitative investigation of motility and pharmacology of enteric reflexes in vivo.
Transmission line model and fields analysis of metamaterial absorber in the terahertz band.
Wen, Qi-Ye; Xie, Yun-Song; Zhang, Huai-Wu; Yang, Qing-Hui; Li, Yuan-Xun; Liu, Ying-Li
2009-10-26
Metamaterial (MM) absorber is a novel device to provide near-unity absorption to electromagnetic wave, which is especially important in the terahertz (THz) band. However, the principal physics of MM absorber is still far from being understood. In this work, a transmission line (TL) model for MM absorber was proposed, and with this model the S-parameters, energy consumption, and the power loss density of the absorber were calculated. By this TL model, the asymmetric phenomenon of THz absorption in MM absorber is unambiguously demonstrated, and it clarifies that strong absorption of this absorber under studied is mainly related to the LC resonance of the split-ring-resonator structure. The distribution of power loss density in the absorber indicates that the electromagnetic wave is firstly concentrated into some specific locations of the absorber and then be strongly consumed. This feature as electromagnetic wave trapper renders MM absorber a potential energy converter. Based on TL model, some design strategies to widen the absorption band were also proposed for the purposes to extend its application areas.
Technology considerations in EHF Satcom systems
NASA Astrophysics Data System (ADS)
Cuccia, C. L.
The history of mm-wave communications is reviewed briefly and technological requirements for future implementation of mm-wave communications satellites for military and commercial applications are surveyed. The driving force for expanding mm-wave usage is an impending saturation of the GEO arc over North America with C- and Ku-band Satcoms. For military purposes, 44 GHz operations would provide antijamming capabilities and on-board processing. Necessary developments for the mm-wave Satcoms include scanning and multiple beam antennas, low-noise amplifiers, filters which channelize the frequency band, frequency hopping synthesizers, QPSK and MSK modulation systems and improvements in GaAs and indium phosphide ICs. Finally, digital systems are being explored for commercial integrated global data, voice and video systems.
Measuring Liquid-Level Utilizing Wedge Wave
Honma, Yudai; Mori, Masayuki; Ihara, Ikuo
2017-01-01
A new technique for measuring liquid-level utilizing wedge wave is presented and demonstrated through FEM simulation and a corresponding experiment. The velocities of wedge waves in the air and the water, and the sensitivities for the measurement, are compared with the simulation and the results obtained in the experiments. Combining the simulation and the measurement theory, it is verified that the foundation framework for the methods is available. The liquid-level sensing is carried out using the aluminum waveguide with a 30° wedge in the water. The liquid-level is proportional to the traveling time of the mode 1 wedge wave. The standard deviations and the uncertainties of the measurement are 0.65 mm and 0.21 mm using interface echo, and 0.39 mm and 0.12 mm utilized by end echo, which are smaller than the industry standard of 1.5 mm. The measurement resolutions are 7.68 μm using the interface echo, which is the smallest among all the guided acoustic wave-based liquid-level sensing. PMID:29267232
Zhou, Boran; Sit, Arthur J; Zhang, Xiaoming
2017-11-01
The objective of this study was to extend an ultrasound surface wave elastography (USWE) technique for noninvasive measurement of ocular tissue elastic properties. In particular, we aim to establish the relationship between the wave speed of cornea and the intraocular pressure (IOP). Normal ranges of IOP are between 12 and 22mmHg. Ex vivo porcine eye balls were used in this research. The porcine eye ball was supported by the gelatin phantom in a testing container. Some water was pour into the container for the ultrasound measurement. A local harmonic vibration was generated on the side of the eye ball. An ultrasound probe was used to measure the wave propagation in the cornea noninvasively. A 25 gauge butterfly needle was inserted into the vitreous humor of the eye ball under the ultrasound imaging guidance. The needle was connected to a syringe. The IOP was obtained by the water height difference between the water level in the syringe and the water level in the testing container. The IOP was adjusted between 5mmHg and 30mmHg with a 5mmHg interval. The wave speed was measured at each IOP for three frequencies of 100, 150 and 200Hz. Finite element method (FEM) was used to simulate the wave propagation in the corneal according to our experimental setup. A linear viscoelastic FEM model was used to compare the experimental data. Both the experiments and the FEM analyses showed that the wave speed of cornea increased with IOP. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Tian, Bo; Zhang, Qi; Ma, Jianxin; Tao, Ying; Shen, Yufei; Wang, Yang; Zhang, Geng; Zhou, Wenmao; Zhao, Yi; Pan, Xiaolong
2018-07-01
A polarization division multiplexed (PDM) microwave photonic link for the millimeter (MM)-wave signal with hybrid modulation scheme is proposed in this paper, which is based on the combination of quadrature amplitude modulation, multi-pulse pulse-position modulation and return to zero modulation (QAM-MPPM-RZ). In this scheme, the two orthogonal polarization states enable simultaneous transmission of four data flows, which can provide different services for users according to the data rate requirement. To generate hybrid QAM-MPPM-RZ mm-wave signal, the QAM mm-wave signal is directly modulated by MPPM-RZ signal without using digital signal processing (DSP) devices, which reduces the overhead of the encoding process. Then, the generated QAM-MPPM-RZ mm-wave signal is transmitted in PDM microwave photonic link based on SSB modulation. The sparsity characteristic of QAM-MPPM-RZ not only improves the power efficiency, but also decreases the degradation caused by the fiber chromatic dispersion. The simulation results show that, under the constraint of the same transmitted data rate, the PDM microwave photonic link with 50 GHz QAM-MPPM-RZ mm-wave signal achieves much lower levels of bit-error rate than ordinary 32-QAM. In addition, the increase of laser linewidth brings no additional impact to the proposed scheme.
Rompe, J D; Bohl, J; Riehle, H M; Schwitalle, M; Krischek, O
1998-01-01
The aim of the study was to evaluate the likeliness for peripheral nerve lesions following extracorporeal shock wave application. 82 rabbit sciatic nerves were randomized to undergo low-energetic (0.08 mJ/mm2), middle-energetic (0.28 mJ/mm2) or no (controls) shock wave therapy. After 1 to 28 days an independent neuropathologist checked the specimen for signs of neural lesions. Only after 14 and 28 days vacuolic swelling of the axons was noted, somewhat pronounced in the middle-energetic group. In no case was there any disruption of the nerve's continuity. We did not observe any neurapraxia. Shock wave application does not threaten peripheral nerve integrity in an animal model.
Santini, Ario; Naaman, Reem Khalil; Aldossary, Mohammed Saeed
2017-04-01
To quantify light energy transmission through two bulk-fill resin-based composites and to measure the top to bottom surface Vickers hardness ratio (VHratio) of samples of various incremental thicknesses, using either a single-wave or dual-wave light curing unit (LCU). Tetric EvoCeram Bulk Fill (TECBF) and SonicFill (SF) were studied. Using MARC-RC, the irradiance delivered to the top surface of the samples 2, 3, 4 and 5 mm thick (n= 5 for each thickness) was adjusted to 800 mW/cm2 for 20 seconds (16 J/cm2) using either a single-wave, Bluephase or a dual-wave, Bluephase G2 LCUs. Light energy transmission through to the bottom surface of the specimens was measured at real time using MARC-RC. The Vickers hardness (VH) was determined using Vickers micro hardness tester and the VHratio was calculated. Data were analyzed using a general linear model in Minitab 16; α= 0.05. TECBF was more translucent than SF (P< 0.05). The mean VHratio was higher than 80% in 2, 3 and 4 mm increment thickness for both materials (except for 4 mm TECBF when cured with the dual-wave Bluephase G2). SF showed significantly higher VH ratio than TECBF at all different thickness levels (P< 0.05), except at the 2 mm level (P> 0.05). TECBF showed significantly greater VH ratio when cured with the single-wave Bluephase than when using the dual-wave Bluephase G2 (P< 0.05). The transmission of light energy through to the bottom surface and the VHratio are material dependent. Although TECBF is more translucent than SF, it showed lower VHratio compared to SF when cured with dual-wave Bluephase G2.
Millimetre-Wave Backhaul for 5G Networks: Challenges and Solutions
Feng, Wei; Li, Yong; Jin, Depeng; Su, Li; Chen, Sheng
2016-01-01
The trend for dense deployment in future 5G mobile communication networks makes current wired backhaul infeasible owing to the high cost. Millimetre-wave (mm-wave) communication, a promising technique with the capability of providing a multi-gigabit transmission rate, offers a flexible and cost-effective candidate for 5G backhauling. By exploiting highly directional antennas, it becomes practical to cope with explosive traffic demands and to deal with interference problems. Several advancements in physical layer technology, such as hybrid beamforming and full duplexing, bring new challenges and opportunities for mm-wave backhaul. This article introduces a design framework for 5G mm-wave backhaul, including routing, spatial reuse scheduling and physical layer techniques. The associated optimization model, open problems and potential solutions are discussed to fully exploit the throughput gain of the backhaul network. Extensive simulations are conducted to verify the potential benefits of the proposed method for the 5G mm-wave backhaul design. PMID:27322265
Towards 5G: A Photonic Based Millimeter Wave Signal Generation for Applying in 5G Access Fronthaul.
Alavi, S E; Soltanian, M R K; Amiri, I S; Khalily, M; Supa'at, A S M; Ahmad, H
2016-01-27
5G communications require a multi Gb/s data transmission in its small cells. For this purpose millimeter wave (mm-wave) RF signals are the best solutions to be utilized for high speed data transmission. Generation of these high frequency RF signals is challenging in electrical domain therefore photonic generation of these signals is more studied. In this work, a photonic based simple and robust method for generating millimeter waves applicable in 5G access fronthaul is presented. Besides generating of the mm-wave signal in the 60 GHz frequency band the radio over fiber (RoF) system for transmission of orthogonal frequency division multiplexing (OFDM) with 5 GHz bandwidth is presented. For the purpose of wireless transmission for 5G application the required antenna is designed and developed. The total system performance in one small cell was studied and the error vector magnitude (EVM) of the system was evaluated.
Towards 5G: A Photonic Based Millimeter Wave Signal Generation for Applying in 5G Access Fronthaul
Alavi, S. E.; Soltanian, M. R. K.; Amiri, I. S.; Khalily, M.; Supa’at, A. S. M.; Ahmad, H.
2016-01-01
5G communications require a multi Gb/s data transmission in its small cells. For this purpose millimeter wave (mm-wave) RF signals are the best solutions to be utilized for high speed data transmission. Generation of these high frequency RF signals is challenging in electrical domain therefore photonic generation of these signals is more studied. In this work, a photonic based simple and robust method for generating millimeter waves applicable in 5G access fronthaul is presented. Besides generating of the mm-wave signal in the 60 GHz frequency band the radio over fiber (RoF) system for transmission of orthogonal frequency division multiplexing (OFDM) with 5 GHz bandwidth is presented. For the purpose of wireless transmission for 5G application the required antenna is designed and developed. The total system performance in one small cell was studied and the error vector magnitude (EVM) of the system was evaluated. PMID:26814621
Towards 5G: A Photonic Based Millimeter Wave Signal Generation for Applying in 5G Access Fronthaul
NASA Astrophysics Data System (ADS)
Alavi, S. E.; Soltanian, M. R. K.; Amiri, I. S.; Khalily, M.; Supa'At, A. S. M.; Ahmad, H.
2016-01-01
5G communications require a multi Gb/s data transmission in its small cells. For this purpose millimeter wave (mm-wave) RF signals are the best solutions to be utilized for high speed data transmission. Generation of these high frequency RF signals is challenging in electrical domain therefore photonic generation of these signals is more studied. In this work, a photonic based simple and robust method for generating millimeter waves applicable in 5G access fronthaul is presented. Besides generating of the mm-wave signal in the 60 GHz frequency band the radio over fiber (RoF) system for transmission of orthogonal frequency division multiplexing (OFDM) with 5 GHz bandwidth is presented. For the purpose of wireless transmission for 5G application the required antenna is designed and developed. The total system performance in one small cell was studied and the error vector magnitude (EVM) of the system was evaluated.
The mm-wave compact component of AGN
NASA Astrophysics Data System (ADS)
Behar, Ehud; Vogel, Stuart; Baldi, Ranieri D.; Smith, Krista L.; Mushotzky, Richard F.
2018-05-01
mm-wave emission from Active Galactic Nuclei (AGN) may hold the key to understanding the physical origin of their radio cores. The correlation between radio/mm and X-ray luminosity may suggest a similar physical origin of the two sources. Since synchrotron self absorption decreases with frequency, mm-waves probe smaller length scales than cm-waves. We report on 100 GHz (3 mm) observations with CARMA of 26 AGNs selected from the hard X-ray Swift/BAT survey. 20/26 targets were detected at 100 GHz down to the 1 mJy (3σ) sensitivity, which corresponds to optically thick synchrotron source sizes of 10-4 - 10-3 pc. Most sources show a 100 GHz flux excess with respect to the spectral slope extrapolated from low frequencies. This mm spectral component likely originates from smaller scales than the few-GHz emission. The measured mm sources lie roughly around the Lmm (100 GHz) ˜10-4LX (2-10 keV) relation, similar to a few previously published X-ray selected sources, and hinting perhaps at a common coronal origin.
A TWT upgrade to study wave-particle interactions in plasma
NASA Astrophysics Data System (ADS)
Doveil, Fabrice; Caetano de Sousa, Meirielen; Guyomarc'h, Didier; Kahli, Aissa; Elskens, Yves
2015-11-01
Beside industrial applications, Traveling Wave Tubes (TWT) are useful to mimic and study wave-particle interaction in plasma. We upgraded a TWT, whose slow wave structure is a 4 m long helix (diameter 3.4 cm, pitch 1 mm) of Be-Cu wire (diameter 0.6 mm) wrapped in insulating tape. The helix is inserted in a vacuum glass tube. At one end, an electron gun produces a beam propagating along the helix, radially confined by a constant axial magnetic field. Movable probes, capacitively coupled to the helix through the glass tube, launch and monitor waves generated by an arbitrary waveform generator at a few tens of MHz. At the other end of the helix, a trochoidal analyzer allows to reconstruct the electron distribution functions of the beam after its self-consistent interaction with the waves. Linear properties of the new device will be reported. The measured coupling coefficients of each probe with the helix are used to reconstruct the growth and saturation of a launched wave as it interacts with the electron beam. J-B. Faure and V. Long are thanked for their efficient help in designing and using a new way to build the helix.
Complexities of follicle deviation during selection of a dominant follicle in Bos taurus heifers.
Ginther, O J; Baldrighi, J M; Siddiqui, M A R; Araujo, E R
2016-11-01
Follicle deviation during a follicular wave is a continuation in growth rate of the dominant follicle (F1) and decreased growth rate of the largest subordinate follicle (F2). The reliability of using an F1 of 8.5 mm to represent the beginning of expected deviation for experimental purposes during waves 1 and 2 (n = 26 per wave) was studied daily in heifers. Each wave was subgrouped as follows: standard subgroup (F1 larger than F2 for 2 days preceding deviation and F2 > 7.0 mm on the day of deviation), undersized subgroup (F2 did not attain 7.0 mm by the day of deviation), and switched subgroup (F2 larger than F1 at least once on the 2 days before or on the day of deviation). For each wave, mean differences in diameter between F1 and F2 changed abruptly at expected deviation in the standard subgroup but began 1 day before expected deviation in the undersized and switched subgroups. Concentrations of FSH in the wave-stimulating FSH surge and an increase in LH centered on expected deviation did not differ among subgroups. Results for each wave indicated that (1) expected deviation (F1, 8.5 mm) was a reliable representation of actual deviation in the standard subgroup but not in the undersized and switched subgroups; (2) concentrations of the gonadotropins normalized to expected deviation were similar among the three subgroups, indicating that the day of deviation was related to diameter of F1 and not F2; and (3) defining an expected day of deviation for experimental use should consider both diameter of F1 and the characteristics of deviation. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Junwei; Chen, Ruizhu; Hartlep, Thomas
2015-08-10
Helioseismic and magnetohydrodynamic waves are abundant in and above sunspots. Through cross-correlating oscillation signals in the photosphere observed by the Solar Dynamics Observatory/Helioseismic and Magnetic Imager, we reconstruct how waves propagate away from virtual wave sources located inside a sunspot. In addition to the usual helioseismic wave, a fast-moving wave is detected traveling along the sunspot’s radial direction from the umbra to about 15 Mm beyond the sunspot boundary. The wave has a frequency range of 2.5–4.0 mHz with a phase velocity of 45.3 km s{sup −1}, substantially faster than the typical speeds of Alfvén and magnetoacoustic waves in themore » photosphere. The observed phenomenon is consistent with a scenario of that a magnetoacoustic wave is excited at approximately 5 Mm beneath the sunspot. Its wavefront travels to and sweeps across the photosphere with a speed higher than the local magnetoacoustic speed. The fast-moving wave, if truly excited beneath the sunspot’s surface, will help open a new window for studying the internal structure and dynamics of sunspots.« less
Configuration study of new low-loss MM (Millimeter) wave guiding structures
NASA Astrophysics Data System (ADS)
Yeh, C.
1985-11-01
The result of the research carried out at EMtec Engineering, Inc., Los Angeles, under Contract DAAG 29-84-C-0025 with the Army Research Office is discussed. The primary objective was to learn whether there exists a dielectric waveguide configuration which offers lower loss figure than a circular dielectric rod. Important evidence was found which showed that it is feasible to optimize a configuration to achieve low-loss guidance of mm waves. Future research areas are also described.
Zhang, Junwen; Yu, Jianjun; Chi, Nan; Li, Fan; Li, Xinying
2013-11-04
We propose and demonstrate a novel CAP-ROF system based on multi-level carrier-less amplitude and phase modulation (CAP) 64QAM with high spectrum efficiency for mm-wave fiber-wireless transmission. The performance of novel CAP modulation with high order QAM, for the first time, is investigated in the mm-wave fiber-wireless transmission system. One I/Q modulator is used for mm-wave generation and base-band signal modulation based on optical carrier suppression (OCS) and intensity modulation. Finally, we demonstrated a 24-Gb/s CAP-64QAM radio-over-fiber (ROF) system over 40-km stand single-mode-fiber (SMMF) and 1.5-m 38-GHz wireless transmission. The system operation factors are also experimentally investigated.
Optical mm-wave generation by using external modulator based on optical carrier suppression
NASA Astrophysics Data System (ADS)
Ma, Jianxin; Yu, Chongxiu; Zhou, Zhen; Yu, Jianjun
2006-12-01
In this paper, we have theoretically investigated the transmission performance of the optical millimeter (mm)-wave generated by using an external modulator based on optical carrier suppression for the first time. According to our theory, the data signals carried by the optical mm-wave are transmitted in the dispersion fiber without fading but are degraded greatly because of the time shift of the code edges, which still limits the transmission distance. The experimental results agree well with our theory.
Where, When, and How mmWave is Used in 5G and Beyond
NASA Astrophysics Data System (ADS)
Sakaguchi, Kei; Haustein, Thomas; Barbarossa, Sergio; Strinati, Emilio Calvanese; Clemente, Antonio; Destino, Giuseppe; Pärssinen, Aarno; Kim, Ilgyu; Chung, Heesang; Kim, Junhyeong; Keusgen, Wilhelm; Weiler, Richard J.; Takinami, Koji; Ceci, Elena; Sadri, Ali; Xian, Liang; Maltsev, Alexander; Tran, Gia Khanh; Ogawa, Hiroaki; Mahler, Kim; Heath, Robert W., Jr.
Wireless engineers and business planners commonly raise the question on where, when, and how millimeter-wave (mmWave) will be used in 5G and beyond. Since the next generation network is not just a new radio access standard, but instead an integration of networks for vertical markets with diverse applications, answers to the question depend on scenarios and use cases to be deployed. This paper gives four 5G mmWave deployment examples and describes in chronological order the scenarios and use cases of their probable deployment, including expected system architectures and hardware prototypes. The paper starts with 28 GHz outdoor backhauling for fixed wireless access and moving hotspots, which will be demonstrated at the PyeongChang winter Olympic games in 2018. The second deployment example is a 60 GHz unlicensed indoor access system at the Tokyo-Narita airport, which is combined with Mobile Edge Computing (MEC) to enable ultra-high speed content download with low latency. The third example is mmWave mesh network to be used as a micro Radio Access Network ({\\mu}-RAN), for cost-effective backhauling of small-cell Base Stations (BSs) in dense urban scenarios. The last example is mmWave based Vehicular-to-Vehicular (V2V) and Vehicular-to-Everything (V2X) communications system, which enables automated driving by exchanging High Definition (HD) dynamic map information between cars and Roadside Units (RSUs). For 5G and beyond, mmWave and MEC will play important roles for a diverse set of applications that require both ultra-high data rate and low latency communications.
A new shock wave assisted sandalwood oil extraction technique
NASA Astrophysics Data System (ADS)
Arunkumar, A. N.; Srinivasa, Y. B.; Ravikumar, G.; Shankaranarayana, K. H.; Rao, K. S.; Jagadeesh, G.
A new shock wave assisted oil extraction technique from sandalwood has been developed in the Shock Waves Lab, IISc, Bangalore. The fragrant oil extracted from sandalwood finds variety of applications in medicine and perfumery industries. In the present method sandal wood specimens (2.5mm diameter and 25mm in length)are subjected to shock wave loading (over pressure 15 bar)in a constant area shock tube, before extracting the sandal oil using non-destructive oil extraction technique. The results from the study indicates that both the rate of extraction as well as the quantity of oil obtained from sandal wood samples exposed to shock waves are higher (15-40 percent) compared to non-destructive oil extraction technique. The compressive squeezing of the interior oil pockets in the sandalwood specimen due to shock wave loading appears to be the main reason for enhancement in the oil extraction rate. This is confirmed by the presence of warty structures in the cross-section and micro-fissures in the radial direction of the wood samples exposed to shock waves in the scanning electron microscopic investigation. In addition the gas chromatographic studies do not show any change in the q uality of sandal oil extracted from samples exposed to shock waves.
Cutting efficiency of instruments with different movements: a comparative study.
Tocci, Luigi; Plotino, Gianluca; Al-Sudani, Dina; Rubini, Alessio Giansiracusa; Sannino, Gianpaolo; Piasecki, Lucila; Putortì, Ermanno; Testarelli, Luca; Gambarini, Gianluca
2015-01-01
The aim of the present study was to evaluate the cutting efficiency of two new reciprocating instruments, Twisted File Adaptive and WaveOne Primary. 10 new Twisted File Adaptive (TF Adaptive) (SybronEndo, Glendora, CA, USA) and 10 new WaveOne Primary files (Dentsply Maillefer, Ballaigues, Switzerland) were activated using a torque-controlled motor, respectively TFA motor (SybronEndo, Glendora, CA, USA) and Silver motor (VDW, Munich, Germany). The device used for the cutting test consisted on a mainframe to which a mobile plastic support for the hand-piece is connected and a stainless-steel block containing a Plexiglas block against which the cutting efficiency of the instruments was tested. The length of the block cut in 1 minute was measured in a computerized program with a precision of 0.1 mm. Mean and standard deviations of each group were calculated and data were statistically analyzed with one-way ANOVA and Bonferroni t test (P < 0.05). TF Adaptive displayed significantly greater maximum penetration depth than WaveOne Primary (P < 0.05). In fact, TF Adaptive instruments (Group 1) cut the Plexiglas block to a mean depth of 8.7 (SD 0.5) mm, while WaveOne Primary instruments cut the Plexiglas block to a mean depth of 6.4 (SD 0.3) mm. Twisted File Adaptive instruments demonstrated statistically higher cutting efficiency than WaveOne instruments.
Cutting Efficiency of Instruments with Different Movements: a Comparative Study
Plotino, Gianluca; Al-Sudani, Dina; Rubini, Alessio Giansiracusa; Sannino, Gianpaolo; Piasecki, Lucila; Putortì, Ermanno; Testarelli, Luca; Gambarini, Gianluca
2015-01-01
ABSTRACT Objectives The aim of the present study was to evaluate the cutting efficiency of two new reciprocating instruments, Twisted File Adaptive and WaveOne Primary. Material and Methods 10 new Twisted File Adaptive (TF Adaptive) (SybronEndo, Glendora, CA, USA) and 10 new WaveOne Primary files (Dentsply Maillefer, Ballaigues, Switzerland) were activated using a torque-controlled motor, respectively TFA motor (SybronEndo, Glendora, CA, USA) and Silver motor (VDW, Munich, Germany). The device used for the cutting test consisted on a mainframe to which a mobile plastic support for the hand-piece is connected and a stainless-steel block containing a Plexiglas block against which the cutting efficiency of the instruments was tested. The length of the block cut in 1 minute was measured in a computerized program with a precision of 0.1 mm. Mean and standard deviations of each group were calculated and data were statistically analyzed with one-way ANOVA and Bonferroni t test (P < 0.05). Results TF Adaptive displayed significantly greater maximum penetration depth than WaveOne Primary (P < 0.05). In fact, TF Adaptive instruments (Group 1) cut the Plexiglas block to a mean depth of 8.7 (SD 0.5) mm, while WaveOne Primary instruments cut the Plexiglas block to a mean depth of 6.4 (SD 0.3) mm. Conclusions Twisted File Adaptive instruments demonstrated statistically higher cutting efficiency than WaveOne instruments. PMID:25937877
NASA Astrophysics Data System (ADS)
Cherdantsev, Andrey; Hann, David; Azzopardi, Barry
2013-11-01
High-speed LIF-technique is applied to study gas-sheared liquid film in horizontal rectangular duct with 161 mm width. Instantaneous distributions of film thickness resolved in both longitudinal and transverse coordinates were obtained with a frequency of 10 kHz and spatial resolution from 0.125 mm to 0.04 mm. Processes of generation of fast and slow ripples by disturbance waves are the same as described in literature for downwards annular pipe flow. Disturbance waves are often localized by transverse coordinate and may have curved or slanted fronts. Fast ripples, covering disturbance waves, are typically horseshoe-shaped and placed in staggered order. Their characteristic transverse size is of order 1 cm and it decreases with gas velocity. Entrainment of liquid from film surface can also be visualized. Mechanisms of ripple disruption, known as ``bag break-up'' and ``ligament break-up,'' were observed. Both mechanisms may occur on the same disturbance waves. Various scenarios of droplet deposition on the liquid film are observed, including the impact, slow sinking and bouncing, characterized by different outcome of secondary droplets or entrapped bubbles. Number and size of bubbles increase greatly inside the disturbance waves. Both quantities increase with gas and liquid flow rates. EPSRC Programme Grant MEMPHIS (EP/K003976/1), and Roll-Royce UTC (Nottingham, for access to flow facility).
High-Intensity Interval Cycling Exercise on Wave Reflection and Pulse Wave Velocity.
Kingsley, J Derek; Tai, Yu Lun; Vaughan, Jeremiah A; Mayo, Xián
2017-05-01
Kingsley, JD, Tai, YL, Vaughan, J, and Mayo, X. High-intensity interval cycling exercise on wave reflection and pulse wave velocity. J Strength Cond Res 31(5): 1313-1320, 2017-The purpose of this study was to assess the effects of high-intensity exercise on wave reflection and aortic stiffness. Nine young, healthy men (mean ± SD: age: 22 ± 2 years) participated in the study. The high-intensity interval cycling exercise consisted of 3 sets of Wingate Anaerobic Tests (WATs) with 7.5% of bodyweight as resistance and 2 minutes of rest between each set. Measurements were taken at rest and 1 minute after completion of the WATs. Brachial and aortic blood pressures, as well as wave reflection characteristics, were measured through pulse wave analysis. Aortic stiffness was assessed through carotid-femoral pulse wave velocity (cfPWV). A repeated-measures analysis of variance was used to investigate the effects of the WATs on blood pressure and vascular function across time. There was no change in brachial or aortic systolic pressure from rest to recovery. There was a significant (p ≤ 0.05) decrease in brachial diastolic pressure (rest: 73 ± 6 mm Hg; recovery: 67 ± 9 mm Hg) and aortic diastolic pressure (rest: 75 ± 6 mm Hg; recovery: 70 ± 9 mm Hg) from rest to recovery. In addition, there was no significant change in the augmentation index (rest: 111.4 ± 6.5%; recovery: 109.8 ± 5.8%, p = 0.65) from rest to recovery. However, there was a significant (p ≤ 0.05) increase in the augmentation index normalized at 75 b·min (rest: 3.29 ± 9.82; recovery 21.21 ± 10.87) during recovery compared with rest. There was no change in cfPWV (rest: 5.3 ± 0.8 m·s; recovery: 5.7 ± 0.5m·s; p = 0.09) in response to the WAT. These data demonstrate that high-intensity interval cycling exercise with short rest periods has a nonsignificant effect on vascular function.
Dhingra, Annil; Ruhal, Nidhi; Miglani, Anjali
2015-04-01
Successful endodontic therapy depends on many factor, one of the most important step in any root canal treatment is root canal preparation. In addition, respecting the original shape of the canal is of the same importance; otherwise, canal aberrations such as transportation will be created. The purpose of this study is to compare and evaluate Reciprocating WaveOne ,Reciproc and Rotary Oneshape Single File Instrumentation System On Cervical Dentin Thickness, Cross Sectional Area and Canal Transportation on First Mandibular Molar Using Cone Beam Computed Tomography. Sixty Mandibular First Molars extracted due to periodontal reason was collected from the Department of Oral and Maxillofacial. Teeth were prepared using one rotary and two reciprocating single file system. Teeth were divided into 3 groups 20 teeth in each group. Pre instrumentation and Post instrumentation scans was done and evaluated for three parameters Canal Transportation, Cervical Dentinal Thickness, Cross-sectional Area. Results were analysed statistically using ANOVA, Post-Hoc Tukey analysis. The change in cross-sectional area after filing showed significant difference at 0mm, 1mm, 2mm and 7mm (p<0.001, p =0.006, 0.004 & <0.001 respectively). There was significant difference between wave one and oneshape; oneshape and reciproc at 0mm, 1mm, 2mm & 7mm (p-values for waveone and Oneshape <0.001, 0.022, 0.011 & <0.001 resp. and for oneshape and reciproc < 0.001, p= 0.011, p=0.008 & <0.001). On assessing the transportation of the three file system over a distance of 7 mm (starting from 0mm and then evaluation at 1mm, 2mm, 3mm, 5mm and 7mm), the results showed a significant difference among the file systems at various lengths (p= 0.014, 0.046, 0.004, 0.028, 0.005 & 0.029 respectively). Mean value of cervical dentinal removal is maximum at all the levels for oneshape and minimum for waveone showing the better quality of waveone and reciproc over oneshape file system. Significant difference was found at 9mm, 11mm and 12mm between all the three file systems (p<0.001,< 0.001, <0.001). It was concluded that reciprocating motion is better than rotary motion in all the three parameters Canal Transportation, Cross-sectional Area, Cervical Dentinal Thickness.
Using Kinect to Measure Wave Spectrum
NASA Astrophysics Data System (ADS)
Fong, J.; Loose, B.; Lovely, A.
2012-12-01
Gas exchange at the air-sea interface is enhanced by aqueous turbulence generated by capillary-gravity waves, affecting the absorption of atmospheric carbon dioxide by the ocean. The mean squared wave slope
NASA Astrophysics Data System (ADS)
Ahrens, Thomas J.; Boslough, Mark B.; Ginn, Warren G.; Vassiliou, Mario S.; Lange, Manfred A.; Watt, J. Peter; Kondo, Ken-Ichi; Svendsen, Robert F.; Rigden, Sally M.; Stolper, Edward M.
1982-04-01
Shock wave and experimental impact phenomena research on geological and planetary materials is being carried out using two propellant (18 and 40 mm) guns (up to 2.5 km/sec) and a two-stage light gas gun (up to 7 km/sec). Equation of state measurements on samples initially at room temperture and at low and high temperatures are being conducted using the 40 mm propellant apparatus in conjunction with Helmholtz coils, and radiative detectors and, in the case of the light gas gun, with streak cameras. The 18 mm propellant gun is used for recovery experiments on minerals, impact on cryogenic targets, and radiative post-shock temperature measurements.
A Millimeter-Wave Digital Link for Wireless MRI
Aggarwal, Kamal; Joshi, Kiran R.; Rajavi, Yashar; Taghivand, Mazhareddin; Pauly, John M.; Poon, Ada S. Y.; Scott, Greig
2017-01-01
A millimeter (mm) wave radio is presented in this work to support wireless MRI data transmission. High path loss and availability of wide bandwidth make mm-waves an ideal candidate for short range, high data rata communication required for wireless MRI. The proposed system uses a custom designed integrated chip (IC) mm-wave radio with 60 GHz as radio frequency carrier. In this work, we assess performance in a 1.5 T MRI field, with the addition of optical links between the console room and magnet. The system uses ON-OFF keying (OOK) modulation for data transmission and supports data rates from 200 Mb/s to 2.5 Gb/s for distances up-to 65 cm. The presence of highly directional, linearly polarized, on-chip dipole antennas on the mm-wave radio along with the time division multiplexing (TDM) circuitry allows multiple wireless links to be created simultaneously with minimal inter-channel interference. This leads to a highly scalable solution for wireless MRI. PMID:27810803
A Millimeter-Wave Digital Link for Wireless MRI.
Aggarwal, Kamal; Joshi, Kiran R; Rajavi, Yashar; Taghivand, Mazhareddin; Pauly, John M; Poon, Ada S Y; Scott, Greig
2017-02-01
A millimeter (mm) wave radio is presented in this work to support wireless MRI data transmission. High path loss and availability of wide bandwidth make mm-waves an ideal candidate for short range, high data rata communication required for wireless MRI. The proposed system uses a custom designed integrated chip (IC) mm-wave radio with 60 GHz as radio frequency carrier. In this work, we assess performance in a 1.5 T MRI field, with the addition of optical links between the console room and magnet. The system uses ON-OFF keying (OOK) modulation for data transmission and supports data rates from 200 Mb/s to 2.5 Gb/s for distances up-to 65 cm. The presence of highly directional, linearly polarized, on-chip dipole antennas on the mm-wave radio along with the time division multiplexing (TDM) circuitry allows multiple wireless links to be created simultaneously with minimal inter-channel interference. This leads to a highly scalable solution for wireless MRI.
Intracompartmental pressure as a predictor of intratesticular blood flow: a rat model.
Watson, Matthew J; Bartkowski, Donald P; Nelson, Nathan C
2015-06-01
We identified an intratesticular pressure at which vascular flow would cease in a testicular compartment syndrome model, defining a critical vascular stop flow pressure. A total of 52 male Sprague Dawley® rats were used for the study. The testicle of each rat was delivered from the scrotum and size measurements were taken. An intracompartment pressure monitor needle was inserted into the testis to record basal intratesticular pressure. The monitor needle remained in the testicle for the duration of the procedure. Vascular flow within the testis was measured using a variable frequency linear ultrasound transducer with color flow and pulse wave Doppler modalities. Saline was infused through the compartment monitor in 5 mm Hg increments via a pressure infusion pump. Following each 5 mm Hg increase intratesticular vascular blood flow and velocities were recorded using color flow and pulse wave, respectively. Data collection proceeded until color flow images indicated a complete absence of flow within the testis. Using a paired t-test (p <0.0001), mean color flow stop flow pressure was 52.17 mm Hg (95% CI 49.57-54.77) and pulse wave stop flow pressure was 36.34 mm Hg (95% CI 33.90-38.77). Regression analysis of pulse wave vs color flow showed a slope of 0.6960 ± 0.09112, a y-intercept of 0.02427 ± 4.824 and an x-intercept of -0.03486. This is the first known study to characterize a stop flow pressure within the testicular parenchyma resulting from an increased intracompartmental pressure. Due to probe sensitivity limitations, color flow appears to provide the most precise mean pressure of occlusion of 52.17 mm Hg. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Dielectric Waveguides Splitter and Hybrid/Isolator for Bidirectional Link
NASA Technical Reports Server (NTRS)
Tang, Adrian Joseph (Inventor); Chattopadhyay, Goutam (Inventor); Chahat, Nacer E. (Inventor); Decrossas, Emmanuel (Inventor)
2016-01-01
A system, method, device, and apparatus provide a dielectric waveguide splitter/bi-directional link. A dielectric substrate fabricated into a first Y-junction waveguide with a first port splitting into a first branch leading to a second port and a second branch leading to a third port. An angle between the first branch and the second branch is below ninety degrees (90.degree.). The dielectric waveguide splitter enables millimeter-wave (mmWave) transmission between the first port and the second port while reducing feedback of the mmWave between the second and third port. Two Y-junction waveguides may be fabricated back-to-back to provide simultaneous bidirectional mmWave transmission at a single frequency.
Architectural Considerations of Fiber-Radio Millimeter-Wave Wireless Access Systems
NASA Astrophysics Data System (ADS)
Kitayama, Ken-Ichi
The architecture of fiber-radio mm-wave wireless access systems critically depends upon the optical mm-wave generation and transport techniques. Four optical mm-wave generation and transport techniques: 1) optical self-heterodyning, 2) external modulation, 3) up- and downconversion, and 4) optical transceiver, will be assessed. From the technical viewpoints, their advantages and disadvantages are discussed. The economical assessment, focusing on the cost of a base station BS ( ), will suggest that the optical transceiver looks the most promising in the long run, but in the near future, however, the external modulation will be cost-effective. The experimental results of 60 GHz testbeds using the external modulation will support the conclusion.
VizieR Online Data Catalog: Cyanoacetylene (HC3N) infrared spectrum (Bizzocchi+,
NASA Astrophysics Data System (ADS)
Bizzocchi, L.; Tamassia, F.; Laas, J.; Giuliano, B. M.; Degli Esposti, C.; Dore, L.; Melosso, M.; Cane, E.; Pietropolli Charmet, A.; Muller, H. S. P.; Spahn, H.; Belloche, A.; Caselli, P.; Menten, K. M.; Garrod, R. T.
2018-01-01
A substantial amount of new spectroscopic data of HC3N was col in four laboratories located in Bologna, Italy and in Cologne and Munich, Germany. The infrared spectra in the 450-1100cm-1 range were recorded in Bologna using a Bomem DA3.002 Fourier-transform spectrometer. The resolution was generally 0.004cm-1. New mm-wave spectra in selected frequency intervals between 80 and 400GHz were observed in Bologna using a frequency-modulation (FM) mm-wave spectrometer whose details are reported elsewhere (see, e.g., Bizzocchi+ 2016, J/ApJ/820/L26). Further measurements of the sub-mm-wave spectrum of HC3N in the 200-690GHz frequency range were carried out at the Center for Astrochemical Studies (MPE Garching). The measurements performed in Cologne were carried out with leftover samples from previous studies (Yamada+ 1995ZNatA..50.1179Y ; Thorwirth+ 2000JMoSp.204..133T). Further measurements were made using the Cologne Terahertz Spectrometer. See section 2 for further explanations. (2 data files).
Three-dimensional mid-air acoustic manipulation by ultrasonic phased arrays.
Ochiai, Yoichi; Hoshi, Takayuki; Rekimoto, Jun
2014-01-01
The essence of levitation technology is the countervailing of gravity. It is known that an ultrasound standing wave is capable of suspending small particles at its sound pressure nodes. The acoustic axis of the ultrasound beam in conventional studies was parallel to the gravitational force, and the levitated objects were manipulated along the fixed axis (i.e. one-dimensionally) by controlling the phases or frequencies of bolted Langevin-type transducers. In the present study, we considered extended acoustic manipulation whereby millimetre-sized particles were levitated and moved three-dimensionally by localised ultrasonic standing waves, which were generated by ultrasonic phased arrays. Our manipulation system has two original features. One is the direction of the ultrasound beam, which is arbitrary because the force acting toward its centre is also utilised. The other is the manipulation principle by which a localised standing wave is generated at an arbitrary position and moved three-dimensionally by opposed and ultrasonic phased arrays. We experimentally confirmed that expanded-polystyrene particles of 0.6 mm, 1 mm, and 2 mm in diameter could be manipulated by our proposed method.
Three-Dimensional Mid-Air Acoustic Manipulation by Ultrasonic Phased Arrays
Ochiai, Yoichi; Hoshi, Takayuki; Rekimoto, Jun
2014-01-01
The essence of levitation technology is the countervailing of gravity. It is known that an ultrasound standing wave is capable of suspending small particles at its sound pressure nodes. The acoustic axis of the ultrasound beam in conventional studies was parallel to the gravitational force, and the levitated objects were manipulated along the fixed axis (i.e. one-dimensionally) by controlling the phases or frequencies of bolted Langevin-type transducers. In the present study, we considered extended acoustic manipulation whereby millimetre-sized particles were levitated and moved three-dimensionally by localised ultrasonic standing waves, which were generated by ultrasonic phased arrays. Our manipulation system has two original features. One is the direction of the ultrasound beam, which is arbitrary because the force acting toward its centre is also utilised. The other is the manipulation principle by which a localised standing wave is generated at an arbitrary position and moved three-dimensionally by opposed and ultrasonic phased arrays. We experimentally confirmed that expanded-polystyrene particles of 0.6 mm, 1 mm, and 2 mm in diameter could be manipulated by our proposed method. PMID:24849371
Aortic stiffness and the balance between cardiac oxygen supply and demand: the Rotterdam Study.
Guelen, Ilja; Mattace-Raso, Francesco Us; van Popele, Nicole M; Westerhof, Berend E; Hofman, Albert; Witteman, Jacqueline Cm; Bos, Willem Jan W
2008-06-01
Aortic stiffness is an independent predictor of cardiovascular morbidity and mortality. We investigated whether aortic stiffness, estimated as aortic pulse wave velocity, is associated with decreased perfusion pressure estimated as the cardiac oxygen supply potential. Aortic stiffness and aortic pressure waves, reconstructed from finger blood pressure waves, were obtained in 2490 older adults within the framework of the Rotterdam Study, a large population-based study. Cardiac oxygen supply and demand were estimated using pulse wave analysis techniques, and related to aortic stiffness by linear regression analyses after adjustment for age, sex, mean arterial pressure and heart rate. Cardiac oxygen demand, estimated as the Systolic Pressure Time Index and the Rate Pressure Product, increased with increasing aortic stiffness [0.27 mmHg s (95% confidence interval: 0.21; 0.34)] and [42.2 mmHg/min (95% confidence interval: 34.1; 50.3)], respectively. Cardiac oxygen supply potential estimated as the Diastolic Pressure Time Index decreased [-0.70 mmHg s (95% confidence interval: -0.86; -0.54)] with aortic stiffening. Accordingly, the supply/demand ratio Diastolic Pressure Time Index/Systolic Pressure Time Index -1.11 (95% confidence interval: -0.14; -0.009) decreased with increasing aortic stiffness. Aortic stiffness is associated with estimates of increased cardiac oxygen demand and a decreased cardiac oxygen supply potential. These results may offer additional explanation for the relation between aortic stiffness and cardiovascular morbidity and mortality.
Bakry, Ahmed
2014-01-01
This paper presents modeling and simulation on the characteristics of semiconductor laser modulated within a strong optical feedback (OFB-)induced photon-photon resonance over a passband of millimeter (mm) frequencies. Continuous wave (CW) operation of the laser under strong OFB is required to achieve the photon-photon resonance in the mm-wave band. The simulated time-domain characteristics of modulation include the waveforms of the intensity and frequency chirp as well as the associated distortions of the modulated mm-wave signal. The frequency domain characteristics include the intensity modulation (IM) and frequency modulation (FM) responses in addition to the associated relative intensity noise (RIN). The signal characteristics under modulations with both single and two mm-frequencies are considered. The harmonic distortion and the third order intermodulation distortion (IMD3) are examined and the spurious free dynamic range (SFDR) is calculated. PMID:25383381
Evidence for Highly Inhomogeneous mm-Wave Sources During the Impulsive Flare of May 9, 1991
NASA Technical Reports Server (NTRS)
Hermann, R.; Magun, A.; Kaufmann, P.; Correia, E.; Costa, J. E. R.; Machado, M. E.; Fishman, G.
1997-01-01
In this paper multiwavelength observations of an impulsive flare of May 9, 1991 are presented. This event was observed with the 48 GHz multibeam focal array used at the Itapetinga radio telescope, the microwave patrol telescopes at Bem and the BATSE high time resolution hard X-ray spectrometer on board CGRO. While spatially unresolved low sensitivity observations show two major impulsive peaks, the mm-wave observations with the ability of spatially high resolved tracking of the emission centroids suggest a primarily bipolar source configuration. For the first time two mm-wave sources with a spacing below the HPBW could be separated with the multibeam technique. The general features of the observations are explained as emission of partially trapped electrons. Furthermore we present evidence for highly inhomogeneous substructures within one of the two mm-wave sources for which the positional scatter of the emission center, within 2s, is less than 2".
NASA Astrophysics Data System (ADS)
Lee, Han Soo; Yamashita, Takao; Hsu, John R.-C.; Ding, Fei
2013-01-01
In August 2009, Typhoon Morakot caused massive flooding and devastating mudslides in the southern Taiwan triggered by extremely heavy rainfall (2777 mm in 4 days) which occurred during its passage. It was one of the deadliest typhoons that have ever attacked Taiwan in recent years. In this study, numerical simulations are performed for the storm surge and ocean surface waves, together with dynamic meteorological fields such as wind, pressure and precipitation induced by Typhoon Morakot, using an atmosphere-waves-ocean integrated modelling system. The wave-induced dissipation stress from breaking waves, whitecapping and depth-induced wave breaking, is parameterized and included in the wave-current interaction process, in addition to its influence on the storm surge level in shallow water along the coast of Taiwan. The simulated wind and pressure field captures the characteristics of the observed meteorological field. The spatial distribution of the accumulated rainfall within 4 days, from 00:00 UTC 6 August to 00:00 UTC 10 August 2009, shows similar patterns as the observed values. The 4-day accumulated rainfall of 2777 mm at the A-Li Shan mountain weather station for the same period depicted a high correlation with the observed value of 2780 mm/4 days. The effects of wave-induced dissipation stress in the wave-current interaction resulted in increased surge heights on the relatively shallow western coast of Taiwan, where the bottom slope of the bathymetry ranges from mild to moderate. The results also show that wave-breaking has to be considered for accurate storm surge prediction along the east coast of Taiwan over the narrow bank of surf zone with a high horizontal resolution of the model domain.
NASA Astrophysics Data System (ADS)
Crossingham, Grant James
This thesis is concerned with the design of a new ocean going instrument to measure the local sea surface profile. The motivation behind this project was the need to investigate oceanographic features that have been observed using imaging radar aboard aircraft and satellites. The measurements made with this instrument will further the understanding of the processes involved in radar backscatter from the ocean surface and will enable further analysis of ocean phenomena detected using imaging radars. With an improved understanding of these processes it will be possible to analyse quantitatively satellite images generated from around the globe. This will allow global environmental monitoring which could lead to improved weather forecasting, pollution control such as oil slick monitoring and surface and subsurface operations. It is believed that radar signals having a wavelength of 10 to 300mm are backscattered from waves on the ocean surface of similar length. Earlier attempts to measure waves including those designed to measure millimetric waves are critically reviewed and an account of the evolution of the design of a new instrument to measure these small waves is presented. This new instrument has been tested in the laboratory, which has demonstrated that a repeatable wave slope measurement accuracy of +/-0.56° has been achieved in static tests. Dynamic tests made using a wave tank have generated a wave slope profile, clearly showing 10mm wavelengths present on the surface. The new Digital Slopemeter is designed to measure the small-scale sea surface roughness for wavelengths in the range 10mm to 224mm. This instrument uses two grids of wavelength shifting fibres to digitally record the slope of a refracted laser beam. The laser beam is rapidly scanned over the sea surface to ensure that the profile of the surface is effectively stationary over a length of 224mm. The wave slope is sampled at 3.5mm intervals along each scan, allowing 7mm wavelengths to be resolved. This efficient measurement of the sea surface roughness enables a real-time display of the data collected. The design of the instrument permits it to be deployed from the bow of a research vessel in moderate seas. This instrument is therefore simple and flexible to deploy.
Submillimeter heterodyne spectroscopy of star forming regions
NASA Astrophysics Data System (ADS)
Groppi, Christopher Emil
The sub-mm wave portion of the electromagnetic spectrum is on the frontier of both scientific and technical research in astrophysics. Being a relatively young field, scientific advancement is driven by advancements in detector technology. In this thesis, I discuss the design, construction, testing and deployment of two sub-mm wave heterodyne array receivers. Polestar is a 4 pixel (2 x 2) heterodyne array built for operation in the 810 GHz atmospheric window. It is in operation at the AST/RO telescope at the South Pole. This receiver has increased imaging speed in this band at AST/RO by a factor of ˜20 compared to previous receiver systems. DesertStar is a 7 pixel, hexagonally close packed heterodyne array receiver built to operate in the 345 GHz atmospheric window at the Heinrich Hertz Telescope in Arizona. This system will be a facility instrument at the telescope, and will increase mapping speed over the existing dual polarization single beam receiver at the telescope now by a factor of ˜16. Both these receiver systems enable scientific projects requiring large area imaging that were previously impossible. I also discuss two scientific applications of sub-mm wave receiver systems. We have used multiple telescopes to observe several mm, sub-mm transitions and continuum emission towards the R CrA molecular cloud core. Originally thought to be associated with high mass star formation, we find that the driving source behind the mm-wave emission is a low mass protostar. The close proximity of R CrA allows us to achieve high spatial resolution even with single dish mm-wave and sub-mm wave telescopes. With this resolution, we are able to disentangle the effects of infall, rotation and outflow motions. We also use vibrationally excited HCN emission to probe the protostellar accretion disk in a sample of nearby high and low mass protostars of varying ages. While these observations are difficult with single dish telescopes, we show the promise of the technique, and report results on 4 sources.
Pawar, Ajinkya M; Thakur, Bhagyashree; Metzger, Zvi; Kfir, Anda; Pawar, Mansing
2016-01-01
Aim: The current ex vivo study compared the efficacy of removing root fillings using ProTaper retreatment files followed by either WaveOne reciprocating file or the Self-Adjusting File (SAF). Materials and Methods: Forty maxillary canines with single oval root canal were selected and sectioned to obtain 18-mm root segments. The root canals were instrumented with WaveOne primary files, followed by obturation using warm lateral compaction, and the sealer was allowed to fully set. The teeth were then divided into two equal groups (N = 20). Initial removal of the bulk of root filling material was performed with ProTaper retreatment files, followed by either WaveOne files (Group 1) or SAF (Group 2). Endosolv R was used as a gutta-percha softener. Preoperative and postoperative high-resolution cone-beam computed tomography (CBCT) was used to measure the volume of the root filling residue that was left after the procedure. Statistical analysis was performed using t-test. Results: The mean volume of root filling residue in Group 1 was 9.4 (±0.5) mm3, whereas in Group 2 the residue volume was 2.6 (±0.4) mm3, (P < 0.001; t-test). Conclusions: When SAF was used after ProTaper retreatment files, significantly less root filling residue was left in the canals compared to when WaveOne was used. PMID:26957798
Influence of Aggregate Gradation on the Longitudinal Wave Velocity Changes in Unloaded Concrete
NASA Astrophysics Data System (ADS)
Teodorczyk, Michał
2017-10-01
Diagnosis is an important factor in the assessment of structural and operational condition of a concrete structure. Among diagnostic methods, non-destructive testing methods play a special role. Acoustic emission evaluation based on the identification and location of destructive processes is one of such methods. The 3D location of AE events and moment tensor of fracture analysis are calculated by longitudinal wave velocity. Therefore, determining the velocity of longitudinal wave of concrete and the impact of the material and destructive factors are of essential importance. This paper reports the investigation of the effect of aggregate gradation on the change in wave velocity of unloaded concrete. The investigation was carried out on six 150 x 150 x 600 mm elements. Three elements contained aggregate fraction 8/16 mm and the other three were made with aggregate fraction 2/16 mm. Two acoustic emission sensors were used on the surface of the elements, and the wave was generated by the Hsu - Nielsen source. Longitudinal wave velocities for each group of elements were calculated and statistical test of significance was used for the comparison of two means. The results of the test indicated a substantial effect of the aggregate grain size on the change in longitudinal wave velocity. The average wave velocity in the concrete containing 8/16 mm fraction was 4672 m/s. In the concrete with 2/16 mm fraction, the velocity decreased to 4373 m/s. The velocity of the wave decreases at larger quantities of aggregate. The propagating longitudinal wave encounters more aggregate grains on its way and is reflected, also from air voids, multiple times and so its velocity is noticeably lower in the concrete with the 2/16 fraction. Thus, to be able to accurately locate AE events and analyse moment tensor during concrete structure testing, the aggregate grain size used in the concrete should be taken into account.
Multi-sensor millimeter-wave system for hidden objects detection by non-collaborative screening
NASA Astrophysics Data System (ADS)
Zouaoui, Rhalem; Czarny, Romain; Diaz, Frédéric; Khy, Antoine; Lamarque, Thierry
2011-05-01
In this work, we present the development of a multi-sensor system for the detection of objects concealed under clothes using passive and active millimeter-wave (mmW) technologies. This study concerns both the optimization of a commercial passive mmW imager at 94 GHz using a phase mask and the development of an active mmW detector at 77 GHz based on synthetic aperture radar (SAR). A first wide-field inspection is done by the passive imager while the person is walking. If a suspicious area is detected, the active imager is switched-on and focused on this area in order to obtain more accurate data (shape of the object, nature of the material ...).
Concentrated energy addition for active drag reduction in hypersonic flow regime
NASA Astrophysics Data System (ADS)
Ashwin Ganesh, M.; John, Bibin
2018-01-01
Numerical optimization of hypersonic drag reduction technique based on concentrated energy addition is presented in this study. A reduction in wave drag is realized through concentrated energy addition in the hypersonic flowfield upstream of the blunt body. For the exhaustive optimization presented in this study, an in-house high precision inviscid flow solver has been developed. Studies focused on the identification of "optimum energy addition location" have revealed the existence of multiple minimum drag points. The wave drag coefficient is observed to drop from 0.85 to 0.45 when 50 Watts of energy is added to an energy bubble of 1 mm radius located at 74.7 mm upstream of the stagnation point. A direct proportionality has been identified between energy bubble size and wave drag coefficient. Dependence of drag coefficient on the upstream added energy magnitude is also revealed. Of the observed multiple minimum drag points, the energy deposition point (EDP) that offers minimum wave drag just after a sharp drop in drag is proposed as the most optimum energy addition location.
Cai, Zhiyu; Falkensammer, Frank; Andrukhov, Oleh; Chen, Jiang; Mittermayr, Rainer; Rausch-Fan, Xiaohui
2016-01-01
Background Extracorporeal shock wave therapy (ESWT) can modulate cell behavior through mechanical information transduction. Human periodontal ligament fibroblasts (hPDLF) are sensible to mechanical stimulus and can express pro-inflammatory molecules in response. The aim of this study was to evaluate the impacts of shock waves on interleukin-6 (IL-6), interleukin-8 (IL-8), monocyte chemotactic protein 1 (MCP-1), and tumor necrosis factor-alpha (TNF-α) expression by hPDLF. Material/Methods After being treated by shock waves with different parameters (100–500 times, 0.05–0.19 mJ/mm2), cell viability was tested using CCK-8. IL-6, IL-8, MCP-1, and TNF-α gene expression was analyzed by quantitative real-time polymerase chain reaction (qRT-PCR) and IL-6 and IL-8 protein was measured by enzyme-linked immunosorbent assay (ELISA) at different time points. Results Shock waves with the parameters used in this study had no significant effects on the viability of hPDLF. A statistical inhibition of IL-6, IL-8, MCP-1, and TNF-α expression during the first few hours was observed (P<0.05). Expression of IL-8 was significantly elevated in the group receiving the most pulses of shock wave (500 times) after 4 h (P<0.05). At 8 h and 24 h, all treated groups demonstrated significantly enhanced IL-6 expression (P<0.05). TNF-α expression in the groups receiving more shock pulses (300, 500 times) or the highest energy shock treatment (0.19 mJ/mm2) was statistically decreased (P<0.05) at 24 h. Conclusions Under the condition of this study, a shock wave with energy density no higher than 0.19 mJ/mm2 and pulses no more than 500 times elicited no negative effects on cell viability of hPDLF. After a uniform initial inhibition impact on expression of inflammatory mediators, a shock wave could cause dose-related up-regulation of IL-6 and IL-8 and down-regulation of TNF-α. PMID:26994898
Detonation propagation in a high loss configuration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jackson, Scott I; Shepherd, Joseph E
2009-01-01
This work presents an experimental study of detonation wave propagation in tubes with inner diameters (ID) comparable to the mixture cell size. Propane-oxygen mixtures were used in two test section tubes with inner diameters of 1.27 mm and 6.35 mm. For both test sections, the initial pressure of stoichiometric mixtures was varied to determine the effect on detonation propagation. For the 6.35 mm tube, the equivalence ratio {phi} (where the mixture was {phi} C{sub 3}H{sub 8} + 50{sub 2}) was also varied. Detonations were found to propagate in mixtures with cell sizes as large as five times the diameter ofmore » the tube. However, under these conditions, significant losses were observed, resulting in wave propagation velocities as slow as 40% of the CJ velocity U{sub CJ}. A review of relevant literature is presented, followed by experimental details and data. Observed velocity deficits are predicted using models that account for boundary layer growth inside detonation waves.« less
Observation of two-dimensional Faraday waves in extremely shallow depth.
Li, Xiaochen; Yu, Zhengyue; Liao, Shijun
2015-09-01
A family of two-dimensional Faraday waves in extremely shallow depth (1 mm to 2 mm) of absolute ethanol are observed experimentally using a Hele-Shaw cell that vibrates vertically. The same phenomena are not observed by means of water, ethanol solution, and silicone oil. These Faraday waves are quite different from the traditional ones. These phenomena are helpful to deepen and enrich our understandings about Faraday waves, and besides provide a challenging problem for computational fluid dynamics.
Millimeter wave radars raise weapon IQ
NASA Astrophysics Data System (ADS)
Lerner, E. J.
1985-02-01
The problems encountered by laser and IR homing devices for guided munitions may be tractable with warhead-mounted mm-wave radars. Operating at about 100 GHz and having several kilometers range, mm-wave radars see through darkness, fog, rain and smoke. The radar must be coupled with an analyzer that discerns moving and stationary targets and higher priority targets. The target lock-on can include shut-off of the transmitter and reception of naturally-generated mm-waves bouncing off the target when in the terminal phase of the flight. Monopulse transmitters have simplified the radar design, although mass production of finline small radar units has yet to be accomplished, particularly in combining GaAs, ferrites and other materials on one monolithic chip.
Lamb Wave Propagation in a Restricted Geometry Composite PI-Joint Specimen (Preprint)
2011-11-01
adhesive, and were located along the length and height of the specimen as depicted in Figure 3. The sensors were 6.35 mm round disks of PZT , with a...in both cases for R1, R2, and R3. 3D Finite Element Model Geometry 200mm length 50mm width 140mm height x z y PZT Actuation Sensor...health monitoring using scanning laser vibrometry: III. Lamb waves for fatigue crack detection”, Smart Mater. Struct., Vol. 14, No. 6, 2005. 16
A Novel Split-Waveguide Mount Design For MM and SubMM wave frequency multipliers and Harmonic Mixers
NASA Technical Reports Server (NTRS)
Raisanen, Anti V.; Choudhury, Debabani; Dengler, Robert J.; Oswald, John E.; Siegel, Peter H.
1993-01-01
A novel split-waveguide mount for millimeter and submillimeter wave frequency multipliers and harmonic mixers is presented. It consists of only two pieces, block halves, which are mirror images of each other.
Zhang, Ruiliang; Qu, Yanchen; Zhao, Weijiang; Chen, Zhenlei
2017-03-20
A high energy, widely tunable Si-prism-array coupled terahertz-wave parametric oscillator (TPO) has been demonstrated by using a deformed pump. The deformed pump is cut from a beam spot of 2 mm in diameter by a 1-mm-wide slit. In comparison with a small pump spot (1-mm diameter), the THz-wave coupling area for the deformed pump is increased without limitation to the low-frequency end of the tuning range. Besides, the crystal location is specially designed to eliminate the alteration of the output position of the pump during angle tuning, so the initially adjusted nearest pumped region to the THz-wave exit surface is maintained throughout the tuning range. The tuning range is 0.58-2.5 THz for the deformed pump, while its low frequency end is limited at approximately 1.2 THz for the undeformed pump with 2 mm diameter. The highest THz-wave output of 2 μJ, which is 2.25 times as large as that from the pump of 1 mm in diameter, is obtained at 1.15 THz under 38 mJ (300 MW/cm2) pumping. The energy conversion efficiency is 5.3×10-5.
NASA Astrophysics Data System (ADS)
Paturi, Prem Kiran; Durvasula, P. S. L. Kameswari; S, Sai Shiva; Acrhem, University Of Hyderabad Team
2017-06-01
A two dimensional comparative study of Laser Ablative Shock Wave into the Aluminum target in the presence of Helium gas at different ambient pressures over a range of 690 - 105 Pa performed using FLASH hydrodynamic codes will be presented. The irradiation of Aluminum target (thickness 2 mm and radius 3 mm) with a 7 ns laser pulse of energy 175 mJ, spot size of 150 µm on the target surface at a wavelength of 532 nm at normal incidence is simulated. Helium gas enclosed in a chamber of height 3 mm and width 3 mm. The electron-ion inverse bremsstrahlung absorption coefficient is considered in the laser energy deposition process. The simulation was performed over a duration of 1 μs. It was observed that an ablative shock is launched into the Helium gas for the pressures of 0.5 atm and above. However, for pressure less than the 0.5 atm the plasma expanded into the He gas upto 12ns and after which due to pressure equilibration with the surroundings and plume splitting shock wave is launched in to Al. Authors acknowledge funding from DRDO, India.
Dhingra, Annil; Miglani, Anjali
2015-01-01
Background Successful endodontic therapy depends on many factor, one of the most important step in any root canal treatment is root canal preparation. In addition, respecting the original shape of the canal is of the same importance; otherwise, canal aberrations such as transportation will be created. Aim The purpose of this study is to compare and evaluate Reciprocating WaveOne ,Reciproc and Rotary Oneshape Single File Instrumentation System On Cervical Dentin Thickness, Cross Sectional Area and Canal Transportation on First Mandibular Molar Using Cone Beam Computed Tomography. Materials and Methods Sixty Mandibular First Molars extracted due to periodontal reason was collected from the Department of Oral and Maxillofacial. Teeth were prepared using one rotary and two reciprocating single file system. Teeth were divided into 3 groups 20 teeth in each group. Pre instrumentation and Post instrumentation scans was done and evaluated for three parameters Canal Transportation, Cervical Dentinal Thickness, Cross-sectional Area. Results were analysed statistically using ANOVA, Post-Hoc Tukey analysis. Results The change in cross-sectional area after filing showed significant difference at 0mm, 1mm, 2mm and 7mm (p<0.001, p =0.006, 0.004 & <0.001 respectively). There was significant difference between wave one and oneshape; oneshape and reciproc at 0mm, 1mm, 2mm & 7mm (p-values for waveone and Oneshape <0.001, 0.022, 0.011 & <0.001 resp. and for oneshape and reciproc < 0.001, p= 0.011, p=0.008 & <0.001). On assessing the transportation of the three file system over a distance of 7 mm (starting from 0mm and then evaluation at 1mm, 2mm, 3mm, 5mm and 7mm), the results showed a significant difference among the file systems at various lengths (p= 0.014, 0.046, 0.004, 0.028, 0.005 & 0.029 respectively). Mean value of cervical dentinal removal is maximum at all the levels for oneshape and minimum for waveone showing the better quality of waveone and reciproc over oneshape file system. Significant difference was found at 9mm, 11mm and 12mm between all the three file systems (p<0.001,< 0.001, <0.001). Conclusion It was concluded that reciprocating motion is better than rotary motion in all the three parameters Canal Transportation, Cross-sectional Area, Cervical Dentinal Thickness. PMID:26023639
Milatz, Florian; Ketelhut, Sascha; Ketelhut, Sascha; Ketelhut, Reinhard G
2015-07-01
Increased central pulse wave velocity is a major risk factor for cardiovascular disease. The favorable influence of exercise on arterial stiffness (AS) and blood pressure (BP) has been reported exclusively at rest. The present study investigated the influence of a single bout of acute cycling on AS and BP during recovery and, moreover, during cold pressor stress testing. 32 healthy men (33.7 ± 8 years, BMI 24 ± 2.5 kg/m²) performed a 60 minute endurance exercise on a bicycle ergometer (45 % VO2max). Before and after exercise aortic pulse wave velocity (aPWV) as well as central and peripheral BP were measured non-invasively at rest and at the end of a 2 minute cold pressor test (CPT). Even after 60 minutes of recovery aPWV (- 0.22 ± 0.3 m / sec) was significantly reduced (p < 0.01). Exercise decreased peripheral (- 8 ± 7 mmHg) and central (- 7 ± 8 mmHg) systolic BP as well as peripheral (- 3 ± 5 mmHg) and central (- 4 ± 7 mmHg) diastolic BP (p < 0.01). In comparison to measurements during CPT pre-exercise, there was a significant reduction in aPWV (- 0.19 ± 0.3 m / sec), peripheral (- 6 ± 10 mmHg) and central (- 5 ± 8 mmHg) systolic BP as well as peripheral (- 3 ± 6 mmHg) and central (- 3 ± 6 mmHg) diastolic BP during CPT after exercise (p < 0.01). The present study suggests that acute endurance exercise leads not only to decreased BP but even more reduces aPWV as a measure of AS even after 60 minutes of recovery. In particular, the investigation provides evidence that acute moderate-intensity exercise has a favorable effect on BP and aPWV during stress testing.
Badran, Yasser Ali; Abdelaziz, Alsayed Saad; Shehab, Mohamed Ahmed; Mohamed, Hazem Abdelsabour Dief; Emara, Absel-Aziz Ali; Elnabtity, Ali Mohamed Ali; Ghanem, Maged Mohammed; ELHelaly, Hesham Abdel Azim
2016-01-01
Objective: The objective was to determine the predicting success of shock wave lithotripsy (SWL) using a combination of computed tomography based metric parameters to improve the treatment plan. Patients and Methods: Consecutive 180 patients with symptomatic upper urinary tract calculi 20 mm or less were enrolled in our study underwent extracorporeal SWL were divided into two main groups, according to the stone size, Group A (92 patients with stone ≤10 mm) and Group B (88 patients with stone >10 mm). Both groups were evaluated, according to the skin to stone distance (SSD) and Hounsfield units (≤500, 500–1000 and >1000 HU). Results: Both groups were comparable in baseline data and stone characteristics. About 92.3% of Group A rendered stone-free, whereas 77.2% were stone-free in Group B (P = 0.001). Furthermore, in both group SWL success rates was a significantly higher for stones with lower attenuation <830 HU than with stones >830 HU (P < 0.034). SSD were statistically differences in SWL outcome (P < 0.02). Simultaneous consideration of three parameters stone size, stone attenuation value, and SSD; we found that stone-free rate (SFR) was 100% for stone attenuation value <830 HU for stone <10 mm or >10 mm but total number SWL sessions and shock waves required for the larger stone group were higher than in the smaller group (P < 0.01). Furthermore, SFR was 83.3% and 37.5% for stone <10 mm, mean HU >830, SSD 90 mm and SSD >120 mm, respectively. On the other hand, SFR was 52.6% and 28.57% for stone >10 mm, mean HU >830, SSD <90 mm and SSD >120 mm, respectively. Conclusion: Stone size, stone density (HU), and SSD is simple to calculate and can be reported by radiologists to applying combined score help to augment predictive power of SWL, reduce cost, and improving of treatment strategies. PMID:27141192
Tambe, Varsha Harshal; Nagmode, Pradnya Sunil; Abraham, Sathish; Patait, Mahendra; Lahoti, Pratik Vinod; Jaju, Neha
2014-01-01
Aim: The aim of the present study was to compare the canal transportation and centering ability of Rotary ProTaper, One Shape and Wave One systems using cone beam computed tomography (CBCT) in curved root canals to find better instrumentation technique for maintaining root canal geometry. Materials and Methods: Total 30 freshly extracted premolars having curved root canals with at least 10 degrees of curvature were divided into three groups of 10 teeth each. All teeth were scanned by CBCT to determine the root canal shape before instrumentation. In Group 1, the canals were prepared with Rotary ProTaper files, in Group 2 the canals were prepared with One Shape files and in Group 3 canals were prepared with Wave One files. After preparation, post-instrumentation scan was performed. Pre-instrumentation and post-instrumentation images were obtained at three levels, 3 mm apical, 3 mm coronal and 8 mm apical above the apical foramen were compared using CBCT software. Amount of transportation and centering ability were assessed. The three groups were statistically compared with analysis of variance and Tukey honestly significant. Results: All instruments maintained the original canal curvature with significant differences between the different files. Data suggested that Wave One files presented the best outcomes for both the variables evaluated. Wave One files caused lesser transportation and remained better centered in the canal than One Shape and Rotary ProTaper files. Conclusion: The canal preparation with Wave One files showed lesser transportation and better centering ability than One Shape and ProTaper. PMID:25506145
Analysis of Rayleigh-Lamb Modes in Soft-solids with Application to Surface Wave Elastography
NASA Astrophysics Data System (ADS)
Benech, Nicolás; Grinspan, Gustavo; Aguiar, Sofía; Brum, Javier; Negreira, Carlos; tanter, Mickäel; Gennisson, Jean-Luc
The goal of Surface Wave Elastography (SE) techniques is to estimate the shear elasticity of the sample by measuring the surface wave speed. In SE the thickness of the sample is often assumed to be infinite, in this way, the surface wave speed is directly linked to the sample's shear elasticity. However for many applications this assumption is not true. In this work, we study experimentally the Rayleigh-Lamb modes in soft solids of finite thickness to explore the optimal conditions for SWE. Experiments were carried out in three tissue mimicking phantoms of different thicknesses (10 mm, 20 mm and 60 mm) and same shear elasticity. The surface waves were generated at the surface of the phantom using piston attached to a mechanical vibrator. The central frequency of the excitation was varied between 60 Hz to 160 Hz. One component of the displacement field generated by the piston was measured at the surface and in the bulk of the sample trough a standard speckle tracking technique using a 256 element, 7.5 MHz central frequency linear array and an ultrasound ultrafast electronics. Finally, by measuring the phase velocity at each excitation frequency, velocity dispersion curves were obtained for each phantom. The results show that instead of a Rayleigh wave, zero order symmetric (S0) and antisymmetric (A0) Lamb modes are excited with this type of source. Moreover, in this study we show that due to the near field effects of the source, which are appreciable only in soft solids at low frequencies, both Lamb modes are separable in time and space. We show that while the Ao mode dominates close the source, the S0 mode dominates far away.
NASA Astrophysics Data System (ADS)
Hein, C. J.; Billy, J.; Robin, N.; FitzGerald, D.; Certain, R.
2017-12-01
The internal architecture of beach-ridge systems can provide insight into processes ongoing during its period of formation, such as changing relative sea-level (RSL). The paraglacial beach-ridge plain at Miquelon-Langlade (south of Newfoundland - NW Atlantic) is an example of a well-preserved regressive barrier. Initiation of this plain correlates with a decrease in the rate of RSL rise (from +4.4 mm/yr to 1.3 mm/yr) at around 3000 years ago. The combination of stratigraphic (ground-penetrating radar and sediment cores), topographic (RTK-GPS) and chronologic (optically stimulated luminescence, OSL) data provide a detailed understanding of the constructional history of the plain. The internal architecture of individual beach ridges are characterized by sigmoidal configurations with seaward-dipping (2.3-4.7°) beds. Field mapping data reveal the processes associated with development of individual ridges in relation to sea level elevation. First, wave-built facies (sand-and-gravel) are deposited as beach berms, likely by fair-weather waves, with their elevations controlled by sea level and the swash height of constructive waves. This is followed by the accretion of aeolian sand deposits (foredunes) on the previous relict ridge, and then colonization by pioneer grasses. The well-defined contact between coarse-grained, wave-built facies and overlying aeolian deposits is used to demonstrate the dominant influence of RSL change in the development of the barrier system and, with chronology provided by OSL dating, produce a RSL curve for the 2500-year period of its formation. A net increase of 2.4 m in the surface elevation of wave-built facies is observed across the plain, corresponding to an overall increase in mean sea level through time. Three distinct periods can be distinguished: (1) an increase from 2.4 to 1 m below modern MSL between 2400 and 1500 years (rate: +1.3 mm/yr); (2) relatively stable or slowly rising RSL (<+0.2 mm/yr) from 1400 to 700 years; and (3) a rise of ca. 0.7 m during the past 700 years (+1.1 mm/yr). This study presents a moderate-resolution RSL curve for southern Newfoundland over the last 2500 years and a field demonstration of the utility of wave-built/aeolian stratigraphic contacts in beach ridges for sea-level reconstructions in mixed clastic systems.
Simpsy, Gurram Samuel; Sajjan, Girija S.; Mudunuri, Padmaja; Chittem, Jyothi; Prasanthi, Nalam N. V. D.; Balaga, Pankaj
2016-01-01
Introduction: M-Wire and reciprocating motion of WaveOne and controlled memory (CM) wire) of HyFlex were the recent innovations using thermal treatment. Therefore, a study was planned to evaluate the shaping ability of reciprocating motion of WaveOne and HyFlex using cone beam computed tomography (CBCT). Methodology: Forty-five freshly extracted mandibular teeth were selected and stored in saline until use. All teeth were scanned pre- and post-operatively using CBCT (Kodak 9000). All teeth were accessed and divided into three groups. (1) Group 1 (control n = 15): Instrumented with ProTaper. (2) Group 2 (n = 15): Instrumented with primary file (8%/25) WaveOne. (3) Group 3 (n = 15): Instrumented with (4%/25) HyFlex CM. Sections at 1, 3, and 5 mm were obtained from the pre- and post-operative scans. Measurement was done using CS3D software and Adobe Photoshop software. Apical transportation and degree of straightening were measured and statistically analyzed. Results: HyFlex showed lesser apical transportation when compared to other groups at 1 and 3 mm. WaveOne showed lesser degree of straightening when compared to other groups. Conclusion: This present study concluded that all systems could be employed in routine endodontics whereas HyFlex and WaveOne could be employed in severely curved canals. PMID:27994323
Alignment and phasing of deployable telescopes
NASA Technical Reports Server (NTRS)
Woolf, N. J.; Ulich, B. L.
1983-01-01
The experiences in coaligning and phasing the Multi-Mirror Telescope (MMT), together with studies in setting up radio telescopes, are presented. These experiences are discussed, and on the basis they furnish, schemes are suggested for coaligning and phasing four large future telescopes with complex primary mirror systems. These telescopes are MT2, a 15-m-equivalent MMT, the University of California Ten Meter Telescope, the 10 m sub-mm wave telescope of the University of Arizona and the Max Planck Institute for Radioastronomy, and the Large Deployable Reflector, a future space telescope for far-IR and sub-mm waves.
Wu, Bailin; Lu, Minjie; Zhang, Yan; Song, Bo; Ling, Jian; Huang, Jinghan; Yin, Gang; Lan, Tian; Dai, Linlin; Song, Lei; Jiang, Yong; Wang, Hao; He, Zuoxiang; Lee, Jongmin; Yong, Hwan Seok; Patel, Mehul B; Zhao, Shihua
2017-02-01
Patients with unexplainable giant T-wave inversion in the precordial leads and apical wall thickness <15 mm have been reported. These patients cannot be diagnosed as apical hypertrophic cardiomyopathy (AHCM) according to the current criteria. The objective of this study was to evaluate the apical morphological features of this type of patients using cardiac magnetic resonance. Institutional ethics approval and written informed consent were obtained. A total of 60 subjects with unexplainable giant T-wave inversion and 76 healthy volunteers were prospectively enrolled in the study. The segmented left ventricular (LV) wall thickness was measured according to the American Heart Association 17-segmented model. The apical angle (apA) as well as the regional variations in LV wall thickness was analysed. Considerable variation in LV wall thickness in normals was observed with progressive thinning from the base to apex (male and female, P < 0.01). The apical thickness of subjects with giant T-wave inversion was 8.10 ± 1.67 mm in male, which is thicker than that of controls (4.14 ± 1.17 mm, P < 0.01). In female, the apical thickness was also significantly different from controls (5.85 ± 2.16 vs. 2.99 ± 0.65 mm, P < 0.01). Compared with normals, the apA decreased significantly in male (87.44 ± 13.86 vs.115.03 ± 9.90°, P < 0.01) and female (90.69 ± 8.84 vs. 110.07 ± 13.58°, P < 0.01) subjects, respectively. Although the absolute thickness of apical wall was below the current diagnostic criteria of AHCM, the apical morphological features of subjects with unexplainable giant T-wave inversion were significantly different from normals. Whether these subjects should be included into a preclinical scope of AHCM needs further investigations. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Infragravity waves in the deep ocean: An upward revision
NASA Astrophysics Data System (ADS)
Aucan, J.; Ardhuin, F.
2013-07-01
Ocean infragravity waves are surface gravity waves with periods of several minutes and corresponding wavelengths of up to tens of kilometers. When propagating freely in the deep ocean, these waves are typically small, several centimeters at most, so they have been seldom studied. In the context of future wide-swath altimetry missions, these waves need to be better quantified as they have wavelengths that will be resolved by such instruments. Here, we analyze the global climatology and variability of infragravity waves in the deep ocean using data from over 40 open ocean locations, with depths larger than 2000 m. We show that typical infragravity wave heights are higher than previously estimated, with winter-averaged values up to 11 mm off the U.S. West Coast, and typically less than 6 mm in the tropics. The mid to high latitudes exhibit a strong seasonal cycle consistent with the local variability of the wind-waves, while the tropical Pacific has a higher energy level during the Austral winter that does not correlate well with the local wind-waves, suggesting a remote source for the recorded infragravity waves. These infragravity wave energies are expected to be a significant contribution to the error budget for possible measurements of sea level associated to sub-mesoscale currents at horizontal scales around 10 km. Hence, a global numerical model of infragravity waves will likely be necessary for the analysis of the planned Surface Water Ocean Topography mission.
Acoustic Levitation Transportation of Small Objects Using a Ring-type Vibrator
NASA Astrophysics Data System (ADS)
Thomas, Gilles P. L.; Andrade, Marco A. B.; Adamowski, Julio C.; Silva, Eḿílio C. N.
A new device for noncontact transportation of small solid objects is presented here. Ultrasonic flexural vibrations are generated along the ring shaped vibrator using two Langevin transducers and by using a reflector parallel to the vibrator, small particles are trapped at the nodal points of the resulting acoustic standing wave. The particles are then moved by generating a traveling wave along the vibrator, which can be done by modulating the vibration amplitude of the transducers. The working principle of the traveling wave along the vibrator has been modeled by the superposition of two orthogonal standing waves, and the position of the particles can be predicted by using finite element analysis of the vibrator and the resulting acoustic field. A prototype consisting of a 3 mm thick, 220 mm long, 50 mm wide and 52 mm radius aluminum ring-type vibrator and a reflector of the same length and width was built and small polystyrene spheres have been successfully transported along the straight parts of the vibrator.
Military microwaves '84; Proceedings of the Conference, London, England, October 24-26, 1984
NASA Astrophysics Data System (ADS)
The present conference on microwave frequency electronic warfare and military sensor equipment developments consider radar warning receivers, optical frequency spread spectrum systems, mobile digital communications troposcatter effects, wideband bulk encryption, long range air defense radars (such as the AR320, W-2000 and Martello), multistatic radars, and multimode airborne and interceptor radars. IR system and subsystem component topics encompass thermal imaging and active IR countermeasures, class 1 modules, and diamond coatings, while additional radar-related topics include radar clutter in airborne maritime reconnaissance systems, microstrip antennas with dual polarization capability, the synthesis of shaped beam antenna patterns, planar phased arrays, radar signal processing, radar cross section measurement techniques, and radar imaging and pattern analysis. Attention is also given to optical control and signal processing, mm-wave control technology and EW systems, W-band operations, planar mm-wave arrays, mm-wave monolithic solid state components, mm-wave sensor technology, GaAs monolithic ICs, and dielectric resonator and wideband tunable oscillators.
NASA Astrophysics Data System (ADS)
Yasui, M.; Matsumoto, E.; Arakawa, M.; Matsue, K.; Kobayashi, N.
2014-07-01
Introduction: A seismic wave survey is a direct method to investigate the sub-surface structures of solid bodies, so we measured and analyzed these seismic waves propagating through these interiors. Earthquake and Moonquake are the only two phenomena that have been observed to explore these interiors until now, while the future surveys on the other bodies, (solid planets and/or asteroids) are now planned. To complete a seismic wave survey during the mission period, an artificial method that activates the seismic wave is necessary and one candidate is a projectile collision on the target body. However, to utilize the artificial seismic wave generated on the target body, the relationship between the impact energy and the amplitude and the decay process of the seismic wave should be examined. If these relationships are clarified, we can estimate the required sensitivity of seismometers installed on the target body and the possible distance from the seismic origin measurable for the seismometer. Furthermore, if we can estimate the impact energy from the observed seismic wave, we expect to be able to estimate the impact flux of impactors that collided on the target body. McGarr et al. (1969) did impact experiments by using the lexan projectile and two targets, quartz sand and sand bonded by epoxy cement, at 0.8-7 km/s. They found a difference of seismic wave properties between the two targets, and calculated the conversion efficiency to discuss the capability of detection of seismic waves on the Moon. However, they did not examine the excitation and propagation properties of the seismic waves in detail. In this study, we carried out impact experiments in the laboratory to observe the seismic waves by accelerometers, and examined the effects of projectile properties on the excitation and propagation properties of the seismic waves. Experimental methods: We made impact experiments by using a one-stage gas gun at Kobe University. Projectiles were a polycarbonate cylinder with a diameter of 10 mm and a height of 10 mm, and stainless steel and alumina balls with a diameter of 3 mm. The stainless steel and alumina projectiles were accelerated with a sabot made of polyethylene. The impact velocity was from 20 to 100 m/s. The target was a non-cohesive glass bead with a mean particle diameter of 200 μ m prepared by putting the particles into a container with a diameter of 300 mm and a height of 100 mm, up to 80 mm depth. The target porosity was about 40%. A chamber that we set the target in was evacuated below 1000 Pa. Three accelerometers (response frequency < 10 kHz) were set on the target surface at different distances from the impact point. The observed seismic waves were recorded on a data logger (A/D conversion rate 100 kHz). Experimental results: First, we examined the propagation velocity of the seismic wave by using the traveling time from the impact point to the site of the accelerometer, then the impact velocity was obtained to be 105 ± 15 m/s. Next, we discovered that the maximum acceleration, g_max, had a good relationship to the normalized distance, x/R (x: distance from impact point, R: crater radius) and it was fitted by the following equation, g_max=268(x/R)^{-2.8}, irrespective of projectile types. These results mean that the seismic wave attenuates with a similar waveform scaled by the crater radius on the same target. The duration keeping the maximum acceleration was measured to have a half width of g_max peak on the waveform, and it was estimated to be ˜0.3 ms. This value is almost consistent with the penetration time of projectiles estimated by the model proposed by Niimi et al. (2011). McGarr et al. (1969) studied the momentum conversion efficiency from the projectile momentum to the target momentum transferred by the seismic wave and obtained it as the ratio of the momentum calculated by the particle motion, I, to the projectile momentum, I_p. In our study, the I/I_p was obtained to be 0.23-1.56. This range was almost consistent with that of McGarr et al. (1969), 0.39-1.62. We can conclude that I/I_p is independent of the impact velocity. Implications for planetary exploration: According to the previous results, we can discuss the sensitivity of the seismometer to detect the seismic wave induced by an artificial impactor on asteroids. We calculated the maximum acceleration on asteroids with two different sizes, such as the sizes of Eros and 1999JU3, by assuming that the projectile made of copper with a mass of 2 kg impacted at 2 km/s. In this calculation, we used the crater scaling law and the attenuation equation of g_max obtained in our study. As a result, the seismometer could detect the seismic wave only around the crater cavity on an Eros-sized asteroid while it could detect the wave globally on a 1999JU3-sized asteroid.
NASA Astrophysics Data System (ADS)
Garkushin, Gennady; Kanel, Gennady I.; Razorenov, Sergey V.
2012-03-01
The Hugoniot elastic limit and spall strength of Ma2-1 magnesium deformable alloy were measured at the sample thickness varied from 0.25 mm to 10 mm at room and elevated temperatures. By means of analysis of decay of an elastic precursor wave it is found that initial plastic strain rate decreases from 2×105 s-1 at distance of 0.25 mm to 103 s-1 at distance of 10 mm. The strain rate in plastic shock wave is by order of magnitude higher at the same value of the shear stress. The spall strength of the alloy grows with increasing the strain rate and decreases with approach to the solidus temperature.
2007-06-01
radiation flows upward, it passes though a 1.7-mm high, tapered, 25-μm thick gold wall cone that is filled 20 ± 3 mg/cm3 silica aerogel (SiO2). Above...this cone is a 20 ± 3 mg/cm3 silica aerogel filled, 1-mm high, 2.4-mm inner diameter, 25-μm thick gold wall cylinder. On the cylinder rests a 4-mm...diameter gold platform that supports a higher density (40-60 mg/cm3) silica aerogel . This aerogel is the region where the blast wave forms after
Microclimate and actual evapotranspiration in a humid coastal-plain environment
Dennehy, K.F.; McMahon, P.B.
1987-01-01
Continuous hourly measurements of twelve meteorologic variables recorded during 1983 and 1984 were used to examine the microclimate and actual evapotranspiration at a low-level radioactive-waste burial site near Barnwell, South Carolina. The study area is in the Atlantic Coastal Plain of southwestern South Carolina. Monthly, daily, and hourly trends in net radiation, incoming and reflected short-wave radiation, incoming and emitted long-wave radiation, soil-heat flux, dry- and wet-bulb temperatures, soil temperatures, wind direction and speed, and precipitation were used to characterize the microclimate. Average daily air temperatures ranged from -9 to 32?? Celsius during the period of study. Net radiation varied from about -27 to 251 watts m-2 and was dominated by incoming short-wave radiation throughout the year. The peak net radiation during a summer day generally occurred 2-3h before the peak vapor pressure deficit. In the winter, these peaks occurred at about the same time of day. Monthly precipitation varied from 15 to 241 mm. The Bowen ratio method was used to estimate hourly evapotranspiration, which was summed to also give daily and monthly evapotranspiration. Actual evapotranspiration varied from 0.0 to 0.7 mm h-1, 0.8-5 mm d-1, and 20-140 mm month-1 during 1983 and 1984. The maximum rate of evapotranspiration generally occurred at the same time of day as maximum net radiation, suggesting net radiation was the main driving force for evapotranspiration. Precipitation exceeded evapotranspiration during 14 months of the 2yr study period. Late fall, winter, and early spring contained the majority of these months. The maximum excess precipitation was 115 mm in February 1983. ?? 1987.
Polónia, Jorge; Olival, Catarina; Ribeiro, Sílvia; Silva, José A; Barbosa, Loide
2014-06-01
We investigated viscoelastic properties of the arterial wall in women with previous preeclampsia (PE) compared to those with normal pregnancy (NP). In a cross-sectional study 45 women with previous PE and 55 with NP were included, matched for age (PE 38±6 vs. NP 38±5 years, NS) and body mass index: (PE 25±4 vs. NP 26±4 kg/m(2), NS) studied, respectively, 76±34 and 86±48 months after delivery. We assessed arterial distensibility - pulse wave velocity (PWV, Complior) and reflected waves (augmentation pressure [AP], mmHg) and augmentation index (AIx) - in the central pressure wave and blood pressure (BP) on 24-h ambulatory BP monitoring (ABPM). PE showed higher (p<0.01) peripheral systolic blood pressure (SBP): PE 131±18 vs. NP 121±19, and central SBP: PE 122±18 vs. NP 110±19 mmHg, with less amplification of central-peripheral pressure: PE 10±4 vs. NP 12±5, p=0.041, and higher (p<0.05) AP: PE 10±3 vs. NP 8±2, and AIx: PE 26±5 vs. NP 20±5 mmHg, but PE and NP did not differ in pulse wave velocity. On ABPM, PE (n=39) vs. NP (n=33) had higher nighttime SBP: PE 121±10 vs. NP 108±10 mmHg and lower percentage nocturnal SBP fall: PE 11±6 vs. NP 18±11%, both p<0.02. During follow-up, the need for antihypertensive medication was seven times higher in PE than in NP. Women with previous PE have a greater risk of hypertension, higher nighttime BP values, blunted nocturnal BP fall and changes in central pressure suggestive of increased reflected waves and peripheral vascular resistance. These factors may contribute to their higher cardiovascular risk after pregnancy. Copyright © 2013 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.
Verification Test of the SURF and SURFplus Models in xRage: Part II
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menikoff, Ralph
2016-06-20
The previous study used an underdriven detonation wave (steady ZND reaction zone profile followed by a scale invariant rarefaction wave) for PBX 9502 as a validation test of the implementation of the SURF and SURFplus models in the xRage code. Even with a fairly fine uniform mesh (12,800 cells for 100mm) the detonation wave profile had limited resolution due to the thin reaction zone width (0.18mm) for the fast SURF burn rate. Here we study the effect of finer resolution by comparing results of simulations with cell sizes of 8, 2 and 1 μm, which corresponds to 25, 100 andmore » 200 points within the reaction zone. With finer resolution the lead shock pressure is closer to the von Neumann spike pressure, and there is less noise in the rarefaction wave due to fluctuations within the reaction zone. As a result the average error decreases. The pointwise error is still dominated by the smearing the pressure kink in the vicinity of the sonic point which occurs at the end of the reaction zone.« less
NASA Technical Reports Server (NTRS)
Wu, Dong L.; Zhang, Fuqing
2004-01-01
Satellite microwave data are used to study gravity wave properties and variabilities over the northeastern United States and the North Atlantic in the December-January periods. The gravity waves in this region, found in many winters, can reach the stratopause with growing amplitude. The Advanced Microwave Sounding Unit-A (AMSU-A) observations show that the wave occurrences are correlated well with the intensity and location of the tropospheric baroclinic jet front systems. To further investigate the cause(s) and properties of the North Atlantic gravity waves, we focus on a series of wave events during 19-21 January 2003 and compare AMSU-A observations to simulations from a mesoscale model (MM5). The simulated gravity waves compare qualitatively well with the satellite observations in terms of wave structures, timing, and overall morphology. Excitation mechanisms of these large-amplitude waves in the troposphere are complex and subject to further investigations.
Torricelli, Fabio C M; Marchini, Giovanni S; Yamauchi, Fernando I; Danilovic, Alexandre; Vicentini, Fabio C; Srougi, Miguel; Monga, Manoj; Mazzucchi, Eduardo
2015-06-01
We evaluated which variables impact fragmentation and clearance of lower pole calculi after shock wave lithotripsy. We prospectively evaluated patients undergoing shock wave lithotripsy for a solitary 5 to 20 mm lower pole kidney stone between June 2012 and August 2014. Patient body mass index and abdominal waist circumference were recorded. One radiologist blinded to shock wave lithotripsy outcomes measured stone size, area and density, stone-to-skin distance, infundibular length, width and height, and infundibulopelvic angle based on baseline noncontrast computerized tomography. Fragmentation, success (defined as residual fragments less than 4 mm in asymptomatic patients) and the stone-free rate were evaluated by noncontrast computerized tomography 12 weeks postoperatively. Univariate and multivariate analysis was performed. A total of 100 patients were enrolled in the study. Mean stone size was 9.1 mm. Overall fragmentation, success and stone-free rates were 76%, 54% and 37%, respectively. On logistic regression body mass index (OR 1.27, 95% CI 1.11-1.49, p = 0.004) and stone density (OR 1.0026, 95% CI 1.0008-1.0046, p = 0.005) significantly impacted fragmentation. Stone size (OR 1.24, 95% CI 1.07-1.48, p = 0.039) and stone density (OR 1.0021, 95% CI 1.0007-1.0037, p = 0.012) impacted the success rate while stone size (OR 1.24, 95% CI 1.04-1.50, p = 0.029), stone density (OR 1.0015, 95% CI 1.0001-1.0032, p = 0.046) and infundibular length (OR 1.1035, 95% CI 1.015-1.217, p = 0.015) impacted the stone-free rate. The best outcomes were found in patients with a body mass index of 30 kg/m(2) or less, stones 10 mm or less and 900 HU or less, and an infundibular length of 25 mm or less. The coexistence of significant unfavorable variables led to a stone-free rate of less than 20%. Obese patients with higher than 10 mm density stones (greater than 900 HU) in the lower pole of the kidney with an infundibular length of greater than 25 mm should be discouraged from undergoing shock wave lithotripsy. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Detection of foreign bodies in foods using continuous wave terahertz imaging.
Lee, Young-Ki; Choi, Sung-Wook; Han, Seong-Tae; Woo, Deog Hyun; Chun, Hyang Sook
2012-01-01
Foreign bodies (FBs) in food are health hazards and quality issues for many food manufacturers and enforcement authorities. In this study, continuous wave (CW) terahertz (THz) imaging at 0.2 THz with an output power of 10 mW was compared with X-ray imaging as techniques for inspection of food for FBs. High-density FBs, i.e., aluminum and granite pieces of various sizes, were embedded in a powdered instant noodle product and detected using THz and X-ray imaging. All aluminum and granite pieces (regular hexahedrons with an edge length of 1 to 5 mm) were visualized by both CW THz and X-ray imaging. THz imaging also detected maggots (length = 8 to 22 mm) and crickets (length = 35 and 50 mm), which were embedded in samples as low density FBs. However, not all sizes of maggot pieces embedded in powdered instant noodle were detected with X-ray imaging, although larger crickets (length = 50 mm and thickness = 10 mm) were detected. These results suggest that CW THz imaging has potential for detecting both high-density and low-density FBs embedded in food.
Le, Nhan; Song, ShaoZhen; Nabi, Ghulam; Wang, Ruikang; Huang, Zhihong
2016-09-01
Phase-sensitive optical coherence tomography (PhS-OCT) is proposed, as a new high intensity focused ultrasound (HIFU) imaging guidance to detect and track HIFU focus inside 1% agar samples in this work. The experiments studied the effect of varying HIFU power on the induction of shear wave, which can be implemented as a new technique to monitor focused ultrasound surgery (FUS). A miniature HIFU transducer (1.02 MHz, 20 mm aperture diameter, 15 mm radius of curvature) was produced in-house, pressure-field mapped, and calibrated. The transducer was then embedded inside a 1% agar phantom, which was placed under PhS-OCT for observation, under various HIFU power settings (acoustic power, and number of cycles per pulse). Shear wave was induced on the sample surface by HIFU and was captured in full under PhS-OCT. The lowest HIFU acoustic power output for the detection of shear wave was found to be 0.36 W (1.02 MHz, 100 cycles/pulse), or with the number of cycles/pulse as low as 20 (1.02 MHz, 0.98 W acoustic power output). A linear relationship between acoustic power output and the maximum shear wave displacement was found in the first study. The second study explores a non-linear correlation between the (HIFU) numbers of cycles per pulse, and the maximum shear wave displacement. PhS-OCT demonstrates excellent tracking and detection of HIFU-induced shear wave. The results could benefit other imaging techniques in tracking and guiding HIFU focus. Further studies will explore the relationship between the physical transducer characteristics and the HIFU-induced shear wave.
Effect of canal length and curvature on working length alteration with WaveOne reciprocating files.
Berutti, Elio; Chiandussi, Giorgio; Paolino, Davide Salvatore; Scotti, Nicola; Cantatore, Giuseppe; Castellucci, Arnaldo; Pasqualini, Damiano
2011-12-01
This study evaluated the working length (WL) modification after instrumentation with WaveOne Primary (Dentsply Maillefer, Ballaigues, Switzerland) reciprocating files and the incidence of overinstrumentation in relation to the initial WL. Thirty-two root canals of permanent teeth were used. The angles of curvature of the canals were calculated on digital radiographs. The initial WL with K-files was transferred to the matched WaveOne Primary reciprocating files. After glide paths were established with PathFile (Dentsply Maillefer, Ballaigues, Switzerland), canals were shaped with WaveOne Primary referring to the initial WL. The difference between the postinstrumentation canal length and the initial canal length was analyzed by using a fiberoptic inspection microscope. Data were analyzed with a balanced 2-way factorial analysis of variance (P < .05). Referring to the initial WL, 24 of 32 WaveOne Primary files projected beyond the experimental apical foramen (minimum-maximum, 0.14-0.76 mm). A significant decrease in the canal length after instrumentation (95% confidence interval ranging from -0.34 mm to -0.26 mm) was detected. The canal curvature significantly influenced the WL variation (F(1) = 30.65, P < .001). The interaction between the initial canal length and the canal curvature was statistically significant (F(2) = 4.38, P = .014). Checking the WL before preparation of the apical third of the root canal is recommended when using the new WaveOne NiTi single-file system. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Experimental Insights into the Mechanisms of Particle Acceleration by Shock Waves
NASA Astrophysics Data System (ADS)
Scolamacchia, T.; Scheu, B.; Dingwell, D. B.
2011-12-01
The generation of shock waves is common during explosive volcanic eruptions. Particles acceleration following shock wave propagation has been experimentally observed suggesting the potential hazard related to this phenomenon. Experiments and numerical models focused on the dynamics of formation and propagation of different types of shock waves when overpressurized eruptive mixtures are suddenly released in the atmosphere, using a pseudo-gas approximation to model those mixtures. Nevertheless, the results of several studies indicated that the mechanism of coupling between a gas and solid particles is valid for a limited grain-size range, which at present is not well defined. We are investigating particle acceleration mechanisms using a vertical shock tube consisting of a high-pressure steel autoclave (450 mm long, 28 mm in diameter), pressurized with argon, and a low-pressure 140 mm long acrylic glass autoclave, with the same internal diameter of the HP reservoir. Shock waves are generated by Ar decompression at atmospheric pressures at Pres/Pamb 100:1 to 150:1, through the failure of a diaphragm. Experiments were performed either with empty autoclave or suspending solid analogue particles 150 μm in size inside the LP autoclave. Incident Mach number varied from 1.7 to 2.1. Absolute and relative pressure sensors monitored P histories during the entire process, and a high-speed camera recorded particles movement at 20,000 to 30,000 fps. Preliminary results indicate pressure multiplication at the contact between shock waves and the particles in a time lapse of 100s μs, suggesting a possible different mechanism with respect to gas-particle coupling for particle acceleration.
NASA Astrophysics Data System (ADS)
Jansen, E. Duco; Asshauer, Thomas; Frenz, Martin; Delacretaz, Guy P.; Motamedi, Massoud; Welch, Ashley J.
1995-05-01
Mechanical injury during pulsed laser ablation of tissue is caused by rapid bubble expansions and collapse or by laser-induced pressure waves. In this study the effect of material elasticity on the ablation process has been investigated. Polyacrylamide tissue phantoms with various water concentrations (75-95%) were made. The Young's moduli of the gels were determined by measuring the stress-strain relationship. An optical fiber (200 or 400 micrometers ) was translated into the clear gel and one pulse of holmium:YAG laser radiation was given. The laser was operated in either the Q-switched mode (tau) p equals 500 ns, Qp equals 14 +/- 1 mJ, 200 micrometers fiber, Ho equals 446 mJ/mm2) or the free-running mode ((tau) p equals 100 microsecond(s) , Qp equals 200 +/- 5 mJ, 400 micrometers fiber, Ho equals 1592 mJ/mm2). Bubble formation inside the gels was recorded using a fast flash photography setup while simultaneously recording pressures with a PVDP needle hydrophone (40 ns risetime) positioned in the gel, approximately 2 mm away from the fibertip. A thermo-elastic expansion wave was measured only during Q-switched pulse delivery. The amplitude of this wave (approximately equals 40 bar at 1 mm from the fiber) did not vary significantly in any of the phantoms investigated. Rapid bubble formation and collapse was observed inside the clear gels. Upon bubble collapse, a pressure transient was emitted; the amplitude of this transient depended strongly on bubble size and geometry. It was found that (1) the bubble was almost spherical for the Q-switched pulse and became more elongated for the free-running pulse, and (2) the maximum bubble size and thus the collapse amplitude decreased with an increase in Young's modulus (from 68 +/- 11 bar at 1 mm in 95% water gel to 25 +/- 10 bar at 1 mm in 75% water gel).
Zhou, Wen; Li, Xinying; Yu, Jianjun
2017-10-30
We propose QPSK millimeter-wave (mm-wave) vector signal generation for D-band based on balanced precoding-assisted photonic frequency quadrupling technology employing a single intensity modulator without an optical filter. The intensity MZM is driven by a balanced pre-coding 37-GHz QPSK RF signal. The modulated optical subcarriers are directly sent into the single ended photodiode to generate 148-GHz QPSK vector signal. We experimentally demonstrate 1-Gbaud 148-GHz QPSK mm-wave vector signal generation, and investigate the bit-error-rate (BER) performance of the vector signals at 148-GHz. The experimental results show that the BER value can be achieved as low as 1.448 × 10 -3 when the optical power into photodiode is 8.8dBm. To the best of our knowledge, it is the first time to realize the frequency-quadrupling vector mm-wave signal generation at D-band based on only one MZM without an optical filter.
New materials and techniques for improved mm wave devices
NASA Technical Reports Server (NTRS)
Alterovitz, Samuel A.
1991-01-01
Current research on microwave and mm wave three terminal semiconductor devices is summarized with particular attention given to the development of the pseudomorphic InGaAs modulation-doped field effect transistor (MODFET). Application of the high-indium-concentration MODFET grown on InP in the temperature range of 120-150 K is also described.
Using InterWave Aberrometry to Measure and Improve the Quality of Vision in LASIK Surgery
Thompson, Keith P.; Staver, P. Randall; Garcia, Jose R.; Burns, Stephen A.; Webb, Robert H.; Stulting, R. Doyle
2005-01-01
Objective To compare visual outcomes in eyes undergoing aberrometry-guided (InterWave) LASIK with those in eyes undergoing standard LASIK treatment based upon refractive measures. Design Single-center, comparative, interventional, consecutive case series. Participants Four hundred two consecutive eyes undergoing LASIK were analyzed retrospectively. One group, 106 eyes undergoing primary LASIK and 224 eyes undergoing LASIK enhancement, was treated with standard LASIK treatment using a 5.5-mm optical zone, 1.5-mm transition zone laser with the settings determined by manifest refraction. The second group, 44 untreated (primary) eyes and 28 previously treated (enhancement) eyes, received a multipass, multistage treatment in which the laser settings for each stage were determined by aberrometry measurements. Eyes with desired monovision (undercorrected) outcome and preoperative hyperopia were excluded from the study. Intervention An aberrometry-guided laser treatment (InterWave LASIK) was compared with the standard LASIK treatment based upon the manifest refraction. Main Outcome Measures Uncorrected visual acuity (VA), manifest refraction, best spectacle-corrected VA (BSCVA), severity of halos, and root mean square (RMS) retinal blur area measured at 3 months postoperatively. Results Three months postoperatively there was no difference in uncorrected VA, BSCVA, refraction, or RMS retinal blur areas for pupil sizes of 3.5 mm between eyes treated by InterWave and those treated by standard LASIK. However, InterWave LASIK reduced the retinal blur area by 48% (P<0.0103) and 58% (P<0.0004) in primary cases and 43% (P<0.0430) and 74% (P<0.0271) in enhancement cases, respectively, for pupil sizes of 4.5 and 6.5 mm relative to standard LASIK treatments. Patients undergoing InterWave-guided treatment reported less severity of halo (0.37 vs. 0.98 [P<0.016] for primary cases and 0.35 vs. 0.73 [P<0.04] for enhancement cases). Conclusion InterWave LASIK achieved acuity and refractive results equivalent to those of standard LASIK treatment based upon refraction, but resulted in superior quality mesopic vision. PMID:15234139
Real-time measurement of biomagnetic vector fields in functional syncytium using amorphous metal.
Nakayama, Shinsuke; Uchiyama, Tusyoshi
2015-03-06
Magnetic field detection of biological electric activities would provide a non-invasive and aseptic estimate of the functional state of cellular organization, namely a syncytium constructed with cell-to-cell electric coupling. In this study, we investigated the properties of biomagnetic waves which occur spontaneously in gut musculature as a typical functional syncytium, by applying an amorphous metal-based gradio-magneto sensor operated at ambient temperature without a magnetic shield. The performance of differentiation was improved by using a single amorphous wire with a pair of transducer coils. Biomagnetic waves of up to several nT were recorded ~1 mm below the sample in a real-time manner. Tetraethyl ammonium (TEA) facilitated magnetic waves reflected electric activity in smooth muscle. The direction of magnetic waves altered depending on the relative angle of the muscle layer and magneto sensor, indicating the existence of propagating intercellular currents. The magnitude of magnetic waves rapidly decreased to ~30% by the initial and subsequent 1 mm separations between sample and sensor. The large distance effect was attributed to the feature of bioelectric circuits constructed by two reverse currents separated by a small distance. This study provides a method for detecting characteristic features of biomagnetic fields arising from a syncytial current.
Real-time Measurement of Biomagnetic Vector Fields in Functional Syncytium Using Amorphous Metal
NASA Astrophysics Data System (ADS)
Nakayama, Shinsuke; Uchiyama, Tusyoshi
2015-03-01
Magnetic field detection of biological electric activities would provide a non-invasive and aseptic estimate of the functional state of cellular organization, namely a syncytium constructed with cell-to-cell electric coupling. In this study, we investigated the properties of biomagnetic waves which occur spontaneously in gut musculature as a typical functional syncytium, by applying an amorphous metal-based gradio-magneto sensor operated at ambient temperature without a magnetic shield. The performance of differentiation was improved by using a single amorphous wire with a pair of transducer coils. Biomagnetic waves of up to several nT were recorded ~1 mm below the sample in a real-time manner. Tetraethyl ammonium (TEA) facilitated magnetic waves reflected electric activity in smooth muscle. The direction of magnetic waves altered depending on the relative angle of the muscle layer and magneto sensor, indicating the existence of propagating intercellular currents. The magnitude of magnetic waves rapidly decreased to ~30% by the initial and subsequent 1 mm separations between sample and sensor. The large distance effect was attributed to the feature of bioelectric circuits constructed by two reverse currents separated by a small distance. This study provides a method for detecting characteristic features of biomagnetic fields arising from a syncytial current.
Torsional Alfvén Waves in a Dipolar Magnetic Field
NASA Astrophysics Data System (ADS)
Nataf, H. C.; Tigrine, Z.; Cardin, P.; Schaeffer, N.
2017-12-01
The discovery of torsional Alfvén waves in the Earth's core (Gillet et al, 2010) is a strong motivation for investigating the properties of these waves. Here, we report on the first experimental study of such waves. Alfvén waves are difficult to excite and observe in liquid metals because of their high magnetic diffusivity. Nevertheless, we obtained clear signatures of such diffusive waves in our DTS experiment. In this setup, some 40 liters of liquid sodium are contained between a ro = 210 mm-radius stainless steel outer shell, and a ri = 74 mm-radius copper inner sphere. Both spherical boundaries can rotate independently around a common vertical axis. The inner sphere shells a strong permanent magnet, which produces a nearly dipolar magnetic field whose intensity falls from 175 mT at ri to 8 mT at ro in the equatorial plane. We excite Alfvén waves in the liquid sodium by applying a sudden jerk of the inner sphere. To study the effect of global rotation, which leads to the formation of geostrophic torsional Alfvén waves, we spin the experiment at rotation rates fo = fi up to 15 Hz. The Alfvén wave produces a clear azimuthal magnetic signal on magnetometers installed in a sleeve inside the fluid. We also probe the associated azimuthal velocity field using ultrasound Doppler velocimetry. Electric potentials at the surface of the outer sphere turn out to be very revealing as well. In parallel, we use the XSHELLS magnetohydrodynamics spherical code to model torsional Alfvén waves in the experimental conditions, and beyond. We explore both linear and non-linear regimes. We observe a strong excitation of inertial waves in the equatorial plane, where the wave transits from a region of strong magnetic field to a region dominated by rotation (see figure of meridian map of azimuthal velocity). These novel observations should help deciphering the dynamics of Alfvén waves in planetary cores.
High strain rate deformation and fracture of the magnesium alloy Ma2-1 under shock wave loading
NASA Astrophysics Data System (ADS)
Garkushin, G. V.; Kanel', G. I.; Razorenov, S. V.
2012-05-01
This paper presents the results of measurements of the dynamic elastic limit and spall strength under shock wave loading of specimens of the magnesium alloy Ma2-1 with a thickness ranging from 0.25 to 10 mm at normal and elevated (to 550°C) temperatures. From the results of measurements of the decay of the elastic precursor of a shock compression wave, it has been found that the plastic strain rate behind the front of the elastic precursor decreases from 2 × 105 s-1 at a distance of 0.25 mm to 103 s-1 at a distance of 10 mm. The plastic strain rate in a shock wave is one order of magnitude higher than that in the elastic precursor at the same value of the shear stress. The spall strength of the alloy decreases as the solidus temperature is approached.
Ultrasonic investigation of granular materials subjected to compression and crushing.
Gheibi, Amin; Hedayat, Ahmadreza
2018-07-01
Ultrasonic wave propagation measurement has been used as a suitable technique for studying the granular materials and investigating the soil fabric structure, the grain contact stiffness, frictional strength, and inter-particle contact area. Previous studies have focused on the variations of shear and compressional wave velocities with effective stress and void ratio, and lesser effort has been made in understanding the variation of amplitude and dominant frequency of transmitted compressional waves with deformation of soil packing. In this study, continuous compressional wave transmission measurements during compaction of unconsolidated quartz sand are used to investigate the impact of soil layer deformation on ultrasonic wave properties. The test setup consisted of a loading machine to apply constant loading rate to a sand layer (granular quartz) of 6 mm thickness compressed between two forcing blocks, and an ultrasonic wave measurement system to continuously monitor the soil layer during compression up to 48 MPa normal stress. The variations in compressional wave attributes such as wave velocity, transmitted amplitude, and dominant frequency were studied as a function of the applied normal stress and the measured normal strain as well as void ratio and particle size. An increasing trend was observed for P-wave velocity, transmitted amplitude and dominant frequency with normal stress. In specimen with the largest particle size (D 50 = 0.32 mm), the wave velocity, amplitude and dominant frequency were found to increase about 230%, 4700% and 320% as the normal stress reached the value of 48 MPa. The absolute values of transmitted wave amplitude and dominant frequency were greater for specimens with smaller particle sizes while the normalized values indicate an opposite trend. The changes in the transmitted amplitude were linked to the changes in the true contact area between the particles with a transitional point in the slope of normalized amplitude, coinciding with the yield stress of the granular soil layer. The amount of grain crushing as a result of increase in the normal stress was experimentally measured and a linear correlation was found between the degree of grain crushing and the changes in the normalized dominant frequency of compressional waves. Copyright © 2018 Elsevier B.V. All rights reserved.
Decreased Retinal-Choroidal Blood Flow in Retinitis Pigmentosa as measured by MRI
Zhang, Yi; Harrison, Joseph M; Nateras, Oscar San Emeterio; Chalfin, Steven; Duong, Timothy Q
2013-01-01
Purpose To evaluate retinal and choroidal blood flow (BF) using high-resolution magnetic resonance imaging (MRI) as well as visual function measured by the electroretinogram (ERG) in patients with retinitis pigmentosa (RP). Methods MRI studies were performed in 6 RP patients (29-67 years) and 5 healthy volunteers (29-64 years) on a 3-Tesla scanner with a custom-made surface coil. Quantitative BF was measured using the pseudo-continuous arterial-spin-labeling technique at 0.5x0.8x6.0mm. Full-field ERGs of all patients were recorded. Amplitudes and implicit times of standard ERGs were analyzed. Results Basal BF in the posterior retinal-choroid was 142±16 ml/100ml/min (or 1.14±0.13 μl/mm2/min) in the control group and was 70±19 ml/100ml/min (or 0.56±0.15 μl/mm2/min) in the RP group. Retinal-choroidal BF was significantly reduced by 52±8% in RP patients compared to controls (P<0.05). ERG a- and b-wave amplitudes of RP patients were reduced and b-wave implicit times were delayed. There were statistically significant correlations between a-wave amplitude and BF value (r=0.9, P<0.05) but not between b-wave amplitude and BF value (r =0.7, P=0.2). Conclusions This study demonstrates a novel non-invasive MRI approach to measure quantitative retinal and choroidal BF in RP patients. We found that retinal-choroidal BF was markedly reduced and significantly correlated with reduced amplitudes of the a-wave of the standard combined ERG. PMID:23408312
Ground-based mm-wave emission spectroscopy for the detection and monitoring of stratospheric ozone
NASA Technical Reports Server (NTRS)
Parrish, A.; Dezafra, R.; Solomon, P.
1981-01-01
The molecular rotational spectrum of ozone is quite rich in the mm-wave region from 50 to 300 GHz. An apparatus, which was developed primarily for detection and measurement of stratospheric ClO and other trace molecules, is found to be well suited also for the observation of ozone lines. The collecting antenna of the apparatus is a simple mm-waveguide feedhorn. The detector is a superheterodyne mixer using a special high frequency Schottky diode and a klystron local oscillator. The spectrometer is a 256 channel filter bank with 1 MHz resolution per channel. The apparatus is believed to be the first ground-based mm-wave instrument having the capability of obtaining data of sufficient quality to make use of the inversion technique. The ground based radio technique is most sensitive to changes in vertical distribution in the region above 25 km, a region which is difficult to sample by other techniques.
Tonotopically Ordered Traveling Waves in the Hearing Organs of Bushcrickets in-vivo
NASA Astrophysics Data System (ADS)
Udayashankar, Arun Palghat; Kössl, Manfred; Nowotny, Manuela
2011-11-01
Experimental investigation of auditory mechanics in the mammalian cochlea has been difficult to address in-vivo due to its secure housing inside the temporal bone. Here we studied the easily accessible hearing organ of bushcrickets, located in their forelegs, known as the crista acustica. A characteristic feature of the organ is that it is lined with an array of auditory receptors in a tonotopic fashion with lower frequencies processed at the proximal part and higher frequencies at the distal part of the foreleg. Each receptor cell is associated with so called cap cells. The cap cells, graded in size, are directly involved in the mechanics of transduction along with the part of the acoustic trachea that supports the cap cells. Functional similarities between the crista acustica and the vertebrate cochlea such as frequency selectivity and distortion product otoacoustic emissions have been well documented. In this study we used laser Doppler vibrometry to study the mechanics of the organ and observed sound induced traveling waves (TW) along it's length. Frequency representation was tonotopic with TW propagating from the high frequency to the low frequency region of the organ similar to the situation in the cochlea. Traveling wave velocity increased monotonically from 4 to 12 m/s for a frequency range of 6 to 60 kHz, reflecting a smaller topographic spread (organ length: 1 mm) compared to the guinea pig cochlea (organ length: 18 mm). The wavelength of the traveling wave decreased monotonically from 0.67 mm to 0.27 mm for the same frequency range. Vibration velocity of the organ reached noise threshold levels (10 μm/s) at 30 dB SPL for a frequency of 21 kHz. A small non-linear compression (73 dB increase in velocity for an 80 dB increase in SPL) was also observed at the 21 kHz. Our results indicate that bushcrickets can be a good model system for exploration of auditory mechanics in-vivo.
NASA Astrophysics Data System (ADS)
Ma, Jianxin; Zhang, Junjie
2015-03-01
A novel full-duplex fiber-wireless link based on single sideband (SSB) optical millimeter (mm)-wave with 10 Gbit/s 4-pulse amplitude modulation (PAM) signal is proposed to provide alternative wired and 40 GHz wireless accesses for the user terminals. The SSB optical mm-wave with 4-PAM signal consists of two tones: one bears the 4-PAM signal and the other is unmodulated with high power. After transmission over the fiber to the hybrid optical network unit (HONU), the SSB optical mm-wave signal can be decomposed by fiber Bragg gratings (FBGs) as the SSB optical mm-wave signal with reduced carrier-to-sideband ratio (the baseband 4-PAM optical signal) and the uplink optical carrier for the wireless (wired) access. This makes the HONU free from the laser source. For the uplink, since the wireless access signal is converted to the baseband by power detection, both the transmitter in the HONU and the receiver in optical line terminal (OLT) are co-shared for both wireless and wired accesses, which makes the full duplex link much simpler. In our scheme, the optical electrical field of the square-root increment level 4-PAM signal assures an equal level spacing receiving for both the downlink wired and wireless accesses. Since the downlink wireless signal is down-converted to the baseband by power detection, RF local oscillator is unnecessary. To confirm the feasibility of our proposed scheme, a simulation full duplex link with 40 GHz SSB optical mm-wave with 10 Gbit/s 4-PAM signal is built. The simulation results show that both down- and up-links for either wired or wireless access can keep good performance even if the link length of the SSMF is extended to 40 km.
Oliveira, Bruna Paloma de; Câmara, Andréa Cruz; Duarte, Daniel Amancio; Heck, Richard John; Antonino, Antonio Celso Dantas; Aguiar, Carlos Menezes
2017-01-01
The objective of this study was to evaluate the effect of root canal preparation with single-file reciprocating systems at different working lengths on the development of apical microcracks using micro-computed tomographic (micro-CT) imaging. Forty extracted human mandibular incisors were randomly assigned to 4 groups (n=10) according to the systems and working length used to prepare the root canals: Group A - WaveOne Gold at apical foramen (AF), Group B - WaveOne Gold 1 mm short of the AF (AF-1 mm), Group C - Unicone (AF) and Group D - Unicone (AF-1 mm). Micro-CT scanning was performed before and after root canal preparation at an isotropic resolution of 14 µm. Then, three examiners assessed the cross-sectional images generated to detect microcracks in the apical portion of the roots. Apical microcracks were visualized in 3, 1, 1, and 3 specimens in groups A, B, C, and D, respectively. All these microcracks observed after root canal preparation already existed prior to instrumentation, and no new apical microcrack was detected. For all groups, the number of slices presenting microcracks after root canal preparation was the same as before canal preparation. Root canal preparation with WaveOne Gold and Unicone, regardless of the working length, was not associated with apical microcrack formation.
Characterization of ovarian follicular dynamics in dromedary camels (Camelus dromedarius).
Manjunatha, B M; Pratap, N; Al-Bulushi, Samir; Hago, B E
2012-09-15
Ovarian follicular dynamics was monitored by transrectal ultrasonography, for a period of 60 to 90 days, and its correlation with plasma estradiol-17β (E2) and progesterone (P4) were studied in seventeen, multiparous, non-lactating, 12 to 20-year-old dromedary camels. The average number of follicles recruited (12.77 ± 0.93) in each wave between animals varied (P < 0.001). The number of follicles recruited during different follicular waves was highly repeatable (0.95) within individual animals. The growth and mature phase periods of the dominant follicle (DF) were 6.10 ± 0.15 and 10.20 ± 0.47 days, respectively with a linear growth rate of 1.17 ± 0.02 mm/day between Day 0 and 10 of the follicular wave. There was an inverse relationship between the diameter of the largest DF and number of follicles (r = -0.95, P < 0.001). The DF development did not regularly alternate between the ovaries and the incidence of codominance was 45%. The mean maximum diameter of DF during its mature phase was 27.30 ± 0.78 mm and oversized follicle was 38.43 ± 1.41 mm. In 73.3% waves, the DF continued its growth for a period of 10.64 ± 1.53 days even after losing its dominance and developed into oversized follicle. The duration of the regression phase of DF and oversized follicle were 24.71 ± 3.79 and 18.50 ± 2.23 days. The mean duration of a complete follicular wave was 47.11 ± 2.94 days with an interwave interval (IWI) of 16.36 ± 0.37 days. The IWI within an individual was repeatable (0.88) and between the animals was variable (P < 0.001). Plasma E2 concentration profiles showed a wave like pattern. The peak plasma E2 concentrations were attained approximately 12 days after beginning of the growth phase, when the largest DF grew to a diameter of 18.7 mm. Plasma concentration of P4 was below 1.0 ng/mL in 85% of waves and above 1.0 ng/mL in 15% of the waves for a period of 3 to 6 days in the absence of spontaneous ovulation. It is concluded that ovarian follicular development and plasma E2 concentrations occurs in a wave like pattern in dromedary camels and the IWI and follicle numbers recruited per wave are variable between the animals and repeatable within an individual animal. Copyright © 2012 Elsevier Inc. All rights reserved.
Effect of dark chocolate on arterial function in healthy individuals.
Vlachopoulos, Charalambos; Aznaouridis, Konstantinos; Alexopoulos, Nikolaos; Economou, Emmanuel; Andreadou, Ioanna; Stefanadis, Christodoulos
2005-06-01
Epidemiologic studies suggest that high flavonoid intake confers a benefit on cardiovascular outcome. Endothelial function, arterial stiffness, and wave reflections are important determinants of cardiovascular performance and are predictors of cardiovascular risk. The effect of flavonoid-rich dark chocolate (100 g) on endothelial function, aortic stiffness, wave reflections, and oxidant status were studied for 3 h in 17 young healthy volunteers according to a randomized, single-blind, sham procedure-controlled, cross-over protocol. Flow-mediated dilation (FMD) of the brachial artery, aortic augmentation index (AIx), and carotid-femoral pulse wave velocity (PWV) were used as measures of endothelial function, wave reflections, and aortic stiffness, respectively. Plasma oxidant status was evaluated with measurement of plasma malondialdehyde (MDA) and total antioxidant capacity (TAC). Chocolate led to a significant increase in resting and hyperemic brachial artery diameter throughout the study (maximum increase by 0.15 mm and 0.18 mm, respectively, P < .001 for both). The FMD increased significantly at 60 min (absolute increase 1.43%, P < .05). The AIx was significantly decreased with chocolate throughout the study (maximum absolute decrease 7.8%, P < .001), indicating a decrease in wave reflections, whereas PWV did not change to a significant extent. Plasma MDA and TAC did not change after chocolate, indicating no alterations in plasma oxidant status. Our study shows for the first time that consumption of dark chocolate acutely decreases wave reflections, that it does not affect aortic stiffness, and that it may exert a beneficial effect on endothelial function in healthy adults. Chocolate consumption may exert a protective effect on the cardiovascular system; further studies are warranted to assess any long-term effects.
Tidal impact on geophysical fields registed in GPO "Mikhnevo" area
NASA Astrophysics Data System (ADS)
Vinogradov, Evgeny; Besedina, Alina; Gorbunova, Ella
2013-04-01
Geophysical observatory "Mikhnevo" is situated in the centre of Russian Plate and characterized with stable response to lunisolar tides. Since February 2008, regular precision measurements of groundwater level are carried out in a measurement well synchronously with atmospheric pressure measurements (sampling interval is 1 s, the measurement accuracy is 0.1 mm for the level and 0.1 gPa for atmospheric pressure). According to the results of hydrogeological sampling, the pressure head in the aquifer under study is 8.1 m, its transmissivity is 3.0 m2/day, hydraulic conductivity was 0.13 m/day, the pressure conductivity factor and elastic water yield are 1.3 × 104 m2/day and 2.3 × 10-4, respectively. Using flow measurements and telemetry of the open part of bore hole, major intervals of water inflow were detected at depths of 92-94 m and 99-100 m. Rock transmissivity in the fissure-conducting zone increases to 5.0 m2/day. Based on tidal component analysis in the filtered hydrogeological data, five main kinds of tidal waves were extracted (?1, ?2, Q1, ?1 and 2). STS-2 and KSESh-R seismometers registration range extension made it possible to extract tidal waves from Z-component of ground displacement. Similar methodology of data processing was used for tides analysis in hydrogeological, seismic and barometric data. It should be noted that barometric component extracted from water level variations can, in some cases, lead to misrepresentation of the data in frequency range under consideration. That is why two variants of data were analysed - with included and excluded barometric component. To extract tides from water level variations, long-period and barometric components were excluded from original precise monitoring datum. Data series obtained in this way were used for monthly spectrum realization, which, in turn, allowed finding out amplitudes of main tidal waves ?1, ?1 and 2. The most significant luni-solar ?1 wave annual variations cycle correlates with hydraulic head. Maximum amplitudes of ?1 wave for the whole 4 year observation period are observed then the ground-water level is high. Variation range of ?1 wave amplitude is stable and reaches 2.9 mm per year. Most significant variations take place in spring-summer period. Main lunar waves amplitude variations do not exceed 1.1 mm. The phase shift increase between luni-solar tides response in seismic and hydrogeological data was found. Diurnal O1 wave variations analysis should be done with barometric component excluded datum because of amplitude difference. During period under consideration M2 and K1 waves amplitudes are comparable and about 4.1 mm, O1 amplitude is on it minimum about 3.7 mm. Maximum diurnal and semi-diurnal wave amplitudes of water level variations confine with minimum values of luni-solar attraction. On the contrary on the same periods we can see decrease of ground displacement amplitudes as a result of tidal forces. Main tidal waves were extracted from atmospheric pressure datum too. Luni-solar K1 wave has the most amplitude there and exceeds O1 and M2 values 5-7 times.
High Power Squeeze Type Phase Shifter at W-Band
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hill, Marc E
2000-09-28
We describe the design, fabrication and bench-study of a mm-wave phase-shifter employed as a high power recirculator for a traveling wave resonator circuit. The OFE copper phase shifter was prepared by electro-discharge machining. Measured phase-shifter characteristics are presented and compared with theory. The phase-shifter was employed in a traveling wave circuit at 91.4 GHz with circulating power of 0.2 MW and subjected to fields greater than 10 MV/m without evidence of breakdown.
An Off-Grid Turbo Channel Estimation Algorithm for Millimeter Wave Communications.
Han, Lingyi; Peng, Yuexing; Wang, Peng; Li, Yonghui
2016-09-22
The bandwidth shortage has motivated the exploration of the millimeter wave (mmWave) frequency spectrum for future communication networks. To compensate for the severe propagation attenuation in the mmWave band, massive antenna arrays can be adopted at both the transmitter and receiver to provide large array gains via directional beamforming. To achieve such array gains, channel estimation (CE) with high resolution and low latency is of great importance for mmWave communications. However, classic super-resolution subspace CE methods such as multiple signal classification (MUSIC) and estimation of signal parameters via rotation invariant technique (ESPRIT) cannot be applied here due to RF chain constraints. In this paper, an enhanced CE algorithm is developed for the off-grid problem when quantizing the angles of mmWave channel in the spatial domain where off-grid problem refers to the scenario that angles do not lie on the quantization grids with high probability, and it results in power leakage and severe reduction of the CE performance. A new model is first proposed to formulate the off-grid problem. The new model divides the continuously-distributed angle into a quantized discrete grid part, referred to as the integral grid angle, and an offset part, termed fractional off-grid angle. Accordingly, an iterative off-grid turbo CE (IOTCE) algorithm is proposed to renew and upgrade the CE between the integral grid part and the fractional off-grid part under the Turbo principle. By fully exploiting the sparse structure of mmWave channels, the integral grid part is estimated by a soft-decoding based compressed sensing (CS) method called improved turbo compressed channel sensing (ITCCS). It iteratively updates the soft information between the linear minimum mean square error (LMMSE) estimator and the sparsity combiner. Monte Carlo simulations are presented to evaluate the performance of the proposed method, and the results show that it enhances the angle detection resolution greatly.
Compact terahertz wave polarization beam splitter using photonic crystal.
Mo, Guo-Qiang; Li, Jiu-Sheng
2016-09-01
Electromagnetic polarization conveys valuable information for signal processing. Manipulation of a terahertz wave polarization state exhibits tremendous potential in developing applications of terahertz science and technology. We propose an approach to efficiently split transverse-electric and transverse-magnetic polarized terahertz waves into different propagation directions over the frequency range from 0.9998 to 1.0007 THz. Both the plane wave expansion method and the finite-difference time-domain method are used to calculate and analyze the transmission characteristics of the proposed device. The present device is very compact and the total size is 1.02 mm×0.99 mm. This polarization beam splitter performance indicates that the structure has a potential application for forthcoming terahertz-wave integrated circuit fields.
NASA Astrophysics Data System (ADS)
Rappaport, Theodore S.; Xing, Yunchou; MacCartney, George R.; Molisch, Andreas F.; Mellios, Evangelos; Zhang, Jianhua
2017-12-01
This paper provides an overview of the features of fifth generation (5G) wireless communication systems now being developed for use in the millimeter wave (mmWave) frequency bands. Early results and key concepts of 5G networks are presented, and the channel modeling efforts of many international groups for both licensed and unlicensed applications are described here. Propagation parameters and channel models for understanding mmWave propagation, such as line-of-sight (LOS) probabilities, large-scale path loss, and building penetration loss, as modeled by various standardization bodies, are compared over the 0.5-100 GHz range.
Evidence of Biot Slow Waves in Electroseismic Measurementss on Laboratory-Scale
NASA Astrophysics Data System (ADS)
Devi, M. S.
2015-12-01
Electroseismic methods which are the opposite of seismo-electric methods have only been little investigated up to now especially in the near surface scale. These methods can generate the solid-fluid relative movement induced by the electric potential in fluid-filled porous media. These methods are the response of electro-osmosis due to the presence of the electrical double layer. Laboratory experiments and numerical simulations of electroseismic studies have been performed. Electroseismic measurements conducted in micro glass beads saturated with demineralized water. Pair of 37 x 37 mm square aluminium grids with 2 mm of aperture and 4 mm of spacing is used as the electric dipole that connected to the electric power source with the voltage output 150 V. A laser doppler vibrometer is the system used to measure velocity of vibrating objects during measurements by placing a line of reflective paper on the surface of media that scattered back a helium-neon laser. The results in homogeneous media shows that the compressional waves induced by an electric signal. We confirm that the results are not the effects of thermal expansion. We also noticed that there are two kinds of the compressional waves are recorded: fast and slow P-waves. The latter, Biot slow waves, indicate the dominant amplitude. Moreover, we found that the transition frequency (ωc) of Biot slow waves depends on mechanical parameters such as porosity and permeability. The ωc is not affected when varying conductivity of the fluid from 25 - 320 μS/cm, although the amplitude slightly changed. For the results in two layer media by placing a sandstone as a top layer shows that a large amount of transmission seismic waves (apparently as Biot slow waves) rather than converted electromagnetic-to-seismic waves. These properties have also been simulated with full waveform numerical simulations relying on Pride's (1994) using our computer code (Garambois & Dietrich, 2002). If it is true that the electric source in the safe voltage range generates seismic waves dominantly, it may be a reason of electro-osmosis dewatering technique to transport liquids. And this source may be used an alternative as a seismic source in geophysical exploration.
Unsteady self-sustained detonation in flake aluminum dust/air mixtures
NASA Astrophysics Data System (ADS)
Liu, Q.; Li, S.; Huang, J.; Zhang, Y.
2017-07-01
Self-sustained detonation waves in flake aluminum dust/air mixtures have been studied in a tube of diameter 199 mm and length 32.4 m. A pressure sensor array of 32 sensors mounted around certain circumferences of the tube was used to measure the shape of the detonation front in the circumferential direction and pressure histories of the detonation wave. A two-head spin detonation wave front was observed for the aluminum dust/air mixtures, and the cellular structure resulting from the spinning movement of the triple point was analyzed. The variations in velocity and overpressure of the detonation wave with propagation distance in a cell were studied. The interactions of waves in triple-point configurations were analyzed and the flow-field parameters were calculated. Three types of triple-point configuration have been found in the wave front of the detonation wave of an aluminum dust/air mixture. Both strong and weak transverse waves exist in the unstable self-sustained detonation wave.
Experimental study on the pressure wave propagation in the artificial arterial tree in brain
NASA Astrophysics Data System (ADS)
Shimada, Shinya; Tsurusaki, Ryo; Iwase, Fumiaki; Matsukawa, Mami; Lagrée, Pierre-Yves
2018-07-01
A pulse wave measurement is effective for the early detection of arteriosclerosis. The pulse wave consists of incident and reflected waves. The reflected wave of the pulse wave measured at the left common carotid artery seems to originate from the vascular beds in the brain. The aim of this study is to know if the reflected waves from the occlusions in cerebral arteries can affect the pulse waveform. The artificial arterial tree in the brain was therefore fabricated using polyurethane tubes. After investigating the effects of the bifurcation angle on the pulse waveform, we attempted to confirm whether the reflected waves from occlusions in the artificial arterial tree in the brain can be experimentally measured at the left common carotid artery. Results indicate that the bifurcation angle did not affect the pulse waveform, and that the reflected wave from an occlusion with a diameter of more than 1 mm in the brain could be observed.
A standing wave linear ultrasonic motor operating in in-plane expanding and bending modes.
Chen, Zhijiang; Li, Xiaotian; Ci, Penghong; Liu, Guoxi; Dong, Shuxiang
2015-03-01
A novel standing wave linear ultrasonic motor operating in in-plane expanding and bending modes was proposed in this study. The stator (or actuator) of the linear motor was made of a simple single Lead Zirconate Titanate (PZT) ceramic square plate (15 × 15 × 2 mm(3)) with a circular hole (D = 6.7 mm) in the center. The geometric parameters of the stator were computed with the finite element analysis to produce in-plane bi-mode standing wave vibration. The calculated results predicted that a driving tip attached at midpoint of one edge of the stator can produce two orthogonal, approximate straight-line trajectories, which can be used to move a slider in linear motion via frictional forces in forward or reverse direction. The investigations showed that the proposed linear motor can produce a six times higher power density than that of a previously reported square plate motor.
Elastic Nonlinear Response in Granular Media Under Resonance Conditions
NASA Astrophysics Data System (ADS)
Jia, X.; Johnson, P. A.
2004-12-01
We are studying the elastic linear and nonlinear behavior of granular media using dynamic wave methods. In the work presented here, our goal is to quantify the elastic nonlinear response by applying wave resonance. Resonance studies are desirable because they provide the means to easily study amplitude dependencies of elastic nonlinear behavior and thus to characterize the physical nature of the elastic nonlinearity. This work has implications for a variety of topics, in particular, the in situ nonlinear response of surface sediments. For this work we constructed an experimental cell in which high sensitivity dynamic resonance studies were conducted using granular media under controlled effective pressure. We limit our studies here to bulk modes but have the capability to employ shear waves as well. The granular media are composed of glass beads held under pressure by a piston, while applying resonance waves from transducers as both the excitation and the material probe. The container is closed with two fitted pistons and a normal load is applied to the granular sample across the top piston. Force and displacement are measured directly. Resonant frequency sweeps with frequencies corresponding to the fundamental bulk mode are applied to the longitudinal source transducer. The pore pressure in the system is 1 atm. The glass beads used in our experiments are of diameter 0.5 mm, randomly deposited in a duralumin cylinder of diameter 30 mm and height of 15 mm. This corresponds to a granular skeleton acoustic wave velocity of v ª 750m/s under 50 N of force [0.07 Mpa]. The loaded system gives fundamental mode resonances in the audio frequency band at half a wavelength where resonance frequency is effective-pressure dependent. The volume fraction of glass beads thus obtained is found to be 0.63 ± 0.01. Plane-wave generating and detecting transducers of diameter 30 mm are placed on axis at the top and bottom of the cylindrical container in direct contact with the glass beads. The wave signals are detected using a lock-in amplifier, and frequency and amplitude are recorded on computer. Drive frequency is swept from below to above the resonance mode. A typical frequency sweep is 3 kHz in width with a frequency sampling of 6 Hz. Frequency sweeps are applied at progressively increasing drive voltages to test for nonlinear-dynamical induced modulus softening. The resonance frequency at peak amplitude corresponds directly to modulus. We find significant elastic nonlinearity at all effective pressures, manifest by the fundamental-mode resonance curves decreasing progressively, at progressively increasing drive level. This is equivalent to progressive material softening with wave amplitude, meaning the wavespeed and modulus diminish. The wave dissipation simultaneously increases (Johnson and Sutin 2004). For example, at 0.11 Mpa effective pressure the observed change in resonance frequency of about 2.6% corresponds to a material bulk modulus decrease of about 5.2%. Strain amplitudes are 10-7-10-6. Thus, we would predict that surface sediments should have significant elastic nonlinear response beginning at about 10-6 strain amplitude. reference: Johnson, P. and A. Sutin, Slow dynamics in diverse solids, J. Acoust. Soc Am., in press (2004).
Manjunatha, B M; Al-Bulushi, Samir; Pratap, N
2015-09-01
This study was conducted to develop a hormone protocol that precisely synchronises follicular development for a timed breeding (TB) programme in dromedary camels. To examine the effect of GnRH treatment at four known stages of follicular development, animals were treated with GnRH when the largest follicle of the wave was 4-7, 8-11, 12-17 and 18-27 mm in diameter. Transrectal ultrasonography was carried out daily up to 20 days after treatment. A hormone protocol (FWsynch) for the synchronisation of follicular wave and TB consisting of GnRH-1 (GnRH) on Day 0, PG-1 (PGF2α) on Day 7, GnRH-2 on Day 10 and PG-2 on Day 17 was initiated at four known stages of follicular development. Ovarian structures were monitored by ultrasonography. The FWsynch protocol was initiated at random stages of follicle development and animals were bred by natural mating at a fixed time at the research facility and in field. The pregnancy was diagnosed by ultrasonography. GnRH treatment in animals with a dominant follicle (DF) of ≥ 11 mm in diameter resulted in synchronous new follicular wave emergence, whereas in animals with a DF ≤ 10 mm, the treatment did not alter the development of the existing follicular wave. The FWsynch protocol was effective in synchronising the follicular wave for TB irrespective of the stage of follicular development at the beginning of the protocol. TB using FWsynch protocol resulted in a pregnancy rate of 60.2% in a research facility and 53.6% and 45.6% in normal and infertile camels respectively under field conditions. Copyright © 2015 Elsevier B.V. All rights reserved.
Furia, John P
2008-03-01
High-energy extracorporeal shock wave therapy has been shown to be an effective treatment for chronic insertional Achilles tendinopathy. The results of high-energy shock wave therapy for chronic noninsertional Achilles tendinopathy have not been determined. Shock wave therapy is an effective treatment for noninsertional Achilles tendinopathy. Case control study; Level of evidence, 3. Thirty-four patients with chronic noninsertional Achilles tendinopathy were treated with a single dose of high-energy shock wave therapy (shock wave therapy group; 3000 shocks; 0.21 mJ/mm(2); total energy flux density, 604 mJ/mm(2)). Thirty-four patients with chronic noninsertional Achilles tendinopathy were treated not with shock wave therapy but with additional forms of nonoperative therapy (control group). All shock wave therapy procedures were performed using regional anesthesia. Evaluation was by change in visual analog score and by Roles and Maudsley score. One month, 3 months, and 12 months after treatment, the mean visual analog scores for the control and shock wave therapy groups were 8.4 and 4.4 (P < .001), 6.5 and 2.9 (P < .001), and 5.6 and 2.2 (P < .001), respectively. At final follow-up, the number of excellent, good, fair, and poor results for the shock wave therapy and control groups were 12 and 0 (P < .001), 17 and 9 (P < .001), 5 and 17 (P < .001), and 0 and 8 (P < .001), respectively. A chi(2) analysis revealed that the percentage of patients with excellent ("1") or good ("2") Roles and Maudsley scores, that is, successful results, 12 months after treatment was statistically greater in the shock wave therapy group than in the control group (P < .001). Shock wave therapy is an effective treatment for chronic noninsertional Achilles tendinopathy.
Dynamic beam steering at submm- and mm-wave frequencies using an optically controlled lens antenna
NASA Astrophysics Data System (ADS)
Gallacher, T. F.; Søndenâ, R.; Robertson, D. A.; Smith, G. M.
2013-05-01
We present details of our work which has been focused on improving the efficiency and scan rate of the photo-injected Fresnel zone plate antenna (piFZPA) technique which utilizes commercially available visible display technologies. This approach presents a viable low-cost solution for non-mechanical beam steering, suitable for many applications at (sub) mm-wave frequencies that require rapid beam steering capabilities in order to meet their technological goals, such as imaging, surveillance, and remote sensing. This method has the advantage of being comparatively low-cost, is based on a simple and flexible architecture, enabling rapid and precise arbitrary beam forming, and which is scalable to higher frame-rates and higher submm-wave frequencies. We discuss the various optimization stages of a range of piFZPA designs that implement fast visible projection displays, enabling up to 30,000 beams per second. We also outline the suitability of this technology across mm-wave and submm-wave frequencies as a low-cost and simple solution for dynamic optoelectronic beam steering.
NASA Astrophysics Data System (ADS)
Jang, Sang-Hoon; Hwang, Se-Joon; Park, Sang-Ki; Choi, Kap-Seung; Kim, Hyung-Man
2012-06-01
Developing an effective method of reducing nitrogen oxide emissions is an important goal in diesel engine research. The use of cooled exhaust gas recirculation has been considered one of the most effective techniques of reducing nitrogen oxide. However, since the combustion characteristics in a diesel engine involves high temperature and load, the amount of particulate matter emission tends to increase, and there is a trade-off between the amount of nitrogen oxide and particulate matter emissions. In the present study, engine dynamometer experiments are performed to investigate the effects of particulate matter fouling on the heat exchange characteristics of wave fin type exhaust gas recirculation coolers that have four cases of two wave pitch and three fin pitch lengths. To optimize the fin and wave pitches of the EGR cooler, the exhaust gas temperature, pressure drop and heat exchange effectiveness are compared. The experimental results show that the exhaust gas recirculation cooler with a fin pitch of 3.6 mm and a wave pitch of 8.8 mm exhibits better heat exchange characteristics and smaller particulate matter fouling effect than the other coolers.
A Dynamic Analysis of Hydrodynamic Wave Journal Bearings
NASA Technical Reports Server (NTRS)
Ene, Nicoleta M.; Dimofte, Florin; Keith, Theo G.
2008-01-01
The purpose of this paper is to study the dynamic behavior of a three-wave journal bearing using a transient approach. The transient analysis permits the determination of the rotor behavior after the fractional frequency whirl appears. The journal trajectory is determined by solving a set of nonlinear equations of motion using the Runge-Katta method. The fluid film forces are computed by integrating the transient Reynolds equation at each time step location of the shaft with respect to the bearing. Because of the large values of the rotational speeds, turbulent effects were included in the computations. The influence of the temperature on the viscosity was also considered. Numerical results were compared to experimenta1 results obtained at the NASA Glenn Research Center. Comparisons of the theoretical results with experimental data were found to be in good agreement. The numerical and experimental results showed that the fluid film of a three-wave journal bearing having a diameter of 30 mm, a length of 27 mm, and a wave amplitude ratio greater than 0.15 is stable even at rotational speeds of 60,000 RPM. For lower wave amplitude ratios, the threshold speed at which the fluid film becomes unstable depends on the wave amplitude and on the supply pocket pressure. Even if the fluid film is unstable, the wave bearing maintains the whirl orbit inside the bearing clearance.
Waibel, Jill S; Rudnick, Ashley; Nousari, Carlos; Bhanusali, Dhaval G
2016-01-01
Topical drug delivery is the foundation of all dermatological therapy. Laser-assisted drug delivery (LAD) using fractional ablative laser is an evolving modality that may allow for a greater precise depth of penetration by existing topical medications, as well as more efficient transcutaneous delivery of large drug molecules. Additional studies need to be performed using energy-driven methods that may enhance drug delivery in a synergistic manner. Processes such as iontophoresis, electroporation, sonophoresis, and the use of photomechanical waves aid in penetration. This study evaluated in vivo if there is increased efficacy of fractional CO2 ablative laser with immediate acoustic pressure wave device. Five patients were treated and biopsied at 4 treatment sites: 1) topically applied aminolevulinic acid (ALA) alone; 2) fractional ablative CO2 laser and topical ALA alone; 3) fractional ablative CO2 laser and transdermal acoustic pressure wave device delivery system; and 4) topical ALA with transdermal delivery system. The comparison of the difference in the magnitude of diffusion with both lateral spread of ALA and depth diffusion of ALA was measured by fluorescence microscopy. For fractional ablative CO2 laser, ALA, and transdermal acoustic pressure wave device, the protoporphyrin IX lateral fluorescence was 0.024 mm on average vs 0.0084 mm for fractional ablative CO2 laser and ALA alone. The diffusion for the acoustic pressure wave device was an order of magnitude greater. We found that our combined approach of fractional ablative CO2 laser paired with the transdermal acoustic pressure wave device increased the depth of penetration of ALA.
Shock Initiation of Secondary Explosives by MicroSlapper
NASA Astrophysics Data System (ADS)
Mendes, Ricardo; Campos, Jose; Plaksin, Igor; Ribeiro, Jose
2001-06-01
Using the well known Exploding Foil Initiator (EFI) also called slapper detonator the shock to Detonation Wave (DW) transition in a low dense secondary explosive like PETN and RDX is presented in this study. The EFI formed by a capacitor with capacity up to 0.2μF charged until 3kV was used to burst copper bridges with 0.3x0.3mm and 0.4x0.3mm with 5μm of thickness, and to accelerate Kapton flyer plates with 25μm of thickness until 5mm/μs. The process of Shock to Detonation Transition (SDT) in explosive samples with 5mm of diameter by 10mm of height was characterized by an optical method based on 64 optical fibbers ribbon (250mm of diameter each fibber) connected to a fast electronic streak camera. The obtained results, (x,t) diagrams, with 1ns resolution, show continuously the shock to detonation transition regime and allowed the evaluation of the detonation velocity and the detonation wave front curvature. In that regime DW propagation presents the oscillations in detonation velocity. The results also show the influence of the flyer plate velocity and the initial density of the explosive sample in the process of SDT and front oscillations.
NASA Astrophysics Data System (ADS)
Shrestha, Ranjit; Kim, Wontae
2017-06-01
This paper investigates the possibilities of evaluating non-uniform coating thickness using thermal wave imaging method. A comparative study of pulsed thermography (PT) and lock-in thermography (LIT) based on evaluating the accuracy of predicted coating thickness is presented. In this study, a transient thermal finite element model was created in ANSYS 15. A single square pulse heating for PT and a sinusoidal heating at different modulation frequencies for LIT were used to stimulate the sample according to the experimental procedures. The response of thermally excited surface was recorded and data processing with Fourier transform was carried out to obtain the phase angle. Then calculated phase angle was correlated with the coating thickness. The method demonstrated potential in the evaluation of coating thickness and was successfully applied to measure the non-uniform top layers ranging from 0.1 mm to 0.6 mm; within an accuracy of 0.0003-0.0023 mm for PT and 0.0003-0.0067 mm for LIT. The simulation model enabled a better understanding of PT and LIT and provided a means of establishing the required experimental set-up parameters. This also led to optimization of experimental configurations, thus limiting the number of physical tests necessary.
Laboratory Investigation of the Effect of Water-Saturation on Seismic Wave Dispersion in Carbonates
NASA Astrophysics Data System (ADS)
Li, W.; Pyrak-Nolte, L. J.
2009-12-01
In subsurface rock, fluid content changes with time through natural causes or because of human interactions, such as extraction or sequestration of fluids. The ability to monitor, seismically, fluid migration in the subsurface requires an understanding of the effects that the degree of saturation and spatial distribution of fluids have on wave propagation in rock. In this study, we find that the seismic dispersion of a dry carbonate rock can be masked by saturating the sample. We used a laboratory mini-seismic array to monitor fluid invasion and withdrawal in a carbonate rock with fabric-controlled layering. Experiments were performed on prismatic samples of Austin Chalk measuring 50mm x 50mm x 100mm. The epoxy-sealed samples contained an inlet and an outlet port to enable fluid invasion/withdrawal along the long axis of the sample. Water was infused and withdrawn from the sample at a rate of 1ml/hr. The mini-seismic array consisted of a set of 12 piezoelectric contact transducers, each with a central frequency 1.0 MHz. Three compressional wave source-receiver pairs and three shear wave source-receiver pairs were used to probe along the length of the sample prior to invasion and during invasion and withdrawal of water from the sample. A pressure transducer was used to record the fluid pressure simultaneously with the full transmitted wave forms every 15-30 minutes. A wavelet analysis determined the effect of fluid invasion on velocity dispersion. We observed that the compressional wave dispersion was more sensitive to changes in saturation than the shear wave dispersion. When the sample was unsaturated, the high frequency components of the compressional wave (1.2MHz to 2MHz) had lower velocities (~ 2750m/s) than the low frequency components, which decrease monotonically from 2890 m/s for 0.2MHz to 1.2 MHz. As water infused the sample, the dispersion weakened. When the sample as fully saturated, the compressional wave velocity was frequency independent. The functional form of the dependence of the shear wave velocity on frequency is relatively constant with fluid saturation, but the magnitude of the velocity decreased (~35 m/s) with increasing saturation. From theoretical calculations, the shear modulus increased during water invasion and was independent of frequency. However, the changes in the Young’s modulus with water invasion depended on the frequency of observation. When 46.5ml was infused into the sample, the Young’s modulus interpreted from the high-frequency components (wavelength from 1.43mm to 2.4mm) increased 70%, while the modulus from the low-frequency components (wavelengths vary from 1.4cm to 3.4mm) increased between 20% and 55%. Interpreting seismic data to determine fluid saturation in rock with fabric-controlled layering requires an understanding of the seismic dispersion properties of the rock in addition to the ability of fluids on alter or mask the dispersion. Acknowledgments: The authors wish to acknowledge support of this work by the Geosciences Research Program, Office of Basic Energy Sciences US Department of Energy (DEFG02-97ER14785 08), by Exxon Mobil Upstream Research Company and the GeoMathematical Imaging Group at Purdue University.
Effect of Calcifications on Breast Ultrasound Shear Wave Elastography: An Investigational Study.
Gregory, Adriana; Mehrmohammadi, Mohammad; Denis, Max; Bayat, Mahdi; Stan, Daniela L; Fatemi, Mostafa; Alizad, Azra
2015-01-01
To investigate the effects of macrocalcifications and clustered microcalcifications associated with benign breast masses on shear wave elastography (SWE). SuperSonic Imagine (SSI) and comb-push ultrasound shear elastography (CUSE) were performed on three sets of phantoms to investigate how calcifications of different sizes and distributions influence measured elasticity. To demonstrate the effect in vivo, three female patients with benign breast masses associated with mammographically-identified calcifications were evaluated by CUSE. Apparent maximum elasticity (Emax) estimates resulting from individual macrocalcifications (with diameters of 2mm, 3mm, 5mm, 6mm, 9mm, 11mm, and 15mm) showed values over 50 kPa for all cases, which represents more than 100% increase over background (~21kPa). We considered a 2cm-diameter circular region of interest for all phantom experiments. Mean elasticity (Emean) values varied from 26 kPa to 73 kPa, depending on the macrocalcification size. Highly dense clusters of microcalcifications showed higher Emax values than clusters of microcalcification with low concentrations, but the difference in Emean values was not significant. Our results demonstrate that the presence of large isolated macrocalcifications and highly concentrated clusters of microcalcifications can introduce areas with apparent high elasticity in SWE. Considering that benign breast masses normally have significantly lower elasticity values than malignant tumors, such areas with high elasticity appearing due to presence of calcification in benign breast masses may lead to misdiagnosis.
Normal computerized Q wave measurements in healthy young athletes.
Saini, Divakar; Grober, Aaron F; Hadley, David; Froelicher, Victor
Recent Expert consensus statements have sought to decrease false positive rates of electrocardiographic abnormalities requiring further evaluation when screening young athletes. These statements are largely based on traditional ECG patterns and have not considered computerized measurements. To define the normal limits for Q wave measurements from the digitally recorded ECGs of healthy young athletes. All athletes were categorized by sex and level of participation (high school, college, and professional), and underwent screening ECGs with routine pre-participation physicals, which were electronically captured and analyzed. Q wave amplitude, area and duration were recorded for athletes with Q wave amplitudes greater than 0.5mm at standard paper amplitude display (1mV/10mm). ANOVA analyses were performed to determine differences these parameters among all groups. A positive ECG was defined by our Stanford Computerized Criteria as exceeding the 99th percentile for Q wave area in 2 or more leads. Proportions testing was used to compare the Seattle Conference Q wave criteria with our data-driven criteria. 2073 athletes in total were screened. Significant differences in Q wave amplitude, duration and area were identified both by sex and level of participation. When applying our Stanford Computerized Criteria and the Seattle criteria to our cohort, two largely different groups of athletes are identified as having abnormal Q waves. Computer analysis of athletes' ECGs should be included in future studies that have greater numbers, more diversity and adequate end points. Copyright © 2017 Elsevier Inc. All rights reserved.
Barnes, K; Lanz, O; Werre, S; Clapp, K; Gilley, R
2015-01-01
To compare optical values in the osteotomy gap created after a tibial tuberosity advancement (TTA) treated with autogenous cancellous bone graft, extracorporeal shock wave therapy, a combination of autogenous cancellous bone graft and extracorporeal shock wave therapy, and absence of both autogenous cancellous bone graft and extracorporeal shock wave therapy using densitometry. Dogs that were presented for surgical repair of a cranial cruciate ligament rupture were randomly assigned to one of four groups: TTA with autogenous cancellous bone graft (TTA-G), TTA with autogenous cancellous bone graft and extracorporeal shock wave therapy (TTA-GS), TTA with extracorporeal shock wave therapy (TTA-S), and TTA with no additional therapy (TTA-O). Mediolateral radiographs at zero, four and eight weeks after surgery were evaluated to compare healing of the osteotomy gap via densitometry. An analysis of variance was used to compare the densitometric values between groups. At four weeks after surgery, a significant difference in osteotomy gap density was noted between TTA-GS (8.4 millimetres of aluminium equivalent [mmAleq]) and TTA-S (6.1 mmAleq), and between TTA-GS (8.4 mmAleq) and TTA-O (6.4 mmAleq). There were no significant differences noted between any groups at the eight week re-evaluation. There were no significant differences in the osteotomy gap density at eight weeks after surgery regardless of the treatment modality used. The combination of autogenous cancellous bone graft and extracorporeal shock wave therapy may lead to increased radiographic density of the osteotomy gap in the first four weeks after surgery. Densitometry using an aluminium step wedge is a feasible method for comparison of bone density after TTA in dogs.
Arias, Ana; Lee, Yoon H; Peters, Christine I; Gluskin, Alan H; Peters, Ove A
2014-07-01
The purpose of this pilot study in a cadaver model was to compare 2 different shaping techniques regarding the induction of dentinal microcracks. Three lower incisors from each of 6 adult human cadaver skulls were randomly distributed into 3 groups: the control group (CG, no instrumentation), the GT group (GT Profile hand files; Dentsply Tulsa Dental, Tulsa, OK), and the WO group (WaveOne; Dentsply Tulsa Dental). In the GT group, manual shaping in a crown-down sequence with GT Profile hand files was performed. In the WO group, Primary WaveOne files were used to the working length. Teeth were separated from the mandibles by careful removal of soft tissue and bone under magnification. Roots were sectioned horizontally at 3, 6, and 9 mm from the apex using a low-speed saw. Color photographs at 2 magnifications (25× and 40×) were obtained. Three blinded examiners registered the presence of microcracks (yes/no), extension (incomplete/complete), direction (buccolingual/mesiodistal), and location. Data were analyzed with chi-square tests at P < .05. Microcracks were found in 50% (CG and GT) and 66% (WO) of teeth at 3 mm, 16.6% (CG) and 33.3% (GT and WO) at 6 mm, and 16.6% in all 3 groups at 9 mm from the apex. There were no significant differences in the incidence of microcracks between all groups at 3 (P = .8), 6 (P = .8), or 9 mm (P = 1). All microcracks were incomplete, started at the pulpal wall, and had a buccolingual direction. Within the limitations of this pilot study, a relationship between the shaping techniques (GT hand and WaveOne) and the incidence of microcracks could not be shown compared with uninstrumented controls. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Custom chipset and compact module design for a 75-110 GHz laboratory signal source
NASA Astrophysics Data System (ADS)
Morgan, Matthew A.; Boyd, Tod A.; Castro, Jason J.
2016-12-01
We report on the development and characterization of a compact, full-waveguide bandwidth (WR-10) signal source for general-purpose testing of mm-wave components. The monolithic microwave integrated circuit (MMIC) based multichip module is designed for compactness and ease-of-use, especially in size-constrained test sets such as a wafer probe station. It takes as input a cm-wave continuous-wave (CW) reference and provides a factor of three frequency multiplication as well as amplification, output power adjustment, and in situ output power monitoring. It utilizes a number of custom MMIC chips such as a Schottky-diode limiter and a broadband mm-wave detector, both designed explicitly for this module, as well as custom millimeter-wave multipliers and amplifiers reported in previous papers.
Investigation of Celestial Solid Analogs
NASA Technical Reports Server (NTRS)
Sievers, A. J.
2003-01-01
Our far infrared studies of both hydrophobic and hydrophilic aerogel grains have demonstrated that the mm and sub-mm wave absorption produced by the fundamental two level systems (TLS) mechanism represents a more significant contribution for these open grain structures than for bulk amorphous silicate grains. We found that the region with the anomalous temperature dependence of the spectral index due to the TLS excitations can extend in a fluffy material up to 80 per cm, which is well beyond its typical upper limit for bulk glasses. Currently there is no theoretical explanation for this surprising result. The effects of reduced dimensionality on the optical properties of carbonaceous grains have been studied with a systematic investigation of carbon aerogels. This spectroscopic approach has permitted a more reliable determination of the single grain mass normalized absorption coefficient based on the experimentally determined characteristics of the fluffy material rather than on first principles calculations involving the bulk properties of the substance. Our finding is that the electrical connectivity of the material is the main factor affecting its far infrared absorption coefficient. Another one of the main constituents of the interstellar dust, amorphous ice, has been investigated in the mm-wave region both in the high (HDA) and low (LDA) density amorphous phases and as a function of impurities. We found that doping either phase with ionic (LiCl) or molecular (methanol) impurities decreases the difference in the mm-wave absorption coefficient between the HDA and LDA ice phases so that the HDA spectrum can be used as an analog for impure ice absorption in the far infrared spectral region.
The Diurnal Profile of Central Hemodynamics in a General Uruguayan Population.
Boggia, José; Luzardo, Leonella; Lujambio, Inés; Sottolano, Mariana; Robaina, Sebastián; Thijs, Lutgarde; Olascoaga, Alicia; Noboa, Oscar; Struijker-Boudier, Harry A; Safar, Michel E; Staessen, Jan A
2016-06-01
No previous population study assessed the diurnal profile of central arterial properties. In 167 participants (mean age, 56.1 years; 63.5% women), randomly recruited in Montevideo, Uruguay, we used the oscillometric Mobil-O-Graph 24-h PWA monitor to measure peripheral and central systolic (SBP), diastolic (DBP), and pulse (PP) pressures and central hemodynamics standardized to a heart rate of 75 bpm, including aortic pulse wave velocity, systolic augmentation (first/second peak × 100), and pressure amplification (peripheral PP/central PP). Over 24 hours, day and night, peripheral minus central differences in SBP/DBP and in PP averaged 12.2/-1.1, 14.0/-0.7, and 9.7/0.2mm Hg and 12.6, 14.7, and 9.5mm Hg, respectively (P < 0.001 except for nighttime DBP (P = 0.38)). The central-to-peripheral ratios of SBP, DBP, and PP were 0.89, 1.00, and 0.70 unadjusted, but after accounting for anthropometric characteristics decreased to 0.74, 0.97, and 0.63, respectively, with strong influence of height for SBP and DBP and of sex for PP. From day (10-20h) to nighttime (0-6h), peripheral (-10.4/-10.5 mm Hg) and central (-6.0/-11.3mm Hg) SBP/DBP, pulse wave velocity (-0.7 m/s) and pressure amplification (-0.05) decreased (P < 0.001), whereas central PP (+5.3mm Hg) and systolic augmentation (+2.3%) increased (P < 0.001). The diurnal rhythm of central pressure runs in parallel with that of peripheral pressure, but the nocturnal fall in SBP is smaller centrally than peripherally. pulse wave velocity, systolic augmentation, and pressure amplification loop through the day with high pulse wave velocity and pressure amplification but low systolic augmentation in the evening and opposite trends in the morning. © American Journal of Hypertension, Ltd 2015. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Wave Absorber with Fine Weatherability for Improving ETC Environment
NASA Astrophysics Data System (ADS)
Miura, Yu; Matsumoto, Kouta; Okada, Osamu; Hashimoto, Osamu
Wave absorber of rubber sheet containing natural rubber and EPDM is designed, fabricated and measured for improving ETC environment. As a result, proposed absorption material has fine weatherability and wave absorption satisfied with ETC standard can be realized theoretically before and after the weatherability test if the thickness of absorber is fabricated at the ranging from 2.26mm to 2.52mm. Moreover, absorber sheet sample based on theoretical values is fabricated and are measured. As a result, 20dB or more is also confirmed at the incident angle ranging from 5 to 55 degrees experimentally. Therefore, the wave absorber with fine weatherability being satisfied with ETC standard can be realized.
NASA Astrophysics Data System (ADS)
Petito, F. C.; Wentworth, E. W.
1980-05-01
Recently there has been much interest expressed to determine the ability of millimeter wave radar to perform target acquisition during degraded visibility conditions. In this regard, one of the primary issues of concern has been the potential of high-explosive artillery barrages to obscure the battlefield from millimeter wave radar systems. To address this issue 95 GHz millimeter wave radar measurements were conducted during the Dusty Infrared Test 2 (DIRT 2). This test was held at White Sands Missile Range, NM, 18-28 July 1979. Millimeter wave transmission and backscatter measurements were performed during singular live firings and static detonations of 155 mm and 105 mm high-explosive artillery rounds in addition to static detonations of C-4 explosives. A brief description of the millimeter wave portion of the test and instrumentation is given. The data along with some preliminary conclusions are presented.
NASA Astrophysics Data System (ADS)
Wu, Peng; Ma, Jianxin
2017-03-01
We have proposed and demonstrated a scheme to generate a frequency-sextupling amplitude shift keying (ASK)-single sideband optical millimeter (mm)-wave signal with high dispersion tolerance based on an optical phase modulator (PM) by ably using the-4th-order and +2nd-order sidebands of the optical modulation. The ASK radio frequency signal, superposed by a local oscillator with the same frequency, modulates the lightwave via an optical PM with proper voltage amplitudes, the +2nd-order sideband carries the ASK signal with a constant slope while the -4th-order sideband maintains constant amplitude. These two sidebands can be abstracted by a wavelength selective switch to form a dual-tone optical mm-wave with only one tone carrying the ASK signal. As only one tone bears the ASK signal while the other tone is unmodulated, the generated dual-tone optical mm-wave signal has high dispersion tolerance.
Motion effects in multistatic millimeter-wave imaging systems
NASA Astrophysics Data System (ADS)
Schiessl, Andreas; Ahmed, Sherif Sayed; Schmidt, Lorenz-Peter
2013-10-01
At airport security checkpoints, authorities are demanding improved personnel screening devices for increased security. Active mm-wave imaging systems deliver the high quality images needed for reliable automatic detection of hidden threats. As mm-wave imaging systems assume static scenarios, motion effects caused by movement of persons during the screening procedure can degrade image quality, so very short measurement time is required. Multistatic imaging array designs and fully electronic scanning in combination with digital beamforming offer short measurement time together with high resolution and high image dynamic range, which are critical parameters for imaging systems used for passenger screening. In this paper, operational principles of such systems are explained, and the performance of the imaging systems with respect to motion within the scenarios is demonstrated using mm-wave images of different test objects and standing as well as moving persons. Electronic microwave imaging systems using multistatic sparse arrays are suitable for next generation screening systems, which will support on the move screening of passengers.
Numerical band structure calculations of plasma metamaterials
NASA Astrophysics Data System (ADS)
Pederson, Dylan; Kourtzanidis, Konstantinos; Raja, Laxminarayan
2015-09-01
Metamaterials (MM) are materials engineered to display negative macroscopic permittivity and permeability. These materials allow for designed control over electromagnetic energy flow, especially at frequencies where natural materials do not interact. Plasmas have recently found application in MM as a negative permittivity component. The permittivity of a plasma depends on its electron density, which can be controlled by an applied field. This means that plasmas can be used in MM to actively control the transmission or reflection of incident waves. This work focuses on a plasma MM geometry in which microplasmas are generated in perforations in a metal plate. We characterizethis material by its band structure, which describes its interaction with incident waves. The plasma-EM interactions are obtained by coupling Maxwell's equations to a simplified plasma momentum equation. A plasma density profile is prescribed, and its effect on the band structure is investigated. The band structure calculations are typically done for static structures, whereas our current density responds to the incident waves. The resulting band structures are compared with experimental results.
NASA Astrophysics Data System (ADS)
Washabaugh, P. D.; Hill, L. G.
2007-12-01
A dynamic crack propagating in a brittle material releases enough thermal energy to produce visible light. The dynamic fracture of even macroscopically amorphous materials becomes unsteady as the crack propagation velocity approaches the material wave-speeds. The heat generated at a crack-tip, especially as it jumps, may be a mechanism to initiate a self-sustaining reaction in an energetic material. Experiments were conducted in specimens to simulate an infinite plate for ˜10 μs. The initial specimens were 152 mm square by 6 mm thick acrylic sheets, and were fabricated to study non-steady near-wave-speed crack propagation. A variant of this specimen embedded a 25 mm×3 mm PBX 9205 pellet to explore the influence of dynamic Mode-I cracks in these materials. The crack was initiated by up to 0.24 g of Detasheet placed along a precursor 50 mm long notch, with a shield to contain the reaction products and prevent propagation along the fractured surfaces. The crack was studied by means of a streak camera and a Fourier-filter of the light reflecting off the newly minted surfaces. The sub-microsecond behavior of holes initiating, preceding and coalescing with the main crack were observed in the PMMA samples. The embedding and mechanical loading of explosives by this technique did not initiate a self-sustaining reaction in preliminary testing.
NASA Astrophysics Data System (ADS)
Washabaugh, Peter; Hill, Larry
2007-06-01
A dynamic crack propagating in a brittle material releases enough thermal energy to produce visible light. The dynamic fracture of even macroscopically amorphous materials becomes unsteady as the crack propagation velocity approaches the material wave-speeds. The heat generated at a crack-tip, especially as it jumps, may be a mechanism to initiate a self-sustaining reaction in an energetic material. Experiments were conducted in specimens to simulate an infinite plate for 20 μs. The initial specimens were 152 mm square by 6 mm thick acrylic sheets, and were fabricated to study non-steady near-wave-speed crack propagation. A variant of this specimen embedded a 25 mm x 3 mm PBX 9205 pellet to explore the influence of dynamic Mode-I cracks in these materials. The crack was initiated by up to 0.2 g of Detasheet placed along a precursor 50 mm long notch, with a shield to contain the reaction products and prevent propagation along the fractured surfaces. The crack was studied by means of a streak camera and a Fourier-filter of the light reflecting off the newly minted surfaces. The sub-microsecond behavior of holes initiating, preceding and coalescing with the main crack were observed in the PMMA samples. The embedding and mechanical loading of explosives by this technique did not initiate a self-sustaining reaction in preliminary testing.
Diastolic blood pressure-estimated left ventricular dp/dt.
Yilmaz, Hüseyin; Minareci, Kenan; Kabukçu, Mehmet; Sancaktar, Oktay
2002-02-01
Peak dp/dt is one of the best isovolumic phase indexes of the myocardial contractile state requiring invasive procedures or presence of mitral regurgitation severe enough to measure in clinical practice by Doppler echocardiography. In this study, we sought the correlation between two noninvasive methods of measurements for left ventricular dp/dt-diastolic blood pressure- (DBP) estimated and continuous-wave Doppler-derived dp/dt-min electrocardiographic/echocardiographic study to emphasize the clinical feasibility of the DBP-estimated method. Thirty-six randomized patients (27 male, 9 female; 58 +/- 8 years) with mild mitral regurgitation were enrolled in this study. DBP-estimated dp/dt was calculated from DBP minus the left ventricular end-diastolic pressure (LVEDP) over the isovolumetric contraction time (IVCT). LVEDP was assumed to be 10 mmHg for all patients. Doppler-determined left ventricular dp/dt was derived from the continuous-wave Doppler spectrum of mitral regurgitation jet by dividing the magnitude of the left ventricular atrial pressure gradient rise between 1 mm/sec-3 mm/sec of mitral regurgitant velocity signal by the time taken for this change. Left ventricular dp/dt by Doppler was 1122 +/- 303 mmHg/sec and blood pressure-estimated dp/dt was 1063 +/- 294 mmHg/sec. There was a high correlation (r = 0.97, P < 0.001) of dp/dt between the two techniques. DBP and IVCT can generate left ventricular dp/dt without invasive procedures, even in the absence of mitral regurgitation in clinical practice.
Strength and fracture of uranium, plutonium and several their alloys under shock wave loading
NASA Astrophysics Data System (ADS)
Golubev, V. K.
2012-08-01
Results on studying the spall fracture of uranium, plutonium and several their alloys under shock wave loading are presented in the paper. The problems of influence of initial temperature in a range of - 196 - 800∘C and loading time on the spall strength and failure character of uranium and two its alloys with molybdenum and both molybdenum and zirconium were studied. The results for plutonium and its alloy with gallium were obtained at a normal temperature and in a temperature range of 40-315∘C, respectively. The majority of tests were conducted with the samples in the form of disks 4 mm in thickness. They were loaded by the impact of aluminum plates 4 mm thick through a copper screen 12 mm thick serving as the cover or bottom part of a special container. The character of spall failure of materials and the damage degree of samples were observed on the longitudinal metallographic sections of recovered samples. For a concrete test temperature, the impact velocity was sequentially changed and therefore the loading conditions corresponding to the consecutive transition from microdamage nucleation up to complete macroscopic spall fracture were determined. The conditions of shock wave loading were calculated using an elastic-plastic computer program. The comparison of obtained results with the data of other researchers on the spall fracture of examined materials was conducted.
47 CFR 2.101 - Frequency and wavelength bands.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Myriametric waves B.Mam 5 LF 30 to 300 kHz Kilometric waves B.km 6 MF 300 to 3 000 kHz Hectometric waves B.hm 7 HF 3 to 30 MHz Decametric waves B.dam 8 VHF 30 to 300 MHz Metric waves B.m 9 UHF 300 to 3 000 MHz Decimetric waves B.dm 10 SHF 3 to 30 GHz Centimetric waves B.cm 11 EHF 30 to 300 GHz Millimetric waves B.mm...
47 CFR 2.101 - Frequency and wavelength bands.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Myriametric waves B.Mam 5 LF 30 to 300 kHz Kilometric waves B.km 6 MF 300 to 3 000 kHz Hectometric waves B.hm 7 HF 3 to 30 MHz Decametric waves B.dam 8 VHF 30 to 300 MHz Metric waves B.m 9 UHF 300 to 3 000 MHz Decimetric waves B.dm 10 SHF 3 to 30 GHz Centimetric waves B.cm 11 EHF 30 to 300 GHz Millimetric waves B.mm...
47 CFR 2.101 - Frequency and wavelength bands.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Myriametric waves B.Mam 5 LF 30 to 300 kHz Kilometric waves B.km 6 MF 300 to 3 000 kHz Hectometric waves B.hm 7 HF 3 to 30 MHz Decametric waves B.dam 8 VHF 30 to 300 MHz Metric waves B.m 9 UHF 300 to 3 000 MHz Decimetric waves B.dm 10 SHF 3 to 30 GHz Centimetric waves B.cm 11 EHF 30 to 300 GHz Millimetric waves B.mm...
40 MHz high-frequency ultrafast ultrasound imaging.
Huang, Chih-Chung; Chen, Pei-Yu; Peng, Po-Hsun; Lee, Po-Yang
2017-06-01
Ultrafast high-frame-rate ultrasound imaging based on coherent-plane-wave compounding has been developed for many biomedical applications. Most coherent-plane-wave compounding systems typically operate at 3-15 MHz, and the image resolution for this frequency range is not sufficient for visualizing microstructure tissues. Therefore, the purpose of this study was to implement a high-frequency ultrafast ultrasound imaging operating at 40 MHz. The plane-wave compounding imaging and conventional multifocus B-mode imaging were performed using the Field II toolbox of MATLAB in simulation study. In experiments, plane-wave compounding images were obtained from a 256 channel ultrasound research platform with a 40 MHz array transducer. All images were produced by point-spread functions and cyst phantoms. The in vivo experiment was performed from zebrafish. Since high-frequency ultrasound exhibits a lower penetration, chirp excitation was applied to increase the imaging depth in simulation. The simulation results showed that a lateral resolution of up to 66.93 μm and a contrast of up to 56.41 dB were achieved when using 75-angles plane waves in compounding imaging. The experimental results showed that a lateral resolution of up to 74.83 μm and a contrast of up to 44.62 dB were achieved when using 75-angles plane waves in compounding imaging. The dead zone and compounding noise are about 1.2 mm and 2.0 mm in depth for experimental compounding imaging, respectively. The structure of zebrafish heart was observed clearly using plane-wave compounding imaging. The use of fewer than 23 angles for compounding allowed a frame rate higher than 1000 frames per second. However, the compounding imaging exhibits a similar lateral resolution of about 72 μm as the angle of plane wave is higher than 10 angles. This study shows the highest operational frequency for ultrafast high-frame-rate ultrasound imaging. © 2017 American Association of Physicists in Medicine.
Huang, Yen-Chieh; Wang, Tsong-Dong; Lin, Yen-Hou; Lee, Ching-Han; Chuang, Ming-Yun; Lin, Yen-Yin; Lin, Fan-Yi
2011-11-21
We report forward and backward THz-wave difference frequency generations at 197 and 469 μm from a PPLN rectangular crystal rod with an aperture of 0.5 (height in z) × 0.6 (width in y) mm(2) and a length of 25 mm in x. The crystal rod appears as a waveguide for the THz waves but as a bulk material for the optical mixing waves near 1.54 μm. We measured enhancement factors of 1.6 and 1.8 for the forward and backward THz-wave output powers, respectively, from the rectangular waveguide in comparison with those from a PPLN slab waveguide of the same length, thickness, and domain period under the same pump and signal intensity of 100 MW/cm(2). © 2011 Optical Society of America
NASA Astrophysics Data System (ADS)
Sani, S.; Saad, M. H. Md; Jamaludin, N.; Ismail, M. P.; Mohd, S.; Mustapha, I.; Masenwat, N. A.; Tengku Amran, T. S.; Megat Ahmad, M. H. A.
2018-01-01
This paper discussed the design and development of a portable PC-based ultrasonic goniometer system that can be used to study material properties using ultrasonic wave. The system utilizes an ultrasonic pulse-receiver card model attached to computer notebook for signal display. A new specific software package (GoNIO) was developed to control the operation of the scanner, displaying the data and analyze characteristics of materials. System testing was carried out using samples with cubic dimension of about 10 mm x 20 mm x 30 mm. This size allows the sample to be fitted into the goniometer specimen holder and immersed in a liquid during measurement. The sample was rotated from incident angle of 0° to 90° during measurement and the amplitude reflected signals were recorded at every one degree of rotation. Immersion transducers were used to generate and receive the ultrasounds that pass through the samples. Longitudinal, shear and Rayleigh wave measurements were performed on the samples to determine the Dynamic Young’s Modulus. Results of measurements are explained and discussed.
Propagation of Axially Symmetric Detonation Waves
DOE Office of Scientific and Technical Information (OSTI.GOV)
Druce, R L; Roeske, F; Souers, P C
2002-06-26
We have studied the non-ideal propagation of detonation waves in LX-10 and in the insensitive explosive TATB. Explosively-driven, 5.8-mm-diameter, 0.125-mm-thick aluminum flyer plates were used to initiate 38-mm-diameter, hemispherical samples of LX-10 pressed to a density of 1.86 g/cm{sup 3} and of TATB at a density of 1.80 g/cm{sup 3}. The TATB powder was a grade called ultrafine (UFTATB), having an arithmetic mean particle diameter of about 8-10 {micro}m and a specific surface area of about 4.5 m{sup 2}/g. Using PMMA as a transducer, output pressure was measured at 5 discrete points on the booster using a Fabry-Perot velocimeter. Breakoutmore » time was measured on a line across the booster with a streak camera. Each of the experimental geometries was calculated using the Ignition and Growth Reactive Flow Model, the JWL++ Model and the Programmed Burn Model. Boosters at both ambient and cold (-20 C and -54 C) temperatures have been experimentally and computationally studied. A comparison of experimental and modeling results is presented.« less
Plateau Waves of Intracranial Pressure and Multimodal Brain Monitoring.
Dias, Celeste; Maia, Isabel; Cerejo, Antonio; Smielewski, Peter; Paiva, José-Artur; Czosnyka, Marek
2016-01-01
The aim of this study was to describe multimodal brain monitoring characteristics during plateau waves of intracranial pressure (ICP) in patients with head injury, using ICM+ software for continuous recording. Plateau waves consist of an abrupt elevation of ICP above 40 mmHg for 5-20 min. This is a prospective observational study of patients with head injury who were admitted to a neurocritical care unit and who developed plateau waves. We analyzed 59 plateau waves that occurred in 8 of 18 patients (44 %). At the top of plateau waves arterial blood pressure remained almost constant, but cerebral perfusion pressure, cerebral blood flow, brain tissue oxygenation, and cerebral oximetry decreased. After plateau waves, patients with a previously better autoregulation status developed hyperemia, demonstrated by an increase in cerebral blood flow and brain oxygenation. Pressure and oxygen cerebrovascular reactivity indexes (pressure reactivity index and ORxshort) increased significantly during the plateau wave as a sign of disruption of autoregulation. Bedside multimodal brain monitoring is important to characterize increases in ICP and give differential diagnoses of plateau waves, as management of this phenomenon differs from that of regular ICP.
NASA Astrophysics Data System (ADS)
Ma, Jianxin
2016-07-01
A full-duplex radio-over fiber (RoF) link scheme based on single sideband (SSB) optical millimeter (mm)-wave signal with polarization-rotated optical carrier is proposed to realize the source-free colorless base station (BS), in which a polarization beam splitter (PBS) is used to abstract part of the optical carrier for conveying the uplink data. Since the optical carrier for the uplink does not bear the downlink signal, no cross-talk from the downlink contaminates the uplink signal. The simulation results demonstrate that both down- and up-links maintain good performance. The mm-wave signal distribution network based on the proposed full duplex fiber link scheme can use the uniform source-free colorless BSs, which makes the access system very simpler.
Angeli, Timothy R; O'Grady, Gregory; Paskaranandavadivel, Niranchan; Erickson, Jonathan C; Du, Peng; Pullan, Andrew J; Bissett, Ian P
2013-01-01
Background/Aims Small intestine motility is governed by an electrical slow wave activity, and abnormal slow wave events have been associated with intestinal dysmotility. High-resolution (HR) techniques are necessary to analyze slow wave propagation, but progress has been limited by few available electrode options and laborious manual analysis. This study presents novel methods for in vivo HR mapping of small intestine slow wave activity. Methods Recordings were obtained from along the porcine small intestine using flexible printed circuit board arrays (256 electrodes; 4 mm spacing). Filtering options were compared, and analysis was automated through adaptations of the falling-edge variable-threshold (FEVT) algorithm and graphical visualization tools. Results A Savitzky-Golay filter was chosen with polynomial-order 9 and window size 1.7 seconds, which maintained 94% of slow wave amplitude, 57% of gradient and achieved a noise correction ratio of 0.083. Optimized FEVT parameters achieved 87% sensitivity and 90% positive-predictive value. Automated activation mapping and animation successfully revealed slow wave propagation patterns, and frequency, velocity, and amplitude were calculated and compared at 5 locations along the intestine (16.4 ± 0.3 cpm, 13.4 ± 1.7 mm/sec, and 43 ± 6 µV, respectively, in the proximal jejunum). Conclusions The methods developed and validated here will greatly assist small intestine HR mapping, and will enable experimental and translational work to evaluate small intestine motility in health and disease. PMID:23667749
Earth observations taken from orbiter Discovery during STS-91 mission
2016-08-24
STS091-713-061 (2-12 June 1998) --- The vertical stabilizer of the Space Shuttle Discovery runs through this Atlantic Ocean image made from its crew cabin. Many sets of internal waves are seen in the 70mm frame traveling through an area off the Atlantic coast of Nova Scotia, Canada. There are seven sets that run perpendicular to each other. Internal waves are tidally induced and travel below the surface of the ocean along a density change which occurs often around 150 feet deep. According to NASA scientists studying the STS-91 collection, the waves are visible because, as the wave action smoothes out the smaller waves on the surface, the manner in which the sun is reflected is changed.
NASA Astrophysics Data System (ADS)
Jian, Wei; Estevez, Claudio; Chowdhury, Arshad; Jia, Zhensheng; Wang, Jianxin; Yu, Jianguo; Chang, Gee-Kung
2010-12-01
This paper presents an energy-efficient Medium Access Control (MAC) protocol for very-high-throughput millimeter-wave (mm-wave) wireless sensor communication networks (VHT-MSCNs) based on hybrid multiple access techniques of frequency division multiplexing access (FDMA) and time division multiplexing access (TDMA). An energy-efficient Superframe for wireless sensor communication network employing directional mm-wave wireless access technologies is proposed for systems that require very high throughput, such as high definition video signals, for sensing, processing, transmitting, and actuating functions. Energy consumption modeling for each network element and comparisons among various multi-access technologies in term of power and MAC layer operations are investigated for evaluating the energy-efficient improvement of proposed MAC protocol.
Computational assessment of model-based wave separation using a database of virtual subjects.
Hametner, Bernhard; Schneider, Magdalena; Parragh, Stephanie; Wassertheurer, Siegfried
2017-11-07
The quantification of arterial wave reflection is an important area of interest in arterial pulse wave analysis. It can be achieved by wave separation analysis (WSA) if both the aortic pressure waveform and the aortic flow waveform are known. For better applicability, several mathematical models have been established to estimate aortic flow solely based on pressure waveforms. The aim of this study is to investigate and verify the model-based wave separation of the ARCSolver method on virtual pulse wave measurements. The study is based on an open access virtual database generated via simulations. Seven cardiac and arterial parameters were varied within physiological healthy ranges, leading to a total of 3325 virtual healthy subjects. For assessing the model-based ARCSolver method computationally, this method was used to perform WSA based on the aortic root pressure waveforms of the virtual patients. Asa reference, the values of WSA using both the pressure and flow waveforms provided by the virtual database were taken. The investigated parameters showed a good overall agreement between the model-based method and the reference. Mean differences and standard deviations were -0.05±0.02AU for characteristic impedance, -3.93±1.79mmHg for forward pressure amplitude, 1.37±1.56mmHg for backward pressure amplitude and 12.42±4.88% for reflection magnitude. The results indicate that the mathematical blood flow model of the ARCSolver method is a feasible surrogate for a measured flow waveform and provides a reasonable way to assess arterial wave reflection non-invasively in healthy subjects. Copyright © 2017 Elsevier Ltd. All rights reserved.
Nakamura, H; Suzuki, M
2007-10-01
An ideal toxicity assay should utilize multiple indexes obtained from transient changes of metabolic activities. Here, we demonstrate the possibility for a novel toxicity bioassay using the damped glycolytic oscillation phenomenon occurring in starved yeast cells. In a previous study, the phenomenon was characterized in detail. Under optimum conditions to induce the phenomenon, the wave shapes of the damped glycolytic oscillations were changed by the instantaneous addition of both glucose and chemicals and by changing the chemical concentration. We estimated the changes in the oscillation wave shapes as six indexes, i.e., the number of wave cycles, maximum amplitude, oscillation frequency, attenuation coefficient, initial peak height, and non-steady-state time. These index changes were obtained from several kinds of chemicals. The chemicals, especially those for acids (0.01-100 mM HCl and 0.01-50 mM citric acid), bases (0.001-50 mM KOH), heavy metal ions (1-1,000 mg L(-1); Cu(2+), Pb(2+), Cd(2+), Hg(2+)), respiratory inhibitors (3-500 mg L(-1) NaN(3)), dissolved oxygen removers (10-300 mg L(-1) NaSO(3)), surfactants (10-200 mg L(-1) benzalkonium chloride), and aldehyde (10-1,000 mg L(-1) acetaldehyde), showed characteristic patterns depending on each chemical and its concentration. These significant results demonstrate the possibilities of new methods for both toxicity qualification and quantification.
NASA Astrophysics Data System (ADS)
Tong, Yuan; He, Man; Zhou, Yuming; Zhong, Xi; Fan, Lidan; Huang, Tingyuan; Liao, Qiang; Wang, Yongjuan
2018-03-01
In this study, multilayer sandwich heterostructural Ti3C2Tx MXenes decorated with polypyrrole chains have been synthesized successfully via HF etching treatment and in-situ chemical oxidative polymerization approach. The hybrids were investigated as EM wave absorbers for the first time. It is found that the composites consisting of 25 wt% Ti3C2Tx/PPy hybrids in a paraffin matrix exhibit a minimum reflection loss of -49.2 dB (∼99.99% absorption) at the thickness of 3.2 mm and a maximum effective absorption bandwidth of 4.9 GHz (12.4-17.3 GHz) corresponding to an absorber thickness of 2.0 mm. Additionally, a broad effective absorption bandwidth of 13.7 GHz (4.3-18.0 GHz) can be reached up by adjusting the thickness from 1.5 to 5.0 mm. Furthermore, the highest effective absorption bandwidth of 5.7 GHz can be reached when the mass fraction is 15 wt%. The enhanced comprehensive electromagnetic wave absorption has close correlation with the well-designed heterogeneous multilayered microstructure, generated heterogeneous interfaces, conductive paths, surface functional groups, localized defects and synergistic effect between laminated Ti3C2Tx and conductive polypyrrole network, which significantly improve impedance matching and attenuation abilities. The superior absorbing performance together with strong absorption and broad bandwidth endows the Ti3C2Tx/PPy hybrids with the potential prospect to be advanced EM wave absorbers.
First measurements of the new ClO-mm-wave sounder at the Jungfraujoch Alpine Station
NASA Technical Reports Server (NTRS)
Gerber, Louis; Kaempfer, Niklaus
1994-01-01
In the last years much progress has been made in the field of the detection of stratospheric trace constituents. However, only few techniques are suitable to detect ClO, one of the key constituents in ozone depletion chemistry. One of these techniques is mm-wave radiometry. This work presents the first measurements performed by a new 204 GHz radiometer at the Jungfraujoch Alpine Station.
Song, Pengfei; Zhao, Heng; Manduca, Armando; Urban, Matthew W.; Greenleaf, James F.; Chen, Shigao
2012-01-01
Fast and accurate tissue elasticity imaging is essential in studying dynamic tissue mechanical properties. Various ultrasound shear elasticity imaging techniques have been developed in the last two decades. However, to reconstruct a full field-of-view 2D shear elasticity map, multiple data acquisitions are typically required. In this paper, a novel shear elasticity imaging technique, comb-push ultrasound shear elastography (CUSE), is introduced in which only one rapid data acquisition (less than 35 ms) is needed to reconstruct a full field-of-view 2D shear wave speed map (40 mm × 38 mm). Multiple unfocused ultrasound beams arranged in a comb pattern (comb-push) are used to generate shear waves. A directional filter is then applied upon the shear wave field to extract the left-to-right (LR) and right-to-left (RL) propagating shear waves. Local shear wave speed is recovered using a time-of-flight method based on both LR and RL waves. Finally a 2D shear wave speed map is reconstructed by combining the LR and RL speed maps. Smooth and accurate shear wave speed maps are reconstructed using the proposed CUSE method in two calibrated homogeneous phantoms with different moduli. Inclusion phantom experiments demonstrate that CUSE is capable of providing good contrast (contrast-to-noise-ratio ≥ 25 dB) between the inclusion and background without artifacts and is insensitive to inclusion positions. Safety measurements demonstrate that all regulated parameters of the ultrasound output level used in CUSE sequence are well below the FDA limits for diagnostic ultrasound. PMID:22736690
Effect of Calcifications on Breast Ultrasound Shear Wave Elastography: An Investigational Study
Gregory, Adriana; Mehrmohammadi, Mohammad; Denis, Max; Bayat, Mahdi; Stan, Daniela L.; Fatemi, Mostafa; Alizad, Azra
2015-01-01
Purpose To investigate the effects of macrocalcifications and clustered microcalcifications associated with benign breast masses on shear wave elastography (SWE). Methods SuperSonic Imagine (SSI) and comb-push ultrasound shear elastography (CUSE) were performed on three sets of phantoms to investigate how calcifications of different sizes and distributions influence measured elasticity. To demonstrate the effect in vivo, three female patients with benign breast masses associated with mammographically-identified calcifications were evaluated by CUSE. Results Apparent maximum elasticity (Emax) estimates resulting from individual macrocalcifications (with diameters of 2mm, 3mm, 5mm, 6mm, 9mm, 11mm, and 15mm) showed values over 50 kPa for all cases, which represents more than 100% increase over background (~21kPa). We considered a 2cm-diameter circular region of interest for all phantom experiments. Mean elasticity (Emean) values varied from 26 kPa to 73 kPa, depending on the macrocalcification size. Highly dense clusters of microcalcifications showed higher Emax values than clusters of microcalcification with low concentrations, but the difference in Emean values was not significant. Conclusions Our results demonstrate that the presence of large isolated macrocalcifications and highly concentrated clusters of microcalcifications can introduce areas with apparent high elasticity in SWE. Considering that benign breast masses normally have significantly lower elasticity values than malignant tumors, such areas with high elasticity appearing due to presence of calcification in benign breast masses may lead to misdiagnosis. PMID:26368939
Bifurcation parameters of a reflected shock wave in cylindrical channels of different roughnesses
NASA Astrophysics Data System (ADS)
Penyazkov, O.; Skilandz, A.
2018-03-01
To investigate the effect of bifurcation on the induction time in cylindrical shock tubes used for chemical kinetic experiments, one should know the parameters of the bifurcation structure of a reflected shock wave. The dynamics and parameters of the shock wave bifurcation, which are caused by reflected shock wave-boundary layer interactions, are studied experimentally in argon, in air, and in a hydrogen-nitrogen mixture for Mach numbers M = 1.3-3.5 in a 76-mm-diameter shock tube without any ramp. Measurements were taken at a constant gas density behind the reflected shock wave. Over a wide range of experimental conditions, we studied the axial projection of the oblique shock wave and the pressure distribution in the vicinity of the triple Mach configuration at 50, 150, and 250 mm from the endwall, using side-wall schlieren and pressure measurements. Experiments on a polished shock tube and a shock tube with a surface roughness of 20 {μ }m Ra were carried out. The surface roughness was used for initiating small-scale turbulence in the boundary layer behind the incident shock wave. The effect of small-scale turbulence on the homogenization of the transition zone from the laminar to turbulent boundary layer along the shock tube perimeter was assessed, assuming its influence on a subsequent stabilization of the bifurcation structure size versus incident shock wave Mach number, as well as local flow parameters behind the reflected shock wave. The influence of surface roughness on the bifurcation development and pressure fluctuations near the wall, as well as on the Mach number, at which the bifurcation first develops, was analyzed. It was found that even small additional surface roughness can lead to an overshoot in pressure growth by a factor of two, but it can stabilize the bifurcation structure along the shock tube perimeter.
A comparison of two reciprocating instruments using bending stress and cyclic fatigue tests.
Scelza, Pantaleo; Harry, Davidowicz; Silva, Licinio Esmeraldo da; Barbosa, Igor Bastos; Scelza, Miriam Zaccaro
2015-01-01
The aim of this study was to comparatively evaluate the bending resistance at 45º, the static and dynamic cyclic fatigue life, and the fracture type of the WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) 25-08 and Reciproc (VDW, Munich, Germany) 25-08 instruments. A total of 60 nickel-titanium (NiTi) instruments (30 Reciproc and 30 WaveOne) from three different lots, each of which was 25 mm in length, were tested. The bending resistance was evaluated through the results of a cantilever-bending test conducted using a universal testing machine. Static and dynamic cyclic fatigue testing was conducted using a custom-made device. For the static and dynamic tests, a cast Ni-Cr-Mo-Ti alloy metal block with an artificial canal measuring 1.77 mm in diameter and 20.00 mm in total length was used. A scanning electron microscope was used to determine the type of fracture. Statistical analyses were performed on the results. The WaveOne instrument was less flexible than the Reciproc (p < 0.05). The Reciproc instrument showed better resistance in the static and dynamic cyclic fatigue tests (p < 0.05). The transverse cross-section and geometry of the instruments were important factors in their resistance to bending and cyclic fracture. Both of the instruments showed ductile-type fracture characteristics. It can be concluded that the Reciproc 25-08 instrument was more resistant to static and dynamic cyclic fatigue than the WaveOne 25-08 instrument, while the WaveOne 25-08 instrument was less flexible. Bending and resistance to cyclic fracture were influenced by the instruments' geometries and transverse cross-sections. Both of the instruments showed ductile-type fracture characteristics.
Smith, Terence K; Oliver, Gavin R; Hennig, Grant W; O'Shea, Deirdre M; Vanden Berghe, Pieter; Kang, Sok Han; Spencer, Nick J
2003-09-15
We have investigated the tone dependence of the intrinsic nervous activity generated by localized wall distension in isolated segments of guinea-pig distal colon using mechanical recordings and video imaging of wall movements. A segment of colon was threaded through two partitions, which divided the colon for pharmacological purposes into oral, stimulation and anal regions. An intraluminal balloon was located in the stimulation region between the two partitions (12 mm apart). Maintained colonic distension by an intraluminal balloon or an artificial faecal pellet held at a fixed location generated rhythmic (frequency 0.3 contractions min(-1); duration approximately 60 s) peristaltic waves of contraction. Video imaging of colonic wall movements or the selective application of pharmacological agents suggested that peristaltic waves originated just oral (< or = 4 mm) to the pellet and propagated both orally (approximately 11 mm s(-1)) and anally (approximately 1 mm s(-1)). Also, during a peristaltic wave the colon appears to passively shorten in front of a pellet, as a result of an active contraction of the longitudinal muscle oral to the pellet. Faecal pellet movement only occurred when a rhythmic peristaltic wave was generated. Rhythmic peristaltic waves were abolished in all regions by the smooth muscle relaxants isoproterenol (1 microM), nicardipine (1 microM) or papavarine (10 microM), and by the neural antagonists tetrodotoxin (TTX; 0.6 microM), hexamethonium (100 microM) or atropine (1 microM), when added selectively to the stimulation region. Nicardipine, atropine, TTX, or hexamethonium (100 microM) also blocked the evoked peristaltic waves when selectively added to the oral region. Nomega-nitro-L-arginine (L-NA; 100 microM) added to the anal region reduced the anal relaxation but increased the anal contraction, leading to an increase in the apparent conduction velocity of each peristaltic wave. In conclusion, maintained distension by a fixed artificial pellet generates propulsive, rhythmic peristaltic waves, whose enteric neural activity is critically dependent upon smooth muscle tone. These peristaltic waves usually originate just oral to the pellet, and their apparent conduction velocity is generated by activation of descending inhibitory nerve pathways.
The Object Coordination Class Applied to Wave Pulses: Analyzing Student Reasoning in Wave Physics.
ERIC Educational Resources Information Center
Wittmann, Michael C.
2002-01-01
Analyzes student responses to interview and written questions on wave physics using diSessa and Sherin's coordination class model which suggests that student use of specific reasoning resources is guided by possibly unconscious cues. (Author/MM)
NASA Technical Reports Server (NTRS)
Lu, F. K.; Settles, G. S.; Bogdonoff, S. M.
1983-01-01
The interaction between a turbulent boundary layer and a shock wave generated by a sharp fin with leading edge sweepback was investigated. The incoming flow was at Mach 2.96 and at a unit Reynolds number of 63 x 10 to the 6th power 0.1 m. The approximate incoming boundary layer thickness was either 4 mm or 17 mm. The fins used were at 5 deg, 9 deg and 15 deg incidence and had leading edge sweepback from 0 deg to 65 deg. The tests consisted of surface kerosene lampblack streak visualization, surface pressure measurements, shock wave shape determination by shadowgraphs, and localized vapor screen visualization. The upstream influence lengths of the fin interactions were correlated using viscous and inviscid flow parameters. The parameters affecting the surface features close to the fin and way from the fin were also identified. Essentially, the surface features in the farfield were found to be conical.
Design, fabrication, and testing of an ultrasonic de-icing system for helicopter rotor blades
NASA Astrophysics Data System (ADS)
Palacios, Jose Luis
A low-power, non-thermal ultrasonic de-icing system is introduced as a possible substitute for current electro-thermal systems. The system generates delaminating ultrasonic transverse shear stresses at the interface of accreted ice. A PZT-4 disk driven at 28.5 KHz (radial resonance of the disk) instantaneously de-bonds 2 mm thick freezer ice layers. The ice layers are accreted to a 0.7 mm thick, 30.4 cm x 30.4 cm steel plate at an environment temperature of -20°C. A power input of 50 Watts is applied to the actuator (50 V, 19.6 KV/m), which translates to a de-icing power of 0.07 W/cm2. A finite element model of the actuator bonded to the isotropic plate is used to guide the design of the system, and predicts the transverse shear stresses at the ice interface. Wind tunnel icing tests were conducted to demonstrate the potential use of the proposed system under impact icing conditions. Both glaze ice and rime ice were generated on steel and composite plates by changing the cloud conditions of the wind tunnel. Continuous ultrasonic vibration prevented impact ice formation around the actuator location at an input power not exceeding 0.18 W/cm 2 (1.2 W/in2). As ice thickness reached a critical thickness of approximately 1.2 mm, shedding occurred on those locations where ultrasonic transverse shear stresses exceeded the shear adhesion strength of the ice. Finite element transverse shear stress predictions correlate with observed experimental impact ice de-bonding behavior. To increase the traveling distance of propagating ultrasonic waves, ultrasonic shear horizontal wave modes are studied. Wave modes providing large modal interface transverse shear stress concentration coefficients (ISCC) between the host structure (0.7 mm thick steel plate) and accreted ice (2.5 mm thick ice layer) are identified and investigated for a potential increase in the wave propagation distance. Ultrasonic actuators able to trigger these optimum wave modes are designed and fabricated. Despite exciting wave modes with high ISCC values, instantaneous ice de-bonding is not observed at input powers under 100 Watts. The two triggered ultrasonic wave modes of the structure occur at high excitation frequencies, 202 KHz and 500 KHz respectively. At these frequencies, the ultrasonic actuators do not provide large enough transverse shear stresses to exceed the shear adhesion strength of the ice layer. Neither the actuator exciting the SH1 mode (202 KHz), nor the actuator triggering the SH2 mode (500 KHz) instantaneously de-bonds ice layers with an input power under 100 Watts.
The high temperature impact response of tungsten and chromium
NASA Astrophysics Data System (ADS)
Zaretsky, E. B.; Kanel, G. I.
2017-09-01
The evolution of elastic-plastic shock waves has been studied in pure polycrystalline tungsten and chromium at room and elevated temperatures over propagation distances ranging from 0.05 to 3 mm (tungsten) and from 0.1 to 2 mm (chromium). The use of fused silica windows in all but one experiment with chromium and in several high temperature experiments with tungsten led to the need for performing shock and optic characterization of these windows over the 300-1200 K temperature interval. Experiments with tungsten and chromium samples showed that annealing of the metals transforms the initial ramping elastic wave into a jump-like wave, substantially increasing the Hugoniot elastic limits of the metals. With increased annealing time, the spall strength of the two metals slightly increases. Both at room and at high temperatures, the elastic precursor in the two metals decays in two distinct regimes. At propagation distances smaller than ˜1 mm (tungsten) or ˜0.5 mm (chromium), decay is fast, with the dislocation motion and multiplication being controlled by phonon viscous drag. At greater distances, the rate of decay becomes much lower, with control of the plastic deformation being passed to the thermally activated generation and motion of dislocation double-kinks. The stress at which this transition takes place virtually coincides with the Peierls stress τP of the active glide system. Analysis of the annealing effects in both presently and previously studied BCC metals (i.e., Ta, V, Nb, Mo, W, and Cr) and of the dependencies of their normalized Peierls stresses τP(θ) /τP(0 ) on the normalized temperature θ=T /Tm allows one to conclude that the non-planar, split into several glide planes, structure of the dislocation core in these metals is mainly responsible for their plastic deformation features.
Research on the magnetorheological finishing (MRF) technology with dual polishing heads
NASA Astrophysics Data System (ADS)
Huang, Wen; Zhang, Yunfei; He, Jianguo; Zheng, Yongcheng; Luo, Qing; Hou, Jing; Yuan, Zhigang
2014-08-01
Magnetorheological finishing (MRF) is a key polishing technique capable of rapidly converging to the required surface figure. Due to the deficiency of general one-polishing-head MRF technology, a dual polishing heads MRF technology was studied and a dual polishing heads MRF machine with 8 axes was developed. The machine has the ability to manufacture large aperture optics with high figure accuracy. The large polishing head is suitable for polishing large aperture optics, controlling large spatial length's wave structures, correcting low-medium frequency errors with high removal rates. While the small polishing head has more advantages in manufacturing small aperture optics, controlling small spatial wavelength's wave structures, correcting mid-high frequency and removing nanoscale materials. Material removal characteristic and figure correction ability for each of large and small polishing head was studied. Each of two polishing heads respectively acquired stable and valid polishing removal function and ultra-precision flat sample. After a single polishing iteration using small polishing head, the figure error in 45mm diameter of a 50 mm diameter plano optics was significantly improved from 0.21λ to 0.08λ by PV (RMS 0.053λ to 0.015λ). After three polishing iterations using large polishing head , the figure error in 410mm×410mm of a 430mm×430mm large plano optics was significantly improved from 0.40λ to 0.10λ by PV (RMS 0.068λ to 0.013λ) .This results show that the dual polishing heads MRF machine not only have good material removal stability, but also excellent figure correction capability.
Effects of Stone Size on the Comminution Process and Efficiency in Shock Wave Lithotripsy
Zhang, Ying; Nault, Isaac; Mitran, Sorin; Iversen, Edwin S.; Zhong, Pei
2016-01-01
The effects of stone size on the process and comminution efficiency in shock wave lithotripsy (SWL) are investigated by experiments, numerical simulations, and scale analysis. Cylindrical BegoStone phantoms with approximately equal height and diameter of either 4-, or 7- or 10-mm, in a total aggregated mass of about 1.5 g, were treated in an electromagnetic shock wave lithotripter field. The resultant stone comminution (SC) was found to correlate closely with the average peak pressure, P+(avg), incident on the stones. The P+(avg) threshold to initiate stone fragmentation in water increased from 7.9 to 8.8 to 12.7 MPa, respectively, when the stone size decreased from 10 to 7 to 4 mm. Similar changes in the P+(avg) threshold were observed for the 7- and 10-mm stones treated in 1,3-butanediol where cavitation is suppressed, suggesting that the observed size dependency is due to changes in stress distribution within different size stones. Moreover, the slope of the correlation curve between SC and ln(P‒+(avg)) in water increased with decreasing stone size, while the opposite trend was observed in 1,3-butanediol. The progression of stone comminution in SWL showed a size-dependency with the 7- and 10-mm stones fragmented into progressively smaller pieces while a significant portion (> 30%) of the 4-mm stones were stalemated within the size range of 2.8 ~ 4 mm even after 1,000 shocks. Analytical scaling considerations suggest size-dependent fragmentation behaviour, a hypothesis further supported by numerical model calculations that exhibit changing patterns of constructive and destructive wave interference, and thus variations in the maximum tensile stress or stress integral produced in cylindrical and spherical stone of different sizes. PMID:27515177
Development of 24GHz Rectenna for Receiving and Rectifying Modulated Waves
NASA Astrophysics Data System (ADS)
Shinohara, Naoki; Hatano, Ken
2014-11-01
In this paper, we show experimental results of RF-DC conversion with modulated 24GHz waves. We have already developed class-F MMIC rectenna with resonators for higher harmonics at no modulated 24GHz microwave for RF energy transfer. Dimensions of the MMIC rectifying circuit is 1 mm × 3 mm on GaAs. Maximum RF-DC conversion efficiency is measured 47.9% for a 210 mW microwave input of 24 GHz with a 120 Ω load. The class-F rectenna is based on a single shunt full-wave rectifier. For future application of a simultaneous energy and information transfer system or an energy harvesting from broadcasting waves, input microwave will be modulated. In this paper, we show an experimental result of RF-DC conversion of the class-F rectenna with 24GHz waves modulated by 16QAM as 1st modulation and OFDM as 2nd modulation.
Millimeter wave experiment of ITER equatorial EC launcher mock-up
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takahashi, K.; Oda, Y.; Kajiwara, K.
2014-02-12
The full-scale mock-up of the equatorial launcher was fabricated in basis of the baseline design to investigate the mm-wave propagation properties of the launcher, the manufacturability, the cooling line management, how to assemble the components and so on. The mock-up consists of one of three mm-wave transmission sets and one of eight waveguide lines can deliver the mm-wave power. The mock-up was connected to the ITER compatible transmission line and the 170GHz gyrotron and the high power experiment was carried out. The measured radiation pattern of the beam at the location of 2.5m away from the EL mock-up shows themore » successful steering capability of 20°∼40°. It was also revealed that the radiated profile at both steering and fixed focusing mirror agreed with the calculation. The result also suggests that some unwanted modes are included in the radiated beam. Transmission of 0.5MW-0.4sec and of 0.12MW-50sec were also demonstrated.« less
Filterless frequency-octupling mm-wave generation by cascading Sagnac loop and DPMZM
NASA Astrophysics Data System (ADS)
Zhang, Wu; Wen, Aijun; Gao, Yongsheng; Shang, Shuo; Zheng, Hanxiao; He, Hongye
2017-12-01
In this paper, a filterless photonic frequency-octupling scheme is presented. It is implemented by cascading a Sagnac loop with an intensity modulator (IM) in it and a dual-parallel Mach-Zehnder modulator (DPMZM) in series. The Sagnac loop is used to get the ±2nd-order sidebands of LO signal. The following DPMZM is utilized to obtain the ±4th-order sidebands. By photo-detecting the ±4th-order sidebands, mm-wave signal with the eightfold frequency of LO signal can be obtained. The scheme is verified by experiments, and a 32-GHz mm-wave signal is produced with the assistance of a 4-GHz LO signal. A 20-dB optical sideband suppression ratio (OSSR) and a 17-dB electrical spurious suppression ratio (ESSR) are realized, and no extra deterioration of phase noise is observed. Besides, the verification of the frequency tunability is implemented in the experiment.
NASA Astrophysics Data System (ADS)
Bandurkin, I. V.; Kaminsky, A. K.; Perelstein, E. A.; Peskov, N. Yu.; Savilov, A. V.; Sedykh, S. N.
2012-08-01
The possibility of using frequency multiplication in order to obtain high-power short-wavelength radiation from a free-electron maser (FEM) with a Bragg resonator has been studied. Preliminary experiments with an LIU-3000 (JINR) linear induction accelerator demonstrate the operation of a frequency-multiplying FEM at megawatt power in the 6- and 4-mm wave bands on the second and third harmonic, respectively.
Beck, Darren T; Martin, Jeffrey S; Casey, Darren P; Braith, Randy W
2013-09-01
Large artery stiffness is a major risk factor for the development of hypertension and cardiovascular disease. Persistent prehypertension accelerates the progression of arterial stiffness. Forty-three unmedicated prehypertensive (systolic blood pressure (SBP) = 120-139 mm Hg or diastolic blood pressure (DBP) = 80-89 mm Hg) men and women and 15 normotensive time-matched control subjects (NMTCs; n = 15) aged 18-35 years of age met screening requirements and participated in the study. Prehypertensive subjects were randomly assigned to a resistance exercise training (PHRT; n = 15), endurance exercise training (PHET; n = 13) or time-control group (PHTC; n = 15). Treatment groups performed exercise training 3 days per week for 8 weeks. Pulse wave analysis, pulse wave velocity (PWV), and central and peripheral blood pressures were evaluated before and after exercise intervention or time-matched control. PHRT and PHET reduced resting SBP by 9.6±3.6mm Hg and 11.9±3.4mm Hg, respectively, and DBP by 8.0±5.1mm Hg and 7.2±3.4mm Hg, respectively (P < 0.05). PHRT and PHET decreased augmentation index (AIx) by 7.5% ± 2.8% and 8.1% ± 3.2% (P < 0.05), AIx@75 by 8.0% ± 3.2% and 9.2% ± 3.8% (P < 0.05), and left ventricular wasted pressure energy, an index of extra left ventricular myocardial oxygen requirement due to early systolic wave reflection, by 573±161 dynes s/cm(2) and 612±167 dynes s/cm(2) (P < 0.05), respectively. PHRT and PHET reduced carotid-radial PWV by 1.02±0.32 m/sec and 0.92±0.36 m/sec (P < 0.05) and femoral-distal PWV by 1.04±0.31 m/sec and 1.34±0.33 m/sec (P < 0.05), respectively. No significant changes were observed in the time-control groups. This study suggests that both resistance and endurance exercise alone effectively reduce peripheral arterial stiffness, central blood pressures, augmentation index, and myocardial oxygen demand in young prehypertensive subjects.
2013-01-01
BACKGROUND Large artery stiffness is a major risk factor for the development of hypertension and cardiovascular disease. Persistent prehypertension accelerates the progression of arterial stiffness. METHODS Forty-three unmedicated prehypertensive (systolic blood pressure (SBP) = 120–139mm Hg or diastolic blood pressure (DBP) = 80–89mm Hg) men and women and 15 normotensive time-matched control subjects (NMTCs; n = 15) aged 18–35 years of age met screening requirements and participated in the study. Prehypertensive subjects were randomly assigned to a resistance exercise training (PHRT; n = 15), endurance exercise training (PHET; n = 13) or time-control group (PHTC; n = 15). Treatment groups performed exercise training 3 days per week for 8 weeks. Pulse wave analysis, pulse wave velocity (PWV), and central and peripheral blood pressures were evaluated before and after exercise intervention or time-matched control. RESULTS PHRT and PHET reduced resting SBP by 9.6±3.6mm Hg and 11.9±3.4mm Hg, respectively, and DBP by 8.0±5.1mm Hg and 7.2±3.4mm Hg, respectively (P < 0.05). PHRT and PHET decreased augmentation index (AIx) by 7.5% ± 2.8% and 8.1% ± 3.2% (P < 0.05), AIx@75 by 8.0% ± 3.2% and 9.2% ± 3.8% (P < 0.05), and left ventricular wasted pressure energy, an index of extra left ventricular myocardial oxygen requirement due to early systolic wave reflection, by 573±161 dynes s/cm2 and 612±167 dynes s/cm2 (P < 0.05), respectively. PHRT and PHET reduced carotid–radial PWV by 1.02±0.32 m/sec and 0.92±0.36 m/sec (P < 0.05) and femoral–distal PWV by 1.04±0.31 m/sec and 1.34±0.33 m/sec (P < 0.05), respectively. No significant changes were observed in the time-control groups. CONCLUSIONS This study suggests that both resistance and endurance exercise alone effectively reduce peripheral arterial stiffness, central blood pressures, augmentation index, and myocardial oxygen demand in young prehypertensive subjects. PMID:23736111
A clinical nomogram to predict the successful shock wave lithotripsy of renal and ureteral calculi.
Wiesenthal, Joshua D; Ghiculete, Daniela; Ray, A Andrew; Honey, R John D'A; Pace, Kenneth T
2011-08-01
Although shock wave lithotripsy is dependent on patient and stone related factors, there are few reliable algorithms predictive of its success. In this study we develop a comprehensive nomogram to predict renal and ureteral stone shock wave lithotripsy outcomes. During a 5-year period data from patients treated at our lithotripsy unit were reviewed. Analysis was restricted to patients with a solitary renal or ureteral calculus 20 mm or less. Demographic, stone, patient, treatment and 3-month followup data were collected from a prospective database. All patients were treated using the Philips Lithotron® lithotripter. A total of 422 patients (69.7% male) were analyzed. Mean stone size was 52.3±39.3 mm2 for ureteral stones and 78.9±77.3 mm2 for renal stones, with 95 (43.6%) of the renal stones located in the lower pole. The single treatment success rates for ureteral and renal stones were 60.3% and 70.2%, respectively. On univariate analysis predictors of shock wave lithotripsy success, regardless of stone location, were age (p=0.01), body mass index (p=0.01), stone size (p<0.01), mean stone density (p<0.01) and skin to stone distance (p<0.01). By multivariate logistic regression for renal calculi, age, stone area and skin to stone distance were significant predictors with an AUC of 0.75. For ureteral calculi predictive factors included body mass index and stone size (AUC 0.70). Patient and stone parameters have been identified to create a nomogram that predicts shock wave lithotripsy outcomes using the Lithotron lithotripter, which can facilitate optimal treatment based decisions and provide patients with more accurate single treatment success rates for shock wave lithotripsy tailored to patient specific situations. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
A novel traveling wave piezoelectric actuated tracked mobile robot utilizing friction effect
NASA Astrophysics Data System (ADS)
Wang, Liang; Shu, Chengyou; Jin, Jiamei; Zhang, Jianhui
2017-03-01
A novel traveling wave piezoelectric-actuated tracked mobile robot with potential application to robotic rovers was proposed and investigated in this study. The proposed tracked mobile robot is composed of a parallelogram-frame-structure piezoelectric transducer with four rings and a metal track. Utilizing the converse piezoelectric and friction effects, traveling waves were propagated in the rings and then the metal track was actuated by the piezoelectric transducer. Compared with traditional tracked mechanisms, the proposed tracked mobile robot has a simpler and more compact structure without lubricant, which eliminates the problem of lubricant volatilization and deflation, thus, it could be operated in the vacuum environment. Dynamic characteristics were simulated and measured to reveal the mechanism of actuating track of the piezoelectric transducer. Experimental investigations of the traveling wave piezoelectric-actuated tracked mobile robot were then carried out, and the results indicated that the robot prototype with a pair of exciting voltages of 460 Vpp is able to achieve a maximum velocity of 57 mm s-1 moving on the foam plate and possesses the obstacle crossing capability with a maximum height of 27 mm. The proposed tracked mobile robot exhibits potential to be the driving system of robotic rovers.
Banerjee, Bhadrani; Tripathi, Anvita; Das, Adrija; Singh, Kumari Alka; Banerjee, J. P.
2015-01-01
The authors have carried out the large-signal (L-S) simulation of double-drift region (DDR) impact avalanche transit time (IMPATT) diodes based on 〈111〉, 〈100〉, and 〈110〉 oriented GaAs. A nonsinusoidal voltage excited (NSVE) L-S simulation technique is used to investigate both the static and L-S performance of the above-mentioned devices designed to operate at millimeter-wave (mm-wave) atmospheric window frequencies, such as 35, 94, 140, and 220 GHz. Results show that 〈111〉 oriented GaAs diodes are capable of delivering maximum RF power with highest DC to RF conversion efficiency up to 94 GHz; however, the L-S performance of 〈110〉 oriented GaAs diodes exceeds their other counterparts while the frequency of operation increases above 94 GHz. The results presented in this paper will be helpful for the future experimentalists to choose the GaAs substrate of appropriate orientation to fabricate DDR GaAs IMPATT diodes at mm-wave frequencies. PMID:27347524
Sound pressure distribution within natural and artificial human ear canals: forward stimulation.
Ravicz, Michael E; Tao Cheng, Jeffrey; Rosowski, John J
2014-12-01
This work is part of a study of the interaction of sound pressure in the ear canal (EC) with tympanic membrane (TM) surface displacement. Sound pressures were measured with 0.5-2 mm spacing at three locations within the shortened natural EC or an artificial EC in human temporal bones: near the TM surface, within the tympanic ring plane, and in a plane transverse to the long axis of the EC. Sound pressure was also measured at 2-mm intervals along the long EC axis. The sound field is described well by the size and direction of planar sound pressure gradients, the location and orientation of standing-wave nodal lines, and the location of longitudinal standing waves along the EC axis. Standing-wave nodal lines perpendicular to the long EC axis are present on the TM surface >11-16 kHz in the natural or artificial EC. The range of sound pressures was larger in the tympanic ring plane than at the TM surface or in the transverse EC plane. Longitudinal standing-wave patterns were stretched. The tympanic-ring sound field is a useful approximation of the TM sound field, and the artificial EC approximates the natural EC.
Statistical Analysis of Acoustic Wave Power and Flows around Solar Active Regions
NASA Astrophysics Data System (ADS)
Rabello-Soares, M. Cristina; Bogart, Richard S.; Scherrer, Philip H.
2018-05-01
We analyze the effect of a sunspot in its quiet surroundings applying a helioseismic technique on almost three years of Helioseismic and Magnetic Imager (HMI) observations obtained during solar cycle 24 to further study the sunspot structure below the solar surface. The attenuation of acoustic waves with frequencies lower than 4.2 mHz depends more strongly on the wave direction at a distance of 6°–7° from the sunspot center. The amplification of higher frequency waves is highest 6° away from the active region and is largely independent of the wave’s direction. We observe a mean clockwise flow around active regions, the angular speed of which decreases exponentially with distance and has a coefficient close to ‑0.7 degree‑1. The observed horizontal flow in the direction of the nearby active region agrees with a large-scale circulation around the sunspot in the shape of cylindrical shell. The center of the shell seems to be centered around 7° from the sunspot center, where we observe an inflow close to the surface down to ∼2 Mm, followed by an outflow at deeper layers until at least 7 Mm.
NASA Technical Reports Server (NTRS)
Steffes, Paul G.
1991-01-01
Laboratory measurements of microwave and millimeter wave properties of the simulated atmosphere of the outer planets and their satellites has continued. One of the focuses is on the development of a radiative transfer model of the Jovian atmosphere at wavelengths from 1 mm to 10 cm. This modeling effort led to laboratory measurements of the millimeter wave opacity of hydrogen sulfide (H2S) under simulated Jovian conditions. Descriptions of the modeling effort, the Laboratory experiment, and the observations are presented. Correlative studies of measurements with Pioneer-Venus radio occultation measurements with longer wavelength emission measurements have provided new ways for characterizing temporal and spatial variations in the abundance of both gases H2SO4 and SO2, and for modeling their roles in the subcloud atmosphere. Laboratory measurements were conducted on 1.35 cm (and 13 cm) opacity of gaseous SO2 and absorptivity of gaseous SO2 at the 3.2 mm wavelength under simulated Venus conditions. Laboratory measurements were completed on millimeter wave dielectric properties of liquid H2SO4, in order to model the effects of the opacity of the clouds of Venus onto millimeter wave emission spectrum.
Pulse Wave Velocity Predicts Response to Renal Denervation in Isolated Systolic Hypertension.
Fengler, Karl; Rommel, Karl-Philipp; Hoellriegel, Robert; Blazek, Stephan; Besler, Christian; Desch, Steffen; Schuler, Gerhard; Linke, Axel; Lurz, Philipp
2017-05-17
Renal sympathetic denervation seems to be less effective as a treatment for hypertension in patients with isolated systolic hypertension, a condition associated with elevated central arterial stiffness. Because isolated systolic hypertension can also be caused by wave reflection or increased cardiac output, a more differentiated approach might improve patient preselection for renal sympathetic denervation. We sought to evaluate the additional predictive value of invasive pulse wave velocity for response to renal sympathetic denervation in patients with combined versus isolated systolic hypertension. Patients scheduled for renal sympathetic denervation underwent additional invasive measurement of pulse wave velocity and pulse pressure before denervation. Blood pressure was assessed via ambulatory measurement at baseline and after 3 months. In total 109 patients (40 patients with isolated systolic hypertension) were included in our analysis. After 3 months, blood pressure reduction was more pronounced among patients with combined hypertension compared with patients with isolated systolic hypertension (systolic 24-hour average 9.3±10.5 versus 5.0±11.5 mm Hg, P =0.046). However, when stratifying patients with isolated systolic hypertension by invasive pulse wave velocity, patients in the lowest tertile of pulse wave velocity had comparable blood pressure reduction (12.1±12.6 mm Hg, P =0.006) despite lower baseline blood pressure than patients with combined hypertension (systolic 24-hour average 154.8±12.5 mm Hg in combined hypertension versus 141.2±8.1, 148.4±10.9, and 150.5±12.7 mm Hg, respectively, by tertiles of pulse wave velocity, P =0.002). Extended assessment of arterial stiffness can help improve patient preselection for renal sympathetic denervation and identify a subgroup of isolated systolic hypertension patients who benefit from sympathetic modulation. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Kowalski, Remi R; Beare, Richard; Mynard, Jonathan P; Cheong, Jeanie L Y; Doyle, Lex W; Smolich, Joseph J; Cheung, Michael M H
2018-03-29
To evaluate the wave reflection characteristics in the aortic arch and common carotid artery of ex-preterm adolescents and assess their relationship to central blood pressure in a cohort followed prospectively since birth. Central blood pressures, pulse wave velocity, augmentation index, microvascular reactive hyperemia, arterial distensibility, compliance and stiffness index, and also aortic and carotid wave intensity were measured in 18-year-olds born extremely preterm at below 28 weeks' gestation (n = 76) and term-born controls (n = 42). Compared with controls, ex-preterm adolescents had higher central systolic (111 ± 11 vs. 105 ± 10 mmHg; P < 0.001) and diastolic blood pressures (73 ± 7 vs. 67 ± 7 mmHg; P < 0.001). Although conventional measures of arterial function and biomechanics such as pulse wave velocity and augmentation index were no different between groups, wave intensity analysis revealed elevated backward compression wave area (-0.39 ± 0.21 vs. -0.29 ± 0.17 W/m/s × 10; P = 0.03), backward compression wave pressure change (9.0 ± 3.5 vs. 6.6 ± 2.5 mmHg; P = 0.001) and reflection index (0.44 ± 0.15 vs. 0.32 ± 0.08; P < 0.001) in the aorta of ex-preterm adolescents compared with controls. These changes were less pronounced in the carotid artery. On multivariable analysis, forward and backward compression wave areas were the only biomechanical variables associated with central systolic pressure. Ex-preterm adolescents demonstrate elevated wave reflection indices in the aortic arch, which correlate with central systolic pressure. Wave intensity analysis may provide a sensitive novel marker of evolving vascular dysfunction in ex-preterm survivors.
Propagation of detonation wave in hydrogen-air mixture in channels with sound-absorbing surfaces
NASA Astrophysics Data System (ADS)
Bivol, G. Yu.; Golovastov, S. V.; Golub, V. V.
2015-12-01
The possibility of using sound-absorbing surfaces for attenuating the intensity of detonation waves propagating in hydrogen-air mixtures has been experimentally studied in a cylindrical detonation tube open at one end, with an explosive initiated by spark discharge at the closed end. Sound-absorbing elements were made of an acoustic-grade foamed rubber with density of 0.035 g/cm3 containing open pores with an average diameter of 0.5 mm. The degree of attenuation of the detonation wave front velocity was determined as dependent on the volume fraction of hydrogen in the gas mixture.
NASA Technical Reports Server (NTRS)
Simons, Rainee N.; Wintucky, Edwin G.
2017-01-01
This paper presents the design, fabrication, and test results for a novel waveguide multimode directional coupler (MDC). The coupler fabricated from dissimilar frequency band waveguides, is capable of isolating power at the 2nd harmonic frequency from the fundamental power at the output port of traveling-wave tube amplifiers. Test results from proof-of-concept demonstrations are presented for Ku/Ka-band and Ka/E-band MDCs, which demonstrate sufficient power in the 2nd harmonic for a space borne beacon source for mm-wave atmospheric propagation studies.
Wang, Y H; Grenabo, L; Hedelin, H; Pettersson, S; Wikholm, G; Zachrisson, B F
1993-04-01
A total of 100 whole stones was fragmented in vitro at 3-minute intervals with piezoelectric shock waves using the EDAP LT-01 device until all fragments were less than 2 mm. Larger stones and stones with a high computerized tomography attenuation needed longer treatments for fragmentation. Smoothly bulging stones with an even structure according to plain x-ray films were also more resistant to the shock wave treatment. Calcium oxalate monohydrate stones were not more difficult to break than other types of calculi. Stone fragments from 100 patients after extracorporeal shock wave lithotripsy were also analyzed. The average size of the fragments collected was less than 1 mm. Larger stones produced larger fragments and required more treatment sessions.
Fang, Yuan; Yu, Jianjun; Chi, Nan; Xiao, Jiangnan
2014-01-27
We experimentally demonstrated full-duplex bidirectional transmission of 10-Gb/s millimeter-wave (mm-wave) quadrature phase shift keying (QPSK) signal in E-band (71-76 GHz and 81-86 GHz) optical wireless link. Single-mode fibers (SMF) are connected at both sides of the antenna for uplink and downlink which realize 40-km SMF and 2-m wireless link for bidirectional transmission simultaneously. We utilized multi-level modulation format and coherent detection in such E-band optical wireless link for the first time. Mm-wave QPSK signal is generated by photonic technique to increase spectrum efficiency and received signal is coherently detected to improve receiver sensitivity. After the coherent detection, digital signal processing is utilized to compensate impairments of devices and transmission link.
VizieR Online Data Catalog: 2mm molecular line survey of IRC+10 216 (Cernicharo+, 2000)
NASA Astrophysics Data System (ADS)
Cernicharo, J.; Guelin, M.; Kahane, C.
2000-01-01
The mm-wave spectrum of the C-star envelope IRC+10 216 has been continuously surveyed between 129.0 and 172.5GHz with the IRAM 30-m telescope. 380 lines are detected, of which 317 have been identified. The identified lines arise from 30 different molecules and radicals which, in their vast majority, are not observed in hot and dense interstellar clouds such as Orion A or W3(OH). Actually, half of the molecular species identified in the mm-wave spectrum of IRC+10216 were first observed in the course of this spectral survey. (9 data files).
Ultrasound elastic tensor imaging: comparison with MR diffusion tensor imaging in the myocardium
NASA Astrophysics Data System (ADS)
Lee, Wei-Ning; Larrat, Benoît; Pernot, Mathieu; Tanter, Mickaël
2012-08-01
We have previously proven the feasibility of ultrasound-based shear wave imaging (SWI) to non-invasively characterize myocardial fiber orientation in both in vitro porcine and in vivo ovine hearts. The SWI-estimated results were in good correlation with histology. In this study, we proposed a new and robust fiber angle estimation method through a tensor-based approach for SWI, coined together as elastic tensor imaging (ETI), and compared it with magnetic resonance diffusion tensor imaging (DTI), a current gold standard and extensively reported non-invasive imaging technique for mapping fiber architecture. Fresh porcine (n = 5) and ovine (n = 5) myocardial samples (20 × 20 × 30 mm3) were studied. ETI was firstly performed to generate shear waves and to acquire the wave events at ultrafast frame rate (8000 fps). A 2.8 MHz phased array probe (pitch = 0.28 mm), connected to a prototype ultrasound scanner, was mounted on a customized MRI-compatible rotation device, which allowed both the rotation of the probe from -90° to 90° at 5° increments and co-registration between two imaging modalities. Transmural shear wave speed at all propagation directions realized was firstly estimated. The fiber angles were determined from the shear wave speed map using the least-squares method and eigen decomposition. The test myocardial sample together with the rotation device was then placed inside a 7T MRI scanner. Diffusion was encoded in six directions. A total of 270 diffusion-weighted images (b = 1000 s mm-2, FOV = 30 mm, matrix size = 60 × 64, TR = 6 s, TE = 19 ms, 24 averages) and 45 B0 images were acquired in 14 h 30 min. The fiber structure was analyzed by the fiber-tracking module in software, MedINRIA. The fiber orientation in the overlapped myocardial region which both ETI and DTI accessed was therefore compared, thanks to the co-registered imaging system. Results from all ten samples showed good correlation (r2 = 0.81, p < 0.0001) and good agreement (3.05° bias) between ETI and DTI fiber angle estimates. The average ETI-estimated fractional anisotropy (FA) values decreased from subendocardium to subepicardium (p < 0.05, unpaired, one-tailed t-test, N = 10) by 33%, whereas the corresponding DTI-estimated FA values presented a change of -10% (p > 0.05, unpaired, one-tailed t-test, N = 10). In conclusion, we have demonstrated that the fiber orientation estimated by ETI, which assesses the shear wave speed (and thus the stiffness), was comparable to that measured by DTI, which evaluates the preferred direction of water diffusion, and have validated this concept within the myocardium. Moreover, ETI was shown capable of mapping the transmural fiber angles with as few as seven shear wave propagation directions.
Microfabricated Millimeter-Wave High-Power Vacuum Electronic Amplifiers
2015-01-01
Applications filed 2012). In spite of the challenges, high power sources of electromagnetic radiation are needed in the mmW bands for advanced DoD...Research Laboratory is demonstrating and developing millimeter-wave vacuum electronic traveling wave tube amplifiers at W- and G- band in the 10’ s to 100... s of watts power range at several percent instantaneous bandwidth. Keywords: Traveling wave tube; millimeter wave; vacuum electron device
Fan, Rong; He, Tao; Qiu, Yan; Di, Yu-Lan; Xu, Su-yun; Li, Yao-yu
2012-01-01
To evaluate the differences of wavefront aberrations under cycloplegic, scotopic and photopic conditions. A total of 174 eyes of 105 patients were measured using the wavefront sensor (WaveScan® 3.62) under different pupil conditions: cycloplegic 8.58 ± 0.54 mm (6.4 mm - 9.5 mm), scotopic 7.53 ± 0.69 mm (5.7 mm - 9.1 mm) and photopic 6.08 ± 1.14 mm (4.1 mm - 8.8 mm). The pupil diameter, standard Zernike coefficients, root mean square of higher-order aberrations and dominant aberrations were compared between cycloplegic and scotopic conditions, and between scotopic and photopic conditions. The pupil diameter was 7.53 ± 0.69 mm under the scotopic condition, which reached the requirement of about 6.5 mm optical zone design in the wavefront-guided surgery and prevented measurement error due to the pupil centroid shift caused by mydriatics. Pharmacological pupil dilation induced increase of standard Zernike coefficients Z(3)(-3), Z(4)(0) and Z(5)(-5). The higher-order aberrations, third-order aberration, fourth-order aberration, fifth-order aberration, sixth-order aberration, and spherical aberration increased statistically significantly, compared to the scotopic condition (P<0.010). When the scotopic condition shifted to the photopic condition, the standard Zernike coefficients Z(4)(0), Z(4)(2), Z(6)(-4), Z(6)(-2), Z(6)(2) decreased and all the higher-order aberrations decreased statistically significantly (P<0.010), demonstrating that accommodative miosis can significantly improve vision under the photopic condition. Under the three conditions, the vertical coma aberration appears the most frequently within the dominant aberrations without significant effect by pupil size variance, and the proportion of spherical aberrations decreased with the decrease of the pupil size. The wavefront aberrations are significantly different under cycloplegic, scotopic and photopic conditions. Using the wavefront sensor (VISX WaveScan) to measure scotopic wavefront aberrations is feasible for the wavefront-guided refractive surgery.
Zhu, Zihang; Zhao, Shanghong; Zheng, Wanze; Wang, Wei; Lin, Baoqin
2015-11-10
A novel frequency 12-tupling optical millimeter-wave (mm-wave) generation using two cascaded dual-parallel Mach-Zehnder modulators (DP-MZMs) without an optical filter is proposed and demonstrated by computer simulation. By properly adjusting the amplitude and phase of radio frequency (RF) driving signal and the direct current (DC) bias points of two DP-MZMs, a 120 GHz mm-wave with an optical sideband suppression ratio (OSSR) of 25.1 dB and a radio frequency spurious suppression ratio (RFSSR) of 19.1 dB is shown to be generated from a 10 GHz RF driving signal, which largely reduces the response frequency of electronic devices. Furthermore, it is also proved to be valid that even if the phase difference of RF driving signals, the RF driving voltage, and the DC bias voltage deviate from the ideal values to a certain degree, the performance is still acceptable. Since no optical filter is employed to suppress the undesired optical sidebands, a high-spectral-purity mm-wave signal tunable from 48 to 216 GHz can be obtained theoretically when a RF driving signal from 4 to 18 GHz is applied to the DP-MZMs, and the system can be readily implemented in wavelength-division-multiplexing upconversion systems to provide high-quality optical local oscillator signal.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, G. Barratt, E-mail: barratt@mit.edu, E-mail: barratt.park@gmail.com; Womack, Caroline C.; Jiang, Jun
2015-04-14
Millimeter-wave detected, millimeter-wave optical double resonance (mmODR) spectroscopy is a powerful tool for the analysis of dense, complicated regions in the optical spectra of small molecules. The availability of cavity-free microwave and millimeter wave spectrometers with frequency-agile generation and detection of radiation (required for chirped-pulse Fourier-transform spectroscopy) opens up new schemes for double resonance experiments. We demonstrate a multiplexed population labeling scheme for rapid acquisition of double resonance spectra, probing multiple rotational transitions simultaneously. We also demonstrate a millimeter-wave implementation of the coherence-converted population transfer scheme for background-free mmODR, which provides a ∼10-fold sensitivity improvement over the population labeling scheme.more » We analyze perturbations in the C{sup ~} state of SO{sub 2}, and we rotationally assign a b{sub 2} vibrational level at 45 328 cm{sup −1} that borrows intensity via a c-axis Coriolis interaction. We also demonstrate the effectiveness of our multiplexed mmODR scheme for rapid acquisition and assignment of three predissociated vibrational levels of the C{sup ~} state of SO{sub 2} between 46 800 and 47 650 cm{sup −1}.« less
Martini, Lucia; Giavaresi, Gianluca; Fini, Milena; Borsari, Veronica; Torricelli, Paola; Giardino, Roberto
2006-11-01
Extracorporeal shockwave therapy (ESWT) has been increasingly applied to treat orthopedic and musculoskeletal pathologies. ESWT involves mechanical perturbations that, as with other physical therapies, can result in mechanical stimuli to a large number of cells, including bone cells. The aim of this study was to evaluate the effects of shock waves on osteoblast-like cells (MG63) when using two different generators of shock waves (electrohydraulic and electromagnetic devices), in terms of cell damage, cell viability, osteogenic phenotype expression, and cytokine production. MG63 cells were suspended in 1.5 mL screw-cap cryotubes (1 x 10 cells/mL), containing phosphate buffer solution (PBS), which were maintained at 37 degrees C during all the experimental times. Two levels of energy flux density (EFD) were evaluated for each device: 0.15 to 0.18 mJ/mm2 and 0.40 mJ/mm2. Cells were then cultivated for 72 hours starting from a concentration of 1 x 10 cells/mL, and biological activity and viability were evaluated 24 and 72 hours after treatment. The results obtained demonstrate that the factors most affecting osteoblast activity involve both the device and the level of EFD selected, and they must be considered all together. The use of the electromagnetic device and a level of EFD lower than 0.40 mJ/mm2 would appear to induce fewer immediate cytodestructive effects and better stimulate subsequent proliferation and the synthetic activity of MG63.
Dynamic cycling in atrial size and flow during obstructive apnoea.
Pressman, Gregg S; Cepeda-Valery, Beatriz; Codolosa, Nicolas; Orban, Marek; Samuel, Solomon P; Somers, Virend K
2016-01-01
Obstructive sleep apnoea (OSA) is strongly associated with cardiovascular disease. However, acute cardiovascular effects of repetitive airway obstruction are poorly understood. While past research used a sustained Mueller manoeuver to simulate OSA we employed a series of gasping efforts to better simulate true obstructive apnoeas. This report describes acute changes in cardiac anatomy and flow related to sudden changes in intrathoracic pressure. 26 healthy, normal weight participants performed 5-6 gasping efforts (target intrathoracic pressure -40 mm Hg) while undergoing Doppler echocardiography. 14 participants had sufficient echocardiographic images to allow comparison of atrial areas during the manoeuver with baseline measurements. Mitral and tricuspid E-wave and A-wave velocities postmanoeuver were compared with baseline in all participants. Average atrial areas changed little during the manoeuver, but variance in both atrial areas was significantly greater than baseline. Further, an inverse relationship was noted with left atrial collapse and right atrial enlargement at onset of inspiratory effort. Significant inverse changes were noted in Doppler flow when comparing the first beat postmanoeuver (pMM1) with baseline. Mitral E-wave velocity increased 9.1 cm/s while tricuspid E-wave velocity decreased 7.0 cm/s; by the eighth beat postmanoeuver (pMM8) values were not different from baseline. Mitral and tricuspid A-wave velocities were not different from baseline at pMM1, but both were significantly higher by pMM8. Repetitive obstructive apnoeas produce dynamic, inverse changes in atrial size and Doppler flow across the atrioventricular valves. These observations have important implications for understanding the pathophysiology of OSA.
The impact of intraocular pressure on elastic wave velocity estimates in the crystalline lens.
Park, Suhyun; Yoon, Heechul; Larin, Kirill V; Emelianov, Stanislav Y; Aglyamov, Salavat R
2016-12-20
Intraocular pressure (IOP) is believed to influence the mechanical properties of ocular tissues including cornea and sclera. The elastic properties of the crystalline lens have been mainly investigated with regard to presbyopia, the age-related loss of accommodation power of the eye. However, the relationship between the elastic properties of the lens and IOP remains to be established. The objective of this study is to measure the elastic wave velocity, which represents the mechanical properties of tissue, in the crystalline lens ex vivo in response to changes in IOP. The elastic wave velocities in the cornea and lens from seven enucleated bovine globe samples were estimated using ultrasound shear wave elasticity imaging. To generate and then image the elastic wave propagation, an ultrasound imaging system was used to transmit a 600 µs pushing pulse at 4.5 MHz center frequency and to acquire ultrasound tracking frames at 6 kHz frame rate. The pushing beams were separately applied to the cornea and lens. IOP in the eyeballs was varied from 5 to 50 mmHg. The results indicate that while the elastic wave velocity in the cornea increased from 0.96 ± 0.30 m s -1 to 6.27 ± 0.75 m s -1 as IOP was elevated from 5 to 50 mmHg, there were insignificant changes in the elastic wave velocity in the crystalline lens with the minimum and the maximum speeds of 1.44 ± 0.27 m s -1 and 2.03 ± 0.46 m s -1 , respectively. This study shows that ultrasound shear wave elasticity imaging can be used to assess the biomechanical properties of the crystalline lens noninvasively. Also, it was observed that the dependency of the crystalline lens stiffness on the IOP was significantly lower in comparison with that of cornea.
A Stability Analysis for a Hydrodynamic Three-Wave Journal Bearing
NASA Technical Reports Server (NTRS)
Ene, Nicoleta M.; Dimofte, Florin; Keith, Theo G., Jr.
2007-01-01
The influence of the wave amplitude and oil supply pressure on the dynamic behavior of a hydrodynamic three-wave journal bearing is presented. Both, a transient and a small perturbation technique, were used to predict the threshold to fractional frequency whirl (FFW). In addition, the behavior of the rotor after FFW appeared was determined from the transient analysis. The turbulent effects were also included in the computations. Bearings having a diameter of 30 mm, a length of 27.5 mm, and a clearance of 35 microns were analyzed. Numerical results were compared to experimental results obtained at the NASA GRC. Numerical and experimental results showed that the above-mentioned wave bearing with a wave amplitude ratio of 0.305 operates stably at rotational speeds up to 60,000 rpm, regardless of the oil supply pressure. For smaller wave amplitude ratios, a threshold of stability was found. It was observed that the threshold of stability for lower wave amplitude strongly depends on the oil supply pressure and on the wave amplitude. When the FFW occurs, the journal center maintains its trajectory inside the bearing clearance and therefore the rotor can be run safely without damaging the bearing surfaces.
Feltovich, Helen; Homyk, Andrew D.; Carlson, Lindsey C.; Hall, Timothy J.
2015-01-01
The uterine cervix softens, shortens, and dilates throughout pregnancy in response to progressive disorganization of its layered collagen microstructure. This process is an essential part of normal pregnancy, but premature changes are associated with preterm birth. Clinically, there are no reliable noninvasive methods to objectively measure cervical softening or assess cervical microstructure. The goal of these preliminary studies was to evaluate the feasibility of using an intracavity ultrasound array to generate acoustic radiation force impulse (ARFI) excitations in the uterine cervix through simulation, and to optimize the acoustic radiation force (ARF) excitation for shear wave elasticity imaging (SWEI) of the tissue stiffness. The cervix is a unique soft tissue target for SWEI because it has significantly greater acoustic attenuation (α = 1.3 to 2.0 dB·cm−1·MHz−1) than other soft tissues, and the pathology being studied tends to lead to an increase in tissue compliance, with healthy cervix being relatively stiff compared with other soft tissues (E ≈ 25 kPa). Additionally, the cervix can only be accessed in vivo using a transvaginal or catheter-based array, which places additional constraints on the excitation focal characteristics that can be used during SWEI. Finite element method (FEM) models of SWEI show that larger-aperture, catheter-based arrays can utilize excitation frequencies up to 7 MHz to generate adequate focal gain up to focal depths 10 to 15 mm deep, with higher frequencies suffering from excessive amounts of near-field acoustic attenuation. Using full-aperture excitations can yield ~40% increases in ARFI-induced displacements, but also restricts the depth of field of the excitation to ~0.5 mm, compared with 2 to 6 mm, which limits the range that can be used for shear wave characterization of the tissue. The center-frequency content of the shear wave particle velocity profiles ranges from 1.5 to 2.5 kHz, depending on the focal configuration and the stiffness of the material being imaged. Overall, SWEI is possible using catheter-based imaging arrays to generate adequate displacements in cervical tissue for shear wave imaging, although specific considerations must be made when optimizing these arrays for this shear wave imaging application. PMID:24081254
Effects of exposure to violence with a weapon during adolescence on adult hypertension.
Ford, Jodi L; Browning, Christopher R
2014-03-01
To examine the longitudinal associations between exposure to violence with a weapon during the past year among adolescents and hypertension during adulthood, including the extent to which adult cardiovascular risk factors mediated the association. Secondary analysis of the National Longitudinal Study of Adolescent Health, 1994-2008. The sample included 3555 male and 4416 female participants who were aged 11-17 years at wave 1 (1994-1995). Participants were categorized as hypertensive if they had a mean systolic blood pressure of 140 mm Hg or higher or a mean diastolic pressure of 90 mm Hg or higher at wave 4 (2008). Witnessed violence with a weapon was defined as having seen a shooting or stabbing during the year before wave 1, whereas victim of violence with a weapon was defined as having been shot, cut, or stabbed or had a gun or knife drawn on them during the year before wave 1. Potential mediators of adult cardiovascular risk (wave 4) included body mass index, daily smoking, alcohol abuse, and depression. Males who witnessed violence and females who were victims of violence in the year before wave 1 had an increased odds of hypertension at wave 4 compared with their unexposed peers (adjusted odds ratio, 1.45; 95% confidence interval, 1.003-2.10 and adjusted odds ratio, 1.72; 95% confidence interval, 1.04-2.84, respectively). The hypothesized adult cardiovascular risk mediators did not significantly attenuate the associations for either the male or female samples. Interventions addressing prior violence exposure are needed to promote adult cardiovascular health. Copyright © 2014 Elsevier Inc. All rights reserved.
Holt, L A; Alexander, M J; Coy, L; Liu, C; Molod, A; Putman, W; Pawson, S
2017-07-01
In this study, gravity waves (GWs) in the high-resolution GEOS-5 Nature Run are first evaluated with respect to satellite and other model results. Southern Hemisphere winter sources of non-orographic GWs in the model are then investigated by linking measures of tropospheric non-orographic gravity wave generation tied to precipitation and frontogenesis with absolute gravity wave momentum flux in the lower stratosphere. Finally, non-orographic GW momentum flux is compared to orographic gravity wave momentum flux and compared to previous estimates. The results show that the global patterns in GW amplitude, horizontal wavelength, and propagation direction are realistic compared to observations. However, as in other global models, the amplitudes are weaker and horizontal wavelengths longer than observed. The global patterns in absolute GW momentum flux also agree well with previous model and observational estimates. The evaluation of model non-orographic GW sources in the Southern Hemisphere winter shows that strong intermittent precipitation (greater than 10 mm h -1 ) is associated with GW momentum flux over the South Pacific, whereas frontogenesis and less intermittent, lower precipitation rates (less than 10 mm h -1 ) are associated with GW momentum flux near 60°S. In the model, orographic GWs contribute almost exclusively to a peak in zonal mean momentum flux between 70 and 75°S, while non-orographic waves dominate at 60°S, and non-orographic GWs contribute a third to a peak in zonal mean momentum flux between 25 and 30°S.
A Cascaded Self-Similar Rat-Race Hybrid Coupler Architecture and its Compact Ka-Band Implementation
2017-03-01
real-estate and limit the system-level performance, including bandwidth, gain, and energy - efficiency. These many challenges are positioning passive...and are used in numerous RF/mm-wave systems for radar and wireless communications. Although a Marchand balun covers a large bandwidth, it is...requires multiple λ/4 transmission lines (t-lines), making its on-chip designs very costly even for RF/mm-wave bands. Reported miniaturized rat-race
1993-03-01
I1. NON COHERENT-REFLECTOMETRY The design of sources of steady-state intencive noise signals of mm wave band with sufficiently wide and homogenious...structures exhibit non -reciprocity effects, as well as magnetically controlled resonances, which are observable in reflection, absorption, and...performance of the oscillator. Accordingly, we designed a 3mm electronically tuned harmonic -420- oscillator in which it is easy to debug and control
Optimized Plane Wave Imaging for Fast and High-Quality Ultrasound Imaging.
Jensen, Jonas; Stuart, Matthias Bo; Jensen, Jorgen Arendt
2016-11-01
This paper presents a method for optimizing parameters affecting the image quality in plane wave imaging. More specifically, the number of emissions and steering angles is optimized to attain the best images with the highest frame rate possible. The method is applied to a specific problem, where image quality for a λ -pitch transducer is compared with a λ /2-pitch transducer. Grating lobe artifacts for λ -pitch transducers degrade the contrast in plane wave images, and the impact on frame rate is studied. Field II simulations of plane wave images are made for all combinations of the parameters, and the optimal setup is selected based on Pareto optimality. The optimal setup for a simulated 4.1-MHz λ -pitch transducer uses 61 emissions and a maximum steering angle of 20° for depths from 0 to 60 mm. The achieved lateral full-width at half-maximum (FWHM) is 1.5λ and the contrast is -29 dB for a scatterer at 9 mm ( 24λ ). Using a λ /2-pitch transducer and only 21 emissions within the same angle range, the image quality is improved in terms of contrast, which is -37 dB. For imaging in regions deeper than 25 mm ( 66λ ), only 21 emissions are optimal for both the transducers, resulting in a -36 dB contrast at 34 mm ( 90λ ). Measurements are performed using the experimental SARUS scanner connected to a λ -pitch and λ /2-pitch transducer. A wire phantom and a tissue mimicking phantom containing anechoic cysts are scanned and show the performance using the optimized sequences for the transducers. FWHM is 1.6λ and contrast is -25 dB for a wire at 9 mm using the λ -pitch transducer. For the λ /2-pitch transducer, contrast is -29 dB. In vivo scans of the carotid artery of a healthy volunteer show improved contrast and present fewer artifacts, when using the λ /2-pitch transducer compared with the λ -pitch. It is demonstrated with a frame rate, which is three times higher for the λ /2-pitch transducer.
Basiri, Abbas; Zare, Samad; Tabibi, Ali; Sharifiaghdas, Farzaneh; Aminsharifi, Alireza; Mousavi-Bahar, Seyed Habibollah; Ahmadnia, Hassan
2010-09-01
Since there is insufficient evidence to determine the best treatment modality in children with distal ureteral calculi, we designed a multicenter, randomized, controlled trial to evaluate the efficacy and complications of transureteral and shock wave lithotripsy in these patients. A total of 100 children with distal ureteral calculi were included in the study. Of the patients 50 were randomized consecutively to undergo shock wave lithotripsy using a Compact Delta II lithotriptor (Dornier MedTech, Kennesaw, Georgia), and 50 were randomized to undergo transureteral lithotripsy with holmium laser and pneumatic lithotriptor between February 2007 and October 2009. Stone-free, complication and efficiency quotient rates were assessed in each group. Mean +/- SD patient age was 6.5 +/- 3.7 years (range 1 to 13). Mean stone surface was 35 mm(2) in the transureteral group and 37 mm(2) in the shock wave lithotripsy group. Stone-free rates at 2 weeks after transureteral lithotripsy and single session shock wave lithotripsy differed significantly, at 78% and 56%, respectively (p = 0.004). With 2 sessions of shock wave lithotripsy the stone-free rate increased to 72%. Efficiency quotient was significantly higher for transureteral vs shock wave lithotripsy (81% vs 62%, p = 0.001). Minor complications were comparable and negligible between the groups. Two patients (4%) who underwent transureteral lithotripsy sustained a ureteral perforation. In the short term it seems that transureteral and shock wave lithotripsy are acceptable modalities for the treatment of distal ureteral calculi in children. However, transureteral lithotripsy has a higher efficacy rate when performed meticulously by experienced hands using appropriate instruments. 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Hisasue, Shin-ichi; China, Toshiyuki; Horiuchi, Akira; Kimura, Masaki; Saito, Keisuke; Isotani, Shuji; Ide, Hisamitsu; Muto, Satoru; Yamaguchi, Raizo; Horie, Shigeo
2016-01-01
To evaluate the efficacy of low-intensity shock wave therapy and to identify the predictive factors of its efficacy in Japanese patients with erectile dysfunction. The present study included 57 patients with erectile dysfunction who satisfied all the following conditions: more than 6-months history of erectile dysfunction, sexual health inventory for men score of ≤ 12 without phosphodiesterase type-5 inhibitor, erection hardness score grade 1 or 2, mean penile circumferential change by erectometer assessing sleep related erection of < 25 mm and non-neurological pathology. Patients were treated by a low-energy shock waves generator (ED1000; Medispec, Gaithersburg, MD, USA). A total of 12 shock wave treatments were applied. Sexual health inventory for men score, erection hardness score with or without phosphodiesterase type-5 inhibitor, and mean penile circumferential change were assessed at baseline, 1, 3 and 6 months after the termination of low-intensity shock wave therapy. Of 57 patients who were assigned for the low-intensity shock wave therapy trial, 56 patients were analyzed. Patients had a median age of 64 years. The sexual health inventory for men and erection hardness score (with and without phosphodiesterase type-5 inhibitor) were significantly increased (P < 0.001) at each time-point. The mean penile circumferential change was also increased from 13.1 to 20.2 mm after low-intensity shock wave therapy (P < 0.001). In the multivariate analysis, age and the number of concomitant comorbidities were statistically significant predictors for the efficacy. Low-intensity shock wave therapy seems to be an effective physical therapy for erectile dysfunction. Age and comorbidities are negative predictive factors of therapeutic response. © 2015 The Japanese Urological Association.
Wang, Ching-Jen; Yang, Kuender D; Wang, Feng-Sheng; Hsu, Chia-Chen; Chen, Hsiang-Ho
2004-01-01
Shock wave treatment is believed to improve bone healing after fracture. The purpose of this study was to evaluate the effect of shock wave treatment on bone mass and bone strength after fracture of the femur in a rabbit model. A standardized closed fracture of the right femur was created with a three-point bending method in 24 New Zealand white rabbits. Animals were randomly divided into three groups: (1) control (no shock wave treatment), (2) low-energy (shock wave treatment at 0.18 mJ/mm2 energy flux density with 2000 impulses), and (3) high-energy (shock wave treatment at 0.47 mJ/mm2 energy flux density with 4000 impulses). Bone mass (bone mineral density (BMD), callus formation, ash and calcium contents) and bone strength (peak load, peak stress and modulus of elasticity) were assessed at 12 and 24 weeks after shock wave treatment. While the BMD values of the high-energy group were significantly higher than the control group (P = 0.021), the BMD values between the low-energy and control groups were not statistically significant (P = 0.358). The high-energy group showed significantly more callus formation (P < 0.001), higher ash content (P < 0.001) and calcium content (P = 0.003) than the control and low-energy groups. With regard to bone strength, the high-energy group showed significantly higher peak load (P = 0.012), peak stress (P = 0.015) and modulus of elasticity (P = 0.011) than the low-energy and control groups. Overall, the effect of shock wave treatment on bone mass and bone strength appears to be dose dependent in acute fracture healing in rabbits.
NASA Astrophysics Data System (ADS)
Guo, Mengchao; Zhou, Kan; Wang, Xiaokun; Zhuang, Haiyan; Tang, Dongming; Zhang, Baoshan; Yang, Yi
2018-04-01
In this paper, the impact of coupling between unit cells on the performance of linear-to-circular polarization conversion metamaterial with half transmission and half reflection is analyzed by changing the distance between the unit cells. An equivalent electrical circuit model is then built to explain it based on the analysis. The simulated results show that, when the distance between the unit cells is 23 mm, this metamaterial converts half of the incident linearly-polarized wave into reflected left-hand circularly-polarized wave and converts the other half of it into transmitted left-hand circularly-polarized wave at 4.4 GHz; when the distance is 28 mm, this metamaterial reflects all of the incident linearly-polarized wave at 4.4 GHz; and when the distance is 32 mm, this metamaterial converts half of the incident linearly-polarized wave into reflected right-hand circularly-polarized wave and converts the other half of it into transmitted right-hand circularly-polarized wave at 4.4 GHz. The tunability is realized successfully. The analysis shows that the changes of coupling between unit cells lead to the changes of performance of this metamaterial. The coupling between the unit cells is then considered when building the equivalent electrical circuit model. The built equivalent electrical circuit model can be used to perfectly explain the simulated results, which confirms the validity of it. It can also give help to the design of tunable polarization conversion metamaterials.
Veiga-Lopez, A; Beckett, EM; Abi Salloum, B; Ye, W; Padmanabhan, V
2014-01-01
Developmental exposure to BPA adversely affects reproductive function. In sheep, prenatal BPA treatment induces reproductive neuroendocrine defects, manifested as LH excess and dampened LH surge and perturbs early ovarian gene expression. In this study we hypothesized that prenatal BPA treatment will also disrupt ovarian follicular dynamics. Pregnant sheep were treated from days 30 to 90 of gestation with 3 different BPA doses (0.05, 0.5, or 5 mg/kg BW/day). All female offspring were estrus synchronized and transrectal ultrasonography was performed daily for 22 days to monitor ovarian follicular and corpora lutea dynamics. Blood samples were collected to assess hormonal preovulatory changes and luteal progesterone dynamics. Statistical analysis revealed that the time interval between the estradiol rise and the preovulatory LH surge was shortened in the BPA-treated females. None of the three BPA doses had an effect on corpora lutea, progestogenic cycles, and mean or duration of ovulatory and non-ovulatory follicles. However, differences in follicular count trajectories were evident in all three follicular size classes (2–3 mm, 4–5 mm, and ≥ 6 mm) of prenatal BPA-treated animals compared to controls. Number of follicular waves tended also to be more variable in the prenatal BPA-treated groups ranging from 2 to 5 follicular waves per cycle, while this was restricted to 3 to 4 waves in control females. These changes in ovarian follicular dynamics coupled with defects in time interval between estradiol rise and preovulatory LH release are likely to lead to subfertility in prenatal BPA-treated females. PMID:24923655
Oda, Sam Goldy Shoyama; Yamato, Ronaldo Jun; Fedullo, José Daniel Luzes; Leomil Neto, Moacir; Larsson, Maria Helena Matiko Akao
2009-09-01
Thirty-three captive leopard cats, Leopardus tigrinus, were anesthetized with xylazine (1-2 mg/kg) and ketamine (10 mg/kg), and electrocardiograph (ECG) tests were recorded in all leads with 1 cm = 1 mV sensibility and 25 mm/sec speed repeating DII lead at 50 mm/sec speed with the same sensibility. Results expressed by mean and standard deviation were: heart rate (HR) = 107 +/- 17 (bpm); P-wave = 0.048 +/- 0.072 (s) x 0.128 +/- 0.048 (mV); PR interval = 0.101 +/- 0.081 (s); QRS compound = 0.053 +/- 0.012 (s) x 1.446 +/- 0.602 (mV); QT interval = 0.231 +/- 0.028 (s); R-wave (CV6LL) = 1.574 +/- 0.527 (mV); R-wave (CV6LU) = 1.583 +/- 0.818 (mV); heart rhythm: normal sinus rhythm (15.2%), sinus rhythm with wandering pacemaker (WPM) (60.6%), sinus arrhythmia with WPM (24.2%); electric axis: between +30 degrees and +60 degrees (6.1%), +60 (6.1%), between +60 degrees and +90 degrees (57.6%), +90 degrees (9%), between +90 degrees and +120 degrees (21.2%); ST segment: normal (75.7%), elevation (18.2%), depression (6.1%); T-wave polarity (DII): positive (100%); T-wave (V10): absent (6.1%), negative (63.6%), positive (18.2%), and with interference (12.1%). Through ECG data comparison with other species, unique features of Leopardus tigrinus' (leopard cat) ECG parameters were detected. Some of the study animals presented with an R-wave amplitude that was indicative of left ventricle overload according to patterns for normal domestic cats (Felis cati). Echocardiographic exams revealed normal heart cavities' function and morphology. The aim of this study was to establish some electrocardiographic parameters of captive L. tigrinus.
Path loss analysis in millimeter wave cellular systems for urban mobile communications
NASA Astrophysics Data System (ADS)
Rajagopalan, Ramesh; Hoffman, Mitchell
2016-09-01
The proliferation in the number of mobile devices and developments in cellular technology has led to an ever increasing demand for mobile data. The global bandwidth shortage facing wireless carriers today has motivated research for fifth generation (5G) cellular systems. In recent years, millimeter wave (mmW) frequencies between 30 and 300 GHz are being considered as a promising technology for 5G systems. Such systems can offer superior user experience by providing data rates that exceed one Gigabit per second and latencies lower than a millisecond. However, there is little research about cellular mmW propagation in densely populated urban environments. Understanding the radio channel is a primary requirement for optimal design of mmW systems. Radio propagation in mmW systems faces significant challenges due to rapidly varying channel conditions and intermittent connectivity. In this paper, we study the propagation of mmW spectrum in an urban environment. We use a statistical model to simulate an urban environment with diverse building distributions. We perform extensive simulations to analyze the path loss behavior for both line of sight (LOS) and non line of sight (NLOS) conditions for 28 GHZ and 73 GHZ mmW frequencies. We observe that the path loss approximates a logarithmic fit for both LOS and NLOS environments. Our simulations show that the omnidirectional free space path loss is approximately 30 dB higher for mmW systems compared to current 3G PP cellular systems. To address this challenge, we propose using highly directional horn antennas with beam forming for reducing the path loss.
Shear wave elasticity imaging based on acoustic radiation force and optical detection.
Cheng, Yi; Li, Rui; Li, Sinan; Dunsby, Christopher; Eckersley, Robert J; Elson, Daniel S; Tang, Meng-Xing
2012-09-01
Tissue elasticity is closely related to the velocity of shear waves within biologic tissue. Shear waves can be generated by an acoustic radiation force and tracked by, e.g., ultrasound or magnetic resonance imaging (MRI) measurements. This has been shown to be able to noninvasively map tissue elasticity in depth and has great potential in a wide range of clinical applications including cancer and cardiovascular diseases. In this study, a highly sensitive optical measurement technique is proposed as an alternative way to track shear waves generated by the acoustic radiation force. A charge coupled device (CCD) camera was used to capture diffuse photons from tissue mimicking phantoms illuminated by a laser source at 532 nm. CCD images were recorded at different delays after the transmission of an ultrasound burst and were processed to obtain the time of flight for the shear wave. A differential measurement scheme involving generation of shear waves at two different positions was used to improve the accuracy and spatial resolution of the system. The results from measurements on both homogeneous and heterogeneous phantoms were compared with measurements from other instruments and demonstrate the feasibility and accuracy of the technique for imaging and quantifying elasticity. The relative error in estimation of shear wave velocity can be as low as 3.3% with a spatial resolution of 2 mm, and increases to 8.8% with a spatial resolution of 1 mm for the medium stiffness phantom. The system is shown to be highly sensitive and is able to track shear waves propagating over several centimetres given the ultrasound excitation amplitude and the phantom material used in this study. It was also found that the reflection of shear waves from boundaries between regions with different elastic properties can cause significant bias in the estimation of elasticity, which also applies to other shear wave tracking techniques. This bias can be reduced at the expense of reduced spatial resolution. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Heterodyne Detection in MM & Sub-mm Waves Developed at Paris Observatory
NASA Astrophysics Data System (ADS)
Beaudin, G.; Encrenaz, P.
Millimeter and submillimeter-wave observations provide important informations for the studies of atmospheric chemistry and of astrochemistry (molecular clouds, stars formation, galactic study, comets and cosmology). But, these observations depend strongly on instrumentation techniques and on the site quality. New techniques or higher detector performances result in unprecedented observations and sometimes, the observational needs drive developments of new detector technologies, for example, superconducting junctions (SIS mixers) because of its high sensitivity in heterodyne detection in the millimeter and submillimeter wave range (100 GHz - 700 GHz), HEB (Hot Electron Bolometer) mixers which are being developed by several groups for application in THz observations. For the submillimetre wavelengths heterodyne receivers, the local oscillator (LO) is still a critical element. So far, solid state sources are often not powerful enough for most of the applications at millimetre or sub-millimetre wavelengths: large efforts using new planar components and integrated circuits on membrane substrate or new techniques (photomixing, QCL) are now in progress in few groups. The new large projects as SOFIA, Herschel, ALMA and the post-Herschel missions for astronomy, the other projects for aeronomy, meteorology (Megha-tropiques-Saphir) and for planetary science (ROSETTA, Mars exploration, ...), will benefit from the new developments to hunt more molecules.
Shaping Ability of Single-file Systems with Different Movements: A Micro-computed Tomographic Study.
Santa-Rosa, Joedy; de Sousa-Neto, Manoel Damião; Versiani, Marco Aurelio; Nevares, Giselle; Xavier, Felipe; Romeiro, Kaline; Cassimiro, Marcely; Leoni, Graziela Bianchi; de Menezes, Rebeca Ferraz; Albuquerque, Diana
2016-01-01
This study aimed to perform a rigorous sample standardization and also evaluate the preparation of mesiobuccal (MB) root canals of maxillary molars with severe curvatures using two single-file engine-driven systems (WaveOne with reciprocating motion and OneShape with rotary movement), using micro-computed tomography (micro-CT). Ten MB roots with single canals were included, uniformly distributed into two groups (n=5). The samples were prepared with a WaveOne or OneShape files. The shaping ability and amount of canal transportation were assessed by a comparison of the pre- and post-instrumentation micro-CT scans. The Kolmogorov-Smirnov and t-tests were used for statistical analysis. The level of significance was set at 0.05. Instrumentation of canals increased their surface area and volume. Canal transportation occurred in coronal, middle and apical thirds and no statistical difference was observed between the two systems (P>0.05). In apical third, significant differences were found between groups in canal roundness (in 3 mm level) and perimeter (in 3 and 4 mm levels) (P<0.05). The WaveOne and One Shape single-file systems were able to shape curved root canals, producing minor changes in the canal curvature.
Flow Visualization of a Rotating Detonation Engine
2016-10-05
2[b]), and a 3-dimensional (3-D) view around the injectors (2[c]). In this study, ethylene and oxygen were used as propellants. These gases were fed...1.0-mm radius; the ethylene injectors had a 0.8-mm radius. A total of 100 sets of injectors were installed at even intervals. The gases were injected...detonation wave, was filled with high-pressure, high-temperature burned gas. This high-pressure burned gas stopped the injection of ethylene and
Jegger, David; da Silva, Rafaela; Jeanrenaud, Xavier; Nasratullah, Mohammad; Tevaearai, Hendrik; von Segesser, Ludwig K; Segers, Patrick; Gaillard, Virginie; Atkinson, Jeffrey; Lartaud, Isabelle; Stergiopulo, Nikolaos
2006-10-01
The vitamin D(3) and nicotine (VDN) model is one of isolated systolic hypertension (ISH) in which arterial calcification raises arterial stiffness and vascular impedance. The effects of VDN treatment on arterial and cardiac hemodynamics have been investigated; however, a complete analysis of ventricular-arterial interaction is lacking. Wistar rats were treated with VDN (VDN group, n = 9), and a control group (n = 10) was included without the VDN. At week 8, invasive indexes of cardiac function were obtained using a conductance catheter. Simultaneously, aortic pressure and flow were measured to derive vascular impedance and characterize ventricular-vascular interaction. VDN caused significant increases in systolic (138 +/- 6 vs. 116 +/- 13 mmHg, P < 0.01) and pulse (42 +/- 10 vs. 26 +/- 4 mmHg, P < 0.01) pressures with respect to control. Total arterial compliance decreased (0.12 +/- 0.08 vs. 0.21 +/- 0.04 ml/mmHg in control, P < 0.05), and pulse wave velocity increased significantly (8.8 +/- 2.5 vs. 5.1 +/- 2.0 m/s in control, P < 0.05). The arterial elastance and end-systolic elastance rose significantly in the VDN group (P < 0.05). Wave reflection was augmented in the VDN group, as reflected by the increase in the wave reflection coefficient (0.63 +/- 0.06 vs. 0.52 +/- 0.05 in control, P < 0.05) and the amplitude of the reflected pressure wave (13.3 +/- 3.1 vs. 8.4 +/- 1.0 mmHg in control, P < 0.05). We studied ventricular-arterial coupling in a VDN-induced rat model of reduced arterial compliance. The VDN treatment led to development of ISH and provoked alterations in cardiac function, arterial impedance, arterial function, and ventricular-arterial interaction, which in many aspects are similar to effects of an aged and stiffened arterial tree.
Andersson, Charlotte; Lyass, Asya; Larson, Martin G; Spartano, Nicole L; Vita, Joseph A; Benjamin, Emelia J; Murabito, Joanne M; Esliger, Dale W; Blease, Susan J; Hamburg, Naomi M; Mitchell, Gary F; Vasan, Ramachandran S
2015-03-19
Physical activity is associated with several health benefits, including lower cardiovascular disease risk. The independent influence of physical activity on cardiac and vascular function in the community, however, has been sparsely investigated. We related objective measures of moderate- to vigorous-intensity physical activity (MVPA, assessed by accelerometry) to cardiac and vascular indices in 2376 participants of the Framingham Heart Study third generation cohort (54% women, mean age 47 years). Using multivariable regression models, we related MVPA to the following echocardiographic and vascular measures: left ventricular mass, left atrial and aortic root sizes, carotid-femoral pulse wave velocity, augmentation index, and forward pressure wave. Men and women engaged in MVPA 29.9±21.4 and 25.5±19.4 min/day, respectively. Higher values of MVPA (per 10-minute increment) were associated with lower carotid-femoral pulse wave velocity (estimate -0.53 ms/m; P=0.006) and lower forward pressure wave (estimate -0.23 mm Hg; P=0.03) but were not associated with augmentation index (estimate 0.13%; P=0.25). MVPA was associated positively with log(e) left ventricular mass (estimate 0.006 log(e) [g/m(2)]; P=0.0003), left ventricular wall thickness (estimate 0.07 mm; P=0.0001), and left atrial dimension (estimate 0.10 mm; P=0.01). MVPA also tended to be positively associated with aortic root dimension (estimate 0.05 mm; P=0.052). Associations of MVPA with cardiovascular measures were similar, in general, for bouts lasting <10 versus ≥10 minutes. In our community-based sample, greater physical activity was associated with lower vascular stiffness but with higher echocardiographic left ventricular mass and left atrial size. These findings suggest complex relations of usual levels of physical activity and cardiovascular remodeling. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Functional Vascular Study in Hypertensive Subjects with Type 2 Diabetes Using Losartan or Amlodipine
Pozzobon, Cesar Romaro; Gismondi, Ronaldo A. O. C.; Bedirian, Ricardo; Ladeira, Marcia Cristina; Neves, Mario Fritsch; Oigman, Wille
2014-01-01
Background Antihypertensive drugs are used to control blood pressure (BP) and reduce macro- and microvascular complications in hypertensive patients with diabetes. Objectives The present study aimed to compare the functional vascular changes in hypertensive patients with type 2 diabetes mellitus after 6 weeks of treatment with amlodipine or losartan. Methods Patients with a previous diagnosis of hypertension and type 2 diabetes mellitus were randomly divided into 2 groups and evaluated after 6 weeks of treatment with amlodipine (5 mg/day) or losartan (100 mg/day). Patient evaluation included BP measurement, ambulatory BP monitoring, and assessment of vascular parameters using applanation tonometry, pulse wave velocity (PWV), and flow-mediated dilation (FMD) of the brachial artery. Results A total of 42 patients were evaluated (21 in each group), with a predominance of women (71%) in both groups. The mean age of the patients in both groups was similar (amlodipine group: 54.9 ± 4.5 years; losartan group: 54.0 ± 6.9 years), with no significant difference in the mean BP [amlodipine group: 145 ± 14 mmHg (systolic) and 84 ± 8 mmHg (diastolic); losartan group: 153 ± 19 mmHg (systolic) and 90 ± 9 mmHg (diastolic)]. The augmentation index (30% ± 9% and 36% ± 8%, p = 0.025) and augmentation pressure (16 ± 6 mmHg and 20 ± 8 mmHg, p = 0.045) were lower in the amlodipine group when compared with the losartan group. PWV and FMD were similar in both groups. Conclusions Hypertensive patients with type 2 diabetes mellitus treated with amlodipine exhibited an improved pattern of pulse wave reflection in comparison with those treated with losartan. However, the use of losartan may be associated with independent vascular reactivity to the pressor effect. PMID:25014057
Pozzobon, Cesar Romaro; Gismondi, Ronaldo A O C; Bedirian, Ricardo; Ladeira, Marcia Cristina; Neves, Mario Fritsch; Oigman, Wille
2014-07-01
Antihypertensive drugs are used to control blood pressure (BP) and reduce macro- and microvascular complications in hypertensive patients with diabetes. The present study aimed to compare the functional vascular changes in hypertensive patients with type 2 diabetes mellitus after 6 weeks of treatment with amlodipine or losartan. Patients with a previous diagnosis of hypertension and type 2 diabetes mellitus were randomly divided into 2 groups and evaluated after 6 weeks of treatment with amlodipine (5 mg/day) or losartan (100 mg/day). Patient evaluation included BP measurement, ambulatory BP monitoring, and assessment of vascular parameters using applanation tonometry, pulse wave velocity (PWV), and flow-mediated dilation (FMD) of the brachial artery. A total of 42 patients were evaluated (21 in each group), with a predominance of women (71%) in both groups. The mean age of the patients in both groups was similar (amlodipine group: 54.9 ± 4.5 years; losartan group: 54.0 ± 6.9 years), with no significant difference in the mean BP [amlodipine group: 145 ± 14 mmHg (systolic) and 84 ± 8 mmHg (diastolic); losartan group: 153 ± 19 mmHg (systolic) and 90 ± 9 mmHg (diastolic)]. The augmentation index (30% ± 9% and 36% ± 8%, p = 0.025) and augmentation pressure (16 ± 6 mmHg and 20 ± 8 mmHg, p = 0.045) were lower in the amlodipine group when compared with the losartan group. PWV and FMD were similar in both groups. Hypertensive patients with type 2 diabetes mellitus treated with amlodipine exhibited an improved pattern of pulse wave reflection in comparison with those treated with losartan. However, the use of losartan may be associated with independent vascular reactivity to the pressor effect.
Matter-wave coherence limit owing to cosmic gravitational wave background
NASA Astrophysics Data System (ADS)
Steane, Andrew M.
2017-12-01
We study matter-wave interferometry in the presence of a stochastic background of gravitational waves. It is shown that if the background has a scale-invariant spectrum over a wide bandwidth (which is expected in a class of inflationary models of Big Bang cosmology), then separated-path interference cannot be observed for a lump of matter of size above a limit which is very insensitive to the strength and bandwidth of the fluctuations, unless the interferometer is servo-controlled or otherwise protected. For ordinary solid matter this limit is of order 1-10 mm. A servo-controlled or cross-correlated device would also exhibit limits to the observation of macroscopic interference, which we estimate for ordinary matter moving at speeds small compared to c.
High-power terahertz quantum cascade lasers with ∼0.23 W in continuous wave mode
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Xuemin; Shen, Changle; Jiang, Tao
2016-07-15
Terahertz quantum cascade lasers with a record output power up to ∼0.23 W in continuous wave mode were obtained. We show that the optimal 2.9-mm-long device operating at 3.11 THz has a low threshold current density of 270 A/cm{sup 2} at ∼15 K. The maximum operating temperature arrived at ∼65 K in continuous wave mode and the internal quantum efficiencies decreased from 0.53 to 0.19 for the devices with different cavity lengths. By using one convex lens with the effective focal length of 13 mm, the beam profile was collimated to be a quasi Gaussian distribution.
Millimeter wave sensor requirements for maritime small craft identification
NASA Astrophysics Data System (ADS)
Krapels, Keith; Driggers, Ronald G.; Garcia, Jose; Boettcher, Evelyn; Prather, Dennis; Schuetz, Chrisopher; Samluk, Jesse; Stein, Lee; Kiser, William; Visnansky, Andrew; Grata, Jeremy; Wikner, David; Harris, Russ
2009-09-01
Passive millimeter wave (mmW) imagers have improved in terms of resolution sensitivity and frame rate. Currently, the Office of Naval Research (ONR), along with the US Army Research, Development and Engineering Command, Communications Electronics Research Development and Engineering Center (RDECOM CERDEC) Night Vision and Electronic Sensor Directorate (NVESD), are investigating the current state-of-the-art of mmW imaging systems. The focus of this study was the performance of mmW imaging systems for the task of small watercraft / boat identification field performance. First mmW signatures were collected. This consisted of a set of eight small watercrafts; at 5 different aspects, during the daylight hours over a 48 hour period in the spring of 2008. Target characteristics were measured and characteristic dimension, signatures, and Root Sum Squared of Target's Temperature (RRSΔT) tabulated. Then an eight-alternative, forced choice (8AFC) human perception experiment was developed and conducted at NVESD. The ability of observers to discriminate between small watercraft was quantified. Next, the task difficulty criterion, V50, was quantified by applying this data to NVESD's target acquisition models using the Targeting Task Performance (TTP) metric. These parameters can be used to evaluate sensor field performance for Anti-Terrorism / Force Protection (AT/FP) and navigation tasks for the U.S. Navy, as well as for design and evaluation of imaging passive mmW sensors for both the U.S. Navy and U.S. Coast Guard.
The gyrotron - a natural source of high-power orbital angular momentum millimeter-wave beams
NASA Astrophysics Data System (ADS)
Thumm, M.; Sawant, A.; Choe, M. S.; Choi, E. M.
2017-08-01
Orbital angular momentum (OAM) of electromagnetic-wave beams provides further diversity to multiplexing in wireless communication. The present report shows that higher-order mode gyrotrons are natural sources of high-power OAM millimeter (mm) wave beams. The well-defined OAM of their rotating cavity modes operating at near cutoff frequency has been derived by photonic and electromagnetic wave approaches.
Beig, Jahangir Rashid; Tramboo, Nisar A; Rather, Hilal A; Hafeez, Imran; Ananth, Vijai; Lone, Ajaz A; Yaqoob, Irfan; Bhat, Irfan A; Ali, Muzaffar
2015-12-01
Mitral stenosis (MS) is associated with prolonged inter- and intra-atrial electromechanical delays and increased P-wave dispersion, which are markers of atrial fibrillation (AF) risk. This study was conducted to assess the immediate effect of successful percutaneous transvenous mitral commissurotomy (PTMC) on these parameters. This single center observational study included 25 patients with severe MS (aged 34.1 ± 7.1 years, with mean mitral valve area (MVA) of 0.74 ± 0.13 cm(2)), in sinus rhythm, who underwent successful PTMC at our hospital. P-wave dispersion (PWD) was calculated by subtracting minimum P-wave duration (P min) from maximum P-wave duration (Pmax), measured on a 12-lead surface ECG obtained from each patient in supine position at a paper speed of 50mm/s and 20mm/mV. Inter-atrial (AEMD), left intra-atrial (L-IAEMD), and right intra-atrial (R-IAEMD) electromechanical delays were measured on tissue Doppler imaging. PTMC was performed using the standard Inoue Balloon technique. All these parameters were evaluated and compared before and 24-48 h after PTMC. Successful PTMC led to significant reduction in AEMD (p < 0.001), L-IAEMD (p < 0.001), and R-IAEMD (p < 0.001). There were no changes in Pmax, Pmin, and PWD immediately after PTMC. Successful PTMC has a favorable early impact on inter- and intra-atrial electromechanical delays, which are considered as novel parameters of atrial electromechanical remodeling in MS patients. Prospective large-scale studies are required to confirm whether improvement in these markers translates into reduced long-term AF risk. Copyright © 2015 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Beig, Jahangir Rashid; Tramboo, Nisar A.; Rather, Hilal A.; Hafeez, Imran; Ananth, Vijai; Lone, Ajaz A.; Yaqoob, Irfan; Bhat, Irfan A.; Ali, Muzaffar
2015-01-01
Background Mitral stenosis (MS) is associated with prolonged inter- and intra-atrial electromechanical delays and increased P-wave dispersion, which are markers of atrial fibrillation (AF) risk. This study was conducted to assess the immediate effect of successful percutaneous transvenous mitral commissurotomy (PTMC) on these parameters. Methods This single center observational study included 25 patients with severe MS (aged 34.1 ± 7.1 years, with mean mitral valve area (MVA) of 0.74 ± 0.13 cm2), in sinus rhythm, who underwent successful PTMC at our hospital. P-wave dispersion (PWD) was calculated by subtracting minimum P-wave duration (Pmin) from maximum P-wave duration (Pmax), measured on a 12-lead surface ECG obtained from each patient in supine position at a paper speed of 50 mm/s and 20 mm/mV. Inter-atrial (AEMD), left intra-atrial (L-IAEMD), and right intra-atrial (R-IAEMD) electromechanical delays were measured on tissue Doppler imaging. PTMC was performed using the standard Inoue Balloon technique. All these parameters were evaluated and compared before and 24–48 h after PTMC. Results Successful PTMC led to significant reduction in AEMD (p < 0.001), L-IAEMD (p < 0.001), and R-IAEMD (p < 0.001). There were no changes in Pmax, Pmin, and PWD immediately after PTMC. Conclusions Successful PTMC has a favorable early impact on inter- and intra-atrial electromechanical delays, which are considered as novel parameters of atrial electromechanical remodeling in MS patients. Prospective large-scale studies are required to confirm whether improvement in these markers translates into reduced long-term AF risk. PMID:26688153
NASA Astrophysics Data System (ADS)
Zirak, H.; Jafari, S.
2015-06-01
In this study, a theory of free-electron laser (FEL) with a Langmuir wave wiggler in the presence of an axial magnetic field has been presented. The small wavelength of the plasma wave (in the sub-mm range) allows obtaining higher frequency than conventional wiggler FELs. Electron trajectories have been obtained by solving the equations of motion for a single electron. In addition, a fourth-order Runge-Kutta method has been used to simulate the electron trajectories. Employing a perturbation analysis, the dispersion relation for an electromagnetic and space-charge waves has been derived by solving the momentum transfer, continuity, and wave equations. Numerical calculations show that the growth rate increases with increasing the e-beam energy and e-beam density, while it decreases with increasing the strength of the axial guide magnetic field.
Effect of the specimen length on ultrasonic P-wave velocity in some volcanic rocks and limestones
NASA Astrophysics Data System (ADS)
Karaman, Kadir; Kaya, Ayberk; Kesimal, Ayhan
2015-12-01
Ultrasonic P-wave velocity (UPV) is commonly used in different fields such as civil, mining, geotechnical, and rock engineering. One of the significant parameters which affect the UPV of rock materials is likely to be the length of test cores although it is not mentioned in the literature. In this study, in order to explore the influence of the specimen length on the UPV, rock samples were collected from eight different locations in Turkey. The NX-sized core specimens having different length of 50, 75, 100, 125, and 150 mm were prepared. Before the analyses, rocks were divided into two groups in terms of their geological origins such as volcanic and chemical sedimentary (limestone) rocks. The UPV tests were carried out under dry and saturated conditions for each 200 core specimens. By evaluating the test results, it was shown that the length of the specimens significantly affects the UPV values. Based on the regression analyses, a method was developed to determine the threshold specimen length of studied rocks. Fluctuations in UPVdry and UPVsat values were generally observed for cores smaller than the threshold specimen length. In this study, the threshold specimen length was determined as 79 mm for volcanic rocks and 109 mm for limestones.
Experimental investigation of shock wave diffraction over a single- or double-sphere model
NASA Astrophysics Data System (ADS)
Zhang, L. T.; Wang, T. H.; Hao, L. N.; Huang, B. Q.; Chen, W. J.; Shi, H. H.
2017-01-01
In this study, the unsteady drag produced by the interaction of a shock wave with a single- and a double-sphere model is measured using imbedded accelerometers. The shock wave is generated in a horizontal circular shock tube with an inner diameter of 200 mm. The effect of the shock Mach number and the dimensionless distance between spheres is investigated. The time-history of the drag coefficient is obtained based on Fast Fourier Transformation (FFT) band-block filtering and polynomial fitting of the measured acceleration. The measured peak values of the drag coefficient, with the associated uncertainty, are reported.
Khudus, Muhammad I M Abdul; Lee, Timothy; Horak, Peter; Brambilla, Gilberto
2015-04-01
We investigate the effect of intrinsic surface roughness associated to frozen thermal oscillations from the fiber fabrication process on the efficiency of third-harmonic generation via intermodal phase matching in silica nanofibers. Already a periodic wave with roughness of 0.2 nm reduces the efficiency by roughly 50% in a 1-mm optical nanofiber, with the divergence growing quadratically with distance. The surface wave period does not exhibit a large impact on the efficiency, due to averaging effects. However, both the location of the surface waves with respect to the phase matching radius as well as the surface wave amplitude have substantial effect on the efficiency, with the former presenting the possibility of transferring the power back to the pump wavelength. Simulations with a realistic superposition of random surface waves indicate that the conversion efficiency increases only for a few mm of propagation and reaches a maximum of less than 1%.
Cyclic Fatigue Resistance of Reciproc, WaveOne, and WaveOne Gold Nickel-Titanium Instruments.
Özyürek, Taha
2016-10-01
The purpose of this study was to compare the cyclic fatigue resistance of Reciproc R25 (VDW, Munich, Germany), WaveOne Primary (Dentsply Maillefer, Ballaigues, Switzerland), and WaveOne Gold Primary files (Dentsply Maillefer). Twenty Reciproc R25, 20 WaveOne Primary, and 20 WaveOne Gold Primary instruments were included in this study. The cyclic fatigue tests were performed using a cyclic fatigue testing device, which has an artificial stainless steel canal with a 60° angle of curvature and a 5-mm radius of curvature. The files were randomly divided into 3 groups (group 1: Reciproc R25; group 2: WaveOne Primary; and group 3: WaveOne Gold Primary). All the instruments were rotated until fracture occurred, and the time to fracture was recorded in seconds using a digital chronometer. The number of cycles to failure (NCF) was calculated. The data were analyzed statistically (P < .05). There was a significant difference among the groups (P < .05). The WaveOne Gold Primary showed the greatest mean of NCF (1628 ± 107), and the WaveOne Primary showed the lowest mean of NCF (1153 ± 119.2). Within the limitations of this in vitro study, the cyclic fatigue resistance of the WaveOne Gold Primary single-file system was higher than the WaveOne Primary and Reciproc R25 single-file instruments. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
AlGhatrif, Majd; Strait, James B.; Morrell, Chris; Canepa, Marco; Wright, Jeanette; Elango, Palchamy; Scuteri, Angelo; Najjar, Samer S.; Ferrucci, Luigi; Lakatta, Edward G.
2013-01-01
Carotid-femoral pulse wave velocity (PWV), a marker of arterial stiffness, is an established independent cardiovascular (CV) risk factor. Little information is available on the pattern and determinants of the longitudinal change in PWV with aging. Such information is crucial to elucidating mechanisms underlying arterial stiffness and the design of interventions to retard it. Between 1988 and 2013, we collected 2 to 9 serial measures of PWV in 354 men and 423 women of the Baltimore Longitudinal Study of Aging, who were 21 to 94 years of age and free of clinically significant CV disease. Rates of PWV increase accelerated with advancing age in men more than women, leading to gender differences in PWV after the age of 50. In both sexes, not only systolic blood pressure (SBP) ≥140mmHg, but also SBP of 120–139mmHg was associated with steeper rates of PWV increase compared to SBP<120mmHg. Furthermore, there was a dose-dependent effect SBP in men with marked acceleration in PWV rate of increase with age at SBP ≥140mmHg compared to SBP of 120–139mmHg. Except for waist circumference in women, no other traditional CV risk factors predicted longitudinal PWV increase. In conclusion, the steeper longitudinal increase of PWV in men than women led to gender difference that expanded with advancing age. Age and systolic blood pressure are the main longitudinal determinants of pulse wave velocity and the effect of systolic blood pressure on PWV trajectories exists even in the pre-hypertensive range. PMID:24001897
Extremely low-frequency Lamb wave band gaps in a sandwich phononic crystal thin plate
NASA Astrophysics Data System (ADS)
Shen, Li; Wu, Jiu Hui; Liu, Zhangyi; Fu, Gang
2015-11-01
In this paper, a kind of sandwich phononic crystal (PC) plate with silicon rubber scatterers embedded in polymethyl methacrylate (PMMA) matrix is proposed to demonstrate its low-frequency Lamb wave band gap (BG) characteristics. The dispersion relationship and the displacement vector fields of the basic slab modes and the locally resonant modes are investigated to show the BG formation mechanism. The anti-symmetric Lamb wave BG is further studied due to its important function in reducing vibration. The analysis on the BG characteristics of the PC through changing their geometrical parameters is performed. By optimizing the structure, a sandwich PC plate with a thickness of only 3 mm and a lower boundary (as low as 23.9 Hz) of the first anti-symmetric BG is designed. Finally, sound insulation experiment on a sandwich PC plate with the thickness of only 2.5 mm is conducted, showing satisfactory noise reduction effect in the frequency range of the anti-symmetric Lamb BG. Therefore, this kind of sandwich PC plate has potential applications in controlling vibration and noise in low-frequency ranges.
Sonoluminescence in an Acoustically Levitated Water Filled Shell
NASA Astrophysics Data System (ADS)
Rivera, P. J.; Stephens, R. B.; Jones, J. P.
1998-11-01
The possibility of using shells levitated by acoustic waves to improve the conditions to study sonoluminescence was conducted. Single bubble sonoluminescence (SBSL) was generated using a 2 mm diameter water filled plastic shell, supported in air with 1 MHz sound waves. The bubble was generated and compressed with a separate transducer emitting pulsed 5 MHz acoustic waves which were focussed on the center of the suspended shell. This approach is considerably different from the typical generation technique of SBSL in that the acoustic power is coupled through the air rather than by a solid bond to the container. With this configuration, the water container can be substantially reduced in size and the luminescence pulse rate is probably not connected with cavity resonances. As a result, optical access to the spark is improved, water attenuation is reduced (water thickness ~1 mm), and repetition rate can be considerably higher. This geometry presents problems and opportunities in controlling the gas content and temperature of the water. It might also be sensitive to the perfection of the enclosing plastic shell, so success is erratic. Details will be discussed.
Dynamic cycling in atrial size and flow during obstructive apnoea
Pressman, Gregg S; Cepeda-Valery, Beatriz; Codolosa, Nicolas; Orban, Marek; Samuel, Solomon P; Somers, Virend K
2016-01-01
Objective Obstructive sleep apnoea (OSA) is strongly associated with cardiovascular disease. However, acute cardiovascular effects of repetitive airway obstruction are poorly understood. While past research used a sustained Mueller manoeuver to simulate OSA we employed a series of gasping efforts to better simulate true obstructive apnoeas. This report describes acute changes in cardiac anatomy and flow related to sudden changes in intrathoracic pressure. Methods and results 26 healthy, normal weight participants performed 5–6 gasping efforts (target intrathoracic pressure −40 mm Hg) while undergoing Doppler echocardiography. 14 participants had sufficient echocardiographic images to allow comparison of atrial areas during the manoeuver with baseline measurements. Mitral and tricuspid E-wave and A-wave velocities postmanoeuver were compared with baseline in all participants. Average atrial areas changed little during the manoeuver, but variance in both atrial areas was significantly greater than baseline. Further, an inverse relationship was noted with left atrial collapse and right atrial enlargement at onset of inspiratory effort. Significant inverse changes were noted in Doppler flow when comparing the first beat postmanoeuver (pMM1) with baseline. Mitral E-wave velocity increased 9.1 cm/s while tricuspid E-wave velocity decreased 7.0 cm/s; by the eighth beat postmanoeuver (pMM8) values were not different from baseline. Mitral and tricuspid A-wave velocities were not different from baseline at pMM1, but both were significantly higher by pMM8. Conclusions Repetitive obstructive apnoeas produce dynamic, inverse changes in atrial size and Doppler flow across the atrioventricular valves. These observations have important implications for understanding the pathophysiology of OSA. PMID:27127636
Large Blast and Thermal Simulator Reflected Wave Eliminator Study
1990-03-01
it delays the passage of this wave through the test section until after the test is complete. The required length of extra duct depends on the strength...tube axis, which acts like an additional contraction effect since Se = Sj/[Cqsin(aj)]. Tii extra area is illustrated best by plotting (Se-Ae)/Ac versus...34Simulation de Choc et de Soaffie. Comimpensateur d’Ondes de Detente de Bouche pour tube a Choc de 2400 mm de diametre de Veine. Description, Compte- Renda
Resent Status of ITER Equatorial Launcher Development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takahashi, K.; Kajiwara, K.; Kasugai, A.
2009-11-26
The ITER equatorial launcher is divided into a front shield and a port plug. The front shield is composed of fourteen blanket shield modules so as to form three openings for the injection of mm-wave beams into plasma. Twenty-four waveguide transmission lines, internal shields, cooling pipes and so on are installed in the port plug. The transmission lines consist of the corrugated waveguides, miter bends and the free space propagation region utilizing two mirrors in front of the waveguide outlet. The analysis of mm-wave beam propagation in the region shows that the transmission efficiency more than 99.5% is attained. Themore » high power experiments of the launcher mock-up have been carried out and the measured field patterns at each mirror and the outlet of the launcher are agreed with the calculations. It is concluded that the transmission line components in the launcher mock-up are fabricated as designed and the present mm-wave design in the launcher is feasible.« less
Millimeter wave coherent synchrotron radiation in a compact electron storage ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murphy, J.B.; Blum, E.; Heese, R.
1998-01-01
Installation of a 2,856 MHz RF system into the XLS compact electron storage ring would allow the generation of millimeter wave coherent synchrotron radiation. Operating at 150 MeV, one could produce bunches containing on the order of 2 {times} 10{sup 7} electrons with a bunch length {sigma}{sub L0} = 0.3 mm, resulting in coherent emission at wavelengths above 0.8 mm. The characteristics of the source and the emitted radiation are discussed. In the case of 100 mrad horizontal collection angle, the average power radiated in the wavelength band 1 mm {le} {lambda} {le} 2 mm is 0.3 mW for singlemore » bunch operation and 24 mW for 80 bunch operation. The peak power in a single pulse of a few picosecond duration is on the order of one watt. By reducing the momentum compaction, the bunch length could be reduced to {sigma}{sub L0} = 0.15 mm, resulting in coherent synchrotron radiation down to 500 {micro}m.« less
Sound pressure distribution within natural and artificial human ear canals: Forward stimulation
Ravicz, Michael E.; Tao Cheng, Jeffrey; Rosowski, John J.
2014-01-01
This work is part of a study of the interaction of sound pressure in the ear canal (EC) with tympanic membrane (TM) surface displacement. Sound pressures were measured with 0.5–2 mm spacing at three locations within the shortened natural EC or an artificial EC in human temporal bones: near the TM surface, within the tympanic ring plane, and in a plane transverse to the long axis of the EC. Sound pressure was also measured at 2-mm intervals along the long EC axis. The sound field is described well by the size and direction of planar sound pressure gradients, the location and orientation of standing-wave nodal lines, and the location of longitudinal standing waves along the EC axis. Standing-wave nodal lines perpendicular to the long EC axis are present on the TM surface >11–16 kHz in the natural or artificial EC. The range of sound pressures was larger in the tympanic ring plane than at the TM surface or in the transverse EC plane. Longitudinal standing-wave patterns were stretched. The tympanic-ring sound field is a useful approximation of the TM sound field, and the artificial EC approximates the natural EC. PMID:25480061
NASA Astrophysics Data System (ADS)
Mustapha, Samir; Ye, Lin; Dong, Xingjian; Alamdari, Mehrisadat Makki
2016-08-01
Barely visible indentation damage after quasi-static indentation in sandwich CF/EP composites was assessed using ultrasonic guided wave signals. Finite element analyses were conducted to investigate the interaction between guided waves and damage, further to assist in the selection process of the Lamb wave sensitive modes for debonding identification. Composite sandwich beams and panels structures were investigated. Using the beam structure, a damage index was defined based on the change in the peak magnitude of the captured wave signals before and after the indentation, and the damage index was correlated with the residual deformation (defined as the depth of the dent), that was further correlated with the amount of crushing within the core. Both A0 and S0 Lamb wave modes showed high sensitivity to the presence of barely visible indentation damage with residual deformation of 0.2 mm. Furthermore, barely visible indentation damage was assessed in composite sandwich panels after indenting to 3 and 5 mm, and the damage index was defined, based on (a) the peak magnitude of the wave signals before and after indentation or (b) the mismatch between the original and reconstructed wave signals based on a time-reversal algorithm, and was subsequently applied to locate the position of indentation.
Treadmill walking with load carriage increases aortic pressure wave reflection.
Ribeiro, Fernando; Oliveira, Nórton L; Pires, Joana; Alves, Alberto J; Oliveira, José
2014-01-01
The study examined the effects of treadmill walking with load carriage on derived measures of central pressure and augmentation index in young healthy subjects. Fourteen male subjects (age 31.0 ± 1.0 years) volunteered in this study. Subjects walked 10 minutes on a treadmill at a speed of 5 km/h carrying no load during one session and a load of 10% of their body weight on both upper limbs in two water carboys with handle during the other session. Pulse wave analysis was performed at rest and immediately after exercise in the radial artery of the right upper limb by applanation tonometry. The main result indicates that walking with load carriage sharply increased augmentation index at 75 bpm (-5.5 ± 2.2 to -1.4 ± 2.2% vs. -5.2 ± 2.8 to -5.5 ± 2.1%, p<0.05), and also induced twice as high increments in central pulse pressure (7.4 ± 1.5 vs. 3.1 ± 1.4 mmHg, p<0.05) and peripheral (20.5 ± 2.7 vs. 10.3 ± 2.5 mmHg, p<0.05) and central systolic pressure (14.7 ± 2.1 vs. 7.4 ± 2.0 mmHg, p<0.05). Walking with additional load of 10% of their body weight (aerobic exercise accompanied by upper limb isometric contraction) increases derived measures of central pressure and augmentation index, an index of wave reflection and arterial stiffness. Copyright © 2013 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.
Lapp, Robert T; Wolf, J Stuart; Faerber, Gary J; Roberts, William W; McCarthy, Sean T; Anderson, Michelle A; Wamsteker, Erik-Jan; Elta, Grace H; Scheiman, James M; Kwon, Richard S
2016-09-01
The need for endoscopic therapy before extracorporeal shock wave lithotripsy (SWL) to facilitate pancreatic duct stone removal is unclear. Predictive factors associated with successful fragmentation and subsequent complete duct clearance are variable. We hypothesize pancreatic duct strictures and large stones, but not pre-SWL endotherapy, correlate with successful fragmentation and complete duct clearance. A retrospective cohort study of patients with pancreaticolithiasis who underwent SWL and endoscopic retrograde cholangiopancreatography between January 2009 and June 2014 was evaluated. Thirty-seven patients were treated. Technical success (TS) of fragmentation was achieved in 22 patients (60%). Technical success was associated with fewer stones and SWL sessions and smaller stone and duct size. By multivariate logistic regression, only duct dilation was associated with TS. Endoscopic success of complete duct clearance was achieved in 29 patients (80%). Endoscopic success was more frequent with stones 12 mm or less and with successful TS. By multivariate logistic regression, stones greater than 12 mm were associated with endoscopic failure. Pre-SWL endotherapy does not affect stone fragmentation. Patients with a dilated duct (>8 mm) and pancreatic stones 12 mm or greater were associated with unsuccessful TS and endoscopic success, respectively, and may benefit from early referral for surgical decompression.
Detection and monitoring of shear crack growth using S-P conversion of seismic waves
NASA Astrophysics Data System (ADS)
Modiriasari, A.; Bobet, A.; Pyrak-Nolte, L. J.
2017-12-01
A diagnostic method for monitoring shear crack initiation, propagation, and coalescence in rock is key for the detection of major rupture events, such as slip along a fault. Active ultrasonic monitoring was used in this study to determine the precursory signatures to shear crack initiation in pre-cracked rock. Prismatic specimens of Indiana limestone (203x2101x638x1 mm) with two pre-existing parallel flaws were subjected to uniaxial compression. The flaws were cut through the thickness of the specimen using a scroll saw. The length of the flaws was 19.05 mm and had an inclination angle with respect to the loading direction of 30o. Shear wave transducers were placed on each side of the specimen, with polarization parallel to the loading direction. The shear waves, given the geometry of the flaws, were normally incident to the shear crack forming between the two flaws during loading. Shear crack initiation and propagation was detected on the specimen surface using digital image correlation (DIC), while initiation inside the rock was monitored by measuring full waveforms of the transmitted and reflected shear (S) waves across the specimen. Prior to the detection of a shear crack on the specimen surface using DIC, transmitted S waves were converted to compressional (P) waves. The emergence of converted S-P wave occurs because of the presence of oriented microcracks inside the rock. The microcracks coalesce and form the shear crack observed on the specimen surface. Up to crack coalescence, the amplitude of the converted waves increased with shear crack propagation. However, the amplitude of the transmitted shear waves between the two flaws did not change with shear crack initiation and propagation. This is in agreement with the conversion of elastic waves (P- to S-wave or S- to P-wave) observed by Nakagawa et al., (2000) for normal incident waves. Elastic wave conversions are attributed to the formation of an array of oriented microcracks that dilate under shear stress, which causes energy partitioning into P, S, and P-to-S or S-to-P waves. This finding provides a diagnostic method for detecting shear crack initiation and growth using seismic wave conversions. Acknowledgments: This material is based upon work supported by the National Science Foundation, Geomechanics and Geotechnical Systems Program (award No. CMMI-1162082).
Sarica, Kemal; Kafkasli, Alper; Yazici, Özgür; Çetinel, Ali Cihangir; Demirkol, Mehmet Kutlu; Tuncer, Murat; Şahin, Cahit; Eryildirim, Bilal
2015-02-01
The aim of the study was to determine the possible predictive value of certain patient- and stone-related factors on the stone-free rates and auxiliary procedures after extracorporeal shock wave lithotripsy in patients with impacted proximal ureteral calculi. A total of 111 patients (86 male, 25 females M/F: 3.44/1) with impacted proximal ureteral stones treated with shock wave lithotripsy were evaluated. Cases were retrieved from a departmental shock wave lithotripsy database. Variables analyzed included BMI of the case, diameter of proximal ureter and renal pelvis, stone size and Hounsfield unit, ureteral wall thickness at the impacted stone site. Stone-free status on follow-up imaging at 3 months was considered a successful outcome. All patients had a single impacted proximal ureteral stone. While the mean age of the cases was 46 ± 13 years (range 26-79 years), mean stone size was 8.95 mm (5.3-15.1 mm). Following shock wave lithotripsy although 87 patients (78.4%) were completely stone-free at 3-month follow-up visit, 24 (21.6%) cases had residual fragments requiring further repeat procedures. Prediction of the final outcome of SWL in patients with impacted proximal ureteral stones is a challenging issue and our data did clearly indicate a highly significant relationship between ureteral wall thickness and the success rates of shock wave lithotripsy particularly in cases requiring additional procedures. Of all the evaluated stone- and patient-related factors, only ureteral wall thickness at the impacted stone site independently predicted shock wave lithotripsy success.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veiga-Lopez, A.; Beckett, E.M.; Abi Salloum, B.
Developmental exposure to BPA adversely affects reproductive function. In sheep, prenatal BPA treatment induces reproductive neuroendocrine defects, manifested as LH excess and dampened LH surge and perturbs early ovarian gene expression. In this study we hypothesized that prenatal BPA treatment will also disrupt ovarian follicular dynamics. Pregnant sheep were treated from days 30 to 90 of gestation with 3 different BPA doses (0.05, 0.5, or 5 mg/kg BW/day). All female offspring were estrus synchronized and transrectal ultrasonography was performed daily for 22 days to monitor ovarian follicular and corpora lutea dynamics. Blood samples were collected to assess preovulatory hormonal changesmore » and luteal progesterone dynamics. Statistical analysis revealed that the time interval between the estradiol rise and the preovulatory LH surge was shortened in the BPA-treated females. None of the three BPA doses had an effect on corpora lutea, progestogenic cycles, and mean number or duration of ovulatory and non-ovulatory follicles. However, differences in follicular count trajectories were evident in all three follicular size classes (2–3 mm, 4–5 mm, and ≥ 6 mm) of prenatal BPA-treated animals compared to controls. Number of follicular waves tended also to be more variable in the prenatal BPA-treated groups ranging from 2 to 5 follicular waves per cycle, while this was restricted to 3 to 4 waves in control females. These changes in ovarian follicular dynamics coupled with defects in time interval between estradiol rise and preovulatory LH release are likely to lead to subfertility in prenatal BPA-treated females. - Highlights: • Prenatal BPA shortens interval between estradiol rise and preovulatory LH surge. • Prenatal BPA affects follicular count trajectory and follicular wave occurrence. • Prenatal BPA does not affect ovulatory rate and progesterone dynamics.« less
Nagy, Anikó Ilona; Venkateshvaran, Ashwin; Merkely, Béla; Lund, Lars H; Manouras, Aristomenis
2017-01-01
The diastolic pulmonary pressure gradient (DPG) has recently been introduced as a specific marker of combined pre-capillary pulmonary hypertension (Cpc-PH) in left heart disease (LHD). However, its diagnostic and prognostic superiority compared with traditional haemodynamic indices has been challenged lately. Current recommendations explicitly denote that in the normal heart, DPG values are greater than zero, with DPG ≥7 mmHg indicating Cpc-PH. However, clinicians are perplexed by the frequent observation of DPG <0 mmHg (DPG NEG ), as its physiological explanation and clinical impact are unclear to date. We hypothesized that large V-waves in the pulmonary artery wedge pressure (PAWP) curve yielding asymmetric pressure transmission might account for DPG NEG and undertook this study to clarify the physiological and prognostic implications of DPG NEG . Right heart catheterization and echocardiography were performed in 316 patients with LHD due to primary myocardial dysfunction or valvular disease. A total of 256 patients had PH-LHD, of whom 48% demonstrated DPG NEG . The V-wave amplitude inversely correlated with DPG (r = -0.45, P < 0.001) in patients with low pulmonary vascular resistance (PVR), but not in those with elevated PVR (P > 0.05). Patients with large V-waves had negative and lower DPG than those without augmented V-waves (P < 0.001) despite similar PVR (P >0.05). Positive, but normal DPG (0-6 mmHg) carried a worse 2-year prognosis for death and/or heart transplantation than DPG NEG (hazard ratio 2.97; P < 0.05). Our results advocate against DPG NEG constituting a measurement error. We propose that DPG NEG can partially be ascribed to large V-waves and carries a better prognosis than DPG within the normal positive range. © 2016 The Authors. European Journal of Heart Failure © 2016 European Society of Cardiology.
Taki, Hirofumi; Nagatani, Yoshiki; Matsukawa, Mami; Kanai, Hiroshi; Izumi, Shin-Ichi
2017-10-01
Ultrasound signals that pass through cancellous bone may be considered to consist of two longitudinal waves, which are called fast and slow waves. Accurate decomposition of these fast and slow waves is considered to be highly beneficial in determination of the characteristics of cancellous bone. In the present study, a fast decomposition method using a wave transfer function with a phase rotation parameter was applied to received signals that have passed through bovine bone specimens with various bone volume to total volume (BV/TV) ratios in a simulation study, where the elastic finite-difference time-domain method is used and the ultrasound wave propagated parallel to the bone axes. The proposed method succeeded to decompose both fast and slow waves accurately; the normalized residual intensity was less than -19.5 dB when the specimen thickness ranged from 4 to 7 mm and the BV/TV value ranged from 0.144 to 0.226. There was a strong relationship between the phase rotation value and the BV/TV value. The ratio of the peak envelope amplitude of the decomposed fast wave to that of the slow wave increased monotonically with increasing BV/TV ratio, indicating the high performance of the proposed method in estimation of the BV/TV value in cancellous bone.
An optical mm-wave generation scheme by frequency octupling using a nested MMI
NASA Astrophysics Data System (ADS)
Shang, Lei; Wen, Aijun; Li, Bo; Wang, Tonggang; Chen, Yang; Li, Ming'an
2011-12-01
A novel method of a filterless optical millimeter-wave (MMW) signal generation with frequency octupling via a nested multimode interference (MMI) coupler is proposed for Radio-over-fiber systems. By setting the DC bias voltage applied to the central arms of MMI-b and MMI-c accurately, the optical carrier can be completely suppressed. The OSSR can be as high as about 58 dB without optical filter and the radio frequency spurious suppression ratio (RFSSR) exceeds 32 dB, which is the best result as we know. Simulation results suggest that when the generated optical mm-wave signal is transmitted along the standard single-mode fiber, the eye diagram is still opened after being transmitted over a 50 km fiber.
Pressure measurements of a three wave journal air bearing
NASA Technical Reports Server (NTRS)
Dimofte, Florin; Addy, Harold E., Jr.
1994-01-01
In order to validate theoretical predictions of a wave journal bearing concept, a bench test rig was assembled at NASA Lewis Research Center to measure the steady-state performance of a journal air bearing. The tester can run up to 30,000 RPM and the spindle has a run out of less than 1 micron. A three wave journal bearing (50 mm diameter and 58 mm length) has been machined at NASA Lewis. The pressures at 16 ports along the bearing circumference at the middle of the bearing length were measured and compared to the theoretical prediction. The bearing ran at speeds up to 15,000 RPM and certain loads. Good agreement was found between the measured and calculated pressures.
Focusing of shock waves induced by optical breakdown in water
Sankin, Georgy N.; Zhou, Yufeng; Zhong, Pei
2008-01-01
The focusing of laser-generated shock waves by a truncated ellipsoidal reflector was experimentally and numerically investigated. Pressure waveform and distribution around the first (F1) and second foci (F2) of the ellipsoidal reflector were measured. A neodymium doped yttrium aluminum garnet laser of 1046 nm wavelength and 5 ns pulse duration was used to create an optical breakdown at F1, which generates a spherically diverging shock wave with a peak pressure of 2.1–5.9 MPa at 1.1 mm stand-off distance and a pulse width at half maximum of 36–65 ns. Upon reflection, a converging shock wave is produced which, upon arriving at F2, has a leading compressive wave with a peak pressure of 26 MPa and a zero-crossing pulse duration of 0.1 μs, followed by a trailing tensile wave of −3.3 MPa peak pressure and 0.2 μs pulse duration. The −6 dB beam size of the focused shock wave field is 1.6×0.2 mm2 along and transverse to the shock wave propagation direction. Formation of elongated plasmas at high laser energy levels limits the increase in the peak pressure at F2. General features in the waveform profile of the converging shock wave are in qualitative agreement with numerical simulations based on the Hamilton model. PMID:18537359
High-frequency ultrasound Doppler system for biomedical applications with a 30-MHz linear array.
Xu, Xiaochen; Sun, Lei; Cannata, Jonathan M; Yen, Jesse T; Shung, K Kirk
2008-04-01
In this paper, we report the development of the first high-frequency (HF) pulsed-wave Doppler system using a 30-MHz linear array transducer to assess the cardiovascular functions in small animals. This array-based pulsed-wave Doppler system included a 16-channel HF analog beamformer, a HF pulsed-wave Doppler module, timing circuits, HF bipolar pulsers and analog front ends. The beamformed echoes acquired by the 16-channel analog beamformer were fed directly to the HF pulsed-wave Doppler module. Then the in-phase and quadrature-phase (IQ) audio Doppler signals were digitized by either a sound card or a Gage digitizer and stored in a personal computer. The Doppler spectrogram was displayed on a personal computer in real time. The two-way beamwidths were determined to be 160 microm to 320 microm when the array was electronically focused at different focal points at depths from 5 to 10 mm. A micro-flow phantom, consisting of a polyimide tube with an inner diameter of 127 microm and the wire phantom were used to evaluate and calibrate the system. The results show that the system is capable of detecting motion velocity of the wire phantom as low as 0.1 mm/s, and detecting blood-mimicking flow velocity in the 127-microm tube lower than 7 mm/s. The system was subsequently used to measure the blood flow in vivo in two mouse abdominal superficial vessels, with diameters of approximately 200 microm, and a mouse aorta close to the heart. These results demonstrated that this system may become an indispensable part of the current HF array-based imaging systems for small animal studies.
Baumgartner, Jill; Carter, Ellison; Schauer, James J; Ezzati, Majid; Daskalopoulou, Stella S; Valois, Marie-France; Shan, Ming; Yang, Xudong
2018-02-09
We evaluated the exposure-response associations between personal exposure to air pollution from biomass stoves and multiple vascular and haemodynamic parameters in rural Chinese women. We analysed the baseline information from a longitudinal study in southwestern China. Women's brachial and central blood pressure and pulse pressure, carotid-femoral pulse wave velocity and augmentation index, and their 48-hour personal exposures to fine particulate matter (PM 2.5 ) and black carbon were measured in summer and winter. We evaluated the associations between exposure to air pollution and haemodynamic parameters using mixed-effects regression models adjusted for known cardiovascular risk factors. Women's (n=205, ages 27-86 years) exposures to PM 2.5 and black carbon ranged from 14 µg/m 3 to 1405 µg/m 3 and 0.1-121.8 µg/m 3 , respectively. Among women aged ≥50 years, increased PM 2.5 exposure was associated with higher systolic (brachial: 3.5 mm Hg (P=0.05); central: 4.4 mm Hg (P=0.005)) and diastolic blood pressure (central: 1.3 mm Hg (P=0.10)), higher pulse pressure (peripheral: 2.5 mm Hg (P=0.05); central: 2.9 mm Hg (P=0.008)) and lower peripheral-central pulse pressure amplification (-0.007 (P=0.04)). Among younger women, the associations were inconsistent in the direction of effect and not statistically significant. Increased PM 2.5 exposure was associated with no difference in pulse wave velocity and modestly higher augmentation index though the CI included zero (1.1%; 95% CI -0.2% to 2.4%). Similar associations were found for black carbon exposure. Exposure to household air pollution was associated with higher blood pressure and central haemodynamics in older Chinese women, with no associations observed with pulse wave velocity. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Electric Field Tunable Microwave and MM-wave Ferrite Devices
2010-04-30
xm thick YIG film grown by liquid-phase epitaxy on a (111) gadolinium gallium garnet was used. A PZT plate with the dimensions 4x1x0.5 mm3 was...of width ~ 150 micron and length 20 mm. An YIG film , 6 u.m thick, 0.5 mm in width and 2.5 mm long, grown on a 0.5 mm thick gadolinium gallium garnet ...yttrium iron garnet film and a ceramic barium strontium titanate slab. The electrical tunability of the differential phase shift Acp is achieved through
NASA Technical Reports Server (NTRS)
Wintucky, Edwin G.; Simons, Rainee N.
2015-01-01
This paper presents the design, fabrication and test results for a novel waveguide multimode directional coupler (MDC). The coupler, fabricated from two dissimilar frequency band waveguides, is capable of isolating power at the second harmonic frequency from the fundamental power at the output port of a traveling-wave tube (TWT) amplifier. Test results from proof-of-concept demonstrations are presented for a Ku-band/Ka-band MDC and a Ka-band/E-band MDC. In addition to power measurements at harmonic frequencies, a potential application of the MDC is in the design of a satellite borne beacon source for atmospheric propagation studies at millimeter-wave (mm-wave) frequencies (Ka-band and E-band).
NASA Astrophysics Data System (ADS)
Sahai, R.; Claussen, M. J.; Schnee, S.; Morris, M. R.; Sánchez Contreras, C.
2011-09-01
We report the results of a pilot multiwavelength survey in the radio continuum (X, Ka, and Q bands, i.e., from 3.6 cm to 7 mm) carried out with the Expanded Very Large Array (EVLA) in order to confirm the presence of very large dust grains in dusty disks and torii around the central stars in a small sample of post-asymptotic giant branch (pAGB) objects, as inferred from millimeter (mm) and submillimeter (submm) observations. Supporting mm-wave observations were also obtained with the Combined Array for Research in Millimeter-wave Astronomy toward three of our sources. Our EVLA survey has resulted in a robust detection of our most prominent submm emission source, the pre-planetary nebula (PPN) IRAS 22036+5306, in all three bands, and the disk-prominent pAGB object, RV Tau, in one band. The observed fluxes are consistent with optically thin free-free emission, and since they are insignificant compared to their submm/mm fluxes, we conclude that the latter must come from substantial masses of cool, large (mm-sized) grains. We find that the power-law emissivity in the cm-to-submm range for the large grains in IRAS22036 is νβ, with β = 1-1.3. Furthermore, the value of β in the 3-0.85 mm range for the three disk-prominent pAGB sources (β <= 0.4) is significantly lower than that of IRAS22036, suggesting that the grains in pAGB objects with circumbinary disks are likely larger than those in the dusty waists of pre-planetary nebulae.
Song, Junho; Pulkkinen, Aki; Huang, Yuexi; Hynynen, Kullervo
2014-01-01
Standing wave formation in an ex vivo human skull was investigated using a clinical prototype of a 30 cm diameter with 15 cm radius of curvature, low frequency (230 kHz), hemispherical transcranial Magnetic Resonance guided Focused Ultrasound (MRgFUS) phased-array. Experimental and simulation studies were conducted with changing aperture size and f-number configurations of the phased array, and qualitatively and quantitatively examined the acoustic pressure variation at the focus due to standing waves. The results demonstrated that the nodes and anti-nodes of standing wave produced by the small aperture array were clearly seen at approximately every 3 mm. The effect of the standing wave became more pronounced as the focus was moved closer to skull base. However, a sharp focus was seen for the full array, and there was no such standing wave pattern in the acoustic plane or near the skull base. This study showed that the fluctuation pressure amplitude would be greatly reduced by using a large-scale, hemispherical phased array with a low f-number. PMID:22049360
Generation of ramp waves using variable areal density flyers
NASA Astrophysics Data System (ADS)
Winter, R. E.; Cotton, M.; Harris, E. J.; Chapman, D. J.; Eakins, D.
2016-07-01
Ramp loading using graded density impactors as flyers in gas-gun-driven plate impact experiments can yield new and useful information about the equation of state and the strength properties of the loaded material. Selective Laser Melting, an additive manufacturing technique, was used to manufacture a graded density flyer, termed the "bed-of-nails" (BON). A 2.5-mm-thick × 99.4-mm-diameter solid disc of stainless steel formed a base for an array of tapered spikes of length 5.5 mm and spaced 1 mm apart. The two experiments to test the concept were performed at impact velocities of 900 and 1100 m/s using the 100-mm gas gun at the Institute of Shock Physics at Imperial College London. In each experiment, a BON flyer was impacted onto a copper buffer plate which helped to smooth out perturbations in the wave profile. The ramp delivered to the copper buffer was in turn transmitted to three tantalum targets of thicknesses 3, 5 and 7 mm, which were mounted in contact with the back face of the copper. Heterodyne velocimetry (Het-V) was used to measure the velocity-time history, at the back faces of the tantalum discs. The wave profiles display a smooth increase in velocity over a period of ˜ 2.5 μs, with no indication of a shock jump. The measured profiles have been analysed to generate a stress vs. volume curve for tantalum. The results have been compared with the predictions of the Sandia National Laboratories hydrocode, CTH.
Surveillance of cardiovascular risk in the normotensive patient with repaired aortic coarctation
Swan, Lorna; Kraidly, Mustafa; Muhll, Isabelle Vonder; Collins, Peter; Gatzoulis, Michael A.
2010-01-01
Background Repaired coarctation of the aorta is associated with premature atherosclerosis and an increased risk of cardiovascular events even in normotensive subjects. To date clinical risk stratification has focused on brachial blood pressures ignoring the complex pulsatility of the aortic wave form. The aim of this study was to assess components of this pulsatility in a clinical setting and to suggest possible techniques to improve risk stratification. Methods This was a prospective study recruiting patients from a tertiary referral centre. Pulse wave morphology was assessed using applanation tonometry. B-mode ultrasound and cardiac magnetic resonance were used to assess carotid intimal–medial thickness and left ventricular mass. Results Forty-six subjects with repaired coarctation of the aorta (range 16–62 years; mean 31 years) and 20 matched controls were studied. Baseline brachial systolic and diastolic blood pressures were not statistically different between the 2 groups. Peripheral (62.5 mmHg (11.3) vs. 50.6 mmHg (15.0), p = 0.0008) and central (34.5 mmHg (7.7) vs. 28.7 mmHg (4.7), p = 0.005) pulse pressures were elevated in the coarctation patients compared to controls. The reflected pressure wave returned to the ascending aorta earlier in the coarctation group (p = 0.007) and the tension time index (TTI) was increased (p = 0.03). The sub-endocardial viability index (SVI) was reduced in the coarctation subjects (159 (33) vs. 186 (31)%; p = 0.009) but there was no differences in central augmentation index (p = 0.35). Conclusions This study demonstrates that there are patients with repaired coarctation who have an excellent mid-term outcome free from ventricular hypertrophy, carotid intima medial thickening and with relatively preserved vascular reactivity. However even in this “best outcome” cohort there were abnormal vascular characteristics that may predispose to increased cardiovascular risk. Simple non-invasive investigations can more extensively characterise these sub-clinical abnormalities and by utilised in long-term surveillance. PMID:19059656
A 2x2 W-Band Reference Time-Shifted Phase-Locked Transmitter Array in 65nm CMOS Technology
NASA Technical Reports Server (NTRS)
Tang, Adrian; Virbila, Gabriel; Hsiao, Frank; Wu, Hao; Murphy, David; Mehdi, Imran; Siegel, P. H.; Chang, M-C. Frank
2013-01-01
This paper presents a complete 2x2 phased array transmitter system operating at W-band (90-95 GHz) which employs a PLL reference time-shifting approach instead of using traditional mm-wave phase shifters. PLL reference shifting enables a phased array to be distributed over multiple chips without the need for coherent mm-wave signal distribution between chips. The proposed phased array transmitter system consumes 248 mW per array element when implemented in a 65 nm CMOS technology.
Yang, Zhiyong; Heeger, David J.; Blake, Randolph
2014-01-01
Traveling waves of cortical activity, in which local stimulation triggers lateral spread of activity to distal locations, have been hypothesized to play an important role in cortical function. However, there is conflicting physiological evidence for the existence of spreading traveling waves of neural activity triggered locally. Dichoptic stimulation, in which the two eyes view dissimilar monocular patterns, can lead to dynamic wave-like fluctuations in visual perception and therefore, provides a promising means for identifying and studying cortical traveling waves. Here, we used voltage-sensitive dye imaging to test for the existence of traveling waves of activity in the primary visual cortex of awake, fixating monkeys viewing dichoptic stimuli. We find clear traveling waves that are initiated by brief, localized contrast increments in one of the monocular patterns and then, propagate at speeds of ∼30 mm/s. These results demonstrate that under an appropriate visual context, circuitry in visual cortex in alert animals is capable of supporting long-range traveling waves triggered by local stimulation. PMID:25343785
Balvantín, A J; Diosdado-De-la-Peña, J A; Limon-Leyva, P A; Hernández-Rodríguez, E
2018-02-01
In this work, fundamental symmetric Lamb wave S0 mode is characterized in terms of its velocity variation as function of the interfacial conditions between solid bodies in contact. Imperfect contact conditions are numerically and experimentally determined by using ultrasonic Lamb wave propagation parameters. For the study, an experimental system was used, formed by two solid aluminum rods (25.4mm in diameter) axially loading a thin aluminum plate to control contact interfacial stiffness. The axially applied load on the aluminum plate was varied from 0MPa to 10MPa. Experimental Lamb wave signals were excited on the plate through two longitudinal contact transducers (1MHz of central frequency) using a pitch-catch configuration. Numerical simulations of contact conditions and Lamb wave propagation were performed through Finite Element Analysis (FEA) in commercial software, ANSYS 15®. Simulated Lamb wave signals were generated by means of a 5 cycles tone burst signals with different frequency values. Results indicate a velocity change in both, experimental and simulated Lamb wave signals as function of the applied load. Finally, a comparison between numerical results and experimental measurements was performed obtaining a good agreement. Copyright © 2017 Elsevier B.V. All rights reserved.
Lee, Seung-Heon; Lu, Jian; Lee, Seung-Jun; Han, Jae-Hyun; Jeong, Chan-Uk; Lee, Seung-Chul; Li, Xian; Jazbinšek, Mojca; Yoon, Woojin; Yun, Hoseop; Kang, Bong Joo; Rotermund, Fabian; Nelson, Keith A; Kwon, O-Pil
2017-08-01
Highly efficient nonlinear optical organic crystals are very attractive for various photonic applications including terahertz (THz) wave generation. Up to now, only two classes of ionic crystals based on either pyridinium or quinolinium with extremely large macroscopic optical nonlinearity have been developed. This study reports on a new class of organic nonlinear optical crystals introducing electron-accepting benzothiazolium, which exhibit higher electron-withdrawing strength than pyridinium and quinolinium in benchmark crystals. The benzothiazolium crystals consisting of new acentric core HMB (2-(4-hydroxy-3-methoxystyryl)-3-methylbenzo[d]thiazol-3-ium) exhibit extremely large macroscopic optical nonlinearity with optimal molecular ordering for maximizing the diagonal second-order nonlinearity. HMB-based single crystals prepared by simple cleaving method satisfy all required crystal characteristics for intense THz wave generation such as large crystal size with parallel surfaces, moderate thickness and high optical quality with large optical transparency range (580-1620 nm). Optical rectification of 35 fs pulses at the technologically very important wavelength of 800 nm in 0.26 mm thick HMB crystal leads to one order of magnitude higher THz wave generation efficiency with remarkably broader bandwidth compared to standard inorganic 0.5 mm thick ZnTe crystal. Therefore, newly developed HMB crystals introducing benzothiazolium with extremely large macroscopic optical nonlinearity are very promising materials for intense broadband THz wave generation and other nonlinear optical applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Yalcin, E; Keskin Akca, A; Selcuk, B; Kurtaran, A; Akyuz, M
2012-02-01
Plantar heel pain, a chronic and disabling foot alignment, occurs in the adult population. Extracorporal shock wave therapy (ESWT) offers a nonsurgical option in addition to stretching exercises, heel cups, NSAI, and corticosteroid injections. This study aimed to investigate the effects of ESWT on calcaneal bone spurs and the correlation between clinical outcomes and radiologic changes. The study involved 108 patients with heel pain and radiologically diagnosed heel spurs. All patients underwent ESWT once a week for 5 weeks at the clinic. Each patient received 2,000 impulses of shock waves, starting with 0.05 mJ/mm2 (1.8 bar) and increasing to 0.4 mJ/mm2 (4.0 bar). Standard radiographies of the affected heels were obtained before and after the therapy. Clinical results demonstrated excellent (no pain) in 66.7% of the cases, good (50% of pain reduced) in 15.7% of the cases, and unsatisfactory (no reduction in pain) in 17.6%. After five ESWT treatments, no patients who received shock wave applications had significant spur reductions, but 19 patients (17.6%) had a decrease in the angle of the spur, 23 patients (21.3%) had a decrease in the dimensions of the spur, and one patient had a broken spur. Therefore, results showed no correlation between clinical outcome and radiologic changes. The present study supports the finding that even with no radiologic change after ESWT therapy, the therapy produces significant effects in reducing patients' complaints about heel spurs.
Shear Wave Elastographic Alterations in the Kidney After Extracorporeal Shock Wave Lithotripsy.
Turkay, Rustu; Inci, Ercan; Bas, Derya; Atar, Arda
2018-03-01
Extracorporeal shock wave lithotripsy (ESWL) is a method used frequently for the treatment of renal stone disease. Although its safety is proven, there are still concerns about its unwanted effects on kidneys. In this prospective study, we aimed to evaluate renal tissue alterations with shear wave elastography (SWE) after ESWL. We also studied the correlation between SWE and resistive index (RI) changes. The study included 59 patients who underwent ESWL treatment for renal stone disease. We performed SWE and color Doppler ultrasonography to calculate SWE and RI values before, 1 hour after, and 1 week after lithotripsy treatment. A binary comparison was performed by the Bonferroni test. The correlation between SWE and RI values was evaluated by a Pearson correlation analysis. The patients included 26 women (44.1%) and 33 men (55.9%). Their ages ranged from 20 to 65 years (mean ± SD, 45.0 ± 1.1 years). Stone diameters ranged from 7 to 19 mm (mean, 13.0 ± 0.5 mm). There was a significant difference in SWE values before and 1 hour after lithotripsy treatment (P = .001; P < .01). In the follow-up measurement 1 week after treatment, this difference disappeared (P > .99; P > .05). Resistive index values increased significantly 1 hour after lithotripsy treatment and returned to prelithotripsy values 1 week after treatment. In the correlation analysis, SWE and RI values were not correlated. Measurements of alterations in SWE values after ESWL can provide useful information about renal tissue injury. © 2017 by the American Institute of Ultrasound in Medicine.
Measurement of the depth of narrow slotted sections in eddy current reference standards
NASA Astrophysics Data System (ADS)
Kim, Young-Joo; Kim, Young-gil; Ahn, Bongyoung; Yoon, Dong-Jin
2007-02-01
The dimensions of the slots in eddy current (EC) reference standards are too narrow to be measured by general depth measurement methods such as the optical (laser) or stylus methods. However, measurement of the dimensions of the machined slots is a prerequisite to using the blocks as references. The present paper suggests a measurement method for the slotted section using an ultrasonic test. The width and depth of the slots measured in our study are roughly 0.1 mm and 0.5 mm, respectively. The time of flight (TOF) of the ultrasonic wave was measured precisely. The ultrasonic velocity in the material of the EC reference standard was calculated with the measured values of the TOF and its thickness. Reflected waves from the tip of the slot and the bottom surface of the EC standard were successfully classified. Using this method we have successfully determined the depth of the slotted section.
Retinal pulse wave velocity measurement using spectral-domain optical coherence tomography.
Li, Qian; Li, Lin; Fan, Shanhui; Dai, Cuixia; Chai, Xinyu; Zhou, Chuanqing
2018-02-01
The human eyes provide a natural window for noninvasive measurement of the pulse wave velocity (PWV) of small arteries. By measuring the retinal PWV, the stiffness of small arteries can be assessed, which may better detect early vascular diseases. Therefore, retinal PWV measurement has attracted increasing attention. In this study, a jump-scanning method was proposed for noninvasive measurement of retinal PWV using spectral-domain optical coherence tomography (SD-OCT). The jump-scanning method uses the phase-resolved Doppler OCT to obtain the pulse shapes. To realize PWV measurement, the jump-scanning method extracts the transit time of the pulse wave from an original OCT scanning site to another through a transient jump. The measured retinal arterial PWV of a young human subject with normal blood pressure was in the order of 20 to 30 mm/s, which was consistent with previous studies. As a comparison, PWV of 50 mm/s was measured for a young human subject with prehypertension, which was in accordance with the finding of strong association between retinal PWV and blood pressure. In summary, it is believed the proposed jump-scanning method could benefit the research and diagnosis of vascular diseases through the window of human eyes. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Pulse-driven magnetoimpedance sensor detection of cardiac magnetic activity.
Nakayama, Shinsuke; Sawamura, Kenta; Mohri, Kaneo; Uchiyama, Tsuyoshi
2011-01-01
This study sought to establish a convenient method for detecting biomagnetic activity in the heart. Electrical activity of the heart simultaneously induces a magnetic field. Detection of this magnetic activity will enable non-contact, noninvasive evaluation to be made. We improved the sensitivity of a pulse-driven magnetoimpedance (PMI) sensor, which is used as an electric compass in mobile phones and as a motion sensor of the operation handle in computer games, toward a pico-Tesla (pT) level, and measured magnetic fields on the surface of the thoracic wall in humans. The changes in magnetic field detected by this sensor synchronized with the electric activity of the electrocardiogram (ECG). The shape of the magnetic wave was largely altered by shifting the sensor position within 20 mm in parallel and/or perpendicular to the thoracic wall. The magnetic activity was maximal in the 4th intercostals near the center of the sterna. Furthermore, averaging the magnetic activity at 15 mm in the distance between the thoracic wall and the sensor demonstrated magnetic waves mimicking the P wave and QRS complex. The present study shows the application of PMI sensor in detecting cardiac magnetic activity in several healthy subjects, and suggests future applications of this technology in medicine and biology.
Study on MMW radiation characteristics and imaging of aquatic plants for environmental application
NASA Astrophysics Data System (ADS)
Zhou, Luyan; Zhang, Guangfeng; Liu, Jing
2017-02-01
Working all-day and all-weather, the passive millimeter wave radiometer is widely used in remote sensing, guidance and other fields. In order to solve the increasingly serious problem of water pollution, especially the pollution caused by the rapidly breed of the aquatic plants, a simple and effective method to monitor the water environment is proposed. Aquatic plants can be distinguished through millimeter wave system, as they have high bright temperature compared to Water. The 8mm radiometer is used to measure the radiation characteristics of aquatic plants and image. The simulation results and radiation imaging experiments prove the feasibility and effectively of monitoring aquatic plants by millimeter wave radiometer. This study will contribute to monitoring the aquatic plants growth and decreasing the pollution.
Quantitative evaluation of thickness reduction in corroded steel plates using surface SH waves
NASA Astrophysics Data System (ADS)
Suzuki, Keigo; Ha, Nguyen Phuong; Otobe, Yuichi; Tamura, Hiroshi; Sasaki, Eiichi
2018-04-01
This study evaluates the effect of reduction in plate thickness for a steel plate existing in concrete on guided ultrasonic SH (g-SH) waves. It has been found that the time of flight (TOF) increases if the plate thickness is reduced. The parameter investigated in this study is a delay time obtained from a TOF comparison between a healthy and a damaged plate. The wave propagation is simulated by dynamic Finite Element Analysis (FEA). The resulting data are then used to propose a theoretical equation for predicting TOF. The prediction of delay time obtained from the proposed equation is found to be in general agreement, with an error of 10% (or less), when compared with the experiment results, if the thickness reduction is over 3.65mm.
NASA Astrophysics Data System (ADS)
Chow, C. W.; Yang, L. G.; Yeh, C. H.; Huang, C. B.; Shi, J. W.; Pan, C. L.
2012-10-01
Millimeter-wave (mm-wave) operated in W-band (75 GHz-0.11 THz) is of particular interests, since this frequency band can carry signals at much higher data rates. We demonstrate a 10 Gb/s optical carrier-distributed network with the wireless communication system. The mm-wave signal at carrier frequency of 0.1 THz is generated by a high speed near-ballistic uni-traveling carrier photodiode (NBUTC-PD) based transmitter (Tx), which is optically excited by optical short pulses. The optical pulse source is produced from a self-developed photonic mm-wave waveform generator (PMWG), which allows spectral line-by-line pulse shaping. Hence these optical pulses have high tolerance to fiber chromatic dispersion. The W-band 10 Gb/s wireless data is transmitted and received via a pair of horn antennas. The received 10 Gb/s data is envelope-detected and then used to drive an optical modulator at the remote antenna unit (RAU) to produce the upstream signal sending back to the central office (CO). 20 km single mode fiber (SMF) error free transmission is achieved. Analysis about the optimum repetition rate of the optical pulse source and the transmission performance of the upstream signal are also performed and discussed.
Wang, Yiqun; Pei, Li; Li, Jing; Li, Yueqin
2017-06-10
A full-duplex radio-over-fiber system is proposed, which provides both the generation of a millimeter-wave (mm-wave) signal with tunable frequency multiplication factors (FMFs) and wavelength reuse for uplink data. A dual-driving Mach-Zehnder modulator and a phase modulator are cascaded to form an optical frequency comb. An acousto-optic tunable filter based on a uniform fiber Bragg grating (FBG-AOTF) is employed to select three target optical sidebands. Two symmetrical sidebands are chosen to generate mm waves with tunable FMFs up to 16, which can be adjusted by changing the frequency of the applied acoustic wave. The optical carrier is reused at the base station for uplink connection. FBG-AOTFs driven by two acoustic wave signals are experimentally fabricated and further applied in the proposed scheme. Results of the research indicate that the 2-Gbit/s data can be successfully transmitted over a 25-km single-mode fiber for bidirectional full-duplex channels with power penalty of less than 2.6 dB. The feasibility of the proposed scheme is verified by detailed simulations and partial experiments.
Shock waves: The Maxwell-Cattaneo case.
Uribe, F J
2016-03-01
Several continuum theories for shock waves give rise to a set of differential equations in which the analysis of the underlying vector field can be done using the tools of the theory of dynamical systems. We illustrate the importance of the divergences associated with the vector field by considering the ideas by Maxwell and Cattaneo and apply them to study shock waves in dilute gases. By comparing the predictions of the Maxwell-Cattaneo equations with shock wave experiments we are lead to the following conclusions: (a) For low compressions (low Mach numbers: M) the results from the Maxwell-Cattaneo equations provide profiles that are in fair agreement with the experiments, (b) as the Mach number is increased we find a range of Mach numbers (1.27 ≈ M(1) < M < M(2) ≈ 1.90) such that numerical shock wave solutions to the Maxwell-Cattaneo equations cannot be found, and (c) for greater Mach numbers (M>M_{2}) shock wave solutions can be found though they differ significantly from experiments.
Bartorelli, Antonio L; Serruys, Patrick W; Miquel-Hébert, Karine; Yu, Shui; Pierson, Wes; Stone, Gregg W
2010-07-01
To evaluate the safety and efficacy of the XIENCE V everolimus-eluting stent compared to the TAXUS paclitaxel-eluting stent in small vessels. The XIENCE V everolimus-eluting stent (EES) has been shown to improve angiographic and clinical outcomes after percutaneous myocardial revascularization, but its performance in small coronary arteries has not been investigated. In this pooled analysis, we studied a cohort of 541 patients with small coronary vessels (reference diameter <2.765 mm) by using patient and lesion level data from the SPIRIT II and SPIRIT III studies. TAXUS Express (73% of lesions) and TAXUS Liberté (27% of lesions) paclitaxel-eluting stents (PES) were used as controls in SPIRIT II. In SPIRIT III, Taxus Express(2) PES was the control. Mean angiographic in-stent and in-segment late loss was significantly less in the EES group compared with the PES group, (0.15 +/- 0.37 mm vs. 0.30 +/- 0.44 mm; P = 0.011 for in-stent; 0.10 +/- 0.38 mm vs. 0.21 +/- 0.34 mm; P = 0.034 for in-segment). EES also resulted in a significant reduction in composite major adverse cardiac events at 1 year (19/366 [5.2%] vs. 17/159 [10.7%]; P = 0.037), due to fewer non-Q-wave myocardial infarctions and target lesion revascularizations. At 1 year, the rate of non-Q-wave myocardial infarction was significantly lower in the EES group compared with that of the PES group (6/366 [1.6%] vs. 8/159 [5.0%]; P = 0.037). In patients with small vessel coronary arteries, the XIENCE V EES was superior to the TAXUS PES. (c) 2010 Wiley-Liss, Inc.
Catarino, S O; Minas, G; Miranda, J M
2016-07-01
This paper reports the use of acoustic waves for promoting and improving streaming in tridimensional polymethylmethacrylate (PMMA) cuvettes of 15mm width×14mm height×2.5mm thickness. The acoustic waves are generated by a 28μm thick poly(vinylidene fluoride) - PVDF - piezoelectric transducer in its β phase, actuated at its resonance frequency: 40MHz. The acoustic transmission properties of two materials - SU-8 and polydimethylsiloxane (PDMS) - were numerically compared. It was concluded that PDMS inhibits, while SU-8 allows, the transmission of the acoustic waves to the propagation medium. Therefore, by simulating the acoustic transmission properties of different materials, it is possible to preview the acoustic behavior in the fluidic system, which allows the optimization of the best layout design, saving costs and time. This work also presents a comparison between numerical and experimental results of acoustic streaming obtained with that β-PVDF transducer in the movement and in the formation of fluid recirculation in tridimensional closed domains. Differences between the numerical and experimental results are credited to the high sensitivity of acoustic streaming to the experimental conditions and to limitations of the numerical method. The reported study contributes for the improvement of simulation models that can be extremely useful for predicting the acoustic effects of new materials in fluidic devices, as well as for optimizing the transducers and matching layers positioning in a fluidic structure. Copyright © 2016 Elsevier B.V. All rights reserved.
Role of connexin 43 in the maintenance of spontaneous activity in the guinea pig prostate gland
Dey, Anupa; Kusljic, Snezana; Lang, Richard J; Exintaris, Betty
2010-01-01
BACKGROUND AND PURPOSE To investigate the role of connexin 43 in the maintenance of spontaneous activity in prostate tissue from young and old guinea pigs. EXPERIMENTAL APPROACH Conventional intracellular microelectrode and tension recording techniques, coupled with Western blot analysis and immunohistochemistry for connexin 43 (CX43) were used. The effects of three gap junction uncouplers, 18β glycyrrhetinic acid (10 µM, 40 µM), carbenoxolone (10 µM, 50 µM) and octanol (0.5 mM, 1 mM), were studied in cells displaying slow wave activity and on spontaneously contracting tissue from prostate glands of young (2–5 months) and old (9–16 months) guinea pigs. KEY RESULTS 18β Glycyrrhetinic acid (40 µM), carbenoxolone (50 µM) or octanol (0.5 mM) abolished slow wave activity in prostate tissue from young and old guinea pigs and depolarized membrane potential by approximately 5 mV. These treatments also abolished all contractions in both sets of prostate tissue. These effects were reversed upon washout. Western blot analysis and CX43 immunohistochemistry showed that there was no age-related difference in the expression and distribution of CX43 in prostate tissues. CONCLUSION AND IMPLICATIONS When gap junctional communication via CX43 was disrupted, spontaneous activity was abolished at a cellular and whole tissue level; CX43 is therefore essential for the maintenance of spontaneous slow wave activity and subsequent contractile activity in the guinea pig prostate gland. PMID:20735413
Alrahabi, M; Zafar, M S
2018-06-01
: We compared apical transportation in the WaveOne and ProTaper Next systems, which are rotary nickel-titanium systems with reciprocating and continuous rotation movements, respectively, using manual measurements obtained from resin blocks with simulated root canals and double digital radiographs of extracted teeth. : We used 30 resin blocks with simulated root canals and 30 extracted teeth for this study. The same endodontist performed root canal shaping using the WaveOne or ProTaper Next system. We assessed apical transportation by measuring the amounts (in mm) of material lost 1 mm from the apical foramen in the resin blocks and by using double digital radiography for the extracted teeth. Significant differences between groups were assessed using t-tests. P < 0.05 was considered statistically significant. : The amount of apical transportation differed significantly between the two systems when resin blocks were used for assessment (P < 0.05), but there were no significant differences when extracted teeth were used (P < 0.05). In the current study, there was no significant difference in apical transportation between natural teeth prepared using WaveOne and those prepared using ProTaper Next. However, significant differences were observed between the two systems with resin blocks. These findings indicate that the use of resin blocks is not an accurate method for apical transportation evaluation.
NASA Astrophysics Data System (ADS)
Strohmaier, S. G.; Erbert, G.; Meissner-Schenk, A. H.; Lommel, M.; Schmidt, B.; Kaul, T.; Karow, M.; Crump, P.
2017-02-01
Progress will be presented on ongoing research into the development of ultra-high power and efficiency bars achieving significantly higher output power, conversion efficiency and brightness than currently commercially available. We combine advanced InAlGaAs/GaAs-based epitaxial structures and novel lateral designs, new materials and superior cooling architectures to enable improved performance. Specifically, we present progress in kilowatt-class 10-mm diode laser bars, where recent studies have demonstrated 880 W continuous wave output power from a 10 mm x 4 mm laser diode bar at 850 A of electrical current and 15°C water temperature. This laser achieves < 60% electro-optical efficiency at 880 W CW output power.
NASA Astrophysics Data System (ADS)
McQuiddy, David N., Jr.; Sokolov, Vladimir
1990-12-01
The present conference discusses microwave filters, lightwave technology for microwave antennas, planar and quasi-planar guides, mixers and VCOs, cavity filters, discontinuity and coupling effects, control circuits, power dividers and phase shifters, microwave ICs, biological effects and medical applications, CAD and modeling for MMICs, directional couplers, MMIC design trends, microwave packaging and manufacturing, monolithic ICs, and solid-state devices and circuits. Also discussed are microwave and mm-wave superconducting technology, MICs for communication systems, the merging of optical and microwave technologies, microwave power transistors, ferrite devices, network measurements, advanced transmission-line structures, FET devices and circuits, field theory of IC discontinuities, active quasi-optical techniques, phased-array techniques and circuits, nonlinear CAD, sub-mm wave devices, and high power devices.
Noponen, Eero; Tamminen, Aleksi; Vaaja, Matti
2007-07-10
A design formalism is presented for transmission-type phase holograms for use in a submillimeter-wave compact radar-cross-section (RCS) measurement range. The design method is based on rigorous electromagnetic grating theory combined with conventional hologram synthesis. Hologram structures consisting of a curved groove pattern on a 320 mmx280 mm Teflon plate are designed to transform an incoming spherical wave at 650 GHz into an output wave generating a 100 mm diameter planar field region (quiet zone) at a distance of 1 m. The reconstructed quiet-zone field is evaluated by a numerical simulation method. The uniformity of the quiet-zone field is further improved by reoptimizing the goal field. Measurement results are given for a test hologram fabricated on Teflon.
Photonic-Assisted mm-Wave and THz Wireless Transmission towards 100 Gbit/s Data Rate
NASA Astrophysics Data System (ADS)
Freire Hermelo, Maria; Chuenchom, Rattana; Rymanov, Vitaly; Kaiser, Thomas; Sheikh, Fawad; Czylwik, Andreas; Stöhr, Andreas
2017-09-01
This paper presents photonic-assisted 60 GHz mm-wave and 325 GHz system approaches that enable the transmission of spectral-efficient and high data rate signals over fiber and over air. First, we focus on generic channel characteristics within the mm-wave 60 GHz band and at the terahertz (THz) band around 325 GHz. Next, for generating the high data rate baseband signals, we present a technical solution for constructing an extreme bandwidth arbitrary waveform generator (AWG). We then report the development of a novel coherent photonic mixer (CPX) module for direct optic-to-RF conversion of extreme wideband optical signals, with a>5 dB higher conversion gain compared to conventional photodiodes. Finally, we experimentally demonstrate record spectral efficient wireless transmission for both bands. The achieved spectral efficiencies reach 10 bit/s/Hz for the 60 GHz band and 6 bit/s/Hz for the 325 GHz band. The maximum data rate transmitted at THz frequencies in the 325 GHz band is 59 Gbit/s using a 64-QAM-OFDM modulation format and a 10 GHz wide data signal.
SiGe BiCMOS manufacturing platform for mmWave applications
NASA Astrophysics Data System (ADS)
Kar-Roy, Arjun; Howard, David; Preisler, Edward; Racanelli, Marco; Chaudhry, Samir; Blaschke, Volker
2010-10-01
TowerJazz offers high volume manufacturable commercial SiGe BiCMOS technology platforms to address the mmWave market. In this paper, first, the SiGe BiCMOS process technology platforms such as SBC18 and SBC13 are described. These manufacturing platforms integrate 200 GHz fT/fMAX SiGe NPN with deep trench isolation into 0.18μm and 0.13μm node CMOS processes along with high density 5.6fF/μm2 stacked MIM capacitors, high value polysilicon resistors, high-Q metal resistors, lateral PNP transistors, and triple well isolation using deep n-well for mixed-signal integration, and, multiple varactors and compact high-Q inductors for RF needs. Second, design enablement tools that maximize performance and lowers costs and time to market such as scalable PSP and HICUM models, statistical and Xsigma models, reliability modeling tools, process control model tools, inductor toolbox and transmission line models are described. Finally, demonstrations in silicon for mmWave applications in the areas of optical networking, mobile broadband, phased array radar, collision avoidance radar and W-band imaging are listed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Der Agobian, R.
1964-10-31
The shock waves Droduced by condenser discharge in a gas tube were investigated. The study was limited to wave velocities less than five times the speed of sound, propagated in gas at low pressure (several mm Hg). A method was designed and perfected for the detection of the shock waves that are insufficiently rapid to produce gas ionization. This method consisted of the creation of an autonomous plasma, before the arrival of the wave, which was then modified by the wave passage. two methods were used for the detection of phenomena accompanying the passage of the shock waves, an opticalmore » method and a radioelectric method. The qualitative study of the modifications produced on the wave passage showed the remarkable correlation existing between the results obtained by the two methods. The experimental results on the propagation laws for shock waves in a low-diameter tube agreed with theory. The variations of the coefficient oi recombination were determined as a iunction of the electron temperature, and the results were in good agreement with the Bates theory. It was shown that the electron gas of the plasma had the same increase of density as a neutral gas during the passage of a shock wave. The variations of the frequency of electron collisions on passage of the shock wave could be explained by considering the electron--ion collisions with respect to electron-- atom collisions. (J.S.R.)« less
Shock wave attenuation in a micro-channel
NASA Astrophysics Data System (ADS)
Giordano, J.; Perrier, P.; Meister, L.; Brouillette, M.
2018-05-01
This work presents optical measurements of shock wave attenuation in a glass micro-channel. This transparent facility, with a cross section ranging from 1 mm× 150 μm to 1 mm× 500 μm, allowed for the use of high-speed schlieren videography to visualize the propagation of a shock wave within the entire micro-channel and to quantify velocity attenuation of the wave due to wall effects. In this paper, we present the experimental technique and the relevant data treatment we have used to increase the sensitivity of shock wave detection. Then, we compared our experimental results for different channel widths, lengths, and shock wave velocities with the analytical model for shock attenuation proposed by Russell (J Fluid Mech 27(2):305-314, 1967), which assumes laminar flow, and by Mirels (Attenuation in a shock tube due to unsteady-boundary-layer action, NACA Report 1333, 1957) for turbulent flow. We found that these models are inadequate to predict the observed data, owing to the presence of fully developed flow which violates the basic assumption of these models. The data are also compared with the empirical shock attenuation models proposed by Zeitoun (Phys Fluids 27(1):011701, 2015) and Deshpande and Puranik (Shock Waves 26(4):465-475, 2016), where better agreement is observed. Finally, we presented experimental data for the flow field behind the shock wave from measurements of the Mach wave angle which shows globally decreasing flow Mach numbers due to viscous wall effects.
Experimental investigation of electron guns for THz microwave vacuum amplifiers
NASA Astrophysics Data System (ADS)
Burtsev, A. A.; Grigor'ev, Yu. A.; Navrotsky, I. A.; Rogovin, V. I.; Sakhadzhi, G. V.; Shumikhin, K. V.
2016-05-01
Single-sheet and multiple beam electron emitters based on thermionic minicathodes for terahertz traveling-wave tubes have been studied. Data are presented for impregnated blade thermionic cathode with dimensions 0.1 × 0.7 mm and a maximum current density of 114 A/cm2 in a pulsed mode. A variant of the five-beam electron gun with 0.25-mm-diameter cylindrical minicathodes in cells of a control grid is proposed that provides a current density of 85.5 A/cm2 at a grid potential of 900-1000 V.
Harmonic generation of Lamb waves
NASA Astrophysics Data System (ADS)
Ing, Ros Kiri
2002-11-01
Lamb waves are dispersive waves that propagate following a number of distinct modes that depend on the values of the central frequency and frequency band. According to such properties and using the time-reversal process, it is shown that the hyperfocusing effect may be experienced [R. K. Ing and M. Fink, IEEE Trans. Ultrason. Ferroelectr. Freq. Control 45, 1032-1043 (1998)]. Such a focusing effect both relates the time recompression of the dispersive Lamb waves and constructive interference on the focus point of the modes involved. The hyperfocusing effect is interesting because it allows the amplitude of the Lamb waves to reach huge values on the focus point. In our experiments, Lamb waves with normal amplitudes of micrometer values have been achieved on the free surface of a Duralumin plate of 3 mm thickness. By analyzing the Lamb waves in the neighborhood of the focus point using the 2-D Fourier transform technique, a nonlinear process of harmonic generation is then observed--the fundamental frequency component is centered at 1.5 MHz. This nonlinear process is under study and quantified.
NASA Astrophysics Data System (ADS)
Ambroziński, Łukasz; Pelivanov, Ivan; Song, Shaozhen; Yoon, Soon Joon; Li, David; Gao, Liang; Shen, Tueng T.; Wang, Ruikang K.; O'Donnell, Matthew
2016-07-01
A non-contact method for efficient, non-invasive excitation of mechanical waves in soft media is proposed, in which we focus an ultrasound (US) signal through air onto the surface of a medium under study. The US wave reflected from the air/medium interface provides radiation force to the medium surface that launches a transient mechanical wave in the transverse (lateral) direction. The type of mechanical wave is determined by boundary conditions. To prove this concept, a home-made 1 MHz piezo-ceramic transducer with a matching layer to air sends a chirped US signal centered at 1 MHz to a 1.6 mm thick gelatin phantom mimicking soft biological tissue. A phase-sensitive (PhS)-optical coherence tomography system is used to track/image the mechanical wave. The reconstructed transient displacement of the mechanical wave in space and time demonstrates highly efficient generation, thus offering great promise for non-contact, non-invasive characterization of soft media, in general, and for elasticity measurements in delicate soft tissues and organs in bio-medicine, in particular.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ambroziński, Łukasz; AGH University of Science and Technology, Krakow 30059; Pelivanov, Ivan, E-mail: ivanp3@uw.edu
A non-contact method for efficient, non-invasive excitation of mechanical waves in soft media is proposed, in which we focus an ultrasound (US) signal through air onto the surface of a medium under study. The US wave reflected from the air/medium interface provides radiation force to the medium surface that launches a transient mechanical wave in the transverse (lateral) direction. The type of mechanical wave is determined by boundary conditions. To prove this concept, a home-made 1 MHz piezo-ceramic transducer with a matching layer to air sends a chirped US signal centered at 1 MHz to a 1.6 mm thick gelatin phantom mimicking softmore » biological tissue. A phase-sensitive (PhS)-optical coherence tomography system is used to track/image the mechanical wave. The reconstructed transient displacement of the mechanical wave in space and time demonstrates highly efficient generation, thus offering great promise for non-contact, non-invasive characterization of soft media, in general, and for elasticity measurements in delicate soft tissues and organs in bio-medicine, in particular.« less
Electrocardiographic patterns in African University strength and endurance athletes of Zulu descent.
Grace, J; Duvenage, E; Jordaan, J P
2015-11-01
There is concern over the effect of training on heart function of athletes as recorded by 12-lead electrocardiography (ECG). Although ECG abnormalities with respect to ethnic origin of black athletes from the Caribbean, West Africa and East Africa have been reported, black athletes from southern Africa, specifically participating in different sports, have never been investigated before. The purpose of this study was to analyze the ECG patterns in South African students of Zulu descent, who represented our university in boxing (endurance modality) and body building (resistance modality) at a regional level. Fifteen subjects each were assigned to an endurance (E), resistance (R) or control (C) group, respectively. ECG patterns were recorded with a 12-lead ECG. Our subjects indicated no significant differences in ECG patterns in relation to whether they participate in strength or endurance related sport. However, 80% of the endurance group and 67% of the resistance displayed ECG criteria indicative of left ventricular hypertrophy (LVH), group E displays higher R5/S1-wave voltages (E=43.3 mm; R=36.8 mm; C=37.1 mm) as well distinctly abnormal ECG patterns (E=87%; R=73%; C=53%), raising clinical suspicion of structural heart disease. Our cohort presented with non-significant, marked ST-segment elevation (53% of both the E and R groups) and inverted T-waves in 27% of the E group. Similar to findings in other ethnic Africans, a large proportion of our Zulu study population displayed ECG criteria indicative of LVH on the evidence of a marked increase of R5/S1-wave voltage and ST/T-segment changes with no differences in relation to whether they participate in strength or endurance related sport.
NASA Astrophysics Data System (ADS)
Savin, A.; Novy, F.; Fintova, S.; Steigmann, R.
2017-08-01
The current stage of nondestructive evaluation techniques imposes the development of new electromagnetic (EM) methods that are based on high spatial resolution and increased sensitivity. In order to achieve high performance, the work frequencies must be either radifrequencies or microwaves. At these frequencies, at the dielectric/conductor interface, plasmon polaritons can appear, propagating between conductive regions as evanescent waves. In order to use the evanescent wave that can appear even if the slits width is much smaller that the wavwelength of incident EM wave, a sensor with metamaterial (MM) is used. The study of the EM field diffraction against the edge of long thin discontinuity placed under the inspected surface of a conductive plate has been performed using the geometrical optics principles. This type of sensor having the reception coils shielded by a conductive screen with a circular aperture placed in the front of reception coil of emission reception sensor has been developed and “transported” information for obtaining of magnified image of the conductive structures inspected. This work presents a sensor, using MM conical Swiss roll type that allows the propagation of evanescent waves and the electromagnetic images are magnified. The test method can be successfully applied in a variety of applications of maxim importance such as defect/damage detection in materials used in automotive and aviation technologies. Applying this testing method, spatial resolution can be improved.
Grassi, Davide; Draijer, Richard; Desideri, Giovambattista; Mulder, Theo; Ferri, Claudio
2015-01-01
Hypertension and arterial stiffening are independent predictors of cardiovascular mortality. Flavonoids may exert some vascular protection. We investigated the effects of black tea on blood pressure (BP) and wave reflections before and after fat load in hypertensives. According to a randomized, double-blind, controlled, cross-over design, 19 patients were assigned to consume black tea (129 mg flavonoids) or placebo twice a day for eight days (13 day wash-out period). Digital volume pulse and BP were measured before and 1, 2, 3 and 4 h after tea consumption. Measurements were performed in a fasted state and after a fat load. Compared to placebo, reflection index and stiffness index decreased after tea consumption (p < 0.0001). Fat challenge increased wave reflection, which was counteracted by tea consumption (p < 0.0001). Black tea decreased systolic and diastolic BP (−3.2 mmHg, p < 0.005 and −2.6 mmHg, p < 0.0001; respectively) and prevented BP increase after a fat load (p < 0.0001). Black tea consumption lowers wave reflections and BP in the fasting state, and during the challenging haemodynamic conditions after a fat load in hypertensives. Considering lipemia-induced impairment of arterial function may occur frequently during the day, our findings suggest regular consumption of black tea may be relevant for cardiovascular protection. PMID:25658240
Development of a technique for determination of pulmonary artery pulse wave velocity in horses.
Silva, Gonçalo Teixeira de Almeida; Guest, Bruce B; Gomez, Diego E; McGregor, Martine; Viel, Laurent; O'Sullivan, M Lynne; Runciman, John; Arroyo, Luis G
2017-05-01
Calcification of the tunica media of the axial pulmonary arteries (PA) has been reported in a large proportion of racehorses. In humans, medial calcification is a significant cause of arterial stiffening and is implicated in the pathogenesis of cardiac, cerebral, and renal microvascular diseases. Pulse wave velocity (PWV) provides a measure of arterial stiffness. This study aimed to develop a technique to determine PA-PWV in horses and, secondarily, to investigate a potential association between PA-PWV and arterial fibro-calcification. A dual-pressure sensor catheter (PSC) was placed in the main PA of 10 sedated horses. The pressure waves were used to determine PWV along the PA, using the statistical phase offset method. Histological analysis of the PA was performed to investigate the presence of fibro-calcified lesions. The mean (±SD) PWV was 2.3 ± 0.7 m/s in the proximal PA trunk and 1.1 ± 0.1 m/s further distal (15 cm) in a main PA branch. The mean (±SD) of mean arterial pressures in the proximal PA trunk was 30.1 ± 5.2 mmHg, and 22.0 ± 6.0 mmHg further distal (15 cm) within the main PA branch. The mean (±SD) pulse pressure in the proximal PA trunk was 15.0 ± 4.7 mmHg, and 13.5 ± 3.3 mmHg further distal (15 cm) within the main PA branch. Moderate to severe lesions of the tunica media of the PAs were observed in seven horses, but a correlation with PWV could not be established yet. Pulmonary artery PWV may be determined in standing horses. The technique described may allow further investigation of the effect of calcification of large PAs in the pathogenesis of equine pulmonary circulatory disorders. NEW & NOTEWORTHY Pulmonary artery pulse wave velocity was determined safely in standing sedated horses. The technique described may allow further investigation of the effect of calcification of large pulmonary arteries in the pathogenesis of pulmonary circulatory disorders in horses. Copyright © 2017 the American Physiological Society.
Analysis of Ground Motion from An Underground Chemical Explosion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pitarka, Arben; Mellors, Robert J.; Walter, William R.
Here in this paper we investigate the excitation and propagation of far-field seismic waves from the 905 kg trinitrotoluene equivalent underground chemical explosion SPE-3 recorded during the Source Physics Experiment (SPE) at the Nevada National Security Site. The recorded far-field ground motion at short and long distances is characterized by substantial shear-wave energy, and large azimuthal variations in P-and S-wave amplitudes. The shear waves observed on the transverse component of sensors at epicentral distances <50 m suggests they were generated at or very near the source. The relative amplitude of the shear waves grows as the waves propagate away frommore » the source. We analyze and model the shear-wave excitation during the explosion in the 0.01–10 Hz frequency range, at epicentral distances of up to 1 km. We used two simulation techniques. One is based on the empirical isotropic Mueller–Murphy (MM) (Mueller and Murphy, 1971) nuclear explosion source model, and 3D anelastic wave propagation modeling. The second uses a physics-based approach that couples hydrodynamic modeling of the chemical explosion source with anelastic wave propagation modeling. Comparisons with recorded data show the MM source model overestimates the SPE-3 far-field ground motion by an average factor of 4. The observations show that shear waves with substantial high-frequency energy were generated at the source. However, to match the observations additional shear waves from scattering, including surface topography, and heterogeneous shallow structure contributed to the amplification of far-field shear motion. Comparisons between empirically based isotropic and physics-based anisotropic source models suggest that both wave-scattering effects and near-field nonlinear effects are needed to explain the amplitude and irregular radiation pattern of shear motion observed during the SPE-3 explosion.« less
Analysis of Ground Motion from An Underground Chemical Explosion
Pitarka, Arben; Mellors, Robert J.; Walter, William R.; ...
2015-09-08
Here in this paper we investigate the excitation and propagation of far-field seismic waves from the 905 kg trinitrotoluene equivalent underground chemical explosion SPE-3 recorded during the Source Physics Experiment (SPE) at the Nevada National Security Site. The recorded far-field ground motion at short and long distances is characterized by substantial shear-wave energy, and large azimuthal variations in P-and S-wave amplitudes. The shear waves observed on the transverse component of sensors at epicentral distances <50 m suggests they were generated at or very near the source. The relative amplitude of the shear waves grows as the waves propagate away frommore » the source. We analyze and model the shear-wave excitation during the explosion in the 0.01–10 Hz frequency range, at epicentral distances of up to 1 km. We used two simulation techniques. One is based on the empirical isotropic Mueller–Murphy (MM) (Mueller and Murphy, 1971) nuclear explosion source model, and 3D anelastic wave propagation modeling. The second uses a physics-based approach that couples hydrodynamic modeling of the chemical explosion source with anelastic wave propagation modeling. Comparisons with recorded data show the MM source model overestimates the SPE-3 far-field ground motion by an average factor of 4. The observations show that shear waves with substantial high-frequency energy were generated at the source. However, to match the observations additional shear waves from scattering, including surface topography, and heterogeneous shallow structure contributed to the amplification of far-field shear motion. Comparisons between empirically based isotropic and physics-based anisotropic source models suggest that both wave-scattering effects and near-field nonlinear effects are needed to explain the amplitude and irregular radiation pattern of shear motion observed during the SPE-3 explosion.« less
NASA Astrophysics Data System (ADS)
Li, Chunhui; Guan, Guangying; Huang, Zhihong; Wang, Ruikang K.; Nabi, Ghulam
2015-03-01
By combining with the phase sensitive optical coherence tomography (PhS-OCT), vibration and surface acoustic wave (SAW) methods have been reported to provide elastography of skin tissue respectively. However, neither of these two methods can provide the elastography in full skin depth in current systems. This paper presents a feasibility study on an optical coherence elastography method which combines both vibration and SAW in order to give the quantitative mechanical properties of skin tissue with full depth range, including epidermis, dermis and subcutaneous fat. Experiments are carried out on layered tissue mimicking phantoms and in vivo human forearm and palm skin. A ring actuator generates vibration while a line actuator were used to excited SAWs. A PhS-OCT system is employed to provide the ultrahigh sensitive measurement of the generated waves. The experimental results demonstrate that by the combination of vibration and SAW method the full skin bulk mechanical properties can be quantitatively measured and further the elastography can be obtained with a sensing depth from ~0mm to ~4mm. This method is promising to apply in clinics where the quantitative elasticity of localized skin diseases is needed to aid the diagnosis and treatment.
On the Piezoelectric Detection of Guided Ultrasonic Waves
2017-01-01
In order to quantify the wave motion of guided ultrasonic waves, the characteristics of piezoelectric detectors, or ultrasonic transducers and acoustic emission sensors, have been evaluated systematically. Such guided waves are widely used in structural health monitoring and nondestructive evaluation, but methods of calibrating piezoelectric detectors have been inadequate. This study relied on laser interferometry for the base displacement measurement of bar waves, from which eight different guided wave test set-ups are developed with known wave motion using piezoelectric transmitters. Both plates and bars of 12.7 and 6.4 mm thickness were used as wave propagation media. The upper frequency limit was 2 MHz. Output of guided wave detectors were obtained on the test set-ups and their receiving sensitivities were characterized and averaged. While each sensitivity spectrum was noisy for a detector, the averaged spectrum showed a good convergence to a unique receiving sensitivity. Twelve detectors were evaluated and their sensitivity spectra determined in absolute units. Generally, these showed rapidly dropping sensitivity with increasing frequency due to waveform cancellation on their sensing areas. This effect contributed to vastly different sensitivities to guided wave and to normally incident wave for each one of the 12 detectors tested. Various other effects are discussed and recommendations on methods of implementing the approach developed are provided. PMID:29156579
Impact of boat generated waves over an estuarine intertidal zone of the Seine estuary (France)
NASA Astrophysics Data System (ADS)
Deloffre, Julien; Lafite, Robert
2015-04-01
Water movements in macrotidal estuaries are controlled by the tidal regime modulated seasonally by the fluvial discharge. Wind effect on hydrodynamics and sediment transport is also reported at the mouth. Besides estuaries are frequently man altered our knowledge on the human impact on hydrodynamics and sediment transport is less extended. As an example on the Seine estuary (France) port authorities have put emphasis on facilitating economic exchanges by means of embankment building and increased dredging activity over the last century. These developments led to secure sea vessel traffic in the Seine estuary but they also resulted in a change of estuarine hydrodynamics and sediment transport features. Consequences of boat generated waves are varied: increased water turbidity and sediment transfer, release of nutrient and contaminants in the water column, harmful to users, ecosystems and infrastructures generating important maintenance spending. The aim of this study is to analyse the impact of boat generated waves on sediment transport over an intertidal area. The studied site is located on the left bank in the fluvial part of the Seine estuary. On this site the maximum tidal range ranges between 1.25 and 3.5m respectively during neap and spring tide. The sampling strategy is based on continuous ADV acquisition at 4Hz coupled with turbidimeter and altimeter measurements (1 measurement every minute) in order to decipher sediment dynamics during one year. Our results indicate that sediment dynamics are controlled by river flow while medium term scale evolution is dependent on tidal range and short term dynamics on sea-vessels waves. 64% of boat passages generated significant sediment reworking (from few mm.min-1 to 3cm.min-1). This reworking rate is mainly controlled by two parameters: (i) water height on the site and (ii) vessels characteristics; in particular the distance between seabed and keel that generate a Bernoulli wave (with maximum amplitude of 0.6m). Simultaneous hydrodynamics and bed elevation measurements permit to quantify the impact of the boat generated wave. Measurements demonstrate that the sediment transport occurs during the Bernoulli wave (few mm up to 8cm). This mechanism induces mainly a long-shore transfer of particles over the interdal area. This study proves that the sediment transport generated by boat waves cannot be neglected in the Seine estuary case.
Internal Waves, South China Sea
1983-06-24
STS007-05-245 (18-24 June 1983) --- A rare view of internal waves in the South China Sea. Several different series of internal waves are represented in the 70mm frame, exposed with a handheld camera by members of the STS-7 astronaut crew aboard the Earth-orbiting Challenger. The land area visible in the lower left is part of the large island of Hainan, China.
Comparative study of high power Tm:YLF and Tm:LLF slab lasers in continuous wave regime.
Berrou, Antoine; Collett, Oliver J P; Morris, Daniel; Esser, M J Daniel
2018-04-16
We report on Tm:YLF and Tm:LLF slab lasers (1.5 x 11 x 20 mm 3 ) end pumped from one end with a high-brightness 792 nm laser diode stack. These two lasers are compared under identical pump conditions in continuous-wave regime. A stronger negative thermal lens in Tm:LLF than in Tm:YLF is highlighted, making it more difficult to operate the Tm:LLF laser under stable lasing conditions. In a configuration where the high reflectivity cavity mirror has a radius of curvature of r = 150 mm, the Tm:YLF (Tm:LLF) laser produces a maximum output power of 150 W (143 W) for 428 W of incident pump power (respectively). For a second cavity configuration where the high reflectivity cavity mirror has a radius of curvature of r = 500 mm, the Tm:YLF laser produces a maximum output power of 164 W for 412 W of incident pump power and a 57% slope efficiency with respect to the absorbed pump power. The emitted wavelength of these two lasers are measured as a function of the output coupler reflectivity and it shows that Tm:LLF laser emits at a longer wavelength than Tm:YLF.
He, Cunfu; Yan, Lyu; Zhang, Haijun
2018-01-01
It is necessary to develop a transducer that can quickly detect the inner and outer wall defects of thick-walled pipes, in order to ensure the safety of such pipes. In this paper, a flexible broadband Rayleigh-waves comb transducer based on PZT (lead zirconate titanate) for defect detection of thick-walled pipes is studied. The multiple resonant coupling theory is used to expand the transducer broadband and the FEA (Finite Element Analysis) method is used to optimize transducer array element parameters. Optimization results show that the best array element parameters of the transducer are when the transducer array element length is 30 mm, the thickness is 1.2 mm, the width of one end of is 1.5 mm, and the other end is 3 mm. Based on the optimization results, such a transducer was fabricated and its performance was tested. The test results were consistent with the finite-element simulation results, and the −3 dB bandwidth of the transducer reached 417 kHz. Transducer directivity test results show that the Θ−3dB beam width was equal to 10 °, to meet the defect detection requirements. Finally, defects of thick-walled pipes were detected using the transducer. The results showed that the transducer could detect the inner and outer wall defects of thick-walled pipes within the bandwidth. PMID:29498636
Zhao, Huamin; He, Cunfu; Yan, Lyu; Zhang, Haijun
2018-03-02
It is necessary to develop a transducer that can quickly detect the inner and outer wall defects of thick-walled pipes, in order to ensure the safety of such pipes. In this paper, a flexible broadband Rayleigh-waves comb transducer based on PZT (lead zirconate titanate) for defect detection of thick-walled pipes is studied. The multiple resonant coupling theory is used to expand the transducer broadband and the FEA (Finite Element Analysis) method is used to optimize transducer array element parameters. Optimization results show that the best array element parameters of the transducer are when the transducer array element length is 30 mm, the thickness is 1.2 mm, the width of one end of is 1.5 mm, and the other end is 3 mm. Based on the optimization results, such a transducer was fabricated and its performance was tested. The test results were consistent with the finite-element simulation results, and the -3 dB bandwidth of the transducer reached 417 kHz. Transducer directivity test results show that the Θ -3dB beam width was equal to 10 °, to meet the defect detection requirements. Finally, defects of thick-walled pipes were detected using the transducer. The results showed that the transducer could detect the inner and outer wall defects of thick-walled pipes within the bandwidth.
Guided wave tomography in anisotropic media using recursive extrapolation operators
NASA Astrophysics Data System (ADS)
Volker, Arno
2018-04-01
Guided wave tomography is an advanced technology for quantitative wall thickness mapping to image wall loss due to corrosion or erosion. An inversion approach is used to match the measured phase (time) at a specific frequency to a model. The accuracy of the model determines the sizing accuracy. Particularly for seam welded pipes there is a measurable amount of anisotropy. Moreover, for small defects a ray-tracing based modelling approach is no longer accurate. Both issues are solved by applying a recursive wave field extrapolation operator assuming vertical transverse anisotropy. The inversion scheme is extended by not only estimating the wall loss profile but also the anisotropy, local material changes and transducer ring alignment errors. This makes the approach more robust. The approach will be demonstrated experimentally on different defect sizes, and a comparison will be made between this new approach and an isotropic ray-tracing approach. An example is given in Fig. 1 for a 75 mm wide, 5 mm deep defect. The wave field extrapolation based tomography clearly provides superior results.
NASA Technical Reports Server (NTRS)
Dezafra, R. L.; Mallison, W. H.; Jaramillo, M.; Reeves, J. M.; Emmons, L. K.; Shindell, D. T.
1994-01-01
We describe a recently constructed ground-based mm-wave spectrometer incorporating a superconducting tunnel junction as a heterodyne mixer-receiver. Under conditions of low tropospheric water vapor, the superior sensitivity of this receiver allows spectral line measurements of stratospheric molecules with mixing ratios as small as a few tenths of a part per billion (e.g., ClO, HCN) to be made in 4 to 6 hours, with a signal to noise ratio of at least 30:1. We expect to be able to halve this time by further improvement of the mixer's intrinsic noise level.
Arthritis inflammation monitored by subcutaneous millimeter wave thermography.
Edrich, J; Smyth, C J
1978-01-01
A new technique for remote, noninvasive mapping of temperature elevations of the human joints is described; it uses the mm wave radiation emitted by the human body. A solid state switched scanner for 68 GHz is described which overcomes the depth limitations of conventional, infrared thermographs and can measure to subcutaneous depths of several mm with a temperature resolution of 0.25 degrees C. Measurements on rheumatoid arthritic knee joints are presented which show little correlation with simultaneously measured skin temperatures. Significant longterm thermographic changes induced by steroid injection indicate a potential for objective patient monitoring and development of new treatment methods.
Advanced accelerator and mm-wave structure research at LANL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simakov, Evgenya Ivanovna
2016-06-22
This document outlines acceleration projects and mm-wave structure research performed at LANL. The motivation for PBG research is described first, with reference to couplers for superconducting accelerators and structures for room-temperature accelerators and W-band TWTs. These topics are then taken up in greater detail: PBG structures and the MIT PBG accelerator; SRF PBG cavities at LANL; X-band PBG cavities at LANL; and W-band PBG TWT at LANL. The presentation concludes by describing other advanced accelerator projects: beam shaping with an Emittance Exchanger, diamond field emitter array cathodes, and additive manufacturing of novel accelerator structures.
Long-Term Global Morphology of Gravity Wave Activity Using UARS Data
NASA Technical Reports Server (NTRS)
Eckermann, Stephen D.; Jackman, C. (Technical Monitor)
2000-01-01
Gravity waves in satellite data from CRISTA and MLS are studied in depth this quarter. Results this quarter are somewhat limited due to the PI'S heavy involvement throughout this reporting period in on-site forecasting of mountain wave-induced turbulence for the NASA's ER-2 research aircraft at Kiruna, Sweden during the SAGE Ill Ozone Loss and Validation Experiment (SOLVE). Results reported concentrate on further mesoscale modeling studies of mountain waves over the southern Andes, evident in CRISTA and MLS data. Two-dimensional mesoscale model simulations are extended through generalization of model equations to include both rotation and a first-order turbulence closure scheme. Results of three experiments are analyzed in depth and submitted for publication. We also commence simulations with a three-dimensional mesoscale model (MM5) and present preliminary results for the CRISTA 1 period near southern South America. Combination of ground-based temperature data at 87 km from two sites with global HRDl data was continued this quarter, showing stationary planetary wave structures. This work was also submitted for publication.
Muth, Bryce J; Brian, Michael S; Chirinos, Julio A; Lennon, Shannon L; Farquhar, William B; Edwards, David G
2017-10-01
High dietary sodium intake can lead to hypertension and increased incidence of cardiovascular disease. We sought to determine the effect of short-term dietary sodium loading on central blood pressure and arterial stiffness in young (YG; 22-40 years) and middle-aged (MA; 41-60 years) normotensive adults. YG (n = 49; age: 27 ± 1 years) and MA (n = 36; age: 52 ± 1 years) subjects were randomized, in a cross-over design, to 7 days of low-sodium (LS; 20 mmol/d) or high-sodium (HS; 300 mmol/d) diet. On the last day of each diet, central pressures, forward and reflected wave amplitudes (via radial artery applanation tonometry), and carotid-femoral pulse wave velocity were assessed. Central systolic blood pressure (cSBP) was greater after HS in both YG (LS: 96 ± 1 vs. HS: 99 ± 1 mm Hg; P = .012) and MA (LS: 106 ± 2 vs. HS: 115 ± 3 mm Hg; P < .001). However, the increase in cSBP was greater in MA (YG: 4 ± 1 vs. MA: 9 ± 2; P = .02). In MA subjects, HS elicited greater forward (LS: 25 ± 1 vs. HS: 29 ± 1 mm Hg; P < .001) and reflected (LS: 19 ± 1 vs. HS: 23 ± 1 mm Hg; P < .001) wave amplitudes. Carotid-femoral pulse wave velocity was also greater in MA on HS but after adjustment for mean arterial pressure, the difference was no longer significant. Our data indicate that HS intake leads to a greater increase in cSBP in MA adults, which may be the result of increased forward and reflected wave amplitudes. Copyright © 2017 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.
Zhang, Xiongliang; Yan, Xiaoyu; Wang, Chunyang; Tang, Tingting; Chai, Yimin
2014-01-01
Extracorporeal shock wave therapy (ESWT) has been demonstrated to have the angiogenic effect on ischemic tissue. We hypothesize that ESWT exerts the proangiogenesis effect with an energy density-dependent mode on the target cells. Endothelial progenitor cells (EPCs) of rats were obtained by cultivation of bone marrow-derived mononuclear cells. EPCs were divided into five groups of different energy densities, and each group was furthermore subdivided into four groups of different shock numbers. Thus, there were 20 subgroups in total. The expressions of angiogenic factors, apoptotic factors, inflammation mediators, and chemotactic factors were examined, and the proliferation activity was measured after ESWT. When EPCs were treated with low-energy (0.04-0.13 mJ/mm(2)) shock wave, the expressions of endothelial nitric oxide synthase, angiopoietin (Ang) 1, Ang-2, and B-cell lymphoma 2 increased and those of interleukin 6, fibroblast growth factor 2, C-X-C chemokine receptor type 4, vascular endothelial growth factor a, Bcl-2-associated X protein, and caspase 3 decreased. stromal cell-derived factor 1 changed without statistical significance. When cells were treated with high-energy (0.16 mJ/mm(2)) shock wave, most of the expressions of cytokines declined except the apoptotic factors and fibroblast growth factor 2, and cells lead to apoptosis. The proliferation activity and the ratio of Ang-1/Ang-2 reached their peak values, when cells were treated with ESWT with the intensity ranging from 0.10-0.13 mJ/mm(2) and shock number ranging from 200-300 impulses. Meanwhile, a minimal value of the ratio of Bax/Bcl-2 was observed. There is a dose-effect relationship in ESWT. The shock intensity ranging from 0.10-0.13 mJ/mm(2) and shock number ranging from 200-300 impulses were the optimal parameters for ESWT to treat cells in vitro. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.
Use of an Atrial Lead with Very Short Tip-To-Ring Spacing Avoids Oversensing of Far-Field R-Wave
Kolb, Christof; Nölker, Georg; Lennerz, Carsten; Jetter, Hansmartin; Semmler, Verena; Pürner, Klaus; Gutleben, Klaus-Jürgen; Reents, Tilko; Lang, Klaus; Lotze, Ulrich
2012-01-01
Objective The AVOID-FFS (Avoidance of Far-Field R-wave Sensing) study aimed to investigate whether an atrial lead with a very short tip-to-ring spacing without optimization of pacemaker settings shows equally low incidence of far-field R-wave sensing (FFS) when compared to a conventional atrial lead in combination with optimization of the programming. Methods Patients receiving a dual chamber pacemaker were randomly assigned to receive an atrial lead with a tip-to-ring spacing of 1.1 mm or a lead with a conventional tip-to-ring spacing of 10 mm. Postventricular atrial blanking (PVAB) was programmed to the shortest possible value of 60 ms in the study group, and to an individually determined optimized value in the control group. Atrial sensing threshold was programmed to 0.3 mV in both groups. False positive mode switch caused by FFS was evaluated at one and three months post implantation. Results A total of 204 patients (121 male; age 73±10 years) were included in the study. False positive mode switch caused by FFS was detected in one (1%) patient of the study group and two (2%) patients of the control group (p = 0.62). Conclusion The use of an atrial electrode with a very short tip-to-ring spacing avoids inappropriate mode switch caused by FFS without the need for individual PVAB optimization. Trial Registration ClinicalTrials.gov NCT00512915 PMID:22745661
Use of an atrial lead with very short tip-to-ring spacing avoids oversensing of far-field R-wave.
Kolb, Christof; Nölker, Georg; Lennerz, Carsten; Jetter, Hansmartin; Semmler, Verena; Pürner, Klaus; Gutleben, Klaus-Jürgen; Reents, Tilko; Lang, Klaus; Lotze, Ulrich
2012-01-01
The AVOID-FFS (Avoidance of Far-Field R-wave Sensing) study aimed to investigate whether an atrial lead with a very short tip-to-ring spacing without optimization of pacemaker settings shows equally low incidence of far-field R-wave sensing (FFS) when compared to a conventional atrial lead in combination with optimization of the programming. Patients receiving a dual chamber pacemaker were randomly assigned to receive an atrial lead with a tip-to-ring spacing of 1.1 mm or a lead with a conventional tip-to-ring spacing of 10 mm. Postventricular atrial blanking (PVAB) was programmed to the shortest possible value of 60 ms in the study group, and to an individually determined optimized value in the control group. Atrial sensing threshold was programmed to 0.3 mV in both groups. False positive mode switch caused by FFS was evaluated at one and three months post implantation. A total of 204 patients (121 male; age 73±10 years) were included in the study. False positive mode switch caused by FFS was detected in one (1%) patient of the study group and two (2%) patients of the control group (p = 0.62). The use of an atrial electrode with a very short tip-to-ring spacing avoids inappropriate mode switch caused by FFS without the need for individual PVAB optimization. ClinicalTrials.gov NCT00512915.
Breast Microcalcification Detection Using Super-Resolution Ultrasound Image Reconstruction
2010-09-01
microcalcifications often occur as one of two types: calcium oxalate dihydrate or calcium hydroxyapatite. Their sizes range approximately from 0.1 mm to 0.5 mm...super-resolution imaging, ultrasound imaging, wave equation. 1. INTRODUCTION Microcalcifications, tiny specks of mineral deposits ( calcium ), are the
Passive millimeter wave simulation in blender
NASA Astrophysics Data System (ADS)
Murakowski, Maciej
Imaging in the millimeter wave (mmW) frequency range is being explored for applications where visible or infrared (IR) imaging fails, such as through atmospheric obscurants. However, mmW imaging is still in its infancy and imager systems are still bulky, expensive, and fragile, so experiments on imaging in real-world scenarios are difficult or impossible to perform. Therefore, a simulation system capable of predicting mmW phenomenology would be valuable in determining the requirements (e.g. resolution or noise floor) of an imaging system for a particular scenario and aid in the design of such an imager. Producing simulation software for this purpose is the objective of the work described in this thesis. The 3D software package Blender was modified to simulate the images produced by a passive mmW imager, based on a Geometrical Optics approach. Simulated imagery was validated against experimental data and the software was applied to novel imaging scenarios. Additionally, a database of material properties for use in the simulation was collected.
NASA Astrophysics Data System (ADS)
Kozuka, Teruyuki; Yasui, Kyuichi; Tuziuti, Toru; Towata, Atsuya; Lee, Judy; Iida, Yasuo
2009-07-01
Using a standing-wave field generated between a sound source and a reflector, it is possible to trap small objects at nodes of the sound pressure distribution in air. In this study, a sound field generated under a flat or concave reflector was studied by both experimental measurement and numerical calculation. The calculated result agrees well with the experimental data. The maximum force generated between a sound source of 25.0 mm diameter and a concave reflector is 0.8 mN in the experiment. A steel ball of 2.0 mm in diameter was levitated in the sound field in air.
Michaud, Mark; Leong, Thomas; Swiergon, Piotr; Juliano, Pablo; Knoerzer, Kai
2015-09-01
This work validated, in a higher frequency range, the theoretical predictions made by Boyle around 1930, which state that the optimal transmission of sound pressure through a metal plate occurs when the plate thickness equals a multiple of half the wavelength of the sound wave. Several reactor design parameters influencing the transmission of high frequency ultrasonic waves through a stainless steel plate were examined. The transmission properties of steel plates of various thicknesses (1-7 mm) were studied for frequencies ranging from 400 kHz to 2 MHz and at different distances between plates and transducers. It was shown that transmission of sound pressure through a steel plate showed high dependence of the thickness of the plate to the frequency of the sound wave (thickness ratio). Maximum sound pressure transmission of ∼ 60% of the incident pressure was observed when the ratio of the plate thickness to the applied frequency was a multiple of a half wavelength (2 MHz, 6mm stainless steel plate). In contrast, minimal sound pressure transmission (∼ 10-20%) was measured for thickness ratios that were not a multiple of a half wavelength. Furthermore, the attenuation of the sound pressure in the transmission region was also investigated. As expected, it was confirmed that higher frequencies have more pronounced sound pressure attenuation than lower frequencies. The spatial distribution of the sound pressure transmitted through the plate characterized by sonochemiluminescence measurements using luminol emission, supports the validity of the pressure measurements in this study. Copyright © 2015 Elsevier B.V. All rights reserved.
Manjunatha, B M; David, C G; Pratap, N; Al-Bulushi, Samir; Hago, B E
2012-06-01
The present study was carried out to elucidate the effect of progesterone (P4) from the induced corpus luteum (CL) on the characteristics of the dominant follicle (DF) in dromedary camels (Camelus dromedarius). Ovarian follicular and induced CL dynamics were monitored by transrectal ultrasonography in eight camels during the peak breeding season. The characteristics of the DF were monitored daily from the day of emergence into a wave, until it appeared to lose its dominance and the DF of a subsequent wave grew to a diameter of 13-17 mm. At this stage ovulation was induced by hCG and the DF was monitored every 8 h for 48 h. After ovulation, CL dynamics and follicular development (emergence of a new wave, growth and mature phase of the selected DF) were monitored daily. Blood samples were collected during each ultrasound examination to study the P4 profile in these animals. The CL developed to a maximum size (22.55 ± 3.24 mm) with a peak concentration of P4 (4.60 ± 2.57 ng/ml) 7 days after ovulation. The size of the CL was positively correlated with the P4 concentration (r = 0.612) during the different stages of the CL dynamics. The presence of CL did not affect the linear growth rate, duration of growth and mature phases of the DF. The development of the DF to its maximum size during its mature phase and inter-wave interval were not affected by the P4 secreted by the induced CL. In conclusion, there is no evidence from this study to suggest that P4 from induced CL altered the characteristics of a DF in dromedary camels. Copyright © 2012 Elsevier B.V. All rights reserved.
Domeier, Timothy L; Maxwell, Joshua T; Blatter, Lothar A
2012-01-01
β-Adrenergic signalling induces positive inotropic effects on the heart that associate with pro-arrhythmic spontaneous Ca2+ waves. A threshold level of sarcoplasmic reticulum (SR) Ca2+ ([Ca2+]SR) is necessary to trigger Ca2+ waves, and whether the increased incidence of Ca2+ waves during β-adrenergic stimulation is due to an alteration in this threshold remains controversial. Using the low-affinity Ca2+ indicator fluo-5N entrapped within the SR of rabbit ventricular myocytes, we addressed this controversy by directly monitoring [Ca2+]SR and Ca2+ waves during β-adrenergic stimulation. Electrical pacing in elevated extracellular Ca2+ ([Ca2+]o= 7 mm) was used to increase [Ca2+]SR to the threshold where Ca2+ waves were consistently observed. The β-adrenergic agonist isoproterenol (ISO; 1 μm) increased [Ca2+]SR well above the control threshold and consistently triggered Ca2+ waves. However, when [Ca2+]SR was subsequently lowered in the presence of ISO (by lowering [Ca2+]o to 1 mm and partially inhibiting sarcoplasmic/endoplasmic reticulum calcium ATPase with cyclopiazonic acid or thapsigargin), Ca2+ waves ceased to occur at a [Ca2+]SR that was higher than the control threshold. Furthermore, for a set [Ca2+]SR level the refractoriness of wave occurrence (Ca2+ wave latency) was prolonged during β-adrenergic stimulation, and was highly dependent on the extent that [Ca]SR exceeded the wave threshold. These data show that acute β-adrenergic stimulation increases the [Ca2+]SR threshold for Ca2+ waves, and therefore the primary cause of Ca2+ waves is the robust increase in [Ca2+]SR above this higher threshold level. Elevation of the [Ca2+]SR wave threshold and prolongation of wave latency represent potentially protective mechanisms against pro-arrhythmogenic Ca2+ release during β-adrenergic stimulation. PMID:22988136
Zhang, Jidong; Wang, Yan; Hu, Haijuan; Yang, Xiaohong; Tian, Zejun; Liu, Demin; Gu, Guoqiang; Zheng, Hongmei; Xie, Ruiqin; Cui, Wei
2016-01-01
Nifedipine gastrointestinal therapeutic system (GITS) is used to treat angina and hypertension. The authors aimed to study the early intervention impact on arterial stiffness and pulse wave velocity (PWV) independent of its blood-pressure-(BP) lowering effect in mild hypertensive patients. This single-center, single-arm, open-label, prospective, Phase IV study recruited patients with mild hypertension and increased PWV from December 2013 to December 2014 (N=138; age, 18-75 years; systolic blood pressure, 140-160 mmHg; diastolic BP, 90-100 mmHg; increased brachial-ankle pulse wave velocity [baPWV, ≥12 m/s]). Nifedipine GITS (30 mg/d) was administered for 24 weeks to achieve target BP of <140/90 mmHg. The dose was uptitrated at 60 mg/d in case of unsatisfactory BP reduction after 4 weeks. Primary study end point was the change in baPWV after nifedipine GITS treatment. Hemodynamic parameters (office BP, 24-hour ambulatory BP monitoring, and heart rate and adverse events) were evaluated at baseline and followed-up at 2, 4, 8, 12, 18, and 24 weeks. Majority of patients (n=117; 84.8%) completed the study. baPWV decreased significantly at 4 weeks compared with baseline (1,598.87±239.82 vs 1,500.89±241.15 cm/s, P <0.001), was stable at 12 weeks (1,482.24±215.14 cm/s, P <0.001), and remained steady through 24 weeks (1,472.58±205.01 cm/s, P <0.001). Office BP reduced from baseline to week 4 (154/95 vs 136/85 mmHg) and remained steady until 24 weeks. Nifedipine GITS significantly decreased 24-hour ambulatory BP monitoring ( P <0.001) after 24 weeks from baseline. Mean arterial pressure and pulse pressure were lowered significantly after 4, 12, and 24 weeks of treatment ( P <0.001). These changes in baPWV were significantly correlated with changes in systolic blood pressure, diastolic BP, and mean arterial pressure ( P <0.05), but not with changes in pulse pressure ( P >0.05). There were no other drug-related serious adverse events. Nifedipine GITS was considerably effective in reducing baPWV and BP, indicating improvement in arterial stiffness as early as 4 weeks.
A Millimeter-Wave Cavity-Backed Suspended Substrate Stripline Antenna
NASA Technical Reports Server (NTRS)
Simons, Rainee N.
1999-01-01
Future generation satellite communication systems in near-Earth orbit will operate at frequencies in the higher mm-wave frequency bands. These satellite systems require low-profile, high gain, light weight and low cost antennas for communications to and from Earth as well as for inter-satellite links (ISL). At higher mm-wave frequencies, the conductor loss of conventional microstrip line is high and consequently the feed network loss of patch antenna arrays is also high. The high loss lowers the array efficiency, and in addition lowers the G/T ratio in a receiving array. Recently a radial line slot antenna array has been demonstrated to have high gain and efficiency at 60 GHz. In this paper, the design, fabrication and characterization of a V-Band (50-75 GHz), cavity backed, circular aperture antenna with suspended substrate stripline (SSS) feed is presented.
Soanker, Radhika; Naidu, M U R; Raju, Sree Bhushan; Prasad, A Krishna; Rao, T Ramesh Kumar
2012-05-01
Blood pressure (BP) reduction is the major determinant of benefit provided by antihypertensive treatment. Although different drugs reduce peripheral BP to some extent, there may be a significant difference in their effect on central BP reduction. It has been shown that beta-blockers are efficient in reducing peripheral, but not central BP. This study was done to assess the effect of beta-1-blocker, nebivolol, in patients with essential hypertension on central aortic pressures and arterial stiffness. In this single arm, open-labeled study, 13 patients were given nebivolol, 5 mg orally once daily for 15 days. Primary outcome was change in central aortic pressure, and other measures of efficacy included changes in brachial BP, augmentation index (AIx%), AIx%@75 HR, augmentation pressure (AP), heart rate (HR), and carotid femoral pulse wave velocity (PWVcf). Nebivolol 5 mg significantly reduced central aortic pressures [systolic BP, 131.5-111.6 mmHg; diastolic BP, 96.3-81.7 mmHg; Mean Arterial Pressure (MAP), 111.3-94.0 mmHg (all P<0.0001), and Pulse Pressure (PP), 35.2-29.7 mmHg (P<0.01)]. AIx%@75 HR reduced from 29 to 21.6 (P<0.001) and PWVcf reduced from 8.6 to 7.2 m/s (P<0.001). One subject was lost to followup. Nebivolol 5 mg demonstrated antihypertensive efficacy in patients with essential hypertension by reducing not only peripheral brachial pressures, but also significantly reducing central aortic pressures, augmentation index, and carotid femoral pulse wave velocity, which is the marker of arterial stiffness.
Poster Presentation: Optical Test of NGST Developmental Mirrors
NASA Technical Reports Server (NTRS)
Hadaway, James B.; Geary, Joseph; Reardon, Patrick; Peters, Bruce; Keidel, John; Chavers, Greg
2000-01-01
An Optical Testing System (OTS) has been developed to measure the figure and radius of curvature of NGST developmental mirrors in the vacuum, cryogenic environment of the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center (MSFC). The OTS consists of a WaveScope Shack-Hartmann sensor from Adaptive Optics Associates as the main instrument, a Point Diffraction Interferometer (PDI), a Point Spread Function (PSF) imager, an alignment system, a Leica Disto Pro distance measurement instrument, and a laser source palette (632.8 nm wavelength) that is fiber-coupled to the sensor instruments. All of the instruments except the laser source palette are located on a single breadboard known as the Wavefront Sensor Pallet (WSP). The WSP is located on top of a 5-DOF motion system located at the center of curvature of the test mirror. Two PC's are used to control the OTS. The error in the figure measurement is dominated by the WaveScope's measurement error. An analysis using the absolute wavefront gradient error of 1/50 wave P-V (at 0.6328 microns) provided by the manufacturer leads to a total surface figure measurement error of approximately 1/100 wave rms. This easily meets the requirement of 1/10 wave P-V. The error in radius of curvature is dominated by the Leica's absolute measurement error of VI.5 mm and the focus setting error of Vi.4 mm, giving an overall error of V2 mm. The OTS is currently being used to test the NGST Mirror System Demonstrators (NMSD's) and the Subscale Beryllium Mirror Demonstrator (SBNM).
Assessments of Ali, Dome A, and Summit Camp for mm-wave Observations Using MERRA-2 Reanalysis
Kuo, Chao -Lin
2017-10-10
NASA's latest MERRA-2 reanalysis of the modern satellite measurements has made atmospheric data easily accessible with unprecedented uniformity, fidelity, and completeness. In this paper, these data are used to evaluate five sites for millimeter-wave (mm-wave) observations. These include two established sites (South Pole and Chajnantor, Atacama), and three new sites (Ali in Tibet, Dome A in Antarctica, and Summit Camp in Greenland). Atmospheric properties including precipitable water vapor (PWV), sky brightness temperature fluctuations, and ice and liquid water paths are derived and compared. Dome A emerges to be the best among those evaluated, with PWV and fluctuations smaller than themore » second-best site, South Pole, by more than a factor of 2. It is found that the higher site in Ali (6100 m) is on par with Cerro Chajnantor (5612 m) in terms of transmission and stability. The lower site in Ali (5250 m) planned for the first stage of observations at 90/150 GHz provides conditions comparable to those on the Chajnantor Plateau. These analyses confirm Ali to be an excellent mm-wave site in the Northern Hemisphere that will complement well-established Southern sites. According to MERRA-2 data, the observing conditions at Summit Camp are also comparable to Cerro Chajnantor. Furthermore, it is more affected by the presence of liquid water clouds.« less
Assessments of Ali, Dome A, and Summit Camp for mm-wave Observations Using MERRA-2 Reanalysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuo, Chao -Lin
NASA's latest MERRA-2 reanalysis of the modern satellite measurements has made atmospheric data easily accessible with unprecedented uniformity, fidelity, and completeness. In this paper, these data are used to evaluate five sites for millimeter-wave (mm-wave) observations. These include two established sites (South Pole and Chajnantor, Atacama), and three new sites (Ali in Tibet, Dome A in Antarctica, and Summit Camp in Greenland). Atmospheric properties including precipitable water vapor (PWV), sky brightness temperature fluctuations, and ice and liquid water paths are derived and compared. Dome A emerges to be the best among those evaluated, with PWV and fluctuations smaller than themore » second-best site, South Pole, by more than a factor of 2. It is found that the higher site in Ali (6100 m) is on par with Cerro Chajnantor (5612 m) in terms of transmission and stability. The lower site in Ali (5250 m) planned for the first stage of observations at 90/150 GHz provides conditions comparable to those on the Chajnantor Plateau. These analyses confirm Ali to be an excellent mm-wave site in the Northern Hemisphere that will complement well-established Southern sites. According to MERRA-2 data, the observing conditions at Summit Camp are also comparable to Cerro Chajnantor. Furthermore, it is more affected by the presence of liquid water clouds.« less
Assessments of Ali, Dome A, and Summit Camp for mm-wave Observations Using MERRA-2 Reanalysis
NASA Astrophysics Data System (ADS)
Kuo, Chao-Lin
2017-10-01
NASA’s latest MERRA-2 reanalysis of the modern satellite measurements has made atmospheric data easily accessible with unprecedented uniformity, fidelity, and completeness. In this paper, these data are used to evaluate five sites for millimeter-wave (mm-wave) observations. These include two established sites (South Pole and Chajnantor, Atacama), and three new sites (Ali in Tibet, Dome A in Antarctica, and Summit Camp in Greenland). Atmospheric properties including precipitable water vapor (PWV), sky brightness temperature fluctuations, and ice and liquid water paths are derived and compared. Dome A emerges to be the best among those evaluated, with PWV and fluctuations smaller than the second-best site, South Pole, by more than a factor of 2. It is found that the higher site in Ali (6100 m) is on par with Cerro Chajnantor (5612 m) in terms of transmission and stability. The lower site in Ali (5250 m) planned for the first stage of observations at 90/150 GHz provides conditions comparable to those on the Chajnantor Plateau. These analyses confirm Ali to be an excellent mm-wave site in the Northern Hemisphere that will complement well-established Southern sites. According to MERRA-2 data, the observing conditions at Summit Camp are also comparable to Cerro Chajnantor. However, it is more affected by the presence of liquid water clouds.
Sun, Zeqing; Sun, Anyu; Ju, Bing-Feng
2017-02-01
Guided-wave echoes from weak reflective pipe defects are usually interfered by coherent noise and difficult to interpret. In this paper, a deconvolution imaging method is proposed to reconstruct defect images from synthetically focused guided-wave signals, with enhanced axial resolution. A compact transducer, circumferentially scanning around the pipe, is used to receive guided-wave echoes from discontinuities at a distance. This method achieves a higher circumferential sampling density than arrayed transducers-up to 72 sampling spots per lap for a pipe with a diameter of 180 mm. A noise suppression technique is used to enhance the signal-to-noise ratio. The enhancement in both signal-to-noise ratio and axial resolution of the method is experimentally validated by the detection of two kinds of artificial defects: a pitting defect of 5 mm in diameter and 0.9 mm in maximum depth, and iron pieces attached to the pipe surface. A reconstructed image of the pitting defect is obtained with a 5.87 dB signal-to-noise ratio. It is revealed that a high circumferential sampling density is important for the enhancement of the inspection sensitivity, by comparing the images reconstructed with different down-sampling ratios. A modified full width at half maximum is used as the criterion to evaluate the circumferential extent of the region where iron pieces are attached, which is applicable for defects with inhomogeneous reflection intensity.
NASA Astrophysics Data System (ADS)
Xu, A. A.
2016-12-01
Existing research has shown consistent increase in global sea levels due to warming of the climate; since 1870, average global sea level has risen by about 20 cm. There are processes that scientists and coastal engineers can follow to estimate the erosion and flooding risk impacts for specific locations based on historical data. However, there are no methods available to assess the risk impacts for locations where little research has been conducted. In this study, we introduce a prototype to better predict sea level change and land loss using big data technology. Our approach combines cluster analysis and artificial intelligence to classify and calculate impacts for locations worldwide. Data from 235 locations (89 countries) on sea level change was gathered from NOAA data investigations and other research organizations, including beach profile data, shoreline length data, and GDP data. The rate of sea level rise varies from -18 to 21 mm/yr. We divide the data into 4 groups (Group A: +0 to 9mm, Group B: +10 to +20mm, Group C: -0 to -9mm, and Group D:-10 to -20mm). Our research focuses on types A and B only since both reflect increase on sea level rise. We find the correlation between the sea level rise and factors such as the economic parameter (α), sea level rise height (h), beach breaker wave (Hb), gravitational constant (g), period of wave (T), foreshore slope (i), and sand sizes (D). We conclude the sea level rise impact ($ lost) can be more scientifically and precisely predicted using our model.
NASA Astrophysics Data System (ADS)
Matsue, Kazuma; Arakawa, Masahiko; Yasui, Minami; Matsumoto, Rie; Tsujido, Sayaka; Takano, Shota; Hasegawa, Sunao
2015-08-01
Introduction: Recent spacecraft surveys clarified that asteroid surfaces were covered with regolith made of boulders and pebbles such as that found on the asteroid Itokawa. It was also found that surface morphologies of asteroids formed on the regolith layer were modified. For example, the high-resolution images of the asteroid Eros revealed the evidence of the downslope movement of the regolith layer, then it could cause the degradation and the erasure of small impact crater. One possible process to explain these observations is the regolith layer collapse caused by seismic vibration after projectile impacts. The impact-induced seismic wave might be an important physical process affecting the morphology change of regolith layer on asteroid surfaces. Therefore, it is significant for us to know the relationship between the impact energy and the impact-induced seismic wave. So in this study, we carried out impact cratering experiments in order to observe the seismic wave propagating through the target far from the impact crater.Experimental method: Impact cratering experiments were conducted by using a single stage vertical gas gun set at Kobe Univ and a two-stage vertical gas gun set at ISAS. We used quartz sands with the particle diameter of 500μm, and the bulk density of 1.48g/cm3. The projectile was a ball made of polycarbonate with the diameter of 4.75mm and aluminum, titan, zirconia, stainless steel, cupper, tungsten carbide projectile with the diameter of 2mm. These projectiles were launched at the impact velocity from 0.2 to 7km/s. The target was set in a vacuum chamber evacuated below 10 Pa. We measured the seismic wave by using a piezoelectric uniaxial accelerometer.Result: The impact-induced seismic wave was measured to show a large single peak and found to attenuate with the propagation distance. The maximum acceleration of the seismic wave was recognized to have a good relationship with the normalized distance x/R, where x is the propagation distance and R is the crater radius, irrespective of the impact velocities: gmax = 160(x/R)-2.98.
Electromagnetic (EM) Wave Attachment to Laser Plasma Filaments
2009-05-01
this phenomenon over a laboratory scale distance and observed that the channel energy, diameter, and modulated spectrum all remained relatively ...are oriented parallel to one another and insulated from one another to maintain a calculated separation. The TEM waves also represent plane waves...orientation, the electric field will point along the direction of the wire axis. The wire is 0.8 mm copper wire, fixed at both ends and insulated at
On Wave-Ice Interaction in the Arctic Marginal Ice Zone: Dispersion, Attenuation, and Ice Response
2016-06-01
PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 2. REPORT TYPE1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE 6. AUTHOR(S) 8. PERFORMING...schemes and contributes to a change of wave height (and direction) analogous to shoaling and refraction. A method for jointly measuring dispersion and...46 APPENDEX B: WAVE HEIGHTS MEASURED IN ARTIC ICE
Laboratory Measurements of Celestial Solids
NASA Technical Reports Server (NTRS)
Sievers, A. J.; Beckwith, S. V. W.
1997-01-01
Our experimental study has focused on laboratory measurements of the low temperature optical properties of a variety of astronomically significant materials in the infrared and mm-wave region of the spectrum. Our far infrared measurements of silicate grains with an open structure have produced a variety of unusual results: (1) the low temperature mass opacity coefficient of small amorphous 2MgO(central dot)SiO2 and MgO(central dot)2SiO2 grains are many times larger than the values previously used for interstellar grain material; (2) all of the amorphous silicate grains studied possess the characteristic temperature dependent signature associated with two level systems in bulk glass; and (3) a smaller but nonzero two level temperature dependence signature is also observed for crystalline particles, its physical origin is unclear. These laboratory measurements yield surprisingly large and variable values for the mm-wave absorption coefficients of small silicate particles similar to interstellar grains, and suggest that the bulk absorptivity of interstellar dust at these long wavelengths will not be well known without such studies. Furthermore, our studies have been useful to better understand the physics of the two level absorption process in amorphous and crystalline grains to gain confidence in the wide applicability of these results.
NASA Astrophysics Data System (ADS)
Nogo, Kosuke; Mori, Keita; Qi, Wei; Hosono, Satsuki; Kawashima, Natsumi; Nishiyama, Akira; Wada, Kenji; Ishimaru, Ichiro
2016-03-01
We proposed the ultrasonic-assisted spectroscopic imaging for the realization of blood-glucose-level monitoring during dialytic therapy. Optical scattering and absorption caused by blood cells deteriorate the detection accuracy of glucose dissolved in plasma. Ultrasonic standing waves can agglomerate blood cells at nodes. In contrast, around anti-node regions, the amount of transmitted light increases because relatively clear plasma appears due to decline the number of blood cells. Proposed method can disperse the transmitted light of plasma without time-consuming pretreatment such as centrifugation. To realize the thumb-size glucose sensor which can be easily attached to dialysis tubes, an ultrasonic standing wave generator and a spectroscopic imager are required to be small. Ultrasonic oscillators are ∅30[mm]. A drive circuit of oscillators, which now size is 41×55×45[mm], is expected to become small. The trial apparatus of proposed one-shot Fourier spectroscopic imager, whose size is 30×30×48[mm], also can be little-finger size in principal. In the experiment, we separated the suspension mixed water and micro spheres (Θ10[mm) into particles and liquid regions with the ultrasonic standing wave (frequency: 2[MHz]). Furthermore, the spectrum of transmitted light through the suspension could be obtained in visible light regions with a white LED.
Models of brachial to finger pulse wave distortion and pressure decrement.
Gizdulich, P; Prentza, A; Wesseling, K H
1997-03-01
To model the pulse wave distortion and pressure decrement occurring between brachial and finger arteries. Distortion reversion and decrement correction were also our aims. Brachial artery pressure was recorded intra-arterially and finger pressure was recorded non-invasively by the Finapres technique in 53 adult human subjects. Mean pressure was subtracted from each pressure waveform and Fourier analysis applied to the pulsations. A distortion model was estimated for each subject and averaged over the group. The average inverse model was applied to the full finger pressure waveform. The pressure decrement was modelled by multiple regression on finger systolic and diastolic levels. Waveform distortion could be described by a general, frequency dependent model having a resonance at 7.3 Hz. The general inverse model has an anti-resonance at this frequency. It converts finger to brachial pulsations thereby reducing average waveform distortion from 9.7 (s.d. 3.2) mmHg per sample for the finger pulse to 3.7 (1.7) mmHg for the converted pulse. Systolic and diastolic level differences between finger and brachial arterial pressures changed from -4 (15) and -8 (11) to +8 (14) and +8 (12) mmHg, respectively, after inverse modelling, with pulse pressures correct on average. The pressure decrement model reduced both the mean and the standard deviation of systolic and diastolic level differences to 0 (13) and 0 (8) mmHg. Diastolic differences were thus reduced most. Brachial to finger pulse wave distortion due to wave reflection in arteries is almost identical in all subjects and can be modelled by a single resonance. The pressure decrement due to flow in arteries is greatest for high pulse pressures superimposed on low means.
Fast discharge in a plasma gun with hemispherical insulator
NASA Astrophysics Data System (ADS)
Antsiferov, P. S.; Dorokhin, L. A.; Sidelnikov, Yu. V.; Koshelev, K. N.
2009-05-01
A method of creation of hot dense plasma is proposed. It is based on cumulation of a shockwave, which originates on a hemispherical surface of insulator of plasma gun. The results of first experiments are presented. The shock wave is driven by fast electrical discharge (dI /dt>1012 A/s). The inductive storage with semiconductor opening switch is used as a current driver. Time resolved pin-hole images and vacuum ultraviolet (vuv) spectra are studied. Shockwaves from hemispherical insulator with 4 mm radius create plasma with a form of column about 1 mm diameter and 3-4 mm length. vuv spectra contain the lines of Ar ions that corresponds to the electron temperature about 20 eV. Possible practical application is discussed.
NASA Astrophysics Data System (ADS)
Othmani, Cherif; Takali, Farid; Njeh, Anouar
2017-12-01
Guided wave devices have recently become one of the most important applications in the industry because such waves are directly related to applications in sensor technology, chemical sensing, agricultural science, fields of bio-sensing and surface acoustic wave (SAW) devices that are used in electronic filters and signal processing. On that account, this numerical investigation aims to study the propagation behavior of guided Lamb waves in a (1-x)Pb(Mg1/3Nb2/3)O3- x PbTiO3 [PMN- x PT] ( x=0.29 or 0.33) piezoelectric single crystal plate. In fact, the PMN- xPT ( x=0.29 or 0.33) piezoelectric crystals are being polarized along [001]c, [011]c and [111]c of the cubic reference directions so that the macroscopic symmetries are tetragonal 4 mm, orthogonal mm2 and rhombohedral 3 m, respectively. Both open- and short-circuit conditions are considered. Here, the Legendre polynomial method is proposed to solve the guided Lamb waves equations. The validity of the proposed method is illustrated by comparison with the ordinary differential equation (ODE). The convergence of this method is discussed. Consequently, the converged results are obtained with very low truncation order M . This constitutes a major advantage of the present method when compared with the other matrix methods. There is cross-crossings among multiple modes for both symmetric ( Sn) and the anti-symmetric ( An) guided Lamb waves propagation. A displacement field has been illustrated to judge whether Sn and An modes cross with each other. Moreover, electric displacement, stress field and electric potential for the open-circuit case were presented for both S0 and A0 Lamb modes.
NASA Astrophysics Data System (ADS)
Preusse, Peter; Dörnbrack, Andreas; Eckermann, Stephen D.; Riese, Martin; Schaeler, Bernd; Bacmeister, Julio T.; Broutman, Dave; Grossmann, Klaus U.
2002-09-01
The Cryogenic Infrared Spectrometers and Telescopes for the Atmosphere (CRISTA) instrument measured stratospheric temperatures and trace species concentrations with high precision and spatial resolution during two missions. The measuring technique is infrared limb-sounding of optically thin emissions. In a general approach, we investigate the applicability of the technique to measure gravity waves (GWs) in the retrieved temperature data. It is shown that GWs with wavelengths of the order of 100-200 km horizontally can be detected. The results are applicable to any instrument using the same technique. We discuss additional constraints inherent to the CRISTA instrument. The vertical field of view and the influence of the sampling and retrieval imply that waves with vertical wavelengths ~3-5 km or larger can be retrieved. Global distributions of GW fluctuations were extracted from temperature data measured by CRISTA using Maximum Entropy Method (MEM) and Harmonic Analysis (HA), yielding height profiles of vertical wavelength and peak amplitude for fluctuations in each scanned profile. The method is discussed and compared to Fourier transform analyses and standard deviations. Analysis of data from the first mission reveals large GW amplitudes in the stratosphere over southernmost South America. These waves obey the dispersion relation for linear two-dimensional mountain waves (MWs). The horizontal structure on 6 November 1994 is compared to temperature fields calculated by the Pennsylvania State University (PSU)/National Center for Atmospheric Research (NCAR) mesoscale model (MM5). It is demonstrated that precise knowledge of the instrument's sensitivity is essential. Particularly good agreement is found at the southern tip of South America where the MM5 accurately reproduces the amplitudes and phases of a large-scale wave with 400 km horizontal wavelength. Targeted ray-tracing simulations allow us to interpret some of the observed wave features. A companion paper will discuss MWs on a global scale and estimates the fraction that MWs contribute to the total GW energy (Preusse et al., in preparation, 2002).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Antonov, O.; Efimov, S.; Gurovich, V. Tz.
The results of visible spectroscopy of the plasma formed inside a copper capillary placed at the equatorial plane of an underwater electrically exploded spherical wire array (30 mm in diameter; 40 wires, each of 100 μm in diameter) are reported. In the experiments, a pulsed power generator with current amplitude of ∼300 kA and rise time of ∼1.1 μs was used to produce wire array explosion accompanied by the formation of a converging strong shock wave. The data obtained support the assumption of uniformity of the shock wave along the main path of its convergence. The spectroscopic measurements show that this rather simple methodmore » of formation of a converging strong shock wave can be used successfully for studying the shock wave's interaction with matter and the evaporation processes of atoms from a target.« less
High resolution wavenumber analysis for investigation of arterial pulse wave propagation
NASA Astrophysics Data System (ADS)
Hasegawa, Hideyuki; Sato, Masakazu; Irie, Takasuke
2016-07-01
The propagation of the pulse wave along the artery is relatively fast (several m/s), and a high-temporal resolution is required to measure pulse wave velocity (PWV) in a regional segment of the artery. High-frame-rate ultrasound enables the measurement of the regional PWV. In analyses of wave propagation phenomena, the direction and propagation speed are generally identified in the frequency-wavenumber space using the two-dimensional Fourier transform. However, the wavelength of the pulse wave is very long (1 m at a propagation velocity of 10 m/s and a temporal frequency of 10 Hz) compared with a typical lateral field of view of 40 mm in ultrasound imaging. Therefore, PWV cannot be identified in the frequency-wavenumber space owing to the low resolution of the two-dimensional Fourier transform. In the present study, PWV was visualized in the wavenumber domain using phases of arterial wall acceleration waveforms measured by high-frame-rate ultrasound.
Marine Exposure of Preservative-Treated Small Wood Panels.
1981-04-01
southern noria attack and that creosote impedes teredine attack, pine sapwood , 0.24 to 0.39 growth rings per mm (6-8/in.), a study was initiated in 1969...whereas in piling, wave action and abrasion from The column showing "months exposure to index below floating debris must break away surface areas to
A novel graded density impactor
NASA Astrophysics Data System (ADS)
Winter, Ron; Cotton, Matthew; Harris, Ernest; Eakins, Daniel; Chapman, David
2013-06-01
Ramp loading using graded-density-impactors as flyers in plate impact experiments can yield useful information about the dynamic properties of the loaded material. Selective Laser Melting, an additive manufacture technique, was used to fabricate a graded-density flyer, termed the ``bed of nails'' (BON). A 2 mm thick x 100 mm diameter solid disc of stainless steel formed a base for an array of tapered spikes of length 6 mm and spaced 1 mm apart. Two experiments to test the concept were performed at impact velocities of 900 m/s and 1100 m/s using the 100 mm gas gun at The Institute of Shock Physics, Imperial College, London. In each experiment a BON flyer was impacted onto a copper buffer plate which helped to smooth out perturbations in the wave profile. The ramp delivered to the copper buffer was in turn transmitted to three tantalum targets of thicknesses 3, 5 and 7 mm, mounted in contact with the back face of the copper. Heterodyne velocimetry was used to measure the velocity-time history, at the back faces of the tantalum discs. The wave profiles display a smooth increase in free surface velocity over a period of about 2.5 microseconds. The measured profiles have been analysed to generate a stress vs. volume curve for tantalum.
Biological Effects of Millimeter-Wave Irradiation.
1987-04-01
presence of lines in Raman spectra of baterial cells cm- 1) of the computer driven spectrometer. This is can be claimed to be "...non questionable...the boundary between the in- yeast" ’ was not altered by exposure to mm waves. In 1968. ternal and the external cell environment , membranes also with
Ice detection and classification on an aircraft wing with ultrasonic shear horizontal guided waves.
Gao, Huidong; Rose, Joseph L
2009-02-01
Ice accumulation on airfoils has been identified as a primary cause of many accidents in commercial and military aircraft. To improve aviation safety as well as reduce cost and environmental threats related to aircraft icing, sensitive, reliable, and aerodynamically compatible ice detection techniques are in great demand. Ultrasonic guided-wave-based techniques have been proved reliable for "go" and "no go" types of ice detection in some systems including the HALO system, in which the second author of this paper is a primary contributor. In this paper, we propose a new model that takes the ice layer into guided-wave modeling. Using this model, the thickness and type of ice formation can be determined from guided-wave signals. Five experimental schemes are also proposed in this paper based on some unique features identified from the guided- wave dispersion curves. A sample experiment is also presented in this paper, where a 1 mm thick glaze ice on a 2 mm aluminum plate is clearly detected. Quantitative match of the experiment data to theoretical prediction serves as a strong support for future implementation of other testing schemes proposed in this paper.
Vorreuther, R; Corleis, R; Klotz, T; Bernards, P; Engelmann, U
1995-03-01
It is known that electrohydraulic lithotripsy (EHL) during ureteroscopy may cause ureteral damage. To evaluate this trauma potential, find its mechanism and make it possible to avoid it, our research employed photographic evaluation, tissue studies, shock wave measurements and disintegration tests. The setup included a 3.3 F probe attached to an experimental generator with adjustable voltages and capacities providing energies from 25 mJ. to 1300 mJ. per pulse. In general, we distinguish between two traumatic mechanisms: (1) After placing the probe directly on the mucosa the rapid initial plasma penetrates the tissue resulting in a small, nonthermal, punched-like defect, whose depth depends on the energy applied. This trauma has minor clinical implications and is avoided by maintaining a minimum safety distance of 1 mm.; (2) According to physics, each plasma is followed by a cavitation bubble. The maximum size of this bubble depends on the energy applied and ranges from 3 mm. (25 mJ) to > 15 mm. (1300 mJ). In proportion to the bubble size, the ureteral wall may be distended or disrupted, even when the probe is not in direct contact with the mucosa. Therefore, the goal should be to obtain a low energy pressure pulse with high disintegration efficacy. Our evaluation of the pressure waves revealed that the selection of a high voltage and a low capacity leads to short and steep "laser-like" pulses. These pulses have a significant higher impact on stone disintegration than the broader pulses of the same energy provided by currently available generators.
Rejection of atrial sensing artifacts by a pacing lead with short tip-to-ring spacing.
Nash, A; Fröhlig, G; Taborsky, M; Stammwitz, E; Maru, F; Bouwens, L H M; Celiker, C
2005-01-01
The ability of a new pacing lead design, with a 10 mm tip-to-ring spacing, to facilitate rejection of sensed far field R-waves and myopotentials was evaluated. Measurements were performed in 66 patients. The occurrence of far field R-wave sensing and myopotential sensing was determined by means of the surface ECG and the ECG markers provided by the pacemaker. At an atrial sensitivity of 0.25 mV and an atrial blanking of 50 ms far field R-wave sensing was observed in 12 patients (18.2%) and at an atrial sensitivity of 1.0 mV no far-field R-wave sensing was observed. Myopotentials were sensed in 3 patients. In all patients the measured P-wave amplitude was at least twice the estimated amplitude of the far field R-wave at an atrial blanking of 50 ms. The results from this study show that a small tip-to-ring spacing allows for programming of a high atrial sensitivity and short atrial blanking with an acceptably low risk for atrial artifact sensing.
The Effect of Saturation on Shear Wave Anisotropy in a Transversely Isotropic Medium
NASA Astrophysics Data System (ADS)
Li, W.; Pyrak-Nolte, L. J.
2010-12-01
Seismic monitoring of fluid distributions in the subsurface requires an understanding of the effect of fluid saturation on the anisotropic properties of layered media. Austin Chalk is a carbonate rock composed mainly of calcite (99.9%) with fine bedding caused by a weakly-directed fabric. In this paper, we assess the shear-wave anisotropy of Austin Chalk and the effect of saturation on interpreting anisotropy based on shear wave velocity, attenuation and spectral content as a function of saturation. In the laboratory, we performed full shear-waveform measurements on several dry cubic samples of Austin Chalk with dimensions 50mm x 50mm x 50mm. Two shear-wave contact transducers (central Frequency 1 MHz) were use to send and receive signals. Data was collected for three orthogonal orientations of the sample and as a function of shear wave polarization relative to the layers in the sample. For the waves propagated parallel to the layers, both fast and slow shear waves were observed with velocities of 3444 m/s and 3193 m/s, respectively. It was noted that the minimum and maximum shear wave velocities did not occur when the shear wave polarization were perpendicular or parallel to the layering in the sample but occurred at an orientation of ~25 degrees from the normal to the layers. The sample was then vacuum saturated with water for approximately ~15 hours. The same measurements were performed on the saturated sample as those on the dry sample. Both shear wave velocities observed decreased upon water-saturation with corresponding velocities of 3155 m/s and 2939 m/s, respectively. In the dry condition the difference between the fast and slow shear wave velocities was 250 m/s. This difference decreased to 215 m/s after fluid saturation. In both the dry and saturated condition, the shear wave velocity for waves propagated perpendicularly to the layers was independent of polarization and had the same magnitude as that of the slow shear wave. A wavelet analysis was performed to determine changes in the spectral content of the signals upon saturation as well velocity dispersion. We found that (1) low frequency components exhibit a larger difference in time delay between the fast and slow shear waves for the water-saturated condition than for the dry condition; (2) that high frequency components have relatively small differences in time delay between the dry and saturated conditions; and (3) the dominant frequency shifted to lower frequencies for the fast shear wave upon saturation while no change in dominant frequency was observed for the slow shear wave upon saturation. Thus, fluid saturation affects shear velocity as well as the spectral content of the signal. Acknowledgments: The authors wish to acknowledge support of this work by the Geosciences Research Program, Office of Basic Energy Sciences US Department of Energy (DE-FG02-09ER16022), by Exxon Mobil Upstream Research Company and the GeoMathematical Imaging Group at Purdue University.
Sharman, James E; Hare, James L; Thomas, Scott; Davies, Justin E; Leano, Rodel; Jenkins, Carly; Marwick, Thomas H
2011-08-01
A hypertensive response to exercise (HRE; defined as normal clinic blood pressure (BP) and exercise systolic BP (SBP) ≥210 mm Hg in men or ≥190 mm Hg in women, or diastolic BP (DBP) ≥105 mm Hg) independently predicts mortality. The mechanisms remain unclear but may be related to masked hypertension. This study aimed to assess the prevalence of masked hypertension and its association with cardiovascular risk factors, including left ventricular (LV) mass, in patients with a HRE. Comprehensive clinical and echocardiographic evaluation (including central BP, aortic pulse wave velocity by tonometry) and 24-h ambulatory BP monitoring (ABPM) were performed in 72 untreated patients with HRE (aged 54 ± 9 years; 60% male; free from coronary artery disease confirmed by exercise stress echocardiography). Masked hypertension was defined according to guidelines as daytime ABPM ≥135/85 mm Hg and clinic BP <140/90 mm Hg. Masked hypertension was present in 42 patients (58%). These patients had higher LV mass index (41.5 ± 8.7 g/m(2.7) vs. 35.9 ± 8.5 g/m(2.7); P = 0.01), LV relative wall thickness (RWT; 0.42 ± 0.09 vs. 0.37 ± 0.06; P = 0.004) and exercise SBP (222 ± 17 mm Hg vs. 212 ± 14 mm Hg; P = 0.01), but no significant difference in aortic pulse wave velocity or central pulse pressure (P > 0.05 for both). The strongest independent determinant of LV mass index was the presence of masked hypertension (unstandardized β = 5.6; P = 0.007), which was also independently related to LV RWT (unstandardized β = 0.04; P = 0.03). Masked hypertension is highly prevalent in HRE patients with a normal resting office BP and is associated with increased LV mass index and RWT. Clinicians should consider measuring ABPM or home BP in HRE patients.
Laboratory studies of near-grazing impulsive sound propagating over rough water.
Qin, Qin; Lukaschuk, Sergei; Attenborough, Keith
2008-08-01
Acoustic impulses due to an electrical spark source (main acoustic energy near 15 kHz) have been measured after propagating near to the water surface in a shallow container resting on a vibrating platform. Control of the platform vibration enabled control of water wave amplitudes. Analysis of the results reveals systematic variations in the received acoustic waveforms as the mean trough-to-crest water wave amplitude is increased up to 7 mm. The amplitudes of the peaks corresponding to specular reflections are reduced and the variability in the tails of the waveforms is increased.
Pressures, flow, and brain oxygenation during plateau waves of intracranial pressure.
Dias, Celeste; Maia, Isabel; Cerejo, António; Varsos, Georgios; Smielewski, Peter; Paiva, José-Artur; Czosnyka, Marek
2014-08-01
Plateau waves are common in traumatic brain injury. They constitute abrupt increases of intracranial pressure (ICP) above 40 mmHg associated with a decrease in cerebral perfusion pressure (CPP). The aim of this study was to describe plateau waves characteristics with multimodal brain monitoring in head injured patients admitted in neurocritical care. Prospective observational study in 18 multiple trauma patients with head injury admitted to Neurocritical Care Unit of Hospital Sao Joao in Porto. Multimodal systemic and brain monitoring of primary variables [heart rate, arterial blood pressure, ICP, CPP, pulse amplitude, end tidal CO₂, brain temperature, brain tissue oxygenation pressure, cerebral oximetry (CO) with transcutaneous near-infrared spectroscopy and cerebral blood flow (CBF)] and secondary variables related to cerebral compensatory reserve and cerebrovascular reactivity were supported by dedicated software ICM+ ( www.neurosurg.cam.ac.uk/icmplus) . The compiled data were analyzed in patients who developed plateau waves. In this study we identified 59 plateau waves that occurred in 44% of the patients (8/18). During plateau waves CBF, cerebrovascular resistance, CO, and brain tissue oxygenation decreased. The duration and magnitude of plateau waves were greater in patients with working cerebrovascular reactivity. After the end of plateau wave, a hyperemic response was recorded in 64% of cases with increase in CBF and brain oxygenation. The magnitude of hyperemia was associated with better autoregulation status and low oxygenation levels at baseline. Multimodal brain monitoring facilitates identification and understanding of intrinsic vascular brain phenomenon, such as plateau waves, and may help the adequate management of acute head injury at bed side.
NASA Astrophysics Data System (ADS)
Anisimov, V. N.; Kozolupenko, A. P.; Sebrant, A. Yu
1988-12-01
An experimental investigation was made of the plasma transparency to heating radiation in capillaries when absorption waves propagated in these capillaries as a result of interaction with a CO2 laser pulse of 5-μs duration. When the length of the capillary was in excess of 20 mm, total absorption of the radiation by the plasma was observed at air pressures of 1-100 kPa. When the capillary length was 12 mm, a partial recovery of the transparency took place. A comparison was made with the dynamics and recovery of the plasma transparency when breakdown of air took place near the free surface.
Retina imaging system with adaptive optics for the eye with or without myopia
NASA Astrophysics Data System (ADS)
Li, Chao; Xia, Mingliang; Jiang, Baoguang; Mu, Quanquan; Chen, Shaoyuan; Xuan, Li
2009-04-01
An adaptive optics system for the retina imaging is introduced in the paper. It can be applied to the eye with myopia from 0 to 6 diopters without any adjustment of the system. A high-resolution liquid crystal on silicon (LCOS) device is used as the wave-front corrector. The aberration is detected by a Shack-Harmann wave-front sensor (HASO) that has a Root Mean Square (RMS) measurement accuracy of λ/100 ( λ = 0.633 μm). And an equivalent scale model eye is constructed with a short focal length lens (˜18 mm) and a diffuse reflection object (paper screen) as the retina. By changing the distance between the paper screen and the lens, we simulate the eye with larger diopters than 5 and the depth of field. The RMS value both before and after correction is obtained by the wave-front sensor. After correction, the system reaches the diffraction-limited resolution approximately 230 cycles/mm at the object space. It is proved that if the myopia is smaller than 6 diopters and the depth of field is between -40 and +50 mm, the system can correct the aberration very well.
A Two-Color Fourier Transform Mm-Wave Spectrometer for Gas Analysis Operating from 260-295 GHZ
NASA Astrophysics Data System (ADS)
Steber, Amanda L.; Harris, Brent J.; Lehmann, Kevin K.; Pate, Brooks H.
2013-06-01
We have designed a two-color mm-wave spectrometer for Fourier transform mm-wave spectroscopy that uses consumer level components for the tunable synthesizers, digital control of the pulse modulators, and digitization of the coherent free induction decay (FID). The excitation pulses are generated using an x24 active multiplier chain (AMC) that produces a peak power of 30 mW. The microwave input to the AMC is generated in a frequency up conversion circuit that accepts a microwave input frequency from about 2-4 GHz. This circuit also generates the input to the mm-wave subhamonic mixer that creates the local oscillator from a separate 2-4 GHz microwave input. Excitation pulses at two independently tunable frequencies are generated using a dual-channel source based on a low-cost, wideband synthesizer integrated circuit (Valon Technology Model 5008). The outputs of the synthesizer are pulse modulated using a PIN diode switch that is driven using the arbitrary waveform generator (AWG) output of a USB-controlled high-speed digitizer / arbitrary waveform generator combination unit (Tie Pie HS-5 530 XM). The two pulses are combined using a Wilkinson power divider before input to the up conversion circuit. The FID frequency is down converted in a two-stage mixing process to 65 MHz. The two LO frequencies used in the receiver are provided by a second Valon 5008. The FID is digitized at 200 MSamples/s using the 12-bit Tie Pie digitizer. The digital oscilloscope (and its AWG channel) and the two synthesizers use a 10 MHz reference signal from a Rubidium clock to permit time-domain signal averaging. A key feature of the digital oscilloscope is its deep memory of 32 Mpts (complemented by the 64 Mpt memory in the 240 MS/s AWG). This makes it possible to perform several one- and two-color coherent measurements, including pulse echoes and double-resonance spectroscopy, in a single "readout" experiment to speed the analysis of mm-wave rotational spectra. The spectrometer sensitivity and frequency accuracy are illustrated by high-speed measurements of OCS rotational transitions for low-abundance isotopes. Examples of pulse echo measurements to determine the collisional relaxation rate and two-color double-resonance measurements to confirm the presence of a molecular species will be illustrated using OCS as the room-temperature gas sample.
Joint Services Electronics Program. Appendix
1992-11-01
the accu- clude surface waves, creeping waves, multiple racy, convergence, and CPU times for the MM diffractions, shadowing effects , etc. A second ad...Method which is an approximation to the true current J Jn= A /m on the strip. The next section will discuss the - computation of the far zone...to the cavity (0 part of the incident plane wave captured by interior E•,. After a background discussion of the aperture at the open end is divided
Webster, Louise M; Myers, Jenny E; Nelson-Piercy, Catherine; Harding, Kate; Cruickshank, J Kennedy; Watt-Coote, Ingrid; Khalil, Asma; Wiesender, Cornelia; Seed, Paul T; Chappell, Lucy C
2017-11-01
Data from randomized controlled trials to guide antihypertensive agent choice for chronic hypertension in pregnancy are limited; this study aimed to compare labetalol and nifedipine, additionally assessing the impact of ethnicity on treatment efficacy. Pregnant women with chronic hypertension (12 +0 -27 +6 weeks' gestation) were enrolled at 4 UK centers (August 2014 to October 2015). Open-label first-line antihypertensive treatment was randomly assigned: labetalol- (200-1800 mg/d) or nifedipine-modified release (20-80 mg/d). Analysis included 112 women (98%) who completed the study (labetalol n=55, nifedipine n=57). Maximum blood pressure after randomization was 161/101 mm Hg with labetalol versus 163/105 mm Hg with nifedipine (mean difference systolic: 1.2 mm Hg [-4.9 to 7.2 mm Hg], diastolic: 3.3 mm Hg [-0.6 to 7.3 mm Hg]). Mean blood pressure was 134/84 mm Hg with labetalol and 134/85 mm Hg with nifedipine (mean difference systolic: 0.3 mm Hg [-2.8 to 3.4 mm Hg], and diastolic: -1.9 mm Hg [-4.1 to 0.3 mm Hg]). Nifedipine use was associated with a 7.4-mm Hg reduction (-14.4 to -0.4 mm Hg) in central aortic pressure, measured by pulse wave analysis. No difference in treatment effect was observed in black women (n=63), but a mean 4 mm Hg reduction (-6.6 to -0.8 mm Hg; P =0.015) in brachial diastolic blood pressure was observed with labetalol compared with nifedipine in non-black women (n=49). Labetalol and nifedipine control mean blood pressure to target in pregnant women with chronic hypertension. This study provides support for a larger definitive trial scrutinizing the benefits and side effects of first-line antihypertensive treatment. URL: https://www.isrctn.com. Unique identifier: ISRCTN40973936. © 2017 American Heart Association, Inc.
The correlation between the amplitude of Osborn wave and core body temperature.
Omar, Hesham R; Camporesi, Enrico M
2015-08-01
Several reports illustrate an inverse correlation between the Osborn wave (J wave) amplitude and core body temperature. We attempted to study the strength of this correlation. We reviewed all articles reporting hypothermic J waves from 1950-2014 for patient demographics, core body temperature in Celsius (°C), amplitude of the J wave in millimeters (mm), lead with the highest amplitude of J wave, presence of acidosis, PO2, electrolytes and outcome. In cases with more than one electrocardiogram (ECG), the respective core body temperature and J wave amplitude of each ECG were recorded. The main study outcome is to evaluate the correlation between the J wave amplitude and core body temperature in the admission ECG. We have also examined the strength of this relationship in cases with more than one ECG. We attempted to find the most frequent lead that recorded the highest amplitude of the J wave in addition to the correlation between the amplitude of J wave and pH. We found 64 articles comprising a total of 68 cases. When analyzing only cases with more than one reported ECG, there was a strong inverse correlation (r = - 0.682, p<0.001) between J wave amplitude and body temperature: however, when analyzing admission ECG of all cases, the correlation was only moderate (r = - 0.410, p<0.001). The lead with the highest amplitude of the J wave was V4 (44% of the cases, p<0.001) followed by V3 (23.7% of the cases, p<0.001). The amplitude of the J wave in the admission ECG of hypothermic patients may not accurately predict the core body temperature. © The European Society of Cardiology 2014.
The Impact of Standard Semiconductor Fabrication Processes on Polycrystalline Nb Thin Film Surfaces
NASA Technical Reports Server (NTRS)
Brown, Ari David; Barrentine, Emily M.; Moseley, Samuel H.; Noroozian, Omid; Stevenson, Thomas
2011-01-01
Polycrystalline superconducting Nb thin films are extensively used for submillimeter and millimeter transmission line applications and, less commonly, used in microwave kinetic inductance detector (MKID) applications. The microwave and mm-wave loss in these films is impacted, in part, by the presence of surface nitrides and oxides. In this study, glancing incidence x-ray diffraction was used to identify the presence of niobium nitride and niobium monoxide surface layers on Nb thin films which had been exposed to chemicals used in standard photolithographic processing. A method of mitigating the presence of ordered niobium monoxide surface layers is presented. Furthermore, we discuss the possibility of using glancing incidence x-ray diffraction as a non-destructive diagnostic tool for evaluating the quality of Nb thin films used in MKIDs and transmission lines. For a given fabrication process, we have both the x-ray diffraction data of the surface chemistry and a measure of the mm-wave and microwave loss, the latter being made in superconducting resonators.
VizieR Online Data Catalog: The mm and sub-mm spectra of 13C-glycolaldehydes (Haykal+, 2013)
NASA Astrophysics Data System (ADS)
Haykal, I.; Motiyenko, R. A.; Margules, L.; Huet, T. R.
2012-11-01
To allow the detection of the 13C-isotopologues of glycolaldeh the interstellar medium, their rotational spectra in the millimeter and submillimeter-wave regions were studied. The spectra of 13CH2OHCHO and CH2OH13CHO were recorded in the 150-945GHz spectral range in the laboratory using a solid-state submillimeter-wave spectrometer in Lille. The observed line frequencies were measured with accuracy, better than 30kHz up to 700GHz and 50kHz above. The analysis was performed using a standard Watson Hamiltonian. Around 10000 new lines were identified for each isotopologue. The spectroscopic parameters were determined for the ground and the three lowest vibrational states, respectively up to 945 and 630GHz. Previous microwave assignments of 13CH2OHCHO were not confirmed. The provided line-lists and sets of molecular parameters meet the needs for a first astrophysical search of 13C-glycolaldehydes. (2 data files).
In-Plane Ultrasound Propagation in an Elastic Silicone Tube as a Function of Tension
NASA Astrophysics Data System (ADS)
Rajakenttä, Tina; Salmi, Ari; Akujärvi, Altti; Haapalainen, Jonne; Hæggström, Edward
2007-03-01
The mechanical properties of a silicone tube blood vessel phantom (outer radius 4.04±0.04 mm and wall thickness 1.00±0.02 mm) carrying in-plane ultrasound wave propagation, was studied as function of applied axial tension. A 23 kHz, 1-cycle square signal was excited into the tube with a piezoceramic pickup and received with an inductive pickup. The wave phase velocities in the tube were determined by measuring the time-of-flight (TOF) at different inter-transducer distances. The longitudinal mode sound velocity ranged from 83 m/s to 88 m/s, and from 51 m/s to 58 m/s for the shear mode respectively with tensions ranging from 31 to 364 kPa. This compares with the FEM estimate. A laser-Doppler vibrometer (LDV) detected an out-of-plane mode propagating along the tube. An increase in the sound velocity caused by artificially induced lesions was detected.
The Impact of Standard Semiconductor Fabrication Processes on Polycrystalline Nb Thin Film Surfaces
NASA Technical Reports Server (NTRS)
Brown, Ari David; Barrentine, Emily M.; Moseley, Samuel H.; Noroozian, Omid; Stevenson, Thomas
2016-01-01
Polycrystalline Nb thin films are extensively used for microwave kinetic inductance detectors (MKIDs) and superconducting transmission line applications. The microwave and mm-wave loss in these films is impacted, in part, by the presence of surface nitrides and oxides. In this study, glancing incidence x-ray diffraction was used to identify the presence of niobium nitride and niobium monoxide surface layers on Nb thin films which had been exposed to chemicals used in standard photolithographic processing. A method of mitigating the presence of ordered niobium monoxide surface layers is presented. Furthermore, we discuss the possibility of using glancing incidence x-ray diffraction as a non-destructive diagnostic tool for evaluating the quality of Nb thin films used in MKIDs and transmission lines. For a given fabrication process, we have both the X-ray diffraction data of the surface chemistry and a measure of the mm-wave and microwave loss, the latter being made in superconducting resonators.
Feasibility of pulse wave velocity estimation from low frame rate US sequences in vivo
NASA Astrophysics Data System (ADS)
Zontak, Maria; Bruce, Matthew; Hippke, Michelle; Schwartz, Alan; O'Donnell, Matthew
2017-03-01
The pulse wave velocity (PWV) is considered one of the most important clinical parameters to evaluate CV risk, vascular adaptation, etc. There has been substantial work attempting to measure the PWV in peripheral vessels using ultrasound (US). This paper presents a fully automatic algorithm for PWV estimation from the human carotid using US sequences acquired with a Logic E9 scanner (modified for RF data capture) and a 9L probe. Our algorithm samples the pressure wave in time by tracking wall displacements over the sequence, and estimates the PWV by calculating the temporal shift between two sampled waves at two distinct locations. Several recent studies have utilized similar ideas along with speckle tracking tools and high frame rate (above 1 KHz) sequences to estimate the PWV. To explore PWV estimation in a more typical clinical setting, we used focused-beam scanning, which yields relatively low frame rates and small fields of view (e.g., 200 Hz for 16.7 mm filed of view). For our application, a 200 Hz frame rate is low. In particular, the sub-frame temporal accuracy required for PWV estimation between locations 16.7 mm apart, ranges from 0.82 of a frame for 4m/s, to 0.33 for 10m/s. When the distance is further reduced (to 0.28 mm between two beams), the sub-frame precision is in parts per thousand (ppt) of the frame (5 ppt for 10m/s). As such, the contributions of our algorithm and this paper are: 1. Ability to work with low frame-rate ( 200Hz) and decreased lateral field of view. 2. Fully automatic segmentation of the wall intima (using raw RF images). 3. Collaborative Speckle Tracking of 2D axial and lateral carotid wall motion. 4. Outlier robust PWV calculation from multiple votes using RANSAC. 5. Algorithm evaluation on volunteers of different ages and health conditions.
NASA Astrophysics Data System (ADS)
Greenwood, William; Clark, Marin; Zekkos, Dimitrios; Von Voigtlander, Jennifer; Bateman, Julie; Lowe, Katherine; Hirose, Mitsuhito; Anderson, Suzanne; Anderson, Robert; Lynch, Jerome
2016-04-01
A field and laboratory experimental study was conducted to assess the influence of weathering on the mechanical properties of basalts in the region of the Kohala volcano on the island of Hawaii. Through the systematic characterization of the weathering profiles developed in different precipitation regimes, we aim to explain the regional pattern of stability of slopes in layered basalts that were observed during the 2006 Mw 6.7 Kiholo Bay earthquake. While deeper weathering profiles on the wet side of the island might be expected to promote more and larger landslides, the distribution of landslides during the Kiholo Bay earthquake did not follow this anticipated trend. Landslide frequency (defined as number of landslides divided by total area) was similar on the steepest slopes (> 50-60) for both the dry and the wet side of the study area suggesting relatively strong ground materials irrespective of weathering. The study location is ideally suited to investigate the role of precipitation, and more broadly of climate, on the mechanical properties of the local rock units because the presence of the Kohala volcano produces a significant precipitation gradient on what are essentially identical basaltic flows. Mean annual precipitation (MAP) varies by more than an order of magnitude, from 200 mm/year on the western side of the volcano to 4000 mm/year in the eastern side. We will present results of measured shear wave velocities using a seismic surface wave methodology. These results were paired with laboratory testing on selected basalt specimens that document the sample-scale shear wave velocity and unconfined compressive strength of the basaltic rocks. Shear wave velocity and unconfined strength of the rocks are correlated and are both significantly lower in weathered rocks near the ground surface than at depth. This weathering-related reduction in shear wave velocity extends to greater depths in areas of high precipitation compared to areas of lower precipitation, as expected, with a pronounced transition occurring at about 1000 mm/yr MAP. We speculate that relatively stiff, sub-horizontal layers that are interbedded with weathered material, may explain the discrepancy between both lower seismic velocities (in the field and the laboratory) and lower unconfined compressive strength, and the interpreted high strength exhibited by the seismic slope response during the Kiholo Bay earthquake. This observation has important consequences on the type of landslides observed in the 2006 earthquake, as well as the landslides that can be expected in future earthquakes.
Long period gratings in multimode optical fibers: application in chemical sensing
NASA Astrophysics Data System (ADS)
Thomas Lee, S.; Dinesh Kumar, R.; Suresh Kumar, P.; Radhakrishnan, P.; Vallabhan, C. P. G.; Nampoori, V. P. N.
2003-09-01
We propose and demonstrate a new technique for evanescent wave chemical sensing by writing long period gratings in a bare multimode plastic clad silica fiber. The sensing length of the present sensor is only 10 mm, but is as sensitive as a conventional unclad evanescent wave sensor having about 100 mm sensing length. The minimum measurable concentration of the sensor reported here is 10 nmol/l and the operating range is more than 4 orders of magnitude. Moreover, the detection is carried out in two independent detection configurations viz., bright field detection scheme that detects the core-mode power and dark field detection scheme that detects the cladding mode power. The use of such a double detection scheme definitely enhances the reliability and accuracy of the results. Furthermore, the cladding of the present fiber need not be removed as done in conventional evanescent wave fiber sensors.
Plunkett, S E; Jonas, R E; Braiman, M S
1997-01-01
We have used miniature planar IR waveguides, consisting of Ge strips 30-50 microm thick and 2 mm wide, as evanescent-wave sensors to detect the mid-(IR) evanescent-wave absorbance spectra of small areas of biomolecular monolayers and multilayers. Examples include picomolar quantities of an integral transmembrane protein (bacteriorhodopsin) and lipid (dimyristoyl phosphatidylcholine). IR bands due to the protein and lipid components of the plasma membrane of individual 1.5-mm-diameter devitellinized Xenopus laevis oocytes, submerged in buffer and sticking to the waveguide surface, were also detected. A significant improvement in sensitivity was observed, as compared to previous sizes and geometries of evanescent-wave sensors (e.g., commercially available internal reflection elements or tapered optical fibers). These measurements suggest the feasibility of using such miniature supported planar IR waveguides to observe structural changes in transmembrane proteins functioning in vivo in single cells. PMID:9336219
A Millimeter-wave Cavity-backed Suspended Substrate Stripline Antenna
NASA Technical Reports Server (NTRS)
Simons, Rainee N.
1999-01-01
Future generation satellite communication systems in near-Earth orbit will operate at frequencies in the higher mm-wave frequency hands. These satellite systems require low-profile, high gain, light weight and low cost antennas for communications to and from Earth as well as for inter-satellite links (ISL). At higher mm-wave frequencies, the conductor loss of conventional microstrip line is high and consequently the feed network loss of patch antenna arrays is also high. The high loss lowers the array efficiency and in addition lowers the G/T ratio in a receiving array. Recently a radial line slot antenna array has been demonstrated to have high gain and efficiency at 60 GHz. In this paper, the design, fabrication and characterization of a V-Band (50-75 GHz) 4 x 4 planar array of cavity backed circular aperture antennas with suspended substrate stripline (SSS) corporate feed is presented.
NASA Astrophysics Data System (ADS)
Qian, Zhengyang; Takezawa, Yoshiki; Shimokawa, Kenji; Kino, Hisashi; Fukushima, Takafumi; Kiyoyama, Koji; Tanaka, Tetsu
2018-04-01
Health monitoring and self-management have become increasingly more important because of health awareness improvement, the aging of population, and other reasons. In general, pulse waves are among the most useful physiological signals that can be used to calculate several parameters such as heart rate and blood pressure for health monitoring and self-management. To realize an automatic and real-time pulse-wave monitoring system that can be used in daily life, we have proposed a trans-nail pulse-wave monitoring system that was placed on the fingernail to detect photoplethysmographic (PPG) signals as pulse waves. In this study, we designed a PPG recording circuit that was composed of a 600 × 600 µm2 photodiode (PD), an LED driver with pulse wave modulation (PWM) and a low-frequency ring oscillator (RING), and a PPG signal readout circuit. The proposed circuit had a very small area of 2.2 × 1.1 mm2 designed with 0.18 µm CMOS technology. The proposed circuit was used to detect pulse waves on the human fingernail in both the reflection and transmission modes. Electrical characteristics of the prototype system were evaluated precisely and PPG waveforms were obtained successfully.
Chiral Domain Structure in Superfluid 3He-A Studied by Magnetic Resonance Imaging
NASA Astrophysics Data System (ADS)
Kasai, J.; Okamoto, Y.; Nishioka, K.; Takagi, T.; Sasaki, Y.
2018-05-01
The existence of a spatially varying texture in superfluid 3He is a direct manifestation of the complex macroscopic wave function. The real space shape of the texture, namely, a macroscopic wave function, has been studied extensively with the help of theoretical modeling but has never been directly observed experimentally with spatial resolution. We have succeeded in visualizing the texture by a specialized magnetic resonance imaging. With this new technology, we have discovered that the macroscopic chiral domains, of which sizes are as large as 1 mm, and corresponding chiral domain walls exist rather stably in 3He - A film at temperatures far below the transition temperature.
NASA Astrophysics Data System (ADS)
Alobaidi, Wissam M.; Nima, Zeid A.; Sandgren, Eric
2018-01-01
Localised surface plasmon (LSP)-like resonance phenomena were simulated in COMSOL Multiphysics™, and the electric field enhancement was evaluated in eight pipe defects using the microwave band from 1.80 to 3.00 GHz and analysed by finite element analysis (FEA). The simulation was carried out, in each defect case, on a pipe that has 762 mm length and 152.4 mm inner diameter, and 12.7 mm pipe wall thickness. Defects were positioned in the middle of the pipe and were named as follows; SD: Square Defect, FCD: fillet corner defect, FD: fillet defect, HCD: half circle defect, TCD: triangle corner defect, TD: triangle defect, ZD: zigzag defect, GD: gear defect. The LSP electric field, and scattering parametric (S21, and S11) waves were evaluated in all cases and found to be strongly dependent on the size and the shape of the defect rather than the pipe and or the medium materials.
A two-layer linear piezoelectric micromotor.
Li, Xiaotian; Ci, Penghong; Liu, Guoxi; Dong, Shuxiang
2015-03-01
A first bending (B1) mode two-layer piezoelectric ultrasonic linear micromotor has been developed for microoptics driving applications. The piezo-vibrator of the micromotor was composed of two small Pb(Zr,Ti)O3 (PZT-5) plates, with overall dimensions and mass of only 2.0 × 2.0 × 5.0 mm(3) and 0.2 g, respectively. The proposed micromotor could operate either in single-phase voltage (standing wave) mode or two-phase voltage (traveling wave) mode to drive a slider via friction force to provide bidirectional linear motion. A large thrust of up to 0.30 N, which corresponds to a high unit volume direct driving force of 15 mN/mm(3), and a linear movement velocity of up to 230 mm/s were obtained under an applied voltage of 80 Vpp at the B1 mode resonance frequency of 174 kHz.
He, Jianpeng; Dixon, Steve; Hill, Samuel; Xu, Ke
2017-01-01
Electromagnetic acoustic transducers (EMATs) are non-contact, ultrasonic transducers that are usually kept within 5 mm from the sample surface to obtain a sufficient signal-to-noise ratio (SNR). One important issue associated with operation on a ferromagnetic plate is that the strong attraction force from the magnet can affect measurements and make scanning difficult. This paper investigates a method to generate fundamental, symmetric Lamb waves on a ferromagnetic plate. A coil-only, low-weight, generation EMAT is designed and investigated, operating at lift-offs of over 5 mm. Another design of an EMAT is investigated using a rectangular magnet with a much higher lift-off than the coil, of up to 19 mm. This results in a much lower force between the EMAT and sample, making scanning the EMAT much easier. PMID:28471377
Wind flow modulation due to variations of the water surface roughness
NASA Astrophysics Data System (ADS)
Shomina, Olga; Ermakov, Stanislav; Kapustin, Ivan; Lazareva, Tatiana
2016-04-01
Air-ocean interaction is a classical problem in atmosphere and ocean physics, which has important geophysical applications related to calculation of vertical and horizontal humidity, aerosol and gas fluxes, development of global climate models and weather forecasts. The structure of wind flow over fixed underlying surfaces, such as forestry, buildings, mountains, is well described, while the interaction between a rough water surface and turbulent wind is far more complicated because of the presence of wind waves with different wavelength and amplitudes and propagating with different velocities and directions. The aim of this study was to investigate experimentally the variability of the wind profile structure due to variations of wave characteristics. The surface roughness variations were produced using a) surfactant films (oleic acid) spread on the water surface and b) mechanically generated waves superimposed on wind waves. The first case is related to oil slicks on sea surface, the second one - to the sea swell, which propagates into zones with lower wind velocities and interacts with wind flow. Laboratory experiments were conducted in the Oval Wind Wave Tank (OWWT) at the Institute of Applied Physics, cross-section of the wind channel is 30 cm x30 cm. Wave amplitude and the spectrum of surface waves were measured by a wire wave gauge, the wind speed was measured using a hot-wire anemometer DISA and a Pitot tube. In the experiments with surfactants, two frequencies of dripping of the oleic acid were studied, so that low concentration films with the elasticity parameters of about 19 mN/m and the high concentration ("thick") films with the elasticity of 34 mN/m were formed. In the experiments with mechanically generated waves (MGW) different regimes were studied with MGW amplitude of 3.4 mm and of 4.4 mm, and with MGW frequencies of 3.3 Hz and 3.7 Hz. It was shown, that: a) the mean velocity of the wind flow in the presence of surfactant and MGW can be described by a logarithmic profile; b) in the presence of a surfactant film an increase of wind speed was revealed; the more elastic films was deployed on the surface - the stronger wind acceleration was detected; c) MGW result in deceleration of wind flow, the larger MGW amplitude the stronger wind flow reduction is; d) the wind deceleration effect is more pronounced for MGW with higher frequency, i.e. for slower propagating MGW. e) experimental dependencies of the logarithmic wind profile characteristics as functions of the rout mean square (RMS) wave height were obtained demonstrating the growth of the wind friction velocity and the roughness coefficient with RMS. The work has been supported by the Russian Foundation of Basic Research (Projects № 14-05-31535, 14-05-00876, 15-35-20992).
Design of a side coupled standing wave accelerating tube for NSTRI e-Linac
NASA Astrophysics Data System (ADS)
Zarei, S.; Abbasi Davani, F.; Lamehi Rachti, M.; Ghasemi, F.
2017-09-01
The design and construction of a 6 MeV electron linear accelerator (e-Linac) was defined in the Institute of Nuclear Science and Technology (NSTRI) for cargo inspection and medical applications. For this accelerator, a side coupled standing wave tube resonant at a frequency of 2998.5 MHZ in π/2 mode was selected. In this article, the authors provide a step-by-step explanation of the process of the design for this tube. The design and simulation of the accelerating and coupling cavities were carried out in five steps; (1) separate design of the accelerating and coupling cavities, (2) design of the coupling aperture between the cavities, (3) design of the entire structure for resonance at the nominal frequency, (4) design of the buncher, and (5) design of the power coupling port. At all design stages, in addition to finding the dimensions of the cavity, the impact of construction tolerances and simulation errors on the electromagnetic parameters were investigated. The values obtained for the coupling coefficient, coupling constant, quality factor and capture efficiency are 2.11, 0.011, 16203 and 36%, respectively. The results of beam dynamics study of the simulated tube in ASTRA have yielded a value of 5.14 π-mm-mrad for the horizontal emittance, 5.06 π-mm-mrad for the vertical emittance, 1.17 mm for the horizontal beam size, 1.16 mm for the vertical beam size and 1090 keV for the energy spread of the output beam.
Alfven Waves in the Solar Corona
NASA Astrophysics Data System (ADS)
Tomczyk, S.; McIntosh, S. W.; Keil, S. L.; Judge, P. G.; Schad, T.; Seeley, D. H.; Edmondson, J.
2007-12-01
We present observations of the coronal intensity, line-of-sight velocity, and linear polarization obtained in the FeXIII 1074.7 nm coronal emission line with the Coronal Multi-channel Polarimeter (CoMP) instrument. Analysis of these observations reveal ubiquitous upward propagating waves with phase speeds of 1-4 Mm/s and trajectories consistent with the direction of the magnetic field inferred from the linear polarization measurements. We can definitively identify these as Alfvén waves. An estimate of the energy carried by the waves that we spatially resolve indicates that they are unable to heat the solar corona, however, unresolved waves may carry sufficient energy.
Large-scale oscillatory calcium waves in the immature cortex.
Garaschuk, O; Linn, J; Eilers, J; Konnerth, A
2000-05-01
Two-photon imaging of large neuronal networks in cortical slices of newborn rats revealed synchronized oscillations in intracellular Ca2+ concentration. These spontaneous Ca2+ waves usually started in the posterior cortex and propagated slowly (2.1 mm per second) toward its anterior end. Ca2+ waves were associated with field-potential changes and required activation of AMPA and NMDA receptors. Although GABAA receptors were not involved in wave initiation, the developmental transition of GABAergic transmission from depolarizing to hyperpolarizing (around postnatal day 7) stopped the oscillatory activity. Thus we identified a type of large-scale Ca2+ wave that may regulate long-distance wiring in the immature cortex.
Arterial compliance probe for local blood pulse wave velocity measurement.
Nabeel, P M; Joseph, Jayaraj; Sivaprakasam, Mohanasankar
2015-08-01
Arterial compliance and vessel wall dynamics are significant in vascular diagnosis. We present the design of arterial compliance probes for measurement of local pulse wave velocity (PWV). Two designs of compliance probe are discussed, viz (a) a magnetic plethysmograph (MPG) based probe, and (b) a photoplethysmograph (PPG) based probe. The ability of the local PWV probes to consistently capture carotid blood pulse waves is verified by in-vivo trials on few volunteers. The probes could reliably perform repeatable measurements of local PWV from carotid artery along small artery sections less than 20 mm. Further, correlation between the measured values of local PWV using probes and various measures of blood pressure (BP) was also investigated. The study indicates that such arterial compliance probes have strong potential in cuff less BP monitoring.
Imaging of acoustic waves induced by excimer laser ablation of the cornea
NASA Astrophysics Data System (ADS)
Rossi, Francesca; Pini, Roberto; Siano, Salvatore; Salimbeni, Renzo
1996-12-01
In this present study a pump-and-probe imaging set up was arranged to image and analyze the evolution of pressure waves induced by ArF ablation of the cornea, during their propagation into the eyeball. In vitro experiments simulating the effects of clinical PRK have been performed by using an artificial model of the human eyeball, composed of a cell filled with hyaluronic acid gel with a sample of freshly excised bovine cornea placed on the gel surface. LAser irradiation was provided at a fluence of 180 mJ/cm2. Irradiation spot diameters were varied in the range 2.0-5.0 mm. Images of the traveling acoustic waves evidenced diffraction effects, related to the diameter of laser spots on the corneal surface.
Pulse-echo NDT of adhesively bonded joints in automotive assemblies.
Titov, Sergey A; Maev, Roman Gr; Bogachenkov, Alexey N
2008-11-01
A new method for the detection of void-disbonds at the interfaces of adhesively bonded joins is considered. Based on a simple plane wave model, the output waveform is presented as a sum of two responses associated with the reflection of the ultrasonic wave at the first metal-adhesive interface and the second metal-adhesive interface, respectively. The strong response produced by the wave reverberating in the first metal sheet is eliminated through comparison between the pulse-echo signal measured at the area under the test and reference waveform recorded for the bare first metal sheet outside of the joint. The developed decomposition algorithm has been applied to the study of steel and aluminum samples having various adhesive layer thicknesses in a range of 0.1-1mm.
The effect of suppressors and muzzle brakes on shock wave strength
NASA Astrophysics Data System (ADS)
Phan, K. C.; Stollery, J. L.
Experimental simulations of a gun blast were performed in the course of an optimization study of shock-wave suppressor and muzzle-brake geometry. A single-spark schlieren system was used to photograph the shock waves emerging from a 32-mm shock tube. The suppressor systems tested with respect to the overpressure level included a perforated tube enclosed in an expansion chamber, a cup-and-box suppressor, and noise-absorbent materials inside a suppressor; high suppression efficiency was observed for the first two. Recoil simulation tests, performed with plain and pyramidal baffles, disk, and cylinder, show that the blast level is generally higher for a more efective muzzle brake. An optimum distance from the muzzle to the brake is suggested to be in the region of one caliber.
Laboratory measurements of the millimeter-wave spectra of calcium isocyanide
NASA Astrophysics Data System (ADS)
Steimle, Timothy C.; Saito, Shuji; Takano, Shuro
1993-06-01
The ground state of CaNC is presently characterized by mm-wave spectroscopy, using a standard Hamiltonian linear molecule model to analyze the spectrum. The resulting spectroscopic parameters were used to predict the transition frequencies and Einstein A-coefficients, which should make possible a quantitative astrophysical search for CaNC.
Controlled cavitation to augment SWL stone comminution: mechanistic insights in vitro.
Duryea, Alexander P; Roberts, William W; Cain, Charles A; Hall, Timothy L
2013-02-01
Stone comminution in shock wave lithotripsy (SWL) has been documented to result from mechanical stresses conferred directly to the stone, as well as the activity of cavitational microbubbles. Studies have demonstrated that the presence of this cavitation activity is crucial for stone subdivision; however, its exact role in the comminution process remains somewhat weakly defined, in part because it is difficult to isolate the cavitational component from the shock waves themselves. In this study, we further explored the importance of cavitation in SWL stone comminution through the use of histotripsy ultrasound therapy. Histotripsy was used to target model stones designed to mimic the mid-range tensile fracture strength of naturally occurring cystine calculi with controlled cavitation at strategic time points in the SWL comminution process. All SWL was applied at a peak positive pressure (p+) of 34 MPa and a peak negative pressure (p-) of 8 MPa; a shock rate of 1 Hz was used. Histotripsy pulses had a p- of 33 MPa and were applied at a pulse repetition frequency (PRF) of 100 Hz. Ten model stones were sonicated in vitro with each of five different treatment schemes: A) 10 min of SWL (600 shocks) with 0.7 s of histotripsy interleaved between successive shocks (totaling to 42 000 pulses); B) 10 min of SWL (600 shocks) followed by 10 min of histotripsy applied in 0.7-s bursts (1 burst per second, totaling to 42 000 pulses); C) 10 min of histotripsy applied in 0.7-s bursts (42 000 pulses) followed by 10 min of SWL (600 shocks); D) 10 min of SWL only (600 shocks); E) 10 min of histotripsy only, applied in 0.7-s bursts (42 000 pulses). Following sonication, debris was collected and sieved through 8-, 6-, 4-, and 2-mm filters. It was found that scheme D, SWL only, generated a broad range of fragment sizes, with an average of 14.9 ± 24.1% of the original stone mass remaining > 8 mm. Scheme E, histotripsy only, eroded the surface of stones to tiny particulate debris that was small enough to pass through the finest filter used in this study (<2 mm), leaving behind a single primary stone piece (>8 mm) with mass 85.1 ± 1.6% of the original following truncated sonication. The combination of SWL and histotripsy (schemes A, B, and C) resulted in a shift in the size distribution toward smaller fragments and complete elimination of debris > 8 mm. When histotripsy-controlled cavitation was applied following SWL (B), the increase in exposed stone surface area afforded by shock wave stone subdivision led to enhanced cavitation erosion. When histotripsy-controlled cavitation was applied before SWL (C), it is likely that stone surface defects induced by cavitation erosion provided sites for crack nucleation and accelerated shock wave stone subdivision. Both of these effects are likely at play in the interleaved therapy (A), although shielding of shock waves by remnant histotripsy microbubble nuclei may have limited the efficacy of this scheme. Nevertheless, these results demonstrate the important role played by cavitation in the stone comminution process, and suggest that the application of controlled cavitation at strategic time points can provide an adjunct to traditional SWL therapy.
Smith, N.; Zhong, P.
2012-01-01
To investigate the roles of lithotripter shock wave (LSW) parameters and cavitation in stone comminution, a series of in vitro fragmentation experiments have been conducted in water and 1,3-butanediol (a cavitation-suppressive fluid) at a variety of acoustic field positions of an electromagnetic shock wave lithotripter. Using field mapping data and integrated parameters averaged over a circular stone holder area (Rh = 7 mm), close logarithmic correlations between the average peak pressure (P+(avg)) incident on the stone (D = 10 mm BegoStone) and comminution efficiency after 500 and 1,000 shocks have been identified. Moreover, the correlations have demonstrated distinctive thresholds in P+(avg) (5.3 MPa and 7.6 MPa for soft and hard stones, respectively), that are required to initiate stone fragmentation independent of surrounding fluid medium and LSW dose. These observations, should they be confirmed using other shock wave lithotripters, may provide an important field parameter (i.e., P+(avg)) to guide appropriate application of SWL in clinics, and facilitate device comparison and design improvements in future lithotripters. PMID:22935690
Smith, N; Zhong, P
2012-10-11
To investigate the roles of lithotripter shock wave (LSW) parameters and cavitation in stone comminution, a series of in vitro fragmentation experiments have been conducted in water and 1,3-butanediol (a cavitation-suppressive fluid) at a variety of acoustic field positions of an electromagnetic shock wave lithotripter. Using field mapping data and integrated parameters averaged over a circular stone holder area (R(h)=7 mm), close logarithmic correlations between the average peak pressure (P(+(avg))) incident on the stone (D=10 mm BegoStone) and comminution efficiency after 500 and 1000 shocks have been identified. Moreover, the correlations have demonstrated distinctive thresholds in P(+(avg)) (5.3 MPa and 7.6 MPa for soft and hard stones, respectively), that are required to initiate stone fragmentation independent of surrounding fluid medium and LSW dose. These observations, should they be confirmed using other shock wave lithotripters, may provide an important field parameter (i.e., P(+(avg))) to guide appropriate application of SWL in clinics, and facilitate device comparison and design improvements in future lithotripters. Copyright © 2012 Elsevier Ltd. All rights reserved.
A Millimetre-Wave Cuboid Solid Immersion Lens with Intensity-Enhanced Amplitude Mask Apodization
NASA Astrophysics Data System (ADS)
Yue, Liyang; Yan, Bing; Monks, James N.; Dhama, Rakesh; Wang, Zengbo; Minin, Oleg V.; Minin, Igor V.
2018-06-01
Photonic jet is a narrow, highly intensive, weak-diverging beam propagating into a background medium and can be produced by a cuboid solid immersion lens (SIL) in both transmission and reflection modes. Amplitude mask apodization is an optical method to further improve the spatial resolution of a SIL imaging system via reduction of waist size of photonic jet, but always leading to intensity loss due to central masking of the incoming plane wave. In this letter, we report a particularly sized millimetre-wave cuboid SIL with the intensity-enhanced amplitude mask apodization for the first time. It is able to simultaneously deliver extra intensity enhancement and waist narrowing to the produced photonic jet. Both numerical simulation and experimental verification of the intensity-enhanced apodization effect are demonstrated using a copper-masked Teflon cuboid SIL with 22-mm side length under radiation of a plane wave with 8-mm wavelength. Peak intensity enhancement and the lateral resolution of the optical system increase by about 36.0% and 36.4% in this approach, respectively.
High-frequency response to millimeter wave irradiation of YBaCuO thin film and ceramic
NASA Astrophysics Data System (ADS)
Velichko, A. V.; Cherpak, N. T.; Izhyk, E. V.; Kirichenko, A. Ya.; Chukanova, I. N.
1997-02-01
Microwave (35 GHz) and radiowave (9 MHz) responses of an YBaCuO thin film and a ceramic to millimeter (mm) wave irradiation (31.5 GHz) have been studied by means of a quasioptical dielectric resonator with whispering gallery modes and an inductive technique at micro- and radiowaves, respectively. The responses are shown to have a mixed nature including a sufficiently strong non-bolometric component. Relaxation of the surface resistance in time after the irradiation removal obeys the logarithmic law implying the nucleation and flux creep of vortices induced by the irradiation is a mechanism of the response at temperatures 3-10 K below the critical temperature Tc. Dependence of the microwave surface resistance Rsmw on the mm wave pump amplitude Hω is well described by Halbritter's theory of vortex motion inside weak links. A correlation between dependences of the radiowave (rw) response on Hω with that of Rsmw has been found. Thus the mechanism of rw-response is believed to arise from intergranular Josephson couplings. The latter conclusion is further confirmed by a comparison of the pump power dependence of the rw-response with that of conventional DC-response found for granular HTSC in other recent experiments on the response to the subgap radiation.
Detection of FUS induced lesions by MR-elastography
NASA Astrophysics Data System (ADS)
Jenne, Jürgen W.; Divkovic, Gabriela; Siegler, Peter
2005-03-01
MRI (Magnetic Resonance Imaging) has proven to be an exact and safe method to guide FUS (Focused ultrasound surgery) therapy. Besides its excellent soft tissue contrast, important for a precise treatment planning, MRI allows fast and reliable measurement of temperature changes caused by FUS application. In this study we compare standard MR-imaging parameters (relaxation times, spin density) with MR measured tissue elasticity in order to differentiate between FUS induced thermal lesions and normal tissue in vitro. In addition we tried to observe FUS induced shear waves by dynamic MRE. FUS was performed with an MRI compatible 1.7 MHz fixed focus transducer (NA 0.44; f'= 68 mm). With increasing acoustic power (30-70 W) the difference in relaxation times T1, T2 and spin density between normal and lesioned tissue also increased. We measured values in the range 5% to 24%. The difference in tissue strain had a value of 23% at 30 W and was nearly constant (52-61%) at higher FUS power. Compared with standard MRI parameters MRE showed a clearly higher sensitivity to detect FUS induced lesions. With our experimental setup it was possible to image FUS induced shear waves. The measured wave length at 400Hz repetition rate was 7 mm. However, further experiments are necessary to utilize the potential of MRE in practice.
Transurethral prostate magnetic resonance elastography: prospective imaging requirements.
Arani, Arvin; Plewes, Donald; Chopra, Rajiv
2011-02-01
Tissue stiffness is known to undergo alterations when affected by prostate cancer and may serve as an indicator of the disease. Stiffness measurements can be made with magnetic resonance elastography performed using a transurethral actuator to generate shear waves in the prostate gland. The goal of this study was to help determine the imaging requirements of transurethral magnetic resonance elastography and to evaluate whether the spatial and stiffness resolution of this technique overlapped with the requirements for prostate cancer detection. Through the use of prostate-mimicking gelatin phantoms, frequencies of at least 400 Hz were necessary to obtain accurate stiffness measurements of 10 mm diameter inclusions, but the detection of inclusions with diameters as small as 4.75 mm was possible at 200 Hz. The shear wave attenuation coefficient was measured in vivo in the canine prostate gland, and was used to predict the detectable penetration depth of shear waves in prostate tissue. These results suggested that frequencies below 200 Hz could propagate to the prostate boundary with a signal to noise ratio (SNR) of 60 and an actuator capable of producing 60 μm displacements. These requirements are achievable with current imaging and actuator technologies, and motivate further investigation of magnetic resonance elastography for the targeting of prostate cancer. Copyright © 2010 Wiley-Liss, Inc.
NASA Astrophysics Data System (ADS)
Lanuru, M.; Samad, W.; Amri, K.; Priosambodo, D.
2018-05-01
Small islands are vulnerable to long-term natural disasters like coastal erosion due to their size and topography. Barrang Caddi is one the small island in the Spermonde Archipelago (South Sulawesi) that encountered serious coastal erosion. Several attempts have been done by the relevant parties like by building a wave breaker to prevent erosion. But in fact some parts of the island are still eroded. A comprehensive oceanographic study of the wave climate and coastal processes at work to delineate the factors responsible for shoreline chance and to identify the location that need protection is needed. In this study, physical oceanographic data including waves, currents, tide, bathymetry, sediment characteristics and sediment transport were collected in the Barrang Caddi Island to analyze the factors responsible for shoreline chance (erosion) in the island. Results of the study showed that tide in the study site is mixed tide, predominantly semidiurnal with tidal range of 118 cm. Current measurements using a electromagnetic current meter revealed that current velocities at the study site were relatively low and vary spatially and temporally with magnitude of 0.02 – 0.58 m/s. Under normal conditions (no storms) the significant wave height (H 1/3) varied from 0.04 to 0.20 m. The wave height decreases from the fore reef to the reef flat due to the presence of coral reefs that reduce wave energy (wave height). Sediments were dominated by biogenic sand with grain diameter of 0.38 – 1.04 mm. Island erosion analysis showed that wave action was a main factor that responsible for shoreline chance (erosion) at the island. Current velocity alone with average of 0.19 m/s was not strong enough to move (erode) sediments at the island.
Shock wave-enhanced neovascularization at the tendon-bone junction: an experiment in dogs.
Wang, Ching-Jen; Huang, Hsuan-Ying; Pai, Chun-Hwan
2002-01-01
The purpose of the research was to study the phenomenon of neovascularization at the Achilles tendon-bone junction after low-energy shock wave application. The study was performed on eight mongrel dogs. The control specimens were obtained from the medial one-third of the right Achilles tendon-bone unit before shock wave application. Low-energy shock waves of 1000 impulses at 14 kV (equivalent to 0.18 mJ/mm2 energy flux density) were applied to the right Achilles bone-tendon junction. Biopsies were taken from the middle one-third of the Achilles tendon-bone junction at 4 weeks and from the lateral one-third at 8 weeks, respectively, after shock wave application. The features of microscopic examination included the number of new capillaries and muscularized vessels, the presence and arrangements of myofibroblasts, and the changes in bone. New capillary and muscularized vessels were seen in the study specimens which were obtained in 4 weeks and in 8 weeks after shock wave application, but none were seen in the control specimens before shock wave application. There was a considerable geographic variation in the number of new vessels within the same specimen. Myofibroblasts were not seen in the control specimens. Myofibroblasts with haphazard appearance and intermediate orientation fibers were seen in all study specimens obtained at 4 weeks and predominantly intermediate orientation myofibroblast fibers at 8 weeks. There were no changes in bone matrix, osteocyte activity, and vascularization within the bone. Two pathologists reviewed each specimen and concurrence was achieved in all cases. The results of the study suggested that low-energy shock wave enhanced the phenomenon of neovascularization at the bone-tendon junction in dogs.
Simulation of blast-induced early-time intracranial wave physics leading to traumatic brain injury.
Taylor, Paul A; Ford, Corey C
2009-06-01
The objective of this modeling and simulation study was to establish the role of stress wave interactions in the genesis of traumatic brain injury (TBI) from exposure to explosive blast. A high resolution (1 mm3 voxels) five material model of the human head was created by segmentation of color cryosections from the Visible Human Female data set. Tissue material properties were assigned from literature values. The model was inserted into the shock physics wave code, CTH, and subjected to a simulated blast wave of 1.3 MPa (13 bars) peak pressure from anterior, posterior, and lateral directions. Three-dimensional plots of maximum pressure, volumetric tension, and deviatoric (shear) stress demonstrated significant differences related to the incident blast geometry. In particular, the calculations revealed focal brain regions of elevated pressure and deviatoric stress within the first 2 ms of blast exposure. Calculated maximum levels of 15 KPa deviatoric, 3.3 MPa pressure, and 0.8 MPa volumetric tension were observed before the onset of significant head accelerations. Over a 2 ms time course, the head model moved only 1 mm in response to the blast loading. Doubling the blast strength changed the resulting intracranial stress magnitudes but not their distribution. We conclude that stress localization, due to early-time wave interactions, may contribute to the development of multifocal axonal injury underlying TBI. We propose that a contribution to traumatic brain injury from blast exposure, and most likely blunt impact, can occur on a time scale shorter than previous model predictions and before the onset of linear or rotational accelerations traditionally associated with the development of TBI.
Innovations in shock wave lithotripsy technology: updates in experimental studies.
Zhou, Yufeng; Cocks, Franklin H; Preminger, Glenn M; Zhong, Pei
2004-11-01
We developed innovations in shock wave lithotripsy (SWL) technology. Two technical upgrades were implemented in an original unmodified HM-3 lithotriptor (Dornier Medical Systems, Inc., Kennesaw, Georgia). First, a single unit ellipsoidal reflector insert was used to modify the profile of lithotriptor shock wave (LSW) to decrease the propensity of tissue injury in SWL. Second, a piezoelectric annular array (PEAA) generator (f = 230 kHz and F = 150 mm) was used to produce an auxiliary shock wave of approximately 13 MPa in peak pressure (at 4 kV output voltage) to intensify the collapse of LSW induced bubbles near the target stone for improved comminution efficiency. Consistent rupture of a vessel phantom made of single cellulose hollow fiber (i.d. = 0.2 mm) was produced after 30 shocks by the original HM-3 reflector at 20 kV. In comparison no vessel rupture could be produced after 200 shocks using the upgraded reflector at 22 kV or the PEAA generator at 4 kV. Using cylindrical BegoStone phantoms (Bego USA, Smithfield, Rhode Island) stone comminution efficiencies (mean +/- sd) after 1,500 shocks produced by the original and upgraded HM-3 reflectors, and the combined PEAA/upgraded HM-3 system, were 81.3% +/- 3.5%, 90.1% +/- 4.3% and 95.2% +/- 3.3%, respectively (p<0.05). Optimization of the pulse profile and sequence of LSW can significantly improve stone comminution while simultaneously decreasing the propensity of tissue injury during in vitro SWL. This novel concept and associated technologies may be used to upgrade other existing lithotriptors and to design new shock wave lithotriptors for improved performance and safety.
Li, Ronny X.; Qaqish, William; Konofagou, Elisa. E.
2015-01-01
The propagation behavior of the arterial pulse wave may provide valuable diagnostic information for cardiovascular pathology. Pulse Wave Imaging (PWI) is a noninvasive, ultrasound imaging-based technique capable of mapping multiple wall motion waveforms along a short arterial segment over a single cardiac cycle, allowing for the regional pulse wave velocity (PWV) and propagation uniformity to be evaluated. The purpose of this study was to improve the clinical utility of PWI using a conventional ultrasound system. The tradeoff between PWI spatial and temporal resolution was evaluated using an ex vivo canine aorta (n = 2) setup to assess the effects of varying image acquisition and signal processing parameters on the measurement of the PWV and the pulse wave propagation uniformity r2. PWI was also performed on the carotid arteries and abdominal aortas of 10 healthy volunteers (24.8 ± 3.3 y.o.) to determine the waveform tracking feature that would yield the most precise PWV measurements and highest r2 values in vivo. The ex vivo results indicated that the highest precision for measuring PWVs ~ 2.5 – 3.5 m/s was achieved using 24–48 scan lines within a 38 mm image plane width (i.e. 0.63 – 1.26 lines/mm). The in vivo results indicated that tracking the 50% upstroke of the waveform would consistently yield the most precise PWV measurements and minimize the error in the propagation uniformity measurement. Such findings may help establish the optimal image acquisition and signal processing parameters that may improve the reliability of PWI as a clinical measurement tool. PMID:26640603
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ford, Corey C.; Taylor, Paul Allen
The objective of this modeling and simulation study was to establish the role of stress wave interactions in the genesis of traumatic brain injury (TBI) from exposure to explosive blast. A high resolution (1 mm{sup 3} voxels), 5 material model of the human head was created by segmentation of color cryosections from the Visible Human Female dataset. Tissue material properties were assigned from literature values. The model was inserted into the shock physics wave code, CTH, and subjected to a simulated blast wave of 1.3 MPa (13 bars) peak pressure from anterior, posterior and lateral directions. Three dimensional plots ofmore » maximum pressure, volumetric tension, and deviatoric (shear) stress demonstrated significant differences related to the incident blast geometry. In particular, the calculations revealed focal brain regions of elevated pressure and deviatoric (shear) stress within the first 2 milliseconds of blast exposure. Calculated maximum levels of 15 KPa deviatoric, 3.3 MPa pressure, and 0.8 MPa volumetric tension were observed before the onset of significant head accelerations. Over a 2 msec time course, the head model moved only 1 mm in response to the blast loading. Doubling the blast strength changed the resulting intracranial stress magnitudes but not their distribution. We conclude that stress localization, due to early time wave interactions, may contribute to the development of multifocal axonal injury underlying TBI. We propose that a contribution to traumatic brain injury from blast exposure, and most likely blunt impact, can occur on a time scale shorter than previous model predictions and before the onset of linear or rotational accelerations traditionally associated with the development of TBI.« less
Stone, Jeremy; Mor-Avi, Victor; Ardelt, Agnieszka; Lang, Roberto M
2018-01-01
Transient, symmetric, and deep inverted electrocardiogram (ECG) T waves in the setting of stroke, commonly referred to as cerebral T waves, are rare, and the underlying mechanism is unclear. Our study aimed to test the hypothesis that cerebral T waves are associated with transient cardiac dysfunction. This retrospective study included 800 patients admitted with the primary diagnosis of hemorrhagic or ischemic stroke. ECGs were examined for cerebral T waves, defined as T-wave inversion of ≥5 mm depth in ≥4 contiguous precordial leads. Echocardiograms of those meeting these criteria were examined for the presence of left ventricular (LV) wall motion abnormalities. Follow-up evaluation included both ECG and echocardiogram. Of the 800 patients, 17 had cerebral T waves on ECG (2.1%). All 17 patients had ischemic strokes, of which 11 were in the middle cerebral artery distribution (65%), and 2 were cerebellar (12%), whereas the remaining 4 involved other locations. Follow-up ECG showed resolution of the T-wave changes in all 17 patients. Of these patients, 14 (82%) had normal wall motion, and 3 had transient wall motion abnormalities (18%). Two of these patients had Takotsubo-like cardiomyopathy with apical ballooning, and the third had globally reduced LV function. Coronary angiography showed no significant disease to explain the LV dysfunction. In summary, in our cohort of patients with acute stroke, cerebral T waves were rare and occurred only in ischemic stroke. Eighteen percent of patients with cerebral T waves had significant transient wall motion abnormalities. Patients with stroke with cerebral T waves, especially in those with ischemic strokes, should be assessed for cardiac dysfunction. Copyright © 2017 Elsevier Inc. All rights reserved.
Goertz, O; von der Lohe, L; Lauer, H; Khosrawipour, T; Ring, A; Daigeler, A; Lehnhardt, M; Kolbenschlag, J
2014-11-01
Burn wounds remain a challenge due to subsequent wound infection and septicemia, which can be prevented by acceleration of wound healing. The aim of the study was to analyze microcirculation and leukocyte endothelium interaction with particular focus on angiogenesis after full-thickness burn using three different repetitions of low energy shock waves. Full-thickness burns were inflicted to the ears of hairless mice (n=44; area: 1.6±0.05 mm2 (mean±SEM)). Mice were randomized into four groups: the control group received a burn injury but no shock waves; group A received ESWA (0.03 mJ/mm2) on day one after burn injury; group B received shock waves on day one and day three after burn injury; group C ESWA on day one, three and seven after burn injury. Intravital fluorescent microscopy was used to assess microcirculatory parameters, angiogenesis and leukocyte interaction. Values were obtained before burn (baseline value) immediately after and on days 1, 3, 7 and 12 after burn. Shock-wave treated groups showed significantly accelerated angiogenesis compared to the control group. The non-perfused area (NPA) is regarded as a parameter for angiogenesis and showed the following data on day 12 2.7±0.4% (group A, p=0.001), 1.4±0.5% (group B, p<0.001), 1.0±0.3% (group C, p<0.001), 6.1±0.9% (control group). Edema formation is positively correlated with the number of shock wave applications: day 12: group A: 173.2±9.8%, group B: 184.2±6.6%, group C: 201.1±6.9%, p=0.009 vs. control: 162.3±8.7% (all data: mean±SEM). According to our data shock waves positively impact the wound healing process following burn injury. Angiogenesis showed significantly improved activity after shock wave application. In all three treatment groups angiogenesis was higher compared to the control group. Within the ESWA groups, double applications showed better results than single application and three applications showed better results than single or double applications. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.
Skerl, K; Vinnicombe, S; Giannotti, E; Thomson, K; Evans, A
2015-12-01
To evaluate the influence of the region of interest (ROI) size and lesion diameter on the diagnostic performance of 2D shear wave elastography (SWE) of solid breast lesions. A study group of 206 consecutive patients (age range 21-92 years) with 210 solid breast lesions (70 benign, 140 malignant) who underwent core biopsy or surgical excision was evaluated. Lesions were divided into small (diameter <15 mm, n=112) and large lesions (diameter ≥15 mm, n=98). An ROI with a diameter of 1, 2, and 3 mm was positioned over the stiffest part of the lesion. The maximum elasticity (Emax), mean elasticity (Emean) and standard deviation (SD) for each ROI size were compared to the pathological outcome. Statistical analysis was undertaken using the chi-square test and receiver operating characteristic (ROC) analysis. The ROI size used has a significant impact on the performance of Emean and SD but not on Emax. Youden's indices show a correlation with the ROI size and lesion size: generally, the benign/malignant threshold is lower with increasing ROI size but higher with increasing lesion size. No single SWE parameter has superior performance. Lesion size and ROI size influence diagnostic performance. Copyright © 2015. Published by Elsevier Ltd.
Attributing Tropical Cyclogenesis to Equatorial Waves in the Western North Pacific
NASA Technical Reports Server (NTRS)
Schreck, Carl J., III; Molinari, John; Mohr, Karen I.
2009-01-01
The direct influences of equatorial waves on the genesis of tropical cyclones are evaluated. Tropical cyclogenesis is attributed to an equatorial wave when the filtered rainfall anomaly exceeds a threshold value at the genesis location. For an attribution threshold of 3 mm/day, 51% of warm season western North Pacific tropical cyclones are attributed to tropical depression (TD)-type disturbances, 29% to equatorial Rossby waves, 26% to mixed Rossby-Gravity waves, 23% to Kelvin waves, 13% to the Madden-Julian oscillation (MJO), and 19% are not attributed to any equatorial wave. The fraction of tropical cyclones attributed to TD-type disturbances is consistent with previous findings. Past studies have also demonstrated that the MJO significantly modulates tropical cyclogenesis, but fewer storms are attributed to the MJO than any other wave type. This disparity arises from the difference between attribution and modulation. The MJO produces broad regions of favorable conditions for cyclogenesis, but the MJO alone might not determine when and where a storm will develop within these regions. Tropical cyclones contribute less than 17% of the power in any portion of the equatorial wave spectrum because tropical cyclones are relatively uncommon equatorward of 15deg latitude. In regions where they are active, however, tropical cyclones can contribute more than 20% of the warm season rainfall and up to 50% of the total variance. Tropical cyclone-related anomalies can significantly contaminate wave-filtered precipitation at the location of genesis. To mitigate this effect, the tropical cyclone-related rainfall anomalies were removed before filtering in this study.
Air transparent soundproof window
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Sang-Hoon, E-mail: shkim@mmu.ac.kr; Lee, Seong-Hyun
2014-11-15
A soundproof window or wall which is transparent to airflow is presented. The design is based on two wave theories: the theory of diffraction and the theory of acoustic metamaterials. It consists of a three-dimensional array of strong diffraction-type resonators with many holes centered on each individual resonator. The negative effective bulk modulus of the resonators produces evanescent wave, and at the same time the air holes with subwavelength diameter existed on the surfaces of the window for macroscopic air ventilation. The acoustic performance levels of two soundproof windows with air holes of 20mm and 50mm diameters were measured. Themore » sound level was reduced by about 30 - 35dB in the frequency range of 400 - 5,000Hz with the 20mm window, and by about 20 - 35dB in the frequency range of 700 - 2,200Hz with the 50mm window. Multi stop-band was created by the multi-layers of the window. The attenuation length or the thickness of the window was limited by background noise. The effectiveness of the soundproof window with airflow was demonstrated by a real installation.« less
NASA Technical Reports Server (NTRS)
Duvall, Thomas L.; Hanasoge, Shravan M.
2012-01-01
With large separations (10-24 deg heliocentric), it has proven possible to cleanly separate the horizontal and vertical components of supergranular flow with time-distance helioseismology. These measurements require very broad filters in the k-$\\omega$ power spectrum as apparently supergranulation scatters waves over a large area of the power spectrum. By picking locations of supergranulation as peaks in the horizontal divergence signal derived from f-mode waves, it is possible to simultaneously obtain average properties of supergranules and a high signal/noise ratio by averaging over many cells. By comparing ray-theory forward modeling with HMI measurements, an average supergranule model with a peak upflow of 240 m/s at cell center at a depth of 2.3 Mm and a peak horizontal outflow of 700 m/s at a depth of 1.6 Mm. This upflow is a factor of 20 larger than the measured photospheric upflow. These results may not be consistent with earlier measurements using much shorter separations (<5 deg heliocentric). With a 30 Mm horizontal extent and a few Mm in depth, the cells might be characterized as thick pancakes.
NASA Astrophysics Data System (ADS)
Tanigawa, Hiroshi; Seno, Hiroaki; Watanabe, Yoshiaki; Nakajima, Koshiro
1998-05-01
A nondestructive inspection method to estimate the contact condition of soil on the surface of an underground pipe, utilizing the resonance of a transverse Lamb wave circulating along the pipe wall is proposed.The Q factor of the resonance is considered and measured under some contact conditions by sweeping the vibrating frequency in a 150-mm-inner diameter Fiberglass Reinforced Plastic Mortar (FRPM) pipe. It is confirmed that the Q factor shows a clear response to the change in the contact conditions. For example, the Q factor is 8.4 when the pipe is in ideal contact with the soil plane and goes up to 19.2 when a 100-mm-diameter void is located at the contact surface of the soil.The spatial resolution of the proposed inspection method is also measured by moving the sensing point along the direction of laying the length of the pipe into a 85-mm-diameter void. The resolution of the proposed method is estimated at about 50 mm.
A rod type linear ultrasonic motor utilizing longitudinal traveling waves: proof of concept
NASA Astrophysics Data System (ADS)
Wang, Liang; Wielert, Tim; Twiefel, Jens; Jin, Jiamei; Wallaschek, Jörg
2017-08-01
This paper proposes a non-resonant linear ultrasonic motor utilizing longitudinal traveling waves. The longitudinal traveling waves in the rod type stator are generated by inducing longitudinal vibrations at one end of the waveguide and eliminating reflections at the opposite end by a passive damper. Considering the Poisson’s effect, the stator surface points move on elliptic trajectories and the slider is driven forward by friction. In contrast to many other flexural traveling wave linear ultrasonic motors, the driving direction of the proposed motor is identical to the wave propagation direction. The feasibility of the motor concept is demonstrated theoretically and experimentally. First, the design and operation principle of the motor are presented in detail. Then, the stator is modeled utilizing the transfer matrix method and verified by experimental studies. In addition, experimental parameter studies are carried out to identify the motor characteristics. Finally, the performance of the proposed motor is investigated. Overall, the results indicate very dynamic drive characteristics. The motor prototype achieves a maximum mean velocity of 115 mm s-1 and a maximum load of 0.25 N. Thereby, the start-up and shutdown times from the maximum speed are lower than 5 ms.
NASA Astrophysics Data System (ADS)
Jia, Jing; Zhang, Yu; Han, Qingbang; Jing, Xueping
2017-10-01
The research focuses on study the influence of truncations on the dispersion of wedge waves propagating along cylinder wedge with different truncations by using the laser ultrasound technique. The wedge waveguide models with different truncations were built by using finite element method (FEM). The dispersion curves were obtained by using 2D Fourier transformation method. Multiple mode wedge waves were observed, which was well agreed with the results estimated from Lagasse's empirical formula. We established cylinder wedge with radius of 3mm, 20° and 60°angle, with 0μm, 5μm, 10μm, 20μm, 30μm, 40μm, and 50μm truncations, respectively. It was found that non-ideal wedge tip caused abnormal dispersion of the mode of cylinder wedge, the modes of 20° cylinder wedge presents the characteristics of guide waves which propagating along hollow cylinder as the truncation increasing. Meanwhile, the modes of 60° cylinder wedge with truncations appears the characteristics of guide waves propagating along hollow cylinder, and its mode are observed clearly. The study can be used to evaluate and detect wedge structure.
Foda, Khaled; Abdeldaeim, Hussein; Youssif, Mohamed; Assem, Akram
2013-11-01
To define the parameters that accompanied a successful extracorporeal shock wave lithotripsy (ESWL), namely the number of shock waves (SWs), expulsion time (ET), mean stone density (MSD), and the skin-to-stone distance (SSD). A total of 368 patients diagnosed with renal calculi using noncontrast computerized tomography had their MSD, diameter, and SSD recorded. All patients were treated using a Siemens lithotripter. ESWL success meant a stone-free status or presence of residual fragments <3 mm, ET was the time in days for the successful clearance of stone fragments. Correlation was performed between the stone characteristics, number of SWs, and ET. Two multiple regression analysis models defined the number of SWs and ET. Two receiver operating characteristic curves plotted the best MSD cutoff value and optimum SSD for a successful ESWL. Three hundred one patients were ESWL successes. A significant positive correlation was elicited between number of SWs and stone diameter, density and SSD; between ET and stone diameter and density. Multiple regressions concluded 2 equations: Number of SWs = 265.108 + 5.103 x1 + 22.39 x2 + 10.931 x3 ET (days) = -10.85 + 0.031 x1 + 2.11 x2 x1 = stone density (Hounsfield unit [HUs]), x2 = stone diameter (mm), and x3 = SSD (mm). Receiver operating characteristic curves demonstrated a cutoff value of ≤ 934 HUs with 94.4% sensitivity and 66.7% specificity and P = .0211. The SSD curve showed that a distance ≤ 99 mm was 85.7% sensitive, 87.5% specific, P <.0001. Stone disintegration is not recommended if MSD is >934 HUs and SSD >99 mm. The required number of SWs and the expected ET can be anticipated. Copyright © 2013 Elsevier Inc. All rights reserved.
Koutroumbas, Georgios; Georgianos, Panagiotis I.; Sarafidis, Pantelis A.; Protogerou, Athanase; Karpetas, Antonios; Vakianis, Pantelis; Raptis, Vassilios; Liakopoulos, Vassilios; Panagoutsos, Stylianos; Syrganis, Christos; Passadakis, Ploumis
2015-01-01
Background Increased arterial stiffness and aortic blood pressure (BP) are independent predictors of cardiovascular outcomes in end-stage renal disease. The 3-day interdialytic interval is associated with elevated risk of cardiovascular morbidity and mortality in haemodialysis. This study investigated differences in ambulatory aortic BP and arterial stiffness between the second and third day of the long interdialytic interval. Methods Ambulatory BP monitoring with Mobil-O-Graph monitor (IEM, Stolberg, Germany) was performed in 55 haemodialysis patients during a 3-day interval. Mobil-O-Graph records oscillometric brachial BP and pulse waves and calculates aortic BP and augmentation index (AIx) as measure of wave reflections, and pulse wave velocity (PWV) as measure of arterial stiffness. Results Ambulatory aortic systolic blood pressure (SBP) and diastolic blood pressure (DBP) were higher during the third versus second interdialytic day (123.6 ± 17.0 versus 118.5 ± 17.1 mmHg, P < 0.001; 81.5 ± 11.8 versus 78 ± 11.9 mmHg, P < 0.001, respectively). Similar differences were noted for brachial BP. Ambulatory AIx and PWV were also significantly increased during the third versus second day (30.5 ± 9.9 versus 28.8 ± 9.9%, P < 0.05; 9.6 ± 2.3 versus 9.4 ± 2.3 m/s, P < 0.001, respectively). Differences between Days 2 and 3 remained significant when day-time and night-time periods were compared separately. Aortic SBP and DBP, AIx and PWV showed gradual increases from the end of dialysis session onwards. Interdialytic weight gain was a strong determinant of the increase in the above parameters. Conclusions This study showed significantly higher ambulatory aortic BP, AIx and PWV levels during the third compared with the second interdialytic day. These findings support a novel pathway for increased cardiovascular risk during the third interdialytic day in haemodialysis. PMID:25920919
Millimeter-Wave Polarimeters Using Kinetic Inductance Detectors for TolTEC and Beyond
NASA Astrophysics Data System (ADS)
Austermann, J. E.; Beall, J. A.; Bryan, S. A.; Dober, B.; Gao, J.; Hilton, G.; Hubmayr, J.; Mauskopf, P.; McKenney, C. M.; Simon, S. M.; Ullom, J. N.; Vissers, M. R.; Wilson, G. W.
2018-05-01
Microwave kinetic inductance detectors (MKIDs) provide a compelling path forward to the large-format polarimeter, imaging, and spectrometer arrays needed for next-generation experiments in millimeter-wave cosmology and astronomy. We describe the development of feedhorn-coupled MKID detectors for the TolTEC millimeter-wave imaging polarimeter being constructed for the 50-m Large Millimeter Telescope (LMT). Observations with TolTEC are planned to begin in early 2019. TolTEC will comprise ˜ 7000 polarization-sensitive MKIDs and will represent the first MKID arrays fabricated and deployed on monolithic 150 mm diameter silicon wafers—a critical step toward future large-scale experiments with over 10^5 detectors. TolTEC will operate in observational bands at 1.1, 1.4, and 2.0 mm and will use dichroic filters to define a physically independent focal plane for each passband, thus allowing the polarimeters to use simple, direct-absorption inductive structures that are impedance matched to incident radiation. This work is part of a larger program at NIST-Boulder to develop MKID-based detector technologies for use over a wide range of photon energies spanning millimeter-waves to X-rays. We present the detailed pixel layout and describe the methods, tools, and flexible design parameters that allow this solution to be optimized for use anywhere in the millimeter and sub-millimeter bands. We also present measurements of prototype devices operating in the 1.1 mm band and compare the observed optical performance to that predicted from models and simulations.
Photonic metamaterials: a new class of materials for manipulating light waves
Iwanaga, Masanobu
2012-01-01
A decade of research on metamaterials (MMs) has yielded great progress in artificial electromagnetic materials in a wide frequency range from microwave to optical frequencies. This review outlines the achievements in photonic MMs that can efficiently manipulate light waves from near-ultraviolet to near-infrared in subwavelength dimensions. One of the key concepts of MMs is effective refractive index, realizing values that have not been obtained in ordinary solid materials. In addition to the high and low refractive indices, negative refractive indices have been reported in some photonic MMs. In anisotropic photonic MMs of high-contrast refractive indices, the polarization and phase of plane light waves were efficiently transformed in a well-designed manner, enabling remarkable miniaturization of linear optical devices such as polarizers, wave plates and circular dichroic devices. Another feature of photonic MMs is the possibility of unusual light propagation, paving the way for a new subfield of transfer optics. MM lenses having super-resolution and cloaking effects were introduced by exploiting novel light-propagating modes. Here, we present a new approach to describing photonic MMs definitely by resolving the electromagnetic eigenmodes. Two representative photonic MMs are addressed: the so-called fishnet MM slabs, which are known to have effective negative refractive index, and a three-dimensional MM based on a multilayer of a metal and an insulator. In these photonic MMs, we elucidate the underlying eigenmodes that induce unusual light propagations. Based on the progress of photonic MMs, the future potential and direction are discussed. PMID:27877512
Arterial wave reflection and subclinical atherosclerosis in rheumatoid arthritis.
Gunter, Sule; Robinson, Chanel; Woodiwiss, Angela J; Norton, Gavin R; Hsu, Hon-Chun; Solomon, Ahmed; Tsang, Linda; Millen, Aletta M E; Dessein, Patrick H
2018-01-01
Atherosclerotic cardiovascular disease risk is increased in rheumatoid arthritis (RA). Wave reflection occurs at arterial branching points, which are particularly prone to atherosclerosis. We explored the relationship of wave reflection with atherosclerosis in RA. One hundred and sixty three RA patients (110 white, 31 Asian, 17 black and 5 of mixed ancestry) without cardiovascular disease participated. Arterial stiffness, wave reflection, pressure pulsatility, plaque in the extracranial carotid artery tree and the mean of the left and right common carotid arteries intima-thickness were determined. Associations were identified in multivariable regression models. One SD increase in reflected wave pressure (OR (95% CI) = 2.54 (1.41-4.44), p=0.001), reflection magnitude (OR (95% CI) = 1.84 (1.17-2.89), p=0.008), central pulse pressure (OR (95% CI) = 1.89 (1.12-3.22), p=0.02) and peripheral pulse pressure (OR (95% CI) = 2.09 (1.23-3.57), p=0.007) were associated with plaque. The association of wave reflection with plaque was independent of arterial stiffness and pressure pulsatility, and was present in both hypertensive and normotensive RA patients. In receiver operator characteristic curve analysis, the optimal cutoff value for reflected wave pressure in predicting plaque presence was 25 mmHg with a sensitivity, specificity, positive predictive value and negative predictive value of 45.2%, 89.3%, 78.6% and 66.2%, respectively; a reflected wave pressure of >25 mmHg was associated with plaque in univariate and adjusted analysis (p<0.0001 for both). Arterial function was not independently related to carotid intima-media thickness. Consideration and therapeutic targeting of wave reflection may improve cardiovascular disease prevention in RA.
Heusch, Philipp; Wittsack, Hans-Jörg; Kröpil, Patric; Blondin, Dirk; Quentin, Michael; Klasen, Janina; Pentang, Gael; Antoch, Gerald; Lanzman, Rotem S
2013-01-01
To evaluate the impact of renal blood flow on apparent diffusion coefficients (ADC) and fractional anisotropy (FA) using time-resolved electrocardiogram (ECG)-triggered diffusion-tensor imaging (DTI) of the human kidneys. DTI was performed in eight healthy volunteers (mean age 29.1 ± 3.2) using a single slice coronal echoplanar imaging (EPI) sequence (3 b-values: 0, 50, and 300 s/mm(2)) at the timepoint of minimum (20 msec after R wave) and maximum renal blood flow (200 msec after R wave) at 3T. Following 2D motion correction, region of interest (ROI)-based analysis of cortical and medullary ADC- and FA-values was performed. ADC-values of the renal cortex at maximum blood flow (2.6 ± 0.19 × 10(-3) mm(2)/s) were significantly higher than at minimum blood flow (2.2 ± 0.11 × 10(-3) mm(2)/s) (P < 0.001), while medullary ADC-values did not differ significantly (maximum blood flow: 2.2 ± 0.18 × 10(-3) mm(2)/s; minimum blood flow: 2.15 ± 0.14 × 10(-3) mm(2)/s). FA-values of the renal medulla were significantly greater at maximal blood (0.53 ± 0.05) than at minimal blood flow (0.47 ± 0.05) (P < 0.01). In contrast, cortical FA-values were comparable at different timepoints of the cardiac cycle. ADC-values in the renal cortex as well as FA-values in the renal medulla are influenced by renal blood flow. This impact has to be considered when interpreting renal ADC- and FA-values. Copyright © 2012 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Hayashi, Kazuhiro; Hachimori, Wataru; Kaneda, Shogo; Tamura, Shuji; Saito, Taiki
2017-10-01
In case of earthquake damage to buildings, the damage to a superstructure is visible, but the damage to a foundation structure, e.g. the underground pile, is difficult to detect. In this study, the authors aim to develop a monitoring technique for pile damage due to earthquakes. The world's biggest shaking table, E-Defense, was used to reproduce damage to RC pile models embedded in the soil inside a large scale shear box (8m in diameter and 6.5m in height). The diameter of the RC pile model was 154mm. It consisted of mortar (27.2N/mm2 in compressive strength), 6 main reinforcements (6.35mm in diameter) and shear reinforcement hard steel wire (2mm in diameter at intervals of 20mm). The natural period of the superstructure above the pile models is around 0.12sec. The soil consisted of 2 layers. The lower layer is Albany sand of 80% relative density while the upper layer is only 2m from the surface ground and is Kaketsu sand of 60% relative density. Primary four excitations were scaled from JMA Kobe waves in notification at different amplitudes. The maximum acceleration of each wave is 31gal, 67gal, 304gal, and 458gal, respectively. In the test result, reinforcing steels at the pile head of the RC model yielded when the maximum acceleration was 304gal. After that, mortar of the pile head peeled off and a bending shear failure occurred when the maximum acceleration was 458gal. The peak frequency of rotational spectrum on the foundation did not change in elastic range in the piles. However, the peak frequency fell after the plastic hinge occurred.
Liquid-surface entrainment induced by shocked air stream
NASA Astrophysics Data System (ADS)
Rodriguez, V.; Jourdan, G.; Marty, A.; Allou, A.; Parisse, J.-D.
2018-02-01
Recently, we experimentally studied, in a shock tube environment, shock waves propagating over horizontal free water layers having depths of 10, 20, and 30 mm for shock wave Mach numbers M_is equal to 1.1 and 1.4. The qualitative interaction process was observed by means of high-speed visualizations, and the pressures arising in the air and in the water layer were measured and interpreted in terms of the various incident and refracted shock waves in air and water; in particular, it was concluded that the compression wave in the water is driven by the planar shock wave in the air. Additional experiments have been conducted and the novel contributions of the present technical note are quantitative results regarding the liquid-surface entrainment. At low Mach number (M_is=1.1 ), we show that the velocity of the droplets ejected into the air is independent of the water depth, unlike the wavelength of initial ripples and the angle of ejection. When the shock wave strength increases (M_is=1.4 ), the dispersion of a very thin droplet mist and a single large wave take place. We show that the thickening of the water mist and the velocity of the subsequent large wave decreases with the water-layer depth.
Jaeger, Matthias; Khoo, Angela K; Conforti, David A; Cuganesan, Ramesh
2016-11-01
Phase contrast cine MRI with determination of pulsatile aqueductal cerebrospinal fluid (CSF) stroke volume and flow velocity has been suggested to assess intracranial pulsations in idiopathic normal pressure hydrocephalus (iNPH). We aimed to compare this non-invasive measure of pulsations to intracranial pressure (ICP) pulse wave amplitude from continuous ICP monitoring. We hypothesised that a significant correlation between these two markers of intracranial pulsations exists. Fifteen patients with suspected iNPH had continuous computerised ICP monitoring with calculation of mean ICP pulse wave amplitude (MWA) from time-domain analysis. MRI measured CSF aqueductal stroke volume and peak flow velocity. Mean MWA was 5.4mmHg (range 2.3-12.4mmHg). Mean CSF stroke volume and peak flow velocity were 65μl (range 3-195μl) and 9.31cm/s (range 1.68-15.0cm/s), respectively. No significant correlation between the invasive and non-invasive measures of pulsations existed (Spearman r=-0.30 and r=-0.27, respectively; p>0.05). We observed marked intra-individual fluctuation of MWA during continuous ICP monitoring of an average of 6.0mmHg (range 2.8-12.2mmHg). The results suggest a complex interplay between measures of pulsations derived from snapshot MRI measurements and continuous computerised ICP measurements, as no significant relationship existed in our data. Further study is needed to better understand the temporal profile of CSF MRI flow studies, as substantial variation in MWA over the course of several hours of ICP monitoring is common, suggesting that these physiologic fluctuations might obscure MRI snapshot measures of intracranial pulsations. Copyright © 2016 Elsevier Ltd. All rights reserved.
Rautaharju, Pentti M; Menotti, Alessandro; Blackburn, Henry; Parapid, Biljana; Kircanski, Bratislav
2012-01-01
Isolated T-wave findings are generally considered of little importance in clinical electrocardiogram (ECG) interpretation, although a few studies have associated them with excess mortality risk. We used Cox regression models to evaluate coronary heart disease (CHD) mortality risk for isolated inverted T waves in 8713 men in the Seven Countries Study with no manifest cardiac diseases at baseline. The study population was stratified into 3 mutually exclusive groups: (1) isolated inverted T waves in the absence of other codable ECG findings according to the Minnesota Code; (2) other ECG findings with or without negative T waves; and (3) no codable ECG findings, used as the reference group. Mortality follow-up of the entire cohort was performed at 5, 10, 20, 30, and 40 years. The prevalence of isolated negative T waves at baseline was low, 1.6%, in these men from working populations. The hazard ratio (HR) for CHD mortality risk after 5 years in the isolated T-wave inversion group was more than 3 times greater than that in the reference group after adjusting for age, body mass index, cigarette smoking, systolic blood pressure, serum cholesterol and cohort (HR 3.68, 95% confidence interval [1.44-9.37]). Hazard ratio declined gradually with the length of follow-up but was still at 50% excess risk at 40-year follow-up (HR 1.51, 95% confidence interval [1.12-2.05]). T waves in the isolated T-wave inversion group were "flat" or less negative than 1mm (-100 μV) in the majority (86%) of inverted T waves. We conclude that inverted T waves with even a minor degree of negativity as an isolated ECG finding in men with no evidence of heart disease predict an excess short-term and long-term risk of CHD death. Copyright © 2012 Elsevier Inc. All rights reserved.
Girolamo, Donato; Chang, Huan-Yu; Yuan, Fuh-Gwo
2018-07-01
A fully non-contact laser-based nondestructive inspection (NDI) system is developed to detect and visualize damage in structures. The study focuses on the size quantification and characterization of a barely visible impact damage (BVID) in a honeycomb composite panel. The hardware consists of a Q-switched Nd:YAG pulse laser that probes the panel by generating broadband guided waves via thermo-elastic expansion. The laser, in combination with a set of galvano-mirrors is used to raster scan over a two-dimensional surface covering the damaged region of an impacted quasi-isotropic [60/0/-60] s honeycomb composite panel. The out-of-plane velocities are measured at a fixed location normal to the surface by a laser Doppler vibrometer (LDV). An ultrasonic full wavefield assembled from the three-dimensional space-time data matrix in the interrogated area is first acquired and then processed for imaging the impacted damage area. A wavenumber filtering technique in terms of wave vectors is applied to distinguish the forward and backward wavefields in the wavenumber-frequency domain. A zero-lag cross correlation (ZLCC) imaging condition is then employed in the space-frequency domain for damage imaging. The ZLCC imaging condition consists of cross correlating the incident and reflected wavefields in the entire scanned region. The condition not only images the damage boundary between incident and reflected waves outside the damage region but also, for longer time windows, enables to capture the momentary standing waves formed within the damaged region. The ZLCC imaging condition imaged two delaminated region: a main delamination, which was a skewed elliptic with major and minor axis lengths roughly 17 mm and 10 mm respectively, and a secondary delamination region approximately 6 mm by 4 mm, however, which can only be shown at higher frequency range around 80-95 kHz. To conclude, the ZLCC results were in very good agreement with ultrasonic C-scan and X-ray computed tomographic (X-ray CT) scan results. Since the imaging condition is performed in the space-frequency domain, the imaging from ZLCC can also reveal resonance modes which are shown in the main delaminated area by windowing a narrow frequency band sequentially. Published by Elsevier B.V.
Gomez-Marcos, Manuel A; Recio-Rodríguez, Jose I; Patino-Alonso, Maria C; Agudo-Conde, Cristina; Gomez-Sanchez, Leticia; Rodriguez-Sanchez, Emiliano; Gomez-Sanchez, Marta; Garcia-Ortiz, Luis
2011-10-14
Cardiovascular disease morbidity-mortality is greater in people with type 2 diabetes mellitus or metabolic syndrome. The purpose of this study was to evaluate the yearly evolution of organ damage markers in diabetes or metabolic syndrome, and to analyze the associated factors. An observational prospective study was carried out in the primary care setting, involving 112 patients: 68 diabetics and 44 subjects with metabolic syndrome, subjected to 12 months of follow-up. traditional cardiovascular risk factors (blood pressure, blood glucose, lipids, smoking, body mass index (BMI) and) and non-traditional risk factors (waist circumference, hsC Reactive Protein and fibrinogen); subclinical vascular (carotid intima-media thickness, pulse wave velocity and ankle/brachial index), cardiac (Cornell voltage-duration product), renal organ damage (creatinine, glomerular filtration and albumin/creatinine index), and antihypertensive and lipid-lowering drugs. At baseline, the diabetics presented a mean age of 59.9 years, versus 55.2 years in the subjects with metabolic syndrome (p = 0.03). Diastolic blood pressure, total cholesterol and HDL-cholesterol were lower among the patients with diabetes, while blood glucose and HbA1c, as well as antihypertensive and lipid-lowering drug use, were greater. At evaluation after one year, the diabetics showed a decrease in BMI (-0.39), diastolic blood pressure (-3.59), and an increase in fibrinogen (30.23 mg/dL), ankle/brachial index (0.07) and the number of patients with ankle/brachial index pathologic decreased in 6. In turn, the patients with metabolic syndrome showed an increase in HDL-cholesterol (1-91 mg/dL), fibrinogen (25.54 mg/dL), Cornell voltage-duration product (184.22 mm/ms), ankle/brachial index (0.05) and the use of antihypertensive and lipid-lowering drugs, and a reduction in serum glucose (3.74 mg/dL), HOMA, systolic (-6.76 mmHg), diastolic blood pressure (-3.29 mmHg), and pulse wave velocity (-0.72 m/s). The variable that best predicted a decrease in pulse wave velocity in subjects with metabolic syndrome was seen to be an increase in antihypertensive drug use. The annual assessment of cardiovascular risk factors and the decrease in pulse wave velocity was more favorable in the patients with metabolic syndrome, probably influenced by the increased percentage of subjects treated with antihypertensive and lipid lowering drugs in this group.
NASA Astrophysics Data System (ADS)
Moraru, Ciprian G.
The ability to predict the onset of boundary-layer transition is critical for hypersonic flight vehicles. The development of prediction methods depends on a thorough comprehension of the mechanisms that cause transition. In order to improve the understanding of hypersonic boundary-layer transition, tests were conducted on a large 7° half-angle cone at Mach 10 in the Arnold Engineering Development Complex Wind Tunnel 9. Twenty-four runs were performed at varying unit Reynolds numbers and angles of attack for sharp and blunt nosetip configurations. Heat-transfer measurements were used to determine the start of transition on the cone. Increasing the unit Reynolds number caused a forward movement of transition on the sharp cone at zero angle of attack. Increasing nosetip radius delayed transition up to a radius of 12.7 mm. Larger nose radii caused the start of transition to move forward. At angles of attack up to 10°, transition was leeside forward for nose radii up to 12.7 mm and windside forward for nose radii of 25.4 mm and 50.8 mm. Second-mode instability waves were measured on the sharp cone and cones with small nose radii. At zero angle of attack, waves at a particular streamwise location on the sharp cone were in earlier stages of development as the unit Reynolds number was decreased. The same trend was observed as the nosetip radius was increased. No second-mode waves were apparent for the cones with large nosetip radii. As the angle of attack was increased, waves at a particular streamwise location on the sharp cone moved to earlier stages of growth on the windward ray and later stages of growth on the leeward ray. RMS amplitudes of second-mode waves were computed. Comparison between maximum second-mode amplitudes and edge Mach numbers showed good correlation for various nosetip radii and unit Reynolds numbers. Using the e N method, initial amplitudes were estimated and compared to freestream noise in the second-mode frequency band. Correlations indicate that freestream noise likely has a significant influence on initial second-mode amplitudes.
Parsaee, Mozhgan; Ghaderi, Fereshteh; Alizadehasl, Azin; Bakhshandeh, Hooman
2016-08-01
Echocardiography is a key screening tool in the diagnostic algorithm of pulmonary hypertension (PH). In addition, tissue doppler imaging (TDI) is a promising method for the noninvasive estimation of pulmonary artery pressure (PAP). The aim of this study was to validate the accuracy of measuring the time from the beginning of the right ventricular isovolumetric contraction time (RV IVRT) to the peak of the S wave in the TDI of the base of the RV free wall (time to peak or TTP), as an indicator for the non-invasive estimation of pulmonary hypertension. In this diagnostic test study, 60 consecutive patients referred for right heart catheterization (RHC) were enrolled. A pulse-wave TDI was performed before the cardiac catheterization, with a mean interval of 1 hour between the two measurements. The TDI variables, such as the RV IVRT, myocardial performance index (MPI), and the new "time to peak" parameter, were measured at the lateral basal RV free wall. The patients were divided into two sub-groups according to the RHC findings: no-PH (mean PAP < 25 mmHg) and PH (mean PAP ≥ 25 mmHg) groups. Then, we calculated the specificity and sensitivity of the TDI parameters (including the TTP) for the diagnosis of PH. In our study, the TTP showed a significant inverse relationship with the PAP. Based on our results, a TTP of less than 127 ms could be used to predict PH, with a sensitivity and specificity of about 70% (AUC = 0.746 ± 0.064). Based on the results of this study, we suggest the use of a novel "time from the beginning of isovolumetric contraction to the peak of the S wave" (TTP) parameter in the TDI of the base of the RV free wall to predict PH with acceptable accuracy in comparison with RHC.
NASA Astrophysics Data System (ADS)
Chen, S. T.; Chen, W. S.
2016-12-01
Since late Pleistocene, the Coastal Range (Philippine Sea plate) collided and overridden on the Central Range (Eurasian Plate) along the Longitudinal Valley Fault. Therefore, the Coastal Range is exposed widely the late Pleistocene-Holocene marine and fluvial terraces caused by the tectonic uplift. Based on the estimation of paleosea-level elevations (Δh), depositional paleodepth, altitude distribution of Holocene deposits (D), altitude of outcrops (H), and 14C dating of marine deposits (t), the uplift rate (=(Δh+H +d-D)/t) is about 5-10 mm/yr in the southern Coastal Range. In this study, we suggest through field logging that the deposits can be divided into alluvial, foreshore (intertidal), shoreface, and offshore environments. In Dulan area in the southern Coastal Range, the uplift rate was 6-7 mm/yr during 16,380-10,000 cal yr BP and 3-4 mm/yr after 7,000 cal yr BP. Results from the Dulan Coastal alluvial-fan system can be divided into five depositional stages: (1) 16,380-14,300 cal yr BP: The rate of global sea level rise (SLR) has averaged about 6-7 mm/yr, similar to the tectonic uplift rate. In this stage, the bedrock was eroded and formed a wide wave-cut platform. (2) 14,300-10,000 cal yr BP: SLR of about 14 mm/yr that was faster than tectonic uplift rate of 6-7 mm/yr. As a result of transgression, the beach-lagoon deposits about 5 m thick were unconformably overlain on the wave-cut platform. (3) 10,000-8,200 cal yr BP: The ongoing sea level rise (SLR: 11 mm/yr), the lagoon deposits were overlain by an offshore slump deposits representing a gradual deepening of the depositional environment. (4) 8,200-7,930 cal yr BP (SLR: 6-7 mm/yr): The tectonic uplift rate may occur at similar SLR. The alluvial-fan deposits have prograded over the shallow marine deposits. (5) After 7,000 cal yr BP (SLR: 1-0 mm/yr): SLR was much slower than tectonic uplift rate of 3-4 mm/yr. Thus, Holocene marine terraces are extensively developed in the coastal region, showing that the Holocene marine deposits rest above the fluvial deposits. The crustal high uplift rates of relative sea-level changes led to form a well-developed multiple Holocene marine terraces.
Transmission of 100-MHz-range ultrasound through a fused quartz fiber.
Irie, Takasuke; Tagawa, Norio; Tanabe, Masayuki; Moriya, Tadashi; Yoshizawa, Masasumi; Iijima, Takashi; Itoh, Kouichi; Yokoyama, Taku; Kumagai, Hideki; Taniguchi, Nobuyuki
2011-07-01
This paper describes an investigation into direct observation of microscopic images of tissue using a thin acoustic wave guide. First, the characteristics of the ultrasonic wave propagated in a fused quartz fiber were measured using the reflection method in order to study the insertion loss and the frequency shift of the ultrasonic wave transmitted from the transducer. Next, a receiving transducer was placed close to the end of the fiber, and the characteristics of the ultrasonic waves propagated through the acoustic coupling medium were measured using the penetration method in order to study the insertion loss and the frequency-dependent attenuation of the penetrated waves. Finally, a C-mode image was obtained by optimizing the measuring conditions using the results of the above measurements and scanning the ultrasonic beams on a target (coin) in water. A reflected wave with a peak frequency of approximately 220 MHz was obtained from the end of the fiber. The transmitted ultrasonic waves propagated through the acoustic coupling medium were detected with a frequency range of approximately 125-170 MHz, and the maximum detectable distance of the waves was approximately 1.2 mm within the 100-MHz frequency range. Finally, a high-frequency C-mode image of a coin in water was obtained using a tapered fused quartz fiber. The results suggest that it is necessary to improve the signal-to-noise ratio and reduce the insertion loss in the experimental system in order to make it possible to obtain microscopic images of tissue.
SLOW MAGNETOACOUSTIC WAVES OBSERVED ABOVE A QUIET-SUN REGION IN A DARK CAVITY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu Jiajia; Zhou Zhenjun; Wang Yuming
Waves play a crucial role in diagnosing the plasma properties of various structures in the solar corona and coronal heating. Slow magnetoacoustic (MA) waves are one of the important types of magnetohydrodynamic waves. In past decades, numerous slow MA waves were detected above active regions and coronal holes, but were rarely found elsewhere. Here, we investigate a 'tornado'-like structure consisting of quasi-periodic streaks within a dark cavity at about 40-110 Mm above a quiet-Sun region on 2011 September 25. Our analysis reveals that these streaks are actually slow MA wave trains. The properties of these wave trains, including phase speed,more » compression ratio, and kinetic energy density, are similar to those of the reported slow MA waves, except that the period of these waves is about 50 s, much shorter than the typical reported values (3-5 minutes).« less
Measurement and imaging of infragravity waves in sea ice using InSAR
NASA Astrophysics Data System (ADS)
Mahoney, Andrew R.; Dammann, Dyre O.; Johnson, Mark A.; Eicken, Hajo; Meyer, Franz J.
2016-06-01
Using short-temporal baseline interferometric synthetic aperture radar, we capture instantaneous images of a persistent field of infragravity waves propagating through sea ice near Barrow, Alaska, during January 2015. We estimate wave amplitudes to be between 1.2 and 1.8 mm. Curvature of wavefronts is consistent with refraction of waves entering shallow water from a source region north of Barrow. A shallow water wave model indicates that the geometry of the wavefronts is relatively insensitive to the source location, but other evidence suggests the waves may have originated in the North Atlantic, making this perhaps the longest observed propagation path for waves through ice. We also note that steepening of the waves entering shallow water can increase the peak strain by an order of magnitude, suggesting that infragravity waves may play a role in determining the location of the landfast ice edge with respect to water depth.
High-frequency shear-horizontal surface acoustic wave sensor
Branch, Darren W
2013-05-07
A Love wave sensor uses a single-phase unidirectional interdigital transducer (IDT) on a piezoelectric substrate for leaky surface acoustic wave generation. The IDT design minimizes propagation losses, bulk wave interferences, provides a highly linear phase response, and eliminates the need for impedance matching. As an example, a high frequency (.about.300-400 MHz) surface acoustic wave (SAW) transducer enables efficient excitation of shear-horizontal waves on 36.degree. Y-cut lithium tantalate (LTO) giving a highly linear phase response (2.8.degree. P-P). The sensor has the ability to detect at the pg/mm.sup.2 level and can perform multi-analyte detection in real-time. The sensor can be used for rapid autonomous detection of pathogenic microorganisms and bioagents by field deployable platforms.
High-frequency shear-horizontal surface acoustic wave sensor
Branch, Darren W
2014-03-11
A Love wave sensor uses a single-phase unidirectional interdigital transducer (IDT) on a piezoelectric substrate for leaky surface acoustic wave generation. The IDT design minimizes propagation losses, bulk wave interferences, provides a highly linear phase response, and eliminates the need for impedance matching. As an example, a high frequency (.about.300-400 MHz) surface acoustic wave (SAW) transducer enables efficient excitation of shear-horizontal waves on 36.degree. Y-cut lithium tantalate (LTO) giving a highly linear phase response (2.8.degree. P-P). The sensor has the ability to detect at the pg/mm.sup.2 level and can perform multi-analyte detection in real-time. The sensor can be used for rapid autonomous detection of pathogenic microorganisms and bioagents by field deployable platforms.
Energy scavenging system by acoustic wave and integrated wireless communication
NASA Astrophysics Data System (ADS)
Kim, Albert
The purpose of the project was developing an energy-scavenging device for other bio implantable devices. Researchers and scientist have studied energy scavenging method because of the limitation of traditional power source, especially for bio-implantable devices. In this research, piezoelectric power generator that activates by acoustic wave, or music was developed. Follow by power generator, a wireless communication also integrated with the device for monitoring the power generation. The Lead Zirconate Titanate (PZT) bimorph cantilever with a proof mass at the free end tip was studied to convert acoustic wave to power. The music or acoustic wave played through a speaker to vibrate piezoelectric power generator. The LC circuit integrated with the piezoelectric material for purpose of wireless monitoring power generation. However, wireless monitoring can be used as wireless power transmission, which means the signal received via wireless communication also can be used for power for other devices. Size of 74 by 7 by 7cm device could generate and transmit 100mVp from 70 mm distance away with electrical resonant frequency at 420.2 kHz..
NASA Astrophysics Data System (ADS)
Herbold, Eric
2005-07-01
Strongly nonlinear phononic crystals were assembled from chains of stainless steel spheres with diameter 4.78 mm. Propagation of solitary waves and splitting of initial pulse into train of solitary waves excited by the impact of piston was investigated in different viscous media in experiments and in numerical calculations. Oil of various grades was used to introduce controlled dissipation into the system. Preliminary results indicate that splitting of the initial pulse into the train of solitary waves was dramatically influenced by viscosity. This work was supported by NSF (Grant No. DCMS03013220).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sahu, Debaprasad; Bhattacharjee, Sudeep
2012-09-15
Localized wave-induced resonances are created by microwaves launched directly into a multicusp (MC) plasma device in the k Up-Tack B mode, where k is the wave vector and B is the static magnetic field. The resonance zone is identified as upper hybrid resonance (UHR), and lies r = {approx}22 mm away from the MC boundary. Measurement of radial wave electric field intensity confirms the right hand cutoff of the wave (r = 22.5-32.1 mm) located near the UHR zone. A sharp rise in the corresponding electron temperature in the resonance region by {approx}13 eV from its value away from resonancemore » at r = 0, is favorable for the generation of vibrationally excited molecules of hydrogen. A transverse magnetic filter allows cold electrons ({approx}1-2 eV) to pass into the downstream region where they generate negative ions by dissociative attachment. Measurements of electron energy distribution function (EEDF) support the viewpoint. H{sup -} current density of {approx}0.26 mA/cm{sup 2} is obtained at a wave power density of {approx}3 W/cm{sup 2} at 2.0 mTorr pressure, which agrees reasonably well with results obtained from a steady state model using particle balance equations.« less
Scanning dimensional measurement using laser-trapped microsphere with optical standing-wave scale
NASA Astrophysics Data System (ADS)
Michihata, Masaki; Ueda, Shin-ichi; Takahashi, Satoru; Takamasu, Kiyoshi; Takaya, Yasuhiro
2017-06-01
We propose a laser trapping-based scanning dimensional measurement method for free-form surfaces. We previously developed a laser trapping-based microprobe for three-dimensional coordinate metrology. This probe performs two types of measurements: a tactile coordinate and a scanning measurement in the same coordinate system. The proposed scanning measurement exploits optical interference. A standing-wave field is generated between the laser-trapped microsphere and the measured surface because of the interference from the retroreflected light. The standing-wave field produces an effective length scale, and the trapped microsphere acts as a sensor to read this scale. A horizontal scan of the trapped microsphere produces a phase shift of the standing wave according to the surface topography. This shift can be measured from the change in the microsphere position. The dynamics of the trapped microsphere within the standing-wave field was estimated using a harmonic model, from which the measured surface can be reconstructed. A spherical lens was measured experimentally, yielding a radius of curvature of 2.59 mm, in agreement with the nominal specification (2.60 mm). The difference between the measured points and a spherical fitted curve was 96 nm, which demonstrates the scanning function of the laser trapping-based microprobe for free-form surfaces.
A novel optical millimeter-wave signal generation approach to overcome chromatic dispersion
NASA Astrophysics Data System (ADS)
Liang, Dong; Jiang, Wei; Tan, Qinggui; Zhu, Zhongbo; Liu, Feng
2014-06-01
In this paper, a novel frequency octupling approach for optical millimeter-wave signal generation to overcome chromatic dispersion is proposed and demonstrated. The frequency octupling mm-wave with the baseband signal carried only by -4th order sideband is generated by properly adjusting a series of parameters, which are the modulation constant, the gain of baseband signal, the direct current bias and the different phase of the modulation arms. As the optical millimeter-wave signal is transmitted along the fiber, there is no time shift caused by chromatic dispersion. Theoretical analyses and simulated results show that when the optical mm-wave carrying 2.5 Gbps baseband signal transmits a distance of over 110 km, the eye diagram still keeps open and clear. The power penalty is about 0.4 dB after the optical signal transmits over 40 km. In additions, given the +4th order sideband carries no data, a full-duplex RoF link based on wavelength reuse is built for the uplink. The bidirectional 2.5 Gbps baseband signal could successfully transmit over 40 km with about 0.8 dB power penalty in the simulation. Both theoretical analyses and simulation results show that the full-duplex RoF link has good performance.
Estimation of in-situ stresses in concrete members using polarized ultrasonic shear waves
NASA Astrophysics Data System (ADS)
Chen, Andrew; Schumacher, Thomas
2014-02-01
Ultrasonic testing is commonly used to detect flaws, estimate geometries, and characterize properties of materials and structures. Acoustoelasticity refers to the dependency of stress wave velocity with applied stresses and is a phenomenon that has been known by geophysicists since the 1960s. A way to capitalize on this effect for concrete applications is by using ultrasonic shear waves which are particularly sensitive to applied stresses when polarized in the direction of the applied stress. The authors conducted an experiment on a 150 mm (6 in.) diameter concrete cylinder specimen with a length of 305 mm (12 in.) that was loaded in discrete load steps to failure. At each load step two ultrasonic shear waves were transmitted through the specimen, one with the polarization perpendicular and the other transverse to the applied stress. The velocity difference between the two sets of polarized shear waves was found to correlate with the applied stress in the specimen. Two potential applications for this methodology include estimation of stresses in pre-stressed concrete bridge girders and investigation of load redistribution in structural support elements after extreme events. This paper introduces the background of the methodology, presents an analysis of the collected data, and discusses the relationship between the recorded signals and the applied stress.
Ioppolo, Francesco; Tattoli, Maria; Di Sante, Luca; Attanasi, Carmine; Venditto, Teresa; Servidio, Marila; Cacchio, Angelo; Santilli, Valter
2012-11-01
Extracorporeal shock-wave therapy (ESWT) represents a valid intervention in the treatment of people with supraspinatus calcifying tendinitis (SCT), but there is limited evidence for the useful range of ESWT doses. The aim of this study was to compare 2 different ranges of energy flux density in treatment of SCT with ESWT. This study was designed as a single-blind randomized clinical trial. This study was performed in a university hospital. Forty-six patients with SCT were randomly assigned to 2 groups that received different therapeutic energy doses of ESWT: (1) group A received ESWT at an energy level of 0.20 mJ/mm², and (2) group B received ESWT at an energy level of 0.10 mJ/mm². The treatment protocol consisted of 4 sessions performed once a week. The change in mean Constant Murley Scale (CMS) scores at 3 and 6 months was the primary endpoint. The change in the mean visual analog scale (VAS) scores from baseline to 3 and 6 months after the intervention and radiographic change in size of calcium deposits were evaluated as secondary endpoints. At 12 months, pain relief was assessed using a numeric rating scale. Significant clinical improvement based on mean CMS scores was observed after 6 months in group A (X=79.43, SD=10.33) compared with group B (X=57.91, SD=6.53). Likewise, after 6 months, a significant decrease in VAS scores was found in group A (X=2.09, SD=1.54) compared with group B (X=5.36, SD=0.78). Calcific deposits disappeared in the same percentage of patients in both groups. The small sample size and lack of a control group were limitations of the study. In ESWT for SCT, an energy level of 0.20 mJ/mm² appears to be more effective than an energy level of 0.10 mJ/mm² in pain relief and functional improvement.
Iro, H; Zenk, J; Hosemann, W G; Benzel, W
1993-08-01
Extracorporeal lithotripsy is now used routinely for the treatment of salivary duct stones. The question arose whether electrohydraulic intracorporeal lithotripsy, which is applied in urology and gastroenterology, might also be useful in the treatment of this disease. Before its possible clinical application the influence of electrohydraulic intracorporeal shock waves on salivary stones in vitro and any influence on the tissue in the head and neck region (in vivo) had to be investigated. In vitro experiments. Fifty-eight salivary stones and 11 extirpated human submandibular glands were treated by three different electrohydraulic devices. Animal experiments. Electrohydraulic shock waves were applied to the dilated Stensen's duct and other tissues (muscle, parotid gland, facial nerve) of six rabbits. Of 58 salivary stones, 53 (91%) were fragmented, 39 (67%) with a remaining size of less than 1.5 mm and 14 (24%) more than 1.5 mm. In 5 cases (9%) no effects were seen at all. Fragmentation occurred independent of the mineralogical components of the stone and independent of the different lithotriptors used. The smaller the probe diameter and the larger the stone, the more shock waves were needed to achieve fragmentation. With the smaller probes the stones could not be fragmented completely. In human submandibular glands, extensive tissue lesions could be evidenced macroscopically and histologically after application of electrohydraulic shock waves in vitro. Application of electrohydraulic shock waves to the dilated parotid gland duct of rabbits led to perforations of the duct after 1-5 single pulses. Lesions of nerves and blood vessels could also be observed within the duct environment. This occurred with all of the different electrohydraulic devices, probe diameters and intensities used. In our opinion the damage produced is probably the result of both the direct effect of the plasma as well as the resultant stress wave. In view of the severe damage caused to different tissues, use of the described method for the treatment of stones in the narrow human salivary ducts should be greatly restricted.
Argyriou, Christos; Georgakarakos, Efstratios; Georgiadis, George S; Schoretsanitis, Nikolaos; Lazarides, Miltos K
2017-08-01
Patients undergoing revascularization for infrarenal aortic occlusion (IAO) have been reported to present improved survival rates compared to those treated conservatively. Aim of this study was to investigate the hemodynamic changes induced after revascularization for IAO, as expressed with pulse wave velocity (PWV), augmentation index (Aix), augmentation pressure (AP), and pulse wave reflection coefficient (RC). Twelve patients underwent revascularization (9 aortobifemoral/aortobiiliac bypasses, 2 primary iliac stenting, and 1 hybrid procedure of unilateral aortoiliac stenting and crossover bypass). Calculation of hemodynamic parameters was performed in all patients preoperatively, at 1 month, and 1 year postoperatively. Pulse wave analysis was performed noninvasively with a novel validated brachial cuff-based automatic oscillometric device (Mobil-O-Graph; IEM, Stolberg, Germany). The estimated hemodynamic parameters were AIx, AP, RC, and PWV. Data were analyzed with the Friedman analysis of variance test. Aix decreased significantly at 1 month and further at 1 year postoperatively compared to preoperative values (24 ± 11 and 17 ± 13 vs. 34 ± 13.5, respectively, P = 0.0006). AP decreased at 1 month and 1 year postoperatively compared to preoperative values (6.5 ± 4 mm Hg and 8 ± 6.5 mm Hg vs. 13 ± 12 mm Hg, respectively, P = 0.045). RC decreased also at 1-month and 1-year postoperatively compared to preoperative values (62 ± 5.5, 64 ± 4.3 vs. 73 ± 5.1, respectively, P = 0.002). However, changes in PWV were less prominent in this short-term postoperative period. Improved hemodynamic profile may theoretically contribute to the enhanced survival rates of these patients. Copyright © 2017 Elsevier Inc. All rights reserved.
Yotti, Raquel; Bermejo, Javier; Gutiérrez-Ibañes, Enrique; Pérez del Villar, Candelas; Mombiela, Teresa; Elízaga, Jaime; Benito, Yolanda; González-Mansilla, Ana; Barrio, Alicia; Rodríguez-Pérez, Daniel; Martínez-Legazpi, Pablo; Fernández-Avilés, Francisco
2015-02-10
Systemic arterial load impacts the symptomatic status and outcome of patients with calcific degenerative aortic stenosis (AS). However, assessing vascular properties is challenging because the arterial tree's behavior could be influenced by the valvular obstruction. This study sought to characterize the interaction between valvular and vascular functions in patients with AS by using transcatheter aortic valve replacement (TAVR) as a clinical model of isolated intervention. Aortic pressure and flow were measured simultaneously using high-fidelity sensors in 23 patients (mean 79 ± 7 years of age) before and after TAVR. Blood pressure and clinical response were registered at 6-month follow-up. Systolic and pulse arterial pressures, as well as indices of vascular function (vascular resistance, aortic input impedance, compliance, and arterial elastance), were significantly modified by TAVR, exhibiting stiffer vascular behavior post-intervention (all, p < 0.05). Peak left ventricular pressure decreased after TAVR (186 ± 36 mm Hg vs. 162 ± 23 mm Hg, respectively; p = 0.003) but remained at >140 mm Hg in 70% of patients. Wave intensity analysis showed abnormally low forward and backward compression waves at baseline, increasing significantly after TAVR. Stroke volume decreased (-21 ± 19%; p < 0.001) and correlated with continuous and pulsatile indices of arterial load. In the 48 h following TAVR, a hypertensive response was observed in 12 patients (52%), and after 6-month follow-up, 5 patients required further intensification of discharge antihypertensive therapy. Vascular function in calcific degenerative AS is conditioned by the upstream valvular obstruction that dampens forward and backward compression waves in the arterial tree. An increase in vascular load after TAVR limits the procedure's acute afterload relief. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
An ultrasound look at Korotkoff sounds: the role of pulse wave velocity and flow turbulence.
Benmira, Amir; Perez-Martin, Antonia; Schuster, Iris; Veye, Florent; Triboulet, Jean; Berron, Nicolas; Aichoun, Isabelle; Coudray, Sarah; Laurent, Jérémy; Bereksi-Reguig, Fethi; Dauzat, Michel
2017-04-01
The aim of this study was to analyze the temporal relationships between pressure, flow, and Korotkoff sounds, providing clues for their comprehensive interpretation. When measuring blood pressure in a group of 23 volunteers, we used duplex Doppler ultrasonography to assess, under the arm-cuff, the brachial artery flow, diameter changes, and local pulse wave velocity (PWV), while recording Korotkoff sounds 10 cm downstream together with cuff pressure and ECG. The systolic (SBP) and diastolic (DBP) blood pressures were 118.8±17.7 and 65.4±10.4 mmHg, respectively (n=23). The brachial artery lumen started opening when cuff pressure decreased below the SBP and opened for an increasing length of time until cuff pressure reached the DBP, and then remained open but pulsatile. A high-energy low-frequency Doppler signal, starting a few milliseconds before flow, appeared and disappeared together with Korotkoff sounds at the SBP and DBP, respectively. Its median duration was 42.7 versus 41.1 ms for Korotkoff sounds (P=0.54; n=17). There was a 2.20±1.54 ms/mmHg decrement in the time delay between the ECG R-wave and the Korotkoff sounds during cuff deflation (n=18). The PWV was 10±4.48 m/s at null cuff pressure and showed a 0.62% decrement per mmHg when cuff pressure increased (n=13). Korotkoff sounds are associated with a high-energy low-frequency Doppler signal of identical duration, typically resulting from wall vibrations, followed by flow turbulence. Local arterial PWV decreases when cuff pressure increases. Exploiting these changes may help improve SBP assessment, which remains a challenge for oscillometric techniques.
Vilches, R M; Aliaga, A; Reyes, D; Sepulveda, F; Mercado, A; Moya, F; Ledezma, R; Hidalgo, J P; Olmedo, T; Marchant, F
2015-05-01
Extracorporeal Shock Wave Lithotripsy (ESWL) is currently the recommended treatment for intra-renal calculi smaller than 2 cm. However the low Stone Free Rate (SFR) in lower pole calculi gives rise to new techniques, such us retrograde intrarenal surgery (RIRS), for improve the surgery outcomes. To compare the efficacy of a treatment with ESWL with RIRS, in terms of SFR after surgery, in patients with kidney stones up to 15 mm in the lower pole. A prospective study was carried out in order to assess the results of ESWL and RIRS in patients with lower pole stones less than 15 mm. Among a total of 55 patients, 31 were underwent to ESWL (Group 1) and the remaining 24 to RIRS (Group 2). Clinical data recorded, including general characteristics of each patient, were: calculi size, side, operative time, complications according to Clavien scale, SFR and the presence of residual fragments at 2 months post-treatment assessed by a CT scan. STATA 11 was used to perform the statistical analysis. There were no differences for general descriptors among groups with the exception of a significantly longer operative time for RIRS. The rates of SFR and residual fragments lesser than 3 mm. were lower in the RIRS group than in ESWL ones. RIRS also showed a lower rate of clinically significant fragments (0% vs 42.3%. P < .05). In the subgroup of patients with stones between 10/15 mm RIRS showed higher SFR (75% vs. 41.2%) and a lower rate of stones>3 mm (0% vs. 58.8%), being statistically significant (P < .05). Clavien III or higher complications were not reported in any of the groups. In the treatment of lower pole stone RIRS has the same results than ESWL in terms of SFR. Regarding absence of a clinically significant residual fragment, RIRS was superior to ESWL. A bigger sample size is required in order to confirm this results. Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.
Agarwal, Rolly S; Agarwal, Jatin; Jain, Pradeep; Chandra, Anil
2015-05-01
The ability of an endodontic instrument to remain centered in the root canal system is one of the most important characteristic influencing the clinical performance of a particular file system. Thus, it is important to assess the canal centering ability of newly introduced single file systems before they can be considered a viable replacement of full-sequence rotary file systems. The aim of the study was to compare the canal transportation, centering ability, and time taken for preparation of curved root canals after instrumentation with single file systems One Shape and Wave One, using cone-beam computed tomography (CBCT). Sixty mesiobuccal canals of mandibular molars with an angle of curvature ranging from 20(o) to 35(o) were divided into three groups of 20 samples each: ProTaper PT (group I) - full-sequence rotary control group, OneShape OS (group II)- single file continuous rotation, WaveOne WO - single file reciprocal motion (group III). Pre instrumentation and post instrumentation three-dimensional CBCT images were obtained from root cross-sections at 3mm, 6mm and 9mm from the apex. Scanned images were then accessed to determine canal transportation and centering ability. The data collected were evaluated using one-way analysis of variance (ANOVA) with Tukey's honestly significant difference test. It was observed that there were no differences in the magnitude of transportation between the rotary instruments (p >0.05) at both 3mm as well as 6mm from the apex. At 9 mm from the apex, Group I PT showed significantly higher mean canal transportation and lower centering ability (0.19±0.08 and 0.39±0.16), as compared to Group II OS (0.12±0.07 and 0.54±0.24) and Group III WO (0.13±0.06 and 0.55±0.18) while the differences between OS and WO were not statistically significant. It was concluded that there was minor difference between the tested groups. Single file systems demonstrated average canal transportation and centering ability comparable to full sequence Protaper system in curved root canals.
2010-09-01
REPORT DATE (DD-MM- YYYY) 02-03-2011 2. REPORT TYPE Journal Article 3 . DATES COVERED (From - To) 4. TITLE AND SUBTITLE Semiempirical Dissipation...Spectral wave modeling has been performed for the "£_ <• , r. , r , r M> l . en • .u u i .• rll ;imi nl .K. •ihr (l’ last...wind output). The nonlinear scattering term Sn\\ repre- sents all processes that lead to an exchange of wave en - ergy between the different spectral
2007-03-01
westerly surface winds, the existence of a dry-adiabatic lapse rate, and often the appearance of wave cloud features (Oard, 1993). For a long time...indicate that a large-scale mountain wave feature was present across almost the entire western United States. The GFS indicates this was a standing 31... wave and not a propagating feature since it persisted with very little movement from about 0600 UTC 6 Mar until about 0000 UTC 7 Mar. A cross
Wave Data Acquisition and Hindcast for Saginaw Bay, Michigan.
1983-06-01
Bretschneider (1952) and Mitsuyasu and Kimura (1965) for f the peak fre- %m quency (where fm = f g/U) while the total energy decay rate follows that mm...Spectra of Wind-Generated Gravity Waves," Journal of Physical Oceanography, Vol 5, pp 410-420. Mitsuyasu, Hisashi . 1968. "On the Growth of the...8217 . , / . - . ’ -’ -. .. ’ . .. _..- -’ - Mitsuyasu, Hisashi , and Kirmura, Hisao. 1965. "Wind Wave in Decay Area," Coastal Engineering in Japan, Vol 8, pp 221-35. Ou, Shan-Hwei. 1980 (Sep
Advanced mobile satellite communications using COMETS satellite in MM-wave and Ka-band
NASA Technical Reports Server (NTRS)
Ohmori, Shingo; Isobe, Shunkichi; Takeuchi, Makoto; Naito, Hideyuki
1993-01-01
Early in the 21st century, the demand for personal communications using mobile, hand-held, and VSAT terminals will rapidly increase. In a future system, many different types of services should be provided with one-hop connection. The Communications Research Laboratory (CRL) has studied a future advanced mobile satellite communications system using millimeter wave and Ka band. In 1990, CRL started the Communications and Broadcasting Engineering Test Satellite (COMETS) project. The satellite has been developed in conjunction with NASDA and will be launched in 1997. This paper describes the COMETS payload configuration and the experimental system for the advanced mobile communications mission.
Bischofberger, Andrea S; Ringer, Simone K; Geyer, Hans; Imboden, Isabel; Ueltschi, Gottlieb; Lischer, Christoph J
2006-04-01
To determine via histologic examination and scintigraphy the effect of focused extracorporeal shock wave therapy (ESWT) on normal bone and the bone-ligament interface in horses. 6 horses without lameness. Origins of the suspensory ligament at the metacarpus (35-mm probe depth) and fourth metatarsal bone (5-mm probe depth) were treated twice (days 0 and 16) with 2,000 shocks (energy flux density, 0.15 mJ/mm2). One forelimb and 1 hind limb were randomly treated, and the contralateral limbs served as nontreated controls. Bone scans were performed on days -1 (before ESWT), 3, 16, and 19. Histomorphologic studies of control and treated tissues were performed on day 30. ESWT significantly increased the number of osteoblasts but caused no damage to associated soft tissue structures and did not induce cortical microfractures. A significant correlation between osteoblast numbers and radiopharmaceutical uptake was noticed on lateral views of the hind limb on days 3 and 16 and on caudal views of the forelimb on day 3. Results suggested that ESWT has the potential to increase osteoblast numbers in horses. The correlation between increased osteoblast numbers and radio-pharmaceutical uptake 3 days and 16 days after the first ESWT suggested that stimulation of osteogenesis occurred soon after ESWT. No damage to bone or the bone-ligament interface should occur at the settings used in this study, and ESWT can therefore be administered safely in horses.
Kubozono, Takuro; Miyata, Masaaki; Kawasoe, Shin; Ojima, Satoko; Yoshifuku, Shiro; Miyahara, Hironori; Maenohara, Shigeho; Ohishi, Mitsuru
2017-02-24
Although there have been several reports on the risk factors associated with intima-media thickness (IMT), many questions remain. The purpose of this study was to investigate the association between IMT and cardiovascular risk factors in a Japanese general population.Methods and Results:The study group consisted of 1,583 male subjects undergoing routine health checkups. IMT of the common carotid artery was measured by high-resolution ultrasonography. Brachial-ankle pulse wave velocity (baPWV) was measured using an automated device. Univariate analysis demonstrated that carotid IMT significantly associated with age, body mass index (BMI), systolic blood pressure (SBP), diastolic blood pressure (DBP), baPWV, fasting glucose, low-density lipoprotein cholesterol (LDL-C), triglycerides (TG), and high-density lipoprotein cholesterol (HDL-C). Multiple logistic regression analysis for carotid atherosclerosis (carotid IMT ≥1.0 mm) was performed using obesity (BMI ≥25.0 kg/m 2 ), high BP (SBP ≥130 mmHg or DBP ≥85 mmHg), dyslipidemia (LDL-C ≥140 mg/dL, TG ≥150 mg/dL, or HDL-C <40 mg/dL), impaired fasting glucose (IFG) (fasting glucose ≥110 g/dL), and high baPWV (≥1,400 cm/s). Carotid atherosclerosis was significantly associated with only high baPWV (OR: 2.22, 95% CI: 1.24-4.17, P<0.01). High baPWV was a stronger predictor of early carotid atherosclerosis than high BP, dyslipidemia, or IFG in a Japanese general male population.
Performance Investigation of Millimeter Wave Generation Reliant on Stimulated Brillouin Scattering
NASA Astrophysics Data System (ADS)
Tickoo, Sheetal; Gupta, Amit
2018-04-01
In this work, photonic method of generating the millimeter waves has been done based on Brillouin scattering effect in optical fiber. Here different approaches are proposed to get maximum frequency shift in mm-wave region using only pumps, radio signals with Mach-Zehnder modulator. Moreover for generated signal validation, signals modulated and send to both wired and wireless medium in optical domain. It is observed that maximum shift of 300 GHz is realized using 60 GHz input sine wave. Basically a frequency doubler is proposed which double shift of input frequency and provide better SNR. For the future generation network system, the generation of millimeter waves makes them well reliable for the transmission of the data.
Electrochemical Oxidation of Alkylnitro Compounds PP-1345
2004-08-17
to the solution, to deprotonate the methyl group. Figure 22 shows the voltammetric response recorded in a CH3OH /0.2 M Bu4NBF4 solution containing...Voltammogram of Glassy Carbon (GC) Electrode 50 mM TNT/ CH3OH /0.2 M Bu4NBF4/55 mM NaOH 15 The standard redox potential for this reaction was... reaction ). Addition of 100 mM TNT to the basic solution ( CH3OH /0.2 M Bu4NBF4/ 55 mM NaOH) resulted in the appearance of a new oxidation wave with a
Opposing effects of particle pollution, ozone, and ambient temperature on arterial blood pressure.
Hoffmann, Barbara; Luttmann-Gibson, Heike; Cohen, Allison; Zanobetti, Antonella; de Souza, Celine; Foley, Christopher; Suh, Helen H; Coull, Brent A; Schwartz, Joel; Mittleman, Murray; Stone, Peter; Horton, Edward; Gold, Diane R
2012-02-01
Diabetes increases the risk of hypertension and orthostatic hypotension and raises the risk of cardiovascular death during heat waves and high pollution episodes. We examined whether short-term exposures to air pollution (fine particles, ozone) and heat resulted in perturbation of arterial blood pressure (BP) in persons with type 2 diabetes mellitus (T2DM). We conducted a panel study in 70 subjects with T2DM, measuring BP by automated oscillometric sphygmomanometer and pulse wave analysis every 2 weeks on up to five occasions (355 repeated measures). Hourly central site measurements of fine particles, ozone, and meteorology were conducted. We applied linear mixed models with random participant intercepts to investigate the association of fine particles, ozone, and ambient temperature with systolic, diastolic, and mean arterial BP in a multipollutant model, controlling for season, meteorological variables, and subject characteristics. An interquartile increase in ambient fine particle mass [particulate matter (PM) with an aerodynamic diameter of ≤ 2.5 μm (PM2.5)] and in the traffic component black carbon in the previous 5 days (3.54 and 0.25 μg/m3, respectively) predicted increases of 1.4 mmHg [95% confidence interval (CI): 0.0, 2.9 mmHg] and 2.2 mmHg (95% CI: 0.4, 4.0 mmHg) in systolic BP (SBP) at the population geometric mean, respectively. In contrast, an interquartile increase in the 5-day mean of ozone (13.3 ppb) was associated with a 5.2 mmHg (95% CI: -8.6, -1.8 mmHg) decrease in SBP. Higher temperatures were associated with a marginal decrease in BP. In subjects with T2DM, PM was associated with increased BP, and ozone was associated with decreased BP. These effects may be clinically important in patients with already compromised autoregulatory function.
Almeida, Joana; Monteiro, José; Silva, José A; Bertoquini, Susana; Polónia, Jorge
2016-11-01
There is disagreement whether white coat hypertensives (WCH) have different hemodynamic and structural characteristics compared to normotensives (NT) and hypertensives (HT). We compared cardiovascular prognostic markers (pulse wave velocity [PWV] and aortic stiffness index [ASI]) and data on central hemodynamics and central pressures (augmentation index [AIx], augmentation pressure [AugP] and pulse pressure amplification [PPA]) from aortic pulse wave analysis between NT (n=175), WCH (n=315) and treated HT (n=691), all with 24-h blood pressure (BP) <130/80 and nocturnal BP <120/70 mmHg after matching for age, gender, body mass index (BMI) and and nocturnal BP. The groups were also compared separately in terms of 24-h systolic BP <120 mmHg and 120-129 mmHg. The percentage of non-dippers was 40.1% in NT, 34.5% in WCH and 38.3 in HT. For similar 24-h and nocturnal systolic BP (NT 109/64±7/5, WCH 110/66±7/6, HT 109/64±7/5 mmHg), aortic stiffness was greater in HT (n=691, PWV 10.8±2.6 m/s and ASI 0.33±0.16, p<0.01) than in WCH (n=316, PWV 9.7±2.4 m/s and ASI 0.28±0.17) and NT (n=175, PWV 9.5±2.0 m/s and ASI 0.29±0.15); AugP and AIx were higher (p<0.01) in HT (13.9±8.2 and 29.6±12.6 mmHg) than in WCH (11.5±8.5 mmHg and 24.9±15.2) and NT (11.0±6.4 mmHg and 26.6±11.5). PPA was lower (p<0.01) in HT (11.3±5.5 mmHg) than in WCH (13.2±7.1 mmHg) and in NT (12.4±4.9 mmHg). The findings were similar when the 24-h systolic BP <120 mmHg and 120-129 mmHg subgroups were analyzed separately. Our data suggest that for similar age, gender distribution, BMI, and 24-h and nocturnal BP, aortic stiffness, central aortic pressures and wave reflection in WCH are closer to those of NT than to those with treated HT. This supports the idea that white coat hypertension may be a more benign condition than treated hypertension for similar 24-h and particularly nocturnal BP levels. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.
Cheung, Shilin; Fick, Laura J; Belsham, Denise D; Thompson, Michael
2010-02-01
Isolation of neurons from animal tissue is an important aspect of understanding basic biochemical processes such as the action of hormones and neurotransmitters. In the present work, the focus is on an effort to evaluate the utility of acoustic wave physics for the study of such cells. Immortalised hypothalamic neuronal cells from mouse embryos were cultured on the surface of the gold electrode of a 9.0 MHz thickness-shear mode acoustic wave sensor. These cells, which are clonal, are imposed on the surface of the device at a confluence in the range of 80-100%. The coated sensor is incorporated into a flow-injection configuration such that electrolytes can be introduced in order to examine their effects through measurement by network analysis. Both series resonance frequency, fs, and motional resistance, R(m), were measured in a number of experiments involving the injection of KCl and NaCl into the sensor-neuron system. The various responses to these electrolytes were interpreted in terms of changes in cellular structure associated with the depolarization process. The sensor-neuron system was found to elicit different responses to the addition of KCl and NaCl. Preliminary findings indicate that the TSM sensor does not purely measure changes in the membrane potential upon KCl addition. Typical changes in fs for 15 mM, 30 mM and 60 mM KCl additions were 54 +/- 15, 80 +/- 26 and 142 +/- 58 Hz (mean +/- standard deviation) respectively. Typical changes in R(m) for these KCl additions were 7 +/- 3, 13 +/- 4 and 23 +/- 6 Omega, respectively. These results were concluded after 17 runs at each concentration. Despite the large relative standard deviations, the dependence of f(s) and R(m) with respect to concentration was apparent. Controls performed by coating the TSM sensor with laminin or a cell attachment matrix showed no significant changes in either f(s) or R(m) for the same solutions tested on the sensor-neuron system.
Backscattering enhancement with a finite beam width for millimeter-wavelength weather radars
NASA Astrophysics Data System (ADS)
Kobayashi, Satoru; Tanelli, Simone; Iguchi, Toshio; Im, Eastwood
2004-12-01
Backscattering enhancement from random hydrometeors should increase as wavelengths of radars reach millimeter regions. For 95 GHz radars, the reflectivity of backscattering is expected to increase by 2 dB, due to multiple scattering including backscattering enhancement, for water droplets of diameter of 1 mm with a density of 5 x 103 m-3. Previous theoretical studies of backscattering enhancement considered infinitely extending plane waves. In this paper, we expand the theory to spherical waves with a Gaussian antenna pattern, including depolarizing effects. While the differences from the plane wave results are not great when the optical thickness is small, as the latter increases the differences become significant, and essentially depend on the ratio of radar footprint radius to the mean free path of hydrometeors. In this regime, for a radar footprint that is smaller than the mean free path, the backscattering-enhancement reflectivity corresponding to spherical waves is significantly less pronounced than in the case of the plane wave theory. Hence this reduction factor must be taken into account when analyzing radar reflectivity factors for use in remote sensing applications.
Investigation of Kelvin wave periods during Hai-Tang typhoon using Empirical Mode Decomposition
NASA Astrophysics Data System (ADS)
Kishore, P.; Jayalakshmi, J.; Lin, Pay-Liam; Velicogna, Isabella; Sutterley, Tyler C.; Ciracì, Enrico; Mohajerani, Yara; Kumar, S. Balaji
2017-11-01
Equatorial Kelvin waves (KWs) are fundamental components of the tropical climate system. In this study, we investigate Kelvin waves (KWs) during the Hai-Tang typhoon of 2005 using Empirical Mode Decomposition (EMD) of regional precipitation, zonal and meridional winds. For the analysis, we use daily precipitation datasets from the Global Precipitation Climatology Project (GPCP) and wind datasets from the European Centre for Medium-Range Weather Forecasts (ECMWF) Interim Re-analysis (ERA-Interim). As an additional measurement, we use in-situ precipitation datasets from rain-gauges over the Taiwan region. The maximum accumulated precipitation was approximately 2400 mm during the period July 17-21, 2005 over the southwestern region of Taiwan. The spectral analysis using the wind speed at 950 hPa found in the 2nd, 3rd, and 4th intrinsic mode functions (IMFs) reveals prevailing Kelvin wave periods of ∼3 days, ∼4-6 days, and ∼6-10 days, respectively. From our analysis of precipitation datasets, we found the Kelvin waves oscillated with periods between ∼8 and 20 days.
NASA Astrophysics Data System (ADS)
Rahman, B. M. Farid
Modern communications systems are following a common trend to increase the operational frequency, level of integration and number of frequency bands. Although 90-95% components in a cell phone are passives which take 80% of the total board area. High performance RF passive components play limited role and are desired towards this technological advancement. Slow wave structure is one of the most promising candidates to design compact RF and mm-Wave passive components. Slow wave structures are the specially designed transmission line realized by placing the alternate narrow and wide signal conductors in order to reduce the physical size of the components. This dissertation reports multiband slow wave structures integrated with ferromagnetic and ferroelectric thin films and their RF applications. A comparative study on different types of coplanar wave-guide (CPW) slow wave structures (SWS) has been demonstrated for the first time. Slow wave structures with various shapes have been investigated and optimized with various signal conductor shapes, ground conductor shapes and pitch of the sections. Novel techniques i.e. the use of the defected ground structure and the different signal conductor length has been implemented to achieve higher slow wave effect with minimum loss. The measured results have shown the reduction of size over 43.47% and 37.54% in the expense of only 0.27dB and 0.102dB insertion loss respectively which can reduce the area of a designed branch line coupler by 68% and 61% accordingly. Permalloy (Py) is patterned on top of the developed SWS for the first time to further increase the slow wave effect and provide tunable inductance value. High frequency applications of Py are limited by its ferro-magnetic resonance frequency since the inductance value decreases beyond that. Sub-micrometer patterning of Py has increased FMR frequency until 6.3GHz and 3.2GHz by introducing the shape anisotropy. For the SWS with patterned Py, the size of the quarter wavelength has been reduced from 14.86mm to 4.7mm at 2GHz. DC current which is the most convenient and available tuning parameter in a practical circuit board has been used, the developed SWS can function as quarter wave transmission line from 2GHz to 1.80GHz (i.e. 10%). Lead Zirconium Titanate (PZT) is grown and patterned on top of the section with standard sol-gel method to increase capacitance value. The inter digit capacitor type structure along with PZT thin film has been adopted and results showed capacitance value increment by 36%. An electric field between signal and ground has been applied to change the polarization of the thin film which resulted in a tuning of center frequency by 15% (1.75GHz to 2GHz). In addition, a novel approach has been implemented by integrating both the ferromagnetic and the ferroelectric thin films simultaneously to achieve higher slow wave effect, wider tuning range and smaller variation in Characteristics Impedance. The size of the final structure for a quarter wavelengths has been reduced from 14.86mm to 3.98mm while the center frequency has been tuned from 2GHz to 1.5GHz (i.e. 25%). Tunable RF applications of the ferro-magnetic thin films are also demonstrated as a DC current band pass filter, tunable noise suppressor and meander line inductor. A well designed frequency tunable band pass filter (BPF) is implemented at 4GHz with patterned Permalloy. The pass band frequency of a band pass filter has been tuned from 4GHz to 4.02GHz by applying a DC current. The suppression frequency of the developed noise suppressor is tuned from 4.8GHz to 6GHz and 4GHz to 6GHz by changing the aspect ratio of the Py bars and the gap in between them. Moreover, a novel way of tuning the stop band frequency of the noise suppressor by using an external direct current changed the suppression frequency from 6GHz to 4.3GHz. A pass band loss of 1.5%, less than 2° transmitted signal phase distortion, and 3 dB extra return loss of the designed noise suppressor showed the promise the noise suppressors. The increase in the number of turns of a meander line inductor has increased the inductance density from 2565nH/m to 3396nH/m while application of the patterned Py has increased the inductance density from 2565nH/m to 3060nH/m. The tuning of the meander line inductor has been performed by applying DC current until the FMR frequency 4.51GHz.
Zhang, Jidong; Wang, Yan; Hu, Haijuan; Yang, Xiaohong; Tian, Zejun; Liu, Demin; Gu, Guoqiang; Zheng, Hongmei; Xie, Ruiqin; Cui, Wei
2016-01-01
Background Nifedipine gastrointestinal therapeutic system (GITS) is used to treat angina and hypertension. The authors aimed to study the early intervention impact on arterial stiffness and pulse wave velocity (PWV) independent of its blood-pressure-(BP) lowering effect in mild hypertensive patients. Methods This single-center, single-arm, open-label, prospective, Phase IV study recruited patients with mild hypertension and increased PWV from December 2013 to December 2014 (N=138; age, 18–75 years; systolic blood pressure, 140–160 mmHg; diastolic BP, 90–100 mmHg; increased brachial–ankle pulse wave velocity [baPWV, ≥12 m/s]). Nifedipine GITS (30 mg/d) was administered for 24 weeks to achieve target BP of <140/90 mmHg. The dose was uptitrated at 60 mg/d in case of unsatisfactory BP reduction after 4 weeks. Primary study end point was the change in baPWV after nifedipine GITS treatment. Hemodynamic parameters (office BP, 24-hour ambulatory BP monitoring, and heart rate and adverse events) were evaluated at baseline and followed-up at 2, 4, 8, 12, 18, and 24 weeks. Results Majority of patients (n=117; 84.8%) completed the study. baPWV decreased significantly at 4 weeks compared with baseline (1,598.87±239.82 vs 1,500.89±241.15 cm/s, P<0.001), was stable at 12 weeks (1,482.24±215.14 cm/s, P<0.001), and remained steady through 24 weeks (1,472.58±205.01 cm/s, P<0.001). Office BP reduced from baseline to week 4 (154/95 vs 136/85 mmHg) and remained steady until 24 weeks. Nifedipine GITS significantly decreased 24-hour ambulatory BP monitoring (P<0.001) after 24 weeks from baseline. Mean arterial pressure and pulse pressure were lowered significantly after 4, 12, and 24 weeks of treatment (P<0.001). These changes in baPWV were significantly correlated with changes in systolic blood pressure, diastolic BP, and mean arterial pressure (P<0.05), but not with changes in pulse pressure (P>0.05). There were no other drug-related serious adverse events. Conclusion Nifedipine GITS was considerably effective in reducing baPWV and BP, indicating improvement in arterial stiffness as early as 4 weeks. PMID:27799740
Zhang, Man; Castaneda, Benjamin; Wu, Zhe; Nigwekar, Priya; Joseph, Jean V.; Rubens, Deborah J.; Parker, Kevin J.
2007-01-01
Biomechanical properties of soft tissues are important for a wide range of medical applications, such as surgical simulation and planning and detection of lesions by elasticity imaging modalities. Currently, the data in the literature is limited and conflicting. Furthermore, to assess the biomechanical properties of living tissue in vivo, reliable imaging-based estimators must be developed and verified. For these reasons we developed and compared two independent quantitative methods – crawling wave estimator (CRE) and mechanical measurement (MM) for soft tissue characterization. The CRE method images shear wave interference patterns from which the shear wave velocity can be determined and hence the Young’s modulus can be obtained. The MM method provides the complex Young’s modulus of the soft tissue from which both elastic and viscous behavior can be extracted. This article presents the systematic comparison between these two techniques on the measurement of gelatin phantom, veal liver, thermal-treated veal liver, and human prostate. It was observed that the Young’s moduli of liver and prostate tissues slightly increase with frequency. The experimental results of the two methods are highly congruent, suggesting CRE and MM methods can be reliably used to investigate viscoelastic properties of other soft tissues, with CRE having the advantages of operating in nearly real time and in situ. PMID:17604902
NASA Astrophysics Data System (ADS)
Best, Robert W.; Urbanus, Wim H.; Verhoeven, Toon (A.)G. A.; Jerby, Eli; Ganzel, Ronit
1993-07-01
A 1 MW cw 200 GHz tunable efficient free electron maser is being designed at the FOM Institute for application in magnetic fusion research. In this paper several waveguide types are considered, including open waveguides. Computer simulations of the amplification and guiding of the mm wave in the undulator are reported. The simulation code is G3DH, written by E. Jerby, which solves a matrix dispersion relation. Gain vs frequency curves are shown. Efficiency calculations indicate that some tapering is needed to reach the desired 1 MW mm wavepower. Simulations of a tapered undulator are presented by Caplan, and overview of the FOM FEM is given by Urbanus et al. at this conference.
Liang, S M; Chang, M H; Yang, Z Y
2014-01-01
This study aims at the design and development of electromagnetic-type intermittent shock wave generation in a liquid. The shock wave generated is focused at a focal point through an acoustic lens. This hardware device mainly consists of a full-wave bridge rectifier, 6 capacitors, a spark gap, and a flat coil. A metal disk is mounted in a liquid-filled tube and is placed in close proximity to the flat coil. Due to the repulsive force existing between the coil and disk shock waves are generated, while an eddy current is induced in the metal disk. Some components and materials associated with the device are also described. By increasing the capacitance content to enhance electric energy level, a highly focused pressure can be achieved at the focal point through an acoustic lens in order to lyse fat tissue. Focused pressures were measured at the focal point and its vicinity for different operation voltages. The designed shock wave generator with an energy intensity of 0.0016 mJ/mm(2) (at 4 kV) and 2000 firings or higher energy intensities with 1000 firings is found to be able to disrupt pig fat tissue.
Wideband Holographic Digital Recording and Reproduction. Phase IV.
1980-02-01
array of 128 acousto-optic ele- meats. The electrical energy is converted to acoustic waves within a glass crystal, so that when the light passes through...systems. An AO device is a block of transparent material (various types of glass , for example) through which we pass the laser beam that we want to...Clearance - .60 mm from cell Vignetting None None Glass Type Optional SF6 R ecord Mode Input Aperture 14 mm x 52mm 14mrm x 52rm Field Angle +12. 0
Pulsed Traveling-wave Quadrature Squeezing Using Quasi-phase Matched Lithium Niobate Crystals
NASA Astrophysics Data System (ADS)
Chen, Chao-Hsiang
Interests in generating higher quantum noise squeezing in order to develop methods to enhance optical measurement below the shot-noise limit in various applications has grown in recent years. The noise suppression from squeezing can improve the SNR in coherent optical systems when the returning signal power is weak, such as optical coherence tomography, LADAR, confocal microscopy and low-light coherent imaging. Unlike the generation of squeezing with a continuous wave, which is currently developed mainly for gravitational wave detection in LIGO project, the study of pulsed-traveling waves is focused on industrial, medical and other commercial interests. This dissertation presents the experimental results of pulsed traveling wave squeezing. The intention of the study is to explore the possibility of using quasi-phase matched crystals to generate the highest possible degree of quadrature squeezing. In order to achieve this goal, efforts to test the various effects from spatial Gaussian modes and relative beam waist placement for the second-harmonic pump were carried out in order to further the understanding of limiting factors to pulsed traveling wave squeezing. 20mm and 30mm-long periodically poled lithium noibate (PPLN) crystals were used in the experiment to generate a squeezed vacuum state. A maximum of 4.2+/-0.2dB quadrature squeezing has been observed, and the measured anti-squeezing exceeds 20dB.The phase sensitive amplification (PSA) gain and de-gain performance were also measured to compare the results of measured squeezing. The PPLN crystals can produce high conversion efficiency of second-harmonic generation (SHG) without a cavity. When a long PPLN crystal is used in a squeezer, the beam propagation in the nonlinear medium does not follow the characteristics in thin crystals. Instead, it is operated under the long-crystal criteria, which the crystal length is multiple times longer than the Rayleigh range of the injected beam i n the crystals. Quasi-phase matching was developed to overcome the limiting factor of both phase-mismatch and electric displacement walk off in second-harmonic generation. By using PPLN, the photorefractive damage threshold is the only limiting factor. For quantum noise squeezing with pulsed traveling-wave, the inhomogeneous nature of spatial and temporal modes are the constraining factors for further noise reduction.
Do Magnetic Fields Drive High-Energy Explosive Transients?
NASA Astrophysics Data System (ADS)
Mundell, Carole
2017-10-01
I will review the current state-of-the-art in real-time, rapid response optical imaging and polarimetric followup of transient sources such as Gamma Ray Bursts. I will interpret current results within the context of the external shock model and present predictions for future mm- and cm-wave radio observatories. Recent observational results from new radio pilot studies will also be presented.
Cong, Rui; Li, Jing; Wang, Xuejiao
2017-10-01
We determined the diagnostic performance of combinations of shear wave elastography (SWE) and B-mode ultrasound (US) in differentiating malignant from benign breast masses, and we investigated whether performance is affected by mass size. In this prospective study of 315 consecutive patients with 326 breast masses, US and SWE were performed before biopsy. Masses were categorized into two subgroups on the basis of mass size (≤15 mm and >15 mm), and the optimal thresholds for the SWE parameters were determined for each subgroup using receiver operating characteristic curves. The combination proposed here achieved an area under the receiver operating characteristic curve of 0.943, 95.00% sensitivity and 81.18% specificity, which approximated the diagnostic performance of US alone. The performance of the combinations using the subgroups' thresholds did not differ significantly from those based on the entire study group's thresholds, but the optimal thresholds were higher in the subgroup of larger masses. Further research is needed to determine whether mass size affects the performance of combinations of SWE and US. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Multilayered tissues model for wave propagation loss assessment in cochlear implants
NASA Astrophysics Data System (ADS)
Paun, Maria-Alexandra; Dehollain, Catherine
2017-05-01
In this paper, a study of the power loss attenuation of the plane wave travelling through the tissue layers, from the outside to the inside of the skull within a cochlear implant, is performed. Different implantation depths of the internal antenna from 10 to 30 mm are considered. To this purpose, the gain and attenuation in dB are studied. A multilayer tissue model is developed, consisting of mainly skin, mastoid bone and brain. An s-parameter analysis is also carried out, using loop antennas and simulated head tissue. Ansoft Ansys® HFSS software is used for electro-magnetic simulations of the antennas, placed in different types of human tissues. Smith charts for antenna placed in both skin and multi-tissue model are included.
NASA Astrophysics Data System (ADS)
Huan, Qiang; Miao, Hongchen; Li, Faxin
2018-02-01
Structural health monitoring (SHM) is of great importance for engineering structures as it may detect the early degradation and thus avoid life and financial loss. Guided wave based inspection is very useful in SHM due to its capability for long distance and wide range monitoring. The fundamental shear horizontal (SH0) wave based method should be most promising since SH0 is the unique non-dispersive wave mode in plate-like structures. In this work, a sparse array SHM system based on omnidirectional SH wave piezoelectric transducers (OSH-PT) was proposed and the multi data fusion method was used for defect inspection in a 2 mm thick aluminum plate. Firstly, the performances of three types OSH-PTs was comprehensively compared and the thickness-poled d15 mode OSH-PT used in this work was demonstrated obviously superior to the other two. Then, the signal processing method and imaging algorithm for this SHM system was presented. Finally, experiments were carried out to examine the performance of the proposed SHM system in defect localization and imaging. Results indicated that this SHM system can locate a through hole as small as 0.12λ (4 mm) in diameter (where λ is the wavelength corresponding to the central operation frequency) under frequencies from 90 to 150 kHz. It can also locate multiple defects accurately based on the baseline subtraction method. Obviously, this SHM system can detect larger areas with sparse sensors because of the adopted single mode, non-dispersive and low frequency SH0 wave which can propagate long distance with small attenuation. Considering its good performances, simple data processing and sparse array, this SH0 wave-based SHM system is expected to greatly promote the applications of guided wave inspection.
Said, Salah AM; Bloo, Rene; de Nooijer, Ramon; Slootweg, Andries
2015-01-01
AIM: To describe the electrocardiographic (ECG) phenomena characterized by T-wave inversion in the precordial leads in adults and to highlight its differential diagnosis. METHODS: A retrospective chart review of 8 adult patients who were admitted with ECG T-wave inversion in the anterior chest leads with or without prolongation of corrected QT (QTc) interval. They had different clinical conditions. Each patient underwent appropriate clinical assessment including investigation for myocardial involvement. Single and multimodality non-invasive, semi-invasive and invasive diagnostic approach were used to ascertain the diagnosis. The diagnostic assessment included biochemical investigation, cardiac and abdominal ultrasound, cerebral and chest computed tomography, nuclear medicine and coronary angiography. RESULTS: Eight adult subjects (5 females) with a mean age of 66 years (range 51 to 82) are analyzed. The etiology of T-wave inversion in the precordial leads were diverse. On admission, all patients had normal blood pressure and the ECG showed sinus rhythm. Five patients showed marked prolongation of the QTc interval. The longest QTc interval (639 ms) was found in the patient with pheochromocytoma. Giant T-wave inversion (≥ 10 mm) was found in pheochromocytoma followed by electroconvulsive therapy and finally ischemic heart disease. The deepest T-wave was measured in lead V3 (5 ×). In 3 patients presented with mild T-wave inversion (patients 1, 5 and 4 mm), the QTc interval was not prolonged (432, 409 and 424 msec), respectively. CONCLUSION: T-wave inversion associated with or without QTc prolongation requires meticulous history taking, physical examination and tailored diagnostic modalities to reach rapid and correct diagnosis to establish appropriate therapeutic intervention. PMID:25717356
Elastic wave induced by friction as a signature of human skin ageing and gender effect.
Djaghloul, M; Morizot, F; Zahouani, H
2016-08-01
In this work, we propose an innovative approach based on a rotary tribometer coupled with laser velocimetry for measuring the elastic wave propagation on the skin. The method is based on a dynamic contact with the control of the normal force (Fn ), the contact length and speed. During the test a quantification of the friction force is produced. The elastic wave generated by friction is measured at the surface of the skin 35 mm from the source of friction exciter. In order to quantify the spectral range and the energy property of the wave generated, we have used laser velocimetry whose spot laser diameter is 120 μm, which samples the elastic wave propagation at a frequency which may reach 100 kHz. In this configuration, the speaker is the friction exciter and the listener the laser velocimetry. In order to perform non-invasive friction tests, the normal stress has been set to 0.3 N and the rotary velocity to 3 revolutions per second, which involves a sliding velocity of 63 mm/s. This newly developed innovative tribometer has been used for the analysis of the elastic wave propagation induced by friction on human skin during chronological ageing and gender effect. Measurements in vivo have been made on 60 healthy men and women volunteers, aged from 25 to 70. The results concerning the energy of the elastic wave signature induced by friction show a clear difference between the younger and older groups in the range of a low band of frequencies (0-200 Hz). The gender effect was marked by a 20% decrease in the energy of elastic wave propagation in the female group. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Lansel, N; Niemeyer, G
1997-04-01
To investigate the short-term effects of fast-acting insulin on the electroretinogram-b-wave, optic nerve response, standing potential, and flow rate in the arterially perfused cat eye under normal conditions and during low glucose levels. Enucleated cat eyes were perfused with a glucose- and insulin-free tissue culture medium, to which glucose was applied at normal (5.5 mM) and reduced (2 and 1 mM) concentrations. Photic stimulation was performed in the rod-matched intensity range before, during, and after insulin application at postprandial (5 ng/ml) and at 10 and 20 x higher concentrations. Insulin failed to affect retinal signals at normal glucose levels. However, insulin enhanced the low glucose-induced decrease in rod-driven b-wave amplitude (P < 0.05 at 2 mM; P < 0.01 at 1 mM) without affecting the corresponding changes in the optic nerve response. The standing potential increased by as much as 0.75 mV in response to insulin. The perfusate flow rate was not altered by insulin. Insulin was not required for normal retinal function as observed during 10 hours of perfusion. The differential responsiveness to insulin under low glucose of the b-wave versus the optic nerve response is thought to reflect suppression of glucose use by Müller (glial) cells rather than neuromodulation, as the neuronal optic nerve response is unaffected. The postulated insulin sensitivity of Müller cells (changes in b-wave amplitude) indicates a possible difference in the mechanism of glucose metabolism of glia versus neurons. The electrophysiological effect of insulin under low glucose suggests its passage across the blood-retina barrier. The increase in the standing potential is likely to be a receptor-mediated retinal pigment epithelium effect. These results provide evidence in the retina for the reported multifunctional nature of the insulin receptor.
NASA Astrophysics Data System (ADS)
Li, Liuxia; Qian, Dun; Zou, Xiaobing; Wang, Xinxin
2018-05-01
The shock waves generated by an underwater electrical wire explosion were investigated. A microsecond time-scale pulsed current source was used to trigger the electrical explosion of copper wires with a length of 5 cm and a diameter of 200 μm. The energy-storage capacitor was charged to a relatively low energy so that the energy deposited onto the wire was not large enough to fully vaporize the whole wire. Two shock waves were recorded with a piezoelectric gauge that was located at a position of 100 mm from the exploding wire. The first and weak shock wave was confirmed to be the contribution from wire melting, while the second and stronger shock wave was the contribution from wire vaporization. The phenomenon whereby the first shock wave generated by melting being overtaken by the shock wave due to vaporization was observed.
Size and location of defects at the coupling interface affect lithotripter performance.
Li, Guangyan; Williams, James C; Pishchalnikov, Yuri A; Liu, Ziyue; McAteer, James A
2012-12-01
Study Type--Therapy (case series) Level of Evidence 4. What's known on the subject? and What does the study add? In shock wave lithotripsy air pockets tend to get caught between the therapy head of the lithotripter and the skin of the patient. Defects at the coupling interface hinder the transmission of shock wave energy into the body, reducing the effectiveness of treatment. This in vitro study shows that ineffective coupling not only blocks the transmission of acoustic pulses but also alters the properties of shock waves involved in the mechanisms of stone breakage, with the effect dependent on the size and location of defects at the coupling interface. • To determine how the size and location of coupling defects caught between the therapy head of a lithotripter and the skin of a surrogate patient (i.e. the acoustic window of a test chamber) affect the features of shock waves responsible for stone breakage. • Model defects were placed in the coupling gel between the therapy head of a Dornier Compact-S electromagnetic lithotripter (Dornier MedTech, Kennesaw, GA, USA) and the Mylar (biaxially oriented polyethylene terephthalate) (DuPont Teijin Films, Chester, VA, USA) window of a water-filled coupling test system. • A fibre-optic probe hydrophone was used to measure acoustic pressures and map the lateral dimensions of the focal zone of the lithotripter. • The effect of coupling conditions on stone breakage was assessed using gypsum model stones. • Stone breakage decreased in proportion to the area of the coupling defect; a centrally located defect blocking only 18% of the transmission area reduced stone breakage by an average of almost 30%. • The effect on stone breakage was greater for defects located on-axis and decreased as the defect was moved laterally; an 18% defect located near the periphery of the coupling window (2.0 cm off-axis) reduced stone breakage by only ~15% compared to when coupling was completely unobstructed. • Defects centred within the coupling window acted to narrow the focal width of the lithotripter; an 8.2% defect reduced the focal width ~30% compared to no obstruction (4.4 mm vs 6.5 mm). • Coupling defects located slightly off centre disrupted the symmetry of the acoustic field; an 18% defect positioned 1.0 cm off-axis shifted the focus of maximum positive pressure ~1.0 mm laterally. • Defects on and off-axis imposed a significant reduction in the energy density of shock waves across the focal zone. • In addition to blocking the transmission of shock-wave energy, coupling defects also disrupt the properties of shock waves that play a role in stone breakage, including the focal width of the lithotripter and the symmetry of the acoustic field • The effect is dependent on the size and location of defects, with defects near the centre of the coupling window having the greatest effect. • These data emphasize the importance of eliminating air pockets from the coupling interface, particularly defects located near the centre of the coupling window. © 2012 BJU INTERNATIONAL.
NASA Astrophysics Data System (ADS)
Penna, N. T.; Morales Maqueda, M.; Williams, S. D.; Foden, P.; Martin, I.; Pugh, J.
2013-12-01
We report on a first deployment of a GNSS Wave Glider designed for precise, unmanned, autonomous, mobile self-propelled sea level and sea state measurement in the open ocean. The Wave Glider, equipped with a dual frequency GPS+GLONASS receiver, was deployed in Loch Ness, Scotland, autonomously travelling 32 km in a north-easterly direction along the length of the loch in 26 hours, propelled by energy generated from waves of typical amplitude only 100-150 mm and frequency on the order 0.5-1 Hz. The Wave Glider GNSS data were analysed using a post-processed kinematic GPS+GLONASS precise point positioning (PPP) approach, which were quality controlled using double difference GPS kinematic processing with respect to onshore reference stations at either end of the loch. The PPP heights of the loch's surface revealed a clear geoid gradient of about 30 mm/km (i.e. just under 1 m over the whole length of the loch), very similar to both the EGM2008 and OSGM02 geoid models, demonstrating the potential use of a GNSS Wave Glider for marine geoid determination. After applying a low pass filter, the GNSS heights showed local deviations from both EGM2008 and OSGM02, potentially caused by omission errors or a lack of gravity data over Loch Ness. In addition to dual frequency GNSS data, the Wave Glider also recorded inclinometer data, bathymetry, and surface currents, which, in combination with tide gauge and wind data, were used to further control and interpret the GNSS time series.
Direct Measurement of Wave Kernels in Time-Distance Helioseismology
NASA Technical Reports Server (NTRS)
Duvall, T. L., Jr.
2006-01-01
Solar f-mode waves are surface-gravity waves which propagate horizontally in a thin layer near the photosphere with a dispersion relation approximately that of deep water waves. At the power maximum near 3 mHz, the wavelength of 5 Mm is large enough for various wave scattering properties to be observable. Gizon and Birch (2002,ApJ,571,966)h ave calculated kernels, in the Born approximation, for the sensitivity of wave travel times to local changes in damping rate and source strength. In this work, using isolated small magnetic features as approximate point-sourc'e scatterers, such a kernel has been measured. The observed kernel contains similar features to a theoretical damping kernel but not for a source kernel. A full understanding of the effect of small magnetic features on the waves will require more detailed modeling.
Impact of water drops on small targets
NASA Astrophysics Data System (ADS)
Rozhkov, A.; Prunet-Foch, B.; Vignes-Adler, M.
2002-10-01
The collision of water drops against small targets was studied experimentally by means of a high-speed photography technique. The drop impact velocity was about 3.5 m/s. Drop diameters were in the range of 2.8-4.0 mm. The target was a stainless steel disk of 3.9 mm diameter. The drop spread beyond the target like a central cap surrounded by a thin, slightly conical lamella bounded by a thicker rim. By mounting a small obstacle near the target, surface-tension driven Mach waves in the flowing lamella were generated, which are formally equivalent to the familiar compressibility driven Mach waves in gas dynamics. From the measurement of the Mach angle, the values of some flow parameters could be obtained as functions of time, which provided insight into the flow structure. The liquid flowed from the central cap to the liquid rim through the thin lamella at constant momentum flux. At a certain stage of the process, most of the liquid accumulated in the rim and the internal part of the lamella became metastable. In this situation, a rupture wave propagating through the metastable internal part of the lamella caused the rim to retract while forming outwardly directed secondary jets. The jets disintegrated into secondary droplets due to the Savart-Plateau-Rayleigh instability. Prior to the end of the retraction, an internal circular wave of rupture was formed. It originated at the target and then it propagated to meet the retracting rim. Their meeting resulted in a crown of tiny droplets. A theoretical analysis of the ejection process is proposed.
Design, Fabrication, and Testing of a TiN Ti TiN Trilayer KID Array for 3mm CMB Observations
NASA Technical Reports Server (NTRS)
Lowitz, A. E.; Brown, A. D.; Mikula, V.; Stevenson, T. R.; Timbie, P. T.; Wollack, E. J.
2016-01-01
Kinetic inductance detectors (KIDs) are a promising technology for astronomical observations over a wide range of wavelengths in the mm and sub-mm regime. Simple fabrication, in as little as one lithographic layer, and passive frequency-domain multiplexing, with readout of up to 1000 pixels on a single line with a single cold amplifier, make KIDs an attractive solution for high-pixel-count detector arrays. We are developing an array that optimizes KIDs for optical frequencies near 100GHz to expand their usefulness in mm-wave applications, with a particular focus on CMBB-mode measurement efforts in association with the QUBIC telescope. We have designed, fabricated, and tested a 20-pixel prototype array using a simple quasi lumped microstrip design and pulsed DC reactive magnetron-sputtered TiNTiTiN trilayer resonators, optimized for detecting 100GHz (3mm) signals. Here we present a discussion of design considerations for the array, as well as preliminary detector characterization measurements and results from a study of TiN trilayer properties.
Tou, Sandra P; Adin, Darcy B; Estrada, Amara H
2006-01-01
Systemic hypertension is likely underdiagnosed in veterinary medicine because systemic blood pressure is rarely measured. Systemic blood pressure can theoretically be estimated by echocardiography. According to the modified Bernoulli equation (PG = 4v(2)), mitral regurgitation (MR) velocity should approximate systolic left ventricular pressure (sLVP), and therefore systolic systemic blood pressure (sSBP) in the presence of a normal left atrial pressure (LAP) and the absence of aortic stenosis. The aim of this study was to evaluate the use of echocardiography to estimate sSBP by means of the Bernoulli equation. Systemic blood pressure can be estimated by echocardiography. Seventeen dogs with mild MR. No dogs had aortic or subaortic stenosis, and all had MR with a clear continuous-wave Doppler signal and a left atrial to aorta ratio of < or = 1.6. Five simultaneous, blinded continuous-wave measurements of maximum MR velocity (Vmax) and indirect sSBP measurements (by Park's Doppler) were obtained for each dog. Pressure gradient was calculated from Vmax by means of the Bernoulli equation, averaged, and added to an assumed LAP of 8 mm Hg to calculate sLVP. Calculated sLVP was significantly correlated with indirectly measured sSBP within a range of 121 to 218 mm Hg (P = .0002, r = .78). Mean +/- SD bias was 0.1 +/- 15.3 mm Hg with limits of agreement of -29.9 to 30.1 mm Hg. Despite the significant correlation, the wide limits of agreement between the methods hinder the clinical utility of echocardiographic estimation of blood pressure.
Cassimiro, Marcely; Romeiro, Kaline; Gominho, Luciana; de Almeida, Andressa; Silva, Lívia; Albuquerque, Diana
2018-01-01
The aim of this study was to analyse the potential occurrence of dentinal defects after root canal preparation using three engine-driven instruments. Eighty permanent mandibular incisors were selected. Twenty teeth did not undergo preparation, and the remaining teeth were divided into three groups ( n =20): Reciproc (REC) , ProTaper Next (PTN) and WaveOne Gold (WOG). The samples were dyed with methylene blue, sectioned perpendicularly to the long axis in 3-, 6- and 9-mm slices and were finally observed under a stereomicroscope (under 25×). The absence/presence of dentinal defects was documented by two blind observers. The data were analysed using Pearson's chi -squared test with a confidence level of 95% ( P =0.05). The time to prepare the samples was recorded, and the groups were compared using F -test (ANOVA). The control group did not present any defects, and the differences between the control and experimental groups were statistically significant ( P <0.05). WOG, PTN and REC caused microcracks on 60%, 33.33% and 18.33% of the samples, respectively. No significant differences between the groups in the 3-mm sections ( P =0.126) were observed. There were significant differences in the 6-mm ( P =0.042) and 9-mm sections ( P <0.001). When WOG and PTN were used to perform root canal preparation, a significant difference was found in the average time ( P =0.047). All the used instruments caused dentinal defects in the root dentin. All the instruments were used to perform the preparation with a similar average time.
Air-coupled ultrasonic through-transmission thickness measurements of steel plates.
Waag, Grunde; Hoff, Lars; Norli, Petter
2015-02-01
Non-destructive ultrasonic testing of steel structures provide valuable information in e.g. inspection of pipes, ships and offshore structures. In many practical applications, contact measurements are cumbersome or not possible, and air-coupled ultrasound can provide a solution. This paper presents air-coupled ultrasonic through-transmission measurements on a steel plate with thicknesses 10.15 mm; 10.0 mm; 9.8 mm. Ultrasound pulses were transmitted from a piezoelectric transducer at normal incidence, through the steel plate, and were received at the opposite side. The S1, A2 and A3 modes of the plate are excited, with resonance frequencies that depend on the material properties and the thickness of the plate. The results show that the resonances could be clearly identified after transmission through the steel plate, and that the frequencies of the resonances could be used to distinguish between the three plate thicknesses. The S1-mode resonance was observed to be shifted 10% down compared to a simple plane wave half-wave resonance model, while the A2 and S2 modes were found approximately at the corresponding plane-wave resonance frequencies. A model based on the angular spectrum method was used to predict the response of the through-transmission setup. This model included the finite aperture of the transmitter and receiver, and compressional and shear waves in the solid. The model predicts the frequencies of the observed modes of the plate to within 1%, including the down-shift of the S1-mode. Copyright © 2014 Elsevier B.V. All rights reserved.
Experimental investigation on the hydrodynamic performance of a wave energy converter
NASA Astrophysics Data System (ADS)
Zheng, Xiong-bo; Ma, Yong; Zhang, Liang; Jiang, Jin; Liu, Heng-xu
2017-06-01
Wave energy is an important type of marine renewable energy. A wave energy converter (WEC) moored with two floating bodies was developed in the present study. To analyze the dynamic performance of the WEC, an experimental device was designed and tested in a tank. The experiment focused on the factors which impact the motion and energy conversion performance of the WEC. Dynamic performance was evaluated by the relative displacements and velocities of the oscillator and carrier which served as the floating bodies of WEC. Four factors were tested, i.e. wave height, wave period, power take-off (PTO) damping, and mass ratio ( R M) of the oscillator and carrier. Experimental results show that these factors greatly affect the energy conversion performance, especially when the wave period matches R M and PTO damping. According to the results, we conclude that: (a) the maximization of the relative displacements and velocities leads to the maximization of the energy conversion efficiency; (b) the larger the wave height, the higher the energy conversion efficiency will be; (c) the relationships of energy conversion efficiency with wave period, PTO damping, and R M are nonlinear, but the maximum efficiency is obtained when these three factors are optimally matched. Experimental results demonstrated that the energy conversion efficiency reached the peak at 28.62% when the wave height was 120 mm, wave period was 1.0 s, R M was 0.21, and the PTO damping was corresponding to the resistance of 100 Ω.