Sample records for mobile eye tracker

  1. Do you see what I see? Mobile eye-tracker contextual analysis and inter-rater reliability.

    PubMed

    Stuart, S; Hunt, D; Nell, J; Godfrey, A; Hausdorff, J M; Rochester, L; Alcock, L

    2018-02-01

    Mobile eye-trackers are currently used during real-world tasks (e.g. gait) to monitor visual and cognitive processes, particularly in ageing and Parkinson's disease (PD). However, contextual analysis involving fixation locations during such tasks is rarely performed due to its complexity. This study adapted a validated algorithm and developed a classification method to semi-automate contextual analysis of mobile eye-tracking data. We further assessed inter-rater reliability of the proposed classification method. A mobile eye-tracker recorded eye-movements during walking in five healthy older adult controls (HC) and five people with PD. Fixations were identified using a previously validated algorithm, which was adapted to provide still images of fixation locations (n = 116). The fixation location was manually identified by two raters (DH, JN), who classified the locations. Cohen's kappa correlation coefficients determined the inter-rater reliability. The algorithm successfully provided still images for each fixation, allowing manual contextual analysis to be performed. The inter-rater reliability for classifying the fixation location was high for both PD (kappa = 0.80, 95% agreement) and HC groups (kappa = 0.80, 91% agreement), which indicated a reliable classification method. This study developed a reliable semi-automated contextual analysis method for gait studies in HC and PD. Future studies could adapt this methodology for various gait-related eye-tracking studies.

  2. Using Eye Trackers for Usability Evaluation of Health Information Technology: A Systematic Literature Review

    PubMed Central

    Yang, Yushi

    2015-01-01

    Background Eye-tracking technology has been used to measure human cognitive processes and has the potential to improve the usability of health information technology (HIT). However, it is still unclear how the eye-tracking method can be integrated with other traditional usability methodologies to achieve its full potential. Objective The objective of this study was to report on HIT evaluation studies that have used eye-tracker technology, and to envision the potential use of eye-tracking technology in future research. Methods We used four reference databases to initially identify 5248 related papers, which resulted in only 9 articles that met our inclusion criteria. Results Eye-tracking technology was useful in finding usability problems in many ways, but is still in its infancy for HIT usability evaluation. Limited types of HITs have been evaluated by eye trackers, and there has been a lack of evaluation research in natural settings. Conclusions More research should be done in natural settings to discover the real contextual-based usability problems of clinical and mobile HITs using eye-tracking technology with more standardized methodologies and guidance. PMID:27026079

  3. iTrack: instrumented mobile electrooculography (EOG) eye-tracking in older adults and Parkinson's disease.

    PubMed

    Stuart, Samuel; Hickey, Aodhán; Galna, Brook; Lord, Sue; Rochester, Lynn; Godfrey, Alan

    2017-01-01

    Detection of saccades (fast eye-movements) within raw mobile electrooculography (EOG) data involves complex algorithms which typically process data acquired during seated static tasks only. Processing of data during dynamic tasks such as walking is relatively rare and complex, particularly in older adults or people with Parkinson's disease (PD). Development of algorithms that can be easily implemented to detect saccades is required. This study aimed to develop an algorithm for the detection and measurement of saccades in EOG data during static (sitting) and dynamic (walking) tasks, in older adults and PD. Eye-tracking via mobile EOG and infra-red (IR) eye-tracker (with video) was performed with a group of older adults (n  =  10) and PD participants (n  =  10) (⩾50 years). Horizontal saccades made between targets set 5°, 10° and 15° apart were first measured while seated. Horizontal saccades were then measured while a participant walked and executed a 40° turn left and right. The EOG algorithm was evaluated by comparing the number of correct saccade detections and agreement (ICC 2,1 ) between output from visual inspection of eye-tracker videos and IR eye-tracker. The EOG algorithm detected 75-92% of saccades compared to video inspection and IR output during static testing, with fair to excellent agreement (ICC 2,1 0.49-0.93). However, during walking EOG saccade detection reduced to 42-88% compared to video inspection or IR output, with poor to excellent (ICC 2,1 0.13-0.88) agreement between methodologies. The algorithm was robust during seated testing but less so during walking, which was likely due to increased measurement and analysis error with a dynamic task. Future studies may consider a combination of EOG and IR for comprehensive measurement.

  4. iShadow: Design of a Wearable, Real-Time Mobile Gaze Tracker.

    PubMed

    Mayberry, Addison; Hu, Pan; Marlin, Benjamin; Salthouse, Christopher; Ganesan, Deepak

    2014-06-01

    Continuous, real-time tracking of eye gaze is valuable in a variety of scenarios including hands-free interaction with the physical world, detection of unsafe behaviors, leveraging visual context for advertising, life logging, and others. While eye tracking is commonly used in clinical trials and user studies, it has not bridged the gap to everyday consumer use. The challenge is that a real-time eye tracker is a power-hungry and computation-intensive device which requires continuous sensing of the eye using an imager running at many tens of frames per second, and continuous processing of the image stream using sophisticated gaze estimation algorithms. Our key contribution is the design of an eye tracker that dramatically reduces the sensing and computation needs for eye tracking, thereby achieving orders of magnitude reductions in power consumption and form-factor. The key idea is that eye images are extremely redundant, therefore we can estimate gaze by using a small subset of carefully chosen pixels per frame. We instantiate this idea in a prototype hardware platform equipped with a low-power image sensor that provides random access to pixel values, a low-power ARM Cortex M3 microcontroller, and a bluetooth radio to communicate with a mobile phone. The sparse pixel-based gaze estimation algorithm is a multi-layer neural network learned using a state-of-the-art sparsity-inducing regularization function that minimizes the gaze prediction error while simultaneously minimizing the number of pixels used. Our results show that we can operate at roughly 70mW of power, while continuously estimating eye gaze at the rate of 30 Hz with errors of roughly 3 degrees.

  5. iShadow: Design of a Wearable, Real-Time Mobile Gaze Tracker

    PubMed Central

    Mayberry, Addison; Hu, Pan; Marlin, Benjamin; Salthouse, Christopher; Ganesan, Deepak

    2015-01-01

    Continuous, real-time tracking of eye gaze is valuable in a variety of scenarios including hands-free interaction with the physical world, detection of unsafe behaviors, leveraging visual context for advertising, life logging, and others. While eye tracking is commonly used in clinical trials and user studies, it has not bridged the gap to everyday consumer use. The challenge is that a real-time eye tracker is a power-hungry and computation-intensive device which requires continuous sensing of the eye using an imager running at many tens of frames per second, and continuous processing of the image stream using sophisticated gaze estimation algorithms. Our key contribution is the design of an eye tracker that dramatically reduces the sensing and computation needs for eye tracking, thereby achieving orders of magnitude reductions in power consumption and form-factor. The key idea is that eye images are extremely redundant, therefore we can estimate gaze by using a small subset of carefully chosen pixels per frame. We instantiate this idea in a prototype hardware platform equipped with a low-power image sensor that provides random access to pixel values, a low-power ARM Cortex M3 microcontroller, and a bluetooth radio to communicate with a mobile phone. The sparse pixel-based gaze estimation algorithm is a multi-layer neural network learned using a state-of-the-art sparsity-inducing regularization function that minimizes the gaze prediction error while simultaneously minimizing the number of pixels used. Our results show that we can operate at roughly 70mW of power, while continuously estimating eye gaze at the rate of 30 Hz with errors of roughly 3 degrees. PMID:26539565

  6. Eye-Tracking Technology and the Dynamics of Natural Gaze Behavior in Sports: A Systematic Review of 40 Years of Research.

    PubMed

    Kredel, Ralf; Vater, Christian; Klostermann, André; Hossner, Ernst-Joachim

    2017-01-01

    Reviewing 60 studies on natural gaze behavior in sports, it becomes clear that, over the last 40 years, the use of eye-tracking devices has considerably increased. Specifically, this review reveals the large variance of methods applied, analyses performed, and measures derived within the field. The results of sub-sample analyses suggest that sports-related eye-tracking research strives, on the one hand, for ecologically valid test settings (i.e., viewing conditions and response modes), while on the other, for experimental control along with high measurement accuracy (i.e., controlled test conditions with high-frequency eye-trackers linked to algorithmic analyses). To meet both demands, some promising compromises of methodological solutions have been proposed-in particular, the integration of robust mobile eye-trackers in motion-capture systems. However, as the fundamental trade-off between laboratory and field research cannot be solved by technological means, researchers need to carefully weigh the arguments for one or the other approach by accounting for the respective consequences. Nevertheless, for future research on dynamic gaze behavior in sports, further development of the current mobile eye-tracking methodology seems highly advisable to allow for the acquisition and algorithmic analyses of larger amounts of gaze-data and further, to increase the explanatory power of the derived results.

  7. A multimodal interface to resolve the Midas-Touch problem in gaze controlled wheelchair.

    PubMed

    Meena, Yogesh Kumar; Cecotti, Hubert; Wong-Lin, KongFatt; Prasad, Girijesh

    2017-07-01

    Human-computer interaction (HCI) research has been playing an essential role in the field of rehabilitation. The usability of the gaze controlled powered wheelchair is limited due to Midas-Touch problem. In this work, we propose a multimodal graphical user interface (GUI) to control a powered wheelchair that aims to help upper-limb mobility impaired people in daily living activities. The GUI was designed to include a portable and low-cost eye-tracker and a soft-switch wherein the wheelchair can be controlled in three different ways: 1) with a touchpad 2) with an eye-tracker only, and 3) eye-tracker with soft-switch. The interface includes nine different commands (eight directions and stop) and integrated within a powered wheelchair system. We evaluated the performance of the multimodal interface in terms of lap-completion time, the number of commands, and the information transfer rate (ITR) with eight healthy participants. The analysis of the results showed that the eye-tracker with soft-switch provides superior performance with an ITR of 37.77 bits/min among the three different conditions (p<;0.05). Thus, the proposed system provides an effective and economical solution to the Midas-Touch problem and extended usability for the large population of disabled users.

  8. Remote gaze tracking system for 3D environments.

    PubMed

    Congcong Liu; Herrup, Karl; Shi, Bertram E

    2017-07-01

    Eye tracking systems are typically divided into two categories: remote and mobile. Remote systems, where the eye tracker is located near the object being viewed by the subject, have the advantage of being less intrusive, but are typically used for tracking gaze points on fixed two dimensional (2D) computer screens. Mobile systems such as eye tracking glasses, where the eye tracker are attached to the subject, are more intrusive, but are better suited for cases where subjects are viewing objects in the three dimensional (3D) environment. In this paper, we describe how remote gaze tracking systems developed for 2D computer screens can be used to track gaze points in a 3D environment. The system is non-intrusive. It compensates for small head movements by the user, so that the head need not be stabilized by a chin rest or bite bar. The system maps the 3D gaze points of the user onto 2D images from a scene camera and is also located remotely from the subject. Measurement results from this system indicate that it is able to estimate gaze points in the scene camera to within one degree over a wide range of head positions.

  9. Improving information recognition and performance of recycling chimneys.

    PubMed

    Durugbo, Christopher

    2013-01-01

    The aim of this study was to assess and improve how recyclers (individuals carrying out the task of recycling) make use of visual cues to carryout recycling tasks in relation to 'recycling chimneys' (repositories for recycled waste). An initial task analysis was conducted through an activity sampling study and an eye tracking experiment using a mobile eye tracker to capture fixations of recyclers during recycling tasks. Following data collection using the eye tracker, a set of recommendations for improving information representation were then identified using the widely researched skills, rules, knowledge framework, and for a comparative study to assess the performance of improved interfaces for recycling chimneys based on Ecological Interface Design principles. Information representation on recycling chimneys determines how we recycle waste. This study describes an eco-ergonomics-based approach to improve the design of interfaces for recycling chimneys. The results are valuable for improving the performance of waste collection processes in terms of minimising contamination and increasing the quantity of recyclables.

  10. Infant Eyes: A Window on Cognitive Development

    ERIC Educational Resources Information Center

    Aslin, Richard N.

    2012-01-01

    Eye-trackers suitable for use with infants are now marketed by several commercial vendors. As eye-trackers become more prevalent in infancy research, there is the potential for users to be unaware of dangers lurking "under the hood" if they assume the eye-tracker introduces no errors in measuring infants' gaze. Moreover, the influx of voluminous…

  11. Quiet eye gaze behavior of expert, and near-expert, baseball plate umpires.

    PubMed

    Millslagle, Duane G; Hines, Bridget B; Smith, Melissa S

    2013-02-01

    The quiet eye gaze behavior of 4 near-expert and 4 expert baseball umpires who called balls and strikes in simulated pitch-hit situations was assessed with a mobile eye cornea tracker system. Statistical analyses of the umpires' gaze behavior (fixation/pursuit tracking, saccades, and blinks)--onset, duration, offset, and frequency--were performed between and within 4 stages (pitcher's preparation, pitcher's delivery, ball in flight, and umpire call) by umpire's skill level. The results indicated that the quiet eye of expert umpires at onset of the pitcher's release point occurred earlier and was longer in duration than near-expert umpires. Expert expert umpires. The area outside the pitcher's ball release point may be the key environment cue for the behind-the-plate umpire.

  12. A laser-based eye-tracking system.

    PubMed

    Irie, Kenji; Wilson, Bruce A; Jones, Richard D; Bones, Philip J; Anderson, Tim J

    2002-11-01

    This paper reports on the development of a new eye-tracking system for noninvasive recording of eye movements. The eye tracker uses a flying-spot laser to selectively image landmarks on the eye and, subsequently, measure horizontal, vertical, and torsional eye movements. Considerable work was required to overcome the adverse effects of specular reflection of the flying-spot from the surface of the eye onto the sensing elements of the eye tracker. These effects have been largely overcome, and the eye-tracker has been used to document eye movement abnormalities, such as abnormal torsional pulsion of saccades, in the clinical setting.

  13. Analysis of the effects of Eye-Tracker performance on the pulse positioning errors during refractive surgery☆

    PubMed Central

    Arba-Mosquera, Samuel; Aslanides, Ioannis M.

    2012-01-01

    Purpose To analyze the effects of Eye-Tracker performance on the pulse positioning errors during refractive surgery. Methods A comprehensive model, which directly considers eye movements, including saccades, vestibular, optokinetic, vergence, and miniature, as well as, eye-tracker acquisition rate, eye-tracker latency time, scanner positioning time, laser firing rate, and laser trigger delay have been developed. Results Eye-tracker acquisition rates below 100 Hz correspond to pulse positioning errors above 1.5 mm. Eye-tracker latency times to about 15 ms correspond to pulse positioning errors of up to 3.5 mm. Scanner positioning times to about 9 ms correspond to pulse positioning errors of up to 2 mm. Laser firing rates faster than eye-tracker acquisition rates basically duplicate pulse-positioning errors. Laser trigger delays to about 300 μs have minor to no impact on pulse-positioning errors. Conclusions The proposed model can be used for comparison of laser systems used for ablation processes. Due to the pseudo-random nature of eye movements, positioning errors of single pulses are much larger than observed decentrations in the clinical settings. There is no single parameter that ‘alone’ minimizes the positioning error. It is the optimal combination of the several parameters that minimizes the error. The results of this analysis are important to understand the limitations of correcting very irregular ablation patterns.

  14. A Mobile Device Based Intervention to Reduce the Influence of Smoking Cues Among African American Cigarette Smokers

    DTIC Science & Technology

    2015-03-04

    lower rates of smoking cessation compared to Whites. African American smokers also live in communities that have a disproportionately high number of...Eye Tracker Screen Shots ................................................................... 139 Figure 6. Schematic Depiction of a PDA field...for African American smokers. African American smokers also live in communities that have a disproportionately high number of tobacco cues and

  15. One-kilohertz eye tracker and active intraoperative torsion detection in the NIDEK CXIII and Quest excimer lasers.

    PubMed

    Waring, George O

    2009-10-01

    To describe recent technological additions to the NIDEK CXIII and Quest excimer lasers. A summary article with data from previous published studies outlining the benefits of newer technology. The addition of a 1-kHz infrared eye tracker decreased the spread of laser spot placement from a mean of 228.79 microm without a tracker to 38.47 microm with the eye tracker. The addition of real-time torsion error correction produced a statistically significantly lower cylinder dispersion, mean manifest refractive cylinder, and error of angle postoperatively in eyes that underwent LASIK. The incorporation of an ultrahigh speed eye tracker and active cyclotorsion correction surpasses the minimal technology criteria required for accurate wavefront-based ablations. Copyright 2009, SLACK Incorporated.

  16. EyeTribe Tracker Data Accuracy Evaluation and Its Interconnection with Hypothesis Software for Cartographic Purposes.

    PubMed

    Popelka, Stanislav; Stachoň, Zdeněk; Šašinka, Čeněk; Doležalová, Jitka

    2016-01-01

    The mixed research design is a progressive methodological discourse that combines the advantages of quantitative and qualitative methods. Its possibilities of application are, however, dependent on the efficiency with which the particular research techniques are used and combined. The aim of the paper is to introduce the possible combination of Hypothesis with EyeTribe tracker. The Hypothesis is intended for quantitative data acquisition and the EyeTribe is intended for qualitative (eye-tracking) data recording. In the first part of the paper, Hypothesis software is described. The Hypothesis platform provides an environment for web-based computerized experiment design and mass data collection. Then, evaluation of the accuracy of data recorded by EyeTribe tracker was performed with the use of concurrent recording together with the SMI RED 250 eye-tracker. Both qualitative and quantitative results showed that data accuracy is sufficient for cartographic research. In the third part of the paper, a system for connecting EyeTribe tracker and Hypothesis software is presented. The interconnection was performed with the help of developed web application HypOgama. The created system uses open-source software OGAMA for recording the eye-movements of participants together with quantitative data from Hypothesis. The final part of the paper describes the integrated research system combining Hypothesis and EyeTribe.

  17. EyeTribe Tracker Data Accuracy Evaluation and Its Interconnection with Hypothesis Software for Cartographic Purposes

    PubMed Central

    Stachoň, Zdeněk; Šašinka, Čeněk; Doležalová, Jitka

    2016-01-01

    The mixed research design is a progressive methodological discourse that combines the advantages of quantitative and qualitative methods. Its possibilities of application are, however, dependent on the efficiency with which the particular research techniques are used and combined. The aim of the paper is to introduce the possible combination of Hypothesis with EyeTribe tracker. The Hypothesis is intended for quantitative data acquisition and the EyeTribe is intended for qualitative (eye-tracking) data recording. In the first part of the paper, Hypothesis software is described. The Hypothesis platform provides an environment for web-based computerized experiment design and mass data collection. Then, evaluation of the accuracy of data recorded by EyeTribe tracker was performed with the use of concurrent recording together with the SMI RED 250 eye-tracker. Both qualitative and quantitative results showed that data accuracy is sufficient for cartographic research. In the third part of the paper, a system for connecting EyeTribe tracker and Hypothesis software is presented. The interconnection was performed with the help of developed web application HypOgama. The created system uses open-source software OGAMA for recording the eye-movements of participants together with quantitative data from Hypothesis. The final part of the paper describes the integrated research system combining Hypothesis and EyeTribe. PMID:27087805

  18. Use of a Remote Eye-Tracker for the Analysis of Gaze during Treadmill Walking and Visual Stimuli Exposition.

    PubMed

    Serchi, V; Peruzzi, A; Cereatti, A; Della Croce, U

    2016-01-01

    The knowledge of the visual strategies adopted while walking in cognitively engaging environments is extremely valuable. Analyzing gaze when a treadmill and a virtual reality environment are used as motor rehabilitation tools is therefore critical. Being completely unobtrusive, remote eye-trackers are the most appropriate way to measure the point of gaze. Still, the point of gaze measurements are affected by experimental conditions such as head range of motion and visual stimuli. This study assesses the usability limits and measurement reliability of a remote eye-tracker during treadmill walking while visual stimuli are projected. During treadmill walking, the head remained within the remote eye-tracker workspace. Generally, the quality of the point of gaze measurements declined as the distance from the remote eye-tracker increased and data loss occurred for large gaze angles. The stimulus location (a dot-target) did not influence the point of gaze accuracy, precision, and trackability during both standing and walking. Similar results were obtained when the dot-target was replaced by a static or moving 2D target and "region of interest" analysis was applied. These findings foster the feasibility of the use of a remote eye-tracker for the analysis of gaze during treadmill walking in virtual reality environments.

  19. Tracker-assisted versus manual ablation zone centration in laser in situ keratomileusis for myopia and astigmatism.

    PubMed

    Pineros, Oscar E

    2002-01-01

    Eye tracker systems have been developed concomitantly with small scanning beams to theoretically reduce ablation zone decentration and for accurate registration of all the laser pulses on the cornea. The purpose of the study was to compare the tracker-assisted with the manual centration method. Twenty-five patients (48 eyes) with myopia and/or astigmatism had laser in situ keratomileusis (LASIK) between August 1998 and February 1999 with the Technolas 117C laser. Twenty patients (38 eyes, 80%) were available for follow-up at 3 months after surgery. Eyes were assigned randomly to one of two ablation zone centration methods: Group 1: Tracker-assisted (20 eyes), Group 2: Manual (18 eyes). Mean distance between the ablation zone center and the pupillary center in the tracker-assisted centration group was 0.55 +/- 0.30 mm (range, 0.10 to 1.4 mm), and in the manual centration group, 0.43 +/- 0.23 mm (range, 0.10 to 1.0 mm) (P = .177). There was no statistically significant difference in postoperative contrast sensitivity, glare, and Topographical Corneal Surface Regularity Index (SRI) between the two groups. We obtained good results with both centration methods. We did not find superiority of the tracker-assisted over manual regarding ablation zone centration, vision quality, or regularity of the ablation.

  20. Tracking Students' Cognitive Processes during Program Debugging--An Eye-Movement Approach

    ERIC Educational Resources Information Center

    Lin, Yu-Tzu; Wu, Cheng-Chih; Hou, Ting-Yun; Lin, Yu-Chih; Yang, Fang-Ying; Chang, Chia-Hu

    2016-01-01

    This study explores students' cognitive processes while debugging programs by using an eye tracker. Students' eye movements during debugging were recorded by an eye tracker to investigate whether and how high- and low-performance students act differently during debugging. Thirty-eight computer science undergraduates were asked to debug two C…

  1. Active eye-tracking improves LASIK results.

    PubMed

    Lee, Yuan-Chieh

    2007-06-01

    To study the advantage of active eye-tracking for photorefractive surgery. In a prospective, double-masked study, LASIK for myopia and myopic astigmatism was performed in 50 patients using the ALLEGRETTO WAVE version 1007. All patients received LASIK with full comprehension of the importance of fixation during the procedure. All surgical procedures were performed by a single surgeon. The eye-tracker was turned off in one group (n = 25) and kept on in another group (n = 25). Preoperatively and 3 months postoperatively, patients underwent a standard ophthalmic examination, which included comeal topography. In the patients treated with the eye-tracker off, all had uncorrected visual acuity (UCVA) of > or = 20/40 and 64% had > or = 20/20. Compared with the patients treated with the eye-tracker on, they had higher residual cylindrical astigmatism (P < .05). Those treated with the eye-tracker on achieved better UCVA and best spectacle-corrected visual acuity (P < .05). Spherical error and potential visual acuity (TMS-II) were not significantly different between the groups. The flying-spot system can achieve a fair result without active eye-tracking, but active eye-tracking helps improve the visual outcome and reduces postoperative cylindrical astigmatism.

  2. Which Eye Tracker is Right for Your Research Performance Evaluation of Several Cost Variant Eye Trackers

    DTIC Science & Technology

    2016-09-19

    REPORT TYPE 3. DATES COVERED (From - To) 21-10-16 Conference Proceedings 10/2015 – 03/2016 4. TITLE AND SUBTITLE Which eye tracker is right for...Force Research Laboratory 711th Human Performance Wing Airman Systems Directorate Warfighter Interface Division Applied Neuroscience Branch Wright...88ABW-2016-1334; Human Factors and Ergonomics Society 2016 Annual Meeting 19 – 23 Sept 2016 14. Though not often mentioned, the price point of many

  3. Head-mounted eye tracking: a new method to describe infant looking.

    PubMed

    Franchak, John M; Kretch, Kari S; Soska, Kasey C; Adolph, Karen E

    2011-01-01

    Despite hundreds of studies describing infants' visual exploration of experimental stimuli, researchers know little about where infants look during everyday interactions. The current study describes the first method for studying visual behavior during natural interactions in mobile infants. Six 14-month-old infants wore a head-mounted eye-tracker that recorded gaze during free play with mothers. Results revealed that infants' visual exploration is opportunistic and depends on the availability of information and the constraints of infants' own bodies. Looks to mothers' faces were rare following infant-directed utterances but more likely if mothers were sitting at infants' eye level. Gaze toward the destination of infants' hand movements was common during manual actions and crawling, but looks toward obstacles during leg movements were less frequent. © 2011 The Authors. Child Development © 2011 Society for Research in Child Development, Inc.

  4. A relationship between eye movement patterns and performance in a precognitive tracking task

    NASA Technical Reports Server (NTRS)

    Repperger, D. W.; Hartzell, E. J.

    1977-01-01

    Eye movements made by various subjects in the performance of a precognitive tracking task are studied. The tracking task persented by an antiaircraft artillery (AAA) simulator has an input forcing function represented by a deterministic aircraft fly-by. The performance of subjects is ranked by two metrics. Good, mediocre, and poor trackers are selected for analysis based on performance during the difficult segment of the tracking task and over replications. Using phase planes to characterize both the eye movement patterns and the displayed error signal, a simple metric is developed to study these patterns. Two characterizations of eye movement strategies are defined and quantified. Using these two types of eye strategies, two conclusions are obtained about good, mediocre, and poor trackers. First, the eye tracker who used a fixed strategy will consistently perform better. Secondly, the best fixed strategy is defined as a Crosshair Fixator.

  5. Eyes wide shut: implied social presence, eye tracking and attention.

    PubMed

    Risko, Evan F; Kingstone, Alan

    2011-02-01

    People often behave differently when they know they are being watched. Here, we report the first investigation of whether such social presence effects also influence looking behavior--a popular measure of attention allocation. We demonstrate that wearing an eye tracker, an implied social presence, leads individuals to avoid looking at particular stimuli. These results demonstrate that an implied social presence, here an eye tracker, can alter looking behavior. These data provide a new manipulation of social attention, as well as presenting a methodological challenge to researchers using eye tracking.

  6. Trajectory prediction of saccadic eye movements using a compressed exponential model

    PubMed Central

    Han, Peng; Saunders, Daniel R.; Woods, Russell L.; Luo, Gang

    2013-01-01

    Gaze-contingent display paradigms play an important role in vision research. The time delay due to data transmission from eye tracker to monitor may lead to a misalignment between the gaze direction and image manipulation during eye movements, and therefore compromise the contingency. We present a method to reduce this misalignment by using a compressed exponential function to model the trajectories of saccadic eye movements. Our algorithm was evaluated using experimental data from 1,212 saccades ranging from 3° to 30°, which were collected with an EyeLink 1000 and a Dual-Purkinje Image (DPI) eye tracker. The model fits eye displacement with a high agreement (R2 > 0.96). When assuming a 10-millisecond time delay, prediction of 2D saccade trajectories using our model could reduce the misalignment by 30% to 60% with the EyeLink tracker and 20% to 40% with the DPI tracker for saccades larger than 8°. Because a certain number of samples are required for model fitting, the prediction did not offer improvement for most small saccades and the early stages of large saccades. Evaluation was also performed for a simulated 100-Hz gaze-contingent display using the prerecorded saccade data. With prediction, the percentage of misalignment larger than 2° dropped from 45% to 20% for EyeLink and 42% to 26% for DPI data. These results suggest that the saccade-prediction algorithm may help create more accurate gaze-contingent displays. PMID:23902753

  7. Oculomotor control in children with fetal alcohol spectrum disorders assessed using a mobile eye-tracking laboratory.

    PubMed

    Green, C R; Mihic, A M; Brien, D C; Armstrong, I T; Nikkel, S M; Stade, B C; Rasmussen, C; Munoz, D P; Reynolds, J N

    2009-03-01

    Prenatal exposure to alcohol can result in a spectrum of adverse developmental outcomes, collectively termed fetal alcohol spectrum disorders (FASDs). This study evaluated deficits in sensory, motor and cognitive processing in children with FASD that can be identified using eye movement testing. Our study group was composed of 89 children aged 8-15 years with a diagnosis within the FASD spectrum [i.e. fetal alcohol syndrome (FAS), partial fetal alcohol syndrome (pFAS), and alcohol-related neurodevelopmental disorder (ARND)], and 92 controls. Subjects looked either towards (prosaccade) or away from (antisaccade) a peripheral target that appeared on a computer monitor, and eye movements were recorded with a mobile, video-based eye tracker. We hypothesized that: (i) differences in the magnitude of deficits in eye movement control exist across the three diagnostic subgroups; and (ii) children with FASD display a developmental delay in oculomotor control. Children with FASD had increased saccadic reaction times (SRTs), increased intra-subject variability in SRTs, and increased direction errors in both the prosaccade and antisaccade tasks. Although development was associated with improvements across tasks, children with FASD failed to achieve age-matched control levels of performance at any of the ages tested. Moreover, children with ARND had faster SRTs and made fewer direction errors in the antisaccade task than children with pFAS or FAS, although all subgroups were different from controls. Our results demonstrate that eye tracking can be used as an objective measure of brain injury in FASD, revealing behavioral deficits in all three diagnostic subgroups independent of facial dysmorphology.

  8. The impact of mobile phone use on where we look and how we walk when negotiating floor based obstacles.

    PubMed

    Timmis, Matthew A; Bijl, Herre; Turner, Kieran; Basevitch, Itay; Taylor, Matthew J D; van Paridon, Kjell N

    2017-01-01

    Pedestrians regularly engage with their mobile phone whilst walking. The current study investigated how mobile phone use affects where people look (visual search behaviour) and how they negotiate a floor based hazard placed along the walking path. Whilst wearing a mobile eye tracker and motion analysis sensors, participants walked up to and negotiated a surface height change whilst writing a text, reading a text, talking on the phone, or without a phone. Differences in gait and visual search behaviour were found when using a mobile phone compared to when not using a phone. Using a phone resulted in looking less frequently and for less time at the surface height change, which led to adaptations in gait by negotiating it in a manner consistent with adopting an increasingly cautious stepping strategy. When using a mobile phone, writing a text whilst walking resulted in the greatest adaptions in gait and visual search behaviour compared to reading a text and talking on a mobile phone. Findings indicate that mobile phone users were able to adapt their visual search behaviour and gait to incorporate mobile phone use in a safe manner when negotiating floor based obstacles.

  9. The impact of mobile phone use on where we look and how we walk when negotiating floor based obstacles

    PubMed Central

    Bijl, Herre; Turner, Kieran; Basevitch, Itay; Taylor, Matthew J. D.; van Paridon, Kjell N.

    2017-01-01

    Pedestrians regularly engage with their mobile phone whilst walking. The current study investigated how mobile phone use affects where people look (visual search behaviour) and how they negotiate a floor based hazard placed along the walking path. Whilst wearing a mobile eye tracker and motion analysis sensors, participants walked up to and negotiated a surface height change whilst writing a text, reading a text, talking on the phone, or without a phone. Differences in gait and visual search behaviour were found when using a mobile phone compared to when not using a phone. Using a phone resulted in looking less frequently and for less time at the surface height change, which led to adaptations in gait by negotiating it in a manner consistent with adopting an increasingly cautious stepping strategy. When using a mobile phone, writing a text whilst walking resulted in the greatest adaptions in gait and visual search behaviour compared to reading a text and talking on a mobile phone. Findings indicate that mobile phone users were able to adapt their visual search behaviour and gait to incorporate mobile phone use in a safe manner when negotiating floor based obstacles. PMID:28665942

  10. Scanning mid-IR laser apparatus with eye tracking for refractive surgery

    NASA Astrophysics Data System (ADS)

    Telfair, William B.; Yoder, Paul R., Jr.; Bekker, Carsten; Hoffman, Hanna J.; Jensen, Eric F.

    1999-06-01

    A robust, real-time, dynamic eye tracker has been integrated with the short pulse mid-infrared laser scanning delivery system previously described. This system employs a Q- switched Nd:YAG laser pumped optical parametric oscillator operating at 2.94 micrometers. Previous ablation studies on human cadaver eyes and in-vivo cat eyes demonstrated very smooth ablations with extremely low damage levels similar to results with an excimer. A 4-month healing study with cats indicated no adverse healing effects. In order to treat human eyes, the tracker is required because the eyes move during the procedure due to both voluntary and involuntary motions such as breathing, heartbeat, drift, loss of fixation, saccades and microsaccades. Eye tracking techniques from the literature were compared. A limbus tracking system was best for this application. Temporal and spectral filtering techniques were implemented to reduce tracking errors, reject stray light, and increase signal to noise ratio. The expanded-capability system (IRVision AccuScan 2000 Laser System) has been tested in the lab on simulated eye targets, glass eyes, cadaver eyes, and live human subjects. Circular targets ranging from 10-mm to 14-mm diameter were successfully tracked. The tracker performed beyond expectations while the system performed myopic photorefractive keratectomy procedures on several legally blind human subjects.

  11. Simulation of eye-tracker latency, spot size, and ablation pulse depth on the correction of higher order wavefront aberrations with scanning spot laser systems.

    PubMed

    Bueeler, Michael; Mrochen, Michael

    2005-01-01

    The aim of this theoretical work was to investigate the robustness of scanning spot laser treatments with different laser spot diameters and peak ablation depths in case of incomplete compensation of eye movements due to eye-tracker latency. Scanning spot corrections of 3rd to 5th Zernike order wavefront errors were numerically simulated. Measured eye-movement data were used to calculate the positioning error of each laser shot assuming eye-tracker latencies of 0, 5, 30, and 100 ms, and for the case of no eye tracking. The single spot ablation depth ranged from 0.25 to 1.0 microm and the spot diameter from 250 to 1000 microm. The quality of the ablation was rated by the postoperative surface variance and the Strehl intensity ratio, which was calculated after a low-pass filter was applied to simulate epithelial surface smoothing. Treatments performed with nearly ideal eye tracking (latency approximately 0) provide the best results with a small laser spot (0.25 mm) and a small ablation depth (250 microm). However, combinations of a large spot diameter (1000 microm) and a small ablation depth per pulse (0.25 microm) yield the better results for latencies above a certain threshold to be determined specifically. Treatments performed with tracker latencies in the order of 100 ms yield similar results as treatments done completely without eye-movement compensation. CONCWSIONS: Reduction of spot diameter was shown to make the correction more susceptible to eye movement induced error. A smaller spot size is only beneficial when eye movement is neutralized with a tracking system with a latency <5 ms.

  12. A new mapping function in table-mounted eye tracker

    NASA Astrophysics Data System (ADS)

    Tong, Qinqin; Hua, Xiao; Qiu, Jian; Luo, Kaiqing; Peng, Li; Han, Peng

    2018-01-01

    Eye tracker is a new apparatus of human-computer interaction, which has caught much attention in recent years. Eye tracking technology is to obtain the current subject's "visual attention (gaze)" direction by using mechanical, electronic, optical, image processing and other means of detection. While the mapping function is one of the key technology of the image processing, and is also the determination of the accuracy of the whole eye tracker system. In this paper, we present a new mapping model based on the relationship among the eyes, the camera and the screen that the eye gazed. Firstly, according to the geometrical relationship among the eyes, the camera and the screen, the framework of mapping function between the pupil center and the screen coordinate is constructed. Secondly, in order to simplify the vectors inversion of the mapping function, the coordinate of the eyes, the camera and screen was modeled by the coaxial model systems. In order to verify the mapping function, corresponding experiment was implemented. It is also compared with the traditional quadratic polynomial function. And the results show that our approach can improve the accuracy of the determination of the gazing point. Comparing with other methods, this mapping function is simple and valid.

  13. Simultaneous Recordings of Human Microsaccades and Drifts with a Contemporary Video Eye Tracker and the Search Coil Technique

    PubMed Central

    McCamy, Michael B.; Otero-Millan, Jorge; Leigh, R. John; King, Susan A.; Schneider, Rosalyn M.; Macknik, Stephen L.; Martinez-Conde, Susana

    2015-01-01

    Human eyes move continuously, even during visual fixation. These “fixational eye movements” (FEMs) include microsaccades, intersaccadic drift and oculomotor tremor. Research in human FEMs has grown considerably in the last decade, facilitated by the manufacture of noninvasive, high-resolution/speed video-oculography eye trackers. Due to the small magnitude of FEMs, obtaining reliable data can be challenging, however, and depends critically on the sensitivity and precision of the eye tracking system. Yet, no study has conducted an in-depth comparison of human FEM recordings obtained with the search coil (considered the gold standard for measuring microsaccades and drift) and with contemporary, state-of-the art video trackers. Here we measured human microsaccades and drift simultaneously with the search coil and a popular state-of-the-art video tracker. We found that 95% of microsaccades detected with the search coil were also detected with the video tracker, and 95% of microsaccades detected with video tracking were also detected with the search coil, indicating substantial agreement between the two systems. Peak/mean velocities and main sequence slopes of microsaccades detected with video tracking were significantly higher than those of the same microsaccades detected with the search coil, however. Ocular drift was significantly correlated between the two systems, but drift speeds were higher with video tracking than with the search coil. Overall, our combined results suggest that contemporary video tracking now approaches the search coil for measuring FEMs. PMID:26035820

  14. Workflows and individual differences during visually guided routine tasks in a road traffic management control room.

    PubMed

    Starke, Sandra D; Baber, Chris; Cooke, Neil J; Howes, Andrew

    2017-05-01

    Road traffic control rooms rely on human operators to monitor and interact with information presented on multiple displays. Past studies have found inconsistent use of available visual information sources in such settings across different domains. In this study, we aimed to broaden the understanding of observer behaviour in control rooms by analysing a case study in road traffic control. We conducted a field study in a live road traffic control room where five operators responded to incidents while wearing a mobile eye tracker. Using qualitative and quantitative approaches, we investigated the operators' workflow using ergonomics methods and quantified visual information sampling. We found that individuals showed differing preferences for viewing modalities and weighting of task components, with a strong coupling between eye and head movement. For the quantitative analysis of the eye tracking data, we propose a number of metrics which may prove useful to compare visual sampling behaviour across domains in future. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Look at my poster! Active gaze, preference and memory during a poster session.

    PubMed

    Foulsham, Tom; Kingstone, Alan

    2011-01-01

    In science, as in advertising, people often present information on a poster, yet little is known about attention during a poster session. A mobile eye-tracker was used to record participants' gaze during a mock poster session featuring a range of academic psychology posters. Participants spent the most time looking at introductions and conclusions. Larger posters were looked at for longer, as were posters rated more interesting (but not necessarily more aesthetically pleasing). Interestingly, gaze did not correlate with memory for poster details or liking, suggesting that attracting someone towards your poster may not be enough.

  16. Design of integrated eye tracker-display device for head mounted systems

    NASA Astrophysics Data System (ADS)

    David, Y.; Apter, B.; Thirer, N.; Baal-Zedaka, I.; Efron, U.

    2009-08-01

    We propose an Eye Tracker/Display system, based on a novel, dual function device termed ETD, which allows sharing the optical paths of the Eye tracker and the display and on-chip processing. The proposed ETD design is based on a CMOS chip combining a Liquid-Crystal-on-Silicon (LCoS) micro-display technology with near infrared (NIR) Active Pixel Sensor imager. The ET operation allows capturing the Near IR (NIR) light, back-reflected from the eye's retina. The retinal image is then used for the detection of the current direction of eye's gaze. The design of the eye tracking imager is based on the "deep p-well" pixel technology, providing low crosstalk while shielding the active pixel circuitry, which serves the imaging and the display drivers, from the photo charges generated in the substrate. The use of the ETD in the HMD Design enables a very compact design suitable for Smart Goggle applications. A preliminary optical, electronic and digital design of the goggle and its associated ETD chip and digital control, are presented.

  17. Legibility difference between e-books and paper books by using an eye tracker.

    PubMed

    Kim, Jung-Yong; Min, Seung-Nam; Subramaniyam, Murali; Cho, Young-Jin

    2014-01-01

    The aim of the study was to evaluate the difference in legibility between e-books and paper books by using an eye tracker. Eight male and eight female subjects free of eye disease participated in the experiment. The experiment was conducted using a 2 × 3 within-subject design. The book type (e-book, paper book) and font size (8 pt, 10 pt, 12 pt) were independent variables, and fixation duration time, saccade length, blink rate and subjective discomfort were dependent variables. In the results, all dependent variables showed that reading paper books provided a better experience than reading e-books did. These results indicate that the legibility of e-books needs further improvement, considering fixation duration time, saccade movement, eye fatigue, device and so on. This study evaluated the legibility difference between e-books and paper books from the viewpoint of readability, eye fatigue and subjective discomfort by using an eye tracker. The results showed that paper books provided a better experience than e-books. This indicates that the readability of e-books needs further improvement in relation to paper books.

  18. Young Children's Visual Attention to Environmental Print as Measured by Eye Tracker Analysis

    ERIC Educational Resources Information Center

    Neumann, Michelle M.; Acosta, Camillia; Neumann, David L.

    2014-01-01

    Environmental print, such as signs and product labels, consist of both print and contextual cues designed to attract the visual attention of the reader. However, contextual cues may draw young children's attention away from the print, thus questioning the value of environmental print in early reading development. Eye tracker technology was used to…

  19. [Reduction of decentration after LASIK using a modified eye tracker ring for the MEL-70 excimer laser].

    PubMed

    Schulze, S; Nietgen, G; Sekundo, W

    2004-07-01

    The aim of this study was to determine and compare the rate of eccentric laser ablation after LASIK depending on the eye tracker ring used. All LASIK treatments were carried out using the MEL-70 flying spot excimer laser (Zeiss-Meditec, Jena). The flap was produced using a Corneal Shaper trade mark or Hansatome trade mark Microkeratome (B and L Surgical, Heidelberg). Initially we used an 11 mm eye tracker ring without hinge protector. At the end of February 2001 this ring was replaced by a 10 mm and a 9.5 mm ring with built-in hinge protector. An additional modification was introduced by us: at 1 mm separations little teeth-like spikes were engraved into the eyeward side of the ring, thus stabilising the position of the ring on the globe and allowing free liquid to flow through the spaces between each spike. The built-in calibration system of the corneal topography (TMS 3, Tomey, Erlangen) from patients with a follow-up of one month or longer was used to determine the distance between the centre of the ablation zone from the fixation point. In group I patients (old ring) 42 eyes were treated. In 4 eyes ablation was perfect, in 21 eyes the ablation centre was located 0.1 to 0.49 mm from the fixation point, in 11 eyes 0.51 to 0.99 mm and in 5 eyes 1.1 to 1.49 mm whereas one eye showed a decentred ablation of 1.53 mm. In group II (new ring) 42 eyes were investigated also. In 11 eyes ablation was perfect, in 20 eyes the ablation centre was located 0.1 to 0.49 mm from the fixation point, in 10 eyes 0.5 to 0.99 mm and one eye had an eccentric ablation of 1.28 mm from the fixation point. The further development of our eye tracker ring for the MEL-70 laser considerably reduced the rate of decentred ablations. An enhanced grip of the ring onto the globe reduces a slow slide during the laser procedure.

  20. A holographic waveguide based eye tracker

    NASA Astrophysics Data System (ADS)

    Liu, Changgeng; Pazzucconi, Beatrice; Liu, Juan; Liu, Lei; Yao, Xincheng

    2018-02-01

    We demonstrated the feasibility of using holographic waveguide for eye tracking. A custom-built holographic waveguide, a 20 mm x 60 mm x 3 mm flat glass substrate with integrated in- and out-couplers, was used for the prototype development. The in- and out-couplers, photopolymer films with holographic fringes, induced total internal reflection in the glass substrate. Diffractive optical elements were integrated into the in-coupler to serve as an optical collimator. The waveguide captured images of the anterior segment of the eye right in front of it and guided the images to a processing unit distant from the eye. The vector connecting the pupil center (PC) and the corneal reflex (CR) of the eye was used to compute eye position in the socket. An eye model, made of a high quality prosthetic eye, was used prototype validation. The benchtop prototype demonstrated a linear relationship between the angular eye position and the PC/CR vector over a range of 60 horizontal degrees and 30 vertical degrees at a resolution of 0.64-0.69 degrees/pixel by simple pixel count. The uncertainties of the measurements at different angular positions were within 1.2 pixels, which indicated that the prototype exhibited a high level of repeatability. These results confirmed that the holographic waveguide technology could be a feasible platform for developing a wearable eye tracker. Further development can lead to a compact, see-through eye tracker, which allows continuous monitoring of eye movement during real life tasks, and thus benefits diagnosis of oculomotor disorders.

  1. Development of a digital mobile solar tracker

    NASA Astrophysics Data System (ADS)

    Baidar, S.; Kille, N.; Ortega, I.; Sinreich, R.; Thomson, D.; Hannigan, J.; Volkamer, R.

    2015-11-01

    We have constructed and deployed a fast digital solar tracker aboard a moving ground-based platform. The tracker consists of two rotating mirrors, a lens, an imaging camera, and a motion compensation system that provides the Euler angles of the mobile platform in real time. The tracker can be simultaneously coupled to UV-Vis and FTIR spectrometers making it a versatile tool to measure the absorption of trace gases using solar incoming radiation. The integrated system allows the tracker to operate autonomously while the mobile laboratory is in motion. Mobile direct sun Differential Optical Absorption Spectroscopy (mobile DS-DOAS) observations using this tracker were conducted during summer 2014 as part of the Front Range Photochemistry and Pollution Experiment (FRAPPE) in Colorado, USA. We demonstrate an angular precision of 0.052° (about 1/10 of the solar disk diameter) during research drives, and verify this tracking precision from measurements of the center to limb darkening (CLD, the changing appearance of Fraunhofer lines) in the mobile DS-DOAS spectra. The high photon flux from direct sun observation enables measurements of nitrogen dioxide (NO2) slant columns with high temporal resolution, and reveals spatial detail in the variations of NO2 vertical column densities (VCDs). The NO2 VCD from DS-DOAS is compared with a co-located MAX-DOAS instrument. Overall good agreement is observed amid a highly heterogeneous air mass.

  2. Development of a digital mobile solar tracker

    NASA Astrophysics Data System (ADS)

    Baidar, Sunil; Kille, Natalie; Ortega, Ivan; Sinreich, Roman; Thomson, David; Hannigan, James; Volkamer, Rainer

    2016-03-01

    We have constructed and deployed a fast digital solar tracker aboard a moving ground-based platform. The tracker consists of two rotating mirrors, a lens, an imaging camera, and a motion compensation system that provides the Euler angles of the mobile platform in real time. The tracker can be simultaneously coupled to UV-Vis and Fourier transform infrared spectrometers, making it a versatile tool to measure the absorption of trace gases using solar incoming radiation. The integrated system allows the tracker to operate autonomously while the mobile laboratory is in motion. Mobile direct sun differential optical absorption spectroscopy (mobile DS-DOAS) observations using this tracker were conducted during summer 2014 as part of the Front Range Air Pollution and Photochemistry Experiment (FRAPPE) in Colorado, USA. We demonstrate an angular precision of 0.052° (about 1/10 of the solar disk diameter) during research drives and verify this tracking precision from measurements of the center to limb darkening (CLD, the changing appearance of Fraunhofer lines) in the mobile DS-DOAS spectra. The high photon flux from direct sun observation enables measurements of nitrogen dioxide (NO2) slant columns with high temporal resolution and reveals spatial detail in the variations of NO2 vertical column densities (VCDs). The NO2 VCD from DS-DOAS is compared with a co-located MAX-DOAS instrument. Overall good agreement is observed amid a highly heterogeneous air mass.

  3. Comparing Eye Tracking with Electrooculography for Measuring Individual Sentence Comprehension Duration

    PubMed Central

    Müller, Jana Annina; Wendt, Dorothea; Kollmeier, Birger; Brand, Thomas

    2016-01-01

    The aim of this study was to validate a procedure for performing the audio-visual paradigm introduced by Wendt et al. (2015) with reduced practical challenges. The original paradigm records eye fixations using an eye tracker and calculates the duration of sentence comprehension based on a bootstrap procedure. In order to reduce practical challenges, we first reduced the measurement time by evaluating a smaller measurement set with fewer trials. The results of 16 listeners showed effects comparable to those obtained when testing the original full measurement set on a different collective of listeners. Secondly, we introduced electrooculography as an alternative technique for recording eye movements. The correlation between the results of the two recording techniques (eye tracker and electrooculography) was r = 0.97, indicating that both methods are suitable for estimating the processing duration of individual participants. Similar changes in processing duration arising from sentence complexity were found using the eye tracker and the electrooculography procedure. Thirdly, the time course of eye fixations was estimated with an alternative procedure, growth curve analysis, which is more commonly used in recent studies analyzing eye tracking data. The results of the growth curve analysis were compared with the results of the bootstrap procedure. Both analysis methods show similar processing durations. PMID:27764125

  4. Use of head-worn sensors to detect lapses in vigilance through the measurement of PERCLOS and cerebral blood flow velocity

    NASA Astrophysics Data System (ADS)

    McIntire, Lindsey K.; McKinley, R. Andy; Goodyear, Chuck; McIntire, John P.

    2017-05-01

    The purpose of this study is to determine the ability of an eye-tracker to detect changes in vigilance performance compared to the common method of using cerebral blood flow velocities (CBFV). Sixteen subjects completed this study. Each participant performed a 40-minute vigilance task while wearing an eye-tracker and a transcranial doppler (TCD) on each of four separate days. The results indicate that percentage of eye closure (PERCLOS) measured by the eye-tracker increased as vigilance performance declined and right CBFV as measured by the TCD decreased as performance declined. The results indicate that PERCLOS (left eye r=-.72 right eye r=-.67) more strongly correlated with changes in performance when compared to CBFV (r=.54). We conclude that PERCLOS, as measured by a head-worn eye tracking system, may serve as a compelling alternative (or supplemental) indicator of impending or concurrent performance declines in operational settings where sustained attention or vigilance is required. Such head-worn or perhaps even offbody oculometric sensor systems could potentially overcome some of the practical disadvantages inherent with TCD data collection for operational purposes. If portability and discomfort challenges with TCD can be overcome, both TCD and eye tracking might be advantageously combined for even greater performance monitoring than can be offered by any single device.

  5. Eye Movement Training and Suggested Gaze Strategies in Tunnel Vision - A Randomized and Controlled Pilot Study.

    PubMed

    Ivanov, Iliya V; Mackeben, Manfred; Vollmer, Annika; Martus, Peter; Nguyen, Nhung X; Trauzettel-Klosinski, Susanne

    2016-01-01

    Degenerative retinal diseases, especially retinitis pigmentosa (RP), lead to severe peripheral visual field loss (tunnel vision), which impairs mobility. The lack of peripheral information leads to fewer horizontal eye movements and, thus, diminished scanning in RP patients in a natural environment walking task. This randomized controlled study aimed to improve mobility and the dynamic visual field by applying a compensatory Exploratory Saccadic Training (EST). Oculomotor responses during walking and avoiding obstacles in a controlled environment were studied before and after saccade or reading training in 25 RP patients. Eye movements were recorded using a mobile infrared eye tracker (Tobii glasses) that measured a range of spatial and temporal variables. Patients were randomly assigned to two training conditions: Saccade (experimental) and reading (control) training. All subjects who first performed reading training underwent experimental training later (waiting list control group). To assess the effect of training on subjects, we measured performance in the training task and the following outcome variables related to daily life: Response Time (RT) during exploratory saccade training, Percent Preferred Walking Speed (PPWS), the number of collisions with obstacles, eye position variability, fixation duration, and the total number of fixations including the ones in the subjects' blind area of the visual field. In the saccade training group, RTs on average decreased, while the PPWS significantly increased. The improvement persisted, as tested 6 weeks after the end of the training. On average, the eye movement range of RP patients before and after training was similar to that of healthy observers. In both, the experimental and reading training groups, we found many fixations outside the subjects' seeing visual field before and after training. The average fixation duration was significantly shorter after the training, but only in the experimental training condition. We conclude that the exploratory saccade training was beneficial for RP patients and resulted in shorter fixation durations after the training. We also found a significant improvement in relative walking speed during navigation in a real-world like controlled environment.

  6. Eye Movement Training and Suggested Gaze Strategies in Tunnel Vision - A Randomized and Controlled Pilot Study

    PubMed Central

    Ivanov, Iliya V.; Mackeben, Manfred; Vollmer, Annika; Martus, Peter; Nguyen, Nhung X.; Trauzettel-Klosinski, Susanne

    2016-01-01

    Purpose Degenerative retinal diseases, especially retinitis pigmentosa (RP), lead to severe peripheral visual field loss (tunnel vision), which impairs mobility. The lack of peripheral information leads to fewer horizontal eye movements and, thus, diminished scanning in RP patients in a natural environment walking task. This randomized controlled study aimed to improve mobility and the dynamic visual field by applying a compensatory Exploratory Saccadic Training (EST). Methods Oculomotor responses during walking and avoiding obstacles in a controlled environment were studied before and after saccade or reading training in 25 RP patients. Eye movements were recorded using a mobile infrared eye tracker (Tobii glasses) that measured a range of spatial and temporal variables. Patients were randomly assigned to two training conditions: Saccade (experimental) and reading (control) training. All subjects who first performed reading training underwent experimental training later (waiting list control group). To assess the effect of training on subjects, we measured performance in the training task and the following outcome variables related to daily life: Response Time (RT) during exploratory saccade training, Percent Preferred Walking Speed (PPWS), the number of collisions with obstacles, eye position variability, fixation duration, and the total number of fixations including the ones in the subjects' blind area of the visual field. Results In the saccade training group, RTs on average decreased, while the PPWS significantly increased. The improvement persisted, as tested 6 weeks after the end of the training. On average, the eye movement range of RP patients before and after training was similar to that of healthy observers. In both, the experimental and reading training groups, we found many fixations outside the subjects' seeing visual field before and after training. The average fixation duration was significantly shorter after the training, but only in the experimental training condition. Conclusions We conclude that the exploratory saccade training was beneficial for RP patients and resulted in shorter fixation durations after the training. We also found a significant improvement in relative walking speed during navigation in a real-world like controlled environment. PMID:27351629

  7. The influence of crystalline lens accommodation on post-saccadic oscillations in pupil-based eye trackers.

    PubMed

    Nyström, Marcus; Andersson, Richard; Magnusson, Måns; Pansell, Tony; Hooge, Ignace

    2015-02-01

    It is well known that the crystalline lens (henceforth lens) can oscillate (or 'wobble') relative to the eyeball at the end of saccades. Recent research has proposed that such wobbling of the lens is a source of post-saccadic oscillations (PSOs) seen in data recorded by eye trackers that estimate gaze direction from the location of the pupil. Since the size of the lens wobbles increases with accommodative effort, one would predict a similar increase of PSO-amplitude in data recorded with a pupil based eye tracker. In four experiments, we investigated the role of lens accommodation on PSOs in a video-based eye tracker. In Experiment 1, we replicated previous results showing that PSO-amplitudes increase at near viewing distances (large vergence angles), when the lens is highly accommodated. In Experiment 2a, we manipulated the accommodative state of the lens pharmacologically using eye drops at a fixed viewing distance and found, in contrast to Experiment 1, no significant difference in PSO-amplitude related to the accommodative state of the lens. Finally, in Experiment 2b, the effect of vergence angle was investigated by comparing PSO-amplitudes at near and far while maintaining a fixed lens accommodation. Despite the pharmacologically fixed degree of accommodation, PSO-amplitudes were systematically larger in the near condition. In summary, PSOs cannot exhaustively be explained by lens wobbles. Possible confounds related to pupil size and eye-camera angle are investigated in Experiments 3 and 4, and alternative mechanisms behind PSOs are probed in the discussion. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Fixational eye movement: a negligible source of dynamic aberration.

    PubMed

    Mecê, Pedro; Jarosz, Jessica; Conan, Jean-Marc; Petit, Cyril; Grieve, Kate; Paques, Michel; Meimon, Serge

    2018-02-01

    To evaluate the contribution of fixational eye movements to dynamic aberration, 50 healthy eyes were examined with an original custom-built Shack-Hartmann aberrometer, running at a temporal frequency of 236Hz, with 22 lenslets across a 5mm pupil, synchronized with a 236Hz pupil tracker. A comparison of the dynamic behavior of the first 21 Zernike modes (starting from defocus) with and without digital pupil stabilization, on a 3.4s sequence between blinks, showed that the contribution of fixational eye movements to dynamic aberration is negligible. Therefore we highlighted the fact that a pupil tracker coupled to an Adaptive Optics Ophthalmoscope is not essential to achieve diffraction-limited resolution.

  9. Quiet eye training improves surgical knot tying more than traditional technical training: a randomized controlled study.

    PubMed

    Causer, Joe; Harvey, Adrian; Snelgrove, Ryan; Arsenault, Gina; Vickers, Joan N

    2014-08-01

    We examined the effectiveness of technical training (TT) and quiet eye training (QE) on the performance of one-handed square knot tying in surgical residents. Twenty surgical residents were randomly assigned to the 2 groups and completed pretest, training, retention, and transfer tests. Participants wore a mobile eye tracker that simultaneously recorded their gaze and hand movements. Dependent variables were knot tying performance (%), QE duration (%), number of fixations, total movement time (s), and hand movement phase time (s). The QE training group had significantly higher performance scores, a longer QE duration, fewer fixations, faster total knot tying times, and faster movement phase times compared with the TT group. The QE group maintained performance in the transfer test, whereas the TT group significantly decreased performance from retention to transfer. QE training significantly improved learning, retention, and transfer of surgical knot tying compared with a traditional technical approach. Both performance effectiveness (performance outcome) and movement efficiency (hand movement times) were improved using QE modeling, instruction, and feedback. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Measuring saccade peak velocity using a low-frequency sampling rate of 50 Hz.

    PubMed

    Wierts, Roel; Janssen, Maurice J A; Kingma, Herman

    2008-12-01

    During the last decades, small head-mounted video eye trackers have been developed in order to record eye movements. Real-time systems-with a low sampling frequency of 50/60 Hz-are used for clinical vestibular practice, but are generally considered not to be suited for measuring fast eye movements. In this paper, it is shown that saccadic eye movements, having an amplitude of at least 5 degrees, can, in good approximation, be considered to be bandwidth limited up to a frequency of 25-30 Hz. Using the Nyquist theorem to reconstruct saccadic eye movement signals at higher temporal resolutions, it is shown that accurate values for saccade peak velocities, recorded at 50 Hz, can be obtained, but saccade peak accelerations and decelerations cannot. In conclusion, video eye trackers sampling at 50/60 Hz are appropriate for detecting the clinical relevant saccade peak velocities in contrast to what has been stated up till now.

  11. Fixation stability of the upward gaze in patients with myasthenia gravis: an eye-tracker study

    PubMed Central

    Mihara, Miharu; Hayashi, Atsushi; Fujita, Kazuya; Kakeue, Ken; Tamura, Ryoi

    2017-01-01

    Objective To quantify fixation stability of the upward gaze in patients with myasthenia gravis (MG) using an eye tracker. Methods and analysis In this study, 21 normal subjects, 5 patients with MG with diplopia, 5 patients with MG without diplopia and 6 patients with superior oblique (SO) palsy were included. Subjects fixated on a target in the upward direction for 1 min. The horizontal (X) and vertical (Y) eye positions were recorded using an eye tracker. Fixation stability was first quantified using the bivariate contour ellipse areas (BCEA) of fixation points as an index of whole stability. Then, the SDs of the X and Y eye positions (SDX and SDY, respectively) were quantified as indices of directional stability, with the data divided into three 20 s fractions to detect temporal fixation fluctuation. Results BCEAs were larger in patients with MG (both with and without diplopia) than normal subjects and patients with SO palsy, without significant differences among the three 20 s fractions. Compared with normal subjects, SDXs were larger only in patients with MG with diplopia; SDYs were larger in both patients with MG with and without diplopia. In addition, SDYs in patients with MG with diplopia were larger than those in patients with MG without diplopia and patients with SO palsy. Furthermore, a significant difference among the three 20 s fractions was detected for SDYs in patients with MG with diplopia. Conclusion Patients with MG, especially those with diplopia, exhibit fixation instability in the upward gaze. Non-invasive quantification of fixation stability with an eye tracker is useful for precisely identifying MG-specific fatigue characteristics. Trial registration number UMIN000023468; pre-results. PMID:29354719

  12. Effects of aging on eye movements in the real world

    PubMed Central

    Dowiasch, Stefan; Marx, Svenja; Einhäuser, Wolfgang; Bremmer, Frank

    2015-01-01

    The effects of aging on eye movements are well studied in the laboratory. Increased saccade latencies or decreased smooth-pursuit gain are well established findings. The question remains whether these findings are influenced by the rather untypical environment of a laboratory; that is, whether or not they transfer to the real world. We measured 34 healthy participants between the age of 25 and 85 during two everyday tasks in the real world: (I) walking down a hallway with free gaze, (II) visual tracking of an earth-fixed object while walking straight-ahead. Eye movements were recorded with a mobile light-weight eye tracker, the EyeSeeCam (ESC). We find that age significantly influences saccade parameters. With increasing age, saccade frequency, amplitude, peak velocity, and mean velocity are reduced and the velocity/amplitude distribution as well as the velocity profile become less skewed. In contrast to laboratory results on smooth pursuit, we did not find a significant effect of age on tracking eye-movements in the real world. Taken together, age-related eye-movement changes as measured in the laboratory only partly resemble those in the real world. It is well-conceivable that in the real world additional sensory cues, such as head-movement or vestibular signals, may partially compensate for age-related effects, which, according to this view, would be specific to early motion processing. In any case, our results highlight the importance of validity for natural situations when studying the impact of aging on real-life performance. PMID:25713524

  13. Effects of aging on eye movements in the real world.

    PubMed

    Dowiasch, Stefan; Marx, Svenja; Einhäuser, Wolfgang; Bremmer, Frank

    2015-01-01

    The effects of aging on eye movements are well studied in the laboratory. Increased saccade latencies or decreased smooth-pursuit gain are well established findings. The question remains whether these findings are influenced by the rather untypical environment of a laboratory; that is, whether or not they transfer to the real world. We measured 34 healthy participants between the age of 25 and 85 during two everyday tasks in the real world: (I) walking down a hallway with free gaze, (II) visual tracking of an earth-fixed object while walking straight-ahead. Eye movements were recorded with a mobile light-weight eye tracker, the EyeSeeCam (ESC). We find that age significantly influences saccade parameters. With increasing age, saccade frequency, amplitude, peak velocity, and mean velocity are reduced and the velocity/amplitude distribution as well as the velocity profile become less skewed. In contrast to laboratory results on smooth pursuit, we did not find a significant effect of age on tracking eye-movements in the real world. Taken together, age-related eye-movement changes as measured in the laboratory only partly resemble those in the real world. It is well-conceivable that in the real world additional sensory cues, such as head-movement or vestibular signals, may partially compensate for age-related effects, which, according to this view, would be specific to early motion processing. In any case, our results highlight the importance of validity for natural situations when studying the impact of aging on real-life performance.

  14. Web Camera Based Eye Tracking to Assess Visual Memory on a Visual Paired Comparison Task.

    PubMed

    Bott, Nicholas T; Lange, Alex; Rentz, Dorene; Buffalo, Elizabeth; Clopton, Paul; Zola, Stuart

    2017-01-01

    Background: Web cameras are increasingly part of the standard hardware of most smart devices. Eye movements can often provide a noninvasive "window on the brain," and the recording of eye movements using web cameras is a burgeoning area of research. Objective: This study investigated a novel methodology for administering a visual paired comparison (VPC) decisional task using a web camera.To further assess this method, we examined the correlation between a standard eye-tracking camera automated scoring procedure [obtaining images at 60 frames per second (FPS)] and a manually scored procedure using a built-in laptop web camera (obtaining images at 3 FPS). Methods: This was an observational study of 54 clinically normal older adults.Subjects completed three in-clinic visits with simultaneous recording of eye movements on a VPC decision task by a standard eye tracker camera and a built-in laptop-based web camera. Inter-rater reliability was analyzed using Siegel and Castellan's kappa formula. Pearson correlations were used to investigate the correlation between VPC performance using a standard eye tracker camera and a built-in web camera. Results: Strong associations were observed on VPC mean novelty preference score between the 60 FPS eye tracker and 3 FPS built-in web camera at each of the three visits ( r = 0.88-0.92). Inter-rater agreement of web camera scoring at each time point was high (κ = 0.81-0.88). There were strong relationships on VPC mean novelty preference score between 10, 5, and 3 FPS training sets ( r = 0.88-0.94). Significantly fewer data quality issues were encountered using the built-in web camera. Conclusions: Human scoring of a VPC decisional task using a built-in laptop web camera correlated strongly with automated scoring of the same task using a standard high frame rate eye tracker camera.While this method is not suitable for eye tracking paradigms requiring the collection and analysis of fine-grained metrics, such as fixation points, built-in web cameras are a standard feature of most smart devices (e.g., laptops, tablets, smart phones) and can be effectively employed to track eye movements on decisional tasks with high accuracy and minimal cost.

  15. Analysis of eye-tracking experiments performed on a Tobii T60

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Banks, David C

    2008-01-01

    Commercial eye-gaze trackers have the potential to be an important tool for quantifying the benefits of new visualization techniques. The expense of such trackers has made their use relatively infrequent in visualization studies. As such, it is difficult for researchers to compare multiple devices obtaining several demonstration models is impractical in cost and time, and quantitative measures from real-world use are not readily available. In this paper, we present a sample protocol to determine the accuracy of a gaze-tacking device.

  16. TE-Tracker: systematic identification of transposition events through whole-genome resequencing.

    PubMed

    Gilly, Arthur; Etcheverry, Mathilde; Madoui, Mohammed-Amin; Guy, Julie; Quadrana, Leandro; Alberti, Adriana; Martin, Antoine; Heitkam, Tony; Engelen, Stefan; Labadie, Karine; Le Pen, Jeremie; Wincker, Patrick; Colot, Vincent; Aury, Jean-Marc

    2014-11-19

    Transposable elements (TEs) are DNA sequences that are able to move from their location in the genome by cutting or copying themselves to another locus. As such, they are increasingly recognized as impacting all aspects of genome function. With the dramatic reduction in cost of DNA sequencing, it is now possible to resequence whole genomes in order to systematically characterize novel TE mobilization in a particular individual. However, this task is made difficult by the inherently repetitive nature of TE sequences, which in some eukaryotes compose over half of the genome sequence. Currently, only a few software tools dedicated to the detection of TE mobilization using next-generation-sequencing are described in the literature. They often target specific TEs for which annotation is available, and are only able to identify families of closely related TEs, rather than individual elements. We present TE-Tracker, a general and accurate computational method for the de-novo detection of germ line TE mobilization from re-sequenced genomes, as well as the identification of both their source and destination sequences. We compare our method with the two classes of existing software: specialized TE-detection tools and generic structural variant (SV) detection tools. We show that TE-Tracker, while working independently of any prior annotation, bridges the gap between these two approaches in terms of detection power. Indeed, its positive predictive value (PPV) is comparable to that of dedicated TE software while its sensitivity is typical of a generic SV detection tool. TE-Tracker demonstrates the benefit of adopting an annotation-independent, de novo approach for the detection of TE mobilization events. We use TE-Tracker to provide a comprehensive view of transposition events induced by loss of DNA methylation in Arabidopsis. TE-Tracker is freely available at http://www.genoscope.cns.fr/TE-Tracker . We show that TE-Tracker accurately detects both the source and destination of novel transposition events in re-sequenced genomes. Moreover, TE-Tracker is able to detect all potential donor sequences for a given insertion, and can identify the correct one among them. Furthermore, TE-Tracker produces significantly fewer false positives than common SV detection programs, thus greatly facilitating the detection and analysis of TE mobilization events.

  17. Impact of experience when using the Rapid Upper Limb Assessment to assess postural risk in children using information and communication technologies.

    PubMed

    Chen, Janice D; Falkmer, Torbjörn; Parsons, Richard; Buzzard, Jennifer; Ciccarelli, Marina

    2014-05-01

    The Rapid Upper Limb Assessment (RULA) is an observation-based screening tool that has been used to assess postural risks of children in school settings. Studies using eye-tracking technology suggest that visual search strategies are influenced by experience in the task performed. This study investigated if experience in postural risk assessments contributed to differences in outcome scores on the RULA and the visual search strategies utilized. While wearing an eye-tracker, 16 student occupational therapists and 16 experienced occupational therapists used the RULA to assess 11 video scenarios of a child using different mobile information and communication technologies (ICT) in the home environment. No significant differences in RULA outcome scores, and no conclusive differences in visual search strategies between groups were found. RULA can be used as a screening tool for postural risks following a short training session regardless of the assessor's experience in postural risk assessments. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  18. MR-Compatible Integrated Eye Tracking System

    DTIC Science & Technology

    2016-03-10

    SECURITY CLASSIFICATION OF: This instrumentation grant was used to purchase state-of-the-art, high-resolution video eye tracker that can be used to...P.O. Box 12211 Research Triangle Park, NC 27709-2211 video eye tracking, eye movments, visual search; camouflage-breaking REPORT DOCUMENTATION PAGE...Report: MR-Compatible Integrated Eye Tracking System Report Title This instrumentation grant was used to purchase state-of-the-art, high-resolution video

  19. Depression Screening Using Daily Mental-Health Ratings from a Smartphone Application for Breast Cancer Patients.

    PubMed

    Kim, Junetae; Lim, Sanghee; Min, Yul Ha; Shin, Yong-Wook; Lee, Byungtae; Sohn, Guiyun; Jung, Kyung Hae; Lee, Jae-Ho; Son, Byung Ho; Ahn, Sei Hyun; Shin, Soo-Yong; Lee, Jong Won

    2016-08-04

    Mobile mental-health trackers are mobile phone apps that gather self-reported mental-health ratings from users. They have received great attention from clinicians as tools to screen for depression in individual patients. While several apps that ask simple questions using face emoticons have been developed, there has been no study examining the validity of their screening performance. In this study, we (1) evaluate the potential of a mobile mental-health tracker that uses three daily mental-health ratings (sleep satisfaction, mood, and anxiety) as indicators for depression, (2) discuss three approaches to data processing (ratio, average, and frequency) for generating indicator variables, and (3) examine the impact of adherence on reporting using a mobile mental-health tracker and accuracy in depression screening. We analyzed 5792 sets of daily mental-health ratings collected from 78 breast cancer patients over a 48-week period. Using the Patient Health Questionnaire-9 (PHQ-9) as the measure of true depression status, we conducted a random-effect logistic panel regression and receiver operating characteristic (ROC) analysis to evaluate the screening performance of the mobile mental-health tracker. In addition, we classified patients into two subgroups based on their adherence level (higher adherence and lower adherence) using a k-means clustering algorithm and compared the screening accuracy between the two groups. With the ratio approach, the area under the ROC curve (AUC) is 0.8012, indicating that the performance of depression screening using daily mental-health ratings gathered via mobile mental-health trackers is comparable to the results of PHQ-9 tests. Also, the AUC is significantly higher (P=.002) for the higher adherence group (AUC=0.8524) than for the lower adherence group (AUC=0.7234). This result shows that adherence to self-reporting is associated with a higher accuracy of depression screening. Our results support the potential of a mobile mental-health tracker as a tool for screening for depression in practice. Also, this study provides clinicians with a guideline for generating indicator variables from daily mental-health ratings. Furthermore, our results provide empirical evidence for the critical role of adherence to self-reporting, which represents crucial information for both doctors and patients.

  20. Septic safe interactions with smart glasses in health care.

    PubMed

    Czuszynski, K; Ruminski, J; Kocejko, T; Wtorek, J

    2015-08-01

    In this paper, septic safe methods of interaction with smart glasses, due to the health care environment applications consideration, are presented. The main focus is on capabilities of an optical, proximity-based gesture sensor and eye-tracker input systems. The design of both interfaces is being adapted to the open smart glasses platform that is being developed under the eGlasses project. Preliminary results obtained from the proximity sensor show that the recognition of different static and dynamic hand gestures is promising. The experiments performed for the eye-tracker module shown the possibility of interaction with simple Graphical User Interface provided by the near-to-eye display. Research leads to the conclusion of attractiveness of collaborative interfaces for interaction with smart glasses.

  1. Development of a hybrid mental speller combining EEG-based brain-computer interface and webcam-based eye-tracking.

    PubMed

    Lee, Jun-Hak; Lim, Jeong-Hwan; Hwang, Han-Jeong; Im, Chang-Hwan

    2013-01-01

    The main goal of this study was to develop a hybrid mental spelling system combining a steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) technology and a webcam-based eye-tracker, which utilizes information from the brain electrical activity and eye gaze direction at the same time. In the hybrid mental spelling system, a character decoded using SSVEP was not typed if the position of the selected character was not matched with the eye direction information ('left' or 'right') obtained from the eye-tracker. Thus, the users did not need to correct a misspelled character using a 'BACKSPACE' key. To verify the feasibility of the developed hybrid mental spelling system, we conducted online experiments with ten healthy participants. Each participant was asked to type 15 English words consisting of 68 characters. As a result, 16.6 typing errors could be prevented on average, demonstrating that the implemented hybrid mental spelling system could enhance the practicality of our mental spelling system.

  2. Oculomatic: High speed, reliable, and accurate open-source eye tracking for humans and non-human primates.

    PubMed

    Zimmermann, Jan; Vazquez, Yuriria; Glimcher, Paul W; Pesaran, Bijan; Louie, Kenway

    2016-09-01

    Video-based noninvasive eye trackers are an extremely useful tool for many areas of research. Many open-source eye trackers are available but current open-source systems are not designed to track eye movements with the temporal resolution required to investigate the mechanisms of oculomotor behavior. Commercial systems are available but employ closed source hardware and software and are relatively expensive, limiting wide-spread use. Here we present Oculomatic, an open-source software and modular hardware solution to eye tracking for use in humans and non-human primates. Oculomatic features high temporal resolution (up to 600Hz), real-time eye tracking with high spatial accuracy (<0.5°), and low system latency (∼1.8ms, 0.32ms STD) at a relatively low-cost. Oculomatic compares favorably to our existing scleral search-coil system while being fully non invasive. We propose that Oculomatic can support a wide range of research into the properties and neural mechanisms of oculomotor behavior. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Fusion of P300 and eye-tracker data for spelling using BCI2000

    NASA Astrophysics Data System (ADS)

    Kalika, Dmitry; Collins, Leslie; Caves, Kevin; Throckmorton, Chandra

    2017-10-01

    Objective. Various augmentative and alternative communication (AAC) devices have been developed in order to aid communication for individuals with communication disorders. Recently, there has been interest in combining EEG data and eye-gaze data with the goal of developing a hybrid (or ‘fused’) BCI (hBCI) AAC system. This work explores the effectiveness of a speller that fuses data from an eye-tracker and the P300 speller in order to create a hybrid P300 speller. Approach. This hybrid speller collects both eye-tracking and EEG data in parallel, and the user spells characters on the screen in the same way that they would if they were only using the P300 speller. Online and offline experiments were performed. The online experiments measured the performance of the speller for sixteen non-disabled participants, while the offline simulations were used to assess the robustness of the hybrid system. Main results. Online results showed that for fifteen non-disabled participants, using eye-gaze in a Bayesian framework with EEG data from the P300 speller improved accuracy (0.0163+/- 2.72 , 0.085+/- 0.111 , 0.080+/- 0.106 for estimated, medium and high variance configurations) and reduced the average number of flashes required to spell a character compared to the standard P300 speller that relies solely on EEG data (-53.27+/- 25.87 , -36.15+/- 19.3 , -18.85+/- 12.43 for estimated, medium and high variance configurations). Offline simulations indicate that the system provides more robust performance than a standalone eye gaze system. Significance. The results of this work on non-disabled participants shows the potential efficacy of hybrid P300 and eye-tracker speller. Further validation on the amyotrophic lateral sceloris population is needed to assess the benefit of this hybrid system.

  4. Benefits of Mobile Phone Technology for Personal Environmental Monitoring

    PubMed Central

    Carrasco-Turigas, Glòria; Seto, Edmund; Jerrett, Michael; Nieuwenhuijsen, Mark J

    2016-01-01

    Background Tracking individuals in environmental epidemiological studies using novel mobile phone technologies can provide valuable information on geolocation and physical activity, which will improve our understanding of environmental exposures. Objective The objective of this study was to assess the performance of one of the least expensive mobile phones on the market to track people's travel-activity pattern. Methods Adults living and working in Barcelona (72/162 bicycle commuters) carried simultaneously a mobile phone and a Global Positioning System (GPS) tracker and filled in a travel-activity diary (TAD) for 1 week (N=162). The CalFit app for mobile phones was used to log participants’ geographical location and physical activity. The geographical location data were assigned to different microenvironments (home, work or school, in transit, others) with a newly developed spatiotemporal map-matching algorithm. The tracking performance of the mobile phones was compared with that of the GPS trackers using chi-square test and Kruskal-Wallis rank sum test. The minute agreement across all microenvironments between the TAD and the algorithm was compared using the Gwet agreement coefficient (AC1). Results The mobile phone acquired locations for 905 (29.2%) more trips reported in travel diaries than the GPS tracker (P<.001) and had a median accuracy of 25 m. Subjects spent on average 57.9%, 19.9%, 9.0%, and 13.2% of time at home, work, in transit, and other places, respectively, according to the TAD and 57.5%, 18.8%, 11.6%, and 12.1%, respectively, according to the map-matching algorithm. The overall minute agreement between both methods was high (AC1 .811, 95% CI .810-.812). Conclusions The use of mobile phones running the CalFit app provides better information on which microenvironments people spend their time in than previous approaches based only on GPS trackers. The improvements of mobile phone technology in microenvironment determination are because the mobile phones are faster at identifying first locations and capable of getting location in challenging environments thanks to the combination of assisted-GPS technology and network positioning systems. Moreover, collecting location information from mobile phones, which are already carried by individuals, allows monitoring more people with a cheaper and less burdensome method than deploying GPS trackers. PMID:27833069

  5. Effects of mobile phone distraction on pedestrians' crossing behavior and visual attention allocation at a signalized intersection: An outdoor experimental study.

    PubMed

    Jiang, Kang; Ling, Feiyang; Feng, Zhongxiang; Ma, Changxi; Kumfer, Wesley; Shao, Chen; Wang, Kun

    2018-06-01

    With the rapid growth in mobile phone use worldwide, traffic safety experts have begun to consider the impact of mobile phone distractions on pedestrian crossing safety. This study sought to investigate how mobile phone distractions (music distraction, phone conversation distraction and text distraction) affect the behavior of pedestrians while they are crossing the street. An outdoor-environment experiment was conducted among 28 college student pedestrians. Two HD videos and an eye tracker were employed to record and analyze crossing behavior and visual attention allocation. The results of the research showed that the three mobile phone distractions cause different levels of impairment to pedestrians' crossing performance, with the greatest effect from text distraction, followed by phone conversation distraction and music distraction. Pedestrians distracted by music initiate crossing later, have increased pupil diameter, and reduce their scanning frequency, fixation points and fixation times toward traffic signal area priorities. In addition to the above effects, pedestrians distracted by phone conversation cross the street more slowly, direct fewer fixation points to the right traffic area, and spend less fixation time and lower average fixation duration on the left traffic area. Moreover, pedestrians distracted by texting look left and right less often and switch, distribute and maintain less visual attention on the traffic environment. These findings may inform researchers, policy makers, and pedestrians. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Developmental Milestones

    MedlinePlus

    ... 3 years 4 years 5 years Milestone Tracker App Milestones in Action: Photos & Videos 2 months 4 ... milestone checklists (PDF) Download the Milestone Tracker mobile app View the Milestones in Action photo and video ...

  7. A Critical Test of Temporal and Spatial Accuracy of the Tobii T60XL Eye Tracker

    ERIC Educational Resources Information Center

    Morgante, James D.; Zolfaghari, Rahman; Johnson, Scott P.

    2012-01-01

    Infant eye tracking is becoming increasingly popular for its presumed precision relative to traditional looking time paradigms and potential to yield new insights into developmental processes. However, there is strong reason to suspect that the temporal and spatial resolution of popular eye tracking systems is not entirely accurate, potentially…

  8. Gaze-Aware Streaming Solutions for the Next Generation of Mobile VR Experiences.

    PubMed

    Lungaro, Pietro; Sjoberg, Rickard; Valero, Alfredo Jose Fanghella; Mittal, Ashutosh; Tollmar, Konrad

    2018-04-01

    This paper presents a novel approach to content delivery for video streaming services. It exploits information from connected eye-trackers embedded in the next generation of VR Head Mounted Displays (HMDs). The proposed solution aims to deliver high visual quality, in real time, around the users' fixations points while lowering the quality everywhere else. The goal of the proposed approach is to substantially reduce the overall bandwidth requirements for supporting VR video experiences while delivering high levels of user perceived quality. The prerequisites to achieve these results are: (1) mechanisms that can cope with different degrees of latency in the system and (2) solutions that support fast adaptation of video quality in different parts of a frame, without requiring a large increase in bitrate. A novel codec configuration, capable of supporting near-instantaneous video quality adaptation in specific portions of a video frame, is presented. The proposed method exploits in-built properties of HEVC encoders and while it introduces a moderate amount of error, these errors are indetectable by users. Fast adaptation is the key to enable gaze-aware streaming and its reduction in bandwidth. A testbed implementing gaze-aware streaming, together with a prototype HMD with in-built eye tracker, is presented and was used for testing with real users. The studies quantified the bandwidth savings achievable by the proposed approach and characterize the relationships between Quality of Experience (QoE) and network latency. The results showed that up to 83% less bandwidth is required to deliver high QoE levels to the users, as compared to conventional solutions.

  9. Depression Screening Using Daily Mental-Health Ratings from a Smartphone Application for Breast Cancer Patients

    PubMed Central

    Kim, Junetae; Lim, Sanghee; Min, Yul Ha; Shin, Yong-Wook; Lee, Byungtae; Sohn, Guiyun; Jung, Kyung Hae; Lee, Jae-Ho; Son, Byung Ho; Ahn, Sei Hyun; Shin, Soo-Yong

    2016-01-01

    Background Mobile mental-health trackers are mobile phone apps that gather self-reported mental-health ratings from users. They have received great attention from clinicians as tools to screen for depression in individual patients. While several apps that ask simple questions using face emoticons have been developed, there has been no study examining the validity of their screening performance. Objective In this study, we (1) evaluate the potential of a mobile mental-health tracker that uses three daily mental-health ratings (sleep satisfaction, mood, and anxiety) as indicators for depression, (2) discuss three approaches to data processing (ratio, average, and frequency) for generating indicator variables, and (3) examine the impact of adherence on reporting using a mobile mental-health tracker and accuracy in depression screening. Methods We analyzed 5792 sets of daily mental-health ratings collected from 78 breast cancer patients over a 48-week period. Using the Patient Health Questionnaire-9 (PHQ-9) as the measure of true depression status, we conducted a random-effect logistic panel regression and receiver operating characteristic (ROC) analysis to evaluate the screening performance of the mobile mental-health tracker. In addition, we classified patients into two subgroups based on their adherence level (higher adherence and lower adherence) using a k-means clustering algorithm and compared the screening accuracy between the two groups. Results With the ratio approach, the area under the ROC curve (AUC) is 0.8012, indicating that the performance of depression screening using daily mental-health ratings gathered via mobile mental-health trackers is comparable to the results of PHQ-9 tests. Also, the AUC is significantly higher (P=.002) for the higher adherence group (AUC=0.8524) than for the lower adherence group (AUC=0.7234). This result shows that adherence to self-reporting is associated with a higher accuracy of depression screening. Conclusions Our results support the potential of a mobile mental-health tracker as a tool for screening for depression in practice. Also, this study provides clinicians with a guideline for generating indicator variables from daily mental-health ratings. Furthermore, our results provide empirical evidence for the critical role of adherence to self-reporting, which represents crucial information for both doctors and patients. PMID:27492880

  10. [Ablation on the undersurface of a LASIK flap. Instrument and method for continuous eye tracking].

    PubMed

    Taneri, S; Azar, D T

    2007-02-01

    The risk of iatrogenic keratectasia after laser in situ keratomileusis (LASIK) increases with thinner posterior stromal beds. Ablations on the undersurface of a LASIK flap could only be performed without the guidance of an eye tracker, which may lead to decentration. A new method for laser ablation with flying spot lasers on the undersurface of a LASIK flap was developed that enables the use of an active eye tracker by utilizing a novel instrument. The first clinical results are reported. Patients wishing an enhancement procedure were eligible for a modified repeat LASIK procedure if the flaps cut in the initial procedure were thick enough to perform the intended additional ablation on the undersurface leaving at least 90 microm of flap thickness behind. (1) The horizontal axis and the center of the entrance pupil were marked on the epithelial side of the flap using gentian violet dye. (2) The flap was reflected on a newly designed flap holder which had a donut-shaped black marking. (3) The eye tracker was centered on the mark visible in transparency on the flap. (4) Ablation with a flying spot Bausch & Lomb Technolas 217z laser was performed on the undersurface of the flap with a superior hinge taking into account that in astigmatic ablations the cylinder axis had to be mirrored according to the formula: axis on the undersurface=180 degrees -axis on the stromal bed. (5) The flap was repositioned. Detection of the marking on the modified flap holder and continuous tracking instead of the real pupil was possible in all of the 12 eyes treated with this technique. It may be necessary to cover the real pupil during ablation in order not to confuse the eye tracker. Ablation could be performed without decentration or loss of best spectacle-corrected visual acuity. Refractive results in minor corrections were good without nomogram adjustment. Using this novel flap holder with a marking that is tracked instead of the real pupil, centered ablations with a flying spot laser on the undersurface of a LASIK flap are feasible. Thus, the additional risk of iatrogenic keratectasia associated with stromal enhancement ablations is avoided.

  11. Eye tracking to evaluate evidence recognition in crime scene investigations.

    PubMed

    Watalingam, Renuka Devi; Richetelli, Nicole; Pelz, Jeff B; Speir, Jacqueline A

    2017-11-01

    Crime scene analysts are the core of criminal investigations; decisions made at the scene greatly affect the speed of analysis and the quality of conclusions, thereby directly impacting the successful resolution of a case. If an examiner fails to recognize the pertinence of an item on scene, the analyst's theory regarding the crime will be limited. Conversely, unselective evidence collection will most likely include irrelevant material, thus increasing a forensic laboratory's backlog and potentially sending the investigation into an unproductive and costly direction. Therefore, it is critical that analysts recognize and properly evaluate forensic evidence that can assess the relative support of differing hypotheses related to event reconstruction. With this in mind, the aim of this study was to determine if quantitative eye tracking data and qualitative reconstruction accuracy could be used to distinguish investigator expertise. In order to assess this, 32 participants were successfully recruited and categorized as experts or trained novices based on their practical experiences and educational backgrounds. Each volunteer then processed a mock crime scene while wearing a mobile eye tracker, wherein visual fixations, durations, search patterns, and reconstruction accuracy were evaluated. The eye tracking data (dwell time and task percentage on areas of interest or AOIs) were compared using Earth Mover's Distance (EMD) and the Needleman-Wunsch (N-W) algorithm, revealing significant group differences for both search duration (EMD), as well as search sequence (N-W). More specifically, experts exhibited greater dissimilarity in search duration, but greater similarity in search sequences than their novice counterparts. In addition to the quantitative visual assessment of examiner variability, each participant's reconstruction skill was assessed using a 22-point binary scoring system, in which significant group differences were detected as a function of total reconstruction accuracy. This result, coupled with the fact that the study failed to detect a significant difference between the groups when evaluating the total time needed to complete the investigation, indicates that experts are more efficient and effective. Finally, the results presented here provide a basis for continued research in the use of eye trackers to assess expertise in complex and distributed environments, including suggestions for future work, and cautions regarding the degree to which visual attention can infer cognitive understanding. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. An analysis of the suitability of a low-cost eye tracker for assessing the cognitive load of drivers.

    PubMed

    Čegovnik, Tomaž; Stojmenova, Kristina; Jakus, Grega; Sodnik, Jaka

    2018-04-01

    This paper presents a driving simulator study in which we investigated whether the Eye Tribe eye tracker (ET) is capable of assessing changes in the cognitive load of drivers through oculography and pupillometry. In the study, participants were asked to drive a simulated vehicle and simultaneously perform a set of secondary tasks with different cognitive complexity levels. We measured changes in eye properties, such as the pupil size, blink rate and fixation time. We also performed a measurement with a Detection Response Task (DRT) to validate the results and to prove a steady increase of cognitive load with increasing secondary task difficulty. The results showed that the ET precisely recognizes an increasing pupil diameter with increasing secondary task difficulty. In addition, the ET shows increasing blink rates, decreasing fixation time and narrowing of the attention field with increasing secondary task difficulty. The results were validated with the DRT method and the secondary task performance. We conclude that the Eye Tribe ET is a suitable device for assessing a driver's cognitive load. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Hybrid EEG--Eye Tracker: Automatic Identification and Removal of Eye Movement and Blink Artifacts from Electroencephalographic Signal.

    PubMed

    Mannan, Malik M Naeem; Kim, Shinjung; Jeong, Myung Yung; Kamran, M Ahmad

    2016-02-19

    Contamination of eye movement and blink artifacts in Electroencephalogram (EEG) recording makes the analysis of EEG data more difficult and could result in mislead findings. Efficient removal of these artifacts from EEG data is an essential step in improving classification accuracy to develop the brain-computer interface (BCI). In this paper, we proposed an automatic framework based on independent component analysis (ICA) and system identification to identify and remove ocular artifacts from EEG data by using hybrid EEG and eye tracker system. The performance of the proposed algorithm is illustrated using experimental and standard EEG datasets. The proposed algorithm not only removes the ocular artifacts from artifactual zone but also preserves the neuronal activity related EEG signals in non-artifactual zone. The comparison with the two state-of-the-art techniques namely ADJUST based ICA and REGICA reveals the significant improved performance of the proposed algorithm for removing eye movement and blink artifacts from EEG data. Additionally, results demonstrate that the proposed algorithm can achieve lower relative error and higher mutual information values between corrected EEG and artifact-free EEG data.

  14. Experimental study of visual accommodation

    NASA Technical Reports Server (NTRS)

    Cornsweet, T. N.; Crane, H. D.

    1972-01-01

    A summary report of a research effort related to the human visual accommodation system is presented. A theoretical study of the accommodation system was made. Subsequent effort was aimed at the development of specialized instrumentation for experiments designed to lead to understanding the nature of the control system in human accommodation. The necessary instrumentation consisted primarily of: (1) an automatic optometer to measure the state of eye focus, (2) a focus stimulator device to control the apparent optical distance to any target, and (3) a two-dimensional eye tracker. The concepts and designs of the first two instruments have been published in the open literature, but this report contains the first detailed treatment of the Purkinje eye tracker developed under this program. The report also discusses an accommodation lag model to explain the ability of the eye to apparently know the polarity of focus error even though the blur on the retina is to a first-approximation an even function. The interaction of the accommodation and eye movement systems is also discussed, as is the ability to train the visual accommodation system to a surprisingly responsive condition in only a few hours of training.

  15. NIR tracking assists sports medicine in junior basketball training

    NASA Astrophysics Data System (ADS)

    Paeglis, Roberts; Bluss, Kristaps; Rudzitis, Andris; Spunde, Andris; Brice, Tamara; Nitiss, Edgars

    2011-07-01

    We recorded eye movements of eight elite junior basketball players. We hypothesized that a more stable gaze is correlated to a better shot rate. Upon preliminary testing we invited male juniors whose eyes could be reliably tracked in a game situation. To these ends, we used a head-mounted video-based eye tracker. The participants had no record of ocular or other health issues. No significant differences were found between shots made with and without the tracker cap, Paired samples t-test yielded p= .130 for the far and p=..900 > .050 for the middle range shots. The players made 40 shots from common far and middle range locations, 5 and 4 meters respectively for aged 14 years As expected, a statistical correlation was found between gaze fixation (in milliseconds) for the far and middle range shot rates, r=.782, p=.03. Notably, juniors who fixated longer before a shot had a more stable fixation or a lower gaze dispersion (in tracker's screen pixels), r=-.786, p=.02. This finding was augmented by the observation that the gaze dispersion while aiming at the basket was less (i.e., gaze more stable) in those who were more likely to score. We derived a regression equation linking fixation duration to shot success. We advocate infra-red eye tracking as a means to monitor player selection and training success.

  16. Humor in the eye tracker: attention capture and distraction from context cues.

    PubMed

    Strick, Madelijn; Holland, Rob W; Van Baaren, Rick; Van Knippenberg, Ad

    2010-01-01

    The humor effect refers to a robust finding in memory research that humorous information is easily recalled, at the expense of recall of nonhumorous information that was encoded in close temporal proximity. Previous research suggests that memory retrieval processes underlie this effect. That is, free recall is biased toward humorous information, which interferes with the retrieval of nonhumorous information. The present research tested an additional explanation that has not been specifically addressed before: Humor receives enhanced attention during information encoding, which decreases attention for context information. Participants observed humorous, nonhumorous positive, and nonhumorous neutral texts paired with novel consumer brands, while their eye movements were recorded using eye-tracker technology. The results confirmed that humor receives prolonged attention relative to both positive and neutral nonhumorous information. This enhanced attention correlated with impaired brand recognition.

  17. Benefits of Mobile Phone Technology for Personal Environmental Monitoring.

    PubMed

    Donaire-Gonzalez, David; Valentín, Antònia; de Nazelle, Audrey; Ambros, Albert; Carrasco-Turigas, Glòria; Seto, Edmund; Jerrett, Michael; Nieuwenhuijsen, Mark J

    2016-11-10

    Tracking individuals in environmental epidemiological studies using novel mobile phone technologies can provide valuable information on geolocation and physical activity, which will improve our understanding of environmental exposures. The objective of this study was to assess the performance of one of the least expensive mobile phones on the market to track people's travel-activity pattern. Adults living and working in Barcelona (72/162 bicycle commuters) carried simultaneously a mobile phone and a Global Positioning System (GPS) tracker and filled in a travel-activity diary (TAD) for 1 week (N=162). The CalFit app for mobile phones was used to log participants' geographical location and physical activity. The geographical location data were assigned to different microenvironments (home, work or school, in transit, others) with a newly developed spatiotemporal map-matching algorithm. The tracking performance of the mobile phones was compared with that of the GPS trackers using chi-square test and Kruskal-Wallis rank sum test. The minute agreement across all microenvironments between the TAD and the algorithm was compared using the Gwet agreement coefficient (AC1). The mobile phone acquired locations for 905 (29.2%) more trips reported in travel diaries than the GPS tracker (P<.001) and had a median accuracy of 25 m. Subjects spent on average 57.9%, 19.9%, 9.0%, and 13.2% of time at home, work, in transit, and other places, respectively, according to the TAD and 57.5%, 18.8%, 11.6%, and 12.1%, respectively, according to the map-matching algorithm. The overall minute agreement between both methods was high (AC1 .811, 95% CI .810-.812). The use of mobile phones running the CalFit app provides better information on which microenvironments people spend their time in than previous approaches based only on GPS trackers. The improvements of mobile phone technology in microenvironment determination are because the mobile phones are faster at identifying first locations and capable of getting location in challenging environments thanks to the combination of assisted-GPS technology and network positioning systems. Moreover, collecting location information from mobile phones, which are already carried by individuals, allows monitoring more people with a cheaper and less burdensome method than deploying GPS trackers. ©David Donaire-Gonzalez, Antònia Valentín, Audrey de Nazelle, Albert Ambros, Glòria Carrasco-Turigas, Edmund Seto, Michael Jerrett, Mark J Nieuwenhuijsen. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 10.11.2016.

  18. An investigation of pupil-based cognitive load measurement with low cost infrared webcam under light reflex interference.

    PubMed

    Chen, Siyuan; Epps, Julien; Chen, Fang

    2013-01-01

    Using the task-evoked pupillary response (TEPR) to index cognitive load can contribute significantly to the assessment of memory function and cognitive skills in patients. However, the measurement of pupillary response is currently limited to a well-controlled lab environment due to light reflex and also relies heavily on expensive video-based eye trackers. Furthermore, commercial eye trackers are usually dedicated to gaze direction measurement, and their calibration procedure and computing resource are largely redundant for pupil-based cognitive load measurement (PCLM). In this study, we investigate the validity of cognitive load measurement with (i) pupil light reflex in a less controlled luminance background; (ii) a low-cost infrared (IR) webcam for the TEPR in a controlled luminance background. ANOVA results show that with an appropriate baseline selection and subtraction, the light reflex is significantly reduced, suggesting the possibility of less constrained practical applications of PCLM. Compared with the TEPR from a commercial remote eye tracker, a low-cost IR webcam achieved a similar TEPR pattern and no significant difference was found between the two devices in terms of cognitive load measurement across five induced load levels.

  19. Bayesian microsaccade detection

    PubMed Central

    Mihali, Andra; van Opheusden, Bas; Ma, Wei Ji

    2017-01-01

    Microsaccades are high-velocity fixational eye movements, with special roles in perception and cognition. The default microsaccade detection method is to determine when the smoothed eye velocity exceeds a threshold. We have developed a new method, Bayesian microsaccade detection (BMD), which performs inference based on a simple statistical model of eye positions. In this model, a hidden state variable changes between drift and microsaccade states at random times. The eye position is a biased random walk with different velocity distributions for each state. BMD generates samples from the posterior probability distribution over the eye state time series given the eye position time series. Applied to simulated data, BMD recovers the “true” microsaccades with fewer errors than alternative algorithms, especially at high noise. Applied to EyeLink eye tracker data, BMD detects almost all the microsaccades detected by the default method, but also apparent microsaccades embedded in high noise—although these can also be interpreted as false positives. Next we apply the algorithms to data collected with a Dual Purkinje Image eye tracker, whose higher precision justifies defining the inferred microsaccades as ground truth. When we add artificial measurement noise, the inferences of all algorithms degrade; however, at noise levels comparable to EyeLink data, BMD recovers the “true” microsaccades with 54% fewer errors than the default algorithm. Though unsuitable for online detection, BMD has other advantages: It returns probabilities rather than binary judgments, and it can be straightforwardly adapted as the generative model is refined. We make our algorithm available as a software package. PMID:28114483

  20. Ecological Validity in Eye-Tracking: An Empirical Study

    ERIC Educational Resources Information Center

    Spinner, Patti; Gass, Susan M.; Behney, Jennifer

    2013-01-01

    Eye-trackers are becoming increasingly widespread as a tool to investigate second language (L2) acquisition. Unfortunately, clear standards for methodology--including font size, font type, and placement of interest areas--are not yet available. Although many researchers stress the need for ecological validity--that is, the simulation of natural…

  1. Hybrid EEG—Eye Tracker: Automatic Identification and Removal of Eye Movement and Blink Artifacts from Electroencephalographic Signal

    PubMed Central

    Mannan, Malik M. Naeem; Kim, Shinjung; Jeong, Myung Yung; Kamran, M. Ahmad

    2016-01-01

    Contamination of eye movement and blink artifacts in Electroencephalogram (EEG) recording makes the analysis of EEG data more difficult and could result in mislead findings. Efficient removal of these artifacts from EEG data is an essential step in improving classification accuracy to develop the brain-computer interface (BCI). In this paper, we proposed an automatic framework based on independent component analysis (ICA) and system identification to identify and remove ocular artifacts from EEG data by using hybrid EEG and eye tracker system. The performance of the proposed algorithm is illustrated using experimental and standard EEG datasets. The proposed algorithm not only removes the ocular artifacts from artifactual zone but also preserves the neuronal activity related EEG signals in non-artifactual zone. The comparison with the two state-of-the-art techniques namely ADJUST based ICA and REGICA reveals the significant improved performance of the proposed algorithm for removing eye movement and blink artifacts from EEG data. Additionally, results demonstrate that the proposed algorithm can achieve lower relative error and higher mutual information values between corrected EEG and artifact-free EEG data. PMID:26907276

  2. Eyelid contour detection and tracking for startle research related eye-blink measurements from high-speed video records.

    PubMed

    Bernard, Florian; Deuter, Christian Eric; Gemmar, Peter; Schachinger, Hartmut

    2013-10-01

    Using the positions of the eyelids is an effective and contact-free way for the measurement of startle induced eye-blinks, which plays an important role in human psychophysiological research. To the best of our knowledge, no methods for an efficient detection and tracking of the exact eyelid contours in image sequences captured at high-speed exist that are conveniently usable by psychophysiological researchers. In this publication a semi-automatic model-based eyelid contour detection and tracking algorithm for the analysis of high-speed video recordings from an eye tracker is presented. As a large number of images have been acquired prior to method development it was important that our technique is able to deal with images that are recorded without any special parametrisation of the eye tracker. The method entails pupil detection, specular reflection removal and makes use of dynamic model adaption. In a proof-of-concept study we could achieve a correct detection rate of 90.6%. With this approach, we provide a feasible method to accurately assess eye-blinks from high-speed video recordings. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. [Comparison study on subjective and objective measurements of the accommodative convergence to accommodation ratio].

    PubMed

    Xu, Jing-jing; Xu, Dan; Huang, Tao; Jiang, Jian; Lü, Fan

    2012-05-01

    To detect the accommodative convergence to accommodation (AC/A) ratios measured respectively by objective and subjective methods. The differences and its relative factors were explored. Forty young volunteers were measured by eye tracker to get the amount of convergence when fixating at the target at 100 cm, 50 cm, 33 cm and 25 cm and were measured by infrared auto-refractor to get corresponding accommodative responses. AC/A ratio based on these two measurements were compared with the calculated and the gradient AC/A ratio from Von Graefe tests. Mean value of stimulated AC/A ratio measured by eye tracker was higher than the calculated and gradient AC/A ratio by Von Graefe method (P = 0.003, 0.001). There are statistic correlation (r = 0.871, P = 0.000) and difference (P = 0.000) between stimulated AC/A ratio and response AC/A ratios both measured by eye tracker, and the difference trends to be greater with the higher AC/A ratio. The objective AC/A ratio is usually higher than the clinical subjective measurement because of more proximal effect. The response AC/A ratio measured objectively may reveal realistically the mutual effect and relationship between accommodation and convergence and it seems to be more credible to be the monitor parameter on progression of myopia in clinics.

  4. Integrating Eye Trackers with Handwriting Tablets to Discover Difficulties of Solving Geometry Problems

    ERIC Educational Resources Information Center

    Lin, John J. H.; Lin, Sunny S. J.

    2018-01-01

    To deepen our understanding of those aspects of problems that cause the most difficulty for solvers, this study integrated eye-tracking with handwriting devices to investigate problem solvers' online processes while solving geometry problems. We are interested in whether the difference between successful and unsuccessful solvers can be identified…

  5. Identifying and assessing strategies for evaluating the impact of mobile eye health units on health outcomes.

    PubMed

    Fu, Shiwan; Turner, Angus; Tan, Irene; Muir, Josephine

    2017-12-01

    To identify and assess strategies for evaluating the impact of mobile eye health units on health outcomes. Systematic literature review. Worldwide. Peer-reviewed journal articles that included the use of a mobile eye health unit. Journal articles were included if outcome measures reflected an assessment of the impact of a mobile eye health unit on health outcomes. Six studies were identified with mobile services offering diabetic retinopathy screening (three studies), optometric services (two studies) and orthoptic services (one study). This review identified and assessed strategies in existing literature used to evaluate the impact of mobile eye health units on health outcomes. Studies included in this review used patient outcomes (i.e. disease detection, vision impairment, treatment compliance) and/or service delivery outcomes (i.e. cost per attendance, hospital transport use, inappropriate referrals, time from diabetic retinopathy photography to treatment) to evaluate the impact of mobile eye health units. Limitations include difficulty proving causation of specific outcome measures and the overall shortage of impact evaluation studies. Variation in geographical location, service population and nature of eye care providers limits broad application. © 2017 National Rural Health Alliance Inc.

  6. Modelling and precision of the localization of the robotic mobile platforms for constructions with laser tracker and SmartTrack sensor

    NASA Astrophysics Data System (ADS)

    Dima, M.; Francu, C.

    2016-08-01

    This paper presents a way to expand the field of use of the laser tracker and SmartTrack sensor localization device used in lately for the localisation of the end effector of the industrial robots to the localization of the mobile construction robots. The research paper presents the equipment along with its characteristics, determines the relationships for the localization coordinates by comparison to the forward kinematics of the industrial robot's spherical arm (positioning mechanism in spherical coordinates) and the orientation mechanism with three revolute axes. In the end of the paper the accuracy of the mobile robot's localization is analysed.

  7. Eye movement perimetry in glaucoma.

    PubMed

    Trope, G E; Eizenman, M; Coyle, E

    1989-08-01

    Present-day computerized perimetry is often inaccurate and unreliable owing to the need to maintain central fixation over long periods while repressing the normal response to presentation of peripheral stimuli. We tested a new method of perimetry that does not require prolonged central fixation. During this test eye movements were encouraged on presentation of a peripheral target. Twenty-three eyes were studied with an Octopus perimeter, with a technician monitoring eye movements. The sensitivity was 100% and the specificity 23%. The low specificity was due to the technician's inability to accurately monitor small eye movements in the central 6 degrees field. If small eye movements are monitored accurately with an eye tracker, eye movement perimetry could become an alternative method to standard perimetry.

  8. Looking Forward: Comment on Morgante, Zolfaghari, and Johnson

    ERIC Educational Resources Information Center

    Creel, Sarah C.

    2012-01-01

    Morgante et al. (in press) find inconsistencies in the time reporting of a Tobii T60XL eye tracker. Their study raises important questions about the use of the Tobii T-series in particular, and various software and hardware in general, in different infant eye tracking paradigms. It leaves open the question of the source of the inconsistencies.…

  9. Are fixations in static natural scenes a useful predictor of attention in the real world?

    PubMed

    Foulsham, Tom; Kingstone, Alan

    2017-06-01

    Research investigating scene perception normally involves laboratory experiments using static images. Much has been learned about how observers look at pictures of the real world and the attentional mechanisms underlying this behaviour. However, the use of static, isolated pictures as a proxy for studying everyday attention in real environments has led to the criticism that such experiments are artificial. We report a new study that tests the extent to which the real world can be reduced to simpler laboratory stimuli. We recorded the gaze of participants walking on a university campus with a mobile eye tracker, and then showed static frames from this walk to new participants, in either a random or sequential order. The aim was to compare the gaze of participants walking in the real environment with fixations on pictures of the same scene. The data show that picture order affects interobserver fixation consistency and changes looking patterns. Critically, while fixations on the static images overlapped significantly with the actual real-world eye movements, they did so no more than a model that assumed a general bias to the centre. Remarkably, a model that simply takes into account where the eyes are normally positioned in the head-independent of what is actually in the scene-does far better than any other model. These data reveal that viewing patterns to static scenes are a relatively poor proxy for predicting real world eye movement behaviour, while raising intriguing possibilities for how to best measure attention in everyday life. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  10. Ablation centration after active eye tracker-assisted LASIK and comparison of flying-spot and broad-beam laser.

    PubMed

    Lin, Jane-Ming; Chen, Wen-Lu; Chiang, Chun-Chi; Tsai, Yi-Yu

    2008-04-01

    To evaluate ablation centration of flying-spot LASIK, investigate the effect of patient- and surgeon-related factors on centration, and compare flying-spot and broad-beam laser results. This retrospective study comprised 173 eyes of 94 patients who underwent LASIK with the Alcon LADARVision4000 with an active eye-tracking system. The effective tracking rate of the system is 100 Hz. The amount of decentration was analyzed by corneal topography. Patient- (low, high, and extreme myopia; effect of learning) and surgeon-related (learning curve) factors influencing centration were identified. Centration was compared to the SCHWIND Multiscan broad-beam laser with a 50-Hz tracker from a previous study. Mean decentration was 0.36+/-0.18 mm (range: 0 to 0.9 mm). Centration did not differ in low, high, and extreme myopia or in patients' first and second eyes. There were no significant differences in centration between the first 50 LASIK procedures and the last 50 procedures. Comparing flying-spot and broad-beam laser results, there were no differences in centration in low myopia. However, the LADARVision4000 yielded better centration results in high and extreme myopia. The Alcon LADARVision4000 active eye tracking system provides good centration for all levels of myopic correction and better centration than the Schwind broad-beam Multiscan in eyes with high and extreme myopia.

  11. Trends in communicative access solutions for children with cerebral palsy.

    PubMed

    Myrden, Andrew; Schudlo, Larissa; Weyand, Sabine; Zeyl, Timothy; Chau, Tom

    2014-08-01

    Access solutions may facilitate communication in children with limited functional speech and motor control. This study reviews current trends in access solution development for children with cerebral palsy, with particular emphasis on the access technology that harnesses a control signal from the user (eg, movement or physiological change) and the output device (eg, augmentative and alternative communication system) whose behavior is modulated by the user's control signal. Access technologies have advanced from simple mechanical switches to machine vision (eg, eye-gaze trackers), inertial sensing, and emerging physiological interfaces that require minimal physical effort. Similarly, output devices have evolved from bulky, dedicated hardware with limited configurability, to platform-agnostic, highly personalized mobile applications. Emerging case studies encourage the consideration of access technology for all nonverbal children with cerebral palsy with at least nascent contingency awareness. However, establishing robust evidence of the effectiveness of the aforementioned advances will require more expansive studies. © The Author(s) 2014.

  12. Adaptive optics optical coherence tomography with dynamic retinal tracking

    PubMed Central

    Kocaoglu, Omer P.; Ferguson, R. Daniel; Jonnal, Ravi S.; Liu, Zhuolin; Wang, Qiang; Hammer, Daniel X.; Miller, Donald T.

    2014-01-01

    Adaptive optics optical coherence tomography (AO-OCT) is a highly sensitive and noninvasive method for three dimensional imaging of the microscopic retina. Like all in vivo retinal imaging techniques, however, it suffers the effects of involuntary eye movements that occur even under normal fixation. In this study we investigated dynamic retinal tracking to measure and correct eye motion at KHz rates for AO-OCT imaging. A customized retina tracking module was integrated into the sample arm of the 2nd-generation Indiana AO-OCT system and images were acquired on three subjects. Analyses were developed based on temporal amplitude and spatial power spectra in conjunction with strip-wise registration to independently measure AO-OCT tracking performance. After optimization of the tracker parameters, the system was found to correct eye movements up to 100 Hz and reduce residual motion to 10 µm root mean square. Between session precision was 33 µm. Performance was limited by tracker-generated noise at high temporal frequencies. PMID:25071963

  13. Experimental support that ocular tremor in Parkinson's disease does not originate from head movement.

    PubMed

    Gitchel, George T; Wetzel, Paul A; Qutubuddin, Abu; Baron, Mark S

    2014-07-01

    Our recent report of ocular tremor in Parkinson's disease (PD) has raised considerable controversy as to the origin of the tremor. Using an infrared based eye tracker and a magnetic head tracker, we reported that ocular tremor was recordable in PD subjects with no apparent head tremor. However, other investigators suggest that the ocular tremor may represent either transmitted appendicular tremor or subclinical head tremor inducing the vestibulo-ocular reflex (VOR). The present study aimed to further investigate the origin of ocular tremor in PD. Eye movements were recorded in 8 PD subjects both head free, and with full head restraint by means of a head holding device and a dental impression bite plate. Head movements were recorded independently using both a high sensitivity tri-axial accelerometer and a magnetic tracking system, each synchronized to the eye tracker. Ocular tremor was observed in all 8 PD subjects and was not influenced by head free and head fixed conditions. Both magnetic tracking and accelerometer recordings supported that the ocular tremor was fully independent of head position. The present study findings support our initial findings that ocular tremor is a fundamental feature of PD unrelated to head movements. Although the utility of ocular tremor for diagnostic purposes requires validation, current findings in large cohorts of PD subjects suggest its potential as a reliable clinical biomarker. Published by Elsevier Ltd.

  14. Utility of the T2 Mood Tracker mobile application among army warrior transition unit service members.

    PubMed

    Bush, Nigel E; Ouellette, Gary; Kinn, Julie

    2014-12-01

    Many military personnel returning from deployment experience increases in psychological symptoms, including post-traumatic stress disorder (PTSD), depression, and mood changes. Patient health diaries are commonly used for self-reporting over time away from the clinic. "T2 Mood Tracker" is an application ("app") for smartphones and other mobile devices that enables users to rate their moods, to self-monitor across time, and to report their emotional experiences to health providers. We designed T2 Mood Tracker to track symptoms associated with deployment-related behavioral health issues, including PTSD, Head Injury, Stress, Depression, Anxiety, and General Well-Being. We field-tested T2 Mood Tracker with a small sample of redeployed soldiers under treatment for behavioral health issues at a Warrior Transition Unit. Participants used the app an average of 10 different days over the 2- to 3-week test period. Consensus was that T2 Mood Tracker was easy to use, useful and beneficial. The majority said they would use the app in the future, would recommend it to other service members, and would use the app to share their mood information with a provider. Warrior Transition Unit providers were enthusiastic about the potential of T2 Mood Tracker as a tool for use with their patients. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.

  15. SacLab: A toolbox for saccade analysis to increase usability of eye tracking systems in clinical ophthalmology practice.

    PubMed

    Cercenelli, Laura; Tiberi, Guido; Corazza, Ivan; Giannaccare, Giuseppe; Fresina, Michela; Marcelli, Emanuela

    2017-01-01

    Many open source software packages have been recently developed to expand the usability of eye tracking systems to study oculomotor behavior, but none of these is specifically designed to encompass all the main functions required for creating eye tracking tests and for providing the automatic analysis of saccadic eye movements. The aim of this study is to introduce SacLab, an intuitive, freely-available MATLAB toolbox based on Graphical User Interfaces (GUIs) that we have developed to increase the usability of the ViewPoint EyeTracker (Arrington Research, Scottsdale, AZ, USA) in clinical ophthalmology practice. SacLab consists of four processing modules that enable the user to easily create visual stimuli tests (Test Designer), record saccadic eye movements (Data Recorder), analyze the recorded data to automatically extract saccadic parameters of clinical interest (Data Analyzer) and provide an aggregate analysis from multiple eye movements recordings (Saccade Analyzer), without requiring any programming effort by the user. A demo application of SacLab to carry out eye tracking tests for the analysis of horizontal saccades was reported. We tested the usability of SacLab toolbox with three ophthalmologists who had no programming experience; the ophthalmologists were briefly trained in the use of SacLab GUIs and were asked to perform the demo application. The toolbox gained an enthusiastic feedback from all the clinicians in terms of intuitiveness, ease of use and flexibility. Test creation and data processing were accomplished in 52±21s and 46±19s, respectively, using the SacLab GUIs. SacLab may represent a useful tool to ease the application of the ViewPoint EyeTracker system in clinical routine in ophthalmology. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Using an eye tracker during medication administration to identify gaps in nursing students' contextual knowledge: an observational study.

    PubMed

    Amster, Brian; Marquard, Jenna; Henneman, Elizabeth; Fisher, Donald

    2015-01-01

    In this clinical simulation study using an eye-tracking device, 40% of senior nursing students administered a contraindicated medication to a patient. Our findings suggest that the participants who did not identify the error did not know that amoxicillin is a type of penicillin. Eye-tracking devices may be valuable for determining whether nursing students are making rule- or knowledge-based errors, a distinction not easily captured via observations and interviews.

  17. Television Subtitles and Literacy: Where Do We Go from Here?

    ERIC Educational Resources Information Center

    Hefer, Esté

    2013-01-01

    Subtitling is a valuable tool for improving literacy and aiding language learning, but what happens when people are unable to read the subtitles? In a recent study on the reading of second language subtitles, participants were shown a subtitled short film while their eye movements were recorded by an SMI iViewX Hi-Speed eye tracker. It was found…

  18. The Learning Benefits of Using Eye Trackers to Enhance the Geospatial Abilities of Elementary School Students

    ERIC Educational Resources Information Center

    Wang, Hsiao-shen; Chen, Yi-Ting; Lin, Chih-Hung

    2014-01-01

    In this study, we examined the spatial abilities of students using eye-movement tracking devices to identify and analyze their characteristics. For this research, 12 students aged 11-12 years participated as novices and 4 mathematics students participated as experts. A comparison of the visual-spatial abilities of each group showed key factors of…

  19. Application of video-based technology for the simultaneous measurement of accommodation and vergence.

    PubMed

    Suryakumar, Rajaraman; Meyers, Jason P; Irving, Elizabeth L; Bobier, William R

    2007-01-01

    Accommodation and vergence are two ocular motor systems that interact during binocular vision. Independent measurement of the response dynamics of each system has been achieved by the application of optometers and eye trackers. However, relatively few devices, typically earlier model optometers, allow the simultaneous assessment of accommodation and vergence. In this study we describe the development and application of a custom designed high-speed digital photorefractor that allows for rapid measures of accommodation (up to 75Hz). In addition the photorefractor was also synchronized with a video-based stereo eye tracker to allow a simultaneous measurement of accommodation and vergence. Analysis of accommodation and vergence could then be conducted offline. The new instrumentation is suitable for investigation of young children and could be potentially used for clinical populations.

  20. How Do We See Art: An Eye-Tracker Study

    PubMed Central

    Quiroga, Rodrigo Quian; Pedreira, Carlos

    2011-01-01

    We describe the pattern of fixations of subjects looking at figurative and abstract paintings from different artists (Molina, Mondrian, Rembrandt, della Francesca) and at modified versions in which different aspects of these art pieces were altered with simple digital manipulations. We show that the fixations of the subjects followed some general common principles (e.g., being attracted to saliency regions) but with a large variability for the figurative paintings, according to the subject’s personal appreciation and knowledge. In particular, we found different gazing patterns depending on whether the subject saw the original or the modified version of the painting first. We conclude that the study of gazing patterns obtained by using the eye-tracker technology gives a useful approach to quantify how subjects observe art. PMID:21941476

  1. Is it reliable to assess visual attention of drivers affected by Parkinson's disease from the backseat?—a simulator study

    PubMed Central

    Lee, Hoe C.; Yanting Chee, Derserri; Selander, Helena; Falkmer, Torbjorn

    2012-01-01

    Background Current methods of determining licence retainment or cancellation is through on-road driving tests. Previous research has shown that occupational therapists frequently assess drivers’ visual attention while sitting in the back seat on the opposite side of the driver. Since the eyes of the driver are not always visible, assessment by eye contact becomes problematic. Such procedural drawbacks may challenge validity and reliability of the visual attention assessments. In terms of correctly classified attention, the aim of the study was to establish the accuracy and the inter-rater reliability of driving assessments of visual attention from the back seat. Furthermore, by establishing eye contact between the assessor and the driver through an additional mirror on the wind screen, the present study aimed to establish how much such an intervention would enhance the accuracy of the visual attention assessment. Methods Two drivers with Parkinson's disease (PD) and six control drivers drove a fixed route in a driving simulator while wearing a head mounted eye tracker. The eye tracker data showed where the foveal visual attention actually was directed. These data were time stamped and compared with the simultaneous manual scoring of the visual attention of the drivers. In four of the drivers, one with Parkinson's disease, a mirror on the windscreen was set up to arrange for eye contact between the driver and the assessor. Inter-rater reliability was performed with one of the Parkinson drivers driving, but without the mirror. Results Without mirror, the overall accuracy was 56% when assessing the three control drivers and with mirror 83%. However, for the PD driver without mirror the accuracy was 94%, whereas for the PD driver with a mirror the accuracy was 90%. With respect to the inter-rater reliability, a 73% agreement was found. Conclusion If the final outcome of a driving assessment is dependent on the subcategory of a protocol assessing visual attention, we suggest the use of an additional mirror to establish eye contact between the assessor and the driver. The clinicians’ observations on-road should not be a standalone assessment in driving assessments. Instead, eye trackers should be employed for further analyses and correlation in cases where there is doubt about a driver's attention. PMID:22461850

  2. Kappa and Hirschberg ratio measured with an automated video gaze tracker.

    PubMed

    Schaeffel, Frank

    2002-05-01

    To develop a fast automated procedure to measure kappa and the Hirschberg ratio for immediate use in a video gaze tracker. Using the hardware platform of the PowerRefractor and a 200 mm lens, the pupil was imaged with a resolution of 57 pixels/mm, at a camera distance of 90 cm. Both the positions of the first Purkinje image and the edges of the pupil were located at 25 Hz sampling rate with subpixel resolution using video image processing software developed under Borland C++. Subjects fixated on a red spot on the left side of the monitor. If their fixation was stable (standard deviation <0.2 degrees in 25 subsequent measurements evaluated in 1 s), the fixation spot appeared automatically on the right side, and the procedure was repeated. Data on the angular position of the optical axis for both targets were stored and provided kappa and the Hirschberg ratio with a standard deviation of about 0.2 degrees or better. This enabled the system to track fixation with a resolution of about 0.2 degrees. (1) Kappa was +3.91+/-2.73 degrees (right eyes), -3.93+/-2.68 degrees (left eyes, mean +/- SD from 24 young adults). Kappa was highly correlated in both eyes (r = 0.8996), but there were significant asymmetries between both eyes in three subjects (delta up to 3 degrees). (2) The Hirschberg ratios were 12.93+/-1.23 degrees/mm = 22.56 delta/mm (right eyes) and 12.82+/-1.49 degrees/mm = 22.38 delta/mm (left eyes). They were also highly correlated in both eyes (r = 0.931). (3) Neither kappa nor the Hirschberg ratios were correlated to refractive errors (range +0.50 to -7.75 D, mean -1.73+/-2.29 D [spherical equivalents]). (1) The video gaze tracker measured fixation with an angular resolution high enough to display the eye position during reading of individual words on the computer screen. (2) The applicable Hirschberg ratio changed with the power of the spectacles of the subjects by about 3% per diopter. (3) In some subjects, there were significant differences in the geometry of both eyeballs, which may be important in the analysis of strabismus. (4) Consistent with the assumption of retinal stretching, the linear distance of the fovea from the optical axis appeared to increase in myopia.

  3. Remote vs. head-mounted eye-tracking: a comparison using radiologists reading mammograms

    NASA Astrophysics Data System (ADS)

    Mello-Thoms, Claudia; Gur, David

    2007-03-01

    Eye position monitoring has been used for decades in Radiology in order to determine how radiologists interpret medical images. Using these devices several discoveries about the perception/decision making process have been made, such as the importance of comparisons of perceived abnormalities with selected areas of the background, the likelihood that a true lesion will attract visual attention early in the reading process, and the finding that most misses attract prolonged visual dwell, often comparable to dwell in the location of reported lesions. However, eye position tracking is a cumbersome process, which often requires the observer to wear a helmet gear which contains the eye tracker per se and a magnetic head tracker, which allows for the computation of head position. Observers tend to complain of fatigue after wearing the gear for a prolonged time. Recently, with the advances made to remote eye-tracking, the use of head-mounted systems seemed destined to become a thing of the past. In this study we evaluated a remote eye tracking system, and compared it to a head-mounted system, as radiologists read a case set of one-view mammograms on a high-resolution display. We compared visual search parameters between the two systems, such as time to hit the location of the lesion for the first time, amount of dwell time in the location of the lesion, total time analyzing the image, etc. We also evaluated the observers' impressions of both systems, and what their perceptions were of the restrictions of each system.

  4. Association between vestibulo-ocular reflex suppression, balance, gait, and fall risk in ageing and neurodegenerative disease: protocol of a one-year prospective follow-up study.

    PubMed

    Srulijes, Karin; Mack, David J; Klenk, Jochen; Schwickert, Lars; Ihlen, Espen A F; Schwenk, Michael; Lindemann, Ulrich; Meyer, Miriam; Srijana, K C; Hobert, Markus A; Brockmann, Kathrin; Wurster, Isabel; Pomper, Jörn K; Synofzik, Matthis; Schneider, Erich; Ilg, Uwe; Berg, Daniela; Maetzler, Walter; Becker, Clemens

    2015-10-09

    Falls frequency increases with age and particularly in neurogeriatric cohorts. The interplay between eye movements and locomotion may contribute substantially to the occurrence of falls, but is hardly investigated. This paper provides an overview of current approaches to simultaneously measure eye and body movements, particularly for analyzing the association of vestibulo-ocular reflex (VOR) suppression, postural deficits and falls in neurogeriatric risk cohorts. Moreover, VOR suppression is measured during head-fixed target presentation and during gaze shifting while postural control is challenged. Using these approaches, we aim at identifying quantitative parameters of eye-head-coordination during postural balance and gait, as indicators of fall risk. Patients with Progressive Supranuclear Palsy (PSP) or Parkinson's disease (PD), age- and sex-matched healthy older adults, and a cohort of young healthy adults will be recruited. Baseline assessment will include a detailed clinical assessment, covering medical history, neurological examination, disease specific clinical rating scales, falls-related self-efficacy, activities of daily living, neuro-psychological screening, assessment of mobility function and a questionnaire for retrospective falls. Moreover, participants will simultaneously perform eye and head movements (fixating a head-fixed target vs. shifting gaze to light emitting diodes in order to quantify vestibulo-ocular reflex suppression ability) under different conditions (sitting, standing, or walking). An eye/head tracker synchronized with a 3-D motion analysis system will be used to quantify parameters related to eye-head-coordination, postural balance, and gait. Established outcome parameters related to VOR suppression ability (e.g., gain, saccadic reaction time, frequency of saccades) and motor related fall risk (e.g., step-time variability, postural sway) will be calculated. Falls will be assessed prospectively over 12 months via protocols and monthly telephone interviews. This study protocol describes an experimental setup allowing the analysis of simultaneously assessed eye, head and body movements. Results will improve our understanding of the influence of the interplay between eye, head and body movements on falls in geriatric high-risk cohorts.

  5. Physical Activity Assessment Using an Activity Tracker in Patients with Rheumatoid Arthritis and Axial Spondyloarthritis: Prospective Observational Study

    PubMed Central

    Servy, Hervé; Molto, Anna; Sellam, Jérémie; Foltz, Violaine; Gandjbakhch, Frédérique; Hudry, Christophe; Mitrovic, Stéphane; Fautrel, Bruno; Gossec, Laure

    2018-01-01

    Background Physical activity can be tracked using mobile devices and is recommended in rheumatoid arthritis (RA) and axial spondyloarthritis (axSpA) management. The World Health Organization (WHO) recommends at least 150 min per week of moderate to vigorous physical activity (MVPA). Objective The objectives of this study were to assess and compare physical activity and its patterns in patients with RA and axSpA using an activity tracker and to assess the feasibility of mobile devices in this population. Methods This multicentric prospective observational study (ActConnect) included patients who had definite RA or axSpA, and a smartphone. Physical activity was assessed over 3 months using a mobile activity tracker, recording the number of steps per minute. The number of patients reaching the WHO recommendations was calculated. RA and axSpA were compared, using linear mixed models, for number of steps, proportion of morning steps, duration of total activity, and MVPA. Physical activity trajectories were identified using the K-means method, and factors related to the low activity trajectory were explored by logistic regression. Acceptability was assessed by the mean number of days the tracker was worn over the 3 months (ie, adherence), the percentage of wearing time, and by an acceptability questionnaire. Results A total of 157 patients (83 RA and 74 axSpA) were analyzed; 36.3% (57/157) patients were males, and their mean age was 46 (standard deviation [SD] 12) years and mean disease duration was 11 (SD 9) years. RA and axSpA patients had similar physical activity levels of 16 (SD 11) and 15 (SD 12) min per day of MVPA (P=.80), respectively. Only 27.4% (43/157) patients reached the recommendations with a mean MVPA of 106 (SD 77) min per week. The following three trajectories were identified with constant activity: low (54.1% [85/157] of patients), moderate (42.7% [67/157] of patients), and high (3.2% [5/157] of patients) levels of MVPA. A higher body mass index was significantly related to less physical activity (odds ratio 1.12, 95% CI 1.11-1.14). The activity trackers were worn during a mean of 79 (SD 17) days over the 90 days follow-up. Overall, patients considered the use of the tracker very acceptable, with a mean score of 8 out 10. Conclusions Patients with RA and axSpA performed insufficient physical activity with similar levels in both groups, despite the differences between the 2 diseases. Activity trackers allow longitudinal assessment of physical activity in these patients. The good adherence to this study and the good acceptability of wearing activity trackers confirmed the feasibility of the use of a mobile activity tracker in patients with rheumatic diseases. PMID:29295810

  6. A software module for implementing auditory and visual feedback on a video-based eye tracking system

    NASA Astrophysics Data System (ADS)

    Rosanlall, Bharat; Gertner, Izidor; Geri, George A.; Arrington, Karl F.

    2016-05-01

    We describe here the design and implementation of a software module that provides both auditory and visual feedback of the eye position measured by a commercially available eye tracking system. The present audio-visual feedback module (AVFM) serves as an extension to the Arrington Research ViewPoint EyeTracker, but it can be easily modified for use with other similar systems. Two modes of audio feedback and one mode of visual feedback are provided in reference to a circular area-of-interest (AOI). Auditory feedback can be either a click tone emitted when the user's gaze point enters or leaves the AOI, or a sinusoidal waveform with frequency inversely proportional to the distance from the gaze point to the center of the AOI. Visual feedback is in the form of a small circular light patch that is presented whenever the gaze-point is within the AOI. The AVFM processes data that are sent to a dynamic-link library by the EyeTracker. The AVFM's multithreaded implementation also allows real-time data collection (1 kHz sampling rate) and graphics processing that allow display of the current/past gaze-points as well as the AOI. The feedback provided by the AVFM described here has applications in military target acquisition and personnel training, as well as in visual experimentation, clinical research, marketing research, and sports training.

  7. Towards understanding addiction factors of mobile devices: An eye tracking study on effect of screen size.

    PubMed

    Wibirama, Sunu; Nugroho, Hanung A

    2017-07-01

    Mobile devices addiction has been an important research topic in cognitive science, mental health, and human-machine interaction. Previous works observed mobile device addiction by logging mobile devices activity. Although immersion has been linked as a significant predictor of video game addiction, investigation on addiction factors of mobile device with behavioral measurement has never been done before. In this research, we demonstrated the usage of eye tracking to observe effect of screen size on experience of immersion. We compared subjective judgment with eye movements analysis. Non-parametric analysis on immersion score shows that screen size affects experience of immersion (p<;0.05). Furthermore, our experimental results suggest that fixational eye movements may be used as an indicator for future investigation of mobile devices addiction. Our experimental results are also useful to develop a guideline as well as intervention strategy to deal with smartphone addiction.

  8. Stance Postural Strategies in Patients with Chronic Inflammatory Demyelinating Polyradiculoneuropathy

    PubMed Central

    Missori, Paolo; Trompetto, Carlo; Fattapposta, Francesco

    2016-01-01

    Introduction Polyneuropathy leads to postural instability and an increased risk of falling. We investigated how impaired motor impairment and proprioceptive input due to neuropathy influences postural strategies. Methods Platformless bisegmental posturography data were recorded in healthy subjects and patients with chronic inflammatory demyelinating polyradiculoneuropathy (CIDP). Each subject stood on the floor, wore a head and a hip electromagnetic tracker. Sway amplitude and velocity were recorded and the mean direction difference (MDD) in the velocity vector between trackers was calculated as a flexibility index. Results Head and hip postural sway increased more in patients with CIDP than in healthy controls. MDD values reflecting hip strategies also increased more in patients than in controls. In the eyes closed condition MDD values in healthy subjects decreased but in patients remained unchanged. Discussion Sensori-motor impairment changes the balance between postural strategies that patients adopt to maintain upright quiet stance. Motor impairment leads to hip postural strategy overweight (eyes open), and prevents strategy re-balancing when the sensory context predominantly relies on proprioceptive input (eyes closed). PMID:26977594

  9. Low bandwidth eye tracker for scanning laser ophthalmoscopy

    NASA Astrophysics Data System (ADS)

    Harvey, Zachary G.; Dubra, Alfredo; Cahill, Nathan D.; Lopez Alarcon, Sonia

    2012-02-01

    The incorporation of adaptive optics to scanning ophthalmoscopes (AOSOs) has allowed for in vivo, noninvasive imaging of the human rod and cone photoreceptor mosaics. Light safety restrictions and power limitations of the current low-coherence light sources available for imaging result in each individual raw image having a low signal to noise ratio (SNR). To date, the only approach used to increase the SNR has been to collect large number of raw images (N >50), to register them to remove the distortions due to involuntary eye motion, and then to average them. The large amplitude of involuntary eye motion with respect to the AOSO field of view (FOV) dictates that an even larger number of images need to be collected at each retinal location to ensure adequate SNR over the feature of interest. Compensating for eye motion during image acquisition to keep the feature of interest within the FOV could reduce the number of raw frames required per retinal feature, therefore significantly reduce the imaging time, storage requirements, post-processing times and, more importantly, subject's exposure to light. In this paper, we present a particular implementation of an AOSO, termed the adaptive optics scanning light ophthalmoscope (AOSLO) equipped with a simple eye tracking system capable of compensating for eye drift by estimating the eye motion from the raw frames and by using a tip-tilt mirror to compensate for it in a closed-loop. Multiple control strategies were evaluated to minimize the image distortion introduced by the tracker itself. Also, linear, quadratic and Kalman filter motion prediction algorithms were implemented and tested and tested using both simulated motion (sinusoidal motion with varying frequencies) and human subjects. The residual displacement of the retinal features was used to compare the performance of the different correction strategies and prediction methods.

  10. Improving data retention in EEG research with children using child-centered eye tracking

    PubMed Central

    Maguire, Mandy J.; Magnon, Grant; Fitzhugh, Anna E.

    2014-01-01

    Background Event Related Potentials (ERPs) elicited by visual stimuli have increased our understanding of developmental disorders and adult cognitive abilities for decades; however, these studies are very difficult with populations who cannot sustain visual attention such as infants and young children. Current methods for studying such populations include requiring a button response, which may be impossible for some participants, and experimenter monitoring, which is subject to error, highly variable, and spatially imprecise. New Method We developed a child-centered methodology to integrate EEG data acquisition and eye-tracking technologies that uses “attention-getters” in which stimulus display is contingent upon the child’s gaze. The goal was to increase the number of trials retained. Additionally, we used the eye-tracker to categorize and analyze the EEG data based on gaze to specific areas of the visual display, compared to analyzing based on stimulus presentation. Results Compared with Existing Methods The number of trials retained was substantially improved using the child-centered methodology compared to a button-press response in 7–8 year olds. In contrast, analyzing the EEG based on eye gaze to specific points within the visual display as opposed to stimulus presentation provided too few trials for reliable interpretation. Conclusions By using the linked EEG-eye-tracker we significantly increased data retention. With this method, studies can be completed with fewer participants and a wider range of populations. However, caution should be used when epoching based on participants’ eye gaze because, in this case, this technique provided substantially fewer trials. PMID:25251555

  11. A neural-based remote eye gaze tracker under natural head motion.

    PubMed

    Torricelli, Diego; Conforto, Silvia; Schmid, Maurizio; D'Alessio, Tommaso

    2008-10-01

    A novel approach to view-based eye gaze tracking for human computer interface (HCI) is presented. The proposed method combines different techniques to address the problems of head motion, illumination and usability in the framework of low cost applications. Feature detection and tracking algorithms have been designed to obtain an automatic setup and strengthen the robustness to light conditions. An extensive analysis of neural solutions has been performed to deal with the non-linearity associated with gaze mapping under free-head conditions. No specific hardware, such as infrared illumination or high-resolution cameras, is needed, rather a simple commercial webcam working in visible light spectrum suffices. The system is able to classify the gaze direction of the user over a 15-zone graphical interface, with a success rate of 95% and a global accuracy of around 2 degrees , comparable with the vast majority of existing remote gaze trackers.

  12. Usability Evaluation of Clinical Guidelines on the Web Using Eye-Tracker.

    PubMed

    Khodambashi, Soudabeh; Gilstad, Heidi; Nytrø, Øystein

    2016-01-01

    Publishing clinical guidelines (GLs) on the web increases their accessibility. However, evaluating their usability and understanding how users interact with the websites has been neglected. In this study we used Tobii eye-tracker to analyse users' interaction with five commercial and public GL sites popular in Norway (four in Norwegian and one English of US origin (UpToDate)). We measured number of clicks and usage rate for search functions, task completion time, users' objective and perception of task success rate. We also measured learning effect for inexperienced users. We found a direct correlation between participant's satisfaction regarding website usability and the time spent, number of mouse clicks and use of search function to obtain the desired results. Our study showed that users' perceived success rate was not reliable and GL publishers should evaluate their website regarding presentation format, layout, navigation bar and search function.

  13. On Biometrics With Eye Movements.

    PubMed

    Zhang, Youming; Juhola, Martti

    2017-09-01

    Eye movements are a relatively novel data source for biometric identification. When video cameras applied to eye tracking become smaller and more efficient, this data source could offer interesting opportunities for the development of eye movement biometrics. In this paper, we study primarily biometric identification as seen as a classification task of multiple classes, and secondarily biometric verification considered as binary classification. Our research is based on the saccadic eye movement signal measurements from 109 young subjects. In order to test the data measured, we use a procedure of biometric identification according to the one-versus-one (subject) principle. In a development from our previous research, which also involved biometric verification based on saccadic eye movements, we now apply another eye movement tracker device with a higher sampling frequency of 250 Hz. The results obtained are good, with correct identification rates at 80-90% at their best.

  14. How to Measure Physical Motion and the Impact of Individualized Feedback in the Field of Rehabilitation of Geriatric Trauma Patients.

    PubMed

    Altenbuchner, Amelie; Haug, Sonja; Kretschmer, Rainer; Weber, Karsten

    2018-01-01

    This preparatory study accelerates an implementation of individualized monitoring and feedback of physical motion using conventional motion trackers in the rehabilitation process of geriatric trauma patients. Regaining mobility is accompanied with improved quality of life in persons of very advanced age recovering from fragility fractures. Quantitative survey of regaining physical mobility provides recommendations for action on how to use motion trackers effectively in a clinical geriatric setting. Method mix of quantitative and qualitative interdisciplinary and mutual complementary research approaches (sociology, health research, philosophy/ethics, medical informatics, nursing science, gerontology and physical therapy). While validating motion tracker use in geriatric traumatology preliminary data are used to develop a target group oriented motion feedback. In addition measurement accuracy of a questionnaire about quality of life of multimorbid geriatric patients (FLQM) is tested. Implementing a new technology in a complex clinical setting needs to be based on a strong theoretical background but will not succeed without careful field testing.

  15. Scientific Inquiry, Digital Literacy, and Mobile Computing in Informal Learning Environments

    ERIC Educational Resources Information Center

    Marty, Paul F.; Alemanne, Nicole D.; Mendenhall, Anne; Maurya, Manisha; Southerland, Sherry A.; Sampson, Victor; Douglas, Ian; Kazmer, Michelle M.; Clark, Amanda; Schellinger, Jennifer

    2013-01-01

    Understanding the connections between scientific inquiry and digital literacy in informal learning environments is essential to furthering students' critical thinking and technology skills. The Habitat Tracker project combines a standards-based curriculum focused on the nature of science with an integrated system of online and mobile computing…

  16. Understanding usage of a hybrid website and smartphone app for weight management: a mixed-methods study.

    PubMed

    Morrison, Leanne G; Hargood, Charlie; Lin, Sharon Xiaowen; Dennison, Laura; Joseph, Judith; Hughes, Stephanie; Michaelides, Danius T; Johnston, Derek; Johnston, Marie; Michie, Susan; Little, Paul; Smith, Peter Wf; Weal, Mark J; Yardley, Lucy

    2014-10-22

    Advancements in mobile phone technology offer huge potential for enhancing the timely delivery of health behavior change interventions. The development of smartphone-based health interventions (apps) is a rapidly growing field of research, yet there have been few longitudinal examinations of how people experience and use these apps within their day-to-day routines, particularly within the context of a hybrid Web- and app-based intervention. This study used an in-depth mixed-methods design to examine individual variation in (1) impact on self-reported goal engagement (ie, motivation, self-efficacy, awareness, effort, achievement) of access to a weight management app (POWeR Tracker) when provided alongside a Web-based weight management intervention (POWeR) and (2) usage and views of POWeR Tracker. Thirteen adults were provided access to POWeR and were monitored over a 4-week period. Access to POWeR Tracker was provided in 2 alternate weeks (ie, weeks 1 and 3 or weeks 2 and 4). Participants' goal engagement was measured daily via self-report. Mixed effects models were used to examine change in goal engagement between the weeks when POWeR Tracker was and was not available and whether the extent of change in goal engagement varied between individual participants. Usage of POWeR and POWeR Tracker was automatically recorded for each participant. Telephone interviews were conducted and analyzed using inductive thematic analysis to further explore participants' experiences using POWeR and POWeR Tracker. Access to POWeR Tracker was associated with a significant increase in participants' awareness of their eating (β1=0.31, P=.04) and physical activity goals (β1=0.28, P=.03). The level of increase varied between individual participants. Usage data showed that participants used the POWeR website for similar amounts of time during the weeks when POWeR Tracker was (mean 29 minutes, SD 31 minutes) and was not available (mean 27 minutes, SD 33 minutes). POWeR Tracker was mostly accessed in short bursts (mean 3 minutes, SD 2 minutes) during convenient moments or moments when participants deemed the intervention content most relevant. The qualitative data indicated that nearly all participants agreed that it was more convenient to access information on-the-go via their mobiles compared to a computer. However, participants varied in their views and usage of the Web- versus app-based components and the informational versus tracking tools provided by POWeR Tracker. This study provides evidence that smartphones have the potential to improve individuals' engagement with their health-related goals when used as a supplement to an existing online intervention. The perceived convenience of mobile access to information does not appear to deter use of Web-based interventions or strengthen the impact of app access on goal engagement. A mixed-methods design enabled exploration of individual variation in daily usage of the app-based tools.

  17. Understanding Usage of a Hybrid Website and Smartphone App for Weight Management: A Mixed-Methods Study

    PubMed Central

    Hargood, Charlie; Lin, Sharon Xiaowen; Dennison, Laura; Joseph, Judith; Hughes, Stephanie; Michaelides, Danius T; Johnston, Derek; Johnston, Marie; Michie, Susan; Little, Paul; Smith, Peter WF; Weal, Mark J; Yardley, Lucy

    2014-01-01

    Background Advancements in mobile phone technology offer huge potential for enhancing the timely delivery of health behavior change interventions. The development of smartphone-based health interventions (apps) is a rapidly growing field of research, yet there have been few longitudinal examinations of how people experience and use these apps within their day-to-day routines, particularly within the context of a hybrid Web- and app-based intervention. Objective This study used an in-depth mixed-methods design to examine individual variation in (1) impact on self-reported goal engagement (ie, motivation, self-efficacy, awareness, effort, achievement) of access to a weight management app (POWeR Tracker) when provided alongside a Web-based weight management intervention (POWeR) and (2) usage and views of POWeR Tracker. Methods Thirteen adults were provided access to POWeR and were monitored over a 4-week period. Access to POWeR Tracker was provided in 2 alternate weeks (ie, weeks 1 and 3 or weeks 2 and 4). Participants’ goal engagement was measured daily via self-report. Mixed effects models were used to examine change in goal engagement between the weeks when POWeR Tracker was and was not available and whether the extent of change in goal engagement varied between individual participants. Usage of POWeR and POWeR Tracker was automatically recorded for each participant. Telephone interviews were conducted and analyzed using inductive thematic analysis to further explore participants’ experiences using POWeR and POWeR Tracker. Results Access to POWeR Tracker was associated with a significant increase in participants’ awareness of their eating (β1=0.31, P=.04) and physical activity goals (β1=0.28, P=.03). The level of increase varied between individual participants. Usage data showed that participants used the POWeR website for similar amounts of time during the weeks when POWeR Tracker was (mean 29 minutes, SD 31 minutes) and was not available (mean 27 minutes, SD 33 minutes). POWeR Tracker was mostly accessed in short bursts (mean 3 minutes, SD 2 minutes) during convenient moments or moments when participants deemed the intervention content most relevant. The qualitative data indicated that nearly all participants agreed that it was more convenient to access information on-the-go via their mobiles compared to a computer. However, participants varied in their views and usage of the Web- versus app-based components and the informational versus tracking tools provided by POWeR Tracker. Conclusions This study provides evidence that smartphones have the potential to improve individuals’ engagement with their health-related goals when used as a supplement to an existing online intervention. The perceived convenience of mobile access to information does not appear to deter use of Web-based interventions or strengthen the impact of app access on goal engagement. A mixed-methods design enabled exploration of individual variation in daily usage of the app-based tools. PMID:25355131

  18. Mobile Eye Tracking Methodology in Informal E-Learning in Social Groups in Technology-Enhanced Science Centres

    ERIC Educational Resources Information Center

    Magnussen, Rikke; Zachariassen, Maria; Kharlamov, Nikita; Larsen, Birger

    2017-01-01

    This paper presents a methodological discussion of the potential and challenges of involving mobile eye tracking technology in studies of knowledge generation and learning in a science centre context. The methodological exploration is based on eye-tracking studies of audience interaction and knowledge generation in the technology-enhanced health…

  19. Measuring eye movements during locomotion: filtering techniques for obtaining velocity signals from a video-based eye monitor

    NASA Technical Reports Server (NTRS)

    Das, V. E.; Thomas, C. W.; Zivotofsky, A. Z.; Leigh, R. J.

    1996-01-01

    Video-based eye-tracking systems are especially suited to studying eye movements during naturally occurring activities such as locomotion, but eye velocity records suffer from broad band noise that is not amenable to conventional filtering methods. We evaluated the effectiveness of combined median and moving-average filters by comparing prefiltered and postfiltered records made synchronously with a video eye-tracker and the magnetic search coil technique, which is relatively noise free. Root-mean-square noise was reduced by half, without distorting the eye velocity signal. To illustrate the practical use of this technique, we studied normal subjects and patients with deficient labyrinthine function and compared their ability to hold gaze on a visual target that moved with their heads (cancellation of the vestibulo-ocular reflex). Patients and normal subjects performed similarly during active head rotation but, during locomotion, patients held their eyes more steadily on the visual target than did subjects.

  20. Fully distributed monitoring architecture supporting multiple trackees and trackers in indoor mobile asset management application.

    PubMed

    Jeong, Seol Young; Jo, Hyeong Gon; Kang, Soon Ju

    2014-03-21

    A tracking service like asset management is essential in a dynamic hospital environment consisting of numerous mobile assets (e.g., wheelchairs or infusion pumps) that are continuously relocated throughout a hospital. The tracking service is accomplished based on the key technologies of an indoor location-based service (LBS), such as locating and monitoring multiple mobile targets inside a building in real time. An indoor LBS such as a tracking service entails numerous resource lookups being requested concurrently and frequently from several locations, as well as a network infrastructure requiring support for high scalability in indoor environments. A traditional centralized architecture needs to maintain a geographic map of the entire building or complex in its central server, which can cause low scalability and traffic congestion. This paper presents a self-organizing and fully distributed indoor mobile asset management (MAM) platform, and proposes an architecture for multiple trackees (such as mobile assets) and trackers based on the proposed distributed platform in real time. In order to verify the suggested platform, scalability performance according to increases in the number of concurrent lookups was evaluated in a real test bed. Tracking latency and traffic load ratio in the proposed tracking architecture was also evaluated.

  1. The "EyeCane", a new electronic travel aid for the blind: Technology, behavior & swift learning.

    PubMed

    Maidenbaum, Shachar; Hanassy, Shlomi; Abboud, Sami; Buchs, Galit; Chebat, Daniel-Robert; Levy-Tzedek, Shelly; Amedi, Amir

    2014-01-01

    Independent mobility is one of the most pressing problems facing people who are blind. We present the EyeCane, a new mobility aid aimed at increasing perception of environment beyond what is provided by the traditional White Cane for tasks such as distance estimation, navigation and obstacle detection. The "EyeCane" enhances the traditional White Cane by using tactile and auditory output to increase detectable distance and angles. It circumvents the technical pitfalls of other devices, such as weight, short battery life, complex interface schemes, and slow learning curve. It implements multiple beams to enables detection of obstacles at different heights, and narrow beams to provide active sensing that can potentially increase the user's spatial perception of the environment. Participants were tasked with using the EyeCane for several basic tasks with minimal training. Blind and blindfolded-sighted participants were able to use the EyeCane successfully for distance estimation, simple navigation and simple obstacle detection after only several minutes of training. These results demonstrate the EyeCane's potential for mobility rehabilitation. The short training time is especially important since available mobility training resources are limited, not always available, and can be quite expensive and/or entail long waiting periods.

  2. Automatic Classification of Users’ Health Information Need Context: Logistic Regression Analysis of Mouse-Click and Eye-Tracker Data

    PubMed Central

    Pian, Wenjing; Khoo, Christopher SG

    2017-01-01

    Background Users searching for health information on the Internet may be searching for their own health issue, searching for someone else’s health issue, or browsing with no particular health issue in mind. Previous research has found that these three categories of users focus on different types of health information. However, most health information websites provide static content for all users. If the three types of user health information need contexts can be identified by the Web application, the search results or information offered to the user can be customized to increase its relevance or usefulness to the user. Objective The aim of this study was to investigate the possibility of identifying the three user health information contexts (searching for self, searching for others, or browsing with no particular health issue in mind) using just hyperlink clicking behavior; using eye-tracking information; and using a combination of eye-tracking, demographic, and urgency information. Predictive models are developed using multinomial logistic regression. Methods A total of 74 participants (39 females and 35 males) who were mainly staff and students of a university were asked to browse a health discussion forum, Healthboards.com. An eye tracker recorded their examining (eye fixation) and skimming (quick eye movement) behaviors on 2 types of screens: summary result screen displaying a list of post headers, and detailed post screen. The following three types of predictive models were developed using logistic regression analysis: model 1 used only the time spent in scanning the summary result screen and reading the detailed post screen, which can be determined from the user’s mouse clicks; model 2 used the examining and skimming durations on each screen, recorded by an eye tracker; and model 3 added user demographic and urgency information to model 2. Results An analysis of variance (ANOVA) analysis found that users’ browsing durations were significantly different for the three health information contexts (P<.001). The logistic regression model 3 was able to predict the user’s type of health information context with a 10-fold cross validation mean accuracy of 84% (62/74), followed by model 2 at 73% (54/74) and model 1 at 71% (52/78). In addition, correlation analysis found that particular browsing durations were highly correlated with users’ age, education level, and the urgency of their information need. Conclusions A user’s type of health information need context (ie, searching for self, for others, or with no health issue in mind) can be identified with reasonable accuracy using just user mouse clicks that can easily be detected by Web applications. Higher accuracy can be obtained using Google glass or future computing devices with eye tracking function. PMID:29269342

  3. Human Mobility Monitoring in Very Low Resolution Visual Sensor Network

    PubMed Central

    Bo Bo, Nyan; Deboeverie, Francis; Eldib, Mohamed; Guan, Junzhi; Xie, Xingzhe; Niño, Jorge; Van Haerenborgh, Dirk; Slembrouck, Maarten; Van de Velde, Samuel; Steendam, Heidi; Veelaert, Peter; Kleihorst, Richard; Aghajan, Hamid; Philips, Wilfried

    2014-01-01

    This paper proposes an automated system for monitoring mobility patterns using a network of very low resolution visual sensors (30 × 30 pixels). The use of very low resolution sensors reduces privacy concern, cost, computation requirement and power consumption. The core of our proposed system is a robust people tracker that uses low resolution videos provided by the visual sensor network. The distributed processing architecture of our tracking system allows all image processing tasks to be done on the digital signal controller in each visual sensor. In this paper, we experimentally show that reliable tracking of people is possible using very low resolution imagery. We also compare the performance of our tracker against a state-of-the-art tracking method and show that our method outperforms. Moreover, the mobility statistics of tracks such as total distance traveled and average speed derived from trajectories are compared with those derived from ground truth given by Ultra-Wide Band sensors. The results of this comparison show that the trajectories from our system are accurate enough to obtain useful mobility statistics. PMID:25375754

  4. Effects of third generation mobile phone-emitted electromagnetic radiation on oxidative stress parameters in eye tissue and blood of rats.

    PubMed

    Demirel, Soner; Doganay, Selim; Turkoz, Yusuf; Dogan, Zümrüt; Turan, Bahadir; Firat, Penpe Gul Bozgul

    2012-06-01

    To investigate the effects of electromagnetic radiation (EMR) emitted by a third generation (3G) mobile phone on the antioxidant and oxidative stress parameters in eye tissue and blood of rats. Eighteen Wistar albino rats were randomly assigned into two groups: Group I (n = 9) received a standardized a daily dose of 3G mobile phone EMR for 20 days, and Group II served as the control group (n = 9), receiving no exposure to EMR. Glutathione peroxidase (GSH-Px) and catalase (CAT) levels were measured in eye tissues; in addition, malondialdehyde (MDA) and reduced GSH levels were measured in blood. There was no significant difference between groups in GSH-Px (p = 0.99) and CAT (p = 0.18) activity in eye tissue. There was no significant difference between groups in MDA (p = 0.69) and GSH levels (p = 0.83) in blood. The results of this study suggest that under a short period of exposure, 3G mobile phone radiation does not lead to harmful effects on eye tissue and blood in rats.

  5. Integrated fringe projection 3D scanning system for large-scale metrology based on laser tracker

    NASA Astrophysics Data System (ADS)

    Du, Hui; Chen, Xiaobo; Zhou, Dan; Guo, Gen; Xi, Juntong

    2017-10-01

    Large scale components exist widely in advance manufacturing industry,3D profilometry plays a pivotal role for the quality control. This paper proposes a flexible, robust large-scale 3D scanning system by integrating a robot with a binocular structured light scanner and a laser tracker. The measurement principle and system construction of the integrated system are introduced. And a mathematical model is established for the global data fusion. Subsequently, a flexible and robust method and mechanism is introduced for the establishment of the end coordination system. Based on this method, a virtual robot noumenon is constructed for hand-eye calibration. And then the transformation matrix between end coordination system and world coordination system is solved. Validation experiment is implemented for verifying the proposed algorithms. Firstly, hand-eye transformation matrix is solved. Then a car body rear is measured for 16 times for the global data fusion algorithm verification. And the 3D shape of the rear is reconstructed successfully.

  6. Wearing a Bicycle Helmet Can Increase Risk Taking and Sensation Seeking in Adults

    PubMed Central

    Gamble, Tim; Walker, Ian

    2016-01-01

    Humans adapt their risk-taking behavior on the basis of perceptions of safety; this risk-compensation phenomenon is typified by people taking increased risks when using protective equipment. Existing studies have looked at people who know they are using safety equipment and have specifically focused on changes in behaviors for which that equipment might reduce risk. Here, we demonstrated that risk taking increases in people who are not explicitly aware they are wearing protective equipment; furthermore, this happens for behaviors that could not be made safer by that equipment. In a controlled study in which a helmet, compared with a baseball cap, was used as the head mount for an eye tracker, participants scored significantly higher on laboratory measures of both risk taking and sensation seeking. This happened despite there being no risk for the helmet to ameliorate and despite it being introduced purely as an eye tracker. The results suggest that unconscious activation of safety-related concepts primes globally increased risk propensity. PMID:26740528

  7. Gender Classification Based on Eye Movements: A Processing Effect During Passive Face Viewing

    PubMed Central

    Sammaknejad, Negar; Pouretemad, Hamidreza; Eslahchi, Changiz; Salahirad, Alireza; Alinejad, Ashkan

    2017-01-01

    Studies have revealed superior face recognition skills in females, partially due to their different eye movement strategies when encoding faces. In the current study, we utilized these slight but important differences and proposed a model that estimates the gender of the viewers and classifies them into two subgroups, males and females. An eye tracker recorded participant’s eye movements while they viewed images of faces. Regions of interest (ROIs) were defined for each face. Results showed that the gender dissimilarity in eye movements was not due to differences in frequency of fixations in the ROI s per se. Instead, it was caused by dissimilarity in saccade paths between the ROIs. The difference enhanced when saccades were towards the eyes. Females showed significant increase in transitions from other ROI s to the eyes. Consequently, the extraction of temporal transient information of saccade paths through a transition probability matrix, similar to a first order Markov chain model, significantly improved the accuracy of the gender classification results. PMID:29071007

  8. Gender Classification Based on Eye Movements: A Processing Effect During Passive Face Viewing.

    PubMed

    Sammaknejad, Negar; Pouretemad, Hamidreza; Eslahchi, Changiz; Salahirad, Alireza; Alinejad, Ashkan

    2017-01-01

    Studies have revealed superior face recognition skills in females, partially due to their different eye movement strategies when encoding faces. In the current study, we utilized these slight but important differences and proposed a model that estimates the gender of the viewers and classifies them into two subgroups, males and females. An eye tracker recorded participant's eye movements while they viewed images of faces. Regions of interest (ROIs) were defined for each face. Results showed that the gender dissimilarity in eye movements was not due to differences in frequency of fixations in the ROI s per se. Instead, it was caused by dissimilarity in saccade paths between the ROIs. The difference enhanced when saccades were towards the eyes. Females showed significant increase in transitions from other ROI s to the eyes. Consequently, the extraction of temporal transient information of saccade paths through a transition probability matrix, similar to a first order Markov chain model, significantly improved the accuracy of the gender classification results.

  9. Development of a novel visuomotor integration paradigm by integrating a virtual environment with mobile eye-tracking and motion-capture systems

    PubMed Central

    Miller, Haylie L.; Bugnariu, Nicoleta; Patterson, Rita M.; Wijayasinghe, Indika; Popa, Dan O.

    2018-01-01

    Visuomotor integration (VMI), the use of visual information to guide motor planning, execution, and modification, is necessary for a wide range of functional tasks. To comprehensively, quantitatively assess VMI, we developed a paradigm integrating virtual environments, motion-capture, and mobile eye-tracking. Virtual environments enable tasks to be repeatable, naturalistic, and varied in complexity. Mobile eye-tracking and minimally-restricted movement enable observation of natural strategies for interacting with the environment. This paradigm yields a rich dataset that may inform our understanding of VMI in typical and atypical development. PMID:29876370

  10. Visual Fatigue Induced by Viewing a Tablet Computer with a High-resolution Display.

    PubMed

    Kim, Dong Ju; Lim, Chi Yeon; Gu, Namyi; Park, Choul Yong

    2017-10-01

    In the present study, the visual discomfort induced by smart mobile devices was assessed in normal and healthy adults. Fifty-nine volunteers (age, 38.16 ± 10.23 years; male : female = 19 : 40) were exposed to tablet computer screen stimuli (iPad Air, Apple Inc.) for 1 hour. Participants watched a movie or played a computer game on the tablet computer. Visual fatigue and discomfort were assessed using an asthenopia questionnaire, tear film break-up time, and total ocular wavefront aberration before and after viewing smart mobile devices. Based on the questionnaire, viewing smart mobile devices for 1 hour significantly increased mean total asthenopia score from 19.59 ± 8.58 to 22.68 ± 9.39 (p < 0.001). Specifically, the scores for five items (tired eyes, sore/aching eyes, irritated eyes, watery eyes, and hot/burning eye) were significantly increased by viewing smart mobile devices. Tear film break-up time significantly decreased from 5.09 ± 1.52 seconds to 4.63 ± 1.34 seconds (p = 0.003). However, total ocular wavefront aberration was unchanged. Visual fatigue and discomfort were significantly induced by viewing smart mobile devices, even though the devices were equipped with state-of-the-art display technology. © 2017 The Korean Ophthalmological Society

  11. Visual Fatigue Induced by Viewing a Tablet Computer with a High-resolution Display

    PubMed Central

    Kim, Dong Ju; Lim, Chi-Yeon; Gu, Namyi

    2017-01-01

    Purpose In the present study, the visual discomfort induced by smart mobile devices was assessed in normal and healthy adults. Methods Fifty-nine volunteers (age, 38.16 ± 10.23 years; male : female = 19 : 40) were exposed to tablet computer screen stimuli (iPad Air, Apple Inc.) for 1 hour. Participants watched a movie or played a computer game on the tablet computer. Visual fatigue and discomfort were assessed using an asthenopia questionnaire, tear film break-up time, and total ocular wavefront aberration before and after viewing smart mobile devices. Results Based on the questionnaire, viewing smart mobile devices for 1 hour significantly increased mean total asthenopia score from 19.59 ± 8.58 to 22.68 ± 9.39 (p < 0.001). Specifically, the scores for five items (tired eyes, sore/aching eyes, irritated eyes, watery eyes, and hot/burning eye) were significantly increased by viewing smart mobile devices. Tear film break-up time significantly decreased from 5.09 ± 1.52 seconds to 4.63 ± 1.34 seconds (p = 0.003). However, total ocular wavefront aberration was unchanged. Conclusions Visual fatigue and discomfort were significantly induced by viewing smart mobile devices, even though the devices were equipped with state-of-the-art display technology. PMID:28914003

  12. Mobile Home Protection Act

    THOMAS, 112th Congress

    Rep. Filner, Bob [D-CA-51

    2011-01-19

    House - 03/23/2011 Referred to the Subcommittee on Insurance, Housing and Community Opportunity. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  13. Quiet eye training facilitates competitive putting performance in elite golfers.

    PubMed

    Vine, Samuel J; Moore, Lee J; Wilson, Mark R

    2011-01-01

    The aim of this study was to examine the effectiveness of a brief quiet eye (QE) training intervention aimed at optimizing visuomotor control and putting performance of elite golfers under pressure, and in real competition. Twenty-two elite golfers (mean handicap 2.7) recorded putting statistics over 10 rounds of competitive golf before attending training individually. Having been randomly assigned to either a QE training or Control group, participants were fitted with an Applied Science Laboratories Mobile Eye tracker and performed 20 baseline (pre-test) putts from 10 ft. Training consisted of video feedback of their gaze behavior while they completed 20 putts; however the QE-trained group received additional instructions related to maintaining a longer QE period. Participants then recorded their putting statistics over a further 10 competitive rounds and re-visited the laboratory for retention and pressure tests of their visuomotor control and putting performance. Overall, the results were supportive of the efficacy of the QE training intervention. QE duration predicted 43% of the variance in putting performance, underlying its critical role in the visuomotor control of putting. The QE-trained group maintained their optimal QE under pressure conditions, whereas the Control group experienced reductions in QE when anxious, with subsequent effects on performance. Although their performance was similar in the pre-test, the QE-trained group holed more putts and left the ball closer to the hole on missed putts than their Control group counterparts in the pressure test. Importantly, these advantages transferred to the golf course, where QE-trained golfers made 1.9 fewer putts per round, compared to pre-training, whereas the Control group showed no change in their putting statistics. These results reveal that QE training, incorporated into a pre-shot routine, is an effective intervention to help golfers maintain control when anxious.

  14. Parent Perception of Two Eye-Gaze Control Technology Systems in Young Children with Cerebral Palsy: Pilot Study.

    PubMed

    Karlsson, Petra; Wallen, Margaret

    2017-01-01

    Eye-gaze control technology enables people with significant physical disability to access computers for communication, play, learning and environmental control. This pilot study used a multiple case study design with repeated baseline assessment and parents' evaluations to compare two eye-gaze control technology systems to identify any differences in factors such as ease of use and impact of the systems for their young children. Five children, aged 3 to 5 years, with dyskinetic cerebral palsy, and their families participated. Overall, families were satisfied with both the Tobii PCEye Go and myGaze® eye tracker, found them easy to position and use, and children learned to operate them quickly. This technology provides young children with important opportunities for learning, play, leisure, and developing communication.

  15. Development and Verification of a Novel Robot-Integrated Fringe Projection 3D Scanning System for Large-Scale Metrology.

    PubMed

    Du, Hui; Chen, Xiaobo; Xi, Juntong; Yu, Chengyi; Zhao, Bao

    2017-12-12

    Large-scale surfaces are prevalent in advanced manufacturing industries, and 3D profilometry of these surfaces plays a pivotal role for quality control. This paper proposes a novel and flexible large-scale 3D scanning system assembled by combining a robot, a binocular structured light scanner and a laser tracker. The measurement principle and system construction of the integrated system are introduced. A mathematical model is established for the global data fusion. Subsequently, a robust method is introduced for the establishment of the end coordinate system. As for hand-eye calibration, the calibration ball is observed by the scanner and the laser tracker simultaneously. With this data, the hand-eye relationship is solved, and then an algorithm is built to get the transformation matrix between the end coordinate system and the world coordinate system. A validation experiment is designed to verify the proposed algorithms. Firstly, a hand-eye calibration experiment is implemented and the computation of the transformation matrix is done. Then a car body rear is measured 22 times in order to verify the global data fusion algorithm. The 3D shape of the rear is reconstructed successfully. To evaluate the precision of the proposed method, a metric tool is built and the results are presented.

  16. I spy with my little eye: cognitive processing of framed physical activity messages.

    PubMed

    Bassett-Gunter, Rebecca L; Latimer-Cheung, Amy E; Martin Ginis, Kathleen A; Castelhano, Monica

    2014-01-01

    The primary purpose was to examine the relative cognitive processing of gain-framed versus loss-framed physical activity messages following exposure to health risk information. Guided by the Extended Parallel Process Model, the secondary purpose was to examine the relation between dwell time, message recall, and message-relevant thoughts, as well as perceived risk, personal relevance, and fear arousal. Baseline measures of perceived risk for inactivity-related disease and health problems were administered to 77 undergraduate students. Participants read population-specific health risk information while wearing a head-mounted eye tracker, which measured dwell time on message content. Perceived risk was then reassessed. Next, participants read PA messages while the eye tracker measured dwell time on message content. Immediately following message exposure, recall, thought-listing, fear arousal, and personal relevance were measured. Dwell time on gain-framed messages was significantly greater than loss-framed messages. However, message recall and thought-listing did not differ by message frame. Dwell time was not significantly related to recall or thought-listing. Consistent with the Extended Parallel Process Model, fear arousal was significantly related to recall, thought-listing, and personal relevance. In conclusion, gain-framed messages may evoke greater dwell time than loss-famed messages. However, dwell time alone may be insufficient for evoking further cognitive processing.

  17. National Freight Mobility Infrastructure Act

    THOMAS, 112th Congress

    Rep. Smith, Adam [D-WA-9

    2011-12-08

    House - 12/09/2011 Referred to the Subcommittee on Railroads, Pipelines, and Hazardous Materials. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  18. Fully Distributed Monitoring Architecture Supporting Multiple Trackees and Trackers in Indoor Mobile Asset Management Application

    PubMed Central

    Jeong, Seol Young; Jo, Hyeong Gon; Kang, Soon Ju

    2014-01-01

    A tracking service like asset management is essential in a dynamic hospital environment consisting of numerous mobile assets (e.g., wheelchairs or infusion pumps) that are continuously relocated throughout a hospital. The tracking service is accomplished based on the key technologies of an indoor location-based service (LBS), such as locating and monitoring multiple mobile targets inside a building in real time. An indoor LBS such as a tracking service entails numerous resource lookups being requested concurrently and frequently from several locations, as well as a network infrastructure requiring support for high scalability in indoor environments. A traditional centralized architecture needs to maintain a geographic map of the entire building or complex in its central server, which can cause low scalability and traffic congestion. This paper presents a self-organizing and fully distributed indoor mobile asset management (MAM) platform, and proposes an architecture for multiple trackees (such as mobile assets) and trackers based on the proposed distributed platform in real time. In order to verify the suggested platform, scalability performance according to increases in the number of concurrent lookups was evaluated in a real test bed. Tracking latency and traffic load ratio in the proposed tracking architecture was also evaluated. PMID:24662407

  19. Effect of limbal marking prior to laser ablation on the magnitude of cyclotorsional error.

    PubMed

    Chen, Xiangjun; Stojanovic, Aleksandar; Stojanovic, Filip; Eidet, Jon Roger; Raeder, Sten; Øritsland, Haakon; Utheim, Tor Paaske

    2012-05-01

    To evaluate the residual registration error after limbal-marking-based manual adjustment in cyclotorsional tracker-controlled laser refractive surgery. Two hundred eyes undergoing custom surface ablation with the iVIS Suite (iVIS Technologies) were divided into limbal marked (marked) and non-limbal marked (unmarked) groups. Iris registration information was acquired preoperatively from all eyes. Preoperatively, the horizontal axis was recorded in the marked group for use in manual cyclotorsional alignment prior to surgical iris registration. During iris registration, the preoperative iris information was compared to the eye-tracker captured image. The magnitudes of the registration error angle and cyclotorsional movement during the subsequent laser ablation were recorded and analyzed. Mean magnitude of registration error angle (absolute value) was 1.82°±1.31° (range: 0.00° to 5.50°) and 2.90°±2.40° (range: 0.00° to 13.50°) for the marked and unmarked groups, respectively (P<.001). Mean magnitude of cyclotorsional movement during the laser ablation (absolute value) was 1.15°±1.34° (range: 0.00° to 7.00°) and 0.68°±0.97° (range: 0.00° to 6.00°) for the marked and unmarked groups, respectively (P=.005). Forty-six percent and 60% of eyes had registration error >2°, whereas 22% and 20% of eyes had cyclotorsional movement during ablation >2° in the marked and unmarked groups, respectively. Limbal-marking-based manual alignment prior to laser ablation significantly reduced cyclotorsional registration error. However, residual registration misalignment and cyclotorsional movements remained during ablation. Copyright 2012, SLACK Incorporated.

  20. Benefits of Motion in Animated Storybooks for Children’s Visual Attention and Story Comprehension. An Eye-Tracking Study

    PubMed Central

    Takacs, Zsofia K.; Bus, Adriana G.

    2016-01-01

    The present study provides experimental evidence regarding 4–6-year-old children’s visual processing of animated versus static illustrations in storybooks. Thirty nine participants listened to an animated and a static book, both three times, while eye movements were registered with an eye-tracker. Outcomes corroborate the hypothesis that specifically motion is what attracts children’s attention while looking at illustrations. It is proposed that animated illustrations that are well matched to the text of the story guide children to those parts of the illustration that are important for understanding the story. This may explain why animated books resulted in better comprehension than static books. PMID:27790183

  1. Visual field recovery after vision restoration therapy (VRT) is independent of eye movements: an eye tracker study.

    PubMed

    Kasten, Erich; Bunzenthal, Ulrike; Sabel, Bernhard A

    2006-11-25

    It has been argued that patients with visual field defects compensate for their deficit by making more frequent eye movements toward the hemianopic field and that visual field enlargements found after vision restoration therapy (VRT) may be an artefact of such eye movements. In order to determine if this was correct, we recorded eye movements in hemianopic subjects before and after VRT. Visual fields were measured in subjects with homonymous visual field defects (n=15) caused by trauma, cerebral ischemia or haemorrhage (lesion age >6 months). Visual field charts were plotted using both high-resolution perimetry (HRP) and conventional perimetry before and after a 3-month period of VRT, with eye movements being recorded with a 2D-eye tracker. This permitted quantification of eye positions and measurements of deviation from fixation. VRT lead to significant visual field enlargements as indicated by an increase of stimulus detection of 3.8% when tested using HRP and about 2.2% (OD) and 3.5% (OS) fewer misses with conventional perimetry. Eye movements were expressed as the standard deviations (S.D.) of the eye position recordings from fixation. Before VRT, the S.D. was +/-0.82 degrees horizontally and +/-1.16 degrees vertically; after VRT, it was +/-0.68 degrees and +/-1.39 degrees , respectively. A cluster analysis of the horizontal eye movements before VRT showed three types of subjects with (i) small (n=7), (ii) medium (n=7) or (iii) large fixation instability (n=1). Saccades were directed equally to the right or the left side; i.e., with no preference toward the blind hemifield. After VRT, many subjects showed a smaller variability of horizontal eye movements. Before VRT, 81.6% of the recorded eye positions were found within a range of 1 degrees horizontally from fixation, whereas after VRT, 88.3% were within that range. In the 2 degrees range, we found 94.8% before and 98.9% after VRT. Subjects moved their eyes 5 degrees or more 0.3% of the time before VRT versus 0.1% after VRT. Thus, in this study, subjects with homonymous visual field defects who were attempting to fixate a central target while their fields were being plotted, typically showed brief horizontal shifts with no preference toward or away from the blind hemifield. These eye movements were usually less than 1 degrees from fixation. Large saccades toward the blind field after VRT were very rare. VRT has no effect on either the direction or the amplitude of horizontal eye movements during visual field testing. These results argue against the theory that the visual field enlargements are artefacts induced by eye movements.

  2. System for assisted mobility using eye movements based on electrooculography.

    PubMed

    Barea, Rafael; Boquete, Luciano; Mazo, Manuel; López, Elena

    2002-12-01

    This paper describes an eye-control method based on electrooculography (EOG) to develop a system for assisted mobility. One of its most important features is its modularity, making it adaptable to the particular needs of each user according to the type and degree of handicap involved. An eye model based on electroculographic signal is proposed and its validity is studied. Several human-machine interfaces (HMI) based on EOG are commented, focusing our study on guiding and controlling a wheelchair for disabled people, where the control is actually effected by eye movements within the socket. Different techniques and guidance strategies are then shown with comments on the advantages and disadvantages of each one. The system consists of a standard electric wheelchair with an on-board computer, sensors and a graphic user interface run by the computer. On the other hand, this eye-control method can be applied to handle graphical interfaces, where the eye is used as a mouse computer. Results obtained show that this control technique could be useful in multiple applications, such as mobility and communication aid for handicapped persons.

  3. The first impression is what matters: a neuroaesthetic study of the cerebral perception and appreciation of paintings by Titian.

    PubMed

    Babiloni, Francesca; Rossi, Dario; Cherubino, Patrizia; Trettel, Arianna; Picconi, Daniela; Maglione, Anton Giulio; Vecchiato, Giovanni; de Vico Fallani, Fabrizio; Chavez, Mario; Babiloni, Fabio

    2015-08-01

    In this paper we measured the neuroelectrical and the eye-movements activities in a group of 27 healthy subjects during their visit of a fine arts gallery in which a series of masterpieces of the Italian painter Tiziano Vecellio (also known as Titian, 1488-1576) were shown. The pictures chosen for the visit were 10 portraits and 10 of religious subjects. Each picture was observed for a minute. A mobile EEG device with an eye-tracker was used for this experiment. Evaluation of the appreciation of the pictures was performed by using the neuroelectrical approach-withdrawal index (AW). High value of AW means high appreciation of the picture. The number of eye fixations performed by the subjects during the observation of the pictures was also analyzed. Results showed that in the examined group the AW index was significant higher during the observation of portraits than during the observation of the religious subjects (as resulted from an ANOVA performed on AW index, with a p<;0,007). Interestingly, the average AW index estimated in the first 20 seconds of the observation of the pictures remains highly correlated with the AW index evaluated for the second part of the data (from 20 s to one minute) for all the 20 pictures examined (r = 0,82, p<;0,0001). In addition, the number of eye fixations performed by the subjects in the first 5 or 10 seconds of observation of the pictures that were most appreciated are significantly higher than the number of eye fixations performed on pictures that subjects did not like (p<;0,048 and p<;0,0018, respectively). Such difference vanishes if the entire period of observation of the pictures of one minute is used (p = 0,54). Taken together, such results seem to suggest that the neuroelectrical correlates of the perception of "good" or "bad" pictures are rapidly formed in our brain, within the first 10-20 seconds from the exposition to the picture.

  4. Facial perception of conspecifics: chimpanzees (Pan troglodytes) preferentially attend to proper orientation and open eyes.

    PubMed

    Hirata, Satoshi; Fuwa, Koki; Sugama, Keiko; Kusunoki, Kiyo; Fujita, Shin

    2010-09-01

    This paper reports on the use of an eye-tracking technique to examine how chimpanzees look at facial photographs of conspecifics. Six chimpanzees viewed a sequence of pictures presented on a monitor while their eye movements were measured by an eye tracker. The pictures presented conspecific faces with open or closed eyes in an upright or inverted orientation in a frame. The results demonstrated that chimpanzees looked at the eyes, nose, and mouth more frequently than would be expected on the basis of random scanning of faces. More specifically, they looked at the eyes longer than they looked at the nose and mouth when photographs of upright faces with open eyes were presented, suggesting that particular attention to the eyes represents a spontaneous face-scanning strategy shared among monkeys, apes, and humans. In contrast to the results obtained for upright faces with open eyes, the viewing times for the eyes, nose, and mouth of inverted faces with open eyes did not differ from one another. The viewing times for the eyes, nose, and mouth of faces with closed eyes did not differ when faces with closed eyes were presented in either an upright or inverted orientation. These results suggest the possibility that open eyes play an important role in the configural processing of faces and that chimpanzees perceive and process open and closed eyes differently.

  5. Relationship between abstract thinking and eye gaze pattern in patients with schizophrenia.

    PubMed

    Oh, Jooyoung; Chun, Ji-Won; Lee, Jung Suk; Kim, Jae-Jin

    2014-04-16

    Effective integration of visual information is necessary to utilize abstract thinking, but patients with schizophrenia have slow eye movement and usually explore limited visual information. This study examines the relationship between abstract thinking ability and the pattern of eye gaze in patients with schizophrenia using a novel theme identification task. Twenty patients with schizophrenia and 22 healthy controls completed the theme identification task, in which subjects selected which word, out of a set of provided words, best described the theme of a picture. Eye gaze while performing the task was recorded by the eye tracker. Patients exhibited a significantly lower correct rate for theme identification and lesser fixation and saccade counts than controls. The correct rate was significantly correlated with the fixation count in patients, but not in controls. Patients with schizophrenia showed impaired abstract thinking and decreased quality of gaze, which were positively associated with each other. Theme identification and eye gaze appear to be useful as tools for the objective measurement of abstract thinking in patients with schizophrenia.

  6. Automatic Classification of Users' Health Information Need Context: Logistic Regression Analysis of Mouse-Click and Eye-Tracker Data.

    PubMed

    Pian, Wenjing; Khoo, Christopher Sg; Chi, Jianxing

    2017-12-21

    Users searching for health information on the Internet may be searching for their own health issue, searching for someone else's health issue, or browsing with no particular health issue in mind. Previous research has found that these three categories of users focus on different types of health information. However, most health information websites provide static content for all users. If the three types of user health information need contexts can be identified by the Web application, the search results or information offered to the user can be customized to increase its relevance or usefulness to the user. The aim of this study was to investigate the possibility of identifying the three user health information contexts (searching for self, searching for others, or browsing with no particular health issue in mind) using just hyperlink clicking behavior; using eye-tracking information; and using a combination of eye-tracking, demographic, and urgency information. Predictive models are developed using multinomial logistic regression. A total of 74 participants (39 females and 35 males) who were mainly staff and students of a university were asked to browse a health discussion forum, Healthboards.com. An eye tracker recorded their examining (eye fixation) and skimming (quick eye movement) behaviors on 2 types of screens: summary result screen displaying a list of post headers, and detailed post screen. The following three types of predictive models were developed using logistic regression analysis: model 1 used only the time spent in scanning the summary result screen and reading the detailed post screen, which can be determined from the user's mouse clicks; model 2 used the examining and skimming durations on each screen, recorded by an eye tracker; and model 3 added user demographic and urgency information to model 2. An analysis of variance (ANOVA) analysis found that users' browsing durations were significantly different for the three health information contexts (P<.001). The logistic regression model 3 was able to predict the user's type of health information context with a 10-fold cross validation mean accuracy of 84% (62/74), followed by model 2 at 73% (54/74) and model 1 at 71% (52/78). In addition, correlation analysis found that particular browsing durations were highly correlated with users' age, education level, and the urgency of their information need. A user's type of health information need context (ie, searching for self, for others, or with no health issue in mind) can be identified with reasonable accuracy using just user mouse clicks that can easily be detected by Web applications. Higher accuracy can be obtained using Google glass or future computing devices with eye tracking function. ©Wenjing Pian, Christopher SG Khoo, Jianxing Chi. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 21.12.2017.

  7. Mobile gaze tracking system for outdoor walking behavioral studies

    PubMed Central

    Tomasi, Matteo; Pundlik, Shrinivas; Bowers, Alex R.; Peli, Eli; Luo, Gang

    2016-01-01

    Most gaze tracking techniques estimate gaze points on screens, on scene images, or in confined spaces. Tracking of gaze in open-world coordinates, especially in walking situations, has rarely been addressed. We use a head-mounted eye tracker combined with two inertial measurement units (IMU) to track gaze orientation relative to the heading direction in outdoor walking. Head movements relative to the body are measured by the difference in output between the IMUs on the head and body trunk. The use of the IMU pair reduces the impact of environmental interference on each sensor. The system was tested in busy urban areas and allowed drift compensation for long (up to 18 min) gaze recording. Comparison with ground truth revealed an average error of 3.3° while walking straight segments. The range of gaze scanning in walking is frequently larger than the estimation error by about one order of magnitude. Our proposed method was also tested with real cases of natural walking and it was found to be suitable for the evaluation of gaze behaviors in outdoor environments. PMID:26894511

  8. An Electronic Pillbox for Continuous Monitoring of Medication Adherence

    PubMed Central

    Hayes, Tamara. L.; Hunt, John M.; Adami, Andre; Kaye, Jeffrey A.

    2010-01-01

    We have developed an instrumented pillbox, called a MedTracker, which allows monitoring of medication adherence on a continuous basis. This device improves on existing systems by providing mobility, frequent and automatic data collection, more detailed information about nonadherence and medication errors, and the familiar interface of a 7-day drug store pillbox. We report on the design of the MedTracker, and on the results of a field trial in 39 homes to evaluate the device. PMID:17946369

  9. Consumer Mobile Fairness Act of 2011

    THOMAS, 112th Congress

    Sen. Blumenthal, Richard [D-CT

    2011-10-04

    Senate - 10/13/2011 Committee on the Judiciary. Hearings held. Hearings printed: S.Hrg. 112-177. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  10. Pre-Paid Mobile Device Identification Act

    THOMAS, 111th Congress

    Sen. Schumer, Charles E. [D-NY

    2010-05-26

    Senate - 05/26/2010 Read twice and referred to the Committee on Commerce, Science, and Transportation. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  11. Bardet-Biedl Syndrome

    MedlinePlus

    ... in Your Area Stories of Hope Videos Resources Low Vision Specialists Retinal Physicians My Retina Tracker Registry Genetic ... worsens, individuals will benefit from the use of low-vision aids and orientation as well as from mobility ...

  12. Mobile, Multi-modal, Label-Free Imaging Probe Analysis of Choroidal Oximetry and Retinal Hypoxia

    DTIC Science & Technology

    2015-10-01

    eyes and image choroidal vessels/capillaries using CARS intravital microscopy Subtask 3: Measure oxy-hemoglobin levels in PBI test and control eyes...AWARD NUMBER: W81XWH-14-1-0537 TITLE: Mobile, Multi-modal, Label-Free Imaging Probe Analysis of Choroidal Oximetry and Retinal Hypoxia...4. TITLE AND SUBTITLE Mobile, Multimodal, Label-Free Imaging Probe Analysis of Choroidal Oximetry and Retinal Hypoxia 5a. CONTRACT NUMBER W81XWH

  13. Moving Ahead With Eye Power

    NASA Technical Reports Server (NTRS)

    2002-01-01

    NASA's Jet Propulsion Laboratory's collaborated with LC Technologies, Inc., to improve LCT's Eyegaze Communication System, an eye tracker that enables people with severe cerebral palsy, muscular dystrophy, multiple sclerosis, strokes, brain injuries, spinal cord injuries, and ALS (amyotrophic lateral sclerosis) to communicate and control their environment using their eye movements. To operate the system, the user sits in front of the computer monitor while the camera focuses on one eye. By looking at control keys on the monitor for a fraction of a second, the user can 'talk' with speech synthesis, type, operate a telephone, access the Internet and e-mail, and run computer software. Nothing is attached to the user's head or body, and the improved size and portability allow the system to be mounted on a wheelchair. LCT and JPL are working on several other areas of improvement that have commercial add-on potential.

  14. Evaluation of an eye-pointer interaction device for human-computer interaction.

    PubMed

    Cáceres, Enrique; Carrasco, Miguel; Ríos, Sebastián

    2018-03-01

    Advances in eye-tracking technology have led to better human-computer interaction, and involve controlling a computer without any kind of physical contact. This research describes the transformation of a commercial eye-tracker for use as an alternative peripheral device in human-computer interactions, implementing a pointer that only needs the eye movements of a user facing a computer screen, thus replacing the need to control the software by hand movements. The experiment was performed with 30 test individuals who used the prototype with a set of educational videogames. The results show that, although most of the test subjects would prefer a mouse to control the pointer, the prototype tested has an empirical precision similar to that of the mouse, either when trying to control its movements or when attempting to click on a point of the screen.

  15. Gaze entropy reflects surgical task load.

    PubMed

    Di Stasi, Leandro L; Diaz-Piedra, Carolina; Rieiro, Héctor; Sánchez Carrión, José M; Martin Berrido, Mercedes; Olivares, Gonzalo; Catena, Andrés

    2016-11-01

    Task (over-)load imposed on surgeons is a main contributing factor to surgical errors. Recent research has shown that gaze metrics represent a valid and objective index to asses operator task load in non-surgical scenarios. Thus, gaze metrics have the potential to improve workplace safety by providing accurate measurements of task load variations. However, the direct relationship between gaze metrics and surgical task load has not been investigated yet. We studied the effects of surgical task complexity on the gaze metrics of surgical trainees. We recorded the eye movements of 18 surgical residents, using a mobile eye tracker system, during the performance of three high-fidelity virtual simulations of laparoscopic exercises of increasing complexity level: Clip Applying exercise, Cutting Big exercise, and Translocation of Objects exercise. We also measured performance accuracy and subjective rating of complexity. Gaze entropy and velocity linearly increased with increased task complexity: Visual exploration pattern became less stereotyped (i.e., more random) and faster during the more complex exercises. Residents performed better the Clip Applying exercise and the Cutting Big exercise than the Translocation of Objects exercise and their perceived task complexity differed accordingly. Our data show that gaze metrics are a valid and reliable surgical task load index. These findings have potential impacts to improve patient safety by providing accurate measurements of surgeon task (over-)load and might provide future indices to assess residents' learning curves, independently of expensive virtual simulators or time-consuming expert evaluation.

  16. Freedom and Mobility in Consumer Banking Act

    THOMAS, 113th Congress

    Sen. Harkin, Tom [D-IA

    2013-09-19

    Senate - 09/19/2013 Read twice and referred to the Committee on Banking, Housing, and Urban Affairs. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  17. Ending Mobile Phone Welfare Act of 2013

    THOMAS, 113th Congress

    Sen. Vitter, David [R-LA

    2013-05-07

    Senate - 05/07/2013 Read twice and referred to the Committee on Commerce, Science, and Transportation. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  18. The Influence of Shyness on the Scanning of Own- and Other-Race Faces in Adults

    PubMed Central

    Wang, Qiandong; Hu, Chao; Short, Lindsey A.; Fu, Genyue

    2012-01-01

    The current study explored the relationship between shyness and face scanning patterns for own- and other-race faces in adults. Participants completed a shyness inventory and a face recognition task in which their eye movements were recorded by a Tobii 1750 eye tracker. We found that: (1) Participants’ shyness scores were negatively correlated with the fixation proportion on the eyes, regardless of the race of face they viewed. The shyer the participants were, the less time they spent fixating on the eye region; (2) High shyness participants tended to fixate significantly more than low shyness participants on the regions just below the eyes as if to avoid direct eye contact; (3) When participants were recognizing own-race faces, their shyness scores were positively correlated with the normalized criterion. The shyer they were, the more apt they were to judge the faces as novel, regardless of whether they were target or foil faces. The present results support an avoidance hypothesis of shyness, suggesting that shy individuals tend to avoid directly fixating on others’ eyes, regardless of face race. PMID:23284933

  19. Secondary reconstruction of a mobile eye socket 30 years after enucleation of the eyeball for retinoblastoma: a case report.

    PubMed

    Okumoto, T; Koike, G; Yoshimura, Y

    2014-03-01

    A mobile eye socket is generally reconstructed by inserting an implant into the scleral pocket immediately after bulbar exenteration, or by attaching the extra-ocular muscles to the implanted artificial eyeball immediately after enucleation. However, exposure of the implanted material and other problems can occur. We achieved satisfactory reconstruction of a mobile eye socket by using an autogenous cartilage graft and a pericranial flap in a patient with long-standing anophthalmia due to enucleation. This case is presented with a review of the relevant literature. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Mobility experiments with microrobots for minimally invasive intraocular surgery.

    PubMed

    Ullrich, Franziska; Bergeles, Christos; Pokki, Juho; Ergeneman, Olgac; Erni, Sandro; Chatzipirpiridis, George; Pané, Salvador; Framme, Carsten; Nelson, Bradley J

    2013-04-23

    To investigate microrobots as an assistive tool for minimally invasive intraocular surgery and to demonstrate mobility and controllability inside the living rabbit eye. A system for wireless magnetic control of untethered microrobots was developed. Mobility and controllability of a microrobot are examined in different media, specifically vitreous, balanced salt solution (BSS), and silicone oil. This is demonstrated through ex vivo and in vivo animal experiments. The developed electromagnetic system enables precise control of magnetic microrobots over a workspace that covers the posterior eye segment. The system allows for rotation and translation of the microrobot in different media (vitreous, BSS, silicone oil) inside the eye. Intravitreal introduction of untethered mobile microrobots can enable sutureless and precise ophthalmic procedures. Ex vivo and in vivo experiments demonstrate that microrobots can be manipulated inside the eye. Potential applications are targeted drug delivery for maculopathies such as AMD, intravenous deployment of anticoagulation agents for retinal vein occlusion (RVO), and mechanical applications, such as manipulation of epiretinal membrane peeling (ERM). The technology has the potential to reduce the invasiveness of ophthalmic surgery and assist in the treatment of a variety of ophthalmic diseases.

  1. A resolution commending EyeCare America for its volunteerism and efforts to preserve eyesight throughout the previous 25 years.

    THOMAS, 111th Congress

    Sen. Nelson, Ben [D-NE

    2010-06-16

    Senate - 06/16/2010 Submitted in the Senate, considered, and agreed to without amendment and with a preamble by Unanimous Consent. (All Actions) Tracker: This bill has the status Agreed to in SenateHere are the steps for Status of Legislation:

  2. Visual Sonority Modulates Infants' Attraction to Sign Language

    ERIC Educational Resources Information Center

    Stone, Adam; Petitto, Laura-Ann; Bosworth, Rain

    2018-01-01

    The infant brain may be predisposed to identify perceptually salient cues that are common to both signed and spoken languages. Recent theory based on spoken languages has advanced sonority as one of these potential language acquisition cues. Using a preferential looking paradigm with an infrared eye tracker, we explored visual attention of hearing…

  3. Development of a model performance-based sign sheeting specification based on the evaluation of nighttime traffic signs using legibility and eye-tracker data.

    DOT National Transportation Integrated Search

    2010-09-01

    This project focused on the evaluation of traffic sign sheeting performance in terms of meeting the nighttime : driver needs. The goal was to develop a nighttime driver needs specification for traffic signs. The : researchers used nighttime sign legi...

  4. Senior Transportation and Mobility Improvement Act of 2011

    THOMAS, 112th Congress

    Sen. Kohl, Herb [D-WI

    2011-12-05

    Senate - 12/05/2011 Read twice and referred to the Committee on Banking, Housing, and Urban Affairs. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  5. Interacting with mobile devices by fusion eye and hand gestures recognition systems based on decision tree approach

    NASA Astrophysics Data System (ADS)

    Elleuch, Hanene; Wali, Ali; Samet, Anis; Alimi, Adel M.

    2017-03-01

    Two systems of eyes and hand gestures recognition are used to control mobile devices. Based on a real-time video streaming captured from the device's camera, the first system recognizes the motion of user's eyes and the second one detects the static hand gestures. To avoid any confusion between natural and intentional movements we developed a system to fuse the decision coming from eyes and hands gesture recognition systems. The phase of fusion was based on decision tree approach. We conducted a study on 5 volunteers and the results that our system is robust and competitive.

  6. EYE MOVEMENT RECORDING AND NONLINEAR DYNAMICS ANALYSIS – THE CASE OF SACCADES#

    PubMed Central

    Aştefănoaei, Corina; Pretegiani, Elena; Optican, L.M.; Creangă, Dorina; Rufa, Alessandra

    2015-01-01

    Evidence of a chaotic behavioral trend in eye movement dynamics was examined in the case of a saccadic temporal series collected from a healthy human subject. Saccades are highvelocity eye movements of very short duration, their recording being relatively accessible, so that the resulting data series could be studied computationally for understanding the neural processing in a motor system. The aim of this study was to assess the complexity degree in the eye movement dynamics. To do this we analyzed the saccadic temporal series recorded with an infrared camera eye tracker from a healthy human subject in a special experimental arrangement which provides continuous records of eye position, both saccades (eye shifting movements) and fixations (focusing over regions of interest, with rapid, small fluctuations). The semi-quantitative approach used in this paper in studying the eye functioning from the viewpoint of non-linear dynamics was accomplished by some computational tests (power spectrum, portrait in the state space and its fractal dimension, Hurst exponent and largest Lyapunov exponent) derived from chaos theory. A high complexity dynamical trend was found. Lyapunov largest exponent test suggested bi-stability of cellular membrane resting potential during saccadic experiment. PMID:25698889

  7. Super-resolution optics for virtual reality

    NASA Astrophysics Data System (ADS)

    Grabovičkić, Dejan; Benitez, Pablo; Miñano, Juan C.; Zamora, Pablo; Buljan, Marina; Narasimhan, Bharathwaj; Nikolic, Milena I.; Lopez, Jesus; Gorospe, Jorge; Sanchez, Eduardo; Lastres, Carmen; Mohedano, Ruben

    2017-06-01

    In present commercial Virtual Reality (VR) headsets the resolution perceived is still limited, since the VR pixel density (typically 10-15 pixels/deg) is well below what the human eye can resolve (60 pixels/deg). We present here novel advanced optical design approaches that dramatically increase the perceived resolution of the VR keeping the large FoV required in VR applications. This approach can be applied to a vast number of optical architectures, including some advanced configurations, as multichannel designs. All this is done at the optical design stage, and no eye tracker is needed in the headset.

  8. Mobile Eye Tracking Reveals Little Evidence for Age Differences in Attentional Selection for Mood Regulation

    PubMed Central

    Isaacowitz, Derek M.; Livingstone, Kimberly M.; Harris, Julia A.; Marcotte, Stacy L.

    2014-01-01

    We report two studies representing the first use of mobile eye tracking to study emotion regulation across adulthood. Past research on age differences in attentional deployment using stationary eye tracking has found older adults show relatively more positive looking, and seem to benefit more mood-wise from this looking pattern, compared to younger adults. However, these past studies have greatly constrained the stimuli participants can look at, despite real-world settings providing numerous possibilities for what to choose to look at. We therefore used mobile eye tracking to study age differences in attentional selection, as indicated by fixation patterns to stimuli of different valence freely chosen by the participant. In contrast to stationary eye tracking studies of attentional deployment, Study 1 showed that younger and older individuals generally selected similar proportions of valenced stimuli, and attentional selection had similar effects on mood across age groups. Study 2 replicated this pattern with an adult lifespan sample including middle-aged individuals. Emotion regulation-relevant attention may thus differ depending on whether stimuli are freely chosen or not. PMID:25527965

  9. Hand-Eye Calibration in Visually-Guided Robot Grinding.

    PubMed

    Li, Wen-Long; Xie, He; Zhang, Gang; Yan, Si-Jie; Yin, Zhou-Ping

    2016-11-01

    Visually-guided robot grinding is a novel and promising automation technique for blade manufacturing. One common problem encountered in robot grinding is hand-eye calibration, which establishes the pose relationship between the end effector (hand) and the scanning sensor (eye). This paper proposes a new calibration approach for robot belt grinding. The main contribution of this paper is its consideration of both joint parameter errors and pose parameter errors in a hand-eye calibration equation. The objective function of the hand-eye calibration is built and solved, from which 30 compensated values (corresponding to 24 joint parameters and six pose parameters) are easily calculated in a closed solution. The proposed approach is economic and simple because only a criterion sphere is used to calculate the calibration parameters, avoiding the need for an expensive and complicated tracking process using a laser tracker. The effectiveness of this method is verified using a calibration experiment and a blade grinding experiment. The code used in this approach is attached in the Appendix.

  10. Eye gaze correction with stereovision for video-teleconferencing.

    PubMed

    Yang, Ruigang; Zhang, Zhengyou

    2004-07-01

    The lack of eye contact in desktop video teleconferencing substantially reduces the effectiveness of video contents. While expensive and bulky hardware is available on the market to correct eye gaze, researchers have been trying to provide a practical software-based solution to bring video-teleconferencing one step closer to the mass market. This paper presents a novel approach: Based on stereo analysis combined with rich domain knowledge (a personalized face model), we synthesize, using graphics hardware, a virtual video that maintains eye contact. A 3D stereo head tracker with a personalized face model is used to compute initial correspondences across two views. More correspondences are then added through template and feature matching. Finally, all the correspondence information is fused together for view synthesis using view morphing techniques. The combined methods greatly enhance the accuracy and robustness of the synthesized views. Our current system is able to generate an eye-gaze corrected video stream at five frames per second on a commodity 1 GHz PC.

  11. Driving experience and special skills reflected in eye movements

    NASA Astrophysics Data System (ADS)

    Paeglis, Roberts; Bluss, Kristaps; Atvars, Aigars

    2011-10-01

    When driving a vehicle, people use the central vision both to plan ahead and monitor their performance feedback (research by Donges, 1978 [1], and after). Discussion is ongoing if making eye movements do more than gathering information. Moving eyes may also prepare the following body movements like steering. Different paradigms exist to explore vision in driving. Our perspective was to quantify eye movements and fixation patterns of different proficiency individuals, a driving learner, a novice, an experienced driver and a European level car racer. Thus for safety reasons we started by asking them to follow a video tour through a known city, remote from an infrared eye tracker sampling at 250 Hz. We report that gaze strategy of an experienced driver differs qualitatively from that of an automobile sports master. Quantitative differences only were found between the latter and a driving learner or a novice driver. Experience in a motor action provides skills different from sports training. We are aiming at testing this finding in real world driving.

  12. Mobile Workforce State Income Tax Simplification Act of 2012

    THOMAS, 112th Congress

    Rep. Coble, Howard [R-NC-6

    2011-05-12

    Senate - 05/16/2012 Received in the Senate and Read twice and referred to the Committee on Finance. (All Actions) Tracker: This bill has the status Passed HouseHere are the steps for Status of Legislation:

  13. To require the Forest Service to accommodate, to the extent consistent with the management objectives and limitations applicable to the National Forest System lands at issue, individuals with mobility disabilities who need to use a power-driven mobility device for reasonable access to such lands.

    THOMAS, 111th Congress

    Rep. Alexander, Rodney [R-LA-5

    2009-12-08

    House - 03/29/2010 Referred to the Subcommittee on Department Operations, Oversight, Nutrition and Forestry. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  14. Relationship between abstract thinking and eye gaze pattern in patients with schizophrenia

    PubMed Central

    2014-01-01

    Background Effective integration of visual information is necessary to utilize abstract thinking, but patients with schizophrenia have slow eye movement and usually explore limited visual information. This study examines the relationship between abstract thinking ability and the pattern of eye gaze in patients with schizophrenia using a novel theme identification task. Methods Twenty patients with schizophrenia and 22 healthy controls completed the theme identification task, in which subjects selected which word, out of a set of provided words, best described the theme of a picture. Eye gaze while performing the task was recorded by the eye tracker. Results Patients exhibited a significantly lower correct rate for theme identification and lesser fixation and saccade counts than controls. The correct rate was significantly correlated with the fixation count in patients, but not in controls. Conclusions Patients with schizophrenia showed impaired abstract thinking and decreased quality of gaze, which were positively associated with each other. Theme identification and eye gaze appear to be useful as tools for the objective measurement of abstract thinking in patients with schizophrenia. PMID:24739356

  15. AH-64D Apache Longbow Aircrew Workload Assessment for Unmanned Aerial System (UAS) Employment

    DTIC Science & Technology

    2009-01-01

    data sources, gathering and maintaining the data needed, and completing and reviewing the collection information. Send comments regarding this burden...a head-eye tracker), audio-video, and tactics, techniques and procedures data were collected and analyzed. Pilot workload was found to be...5 2. Method 6 2.1 Data Collection

  16. Three-Month-Olds' Visual Preference for Faces and Its Underlying Visual Processing Mechanisms

    ERIC Educational Resources Information Center

    Turati, C.; Valenza, E.; Leo, I.; Simion, F.

    2005-01-01

    This study was aimed at investigating the face preference phenomenon and its underlying mechanisms at 3 months of age. Using an eye-tracker apparatus, Experiment 1 demonstrated that 3-month-olds prefer natural face images to unnatural ones, replicating and extending previous evidence obtained with schematic facelike stimuli. Experiments 2 and 3…

  17. Development of a model performance-based sign sheeting specification based on the evaluation of nighttime traffic signs using legibility and eye-tracker data : data and analyses.

    DOT National Transportation Integrated Search

    2010-09-01

    This report presents data and technical analyses for Texas Department of Transportation Project 0-5235. This : project focused on the evaluation of traffic sign sheeting performance in terms of meeting the nighttime : driver needs. The goal was to de...

  18. Automated Gaze-Contingent Objects Elicit Orientation Following in 8-Month-Old Infants

    ERIC Educational Resources Information Center

    Deligianni, Fani; Senju, Atsushi; Gergely, Gyorgy; Csibra, Gergely

    2011-01-01

    The current study tested whether the purely amodal cue of contingency elicits orientation following behavior in 8-month-old infants. We presented 8-month-old infants with automated objects without human features that did or did not react contingently to the infants' fixations recorded by an eye tracker. We found that an object's occasional…

  19. Accurate or Assumed: Visual Learning in Children with ASD

    ERIC Educational Resources Information Center

    Trembath, David; Vivanti, Giacomo; Iacono, Teresa; Dissanayake, Cheryl

    2015-01-01

    Children with autism spectrum disorder (ASD) are often described as visual learners. We tested this assumption in an experiment in which 25 children with ASD, 19 children with global developmental delay (GDD), and 17 typically developing (TD) children were presented a series of videos via an eye tracker in which an actor instructed them to…

  20. Accurate Memory for Object Location by Individuals with Intellectual Disability: Absolute Spatial Tagging Instead of Configural Processing?

    ERIC Educational Resources Information Center

    Giuliani, Fabienne; Favrod, Jerome; Grasset, Francois; Schenk, Francoise

    2011-01-01

    Using head-mounted eye tracker material, we assessed spatial recognition abilities (e.g., reaction to object permutation, removal or replacement with a new object) in participants with intellectual disabilities. The "Intellectual Disabilities (ID)" group (n = 40) obtained a score totalling a 93.7% success rate, whereas the "Normal Control" group…

  1. Attention to the Mouth and Gaze Following in Infancy Predict Language Development

    ERIC Educational Resources Information Center

    Tenenbaum, Elena J.; Sobel, David M.; Sheinkpof, Stephen J.; Malle, Bertram F.; Morgan, James L.

    2015-01-01

    We investigated longitudinal relations among gaze following and face scanning in infancy and later language development. At 12 months, infants watched videos of a woman describing an object while their passive viewing was measured with an eye-tracker. We examined the relation between infants' face scanning behavior and their tendency to follow the…

  2. Delayed Match Retrieval: A Novel Anticipation-Based Visual Working Memory Paradigm

    ERIC Educational Resources Information Center

    Kaldy, Zsuzsa; Guillory, Sylvia B.; Blaser, Erik

    2016-01-01

    We tested 8- and 10-month-old infants' visual working memory (VWM) for object-location bindings--"what is where"--with a novel paradigm, Delayed Match Retrieval, that measured infants' anticipatory gaze responses (using a Tobii T120 eye tracker). In an inversion of Delayed-Match-to-Sample tasks and with inspiration from the game…

  3. Computer/Mobile Device Screen Time of Children and Their Eye Care Behavior: The Roles of Risk Perception and Parenting.

    PubMed

    Chang, Fong-Ching; Chiu, Chiung-Hui; Chen, Ping-Hung; Miao, Nae-Fang; Chiang, Jeng-Tung; Chuang, Hung-Yi

    2018-03-01

    This study assessed the computer/mobile device screen time and eye care behavior of children and examined the roles of risk perception and parental practices. Data were obtained from a sample of 2,454 child-parent dyads recruited from 30 primary schools in Taipei city and New Taipei city, Taiwan, in 2016. Self-administered questionnaires were collected from students and parents. Fifth-grade students spend more time on new media (computer/smartphone/tablet: 16 hours a week) than on traditional media (television: 10 hours a week). The average daily screen time (3.5 hours) for these children exceeded the American Academy of Pediatrics recommendations (≤2 hours). Multivariate analysis results showed that after controlling for demographic factors, the parents with higher levels of risk perception and parental efficacy were more likely to mediate their child's eye care behavior. Children who reported lower academic performance, who were from non-intact families, reported lower levels of risk perception of mobile device use, had parents who spent more time using computers and mobile devices, and had lower levels of parental mediation were more likely to spend more time using computers and mobile devices; whereas children who reported higher academic performance, higher levels of risk perception, and higher levels of parental mediation were more likely to engage in higher levels of eye care behavior. Risk perception by children and parental practices are associated with the amount of screen time that children regularly engage in and their level of eye care behavior.

  4. Designs and Algorithms to Map Eye Tracking Data with Dynamic Multielement Moving Objects.

    PubMed

    Kang, Ziho; Mandal, Saptarshi; Crutchfield, Jerry; Millan, Angel; McClung, Sarah N

    2016-01-01

    Design concepts and algorithms were developed to address the eye tracking analysis issues that arise when (1) participants interrogate dynamic multielement objects that can overlap on the display and (2) visual angle error of the eye trackers is incapable of providing exact eye fixation coordinates. These issues were addressed by (1) developing dynamic areas of interests (AOIs) in the form of either convex or rectangular shapes to represent the moving and shape-changing multielement objects, (2) introducing the concept of AOI gap tolerance (AGT) that controls the size of the AOIs to address the overlapping and visual angle error issues, and (3) finding a near optimal AGT value. The approach was tested in the context of air traffic control (ATC) operations where air traffic controller specialists (ATCSs) interrogated multiple moving aircraft on a radar display to detect and control the aircraft for the purpose of maintaining safe and expeditious air transportation. In addition, we show how eye tracking analysis results can differ based on how we define dynamic AOIs to determine eye fixations on moving objects. The results serve as a framework to more accurately analyze eye tracking data and to better support the analysis of human performance.

  5. Designs and Algorithms to Map Eye Tracking Data with Dynamic Multielement Moving Objects

    PubMed Central

    Mandal, Saptarshi

    2016-01-01

    Design concepts and algorithms were developed to address the eye tracking analysis issues that arise when (1) participants interrogate dynamic multielement objects that can overlap on the display and (2) visual angle error of the eye trackers is incapable of providing exact eye fixation coordinates. These issues were addressed by (1) developing dynamic areas of interests (AOIs) in the form of either convex or rectangular shapes to represent the moving and shape-changing multielement objects, (2) introducing the concept of AOI gap tolerance (AGT) that controls the size of the AOIs to address the overlapping and visual angle error issues, and (3) finding a near optimal AGT value. The approach was tested in the context of air traffic control (ATC) operations where air traffic controller specialists (ATCSs) interrogated multiple moving aircraft on a radar display to detect and control the aircraft for the purpose of maintaining safe and expeditious air transportation. In addition, we show how eye tracking analysis results can differ based on how we define dynamic AOIs to determine eye fixations on moving objects. The results serve as a framework to more accurately analyze eye tracking data and to better support the analysis of human performance. PMID:27725830

  6. Asynchronous timing and Doppler recovery in DSP based DPSK modems for fixed and mobile satellite applications

    NASA Astrophysics Data System (ADS)

    Koblents, B.; Belanger, M.; Woods, D.; McLane, P. J.

    While conventional analog modems employ some kind of clock wave regenerator circuit for synchronous timing recovery, in sampled modem receivers the timing is recovered asynchronously to the incoming data stream, with no adjustment being made to the input sampling rate. All timing corrections are accomplished by digital operations on the sampled data stream, and timing recovery is asynchronous with the uncontrolled, input A/D system. A good timing error measurement algorithm is a zero crossing tracker proposed by Gardner. Digital, speech rate (2400 - 4800 bps) M-PSK modem receivers employing Gardner's zero crossing tracker were implemented and tested and found to achieve BER performance very close to theoretical values on the AWGN channel. Nyguist pulse shaped modem systems with excess bandwidth factors ranging from 100 to 60 percent were considered. We can show that for any symmetric M-PSK signal set Gardner's NDA algorithm is free of pattern jitter for any carrier phase offset for rectangular pulses and for Nyquist pulses having 100 percent excess bandwidth. Also, the Nyquist pulse shaped system is studied on the mobile satellite channel, where Doppler shifts and multipath fading degrade the pi/4-DQPSK signal. Two simple modifications to Gardner's zero crossing tracker enable it to remain useful in the presence of multipath fading.

  7. Asynchronous timing and Doppler recovery in DSP based DPSK modems for fixed and mobile satellite applications

    NASA Technical Reports Server (NTRS)

    Koblents, B.; Belanger, M.; Woods, D.; Mclane, P. J.

    1993-01-01

    While conventional analog modems employ some kind of clock wave regenerator circuit for synchronous timing recovery, in sampled modem receivers the timing is recovered asynchronously to the incoming data stream, with no adjustment being made to the input sampling rate. All timing corrections are accomplished by digital operations on the sampled data stream, and timing recovery is asynchronous with the uncontrolled, input A/D system. A good timing error measurement algorithm is a zero crossing tracker proposed by Gardner. Digital, speech rate (2400 - 4800 bps) M-PSK modem receivers employing Gardner's zero crossing tracker were implemented and tested and found to achieve BER performance very close to theoretical values on the AWGN channel. Nyguist pulse shaped modem systems with excess bandwidth factors ranging from 100 to 60 percent were considered. We can show that for any symmetric M-PSK signal set Gardner's NDA algorithm is free of pattern jitter for any carrier phase offset for rectangular pulses and for Nyquist pulses having 100 percent excess bandwidth. Also, the Nyquist pulse shaped system is studied on the mobile satellite channel, where Doppler shifts and multipath fading degrade the pi/4-DQPSK signal. Two simple modifications to Gardner's zero crossing tracker enable it to remain useful in the presence of multipath fading.

  8. Mobile Apps for Eye Care in Canada: An Analysis of the iTunes Store.

    PubMed

    Rodin, Alexander; Shachak, Aviv; Miller, Aaron; Akopyan, Vladimir; Semenova, Nataliya

    2017-06-14

    Mobile phone screens can facilitate stimulation to various components of the visual system and many mobile apps are accepted as a means of providing clinical assessments for the oculo-visual system. Although many of these apps are intended for use in clinical settings, there is a growing number of apps in eye care developed for self-tests and eye exercises for lay people. These and other features, however, have not yet been well described. Our objective was to identify, describe, and categorize mobile apps related to eye care that are available to users in the Canadian iTunes market. We conducted an extensive search of the Apple iTunes Store for apps related to eye care. We used the terms "eye," "eye care," "vision," and "eye test" and included apps that are targeted at both lay people and medical professionals. We excluded apps whose primary function is not related to eye care. Eligible apps were categorized by primary purpose, based on how they were described by their developers in the iTunes Store. Our search yielded 10,657 apps, of which 427 met our inclusion criteria. After removing duplicates, 355 unique apps were subject to further review. We assigned the eligible apps to three distinct categories: 39/355 apps (11.0%) were intended for use by medical professionals, 236 apps (66.5%, 236/355) were intended for use by lay people, and 80 apps (22.5%, 80/355) were intended for marketing eye care and eye-care products. We identified 9 subcategories of apps based on the descriptions of their primary functions. Apps for medical professionals fell into three subcategories: clinical calculators (n=6), clinical diagnostic tools (n=18), and education and networking apps for professionals (n=15). Apps for lay people fell into four subcategories: self-testing (n=153), eye exercises (n=30), patient tools and low vision aids (n=35), and apps for patient education (n=18). Mixed-use apps (n=80) were placed into two subcategories: marketing of individual practitioners or eye-care products (n=72) and marketing of multiple eye-care products or professional services. The most extensive subcategory pertaining to eye care consisted of apps for use by lay people, especially for conducting self-tests (n=236). This study revealed a previously uncharacterized category of apps intended for use by doctors and patients, of which the primary goal is marketing of eye-care services and products (n=80). ©Alexander Rodin, Aviv Shachak, Aaron Miller, Vladimir Akopyan, Nataliya Semenova. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 14.06.2017.

  9. Biometric recognition via texture features of eye movement trajectories in a visual searching task.

    PubMed

    Li, Chunyong; Xue, Jiguo; Quan, Cheng; Yue, Jingwei; Zhang, Chenggang

    2018-01-01

    Biometric recognition technology based on eye-movement dynamics has been in development for more than ten years. Different visual tasks, feature extraction and feature recognition methods are proposed to improve the performance of eye movement biometric system. However, the correct identification and verification rates, especially in long-term experiments, as well as the effects of visual tasks and eye trackers' temporal and spatial resolution are still the foremost considerations in eye movement biometrics. With a focus on these issues, we proposed a new visual searching task for eye movement data collection and a new class of eye movement features for biometric recognition. In order to demonstrate the improvement of this visual searching task being used in eye movement biometrics, three other eye movement feature extraction methods were also tested on our eye movement datasets. Compared with the original results, all three methods yielded better results as expected. In addition, the biometric performance of these four feature extraction methods was also compared using the equal error rate (EER) and Rank-1 identification rate (Rank-1 IR), and the texture features introduced in this paper were ultimately shown to offer some advantages with regard to long-term stability and robustness over time and spatial precision. Finally, the results of different combinations of these methods with a score-level fusion method indicated that multi-biometric methods perform better in most cases.

  10. Dual System for Enhancing Cognitive Abilities of Children with ADHD Using Leap Motion and eye-Tracking Technologies.

    PubMed

    Garcia-Zapirain, Begoña; de la Torre Díez, Isabel; López-Coronado, Miguel

    2017-07-01

    Attention Deficit Hyperactivity Disorder (ADHD) is a brain disorder marked by an ongoing pattern of inattention and/or hyperactivity-impulsivity that affects with development or functioning. It affects 3-5% of all American and European children. The objective of this paper is to develop and test a dual system for the rehabilitation of cognitive functions in children with ADHD. A technological platform has been developed using the ". NET framework", which makes use of two physiological sensors, -an eye-tracker and a hand gesture recognition sensor- in order to provide children with the opportunity to develop their learning and attention skills. The two physiological sensors we utilized for the development are the Tobii X1 Light Eye Tracker and the Leap Motion. SUS and QUIS questionnaires have been carried out. 19 users tested the system and the average age was 10.88 years (SD = 3.14). The results obtained after tests were performed were quite positive and hopeful. The learning of the users caused by the system and the interfaces item got a high punctuation with a mean of 7.34 (SD = 1.06) for SUS questionnaire and 7.73 (SD = 0.6) for QUIS questionnaire. We didn't find differences between boys and girls. The developed multimodal rehabilitation system can help to children with attention deficit and learning issues. Moreover, the teachers may utilize this system to track the progression of their students and see their behavior.

  11. [Assessment of laparoscopic training based on eye tracker and electroencephalograph].

    PubMed

    Liu, Yun; Wang, Shuyi; Zhang, Yangun; Xu, Mingzhe; Ye, Shasha; Wang, Peng

    2017-02-01

    The aim of this study is to evaluate the effect of laparoscopic simulation training with different attention. Attention was appraised using the sample entropy and θ/β value, which were calculated according to electroencephalograph(EEG) signal collected with Brain Link. The effect of laparoscopic simulation training was evaluated using the completion time, error number and fixation number, which were calculated according to eye movement signal collected with Tobii eye tracker. Twenty volunteers were recruited in this study. Those with the sample entropy lower than0.77 were classified into group A and those higher than 0.77 into group B. The results showed that the sample entropy of group A was lower than that of group B, and fluctuations of A were more steady. However, the sample entropy of group B showed steady fluctuations in the first five trainings, and then demonstrated relatively dramatic fluctuates in the later five trainings. Compared with that of group B, the θ/β value of group A was smaller and shows steady fluctuations. Group A has a shorter completion time, less errors and faster decrease of fixation number. Therefore, this study reached the following conclusion that the attention of the trainees would affect the training effect. Members in group A, who had a higher attention were more efficient and faster training. For those in group B, although their training skills have been improved, they needed a longer time to reach a plateau.

  12. Usability Testing the "Personal Patient Profile-Prostate" in a Sample of African American and Hispanic Men.

    PubMed

    Wolpin, Seth; Halpenny, Barbara; Sorrentino, Erica; Stewart, Mark; McReynolds, Justin; Cvitkovic, Ivan; Chang, Peter; Berry, Donna

    2016-07-01

    Shared treatment decision making in a cancer setting requires a patient's understanding of the potential benefits and risks of each treatment option. Graphical display of risk information is one approach to improving understanding. Little is known about how patients engage with infographics in the context of health education materials and whether interactions vary with health literacy levels. We conducted an observational study, using an eye tracker device, of how men with newly diagnosed localized prostate cancer visually engaged with an on-screen infographic depicting risk information in the Personal Patient Profile-Prostate. Health literacy was measured with the Short Assessment of Health Literacy-English. Gaze patterns on an exemplar screens containing infographics about survival were analyzed and explored with respect to sociodemographic and health literacy data. Acceptability of Personal Patient Profile-Prostate was measured with the Acceptability E-scale. Twenty-six English-speaking men participated, and eye tracking data were collected for 12 men on the exemplar page of risk information that we analyzed. We found preliminary evidence of visual scanning and of participants with lower literacy focusing sooner on infographics versus text. Acceptability for Personal Patient Profile-Prostate was high. These findings suggest that infographics may be of higher relative value to participants with low health literacy. Eye trackers may provide valuable information on how people visually engage with infographics and may inform development of health education materials, although care must be taken to minimize data loss.

  13. Direct and indirect effects of attention and visual function on gait impairment in Parkinson's disease: influence of task and turning.

    PubMed

    Stuart, Samuel; Galna, Brook; Delicato, Louise S; Lord, Sue; Rochester, Lynn

    2017-07-01

    Gait impairment is a core feature of Parkinson's disease (PD) which has been linked to cognitive and visual deficits, but interactions between these features are poorly understood. Monitoring saccades allows investigation of real-time cognitive and visual processes and their impact on gait when walking. This study explored: (i) saccade frequency when walking under different attentional manipulations of turning and dual-task; and (ii) direct and indirect relationships between saccades, gait impairment, vision and attention. Saccade frequency (number of fast eye movements per-second) was measured during gait in 60 PD and 40 age-matched control participants using a mobile eye-tracker. Saccade frequency was significantly reduced in PD compared to controls during all conditions. However, saccade frequency increased with a turn and decreased under dual-task for both groups. Poorer attention directly related to saccade frequency, visual function and gait impairment in PD, but not controls. Saccade frequency did not directly relate to gait in PD, but did in controls. Instead, saccade frequency and visual function deficit indirectly impacted gait impairment in PD, which was underpinned by their relationship with attention. In conclusion, our results suggest a vital role for attention with direct and indirect influences on gait impairment in PD. Attention directly impacted saccade frequency, visual function and gait impairment in PD, with connotations for falls. It also underpinned indirect impact of visual and saccadic impairment on gait. Attention therefore represents a key therapeutic target that should be considered in future research. © 2017 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  14. See and be seen: Infant-caregiver social looking during locomotor free play.

    PubMed

    Franchak, John M; Kretch, Kari S; Adolph, Karen E

    2017-10-26

    Face-to-face interaction between infants and their caregivers is a mainstay of developmental research. However, common laboratory paradigms for studying dyadic interaction oversimplify the act of looking at the partner's face by seating infants and caregivers face to face in stationary positions. In less constrained conditions when both partners are freely mobile, infants and caregivers must move their heads and bodies to look at each other. We hypothesized that face looking and mutual gaze for each member of the dyad would decrease with increased motor costs of looking. To test this hypothesis, 12-month-old crawling and walking infants and their parents wore head-mounted eye trackers to record eye movements of each member of the dyad during locomotor free play in a large toy-filled playroom. Findings revealed that increased motor costs decreased face looking and mutual gaze: Each partner looked less at the other's face when their own posture or the other's posture required more motor effort to gain visual access to the other's face. Caregivers mirrored infants' posture by spending more time down on the ground when infants were prone, perhaps to facilitate face looking. Infants looked more at toys than at their caregiver's face, but caregivers looked at their infant's face and at toys in equal amounts. Furthermore, infants looked less at toys and faces compared to studies that used stationary tasks, suggesting that the attentional demands differ in an unconstrained locomotor task. Taken together, findings indicate that ever-changing motor constraints affect real-life social looking. © 2017 John Wiley & Sons Ltd.

  15. Real-time eye tracking for the assessment of driver fatigue.

    PubMed

    Xu, Junli; Min, Jianliang; Hu, Jianfeng

    2018-04-01

    Eye-tracking is an important approach to collect evidence regarding some participants' driving fatigue. In this contribution, the authors present a non-intrusive system for evaluating driver fatigue by tracking eye movement behaviours. A real-time eye-tracker was used to monitor participants' eye state for collecting eye-movement data. These data are useful to get insights into assessing participants' fatigue state during monotonous driving. Ten healthy subjects performed continuous simulated driving for 1-2 h with eye state monitoring on a driving simulator in this study, and these measured features of the fixation time and the pupil area were recorded via using eye movement tracking device. For achieving a good cost-performance ratio and fast computation time, the fuzzy K -nearest neighbour was employed to evaluate and analyse the influence of different participants on the variations in the fixation duration and pupil area of drivers. The findings of this study indicated that there are significant differences in domain value distribution of the pupil area under the condition with normal and fatigue driving state. Result also suggests that the recognition accuracy by jackknife validation reaches to about 89% in average, implying that show a significant potential of real-time applicability of the proposed approach and is capable of detecting driver fatigue.

  16. Real-time eye tracking for the assessment of driver fatigue

    PubMed Central

    Xu, Junli; Min, Jianliang

    2018-01-01

    Eye-tracking is an important approach to collect evidence regarding some participants’ driving fatigue. In this contribution, the authors present a non-intrusive system for evaluating driver fatigue by tracking eye movement behaviours. A real-time eye-tracker was used to monitor participants’ eye state for collecting eye-movement data. These data are useful to get insights into assessing participants’ fatigue state during monotonous driving. Ten healthy subjects performed continuous simulated driving for 1–2 h with eye state monitoring on a driving simulator in this study, and these measured features of the fixation time and the pupil area were recorded via using eye movement tracking device. For achieving a good cost-performance ratio and fast computation time, the fuzzy K-nearest neighbour was employed to evaluate and analyse the influence of different participants on the variations in the fixation duration and pupil area of drivers. The findings of this study indicated that there are significant differences in domain value distribution of the pupil area under the condition with normal and fatigue driving state. Result also suggests that the recognition accuracy by jackknife validation reaches to about 89% in average, implying that show a significant potential of real-time applicability of the proposed approach and is capable of detecting driver fatigue. PMID:29750113

  17. Crawling and walking infants see the world differently

    PubMed Central

    Kretch, Kari S.; Franchak, John M.; Adolph, Karen E.

    2013-01-01

    How does visual experience change over development? To investigate changes in visual input over the developmental transition from crawling to walking, thirty 13-month-olds crawled or walked down a straight path wearing a head-mounted eye-tracker that recorded gaze direction and head-centered field of view. Thirteen additional infants wore a motion-tracker that recorded head orientation. Compared with walkers, crawlers’ field of view contained less walls and more floor. Walkers directed gaze straight ahead at caregivers, whereas crawlers looked down at the floor. Crawlers obtained visual information about targets at higher elevations—caregivers and toys—by craning their heads upward and sitting up to bring the room into view. Findings indicate that visual experiences are intimately tied to infants’ posture. PMID:24341362

  18. A resolution recognizing the 40th anniversary of the National Eye Institute and expressing support for designation of the years 2011 through 2020 as the "Decade of Vision".

    THOMAS, 111th Congress

    Sen. Isakson, Johnny [R-GA

    2009-07-07

    Senate - 07/07/2009 Submitted in the Senate, considered, and agreed to without amendment and with a preamble by Unanimous Consent. (All Actions) Tracker: This bill has the status Agreed to in SenateHere are the steps for Status of Legislation:

  19. MR-eyetracker: a new method for eye movement recording in functional magnetic resonance imaging.

    PubMed

    Kimmig, H; Greenlee, M W; Huethe, F; Mergner, T

    1999-06-01

    We present a method for recording saccadic and pursuit eye movements in the magnetic resonance tomograph designed for visual functional magnetic resonance imaging (fMRI) experiments. To reliably classify brain areas as pursuit or saccade related it is important to carefully measure the actual eye movements. For this purpose, infrared light, created outside the scanner by light-emitting diodes (LEDs), is guided via optic fibers into the head coil and onto the eye of the subject. Two additional fiber optical cables pick up the light reflected by the iris. The illuminating and detecting cables are mounted in a plastic eyepiece that is manually lowered to the level of the eye. By means of differential amplification, we obtain a signal that covaries with the horizontal position of the eye. Calibration of eye position within the scanner yields an estimate of eye position with a resolution of 0.2 degrees at a sampling rate of 1000 Hz. Experiments are presented that employ echoplanar imaging with 12 image planes through visual, parietal and frontal cortex while subjects performed saccadic and pursuit eye movements. The distribution of BOLD (blood oxygen level dependent) responses is shown to depend on the type of eye movement performed. Our method yields high temporal and spatial resolution of the horizontal component of eye movements during fMRI scanning. Since the signal is purely optical, there is no interaction between the eye movement signals and the echoplanar images. This reasonably priced eye tracker can be used to control eye position and monitor eye movements during fMRI.

  20. Construction and Operation of a High-Speed, High-Precision Eye Tracker for Tight Stimulus Synchronization and Real-Time Gaze Monitoring in Human and Animal Subjects.

    PubMed

    Farivar, Reza; Michaud-Landry, Danny

    2016-01-01

    Measurements of the fast and precise movements of the eye-critical to many vision, oculomotor, and animal behavior studies-can be made non-invasively by video oculography. The protocol here describes the construction and operation of a research-grade video oculography system with ~0.1° precision over the full typical viewing range at over 450 Hz with tight synchronization with stimulus onset. The protocol consists of three stages: (1) system assembly, (2) calibration for both cooperative, and for minimally cooperative subjects (e.g., animals or infants), and (3) gaze monitoring and recording.

  1. Individual reactions to stress predict performance during a critical aviation incident.

    PubMed

    Vine, Samuel J; Uiga, Liis; Lavric, Aureliu; Moore, Lee J; Tsaneva-Atanasova, Krasimira; Wilson, Mark R

    2015-01-01

    Understanding the influence of stress on human performance is of theoretical and practical importance. An individual's reaction to stress predicts their subsequent performance; with a "challenge" response to stress leading to better performance than a "threat" response. However, this contention has not been tested in truly stressful environments with highly skilled individuals. Furthermore, the effect of challenge and threat responses on attentional control during visuomotor tasks is poorly understood. Thus, this study aimed to examine individual reactions to stress and their influence on attentional control, among a cohort of commercial pilots performing a stressful flight assessment. Sixteen pilots performed an "engine failure on take-off" scenario, in a high-fidelity flight simulator. Reactions to stress were indexed via self-report; performance was assessed subjectively (flight instructor assessment) and objectively (simulator metrics); gaze behavior data were captured using a mobile eye tracker, and measures of attentional control were subsequently calculated (search rate, stimulus driven attention, and entropy). Hierarchical regression analyses revealed that a threat response was associated with poorer performance and disrupted attentional control. The findings add to previous research showing that individual reactions to stress influence performance and shed light on the processes through which stress influences performance.

  2. Quiet Eye Training Facilitates Competitive Putting Performance in Elite Golfers

    PubMed Central

    Vine, Samuel J.; Moore, Lee J.; Wilson, Mark R.

    2011-01-01

    The aim of this study was to examine the effectiveness of a brief quiet eye (QE) training intervention aimed at optimizing visuomotor control and putting performance of elite golfers under pressure, and in real competition. Twenty-two elite golfers (mean handicap 2.7) recorded putting statistics over 10 rounds of competitive golf before attending training individually. Having been randomly assigned to either a QE training or Control group, participants were fitted with an Applied Science Laboratories Mobile Eye tracker and performed 20 baseline (pre-test) putts from 10 ft. Training consisted of video feedback of their gaze behavior while they completed 20 putts; however the QE-trained group received additional instructions related to maintaining a longer QE period. Participants then recorded their putting statistics over a further 10 competitive rounds and re-visited the laboratory for retention and pressure tests of their visuomotor control and putting performance. Overall, the results were supportive of the efficacy of the QE training intervention. QE duration predicted 43% of the variance in putting performance, underlying its critical role in the visuomotor control of putting. The QE-trained group maintained their optimal QE under pressure conditions, whereas the Control group experienced reductions in QE when anxious, with subsequent effects on performance. Although their performance was similar in the pre-test, the QE-trained group holed more putts and left the ball closer to the hole on missed putts than their Control group counterparts in the pressure test. Importantly, these advantages transferred to the golf course, where QE-trained golfers made 1.9 fewer putts per round, compared to pre-training, whereas the Control group showed no change in their putting statistics. These results reveal that QE training, incorporated into a pre-shot routine, is an effective intervention to help golfers maintain control when anxious. PMID:21713182

  3. Eye pigments in wild-type and eye-color mutant strains of the African malaria vector Anopheles gambiae.

    PubMed

    Beard, C B; Benedict, M Q; Primus, J P; Finnerty, V; Collins, F H

    1995-01-01

    Chromatographic analysis of pigments extracted from wild-type eyes of the mosquito Anopheles gambiae reveals the presence of the ommatin precursor 3-hydroxykynurenine, its transamination derivative xanthurenic acid, and a dark, red-brown pigment spot that probably is composed of two or more low mobility xanthommatins. No colored or fluorescent pteridines are evident. Mosquitoes homozygous for an autosomal recessive mutation at the red-eye (r) locus have a brick-red eye color in larvae, pupae, and young adults, in contrast to the almost black color of the wild eye. Mosquitoes homozygous for this mutant allele have levels of ommochrome precursors that are indistinguishable from the wild-type, but the low-mobility xanthommatin spot is ochre-brown in color rather than red-brown as in the wild-type. Mosquitoes with two different mutant alleles at the X-linked pink-eye locus (p, which confers a pink eye color, and pw, which confers a white eye phenotype in homozygotes or hemizygous males) have normal levels of ommochrome precursors but no detectable xanthommatins. Mosquitoes homozygous for both the r and p mutant alleles have apricot-colored eyes and show no detectable xanthommatins. Both the pink-eye and red-eye mutations appear to involve defects in the transport into or assembly of pigments in the membrane-bound pigment granules rather then defects in ommochrome synthesis.

  4. [Analysis of economic viability of a mobile eye clinic of a referral Ophthalmology Service].

    PubMed

    Lima, Luiz Henrique Soares Gonçalves de; Sousa, Luciene Barbosa de

    2005-01-01

    To analyse the economic viability of a mobile eye clinic of a tertiary referral Ophthalmology Service. The amount of money spent with the purchase and construction of the unit in 2000, and the expenses with its maintenance and operation in 2001 were considered, comparing these expenses with the income obtained from appointments, supplementary tests and eye surgeries through the "Sistema Unico de Saúde" (a health care service provided by the government), in 2001. In order to make an economic analysis, an interest rate of 10% per year and a period of depreciation of 10 years were stipulated. The total amount spent to buy and set up a mobile unit of "Hospital Oftamológico de Sorocaba" was R$ 184,140,00. The amount spent with its maintenance and operation during 2001 was R$ 28,000.00. The unit was used on average during 2 days each week in 2001 and 6492 appointments were made in this period, generating an income of R$ 32,460.00. The appointments generated complementary tests and eye surgeries making up R$ 51,540.00. Therefore, the total amount received directly with the appointments, complementary tests and eye surgeries during 2001 was R$ 84,000.00 paid by the "Sistema Unico de Saúde", according to values established beforehand. Using these values it is possible to make an economic analysis of this enterprise and this was done with and without money savings for depreciation, taking into account the income and the expenses. Besides attending poor communities that are located in distant neighborhoods, a mobile eye clinic can be a source of income for ophthalmologic services.

  5. Waist-up protection for blind individuals using the EyeCane as a primary and secondary mobility aid.

    PubMed

    Buchs, Galit; Simon, Noa; Maidenbaum, Shachar; Amedi, Amir

    2017-01-01

    One of the most stirring statistics in relation to the mobility of blind individuals is the high rate of upper body injuries, even when using the white-cane. We here addressed a rehabilitation- oriented challenge of providing a reliable tool for blind people to avoid waist-up obstacles, namely one of the impediments to their successful mobility using currently available methods (e.g., white-cane). We used the EyeCane, a device we developed which translates distances from several angles to haptic and auditory cues in an intuitive and unobtrusive manner, serving both as a primary and secondary mobility aid. We investigated the rehabilitation potential of such a device in facilitating visionless waist-up body protection. After ∼5 minutes of training with the EyeCane blind participants were able to successfully detect and avoid obstacles waist-high and up. This was significantly higher than their success when using the white-cane alone. As avoidance of obstacles required participants to perform an additional cognitive process after their detection, the avoidance rate was significantly lower than the detection rate. Our work has demonstrated that the EyeCane has the potential to extend the sensory world of blind individuals by expanding their currently accessible inputs, and has offered them a new practical rehabilitation tool.

  6. The effect of extended sensory range via the EyeCane sensory substitution device on the characteristics of visionless virtual navigation.

    PubMed

    Maidenbaum, Shachar; Levy-Tzedek, Shelly; Chebat, Daniel Robert; Namer-Furstenberg, Rinat; Amedi, Amir

    2014-01-01

    Mobility training programs for helping the blind navigate through unknown places with a White-Cane significantly improve their mobility. However, what is the effect of new assistive technologies, offering more information to the blind user, on the underlying premises of these programs such as navigation patterns? We developed the virtual-EyeCane, a minimalistic sensory substitution device translating single-point-distance into auditory cues identical to the EyeCane's in the real world. We compared performance in virtual environments when using the virtual-EyeCane, a virtual-White-Cane, no device and visual navigation. We show that the characteristics of virtual-EyeCane navigation differ from navigation with a virtual-White-Cane or no device, and that virtual-EyeCane users complete more levels successfully, taking shorter paths and with less collisions than these groups, and we demonstrate the relative similarity of virtual-EyeCane and visual navigation patterns. This suggests that additional distance information indeed changes navigation patterns from virtual-White-Cane use, and brings them closer to visual navigation.

  7. Head Worn Display System for Equivalent Visual Operations

    NASA Technical Reports Server (NTRS)

    Cupero, Frank; Valimont, Brian; Wise, John; Best. Carl; DeMers, Bob

    2009-01-01

    Head-Worn Displays or so-called, near-to-eye displays have potentially significant advantages in terms of cost, overcoming cockpit space constraints, and for the display of spatially-integrated information. However, many technical issues need to be overcome before these technologies can be successfully introduced into commercial aircraft cockpits. The results of three activities are reported. First, the near-to-eye display design, technological, and human factors issues are described and a literature review is presented. Second, the results of a fixed-base piloted simulation, investigating the impact of near to eye displays on both operational and visual performance is reported. Straight-in approaches were flown in simulated visual and instrument conditions while using either a biocular or a monocular display placed on either the dominant or non-dominant eye. The pilot's flight performance, visual acuity, and ability to detect unsafe conditions on the runway were tested. The data generally supports a monocular design with minimal impact due to eye dominance. Finally, a method for head tracker system latency measurement is developed and used to compare two different devices.

  8. Real-time recording and classification of eye movements in an immersive virtual environment.

    PubMed

    Diaz, Gabriel; Cooper, Joseph; Kit, Dmitry; Hayhoe, Mary

    2013-10-10

    Despite the growing popularity of virtual reality environments, few laboratories are equipped to investigate eye movements within these environments. This primer is intended to reduce the time and effort required to incorporate eye-tracking equipment into a virtual reality environment. We discuss issues related to the initial startup and provide algorithms necessary for basic analysis. Algorithms are provided for the calculation of gaze angle within a virtual world using a monocular eye-tracker in a three-dimensional environment. In addition, we provide algorithms for the calculation of the angular distance between the gaze and a relevant virtual object and for the identification of fixations, saccades, and pursuit eye movements. Finally, we provide tools that temporally synchronize gaze data and the visual stimulus and enable real-time assembly of a video-based record of the experiment using the Quicktime MOV format, available at http://sourceforge.net/p/utdvrlibraries/. This record contains the visual stimulus, the gaze cursor, and associated numerical data and can be used for data exportation, visual inspection, and validation of calculated gaze movements.

  9. Real-time recording and classification of eye movements in an immersive virtual environment

    PubMed Central

    Diaz, Gabriel; Cooper, Joseph; Kit, Dmitry; Hayhoe, Mary

    2013-01-01

    Despite the growing popularity of virtual reality environments, few laboratories are equipped to investigate eye movements within these environments. This primer is intended to reduce the time and effort required to incorporate eye-tracking equipment into a virtual reality environment. We discuss issues related to the initial startup and provide algorithms necessary for basic analysis. Algorithms are provided for the calculation of gaze angle within a virtual world using a monocular eye-tracker in a three-dimensional environment. In addition, we provide algorithms for the calculation of the angular distance between the gaze and a relevant virtual object and for the identification of fixations, saccades, and pursuit eye movements. Finally, we provide tools that temporally synchronize gaze data and the visual stimulus and enable real-time assembly of a video-based record of the experiment using the Quicktime MOV format, available at http://sourceforge.net/p/utdvrlibraries/. This record contains the visual stimulus, the gaze cursor, and associated numerical data and can be used for data exportation, visual inspection, and validation of calculated gaze movements. PMID:24113087

  10. Differential Gaze Patterns on Eyes and Mouth During Audiovisual Speech Segmentation

    PubMed Central

    Lusk, Laina G.; Mitchel, Aaron D.

    2016-01-01

    Speech is inextricably multisensory: both auditory and visual components provide critical information for all aspects of speech processing, including speech segmentation, the visual components of which have been the target of a growing number of studies. In particular, a recent study (Mitchel and Weiss, 2014) established that adults can utilize facial cues (i.e., visual prosody) to identify word boundaries in fluent speech. The current study expanded upon these results, using an eye tracker to identify highly attended facial features of the audiovisual display used in Mitchel and Weiss (2014). Subjects spent the most time watching the eyes and mouth. A significant trend in gaze durations was found with the longest gaze duration on the mouth, followed by the eyes and then the nose. In addition, eye-gaze patterns changed across familiarization as subjects learned the word boundaries, showing decreased attention to the mouth in later blocks while attention on other facial features remained consistent. These findings highlight the importance of the visual component of speech processing and suggest that the mouth may play a critical role in visual speech segmentation. PMID:26869959

  11. Eye gaze tracking based on the shape of pupil image

    NASA Astrophysics Data System (ADS)

    Wang, Rui; Qiu, Jian; Luo, Kaiqing; Peng, Li; Han, Peng

    2018-01-01

    Eye tracker is an important instrument for research in psychology, widely used in attention, visual perception, reading and other fields of research. Because of its potential function in human-computer interaction, the eye gaze tracking has already been a topic of research in many fields over the last decades. Nowadays, with the development of technology, non-intrusive methods are more and more welcomed. In this paper, we will present a method based on the shape of pupil image to estimate the gaze point of human eyes without any other intrusive devices such as a hat, a pair of glasses and so on. After using the ellipse fitting algorithm to deal with the pupil image we get, we can determine the direction of the fixation by the shape of the pupil.The innovative aspect of this method is to utilize the new idea of the shape of the pupil so that we can avoid much complicated algorithm. The performance proposed is very helpful for the study of eye gaze tracking, which just needs one camera without infrared light to know the changes in the shape of the pupil to determine the direction of the eye gazing, no additional condition is required.

  12. Feasibility of utilizing a commercial eye tracker to assess electronic health record use during patient simulation.

    PubMed

    Gold, Jeffrey Allen; Stephenson, Laurel E; Gorsuch, Adriel; Parthasarathy, Keshav; Mohan, Vishnu

    2016-09-01

    Numerous reports describe unintended consequences of electronic health record implementation. Having previously described physicians' failures to recognize patient safety issues within our electronic health record simulation environment, we now report on our use of eye and screen-tracking technology to understand factors associated with poor error recognition during an intensive care unit-based electronic health record simulation. We linked performance on the simulation to standard eye and screen-tracking readouts including number of fixations, saccades, mouse clicks and screens visited. In addition, we developed an overall Composite Eye Tracking score which measured when, where and how often each safety item was viewed. For 39 participants, the Composite Eye Tracking score correlated with performance on the simulation (p = 0.004). Overall, the improved performance was associated with a pattern of rapid scanning of data manifested by increased number of screens visited (p = 0.001), mouse clicks (p = 0.03) and saccades (p = 0.004). Eye tracking can be successfully integrated into electronic health record-based simulation and provides a surrogate measure of cognitive decision making and electronic health record usability. © The Author(s) 2015.

  13. Using Eye Tracking to Explore Consumers' Visual Behavior According to Their Shopping Motivation in Mobile Environments.

    PubMed

    Hwang, Yoon Min; Lee, Kun Chang

    2017-07-01

    Despite a strong shift to mobile shopping trends, many in-depth questions about mobile shoppers' visual behaviors in mobile shopping environments remain unaddressed. This study aims to answer two challenging research questions (RQs): (a) how much does shopping motivation like goal orientation and recreation influence mobile shoppers' visual behavior toward displays of shopping information on a mobile shopping screen and (b) how much of mobile shoppers' visual behavior influences their purchase intention for the products displayed on a mobile shopping screen? An eye-tracking approach is adopted to answer the RQs empirically. The experimental results showed that goal-oriented shoppers paid closer attention to products' information areas to meet their shopping goals. Their purchase intention was positively influenced by their visual attention to the two areas of interest such as product information and consumer opinions. In contrast, recreational shoppers tended to visually fixate on the promotion area, which positively influences their purchase intention. The results contribute to understanding mobile shoppers' visual behaviors and shopping intentions from the perspective of mindset theory.

  14. An evaluation of eye tracking technology in the assessment of 12 lead electrocardiography interpretation.

    PubMed

    Breen, Cathal J; Bond, Raymond; Finlay, Dewar

    2014-01-01

    This study investigated eye tracking technology for 12 lead electrocardiography interpretation to Healthcare Scientist students. Participants (n=33) interpreted ten 12 lead ECG recordings and randomized to receive objective individual appraisal on their efforts either by traditional didactic format or by eye tracker software. One hundred percent of participants reported the experience positively at improving their ECG interpretation competency. ECG analysis time ranged between 13.2 and 59.5s. The rhythm strip was the most common lead studied and fixated on for the longest duration (mean 9.9s). Lead I was studied for the shortest duration (mean 0.25s). Feedback using eye tracking data during ECG interpretation did not produce any significant variation between the assessment marks of the study and the control groups (p=0.32). Although the hypothesis of this study was rejected active teaching and early feedback practices are recommended within this discipline. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. GPS as a tool used in tourism as illustrated by selected mobile applications

    NASA Astrophysics Data System (ADS)

    Szark-Eckardt, Mirosława

    2017-11-01

    Mobile technologies have permanently changed our way of life. Their availability, common use and introducing to virtually all areas of human activity means that we can call present times the age of mobility [1]. Mobile applications based on the GPS module belong to the most dynamically developing apps as particularly reflected in tourism. A multitude of applications dedicated to different participants of tourism, which can be operated by means of smartphones or simple GPS trackers, are encouraging more people to reach for this kind of technology perceiving it as a basic tool used in today's tourism. Due to an increasingly wider access to mobile applications, not only more dynamic development of tourism itself can be noticed, but also the growth of healthy behaviours that comprise a positive "side effect" of tourism based on mobile technology. This article demonstrates a correlation between health and physical condition of the population and the use of mobile applications.

  16. Heads up and camera down: a vision-based tracking modality for mobile mixed reality.

    PubMed

    DiVerdi, Stephen; Höllerer, Tobias

    2008-01-01

    Anywhere Augmentation pursues the goal of lowering the initial investment of time and money necessary to participate in mixed reality work, bridging the gap between researchers in the field and regular computer users. Our paper contributes to this goal by introducing the GroundCam, a cheap tracking modality with no significant setup necessary. By itself, the GroundCam provides high frequency, high resolution relative position information similar to an inertial navigation system, but with significantly less drift. We present the design and implementation of the GroundCam, analyze the impact of several design and run-time factors on tracking accuracy, and consider the implications of extending our GroundCam to different hardware configurations. Motivated by the performance analysis, we developed a hybrid tracker that couples the GroundCam with a wide area tracking modality via a complementary Kalman filter, resulting in a powerful base for indoor and outdoor mobile mixed reality work. To conclude, the performance of the hybrid tracker and its utility within mixed reality applications is discussed.

  17. Formation tracker design of multiple mobile robots with wheel perturbations: adaptive output-feedback approach

    NASA Astrophysics Data System (ADS)

    Yoo, Sung Jin

    2016-11-01

    This paper presents a theoretical design approach for output-feedback formation tracking of multiple mobile robots under wheel perturbations. It is assumed that these perturbations are unknown and the linear and angular velocities of the robots are unmeasurable. First, adaptive state observers for estimating unmeasurable velocities of the robots are developed under the robots' kinematics and dynamics including wheel perturbation effects. Then, we derive a virtual-structure-based formation tracker scheme according to the observer dynamic surface design procedure. The main difficulty of the output-feedback control design is to manage the coupling problems between unmeasurable velocities and unknown wheel perturbation effects. These problems are avoided by using the adaptive technique and the function approximation property based on fuzzy logic systems. From the Lyapunov stability analysis, it is shown that point tracking errors of each robot and synchronisation errors for the desired formation converge to an adjustable neighbourhood of the origin, while all signals in the controlled closed-loop system are semiglobally uniformly ultimately bounded.

  18. Participatory Sensing Marine Debris: Current Trends and Future Opportunities

    NASA Astrophysics Data System (ADS)

    Jambeck, J.; Johnsen, K.

    2016-02-01

    The monitoring of litter and debris is challenging at the global scale because of spatial and temporal variability, disconnected local organizations and the use of paper and pen for documentation. The Marine Debris Tracker mobile app and citizen science program allows for the collection of global standardized data at a scale, speed and efficiency that was not previously possible. The app itself also serves as an outreach and education tool, creating an engaged participatory sensing instrument. This instrument is characterized by several aspects including range and frequency, accuracy and precision, accessibility, measurement dimensions, participant performance, and statistical analysis. Also, important to Marine Debris Tracker is open data and transparency. A web portal provides data that users have logged allowing immediate feedback to users and additional education opportunities. The engagement of users through a top tracker competition and social media keeps participants interested in the Marine Debris Tracker community. Over half a million items have been tracked globally, and maps provide both global and local distribution of data. The Marine Debris Tracker community and dataset continues to grow daily. We will present current usage and engagement, participatory sensing data distributions, choropleth maps of areas of active tracking, and discuss future technologies and platforms to expand data collection and conduct statistical analysis.

  19. Detection of differential viewing patterns to erotic and non-erotic stimuli using eye-tracking methodology.

    PubMed

    Lykins, Amy D; Meana, Marta; Kambe, Gretchen

    2006-10-01

    As a first step in the investigation of the role of visual attention in the processing of erotic stimuli, eye-tracking methodology was employed to measure eye movements during erotic scene presentation. Because eye-tracking is a novel methodology in sexuality research, we attempted to determine whether the eye-tracker could detect differences (should they exist) in visual attention to erotic and non-erotic scenes. A total of 20 men and 20 women were presented with a series of erotic and non-erotic images and tracked their eye movements during image presentation. Comparisons between erotic and non-erotic image groups showed significant differences on two of three dependent measures of visual attention (number of fixations and total time) in both men and women. As hypothesized, there was a significant Stimulus x Scene Region interaction, indicating that participants visually attended to the body more in the erotic stimuli than in the non-erotic stimuli, as evidenced by a greater number of fixations and longer total time devoted to that region. These findings provide support for the application of eye-tracking methodology as a measure of visual attentional capture in sexuality research. Future applications of this methodology to expand our knowledge of the role of cognition in sexuality are suggested.

  20. Diabetic photographic eye screening using a mobile unit in Tayside, Scotland.

    PubMed

    Ellingford, A

    1992-07-01

    Early detection and hospital referral of patients with diabetic changes (retinopathy) is essential if laser photocoagulation is to be effective. The British Diabetic Association (BDA) have therefore funded several diabetic mobile eye screening units and donated them to areas throughout the country, the aim being to screen patients for diabetic retinopathy in those areas. This article describes the use and findings of such a unit in the Tayside area.

  1. Where Will the Triangle Look for It? Attributing False Beliefs to a Geometric Shape at 17 Months

    ERIC Educational Resources Information Center

    Surian, Luca; Geraci, Alessandra

    2012-01-01

    Prior research on implicit mind-reading skills has focussed on how infants anticipate other persons' actions. This study investigated whether 11- and 17-month-olds spontaneously attribute false beliefs (FB) even to a simple animated geometric shape. Infants were shown a triangle chasing a disk through a tunnel. Using an eye-tracker, we found that…

  2. Seniors Have Eyes, Ears, and Teeth Act

    THOMAS, 113th Congress

    Rep. Grayson, Alan [D-FL-9

    2014-12-11

    House - 12/11/2014 Referred to the Committee on Energy and Commerce, and in addition to the Committee on Ways and Means, for a period to be subsequently determined by the Speaker, in each case for consideration of such provisions as fall within the jurisdiction of the committee... (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  3. Mobile and Wearable Device Features that Matter in Promoting Physical Activity.

    PubMed

    Wang, Julie B; Cataldo, Janine K; Ayala, Guadalupe X; Natarajan, Loki; Cadmus-Bertram, Lisa A; White, Martha M; Madanat, Hala; Nichols, Jeanne F; Pierce, John P

    2016-07-01

    As wearable sensors/devices become increasingly popular to promote physical activity (PA), research is needed to examine how and which components of these devices people use to increase their PA levels. (1) To assess usability and level of engagement with the Fitbit One and daily SMS-based prompts in a 6-week PA intervention, and (2) to examine whether use/ level of engagement with specific intervention components were associated with PA change. Data were analyzed from a randomized controlled trial that compared (1) a wearable sensor/ device (Fitbit One) plus SMS-based PA prompts, and (2) Fitbit One only, among overweight/ obese adults (N = 67). We calculated average scores from Likert-type response items that assessed usability and level of engagement with device features (e.g., tracker, website, mobile app, and SMS-based prompts), and assessed whether such factors were associated with change in steps/day (using Actigraph GT3X+). Participants reported the Fitbit One was easy to use and the tracker helped to be more active. Those who used the Fitbit mobile app (36%) vs. those who did not (64%) had an increase in steps at 6-week follow-up, even after adjusting for previous web/app use: +545 steps/ day ( SE = 265) vs. -28 steps/ day ( SE = 242) ( p = .04). Level of engagement with the Fitbit One, particularly the mobile app, was associated with increased steps. Mobile apps can instantly display summaries of PA performance and could optimize self-regulation to activate change. More research is needed to determine whether such modalities might be cost-effective in future intervention research and practice.

  4. Reliability and validity of ten consumer activity trackers.

    PubMed

    Kooiman, Thea J M; Dontje, Manon L; Sprenger, Siska R; Krijnen, Wim P; van der Schans, Cees P; de Groot, Martijn

    2015-01-01

    Activity trackers can potentially stimulate users to increase their physical activity behavior. The aim of this study was to examine the reliability and validity of ten consumer activity trackers for measuring step count in both laboratory and free-living conditions. Healthy adult volunteers (n = 33) walked twice on a treadmill (4.8 km/h) for 30 min while wearing ten different activity trackers (i.e. Lumoback, Fitbit Flex, Jawbone Up, Nike+ Fuelband SE, Misfit Shine, Withings Pulse, Fitbit Zip, Omron HJ-203, Yamax Digiwalker SW-200 and Moves mobile application). In free-living conditions, 56 volunteers wore the same activity trackers for one working day. Test-retest reliability was analyzed with the Intraclass Correlation Coefficient (ICC). Validity was evaluated by comparing each tracker with the gold standard (Optogait system for laboratory and ActivPAL for free-living conditions), using paired samples t-tests, mean absolute percentage errors, correlations and Bland-Altman plots. Test-retest analysis revealed high reliability for most trackers except for the Omron (ICC .14), Moves app (ICC .37) and Nike+ Fuelband (ICC .53). The mean absolute percentage errors of the trackers in laboratory and free-living conditions respectively, were: Lumoback (-0.2, -0.4), Fibit Flex (-5.7, 3.7), Jawbone Up (-1.0, 1.4), Nike+ Fuelband (-18, -24), Misfit Shine (0.2, 1.1), Withings Pulse (-0.5, -7.9), Fitbit Zip (-0.3, 1.2), Omron (2.5, -0.4), Digiwalker (-1.2, -5.9), and Moves app (9.6, -37.6). Bland-Altman plots demonstrated that the limits of agreement varied from 46 steps (Fitbit Zip) to 2422 steps (Nike+ Fuelband) in the laboratory condition, and 866 steps (Fitbit Zip) to 5150 steps (Moves app) in the free-living condition. The reliability and validity of most trackers for measuring step count is good. The Fitbit Zip is the most valid whereas the reliability and validity of the Nike+ Fuelband is low.

  5. Tracking Students' Eye-Movements When Reading Learning Objects on Mobile Phones: A Discourse Analysis of Luganda Language Teacher-Trainees' Reflective Observations

    ERIC Educational Resources Information Center

    Kabugo, David; Muyinda, Paul B.; Masagazi, Fred. M.; Mugagga, Anthony M.; Mulumba, Mathias B.

    2016-01-01

    Although eye-tracking technologies such as Tobii-T120/TX and Eye-Tribe are steadily becoming ubiquitous, and while their appropriation in education can aid teachers to collect robust information on how students move their eyes when reading and engaging with different learning objects, many teachers of Luganda language are yet to gain experiences…

  6. Three-Dimensional Eye Tracking in a Surgical Scenario.

    PubMed

    Bogdanova, Rositsa; Boulanger, Pierre; Zheng, Bin

    2015-10-01

    Eye tracking has been widely used in studying the eye behavior of surgeons in the past decade. Most eye-tracking data are reported in a 2-dimensional (2D) fashion, and data for describing surgeons' behaviors on stereoperception are often missed. With the introduction of stereoscopes in laparoscopic procedures, there is an increasing need for studying the depth perception of surgeons under 3D image-guided surgery. We developed a new algorithm for the computation of convergence points in stereovision by measuring surgeons' interpupillary distance, the distance to the view target, and the difference between gaze locations of the 2 eyes. To test the feasibility of our new algorithm, we recruited 10 individuals to watch stereograms using binocular disparity and asked them to develop stereoperception using a cross-eyed viewing technique. Participants' eye motions were recorded by the Tobii eye tracker while they performed the trials. Convergence points between normal and stereo-viewing conditions were computed using the developed algorithm. All 10 participants were able to develop stereovision after a short period of training. During stereovision, participants' eye convergence points were 14 ± 1 cm in front of their eyes, which was significantly closer than the convergence points under the normal viewing condition (77 ± 20 cm). By applying our method of calculating convergence points using eye tracking, we were able to elicit the eye movement patterns of human operators between the normal and stereovision conditions. Knowledge from this study can be applied to the design of surgical visual systems, with the goal of improving surgical performance and patient safety. © The Author(s) 2015.

  7. Balance, mobility and gaze stability deficits remain following surgical removal of vestibular schwannoma (acoustic neuroma): an observational study.

    PubMed

    Choy, Nancy Low; Johnson, Natalie; Treleaven, Julia; Jull, Gwendolen; Panizza, Benedict; Brown-Rothwell, David

    2006-01-01

    Are there residual deficits in balance, mobility, and gaze stability after surgical removal of vestibular schwannoma? Observational study. Twelve people with a mean age of 52 years who had undergone surgical removal of vestibular schwannoma at least three months previously and had not undergone vestibular rehabilitation. Twelve age- and gender-matched healthy people who acted as controls. Handicap due to dizziness, balance, mobility, and gaze stability was measured. Handicap due to dizziness was moderate for the clinical group. They swayed significantly more than the controls in comfortable stance: firm surface eyes open and visual conflict (p < 0.05); foam surface eyes closed (p < 0.05) and visual conflict (p < 0.05); and feet together: firm surface, eyes closed (p < 0.05), foam surface, eyes open (p < 0.05) and eyes closed (p < 0.01). They displayed a higher rate of failure for timed stance and gaze stability (p < 0.05) than the controls. Step Test (p < 0.01), Tandem Walk Test (p < 0.05) and Dynamic Gait Index (p < 0.01) scores were also significantly reduced compared with controls. There was a significant correlation between handicap due to dizziness and the inability to maintain balance in single limb and tandem stance (r = 0.68, p = 0.02) and the ability to maintain gaze stability during passive head movement (r = 0.78; p = 0.02). A prospective study is required to evaluate vestibular rehabilitation to ameliorate dizziness and to improve balance, mobility, and gaze stability for this clinical group.

  8. Veterinary Medicine Mobility Act of 2013

    THOMAS, 113th Congress

    Sen. Moran, Jerry [R-KS

    2013-05-14

    Senate - 05/14/2013 Read twice and referred to the Committee on the Judiciary. (All Actions) Notes: For further action, see H.R.1528, which became Public Law 113-143 on 8/1/2014. Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  9. Optimal eye movement strategies: a comparison of neurosurgeons gaze patterns when using a surgical microscope.

    PubMed

    Eivazi, Shahram; Hafez, Ahmad; Fuhl, Wolfgang; Afkari, Hoorieh; Kasneci, Enkelejda; Lehecka, Martin; Bednarik, Roman

    2017-06-01

    Previous studies have consistently demonstrated gaze behaviour differences related to expertise during various surgical procedures. In micro-neurosurgery, however, there is a lack of evidence of empirically demonstrated individual differences associated with visual attention. It is unknown exactly how neurosurgeons see a stereoscopic magnified view in the context of micro-neurosurgery and what this implies for medical training. We report on an investigation of the eye movement patterns in micro-neurosurgery using a state-of-the-art eye tracker. We studied the eye movements of nine neurosurgeons while performing cutting and suturing tasks under a surgical microscope. Eye-movement characteristics, such as fixation (focus level) and saccade (visual search pattern), were analysed. The results show a strong relationship between the level of microsurgical skill and the gaze pattern, whereas more expertise is associated with greater eye control, stability, and focusing in eye behaviour. For example, in the cutting task, well-trained surgeons increased their fixation durations on the operating field twice as much as the novices (expert, 848 ms; novice, 402 ms). Maintaining steady visual attention on the target (fixation), as well as being able to quickly make eye jumps from one target to another (saccades) are two important elements for the success of neurosurgery. The captured gaze patterns can be used to improve medical education, as part of an assessment system or in a gaze-training application.

  10. The effect of sampling rate and lowpass filters on saccades - A modeling approach.

    PubMed

    Mack, David J; Belfanti, Sandro; Schwarz, Urs

    2017-12-01

    The study of eye movements has become popular in many fields of science. However, using the preprocessed output of an eye tracker without scrutiny can lead to low-quality or even erroneous data. For example, the sampling rate of the eye tracker influences saccadic peak velocity, while inadequate filters fail to suppress noise or introduce artifacts. Despite previously published guiding values, most filter choices still seem motivated by a trial-and-error approach, and a thorough analysis of filter effects is missing. Therefore, we developed a simple and easy-to-use saccade model that incorporates measured amplitude-velocity main sequences and produces saccades with a similar frequency content to real saccades. We also derived a velocity divergence measure to rate deviations between velocity profiles. In total, we simulated 155 saccades ranging from 0.5° to 60° and subjected them to different sampling rates, noise compositions, and various filter settings. The final goal was to compile a list with the best filter settings for each of these conditions. Replicating previous findings, we observed reduced peak velocities at lower sampling rates. However, this effect was highly non-linear over amplitudes and increasingly stronger for smaller saccades. Interpolating the data to a higher sampling rate significantly reduced this effect. We hope that our model and the velocity divergence measure will be used to provide a quickly accessible ground truth without the need for recording and manually labeling saccades. The comprehensive list of filters allows one to choose the correct filter for analyzing saccade data without resorting to trial-and-error methods.

  11. Evaluation of the Tobii EyeX Eye tracking controller and Matlab toolkit for research.

    PubMed

    Gibaldi, Agostino; Vanegas, Mauricio; Bex, Peter J; Maiello, Guido

    2017-06-01

    The Tobii Eyex Controller is a new low-cost binocular eye tracker marketed for integration in gaming and consumer applications. The manufacturers claim that the system was conceived for natural eye gaze interaction, does not require continuous recalibration, and allows moderate head movements. The Controller is provided with a SDK to foster the development of new eye tracking applications. We review the characteristics of the device for its possible use in scientific research. We develop and evaluate an open source Matlab Toolkit that can be employed to interface with the EyeX device for gaze recording in behavioral experiments. The Toolkit provides calibration procedures tailored to both binocular and monocular experiments, as well as procedures to evaluate other eye tracking devices. The observed performance of the EyeX (i.e. accuracy < 0.6°, precision < 0.25°, latency < 50 ms and sampling frequency ≈55 Hz), is sufficient for some classes of research application. The device can be successfully employed to measure fixation parameters, saccadic, smooth pursuit and vergence eye movements. However, the relatively low sampling rate and moderate precision limit the suitability of the EyeX for monitoring micro-saccadic eye movements or for real-time gaze-contingent stimulus control. For these applications, research grade, high-cost eye tracking technology may still be necessary. Therefore, despite its limitations with respect to high-end devices, the EyeX has the potential to further the dissemination of eye tracking technology to a broad audience, and could be a valuable asset in consumer and gaming applications as well as a subset of basic and clinical research settings.

  12. Vision screening of abused and neglected children by the UCLA Mobile Eye Clinic.

    PubMed

    Yoo, R; Logani, S; Mahat, M; Wheeler, N C; Lee, D A

    1999-07-01

    The purpose of our study was to present descriptive findings of ocular abnormalities in vision screening examinations of abused and neglected children. We compared the prevalence and the nature of eye diseases and refractive error between abused and neglected boys staying at the Hathaway Home, a residential facility for abused children, and boys from neighboring Boys and Girls clubs. The children in the study received vision screening examinations through the UCLA Mobile Eye Clinic following a standard format. Clinical data were analyzed by chi-square test. The children with a history of abuse demonstrated significantly higher prevalence of myopia, astigmatism, and external eye disorders. Our study suggests that children with a history of abuse may be at higher risk for visual impairment. These visual impairments may be the long-term sequelae of child abuse.

  13. Waist-up protection for blind individuals using the EyeCane as a primary and secondary mobility aid

    PubMed Central

    Buchs, Galit; Simon, Noa; Maidenbaum, Shachar; Amedi, Amir

    2017-01-01

    Background: One of the most stirring statistics in relation to the mobility of blind individuals is the high rate of upper body injuries, even when using the white-cane. Objective: We here addressed a rehabilitation- oriented challenge of providing a reliable tool for blind people to avoid waist-up obstacles, namely one of the impediments to their successful mobility using currently available methods (e.g., white-cane). Methods: We used the EyeCane, a device we developed which translates distances from several angles to haptic and auditory cues in an intuitive and unobtrusive manner, serving both as a primary and secondary mobility aid. We investigated the rehabilitation potential of such a device in facilitating visionless waist-up body protection. Results: After ∼5 minutes of training with the EyeCane blind participants were able to successfully detect and avoid obstacles waist-high and up. This was significantly higher than their success when using the white-cane alone. As avoidance of obstacles required participants to perform an additional cognitive process after their detection, the avoidance rate was significantly lower than the detection rate. Conclusion: Our work has demonstrated that the EyeCane has the potential to extend the sensory world of blind individuals by expanding their currently accessible inputs, and has offered them a new practical rehabilitation tool. PMID:28157111

  14. Always on My Mind? Recognition of Attractive Faces May Not Depend on Attention.

    PubMed

    Silva, André; Macedo, António F; Albuquerque, Pedro B; Arantes, Joana

    2016-01-01

    Little research has examined what happens to attention and memory as a whole when humans see someone attractive. Hence, we investigated whether attractive stimuli gather more attention and are better remembered than unattractive stimuli. Participants took part in an attention task - in which matrices containing attractive and unattractive male naturalistic photographs were presented to 54 females, and measures of eye-gaze location and fixation duration using an eye-tracker were taken - followed by a recognition task. Eye-gaze was higher for the attractive stimuli compared to unattractive stimuli. Also, attractive photographs produced more hits and false recognitions than unattractive photographs which may indicate that regardless of attention allocation, attractive photographs produce more correct but also more false recognitions. We present an evolutionary explanation for this, as attending to more attractive faces but not always remembering them accurately and differentially compared with unseen attractive faces, may help females secure mates with higher reproductive value.

  15. Investigating Intrinsic and Extrinsic Variables During Simulated Internet Search

    NASA Technical Reports Server (NTRS)

    Liechty, Molly M.; Madhavan, Poornima

    2011-01-01

    Using an eye tracker we examined decision-making processes during an internet search task. Twenty experienced homebuyers and twenty-five undergraduates from Old Dominion University viewed homes on a simulated real estate website. Several of the homes included physical properties that had the potential to negatively impact individual perceptions. These negative externalities were either easy to change (Level 1) or impossible to change (Level 2). Eye movements were analyzed to examine the relationship between participants' "stated preferences"[verbalized preferences], "revealed preferences" [actual decisions[, and experience. Dwell times, fixation durations/counts, and saccade counts/amplitudes were analyzed. Results revealed that experienced homebuyers demonstrated a more refined search pattern than novice searchers. Experienced homebuyers were also less impacted by negative externalities. Furthermore, stated preferences were discrepant from revealed preferences; although participants initially stated they liked/disliked a graphic, their eye movement patterns did not reflect this trend. These results have important implications for design of user-friendly web interfaces.

  16. Commodity Tracker: Mobile Application for Food Security Monitoring in Haiti

    NASA Astrophysics Data System (ADS)

    Chiu, M. T.; Huang, X.; Baird, J.; Gourley, J. R.; Morelli, R.; de Lanerolle, T. R.; Haiti Food Security Monitoring Mobile App Team

    2011-12-01

    Megan Chiu, Jason Baird, Xu Huang, Trishan de Lanerolle, Ralph Morelli, Jonathan Gourley Trinity College, Computer Science Department and Environmental Science Program, 300 Summit Street, Hartford, CT 06106 megan.chiu@trincoll.edu, Jason.baird@trincoll.edu, xu.huang@trincoll.edu, trishan.delanerolle@trincoll.edu, ralph.morelli@trincoll.edu, jonathan.gourley@trincoll.edu Price data for Haiti commodities such as rice and potatoes have been traditionally recorded by hand on paper forms for many years. The information is then entered onto computer manually, thus making the process a long and arduous one. With the development of the Haiti Commodity Tracker mobile app, we are able to make this commodity price data recording process more efficient. Officials may use this information for making inferences about the difference in commodity prices and for food distribution during critical time after natural disasters. This information can also be utilized by governments and aid agencies on their food assistance programs. Agronomists record the item prices from several sample sites in a marketplace and compare those results from other markets across the region. Due to limited connectivity in rural areas, data is first saved to the phone's database and then retransmitted to a central server via SMS messaging. The mobile app is currently being field tested by an international NGO providing agricultural aid and support in rural Haiti.

  17. Is adaptation to perceived interocular differences in height explained by vertical fusional eye movements?

    PubMed

    Maier, Felix M; Schaeffel, Frank

    2013-07-24

    To find out whether adaptation to a vertical prism involves more than fusional vertical eye movements. Adaptation to a vertical base-up 3 prism diopter prism was measured in a custom-programmed Maddox test in nine visually normal emmetropic subjects (mean age 27.0 ± 2.8 years). Vertical eye movements were binocularly measured in six of the subjects with a custom-programmed binocular video eye tracker. In the Maddox test, some subjects adjusted the perceived height as expected from the power of the prism while others appeared to ignore the prism. After 15 minutes of adaptation, the interocular difference in perceived height was reduced by on average 51% (from 0.86°-0.44°). The larger the initially perceived difference in height in a subject, the larger the amplitude of adaptation was. Eye tracking showed that the prism generated divergent vertical eye movements of 1.2° on average, which was less than expected from its power. Differences in eye elevation were maintained as long as the prism was in place. Small angles of lateral head tilt generated large interocular differences in eye elevation, much larger than the effects introduced by the prism. Vertical differences in retinal image height were compensated by vertical fusional eye movements but some subjects responded poorly to a vertical prism in both experiments; fusional eye movements were generally too small to realign both foveae with the fixation target; and the prism adaptation in the Maddox test was fully explained by the changes in vertical eye position, suggesting that no further adaptational mechanism may be involved.

  18. Effects of aircraft windscreens and canopies on HMT/D aiming accuracy: III

    NASA Astrophysics Data System (ADS)

    Task, H. Lee; Goodyear, Chuck

    1999-07-01

    Modern fighter aircraft windscreens and canopies are typically made of curved, transparent plastic for improved aero-dynamics and bird-strike protection. Since they are curved these transparencies often refract light in such a way that a pilot looking through the transparency will see a target in a location other than where it really is. This effect has been known for many years and methods to correct the aircraft head- up display (HUD) for these angular deviations have been developed and employed. The same problem occurs for helmet- mounted display/trackers (HMD/Ts) used for target acquisition. However, in this case, the pilot can look through any part of the transparency instead of being constrained to just the forward section as in the case of the HUD and his/her head position can be anywhere in a rather large motion box. To explore the magnitude of these aiming errors several F-15, F- 16, F-18, and F-22 transparency systems were measured from a total of 12 different eye positions centered around the HMD Eye (the HMD Eye was defined to be a point 1.25 inches to the right of the aircraft Design Eye). The collection of eye points for assessing HMT/D aiming accuracy were: HMD Eye, 3 inches left and right of HMD Eye, 2 inches above HMD Eye, and 2 inches forward of HMD Eye plus all combinations of these. Results from these measurements along with recommendations regarding means of assessing 'goodness' of correction algorithms are presented.

  19. The Microstructure of Infants' Gaze as They View Adult Shifts in Overt Attention

    ERIC Educational Resources Information Center

    Gredeback, Gustaf; Theuring, Carolin; Hauf, Petra; Kenward, Ben

    2008-01-01

    We presented infants (5, 6, 9, and 12 months old) with movies in which a female model turned toward and fixated 1 of 2 toys placed on a table. Infants' gaze was measured using a Tobii 1750 eye tracker. Six-, 9-, and 12-month-olds' first gaze shift from the model's face (after the model started turning) was directed to the attended toy. The…

  20. Not All Past Events Are Equal: Biased Attention and Emerging Heuristics in Children's Past-to-Future Forecasting

    ERIC Educational Resources Information Center

    Lagattuta, Kristin Hansen; Sayfan, Liat

    2013-01-01

    Four- to 10-year-olds and adults (N = 265) responded to eight scenarios presented on an eye tracker. Each trial involved a character who encounters a perpetrator who had previously enacted positive (P), negative (N), or both types of actions toward him or her in varying sequences (NN, PP, PN, and NP). Participants predicted the character's…

  1. Binocular Glaucomatous Visual Field Loss and Its Impact on Visual Exploration - A Supermarket Study

    PubMed Central

    Aehling, Kathrin; Heister, Martin; Rosenstiel, Wolfgang; Schiefer, Ulrich; Papageorgiou, Elena

    2014-01-01

    Advanced glaucomatous visual field loss may critically interfere with quality of life. The purpose of this study was to (i) assess the impact of binocular glaucomatous visual field loss on a supermarket search task as an example of everyday living activities, (ii) to identify factors influencing the performance, and (iii) to investigate the related compensatory mechanisms. Ten patients with binocular glaucoma (GP), and ten healthy-sighted control subjects (GC) were asked to collect twenty different products chosen randomly in two supermarket racks as quickly as possible. The task performance was rated as “passed” or “failed” with regard to the time per correctly collected item. Based on the performance of control subjects, the threshold value for failing the task was defined as μ+3σ (in seconds per correctly collected item). Eye movements were recorded by means of a mobile eye tracker. Eight out of ten patients with glaucoma and all control subjects passed the task. Patients who failed the task needed significantly longer time (111.47 s ±12.12 s) to complete the task than patients who passed (64.45 s ±13.36 s, t-test, p<0.001). Furthermore, patients who passed the task showed a significantly higher number of glances towards the visual field defect (VFD) area than patients who failed (t-test, p<0.05). According to these results, glaucoma patients with defects in the binocular visual field display on average longer search times in a naturalistic supermarket task. However, a considerable number of patients, who compensate by frequent glancing towards the VFD, showed successful task performance. Therefore, systematic exploration of the VFD area seems to be a “time-effective” compensatory mechanism during the present supermarket task. PMID:25162522

  2. Binocular glaucomatous visual field loss and its impact on visual exploration--a supermarket study.

    PubMed

    Sippel, Katrin; Kasneci, Enkelejda; Aehling, Kathrin; Heister, Martin; Rosenstiel, Wolfgang; Schiefer, Ulrich; Papageorgiou, Elena

    2014-01-01

    Advanced glaucomatous visual field loss may critically interfere with quality of life. The purpose of this study was to (i) assess the impact of binocular glaucomatous visual field loss on a supermarket search task as an example of everyday living activities, (ii) to identify factors influencing the performance, and (iii) to investigate the related compensatory mechanisms. Ten patients with binocular glaucoma (GP), and ten healthy-sighted control subjects (GC) were asked to collect twenty different products chosen randomly in two supermarket racks as quickly as possible. The task performance was rated as "passed" or "failed" with regard to the time per correctly collected item. Based on the performance of control subjects, the threshold value for failing the task was defined as μ+3σ (in seconds per correctly collected item). Eye movements were recorded by means of a mobile eye tracker. Eight out of ten patients with glaucoma and all control subjects passed the task. Patients who failed the task needed significantly longer time (111.47 s ±12.12 s) to complete the task than patients who passed (64.45 s ±13.36 s, t-test, p < 0.001). Furthermore, patients who passed the task showed a significantly higher number of glances towards the visual field defect (VFD) area than patients who failed (t-test, p < 0.05). According to these results, glaucoma patients with defects in the binocular visual field display on average longer search times in a naturalistic supermarket task. However, a considerable number of patients, who compensate by frequent glancing towards the VFD, showed successful task performance. Therefore, systematic exploration of the VFD area seems to be a "time-effective" compensatory mechanism during the present supermarket task.

  3. Chromostereopsis in "virtual reality" adapters with electrically tuneable liquid lens oculars

    NASA Astrophysics Data System (ADS)

    Ozolinsh, Maris; Muizniece, Kristine; Berzinsh, Janis

    2016-10-01

    Chromostereopsis can be sight and feel in "Virtual Reality" adapters, that induces the appearance of color dependant depth sense and, finally, combines this sense with the source conceived depth scenario. Present studies are devoted to investigation the induced chromastereopsis when using adapted "Virtual Reality" frame together with mobile devices as smartphones. We did observation of composite visual stimuli presented on the high spatial resolution screen of the mobile phone placed inside a portable "Virtual Reality" adapter. Separated for the left and right eyes stimuli consisted of two areas: a) identical for both eyes color chromostereopsis part, and b) additional conventional color neutral random-dot stereopsis part with a stereodisparity based on the horizontal shift of a random-dot segment in images for the left and right eyes, correspondingly. The observer task was to equalize the depth sense for neutral and colored stimuli areas. Such scheme allows to determine actual observed chromostereopsis disparity value versus eye stimuli color difference. At standard observation conditions for adapter with +2D ocular lenses for mobile red-blue stimuli, the perceptual chromostereopsis depth sensitivity on color difference was linearly approximated with a slope SChS ≈ 2.1[arcmin/(Labcolor difference)] for red-blue pairs. Additional to standard application in adapter the tuneable "Varioptic" liquid lens oculars were incorporated, that allowed stimuli eye magnification, vergence and disparity values control electrically.

  4. Computer vision enhances mobile eye-tracking to expose expert cognition in natural-scene visual-search tasks

    NASA Astrophysics Data System (ADS)

    Keane, Tommy P.; Cahill, Nathan D.; Tarduno, John A.; Jacobs, Robert A.; Pelz, Jeff B.

    2014-02-01

    Mobile eye-tracking provides the fairly unique opportunity to record and elucidate cognition in action. In our research, we are searching for patterns in, and distinctions between, the visual-search performance of experts and novices in the geo-sciences. Traveling to regions resultant from various geological processes as part of an introductory field studies course in geology, we record the prima facie gaze patterns of experts and novices when they are asked to determine the modes of geological activity that have formed the scene-view presented to them. Recording eye video and scene video in natural settings generates complex imagery that requires advanced applications of computer vision research to generate registrations and mappings between the views of separate observers. By developing such mappings, we could then place many observers into a single mathematical space where we can spatio-temporally analyze inter- and intra-subject fixations, saccades, and head motions. While working towards perfecting these mappings, we developed an updated experiment setup that allowed us to statistically analyze intra-subject eye-movement events without the need for a common domain. Through such analyses we are finding statistical differences between novices and experts in these visual-search tasks. In the course of this research we have developed a unified, open-source, software framework for processing, visualization, and interaction of mobile eye-tracking and high-resolution panoramic imagery.

  5. Testing of visual field with virtual reality goggles in manual and visual grasp modes.

    PubMed

    Wroblewski, Dariusz; Francis, Brian A; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas

    2014-01-01

    Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4-6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode.

  6. Investigation of visual fatigue/discomfort generated by S3D video using eye-tracking data

    NASA Astrophysics Data System (ADS)

    Iatsun, Iana; Larabi, Mohamed-Chaker; Fernandez-Maloigne, Christine

    2013-03-01

    Stereoscopic 3D is undoubtedly one of the most attractive content. It has been deployed intensively during the last decade through movies and games. Among the advantages of 3D are the strong involvement of viewers and the increased feeling of presence. However, the sanitary e ects that can be generated by 3D are still not precisely known. For example, visual fatigue and visual discomfort are among symptoms that an observer may feel. In this paper, we propose an investigation of visual fatigue generated by 3D video watching, with the help of eye-tracking. From one side, a questionnaire, with the most frequent symptoms linked with 3D, is used in order to measure their variation over time. From the other side, visual characteristics such as pupil diameter, eye movements ( xations and saccades) and eye blinking have been explored thanks to data provided by the eye-tracker. The statistical analysis showed an important link between blinking duration and number of saccades with visual fatigue while pupil diameter and xations are not precise enough and are highly dependent on content. Finally, time and content play an important role in the growth of visual fatigue due to 3D watching.

  7. Eying the future: Eye movement in past and future thinking.

    PubMed

    El Haj, Mohamad; Lenoble, Quentin

    2017-06-07

    We investigated eye movement during past and future thinking. Participants were invited to retrieve past events and to imagine future events while their scan path was recorded by an eye-tracker. Past thinking triggered more fixation (p < .05), and saccade counts (p < .05) than future thinking. Past and future thinking triggered a similar duration of fixations and saccades, as well as a similar amplitude of saccades. Interestingly, participants rated past thinking as more vivid than future thinking (p < .01). Therefore, the vividness of past thinking seems to be accompanied by an increased number of fixations and saccades. Fixations and saccades in past thinking can be interpreted as an attempt by the visual system to find (through saccades) and activate (through fixations) stored memory representations. The same interpretation can be applied to future thinking as this ability requires activation of past experiences. However, future thinking triggers fewer fixations and saccades than past thinking: this may be due to its decreased demand on visual imagery, but could also be related to a potentially deleterious effect of eye movements on spatial imagery required for future thinking. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Eye-tracking the own-race bias in face recognition: revealing the perceptual and socio-cognitive mechanisms.

    PubMed

    Hills, Peter J; Pake, J Michael

    2013-12-01

    Own-race faces are recognised more accurately than other-race faces and may even be viewed differently as measured by an eye-tracker (Goldinger, Papesh, & He, 2009). Alternatively, observer race might direct eye-movements (Blais, Jack, Scheepers, Fiset, & Caldara, 2008). Observer differences in eye-movements are likely to be based on experience of the physiognomic characteristics that are differentially discriminating for Black and White faces. Two experiments are reported that employed standard old/new recognition paradigms in which Black and White observers viewed Black and White faces with their eye-movements recorded. Experiment 1 showed that there were observer race differences in terms of the features scanned but observers employed the same strategy across different types of faces. Experiment 2 demonstrated that other-race faces could be recognised more accurately if participants had their first fixation directed to more diagnostic features using fixation crosses. These results are entirely consistent with those presented by Blais et al. (2008) and with the perceptual interpretation that the own-race bias is due to inappropriate attention allocated to the facial features (Hills & Lewis, 2006, 2011). Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Internal health locus of control predicts willingness to track health behaviors online and with smartphone applications.

    PubMed

    Bennett, Brooke L; Goldstein, Carly M; Gathright, Emily C; Hughes, Joel W; Latner, Janet D

    2017-12-01

    Given rising technology use across all demographic groups, digital interventions offer a potential strategy for increasing access to health information and care. Research is lacking on identifying individual differences that impact willingness to use digital interventions, which may affect patient engagement. Health locus of control, the amount of control an individual believes they have over their own health, may predict willingness to use mobile health (mHealth) applications ('apps') and online trackers. A cross-sectional study (n = 276) was conducted to assess college students' health locus of control beliefs and willingness to use health apps and online trackers. Internal and powerful other health locus of control beliefs predicted willingness to use health apps and online trackers while chance health locus of control beliefs did not. Individuals with internal and powerful other health locus of control beliefs are more willing than those with chance health locus of control beliefs to utilize a form of technology to monitor or change health behaviors. Health locus of control is an easy-to-assess patient characteristic providers can measure to identify which patients are more likely to utilize mHealth apps and online trackers.

  10. BeefTracker: Spatial Tracking and Geodatabase for Beef Herd Sustainability and Lifecycle Analysis

    NASA Astrophysics Data System (ADS)

    Oltjen, J. W.; Stackhouse, J.; Forero, L.; Stackhouse-Lawson, K.

    2015-12-01

    We have developed a web-based mapping platform named "BeefTracker" to provide beef cattle ranchers a tool to determine how cattle production fits within sustainable ecosystems and to provide regional data to update beef sustainability lifecycle analysis. After initial identification and mapping of pastures, herd data (class and number of animals) are input on a mobile device in the field with a graphical pasture interface, stored in the cloud, and linked via the web to a personal computer for inventory tracking and analysis. Pasture use calculated on an animal basis provides quantifiable data regarding carrying capacity and subsequent beef production to provide more accurate data inputs for beef sustainability lifecycle analysis. After initial testing by university range scientists and ranchers we have enhanced the BeefTracker application to work when cell service is unavailable and to improve automation for increased ease of use. Thus far experiences with BeefTracker have been largely positive, due to livestock producers' perception of the need for this type of software application and its intuitive interface. We are now in the process of education to increase its use throughout the U.S.

  11. Creation and use of a survey instrument for comparing mobile computing devices.

    PubMed

    Macri, Jennifer M; Lee, Paul P; Silvey, Garry M; Lobach, David F

    2005-01-01

    Both personal digital assistants (PDAs) and tablet computers have emerged to facilitate data collection at the point of care. However, little research has been reported comparing these mobile computing devices in specific care settings. In this study we present an approach for comparing functionally identical applications on a Palm operating system-based PDA and a Windows-based tablet computer for point-of-care documentation of clinical observations by eye care professionals when caring for patients with diabetes. Eye-care professionals compared the devices through focus group sessions and through validated usability surveys. This poster describes the development and use of the survey instrument used for comparing mobile computing devices.

  12. Reading strategies in mild to moderate strabismic amblyopia: an eye movement investigation.

    PubMed

    Kanonidou, Evgenia; Proudlock, Frank A; Gottlob, Irene

    2010-07-01

    PURPOSE. To investigate oculomotor strategies in strabismic amblyopia and evaluate abnormalities during monocular and binocular reading. METHODS. Eye movements were recorded with a head-mounted infrared video eye-tracker (250 Hz, <0.01 degrees resolution) in 20 strabismic amblyopes (mean age, 44.9 +/- 10.7 years) and 20 normal control subjects (mean age, 42.8 +/- 10.9 years) while they silently read paragraphs of text. Monocular reading comparisons were made between the amblyopic eye and the nondominant eye of control subjects and the nonamblyopic eye and the dominant eye of the control subjects. Binocular reading between the amblyopic and control subjects was also compared. RESULTS. Mean reading speed, number of progressive and regressive saccades per line, saccadic amplitude (of progressive saccades), and fixation duration were estimated. Inter- and intrasubject statistical comparisons were made. Reading speed was significantly slower in amblyopes than in control subjects during monocular reading with amblyopic (13.094 characters/s vs. 22.188 characters/s; P < 0.0001) and nonamblyopic eyes (16.241 characters/s vs. 22.349 characters/s, P < 0.0001), and binocularly (15.698 characters/s vs. 23.425 characters/s, P < 0.0001). In amblyopes, reading was significantly slower with the amblyopic eye than with the nonamblyopic eye in binocular viewing (P < 0.05). These differences were associated with significantly more regressive saccades and longer fixation durations, but not with changes in saccadic amplitudes. CONCLUSIONS. In strabismic amblyopia, reading is impaired, not only during monocular viewing with the amblyopic eye, but also with the nonamblyopic eye and binocularly, even though normal visual acuity pertains to the latter two conditions. The impaired reading performance is associated with differences in both the saccadic and fixational patterns, most likely as adaptation strategies to abnormal sensory experiences such as crowding and suppression.

  13. Photorefractive keratectomy with a small spot laser and tracker.

    PubMed

    Pallikaris, I G; Koufala, K I; Siganos, D S; Papadaki, T G; Katsanevaki, V J; Tourtsan, V; McDonald, M B

    1999-01-01

    The Autonomous Technologies LADARVision excimer laser system utilizes an eye tracking mechanism and a small spot for photorefractive keratectomy. One hundred and two eyes of 102 patients were treated for -1.50 to -6.25 D of spherical myopia at the spectacle plane using a 6-mm diameter ablation zone. One year follow-up was available for 93 eyes (91%). Uncorrected visual acuity for eyes treated for distance vision was 20/40 or better in 99% (n = 90), and 20/20 or better in 70% (n = 64) of eyes at 12 months. Spectacle-corrected visual acuity was 20/25 or better in all 92 eyes reported; no eye lost more than 2 lines of spectacle-corrected visual acuity, and only 1 eye (1.0%) experienced a loss of 2 lines (20/12.5 to 20/20) at 1 year. The refractive result was within +/- 0.50 D of the desired correction in 75% (n = 70), and within +/- 1.00 D in 93% (n = 86) of eyes at 12 months. Refractive stability was achieved between 3 and 6 months. Corneal haze was graded as trace or less in 100% of the 93 eyes. No significant reductions were noted in contrast sensitivity or endothelial cell density. Patients treated with the Autonomous Technologies LADARVision excimer laser system for -1.50 to -6.25 D of spherical myopia with 1 year follow-up had uncorrected visual acuity of 20/20 or better in 70%, no significant loss of spectacle-corrected visual acuity, no reduction of endothelial cell density or contrast sensitivity, and low levels of corneal haze.

  14. A Relationship Between Visual Complexity and Aesthetic Appraisal of Car Front Images: An Eye-Tracker Study.

    PubMed

    Chassy, Philippe; Lindell, Trym A E; Jones, Jessica A; Paramei, Galina V

    2015-01-01

    Image aesthetic pleasure (AP) is conjectured to be related to image visual complexity (VC). The aim of the present study was to investigate whether (a) two image attributes, AP and VC, are reflected in eye-movement parameters; and (b) subjective measures of AP and VC are related. Participants (N=26) explored car front images (M=50) while their eye movements were recorded. Following image exposure (10 seconds), its VC and AP were rated. Fixation count was found to positively correlate with the subjective VC and its objective proxy, JPEG compression size, suggesting that this eye-movement parameter can be considered an objective behavioral measure of VC. AP, in comparison, positively correlated with average dwelling time. Subjective measures of AP and VC were related too, following an inverted U-shape function best-fit by a quadratic equation. In addition, AP was found to be modulated by car prestige. Our findings reveal a close relationship between subjective and objective measures of complexity and aesthetic appraisal, which is interpreted within a prototype-based theory framework. © The Author(s) 2015.

  15. A digitally implemented preambleless demodulator for maritime and mobile data communications

    NASA Astrophysics Data System (ADS)

    Chalmers, Harvey; Shenoy, Ajit; Verahrami, Farhad B.

    The hardware design and software algorithms for a low-bit-rate, low-cost, all-digital preambleless demodulator are described. The demodulator operates under severe high-noise conditions, fast Doppler frequency shifts, large frequency offsets, and multipath fading. Sophisticated algorithms, including a fast Fourier transform (FFT)-based burst acquisition algorithm, a cycle-slip resistant carrier phase tracker, an innovative Doppler tracker, and a fast acquisition symbol synchronizer, were developed and extensively simulated for reliable burst reception. The compact digital signal processor (DSP)-based demodulator hardware uses a unique personal computer test interface for downloading test data files. The demodulator test results demonstrate a near-ideal performance within 0.2 dB of theory.

  16. Does walking speed mediate the association between visual impairment and self-report of mobility disability? The Salisbury Eye Evaluation Study.

    PubMed

    Swenor, Bonnielin K; Bandeen-Roche, Karen; Muñoz, Beatriz; West, Sheila K

    2014-08-01

    To determine whether performance speeds mediate the association between visual impairment and self-reported mobility disability over an 8-year period. Longitudinal analysis. Salisbury, Maryland. Salisbury Eye Evaluation Study participants aged 65 and older (N=2,520). Visual impairment was defined as best-corrected visual acuity worse than 20/40 in the better-seeing eye or visual field less than 20°. Self-reported mobility disability on three tasks was assessed: walking up stairs, walking down stairs, and walking 150 feet. Performance speed on three similar tasks was measured: walking up steps (steps/s), walking down steps (steps/s), and walking 4 m (m/s). For each year of observation, the odds of reporting mobility disability was significantly greater for participants who were visually impaired (VI) than for those who were not (NVI) (odds ratio (OR) difficulty walking up steps=1.58, 95% confidence interval (CI)=1.32-1.89; OR difficulty walking down steps=1.90, 95% CI=1.59-2.28; OR difficulty walking 150 feet=2.11, 95% CI=1.77-2.51). Once performance speed on a similar mobility task was included in the models, VI participants were no longer more likely to report mobility disability than those who were NVI (OR difficulty walking up steps=0.84, 95% CI=0.65-1.11; OR difficulty walking down steps=0.96, 95% CI=0.74-1.24; OR difficulty walking 150 feet=1.22, 95% CI=0.98-1.50). Slower performance speed in VI individuals largely accounted for the difference in the odds of reporting mobility disability, suggesting that VI older adults walk slower and are therefore more likely to report mobility disability than those who are NVI. Improving mobility performance in older adults with visual impairment may minimize the perception of mobility disability. © 2014, Copyright the Authors Journal compilation © 2014, The American Geriatrics Society.

  17. Algorithmic Skin: Health-Tracking Technologies, Personal Analytics and the Biopedagogies of Digitized Health and Physical Education

    ERIC Educational Resources Information Center

    Williamson, Ben

    2015-01-01

    The emergence of digitized health and physical education, or "eHPE", embeds software algorithms in the organization of health and physical education pedagogies. Particularly with the emergence of wearable and mobile activity trackers, biosensors and personal analytics apps, algorithmic processes have an increasingly powerful part to play…

  18. Reading Words or Pictures: Eye Movement Patterns in Adults and Children Differ by Age Group and Receptive Language Ability

    PubMed Central

    An, Licong; Wang, Yifang; Sun, Yadong

    2017-01-01

    This study was conducted to explore the differences in the degree of attention given to Chinese print and pictures by children and adults when they read picture books with and without Chinese words. We used an eye tracker from SensoMotoric Instruments to record the visual fixations of the subjects. The results showed that the adults paid more attention to Chinese print and looked at the print sooner than the children did. The stronger the children’s receptive language abilities were, the less time it took them to view the pictures. All participants spent the same amount of time looking at the pictures whether Chinese words were present or absent. PMID:28588526

  19. Quantitative, simultaneous, and collinear eye-tracked, high dynamic range optical coherence tomography at 850 and 1060 nm

    NASA Astrophysics Data System (ADS)

    Mooser, Matthias; Burri, Christian; Stoller, Markus; Luggen, David; Peyer, Michael; Arnold, Patrik; Meier, Christoph; Považay, Boris

    2017-07-01

    Ocular optical coherence tomography at the wavelengths ranges of 850 and 1060 nm have been integrated with a confocal scanning laser ophthalmoscope eye-tracker as a clinical commercial-class system. Collinear optics enables an exact overlap of the different channels to produce precisely overlapping depth-scans for evaluating the similarities and differences between the wavelengths to extract additional physiologic information. A reliable segmentation algorithm utilizing Graphcuts has been implemented and applied to automatically extract retinal and choroidal shape in cross-sections and volumes. The device has been tested in normals and pathologies including a cross-sectional and longitudinal study of myopia progress and control with a duplicate instrument in Asian children.

  20. CrossTalk: The Journal of Defense Software Engineering. Volume 18, Number 11

    DTIC Science & Technology

    2005-11-01

    languages. Our discipline of software engineering has really experienced phenomenal growth right before our eyes. A sign that software design has...approach on a high level of abstraction. The main emphasis is on the identification and allocation of a needed functionality (e.g., a target tracker ), rather...messaging software that is the backbone of teenage culture. As increasing security constraints will increase the cost of developing and main- taining any

  1. Tracker Mindset for Explosive Device Emplacement Indicator Detection

    DTIC Science & Technology

    2014-09-01

    NOTES 14. ABSTRACT While investigating landmine detection training for the AN/PSS-14, we noticed operators were so focused on the detector’s auditory ...traces? 1.1.1 How Humans See Basically speaking, when light from the environment enters the eye, it stimulates the rod and cone photoreceptors on...contours or edges more visible. 31 Intuition Can targets, in some way, be detected at a level below conscious awareness? Can stimulation , of which

  2. Implicit prosody mining based on the human eye image capture technology

    NASA Astrophysics Data System (ADS)

    Gao, Pei-pei; Liu, Feng

    2013-08-01

    The technology of eye tracker has become the main methods of analyzing the recognition issues in human-computer interaction. Human eye image capture is the key problem of the eye tracking. Based on further research, a new human-computer interaction method introduced to enrich the form of speech synthetic. We propose a method of Implicit Prosody mining based on the human eye image capture technology to extract the parameters from the image of human eyes when reading, control and drive prosody generation in speech synthesis, and establish prosodic model with high simulation accuracy. Duration model is key issues for prosody generation. For the duration model, this paper put forward a new idea for obtaining gaze duration of eyes when reading based on the eye image capture technology, and synchronous controlling this duration and pronunciation duration in speech synthesis. The movement of human eyes during reading is a comprehensive multi-factor interactive process, such as gaze, twitching and backsight. Therefore, how to extract the appropriate information from the image of human eyes need to be considered and the gaze regularity of eyes need to be obtained as references of modeling. Based on the analysis of current three kinds of eye movement control model and the characteristics of the Implicit Prosody reading, relative independence between speech processing system of text and eye movement control system was discussed. It was proved that under the same text familiarity condition, gaze duration of eyes when reading and internal voice pronunciation duration are synchronous. The eye gaze duration model based on the Chinese language level prosodic structure was presented to change previous methods of machine learning and probability forecasting, obtain readers' real internal reading rhythm and to synthesize voice with personalized rhythm. This research will enrich human-computer interactive form, and will be practical significance and application prospect in terms of disabled assisted speech interaction. Experiments show that Implicit Prosody mining based on the human eye image capture technology makes the synthesized speech has more flexible expressions.

  3. Driving with Binocular Visual Field Loss? A Study on a Supervised On-Road Parcours with Simultaneous Eye and Head Tracking

    PubMed Central

    Aehling, Kathrin; Heister, Martin; Rosenstiel, Wolfgang; Schiefer, Ulrich; Papageorgiou, Elena

    2014-01-01

    Post-chiasmal visual pathway lesions and glaucomatous optic neuropathy cause binocular visual field defects (VFDs) that may critically interfere with quality of life and driving licensure. The aims of this study were (i) to assess the on-road driving performance of patients suffering from binocular visual field loss using a dual-brake vehicle, and (ii) to investigate the related compensatory mechanisms. A driving instructor, blinded to the participants' diagnosis, rated the driving performance (passed/failed) of ten patients with homonymous visual field defects (HP), including four patients with right (HR) and six patients with left homonymous visual field defects (HL), ten glaucoma patients (GP), and twenty age and gender-related ophthalmologically healthy control subjects (C) during a 40-minute driving task on a pre-specified public on-road parcours. In order to investigate the subjects' visual exploration ability, eye movements were recorded by means of a mobile eye tracker. Two additional cameras were used to monitor the driving scene and record head and shoulder movements. Thus this study is novel as a quantitative assessment of eye movements and an additional evaluation of head and shoulder was performed. Six out of ten HP and four out of ten GP were rated as fit to drive by the driving instructor, despite their binocular visual field loss. Three out of 20 control subjects failed the on-road assessment. The extent of the visual field defect was of minor importance with regard to the driving performance. The site of the homonymous visual field defect (HVFD) critically interfered with the driving ability: all failed HP subjects suffered from left homonymous visual field loss (HL) due to right hemispheric lesions. Patients who failed the driving assessment had mainly difficulties with lane keeping and gap judgment ability. Patients who passed the test displayed different exploration patterns than those who failed. Patients who passed focused longer on the central area of the visual field than patients who failed the test. In addition, patients who passed the test performed more glances towards the area of their visual field defect. In conclusion, our findings support the hypothesis that the extent of visual field per se cannot predict driving fitness, because some patients with HVFDs and advanced glaucoma can compensate for their deficit by effective visual scanning. Head movements appeared to be superior to eye and shoulder movements in predicting the outcome of the driving test under the present study scenario. PMID:24523869

  4. Tracker-on-C for cone-beam CT-guided surgery: evaluation of geometric accuracy and clinical applications

    NASA Astrophysics Data System (ADS)

    Reaungamornrat, S.; Otake, Y.; Uneri, A.; Schafer, S.; Mirota, D. J.; Nithiananthan, S.; Stayman, J. W.; Khanna, A. J.; Reh, D. D.; Gallia, G. L.; Taylor, R. H.; Siewerdsen, J. H.

    2012-02-01

    Conventional surgical tracking configurations carry a variety of limitations in line-of-sight, geometric accuracy, and mismatch with the surgeon's perspective (for video augmentation). With increasing utilization of mobile C-arms, particularly those allowing cone-beam CT (CBCT), there is opportunity to better integrate surgical trackers at bedside to address such limitations. This paper describes a tracker configuration in which the tracker is mounted directly on the Carm. To maintain registration within a dynamic coordinate system, a reference marker visible across the full C-arm rotation is implemented, and the "Tracker-on-C" configuration is shown to provide improved target registration error (TRE) over a conventional in-room setup - (0.9+/-0.4) mm vs (1.9+/-0.7) mm, respectively. The system also can generate digitally reconstructed radiographs (DRRs) from the perspective of a tracked tool ("x-ray flashlight"), the tracker, or the C-arm ("virtual fluoroscopy"), with geometric accuracy in virtual fluoroscopy of (0.4+/-0.2) mm. Using a video-based tracker, planning data and DRRs can be superimposed on the video scene from a natural perspective over the surgical field, with geometric accuracy (0.8+/-0.3) pixels for planning data overlay and (0.6+/-0.4) pixels for DRR overlay across all C-arm angles. The field-of-view of fluoroscopy or CBCT can also be overlaid on real-time video ("Virtual Field Light") to assist C-arm positioning. The fixed transformation between the x-ray image and tracker facilitated quick, accurate intraoperative registration. The workflow and precision associated with a variety of realistic surgical tasks were significantly improved using the Tracker-on-C - for example, nearly a factor of 2 reduction in time required for C-arm positioning, reduction or elimination of dose in "hunting" for a specific fluoroscopic view, and confident placement of the x-ray FOV on the surgical target. The proposed configuration streamlines the integration of C-arm CBCT with realtime tracking and demonstrated utility in a spectrum of image-guided interventions (e.g., spine surgery) benefiting from improved accuracy, enhanced visualization, and reduced radiation exposure.

  5. Determinants for Sustained Use of an Activity Tracker: Observational Study

    PubMed Central

    Moons, Jonas; Kerkhof, Peter; Wiekens, Carina; De Groot, Martijn

    2017-01-01

    Background A lack of physical activity is considered to cause 6% of deaths globally. Feedback from wearables such as activity trackers has the potential to encourage daily physical activity. To date, little research is available on the natural development of adherence to activity trackers or on potential factors that predict which users manage to keep using their activity tracker during the first year (and thereby increasing the chance of healthy behavior change) and which users discontinue using their trackers after a short time. Objective The aim of this study was to identify the determinants for sustained use in the first year after purchase. Specifically, we look at the relative importance of demographic and socioeconomic, psychological, health-related, goal-related, technological, user experience–related, and social predictors of feedback device use. Furthermore, this study tests the effect of these predictors on physical activity. Methods A total of 711 participants from four urban areas in France received an activity tracker (Fitbit Zip) and gave permission to use their logged data. Participants filled out three Web-based questionnaires: at start, after 98 days, and after 232 days to measure the aforementioned determinants. Furthermore, for each participant, we collected activity data tracked by their Fitbit tracker for 320 days. We determined the relative importance of all included predictors by using Random Forest, a machine learning analysis technique. Results The data showed a slow exponential decay in Fitbit use, with 73.9% (526/711) of participants still tracking after 100 days and 16.0% (114/711) of participants tracking after 320 days. On average, participants used the tracker for 129 days. Most important reasons to quit tracking were technical issues such as empty batteries and broken trackers or lost trackers (21.5% of all Q3 respondents, 130/601). Random Forest analysis of predictors revealed that the most influential determinants were age, user experience–related factors, mobile phone type, household type, perceived effect of the Fitbit tracker, and goal-related factors. We explore the role of those predictors that show meaningful differences in the number of days the tracker was worn. Conclusions This study offers an overview of the natural development of the use of an activity tracker, as well as the relative importance of a range of determinants from literature. Decay is exponential but slower than may be expected from existing literature. Many factors have a small contribution to sustained use. The most important determinants are technical condition, age, user experience, and goal-related factors. This finding suggests that activity tracking is potentially beneficial for a broad range of target groups, but more attention should be paid to technical and user experience–related aspects of activity trackers. PMID:29084709

  6. Does Guiding Toward Task-Relevant Information Help Improve Graph Processing and Graph Comprehension of Individuals with Low or High Numeracy? An Eye-Tracker Experiment.

    PubMed

    Keller, Carmen; Junghans, Alex

    2017-11-01

    Individuals with low numeracy have difficulties with understanding complex graphs. Combining the information-processing approach to numeracy with graph comprehension and information-reduction theories, we examined whether high numerates' better comprehension might be explained by their closer attention to task-relevant graphical elements, from which they would expect numerical information to understand the graph. Furthermore, we investigated whether participants could be trained in improving their attention to task-relevant information and graph comprehension. In an eye-tracker experiment ( N = 110) involving a sample from the general population, we presented participants with 2 hypothetical scenarios (stomach cancer, leukemia) showing survival curves for 2 treatments. In the training condition, participants received written instructions on how to read the graph. In the control condition, participants received another text. We tracked participants' eye movements while they answered 9 knowledge questions. The sum constituted graph comprehension. We analyzed visual attention to task-relevant graphical elements by using relative fixation durations and relative fixation counts. The mediation analysis revealed a significant ( P < 0.05) indirect effect of numeracy on graph comprehension through visual attention to task-relevant information, which did not differ between the 2 conditions. Training had a significant main effect on visual attention ( P < 0.05) but not on graph comprehension ( P < 0.07). Individuals with high numeracy have better graph comprehension due to their greater attention to task-relevant graphical elements than individuals with low numeracy. With appropriate instructions, both groups can be trained to improve their graph-processing efficiency. Future research should examine (e.g., motivational) mediators between visual attention and graph comprehension to develop appropriate instructions that also result in higher graph comprehension.

  7. Mobile phones and sleep - A review

    NASA Astrophysics Data System (ADS)

    Supe, Sanjay S.

    2010-01-01

    The increasing use of mobile phones has raised concerns regarding the potential health effects of exposure to the radiofrequency electromagnetic fields. An increasing amount research related to mobile phone use has focussed on the possible effects of mobile phone exposure on human brain activity and function. In particular, the use of sleep research has become a more widely used technique for assessing the possible effects of mobile phones on human health and wellbeing especially in the investigation of potential changes in sleep architecture resulting from mobile phone use. Acute exposure to a mobile phone prior to sleep significantly enhances electroencephalogram spectral power in the sleep spindle frequency range. This mobile phone-induced enhancement in spectral power is largely transitory and does not linger throughout the night. Furthermore, a reduction in rapid eye movement sleep latency following mobile phone exposure was also found, although interestingly, neither this change in rapid eye movement sleep latency or the enhancement in spectral power following mobile phone exposure, led to changes in the overall quality of sleep. In conclusion, a short exposure to the radiofrequency electromagnetic fields emitted by a mobile phone handset immediately prior to sleep is sufficient to induce changes in brain activity in the initial part of sleep. The consequences or functional significance of this effect are currently unknown and it would be premature to draw conclusions about possible health consequences.

  8. Mapping and correcting the influence of gaze position on pupil size measurements

    PubMed Central

    Petrov, Alexander A.

    2015-01-01

    Pupil size is correlated with a wide variety of important cognitive variables and is increasingly being used by cognitive scientists. Pupil data can be recorded inexpensively and non-invasively by many commonly used video-based eye-tracking cameras. Despite the relative ease of data collection and increasing prevalence of pupil data in the cognitive literature, researchers often underestimate the methodological challenges associated with controlling for confounds that can result in misinterpretation of their data. One serious confound that is often not properly controlled is pupil foreshortening error (PFE)—the foreshortening of the pupil image as the eye rotates away from the camera. Here we systematically map PFE using an artificial eye model and then apply a geometric model correction. Three artificial eyes with different fixed pupil sizes were used to systematically measure changes in pupil size as a function of gaze position with a desktop EyeLink 1000 tracker. A grid-based map of pupil measurements was recorded with each artificial eye across three experimental layouts of the eye-tracking camera and display. Large, systematic deviations in pupil size were observed across all nine maps. The measured PFE was corrected by a geometric model that expressed the foreshortening of the pupil area as a function of the cosine of the angle between the eye-to-camera axis and the eye-to-stimulus axis. The model reduced the root mean squared error of pupil measurements by 82.5 % when the model parameters were pre-set to the physical layout dimensions, and by 97.5 % when they were optimized to fit the empirical error surface. PMID:25953668

  9. The Cerebellar Dysplasia of Chiari II Malformation as Revealed by Eye Movements

    PubMed Central

    Salman, Michael S.; Dennis, Maureen; Sharpe, James A.

    2011-01-01

    Introduction Chiari type II malformation (CII) is a developmental deformity of the hindbrain. We have previously reported that many patients with CII have impaired smooth pursuit, while few make inaccurate saccades or have an abnormal vestibulo-ocular reflex. In contrast, saccadic adaptation and visual fixation are normal. In this report, we correlate results from several eye movement studies with neuroimaging in CII. We present a model for structural changes within the cerebellum in CII. Methods Saccades, smooth pursuit, the vestibulo-ocular reflex, and visual fixation were recorded in 21 patients with CII, aged 8–19 years and 39 age-matched controls, using an infrared eye tracker. Qualitative and quantitative MRI data were correlated with eye movements in 19 CII patients and 28 controls. Results Nine patients with CII had abnormal eye movements. Smooth pursuit gain was subnormal in eight, saccadic accuracy abnormal in four, and vestibulo-ocular reflex gain abnormal in three. None had fixation instability. Patients with CII had a significantly smaller cerebellar volume than controls, and those with normal eye motion had an expanded midsagittal vermis compared to controls. However, patients with abnormal eye movements had a smaller (non-expanded) midsagittal vermis area, posterior fossa area and medial cerebellar volumes than CII patients with normal eye movements. Conclusions The deformity of CII affects the structure and function of the cerebellum selectively and differently in those with abnormal eye movements. We propose that the vermis can expand when compressed within a small posterior fossa in some CII patients, thus sparing its ocular motor functions. PMID:19960749

  10. Navigation system for a mobile robot with a visual sensor using a fish-eye lens

    NASA Astrophysics Data System (ADS)

    Kurata, Junichi; Grattan, Kenneth T. V.; Uchiyama, Hironobu

    1998-02-01

    Various position sensing and navigation systems have been proposed for the autonomous control of mobile robots. Some of these systems have been installed with an omnidirectional visual sensor system that proved very useful in obtaining information on the environment around the mobile robot for position reckoning. In this article, this type of navigation system is discussed. The sensor is composed of one TV camera with a fish-eye lens, using a reference target on a ceiling and hybrid image processing circuits. The position of the robot, with respect to the floor, is calculated by integrating the information obtained from a visual sensor and a gyroscope mounted in the mobile robot, and the use of a simple algorithm based on PTP control for guidance is discussed. An experimental trial showed that the proposed system was both valid and useful for the navigation of an indoor vehicle.

  11. Brief Report: Patterns of Eye Movements in Face to Face Conversation Are Associated with Autistic Traits--Evidence from a Student Sample

    ERIC Educational Resources Information Center

    Vabalas, Andrius; Freeth, Megan

    2016-01-01

    The current study investigated whether the amount of autistic traits shown by an individual is associated with viewing behaviour during a face-to-face interaction. The eye movements of 36 neurotypical university students were recorded using a mobile eye-tracking device. High amounts of autistic traits were neither associated with reduced looking…

  12. Four-year to seven-year outcomes of advanced surface ablation with excimer laser for high myopia.

    PubMed

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob; Grønbech, Keea Treu; Vestergaard, Anders Højslet

    2015-07-01

    We aimed to evaluate and compare outcomes after photorefractive keratectomy with cooling (cPRK) and laser-assisted subepithelial keratectomy (LASEK) for high myopia. This was a retrospective, single-masked follow-up study of patients treated for myopia between 2007 and 2009 with cPRK or LASEK, using a high-frequency flying-spot excimer laser with eye-tracker (MEL80; Carl Zeiss, Jena, Germany). One eye of each patient was randomly chosen for analysis. Re-treated eyes were excluded. Forty-six cPRK patients and 35 LASEK patients were included. Spherical equivalent averaged -7.69 ± 1.47 diopters (D) in cPRK eyes and -7.98 ± 2.06 D in LASEK eyes (p = 0.31) before surgery. The average follow-up time was 4.6 years in cPRK patients and 6.0 years in LASEK patients (p < 0.05). At final follow-up, no cPRK eyes and one LASEK eye (p = 0.46) had lost two lines of corrected distance visual acuity (CDVA). No eyes had significant haze at final follow-up, although trace haze was found in four cPRK eyes and six LASEK eyes (p = 0.44). However, at 6 weeks after surgery, zero cPRK eyes and nine LASEK eyes (p < 0.05) had significant haze. At final follow-up, 63 % of cPRK eyes and 35 % of LASEK eyes (p = 0.17) were within ±1.0 D of intended refraction. Finally, 100 % of cPRK patients and 92 % of LASEK patients (p = 0.87) were satisfied or very satisfied with the surgery at final follow-up. cPRK and LASEK seemed safe and with high patient satisfaction 4 to 7 years after surgery for high myopia. However, cPRK was more effective than LASEK in reducing initial significant corneal haze.

  13. A Pilot Study of Horizontal Head and Eye Rotations in Baseball Batting.

    PubMed

    Fogt, Nick; Persson, Tyler W

    2017-08-01

    The purpose of the study was to measure and compare horizontal head and eye tracking movements as baseball batters "took" pitches and swung at baseball pitches. Two former college baseball players were tested in two conditions. A pitching machine was used to project tennis balls toward the subjects. In the first condition, subjects acted as if they were taking (i.e., not swinging) the pitches. In the second condition, subjects attempted to bat the pitched balls. Head movements were measured with an inertial sensor; eye movements were measured with a video eye tracker. For each condition, the relationship between the horizontal head and eye rotations was similar for the two subjects, as were the overall head-, eye-, and gaze-tracking strategies. In the "take" condition, head movements in the direction of the ball were larger than eye movements for much of the pitch trajectory. Large eye movements occurred only late in the pitch trajectory. Gaze was directed near the ball until approximately 150 milliseconds before the ball arrived at the batter, at which time gaze was directed ahead of the ball to a location near that occupied when the ball crosses the plate. In the "swing" condition, head movements in the direction of the ball were larger than eye movements throughout the pitch trajectory. Gaze was directed near the ball until approximately 50 to 60 milliseconds prior to pitch arrival at the batter. Horizontal head rotations were larger than horizontal eye rotations in both the "take" and "swing" conditions. Gaze was directed ahead of the ball late in the pitch trajectory in the "take" condition, whereas gaze was directed near the ball throughout much of the pitch trajectory in the "swing" condition.

  14. To exempt employment in the mobile amusement industry from the numerical limitation applicable to nonimmigrants provided status under section 101(a)(15)(H)(ii)(b) of the Immigration and Nationality Act.

    THOMAS, 111th Congress

    Rep. Djou, Charles K. [R-HI-1

    2010-09-22

    House - 12/20/2010 Referred to the Subcommittee on Immigration, Citizenship, Refugees, Border Security, and International Law. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  15. Forensic Spoorology: Seeing and Understanding Human Behavior through Observation, Classification and Interpretation of Spoor Evidence

    DTIC Science & Technology

    2011-06-10

    SASA Stride and Step Analysis SCS Spoor-Chain Signature SID Self -Imposed Distortion SMS Steadfast-Mind State SSA Secondary Spoor Area TEC Track...because there was no self -regulating body of professional trackers whom by education, training, and experience had come together to establish an...registered in soft ground or in snow by isolated tracks. This visibility gap in knowledge leaves an examiner‘s eyes outside the realm of linearity

  16. What You Learn is What You See: Using Eye Movements to Study Infant Cross-Situational Word Learning

    PubMed Central

    Smith, Linda

    2016-01-01

    Recent studies show that both adults and young children possess powerful statistical learning capabilities to solve the word-to-world mapping problem. However, the underlying mechanisms that make statistical learning possible and powerful are not yet known. With the goal of providing new insights into this issue, the research reported in this paper used an eye tracker to record the moment-by-moment eye movement data of 14-month-old babies in statistical learning tasks. Various measures are applied to such fine-grained temporal data, such as looking duration and shift rate (the number of shifts in gaze from one visual object to the other) trial by trial, showing different eye movement patterns between strong and weak statistical learners. Moreover, an information-theoretic measure is developed and applied to gaze data to quantify the degree of learning uncertainty trial by trial. Next, a simple associative statistical learning model is applied to eye movement data and these simulation results are compared with empirical results from young children, showing strong correlations between these two. This suggests that an associative learning mechanism with selective attention can provide a cognitively plausible model of cross-situational statistical learning. The work represents the first steps to use eye movement data to infer underlying real-time processes in statistical word learning. PMID:22213894

  17. Testing of Visual Field with Virtual Reality Goggles in Manual and Visual Grasp Modes

    PubMed Central

    Wroblewski, Dariusz; Francis, Brian A.; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas

    2014-01-01

    Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4–6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode. PMID:25050326

  18. Obstacle Avoidance, Visual Detection Performance, and Eye-Scanning Behavior of Glaucoma Patients in a Driving Simulator: A Preliminary Study

    PubMed Central

    Prado Vega, Rocío; van Leeuwen, Peter M.; Rendón Vélez, Elizabeth; Lemij, Hans G.; de Winter, Joost C. F.

    2013-01-01

    The objective of this study was to evaluate differences in driving performance, visual detection performance, and eye-scanning behavior between glaucoma patients and control participants without glaucoma. Glaucoma patients (n = 23) and control participants (n = 12) completed four 5-min driving sessions in a simulator. The participants were instructed to maintain the car in the right lane of a two-lane highway while their speed was automatically maintained at 100 km/h. Additional tasks per session were: Session 1: none, Session 2: verbalization of projected letters, Session 3: avoidance of static obstacles, and Session 4: combined letter verbalization and avoidance of static obstacles. Eye-scanning behavior was recorded with an eye-tracker. Results showed no statistically significant differences between patients and control participants for lane keeping, obstacle avoidance, and eye-scanning behavior. Steering activity, number of missed letters, and letter reaction time were significantly higher for glaucoma patients than for control participants. In conclusion, glaucoma patients were able to avoid objects and maintain a nominal lane keeping performance, but applied more steering input than control participants, and were more likely than control participants to miss peripherally projected stimuli. The eye-tracking results suggest that glaucoma patients did not use extra visual search to compensate for their visual field loss. Limitations of the study, such as small sample size, are discussed. PMID:24146975

  19. Health motivation and product design determine consumers' visual attention to nutrition information on food products.

    PubMed

    Visschers, Vivianne H M; Hess, Rebecca; Siegrist, Michael

    2010-07-01

    In the present study we investigated consumers' visual attention to nutrition information on food products using an indirect instrument, an eye tracker. In addition, we looked at whether people with a health motivation focus on nutrition information on food products more than people with a taste motivation. Respondents were instructed to choose one of five cereals for either the kindergarten (health motivation) or the student cafeteria (taste motivation). The eye tracker measured their visual attention during this task. Then respondents completed a short questionnaire. Laboratory of the ETH Zurich, Switzerland. Videos and questionnaires from thirty-two students (seventeen males; mean age 24.91 years) were analysed. Respondents with a health motivation viewed the nutrition information on the food products for longer and more often than respondents with a taste motivation. Health motivation also seemed to stimulate deeper processing of the nutrition information. The student cafeteria group focused primarily on the other information and did this for longer and more often than the health motivation group. Additionally, the package design affected participants' nutrition information search. Two factors appear to influence whether people pay attention to nutrition information on food products: their motivation and the product's design. If the package design does not sufficiently facilitate the localization of nutrition information, health motivation can stimulate consumers to look for nutrition information so that they may make a more deliberate food choice.

  20. Always on My Mind? Recognition of Attractive Faces May Not Depend on Attention

    PubMed Central

    Silva, André; Macedo, António F.; Albuquerque, Pedro B.; Arantes, Joana

    2016-01-01

    Little research has examined what happens to attention and memory as a whole when humans see someone attractive. Hence, we investigated whether attractive stimuli gather more attention and are better remembered than unattractive stimuli. Participants took part in an attention task – in which matrices containing attractive and unattractive male naturalistic photographs were presented to 54 females, and measures of eye-gaze location and fixation duration using an eye-tracker were taken – followed by a recognition task. Eye-gaze was higher for the attractive stimuli compared to unattractive stimuli. Also, attractive photographs produced more hits and false recognitions than unattractive photographs which may indicate that regardless of attention allocation, attractive photographs produce more correct but also more false recognitions. We present an evolutionary explanation for this, as attending to more attractive faces but not always remembering them accurately and differentially compared with unseen attractive faces, may help females secure mates with higher reproductive value. PMID:26858683

  1. Assisting autistic children with wireless EOG technology.

    PubMed

    Rapela, Joaquin; Lin, Tsong-Yan; Westerfield, Marissa; Jung, Tzyy-Ping; Townsend, Jeanne

    2012-01-01

    We propose a novel intervention to train the speed and accuracy of attention orienting and eye movements in Autism Spectrum Disorder (ASD). Training eye movements and attention could not only affect those important functions directly, but could also result in broader improvement of social communication skills. To this end we describe a system that would allow ASD children to improve their fixation skills while playing a computer game controlled by an eye tracker. Because this intervention will probably be time consuming, this system should be designed to be used at homes. To make this possible, we propose an implementation based on wireless and dry electrooculography (EOG) technology. If successful, this system would develop an approach to therapy that would improve clinical and behavioral function in children and adults with ASD. As our initial steps in this direction, here we describe the design of a computer game to be used in this system, and the predictions of gaze position from EOG data recorded while a subject played this game.

  2. How do design features influence consumer attention when looking for nutritional information on food labels? Results from an eye-tracking study on pan bread labels.

    PubMed

    Antúnez, Lucía; Vidal, Leticia; Sapolinski, Alejandra; Giménez, Ana; Maiche, Alejandro; Ares, Gastón

    2013-08-01

    The aim of this work was to evaluate consumer visual processing of food labels when evaluating the salt content of pan bread labels and to study the influence of label design and nutritional labelling format on consumer attention. A total of 16 pan bread labels, designed according to a full factorial design, were presented to 52 participants, who were asked to decide whether the sodium content of each label was medium or low, while their eye movements were recorded using an eye tracker. Results showed that most participants looked at nutrition labels and the traffic light system to conclude on the salt content of the labels. However, the average percentage of participants who looked at the actual sodium content was much lower. Nutrition information format affected participants' processing of nutrition information. Among other effects, the inclusion of the traffic light system increased participants' attention towards some kind of nutrition information and facilitated its processing, but not its understanding.

  3. Death anxiety and visual oculomotor processing of arousing stimuli in a free view setting.

    PubMed

    Wendelberg, Linda; Volden, Frode; Yildirim-Yayilgan, Sule

    2017-04-01

    The main goal of this study was to determine how death anxiety (DA) affects visual processing when confronted with arousing stimuli. A total of 26 males and females were primed with either DA or a neutral primer and were given a free view/free choice task where eye movement was measured using an eye tracker. The goal was to identify measurable/observable indicators of whether the subjects were under the influence of DA during the free view. We conducted an eye tracking study because this is an area where we believe it is possible to find observable indicators. Ultimately, we observed some changes in the visual behavior, such as a prolonged average latency, altered sensitivity to the repetition of stimuli, longer fixations, less time in saccadic activity, and fewer classifications related to focal and ambient processing, which appear to occur under the influence of DA when the subjects are confronted with arousing stimuli. © 2017 Scandinavian Psychological Associations and John Wiley & Sons Ltd.

  4. Department of Defense In-House RDT&E Activities

    DTIC Science & Technology

    1981-10-30

    DISEASES*.’......*......... 43 MISSILE LABORATORY ................................................. 44 MOBILITY EQUIPMENT R&D COMMAND...HELICOPTER INFLIGHT MONITORING SYS WITH INSTRUMENTED RANGE; ANECHOIC AND REVERBERATION CHAMBERS; MOBILE -’ ACCOUSTICS LAB; EYE MOVEMENT MEASURING...IN- CLUDES: LIGHTWEIGIHT OPTICAL TRACKING SYSTEM, 25-TON CRANE, 2 20-TON MOBILE CRANES, 5-TON WRECKER, 40,000 LB ACFT LOADER, THREE T-28B ACFT, 1 UH

  5. Coordinated Control of Three-Dimensional Components of Smooth Pursuit to Rotating and Translating Textures.

    PubMed

    Edinger, Janick; Pai, Dinesh K; Spering, Miriam

    2017-01-01

    The neural control of pursuit eye movements to visual textures that simultaneously translate and rotate has largely been neglected. Here we propose that pursuit of such targets-texture pursuit-is a fully three-dimensional task that utilizes all three degrees of freedom of the eye, including torsion. Head-fixed healthy human adults (n = 8) tracked a translating and rotating random dot pattern, shown on a computer monitor, with their eyes. Horizontal, vertical, and torsional eye positions were recorded with a head-mounted eye tracker. The torsional component of pursuit is a function of the rotation of the texture, aligned with its visual properties. We observed distinct behaviors between those trials in which stimulus rotation was in the same direction as that of a rolling ball ("natural") in comparison to those with the opposite rotation ("unnatural"): Natural rotation enhanced and unnatural rotation reversed torsional velocity during pursuit, as compared to torsion triggered by a nonrotating random dot pattern. Natural rotation also triggered pursuit with a higher horizontal velocity gain and fewer and smaller corrective saccades. Furthermore, we show that horizontal corrective saccades are synchronized with torsional corrective saccades, indicating temporal coupling of horizontal and torsional saccade control. Pursuit eye movements have a torsional component that depends on the visual stimulus. Horizontal and torsional eye movements are separated in the motor periphery. Our findings suggest that translational and rotational motion signals might be coordinated in descending pursuit pathways.

  6. Towards free 3D end-point control for robotic-assisted human reaching using binocular eye tracking.

    PubMed

    Maimon-Dror, Roni O; Fernandez-Quesada, Jorge; Zito, Giuseppe A; Konnaris, Charalambos; Dziemian, Sabine; Faisal, A Aldo

    2017-07-01

    Eye-movements are the only directly observable behavioural signals that are highly correlated with actions at the task level, and proactive of body movements and thus reflect action intentions. Moreover, eye movements are preserved in many movement disorders leading to paralysis (or amputees) from stroke, spinal cord injury, Parkinson's disease, multiple sclerosis, and muscular dystrophy among others. Despite this benefit, eye tracking is not widely used as control interface for robotic interfaces in movement impaired patients due to poor human-robot interfaces. We demonstrate here how combining 3D gaze tracking using our GT3D binocular eye tracker with custom designed 3D head tracking system and calibration method enables continuous 3D end-point control of a robotic arm support system. The users can move their own hand to any location of the workspace by simple looking at the target and winking once. This purely eye tracking based system enables the end-user to retain free head movement and yet achieves high spatial end point accuracy in the order of 6 cm RMSE error in each dimension and standard deviation of 4 cm. 3D calibration is achieved by moving the robot along a 3 dimensional space filling Peano curve while the user is tracking it with their eyes. This results in a fully automated calibration procedure that yields several thousand calibration points versus standard approaches using a dozen points, resulting in beyond state-of-the-art 3D accuracy and precision.

  7. Direct Comparison of a Tablet Computer and a Personal Digital Assistant for Point-of-Care Documentation in Eye Care

    PubMed Central

    Silvey, Garry M.; Macri, Jennifer M.; Lee, Paul P.; Lobach, David F.

    2005-01-01

    New mobile computing devices including personal digital assistants (PDAs) and tablet computers have emerged to facilitate data collection at the point of care. Unfortunately, little research has been reported regarding which device is optimal for a given care setting. In this study we created and compared functionally identical applications on a Palm operating system-based PDA and a Windows-based tablet computer for point-of-care documentation of clinical observations by eye care professionals when caring for patients with diabetes. Eye-care professionals compared the devices through focus group sessions and through validated usability surveys. We found that the application on the tablet computer was preferred over the PDA for documenting the complex data related to eye care. Our findings suggest that the selection of a mobile computing platform depends on the amount and complexity of the data to be entered; the tablet computer functions better for high volume, complex data entry, and the PDA, for low volume, simple data entry. PMID:16779128

  8. Quantitative assessments of arousal by analyzing microsaccade rates and pupil fluctuations prior to slow eye movements.

    PubMed

    Honda, Shogo; Kohama, Takeshi; Tanaka, Tatsuro; Yoshida, Hisashi

    2014-01-01

    It is well known that a decline of arousal level causes of poor performance of movements or judgments. Our previous study indicates that microsaccade (MS) rates and pupil fluctuations change before slow eye movements (SEMs) (Honda et al. 2013). However, SEM detection of this study was obscure and insufficient. In this study, we propose a new SEM detection method and analyze MS rates and pupil fluctuations while subjects maintain their gaze on a target. We modified Shin et al.'s method, which is optimized for EOG (electrooculography) signals, to extract the period of sustaining SEMs using a general eye tracker. After SEM detection, we analyzed MS rates and pupil fluctuations prior to the initiation of SEMs. As a result, we were able to detect SEMs more precisely than in our previous study. Moreover, the results of eye movements and pupil fluctuations analyses show that gradual rise of MS rate and longitudinal miosis are observed prior to the initiation of SEMs, which is consistent with our previous study. These findings suggest that monitoring eye movements and pupil fluctuations may evaluate the arousal level more precisely. Further, we found that these tendencies become more significant when they are restricted to the initial SEMs.

  9. The Role of Retinal Imaging and Portable Screening Devices in Tele-ophthalmology Applications for Diabetic Retinopathy Management.

    PubMed

    DeBuc, Delia Cabrera

    2016-12-01

    In the years since its introduction, retinal imaging has transformed our capability to visualize the posterior pole of the eye. Increasing practical advances in mobile technology, regular monitoring, and population screening for diabetic retinopathy management offer the opportunity for further development of cost-effective applications through remote assessment of the diabetic eye using portable retinal cameras, smart-phone-based devices and telemedicine networks. Numerous retinal imaging methods and mobile technologies in tele-ophthalmology applications have been reported for diabetic retinopathy screening and management. They provide several advantages of automation, sensitivity, specificity, portability, and miniaturization for the development of point-of-care diagnostics for eye complications in diabetes. The aim of this paper is to review the role of retinal imaging and mobile technologies in tele-ophthalmology applications for diabetic retinopathy screening and management. At large, although improvements in current technology and telemedicine services are still needed, telemedicine has demonstrated to be a worthy tool to support health caregivers in the effective management and prevention of diabetes and its complications.

  10. [The cell phones as devices for the ocular fundus documentation].

    PubMed

    Němčanský, J; Kopecký, A; Timkovič, J; Mašek, P

    2014-12-01

    To present our experience with "smart phones" when examining and documenting human eyes. From September to October 2013 fifteen patients (8 men, 7 women) eye fundus was examined, an average age during the examination was 58 year (ranging from 20-65 years). The photo-documentation was performed with dilated pupils (tropicamid hydrochloridum 1% eye drops) with mobile phone Samsung Galaxy Nexus with the operating system Android 4.3 (Google Inc., Mountain View, CA, USA) and iPhone 4 with the operating system 7.0.4 (Apple Inc., Loop Cupertino, CA, USA), and with 20D lens (Volk Optical Inc., Mentor, OH, USA). The images of the retina taken with a mobile phone and the spherical lens are of a very good quality, precise and reproducible. Learning this technique is easy and fast, the learning curve is steep. Photo-documentation of retina with a mobile phone is a safe, time-saving, easy-to-learn technique, which may be used in a routine ophthalmologic practice. The main advantage of this technique is availability, small size and easy portability of the devices.

  11. A bill to modify the Department of Defense Program Guidance relating to the award of Post-Deployment/Mobilization Respite Absence administrative absence days to members of the reserve components to exempt any member whose qualified mobilization commenced before October 1, 2011, and continued on or after that date, from the changes to the program guidance that took effect on that date.

    THOMAS, 112th Congress

    Sen. Klobuchar, Amy [D-MN

    2012-02-16

    Senate - 02/16/2012 Read twice and referred to the Committee on Armed Services. (All Actions) Notes: For further action, see H.R.4045, which became Public Law 112-120 on 5/25/2012. Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  12. Validation of mobile eye-tracking as novel and efficient means for differentiating progressive supranuclear palsy from Parkinson's disease

    PubMed Central

    Marx, Svenja; Respondek, Gesine; Stamelou, Maria; Dowiasch, Stefan; Stoll, Josef; Bremmer, Frank; Oertel, Wolfgang H.; Höglinger, Günter U.; Einhäuser, Wolfgang

    2012-01-01

    Background: The decreased ability to carry out vertical saccades is a key symptom of Progressive Supranuclear Palsy (PSP). Objective measurement devices can help to reliably detect subtle eye movement disturbances to improve sensitivity and specificity of the clinical diagnosis. The present study aims at transferring findings from restricted stationary video-oculography (VOG) to a wearable head-mounted device, which can be readily applied in clinical practice. Methods: We investigated the eye movements in 10 possible or probable PSP patients, 11 Parkinson's disease (PD) patients, and 10 age-matched healthy controls (HCs) using a mobile, gaze-driven video camera setup (EyeSeeCam). Ocular movements were analyzed during a standardized fixation protocol and in an unrestricted real-life scenario while walking along a corridor. Results: The EyeSeeCam detected prominent impairment of both saccade velocity and amplitude in PSP patients, differentiating them from PD and HCs. Differences were particularly evident for saccades in the vertical plane, and stronger for saccades than for other eye movements. Differences were more pronounced during the standardized protocol than in the real-life scenario. Conclusions: Combined analysis of saccade velocity and saccade amplitude during the fixation protocol with the EyeSeeCam provides a simple, rapid (<20 s), and reliable tool to differentiate clinically established PSP patients from PD and HCs. As such, our findings prepare the ground for using wearable eye-tracking in patients with uncertain diagnoses. PMID:23248593

  13. The Reliability, Validity, and Normative Data of Interpupillary Distance and Pupil Diameter Using Eye-Tracking Technology

    PubMed Central

    Murray, Nicholas P.; Hunfalvay, Melissa; Bolte, Takumi

    2017-01-01

    Purpose The purpose of this study was to determine the reliability of interpupillary distance (IPD) and pupil diameter (PD) measures using an infrared eye tracker and central point stimuli. Validity of the test compared to known clinical tools was determined, and normative data was established against which individuals can measure themselves. Methods Participants (416) across various demographics were examined for normative data. Of these, 50 were examined for reliability and validity. Validity for IPD measured the test (RightEye IPD/PD) against the PL850 Pupilometer and the Essilor Digital CRP. For PD, the test was measured against the Rosenbaum Pocket Vision Screener (RPVS). Reliability was analyzed with intraclass correlation coefficients (ICC) between trials with Cronbach's alpha (CA) and the standard error of measurement for each ICC. Convergent validity was investigated by calculating the bivariate correlation coefficient. Results Reliability results were strong (CA > 0.7) for all measures. High positive significant correlations were found between the RightEye IPD test and the PL850 Pupilometer (P < 0.001) and Essilor Digital CRP (P < 0.001) and for the RightEye PD test and the RPVS (P < 0.001). Conclusions Using infrared eye tracking and the RightEye IPD/PD test stimuli, reliable and accurate measures of IPD and PD were found. Results from normative data showed an adequate comparison for people with normal vision development. Translational Relevance Results revealed a central point of fixation may remove variability in examining PD reliably using infrared eye tracking when consistent environmental and experimental procedures are conducted. PMID:28685104

  14. Dioptric defocus maps across the visual field for different indoor environments.

    PubMed

    García, Miguel García; Ohlendorf, Arne; Schaeffel, Frank; Wahl, Siegfried

    2018-01-01

    One of the factors proposed to regulate the eye growth is the error signal derived from the defocus in the retina and actually, this might arise from defocus not only in the fovea but the whole visual field. Therefore, myopia could be better predicted by spatio-temporally mapping the 'environmental defocus' over the visual field. At present, no devices are available that could provide this information. A 'Kinect sensor v1' camera (Microsoft Corp.) and a portable eye tracker were used for developing a system for quantifying 'indoor defocus error signals' across the central 58° of the visual field. Dioptric differences relative to the fovea (assumed to be in focus) were recorded over the visual field and 'defocus maps' were generated for various scenes and tasks.

  15. Technical Note: Mobile accelerator guidance using an optical tracker during docking in IOERT procedures.

    PubMed

    Marinetto, Eugenio; Victores, Juan González; García-Sevilla, Mónica; Muñoz, Mercedes; Calvo, Felipe Ángel; Balaguer, Carlos; Desco, Manuel; Pascau, Javier

    2017-10-01

    Intraoperative electron radiation therapy (IOERT) involves the delivery of a high radiation dose during tumor resection in a shorter time than other radiation techniques, thus improving local control of tumors. However, a linear accelerator device is needed to produce the beam safely. Mobile linear accelerators have been designed as dedicated units that can be moved into the operating room and deliver radiation in situ. Correct and safe dose delivery is a key concern when using mobile accelerators. The applicator is commonly fixed to the patient's bed to ensure that the dose is delivered to the prescribed location, and the mobile accelerator is moved to dock the applicator to the radiation beam output (gantry). In a typical clinical set-up, this task is time-consuming because of safety requirements and the limited degree of freedom of the gantry. The objective of this study was to present a navigation solution based on optical tracking for guidance of docking to improve safety and reduce procedure time. We used an optical tracker attached to the mobile linear accelerator to track the prescribed localization of the radiation collimator inside the operating room. Using this information, the integrated navigation system developed computes the movements that the mobile linear accelerator needs to perform to align the applicator and the radiation gantry and warns the physician if docking is unrealizable according to the available degrees of freedom of the mobile linear accelerator. Furthermore, we coded a software application that connects all the necessary functioning elements and provides a user interface for the system calibration and the docking guidance. The system could safeguard against the spatial limitations of the operating room, calculate the optimal arrangement of the accelerator and reduce the docking time in computer simulations and experimental setups. The system could be used to guide docking with any commercial linear accelerator. We believe that the docking navigator we present is a major contribution to IOERT, where docking is critical when attempting to reduce surgical time, ensure patient safety and guarantee that the treatment administered follows the radiation oncologist's prescription. © 2017 American Association of Physicists in Medicine.

  16. A new system for quantitative evaluation of infant gaze capabilities in a wide visual field.

    PubMed

    Pratesi, Andrea; Cecchi, Francesca; Beani, Elena; Sgandurra, Giuseppina; Cioni, Giovanni; Laschi, Cecilia; Dario, Paolo

    2015-09-07

    The visual assessment of infants poses specific challenges: many techniques that are used on adults are based on the patient's response, and are not suitable for infants. Significant advances in the eye-tracking have made this assessment of infant visual capabilities easier, however, eye-tracking still requires the subject's collaboration, in most cases and thus limiting the application in infant research. Moreover, there is a lack of transferability to clinical practice, and thus it emerges the need for a new tool to measure the paradigms and explore the most common visual competences in a wide visual field. This work presents the design, development and preliminary testing of a new system for measuring infant's gaze in the wide visual field called CareToy C: CareToy for Clinics. The system is based on a commercial eye tracker (SmartEye) with six cameras running at 60 Hz, suitable for measuring an infant's gaze. In order to stimulate the infant visually and audibly, a mechanical structure has been designed to support five speakers and five screens at a specific distance (60 cm) and angle: one in the centre, two on the right-hand side and two on the left (at 30° and 60° respectively). Different tasks have been designed in order to evaluate the system capability to assess the infant's gaze movements during different conditions (such as gap, overlap or audio-visual paradigms). Nine healthy infants aged 4-10 months were assessed as they performed the visual tasks at random. We developed a system able to measure infant's gaze in a wide visual field covering a total visual range of ±60° from the centre with an intermediate evaluation at ±30°. Moreover, the same system, thanks to different integrated software, was able to provide different visual paradigms (as gap, overlap and audio-visual) assessing and comparing different visual and multisensory sub-competencies. The proposed system endowed the integration of a commercial eye-tracker into a purposive setup in a smart and innovative way. The proposed system is suitable for measuring and evaluating infant's gaze capabilities in a wide visual field, in order to provide quantitative data that can enrich the clinical assessment.

  17. Navigation-synchronized multimodal control wheelchair from brain to alternative assistive technologies for persons with severe disabilities.

    PubMed

    Puanhvuan, Dilok; Khemmachotikun, Sarawin; Wechakarn, Pongsakorn; Wijarn, Boonyanuch; Wongsawat, Yodchanan

    2017-04-01

    Currently, electric wheelchairs are commonly used to improve mobility in disabled people. In severe cases, the user is unable to control the wheelchair by themselves because his/her motor functions are disabled. To restore mobility function, a brain-controlled wheelchair (BCW) would be a promising system that would allow the patient to control the wheelchair by their thoughts. P300 is a reliable brain electrical signal, a component of visual event-related potentials (ERPs), that could be used for interpreting user commands. This research aimed to propose a prototype BCW to allowed severe motor disabled patients to practically control a wheelchair for use in their home environment. The users were able to select from 9 possible destination commands in the automatic mode and from 4 directional commands (forward, backward, turn left and right) in the shared-control mode. These commands were selected via the designed P300 processing system. The wheelchair was steered to the desired location by the implemented navigation system. Safety of the user was ensured during wheelchair navigation due to the included obstacle detection and avoidance features. A combination of P300 and EOG was used as a hybrid BCW system. The user could fully operate the system such as enabling P300 detection system, mode shifting and stop/cancelation command by performing a different consecutive blinks to generate eye blinking patterns. The results revealed that the prototype BCW could be operated in either of the proposed modes. With the new design of the LED-based P300 stimulator, the average accuracies of the P300 detection algorithm in the shared-control and automatic modes were 95.31 and 83.42% with 3.09 and 3.79 bits/min, respectively. The P300 classification error was acceptable, as the user could cancel an incorrect command by blinking 2 times. Moreover, the proposed navigation system had a flexible design that could be interfaced with other assistive technologies. This research developed 3 alternative input modules: an eye tracker module and chin and hand controller modules. The user could select the most suitable assistive technology based on his/her level of disability. Other existing assistive technologies could also be connected to the proposed system in the future using the same protocol.

  18. Drowsy driver mobile application: Development of a novel scleral-area detection method.

    PubMed

    Mohammad, Faisal; Mahadas, Kausalendra; Hung, George K

    2017-10-01

    A reliable and practical app for mobile devices was developed to detect driver drowsiness. It consisted of two main components: a Haar cascade classifier, provided by a computer vision framework called OpenCV, for face/eye detection; and a dedicated JAVA software code for image processing that was applied over a masked region circumscribing the eye. A binary threshold was performed over the masked region to provide a quantitative measure of the number of white pixels in the sclera, which represented the state of eye opening. A continuously low white-pixel count would indicate drowsiness, thereby triggering an alarm to alert the driver. This system was successfully implemented on: (1) a static face image, (2) two subjects under laboratory conditions, and (3) a subject in a vehicle environment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Hand-eye calibration using a target registration error model.

    PubMed

    Chen, Elvis C S; Morgan, Isabella; Jayarathne, Uditha; Ma, Burton; Peters, Terry M

    2017-10-01

    Surgical cameras are prevalent in modern operating theatres and are often used as a surrogate for direct vision. Visualisation techniques (e.g. image fusion) made possible by tracking the camera require accurate hand-eye calibration between the camera and the tracking system. The authors introduce the concept of 'guided hand-eye calibration', where calibration measurements are facilitated by a target registration error (TRE) model. They formulate hand-eye calibration as a registration problem between homologous point-line pairs. For each measurement, the position of a monochromatic ball-tip stylus (a point) and its projection onto the image (a line) is recorded, and the TRE of the resulting calibration is predicted using a TRE model. The TRE model is then used to guide the placement of the calibration tool, so that the subsequent measurement minimises the predicted TRE. Assessing TRE after each measurement produces accurate calibration using a minimal number of measurements. As a proof of principle, they evaluated guided calibration using a webcam and an endoscopic camera. Their endoscopic camera results suggest that millimetre TRE is achievable when at least 15 measurements are acquired with the tracker sensor ∼80 cm away on the laparoscope handle for a target ∼20 cm away from the camera.

  20. Assessing visual attention using eye tracking sensors in intelligent cognitive therapies based on serious games.

    PubMed

    Frutos-Pascual, Maite; Garcia-Zapirain, Begonya

    2015-05-12

    This study examines the use of eye tracking sensors as a means to identify children's behavior in attention-enhancement therapies. For this purpose, a set of data collected from 32 children with different attention skills is analyzed during their interaction with a set of puzzle games. The authors of this study hypothesize that participants with better performance may have quantifiably different eye-movement patterns from users with poorer results. The use of eye trackers outside the research community may help to extend their potential with available intelligent therapies, bringing state-of-the-art technologies to users. The use of gaze data constitutes a new information source in intelligent therapies that may help to build new approaches that are fully-customized to final users' needs. This may be achieved by implementing machine learning algorithms for classification. The initial study of the dataset has proven a 0.88 (±0.11) classification accuracy with a random forest classifier, using cross-validation and hierarchical tree-based feature selection. Further approaches need to be examined in order to establish more detailed attention behaviors and patterns among children with and without attention problems.

  1. Assessing Visual Attention Using Eye Tracking Sensors in Intelligent Cognitive Therapies Based on Serious Games

    PubMed Central

    Frutos-Pascual, Maite; Garcia-Zapirain, Begonya

    2015-01-01

    This study examines the use of eye tracking sensors as a means to identify children's behavior in attention-enhancement therapies. For this purpose, a set of data collected from 32 children with different attention skills is analyzed during their interaction with a set of puzzle games. The authors of this study hypothesize that participants with better performance may have quantifiably different eye-movement patterns from users with poorer results. The use of eye trackers outside the research community may help to extend their potential with available intelligent therapies, bringing state-of-the-art technologies to users. The use of gaze data constitutes a new information source in intelligent therapies that may help to build new approaches that are fully-customized to final users' needs. This may be achieved by implementing machine learning algorithms for classification. The initial study of the dataset has proven a 0.88 (±0.11) classification accuracy with a random forest classifier, using cross-validation and hierarchical tree-based feature selection. Further approaches need to be examined in order to establish more detailed attention behaviors and patterns among children with and without attention problems. PMID:25985158

  2. Eye-tracking of visual attention in web-based assessment using the Force Concept Inventory

    NASA Astrophysics Data System (ADS)

    Han, Jing; Chen, Li; Fu, Zhao; Fritchman, Joseph; Bao, Lei

    2017-07-01

    This study used eye-tracking technology to investigate students’ visual attention while taking the Force Concept Inventory (FCI) in a web-based interface. Eighty nine university students were randomly selected into a pre-test group and a post-test group. Students took the 30-question FCI on a computer equipped with an eye-tracker. There were seven weeks of instruction between the pre- and post-test data collection. Students’ performance on the FCI improved significantly from pre-test to post-test. Meanwhile, the eye-tracking results reveal that the time students spent on taking the FCI test was not affected by student performance and did not change from pre-test to post-test. Analysis of students’ attention to answer choices shows that on the pre-test students primarily focused on the naïve choices and ignored the expert choices. On the post-test, although students had shifted their primary attention to the expert choices, they still kept a high level of attention to the naïve choices, indicating significant conceptual mixing and competition during problem solving. Outcomes of this study provide new insights on students’ conceptual development in learning physics.

  3. Etracker: A Mobile Gaze-Tracking System with Near-Eye Display Based on a Combined Gaze-Tracking Algorithm.

    PubMed

    Li, Bin; Fu, Hong; Wen, Desheng; Lo, WaiLun

    2018-05-19

    Eye tracking technology has become increasingly important for psychological analysis, medical diagnosis, driver assistance systems, and many other applications. Various gaze-tracking models have been established by previous researchers. However, there is currently no near-eye display system with accurate gaze-tracking performance and a convenient user experience. In this paper, we constructed a complete prototype of the mobile gaze-tracking system ' Etracker ' with a near-eye viewing device for human gaze tracking. We proposed a combined gaze-tracking algorithm. In this algorithm, the convolutional neural network is used to remove blinking images and predict coarse gaze position, and then a geometric model is defined for accurate human gaze tracking. Moreover, we proposed using the mean value of gazes to resolve pupil center changes caused by nystagmus in calibration algorithms, so that an individual user only needs to calibrate it the first time, which makes our system more convenient. The experiments on gaze data from 26 participants show that the eye center detection accuracy is 98% and Etracker can provide an average gaze accuracy of 0.53° at a rate of 30⁻60 Hz.

  4. Effect of a single session of transcranial direct-current stimulation combined with virtual reality training on the balance of children with cerebral palsy: a randomized, controlled, double-blind trial

    PubMed Central

    Lazzari, Roberta Delasta; Politti, Fabiano; Santos, Cibele Alimedia; Dumont, Arislander Jonathan Lopes; Rezende, Fernanda Lobo; Grecco, Luanda André Collange; Braun Ferreira, Luiz Alfredo; Oliveira, Claudia Santos

    2015-01-01

    [Purpose] The aim of the present study was to investigate the effects of a single session of transcranial direct current stimulation combined with virtual reality training on the balance of children with cerebral palsy. [Subjetcs and Methods] Children with cerebral palsy between four and 12 years of age were randomly allocated to two groups: an experimental group which performed a single session of mobility training with virtual reality combined with active transcranial direct current stimulation; and a control group which performed a single session of mobility training with virtual reality combined with placebo transcranial direct current stimulation. The children were evaluated before and after the training protocols. Static balance (sway area, displacement, velocity and frequency of oscillations of the center of pressure on the anteroposterior and mediolateral axes) was evaluated using a force plate under four conditions (30-second measurements for each condition): feet on the force plate with the eyes open, and with the eyes closed; feet on a foam mat with the eyes open, and with the eyes closed. [Results] An increase in sway velocity was the only significant difference found. [Conclusion] A single session of anodal transcranial direct current stimulation combined with mobility training elicited to lead to an increase in the body sway velocity of children with cerebral palsy. PMID:25931726

  5. Marine Corps Budgetary Reprogramming Effectiveness

    DTIC Science & Technology

    2015-03-01

    infrastructure (Appropriations Act of Congress, 2008). The environmental restoration is a transfer account controlled by the DOD. Usually in the case of...at an average just over 11 percent and the Marine Corps encircle the backend of the DOD portion of reprogramming with the Marine Corps reprogramming...blue force tracker (BFT), radio systems, high mobility multipurpose wheeled vehicle (HMMWV), medium tactical vehicle replacement (MTVR), and

  6. To require the Secretary of Homeland Security to conduct a program in the maritime environment for the mobile biometric identification of suspected individuals, including terrorists, to enhance border security.

    THOMAS, 111th Congress

    Rep. Bilirakis, Gus M. [R-FL-9

    2009-02-24

    House - 09/22/2009 Provisions of measure incorporated into Title XI, Section 1107 of H.R. 3619, as reported by the Committee on Transportation. (All Actions) Tracker: This bill has the status Passed HouseHere are the steps for Status of Legislation:

  7. The effect of foot plantar massage on balance and functional reach in patients with type II diabetes.

    PubMed

    Tütün Yümin, Eylem; Şimşek, Tülay Tarsuslu; Sertel, Meral; Ankaralı, Handan; Yumin, Murat

    2017-02-01

    The aim of this study was to investigate the effect of manual foot plantar massage (classic and friction massage) on functional mobility level, balance, and functional reach in patients with type II diabetes mellitus (T2 DM). A total of 38 subjects diagnosed with T2 DM were included in the study. A healthy control group could not be formed in this study. After the subjects' socio-demographic data were obtained, Timed Up & Go (TUG) Test, functional reach test (FRT), one-leg standing test with eyes open-closed, and Visual Analogue Scale (VAS) to measure foot pain intensity were performed. The results were also divided and assessed in three groups according to the ages of the individuals (40-54, 55-64, and 65 and over). As a result of statistical analysis, a difference was found in the values obtained from TUG, FRT, and one-leg standing test with eyes open and closed (p < 0.05). Following the massage, TUG values significantly decreased comparison with those before the massage, whereas the values of FRT and one-leg standing test with eyes open and closed significantly increased compared with those before the massage (p > 0.05). According to age groups, there were statistical differences (p < 0.05) between the TUG, one-leg standing test with eyes open and closed test values of the individuals before and after the massage. The results of our study indicated that application of plantar massage to patients with T2 DM caused an improvement in balance, functional mobility, and functional reach values. An increase in body balance and functional mobility may explain the improvement in TUG. Foot massage to be added to rehabilitation exercise programs of DM patients will be important in improving balance and mobility of patients.

  8. Pax6 localizes to chromatin-rich territories and displays a slow nuclear mobility altered by disease mutations.

    PubMed

    Elvenes, Julianne; Sjøttem, Eva; Holm, Turid; Bjørkøy, Geir; Johansen, Terje

    2010-12-01

    The transcription factor Pax6 is crucial for the embryogenesis of multiple organs, including the eyes, parts of the brain and the pancreas. Mutations in one allele of PAX6 lead to eye diseases including Peter's anomaly and aniridia. Here, we use fluorescence recovery after photobleaching to show that Pax6 and also other Pax family proteins display a strikingly low nuclear mobility compared to other transcriptional regulators. For Pax6, the slow mobility is largely due to the presence of two DNA-binding domains, but protein-protein interactions also contribute. Consistently, the subnuclear localization of Pax6 suggests that it interacts preferentially with chromatin-rich territories. Some aniridia-causing missense mutations in Pax6 have impaired DNA-binding affinity. Interestingly, when these mutants were analyzed by FRAP, they displayed a pronounced increased mobility compared to wild-type Pax6. Hence, our results support the conclusion that disease mutations result in proteins with impaired function because of altered DNA- and protein-interaction capabilities.

  9. Live Imaging of LysoTracker-Labelled Phagolysosomes Tracks Diurnal Phagocytosis of Photoreceptor Outer Segment Fragments in Rat RPE Tissue Ex Vivo.

    PubMed

    Mao, Yingyu; Finnemann, Silvia C

    2016-01-01

    Renewal of rod photoreceptor outer segments in the mammalian eye involves synchronized diurnal shedding after light onset of spent distal outer segment fragments (POS) linked to swift clearance of shed POS from the subretinal space by the adjacent retinal pigment epithelium (RPE). Engulfed POS phagosomes in RPE cells mature to acidified phagolysosomes, which accomplish enzymatic degradation of POS macromolecules. Here, we used an acidophilic fluorophore LysoTracker to label acidic organelles in freshly dissected, live rat RPE tissue flat mounts. We observed that all RPE cells imaged contained numerous acidified POS phagolysosomes whose abundance per cell was dramatically increased 2 h after light onset as compared to either 1 h before or 4 h after light onset. Lack of organelles of similar diameter (of 1-2 μm) in phagocytosis-defective mutant RCS rat RPE confirmed that LysoTracker live imaging detected POS phagolysosomes. Lack of increase in lysosomal membrane protein LAMP-1 in RPE/choroid during the diurnal phagocytic burst suggests that formation of POS phagolysosomes in RPE in situ may not involve extra lysosome membrane biogenesis. Taken together, we report a new imaging approach that directly detects POS phagosome acidification and allows rapid tracking and quantification of POS phagocytosis by live RPE -tissue ex situ.

  10. Eye Movements of Patients with Tunnel Vision while Walking

    PubMed Central

    Vargas-Martín, Fernando; Peli, Eli

    2006-01-01

    Purpose To determine how severe peripheral field loss (PFL) affects the dispersion of eye movements relative to the head, while walking in real environments. This information should help to better define the visual field and clearance requirements for head-mounted mobility visual aids. Methods Eye positions relative to the head were recorded in five retinitis pigmentosa patients with less than 15° of visual field and three normally-sighted people, each walking in varied environments for more than 30 minutes. The eye position recorder was made portable by modifying a head-mounted ISCAN system. Custom data processing was implemented to reject unreliable data. Sample standard deviations of eye position (dispersion) were compared across subject groups and environments. Results PFL patients exhibited narrower horizontal eye position dispersions than normally-sighted subjects (9.4° vs. 14.2°, p < 0.0001) and PFL patients’ vertical dispersions were smaller when walking indoors than outdoors (8.2° vs. 10.3°, p = 0.048). Conclusions When walking, the PFL patients did not increase their scanning eye movements to compensate for missing peripheral vision information. Their horizontal scanning was actually reduced, possibly because saccadic amplitude is limited by a lack of peripheral stimulation. The results suggest that a field-of-view as wide as 40° may be needed for closed (immersive) head-mounted mobility aids, while a much narrower display, perhaps as narrow as 20°, might be sufficient with an open design. PMID:17122116

  11. Eye movements of patients with tunnel vision while walking.

    PubMed

    Vargas-Martín, Fernando; Peli, Eli

    2006-12-01

    To determine how severe peripheral field loss (PFL) affects the dispersion of eye movements relative to the head in patients walking in real environments. This information should help to define the visual field and clearance requirements for head-mounted mobility visual aids. Eye positions relative to the head were recorded in five patients with retinitis pigmentosa who had less than 15 degrees of visual field and in three normally sighted people, each walking in varied environments for more than 30 minutes. The eye-position recorder was made portable by modifying a head-mounted system (ISCAN, Burlington, MA). Custom data processing was implemented, to reject unreliable data. Sample standard deviations of eye position (dispersion) were compared across subject groups and environments. The patients with PFL exhibited narrower horizontal eye-position dispersions than did the normally sighted subjects (9.4 degrees vs. 14.2 degrees , P < 0.0001), and the vertical dispersions of patients with PFL were smaller when they were walking indoors than when walking outdoors (8.2 degrees vs. 10.3 degrees ; P = 0.048). When walking, the patients with PFL did not increase their scanning eye movements to compensate for missing peripheral vision information. Their horizontal scanning was actually reduced, possibly because of lack of peripheral stimulation. The results suggest that a field of view as wide as 40 degrees may be needed for closed (immersive) head-mounted mobility aids, whereas a much narrower display, perhaps as narrow as 20 degrees , may be sufficient with an open design.

  12. Arthropod eyes: The early Cambrian fossil record and divergent evolution of visual systems.

    PubMed

    Strausfeld, Nicholas J; Ma, Xiaoya; Edgecombe, Gregory D; Fortey, Richard A; Land, Michael F; Liu, Yu; Cong, Peiyun; Hou, Xianguang

    2016-03-01

    Four types of eyes serve the visual neuropils of extant arthropods: compound retinas composed of adjacent facets; a visual surface populated by spaced eyelets; a smooth transparent cuticle providing inwardly directed lens cylinders; and single-lens eyes. The first type is a characteristic of pancrustaceans, the eyes of which comprise lenses arranged as hexagonal or rectilinear arrays, each lens crowning 8-9 photoreceptor neurons. Except for Scutigeromorpha, the second type typifies Myriapoda whose relatively large eyelets surmount numerous photoreceptive rhabdoms stacked together as tiers. Scutigeromorph eyes are facetted, each lens crowning some dozen photoreceptor neurons of a modified apposition-type eye. Extant chelicerate eyes are single-lensed except in xiphosurans, whose lateral eyes comprise a cuticle with a smooth outer surface and an inner one providing regular arrays of lens cylinders. This account discusses whether these disparate eye types speak for or against divergence from one ancestral eye type. Previous considerations of eye evolution, focusing on the eyes of trilobites and on facet proliferation in xiphosurans and myriapods, have proposed that the mode of development of eyes in those taxa is distinct from that of pancrustaceans and is the plesiomorphic condition from which facetted eyes have evolved. But the recent discovery of enormous regularly facetted compound eyes belonging to early Cambrian radiodontans suggests that high-resolution facetted eyes with superior optics may be the ground pattern organization for arthropods, predating the evolution of arthrodization and jointed post-protocerebral appendages. Here we provide evidence that compound eye organization in stem-group euarthropods of the Cambrian can be understood in terms of eye morphologies diverging from this ancestral radiodontan-type ground pattern. We show that in certain Cambrian groups apposition eyes relate to fixed or mobile eyestalks, whereas other groups reveal concomitant evolution of sessile eyes equipped with optics typical of extant xiphosurans. Observations of fossil material, including that of trilobites and eurypterids, support the proposition that the ancestral compound eye was the apposition type. Cambrian arthropods include possible precursors of mandibulate eyes. The latter are the modified compound eyes, now sessile, and their underlying optic lobes exemplified by scutigeromorph chilopods, and the mobile stalked compound eyes and more elaborate optic lobes typifying Pancrustacea. Radical divergence from an ancestral apposition type is demonstrated by the evolution of chelicerate eyes, from doublet sessile-eyed stem-group taxa to special apposition eyes of xiphosurans, the compound eyes of eurypterids, and single-lens eyes of arachnids. Different eye types are discussed with respect to possible modes of life of the extinct species that possessed them, comparing these to extant counterparts and the types of visual centers the eyes might have served. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Mobile, Multimodal, Label-Free Imaging Probe Analysis of Choroidal Oximetry and Retinal Hypoxia

    DTIC Science & Technology

    2017-12-01

    these same eye injuries. Primary blast-induced injury (PBI), which can occur in eyes that are not punctured or ruptured by the blast, is correlated ...optimization. (1A-F) The component of our PBI- devices, output pressure detection sensor, amplifier, and input pressure panel. (1G) Correlation between...by changing the setting of blast generator. (2A-B) Correlation between output pressure and blast time duration. (2C) After PBI- treatment, the eyes of

  14. 77 FR 65413 - Certain Cameras and Mobile Devices, Related Software and Firmware, and Components Thereof and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-26

    ... (202) 205-3065. Copies of non- confidential documents filed in connection with this investigation are... a complaint filed on behalf of HumanEyes Technologies, Ltd. of Jerusalem, Israel on March 28, 2012..., complainant HumanEyes Technologies filed an unopposed motion to terminate the investigation pursuant to...

  15. Surgical extraction of intraocular Parelaphostrongylus tenuis (Nematoda: Metastrongyloidea) in a horse

    USDA-ARS?s Scientific Manuscript database

    Case Description – A 4-year-old Hanoverian horse from Wisconsin presented for evaluation of a worm-like structure in the anterior chamber of the right eye. Clinical Findings – Ophthalmic examination of the right eye revealed a white, thin, mobile parasite, presumably a nematode, present in the ventr...

  16. Take a Stand for Standing

    ERIC Educational Resources Information Center

    Labandz, Stephenie

    2010-01-01

    As a school-based physical therapist, the author sees children with a wide variety of diagnoses affecting their mobility and motor function. Supported standing is an important part of the routines of those who are unable to stand independently due to issues affecting the neuromuscular system. Being eye-to-eye with their peers and interacting with…

  17. Improving College Students English Learning with Dr. Eye Android Mid

    ERIC Educational Resources Information Center

    Yang, Ju Yin; Che, Pei-Chun

    2015-01-01

    This paper investigates college students' English language learning through use of Dr. Eye Android handheld mobile Internet device (MID). Compared to related studies, students' English learning using MIDs has not been evaluated and fully understood in the field of higher education. Quantitatively, the researchers used TOEIC pretest and posttest to…

  18. Dioptric defocus maps across the visual field for different indoor environments

    PubMed Central

    García, Miguel García; Ohlendorf, Arne; Schaeffel, Frank; Wahl, Siegfried

    2017-01-01

    One of the factors proposed to regulate the eye growth is the error signal derived from the defocus in the retina and actually, this might arise from defocus not only in the fovea but the whole visual field. Therefore, myopia could be better predicted by spatio-temporally mapping the ‘environmental defocus’ over the visual field. At present, no devices are available that could provide this information. A ‘Kinect sensor v1’ camera (Microsoft Corp.) and a portable eye tracker were used for developing a system for quantifying ‘indoor defocus error signals’ across the central 58° of the visual field. Dioptric differences relative to the fovea (assumed to be in focus) were recorded over the visual field and ‘defocus maps’ were generated for various scenes and tasks. PMID:29359108

  19. The eye-tracking of social stimuli in patients with Rett syndrome and autism spectrum disorders: a pilot study.

    PubMed

    Schwartzman, José Salomão; Velloso, Renata de Lima; D'Antino, Maria Eloísa Famá; Santos, Silvana

    2015-05-01

    To compare visual fixation at social stimuli in Rett syndrome (RT) and autism spectrum disorders (ASD) patients. Visual fixation at social stimuli was analyzed in 14 RS female patients (age range 4-30 years), 11 ASD male patients (age range 4-20 years), and 17 children with typical development (TD). Patients were exposed to three different pictures (two of human faces and one with social and non-social stimuli) presented for 8 seconds each on the screen of a computer attached to an eye-tracker equipment. Percentage of visual fixation at social stimuli was significantly higher in the RS group compared to ASD and even to TD groups. Visual fixation at social stimuli seems to be one more endophenotype making RS to be very different from ASD.

  20. A Kinect-Based Real-Time Compressive Tracking Prototype System for Amphibious Spherical Robots

    PubMed Central

    Pan, Shaowu; Shi, Liwei; Guo, Shuxiang

    2015-01-01

    A visual tracking system is essential as a basis for visual servoing, autonomous navigation, path planning, robot-human interaction and other robotic functions. To execute various tasks in diverse and ever-changing environments, a mobile robot requires high levels of robustness, precision, environmental adaptability and real-time performance of the visual tracking system. In keeping with the application characteristics of our amphibious spherical robot, which was proposed for flexible and economical underwater exploration in 2012, an improved RGB-D visual tracking algorithm is proposed and implemented. Given the limited power source and computational capabilities of mobile robots, compressive tracking (CT), which is the effective and efficient algorithm that was proposed in 2012, was selected as the basis of the proposed algorithm to process colour images. A Kalman filter with a second-order motion model was implemented to predict the state of the target and select candidate patches or samples for the CT tracker. In addition, a variance ratio features shift (VR-V) tracker with a Kalman estimation mechanism was used to process depth images. Using a feedback strategy, the depth tracking results were used to assist the CT tracker in updating classifier parameters at an adaptive rate. In this way, most of the deficiencies of CT, including drift and poor robustness to occlusion and high-speed target motion, were partly solved. To evaluate the proposed algorithm, a Microsoft Kinect sensor, which combines colour and infrared depth cameras, was adopted for use in a prototype of the robotic tracking system. The experimental results with various image sequences demonstrated the effectiveness, robustness and real-time performance of the tracking system. PMID:25856331

  1. A Kinect-based real-time compressive tracking prototype system for amphibious spherical robots.

    PubMed

    Pan, Shaowu; Shi, Liwei; Guo, Shuxiang

    2015-04-08

    A visual tracking system is essential as a basis for visual servoing, autonomous navigation, path planning, robot-human interaction and other robotic functions. To execute various tasks in diverse and ever-changing environments, a mobile robot requires high levels of robustness, precision, environmental adaptability and real-time performance of the visual tracking system. In keeping with the application characteristics of our amphibious spherical robot, which was proposed for flexible and economical underwater exploration in 2012, an improved RGB-D visual tracking algorithm is proposed and implemented. Given the limited power source and computational capabilities of mobile robots, compressive tracking (CT), which is the effective and efficient algorithm that was proposed in 2012, was selected as the basis of the proposed algorithm to process colour images. A Kalman filter with a second-order motion model was implemented to predict the state of the target and select candidate patches or samples for the CT tracker. In addition, a variance ratio features shift (VR-V) tracker with a Kalman estimation mechanism was used to process depth images. Using a feedback strategy, the depth tracking results were used to assist the CT tracker in updating classifier parameters at an adaptive rate. In this way, most of the deficiencies of CT, including drift and poor robustness to occlusion and high-speed target motion, were partly solved. To evaluate the proposed algorithm, a Microsoft Kinect sensor, which combines colour and infrared depth cameras, was adopted for use in a prototype of the robotic tracking system. The experimental results with various image sequences demonstrated the effectiveness, robustness and real-time performance of the tracking system.

  2. Investigating the Association of Eye Gaze Pattern and Diagnostic Error in Mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Voisin, Sophie; Pinto, Frank M; Xu, Songhua

    2013-01-01

    The objective of this study was to investigate the association between eye-gaze patterns and the diagnostic accuracy of radiologists for the task of assessing the likelihood of malignancy of mammographic masses. Six radiologists (2 expert breast imagers and 4 Radiology residents of variable training) assessed the likelihood of malignancy of 40 biopsy-proven mammographic masses (20 malignant and 20 benign) on a computer monitor. Eye-gaze data were collected using a commercial remote eye-tracker. Upon reviewing each mass, the radiologists were also asked to provide their assessment regarding the probability of malignancy of the depicted mass as well as a rating regardingmore » the perceived difficulty of the diagnostic task. The collected data were analyzed using established algorithms and various quantitative metrics were extracted to characterize the recorded gaze patterns. The extracted metrics were correlated with the radiologists diagnostic decisions and perceived complexity scores. Results showed that the visual gaze pattern of radiologists varies substantially, not only depending on their experience level but also among individuals. However, some eye gaze metrics appear to correlate with diagnostic error and perceived complexity more consistently. These results suggest that although gaze patterns are generally associated with diagnostic error and the human perceived difficulty of the diagnostic task, there are substantially individual differences that are not explained simply by the experience level of the individual performing the diagnostic task.« less

  3. Sophie in the Snow: A Simple Approach to Datalogging and Modelling in Physics

    ERIC Educational Resources Information Center

    Oldknow, Adrian; Huyton, Pip; Galloway, Ian

    2010-01-01

    Most students now have access to devices such as digital cameras and mobile phones that are capable of taking short video clips outdoors. Such clips can be used with powerful ICT tools, such as Tracker, Excel and TI-Nspire, to extract time and coordinate data about a moving object, to produce scattergrams and to fit models. In this article we…

  4. To require the Secretary of Homeland Security to conduct a program in the maritime environment for the mobile biometric identification of suspected individuals, including terrorists, to enhance border security.

    THOMAS, 111th Congress

    Rep. Bilirakis, Gus M. [R-FL-9

    2009-01-28

    10/23/2009 For Further Action See H.R.3619. (All Actions) Notes: For further action, see H.R.3619, which became Public Law 111-281 on 10/15/2010. Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  5. Quantitative posturography in altered sensory conditions: a way to assess balance instability in patients with chronic whiplash injury.

    PubMed

    Madeleine, Pascal; Prietzel, Hanne; Svarrer, Heine; Arendt-Nielsen, Lars

    2004-03-01

    To quantify neck mobility and posture with and without various postural perturbations. A multivariable 2-group study with repeated measures and treatments. A human performance laboratory. Eleven patients with chronic whiplash injury (mean age, 33.3+/-6.7 y; weight, 73.4+/-11.4 kg; height, 173.3+/-7.2 cm) with a sex- and age-matched control group (mean age, 33.1+/-6.8 y; weight, 68+/-12.5 kg; height, 171.5+/-6.3 cm). Neck mobility and the effects of postural perturbations affecting the visual, vestibular, cutaneous, proprioceptive, and nociceptive systems were measured. Active range of motion, neck position sense, and postural activity. We found significantly reduced neck mobility and increased postural activity in the patient group compared with the control group. In patients, there was significantly greater postural activity with eyes closed, eyes open and speaking, and eyes closed with Achilles' tendons vibrations compared with eyes open with no vibrations. In the controls, there was no significant effect of experimental muscle pain on postural activity. Patients with chronic whiplash injury had a protective response to neck movement and different tuning, sequencing, and execution of the postural synergies probably because of excessive reliance on visual input despite a possible deficit and altered vestibular and/or proprioceptive activity. In healthy volunteers, the pain induced by a single bolus injection of hypertonic saline was probably too limited in intensity and spreading to decrease postural stability.

  6. Fuzzy System-Based Target Selection for a NIR Camera-Based Gaze Tracker

    PubMed Central

    Naqvi, Rizwan Ali; Arsalan, Muhammad; Park, Kang Ryoung

    2017-01-01

    Gaze-based interaction (GBI) techniques have been a popular subject of research in the last few decades. Among other applications, GBI can be used by persons with disabilities to perform everyday tasks, as a game interface, and can play a pivotal role in the human computer interface (HCI) field. While gaze tracking systems have shown high accuracy in GBI, detecting a user’s gaze for target selection is a challenging problem that needs to be considered while using a gaze detection system. Past research has used the blinking of the eyes for this purpose as well as dwell time-based methods, but these techniques are either inconvenient for the user or requires a long time for target selection. Therefore, in this paper, we propose a method for fuzzy system-based target selection for near-infrared (NIR) camera-based gaze trackers. The results of experiments performed in addition to tests of the usability and on-screen keyboard use of the proposed method show that it is better than previous methods. PMID:28420114

  7. Through Their Eyes: Tracking the Gaze of Students in a Geology Field Course

    ERIC Educational Resources Information Center

    Maltese, Adam V.; Balliet, Russell N.; Riggs, Eric M.

    2013-01-01

    The focus of this research was to investigate how students learn to do fieldwork through observation. This study addressed the following questions: (1) Can mobile eye-tracking devices provide a robust source of data to investigate the observations and workflow of novice students while participating in a field exercise? If so, what are the…

  8. How directional mobility affects coexistence in rock-paper-scissors models

    NASA Astrophysics Data System (ADS)

    Avelino, P. P.; Bazeia, D.; Losano, L.; Menezes, J.; de Oliveira, B. F.; Santos, M. A.

    2018-03-01

    This work deals with a system of three distinct species that changes in time under the presence of mobility, selection, and reproduction, as in the popular rock-paper-scissors game. The novelty of the current study is the modification of the mobility rule to the case of directional mobility, in which the species move following the direction associated to a larger (averaged) number density of selection targets in the surrounding neighborhood. Directional mobility can be used to simulate eyes that see or a nose that smells, and we show how it may contribute to reduce the probability of coexistence.

  9. How directional mobility affects coexistence in rock-paper-scissors models.

    PubMed

    Avelino, P P; Bazeia, D; Losano, L; Menezes, J; de Oliveira, B F; Santos, M A

    2018-03-01

    This work deals with a system of three distinct species that changes in time under the presence of mobility, selection, and reproduction, as in the popular rock-paper-scissors game. The novelty of the current study is the modification of the mobility rule to the case of directional mobility, in which the species move following the direction associated to a larger (averaged) number density of selection targets in the surrounding neighborhood. Directional mobility can be used to simulate eyes that see or a nose that smells, and we show how it may contribute to reduce the probability of coexistence.

  10. Visual Contrast Sensitivity in Early-Stage Parkinson's Disease.

    PubMed

    Ming, Wendy; Palidis, Dimitrios J; Spering, Miriam; McKeown, Martin J

    2016-10-01

    Visual impairments are frequent in Parkinson's disease (PD) and impact normal functioning in daily activities. Visual contrast sensitivity is a powerful nonmotor sign for discriminating PD patients from controls. However, it is usually assessed with static visual stimuli. Here we examined the interaction between perception and eye movements in static and dynamic contrast sensitivity tasks in a cohort of mildly impaired, early-stage PD patients. Patients (n = 13) and healthy age-matched controls (n = 12) viewed stimuli of various spatial frequencies (0-8 cyc/deg) and speeds (0°/s, 10°/s, 30°/s) on a computer monitor. Detection thresholds were determined by asking participants to adjust luminance contrast until they could just barely see the stimulus. Eye position was recorded with a video-based eye tracker. Patients' static contrast sensitivity was impaired in the intermediate spatial-frequency range and this impairment correlated with fixational instability. However, dynamic contrast sensitivity and patients' smooth pursuit were relatively normal. An independent component analysis revealed contrast sensitivity profiles differentiating patients and controls. Our study simultaneously assesses perceptual contrast sensitivity and eye movements in PD, revealing a possible link between fixational instability and perceptual deficits. Spatiotemporal contrast sensitivity profiles may represent an easily measurable metric as a component of a broader combined biometric for nonmotor features observed in PD.

  11. Hand–eye calibration using a target registration error model

    PubMed Central

    Morgan, Isabella; Jayarathne, Uditha; Ma, Burton; Peters, Terry M.

    2017-01-01

    Surgical cameras are prevalent in modern operating theatres and are often used as a surrogate for direct vision. Visualisation techniques (e.g. image fusion) made possible by tracking the camera require accurate hand–eye calibration between the camera and the tracking system. The authors introduce the concept of ‘guided hand–eye calibration’, where calibration measurements are facilitated by a target registration error (TRE) model. They formulate hand–eye calibration as a registration problem between homologous point–line pairs. For each measurement, the position of a monochromatic ball-tip stylus (a point) and its projection onto the image (a line) is recorded, and the TRE of the resulting calibration is predicted using a TRE model. The TRE model is then used to guide the placement of the calibration tool, so that the subsequent measurement minimises the predicted TRE. Assessing TRE after each measurement produces accurate calibration using a minimal number of measurements. As a proof of principle, they evaluated guided calibration using a webcam and an endoscopic camera. Their endoscopic camera results suggest that millimetre TRE is achievable when at least 15 measurements are acquired with the tracker sensor ∼80 cm away on the laparoscope handle for a target ∼20 cm away from the camera. PMID:29184657

  12. Biracial and monoracial infant own-race face perception: an eye tracking study.

    PubMed

    Gaither, Sarah E; Pauker, Kristin; Johnson, Scott P

    2012-11-01

    We know that early experience plays a crucial role in the development of face processing, but we know little about how infants learn to distinguish faces from different races, especially for non-Caucasian populations. Moreover, it is unknown whether differential processing of different race faces observed in typically studied monoracial infants extends to biracial infants as well. Thus, we investigated 3-month-old Caucasian, Asian and biracial (Caucasian-Asian) infants' ability to distinguish Caucasian and Asian faces. Infants completed two within-subject, infant-controlled habituation sequences and test trials as an eye tracker recorded looking times and scanning patterns. Examination of individual differences revealed significant positive correlations between own-race novelty preference and scanning frequency between eye and mouth regions of own-race habituation stimuli for Caucasian and Asian infants, suggesting that facility in own-race face discrimination stems from active inspection of internal facial features in these groups. Biracial infants, however, showed the opposite effect: An 'own-race' novelty preference was associated with reduced scanning between eye and mouth regions of 'own-race' habituation stimuli, suggesting that biracial infants use a distinct approach to processing frequently encountered faces. Future directions for investigating face processing development in biracial populations are discussed. © 2012 Blackwell Publishing Ltd.

  13. Biracial and Monoracial Infant Own-Race Face Perception: An Eye Tracking Study

    PubMed Central

    Gaither, Sarah E.; Pauker, Kristin; Johnson, Scott P.

    2012-01-01

    We know early experience plays a crucial role in the development of face processing, but we know little about how infants learn to distinguish faces from different races, especially for non-Caucasian populations. Moreover, it is unknown whether differential processing of different race faces observed in typically-studied monoracial infants extends to biracial infants as well. Thus, we investigated 3-month-old Caucasian, Asian and biracial (Caucasian-Asian) infants’ ability to distinguish Caucasian and Asian faces. Infants completed two within-subject, infant-controlled habituation sequences and test trials as an eye tracker recorded looking times and scanning patterns. Examination of individual differences revealed significant positive correlations between own-race novelty preference and scanning frequency between eye and mouth regions of own-race habituation stimuli for Caucasian and Asian infants, suggesting that facility in own-race face discrimination stems from active inspection of internal facial features in these groups. Biracial infants, however, showed the opposite effect: An “own-race” novelty preference was associated with reduced scanning between eye and mouth regions of “own-race” habituation stimuli, suggesting that biracial infants use a distinct approach to processing frequently encountered faces. Future directions for investigating face processing development in biracial populations are discussed. PMID:23106731

  14. Fixation-related FMRI analysis in the domain of reading research: using self-paced eye movements as markers for hemodynamic brain responses during visual letter string processing.

    PubMed

    Richlan, Fabio; Gagl, Benjamin; Hawelka, Stefan; Braun, Mario; Schurz, Matthias; Kronbichler, Martin; Hutzler, Florian

    2014-10-01

    The present study investigated the feasibility of using self-paced eye movements during reading (measured by an eye tracker) as markers for calculating hemodynamic brain responses measured by functional magnetic resonance imaging (fMRI). Specifically, we were interested in whether the fixation-related fMRI analysis approach was sensitive enough to detect activation differences between reading material (words and pseudowords) and nonreading material (line and unfamiliar Hebrew strings). Reliable reading-related activation was identified in left hemisphere superior temporal, middle temporal, and occipito-temporal regions including the visual word form area (VWFA). The results of the present study are encouraging insofar as fixation-related analysis could be used in future fMRI studies to clarify some of the inconsistent findings in the literature regarding the VWFA. Our study is the first step in investigating specific visual word recognition processes during self-paced natural sentence reading via simultaneous eye tracking and fMRI, thus aiming at an ecologically valid measurement of reading processes. We provided the proof of concept and methodological framework for the analysis of fixation-related fMRI activation in the domain of reading research. © The Author 2013. Published by Oxford University Press.

  15. Rett syndrome: basic features of visual processing-a pilot study of eye-tracking.

    PubMed

    Djukic, Aleksandra; Valicenti McDermott, Maria; Mavrommatis, Kathleen; Martins, Cristina L

    2012-07-01

    Consistently observed "strong eye gaze" has not been validated as a means of communication in girls with Rett syndrome, ubiquitously affected by apraxia, unable to reply either verbally or manually to questions during formal psychologic assessment. We examined nonverbal cognitive abilities and basic features of visual processing (visual discrimination attention/memory) by analyzing patterns of visual fixation in 44 girls with Rett syndrome, compared with typical control subjects. To determine features of visual fixation patterns, multiple pictures (with the location of the salient and presence/absence of novel stimuli as variables) were presented on the screen of a TS120 eye-tracker. Of the 44, 35 (80%) calibrated and exhibited meaningful patterns of visual fixation. They looked longer at salient stimuli (cartoon, 2.8 ± 2 seconds S.D., vs shape, 0.9 ± 1.2 seconds S.D.; P = 0.02), regardless of their position on the screen. They recognized novel stimuli, decreasing the fixation time on the central image when another image appeared on the periphery of the slide (2.7 ± 1 seconds S.D. vs 1.8 ± 1 seconds S.D., P = 0.002). Eye-tracking provides a feasible method for cognitive assessment and new insights into the "hidden" abilities of individuals with Rett syndrome. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Acceptance of Commercially Available Wearable Activity Trackers Among Adults Aged Over 50 and With Chronic Illness: A Mixed-Methods Evaluation.

    PubMed

    Mercer, Kathryn; Giangregorio, Lora; Schneider, Eric; Chilana, Parmit; Li, Melissa; Grindrod, Kelly

    2016-01-27

    Physical inactivity and sedentary behavior increase the risk of chronic illness and death. The newest generation of "wearable" activity trackers offers potential as a multifaceted intervention to help people become more active. To examine the usability and usefulness of wearable activity trackers for older adults living with chronic illness. We recruited a purposive sample of 32 participants over the age of 50, who had been previously diagnosed with a chronic illness, including vascular disease, diabetes, arthritis, and osteoporosis. Participants were between 52 and 84 years of age (mean 64); among the study participants, 23 (72%) were women and the mean body mass index was 31 kg/m(2). Participants tested 5 trackers, including a simple pedometer (Sportline or Mio) followed by 4 wearable activity trackers (Fitbit Zip, Misfit Shine, Jawbone Up 24, and Withings Pulse) in random order. Selected devices represented the range of wearable products and features available on the Canadian market in 2014. Participants wore each device for at least 3 days and evaluated it using a questionnaire developed from the Technology Acceptance Model. We used focus groups to explore participant experiences and a thematic analysis approach to data collection and analysis. Our study resulted in 4 themes: (1) adoption within a comfort zone; (2) self-awareness and goal setting; (3) purposes of data tracking; and (4) future of wearable activity trackers as health care devices. Prior to enrolling, few participants were aware of wearable activity trackers. Most also had been asked by a physician to exercise more and cited this as a motivation for testing the devices. None of the participants planned to purchase the simple pedometer after the study, citing poor accuracy and data loss, whereas 73% (N=32) planned to purchase a wearable activity tracker. Preferences varied but 50% felt they would buy a Fitbit and 42% felt they would buy a Misfit, Jawbone, or Withings. The simple pedometer had a mean acceptance score of 56/95 compared with 63 for the Withings, 65 for the Misfit and Jawbone, and 68 for the Fitbit. To improve usability, older users may benefit from devices that have better compatibility with personal computers or less-expensive Android mobile phones and tablets, and have comprehensive paper-based user manuals and apps that interpret user data. For older adults living with chronic illness, wearable activity trackers are perceived as useful and acceptable. New users may need support to both set up the device and learn how to interpret their data.

  17. Acceptance of Commercially Available Wearable Activity Trackers Among Adults Aged Over 50 and With Chronic Illness: A Mixed-Methods Evaluation

    PubMed Central

    Mercer, Kathryn; Giangregorio, Lora; Schneider, Eric; Chilana, Parmit; Li, Melissa

    2016-01-01

    Background Physical inactivity and sedentary behavior increase the risk of chronic illness and death. The newest generation of “wearable” activity trackers offers potential as a multifaceted intervention to help people become more active. Objective To examine the usability and usefulness of wearable activity trackers for older adults living with chronic illness. Methods We recruited a purposive sample of 32 participants over the age of 50, who had been previously diagnosed with a chronic illness, including vascular disease, diabetes, arthritis, and osteoporosis. Participants were between 52 and 84 years of age (mean 64); among the study participants, 23 (72%) were women and the mean body mass index was 31 kg/m2. Participants tested 5 trackers, including a simple pedometer (Sportline or Mio) followed by 4 wearable activity trackers (Fitbit Zip, Misfit Shine, Jawbone Up 24, and Withings Pulse) in random order. Selected devices represented the range of wearable products and features available on the Canadian market in 2014. Participants wore each device for at least 3 days and evaluated it using a questionnaire developed from the Technology Acceptance Model. We used focus groups to explore participant experiences and a thematic analysis approach to data collection and analysis. Results Our study resulted in 4 themes: (1) adoption within a comfort zone; (2) self-awareness and goal setting; (3) purposes of data tracking; and (4) future of wearable activity trackers as health care devices. Prior to enrolling, few participants were aware of wearable activity trackers. Most also had been asked by a physician to exercise more and cited this as a motivation for testing the devices. None of the participants planned to purchase the simple pedometer after the study, citing poor accuracy and data loss, whereas 73% (N=32) planned to purchase a wearable activity tracker. Preferences varied but 50% felt they would buy a Fitbit and 42% felt they would buy a Misfit, Jawbone, or Withings. The simple pedometer had a mean acceptance score of 56/95 compared with 63 for the Withings, 65 for the Misfit and Jawbone, and 68 for the Fitbit. To improve usability, older users may benefit from devices that have better compatibility with personal computers or less-expensive Android mobile phones and tablets, and have comprehensive paper-based user manuals and apps that interpret user data. Conclusions For older adults living with chronic illness, wearable activity trackers are perceived as useful and acceptable. New users may need support to both set up the device and learn how to interpret their data. PMID:26818775

  18. 75 FR 32809 - 30-Day Notice of Submission to the Office of Management and Budget (OMB); Opportunity for Public...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-09

    ...: Dr. James Gramann, NPS Social Science Division, 1201 ``Eye'' St., Washington, DC 20005; or via phone... Defenders of Wildlife and the Center for Biological Diversity, along with the Assateague Mobil Sport... Assateague Mobil Sport Fishermen Association did provide additional feedback, including recommendations for...

  19. No short-term effects of digital mobile radio telephone on the awake human electroencephalogram

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roeschke, J.; Mann, K.

    1997-05-01

    A recent study reported the results of an exploratory study of alterations of the quantitative sleep profile due to the effects of a digital mobile radio telephone. Rapid eye movement (REM) was suppressed, and the spectral power density in the 8--13 Hz frequency range during REM sleep was altered. The aim of the present study was to illuminate the influence of digital mobile radio telephone on the awake electroencephalogram (EEG) of healthy subjects. For this purpose, the authors investigated 34 male subjects in a single-blind cross-over design experiment by measuring spontaneous EEGs under closed-eyes condition from scalp positions C{sub 3}more » and C{sub 4} and comparing the effects of an active and an inactive digital mobile radio telephone (GSM) system. During exposure of nearly 3.5 min to the 900 MHz electromagnetic field pulsed at a frequency of 217 Hz and with a pulse width of 580 {micro}s, the authors could not detect any difference in the awake EEGs in terms of spectral power density measures.« less

  20. The Evaluation of HOMER as a Marine Corps Expeditionary Energy Predeployment Tool

    DTIC Science & Technology

    2010-09-01

    experiment was used to ensure the HOMER models were accurate. Following the calibration, the concept of expeditionary energy density as it pertains to power ...Brigade–Afghanistan xvi MEP Mobile Electric Power MPP Maximum Power Point MPPT Maximum Power Point Tracker NASA National Aeronautics and...process was used to analyze HOMER’s modeling capability: • Conduct photovoltaic (PV) experiment, • Develop a calibration process to match the HOMER

  1. The Evaluation of HOMER as a Marine Corps Expeditionary Energy Pre-deployment Tool

    DTIC Science & Technology

    2010-11-21

    used to ensure the HOMER models were accurate. Following the calibration, the concept of expeditionary energy density as it pertains to power ...MEP Mobile Electric Power MPP Maximum Power Point MPPT Maximum Power Point Tracker NASA National Aeronautics and Space Administration...process was used to analyze HOMER’s modeling capability: • Conduct photovoltaic (PV) experiment, • Develop a calibration process to match the HOMER

  2. Adults Scan Own- and Other-Race Faces Differently

    PubMed Central

    Fu, Genyue; Hu, Chao S.; Wang, Qiandong; Quinn, Paul C.; Lee, Kang

    2012-01-01

    It is well established that individuals show an other-race effect (ORE) in face recognition: they recognize own-race faces better than other-race faces. The present study tested the hypothesis that individuals would also scan own- and other-race faces differently. We asked Chinese participants to remember Chinese and Caucasian faces and we tested their memory of the faces over five testing blocks. The participants' eye movements were recorded with the use of an eye tracker. The data were analyzed with an Area of Interest approach using the key AOIs of a face (eyes, nose, and mouth). Also, we used the iMap toolbox to analyze the raw data of participants' fixation on each pixel of the entire face. Results from both types of analyses strongly supported the hypothesis. When viewing target Chinese or Caucasian faces, Chinese participants spent a significantly greater proportion of fixation time on the eyes of other-race Caucasian faces than the eyes of own-race Chinese faces. In contrast, they spent a significantly greater proportion of fixation time on the nose and mouth of Chinese faces than the nose and mouth of Caucasian faces. This pattern of differential fixation, for own- and other-race eyes and nose in particular, was consistent even as participants became increasingly familiar with the target faces of both races. The results could not be explained by the perceptual salience of the Chinese nose or Caucasian eyes because these features were not differentially salient across the races. Our results are discussed in terms of the facial morphological differences between Chinese and Caucasian faces and the enculturation of mutual gaze norms in East Asian cultures. PMID:22675486

  3. Adults scan own- and other-race faces differently.

    PubMed

    Fu, Genyue; Hu, Chao S; Wang, Qiandong; Quinn, Paul C; Lee, Kang

    2012-01-01

    It is well established that individuals show an other-race effect (ORE) in face recognition: they recognize own-race faces better than other-race faces. The present study tested the hypothesis that individuals would also scan own- and other-race faces differently. We asked Chinese participants to remember Chinese and Caucasian faces and we tested their memory of the faces over five testing blocks. The participants' eye movements were recorded with the use of an eye tracker. The data were analyzed with an Area of Interest approach using the key AOIs of a face (eyes, nose, and mouth). Also, we used the iMap toolbox to analyze the raw data of participants' fixation on each pixel of the entire face. Results from both types of analyses strongly supported the hypothesis. When viewing target Chinese or Caucasian faces, Chinese participants spent a significantly greater proportion of fixation time on the eyes of other-race Caucasian faces than the eyes of own-race Chinese faces. In contrast, they spent a significantly greater proportion of fixation time on the nose and mouth of Chinese faces than the nose and mouth of Caucasian faces. This pattern of differential fixation, for own- and other-race eyes and nose in particular, was consistent even as participants became increasingly familiar with the target faces of both races. The results could not be explained by the perceptual salience of the Chinese nose or Caucasian eyes because these features were not differentially salient across the races. Our results are discussed in terms of the facial morphological differences between Chinese and Caucasian faces and the enculturation of mutual gaze norms in East Asian cultures.

  4. Eliciting nicotine craving with virtual smoking cues.

    PubMed

    Gamito, Pedro; Oliveira, Jorge; Baptista, André; Morais, Diogo; Lopes, Paulo; Rosa, Pedro; Santos, Nuno; Brito, Rodrigo

    2014-08-01

    Craving is a strong desire to consume that emerges in every case of substance addiction. Previous studies have shown that eliciting craving with an exposure cues protocol can be a useful option for the treatment of nicotine dependence. Thus, the main goal of this study was to develop a virtual platform in order to induce craving in smokers. Fifty-five undergraduate students were randomly assigned to two different virtual environments: high arousal contextual cues and low arousal contextual cues scenarios (17 smokers with low nicotine dependency were excluded). An eye-tracker system was used to evaluate attention toward these cues. Eye fixation on smoking-related cues differed between smokers and nonsmokers, indicating that smokers focused more often on smoking-related cues than nonsmokers. Self-reports of craving are in agreement with these results and suggest a significant increase in craving after exposure to smoking cues. In sum, these data support the use of virtual environments for eliciting craving.

  5. Multiple Image Arrangement for Subjective Quality Assessment

    NASA Astrophysics Data System (ADS)

    Wang, Yan; Zhai, Guangtao

    2017-12-01

    Subjective quality assessment serves as the foundation for almost all visual quality related researches. Size of the image quality databases has expanded from dozens to thousands in the last decades. Since each subjective rating therein has to be averaged over quite a few participants, the ever-increasing overall size of those databases calls for an evolution of existing subjective test methods. Traditional single/double stimulus based approaches are being replaced by multiple image tests, where several distorted versions of the original one are displayed and rated at once. And this naturally brings upon the question of how to arrange those multiple images on screen during the test. In this paper, we answer this question by performing subjective viewing test with eye tracker for different types arrangements. Our research indicates that isometric arrangement imposes less duress on participants and has more uniform distribution of eye fixations and movements and therefore is expected to generate more reliable subjective ratings.

  6. Not all past events are equal: biased attention and emerging heuristics in children's past-to-future forecasting.

    PubMed

    Lagattuta, Kristin Hansen; Sayfan, Liat

    2013-01-01

    Four- to 10-year-olds and adults (N = 265) responded to eight scenarios presented on an eye tracker. Each trial involved a character who encounters a perpetrator who had previously enacted positive (P), negative (N), or both types of actions toward him or her in varying sequences (NN, PP, PN, and NP). Participants predicted the character's thoughts about the likelihood of future events, emotion type and intensity, and decision to approach or avoid. All ages made more positive forecasts for PP > NP > PN > NN trials, with differentiation by past experience widening with age. Age-related increases in weighting the most recent past event also appeared in eye gaze. Individual differences in biased visual attention correlated with verbal judgments. Findings contribute to research on risk assessment, person perception, and heuristics in judgment and decision making. © 2013 The Authors. Child Development © 2013 Society for Research in Child Development, Inc.

  7. Reading in Schizophrenic Subjects and Their Nonsymptomatic First-Degree Relatives

    PubMed Central

    Roberts, Eryl O.; Proudlock, Frank A.; Martin, Kate; Reveley, Michael A.; Al-Uzri, Mohammed; Gottlob, Irene

    2013-01-01

    Previous studies have demonstrated eye movement abnormalities during smooth pursuit and antisaccadic tasks in schizophrenia. However, eye movements have not been investigated during reading. The purpose of this study was to determine whether schizophrenic subjects and their nonsymptomatic first-degree relatives show eye movement abnormalities during reading. Reading rate, number of saccades per line, amplitudes of saccades, percentage regressions (reverse saccades), and fixation durations were measured using an eye tracker (EyeLink, SensoMotoric Instruments, Germany) in 38 schizophrenic volunteers, 14 nonaffected first-degree relatives, and 57 control volunteers matched for age and National Adult Reading Test scores. Parameters were examined when volunteers read full pages of text and text was limited to progressively smaller viewing areas around the point of fixation using a gaze-contingent window. Schizophrenic volunteers showed significantly slower reading rates (P = .004), increase in total number of saccades (P ≤ .001), and a decrease in saccadic amplitude (P = .025) while reading. Relatives showed a significant increase in total number of saccades (P = .013) and decrease in saccadic amplitude (P = .020). Limitation of parafoveal information by reducing the amount of visible characters did not change the reading rate of schizophrenics but controls showed a significant decrease in reading rate with reduced parafoveal information (P < .001). Eye movement abnormalities during reading of schizophrenic volunteers and their first-degree relatives suggest that visual integration of foveal and parafoveal information may be reduced in schizophrenia. Reading abnormalities in relatives suggest a genetic influence in reading ability in schizophrenia and rule out confounding effects of medication. PMID:22267532

  8. CIDER: Enabling Robustness-Power Tradeoffs on a Computational Eyeglass

    PubMed Central

    Mayberry, Addison; Tun, Yamin; Hu, Pan; Smith-Freedman, Duncan; Ganesan, Deepak; Marlin, Benjamin; Salthouse, Christopher

    2016-01-01

    The human eye offers a fascinating window into an individual’s health, cognitive attention, and decision making, but we lack the ability to continually measure these parameters in the natural environment. The challenges lie in: a) handling the complexity of continuous high-rate sensing from a camera and processing the image stream to estimate eye parameters, and b) dealing with the wide variability in illumination conditions in the natural environment. This paper explores the power–robustness tradeoffs inherent in the design of a wearable eye tracker, and proposes a novel staged architecture that enables graceful adaptation across the spectrum of real-world illumination. We propose CIDER, a system that operates in a highly optimized low-power mode under indoor settings by using a fast Search-Refine controller to track the eye, but detects when the environment switches to more challenging outdoor sunlight and switches models to operate robustly under this condition. Our design is holistic and tackles a) power consumption in digitizing pixels, estimating pupillary parameters, and illuminating the eye via near-infrared, b) error in estimating pupil center and pupil dilation, and c) model training procedures that involve zero effort from a user. We demonstrate that CIDER can estimate pupil center with error less than two pixels (0.6°), and pupil diameter with error of one pixel (0.22mm). Our end-to-end results show that we can operate at power levels of roughly 7mW at a 4Hz eye tracking rate, or roughly 32mW at rates upwards of 250Hz. PMID:27042165

  9. Dynamic torsional misalignment of eyes during laser in-situ keratomileusis.

    PubMed

    Shajari, Mehdi; Bühren, Jens; Kohnen, Thomas

    2016-05-01

    To determine the amount and characteristics of dynamic torsional misalignment of eyes during excimer ablation in laser in-situ keratomileusis (LASIK). Retrospective trial for evaluation of dynamic intraoperative torsional misalignment of 179 eyes that underwent LASIK for correction of myopia and/or astigmatism. Patients were treated with the Keracor 217z excimer laser implementing 25 Hz dynamic eye tracker ACE 100 (both Technolas Perfect Vision, Munich, Germany). From dynamic torsional misalignments, temporal power spectra were obtained by Fourier analysis up to a frequency of 12.5 Hz and an amplitude of ±15° from initial torsional status (limited by the tracking system). The f90, f95, and f99 criteria were defined as the frequency below which 90 %, 95 %, and 99 % of misalignments occur. A Wilcoxon rank sum test was performed to detect differences of f90, f95, and f99 in groups' gender, age, and eye (if both eyes underwent surgery at same day). Multiple regression analysis (MRA) was performed to evaluate possible preoperative predictors of f90, f95, and f99. Fourier analysis showed a dominance of high-frequency, low-power dynamic torsional misalignment. Mean f95 threshold of rotational movements was 4.89±2.12 Hz (median 4.54, ranging from 0.44 to 9.23 Hz). Wilcoxon rank sum test showed no differences in f90, f95, and f99 between groups' gender, age, and eye. MRA revealed age, gender, and optical zone as preoperative predictors on intraoperative f90, f95, and f99. Dynamic intraoperative torsional misalignments of eyes undergoing LASIK are dominated by low-frequency (slow), high-power (large) movements, with 95 % being slower than 4.89Hz regarding the spectrum analyzed (0-12.5Hz, ±15°). Movements can be predicted preoperatively by eye treated, patients' gender, and age in pre-LASIK diagnostics.

  10. Exploring eye movements in patients with glaucoma when viewing a driving scene.

    PubMed

    Crabb, David P; Smith, Nicholas D; Rauscher, Franziska G; Chisholm, Catharine M; Barbur, John L; Edgar, David F; Garway-Heath, David F

    2010-03-16

    Glaucoma is a progressive eye disease and a leading cause of visual disability. Automated assessment of the visual field determines the different stages in the disease process: it would be desirable to link these measurements taken in the clinic with patient's actual function, or establish if patients compensate for their restricted field of view when performing everyday tasks. Hence, this study investigated eye movements in glaucomatous patients when viewing driving scenes in a hazard perception test (HPT). The HPT is a component of the UK driving licence test consisting of a series of short film clips of various traffic scenes viewed from the driver's perspective each containing hazardous situations that require the camera car to change direction or slow down. Data from nine glaucomatous patients with binocular visual field defects and ten age-matched control subjects were considered (all experienced drivers). Each subject viewed 26 different films with eye movements simultaneously monitored by an eye tracker. Computer software was purpose written to pre-process the data, co-register it to the film clips and to quantify eye movements and point-of-regard (using a dynamic bivariate contour ellipse analysis). On average, and across all HPT films, patients exhibited different eye movement characteristics to controls making, for example, significantly more saccades (P<0.001; 95% confidence interval for mean increase: 9.2 to 22.4%). Whilst the average region of 'point-of-regard' of the patients did not differ significantly from the controls, there were revealing cases where patients failed to see a hazard in relation to their binocular visual field defect. Characteristics of eye movement patterns in patients with bilateral glaucoma can differ significantly from age-matched controls when viewing a traffic scene. Further studies of eye movements made by glaucomatous patients could provide useful information about the definition of the visual field component required for fitness to drive.

  11. Exploring Eye Movements in Patients with Glaucoma When Viewing a Driving Scene

    PubMed Central

    Crabb, David P.; Smith, Nicholas D.; Rauscher, Franziska G.; Chisholm, Catharine M.; Barbur, John L.; Edgar, David F.; Garway-Heath, David F.

    2010-01-01

    Background Glaucoma is a progressive eye disease and a leading cause of visual disability. Automated assessment of the visual field determines the different stages in the disease process: it would be desirable to link these measurements taken in the clinic with patient's actual function, or establish if patients compensate for their restricted field of view when performing everyday tasks. Hence, this study investigated eye movements in glaucomatous patients when viewing driving scenes in a hazard perception test (HPT). Methodology/Principal Findings The HPT is a component of the UK driving licence test consisting of a series of short film clips of various traffic scenes viewed from the driver's perspective each containing hazardous situations that require the camera car to change direction or slow down. Data from nine glaucomatous patients with binocular visual field defects and ten age-matched control subjects were considered (all experienced drivers). Each subject viewed 26 different films with eye movements simultaneously monitored by an eye tracker. Computer software was purpose written to pre-process the data, co-register it to the film clips and to quantify eye movements and point-of-regard (using a dynamic bivariate contour ellipse analysis). On average, and across all HPT films, patients exhibited different eye movement characteristics to controls making, for example, significantly more saccades (P<0.001; 95% confidence interval for mean increase: 9.2 to 22.4%). Whilst the average region of ‘point-of-regard’ of the patients did not differ significantly from the controls, there were revealing cases where patients failed to see a hazard in relation to their binocular visual field defect. Conclusions/Significance Characteristics of eye movement patterns in patients with bilateral glaucoma can differ significantly from age-matched controls when viewing a traffic scene. Further studies of eye movements made by glaucomatous patients could provide useful information about the definition of the visual field component required for fitness to drive. PMID:20300522

  12. Where Low and High Inference Data Converge: Validation of CLASS Assessment of Mathematics Instruction Using Mobile Eye Tracking with Expert and Novice Teachers

    ERIC Educational Resources Information Center

    Cortina, Kai S.; Miller, Kevin F.; McKenzie, Ryan; Epstein, Alanna

    2015-01-01

    Classroom observation research and research on teacher expertise are similar in their reliance on observational data with high-inference procedure to assess the quality of instruction. Expertise research usually uses low-inference measures like eye tracking to identify qualitative difference between expert and novice behaviors and cognition. In…

  13. NanoRacks Kestrel Eye (KE2M) Satellite Deployment

    NASA Image and Video Library

    2017-10-24

    iss053e130305 (Oct. 24, 2017) --- The Kestrel Eye IIM (KE2M) CubeSat is deployed from the tip of the Dextre attached to the Mobile Servicing System. The KE2M is carrying an optical imaging system payload that is being used to validate the concept of using microsatellites in low-Earth orbit to support critical operations.

  14. NanoRacks Kestrel Eye (KE2M) Satellite Deployment

    NASA Image and Video Library

    2017-10-24

    iss053e130267 (Oct. 24, 2017) --- The Kestrel Eye IIM (KE2M) CubeSat is deployed from the tip of the Dextre attached to the Mobile Servicing System. The KE2M is carrying an optical imaging system payload that is being used to validate the concept of using microsatellites in low-Earth orbit to support critical operations.

  15. Scattered radiation risk to the lens of the eyes for staff involved in using mobile C-arm fluoroscopy unit: Which position is riskiest?

    NASA Astrophysics Data System (ADS)

    Salleh, H.; Samat, S. B.; Matori, M. K.; Isa, M. J. M.

    2015-09-01

    Cataractogenesis is something to be concerned by radiologist and radiographer who work extensively in fluoroscopy. The increasing use of fluoroscopy or interventional fluoroscopy has to come with safety awareness on scattered radiation risk for staff performing the procedure. This study is looking into the radiation risk to the lens of the eyes for staff involved in fluoroscopy using the mobile C-arm fluoroscopy unit. The Toshiba SXT-1000A and Alderson Rando phantom were used in this study. Based on the results, it is found clearly that over couch (OC) procedure is riskier than under couch (UC) procedure. The cathode bound area is clearly riskier than anode bound area especially for UC procedure. More doses (at least +1,568 % of safest position) are received by the lens of the eyes for staff standing at the cathode bound area especially the position opposite to the x-ray tube.

  16. Scattered radiation risk to the lens of the eyes for staff involved in using mobile C-arm fluoroscopy unit: Which position is riskiest?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salleh, H.; Matori, M. K.; Isa, M. J. M.

    Cataractogenesis is something to be concerned by radiologist and radiographer who work extensively in fluoroscopy. The increasing use of fluoroscopy or interventional fluoroscopy has to come with safety awareness on scattered radiation risk for staff performing the procedure. This study is looking into the radiation risk to the lens of the eyes for staff involved in fluoroscopy using the mobile C-arm fluoroscopy unit. The Toshiba SXT-1000A and Alderson Rando phantom were used in this study. Based on the results, it is found clearly that over couch (OC) procedure is riskier than under couch (UC) procedure. The cathode bound area ismore » clearly riskier than anode bound area especially for UC procedure. More doses (at least +1,568 % of safest position) are received by the lens of the eyes for staff standing at the cathode bound area especially the position opposite to the x-ray tube.« less

  17. A method of reconstructing the spatial measurement network by mobile measurement transmitter for shipbuilding

    NASA Astrophysics Data System (ADS)

    Guo, Siyang; Lin, Jiarui; Yang, Linghui; Ren, Yongjie; Guo, Yin

    2017-07-01

    The workshop Measurement Position System (wMPS) is a distributed measurement system which is suitable for the large-scale metrology. However, there are some inevitable measurement problems in the shipbuilding industry, such as the restriction by obstacles and limited measurement range. To deal with these factors, this paper presents a method of reconstructing the spatial measurement network by mobile transmitter. A high-precision coordinate control network with more than six target points is established. The mobile measuring transmitter can be added into the measurement network using this coordinate control network with the spatial resection method. This method reconstructs the measurement network and broadens the measurement scope efficiently. To verify this method, two comparison experiments are designed with the laser tracker as the reference. The results demonstrate that the accuracy of point-to-point length is better than 0.4mm and the accuracy of coordinate measurement is better than 0.6mm.

  18. Integration of Mobile Health Technology in the Treatment of Chronic Pain: A Critical Review.

    PubMed

    Sundararaman, Lalitha V; Edwards, Robert R; Ross, Edgar L; Jamison, Robert N

    This article provides a critical overview and best-evidence synthesis of the use of mobile health (mHealth) technology among persons with chronic pain and their health care providers and examines the future benefits and barriers of implementing mHealth technology in clinical care. We critically review articles about electronic pain diaries, pain assessment programs, text messaging, and smartphone pain apps for management of persons with pain. Also presented are findings on the utility of activity trackers and use of telehealth to deliver cognitive behavioral therapy. Finally, barriers, study gaps, and future challenges of incorporating mobile technology for chronic pain are discussed. Although the future of mHealth technology and telemedicine in clinical practice is promising, this critical review highlights the need for rigorous studies to establish an association of the use of mHealth technology with improved quality of life, functional autonomy, and decreased hospital use.

  19. Does Visual Impairment Affect Mobility Over Time? The Salisbury Eye Evaluation Study

    PubMed Central

    Swenor, Bonnielin K.; Muñoz, Beatriz; West, Sheila K.

    2013-01-01

    Purpose. To determine if the odds of mobility disability increases at a different rate among visually impaired (VI) as compared with nonvisually impaired (NVI) over an 8-year period. Methods. A total of 2520 Salisbury Eye Evaluation Study participants were followed 2, 6, and 8 years after baseline. VI was defined as best-corrected visual acuity worse than 20/40, or visual field of approximately less than 20°. Self-reported difficulty with three tasks was assessed at each visit: walking up 10 steps, walking down 10 steps, and walking 150 feet. Generalized estimating equation models included a 6-year spline, and explored differences in mobility difficulty trajectories by including an interaction between VI status and the spline terms. Odds ratios (OR) and 95% confidence intervals (CI) compared mobility difficulty for each task by VI status. Results. At baseline, the VI were significantly more likely to report difficulty mobility tasks than the NVI (ORdifficultywalkingup10steps = 1.37, CI: 1.02–1.80; ORdifficultywalkingdown10steps = 1.55, CI: 1.16–2.08; ORdifficultywalking150feet = 1.50, CI: 1.10–2.04). The trajectory of mobility disability did not differ by VI status from baseline to the 6-year visit. However, the difference between the VI and NVI declined at the 8-year visit, which may be due to loss of VI participants at risk of developing mobility difficulty. Conclusions. The VI were more likely to report mobility disability than the NVI, but the trajectory of mobility disability was not steeper among the VI as compared to the NVI over the study period. PMID:24176902

  20. Sensorimotor integration of vision and proprioception for obstacle crossing in ambulatory individuals with spinal cord injury.

    PubMed

    Malik, Raza Naseem; Cote, Rachel; Lam, Tania

    2017-01-01

    Skilled walking, such as obstacle crossing, is an essential component of functional mobility. Sensorimotor integration of visual and proprioceptive inputs is important for successful obstacle crossing. The objective of this study was to understand how proprioceptive deficits affect obstacle-crossing strategies when controlling for variations in motor deficits in ambulatory individuals with spinal cord injury (SCI). Fifteen ambulatory individuals with SCI and 15 able-bodied controls were asked to step over an obstacle scaled to their motor abilities under full and obstructed vision conditions. An eye tracker was used to determine gaze behaviour and motion capture analysis was used to determine toe kinematics relative to the obstacle. Combined, bilateral hip and knee proprioceptive sense (joint position sense and movement detection sense) was assessed using the Lokomat and customized software controls. Combined, bilateral hip and knee proprioceptive sense in subjects with SCI varied and was significantly different from able-bodied subjects. Subjects with greater proprioceptive deficits stepped higher over the obstacle with their lead and trail limbs in the obstructed vision condition compared with full vision. Subjects with SCI also glanced at the obstacle more frequently and with longer fixation times compared with controls, but this was not related to proprioceptive sense. This study indicates that ambulatory individuals with SCI rely more heavily on vision to cross obstacles and show impairments in key gait parameters required for successful obstacle crossing. Our data suggest that proprioceptive deficits need to be considered in rehabilitation programs aimed at improving functional mobility in ambulatory individuals with SCI. This work is unique since it examines the contribution of combined, bilateral hip and knee proprioceptive sense on the recovery of skilled walking function, in addition to characterizing gaze behavior during a skilled walking task in people with motor-incomplete spinal cord injury. Copyright © 2017 the American Physiological Society.

  1. Osteo-odonto-keratoprosthesis for end-stage cornea blindness.

    PubMed

    Wong, H S; Then, K Y; Ramli, R

    2011-10-01

    We report the first case of Osteo-odonto-keratoprosthesis (OOKP) who successfully underwent surgery in Malaysia following a grade 4 (severe) chemical injury in both eyes in 2006. The patient's left eye was eviscerated and his right eye underwent penetrating keratoplasty. However, the corneal graft failed and became opaque. His right eye could only perceive light. The OOKP was offered to him hoping to recover some functional vision. He underwent a 2-stage surgery to implant the OOKP into his right eye. However, 2 months post-operation, he developed vitreous haemorrhage. A successful pars plana vitrectomy (PPV) was performed via the limited view through the lens. He attained a final visual acuity of 6/60 (N36). He was able to mobilize more independently, feed, dress himself and read large print.

  2. Engagement Strategies for Self-Monitoring Symptoms of Bipolar Disorder With Mobile and Wearable Technology: Protocol for a Randomized Controlled Trial.

    PubMed

    Cochran, Amy; Belman-Wells, Livia; McInnis, Melvin

    2018-05-10

    Monitoring signs and symptoms in bipolar disorder (BP) is typically based on regular assessments from patient-clinician interactions. Mobile and wearable technology promises to make monitoring symptoms in BP easier, but little is known about how best to engage individuals with BP in monitoring symptoms. The objective of this study was to provide the rationale and protocol for a randomized controlled trial that investigates engagement strategies for monitoring symptoms of BP, including the strategies of using activity trackers compared with self-reports and reviewing recorded symptoms weekly with an interviewer. A total of 50 individuals with BP will be recruited from the Prechter Longitudinal Study of Bipolar Disorder at the University of Michigan to participate in a 6-week study. Participants will monitor their symptoms through an activity tracker (Fitbit Alta HR) and a mobile phone app designed for this study. In addition to monitoring symptoms, participants have a 50-50 chance of being assigned to an arm that reviews self-reports and activity information weekly. Statistical tests will be performed to test hypotheses that participants adhere to activity tracking significantly more than self-reporting, prefer activity tracking significantly more than self-reporting, and better adhere to both activity tracking and self-reporting when reviewing collected information weekly. Recruitment commenced in November 2017. The first group of participants began the study in January 2018. This study aims to establish strategies to engage individuals with BP in monitoring their symptoms with mobile and wearable technology. Better engagement strategies are expected to aid current efforts in bipolar research and clinical care, from the development of new mobile phone apps to providing the right intervention to the right individual at the right moment. ClinicalTrials.gov NCT03358238; https://clinicaltrials.gov/ct2/show/NCT03358238 (Archived by WebCite at http://www.webcitation.org/6yebuNfz5). RR1-10.2196/9899. ©Amy Cochran, Livia Belman-Wells, Melvin McInnis. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 10.05.2018.

  3. Person detection, tracking and following using stereo camera

    NASA Astrophysics Data System (ADS)

    Wang, Xiaofeng; Zhang, Lilian; Wang, Duo; Hu, Xiaoping

    2018-04-01

    Person detection, tracking and following is a key enabling technology for mobile robots in many human-robot interaction applications. In this article, we present a system which is composed of visual human detection, video tracking and following. The detection is based on YOLO(You only look once), which applies a single convolution neural network(CNN) to the full image, thus can predict bounding boxes and class probabilities directly in one evaluation. Then the bounding box provides initial person position in image to initialize and train the KCF(Kernelized Correlation Filter), which is a video tracker based on discriminative classifier. At last, by using a stereo 3D sparse reconstruction algorithm, not only the position of the person in the scene is determined, but also it can elegantly solve the problem of scale ambiguity in the video tracker. Extensive experiments are conducted to demonstrate the effectiveness and robustness of our human detection and tracking system.

  4. Reactive and anticipatory looking in 6-month-old infants during a visual expectation paradigm.

    PubMed

    Quan, Jeffry; Bureau, Jean-François; Abdul Malik, Adam B; Wong, Johnny; Rifkin-Graboi, Anne

    2017-10-01

    This article presents data from 278 six-month-old infants who completed a visual expectation paradigm in which audiovisual stimuli were first presented randomly (random phase), and then in a spatial pattern (pattern phase). Infants' eye gaze behaviour was tracked with a 60 Hz Tobii eye-tracker in order to measure two types of looking behaviour: reactive looking (i.e., latency to shift eye gaze in reaction to the appearance of stimuli) and anticipatory looking (i.e., percentage of time spent looking at the location where the next stimulus is about to appear during the inter-stimulus interval). Data pertaining to missing data and task order effects are presented. Further analyses show that infants' reactive looking was faster in the pattern phase, compared to the random phase, and their anticipatory looking increased from random to pattern phases. Within the pattern phase, infants' reactive looking showed a quadratic trend, with reactive looking time latencies peaking in the middle portion of the phase. Similarly, within the pattern phase, infants' anticipatory looking also showed a quadratic trend, with anticipatory looking peaking during the middle portion of the phase.

  5. Consequences of cognitive impairments following traumatic brain injury: Pilot study on visual exploration while driving.

    PubMed

    Milleville-Pennel, Isabelle; Pothier, Johanna; Hoc, Jean-Michel; Mathé, Jean-François

    2010-01-01

    The aim was to assess the visual exploration of a person suffering from traumatic brain injury (TBI). It was hypothesized that visual exploration could be modified as a result of attentional or executive function deficits that are often observed following brain injury. This study compared an analysis of eyes movements while driving with data from neuropsychological tests. Five participants suffering from TBI and six control participants took part in this study. All had good driving experience. They were invited to drive on a fixed-base driving simulator. Eye fixations were recorded using an eye tracker. Neuropsychological tests were used to assess attention, working memory, rapidity of information processing and executive functions. Participants with TBI showed a reduction in the variety of the visual zones explored and a reduction of the distance of exploration. Moreover, neuropsychological evaluation indicates that there were difficulties in terms of divided attention, anticipation and planning. There is a complementarity of the information obtained. Tests give information about cognitive deficiencies but not about their translation into a dynamic situation. Conversely, visual exploration provides information about the dynamic with which information is picked up in the environment but not about the cognitive processes involved.

  6. Effects of monetary reward and punishment on information checking behaviour: An eye-tracking study.

    PubMed

    Li, Simon Y W; Cox, Anna L; Or, Calvin; Blandford, Ann

    2018-07-01

    The aim of the present study was to investigate the effect of error consequence, as reward or punishment, on individuals' checking behaviour following data entry. This study comprised two eye-tracking experiments that replicate and extend the investigation of Li et al. (2016) into the effect of monetary reward and punishment on data-entry performance. The first experiment adopted the same experimental setup as Li et al. (2016) but additionally used an eye tracker. The experiment validated Li et al. (2016) finding that, when compared to no error consequence, both reward and punishment led to improved data-entry performance in terms of reducing errors, and that no performance difference was found between reward and punishment. The second experiment extended the earlier study by associating error consequence to each individual trial by providing immediate performance feedback to participants. It was found that gradual increment (i.e. reward feedback) also led to significantly more accurate performance than no error consequence. It is unclear whether gradual increment is more effective than gradual decrement because of the small sample size tested. However, this study reasserts the effectiveness of reward on data-entry performance. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. An Active Vision Approach to Understanding and Improving Visual Training in the Geosciences

    NASA Astrophysics Data System (ADS)

    Voronov, J.; Tarduno, J. A.; Jacobs, R. A.; Pelz, J. B.; Rosen, M. R.

    2009-12-01

    Experience in the field is a fundamental aspect of geologic training, and its effectiveness is largely unchallenged because of anecdotal evidence of its success among expert geologists. However, there have been only a few quantitative studies based on large data collection efforts to investigate how Earth Scientists learn in the field. In a recent collaboration between Earth scientists, Cognitive scientists and experts in Imaging science at the University of Rochester and Rochester Institute of Technology, we are investigating such a study. Within Cognitive Science, one school of thought, referred to as the Active Vision approach, emphasizes that visual perception is an active process requiring us to move our eyes to acquire new information about our environment. The Active Vision approach indicates the perceptual skills which experts possess and which novices will need to acquire to achieve expert performance. We describe data collection efforts using portable eye-trackers to assess how novice and expert geologists acquire visual knowledge in the field. We also discuss our efforts to collect images for use in a semi-immersive classroom environment, useful for further testing of novices and experts using eye-tracking technologies.

  8. A Data Model and Task Space for Data of Interest (DOI) Eye-Tracking Analyses.

    PubMed

    Jianu, Radu; Alam, Sayeed Safayet

    2018-03-01

    Eye-tracking data is traditionally analyzed by looking at where on a visual stimulus subjects fixate, or, to facilitate more advanced analyses, by using area-of-interests (AOI) defined onto visual stimuli. Recently, there is increasing interest in methods that capture what users are looking at rather than where they are looking. By instrumenting visualization code that transforms a data model into visual content, gaze coordinates reported by an eye-tracker can be mapped directly to granular data shown on the screen, producing temporal sequences of data objects that subjects viewed in an experiment. Such data collection, which is called gaze to object mapping (GTOM) or data-of-interest analysis (DOI), can be done reliably with limited overhead and can facilitate research workflows not previously possible. Our paper contributes to establishing a foundation of DOI analyses by defining a DOI data model and highlighting its differences to AOI data in structure and scale; by defining and exemplifying a space of DOI enabled tasks; by describing three concrete examples of DOI experimentation in three different domains; and by discussing immediate research challenges in creating a framework of visual support for DOI experimentation and analysis.

  9. Individual predictions of eye-movements with dynamic scenes

    NASA Astrophysics Data System (ADS)

    Barth, Erhardt; Drewes, Jan; Martinetz, Thomas

    2003-06-01

    We present a model that predicts saccadic eye-movements and can be tuned to a particular human observer who is viewing a dynamic sequence of images. Our work is motivated by applications that involve gaze-contingent interactive displays on which information is displayed as a function of gaze direction. The approach therefore differs from standard approaches in two ways: (1) we deal with dynamic scenes, and (2) we provide means of adapting the model to a particular observer. As an indicator for the degree of saliency we evaluate the intrinsic dimension of the image sequence within a geometric approach implemented by using the structure tensor. Out of these candidate saliency-based locations, the currently attended location is selected according to a strategy found by supervised learning. The data are obtained with an eye-tracker and subjects who view video sequences. The selection algorithm receives candidate locations of current and past frames and a limited history of locations attended in the past. We use a linear mapping that is obtained by minimizing the quadratic difference between the predicted and the actually attended location by gradient descent. Being linear, the learned mapping can be quickly adapted to the individual observer.

  10. Are 6-month-old human infants able to transfer emotional information (happy or angry) from voices to faces? An eye-tracking study.

    PubMed

    Palama, Amaya; Malsert, Jennifer; Gentaz, Edouard

    2018-01-01

    The present study examined whether 6-month-old infants could transfer amodal information (i.e. independently of sensory modalities) from emotional voices to emotional faces. Thus, sequences of successive emotional stimuli (voice or face from one sensory modality -auditory- to another sensory modality -visual-), corresponding to a cross-modal transfer, were displayed to 24 infants. Each sequence presented an emotional (angry or happy) or neutral voice, uniquely, followed by the simultaneous presentation of two static emotional faces (angry or happy, congruous or incongruous with the emotional voice). Eye movements in response to the visual stimuli were recorded with an eye-tracker. First, results suggested no difference in infants' looking time to happy or angry face after listening to the neutral voice or the angry voice. Nevertheless, after listening to the happy voice, infants looked longer at the incongruent angry face (the mouth area in particular) than the congruent happy face. These results revealed that a cross-modal transfer (from auditory to visual modalities) is possible for 6-month-old infants only after the presentation of a happy voice, suggesting that they recognize this emotion amodally.

  11. Learning-based saliency model with depth information.

    PubMed

    Ma, Chih-Yao; Hang, Hsueh-Ming

    2015-01-01

    Most previous studies on visual saliency focused on two-dimensional (2D) scenes. Due to the rapidly growing three-dimensional (3D) video applications, it is very desirable to know how depth information affects human visual attention. In this study, we first conducted eye-fixation experiments on 3D images. Our fixation data set comprises 475 3D images and 16 subjects. We used a Tobii TX300 eye tracker (Tobii, Stockholm, Sweden) to track the eye movement of each subject. In addition, this database contains 475 computed depth maps. Due to the scarcity of public-domain 3D fixation data, this data set should be useful to the 3D visual attention research community. Then, a learning-based visual attention model was designed to predict human attention. In addition to the popular 2D features, we included the depth map and its derived features. The results indicate that the extra depth information can enhance the saliency estimation accuracy specifically for close-up objects hidden in a complex-texture background. In addition, we examined the effectiveness of various low-, mid-, and high-level features on saliency prediction. Compared with both 2D and 3D state-of-the-art saliency estimation models, our methods show better performance on the 3D test images. The eye-tracking database and the MATLAB source codes for the proposed saliency model and evaluation methods are available on our website.

  12. Unification of automatic target tracking and automatic target recognition

    NASA Astrophysics Data System (ADS)

    Schachter, Bruce J.

    2014-06-01

    The subject being addressed is how an automatic target tracker (ATT) and an automatic target recognizer (ATR) can be fused together so tightly and so well that their distinctiveness becomes lost in the merger. This has historically not been the case outside of biology and a few academic papers. The biological model of ATT∪ATR arises from dynamic patterns of activity distributed across many neural circuits and structures (including retina). The information that the brain receives from the eyes is "old news" at the time that it receives it. The eyes and brain forecast a tracked object's future position, rather than relying on received retinal position. Anticipation of the next moment - building up a consistent perception - is accomplished under difficult conditions: motion (eyes, head, body, scene background, target) and processing limitations (neural noise, delays, eye jitter, distractions). Not only does the human vision system surmount these problems, but it has innate mechanisms to exploit motion in support of target detection and classification. Biological vision doesn't normally operate on snapshots. Feature extraction, detection and recognition are spatiotemporal. When vision is viewed as a spatiotemporal process, target detection, recognition, tracking, event detection and activity recognition, do not seem as distinct as they are in current ATT and ATR designs. They appear as similar mechanism taking place at varying time scales. A framework is provided for unifying ATT and ATR.

  13. The Development of Expertise in Radiology: In Chest Radiograph Interpretation, "Expert" Search Pattern May Predate "Expert" Levels of Diagnostic Accuracy for Pneumothorax Identification.

    PubMed

    Kelly, Brendan S; Rainford, Louise A; Darcy, Sarah P; Kavanagh, Eoin C; Toomey, Rachel J

    2016-07-01

    Purpose To investigate the development of chest radiograph interpretation skill through medical training by measuring both diagnostic accuracy and eye movements during visual search. Materials and Methods An institutional exemption from full ethical review was granted for the study. Five consultant radiologists were deemed the reference expert group, and four radiology registrars, five senior house officers (SHOs), and six interns formed four clinician groups. Participants were shown 30 chest radiographs, 14 of which had a pneumothorax, and were asked to give their level of confidence as to whether a pneumothorax was present. Receiver operating characteristic (ROC) curve analysis was carried out on diagnostic decisions. Eye movements were recorded with a Tobii TX300 (Tobii Technology, Stockholm, Sweden) eye tracker. Four eye-tracking metrics were analyzed. Variables were compared to identify any differences between groups. All data were compared by using the Friedman nonparametric method. Results The average area under the ROC curve for the groups increased with experience (0.947 for consultants, 0.792 for registrars, 0.693 for SHOs, and 0.659 for interns; P = .009). A significant difference in diagnostic accuracy was found between consultants and registrars (P = .046). All four eye-tracking metrics decreased with experience, and there were significant differences between registrars and SHOs. Total reading time decreased with experience; it was significantly lower for registrars compared with SHOs (P = .046) and for SHOs compared with interns (P = .025). Conclusion Chest radiograph interpretation skill increased with experience, both in terms of diagnostic accuracy and visual search. The observed level of experience at which there was a significant difference was higher for diagnostic accuracy than for eye-tracking metrics. (©) RSNA, 2016 Online supplemental material is available for this article.

  14. The effect of search condition and advertising type on visual attention to Internet advertising.

    PubMed

    Kim, Gho; Lee, Jang-Han

    2011-05-01

    This research was conducted to examine the level of consumers' visual attention to Internet advertising. It was predicted that consumers' search type would influence visual attention to advertising. Specifically, it was predicted that more attention to advertising would be attracted in the exploratory search condition than in the goal-directed search condition. It was also predicted that there would be a difference in visual attention depending on the advertisement type (advertising type: text vs. pictorial advertising). An eye tracker was used for measurement. Results revealed that search condition and advertising type influenced advertising effectiveness.

  15. An overview of human genetic privacy

    PubMed Central

    Shi, Xinghua; Wu, Xintao

    2016-01-01

    The study of human genomics is becoming a Big Data science, owing to recent biotechnological advances leading to availability of millions of personal genome sequences, which can be combined with biometric measurements from mobile apps and fitness trackers, and of human behavior data monitored from mobile devices and social media. With increasing research opportunities for integrative genomic studies through data sharing, genetic privacy emerges as a legitimate yet challenging concern that needs to be carefully addressed, not only for individuals but also for their families. In this paper, we present potential genetic privacy risks and relevant ethics and regulations for sharing and protecting human genomics data. We also describe the techniques for protecting human genetic privacy from three broad perspectives: controlled access, differential privacy, and cryptographic solutions. PMID:27626905

  16. Optimizing virtual reality for all users through gaze-contingent and adaptive focus displays.

    PubMed

    Padmanaban, Nitish; Konrad, Robert; Stramer, Tal; Cooper, Emily A; Wetzstein, Gordon

    2017-02-28

    From the desktop to the laptop to the mobile device, personal computing platforms evolve over time. Moving forward, wearable computing is widely expected to be integral to consumer electronics and beyond. The primary interface between a wearable computer and a user is often a near-eye display. However, current generation near-eye displays suffer from multiple limitations: they are unable to provide fully natural visual cues and comfortable viewing experiences for all users. At their core, many of the issues with near-eye displays are caused by limitations in conventional optics. Current displays cannot reproduce the changes in focus that accompany natural vision, and they cannot support users with uncorrected refractive errors. With two prototype near-eye displays, we show how these issues can be overcome using display modes that adapt to the user via computational optics. By using focus-tunable lenses, mechanically actuated displays, and mobile gaze-tracking technology, these displays can be tailored to correct common refractive errors and provide natural focus cues by dynamically updating the system based on where a user looks in a virtual scene. Indeed, the opportunities afforded by recent advances in computational optics open up the possibility of creating a computing platform in which some users may experience better quality vision in the virtual world than in the real one.

  17. Optimizing virtual reality for all users through gaze-contingent and adaptive focus displays

    NASA Astrophysics Data System (ADS)

    Padmanaban, Nitish; Konrad, Robert; Stramer, Tal; Cooper, Emily A.; Wetzstein, Gordon

    2017-02-01

    From the desktop to the laptop to the mobile device, personal computing platforms evolve over time. Moving forward, wearable computing is widely expected to be integral to consumer electronics and beyond. The primary interface between a wearable computer and a user is often a near-eye display. However, current generation near-eye displays suffer from multiple limitations: they are unable to provide fully natural visual cues and comfortable viewing experiences for all users. At their core, many of the issues with near-eye displays are caused by limitations in conventional optics. Current displays cannot reproduce the changes in focus that accompany natural vision, and they cannot support users with uncorrected refractive errors. With two prototype near-eye displays, we show how these issues can be overcome using display modes that adapt to the user via computational optics. By using focus-tunable lenses, mechanically actuated displays, and mobile gaze-tracking technology, these displays can be tailored to correct common refractive errors and provide natural focus cues by dynamically updating the system based on where a user looks in a virtual scene. Indeed, the opportunities afforded by recent advances in computational optics open up the possibility of creating a computing platform in which some users may experience better quality vision in the virtual world than in the real one.

  18. Long-range active retroreflector to measure the rotational orientation in conjunction with a laser tracker

    NASA Astrophysics Data System (ADS)

    Hofherr, O.; Wachten, Christian; Müller, C.; Reinecke, H.

    2014-11-01

    High precision optical non-contact position measurement is a key technology in modern engineering. Laser trackers (LT) accurately determine x-y-z coordinates of passive retroreflectors. Next-generation systems answer the need to measure an object`s rotational orientation (pitch, yaw, roll). So far, these devices are based either on photogrammetry or on enhanced retroreflectors. Here we present a new method to measure all six degrees of freedom in conjunction with a LT. The basic principle is to analyze the orientation to the LT's beam path by coupling-out laser radiation. The optical design is inspired by a cat's eye retroreflector equipped with an integrated beam splitter layer. The optical spherical aberration is compensated, which reduces the divergence angle for the reflected beam by one order of magnitude compared to an uncompensated standard system of the same size. The wave front distortion is reduced to less than 0.1 λ @ 633 nm for beam diameters up to 8 mm. Our active retroreflector is suitable for long-range measurements for a distance > 10 m.

  19. Mobile Information Collection Application: Water Equipment Tracker (MICA:WET) Tool

    DTIC Science & Technology

    2013-10-01

    position unless so designated by other authorized documents. DESTROY THIS REPORT WHEN NO LONGER NEEDED. DO NOT RETURN IT TO THE ORIGINATOR. ERDC TR...for the report. Despite this utility, an ongoing programming “ bug ” causes photos to be- come associated with the wrong building, floor, and room after...other sleeping quarters, number of beds , demographic percentages. Some fields require the user to enter the data manually or to select from a menu

  20. Technology-Assisted Behavioral Intervention to Extend Sleep Duration: Development and Design of the Sleep Bunny Mobile App.

    PubMed

    Baron, Kelly Glazer; Duffecy, Jennifer; Reid, Kathryn; Begale, Mark; Caccamo, Lauren

    2018-01-10

    Despite the high prevalence of short sleep duration (29.2% of adults sleep <6 hours on weekdays), there are no existing theory-based behavioral interventions to extend sleep duration. The popularity of wearable sleep trackers provides an opportunity to engage users in interventions. The objective of this study was to outline the theoretical foundation and iterative process of designing the "Sleep Bunny," a technology-assisted sleep extension intervention including a mobile phone app, wearable sleep tracker, and brief telephone coaching. We conducted a two-step process in the development of this intervention, which was as follows: (1) user testing of the app and (2) a field trial that was completed by 2 participants with short sleep duration and a cardiovascular disease risk factor linked to short sleep duration (body mass index [BMI] >25). All participants had habitual sleep duration <6.5 hours verified by 7 days of actigraphy. A total of 6 individuals completed initial user testing in the development phase, and 2 participants completed field testing. Participants in the user testing and field testing responded to open-ended surveys about the design and utility of the app. Participants in the field testing completed the Epworth Sleepiness Scale and also wore an actigraph for a 1-week baseline period and during the 4-week intervention period. The feedback suggests that users enjoyed the wearable sleep tracker and found the app visually pleasing, but they suggested improvements to the notification and reminder features of the app. The 2 participants who completed the field test demonstrated significant improvements in sleep duration and daytime sleepiness. Further testing is needed to determine effects of this intervention in populations at risk for the mental and physical consequences of sleep loss. ©Kelly Glazer Baron, Jennifer Duffecy, Kathryn Reid, Mark Begale, Lauren Caccamo. Originally published in JMIR Mental Health (http://mental.jmir.org), 10.01.2018.

  1. Development of a low cost pupillometer-eyetracker and applications

    NASA Astrophysics Data System (ADS)

    Bianchetti, Arturo; Perez, Liliana I.; Comastri, Silvia A.

    2013-11-01

    The determination of ocular pupil diameter and gaze direction is important in various psychophysical and cognitive tests and can be accomplished using commercial, academic or open-source devices. In this work we develop a table-top pupillometer eyetracker termed Blick, the hardware costs 50 dollars and the software is open source (https://github.com/abianchetti/blick). The hardware is mounted in a portable holder and comprises an illumination system (two infrared LEDs generating 0.13 W/m2 at 22 cm) and a detection system (containing an USB camera, an infrared filter and a 16mm lens system) The software, programmed in C++ using OpenCV and cvblob libraries, processes eye images in real time and supplies plots and tables of pupil diameter and gaze direction and a video of the eye. As applications, capturing the right eye of six young emmetropes and after performing the pixel-mm and homographic calibrations (required to determine diameter in mm and gaze direction), we conduct three tests. The corresponding tasks are to detect mistakes in three series of four poker cards, to recognize letters F between distractors and to write a sentence via eye movements using Blick as eye tracker and the tool Dasher (MacKayśs Cambridge Group). We obtain that Blicḱs performance is satisfactory (errors being 0.05 mm in pupil diameter and 1 degree in gaze direction); that there are slight pupil dilations when subjects used to playing cards find mistakes and when some subjects find targets and, finally, that Blick can be employed as eyetracker to allow communication of disabled persons.

  2. Mixed pro and antisaccade performance in children and adults.

    PubMed

    Irving, Elizabeth L; Tajik-Parvinchi, Diana J; Lillakas, Linda; González, Esther G; Steinbach, Martin J

    2009-02-19

    Pro and antisaccades are usually presented in blocks of similar type but they can also be presented such that prosaccade and antisaccade eye movements are mixed and a cue, usually the shape/colour of the fixation target or the peripheral target, determines which type of eye movement is required in a particular trial. A mixed-saccade task theoretically equalizes the inhibitory requirements for pro and antisaccades. Using a mixed-saccade task paradigm the aims of the study were to: 1) compare pro and antisaccades of children, 2) compare performance of children and adults and 3) explore the effect of increased working memory load in adults. The eye movements of 22 children (5-12 years) and 22 adults (20-51 years) were examined using a video-based eye tracking system (El-Mar Series 2020 Eye Tracker, Toronto, Canada). The task was a mixed-saccade task of pro and antisaccades and the colour of the peripheral target was the cue for whether the required saccade was to be a pro or an antisaccade. The children performed the mixed-saccade task and 11 adults performed the same mixed-saccade task alone and in a dual-task paradigm (together with mental subtraction or number repetition). A second group of 11 adults performed the mixed-saccade task alone. Children made mainly antisaccade errors. The adults' error rates increased in the mental subtraction dual-task condition but both antisaccade and prosaccade errors were made. It was concluded that the increased error rates of these two groups are reflective of different processing dynamics.

  3. Controlling Posture and Vergence Eye Movements in Quiet Stance: Effects of Thin Plantar Inserts

    PubMed Central

    Foisy, A.; Gaertner, C.; Matheron, E.; Kapoula, Z.

    2015-01-01

    The purpose of this study was to assess properties of vergence and saccade eye movements as well as posture in quiet stance, and the effects of thin plantar inserts upon postural and oculomotor control. The performances of 36 young healthy subjects were recorded by a force platform and an eye tracker in three testing conditions: without plantar stimulation, with a 3 millimetre-thick plantar insert, either a Medial or a Lateral Arch Support (MAS / LAS). The results showed a decrease of the Surface and Variance of Speed and a more posterior position of the CoP with either stimulation compared with the control condition. The fractal analysis showed a decrease with MAS. Wavelet analysis in the time-frequency domain revealed an increase in the Cancelling Time of the low frequency band with MAS. These results suggest a better stability for a lower energy cost. Concerning eye movements, the inserts influenced only vergence (not saccades): MAS caused an increase of the phasic amplitude of divergence, and conversely a decrease of the tonic amplitude. In contrast, LAS caused an increase of the tonic amplitude of convergence. Thus, MAS renders divergence less visually driven, while LAS renders convergence more visually driven. We conclude that the CNS uses the podal signal for both postural and vergence control via specific mechanisms. Plantar inserts have an influence upon posture and vergence movements in a different way according to the part of the foot sole being stimulated. These results can be useful to clinicians interested in foot or eye. PMID:26637132

  4. Effects of Direct Systematic Instruction on Google Glass Orientation with Individuals with Intellectual Disability

    ERIC Educational Resources Information Center

    Kelley, Kelly R.; Rivera, Christopher J.; Kellems, Ryan O.

    2016-01-01

    Glass, designed by Google, is a fairly new wearable and mobile technology that projects an image into a glass prism above the eye and is currently in beta testing. A touch pad on the side of Glass allows users to engage with the device through swiping gestures and voice control to perform several functions similar to mobile devices. This initial…

  5. Using parallel evolutionary development for a biologically-inspired computer vision system for mobile robots.

    PubMed

    Wright, Cameron H G; Barrett, Steven F; Pack, Daniel J

    2005-01-01

    We describe a new approach to attacking the problem of robust computer vision for mobile robots. The overall strategy is to mimic the biological evolution of animal vision systems. Our basic imaging sensor is based upon the eye of the common house fly, Musca domestica. The computational algorithms are a mix of traditional image processing, subspace techniques, and multilayer neural networks.

  6. Distribution of light in the human retina under natural viewing conditions

    NASA Astrophysics Data System (ADS)

    Gibert, Jorge C.

    Age-related macular degeneration (AMD) is the leading cause of blindness inAmerica. The fact that AMD wreaks most of the damage in the center of the retina raises the question of whether light, integrated over long periods, is more concentrated in the macula. A method, based on eye-tracking, was developed to measure the distribution of light in the retina under natural viewing conditions. The hypothesis was that integrated over time, retinal illumination peaked in the macula. Additionally a possible relationship between age and retinal illumination was investigated. The eye tracker superimposed the subject's gaze position on a video recorded by a scene camera. Five informed subjects were employed in feasibility tests, and 58 naive subjects participated in 5 phases. In phase 1 the subjects viewed a gray-scale image. In phase 2, they observed a sequence of photographic images. In phase 3 they viewed a video. In phase 4, they worked on a computer; in phase 5, the subjects walked around freely. The informed subjects were instructed to gaze at bright objects in the field of view and then at dark objects. Naive subjects were allowed to gaze freely for all phases. Using the subject's gaze coordinates, and the video provided by the scene camera, the cumulative light distribution on the retina was calculated for ˜15° around the fovea. As expected for control subjects, cumulative retinal light distributions peaked and dipped in the fovea when they gazed at bright or dark objects respectively. The light distribution maps obtained from the naive subjects presented a tendency to peak in the macula for phases 1, 2, and 3, a consistent tendency in phase 4 and a variable tendency in phase 5. The feasibility of using an eye-tracker system to measure the distribution of light in the retina was demonstrated, thus helping to understand the role played by light exposure in the etiology of AMD. Results showed that a tendency for light to peak in the macula is a characteristic of some individuals and of certain tasks. In these situations, risk of AMD could be increased. No significant difference was observed based on age.

  7. Using a familiar risk comparison within a risk ladder to improve risk understanding by low numerates: a study of visual attention.

    PubMed

    Keller, Carmen

    2011-07-01

    Previous experimental research provides evidence that a familiar risk comparison within a risk ladder is understood by low- and high-numerate individuals. It especially helps low numerates to better evaluate risk. In the present study, an eye tracker was used to capture individuals' visual attention to a familiar risk comparison, such as the risk associated with smoking. Two parameters of information processing-efficiency and level-were derived from visual attention. A random sample of participants from the general population (N= 68) interpreted a given risk level with the help of the risk ladder. Numeracy was negatively correlated with overall visual attention on the risk ladder (r(s) =-0.28, p= 0.01), indicating that the lower the numeracy, the more the time spent looking at the whole risk ladder. Numeracy was positively correlated with the efficiency of processing relevant frequency (r(s) = 0.34, p < 0.001) and relevant textual information (r(s) = 0.34, p < 0.001), but not with the efficiency of processing relevant comparative information and numerical information. There was a significant negative correlation between numeracy and the level of processing of relevant comparative risk information (r(s) =-0.21, p < 0.01), indicating that low numerates processed the comparative risk information more deeply than the high numerates. There was no correlation between numeracy and perceived risk. These results add to previous experimental research, indicating that the smoking risk comparison was crucial for low numerates to evaluate and understand risk. Furthermore, the eye-tracker method is promising for studying information processing and improving risk communication formats. © 2011 Society for Risk Analysis.

  8. Gaze and visual search strategies of children with Asperger syndrome/high functioning autism viewing a magic trick.

    PubMed

    Joosten, Annette; Girdler, Sonya; Albrecht, Matthew A; Horlin, Chiara; Falkmer, Marita; Leung, Denise; Ordqvist, Anna; Fleischer, Håkan; Falkmer, Torbjörn

    2016-01-01

    To examine visual search patterns and strategies used by children with and without Asperger syndrome/high functioning autism (AS/HFA) while watching a magic trick. Limited responsivity to gaze cues is hypothesised to contribute to social deficits in children with AS/HFA. Twenty-one children with AS/HFA and 31 matched peers viewed a video of a gaze-cued magic trick twice. Between the viewings, they were informed about how the trick was performed. Participants' eye movements were recorded using a head-mounted eye-tracker. Children with AS/HFA looked less frequently and had shorter fixation on the magician's direct and averted gazes during both viewings and more frequently at not gaze-cued objects and on areas outside the magician's face. After being informed of how the trick was conducted, both groups made fewer fixations on gaze-cued objects and direct gaze. Information may enhance effective visual strategies in children with and without AS/HFA.

  9. Keeping your eyes on the prize: anger and visual attention to threats and rewards.

    PubMed

    Ford, Brett Q; Tamir, Maya; Brunyé, Tad T; Shirer, William R; Mahoney, Caroline R; Taylor, Holly A

    2010-08-01

    People's emotional states influence what they focus their attention on in their environment. For example, fear focuses people's attention on threats, whereas excitement may focus their attention on rewards. This study examined the effect of anger on overt visual attention to threats and rewards. Anger is an unpleasant emotion associated with approach motivation. If the effect of emotion on visual attention depends on valence, we would expect anger to focus people's attention on threats. If, however, the effect of emotion on visual attention depends on motivation, we would expect anger to focus people's attention on rewards. Using an eye tracker, we examined the effects of anger, fear, excitement, and a neutral emotional state on participants' overt visual attention to threatening, rewarding, and control images. We found that anger increased visual attention to rewarding information, but not to threatening information. These findings demonstrate that anger increases attention to potential rewards and suggest that the effects of emotions on visual attention are motivationally driven.

  10. Excimer Laser Surgery: Biometrical Iris Eye Recognition with Cyclorotational Control Eye Tracker System.

    PubMed

    Pajic, Bojan; Cvejic, Zeljka; Mijatovic, Zoran; Indjin, Dragan; Mueller, Joerg

    2017-05-25

    A prospective comparative study assessing the importance of the intra-operative dynamic rotational tracking-especially in the treatment of astigmatisms in corneal refractive Excimer laser correction-concerning clinical outcomes is presented. The cyclotorsion from upright to supine position was measured using iris image comparison. The Group 1 of patients was additionally treated with cyclorotational control and Group 2 only with X-Y control. Significant differences were observed between the groups regarding the mean postoperative cylinder refraction ( p < 0.05). The mean cyclotorsion can be calculated to 3.75° with a standard deviation of 3.1°. The total range of torsion was from -14.9° to +12.6°. Re-treatment rate was 2.2% in Group 1 and 8.2% in Group 2, which is highly significant ( p < 0.01). The investigation confirms that the dynamic rotational tracking system used for LASIK results in highly predictable refraction quality with significantly less postoperative re-treatments.

  11. Excimer Laser Surgery: Biometrical Iris Eye Recognition with Cyclorotational Control Eye Tracker System

    PubMed Central

    Pajic, Bojan; Cvejic, Zeljka; Mijatovic, Zoran; Indjin, Dragan; Mueller, Joerg

    2017-01-01

    A prospective comparative study assessing the importance of the intra-operative dynamic rotational tracking—especially in the treatment of astigmatisms in corneal refractive Excimer laser correction—concerning clinical outcomes is presented. The cyclotorsion from upright to supine position was measured using iris image comparison. The Group 1 of patients was additionally treated with cyclorotational control and Group 2 only with X-Y control. Significant differences were observed between the groups regarding the mean postoperative cylinder refraction (p < 0.05). The mean cyclotorsion can be calculated to 3.75° with a standard deviation of 3.1°. The total range of torsion was from −14.9° to +12.6°. Re-treatment rate was 2.2% in Group 1 and 8.2% in Group 2, which is highly significant (p < 0.01). The investigation confirms that the dynamic rotational tracking system used for LASIK results in highly predictable refraction quality with significantly less postoperative re-treatments. PMID:28587100

  12. Quantifying gaze and mouse interactions on spatial visual interfaces with a new movement analytics methodology

    PubMed Central

    2017-01-01

    Eye movements provide insights into what people pay attention to, and therefore are commonly included in a variety of human-computer interaction studies. Eye movement recording devices (eye trackers) produce gaze trajectories, that is, sequences of gaze location on the screen. Despite recent technological developments that enabled more affordable hardware, gaze data are still costly and time consuming to collect, therefore some propose using mouse movements instead. These are easy to collect automatically and on a large scale. If and how these two movement types are linked, however, is less clear and highly debated. We address this problem in two ways. First, we introduce a new movement analytics methodology to quantify the level of dynamic interaction between the gaze and the mouse pointer on the screen. Our method uses volumetric representation of movement, the space-time densities, which allows us to calculate interaction levels between two physically different types of movement. We describe the method and compare the results with existing dynamic interaction methods from movement ecology. The sensitivity to method parameters is evaluated on simulated trajectories where we can control interaction levels. Second, we perform an experiment with eye and mouse tracking to generate real data with real levels of interaction, to apply and test our new methodology on a real case. Further, as our experiment tasks mimics route-tracing when using a map, it is more than a data collection exercise and it simultaneously allows us to investigate the actual connection between the eye and the mouse. We find that there seem to be natural coupling when eyes are not under conscious control, but that this coupling breaks down when instructed to move them intentionally. Based on these observations, we tentatively suggest that for natural tracing tasks, mouse tracking could potentially provide similar information as eye-tracking and therefore be used as a proxy for attention. However, more research is needed to confirm this. PMID:28777822

  13. Quantifying gaze and mouse interactions on spatial visual interfaces with a new movement analytics methodology.

    PubMed

    Demšar, Urška; Çöltekin, Arzu

    2017-01-01

    Eye movements provide insights into what people pay attention to, and therefore are commonly included in a variety of human-computer interaction studies. Eye movement recording devices (eye trackers) produce gaze trajectories, that is, sequences of gaze location on the screen. Despite recent technological developments that enabled more affordable hardware, gaze data are still costly and time consuming to collect, therefore some propose using mouse movements instead. These are easy to collect automatically and on a large scale. If and how these two movement types are linked, however, is less clear and highly debated. We address this problem in two ways. First, we introduce a new movement analytics methodology to quantify the level of dynamic interaction between the gaze and the mouse pointer on the screen. Our method uses volumetric representation of movement, the space-time densities, which allows us to calculate interaction levels between two physically different types of movement. We describe the method and compare the results with existing dynamic interaction methods from movement ecology. The sensitivity to method parameters is evaluated on simulated trajectories where we can control interaction levels. Second, we perform an experiment with eye and mouse tracking to generate real data with real levels of interaction, to apply and test our new methodology on a real case. Further, as our experiment tasks mimics route-tracing when using a map, it is more than a data collection exercise and it simultaneously allows us to investigate the actual connection between the eye and the mouse. We find that there seem to be natural coupling when eyes are not under conscious control, but that this coupling breaks down when instructed to move them intentionally. Based on these observations, we tentatively suggest that for natural tracing tasks, mouse tracking could potentially provide similar information as eye-tracking and therefore be used as a proxy for attention. However, more research is needed to confirm this.

  14. Combining EEG and eye tracking: identification, characterization, and correction of eye movement artifacts in electroencephalographic data

    PubMed Central

    Plöchl, Michael; Ossandón, José P.; König, Peter

    2012-01-01

    Eye movements introduce large artifacts to electroencephalographic recordings (EEG) and thus render data analysis difficult or even impossible. Trials contaminated by eye movement and blink artifacts have to be discarded, hence in standard EEG-paradigms subjects are required to fixate on the screen. To overcome this restriction, several correction methods including regression and blind source separation have been proposed. Yet, there is no automated standard procedure established. By simultaneously recording eye movements and 64-channel-EEG during a guided eye movement paradigm, we investigate and review the properties of eye movement artifacts, including corneo-retinal dipole changes, saccadic spike potentials and eyelid artifacts, and study their interrelations during different types of eye- and eyelid movements. In concordance with earlier studies our results confirm that these artifacts arise from different independent sources and that depending on electrode site, gaze direction, and choice of reference these sources contribute differently to the measured signal. We assess the respective implications for artifact correction methods and therefore compare the performance of two prominent approaches, namely linear regression and independent component analysis (ICA). We show and discuss that due to the independence of eye artifact sources, regression-based correction methods inevitably over- or under-correct individual artifact components, while ICA is in principle suited to address such mixtures of different types of artifacts. Finally, we propose an algorithm, which uses eye tracker information to objectively identify eye-artifact related ICA-components (ICs) in an automated manner. In the data presented here, the algorithm performed very similar to human experts when those were given both, the topographies of the ICs and their respective activations in a large amount of trials. Moreover it performed more reliable and almost twice as effective than human experts when those had to base their decision on IC topographies only. Furthermore, a receiver operating characteristic (ROC) analysis demonstrated an optimal balance of false positive and false negative at an area under curve (AUC) of more than 0.99. Removing the automatically detected ICs from the data resulted in removal or substantial suppression of ocular artifacts including microsaccadic spike potentials, while the relevant neural signal remained unaffected. In conclusion the present work aims at a better understanding of individual eye movement artifacts, their interrelations and the respective implications for eye artifact correction. Additionally, the proposed ICA-procedure provides a tool for optimized detection and correction of eye movement-related artifact components. PMID:23087632

  15. The Modification of HOMER Software Application to Provide the United States Marine Corps with an Energy Planning Tool

    DTIC Science & Technology

    2012-12-01

    circuit used to discharge LiFePO4 batteries. .................84  Figure 33.  The PSPICE model of our constant current circuit...Ion Battery LiFePO4 Lithium Iron Phosphate xviii MEP Mobile Electric Power MP Maximum Power MPPT Maximum Power Point Tracker NASA National...GREENS). GREENS has eight large 200-W solar panels, four Lithium Iron Phosphate ( LiFePO4 ) batteries, and an integrated controller. GREENS is not

  16. Video-based eye tracking for neuropsychiatric assessment.

    PubMed

    Adhikari, Sam; Stark, David E

    2017-01-01

    This paper presents a video-based eye-tracking method, ideally deployed via a mobile device or laptop-based webcam, as a tool for measuring brain function. Eye movements and pupillary motility are tightly regulated by brain circuits, are subtly perturbed by many disease states, and are measurable using video-based methods. Quantitative measurement of eye movement by readily available webcams may enable early detection and diagnosis, as well as remote/serial monitoring, of neurological and neuropsychiatric disorders. We successfully extracted computational and semantic features for 14 testing sessions, comprising 42 individual video blocks and approximately 17,000 image frames generated across several days of testing. Here, we demonstrate the feasibility of collecting video-based eye-tracking data from a standard webcam in order to assess psychomotor function. Furthermore, we were able to demonstrate through systematic analysis of this data set that eye-tracking features (in particular, radial and tangential variance on a circular visual-tracking paradigm) predict performance on well-validated psychomotor tests. © 2017 New York Academy of Sciences.

  17. Eye Tracking Based Control System for Natural Human-Computer Interaction

    PubMed Central

    Lin, Shu-Fan

    2017-01-01

    Eye movement can be regarded as a pivotal real-time input medium for human-computer communication, which is especially important for people with physical disability. In order to improve the reliability, mobility, and usability of eye tracking technique in user-computer dialogue, a novel eye control system with integrating both mouse and keyboard functions is proposed in this paper. The proposed system focuses on providing a simple and convenient interactive mode by only using user's eye. The usage flow of the proposed system is designed to perfectly follow human natural habits. Additionally, a magnifier module is proposed to allow the accurate operation. In the experiment, two interactive tasks with different difficulty (searching article and browsing multimedia web) were done to compare the proposed eye control tool with an existing system. The Technology Acceptance Model (TAM) measures are used to evaluate the perceived effectiveness of our system. It is demonstrated that the proposed system is very effective with regard to usability and interface design. PMID:29403528

  18. Eye Tracking Based Control System for Natural Human-Computer Interaction.

    PubMed

    Zhang, Xuebai; Liu, Xiaolong; Yuan, Shyan-Ming; Lin, Shu-Fan

    2017-01-01

    Eye movement can be regarded as a pivotal real-time input medium for human-computer communication, which is especially important for people with physical disability. In order to improve the reliability, mobility, and usability of eye tracking technique in user-computer dialogue, a novel eye control system with integrating both mouse and keyboard functions is proposed in this paper. The proposed system focuses on providing a simple and convenient interactive mode by only using user's eye. The usage flow of the proposed system is designed to perfectly follow human natural habits. Additionally, a magnifier module is proposed to allow the accurate operation. In the experiment, two interactive tasks with different difficulty (searching article and browsing multimedia web) were done to compare the proposed eye control tool with an existing system. The Technology Acceptance Model (TAM) measures are used to evaluate the perceived effectiveness of our system. It is demonstrated that the proposed system is very effective with regard to usability and interface design.

  19. Remote quality assurance in cervical cancer screening in low resource settings using a handheld smartphone-based colposcope

    NASA Astrophysics Data System (ADS)

    Millien, Christophe; Jean-Baptiste, Meredith C.; Manite, Garçon; Levitz, David

    2015-03-01

    Cervical cancer is a leading cause of cancer death for women all across the developing world, where much of the infrastructure required for effective cervical cancer screening is unavailable because of limited resources. One of the most common method to screen for cervical cancer is by visual inspection with acetic acid (VIA), in which the cervix is imaged with the naked eye. Given inherent challenges in analysis and documentation when characterizing cervical tissue with the naked eye, an optical solution is needed. To address this challenge, a smartphone was modified and transformed into a mobile colposcope (a device used to image the cervix from outside) by adding a custom-fit light source and optics. The mobile smartphone colposcope was designed such that it augments VIA and easily integrates within the standard of care. The mobile smartphone colposcope is controlled by an app, which, stores cervical images captured on the mobile smartphone colposcope on a portal, enabling remote doctors to evaluate images and the treatment chosen by the health worker. Images from patients undergoing cervical cancer screening by a nurse using VIA in the University Hospital of Mirebalais (HUM) GYN outpatient clinic in Haiti were captured on the mobile smartphone colposcope. These images were later analyzed by an experienced OB/GYN at HUM, who determined whether or not the patient should be treated with cryoablation; more complicated cases were also shared with a consulting doctor in the US. The opinions of the experienced OB/GYN doctors at HUM, as well as the experts from the US, were used to educate nurses and midwives performing mobile colposcopy. These results suggest that remote assessment offered by mobile colposcopy can improve training of health workers performing VIA, and ultimately affect the therapy administered to patients.

  20. A pilot study on providing ophthalmic training to medical students while initiating a sustainable eye care effort for the underserved.

    PubMed

    Byrd, Julia M; Longmire, Michelle R; Syme, Noah P; Murray-Krezan, Cristina; Rose, Linda

    2014-03-01

    We present a method to reintroduce ophthalmic training into the medical school curriculum. To evaluate knowledge and skills acquired when participating in a service project, the Community Vision Project, and to develop a quantitative method for testing skills with the direct ophthalmoscope in patients. Second-year medical students participated in the study. After 1 month, their knowledge was compared with that of peers and graduates (internal medicine residents). Also at 1 month, their direct ophthalmoscope skills were compared with those of upperclassmen who had completed all core clerkships. One year later, after the participants had completed their core clerkships, long-term ophthalmoscope skills retention was tested, and their performance was compared with that of their classmates. Training occurred in mobile eye clinics. Knowledge and skills assessments were performed in the hospital eye clinic among students and residents at The University of New Mexico School of Medicine. Patients were recruited from the hospital eye clinic. Participants attended a 3-hour training session held by an attending physician in the hospital eye clinic and took part in at least 1 mobile eye clinic. A knowledge assessment quiz was administered to participants (n = 12), their classmates (n = 18), and internal medicine residents (n = 33). Skills assessment with the direct ophthalmoscope was performed at 1 month and at 1 year in 5 participants and 5 nonparticipants. Tonometer skills were assessed by comparing participants' readings with those of an ophthalmologist's obtained in patients at the mobile eye clinics. RESULTS Participants' median knowledge assessment scores were 48% higher than those of their classmates and 37% higher than those of internal medicine residents (P < .001 for both). Short-term (1 month) direct ophthalmoscopy median scores were 60% (quartile 1 to quartile 3 range, 40%-80%) for participants and 40% (quartile 1 to quartile 3 range, 20%-60%) for nonparticipating upperclassmen (P = .24). Long-term direct ophthalmoscopy median scores were 100% (quartile 1 to quartile 3 range, 75%-100%) for participants and 0% (quartile 1 to quartile 3 range, 0%-25%) for nonparticipating classmates (P = .11). Participants' tonometer readings were similar to those of the ophthalmologist's; their median reading was 2 mm Hg (quartile 1 to quartile 3 range, 0-4 mm Hg) higher than that of the ophthalmologist's (P = .05, sign test). Service-based learning offered an efficient model for incorporating ophthalmic training into the medical school curriculum. A viable tool for quantitatively testing ophthalmoscope skills is presented.

  1. An overview of human genetic privacy.

    PubMed

    Shi, Xinghua; Wu, Xintao

    2017-01-01

    The study of human genomics is becoming a Big Data science, owing to recent biotechnological advances leading to availability of millions of personal genome sequences, which can be combined with biometric measurements from mobile apps and fitness trackers, and of human behavior data monitored from mobile devices and social media. With increasing research opportunities for integrative genomic studies through data sharing, genetic privacy emerges as a legitimate yet challenging concern that needs to be carefully addressed, not only for individuals but also for their families. In this paper, we present potential genetic privacy risks and relevant ethics and regulations for sharing and protecting human genomics data. We also describe the techniques for protecting human genetic privacy from three broad perspectives: controlled access, differential privacy, and cryptographic solutions. © 2016 New York Academy of Sciences.

  2. Human eye haptics-based multimedia.

    PubMed

    Velandia, David; Uribe-Quevedo, Alvaro; Perez-Gutierrez, Byron

    2014-01-01

    Immersive and interactive multimedia applications offer complementary study tools in anatomy as users can explore 3D models while obtaining information about the organ, tissue or part being explored. Haptics increases the sense of interaction with virtual objects improving user experience in a more realistic manner. Common eye studying tools are books, illustrations, assembly models, and more recently these are being complemented with mobile apps whose 3D capabilities, computing power and customers are increasing. The goal of this project is to develop a complementary eye anatomy and pathology study tool using deformable models within a multimedia application, offering the students the opportunity for exploring the eye from up close and within with relevant information. Validation of the tool provided feedback on the potential of the development, along with suggestions on improving haptic feedback and navigation.

  3. Design and Experiment of Electrooculogram (EOG) System and Its Application to Control Mobile Robot

    NASA Astrophysics Data System (ADS)

    Sanjaya, W. S. M.; Anggraeni, D.; Multajam, R.; Subkhi, M. N.; Muttaqien, I.

    2017-03-01

    In this paper, we design and investigate a biological signal detection of eye movements (Electrooculogram). To detect a signal of Electrooculogram (EOG) used 4 instrument amplifier process; differential instrumentation amplifier, High Pass Filter (HPF) with 3 stage filters, Low Pass Filter (LPF) with 3 stage filters and Level Shifter circuit. The total of amplifying is 1000 times of gain, with frequency range 0.5-30 Hz. IC OP-Amp OP07 was used for all amplifying process. EOG signal will be read as analog input for Arduino microprocessor, and will interfaced with serial communication to PC Monitor using Processing® software. The result of this research show a differences value of eye movements. Differences signal of EOG have been applied to navigation control of the mobile robot. In this research, all communication process using Bluetooth HC-05.

  4. Optimizing virtual reality for all users through gaze-contingent and adaptive focus displays

    PubMed Central

    Padmanaban, Nitish; Konrad, Robert; Stramer, Tal; Wetzstein, Gordon

    2017-01-01

    From the desktop to the laptop to the mobile device, personal computing platforms evolve over time. Moving forward, wearable computing is widely expected to be integral to consumer electronics and beyond. The primary interface between a wearable computer and a user is often a near-eye display. However, current generation near-eye displays suffer from multiple limitations: they are unable to provide fully natural visual cues and comfortable viewing experiences for all users. At their core, many of the issues with near-eye displays are caused by limitations in conventional optics. Current displays cannot reproduce the changes in focus that accompany natural vision, and they cannot support users with uncorrected refractive errors. With two prototype near-eye displays, we show how these issues can be overcome using display modes that adapt to the user via computational optics. By using focus-tunable lenses, mechanically actuated displays, and mobile gaze-tracking technology, these displays can be tailored to correct common refractive errors and provide natural focus cues by dynamically updating the system based on where a user looks in a virtual scene. Indeed, the opportunities afforded by recent advances in computational optics open up the possibility of creating a computing platform in which some users may experience better quality vision in the virtual world than in the real one. PMID:28193871

  5. Workload assessment of surgeons: correlation between NASA TLX and blinks.

    PubMed

    Zheng, Bin; Jiang, Xianta; Tien, Geoffrey; Meneghetti, Adam; Panton, O Neely M; Atkins, M Stella

    2012-10-01

    Blinks are known as an indicator of visual attention and mental stress. In this study, surgeons' mental workload was evaluated utilizing a paper assessment instrument (National Aeronautics and Space Administration Task Load Index, NASA TLX) and by examining their eye blinks. Correlation between these two assessments was reported. Surgeons' eye motions were video-recorded using a head-mounted eye-tracker while the surgeons performed a laparoscopic procedure on a virtual reality trainer. Blink frequency and duration were computed using computer vision technology. The level of workload experienced during the procedure was reported by surgeons using the NASA TLX. A total of 42 valid videos were recorded from 23 surgeons. After blinks were computed, videos were divided into two groups based on the blink frequency: infrequent group (≤ 6 blinks/min) and frequent group (more than 6 blinks/min). Surgical performance (measured by task time and trajectories of tool tips) was not significantly different between these two groups, but NASA TLX scores were significantly different. Surgeons who blinked infrequently reported a higher level of frustration (46 vs. 34, P = 0.047) and higher overall level of workload (57 vs. 47, P = 0.045) than those who blinked more frequently. The correlation coefficients (Pearson test) between NASA TLX and the blink frequency and duration were -0.17 and 0.446. Reduction of blink frequency and shorter blink duration matched the increasing level of mental workload reported by surgeons. The value of using eye-tracking technology for assessment of surgeon mental workload was shown.

  6. Goal-directed visual attention drives health goal priming: An eye-tracking experiment.

    PubMed

    van der Laan, Laura N; Papies, Esther K; Hooge, Ignace T C; Smeets, Paul A M

    2017-01-01

    Several lab and field experiments have shown that goal priming interventions can be highly effective in promoting healthy food choices. Less is known, however, about the mechanisms by which goal priming affects food choice. This experiment tested the hypothesis that goal priming affects food choices through changes in visual attention. Specifically, it was hypothesized that priming with the dieting goal steers attention toward goal-relevant, low energy food products, which, in turn, increases the likelihood of choosing these products. In this eye-tracking experiment, 125 participants chose between high and low energy food products in a realistic online supermarket task while their eye movements were recorded with an eye-tracker. One group was primed with a health and dieting goal, a second group was exposed to a control prime, and a third group was exposed to no prime at all. The health goal prime increased low energy food choices and decreased high energy food choices. Furthermore, the health goal prime resulted in proportionally longer total dwell times on low energy food products, and this effect mediated the goal priming effect on choices. The findings suggest that the effect of priming on consumer choice may originate from an increase in attention for prime-congruent items. This study supports the effectiveness of health goal priming interventions in promoting healthy eating and opens up directions for research on other behavioral interventions that steer attention toward healthy foods. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  7. Expressing the sense of the House of Representatives that any conference committee or other meetings held to determine the content of national health care legislation be conducted in public under the watchful eye of the people of the United States.

    THOMAS, 111th Congress

    Rep. Buchanan, Vern [R-FL-13

    2009-10-20

    House - 01/13/2010 Motion to Discharge Committee filed by Mr. Buchanan. Petition No: 111-9. (All Actions) Notes: On 1/13/2010, a motion was filed to discharge the Committee on Rules from the consideration of H.Res.847. A discharge petition requires 218 signatures for further action. (Discharge Petition No. 111-9: text with signatures.) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  8. Infants’ Looking to Surprising Events: When Eye-Tracking Reveals More than Looking Time

    PubMed Central

    Yeung, H. Henny; Denison, Stephanie; Johnson, Scott P.

    2016-01-01

    Research on infants’ reasoning abilities often rely on looking times, which are longer to surprising and unexpected visual scenes compared to unsurprising and expected ones. Few researchers have examined more precise visual scanning patterns in these scenes, and so, here, we recorded 8- to 11-month-olds’ gaze with an eye tracker as we presented a sampling event whose outcome was either surprising, neutral, or unsurprising: A red (or yellow) ball was drawn from one of three visible containers populated 0%, 50%, or 100% with identically colored balls. When measuring looking time to the whole scene, infants were insensitive to the likelihood of the sampling event, replicating failures in similar paradigms. Nevertheless, a new analysis of visual scanning showed that infants did spend more time fixating specific areas-of-interest as a function of the event likelihood. The drawn ball and its associated container attracted more looking than the other containers in the 0% condition, but this pattern was weaker in the 50% condition, and even less strong in the 100% condition. Results suggest that measuring where infants look may be more sensitive than simply how much looking there is to the whole scene. The advantages of eye tracking measures over traditional looking measures are discussed. PMID:27926920

  9. Fish-eye view of MS Wolf on middeck

    NASA Image and Video Library

    2002-10-09

    STS112-309-008 (7-18 October 2002) --- Astronaut David A. Wolf, STS-112 mission specialist, is pictured near an Extravehicular Mobility Unit (EMU) space suit on the middeck of the Space Shuttle Atlantis.

  10. Eye movements during visual search in patients with glaucoma

    PubMed Central

    2012-01-01

    Background Glaucoma has been shown to lead to disability in many daily tasks including visual search. This study aims to determine whether the saccadic eye movements of people with glaucoma differ from those of people with normal vision, and to investigate the association between eye movements and impaired visual search. Methods Forty patients (mean age: 67 [SD: 9] years) with a range of glaucomatous visual field (VF) defects in both eyes (mean best eye mean deviation [MD]: –5.9 (SD: 5.4) dB) and 40 age-related people with normal vision (mean age: 66 [SD: 10] years) were timed as they searched for a series of target objects in computer displayed photographs of real world scenes. Eye movements were simultaneously recorded using an eye tracker. Average number of saccades per second, average saccade amplitude and average search duration across trials were recorded. These response variables were compared with measurements of VF and contrast sensitivity. Results The average rate of saccades made by the patient group was significantly smaller than the number made by controls during the visual search task (P = 0.02; mean reduction of 5.6% (95% CI: 0.1 to 10.4%). There was no difference in average saccade amplitude between the patients and the controls (P = 0.09). Average number of saccades was weakly correlated with aspects of visual function, with patients with worse contrast sensitivity (PR logCS; Spearman’s rho: 0.42; P = 0.006) and more severe VF defects (best eye MD; Spearman’s rho: 0.34; P = 0.037) tending to make less eye movements during the task. Average detection time in the search task was associated with the average rate of saccades in the patient group (Spearman’s rho = −0.65; P < 0.001) but this was not apparent in the controls. Conclusions The average rate of saccades made during visual search by this group of patients was fewer than those made by people with normal vision of a similar average age. There was wide variability in saccade rate in the patients but there was an association between an increase in this measure and better performance in the search task. Assessment of eye movements in individuals with glaucoma might provide insight into the functional deficits of the disease. PMID:22937814

  11. The Wills Eye Glaucoma App: Interest of Patients and Their Caregivers in a Smartphone-based and Tablet-based Glaucoma Application.

    PubMed

    Waisbourd, Michael; Dhami, Hermandeep; Zhou, Chen; Hsieh, Michael; Abichandani, Pramod; Pro, Michael J; Moster, Marlene R; Katz, L Jay; Hark, Lisa A; Myers, Jonathan S

    2016-09-01

    To evaluate the interest of glaucoma patients and their caregivers in a smartphone-based and tablet-based glaucoma application (App), developed by the Wills Eye Glaucoma Research Center in collaboration with Drexel University. Cross-sectional survey of patients with glaucoma and their caregivers. Main outcome measures are answers to survey questions regarding how receptive participants are to using the Glaucoma App. Fifty subjects completed the survey. The mean age (SD) was 59.5 (±17.3) years. A total of 88.6% of the participants lived in a household with access to a smartphone or tablet. The majority (72.3%) of participants would consider downloading the Glaucoma App, and younger participants (<65 y) were more likely to do so compared with their older (≥65 y) counterparts, P=0.025. Participants were more likely to download the App if it was free of charge, compared with a version that costs $3, P=0.018. Although only about one third (37.8%) of participants used eye drop reminders, nearly 3 of 4 (72.9%) participants were receptive to using the automated reminder feature of the Glaucoma App. Glaucoma patients and their caregivers were very interested in using a Glaucoma App; however, many were not willing to spend $3 for an App they seem to value. The free Wills Eye Glaucoma App currently available on the Apple store, includes educational videos, eye drop and appointment reminders, medical and ocular data storage, visual field tutorial, and intraocular pressure tracker. These features aim to increase patients' level of knowledge about glaucoma and improve their adherence to medication and follow-up appointment recommendations.

  12. Clinical outcomes of wavefront-guided laser in situ keratomileusis: 6-month follow-up.

    PubMed

    Aizawa, Daisuke; Shimizu, Kimiya; Komatsu, Mari; Ito, Misae; Suzuki, Masanobu; Ohno, Koji; Uozato, Hiroshi

    2003-08-01

    To evaluate the clinical outcomes 6 months after wavefront-guided laser in situ keratomileusis (LASIK) for myopia in Japan. Department of Ophthalmology, Sanno Hospital, Tokyo, Japan. This prospective study comprised 22 eyes of 12 patients treated with wavefront-guided LASIK who were available for evaluation at 6 months. The mean patient age was 31.2 years +/- 8.4 (SD) (range 23 to 50 years), and the mean preoperative spherical equivalent refraction was -7.30 +/- 2.72 diopters (D) (range -2.75 to -11.88 D). In all cases, preoperative wavefront analysis was performed with a Hartmann-Shack aberrometer and the Technolas 217z flying-spot excimer laser system (Bausch & Lomb) was used with 1.0 mm and 2.0 mm spot sizes and an active eye tracker with a 120 Hz tracking rate. The clinical outcomes of wavefront-guided LASIK were evaluated in terms of safety, efficacy, predictability, stability, complications, and preoperative and postoperative aberrations. At 6 months, 10 eyes had no change in best spectacle-correct visual acuity and 10 gained 1 or more lines. The safety index was 1.11 and the efficacy index, 0.82. Slight undercorrections were observed in highly myopic eyes. In all eyes, the postoperative refraction tended slightly toward myopia for 3 months and stabilized after that. No complication such as epithelial ingrowth, diffuse lamellar keratitis, or infection was observed. Comparison of the preoperative and postoperative aberrations showed that 2nd-order aberrations decreased and higher-order aberrations increased. In the 3rd order, aberrations increased in the high-myopia group (-6.0 D or worse) and decreased in the low to moderate-myopia group (better than -6.0 D). Wavefront-guided LASIK was a good option for refractive surgery, although a longer follow-up in a larger study is required.

  13. Chronic Organic Solvent Exposure Changes Visual Tracking in Men and Women.

    PubMed

    de Oliveira, Ana R; Campos Neto, Armindo de Arruda; Bezerra de Medeiros, Paloma C; de Andrade, Michael J O; Dos Santos, Natanael A

    2017-01-01

    Organic solvents can change CNS sensory and motor function. Eye-movement analyses can be important tools when investigating the neurotoxic changes that result from chronic organic solvent exposure. The current research measured the eye-movement patterns of men and women with and without histories of chronic organic solvent exposure. A total of 44 volunteers between 18 and 41 years old participated in this study; 22 were men (11 exposed and 11 controls), and 22 were women (11 exposed and 11 controls). Eye movement was evaluated using a 250-Hz High-Speed Video Eye Tracker Toolbox (Cambridge Research Systems) via an image of a maze. Specific body indices of exposed and non-exposed men and women were measured with an Inbody 720 to determine whether the differences in eye-movement patterns were associated with body composition. The data were analyzed using IBM SPSS Statistics version 20.0.0. The results indicated that exposed adults showed significantly more fixations ( t = 3.82; p = 0.001; r = 0.51) and longer fixations ( t = 4.27; p = 0.001, r = 0.54) than their non-exposed counterparts. Comparisons within men (e.g., exposed and non-exposed) showed significant differences in the number of fixations ( t = 2.21; p = 0.04; r = 0.20) and duration of fixations ( t = 3.29; p = 0.001; r = 0.35). The same was true for exposed vs. non-exposed women, who showed significant differences in the number of fixations ( t = 3.10; p = 0.001; r = 0.32) and fixation durations ( t = 2.76; p = 0.01; r = 0.28). However, the results did not show significant differences between exposed women and men in the number and duration of fixations. No correlations were found between eye-movement pattern and body composition measures ( p > 0.05). These results suggest that chronic organic solvent exposure affects eye movements, regardless of sex and body composition, and that eye tracking contributes to the investigation of the visual information processing disorders acquired by workers exposed to organic solvents.

  14. Species-specific differences in relative eye size are related to patterns of edge avoidance in an Amazonian rainforest bird community

    PubMed Central

    Martínez-Ortega, Cristina; Santos, Eduardo SA; Gil, Diego

    2014-01-01

    Eye size shows a large degree of variation among species, even after correcting for body size. In birds, relatively larger eyes have been linked to predation risk, capture of mobile prey, and nocturnal habits. Relatively larger eyes enhance visual acuity and also allow birds to forage and communicate in low-light situations. Complex habitats such as tropical rain forests provide a mosaic of diverse lighting conditions, including differences among forest strata and at different distances from the forest edge. We examined in an Amazonian forest bird community whether microhabitat occupancy (defined by edge avoidance and forest stratum) was a predictor of relative eye size. We found that relative eye size increased with edge avoidance, but did not differ according to forest stratum. Nevertheless, the relationship between edge avoidance and relative eye size showed a nonsignificant positive trend for species that inhabit lower forest strata. Our analysis shows that birds that avoid forest edges have larger eyes than those living in lighter parts. We expect that this adaptation may allow birds to increase their active daily period in dim areas of the forest. The pattern that we found raises the question of what factors may limit the evolution of large eyes. PMID:25614788

  15. A mobile system combining lidar and sunphotometer on-road measurements: description and first results

    NASA Astrophysics Data System (ADS)

    Popovici, Ioana; Goloub, Philippe; Podvin, Thierry; Blarel, Luc; Loisil, Rodrigue; Mortier, Augustin; Deroo, Christine; Ducos, Fabrice; Victori, Stéphane; Torres, Benjamin

    2018-04-01

    The mobile system described in this paper integrates a commercial eye-safe lidar (CIMEL), a sunphotometer and in situ instruments. The system is distinguished by other transportable platforms through its capabilities to perform onroad measurements. The potential of a commercial lidar to provide reliable information on aerosol properties is investigated through comparison with a multi-wavelength Raman lidar. First results from observation campaigns in northern France are presented.

  16. JAKE® Multimodal Data Capture System: Insights from an Observational Study of Autism Spectrum Disorder.

    PubMed

    Ness, Seth L; Manyakov, Nikolay V; Bangerter, Abigail; Lewin, David; Jagannatha, Shyla; Boice, Matthew; Skalkin, Andrew; Dawson, Geraldine; Janvier, Yvette M; Goodwin, Matthew S; Hendren, Robert; Leventhal, Bennett; Shic, Frederick; Cioccia, Walter; Pandina, Gahan

    2017-01-01

    Objective: To test usability and optimize the Janssen Autism Knowledge Engine (JAKE®) system's components, biosensors, and procedures used for objective measurement of core and associated symptoms of autism spectrum disorder (ASD) in clinical trials. Methods: A prospective, observational study of 29 children and adolescents with ASD using the JAKE system was conducted at three sites in the United States. This study was designed to establish the feasibility of the JAKE system and to learn practical aspects of its implementation. In addition to information collected by web and mobile components, wearable biosensor data were collected both continuously in natural settings and periodically during a battery of experimental tasks administered in laboratory settings. This study is registered at clinicaltrials.gov, NCT02299700. Results: Feedback collected throughout the study allowed future refinements to be planned for all components of the system. The Autism Behavior Inventory (ABI), a parent-reported measure of ASD core and associated symptoms, performed well. Among biosensors studied, the eye-tracker, sleep monitor, and electrocardiogram were shown to capture high quality data, whereas wireless electroencephalography was difficult to use due to its form factor. On an exit survey, the majority of parents rated their overall reaction to JAKE as positive/very positive. No significant device-related events were reported in the study. Conclusion: The results of this study, with the described changes, demonstrate that the JAKE system is a viable, useful, and safe platform for use in clinical trials of ASD, justifying larger validation and deployment studies of the optimized system.

  17. JAKE® Multimodal Data Capture System: Insights from an Observational Study of Autism Spectrum Disorder

    PubMed Central

    Ness, Seth L.; Manyakov, Nikolay V.; Bangerter, Abigail; Lewin, David; Jagannatha, Shyla; Boice, Matthew; Skalkin, Andrew; Dawson, Geraldine; Janvier, Yvette M.; Goodwin, Matthew S.; Hendren, Robert; Leventhal, Bennett; Shic, Frederick; Cioccia, Walter; Pandina, Gahan

    2017-01-01

    Objective: To test usability and optimize the Janssen Autism Knowledge Engine (JAKE®) system's components, biosensors, and procedures used for objective measurement of core and associated symptoms of autism spectrum disorder (ASD) in clinical trials. Methods: A prospective, observational study of 29 children and adolescents with ASD using the JAKE system was conducted at three sites in the United States. This study was designed to establish the feasibility of the JAKE system and to learn practical aspects of its implementation. In addition to information collected by web and mobile components, wearable biosensor data were collected both continuously in natural settings and periodically during a battery of experimental tasks administered in laboratory settings. This study is registered at clinicaltrials.gov, NCT02299700. Results: Feedback collected throughout the study allowed future refinements to be planned for all components of the system. The Autism Behavior Inventory (ABI), a parent-reported measure of ASD core and associated symptoms, performed well. Among biosensors studied, the eye-tracker, sleep monitor, and electrocardiogram were shown to capture high quality data, whereas wireless electroencephalography was difficult to use due to its form factor. On an exit survey, the majority of parents rated their overall reaction to JAKE as positive/very positive. No significant device-related events were reported in the study. Conclusion: The results of this study, with the described changes, demonstrate that the JAKE system is a viable, useful, and safe platform for use in clinical trials of ASD, justifying larger validation and deployment studies of the optimized system. PMID:29018317

  18. Active retroreflector to measure the rotational orientation in conjunction with a laser tracker

    NASA Astrophysics Data System (ADS)

    Hofherr, O.; Wachten, C.; Müller, C.; Reinecke, H.

    2012-10-01

    High precision optical non-contact position measurement is a key technology in modern engineering. Laser trackers (LT) can determine accurately x-y-z coordinates of passive retroreflectors. Next-generation systems answer the additional need to measure an object's rotational orientation (pitch, yaw, roll). These devices are based on photogrammetry or on enhanced retroreflectors. However, photogrammetry relies on camera systems and time-consuming image processing. Enhanced retroreflectors analyze the LT's beam but are restricted in roll angle measurements. Here we present an integrated laser based method to evaluate all six degrees of freedom. An active retroreflector directly analyzes its orientation to the LT's beam path by outcoupling laser light on detectors. A proof of concept prototype has been designed with a specified measuring range of 360° for roll angle measurements and +/-15° for pitch and yaw angle respectively. The prototype's optical design is inspired by a cat's eye retroreflector. First results are promising and further improvements are under development. We anticipate our method to facilitate simple and cost-effective six degrees of freedom measurements. Furthermore, for industrial applications wide customizations are possible, e.g. adaptation of measuring range, optimization of accuracy, and further system miniaturization.

  19. Human-machine interfaces based on EMG and EEG applied to robotic systems.

    PubMed

    Ferreira, Andre; Celeste, Wanderley C; Cheein, Fernando A; Bastos-Filho, Teodiano F; Sarcinelli-Filho, Mario; Carelli, Ricardo

    2008-03-26

    Two different Human-Machine Interfaces (HMIs) were developed, both based on electro-biological signals. One is based on the EMG signal and the other is based on the EEG signal. Two major features of such interfaces are their relatively simple data acquisition and processing systems, which need just a few hardware and software resources, so that they are, computationally and financially speaking, low cost solutions. Both interfaces were applied to robotic systems, and their performances are analyzed here. The EMG-based HMI was tested in a mobile robot, while the EEG-based HMI was tested in a mobile robot and a robotic manipulator as well. Experiments using the EMG-based HMI were carried out by eight individuals, who were asked to accomplish ten eye blinks with each eye, in order to test the eye blink detection algorithm. An average rightness rate of about 95% reached by individuals with the ability to blink both eyes allowed to conclude that the system could be used to command devices. Experiments with EEG consisted of inviting 25 people (some of them had suffered cases of meningitis and epilepsy) to test the system. All of them managed to deal with the HMI in only one training session. Most of them learnt how to use such HMI in less than 15 minutes. The minimum and maximum training times observed were 3 and 50 minutes, respectively. Such works are the initial parts of a system to help people with neuromotor diseases, including those with severe dysfunctions. The next steps are to convert a commercial wheelchair in an autonomous mobile vehicle; to implement the HMI onboard the autonomous wheelchair thus obtained to assist people with motor diseases, and to explore the potentiality of EEG signals, making the EEG-based HMI more robust and faster, aiming at using it to help individuals with severe motor dysfunctions.

  20. Driver distraction : eye glance analysis and conversation workload : [research brief].

    DOT National Transportation Integrated Search

    2015-11-01

    The objective of this project was to: : Assess the risk of performing a secondary task : while driving a commercial motor vehicle (CMV). : Better understand the relationship of conversation : workload and visual distraction during mobile : ph...

  1. Diffusion of the Digital Health Self-Tracking Movement in Canada: Results of a National Survey

    PubMed Central

    Leaver, Chad; Bourget, Claire

    2018-01-01

    Background With the ever-increasing availability of mobile apps, consumer wearables, and smart medical devices, more and more individuals are self-tracking and managing their personal health data. Objective The aim of this study was to investigate the diffusion of the digital self-tracking movement in Canada. It provides a comprehensive, yet detailed account of this phenomenon. It examines the profile of digital self-trackers, traditional self-trackers, and nontrackers, further investigating the primary motivations for self-tracking and reasons for nontracking; barriers to adoption of connected care technologies; users’ appreciation of their self-tracking devices, including what they perceive to be the main benefits; factors that influence people’s intention to continue using connected care technologies in the future; and the reasons for usage discontinuance. Methods We conducted an online survey with a sample of 4109 Canadian adults, one of the largest ever. To ensure a representative sample, quota method was used (gender, age), following stratification by region. The maximum margin of error is estimated at 1.6%, 19 times out of 20. Results Our findings reveal that 66.20% (2720/4109) of our respondents regularly self-track one or more aspects of their health. About one in 4 respondents (1014/4109, 24.68%) currently owns a wearable or smart medical device, and 57.20% (580/1014) use their devices on a regular basis for self-tracking purposes. Digital self-trackers are typically young or mature adults, healthy, employed, university educated, with an annual family income of over $80,000 CAD. The most popular reported device is the fitness tracker or smartwatch that can capture a range of parameters. Currently, mobile apps and digital self-tracking devices are mainly used to monitor physical activity (856/1669, 51.13%), nutrition (545/1669, 32.65%), sleep patterns (482/1669, 28.88%) and, to a much lesser extent, cardiovascular and pulmonary biomarkers (215/1669, 12.88%), medication intake (126/1669, 7.55%), and glucose level (79/1669, 4.73%). Most users of connected care technologies (481/580, 83.0%) are highly satisfied and 88.2% (511/580) intend to continue using their apps and devices in the future. A majority said smart digital devices have allowed them to maintain or improve their health condition (398/580, 68.5%) and to be better informed about their health in general (387/580, 66.6%). About 33.80% of our sample (1389/4109) is composed of people who do not monitor their health or well-being on a regular basis. Conclusions Our study shows an opportunity to advance the health of Canadians through connected care technologies. Our findings can be used to set baseline information for future research on the rise of digital health self-tracking and its impacts. Although the use of mobile apps, consumer wearables, and smart medical devices could potentially benefit the growing population of patients with chronic conditions, the question remains as to whether it will diffuse broadly beyond early adopters and across cost inequities. PMID:29720359

  2. Diffusion of the Digital Health Self-Tracking Movement in Canada: Results of a National Survey.

    PubMed

    Paré, Guy; Leaver, Chad; Bourget, Claire

    2018-05-02

    With the ever-increasing availability of mobile apps, consumer wearables, and smart medical devices, more and more individuals are self-tracking and managing their personal health data. The aim of this study was to investigate the diffusion of the digital self-tracking movement in Canada. It provides a comprehensive, yet detailed account of this phenomenon. It examines the profile of digital self-trackers, traditional self-trackers, and nontrackers, further investigating the primary motivations for self-tracking and reasons for nontracking; barriers to adoption of connected care technologies; users' appreciation of their self-tracking devices, including what they perceive to be the main benefits; factors that influence people's intention to continue using connected care technologies in the future; and the reasons for usage discontinuance. We conducted an online survey with a sample of 4109 Canadian adults, one of the largest ever. To ensure a representative sample, quota method was used (gender, age), following stratification by region. The maximum margin of error is estimated at 1.6%, 19 times out of 20. Our findings reveal that 66.20% (2720/4109) of our respondents regularly self-track one or more aspects of their health. About one in 4 respondents (1014/4109, 24.68%) currently owns a wearable or smart medical device, and 57.20% (580/1014) use their devices on a regular basis for self-tracking purposes. Digital self-trackers are typically young or mature adults, healthy, employed, university educated, with an annual family income of over $80,000 CAD. The most popular reported device is the fitness tracker or smartwatch that can capture a range of parameters. Currently, mobile apps and digital self-tracking devices are mainly used to monitor physical activity (856/1669, 51.13%), nutrition (545/1669, 32.65%), sleep patterns (482/1669, 28.88%) and, to a much lesser extent, cardiovascular and pulmonary biomarkers (215/1669, 12.88%), medication intake (126/1669, 7.55%), and glucose level (79/1669, 4.73%). Most users of connected care technologies (481/580, 83.0%) are highly satisfied and 88.2% (511/580) intend to continue using their apps and devices in the future. A majority said smart digital devices have allowed them to maintain or improve their health condition (398/580, 68.5%) and to be better informed about their health in general (387/580, 66.6%). About 33.80% of our sample (1389/4109) is composed of people who do not monitor their health or well-being on a regular basis. Our study shows an opportunity to advance the health of Canadians through connected care technologies. Our findings can be used to set baseline information for future research on the rise of digital health self-tracking and its impacts. Although the use of mobile apps, consumer wearables, and smart medical devices could potentially benefit the growing population of patients with chronic conditions, the question remains as to whether it will diffuse broadly beyond early adopters and across cost inequities. ©Guy Paré, Chad Leaver, Claire Bourget. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 02.05.2018.

  3. Growth Retardation Of Chick Embryo Exposed To A Low Dose Of Electromagnetic Waves.

    PubMed

    Siddiqi, Najam; John C, Muthusami; Norrish, Mark; Heming, Thomas

    2016-01-01

    The objectives of this study were to explore the effects of low dose of the nonionizing (REW) emitted by a mobile phone on the development of chick embryo. one hundred and twenty chick fertilized eggs were equally divided into a control and an exposed group. Sixty fertilized eggs were placed in an egg incubator with a mobile phone (SAR US: 1.10W/kg (head) 0.47 W/kg body) in silent mode having vibration disable mode. Mobile was called for a total of 20 minutes in 24 hours. Twenty embryos each were sacrificed at day 5, 10 and 15, mortality, wet body weight, head to rump length, eye diameter and morphological changes were noted. The control group, 60 eggs were incubated in the same conditions, having removed the phone. No mortality was noted. The experimental group exposed to REW showed subcutaneous haemorrhagic areas and significant growth retardation at day 10 as evidence by smaller eye diameter, wet weight and CR length than the control group. There were no significant growth differences at either day 5 or at day 15. Electromagnetic waves emitted from mobile phones even though for a very short duration of 20 minutes per day have affected the growth of the chick embryo at day 10 of incubation, Hence exposure of these waves are not 100% safe.

  4. Eye Size, Fovea, and Foraging Ecology in Accipitriform Raptors.

    PubMed

    Potier, Simon; Mitkus, Mindaugas; Bonadonna, Francesco; Duriez, Olivier; Isard, Pierre-François; Dulaurent, Thomas; Mentek, Marielle; Kelber, Almut

    2017-01-01

    Birds with larger eyes are predicted to have higher spatial resolution because of their larger retinal image. Raptors are well known for their acute vision, mediated by their deep central fovea. Because foraging strategies may demand specific visual adaptations, eye size and fovea may differ between species with different foraging ecology. We tested whether predators (actively hunting mobile prey) and carrion eaters (eating dead prey) from the order Accipitriformes differ in eye size, foveal depth, and retinal thickness using spectral domain optical coherence tomography and comparative phylogenetic methods. We found that (1) all studied predators (except one) had a central and a temporal fovea, but all carrion eaters had only the central fovea; (2) eye size scaled with body mass both in predators and carrion eaters; (3) predators had larger eyes relative to body mass and a thicker retina at the edge of the fovea than carrion eaters, but there was no difference in the depth of the central fovea between the groups. Finally, we found that (4) larger eyes generally had a deeper central fovea. These results suggest that the visual system of raptors within the order Accipitriformes may be highly adapted to the foraging strategy, except for the foveal depth, which seems mostly dependent upon the eye size. © 2017 S. Karger AG, Basel.

  5. Visual fields and eye morphology support color vision in a color-changing crab-spider.

    PubMed

    Insausti, Teresita C; Defrize, Jérémy; Lazzari, Claudio R; Casas, Jérôme

    2012-03-01

    Vision plays a major role in many spiders, being involved in prey hunting, orientation or substrate choice, among others. In Misumena vatia, which experiences morphological color changes, vision has been reported to be involved in substrate color matching. Electrophysiological evidence reveals that at least two types of photoreceptors are present in this species, but these data are not backed up by morphological evidence. This work analyzes the functional structure of the eyes of this spider and relates it to its color-changing abilities. A broad superposition of the visual field of the different eyes was observed, even between binocular regions of principal and secondary eyes. The frontal space is simultaneously analyzed by four eyes. This superposition supports the integration of the visual information provided by the different eye types. The mobile retina of the principal eyes of this spider is organized in three layers of three different types of rhabdoms. The third and deepest layer is composed by just one large rhabdom surrounded by dark screening pigments that limit the light entry. The three pairs of secondary eyes have all a single layer of rhabdoms. Our findings provide strong support for an involvement of the visual system in color matching in this spider. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Safety and durability of effect of contralateral-eye administration of AAV2 gene therapy in patients with childhood-onset blindness caused by RPE65 mutations: a follow-on phase 1 trial.

    PubMed

    Bennett, Jean; Wellman, Jennifer; Marshall, Kathleen A; McCague, Sarah; Ashtari, Manzar; DiStefano-Pappas, Julie; Elci, Okan U; Chung, Daniel C; Sun, Junwei; Wright, J Fraser; Cross, Dominique R; Aravand, Puya; Cyckowski, Laura L; Bennicelli, Jeannette L; Mingozzi, Federico; Auricchio, Alberto; Pierce, Eric A; Ruggiero, Jason; Leroy, Bart P; Simonelli, Francesca; High, Katherine A; Maguire, Albert M

    2016-08-13

    Safety and efficacy have been shown in a phase 1 dose-escalation study involving a unilateral subretinal injection of a recombinant adeno-associated virus (AAV) vector containing the RPE65 gene (AAV2-hRPE65v2) in individuals with inherited retinal dystrophy caused by RPE65 mutations. This finding, along with the bilateral nature of the disease and intended use in treatment, prompted us to determine the safety of administration of AAV2-hRPE65v2 to the contralateral eye in patients enrolled in the phase 1 study. In this follow-on phase 1 trial, one dose of AAV2-hRPE65v2 (1.5 × 10(11) vector genomes) in a total volume of 300 μL was subretinally injected into the contralateral, previously uninjected, eyes of 11 children and adults (aged 11-46 years at second administration) with inherited retinal dystrophy caused by RPE65 mutations, 1.71-4.58 years after the initial subretinal injection. We assessed safety, immune response, retinal and visual function, functional vision, and activation of the visual cortex from baseline until 3 year follow-up, with observations ongoing. This study is registered with ClinicalTrials.gov, number NCT01208389. No adverse events related to the AAV were reported, and those related to the procedure were mostly mild (dellen formation in three patients and cataracts in two). One patient developed bacterial endophthalmitis and was excluded from analyses. We noted improvements in efficacy outcomes in most patients without significant immunogenicity. Compared with baseline, pooled analysis of ten participants showed improvements in mean mobility and full-field light sensitivity in the injected eye by day 30 that persisted to year 3 (mobility p=0.0003, white light full-field sensitivity p<0.0001), but no significant change was seen in the previously injected eyes over the same time period (mobility p=0.7398, white light full-field sensitivity p=0.6709). Changes in visual acuity from baseline to year 3 were not significant in pooled analysis in the second eyes or the previously injected eyes (p>0.49 for all time-points compared with baseline). To our knowledge, AAV2-hRPE65v2 is the first successful gene therapy administered to the contralateral eye. The results highlight the use of several outcome measures and help to delineate the variables that contribute to maximal benefit from gene augmentation therapy in this disease. Center for Cellular and Molecular Therapeutics at The Children's Hospital of Philadelphia, Spark Therapeutics, US National Institutes of Health, Foundation Fighting Blindness, Institute for Translational Medicine and Therapeutics, Research to Prevent Blindness, Center for Advanced Retinal and Ocular Therapeutics, Mackall Foundation Trust, F M Kirby Foundation, and The Research Foundation-Flanders. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Safety and durability of effect of contralateral-eye administration of AAV2 gene therapy in patients with childhood-onset blindness caused by RPE65 mutatons: a follow-on phase 1 trial

    PubMed Central

    Bennett, Jean; Wellman, Jennifer; Marshall, Kathleen A; McCague, Sarah; Ashtari, Manzar; DiStefano-Pappas, Julie; Elci, Okan U; Chung, Daniel C; Sun, Junwei; Wright, J Fraser; Cross, Dominique R; Aravand, Puya; Cyckowski, Laura L; Bennicelli, Jeannette L; Mingozzi, Federico; Auricchio, Alberto; Pierce, Eric A; Ruggiero, Jason; Leroy, Bart P; Simonelli, Francesca; High, Katherine A; Maguire, Albert M

    2017-01-01

    Summary Background Safety and efficacy have been shown in a phase 1 dose-escalation study involving a unilateral subretinal injection of a recombinant adeno-associated virus (AAV) vector containing the RPE65 gene (AAV2-hRPE65v2) in individuals with inherited retinal dystrophy caused by RPE65 mutations. This finding, along with the bilateral nature of the disease and intended use in treatment, prompted us to determine the safety of administration of AAV2-hRPE65v2 to the contralateral eye in patients enrolled in the phase 1 study. Methods In this follow-on phase 1 trial, one dose of AAV2-hRPE65v2 (1·5 × 1011 vector genomes) in a total volume of 300 μL was subretinally injected into the contralateral, previously uninjected, eyes of 11 children and adults (aged 11–46 years at second administration) with inherited retinal dystrophy caused by RPE65 mutations, 1·71–4·58 years after the initial subretinal injection. We assessed safety, immune response, retinal and visual function, functional vision, and activation of the visual cortex from baseline until 3 year follow-up, with observations ongoing. This study is registered with ClinicalTrials.gov, number NCT01208389. Findings No adverse events related to the AAV were reported, and those related to the procedure were mostly mild (dellen formation in three patients and cataracts in two). One patient developed bacterial endophthalmitis and was excluded from analyses. We noted improvements in efficacy outcomes in most patients without significant immunogenicity. Compared with baseline, pooled analysis of ten participants showed improvements in mean mobility and full-field light sensitivity in the injected eye by day 30 that persisted to year 3 (mobility p=0·0003, white light full-field sensitivity p<0·0001), but no significant change was seen in the previously injected eyes over the same time period (mobility p=0·7398, white light full-field sensitivity p=0·6709). Changes in visual acuity from baseline to year 3 were not significant in pooled analysis in the second eyes or the previously injected eyes (p>0·49 for all time-points compared with baseline). Interpretation To our knowledge, AAV2-hRPE65v2 is the first successful gene therapy administered to the contralateral eye. The results highlight the use of several outcome measures and help to delineate the variables that contribute to maximal benefit from gene augmentation therapy in this disease. Funding Center for Cellular and Molecular Therapeutics at The Children’s Hospital of Philadelphia, Spark Therapeutics, US National Institutes of Health, Foundation Fighting Blindness, Institute for Translational Medicine and Therapeutics, Research to Prevent Blindness, Center for Advanced Retinal and Ocular Therapeutics, Mackall Foundation Trust, F M Kirby Foundation, and The Research Foundation—Flanders. PMID:27375040

  8. Dual Oculometer System for Aviation Crew Assessment

    NASA Technical Reports Server (NTRS)

    Latorella, Kara; Ellis, Kyle K.; Lynn, William A.; Frasca, Dennis; Burdette, Daniel W.; Feigh, Charles T.; Douglas, Alan L.

    2010-01-01

    Oculometers, eye trackers, are a useful tool for ascertaining the manner in which pilots deploy visual attentional resources, and for assessing the degree to which stimuli capture attention exogenously. The aim of this effort was to obtain oculometer data comfortably, unobtrusively, reliably and with good spatial resolution over a standard B757-like flight deck for both individuals in a crew. We chose to implement two remote, 5-camera Smarteye systems which were crafted for this purpose to operate harmoniously. We present here the results of validation exercises, lessons learned for improving data quality, and initial thoughts on the use of paired oculometer data to reflect crew workload, coordination, and situation awareness, in the aggregate.

  9. Spontaneous belief attribution in younger siblings of children on the autism spectrum.

    PubMed

    Gliga, Teodora; Senju, Atsushi; Pettinato, Michèle; Charman, Tony; Johnson, Mark H

    2014-03-01

    The recent development in the measurements of spontaneous mental state understanding, employing eye-movements instead of verbal responses, has opened new opportunities for understanding the developmental origin of "mind-reading" impairments frequently described in autism spectrum disorders (ASDs). Our main aim was to characterize the relationship between mental state understanding and the broader autism phenotype, early in childhood. An eye-tracker was used to capture anticipatory looking as a measure of false beliefs attribution in 3-year-old children with a family history of autism (at-risk participants, n = 47) and controls (control participants, n = 39). Unlike controls, the at-risk group, independent of their clinical outcome (ASD, broader autism phenotype or typically developing), performed at chance. Performance was not related to children's verbal or general IQ, nor was it explained by children "missing out" on crucial information, as shown by an analysis of visual scanning during the task. We conclude that difficulties with using mental state understanding for action prediction may be an endophenotype of autism spectrum disorders. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  10. Real-time tracking of visually attended objects in virtual environments and its application to LOD.

    PubMed

    Lee, Sungkil; Kim, Gerard Jounghyun; Choi, Seungmoon

    2009-01-01

    This paper presents a real-time framework for computationally tracking objects visually attended by the user while navigating in interactive virtual environments. In addition to the conventional bottom-up (stimulus-driven) saliency map, the proposed framework uses top-down (goal-directed) contexts inferred from the user's spatial and temporal behaviors, and identifies the most plausibly attended objects among candidates in the object saliency map. The computational framework was implemented using GPU, exhibiting high computational performance adequate for interactive virtual environments. A user experiment was also conducted to evaluate the prediction accuracy of the tracking framework by comparing objects regarded as visually attended by the framework to actual human gaze collected with an eye tracker. The results indicated that the accuracy was in the level well supported by the theory of human cognition for visually identifying single and multiple attentive targets, especially owing to the addition of top-down contextual information. Finally, we demonstrate how the visual attention tracking framework can be applied to managing the level of details in virtual environments, without any hardware for head or eye tracking.

  11. Self-motion perception: assessment by real-time computer-generated animations

    NASA Technical Reports Server (NTRS)

    Parker, D. E.; Phillips, J. O.

    2001-01-01

    We report a new procedure for assessing complex self-motion perception. In three experiments, subjects manipulated a 6 degree-of-freedom magnetic-field tracker which controlled the motion of a virtual avatar so that its motion corresponded to the subjects' perceived self-motion. The real-time animation created by this procedure was stored using a virtual video recorder for subsequent analysis. Combined real and illusory self-motion and vestibulo-ocular reflex eye movements were evoked by cross-coupled angular accelerations produced by roll and pitch head movements during passive yaw rotation in a chair. Contrary to previous reports, illusory self-motion did not correspond to expectations based on semicircular canal stimulation. Illusory pitch head-motion directions were as predicted for only 37% of trials; whereas, slow-phase eye movements were in the predicted direction for 98% of the trials. The real-time computer-generated animations procedure permits use of naive, untrained subjects who lack a vocabulary for reporting motion perception and is applicable to basic self-motion perception studies, evaluation of motion simulators, assessment of balance disorders and so on.

  12. Effect of Cellular Mobile Phone Use and Cetrizine on Hand-Eye Coordination and Visual Acuity.

    PubMed

    Gawit, Kalpita Ganpat; Tiwari, Smita Anand; Kasabe, Gauri Hari; Deshpande, Pradeep Kisanrao; Ghongane, Balasaheb Baburao

    2017-09-01

    Cellular mobile phones are a major cause of distraction especially while driving. The aggressive and inappropriate use of cellular mobile phones has increased the risk of accidents. Similar alerts are available in literature for certain substances and drugs (e.g. second generation anti H1 drug -Cetirizine) which also derange psychomotor performance and parameters of alertness. This study measured variations in hand-eye coordination and visual acuity due to use of cellular mobile phone in comparison to that of commonly used antihistaminic drug viz., single dose Cetirizine 10 mg. It was a single blind, single dose, interventional study, 100 healthy human volunteers divided into two groups. Baseline readings of all volunteers were noted. Group-I (n=50) was Cetirizine group (10mg orally stat), Group -II (n=50) Cellular mobile phone user group. Alertness was tested on hand- steadiness tester (Reaction Time Index = RTI) and on Flicker-fusion apparatus (visual acuity - Critical Flicker Fusion Frequency per second= CFFF/sec). Baseline readings of all volunteers were noted before intervention. Baseline was compared with readings at three hour post-intervention and was analysed by paired t-test. Inter-group comparison of parameters was also done and was analysed by unpaired t-test. The baseline RTI (95.46±41.74, 85.11±39.05) and CFF low and high (40.07±9.970, 40.76±9.309 and 40.42±9.035, 40.48±9.863) respectively, in Cetirizine group and Mobile user group were comparable. The RTI increased significantly (116.4±51.46, 102.8±49.26) in both the groups after intervention. However, there is no significant change in CFF intensity from baseline in either group post-intervention. Concurrent use of mobile phone while performing tasks, showed significant impairment of hand-steadiness which was comparable to that produced by single dose Cetirizine 10 mg and this may be one of the factors contributing to their close association with road traffic accidents.

  13. Intraocular and extraocular cameras for retinal prostheses: Effects of foveation by means of visual prosthesis simulation

    NASA Astrophysics Data System (ADS)

    McIntosh, Benjamin Patrick

    Blindness due to Age-Related Macular Degeneration and Retinitis Pigmentosa is unfortunately both widespread and largely incurable. Advances in visual prostheses that can restore functional vision in those afflicted by these diseases have evolved rapidly from new areas of research in ophthalmology and biomedical engineering. This thesis is focused on further advancing the state-of-the-art of both visual prostheses and implantable biomedical devices. A novel real-time system with a high performance head-mounted display is described that enables enhanced realistic simulation of intraocular retinal prostheses. A set of visual psychophysics experiments is presented using the visual prosthesis simulator that quantify, in several ways, the benefit of foveation afforded by an eye-pointed camera (such as an eye-tracked extraocular camera or an implantable intraocular camera) as compared with a head-pointed camera. A visual search experiment demonstrates a significant improvement in the time to locate a target on a screen when using an eye-pointed camera. A reach and grasp experiment demonstrates a 20% to 70% improvement in time to grasp an object when using an eye-pointed camera, with the improvement maximized when the percept is blurred. A navigation and mobility experiment shows a 10% faster walking speed and a 50% better ability to avoid obstacles when using an eye-pointed camera. Improvements to implantable biomedical devices are also described, including the design and testing of VLSI-integrable positive mobile ion contamination sensors and humidity sensors that can validate the hermeticity of biomedical device packages encapsulated by hermetic coatings, and can provide early warning of leaks or contamination that may jeopardize the implant. The positive mobile ion contamination sensors are shown to be sensitive to externally applied contamination. A model is proposed to describe sensitivity as a function of device geometry, and verified experimentally. Guidelines are provided on the use of spare CMOS oxide and metal layers to maximize the hermeticity of an implantable microchip. In addition, results are presented on the design and testing of small form factor, very low power, integrated CMOS clock generation circuits that are stable enough to drive commercial image sensor arrays, and therefore can be incorporated in an intraocular camera for retinal prostheses.

  14. Selective attention in peacocks during predator detection.

    PubMed

    Yorzinski, Jessica L; Platt, Michael L

    2014-05-01

    Predation can exert strong selective pressure on the evolution of behavioral and morphological traits in birds. Because predator avoidance is key to survival and birds rely heavily on visual perception, predation may have shaped avian visual systems as well. To address this question, we examined the role of visual attention in antipredator behavior in peacocks (Pavo cristatus). Peacocks were exposed to a model predator while their gaze was continuously recorded with a telemetric eye-tracker. We found that peacocks spent more time looking at and made more fixations on the predator compared to the same spatial location before the predator was revealed. The duration of fixations they directed toward conspecifics and environmental features decreased after the predator was revealed, indicating that the peacocks were rapidly scanning their environment with their eyes. Maximum eye movement amplitudes and amplitudes of consecutive saccades were similar before and after the predator was revealed. In cases where conspecifics detected the predator first, peacocks appeared to learn that danger was present by observing conspecifics' antipredator behavior. Peacocks were faster to detect the predator when they were fixating closer to the area where the predator would eventually appear. In addition, pupil size increased after predator exposure, consistent with increased physiological arousal. These findings demonstrate that peacocks selectively direct their attention toward predatory threats and suggest that predation has influenced the evolution of visual orienting systems.

  15. Displays enabling mobile multimedia

    NASA Astrophysics Data System (ADS)

    Kimmel, Jyrki

    2007-02-01

    With the rapid advances in telecommunications networks, mobile multimedia delivery to handsets is now a reality. While a truly immersive multimedia experience is still far ahead in the mobile world, significant advances have been made in the constituent audio-visual technologies to make this become possible. One of the critical components in multimedia delivery is the mobile handset display. While such alternatives as headset-style near-to-eye displays, autostereoscopic displays, mini-projectors, and roll-out flexible displays can deliver either a larger virtual screen size than the pocketable dimensions of the mobile device can offer, or an added degree of immersion by adding the illusion of the third dimension in the viewing experience, there are still challenges in the full deployment of such displays in real-life mobile communication terminals. Meanwhile, direct-view display technologies have developed steadily, and can provide a development platform for an even better viewing experience for multimedia in the near future. The paper presents an overview of the mobile display technology space with an emphasis on the advances and potential in developing direct-view displays further to meet the goal of enabling multimedia in the mobile domain.

  16. Integrating Social Media and Mobile Sensor Data for Clinical Decision Support: Concept and Requirements.

    PubMed

    Denecke, Kerstin

    2016-01-01

    Social media are increasingly used by individuals for the purpose of collecting data and reporting on the personal health status, on health issues, symptoms and experiences with treatments. Beyond, fitness trackers are more used by individuals to monitor their fitness and health. The health data that is becoming available due to these developments could provide a valuable source for continuous health monitoring, prevention of unexpected health events and clinical decision making since it gives insights into behavior and life habits. However, an integration of the data is challenging. This paper aims triggering the discussion about this current topic. We present a concept for integrating social media data with mobile sensor data and clinical data using digital patient modelling. Further, we collect requirements and challenges for a possible realization of the concept. Challenges include the data volume, reliability and semantic interoperability.

  17. Generic framework for vessel detection and tracking based on distributed marine radar image data

    NASA Astrophysics Data System (ADS)

    Siegert, Gregor; Hoth, Julian; Banyś, Paweł; Heymann, Frank

    2018-04-01

    Situation awareness is understood as a key requirement for safe and secure shipping at sea. The primary sensor for maritime situation assessment is still the radar, with the AIS being introduced as supplemental service only. In this article, we present a framework to assess the current situation picture based on marine radar image processing. Essentially, the framework comprises a centralized IMM-JPDA multi-target tracker in combination with a fully automated scheme for track management, i.e., target acquisition and track depletion. This tracker is conditioned on measurements extracted from radar images. To gain a more robust and complete situation picture, we are exploiting the aspect angle diversity of multiple marine radars, by fusing them a priori to the tracking process. Due to the generic structure of the proposed framework, different techniques for radar image processing can be implemented and compared, namely the BLOB detector and SExtractor. The overall framework performance in terms of multi-target state estimation will be compared for both methods based on a dedicated measurement campaign in the Baltic Sea with multiple static and mobile targets given.

  18. Computational modelling of temperature rises in the eye in the near field of radiofrequency sources at 380, 900 and 1800 MHz

    NASA Astrophysics Data System (ADS)

    Wainwright, P. R.

    2007-07-01

    This paper reports calculations of the temperature rises induced in the eye and lens by near-field exposure to radiation from communication handsets, using the finite difference time domain method and classical bioheat equation. Various models are compared, including the analytic solution for a sphere, a finite element model of an isolated eye and a modern model of the whole head. The role of the blood supply to the choroid in moderating temperature is discussed. Three different frequencies are considered, namely 380 MHz (used by TETRA), and 900 and 1800 MHz (used by GSM mobile phones). At 380 MHz, monopole and helical antennas are compared. An 'equivalent blood flow' is derived for the choroid in order to facilitate comparison of the whole head and isolated eye models. In the whole head model, the heating of the lens receives a significant contribution from energy absorbed outside the eye. The temperature rise in the lens is compared to the ICNIRP-recommended average specific energy absorption rate (SAR) and the SAR averaged over the eye alone. The temperature rise may reach 1.4 °C at the ICNIRP occupational exposure limit if an antenna is placed less than 24 mm from the eye and the exposure is sufficiently prolonged.

  19. Computational modelling of temperature rises in the eye in the near field of radiofrequency sources at 380, 900 and 1800 MHz.

    PubMed

    Wainwright, P R

    2007-06-21

    This paper reports calculations of the temperature rises induced in the eye and lens by near-field exposure to radiation from communication handsets, using the finite difference time domain method and classical bioheat equation. Various models are compared, including the analytic solution for a sphere, a finite element model of an isolated eye and a modern model of the whole head. The role of the blood supply to the choroid in moderating temperature is discussed. Three different frequencies are considered, namely 380 MHz (used by TETRA), and 900 and 1800 MHz (used by GSM mobile phones). At 380 MHz, monopole and helical antennas are compared. An 'equivalent blood flow' is derived for the choroid in order to facilitate comparison of the whole head and isolated eye models. In the whole head model, the heating of the lens receives a significant contribution from energy absorbed outside the eye. The temperature rise in the lens is compared to the ICNIRP-recommended average specific energy absorption rate (SAR) and the SAR averaged over the eye alone. The temperature rise may reach 1.4 degrees C at the ICNIRP occupational exposure limit if an antenna is placed less than 24 mm from the eye and the exposure is sufficiently prolonged.

  20. Gesturing during mental problem solving reduces eye movements, especially for individuals with lower visual working memory capacity.

    PubMed

    Pouw, Wim T J L; Mavilidi, Myrto-Foteini; van Gog, Tamara; Paas, Fred

    2016-08-01

    Non-communicative hand gestures have been found to benefit problem-solving performance. These gestures seem to compensate for limited internal cognitive capacities, such as visual working memory capacity. Yet, it is not clear how gestures might perform this cognitive function. One hypothesis is that gesturing is a means to spatially index mental simulations, thereby reducing the need for visually projecting the mental simulation onto the visual presentation of the task. If that hypothesis is correct, less eye movements should be made when participants gesture during problem solving than when they do not gesture. We therefore used mobile eye tracking to investigate the effect of co-thought gesturing and visual working memory capacity on eye movements during mental solving of the Tower of Hanoi problem. Results revealed that gesturing indeed reduced the number of eye movements (lower saccade counts), especially for participants with a relatively lower visual working memory capacity. Subsequent problem-solving performance was not affected by having (not) gestured during the mental solving phase. The current findings suggest that our understanding of gestures in problem solving could be improved by taking into account eye movements during gesturing.

  1. Attention and Recall of Point-of-sale Tobacco Marketing: A Mobile Eye-Tracking Pilot Study.

    PubMed

    Bansal-Travers, Maansi; Adkison, Sarah E; O'Connor, Richard J; Thrasher, James F

    2016-01-01

    As tobacco advertising restrictions have increased, the retail 'power wall' behind the counter is increasingly invaluable for marketing tobacco products. The primary objectives of this pilot study were 3-fold: (1) evaluate the attention paid/fixations on the area behind the cash register where tobacco advertising is concentrated and tobacco products are displayed in a real-world setting, (2) evaluate the duration (dwell-time) of these fixations, and (3) evaluate the recall of advertising displayed on the tobacco power wall. Data from 13 Smokers (S) and 12 Susceptible or non-daily Smokers (SS) aged 180-30 from a mobile eye-tracking study. Mobile-eye tracking technology records the orientation (fixation) and duration (dwell-time) of visual attention. Participants were randomized to one of three purchase tasks at a convenience store: Candy bar Only (CO; N = 10), Candy bar + Specified cigarette Brand (CSB; N = 6), and Candy bar + cigarette Brand of their Choice (CBC; N = 9). A post-session survey evaluated recall of tobacco marketing. Key outcomes were fixations and dwell-time on the cigarette displays at the point-of-sale. Participants spent a median time of 44 seconds during the standardized time evaluated and nearly three-quarters (72%) fixated on the power wall during their purchase, regardless of smoking status (S: 77%, SS: 67%) or purchase task (CO: 44%, CSB: 71%, CBC: 100%). In the post session survey, nearly all participants (96%) indicated they noticed a cigarette brand and 64% were able to describe a specific part of the tobacco wall or recall a promotional offer. Consumers are exposed to point-of-sale tobacco marketing, regardless of smoking status. FDA should consider regulations that limit exposure to point-of-sale tobacco marketing among consumers.

  2. The effect of age and sex on facial mimicry: a three-dimensional study in healthy adults.

    PubMed

    Sforza, C; Mapelli, A; Galante, D; Moriconi, S; Ibba, T M; Ferraro, L; Ferrario, V F

    2010-10-01

    To assess sex- and age-related characteristics in standardized facial movements, 40 healthy adults (20 men, 20 women; aged 20-50 years) performed seven standardized facial movements (maximum smile; free smile; "surprise" with closed mouth; "surprise" with open mouth; eye closure; right- and left-side eye closures). The three-dimensional coordinates of 21 soft tissue facial landmarks were recorded by a motion analyser, their movements computed, and asymmetry indices calculated. Within each movement, total facial mobility was independent from sex and age (analysis of variance, p>0.05). Asymmetry indices of the eyes and mouth were similar in both sexes (p>0.05). Age significantly influenced eye and mouth asymmetries of the right-side eye closure, and eye asymmetry of the surprise movement. On average, the asymmetry indices of the symmetric movements were always lower than 8%, and most did not deviate from the expected value of 0 (Student's t). Larger asymmetries were found for the asymmetric eye closures (eyes, up to 50%, p<0.05; mouth, up to 30%, p<0.05 only in the 20-30-year-old subjects). In conclusion, sex and age had a limited influence on total facial motion and asymmetry in normal adult men and women. Copyright © 2010 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Smartphone Applications for Amblyopia Treatment: A Review of Current Apps and Professional Involvement.

    PubMed

    Paudel, Nabin

    2018-01-18

    The objective of this study was to review games for amblyopia (lazy eye) that are commercially available in mobile applications (apps) stores and assess the involvement of eye care professionals in their development. The Google play store and the Apple iTunes store were searched in July 2017 and updated in September 2017 for amblyopia games using the terms amblyopia, lazy eye, amblyopia therapy, lazy eye therapy, lazy eye exercises, amblyopia exercises, lazy eye games, and amblyopia games. General ophthalmology or optometry apps and apps in languages other than English were excluded. A total of 42 games were identified, 12 Android only (28%), 20 iOS only (48%), and 10 (24%) both Android and iOS. Most of the games were available under the medical category (60%). Most of the games were released in 2015. The price of the games ranged from $0.00 to $32.00 (USD). Nearly half of the games (45%) were to be played binocularly either using red-green goggles (38%) or a virtual reality set (7%). Only 7% of the games had explicitly documented the involvement of eye care professionals during game development. Only one game (app) was developed in collaboration with a research group and a children's hospital. This study identified that most of the currently available games do not have eye care professional input. An establishment of the quality assurance by a body of qualified eye care professionals could enhance the confidence of patients and clinicians using the game.

  4. Sensing Technologies for Autism Spectrum Disorder Screening and Intervention

    PubMed Central

    Cabibihan, John-John; Javed, Hifza; Aldosari, Mohammed; Frazier, Thomas W.; Elbashir, Haitham

    2016-01-01

    This paper reviews the state-of-the-art in sensing technologies that are relevant for Autism Spectrum Disorder (ASD) screening and therapy. This disorder is characterized by difficulties in social communication, social interactions, and repetitive behaviors. It is diagnosed during the first three years of life. Early and intensive interventions have been shown to improve the developmental trajectory of the affected children. The earlier the diagnosis, the sooner the intervention therapy can begin, thus, making early diagnosis an important research goal. Technological innovations have tremendous potential to assist with early diagnosis and improve intervention programs. The need for careful and methodological evaluation of such emerging technologies becomes important in order to assist not only the therapists and clinicians in their selection of suitable tools, but to also guide the developers of the technologies in improving hardware and software. In this paper, we survey the literatures on sensing technologies for ASD and we categorize them into eye trackers, movement trackers, electrodermal activity monitors, tactile sensors, vocal prosody and speech detectors, and sleep quality assessment devices. We assess their effectiveness and study their limitations. We also examine the challenges faced by this growing field that need to be addressed before these technologies can perform up to their theoretical potential. PMID:28036004

  5. Saccade frequency response to visual cues during gait in Parkinson's disease: the selective role of attention.

    PubMed

    Stuart, Samuel; Lord, Sue; Galna, Brook; Rochester, Lynn

    2018-04-01

    Gait impairment is a core feature of Parkinson's disease (PD) with implications for falls risk. Visual cues improve gait in PD, but the underlying mechanisms are unclear. Evidence suggests that attention and vision play an important role; however, the relative contribution from each is unclear. Measurement of visual exploration (specifically saccade frequency) during gait allows for real-time measurement of attention and vision. Understanding how visual cues influence visual exploration may allow inferences of the underlying mechanisms to response which could help to develop effective therapeutics. This study aimed to examine saccade frequency during gait in response to a visual cue in PD and older adults and investigate the roles of attention and vision in visual cue response in PD. A mobile eye-tracker measured saccade frequency during gait in 55 people with PD and 32 age-matched controls. Participants walked in a straight line with and without a visual cue (50 cm transverse lines) presented under single task and dual-task (concurrent digit span recall). Saccade frequency was reduced when walking in PD compared to controls; however, visual cues ameliorated saccadic deficit. Visual cues significantly increased saccade frequency in both PD and controls under both single task and dual-task. Attention rather than visual function was central to saccade frequency and gait response to visual cues in PD. In conclusion, this study highlights the impact of visual cues on visual exploration when walking and the important role of attention in PD. Understanding these complex features will help inform intervention development. © 2018 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  6. Looking is buying. How visual attention and choice are affected by consumer preferences and properties of the supermarket shelf.

    PubMed

    Gidlöf, Kerstin; Anikin, Andrey; Lingonblad, Martin; Wallin, Annika

    2017-09-01

    There is a battle in the supermarket isle, a battle between what the consumer wants and what the retailer and others want her to see, and subsequently to buy. Product packages and displays contain a number of features and attributes tailored to catch consumers' attention. These are what we call external factors comprising the visual saliency, the number of facings, and the placement of each product. But a consumer also brings with her a number of goals and interests related to the products and their attributes. These are important internal factors, including brand preferences, price sensitivity, and dietary inclinations. We fit mobile eye trackers to consumers visiting real-life supermarkets in order to investigate to what extent external and internal factors affect consumers' visual attention and purchases. Both external and internal factors influenced what products consumers looked at, with a strong positive interaction between visual saliency and consumer preferences. Consumers appear to take advantage of visual saliency in their decision making, using their knowledge about products' appearance to guide their visual attention towards those that fit their preferences. When it comes to actual purchases, however, visual attention was by far the most important predictor, even after controlling for all other internal and external factors. In other words, the very act of looking longer or repeatedly at a package, for any reason, makes it more likely that this product will be bought. Visual attention is thus crucial for understanding consumer behaviour, even in the cluttered supermarket environment, but it cannot be captured by measurements of visual saliency alone. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Individual differences in face-looking behavior generalize from the lab to the world.

    PubMed

    Peterson, Matthew F; Lin, Jing; Zaun, Ian; Kanwisher, Nancy

    2016-05-01

    Recent laboratory studies have found large, stable individual differences in the location people first fixate when identifying faces, ranging from the brows to the mouth. Importantly, this variation is strongly associated with differences in fixation-specific identification performance such that individuals' recognition ability is maximized when looking at their preferred location (Mehoudar, Arizpe, Baker, & Yovel, 2014; Peterson & Eckstein, 2013). This finding suggests that face representations are retinotopic and individuals enact gaze strategies that optimize identification, yet the extent to which this behavior reflects real-world gaze behavior is unknown. Here, we used mobile eye trackers to test whether individual differences in face gaze generalize from lab to real-world vision. In-lab fixations were measured with a speeded face identification task, while real-world behavior was measured as subjects freely walked around the Massachusetts Institute of Technology campus. We found a strong correlation between the patterns of individual differences in face gaze in the lab and real-world settings. Our findings support the hypothesis that individuals optimize real-world face identification by consistently fixating the same location and thus strongly constraining the space of retinotopic input. The methods developed for this study entailed collecting a large set of high-definition, wide field-of-view natural videos from head-mounted cameras and the viewer's fixation position, allowing us to characterize subjects' actually experienced real-world retinotopic images. These images enable us to ask how vision is optimized not just for the statistics of the "natural images" found in web databases, but of the truly natural, retinotopic images that have landed on actual human retinae during real-world experience.

  8. Diagnostic features of feline restrictive orbital myofibroblastic sarcoma.

    PubMed

    Bell, C M; Schwarz, T; Dubielzig, R R

    2011-05-01

    A progressive debilitating disease of the orbit and adjacent connective tissues of cats has historically been called feline orbital pseudotumor. The authors reviewed clinical, histopathologic, and diagnostic imaging features of this disease in 12 cases from the Comparative Ocular Pathology Laboratory of Wisconsin. The cats' ages ranged from 7 to 16 years (mean, 10.8 years). All cats had a history of severely restricted mobility of the globe and eyelids with secondary corneal disease. Eleven cats (92%) had concurrent involvement of the contralateral eye and/or the oral cavity. Diffuse scleral or episcleral thickening was seen with computed tomography in all clinically affected eyes. Histologically, an insidious infiltration of neoplastic spindle cells in the orbit, eyelids, and periorbital skin and soft tissues, with collagen deposition and a few perivascular lymphocytes, led to entrapment and restricted mobility of the eyelids and orbital tissues. The tumor failed to form a discrete mass, and it spread along fascial planes to the contralateral orbit and eyelids and/or the lips and oral cavity. In all tested cases (n = 10), neoplastic cells were immunohistochemically positive for vimentin, S100 protein, and smooth muscle actin. The authors adopted the term feline restrictive orbital myofibroblastic sarcoma to reflect the restricted mobility of the eyelids and globe and the imaging and histologic features of an invasive yet low-grade myofibroblastic sarcoma.

  9. Mobilizing slit lamp to the field: A new affordable solution

    PubMed Central

    Farooqui, Javed Hussain; Jorgenson, Richard; Gomaa, Ahmed

    2015-01-01

    We are describing a simple and affordable design to pack and carry the slit lamp to the field. Orbis staff working on the Flying Eye Hospital (FEH) developed this design to facilitate mobilization of the slit lamp to the field during various FEH programs. The solution involves using a big toolbox, a central plywood apparatus, and foam. These supplies were cut to measure and used to support the slit lamp after being fitted snuggly in the box. This design allows easy and safe mobilization of the slit lamp to remote places. It was developed with the efficient use of space in mind and it can be easily reproduced in developing countries using same or similar supplies. Mobilizing slit lamp will be of great help for staff and institutes doing regular outreach clinical work. PMID:26669342

  10. Effect of viewing distance on the generation of vertical eye movements during locomotion

    NASA Technical Reports Server (NTRS)

    Moore, S. T.; Hirasaki, E.; Cohen, B.; Raphan, T.

    1999-01-01

    Vertical head and eye coordination was studied as a function of viewing distance during locomotion. Vertical head translation and pitch movements were measured using a video motion analysis system (Optotrak 3020). Vertical eye movements were recorded using a video-based pupil tracker (Iscan). Subjects (five) walked on a linear treadmill at a speed of 1.67 m/s (6 km/h) while viewing a target screen placed at distances ranging from 0.25 to 2.0 m at 0. 25-m intervals. The predominant frequency of vertical head movement was 2 Hz. In accordance with previous studies, there was a small head pitch rotation, which was compensatory for vertical head translation. The magnitude of the vertical head movements and the phase relationship between head translation and pitch were little affected by viewing distance, and tended to orient the naso-occipital axis of the head at a point approximately 1 m in front of the subject (the head fixation distance or HFD). In contrast, eye velocity was significantly affected by viewing distance. When viewing a far (2-m) target, vertical eye velocity was 180 degrees out of phase with head pitch velocity, with a gain of 0. 8. This indicated that the angular vestibulo-ocular reflex (aVOR) was generating the eye movement response. The major finding was that, at a close viewing distance (0.25 m), eye velocity was in phase with head pitch and compensatory for vertical head translation, suggesting that activation of the linear vestibulo-ocular reflex (lVOR) was contributing to the eye movement response. There was also a threefold increase in the magnitude of eye velocity when viewing near targets, which was consistent with the goal of maintaining gaze on target. The required vertical lVOR sensitivity to cancel an unmodified aVOR response and generate the observed eye velocity magnitude for near targets was almost 3 times that previously measured. Supplementary experiments were performed utilizing body-fixed active head pitch rotations at 1 and 2 Hz while viewing a head-fixed target. Results indicated that the interaction of smooth pursuit and the aVOR during visual suppression could modify both the gain and phase characteristics of the aVOR at frequencies encountered during locomotion. When walking, targets located closer than the HFD (1.0 m) would appear to move in the same direction as the head pitch, resulting in suppression of the aVOR. The results of the head-fixed target experiment suggest that phase modification of the aVOR during visual suppression could play a role in generating eye movements consistent with the goal of maintaining gaze on targets closer than the HFD, which would augment the lVOR response.

  11. Binocular lens tilt and decentration measurements in healthy subjects with phakic eyes.

    PubMed

    Schaeffel, Frank

    2008-05-01

    Tilt and decentration of the natural crystalline lens affect optical quality of the foveal image. However, little is known about the distributions of these variables in healthy subjects with phakic eyes and about their correlations in both eyes. A simple, portable, easy-to-use, and partially automated device was developed to study lens tilt and decentration in both eyes of 11 healthy subjects with phakic eyes. The first, third, and fourth Purkinje images (P1, P3, P4) were visualized using a single infrared (IR) light-emitting diode (LED), a planar lens (F = 85 mm; f/number of 1.4), and an infrared sensitive analog video camera. Software was developed to mark pupil edges and positions of P1, P4, and P3 with the cursor of the computer mouse, for three different gaze positions, and an automated regression analysis determined the gaze position that superimposed the third and fourth Purkinje images, the gaze direction for which the lens was oriented perpendicularly to the axis of the IR LED. In this position, lens decentration was determined as the linear distance of the superimposed P3/P4 positions from the pupil center. Contrary to previous approaches, a short initial fixation of a green LED with known angular position calibrated the device as a gaze tracker, and no further positional information was necessary on fixation targets. Horizontal and vertical kappa, horizontal and vertical lens tilt, and vertical lens decentration were highly correlated in both eyes of the subjects, whereas horizontal decentration of the lens was not. There was a large variability of kappa (average horizontal kappa -1.63 degrees +/- 1.77 degrees [left eyes] and +2.07 degrees +/- 2.68 degrees [right eyes]; average vertical kappa +2.52 degrees +/- 1.30 degrees [left eyes] and +2.77 degrees +/- 1.65 degrees [right eyes]). Standard deviation from three repeated measurements ranged from 0.28 degrees to 0.51 degrees for kappa, 0.36 degrees to 0.91 degrees for horizontal lens tilt, and 0.36 degrees to 0.48 degrees for vertical lens tilt. Decentration was measured with standard deviations ranging from 0.02 mm to 0.05 mm. All lenses were found tilted to the temporal side with respect to the fixation axis (on average by 4.6 degrees ). They were also decentered downward with respect to the pupil center by approximately 0.3 mm. Lens tilts and positions could be conveniently measured with the described portable device, a video camera with a large lens. That the lenses were tilted to the temporal side in both eyes, even if corrected for kappa, was unexpected. That they were displaced downward with respect to the pupil center could be related to gravity.

  12. Comparing the fixational and functional preferred retinal location in a pointing task

    PubMed Central

    Sullivan, Brian; Walker, Laura

    2016-01-01

    Patients with central vision loss (CVL) typically adopt eccentric viewing strategies using a preferred retinal locus (PRL) in peripheral retina. Clinically, the PRL is defined monocularly as the area of peripheral retina used to fixate small stimuli. It is not clear if this fixational PRL describes the same portion of peripheral retina used during dynamic binocular eye-hand coordination tasks. We studied this question with four participants each with a unique CVL history. Using a scanning laser ophthalmoscope, we measured participants’ monocular visual fields and the location and stability of their fixational PRLs. Participants’ monocular and binocular visual fields were also evaluated using a computer monitor and eye tracker. Lastly, eye-hand coordination was tested over several trials where participants pointed to and touched a small target on a touchscreen monitor. Trials were blocked and carried out monocularly and binocularly, with a target appearing at 5° or 15° from screen center, in one of 8 locations. During pointing, our participants often exhibited long movement durations, an increased number of eye movements and impaired accuracy, especially in monocular conditions. However, these compensatory changes in behavior did not consistently worsen when loci beyond the fixational PRL were used. While fixational PRL size, location and fixation stability provide a necessary description of behavior, they are not sufficient to capture the pointing PRL used in this task. Generally, patients use a larger portion of peripheral retina than one might expect from measures of the fixational PRL alone, when pointing to a salient target without time constraints. While the fixational and pointing PRLs often overlap, the fixational PRL does not predict the large area of peripheral retina that can be used. PMID:26440864

  13. Effects of combat training on visuomotor performance in children aged 9 to 12 years - an eye-tracking study.

    PubMed

    Ju, Yan-Ying; Liu, Yen-Hsiu; Cheng, Chih-Hsiu; Lee, Yu-Lung; Chang, Shih-Tsung; Sun, Chi-Chin; Cheng, Hsin-Yi Kathy

    2018-02-07

    Data on visuomotor performance in combat training and the effects of combat training on visuomotor performance are limited. This study aimed to investigate the effects of a specially designed combat sports (CS) training program on the visuomotor performance levels of children. A pre-post comparative design was implemented. A total of 26 students aged 9-12 years underwent 40-min CS training sessions twice a week for 8 weeks during their physical education classes. The CS training program was designed by a karate coach and a motor control specialist. The other 30 students continued their regular activities and were considered as a control group. Each student's eye movement was monitored using an eye tracker, whereas the motor performance was measured using a target hitting system with a program-controlled microprocessor. The measurements were taken 8 weeks before (baseline), 1 day before (pretest), and 1 week after (posttest) the designated training program. The task used for evaluating these students was hitting or tracking random illuminated targets as rapidly as possible. A two-way analysis of variance [group(2) × time(3)] with repeated measures of time was performed for statistical analysis. For the children who received combat training, although the eye response improvement was not significant, both the primary and secondary saccade onset latencies were significantly earlier compared to the children without combat training. Both groups of students exhibited improvement in their hit response times during the target hitting tasks. The current finding supported the notion that sports training efforts essentially enhance visuomotor function in children aged 9-12 years, and combat training facilitates an earlier secondary saccade onset.

  14. A Method to Quantify Visual Information Processing in Children Using Eye Tracking

    PubMed Central

    Kooiker, Marlou J.G.; Pel, Johan J.M.; van der Steen-Kant, Sanny P.; van der Steen, Johannes

    2016-01-01

    Visual problems that occur early in life can have major impact on a child's development. Without verbal communication and only based on observational methods, it is difficult to make a quantitative assessment of a child's visual problems. This limits accurate diagnostics in children under the age of 4 years and in children with intellectual disabilities. Here we describe a quantitative method that overcomes these problems. The method uses a remote eye tracker and a four choice preferential looking paradigm to measure eye movement responses to different visual stimuli. The child sits without head support in front of a monitor with integrated infrared cameras. In one of four monitor quadrants a visual stimulus is presented. Each stimulus has a specific visual modality with respect to the background, e.g., form, motion, contrast or color. From the reflexive eye movement responses to these specific visual modalities, output parameters such as reaction times, fixation accuracy and fixation duration are calculated to quantify a child's viewing behavior. With this approach, the quality of visual information processing can be assessed without the use of communication. By comparing results with reference values obtained in typically developing children from 0-12 years, the method provides a characterization of visual information processing in visually impaired children. The quantitative information provided by this method can be advantageous for the field of clinical visual assessment and rehabilitation in multiple ways. The parameter values provide a good basis to: (i) characterize early visual capacities and consequently to enable early interventions; (ii) compare risk groups and follow visual development over time; and (iii), construct an individual visual profile for each child. PMID:27500922

  15. A Method to Quantify Visual Information Processing in Children Using Eye Tracking.

    PubMed

    Kooiker, Marlou J G; Pel, Johan J M; van der Steen-Kant, Sanny P; van der Steen, Johannes

    2016-07-09

    Visual problems that occur early in life can have major impact on a child's development. Without verbal communication and only based on observational methods, it is difficult to make a quantitative assessment of a child's visual problems. This limits accurate diagnostics in children under the age of 4 years and in children with intellectual disabilities. Here we describe a quantitative method that overcomes these problems. The method uses a remote eye tracker and a four choice preferential looking paradigm to measure eye movement responses to different visual stimuli. The child sits without head support in front of a monitor with integrated infrared cameras. In one of four monitor quadrants a visual stimulus is presented. Each stimulus has a specific visual modality with respect to the background, e.g., form, motion, contrast or color. From the reflexive eye movement responses to these specific visual modalities, output parameters such as reaction times, fixation accuracy and fixation duration are calculated to quantify a child's viewing behavior. With this approach, the quality of visual information processing can be assessed without the use of communication. By comparing results with reference values obtained in typically developing children from 0-12 years, the method provides a characterization of visual information processing in visually impaired children. The quantitative information provided by this method can be advantageous for the field of clinical visual assessment and rehabilitation in multiple ways. The parameter values provide a good basis to: (i) characterize early visual capacities and consequently to enable early interventions; (ii) compare risk groups and follow visual development over time; and (iii), construct an individual visual profile for each child.

  16. Human agency beliefs influence behaviour during virtual social interactions.

    PubMed

    Caruana, Nathan; Spirou, Dean; Brock, Jon

    2017-01-01

    In recent years, with the emergence of relatively inexpensive and accessible virtual reality technologies, it is now possible to deliver compelling and realistic simulations of human-to-human interaction. Neuroimaging studies have shown that, when participants believe they are interacting via a virtual interface with another human agent, they show different patterns of brain activity compared to when they know that their virtual partner is computer-controlled. The suggestion is that users adopt an "intentional stance" by attributing mental states to their virtual partner. However, it remains unclear how beliefs in the agency of a virtual partner influence participants' behaviour and subjective experience of the interaction. We investigated this issue in the context of a cooperative "joint attention" game in which participants interacted via an eye tracker with a virtual onscreen partner, directing each other's eye gaze to different screen locations. Half of the participants were correctly informed that their partner was controlled by a computer algorithm ("Computer" condition). The other half were misled into believing that the virtual character was controlled by a second participant in another room ("Human" condition). Those in the "Human" condition were slower to make eye contact with their partner and more likely to try and guide their partner before they had established mutual eye contact than participants in the "Computer" condition. They also responded more rapidly when their partner was guiding them, although the same effect was also found for a control condition in which they responded to an arrow cue. Results confirm the influence of human agency beliefs on behaviour in this virtual social interaction context. They further suggest that researchers and developers attempting to simulate social interactions should consider the impact of agency beliefs on user experience in other social contexts, and their effect on the achievement of the application's goals.

  17. Presence of Contagious Yawning in Children with Autism Spectrum Disorder

    PubMed Central

    Kikuchi, Yukiko; Akechi, Hironori; Tojo, Yoshikuni; Osanai, Hiroo; Hasegawa, Toshikazu

    2013-01-01

    Most previous studies suggest diminished susceptibility to contagious yawning in children with autism spectrum disorder (ASD). However, it could be driven by their atypical attention to the face. To test this hypothesis, children with ASD and typically developing (TD) children were shown yawning and control movies. To ensure participants' attention to the face, an eye tracker controlled the onset of the yawning and control stimuli. Results demonstrated that both TD children and children with ASD yawned more frequently when they watched the yawning stimuli than the control stimuli. It is suggested therefore that the absence of contagious yawning in children with ASD, as reported in previous studies, might relate to their weaker tendency to spontaneously attend to others' faces. PMID:23970970

  18. The Developing Infant Creates a Curriculum for Statistical Learning.

    PubMed

    Smith, Linda B; Jayaraman, Swapnaa; Clerkin, Elizabeth; Yu, Chen

    2018-04-01

    New efforts are using head cameras and eye-trackers worn by infants to capture everyday visual environments from the point of view of the infant learner. From this vantage point, the training sets for statistical learning develop as the sensorimotor abilities of the infant develop, yielding a series of ordered datasets for visual learning that differ in content and structure between timepoints but are highly selective at each timepoint. These changing environments may constitute a developmentally ordered curriculum that optimizes learning across many domains. Future advances in computational models will be necessary to connect the developmentally changing content and statistics of infant experience to the internal machinery that does the learning. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Accurate or assumed: visual learning in children with ASD.

    PubMed

    Trembath, David; Vivanti, Giacomo; Iacono, Teresa; Dissanayake, Cheryl

    2015-10-01

    Children with autism spectrum disorder (ASD) are often described as visual learners. We tested this assumption in an experiment in which 25 children with ASD, 19 children with global developmental delay (GDD), and 17 typically developing (TD) children were presented a series of videos via an eye tracker in which an actor instructed them to manipulate objects in speech-only and speech + pictures conditions. We found no group differences in visual attention to the stimuli. The GDD and TD groups performed better when pictures were available, whereas the ASD group did not. Performance of children with ASD and GDD was positively correlated with visual attention and receptive language. We found no evidence of a prominent visual learning style in the ASD group.

  20. System and method for leveraging human physiological traits to control microprocessor frequency

    DOEpatents

    Shye, Alex; Pan, Yan; Scholbrock, Benjamin; Miller, J. Scott; Memik, Gokhan; Dinda, Peter A; Dick, Robert P

    2014-03-25

    A system and method for leveraging physiological traits to control microprocessor frequency are disclosed. In some embodiments, the system and method may optimize, for example, a particular processor-based architecture based on, for example, end user satisfaction. In some embodiments, the system and method may determine, for example, whether their users are satisfied to provide higher efficiency, improved reliability, reduced power consumption, increased security, and a better user experience. The system and method may use, for example, biometric input devices to provide information about a user's physiological traits to a computer system. Biometric input devices may include, for example, one or more of the following: an eye tracker, a galvanic skin response sensor, and/or a force sensor.

  1. Objective eye-gaze behaviour during face-to-face communication with proficient alaryngeal speakers: a preliminary study.

    PubMed

    Evitts, Paul; Gallop, Robert

    2011-01-01

    There is a large body of research demonstrating the impact of visual information on speaker intelligibility in both normal and disordered speaker populations. However, there is minimal information on which specific visual features listeners find salient during conversational discourse. To investigate listeners' eye-gaze behaviour during face-to-face conversation with normal, laryngeal and proficient alaryngeal speakers. Sixty participants individually participated in a 10-min conversation with one of four speakers (typical laryngeal, tracheoesophageal, oesophageal, electrolaryngeal; 15 participants randomly assigned to one mode of speech). All speakers were > 85% intelligible and were judged to be 'proficient' by two certified speech-language pathologists. Participants were fitted with a head-mounted eye-gaze tracking device (Mobile Eye, ASL) that calculated the region of interest and mean duration of eye-gaze. Self-reported gaze behaviour was also obtained following the conversation using a 10 cm visual analogue scale. While listening, participants viewed the lower facial region of the oesophageal speaker more than the normal or tracheoesophageal speaker. Results of non-hierarchical cluster analyses showed that while listening, the pattern of eye-gaze was predominantly directed at the lower face of the oesophageal and electrolaryngeal speaker and more evenly dispersed among the background, lower face, and eyes of the normal and tracheoesophageal speakers. Finally, results show a low correlation between self-reported eye-gaze behaviour and objective regions of interest data. Overall, results suggest similar eye-gaze behaviour when healthy controls converse with normal and tracheoesophageal speakers and that participants had significantly different eye-gaze patterns when conversing with an oesophageal speaker. Results are discussed in terms of existing eye-gaze data and its potential implications on auditory-visual speech perception. © 2011 Royal College of Speech & Language Therapists.

  2. Mobile Health Applications for Diabetes and Endocrinology: Promise and Peril?

    PubMed Central

    Eng, Donna S; Lee, Joyce M.

    2013-01-01

    We are in the midst of what some have called a “mobile health revolution”. Medical applications ("apps") for mobile phones are proliferating in the marketplace and clinicians are likely encountering patients with questions about the medical value of these apps. We conducted a review of medical apps focused on endocrine disease. We found a higher percentage of relevant apps in our searches of the iPhone app store compared with the Android marketplace. For our diabetes search in the iPhone store, the majority of apps (33%) focused on health tracking (blood sugars, insulin doses, carbohydrates), requiring manual entry of health data. Only two apps directly inputted blood sugars from glucometers attached to the mobile phone. The remainder of diabetes apps were teaching/training apps (22%), food reference databases (8%), social blogs/forums (5%), and physician directed apps (8%). We found a number of insulin dose calculator apps which technically meet criteria for being a medically regulated mobile application, but did not find evidence for FDA-approval despite their availability to consumers. Far fewer apps were focused on other endocrine disease and included medical reference for the field of endocrinology, access to endocrine journals, height predictors, medication trackers, and fertility apps. Although mobile health apps have great potential for improving chronic disease care, they face a number of challenges including lack of evidence of clinical effectiveness, lack of integration with the health care delivery system, the need for formal evaluation and review and organized searching for health apps, and potential threats to safety and privacy. PMID:23627878

  3. Retinal image quality and visual stimuli processing by simulation of partial eye cataract

    NASA Astrophysics Data System (ADS)

    Ozolinsh, Maris; Danilenko, Olga; Zavjalova, Varvara

    2016-10-01

    Visual stimuli were demonstrated on a 4.3'' mobile phone screen inside a "Virtual Reality" adapter that allowed separation of the left and right eye visual fields. Contrast of the retina image thus can be controlled by the image on the phone screen and parallel to that at appropriate geometry by the AC voltage applied to scattering PDLC cell inside the adapter. Such optical pathway separation allows to demonstrate to both eyes spatially variant images, that after visual binocular fusion acquire their characteristic indications. As visual stimuli we used grey and different color (two opponent components to vision - red-green in L*a*b* color space) spatially periodical stimuli for left and right eyes; and with spatial content that by addition or subtraction resulted as clockwise or counter clockwise slanted Gabor gratings. We performed computer modeling with numerical addition or subtraction of signals similar to processing in brain via stimuli input decomposition in luminance and color opponency components. It revealed the dependence of the perception psychophysical equilibrium point between clockwise or counter clockwise perception of summation on one eye image contrast and color saturation, and on the strength of the retinal aftereffects. Existence of a psychophysical equilibrium point in perception of summation is only in the presence of a prior adaptation to a slanted periodical grating and at the appropriate slant orientation of adaptation grating and/or at appropriate spatial grating pattern phase according to grating nods. Actual observer perception experiments when one eye images were deteriorated by simulated cataract approved the shift of mentioned psychophysical equilibrium point on the degree of artificial cataract. We analyzed also the mobile devices stimuli emission spectra paying attention to areas sensitive to macula pigments absorption spectral maxima and blue areas where the intense irradiation can cause in abnormalities in periodic melatonin regeneration and deviations in regular circadian rhythms. Therefore participants in vision studies using "Virtual Reality" appliances with fixed vision fields and emitting a spike liked spectral bands (on basis of OLED and AMOLED diodes) different from spectra of ambient illuminators should be accordingly warned about potential health risks.

  4. A reinterpretation of certain disorders affecting the eye muscles and their tissues

    PubMed Central

    Poonyathalang, Anuchit; Khanna, Sangeeta; Leigh, R John

    2007-01-01

    Recent discoveries about the orbital tissues prompt a re-evaluation of the way that clinicians think about disorders affecting the extraocular muscles, their nerves and motoneurons in the brainstem. The revolutionary discovery that the orbital layers of the extraocular muscles insert not onto the eyeball, but into fibromuscular pulleys that guide the orbital layers, provides explanations for the kinematic properties of eye rotations and clinical findings in some patients with strabismus. The demonstration that all extraocular fibers types, except pale global fibers, lack synaptic folding provides an explanation for why saccades may remain fast in patients with limited ocular mobility due to myasthenia gravis. More than one mechanism may account for the observation that patients with disorders affecting the eye muscles or their nerves can present with the appearance of central disorders of ocular motility, such as internuclear ophthalmoplegia. New approaches to analyzing saccades in patients with disjunctive eye movements provide the means to identify disorders affecting the peripheral or central components of the ocular motor system, or both. PMID:19668518

  5. Registration of Panoramic/Fish-Eye Image Sequence and LiDAR Points Using Skyline Features

    PubMed Central

    Zhu, Ningning; Jia, Yonghong; Ji, Shunping

    2018-01-01

    We propose utilizing a rigorous registration model and a skyline-based method for automatic registration of LiDAR points and a sequence of panoramic/fish-eye images in a mobile mapping system (MMS). This method can automatically optimize original registration parameters and avoid the use of manual interventions in control point-based registration methods. First, the rigorous registration model between the LiDAR points and the panoramic/fish-eye image was built. Second, skyline pixels from panoramic/fish-eye images and skyline points from the MMS’s LiDAR points were extracted, relying on the difference in the pixel values and the registration model, respectively. Third, a brute force optimization method was used to search for optimal matching parameters between skyline pixels and skyline points. In the experiments, the original registration method and the control point registration method were used to compare the accuracy of our method with a sequence of panoramic/fish-eye images. The result showed: (1) the panoramic/fish-eye image registration model is effective and can achieve high-precision registration of the image and the MMS’s LiDAR points; (2) the skyline-based registration method can automatically optimize the initial attitude parameters, realizing a high-precision registration of a panoramic/fish-eye image and the MMS’s LiDAR points; and (3) the attitude correction values of the sequences of panoramic/fish-eye images are different, and the values must be solved one by one. PMID:29883431

  6. There's an App for that!

    ERIC Educational Resources Information Center

    Dutton, Gail

    2011-01-01

    Important as training the sales force is, mobile training apps are being used for much more. Visual Eyes Inc., for example, has developed training apps for the U.S. military's combat medical teams that detail specific medical procedures, such as controlling hemorrhaging. Other apps, developed for corporations and government agencies, pass along…

  7. Bologna through Ontario Eyes: The Case of the Advanced Diploma in Architectural Technology

    ERIC Educational Resources Information Center

    Mitchell, Amy D.; Feltham, Mark; Trotter, Lane

    2015-01-01

    Inspired by Ontario's burgeoning interest in postsecondary student mobility, this article examines how elements of Europe's Bologna Process can help bridge the college--university divide of Ontario's postsecondary system. Via discourse analysis of relevant qualification frameworks and program standards, it argues that the current system…

  8. Hierarchical rank and women's organizational mobility: glass ceilings in corporate law firms.

    PubMed

    Gorman, Elizabeth H; Kmec, Julie A

    2009-03-01

    This article revives the debate over whether women's upward mobility prospects decline as they climb organizational hierarchies. Although this proposition is a core element of the "glass ceiling" metaphor, it has failed to gain strong support in previous research. The article establishes a firm theoretical foundation for expecting an increasing female disadvantage, with an eye toward defining the scope conditions and extending the model to upper-level external hires. The approach is illustrated in an empirical setting that meets the proposed scope conditions: corporate law firms in the United States. Results confirm that in this setting, the female mobility disadvantage is greater at higher organizational levels in the case of internal promotions, but not in the case of external hires.

  9. Is selective attention the basis for selective imitation in infants? An eye-tracking study of deferred imitation with 12-month-olds.

    PubMed

    Kolling, Thorsten; Oturai, Gabriella; Knopf, Monika

    2014-08-01

    Infants and children do not blindly copy every action they observe during imitation tasks. Research demonstrated that infants are efficient selective imitators. The impact of selective perceptual processes (selective attention) for selective deferred imitation, however, is still poorly described. The current study, therefore, analyzed 12-month-old infants' looking behavior during demonstration of two types of target actions: arbitrary versus functional actions. A fully automated remote eye tracker was used to assess infants' looking behavior during action demonstration. After a 30-min delay, infants' deferred imitation performance was assessed. Next to replicating a memory effect, results demonstrate that infants do imitate significantly more functional actions than arbitrary actions (functionality effect). Eye-tracking data show that whereas infants do not fixate significantly longer on functional actions than on arbitrary actions, amount of fixations and amount of saccades differ between functional and arbitrary actions, indicating different encoding mechanisms. In addition, item-level findings differ from overall findings, indicating that perceptual and conceptual item features influence looking behavior. Looking behavior on both the overall and item levels, however, does not relate to deferred imitation performance. Taken together, the findings demonstrate that, on the one hand, selective imitation is not explainable merely by selective attention processes. On the other hand, notwithstanding this reasoning, attention processes on the item level are important for encoding processes during target action demonstration. Limitations and future studies are discussed. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. How lay people understand and make sense of personalized disease risk information.

    PubMed

    Damman, Olga C; Bogaerts, Nina M M; van den Haak, Maaike J; Timmermans, Danielle R M

    2017-10-01

    Disease risk calculators are increasingly web-based, but previous studies have shown that risk information often poses problems for lay users. To examine how lay people understand the result derived from an online cardiometabolic risk calculator. A qualitative study was performed, using the risk calculator in the Dutch National Prevention Program for cardiometabolic diseases. The study consisted of three parts: (i) attention: completion of the risk calculator while an eye tracker registered eye movements; (ii) recall: completion of a recall task; and (iii) interpretation: participation in a semi-structured interview. We recruited people from the target population through an advertisement in a local newspaper; 16 people participated in the study, which took place in our university laboratory. Eye-tracking data showed that participants looked most extensively at numerical risk information. Percentages were recalled well, whereas natural frequencies and verbal labels were remembered less well. Five qualitative themes were derived from the interview data: (i) numerical information does not really sink in; (ii) the verbal categorical label made no real impact on people; (iii) people relied heavily on existing knowledge and beliefs; (iv) people zoomed in on risk factors, especially family history of diseases; and (v) people often compared their situation to that of their peers. Although people paid attention to and recalled the risk information to a certain extent, they seemed to have difficulty in properly using this information for interpreting their risk. © 2017 The Authors Health Expectations Published by John Wiley & Sons Ltd.

  11. Evaluation of helmet-mounted display targeting symbology based on eye tracking technology

    NASA Astrophysics Data System (ADS)

    Wang, Lijing; Wen, Fuzhen; Ma, Caixin; Zhao, Shengchu; Liu, Xiaodong

    2014-06-01

    The purpose of this paper is to find the Target Locator Lines (TLLs) which perform best by contrasting and comparing experiment based on three kinds of TTLs of fighter HMD. 10 university students, male, with an average age of 21-23, corrected visual acuity 1.5, participated in the experiment. In the experiment, head movement data was obtained by TrackIR. The geometric relationship between the coordinates of the real world and coordinates of the visual display was obtained by calculating the distance from viewpoint to midpoint of both eyes and the head movement data. Virtual helmet system simulation experiment environment was created by drawing TLLs of fighter HMD in the flight simulator visual scene. In the experiment, eye tracker was used to record the time and saccade trajectory. The results were evaluated by the duration of the time and saccade trajectory. The results showed that the symbol"locator line with digital vector length indication" cost most time and had the longest length of the saccade trajectory. It is the most ineffective and most unacceptable way. "Locator line with extending head vector length symbol" cost less time and had less length of the saccade trajectory. It is effective and acceptable;"Locator line with reflected vector length symbol" cost the least time and had the least length of the saccade trajectory. It is the most effective and most acceptable way. "Locator line with reflected vector length symbol" performs best. The results will provide reference value for the research of TTLs in future.

  12. Ultra-low-cost 3D gaze estimation: an intuitive high information throughput compliment to direct brain-machine interfaces

    NASA Astrophysics Data System (ADS)

    Abbott, W. W.; Faisal, A. A.

    2012-08-01

    Eye movements are highly correlated with motor intentions and are often retained by patients with serious motor deficiencies. Despite this, eye tracking is not widely used as control interface for movement in impaired patients due to poor signal interpretation and lack of control flexibility. We propose that tracking the gaze position in 3D rather than 2D provides a considerably richer signal for human machine interfaces by allowing direct interaction with the environment rather than via computer displays. We demonstrate here that by using mass-produced video-game hardware, it is possible to produce an ultra-low-cost binocular eye-tracker with comparable performance to commercial systems, yet 800 times cheaper. Our head-mounted system has 30 USD material costs and operates at over 120 Hz sampling rate with a 0.5-1 degree of visual angle resolution. We perform 2D and 3D gaze estimation, controlling a real-time volumetric cursor essential for driving complex user interfaces. Our approach yields an information throughput of 43 bits s-1, more than ten times that of invasive and semi-invasive brain-machine interfaces (BMIs) that are vastly more expensive. Unlike many BMIs our system yields effective real-time closed loop control of devices (10 ms latency), after just ten minutes of training, which we demonstrate through a novel BMI benchmark—the control of the video arcade game ‘Pong’.

  13. The Dept. of Energy Artificial Retina project

    ScienceCinema

    None

    2017-12-09

    LLNL has assisted in the development of the first long-term retinal prosthesis - called an artificial retina - that can function for years inside the harsh biological environment of the eye. This work has been done in collaboration with four national laboratories (Argonne, Los Alamos, Oak Ridge and Sandia), four universities (the California Institute of Technology, the Doheny Eye Institute at USC, North Carolina State University and the University of California, Santa Cruz), an industrial partner (Second Sight® Medical Products Inc. of Sylmar, Calif.) and the U.S. Department of Energy. With this device, application-specific integrated circuits transform digital images from a camera into electric signals in the eye that the brain uses to create a visual image. In clinical trials, patients with vision loss were able to successfully identify objects, increase mobility and detect movement using the artificial retina.

  14. Brief Report: Patterns of Eye Movements in Face to Face Conversation are Associated with Autistic Traits: Evidence from a Student Sample.

    PubMed

    Vabalas, Andrius; Freeth, Megan

    2016-01-01

    The current study investigated whether the amount of autistic traits shown by an individual is associated with viewing behaviour during a face-to-face interaction. The eye movements of 36 neurotypical university students were recorded using a mobile eye-tracking device. High amounts of autistic traits were neither associated with reduced looking to the social partner overall, nor with reduced looking to the face. However, individuals who were high in autistic traits exhibited reduced visual exploration during the face-to-face interaction overall, as demonstrated by shorter and less frequent saccades. Visual exploration was not related to social anxiety. This study suggests that there are systematic individual differences in visual exploration during social interactions and these are related to amount of autistic traits.

  15. Design and evaluation of Mina: a robotic orthosis for paraplegics.

    PubMed

    Neuhaus, Peter D; Noorden, Jerryll H; Craig, Travis J; Torres, Tecalote; Kirschbaum, Justin; Pratt, Jerry E

    2011-01-01

    Mobility options for persons suffering from paraplegia or paraparesis are limited to mainly wheeled devices. There are significant health, psychological, and social consequences related to being confined to a wheelchair. We present the Mina, a robotic orthosis for assisting mobility, which offers a legged mobility option for these persons. Mina is an overground robotic device that is worn on the back and around the legs to provide mobility assistance for people suffering from paraplegia or paraparesis. Mina uses compliant actuation to power the hip and knee joints. For paralyzed users, balance is provided with the assistance of forearm crutches. This paper presents the evaluation of Mina with two paraplegics (SCI ASIA-A). We confirmed that with a few hours of training and practice, Mina is currently able to provide paraplegics walking mobility at speeds of up to 0.20 m/s. We further confirmed that using Mina is not physically taxing and requires little cognitive effort, allowing the user to converse and maintain eye contact while walking. © 2011 IEEE

  16. Visual search accelerates during adolescence.

    PubMed

    Burggraaf, Rudolf; van der Geest, Jos N; Frens, Maarten A; Hooge, Ignace T C

    2018-05-01

    We studied changes in visual-search performance and behavior during adolescence. Search performance was analyzed in terms of reaction time and response accuracy. Search behavior was analyzed in terms of the objects fixated and the duration of these fixations. A large group of adolescents (N = 140; age: 12-19 years; 47% female, 53% male) participated in a visual-search experiment in which their eye movements were recorded with an eye tracker. The experiment consisted of 144 trials (50% with a target present), and participants had to decide whether a target was present. Each trial showed a search display with 36 Gabor patches placed on a hexagonal grid. The target was a vertically oriented element with a high spatial frequency. Nontargets differed from the target in spatial frequency, orientation, or both. Search performance and behavior changed during adolescence; with increasing age, fixation duration and reaction time decreased. Response accuracy, number of fixations, and selection of elements to fixate upon did not change with age. Thus, the speed of foveal discrimination increases with age, while the efficiency of peripheral selection does not change. We conclude that the way visual information is gathered does not change during adolescence, but the processing of visual information becomes faster.

  17. Visual attention to erotic images in women reporting pain with intercourse.

    PubMed

    Lykins, Amy D; Meana, Marta; Minimi, Jillian

    2011-01-01

    The coupling of sex and pain creates an interesting theoretical conundrum of clinical significance: Are women with dyspareunia distracted from sexual stimuli, or are they hypervigilant to sexual stimuli because these stimuli elicit thoughts and expectations of pain? This study measured attention to sexual stimuli in women reporting persistent pain with intercourse, women reporting low sexual desire, and women reporting no sexual problems. Participants viewed a series of erotic images, each containing an object intended to distract from the erotic scene regions, while an eye tracker recorded their eye movements. Women with pain looked for shorter periods of time and fewer times at the sexual scene region than did both women with low sexual desire (p = .024 and p = .018, respectively) and the no-dysfunction control group (p < .001 and p = .003, respectively). Women with pain also looked at the context (nonsexual) scene region significantly more times and for longer periods than did the no-dysfunction control women (p = .013 and p = .042, respectively). Results are interpreted to be potentially supportive of the cognitive distraction hypothesis associated with sexual dysfunction, with an additional component of cognitive avoidance of sexual stimuli for the women reporting sexual pain.

  18. A VidEo-Based Intelligent Recognition and Decision System for the Phacoemulsification Cataract Surgery.

    PubMed

    Tian, Shu; Yin, Xu-Cheng; Wang, Zhi-Bin; Zhou, Fang; Hao, Hong-Wei

    2015-01-01

    The phacoemulsification surgery is one of the most advanced surgeries to treat cataract. However, the conventional surgeries are always with low automatic level of operation and over reliance on the ability of surgeons. Alternatively, one imaginative scene is to use video processing and pattern recognition technologies to automatically detect the cataract grade and intelligently control the release of the ultrasonic energy while operating. Unlike cataract grading in the diagnosis system with static images, complicated background, unexpected noise, and varied information are always introduced in dynamic videos of the surgery. Here we develop a Video-Based Intelligent Recognitionand Decision (VeBIRD) system, which breaks new ground by providing a generic framework for automatically tracking the operation process and classifying the cataract grade in microscope videos of the phacoemulsification cataract surgery. VeBIRD comprises a robust eye (iris) detector with randomized Hough transform to precisely locate the eye in the noise background, an effective probe tracker with Tracking-Learning-Detection to thereafter track the operation probe in the dynamic process, and an intelligent decider with discriminative learning to finally recognize the cataract grade in the complicated video. Experiments with a variety of real microscope videos of phacoemulsification verify VeBIRD's effectiveness.

  19. A VidEo-Based Intelligent Recognition and Decision System for the Phacoemulsification Cataract Surgery

    PubMed Central

    Yin, Xu-Cheng; Wang, Zhi-Bin; Zhou, Fang; Hao, Hong-Wei

    2015-01-01

    The phacoemulsification surgery is one of the most advanced surgeries to treat cataract. However, the conventional surgeries are always with low automatic level of operation and over reliance on the ability of surgeons. Alternatively, one imaginative scene is to use video processing and pattern recognition technologies to automatically detect the cataract grade and intelligently control the release of the ultrasonic energy while operating. Unlike cataract grading in the diagnosis system with static images, complicated background, unexpected noise, and varied information are always introduced in dynamic videos of the surgery. Here we develop a Video-Based Intelligent Recognitionand Decision (VeBIRD) system, which breaks new ground by providing a generic framework for automatically tracking the operation process and classifying the cataract grade in microscope videos of the phacoemulsification cataract surgery. VeBIRD comprises a robust eye (iris) detector with randomized Hough transform to precisely locate the eye in the noise background, an effective probe tracker with Tracking-Learning-Detection to thereafter track the operation probe in the dynamic process, and an intelligent decider with discriminative learning to finally recognize the cataract grade in the complicated video. Experiments with a variety of real microscope videos of phacoemulsification verify VeBIRD's effectiveness. PMID:26693249

  20. System and method for calibrating inter-star-tracker misalignments in a stellar inertial attitude determination system

    NASA Technical Reports Server (NTRS)

    Li, Rongsheng (Inventor); Wu, Yeong-Wei Andy (Inventor); Hein, Douglas H. (Inventor)

    2004-01-01

    A method and apparatus for determining star tracker misalignments is disclosed. The method comprises the steps of defining a defining a reference frame for the star tracker assembly according to a boresight of the primary star tracker and a boresight of a second star tracker wherein the boresight of the primary star tracker and a plane spanned by the boresight of the primary star tracker and the boresight of the second star tracker at least partially define a datum for the reference frame for the star tracker assembly; and determining the misalignment of the at least one star tracker as a rotation of the defined reference frame.

  1. Using a fidget spinner to teach physics

    NASA Astrophysics Data System (ADS)

    Mesquita, Lucas; Brockington, Guilherme; Aline de Almeida, Pamella; Truyol, Maria Elena; André Testoni, Leonardo; Sousa, Paula F. F.

    2018-07-01

    In 2017, almost everywhere in the world, there was a boom in sales of fidget spinners. A toy that has ‘multi-lobes’ that can rotate freely from a thrust performed with the fingers. Thereby, we analysed the physics concepts that involved in this toy, such as angular and linear velocity. We did the analysis using the software Tracker, a laboratory light sensor, a free mobile application that turns the device flashlight into a strobe light source. Thus, we aim to show that it is possible to transform a well-known toy into an opportunity to work on physics concepts and to construct experiments in the classroom.

  2. Low-energy light bulbs, computers, tablets and the blue light hazard.

    PubMed

    O'Hagan, J B; Khazova, M; Price, L L A

    2016-02-01

    The introduction of low energy lighting and the widespread use of computer and mobile technologies have changed the exposure of human eyes to light. Occasional claims that the light sources with emissions containing blue light may cause eye damage raise concerns in the media. The aim of the study was to determine if it was appropriate to issue advice on the public health concerns. A number of sources were assessed and the exposure conditions were compared with international exposure limits, and the exposure likely to be received from staring at a blue sky. None of the sources assessed approached the exposure limits, even for extended viewing times.

  3. Popular Nutrition-Related Mobile Apps: A Feature Assessment

    PubMed Central

    Fallaize, Rosalind; Lovegrove, Julie A; Hwang, Faustina

    2016-01-01

    Background A key challenge in human nutrition is the assessment of usual food intake. This is of particular interest given recent proposals of eHealth personalized interventions. The adoption of mobile phones has created an opportunity for assessing and improving nutrient intake as they can be used for digitalizing dietary assessments and providing feedback. In the last few years, hundreds of nutrition-related mobile apps have been launched and installed by millions of users. Objective This study aims to analyze the main features of the most popular nutrition apps and to compare their strategies and technologies for dietary assessment and user feedback. Methods Apps were selected from the two largest online stores of the most popular mobile operating systems—the Google Play Store for Android and the iTunes App Store for iOS—based on popularity as measured by the number of installs and reviews. The keywords used in the search were as follows: calorie(s), diet, diet tracker, dietician, dietitian, eating, fit, fitness, food, food diary, food tracker, health, lose weight, nutrition, nutritionist, weight, weight loss, weight management, weight watcher, and ww calculator. The inclusion criteria were as follows: English language, minimum number of installs (1 million for Google Play Store) or reviews (7500 for iTunes App Store), relation to nutrition (ie, diet monitoring or recommendation), and independence from any device (eg, wearable) or subscription. Results A total of 13 apps were classified as popular for inclusion in the analysis. Nine apps offered prospective recording of food intake using a food diary feature. Food selection was available via text search or barcode scanner technologies. Portion size selection was only textual (ie, without images or icons). All nine of these apps were also capable of collecting physical activity (PA) information using self-report, the global positioning system (GPS), or wearable integrations. Their outputs focused predominantly on energy balance between dietary intake and PA. None of these nine apps offered features directly related to diet plans and motivational coaching. In contrast, the remaining four of the 13 apps focused on these opportunities, but without food diaries. One app—FatSecret—also had an innovative feature for connecting users with health professionals, and another—S Health—provided a nutrient balance score. Conclusions The high number of installs indicates that there is a clear interest and opportunity for diet monitoring and recommendation using mobile apps. All the apps collecting dietary intake used the same nutrition assessment method (ie, food diary record) and technologies for data input (ie, text search and barcode scanner). Emerging technologies, such as image recognition, natural language processing, and artificial intelligence, were not identified. None of the apps had a decision engine capable of providing personalized diet advice. PMID:27480144

  4. Popular Nutrition-Related Mobile Apps: A Feature Assessment.

    PubMed

    Franco, Rodrigo Zenun; Fallaize, Rosalind; Lovegrove, Julie A; Hwang, Faustina

    2016-08-01

    A key challenge in human nutrition is the assessment of usual food intake. This is of particular interest given recent proposals of eHealth personalized interventions. The adoption of mobile phones has created an opportunity for assessing and improving nutrient intake as they can be used for digitalizing dietary assessments and providing feedback. In the last few years, hundreds of nutrition-related mobile apps have been launched and installed by millions of users. This study aims to analyze the main features of the most popular nutrition apps and to compare their strategies and technologies for dietary assessment and user feedback. Apps were selected from the two largest online stores of the most popular mobile operating systems-the Google Play Store for Android and the iTunes App Store for iOS-based on popularity as measured by the number of installs and reviews. The keywords used in the search were as follows: calorie(s), diet, diet tracker, dietician, dietitian, eating, fit, fitness, food, food diary, food tracker, health, lose weight, nutrition, nutritionist, weight, weight loss, weight management, weight watcher, and ww calculator. The inclusion criteria were as follows: English language, minimum number of installs (1 million for Google Play Store) or reviews (7500 for iTunes App Store), relation to nutrition (ie, diet monitoring or recommendation), and independence from any device (eg, wearable) or subscription. A total of 13 apps were classified as popular for inclusion in the analysis. Nine apps offered prospective recording of food intake using a food diary feature. Food selection was available via text search or barcode scanner technologies. Portion size selection was only textual (ie, without images or icons). All nine of these apps were also capable of collecting physical activity (PA) information using self-report, the global positioning system (GPS), or wearable integrations. Their outputs focused predominantly on energy balance between dietary intake and PA. None of these nine apps offered features directly related to diet plans and motivational coaching. In contrast, the remaining four of the 13 apps focused on these opportunities, but without food diaries. One app-FatSecret-also had an innovative feature for connecting users with health professionals, and another-S Health-provided a nutrient balance score. The high number of installs indicates that there is a clear interest and opportunity for diet monitoring and recommendation using mobile apps. All the apps collecting dietary intake used the same nutrition assessment method (ie, food diary record) and technologies for data input (ie, text search and barcode scanner). Emerging technologies, such as image recognition, natural language processing, and artificial intelligence, were not identified. None of the apps had a decision engine capable of providing personalized diet advice.

  5. Very high frame rate volumetric integration of depth images on mobile devices.

    PubMed

    Kähler, Olaf; Adrian Prisacariu, Victor; Yuheng Ren, Carl; Sun, Xin; Torr, Philip; Murray, David

    2015-11-01

    Volumetric methods provide efficient, flexible and simple ways of integrating multiple depth images into a full 3D model. They provide dense and photorealistic 3D reconstructions, and parallelised implementations on GPUs achieve real-time performance on modern graphics hardware. To run such methods on mobile devices, providing users with freedom of movement and instantaneous reconstruction feedback, remains challenging however. In this paper we present a range of modifications to existing volumetric integration methods based on voxel block hashing, considerably improving their performance and making them applicable to tablet computer applications. We present (i) optimisations for the basic data structure, and its allocation and integration; (ii) a highly optimised raycasting pipeline; and (iii) extensions to the camera tracker to incorporate IMU data. In total, our system thus achieves frame rates up 47 Hz on a Nvidia Shield Tablet and 910 Hz on a Nvidia GTX Titan XGPU, or even beyond 1.1 kHz without visualisation.

  6. The Promise of Mobile Technology for Public Religious Education

    ERIC Educational Resources Information Center

    Daily, Eileen M.

    2013-01-01

    This article reviews the history of public religious education in the United States with an eye to its learning outcomes, contexts, and approaches. That history suggests that public religious education is still needed today but that informal learning contexts may be more appropriate than public schools. Recent trends in learning habits are then…

  7. Visual attention in egocentric field-of-view using RGB-D data

    NASA Astrophysics Data System (ADS)

    Olesova, Veronika; Benesova, Wanda; Polatsek, Patrik

    2017-03-01

    Most of the existing solutions predicting visual attention focus solely on referenced 2D images and disregard any depth information. This aspect has always represented a weak point since the depth is an inseparable part of the biological vision. This paper presents a novel method of saliency map generation based on results of our experiments with egocentric visual attention and investigation of its correlation with perceived depth. We propose a model to predict the attention using superpixel representation with an assumption that contrast objects are usually salient and have a sparser spatial distribution of superpixels than their background. To incorporate depth information into this model, we propose three different depth techniques. The evaluation is done on our new RGB-D dataset created by SMI eye-tracker glasses and KinectV2 device.

  8. The promise and peril of mobile health applications for diabetes and endocrinology.

    PubMed

    Eng, Donna S; Lee, Joyce M

    2013-06-01

    We are in the midst of what some have called a "mobile health revolution". Medical applications ("apps") for mobile phones are proliferating in the marketplace and clinicians are likely encountering patients with questions about the medical value of these apps. We conducted a review of medical apps focused on endocrine disease. We found a higher percentage of relevant apps in our searches of the iPhone app store compared with the Android marketplace. For our diabetes search in the iPhone store, the majority of apps (33%) focused on health tracking (blood sugars, insulin doses, carbohydrates), requiring manual entry of health data. Only two apps directly inputted blood sugars from glucometers attached to the mobile phone. The remainder of diabetes apps were teaching/training apps (22%), food reference databases (8%), social blogs/forums (5%), and physician directed apps (8%). We found a number of insulin dose calculator apps which technically meet criteria for being a medically regulated mobile application, but did not find evidence for FDA-approval despite their availability to consumers. Far fewer apps were focused on other endocrine disease and included medical reference for the field of endocrinology, access to endocrine journals, height predictors, medication trackers, and fertility apps. Although mobile health apps have great potential for improving chronic disease care, they face a number of challenges including lack of evidence of clinical effectiveness, lack of integration with the health care delivery system, the need for formal evaluation and review and organized searching for health apps, and potential threats to safety and privacy. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. iPhone applications for eye care professionals: a review of current capabilities and concerns.

    PubMed

    Cheng, Nicholas M; Chakrabarti, Rahul; Kam, Jonathan K

    2014-04-01

    To quantitatively review and categorize the eye care-related iPhone(®) (Apple(®), Cupertino, CA) applications ("apps") currently available, evaluate qualified professional involvement in app development, and suggest future needs in this emerging area of mobile health. The Apple iTunes(®) store was searched for iPhone eye care-themed apps using the general terms "ophthalmology," "ophthalmologist," "optometry," "optometrist," "eye care," and "ocular," in addition to terms based on the Centers for Disease Control and Prevention's common eye conditions. Data collected from each app included publication date, target audience, category of app, estimated number of downloads, average user rating, and documented involvement of qualified professionals. In total, 182 apps were identified. The majority of apps lacked community user ratings and had 3,000 or fewer downloads (84% and 69%, respectively). Consistent with other medical specialties, only 37% of apps had documented qualified professional involvement in their development. When stratified by intended audience, 52% and 44% of apps designed for ophthalmologists and optometrists, respectively, had professional input, compared with 31% for non-eye care clinicians and 21% for the general public. Smartphone apps are likely to become of increasingly greater relevance to the modern eye care professional with tremendous versatility in daily practice. However, despite the rapid emergence of eye care apps, a low level of qualified professional involvement in app development and a lack of peer review after publishing remain. There is a clear need for evidence-based principles and standards of app development to be adopted in this emerging area.

  10. Detection of third and sixth cranial nerve palsies with a novel method for eye tracking while watching a short film clip

    PubMed Central

    Samadani, Uzma; Farooq, Sameer; Ritlop, Robert; Warren, Floyd; Reyes, Marleen; Lamm, Elizabeth; Alex, Anastasia; Nehrbass, Elena; Kolecki, Radek; Jureller, Michael; Schneider, Julia; Chen, Agnes; Shi, Chen; Mendhiratta, Neil; Huang, Jason H.; Qian, Meng; Kwak, Roy; Mikheev, Artem; Rusinek, Henry; George, Ajax; Fergus, Robert; Kondziolka, Douglas; Huang, Paul P.; Smith, R. Theodore

    2015-01-01

    OBJECT Automated eye movement tracking may provide clues to nervous system function at many levels. Spatial calibration of the eye tracking device requires the subject to have relatively intact ocular motility that implies function of cranial nerves (CNs) III (oculomotor), IV (trochlear), and VI (abducent) and their associated nuclei, along with the multiple regions of the brain imparting cognition and volition. The authors have developed a technique for eye tracking that uses temporal rather than spatial calibration, enabling detection of impaired ability to move the pupil relative to normal (neurologically healthy) control volunteers. This work was performed to demonstrate that this technique may detect CN palsies related to brain compression and to provide insight into how the technique may be of value for evaluating neuropathological conditions associated with CN palsy, such as hydrocephalus or acute mass effect. METHODS The authors recorded subjects’ eye movements by using an Eyelink 1000 eye tracker sampling at 500 Hz over 200 seconds while the subject viewed a music video playing inside an aperture on a computer monitor. The aperture moved in a rectangular pattern over a fixed time period. This technique was used to assess ocular motility in 157 neurologically healthy control subjects and 12 patients with either clinical CN III or VI palsy confirmed by neuro-ophthalmological examination, or surgically treatable pathological conditions potentially impacting these nerves. The authors compared the ratio of vertical to horizontal eye movement (height/width defined as aspect ratio) in normal and test subjects. RESULTS In 157 normal controls, the aspect ratio (height/width) for the left eye had a mean value ± SD of 1.0117 ± 0.0706. For the right eye, the aspect ratio had a mean of 1.0077 ± 0.0679 in these 157 subjects. There was no difference between sexes or ages. A patient with known CN VI palsy had a significantly increased aspect ratio (1.39), whereas 2 patients with known CN III palsy had significantly decreased ratios of 0.19 and 0.06, respectively. Three patients with surgically treatable pathological conditions impacting CN VI, such as infratentorial mass effect or hydrocephalus, had significantly increased ratios (1.84, 1.44, and 1.34, respectively) relative to normal controls, and 6 patients with supratentorial mass effect had significantly decreased ratios (0.27, 0.53, 0.62, 0.45, 0.49, and 0.41, respectively). These alterations in eye tracking all reverted to normal ranges after surgical treatment of underlying pathological conditions in these 9 neurosurgical cases. CONCLUSIONS This proof of concept series of cases suggests that the use of eye tracking to detect CN palsy while the patient watches television or its equivalent represents a new capacity for this technology. It may provide a new tool for the assessment of multiple CNS functions that can potentially be useful in the assessment of awake patients with elevated intracranial pressure from hydrocephalus or trauma. PMID:25495739

  11. Detection of third and sixth cranial nerve palsies with a novel method for eye tracking while watching a short film clip.

    PubMed

    Samadani, Uzma; Farooq, Sameer; Ritlop, Robert; Warren, Floyd; Reyes, Marleen; Lamm, Elizabeth; Alex, Anastasia; Nehrbass, Elena; Kolecki, Radek; Jureller, Michael; Schneider, Julia; Chen, Agnes; Shi, Chen; Mendhiratta, Neil; Huang, Jason H; Qian, Meng; Kwak, Roy; Mikheev, Artem; Rusinek, Henry; George, Ajax; Fergus, Robert; Kondziolka, Douglas; Huang, Paul P; Smith, R Theodore

    2015-03-01

    Automated eye movement tracking may provide clues to nervous system function at many levels. Spatial calibration of the eye tracking device requires the subject to have relatively intact ocular motility that implies function of cranial nerves (CNs) III (oculomotor), IV (trochlear), and VI (abducent) and their associated nuclei, along with the multiple regions of the brain imparting cognition and volition. The authors have developed a technique for eye tracking that uses temporal rather than spatial calibration, enabling detection of impaired ability to move the pupil relative to normal (neurologically healthy) control volunteers. This work was performed to demonstrate that this technique may detect CN palsies related to brain compression and to provide insight into how the technique may be of value for evaluating neuropathological conditions associated with CN palsy, such as hydrocephalus or acute mass effect. The authors recorded subjects' eye movements by using an Eyelink 1000 eye tracker sampling at 500 Hz over 200 seconds while the subject viewed a music video playing inside an aperture on a computer monitor. The aperture moved in a rectangular pattern over a fixed time period. This technique was used to assess ocular motility in 157 neurologically healthy control subjects and 12 patients with either clinical CN III or VI palsy confirmed by neuro-ophthalmological examination, or surgically treatable pathological conditions potentially impacting these nerves. The authors compared the ratio of vertical to horizontal eye movement (height/width defined as aspect ratio) in normal and test subjects. In 157 normal controls, the aspect ratio (height/width) for the left eye had a mean value ± SD of 1.0117 ± 0.0706. For the right eye, the aspect ratio had a mean of 1.0077 ± 0.0679 in these 157 subjects. There was no difference between sexes or ages. A patient with known CN VI palsy had a significantly increased aspect ratio (1.39), whereas 2 patients with known CN III palsy had significantly decreased ratios of 0.19 and 0.06, respectively. Three patients with surgically treatable pathological conditions impacting CN VI, such as infratentorial mass effect or hydrocephalus, had significantly increased ratios (1.84, 1.44, and 1.34, respectively) relative to normal controls, and 6 patients with supratentorial mass effect had significantly decreased ratios (0.27, 0.53, 0.62, 0.45, 0.49, and 0.41, respectively). These alterations in eye tracking all reverted to normal ranges after surgical treatment of underlying pathological conditions in these 9 neurosurgical cases. This proof of concept series of cases suggests that the use of eye tracking to detect CN palsy while the patient watches television or its equivalent represents a new capacity for this technology. It may provide a new tool for the assessment of multiple CNS functions that can potentially be useful in the assessment of awake patients with elevated intracranial pressure from hydrocephalus or trauma.

  12. Barriers to pilot mobile teleophthalmology in a rural hospital in Southern Malawi.

    PubMed

    Pérez, Guillermo Martínez; Swart, Wayne; Munyenyembe, Jimmy Kondwani; Saranchuk, Peter

    2014-01-01

    Malawi has one of the highest HIV prevalences in Sub-Saharan Africa. The rate of eligible HIV-infected people being initiated on antiretroviral therapy (ART) and retained in HIV-care is currently far from adequate. Consequently, many people continue present with advanced immunosuppression at public health facilities, often with undiagnosed opportunistic infections (OIs). In this context, mHealth was the innovation chosen to assist Eye Clinical Officers in early diagnosis of HIV-related diseases having eye manifestations in a rural hospital in Thyolo, Southern Malawi. The mTeleophthalmology program began in October 2013, but was stopped prematurely due to organizational and technological barriers that compromised its feasibility. Sharing these barriers might be useful to inform the design of similar innovations in other resource-limited settings with a high HIV prevalence and a dearth of eye specialists with capacity to diagnose HIV-related retinopathies.

  13. Attention in dichoptic and binocular vision

    NASA Technical Reports Server (NTRS)

    Kimchi, Ruth; Rubin, Yifat; Gopher, Daniel; Raij, David

    1989-01-01

    The ability of human subjected to mobilize attention and cope with task requirements under dichoptic and binocular viewing was investigated in an experiment employing a target search task. Subjects were required to search for a target at either the global level, the local level, or at both levels of a compound stimulus. The tasks were performed in a focused attention condition in which subjects had to attend to the stimulus presented to one eye/field (under dichoptic and binocular viewings, respectively) and to ignore the stimulus presented to the irrelevant eye/field, and in a divided attention condition in which subjects had to attend to the stimuli presented to both eyes/fields. Subjects' performance was affected mainly by attention conditions which interacted with task requirements, rather than by viewing situation. An interesting effect of viewing was found for the local-directed search task in which the cost of dividing attention was higher under binocular than under dichoptic viewing.

  14. Barriers to pilot mobile teleophthalmology in a rural hospital in Southern Malawi

    PubMed Central

    Pérez, Guillermo Martínez; Swart, Wayne; Munyenyembe, Jimmy Kondwani; Saranchuk, Peter

    2014-01-01

    Introduction Malawi has one of the highest HIV prevalences in Sub-Saharan Africa. The rate of eligible HIV-infected people being initiated on antiretroviral therapy (ART) and retained in HIV-care is currently far from adequate. Consequently, many people continue present with advanced immunosuppression at public health facilities, often with undiagnosed opportunistic infections (OIs). Methods In this context, mHealth was the innovation chosen to assist Eye Clinical Officers in early diagnosis of HIV-related diseases having eye manifestations in a rural hospital in Thyolo, Southern Malawi. Results The mTeleophthalmology program began in October 2013, but was stopped prematurely due to organizational and technological barriers that compromised its feasibility. Conclusion Sharing these barriers might be useful to inform the design of similar innovations in other resource-limited settings with a high HIV prevalence and a dearth of eye specialists with capacity to diagnose HIV-related retinopathies. PMID:25767656

  15. Real time chromametry measurement for food quality detection using mobile device

    NASA Astrophysics Data System (ADS)

    Witjaksono, Gunawan; Mohamad Hussin, Nur Haziqah Farah Binti; Abdelkreem Saeed Rabih, Almur; Alfa, Sagir

    2017-09-01

    Freshness of the food is the main factor in determining the quality and safety of the consumed food and hence consumers satisfaction. Current technologies for food quality determination depend on colour changing labels to indicate the freshness level, which is subjective to human eyes. The goal of this paper is to design and develop chromatic algorithm based on RGB colour reading and correlation with pH values for real time determination of freshness level of shrimp. The results show that the developed algorithm is able to measure, analyse and display the freshness level of food directly on the screen of a mobile app technology. The mobile app is developed on Android platform and is tested in the shrimp freshness range by stating whether it is “fresh, good or spoiled”.

  16. A mobile decision support system for red eye diseases diagnosis: experience with medical students.

    PubMed

    López, Marta Manovel; López, Miguel Maldonado; de la Torre Díez, Isabel; Jimeno, José Carlos Pastor; López-Coronado, Miguel

    2016-06-01

    A good primary health care is the base for a better healthcare system. Taking a good decision on time by the primary health care physician could have a huge repercussion. In order to ease the diagnosis task arise the Decision Support Systems (DSS), which offer counselling instead of refresh the medical knowledge, in a profession where it is still learning every day. The implementation of these systems in diseases which are a frequent cause of visit to the doctor like ophthalmologic pathologies are, which affect directly to our quality of life, takes more importance. This paper aims to develop OphthalDSS, a totally new mobile DSS for red eye diseases diagnosis. The main utilities that OphthalDSS offers will be a study guide for medical students and a clinical decision support system for primary care professionals. Other important goal of this paper is to show the user experience results after OphthalDSS being used by medical students of the University of Valladolid. For achieving the main purpose of this research work, a decision algorithm will be developed and implemented by an Android mobile application. Moreover, the Quality of Experience (QoE) has been evaluated by the students through the questions of a short inquiry. The app developed which implements the algorithm OphthalDSS is capable of diagnose more than 30 eye's anterior segment diseases. A total of 67 medical students have evaluated the QoE. The students find the diseases' information presented very valuable, the appearance is adequate, it is always available and they have ever found what they were looking for. Furthermore, the students think that their quality of life has not been improved using the app and they can do the same without using the OphthalDSS app. OphthalDSS is easy to use, which is capable of diagnose more than 30 ocular diseases in addition to be used as a DSS tool as an educational tool at the same time.

  17. Setting targets for human resources for eye health in sub-Saharan Africa: what evidence should be used?

    PubMed

    Courtright, Paul; Mathenge, Wanjiku; Kello, Amir Bedri; Cook, Colin; Kalua, Khumbo; Lewallen, Susan

    2016-03-16

    With a global target set at reducing vision loss by 25% by the year 2019, sub-Saharan Africa with an estimated 4.8 million blind persons will require human resources for eye health (HReH) that need to be available, appropriately skilled, supported, and productive. Targets for HReH are useful for planning, monitoring, and resource mobilization, but they need to be updated and informed by evidence of effectiveness and efficiency. Supporting evidence should take into consideration (1) ever-changing disease-specific issues including the epidemiology, the complexity of diagnosis and treatment, and the technology needed for diagnosis and treatment of each condition; (2) the changing demands for vision-related services of an increasingly urbanized population; and (3) interconnected health system issues that affect productivity and quality. The existing targets for HReH and some of the existing strategies such as task shifting of cataract surgery and trichiasis surgery, as well as the scope of eye care interventions for primary eye care workers, will need to be re-evaluated and re-defined against such evidence or supported by new evidence.

  18. [Social marketing to increase the rate of cataract surgery in the Sava region of Madagascar].

    PubMed

    Nkumbe, H E; Razafinimpanana, N; Rakotondrajoa, L P

    2013-01-01

    Lack of information is one of the main reasons why people who are visually impaired or blind as a result of cataracts do not visit eye care centers for surgery that can restore their sight. This study was conducted to determine the best ways to inform the main target groups about the possibility of restoring sight to those whose visual impairment and blindness is due to cataracts and about outreach visits by the mobile eye clinic of FLM SALFA, Sambava, in the Sava region of Madagascar from November 2008 through October 2009. Two community eye health workers conducted awareness campaigns and delivered posters to radio stations, religious leaders, and administrative authorities of the 17 most populated municipalities in the region of Sava, two weeks before these visits. All participants who visited the mobile clinic were interviewed, and the ophthalmologist's diagnosis was noted on the questionnaire. Women accounted for 51.5% of the 955 participants. Radio was the most effective means of communication in the region overall, and specifically for reaching men (P=0.044); churches were more successful for reaching women (P = 0.000). Cataract was diagnosed in 16.2% of men and 8.1% of women (p = 0.0001). To significantly increase the number of people, especially women, having cataract surgery in the Sava region, it is essential to work closely with the leaders of all religious groups, as well as with radio stations.

  19. Analyzing Cyber-Physical Threats on Robotic Platforms.

    PubMed

    Ahmad Yousef, Khalil M; AlMajali, Anas; Ghalyon, Salah Abu; Dweik, Waleed; Mohd, Bassam J

    2018-05-21

    Robots are increasingly involved in our daily lives. Fundamental to robots are the communication link (or stream) and the applications that connect the robots to their clients or users. Such communication link and applications are usually supported through client/server network connection. This networking system is amenable of being attacked and vulnerable to the security threats. Ensuring security and privacy for robotic platforms is thus critical, as failures and attacks could have devastating consequences. In this paper, we examine several cyber-physical security threats that are unique to the robotic platforms; specifically the communication link and the applications. Threats target integrity, availability and confidential security requirements of the robotic platforms, which use MobileEyes/arnlServer client/server applications. A robot attack tool (RAT) was developed to perform specific security attacks. An impact-oriented approach was adopted to analyze the assessment results of the attacks. Tests and experiments of attacks were conducted in simulation environment and physically on the robot. The simulation environment was based on MobileSim; a software tool for simulating, debugging and experimenting on MobileRobots/ActivMedia platforms and their environments. The robot platform PeopleBot TM was used for physical experiments. The analysis and testing results show that certain attacks were successful at breaching the robot security. Integrity attacks modified commands and manipulated the robot behavior. Availability attacks were able to cause Denial-of-Service (DoS) and the robot was not responsive to MobileEyes commands. Integrity and availability attacks caused sensitive information on the robot to be hijacked. To mitigate security threats, we provide possible mitigation techniques and suggestions to raise awareness of threats on the robotic platforms, especially when the robots are involved in critical missions or applications.

  20. Analyzing Cyber-Physical Threats on Robotic Platforms †

    PubMed Central

    2018-01-01

    Robots are increasingly involved in our daily lives. Fundamental to robots are the communication link (or stream) and the applications that connect the robots to their clients or users. Such communication link and applications are usually supported through client/server network connection. This networking system is amenable of being attacked and vulnerable to the security threats. Ensuring security and privacy for robotic platforms is thus critical, as failures and attacks could have devastating consequences. In this paper, we examine several cyber-physical security threats that are unique to the robotic platforms; specifically the communication link and the applications. Threats target integrity, availability and confidential security requirements of the robotic platforms, which use MobileEyes/arnlServer client/server applications. A robot attack tool (RAT) was developed to perform specific security attacks. An impact-oriented approach was adopted to analyze the assessment results of the attacks. Tests and experiments of attacks were conducted in simulation environment and physically on the robot. The simulation environment was based on MobileSim; a software tool for simulating, debugging and experimenting on MobileRobots/ActivMedia platforms and their environments. The robot platform PeopleBotTM was used for physical experiments. The analysis and testing results show that certain attacks were successful at breaching the robot security. Integrity attacks modified commands and manipulated the robot behavior. Availability attacks were able to cause Denial-of-Service (DoS) and the robot was not responsive to MobileEyes commands. Integrity and availability attacks caused sensitive information on the robot to be hijacked. To mitigate security threats, we provide possible mitigation techniques and suggestions to raise awareness of threats on the robotic platforms, especially when the robots are involved in critical missions or applications. PMID:29883403

Top